WorldWideScience

Sample records for car-borne naitl spectrometry

  1. Car-borne gamma spectrometry: a virtual exercise in emergency response

    DEFF Research Database (Denmark)

    Dowdall, M.; Smethurst, M.A.; Watson, R.

    2012-01-01

    experience in the field however are limited by cost considerations and practicability. These limitations are exacerbated by the fact that field data can differ significantly from data generated in the laboratory. As a means of exercising existing emergency measuring/surveying capability and introducing car......-borne measurements to a larger group, a virtual exercise was devised. The exercise ORPEX (Orphan Sources and Fresh Fallout Virtual Exercise in Mobile Measurement) featured two typical emergency scenarios: a search for orphan sources and surveying to delineate fallout from a local release point. Synthetic spectral...... a local fire involving radioactive material were added to real car-borne data, participants being asked to produce maps identifying and characterising the regions of contamination. Fourteen individual organisations from seven different countries supplied results which indicated that for strong sources...

  2. A Comparison between HPGe and NaI(Tl) detectors performance for gamma-spectrometry of low level measurement

    International Nuclear Information System (INIS)

    Poursiamy, N. H.; Tajikahmadi, H.; Mirshojaei, S. F.

    2005-01-01

    According to progressive usage of nuclear technology, it's important to prevent the contamination of the environment by man-made radioisotopes and exposures of human being. Radioisotopes can enter the human body by inhalation and ingestion which are the most important ways to internal exposures. Measurement of radiation level in foodstuff is one of the most important parameters in environmental safety which is performed according to constitution and standard tests in most countries such as Iran. Gamma spectrometry is carried out by NaI(Tl) and HPGe detector systems for foodstuffs. In this research operation of HPGe and NaI(Tl) detectors in gamma spectrometry with a standard radioactive source are investigated and compared. Also the result of NaI superiority in foodstuff radiation measurement given

  3. The use of car-borne gamma-ray spectrometric survey in a basin

    International Nuclear Information System (INIS)

    Liu Tengyao; Lu Shili; Luo Zongquan.

    1985-01-01

    This paper describes the geological results in a basin in the Inner Mongolia which were obtained by using our newly-developed and assembled car-borne gamma-ray spectrometric system. Combined with the work of regional geology and remote sensing, five relatively favourable uranium zones were located within the working area. The field procedures of car-borne gamma-ray spectrometry for less rigid regions is discussed. The gamma-ray spectrometric profiling is mainly used for regional reconnaissance. In the case of enhanced anomalious radioactivity the profiling with varying directions is adopted and the data are plotted on scale 1:50000 topographic map. It is suggested that the car-borne gamma-ray spectrometric system can be calibrated both by the pads specified for portable spectrometers and by testing site when the calibration facility for the car-borne gamma-ray spectrometric system is not available. The effect of rainfall on car-borne gamma-ray spectrometric survey and the simplified field qualitative determination of U-Ra disequilibrium are also briefly discussed

  4. Evaluation of environmental radiation level by car-borne survey. The outline of the investigation of Aomori Prefecture

    International Nuclear Information System (INIS)

    Hosoda, Masahiro; Inoue, Kazumasa; Oka, Mitsuaki; Omori, Yasutaka; Iwaoka, Kazuki; Tokonami, Shinji

    2016-01-01

    Many nuclear facilities are located in Aomori Prefecture, Japan. However, no detailed dose rate distribution map of Aomori Prefecture, including its mountain regions has been reported since the Fukushima Daiichi Nuclear Power Plant (FDNPP) accident. Thus, a car-borne survey which used a 3-in × 3-in NaI(Tl) scintillation spectrometer was done throughout the prefecture for the purposes of making a dose distribution map and estimating the annual external dose. These results have been published in the same issue of this journal. On the other hand, many researchers have performed car-borne surveys in Fukushima Prefecture after the FDNPP accident. In this paper, the methods of car-borne survey of the present author are explained in detail. 1) The relationship between the total counts per minute of a gamma-ray pulse height distribution and an absorbed dose rate in air is examined for the estimation of dose rate conversion factor. 2) The relationship between count rates outside and inside the car is examined for the estimation of the shielding factor by car body. 3) The uncertainties to the counts inside the car, the dose rate conversion factor and the shielding factor are evaluated according to the Guide to the Expression of Uncertainty in Measurement published by the Joint Committee for Guides in Metrology. 4) The gamma-ray pulse height distributions are unfolded using a 22 × 22 response matrix for the analysis of activity concentrations in soil of "4"0K, "2"3"8U and "2"3"2Th and the contributions of their nuclides to absorbed dose rate in air. 5) The distribution map of absorbed dose rate in air of Aomori Prefecture is drawn using the Generic Mapping Tool which was developed by Hawaii University. (author)

  5. Distribution of gamma-ray dose rate in Fukushima prefecture by a car-borne survey method

    International Nuclear Information System (INIS)

    Sugihara, Shinji; Momoshima, Noriyuki; Maekawa, Akihiro; Ichikawa, Ryohei; Kawamura, Hidehisa

    2013-01-01

    The Tohoku Pacific Earthquake and Tsunami on March 11, 2011, caused severe damage to the TEPCO Fukushima Dai-ichi NPP. This was followed by a nuclear accident at an unprecedented scale, and huge amounts of radioactive material were released into the environment. The distributions of the gamma-ray dose rate in Fukushima prefecture were measured using a NaI(Tl) scintillation survey meter as part of a car-borne survey method on April 18-21, June 20-22, October 18-21, 2011, and on April 9-11 and July 30 - August 1, 2012. The dose rate near TEPCO Fukushima Dai-ichi NPP and at Iitate-mura, Fukushima-city was high (1 to >30 μSv/h). (author)

  6. Handbook on Mobile Gamma-ray Spectrometry

    DEFF Research Database (Denmark)

    Aage, Helle Karina; Korsbech, Uffe C C

    2003-01-01

    Basic physics and mathematics for Airborne and Car-borne Gamma-ray Spectrometry supplemented with practical examples and methods for advanced data processing......Basic physics and mathematics for Airborne and Car-borne Gamma-ray Spectrometry supplemented with practical examples and methods for advanced data processing...

  7. Car-borne and on foot scintillometer survey of the Aegean Sea Islands (Greece). Pt. A

    International Nuclear Information System (INIS)

    Pippos, H.S.

    1984-10-01

    The present report deals with the geological, technical and statistical data of the car-borne scintillometer survey (4,750.7 km) of 38 islands and of the on foot radiometry (87.5 km) of 13 islands of the Aegean Sea. Sixty-nine map sheets (scale 1:50,000) have been covered, corresponding to the total surveyed area of 9,464 km 2 . (author)

  8. A car-borne highly sensitive near-IR diode-laser methane detector

    International Nuclear Information System (INIS)

    Berezin, A G; Ershov, Oleg V; Shapovalov, Yu P

    2003-01-01

    A highly sensitive automated car-borne detector for measuring methane concentration in real time is designed, developed and tested under laboratory and field conditions. Measurements were made with the help of an uncooled tunable near-IR 1.65-μm laser diode. The detector consists of a multipass optical cell with a 45-m long optical path and a base length of 0.5 m. The car-borne detector is intended for monitoring the methane concentration in air from the moving car to reveal the leakage of domestic gas. The sensitivity limit (standard deviation) under field conditions is 1 ppm (20 ppb under laboratory conditions) for a measuring time of 0.4 s. The measuring technique based on the detection of a single methane line ensured a high selectivity of methane detector relative to other gases. The methane detector can be easily modified for measuring other simple-molecule gases (e.g., CO, CO 2 , HF, NO 2 , H 2 O) by replacing the diode laser and varying the parameters of the control program. (special issue devoted to the memory of academician a m prokhorov)

  9. Estimation of the terrestrial gamma-ray levels from car-borne measurements

    International Nuclear Information System (INIS)

    Badran, H.M.

    1998-01-01

    A place to place variation of the gamma-radiation has been measured. The terrestrial gamma-ray levels were obtained with a portable Nal(Tl) detector. Gamma-ray levels were measured inside a car for a distance of about 220 km, from Norman up to Tulsa, Oklahoma, USA. Simultaneous measurements have also been carried out outside the vehicle and at distances 1 m and 5 m from the car. A series of data was collected every 1 mile (∼ 1.6 km). The measurements were also repeated different time under different conditions. The measured car-borne levels were correlated with the outdoor equivalent levels at 1 m above flat ground. The result permits a good estimation of the outdoor gamma-ray levels from the car measurements after the correction due to the vehicle shielding

  10. Car-borne survey measurements with a 3x3` NaI detector

    Energy Technology Data Exchange (ETDEWEB)

    Larsen, E.; Ugletveit, F.; Floe, L.; Mikkelborg, O. [Norwegian Radiation Protection Authority, Oesteraas (Norway)

    1997-12-31

    The Norwegian Radiation Protection Authority (NRPA) took part in the international survey measurement exercise RESUME95 that was arranged in Finland in August 1995. NRPA performed measurements with a simple car-borne measuring system based on standard equipment, a 3x3` NaI detector, an MCA and a GPS connected to a portable PC. The results show substantial variations in dose rate inside areas of a few square kilometres. Spectrum analysis shows that a major part of these differences are caused by variations in deposition of {sup 137}Cs. Our results show that even standard 3x3` NaI detectors can be used for car based survey measurements in fall out situations and search for sources. The detection limits are higher than for larger detectors, but the main limiting factor seem to be the timing capabilities of the acquisition system. (au).

  11. Car-borne survey measurements with a 3x3' NaI detector

    International Nuclear Information System (INIS)

    Larsen, E.; Ugletveit, F.; Floe, L.; Mikkelborg, O.

    1997-01-01

    The Norwegian Radiation Protection Authority (NRPA) took part in the international survey measurement exercise RESUME95 that was arranged in Finland in August 1995. NRPA performed measurements with a simple car-borne measuring system based on standard equipment, a 3x3' NaI detector, an MCA and a GPS connected to a portable PC. The results show substantial variations in dose rate inside areas of a few square kilometres. Spectrum analysis shows that a major part of these differences are caused by variations in deposition of 137 Cs. Our results show that even standard 3x3' NaI detectors can be used for car based survey measurements in fall out situations and search for sources. The detection limits are higher than for larger detectors, but the main limiting factor seem to be the timing capabilities of the acquisition system. (au)

  12. Car-borne survey measurements with a 3x3` NaI detector

    Energy Technology Data Exchange (ETDEWEB)

    Larsen, E; Ugletveit, F; Floe, L; Mikkelborg, O [Norwegian Radiation Protection Authority, Oesteraas (Norway)

    1998-12-31

    The Norwegian Radiation Protection Authority (NRPA) took part in the international survey measurement exercise RESUME95 that was arranged in Finland in August 1995. NRPA performed measurements with a simple car-borne measuring system based on standard equipment, a 3x3` NaI detector, an MCA and a GPS connected to a portable PC. The results show substantial variations in dose rate inside areas of a few square kilometres. Spectrum analysis shows that a major part of these differences are caused by variations in deposition of {sup 137}Cs. Our results show that even standard 3x3` NaI detectors can be used for car based survey measurements in fall out situations and search for sources. The detection limits are higher than for larger detectors, but the main limiting factor seem to be the timing capabilities of the acquisition system. (au).

  13. Car-borne survey of natural background gamma dose rate in Canakkale region (Turkey)

    International Nuclear Information System (INIS)

    Turhan, S.; Arikan, I. H.; Oquz, F.; Aezdemir, T.; Yuecel, B.; Varinlioqlu, A.; Koese, A.

    2012-01-01

    Natural background gamma radiation was measured along roads in the environs of Canakkale region by using a car-borne spectrometer system with a plastic gamma radiation detector. In addition, activity concentrations of 238 U, 226 Ra, 232 Th and 40 K in soil samples from the Canakkale region were determined by using a gamma spectrometer with an HPGe detector. A total of 92 856 data of the background gamma dose rate were collected for the Canakkale region. The background gamma dose rate of the Canakkale region was mapped using ArcGIS software, applying the geostatistical inverse distance-weighted method. The average and population-weighted average of the gamma dose are 55.4 and 40.6 nGy h -1 , respectively. The corresponding average annual effective dose to the public ranged from 26.6 to 96.8 μSv. (authors)

  14. Search for lost or orphan radioactive sources based on Nal gamma spectrometry

    DEFF Research Database (Denmark)

    Aage, Helle Karina; Korsbech, Uffe C C

    2003-01-01

    Within recent decades many radioactive sources have been lost, stolen, or abandoned, and some have caused contamination or irradiation of people. Therefore reliable methods for source recovery are needed. The use of car borne NaI(Tl) detectors is discussed. Standard processing of spectra in general...

  15. Car-borne multichannel gamma-ray spectrometric system model CZD-6

    International Nuclear Information System (INIS)

    Lu Shili; Zhai Yugui; Ma Yanfang; Jiao Cangwen; Zhang Biao

    1998-01-01

    The car-borne multichannel gamma-ray spectrometric system Mode CZD-6 is composed of a HDY-256 of portable multichannel gamma-ray spectrometer developed by the Beijing Research Institute of Uranium Geology and a large volume scintillation detector. the position for each measurement point is determined by the GPS instrument. Its latitude and longitude, as well as measured 256 channels of γ-spectrometric data are collected by a notebook computer, which can show the 256 channels of spectra for each point during measuring processes. The complete system can be loaded in a field car. This system has been used to environmental radioactive monitoring after calibration by airborne radiometric models in Shijiazhuang, Hebei province. A lot of data confirm that the system works stably and reliably, and is a fast and advanced approach for environmental γ-spectrometric monitoring. It can be used not only to determination of contents of natural radioactive elements in environments, but also to monitoring nuclear pollution and emergency treatment in nuclear accidents significantly

  16. Car-borne prospecting methodology. First results from the Cuenca del Nordeste (Uruguay)

    International Nuclear Information System (INIS)

    Goso, H.; Spoturno, J.; Preciozzi, F.

    1976-01-01

    The paper reports on a prospecting procedure used in Uruguay for the selection of areas of interest and on the first results obtained in the Cuenca del Nordeste (North-East Basin). The methodology developed (preliminary radiometric investigation) consists of four successive stages: compilation of material; radiometric survey; statistical analysis; revision of anomalies. The compilation of material has the aim of obtaining geological and cartographic data and of laying out the network of tracks of the area to be prospected. The radiometric survey provides data by means of a car-borne recording scintillometer, together with geological information necessary for preparing the geological map. By statistical analysis of the results it is possible to define and quantify various types of anomalies in a simple manner. Use of a log-normal model yielded a highly logical and coherent approximation in the treatment of the data obtained, and a classification of the defined anomalies in order of importance. Anomaly revision is carried out on first and second order anomalies, and on those of the third order deemed to be significant. This methodology has been developed and is in use on sedimentary formations of the Devonian, Gondwana and Cretaceous, where there are various problems presented by the overburden and the grid size ranges between 1 km and 4-8 km 2 . In the particular case of the Cuenca del Nordeste (Gondwana), with no background of uranium mineralization, it was possible to select a zone of some 1000 km 2 in the San Gregorio-Tres Islas formation with a view to carrying out more detailed work. (author)

  17. Characteristics and verification of a car-borne survey system for dose rates in air: KURAMA-II

    International Nuclear Information System (INIS)

    Tsuda, S.; Yoshida, T.; Tsutsumi, M.; Saito, K.

    2015-01-01

    The car-borne survey system KURAMA-II, developed by the Kyoto University Research Reactor Institute, has been used for air dose rate mapping after the Fukushima Dai-ichi Nuclear Power Plant accident. KURAMA-II consists of a CsI(Tl) scintillation detector, a GPS device, and a control device for data processing. The dose rates monitored by KURAMA-II are based on the G(E) function (spectrum-dose conversion operator), which can precisely calculate dose rates from measured pulse-height distribution even if the energy spectrum changes significantly. The characteristics of KURAMA-II have been investigated with particular consideration to the reliability of the calculated G(E) function, dose rate dependence, statistical fluctuation, angular dependence, and energy dependence. The results indicate that 100 units of KURAMA-II systems have acceptable quality for mass monitoring of dose rates in the environment. - Highlights: • KURAMA-II is a car-borne survey system developed by Kyoto University. • A spectrum-dose conversion operator for KURAMA-II was calculated and examined. • We examined the radiation characteristics of KURAMA-II such as energy dependence. • KURAMA-II has acceptable quality for environmental mass dose rate monitoring

  18. Very low background gamma spectrometer mounted in anti-Compton with NaI(Tl) for the study of glaciers and sediment samples; Spectrometrie gamma a tres bas niveau avec anti-Compton NaI(Tl), pour l`etude des glaciers et des sediments

    Energy Technology Data Exchange (ETDEWEB)

    Pinglot, J.F.; Pourchet, M. [Centre National de la Recherche Scientifique (CNRS), 38 - Grenoble (France). Lab. de Glaciologie

    1994-05-01

    The determination of natural and artificial radioactivities of snow (glaciers, polar ice-caps) or sediment samples (lakes, oceans), takes great benefit with the use of the superior resolution of high purity germanium detector, N type, in a broad energy range( 10 keV up to 1.6 MeV). This detector (relative efficiency: 20%), very low background specified, is mounted in anti-Compton with a 9`x 8` NaI(Tl) scintillator, also with low background. International standards, used with a quantitative software allows the determination of the efficiency curve and the isotopes identification and specific activity. The anti-Compton suppressed spectrometer exhibits a decrease of the background by a factor of ten, without any change in efficiencies. Applications of this spectrometer deal with samples from lake Titicaca and a glacier from Spitsbergen. (authors). 6 figs., 7 refs.

  19. NaI(Tl) electron energy resolution

    CERN Document Server

    Mengesha, W

    2002-01-01

    NaI(Tl) electron energy resolution eta sub e was measured using the Modified Compton Coincidence Technique (MCCT). The MCCT allowed detection of nearly monoenergetic internal electrons resulting from the scattering of incident 662 keV gamma rays within a primary NaI(Tl) detector. Scattered gamma rays were detected using a secondary HPGe detector in a coincidence mode. Measurements were carried out for electron energies ranging from 16 to 438 keV, by varying the scattering angle. Measured HPGe coincidence spectra were deconvolved to determine the scattered energy spectra from the NaI(Tl) detector. Subsequently, the NaI(Tl) electron energy spectra were determined by subtracting the energy of scattered spectra from the incident source energy (662 keV). Using chi-squared minimization, iterative deconvolution of the internal electron energy spectra from the measured NaI(Tl) spectra was then used to determine eta sub e at the electron energy of interest. eta sub e values determined using this technique represent va...

  20. Characterization of Various Survey Meters by Car-borne Survey in Java Island as Basis Data for Searching Orphan Sources

    International Nuclear Information System (INIS)

    Yus Rusdian Akhmad

    2004-01-01

    Recently, an international collaboration in securing and managing radioactive sources, particularly orphan sources, is established. For developing countries such as Indonesia which possesses relatively inadequate resources, an effective approach in dealing with the problem is crucial. In order to deal with this situation, an activity was performed including: 1) assessment of available technical means, 2) car-borne survey during the dry and rainy seasons to identify the impact of Rn daughter washout on the interpretation of search results, 3) search for anomalies in the radioactive exposure map of the Java island, and 4) investigation of anomalies found, using more sophisticated instrument, to detect and secure orphan and illicit radioactive sources. The performance of four selected instruments in a car-borne survey which covers a large area in western part of Java was evaluated. Data series of moving background were divided into two measurement groups; control group and test group. These data series were arranged in, order to determine the value of alarm level. For this purpose, statistic procedures relying on Mann-Whitney U test and a simple moving average test (Moving Background) were applied. Among the four selected survey meters, the most convenient detection system for implementing the activity is Exploranium GR-130. There was little concern on the effect of Rn-daughters washouts on the proposed methods, provided that the operator could recognise the transition period between the clear and rainy weather as it could give rise to false alarm. The Moving Background method was generally superior to Mann-Whitney U test for detecting anomalous radiation level. During the survey, an anomaly in steel industrial area was detected. Using portable gamma spectrometers, it was concluded that the anomaly was generated from naturally occurring radioactive materials (NORM). Analyses upon survey data in the big cities showed anomalies due to concrete structures, especially

  1. Measurement of air dose rates over a wide area around the Fukushima Dai-ichi Nuclear Power Plant through a series of car-borne surveys

    International Nuclear Information System (INIS)

    Andoh, Masaki; Nakahara, Yukio; Tsuda, Shuichi; Yoshida, Tadayoshi; Matsuda, Norihiro; Takahashi, Fumiaki; Mikami, Satoshi; Kinouchi, Nobuyuki; Sato, Tetsuro; Tanigaki, Minoru; Takamiya, Koichi; Sato, Nobuhiro; Okumura, Ryo; Uchihori, Yukio; Saito, Kimiaki

    2015-01-01

    A series of car-borne surveys using the Kyoto University RAdiation MApping (KURAMA) and KURAMA-II survey systems has been conducted over a wide area in eastern Japan since June 2011 to evaluate the distribution of air dose rates around the Fukushima Dai-ichi Nuclear Power Plant and to evaluate the time-dependent trend of decrease in air dose rates. An automated data processing system for the KURAMA-II system was established, which enabled rapid analysis of large amounts of data obtained using about 100 KURAMA-II units. The initial data used for evaluating the migration status of radioactive cesium were obtained in the first survey, followed by other car-borne surveys conducted over more extensive and wider measurement ranges. By comparing the measured air dose rates obtained in each survey (until December 2012), the decreasing trend of air dose rates measured through car-borne surveys was found to be more pronounced than those expected on the basis of the physical decay of radioactive cesium and of the air dose rates measured using NaI (Tl) survey meters in the areas surrounding the roadways. In addition, it was found that the extent of decrease in air dose rates depended on land use, wherein it decreased faster for land used as building sites than for forested areas. - Highlights: • Air dose rates distribution maps were constructed by Car-borne surveys. • KURAMA and KURAMA-II systems have been used for the measurement since 2011. • An automated data processing system for the KURAMA-II system was established. • Decreasing of the dose rates was more pronounced than those of the physical decay. • The dose rates decreased faster for building sites than for forested areas

  2. The application study on the prospecting for gold by car-borne gamma-ray spectrometric method in northern Hebei and other areas

    International Nuclear Information System (INIS)

    Ma Zhongxiang; Liu Tengyao; Zhang Peng; Lu Shili; Zhai Yugui; Ma Yanfang

    1995-01-01

    The prospecting method for gold by car-borne gamma-ray spectrometric survey is a new geophysical and geochemical technique in the search for concealed gold deposits which can be used to effectively predict the regional gold metallogenetic potential area. The method of car-borne gamma-ray spectrometric survey was adopted and 63416 data at gamma-ray spectrometric measuring sites from rock masses (or strata) in northern Hebei and other areas (49100 km 2 ) are obtained. On the basis of the size of geological bodies, the sliding filtering technique was applied to process the gamma-ray spectrometric data from regional geological bodies and maps showing the parameter distribution characteristics were plotted (11 sheets). In accordance with the thorough on the distribution characteristics of gamma-ray spectrometric parameters that reflect the regional geological environment of gold metallogenesis, a set of gamma-ray spectrometric combination parameters in correlation with regional gold metallogenesis has been established and the characteristic information of gamma-ray spectrometric parameters has been extracted. Combined with geological information, the gold metallogenetic geological environment in the working area was studied, and two potential areas were predicted. After verification, gold mineralization was encountered in some areas. The study results show that the car-borne gamma-ray spectrometric method used for regional gold prospecting is a rapid, economical and effective one

  3. Measurement of air dose rates over a wide area around the Fukushima Dai-ichi Nuclear Power Plant through a series of car-borne surveys.

    Science.gov (United States)

    Andoh, Masaki; Nakahara, Yukio; Tsuda, Shuichi; Yoshida, Tadayoshi; Matsuda, Norihiro; Takahashi, Fumiaki; Mikami, Satoshi; Kinouchi, Nobuyuki; Sato, Tetsuro; Tanigaki, Minoru; Takamiya, Koichi; Sato, Nobuhiro; Okumura, Ryo; Uchihori, Yukio; Saito, Kimiaki

    2015-01-01

    A series of car-borne surveys using the Kyoto University RAdiation MApping (KURAMA) and KURAMA-II survey systems has been conducted over a wide area in eastern Japan since June 2011 to evaluate the distribution of air dose rates around the Fukushima Dai-ichi Nuclear Power Plant and to evaluate the time-dependent trend of decrease in air dose rates. An automated data processing system for the KURAMA-II system was established, which enabled rapid analysis of large amounts of data obtained using about 100 KURAMA-II units. The initial data used for evaluating the migration status of radioactive cesium were obtained in the first survey, followed by other car-borne surveys conducted over more extensive and wider measurement ranges. By comparing the measured air dose rates obtained in each survey (until December 2012), the decreasing trend of air dose rates measured through car-borne surveys was found to be more pronounced than those expected on the basis of the physical decay of radioactive cesium and of the air dose rates measured using NaI (Tl) survey meters in the areas surrounding the roadways. In addition, it was found that the extent of decrease in air dose rates depended on land use, wherein it decreased faster for land used as building sites than for forested areas. Copyright © 2014 Elsevier Ltd. All rights reserved.

  4. NaI(Tl) response functions

    International Nuclear Information System (INIS)

    Vega C, H. R.; Ortiz R, J. M.; Benites R, J. L.; De Leon M, H. A.

    2015-09-01

    The response functions of a NaI(Tl) detector have been estimated using Monte Carlo methods. Response functions were calculated for monoenergetic photon sources (0.05 to 3 MeV). Responses were calculated for point-like sources and for sources distributed in Portland cement cylinders. The responses were used to calculate the efficiency functions in term of photon energy. Commonly, sources used for calibration are point-like, and eventually sources to be measured have different features. In order to use the calibrated sources corrections due to solid angle, self-absorption and scattering, must be carried out. However, some of these corrections are not easy to perform. In this work, the calculated responses were used to estimate the detector efficiency of point-like sources, and sources distributed in Portland type cement. Samples of Portland paste were prepared and were exposed to photoneutrons produced by a 15 MV linac. Some of the elements in the cement were activated producing γ-emitting radionuclides that were measured with a NaI(Tl) gamma-ray spectrometer, that was calibrated with point-like sources. In order to determine the specific activity in the induced radioisotopes calculated efficiencies were used to make corrections due to the differences between the solid angle, photon absorption and photon scattering in the point-like calibration sources and the sources distributed in cement. During the interaction between photoneutrons and the cement samples three radioisotopes were induced: 56 Mn, 24 Na, and 28 Al. (Author)

  5. NaI(Tl) response functions

    Energy Technology Data Exchange (ETDEWEB)

    Vega C, H. R.; Ortiz R, J. M. [Universidad Autonoma de Zacatecas, Unidad Academica de Estudios Nucleares, Cipres No. 10, Fracc. La Penuela, 98068 Zacatecas, Zac. (Mexico); Benites R, J. L. [Centro Estatal de Cancerologia de Nayarit, Calz. de la Cruz 118 Sur, Tepic, Nayarit (Mexico); De Leon M, H. A., E-mail: fermineutron@yahoo.com.mx [Instituto Tecnologico de Aguascalientes, Av. Adolfo Lopez Mateos 1801 Ote., 20155 Aguascalientes, Ags. (Mexico)

    2015-09-15

    The response functions of a NaI(Tl) detector have been estimated using Monte Carlo methods. Response functions were calculated for monoenergetic photon sources (0.05 to 3 MeV). Responses were calculated for point-like sources and for sources distributed in Portland cement cylinders. The responses were used to calculate the efficiency functions in term of photon energy. Commonly, sources used for calibration are point-like, and eventually sources to be measured have different features. In order to use the calibrated sources corrections due to solid angle, self-absorption and scattering, must be carried out. However, some of these corrections are not easy to perform. In this work, the calculated responses were used to estimate the detector efficiency of point-like sources, and sources distributed in Portland type cement. Samples of Portland paste were prepared and were exposed to photoneutrons produced by a 15 MV linac. Some of the elements in the cement were activated producing γ-emitting radionuclides that were measured with a NaI(Tl) gamma-ray spectrometer, that was calibrated with point-like sources. In order to determine the specific activity in the induced radioisotopes calculated efficiencies were used to make corrections due to the differences between the solid angle, photon absorption and photon scattering in the point-like calibration sources and the sources distributed in cement. During the interaction between photoneutrons and the cement samples three radioisotopes were induced: {sup 56}Mn, {sup 24}Na, and {sup 28}Al. (Author)

  6. Background studies for NaI(Tl) detectors in the ANAIS dark matter project

    International Nuclear Information System (INIS)

    Amaré, J.; Borjabad, S.; Cebrián, S.; Cuesta, C.; Fortuño, D.; García, E.; Ginestra, C.; Gómez, H.; Martínez, M.; Oliván, M. A.; Ortigoza, Y.; Solórzano, A. Ortiz de; Pobes, C.; Puimedón, J.; Sarsa, M. L.; Villar, J. A.; Villar, P.

    2013-01-01

    Several large NaI(Tl) detectors, produced by different companies, have been operated in the Canfranc Underground Laboratory (LSC) in the frame of the ANAIS (Annual modulation with NaI Scintillators) project devoted to the direct detection of dark matter. A complete background model has been developed for a 9.6 kg detector (referred as ANAIS-0 prototype) after a long data taking at LSC. Activities from the natural chains of 238 U and 232 Th, and 40 K in the NaI(Tl) crystal were evaluated applying different methods: discrimination of alpha particles vs beta/gamma background by Pulse Shape Analysis for quantifying the content of the natural chains and coincidence techniques for 40 K. Radioactive contaminations in the detector and shielding components were also determined by HPGe spectrometry. Monte Carlo simulations using Geant4 package were carried out to evaluate their contribution. At high energies, most of the measured background is nicely reproduced; at low energy some non-explained components are still present, although some plausible background sources have been analyzed. The 40 K content of the NaI(Tl) crystal has been confirmed to be the dominant contributor to the measured background with this detector. In addition, preliminary results of the background characterization, presently underway at the LSC, of two recently produced NaI(Tl) detectors, with 12.5 kg mass each, will be presented: cosmogenic induced activity has been clearly observed and is being quantified, and 40 K activity at a level ten times lower than in ANAIS-0 has been determined

  7. Search for lost or orphan radioactive sources based on NaI gamma spectrometry

    International Nuclear Information System (INIS)

    Aage, H.K.; Korsbech, U.

    2003-01-01

    Within recent decades many radioactive sources have been lost, stolen, or abandoned, and some have caused contamination or irradiation of people. Therefore reliable methods for source recovery are needed. The use of car borne NaI(Tl) detectors is discussed. Standard processing of spectra in general can disclose strong and medium level signals from manmade nuclides. But methods for detecting low level signals from weak, distant or shielded sources can be improved. New methods for source detection and identification based on noise adjusted singular value decomposition and on area specific stripping of spectra are presented

  8. Benchmarking NaI(Tl) Electron Energy Resolution Measurements

    International Nuclear Information System (INIS)

    Mengesha, Wondwosen; Valentine, J D.

    2002-01-01

    A technique for validating electron energy resolution results measured using the modified Compton coincidence technique (MCCT) has been developed. This technique relies on comparing measured gamma-ray energy resolution with calculated values that were determined using the measured electron energy resolution results. These gamma-ray energy resolution calculations were based on Monte Carlo photon transport simulations, the measured NaI(Tl) electron response, a simplified cascade sequence, and the measured electron energy resolution results. To demonstrate this technique, MCCT-measured NaI(Tl) electron energy resolution results were used along with measured gamma-ray energy resolution results from the same NaI(Tl) crystal. Agreement to within 5% was observed for all energies considered between the calculated and measured gamma-ray energy resolution results for the NaI(Tl) crystal characterized. The calculated gamma-ray energy resolution results were also compared with previously published gamma-ray energy resolution measurements with good agreement (<10%). In addition to describing the validation technique that was developed in this study and the results, a brief review of the electron energy resolution measurements made using the MCCT is provided. Based on the results of this study, it is believed that the MCCT-measured electron energy resolution results are reliable. Thus, the MCCT and this validation technique can be used in the future to characterize the electron energy resolution of other scintillators and to determine NaI(Tl) intrinsic energy resolution

  9. Stability of detecting system using NaI(Tl)

    International Nuclear Information System (INIS)

    Zhuo Yunshang; Lei Zhangyun; Zen Yu; Gong Hua

    1996-01-01

    A detecting system using NaI(Tl) is widely used in research and industry of nuclear science and other fields. For providing the high accuracy and working well under inclement environment, the stability of detecting system using NaI(Tl) is very important. The variation of environment temperature, the change of counting rate and long time continuous working of detector will cause un-negligible effect on the measurement. Three approaches were used. They are: 1) temperature control (It makes the effect of the variation of environment temperature on the measurement negligible.); 2) spectrum stabilizing (It adjust the peak position of the spectrum when the counting rate changes.); and 3) auto-checking and adjusting (It adjusts the drift of the NaI(Tl) detecting system when it works continuously)

  10. Portable in situ NaI(Tl) γ spectroscopy system

    International Nuclear Information System (INIS)

    Wang Bairong; Dong Binjiang; Zeng Liping; Shen Tingyun

    2000-01-01

    The author describes a portable in situ NaI(Tl) γ spectroscopy system, which consists of a NaI (Tl) scintillation detector, an integrative spectroscopy card, a notebook computer and spectroscopy software. The spectrometer addresses applications in environmental or nuclear accident in situ γ spectroscopy measurements, and gives valid quantitative results of radionuclide concentrations per unit volume (Bq/kg) or unit area (Bq/cm 2 ) in the soil and absorbed dose rate in air at 1 m above ground (Gy/h)

  11. Towards the use of small amounts of activated charcoal along with well-type NaI(Tl) detector for indoor radon measurements

    International Nuclear Information System (INIS)

    Al-Azmi, D.

    2006-01-01

    The feasibility of using small quantities of activated charcoal and a 7.6 cm x 7.6 cm NaI(Tl) well-type detector was investigated for indoor radon measurements. Vials, filled with 10 g of charcoal, were exposed for different indoor radon concentration levels typical of Kuwait dwellings. After exposure, the vials were sealed and kept for 3 h to allow radon to come into radioactive equilibrium with its progenies and were then analysed by gamma-ray spectrometry using the well-type NaI(Tl) detector. The variation of radon absorption by the vials filled with charcoal with exposure time was also studied. A comparative study of the present technique with the standard technique of using 70 g charcoal canisters and flat NaI detector was also performed. After establishing the suitability of the technique, the charcoal vials were then used to investigate the effect of air-ventilation on the concentration levels of the indoor radon. Results show that there is a reduction in the radon concentration level (up to 25%) when the air-ventilation system was switched on. The paper presents the results of the study on the feasibility of combining small amounts of activated charcoal with a well-type NaI(Tl) detector in the measurement of indoor radon concentrations. (authors)

  12. Determination of the full energy peak efficiency of NaI(Tl) detectors

    International Nuclear Information System (INIS)

    Cesana, A.; Terrani, M.

    1978-01-01

    A simple procedure for the accurate evaluation of the full energy peak efficiency of NaI(Tl) crystals is described. Particular attention is given to the peak to total ratio determination for which a new method is proposed. (author)

  13. Statistical data evaluation in mobile gamma spectrometry. An optimisation of on-line search strategies in the scenario of lost point sources

    International Nuclear Information System (INIS)

    Hjerpe, T.; Samuelsson, C.

    1999-01-01

    There is a potential risk that hazardous radioactive sources could enter the environment, e.g. via satellite debris, smuggled radioactive goods or lost metal scrap. From a radiation protection point of view there is a need for rapid and reliable methods for locating and identifying sources. Car-borne and air-borne detector systems are suitable for the task. The condition in this work is a situation where the missing radionuclide is known, which is not an unlikely scenario. The possibility that the source is located near a road can be high, and thus motivating a car-borne spectrometer system. The main object is to optimise on-line statistical methods in order to achieve a high probability for locating point sources, or hot spots, and still have reasonably few false alarms from variations in the natural background radiation. Data were obtained from a car-borne 3 litres (NaI(Tl) detector and two point sources, located at various distances from the road. The nuclides used were 137 Cs and 131 I. Spectra were measured stationary on the road. From these measurements spectra we have reconstructed spectra applicable to different speed and sampling times; the time 3 seconds and 50 km/h are used in this work. The maximum distance a source can be located from the road and still be detected is estimated with four different statistical analysis methods. This distance is called the detection distance, DD. The method is applied on gross counts in the full energy peak window. For each method alarm thresholds has been calculated from background data obtained in Scania (Skaane), in the south of Sweden. The results show a 30-50% difference in DD's. With this semi-theoretical approach, the two sources could be detected from 250 m ( 137 Cs, 6GBq) and 200 m ( 131 I, 4GBq). (au)

  14. Development of NaI(Tl) scintillating films for imaging soft x-rays

    International Nuclear Information System (INIS)

    Shepherd, J.A.

    1993-01-01

    Thin film NaI(Tl) scintillators, of areas of up to 130 cm 2 , have been fabricated and characterized for use on soft x-ray imaging photomultiplier tubes. Relevant parameters of photon-counting imaging detectors are defined and used to predict the performance of several materials, including CsI(Na), CsI(Tl), CaF 2 (Eu), Lu 2 (SiO 4 )O:Ce, and NaI(Tl), as thin film scintillators on fiber optic substrates. Also, x-ray imaging methodologies are compared. The NaI(Tl) films were vapor-deposited onto quartz and fiber optic substrates using a powder flash deposition technique. When compared to single crystal NaI(Tl), the films were found to have equally high light yield but lower energy resolution. Light yield optimization was studied in detail including the effects of substrate temperature, activator concentration in the evaporant, and boat temperature. Spatial resolution as well as parallax errors are discussed and measured for film thicknesses up to 61 μm. A technique is described that can substantially increase the light collection of high index films on fiber optic disks. The light collection was improved by 20% by coating the disk with potassium silicate before the NaI(Tl) deposition. Large area films, up to 130 cm 2 , had a spatial uniformity of response within ±1.5% for count rate and ±3.5% for light yield, and their spatial resolution exceeded 16.6 lp mm -1 when deposited onto fiber optic substrates. The 8-keV x-ray detection efficiency of the microchannel plate imaging photomultiplier tube coupled to a NaI(Tl) film scintillator is predicted to be 88%. Other uses for the films are also described

  15. A portable in situ NaI(Tl) γ spectroscopy system

    International Nuclear Information System (INIS)

    Wang Bairong; Dong Binjiang; Zeng Liping

    1999-01-01

    The author describes a portable in situ NaI(Tl) γ spectroscopy system, which consists of a NaI(Tl) scintillation detector, an integrative spectroscopy card, a notebook computer and the spectroscopy software. The spectrometer addresses applications in environmental or nuclear accident in situ γ spectroscopy measurements, and gives valid quantitative results of radionuclide concentrations per unit volume (Bq/kg) or per unit area (Bq/cm 2 ) in the soil and absorbed dose rate in air 1 m above ground (Gy/h)

  16. The unfolding of NaI(Tl) γ-ray spectrum based on maximum likelihood method

    International Nuclear Information System (INIS)

    Zhang Qingxian; Ge Liangquan; Gu Yi; Zeng Guoqiang; Lin Yanchang; Wang Guangxi

    2011-01-01

    NaI(Tl) detectors, having a good detection efficiency, are used to detect gamma rays in field surveys. But the poor energy resolution hinders their applications, despite the use of traditional methods to resolve the overlapped gamma-ray peaks. In this paper, the maximum likelihood (ML) solution is used to resolve the spectrum. The ML method,which is capable of decomposing the peaks in energy difference of over 2/3 FWHM, is applied to scale NaI(Tl) the spectrometer. The result shows that the net area is in proportion to the content of isotopes and the precision of scaling is better than the stripping ration method. (authors)

  17. Evaluation of 1cm dose equivalent rate using a NaI(Tl) scintilation spectrometer

    International Nuclear Information System (INIS)

    Matsuda, Hideharu

    1990-01-01

    A method for evaluating 1 cm dose equivalent rates from a pulse height distribution obtained by a 76.2mmφ spherical NaI(Tl) scintillation spectrometer was described. Weak leakage radiation from nuclear facilities were also measured and dose equivalent conversion factor and effective energy of leakage radiation were evaluated from 1 cm dose equivalent rate and exposure rate. (author)

  18. Study of the functional characteristics of a NaI(Tl) scintillator gamma spectrometer

    International Nuclear Information System (INIS)

    Jesus Barbosa, S. de.

    1983-01-01

    Functional characteristics (resolution, stability, linearity, counting efficiency) of a NaI(Tl) scintillator gamma spectrometer were studied. Diagrams were plotted and several standard sources ( 241 Am, 109 Cd, 57 Co, 137 Cs, 54 Mn, 22 Na) with gamma energies ranging from 60 to 1275 KeV were used. (C.L.B.) [pt

  19. Implementation of a laboratory apparatus based on a NaI(Tl) spectrometer: application to the characterization of soil radioactivity

    International Nuclear Information System (INIS)

    Andrianjafitrimo

    2001-01-01

    A laboratory apparatus based on a NaI(Tl) γ-ray spectrometer for the assessment of radionuclides naturally occurring in environmental samples was established. This detection system is devoted to the quantitative determination of uranium, thorium and potassium in soils and rocks samples.The IAEA reference materials, RG S ET was used for calibration of the spectrometer. The photopics at 1460, 1765 and 2614 keV due to 40 K, 238 U and 232 Th, respectively, were used for the corresponding activity measurements. The radioactivity characterization of soils was performed on primordial radionuclides distribution and radon emanation according to the grain-size. Because of social and economical interest that present the collected samples (mineralized sands and soils rich in uranium), their radiation protection aspects was considered in this work. Discussions was made on factors restricting the approach based on scintillation spectrometry, such as radioactive equilibrium and radon encapsulation in the one hand, and in the other hand, on the assessment of soils characterization, among other things, grain-size effects. The present work has also shown that radioactivity levels of building and fabrication materials can be reduced by the removal of fines or fraction having higher concentrations by sieving. [fr

  20. Design and performance of a modularized NaI(Tl) detector (the crystal ball prototype)

    International Nuclear Information System (INIS)

    Chan, Y.; Partridge, R.A.; Peck, C.W.

    1977-01-01

    A prototype NaI(Tl) detector (the Cluster of 54) of spherical geometry subtending a solid angle of 7.5 percent of 4π at its center, has recently been assembled and tested. This detector consisted of 54 close-packed but optically isolated NaI(Tl) modules and the associated electronic circuitry. The Cluster of 54 is the predecessor of an almost complete spherical detector, the Crystal Ball, which will cover 94 percent of 4π. The latter detector is now under construction and is especially designed for the study of γ-rays produced in electron-positron collisions at colliding beam facilities. The mechanical, optical, and electronic assembly of the prototype system is outlined. Cluster of 54 test data will be presented

  1. Simulation of the peak efficiency for a stacked NaI(Tl) spectrometer

    Energy Technology Data Exchange (ETDEWEB)

    Yoshida, H; Murohka, H; Anami, K; Nohtomi, A; Uozumi, Y; Sakae, T; Matoba, M [Kyushu Univ., Fukuoka (Japan). Faculty of Engineering; Koori, N; Maki, T

    1996-07-01

    A stacked NaI(Tl) spectrometer has been developed to measure proton spectra in wide energy range. In the measurement of charged particles with intermediate energy, the detecting efficiency of the spectrometer decreases considerably due to nuclear reactions or out-scattering in the detector material. A Monte Carlo simulation code has been developed to estimate the peak efficiency (peak-to-total ratio) of the spectrometer. The calculated efficiency for intermediate energy is in good agreement with the experimental one. (author)

  2. Technology for computer-stabilized peak of NaI(Tl) gamma spectrum

    International Nuclear Information System (INIS)

    Chen Jianzhen; Guo Lanying; Ling Qiu; Qu Guopu; Zhao Lihong; Hu Chuangye

    2005-01-01

    An improved technology for spectrum stabilization of NaI(Tl) gamma spectrum was introduced. This technology is based on the system using a reference peak, which is equivalent gamma peak of 241 Am source. The computer seeks peak's position deviation and computes adjust value of programmable amplifier and controls programmable amplifier to stabilize spectrum by digital PID. This is a technology of spectrum stabilizing with 'hardware + reference-peak + software' and has high stability and fast speed of spectrum stabilizing. (author)

  3. Understanding NaI(Tl) crystal background for dark matter searches

    Energy Technology Data Exchange (ETDEWEB)

    Adhikari, G.; Adhikari, P.; Kong, S.Y.; Oh, S.Y. [Sejong University, Department of Physics and Astronomy, Seoul (Korea, Republic of); Ha, C.; Jeon, E.J.; Kim, N.Y.; Lee, H.S.; Park, J.S.; Park, K.S. [Institute for Basic Science (IBS), Center for Underground Physics, Daejeon (Korea, Republic of); Kim, Y.D. [Institute for Basic Science (IBS), Center for Underground Physics, Daejeon (Korea, Republic of); Sejong University, Department of Physics and Astronomy, Seoul (Korea, Republic of)

    2017-07-15

    We have developed ultra-low-background NaI(Tl) crystals to reproduce the DAMA results with the ultimate goal of achieving purity levels that are comparable to or better than those of the DAMA/LIBRA crystals. Even though the achieved background level does not approach that of DAMA/LIBRA, it is crucial to have a quantitative understanding of the backgrounds. We have studied background simulations toward a deeper understanding of the backgrounds and developed background models for a 9.16-kg NaI(Tl) crystal used in the test arrangement. In this paper we describe the contributions of background sources quantitatively by performing Geant4 Monte Carlo simulations that are fitted to the measured data to quantify the unknown fractions of the background compositions. In the fitted results, the overall simulated background spectrum well describes the measured data with a 9.16-kg NaI(Tl) crystal and shows that the background sources are dominated by surface {sup 210}Pb and internal {sup 40}K in the 2-6-keV energy interval, which produce 2.4 counts/day/keV/kg (dru) and 0.5 dru, respectively. (orig.)

  4. Pulse-shape discrimination between electron and nuclear recoils in a NaI(Tl) crystal

    Energy Technology Data Exchange (ETDEWEB)

    Lee, H.S. [Department of Physics, Ewha Womans University,Seoul 120-750 (Korea, Republic of); Adhikari, G.; Adhikari, P. [Department of Physics, Sejong University,Seoul 143-747 (Korea, Republic of); Choi, S. [Department of Physics and Astronomy, Seoul National University,Seoul 151-747 (Korea, Republic of); Hahn, I.S. [Department of Science Education, Ewha Womans University,Seoul 120-750 (Korea, Republic of)

    2015-08-18

    We report on the response of a high light-output NaI(Tl) crystal to nuclear recoils induced by neutrons from an Am-Be source and compare the results with the response to electron recoils produced by Compton-scattered 662 keV γ-rays from a {sup 137}Cs source. The measured pulse-shape discrimination (PSD) power of the NaI(Tl) crystal is found to be significantly improved because of the high light output of the NaI(Tl) detector. We quantify the PSD power with a quality factor and estimate the sensitivity to the interaction rate for weakly interacting massive particles (WIMPs) with nucleons, and the result is compared with the annual modulation amplitude observed by the DAMA/LIBRA experiment. The sensitivity to spin-independent WIMP-nucleon interactions based on 100 kg⋅year of data from NaI detectors is estimated with simulated experiments, using the standard halo model.

  5. Pulse-shape discrimination between electron and nuclear recoils in a NaI(Tl) crystal

    International Nuclear Information System (INIS)

    Lee, H.S.; Adhikari, G.; Adhikari, P.; Choi, S.; Hahn, I.S.

    2015-01-01

    We report on the response of a high light-output NaI(Tl) crystal to nuclear recoils induced by neutrons from an Am-Be source and compare the results with the response to electron recoils produced by Compton-scattered 662 keV γ-rays from a 137 Cs source. The measured pulse-shape discrimination (PSD) power of the NaI(Tl) crystal is found to be significantly improved because of the high light output of the NaI(Tl) detector. We quantify the PSD power with a quality factor and estimate the sensitivity to the interaction rate for weakly interacting massive particles (WIMPs) with nucleons, and the result is compared with the annual modulation amplitude observed by the DAMA/LIBRA experiment. The sensitivity to spin-independent WIMP-nucleon interactions based on 100 kg⋅year of data from NaI detectors is estimated with simulated experiments, using the standard halo model.

  6. The nonlinear light output of NaI(Tl) detectors in the Modular Total Absorption Spectrometer

    Energy Technology Data Exchange (ETDEWEB)

    Rasco, B.C., E-mail: crasco@lsu.edu [Department of Physics and Astronomy, Louisiana State University, Baton Rouge, LA 70803 (United States); Fijałkowska, A.; Karny, M. [Faculty of Physics, University of Warsaw, Pasteura 5, PL-02093 Warszawa (Poland); Rykaczewski, K.P. [Physics Division, Oak Ridge National Laboratory, Oak Ridge, TN 37831 (United States); Wolińska-Cichocka, M. [Physics Division, Oak Ridge National Laboratory, Oak Ridge, TN 37831 (United States); Oak Ridge Associated Universities, Oak Ridge, TN 37831 (United States); Heavy Ion Laboratory, University of Warsaw, Warsaw PL-02-093 (Poland); Grzywacz, R.; Goetz, K.C. [Department of Physics and Astronomy, University of Tennessee, Knoxville, TN 37966 (United States)

    2015-07-11

    A new detector array, the Modular Total Absorption Spectrometer (MTAS), was commissioned at the Holifield Radioactive Ion Beam Facility (HRIBF) at Oak Ridge National Lab (ORNL). Total absorption gamma spectra measured with MTAS are expected to improve beta-feeding patterns and beta strength functions in fission products. MTAS is constructed out of hexagonal NaI(Tl) detectors with a unique central module surrounded by 18 identical crystals assembled in three rings. The total NaI(Tl) mass of MTAS is over 1000 kg. The response of the central and other 18 MTAS modules to γ-radiation was simulated using the GEANT4 toolkit modified to analyze the nonlinear light output of NaI(Tl). A detailed description of the GEANT4 modifications made is discussed. Simulated energy resolution of MTAS modules is found to agree well with the measurements for single γ transitions of 662 keV ({sup 137}Cs) with 8.2% full width half maximum (FWHM), 835 keV ({sup 54}Mn) with FWHM of 7.5% FWHM, and 1115 keV ({sup 65}Zn) with FWHM of 6.5%. Simulations of single and multiple γ-rays from {sup 60}Co are also discussed.

  7. Application of NaI(Tl) scintillation detector to measurement of tritium concentration

    International Nuclear Information System (INIS)

    Nishizawa, Kazushige; Endo, Yoshio; Shinagawa, Mutsuaki

    1977-01-01

    Measurements of tritium concentration in various media have been successfully performed by detecting with an ordinary NaI(Tl) scintillation counter the bremsstrahlung emitted from tritium decay. To distinguish meaningful signals from noises emanating mainly from thermoelectrons present in the phototube, differences in rise time were discriminated by means of an electronic circuit, instead of separation by pulse height analysis. This pulse-shape discriminator successfully reduced noise counts below 18 keV in a multichannel analyzer from 100 cpm to 4 cpm, which permitted direct counting of tritiated water as dilute as 1 μCi/ml, without requiring any complicated preparation. (auth.)

  8. Scintillation efficiency measurement of Na recoils in NaI(Tl) below the DAMA/LIBRA energy threshold

    Energy Technology Data Exchange (ETDEWEB)

    Xu, Jingke; Shields, Emily; Calaprice, Frank; Westerdale, Shawn; Froborg, Francis; Suerfu, Burkhant; Alexander, Thomas; Aprahamian, Ani; Back, Henning O.; Casarella, Clark; Fang, Xiao; Gupta, Yogesh K.; Ianni, Aldo; Lamere, Edward; Lippincott, W. Hugh; Liu, Qian; Lyons, Stephanie; Siegl, Kevin; Smith, Mallory; Tan, Wanpeng; Kolk, Bryant Vande

    2015-07-01

    The dark matter interpretation of the DAMA modulation signal depends on the NaI(Tl) scintillation efficiency of nuclear recoils. Previous measurements for Na recoils have large discrepancies, especially in the DAMA/LIBRA modulation energy region. We report a quenching effect measurement of Na recoils in NaI(Tl) from 3 to 52 keVnr, covering the whole DAMA/LIBRA energy region for dark matter-Na scattering interpretations. By using a low-energy, pulsed neutron beam, a double time-of-flight technique, and pulse-shape discrimination methods, we obtained the most accurate measurement of this kind for NaI(Tl) to date. The results differ significantly from the DAMA reported values at low energies but fall between the other previous measurements. We present the implications of the new quenching results for the dark matter interpretation of the DAMA modulation signal.

  9. Development of low background CsI(Tl) and NaI(Tl) crystals for WIMP search

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Hyun Su [Department of Physics, Ewha Womans University, Seoul 120-750 (Korea, Republic of)

    2015-08-17

    We have developed low background CsI(Tl) and NaI(Tl) crystals to search for weakly interacting massive particles as well as to verify the origin of the annual modulation signal observed by the DAMA/LIBRA experiment. Extensive studies about the contamination mechanisim of {sup 137}Cs in CsI powder lead to the growth of ultra-low-background CsI(Tl) crystals. Similar approaches for NaI(Tl) crystals have been applied to reduce internal backgrounds to less than 0.5 counts/kg/day/keV. Status and understanding of backgrounds and background reduction in NaI(Tl) crystals will be discussed.

  10. Gamma spectra analysis from a NaI(Tl) scintillation detector using a micro-computer

    International Nuclear Information System (INIS)

    Levinson, S.

    1990-01-01

    A software package of programs was devloped for qualitative and quantitative evaluation of gamma ray spectra obtained from a NaI(Tl) scintilation counter, by means of a micro-computer. The programs can easily be transformed for use with a Ge(Li) detector. The various algorithms enable automatic analyzing of a spectrum and also interactive or manual mode. The graphic programs display the measured spectrum as well as spectra of standard radionuclides which helps in the determination of peaks and related radionuclides in the spectrum. The peak search is carried out on a smoothed spectrum and is done by checking the behaviour of the second and third derivatives. The algorithm solves the problem of overlapping peaks and performs gaussian fitting, if necessary. Determination of the various radionuclides in the spectrum is done by linear minimum least squares techniques. Overall analysis of the radionuclides activities in the spectrum is obtained for samples of various counting geometries. In addition, a model was developed for efficiency calibration of flat 3X3 inch NaI(Tl) detectors for different samples measured in various counting geometries. It is based on point source experimental efficiency curve fitting. (author)

  11. Pulse shaper for scintillation detectors with NaI(Tl) or CsI(Tl) crystals

    International Nuclear Information System (INIS)

    Novisov, B.S.; Maksimenko, A.S.; Baryshev, A.V.; Zhukov, A.V.

    1978-01-01

    The basic circuit of a signal shaper for scintillation detectors with NaI(Tl) and CsI(Tl) crystals is described. To increase amplitude resolution, it is suggested to integrate not the whole charge at the photomultiplier output, but a part of the charge during the initial 100 ns of the current pulse; the remaining part of the current signal is compensated directly at the photomultiplier anode by means of an electric circuit. The principal elements of the spectrometric signal shaper include an input transistor amplifier, a compensation circuit, a key element, a shaper amplifier of time pulses, a shaper of signal duration for controlling the key element, and an output spectrometric amplifier. This device, being used, one can shape pulses at durations of 100 ns and more. The shaper restoration time does not exceed 50 ns. When the shaper operates with NaI(Tl) crystals and at counting rate of 10 6 pulse/s, the amplitude resolution with and without the compensation circuit is 17% and 21% respectively

  12. Response function of NaI(Tl) detectors and multiple backscattering of gamma rays in aluminium

    International Nuclear Information System (INIS)

    Sabharwal, Arvind D.; Singh, Manpreet; Singh, Bhajan; Sandhu, B.S.

    2008-01-01

    The response function, converting the observed pulse-height distribution of a NaI(Tl) detector to a true photon spectrum, is obtained experimentally with the help of an inverse matrix approach. The energy of gamma-ray photons continuously decreases as the number of scatterings increases in a sample having finite dimensions when one deals with the depth of the sample. The present experiments are undertaken to study the effect of target thickness on intensity distribution of gamma photons multiply backscattered from an aluminium target. A NaI(Tl) gamma-ray detector detects the photons backscattered from the aluminium target. The subtraction of analytically estimated singly scattered distribution from the observed intensity distribution (originating from interactions of primary gamma-ray photons with the target) results in multiply backscattered events. We observe that for each incident gamma photon energy, the number of multiply backscattered photons increases with increase in target thickness and then saturates at a particular target thickness called the saturation thickness (depth). Saturation thickness for multiply backscattering of gamma photons is found to decrease with increase in energy of incident gamma-ray photons

  13. Computerized operation of a multi detector spectrometry system

    Energy Technology Data Exchange (ETDEWEB)

    Levinson, S; Messing, M; Gilad, Y; Ballon, I; Peled, O; German, U [Israel Atomic Energy Commission, Beersheba (Israel). Nuclear Research Center-Negev

    1996-12-01

    A spectrometry System consisting of a PCA-II (Personal Computer Analyzer) and a DEAR (Digital Mixer Router) of Nucleus Inc. is operated to collect spectra from 8 NaI(Tl) detectors. As most of the functions including calibration, counting and data handling are similar for all the detectors, the option of automatic tasks is a natural choice. An external computer program which controls tile operation and data handling of tile 8 spectrometer system was developed (authors).

  14. Comparison measure of natural radioactivity in environment specimen using HPGe and NaI(Tl) γ-ray spectrometer

    International Nuclear Information System (INIS)

    Zhou Chunlin; Han Feng; Li Tiantuo; Ma Wenyan; Di Yuming; Guo Huiping; Wu Yuelei

    2000-01-01

    The author reports the comparison results on natural radioactive nuclide contents of soil specimen from an uranium diggings with HPGe and NaI(Tl) γ-ray spectrometer. Relative method and athwart matrix method are used to analyze natural radioactive nuclide contents in samples of soil. The results are compared and are proven to be in accordance with each other

  15. Monte Carlo calculation of the photo-fraction R(E) of NaI(Tl) scintillation spectrometer

    CERN Document Server

    Guo Chun Ying; Lin Yuan Ge

    2002-01-01

    The detecting principle of NaI(Tl) scintillation spectrometer is briefly analysed and the photo-fraction of the spectrometer to various point sources is calculated by using the MCNP code. Besides, comparison of the calculated results with experiment data available is made, and the reason why the calculated results are usually higher is also given

  16. Pulse-shape discrimination of high-energy neutrons and gamma rays in NaI(Tl)

    International Nuclear Information System (INIS)

    Share, G.H.; Kurfess, J.D.; Theus, R.B.

