WorldWideScience

Sample records for candu operating experience

  1. CANDU operating experience

    International Nuclear Information System (INIS)

    McConnell, L.G.; Woodhead, L.W.; Fanjoy, G.R.

    1982-03-01

    The CANDU Pressurized Heavy Water (CANDU-PHW) type of nuclear electric generating station has been developed jointly by Atomic Energy of Canada Limited and Ontario Hydro. This paper highlights Ontario Hydro's operating experience using the CANDU-PHW system, with a focus on the operating performance and costs, reliability of system components and nuclear safety considerations both to the workers and the public

  2. Ontario Hydro CANDU operating experience

    International Nuclear Information System (INIS)

    Bartholomew, R.W.; Woodhead, L.W.; Horton, E.P.; Nichols, M.J.; Daly, I.N.

    1987-01-01

    The CANDU Pressurized Heavy Water (CANDU-PHW) type of nuclear-electric generating station has been developed jointly by Atomic Energy of Canada Limited and Ontario Hydro. This report highlights Ontario Hydro's operating experience using the CANDU-PHW system, with a focus on worker and public safety, operating performance and costs, and reliability of system components

  3. Ontario Hydro CANDU operating experience

    International Nuclear Information System (INIS)

    Jackson, H.A.; Woodhead, L.W.; Fanjoy, G.R.

    1984-03-01

    The CANDU Pressurized Heavy Water (CANDU-PHW) type of nuclear-electric generating station has been developed jointly by Atomic Energy of Canada Limited and Ontario Hydro. This report highlights Ontario Hydro's operating experience using the CANDU-PHW system, with a focus on the operating performance and costs, reliability of system components and nuclear safety considerations for the workers and the public

  4. CANDU operating experience

    International Nuclear Information System (INIS)

    McConnell, L.G.; Woodhead, L.W.; Fanjoy, G.R.; Thurygill, E.W.

    1980-05-01

    The CANDU-PHW program is based upon 38 years of heavy water reactor experience with 35 years of operating experience. Canada has had 72 reactor years of nuclear-electric operations experience with 10 nuclear units in 4 generating stations during a period of 18 years. All objectives have been met with outstanding performance: worker safety, public safety, environmental emissions, reliable electricity production, and low electricity cost. The achievement has been realized through total teamwork involving all scientific disciplines and all project functions (research, design, manufacturing, construction, and operation). (auth)

  5. Applying operating experience to design the CANDU 3 process

    International Nuclear Information System (INIS)

    Harris, D.S.; Hinchley, E.M.; Pauksens, J.; Snell, V.; Yu, S.K.W.

    1991-01-01

    The CANDU 3 is an advanced, smaller (450 MWe), standardized version of the CANDU now being designed for service later in the decade and beyond. The design of this evolutionary nuclear power plant has been carefully planned and organized to gain maximum benefits from new technologies and from world experience to date in designing, building, commissioning and operating nuclear power stations. The good performance record of existing CANDU reactors makes consideration of operating experience from these plants a particularly vital component of the design process. Since the completion of the first four CANDU 6 stations in the early 1980s, and with the continuing evolution of the multi-unit CANDU station designs since then, AECL CANDU has devised several processes to ensure that such feedback is made available to designers. An important step was made in 1986 when a task force was set up to review and process ideas arising from the commissioning and early operation of the CANDU 6 reactors which were, by that time, operating successfully in Argentina and Korea, as well as the Canadian provinces of Quebec and New Brunswick. The task force issued a comprehensive report which, although aimed at the design of an improved CANDU 6 station, was made available to the CANDU 3 team. By that time also, the Institute of Power Operations (INPO) in the U.S., of which AECL is a Supplier Participant member, was starting to publish Good Practices and Guidelines related to the review and the use of operating experiences. In addition, details of significant events were being made available via the INPO SEE-IN (Significant Event Evaluation and Information Network) Program, and subsequently the CANNET network of the CANDU Owners' Group (COG). Systematic review was thus possible by designers of operations reports, significant event reports, and related documents in a continuing program of design improvement. Another method of incorporating operations feedback is to involve experienced utility

  6. Applying operating experience to design the CANDU 3 process

    Energy Technology Data Exchange (ETDEWEB)

    Harris, D S; Hinchley, E M; Pauksens, J; Snell, V; Yu, S K.W. [AECL-CANDU, Ontario (Canada)

    1991-04-01

    The CANDU 3 is an advanced, smaller (450 MWe), standardized version of the CANDU now being designed for service later in the decade and beyond. The design of this evolutionary nuclear power plant has been carefully planned and organized to gain maximum benefits from new technologies and from world experience to date in designing, building, commissioning and operating nuclear power stations. The good performance record of existing CANDU reactors makes consideration of operating experience from these plants a particularly vital component of the design process. Since the completion of the first four CANDU 6 stations in the early 1980s, and with the continuing evolution of the multi-unit CANDU station designs since then, AECL CANDU has devised several processes to ensure that such feedback is made available to designers. An important step was made in 1986 when a task force was set up to review and process ideas arising from the commissioning and early operation of the CANDU 6 reactors which were, by that time, operating successfully in Argentina and Korea, as well as the Canadian provinces of Quebec and New Brunswick. The task force issued a comprehensive report which, although aimed at the design of an improved CANDU 6 station, was made available to the CANDU 3 team. By that time also, the Institute of Power Operations (INPO) in the U.S., of which AECL is a Supplier Participant member, was starting to publish Good Practices and Guidelines related to the review and the use of operating experiences. In addition, details of significant events were being made available via the INPO SEE-IN (Significant Event Evaluation and Information Network) Program, and subsequently the CANNET network of the CANDU Owners' Group (COG). Systematic review was thus possible by designers of operations reports, significant event reports, and related documents in a continuing program of design improvement. Another method of incorporating operations feedback is to involve experienced utility

  7. Canadian CANDU fuel development program and recent fuel operating experience

    International Nuclear Information System (INIS)

    Lau, J.H.K.; Inch, W.W.R.; Cox, D.S.; Steed, R.G.; Kohn, E.; Macici, N.N.

    1999-01-01

    This paper reviews the performance of the CANDU fuel in the Canadian CANDU reactors in 1997 and 1998. The operating experience demonstrates that the CANDU fuel has performed very well. Over the 2-year period, the fuel-bundle defect rate for all bundles irradiated in the Canadian CANDU reactors has remained very low, at between 0.006% to 0.016%. On a fuel element basis, this represents an element defect rate of less than about 0.0005%. One of the reasons for the good fuel performance is the support provided by the Canadian fuel research and development programs. These programs address operational issues and provide evolutionary improvements to the fuel products. The programs consist of the Fuel Technology Program, funded by the CANDU Owners Group, and the Advanced Fuel and Fuel Cycles Technology Program, funded by Atomic Energy of Canada Ltd. These 2 programs, which have been in place for many years, complement each other by sharing expert resources and experimental facilities. This paper describes the programs in 1999/2000, to provide an overview of the scope of the programs and the issues that these programs address. (author)

  8. Supporting CANDU operators-CANDU owners group

    International Nuclear Information System (INIS)

    Collingwood, B.R.

    1997-01-01

    The CANDU Owners Group (COG) was formed in 1984 by the Canadian CANDU owning utilities and Atomic Energy of Canada limited (AECL). Participation was subsequently extended to all CANDU owners world-wide. The mandate of the COG organization is to provide a framework for co-operation, mutual assistance and exchange of information for the successful support, development, operation, maintenance and economics of CANDU nuclear electric generating stations. To meet these objectives COG established co-operative programs in two areas: 1. Station Support. 2. Research and Development. In addition, joint projects are administered by COG on a case by case basis where CANDU owners can benefit from sharing of costs

  9. The Canadian CANDU fuel development program and recent fuel operating experience

    International Nuclear Information System (INIS)

    Lau, J.H.K.; Inch, W.W.R.; Cox, D.S.; Steed, R.G.; Kohn, E.; Macici, N.N.

    1999-01-01

    This paper reviews the performance of the CANDU fuel in the Canadian CANDU reactors in 1997 and 1998. The operating experience demonstrates that the CANDU fuel has performed very well. Over the two-year period, the fuel-bundle defect rate for all bundles irradiated in the Canadian CANDU reactors has remained very low, at between 0.006% to 0.016%. On a fuel element basis, this represents an element defect rate of less than about 0.0005%. One of the reasons for the good fuel performance is the support provided by the Canadian fuel research and development programs. These programs address operational issues and provide evolutionary improvements to the fuel products. The programs consist of the Fuel Technology Program, funded by the CANDU Owners Group, and the Advanced Fuel and Fuel Cycles Technology Program, funded by Atomic Energy of Canada Ltd. These two programs, which have been in place for many years, complement each other by sharing expert resources and experimental facilities. This paper describes the programs in 1999/2000, to provide an overview of the scope of the programs and the issues that these programs address. (author)

  10. Learning from experience: feedback to CANDU design

    International Nuclear Information System (INIS)

    Allen, P.J.; Hopwood, J.M.; Rousseau, G.P.

    1998-01-01

    AECL's main product line is based on two single unit CANDU nuclear power plant designs; CANDU 6 and CANDU 9, each of which is based on successfully operating CANDU plants. AECL's CANDU development program is based upon evolutionary improvement. The evolutionary design approach ensures the maximum degree of operational provenness. It also allows successful features of today's plants to be retained while incorporating improvements as they develop to the appropriate level of design maturity. A key component of this evolutionary development is a formal process of gathering and responding to feedback from: NPP operation, construction and commissioning; regulatory input; equipment supplier input; R and D results; market input. The progresses for gathering and implementing the experience feedback and a number of recent examples of design improvements from this feedback process are described in the paper. (author)

  11. Operating Experience of MACSTOR Modules at CANDU 6 Stations

    International Nuclear Information System (INIS)

    Beaudoin, Robert R.

    2005-01-01

    Over the last three decades, Atomic Energy of Canada Limited (AECL) has contributed to the technology development and implementation of dry spent fuel management facilities in Canada, Korea and Romania During that period, AECL has developed a number of concrete canister models and the MACSTOR200 module, a medium size air-cooled vault with a 228 MgU (Mega grams of Uranium) capacity. AECL's dry storage technologies were used for the construction of eight large-scale above ground dry storage facilities for CANDU spent fuel. As of 2005, those facilities have an installed capacity in excess of 5,000 MgU. Since 1995, the two newest dry storage installations built for CANDU 6 reactors at Gentilly 2 (Canada) and Cernavoda (Romania) used the MACSTOR 200 module. Seven such modules have been built at Gentilly 2 during the 1995 to 2004 period and one at Cernavoda in 2003. The construction and operating experience of those modules is reviewed in this paper. The MACSTOR 200 modules were initially designed for a 50-year service life, with recent units at Gentilly 2 licensed for a 100-year service life in a rural (non-maritime) climate. During the 1995-2005 period, six of the eight modules were loaded with fuel. Their operation has brought a significant amount of experience on loading operations, performance of fuel handling equipment, radiation shielding, heat transfer, monitoring of the two confinement boundaries and radiation dose to personnel. Heat dissipation performance of the MACSTOR 200 was initially licensed using values derived from full scale tests made at AECL's Whiteshell Research Laboratories, that were backed-up by temperature measurements made on the first two modules. Results and computer models developed for the MACSTOR 200 module are described. Korea Hydro and Nuclear Power (KHNP) and its subsidiary Nuclear Environment Technology Institute (NETEC), in collaboration with Hyundai Engineering Company Ltd. (HEC) and AECL, are developing a new dry storage module to

  12. Operating experiences with Neutron Overpower Trip Systems in Ontario Hydro's CANDU nuclear plants

    International Nuclear Information System (INIS)

    Hnik, J.; Kozak, J.

    1991-01-01

    Operating experiences with Neutron Over Power Trip (NOP) Systems in different Ontario Hydro CANDU nuclear power plants are discussed. Lessons learned from the system operation and their impact on design improvements are presented. Retrofitting of additional tools, such as Shutdown System Monitoring computers, to improve operator interaction with the system is described. Experiences with the reliability of some of the NOP system components is also discussed. Options for future enhancements of system performance and operability are identified. (author)

  13. CANDU 9 Design improvements based on experience feedback

    International Nuclear Information System (INIS)

    Yu, S. K. W.; Bonechi, M.; Snell, V. G.

    2000-01-01

    An evolutionary approach utilizing advance technologies has been implenented for the enhancement introduced in the CANDU 9 Nuclear Power Plant (NPP) design. The design of these systems and associated equipment has also benfited from experience feedback from operating CANDU stations and from including advanced products from CANDU engineering and research programs. This paper highlights the design features that contribute to the safety improvements of the CANDU 9 design, summarizes the analysis results which demonstrate the improved performance and also emphasizes design features which reduce operation and maintenance (Q and M) costs. The safety design features highlighted include the increased use of passive devices and heat sinks to achieve extensive system simplification; this also improves reliability and reduces maintenance workloads. System features that contribute to improved operability are also described. The CANDU 9 Control Center provides plant staff with enhanced operating, maintenance and diagnostics features which significantly improve operability, testing and maintainability due to the integration of human factors engineering with a systematic design process. (author)

  14. The licensing process of the design modifications of Cernavoda 2 NPP resulting from the operating experience of CANDU plants

    International Nuclear Information System (INIS)

    Goicea, L.

    2005-01-01

    The CANDU 6 plant now under construction in Cernavoda include over two hundred significant improvements made in order to comply with current codes and standards and licensing requirements relative to the operating CANDU 6 in Romania. These evolutionary improvements are incorporated in CANDU 6 design taking advance of CANDU operating experience, of the designer company research and development and technical advances worldwide in order to further enhance safety, reliability and economics. This paper gives a general idea of the evaluation of the modifications of the Cernavoda 2 nuclear power plant against the design of Cernavoda 1 and states the safety principles and requirements which are the basis for this evaluation. (author)

  15. Role of operator response guidelines in CANDU 9 design program

    International Nuclear Information System (INIS)

    Jaitly, R.K.

    2000-01-01

    The CANDU 9 is a large version of the CANDU Pressurized Heavy Water Reactor (PHWR) system developed in Canada. With an electrical output of approximately 935 MWe, the CANDU 9 complements the established mid-size CANDU 6 (700 MWe) and makes use of proven technology updated with state of the art features resulting from ongoing development. The CANDU 9 builds on the reactor and process system designs of the operating Darlington and Bruce B plants, and incorporates a modified CANDU 6 station layout, as well as improved construction methods and operational features. A high level of standardization has always been a feature of CANDU reactors. This theme is emphasized in the CANDU 9; all key components (reactor core, steam generators, coolant pumps, pressure tubes, etc.) are of the same design as those proven in service in the operating CANDU power stations. Including Probabilistic Safety Assessment (PSA) as part of the CANDU 9 design process from the outset of the program was seen as key to ensuring completeness of safety related requirements. The PSA work provided an in-depth understanding of the plant response to various postulated accidents. As well, the time frame for recovery and the related operator actions were identified. This information together with AECL's experience in supporting the development of Emergency Operating Procedures (EOPs) for the operating CANDU reactors are the basis for preparation of CANDU 9 Operator Response Guidelines (ORGs). Technical content, format and human factors considerations adopted for the ORGs are such that these can be readily converted to EOPs. The scope of ORGs includes generic as well as event specific ORGs. This dual approach is required to provide defense-in-depth. This paper describes the process used to prepare ORGs for the CANDU 9 reactor and discusses important benefits gained from the application of ORGs as input to the control center design and future preparation of the EOPs. (author)

  16. Advanced CANDU reactor design for operability

    International Nuclear Information System (INIS)

    Hopwood, J.M.; Lalonde, R.; Soulard, M.

    2003-01-01

    This paper outlines design features and engineering processes in the ACR TM development program which contribute to excellence in performance and low operating cost. AECL recognizes that future plant owners will place a high priority in these operational characteristics. A successful next generation plant will have a best-in-class capability, both in its design characteristics, in the engineering philosophy and program adopted during the product development, and in the vendor's approach to operating station support. The ACR program addresses each of these drivers. Operability considerations are built-in to the design at an overall, plant wide level. For example, based on the strong CANDU 6 operating record, targets for standard outage duration, time between outages and component durability are set, while the design engineering is managed to achieve these targets. The ultimate maintenance target for the ACR, once initial operating experience has been gained, is to operate with a 21-day standard maintenance outage at an interval of once every three years. At the detailed design level, close attention is paid to space allocation, to enable good maintenance access. Selection of components also places emphasis on maintainability based on the extensive and current experience with CANDU projects. (author)

  17. Candu 600 fuelling machine testing, the romanian experience

    International Nuclear Information System (INIS)

    Valeca, S.; Doca, C.; Iorga, C.

    2013-01-01

    The Candu 600 Fuelling Machine is a complex mechanism which must run in safety conditions and with high reliability in the Candu Reactor. The testing and commissioning process of this nuclear equipment meets the high standards of NPPs requirements using special technological facilities, modern measurement instruments as well the appropriate IT resources for data acquisition and processing. The paper presents the experience of the Institute for Nuclear Research Pitesti, Romania, in testing Candu 600 Fuelling Machines, inclusive the implied facilities, and in development of four simulators: two dedicated for the training of the Candu 600 Fuelling Machine Operators, and another two to simulate some process signals and actions. (authors)

  18. CANDU 9 operator plant display system

    International Nuclear Information System (INIS)

    Trueman, R.; Webster, A.; MacBeth, M.J.

    1997-01-01

    To meet evolving client and regulatory needs, AECL has adopted an evolutionary approach to the design of the CANDU 9 control centre. That is, the design incorporates feedback from existing stations, reflects the growing diversity in the roles and responsibilities of the operating staff, and reduces costs associated with plant capital and operations, maintenance and administration (OM and A), through the appropriate introduction of new technologies. Underlying this approach is a refined engineering design process that cost-effectively integrates operational feedback and human factors engineering to define the operating staff information and information presentation requirements. Based on this approach, the CANDU 9 control centre will provide utility operating staff with the means to achieve improved operations and reduced OM and A costs. One of the design features that will contribute to the improved operational capabilities of the control centre is a new Plant Display System (PDS) that is separate from the digital control system. The PDS will be used to implement non-safety panel, and console video display systems within the CANDU 9 main control room (MCR). This paper presents a detailed description of the CANDU 9 Plant Display System and features that provide increased operational capabilities. (author)

  19. CANDU reactor experience: fuel performance

    International Nuclear Information System (INIS)

    Truant, P.T.; Hastings, I.J.

    1985-07-01

    Ontario Hydro has more than 126 reactor-years experience in operating CANDU reactors. Fuel performance has been excellent with 47 000 channel fuelling operations successfully completed and 99.9 percent of the more than 380 000 bundles irradiated operating as designed. Fuel performance limits and fuel defects have had a negligible effect on station safety, reliability, the environment and cost. The actual incapability charged to fuel is less than 0.1 percent over the stations' lifetimes, and more recently has been zero

  20. The CANDU experience in Romania

    International Nuclear Information System (INIS)

    Smith, A.I.

    1984-01-01

    The CANDU program in Romania is now well established. The Cernavoda Nuclear Station presently under construction will consist of 5-CANDU 600 MWE Units and another similar size station is planned to be in operation in the next decade. Progress on the multi-unit station at Cernavoda was stalled for 18 months in 1982/83 as the Canadian Export Development Corporation had suspended their loan disbursements while the Romanian National debt was being rescheduled. Since resumption of the financing in August 1983 contracts worth almost 200M dollars have been placed with Canadian Companies for the supply of major equipment for the first two units. The Canadian design is that which was used in the latest 600 MWE CANDU station at Wolsong, Korea. The vast construction site is now well developed with the cooling water systems/channels and service buildings at an advanced stage of completion. The perimeter walls of the first two reactor buildings are already complete and slip-forming for the 3rd Unit is imminent. Many Romanian organizations are involved in the infrastructure which has been established to handle the design, manufacture, construction and operation of the CANDU stations. The Romanian manufacturing industry has made extensive preparations for the supply of CANDU equipment and components, and although a major portion of the first two units will come from Canada their intentions are to become largely self-supporting for the ensuing CANDU program. Quality assurance programs have been prepared already for many of the facilities

  1. Leak before break experience in CANDU reactors

    International Nuclear Information System (INIS)

    Price, E.G.; Moan, G.D.; Coleman, C.E.

    1988-04-01

    The paper describes how the requirements for Leak-Before-Break are met in CANDU reactors. The requirements are based on operational and laboratory experience. After the onset of leakage in a fuel channel from a delayed hydride crack, time is available to the operator to take action before the crack grows to an unstable length. The time available is calculated using different models which use crack growth data from small specimen tests. When the results from crack growth behaviour experiments, carried out on components removed from reactor are used in the model, the time available for operator response is about 100 hours

  2. Experience teaching CD-ROM-based course on CANDU nuclear-power-plant systems and operation

    International Nuclear Information System (INIS)

    Rouben, Benjamin

    2008-01-01

    This paper presents personal experience garnered from teaching a CD-ROM-based course on CANDU Power-Plant Systems and Operation. This course was originally developed by Prof. G.T. Bereznai as research in distance-learning techniques when he was directing the Thai-Canadian Human Resources Development Project at Chulalongkorn University in Bangkok. The course has been offered in a number of universities, including McMaster University and the University of Ontario Institute of Technology. All the course material, including lectures, assignments, and a simulator, is provided on a CD-ROM. Lectures include a spoken soundtrack covering the material. The class often includes both undergraduate and graduate students. I found that most students appreciate having the material on electronic format, which they can view and review at will and on their own time. Students find this course quite intensive - it covers all major systems in the CANDU reactor and power plant in detail. A very important component of the course is the simulator, which teaches students how systems operate in normal operation, in power manoeuvres, and during process-system malfunctions. Effort in absorbing the material and performing assignments can often exceed 10 hours per week. Some of the simulator assignments involve tricky manoeuvres, requiring several tries to achieve the expected result. Some assignments may take several hours, especially if the manoeuvres requiring repetition take 30 minutes or more in real time. I found that some instruction in the basic theory of reactor physics and systems is appreciated by students. A few possible enhancements to the simulator model were identified. Graduate students taking the course are required to do an additional project; I assigned an investigation of the effects of xenon-concentration changes during 1 week of load cycling. In summary, this course provides to students the opportunity to learn a great deal about the workings of CANDU-plant systems. (author)

  3. Improved operability of the CANDU 9 control centre

    International Nuclear Information System (INIS)

    Macbeth, M. J.; Webster, A.

    1996-01-01

    The next generation CANDU nuclear power plant being designed by AECL is the 900 MWe class CANDU 9 station. It is based upon the Darlington CANDU station design which is among the world leaders in capacity factor with low Operation, Maintenance and Administration (OM and A) costs. This Control Centre design includes the proven functionality of existing CANDU control centres (including the Wolsong 2,3, and 4 control centre improvements, such as the Emergency Core Cooling panels), the characteristics identified by systematic design with human factors analysis of operations requirements and the advanced features needed to improve station operability which is made possible by the application of new technology. The CANDU 9 Control Centre provides plant staff with an improved operability capability due to the combination of proveness, systematic design with human factors engineering and enhanced operating features. Significant features which contribute to this improved operability include: · Standard NSP, BOP and F/H panels with controls and indicators integrated by a standard display/presentation philosophy. · Common plant parameter signal database for extensive monitoring, checking, display and annunciation. · Powerful annunciation system allowing alarm filtering, prioritizing and interrogation to enhance staff recognition of events, plant state and required corrective procedural actions. · The use of an overview display to present immediate and uncomplicated plant status information to facilitate operator awareness of unit status in a highly readable and recognizable format. · Extensive cross checking of similar process parameters amongst themselves, with the counterpart safety system parameters and as well as with 'signature' values obtained from known steady state conditions. · Powerful calculation capabilities, using the plant wide database, providing immediate recognizable and readable and readable output data on plant state information and plant state change

  4. Operating performance and reliability of CANDU PHWR fuel channels in Canada

    International Nuclear Information System (INIS)

    Strachan, B.; Brown, D.R.

    1983-03-01

    CANDU nuclear plants use many small-diameter high-pressure fuel channels. Good operating performance from the CANDU fuel channels has made a major contribution to the world-leading operating record of the CANDU nuclear power plants. As of 1982 December 31, there were 7,480 fuel channels installed in 18 CANDU reactors over 500 MW(e) in size. Eight of these reactors have been declared in-service and have accumulated 24,000 fuel channel-years of operation. The only significant operating problems with fuel channels have been the occurrence of leaking cracks in 70 fuel channels and a larger amount of axial creep on the early reactors than was originally provided for in the design. Both of these problems have been corrected on all CANDU reactors built since the Bruce GS 'A' station and the newer reactors should exhibit even better performance

  5. ITER SAFETY TASK NID-10A:CANDU occupational exposure experience: ORE for ITER fuel cycle and cooling systems

    International Nuclear Information System (INIS)

    Lee, D.

    1995-02-01

    This report contains information on TRITIUM Occupational Exposure (Internal Dose) from typical CANDU Nuclear Generating Stations. In addition to dose, airborne tritium levels are provided, as these strongly influence operational exposure. The exposure dose data presented in this report cover a period of five years of operation and maintenance experience from four CANDU Reactors and are considered representative of other CANDU reactors. The data are broken down according to occupational function ( Operators, Maintenance and Support Service etc.). The referenced systems are mainly centered on CANDU Hear Transport System, Moderator System, Tritium Removal Facility and Heavy Water (D20) Upgrading System. These systems contain the bulk part of tritium contamination in the CANDU Reactor. Because of certain similarities between ITER and CANDU systems, this data can be used as the most relevant TRITIUM OCCUPATIONAL DOSE information for ITER COOLING and FUEL CYCLE systems dose assessment purpose, if similar design and operation principles as described in the report are adopted. (author). 16 refs., 8 tabs., 13 figs

  6. Improving CANDU plant operation and maintenance through retrofit information technology systems

    International Nuclear Information System (INIS)

    Lupton, L.R.; Judd, R.A.; MacBeth, M.J.

    1998-01-01

    CANDU plant owners are facing an increasingly competitive environment for the generation of electricity. To meet this challenge, all owners have identified that information technology offers opportunities for significant improvements in CANDU operation, maintenance and administration (OM and A) costs. Targeted information technology application areas include instrumentation and control, engineering, construction, operations and plant information management. These opportunities also pose challenges and issues that must be addressed if the full benefits of the advances in information technology are to be achieved. Key among these are system hardware and software maintenance, and obsolescence protection; AECL has been supporting CANDU stations with the initial development and evaluation of systems to improve plant performance and cost. Key initiatives that have been implemented or are in the process of being implemented in some CANDU plants to achieve operational benefits include: critical safety parameter monitor system; advanced computerized annunciation system; plant historical data system; and plant display system. Each system will be described in terms of its role in enhancing current CANDU plant performance and how they will contribute to future CANDU plant performance

  7. CANDU nuclear reactor technology

    International Nuclear Information System (INIS)

    Kakaria, B. K.

    1994-01-01

    AECL has over 40 years of experience in the nuclear field. Over the past 20 years, this unique Canadian nuclear technology has made a worldwide presence, In addition to 22 CANDU reactors in Canada, there are also two in India, one in Pakistan, one in Argentina, four in Korea and five in Romania. CANDU advancements are based on evolutionary plant improvements. They consist of system performance improvements, design technology improvements and research and development in support of advanced nuclear power. Given the good performance of CANOU plants, it is important that this CANDU operating experience be incorporated into new and repeat designs

  8. The next generation CANDU 6

    International Nuclear Information System (INIS)

    Hopwood, J.M.

    1999-01-01

    AECL's product line of CANDU 6 and CANDU 9 nuclear power plants are adapted to respond to changing market conditions, experience feedback and technological development by a continuous improvement process of design evolution. The CANDU 6 Nuclear Power Plant design is a successful family of nuclear units, with the first four units entering service in 1983, and the most recent entering service this year. A further four CANDU 6 units are under construction. Starting in 1996, a focused forward-looking development program is under way at AECL to incorporate a series of individual improvements and integrate them into the CANDU 6, leading to the evolutionary development of the next-generation enhanced CANDU 6. The CANDU 6 improvements program includes all aspects of an NPP project, including engineering tools improvements, design for improved constructability, scheduling for faster, more streamlined commissioning, and improved operating performance. This enhanced CANDU 6 product will combine the benefits of design provenness (drawing on the more than 70 reactor-years experience of the seven operating CANDU 6 units), with the advantages of an evolutionary next-generation design. Features of the enhanced CANDU 6 design include: Advanced Human Machine Interface - built around the Advanced CANDU Control Centre; Advanced fuel design - using the newly demonstrated CANFLEX fuel bundle; Improved Efficiency based on improved utilization of waste heat; Streamlined System Design - including simplifications to improve performance and safety system reliability; Advanced Engineering Tools, -- featuring linked electronic databases from 3D CADDS, equipment specification and material management; Advanced Construction Techniques - based on open top equipment installation and the use of small skid mounted modules; Options defined for Passive Heat Sink capability and low-enrichment core optimization. (author)

  9. The CANDU 3 containment structure

    International Nuclear Information System (INIS)

    1994-01-01

    The design of the CANDU 3 nuclear power plant is being developed by AECL CANDU's Saskatchewan office. There are 24 CANDU nuclear power units operating in Canada and abroad and eight units are under construction is Romania and South Korea. The design of the CANDU 3 plant has evolved on the basis of the proven CANDU design. The experiences gained during construction, commissioning and operation of the existing CANDU plants are considered in the design. Many technological enhancements have been implemented in the design processes in all areas. The object has been to develop an improved reactor design that is suitable for the current and the future markets worldwide. Throughout the design phase of CANDU 3, emphasis has been placed in reducing the cost and construction schedule of the plant. This has been achieved by implementing design improvements and using new construction techniques. Appropriate changes and improvements to the design to suit new requirements are also adopted. In CANDU plants, the containment structure acts as an ultimate barrier against the leakage of radioactive substances during normal operations and postulated accident conditions. The concept of the structural design of the containment structure has been examined in considerable detail. This has resulted in development of a new conceptual design for the containment structure for CANDU 3. This paper deals with this new design of the containment structure

  10. Advanced operator interface design for CANDU-3 fuel handling system

    Energy Technology Data Exchange (ETDEWEB)

    Arapakota, D [Atomic Energy of Canada Ltd., Saskatoon, SK (Canada)

    1996-12-31

    The Operator Interface for the CANDU 3 Fuel Handling (F/H) System incorporates several improvements over the existing designs. A functionally independent sit-down CRT (cathode-ray tube) based Control Console is provided for the Fuel Handling Operator in the Main Control Room. The Display System makes use of current technology and provides a user friendly operator interface. Regular and emergency control operations can be carried out from this control console. A stand-up control panel is provided as a back-up with limited functionality adequate to put the F/H System in a safe state in case of an unlikely non-availability of the Plant Display System or the F/H Control System`. The system design philosophy, hardware configuration and the advanced display system features are described in this paper The F/H Operator Interface System developed for CANDU 3 can be adapted to CANDU 9 as well as to the existing stations. (author).

  11. Advanced operator interface design for CANDU-3 fuel handling system

    International Nuclear Information System (INIS)

    Arapakota, D.

    1995-01-01

    The Operator Interface for the CANDU 3 Fuel Handling (F/H) System incorporates several improvements over the existing designs. A functionally independent sit-down CRT (cathode-ray tube) based Control Console is provided for the Fuel Handling Operator in the Main Control Room. The Display System makes use of current technology and provides a user friendly operator interface. Regular and emergency control operations can be carried out from this control console. A stand-up control panel is provided as a back-up with limited functionality adequate to put the F/H System in a safe state in case of an unlikely non-availability of the Plant Display System or the F/H Control System'. The system design philosophy, hardware configuration and the advanced display system features are described in this paper The F/H Operator Interface System developed for CANDU 3 can be adapted to CANDU 9 as well as to the existing stations. (author)

  12. Improving CANDU plant operation and maintenance through retrofit information technology systems

    International Nuclear Information System (INIS)

    Lupton, L. R.; Judd, R. A.

    1998-01-01

    CANDU plant owners are facing an increasingly competitive environment for the generation of electricity. To meet this challenge, all owners have identified that information technology offers opportunities for significant improvements in CANDU operation, maintenance and administration (OM and A) costs. Targeted information technology application areas include instrumentation and control, engineering, construction, operations and plant information management. These opportunities also pose challenges and issues that must be addressed if the full benefits of the advances in information technology are to be achieved. Key among these are system hardware and software maintenance, and obsolescence protection. AECL has been supporting CANDU stations with the initial development and evaluation of systems to improve plant performance and cost. Five key initiatives that have been implemented or are in the process of being implemented in some CANDU plants to achieve cooperational benefits include: critical safety parameter monitor system; advanced computerized annunciation system; plant historical data system; plant display system; and digital protection system. Each system will be described in terms of its role in enhancing current CANDU plant performance and how they will contribute to future CANDU plant performance. (author). 8 refs., 3 figs

  13. CANDU safety under severe accidents

    International Nuclear Information System (INIS)

    Snell, V.G.; Howieson, J.Q.; Frescura, G.M.; King, F.; Rogers, J.T.; Tamm, H.

    1988-01-01

    The characteristics of the CANDU reactor relevant to severe accidents are set first by the inherent properties of the design, and second by the Canadian safety/licensing approach. Probabilistic safety assessment studies have been performed on operating CANDU plants, and on the 4 x 880 MW(e) Darlington station now under construction; furthermore a scoping risk assessment has been done for a CANDU 600 plant. They indicate that the summed severe core damage frequency is of the order of 5 x 10 -6 /year. CANDU nuclear plant designers and owner/operators share information and operational experience nationally and internationally through the CANDU Owners' Group (COG). The research program generally emphasizes the unique aspects of the CANDU concept, such as heat removal through the moderator, but it has also contributed significantly to areas generic to most power reactors such as hydrogen combustion, containment failure modes, fission product chemistry, and high temperature fuel behaviour. Abnormal plant operating procedures are aimed at first using event-specific emergency operating procedures, in cases where the event can be diagnosed. If this is not possible, generic procedures are followed to control Critical Safety Parameters and manage the accident. Similarly, the on-site contingency plans include a generic plan covering overall plant response strategy, and a specific plan covering each category of contingency

  14. Experience in operation of heavy water reactors

    International Nuclear Information System (INIS)

    Rotaru, Ion; Bilegan, Iosif; Ghitescu, Petre

    1999-01-01

    The paper presents the main topics of the CANDU owners group (COG) meeting held in Mangalia, Romania on 7-10 September 1998. These meetings are part of the IAEA program for exchange of information related mainly to CANDU reactor operation safety. The first meeting for PHWR reactors took place in Vienna in 1989, followed by those in Argentina (1991), India (1994) and Korea (1996). The topics discussed at the meeting in Romania were: operation experience and recent major events, performances of CANDU reactors and safe operation, nuclear safety and operation procedures of PHWR, programs and strategies of lifetime management of installations and components of NPPs, developments and updates

  15. Evolutionary CANDU 9 plant improvements

    International Nuclear Information System (INIS)

    Yu, S.K.W.

    1999-01-01

    The CANDU 9 is a 935 MW(e) nuclear power plant (NPP) based on the multi-unit Darlington and Bruce B designs with additional enhancements from our ongoing engineering and research programs. Added to the advantages of using proven systems and components, CANDU 9 offers improvement features with enhanced safety, improved operability and maintenance including a control centre with advanced man-machine interface, and improved project delivery in both engineering and construction. The CANDU 9 NPP design incorporated safety enhancements through careful attention to emerging licensing and safety issues. The designers assessed, revised and evolved such systems as the moderator, end shield, containment and emergency core cooling (ECC) systems while providing an integrated final design that is more passive and severe-accident-immune. AECL uses a feedback process to incorporate lessons learned from operating plants, from current projects experiences and from the implementation or construction phase of previous projects. Most of the requirements for design improvements are based on a systematic review of current operating CANDU stations in the areas of design and reliability, operability, and maintainability. The CANDU 9 Control Centre provides plant staff with improved operability and maintainability capabilities due to the combination of systematic design with human factors engineering and enhanced operating and diagnostics features. The use of advanced engineering tools and modem construction methods will reduce project implementation risk on project costs and schedules. (author)

  16. Reactor physics aspects of CANDU reactors

    International Nuclear Information System (INIS)

    Critoph, E.

    1980-01-01

    These four lectures are being given at the Winter Course on Nuclear Physics at Trieste during 1978 February. They constitute part of the third week's lectures in Part II: Reactor Theory and Power Reactors. A physical description of CANDU reactors is given, followed by an overview of CANDU characteristics and some of the design options. Basic lattice physics is discussed in terms of zero energy lattice experiments, irradiation effects and analytical methods. Start-up and commissioning experiments in CANDU reactors are reviewed, and some of the more interesting aspects of operation discussed - fuel management, flux mapping and control of the power distribution. Finally, some of the characteristics of advanced fuel cycles that have been proposed for CANDU reactors are summarized. (author)

  17. LOCA assessment experiments in a full-elevation, CANDU-typical test facility

    International Nuclear Information System (INIS)

    Ingham, P.J.; McGee, G.R.; Krishnan, V.S.

    1990-01-01

    The RD-14 thermal-hydraulics test facility, located at the Whiteshell Nuclear Research Establishment, is a full-elevation model representative of a CANDU primary heat transport system. The facility is scaled to accommodate a single, full-scale (5.0 MW, 21 kg/s), electrically heated channel per pass. The steam generators, pumps, headers, feeders and heated channels are arranged in a typical CANDU figure-of-eight geometry. The loop has an emergency coolant injection system (ECI) that may be operated in several modes, including typical features of the various ECI systems found in CANDU reactors. A series of experiments has been performed in RD-14 to investigate the thermal-hydraulic behaviour during the blowdown and injection phases of a loss-of-coolant accident (LOCA). The tests were designed to cover a full range of break sizes from feeder-sized breaks to guillotine breaks in either an inlet or an outlet header. Breaks resulting in channel flow stagnation were also investigated. This paper reviews the results of some of the LOCA tests carried out in RD-14, and discusses some of the behaviour observed. Plans for future experiments in a multiple-channel RD-14 facility, modified to contain multiple flow channels, are outlined. (orig.)

  18. CANDU fuel - fifteen years of power reactor experience

    International Nuclear Information System (INIS)

    Fanjoy, G.R.; Bain, A.S.

    1977-01-01

    CANDU (Canada Deuterium Uranium) fuel has operated in power reactors since 1962. Analyses of performance statistics, supplemented by examinations of fuel from power reactors and experimental loops have yielded: (a) A thorough understanding of the fundamental behaviour of CANDU fuel. (b) Data showing that the predicted high utilization of uranium has been achieved. Actual fuelling costs in 1976 at the Pickering Generating Station are 1.2 m$/kWh (1976 Canadian dollars) with the simple oncethrough natural-UO 2 fuel cycle. (c) Criteria for operation, which have led to the current very low defect rate of 0.03% of all assemblies and to ''CANLUB'' fuel, which has a graphite interlayer between the fuel and sheath to reduce defects on power increases. (d) Proof that the short length (500 mm), collapsible cladding features of the CANDU bundle are successful and that the fuel can operate at high-power output (current peak outer-element linear power is 58 +- 15% kW/m). Involvement by the utility in all stages of fuel development has resulted in efficient application of this fundamental knowledge to ensure proper fuel specifications, procurement, scheduling into the reactor and feedback to developers, designers and manufacturers. As of mid-1976 over 3 x 10 6 individual elements have been built in a well-estabilished commercially competitive fuel fabrication industry and over 2 x 10 6 elements have been irradiated. Only six defects have been attributed to faulty materials or fabrication, and the use of high-density UO 2 with low-moisture content precluded defects from hydrogen contamination and densification. Development work on UO 2 and other fuel cycles (plutonium and thorium) is continuing, and, because CANDU reactors use on-power fuelling, bundles can be inserted into power reactors for testing. Thus new fuel designs can be quickly adopted to ensure that the CANDU system continues to provide low-cost energy with high reliability

  19. Delivery improvements for CANDU projects

    International Nuclear Information System (INIS)

    Stephen Yu; Ken Hedges

    1998-01-01

    Future CANDU design will continue to meet emerging design and performance requirements as expected by the operating utilities, and will integrate new technologies into both the product features and work processes. Elements of this risk reduction strategy include feedback of lessons learned from operating plants, project experiences from previous projects, and replication of successful systems and equipment. Project implementation risk is minimized by up-front engineering and licensing prior to contract start. Enhanced competitiveness of the CANDU products is ensured by incorporating improvements based on updated technology. This paper summarizes the strategy used to enhance competitiveness of the CANDU products and the measures introduced to minimize risk during project implementation. This strategy provides a balance between innovation and proven designs; and between the desire for safety and operational improvements and the cost to achieve the improvements

  20. Feedback of operation and maintenance experience into evolutionary plant design (HWRs)

    International Nuclear Information System (INIS)

    Hedges, K.R.; Sanatkumar, A.; Kwon, Oh-Cheol

    1999-01-01

    The process of feeding back operation and maintenance information into the CANDU plant design process has been in constant evolution since the beginning of the CANDU program. The commissioning and operation experience from the first commercial reactors at Pickering A and Bruce A was used extensively in the design of the first generation CANDU 6 Plants. These units have been in operation for 15 years, producing electricity at an average lifetime capacity factor of about 85%. In further advancing the CANDU 6 and 9 design, greater emphasis is placed on enhancements that can reduce operational costs and further improve plant performance by reducing the planned outage time. The plant design has been improved to facilitate maintenance scheduling, equipment isolation, maintenance and post maintenance testing. Individual tasks have been analyzed as well as the interaction between tasks during outages to reduce the down time required and simplify the execution of the work. This results in shorter outages, reduced radioactive dose and reduced costs. The Utilities have continued to play an important role in CANDU 6 Evolution. Specifically; the Korea Utility KEPCO has one of the original four CANDU 6 Plants and three of the most modem. Their feedback to the designers has been very helpful. One of the most important feedback processes is through the CANDU Owners Group, which provides information exchange between members. In India eight PHWRs of 220 MWe capacity are in operation. Four reactors, also of 220 MWe capacity are in advanced stages of construction. Site construction work of two units of 500 MWe PHWRs at Tarapur will be taken up shortly. Over the years, during construction and operation of these power stations, a large amount of experience has been accumulated. Operation and maintenance experience is shared with operating stations by intensive participation of design engineers in Station Operation Review meetings, trouble shooting and root cause analysis of problems

  1. Maintenance, rehabilitation, long life-the CANDU potential

    International Nuclear Information System (INIS)

    Torgerson, D.F.; Charlebois, P.; Hopkins, J.

    1998-01-01

    Plant life extension beyond the original design life is becoming an attractive economic consideration in the nuclear industry. Plant Life Management and life extension considerations have been built into the complete life cycle of the CANDU plant. The plant life management studies demonstrate that life extension for operating plants beyond 30 years is economically viable. The new CANDU designs benefit from this experience feedback and as a result, the plant design basis is now 40 years or better with potential for economical life extension. AECL is therefore confident that the new CANDU designs will exceed the performance record of the first generation CANDU 6 units and is committed to providing continued support and services during the operating life of the plant

  2. Canadian fuel development program and recent operational experience

    International Nuclear Information System (INIS)

    Cox, D.S.; Kohn, E.; Lau, J.H.K.; Dicke, G.J.; Macici, N.N.; Sancton, R.W.

    1995-01-01

    This paper provides an overview of the current Canadian CANDU fuel R and D programs and operational experience. The details of operational experience for fuel in Canadian reactors are summarized for the period 1991-1994; excellent fuel performance has been sustained, with steady-state bundle defect rates currently as low as 0.02%. The status of introducing long 37-element bundles, and bundles with rounded bearing pads is reviewed. These minor changes in fuel design have been selectively introduced in response to operational constraints (end-plate cracking and pressure-tube fretting) at Ontario Hydro's Bruce-B and Darlington stations. The R and D programs are generating a more complete understanding of CANDU fuel behaviour, while the CANDU Owners Group (COG) Fuel Technology Program is being re-aligned to a more exclusive focus on the needs of operating stations. Technical highlights and realized benefits from the COG program are summarized. Re-organization of AECL to provide a one-company focus, with an outward looking view to new CANDU markets, has strengthened R and D in advanced fuel cycles. Progress in AECL's key fuel cycle programs is also summarized. (author)

  3. The CANDU 9

    International Nuclear Information System (INIS)

    Hart, R.S.

    1994-01-01

    The CANDU 9 plants are single unit versions of the Bruce B design, incorporating relevant technical advances made in CANDU 6, and the newer Darlington and CANDU 3 designs. This paper describes the CANDU 9 480/SEU, with an electrical output of about 1050 MW. In this designation, 480 refers to the number of fuel channels, and SEU to slightly enriched uranium. Emphasis is placed on evolutionary design, and the use of well proven design features, to ensure regulatory licensability and reliable operation. Safety is enhanced through simplification and improvement of key systems and components. Relatively low energy costs result from reduced specific capital cost, reduced operating and maintenance cost, and reduced radiation exposure to personnel. Standardization is emphasized inasmuch as all key components (steam generators, heat transport pumps, pressure tubes fuelling machines etc.) ar of the same design as those in operating CANDU stations. Advanced CANDU fuel cycles are readily accommodated. 1 ref., 1 tab., 11 figs

  4. Severe core damage experiments and analysis for CANDU applications

    International Nuclear Information System (INIS)

    Mathew, P.M.; White, A.J.; Snell, V.G.; Bonechi, M.

    2003-01-01

    AECL uses the MAAP CANDU code to calculate the progression of a severe core damage accident in a CANDU reactor to support Level 2 Probabilistic Safety Assessment and Severe Accident Management activities. Experimental data are required to ensure that the core damage models used in MAAP CANDU code are adequate. In SMiRT 16, details of single channel experiments were presented to elucidate the mechanisms of core debris formation. This paper presents the progress made in severe core damage experiments since then using single channels in an inert atmosphere and results of the model development work to support the experiments. The core disassembly experiments are conducted with one-fifth scale channels made of Zr-2.5wt%Nb containing twelve simulated fuel bundles in an inert atmosphere. The reference fuel channel geometry consists of a pressure tube/calandria tube composite, with the pressure tube ballooned into circumferential contact with the calandria tube. Experimental results from single channel tests showed the development of time-dependent sag when the reference channel temperature exceeded 850 degC. The test results also showed significant strain localization in the gap at the bundle junctions along the bottom side of the channel, thus suggesting creep to be the main deformation mechanism for debris formation. An ABAQUS finite element model using two-dimensional beam elements with circular cross-section was developed to explain the experimental findings. A comparison of the calculated central sag (at mid-span), the axial displacement at the free end of the channel and the post-test sag profile showed good agreement with the experiments, when strain localization was included in the model, suggesting such a simple modelling approach would be adequate to explain the test findings. The results of the tests are important not only in the context of the validation of the analytical tools and models adopted by AECL for the severe accident analysis of CANDU reactors but

  5. Development of Operational Safety Monitoring System and Emergency Preparedness Advisory System for CANDU Reactors (I)

    International Nuclear Information System (INIS)

    Kim, Ma Woong; Shin, Hyeong Ki; Lee, Sang Kyu; Kim, Hyun Koon; Yoo, Kun Joong; Ryu, Yong Ho; Son, Han Seong; Song, Deok Yong

    2007-01-01

    As increase of operating nuclear power plants, an accident monitoring system is essential to ensure the operational safety of nuclear power plant. Thus, KINS has developed the Computerized Advisory System for a Radiological Emergency (CARE) system to monitor the operating status of nuclear power plant continuously. However, during the accidents or/and incidents some parameters could not be provided from the process computer of nuclear power plant to the CARE system due to limitation of To enhance the CARE system more effective for CANDU reactors, there is a need to provide complement the feature of the CARE in such a way to providing the operating parameters using to using safety analysis tool such as CANDU Integrated Safety Analysis System (CISAS) for CANDU reactors. In this study, to enhance the safety monitoring measurement two computerized systems such as a CANDU Operational Safety Monitoring System (COSMOS) and prototype of CANDU Emergency Preparedness Advisory System (CEPAS) are developed. This study introduces the two integrated safety monitoring system using the R and D products of the national mid- and long-term R and D such as CISAS and ISSAC code

  6. Steps to Advanced CANDU 600

    International Nuclear Information System (INIS)

    Oh, Yongshick; Brooks, G. L.

    1988-01-01

    The CANDU nuclear power system was developed from merging of AECL heavy water reactor technology with Ontario Hydro electrical power station expertise. The original four units of Ontario Hydro's Pickering Generating Station are the first full-scale commercial application of the CANDU system. AECL and Ontario Hydro then moved to the next evolutionary step, a more advanced larger scale design for four units at the Bruce Generating Station. CANDU 600 followed as a single unit nuclear electric power station design derived from an amalgam of features of the multiple unit Pickering and Bruce designs. The design of the CANDU 600 nuclear steam supply system is based on the Pickering design with improvements derived from the Bruce design. For example, most CANDU 600 auxiliary systems are based on Bruce systems, whereas the fuel handling system is based on the Pickering system. Four CANDU 600 units are in operation, and five are under construction in Romania. For the additional four units at Pickering Generating Station 'B', Ontario Hydro selected a replica of the Pickering 'A' design with limited design changes to maintain a high level of standardization across all eight units. Ontario Hydro applied a similar policy for the additional four units at Bruce Generating Station 'B'. For the four unit Darlington station, Ontario Hydro selected a design based on Bruce with improvements derived from operating experience, the CANDU 600 design and development programs

  7. Radioactive effluents from CANDU 6 reactors during normal operation

    International Nuclear Information System (INIS)

    Boss, C.R.; Allsop, P.J.

    1995-12-01

    During routine operation of a CANDU 6 reactor, various gaseous, liquid, and solid radioactive wastes are generated. The layout of the CANDU 6 reactor and the design of its systems ensure that these are minimized, but small quantities of gaseous and liquid wastes are continually discharged at very low concentrations. This report discusses the make-up of these chronically generated gaseous and liquid effluents. From a safety perspective, the doses to individual members of the public resulting from radioactive wastes chronically discharged from CANDU 6 reactors have been negligible. Similarly, doses to the regional and global populations have been negligible, generally less than 0.001% of background. While far below regulatory limits, releases of tritium, noble gases and gross β - -γ have been the most radiologically significant emissions, while radioiodine and particulates have had the greatest potential to deliver public dose. (author). 8 refs., 16 tabs., 3 figs

  8. CANDU-PHW fuel management

    International Nuclear Information System (INIS)

    Frescura, G.M.; Wight, A.L.

    1982-01-01

    This report covers the material presented in a series of six lectures at the Winter College on Nuclear Physics and Reactors held at the International Centre for Theoretical Physics in Trieste, Italy, Jan 22 - March 28, 1980. The report deals with fuel management in natural uranium fuelled CANDU-PHW reactors. Assuming that the reader has a basic knowledge of CANDU core physics, some of the reactor systems which are more closely related to fuelling are described. This is followed by a discussion of the methods used to calculate the power distribution and perform fuel management analyses for the equilibrium core. A brief description of some computer codes used in fuel management is given, together with an overview of the calculations required to provide parameters for core design and support the accident analysis. Fuel scheduling during approach to equilibrium and equilibrium is discussed. Fuel management during actual reactor operation is discussed with a review of the operating experience for some of the Ontario Hydro CANDU reactors. (author)

  9. Quality Products - The CANDU Approach

    International Nuclear Information System (INIS)

    Ingolfsrud, L. John

    1989-01-01

    The prime focus of the CANDU concept (natural uranium fuelled-heavy water moderated reactor) from the beginning has economy, heavy water losses and radiation exposures also were strong incentives for ensuring good design and reliable equipment. It was necessary to depart from previously accepted commercial standards and to adopt those now accepted in industries providing quality products. Also, through feedback from operating experience and specific design and development programs to eliminate problems and improve performance, CANDU has evolved into today's successful product and one from which future products will readily evolve. Many lessons have been learned along the way. On the one hand, short cuts of failures to understand basic requirements have been costly. On the other hand, sound engineering and quality equipment have yielded impressive economic advantages through superior performance and the avoidance of failures and their consequential costs. The achievement of lifetime economical performance demands quality products, good operation and good maintenance. This paper describes some of the basic approaches leading to high CANDU station reliability and overall excellent performance, particularly where difficulties have had to be overcome. Specific improvements in CANDU design and in such CANDU equipment as heat transport pumps, steam generators, valves, the reactor, fuelling machines and station computers, are described. The need for close collaboration among designers, nuclear laboratories, constructors, operators and industry is discussed. This paper has reviewed some of the key components in the CANDU system as a means of indicating the overall effort that is required to provide good designs and highly reliable equipment. This has required a significant investment in people and funding which has handsomely paid off in the excellent performance of CANDU stations. The close collaboration between Atomic Energy of Canada Limited, Canadian industry and the

  10. Joint studies on large CANDU

    International Nuclear Information System (INIS)

    Lee, Ikhwan; Yu, S. K. W.

    1994-01-01

    CANDU PHWRs have demonstrated generic benefits which will be continued in future designs. These include economic benefits due to low operating costs, business potential, strategic benefits due to fuel cycle flexibility and operational benefits. These benefits have been realized in Korea through the operation of Wolsong 1, resulting in further construction of PHWRs at the same site. The principal benefit, low electricity cost, is due to the high capacity factor and the low fuel cost for CANDU. The CANDU plant at Wolsong has proven to be a safe, reliable and economical electricity producer. The ability of PHWR to burn natural uranium ensures security of fuel supply. Following successful Technology Transfer via the Wolsong 2,3 and 4 project, future opportunity exists between Korea and Canada for continuing co-operation in research and development to improve the technology base, for product development partnerships, and business opportunities in marketing and building PHWR plants in third countries. High reliability, through excellent design, well-controlled operation, efficient maintenance and low operating costs is critical to the economic viability of nuclear plants. CANDU plants have an excellent performance record. The four operating CANDU 6 plants, operated by four utilities in three countries, are world performance leaders. The CANDU 9 design, with higher output capacity, will help to achieve better site utilization and lower electricity costs. Being an evolutionary design, CANDU 9 assures high performance by utilizing proven systems, and component designs adapted from operating CANDU plants (Bruce B, Darlington and CANDU 6). All system and operating parameters are within the operating proven range of current plants. KAERI and AECL have an agreement to perform joint studies on future PHWR development. The objective of the joint studies is to establish the requirements for the design of future advanced CANDU PHWR including the utility need for design improvements

  11. Corrosion control in CANDU nuclear power reactors

    International Nuclear Information System (INIS)

    Lesurf, J.E.

    1974-01-01

    Corrosion control in CANDU reactors which use pressurized heavy water (PHW) and boiling light water (BLW) coolants is discussed. Discussions are included on pressure tubes, primary water chemistry, fuel sheath oxidation and hydriding, and crud transport. It is noted that corrosion has not been a significant problem in CANDU nuclear power reactors which is a tribute to design, material selection, and chemistry control. This is particularly notable at the Pickering Nuclear Generating Station which will have four CANDU-PHW reactors of 540 MWe each. The net capacity factor for Pickering-I from first full power (May 1971) to March 1972 was 79.5 percent, and for Pickering II (first full power November 1971) to March 1972 was 83.5 percent. Pickering III has just reached full power operation (May 1972) and Pickering IV is still under construction. Gentilly CANDU-BLW reached full power operation in May 1972 after extensive commissioning tests at lower power levels with no major corrosion or chemistry problems appearing. Experience and operating data confirm that the value of careful attention to all aspects of corrosion control and augur well for future CANDU reactors. (U.S.)

  12. Economics of CANDU-PHW

    International Nuclear Information System (INIS)

    Jackson, H.A.; Woodhead, L.W.; Fanjoy, G.R.

    1984-03-01

    The CANDU-Pressurized Heavy Water (CANDU-PHW) type of nuclear-electric generating station has been developed jointly by Atomic Energy of Canada Limited and Ontario Hydro. This paper discusses the cost of producing electricity from CANDU, presents actual cost experience of CANDU and coal in Ontario, presents projected CANDU and coal costs in Ontario and compares CANDU and Light Water Reactor cost estimates in Ontario

  13. Economics of CANDU-PHW

    International Nuclear Information System (INIS)

    McConnell, L.G.; Woodhead, L.W.; Fanjoy, G.R.

    1982-03-01

    The CANDU-Pressurized Heavy Water (CANDU-PHW) type of nuclear-electric generating station has been developed jointly by Atomic Energy of Canada Limited and Ontario Hydro. This paper discusses the cost of producing electricity from CANDU, presents actual cost experience of CANDU and coal in Ontario, presents projected CANDU and coal costs in Ontario and compares CANDU and Light Water Reactor cost estimates in Ontario

  14. Economics of CANDU-PHW

    International Nuclear Information System (INIS)

    Jackson, H.A.; Horton, E.P.; Woodhead, L.W.; Fanjoy, G.R.

    1985-03-01

    The CANDU-Pressurized Heavy Water (CANDU-PHW) type of nuclear-electric generating station has been developed jointly by Atomic Energy of Canada Limited and Ontario Hydro. This paper discusses the cost of producing electricity from CANDU, presents actual cost experience of CANDU and coal in Ontario, presents projected CANDU and coal costs in Ontario and compares CANDU and Light Water Reactor cost estimates in Ontario

  15. CANDU reactors. Experience and innovation

    International Nuclear Information System (INIS)

    Hart, R.S.; Brooks, G.L.

    1989-02-01

    The title of this paper highlights two key considerations which must be properly balanced through good management in the evolution of any engineering product. Excessive reliance on experience will lead to product stagnation; excessive reliance on innovation will often lead to an unsatisfactory product, at least in the first generation of this product. To illustrate this balancing process, the paper reviews CANDU evolution and experience and the balance between proveness and innovation achieved through management of the evolution process from early prototypes to today's large-scale commercial units. A forecast of continuing evolutionary directions is included

  16. Candu reactors - experience and innovation

    International Nuclear Information System (INIS)

    Hart, R.S.; Brooks, G.L.

    1989-01-01

    The title of this paper highlights two key considerations which must be properly balanced through good management in the evolution of any engineering product. Excessive reliance on experience will lead to product stagnation; excessive reliance on innovation will often lead to an unsatisfactory product, at least in the first generation of this product. To illustrate this balancing process, the paper reviews CANDU evolution and experience and the balance between proveness and innovation achieved through management of the evolution process from early prototypes to today's large-scale commercial units. A forecast of continuing evolutionary directions is included

  17. Establishment of Safety Analysis System and Technology for CANDU Reactors

    International Nuclear Information System (INIS)

    Park, Joo Hwan; Rhee, B. W.; Min, B. J.; Kim, H. T.; Kim, W. Y.; Yoon, C.; Chun, J. S.; Cho, M. S.; Jeong, J. Y.; Kang, H. S.

    2007-06-01

    The following 4 research items have been studied to establish a CANDU safety analysis system and to develop the relevant elementary technology for CANDU reactors. First, to improve and validate the CANDU design and operational safety analysis codes, the CANDU physics cell code WIMS-CANDU was improved, and validated, and an analysis of the moderator subcooling and pressure tube integrity has been performed for the large break LOCAs without ECCS. Also a CATHENA model and a CFD model for a post-blowdown fuel channel analysis have been developed and validated against two high temperature thermal-chemical experiments, CS28-1 and 2. Second, to improve the integrated operating system of the CANDU safety analysis codes, an extension has been made to them to include the core and fuel accident analyses, and a web-based CANDU database, CANTHIS version 2.0 was completed. Third, to assess the applicability of the ACR-7 safety analysis methodology to CANDU-6 the ACR-7 safety analysis methods were reviewed and the safety analysis methods of ACR-7 applicable to CANDU-6 were recommended. Last, to supplement and improve the existing CANDU safety analysis procedures, detailed analysis procedures have been prepared for individual accident scenarios. The results of this study can be used to resolve the CANDU safety issues, to improve the current design and operational safety analysis codes, and to technically support the Wolsong site to resolve their problems

  18. Trends in the capital costs of CANDU generating stations

    International Nuclear Information System (INIS)

    Yu, A.M.

    1982-09-01

    This paper consolidates the actual cost experience gained by Atomic Energy of Canada Limited, Ontario Hydro, and other Canadian electric utlities in the planning, design and construction of CANDU-PHWR (CANada Deuterium Uranium-Pressurized Heavy Water Reactor) generating stations over the past 30 years. For each of the major CANDU-PHWR generating stations in operation and under construction in Canada, an analysis is made to trace the evolution of the capital cost estimates. Major technical, economic and other parameters that affect the cost trends of CANDU-PHWR generating stations are identified and their impacts assessed. An analysis of the real cost of CANDU generating stations is made by eliminating interest during construction and escalation, and the effects of planned deferment of in-service dates. An historical trend in the increase in the real cost of CANDU power plants is established. Based on the cost experience gained in the design and construction of CANDU-PHWR units in Canada, as well as on the assessment of parameters that influence the costs of such projects, the future costs of CANDU-PHWRs are presented

  19. The back end of the fuel cycle and CANDU

    International Nuclear Information System (INIS)

    Allan, C.J.; Dormuth, K.W.

    2001-01-01

    CANDU reactor operators have benefited from several advantages of the CANDU system and from AECL's experience, with regard to spent fuel handling, storage and disposal. AECL has over 20 years experience in development and application of medium-term storage and research and development on the disposal of used fuel. As a result of AECL's experience, short-term and medium-term storage and the associated handling of spent CANDU fuel are well proven and economic, with an extremely high degree of public and environmental protection. In fact, both short-term (water-pool) and medium-term (dry canister) storage of CANDU fuel are comparable or lower in cost per unit of energy than for PWRs. Both pool storage and dry spent fuel storage are fully proven, with many years of successful, safe operating experience. AECL's extensive R and D on the permanent disposal of spent-fuel has resulted in a defined concept for Canadian fuel disposal in crystalline rock. This concept was recently confirmed as ''technically acceptable'' by an independent environmental review panel. Thus, the Canadian program represents an international demonstration of the feasibility and safety of geological disposal of nuclear fuel waste. Much of the technology behind the Canadian concept can be adapted to permanent land-based disposal strategies chosen by other countries. In addition, the Canadian development has established a baseline for CANDU fuel permanent disposal costs. Canadian and international work has shown that the cost of permanent CANDU fuel disposal is similar to the cost of LWR fuel disposal per unit of electricity produced. (author)

  20. Technology transfer: The CANDU approach

    International Nuclear Information System (INIS)

    Hart, R.S.

    1998-01-01

    The many and diverse technologies necessary for the design, construction licensing and operation of a nuclear power plant can be efficiently assimilated by a recipient country through an effective technology transfer program supported by the firm long term commitment of both the recipient country organizations and the supplier. AECL's experience with nuclear related technology transfer spans four decades and includes the construction and operation of CANDU plants in five countries and four continents. A sixth country will be added to this list with the start of construction of two CANDU 6 plants in China in early 1997. This background provides the basis for addressing the key factors in the successful transfer of nuclear technology, providing insights into the lessons learned and introducing a framework for success. This paper provides an overview of AECL experience relative to the important factors influencing technology transfer, and reviews specific country experiences. (author)

  1. CANDU steam generator life management

    International Nuclear Information System (INIS)

    Tapping, R.L.; Nickerson, J.; Spekkens, P.; Maruska, C.

    1998-01-01

    Steam generators are a critical component of a nuclear power reactor, and can contribute significantly to station unavailability, as has been amply demonstrated in Pressurized Water Reactors (PWRs). CANDU steam generators are not immune to steam generator degradation, and the variety of CANDU steam generator designs and tube materials has led to some unexpected challenges. However, aggressive remedial actions, and careful proactive maintenance activities, have led to a decrease in steam generator-related station unavailability of Canadian CANDUs. AECL and the CANDU utilities have defined programs that will enable existing or new steam generators to operate effectively for 40 years. Research and development work covers corrosion and mechanical degradation of tube bundles and internals, chemistry, thermalhydraulics, fouling, inspection and cleaning, as well as provision for specially tool development for specific problem solving. A major driving force is development of CANDU-specific fitness-for-service guidelines, including appropriate inspection and monitoring technology to measure steam generator condition. Longer-range work focuses on development of intelligent on-line monitoring for the feedwater system and steam generator. New designs have reduced risk of corrosion and fouling, are more easily inspected and cleaned, and are less susceptible to mechanical damage. The Canadian CANDU utilities have developed programs for remedial actions to combat degradation of performance (Gentilly-2, Point Lepreau, Bruce A/B, Pickering A/B), and have developed strategic plans to ensure that good future operation is ensured. The research and development program, as well as operating experience, has identified where improvements in operating practices and/or designs can be made in order to ensure steam generator design life at an acceptable capacity factory. (author)

  2. Valve maintainability in CANDU-PHW nuclear generating stations

    International Nuclear Information System (INIS)

    Pothier, N.E.; Crago, W.A.

    1977-09-01

    Design, application, layout and administrative factors which affect valve maintainability in CANDU-PHW power reactors are identified and discussed. Some of these are illustrated by examples based on prototype reactor operation experience. Valve maintainability improvements resulting from laboratory development and maintainability analysis, have been incorporated in commercial CANDU-PHW nuclear generating stations. These, also, are discussed and illustrated. (author)

  3. An integrated CANDU system

    International Nuclear Information System (INIS)

    Donnelly, J.

    1982-09-01

    Twenty years of experience have shown that the early choices of heavy water as moderator and natural uranium as fuel imposed a discipline on CANDU design that has led to outstanding performance. The integrated structure of the industry in Canada, incorporating development, design, supply, manufacturing, and operation functions, has reinforced this performance and has provided a basis on which to continue development in the future. These same fundamental characteristics of the CANDU program open up propsects for further improvements in economy and resource utilization through increased reactor size and the development of the thorium fuel cycle

  4. CANDU 3000

    International Nuclear Information System (INIS)

    Keillor, Mac

    1987-01-01

    In this article, the CANDU 300 design, and the team that designed it, are featured. The CANDU 300 will operate at an energy cost similar to that of the larger CANDU units, but is sized for emerging markets. Ease of construction is an important feature: for example, full 360-degree access is available to each of the five buildings during construction; and the whole plant consists of about 90 modules, which can be built in separate locations, and hoisted into place

  5. CANDU steam generator life management: laboratory data and plant experience

    International Nuclear Information System (INIS)

    Tapping, R.L.; Nickerson, J.H.; Subash, N.; Wright, M.D.

    2001-10-01

    As CANDU reactors enter middle age, and the potential value of the plants in a deregulated market is realized, life management and life extension issues become increasingly important. An accurate assessment of critical components, such as the CANDU 6 steam generators (SGs), is crucial for successful life extension, and in this context, material issues are a key factor. For example, service experience with Alloy 900 tubing indicates very low levels of degradation within CANDU SGs; the same is also noted worldwide. With little field data for extrapolation, life management and life extension decisions for the tube bundles rely heavily on laboratory data. Similarly, other components of the SGs, in particular the secondary side internals, have only limited inspection data upon which to base a condition assessment. However, in this case there are also relatively little laboratory data. Decisions on life management and life extension are further complicated--not only is inspection access often restricted, but repair or replacement options for internal components are, by definition, also limited. The application of CANDU SG life management and life extension requires a judicious blend of in-service data, laboratory research and development (R and D) and materials and engineering judgment. For instance, the available laboratory corrosion and fretting wear data for Alloy 800 SG tubing have been compared with plant experience (with all types of tubing), and with crevice chemistry simulations, in order to provide an appropriate inspection guide for a 50-year SG life. A similar approach has been taken with other SG components, where the emphasis has been on known degradation mechanisms worldwide. This paper provides an outline of the CANDU SG life management program, including the results to date, a summary of the supporting R and D program showing the integration with condition assessment and life management activities, and the approach taken to life extension for a typical

  6. A three-dimensional operational transient simulation of the CANDU core with typical reactor regulating system

    Energy Technology Data Exchange (ETDEWEB)

    Yeom, Choong Sub; Kim, Hyun Dae; Park, Kyung Seok; Park, Jong Woon [Institute for Advanced Engineering, Taejon (Korea, Republic of)

    1995-07-01

    This paper describes the results of simulation of a CANDU operational transient problem (re-startup after short shutdown) using the Coupled Reactor Kinetics(CRKIN) code developed previously with CANDU Reactor Regulating System (RRS) logic. The performance in the simulation is focused on investigating the behaviours of neutron power and regulating devices in accordance with the changes of xenon concentration following the operation of the RRS.