    1978-01-01

    Pulse-shape discrimination can be used to separate neutron and gamma-ray interactions depositing energies up to in excess of 50 MeV in NaI(Tl) crystals. The secondary alpha particles, deuterons and protons produced in the neutron interactions are also resolvable. (Auth.)

  17. Characterization and analysis of NaI(Tl) and BGO detectors

    International Nuclear Information System (INIS)

    Harrison, J.R.

    1994-01-01

    There have been many studies concerning the performance characteristics of NaI(Tl) and BGO scintillating crystals, most of which generate data by algorithms rather than from experimentation. Those studies which do deal with collected data, however, usually test only a few detecting units. It was, therefore, the purpose of this project to develop a characterization method and to characterize a large number of scintillators of various sizes and histories as well as to create a performance profile based on the data collected. The energy ranges at which the detectors show relatively good resolution % and photo peak efficiency was also desired for future reference. Enough statistical data was collected and analyzed so that a differentiation between those detectors which perform well and those that do not can be made

  18. Detection limits of the NaI(Tl) shielded HPGe spectrometer

    International Nuclear Information System (INIS)

    Bikit, I.; Slivka, J.; Krmar, M.; Durcic, Z.; Zikic, N.; Conkic, Lj.; Veskovic, M.; Anicin, I.

    1999-01-01

    The results of a detailed study of the low-level performance of a NaI(Tl) shield added to an iron shielded HPGe spectrometer are presented. Both the 'slow' and the 'fast' anticoincidence gating modes were tested, the 'slow' mode being found better suited for general low-level spectroscopy applications. In long runs the stability of the system in this mode is satisfactory. The anticoincidence action of the NaI(T1) shield lowers the integral background of the iron shielded HPGe detector in the energy range from 30 keV to 2 MeV by a factor of 6.5, and suppresses the continuum above 150 keV by a factor larger than 10

  19. Study of the cosmogenic activation in NaI(Tl) crystals within the ANAIS experiment

    Science.gov (United States)

    Villar, P.; Amaré, J.; Cebrián, S.; Coarasa, I.; García, E.; Martínez, M.; Oliván, M. A.; Ortigoza, Y.; Ortiz de Solórzano, A.; Puimedón, J.; Sarsa, M. L.; Villar, J. A.

    2018-03-01

    The direct detection of galactic dark matter particles requires ultra-low background conditions. NaI(Tl) crystals are applied in the search for these dark matter particles through their interactions in the detector by measuring the scintillation signal produced. The production of long-lived isotopes in materials due to the exposure to cosmic rays on Earth’s surface can be an hazard for these ultra-low background demanding experiments, typically performed underground. Therefore, production rates of cosmogenic isotopes in all the materials present in the experimental set-up, as well as the corresponding cosmic rays exposure history, must be both well-known in order to assess the relevance of this effect in the achievable sensitivity of a given experiment. Here, analysis of the cosmogenic studies developed from the ANAIS experiment NaI(Tl) detectors are presented. Installed inside a convenient shielding at the Canfranc Underground Laboratory just after finishing surface exposure to cosmic rays and thanks to the prompt data taking developed, identification and quantification of isotopes with half-lives of the order of tens of days were allowed, and thanks to the long-term operation of the detectors long-lived isotopes have been also identified and quantified. Main results for the activation yields of iodine and tellurium isotopes, 22Na, 113Sn, 109Cd, and tritium are presented in this work, together with the estimate of the production rates for their activation by cosmic nucleons while on Earth’s surface based on a selection of excitation functions over the entire energy range of cosmic nucleons.

  20. SiPM-MAROC gamma-camera prototype with monolithic NaI(Tl) scintillator

    Energy Technology Data Exchange (ETDEWEB)

    Philippov, Dmitry; Ilyin, Andrey; Belyaev, Vladimir; Popova, Elan [National Research Nuclear University, Moscow Engineering Physics Institute (Russian Federation); Buzhan, Pavel; Stifutkin, Alexei [Moscow Engineering Physics Institute (Russian Federation)

    2015-05-18

    A full-body gamma-camera based on SiPM readout is currently under development as a part of MEPHI R activity supported in the framework of Russian Megagrants program. A goal of this development is a fast upgrade of existing medical equipment with minor changes in a system design and construction in order to combine SPECT and MR instruments. A monolithic NaI(Tl) scintillator commonly used for conventional PMT-based gamma cameras has been chosen for this study. SiPMs will be coupled with the scintillator via an optical guide. To cover scintillator surface thousands of SiPMs are required, together with multichannel front-end electronics. That means that readout electronics have to be very compact, with low power consumption and low cost. 64 – channel ASIC MAROC from Weeroc provides individual readout of each SiPM and has been considered as the best choice among electronics solutions available on the market. As the photodetector parameters are the key issues here, KETEK SiPMs with high detection efficiency, low crosstalk and low noise have been chosen for this study. In order to study the proposed detection system in detail and obtain detector module parameters, required for MC simulation, a 64-channel small prototype with 6x6mm{sup 2} SiPMs has been constructed and tested. SiPMs in SMD packages have been assembled as a matrix of 8x8 elements and readout by MAROC-based board. Prototype has been tested with different shape NaI(Tl) scintillators and gammas with different energy. Dedicated algorithms for extraction of gamma-event’s energy and position are under development. They are based on fitting a matrix of individual SiPMs responses by an analytical function F(x,y). They will be tested with GEANT-simulated events and experimental data. Development of the next (engineering) prototype of SiPM’s module for gamma-camera will be started soon.

  1. SiPM-MAROC gamma-camera prototype with monolithic NaI(Tl) scintillator

    International Nuclear Information System (INIS)

    Philippov, Dmitry; Ilyin, Andrey; Belyaev, Vladimir; Popova, Elan; Buzhan, Pavel; Stifutkin, Alexei

    2015-01-01

    A full-body gamma-camera based on SiPM readout is currently under development as a part of MEPHI R activity supported in the framework of Russian Megagrants program. A goal of this development is a fast upgrade of existing medical equipment with minor changes in a system design and construction in order to combine SPECT and MR instruments. A monolithic NaI(Tl) scintillator commonly used for conventional PMT-based gamma cameras has been chosen for this study. SiPMs will be coupled with the scintillator via an optical guide. To cover scintillator surface thousands of SiPMs are required, together with multichannel front-end electronics. That means that readout electronics have to be very compact, with low power consumption and low cost. 64 – channel ASIC MAROC from Weeroc provides individual readout of each SiPM and has been considered as the best choice among electronics solutions available on the market. As the photodetector parameters are the key issues here, KETEK SiPMs with high detection efficiency, low crosstalk and low noise have been chosen for this study. In order to study the proposed detection system in detail and obtain detector module parameters, required for MC simulation, a 64-channel small prototype with 6x6mm 2 SiPMs has been constructed and tested. SiPMs in SMD packages have been assembled as a matrix of 8x8 elements and readout by MAROC-based board. Prototype has been tested with different shape NaI(Tl) scintillators and gammas with different energy. Dedicated algorithms for extraction of gamma-event’s energy and position are under development. They are based on fitting a matrix of individual SiPMs responses by an analytical function F(x,y). They will be tested with GEANT-simulated events and experimental data. Development of the next (engineering) prototype of SiPM’s module for gamma-camera will be started soon.

  2. Sensitivity of LDEF foil analyses using ultra-low background germanium vs. large NaI(Tl) multidimensional spectrometers

    International Nuclear Information System (INIS)

    Reeves, J.H.; Arthur, R.J.; Brodzinski, R.L.

    1992-06-01

    Cobalt foils and stainless steel samples were analyzed for induced 6O Co activity with both an ultra-low background germanium gamma-ray spectrometer and with a large NaI(Tl) multidimensional spectrometer, both of which use electronic anticoincidence shielding to reduce background counts resulting from cosmic rays. Aluminum samples were analyzed for 22 Na. The results, in addition to the relative sensitivities and precisions afforded by the two methods, are presented

  3. Theoretical calibration of a NaI(Tl) detector for the measurement of 131I in a thyroid phantom

    International Nuclear Information System (INIS)

    Venturini, Luzia

    2002-01-01

    This paper describes the theoretical calibration of a NaI(Tl) detector using Monte Carlo Method, for the measurement of 131 I in a thyroid phantom. The thyroid is represented by the region between two concentric cylinders, where the inner one represents the trachea and the outer one represents the neck. 133 Ba was used for experimental calibration. The results shows that the calibration procedure is suitable for 131 I measurements. (author)

  4. Comparison of PVT and NaI(Tl) scintillators for vehicle portal monitor applications

    International Nuclear Information System (INIS)

    Siciliano, E.R.; Ely, J.H.; Kouzes, R.T.; Milbrath, B.D.; Schweppe, J.E.; Stromswold, D.C.

    2005-01-01

    The demand for radiation portal monitor (RPM) systems has increased, and their capabilities are being further scrutinized as they are being applied to the task of detecting nuclear weapons, special nuclear material, and radiation dispersal device materials that could appear at borders. The requirements and constraints on RPM systems deployed at high-volume border crossings are significantly different from those at weapons facilities or steel recycling plants, where RPMs have been historically employed. In this new homeland security application, RPM systems must rapidly detect localized sources of radiation with a very high detection probability and low false-alarm rate, while screening all of the traffic without impeding the flow of commerce. In light of this new Department of Homeland Security application, the capabilities of two popular gamma-ray-detector materials as applied to these needs are re-examined. Both experimental data and computer simulations, together with practical deployment experience, are used to assess currently available polyvinyltoluene and NaI(Tl) gamma-ray detectors for border applications

  5. Response of parylene-coated NaI(Tl scintillators at low temperature

    Directory of Open Access Journals (Sweden)

    Coron Noël

    2014-01-01

    Full Text Available Despite that it is widely used as a scintillator at room temperature, the hygroscopicity of NaI complicates its handling and limits its application for many purposes, for example as a cryogenic detector. To overcome this problem we study coating materials that can act as humidity barriers, in particular parylene, a polymer that can be deposited in very radiopure, thin and conformal layers. In this work, several NaI(Tl samples coated with 2-5 µm parylene-C were tested at low temperature. Luminescence spectra under X-ray excitation are presented at several temperatures as well as the light output vs temperature at 1.5-300 K. Several thermoluminescence peaks were observed at around 60, 95 and 150 K during warm up to room temperature. The mechanical resistance of the coating under thermal cycles was also investigated, and we observed a degradation of the optical appearance and the light output after cooling down to about 100 mK, which compromises the reusability of the samples.

  6. Frequency Domain Multiplexing for Use With NaI[Tl] Detectors

    Science.gov (United States)

    Belling, Samuel; Coherent Collaboration

    2017-09-01

    A process used in many forms of signal communication known as multiplexing is adapted for the purpose of combining signals from NaI[Tl] detectors so that fewer digitizer channels can be used to process the signal information from large experiments within the COHERENT collaboration. Each signal is passed through a ringing circuit to modulate it with a characteristic frequency. Information about the signal can be extracted from its amplitude, frequency, and phase. Simulations in LTSpice show that an operational amplifier circuit with a parallel LRC feedback loop can serve as the modulating circuit. Several such circuits can be constructed and housed compactly in a unit, and fed to an inverting, summing amplifier with tunable gain, such that the signals are carried by one cable. The signals are analyzed based on a Fourier transform after being digitized. The results show that the energy, channel, and time of the original interaction can be recovered by this process. In some cases it is possible through filtering and deconvolution to recover the shape of the original signal. The effort is ongoing, but with the design presented it is possible to multiplex 10 detectors into a single digitizer channel. NSF REU Program at Duke University.

  7. Expanding of FOV of NaI(Tl) gamma camera detectors-Is it possible?

    International Nuclear Information System (INIS)

    Gayshan, Vadim L.; Gektin, A.V.; Boyarintsev, A.; Pedash, V.

    2006-01-01

    Every gamma camera detector used for medical imaging of conventional design faces the problem of distorted or no information readout at the areas closer to the edge of detectors. Obtaining position and energy information becomes almost impossible at distance 0-12 of PMT size from the edge. Therefore, in some designs were proposed losing of edge energy resolution while improving in spatial uniformity when it comes to imaging at the edges. This work is dedicated to understanding of the problem, mathematical simulations, practical tests and recommendations to build detectors with larger usable FOV without increasing in dimensions. To study the problem we built the test jig with linear motion source and readout electronics to simulate gamma cameras of PMTs. Based on simulation results the idea of modifying of crystal shape combined with specific light redirection system of baffles was tested and allowed to expand usable FOV. The results are presented and showed that for traditional NaI(Tl) scintillators using 2'' PMT may be possible to obtain relatively good spatial resolution starting from 4-5mm from the edge of a detector. The question of economical efficiency of proposed method is being investigated and a special detector manufacturing technology must be developed to accommodate this. While we believe that achieved results are very important for small size detectors (<20cm) they could be beneficial even for larger detectors used in whole body imaging systems

  8. Performance assessment of a NaI(Tl) gamma counter for PET applications with methods for improved quantitative accuracy and greater standardization

    OpenAIRE

    Lodge, Martin A; Holt, Daniel P; Kinahan, Paul E; Wong, Dean F; Wahl, Richard L

    2015-01-01

    Background Although NaI(Tl) gamma counters play an important role in many quantitative positron emission tomography (PET) protocols, their calibration for positron-emitting samples has not been standardized across imaging sites. In this study, we characterized the operational range of a gamma counter specifically for positron-emitting radionuclides, and we assessed the role of traceable 68Ge/68Ga sources for standardizing system calibration. Methods A NaI(Tl) gamma counter was characterized w...

  9. Development of source-less efficiency calibration procedure for CeBr3 based gamma spectrometry system

    International Nuclear Information System (INIS)

    Verma, Amit K.; Narayani, K.; Pant, Amar D.; Bhosale, Nitin; Anilkumar, S.; Palani Selvam, T.

    2018-01-01

    Scintillation spectrometers are widely used in detection and spectrometry of gamma photons. Sodium Iodide (NaI(Tl)) is the most commonly used scintillation detector for gamma ray spectrometry. However for portable application that require higher efficiency and better resolution Cerium Bromide (CeBr 3 ) crystals are more suitable than NaI(Tl) crystals. CeBr 3 detectors have high light output (∼ 68,000 photons/MeV), good proportionality, fast response and better energy resolution (<4% for 662 keV of 137 Cs), which makes it very promising detector for gamma ray spectrometry. In the present work, experimental and Monte Carlo based efficiencies for CeBr 3 detector for 137 Cs and 60 Co were evaluated

  10. Mobile gamma spectrometry. Evaluation of the Resume 99 exercise

    International Nuclear Information System (INIS)

    Mellander, H.; Karlsson, S.; Aage, H.K.; Korsbech, U.; Lauritzen, B.; Smethurst, M.

    2002-06-01

    During the RESUME 99 exercise, the radiocaesium ( 137 Cs) activity in the surroundings of Gavle in central Sweden was ma p ped using car-borne gamma-ray spectrometry (CGS). The CGS data along with airborne gamma-ray spectrometry (AGS) data from the same area have been used to examine possible correlations between the CGS and AGS results, detector type and position, and geographical information, such as land-use and road type. The overall differences between various CGS results are small, while larger differences are found between AGS and CGS results. In general only little correlation was found with land-use and with road-type and width. The differences between AGS and CGS results arise because airborne detectors have a different field of view than a ground-based detector. From an analysis of the depth-dependency of AGS and CGS data for a depth-distributed source, it is found that the mean mass depth may be inferred from the ratio of AGS to CGS spectral count rates. Integration of AGS and CGS data requires a precise definition of quantities and units for reporting activity concentrations in a complicated geometry and care must be taken to translate AGS results into equivalent CGS quantities taking into account the spatial distribution of the radionuclides. (au)

  11. Mobile gamma spectrometry. Evaluation of the Resume 99 exercise

    Energy Technology Data Exchange (ETDEWEB)

    Mellander, H.; Karlsson, S. [Swedish Radiation Protection Authority, Stockholm (Sweden); Aage, H.K.; Korsbech, U. [Technical Univ. of Denmark, Lyngby (Denmark); Lauritzen, B. [Risoe National Laboratory, Roskilde (Denmark); Smethurst, M. [Geological Survey of Norway, Trondheim (Norway)

    2002-06-01

    During the RESUME 99 exercise, the radiocaesium ({sup 137}Cs) activity in the surroundings of Gavle in central Sweden was ma{sup p}ped using car-borne gamma-ray spectrometry (CGS). The CGS data along with airborne gamma-ray spectrometry (AGS) data from the same area have been used to examine possible correlations between the CGS and AGS results, detector type and position, and geographical information, such as land-use and road type. The overall differences between various CGS results are small, while larger differences are found between AGS and CGS results. In general only little correlation was found with land-use and with road-type and width. The differences between AGS and CGS results arise because airborne detectors have a different field of view than a ground-based detector. From an analysis of the depth-dependency of AGS and CGS data for a depth-distributed source, it is found that the mean mass depth may be inferred from the ratio of AGS to CGS spectral count rates. Integration of AGS and CGS data requires a precise definition of quantities and units for reporting activity concentrations in a complicated geometry and care must be taken to translate AGS results into equivalent CGS quantities taking into account the spatial distribution of the radionuclides. (au)

  12. First search for a dark matter annual modulation signal with NaI(Tl) in the Southern Hemisphere by DM-Ice17

    Energy Technology Data Exchange (ETDEWEB)

    Barbosa de Souza, E.; Cherwinka, J.; Cole, A.; Ezeribe, A. C.; Grant, D.; Halzen, F.; Heeger, K. M.; Hsu, L.; Hubbard, A. J. F.; Jo, J. H.; Karle, A.; Kauer, M.; Kudryavtsev, V. A.; Lim, K. E.; Macdonald, C.; Maruyama, R. H.; Mouton, F.; Paling, S. M.; Pettus, W.; Pierpoint, Z. P.; Reilly, B. N.; Robinson, M.; Rogers, F. R.; Sandstrom, P.; Scarff, A.; Spooner, N. J. C.; Telfer, S.; Yang, L.

    2017-02-28

    The first search for a dark matter annual modulation signal with NaI(Tl) target material in the Southern Hemisphere conducted with the DM-Ice17 experiment is presented. DM-Ice17 consists of 17 kg of NaI(Tl) scintillating crystal under 2200 m.w.e. overburden of Antarctic glacial ice. The analysis presented here utilizes a 60.8 kg yr exposure. While unable to exclude the signal reported by DAMA/LIBRA, the DM-Ice17 data are consistent with no modulation in the energy range of 4-20 keV, providing the strongest limits on WIMP candidates from a direct detection experiment located in the Southern Hemisphere. Additionally, the successful deployment and stable operation of 17 kg of NaI(Tl) crystal over 3.5 years establishes the South Pole ice as a viable location for future underground, low-background experiments.

  13. Photopeak efficiency response function of an underwater gamma-ray NaI(Tl) detector using MCNP-X

    International Nuclear Information System (INIS)

    Salgado, William L.; Silva, Ademir X.; Salgado, Cesar M.

    2015-01-01

    This work presents a study to calculate the response function of a 1.5″ x 1″ NaI(Tl) scintillation detector when it is used in the marine environment in the energy range from 20 keV to 662 keV. The method takes into account both the scattering of photons in the water and the detection mechanism of the detector. In addition, the calculation of the response function of the whole system is essential for suppressing the background of the measurement and for estimating the concentration of the involved radionuclides, especially given the greater probability of primary gamma photons undergoing multiple scattering events before they interact with the detector. The experimental photopeak efficiency measurements for point sources were compared with the simulated results under the same conditions of the experimental setup to validate the simulation of the detector. Monte Carlo simulations were performed using the MCNP-X code for the investigation of gamma-ray absorption in water in different brines. The energy resolution curve was used to improve the response of the mathematical simulation of the detector. The detector’s simulation was based on information obtained from the gammagraphy technique. Both dimensions and materials were used for the calculation with the MCNP-X code. The photopeak efficiency of a NaI(Tl) detector for different radionuclides in the aquatic environment with different salinities was calculated. (author)

  14. Application of the dose conversion factor for a NaI(Tl) detector to the radwaste drum assay

    International Nuclear Information System (INIS)

    Ji, Young-Yong; Hong, Dae-Seok; Kim, Tae-Kuk; Kwak, Kyung-Kil; Ryu, Woo-Seog

    2011-01-01

    The dose-to-curie (DTC) conversion method has been known that there could be extremely high uncertainty associated with establishing the radioactivity of gamma emitters in a drum. However, the DTC conversion method is still an effective assay method to calculate the radioisotope inventory because of the simple and easy procedures to be applied. In order to make the DTC conversion method practical, numerous assumptions and limitations placed on its use. These assumptions and limitations are related to the dose rate measurement and the relative abundance of gamma emitters in a drum. However, these two variables were generally obtained from the different detection mechanisms even using the different radwaste each other. Unfortunately, that expanded the limitation of using the DTC conversion method. In order to obtain two variables in a drum to be assayed at once, the dose conversion factor for a NaI(Tl) detector was first calculated from the MCNP code. The pulse height spectrum from a simulated drum inserted into a standard source was measured by a NaI(Tl) detector, and then, two variables were calculated from the dose conversion factor and the net count rate of detected gamma emitters in the pulse height spectrum.

  15. Comparison of total experimental and theoretical absolute γ-ray detection efficiencies of a cylindrical NaI(Tl) crystal

    International Nuclear Information System (INIS)

    Uosif, M.A.; El-Taher, A.

    2005-01-01

    A new fit function has been developed to calculate theoretically the absolute gamma ray detection efficiencies (ηTh) of a cylindrical NaI(Tl) crystal, for calculating the absolute efficiency at any interesting gamma energy in the energy range between 10 and 1300 keV and distance between 0 and 8 cm. The total absolute gamma ray detection efficiencies have been calculated for five detectors, four are 2x2 and one is 3x 3 inches NaI(Tl) crystal at different distances. The absolute efficiency of the different detectors was calculated at the specific energy of the standard sources for each measuring distances. In this calculation, experimental (ηExp) and theoretical (ηTh) have been calculated. The uncertainties of efficiency calibration have been calculated also for quality control. Measurements were performed with calibrated point source. Gamma-ray energies under consideration were 0.356, 0.662, 1.17 and 1.33 MeV. The differences between (ηExp) and (ηTh) at these energies are 1.30E-06, 7.99E-05, 2.29E-04 and 2.42E-04 respectively. The results obtained on the basis of (ηExp) and (ηTh) seem to be in very good agreement

  16. A study of the effect of Al2O3 reflector on response function of NaI(Tl) detector

    International Nuclear Information System (INIS)

    Tam, Hoang Duc; Chuong, Huynh Dinh; Thanh, Tran Thien; Van Tao, Chau

    2016-01-01

    This study aims to assess the effect of Al 2 O 3 reflector surrounding the NaI(Tl) crystal on the detector response function, based on Monte Carlo simulation, which can verify the precise model of the NaI(Tl) detector. The method used in determining the suitable thickness of Al 2 O 3 reflector is to compare the calculated and experimental values of full-energy peak efficiency. The results show that the Al 2 O 3 reflector should have a thickness of 0.8–1.2 mm for the maximum deviation between the experimental and simulated efficiency of 3.2% at all concerning energies. In addition, the obtained results are in good agreement with the response function of simulation and experimental spectra. - Highlights: • The study was conducted to verify the model of Monte Carlo simulation. • The effect of Al 2 O 3 reflector on the detector response function was investigated. • The optimum thickness of Al 2 O 3 reflector is suggested.

  17. Measurement of radioactive tracer microsphere blood from with NaI(Tl)- and Ge-well type detectors

    International Nuclear Information System (INIS)

    Winkler, B.; Staemmler, G.; Schaper, W.; Frank, J.; Langsdorf, S.

    1982-01-01

    An intrinsic Ge-well type detector was applied for the detection of gamma rays from labeled tracer microspheres. The high energy resolution and the large peak-to-Compton ratio of this spectrometer ensures the application of all available differently labeled tracer microspheres in one experiment. The superior energy resolution of the Ge-detector was documented with the separated photopeak regions of 103-Ru and 85-Sr-labeled tracer microspheres, which result in a single photopeak when an NaI(Tl) detector is used. The Ge-well type detector was compared with an NaI(Tl) spectrometer by counting samples of cardiac muscle in either spectrometer systems. Regression analysis between both spectrometer systems demonstrate identical flow values in these samples for 5 differently labeled tracer microspheres which were administered in 5 dogs. The high sensitivity of the Ge-well-type detector together with a suitable technique for sampling of myocardial tissue accomplishes a high spatial resolution of myocardial perfusion for all available differently labeled tracer microspheres. (orig.)

  18. Use of a low energy proton accelerator for calibrating a large NaI(Tl) array in a high energy physics experiment

    International Nuclear Information System (INIS)

    Kirkbride, G.I.; O'Reilly, J.G.; Tompkins, J.C.

    1978-01-01

    The use of a 500 keV Van de Graaff proton accelerator to produce γ-rays in the range 4 - 18 MeV via nuclear reactions for the purpose of calibrating a large NaI(Tl) crystal array is reported. Data analysis indicates an energy calibration to approx. 1% over this range

  19. Calibration of angle response of a NaI(Tl) airborne spectrometer to 137Cs and 60Co point sources on the ground

    International Nuclear Information System (INIS)

    Liu Xinhua; Zhang Yongxing; Gu Renkang; Shen Ensheng

    1998-01-01

    The angle response function F(φ,θ) is a basic calibration of airborne spectrometers in airborne surveying for nuclear emergency monitoring. The author describes the method and results of angle response function calibration of a NaI(Tl) airborne spectrometer for 137 Cs and 60 Co point sources on the ground, with less than 20% uncertainty. By using the results, the calibration factors of the NaI(Tl) airborne spectrometer fixed in Yun-5 plane at different flying heights are calculated by numerical integral method for 137 Cs uniform area source on ground surface, with less than 25% uncertainty. The minimum detection limits (L D ) are calculated at 90 m and 120 m flying heights in the range of over Shijiazhuang airborne surveying for 137 Cs uniform area source on ground surface to be 3.83 and 5.62 kBq/m 2 , respectively

  20. Investigation and optimisation of mobile NaI(Tl) and 3He-based neutron detectors for finding point sources

    International Nuclear Information System (INIS)

    Nilsson, Jonas M.C.; Finck, Robert R.; Rääf, Christopher

    2015-01-01

    Neutron radiation produces high-energy gamma radiation through (n,γ) reactions in matter. This can be used to detect neutron sources indirectly using gamma spectrometers. The sensitivity of a gamma spectrometer to neutrons can be amplified by surrounding it with polyvinyl chloride (PVC). The hydrogen in the PVC acts as a moderator and the chlorine emits prompt gammas when a neutron is captured. A 4.7-l 3 He-based mobile neutron detector was compared to a 4-l NaI(Tl)-detector covered with PVC using this principle. Methods were also developed to optimise the measurement parameters of the systems. The detector systems were compared with regard to their ability to find 241 AmBe, 252 Cf and 238 Pu– 13 C neutron sources. Results from stationary measurements were used to calculate optimal integration times as well as minimum detectable neutron emission rates. It was found that the 3 He-based detector was more sensitive to 252 Cf sources whereas the NaI(Tl) detector was more sensitive to 241 AmBe and 238 Pu– 13 C sources. The results also indicated that the sensitivity of the detectors to sources at known distances could theoretically be improved by 60% by changing from fixed integration times to list mode in mobile surveys

  1. NaI(Tl) scintillator detectors stripping procedure for air kerma measurements of diagnostic X-ray beams

    Energy Technology Data Exchange (ETDEWEB)

    Oliveira, L.S.R. [Centro Tecnológico do Exército, CTEx (Brazilian Army Technological Center), Av. das Américas n° 28705, 23085-470 Rio de Janeiro (Brazil); Instituto de Radioprotecão e Dosimetria, CNEN/IRD (Institute for Radioprotection and Dosimetry, CNEN/IRD), Av. Salvador Allende s/no, P.O. Box 37750, 22783-127 Barra da Tijuca, Rio de Janeiro (Brazil); Conti, C.C., E-mail: ccconti@ird.gov.br [Instituto de Radioprotecão e Dosimetria, CNEN/IRD (Institute for Radioprotection and Dosimetry, CNEN/IRD), Av. Salvador Allende s/no, P.O. Box 37750, 22783-127 Barra da Tijuca, Rio de Janeiro (Brazil); Amorim, A.S.; Balthar, M.C.V. [Centro Tecnológico do Exército, CTEx (Brazilian Army Technological Center), Av. das Américas n° 28705, 23085-470 Rio de Janeiro (Brazil)

    2013-03-21

    Air kerma is an essential quantity for the calibration of national standards used in diagnostic radiology and the measurement of operating parameters used in radiation protection. Its measurement within the appropriate limits of accuracy, uncertainty and reproducibility is important for the characterization and control of the radiation field for the dosimetry of the patients submitted to diagnostic radiology and, also, for the assessment of the system which produces radiological images. Only the incident beam must be considered for the calculation of the air kerma. Therefore, for energy spectrum, counts apart the total energy deposition in the detector must be subtracted. It is necessary to establish a procedure to sort out the different contributions to the original spectrum and remove the counts representing scattered photons in the detector’s materials, partial energy deposition due to the interactions in the detector active volume and, also, the escape peaks contributions. The main goal of this work is to present spectrum stripping procedure, using the MCNP Monte Carlo computer code, for NaI(Tl) scintillation detectors to calculate the air kerma due to an X-ray beam usually used in medical radiology. The comparison between the spectrum before stripping procedure against the reference value showed a discrepancy of more than 63%, while the comparison with the same spectrum after the stripping procedure showed a discrepancy of less than 0.2%.

  2. NaI(Tl) scintillator detectors stripping procedure for air kerma measurements of diagnostic X-ray beams

    Science.gov (United States)

    Oliveira, L. S. R.; Conti, C. C.; Amorim, A. S.; Balthar, M. C. V.

    2013-03-01

    Air kerma is an essential quantity for the calibration of national standards used in diagnostic radiology and the measurement of operating parameters used in radiation protection. Its measurement within the appropriate limits of accuracy, uncertainty and reproducibility is important for the characterization and control of the radiation field for the dosimetry of the patients submitted to diagnostic radiology and, also, for the assessment of the system which produces radiological images. Only the incident beam must be considered for the calculation of the air kerma. Therefore, for energy spectrum, counts apart the total energy deposition in the detector must be subtracted. It is necessary to establish a procedure to sort out the different contributions to the original spectrum and remove the counts representing scattered photons in the detector's materials, partial energy deposition due to the interactions in the detector active volume and, also, the escape peaks contributions. The main goal of this work is to present spectrum stripping procedure, using the MCNP Monte Carlo computer code, for NaI(Tl) scintillation detectors to calculate the air kerma due to an X-ray beam usually used in medical radiology. The comparison between the spectrum before stripping procedure against the reference value showed a discrepancy of more than 63%, while the comparison with the same spectrum after the stripping procedure showed a discrepancy of less than 0.2%.

  3. Experimental response function of NaI(Tl) scintillation detector for gamma photons and tomographic measurements for defect detection

    International Nuclear Information System (INIS)

    Sharma, Amandeep; Singh, Karamjit; Singh, Bhajan; Sandhu, B.S.

    2011-01-01

    The response function of gamma detector is an important factor for spectrum analysis because some photons and secondary electrons may escape the detector volume before fully depositing their energy, of course destroys the ideal delta function response. An inverse matrix approach, for unfolding of observed pulse-height distribution to a true photon spectrum, is used for construction of experimental response function by formulating a 40 x 40 matrix with bin mesh (E 1/2 ) of 0.025 (MeV) 1/2 for the present measurements. A tomographic scanner system, operating in a non-destructive and non-invasive way, is also presented for inspection of density variation in any object. The incoherent scattered intensity of 662 keV gamma photons, obtained by unfolding (deconvolution) the experimental pulse-height distribution of NaI(Tl) scintillation detector, provides the desired information. The method is quite sensitive, for showing inclusion of medium Z (atomic number) material (iron) in low Z material (aluminium) and detecting a void of ∼2 mm in size for iron block, to investigate the inhomogeneities in the object. Also, the grey scale images (using 'MATLAB') are shown to visualise the presence of defects/inclusion in metal samples.

  4. Comparison of multi-pole shaping and delay line clipping pre-amplifiers for position sensitive NaI(Tl) detectors

    International Nuclear Information System (INIS)

    Freifelder, R.; Karp, J.S.; Wear, J.A.; Lockyer, N.S.; Newcomer, F.M.; Surti, S.; Berg, R. van

    1998-01-01

    NaI(Tl) position sensitive detectors have been used in medical imaging for many years. For PET applications without collimators, the high counting rates place severe demands on such large area detectors. The NaI(Tl) detectors in the PENN-PET scanners are read-out via photomultiplier tubes and preamplifiers. Those preamplifiers use a delay-line clipping technique to shorten the characteristic 240 ns fall time of the NaI(Tl) signal. As an alternative, the authors have investigated a pole-zero network to shorten the signal followed by a multi-pole shaper to produce a symmetric signal suitable for high counting rates. This has been compared to the current design by measuring the energy and spatial resolution of a single detector as a function of different preamplifier designs. Data were taken over a range of ADC integration times and countrates. The new design shows improved energy resolution with short integration times. Effects on spatial resolution and deadtime are reported for large position sensitive detectors at different countrates

  5. Urban gamma spectrometry. Report 1

    International Nuclear Information System (INIS)

    Aage, H.K.; Kuukankorpi, S.; Moring, M.; Smolander, P.; Toivonen, H.

    2009-06-01

    This report contains the present status and results for the NKS UGS-project per 1 June 2006 for NKS partners DTU, Denmark, and STUK, Finland. The Danish and Finnish CGS (Carborne Gamma Spectrometry) systems are not of similar types. The Danish CGS system(s) only make use of one NaI(Tl) detector whereas the Finnish CGS system consists of several detectors, NaI(Tl) and HPGe both and as an additional feature the Finnish detectors have position dependent different fields of view. Furthermore, the Finnish system is equipped with an air sampling system. In terms of operation, the Danish detector is located on the rooftop where as the Finnish detectors are located inside the vehicle. The Finnish and the Danish team use different methods for data processing. STUK uses a hypothesis test method to get robust real time alarms (within 10 seconds) when significant peaks from a previously defined set of nuclides are detected. An alarm for a significantly elevated total pulse rate is sent if none of the predefined nuclides is identified. All data are stored to the LINSSI database, which facilitates easy data retrieval for post processing. DEMA/DTU bases their calculations on full spectrum fitting using NASVD and the Danish software NucSpec. Source signals are found from spectrum fitting residuals or from stripping of energy windows - either by the standard 4-windows method or by a measurement based method where stripping factors for any window of interest can be derived from the measurements themselves. A thorough description of the two systems and data processing methods (including mathematics) are described in this report. For the Danish methods of data processing some comparisons have been made, but no final conclusion has been reached yet. Raw urban data has been investigated along with urban data sets to which source signals have been added and searched for. For the Finnish method calibration plots of the minimum detection limits for two different detector types have been

  6. Urban gamma spectrometry. Report 1

    Energy Technology Data Exchange (ETDEWEB)

    Aage, H K [Technical Univ. of Denmark, Kgs. Lyngby (Denmark); Kuukankorpi, S; Moring, M; Smolander, P; Toivonen, H [Radiation and Nuclear Safety Authority, Helsinki (Finland)

    2009-06-15

    This report contains the present status and results for the NKS UGS-project per 1 June 2006 for NKS partners DTU, Denmark, and STUK, Finland. The Danish and Finnish CGS (Carborne Gamma Spectrometry) systems are not of similar types. The Danish CGS system(s) only make use of one NaI(Tl) detector whereas the Finnish CGS system consists of several detectors, NaI(Tl) and HPGe both and as an additional feature the Finnish detectors have position dependent different fields of view. Furthermore, the Finnish system is equipped with an air sampling system. In terms of operation, the Danish detector is located on the rooftop where as the Finnish detectors are located inside the vehicle. The Finnish and the Danish team use different methods for data processing. STUK uses a hypothesis test method to get robust real time alarms (within 10 seconds) when significant peaks from a previously defined set of nuclides are detected. An alarm for a significantly elevated total pulse rate is sent if none of the predefined nuclides is identified. All data are stored to the LINSSI database, which facilitates easy data retrieval for post processing. DEMA/DTU bases their calculations on full spectrum fitting using NASVD and the Danish software NucSpec. Source signals are found from spectrum fitting residuals or from stripping of energy windows - either by the standard 4-windows method or by a measurement based method where stripping factors for any window of interest can be derived from the measurements themselves. A thorough description of the two systems and data processing methods (including mathematics) are described in this report. For the Danish methods of data processing some comparisons have been made, but no final conclusion has been reached yet. Raw urban data has been investigated along with urban data sets to which source signals have been added and searched for. For the Finnish method calibration plots of the minimum detection limits for two different detector types have been

  7. (99m)Tc-MDP bone scintigraphy of the hand: comparing the use of novel cadmium zinc telluride (CZT) and routine NaI(Tl) detectors.

    Science.gov (United States)

    Koulikov, Victoria; Lerman, Hedva; Kesler, Mikhail; Even-Sapir, Einat

    2015-12-01

    Cadmium zinc telluride (CZT) solid-state detectors have been recently introduced in the field of nuclear medicine in cardiology and breast imaging. The aim of the current study was to evaluate the performance of the novel detectors (CZT) compared to that of the routine NaI(Tl) in bone scintigraphy. A dual-headed CZT-based camera dedicated originally to breast imaging has been used, and in view of the limited size of the detectors, the hands were chosen as the organ for assessment. This is a clinical study. Fifty-eight consecutive patients (total 116 hands) referred for bone scan for suspected hand pathology gave their informed consent to have two acquisitions, using the routine camera and the CZT-based camera. The latter was divided into full-dose full-acquisition time (FD CZT) and reduced-dose short-acquisition time (RD CZT) on CZT technology, so three image sets were available for analysis. Data analysis included comparing the detection of hot lesions and identification of the metacarpophalangeal, proximal interphalangeal, and distal interphalangeal joints. A total of 69 hot lesions were detected on the CZT image sets; of these, 61 were identified as focal sites of uptake on NaI(Tl) data. On FD CZT data, 385 joints were identified compared to 168 on NaI(Tl) data (p < 0.001). There was no statistically significant difference in delineation of joints between FD and RD CZT data as the latter identified 383 joints. Bone scintigraphy using a CZT-based gamma camera is associated with improved lesion detection and anatomic definition. The superior physical characteristics of this technique raised a potential reduction in administered dose and/or acquisition time without compromising image quality.

  8. Collisions of neutrons and of gamma rays in Bi4Ge3O12 (BGO) and NaI(Tl) scintillation detectors

    International Nuclear Information System (INIS)

    Kushneriuk, S.A.; Lone, M.A.; Hausser, O.; Wong, P.Y.

    1983-06-01

    The role of collision/escape probabilities in establishing the prompt response of bismuth germanate and NaI(Tl) scintillators is investigated. A possible approximation to the collision probability is discussed. Exact expressions for the probability of escape of radiation from finite, right circular cylindrical and rectangular parallelepiped-shaped detectors are derived from an exponential-like spatial distribution of the source in the detector medium and a parametrized angular distribution of emission of the source. Fairly extensive tables of collision probabilities calculated for these bodies are given. For purposes of comparison some results obtained previously in a Monte Carlo calculation are also presented and discussed

  9. Theoretical calibration of a NaI(Tl) detector for the measurement of {sup 131}I in a thyroid phantom; Calibracao teorica de um detetor NaI(Tl) para a determinacao de {sup 131}I em um simulador de tireoide

    Energy Technology Data Exchange (ETDEWEB)

    Venturini, Luzia [Instituto de Pesquisas Energeticas e Nucleares (IPEN), Sao Paulo, SP (Brazil). Dept. de Metrologia das Radiacoes]. E-mail: lventur@net.ipen.br

    2002-07-01

    This paper describes the theoretical calibration of a NaI(Tl) detector using Monte Carlo Method, for the measurement of {sup 131} I in a thyroid phantom. The thyroid is represented by the region between two concentric cylinders, where the inner one represents the trachea and the outer one represents the neck. {sup 133} Ba was used for experimental calibration. The results shows that the calibration procedure is suitable for {sup 131} I measurements. (author)

  10. A new NaI(Tl) four-detector layout for field contamination assessment using artificial neural networks and the Monte Carlo method for system calibration

    International Nuclear Information System (INIS)

    Moreira, M.C.F.; Conti, C.C.; Schirru, R.

    2010-01-01

    An NaI(Tl) multidetector layout combined with the use of Monte Carlo (MC) calculations and artificial neural networks(ANN) is proposed to assess the radioactive contamination of urban and semi-urban environment surfaces. A very simple urban environment like a model street composed of a wall on either side and the ground surface was the study case. A layout of four NaI(Tl) detectors was used, and the data corresponding to the response of the detectors were obtained by the Monte Carlo method. Two additional data sets with random values for the contamination and for detectors' response were also produced to test the ANNs. For this work, 18 feedforward topologies with backpropagation learning algorithm ANNs were chosen and trained. The results showed that some trained ANNs were able to accurately predict the contamination on the three urban surfaces when submitted to values within the training range. Other results showed that generalization outside the training range of values could not be achieved. The use of Monte Carlo calculations in combination with ANNs has been proven to be a powerful tool to perform detection calibration for highly complicated detection geometries.

  11. A new NaI(Tl) four-detector layout for field contamination assessment using artificial neural networks and the Monte Carlo method for system calibration

    Energy Technology Data Exchange (ETDEWEB)

    Moreira, M.C.F., E-mail: marcos@ird.gov.b [Universidade Federal do Rio de Janeiro, COPPE, Programa de Engenharia Nuclear, Laboratorio de Monitoracao de Processos (Federal University of Rio de Janeiro, COPPE, Nuclear Engineering Program, Process Monitoring Laboratory), P.O. Box 68509, 21941-972 Rio de Janeiro (Brazil); Instituto de Radioprotecao e Dosimetria, CNEN/IRD (Radiation Protection and Dosimetry Institute, CNEN/IRD), Av. Salvador Allende s/no, P.O. Box 37750, 22780-160 Rio de Janeiro (Brazil); Conti, C.C. [Instituto de Radioprotecao e Dosimetria, CNEN/IRD (Radiation Protection and Dosimetry Institute, CNEN/IRD), Av. Salvador Allende s/no, P.O. Box 37750, 22780-160 Rio de Janeiro (Brazil); Schirru, R. [Universidade Federal do Rio de Janeiro, COPPE, Programa de Engenharia Nuclear, Laboratorio de Monitoracao de Processos (Federal University of Rio de Janeiro, COPPE, Nuclear Engineering Program, Process Monitoring Laboratory), P.O. Box 68509, 21941-972 Rio de Janeiro (Brazil)

    2010-09-21

    An NaI(Tl) multidetector layout combined with the use of Monte Carlo (MC) calculations and artificial neural networks(ANN) is proposed to assess the radioactive contamination of urban and semi-urban environment surfaces. A very simple urban environment like a model street composed of a wall on either side and the ground surface was the study case. A layout of four NaI(Tl) detectors was used, and the data corresponding to the response of the detectors were obtained by the Monte Carlo method. Two additional data sets with random values for the contamination and for detectors' response were also produced to test the ANNs. For this work, 18 feedforward topologies with backpropagation learning algorithm ANNs were chosen and trained. The results showed that some trained ANNs were able to accurately predict the contamination on the three urban surfaces when submitted to values within the training range. Other results showed that generalization outside the training range of values could not be achieved. The use of Monte Carlo calculations in combination with ANNs has been proven to be a powerful tool to perform detection calibration for highly complicated detection geometries.

  12. A New Approach for the Determination of Dose Rate and Radioactivity for Detected Gamma Nuclides Using an Environmental Radiation Monitor Based on an NaI(Tl) Detector.

    Science.gov (United States)

    Ji, Young-Yong; Kim, Chang-Jong; Lim, Kyo-Sun; Lee, Wanno; Chang, Hyon-Sock; Chung, Kun Ho

    2017-10-01

    To expand the application of dose rate spectroscopy to the environment, the method using an environmental radiation monitor (ERM) based on a 3' × 3' NaI(Tl) detector was used to perform real-time monitoring of the dose rate and radioactivity for detected gamma nuclides in the ground around an ERM. Full-energy absorption peaks in the energy spectrum for dose rate were first identified to calculate the individual dose rates of Bi, Ac, Tl, and K distributed in the ground through interference correction because of the finite energy resolution of the NaI(Tl) detector used in an ERM. The radioactivity of the four natural radionuclides was then calculated from the in situ calibration factor-that is, the dose rate per unit curie-of the used ERM for the geometry of the ground in infinite half-space, which was theoretically estimated by Monte Carlo simulation. By an intercomparison using a portable HPGe and samples taken from the ground around an ERM, this method to calculate the dose rate and radioactivity of four nuclides using an ERM was experimentally verified and finally applied to remotely monitor them in real-time in the area in which the ERM had been installed.

  13. Efficiency calibration and coincidence summing correction for large arrays of NaI(Tl) detectors in soccer-ball and castle geometries

    International Nuclear Information System (INIS)

    Anil Kumar, G.; Mazumdar, I.; Gothe, D.A.

    2009-01-01

    Efficiency calibration and coincidence summing correction have been performed for two large arrays of NaI(Tl) detectors in two different configurations. They are, a compact array of 32 conical detectors of pentagonal and hexagonal shapes in soccer-ball geometry and an array of 14 straight hexagonal NaI(Tl) detectors in castle geometry. Both of these arrays provide a large solid angle of detection, leading to considerable coincidence summing of gamma rays. The present work aims to understand the effect of coincidence summing of gamma rays while determining the energy dependence of efficiencies of these two arrays. We have carried out extensive GEANT4 simulations with radio-nuclides that decay with a two-step cascade, considering both arrays in their realistic geometries. The absolute efficiencies have been simulated for gamma energies from 700 to 2800 keV using four different double-photon emitters, namely, 60 Co, 46 Sc, 94 Nb and 24 Na. The efficiencies so obtained have been corrected for coincidence summing using the method proposed by Vidmar et al. . The simulations have also been carried out for the same energies assuming mono-energetic point sources, for comparison. Experimental measurements have also been carried out using calibrated point sources of 137 Cs and 60 Co. The simulated and the experimental results are found to be in good agreement. This demonstrates the reliability of the correction method for efficiency calibration of two large arrays in very different configurations.

  14. Efficiency calibration and coincidence summing correction for large arrays of NaI(Tl) detectors in soccer-ball and castle geometries

    Energy Technology Data Exchange (ETDEWEB)

    Anil Kumar, G., E-mail: anilg@tifr.res.i [Department of Nuclear and Atomic Physics, Tata Institute of Fundamental Research, Homi Bhabha Road, Colaba, Mumbai 400005 (India); Mazumdar, I.; Gothe, D.A. [Department of Nuclear and Atomic Physics, Tata Institute of Fundamental Research, Homi Bhabha Road, Colaba, Mumbai 400005 (India)

    2009-11-21

    Efficiency calibration and coincidence summing correction have been performed for two large arrays of NaI(Tl) detectors in two different configurations. They are, a compact array of 32 conical detectors of pentagonal and hexagonal shapes in soccer-ball geometry and an array of 14 straight hexagonal NaI(Tl) detectors in castle geometry. Both of these arrays provide a large solid angle of detection, leading to considerable coincidence summing of gamma rays. The present work aims to understand the effect of coincidence summing of gamma rays while determining the energy dependence of efficiencies of these two arrays. We have carried out extensive GEANT4 simulations with radio-nuclides that decay with a two-step cascade, considering both arrays in their realistic geometries. The absolute efficiencies have been simulated for gamma energies from 700 to 2800 keV using four different double-photon emitters, namely, {sup 60}Co, {sup 46}Sc, {sup 94}Nb and {sup 24}Na. The efficiencies so obtained have been corrected for coincidence summing using the method proposed by Vidmar et al. . The simulations have also been carried out for the same energies assuming mono-energetic point sources, for comparison. Experimental measurements have also been carried out using calibrated point sources of {sup 137}Cs and {sup 60}Co. The simulated and the experimental results are found to be in good agreement. This demonstrates the reliability of the correction method for efficiency calibration of two large arrays in very different configurations.

  15. Ground level cosmic ray pulse height spectrum of a 7. 5 cm diameter spherical NaI(Tl) scintillation detector for energy region below 5 MeV

    Energy Technology Data Exchange (ETDEWEB)

    Nagaoka, Toshi; Saito, Kimiaki; Moriuchi, Shigeru

    1988-09-01

    Ground level cosmic ray pulse height spectrum of a 7.5 cm diameter spherical NaI(Tl) scintillation detector was evaluated through stripping operation based on a pulse height spectrum measured on the sea and high precision response functions of the detector for U-series, Th-series and /sup 40/K. The exposure rate calculated from the determined cosmic ray pulse height spectrum was 0.21 R/h eq., which agreed well with that obtained from another method. The shape of the pulse height spectrum showed similarity to that measured at the altitude of 16,000 ft, especially in the energy region of 0 to 3 MeV. The principle of the adopted method is rather plain, however, the reliability of the spectrum is satisfactory. As the pulse height spectrum is a common information to any analytical method for environmental gamma ray using NaI(Tl) scintillation detector, it is expected to be used for simple and precise separation of cosmic ray component involved in the enviromental pulse height spectrum.

  16. Understanding internal backgrounds in NaI(Tl) crystals toward a 200 kg array for the KIMS-NaI experiment

    Energy Technology Data Exchange (ETDEWEB)

    Adhikari, P.; Adhikari, G.; Oh, S.Y. [Sejong University, Department of Physics, Seoul (Korea, Republic of); Choi, S.; Joo, H.W.; Kim, K.W.; Kim, S.K. [Seoul National University, Department of Physics and Astronomy, Seoul (Korea, Republic of); Ha, C.; Jeon, E.J.; Kang, W.G.; Kim, H.O.; Kim, N.Y.; Lee, H.S.; Lee, J.H.; Lee, M.H.; Leonard, D.S.; Li, J.; Olsen, S.L.; Park, H.K.; Park, K.S.; So, J.H.; Yoon, Y.S. [Institute for Basic Science, Center for Underground Physics, Daejeon (Korea, Republic of); Hahn, I.S. [Ewha Womans University, Department of Science Education, Seoul (Korea, Republic of); Kim, H.J. [Kyungpook National University, Department of Physics, Daegu (Korea, Republic of); Kim, Y.D. [Sejong University, Department of Physics, Seoul (Korea, Republic of); Institute for Basic Science, Center for Underground Physics, Daejeon (Korea, Republic of); Kim, Y.H. [Institute for Basic Science, Center for Underground Physics, Daejeon (Korea, Republic of); Korea Research Institute of Standards and Science, Daejeon (Korea, Republic of); Park, H.S. [Korea Research Institute of Standards and Science, Daejeon (Korea, Republic of)

    2016-04-15

    The Korea Invisible Mass Search (KIMS) collaboration has developed low-background NaI(Tl) crystals that are suitable for the direct detection of WIMP dark matter. Building on experience accumulated during the KIMS-CsI programs, the KIMS-NaI experiment will consist of a 200 kg NaI(Tl) crystal array surrounded by layers of shielding structures and will be operated at the Yangyang underground laboratory. The goal is to provide an unambiguous test of the DAMA/LIBRA annual modulation signature. Measurements of six prototype crystals show progress in the reduction of internal contamination from radioisotopes. Based on our understanding of these measurements, we expect to achieve a background level in the final detector configuration that is less than 1 count/day/keV/kg for recoil energies around 2 keV. The annual modulation sensitivity for the KIMS-NaI experiment shows that an unambiguous 7σ test of the DAMA/LIBRA signature would be possible with a 600 kg year exposure with this system. (orig.)

  17. Characterization of radioactive orphan sources by gamma spectrometry

    International Nuclear Information System (INIS)

    Cruz W, H.

    2013-01-01

    The sealed radioactive sources are widely applicable in industry. They must have a permanent control and must be registered with the Technical Office of the National Authority (OTAN). However, at times it has identified the presence of abandoned sealed sources unknown to the owner. These sources are called 'orphan sources'. Of course these sources represent a high potential risk because accidents can trigger dire consequences depending on your activity and chemical form in which it presents the radioisotope. This paper describes the process and the actions taken to characterize two orphan radioactive sources from the smelter a Aceros Arequipa. For characterization we used a gamma spectrometry system using a detector NaI(Tl) 3″ x 3″ with a multichannel analyzer Nucleus PCA-II. The radioisotope identified was cesium - 137 ( 137 Cs) in both cases. Fortunately, the sources maintained their integrity would otherwise have generated significant pollution considering the chemical form of the radioisotope and easy dispersion. (author)

  18. Mass spectrometry

    DEFF Research Database (Denmark)

    Nyvang Hartmeyer, Gitte; Jensen, Anne Kvistholm; Böcher, Sidsel

    2010-01-01

    Matrix-assisted laser desorption ionization time-of-flight mass spectrometry (MALDI-TOF MS) is currently being introduced for the rapid and accurate identification of bacteria. We describe 2 MALDI-TOF MS identification cases - 1 directly on spinal fluid and 1 on grown bacteria. Rapidly obtained...

  19. Design and performance of modularized NaI(Tl) detectors with rectangular crystal elements: An array of 49 and the Crystal Box

    International Nuclear Information System (INIS)

    Wilson, S.L.; Hofstadter, R.; Hughes, E.B.; Lin, Y.C.; Parks, R.; Rolfe, J.; Bolton, R.D.; Bowman, J.D.; Cooper, M.D.; Hoffman, C.M.; Hogan, G.E.; Mariam, F.G.; Mischke, R.E.; Nagle, D.E.; Piilonen, L.E.; Sandberg, V.D.; Sanders, G.H.; Werbeck, R.; Williams, R.A.; Frank, J.S.; Hallin, A.L.; Matis, H.S.; Sennhauser, U.; Wright, S.C.

    1988-01-01

    An array of 49 NaI(Tl) modules each 20 inch in depth and 2.5 inch x 2.5 inch in cross section has been constructed and its properties, especially energy resolution, explored for positrons in the range 20 MeV - 18 GeV. A subsequent much larger detector, the Crystal Box, has also been constructed from 396 modules of the same cross section, but mostly 12 inch in depth, and operated as a γ-ray and positron detector in a search for rare muon decays. The calibration procedure used for the Crystal Box and its characteristic resolutions in energy, impact point and time are described. (orig.)

  20. Calculation of total counting efficiency of a NaI(Tl) detector by hybrid Monte-Carlo method for point and disk sources

    Energy Technology Data Exchange (ETDEWEB)

    Yalcin, S. [Education Faculty, Kastamonu University, 37200 Kastamonu (Turkey)], E-mail: yalcin@gazi.edu.tr; Gurler, O.; Kaynak, G. [Department of Physics, Faculty of Arts and Sciences, Uludag University, Gorukle Campus, 16059 Bursa (Turkey); Gundogdu, O. [Department of Physics, School of Engineering and Physical Sciences, University of Surrey, Guildford GU2 7XH (United Kingdom)

    2007-10-15

    This paper presents results on the total gamma counting efficiency of a NaI(Tl) detector from point and disk sources. The directions of photons emitted from the source were determined by Monte-Carlo techniques and the photon path lengths in the detector were determined by analytic equations depending on photon directions. This is called the hybrid Monte-Carlo method where analytical expressions are incorporated into the Monte-Carlo simulations. A major advantage of this technique is the short computation time compared to other techniques on similar computational platforms. Another advantage is the flexibility for inputting detector-related parameters (such as source-detector distance, detector radius, source radius, detector linear attenuation coefficient) into the algorithm developed, thus making it an easy and flexible method to apply to other detector systems and configurations. The results of the total counting efficiency model put forward for point and disc sources were compared with the previous work reported in the literature.

  1. Calculation of total counting efficiency of a NaI(Tl) detector by hybrid Monte-Carlo method for point and disk sources

    International Nuclear Information System (INIS)

    Yalcin, S.; Gurler, O.; Kaynak, G.; Gundogdu, O.

    2007-01-01

    This paper presents results on the total gamma counting efficiency of a NaI(Tl) detector from point and disk sources. The directions of photons emitted from the source were determined by Monte-Carlo techniques and the photon path lengths in the detector were determined by analytic equations depending on photon directions. This is called the hybrid Monte-Carlo method where analytical expressions are incorporated into the Monte-Carlo simulations. A major advantage of this technique is the short computation time compared to other techniques on similar computational platforms. Another advantage is the flexibility for inputting detector-related parameters (such as source-detector distance, detector radius, source radius, detector linear attenuation coefficient) into the algorithm developed, thus making it an easy and flexible method to apply to other detector systems and configurations. The results of the total counting efficiency model put forward for point and disc sources were compared with the previous work reported in the literature

  2. Evaluation of the angular response of LaBr{sub 3}(Ce) and NaI(Tl) radiological identifiers for emergency situations attendance

    Energy Technology Data Exchange (ETDEWEB)

    Izidório, Ana C.A.C.; Cardoso, Domingos D’O.; Oliveira, Luciano S.R.; Balthar, Mario C.V.; Amorim, Aneuri S. de; Santos, Avelino dos; Guimarães Junior, Walter J.; Arbach, Mayara N., E-mail: carolizidorio@hotmail.com, E-mail: domingos.oliveiralvr71@gmail.com, E-mail: walter_guimaraes@ime.eb.br, E-mail: lucianosantarita@gmail.com, E-mail: mariobalthar@gmail.com, E-mail: aneurideamorim@gmail.com, E-mail: hiperav@gmail.com, E-mail: mayaraarbach@gmail.com [Instituto Militar de Engenharia (IME), Rio de Janeiro, RJ (Brazil); Instituto de Defesa Química, Biológica, Radiológica e Nuclear (IDQBRN/CTEx), Barra de Guaratiba, RJ (Brazil); Instituto de Radioprotecao e Dosimetria (IRD/CNEN-RJ), Rio de Janeiro, RJ (Brazil)

    2017-11-01

    The Institute of Chemical, Biological, Radiological and Nuclear Defense (IDQBRN) of the Brazilian Army has been developing activities aimed at characterizing radiological detectors for use during emergency situations and radiological incidents and also for research and academic activities. This work describes the experiments performed in order to evaluate the angular response of LaBr{sub 3}(Ce) and NaI(Tl) portable radiological identifiers (PRI) with scintillator crystal detectors measuring 1.5” x 1.5” and 3.0” x 1.5”, respectively. A {sup 137}Cs source with corrected activity of 2.623 GBq (July 29, 2017) supplied the beam for the experiments. It was positioned at a distance of 1.00 m from the PRIs, together with attenuators, in order to yield different ambient dose equivalent rate, H⁎(10), thus allowing the adjustment of the counting statistics and the analysis of the responses obtained. The objective of this work was to evaluate the angular dependence of the response of LaBr{sub 3}(Ce) and NaI(Tl) PRIs exposed to a {sup 137}Cs source by azimuthally varying the angle of incidence of the primary beam within the 0° ± 30° range, measured from the center of the sensitive volume of the scintillators. The PRIs were programmed to reach a maximum count of 10{sup 6} in order to ensure that the relative uncertainty of the measured data would be negligible which led to improved angular response data, in addition to higher correlation factors and greater reliability in the responses obtained with LaBr{sub 3}(Ce) and NaI(T1) portable radiological identifiers. (author)

  3. Beta spectrometry

    International Nuclear Information System (INIS)

    Dryak, P.; Zderadicka, J.; Plch, J.; Kokta, L.; Novotna, P.

    1977-01-01

    For the purpose of beta spectrometry, a semiconductor spectrometer with one Si(Li) detector cooled with liquid nitrogen was designed. Geometrical detection efficiency is about 10% 4 sr. The achieved resolution for 624 keV conversion electrons of sup(137m)Ba is 2.6 keV (FWHM). A program was written in the FORTRAN language for the correction of the deformation of the measured spectra by backscattering in the analysis of continuous beta spectra. The method permits the determination of the maximum energy of the beta spectrum with an accuracy of +-5 keV. (author)

  4. Recommendations for the measurement 131I in human thyroid using a detector of NaI(Tl)

    International Nuclear Information System (INIS)

    Puerta Yepes, N.; Rojo, A.M.; Andres, P.A.

    2010-01-01

    The Argentine Total Body Counter Laboratory of the Nuclear Regulatory Authority participated in the last regional intercomparison Exercise organized in the frame of the IAEA Project RLA 9/066 related with in vivo measurements of 131 I in the thyroid. There were identified some difficulties in determining the efficiency and calibration factor (CF) for the 131 I when a source of 133 Ba and a detector of NaI (Tl) are used in the calibration process. Independent measurements were performed for two calibration sources of known activity ( 133 Ba and 131 I) with identical geometry pattern and using a gamma spectrometry system with NaI(Ti) detector. It was found that the region of interest (ROI) which, both in the spectrum of 133 Ba as in the spectrum of 131 I, had the same efficiency. It was determined the activity of the source of 133 Ba , distributed in the intercomparison, and the calibrated source of 131 I using different values of efficiency and FC obtained. It was analyzed the conditions under which the use of 133 Ba as a source of calibration is effective for the measurement of 131 I. (authors) [es

  5. Measurements of uranium enrichment by four techniques of gamma-ray spectrometry

    International Nuclear Information System (INIS)

    Tojo, Takao

    1983-12-01

    Measurements of uranium enrichment with the uses of the LMRI (France) UO 2 standards have been made by four techniques of gamma-ray spectrometry, in order to examine measurement characteristics of each technique. The following results were obtained by the three techniques based on the direct determination of the peak area of the 186-keV gamma-rays from 235 U, when the standard sample of 6.297 a/o was used for measuring enrichments ranging from 1.4 a/o to 9.6 a/o ; (i) In a LEPS HP Ge gamma-ray spectrometry, standard deviation of the measured enrichments from the certified ones was 1.4 %, (ii) in a Ge(Li) gamma-ray spectrometry, the standard deviation was 2.0 %, (iii) in a NaI(Tl) gamma-ray spectrometry, the standard deviation was 1.2 %. In the fourth technique, the method of multiple single-channel analyzers, enrichments of 1.4 - 9.6 a/o were measured in the standard deviation of 0.51 %, when the most suitable pairs of standard samples were used for each sample. A part of sources of systematic errors which were caused by each technique adopted was revealed throughout the measurements. And also, it was recognized that the LMRI's values of enrichment were certified precisely, and the UO 2 standards were very useful for enrichment measurements in the four techniques of gamma-ray spectrometry used here. (author)

  6. MCNP-X Monte Carlo Code Application for Mass Attenuation Coefficients of Concrete at Different Energies by Modeling 3 × 3 Inch NaI(Tl Detector and Comparison with XCOM and Monte Carlo Data

    Directory of Open Access Journals (Sweden)

    Huseyin Ozan Tekin

    2016-01-01

    Full Text Available Gamma-ray measurements in various research fields require efficient detectors. One of these research fields is mass attenuation coefficients of different materials. Apart from experimental studies, the Monte Carlo (MC method has become one of the most popular tools in detector studies. An NaI(Tl detector has been modeled, and, for a validation study of the modeled NaI(Tl detector, the absolute efficiency of 3 × 3 inch cylindrical NaI(Tl detector has been calculated by using the general purpose Monte Carlo code MCNP-X (version 2.4.0 and compared with previous studies in literature in the range of 661–2620 keV. In the present work, the applicability of MCNP-X Monte Carlo code for mass attenuation of concrete sample material as building material at photon energies 59.5 keV, 80 keV, 356 keV, 661.6 keV, 1173.2 keV, and 1332.5 keV has been tested by using validated NaI(Tl detector. The mass attenuation coefficients of concrete sample have been calculated. The calculated results agreed well with experimental and some other theoretical results. The results specify that this process can be followed to determine the data on the attenuation of gamma-rays with other required energies in other materials or in new complex materials. It can be concluded that data from Monte Carlo is a strong tool not only for efficiency studies but also for mass attenuation coefficients calculations.

  7. Calibration of a single hexagonal NaI(Tl) detector using a new numerical method based on the efficiency transfer method

    Energy Technology Data Exchange (ETDEWEB)

    Abbas, Mahmoud I., E-mail: mabbas@physicist.net [Physics Department, Faculty of Science, Alexandria University, 21511 Alexandria (Egypt); Badawi, M.S. [Physics Department, Faculty of Science, Alexandria University, 21511 Alexandria (Egypt); Ruskov, I.N. [Frank Laboratory of Neutron Physics, Joint Institute for Nuclear Research, 141980 Dubna (Russian Federation); Institute for Nuclear Research and Nuclear Energy, Bulgarian Academy of Sciences, 1784 Sofia (Bulgaria); El-Khatib, A.M. [Physics Department, Faculty of Science, Alexandria University, 21511 Alexandria (Egypt); Grozdanov, D.N. [Frank Laboratory of Neutron Physics, Joint Institute for Nuclear Research, 141980 Dubna (Russian Federation); Institute for Nuclear Research and Nuclear Energy, Bulgarian Academy of Sciences, 1784 Sofia (Bulgaria); Thabet, A.A. [Department of Medical Equipment Technology, Faculty of Allied Medical Sciences, Pharos University in Alexandria (Egypt); Kopatch, Yu.N. [Frank Laboratory of Neutron Physics, Joint Institute for Nuclear Research, 141980 Dubna (Russian Federation); Gouda, M.M. [Physics Department, Faculty of Science, Alexandria University, 21511 Alexandria (Egypt); Skoy, V.R. [Frank Laboratory of Neutron Physics, Joint Institute for Nuclear Research, 141980 Dubna (Russian Federation)

    2015-01-21

    Gamma-ray detector systems are important instruments in a broad range of science and new setup are continually developing. The most recent step in the evolution of detectors for nuclear spectroscopy is the construction of large arrays of detectors of different forms (for example, conical, pentagonal, hexagonal, etc.) and sizes, where the performance and the efficiency can be increased. In this work, a new direct numerical method (NAM), in an integral form and based on the efficiency transfer (ET) method, is used to calculate the full-energy peak efficiency of a single hexagonal NaI(Tl) detector. The algorithms and the calculations of the effective solid angle ratios for a point (isotropic irradiating) gamma-source situated coaxially at different distances from the detector front-end surface, taking into account the attenuation of the gamma-rays in the detector's material, end-cap and the other materials in-between the gamma-source and the detector, are considered as the core of this (ET) method. The calculated full-energy peak efficiency values by the (NAM) are found to be in a good agreement with the measured experimental data.

  8. Application of the dose rate spectroscopy to the dose-to-curie conversion method using a NaI(Tl) detector

    International Nuclear Information System (INIS)

    JI, Young-Yong; Chung, Kun Ho; Kim, Chang-Jong; Kang, Mun Ja; Park, Sang Tae

    2015-01-01

    Dose rate spectroscopy is a very useful method to directly calculate the individual dose rate from the converted energy spectrum for the dose rate using the G-factor which is related to the used detector response function. A DTC conversion method for the estimation of the radioactivity based on the measured dose rate from the radioactive materials can then be modified into a simple equation using the dose rate spectroscopy. In order to make the method validation of the modified DTC conversion method, experimental verifications using a 3″φx3″ NaI(Tl) detector were conducted at the simple geometry of the point source located onto a detector and more complex geometries which mean the assay of the simulated radioactive material. In addition, the linearity about the results from the modified DTC conversion method was also estimated by increasing the distance between source positions and a detector to confirm the method validation in the energy, dose rate, and distance range of the gamma nuclides. - Highlights: • A modified DTC conversion method using the dose rate spectroscopy was established. • In-situ calibration factors were calculated from the MCNP simulation. • Radioactivities of the disk sources were accurately calculated using a modified DTC conversion method. • A modified DTC conversion method was applied to the assay of the radioactive material

  9. Two low-level gamma spectrometry systems of the IAEA Safeguards Analytical Laboratory

    Energy Technology Data Exchange (ETDEWEB)

    Parus, J L [IAEA, SAL, Vienna (Austria); Raab, W [IAEA, SAL, Vienna (Austria); Donohue, D [IAEA, SAL, Vienna (Austria); Jansta, V [IAEA, SAL, Vienna (Austria); Kierzek, J [IAEA, SAL, Vienna (Austria)

    1997-03-01

    A gamma spectrometry system designed for the measurement of samples with low and medium radioactivity (activity from a few to about 10{sup 4} Bq in the energy range from 25 to 2700 keV) has been installed at the IAEA Safeguards Analytical Laboratory in Seibersdorf. The system consists of 3 low level detectors: (1) n-type coaxial Ge with 42.4% relative efficiency, 1.85 keV FWHM at 1.33 MeV (2) planar Ge with 2000 mm{sup 2} area and 20 mm thickness, 562 eV FWHM at 122 keV (3) NaI(Tl) annulus of 25.4 cm diameter and 25.4 cm height, hole diameter 90 mm. (orig./DG)

  10. Use of microcontroller in gamma-ray spectrometer construction using NaI(Tl) sensor, with emphasis in multichannel analyzer, to applications in nuclear and environmental geophysics

    International Nuclear Information System (INIS)

    Silva, Nilton

    2005-01-01

    In this work of nuclear geophysical instrumentation the main purpose was the development of a gamma-ray spectrometer prototype with multi channel analyzer, since the spectroscopic amplifier until your firmware. The heart of the digital part was an ATMEL 8 bits microcontroller (AT89S8252). All circuits were made and assembled in the Laboratory of Applied Geophysical Instrumentation (LIGA) of IAG-USP. A microcontroller software was completely developed in C ANSI language using the Small Device C Compiler version 2.4.8, that is a free software distributed under General Public License (GPL). At first, microcontroller was used to change all digital circuit of one classic SCINTREX GAD-6 differential gamma-ray spectrometer. Measurement times with order of 2 days became possible, and it could work in non climate ambient. Then, after this stage, had been started the development of a multichannel analyzer (MCA) working in pulse height analyzer mode with 4096 channels capacity, to use in many kinds of nuclear detection. Besides it, was developed an automatic gain system for photopeak stabilization, by the use of one radioactive source ( 133 Ba). This automatic gain system is very important in the case of NaI(Tl) scintillometric detectors, due PMT sensitivity with temperature and aging of some laboratory electronic circuits. Two power supplies with high stability, using pulse width modulation (PWM) techniques were developed, in order to all system became free of electrical line break off. One PWM power polarizes a photo multiplier tube (PMT) with high voltage and another supplies remaining developed circuits. Calibration in energy using standards sources 137 Cs and 60 Co showed that gamma detector developed has a good linearity and low thermal drift, even working in absent of air-conditioned. Concentrations measurements of K, U and Th were made in samples of soils, vegetables, etc. (author)'

  11. Calibration and study of the measurement capabilities of real-time gamma spectrometry equipment, developed for the renewal of the network of automatic stations for environmental radiological surveillance of the Generalitat de Catalunya

    International Nuclear Information System (INIS)

    Casanovas, R.; Prieto, E.; Salvado, M.

    2013-01-01

    The renewal of the automatic environmental radiation surveillance network of the Gereralitat of Catalunya has been carried out through the development and implementation of gamma-spectrometry-based equipment. The monitors use scintillation cristals, either NaI(Tl) or LaBr 3 (Ce) and currently, there are 3 types of equipment: water radioactivity monitors, aerosols on a particulate filter monitors and direct measurement monitors. In this paper, we expose the basic features of its operation, the details of their calibration and the minimum detectable activity concentrations for some isotopes

  12. The quick and ultrasensitive determination of K in NaI using inductively coupled plasma mass spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Arnquist, Isaac J., E-mail: isaac.arnquist@pnnl.gov; Hoppe, Eric W.

    2017-04-11

    A highly sensitive, novel and quick assay method utilizing inductively coupled plasma mass spectrometry was developed for the determination of K in NaI powders and NaI(Tl) scintillator crystals for use in ultralow background applications. The determination of K (viz.{sup 40}K), as well as Th and U and their daughters, is important in ultralow background detector materials to ensure incorporation of materials of sufficiently high radiopurity. Through the use of improved instrumentation, cool plasma operating conditions, and meticulously clean sample preparations, detection limits of 11 fg {sup nat}K g{sup −1} (or 341 pBq {sup 40}K kg{sup −1}) was attained for K in pure water. Detection limits in the sample matrix (i.e., NaI) were 0.529 ng {sup nat}K g NaI{sup −1} (or 16.4 μBq {sup 40}K kg NaI{sup −1}). A number of different precursor NaI powder samples and NaI(Tl) scintillator crystals were assayed for their K content. Determinations ranged from 0.757 to 31.4 ng {sup nat}K g NaI{sup −1}. This method allows for the screening of materials to unprecedented levels in a fraction of the time compared to gamma ray counting techniques, providing a useful method for a more effective screening tool of K in ultralow background detector materials.

  13. Concentration dependence of the light yield and energy resolution of NaI:Tl and CsI:Tl crystals excited by gamma, soft X-rays and alpha particles

    CERN Document Server

    Trefilova, L N; Kovaleva, L V; Zaslavsky, B G; Zosim, D I; Bondarenko, S K

    2002-01-01

    Based on the analysis of light yield dependence on activator concentration for NaI:Tl and CsI:Tl excited by gamma-rays, soft X-rays and alpha-particles, an explanation of the effect of energy resolution enhancement with the rise of Tl content has been proposed. Based on the concept regarding the electron track structure, we proposed an alternative explanation of the intrinsic resolution value. The concept does not take into account the non-proportional response to electrons of different energies and is based on the statistic fluctuation of scintillation photon number formed outside and inside the regions of higher ionization density.

  14. Research on digital airborne gamma-ray spectrometry

    International Nuclear Information System (INIS)

    Ge Liangquan; Lai Wanchang; Zeng Guoqiang; Fan Zhenguo; Xiong Shengqing; Ni Weizhong

    2010-01-01

    Airborne Gamma-ray Spectrometry (AGS) is a main supporting technique for looking for uranium deposits and other non-radioactive mineral deposit, as well as for investigating environmental radiation pollution and monitoring nuclear equipment. This paper describes the newest achievements about the AGS instrument developed by Chengdu university of Technology. Those are: 1) the probe of AGS is composed of 5 NaI(Tl) + PMT scintillation counters with 10 x 10 x 40 mm size, and a special temperature sensor, preamplifier with circuit negative feedback and high voltage with lower electronic noise have been designed. 2)A Y/U double channel digital controlled gain amplifier for adjusting the spectrum drift finely and high speed ADC and CPLD are designed to perform digitalized spectroscopy and to improve the energy resolution and pulse through output rate (more than 100k/s). 3) Two self-stabilization spectrum loops have been designed for spectrum stability: The first loop is roughly adjusted by temperature and the second loop is finely by Kalman filter. 4) The significant characters of new AGS system are: the detective gamma energy range is 0.02∼10.0 MeV, the spectrum drift is ±1 channel, the collecting period is 0.5-1 s, and 20 NaI(Tl)+PMT scintillation counters can be operated at the same time. (authors)

  15. Reactor gamma spectrometry: status

    International Nuclear Information System (INIS)

    Gold, R.; Kaiser, B.J.

    1979-01-01

    Current work is described for Compton Recoil Gamma-Ray Spectrometry including developments in experimental technique as well as recent reactor spectrometry measurements. The current status of the method is described concerning gamma spectromoetry probe design and response characteristics. Emphasis is given to gamma spectrometry work in US LWR and BR programs. Gamma spectrometry in BR environments are outlined by focussing on start-up plans for the Fast Test Reactor (FTR). Gamma spectrometry results are presented for a LWR pressure vessel mockup in the Poolside Critical Assembly (PCA) at Oak Ridge National Laboratory

  16. On background radiation gradients – the use of airborne surveys when searching for orphan sources using mobile gamma-ray spectrometry

    International Nuclear Information System (INIS)

    Kock, Peder; Rääf, Christopher; Samuelsson, Christer

    2014-01-01

    Systematic background radiation variations can lead to both false positives and failures to detect an orphan source when searching using car-borne mobile gamma-ray spectrometry. The stochastic variation at each point is well described by Poisson statistics, but when moving in a background radiation gradient the mean count rate will continually change, leading to inaccurate background estimations. Airborne gamma spectrometry (AGS) surveys conducted on the national level, usually in connection to mineral exploration, exist in many countries. These data hold information about the background radiation gradients which could be used at the ground level. This article describes a method that aims to incorporate the systematic as well as stochastic variations of the background radiation. We introduce a weighted moving average where the weights are calculated from existing AGS data, supplied by the Geological Survey of Sweden. To test the method we chose an area with strong background gradients, especially in the thorium component. Within the area we identified two roads which pass through the high-variability locations. The proposed method is compared with an unweighted moving average. The results show that the weighting reduces the excess false positives in the positive background gradients without introducing an excess of failures to detect a source during passage in negative gradients. -- Highlights: • We present a simple method to account for gradients in the natural background radiation. • Gradients in the natural radiation background can be modelled at the ground level using AGS data. • The number of false positives due to background gradients can be reduced by using airborne data

  17. Ground level cosmic ray pulse height spectrum of a 7.5 cm diameter spherical NaI(Tl) scintillation detector for energy region below 5 MeV

    International Nuclear Information System (INIS)

    Nagaoka, Toshi; Saito, Kimiaki; Moriuchi, Shigeru

    1988-01-01

    Ground level cosmic ray pulse height spectrum of a 7.5 cm diameter spherical NaI(Tl) scintillation detector was evaluated through stripping operation based on a pulse height spectrum measured on the sea and high precision response functions of the detector for U-series, Th-series and 40 K. The exposure rate calculated from the determined cosmic ray pulse height spectrum was 0.21 μR/h eq., which agreed well with that obtained from another method. The shape of the pulse height spectrum showed similarity to that measured at the altitude of 16,000 ft, especially in the energy region of 0 to 3 MeV. The principle of the adopted method is rather plain, however, the reliability of the spectrum is satisfactory. As the pulse height spectrum is a common information to any analytical method for environmental gamma ray using NaI(Tl) scintillation detector, it is expected to be used for simple and precise separation of cosmic ray component involved in the enviromental pulse height spectrum. (author)

  18. Use of microcontroller in gamma-ray spectrometer construction using NaI(Tl) sensor, with emphasis in multichannel analyzer, to applications in nuclear and environmental geophysics; Uso de microcontrolador na construcao de espectrometro gama com sensor de NaI(Tl), com enfase em analisador multicanal, para aplicacao em geofisica nuclear e ambiental

    Energy Technology Data Exchange (ETDEWEB)

    Silva, Nilton

    2005-07-01

    In this work of nuclear geophysical instrumentation the main purpose was the development of a gamma-ray spectrometer prototype with multi channel analyzer, since the spectroscopic amplifier until your firmware. The heart of the digital part was an ATMEL 8 bits microcontroller (AT89S8252). All circuits were made and assembled in the Laboratory of Applied Geophysical Instrumentation (LIGA) of IAG-USP. A microcontroller software was completely developed in C ANSI language using the Small Device C Compiler version 2.4.8, that is a free software distributed under General Public License (GPL). At first, microcontroller was used to change all digital circuit of one classic SCINTREX GAD-6 differential gamma-ray spectrometer. Measurement times with order of 2 days became possible, and it could work in non climate ambient. Then, after this stage, had been started the development of a multichannel analyzer (MCA) working in pulse height analyzer mode with 4096 channels capacity, to use in many kinds of nuclear detection. Besides it, was developed an automatic gain system for photopeak stabilization, by the use of one radioactive source ({sup 133}Ba). This automatic gain system is very important in the case of NaI(Tl) scintillometric detectors, due PMT sensitivity with temperature and aging of some laboratory electronic circuits. Two power supplies with high stability, using pulse width modulation (PWM) techniques were developed, in order to all system became free of electrical line break off. One PWM power polarizes a photo multiplier tube (PMT) with high voltage and another supplies remaining developed circuits. Calibration in energy using standards sources {sup 137}Cs and {sup 60}Co showed that gamma detector developed has a good linearity and low thermal drift, even working in absent of air-conditioned. Concentrations measurements of K, U and Th were made in samples of soils, vegetables, etc. (author)'

  19. Methods of neutron spectrometry

    International Nuclear Information System (INIS)

    Doerschel, B.

    1981-01-01

    The different methods of neutron spectrometry are based on the direct measurement of neutron velocity or on the use of suitable energy-dependent interaction processes. In the latter case the measuring effect of a detector is connected with the searched neutron spectrum by an integral equation. The solution needs suitable unfolding procedures. The most important methods of neutron spectrometry are the time-of-flight method, the crystal spectrometry, the neutron spectrometry by use of elastic collisions with hydrogen nuclei, and neutron spectrometry with the aid of nuclear reactions, especially of the neutron-induced activation. The advantages and disadvantages of these methods are contrasted considering the resolution, the measurable energy range, the sensitivity, and the experimental and computational efforts. (author)

  20. Atomic mass spectrometry

    International Nuclear Information System (INIS)

    Sanz-Medel, A.

    1997-01-01

    The elemental inorganic analysis seems to be dominated today by techniques based on atomic spectrometry. After an evaluation of advantages and limitations of using mass analysers (ion detectors) versus conventional photomultipliers (photon detector) a brief review of the more popular techniques of the emerging Atomic Mass spectrometry is carried out. Their huge potential for inorganic trace analysis is such that in the future we could well witness how this end of the century and millennium marked the fall of the photons empire in Analytical Atomic Spectrometry. (Author)

  1. Calibration and study of the measurement capabilities of real-time gamma spectrometry equipment, developed for the renewal of the network of automatic stations for environmental radiological surveillance of the Generalitat de Catalunya; Calibracion y estudio de las capacidades de medida de loes equipos de espectrometria gamma en tiempo real desarrollados para la renovacion de la Red de Estaciones Automaticas de vigencia radiologica ambiental de la generalitat de Catalunya

    Energy Technology Data Exchange (ETDEWEB)

    Casanovas, R.; Prieto, E.; Salvado, M.

    2013-07-01

    The renewal of the automatic environmental radiation surveillance network of the Gereralitat of Catalunya has been carried out through the development and implementation of gamma-spectrometry-based equipment. The monitors use scintillation cristals, either NaI(Tl) or LaBr{sub 3}(Ce) and currently, there are 3 types of equipment: water radioactivity monitors, aerosols on a particulate filter monitors and direct measurement monitors. In this paper, we expose the basic features of its operation, the details of their calibration and the minimum detectable activity concentrations for some isotopes.

  2. Software for nuclear spectrometry

    International Nuclear Information System (INIS)

    1998-10-01

    The Advisory Group Meeting (AGM) on Software for Nuclear Spectrometry was dedicated to review the present status of software for nuclear spectrometry and to advise on future activities in this field. Because similar AGM and consultant's meetings had been held in the past; together with an attempt to get more streamlined, this AGM was devoted to the specific field of software for gamma ray spectrometry. Nevertheless, many of the issues discussed and the recommendations made are of general concern for any software on nuclear spectrometry. The report is organized by sections. The 'Summary' gives conclusions and recommendations adopted at the AGM. These conclusions and recommendations resulted from the discussions held during and after presentations of the scientific and technical papers. These papers are reported here in their integral form in the following Sections

  3. Glycomics using mass spectrometry

    OpenAIRE

    Wuhrer, Manfred

    2013-01-01

    Mass spectrometry plays an increasingly important role in structural glycomics. This review provides an overview on currently used mass spectrometric approaches such as the characterization of glycans, the analysis of glycopeptides obtained by proteolytic cleavage of proteins and the analysis of glycosphingolipids. The given examples are demonstrating the application of mass spectrometry to study glycosylation changes associated with congenital disorders of glycosylation, lysosomal storage di...

  4. Ion mobility spectrometry

    CERN Document Server

    Eiceman, GA

    2005-01-01

    Key Developments for Faster, More Precise Detection Capabilities Driven by the demand for the rapid and advanced detection of explosives, chemical and biological warfare agents, and narcotics, ion mobility spectrometry (IMS) undergone significant refinements in technology, computational capabilities, and understanding of the principles of gas phase ion chemistry and mobility. Beginning with a thorough discussion of the fundamental theories and physics of ion mobility, Ion Mobility Spectrometry, Second Edition describes the recent advances in instrumentation and newly

  5. Forensic Mass Spectrometry

    Science.gov (United States)

    Hoffmann, William D.; Jackson, Glen P.

    2015-07-01

    Developments in forensic mass spectrometry tend to follow, rather than lead, the developments in other disciplines. Examples of techniques having forensic potential born independently of forensic applications include ambient ionization, imaging mass spectrometry, isotope ratio mass spectrometry, portable mass spectrometers, and hyphenated chromatography-mass spectrometry instruments, to name a few. Forensic science has the potential to benefit enormously from developments that are funded by other means, if only the infrastructure and personnel existed to adopt, validate, and implement the new technologies into casework. Perhaps one unique area in which forensic science is at the cutting edge is in the area of chemometrics and the determination of likelihood ratios for the evaluation of the weight of evidence. Such statistical techniques have been developed most extensively for ignitable-liquid residue analyses and isotope ratio analysis. This review attempts to capture the trends, motivating forces, and likely impact of developing areas of forensic mass spectrometry, with the caveat that none of this research is likely to have any real impact in the forensic community unless: (a) The instruments developed are turned into robust black boxes with red and green lights for positives and negatives, respectively, or (b) there are PhD graduates in the workforce who can help adopt these sophisticated techniques.

  6. Fourier Transform Mass Spectrometry

    Science.gov (United States)

    Scigelova, Michaela; Hornshaw, Martin; Giannakopulos, Anastassios; Makarov, Alexander

    2011-01-01

    This article provides an introduction to Fourier transform-based mass spectrometry. The key performance characteristics of Fourier transform-based mass spectrometry, mass accuracy and resolution, are presented in the view of how they impact the interpretation of measurements in proteomic applications. The theory and principles of operation of two types of mass analyzer, Fourier transform ion cyclotron resonance and Orbitrap, are described. Major benefits as well as limitations of Fourier transform-based mass spectrometry technology are discussed in the context of practical sample analysis, and illustrated with examples included as figures in this text and in the accompanying slide set. Comparisons highlighting the performance differences between the two mass analyzers are made where deemed useful in assisting the user with choosing the most appropriate technology for an application. Recent developments of these high-performing mass spectrometers are mentioned to provide a future outlook. PMID:21742802

  7. Ambient ionization mass spectrometry

    International Nuclear Information System (INIS)

    Lebedev, A T

    2015-01-01

    Ambient ionization mass spectrometry emerged as a new scientific discipline only about ten years ago. A considerable body of information has been reported since that time. Keeping the sensitivity, performance and informativity of classical mass spectrometry methods, the new approach made it possible to eliminate laborious sample preparation procedures and triggered the development of miniaturized instruments to work directly in the field. The review concerns the theoretical foundations and design of ambient ionization methods. Their advantages and drawbacks, as well as prospects for application in chemistry, biology, medicine, environmetal analysis, etc., are discussed. The bibliography includes 194 references

  8. Miniaturization and Mass Spectrometry

    NARCIS (Netherlands)

    le Gac, S.; le Gac, Severine; van den Berg, Albert; van den Berg, A.; Unknown, [Unknown

    2009-01-01

    With this book we want to illustrate how two quickly growing fields of instrumentation and technology, both applied to life sciences, mass spectrometry and microfluidics (or microfabrication) naturally came to meet at the end of the last century and how this marriage impacts on several types of

  9. Fourier Transform Mass Spectrometry.

    Science.gov (United States)

    Gross, Michael L.; Rempel, Don L.

    1984-01-01

    Discusses the nature of Fourier transform mass spectrometry and its unique combination of high mass resolution, high upper mass limit, and multichannel advantage. Examines its operation, capabilities and limitations, applications (ion storage, ion manipulation, ion chemistry), and future applications and developments. (JN)

  10. Analytical mass spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    1990-01-01

    This 43rd Annual Summer Symposium on Analytical Chemistry was held July 24--27, 1990 at Oak Ridge, TN and contained sessions on the following topics: Fundamentals of Analytical Mass Spectrometry (MS), MS in the National Laboratories, Lasers and Fourier Transform Methods, Future of MS, New Ionization and LC/MS Methods, and an extra session. (WET)

  11. Analytical mass spectrometry. Abstracts

    Energy Technology Data Exchange (ETDEWEB)

    1990-12-31

    This 43rd Annual Summer Symposium on Analytical Chemistry was held July 24--27, 1990 at Oak Ridge, TN and contained sessions on the following topics: Fundamentals of Analytical Mass Spectrometry (MS), MS in the National Laboratories, Lasers and Fourier Transform Methods, Future of MS, New Ionization and LC/MS Methods, and an extra session. (WET)

  12. Characterization of radioactive orphan sources by gamma spectrometry; Caracterizacion de fuentes huerfanas radiactivas por espectrometria gamma

    Energy Technology Data Exchange (ETDEWEB)

    Cruz W, H., E-mail: wcruz@ipen.gob.pe [Instituto Peruano de Energia Nuclear (PGRR/IPEN), Lima (Peru). Planta de Gestion de Residuos Radiactivos

    2013-07-01

    The sealed radioactive sources are widely applicable in industry. They must have a permanent control and must be registered with the Technical Office of the National Authority (OTAN). However, at times it has identified the presence of abandoned sealed sources unknown to the owner. These sources are called 'orphan sources'. Of course these sources represent a high potential risk because accidents can trigger dire consequences depending on your activity and chemical form in which it presents the radioisotope. This paper describes the process and the actions taken to characterize two orphan radioactive sources from the smelter a Aceros Arequipa. For characterization we used a gamma spectrometry system using a detector NaI(Tl) 3″ x 3″ with a multichannel analyzer Nucleus PCA-II. The radioisotope identified was cesium - 137 ({sup 137}Cs) in both cases. Fortunately, the sources maintained their integrity would otherwise have generated significant pollution considering the chemical form of the radioisotope and easy dispersion. (author)

  13. Application of simulated standard spectra in natural radioactivity measurements using gamma spectrometry

    International Nuclear Information System (INIS)

    Narayani, K.; Pant, A.D.; Bhosle, Nitin; Anilkumar, S.; Singh, Rajvir; Pradeepkumar, K.S.

    2014-01-01

    Gamma ray spectrometry is one of the well known analytical techniques for environmental radioactivity measurements. Gamma spectrometer based on NaI(Tl) scintillation detectors is very popular since it offers high efficiency, low cost and case in handling. The poor energy resolution of the NaI(TI) detector is the major disadvantage making tile analysis of complex gamma ray spectra difficult. Least square method or the full spectrum analysis method is widely used for the analysis of complex spectra from scintillation detectors. The main requirement of this method is that the individual standard spectra of all nuclides expected in the complex spectrum in the same measurement geometry must be available. It is not always possible and feasible to have all the standards of nuclides in the desired geometry. A methodology based on the use of simulated standard spectra generated by Monte Carlo technique was proposed for analysis of complex spectra of nuclides. In the present work, for the analysis of 238 U, 233 Th and 40 K in soil samples, the same methodology was applied by using the simulated standard spectra in soil matrix. The details of the simulation method and results analysis of 238 U, 232 Th and 40 K in environmental samples are discussed in this paper

  14. Estimation of natural potassium concentration in Romanian males by in vivo gamma-ray spectrometry measurements

    International Nuclear Information System (INIS)

    Mirela Angela Saizu

    2012-01-01

    At the Whole Body Monitoring Laboratory, from IFIN-HH, Bucharest, Romania, there were performed in vivo gamma-ray spectrometry measurements on 108 Romanian males in order to evaluate the mineral natural potassium content in human body, as total value and concentration. The measurements were performed with a shadow shield whole body counter, tilted chair geometry, based on a shielded NaI(Tl) scintillation detector of 12.5 cm (diameter) x 10 cm (height) crystal size. The results revealed a calculated value of the mean total body potassium (TBK) of 135.03 ± 2.94 g and a value of 1.9 ± 0.022 g of potassium/kg of body weight for the mean body potassium concentration, for the measured males. These values are similar with the values declared for the Reference Man, in ICRP23. Correlations between total body potassium, potassium concentration and age, weight and Body Build Index were investigated and peculiar conclusions were resulted. (author)

  15. Development and application of portable mobile gamma spectrometry system (PMGSS) for realtime online radiological assessment

    International Nuclear Information System (INIS)

    Patil, S.S.; Padmanabhan, N.; Sharma, R.; Singh, R.; Pradeepkumar, K.S.

    2008-01-01

    A state of art mobile monitoring system is a prime requirement to combat the challenging radiological situations. In the event of any radiological/nuclear Emergencies an effective, realistic methodology of radiological measurements is an asset. In this context, a highly sensitive real-time online mobile monitoring system having features and provision to display the important parameters will be an essential tool in the course of radiological impact assessment. This paper, describes the efforts that has been made towards providing a useful Portable Mobile Gamma Spectrometry System (PMGSS) and developing applications so as to enhance its usefulness in quick radiological impact assessment and to initiate the proper countermeasures during any Nuclear/Radiological emergency situation in public domain. The system uses a NaI(Tl) detector, a global positioning system (GPS) and a laptop PC for storage, analysis and graphical representation of the acquired data. PMGSS is a highly sensitive, portable and reliable radiation monitoring equipment with capability of qualitative and quick estimation of the radioisotopes. The system was used for the mobile radiological mapping of Bangalore and Mumbai city and demonstrated its capability for use in environmental radiation monitoring during any radiological emergency requirement the results of which are presented here. (abstract)

  16. Burn up determination of IEAR-1 fuel elements by non destructive gamma ray spectrometry method

    International Nuclear Information System (INIS)

    Soares, A.J.

    1977-01-01

    Measurement of nuclear fuel burn up by non destructive gamma ray spectrometry is discussed, and results of such measurements, made at the Instituto de Energia Atomica (IEA), are given. Specifically, the burn up of an MTR (Material Testing Reactor) fuel element removed from the IEAR-1 swimming pool reactor in 1958 is evaluated from the measured Cs-137 activity, which gives a single 661,6 keV gamma ray. Due to the long decay time of the test element, no other fission decay product activity could be detected. Analysis of measurements, made with a 3'' x 3'' NaI(Tl) detector at 330 distinct points of the element, showed the total burn up to 3.3 +- -+ 0.8 mg. This is in agreement with a calculated value. As the maximum temperature of IEAR-1 fuel elements is of the order of 40 0 C, migration effects of Cs-137 was not considered, this being significant only at fuel temperature in excess of 1000 0 C [pt

  17. In-phantom spectrometry of medical diagnostic x rays

    International Nuclear Information System (INIS)

    Stansbury, P.S.

    1977-10-01

    A program of measurements was made to determine the spectral fluence distributions at locations of significance in a heterogeneous, hominoid phantom exposed to x rays in a manner simulating medical diagnostic radiology. The measurements were made with a specially constructed NaI(Tl) scintillation detector. The detector had a spherically shaped active volume 0.6 cm in diameter. The resolution of this detector was five times worse than that of a more conventional NaI(Tl) spectrometer. Resolution broadening and other distortions were removed from the observed pulse height spectra with a computer-coded, iterative unfolding technique. The performance of the spectrometer and the unfolding scheme was assessed by comparing, in a few cases, the unfolded NaI(Tl) spectra with spectra determined with a high resolution Ge(Li) spectrometer. The measurements were made in a physical model of an idealized representation of an average adult patient

  18. In-phantom spectrometry of medical diagnostic x rays

    Energy Technology Data Exchange (ETDEWEB)

    Stansbury, P. S.

    1977-10-01

    A program of measurements was made to determine the spectral fluence distributions at locations of significance in a heterogeneous, hominoid phantom exposed to x rays in a manner simulating medical diagnostic radiology. The measurements were made with a specially constructed NaI(Tl) scintillation detector. The detector had a spherically shaped active volume 0.6 cm in diameter. The resolution of this detector was five times worse than that of a more conventional NaI(Tl) spectrometer. Resolution broadening and other distortions were removed from the observed pulse height spectra with a computer-coded, iterative unfolding technique. The performance of the spectrometer and the unfolding scheme was assessed by comparing, in a few cases, the unfolded NaI(Tl) spectra with spectra determined with a high resolution Ge(Li) spectrometer. The measurements were made in a physical model of an idealized representation of an average adult patient.

  19. Mass spectrometry in oceanography

    International Nuclear Information System (INIS)

    Aggarwal, Suresh K.

    2000-01-01

    Mass spectrometry plays an important role in oceanography for various applications. Different types of inorganic as well as organic mass spectrometric techniques are being exploited world-wide to understand the different aspects of marine science, for palaeogeography, palaeoclimatology and palaeoecology, for isotopic composition and concentrations of different elements as well as for speciation studies. The present paper reviews some of the applications of atomic mass spectrometric techniques in the area of oceanography

  20. Hydrogen Exchange Mass Spectrometry

    Science.gov (United States)

    Mayne, Leland

    2018-01-01

    Hydrogen exchange (HX) methods can reveal much about the structure, energetics, and dynamics of proteins. The addition of mass spectrometry (MS) to an earlier fragmentation-separation HX analysis now extends HX studies to larger proteins at high structural resolution and can provide information not available before. This chapter discusses experimental aspects of HX labeling, especially with respect to the use of MS and the analysis of MS data. PMID:26791986

  1. Mass spectrometry with accelerators.

    Science.gov (United States)

    Litherland, A E; Zhao, X-L; Kieser, W E

    2011-01-01

    As one in a series of articles on Canadian contributions to mass spectrometry, this review begins with an outline of the history of accelerator mass spectrometry (AMS), noting roles played by researchers at three Canadian AMS laboratories. After a description of the unique features of AMS, three examples, (14)C, (10)Be, and (129)I are given to illustrate the methods. The capabilities of mass spectrometry have been extended by the addition of atomic isobar selection, molecular isobar attenuation, further ion acceleration, followed by ion detection and ion identification at essentially zero dark current or ion flux. This has been accomplished by exploiting the techniques and accelerators of atomic and nuclear physics. In 1939, the first principles of AMS were established using a cyclotron. In 1977 the selection of isobars in the ion source was established when it was shown that the (14)N(-) ion was very unstable, or extremely difficult to create, making a tandem electrostatic accelerator highly suitable for assisting the mass spectrometric measurement of the rare long-lived radioactive isotope (14)C in the environment. This observation, together with the large attenuation of the molecular isobars (13)CH(-) and (12)CH 2(-) during tandem acceleration and the observed very low background contamination from the ion source, was found to facilitate the mass spectrometry of (14)C to at least a level of (14)C/C ~ 6 × 10(-16), the equivalent of a radiocarbon age of 60,000 years. Tandem Accelerator Mass Spectrometry, or AMS, has now made possible the accurate radiocarbon dating of milligram-sized carbon samples by ion counting as well as dating and tracing with many other long-lived radioactive isotopes such as (10)Be, (26)Al, (36)Cl, and (129)I. The difficulty of obtaining large anion currents with low electron affinities and the difficulties of isobar separation, especially for the heavier mass ions, has prompted the use of molecular anions and the search for alternative

  2. Remote and continuous gamma spectrometry for environmental radiation protection: A review of potential applications

    International Nuclear Information System (INIS)

    Put, Ph. V.; Debauche, A.; Lacroix, J-P.; Lellis, C. D.; Delecaut, G.

    2006-01-01

    The first nuclear metrology tools for surface water surveillance have been designed in the early 80's. The detection systems were based on the use of a NaI(Tl) detector connected to two Single Channel Analyzers (SCA). The detector was placed in a shielded vessel fed with the water to be analysed through a pump. The analysis was rudimentary. The systems were suffering the inherent temperature drift from the detector. For this reasons the system required frequent maintenance for the mechanical parts and the detection system calibration. The sensitivity of the system was about 10-100 Bq/l, which make it useful for monitoring accidental releases from base nuclear installations. Technical evolutions in the fields of computer sciences and telecommunication have allowed the IRE to develop an original instrument able to detect and to quantify very small radioactivity increase in surface water. The system is based on a NaI(Tl) detector connected to a multi-channel analyzer. The detection system is now directly placed in the medium to survey. The analysis is performed using gamma spectrometry technique. In this way the detector temperature drift is compensated thanks to a special algorithm, the spectral analysis permits to discriminate natural and artificial radioactivity and the detection system is much more sensitive. The design of the detection system without pump make feasible to feed it with solar energy and consequently to install it in any aquatic environment (sea, lake ...). The need for regular maintenance is reduced considerably. This system has been successfully implemented in sea and river waters. The system stability is unique for NaI(Tl) based detection system. The detection limit has been considerably lowered - for 1 37Cs in seawater - containing 12 Bq/l of 4 0K - it is in the range 0.13-0.22 Bq/l for a 2-hours measurement, while it is in the range 0.65-0.85 Bq/l for a 2-hours counting time in river water. The reported detection limit in river water is higher

  3. The applications of vehicle borne and ground gamma ray spectrometry in environmental radioactivity survey and monitoring: examples from the Philippines

    International Nuclear Information System (INIS)

    Reyes, R.Y.; Petrache, C.A.; Garcia, N.Q.; Tabora, E.U.; Juson, J.G.

    2002-01-01

    In the light of the nuclear development all over the world, there is an increasing global awareness on matters related to radioactivity and radioactive accidents. As such, the Philippine Nuclear Research Institute (PNRI) acquired through a technical cooperation project with the International Atomic Energy Agency the vehicle borne (car borne) and portable (ground) gamma ray, spectrometers. The objectives of this project were to establish environmental baseline information on the natural radioactivity of the entire country and to generate radioelement maps for geological mapping and mineral resource assessment. The purpose of this paper is to present the results of the different surveys including the methodologies and techniques conducted in the country using both spectrometers in effectively mapping natural and man-made sources of radiation. A pilot survey was successfully carried out over the small island of Marinduque (989 km 2 ) using the combined car borne and ground gamma ray spectrometric survey techniques. This was in preparation of the planned nationwide survey using this approach. Highlight of this study was the production of the first natural radioactivity maps within the country. Interestingly, these maps closely reflect the local geology of Marinduque Island. Car borne gamma ray spectrometric surveys were likewise undertaken at the former US naval base in Subic and US airforce base in Clark. This was due to mounting public concern over the presence of possible radioactive contamination or materials left behind by the US military forces in these bases. Results using the gamma-ray spectrum ratio technique indicated the absence of man-made sources of radiation in areas monitored within the two bases. A sizeable part of Metro Manila, the capital of the Philippines, has also been covered by the car borne survey. Results discovered an area with high measurements of thorium. The radiation source is coming from an establishment that uses thorium nitrate in

  4. Mass spectrometry in clinical chemistry

    International Nuclear Information System (INIS)

    Pettersen, J.E.

    1977-01-01

    A brief description is given of the functional elements of a mass spectrometer and of some currently employed mass spectrometric techniques, such as combined gas chromatography-mass spectrometry, mass chromatography, and selected ion monitoring. Various areas of application of mass spectrometry in clinical chemistry are discussed, such as inborn errors of metabolism and other metabolic disorders, intoxications, quantitative determinations of drugs, hormones, gases, and trace elements, and the use of isotope dilution mass spectrometry as a definitive method for the establishment of true values for concentrations of various compounds in reference sera. It is concluded that mass spectrometry is of great value in clinical chemistry. (Auth.)

  5. Sample Preprocessing For Atomic Spectrometry

    International Nuclear Information System (INIS)

    Kim, Sun Tae

    2004-08-01

    This book gives descriptions of atomic spectrometry, which deals with atomic absorption spectrometry such as Maxwell-Boltzmann equation and Beer-Lambert law, atomic absorption spectrometry for solvent extraction, HGAAS, ETASS, and CVAAS and inductively coupled plasma emission spectrometer, such as basic principle, generative principle of plasma and device and equipment, and interferences, and inductively coupled plasma mass spectrometry like device, pros and cons of ICP/MS, sample analysis, reagent, water, acid, flux, materials of experiments, sample and sampling and disassembling of sample and pollution and loss in open system and closed system.

  6. Alpha spectrometry and secondary ion mass spectrometry of thorium

    International Nuclear Information System (INIS)

    Strisovska, Jana; Kuruc, Jozef; Galanda, Dusan; Matel, Lubomir; Velic, Dusan; Aranyosiova, Monika

    2009-01-01

    A sample of thorium content on steel discs was prepared by electrodeposition with a view to determining the natural thorium isotope. Thorium was determined by alpha spectrometry and by secondary ion mass spectrometry and the results of the two methods were compared

  7. Nanoscience, nanotechnology and spectrometry

    International Nuclear Information System (INIS)

    Adams, Freddy C.; Barbante, Carlo

    2013-01-01

    Nanoscience has outgrown its infancy, and nanotechnology has found important applications in our daily life — with many more to come. Although the central concepts of the nano world, namely the changes of particular physical properties on the length scale of individual atoms and molecules, have been known and developed for quite some time already, experimental advances since the 1980s and recognition of the potential of nanomaterials led to a genuine breakthrough of the inherently multidisciplinary nanoscience field. Analytical nanoscience and nanotechnology and especially the use of micro and nano electro mechanical systems, of the quantum dots and of mass spectrometry, currently provide one of the most promising avenues for developments in analytical science, derived from their two main fields of action, namely (a) the analysis of nano-structured materials and (b) their use as new tools for analysis. An overview is given of recent developments and trends in the field, highlighting the importance and point out future directions, while also touching drawbacks, such as emerging concerns about health and environmental issues. - Highlights: • We review the analysis of nano-structured materials. • Nano-structured materials can be used as new tools for analysis. • Use of nano electro mechanical systems, of quantum dots and of mass spectrometry • Nanotechnologies are among the most promising tools in analytical science

  8. Nanoscience, nanotechnology and spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Adams, Freddy C. [Department of Chemistry, University of Antwerp, B-2610 Wilrijk (Belgium); Barbante, Carlo, E-mail: barbante@unive.it [Institute for the Dynamics of Environmental Processes — CNR, Venice (Italy); Department of Environmental Sciences, Informatics and Statistics, Ca' Foscari University, Venice (Italy)

    2013-08-01

    Nanoscience has outgrown its infancy, and nanotechnology has found important applications in our daily life — with many more to come. Although the central concepts of the nano world, namely the changes of particular physical properties on the length scale of individual atoms and molecules, have been known and developed for quite some time already, experimental advances since the 1980s and recognition of the potential of nanomaterials led to a genuine breakthrough of the inherently multidisciplinary nanoscience field. Analytical nanoscience and nanotechnology and especially the use of micro and nano electro mechanical systems, of the quantum dots and of mass spectrometry, currently provide one of the most promising avenues for developments in analytical science, derived from their two main fields of action, namely (a) the analysis of nano-structured materials and (b) their use as new tools for analysis. An overview is given of recent developments and trends in the field, highlighting the importance and point out future directions, while also touching drawbacks, such as emerging concerns about health and environmental issues. - Highlights: • We review the analysis of nano-structured materials. • Nano-structured materials can be used as new tools for analysis. • Use of nano electro mechanical systems, of quantum dots and of mass spectrometry • Nanotechnologies are among the most promising tools in analytical science.

  9. Preface Miniaturization and Mass Spectrometry

    NARCIS (Netherlands)

    Unknown, [Unknown; le Gac, Severine; le Gac, S.; van den Berg, Albert; van den Berg, A.

    2009-01-01

    Miniaturization and Mass Spectrometry illustrates this trend and focuses on one particular analysis technique, mass spectrometry whose popularity has "dramatically" increased in the last two decades with the explosion of the field of biological analysis and the development of two "soft" ionization

  10. Negative chemical ionization mass spectrometry

    International Nuclear Information System (INIS)

    Smit, A.L.C.

    1979-01-01

    This thesis describes some aspects of Negative Chemical Ionization (NCI) mass spectrometry. The reasons for the growing interest in NCI are: (i) to extend the basic knowledge of negative ions and their reactions in the gas phase; (ii) to investigate whether or not this knowledge of negative ions can be used successfully to elucidate the structure of molecules by mass spectrometry. (Auth.)

  11. Laboratory of acceleration mass spectrometry

    International Nuclear Information System (INIS)

    Hybler, P.; Chrapan, J.

    2002-01-01

    In this paper authors describe the principle of the method of acceleration mass spectrometry and the construction plans of this instrument at the Faculty of ecology and environmental sciences in Banska Stiavnica. Using of this instrument for radiocarbon dating is discussed. A review of laboratories with acceleration mass spectrometry is presented

  12. Accelerator-based ultrasensitive mass spectrometry

    International Nuclear Information System (INIS)

    Gove, H.E.

    1985-01-01

    This chapter describes a new mass spectrometry technique involving charged particle accelerators normally used for basic research in nuclear science. Topics considered include the limitations of conventional mass spectrometry, the limitations of the direct measurement of radioactive decay, mass spectrometry using a tandem electrostatic accelerator, mass spectrometry using a cyclotron, how accelerator mass spectrometry circumvents the limitations of conventional mass spectrometry, measurements of stable isotopes, nuclear physics and astrophysics applications, modifications to existing accelerators, descriptions of dedicated systems, and future applications

  13. Method for calibration of the NaI(Tl) 3''x 3'' detector for in vivo measurements in patients undergoing radioiodine therapy and occupationally exposed individuals to 131I

    International Nuclear Information System (INIS)

    Xavier, A.C.S.; Oliveira, M.L.; Lima, F.F.; Lima, F.R.A.; Lacerda, I.V.B.; Universidade Federal de Pernambuco

    2012-01-01

    According to studies by the Instituto Nacional do Cancer (INCA), in recent years the incidence of thyroid cancer is the fastest growing in relation to other types. For the treatment is required the exact amount of 131 I isotope for each patient resulting on manipulation of this isotope in nuclear medicine services by individuals who are considered occupationally exposed (OEI). This work aims to establish the methodology for calibration of the detection system used to determine the therapeutic activity of 131 I, required to release the desired absorbed dose in the thyroid gland, as well as in monitoring OEI that manipulate this radionuclide in nuclear medicine services. This is one of the early stages of implementation of Laboratorio de Dosimetria Interna at the Centro Regional de Ciencias Nucleares do Nordeste (CRCN-NE). The detector system consists of a NaI(Tl) 3'' x 3'' associated with electronic devices and Genie 2000 software. Sources of 60 Co, 137 Cs and 133 Ba were utilized for calibration. Firstly, measurements were carried out in non-exposed individuals for obtaining the Minimum Detectable Activity (MDA) and then Minimum Detectable Incorporation (MDI) and the Minimum Effective Dose Detectable (MEDD) were determined through biokinetic models provided by the ICRP 67 and edited by the AIDE software version 6 to workers and patients. The values for the MEDD were 3.57 x 10 -2 mSv, 5.56 x 10 -2 mSv and 10.7 x 10 -2 mSv to 1, 7 and 14 days, respectively, after 131 I incorporation by workers. As for patients, MEDD were 3.44 x 10 -2 mSv, 5.63 x 10 -2 mSv and 10.9 x 10 -2 mSv for the same periods of time. It is applicable to the assessment of dose OEI, since it presents less than the recommended minimum of 1 mSv. The technique also has adequate sensitivity for evaluation of activity present in the thyroid of patients with thyroid dysfunction. (author)

  14. Spectrometry techniques for radioactivity measurements

    International Nuclear Information System (INIS)

    Anilkumar, S.

    2016-01-01

    The energy of the radiation emission following the nuclear decay is unique and the characteristic of the radio nuclide which undergoes decay. Thus measurement of the energy of the radiation offers a method of identifying the radio nuclides. The prime requirement of the energy measurement is a suitable detector which shows response proportional to the energy of the radiation rather than the presence of the radiation. The response from such detectors are suitably processed and distributed with respect to the signal strength which is proportional to incident energy. This distribution is normally referred as energy spectrum and is recorded in the multichannel analyser. The measurement of energy and intensity of radiation from the spectrum is called radiation spectrometry. Thus the radiation spectrometry allows the identification and quantification of radioactive isotopes in variety of matrices. The radiation spectrometry has now become a popular radioanalytical technique in wide area of nuclear fuel cycle programs. The popular spectrometry techniques commonly used for the radioactivity measurement and analysis are Alpha spectrometry, Gamma ray spectrometry and Beta spectrometry

  15. Imaging mass spectrometry statistical analysis.

    Science.gov (United States)

    Jones, Emrys A; Deininger, Sören-Oliver; Hogendoorn, Pancras C W; Deelder, André M; McDonnell, Liam A

    2012-08-30

    Imaging mass spectrometry is increasingly used to identify new candidate biomarkers. This clinical application of imaging mass spectrometry is highly multidisciplinary: expertise in mass spectrometry is necessary to acquire high quality data, histology is required to accurately label the origin of each pixel's mass spectrum, disease biology is necessary to understand the potential meaning of the imaging mass spectrometry results, and statistics to assess the confidence of any findings. Imaging mass spectrometry data analysis is further complicated because of the unique nature of the data (within the mass spectrometry field); several of the assumptions implicit in the analysis of LC-MS/profiling datasets are not applicable to imaging. The very large size of imaging datasets and the reporting of many data analysis routines, combined with inadequate training and accessible reviews, have exacerbated this problem. In this paper we provide an accessible review of the nature of imaging data and the different strategies by which the data may be analyzed. Particular attention is paid to the assumptions of the data analysis routines to ensure that the reader is apprised of their correct usage in imaging mass spectrometry research. Copyright © 2012 Elsevier B.V. All rights reserved.

  16. Method for calibration of the NaI(Tl) 3''x 3'' detector for in vivo measurements in patients undergoing radioiodine therapy and occupationally exposed individuals to {sup 131}I; Metodologia para calibracao do detector de NaI(Tl) 3''x 3''para medicoes in vivo em pacientes submetidos a radioiodoterapia e individuos ocupacionalmente expostos ao {sup 131}I

    Energy Technology Data Exchange (ETDEWEB)

    Xavier, A.C.S.; Oliveira, M.L.; Lima, F.F.; Lima, F.R.A. [Centro Regional de Ciencias Nucleares do Nordeste (CRCN-NE/CNEN-PE), Recife, PE (Brazil); Lacerda, I.V.B., E-mail: line_c7@hotmail.com [Centro Regional de Ciencias Nucleares do Nordeste (CRCN-NE/CNEN-PE), Recife, PE (Brazil); Universidade Federal de Pernambuco (UFPE), Recife, PE (Brazil). Programa de Pos-Graduacao em Tecnologias Energeticas e Nucleares

    2012-07-01

    According to studies by the Instituto Nacional do Cancer (INCA), in recent years the incidence of thyroid cancer is the fastest growing in relation to other types. For the treatment is required the exact amount of {sup 131}I isotope for each patient resulting on manipulation of this isotope in nuclear medicine services by individuals who are considered occupationally exposed (OEI). This work aims to establish the methodology for calibration of the detection system used to determine the therapeutic activity of {sup 131}I, required to release the desired absorbed dose in the thyroid gland, as well as in monitoring OEI that manipulate this radionuclide in nuclear medicine services. This is one of the early stages of implementation of Laboratorio de Dosimetria Interna at the Centro Regional de Ciencias Nucleares do Nordeste (CRCN-NE). The detector system consists of a NaI(Tl) 3'' x 3'' associated with electronic devices and Genie 2000 software. Sources of {sup 60}Co, {sup 137}Cs and {sup 133}Ba were utilized for calibration. Firstly, measurements were carried out in non-exposed individuals for obtaining the Minimum Detectable Activity (MDA) and then Minimum Detectable Incorporation (MDI) and the Minimum Effective Dose Detectable (MEDD) were determined through biokinetic models provided by the ICRP 67 and edited by the AIDE software version 6 to workers and patients. The values for the MEDD were 3.57 x 10{sup -2} mSv, 5.56 x 10{sup -2} mSv and 10.7 x 10{sup -2} mSv to 1, 7 and 14 days, respectively, after {sup 131}I incorporation by workers. As for patients, MEDD were 3.44 x 10{sup -2} mSv, 5.63 x 10{sup -2} mSv and 10.9 x 10{sup -2} mSv for the same periods of time. It is applicable to the assessment of dose OEI, since it presents less than the recommended minimum of 1 mSv. The technique also has adequate sensitivity for evaluation of activity present in the thyroid of patients with thyroid dysfunction. (author)

  17. X-ray spectrometry

    International Nuclear Information System (INIS)

    Markowicz, A.A.; Van Grieken, R.E.