  7. Wet steam turbines for CANDU-Reactors

    International Nuclear Information System (INIS)

    Westmacott, C.H.L.

    1977-01-01

    The technical characteristics of 4 wet steam turbine aggregates used in the Pickering nuclear power station are reported on along with operational experience. So far, the general experience was positive. Furthermore, plans are mentioned to use this type of turbines in other CANDU reactors. (UA) [de

  8. CANDU advanced fuel cycles

    International Nuclear Information System (INIS)

    Slater, J.B.

    1986-03-01

    This report is based on informal lectures and presentations made on CANDU Advanced Fuel Cycles over the past year or so, and discusses the future role of CANDU in the changing environment for the Canadian and international nuclear power industry. The changing perspectives of the past decade lead to the conclusion that a significant future market for a CANDU advanced thermal reactor will exist for many decades. Such a reactor could operate in a stand-alone strategy or integrate with a mixed CANDU-LWR or CANDU-FBR strategy. The consistent design focus of CANDU on enhanced efficiency of resource utilization combined with a simple technology to achieve economic targets, will provide sufficient flexibility to maintain CANDU as a viable power producer for both the medium- and long-term future

  9. The CANDU 80

    International Nuclear Information System (INIS)

    Hart, R.S.

    1998-01-01

    AECL has completed the conceptual design of a small CANDU plant with an output, in the range of 300 MWth (called the CANDU 80), suitable for a variety of electrical and co-generation applications including desalination, oil sands oil extraction and processing, and the provision of electricity and heat to areas with low demand. This paper provides a brief overview of the CANDU 80, and discusses key features contributing to safety and operational margins

  10. Enhanced CANDU 6 Reactor

    International Nuclear Information System (INIS)

    Azeez, S.; Alizadeh, A.; Girouard, P.

    2005-01-01

    Full text: The CANDU 6 power reactor is visionary in its approach, remarkable for its on-power refuelling capability and proven over years of safe, economical and reliable power production. Developed by Atomic Energy of Canada Ltd, the CANDU 6 design offers excellent performance utilizing state-of-the-art technology. The first CANDU 6 plants went into service in the early 1980's as leading edge technology and the design has been continuously advanced to maintain superior performance with an outstanding safety record. The first CANDU 6 plants- Gentilly 2 and Point Lepreau in Canada, Embalse in Argentina and Wolsong- Unit 1 in Korea have been in service for more than 21 years and are still producing electricity at peak performance and to the end of 2004, their average lifetime Capacity Factor was 83.2%. The newer CANDU 6 units in Romania (Cernavoda 1), Korea (Wolsong-Units 2, 3 and 4) and Qinshan (Phase III- Units 1 and 2) have also been performing at outstanding levels. The average lifetime Capacity Factor of the 10 CANDU 6 operating units around the world has been 87% to the end of 2004. Building on these successes, AECL is committed to the further development of this highly successful design, now focussing on meeting customer's needs for reduced costs, further improvements to plant operation and performance, enhanced safety and incorporating up-to-date technology as warranted. This has resulted in AECL embarking on improving the CANDU 6 design through an upgraded product termed as the 'Enhanced CANDU 6' (EC6)- which incorporates several attractive but proven features that will make the CANDU 6 reactor even more economical, safer and easier to operate. Some of the key features that will be incorporated in the EC6 include increasing the plant's power output, shortening the overall project schedule, decreasing the capital cost, dealing with obsolescence issues, optimizing maintenance outages and incorporating lessons learnt through feedback obtained from the

  11. CANDU fuel - fifteen years of power reactor experience

    International Nuclear Information System (INIS)

    Fanjoy, G.R.; Bain, A.S.

    1977-05-01

    Analyses of performance statistics, supplemented by examinations of fuel from power reactors and experimental loops have yielded: (a) a thorough understanding of the fundamental behaviour of CANDU fuel; (b) data showing that the predicted high utilization of uranium has been achieved; (c) criteria for operation, which have led to the current very low defect rate of 0.03% of all assemblies and to 'CANLUB' fuel, which has a graphite interlayer between the fuel and sheath to reduce defects on power increases; (d) proof that the short length (500 mm), collapsible cladding features of the CANDU bundle are successful and that the fuel can operate at high-power output (current peak outer-element linear power is 58 +- 15% kW/m). As of mid-1976 over 3 x 10 6 individual elements have been built and over 2 x 10 6 elements have been irradiated. Only six defects have been attributed to faulty materials or fabrication, and the use of high-density UO 2 with low-moisture content precluded defects from hydrogen contamination and densification

  12. Operation of CANDU power reactor in thorium self-sufficient fuel cycle

    Indian Academy of Sciences (India)

    This paper presents the results of calculations for CANDU reactor operation in thorium fuel cycle. Calculations are performed to estimate the feasibility of operation of heavy-water thermal neutron power reactor in self-sufficient thorium cycle. Parameters of active core and scheme of fuel reloading were considered to be the ...

  13. Conference proceedings of the 4. international conference on CANDU fuel. V. 1,2

    International Nuclear Information System (INIS)

    1995-01-01

    These proceedings contain the full texts of all 65 papers presented at the 4th International Conference on CANDU fuel. As such, they represent an update on the state-of-the-art in such important CANDU fuel topics as International Development Programs and Operating Experience with CANDU fuel, Performance Assessments and Fuel Behavior Modeling, Fuel Properties, Licensing and Accident Analyses for CANDU fuel, Design, Testing and Manufacturing, and Advanced Fuel Designs. The large number of papers required the use of parallel sessions for the first time at a CANDU Fuel Conference

  14. Conference proceedings of the 4. international conference on CANDU fuel. V. 1,2

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1996-12-31

    These proceedings contain the full texts of all 65 papers presented at the 4th International Conference on CANDU fuel. As such, they represent an update on the state-of-the-art in such important CANDU fuel topics as International Development Programs and Operating Experience with CANDU fuel, Performance Assessments and Fuel Behavior Modeling, Fuel Properties, Licensing and Accident Analyses for CANDU fuel, Design, Testing and Manufacturing, and Advanced Fuel Designs. The large number of papers required the use of parallel sessions for the first time at a CANDU Fuel Conference.

  15. Analysis of Multiple Spurious Operation Scenarios for Decay Heat Removal Function of CANDU Reactors

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Youngseung; Bae, Yeon-kyoung; Kim, Myungsu [KHNP CRI, Daejeon (Korea, Republic of)

    2016-10-15

    The worst fire broke out in the Browns Ferry Nuclear Power Plant on March 22, 1975. A fire occurrence in a nuclear power plant has recognized a latently serious incident. Nuclear power plants should achieve and maintain the safe shutdown conditions during and after the occurrence of a fire. Functions of the safe shutdown are five such as the shutdown function, the decay heat removal function, the containment function, monitoring and control function, and the supporting function for CANDU type reactors. The purpose of this paper is to analyze that the decay heat removal function of the safe shutdown functions for CANDU type reactors is achieved under the fire induced multiple spurious operation. The scenarios of the fire induced multiple spurious operations (MSO) for the systems used for the decay heat cooling were analyzed. Additionally, Integrated Severe Accident Analysis code for CANDU plants (ISAAC) for determining success criteria of thermal hydraulic analysis was used. Decay heat cooling systems of CANDU reactors are the auxiliary feedwater system, the emergency water supply system, and the shutdown cooling system. A big fire can threat the safety of nuclear power plants, and safe shutdown conditions. The regulatory body in Korea requires the fire hazard analysis including fire induced MSOs. The safe shutdown functions for CANDU reactors are the shutdown function, the decay heat removal function, the containment function, the monitoring and control function, and the supporting service function. The number of spurious operations for the auxiliary feedwater system is more than six and that for the emergency water supply system is one. Additionally, misoperations for the shutdown cooling system are more than two. Accordingly, if total nine components could be spuriously operated, the decay heat removal function would be lost entirely.

  16. Analysis of Multiple Spurious Operation Scenarios for Decay Heat Removal Function of CANDU Reactors

    International Nuclear Information System (INIS)

    Lee, Youngseung; Bae, Yeon-kyoung; Kim, Myungsu

    2016-01-01

    The worst fire broke out in the Browns Ferry Nuclear Power Plant on March 22, 1975. A fire occurrence in a nuclear power plant has recognized a latently serious incident. Nuclear power plants should achieve and maintain the safe shutdown conditions during and after the occurrence of a fire. Functions of the safe shutdown are five such as the shutdown function, the decay heat removal function, the containment function, monitoring and control function, and the supporting function for CANDU type reactors. The purpose of this paper is to analyze that the decay heat removal function of the safe shutdown functions for CANDU type reactors is achieved under the fire induced multiple spurious operation. The scenarios of the fire induced multiple spurious operations (MSO) for the systems used for the decay heat cooling were analyzed. Additionally, Integrated Severe Accident Analysis code for CANDU plants (ISAAC) for determining success criteria of thermal hydraulic analysis was used. Decay heat cooling systems of CANDU reactors are the auxiliary feedwater system, the emergency water supply system, and the shutdown cooling system. A big fire can threat the safety of nuclear power plants, and safe shutdown conditions. The regulatory body in Korea requires the fire hazard analysis including fire induced MSOs. The safe shutdown functions for CANDU reactors are the shutdown function, the decay heat removal function, the containment function, the monitoring and control function, and the supporting service function. The number of spurious operations for the auxiliary feedwater system is more than six and that for the emergency water supply system is one. Additionally, misoperations for the shutdown cooling system are more than two. Accordingly, if total nine components could be spuriously operated, the decay heat removal function would be lost entirely

  17. Fuel deposits, chemistry and CANDU reactor operation

    International Nuclear Information System (INIS)

    Roberts, J.G.

    2013-01-01

    'Hot conditioning' is a process which occurs as part of commissioning and initial start-up of each CANDU reactor, the first being the Nuclear Power Demonstration-2 reactor (NPD). Later, understanding of the cause of the failure of the Pickering Unit 1 G16 fuel channel led to a revised approach to 'hot conditioning', initially demonstrated on Bruce Unit 5, and subsequently utilized for each CANDU unit since. The difference being that during 'hot conditioning' of CANDU heat transport systems fuel was not in-core until Bruce Unit 5. The 'hot conditioning' processes will be briefly described along with the consequences to fuel. (author)

  18. Heat sink management during CANDU low level operation

    International Nuclear Information System (INIS)

    Wang Liansheng

    2008-01-01

    This paper introduces the practice of low-level operation with opening on the main heat transport system during an outage for a Candu-6 nuclear power plant, analyses the risks of losing heat sink during this condition, and points out the safety measures and management requirement for controlling such risks. This paper can be used as a reference for improving and optimizing the heat sink management for the coming outages. (author)

  19. Enhancing plant performance in newer CANDU plants utilizing PLiM methodologies

    International Nuclear Information System (INIS)

    Azeez, S.; Krishnan, V.S.; Nickerson, J.H.; Kakaria, B.

    2002-01-01

    Over the past 5 years, Atomic Energy of Canada Ltd. (AECL) has been working with CANDU utilities on comprehensive and integrated CANDU PLiM programs for successful and reliable operation through design life and beyond. Considerable progress has been made in the development of CANDU PLiM methodologies and implementation of the outcomes at the plants. The basis of CANDU PLiM programs is to understand the ageing degradation mechanisms, prevent/minimize the effects of these phenomena in the Critical Structures, Systems and Components (CSSCs), and maintain the CSSC condition as close as possible in the best operating condition. Effective plant practices in surveillance, maintenance, and operations are the primary means of managing ageing. From the experience to date, the CANDU PLiM program will modify and enhance, but not likely replace, existing plant programs that address ageing. However, a successful PLiM program will provide assurance that these existing plant programs are both effective and can be shown to be effective, in managing ageing. This requires a structured and managed approach to both the assessment and implementation processes

  20. Emergency core cooling strainers-the Candu experience

    International Nuclear Information System (INIS)

    Eyvindson, A.; Rhodes, D.; Carson, P.; Makdessi, G.

    2004-01-01

    The Canadian nuclear industry, including Atomic Energy of Canada Limited (AECL) and the four nuclear utilities (New Brunswick Power, Hydro-Quebec, Ontario Power Generation and Bruce Power) have been heavily involved in strainer clogging issues since the late 1990's. A substantial knowledge base has been obtained with support from various organisations, including the CANDU Owners Group (COG), AECL and the CANDU utilities. Work has included debris assessments at specific stations, debris characterisation, transport, head loss measurements across strainers, head loss models and investigations into paints and coatings. Much of this work was performed at AECL's Chalk River Laboratories and has been used to customize strainer solutions for several CANDU (PWR-type) stations. This paper summarises the CANDU experience, describing problems encountered and lessons learned from strainer implementation at stations. Between 1999 and 2003, AECL supplied strainers to six different CANDU stations, representing 12 units with a total power output of approximately 8.2 GWe. Each station had unique needs with respect to layout, effective area, allowable head loss and installation schedule. Challenges at various sites included installation in a covered trench with single-point access, allowing for field adjustments to accommodate large variations in floor level and pump suction location, on-power installation, very high levels of particulate relative to fibrous debris, and relatively low allowable head loss. The following are key points to consider during any station assessment or strainer implementation: - a realistic testing model and method is essential for accurate predictions of head loss, and the limits of the model must be understood; - assessment of station debris must be sufficiently conservative to overcome uncertainties in debris generation and transport models; - appropriate and reliable data (e.g. flow rate, layout, size of test model, method of debris generation and

  1. Korean experience in CANDU-PHWR operation

    International Nuclear Information System (INIS)

    Sang-kee Park

    1987-01-01

    Among KEPCO's 9 nuclear power units, Korea Nuclear Unit No. 3, the Wolsung Nuclear Power Plant is the only CANDU-PHWR Unit, while the rest of 8 others are PWR units. The unit was designed by Atomic Energy of Canada, Ltd(AECL) of Canada, who also perfomed overall project management for the plant construction under the provisions and arrangement of the relevant contracts. The gross electrical output of the plant is 678.7 MWe and thermal output of the reactor is 2061 MWth. While these figures lead to lower plant eficiency than LWR counterparts, unit energy cost for fuel is more favorable than LWRs because natural uranium is utilized for the fuel bundles, some of which are already being fabricated domestically. Annual capacity factors for 1983 and 1984 could have been improved, if two major planned outages for the modification works on steam generator internals and one major forced outage form the heavy water spill incident could be eliminated. The heavy water spill incident in November, 1984 brought plant staffs many lessons to learn and many things to contemplate. Unique design concepts and features such as on-power refuelling, poison prevent mode, versatile plant control system built around digital computers and power step back/set back logics may be credited for these relatively good plant performances. Human related factors such as staff's technical capabilities and strong will toward good performance were other elements which could not be overlooked

  2. Korean experience in CANDU-PHWR operation

    International Nuclear Information System (INIS)

    Park, S.K.

    1988-01-01

    Among KEPCO's 9 nuclear power units, Korea Nuclear Unit No. 3, the Wolsung Nuclear Power Plant is the only CANDU-PHWR Unit, while the rest of 8 others are PWR units. The unit was designed by Atomic Energy of Canada, Ltd. of Canada, who also performed overall project management for the plant construction under the provisions and arrangement of the relevant contracts. The gross electrical output of the plant is 678.7 MWe and thermal output of the reactor is 2061 MWth. While these figures lead to lower plant efficiency than LWR counterparts, unit energy cost for fuel is more favorable than LWRs because natural uranium is utilized for the fuel bundles, some of which are already being fabricated domestically. Annual capacity factors for 1983 and 1984 could have been improved, if two major planned outages for the modification works on steam generator internals and one major forced outage from the heavy water spill incident could be eliminated. The heavy water spill incident in November, 1984 brought plant staffs many lessons to learn and many things to contemplate. Unique design concepts and features such as on-power refuelling, poison prevent mode, versatile plant control system built around digital computers and power step back/set back logics may be credited for these relatively good plant performances. Human related factors such as staff's technical capabilities and strong will toward good performance were other elements which could not be overlooked

  3. Next generation CANDU plants

    International Nuclear Information System (INIS)

    Hedges, K.R.; Yu, S.K.W.

    1998-01-01

    Future CANDU designs will continue to meet the emerging design and performance requirements expected by the operating utilities. The next generation CANDU products will integrate new technologies into both the product features as well as into the engineering and construction work processes associated with delivering the products. The timely incorporation of advanced design features is the approach adopted for the development of the next generation of CANDU. AECL's current products consist of 700MW Class CANDU 6 and 900 MW Class CANDU 9. Evolutionary improvements are continuing with our CANDU products to enhance their adaptability to meet customers ever increasing need for higher output. Our key product drivers are for improved safety, environmental protection and improved cost effectiveness. Towards these goals we have made excellent progress in Research and Development and our investments are continuing in areas such as fuel channels and passive safety. Our long term focus is utilizing the fuel cycle flexibility of CANDU reactors as part of the long term energy mix

  4. CANDU technology for generation III + AND IV reactors

    International Nuclear Information System (INIS)

    Torgerson, D.F.

    2005-01-01

    Atomic Energy of Canada Limited (AECL) is the original developer of the CANDU?reactor, one of the three major commercial power reactor designs now used throughout the world. For over 60 years, AECL has continued to evolve the CANDU design from the CANDU prototypes in the 1950s and 1960s through to the second generation reactors now in operation, including the Generation II+ CANDU 6. The next phase of this evolution, the Generation III+ Advanced CANDU ReactorTM (ACRTM), continues the strategy of basing next generation technology on existing CANDU reactors. Beyond the ACR, AECL is developing the Generation IV CANDU Super Critical Water Reactor. Owing to the evolutionary nature of these advanced reactors, advanced technology from the development programs is also being applied to operating CANDU plants, for both refurbishments and upgrading of existing systems and components. In addition, AECL is developing advanced technology that covers the entire life cycle of the CANDU plant, including waste management and decommissioning. Thus, AECL maintains state-of-the-art expertise and technology to support both operating and future CANDU plants. This paper outlines the scale of the current core knowledge base that is the foundation for advancement and support of CANDU technology. The knowledge base includes advancements in materials, fuel, safety, plant operations, components and systems, environmental technology, waste management, and construction. Our approach in each of these areas is to develop the underlying science, carry out integrated engineering scale tests, and perform large-scale demonstration testing. AECL has comprehensive R and D and engineering development programs to cover all of these elements. The paper will show how the ongoing expansion of the CANDU knowledge base has led to the development of the Advanced CANDU Reactor. The ACR is a Generation III+ reactor with substantially reduced costs, faster construction, and enhanced passive safety and operating

  5. CANDU steam generator aging management: Some perspectives after 20 years in-service experience

    International Nuclear Information System (INIS)

    Tapping, R.I.; Nickerson, J.; Subash, N.; Roy, S.

    2002-01-01

    assessment of the future field data. Subtle changes to plant operation and also the unique plant-specific details of materials and design often can have a significant impact on the life capability of this complicated equipment. From the plant-specific assessments, and from the experience from our R and D program and utility interaction, AECL has developed a detailed proactive SG aging management strategy for long and reliable life capability (to 50 years). This proactive strategy has a number of important elements that are recommended to be incorporated into current plant programs. With CANDU plants continuing operation with aging equipment, such as steam generators, AECL is continuing to undertake comprehensive programs to support operations and provide enhanced technologies for performance attainment and improvement in inspection, surveillance and performance/safety analysis methodologies. These technologies are also continuously improved by programs that are targeted to important in-service degradation mechanisms, understanding of the system/equipment tolerance to this degradation, and to measures that can be applied to both new reactors and back fitted to existing plants. Systematic and continuous feedback of experience from operations to the performance programs is another important part of the approach. This paper will outline the results of several CANDU SG condition assessments, and place the recommendations from these assessments in context with effective aging Management programs that need to be followed to achieve economic life. For CANDU 6 utilities, which have had a very good steam generator service record with little or no significant active degradation to date, the paper will outline the approach to proactive aging Management that will see equipment through to long and reliable extended life. Also mentioned will be examples of AECL performance improvement and operations support programs for steam generators. (author)

  6. Recent experience related to neutronic transients in Ontario Hydro CANDU nuclear generating stations

    International Nuclear Information System (INIS)

    Frescura, G.M.; Smith, A.J.; Lau, J.H.

    1991-01-01

    Ontario Hydro presently operates 18 CANDU reactors in the province of Ontario, Canada. All of these reactors are of the CANDU Pressurized Heavy Water design, although their design features differ somewhat reflecting the evolution that has taken place from 1971 when the first Pickering unit started operation to the present as the Darlington units are being placed in service. Over the last three years, two significant neutronic transients took place at the Pickering Nuclear Generating Station 'A' (NGS A) one of which resulted in a number of fuel failures. Both events provided valuable lessons in the areas of operational safety, fuel performance And accident analysis. The events and the lessons learned are discussed in this paper

  7. Economic case for CANDU life extension projects

    International Nuclear Information System (INIS)

    Qureshi, S.; Tenev, T.; Lewi, M.

    2014-01-01

    As CANDU reactors approach their original end of design life utilities are faced with two options: to extend the operating life of the reactor by undergoing a life extension project (LEP), or to commence decommissioning activities. Recent project experience has shown that there is economic merit in extending the life of the operating reactor. There are many benefits to such a decision, the most obvious being the revenue that will be generated from the additional years of electricity production by the utility. Delays in decommissioning are also advantageous since the large costs associated with such a long-term activity are pushed into the future, thereby decreasing the net present value (NPV) of the investment. In addition, relatively few power reactors have been fully decommissioned to date and deferring this activity transfers the associated risks to others that are currently obligated to undertake decommissioning activities sooner. Candu Energy has been involved with the life extension projects of the following CANDU reactors: Point Lepreau (New Brunswick, Canada), Bruce Unit 1 and Unit 2 (Ontario, Canada), and Wolsong Unit 1 (South Korea). These reactors underwent fuel channel replacement programs in addition to replacement of major reactor components. Most recently, both Ontario Power Generation (OPG) and Nucleoelectrica Argentina Sociedad Anonima (NA-SA) have commenced work on life extension projects at the Darlington (Canada) and Embalse (Argentina) sites respectively. The experience gained from previous LEP projects allows Candu Energy to deliver future projects in a timely, efficient, and cost effective manner. (author)

  8. Enhanced candu 6 reactor: status

    International Nuclear Information System (INIS)

    Azeez, S.; Girouard, P.

    2006-01-01

    The CANDU 6 power reactor is visionary in its approach, renowned for its on-power refuelling capability and proven over years of safe, economical and reliable power production. Developed by Atomic Energy of Canada Limited (AECL), the CANDU 6 design offers excellent performance utilizing state-of-the-art technology. The first CANDU 6 plants went into service in the early 1980s as leading edge technology and the design has been continuously advanced to maintain superior performance with an outstanding safety record. The first set of CANDU 6 plants - Gentilly 2 and Point Lepreau in Canada, Embalse in Argentina and Wolsong- Unit 1 in Korea - have been in service for more than 22 years and are still producing electricity at peak performance; to the end of 2004, their average Lifetime Capacity Factor was 83.2%. The newer CANDU 6 units in Romania (Cernavoda 1), Korea (Wolsong-Units 2, 3 and 4) and Qinshan (Phase III- Units 1 and 2) have also been performing at outstanding levels. The average lifetime Capacity Factor of the 10 CANDU 6 operating units around the world has been 87% to the end of 2004. Building on these successes, AECL is committed to the further development of this highly successful design, now focussing on meeting customers' needs for reduced costs, further improvements to plant operation and performance, enhanced safety and incorporating up-to-date technology, as warranted. This has resulted in AECL embarking on improving the CANDU 6 design through an upgraded product termed the ''Enhanced CANDU 6'' (EC6), which incorporates several attractive but proven features that make the CANDU 6 reactor even more economical, safer and easier to operate. Some of the key features that are being incorporated into the EC6 include increasing the plant's power output, shortening the overall project schedule, decreasing the capital cost, dealing with obsolescence issues, optimizing maintenance outages and incorporating lessons learnt through feedback obtained from the

  9. CANDU - Canadian experience and expectations with the heavy-water reactor

    International Nuclear Information System (INIS)

    Foster, J.S.; Russell, S.H.

    1977-05-01

    The paper describes the evolution of the CANDU nuclear-power plants with particular reference to the objectives of safety, reliability and economy; the development of industrial capacity for the supply of fuel, components and heavy water; and the prospective development of advanced fuel cycles and the projected results. It provides data on radiation, releases, and exposures, internal and external to the power plants; plant availability, capacity factors and other performance data; heavy water production data with reference to safety, reliability, and economics; projections of the performance of CANDU reactors operating on a thorium-U-233 cycle and the development required to establish this cycle; and intent with respct to spent-fuel management and radioactive-waste storage. (author)

  10. Eddy Currents Inspection of CANDU Steam Generator Tubes using Zetec's ZR-1 Robot. Experience in Romania

    International Nuclear Information System (INIS)

    Scott Hower; Luiza Vladu; Adrian Nichisov; Mihai Cretu

    2006-01-01

    Full text of publication follows: The commercial operation of Unit 1 of Cernavoda NPP started on 2 December, 1996. The unit's reactor type is PHWR-CANDU 6 (electrical capacity 706 MWe), using natural uranium. The nuclear fuel is manufactured in Romania. The Cernavoda nuclear power plant has four CANDU - design steam generators that have been in service since 1996. The paper introduces the new ZR-1 Robot System for Inspection and Maintenance/Repair from Zetec that combines the newest state-of-the-art robotics technology with Zetec experience - based innovation to address the needs for inspection and repair of steam generators. The multipurpose ZR-1 can be easily installed to perform the necessary eddy current inspection and remain installed ready for follow-up maintenance and repair. It has superior technical performances and a modular three axis motion of arm that enables 100% coverage of tube sheet. Automated, repeatable, and precise positioning of tool heads ensures accurate delivery and reducing costly rework and reduces inspection time by 30%. The modular, light weight, and portable design permits easy assembly and disassembly through small openings and it reduces setup/tear down time by 30%. The first deployment of the new ZR-1 Robot was made in September 2004 at the Cernavoda NPP inspection outage. The unit's reactor type is PHWR-CANDU 6 (electrical capacity 706 MWe), using natural uranium; the nuclear fuel is manufactured in Romania. The Cernavoda nuclear power plant Unit 1 has four CANDU - design steam generators that have been in service since 1996. The paper presents also the Zetec's field experience and customer experience with this system. It describes the equipment setup in Cernavoda's steam generators mock-up, functional tests and calibration. Finally, provides details on the execution of the inspection, options for standardizing the inspection techniques and conclusions. (authors)

  11. Risk Importance Determination Process of CANDU Maintenance Rule Function

    International Nuclear Information System (INIS)

    Seo, Mi Ro; Jo, Ha Yan; Hwang, Mi Jeong

    2009-01-01

    In Korea, Maintenance Rule (MR) programs development for all PWR were completed. However, in case of PHWR (CANDU type, Wolsong Unit 1,2,3,4), the study of MR program was delayed, since the design concepts and operating experiences are different from those of PWR. This paper describes the process and results for the risk importance determination process of functions in scope. The risk importance was determined by PSA Basic Event Mapping and Delphi method. For Delphi evaluation, Delphi evaluation item for CANDU need to be developed because the design and normal operation functions are different from PWR

  12. CANDU-BLW-250

    Energy Technology Data Exchange (ETDEWEB)

    Pon, G. A. [Atomic Energy of Canada Ltd, Sheridan Park, ON (Canada)

    1968-04-15

    The plant ''La Centrale nucleaire de Gentiliy'' is located between Montreal and Quebec City on the south shore of the St. Lawrence River. Startup is scheduled for 1971. A CANDU-BLW reactor is the nuclear steam generator. This reactor utilizes a heavy-water moderator, natural uranium oxide fuel, and a boiling light-water coolant. To be economic, this type of plant must have a minimum light-water inventory in the reactor core. A minimum inventory is obtained (a) by reducing the cross-sectional area for coolant flow to a minimum, and (b) by operating at a low coolant density. In CANDU-BLW-250, this is accomplished by operating a closed spaced fuel rod bundle at high steam quality. These features and others in the BLW concept lead to a number of areas of concern and they are summarized below: (i) Heat transfer. It is intended that under normal operating conditions the fuel sheaths will always be wetted with coolant. Some experiments and backup calculations are presented to support this specification. (ii) Hydrodynamic stability. Experiments and analysis indicate that the plant has a considerable over-power capacity before instability is predicted. (iii) Control. This plant does have a positive power coefficient and the transient performance with various disturbances is detailed. (iv) Safety. The positive power coefficient leads to concern over the loss of coolant accident. The results of some accident analyses are presented. (author)

  13. Status of advanced technologies for CANDU reactors

    International Nuclear Information System (INIS)

    Lipsett, J.J.

    1989-01-01

    The future development of the CANDU reactor is a continuation of a successful series of reactors, the most recent of which are nine CANDU 6 Mk 1* units and four Darlington units. There are three projects underway that continue the development of the CANDU reactor. These new design projects flow from the original reactor designs and are a natural progression of the CANDU 6 Mk 1, two units of which are operating successfully in Canada, one each in Argentina and Korea, with five more being built in Rumania. These new design projects are known as: CANDU 6 Mk 2, an improved version of CANDU 6 Mk 1; CANDU 3, a small, advanced version of the CANDU 6 Mk 1; CANDU 6 Mk 3, a series of advanced CANDU reactors. A short description of modified versions of CANDU reactors is given in this paper. 5 figs

  14. The CANDU 6

    International Nuclear Information System (INIS)

    Hopwood, J.M.; Hum, J.

    1999-01-01

    The CANDU 6 is a modem nuclear power plant designed and developed under the aegis of Atomic Energy of Canada, Limited (AECL) for domestic use and for export to other countries. This design has successfully met criteria for operation and redundant safety features required by Canada and by the International Atomic Energy Agency (IAEA) and has an estimable record of performance in all applications to date. Key to this success is a defined program of design enhancement in which changes are made while retaining fundamental features proven by operating experience. Basic design features and progress toward improvements are presented here. (author)

  15. CANDU plant life management - An integrated approach

    International Nuclear Information System (INIS)

    Charlebois, P.; Hart, R.S.; Hopkins, J.R.

    1998-01-01

    Commercial versions of CANDU reactors were put into service starting more than 25 years ago. The first unit of Ontario Hydro's Pickering A station was put into service in 1971, and Bruce A in 1977. Most CANDU reactors, however, are only now approaching their mid-life of 15 to 20 years of operation. In particular, the first series of CANDU 6 plants which entered service in the early 1980's were designed for a 30 year life and are now approaching mid life. The current CANDU 6 design is based on a 40 year life as a result of advancement in design and materials through research and development. In order to assure safe and economic operation of these reactors, a comprehensive CANDU Plant Life Management (PLIM) program is being developed from the knowledge gained during the operation of Ontario Hydro's Pickering, Bruce, and Darlington stations, worldwide information from CANDU 6 stations, CANDU research and development programs, and other national and international sources. This integration began its first phase in 1994, with the identification of most of the critical systems structures and components in these stations, and a preliminary assessment of degradation and mechanisms that could affect their fitness for service for their planned life. Most of these preliminary assessments are now complete, together with the production of the first iteration of Life Management Plans for several of the systems and components. The Generic CANDU 6 PLIM program is now reaching its maturity, with formal processes to systematically identify and evaluate the major CSSCs in the station, and a plan to ensure that the plant surveillance, operation, and maintenance programs monitor and control component degradation well within the original design specifications essential for the plant life attainment. A Technology Watch program is being established to ensure that degradation mechanisms which could impact on plant life are promptly investigated and mitigating programs established. The

  16. CANDU-PHW fuel channel replacement experience

    International Nuclear Information System (INIS)

    Dunn, J.T.; Kakaria, B.K.

    1982-09-01

    One of the main characteristics of the CANDU pressurized heavy water reactor is the use of pressure tubes rather than one large pressure vessel to contain the fuel and coolant. This provides an inherent design capability to permit their replacement in an expeditious manner, without seriously affecting the high capacity factors of the reactor units. Of th eight Ontario Hydro commercial nuclear generating units, the lifetime performance places seven of them (including two that have had some of their fuel channels replaced), in the top ten positions in the world's large nuclear-electric unit performance ranking. Pressure tube cracks in the rolled joint region have resulted in 70 fuel channels being replaced in three reactor units, the latest being at the Bruce Nuclear Generating Station 'A', Unit 2 in February 1982. The rolled joint design and rolling procedures have been modified to eliminate this problem on CANDU units subsequent to Bruce 'A'. This paper describes the CANDU pressure tube performance history and expectations, and the tooling and procedures used to carry out the fuel channel replacement

  17. CANDU fuel performance

    International Nuclear Information System (INIS)

    Ivanoff, N.V.; Bazeley, E.G.; Hastings, I.J.

    1982-01-01

    CANDU fuel has operated successfully in Ontario Hydro's power reactors since 1962. In the 19 years of experience, about 99.9% of all fuel bundles have performed as designed. Most defects occurred before 1979 and subsequent changes in fuel design, fuel management, reactor control, and manufacturing quality control have reduced the current defect rate to near zero. Loss of power production due to defective fuel has been negligible. The outstanding performance continues while maintaining a low unit energy cost for fuel

  18. The evolution of the CANDU energy system - ready for Europe's energy future

    International Nuclear Information System (INIS)

    Hedges, K. R.; Hopwood, J. M.

    2001-01-01

    margins and performance. The CANDU 6 design has evolved in both design and project delivery, so that the current CANDU 6 construction project at Qinshan Phase 3, in China, represents the nuclear project state-of-the-art. Experience with current plants, such as Cernavoda, is an important input to the development of improved designs for the future. Building on the strong CANDU knowledge base, AECL is continuing to adapt the CANDU design to develop the Next Generation CANDU medium-sized fuel channel reactor. This paper discusses the next generation of CANDU designs featuring major improvements in economics, inherent safety characteristics and performance, while retaining the proven benefits of the CANDU family of nuclear power plants. This leads to a seamless evolution which ensures that innovation is introduced in a way which minimizes project or operations uncertainties. (authors)

  19. Advancing the CANDU reactor: From generation to generation

    International Nuclear Information System (INIS)

    Hopwood, Jerry; Duffey, Romney B.; Yu, Steven; Torgerson, Dave F.