    1986-01-01

    In the period under review, i.e, through 1984 and 1985, some 600 articles on XRS (X-ray spectrometry) were published; most of these have been scanned and the most fundamental ones are discussed. All references will refer to English-language articles, unless states otherwise. Also general books have appeared on quantitative EPXMA (electron-probe X-ray microanalysis) and analytical electron microscopy (AEM) as well as an extensive review on the application of XRS to trace analysis of environmental samples. In the period under review no radically new developments have been seen in XRS. However, significant improvements have been made. Gain in intensities has been achieved by more efficient excitation, higher reflectivity of dispersing media, and better geometry. Better understanding of the physical process of photon- and electron-specimen interactions led to complex but more accurate equations for correction of various interelement effects. Extensive use of micro- and minicomputers now enables fully automatic operation, including qualitative analysis. However, sample preparation and presentation still put a limit to further progress. Although some authors find XRS in the phase of stabilization or even stagnation, further gradual developments are expected, particularly toward more dedicated equipment, advanced automation, and image analysis systems. Ways are outlined in which XRS has been improved in the 2 last years by excitation, detection, instrumental, methodological, and theoretical advances. 340 references

  18. Accelerator mass spectrometry.

    Science.gov (United States)

    Hellborg, Ragnar; Skog, Göran

    2008-01-01

    In this overview the technique of accelerator mass spectrometry (AMS) and its use are described. AMS is a highly sensitive method of counting atoms. It is used to detect very low concentrations of natural isotopic abundances (typically in the range between 10(-12) and 10(-16)) of both radionuclides and stable nuclides. The main advantages of AMS compared to conventional radiometric methods are the use of smaller samples (mg and even sub-mg size) and shorter measuring times (less than 1 hr). The equipment used for AMS is almost exclusively based on the electrostatic tandem accelerator, although some of the newest systems are based on a slightly different principle. Dedicated accelerators as well as older "nuclear physics machines" can be found in the 80 or so AMS laboratories in existence today. The most widely used isotope studied with AMS is 14C. Besides radiocarbon dating this isotope is used in climate studies, biomedicine applications and many other fields. More than 100,000 14C samples are measured per year. Other isotopes studied include 10Be, 26Al, 36Cl, 41Ca, 59Ni, 129I, U, and Pu. Although these measurements are important, the number of samples of these other isotopes measured each year is estimated to be less than 10% of the number of 14C samples. Copyright 2008 Wiley Periodicals, Inc.

  19. Fast neutron spectrometry and dosimetry

    International Nuclear Information System (INIS)

    Blaize, S.; Ailloud, J.; Mariani, J.; Millot, J.P.

    1958-01-01

    We have studied fast neutron spectrometry and dosimetry through the recoil protons they produce in hydrogenated samples. In spectrometric, we used nuclear emulsions, in dosimetric, we used polyethylene coated with zinc sulphide and placed before a photomultiplier. (author) [fr

  20. Mass Spectrometry of Halopyrazolium Salts

    DEFF Research Database (Denmark)

    Larsen, Elfinn; Egsgaard, Helge; Pande, U. C.

    1983-01-01

    Eleven halogen substituted 1-methyl-2-phenylpyrazolium bromides or chlorides were investigated by field desorption, field ionization, and electron impact mass spectrometry. Dealkylation was found to be the predominant thermal decomposition. An exchange between covalent and ionic halogen prior...

  1. Study on the natural radioactivity from the region of Presidente Figueiredo (AM), Brazil, using gamma spectrometry

    International Nuclear Information System (INIS)

    Da Silva, Jose Ribamar Silveira

    1999-01-01

    A gamma spectrometry profile was carried out along BR174 highway, that crosses some lithostratigraphic units of the North portion of the Sedimentary Basin of Amazon. Measurements in situ were realized in 116 points, 1 km apart, using a GAD-6 gamma-spectrometer and samples of rocks and soils were collected in geologically representative points, for gamma measurements using a shielded detector of NaI(Tl) available in the Nuclear Geophysics Laboratory of IAG/USP. The criterion used for evaluating the reliability degree of the concentration values of eU (ppm), eTh (ppm) and %K was to establish mathematically detection limits, for all measurement points. Every these points had been located using GPS with accuracy of 50 m to become possible a future detailed study. The purpose of matching portable gamma spectrometer and laboratory determinations was to compare the 2 techniques, using the criterion of detectability limits, and to verify the influence of 222 Rn atmospheric radioactive gas in field measurements. In the case of portable detector, it allows fast measurements and the sensor 'sees' a big volume of material (rock, soil...), that makes it more representative. In some situations where atmospheric phenomena of thermal inversion occurs, measurement can be affected by the 222 Rn cosmic background. Presence of radon daughter elements, associated with aerosols, in this tropical environment (high values of temperature and humidity), where the speed of the wind that could exhaust this gas is practically zero. It is observed that the values of concentration in the some points, got with these 2 techniques, have the same trend, and the stretches where peaks of concentration of K also occur and U and Th are associated with the presence of granite out corps, great boulders, and clay soils from weathering of these rocks. (author)

  2. Radiological Mapping of the Alkaline Intrusive Complex of Jombo, South Coastal Kenya by In-Situ Gamma-Ray Spectrometry

    Science.gov (United States)

    Kaniu, Ian; Darby, Iain G.; Kalambuka Angeyo, Hudson

    2016-04-01

    Carbonatites and alkaline intrusive complexes are rich in a variety of mineral deposits such as rare earth elements (REEs), including Nb, Zr and Mn. These are often associated with U and Th bearing minerals, including monazite, samarskite and pyrochlore. Mining waste resulting from mineral processing activities can be highly radioactive and therefore poses a risk to human health and environment. The Jombo complex located in Kenya's south coastal region is potentially one of the richest sources of Nb and REEs in the world. It consists of the main intrusion at Jombo hill, three associated satellite intrusions at Mrima, Kiruku and Nguluku hills, and several dykes. The complex is highly heterogeneous with regard to its geological formation as it is characterized by alkaline igneous rocks and carbonatites which also influence its radio-ecological dynamics. In-situ gamma spectrometry offers a low-cost, rapid and spatially representative radioactivity estimate across a range of landscapes compared to conventional radiometric techniques. In this work, a wide ranging radiological survey was conducted in the Jombo complex as follow up on previous studies[1,2], to determine radiation exposure levels and source distributions, and perform radiological risk assessments. The in-situ measurements were carried out using a 2.0 l NaI(Tl) PGIS-2 portable detector from Pico Envirotec Inc integrated with GPS, deployed for ground (back-pack) and vehicular gamma-ray spectrometry. Preliminary results of radiological distribution and mapping will be presented. [1] Patel, J. P. (1991). Discovery and Innovation, 3(3): 31-35. [2] Kebwaro, J. M. et. al. (2011). J. Phys. Sci., 6(13): 3105-3110.

  3. Flame emission, atomic absorption and fluorescence spectrometry

    International Nuclear Information System (INIS)

    Horlick, G.

    1980-01-01

    Six hundred and thirty references are cited in this review. The information in the review is divided into 12 major areas: books, reviews, and bibliographies; fundamental studies in flames; developments in instrumentation; measurement techniques and procedure; flame emission spectrometry; flame atomic absorption spectrometry; flame molecular absorption spectrometry; electrothermal atomization atomic absorption spectroscopy; hydride generation techniques; graphite furnace atomic emission spectrometry; atomic fluorescence spectrometry; and analytical comparisons

  4. Ultra-sensitive radionuclide spectrometry. Radiometrics and mass spectrometry synergy

    International Nuclear Information System (INIS)

    Povinec, P.P.

    2005-01-01

    Recent developments in radiometrics and mass spectrometry techniques for ultra-sensitive analysis of radionuclides in the marine environment are reviewed. In the radiometrics sector the dominant development has been the utilization of large HPGe detectors in underground laboratories with anti-cosmic or anti-Compton shielding for the analysis of short and medium-lived radionuclides in the environment. In the mass spectrometry sector, applications of inductively coupled plasma mass spectrometry (ICP-MS) and accelerator mass spectrometry (AMS) for the analysis of long-lived radionuclides in the environment are the most important recent achievements. The recent developments do not only considerably decrease the detection limits for several radionuclides (up to several orders of magnitude), but they also enable to decrease sample volumes so that sampling, e.g., of the water column can be much easier and more effective. A comparison of radiometrics and mass spectrometry results for the analysis of radionuclides in the marine environment shows a reasonable agreement - within quoted uncertainties, for wide range of activities and different sample matrices analyzed. (author)

  5. Cluster secondary ion mass spectrometry microscope mode mass spectrometry imaging.

    Science.gov (United States)

    Kiss, András; Smith, Donald F; Jungmann, Julia H; Heeren, Ron M A

    2013-12-30

    Microscope mode imaging for secondary ion mass spectrometry is a technique with the promise of simultaneous high spatial resolution and high-speed imaging of biomolecules from complex surfaces. Technological developments such as new position-sensitive detectors, in combination with polyatomic primary ion sources, are required to exploit the full potential of microscope mode mass spectrometry imaging, i.e. to efficiently push the limits of ultra-high spatial resolution, sample throughput and sensitivity. In this work, a C60 primary source was combined with a commercial mass microscope for microscope mode secondary ion mass spectrometry imaging. The detector setup is a pixelated detector from the Medipix/Timepix family with high-voltage post-acceleration capabilities. The system's mass spectral and imaging performance is tested with various benchmark samples and thin tissue sections. The high secondary ion yield (with respect to 'traditional' monatomic primary ion sources) of the C60 primary ion source and the increased sensitivity of the high voltage detector setup improve microscope mode secondary ion mass spectrometry imaging. The analysis time and the signal-to-noise ratio are improved compared with other microscope mode imaging systems, all at high spatial resolution. We have demonstrated the unique capabilities of a C60 ion microscope with a Timepix detector for high spatial resolution microscope mode secondary ion mass spectrometry imaging. Copyright © 2013 John Wiley & Sons, Ltd.

  6. Detection limit of 238U by gamma spectrometry

    International Nuclear Information System (INIS)

    Tartaglione, A.; Blostein, J.; Mayer, R

    2004-01-01

    The detection limit of 238 U was determined by gamma spectra measurements of a depleted uranium sample using four NaI(Tl) scintillators in a compact arrangement.The sample was shielded with 5 and 10 cm of lead.Two different methods for data processing were used and compared.It was established that an appropriate array of 40 detectors could establish the presence of 220 g of this material in only 5 minutes [es

  7. Symposium on accelerator mass spectrometry

    International Nuclear Information System (INIS)

    1981-01-01

    The area of accelerator mass spectrometry has expanded considerably over the past few years and established itself as an independent and interdisciplinary research field. Three years have passed since the first meeting was held at Rochester. A Symposium on Accelerator Mass Spectrometry was held at Argonne on May 11-13, 1981. In attendance were 96 scientists of whom 26 were from outside the United States. The present proceedings document the program and excitement of the field. Papers are arranged according to the original program. A few papers not presented at the meeting have been added to complete the information on the status of accelerator mass spectrometry. Individual papers were prepared separately for the data base

  8. Symposium on accelerator mass spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    None

    1981-01-01

    The area of accelerator mass spectrometry has expanded considerably over the past few years and established itself as an independent and interdisciplinary research field. Three years have passed since the first meeting was held at Rochester. A Symposium on Accelerator Mass Spectrometry was held at Argonne on May 11-13, 1981. In attendance were 96 scientists of whom 26 were from outside the United States. The present proceedings document the program and excitement of the field. Papers are arranged according to the original program. A few papers not presented at the meeting have been added to complete the information on the status of accelerator mass spectrometry. Individual papers were prepared separately for the data base.

  9. New trends in nuclear spectrometry

    International Nuclear Information System (INIS)

    Westmeier, W.; Siemon, K.

    2013-01-01

    An overview on the status and function of current spectrometry hardware, of detectors having energy-dispersive (spectrometric) properties as well as of the latest developments in quantitative spectrometry software is presented. Making extensive use of modern computing power, new strategies in high-precision spectrum analysis have been developed which enhance the quality of results and also open new fields of spectrometric applications. Three principles have been newly introduced to spectrum analysis software: -use no approximations in modelling (Physics, no numerology) -apply all available models to find a solution (Fuzzy Logic) -repeat complete analyses for iterative improvement (Learn from results). -- Highlights: ► We present an overview of MCA hardware and detectors for nuclear spectrometry. ► Physics-oriented descriptions, Fuzzy Logic and multiple repetitive analyses lead to improved results in spectrum analysis. ► New strategies allow the successful deconvolution of spectra that could not be analysed before

  10. Mass spectrometry. [in organic chemistry

    Science.gov (United States)

    Burlingame, A. L.; Shackleton, C. H. L.; Howe, I.; Chizhov, O. S.

    1978-01-01

    A review of mass spectrometry in organic chemistry is given, dealing with advances in instrumentation and computer techniques, selected topics in gas-phase ion chemistry, and applications in such fields as biomedicine, natural-product studies, and environmental pollution analysis. Innovative techniques and instrumentation are discussed, along with chromatographic-mass spectrometric on-line computer techniques, mass spectral interpretation and management techniques, and such topics in gas-phase ion chemistry as electron-impact ionization and decomposition, photoionization, field ionization and desorption, high-pressure mass spectrometry, ion cyclotron resonance, and isomerization reactions of organic ions. Applications of mass spectrometry are examined with respect to bio-oligomers and their constituents, biomedically important substances, microbiology, environmental organic analysis, and organic geochemistry.

  11. Mass spectrometry for biomarker development

    Energy Technology Data Exchange (ETDEWEB)

    Wu, Chaochao; Liu, Tao; Baker, Erin Shammel; Rodland, Karin D.; Smith, Richard D.

    2015-06-19

    Biomarkers potentially play a crucial role in early disease diagnosis, prognosis and targeted therapy. In the past decade, mass spectrometry based proteomics has become increasingly important in biomarker development due to large advances in technology and associated methods. This chapter mainly focuses on the application of broad (e.g. shotgun) proteomics in biomarker discovery and the utility of targeted proteomics in biomarker verification and validation. A range of mass spectrometry methodologies are discussed emphasizing their efficacy in the different stages in biomarker development, with a particular emphasis on blood biomarker development.

  12. Coincidence gamma-ray spectrometry

    DEFF Research Database (Denmark)

    Markovic, Nikola; Roos, Per; Nielsen, Sven Poul

    2017-01-01

    Gamma-ray spectrometry with high-purity germanium (HPGe) detectors is often the technique of choice in an environmental radioactivity laboratory. When measuring environmental samples associated activities are usually low so an important parameter that describes the performance of the spectrometer...... for a nuclide of interest is the minimum detectable activity (MDA). There are many ways for lowering the MDAs in gamma spectrometry. Recently, developments of fast and compact digital acquisition systems have led to growing number of multiple HPGe detector spectrometers. In these applications all detected...

  13. Some analytical aspects of the Moessbauer spectrometry

    International Nuclear Information System (INIS)

    Meisel, W.

    1975-01-01

    Analytical applications of Moessbauer spectrometry are reviewed. Various methods of analysis (qualitative, semiquantitative and quantitative) using the Moessbauer effect are dealt with. Sensitivity and accuracy of Moessbauer spectrometry in analytical applications are discussed. (Z.S.)

  14. X-ray fluorescence spectrometry

    International Nuclear Information System (INIS)

    Vries, J.L. de.

    1976-01-01

    The seventh edition of Philips' Review of Literature on x-ray fluorescence spectrometry starts with a list of conference proceedings on the subject, organised by the Philips organisation at regular intervals in various European countries. It is followed by a list of bulletins. The bibliography is subdivided according to spectra, equipment, applications and absorption analysis

  15. Mass spectrometry in epigenetic research

    DEFF Research Database (Denmark)

    Beck, Hans Christian

    2010-01-01

    cancers has gained tremendous interest in recent years, and many of these inhibitors are currently undergoing clinical trials. Despite intense research, however, the exact molecular mechanisms of action of these molecules remain, to a wide extent, unclear. The recent application of mass spectrometry...

  16. X-ray fluorescence spectrometry

    International Nuclear Information System (INIS)

    Ray, N.B.

    1977-01-01

    The principle, instrument and procedure of X-ray fluorescence spectrometry are described. It is a rapid, simple and sensitive method for the trace analysis of elements from sodium to uranium in powder, liquid or metal samples. (M.G.B.)

  17. Mass spectrometry of large molecules

    International Nuclear Information System (INIS)

    Facchetti, S.

    1985-01-01

    The lectures in this volume were given at a course on mass spectrometry of large molecules, organized within the framework of the Training and Education programme of the Joint Research Centre of the European Communities. Although first presented in 1983, most of the lectures have since been updated by their authors. (orig.)

  18. Gamma and X 93 spectrometry

    International Nuclear Information System (INIS)

    1994-05-01

    The Meetings of Gamma and X 93 Spectrometry were held on 12-14 October 1993. The symposium was organized into six sessions: Instrumentation development, Nuclear matter measurement, Method and calibration, Medical applications, Environment survey (radioactive traces measurement), other applications (spent fuels analysis, various techniques). Separate abstracts were prepared for all the papers in this volume. (TEC)

  19. Mass spectrometry with particle accelerator

    International Nuclear Information System (INIS)

    Anon.

    1983-01-01

    The heavy ion accelerator use is renewing the ultrasensitive mass spectrometry in extending the detection limits. These new devices allow the measurement of rare isotope ratio, as 10 Be, 14 C, 26 Al, 36 Cl or 41 Ca, from the earth natural reservoirs [fr

  20. Eleventh ISMAS workshop on mass spectrometry

    International Nuclear Information System (INIS)

    Aggarwal, S.K.; Jaison, P.G.

    2004-10-01

    This volume deals with the latest developments in this field, exposing the innumerable applications of mass spectrometry. The topics covered include basic fundamentals of mass spectrometry, qualitative and quantitative aspects and data interpretation, maintenance of mass spectrometers, selection of a mass spectrometer, its applications in various branches of science as well as recent advances in mass spectrometry. Emphasis is also laid on the practical aspects of mass spectrometry. Papers relevant to INIS are indexed separately

  1. Ninth ISMAS workshop on mass spectrometry

    International Nuclear Information System (INIS)

    Aggarwal, S.K.

    2000-12-01

    Mass spectrometry has wide-ranging applications in such diverse areas as nuclear industry, agriculture, drugs, environment, petroleum and lentils. There is an urgent need to absorb and assimilate state-of-the-art technological developments in the field. Emerging trends in atomic mass spectrometry, advances in organic mass spectrometry, qualitative and quantitative analyses by mass spectrometry and mass spectrometry in oceanography are some of the areas that need to be expeditiously examined and are covered in this volume. Papers relevant to INIS are indexed separately

  2. Alpha spectrometry and the secondary ion mass spectrometry of thorium

    International Nuclear Information System (INIS)

    Strisovska, J.; Kuruc, J.; Galanda, D.; Matel, L.; Aranyosiova, M.; Velic, D.

    2009-01-01

    The main objective of this master thesis was preparation of samples with thorium content on the steel discs by electrodeposition for determination of natural thorium isotope by alpha spectrometry and the secondary ion mass spectrometry and finding out their possible linear correlation between these methods. The samples with electrolytically excluded isotope of 232 Th were prepared by electrodeposition from solution Th(NO 3 ) 4 ·12 H2 O on steel discs in electrodeposition cell with use of solutions Na 2 SO 4 , NaHSO 4 , KOH and (NH 4 ) 2 (C 2 O 4 ) by electric current 0.75 A. Discs were measured by alpha spectrometer. Activity was calculated from the registered impulses for 232 Th and surface's weight. After alpha spectrometry measurements discs were analyzed by TOF-SIMS IV which is installed in the International Laser Centre in Bratislava. Intensities of isotope of 232 Th and ions of ThO + , ThOH + , ThO 2 H + , Th 2 O 4 H + , ThO 2 - , ThO 3 H - , ThH 3 O 3 - and ThN 2 O 5 H - were identified. The linear correlation is between surface's weights of Th and intensities of ions of Th + from SIMS, however the correlation coefficient has relatively low value. We found out with SIMS method that oxidized and hydride forms of thorium are significantly represented in samples with electroplated thorium. (authors)

  3. Mass spectrometry and tandem mass spectrometry of citrus limonoids.

    Science.gov (United States)

    Tian, Qingguo; Schwartz, Steven J

    2003-10-15

    Methods for atmospheric pressure chemical ionization tandem mass spectrometry (APCI-MS/MS) of citrus limonoid aglycones and electrospray ionization tandem mass spectrometry (ESI-MS/MS) of limonoid glucosides are reported. The fragmentation patterns of four citrus limonoid aglycones (limonin, nomilin, obacunone, and deacetylnomilin) and six limonoid glucosides, that is, limonin 17-beta-D-glucopyranoside (LG), nomilin 17-beta-D-glucopyranoside (NG), nomilinic acid 17-beta-D-glucopyranoside (NAG), deacetyl nomilinic acid 17-beta-D-glucopyranoside (DNAG), obacunone 17-beta-D-glucopyranoside (OG), and obacunoic acid 17-beta-D-glucopyranoside (OAG) were investigated using a quadruple mass spectrometer in low-energy collisionally activated dissociation (CAD). The four limonoid aglycones and four limonoid glucosides (LG, OG, NAG, and DNAG) were purified from citrus seeds; the other two limonoid glucosides (NG and OAG) were tentatively identified in the crude extract of grapefruit seeds by ESI mass spectrometry in both positive and negative ion analysis. Ammonium hydroxide or acetic acid was added to the mobile phase to facilitate ionization. During positive ion APCI analysis of limonoid aglycones, protonated molecular ion, [M + H]+, or adduct ion, [M + NH3 + H]-, was formed as base peaks when ammonium hydroxide was added to the mobile phase. Molecular anions or adduct ions with acetic acid ([M + HOAc - H] and [M + HOAc]-) or a deprotonated molecular ion were produced during negative ion APCI analysis of limonoid aglycones, depending on the mobile-phase modifier used. Positive ion ESI-MS of limonoid glucosides produced adduct ions of [M + H + NH3]+, [M + Na]+, and [M + K]+ when ammonium hydroxide was added to the mobile phase. After collisionally activated dissociation (CAD) of the limonoid aglycone molecular ions in negative ion APCI analysis, fragment ions indicated structural information of the precursor ions, showing the presence of methyl, carboxyl, and oxygenated ring

  4. Imaging Mass Spectrometry in Neuroscience

    Science.gov (United States)

    2013-01-01

    Imaging mass spectrometry is an emerging technique of great potential for investigating the chemical architecture in biological matrices. Although the potential for studying neurobiological systems is evident, the relevance of the technique for application in neuroscience is still in its infancy. In the present Review, a principal overview of the different approaches, including matrix assisted laser desorption ionization and secondary ion mass spectrometry, is provided with particular focus on their strengths and limitations for studying different neurochemical species in situ and in vitro. The potential of the various approaches is discussed based on both fundamental and biomedical neuroscience research. This Review aims to serve as a general guide to familiarize the neuroscience community and other biomedical researchers with the technique, highlighting its great potential and suitability for comprehensive and specific chemical imaging. PMID:23530951

  5. Automatic gamma spectrometry analytical apparatus

    International Nuclear Information System (INIS)

    Lamargot, J.-P.; Wanin, Maurice.

    1980-01-01

    This invention falls within the area of quantitative or semi-quantitative analysis by gamma spectrometry and particularly refers to a device for bringing the samples into the counting position. The purpose of this invention is precisely to provide an automatic apparatus specifically adapted to the analysis of hard gamma radiations. To this effect, the invention relates to a gamma spectrometry analytical device comprising a lead containment, a detector of which the sensitive part is located inside the containment and additionally comprising a transfer system for bringing the analyzed samples in succession to a counting position inside the containment above the detector. A feed compartment enables the samples to be brought in turn one by one on to the transfer system through a duct connecting the compartment to the transfer system. Sequential systems for the coordinated forward feed of the samples in the compartment and the transfer system complete this device [fr

  6. Mass Spectrometry Instrumentation in Proteomics

    DEFF Research Database (Denmark)

    Sprenger, Richard Remko; Roepstorff, Peter

    2012-01-01

    Mass spectrometry has evolved into a crucial technology for the field of proteomics, enabling the comprehensive study of proteins in biological systems. Innovative developments have yielded flexible and versatile mass spectrometric tools, including quadrupole time-of-flight, linear ion trap......, Orbitrap and ion mobility instruments. Together they offer various and complementary capabilities in terms of ionization, sensitivity, speed, resolution, mass accuracy, dynamic range and methods of fragmentation. Mass spectrometers can acquire qualitative and quantitative information on a large scale...

  7. Mass Spectrometry Applications for Toxicology

    OpenAIRE

    Mbughuni, Michael M.; Jannetto, Paul J.; Langman, Loralie J.

    2016-01-01

    Toxicology is a multidisciplinary study of poisons, aimed to correlate the quantitative and qualitative relationships between poisons and their physiological and behavioural effects in living systems. Other key aspects of toxicology focus on elucidation of the mechanisms of action of poisons and development of remedies and treatment plans for associated toxic effects. In these endeavours, Mass spectrometry (MS) has become a powerful analytical technique with a wide range of application used i...

  8. The history of radiation spectrometry

    International Nuclear Information System (INIS)

    Mori, Kunishiro

    2007-01-01

    Recently combination of charge sensitive amplifier, pulse shape amplifier and multi-channel PHA (MCA) is regarded as standard configuration of radiation spectrometry. PHA history shows various kinds of MCA devices before we have obtained original digital ADC technology based MCA in 1960s. Those MCAs include interesting ones such as photographic type, which still keep fresh ideas even today. Room temperature preamplifiers are classified to low, medium range, and large capacitance (over 10000pF) detectors keeping ultra low noise. (author)

  9. Instrumentation for mass spectrometry: 1997

    Energy Technology Data Exchange (ETDEWEB)

    McLuckey, S.A.

    1997-08-01

    All mass spectrometry experiments involve the manipulation of material, an interface with the mass spectrometer, ionization, ion manipulation/analysis, detection and data collection/reduction. Each of these elements involve instrumentation. The wide range of species now amenable to mass spectrometry and the diverse areas of physical science in which it plays a role have led to a seemingly unlimited array of instrumental combinations. However, only a limited number of mass analyzers, and their combinations, dominate. The dominant analyzers include time-of-flight, Fourier transform ion cyclotron resonance, the Paul trap, the mass filter, and the sector mass spectrometer. Why there are so few (or so many, depending upon one`s point of view) can be understood upon consideration of a set of mass analyzer figures of merit. These include mass resolution, mass accuracy, mass range, dynamic range, abundance sensitivity, precision, efficiency, speed, MS{sup n} capability, compatibility with the ionizer, cost, and size. The most appropriate form of mass spectrometry is determined by the priorities of the particular measurement placed on the various mass analyzer characteristics and the relative strengths of the analyzers in meeting the requirements. Each of the analyzer types has a unique set of figures of merit that makes it optimally suited for particular applications. This paper discusses these figures of merit, provides data illustrating recent developments for each analyzer type, and gives the figures of merit of each type of analyzer as they stand in 1997. 101 refs., 24 figs.

  10. Urban gamma spectrometry. Report 2

    Energy Technology Data Exchange (ETDEWEB)

    Aage, H.K. (Technical Univ. of Denmark, Kgs. Lyngby (Denmark)); Kuukankorpi, S.; Moring, M.; Smolander, P.; Toivonen, H. (Radiation and Nuclear Safety Authority, Helsinki (Finland))

    2009-06-15

    Urban gamma spectrometry has been given only minor attention with the focus being on rural gamma spectrometry. However, in recent years the Nordic emergency management authorities have turned focus towards border control and lost or stolen sources. Gamma spectra measured in urban areas are characterized by a wide variety of spectrum shapes and very fast changes in environmental background. In 2004 a Danish CGS (Carborne Gamma Spectrometry) survey took place in Copenhagen. It was found that gamma spectrometry in urban areas is far more complicated to interpret than had previously been thought and a new method 'Fitting with Spectral Components', FSC, based on NASVD, was tested with some success. In Finland, a database 'LINSSI' has been developed for spectral data management. In CGS search mode a 'peak hypothesis test' is applied to the measured spectra. This system was tested during the Helsinki 2005 Athletics World Championship and it provides fast and reliable automated alarms for intermediate and high level signals. In Sweden mobile detector systems are used for border controls and problems are encountered when making measurement in harbour, container areas. The methods for handling data and for interpretation of urban gamma spectrometry measurements were compared and tested on the same data sets from Copenhagen and Helsinki. Software tools were developed for converting data between the Finnish LINSSI database and the binary file formats used in Denmark and Sweden. The Processing methods used at DTU and STUK have different goals. The ASSS and FSC methods are designed to optimize the overall detection capability of the system, while sacrificing speed, usability and to a certain level robustness. These methods cannot always be used for real time analysis. The Peak Significance method is designed to give robust alarms in real time, while sacrificing some of the detection capability. Thus these methods are not interchangeable, but rather

  11. Urban gamma spectrometry. Report 2

    International Nuclear Information System (INIS)

    Aage, H.K.; Kuukankorpi, S.; Moring, M.; Smolander, P.; Toivonen, H.

    2009-06-01

    Urban gamma spectrometry has been given only minor attention with the focus being on rural gamma spectrometry. However, in recent years the Nordic emergency management authorities have turned focus towards border control and lost or stolen sources. Gamma spectra measured in urban areas are characterized by a wide variety of spectrum shapes and very fast changes in environmental background. In 2004 a Danish CGS (Carborne Gamma Spectrometry) survey took place in Copenhagen. It was found that gamma spectrometry in urban areas is far more complicated to interpret than had previously been thought and a new method 'Fitting with Spectral Components', FSC, based on NASVD, was tested with some success. In Finland, a database 'LINSSI' has been developed for spectral data management. In CGS search mode a 'peak hypothesis test' is applied to the measured spectra. This system was tested during the Helsinki 2005 Athletics World Championship and it provides fast and reliable automated alarms for intermediate and high level signals. In Sweden mobile detector systems are used for border controls and problems are encountered when making measurement in harbour, container areas. The methods for handling data and for interpretation of urban gamma spectrometry measurements were compared and tested on the same data sets from Copenhagen and Helsinki. Software tools were developed for converting data between the Finnish LINSSI database and the binary file formats used in Denmark and Sweden. The Processing methods used at DTU and STUK have different goals. The ASSS and FSC methods are designed to optimize the overall detection capability of the system, while sacrificing speed, usability and to a certain level robustness. These methods cannot always be used for real time analysis. The Peak Significance method is designed to give robust alarms in real time, while sacrificing some of the detection capability. Thus these methods are not interchangeable, but rather complementary. An ideal system

  12. Applied gamma-ray spectrometry

    CERN Document Server

    Dams, R; Crouthamel, Carl E

    1970-01-01

    Applied Gamma-Ray Spectrometry covers real life application of the gamma-ray and the devices used in their experimental studies. This book is organized into 9 chapters, and starts with discussions of the various decay processes, the possible interaction mechanisms of gamma radiation with matter, and the intrinsic and extrinsic variables, which affect the observed gamma-ray and X-ray spectra. The subsequent chapters deal with the properties and fabrication of scintillation detectors, semiconductor detectors, and proportional gas counters. These chapters present some of the most widely utilized

  13. Mass spectrometry. [review of techniques

    Science.gov (United States)

    Burlingame, A. L.; Kimble, B. J.; Derrick, P. J.

    1976-01-01

    Advances in mass spectrometry (MS) and its applications over the past decade are reviewed in depth, with annotated literature references. New instrumentation and techniques surveyed include: modulated-beam MS, chromatographic MS on-line computer techniques, digital computer-compatible quadrupole MS, selected ion monitoring (mass fragmentography), and computer-aided management of MS data and interpretation. Areas of application surveyed include: organic MS and electron impact MS, field ionization kinetics, appearance potentials, translational energy release, studies of metastable species, photoionization, calculations of molecular orbitals, chemical kinetics, field desorption MS, high pressure MS, ion cyclotron resonance, biochemistry, medical/clinical chemistry, pharmacology, and environmental chemistry and pollution studies.

  14. Deuterium measurement by emission spectrometry

    International Nuclear Information System (INIS)

    Niemann, E.G.; Heilig, K.; Dumke, I.

    1978-01-01

    The method makes it possible to determine the relative deuterium content of enriched water samples. For this, the relative intensities of the Hα and Dα lines are measured which are emitted by a high-frequency discharge in water vapour. Although the method is not as exact as mass spectrometry, it has the following advantages: - Easy sample preparation (no reduction necessary); - samples of highly different enrichment can be measured one after the other without the danger of memory effects; - much lower apparatus and cost expenditure. The necessary sample size is about the same in both methods. (orig.) [de

  15. Functional genomics by mass spectrometry

    DEFF Research Database (Denmark)

    Andersen, Jens S.; Mann, M

    2000-01-01

    Systematic analysis of the function of genes can take place at the oligonucleotide or protein level. The latter has the advantage of being closest to function, since it is proteins that perform most of the reactions necessary for the cell. For most protein based ('proteomic') approaches to gene f...... numbers of intact proteins by mass spectrometry directly. Examples from this laboratory illustrate biological problem solving by modern mass spectrometric techniques. These include the analysis of the structure and function of the nucleolus and the analysis of signaling complexes....

  16. Principle of accelerator mass spectrometry

    International Nuclear Information System (INIS)

    Matsuzaki, Hiroyuki

    2007-01-01

    The principle of accelerator mass spectrometry (AMS) is described mainly on technical aspects: hardware construction of AMS, measurement of isotope ratio, sensitivity of measurement (measuring limit), measuring accuracy, and application of data. The content may be summarized as follows: rare isotope (often long-lived radioactive isotope) can be detected by various use of the ion energy obtained by the acceleration of ions, a measurable isotope ratio is one of rare isotope to abundant isotopes, and a measured value of isotope ratio is uncertainty to true one. Such a fact must be kept in mind on the use of AMS data to application research. (M.H.)

  17. Role of Mass Spectrometry in Clinical Endocrinology.

    Science.gov (United States)

    Ketha, Siva S; Singh, Ravinder J; Ketha, Hemamalini

    2017-09-01

    The advent of mass spectrometry into the clinical laboratory has led to an improvement in clinical management of several endocrine diseases. Liquid chromatography tandem mass spectrometry found some of its first clinical applications in the diagnosis of inborn errors of metabolism, in quantitative steroid analysis, and in drug analysis laboratories. Mass spectrometry assays offer analytical sensitivity and specificity that is superior to immunoassays for many analytes. This article highlights several areas of clinical endocrinology that have witnessed the use of liquid chromatography tandem mass spectrometry to improve clinical outcomes. Copyright © 2017 Elsevier Inc. All rights reserved.

  18. Twenty years of experience in applying gamma spectrometry for NDT

    International Nuclear Information System (INIS)

    Meenakshisundaram, V.; Raghunath, V.M.

    1996-01-01

    A NDT technique using NaI(Tl) detector and Single Channel Analyser (SCA) based gamma ray spectrometer was developed to check the shielding integrity of lead poured vessels, for as low a specification as 2% tolerance. The method in detail, its advantages, and some of the interesting findings are described. This paper also highlights other possible in-situ applications like i) identifying cracks propagating in end shield of a Pressurised Heavy Water Reactor (PHWR) in the presence of high radiation field and ii) level estimation for liquids such as Na and NaK used in fast reactor storage tanks. (author)

  19. Quantitative mass spectrometry: an overview

    Science.gov (United States)

    Urban, Pawel L.

    2016-10-01

    Mass spectrometry (MS) is a mainstream chemical analysis technique in the twenty-first century. It has contributed to numerous discoveries in chemistry, physics and biochemistry. Hundreds of research laboratories scattered all over the world use MS every day to investigate fundamental phenomena on the molecular level. MS is also widely used by industry-especially in drug discovery, quality control and food safety protocols. In some cases, mass spectrometers are indispensable and irreplaceable by any other metrological tools. The uniqueness of MS is due to the fact that it enables direct identification of molecules based on the mass-to-charge ratios as well as fragmentation patterns. Thus, for several decades now, MS has been used in qualitative chemical analysis. To address the pressing need for quantitative molecular measurements, a number of laboratories focused on technological and methodological improvements that could render MS a fully quantitative metrological platform. In this theme issue, the experts working for some of those laboratories share their knowledge and enthusiasm about quantitative MS. I hope this theme issue will benefit readers, and foster fundamental and applied research based on quantitative MS measurements. This article is part of the themed issue 'Quantitative mass spectrometry'.

  20. Mass Spectrometry Applications for Toxicology.

    Science.gov (United States)

    Mbughuni, Michael M; Jannetto, Paul J; Langman, Loralie J

    2016-12-01

    Toxicology is a multidisciplinary study of poisons, aimed to correlate the quantitative and qualitative relationships between poisons and their physiological and behavioural effects in living systems. Other key aspects of toxicology focus on elucidation of the mechanisms of action of poisons and development of remedies and treatment plans for associated toxic effects. In these endeavours, Mass spectrometry (MS) has become a powerful analytical technique with a wide range of application used in the Toxicological analysis of drugs, poisons, and metabolites of both. To date, MS applications have permeated all fields of toxicology which include; environmental, clinical, and forensic toxicology. While many different analytical applications are used in these fields, MS and its hyphenated applications such as; gas chromatography MS (GC-MS), liquid chromatography MS (LC-MS), inductively coupled plasma ionization MS (ICP-MS), tandem mass spectrometry (MS/MS and MS n ) have emerged as powerful tools used in toxicology laboratories. This review will focus on these hyphenated MS technologies and their applications for toxicology.

  1. Mass Spectrometry Applications for Toxicology

    Science.gov (United States)

    Mbughuni, Michael M.; Jannetto, Paul J.

    2016-01-01

    Toxicology is a multidisciplinary study of poisons, aimed to correlate the quantitative and qualitative relationships between poisons and their physiological and behavioural effects in living systems. Other key aspects of toxicology focus on elucidation of the mechanisms of action of poisons and development of remedies and treatment plans for associated toxic effects. In these endeavours, Mass spectrometry (MS) has become a powerful analytical technique with a wide range of application used in the Toxicological analysis of drugs, poisons, and metabolites of both. To date, MS applications have permeated all fields of toxicology which include; environmental, clinical, and forensic toxicology. While many different analytical applications are used in these fields, MS and its hyphenated applications such as; gas chromatography MS (GC-MS), liquid chromatography MS (LC-MS), inductively coupled plasma ionization MS (ICP-MS), tandem mass spectrometry (MS/MS and MSn) have emerged as powerful tools used in toxicology laboratories. This review will focus on these hyphenated MS technologies and their applications for toxicology. PMID:28149262

  2. Mass spectrometry-assisted protease substrate screening

    DEFF Research Database (Denmark)

    Schlüter, Hartmut; Rykl, Jana; Thiemann, Joachim

    2007-01-01

    -phase chromatography they are analyzed by tandem mass spectrometry and the substrates identified by database searching. The proof of principle in this study is demonstrated by incubating immobilized human plasma proteins with thrombin and by identifying by tandem mass spectrometry the fibrinopeptides, released...

  3. Inorganic mass spectrometry of solid samples

    International Nuclear Information System (INIS)

    Adams, F.; Vertes, A.

    1990-01-01

    In this review some recent developments in the field of inorganic mass spectrometry of solids are described with special emphasis on the actual state of understanding of the ionization processes. It concentrates on the common characteristics of methods such as spark source-, laser-, secondary ion-, inductively coupled plasma- and glow discharge mass spectrometry. (orig.)

  4. Surface analysis by imaging mass spectrometry

    Czech Academy of Sciences Publication Activity Database

    Vidová, Veronika; Volný, Michael; Lemr, Karel; Havlíček, Vladimír

    2009-01-01

    Roč. 74, 7-8 (2009), s. 1101-1116 ISSN 0010-0765 Institutional research plan: CEZ:AV0Z50200510 Keywords : secondary ion mass spectrometry * matrix assisted laser desorption ionization * mass spectrometry Subject RIV: CB - Analytical Chemistry, Separation Impact factor: 0.856, year: 2009

  5. Introduction to mass spectrometry-based proteomics

    DEFF Research Database (Denmark)

    Matthiesen, R.; Bunkenborg, J.

    2013-01-01

    Mass spectrometry has been widely applied to study biomolecules and one rapidly developing field is the global analysis of proteins, proteomics. Understanding and handling mass spectrometry data is a multifaceted task that requires many decisions to be made to get the most comprehensive informati...

  6. Gamma spectrometry of infinite 4Π geometry

    International Nuclear Information System (INIS)

    Nordemann, D.J.R.

    1987-07-01

    Owing to the weak absorption og gamma radiation by matter, gamma-ray spectrometry may be applied to samples of great volume. A very interesting case is that of the gamma-ray spectrometry applied with 4Π geometry around the detector on a sample assumed to be of infinite extension. The determination of suitable efficiencies allows this method to be quantitative. (author) [pt

  7. Reliability of graphite furnace atomic absorption spectrometry as ...

    African Journals Online (AJOL)

    spectrometry as alternative method for trace analysis of ... Purpose: To evaluate the comparative efficiency of graphite furnace atomic absorption spectrometry .... Methods comparison and validation .... plasma-optical emission spectrometry.

  8. Accelerator mass spectrometry in NIPNE

    International Nuclear Information System (INIS)

    Ivascu, M; Marinescu, L.; Dima, R.; Cata-Danil, D.; Petrascu, M.; Popescu, I.; Stan-Sion, C.; Radulescu, M.; Plostinaru, D.

    1997-01-01

    The Accelerator Mass Spectrometry (AMS) is today the method capable to measure the lowest concentration of a particular nuclide in sample materials. The method has applications in environmental physics, medicine, measurements of cosmic-ray or nuclear power plant produced radionuclides in the earth's atmosphere. All over the world, more than 40 charged particles and heavy ion accelerators are performing such analyses concerning the research interest of a huge number of laboratories. The Romanian Institute of Nuclear Physics and Engineering in Bucharest has initiated a construction project for the AMS facility at the FN - Van de Graaff Tandem accelerator. This program benefits of technical and financial assistance provided by IAEA in the frame of the IAEA-TC Project ROM 8014-265C. A general lay-out of the AMS project is presented. The construction work has begun and first tests of the AMS injector will take place between July - September this year. (authors)

  9. Ion detection in mass spectrometry

    International Nuclear Information System (INIS)

    Bolbach, Gerard

    2016-03-01

    This course aims at providing some elements for a better understanding of ion detectors used in mass spectrometers, of their operations, and of their limitations. A first part addresses the functions and properties of an ideal detector, how to detect ions in gas phase, and particle detectors and ion detectors used in mass spectrometry. The second part proposes an overview of currently used detectors with respect to their operation principle: detection from the ion charge (Faraday cylinder), detection by inductive effects (FTICR, Fourier Transform Ion Cyclotron Resonance), and detection by secondary electron emission. The third part discusses the specificities of secondary electron emission. The fourth one addresses operating modes and parameters related to detectors. The sixth part proposes a prospective view on future detectors by addressing the following issues: cryo-detector, inductive effect and charge detectors, ion detection and nano materials

  10. Laser sputter neutral mass spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    King, B V; Clarke, M; Hu, H; Betz, [Newcastle Univ., NSW (Australia). Dept. of Physics

    1994-12-31

    Laser sputter neutral mass spectrometry (LSNMS) is an emerging technique for highly sensitive surface analysis. In this technique a target is bombarded with a pulsed beam of keV ions. The sputtered particles are intercepted by a high intensity pulsed laser beam above the surface and ionised with almost 100% efficiency. The photions may then be mass analysed using a quadrupole or, more commonly, using time of flight (TOF) techniques. In this method photoions are extracted from the ionisation region, accelerated to a known energy E{sub o} and strike a channelplate detector a distance `d` away. The flight time `t` of the photoions is then related to their mass by `d` {radical}m / {radical} 2E{sub o} so measurement of `t` allows mass spectra to be obtained. It is found that LSNMS is an emerging technique of great sensitivity and flexibility, useful for both applied analysis and to investigate basic sputtering processes. 4 refs., 3 figs.

  11. Laser sputter neutral mass spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    King, B.V.; Clarke, M.; Hu, H.; Betz [Newcastle Univ., NSW (Australia). Dept. of Physics

    1993-12-31

    Laser sputter neutral mass spectrometry (LSNMS) is an emerging technique for highly sensitive surface analysis. In this technique a target is bombarded with a pulsed beam of keV ions. The sputtered particles are intercepted by a high intensity pulsed laser beam above the surface and ionised with almost 100% efficiency. The photions may then be mass analysed using a quadrupole or, more commonly, using time of flight (TOF) techniques. In this method photoions are extracted from the ionisation region, accelerated to a known energy E{sub o} and strike a channelplate detector a distance `d` away. The flight time `t` of the photoions is then related to their mass by `d` {radical}m / {radical} 2E{sub o} so measurement of `t` allows mass spectra to be obtained. It is found that LSNMS is an emerging technique of great sensitivity and flexibility, useful for both applied analysis and to investigate basic sputtering processes. 4 refs., 3 figs.

  12. Mass spectrometry at the Pittsburgh conference

    International Nuclear Information System (INIS)

    Borman, S.

    1987-01-01

    Each year analytical chemists flock to the Pittsburgh Conference to learn about the latest trends in analytical instrumentation. In this Focus, a number of prominent mass spectroscopists who attended this year's meeting in Atlantic City, NJ, discuss their perceptions of current developments in the field of mass spectrometry (MS). In the June 1 issue of Analytical Chemistry, the authors coverage of the Pittsburgh Conferences continues with a follow-up article on specific developments in hyphenated mass spectrometry - primarily liquid chromatography - MS (LC/MS) and gas chromatography - infrared spectrometry MS (GC/IR/MS)

  13. A REVIEW ON MASS SPECTROMETRY DETECTORS

    OpenAIRE

    Khatri Neetu; Gupta Ankit; Taneja Ruchi; Bilandi Ajay; Beniwal Prashant

    2012-01-01

    Mass spectrometry is an analytical technique for "weighing" molecules. Obviously, this is not done with a conventional scale or balance. Instead, mass spectrometry is based upon the principle of the motion of a charged particle that is called an ion, in an electric or magnetic field. The mass to charge ratio (m/z) of the ion affects particles motion. Since the charge of an electron is known, the mass to charge ratio (m/z) is a measurement of mass of an ion. Mass spectrometry research focuses ...

  14. Chromatography–mass spectrometry in aerospace industry

    International Nuclear Information System (INIS)

    Buryak, Alexey K; Serduk, T M

    2013-01-01

    The applications of chromatography–mass spectrometry in aerospace industry are considered. The primary attention is devoted to the development of physicochemical grounds of the use of various chromatography–mass spectrometry procedures to solve topical problems of this industry. Various methods for investigation of the composition of rocket fuels, surfaces of structural materials and environmental media affected by aerospace activities are compared. The application of chromatography–mass spectrometry for the development and evaluation of processes for decontaminations of equipment, industrial wastes and soils from rocket fuel components is substantiated. The bibliography includes 135 references.

  15. Protein Analysis by Mass Spectrometry

    Directory of Open Access Journals (Sweden)

    Cindic, M.

    2008-04-01

    Full Text Available Soft ionization techniques, electrospray (ESI and matrix-assisted laser desorption/ionization (MALDI make the analysis of biomolecules by mass spectrometry (MS possible. MS is used for determination of the molecular weight of peptides and protein, sequence analysis, characterization of protein-ligand interactions etc. The detection limit, resolution and mass accuracy depend on instrument used (Table 1. Impurities (buffers, salts, detergents can reduce the ion intensities or even totally suppress them, so a separation method (chromatography, 2D-gel electrophoresis must be used for purification of the sample.Molecular mass of intact protein can be determined by ESI or MALDI MS. Multiply charged ions are produced by ESI MS, while singly charged ions are predominant in MALDI spectra (Fig. 2.Sequence analysis of proteins by MS can be performed using peptide mass fingerprint. In this method, proteins are separated by 2-D gel electrophoresis and digested with specific protease (Table 2 or digested and then separated by two-dimensional chromatography (Fig. 1. The obtained peptide mixtures are analyzed by MS or MALDI-TOF technique. The masses determined by MS are compared with calculated masses from database entries. Different algorithms have been developed for protein identification. Example of posttranslational modifications (N- and O-glycosylation and protein sequence complex analysis after dual digestion (endoproteinase digestion followed by endoglycosidase digestion is shown in Fig. 3.It is known that detection of peptides by MS is influenced by intrinsic properties like amino acid composition, the basicity of the C-terminal amino acid, hydrophobicity, etc. Arginine-containing peptides dominate in MS spectra of tryptic digest, so the chemical derivatization of lysine terminal residue by O-methilisourea or 2-methoxy-4,5-1H-imidazole was suggested (Fig. 4.The peptide mass fingerprint method can be improved further by peptide fragmentation using tandem

  16. Difraction spectrometry by laser beams

    Directory of Open Access Journals (Sweden)

    Frías, M.

    1988-12-01

    Full Text Available The advances in laser technology have permitted the development of numerous applications, in particular diffraction spectrometry by laser beams for the determination of the distribution curve of the particle sizes of different materials; this permits one to obtain the distribution of particle size in both wet and dry materials. In the present paper a brief description of the technique and its principles is offered. The results obtained with different materials-limestone clay, gypsum, Portland cement and siliceous materials are given.

    Los avances en la tecnología laser han permitido el desarrollo de múltiples aplicaciones, en concreto la espectrometría de difracción de rayos laser para la determinación de la curva de distribución del tamaño de partícula de diferentes materiales, y que permite la obtención de la misma tanto en seco como en húmedo. En este trabajo se hace una descripción breve de la técnica y de sus fundamentos. Se presentan resultados con diferentes materiales: caliza, arcilla, yeso, cemento Portland y materiales silíceos.

  17. Liquid scintillation alpha spectrometry techniques

    International Nuclear Information System (INIS)

    McKlveen, J.W.; McDowell, W.J.

    1984-01-01

    Accurate, quantitative determinations of alpha emitting nuclides by conventional plate counting methods are difficult, because of sample self-absorption problems in counting and because of non-reproducible losses in conventional sample separation methods. Liquid scintillation alpha spectrometry offers an attractive alternative with no sample self-absorption or geometry problems and with 100% counting efficiency. Sample preparation may include extraction of the alpha emitter of interest by a specific organic phase-soluble compound directly into the liquid scintillation counting medium. Detection electronics use energy and pulse-shape discrimination, to yield alpha spectra without beta and gamma background interference. Specific procedures have been developed for gross alpha, uranium, plutonium, thorium and colonium assay. Possibilities for a large number of other applications exist. Accuracy and reproducibility are typically in the 1% range. Backgrounds of the order of 0.01 cpm are readily achievable. The paper will present an overview of liquid scintillation alpha counting techniques and some of the results achieved for specific applications. (orig.)

  18. Ionizing radiations, detection, dosimetry, spectrometry

    International Nuclear Information System (INIS)

    Blanc, D.

    1997-10-01

    A few works in French language are devoted to the detection of radiations. The purpose of this book is to fill a gap.The five first chapters are devoted to the properties of ionizing radiations (x rays, gamma rays, leptons, hadrons, nuclei) and to their interactions with matter. The way of classification of detectors is delicate and is studied in the chapter six. In the chapter seven are studied the statistics laws for counting and the spectrometry of particles is treated. The chapters eight to thirteen study the problems of ionization: charges transport in a gas, ionization chambers (theory of Boag), counters and proportional chambers, counters with 'streamers', chambers with derive, spark detectors, ionization chambers in liquid medium, Geiger-Mueller counters. The use of a luminous signal is the object of the chapters 14 to 16: conversion of a luminous signal in an electric signal, scintillators, use of the Cerenkov radiation. Then, we find the neutron detection with the chapter seventeen and the dosimetry of particles in the chapter eighteen. This book does not pretend to answer to specialists questions but can be useful to physicians, engineers or physics teachers. (N.C.)

  19. Photon spectrometry utilizing neural networks

    International Nuclear Information System (INIS)

    Silveira, R.; Benevides, C.; Lima, F.; Vilela, E.

    2015-01-01

    Having in mind the time spent on the uneventful work of characterization of the radiation beams used in a ionizing radiation metrology laboratory, the Metrology Service of the Centro Regional de Ciencias Nucleares do Nordeste - CRCN-NE verified the applicability of artificial intelligence (artificial neural networks) to perform the spectrometry in photon fields. For this, was developed a multilayer neural network, as an application for the classification of patterns in energy, associated with a thermoluminescent dosimetric system (TLD-700 and TLD-600). A set of dosimeters was initially exposed to various well known medium energies, between 40 keV and 1.2 MeV, coinciding with the beams determined by ISO 4037 standard, for the dose of 10 mSv in the quantity Hp(10), on a chest phantom (ISO slab phantom) with the purpose of generating a set of training data for the neural network. Subsequently, a new set of dosimeters irradiated in unknown energies was presented to the network with the purpose to test the method. The methodology used in this work was suitable for application in the classification of energy beams, having obtained 100% of the classification performed. (authors)

  20. Pyrolysis - gas chromatography - mass spectrometry of lignins

    Energy Technology Data Exchange (ETDEWEB)

    Martin, F; Saiz-Jimenez, C; Gonzalez-Vila, F J

    1979-01-01

    Milled wood lignins from spruce, beech and bamboo were pyrolysed. The high-boiling products of pyrolysis were studied by GLC and mass spectrometry. The forty-three products identified provide information on the structural units of lignin.

  1. Stable isotope mass spectrometry in petroleum exploration

    International Nuclear Information System (INIS)

    Mathur, Manju

    1997-01-01

    The stable isotope mass spectrometry plays an important role to evaluate the stable isotopic composition of hydrocarbons. The isotopic ratios of certain elements in petroleum samples reflect certain characteristics which are useful for petroleum exploration

  2. Mass Spectrometry-Based Biomarker Discovery.

    Science.gov (United States)

    Zhou, Weidong; Petricoin, Emanuel F; Longo, Caterina

    2017-01-01

    The discovery of candidate biomarkers within the entire proteome is one of the most important and challenging goals in proteomic research. Mass spectrometry-based proteomics is a modern and promising technology for semiquantitative and qualitative assessment of proteins, enabling protein sequencing and identification with exquisite accuracy and sensitivity. For mass spectrometry analysis, protein extractions from tissues or body fluids and subsequent protein fractionation represent an important and unavoidable step in the workflow for biomarker discovery. Following extraction of proteins, the protein mixture must be digested, reduced, alkylated, and cleaned up prior to mass spectrometry. The aim of our chapter is to provide comprehensible and practical lab procedures for sample digestion, protein fractionation, and subsequent mass spectrometry analysis.

  3. Radiation Biomarker Research Using Mass Spectrometry

    National Research Council Canada - National Science Library

    Bach, Stephan B; Hubert, Walter

    2007-01-01

    .... This review is intended to give an overview of mass spectrometry and its application to biological systems and biomarker discovery and how that might relate to relevant radiation dosimetry studies...

  4. Mass Spectrometry Analyses of Multicellular Tumor Spheroids.

    Science.gov (United States)

    Acland, Mitchell; Mittal, Parul; Lokman, Noor A; Klingler-Hoffmann, Manuela; Oehler, Martin K; Hoffmann, Peter

    2018-05-01

    Multicellular tumor spheroids (MCTS) are a powerful biological in vitro model, which closely mimics the 3D structure of primary avascularized tumors. Mass spectrometry (MS) has established itself as a powerful analytical tool, not only to better understand and describe the complex structure of MCTS, but also to monitor their response to cancer therapeutics. The first part of this review focuses on traditional mass spectrometry approaches with an emphasis on elucidating the molecular characteristics of these structures. Then the mass spectrometry imaging (MSI) approaches used to obtain spatially defined information from MCTS is described. Finally the analysis of primary spheroids, such as those present in ovarian cancer, and the great potential that mass spectrometry analysis of these structures has for improved understanding of cancer progression and for personalized in vitro therapeutic testing is discussed. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  5. NICHD Biomedical Mass Spectrometry Core Facility

    Data.gov (United States)

    Federal Laboratory Consortium — The NICHD Biomedical Mass Spectrometry Core Facility was created under the auspices of the Office of the Scientific Director to provide high-end mass-spectrometric...

  6. Atom counting with accelerator mass spectrometry

    International Nuclear Information System (INIS)

    Kutschera, Walter

    1995-01-01

    A brief review of the current status and some recent applications of accelerator mass spectrometry (AMS) are presented. Some connections to resonance ionization mass spectroscopy (RIS) as the alternate atom counting method are discussed

  7. Mass spectrometry of long-lived radionuclides

    International Nuclear Information System (INIS)

    Becker, Johanna Sabine.

    2003-01-01

    The capability of determining element concentrations at the trace and ultratrace level and isotope ratios is a main feature of inorganic mass spectrometry. The precise and accurate determination of isotope ratios of long-lived natural and artificial radionuclides is required, e.g. for their environmental monitoring and health control, for studying radionuclide migration, for age dating, for determining isotope ratios of radiogenic elements in the nuclear industry, for quality assurance and determination of the burn-up of fuel material in a nuclear power plant, for reprocessing plants, nuclear material accounting and radioactive waste control. Inorganic mass spectrometry, especially inductively coupled plasma mass spectrometry (ICP-MS) as the most important inorganic mass spectrometric technique today, possesses excellent sensitivity, precision and good accuracy for isotope ratio measurements and practically no restriction with respect to the ionization potential of the element investigated--therefore, thermal ionization mass spectrometry (TIMS), which has been used as the dominant analytical technique for precise isotope ratio measurements of long-lived radionuclides for many decades, is being replaced increasingly by ICP-MS. In the last few years instrumental progress in improving figures of merit for the determination of isotope ratio measurements of long-lived radionuclides in ICP-MS has been achieved by the application of a multiple ion collector device (MC-ICP-MS) and the introduction of the collision cell interface in order to dissociate disturbing argon-based molecular ions, to reduce the kinetic energy of ions and neutralize the disturbing noble gas ions (e.g. of 129 Xe + for the determination of 129 I). The review describes the state of the art and the progress of different inorganic mass spectrometric techniques such as ICP-MS, laser ablation ICP-MS vs. TIMS, glow discharge mass spectrometry, secondary ion mass spectrometry, resonance ionization mass

  8. Mass spectrometry in life science research.

    Science.gov (United States)

    Lehr, Stefan; Markgraf, Daniel

    2016-12-01

    Investigating complex signatures of biomolecules by mass spectrometry approaches has become indispensable in molecular life science research. Nowadays, various mass spectrometry-based omics technologies are available to monitor qualitative and quantitative changes within hundreds or thousands of biological active components, including proteins/peptides, lipids and metabolites. These comprehensive investigations have the potential to decipher the pathophysiology of disease development at a molecular level and to monitor the individual response of pharmacological treatment or lifestyle intervention.