    2006-01-01

    Emphasizing safety, reliability and economics, the CANDU reactor development strategy is one of continuous improvement, offering value and assured support to customers worldwide. The Advanced CANDU Reactor (ACR-1000) generation, designed by Atomic Energy of Canada Limited (AECL), meets the new economic expectation for low-cost power generation with high capacity factors. The ACR is designed to meet customer needs for reduced capital cost, shorter construction schedule, high plant capacity factor, low operating cost, increased operating life, simple component replacement, enhanced safety features, and low environmental impact. The ACR-1000 design evolved from the internationally successful medium-sized pressure tube reactor (PTR) CANDU 6 and incorporates operational feedback from eight utilities that operate 31 CANDU units. This technical paper provides a brief description of the main features of the ACR-1000, and its major role in the development path of the generations of the pressure tube reactor concept. The motivation, philosophy and design approach being taken for future generation of CANDU pressure tube reactors are described

  20. Material and fabrication considerations for the CANDU-PHWR heat transport system

    International Nuclear Information System (INIS)

    Filipovic, A.; Price, E.G.; Barber, D.; Nickerson, J.

    1987-03-01

    CANDU PHWR nuclear systems have used carbon steel material for over 25 years. The accumulated operating experience of over 200 reactor years has proven this unique AECL approach to be both technically and economically attractive. This paper discusses design, material and fabrication considerations for out-reactor heat transport system major components. The contribution of this unique choice of materials and equipment to the outstanding CANDU performance is briefly covered

  1. CANDU in the next century

    International Nuclear Information System (INIS)

    Meneley, D.A.; Torgerson, D.F.

    1997-01-01

    AECL's main product line is available today in two designs, designated as CANDU 6 and CANDU 9. Each of these is based on successfully operating pressurized-heavy-water nuclear plants. Several new CANDU stations are under construction or planned around the world. The author presents plant concepts which may evolve from today's products during the 21st century, indicating the particular development directions which might be followed by AECL product development depending on the future competitive environment, economics, and market circumstances. This study shows that the CANDU energy supply system is sufficiently flexible to be adapted into widely varying circumstances over the next century and beyond

  2. Numerical simulator of the CANDU fueling machine driving desk

    International Nuclear Information System (INIS)

    Doca, Cezar

    2008-01-01

    As a national and European premiere, in the 2003 - 2005 period, at the Institute for Nuclear Research Pitesti two CANDU fueling machine heads, no.4 and no.5, for the Nuclear Power Plant Cernavoda - Unit 2 were successfully tested. To perform the tests of these machines, a special CANDU fueling machine testing rig was built and was (and is) available for this goal. The design of the CANDU fueling machine test rig from the Institute for Nuclear Research Pitesti is a replica of the similar equipment operating in CANDU 6 type nuclear power plants. High technical level of the CANDU fueling machine tests required the using of an efficient data acquisition and processing Computer Control System. The challenging goal was to build a computer system (hardware and software) designed and engineered to control the test and calibration process of these fuel handling machines. The design takes care both of the functionality required to correctly control the CANDU fueling machine and of the additional functionality required to assist the testing process. Both the fueling machine testing rig and staff had successfully assessed by the AECL representatives during two missions. At same the time, at the Institute for Nuclear Research Pitesti was/is developed a numerical simulator for the CANDU fueling machine operators training. The paper presents the numerical simulator - a special PC program (software) which simulates the graphics and the functions and the operations at the main desk of the computer control system. The simulator permits 'to drive' a CANDU fueling machine in two manners: manual or automatic. The numerical simulator is dedicated to the training of operators who operate the CANDU fueling machine in a nuclear power plant with CANDU reactor. (author)

  3. Eddy Currents Inspection of CANDU Steam Generator Tubes using Zetec's ZR-1 Robot. Experience in Romania

    Energy Technology Data Exchange (ETDEWEB)

    Scott Hower [Zetec Inc. (Romania); Luiza Vladu; Adrian Nichisov; Mihai Cretu [COMPCONTROL ING. (Romania)

    2006-07-01

    Full text of publication follows: The commercial operation of Unit 1 of Cernavoda NPP started on 2 December, 1996. The unit's reactor type is PHWR-CANDU 6 (electrical capacity 706 MWe), using natural uranium. The nuclear fuel is manufactured in Romania. The Cernavoda nuclear power plant has four CANDU - design steam generators that have been in service since 1996. The paper introduces the new ZR-1 Robot System for Inspection and Maintenance/Repair from Zetec that combines the newest state-of-the-art robotics technology with Zetec experience - based innovation to address the needs for inspection and repair of steam generators. The multipurpose ZR-1 can be easily installed to perform the necessary eddy current inspection and remain installed ready for follow-up maintenance and repair. It has superior technical performances and a modular three axis motion of arm that enables 100% coverage of tube sheet. Automated, repeatable, and precise positioning of tool heads ensures accurate delivery and reducing costly rework and reduces inspection time by 30%. The modular, light weight, and portable design permits easy assembly and disassembly through small openings and it reduces setup/tear down time by 30%. The first deployment of the new ZR-1 Robot was made in September 2004 at the Cernavoda NPP inspection outage. The unit's reactor type is PHWR-CANDU 6 (electrical capacity 706 MWe), using natural uranium; the nuclear fuel is manufactured in Romania. The Cernavoda nuclear power plant Unit 1 has four CANDU - design steam generators that have been in service since 1996. The paper presents also the Zetec's field experience and customer experience with this system. It describes the equipment setup in Cernavoda's steam generators mock-up, functional tests and calibration. Finally, provides details on the execution of the inspection, options for standardizing the inspection techniques and conclusions. (authors)

  4. Localization of CANDU technology

    Energy Technology Data Exchange (ETDEWEB)

    Alizadeh, Ala

    2010-09-15

    The CANDU pressurized heavy water reactor's principal design features suit it particularly well for technology transfer and localization. When the first commercial CANDU reactors of 540 MWe entered service in 1971, Canada's population of less than 24 million supported a 'medium' level of industrial development, lacking the heavy industrial capabilities of larger countries like the USA, Japan and Europe. A key motivation for Canada in developing the CANDU design was to ensure that Canada would have the autonomous capacity to build and operate nuclear power reactors without depending on foreign sources for key components or enriched fuel.

  5. Feedback of operating experience in nuclear power plants

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1995-06-01

    The feedback of operating experience of nuclear facilities to the designers, manufacturers, operators and regulators is one important means of maintaining and improving safety. The Atomic Energy Control Board`s Advisory Committee on Nuclear Safety examined the means for feedback currently being employed, how effective they are and what improvements are advisable. The review found that the need for feedback of operating experience is well recognized within those institutions contributing to the safety of CANDU power reactors, and that the existing procedures are generally effective. Some recommendations, however, are submitted for improvement in the process.

  6. Feedback of operating experience in nuclear power plants

    International Nuclear Information System (INIS)

    1995-06-01

    The feedback of operating experience of nuclear facilities to the designers, manufacturers, operators and regulators is one important means of maintaining and improving safety. The Atomic Energy Control Board's Advisory Committee on Nuclear Safety examined the means for feedback currently being employed, how effective they are and what improvements are advisable. The review found that the need for feedback of operating experience is well recognized within those institutions contributing to the safety of CANDU power reactors, and that the existing procedures are generally effective. Some recommendations, however, are submitted for improvement in the process

  7. CANDU passive shutdown systems

    Energy Technology Data Exchange (ETDEWEB)

    Hart, R S; Olmstead, R A [AECL CANDU, Sheridan Park Research Community, Mississauga, ON (Canada)

    1996-12-01

    CANDU incorporates two diverse, passive shutdown systems, independent of each other and from the reactor regulating system. Both shutdown systems function in the low pressure, low temperature, moderator which surrounds the fuel channels. The shutdown systems are functionally different, physically separate, and passive since the driving force for SDS1 is gravity and the driving force for SDS2 is stored energy. The physics of the reactor core itself ensures a degree of passive safety in that the relatively long prompt neutron generation time inherent in the design of CANDU reactors tend to retard power excursions and reduces the speed required for shutdown action, even for large postulated reactivity increases. All passive systems include a number of active components or initiators. Hence, an important aspect of passive systems is the inclusion of fail safe (activated by active component failure) operation. The mechanisms that achieve the fail safe action should be passive. Consequently the passive performance of the CANDU shutdown systems extends beyond their basic modes of operation to include fail safe operation based on natural phenomenon or stored energy. For example, loss of power to the SDS1 clutches results in the drop of the shutdown rods by gravity, loss of power or instrument air to the injection valves of SDS2 results in valve opening via spring action, and rigorous self checking of logic, data and timing by the shutdown systems computers assures a fail safe reactor trip through the collapse of a fluctuating magnetic field or the discharge of a capacitor. Event statistics from operating CANDU stations indicate a significant decrease in protection system faults that could lead to loss of production and elimination of protection system faults that could lead to loss of protection. This paper provides a comprehensive description of the passive shutdown systems employed by CANDU. (author). 4 figs, 3 tabs.

  8. Data base for a CANDU-PHW operating on a once-through natural uranium cycle

    International Nuclear Information System (INIS)

    1979-07-01

    This report, prepared for INFCE, describes a standard 600 MW(e) CANDU-PHW reactor operating on a once-through natural uranium fuel cycle. Subsequently, data are given for an extrapolated 1000 MW(e) design (the nominal capacity adopted for the INFCE study) operating on the same fuel cycle. (author)

  9. Development of a web-based CANDU core management procedures automation system

    International Nuclear Information System (INIS)

    Lee, S.; Park, D.; Yeom, C.; Suh, H.

    2007-01-01

    Introduce CANDU core management procedures automation system (COMPAS) - A web-based application which semi-automates several CANDU core management tasks. It provides various functionalities including selection and evaluation of refueling channel, detector calibration, coolant flow estimation and thermal power calculation through automated interfacing with analysis codes (RFSP, NUCIRC, etc.) and plant data. It also utilizes brand new .NET computing technology such as ASP.NET, smart client, web services and so on. Since almost all functions are abstracted from the previous experiences of the current working members of the Wolsong Nuclear Power Plant (NPP), it will lead to an efficient and safe operation of CANDU plants. (author)

  10. Development of a web-based CANDU core management procedures automation system

    Energy Technology Data Exchange (ETDEWEB)

    Lee, S.; Park, D.; Yeom, C. [Inst. for Advanced Engineering (IAE), Yongin (Korea, Republic of); Suh, H. [Korea Hydro and Nuclear Power (KHNP), Wolsong (Korea, Republic of)

    2007-07-01

    Introduce CANDU core management procedures automation system (COMPAS) - A web-based application which semi-automates several CANDU core management tasks. It provides various functionalities including selection and evaluation of refueling channel, detector calibration, coolant flow estimation and thermal power calculation through automated interfacing with analysis codes (RFSP, NUCIRC, etc.) and plant data. It also utilizes brand new .NET computing technology such as ASP.NET, smart client, web services and so on. Since almost all functions are abstracted from the previous experiences of the current working members of the Wolsong Nuclear Power Plant (NPP), it will lead to an efficient and safe operation of CANDU plants. (author)

  11. CANDU-BLW-250

    Energy Technology Data Exchange (ETDEWEB)

    Pon, G A

    1967-09-15

    The plant 'La Centrale nucleaire de Gentilly' is located between Montreal and Quebec City on the south shore of the St. Lawrence River and start-up is scheduled for 1971. A CANDU-BLW reactor is the nuclear steam generator. his reactor utilizes a heavy water moderator, natural uranium oxide fuel, and a boiling light water coolant. To be economic, this type of plant must have a minimum light water inventory in the reactor core. A minimum inventory is obtained (a) by reducing the cross-sectional area for coolant flow to a minimum, and (b) by operating at a low-coolant density. In CANDU-BLW-250, this is accomplished by operating a closed spaced fuel rod bundle at high steam quality. These features and others in the BLW concept lead to a number of areas of concern and they are summarized below: (1) Heat Transfer: It is intended that under normal operating conditions the fuel sheaths will always be wetted with coolant. (ii) Hydrodynamic Stability: Experiments and analysis indicate that the plant has a considerable over-power capacity before instability is predicted. (iii) Control: This plant does have a positive power coefficient and the transient performance with various disturbances are detailed. (iv) Safety: The positive power coefficient leads to concern over the loss of coolant accident. The results of some accident analysis are presented. (author)

  12. Achieving CANDU excellence through collaboration

    Energy Technology Data Exchange (ETDEWEB)

    Dermarkar, F. [CANDU Owners Group Inc., Toronto, Ontario (Canada)

    2015-07-01

    All Operators of CANDU/PHWR Worldwide, and AECL, are members of Candu Owners Group (COG). COG has evolved to become primarily an Operators Owners Group with annual turnover of $75M. It is all about value to the members providing a diverse offering of services to meet a broad spectrum of member needs, linking our members together prioritizing and organizing to enable members to access what they need, when they need it. Collaboration benefits both COG and EPRI.

  13. Achieving CANDU excellence through collaboration

    International Nuclear Information System (INIS)

    Dermarkar, F.

    2015-01-01

    All Operators of CANDU/PHWR Worldwide, and AECL, are members of Candu Owners Group (COG). COG has evolved to become primarily an Operators Owners Group with annual turnover of $75M. It is all about value to the members providing a diverse offering of services to meet a broad spectrum of member needs, linking our members together prioritizing and organizing to enable members to access what they need, when they need it. Collaboration benefits both COG and EPRI.

  14. Candu technology: the next generation now

    International Nuclear Information System (INIS)

    Hopwood, J.M.; Duffey, R.B.; Torgerson, D.F.

    2001-01-01

    We describe the development philosophy, direction and concepts that are being utilized by AECL to refine the CANDU reactor to meet the needs of current and future competitive energy markets. The technology development path for CANDU reactors is based on the optimization of the pressure tube concept. Because of the inherent modularity and flexibility of this basis for the core design, it is possible to provide a seamless and continuous evolution of the reactor design and performance. There is no need for a drastic shift in concept, in technology or in fuel. By continual refinement of the flow and materials conditions in the channels, the basic reactor can be thermally and operationally efficient, highly competitive and economic, and highly flexible in application. Thus, the design can build on the successful construction and operating experience of the existing plants, and no step changes in development direction are needed. This approach minimizes investor, operator and development risk but still provides technological, safety and performance advances. In today's world energy markets, major drivers for the technology development are: (a) reduced capital cost; (b) improved operation; (c) enhanced safety; and (d) fuel cycle flexibility. The drivers provide specific numerical targets. Meeting these drivers ensures that the concept meets and exceeds the customer economic, performance, safety and resource use goals and requirements, including the suitable national and international standards. This logical development of the CANDU concept leads naturally to the 'Next Generation' of CANDU reactors. The major features under development include an optimized lattice for SEU (slightly enriched uranium) fuel, light water cooling coupled with heavy water moderation, advanced fuel channels and CANFLEX fuel, optimization of plant performance, enhanced thermal and BOP (balance of plant) efficiency, and the adoption of layout and construction technology adapted from successful on

  15. Load-following performance and assessment of CANDU fuel

    Energy Technology Data Exchange (ETDEWEB)

    Tayal, M.; Floyd, M.; Rattan, D.; Xu, Z.; Manzer, A.; Lau, J. [Atomic Energy of Canada Limited, Mississauga, Ontario (Canada); Kohn, E. [Ontario Power Generation, Fuel and Fuel Channel Analysis Dept., Toronto, Ontario (Canada)

    1999-09-01

    Load following of nuclear reactors is now becoming an economic necessity in some countries. When nuclear power stations are operated in a load-following mode, the reactor and the fuel may be subjected to step changes in power on a weekly, daily, or even hourly basis, depending on the grid's needs. This paper updates the previous surveys of load-following capability of CANDU fuel, focusing mainly on the successful experience at the Bruce B station. As well, initial analytical assessments are provided that illustrate the capability of CANDU fuel to survive conditions other than those for which direct in-reactor evidence is available. (author)

  16. CANDU reactor - supporting the nuclear renaissance

    International Nuclear Information System (INIS)

    Oberth, R.

    2010-01-01

    'Full text:' The CANDU reactor has proven to be a strong performer in both the Canada, with 22 units constructed in Ontario, New Brunswick and Quebec, as well as in Argentina, Korea, Romania and China where a further nine units are operating and two in the planning stage. The average lifetime capacity factor of the CANDU reactor fleet is 89%. The last seven CANDU projects in Korea, China, and Romania have been completed on budget and on schedule. CANDU reactors have the highest uranium utilization efficiency measures as electricity output per ton of uranium mined. The CANDU fuel channel design using on-power fuelling and a heavy water moderator enables flexible fueling options - from the current natural uranium option to burning uranium recovered from used LWR reactor fuel and even a thorium-based fuel. AECL and the CANDU reactor are poised to participate in the worldwide construction at least 250 new reactors over the next 20 years. (author)

  17. Plutonium dispositioning in CANDU

    International Nuclear Information System (INIS)

    Boczar, P.G.; Feinroth, H.; Luxat, J.C.

    1995-07-01

    Recently, the U.S. Department of Energy (DOE) sponsored Atomic Energy of Canada Limited (AECL) to evaluate salient technical, strategic, schedule, and cost-related parameters of using CANDU reactors for dispositioning of weapons-grade plutonium in the form of Mixed OXide (MOX) fuel. A study team, consisting of key staff from the CANDU reactor designers and researchers (AECL), operators (Ontario Hydro) and fuel suppliers, analyzed all significant factors involved in such application, with the objective of identifying an arrangement that would permit the burning of MOX in CANDU at the earliest date. One of Ontario Hydro's multi-unit stations, Bruce A nuclear generating station (4x769 MW(e)), was chosen as the reference for the study. The assessment showed that no significant modifications of reactor or process systems are necessary to operate with a full MOX core. Plant modifications would be limited to fuel handling and modifications necessary to accommodate enhanced security and safeguards requirements. No safety limitations were identified

  18. Data base for a CANDU-PHW operating on a once-through, natural uranium fuel cycle

    International Nuclear Information System (INIS)

    1979-07-01

    This report, prepared for INFCE, describes a standard 600 MW(e) CANDU-PHW reactor operating on a once-through natural uranium fuel cycle. Subsequently, data are given for an extrapolated 1000 MW(e) design (the nominal capacity adopted for the INFCE study) operating on the same fuel cycle. (author)

  19. CANDU fuel

    International Nuclear Information System (INIS)

    MacEwan, J.R.; Notley, M.J.F.; Wood, J.C.; Gacesa, M.

    1982-09-01

    The direction of CANDU fuel development was set in 1957 with the decision to build pressure tube reactors. Short - 50 cm long - rodded bundles of natural UO 2 clad in Zircaloy were adopted to facilitate on-power fuelling to improve uranium utilization. Progressive improvements were made during 25 years of development, involving 650 man years and 180 million dollars. Today's CANDU bundle is based on the knowledge gained from extensive irradiation testing and experience in power reactors. The main thrust of future development is to demonstrate that the present bundle is suitable, with minor modifications, for thorium fuels

  20. CANDU 9 fuelling machine carriage

    Energy Technology Data Exchange (ETDEWEB)

    Ullrich, D J; Slavik, J F [Atomic Energy of Canada Ltd., Saskatoon, SK (Canada)

    1997-12-31

    Continuous, on-power refuelling is a key feature of all CANDU reactor designs and is essential to maintaining high station capacity factors. The concept of a fuelling machine carriage can be traced to the early CANDU designs, such as the Douglas Point Nuclear Generating Station. In the CANDU 9 480NU unit, the combination of a mobile carriage and a proven fuelling machine head design comprises an effective means of transporting fuel between the reactor and the fuel transfer ports. It is a suitable alternative to the fuelling machine bridge system that has been utilized in the CANDU 6 reactor units. The CANDU 9 480NU fuel handling system successfully combines features that meet the project requirements with respect to fuelling performance, functionality, seismic qualification and the use of proven components. The design incorporates improvements based on experience and applicable current technologies. (author). 4 figs.

  1. CANDU 9 fuelling machine carriage

    International Nuclear Information System (INIS)

    Ullrich, D.J.; Slavik, J.F.

    1996-01-01

    Continuous, on-power refuelling is a key feature of all CANDU reactor designs and is essential to maintaining high station capacity factors. The concept of a fuelling machine carriage can be traced to the early CANDU designs, such as the Douglas Point Nuclear Generating Station. In the CANDU 9 480NU unit, the combination of a mobile carriage and a proven fuelling machine head design comprises an effective means of transporting fuel between the reactor and the fuel transfer ports. It is a suitable alternative to the fuelling machine bridge system that has been utilized in the CANDU 6 reactor units. The CANDU 9 480NU fuel handling system successfully combines features that meet the project requirements with respect to fuelling performance, functionality, seismic qualification and the use of proven components. The design incorporates improvements based on experience and applicable current technologies. (author). 4 figs

  2. Cernavoda CANDU severe accident evaluation

    International Nuclear Information System (INIS)

    Negut, G.; Marin, A.

    1997-01-01

    The papers present the activities dedicated to Romania Cernavoda Nuclear Power Plant first CANDU Unit severe accident evaluation. This activity is part of more general PSA assessment activities. CANDU specific safety features are calandria moderator and calandria vault water capabilities to remove the residual heat in the case of severe accidents, when the conventional heat sinks are no more available. Severe accidents evaluation, that is a deterministic thermal hydraulic analysis, assesses the accidents progression and gives the milestones when important events take place. This kind of assessment is important to evaluate to recovery time for the reactor operators that can lead to the accident mitigation. The Cernavoda CANDU unit is modeled for the of all heat sinks accident and results compared with the AECL CANDU 600 assessment. (orig.)

  3. Experiments in ZED-2 to study the physics of low-void reactivity fuel in CANDU

    International Nuclear Information System (INIS)

    Zeller, M.B.; Celli, A.; McPhee, G.P.

    1994-01-01

    Prospective CANDU clients have indicated a desire for a zero or negative coolant void reactivity. In response to this market requirement AECL Research and AECL CANDU are jointly developing and testing a Low-Void Reactivity Fuel (LVRF) bundle, which will be retrofitable to the current generation of CANDU reactors. An important component of the LVRF program is the undertaking of reactor-physics experiments in the zero-energy ZED-2 lattice test facility at Chalk River Laboratories. Preliminary void-reactivity measurements have already been performed in ZED-2 using a limited amount of the prototype fuel. These experiments were to provide a proof-of-principle for the LVRF concept. A more comprehensive set of experiments are planned for later this year. Experiments to be performed include: measuring the critical buckling of CANDU-type lattices containing LVRF, with and without coolant in the channels; measuring the reactivity effect of heating the LVRF fuel and coolant in ZED-2 hot channels; and measuring detailed reaction rates and neutron density distributions across a LVRF bundle, in voided and D 2 O-cooled channels, by the foil activation method. This paper describes the experimental approach to be used for the study and presents calculations employing transport and diffusion theory to predict the results. The codes used for the simulations are the lattice code WIMS-AECL and the core code CONIFERS. Included in the paper are results from the preliminary measurement of void coefficient for LVRF in a ZED-2 lattice and a comparison of those results to predictions based on WIMS-AECL calculations. (author). 3 refs., 1 tab., 10 figs

  4. Leak-before-break experience in CANDU reactors

    International Nuclear Information System (INIS)

    Price, E.G.; Moan, G.D.; Coleman, C.E.

    1988-01-01

    In the Canada deuterium uranium (CANDU) reactor, each of the ∼ 400 hot pressure tubes containing the fuel bundles and the pressurized heat transport water is surrounded and insulated from the cold moderator by a calandria tube. The pressure tubes are made from cold-worked Zr-2.5 Nb with a minimum wall thickness of 4.19 mm, and the calandria tubes are made from annealed Zircaloy-2 with a minimum wall thickness of 1.37 mm. The annulus between these two tubes contains an inert gas. Leak-before-break has developed into an operational tool in CANDU reactors to prevent unstable failure of pressure tubes. A procedure for leak detection and reactor response has been developed from the use of the annulus gas, whose dew point is measured to ascertain if leaks have crept into the annulus. The characteristics of the crack are used to establish the response time for leak detection. The reactor is required to be shut down before the length of the slowly growing crack has reached the critical stage. This critical crack length, determined using slit burst tests on tubes, is the crack length at which the crack growth becomes unstable. The most likely crack growth mechanism is delayed hydride cracking. This mechanism requires three conditions to occur simultaneously: the material must be sensitive to delayed hydride cracking; zirconium hydrides must be present in the material; and the tensile stress must be sufficiently great

  5. Systems analysis of the CANDU 3 Reactor

    Energy Technology Data Exchange (ETDEWEB)

    Wolfgong, J.R.; Linn, M.A.; Wright, A.L.; Olszewski, M.; Fontana, M.H. [Oak Ridge National Lab., TN (United States)

    1993-07-01

    This report presents the results of a systems failure analysis study of the CANDU 3 reactor design; the study was performed for the US Nuclear Regulatory Commission. As part of the study a review of the CANDU 3 design documentation was performed, a plant assessment methodology was developed, representative plant initiating events were identified for detailed analysis, and a plant assessment was performed. The results of the plant assessment included classification of the CANDU 3 event sequences that were analyzed, determination of CANDU 3 systems that are ``significant to safety,`` and identification of key operator actions for the analyzed events.

  6. Detection of gaseous heavy water leakage points in CANDU 6 pressurized heavy water reactors

    International Nuclear Information System (INIS)

    Park, T-K.; Jung, S-H.

    1996-01-01

    During reactor operation, the heavy water filled primary coolant system in a CANDU 6 Pressurized Heavy Water (PHWR) may leak through routine operations of the plant via components, mechanical joints, and during inadvertent operations etc. Early detection of leak points is therefore important to maintain plant safety and economy. There are many independent systems to monitor and recover heavy water leakage in a CANDU 6 PHWR. Methodology for early detection based on operating experience from these systems, is investigated in this paper. In addition, the four symptoms of D 2 O leakage, the associated process for clarifying and verifying the leakage, and the probable points of leakage are discussed. (author)

  7. CANDU reg-sign -- A Canadian energy system

    International Nuclear Information System (INIS)

    Sejnoha, R.

    1994-01-01

    Uranium is one of Canada's important natural resources. It is perhaps not surprising that a country with such an abundance of uranium developed its own inexpensive, safe, and environmentally friendly system of energy generation, based on uranium: CANDU reg-sign (CANada-Deuterium-Uranium, a registered trademark of AECL). The objective of this paper is to describe briefly the main features of the CANDU system and explain methods used to assure the compatibility with the requirements for a clean and safe environment. The paper describes the CANDU reactor, and discusses storage of spent fuel, reactor performance, normal operating conditions, safety under accident conditions, and quality assurance in design, manufacturing, and operation

  8. CANDU combined cycles featuring gas-turbine engines

    International Nuclear Information System (INIS)

    Vecchiarelli, J.; Choy, E.; Peryoga, Y.; Aryono, N.A.

    1998-01-01

    In the present study, a power-plant analysis is conducted to evaluate the thermodynamic merit of various CANDU combined cycles in which continuously operating gas-turbine engines are employed as a source of class IV power restoration. It is proposed to utilize gas turbines in future CANDU power plants, for sites (such as Indonesia) where natural gas or other combustible fuels are abundant. The primary objective is to eliminate the standby diesel-generators (which serve as a backup supply of class III power) since they are nonproductive and expensive. In the proposed concept, the gas turbines would: (1) normally operate on a continuous basis and (2) serve as a reliable backup supply of class IV power (the Gentilly-2 nuclear power plant uses standby gas turbines for this purpose). The backup class IV power enables the plant to operate in poison-prevent mode until normal class IV power is restored. This feature is particularly beneficial to countries with relatively small and less stable grids. Thermodynamically, the advantage of the proposed concept is twofold. Firstly, the operation of the gas-turbine engines would directly increase the net (electrical) power output and the overall thermal efficiency of a CANDU power plant. Secondly, the hot exhaust gases from the gas turbines could be employed to heat water in the CANDU Balance Of Plant (BOP) and therefore improve the thermodynamic performance of the BOP. This may be accomplished via several different combined-cycle configurations, with no impact on the current CANDU Nuclear Steam Supply System (NSSS) full-power operating conditions when each gas turbine is at maximum power. For instance, the hot exhaust gases may be employed for feedwater preheating and steam reheating and/or superheating; heat exchange could be accomplished in a heat recovery steam generator, as in conventional gas-turbine combined-cycle plants. The commercially available GateCycle power plant analysis program was applied to conduct a

  9. Trends in CANDU licensing

    International Nuclear Information System (INIS)

    Snell, V.G.; Grant, S.D.

    1997-01-01

    Modern utilities view nuclear power more and more as a commodity - it must compete 'today' with current alternatives to attract their investment. With its long construction times and large capital investment, nuclear plants are vulnerable to delays once they have been committed. There are two related issues. Where the purchaser and the regulator are experienced in CANDU, the thrust is a very practical one: to identify and resolve major licensing risks at a very early stage in the project. Thus for a Canadian project, the designer (AECL) and the prospective purchaser would deal directly with the AECB. However CANDU has also been successfully licensed in other countries, including Korea, Romania, Argentina, India and Pakistan. Each of these countries has its own regulatory agency responsible for licensing the plant. In addition, however, the foreign customer and regulator may seek input from the AECB, up to and including a statement of licensability in Canada; this is not normally needed for a ''repeat'' plant and/or if the customer is experienced in CANDU, but can be requested if the plant configuration has been modified significantly from an already-operating CANDU. It is thus the responsibility of the designer to initiate early discussions with the AECB so the foreign CANDU meets the expectations of its customers

  10. CANDU 9 nuclear power plant simulator

    International Nuclear Information System (INIS)

    Kattan, M.; MacBeth, M.J.; Lam, K.

    1995-01-01

    Simulators are playing, an important role in the design and operations of CANDU reactors. They are used to analyze operating procedures under standard and upset conditions. The CANDU 9 nuclear power plant simulator is a low fidelity, near full scope capability simulator. It is designed to play an integral part in the design and verification of the control centre mock-up located in the AECL design office. It will also provide CANDU plant process dynamic data to the plant display system (PDS), distributed control system (DCS) and to the mock-up panel devices. The simulator model employs dynamic mathematical models of the various process and control components that make up a nuclear power plant. It provides the flexibility to add, remove or update user supplied component models. A block oriented process input is provided with the simulator. Individual blocks which represent independent algorithms of the model are linked together to generate the required overall plant model. As a design tool the simulator will be used for control strategy development, human factors studies (information access, readability, graphical display design, operability), analysis of overall plant control performance, tuning estimates for major control loops and commissioning strategy development. As a design evaluation tool, the simulator will be used to perform routine and non-routine procedures, practice 'what if' scenarios for operational strategy development, practice malfunction recovery procedures and verify human factors activities. This paper will describe the CANDU 9 plant simulator and demonstrate its implementation and proposed utility as a tool in the control system and control centre design of a CANDU 9 nuclear power plant. (author). 2 figs

  11. A framework for operator support systems for CANDU

    International Nuclear Information System (INIS)

    Lupton, L.R.; Lipsett, J.J.; Shah, R.R.

    1989-11-01

    The size and complexity of nuclear power plants has increased significantly in the last 20 years. There is a general agreement that both plant safety and availability can be enhanced by providing the operator with more operational support if than can be done without overloading him/her with unnecessary information. Recent advances in computer technology provide opportunities for implementing operator support systems that are significantly different from the ones based on the more conventional technologies used in plant control rooms. In particular, artificial intelligence and the related technologies will play a major role in the development of innovative methods for information processing and presentation. Our approach to these technologies is that they must be integrated into the overall management and control philosophy of the plant and are not to be treated as vehicles to implement point solutions. The underlying philosophy behind this approach and the design objectives and goals for the CANDU 3 control centre are discussed in this paper. Operator support systems will integrate into the overall control philosophy by complementing the operator. There is also a role for such systems in assisting the operator to be a situation manager, organizing, managing and planning the running of the plant. Four support systems that incorporate the underlying philosophy are described

  12. A framework for operator support systems for CANDU

    International Nuclear Information System (INIS)

    Lupton, L.R.; Lipsett, J.J.; Shah, R.R.