  9. Thirteenth ISMAS symposium cum workshop on spectrometry

    International Nuclear Information System (INIS)

    Aggarwal, S.K.; Jaison, P.G.; Alamelu, D.

    2008-01-01

    Mass spectrometry is an important analytical tool and finds applications in almost all branches of science and technology like Physics, Chemistry, Biology, Material Science, Geology, Nuclear Science, Industry, Oceanography, Environment etc. Innovations in the designs of mass spectrometers coupled with new ionization techniques have further strengthened the capabilities of mass spectrometry for analyzing all types of molecules including thermally labile and non-volatile at concentrations down to femto gram levels. The applications of mass spectrometry to the biomedical sciences have provided a unique, easy and fast approach to genomics, proteomics and metabolomics. The availability of different types of mass spectrometers for inorganic elemental and isotopic composition determination have strengthened the role of mass spectrometry for analyzing all elements starting from hydrogen onwards. It is now possible to carry out speciation analysis using electrospray mass spectrometry. The individual conference papers in the proceedings covers fundamentals of mass spectrometry, qualitative and quantitative aspects and data interpretation, maintenance of mass spectrometers, selection of mass spectrometer, and recent advances in the field. Papers relevant to INIS are indexed separately

  10. Evaluating airborne and ground based gamma spectrometry methods for detecting particulate radioactivity in the environment: a case study of Irish Sea beaches.

    Science.gov (United States)

    Cresswell, A J; Sanderson, D C W

    2012-10-15

    In several places, programmes are in place to locate and recover radioactive particles that have the potential to cause detrimental health effects in any member of the public who may encounter them. A model has been developed to evaluate the use of mobile gamma spectrometry systems within such programmes, with particular emphasis on large volume (16l) NaI(Tl) detectors mounted in low flying helicopters. This model uses a validated Monte Carlo code with assessment of local geochemistry and natural and anthropogenic background radiation concentrations and distributions. The results of the model, applied to the example of particles recovered from beaches in the vicinity of Sellafield, clearly show the ability of rapid airborne surveys conducted at 75 m ground clearance and 120 kph speeds to demonstrate the absence of sources greater than 5 MBq (137)Cs within large areas (10-20 km(2)h(-1)), and identify areas requiring further ground based investigation. Lowering ground clearance for airborne surveys to 15m whilst maintaining speeds covering 1-2 km(2) h(-1) can detect buried (137)Cs sources of 0.5MBq or greater activity. A survey design to detect 100 kBq (137)Cs sources at 10 cm depth has also been defined, requiring surveys at <15m ground clearance and <2 ms(-1) ground speed. The response of airborne systems to the Sellafield particles recovered to date has also been simulated, and the proportion of the existing radiocaesium background in the vicinity of the nuclear site has been established. Finally the rates of area coverage and sensitivities of both airborne and ground based approaches are compared, demonstrating the ability of airborne systems to increase the rate of particle recovery in a cost effective manner. The potential for equipment and methodological developments to improve performance are discussed. Copyright © 2012 Elsevier B.V. All rights reserved.

  11. Air kerma rate estimation by means of in-situ gamma spectrometry: A Bayesian approach

    International Nuclear Information System (INIS)

    Cabal, Gonzalo; Kluson, Jaroslav

    2008-01-01

    Full text: Bayesian inference is used to determine the Air Kerma Rate based on a set of in situ environmental gamma spectra measurements performed with a NaI(Tl) scintillation detector. A natural advantage of such approach is the possibility to quantify uncertainty not only in the Air Kerma Rate estimation but also for the gamma spectra which is unfolded within the procedure. The measurements were performed using a 3'' x 3'' NaI(Tl) scintillation detector. The response matrices of such detection system were calculated using a Monte Carlo code. For the calculations of the spectra as well as the Air Kerma Rate the WinBugs program was used. WinBugs is a dedicated software for Bayesian inference using Monte Carlo Markov chain methods (MCMC). The results of such calculations are shown and compared with other non-Bayesian approachs such as the Scofield-Gold iterative method and the Maximum Entropy Method

  12. Drill-Core Scanning for Radioelements by Gamma-Ray Spectrometry

    DEFF Research Database (Denmark)

    Løvborg, Leif; Wollenberg, H.; Rose-Hansen, J.

    1972-01-01

    A system has been developed for the continuous and stepwise scanning of rock drill cores for gamma-ray spectrometric determinations of uranium, thorium, and potassium. The apparatus accomodates 3- to 4-cm-diameter core as it passes two opposing 2-inch diameter by 3-inch- thick NaI(Tl) detectors, ......, disclosing detailed variations of U and Th. Contents of U and Th determined by scanning of drill core were consistent with the gross gamma-ray counting rates measured in the boreholes. ©1972 Society of Exploration Geophysicists......A system has been developed for the continuous and stepwise scanning of rock drill cores for gamma-ray spectrometric determinations of uranium, thorium, and potassium. The apparatus accomodates 3- to 4-cm-diameter core as it passes two opposing 2-inch diameter by 3-inch- thick NaI(Tl) detectors...

  13. Tandem mass spectrometry at low kinetic energy

    International Nuclear Information System (INIS)

    Cooks, R.G.; Hand, O.W.

    1987-01-01

    Recent progress in mass spectrometry, as applied to molecular analysis, is reviewed with emphasis on tandem mass spectrometry. Tandem instruments use multiple analyzers (sector magnets, quadrupole mass filters and time-of-flight devices) to select particular molecules in ionic form, react them in the gas-phase and then record the mass, momenta or kinetic energies of their products. The capabilities of tandem mass spectrometry for identification of individual molecules or particular classes of compounds in complex mixtures are illustrated. Several different types of experiments can be run using a tandem mass spectrometer; all share the feature of sifting the molecular mixture being analyzed on the basis of chemical properties expressed in terms of ionic mass, kinetic energy or charge state. Applications of mass spectrometry to biological problems often depend upon desorption methods of ionization in which samples are bombarded with particle beams. Evaporation of preformed charged species from the condensed phase into the vacuum is a particularly effective method of ionization. It is suggested that the use of accelerator mass spectrometers be extended to include problems of molecular analysis. In such experiments, low energy tandem mass spectrometry conducted in the eV or keV range of energies, would be followed by further characterization of the production ion beam using high selective MeV collision processes

  14. Mass spectrometry in nuclear science and technology

    International Nuclear Information System (INIS)

    Komori, Takuji

    1985-01-01

    Mass spectrometry has been widely used and playing a very important role in the field of nuclear science and technology. A major reason for this is that not only the types of element but also its isotopes have to be identified and measured in this field. Thus, some applications of this analytical method are reviewed and discussed in this article. Its application to analytical chemistry is described in the second section following an introductory section, which includes subsections for isotropic dilution mass spectrometry, resonance ionization mass spectrometry and isotopic correlation technique. The isotopic ratio measurement for hydrogen, uranium and plutonium as well as nuclear material control and safeguards are also reviewed in this section. In the third section, mass spectrometry is discussed in relation to nuclear reactors, with subsections on natural uranium reactor and neutron flux observation. Some techniques for measuring the burnup fraction, including the heavy isotopic ratio method and fission product monitoring, are also described. In the fourth section, application of mass spectrometry to measurement of nuclear constants, such as ratio of effective cross-sectional area for 235 U, half-life and fission yield is reviewed. (Nogami, K.)

  15. A deviation display method for visualising data in mobile gamma-ray spectrometry.

    OpenAIRE

    Kock, Peder; Finck, Robert R; Nilsson, Jonas M C; Östlund, Karl; Samuelsson, Christer

    2010-01-01

    A real time visualisation method, to be used in mobile gamma-spectrometric search operations using standard detector systems is presented. The new method, called deviation display, uses a modified waterfall display to present relative changes in spectral data over energy and time. Using unshielded (137)Cs and (241)Am point sources and different natural background environments, the behaviour of the deviation displays is demonstrated and analysed for two standard detector types (NaI(Tl) and HPG...

  16. [Imaging Mass Spectrometry in Histopathologic Analysis].

    Science.gov (United States)

    Yamazaki, Fumiyoshi; Seto, Mitsutoshi

    2015-04-01

    Matrix-assisted laser desorption/ionization (MALDI)-imaging mass spectrometry (IMS) enables visualization of the distribution of a range of biomolecules by integrating biochemical information from mass spectrometry with positional information from microscopy. IMS identifies a target molecule. In addition, IMS enables global analysis of biomolecules containing unknown molecules by detecting the ratio of the molecular weight to electric charge without any target, which makes it possible to identify novel molecules. IMS generates data on the distribution of lipids and small molecules in tissues, which is difficult to visualize with either conventional counter-staining or immunohistochemistry. In this review, we firstly introduce the principle of imaging mass spectrometry and recent advances in the sample preparation method. Secondly, we present findings regarding biological samples, especially pathological ones. Finally, we discuss the limitations and problems of the IMS technique and clinical application, such as in drug development.

  17. Sequencing Cyclic Peptides by Multistage Mass Spectrometry

    Science.gov (United States)

    Mohimani, Hosein; Yang, Yu-Liang; Liu, Wei-Ting; Hsieh, Pei-Wen; Dorrestein, Pieter C.; Pevzner, Pavel A.

    2012-01-01

    Some of the most effective antibiotics (e.g., Vancomycin and Daptomycin) are cyclic peptides produced by non-ribosomal biosynthetic pathways. While hundreds of biomedically important cyclic peptides have been sequenced, the computational techniques for sequencing cyclic peptides are still in their infancy. Previous methods for sequencing peptide antibiotics and other cyclic peptides are based on Nuclear Magnetic Resonance spectroscopy, and require large amount (miligrams) of purified materials that, for most compounds, are not possible to obtain. Recently, development of mass spectrometry based methods has provided some hope for accurate sequencing of cyclic peptides using picograms of materials. In this paper we develop a method for sequencing of cyclic peptides by multistage mass spectrometry, and show its advantages over single stage mass spectrometry. The method is tested on known and new cyclic peptides from Bacillus brevis, Dianthus superbus and Streptomyces griseus, as well as a new family of cyclic peptides produced by marine bacteria. PMID:21751357

  18. Mass spectrometry: a revolution in clinical microbiology?

    Science.gov (United States)

    Lavigne, Jean-Philippe; Espinal, Paula; Dunyach-Remy, Catherine; Messad, Nourredine; Pantel, Alix; Sotto, Albert

    2013-02-01

    Recently, different bacteriological laboratory interventions that decrease reporting time have been developed. These promising new broad-based techniques have merit, based on their ability to identify rapidly many bacteria, organisms difficult to grow or newly emerging strains, as well as their capacity to track disease transmission. The benefit of rapid reporting of identification and/or resistance of bacteria can greatly impact patient outcomes, with an improvement in the use of antibiotics, in the reduction of the emergence of multidrug resistant bacteria and in mortality rates. Different techniques revolve around mass spectrometry (MS) technology: matrix-assisted laser desorption ionization time-of-flight mass spectrometry (MALDI-TOF MS), PCR combined with electrospray ionization-mass spectrometry (PCR/ESIMS), iPLEX MassArray system and other new evolutions combining different techniques. This report emphasizes the (r)evolution of these technologies in clinical microbiology.

  19. Neutron spectrometry and dosimetry with ANNs

    International Nuclear Information System (INIS)

    Vega C, H. R.; Hernandez D, V. M.; Gallego, E.; Lorente, A.

    2009-10-01

    Artificial neural networks technology has been applied to unfold the neutron spectra and to calculate the effective dose, the ambient equivalent dose, and the personal dose equivalent for 252 Cf and 241 AmBe neutron sources. A Bonner sphere spectrometry with a 6 LiI(Eu) scintillator was utilized to measure the count rates of the spheres that were utilized as input in two artificial neural networks, one for spectrometry and another for dosimetry. Spectra and the ambient dose equivalent were also obtained with BUNKIUT code and the UTA4 response matrix. With both procedures spectra and ambient dose equivalent agrees in less than 10%. (author)

  20. Atomic electron spectrometry with synchrotron radiation

    International Nuclear Information System (INIS)

    Sorensen, S.L.

    1989-01-01

    Techniques of atomic electron spectrometry were applied to atoms in the gaseous and solid states to derive information about fundamental atomic properties. A new method was developed to measure Coster-Kronig yields in metals by photoionization with synchrotron radiation. Photon-energy sensitive Si L-VV Auger satellites were investigated via electron spectrometry. The krypton 1s photoionization spectrum was measured in an experiment which was motivated by the need to understand the krypton 1s satellite spectrum for calibration of an experiment to measure the mass of the electron antineutrino

  1. Mass Spectrometry in the Home and Garden

    Science.gov (United States)

    Pulliam, Christopher J.; Bain, Ryan M.; Wiley, Joshua S.; Ouyang, Zheng; Cooks, R. Graham

    2015-02-01

    Identification of active components in a variety of chemical products used directly by consumers is described at both trace and bulk levels using mass spectrometry. The combination of external ambient ionization with a portable mass spectrometer capable of tandem mass spectrometry provides high chemical specificity and sensitivity as well as allowing on-site monitoring. These experiments were done using a custom-built portable ion trap mass spectrometer in combination with the ambient ionization methods of paper spray, leaf spray, and low temperature plasma ionization. Bactericides, garden chemicals, air fresheners, and other products were examined. Herbicide applied to suburban lawns was detected in situ on single leaves 5 d after application.

  2. Zero voltage mass spectrometry probes and systems

    Science.gov (United States)

    Cooks, Robert Graham; Wleklinski, Michael Stanley; Bag, Soumabha; Li, Yafeng

    2017-10-10

    The invention generally relates to zero volt mass spectrometry probes and systems. In certain embodiments, the invention provides a system including a mass spectrometry probe including a porous material, and a mass spectrometer (bench-top or miniature mass spectrometer). The system operates without an application of voltage to the probe. In certain embodiments, the probe is oriented such that a distal end faces an inlet of the mass spectrometer. In other embodiments, the distal end of the probe is 5 mm or less from an inlet of the mass spectrometer.

  3. Alpha and beta detection and spectrometry

    International Nuclear Information System (INIS)

    Saro, S.

    1984-01-01

    The theory of alpha and beta radioactive decay, the interaction of alpha and beta particles with matter, and their detection and spectrometry are dealt with in seven chapters: 1. Alpha transformation of atomic nuclei; 2. Basic properties of detectors and statistics of detection; 3. Alpha detectors and spectrometers; 4. Applications of alpha detection and spectrometry; 5. Beta transformation of atomic nuclei; 6. Beta particle detectors and spectrometers; 7. Detection of low energy beta particles. Chapter 8 is devoted to sampling and preparation of samples for radiometry. (E.F.)

  4. Analysis of mass spectrometry data in proteomics

    DEFF Research Database (Denmark)

    Matthiesen, Rune; Jensen, Ole N

    2008-01-01

    The systematic study of proteins and protein networks, that is, proteomics, calls for qualitative and quantitative analysis of proteins and peptides. Mass spectrometry (MS) is a key analytical technology in current proteomics and modern mass spectrometers generate large amounts of high-quality data...... that in turn allow protein identification, annotation of secondary modifications, and determination of the absolute or relative abundance of individual proteins. Advances in mass spectrometry-driven proteomics rely on robust bioinformatics tools that enable large-scale data analysis. This chapter describes...... some of the basic concepts and current approaches to the analysis of MS and MS/MS data in proteomics....

  5. Chemical analysis of refractories by plasma spectrometry

    International Nuclear Information System (INIS)

    Coutinho, C.A.

    1990-01-01

    X-ray spectrometry has been, since the last two or three decades, the traditional procedure for the chemical analysis of refractories, due to its high degree of accuracy and speed to produce analytical results. An interesting alternative to X-ray fluorescence is provided by the Inductively Coupled Plasma Spectrometry technique, for those laboratories where wet chemistry facilities are already available or process control is not required at high speed, or investiment costs have to be low. This paper presents results obtained by plasma spectroscopy for the analysis of silico - aluminous refractories, showing calibration curves, precion and detection limits. Considerations and comparisons with X-ray fluorescence are also made. (author) [pt

  6. An automatic sample changer for gamma spectrometry

    International Nuclear Information System (INIS)

    Andrews, D.J.

    1984-01-01

    An automatic sample changer for gamma spectrometry is described which is designed for large-volume, low radioactivity environmental samples of various sizes up to maximum dimensions 100 mm diameter x 60 mm high. The sample changer is suitable for use with most existing gamma spectrometry systems which utilize GeLi or NaI detectors in vertical mode, in conjunction with a pulse height analyzer having auto-cycle and suitable data output facilities; it is linked to a Nuclear Data ND 6620 computer-based analysis system. (U.K.)

  7. Analog to digital conversion for nuclear spectrometry

    International Nuclear Information System (INIS)

    Carvalho, P.V.R. de.

    1982-04-01

    A study of the analog to digital conversion techniques for nuclear spectrometry is presented and the main design philosophies of nuclear ADC's are compared. Among them, the most suitable for the current Brazilian conditions, concerning the specifications and components avaiability is the one that employs a statistical correction of successive approximation converters. This technique is described in full detail. A prototype has been developed an tested for the practical demonstration of the theoretical conclusions. These tests was carried on nuclear spectrometry data aquisition system whose implementation is also described. (Author) [pt

  8. Fast neutron spectrometry and dosimetry; Spectrometrie et dosimetrie des neutrons rapides

    Energy Technology Data Exchange (ETDEWEB)

    Blaize, S; Ailloud, J; Mariani, J; Millot, J P [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1958-07-01

    We have studied fast neutron spectrometry and dosimetry through the recoil protons they produce in hydrogenated samples. In spectrometric, we used nuclear emulsions, in dosimetric, we used polyethylene coated with zinc sulphide and placed before a photomultiplier. (author)Fren. [French] Nous avons etudie la spectrometrie et la dosimetrie des neutrons rapides en utilisant les protons de recul qu'ils produisent dans une matiere hydrogenee. En spectrometrie, nous avons employe des emulsions nucleaires, en dosimetrie, du polyethylene recouvert de sulfure de zinc place devant un photomultiplicateur. (auteur)

  9. Multidimensional Gamma-Ray Spectrometry and its Use in Biology; La Spectrometry Gamma Multidimensionnelle et son Application en Biologie; Mnogomernaya spektrometriya gamma-luchej i ee ispol'zovanie v biologii; La Espectrometria Gamma Multidimensional y su Empleo en Biologia

    Energy Technology Data Exchange (ETDEWEB)

    Nielsen, J. M.; Kornberg, H. A. [Battelle Memorial Institute, Pacific Northwest Laboratory, Richland, WA (United States)

    1965-10-15

    Multidimensional gamma-ray spectrometry is a new technique for the measurement of radionuclides which has special application in biology. This instrumental technique allows direct identification and measurement of individual gamma-ray emitters in complex mixtures of radionuclides in diverse sample matrices without prior chemical treatment. The detector system is designed to provide: high sensitivity through use of two large (6-in diam., 4-in thick) Nal(Tl) detectors; high selectivity by using coincidence counting techniques which separate gamma ray spectra by taking advantage of the gamma-ray decay characteristics of each radionuclide ; and ultra-low background and reduced Compton interference through a surrounding anticoincidence annulus detector (a NaI(Tl) crystal 11 Vulgar-Fraction-One-Half -in thick with a 6 Vulgar-Fraction-One-Half - in - diam. hole). A 4096-channel multidimensional analyser analyses the two gamma-rays in coincidence according to their energies and stores them in the plane of the 64 X 64-channel memory while non-coincident events are stored only on the axes of the memory. This effectively decreases the background and Compton interference by orders of magnitude while greatly improving the selectivity. Direct gamma-ray spectrometric measurement of trace levels of radionuclides in biological samples has been inhibited by the presence of relatively large amounts of natural 4 Degree-Sign K whose 1.47 MeV gamma-radiation has interfered with their measurement. Since most radionuclides decay through emission of two or more gamma-rays in cascade the new technique does provide a direct selective measurement and permits wider application. For example, {sup 22}Na (a naturally occurring cosmic-ray produced radionuclide), {sup 134}Cs and {sup 137}Cs (fission products) can be readily measured at existing levels (in some cases at less than 1 dpmAg) in meat, fish, foodstuffs, as well as in urine, so that uptake-excretion studies are possible. This technique

  10. Identification of bacteria using mass spectrometry techniques

    Czech Academy of Sciences Publication Activity Database

    Krásný, Lukáš; Hynek, R.; Hochel, I.

    2013-01-01

    Roč. 353, NOV 2013 (2013), s. 67-79 ISSN 1387-3806 R&D Projects: GA ČR GAP503/10/0664 Institutional support: RVO:61388971 Keywords : Mass spectrometry * Bacteria * Identification Subject RIV: EE - Microbiology, Virology Impact factor: 2.227, year: 2013

  11. Four decades of joy in mass spectrometry

    NARCIS (Netherlands)

    Nibbering, N.M.M.

    2006-01-01

    Tremendous developments in mass spectrometry have taken place in the last 40 years. This holds for both the science and the instrumental revolutions in this field. In chemistry the research was heavily focused on organic molecules that upon electron ionization fragmented via complex mechanistic

  12. Inductively coupled plasma- mass spectrometry. Chapter 13

    International Nuclear Information System (INIS)

    Mahalingam, T.R.

    1997-01-01

    Inductively Coupled Plasma - Mass Spectrometry (ICP-MS) is a new technique for elemental and isotopic analysis which is currently attracting a great deal of interest. This relatively new technique has found wide applications in different fields of research viz., nuclear, geological, biological and environmental sciences

  13. Peculiarities of the modern neutron spectrometry

    Indian Academy of Sciences (India)

    Abstract. Neutron spectrometry provides many branches of science and technology with the .... of this isotope is close to constant for some intervals of atomic mass. For real ... There are nice reviews on these processes [8] and [9]. The data of ...

  14. Characterization of synthetic peptides by mass spectrometry

    DEFF Research Database (Denmark)

    Prabhala, Bala Krishna; Mirza, Osman Asghar; Højrup, Peter

    2015-01-01

    Mass spectrometry (MS) is well suited for analysis of the identity and purity of synthetic peptides. The sequence of a synthetic peptide is most often known, so the analysis is mainly used to confirm the identity and purity of the peptide. Here, simple procedures are described for MALDI......-TOF-MS and LC-MS of synthetic peptides....

  15. Nanostructure-initiator mass spectrometry biometrics

    Science.gov (United States)

    Leclerc, Marion; Bowen, Benjamin; Northen, Trent

    2015-09-08

    Several embodiments described herein are drawn to methods of identifying an analyte on a subject's skin, methods of generating a fingerprint, methods of determining a physiological change in a subject, methods of diagnosing health status of a subject, and assay systems for detecting an analyte and generating a fingerprint, by nanostructure-initiator mass spectrometry (NIMS).

  16. Optimization of Flame Atomic Absorption Spectrometry for ...

    African Journals Online (AJOL)

    Optimization of Flame Atomic Absorption Spectrometry for Measurement of High Concentrations of Arsenic and Selenium. ... This procedure allowed a rapid determination of As from minimum 4.462 mg/L to higher concentrations without sample pretreatment. Besides As, this method successfully measured Se concentrations ...

  17. Characterization of microbial siderophores by mass spectrometry

    Czech Academy of Sciences Publication Activity Database

    Pluháček, Tomáš; Lemr, Karel; Ghosh, D.; Milde, D.; Novák, Jiří; Havlíček, Vladimír

    2016-01-01

    Roč. 35, č. 1 (2016), s. 35-47 ISSN 0277-7037 R&D Projects: GA MŠk(CZ) LD13038; GA ČR(CZ) GAP206/12/1150; GA MŠk(CZ) LO1509 Institutional support: RVO:61388971 Keywords : iron * siderophores * mass spectrometry Subject RIV: CE - Biochemistry Impact factor: 9.373, year: 2016

  18. Burnup determination of mass spectrometry for nuclear fuels

    International Nuclear Information System (INIS)

    Zhang Chunhua.

    1987-01-01

    The various methods currently being used in burnup determination of nuclear fuels are studied and reviewed. The mass spectrometry method of destructive testing is discussed emphatically. The burnup determination of mass spectrometry includes heavy isotopic abundance ratio method and isotope dilution mass spectrometry used as burnup indicator for the fission products. The former is applied to high burnup level, but the later to various burnup level. According to experiences, some problems which should be noticed in burnup determination of mass spectrometry are presented

  19. Application of gamma spectrometry survey and discussion on data processing

    International Nuclear Information System (INIS)

    Li Ji'an; He Jianguo

    2008-01-01

    This paper analyzed and discussed the different opinions about the measured parameters of gamma spectrometry data, introduced the effect of gamma spectrometry survey to the search for sandstone type uranium deposit. The author believes that it is very necessary to perform some ground gamma spectrometry survey and enforce the development and application of airborne radiometric data so as to carry out the role of gamma spectrometry in the exploration of sandstone type uranium deposit. (authors)

  20. The combined measurement of uranium by alpha spectrometry and secondary ion mass spectrometry (SIMS)

    International Nuclear Information System (INIS)

    Harvan, D.

    2009-01-01

    The aim of thesis was to found the dependence between radiometric method - alpha spectrometry and surface sensitive method - Secondary Ion Mass Spectrometry (SIMS). Uranium or naturally occurring uranium isotopes were studied. Samples (high polished stainless steel discs) with uranium isotopes were prepared by electrodeposition. Samples were measured by alpha spectrometry after electrodeposition and treatment. It gives surface activities. Weights, as well as surface's weights of uranium isotopes were calculated from their activities, After alpha spectrometry samples were analyzed by TOF-SIMS IV instrument in International Laser Centre in Bratislava. By the SIMS analysis intensities of uranium-238 were obtained. The interpretation of SIMS intensities vs. surface activity, or surface's weights of uranium isotopes indicates the possibility to use SIMS in quantitative analysis of surface contamination by uranium isotopes, especially 238 U. (author)

  1. High-sensitivity mass spectrometry with a tandem accelerator

    International Nuclear Information System (INIS)

    Henning, W.

    1984-01-01

    The characteristic features of accelerator mass spectrometry are discussed. A short overview is given of the current status of mass spectrometry with high-energy (MeV/nucleon) heavy-ion accelerators. Emphasis is placed on studies with tandem accelerators and on future mass spectrometry of heavier isotopes with the new generation of higher-voltage tandems

  2. Determination of plutonium-238 in plutonium by alpha spectrometry

    International Nuclear Information System (INIS)

    Aggarwal, S.K.; Jain, H.C.; Mathews, C.K.; Ramaniah, M.V.

    1975-01-01

    A method is presented for the determination of 238 Pu in plutonium samples by alpha spectrometry. Various factors attributing towards the energy degradation, a problem usually encountered in alpha spectrometry, are discussed. A computer programme is given for the evaluation of peak areas when the alpha spectrum is degraded. The results are compared with those obtained by mass spectrometry. (author)

  3. A history of mass spectrometry in Australia

    Energy Technology Data Exchange (ETDEWEB)

    Downard, K.M.; de Laeter, J.R. [University of Sydney, Sydney, NSW (Australia)

    2005-09-01

    An interest in mass spectrometry in Australia can be traced back to the 1920s with an early correspondence with Francis Aston who first visited these shores a decade earlier. The region has a rich tradition in both the development of the field and its application, from early measurements of ionization and appearance potentials by Jim Morrison at the Council for Scientific and Industrial Research (CSIR) around 1950 to the design and construction of instrumentation including the first use of a triple quadrupole mass spectrometer for tandem mass spectrometry, the first suite of programs to simulate ion optics (SIMION), the development of early TOF/TOF instruments and orthogonal acceleration and the local design and construction of several generations of a sensitive high-resolution ion microprobe (SHRIMP) instrument. Mass spectrometry has been exploited in the study and characterization of the constituents of this nation's unique flora and fauna from Australian apples, honey, tea plant and eucalyptus oil, snake, spider, fish and frog venoms, coal, oil, sediments and shale, environmental studies of groundwater to geochronological dating of limestone and granite, other terrestrial and meteoritic rocks and coral from the Great Barrier Reef. This article traces the history of mass spectrometry in its many guises and applications in the island continent of Australia. It focuses on contributions of scientists who played a major role in the early establishment of mass spectrometry in Australia. In general, those who are presently active in the field, and whose histories are incomplete, have been mentioned at best only briefly despite their important contributions to the field.

  4. Thermal ionisation mass spectrometry (TIMS): what, how and why?

    International Nuclear Information System (INIS)

    Aggarwal, S.K.

    2002-01-01

    Thermal ionisation mass spectrometry (TIMS) is one of the oldest mass spectrometric techniques, which has been used for determining the isotopic composition and concentration of different elements using isotope dilution. In spite of the introduction of many other inorganic mass spectrometric techniques like spark source mass spectrometry (SSMS), glow discharge mass spectrometry (GDMS), inductively coupled plasma-mass spectrometry (ICP-MS), secondary ion mass spectrometry (SIMS), the TIMS technique plays the role of a definitive analytical methodology and still occupies a unique position in terms of its capabilities with respect to precision and accuracy as well as sensitivity

  5. Auger spectrometry of atoms and molecules

    International Nuclear Information System (INIS)

    Krause, M.O.

    1994-01-01

    The author discusses the importance of Auger spectrometry at synchrotron radiation centers. First, he explains how a high energy photon source such as the APS (Advanced Photon Source) could be used to help provide missing spectral information about the shell structure of some elements. The missing data occurs mainly at higher energies in the 1--10 keV ranges as for the K-shells of Z = 30 to 60 elements and the L-shells for Z = 30 to 100 elements. He explains how even though Auger electron spectrometry does not depend on synchrotron radiation it can greatly benefit from this variable photon source as it allows one to select the Auger line group that is most suitable for a specific purpose. Most significantly, a continuous photon source becomes indispensable when one is interested in threshold effects. Lastly, he discusses coherence effects between different inner-shell vacancy states by way of some recent work done at Daresbury

  6. Accelerator mass spectrometry: state of the art

    Energy Technology Data Exchange (ETDEWEB)

    Tuniz, C. [Australian Nuclear Science and Technology Organisation, Lucas Heights, NSW (Australia)

    1996-12-31

    Accelerator Mass Spectrometry (AMS) is the analytical technique of choice for the detection of long-lived radionuclides which cannot be practically analysed with decay counting or conventional mass spectrometry. The main use of AMS has been in the analysis of radiocarbon and other cosmogenic radionuclides for archaeological, geological and environmental applications. In addition, AMS has been recently applied in biomedicine to study exposure of human tissues to chemicals and biomolecules at attomole levels. There is also a world-wide effort to analyse rare nuclides of heavier masses, such as long-lived actinides, with important applications in safeguards and nuclear waste disposal. The use of AMS is limited by the expensive accelerator technology required and there are several attempts to develop smaller and cheaper AMS spectrometers. 5 refs.

  7. Accelerator mass spectrometry: state of the art

    Energy Technology Data Exchange (ETDEWEB)

    Tuniz, C [Australian Nuclear Science and Technology Organisation, Lucas Heights, NSW (Australia)

    1997-12-31

    Accelerator Mass Spectrometry (AMS) is the analytical technique of choice for the detection of long-lived radionuclides which cannot be practically analysed with decay counting or conventional mass spectrometry. The main use of AMS has been in the analysis of radiocarbon and other cosmogenic radionuclides for archaeological, geological and environmental applications. In addition, AMS has been recently applied in biomedicine to study exposure of human tissues to chemicals and biomolecules at attomole levels. There is also a world-wide effort to analyse rare nuclides of heavier masses, such as long-lived actinides, with important applications in safeguards and nuclear waste disposal. The use of AMS is limited by the expensive accelerator technology required and there are several attempts to develop smaller and cheaper AMS spectrometers. 5 refs.

  8. [Sample preparation and bioanalysis in mass spectrometry].

    Science.gov (United States)

    Bourgogne, Emmanuel; Wagner, Michel

    2015-01-01

    The quantitative analysis of compounds of clinical interest of low molecular weight (sample preparation. Sample preparation is a crucial part of chemical/biological analysis and in a sense is considered the bottleneck of the whole analytical process. The main objectives of sample preparation are the removal of potential interferences, analyte preconcentration, and converting (if needed) the analyte into a more suitable form for detection or separation. Without chromatographic separation, endogenous compounds, co-eluted products may affect a quantitative method in mass spectrometry performance. This work focuses on three distinct parts. First, quantitative bioanalysis will be defined, different matrices and sample preparation techniques currently used in bioanalysis by mass spectrometry of/for small molecules of clinical interest in biological fluids. In a second step the goals of sample preparation will be described. Finally, in a third step, sample preparation strategies will be made either directly ("dilute and shoot") or after precipitation.

  9. Neutron fluence spectrometry using disk activation

    International Nuclear Information System (INIS)

    Loevestam, Goeran; Hult, Mikael; Fessler, Andreas; Gasparro, Joel; Kockerols, Pierre; Okkinga, Klaas; Tagziria, Hamid; Vanhavere, Filip; Wieslander, J.S. Elisabeth

    2009-01-01

    A simple and robust detector for spectrometry of environmental neutrons has been developed. The technique is based on neutron activation of a series of different metal disks followed by low-level gamma-ray spectrometry of the activated disks and subsequent neutron spectrum unfolding. The technique is similar to foil activation but here the applied neutron fluence rates are much lower than usually in the case of foil activation. The detector has been tested in quasi mono-energetic neutron fields with fluence rates in the order of 1000-10000 cm -2 s -1 , where the obtained spectra showed good agreement with spectra measured using a Bonner sphere spectrometer. The detector has also been tested using an AmBe source and at a neutron fluence rate of about 40 cm -2 s -1 , again, a good agreement with the assumed spectrum was achieved

  10. Neutron fluence spectrometry using disk activation

    Energy Technology Data Exchange (ETDEWEB)

    Loevestam, Goeran [EC-JRC-Institute for Reference Materials and Measurements (IRMM), Retieseweg 111, B-2440 Geel (Belgium)], E-mail: goeran.loevestam@ec.europa.eu; Hult, Mikael; Fessler, Andreas; Gasparro, Joel; Kockerols, Pierre; Okkinga, Klaas [EC-JRC-Institute for Reference Materials and Measurements (IRMM), Retieseweg 111, B-2440 Geel (Belgium); Tagziria, Hamid [EC-JRC-Institute for the Protection and the Security of the Citizen (IPSC), Via E. Fermi 1, I-21020 Ispra (Vatican City State, Holy See,) (Italy); Vanhavere, Filip [SCK-CEN, Boeretang, 2400 Mol (Belgium); Wieslander, J.S. Elisabeth [EC-JRC-Institute for Reference Materials and Measurements (IRMM), Retieseweg 111, B-2440 Geel (Belgium); Department of Physics, P.O. Box 35 (YFL), FIN-40014, University of Jyvaeskylae (Finland)

    2009-01-15

    A simple and robust detector for spectrometry of environmental neutrons has been developed. The technique is based on neutron activation of a series of different metal disks followed by low-level gamma-ray spectrometry of the activated disks and subsequent neutron spectrum unfolding. The technique is similar to foil activation but here the applied neutron fluence rates are much lower than usually in the case of foil activation. The detector has been tested in quasi mono-energetic neutron fields with fluence rates in the order of 1000-10000 cm{sup -2} s{sup -1}, where the obtained spectra showed good agreement with spectra measured using a Bonner sphere spectrometer. The detector has also been tested using an AmBe source and at a neutron fluence rate of about 40 cm{sup -2} s{sup -1}, again, a good agreement with the assumed spectrum was achieved.

  11. Phylogenetic Analysis Using Protein Mass Spectrometry.

    Science.gov (United States)

    Ma, Shiyong; Downard, Kevin M; Wong, Jason W H

    2017-01-01

    Through advances in molecular biology, comparative analysis of DNA sequences is currently the cornerstone in the study of molecular evolution and phylogenetics. Nevertheless, protein mass spectrometry offers some unique opportunities to enable phylogenetic analyses in organisms where DNA may be difficult or costly to obtain. To date, the methods of phylogenetic analysis using protein mass spectrometry can be classified into three categories: (1) de novo protein sequencing followed by classical phylogenetic reconstruction, (2) direct phylogenetic reconstruction using proteolytic peptide mass maps, and (3) mapping of mass spectral data onto classical phylogenetic trees. In this chapter, we provide a brief description of the three methods and the protocol for each method along with relevant tools and algorithms.

  12. Guideline on Isotope Dilution Mass Spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Gaffney, Amy [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States)

    2017-05-19

    Isotope dilution mass spectrometry is used to determine the concentration of an element of interest in a bulk sample. It is a destructive analysis technique that is applicable to a wide range of analytes and bulk sample types. With this method, a known amount of a rare isotope, or ‘spike’, of the element of interest is added to a known amount of sample. The element of interest is chemically purified from the bulk sample, the isotope ratio of the spiked sample is measured by mass spectrometry, and the concentration of the element of interest is calculated from this result. This method is widely used, although a mass spectrometer required for this analysis may be fairly expensive.

  13. Monolithic multinozzle emitters for nanoelectrospray mass spectrometry

    Science.gov (United States)

    Wang, Daojing [Daly City, CA; Yang, Peidong [Kensington, CA; Kim, Woong [Seoul, KR; Fan, Rong [Pasadena, CA

    2011-09-20

    Novel and significantly simplified procedures for fabrication of fully integrated nanoelectrospray emitters have been described. For nanofabricated monolithic multinozzle emitters (NM.sup.2 emitters), a bottom up approach using silicon nanowires on a silicon sliver is used. For microfabricated monolithic multinozzle emitters (M.sup.3 emitters), a top down approach using MEMS techniques on silicon wafers is used. The emitters have performance comparable to that of commercially-available silica capillary emitters for nanoelectrospray mass spectrometry.

  14. Mass Spectrometry Imaging under Ambient Conditions

    Science.gov (United States)

    Wu, Chunping; Dill, Allison L.; Eberlin, Livia S.; Cooks, R. Graham; Ifa, Demian R.

    2012-01-01

    Mass spectrometry imaging (MSI) has emerged as an important tool in the last decade and it is beginning to show potential to provide new information in many fields owing to its unique ability to acquire molecularly specific images and to provide multiplexed information, without the need for labeling or staining. In MSI, the chemical identity of molecules present on a surface is investigated as a function of spatial distribution. In addition to now standard methods involving MSI in vacuum, recently developed ambient ionization techniques allow MSI to be performed under atmospheric pressure on untreated samples outside the mass spectrometer. Here we review recent developments and applications of MSI emphasizing the ambient ionization techniques of desorption electrospray ionization (DESI), laser ablation electrospray ionization (LAESI), probe electrospray ionization (PESI), desorption atmospheric pressure photoionization (DAPPI), femtosecond laser desorption ionization (fs-LDI), laser electrospray mass spectrometry (LEMS), infrared laser ablation metastable-induced chemical ionization (IR-LAMICI), liquid microjunction surface sampling probe mass spectrometry (LMJ-SSP MS), nanospray desorption electrospray ionization (nano-DESI), and plasma sources such as the low temperature plasma (LTP) probe and laser ablation coupled to flowing atmospheric-pressure afterglow (LA-FAPA). Included are discussions of some of the features of ambient MSI including the ability to implement chemical reactions with the goal of providing high abundance ions characteristic of specific compounds of interest and the use of tandem mass spectrometry to either map the distribution of targeted molecules with high specificity or to provide additional MS information in the structural identification of compounds. We also describe the role of bioinformatics in acquiring and interpreting the chemical and spatial information obtained through MSI, especially in biological applications for tissue

  15. Accelerator mass spectrometry - From DNA to astrophysics

    International Nuclear Information System (INIS)

    Kutschera, W.

    2013-01-01

    A brief review of accelerator mass spectrometry (AMS) is presented. The present work touches on a few technical aspects and recent developments of AMS, and describes two specific applications of AMS, the dating of human DNA with the 14 C bomb peak and the search for superheavy elements in nature. Since two extended general reviews on technical developments in AMS [1] and applications of AMS [2] will appear in 2013, frequent reference to these reviews is made. (authors)

  16. Polymer and Additive Mass Spectrometry Literature Review

    Energy Technology Data Exchange (ETDEWEB)

    Shear, Trevor Allan [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2017-06-06

    The use of mass spectrometry in fields related to polymers has increased significantly over the past three decades and will be explored in this literature review. The importance of this technique is highlighted when exploring how polymers degrade, verifying purchased materials, and as internal requirements change. The primary focus will be on four ionization techniques and the triple quadrupole and quadrupole / time-of-flight mass spectrometers. The advantages and limitations of each will also be explored.

  17. A mass spectrometry proteomics data management platform.

    Science.gov (United States)

    Sharma, Vagisha; Eng, Jimmy K; Maccoss, Michael J; Riffle, Michael

    2012-09-01

    Mass spectrometry-based proteomics is increasingly being used in biomedical research. These experiments typically generate a large volume of highly complex data, and the volume and complexity are only increasing with time. There exist many software pipelines for analyzing these data (each typically with its own file formats), and as technology improves, these file formats change and new formats are developed. Files produced from these myriad software programs may accumulate on hard disks or tape drives over time, with older files being rendered progressively more obsolete and unusable with each successive technical advancement and data format change. Although initiatives exist to standardize the file formats used in proteomics, they do not address the core failings of a file-based data management system: (1) files are typically poorly annotated experimentally, (2) files are "organically" distributed across laboratory file systems in an ad hoc manner, (3) files formats become obsolete, and (4) searching the data and comparing and contrasting results across separate experiments is very inefficient (if possible at all). Here we present a relational database architecture and accompanying web application dubbed Mass Spectrometry Data Platform that is designed to address the failings of the file-based mass spectrometry data management approach. The database is designed such that the output of disparate software pipelines may be imported into a core set of unified tables, with these core tables being extended to support data generated by specific pipelines. Because the data are unified, they may be queried, viewed, and compared across multiple experiments using a common web interface. Mass Spectrometry Data Platform is open source and freely available at http://code.google.com/p/msdapl/.

  18. Radiocarbon accelerator mass spectrometry: background and contamination

    International Nuclear Information System (INIS)

    Beukens, R.P.

    1993-01-01

    Since the advent of radiocarbon accelerator mass spectrometry (AMS) many studies have been conducted to understand the background from mass spectrometric processes and the origins of contamination associated with the ion source and sample preparation. By studying the individual contributions a better understanding of these processes has been obtained and it has been demonstrated that it is possible to date samples reliably up to 60 000 BP. (orig.)

  19. Optimization Of A Mass Spectrometry Process

    International Nuclear Information System (INIS)

    Lopes, Jose; Alegria, F. Correa; Redondo, Luis; Barradas, N. P.; Alves, E.; Rocha, Jorge

    2011-01-01

    In this paper we present and discuss a system developed in order to optimize the mass spectrometry process of an ion implanter. The system uses a PC to control and display the mass spectrum. The operator interacts with the I/O board, that interfaces with the computer and the ion implanter by a LabVIEW code. Experimental results are shown and the capabilities of the system are discussed.

  20. High resolution spectrometry for relativistic heavy ions

    Energy Technology Data Exchange (ETDEWEB)

    Gabor, G; Schimmerling, W; Greiner, D; Bieser, F; Lindstrom, P [California Univ., Berkeley (USA). Lawrence Berkeley Lab.

    1975-12-01

    Several techniques are discussed for velocity and energy spectrometry of relativistic heavy ions with good resolution. A foil telescope with chevron channel plate detectors is described. A test of this telescope was performed using 2.1 GeV/A C/sup 6 +/ ions, and a time-of-flight resolution of 160 ps was measured. Qualitative information on the effect of foil thickness was also obtained.

  1. Fourier transform ion cyclotron resonance mass spectrometry

    Science.gov (United States)

    Marshall, Alan G.

    1998-06-01

    As for Fourier transform infrared (FT-IR) interferometry and nuclear magnetic resonance (NMR) spectroscopy, the introduction of pulsed Fourier transform techniques revolutionized ion cyclotron resonance mass spectrometry: increased speed (factor of 10,000), increased sensitivity (factor of 100), increased mass resolution (factor of 10,000-an improvement not shared by the introduction of FT techniques to IR or NMR spectroscopy), increased mass range (factor of 500), and automated operation. FT-ICR mass spectrometry is the most versatile technique for unscrambling and quantifying ion-molecule reaction kinetics and equilibria in the absence of solvent (i.e., the gas phase). In addition, FT-ICR MS has the following analytically important features: speed (~1 second per spectrum); ultrahigh mass resolution and ultrahigh mass accuracy for analysis of mixtures and polymers; attomole sensitivity; MSn with one spectrometer, including two-dimensional FT/FT-ICR/MS; positive and/or negative ions; multiple ion sources (especially MALDI and electrospray); biomolecular molecular weight and sequencing; LC/MS; and single-molecule detection up to 108 Dalton. Here, some basic features and recent developments of FT-ICR mass spectrometry are reviewed, with applications ranging from crude oil to molecular biology.

  2. Spectrometry of degraded neutrons with SSNTDs

    International Nuclear Information System (INIS)

    Gopalani, Deepak; Kumar, S.; Jodha, A.S.; Reddy, A.R.

    1993-01-01

    Considerable interest has grown during the last decade in the use of solid state nuclear track detectors (SSNTDs) for routine neutron monitoring and dosimetry work. In addition, using these detectors neutron spectrometry has also been undertaken by some investigators. In spectrometry the energy of neutrons was determined either from minor axis of proton tracks observed on the surface of detector or from the use of polyethylene radiators of selected thickness with varying etching time. Using this latter method in the present work fast neutron spectrometry is made. The method involves the measurement of etch induction time, thickness of removed critical layer for constant radiator thickness with varying etching time. Besides a computer programme has been developed for the calculation of neutron sensitivity at different critical removal layers. The degraded neutron spectra of 252 Cf with shield materials of different thickness but of same composition and shield materials of same thickness but of different compositions have been obtained. The study shows that SSNTD films can be used for recording the transmitted neutron spectra from different shield materials. This spectrometric capability added to the technique advantages of SSNTDs such as integrating nature and small size make them important for nuclear engineering applications. (author). 7 refs., 4 figs., 1 tab

  3. Radiation dosimetry and spectrometry with superheated emulsions

    International Nuclear Information System (INIS)

    D'Errico, Francesco

    2001-01-01

    Detectors based on emulsions of overexpanded halocarbon droplets in tissue equivalent aqueous gels or soft polymers, known as 'superheated drop detectors' or 'bubble (damage) detectors', have been used in radiation detection, dosimetry and spectrometry for over two decades. Recent technological advances have led to the introduction of several instruments for individual and area monitoring: passive integrating meters based on the optical or volumetric registration of the bubbles, and active counters detecting bubble nucleations acoustically. These advances in the instrumentation have been matched by the progress made in the production of stable and well-specified emulsions of superheated droplets. A variety of halocarbons are employed in the formulation of the detectors, and this permits a wide range of applications. In particular, halocarbons with a moderate degree of superheat, i.e. a relatively small difference between their operating temperature and boiling point, can be used in neutron dosimetry and spectrometry since they are only nucleated by energetic heavy ions such as those produced by fast neutrons. More recently, halocarbons with an elevated degree of superheat have been utilised to produce emulsions that nucleate with much smaller energy deposition and detect low linear energy transfer radiations, such as photons and electrons. This paper reviews the detector physics of superheated emulsions and their applications in radiation measurements, particularly in neutron dosimetry and spectrometry

  4. Study on the natural radioactivity from the region of Presidente Figueiredo (AM), Brazil, using gamma spectrometry; Estudo da radioatividade natural da regiao de Presidente Figueiredo (AM) utilizando espectrometria gama

    Energy Technology Data Exchange (ETDEWEB)

    Da Silva, Jose Ribamar Silveira

    1999-07-01

    A gamma spectrometry profile was carried out along BR174 highway, that crosses some lithostratigraphic units of the North portion of the Sedimentary Basin of Amazon. Measurements in situ were realized in 116 points, 1 km apart, using a GAD-6 gamma-spectrometer and samples of rocks and soils were collected in geologically representative points, for gamma measurements using a shielded detector of NaI(Tl) available in the Nuclear Geophysics Laboratory of IAG/USP. The criterion used for evaluating the reliability degree of the concentration values of eU (ppm), eTh (ppm) and %K was to establish mathematically detection limits, for all measurement points. Every these points had been located using GPS with accuracy of 50 m to become possible a future detailed study. The purpose of matching portable gamma spectrometer and laboratory determinations was to compare the 2 techniques, using the criterion of detectability limits, and to verify the influence of {sup 222} Rn atmospheric radioactive gas in field measurements. In the case of portable detector, it allows fast measurements and the sensor 'sees' a big volume of material (rock, soil...), that makes it more representative. In some situations where atmospheric phenomena of thermal inversion occurs, measurement can be affected by the {sup 222} Rn cosmic background. Presence of radon daughter elements, associated with aerosols, in this tropical environment (high values of temperature and humidity), where the speed of the wind that could exhaust this gas is practically zero. It is observed that the values of concentration in the some points, got with these 2 techniques, have the same trend, and the stretches where peaks of concentration of K also occur and U and Th are associated with the presence of granite out corps, great boulders, and clay soils from weathering of these rocks. (author)

  5. Study on the natural radioactivity from the region of Presidente Figueiredo (AM), Brazil, using gamma spectrometry; Estudo da radioatividade natural da regiao de Presidente Figueiredo (AM) utilizando espectrometria gama

    Energy Technology Data Exchange (ETDEWEB)

    Da Silva, Jose Ribamar Silveira

    1999-07-01

    A gamma spectrometry profile was carried out along BR174 highway, that crosses some lithostratigraphic units of the North portion of the Sedimentary Basin of Amazon. Measurements in situ were realized in 116 points, 1 km apart, using a GAD-6 gamma-spectrometer and samples of rocks and soils were collected in geologically representative points, for gamma measurements using a shielded detector of NaI(Tl) available in the Nuclear Geophysics Laboratory of IAG/USP. The criterion used for evaluating the reliability degree of the concentration values of eU (ppm), eTh (ppm) and %K was to establish mathematically detection limits, for all measurement points. Every these points had been located using GPS with accuracy of 50 m to become possible a future detailed study. The purpose of matching portable gamma spectrometer and laboratory determinations was to compare the 2 techniques, using the criterion of detectability limits, and to verify the influence of {sup 222} Rn atmospheric radioactive gas in field measurements. In the case of portable detector, it allows fast measurements and the sensor 'sees' a big volume of material (rock, soil...), that makes it more representative. In some situations where atmospheric phenomena of thermal inversion occurs, measurement can be affected by the {sup 222} Rn cosmic background. Presence of radon daughter elements, associated with aerosols, in this tropical environment (high values of temperature and humidity), where the speed of the wind that could exhaust this gas is practically zero. It is observed that the values of concentration in the some points, got with these 2 techniques, have the same trend, and the stretches where peaks of concentration of K also occur and U and Th are associated with the presence of granite out corps, great boulders, and clay soils from weathering of these rocks. (author)

  6. Determination of plutonium isotopes in bilberry using liquid scintillation spectrometry and alpha-particle spectrometry

    International Nuclear Information System (INIS)

    Seferinoğlu, Meryem; Aslan, Nazife; Kurt, Aylin; Erden, Pınar Esra; Mert, Hülya

    2014-01-01

    This paper presents α-particle spectrometry and liquid scintillation spectrometry methods to determine plutonium isotopes in bilberry. The analytical procedure involves sample preparation steps for ashing, digestion of bilberry samples, radiochemical separation of plutonium radioisotopes and their measurement. The validity of the method was checked for coherence using the ζ test, z-test, relative bias and relative uncertainty outlier tests. The results indicated that the recommended procedures for both measurement systems could be successfully applied for the accurate determination of plutonium activities in bilberry samples. - Highlights: • Sample preparation methods for Pu using LSS and alpha spectrometry developed. • Complete separation of plutonium from interfering radionuclides. • Commercial bilberry was spiked with NPL 2011 (AH-B11144) proficiency test sample. • Results were checked using ζ test, z-test, rel. bias and rel. uncert. outlier tests. • Recommended procedures successfully applied to bilberry samples

  7. Study by Auger spectrometry and mass spectrometry of the chemisorption of carbon monoxide on polycrystalline molybdenum

    International Nuclear Information System (INIS)

    Gillet, E.; Chiarena, J.C.; Gillet, M.

    1976-01-01

    A combination of Auger spectrometry and mass spectrometry was employed to study CO chemisorption on polycrystalline Mo surfaces at room temperature. Five adsorption states were observed and the binding parameters (E,n 0 ,tau 0 ) were calculated for the three important states. The results obtained by the two methods are in accord but the occurence of electronic desorption in Auger experiments was pointed out. Contamination effects by C atoms in such studies were investigated by repeated cycles of adsorption-desorption and a characteristic evolution of flash desorption was observed. The results are discussed in this point of view enhancing the importance of a control of the adsorption surface cleanness by a method of great sensibility like Auger spectrometry. (Auth.)

  8. The use of lasers as sources for Raman spectrometry, resonance Raman spectrometry, and light scattering

    International Nuclear Information System (INIS)

    Capitini, R.; Ceccaldi, M.; Leicknam, J.P.; Plus, R.

    1975-01-01

    The activity of the laboratory is principally centred on the determination of molecular structures and the study of molecular interactions in solution by infrared and Raman spectrometry. With the development of work on relatively large molecules, particularly biological molecules, it became necessary to complete information on the molecular weight and on the intra and intermolecular geometry and interactions of these bodies. In order to obtain these informations Rayleigh scattering and resonance Raman spectrometry were used. The advantages of using vibrational spectrometry, particularly Raman, in conjunction with the diffusion of light for these structural and molecular interaction studies is emphasized. It is shown that these two techniques could not have developed as they have done in the last few years without the use of lasers as light source [fr

  9. Silver nanostructures in laser desorption/ionization mass spectrometry and mass spectrometry imaging.

    Science.gov (United States)

    Sekuła, Justyna; Nizioł, Joanna; Rode, Wojciech; Ruman, Tomasz

    2015-09-21

    Silver nanoparticles have been successfully applied as a matrix replacement for the laser desorption/ionization time-of-flight mass spectrometry (LDI-ToF-MS). Nanoparticles, producing spectra with highly reduced chemical background in the low m/z region, are perfectly suited for low-molecular weight compound analysis and imaging. Silver nanoparticles (AgNPs) can efficiently absorb ultraviolet laser radiation, transfer energy to the analyte and promote analyte desorption, but also constitute a source of silver ions suitable for analyte cationisation. This review provides an overview of the literature on silver nanomaterials as non-conventional desorption and ionization promoters in LDI-MS and mass spectrometry imaging.

  10. Performance Test of Alpha Spectrometry for Environmental Radioactivity Analysis

    International Nuclear Information System (INIS)

    Choi, Jung Youn; Yoon, Jong-Ho; Han, Ki-Tek; Ahn, Gil Hoon

    2015-01-01

    Environmental samples are analyzed by various methods such as, ICP-MS (inductively coupled plasma mass spectrometry), AMS (accelerator mass spectrometry) TIMS (thermal ionization mass spectrometry), HRGS (high resolution gamma spectrometry) and alpha /beta particle analysis. In this study, we will described the result of performance test using alpha spectrometry for analyzing environmental samples. Measurement data of the U activity using SRM based on extraction chromatography with UTEVA resin. It should be effective way to separate of uranium isotope for the measurement of alpha spectrometry. But, the result of this measurement data is higher than another recovery data. Also concentration of U data is lack of consistency. We leave out of consideration many effect of factors about influence in the experiment process. In the future work, we will try to reduce the step of experiment process and reflect the uncertainty factors

  11. The emergence of mass spectrometry in biochemical research

    OpenAIRE

    1995-01-01

    The initial steps toward routinely applying mass spectrometry in the biochemical laboratory have been achieved. In the past, mass spectrometry was confined to the realm of small, relatively stable molecules; large or thermally labile molecules did not survive the desorption and ionization processes intact. Electrospray ionization (ESI) and matrix-assisted laser desorption/ionization (MALDI) mass spectrometry allow for the analysis of both small and large biomolecules through "mild" desorption...

  12. Mass spectrometry imaging: Towards a lipid microscope?

    Science.gov (United States)

    Touboul, David; Brunelle, Alain; Laprévote, Olivier

    2011-01-01

    Biological imaging techniques are the most efficient way to locally measure the variation of different parameters on tissue sections. These analyses are gaining increasing interest since 20 years and allow observing extremely complex biological phenomena at lower and lower time and resolution scale. Nevertheless, most of them only target very few compounds of interest, which are chosen a priori, due to their low resolution power and sensitivity. New chemical imaging technique has to be introduced in order to overcome these limitations, leading to more informative and sensitive analyses for biologists and physicians. Two major mass spectrometry methods can be efficiently used to generate the distribution of biological compounds over a tissue section. Matrix-Assisted Laser Desorption/Ionisation-Mass Spectrometry (MALDI-MS) needs the co-crystallization of the sample with a matrix before to be irradiated by a laser, whereas the analyte is directly desorbed by a primary ion bombardment for Secondary Ion Mass Spectrometry (SIMS) experiments. In both cases, energy used for desorption/ionization is locally deposited -some tens of microns for the laser and some hundreds of nanometers for the ion beam- meaning that small areas over the surface sample can be separately analyzed. Step by step analysis allows spectrum acquisitions over the tissue sections and the data are treated by modern informatics software in order to create ion density maps, i.e., the intensity plot of one specific ion versus the (x,y) position. Main advantages of SIMS and MALDI compared to other chemical imaging techniques lie in the simultaneous acquisition of a large number of biological compounds in mixture with an excellent sensitivity obtained by Time-of-Flight (ToF) mass analyzer. Moreover, data treatment is done a posteriori, due to the fact that no compound is selectively marked, and let us access to the localization of different lipid classes in only one complete acquisition. Copyright © 2010

  13. Hydrogen/deuterium exchange in mass spectrometry.

    Science.gov (United States)

    Kostyukevich, Yury; Acter, Thamina; Zherebker, Alexander; Ahmed, Arif; Kim, Sunghwan; Nikolaev, Eugene

    2018-03-30

    The isotopic exchange approach is in use since the first observation of such reactions in 1933 by Lewis. This approach allows the investigation of the pathways of chemical and biochemical reactions, determination of structure, composition, and conformation of molecules. Mass spectrometry has now become one of the most important analytical tools for the monitoring of the isotopic exchange reactions. Investigation of conformational dynamics of proteins, quantitative measurements, obtaining chemical, and structural information about individual compounds of the complex natural mixtures are mainly based on the use of isotope exchange in combination with high resolution mass spectrometry. The most important reaction is the Hydrogen/Deuterium exchange, which is mainly performed in the solution. Recently we have developed the approach allowing performing of the Hydrogen/Deuterium reaction on-line directly in the ionization source under atmospheric pressure. Such approach simplifies the sample preparation and can accelerate the exchange reaction so that certain hydrogens that are considered as non-labile will also participate in the exchange. The use of in-ionization source H/D exchange in modern mass spectrometry for structural elucidation of molecules serves as the basic theme in this review. We will focus on the mechanisms of the isotopic exchange reactions and on the application of in-ESI, in-APCI, and in-APPI source Hydrogen/Deuterium exchange for the investigation of petroleum, natural organic matter, oligosaccharides, and proteins including protein-protein complexes. The simple scenario for adaptation of H/D exchange reactions into mass spectrometric method is also highlighted along with a couple of examples collected from previous studies. © 2018 Wiley Periodicals, Inc.