    1990-01-01

    The size and complexity of nuclear power plants has increased significantly in the last 20 years. There is a general agreement that both plant safety and availability can be enhanced by providing the operator with more operational support if that can be cone without overloading him/her with unnecessary information. Recent advances in computer technology provide opportunities for implementing operator support systems that are significantly different from the ones based on the more conventional technologies used in plant control rooms. In particular, artificial intelligence (AI) and the related technologies will play a major role in the development of innovative methods for information processing and presentation. Our approach to these technologies is that they must be integrated into the overall management and control philosophy of the plant and are not to be treated as vehicles to implement point solutions. The underlying philosophy behind this approach and the design objectives and goals for the CANDU 3 control centre are discussed in this paper. Operator support systems will integrate into the overall controll philosophy by complementing the operator. There is also a role for such systems in assisting the operator be a 'situation manager' organizing, managing and planning the running of the plant. Four support systems that invorporate the underlying philosophy are described

  13. Basic research and industrialization of CANDU advanced fuel

    Energy Technology Data Exchange (ETDEWEB)

    Chun, Suk Ho; Park, Joo Hwan; Jun, Ji Su [and others

    2000-04-01

    Wolsong Unit 1 as the first heavy water reactor in Korea has been in service for 17 years since 1983. It would be about the time to prepare a plan for the solution of problems due to aging of the reactor. The aging of CANDU reactor could lead especially to the steam generator cruding and pressure tube sagging and creep and then decreases the operation margin to make some problems on reactor operations and safety. The counterplan could be made in two ways. One is to repair or modify reactor itself. The other is to develop new advanced fuel to increase of CANDU operation margin effectively, so as to compensate the reduced operation margin. Therefore, the first objectives in the present R and D is to develop the CANFLEX-NU (CANDU Flexible fuelling-Natural Uranium) fuel as a CANDU advanced fuel. The second objectives is to develop CANDU advanced fuel bundle to utilize advanced fuel cycles such as recovered uranium, slightly enriched uranium, etc. and so to raise adaptability for change in situation of uranium market. Also, it is to develop CANDU advanced fuel technology which improve uranium utilization to cope with a world-wide imbalance between uranium supply and demand, without significant modification of nuclear reactor design and refuelling strategies. As the implementations to achieve the above R and D goal, the work contents and scope of technology development of CANDU advanced fuel using natural uranium (CANFLEX-NU) are the fuel element/bundle designs, the nuclear design and fuel management analysis, the thermalhydraulic analysis, the safety analysis, fuel fabrication technologies, the out-pile thermalhydraulic test and in-pile irradiation tests performed. At the next, the work scopes and contents of feasibility study of CANDU advanced fuel using recycled uranium (CANFLEX-RU) are the fuel element/bundle designs, the reactor physics analysis, the thermalhydraulic analysis, the basic safety analysis of a CANDU-6 reactor with CANFLEX-RU fuel, the fabrication and

  14. Basic research and industrialization of CANDU advanced fuel

    International Nuclear Information System (INIS)

    Chun, Suk Ho; Park, Joo Hwan; Jun, Ji Su

    2000-04-01

    Wolsong Unit 1 as the first heavy water reactor in Korea has been in service for 17 years since 1983. It would be about the time to prepare a plan for the solution of problems due to aging of the reactor. The aging of CANDU reactor could lead especially to the steam generator cruding and pressure tube sagging and creep and then decreases the operation margin to make some problems on reactor operations and safety. The counterplan could be made in two ways. One is to repair or modify reactor itself. The other is to develop new advanced fuel to increase of CANDU operation margin effectively, so as to compensate the reduced operation margin. Therefore, the first objectives in the present R and D is to develop the CANFLEX-NU (CANDU Flexible fuelling-Natural Uranium) fuel as a CANDU advanced fuel. The second objectives is to develop CANDU advanced fuel bundle to utilize advanced fuel cycles such as recovered uranium, slightly enriched uranium, etc. and so to raise adaptability for change in situation of uranium market. Also, it is to develop CANDU advanced fuel technology which improve uranium utilization to cope with a world-wide imbalance between uranium supply and demand, without significant modification of nuclear reactor design and refuelling strategies. As the implementations to achieve the above R and D goal, the work contents and scope of technology development of CANDU advanced fuel using natural uranium (CANFLEX-NU) are the fuel element/bundle designs, the nuclear design and fuel management analysis, the thermalhydraulic analysis, the safety analysis, fuel fabrication technologies, the out-pile thermalhydraulic test and in-pile irradiation tests performed. At the next, the work scopes and contents of feasibility study of CANDU advanced fuel using recycled uranium (CANFLEX-RU) are the fuel element/bundle designs, the reactor physics analysis, the thermalhydraulic analysis, the basic safety analysis of a CANDU-6 reactor with CANFLEX-RU fuel, the fabrication and

  15. SEBIM pilot operated valves - CANDU and other applications

    International Nuclear Information System (INIS)

    Schaumburg, Gerald; Hera, Vlad

    1999-01-01

    The SEBIM Group, located at Chateauneuf-les-Martigues, near Marseilles, on the Mediterranean coast of France, is a market leader for the pilot operated safety relief valves in the nuclear industry. Its valves, which are subject to rigorous safety and reliability criteria, are intended to satisfy the most exigent requirements of not only the nuclear but also other demanding applications. The group manufacturing units are equipped with the state-of-the-art machinery, technical equipment and computer facilities. All personnel is highly specialized and trained. Among many applications the valves designed and manufactured by SEBIM for the biggest CANDU reactors in Canada were subjected to exceptionally difficult testing conditions, prior of being excepted by Ontario Hydro and passed all tests successfully. As a consequence Darlington N.G.S. was equipped with one of the most advanced SEBIM pressure protection piece of equipment, the Tandem Pilot Operated Pressure Relief Valve. Due to the demonstrated qualities of our product we were able to obtain the necessary registration of our valve original design with the appropriate Canadian authorities, both at the provincial level and at the federal level. One may find SEBIM protection and other type of equipment in civilian nuclear plants all over Europe as well as in military applications, like the French Navy. The SEBIM valves, covering a range between 15 mm and 160 mm diameter and capable of withstanding an inlet pressure from 2 MPa to 20 MPa and the temperature of the fluid up to 450 dec. C, are very strong competitors in the specialized field. Among these valves the tandems have special design and special qualities, for special applications. As mentioned above, two of these tandems are used, in parallel, on the Bleed Condenser vessels of the Darlington units to provide the ultimate protection of the Pressure and Inventory Control System and, through it, to the Main Heat Transfer System which is the primary cooling source

  16. Designing for human performance - CANDU electrical panels - then and now

    International Nuclear Information System (INIS)

    Patterson, B.K.

    2003-01-01

    Experience has shown that few changes are made to CANDU control center panels once plants are in service. There are several reasons for this, for example, operational conservatism, outage minimization, avoidance of retraining effort, and perhaps lack of appreciation of improvement opportunities. Since the initial CANDU 6 plants were designed, the industry has moved forward with adoption of new approaches to control room interface design that have introduced changes in design principles and emphasis. At Point Lepreau, the electrical panels have remained virtually unchanged since initial design. The author, the original electrical system commissioning engineer, reviews the design considerations that led to the initial panel design, reviews some of the operational limitations discovered during use, and offers some suggestions on improvement directions, if these panels were being designed today, that would offer an implementation to better support operator tasks. (author)

  17. Validation of WIMS-CANDU using Pin-Cell Lattices

    International Nuclear Information System (INIS)

    Kim, Won Young; Min, Byung Joo; Park, Joo Hwan

    2006-01-01

    The WIMS-CANDU is a lattice code which has a depletion capability for the analysis of reactor physics problems related to a design and safety. The WIMS-CANDU code has been developed from the WIMSD5B, a version of the WIMS code released from the OECD/NEA data bank in 1998. The lattice code POWDERPUFS-V (PPV) has been used for the physics design and analysis of a natural uranium fuel for the CANDU reactor. However since the application of PPV is limited to a fresh fuel due to its empirical correlations, the WIMS-AECL code has been developed by AECL to substitute the PPV. Also, the WIMS-CANDU code is being developed to perform the physics analysis of the present operating CANDU reactors as a replacement of PPV. As one of the developing work of WIMS-CANDU, the U 238 absorption cross-section in the nuclear data library of WIMS-CANDU was updated and WIMS-CANDU was validated using the benchmark problems for pin-cell lattices such as TRX-1, TRX-2, Bapl-1, Bapl-2 and Bapl-3. The results by the WIMS-CANDU and the WIMS-AECL were compared with the experimental data

  18. Study on advanced nuclear fuel cycle of PWR/CANDU synergism

    International Nuclear Information System (INIS)

    Xie Zhongsheng; Huo Xiaodong

    2002-01-01

    According to the concrete condition that China has both PWR and CANDU reactors, one of the advanced nuclear fuel cycle strategy of PWR/CANDU synergism ws proposed, i.e. the reprocessed uranium of spent PWR fuel was used in CANDU reactor, which will save the uranium resource, increase the energy output, decrease the quantity of spent fuels to be disposed and lower the cost of nuclear power. Because of the inherent flexibility of nuclear fuel cycle in CANDU reactor, the transition from the natural uranium to the recycled uranium (RU) can be completed without any changes of the structure of reactor core and operation mode. Furthermore, because of the low radiation level of RU, which is acceptable for CANDU reactor fuel fabrication, the present product line of fuel elements of CANDU reactor only need to be shielded slightly, also the conditions of transportation, operation and fuel management need not to be changed. Thus this strategy has significant practical and economical benefit

  19. Non-electrical CANDU applications

    International Nuclear Information System (INIS)

    Hopwood, Jerry; Kuran, Sermet; Zhou, Xi; Ivanco, Michael; Rolfe, Brian; Mancuso, Connie; Duffey, Romney

    2005-01-01

    AECL has performed studies to utilize CANDU nuclear energy in areas other than electrical generation. The studies presented in this paper include using CANDU for applications in non-traditional areas which expand the use of zero-greenhouse gas energy source. The Oil sands industry demands significant energy input and the majority of the energy required for bitumen extraction is steam and hot water. As the primary production of a CANDU plant is steam, it can satisfy the steam and hot water requirement without a major modification to the Nuclear Steam Plant (NSP). Reverse Osmosis (RO) has been identified by the IAEA as the most promising method for nuclear desalination. Since the RO desalination efficiency increases as its feedwater temperature rises, using condenser cooling water from a CANDU plant as the feedwater for a RO plant and sharing other facilities between these two plants results in significant benefits in capital and operating costs of a desalination plant. Electrolysis powered by nuclear-generated electricity is the technology currently available to produce hydrogen without greenhouse gas emissions. By using the cheaper electricity available at off-peak periods in an open electricity market, this technology could be economically competitive, improve overall energy system efficiency and reduce overall energy system carbon intensity. The paper summarizes the background, technical approaches, feasibility considerations, along with economic comparisons between CANDU nuclear energy and the traditional energy sources for each study. The results show that the CANDU technology is a promising energy source for various industries. (author)

  20. Proceedings of the international conference on CANDU fuel

    International Nuclear Information System (INIS)

    Hastings, I.J.

    1986-01-01

    These proceedings contain full texts of all paper presented at the first International Conference on CANDU Fuel. The Conference was organized and hosted by the Chalk River Branch of the Canadian Nuclear Society and utilized Atomic Energy of Canada Limited's facilities at Chalk River Nuclear Laboratories. Previously, informal Fuel Information Meetings were used in Canada to allow the exchange of information and technology associated with CANDU. The Chalk River conference was the first open international forum devoted solely to CANDU and included representatives of overseas countries with current or potential CANDU programs, as well as Canadian participants. The keynote presentation was given by Dr. J.B. Slater, who noted the correlation between past successes in CANDU fuel cycle technology and the co-operation between researchers, fabricators and reactor owner/operators in all phases of the fuel cycle, and outlined the challenges facing the industry today. In the banquet address, Dr. R.E. Green described the newly restructured AECL Research Company and its mission which blends traditional R and D with commercial initiatives. Since this forum for fuel technology has proven to be valuable, a second International CANDU Fuel Conference is planned for the fall of 1989, again sponsored by the Canadian Nuclear Society

  1. CANDU fuel cycle options in Korea

    International Nuclear Information System (INIS)

    Boczar, P.G.; Fehrenbach, P.J.; Meneley, D.A.

    1996-04-01

    The easiest first step in CANDU fuel-cycle evolution may be the use of slightly enriched uranium (SEU), including recovered uranium from reprocessed LWR spent fuel. Relatively low enrichment (up to 1.2%) will result in a twoto three-fold reduction in the quantity of spent fuel per unit energy production, reductions in fuel-cycle costs, and greater flexibility in the design of new reactors. The CANFLEX (CANDU FLEXible) fuel bundle would be the optimal fuel carrier. A country that has both CANDU and PWR reactors can exploit the natural synergism between these two reactor types to minimize overall waste production, and maximize energy derived from the fuel. This synergism can be exploited through several different fuel cycles. A high burnup CANDU MOX fuel design could be used to utilize plutonium from conventional reprocessing or more advanced reprocessing options (such as co-processing). DUPIC (Direct Use of Spent PWR Fuel In CANDU) represents a recycle option that has a higher degree of proliferation resistance than does conventional reprocessing, since it uses only dry processes for converting spent PWR fuel into CANDU fuel, without separating the plutonium. Good progress is being made in the current KAERI, AECL, and U.S. Department of State program in demonstrating the technical feasibility of DUPIC. In the longer term, CANDU reactors offer even more dramatic synergistic fuel cycles with PWR or FBR reactors. If the objective of a national fuel-cycle program is the minimization of actinide waste or destruction of long-lived fission products, then studies have shown the superiority of CANDU reactors in meeting this objective. Long-term energy security can be assured either through the thorium cycle or through a CANDU 1 FBR system, in which the FBR would be operated as a 'fuel factory,' providing the fissile material to power a number of lower-cost, high efficiency CANDU reactors. In summary, the CANDU reactor's simple fuel design, high neutron economy, and on

  2. A study on performance of adjuster rod system and banking scheme in operational transient of CANDU-6 RUFIC core

    International Nuclear Information System (INIS)

    Kim, Soon Young; Suk, Ho Chun

    2002-01-01

    The performance of adjuster rod system in four operational transients of CANDU-6 RUFIC (Recovered Uranium Fuel In CANDU) core was preliminarily assessed, where the operational transients include startup after a short shutdown, startup after a poison-out shutdown, shim mode operation, and a stepback to 60% full power. The results of the preliminary assessment indicated that the adjuster rod system as currently designed and installed in the CANDU-6 NU (Natural Uranium) core will adequately meet the functional requirements in the RUFIC core. Comparing to the performance of adjuster rod system in the NU core, the total worth of the adjuster system in the RUFIC core is reduced, leading to less xenon override capability and shimming capability. In spite of the reduction of total worth, however, the overall performance of adjuster rod system in the operation transient of the RUFIC core is expected to still be satisfied. An alternative adjuster-banking scheme is also included in the assessment. The alternative adjuster-banking scheme involves rods in Bank 1 and Bank 7 being re-distributed within the two banks. The overall results from the transients studied indicated that the alternative banking scheme does show some better performance characteristics and merits

  3. Thermal analysis model for the temperature distribution of the CANDU spent fuel assembly

    International Nuclear Information System (INIS)

    Choi, Hae Yun; Kwon, Jong Soo; Park, Seong Hoon; Kim, Seong Rea; Lee, Gi Won

    1996-01-01

    The purpose of this technical is to introduce the methodology and experimental process for the experimental research work with the mock-up test performed to verify and validate the MAXROT code which is a thermal analysis method for Wolsong (CANDU) spent fuel dry storage canister. The experiment was conducted simulating the heat transfer characteristics of combinations of equilateral triangular and square pitch arrays of heater rods, similar to a CANDU spent fuel bundle. After assembly of the heater rod bundle into the containment vessel, the experimental apparatus was operated under the same operating and boundary conditions as an interim dry storage condition at the nuclear power plant site. The reduced data from this experiment has been utilized to verity a model developed to predict the maximum fuel rod surface temperature in a fuel bundle. These test procedures and the experiment can be utilized to establish the fine thermal analysis method applicable to dry storage system for the spent fuel. 12 figs., 5 tabs., 36 refs. (Author) .new

  4. Thermal analysis model for the temperature distribution of the CANDU spent fuel assembly

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Hae Yun; Kwon, Jong Soo; Park, Seong Hoon; Kim, Seong Rea; Lee, Gi Won [Korea Atomic Energy Research Institute, Taejon (Korea, Republic of)

    1996-01-01

    The purpose of this technical is to introduce the methodology and experimental process for the experimental research work with the mock-up test performed to verify and validate the MAXROT code which is a thermal analysis method for Wolsong (CANDU) spent fuel dry storage canister. The experiment was conducted simulating the heat transfer characteristics of combinations of equilateral triangular and square pitch arrays of heater rods, similar to a CANDU spent fuel bundle. After assembly of the heater rod bundle into the containment vessel, the experimental apparatus was operated under the same operating and boundary conditions as an interim dry storage condition at the nuclear power plant site. The reduced data from this experiment has been utilized to verity a model developed to predict the maximum fuel rod surface temperature in a fuel bundle. These test procedures and the experiment can be utilized to establish the fine thermal analysis method applicable to dry storage system for the spent fuel. 12 figs., 5 tabs., 36 refs. (Author) .new.

  5. Operating performance of CANDU pressure tubes

    International Nuclear Information System (INIS)

    Cheadle, B.A.; Price, E.G.

    1989-04-01

    The performance of Zircaloy-2 and Zr-2.5 Nb pressure tubes in CANDU reactors is reviewed. The accelerated hydriding of Zircaloy-2 in reducing water chemistries can lower the toughness of this material and it is essential that defect-initiating phenomena, such as hydride blister formation from pressure tube to calandria tube contact, be prevented. Zr-2.5 Nb pressure tubes are performing well with low rates of hydrogen pick-up and good retention of material properties

  6. Conceptual designs for very high-temperature CANDU reactors

    Energy Technology Data Exchange (ETDEWEB)

    Bushby, S.J.; Dimmick, G.R.; Duffey, R.B. [Atomic Energy of Canada Ltd., Chalk River, Ontario (Canada)

    2000-07-01

    Although its environmental benefits are demonstrable, nuclear power must be economically competitive with other energy sources to ensure it retains, or increases, its share of the changing and emerging energy markets of the next decades. In recognition of this, AECL is studying advanced reactor concepts with the goal of significant reductions in capital cost through increased thermodynamic efficiency and plant simplification. The program, generically called CANDU-X, examines concepts for the future, but builds on the success of the current CANDU designs by keeping the same fundamental design characteristics: excellent neutron economy for maximum flexibility in fuel cycle; an efficient heavy-water moderator that provides a passive heat sink under upset conditions; and, horizontal fuel channels that enable on-line refueling for optimum fuel utilization and power profiles. Retaining the same design fundamentals takes maximum advantage of the existing experience base, and allows technological and design improvements developed for CANDU-X to be incorporated into more evolutionary CANDU plants in the short to medium term. Three conceptual designs have been developed that use supercritical water (SCW) as a coolant. The increased coolant temperature results in the thermodynamic efficiency of each CANDU-X concept being significantly higher than conventional nuclear plants. The first concept, CANDU-X Mark 1, is a logical extension of the current CANDU design to higher operating temperatures. To take maximum advantage of the high heat capacity of water at the pseudo-critical temperature, water at nominally 25 MPa enters the core at 310{sup o}C, and exits at {approx}410{sup o}C. The high specific heat also leads to high heat transfer coefficients between the fuel cladding and the coolant. As a result, Zr-alloys can be used as cladding, thereby retaining relatively high neutron economy. The second concept, CANDU-X NC, is aimed at markets that require smaller simpler distributed

  7. Conceptual designs for very high-temperature CANDU reactors

    International Nuclear Information System (INIS)

    Bushby, S.J.; Dimmick, G.R.; Duffey, R.B.

    2000-01-01

    Although its environmental benefits are demonstrable, nuclear power must be economically competitive with other energy sources to ensure it retains, or increases, its share of the changing and emerging energy markets of the next decades. In recognition of this, AECL is studying advanced reactor concepts with the goal of significant reductions in capital cost through increased thermodynamic efficiency and plant simplification. The program, generically called CANDU-X, examines concepts for the future, but builds on the success of the current CANDU designs by keeping the same fundamental design characteristics: excellent neutron economy for maximum flexibility in fuel cycle; an efficient heavy-water moderator that provides a passive heat sink under upset conditions; and, horizontal fuel channels that enable on-line refueling for optimum fuel utilization and power profiles. Retaining the same design fundamentals takes maximum advantage of the existing experience base, and allows technological and design improvements developed for CANDU-X to be incorporated into more evolutionary CANDU plants in the short to medium term. Three conceptual designs have been developed that use supercritical water (SCW) as a coolant. The increased coolant temperature results in the thermodynamic efficiency of each CANDU-X concept being significantly higher than conventional nuclear plants. The first concept, CANDU-X Mark 1, is a logical extension of the current CANDU design to higher operating temperatures. To take maximum advantage of the high heat capacity of water at the pseudo-critical temperature, water at nominally 25 MPa enters the core at 310 o C, and exits at ∼410 o C. The high specific heat also leads to high heat transfer coefficients between the fuel cladding and the coolant. As a result, Zr-alloys can be used as cladding, thereby retaining relatively high neutron economy. The second concept, CANDU-X NC, is aimed at markets that require smaller simpler distributed power plants

  8. Development of fabrication technology for CANDU advanced fuel -Development of the advanced CANDU technology-

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Chang Beom; Kim, Hyeong Soo; Kim, Sang Won; Seok, Ho Cheon; Shim, Ki Seop; Byeon, Taek Sang; Jang, Ho Il; Kim, Sang Sik; Choi, Il Kwon; Cho, Dae Sik; Sheo, Seung Won; Lee, Soo Cheol; Kim, Yoon Hoi; Park, Choon Ho; Jeong, Seong Hoon; Kang, Myeong Soo; Park, Kwang Seok; Oh, Hee Kwan; Jang, Hong Seop; Kim, Yang Kon; Shin, Won Cheol; Lee, Do Yeon; Beon, Yeong Cheol; Lee, Sang Uh; Sho, Dal Yeong; Han, Eun Deok; Kim, Bong Soon; Park, Cheol Joo; Lee, Kyu Am; Yeon, Jin Yeong; Choi, Seok Mo; Shon, Jae Moon [Korea Atomic Energy Res. Inst., Taejon (Korea, Republic of)

    1994-07-01

    The present study is to develop the advanced CANDU fuel fabrication technologies by means of applying the R and D results and experiences gained from localization of mass production technologies of CANDU fuels. The annual portion of this year study includes following: 1. manufacturing of demo-fuel bundles for out-of-pile testing 2. development of technologies for the fabrication and inspection of advanced fuels 3. design and munufacturing of fuel fabrication facilities 4. performance of fundamental studies related to the development of advanced fuel fabrication technology.

  9. Mathematical modeling of CANDU-PHWR

    Energy Technology Data Exchange (ETDEWEB)

    Gaber, F.A.; Aly, R.A.; El-Shal, A.O. [Atomic Energy Authority, Cairo (Egypt)

    2001-07-01

    The paper deals with the transient studies of CANDU 600 pressurized Heavy Water Reactor (PHWR) system. This study involved mathematical modeling of CANDU PHWR major system components and the developments of software to study the thermodynamic performances. Modeling of CANDU-PHWR was based on lumped parameter technique.The integrated CANDU-PHWR model includes the neutronic, reactivity, fuel channel heat transfer, piping and the preheater type U-tube steam generator (PUTSG). The nuclear reactor power was modelled using the point kinetics equations with six groups of delayed neutrons and reactivity feed back due to the changes in fuel temperature and coolant temperature. The complex operation of the preheater type U-tube steam generator (PUTSG) is represented by a non-linear dynamic model using a state variable, moving boundary and lumped parameter techniques. The secondary side of the PUTSG model has six separate lumps including a preheater region, a lower boiling section, a mixing region, a riser, a chimmeny section, and a down-corner. The tube side of PUTSG has three main thermal zones. The PUTSG model is based on conservation of mass, energy and momentum relation-ships. The CANDU-PHWR integrated model are coded in FORTRAN language and solved by using a standard numerical technique. The adequacy of the model was tested by assessing the physical plausibility of the obtained results. (author)

  10. CANDU fuel cycle options in Korea

    International Nuclear Information System (INIS)

    Boczar, P. G.; Fehrenbach, P. J.; Meneley, D. A.

    1996-01-01

    FBR reactors. If the objective of a national fuel-cycle program is the minimization of actinide waste or destruction of long-lived fission products, then studies have shown the superiority of CANDU reactors in meeting this objective. Long-term energy security can be assured either through the thorium cycle or through a CANDU/FBR system, in which the FBR would be operated as a 'fuel factory,'providing the fissile material to power a number of lower-cost, high-efficiency CANDU reactors. In summary, the CANDU reactor's simple fuel design, high neutron economy, and on-line fuelling provide flexibility to respond to changing fuel-cycle requirements in the short term and in the indefinite future

  11. Experience with digital instrumentation and control systems for CANDU power plant modifications

    International Nuclear Information System (INIS)

    Basu, S.

    1997-01-01

    Over the last years, Ontario Hydro CANDU power plants have gone through many modifications. This includes modification from analog hardwired controls to digital and solid state controls and replacement of the existing digital controls with the latest hardware and software technology. Examples of digital modifications at Bruce A and other CANDU power plants are briefly described and categorized. Most of the I and C technology development has been supported by the CANDU Owners Group (COG) a consortium of Canadian nuclear utilities and the Atomic Energy Canada Limited (AECL). (author)

  12. Experience with digital instrumentation and control systems for CANDU power plant modifications

    Energy Technology Data Exchange (ETDEWEB)

    Basu, S [Ontario Hydro, Toronto, ON (Canada)

    1997-07-01

    Over the last years, Ontario Hydro CANDU power plants have gone through many modifications. This includes modification from analog hardwired controls to digital and solid state controls and replacement of the existing digital controls with the latest hardware and software technology. Examples of digital modifications at Bruce A and other CANDU power plants are briefly described and categorized. Most of the I and C technology development has been supported by the CANDU Owners Group (COG) a consortium of Canadian nuclear utilities and the Atomic Energy Canada Limited (AECL). (author).

  13. Technologies in support of CANDU development

    International Nuclear Information System (INIS)

    Turner, C.; Tapping, B.

    2005-01-01

    Atomic Energy of Canada, Ltd. (AECL) has significant research and development (R and D) programs designed to meet the needs of both existing CANDU reactors and new and evolving CANDU plant designs. These R and D programs cover a wide range of technology, from chemistry and materials support through to inspection and life management tools. Emphasis is placed on effective technology development programs for fuel channels, feeders and steam generators to ensure their operation through design life, and beyond. This paper specifically addresses how the R and D has been applied in the production of longer-lived pressure tubes for the most recent CANDU 6 reactors, and how this technology forms the basis for the pressure tubes of the Advanced CANDU Reactor (ACR). Similarly, AECL has developed solutions for other critical components such as calandria tubes, feeder pipe and steam generators. The paper also discusses how the R and D knowledge has been integrated into aging management databases and health monitoring tools. Since 1997, AECL has been working with CANDU utilities on comprehensive and integrated CANDU Plant Life Management (PLiM) programs for successful and reliable plant operation through design life and beyond. AECL has developed and implemented an advanced chemistry monitoring and diagnostic system, called ChemAND which allows on-line access by the operators to current and past chemistry conditions enabling appropriate responses and facilitating planning of shutdown maintenance actions. An equivalent tool for monitoring, trending and diagnosing thermal and mechanical data has also been developed; this tool is called ThermAND. AECL is developing the Maintenance Information, Monitoring, and Control (MIMC) system, which provide information to the user for condition-based decision-making in maintenance. To enable more effective inspections, surveillance and data collection, AECL has developed unique one-off tooling to carry out unanticipated inspection and repair

  14. Optimization and implementation study of plutonium disposition using existing CANDU Reactors. Final report

    International Nuclear Information System (INIS)

    1996-09-01

    Since early 1994, the Department of Energy has been sponsoring studies aimed at evaluating the merits of disposing of surplus US weapons plutonium as Mixed Oxide (MOX) fuel in existing commercial Canadian Pressurized Heavy Water reactors, known as CANDU's. The first report, submitted to DOE in July, 1994 (the 1994 Executive Summary is attached), identified practical and safe options for the consumption of 50 to 100 tons of plutonium in 25 years in some of the existing CANDU reactors operating the Bruce A generating station, on Lake Huron, about 300 km north east of Detroit. By designing the fuel and nuclear performance to operate within existing experience and operating/performance envelope, and by utilizing existing fuel fabrication and transportation facilities and methods, a low cost, low risk method for long term plutonium disposition was developed. In December, 1995, in response to evolving Mission Requirements, the DOE requested a further study of the CANDU option with emphasis on more rapid disposition of the plutonium, and retaining the early start and low risk features of the earlier work. This report is the result of that additional work

  15. Key thrusts in next generation CANDU. Annex 10

    International Nuclear Information System (INIS)

    Shalaby, B.A.; Torgerson, D.F.; Duffey, R.B.

    2002-01-01

    Current electricity markets and the competitiveness of other generation options such as CCGT have influenced the directions of future nuclear generation. The next generation CANDU has used its key characteristics as the basis to leap frog into a new design featuring improved economics, enhanced passive safety, enhanced operability and demonstrated fuel cycle flexibility. Many enabling technologies spinning of current CANDU design features are used in the next generation design. Some of these technologies have been developed in support of existing plants and near term designs while others will need to be developed and tested. This paper will discuss the key principles driving the next generation CANDU design and the fuel cycle flexibility of the CANDU system which provide synergism with the PWR fuel cycle. (author)

  16. Advanced CANDU reactors

    International Nuclear Information System (INIS)

    Dunn, J.T.; Finlay, R.B.; Olmstead, R.A.

    1988-12-01

    AECL has undertaken the design and development of a series of advanced CANDU reactors in the 700-1150 MW(e) size range. These advanced reactor designs are the product of ongoing generic research and development programs on CANDU technology and design studies for advanced CANDU reactors. The prime objective is to create a series of advanced CANDU reactors which are cost competitive with coal-fired plants in the market for large electricity generating stations. Specific plant designs in the advanced CANDU series will be ready for project commitment in the early 1990s and will be capable of further development to remain competitive well into the next century

  17. Thermosyphoning in the CANDU reactor

    International Nuclear Information System (INIS)

    Spinks, N.J.; Wright, A.C.D.; Caplan, M.Z.; Prawirosoehardjo, S.; Gulshani, P.

    1984-01-01

    Thermosyphoning is defined as the natural convective flow of primary coolant over the boilers. It is the predicted mode of heat transport from core to boilers in many postulated scenarios for CANDU reactor safety analysis. The scenarios encompass a wide range of boundary conditions in reactor power, secondary temperature and primary coolant inventory. Loss of pumping of the primary coolant is a common feature. Thermosyphoning is single or two-phase depending on the boundary conditions. The paper describes the important thermohydraulic characteristics of thermosyphoning in CANDU reactors with emphasis on two-phase thermosyphoning. It utilizes predictions of a transient thermohydraulics computer code and describes experiments done for the purpose of verifying these predictions. Predictions are compared with single-phase thermosyphoning tests done during commissioning of the Gentilly-2 and Point Lepreau CANDU 600 reactors. (orig.)

  18. Verification tests for CANDU advanced fuel

    International Nuclear Information System (INIS)

    Chung, Chang Hwan; Chang, S.K.; Hong, S.D.

    1997-07-01

    For the development of a CANDU advanced fuel, the CANFLEX-NU fuel bundles were tested under reactor operating conditions at the CANDU-Hot test loop. This report describes test results and test methods in the performance verification tests for the CANFLEX-NU bundle design. The main items described in the report are as follows. - Fuel bundle cross-flow test - Endurance fretting/vibration test - Freon CHF test - Production of technical document. (author). 25 refs., 45 tabs., 46 figs

  19. Experience in the application of NUSS and Canadian quality assurance standards for overseas CANDU projects

    International Nuclear Information System (INIS)

    Simmons, R.B.V.; Thomas, R.A.

    1984-10-01

    The Canadian QA standards - the CSA Z299 series for manufacture, which first appeared in 1975, and the CSA N286 series for all other phases of plant life which appeared in 1979, have been based on experience with the CANDU reactor program. The CSA Technical Committee responsible for issue and for updating the two series have a direct liaison with the IAEA Technical Review Committee for Quality Assurance. Ontario Hydro, which has a substantial commitment to nuclear power using CANDU reactors, has played a large part in the Canadian QA standards program. Atomic Energy of Canada Limited has also taken a major part in the development of CSA QA standards. As a main contractor the Company has supplied CANDU plants in Canada and to Argentina, South Korea and Romania. Because of the compatibility of the Canadian QA standards used, the Embalse plant in Argentina and the Wolsung 1 plant in Korea, are essentially in compliance with NUSS QA standards. The plant under construction at Cernavoda in Romania similarly follows Canadian QA standards

  20. Candu Energy's Aging and Obsolescence Program and its Application to Operating Facilities and New Plant Design

    International Nuclear Information System (INIS)

    Dam, R.; Gold, R.; McCrea, L.

    2012-01-01

    While plant aging is inevitable, predictable and 'graceful 'aging' behavior can be achieved through the implementation of a comprehensive and integrated Plant Life Management (PLiM) program. Despite organizations like the IAEA and INPO placing more emphasis on equipment reliability, there is still a lack of completely integrated programs in the industry as evidenced by: - Piece-meal, often crisis-driven, implementation comprising many different, partial solutions; - Duplication of effort often seen when different groups work in 'silos'. A strategy which fits with existing plant processes and programs, and which coordinates a broad range of equipment reliability activities is key to achieving the desired results. An example of such a program is the Aging and Obsolescence Program (AOP). AOP follows application of INPO AP-913 guidance for equipment reliability. The program is augmented to include single point vulnerability identification, unified approach to short and long lived components, risk management, spare parts management, and the identification and resolution of obsolescence issues. The systematic nature of the program provides the needed foundation to old and new stations alike. For existing operating stations some of the key uses include outage interval extension, reduced forced outages, and/or outage time reduction, any of which can translate into improving plant performance, competitiveness, and significant dollars saved. Program elements applied to new plant design are commensurate with the industry direction to 'design for reliability', and has allowed Candu Energy to learn and to improve upon what it can offer to operating stations. This paper intends to describe the basic elements of Candu Energy's Aging and Obsolescence Program and will share some of the experience having applied it to existing operating stations, consider applications to support expanding regulatory requirements, and describe the integration into the design of new plants, promoting

  1. A study for good regulatin of the CANDU's in Korea. Development of safety regulatory requirement for CANDU nuclear power plants

    Energy Technology Data Exchange (ETDEWEB)

    Oh, Se Ki; Shin, Y. K.; Kim, J. S.; Yu, Y. J.; Lee, Y. J. [Ajou Univ., Suwon (Korea, Republic of)

    2001-03-15

    The objective of project is to derive the policy recommendations to improve the efficiency of CANDU plants regulation. These policy recommendations will eventually contribute to the upgrading of Korean nuclear regulatory system and safety enhancement. During the first phase of this 2 years study, following research activities were done. On-site survey and analysis on CANDU plants regulation. Review on CANDU plants regulating experiences and current constraints. Review and analysis on the new Canadian regulatory approach.

  2. Evolution of the CANDU control centre retrofit and new stations

    International Nuclear Information System (INIS)

    Olmstead, R.A.; Mitchell, W.

    1991-01-01

    Significant event data from operating nuclear plants in many countries consistently indicates human errors are the root cause for 40-60% of operating station significant events. Because so much information is already in digital form, opportunities exist to improve the CANDU control centre with retrofits that exploit this information. These opportunities are enhanced because of rapid technological development in computers and electronics, coupled with significant progress in the behavioural sciences that greatly increases our knowledge of the cognitive strengths and weaknesses of human beings. CANDU control rooms are undergoing retrofits and for future CANDU stations, a new concept of the control centre is emerging. The objective is to significantly reduce the incidence of human error, reduce operations and maintenance costs and improve both reliability and safety

  3. Evolution of the CANDU control centre retrofit and new stations

    Energy Technology Data Exchange (ETDEWEB)

    Olmstead, R A [AECL-CANDU, ON (Canada); Mitchell, W [Ontario Hydro, Darlington Nuclear Generating Station, Bowmanville, ON (Canada)

    1991-04-01

    Significant event data from operating nuclear plants in many countries consistently indicates human errors are the root cause for 40-60% of operating station significant events. Because so much information is already in digital form, opportunities exist to improve the CANDU control centre with retrofits that exploit this information. These opportunities are enhanced because of rapid technological development in computers and electronics, coupled with significant progress in the behavioural sciences that greatly increases our knowledge of the cognitive strengths and weaknesses of human beings. CANDU control rooms are undergoing retrofits and for future CANDU stations, a new concept of the control centre is emerging. The objective is to significantly reduce the incidence of human error, reduce operations and maintenance costs and improve both reliability and safety.