  14. Neutron spectrometry and dosimetry using NSDAAN

    International Nuclear Information System (INIS)

    Martinez B, M. R.; Vega C, H. R.; Ortiz R, J. M.

    2009-10-01

    The reconstruction of neutron spectra from count rates of a Bonner spheres spectrometric system is performed using various methods such as Monte Carlo methods, the parameterization and iterative methods. The weight of the Bonner spheres spectrometric system, the procedure for the reconstruction of the spectra, the need of an experienced user, the high consumer of time, the need of use a reconstruction code as the BUNKI, SAND, among others, and the resolution of the spectrum are some problems that this system presents. This has motivated the development of complementary procedures such as maximum entropy, genetic algorithms and artificial neural networks. In previous work, has reported a new method called robust design methodology of artificial neural networks, to construct various network topologies capable of solving the problems of neutron spectrometry and dosimetry, however, due to the newness of this technology, be noted that there are not tools to end-user that allow test and validate the designed networks. This paper presents a software for the neutron spectrometry and dosimetry, designed from the information extracted of an artificial neural network designed by robust design methodology of artificial neural networks. This tool has the following characteristics: was designed in a user graphical interface easy to use, requires not knowledge of neural networks or neutron spectrometry by the user; execution speed of the application; unlike the deconvolution codes are not required to select an initial spectrum for the spectrum reconstruction; as an additional element to this tool, besides the spectrum, the calculation is performed simultaneous to H(10), E, H p , s (10,θ) from just counting rates from a Bonner spheres spectrometric system. (author)

  15. Trends in tungsten coil atomic spectrometry

    Science.gov (United States)

    Donati, George L.

    Renewed interest in electrothermal atomic spectrometric methods based on tungsten coil atomizers is a consequence of a world wide increasing demand for fast, inexpensive, sensitive, and portable analytical methods for trace analysis. In this work, tungsten coil atomic absorption spectrometry (WCAAS) and tungsten coil atomic emission spectrometry (WCAES) are used to determine several different metals and even a non-metal at low levels in different samples. Improvements in instrumentation and new strategies to reduce matrix effects and background signals are presented. Investigation of the main factors affecting both WCAAS and WCAES analytical signals points to the importance of a reducing, high temperature gas phase in the processes leading to atomic cloud generation. Some more refractory elements such as V and Ti were determined for the first time by double tungsten coil atomic emission spectrometry (DWCAES). The higher temperatures provided by two atomizers in DWCAES also allowed the detection of Ag, Cu and Sn emission signals for the first time. Simultaneous determination of several elements by WCAES in relatively complex sample matrices was possible after a simple acid extraction. The results show the potential of this method as an alternative to more traditional, expensive methods for fast, more effective analyses and applications in the field. The development of a new metallic atomization cell is also presented. Lower limits of detection in both WCAAS and WCAES determinations were obtained due to factors such as better control of background signal, smaller, more isothermal system, with atomic cloud concentration at the optical path for a longer period of time. Tungsten coil-based methods are especially well suited to applications requiring low sample volume, low cost, sensitivity and portability. Both WCAAS and WCAES have great commercial potential in fields as diverse as archeology and industrial quality control. They are simple, inexpensive, effective

  16. Monte Carlo simulation applied to alpha spectrometry

    International Nuclear Information System (INIS)

    Baccouche, S.; Gharbi, F.; Trabelsi, A.

    2007-01-01

    Alpha particle spectrometry is a widely-used analytical method, in particular when we deal with pure alpha emitting radionuclides. Monte Carlo simulation is an adequate tool to investigate the influence of various phenomena on this analytical method. We performed an investigation of those phenomena using the simulation code GEANT of CERN. The results concerning the geometrical detection efficiency in different measurement geometries agree with analytical calculations. This work confirms that Monte Carlo simulation of solid angle of detection is a very useful tool to determine with very good accuracy the detection efficiency.

  17. Performance of gamma spectrometry counting system

    International Nuclear Information System (INIS)

    Yii Mei Wo; Maziah Mahmud

    2007-01-01

    Gamma spectrometry counting system widely used as tool to measure qualitative and quantitative gamma-ray emitters in a sample. Container size, sample to detector distance, sample volume are well known factors that affecting the quality of measurement. However, factor such as the age of the system was not been reported. Therefore, the objective of this study is to find out how the age factor affecting the quality of the measurement. From this study, it is found that when the age of the system increased, the system tends to have higher lower limit of detection and poorer linearity showing that age factor do affecting the quality of measurement. (Author)

  18. Mass spectrometry by means of tandem accelerators

    International Nuclear Information System (INIS)

    Tuniz, C.

    1985-01-01

    Mass spectrometry based on an accelerator allows to measure rare cosmogenic isotopes found in natural samples with isotopic abundances up to 10E-15. The XTU Tandem of Legnaro National Laboratories can measure mean heavy isotopes (36Cl, 41Ca, 129I) in applications interesting cosmochronology and Medicine. The TTT-3 Tandem of the Naples University has been modified in view of precision studies of C14 in Archeology, Paleantology and Geology. In this paper a review is made of principles and methodologies and of some applicationy in the framework of the National Program for mass spectrametry research with the aid of accelerators

  19. Coherence in electron energy loss spectrometry

    International Nuclear Information System (INIS)

    Schattschneider, P.; Werner, W.S.M.

    2005-01-01

    Coherence effects in electron energy loss spectrometry (EELS) and in energy filtering are largely neglected although they occur frequently due to Bragg scattering in crystals. We discuss how coherence in the inelastically scattered wave field can be described by the mixed dynamic form factor (MDFF), and how it relates to the density matrix of the scattered electrons. Among the many aspects of 'inelastic coherence' are filtered high-resolution images, dipole-forbidden transitions, coherence in plasma excitations, errors in chemical microanalysis, coherent double plasmons, and circular dichroism

  20. Depth resolution of secondary ion mass spectrometry

    International Nuclear Information System (INIS)

    Pustovit, A.N.

    2004-01-01

    The effect of the solid body discreteness in the direction of the normal to the sample surface on the depth resolution of the secondary ion mass spectrometry method is analyzed. It is shown that for this case the dependence of the width at the semi-height of the delta profiles of the studied elements depth distribution on the energy and angle of incidence of the initial ions should have the form of the stepwise function. This is experimentally proved by the silicon-germanium delta-layers in the silicon samples [ru

  1. Methods for recalibration of mass spectrometry data

    Science.gov (United States)

    Tolmachev, Aleksey V [Richland, WA; Smith, Richard D [Richland, WA

    2009-03-03

    Disclosed are methods for recalibrating mass spectrometry data that provide improvement in both mass accuracy and precision by adjusting for experimental variance in parameters that have a substantial impact on mass measurement accuracy. Optimal coefficients are determined using correlated pairs of mass values compiled by matching sets of measured and putative mass values that minimize overall effective mass error and mass error spread. Coefficients are subsequently used to correct mass values for peaks detected in the measured dataset, providing recalibration thereof. Sub-ppm mass measurement accuracy has been demonstrated on a complex fungal proteome after recalibration, providing improved confidence for peptide identifications.

  2. Space Applications of Mass Spectrometry. Chapter 31

    Science.gov (United States)

    Hoffman, John H.; Griffin, Timothy P.; Limero, Thomas; Arkin, C. Richard

    2010-01-01

    Mass spectrometers have been involved in essentially all aspects of space exploration. This chapter outlines some of these many uses. Mass spectrometers have not only helped to expand our knowledge and understanding of the world and solar system around us, they have helped to put man safely in space and expand our frontier. Mass spectrometry continues to prove to be a very reliable, robust, and flexible analytical instrument, ensuring that its use will continue to help aid our investigation of the universe and this small planet that we call home.

  3. Mass spectrometry investigation of magnetron sputtering discharges

    Czech Academy of Sciences Publication Activity Database

    Pokorný, Petr; Musil, Jindřich; Lančok, Ján; Fitl, Přemysl; Novotný, Michal; Bulíř, Jiří; Vlček, Jan

    2017-01-01

    Roč. 143, č. 6 (2017), s. 438-443 ISSN 0042-207X R&D Projects: GA MŠk LO1409; GA MŠk LM2015088; GA TA ČR(CZ) TA03010490; GA ČR GA17-13427S Institutional support: RVO:68378271 Keywords : mass spectrometry * atoms * radicals and ions * RF discharge * contamination * metallic films Subject RIV: BM - Solid Matter Physics ; Magnetism OBOR OECD: Condensed matter physics (including formerly solid state physics, supercond.) Impact factor: 1.530, year: 2016

  4. Laboratory of High resolution gamma spectrometry

    International Nuclear Information System (INIS)

    Mendez G, A.; Giber F, J.; Rivas C, I.; Reyes A, B.

    1992-01-01

    The Department of Nuclear Experimentation of the Nuclear Systems Management requests the collaboration of the Engineering unit for the supervision of the execution of the work of the High resolution Gamma spectrometry and low bottom laboratory, using the hut of the sub critic reactor of the Nuclear Center of Mexico. This laboratory has the purpose of determining the activity of special materials irradiated in nuclear power plants. In this report the architecture development, concepts, materials and diagrams for the realization of this type of work are presented. (Author)

  5. Mass spectrometry a versatile aid to inorganic analysis

    International Nuclear Information System (INIS)

    Stefani, Rene

    1976-01-01

    Several hundred publications have appeared in the last three years that deal with applications of Mass Spectrometry to inorganic analysis. Bulk and localized trace analysis, surface and thin film characterization and microstructure examination are currently performed by Secondary Ion Mass Spectrometry, Spark Source Mass Spectrometry and the newly developed Laser Probe Mass Spectrometry. Suitable experimental procedures allow insulators, biologic materials and microsamples to be analysed. In spite of the classification by techniques this review is essentially devoted to the most significant papers in analytical applications but instrumental and basic features are sometimes introduced to support the discussions

  6. The development of a digital airborne gamma-ray spectrometry

    International Nuclear Information System (INIS)

    Ge Liangquan; Zeng Guoqiang; Lai Wanchang; Fan Zhengguo; Xiong Shengqing; Ni Weichong

    2011-01-01

    In this paper,we report a newly developed AGS instrument. The probe is composed of five 5 NaI(Tl) scintillators of 10 mm x 10 mm x 40 mm size. Four of them detect the ground, and the fifth detects the sky. A temperature sensor, a preamplifier with circuit negative feedback and a high voltage supply with lower noise are designed. A Y/U double channel digital controlled gain amplifier for fine adjustment of the spectral drift,and high speed ADC and CPLD, are designed to perform digital spectroscopy and improve the energy resolution and pulse through output rate(>100 k/s). Two self-stabilization spectrum loops are designed for spectrum stability. The first loop performs rough adjustment (temperature), and the second loop does the fine adjustment by a Kalman filter. The AGS system has the following specifications: energy range of detection, 0.02-10.0 MeV; the spectral drift, ±1 channel; and spectrum collection time of 0.5-1 s. The 20 NaI(Tl)+PMT scintillation counters can be operated at the same time. (authors)

  7. Mass Spectrometry on Future Mars Landers

    Science.gov (United States)

    Brinckerhoff, W. B.; Mahaffy, P. R.

    2011-01-01

    Mass spectrometry investigations on the 2011 Mars Science Laboratory (MSL) and the 2018 ExoMars missions will address core science objectives related to the potential habitability of their landing site environments and more generally the near-surface organic inventory of Mars. The analysis of complex solid samples by mass spectrometry is a well-known approach that can provide a broad and sensitive survey of organic and inorganic compounds as well as supportive data for mineralogical analysis. The science value of such compositional information is maximized when one appreciates the particular opportunities and limitations of in situ analysis with resource-constrained instrumentation in the context of a complete science payload and applied to materials found in a particular environment. The Sample Analysis at Mars (SAM) investigation on MSL and the Mars Organic Molecule Analyzer (MOMA) investigation on ExoMars will thus benefit from and inform broad-based analog field site work linked to the Mars environments where such analysis will occur.

  8. Parsimonious Charge Deconvolution for Native Mass Spectrometry

    Science.gov (United States)

    2018-01-01

    Charge deconvolution infers the mass from mass over charge (m/z) measurements in electrospray ionization mass spectra. When applied over a wide input m/z or broad target mass range, charge-deconvolution algorithms can produce artifacts, such as false masses at one-half or one-third of the correct mass. Indeed, a maximum entropy term in the objective function of MaxEnt, the most commonly used charge deconvolution algorithm, favors a deconvolved spectrum with many peaks over one with fewer peaks. Here we describe a new “parsimonious” charge deconvolution algorithm that produces fewer artifacts. The algorithm is especially well-suited to high-resolution native mass spectrometry of intact glycoproteins and protein complexes. Deconvolution of native mass spectra poses special challenges due to salt and small molecule adducts, multimers, wide mass ranges, and fewer and lower charge states. We demonstrate the performance of the new deconvolution algorithm on a range of samples. On the heavily glycosylated plasma properdin glycoprotein, the new algorithm could deconvolve monomer and dimer simultaneously and, when focused on the m/z range of the monomer, gave accurate and interpretable masses for glycoforms that had previously been analyzed manually using m/z peaks rather than deconvolved masses. On therapeutic antibodies, the new algorithm facilitated the analysis of extensions, truncations, and Fab glycosylation. The algorithm facilitates the use of native mass spectrometry for the qualitative and quantitative analysis of protein and protein assemblies. PMID:29376659

  9. Lipid imaging by mass spectrometry - a review.

    Science.gov (United States)

    Gode, David; Volmer, Dietrich A

    2013-03-07

    Mass spectrometry imaging (MSI) has proven to be extremely useful for applications such as the spatial analysis of peptides and proteins in biological tissue, the performance assessment of drugs in vivo or the measurement of protein or metabolite expression as tissue classifiers or biomarkers from disease versus control tissue comparisons. The most popular MSI technique is MALDI mass spectrometry. First invented by Richard Caprioli in the mid-1990s, it is the highest performing MSI technique in terms of spatial resolution, sensitivity for intact biomolecules and application range today. The unique ability to identify and spatially resolve numerous compounds simultaneously, based on m/z values has inter alia been applied to untargeted and targeted chemical mapping of biological compartments, revealing changes of physiological states, disease pathologies and metabolic faith and distribution of xenobiotics. Many MSI applications focus on lipid species because of the lipids' diverse roles as structural components of cell membranes, their function in the surfactant cycle, and their involvement as second messengers in signalling cascades of tissues and cells. This article gives a comprehensive overview of lipid imaging techniques and applications using established MALDI and SIMS methods but also other promising MSI techniques such as DESI.

  10. Impact of automation on mass spectrometry.

    Science.gov (United States)

    Zhang, Yan Victoria; Rockwood, Alan

    2015-10-23

    Mass spectrometry coupled to liquid chromatography (LC-MS and LC-MS/MS) is an analytical technique that has rapidly grown in popularity in clinical practice. In contrast to traditional technology, mass spectrometry is superior in many respects including resolution, specificity, multiplex capability and has the ability to measure analytes in various matrices. Despite these advantages, LC-MS/MS remains high cost, labor intensive and has limited throughput. This specialized technology requires highly trained personnel and therefore has largely been limited to large institutions, academic organizations and reference laboratories. Advances in automation will be paramount to break through this bottleneck and increase its appeal for routine use. This article reviews these challenges, shares perspectives on essential features for LC-MS/MS total automation and proposes a step-wise and incremental approach to achieve total automation through reducing human intervention, increasing throughput and eventually integrating the LC-MS/MS system into the automated clinical laboratory operations. Copyright © 2015 Elsevier B.V. All rights reserved.

  11. [Mass spectrometry in the clinical microbiology laboratory].

    Science.gov (United States)

    Jordana-Lluch, Elena; Martró Català, Elisa; Ausina Ruiz, Vicente

    2012-12-01

    Infectious diseases are still a cause of high mortality and morbidity rates. Current microbiological diagnostic methods are based on culture and phenotypic identification of isolated microorganisms, which can be obtained in about 24-48 h. Given that the microbiological identification is of major importance for patient management, new diagnostic methods are needed in order to detect and identify microorganisms in a timely and accurate manner. Over the last few years, several molecular techniques based on the amplification of microbial nucleic acids have been developed with the aim of reducing the time needed for the identification of the microorganisms involved in different infectious processes. On the other hand, mass spectrometry has emerged as a rapid and consistent alternative to conventional methods for microorganism identification. This review describes the most widely used mass spectrometry technologies -matrix-assisted laser desorption/ionization time-of-flight (MALDI-TOF) and electrospray ionization time-of-flight (ESI-TOF)-, both for protein and nucleic acid analysis, as well as the commercial platforms available. Related publications of most interest in clinical microbiology are also reviewed. Copyright © 2011 Elsevier España, S.L. All rights reserved.

  12. Statistical methods for mass spectrometry-based clinical proteomics

    NARCIS (Netherlands)

    Kakourou, A.

    2018-01-01

    The work presented in this thesis focuses on methods for the construction of diagnostic rules based on clinical mass spectrometry proteomic data. Mass spectrometry has become one of the key technologies for jointly measuring the expression of thousands of proteins in biological samples.

  13. Time domain optical spectrometry with fiber optic waveguides

    International Nuclear Information System (INIS)

    Whitten, W.B.

    1983-01-01

    Spectrometers which use optical fibers to obtain time domain spectral dispersion are reviewed. Pulse transmission through fiber optic waveguides is discussed and the basic requirements for sources and detectors are given. Multiplex spectrometry and time-of-flight spectrometry are then discussed. Resolution, fiber requirements, instrumentation and specific spectrometers are presented

  14. High-efficiency thermal ionization sources for mass spectrometry

    International Nuclear Information System (INIS)

    Olivares, Jose A.

    1996-01-01

    A version of the thermal ionization cavity (TIC) source developed specifically for use in mass spectrometry is presented. The performance of this ion source has been characterized extensively both with the use of an isotope separator and a quadrupole mass spectrometer. A detailed description of the TIC source for mass spectrometry is given along with the performance characteristics observed

  15. Applications of accelerator mass spectrometry to nuclear physics and astrophysics

    International Nuclear Information System (INIS)

    Guo Zhiyu; Zhang Chuan

    2002-01-01

    As an ultra high sensitive analyzing method, accelerator mass spectrometry is playing an important role in the studies of nuclear physics and astrophysics. The accelerator mass spectrometry (AMS) applications in searching for violation of Pauli exclusion principle and study on supernovae are discussed as examples

  16. Analysis of posttranslational modifications of proteins by tandem mass spectrometry

    DEFF Research Database (Denmark)

    Larsen, Martin Røssel; Trelle, Morten B; Thingholm, Tine E

    2006-01-01

    -temporal distribution in cells and tissues. Most PTMs can be detected by protein and peptide analysis by mass spectrometry (MS), either as a mass increment or a mass deficit relative to the nascent unmodified protein. Tandem mass spectrometry (MS/MS) provides a series of analytical features that are highly useful...

  17. New developments in glow discharge optical emission and mass spectrometry

    International Nuclear Information System (INIS)

    Hoffmann, Volker; Dorka, Roland; Wilken, Ludger; Wetzig, Klaus

    2000-01-01

    This paper describes new developments in flow discharge optical emission (GD-OES) and mass spectrometry (GD-MS) at IFW and presents corresponding new applications (analysis of microelectronic multi-layer system by radio frequency glow discharge optical emission spectrometry (RF-GD-OES) and analysis of pure iron by a new Grimm-type GD-MS source)

  18. Atomic Absorption, Atomic Fluorescence, and Flame Emission Spectrometry.

    Science.gov (United States)

    Horlick, Gary

    1984-01-01

    This review is presented in six sections. Sections focus on literature related to: (1) developments in instrumentation, measurement techniques, and procedures; (2) performance studies of flames and electrothermal atomizers; (3) applications of atomic absorption spectrometry; (4) analytical comparisons; (5) atomic fluorescence spectrometry; and (6)…

  19. Mass spectrometry for real-time quantitative breath analysis

    Czech Academy of Sciences Publication Activity Database

    Smith, D.; Španěl, Patrik; Herbig, J.; Beauchamp, J.

    2014-01-01

    Roč. 8, č. 2 (2014), 027101 ISSN 1752-7155 Institutional support: RVO:61388955 Keywords : breath analysis * proton transfer reaction mass spectrometry * selected ion flow tube mass spectrometry Subject RIV: CF - Physical ; Theoretical Chemistry Impact factor: 4.631, year: 2014

  20. Reliability of graphite furnace atomic absorption spectrometry as ...

    African Journals Online (AJOL)

    Purpose: To evaluate the comparative efficiency of graphite furnace atomic absorption spectrometry (GFAAS) and hydride generation atomic absorption spectrometry (HGAAS) for trace analysis of arsenic (As) in natural herbal products (NHPs). Method: Arsenic analysis in natural herbal products and standard reference ...

  1. X-ray spectrometry for preventive conservation of cultural heritage

    Indian Academy of Sciences (India)

    Analytical chemistry does play a key role in the chemical characterization of the environment and it appears that X-ray spectrometry, in its many forms, is one of the most relevant analytical techniques in preventive conservation, as it is in cultural heritage research in general. X-ray spectrometry has indeed been the method ...

  2. Cs+ ion source for secondary ion mass spectrometry

    International Nuclear Information System (INIS)

    Bentz, B.L.; Weiss, H.; Liebl, H.

    1981-12-01

    Various types of cesium ionization sources currently used in secondary ion mass spectrometry are briefly reviewed, followed by a description of the design and performance of a novel, thermal surface ionization Cs + source developed in this laboratory. The source was evaluated for secondary ion mass spectrometry applications using the COALA ion microprobe mass analyzer. (orig.)

  3. Probing the Composition, Assembly and Activity of Protein Molecular Machines using Native Mass Spectrometry

    NARCIS (Netherlands)

    van de Waterbeemd, M.J.

    2017-01-01

    Native mass spectrometry and mass spectrometry in general, are powerful analytical tools for studying proteins and protein complexes. Native mass spectrometry may provide accurate mass measurements of large macromolecular assemblies enabling the investigation of their composition and stoichiometry.

  4. Surface ionization mass spectrometry of opiates

    International Nuclear Information System (INIS)

    Usmanov, D.T.

    2009-07-01

    Key words: surface ionization, adsorption, heterogeneous reactions, surface ionization mass spectrometry, thermodesorption surface ionization spectroscopy, thermoemitter, opiates, extracts of biosamples. Subjects of study. The mass - spectrometric study of thermal - ion emission: surface ionization of opiates by on the surface of oxidized refractory metals. Purpose of work is to establish the regularities of surface ionization (SI) of multi-atomic molecule opiates and their mixtures develop the scientific base of SI methods for high sensitive and selective detection and analysis of these substances in the different objects, including biosamples. Methods of study: surface ionization mass spectrometry, thermodesorption surface ionization spectroscopy. The results obtained and their novelty. For the first time, SI of molecule opiates on the oxidized tungsten surface has been studied and their SI mass-spectra and temperature dependences of ion currents have been obtained, the characteristic heterogeneous reactions of an adsorbed molecules and the channels of monomolecular decays vibrationally-excited ions on their way in mass-spectrometry have been revealed, sublimation energy has been defined, the activation energy of E act , of these decays has been estimated for given period of time. Additivity of the SI mass-spectra of opiate mixtures of has been established under conditions of joint opiate adsorption. High selectivity of SI allows the extracts of biosamples to be analyzed without their preliminary chromatographic separation. The opiates are ionized by SI with high efficiency (from 34 C/mol to 112 C/mol), which provides high sensitivity of opiate detection by SI/MS and APTDSIS methods from - 10 -11 g in the samples under analysis. Practical value. The results of these studies create the scientific base for novel SI methods of high sensitive detection and analysis of the trace amounts of opiates in complicated mixtures, including biosamples without their preliminary

  5. Characterizing the lipid and metabolite changes associated with placental function and pregnancy complications using ion mobility spectrometry-mass spectrometry and mass spectrometry imaging

    Energy Technology Data Exchange (ETDEWEB)

    Burnum-Johnson, Kristin E.; Baker, Erin S.; Metz, Thomas O.

    2017-12-01

    Successful pregnancy is dependent upon discrete biological events, which include embryo implantation, decidualization, and placentation. Problems associated with each of these events can cause infertility or conditions such as preeclampsia. A greater understanding of the molecular changes associated with these complex processes is necessary to aid in identifying treatments for each condition. Previous nuclear magnetic resonance spectroscopy and mass spectrometry studies have been used to identify metabolites and lipids associated with pregnancy-related complications. However, due to limitations associated with conventional implementations of both techniques, novel technology developments are needed to more fully understand the initiation and development of pregnancy related problems at the molecular level. In this perspective, we describe current analytical techniques for metabolomic and lipidomic characterization of pregnancy complications and discuss the potential for new technologies such as ion mobility spectrometry-mass spectrometry and mass spectrometry imaging to contribute to a better understanding of the molecular changes that affect the placenta and pregnancy outcomes.

  6. Clinical Mass Spectrometry: Achieving Prominence in Laboratory Medicine

    Energy Technology Data Exchange (ETDEWEB)

    Annesley, Thomas M.; Cooks, Robert G.; Herold, David A.; Hoofnagle, Andrew N.

    2016-01-04

    Each year the journal Clinical Chemistry publishes a January special issue on a topic that is relevant to the laboratory medicine community. In January 2016 the topic is mass spectrometry, and the issue is entitled “Clinical Mass Spectrometry: Achieving Prominence in Laboratory Medicine”. One popular feature in our issues is a Q&A on a topic, clearly in this case mass spectrometry. The journal is assembling a panel of 5-6 experts from various areas of mass spectrometry ranging from instrument manufacturing to practicing clinical chemists. Dick Smith is one of the scientist requested to participate in this special issue Q&A on Mass Spectrometry. The Q&A Transcript is attached

  7. Uncovering biologically significant lipid isomers with liquid chromatography, ion mobility spectrometry and mass spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Kyle, Jennifer E.; Zhang, Xing; Weitz, Karl K.; Monroe, Matthew E.; Ibrahim, Yehia M.; Moore, Ronald J.; Cha, Jeeyeon; Sun, Xiaofei; Lovelace, Erica S.; Wagoner, Jessica; Polyak, Steve; Metz, Thomas O.; Dey, Sudhansu K.; Smith, Richard D.; Burnum-Johnson, Kristin E.; Baker, Erin Shammel

    2016-01-01

    Understanding how biological molecules are generated, metabolized and eliminated in living systems is important for interpreting processes such as immune response and disease pathology. While genomic and proteomic studies have provided vast amounts of information over the last several decades, interest in lipidomics has also grown due to improved analytical technologies revealing altered lipid metabolism in type 2 diabetes, cancer, and lipid storage disease. Liquid chromatography and mass spectrometry (LC-MS) measurements are currently the dominant approach for characterizing the lipidome by providing detailed information on the spatial and temporal composition of lipids. However, interpreting lipids’ biological roles is challenging due to the existence of numerous structural and stereoisomers (i.e. distinct acyl chain and double-bond positions), which are unresolvable using present LC-MS approaches. Here we show that combining structurally-based ion mobility spectrometry (IMS) with LC-MS measurements distinguishes lipid isomers and allows insight into biological and disease processes.

  8. High-field asymmetric waveform ion mobility spectrometry for mass spectrometry-based proteomics.

    Science.gov (United States)

    Swearingen, Kristian E; Moritz, Robert L

    2012-10-01

    High-field asymmetric waveform ion mobility spectrometry (FAIMS) is an atmospheric pressure ion mobility technique that separates gas-phase ions by their behavior in strong and weak electric fields. FAIMS is easily interfaced with electrospray ionization and has been implemented as an additional separation mode between liquid chromatography (LC) and mass spectrometry (MS) in proteomic studies. FAIMS separation is orthogonal to both LC and MS and is used as a means of on-line fractionation to improve the detection of peptides in complex samples. FAIMS improves dynamic range and concomitantly the detection limits of ions by filtering out chemical noise. FAIMS can also be used to remove interfering ion species and to select peptide charge states optimal for identification by tandem MS. Here, the authors review recent developments in LC-FAIMS-MS and its application to MS-based proteomics.

  9. Contribution of photoelectron spectrometry and infrared spectrometry to the study of various oxidised forms of chromium

    International Nuclear Information System (INIS)

    Feve, L.

    1985-03-01

    Securate knowledge of internal surface of primary coolant circuits of PWR is required for an estimation of dissolution of used materials and for estimation of decontamination efficiency. The binding energies of various electron levels of chromium were determined by photoelectron spectrometry (ESCA), both for the metal and for certain compounds. Because of the intensities of the signals obtained the 2 p 3/2 level alone can be used for analytical purposes. Owing to a possible interference between this level due to hexavalent chromium and a satellite peak caused by trivalent chromium the method is not able to show up small amounts of chromium VI in chromium III. Simultaneous detection of the hexavalent and trivalent forms was achieved by infrared spectrometry. The problem of revealing traces of chromium VI in surface layers of trivalent chromium oxide has thus been solved [fr

  10. Programmer for automatic gamma spectrometry; Ordonnateur de sequence pour spectrometrie gamma automatique

    Energy Technology Data Exchange (ETDEWEB)

    Romanetti, R [Commissariat a l' Energie Atomique, Cadarache (France). Centre d' Etudes Nucleaires

    1968-04-01

    With this apparatus, which is constructed of logical integrated circuits, it is possible both to synchronize an automatic gamma spectrometry assembly and to record the spectra on punched cards. An IBM terminal will make it possible with the help of analysis by the least squares method and by a direct dialogue with an IBM 360 computer to obtain analytical results almost instantaneously. (author) [French] Cet appareil, realise en circuits integres logiques, permet d'une part de synchroniser un ensemble automatique de spectrometrie gamma et d'autre part d'enregistrer les spectres sur cartes perforees. Un terminal IBM permettra, a l'aide d'un programme d'analyse par la methode des moindres carres et par un dialogue direct avec un ordinateur IBM 360, de disposer presque intanstanement des resultats des analyses. (auteur)

  11. High Field Asymmetric Waveform Ion Mobility Spectrometry (FAIMS) for Mass Spectrometry-Based Proteomics

    Science.gov (United States)

    Swearingen, Kristian E.; Moritz, Robert L.

    2013-01-01

    SUMMARY High field asymmetric waveform ion mobility spectrometry (FAIMS) is an atmospheric pressure ion mobility technique that separates gas-phase ions by their behavior in strong and weak electric fields. FAIMS is easily interfaced with electrospray ionization and has been implemented as an additional separation mode between liquid chromatography (LC) and mass spectrometry (MS) in proteomic studies. FAIMS separation is orthogonal to both LC and MS and is used as a means of on-line fractionation to improve detection of peptides in complex samples. FAIMS improves dynamic range and concomitantly the detection limits of ions by filtering out chemical noise. FAIMS can also be used to remove interfering ion species and to select peptide charge states optimal for identification by tandem MS. Here, we review recent developments in LC-FAIMS-MS and its application to MS-based proteomics. PMID:23194268

  12. Modulation Spectrometry Of Neutrons With Diffractometry Applications

    International Nuclear Information System (INIS)

    Hiismaki, P.

    1997-01-01

    Modulation spectrometry of neutrons refers to a measuring principle, characterized by classification of neutron histories in a probabilistic way, not the usual deterministic way. In order to accomplish this, neutron beams entering the sample are modulated by high-transmission, white-beam selectors of the multislit type, such as Fourier or statistical choppers or high-frequency-modulated spin-flippers. In this scheme it is impossible to decide in a unique way through which particular slit any single neutron passed, but the distribution of histories for a large population of neutrons can nevertheless be correctly obtained, by classifying each conceivable history either as a high-probability or as a low-probability event,based on the actual observed state of the neutron selector. So far the principle has been successfully applied to powder diffraction, but it seems to offer extra degrees of freedom if applied to measuring dispersion curves of coherent excitations, such as phonons in single crystals

  13. Low Cost silicon photodiodes for alpha spectrometry

    International Nuclear Information System (INIS)

    Khoury, H.; Lopes, A.; Hazin, C.; Lira, C.B.; Silva, E. da

    1998-01-01

    This study was carried out to evaluate the suitability of using commercially available photodiodes for alpha spectrometry, since the principle on which both operate are similar. Photodiodes are low priced compared to the commonly used semiconductor detectors making them potentially useful for research and teaching purposes. Very thin calibrated alpha sources of 2 41 A m, 2 44 C m and 2 35 U , produced at the Metrology Laboratory of IRD/CNEN, were used to test the performance of three photodiodes. The results showed that the responses of the photodiodes were linear with the alpha particle energy and that the energy resolution varied between 0,79% and 0,45%, with an efficiency of 8%. The resolution and efficiency presented by the photodiodes tested are similar to those obtained with other semiconductor detectors, evidencing that they can be used successfully as alpha detectors

  14. New possibilities in prompt gamma ray spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Borderie, B; Barrandon, J N [Centre National de la Recherche Scientifique, 45 - Orleans-la-Source (France). Lab. du cyclotron; Pinault, J L [Bureau de Recherches Geologiques et Minieres (BRGM), 45 - Orleans (France)

    1977-01-01

    Prompt gamma ray spectrometry has been used as an analytical tool for many years. The high level of background noise does, however, remain a major problem with this technique. From simple theoretical consideration, conditions (particle, energy) were determined to reduce significantly the background noise under irradiation. Alpha particles of 3.5 MeV were chosen. Some fifty elements were studied, of which 24 gave interesting results. The detection limits obtained for a sample of niobium were as follows: approximately 1 ppm (10/sup -6/g/g) for the light elements Li, B, F and Na, and between 50 ppm and 1% for the others. Numerous applications may be envisaged in the geo- and cosmo-sciences.

  15. Computational mass spectrometry for small molecules

    Science.gov (United States)

    2013-01-01

    The identification of small molecules from mass spectrometry (MS) data remains a major challenge in the interpretation of MS data. This review covers the computational aspects of identifying small molecules, from the identification of a compound searching a reference spectral library, to the structural elucidation of unknowns. In detail, we describe the basic principles and pitfalls of searching mass spectral reference libraries. Determining the molecular formula of the compound can serve as a basis for subsequent structural elucidation; consequently, we cover different methods for molecular formula identification, focussing on isotope pattern analysis. We then discuss automated methods to deal with mass spectra of compounds that are not present in spectral libraries, and provide an insight into de novo analysis of fragmentation spectra using fragmentation trees. In addition, this review shortly covers the reconstruction of metabolic networks using MS data. Finally, we list available software for different steps of the analysis pipeline. PMID:23453222

  16. Inductively coupled plasma source mass spectrometry

    International Nuclear Information System (INIS)

    Price Russ, G. III

    1993-01-01

    Inductively coupled plasma source mass spectrometry (ICP-MS) is a relatively new (5 y commercial availability) technique for simultaneously determining the concentration and isotopic composition of a large number of elements at trace levels. The principle advantages of ICP-MS are the ability to measure essentially all the metallic elements at concentrations as low as 1 part in 10 12 by weight, to analyse aqueous samples directly, to determine the isotopic composition of essentially all the metallic elements, and to analyse samples rapidly (minutes). The history of the development of ICP-MS and discussions of a variety of applications have been discussed in detail in Date and Gray (1988). Koppenaal (1988, 1990) has reviewed the ICP-MS literature. In that ICP-MS is a relatively new and still evolving technique, this chapter will discuss potential capability more than proven performance. (author). 24 refs

  17. Recent development in isotope ratio mass spectrometry

    International Nuclear Information System (INIS)

    Platzner, I.

    1992-01-01

    Within the limited of this review the following topics will be briefly discussed: a) Accuracy, precision, internal relative standard deviation (RISD) and external relative standard deviation (RESD) of isotope ratio measurements. With advanced instrumentation and use of standard reference materials, high accuracy and RESD = 0.002% (or better) may be achieved; b) The advantages of modern automatic isotope ratio mass spectrometer are briefly described. Computer controlled operation and data acquisition, and multiple ion collection are the recent important improvement; c) The isotopic fractionation during the course of isotope ratio measurement is considered as a major source of errors in thermal ionization of metallic elements. The phenomenon in strontium, neodymium, uranium, lead and calcium and methods to correct the measured data are discussed; d) Applications of isotope ratio mass spectrometry in atomic weight determinations, the isotope dilution technique, isotope geology, and isotope effects in biological systems are described together with specific applications in various research and technology area. (author)

  18. Method and apparatuses for ion cyclotron spectrometry

    Science.gov (United States)

    Dahl, David A [Idaho Falls, ID; Scott, Jill R [Idaho Falls, ID; McJunkin, Timothy R [Idaho Falls, ID

    2012-03-06

    An ion cyclotron spectrometer may include a vacuum chamber that extends at least along a z-axis and means for producing a magnetic field within the vacuum chamber so that a magnetic field vector is generally parallel to the z-axis. The ion cyclotron spectrometer may also include means for producing a trapping electric field within the vacuum chamber. The trapping electric field may comprise a field potential that, when taken in cross-section along the z-axis, includes at least one section that is concave down and at least one section that is concave up so that ions traversing the field potential experience a net magnetron effect on a cyclotron frequency of the ions that is substantially equal to zero. Other apparatuses and a method for performing ion cyclotron spectrometry are also disclosed herein.

  19. Application of Nanodiamonds in Biomolecular Mass Spectrometry

    Directory of Open Access Journals (Sweden)

    Ping Cheng

    2010-03-01

    Full Text Available The combination of nanodiamond (ND with biomolecular mass spectrometry (MS makes rapid, sensitive detection of biopolymers from complex biosamples feasible. Due to its chemical inertness, optical transparency and biocompatibility, the advantage of NDs in MS study is unique. Furthermore, functionalization on the surfaces of NDs expands their application in the fields of proteomics and genomics for specific requirements greatly. This review presents methods of MS analysis based on solid phase extraction and elution on NDs and different application examples including peptide, protein, DNA, glycan and others. Owing to the quick development of nanotechnology, surface chemistry, new MS methods and the intense interest in proteomics and genomics, a huge increase of their applications in biomolecular MS analysis in the near future can be predicted.

  20. [Application of mass spectrometry in mycology].

    Science.gov (United States)

    Quiles Melero, Inmaculada; Peláez, Teresa; Rezusta López, Antonio; Garcia-Rodríguez, Julio

    2016-06-01

    MALDI-TOF (matrix-assisted laser desorption ionization time-of-flight) mass spectrometry (MS) is becoming an essential tool in most microbiology laboratories. At present, by using a characteristic fungal profile obtained from whole cells or through simple extraction protocols, MALDI-TOF MS allows the identification of pathogenic fungi with a high performance potential. This methodology decreases the laboratory turnaround time, optimizing the detection of mycoses. This article describes the state-of-the-art of the use of MALDI-TOF MS for the detection of human clinical fungal pathogens in the laboratory and discusses the future applications of this technology, which will further improve routine mycological diagnosis. Copyright © 2016 Elsevier España, S.L.U. All rights reserved.

  1. Radiocarbon positive-ion mass spectrometry

    International Nuclear Information System (INIS)

    Freeman, Stewart P.H.T.; Shanks, Richard P.; Donzel, Xavier; Gaubert, Gabriel

    2015-01-01

    Proof-of-principle of a new mass spectrometric technique for radiocarbon measurement is demonstrated. Interfering nitrogen and hydrocarbon molecules are largely eliminated in a charge-exchange cell operating on non-metallic gas. The positive-to-negative ion conversion is the reverse of that conventionally used in accelerator mass spectrometry (AMS) and is compatible with plasma ion sources that may be significantly more efficient and capable of greater output than are AMS sputter ion sources. The Nanogan electron cyclotron resonance (ECR) ion source employed exhibited no sample memory and the >50 kyrs age range of AMS was reproduced. A bespoke prototype new instrument is now required to optimise the plasma and cell physics and to realise hypothetical performance gains over AMS.

  2. Liulin-type spectrometry-dosimetry instruments

    International Nuclear Information System (INIS)

    Dachev, T.; Dimitrov, P.; Tomov, B.; Matviichuk, Y.; Spurny, F.; Ploc, O.; Brabcova, K.; Jadrnickova, I.

    2011-01-01

    The main purpose of Liulin-type spectrometry-dosimetry instruments (LSDIs) is cosmic radiation monitoring at the workplaces. An LSDI functionally is a low mass, low power consumption or battery-operated dosemeter. LSDIs were calibrated in a wide range of radiation fields, including radiation sources, proton and heavy-ion accelerators and CERN-EC high-energy reference field. Since 2000, LSDIs have been used in the scientific programmes of four manned space flights on the American Laboratory and ESA Columbus modules and on the Russian segment of the International Space Station, one Moon spacecraft and three spacecraft around the Earth, one rocket, two balloons and many aircraft flights. In addition to relative low price, LSDIs have proved their ability to qualify the radiation field on the ground and on the above-mentioned carriers. (authors)

  3. Radiocarbon positive-ion mass spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Freeman, Stewart P.H.T.; Shanks, Richard P. [Scottish Universities Environmental Research Centre (SUERC), Scottish Enterprise Technology Park, East Kilbride G75 0QF (United Kingdom); Donzel, Xavier; Gaubert, Gabriel [Pantechnik S.A., 13 Rue de la Résistance, 14400 Bayeux (France)

    2015-10-15

    Proof-of-principle of a new mass spectrometric technique for radiocarbon measurement is demonstrated. Interfering nitrogen and hydrocarbon molecules are largely eliminated in a charge-exchange cell operating on non-metallic gas. The positive-to-negative ion conversion is the reverse of that conventionally used in accelerator mass spectrometry (AMS) and is compatible with plasma ion sources that may be significantly more efficient and capable of greater output than are AMS sputter ion sources. The Nanogan electron cyclotron resonance (ECR) ion source employed exhibited no sample memory and the >50 kyrs age range of AMS was reproduced. A bespoke prototype new instrument is now required to optimise the plasma and cell physics and to realise hypothetical performance gains over AMS.

  4. Calibration samples for accelerator mass spectrometry

    International Nuclear Information System (INIS)

    Hershberger, R.L.; Flynn, D.S.; Gabbard, F.

    1981-01-01

    Radioactive samples with precisely known numbers of atoms are useful as calibration sources for lifetime measurements using accelerator mass spectrometry. Such samples can be obtained in two ways: either by measuring the production rate as the sample is created or by measuring the decay rate after the sample has been obtained. The latter method requires that a large sample be produced and that the decay constant be accurately known. The former method is a useful and independent alternative, especially when the decay constant is not well known. The facilities at the University of Kentucky for precision measurements of total neutron production cross sections offer a source of such calibration samples. The possibilities, while quite extensive, would be limited to the proton rich side of the line of stability because of the use of (p,n) and (α,n) reactions for sample production

  5. Subattomole sensitivity in biological accelerator mass spectrometry.

    Science.gov (United States)

    Salehpour, Mehran; Possnert, Göran; Bryhni, Helge

    2008-05-15

    The Uppsala University 5 MV Pelletron tandem accelerator has been used to study (14)C-labeled biological samples utilizing accelerator mass spectrometry (AMS) technology. We have adapted a sample preparation method for small biological samples down to a few tens of micrograms of carbon, involving among others, miniaturizing of the graphitization reactor. Standard AMS requires about 1 mg of carbon with a limit of quantitation of about 10 amol. Results are presented for a range of small sample sizes with concentrations down to below 1 pM of a pharmaceutical substance in human blood. It is shown that (14)C-labeled molecular markers can be routinely measured from the femtomole range down to a few hundred zeptomole (10 (-21) mol), without the use of any additional separation methods.

  6. Low level processing of diode spectrometry results

    International Nuclear Information System (INIS)

    Philippot, J.C.

    1975-01-01

    Systematic measurements in gamma spectrometry on slightly radioactive samples have led to study low levels existing in the spectra and to develop suitable processing methods. These methods and the advance that they represent in reading sensitivity are now applicable to all types of spectrum. The principles of this automatic reading are briefly summarized, leading to a description of the modifications which proved necessary to increase sensitivity. Three sample spectra are used to illustrate the arguments employed to achieve this result. The conclusions from the corresponding measurements provide a clearer understanding of the quality of the responses obtained during the initial reading. The application of these methods to systematic measurements is considered in the case of atmospheric aerosols. The owerall results obtained since 1969 are presented [fr

  7. Neutron Spectrometry for Radiation Protection Purposes

    International Nuclear Information System (INIS)

    McDonald, Joseph C.

    2001-01-01

    Determination of the dose equivalent is required for radiation protection purposes, however such a determination is quite difficult for neutron radiation. In order to perform accurate dosimetric determinations, it is necessary to acquire information about the neutron fluence spectrum in the workplace as well as the reference radiations used to calibrate dosimetric instruments. This information can then be used to select the appropriate dosimetric instrument, the optimum calibration condition or to establish correction factors that account for the differences in calibration and workplace conditions. For quite some time, neutron spectrometry has been used for these purposes. A brief review of the applications of spectrometers in radiation protection and some recommendations for further development are given here

  8. Neutron spectrometry for radiation protection purposes

    CERN Document Server

    McDonald, J C; Alberts, W G

    2002-01-01

    Determination of the dose equivalent is required for radiation protection purposes, however such a determination is quite difficult for neutron radiation. In order to perform accurate dosimetric determinations, it is advantageous to acquire information about the neutron fluence spectrum in the workplace as well as the reference radiations used to calibrate dosimetric instruments. This information can then be used to select the appropriate dosimetric instrument, the optimum calibration condition or to establish correction factors that account for the differences in calibration and workplace conditions. For quite some time, neutron spectrometry has been used for these purposes. A brief review of the applications of spectrometers in radiation protection and some recommendations for further development are given here.

  9. Radiocarbon dating with accelerator mass spectrometry

    International Nuclear Information System (INIS)

    Blake, W. Jr.

    1985-01-01

    Radiocarbon dating by means of accelerator mass spectrometry (AMS) has two great advantages over conventional dating: 1) much smaller samples can be handled and 2) counting time is significantly shorter. Three examples are given for Holocene-age material from east-central Ellesmere Island. The results demonstrate the potential use of this technique as a powerful research tool in studies of Quaternary chronology. Individual fragments of marine shells as small as 0.1 g have been dated successfully at the IsoTrace Laboratory, University of Toronto. In the case of an aquatic moss from a lake sediment core, an increment 0.5 cm thick could be used instead of a 5 cm-thick slice, thus allowing a much more precise estimate of the onset of organic sedimentation

  10. Analysis of barium by isotope mass spectrometry

    International Nuclear Information System (INIS)

    Long Kaiming; Jia Baoting; Liu Xuemei

    2004-01-01

    The isotopic abundance ratios for barium at sub-microgram level are analyzed by thermal surface ionization mass spectrometry (TIMS). Rhenium trips used for sample preparation are firstly treated to eliminate possible barium background interference. During the preparation of barium samples phosphoric acid is added as an emitting and stabilizing reagent. The addition of phosphoric acid increases the collection efficiency and ion current strength and stability for barium. A relative standard deviation of 0.02% for the isotopic abundance ratio of 137 Ba to 138 Ba is achieved when the 138 Ba ion current is (1-3) x 10 -12 A. The experimental results also demonstrate that the isotope fractionation effect is negligibly small in the isotopic analysis of barium

  11. Intercomparison of alpha particle spectrometry software packages

    International Nuclear Information System (INIS)

    1999-08-01

    Software has reached an important level as the 'logical controller' at different levels, from a single instrument to an entire computer-controlled experiment. This is also the case for software packages in nuclear instruments and experiments. In particular, because of the range of applications of alpha-particle spectrometry, software packages in this field are often used. It is the aim of this intercomparison to test and describe the abilities of four such software packages. The main objectives of the intercomparison were the ability of the programs to determine the peak areas and the peak area uncertainties, and the statistical control and stability of reported results. In this report, the task, methods and results of the intercomparison are presented in order to asist the potential users of such software and to stimulate the development of even better alpha-particle spectrum analysis software

  12. Composite mapping experiences in airborne gamma spectrometry

    International Nuclear Information System (INIS)

    Bucher, B.

    2014-01-01

    During an international intercomparison exercise of airborne gamma spectrometry held in Switzerland 2007 teams from Germany, France and Switzerland were proving their capabilities. One of the tasks was the composite mapping of an area around Basel. Each team was mainly covering the part of its own country at its own flying procedures. They delivered the evaluated data in a data format agreed in advance. The quantities to be delivered were also defined in advance. Nevertheless, during the process to put the data together a few questions raised: Which dose rate was meant? Had the dose rate to be delivered with or without cosmic contribution? Activity per dry or wet mass? Which coordinate system was used? Finally, the data could be put together in one map. For working procedures in case of an emergency, quantities of interest and exchange data format have to be defined in advance. But the procedures have also to be proved regularly. (author)

  13. Enantioselectivity of mass spectrometry: challenges and promises.

    Science.gov (United States)

    Awad, Hanan; El-Aneed, Anas

    2013-01-01

    With the fast growing market of pure enantiomer drugs and bioactive molecules, new chiral-selective analytical tools have been instigated including the use of mass spectrometry (MS). Even though MS is one of the best analytical tools that has efficiently been used in several pharmaceutical and biological applications, traditionally MS is considered as a "chiral-blind" technique. This limitation is due to the MS inability to differentiate between two enantiomers of a chiral molecule based merely on their masses. Several approaches have been explored to assess the potential role of MS in chiral analysis. The first approach depends on the use of MS-hyphenated techniques utilizing fast and sensitive chiral separation tools such as liquid chromatography (LC), gas chromatography (GC), and capillary electrophoresis (CE) coupled to MS detector. More recently, several alternative separation techniques have been evaluated such as supercritical fluid chromatography (SFC) and capillary electrochromatography (CEC); the latter being a hybrid technique that combines the efficiency of CE with the selectivity of LC. The second approach is based on using the MS instrument solely for the chiral recognition. This method depends on the behavioral differences between enantiomers towards a foreign molecule and the ability of MS to monitor such differences. These behavioral differences can be divided into three types: (i) differences in the enantiomeric affinity for association with the chiral selector, (ii) differences of the enantiomeric exchange rate with a foreign reagent, and (iii) differences in the complex MS dissociation behaviors of the enantiomers. Most recently, ion mobility spectrometry was introduced to qualitatively and quantitatively evaluate chiral compounds. This article provides an overview of MS role in chiral analysis by discussing MS based methodologies and presenting the challenges and promises associated with each approach. © 2013 Wiley Periodicals, Inc.

  14. Imaging mass spectrometry in drug development and toxicology.

    Science.gov (United States)

    Karlsson, Oskar; Hanrieder, Jörg

    2017-06-01

    During the last decades, imaging mass spectrometry has gained significant relevance in biomedical research. Recent advances in imaging mass spectrometry have paved the way for in situ studies on drug development, metabolism and toxicology. In contrast to whole-body autoradiography that images the localization of radiolabeled compounds, imaging mass spectrometry provides the possibility to simultaneously determine the discrete tissue distribution of the parent compound and its metabolites. In addition, imaging mass spectrometry features high molecular specificity and allows comprehensive, multiplexed detection and localization of hundreds of proteins, peptides and lipids directly in tissues. Toxicologists traditionally screen for adverse findings by histopathological examination. However, studies of the molecular and cellular processes underpinning toxicological and pathologic findings induced by candidate drugs or toxins are important to reach a mechanistic understanding and an effective risk assessment strategy. One of IMS strengths is the ability to directly overlay the molecular information from the mass spectrometric analysis with the tissue section and allow correlative comparisons of molecular and histologic information. Imaging mass spectrometry could therefore be a powerful tool for omics profiling of pharmacological/toxicological effects of drug candidates and toxicants in discrete tissue regions. The aim of the present review is to provide an overview of imaging mass spectrometry, with particular focus on MALDI imaging mass spectrometry, and its use in drug development and toxicology in general.

  15. Mass Spectrometry for Large Undergraduate Laboratory Sections

    Science.gov (United States)

    Illies, A.; Shevlin, P. B.; Childers, G.; Peschke, M.; Tsai, J.

    1995-08-01

    Mass spectrometry is routinely covered in undergraduate organic chemistry courses and a number of valuable laboratory experiments featuring its use have been discussed (1-7). Although such experiments work well at institutions with limited laboratory enrollments, we typically teach laboratories with enrollments of 160 or more in which it is difficult to allow each student to carry out a meaningful "hands on" mass spectrometry experiment. Since we feel that some practical experience with this technique is important, we have designed a simple gas chromatography-mass spectrometry (gc/ms) exercise that allows each student to analyze the products of a simple synthesis that they have performed. The exercise starts with the microscale SN2 synthesis of 1-bromobutane from 1-butanol as described by Williamson (8). The students complete the synthesis and place one drop of the distilled product in a screw capped vial. The vials are then sealed, labeled with the students name and taken to the mass spectrometry laboratory by a teaching assistant. Students are instructed to sign up for a 20-min block of time over the next few days in order to analyze their sample. When the student arrives at the laboratory, he or she adds 1 ml CH2Cl2 to the sample and injects 0.3 microliters of the solution into the gas chromatograph. The samples typically contain the 1-butanol starting material and the 1-bromobutane product along with traces of dibutyl ether. The figure shows a mass chromatogram along with the mass spectra of the starting material and product from an actual student run. For this analysis to be applicable to large numbers of students, the gc separation must be as rapid as possible. We have been able to analyze each sample in 6 minutes on a 30 m DB-5 capillary column with the following temperature program: 70 oC for 1 min, 70-80 oC at 10 oC/min, 86-140 oC at 67.5 oC/min, 140-210 oC at 70 oC/min, and 210 oC for 1 min. A mass range of 20-200 amu is scanned with a solvent delay of 2

  16. [Advances in mass spectrometry-based approaches for neuropeptide analysis].

    Science.gov (United States)

    Ji, Qianyue; Ma, Min; Peng, Xin; Jia, Chenxi; Ji, Qianyue

    2017-07-25

    Neuropeptides are an important class of endogenous bioactive substances involved in the function of the nervous system, and connect the brain and other neural and peripheral organs. Mass spectrometry-based neuropeptidomics are designed to study neuropeptides in a large-scale manner and obtain important molecular information to further understand the mechanism of nervous system regulation and the pathogenesis of neurological diseases. This review summarizes the basic strategies for the study of neuropeptides using mass spectrometry, including sample preparation and processing, qualitative and quantitative methods, and mass spectrometry imagining.

  17. Mass spectrometry for characterizing plant cell wall polysaccharides

    Directory of Open Access Journals (Sweden)

    Stefan eBauer

    2012-03-01

    Full Text Available Mass spectrometry is a selective and powerful technique to obtain identification and structural information on compounds present in complex mixtures. Since it requires only small sample amount it is an excellent tool for researchers interested in detecting changes in composition of complex carbohydrates of plants. This mini-review gives an overview of common mass spectrometry techniques applied to the analysis of plant cell wall carbohydrates. It presents examples in which mass spectrometry has been used to elucidate the structure of oligosaccharides derived from hemicelluloses and pectins and illustrates how information on sequence, linkages, branching and modifications are obtained from characteristic fragmentation patterns.

  18. [Latest development in mass spectrometry for clinical application].

    Science.gov (United States)

    Takino, Masahiko

    2013-09-01

    Liquid chromatography-tandem mass spectrometry (LC-MS/MS) has seen enormous growth in special clinical chemistry laboratories. It significantly increases the analytic potential in clinical chemistry, especially in the field of low molecular weight biomarker analysis. This review summarizes the state of the art in mass spectrometry and related techniques for clinical application with a main focus on recent developments in LC-MS. Current trends in ionization techniques, automated online sample preparation techniques coupled with LC-MS, and ion mobility spectrometry are discussed. Emerging mass spectrometric approaches complementary to LC-MS are discussed as well.

  19. Flow injection analysis in inductively coupled plasma spectrometry

    International Nuclear Information System (INIS)

    Rosias, Maria F.G.G.

    1995-10-01

    The main features of flow injection analysis (FIA) as contribution to the inductively coupled plasma (Icp) spectrometry are described. A systematic review of researches using the combined FIA-Icp and the benefits of this association are presented. Flow systems were proposed to perform on-line Icp solution management for multielemental determination by atomic emission spectrometry (Icp-AES) or mass spectrometry. The inclusion of on-line ion exchangers in flow systems for matrix separation and/or analyte preconcentration are presented. Together with those applications the new advent of instruments with facilities for multielement detection on flow injection signals are described. (author). 75 refs., 19 figs

  20. Proteomic Mass Spectrometry Imaging for Skin Cancer Diagnosis.

    Science.gov (United States)

    Lazova, Rossitza; Seeley, Erin H

    2017-10-01

    Mass spectrometry imaging can be successfully used for skin cancer diagnosis, particularly for the diagnosis of challenging melanocytic lesions. This method analyzes proteins within benign and malignant melanocytic tumor cells and, based on their differences, which constitute a unique molecular signature of 5 to 20 proteins, can render a diagnosis of benign nevus versus malignant melanoma. Mass spectrometry imaging may assist in the differentiation between metastases and nevi as well as between proliferative nodules in nevi and melanoma arising in a nevus. In the difficult area of atypical Spitzoid neoplasms, mass spectrometry diagnosis can predict clinical outcome better than histopathology. Copyright © 2017 Elsevier Inc. All rights reserved.