  4. CANDU: study and review

    International Nuclear Information System (INIS)

    Morad, César M.; Santos, Thiago A. dos

    2017-01-01

    The CANDU (Canadian Deuterium Uranium) is a nuclear reactor developed by AECL (Atomic Energy of Canada Limited). The first small-scale reactor is known as NPD and was made in 1955 and commenced operation in 1962. It is a pressurized heavy water reactor and uses D2O as moderator and coolant and therefore uses natural uranium as fuel. There have been two major types of CANDU reactors, the original design of around 500 MWe that was intended to be used in multi-reactor installations in large plants, and the rationalized CANDU6 which has units in Argentina, South Korea, Pakistan, Romania and China. Throughout the 1980s and 90s the nuclear power market suffered a major crash, with few new plants being constructed in North America or Europe. Design work continued through, however, and a number of new design concepts were introduced that dramatically improved safety, capital costs, economics and overall performance. These Generation III+ and Generation IV machines became a topic of considerable interest in the early 2000s as it appeared a nuclear renaissance was underway and large numbers of new reactors would be built over the next decade. The present work aims to study the reactors of the CANDU type, exploring from its creation to studies directed to G-III and G-IV reactors. (author)

  5. CANDU: study and review

    Energy Technology Data Exchange (ETDEWEB)

    Morad, César M., E-mail: cesar.morad@usp.br [Universidade de São Paulo (POLI/USP), SP (Brazil). Escola Politécnica; Stefani, Giovanni L. de, E-mail: giovanni.stefani@ipen.br [Instituto de Pesquisas Energéticas e Nucleares (IPEN/CNEN-SP), São Paulo, SP (Brazil); Santos, Thiago A. dos, E-mail: thiago.santos@ufabc.edu.br [Universidade Federal do ABC (UFABC), Santo André, SP (Brazil)

    2017-07-01

    The CANDU (Canadian Deuterium Uranium) is a nuclear reactor developed by AECL (Atomic Energy of Canada Limited). The first small-scale reactor is known as NPD and was made in 1955 and commenced operation in 1962. It is a pressurized heavy water reactor and uses D2O as moderator and coolant and therefore uses natural uranium as fuel. There have been two major types of CANDU reactors, the original design of around 500 MWe that was intended to be used in multi-reactor installations in large plants, and the rationalized CANDU6 which has units in Argentina, South Korea, Pakistan, Romania and China. Throughout the 1980s and 90s the nuclear power market suffered a major crash, with few new plants being constructed in North America or Europe. Design work continued through, however, and a number of new design concepts were introduced that dramatically improved safety, capital costs, economics and overall performance. These Generation III+ and Generation IV machines became a topic of considerable interest in the early 2000s as it appeared a nuclear renaissance was underway and large numbers of new reactors would be built over the next decade. The present work aims to study the reactors of the CANDU type, exploring from its creation to studies directed to G-III and G-IV reactors. (author)

  6. CANDU reactors and greenhouse gas emissions

    International Nuclear Information System (INIS)

    Andseta, S.; Thompson, M.J.; Jarrell, J.P.; Pendergast, D.R.

    1999-01-01

    This paper was originally presented at the 11th Pacific Basin Nuclear Conference, Banff, Alberta, Canada, May 3-7, 1998. It has been updated to include additional lifecycle data on chemical releases from ore treatment and CANDU fuel fabrication. It is sometimes stated that nuclear power plants can supply electricity with zero emissions of greenhouse gases. In fact, consideration of the entire fuel cycle indicates that some greenhouse gases are generated during their construction and decommissioning and by the preparation of fuel and other materials required for their operation. This follows from the use of fossil fuels in the preparation of materials and during the construction and decommissioning of the plants. This paper reviews life cycle studies of several different kinds of power plants. Greenhouse gases generated by fossil fuels during the preparation of fuel and heavy water used by operating CANDU power plants are estimated. The total greenhouse gas emissions from CANDU nuclear plants, per unit of electricity ultimately produced, are very small in comparison with emissions from most other types of power plants. (author)

  7. CANDU reactors and greenhouse gas emissions

    International Nuclear Information System (INIS)

    Andseta, S.; Thompson, M.J.; Jarrell, J.P.; Pendergast, D.R.

    1998-01-01

    This paper was originally presented at the 11th Pacific Basin Nuclear Conference, Banff, Alberta, Canada, May 3-7, 1998. It has been updated to include additional lifecycle data on chemical releases from ore treatment and CANDU fuel fabrication. It is sometimes stated that nuclear power plants can supply electricity with zero emissions of greenhouse gases. In fact, consideration of the entire fuel cycle indicates that some greenhouse gases are generated during their construction and decommissioning and by the preparation of fuel and other materials required for their operation. This follows from the use of fossil fuels in the preparation of materials and during the construction and decommissioning of the plants. This paper reviews life cycle studies of several different kinds of power plants. Greenhouse gases generated by fossil fuels during the preparation of fuel and heavy water used by operating CANDU power plants are estimated. The total greenhouse gas emissions from CANDU nuclear plants, per unit of electricity ultimately produced, are very small in comparison with emissions from most other types of power plants. (author)

  8. Cost and schedule reduction for next-generation Candu

    International Nuclear Information System (INIS)

    Hopwood, J.M.; Yu, S.; Pakan, M.; Soulard, M.

    2002-01-01

    AECL has developed a suite of technologies for Candu R reactors that enable the next step in the evolution of the Candu family of heavy-water-moderated fuel-channel reactors. These technologies have been combined in the design for the Advanced Candu Reactor TM1 (ACRTM), AECL's next generation Candu power plant. The ACR design builds extensively on the existing Candu experience base, but includes innovations, in design and in delivery technology, that provide very substantial reductions in capital cost and in project schedules. In this paper, main features of next generation design and delivery are summarized, to provide the background basis for the cost and schedule reductions that have been achieved. In particular the paper outlines the impact of the innovative design steps for ACR: - Selection of slightly enriched fuel bundle design; - Use of light water coolant in place of traditional Candu heavy water coolant; - Compact core design with unique reactor physics benefits; - Optimized coolant and turbine system conditions. In addition to the direct cost benefits arising from efficiency improvement, and from the reduction in heavy water, the next generation Candu configuration results in numerous additional indirect cost benefits, including: - Reduction in number and complexity of reactivity mechanisms; - Reduction in number of heavy water auxiliary systems; - Simplification in heat transport and its support systems; - Simplified human-machine interface. The paper also describes the ACR approach to design for constructability. The application of module assembly and open-top construction techniques, based on Candu and other worldwide experience, has been proven to generate savings in both schedule durations and overall project cost, by reducing premium on-site activities, and by improving efficiency of system and subsystem assembly. AECL's up-to-date experience in the use of 3-D CADDS and related engineering tools has also been proven to reduce both engineering and

  9. Advancing CANDU Technology Through R and D

    International Nuclear Information System (INIS)

    Torgerson, David F.

    1993-01-01

    CANDU reactors are evolving to meet future requirements using incremental changes as opposed to revolutionary design changes. The main elements for advancing the technology reducing capital and operating, increasing capacity factors, increasing passive safety, and enhancing fuel/fuel cycle flexibility. These elements are being addressed by carrying out research and development in the areas of safety, plant systems and components, heavy water production, information technology, fuel channels, and fuel/fuel cycle technology. In safety, the focus is on using the inherent features of CANDU to enhance passive or natural safety concepts, such as the use of the moderator as an effective heat sink, and the development of advanced fuels to improve critical heat flux and to reduce source terms. Plant systems and components work includes improvements to plant systems such as steam generators, heat exchangers, pump seals, and advanced control room technology. Heavy water processes are being developed that can be used with existing hydrogen production plants, or that can be used in a stand-alone mode. Information technology is being developed to cover all aspects of CANDU design, construction, and operation. Fuel channel improvements include elucidation and application of basic materials science for life extension, and the development of advanced non-destructive examination methods. Fuel and fuel cycle work is focusing on LWR/CANDU synergy, such as the use of recovered uranium and the direct use of spent PWR fuel in CANDU reactor, advanced fuels to improve burnup and economics (e. g., the joint AECB/KAERI Conflux program), and low void reactivity fuel to enhance passive safety. This paper gives an overview of some of the R and D supporting these activities, with particular emphasis on Alice's vision for advancing CANDU technology over the next 10 years

  10. MAAP4 CANDU analysis of a generic CANDU-6 plant: preliminary results

    Energy Technology Data Exchange (ETDEWEB)

    Petoukhov, S.M.; Mathew, P.M

    2001-10-01

    To support the generic probabilistic safety analysis (PSA) program at AECL, in particular to conduct Level 2 PSA analysis of a CANDU 6 plant undergoing a postulated severe accident, the capability to conduct severe accident consequence analysis for a CANDU plant is required. For this purpose, AECL selected MAAP4 CANDU from a number of other severe accident codes. The necessary models for a generic CANDU 6 station have been implemented in the code, and the code version 0.2 beta was tested using station data, which were assembled for a generic CANDU 6 station. This paper describes the preliminary results of the consequence analysis using MAAP4 CANDU for a generic CANDU 6 station, when it undergoes a station blackout and a large loss-of-coolant accident scenario. The analysis results show that the plant response is consistent with the physical phenomena modeled and the failure criteria used. The results also confirm that the CANDU design is robust with respect to severe accidents, which is reflected in the calculated long times that are available for administering accident management measures to arrest the accident progression before the calandria vessel or containment become at risk. (author)

  11. Development situation about the Canadian CANDU Nuclear Power Generating Stations

    Energy Technology Data Exchange (ETDEWEB)

    Jeon, Yu Mi; Kim, Yong Hee; Park, Joo Hwan

    2009-07-15

    The CANDU reactor is the most versatile commercial power reactor in the world. The acronym 'CANDU', a registered trademark of Atomic Energy of Canada Limited, stands for 'CANada Deuterium Uranium'. CANDU uses heavy water as moderator and uranium (originally, natural uranium) as fuel. All current power reactors in Canada are of the CANDU type. Canada exports CANDU type reactor in abroad. CANDU type is used as the nuclear power plants to produce electrical. Today, there are 41 CANDU reactors in use around the world, and the design has continuously evolved to maintain into unique technology and performance. The CANDU-6 power reactor offers a combination of proven, superior and state-of-the-art technology. CANDU-6 was designed specifically for electricity production, unlike other major reactor types. One of its characteristics is a very high operating and fuel efficiency. Canada Nuclear Power Generating Stations were succeeded in a commercial reactor of which the successful application of heavy water reactor, natural uranium method and that on-power fuelling could be achieved. It was achieved through the joint development of a major project by strong support of the federal government, public utilities and private enterprises. The potential for customization to any country's needs, with competitive development and within any level of domestic industrial infrastructure, gives CANDU technology strategic importance in the 21st century.

  12. Development situation about the Canadian CANDU Nuclear Power Generating Stations

    International Nuclear Information System (INIS)

    Jeon, Yu Mi; Kim, Yong Hee; Park, Joo Hwan

    2009-07-01

    The CANDU reactor is the most versatile commercial power reactor in the world. The acronym 'CANDU', a registered trademark of Atomic Energy of Canada Limited, stands for 'CANada Deuterium Uranium'. CANDU uses heavy water as moderator and uranium (originally, natural uranium) as fuel. All current power reactors in Canada are of the CANDU type. Canada exports CANDU type reactor in abroad. CANDU type is used as the nuclear power plants to produce electrical. Today, there are 41 CANDU reactors in use around the world, and the design has continuously evolved to maintain into unique technology and performance. The CANDU-6 power reactor offers a combination of proven, superior and state-of-the-art technology. CANDU-6 was designed specifically for electricity production, unlike other major reactor types. One of its characteristics is a very high operating and fuel efficiency. Canada Nuclear Power Generating Stations were succeeded in a commercial reactor of which the successful application of heavy water reactor, natural uranium method and that on-power fuelling could be achieved. It was achieved through the joint development of a major project by strong support of the federal government, public utilities and private enterprises. The potential for customization to any country's needs, with competitive development and within any level of domestic industrial infrastructure, gives CANDU technology strategic importance in the 21st century

  13. Design and analysis of CANDU advanced fuel -Development of the advanced CANDU technology-

    International Nuclear Information System (INIS)

    Seok, Ho Cheon; Shim, Ki Seop; Byeon, Taek Sang; Park, Kwang Seok; Kim, Bong Ki; Lee, Yeong Uk; Jeong, Chang Joon; Oh, Deok Joo; Lee, Ui Joo; Park, Joo Hwan; Lee, Sang Yong; Jeong, Beop Dong; Choi, Han Rim; Lee, Yeong Jin; Choi, Cheol Jin; Choi, Jong Ho; Lee, Kwang Won; Cho, Cheon Hyi; On, Myeong Ryong; Kim, Taek Mo; Lim, Hong Sik; Lee, Kang Moon; Lee, Nam Ho; Lee, Kyu Hyeong

    1994-07-01

    It has been projected that a total of 5 pressurized heavy water reactors (PHWR) including Wolsong 1 under operation and Wolsong 2, 3 and 4 under construction will be operated by 2006, and so about 500 ton of natural uranium will be consumed every year and a lot of spent fuels will be generated. Therefore, the ultimate goal of this R and D project is to develop the CANDU advanced fuel having the following capabilities compared with existing standard fuel: (1) To reduce linear heat generation rating by more than 15% (i.e., less than 50 kW/m), (2) To extend fuel burnup by more than 3 times (i.e., higher than 21,000 MWD/MTU), and (3) To increase critical channel power by more than 5%. In accordance, the followings are performed in this fiscal year: (1) Undertake CANFLEX-NU design and thermalmechanical performance analysis, and prepare design documents, (2) Establish reactor physics analysis code system, and investigate the compativility of the CANFLEX-NU fuel with the standard 37-element fuel in the CANDU-6 reactor. (3) Establish safety analysis methodology with the assumption of the CANFLEX-NU loaded CANDU-6 reactor, and perform the preliminary thermalhydraulic and fuel behavior for the selected DBA accidents, (4) Investigate reactor physics analysis code system as pre-study for CANFLEX-SEU loaded reactors

  14. Diagnostic Technology Development for Core Internal Structure in CANDU reactor

    International Nuclear Information System (INIS)

    Jung, Hyun Kyu; Cheong, Y. M.; Lee, Y. S. and others

    2005-04-01

    Degradation of critical components of nuclear power plants has become important as the operating years of plants increase. The necessity of degradation study including measurement and monitoring technology has increased continuously. Because the fuel channels and the neighboring sensing tubes and control rods are particularly one of the critical components in CANDU nuclear plant, they are treated as a major research target in order to counteract the possible problems and establish the counterplan for the CANDU reactor safety improvement. To ensure the core structure integrity in CANDU nuclear plant, the following 2 research tasks were performed: Development of NDE technologies for the gap measurement between the fuel channels and LIN tubes. Development of vibration monitoring technology of the fuel channels and sensing tubes. The technologies developed in this study could contribute to the nuclear safety and estimation of the remaining life of operating CANDU nuclear power plants

  15. CANDU type fuel behavior evaluation - a probabilistic approach

    International Nuclear Information System (INIS)

    Moscalu, D.R.; Horhoianu, G.; Popescu, I.A.; Olteanu, G.

    1995-01-01

    In order to realistically assess the behavior of the fuel elements during in-reactor operation, probabilistic methods have recently been introduced in the analysis of fuel performance. The present paper summarizes the achievements in this field at the Institute for Nuclear Research (INR), pointing out some advantages of the utilized method in the evaluation of CANDU type fuel behavior in steady state conditions. The Response Surface Method (RSM) has been selected for the investigation of the effects of the variability in fuel element computer code inputs on the code outputs (fuel element performance parameters). A new developed version of the probabilistic code APMESRA based on RSM is briefly presented. The examples of application include the analysis of the results of an in-reactor fuel element experiment and the investigation of the calculated performance parameter distribution for a new CANDU type extended burnup fuel element design. (author)

  16. CANDU plant maintenance: Recent developments

    International Nuclear Information System (INIS)

    Charlebois, P.

    2000-01-01

    CANDU units have long been recognized for their exceptional safety and reliability. Continuing development in the maintenance area has played a key role in achieving this performance level. For over two decades, safety system availability has been monitored closely and system maintenance programs adjusted accordingly to maintain high levels of performance. But as the plants approach mid life in a more competitive environment and component aging becomes a concern, new methods and techniques are necessary. As a result, recent developments are moving the maintenance program largely from a corrective and preventive approach to predictive and condition based maintenance. The application of these techniques is also being extended to safety related systems. These recent developments include use of reliability centred methods to define system maintenance requirements and strategies. This approach has been implemented on a number of systems at Canadian CANDU plants with positive results. The pilot projects demonstrated that the overall maintenance effort remained relatively constant while the system performance improved. It was also possible to schedule some of the redundant component maintenance during plant operation without adverse impact on system availability. The probabilistic safety assessment was found to be useful in determining the safety implications of component outages. These new maintenance strategies are now making use of predictive and condition based maintenance techniques to anticipate equipment breakdown and schedule preventive maintenance as the need arises rather than time based. Some of these techniques include valve diagnostics, vibration monitoring, oil analysis, thermography. Of course, these tools and techniques must form part of an overall maintenance management system to ensure that maintenance becomes a living program. To facilitate this process and contain costs, new information technology tools are being introduced to provide system engineers

  17. CANDU Safety R&D Status, Challenges, and Prospects in Canada

    Directory of Open Access Journals (Sweden)

    W. Shen

    2015-01-01

    Full Text Available In Canada, safe operation of CANDU (CANada Deuterium Uranium; it is a registered trademark of Atomic Energy of Canada Limited reactors is supported by a full-scope program of nuclear safety research and development (R&D in key technical areas. Key nuclear R&D programs, facilities, and expertise are maintained in order to address the unique features of the CANDU as well as generic technology areas common to CANDU and LWR (light water reactor. This paper presents an overview of the CANDU safety R&D which includes background, drivers, current status, challenges, and future directions. This overview of the Canadian nuclear safety R&D programs includes those currently conducted by the COG (CANDU Owners Group, AECL (Atomic Energy of Canada Limited, Candu Energy Inc., and the CNSC (Canadian Nuclear Safety Commission and by universities via UNENE (University Network of Excellence in Nuclear Engineering sponsorship. In particular, the nuclear safety R&D program related to the emerging CANDU ageing issues is discussed. The paper concludes by identifying directions for the future nuclear safety R&D.

  18. Future generations of CANDU: advantages and development with passive safety

    International Nuclear Information System (INIS)

    Duffey, R. B.

    2006-01-01

    Atomic Energy of Canada Limited (AECL) advances water reactor and CANDLT technology using an evolutionary development strategy. This strategy ensures that innovations are based firmly on current experience and keeps our development programs focused on one reactor concept, reducing risks, development costs, and product development cycle times. It also assures our customers that our products will never become obsolete or unsupported, and the continuous line of water reactor development is secure and supported into the future. Using the channel reactor advantage of modularity, the subdivided core has the advantage of passive safety by heat removal to the low- pressure moderator. With continuous improvements, the Advanced CANDU Reactor TM (ACR-1000TM) concept will likely remain highly competitive for a number of years and leads naturally to the next phase of CANDU development, namely the Generation IV CANDU -SCWR concept. This is conventional water technology, since supercritical boilers and turbines have been operating for some time in coal-fired power plants. Significant cost, safety, and performance advantages would result from the CANDU-SCWR concept, plus the flexibility of a range of plant sizes suitable for both small and large electric grids, and the ability for co-generation of electric power, process heat, and hydrogen. In CANDU-SCWR, novel developments are included in the primary circuit layout and channel design. The R and D in Canada is integrated with the Generation IV international Forum (GIF) plans, and has started on examining replaceable insulating liners that would ensure channel life, and on providing completely passive reactor decay heat removal directly to the moderator heat sink without forced cooling. In the interests of sustainability, hydrogen production by a CANDU- SCWR is also be included as part of the system requirements, where the methods for hydrogen production will depend on the outlet temperature of the reactor

  19. CANDU 3 - Modularization

    International Nuclear Information System (INIS)

    McAskie, M.J.

    1991-01-01

    The CANDU 3 Heavy Water Reactor is the newest design developed by AECL CANDU. It has set as a major objective, the achievement of significant reductions in both cost and schedule over previous designs. The basic construction strategy is to incorporate extensive modularization of the plant in order to parallel the civil and mechanical installation works. This results in a target 38 month construction schedule from first concrete to in-service compared to 68 months for the Wolsong-1 CANDU 6 actually achieved and the 54 months envisaged for an improved CANDU 6. This paper describes the module concepts that have been developed and explains how they contribute to the overall construction program and achieve the desired cost and schedule targets set for the CANDU 3. (author). 7 figs, 2 tabs

  20. CANDU fuel quality and how it is achieved

    International Nuclear Information System (INIS)

    Gacesa, M.; Quarrington, G.R.; Tarasuk, W.R.; Carrick, I.R.; Pawliw, J.; McGregor, G.; Debnam, H.R.; Proos, L.

    1980-07-01

    In this three part presentation CANDU fuel quality is reviewed from the point of view of a designer/operator and a fabricator. In Part 'A' fuel performance and quality considerations are discussed from the point of view of a designer-operator. In Parts 'B' and 'C' fuel quality is reviewed from the point of view of a fabricator. The presentation was divided in this way to convey the 'team effort' attitude which exists in the Canadian program; the team effort which is an essential part of the CANDU story. (auth)

  1. Development of a Web-based CANDU Core Management Procedure Automation System

    International Nuclear Information System (INIS)

    Lee, Sanghoon; Kim, Eunggon; Park, Daeyou; Yeom, Choongsub; Suh, Hyungbum; Kim, Sungmin

    2006-01-01

    CANDU reactor core needs efficient core management to increase safety, stability, high performance as well as to decrease operational cost. The most characteristic feature of CANDU is so called 'on-power refueling' i.e., there is no shutdown during refueling in opposition to that of PWR. Although this on-power refueling increases the efficiency of the plant, it requires heavy operational task and difficulties in real time operation such as regulating power distribution, burnup distribution, LZC statistics, the position of control devices and so on. To enhance the CANDU core management, there are several approaches to help operator and reduce difficulties, one of them is the COMOS (CANDU Core On-line Monitoring System). It has developed as an online core surveillance system based on the standard incre instrumentation and the numerical analysis codes such as RFSP (Reactor Fueling Simulation Program). As the procedure is getting more complex and the number of programs is increased, it is required that integrated and cooperative system. So, KHNP and IAE have been developing a new web-based system which can support effective and accurate reactor operational environment called COMPAS that means CANDU cOre Management Procedure Automation System. To ensure development of successful system, several steps of identifying requirements have been performed and Software Requirement Specification (SRS) document was developed. In this paper we emphasis on the how to keep consistency between the requirements and system products by applying requirement traceability methodology

  2. CANDU 6 probabilistic safety study summary

    International Nuclear Information System (INIS)

    1988-07-01

    This report summarizes the methodology, phenomenology and results relevent to the assessment of severe events in a CANDU 6 (formerly designated CANDU 600) station. The station design being analysed is based on a CANDU 6 Mark I currently operating in Canada. This evaluation includes event frequency and fission product release assessments but does not include assessment of radiation dose to the public, so that the information is equivalent to a level 2 Probabilistic Risk Assessment (PRA). The study has shown that the predicted overall average frequency for core melt in a CANDU 6 Mark I is 4.4 x 10 -6 events/year. This low frequency is, in large part due to the heavy water moderator which acts as a heat sink, prevents UO 2 melting and maintains core geometry for many events which could otherwise result in a core melt. The consequences for most core melts will be limited to the release of a fraction of noble gases and organic iodides. Other isotopes will be condensed or dissolved in the containment atmosphere and are ultimately retained in the pool of water in the basement where they are unavailable for release. Most core melts (∼ 90%) can be mitigated by operator action so that there is no danger of consequential damage to the containment structure and leak tightness. The frequency and consequences of less likely, more severe core melt sequences are also discussed in this report and shown to be small contributors to public risk

  3. Development of a new bundle welding technology for CANDU fuels

    International Nuclear Information System (INIS)

    Kim, Soo Sung; Lee, D. Y.; Goo, D. S.

    2010-01-01

    The new technology of welding process for fuel bundle of CANDU nuclear fuels is considered important in respect to the soundness of weldments and the improvement of the performance of nuclear fuels during the operation in reactor. The probability of leakage of the fission products is mostly apt to occur at the weldments of fuel bundles, and it is connected directly with the safety and life prediction of the nuclear reactor in operation. The fuel bundles of CANDU nuclear fuels are welded by the electrical resistance method, connecting the endplates and endcaps with fuel rods. Therefore, the purpose of this study of the 2nd year is to select the proper welding parameters and to investigate the characteristics of the full-sized samples using the projection endplates and make some prototype samples for the endplate welding of CANDU nuclear fuels. This study will be also provide the fundamental data for the new design and fabrications of CANDU nuclear fuel bundles

  4. Development of thermal hydraulic evaluation code for CANDU reactors

    International Nuclear Information System (INIS)

    Kim, Man Woong; Yu, Seon Oh; Choi, Yong Seog; Shin, Chull; Hwang, Soo Hyun

    2004-02-01

    To enhance the safety of operating CANDU reactors, the establishment of the safety analysis codes system for CANDU reactors is in progress. As for the development of thermal-hydraulic analysis code for CANDU system, the studies for improvement of evaluation model inside RELAP/CANDU code and the development of safety assessment methodology for GSI (Generic Safety Issues) are in progress as a part of establishment of CANDU safety assessment system. To develop the 3-D thermal-hydraulic analysis code for moderator system, the CFD models for analyzing the CANDU-6 moderator circulation are developed. One model uses a structured grid system with the porous media approach for the 380 Calandria tubes in the core region. The other uses a unstructured grid system on the real geometry of 380 Calandria tubes, so that the detailed fluid flow between the Calandria tubes can be observed. As to the development of thermal-hydraulic analysis code for containment, the study on the applicability of CONTAIN 2.0 code to a CANDU containment was conducted and a simulation of the thermal-hydraulic phenomena during the accident was performed. Besides, the model comparison of ESFs (Engineered Safety Features) inside CONTAIN 2.0 code and PRESCON code has also conducted

  5. Nuclear power - replacement of pressure tubes in CANDU reactors

    International Nuclear Information System (INIS)

    Anon.

    1992-01-01

    The CANDU pressure tube reactor is an effective electricity generator. While most units have been built in Canada, units are successfully operated in Argentina and Korea as well as India and Pakistan, which have early versions of the same concept. Units are also under construction in Korea and Romania. The main constructional components of a CANDU core are the calandria vessel, the fuel channels and the reactivity control mechanisms. The fuel channel, in particular the pressure tubes, see an environment comprising high flux, high temperature water at high pressures, which induces changes in the properties and dimensions of the channel components. From the first, fuel channels were designed to be replaced because of the difficulty in predicting the behaviour of zirconium alloys in such service over a long period of time. In fact some phenomena, that were not known at the time of the earliest designs, have led to unacceptable changes in the properties of the channels and these early reactors have had to be retubed at half their intended life. These deficiencies have been corrected in the latest designs and fuel channels in reactors that have commenced operation over the last 10 years, are predicted to reach the intended 30 years life before replacement is necessary. The changing of fuel channels, the details and experience of which are explained, has been shown to be an effective way of refurbishing the CANDU reactor, extending its lifetime a further 25-30 years. (author)

  6. Multi-purpose use of the advanced CANDU compact simulator

    International Nuclear Information System (INIS)

    Lam, K.Y.; MacBeth, M.J.

    1997-01-01

    A near full-scope dynamic model of a CANDU-PHWR (Canadian Deuterium Uranium Pressurized Heavy Water) nuclear power plant was constructed as a multi-purpose advanced Compact Simulator using CASSIM (Cassiopeia Simulation) development system. This Compact Simulator has played an integral part in the design and verification of the CANDU 900 MW control centre mock-up located in the Atomic Energy of Canada (AECL) design office, providing CANDU plant process dynamic data to the Plant Display System (PDS) and the Distributed Control System (DCS), as well as mock-up panel devices. As a design tool, the Compact Simulator is intended to be used for control strategy development, human factors studies, analysis of overall plant control performance, tuning estimates for major control loops. As a plant commissioning and operational strategy development tool, the simulation is intended to be used to evaluate routine and non-routine operational procedures, practice 'what-if' scenarios for operational strategy development, practice malfunction recovery procedures and verify human factors activities

  7. Verification tests for CANDU advanced fuel -Development of the advanced CANDU technology-

    International Nuclear Information System (INIS)

    Chung, Jang Hwan; Suk, Ho Cheon; Jeong, Moon Ki; Park, Joo Hwan; Jeong, Heung Joon; Jeon, Ji Soo; Kim, Bok Deuk

    1994-07-01

    This project is underway in cooperation with AECL to develop the CANDU advanced fuel bundle (so-called, CANFLEX) which can enhance reactor safety and fuel economy in comparison with the current CANDU fuel and which can be used with natural uranium, slightly enriched uranium and other advanced fuel cycle. As the final schedule, the advanced fuel will be verified by carrying out a large scale demonstration of the bundle irradiation in a commercial CANDU reactor, and consequently will be used in the existing and future CANDU reactors in Korea. The research activities during this year Out-of-pile hydraulic tests for the prototype of CANFLEX bundle was conducted in the CANDU-hot test loop at KAERI. Thermalhydraulic analysis with the assumption of CANFLEX-NU fuel loaded in Wolsong-1 was performed by using thermalhydraulic code, and the thermal margin and T/H compatibility of CANFLEX bundle with existing fuel for CANDU-6 reactor have been evaluated. (Author)

  8. The application of CANDU neutron economy for the annihilation of the minor actinides

    International Nuclear Information System (INIS)

    Dastur, Adi; Gagnon, Nathalie

    1995-01-01

    A strategically indispensable role, comparable to the one of operating with natural uranium, is proposed for CANDU as an incentive to ensure future CANDU sales in an environment where enrichment and reprocessing technology are globally available. Because of their high neutron economy, CANDU reactors can operate with minimal fissile content and consequently at high neutron flux. This is especially so in the absence of uranium, i.e. when transuranic actinides are used as fuel. The low fissile requirement and the on-power refuelling capability of CANDU can be exploited to achieve a once-through cycle for actinide annihilation. This avoids recycling and refabrication costs and provides relatively high annihilation rates. In addition, CANDUs ability to operate without uranium and extract energy from the minor actinides makes it the ultimate resource conserver and gives it a unique role in sustainable energy growth. (author)

  9. A design basis for the development of advanced CANDU control centres

    Energy Technology Data Exchange (ETDEWEB)

    Feher, M P; Davey, E C; Lupton, L R [Atomic Energy of Canada Ltd., Chalk River, ON (Canada)

    1996-12-31

    The basic design for current CANDU control centres was established in the early 1970`s. Plants constructed since then have, for the most part, retained the same basic design. Several factors have led to the need to re-examine CANDU control centre design for plants to be built beyond the year 2000. These factors include the changing roles and responsibilities for the operations staff, an improved understanding of operational issues associated with supervisory control, an improved understanding of human error in operational situations, the opportunity for improved plant performance through the introduction of new technologies, and marketing pressures. This paper describes the proposed design bases for the development of advanced control centres to be implemented in CANDU plants beyond the year 2000. Four areas have been defined covering design goals, design principles, operational bases, and plant functional bases. (author).

  10. A design basis for the development of advanced CANDU control centres

    International Nuclear Information System (INIS)

    Feher, M.P.; Davey, E.C.; Lupton, L.R.

    1995-01-01

    The basic design for current CANDU control centres was established in the early 1970's. Plants constructed since then have, for the most part, retained the same basic design. Several factors have led to the need to re-examine CANDU control centre design for plants to be built beyond the year 2000. These factors include the changing roles and responsibilities for the operations staff, an improved understanding of operational issues associated with supervisory control, an improved understanding of human error in operational situations, the opportunity for improved plant performance through the introduction of new technologies, and marketing pressures. This paper describes the proposed design bases for the development of advanced control centres to be implemented in CANDU plants beyond the year 2000. Four areas have been defined covering design goals, design principles, operational bases, and plant functional bases. (author)

  11. Distributed control system for CANDU 9 nuclear power plant

    International Nuclear Information System (INIS)

    Harber, J.E.; Kattan, M.K.; Macbeth, M.J.

    1996-01-01

    Canadian designed CANDU pressurized heavy water nuclear reactors have been world leaders in electrical power generation. The CANDU 9 project is AECL's next reactor design. The CANDU 9 plant monitoring, annunciation, and control functions are implemented in two evolutionary systems; the distributed control system (DCS) and the plant display system (PDS). The CDS implements most of the plant control functions in a single hardware platform. The DCS communicates with the PDS to provide the main operator interface and annunciation capabilities of the previous control computer designs along with human interface enhancements required in a modern control system. (author)

  12. Evolution of CANDU reactor design

    International Nuclear Information System (INIS)

    Pon, G.A.