  1. X-ray spectrometry with synchrotron radiation; Roentgenspektrometrie mit Synchrotronstrahlung

    Energy Technology Data Exchange (ETDEWEB)

    Mueller, Matthias [Physikalisch-Technische Bundesanstalt (PTB), Berlin (Germany). Arbeitsgruppe ' Roentgen- und IR-Spektrometrie' ; Gerlach, Martin; Holfelder, Ina; Hoenicke, Philipp; Lubeck, Janin; Nutsch, Andreas; Pollakowski, Beatrix; Streeck, Cornelia; Unterumsberger, Rainer; Weser, Jan; Beckhoff, Burkhard

    2014-12-15

    The X-ray spectrometry of the PTB at the BESSY II storage ring with radiation in the range from 78 eV to 10.5 keV is described. After a description of the instrumentation development reference-sample free X-ray fluorescence analysis, the determination of fundamental atomic parameters, X-ray fluorescence analysis under glance-angle incidence, highly-resolving absorption spectrometry, and emission spectrometry are considered. Finally liquid cells and in-situ measurement techniques are described. (HSI)

  2. Spectral interferences in atomic absorption spectrometry, (5)

    International Nuclear Information System (INIS)

    Daidoji, Hidehiro

    1979-01-01

    Spectral interferences were observed in trace element analysis of concentrated solutions by atomic absorption spectrometry. Molecular absorption and emission spectra for strontium chloride and nitrate, barium chloride and nitrate containing 12 mg/ml of metal ion in airacetylene flame were measured in the wavelength range from 200 to 700 nm. The absorption and emission spectra of SrO were centered near 364.6 nm. The absorption spectra of SrOH around 606.0, 671.0 and 682.0 nm were very strong. And, emission spectrum of BaOH in the wavelength range from 480 to 550 nm was stronger. But, the absorption of this band spectrum was very weak. In the wavelength range from 200 to 400 nm, some unknown bands of absorption were observed for strontium and barium. Absorption spectra of SrCl and BaCl were observed in the argon-hydrogen flame. Also, in the carbon tube atomizer, the absorption spectra of SrCl and BaCl were detected clearly in the wavelength range from 185 to 400 nm. (author)

  3. Ambient ionization mass spectrometry: A tutorial

    Energy Technology Data Exchange (ETDEWEB)

    Huang, Min-Zong; Cheng, Sy-Chi; Cho, Yi-Tzu [Department of Chemistry, National Sun Yat-Sen University, Kaohsiung, Taiwan (China); Shiea, Jentaie, E-mail: jetea@fac.nsysu.edu.tw [Department of Chemistry, National Sun Yat-Sen University, Kaohsiung, Taiwan (China); Cancer Center, Kaohsiung Medical University, Kaohsiung, Taiwan (China)

    2011-09-19

    Highlights: {yields} Ambient ionization technique allows the direct analysis of sample surfaces with little or no sample pretreatment. {yields} We sort ambient ionization techniques into three main analytical strategies, direct ionization, direct desorption/ionization, and two-step ionization. {yields} The underlying principles of operation, ionization processes, detecting mass ranges, sensitivity, and representative applications of these techniques are described and compared. - Abstract: Ambient ionization is a set of mass spectrometric ionization techniques performed under ambient conditions that allows the direct analysis of sample surfaces with little or no sample pretreatment. Using combinations of different types of sample introduction systems and ionization methods, several novel techniques have been developed over the last few years with many applications (e.g., food safety screening; detection of pharmaceuticals and drug abuse; monitoring of environmental pollutants; detection of explosives for antiterrorism and forensics; characterization of biological compounds for proteomics and metabolomics; molecular imaging analysis; and monitoring chemical and biochemical reactions). Electrospray ionization and atmospheric pressure chemical ionization are the two main ionization principles most commonly used in ambient ionization mass spectrometry. This tutorial paper provides a review of the publications related to ambient ionization techniques. We describe and compare the underlying principles of operation, ionization processes, detecting mass ranges, sensitivity, and representative applications of these techniques.

  4. Alpha particle analysis using PEARLS spectrometry

    International Nuclear Information System (INIS)

    McKlveen, J.W.; Klingler, G.W.; McDowell, W.J.; Case, G.N.

    1984-01-01

    Alpha particle assay by conventional plate-counting methods is difficult because chemical separation, tracer techniques, and/or self-absorption losses in the final sample may cause either non-reproducible results or create unacceptable errors. PEARLS (Photon-Electron Rejecting Alpha Liquid Scintillation) Spectrometry is an attractive alternative since radionuclides may be extracted into a scintillator in which there would be no self-absorption or geometry problems and in which up to 100% chemical recovery and counting efficiency is possible. Sample preparation may include extraction of the alpha emitter of interest by a specific organic-phase-soluble compound directly into the liquid scintillator. Detection electronics use energy and pulse-shape discrimination to provide discrete alpha spectra and virtual absence of beta and gamma backgrounds. Backgrounds on the order of 0.01 cpm are readily achievable. Accuracy and reproducibility are typically in the 100 +-1% range. Specific procedures have been developed for gross alpha, uranium, plutonium, thorium, and polonium assay. This paper will review liquid scintillation alpha counting methods and reference some of the specific applications. 8 refs., 1 fig

  5. Secondary Ion Mass Spectrometry SIMS XI

    Science.gov (United States)

    Gillen, G.; Lareau, R.; Bennett, J.; Stevie, F.

    2003-05-01

    This volume contains 252 contributions presented as plenary, invited and contributed poster and oral presentations at the 11th International Conference on Secondary Ion Mass Spectrometry (SIMS XI) held at the Hilton Hotel, Walt Disney World Village, Orlando, Florida, 7 12 September, 1997. The book covers a diverse range of research, reflecting the rapid growth in advanced semiconductor characterization, ultra shallow depth profiling, TOF-SIMS and the new areas in which SIMS techniques are being used, for example in biological sciences and organic surface characterization. Papers are presented under the following categories: Isotopic SIMS Biological SIMS Semiconductor Characterization Techniques and Applications Ultra Shallow Depth Profiling Depth Profiling Fundamental/Modelling and Diffusion Sputter-Induced Topography Fundamentals of Molecular Desorption Organic Materials Practical TOF-SIMS Polyatomic Primary Ions Materials/Surface Analysis Postionization Instrumentation Geological SIMS Imaging Fundamentals of Sputtering Ion Formation and Cluster Formation Quantitative Analysis Environmental/Particle Characterization Related Techniques These proceedings provide an invaluable source of reference for both newcomers to the field and experienced SIMS users.

  6. Liquid chromatography - mass spectrometry analysis of pharmaceuticals

    International Nuclear Information System (INIS)

    Macasek, F.

    2003-01-01

    The drugs represent mostly non-volatile and thermally labile solutes, often available only in small amounts like it is in case of radiopharmaceuticals. Therefor, the favourable separation techniques for such compounds are HPLC, capillary electrophoresis and also TLC 1. Liquid chromatography with mass spectrometric detector (LC/MS) is especially powerful for their microanalysis. Mass spectrometry separating the ions in high vacuum was presumably used as detector for gas chromatography effluent but the on-line coupling with liquid eluant flow 0.1-1 mL/min is far more challenging. New types of ion sources were constructed for simultaneous removal of solvent and ionisation of solutes at atmospheric pressure (API). At present, a relatively wide choice of successfully designed commercial equipment is available either for small organic molecules and larger biomolecules (Perkin-Elmer, Agilent, Jeol, Bruker Daltonics, ThermoQuest, Shimadzu). The features of the LC/MS systems are presented. LC/MS as a new quality control tool for [F-18]fluorodeoxyglucose (FDG) radiopharmaceutical, which has became the most spread radiopharmaceutical for positron emission tomography (PET), was proposed. Other applications of the LC/MS are reviewed. (author)

  7. New applications of accelerator mass spectrometry

    International Nuclear Information System (INIS)

    Davis, J.C.

    1991-01-01

    Since its invention in the late 70's, and reduction to near-routine practice by the mid-80's, accelerator mass spectrometry (AMS) has become a powerful tool for archaeological and geochemical measurements in which cosmogenic isotopes such as 10 Be, 14 C, 26 Al, 36 Cl and 129 I are used as either tracers or chronometers. The utility of such measurements is demonstrated by the fact that most accelerators having AMS capabilities have significant backlogs of samples awaiting measurement. In designing and justifying a new accelerator facility in which AMS was to be a major feature, we sought to advance the field and increase the resources available for it by two steps: (1) development of new research applications in which intentionally added isotopic labels were used rather than just naturally present ones; and (2) enhancement of spectrometer throughout, making new classes of experiments possible by greatly increasing the number of samples that could be measured in individual experiments. Results of the effort to date suggest that development of a family of very small spectrometers optimized for just tritium and/or radiocarbon will be attractive in the near future

  8. Radiocarbon mass spectrometry for drug development

    International Nuclear Information System (INIS)

    Ulrich, Schulze-Konig Tim

    2011-01-01

    Full text: Radiocarbon has a huge potential as a tracer for metabolism studies in humans. By using Accelerator Mass Spectrometry (AMS) for its detection, a unique sensitivity is reached reducing required radiation doses to a negligible level. Until recently, a widespread use of AMS in biomedical research was impeded by the high complexity of the instrument, time-consuming sample preparation, and a limited availability of measurement capacity. Over the last few years, tremendous progress has been achieved in the reduction of size and complexity of AMS instruments. It allowed designing a compact AMS system, dubbed BioMICADAS to address the needs of biomedical users. For more than two years, this system is in successful operation at a commercial service provider for the pharmaceutical industry. A further drastic simplification of radiocarbon mass spectrometers seems possible and could establish a regular usage of this technology in drug development. However, to reach this goal a better integration of AMS into the workflow of bioanalytical laboratories will be necessary. For this purpose, CO 2 accepting ion sources may be a key, since they enable an almost automated sample preparation. The status of radiocarbon AMS in biomedical research and its perspective will be discussed

  9. Accelerator mass spectrometry for radiocarbon dating

    International Nuclear Information System (INIS)

    Bronk, C.R.

    1987-01-01

    Accelerator mass spectrometry (AMS) has been used routinely for radiocarbon measurements for several years. This thesis describes theoretical work to understand the reasons for low accuracy and range and offers practical solutions. The production and transport of the ions used in the measurements are found to be the most crucial stages in the process. The theories behind ion production by sputtering are discussed and applied to the specific case of carbon sputtered by caesium. Experimental evidence is also examined in relation to the theories. The phenomena of space charge and lens aberrations are discussed along with the interaction between ion beams and gas molecules in the vacuum. Computer programs for calculating phase space transformations are then described; these are designed to help investigations of the effects of space charge and aberrations on AMS measurements. Calculations using these programs are discussed in relation both to measured ion beam profiles in phase space and to the current dependent transmission of ions through the Oxford radiocarbon accelerator. Improvements have been made to this accelerator and these are discussed in the context of the calculations. C - ions are produced directly from carbon dioxide at the Middleton High Intensity Sputter Source. Experiments to evaluate the performance of such a source are described and detailed design criteria established. An ion source designed and built specifically for radiocarbon measurements using carbon dioxide is described. Experiments to evaluate its performance and investigate the underlying physical processes are discussed. (author)

  10. 14C Accelerator mass spectrometry in Brazil

    International Nuclear Information System (INIS)

    Macario, K.D.; Gomes, P.R.S.; Anjos, Roberto M.; Linares, R.; Queiroz, E.A.; Oliveira, F.M.; Cardozo, L.; Carvalho, C.R.A.

    2011-01-01

    Radiocarbon Accelerator Mass Spectrometry is an ultra-sensitive technique that enables the direct measurement of carbon isotopes in samples as small as a few milligrams. The possibility of dating or tracing rare or even compound specific carbon samples has application in many fields of science such as Archaeology, Geosciences and Biomedicine. Several kinds of material such as wood, charcoal, carbonate and bone can be chemically treated and converted to graphite to be measured in the accelerator system. The Physics Institute of Universidade Federal Fluminense (UFF), in Brazil will soon be able to perform the complete 14 C-AMS measurement of samples. At the Nuclear Chronology Laboratory (LACRON) samples are prepared and converted to carbon dioxide. A stainless steel vacuum system was constructed for carbon dioxide purification and graphitization is performed in sealed tubes in a muffle oven. Graphite samples will be analyzed in a 250 kV Single Stage Accelerator produced by National Electrostatic Corporation which will be installed in the beginning of 2012. With the sample preparation laboratory at LACRON and the SSAMS system, the Physics Institute of UFF will be the first 14 C-AMS facility in Latin America. (author)

  11. Ambient ionization mass spectrometry: A tutorial

    International Nuclear Information System (INIS)

    Huang, Min-Zong; Cheng, Sy-Chi; Cho, Yi-Tzu; Shiea, Jentaie

    2011-01-01

    Highlights: → Ambient ionization technique allows the direct analysis of sample surfaces with little or no sample pretreatment. → We sort ambient ionization techniques into three main analytical strategies, direct ionization, direct desorption/ionization, and two-step ionization. → The underlying principles of operation, ionization processes, detecting mass ranges, sensitivity, and representative applications of these techniques are described and compared. - Abstract: Ambient ionization is a set of mass spectrometric ionization techniques performed under ambient conditions that allows the direct analysis of sample surfaces with little or no sample pretreatment. Using combinations of different types of sample introduction systems and ionization methods, several novel techniques have been developed over the last few years with many applications (e.g., food safety screening; detection of pharmaceuticals and drug abuse; monitoring of environmental pollutants; detection of explosives for antiterrorism and forensics; characterization of biological compounds for proteomics and metabolomics; molecular imaging analysis; and monitoring chemical and biochemical reactions). Electrospray ionization and atmospheric pressure chemical ionization are the two main ionization principles most commonly used in ambient ionization mass spectrometry. This tutorial paper provides a review of the publications related to ambient ionization techniques. We describe and compare the underlying principles of operation, ionization processes, detecting mass ranges, sensitivity, and representative applications of these techniques.

  12. Maximizing Ion Transmission in Differential Mobility Spectrometry

    Science.gov (United States)

    Schneider, Bradley B.; Londry, Frank; Nazarov, Erkinjon G.; Kang, Yang; Covey, Thomas R.

    2017-10-01

    We provide modeling and experimental data describing the dominant ion-loss mechanisms for differential mobility spectrometry (DMS). Ion motion is considered from the inlet region of the mobility analyzer to the DMS exit, and losses resulting from diffusion to electrode surfaces, insufficient effective gap, ion fragmentation, and fringing field effects are considered for a commercial DMS system with 1-mm gap height. It is shown that losses due to diffusion and radial oscillations can be minimized with careful consideration of residence time, electrode spacing, gas flow rate, and waveform frequency. Fragmentation effects can be minimized by limitation of the separation field. When these parameters were optimized, fringing field effects at the DMS inlet contributed the most to signal reduction. We also describe a new DMS cell configuration that improves the gas dynamics at the mobility cell inlet. The new cell provides a gas jet that decreases the residence time for ions within the fringing field region, resulting in at least twofold increase in ion signal as determined by experimental data and simulations. [Figure not available: see fulltext.

  13. Accelerator mass spectrometry of small biological samples.

    Science.gov (United States)

    Salehpour, Mehran; Forsgard, Niklas; Possnert, Göran

    2008-12-01

    Accelerator mass spectrometry (AMS) is an ultra-sensitive technique for isotopic ratio measurements. In the biomedical field, AMS can be used to measure femtomolar concentrations of labeled drugs in body fluids, with direct applications in early drug development such as Microdosing. Likewise, the regenerative properties of cells which are of fundamental significance in stem-cell research can be determined with an accuracy of a few years by AMS analysis of human DNA. However, AMS nominally requires about 1 mg of carbon per sample which is not always available when dealing with specific body substances such as localized, organ-specific DNA samples. Consequently, it is of analytical interest to develop methods for the routine analysis of small samples in the range of a few tens of microg. We have used a 5 MV Pelletron tandem accelerator to study small biological samples using AMS. Different methods are presented and compared. A (12)C-carrier sample preparation method is described which is potentially more sensitive and less susceptible to contamination than the standard procedures.

  14. Neutron spectrometry with artificial neural networks

    International Nuclear Information System (INIS)

    Vega C, H.R.; Hernandez D, V.M.; Manzanares A, E.; Rodriguez, J.M.; Mercado S, G.A.; Iniguez de la Torre Bayo, M.P.; Barquero, R.; Arteaga A, T.

    2005-01-01

    An artificial neural network has been designed to obtain the neutron spectra from the Bonner spheres spectrometer's count rates. The neural network was trained using 129 neutron spectra. These include isotopic neutron sources; reference and operational spectra from accelerators and nuclear reactors, spectra from mathematical functions as well as few energy groups and monoenergetic spectra. The spectra were transformed from lethargy to energy distribution and were re-bin ned to 31 energy groups using the MCNP 4C code. Re-binned spectra and UTA4 response matrix were used to calculate the expected count rates in Bonner spheres spectrometer. These count rates were used as input and the respective spectrum was used as output during neural network training. After training the network was tested with the Bonner spheres count rates produced by a set of neutron spectra. This set contains data used during network training as well as data not used. Training and testing was carried out in the Mat lab program. To verify the network unfolding performance the original and unfolded spectra were compared using the χ 2 -test and the total fluence ratios. The use of Artificial Neural Networks to unfold neutron spectra in neutron spectrometry is an alternative procedure that overcomes the drawbacks associated in this ill-conditioned problem. (Author)

  15. Compressed sensing in imaging mass spectrometry

    International Nuclear Information System (INIS)

    Bartels, Andreas; Dülk, Patrick; Trede, Dennis; Alexandrov, Theodore; Maaß, Peter

    2013-01-01

    Imaging mass spectrometry (IMS) is a technique of analytical chemistry for spatially resolved, label-free and multipurpose analysis of biological samples that is able to detect the spatial distribution of hundreds of molecules in one experiment. The hyperspectral IMS data is typically generated by a mass spectrometer analyzing the surface of the sample. In this paper, we propose a compressed sensing approach to IMS which potentially allows for faster data acquisition by collecting only a part of the pixels in the hyperspectral image and reconstructing the full image from this data. We present an integrative approach to perform both peak-picking spectra and denoising m/z-images simultaneously, whereas the state of the art data analysis methods solve these problems separately. We provide a proof of the robustness of the recovery of both the spectra and individual channels of the hyperspectral image and propose an algorithm to solve our optimization problem which is based on proximal mappings. The paper concludes with the numerical reconstruction results for an IMS dataset of a rat brain coronal section. (paper)

  16. Neutron spectrometry using artificial neural networks

    International Nuclear Information System (INIS)

    Vega-Carrillo, Hector Rene; Martin Hernandez-Davila, Victor; Manzanares-Acuna, Eduardo; Mercado Sanchez, Gema A.; Pilar Iniguez de la Torre, Maria; Barquero, Raquel; Palacios, Francisco; Mendez Villafane, Roberto; Arteaga Arteaga, Tarcicio; Manuel Ortiz Rodriguez, Jose

    2006-01-01

    An artificial neural network has been designed to obtain neutron spectra from Bonner spheres spectrometer count rates. The neural network was trained using 129 neutron spectra. These include spectra from isotopic neutron sources; reference and operational spectra from accelerators and nuclear reactors, spectra based on mathematical functions as well as few energy groups and monoenergetic spectra. The spectra were transformed from lethargy to energy distribution and were re-binned to 31 energy groups using the MCNP 4C code. The re-binned spectra and the UTA4 response matrix were used to calculate the expected count rates in Bonner spheres spectrometer. These count rates were used as input and their respective spectra were used as output during the neural network training. After training, the network was tested with the Bonner spheres count rates produced by folding a set of neutron spectra with the response matrix. This set contains data used during network training as well as data not used. Training and testing was carried out using the Matlab ( R) program. To verify the network unfolding performance, the original and unfolded spectra were compared using the root mean square error. The use of artificial neural networks to unfold neutron spectra in neutron spectrometry is an alternative procedure that overcomes the drawbacks associated with this ill-conditioned problem

  17. Tandem mass spectrometry: analysis of complex mixtures

    International Nuclear Information System (INIS)

    Singleton, K.E.

    1985-01-01

    Applications of tandem mass spectrometry (MS/MS) for the analysis of complex mixtures results in increased specificity and selectivity by using a variety of reagent gases in both negative and positive ion modes. Natural isotopic abundance ratios were examined in both simple and complex mixtures using parent, daughter and neutral loss scans. MS/MS was also used to discover new compounds. Daughter scans were used to identify seven new alkaloids in a cactus species. Three of these alkaloids were novel compounds, and included the first simple, fully aromatic isoquinoline alkaloids reported in Cactaceae. MS/MS was used to characterize the chemical reaction products of coal in studies designed to probe its macromolecular structure. Negative ion chemical ionization was utilized to study reaction products resulting from the oxidation of coal. Possible structural units in the precursor coal were predicted based on the reaction products identified, aliphatic and aromatic acids and their anhydrides. The MS/MS method was also used to characterize reaction products resulting from coal liquefaction and/or extraction. These studies illustrate the types of problems for which MS/MS is useful. Emphasis has been placed on characterization of complex mixtures by selecting experimental parameters which enhance the information obtained. The value of using MS/MS in conjunction with other analytical techniques as well as the chemical pretreatment is demonstrated

  18. Composite mapping experiences in airborne gamma spectrometry.

    Science.gov (United States)

    Bucher, B

    2014-08-01

    During an international intercomparison exercise of airborne gamma spectrometry held in Switzerland 2007 teams from Germany, France and Switzerland were proving their capabilities. One of the tasks was the composite mapping of an area around Basel. Each team was mainly covering the part of its own country at its own flying procedures. They delivered the evaluated data in a data format agreed in advance. The quantities to be delivered were also defined in advance. Nevertheless, during the process to put the data together a few questions raised: Which dose rate was meant? Had the dose rate to be delivered with or without cosmic contribution? Activity per dry or wet mass? Which coordinate system was used? Finally, the data could be put together in one map. For working procedures in case of an emergency, quantities of interest and exchange data format have to be defined in advance. But the procedures have also to be proved regularly. © The Author 2014. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  19. Determination of mercury in hair: Comparison between gold amalgamation-atomic absorption spectrometry and mass spectrometry.

    Science.gov (United States)

    Domanico, Francesco; Forte, Giovanni; Majorani, Costanza; Senofonte, Oreste; Petrucci, Francesco; Pezzi, Vincenzo; Alimonti, Alessandro

    2017-09-01

    Mercury is a heavy metal that causes serious health problems in exposed subjects. The most toxic form, i.e., methylmercury (MeHg), is mostly excreted through human hair. Numerous analytical methods are available for total Hg analysis in human hair, including cold vapour atomic fluorescence spectrometry (CV-AFS), inductively coupled plasma mass spectrometry (ICP-MS) and thermal decomposition amalgamation atomic absorption spectrometry (TDA-AAS). The aim of the study was to compare the TDA-AAS with the ICP-MS in the Hg quantification in human hair. After the washing procedure to minimize the external contamination, from each hair sample two aliquots were taken; the first was used for direct analysis of Hg by TDA-AAS and the second was digested for Hg determination by the ICP-MS. Results indicated that the two data sets were fully comparable (median; TDA-AAS, 475ngg -1 ; ICP-MS, 437ngg -1 ) and were not statistically different (Mann-Whitney test; p=0.44). The two techniques presented results with a good coefficient of correlation (r=0.94) despite different operative ranges and method limits. Both techniques satisfied internal performance requirements and the parameters for method validation resulting sensitive, precise and reliable. Finally, the use of the TDA-AAS can be considered instead of the ICP-MS in hair analysis in order to reduce sample manipulation with minor risk of contamination, less time consuming due to the absence of the digestion step and cheaper analyses. Copyright © 2016 Elsevier GmbH. All rights reserved.

  20. Microbial metabolomics with gas chromatography/mass spectrometry

    NARCIS (Netherlands)

    Koek, M.M.; Muilwijk, B.; Werf, M.J. van der; Hankemeier, T.

    2006-01-01

    An analytical method was set up suitable for the analysis of microbial metabolomes, consisting of an oximation and silylation derivatization reaction and subsequent analysis by gas chromatography coupled to mass spectrometry. Microbial matrixes contain many compounds that potentially interfere with

  1. Applications of thermal lens spectrometry in food industry and agriculture.

    NARCIS (Netherlands)

    Franko, M.; Bicanic, D.; Gibkes, J.; Bremer, M.; Akkermans, E.

    1996-01-01

    Applications of CO laser dual beam thermal lens spectrometry (TLS) for detection and characterization of fatty acids, aldehydes, pesticides, and herbicides in liquid samples are described. Also reported is the first TLS measurement of thermal conductivity for oleic acid.

  2. Gamma ray spectrometry: applications in uranium prospecting and environment

    International Nuclear Information System (INIS)

    Lopez, Luis E.

    1999-01-01

    The experience in the use of gamma spectrometry for uranium prospecting and for the determination of natural radiation background is described. The basic principles of the techniques are also given. (author)

  3. Some deficiencies and solutions in gamma ray spectrometry

    International Nuclear Information System (INIS)

    Westmeier, W.

    1998-01-01

    A number of problems in high-resolution gamma ray spectrometry as well as some deficiencies of existing computer programs for the quantitative evaluation of spectra are discussed and some practical solutions are proposed. (author)

  4. Sampling and analyte enrichment strategies for ambient mass spectrometry.

    Science.gov (United States)

    Li, Xianjiang; Ma, Wen; Li, Hongmei; Ai, Wanpeng; Bai, Yu; Liu, Huwei

    2018-01-01

    Ambient mass spectrometry provides great convenience for fast screening, and has showed promising potential in analytical chemistry. However, its relatively low sensitivity seriously restricts its practical utility in trace compound analysis. In this review, we summarize the sampling and analyte enrichment strategies coupled with nine modes of representative ambient mass spectrometry (desorption electrospray ionization, paper vhspray ionization, wooden-tip spray ionization, probe electrospray ionization, coated blade spray ionization, direct analysis in real time, desorption corona beam ionization, dielectric barrier discharge ionization, and atmospheric-pressure solids analysis probe) that have dramatically increased the detection sensitivity. We believe that these advances will promote routine use of ambient mass spectrometry. Graphical abstract Scheme of sampling stretagies for ambient mass spectrometry.

  5. Analytical strategies in mass spectrometry-based phosphoproteomics

    DEFF Research Database (Denmark)

    Rosenqvist, Heidi; Ye, Juanying; Jensen, Ole N

    2011-01-01

    then discuss various tandem mass spectrometry approaches for phosphopeptide sequencing and quantification, and we consider aspects of phosphoproteome data analysis and interpretation. Efficient integration of these stages of phosphoproteome analysis is highly important to ensure a successful outcome of large...

  6. Biomarker discovery in high grade sarcomas by mass spectrometry imaging

    OpenAIRE

    Lou, S.

    2017-01-01

    This thesis demonstrates a detailed biomarker discovery Mass Spectrometry Imaging workflow for histologically heterogeneous high grade sarcomas. Panels of protein and metabolite signatures were discovered either distinguishing different histological subtypes or stratifying high risk patients with poor survival.

  7. A theory of stable-isotope dilution mass spectrometry

    International Nuclear Information System (INIS)

    Pickup, J.F.; McPherson, C.K.

    1977-01-01

    In order to perform quantitative analysis using stable isotope dilution with mass spectrometry, an equation is derived which describes the relationship between the relative proportions of natural and labelled material and measured isotope ratios

  8. Chemical ionisation mass spectrometry: a survey of instrument technology

    International Nuclear Information System (INIS)

    Mather, R.E.; Todd, J.F.J.

    1979-01-01

    The purpose of this review is to survey the innovations and improvements which have been made in both instrumentation and methodology in chemical ionization mass spectrometry in the past ten years. (Auth.)

  9. 13th International Mass Spectrometry Conference. Book of Abstracts

    International Nuclear Information System (INIS)

    1994-01-01

    The collection contains abstracts of several hundred papers presented at the international conference on new research and development results and applications of mass spectrometry. Abstracts falling into the INIS scope were indexed separately in the INIS database. (Roboz, P.)

  10. OBT measurement of vegetation by mass spectrometry and radiometry

    International Nuclear Information System (INIS)

    Tamari, T.; Kakiuchi, H.; Momoshima, N.; Sugihara, S.; Baglan, N.; Uda, T.

    2011-01-01

    We carried out OBT (organically bound tritium) measurement by two different methods those are radiometry and mass spectrometry and compared the applicability of these methods for environmental tritium analysis. The dried grass sample was used for the experiments. To eliminate the exchangeable OBT, the sample was washed with tritium free water before analysis. Three times washing reduced the tritium activity in the labile sites below the detectable level. In radiometry the sample was combusted to convert the OBT as well as other hydrogen isotopes to. water and tritium activity in the water was measured by liquid scintillation counting (LSC). In mass spectrometry, the sample was kept in a glass container and 3 He produced by tritium decay was measured by mass spectrometry. The results were in good agreement suggesting applicability of these methods for environmental tritium analysis. The mass spectrometry is more suitable for environmental tritium research because of a lower detection limit than that of the LSC. (authors)

  11. Laser mass spectrometry for DNA sequencing, disease diagnosis, and fingerprinting

    Energy Technology Data Exchange (ETDEWEB)

    Winston Chen, C.H.; Taranenko, N.I.; Zhu, Y.F.; Chung, C.N.; Allman, S.L.

    1997-03-01

    Since laser mass spectrometry has the potential for achieving very fast DNA analysis, the authors recently applied it to DNA sequencing, DNA typing for fingerprinting, and DNA screening for disease diagnosis. Two different approaches for sequencing DNA have been successfully demonstrated. One is to sequence DNA with DNA ladders produced from Snager`s enzymatic method. The other is to do direct sequencing without DNA ladders. The need for quick DNA typing for identification purposes is critical for forensic application. The preliminary results indicate laser mass spectrometry can possibly be used for rapid DNA fingerprinting applications at a much lower cost than gel electrophoresis. Population screening for certain genetic disease can be a very efficient step to reducing medical costs through prevention. Since laser mass spectrometry can provide very fast DNA analysis, the authors applied laser mass spectrometry to disease diagnosis. Clinical samples with both base deletion and point mutation have been tested with complete success.

  12. Recent applications of mass spectrometry in forensic toxicology

    Science.gov (United States)

    Foltz, Rodger L.

    1992-09-01

    This review encompasses applications of mass spectrometry reported during the years 1989, 1990 and 1991 for the analysis of cannabinoids, cocaine, opiates, amphetamines, lysergic acid diethylamide (LSD), and their metabolites in physiological specimens.

  13. Dehydrodimerization of pterostilbene during electrospray ionization mass spectrometry

    KAUST Repository

    Raji, Misjudeen; Amad, Maan H.; Emwas, Abdul-Hamid M.

    2013-01-01

    RATIONALE Pterostilbene is a member of the hydroxystilbene family of compounds commonly found in plants such as blueberry and grapes. During the analysis of this compound by electrospray ionization mass spectrometry (ESI-MS), an ion was observed

  14. 13th International Mass Spectrometry Conference. Book of Abstracts

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1994-12-31

    The collection contains abstracts of several hundred papers presented at the international conference on new research and development results and applications of mass spectrometry. Abstracts falling into the INIS scope were indexed separately in the INIS database. (Roboz, P.).

  15. RadNet Real-Time Monitoring Spectrometry Data Inventory

    Data.gov (United States)

    U.S. Environmental Protection Agency — The RadNet Real-Time Monitoring Spectrometry Data Inventory contains measured data used to identify and measure specific radioactive materials in the atmosphere at...

  16. Gas Chromatography Mass Spectrometry of Quassia undulata Seed ...

    African Journals Online (AJOL)

    Prof. Ogunji

    The use of gas chromatography mass spectrometry (GC MS) as a sensitive and specific technique ... cold flow properties and stability of the fuel to oxidation, peroxidation and polymerization .... determinants of both the physical and chemical ...

  17. Plutonium determination in urine by techniques of mass spectrometry

    International Nuclear Information System (INIS)

    Hernandez M, H.; Yllera de Ll, A.

    2013-10-01

    The objective of this study was to develop an analytic method for quantification and plutonium reappraisal in plane tables of alpha spectrometry be means of the mass spectrometry technique of high resolution with plasma source inductively coupled and desolvator Aridus (Aridus-Hr-Icp-Ms) and mass spectrometry with accelerator (AMS). The obtained results were, the recovery percentage of Pu in the plane table was of ∼ 90% and activity minimum detectable obtained with Aridus-Hr-Icp-Ms and AMS was of ∼ 3 and ∼ 0.4 f g of 239 Pu, respectively. Conclusion, the results demonstrate the aptitude of the Aridus-Hr-Icp-Ms and AMS techniques in the Pu reappraisal in plane tables with bigger speed and precision, improving the values notably of the activity minimum detectable that can be obtained with the alpha spectrometry (∼ 50 f g of 239 Pu). (author)

  18. Rapid environmental surveying using mobile gamma ray spectrometry Processing of results from the RESUME99 exercise, Gaevle, Sweden

    CERN Document Server

    Smetkurst, M A

    2000-01-01

    Data from mobile measuring teams participating in the RESUME99 Fixed Route exercise in Sweden have been processed to facilitate a detailed comparison between the data sets. The exercise was organised by the Swedish Radiation Protection Institute (SSI) and is part of the BOK-1.2 project Mobile Measurements and Measurements Strategies within the Nordic Nuclear Safety Research (NKS) programme for 1998-2000. 11 car borne gamma ray spectrometer systems measured a fixed route in the vicinity of Gaevle in Sweden so that the capabilities of the different measuring systems in determining the levels and patterns of sup 1 37Cs contamination along the route could be studied. This report describes how the data sets from the different measuring systems were projected into the known trace of the fixed route so that the results can be compared. Estimates of equivalent surface activity of sup 1 37Cs from the different measuring systems were normalised to data obtained by the Danish Emergency management Agency (system DKA1) an...

  19. The allure of mass spectrometry: From an earlyday chemist's perspective.

    Science.gov (United States)

    Tőkés, László

    2017-07-01

    This reminiscing review article is an account of the author's fascination and involvements with mass spectrometry from the perspective of an organic chemist with an interest in natural product chemistry. It covers a period from 1961 through the mid 1990s as mass spectrometry evolved form a novelty technique to become a most widely used analytical technique. Following a brief synopsis of my pathway to mass spectrometry, my research efforts in this field are presented with a focus mainly on evolving principles and technologies which I had personal involvements with. To provide historical perspectives, discussions of these developments are accompanied by brief outlines of the relevant state-of-the-art, shedding light on the technical and conceptual challenges encountered during those early days in mass spectrometry. Examples are presented of my involvements with basic and applied research in mass spectrometry during graduate studies at Stanford University and close to three decade tenure in pharmaceutical research at Syntex Research. My basic research interests focused mainly on principles of electron ionization induced fragmentation mechanisms, with an emphasis on steroids and other model compounds. Extensive deuterium labeling evidence was used to determine the fragmentation mechanisms of the diagnostically significant ions in the spectra of numerous model compounds, uncovering examples of wide-ranging hydrogen transfers, skeletal rearrangements, methyl and phenyl migrations, stereoselective fragmentations and low and high energy fragmentation processes. Depiction of the industrial research phase of my career includes comments on the pivotal role mass spectrometry played on advancing modern pharmaceutical research. Examples are presented of involvements with instrumental developments and a few select cases of applied research, including studies of bile mechanisms in vertebrates, identification of bisphenol-A leaching from sterilized polycarbonate containers, high

  20. Interpretation of Tandem Mass Spectrometry (MSMS) Spectra for Peptide Analysis

    DEFF Research Database (Denmark)

    Hjernø, Karin; Højrup, Peter

    2015-01-01

    The aim of this chapter is to give a short introduction to peptide analysis by mass spectrometry (MS) and interpretation of fragment mass spectra. Through examples and guidelines we demonstrate how to understand and validate search results and how to perform de novo sequencing based on the often...... very complex fragmentation pattern obtained by tandem mass spectrometry (also referred to as MSMS). The focus is on simple rules for interpretation of MSMS spectra of tryptic as well as non-tryptic peptides....

  1. Subcellular analysis by laser ablation electrospray ionization mass spectrometry

    Science.gov (United States)

    Vertes, Akos; Stolee, Jessica A; Shrestha, Bindesh

    2014-12-02

    In various embodiments, a method of laser ablation electrospray ionization mass spectrometry (LAESI-MS) may generally comprise micro-dissecting a cell comprising at least one of a cell wall and a cell membrane to expose at least one subcellular component therein, ablating the at least one subcellular component by an infrared laser pulse to form an ablation plume, intercepting the ablation plume by an electrospray plume to form ions, and detecting the ions by mass spectrometry.

  2. Training course on inductively coupled plasma spectrometry - Note

    Digital Repository Service at National Institute of Oceanography (India)

    Valsangkar, A.B.

    TRAINING COURSE ON INDUCTIVELY COUPLED PLASMA SPECTROMETRY In the present day geological, chemical, environmental and archaeological research activities, the Inductively Coupled Plasma (ICP) Spectrometry is established as a cost-effective multi... the knowledge and advances in the analytical tools and methodologies for the benefit of the research scholars as well as professionals. National Institute of Oceanography, A.B. VALSANGKAR Dona Paula - 403 004 slip tectonics playing a major role...

  3. Atomization mechanisms for barium in furnace atomic absorption spectrometry

    International Nuclear Information System (INIS)

    Styris, D.L.

    1984-01-01

    Atomic absorption spectrometry and mass spectrometry are used simultaneously in order to elucidate atomization mechanisms of barium dichloride in pyrolytic graphite, vitreous carbon, and tantalum furnaces. Gas-phase barium dicarbide is observed to appear concurrently with the free barium. Barium oxide and barium dihydroxide precursors appear with the chlorides. Surface reactions involving species that are absorbed on the various furnaces are postulated to explain the appearances of the species that are observed in the gas phase. 49 references, 4 figures, 1 table

  4. Automated, parallel mass spectrometry imaging and structural identification of lipids

    DEFF Research Database (Denmark)

    Ellis, Shane R.; Paine, Martin R.L.; Eijkel, Gert B.

    2018-01-01

    We report a method that enables automated data-dependent acquisition of lipid tandem mass spectrometry data in parallel with a high-resolution mass spectrometry imaging experiment. The method does not increase the total image acquisition time and is combined with automatic structural assignments....... This lipidome-per-pixel approach automatically identified and validated 104 unique molecular lipids and their spatial locations from rat cerebellar tissue....

  5. Quantification of steroid conjugates using fast atom bombardment mass spectrometry

    International Nuclear Information System (INIS)

    Gaskell, S.J.

    1990-01-01

    Fast atom bombardment/mass spectrometry or liquid secondary ion mass spectrometry provides the capability for direct analysis of steroid conjugates (sulfates, glucuronides) without prior hydrolysis or derivatization. During the analysis of biologic extracts, limitations on the sensitivity of detection arise from the presence of co-extracted material which may suppress or obscure the analyte signal. A procedure is described for the quantitative determination of dehydroepiandrosterone sulfate in serum which achieved selective isolation of the analyte using immunoadsorption extraction and highly specific detection using tandem mass spectrometry. A stable isotope-labeled analog [( 2H2]dehydroepiandrosterone sulfate) was used as internal standard. Fast atom bombardment of dehydroepiandrosterone sulfate yielded abundant [M-H]- ions that fragmented following collisional activation to give HSO4-; m/z 97. During fast atom bombardment/tandem mass spectrometry of serum extracts, a scan of precursor ions fragmenting to give m/z 97 detected dehydroepiandrosterone sulfate and the [2H2]-labeled analog with a selectivity markedly superior to that observed using conventional mass spectrometry detection. Satisfactory agreement was observed between quantitative data obtained in this way and data obtained by gas chromatography/mass spectrometry of the heptafluorobutyrates of dehydroepiandrosterone sulfate and [2H2]dehydroepiandrosterone sulfate obtained by direct derivatization. 21 refs

  6. Emerging mass spectrometry techniques for the direct analysis of microbial colonies

    OpenAIRE

    Fang, Jinshu; Dorrestein, Pieter C.

    2014-01-01

    One of the emerging areas in microbiology is detecting specialized metabolites produced by microbial colonies and communities with mass spectrometry. In this review/perspective, we illustrate the emerging mass spectrometry methodologies that enable the interrogation of specialized metabolites directly from microbial colonies. Mass spectrometry techniques such as imaging mass spectrometry and real-time mass spectrometry allow two and three dimensional visualization of the distri...

  7. Analysis of organic compounds by secondary neutral mass spectrometry (SNMS) and secondary ion mass spectrometry (SIMS)

    International Nuclear Information System (INIS)

    Ewinger, H.P.

    1993-05-01

    This study is about the use of secondary neutral mass spectrometry (SNMS) and secondary ion mass spectrometry (SIMS) as analytical techniques with depth resolution in determining organic components in environmental solid microparticles. The first application of plasma SNMS to organic compounds revealed the spectra to be composed mainly of signals from the atoms of all participating elements, such as C, H, O, N, S, P, and Cl. In addition, signals produced by multi-atomic clusters can be detected, such as CH, C 2 , CH 2 , C 2 H, and C 3 , as well as signals indicating the presence of organic compounds with hetero elements, such as OH, NH, and CN. Their intensity decreases very markedly with increasing numbers of atoms. Among the signals from bi-atomic clusters, those coming from elements with large mass differences are most intense. The use of plasma SNMS with organic compounds has shown that, except for spurious chemical reactions induced by ion bombardment and photodesorption by the photons of the plasma, it is possible to analyze with resolution in depth, elements of organic solids. A more detailed molecular characterization of organic compounds is possible by means of SIMS on the basis of multi-atomic fragments and by comparison with suitable signal patterns. (orig./BBR) [de

  8. Characterization of a Distributed Plasma Ionization Source (DPIS) for Ion Mobility Spectrometry and Mass Spectrometry

    International Nuclear Information System (INIS)

    Waltman, Melanie J.; Dwivedi, Prabha; Hill, Herbert; Blanchard, William C.; Ewing, Robert G.

    2008-01-01

    A recently developed atmospheric pressure ionization source, a distributed plasma ionization source (DPIS), was characterized and compared to commonly used atmospheric pressure ionization sources with both mass spectrometry and ion mobility spectrometry. The source consisted of two electrodes of different sizes separated by a thin dielectric. Application of a high RF voltage across the electrodes generated plasma in air yielding both positive and negative ions depending on the polarity of the applied potential. These reactant ions subsequently ionized the analyte vapors. The reactant ions generated were similar to those created in a conventional point-to-plane corona discharge ion source. The positive reactant ions generated by the source were mass identified as being solvated protons of general formula (H2O)nH+ with (H2O)2H+ as the most abundant reactant ion. The negative reactant ions produced were mass identified primarily as CO3-, NO3-, NO2-, O3- and O2- of various relative intensities. The predominant ion and relative ion ratios varied depending upon source construction and supporting gas flow rates. A few compounds including drugs, explosives and environmental pollutants were selected to evaluate the new ionization source. The source was operated continuously for several months and although deterioration was observed visually, the source continued to produce ions at a rate similar that of the initial conditions. The results indicated that the DPIS may have a longer operating life than a conventional corona discharge.

  9. Ion mobility spectrometry-hydrogen deuterium exchange mass spectrometry of anions: part 1. Peptides to proteins.

    Science.gov (United States)

    Donohoe, Gregory C; Khakinejad, Mahdiar; Valentine, Stephen J

    2015-04-01

    Ion mobility spectrometry (IMS) coupled with hydrogen deuterium exchange (HDX)-mass spectrometry (MS) has been used to study the conformations of negatively-charged peptide and protein ions. Results are presented for ion conformers of angiotensin 1, a synthetic peptide (SP), bovine insulin, ubiquitin, and equine cytochrome c. In general, the SP ion conformers demonstrate a greater level of HDX efficiency as a greater proportion of the sites undergo HDX. Additionally, these ions exhibit the fastest rates of exchange. Comparatively, the angiotensin 1 ions exhibit a lower rate of exchange and HDX level presumably because of decreased accessibility of exchange sites by charge sites. The latter are likely confined to the peptide termini. Insulin ions show dramatically reduced HDX levels and exchange rates, which can be attributed to decreased conformational flexibility resulting from the disulfide bonds. For the larger ubiquitin and protein ions, increased HDX is observed for larger ions of higher charge state. For ubiquitin, a conformational transition from compact to more elongated species (from lower to higher charge states) is reflected by an increase in HDX levels. These results can be explained by a combination of interior site protection by compact conformers as well as decreased access by charge sites. The elongated cytochrome c ions provide the largest HDX levels where higher values correlate with charge state. These results are consistent with increased exchange site accessibility by additional charge sites. The data from these enhanced IMS-HDX experiments are described in terms of charge site location, conformer rigidity, and interior site protection.

  10. Bulk media assay using backscattered neutron spectrometry

    International Nuclear Information System (INIS)

    Csikai, J.

    2000-01-01

    This paper summarized a systematic study of bulk media assay using backscattered neutron spectrometry. The source-sample-detector geometry used for the measurements of leakage and elastically backscattered (EBS) spectra of neutrons is shown. Neutrons up to about 14 MeV were produced via 2 H (d,n) and 9 Be (d,n) reactions using different deuteron beam energies between 5 and 10 MeV at the MGC-20E cyclotron of ATOMKI (Debrecen). Neutron yields of the Pu-Be and 252 Cf sources were 5.25 x 10 6 n/s and 1.8 x 10 6 n/s, respectively. Flux density distributions of thermal and primary 14 MeV neutrons were measured for graphite, water and coal samples in various moderator (M)-sample (S)-reflector (R) geometries. Relative fractions and integrated yields of 252 Cf, Pu-Be and 14 MeV neutrons above the (n,n'γ) reaction thresholds for 12 C, 16 O and 28 Si isotopes vs sample thickness have also been determined. It was found that the integrated reaction rate vs sample thickness decreasing exponentially with different attenuation coefficients depending on the neutron spectrum and the composition of the sample. The spectra of neutrons from sources passing through slabs of water, graphite, sand, Al, Fe and Pb up to 20 cm in thickness have been measured by a PHRS system in the 1.2 to 1.5 MeV range. The leakage neutron spectra from a Pu-Be source placed in the center of 30 cm diameter sphere filled with water, paraffin oil, SiO 2 , zeolite and river sand were also measured. The measured spectra have been compared with the calculated results obtained by the three dimensional Monte-Carlo code MCNP-4A and point-wise cross sections from the ENDF/B-4, ENDF/B-6, ENDF/E-1, BROND-2 and JENDL-3.1 data files. New results were obtained for validation of different data libraries from a comparison on the measured and the calculated spectra. Some typical results for water, Al, sand and Fe are shown. A combination of the backscattered neutron spectrometry with the surface gauge used both for the

  11. Mass spectrometry of acoustically levitated droplets.

    Science.gov (United States)

    Westphall, Michael S; Jorabchi, Kaveh; Smith, Lloyd M

    2008-08-01

    Containerless sample handling techniques such as acoustic levitation offer potential advantages for mass spectrometry, by eliminating surfaces where undesired adsorption/desorption processes can occur. In addition, they provide a unique opportunity to study fundamental aspects of the ionization process as well as phenomena occurring at the air-droplet interface. Realizing these advantages is contingent, however, upon being able to effectively interface levitated droplets with a mass spectrometer, a challenging task that is addressed in this report. We have employed a newly developed charge and matrix-assisted laser desorption/ionization (CALDI) technique to obtain mass spectra from a 5-microL acoustically levitated droplet containing peptides and an ionic matrix. A four-ring electrostatic lens is used in conjunction with a corona needle to produce bursts of corona ions and to direct those ions toward the droplet, resulting in droplet charging. Analyte ions are produced from the droplet by a 337-nm laser pulse and detected by an atmospheric sampling mass spectrometer. The ion generation and extraction cycle is repeated at 20 Hz, the maximum operating frequency of the laser employed. It is shown in delayed ion extraction experiments that both positive and negative ions are produced, behavior similar to that observed for atmospheric pressure matrix-assisted laser absorption/ionization. No ion signal is observed in the absence of droplet charging. It is likely, although not yet proven, that the role of the droplet charging is to increase the strength of the electric field at the surface of the droplet, reducing charge recombination after ion desorption.

  12. Radionuclide content of simulated and fully radioactive SRLLL waste glasses: comparison of results from ICP-MS, gamma spectrometry and alpha spectrometry

    International Nuclear Information System (INIS)

    Wolf, S.F.; Bates, J.K.

    1995-01-01

    We have measured the transuranic content of two transuranic=doped, simulated waste glasses, using inductively coupled plasma-mass spectrometry (ICP-MS), γ-spectrometry, and α-spectrometry. Average concentrations measured by each technique were within ± 10% of the as-doped concentrations. We also report the transuranic content of three fully radioactive SRL waste glasses that were determined using γ- and α-spectrometry measurements to deconvolute isobaric interferences present in the ICP-MS analyses

  13. Qualitative analysis of Th-232 in soil samples with portable radiological identifiers NaI (Tl) and LaBr{sub 3} (Ce); Análise qualitativa de Th-232 em amostras de solo com identificadores radiológicos portáteis NaI(Tl) e LaBr{sub 3}(Ce)

    Energy Technology Data Exchange (ETDEWEB)

    Oliveira, L.S.R.; Amorim, A.S.; Balthar, M.C.V.; Vilela, P.RT.; Santos, A. [Instituto de Defesa, Química, Biológica, Radiológica e Nuclear (IDQBRN), Rio de Janeiro, RJ (Brazil); Cardoso, D.O.; Izidoro, A.C.A.C. [Instituto Militar de Engenharia (IME), Rio de Janeiro, RJ (Brazil); Pelegrineli, S.Q.; Silva, L.B.; Silva, S.L. [MAXIM Treinamento e Assessoria, Rio de Janeiro, RJ (Brazil); Santos, F.R.; Ribeiro, C.A.M.; Silva, D.C., E-mail: lucianosantarita@gmail.com, E-mail: domingosoliveiralvr71@gmail.com, E-mail: samuelfisica@yahoo.com.br [Universidade Estácio de Sá, Rio de Janeiro, RJ (Brazil)

    2017-07-01

    The identification of the occurrence of Th-232 in open environments using portable radiological identifiers (IRP) with scintillators, discriminating the environmental condition and NORM is important for the operational teams of the Institute of Chemical, Biological, Radiological and Nuclear Defense (IDQBRN) of the Army. The qualitative analysis by gamma energy spectrometry for the energies of Th-232 and its daughter radioisotopes, given the resolution that characterizes the scintillation crystals (NaI (Tl) - 7.5% and LaBr{sub 3} (Ce) - 2.9%) makes it possible to identify them. The purpose is to perform a qualitative analysis of the reliability of the response of these IRPs to the measurements of Th-232 generally found in the environment and in samples extracted from points where the thorium concentration is highest. The results show that the identification of this radionuclide by the IRP in the samples with the highest natural occurrence is achieved by measuring the energies of the daughter isotopes Ac-228, Tl-208, Bi-212 and Pb-212 allowing the discrimination of soils with natural occurrence of Th -232 and NORM. These measurements will be based on the procedures used by the operational teams in the field actions aimed at reducing exposure to this radiation, both for individuals occupationally exposed and for the population.

  14. Gamma spectrometry for chronology of recent sediments

    International Nuclear Information System (INIS)

    Pittauerova, Daniela

    2013-01-01

    This thesis deals with several aspects of gamma spectrometric analysis of natural and artificial isotopes in sediments and their use as tracers for qualification and quantification of accumulation and mixing processes in different aquatic environments. Sediment cores from three distinct areas including terrigenous sediments deposited on the continental slope off NW Africa, deep sea sediments off Sumba Island and five stations from the Gulf of Eilat in the Red Sea area were measured and interpreted within this dissertation. The main concern in gamma spectrometry of voluminous environmental samples is a reliable efficiency calibration. This is specially relevant for the analysis of low energy gamma emitters (<100 keV). 210 Pb, an important isotopic tracer to cover the period of the last century, is one of them. Within this work mathematical efficiency calibration was applied using a commercial software package. A series of validation tests was performed and evaluated for point and voluminous samples. When using 210 Pb as a tracer it is necessary to determine its excess portion, which is not supported by ingrowth from the parent nuclide 226 Ra. Its analysis is mostly performed via short lived daughter isotopes that follow after the intermediate gaseous member 222 Rn. Preventing the escape of radon from the sample is a critical step before analysis due to a negative effect of supported 210 Pb underestimation on the chronology, which was also documented in this thesis. Time series registering ingrowth of 214 Pb and 214 Bi towards radioactive equilibrium with 226 Ra in different containers were evaluated for analyses of 226 Ra. Direct analyses of 226 Ra was compared to its detection via daughter products. A method for aligning parallel radionuclide depth profiles was described and applied successfully in two case studies from the continental slope off NW Africa and off Sumba Island, Indonesia. This is primarily important when combined profiles obtained from short

  15. Gamma spectrometry for chronology of recent sediments

    Energy Technology Data Exchange (ETDEWEB)

    Pittauerova, Daniela

    2013-12-17

    This thesis deals with several aspects of gamma spectrometric analysis of natural and artificial isotopes in sediments and their use as tracers for qualification and quantification of accumulation and mixing processes in different aquatic environments. Sediment cores from three distinct areas including terrigenous sediments deposited on the continental slope off NW Africa, deep sea sediments off Sumba Island and five stations from the Gulf of Eilat in the Red Sea area were measured and interpreted within this dissertation. The main concern in gamma spectrometry of voluminous environmental samples is a reliable efficiency calibration. This is specially relevant for the analysis of low energy gamma emitters (<100 keV). {sup 210}Pb, an important isotopic tracer to cover the period of the last century, is one of them. Within this work mathematical efficiency calibration was applied using a commercial software package. A series of validation tests was performed and evaluated for point and voluminous samples. When using {sup 210}Pb as a tracer it is necessary to determine its excess portion, which is not supported by ingrowth from the parent nuclide {sup 226}Ra. Its analysis is mostly performed via short lived daughter isotopes that follow after the intermediate gaseous member {sup 222}Rn. Preventing the escape of radon from the sample is a critical step before analysis due to a negative effect of supported {sup 210}Pb underestimation on the chronology, which was also documented in this thesis. Time series registering ingrowth of {sup 214}Pb and {sup 214}Bi towards radioactive equilibrium with {sup 226}Ra in different containers were evaluated for analyses of {sup 226}Ra. Direct analyses of {sup 226}Ra was compared to its detection via daughter products. A method for aligning parallel radionuclide depth profiles was described and applied successfully in two case studies from the continental slope off NW Africa and off Sumba Island, Indonesia. This is primarily important

  16. Investigation of drift gas selectivity in high resolution ion mobility spectrometry with mass spectrometry detection.

    Science.gov (United States)

    Matz, Laura M; Hill, Herbert H; Beegle, Luther W; Kanik, Isik

    2002-04-01

    Recent studies in electrospray ionization (ESI)/ion mobility spectrometry (IMS) have focussed on employing different drift gases to alter separation efficiency for some molecules. This study investigates four structurally similar classes of molecules (cocaine and metabolites, amphetamines, benzodiazepines, and small peptides) to determine the effect of structure on relative mobility changes in four drift gases (helium, nitrogen, argon, carbon dioxide). Collision cross sections were plotted against drift gas polarizability and a linear relationship was found for the nineteen compounds evaluated in the study. Based on the reduced mobility database, all nineteen compounds could be separated in one of the four drift gases, however, the drift gas that provided optimal separation was specific for the two compounds.

  17. imzML: Imaging Mass Spectrometry Markup Language: A common data format for mass spectrometry imaging.

    Science.gov (United States)

    Römpp, Andreas; Schramm, Thorsten; Hester, Alfons; Klinkert, Ivo; Both, Jean-Pierre; Heeren, Ron M A; Stöckli, Markus; Spengler, Bernhard

    2011-01-01

    Imaging mass spectrometry is the method of scanning a sample of interest and generating an "image" of the intensity distribution of a specific analyte. The data sets consist of a large number of mass spectra which are usually acquired with identical settings. Existing data formats are not sufficient to describe an MS imaging experiment completely. The data format imzML was developed to allow the flexible and efficient exchange of MS imaging data between different instruments and data analysis software.For this purpose, the MS imaging data is divided in two separate files. The mass spectral data is stored in a binary file to ensure efficient storage. All metadata (e.g., instrumental parameters, sample details) are stored in an XML file which is based on the standard data format mzML developed by HUPO-PSI. The original mzML controlled vocabulary was extended to include specific parameters of imaging mass spectrometry (such as x/y position and spatial resolution). The two files (XML and binary) are connected by offset values in the XML file and are unambiguously linked by a universally unique identifier. The resulting datasets are comparable in size to the raw data and the separate metadata file allows flexible handling of large datasets.Several imaging MS software tools already support imzML. This allows choosing from a (growing) number of processing tools. One is no longer limited to proprietary software, but is able to use the processing software which is best suited for a specific question or application. On the other hand, measurements from different instruments can be compared within one software application using identical settings for data processing. All necessary information for evaluating and implementing imzML can be found at http://www.imzML.org .

  18. A deviation display method for visualising data in mobile gamma-ray spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Kock, Peder, E-mail: Peder.Kock@med.lu.s [Department of Medical Radiation Physics, Clinical Sciences, Lund University, University Hospital, SE-221 85 Lund (Sweden); Finck, Robert R. [Swedish Radiation Protection Authority, SE-171 16 Stockholm (Sweden); Nilsson, Jonas M.C.; Ostlund, Karl; Samuelsson, Christer [Department of Medical Radiation Physics, Clinical Sciences, Lund University, University Hospital, SE-221 85 Lund (Sweden)

    2010-09-15

    A real time visualisation method, to be used in mobile gamma-spectrometric search operations using standard detector systems is presented. The new method, called deviation display, uses a modified waterfall display to present relative changes in spectral data over energy and time. Using unshielded {sup 137}Cs and {sup 241}Am point sources and different natural background environments, the behaviour of the deviation displays is demonstrated and analysed for two standard detector types (NaI(Tl) and HPGe). The deviation display enhances positive significant changes while suppressing the natural background fluctuations. After an initialisation time of about 10 min this technique leads to a homogeneous display dominated by the background colour, where even small changes in spectral data are easy to discover. As this paper shows, the deviation display method works well for all tested gamma energies and natural background radiation levels and with both tested detector systems.

  19. A deviation display method for visualising data in mobile gamma-ray spectrometry

    International Nuclear Information System (INIS)

    Kock, Peder; Finck, Robert R.; Nilsson, Jonas M.C.; Ostlund, Karl; Samuelsson, Christer

    2010-01-01

    A real time visualisation method, to be used in mobile gamma-spectrometric search operations using standard detector systems is presented. The new method, called deviation display, uses a modified waterfall display to present relative changes in spectral data over energy and time. Using unshielded 137 Cs and 241 Am point sources and different natural background environments, the behaviour of the deviation displays is demonstrated and analysed for two standard detector types (NaI(Tl) and HPGe). The deviation display enhances positive significant changes while suppressing the natural background fluctuations. After an initialisation time of about 10 min this technique leads to a homogeneous display dominated by the background colour, where even small changes in spectral data are easy to discover. As this paper shows, the deviation display method works well for all tested gamma energies and natural background radiation levels and with both tested detector systems.

  20. An investigation of the repeatability of calibration factors in gamma-ray spectrometry of geological materials

    International Nuclear Information System (INIS)

    Mustapha, A.O.; Patel, J.P.; Rathore, I.V.S.; Hashim, N.O.; Otwoma, D.

    2004-01-01

    A NaI(Tl)-based gamma spectrometer for the analysis of geological materials was calibrated using the IAEA reference materials RGU-1, RGTH-1 and RGK-1. To simulate typical geological samples, two additional standards were prepared from aliquots of the three reference materials. The reproducibility of the instrument calibration factors (CFs) was tested by repeated measurements of the pure IAEA reference materials and the mixed samples in a reproducible counting geometry. The results were analysed using a two-way classification analysis of variance; it was found that the variance in the CFs is significantly higher between standards than it is between measurements. Allowance should be made for this when estimating uncertainties in measurements with the NaI(Tl) spectrometers

  1. Development of low level 226Ra analysis for live fish using gamma-ray spectrometry

    Science.gov (United States)

    Chandani, Z.; Prestwich, W. V.; Byun, S. H.

    2017-06-01

    A low level 226Ra analysis method for live fish was developed using a 4π NaI(Tl) gamma-ray spectrometer. In order to find out the best algorithm for accomplishing the lowest detection limit, the gamma-ray spectrum from a 226Ra point was collected and nine different methods were attempted for spectral analysis. The lowest detection limit of 0.99 Bq for an hour counting occurred when the spectrum was integrated in the energy region of 50-2520 keV. To extend 226Ra analysis to live fish, a Monte Carlo simulation model with a cylindrical fish in a water container was built using the MCNP code. From simulation results, the spatial distribution of the efficiency and the efficiency correction factor for the live fish model were determined. The MCNP model will be able to be conveniently modified when a different fish or container geometry is employed as fish grow up in real experiments.

  2. Field {gamma}-ray spectrometry on the Vulcano island (Aeolian Arc, Italy)

    Energy Technology Data Exchange (ETDEWEB)

    Chiozzi, P.; Pasquale, V.; Russo, D.; Verdoya, M. [Dipartimento di Scienze della Terra, Universita di Genova, Genoa (Italy); De Felice, P. [Istituto Nazionale di Metrologica delle Radiazioni Ionizzanti ENEA, Dipartimento Ambiente, Centro Ricerche Casaccia, Rome (Italy)

    1999-08-01

    In situ NaI(Tl) {gamma}-ray spectrometric measurements on the Vulcano island show that the magmatic evolution of the main structural units is reflected by the uranium, thorium and potassium concentrations. The results allowed us to delineate two temporal and radiometric districts. The older district comprises lava flows and pyroclastics of mafic composition forming the whole southern part of the island, with an equivalent uranium concentration and an eTh/eU ratio ranging, on average, from 2.9 to 3.4 ppm and from 2.4 to 4.1, respectively. Rocks of the younger district, ranging from leucitic tephritic and trachytic to rhyolitic composition, show higher K contents (about 6%) and more variable eTh/eU ratios (2.4-6.1)

  3. Field γ-ray spectrometry on the Vulcano island (Aeolian Arc, Italy)

    International Nuclear Information System (INIS)

    Chiozzi, P.; Pasquale, V.; Russo, D.; Verdoya, M.; De Felice, P.

    1999-01-01

    In situ NaI(Tl) γ-ray spectrometric measurements on the Vulcano island show that the magmatic evolution of the main structural units is reflected by the uranium, thorium and potassium concentrations. The results allowed us to delineate two temporal and radiometric districts. The older district comprises lava flows and pyroclastics of mafic composition forming the whole southern part of the island, with an equivalent uranium concentration and an eTh/eU ratio ranging, on average, from 2.9 to 3.4 ppm and from 2.4 to 4.1, respectively. Rocks of the younger district, ranging from leucitic tephritic and trachytic to rhyolitic composition, show higher K contents (about 6%) and more variable eTh/eU ratios (2.4-6.1)

  4. Mass Spectrometry Imaging of Drugs of Abuse in Hair.

    Science.gov (United States)

    Flinders, Bryn; Cuypers, Eva; Porta, Tiffany; Varesio, Emmanuel; Hopfgartner, Gérard; Heeren, Ron M A

    2017-01-01

    Hair testing is a powerful tool routinely used for the detection of drugs of abuse. The analysis of hair is highly advantageous as it can provide prolonged drug detectability versus that in biological fluids and chronological information about drug intake based on the average growth of hair. However, current methodology requires large amounts of hair samples and involves complex time-consuming sample preparation followed by gas or liquid chromatography coupled with mass spectrometry. Mass spectrometry imaging is increasingly being used for the analysis of single hair samples, as it provides more accurate and visual chronological information in single hair samples.Here, two methods for the preparation of single hair samples for mass spectrometry imaging are presented.The first uses an in-house built cutting apparatus to prepare longitudinal sections, the second is a method for embedding and cryo-sectioning hair samples in order to prepare cross-sections all along the hair sample.

  5. Proceedings of twelfth ISMAS symposium cum workshop on mass spectrometry

    International Nuclear Information System (INIS)

    Alamelu, D.; Jaison, P.G.; Aggarwal, S.K.

    2007-03-01

    Mass Spectrometry is an important analytical tool and has encompassed almost all branches of science and technology including Agricultural, biology, Chemistry, Earth sciences, environment, Forensic Science, Medical Sciences, Hydrology, Nuclear Technology, Oceanography, Physics etc. Recent advancements in the instrumentation of Mass Spectrometry have further strengthened its role for various applications. It is indeed a matter of great pleasure to present this special Issue of ISMAS Bulletin which is brought out on the occasion of the 12th ISMAS Symposium cum Workshop on Mass spectrometry (12th ISMAS-WS 2007) being held at Cidade-de-Goa, Dona Paula, Goa from March 25 to 30, 2007 in association with National Institute of Oceanography, Goa. This Symposium cum Workshop is co-sponsored by Scientific Departments of Government of India. Papers relevant to INIS are indexed separately

  6. Radio-frequency glow discharge spectrometry: A critical review

    International Nuclear Information System (INIS)

    Winchester, Michael R.; Payling, Richard

    2004-01-01

    This paper presents a critical review of analytical radio frequency glow discharge spectrometry (rf-GDS). The historical foundations of rf-GDS are described, and current knowledge of the fundamental physics of analytical rf glow discharges is discussed. Additionally, instrumentation, methodologies, and applications of rf glow discharge optical emission spectrometry (rf-GDOES) and mass spectrometry (rf-GDMS) are reviewed. Although other rf-GDS techniques have appeared [e.g. rf glow discharge atomic absorption spectrophotometry (rf-GDAAS)], the emphasis is placed upon rf-GDOES and rf-GDMS, because they have received by far the most interest from analytical chemical metrologists. This review also provides explanations of some developments that are needed for further progress in the field of analytical rf-GDS

  7. Paradigms in isotope dilution mass spectrometry for elemental speciation analysis

    International Nuclear Information System (INIS)

    Meija, Juris; Mester, Zoltan

    2008-01-01

    Isotope dilution mass spectrometry currently stands out as the method providing results with unchallenged precision and accuracy in elemental speciation. However, recent history of isotope dilution mass spectrometry has shown that the extent to which this primary ratio measurement method can deliver accurate results is still subject of active research. In this review, we will summarize the fundamental prerequisites behind isotope dilution mass spectrometry and discuss their practical limits of validity and effects on the accuracy of the obtained results. This review is not to be viewed as a critique of isotope dilution; rather its purpose is to highlight the lesser studied aspects that will ensure and elevate current supremacy of the results obtained from this method

  8. High efficiency nebulization for helium inductively coupled plasma mass spectrometry

    International Nuclear Information System (INIS)

    Jorabchi, Kaveh; McCormick, Ryan; Levine, Jonathan A.; Liu Huiying; Nam, S.-H.; Montaser, Akbar

    2006-01-01

    A pneumatically-driven, high efficiency nebulizer is explored for helium inductively coupled plasma mass spectrometry. The aerosol characteristics and analyte transport efficiencies of the high efficiency nebulizer for nebulization with helium are measured and compared to the results obtained with argon. Analytical performance indices of the helium inductively coupled plasma mass spectrometry are evaluated in terms of detection limits and precision. The helium inductively coupled plasma mass spectrometry detection limits obtained with the high efficiency nebulizer at 200 μL/min are higher than those achieved with the ultrasonic nebulizer consuming 2 mL/min solution, however, precision is generally better with high efficiency nebulizer (1-4% vs. 3-8% with ultrasonic nebulizer). Detection limits with the high efficiency nebulizer at 200 μL/min solution uptake rate approach those using ultrasonic nebulizer upon efficient desolvation with a heated spray chamber followed by a Peltier-cooled multipass condenser

  9. Laser desorption mass spectrometry for biomolecule detection and its applications

    Science.gov (United States)

    Winston Chen, C. H.; Sammartano, L. J.; Isola, N. R.; Allman, S. L.

    2001-08-01

    During the past few years, we developed and used laser desorption mass spectrometry for biomolecule detections. Matrix-assisted laser desorption/ionization (MALDI) was successfully used to detect DNA fragments with the size larger than 3000 base pairs. It was also successfully used to sequence DNA with both enzymatic and chemical degradation methods to produce DNA ladders. We also developed MALDI with fragmentation for direct DNA sequencing for short DNA probes. Since laser desorption mass spectrometry for DNA detection has the advantages of fast speed and no need of labeling, it has a great potential for molecular diagnosis for disease and person identification by DNA fingerprinting. We applied laser desorption mass spectrometry to succeed in the diagnosis of cystic fibrosis and several other nerve degenerative diseases such as Huntington's disease. We also succeeded in demonstrating DNA typing for forensic applications.

  10. Laser desorption mass spectrometry for biomolecule detection and its applications

    International Nuclear Information System (INIS)

    Winston Chen, C.H.; Allman, S.L.; Sammartano, L.J.; Isola, N.R.

    2001-01-01

    During the past few years, we developed and used laser desorption mass spectrometry for biomolecule detections. Matrix-assisted laser desorption/ionization (MALDI) was successfully used to detect DNA fragments with the size larger than 3000 base pairs. It was also successfully used to sequence DNA with both enzymatic and chemical degradation methods to produce DNA ladders. We also developed MALDI with fragmentation for direct DNA sequencing for short DNA probes. Since laser desorption mass spectrometry for DNA detection has the advantages of fast speed and no need of labeling, it has a great potential for molecular diagnosis for disease and person identification by DNA fingerprinting. We applied laser desorption mass spectrometry to succeed in the diagnosis of cystic fibrosis and several other nerve degenerative diseases such as Huntington's disease. We also succeeded in demonstrating DNA typing for forensic applications

  11. Further development of IDGS: Isotope dilution gamma-ray spectrometry

    International Nuclear Information System (INIS)

    Li, T.K.; Parker, J.L.; Kuno, Y.; Sato, S.; Kamata, M.; Akiyama, T.

    1991-01-01

    The isotope dilution gamma-ray spectrometry (IDGS) technique for determining the plutonium concentration and isotopic composition of highly radioactive spent-fuel dissolver solutions has been further developed. Both the sample preparation and the analysis have been improved. The plutonium isotopic analysis is based on high-resolution, low-energy gamma-ray spectrometry. The plutonium concentration in the dissolver solutions then is calculated from the measured isotopic differences among the spike, the dissolver solution, and the spiked dissolver solution. Plutonium concentrations and isotopic compositions of dissolver solutions analyzed from this study agree well with those obtained by traditional isotope dilution mass spectrometry (IDMS) and are consistent with the first IDGS experimental result. With the current detector efficiency, sample size, and a 100-min count time, the estimated precision is ∼0.5% for 239 Pu and 240 Pu isotopic analyses and ∼1% for the plutonium concentration analysis. 5 refs., 2 figs., 7 tabs

  12. Atomic fluorescence spectrometry with the inductively coupled plasma

    International Nuclear Information System (INIS)

    Omenetto, N.; Winefordner, J.D.

    1987-01-01

    Atomic fluorescence spectrometry (AFS) is based on the radiational activation of atoms and ions produced in a suitable atomizer (ionizer) and the subsequent measurement of the resulting radiational deactivation, called fluorescence. Atomic fluorescence spectrometry has been of considerable interest to researchers in atomic spectrometry because of its use for both analytical and diagnostic purposes. Unfortunately, the analytical applications of AFS have suffered from the lack of commercial instrumentation until the recent marketing of the Baird multiple-element, hollow cathode lamp-excited inductively coupled plasma system. This chapter is concerned strictly with the use of the inductively coupled plasma (ICP) as a cell and as a source for AFS. Many of the major references concerning the ICP in analytical AFS are categorized in Table 9.1, along with several reviews and diagnostical studies. For more detailed discussions of the fundamental aspects of AFS, the reader is referred to previous reviews

  13. Detector calibration for in-situ gamma ray spectrometry

    CERN Document Server

    Balea, G

    2002-01-01

    The power in the technique of in-situ spectrometry lies in the fact that a detector placed on ground measures gamma radiation from sources situated over an area of several hundred square meters. The 'field of view' for the detector would be larger for high energy radiation sources and for sources closer to the soil surface. In contrast, a soil sample would represent an area of a few tens of hundreds of square centimeters. In practice, an effective characterization of a site would involve in-situ gamma ray spectrometry in conjunction with soil sampling. As part of an overall program, in-situ gamma ray spectrometry provides a means to assess the degree of contamination in areas during the course of operations in the field, thus guiding the investigator on where to collect samples. It can also substantially reduce the number of samples need to be collected and subsequently analyzed. (author)

  14. Plant trait detection with multi-scale spectrometry

    Science.gov (United States)

    Gamon, J. A.; Wang, R.

    2017-12-01

    Proximal and remote sensing using imaging spectrometry offers new opportunities for detecting plant traits, with benefits for phenotyping, productivity estimation, stress detection, and biodiversity studies. Using proximal and airborne spectrometry, we evaluated variation in plant optical properties at various spatial and spectral scales with the goal of identifying optimal scales for distinguishing plant traits related to photosynthetic function. Using directed approaches based on physiological vegetation indices, and statistical approaches based on spectral information content, we explored alternate ways of distinguishing plant traits with imaging spectrometry. With both leaf traits and canopy structure contributing to the signals, results exhibit a strong scale dependence. Our results demonstrate the benefits of multi-scale experimental approaches within a clear conceptual framework when applying remote sensing methods to plant trait detection for phenotyping, productivity, and biodiversity studies.

  15. Neutron spectrometry for reactor applications: status, limitations, and future directions

    International Nuclear Information System (INIS)

    Gold, R.

    1975-08-01

    The ability of ''state-of-the-art'' reactor neutron spectrometry to provide definitive environmental results required for high fluence radiation damage experiments is reviewed. A formal definition of the neutron component is presented as well as general considerations which accrue from both this definition and the existence of the mixed radiation field generally encountered in reactors. A description of four selected methods of reactor neutron spectrometry is included, namely Proton Recoil (PR) methods, Time-Of-Flight (TOF) methods, the 6 Li(n,α) 3 H coincidence method, and Multiple Foil Activation (MFA) methods. These selected methods are compared. Future requirements and directions for reactor neutron spectrometry are discussed. In particular, the needs of future CTR research are stressed and the He 4 - recoil proportional counter spectroscopy method is advanced as a means of meeting these future requirements. 50 references. (auth)

  16. Development of stereotactic mass spectrometry for brain tumor surgery.

    Science.gov (United States)

    Agar, Nathalie Y R; Golby, Alexandra J; Ligon, Keith L; Norton, Isaiah; Mohan, Vandana; Wiseman, Justin M; Tannenbaum, Allen; Jolesz, Ferenc A

    2011-02-01

    Surgery remains the first and most important treatment modality for the majority of solid tumors. Across a range of brain tumor types and grades, postoperative residual tumor has a great impact on prognosis. The principal challenge and objective of neurosurgical intervention is therefore to maximize tumor resection while minimizing the potential for neurological deficit by preserving critical tissue. To introduce the integration of desorption electrospray ionization mass spectrometry into surgery for in vivo molecular tissue characterization and intraoperative definition of tumor boundaries without systemic injection of contrast agents. Using a frameless stereotactic sampling approach and by integrating a 3-dimensional navigation system with an ultrasonic surgical probe, we obtained image-registered surgical specimens. The samples were analyzed with ambient desorption/ionization mass spectrometry and validated against standard histopathology. This new approach will enable neurosurgeons to detect tumor infiltration of the normal brain intraoperatively with mass spectrometry and to obtain spatially resolved molecular tissue characterization without any exogenous agent and with high sensitivity and specificity. Proof of concept is presented in using mass spectrometry intraoperatively for real-time measurement of molecular structure and using that tissue characterization method to detect tumor boundaries. Multiple sampling sites within the tumor mass were defined for a patient with a recurrent left frontal oligodendroglioma, World Health Organization grade II with chromosome 1p/19q codeletion, and mass spectrometry data indicated a correlation between lipid constitution and tumor cell prevalence. The mass spectrometry measurements reflect a complex molecular structure and are integrated with frameless stereotaxy and imaging, providing 3-dimensional molecular imaging without systemic injection of any agents, which can be implemented for surgical margins delineation of

  17. New approaches for metabolomics by mass spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Vertes, Akos [George Washington Univ., Washington, DC (United States)

    2017-07-10

    Small molecules constitute a large part of the world around us, including fossil and some renewable energy sources. Solar energy harvested by plants and bacteria is converted into energy rich small molecules on a massive scale. Some of the worst contaminants of the environment and compounds of interest for national security also fall in the category of small molecules. The development of large scale metabolomic analysis methods lags behind the state of the art established for genomics and proteomics. This is commonly attributed to the diversity of molecular classes included in a metabolome. Unlike nucleic acids and proteins, metabolites do not have standard building blocks, and, as a result, their molecular properties exhibit a wide spectrum. This impedes the development of dedicated separation and spectroscopic methods. Mass spectrometry (MS) is a strong contender in the quest for a quantitative analytical tool with extensive metabolite coverage. Although various MS-based techniques are emerging for metabolomics, many of these approaches include extensive sample preparation that make large scale studies resource intensive and slow. New ionization methods are redefining the range of analytical problems that can be solved using MS. This project developed new approaches for the direct analysis of small molecules in unprocessed samples, as well as pushed the limits of ultratrace analysis in volume limited complex samples. The projects resulted in techniques that enabled metabolomics investigations with enhanced molecular coverage, as well as the study of cellular response to stimuli on a single cell level. Effectively individual cells became reaction vessels, where we followed the response of a complex biological system to external perturbation. We established two new analytical platforms for the direct study of metabolic changes in cells and tissues following external perturbation. For this purpose we developed a novel technique, laser ablation electrospray

  18. Correction factors for photon spectrometry in nuclear parameters study

    International Nuclear Information System (INIS)

    Patrao, Karla Cristina de Souza

    2004-10-01

    The goal of this work was the determination, using metrologic severity, the factors of correction for coincidences XX, Xγ and γγ and the factors of transference of efficiency for use in gamma spectrometry. On this way, it was carried through by determination of nuclear parameters of a nuclide used in medicine diagnostic ( 201 Tl) and the standardization of two environmental samples, of regular and irregular geometry, proceeding from the residual (ashes and slag) from the nuclear industry. The results shows that this adopted methodology is valid, and it allows its application for many different nuclides, including complex decay schema nuclides, using only photons spectrometry techniques on semiconductor detectors. (author)

  19. Radiogas chromatography mass spectrometry in the selected ion monitoring mode

    International Nuclear Information System (INIS)

    Doerfler, D.L.; Rosenblum, E.R.; Malloy, J.M.; Naworal, J.D.; McManus, I.R.; Campbell, I.M.

    1980-01-01

    The value of selected ion monitoring in analyzing biological radio isotope incorporation experiments by radiogas chromatography mass spectrometry is illustrated with reference to the biosynthesis of the mycotoxin mycophenolic acid in Penicillium brevicompactum and the mode of action of the anticholesterolemic drug 20,25-diazacholesterol. Both examples used 1-[ 14 C]acetate precursors. It is shown that the increased sensitivity and specificity of the selected ion monitoring mode detector permits straightforward detection and identification of the relatively small cellular pools associated with metabolic intermediates. The computer program RADSIM is described. Problems that still exist in using radiogas gas chromatography mass spectrometry technology to analyse isotope incorporation experiments are discussed. (author)

  20. Towards airborne nanoparticle mass spectrometry with nanomechanical string resonators

    DEFF Research Database (Denmark)

    Schmid, Silvan; Kurek, Maksymilian; Boisen, Anja

    2013-01-01

    airborne nanoparticle sensors. Recently, nanomechanical mass spectrometry was established. One of the biggest challenges of nanomechanical sensors is the low efficiency of diffusion-based sampling. We developed an inertial-based sampling method that enables the efficient sampling of airborne nanoparticles...... mode. Mass spectrometry of airborne nanoparticles requires the simultaneous operation in the first and second mode, which can be implemented in the transduction scheme of the resonator. The presented results lay the cornerstone for the realization of a portable airborne nanoparticle mass spectrometer....

  1. Use of mass spectrometry for study of coordination compounds

    International Nuclear Information System (INIS)

    Gehrbehlehu, N.V.; Indrichan, K.M.

    1981-01-01

    A review on mass-spectrometry of coordination compounds including the works published up to 1979 inclusive is provided. Mainly the products of metals with bi- and tetradentate ligands are considered using the method. Mo and Be carboxylates for which molecular ions lines are found in mass-spectra are studied. The study of mass-spectra for VO chelates with thiosemicarbazone of salicyl aldehyde is carried out. Application of the mass-spectrometry method permits to establish the mass of coordination compounds, the structure of complexes, dentate structure and the way of ligand coordination, the bond strength [ru

  2. In-pile gamma spectrometry and irradiation control at Osiris

    International Nuclear Information System (INIS)

    Farny, G.; Destot, M.; Corre, J.; Texier, D.; Faugere, J.L.; Mouchnino, M.

    1975-01-01

    A new gamma spectrometry facility is available near Osiris reactor core, at Saclay. This device enables nuclear fuels to be examined in loops or capsules all along their irradiation, a few minutes being sufficient to transfer the fuel from the irradiation place to the measurement bench. So, spacelike and timelike history of a lot of fission products, especially short-lived radionuclides, can be observed. Using such in-pile spectrometry device, of original design, allows to avoid radioactive decay corrections and the risks of any information less. Performance of the device is given together with some preliminary results and their interpretation [fr

  3. The Utilization of Background Spectrum to Calibrate Gamma Spectrometry

    International Nuclear Information System (INIS)

    Mahrouka, M. M.; Mutawa, A. M.

    2004-01-01

    Many developed countries have very poor reference standards to calibrate their nuclear instrumentations or may find some difficulties to obtain a reference standard. In this work a simple way for Gamma spectrometry calibration was developed. The method depends on one reference point and additional points from the background. The two derived equations were applied to the analyses of radioactive nuclides in soil and liquid samples prepared by IAEA laboratories through AL MERA Project. The results showed the precision of the methodology used, as well as, the possibility of using some points in the background spectrum as a replacement for reference standards of Gamma spectrometry calibration. (authors)

  4. Analysis of chirality by femtosecond laser ionization mass spectrometry.

    Science.gov (United States)

    Horsch, Philipp; Urbasch, Gunter; Weitzel, Karl-Michael

    2012-09-01

    Recent progress in the field of chirality analysis employing laser ionization mass spectrometry is reviewed. Emphasis is given to femtosecond (fs) laser ionization work from the author's group. We begin by reviewing fundamental aspects of determining circular dichroism (CD) in fs-laser ionization mass spectrometry (fs-LIMS) discussing an example from the literature (resonant fs-LIMS of 3-methylcyclopentanone). Second, we present new data indicating CD in non-resonant fs-LIMS of propylene oxide. Copyright © 2012 Wiley Periodicals, Inc., A Wiley Company.

  5. Issues and opportunities in accelerator mass spectrometry for stable isotopes.

    Science.gov (United States)

    Matteson, Sam

    2008-01-01

    Accelerator mass spectrometry (AMS) has developed in the last 30 years many notable applications to the spectrometry of radioisotopes, particularly in radiocarbon dating. The instrumentation science of trace element AMS (TEAMS) that analyzes stable isotopes, also called Accelerator SIMS or MegaSIMS, while unique in many features, has also shared in many of these significant advances and has pushed TEAMS sensitivity to concentration levels surpassing many competing mass spectroscopic technologies. This review examines recent instrumentation developments, the capabilities of the new instrumentation and discernable trends for future development. Copyright 2008 Wiley Periodicals, Inc.

  6. Native Mass Spectrometry in Fragment-Based Drug Discovery.

    Science.gov (United States)

    Pedro, Liliana; Quinn, Ronald J

    2016-07-28

    The advent of native mass spectrometry (MS) in 1990 led to the development of new mass spectrometry instrumentation and methodologies for the analysis of noncovalent protein-ligand complexes. Native MS has matured to become a fast, simple, highly sensitive and automatable technique with well-established utility for fragment-based drug discovery (FBDD). Native MS has the capability to directly detect weak ligand binding to proteins, to determine stoichiometry, relative or absolute binding affinities and specificities. Native MS can be used to delineate ligand-binding sites, to elucidate mechanisms of cooperativity and to study the thermodynamics of binding. This review highlights key attributes of native MS for FBDD campaigns.

  7. Quantitating subcellular metabolism with multi-isotope imaging mass spectrometry

    OpenAIRE

    Steinhauser, Matthew L.; Bailey, Andrew; Senyo, Samuel E.; Guillermier, Christelle; Perlstein, Todd S.; Gould, Alex P.; Lee, Richard T.; Lechene, Claude P.

    2012-01-01

    Mass spectrometry with stable isotope labels has been seminal in discovering the dynamic state of living matter 1,2 but is limited to bulk tissues or cells. We developed multi-isotope imaging mass spectrometry (MIMS) that allowed us to view and measure stable isotope incorporation with sub-micron resolution 3,4 . Here we apply MIMS to diverse organisms, including Drosophila, mice, and humans. We test the “immortal strand hypothesis,” which predicts that during asymmetric stem cell division ch...

  8. Determination of uranium in seawater by fluorescence spectrometry

    International Nuclear Information System (INIS)

    Kawashima, Toshi; Kawakubo, Senkichi; Minegishi, Hisako.

    1984-01-01

    A Fluorescence spectrometry for the determination of uranium in seawater has been developed. Anion exchange separation of uranium from seawater followed by preparation of NaF-carbonate cake and by spectrometry for ultraviolet ray excited fluorescence of uranium on the fluoride host provide the trace determinaton of uranium at the subnano gram level. Anion exchange behavior, excitation-emission behavior of the uranium on the host and effects of foreign ions to the fluorescence have been presented. Appling the method to 1 ml of seawater 3 ppb of uranium has been determined. (author)

  9. Methodology for determination of activity of radionuclides by gamma spectrometry

    International Nuclear Information System (INIS)

    Fragoso, Maria da Conceicao de Farias; Oliveira, Victor Rogerio S. de; Oliveira, Mercia L.; Lima, Fernando Roberto de Andrade

    2014-01-01

    Due to the growth in the number of procedures that make use of the positron emission tomography (PET), there is a need for standard solutions for the calibration of the systems used for the measurement of the PET radiopharmaceutical (activimeter) in radiopharmacies and in nuclear medicine services. Among the existing alternatives for the standardization of radioactive sources, the method known as gamma spectrometry is widely used for short-lived radionuclides. The purpose of this study was to implement the methodology for standardization of the 18 F solutions by gamma spectrometry at the Regional Center for Nuclear Sciences of the Northeast (CRCN-NE/CNEN-NE), Brazil. (author)

  10. Major roles for minor bacterial lipids identified by mass spectrometry.

    Science.gov (United States)

    Garrett, Teresa A

    2017-11-01

    Mass spectrometry of lipids, especially those isolated from bacteria, has ballooned over the past two decades, affirming in the process the complexity of the lipidome. With this has come the identification of new and interesting lipid structures. Here is an overview of several novel lipids, from both Gram-negative and Gram-positive bacteria with roles in health and disease, whose structural identification was facilitated using mass spectrometry. This article is part of a Special Issue entitled: Bacterial Lipids edited by Russell E. Bishop. Copyright © 2016 Elsevier B.V. All rights reserved.

  11. Coupling Front-End Separations, Ion Mobility Spectrometry, and Mass Spectrometry For Enhanced Multidimensional Biological and Environmental Analyses

    Science.gov (United States)

    Zheng, Xueyun; Wojcik, Roza; Zhang, Xing; Ibrahim, Yehia M.; Burnum-Johnson, Kristin E.; Orton, Daniel J.; Monroe, Matthew E.; Moore, Ronald J.; Smith, Richard D.; Baker, Erin S.

    2017-01-01

    Ion mobility spectrometry (IMS) is a widely used analytical technique for rapid molecular separations in the gas phase. Though IMS alone is useful, its coupling with mass spectrometry (MS) and front-end separations is extremely beneficial for increasing measurement sensitivity, peak capacity of complex mixtures, and the scope of molecular information available from biological and environmental sample analyses. In fact, multiple disease screening and environmental evaluations have illustrated that the IMS-based multidimensional separations extract information that cannot be acquired with each technique individually. This review highlights three-dimensional separations using IMS-MS in conjunction with a range of front-end techniques, such as gas chromatography, supercritical fluid chromatography, liquid chromatography, solid-phase extractions, capillary electrophoresis, field asymmetric ion mobility spectrometry, and microfluidic devices. The origination, current state, various applications, and future capabilities of these multidimensional approaches are described in detail to provide insight into their uses and benefits. PMID:28301728

  12. Coupling Front-End Separations, Ion Mobility Spectrometry, and Mass Spectrometry For Enhanced Multidimensional Biological and Environmental Analyses

    Energy Technology Data Exchange (ETDEWEB)

    Zheng, Xueyun; Wojcik, Roza; Zhang, Xing; Ibrahim, Yehia M.; Burnum-Johnson, Kristin E.; Orton, Daniel J.; Monroe, Matthew E.; Moore, Ronald J.; Smith, Richard D.; Baker, Erin M.

    2017-06-12

    Ion mobility spectrometry (IMS) is a widely used analytical technique for rapid molecular separations in the gas phase. IMS alone is useful, but its coupling with mass spectrometry (MS) and front-end separations has been extremely beneficial for increasing measurement sensitivity, peak capacity of complex mixtures, and the scope of molecular information in biological and environmental sample analyses. Multiple studies in disease screening and environmental evaluations have even shown these IMS-based multidimensional separations extract information not possible with each technique individually. This review highlights 3-dimensional separations using IMS-MS in conjunction with a range of front-end techniques, such as gas chromatography (GC), supercritical fluid chromatography (SFC), liquid chromatography (LC), solid phase extractions (SPE), capillary electrophoresis (CE), field asymmetric ion mobility spectrometry (FAIMS), and microfluidic devices. The origination, current state, various applications, and future capabilities for these multidimensional approaches are described to provide insight into the utility and potential of each technique.

  13. Metrological characterization of the numerical system Adonis for gamma spectrometry; Caracterisation metrologique du systeme de spectrometrie gamma numerique Adonis

    Energy Technology Data Exchange (ETDEWEB)

    Plagnard, J.; Morel, J.; Tran Tuan, A

    2005-07-01

    In gamma spectrometry, new acquisition systems based on digital processing of the signals are now available on the market. In order to determine their performances at high count rates, The CEA-LNHB (Commissariat a l'Energie Atomique - Laboratoire National Henri Becquerel) has tested several of these equipments.. These tests have clearly shown that the performances announced by the manufacturers were generally not met. At this point, it was interesting to include in these tests, the system ADONIS (Atelier de Developpement Numerique pour l'Instrumentation en Spectrometrie), which is the new gamma spectrometry system, developed by the CEA-SIAR (Service d'Instrumentation et d'Application des Rayonnements). (authors)

  14. ENVIRONMENTAL ANALYSIS BY AB INITIO QUANTUM MECHANICAL COMPUTATION AND GAS CHROMATOGRAPHY/FOURIER TRANSFORM INFRARED SPECTROMETRY.

    Science.gov (United States)

    Computational chemistry, in conjunction with gas chromatography/mass spectrometry/Fourier transform infrared spectrometry (GC/MS/FT-IR), was used to tentatively identify seven tetrachlorobutadiene (TCBD) isomers detected in an environmental sample. Computation of the TCBD infrare...

  15. A low-cost vaporization-atomization system for atomic absorption spectrometry

    International Nuclear Information System (INIS)

    Bruhn F, C.G.; Ambiado V, F.; Woerner V, R.

    1990-01-01

    A low-cost vaporization-atomization system for atomic absorption spectrometry is developed as an alternative to the use of a graphite furnace in electrothermal atomic absorption spectrometry. (Author)

  16. Specialized Gas Chromatography--Mass Spectrometry Systems for Clinical Chemistry.

    Science.gov (United States)

    Gochman, Nathan; And Others

    1979-01-01

    A discussion of the basic design and characteristics of gas chromatography-mass spectrometry systems used in clinical chemistry. A comparison of three specific systems: the Vitek Olfax IIA, Hewlett-Packard HP5992, and Du Pont DP-102 are included. (BB)

  17. Role of mass spectrometry in nuclear forensic science

    International Nuclear Information System (INIS)

    Joseph, M.; Sivaraman, N.

    2016-01-01

    The present talk will focus on the role of mass spectrometry in NFS in general; besides that, the various chromatographic methods developed towards separation of actinides and lanthanide fission products and characterization of dissolver solutions of nuclear reactor fuels using TIMS and some applications of using ICP-MS as well

  18. Chemical analysis of steel by optical emission spectrometry

    International Nuclear Information System (INIS)

    Hayakawa, M.O.; Kajita, T.; Jeszensky, G.

    1981-01-01

    The development of the chemical analysis for special steels by optical emission spectrometry direct reading method with computer, at the Siderurgica N.S. Aparecida S.A. is presented. Results are presented for the low alloy steels and high speed steel. Also, the contribution of this method to the special steel preparation is commented. (Author) [pt

  19. Identification of Secreted Candida Proteins Using Mass Spectrometry

    NARCIS (Netherlands)

    Gómez-Molero, E.; Dekker, H.L.; de Boer, A.D.; de Groot, P.W.; Calderone, R.; Cihlar, R.

    2016-01-01

    Analysis of fungal secretomes using mass spectrometry is a useful technique in cell biology. Knowledge of the secretome of a human fungal pathogen may yield important information of host-pathogen interactions and may be useful for identifying vaccines candidates or diagnostic markers for antifungal

  20. Set-up of an alpha-spectrometry system

    International Nuclear Information System (INIS)

    Calicchia, A.

    1976-01-01

    Principle of operation of alpha-spectrometry system is described, using a solid state detector, which allows to precisely determine sample's activity and specify alpha-emitting radionuclides. Measurements which allow to define system performances are shown, that is energy resolution and real sensitivity of spectrometer

  1. Digital approach to high rate gamma-ray spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Korolczuk, Stefan; Mianowski, Slawomir; Rzadkiewicz, Jacek; Sibczynski, Pawel; Swiderski, Lukasz; Szewinski, Jaroslaw; Zychor, Izabella [Narodowe Centrum Badan Jadrowych (NCBJ), 05-400 Otwock, (Poland)

    2015-07-01

    Basic concepts and preliminary results of creating high rate digital spectrometry system using efficient ADCs and latest FPGA are presented as well as a comparison with commercially available devices. The possibility to use such systems, coupled to scintillators, in plasma experiments is discussed. (authors)

  2. Mass Spectrometry Imaging, an Emerging Technology in Neuropsychopharmacology

    Science.gov (United States)

    Shariatgorji, Mohammadreza; Svenningsson, Per; Andrén, Per E

    2014-01-01

    Mass spectrometry imaging is a powerful tool for directly determining the distribution of proteins, peptides, lipids, neurotransmitters, metabolites and drugs in neural tissue sections in situ. Molecule-specific imaging can be achieved using various ionization techniques that are suited to different applications but which all yield data with high mass accuracies and spatial resolutions. The ability to simultaneously obtain images showing the distributions of chemical species ranging from metal ions to macromolecules makes it possible to explore the chemical organization of a sample and to correlate the results obtained with specific anatomical features. The imaging of biomolecules has provided new insights into multiple neurological diseases, including Parkinson's and Alzheimer's disease. Mass spectrometry imaging can also be used in conjunction with other imaging techniques in order to identify correlations between changes in the distribution of important chemical species and other changes in the properties of the tissue. Here we review the applications of mass spectrometry imaging in neuroscience research and discuss its potential. The results presented demonstrate that mass spectrometry imaging is a useful experimental method with diverse applications in neuroscience. PMID:23966069

  3. On-Line Synthesis and Analysis by Mass Spectrometry

    Science.gov (United States)

    Bain, Ryan M.; Pulliam, Christopher J.; Raab, Shannon A.; Cooks, R. Graham

    2015-01-01

    In this laboratory experiment, students learn how to use ESI to accelerate chemical synthesis and to couple it with on-line mass spectrometry for structural analysis. The Hantzsch synthesis of symmetric 1,4-dihydropyridines is a classic example of a one-pot reaction in which multiple intermediates can serve to indicate the progress of the reaction…

  4. Biomedical applications of mass spectrometry. Clinical uses of stable isotopes

    International Nuclear Information System (INIS)

    Krahmer, U.I.; McCloskey, J.A.

    1978-01-01

    The review covers typical or important examples of stable isotope usage in clinical fields during the period since the last triennial mass spectrometry conference in 1973. Items are included which involve uses of stable isotopes in human or clinically oriented studies, including measurements carried out on materials of human origin. 163 references. (U.K.)

  5. Practical aspects and trends in analytical organic mass spectrometry

    International Nuclear Information System (INIS)

    Schlunegger, U.P.

    1981-01-01

    Proceeding from the fundamentals of mass spectrometry (MS), some more recent developments of analytical organic MS are shown in comparison with conventional MS. Sections are headed: the vacuum, production of ions in the mass spectrometer, ions in the analyzer of a mass spectrometer, general considerations, practice of modern MS: selected examples

  6. Recent research and progress of laser mass spectrometry

    International Nuclear Information System (INIS)

    Li Jinying; Wang Fan; Zhao Yonggang; Xiao Guoping; Guo Dongfa; Cui Haiping

    2012-01-01

    The progress of laser mass spectrometry (LMS) was introduced. Its history and principle characteristics were reviewed. The research and applications of LMS in geology, mining, organics, biochemistry, environment and nuclear industry were given. The trend of LMS in the future was outlined, and the main issue and the available solutions were discussed. (authors)

  7. Advances in characterizing ubiquitylation sites by mass spectrometry

    DEFF Research Database (Denmark)

    Sylvestersen, K.B.; Young, C.; Nielsen, M.L.

    2013-01-01

    of ubiquitylation is a two-fold challenge that involves the mapping of ubiquitylation sites and the determination of ubiquitin chain topology. This review focuses on the technical advances in the mass spectrometry-based characterization of ubiquitylation sites, which have recently involved the large...

  8. The use of mass spectrometry in peptide chemistry

    NARCIS (Netherlands)

    Leclercq, P.A.; White, P.A.; Hägele, K.; Desiderio, D.M.; Meienhofer, J.

    1972-01-01

    A review with 16 refs. Methods are detailed for derivatizing peptides (mg quantities) in order to provide sufficient volatility for mass spectrometry (at least 10-5 mm vapor pressure at 300 Deg is required). Three steps are used in producing the desired derivs.: (a) arginine side chains are

  9. Accelerator mass spectrometry-current status in techniques and applications

    International Nuclear Information System (INIS)

    Imamura, Mineo; Nagai, Hisao; Kobayashi, Koichi.

    1991-01-01

    Accelerator mass spectrometry (AMS) is the mass spectrometry by incorporating an accelerator. After samples are ionized, they are accelerated to a certain energy, and mass, energy, nuclear charge (atomic number) are distinguished, and ion counting is made one by one with a heavy ion detector. For the measurement of long half-life radioisotopes, mass spectrometry has been used because of the high sensitivity, but in low energy mass spectrometry, there are the difficulties due to the mixing of the molecular ions having nearly same mass and the existence of isobars. One of the methods solving these difficulties is an accelerator which enables background-free measurement. The progress of AMS is briefly described, and at present, it is carried out in about 30 facilities in the world. In AMS, the analysis is carried out in the order of the ionization of samples, the acceleration of beam, the electron stripping with a thin film, the sorting of the momentum and energy of beam and the identification of particles. The efficiency, sensitivity and accuracy of detection and the application are reported. (K.I.)

  10. Boundaries of mass resolution in native mass spectrometry

    NARCIS (Netherlands)

    Lössl, Philip|info:eu-repo/dai/nl/371559693; Snijder, Joost|info:eu-repo/dai/nl/338018328; Heck, Albert J R|info:eu-repo/dai/nl/105189332

    Over the last two decades, native mass spectrometry (MS) has emerged as a valuable tool to study intact proteins and noncovalent protein complexes. Studied experimental systems range from small-molecule (drug)-protein interactions, to nanomachineries such as the proteasome and ribosome, to even

  11. Gas chromatography mass spectrometry : key technology in metabolomics

    NARCIS (Netherlands)

    Koek, Maud Marijtje

    2009-01-01

    Metabolomics involves the unbiased quantitative and qualitative analysis of the complete set of metabolites present in cells, body fluids and tissues. Gas chromatography coupled to mass spectrometry (GC-MS) is very suitable for metabolomics analysis, as it combines high separation power with

  12. Fusion of mass spectrometry-based metabolomics data

    NARCIS (Netherlands)

    Smilde, Age K.; van der Werf, Mariët J.; Bijlsma, Sabina; van der Werff-van der Vat, Bianca J. C.; Jellema, Renger H.

    2005-01-01

    A general method is presented for combining mass spectrometry-based metabolomics data. Such data are becoming more and more abundant, and proper tools for fusing these types of data sets are needed. Fusion of metabolomics data leads to a comprehensive view on the metabolome of an organism or

  13. 226Ra determination in phosphogypsum by alpha-particle spectrometry

    International Nuclear Information System (INIS)

    Aguado, J.L.; Bolivar, J.P.; Garcia-Tenorio, R.

    1999-01-01

    A radiochemical method for 226 Ra determination by alpha-particle spectrometry in environmental samples has been developed in our laboratory. The method has been validated by measurements in samples with known concentrations of this radionuclide and it has been applied in studies related to 226 Ra behaviour in phosphogypsum (the main by-product of producing phosphoric acid from phosphate rocks). (author)

  14. Structural analyses of sucrose laurate regioisomers by mass spectrometry techniques

    DEFF Research Database (Denmark)

    Lie, Aleksander; Stensballe, Allan; Pedersen, Lars Haastrup

    2015-01-01

    6- And 6′-O-lauroyl sucrose were isolated and analyzed by matrix-assisted laser desorption/ionisation (MALDI) time-of-flight (TOF) mass spectrometry (MS), Orbitrap high-resolution (HR) MS, and electrospray-ionization (ESI) tandem mass spectrometry (MS/MS). The analyses aimed to explore the physic......6- And 6′-O-lauroyl sucrose were isolated and analyzed by matrix-assisted laser desorption/ionisation (MALDI) time-of-flight (TOF) mass spectrometry (MS), Orbitrap high-resolution (HR) MS, and electrospray-ionization (ESI) tandem mass spectrometry (MS/MS). The analyses aimed to explore.......8, respectively, and Orbitrap HRMS confirmed the mass of [M+Na]+ (m/z 547.2712). ESI-MS/MS on the precursor ion [M+Na]+ resulted in product ion mass spectra showing two high-intensity signals for each sample. 6-O-Lauroyl sucrose produced signals located at m/z 547.27 and m/z 385.21, corresponding to the 6-O...

  15. AM1 and electron impact mass spectrometry study of the ...

    African Journals Online (AJOL)

    Recently, in electron impact mass spectrometry (EIMS), it has been found a good correlation between the fragmentation processes of coumarins and the electronic charges of the atoms of their skeleton. In this paper, the same analytical method has been applied to 4-acyl isochroman-1,3-diones, whose mass spectra had ...

  16. Application of total reflection X-ray fluorescence spectrometry for ...

    Indian Academy of Sciences (India)

    Applicability of total reflection X-ray fluorescence (TXRF) spectrometry for trace elemental analysis of rainwater samples was studied. The study was used to develop these samples as rainwater standards by the National University of Singapore (NUS). Our laboratory was one of the participants to use TXRF for this study.

  17. X-ray fluorescence spectrometry applied to soil analysis

    International Nuclear Information System (INIS)

    Salvador, Vera Lucia Ribeiro; Sato, Ivone Mulako; Scapin Junior, Wilson Santo; Scapin, Marcos Antonio; Imakima, Kengo

    1997-01-01

    This paper studies the X-ray fluorescence spectrometry applied to the soil analysis. A comparative study of the WD-XRFS and ED-XRFS techniques was carried out by using the following soil samples: SL-1, SOIL-7 and marine sediment SD-M-2/TM, from IAEA, and clay, JG-1a from Geological Survey of Japan (GSJ)

  18. Automatic α-spectrometry using surface barrier detectors

    International Nuclear Information System (INIS)

    Czarwinski, R.; Loessner, V.; Klucke, H.; Krause, J.

    1984-01-01

    A measurement system has been developed for the routine determination of transuranics in biosamples by α-spectrometry. It employs high-resolution surface-barrier detectors and can be operated automatically by means of an integrated CAMAC system. For 241 Am, the minimum detectable activity is 2.4 x 10 -3 Bq. (author)

  19. Discovery based and targeted Mass Spectrometry in farm animal proteomics

    DEFF Research Database (Denmark)

    Bendixen, Emøke

    2013-01-01

    for investigating farm animal biology. SRM is particularly important for validation biomarker candidates This talk will introduce the use of different mass spectrometry approaches through examples related to food quality and animal welfare, including studies of gut health in pigs, host pathogen interactions...

  20. Thermal ionisation mass spectrometry: recent developments and future prospects

    International Nuclear Information System (INIS)

    Aggarwal, S.K.

    1996-01-01

    This paper presents the current state of art of thermal ionization mass spectrometry (TIMS) instrumentation and highlights some of the recent applications of TIMS in geological, biological and nuclear sciences with special emphasis on some of the recent work undertaken in the area of nuclear science and technology. A few examples from the published literature are also discussed here

  1. Yeast expression proteomics by high-resolution mass spectrometry

    DEFF Research Database (Denmark)

    Walther, Tobias C; Olsen, Jesper Velgaard; Mann, Matthias

    2010-01-01

    -translational controls contribute majorly to regulation of protein abundance, for example in heat shock stress response. The development of new sample preparation methods, high-resolution mass spectrometry and novel bioinfomatic tools close this gap and allow the global quantitation of the yeast proteome under different...

  2. Minicomputer system for radiochemical analysis by coincidence spectrometry

    International Nuclear Information System (INIS)

    Brauer, F.P.; Fager, J.E.

    1979-01-01

    Minicomputer-based coincidence analysis methods have been developed for use in performing radiochemical analysis by high-resolution x- and gamma-ray coincidence spectrometry. This paper describes the data-acquisition and analysis methods develolped for qualitative and quantitative analyses of coincidence spectrometric data. Data-acquisition capabilities include both direct multiparameter pulse-height analysis and buffered list-mode acquisition

  3. High-Performance Liquid Chromatography-Mass Spectrometry.

    Science.gov (United States)

    Vestal, Marvin L.

    1984-01-01

    Reviews techniques for online coupling of high-performance liquid chromatography with mass spectrometry, emphasizing those suitable for application to nonvolatile samples. Also summarizes the present status, strengths, and weaknesses of various techniques and discusses potential applications of recently developed techniques for combined liquid…

  4. Determination of 226Ra by alpha spectrometry of liquid scintillation

    International Nuclear Information System (INIS)

    Nobrega, A.W.; Sachett, I.A.; Hespanhol, E.C.B.

    1987-01-01

    The determination of 226 Ra in environmental samples using alpha spectrometry in liquid scintilation is studied. The Radon 1-2 emanation method and 226 Ra separation process of other radionuclides alpha emissors are analyzed. The use of 226 Ra coprecipitation with barium sulphate is evaluated. (M.J.C.) [pt

  5. Is it safe to use Poisson statistics in nuclear spectrometry?

    International Nuclear Information System (INIS)

    Pomme, S.; Robouch, P.; Arana, G.; Eguskiza, M.; Maguregui, M.I.

    2000-01-01

    The boundary conditions in which Poisson statistics can be applied in nuclear spectrometry are investigated. Improved formulas for the uncertainty of nuclear counting with deadtime and pulse pileup are presented. A comparison is made between the expected statistical uncertainty for loss-free counting, fixed live-time and fixed real-time measurements. (author)

  6. Concentration of Radon Progeny in Air by Alpha Spectrometry Measurement

    International Nuclear Information System (INIS)

    Acena, M. L.; Crespo, M. T.

    1989-01-01

    The concentration of radon progeny in air has been determined by alpha spectrometry measurement of 214 Po and 318 Po. A known volume of air was passed through a filter, then the alpha activity was directly measured on this filter. (Author) 15 refs

  7. Mass Spectrometry Imaging for the Classification of Tumor Tissue

    NARCIS (Netherlands)

    Mascini, N.E.

    2016-01-01

    Mass spectrometry imaging (MSI) can detect and identify many different molecules without the need for labeling. In addition, it can provide their spatial distributions as ‘molecular maps’. These features make MSI well suited for studying the molecular makeup of tumor tissue. Currently, there is an

  8. Applications of accelerator mass spectrometry: advances and innovation

    International Nuclear Information System (INIS)

    Fifield, L.K.

    2004-01-01

    Emerging trends in the applications of accelerator mass spectrometry (AMS) are identified and illustrated with specific examples. Areas of application covered include rapid landscape evolution, calibration of the radiocarbon time scale, compound-specific radiocarbon studies, tracing of nuclear discharges, and searches for extraterrestrial isotopes

  9. Biomedical mass spectrometry in today's and tomorrow's clinical microbiology laboratories

    NARCIS (Netherlands)

    A.F. van Belkum (Alex); M. Welker (Martin); M. Erhard (Marcel); S. Chatellier (Sonia)

    2012-01-01

    textabstractClinical microbiology is a conservative laboratory exercise where base technologies introduced in the 19th century remained essentially unaltered. High-tech mass spectrometry (MS) has changed that. Within a few years following its adaptation to microbiological diagnostics, MS has been

  10. Mass spectrometry imaging, an emerging technology in neuropsychopharmacology.

    Science.gov (United States)

    Shariatgorji, Mohammadreza; Svenningsson, Per; Andrén, Per E

    2014-01-01

    Mass spectrometry imaging is a powerful tool for directly determining the distribution of proteins, peptides, lipids, neurotransmitters, metabolites and drugs in neural tissue sections in situ. Molecule-specific imaging can be achieved using various ionization techniques that are suited to different applications but which all yield data with high mass accuracies and spatial resolutions. The ability to simultaneously obtain images showing the distributions of chemical species ranging from metal ions to macromolecules makes it possible to explore the chemical organization of a sample and to correlate the results obtained with specific anatomical features. The imaging of biomolecules has provided new insights into multiple neurological diseases, including Parkinson's and Alzheimer's disease. Mass spectrometry imaging can also be used in conjunction with other imaging techniques in order to identify correlations between changes in the distribution of important chemical species and other changes in the properties of the tissue. Here we review the applications of mass spectrometry imaging in neuroscience research and discuss its potential. The results presented demonstrate that mass spectrometry imaging is a useful experimental method with diverse applications in neuroscience.

  11. X-ray fluorescence spectrometry - an introduction course

    International Nuclear Information System (INIS)

    Salvador, V.L.R.

    1989-01-01

    The theoretical and experimental principles of the X-ray fluorescence spectrometry, is presented the text is a synthesis of the most important literature in this area. The authors included are: E.P. Bertin, R. Jenkins, J.L. Devries, R. Muller, R. Tertian, F. Claisse e K.L. Willians. (author)

  12. Portable gamma-ray spectrometers and spectrometry systems

    International Nuclear Information System (INIS)

    Shebell, P.

    1999-01-01

    The current state-of-the-art in portable gamma-ray spectrometers and portable spectrometry systems is discussed. A comparison of detector performance and features of commercially available systems are summarised. Finally, several applications of portable systems are described. (author)

  13. Use of the helium-3 proportional counter for neutron spectrometry

    International Nuclear Information System (INIS)

    Vialettes, H.; Le Thanh, P.

    1967-01-01

    Up to now, two methods have been mainly used for neutron spectrometry near nuclear installations: - photographic emulsion spectrometry - the so-called, 'multisphere' technique spectrometry. The first method, which is fairly difficult to apply, has a threshold energy of about 500 keV; this is a big disadvantage for an apparatus which has to be used for spectrometry around nuclear installations where the neutron radiation is very much degraded energetically. The second method does not suffer from this disadvantage but the results which it yields are only approximate. In order to extend the energy range of the neutron spectra studied with sufficient accuracy the use of a helium-3 proportional counter has been considered. This report presents the principles of operation of the helium-3 spectrometer, and the calculation methods which make it possible to take into account the two main effects tending to deform the spectra obtained: - energy absorption by the walls of the counter, - energy loss of the incident neutrons due to elastic collisions with helium-3 nuclei. As an example of the application, the shape of the neutron spectrum emitted by a polonium-lithium source is given; the results obtained are in excellent agreement with theoretical predictions. (authors) [fr

  14. Capillary filling of miniaturized sources for electrospray mass spectrometry

    International Nuclear Information System (INIS)

    Arscott, Steve; Gaudet, Matthieu; Brinkmann, Martin; Ashcroft, Alison E; Blossey, Ralf

    2006-01-01

    Capillary slot-based emitter tips are a novel tool for use in electrospray ionization-mass spectrometry of large biomolecules. We have performed a combined theoretical and experimental study of capillary filling in micron-sized slots with the aim of developing a rational design procedure for miniaturized electrospray sources, ultimately enabling the integration of ESI into laboratory-on-a-chip devices

  15. Mass spectrometry. Environment, biology, oenology, medicine, geology, chemistry, archaeology, mechanisms

    International Nuclear Information System (INIS)

    1999-01-01

    This document provides the papers (communications and posters) presented at the 16. French days of mass spectrometry, held September 6-9, 1999 in Nancy, France. 5 papers are interesting for the INIS database and are analyzed separately. (O.M.)

  16. Time-of-flight Fourier spectrometry of UCN

    International Nuclear Information System (INIS)

    Kulin, G.V.; Frank, A.I.; Goryunov, S.V.; Kustov, D.V.; Geltenbort, P.; Jentshel, M.; Strepetov, A.N.; Bushuev, V.A.

    2014-01-01

    The results of preliminary experiments on TOF Fourier UCN spectrometry are presented. The description of the new Fourier spectrometer that may be used for the measurement of the UCN spectra arising from diffraction by a moving grating is given. The results of preliminary experiments and Monte Carlo calculations give reason to hope for the success of the planned experiment.

  17. Automatic Compound Annotation from Mass Spectrometry Data Using MAGMa.

    NARCIS (Netherlands)

    Ridder, L.O.; Hooft, van der J.J.J.; Verhoeven, S.

    2014-01-01

    The MAGMa software for automatic annotation of mass spectrometry based fragmentation data was applied to 16 MS/MS datasets of the CASMI 2013 contest. Eight solutions were submitted in category 1 (molecular formula assignments) and twelve in category 2 (molecular structure assignment). The MS/MS

  18. Fast atom bombardment mass spectrometry of condensed tannin sulfonate derivatives

    Science.gov (United States)

    J.J. Karchesy; L.Y. Foo; Richard W. Hemingway; E. Barofsky; D.F. Barofsky

    1989-01-01

    Condensed tannin sulfonate derivatives were studied by fast atom bombardment mass spectrometry (FAB-MS) to assess the feasibility of using this technique for determining molecular weight and structural information about these compounds. Both positive- and negative-ion spectra provided useful data with regard to molecular weight, cation species present, and presence of...

  19. Molecular mass spectrometry imaging in biomedical and life science research

    Czech Academy of Sciences Publication Activity Database

    Pól, Jaroslav; Strohalm, Martin; Havlíček, Vladimír; Volný, Michael

    2010-01-01

    Roč. 134, č. 5 (2010), s. 423-443 ISSN 0948-6143 R&D Projects: GA MŠk LC545; GA ČR GPP206/10/P018 Institutional research plan: CEZ:AV0Z50200510 Keywords : Mass spectrometry * Chemical imaging * Molecular imaging Subject RIV: EE - Microbiology, Virology Impact factor: 4.727, year: 2010

  20. Determination of uranium-235 by differential gamma spectrometry

    International Nuclear Information System (INIS)

    Suner, A.A.; La Gamma de Batistoni, A.M.G.; Botbol, J.

    1974-12-01

    A method for the determination of U-235 contained in solutions of uranium, by gamma spectrometry with Ge(Li) detector is described. Ra-226 is coprecipitated in BaSO 4 . The activity at 186 keV is measured, substracted by the corresponding of a standard. The detection limit is 1% of increment of U-235 over the standard. (author)