    1978-08-01

    The CANDU (CANada Deuterium Uranium) design had its begin-ings in the early 1950's with the preliminary engineering studies that led to the 20 MW(e) NPD (Nuclear Power Demonstration) and the 200 MW(e) Douglas Point station . The next decade saw the first operation of both these stations and the commitment of the 2000 MW(e) Pickering and 3000 MW(e) Bruce plants. The present decade has witnessed the excellent performance of Pickering and Bruce and commitments to construct Gentilly-2, Cordoba, Pt. Lepreau, Wolsung, Pickering B, Bruce B and Darlington. In most cases, successive CANDU designs have meant an increase in plant output. Evolutionary developments have been made to fit the requirements of higher ratings and sizes, new regulations, better reliability and maintainability and lower costs. These changes, which are described system by system, have been introduced in the course of engineering parallel reactor projects with overlapping construction schedules -circumstances which ensure close contact with the practical realities of economics, manufacturing functions, construction activities and performance in commissioning. Features for one project furnished alternative concepts for others still on the drawing board and the experience gained in the first application yielded a sound basis for its re-use in succeeding projects. Thus the experiences gained in NPD, Douglas Point, Gentilly-1 and KANUPP have contributed to Pickering and Bruce, which in turn have contributed to the design of Gentilly-2. (author)

  13. CANDU nuclear power system

    International Nuclear Information System (INIS)

    1981-01-01

    This report provides a summary of the components that make up a CANDU reactor. Major emphasis is placed on the CANDU 600 MW(e) design. The reasons for CANDU's performance and the inherent safety of the system are also discussed

  14. Data base for a CANDU-PHW operating on a once-through, slightly enriched uranium cycle (AECL-6594)

    International Nuclear Information System (INIS)

    1979-07-01

    This report, prepared for INFCE, gives data for an extrapolated 1000 MW(e) CANDU-PHW design operating on a once-through fuel cycle with a feed fuel of slightly enriched uranium - 1.2 weight % U-235 in uranium. The effects of varying fuel enrichment, maximum channel power, and economic parameters are also discussed

  15. Qinshan CANDU commissioning - a successful partnership

    International Nuclear Information System (INIS)

    Alikhan, S.; Thomson, J.; Jun, G.; Guoyuan, J.

    2004-01-01

    The Qinshan CANDU Nuclear Power Plant consists of 2 x 728 MWe CANDU 6 units, built in Zhejiang Province, China, by the Third Qinshan Nuclear Power Company (TQNPC) as the owner and Atomic Energy of Canada Limited (AECL) as the main contractor. The Contract between China National Nuclear Corporation (CNNC) and AECL was signed in November 1996 and became effective on February 12, 1997 with scheduled completion dates of February 12, 2003 for Unit 1 and November 12, 2003 for Unit 2. Unit 1 was declared in-service on December 31, 2002, 43 days ahead of schedule and Unit 2 was declared in service on July 20, 2003, 115 days ahead of schedule. The successful partnership between AECL, Bechtel, Hitachi and TQNPC working as a team is the key to this success. Total commissioning period from first energization of the system service transformer to in-service for both units was 20.7 months, which is significantly better than the experience at other comparable CANDU 6 units. It has clearly demonstrated the benefits of building two units together, about 6 months apart, to achieve optimum utilization of resources already mobilized for the first unit; the second unit is commissioned with less than 40% of the effort required for the first unit. Since in-service to the end of March 2004, Unit 1 has operated at a gross capacity factor of 93% and Unit 2 at 82.5%, including loss of production for one month in August 2003 to repair the failure of turbine LP blades tie-wire. (author)

  16. Candu 6: versatile and practical fuel technology

    International Nuclear Information System (INIS)

    Hopwood, J. M.; Saroudis, J.

    2013-01-01

    CANDU can be deployed in Europe to reduce waste, save money for operating utilities (i.e. Nuclearelectrica) and introduce much more flexible fuel options. This paper provides an update on recent developments in the application of CANDU to important fuel cycle options. More specifically we report on recent developments in three key areas: China NUE uses both RU and DU, two waste products to make fuel. Test irradiations done, moving to full-core implementation, China - Thorium, UK - MOX. CANDU is a leading contender and most efficient practical solution. In the current context where nuclear power expansion remains under consideration for many countries as the primary greenhouse-gas-free energy option, the deployment of CANDU reactors for advanced fuel use provides important potential advantages, both on its own and in synergy with other elements of the global nuclear system. (authors)

  17. A safety concern related to CANDU moderator subcooling and status of KAERI moderator circulation test (MCT) experiments

    International Nuclear Information System (INIS)

    Rhee, Bo W.; Kim, Hyoung T.; Kim, Tongbeum; Im, Sunghyuk

    2015-01-01

    The flow inside the moderator tank of a CANDU-6 reactor during full power steady state operation has been suspected to be operating in the buoyancy/inertial driven mixed convection regime as illustrated in the middle figure. At some regions of the moderator tank where the buoyancy driven upward flow and the inertial momentum driven downward flows interface counter-currently, there exist some interface regions between these two flows like the middle one, and the local temperatures at these interface regions are known to oscillate with different amplitude at various fluctuation frequencies as shown. According to a numerical simulation of the moderator flow and temperature distribution at full power steady state carried out by previous researches showed that any small disturbances in the flow or temperature may initiate the system unstable and aggravate the asymmetric flow and temperature patterns. The tests at the 3-D Moderator Test Facility (MTF) that is a representative scaled-down of CANDU reactors, reproduced the expected and observed moderator behavior in the reactor as well as the local temperature fluctuations arising from the delicate balance of forced and buoyancy induced flow. This observation raised a safety concern as the local moderator temperature at some regions showed fluctuations with an amplitude that may jeopardize the safety margin, i.e. the difference between the available subcooling and the subcooling requirement. The scope of this paper is to review the basis of the safety concern related to this moderator subcooling and local temperature fluctuation and describe the current status of MCT erection and some of the experiments carried so far

  18. ACR-1000: Operator - based development

    International Nuclear Information System (INIS)

    Shalaby, B.; Alizadeh, A.

    2007-01-01

    Atomic Energy of Canada Limited (AECL) has adapted the successful features of CANDU * reactors to establish Generation III + Advanced CANDU Reactor T M (ACR T M) technology. The ACR-1000 T M nuclear power plant is an evolutionary product, starting with the strong base of CANDU reactor technology, coupled with thoroughly-demonstrated innovative features to enhance economics, safety, operability and maintainability. The ACR-1000 benefits from AECL's continuous-improvement approach to design, that enabled the traditional CANDU 6 product to compile an exceptional track record of on-time, on budget product delivery, and also reliable, high capacity-factor operation. The ACR-1000 engineering program has completed the basic plant design and has entered detailed pre-project engineering and formal safety analysis to prepare the preliminary (non-project-specific) safety case. The engineering program is strongly operator-based, and encompasses much more than traditional pre-project design elements. A team of utility-experienced operations and maintenance experts is embedded in the engineering team, to ensure that all design decisions, at the system and the component level, are taken with the owner-operator interest in mind. The design program emphasizes formal review of operating feedback, along with extensive operator participation in program management and execution. Design attention is paid to layout and access of equipment, to component and material selection, and to ensuring maximum ability for on-line maintenance. This enables the ACR-1000 to offer a three-year interval between scheduled maintenance outages, with a standard 21-day outage duration. SMART CANDU T M technology allows on-line monitoring and diagnostics to further enhance plant operation. Modules of the Advanced CANDU SMART technologies are already being back-fitted to current CANDU plants. As well as reviewing the ACR-1000 design features and their supporting background, the paper describes the status of

  19. Economics of CANDU

    International Nuclear Information System (INIS)

    McConnell, L.G.; Woodhead, L.W.

    1981-02-01

    The cost of producing electricity from CANDU reactors is discussed. The total unit energy cost of base-load electricity from CANDU reactors is compared with that of coal-fired plants in Ontario. In 1980 nuclear power was 8.41 m$/kW.h less costly for plants of similar size and vintage. Comparison of CANDU with pressurized water reactors indicated that the latter would be about 26 percent more costly in Ontario

  20. Simulation of LOCA power transients of CANDU6 by SCAN/RELAP-CANDU coupled code system

    International Nuclear Information System (INIS)

    Hong, In Seob; Kim, Chang Hyo; Hwang, Su Hyun; Kim, Man Woong; Chung, Bub Dong

    2004-01-01

    As can be seen in the standalone application of RELAP-CANDU for LOCA analysis of CANDU-PHWR, the system thermal-hydraulic code alone cannot predict the transient behavior accurately. Therefore, best estimate neutronics and system thermal-hydraulic coupled code system is necessary to describe the transient behavior with higher accuracy and reliability. The purpose of this research is to develop and test a coupled neutronics and thermal-hydraulics analysis code, SCAN (SNU CANDU-PHWR Neutronics) and RELAP-CANDU, for transient analysis of CANDU-PHWR's. For this purpose, a spatial kinetics calculation module of SCAN, a 3-D CANDU-PHWR neutronics design and analysis code, is dynamically coupled with RELAP-CANDU, the system thermal-hydraulic code for CANDU-PHWR. The performance of the coupled code system is examined by simulation of reactor power transients caused by a hypothetical Loss Of Coolant Accident (LOCA) in Wolsong units, which involves the insertion of positive void reactivity into the core in the course of transients. Specifically, a 40% Reactor Inlet Header (RIH) break LOCA was assumed for the test of the SCAN/RELAP-CANDU coupled code system analysis

  1. Development of a graphical animation interactive feature to assess MAAP-CANDU simulation results

    Energy Technology Data Exchange (ETDEWEB)

    Petoukhov, S.M., E-mail: sergei.petoukhov@cnl.ca [Canadian Nuclear Laboratories, Chalk River, ON (Canada); Karancevic, N., E-mail: karancevic@fauske.com [Fauske and Associates Inc. (FAI), Burr Ridge, IL (United States); Morreale, A.C., E-mail: andrew.morreale@cnl.ca [Canadian Nuclear Laboratories, Chalk River, ON (Canada); Paik, C.Y., E-mail: paik@fauske.com [Fauske and Associates Inc., Burr Ridge, IL (United States); Brown, M.J., E-mail: morgan.brown@cnl.ca [Canadian Nuclear Laboratories, Chalk River, ON (Canada); Cole, C., E-mail: christopher.cole@cnsc-ccsn.gc.ca [Canadian Nuclear Safety Commission, Ottawa, ON (Canada)

    2015-07-01

    MAAP-CANDU is an integrated severe accident analysis code for CANDU plant simulations that necessitates the assessment and post-processing of extensive amounts of information obtained from code run results. The MAAP-CANDU GRaphical Animation Package Extension (GRAPE) is a flexible, efficient, interactive and integrated visualization tool for analyzing plant behaviour during postulated accidents including accident management actions for single and multi-unit CANDU plants. GRAPE was developed by FAI in consultation with CNL (AECL) and CNSC from the FAI MAAP-GRAAPH code used in MAAP (LWR version). CNSC plans to use MAAP-CANDU and GRAPE as one of the tools in their Emergency Operations Centre.(author)

  2. Development of a graphical animation interactive feature to assess MAAP-CANDU simulation results

    International Nuclear Information System (INIS)

    Petoukhov, S.M.; Karancevic, N.; Morreale, A.C.; Paik, C.Y.; Brown, M.J.; Cole, C.

    2015-01-01

    MAAP-CANDU is an integrated severe accident analysis code for CANDU plant simulations that necessitates the assessment and post-processing of extensive amounts of information obtained from code run results. The MAAP-CANDU GRaphical Animation Package Extension (GRAPE) is a flexible, efficient, interactive and integrated visualization tool for analyzing plant behaviour during postulated accidents including accident management actions for single and multi-unit CANDU plants. GRAPE was developed by FAI in consultation with CNL (AECL) and CNSC from the FAI MAAP-GRAAPH code used in MAAP (LWR version). CNSC plans to use MAAP-CANDU and GRAPE as one of the tools in their Emergency Operations Centre.(author)

  3. CANDU lectures

    International Nuclear Information System (INIS)

    Rouben, B.

    1984-06-01

    This document is a compilation of notes prepared for two lectures given by the author in the winter of 1983 at the Institut de Genie Nucleaire, Ecole Polytechnique, Montreal. The first lecture gives a physical description of the CANDU reactor core: the nuclear lattice, the reactivity mechanisms, their functions and properties. This lecture also covers various aspects of reactor core physics and describes different calculational methods available. The second lecture studies the numerous facets of fuel management in CANDU reactors. The important variables in fuel management, and the rules guiding the refuelling strategy, are presented and illustrated by means of results obtained for the CANDU 600

  4. The CANDU man-machine interface and simulator training

    International Nuclear Information System (INIS)

    Hinchley, E.M.; Yanofsky, N.

    1982-09-01

    The most significant features of the man-machine interface for CANDU power stations are the extensive use of computer-driven colour graphics displays and the small number of manual controls. The man-machine interface in CANDU stations is designed to present the operator with concise, easy-to-understand information. Future developments in the use of computers in safety shutdown systems, and the use of data highway technologies in plant regulating systems will present special requirements and new opportunities in the application of human factors engineering to the control room. Good man-machine interaction depends on operator training as much as on control room design. In Canada computerized training simulators, which indicate plant response to operator action, are being introducted for operator training. Such simulators support training in normal operation of all plant systems and also in the fault management tasks following malfunctions

  5. Candu reactors with thorium fuel cycles

    International Nuclear Information System (INIS)

    Hopwood, J.M.; Fehrenbach, P.; Duffey, R.; Kuran, S.; Ivanco, M.; Dyck, G.R.; Chan, P.S.W.; Tyagi, A.K.; Mancuso, C.

    2006-01-01

    Over the last decade and a half AECL has established a strong record of delivering CANDU 6 nuclear power plants on time and at budget. Inherently flexible features of the CANDU type reactors, such as on-power fuelling, high neutron economy, fuel channel based heat transport system, simple fuel bundle configuration, two independent shut down systems, a cool moderator and a defence-in-depth based safety philosophy provides an evolutionary path to further improvements in design. The immediate milestone on this path is the Advanced CANDU ReactorTM** (ACRTM**), in the form of the ACR-1000TM**. This effort is being followed by the Super Critical Water Reactor (SCWR) design that will allow water-cooled reactors to attain high efficiencies by increasing the coolant temperature above 550 0 C. Adaptability of the CANDU design to different fuel cycles is another technology advantage that offers an additional avenue for design evolution. Thorium is one of the potential fuels for future reactors due to relative abundance, neutronics advantage as a fertile material in thermal reactors and proliferation resistance. The Thorium fuel cycle is also of interest to China, India, and Turkey due to local abundance that can ensure sustainable energy independence over the long term. AECL has performed an assessment of both CANDU 6 and ACR-1000 designs to identify systems, components, safety features and operational processes that may need to be modified to replace the NU or SEU fuel cycles with one based on Thorium. The paper reviews some of these requirements and the associated practical design solutions. These modifications can either be incorporated into the design prior to construction or, for currently operational reactors, during a refurbishment outage. In parallel with reactor modifications, various Thorium fuel cycles, either based on mixed bundles (homogeneous) or mixed channels (heterogeneous) have been assessed for technical and economic viability. Potential applications of a

  6. Advanced CANDU reactor development: a customer-driven program

    International Nuclear Information System (INIS)

    Hopwood, J.M.

    2005-01-01

    The Advanced CANDU Reactor (ACR) product development program is well under way. The development approach for the ACR is to ensure that all activities supporting readiness for the first ACR project are carded out in parallel, as parts of an integrated whole. In this way design engineering, licensing, development and testing, supply chain planning, construct ability and module strategy, and planning for commissioning and operations, all work in synergy with one another. Careful schedule management :ensures that program focus stays on critical path priorities.'This paper provides an overview of the program, with an emphasis on integration to ensure maximum project readiness, This program management approach is important now that AECL is participating as the reactor vendor in Dominion Energy's DOE-sponsored Combined Construction/Operating License (COL) program. Dominion Energy selected the ACR-700 as their reference reactor technology for purposes of demonstrating the COL process. AECL's development of the ACR is unique in that pre-licensing activities are being carded out parallel in the USA and Canada, via independent, but well-communicated programs. In the short term, these programs are major drivers of ACR development. The ACR design approach has been to optimize to achieve major design objectives: capital cost reduction, robust design with ample margins, proveness by using evolutionary change from existing :reference plants, design for ease :of operability. The ACR development program maintains these design objectives for each of the program elements: Design: .Carefully selected design innovations based on the SEU fuel/light water coolant:/heavy water moderator approach. Emphasis on lessons-learned review from operating experience and customer feedback Licensing: .Safety case based on strengths of existing CANDU plus benefits of optimised design Development and Test: Choice of materials, conditions to enable incremental testing building on existing CANDU and LWR

  7. Thermal-hydraulic interfacing code modules for CANDU reactors

    Energy Technology Data Exchange (ETDEWEB)

    Liu, W.S.; Gold, M.; Sills, H. [Ontario Hydro Nuclear, Toronto (Canada)] [and others

    1997-07-01

    The approach for CANDU reactor safety analysis in Ontario Hydro Nuclear (OHN) and Atomic Energy of Canada Limited (AECL) is presented. Reflecting the unique characteristics of CANDU reactors, the procedure of coupling the thermal-hydraulics, reactor physics and fuel channel/element codes in the safety analysis is described. The experience generated in the Canadian nuclear industry may be useful to other types of reactors in the areas of reactor safety analysis.

  8. Thermal-hydraulic interfacing code modules for CANDU reactors

    International Nuclear Information System (INIS)

    Liu, W.S.; Gold, M.; Sills, H.

    1997-01-01

    The approach for CANDU reactor safety analysis in Ontario Hydro Nuclear (OHN) and Atomic Energy of Canada Limited (AECL) is presented. Reflecting the unique characteristics of CANDU reactors, the procedure of coupling the thermal-hydraulics, reactor physics and fuel channel/element codes in the safety analysis is described. The experience generated in the Canadian nuclear industry may be useful to other types of reactors in the areas of reactor safety analysis

  9. Data base for a CANDU-PHW operating on the thorium cycle

    International Nuclear Information System (INIS)

    1979-07-01

    This report, prepared for INFCE, gives data for an extrapolated 1000 MW(e) CANDU-PHW design operating on various thorium cycles. In the reference cycle, the requirements for externally supplied fissile material are met using U-235, with the feed adjusted to provide a fuel burnup of approximately 30 000 MW.d/t(U). Two versions of the reference cycle are treated. In one, the U-235 is supplied in a highly enriched form (93 percent U-235 in uranium); in the other, the U-235 is supplied at a lower enrichment, such that the uranium present in the feed fuel is 'denatured'. The effects of varying the fuel burnup and the recycle delay time are discussed. Data are also given for thorium cycles using plutonium instead of U-235 to meet requirements for externally-supplied fissile material. The special case of 'self-sufficient equilibrium thorium cycles', which require no external source of fissile material for equilibrium operation, is also treated. (author)

  10. The Canadian R and D program targeted at CANDU reactors

    International Nuclear Information System (INIS)

    Moeck, E.O.

    1988-01-01

    CANDU reactors produce electricity cheaply and reliably, with miniscule risk to the population and minimal impact on the environment. About half of Ontario's electricity and a third of New Brunswick's are generated by CANDU power plants. Hydro Quebec and utilities in Argentina, India, Pakistan, and the Republic of Korea also successfully operate CANDU reactors. Romania will soon join their ranks. The proven record of excellent performance of CANDUs is due in part to the first objective of the vigorous R and D program: namely, to sustain and improve existing CANDU power-plant technology. The second objective is to develop improved nuclear power plants that will remain competitive compared with alternative energy supplies. The third objective is to continue to improve our understanding of the processes underlying reactor safety and develop improved technology to mitigate the consequences of upset conditions. These three objectives are addressed by individual R and D programs in the areas of CANDU fuel channels, reduced operating costs, reduced capital costs, reactor safety research, and IAEA safeguards. The work is carried out mainly at three centres of Atomic Energy of Canada Limited--the Chalk River Nuclear Laboratories, the Whiteshell Nuclear Research Establishment, and the Sheridan Park Engineering Laboratories--and at Ontario Hydro's Research Laboratories. Canadian universities, consultants, manufacturers, and suppliers also provide expertise in their areas of specialization

  11. Development of advanced CANDU PHWR -Development of the advanced CANDU technology-

    International Nuclear Information System (INIS)

    Seok, Ho Cheon; Na, Yeong Hwan; Seok, Soo Dong; Lee, Bo Uk; Kwak, Ho Sang; Kim, Bong Ki; Kim, Seok Nam; Min, Byeong Joo; Park, Jong Ryunl; Shin, Jeong Cheol; Lee, Kyeong Ho; Lee, Dae Hee; Lee, Deuk Soo; Lee, Yeong Uk; Lee, Jeong Yang; Jwon, Jong Seon; Jwon, Chang Joon; Ji, Yong Kwan; Han, Ki Nam; Kim, Kang Soo; Kim, Dae Jin; Kim, Seon Cheol; Kim, Seong Hak; Kim, Yeon Seung; Kim, Yun Jae; Kim, Jeong Kyu; Kim, Jeong Taek; Kim, Hang Bae; Na, Bok Kyun; Namgung, In; Moon, Ki Hwan; Park, Keun Ok; Shon, Ki Chang; Song, In Ho; Shin, Ji Tae; Yeo, Ji Won; Oh, In Seok; Jang, Ik Ho; Jeong, Dae Won; Jeong, Yong Hwan; Ha, Jae Hong; Ha, Jeong Koo; Hong, Hyeong Pyo; Hwang, Jeong Ki

    1994-07-01

    The target of this project is to assess the feasibility of improving PHWR and to establish the parameter of the improved concept and requirements for developing it. To set up the requirements for the Improved Pressurized Heavy Water Reactor: (1) Design requirements of PHWR main systems and Safety Design Regulatory Requirements for Safety Related System i.e. Reactor Shutdown System, Emergency Core Cooling System and Containment System were prepared. (2) Licensing Basis Documents were summarized and Safety Analysis Regulatory. Requirements were reviewed and analyzed. To estimate the feasibility of improving PHWR and to establish the main parameters of the concept of new PHWR in future: (1) technical level/developing trend of PHWR in Korea through Wolsong 2, 3 and 4 design experience and Technical Transfer Program was investigated to analyze the state of basic technology and PHWR improvement potential. (2) CANDU 6 design improvement tendency, CANDU 3 design concept and CANDU 9 development state in other country was analyzed. (3) design improvement items to apply to the reactors after Wolsong 2, 3 and 4 were selected and Plant Design Requirements and Conceptual Design Description were prepared and the viability of improved HWR was estimated by analyzing economics, performance and safety. (4) PHWR technology improving research and development plan was established and international joint study initiated for main design improvement items

  12. The CANDU 9 fuel transfer system

    International Nuclear Information System (INIS)

    Keszthelyi, Z.G.; Morikawa, D.T.

    1996-01-01

    The CANDU 9 fuel transfer system is based on the CANDU 6 and the Ontario Hydro Darlington NGD designs, modified to suit the CANDU 9 requirements. The CANDU 9 new fuel transfer system is very similar to the CANDU 6, with modifications to allow new fuel loading from outside containment, similar to Darlington. The CANDU 9 irradiated fuel transfer system is based on the Darlington irradiated fuel transfer system, with modifications to meet the more stringent containment requirements, improve performance, and match station layout. (author). 2 refs., 6 figs

  13. The CANDU 9 fuel transfer system

    Energy Technology Data Exchange (ETDEWEB)

    Keszthelyi, Z G [Canadian General Electric Co. Ltd., Peterborough, ON (Canada); Morikawa, D T [Atomic Energy of Canada Ltd., Mississauga, ON (Canada)

    1997-12-31

    The CANDU 9 fuel transfer system is based on the CANDU 6 and the Ontario Hydro Darlington NGD designs, modified to suit the CANDU 9 requirements. The CANDU 9 new fuel transfer system is very similar to the CANDU 6, with modifications to allow new fuel loading from outside containment, similar to Darlington. The CANDU 9 irradiated fuel transfer system is based on the Darlington irradiated fuel transfer system, with modifications to meet the more stringent containment requirements, improve performance, and match station layout. (author). 2 refs., 6 figs.

  14. Team CANDU : ready for the marketplace

    International Nuclear Information System (INIS)

    Howieson, J.Q.

    2007-01-01

    This paper outlines the partnership between AECL and a number of leading global nuclear suppliers to market the Candu power reactor. The mission of the CANDU team is to develop market opportunities for CANDU technology and deliver successful CANDU projects

  15. Modularized construction, structural design and analysis of CANDU 3 plant

    Energy Technology Data Exchange (ETDEWEB)

    Biswas, J K; Wollin, S; Selvadurai, S; Saudy, A M [Atomic Energy of Canada Ltd., Saskatoon, SK (Canada)

    1996-12-31

    CANDU 3 is rated at 450 MW electric, and is a smaller and advanced version of CANDU reactors successfully operating in Canada and abroad. The design uses modularization to minimize the construction schedule and thereby reduce cost. The paper (which is published only as a long summary), deals with the concept of modularization, and with stress analysis of the various civil structures.

  16. Modularized construction, structural design and analysis of CANDU 3 plant

    International Nuclear Information System (INIS)

    Biswas, J.K.; Wollin, S.; Selvadurai, S.; Saudy, A.M.

    1995-01-01

    CANDU 3 is rated at 450 MW electric, and is a smaller and advanced version of CANDU reactors successfully operating in Canada and abroad. The design uses modularization to minimize the construction schedule and thereby reduce cost. The paper (which is published only as a long summary), deals with the concept of modularization, and with stress analysis of the various civil structures

  17. Development of CANDU 6 Primary Heat Transport System Modeling Program

    International Nuclear Information System (INIS)

    Seo, Hyung-beom; Kim, Sung-min; Park, Joong-woo; Kim, Kwang-su; Ko, Dae-hack; Han, Bong-seob

    2007-01-01

    NUCIRC is a steady-state thermal-hydraulic code used for design and performance analyses of CANDU Heat Transport System. The code is used to build PHT model in Wolsong NPP and to calculate channel flow distribution. Wolsong NPP has to calculate channel flow distribution and quality of coolant at the ROH header after every outage by OPP (Operating Policy and Principal). PHT modeling work is time consuming which need a lot of operation experience and specialty. It is very difficult to build PHT model as plant operator in two weeks which is obligate for plant operation after every outage. That is why Wolsong NPP develop NUMODEL (NUcirc MODELing) with many-years experience and a know-how of using NUCIRC code. NUMODEL is computer program which is used to create PHT model based on utilizing NUCIRC code

  18. Role of water lubricated bearings in Candu reactors

    International Nuclear Information System (INIS)

    Kumar, Ashok N.

    1999-01-01

    During the twentieth century a great emphasis was placed in understanding and defining the operating regime of oil and grease lubricated components. Major advances have been made through elastohydrodynamic lubrication theory in the quantifying the design life of heavily loaded components such as rolling element bearings and gears. Detailed guidelines for the design of oil and grease lubricated components are widely available and are being applied to the successful design of these components. However similar guidelines for water lubricated components are either not available or not well documented. It is often forgotten that the water was used as a lubricant in several components as far back as 1884 B.C. During the twentieth century the water lubricated components continued to play a major role in some high technology industries such as in the power generation plants. In CANDU nuclear reactors water lubrication of several critical components always occupied a pride place and in most cases the only practical mode of lubrication of several critical components always occupied a pride place and in most cases the only practical mode of lubrication. This paper presents some examples of the major water lubricated components in a CANDU reactors. Major part of the paper is focused on presenting an example of successful operating history of water lubricated bearings used in the HT pumps are presented. Both types of bearings have been qualified by tests for operation under normal as well as under more severe postulated condition of loss-of-coolant-accident (LOCA). These bearings have been designed to operate for the 30 years in the existing CANDU 6 (600 MW) reactors. However for the next generation of CANDU 6 reactors which go into service in the year 2003, the HT pump bearing life has been extended to 40 years. (author)

  19. Aging of elastomers in CANDU pressure boundary service

    International Nuclear Information System (INIS)

    VanBerlo, C.; Leidner, J.

    1987-09-01

    This report describes the properties and aging of elastomers, and examines the performance of major elastomeric components in CANDU pressure boundary service. The components examined are vacuum building roof seals, pressure relief duct seals, airlock door seals, fuelling machine hoses, and cable penetrations. For each of these components, the design requirements, technical specifications and component testing procedures are compared with applicable standards. Information on actual and recommended monitoring and maintenance methods is presented. Operational and environmental stressors are identified. Component failure modes, causes and frequencies are described, as well as the remedial action taken. Many different elastomers are used in CANDU plants, for many different applications. Standards and manufacturers' recommendations are not consistent and may vary from one component to another. Accordingly, the monitoring, maintenance and replacement practices tend to vary from one application to another, and may also be different at different stations. Recommendations are given in this report for improved monitoring and maintenance, in an attempt to provide more consistency in approach. A summary of some experiences with elastomers from non-Canadian sources is contained in the last section. 125 refs

  20. AECL's advanced CANDU reactor - the ACR

    International Nuclear Information System (INIS)

    Alizadeh, Ala; Allsop, Peter; Hedges, Ken; Hopwood, Jerry; Yu, Stephen

    2003-01-01

    The ACR, the next generation CANDU design, represents the next step in development of the CANDU family of designs. AECL has achieved significant incremental improvements to the mid-size CANDU 6 nuclear power plant through successive projects, both in design and in project delivery. Building on this knowledge base, AECL is continuing to adapt the CANDU design to develop the ACR. This paper summarizes the ACR design features, which include major improvements in economics, inherent safety characteristics, performance and construction methods. Aimed at producing electrical power at a capital cost significantly less than that of the current reactor designs, the ACR is an evolutionary design based on the very successful CANDU 6 reactor. The new ACR product is specifically designed to produce power at a cost competitive with other forms of power generation while achieving short construction times, improved safety, international licensability, high investor returns, and low investor risk. It achieves these targets by taking advantage of the latest advances in both pressure-tube and pressure-vessel reactor technologies and experience. The flexibility and development potential of the fuel channel approach also enables designs to be developed that address priorities identified in international long-term specification programs such as the US Department of Energy (DOE) sponsored Generation IV program and IAEA hosted INPRO program. ACR-700 can be built in 36 months with a 48 month project duration, and deliver a lifetime capacity factor in excess of 90%. Overall, the ACR design represents a balance of proven design basis and innovations to give step improvements in safety, reliability and economics. The ACR development program, now well into the detail design stage, includes parallel formal licensing in the USA and Canada. Based on the status of the ACR design and AECL's on-going experience delivering reactor projects on-time and on-budget, the first ACR could be in service by

  1. Improving the service life and performance of CANDU fuel channels

    International Nuclear Information System (INIS)

    Coleman, C.E.; Cheadle, B.A.; Causey, A.R.; Doubt, G.L.; Fong, R.W.L.; Venkatapathi, S.

    1996-03-01

    The development objective for CANDU fuel channels is to produce a design that can operate for 40 years at 90% capacity. Steady progress toward this objective is being made. The factors that determine the life of a CANDU fuel channel are reviewed and the processes necessary to achieve the objectives are identified. Performance of future fuel channels will be enhanced by reduced operating costs and increased safety margins to postulated accident conditions compared with those for current channels. The approaches to these issues are discussed briefly in this report. (author)

  2. Thermo-Economic Assessment of Advanced,High-Temperature CANDU Reactors

    International Nuclear Information System (INIS)

    Spinks, Norman J.; Pontikakis, Nikos; Duffey, Romney B.

    2002-01-01

    Research underway on the advanced CANDU examines new, innovative, reactor concepts with the aim of significant cost reduction and resource sustainability through improved thermodynamic efficiency and plant simplification. The so-called CANDU-X concept retains the key elements of the current CANDU designs, including heavy-water moderator that provides a passive heat sink and horizontal pressure tubes. Improvement in thermodynamic efficiency is sought via substantial increases in both pressure and temperature of the reactor coolant. Following on from the new Next Generation (NG) CANDU, which is ready for markets in 2005 and beyond, the reactor coolant is chosen to be light water but at supercritical operating conditions. Two different temperature regimes are being studied, Mark 1 and Mark 2, based respectively on continued use of zirconium or on stainless-steel-based fuel cladding. Three distinct cycle options have been proposed for Mark 1: the High-Pressure Steam Generator (HPSG) cycle, the Dual cycle, and the Direct cycle. For Mark 2, the focus is on simplification via a Direct cycle. This paper presents comparative thermo-economic assessments of the CANDU-X cycle options, with the ultimate goal of ascertaining which particular cycle option is the best overall in terms of thermodynamics and economics. A similar assessment was already performed for the NG CANDU. The economic analyses entail obtaining cost estimates of major plant components, such as heat exchangers, turbines and pumps. (authors)

  3. CANDU fuel behaviour under LOCA conditions

    International Nuclear Information System (INIS)

    Kohn, E.

    1989-07-01

    This report summarizes the current understanding of CANDU fuel-element behaviour under loss-of-coolant (LOCA) accidents. It focuses on a key in-reactor verification experiment conducted at Idaho National Engineering Laboratory (INEL) and on three Canadian in-reactor tests. The in-reactor data, and the considerable body of supporting information developed from out-reactor tests, support the general conclusion that CANDU fuel behaviour during LOCA transients is well understood. Four elements of 37-element CANDU fuel-bundle design were tested under conditions typical of a large-break LOCA blowdown in a CANDU reactor. The purpose of the test was to confirm our current understanding of fuel behaviour under loss-of-coolant accident blowdown conditions. The test also provided data for comparison with predictions made with the steady-state and transient fuel-element performance codes ELESIM and ELOCA. Key components of typical LOCA transients were incorporated in the test: namely, a rapid depressurization rate of the hot coolant, a simultaneous power increase before decreasing to decay values (a power pulse), and prototype fuel element under pre-transient power and burnup conditions. The test was successfully completed in the Power Burst Facility (PBF) reactor at INEL under contract to Ontario Hydro and AECL. The three CANDU Owners Group LOCA tests performed at Chalk River Nuclear Laboratories measured both the thermal-mechanical response and fission-gas release resulting from exposure to a LOCA transient. Results from these three tests provided further confirmation that the behaviour of the fuel under LOCA conditions is understood

  4. The relationship between natural uranium and advanced fuel cycles in CANDU reactors

    International Nuclear Information System (INIS)

    Lane, A.D.; McDonnell, F.N.; Griffiths, J.

    1988-11-01

    CANDU is the most uranium-economic type of thermal power reactor, and is the only type used in Canada. CANDU reactors consume approximately 15% of Canadian uranium production and support a fuel service industry valued at ∼$250 M/a. In addition to their once-through, natural-uranium fuel cycle, CANDU reactors are capable of operating with slightly-enriched uranium (SEU), uranium-plutonium and thorium cycles, more efficiently than other reactors. Only SEU is economically attractive in Canada now, but the other cycles are of interest to countries without indigenous fuel resources. A program is underway to establish the fuel technologies necessary for the use of SEU and the other fuel cycles in CANDU reactors. 22 refs

  5. Sensitivity Study for Feed and Bleed Operation for Domestic CANDU Nuclear Power Plants

    Energy Technology Data Exchange (ETDEWEB)

    Kim, K. S; Kim, B. S.; Yoo, H. K.; Kim, H. J. [Atomic Creative Technology Co., Daejeon (Korea, Republic of); Whang, S. W. [Korea Hydro and Nuclear Power Co., Daejeon (Korea, Republic of)

    2016-05-15

    The purpose of this paper is to evaluate the effects of the feed and bleed operation using DCT(Degassing Condenser Tank) over-pressure protection valves when LOCL4 with LOCL3 occurs during LPSD mid-loop operation. The CDF(Core Damage Frequency) of Level-1 Internal Event for Wolsong NPP Unit 1 during LPSD POS5A/5B accounts for about 89.08%(POS5A: 30.04%, POS5B: 59.04%) of the total CDF. For Wolsong NPP Unit 1 LPSD External Event, seismic analysis is excluded from this study because it is PSA-based SMA(Seismic Margin Assessment based Probabilistic Safety Assessment). For the domestic CANDU NPP, the feed and bleed operation using DCT over-pressure protection valves has been incorporated as an additional measure to mitigate the consequences during LPSD mid-loop operation. Since LOCL4 with LOCL3 is considered to be the event with highest frequency among all initial events, the effect of the feed and bleed operation on the safety of Nuclear Power Plant has been evaluated using PSA methodology.

  6. Computer based core monitoring system for an operating CANDU reactor

    International Nuclear Information System (INIS)

    Yoon, Moon Young; Kwon, O Hwan; Kim, Kyung Hwa; Yeom, Choong Sub

    2004-01-01

    The research was performed to develop a CANDU-6 Core Monitoring System(CCMS) that enables operators to have efficient core management by monitoring core power distribution, burnup distribution, and the other important core variables and managing the past core history for Wolsong nuclear power plant unit 1. The CCMS uses Reactor Fueling Simulation Program(RFSP, developed by AECL) for continuous core calculation by integrating the algorithm and assumptions validated and uses the information taken from Digital Control Computer(DCC) for the purpose of producing basic input data. The CCMS has two modules; CCMS server program and CCMS client program. The CCMS server program performs automatic and continuous core calculation and manages overall output controlled by DataBase Management System. The CCMS client program enables users to monitor current and past core status in the predefined GUI(Graphic-User Interface) environment. For the purpose of verifying the effectiveness of CCMS, we compared field-test data with the data used for Wolsong unit 1 operation. In the verification the mean percent differences of both cases were the same(0.008%), which showed that the CCMS could monitor core behaviors well

  7. Comparison of neutron parameters between a CANDU and ACR reactors; Comparacao de parametros neutronicos entre um reator CANDU e um ACR

    Energy Technology Data Exchange (ETDEWEB)

    Dias, Gabriel H.P.; Silva, Clarysson A.M. da; Pereira, Claubia, E-mail: gabrielhpd@yahoo.com.br, E-mail: clarysson@nuclear.ufmg.br, E-mail: claubia@nuclear.ufmg.br [Universidade Federal de Minas Gerais (UFMG), Belo Horizonte, MG (Brazil). Departamento de Engenharia Nuclear

    2017-11-01

    CANDU (Canadian Deuterium Uranium) is a type of reactor that uses heavy water (D{sub 2}O) as a moderator and as a refrigerant. Despite having chemical characteristics similar to light water (H{sub 2}O), heavy water has a high moderation ratio for neutrons. This feature enables CANDU to use natural uranium as fuel. However, research has evaluated the possibility of using H{sub 2}O as a refrigerant and D{sub 2}O as a moderator aiming at reducing the volume of heavy water. Such changes would imply the use of lightly enriched uranium due to the presence of H{sub 2}O. In this context, the concept of ACR (Advanced CANDU Reactor) has been developed. This reactor has an innovative design which combines of the current CANDU with the characteristics of PWR (Pressurized Water Reactor) type reactors. Studies by AECL (Atomic Energy Canada Limited) show that compared to CANDU, the ACR presents a cost reduction in construction, improved firing performance, improved operation safety and longer life. The present work aims to evaluate, in steady state, some of the main neutron parameters of CANDU-6 and ACR-1000. The MCNPX 2.6.0 code (Monte Carlo N-Particle eXtended -version 2.6.0) was used to simulate such types of reactors. The results show that the models configured in the MCNPX adequately reproduce the neutron behavior of the studied reactors. These models may be used in future work for analysis of fuel burn and evolution.

  8. Explaining the absence of Co-58 radiation fields around CANDU reactor primary circuit

    International Nuclear Information System (INIS)

    Burrill, K.A.; Guzonas, D.A.

    2002-01-01

    Radiation fields from Co-58 are rarely detected in CANDU plants. For example, Ge(Li) surveys of the Inconel 600 steam generators at some CANDU plants may show radiation attributed to Co-58 only early in plant life, and most artefacts removed from the primary circuit later in plant operation show no Co-58 present. However, Pressurized Water Reactor plants experience relatively large fields from Co-58 on their isothermal piping, e.g., steam generator channel head, and steam generators tube sampling programs do show deposits in the tubes with significant Co-58 compared to other radionuclides such as Co-60. CANDU reactors have high concentrations of dissolved iron due to the extensive use of carbon steel for the isothermal piping, e.g., feeders, headers, and steam generator channel heads. A dissolved iron transport diagram that was proposed recently for the primary circuit of CANDU plants has been validated by comparison of predicted deposit weights with plant deposit data from various components. One feature of the diagram is dissolved iron precipitation inside the steam generators tubes. An hypothesis is advanced here in which precipitating dissolved iron is proposed to occlude dissolved nickel. This removal mechanism may prevent the solubility of dissolved nickel from being exceeded anywhere around the primary circuit. In particular, this mechanism could avoid NiO precipitation in the core and the generation of large quantities of Co-58. Using this mechanism along with the known solubility behaviour of NiO with temperature, a dissolved nickel transport diagram has been proposed for CANDU plants. (authors)

  9. Material control and accounting at a CANDU reactor: the instrumented safeguards scheme

    International Nuclear Information System (INIS)

    Stirling, A.J.; Payne, E.

    1985-01-01

    While CANDU reactors differ from LWRs quite markedly in the way they operate, the principles of materials accounting and safeguards are equally applicable. Indeed, since CANDU fuel is not reprocessed, the relatively simple procedure of item accounting is sufficient for CANDUs. However, on-power refueling means that automatic item counting is needed to independently confirm operator records. Surveillance and sealing techniques for spent fuel are needed for a practical system. The equipment developed has allowed the IAEA to apply safeguards at reasonable cost and with minimal interference to the utility operating the station

  10. The ageing of CANDU steam generator due to localized corrosion

    International Nuclear Information System (INIS)

    Lucan, D.; Fulger, M.; Jinescu, Ghe.

    2001-01-01

    The principal types of corrosion are presented which can occur in CANDU steam generator. There are also presented the operation conditions, the specifications referring to the water chemistry and the construction materials of Steam Generator, the factors that have a great influence on the corrosion behaviour during the whole exploitation period of this equipment. The most important elements of CANDU Steam Generator ageing management program are also discussed. (R. P.)

  11. Design, construction and operation of Ontario Hydro's CANDU plants

    International Nuclear Information System (INIS)

    Campbell, P.G.

    1981-06-01

    Ontario Hydro has been producing electricity commercially from nuclear power since 1968, using CANDU reactors which have proved enormously successful. The 206-MW Douglas Point station, nearly 10 times larger than the first Canadian power reactor, NPD-2, resulted from a cooperative effort between Atomic Energy of Canada Ltd., the provincial government of Ontario, and Ontario Hydro. This approach led to a basic working relationship between the parties, with Ontario Hydro acting as project manager and builder, and AECL acting as consultant with respect to the nuclear components. Before Douglas Point was fully commissioned Ontario Hydro was ready to commit itself to more nuclear stations, and work was started on the four-unit Pickering nuclear generating station. Multi-unit stations were adopted to achieve economies of scale, and the concept has been retained for all subsequent nuclear power plants constructed in the province. The organization of Ontario Hydro's project management, construction, and operation of nuclear generating stations is described. Performance of the existing stations and cost of the power they produce have been entirely acceptable

  12. Thermal Hydraulic Assessment for Loss of SDCS Event During the Outage of CANDU Reactor

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Jonghyun [Gnest, Inc. Taejon (Korea, Republic of); Lee, Kwangho; Oh, Haechol; Jun, Hwangyong [KEPRI, Taejon (Korea, Republic of)

    2006-07-01

    During the outage(overhaul) of the nuclear power plant, there are several operating states other than the full power state, that is 'Hot-Zero Power', 'Depressurized-Cooldown', and 'Partially Drained'. Until now safety assessment has not been done much for this operating state of CANDU type reactor worldwide. For the accuracy and confidence of PSA for the CANDU outage, the safety analysis is necessary. At the first stage, we analyzed the thermal hydraulic characteristics and safety of the postulated event of loss of shutdown cooling system (SDCS) during the partially drained state which is the longest one in the middle of outage period. As an analysis tool, this study uses the best estimate thermal hydraulic code, RELAP5/CANDU which was modified according to the CANDU specific characteristics and based on RELAP5.Mod3.

  13. An optimum fuel management method based on CANDU in-core detector readings

    International Nuclear Information System (INIS)

    Jeong, Chang Joon; Choi, Hang Bok

    2001-01-01

    In this study, a new optimal fuel management method is developed for a CANDU 600 MWe (CANDU-6) reactor. At first, an efficient power mapping method has been developed, which provides an accurate core status of an operating CANDU reactor. Secondly, an optimum refueling channel selection method has been developed by an optimization theory. For the power mapping method, the measured detector readings are used as boundary conditions of the diffusion theory calculation with the Kalman filtering (DIKAL) method. The performance of the DIKAL method was assessed for various core states and applied to the calculation of power and flux distribution in the CANDU 6 reactor. Sensitivity studies have shown that DIKAL method is insensitive to the detector random and systematic errors. An optimal refueling simulation method (OPTIMA), practically applicable to a CANDU 6 reactor, has also been developed. The objective of the optimization is to reproduce the reference core performance during refueling simulation, while satisfying the operation limits of channel and bundle powers. The optimization process consists of two stages: i) elimination of candidate refueling channels by several constraints and ii) selection of refueling channels by a direct search method that uses sensitivity coefficients of channel power generated for the reference core. The elimination process sorts out an appropriate number of fuel channels suitable for refueling, considering the channel power, bundle power and fuel burnup. The optimum refueling channels are then selected such that the difference of power distribution from the reference is minimized. In order to demonstrate the applicability of the overall fuel management methodology developed in this study, the DIKAL-OPTIMA method was applied to Wolsong-3 reactor refueling simulation, which is a typical CANDU-6 reactor. The results of refueling simulation have shown that the method can be efficiently used for the performance analysis of the operating

  14. An optimum fuel management method based on CANDU in-core detector readings

    Energy Technology Data Exchange (ETDEWEB)

    Jeong, Chang Joon; Choi, Hang Bok

    2001-01-01

    In this study, a new optimal fuel management method is developed for a CANDU 600 MWe (CANDU-6) reactor. At first, an efficient power mapping method has been developed, which provides an accurate core status of an operating CANDU reactor. Secondly, an optimum refueling channel selection method has been developed by an optimization theory. For the power mapping method, the measured detector readings are used as boundary conditions of the diffusion theory calculation with the Kalman filtering (DIKAL) method. The performance of the DIKAL method was assessed for various core states and applied to the calculation of power and flux distribution in the CANDU 6 reactor. Sensitivity studies have shown that DIKAL method is insensitive to the detector random and systematic errors. An optimal refueling simulation method (OPTIMA), practically applicable to a CANDU 6 reactor, has also been developed. The objective of the optimization is to reproduce the reference core performance during refueling simulation, while satisfying the operation limits of channel and bundle powers. The optimization process consists of two stages: i) elimination of candidate refueling channels by several constraints and ii) selection of refueling channels by a direct search method that uses sensitivity coefficients of channel power generated for the reference core. The elimination process sorts out an appropriate number of fuel channels suitable for refueling, considering the channel power, bundle power and fuel burnup. The optimum refueling channels are then selected such that the difference of power distribution from the reference is minimized. In order to demonstrate the applicability of the overall fuel management methodology developed in this study, the DIKAL-OPTIMA method was applied to Wolsong-3 reactor refueling simulation, which is a typical CANDU-6 reactor. The results of refueling simulation have shown that the method can be efficiently used for the performance analysis of the operating

  15. Improving the service life and performance of CANDU fuel channels

    International Nuclear Information System (INIS)

    Causey, A.R.; Cheadle, B.A.; Coleman, C.E.; Price, E.G.

    1996-02-01

    The development objective for CANDU fuel channels is to produce a design that can operate for 40 years at 90% capacity. Steady progress toward this objective is being made. The factors that determine the life of a CANDU fuel channel are reviewed and the processes necessary to achieve the objectives identified. Performance of future fuel channels will be enhanced by reduced operating costs, increased safety margins to postulated accident conditions, and reduced retubing costs compared with those for current channels. The approaches to these issues are discussed briefly in this report. (author). 14 refs., 1 tab., 8 figs

  16. Incentives for improvement of CANDU

    International Nuclear Information System (INIS)

    Hart, R.S.; Dunn, J.T.; Finlay, R.B.

    1988-12-01

    CANDU is a relatively young technology which has demonstrated many achievements as an electrical power generation system. These achievements include an unsurpassed safety record, high annual and lifetime capacity factors, low electricity cost and a broad range of other performance strengths which together indicate that the CANDU technology is fundamentally sound. Known capabilities not yet fully exploited, such as advanced fuel cycle options, indicate that CANDU technology will continue to pay strong dividends on research, development and design investment. This provides a strong incentive for the improvement of CANDU on a continuing basis

  17. Impact of aging and material structure on CANDU plant performance

    International Nuclear Information System (INIS)

    Nadeau, E.; Ballyk, J.; Ghalavand, N.

    2011-01-01

    In-service behaviour of pressure tubes is a key factor in the assessment of safety margins during plant operation. Pressure tube deformation (diametral expansion) affects fuel bundle dry out characteristics resulting in reduced margin to trip for some events. Pressure tube aging mechanisms also erode design margins on fuel channels or interfacing reactor components. The degradation mechanisms of interest are primarily deformation, loss of fracture resistance and hydrogen ingress. CANDU (CANada Deuterium Uranium, a registered trademark of the Atomic Energy of Canada Limited used under exclusive licence by Candu Energy Inc.) owners and operators need to maximize plant capacity factor and meet or exceed the reactor design life targets while maintaining safety margins. The degradation of pressure tube material and geometry are characterized through a program of inspection, material surveillance and assessment and need to be managed to optimize plant performance. Candu is improving pressure tubes installed in new build and life extension projects. Improvements include changes designed to reduce or mitigate the impact of pressure tube elongation and diametral expansion rates, improvement of pressure tube fracture properties, and reduction of the implications of hydrogen ingress. In addition, Candu provides an extensive array of engineering services designed to assess the condition of pressure tubes and address the impact of pressure tube degradation on safety margins and plant performance. These services include periodic and in-service inspection and material surveillance of pressure tubes and deterministic and probabilistic assessment of pressure tube fitness for service to applicable standards. Activities designed to mitigate the impact of pressure tube deformation on safety margins include steam generator cleaning, which improves trip margins, and trip design assessment to optimize reactor trip set points restoring safety and operating margins. This paper provides an

  18. Cobalt-60 production in CANDU power reactors

    International Nuclear Information System (INIS)

    Slack, J.; Norton, J.L.; Malkoske, G.R.

    2003-01-01

    MDS Nordion has been supplying cobalt-60 sources to industry for industrial and medical purposes since 1946. These cobalt-60 sources are used in many market and product segments. The major application is in the health care industry where irradiators are used to sterilize single use medical products. These irradiators are designed and built by MDS Nordion and are used by manufacturers of surgical kits, gloves, gowns, drapes and other medical products. The irradiator is a large shielded room with a storage pool for the cobalt-60 sources. The medical products are circulated through the shielded room and exposed to the cobalt-60 sources. This treatment sterilizes the medical products which can then be shipped to hospitals for immediate use. Other applications for this irradiation technology include sanitisation of cosmetics, microbial reduction of pharmaceutical raw materials and food irradiation. The cobalt-60 sources are manufactured by MDS Nordion in their Cobalt Operations Facility in Kanata. More than 75,000 cobalt-60 sources for use in irradiators have been manufactured by MDS Nordion. The cobalt-60 sources are double encapsulated in stainless steel capsules, seal welded and helium leak tested. Each source may contain up to 14,000 curies. These sources are shipped to over 170 industrial irradiators around the world. This paper will focus on the MDS Nordion proprietary technology used to produce the cobalt-60 isotope in CANDU reactors. Almost 55 years ago MDS Nordion and Atomic Energy of Canada developed the process for manufacturing cobalt-60 at the Chalk River Labs, in Ontario, Canada. A cobalt-59 target was introduced into a research reactor where the cobalt-59 atom absorbed one neutron to become cobalt-60. Once the cobalt-60 material was removed from the research reactor it was encapsulated in stainless steel and seal welded using a Tungsten Inert Gas weld. The first cobalt-60 sources manufactured using material from the Chalk River Labs were used in cancer

  19. The CANTEACH project: preserving CANDU technical knowledge

    International Nuclear Information System (INIS)

    Garland, B.; Kosarenko, Y.; Meneley, D.

    2003-01-01

    Almost sixty years have passed since the nuclear energy venture began in Canada. Fifty years have passed since the founding of AECL. Tens of thousands of dedicated people have forged a new and successful primary energy supply. CANDU technology is well into its second century. This specialty within the world's fission technology community is quite unique, first because it was established as a separate effort very early in the history of world fission energy, and second because it grew in an isolated environment, with tight security requirements, in its early years. Commercial security rules later sustained a considerable degree of isolation. The pioneers of CANDU development have finished their work. Most of the second generation also has moved on. As yet, we cannot point to a consistent and complete record of this remarkable achievement. We, as a nuclear enterprise, have not captured the design legacy in a form that is readily accessible to the current and future generation of professionals involved with CANDU reactors, be they students, designers, operations staff, regulators, consultants or clients. This is a serious failure. Young people entering our field of study must make do with one or two textbooks and a huge collection of diverse technical papers augmented by limited-scope education and training materials. Those employed in the various parts of the nuclear industry rely mostly on a smaller set of CANDU- related documents available within their own organization; documents that sometimes are rather limited in scope. University professors often have even more limited access to in-depth and up to date information. In fact, they often depend on literature published in other countries when preparing lectures, enhanced by guest lecturers from various parts of the industry. Because CANDU was developed mostly inside Canada, few of these text materials contain useful data describing processes important to the CANDU system. For many years it has been recognized that

  20. Enhancement of safety analysis reliability for a CANDU-6 reactor using RELAP-CANDU/SCAN coupled code system

    International Nuclear Information System (INIS)

    Kim, Man Woong; Choi, Yong Seog; Sin, Chul; Kim, Hyun Koon; Kim, Hho Jung; Hwang, Su Hyun; Hong, In Seob; Kim, Chang Hyo

    2005-01-01

    In LOCA analysis of the CANDU reactor, the system thermal-hydraulic code, RELAP-CANDU, alone cannot predict the transient behavior accurately. Therefore, the best estimate neutronics and system thermal-hydraulic coupled code system is necessary to describe the transient behavior with higher accuracy and reliability. To perform on-line calculation of safety analysis for CANDU reactor, a coupled thermal hydraulics-neutronics code system was developed in such a way that the best-estimate thermal-hydraulic system code for CANDU reactor, RELAP-CANDU, is coupled with the full three-dimensional reactor core kinetic code

  1. Experience in the manufacture and performance of CANDU fuel for KANUPP

    International Nuclear Information System (INIS)

    Salim, M.; Ahmed, I.; Butt, P.

    1995-01-01

    Karachi Nuclear Power Plant (KANUPP) a 137 MWe CANDU unit is In operation since 1971. Initially, it was fueled with Canadian fuel bundles. In July 1980 Pakistani manufactured fuel was introduced in the reactor core, irradiated to a burnup of about 7500 MWd-teU -1 and successfully discharged in May 1984. The core was progressively fuelled with Pakistani fuel and in August 1990 the reactor core contained all Pakistani made fuel. As of the present, 3 core equivalent Pakistani fuel bundles have been successfully discharged at an average bumup of 6500 MWd-teU -1 . with a maximum burnup of ∼ 10,200 MWd-teU -1 . No fuel failure of Pakistani bundles has been observed so far. This paper presents the indigenous efforts towards manufacture and operational aspects of KANUPP fuel and compares its behaviour with that of Canadian supplied fuel. The Pakistani fuel has performed well and is as good as the Canadian fuel. (author)

  2. The future for CANDU

    International Nuclear Information System (INIS)

    Foster, J.S.

    1977-06-01

    Canada could have 60,000 MW(e) of installed nuclear-electric generating capacity by the year 2000 and have exported the plan to generate a further 5,000 MW(e). While the CANDU reactor can readily be scaled up to larger unit sizes, its real potential lies in the even greater efficiency that can be obtained by using alternative fuel cycles. The thorium - uranium-233 fuel cycle, for instance, makes it possible to attain a conversion factor of unity, or a little better, on a feed of pure thorium in a substantially unmodified CANDU reactor. Further developments, such as spallation, offer means of converting fertile to fissile material to provide a fissile inventory for an expanding system. The coincidence of expected future shortages of other energy supplies with continuing good experience in the nuclear field should assist in creating a climate that will permit accelerated nuclear power development. (author)

  3. The Thermal-hydraulic Analysis for the Aging Effect of the Component in CANDU-6 Reactor

    International Nuclear Information System (INIS)

    Bae, Jun Ho; Jung, Jong Yeob

    2014-01-01

    CANDU reactor consists of a lot of components, including pressure tube, reactor pump, steam generator, feeder pipe, and so on. These components become to have the aging characteristics as the reactor operates for a long time. The aging phenomena of these components lead to the change of operating parameters, and it finally results to the decrease of the operating safety margin. Actually, due to the aging characteristics of components, CANDU reactor power plant has the operating license for the duration of 30 years and the plant regularly check the plant operating state in the overhaul period. As the reactor experiences the aging, the reactor operators should reduce the reactor power level in order to keep the minimum safety margin, and it results to the deficit of economical profit. Therefore, in order to establish the safety margin for the aged reactor, the aging characteristics for components should be analyzed and the effect of aging of components on the operating parameter should be studied. In this study, the aging characteristics of components are analyzed and revealed how the aging of components affects to the operating parameter by using NUCIRC code. Finally, by scrutinizing the effect of operating parameter on the operating safety margin, the effect of aging of components on the safety margin has been revealed

  4. Study of seismic responses of Candu-3 reactor building using isolator bearings

    International Nuclear Information System (INIS)

    Biswas, J.K.

    1992-01-01

    Seismic isolator bearings are known to increase reliability, reduce cost and increase the potential sitings for nuclear power plants located in regions of high seismicity. High seismic activities in Canada occur mainly in the western coast, the Grand Banks and regions of Quebec along the St. Lawrence river. In Canada, nuclear power plants are located in Ontario, Quebec and New Brunswick where the seismicity levels are low to moderate. Consequently, seismic isolator bearings have not been used in the existing nuclear power plants in Canada. The present paper examines the effect of using seismic isolator bearings in the design for the new CANDU3 which would be suitable for regions having high seismicity. The CANDU3 Nuclear Power Plant is rated at 450 MW of net output power and is a smaller version of its predecessor CANDU6 successfully operating in Canada and abroad. The design of CANDU3 is being developed by AECL CANDU. Advanced technologies for design, construction and plant operation have been utilized. During the conceptual development of the CANDU3 design, various design options including the use of isolator bearings were considered. The present paper presents an overview of seismic isolation technology and summarizes the analytical work for predicting the seismic behavior of the CANDU3 reactor building. A lumped-parameter dynamic model for the reactor building is used for the analysis. The characteristics of the bearings are utilized in the analysis work. The time-history modal analysis has been used to compute the seismic responses. Seismic responses of the reactor building with and without isolator bearings are compared. The isolator bearings are found to reduce the accelerations of the reactor building. As a result, a lower level of seismic qualification for components and systems would be required. The use of these bearings however increases rigid body seismic displacements of the structure requiring special considerations in the layout and interfaces for

  5. Passive safety features for next generation CANDU power plants

    International Nuclear Information System (INIS)

    Natalizio, A.; Hart, R.S.; Lipsett, J.J.; Soedijono, P.; Dick, J.E.

    1989-01-01

    CANDU offers an evolutionary approach to simpler and safer reactors. The CANDU 3, an advanced CANDU, currently in the detailed design stage, offers significant improvements in the areas of safety, design simplicity, constructibility, operability, maintainability, schedule and cost. These are being accomplished by retaining all of the well known CANDU benefits, and by relying on the use of proven components and technologies. A major safety benefit of CANDU is the moderator system which is separate from the coolant. The presence of a cold moderator reduces the consequences arising from a LOCA or loss of heat sink event. In existing CANDU plants even the severe accident - LOCA with failure of the emergency core cooling system - is a design basis event. Further advances toward a simpler and more passively safe reactor will be made using the same evolutionary approach. Building on the strength of the moderator system to mitigate against severe accidents, a passive moderator cooling system, depending only on the law of gravity to perform its function, will be the next step of development. AECL is currently investigating a number of other features that could be incorporated in future evolutionary CANDU designs to enhance protection against accidents, and to limit off-site consequences to an acceptable level, for even the worst event. The additional features being investigated include passive decay heat removal from the heat transport system, a simpler emergency core cooling system and a containment pressure suppression/venting capability for beyond design basis events. Central to these passive decay heat removal schemes is the availability of a short-term heat sink to provide a decay heat removal capability of at least three days, without any station services. Preliminary results from these investigations confirm the feasibility of these schemes. (author)

  6. The CANDU-PHW generating system waste arisings

    International Nuclear Information System (INIS)

    Simmons, G.R.

    1979-03-01

    In this report, the volume of material and level of contained radioactive nuclides are tabulated for wastes arising from four fuel cycles which might be operated in CANDU-PHW (CANada Deuterium Uranium - Pressurized Heavy Water) reactors. The data presented, based on Canadian experience and/or studies, cover the range of conditioned waste volumes which could be expected from steady-state (no growth), CANDU-PHW-powered electrical generating systems. The wastes arising from operation and decommissioning of facilities in each phase of each fuel cycle are estimated. Each fuel cycle is considered to operate in isolation with the data given in terms of quantities per gigawatt-year of electricity produced. Three of the fuel cycles for which data are presented, the natural uranium once-through cycle, the plutonium-enriched uranium cycle (plutonium recycle) and the low-burnup uranium-enriched thorium cycle (thorium and uranium recycle), were studied by INFCE WG.7 (the International Nuclear Fuel Cycle Evaluation, Working Group 7) as fuel cycles 4, 5 and 6. The high-burnup uranium-enriched thorium cycle is included for comparison. INFCE WG.7 selected many common reference parameters which are applied uniformly to all seven INFCE WG.7 reference fuel cycles in determining waste arisings. Where these parameters differ from the data of Canadian origin given in the body of this report, the INFCE WG.7 data are given in an appendix. The waste management costs associated with operation of each INFCE WG.7 reference fuel cycle were calculated and compared by the working group. An arbitrary set of costing parameters and disposal technologies was selected by the working group for application to each of the reference fuel cycles. The waste management and disposal costs for the PHW reactor fuel cycles based on these arbitrary cost parameters are given in an appendix. (author)

  7. 1200 FPD refuelling simulation of RUFIC fuel in a CANDU 6 reactor

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Soon Young; Jeong, Chang Joon; Min, Byung Joo; Suk, Ho Chun

    2001-07-01

    The refuelling strategy of RUFIC (Recovered Uranium Fuel in CANDU) fuel as a high-burnup fuel for a CANDU 6 reactor is studied to determine the achievable operation characteristics of the fuel and reactor. In this study, three refuelling schemes of 4-, 2-, and 3-bundle shift for 0.92 w/o RUFIC fuel in an CANDU 6 reactor were individually evaluated through 1200 FPD(Full Power Day)refuelling simulaltions where the 0.92 w/o RUFIC is equivalent to CANFLEX 0.9 w/o SEU(Slightly Enriched Uranium) in reactivity and burnup respects. The computer code system used for this study is WIMS-AECL/DRAGON/RFSP. The results simulated for the case of 4-bundle shift refueling scheme shows that the peak maximum channel power and peak maximum CPPF(Channel Power Peaking Factor)of 7228 kW and 1.175, respectively, seems too high to maintain the available operating margins, because some data of the maximum channel power exceed the operating limit(7070 kW based on the Technical Specifications of Wolsong 3 and 4 Units). Whereas, the results simulated for the case of 2-bundle shift refuelling scheme shows that sufficient operating margin could be secured where the peak maximum channel power and peak maximum CPPF were 6889 kW and 1.094, respectively. However, the channel refuelling rate (channels/day) of the 2-bundle shift refuelling scheme is twice that of the 4-bundle shift refuelling scheme, and hence the 2-bundle shift refuelling would not be an economical refuelling scheme for the RUFIC fuel bundles. Therefore, a 3-bundle shift refuelling scheme for the RUFIC fuel in CANDU 6 reactor was also studied by the 1200 FPD refuelling simulation. As a result, it is found that all the operating parameters in the 3-bundle shift case are achivable for the CANDU 6 reactor operation, and the channel refuelling rate of 2.88 channels/day seems to be attractive compared to the refuelling rate of 4.32 channels/day in the 2-bundle shift case.

  8. Management of a 600 MW CANDU project to facilitate electricity export

    International Nuclear Information System (INIS)

    Gunter, G.E.

    1983-06-01

    The export of electricity from 600-MW CANDU nuclear power plants built in Canada remains feasible providing certain requirements continue to be met. The principal objective in developing nuclear power resources for export is that they must produce economically attractive electricity. A review of the experience of construction and operation of Point Lepreau Unit 1 suggests an inherent ability to reduce construction costs and shorten construction schedules so as to make electrical power output from these stations even more attractive to export customers

  9. Analyses of fluid flow and heat transfer inside calandria vessel of CANDU-6 reactor using CFD

    International Nuclear Information System (INIS)

    Yu, Seon Oh; Kim, Man Woong; Kim, Hho Jung

    2005-01-01

    In a CANDU (CANada Deuterium Uranium) reactor, fuel channel integrity depends on the coolability of the moderator as an ultimate heat sink under transient conditions such as a Loss Of Coolant Accident (LOCA) with coincident Loss Of Emergency Core Cooling (LOECC). as well as normal operating conditions. This study presents assessments of moderator thermal-hydraulic characteristics in the normal operating conditions and one transient condition for CANDU-6 reactors, using a general purpose three-dimensional computational fluid dynamics code. First, an optimized calculation scheme is obtained by many-sided comparisons of the predicted results with the related experimental data, and by evaluating the fluid flow and temperature distributions. Then, using the optimized scheme, analyses of real CANDU-6 in normal operating conditions and the transition condition have been performed. The present model successfully predicted the experimental results and also reasonably assessed the thermal-hydraulic characteristics of a real CANDU-6 with 380 fuel channels. A flow regime map with major parameters representing the flow pattern inside a calandria vessel has also proposed to be used as operational and/or regulatory guidelines

  10. Expert systems use in present and future CANDU nuclear power supply systems

    International Nuclear Information System (INIS)

    Lupton, L.R.; Basso, R.A.J.; Anderson, L.L.; Anderson, J.W.D.

    1989-11-01

    As CANDU nuclear power plants become more complex, and are operated under tighter constraints for longer periods between outages, plant operations staff will have to absorb more information to correctly and rapidly respond to upsets. A development program is underway at Atomic Energy of Canada Limited to use expert systems and interactive media tools to assist operations staff of existing and future CANDU plants. The complete system for plant information access and display, on-line advice and diagnosis, and interactive operating procedures is called the Operator Companion. A prototype, consisting of operator consoles, expert systems and simulation modules in a distributed architecture, is currently being developed to demonstrate the concepts of the Operator Companion. Specialized advisors are also being developed using expert system technology to meet specific operational and design needs

  11. Advancing CANDU technology AECL's Development program

    International Nuclear Information System (INIS)

    Torgerson, D.F.

    1997-01-01

    AECL has a comprehensive product development program that is advancing all aspects of CANDU technology including fuel and fuel cycles, fuel channels, heavy water and tritium technology, safety technology, components and systems, constructability, health and environment, and control and instrumentation. The technology arising from these programs is being incorporated into the CANDU design through an evolutionary process. This evolutionary process is focused on improving economics, enhancing safety and ensuring fuel cycle flexibility to secure fuel supply for the foreseeable future. This strategic thrusts are being used by CANDU designers and researchers to set priorities and goals for AECL's development activities. The goals are part of a 25-year development program that culminates in the 'CANDU X'. The 'CANDU X' is not a specific design - it is a concept that articulates our best extrapolation of what is achievable with the CANDU design over the next 25 years, and includes the advanced features arising from the R and D and engineering to be done over that time. AECL's current product, the 700 MWe class CANDU 6 and the 900 MWe class CANDU 9, both incorporate output from the development programs as the technology become available. A brief description of each development areas is given below. The paper ends with the conclusion that AECL has a clear vision of how CANDU technology and products will evolve over the next several years, and has structured a comprehensive development program to take full advantage of the inherent characteristics of heavy water reactors. (author)

  12. Design of a transportation cask for irradiated CANDU fuel

    International Nuclear Information System (INIS)

    Nash, K.E.; Gavin, M.E.

    1983-01-01

    A major step in the development of a large-scale transportation system for irradiated CANDU fuel is being made by Ontario Hydro in the design and construction of a demonstration cask by 1988/89. The system being designed is based on dry transportation with the eventual fully developed system providing for dry fuel loading and unloading. Research carried out to date has demonstrated that it is possible to transport irradiated CANDU fuel in a operationally efficient and simple manner without any damage which would prejudice subsequent automated fuel handling

  13. Addressing severe accidents in the CANDU 9 design

    International Nuclear Information System (INIS)

    Nijhawan, S.M.; Wight, A.L.; Snell, V.G.

    1998-01-01

    CANDU 9 is a single-unit evolutionary heavy-water reactor based on the Bruce/Darlington plants. Severe accident issues are being systematically addressed in CANDU 9, which includes a number of unique features for prevention and mitigation of severe accidents. A comprehensive severe accident program has been formulated with feedback from potential clients and the Canadian regulatory agency. Preliminary Probabilistic Safety Analyses have identified the sequences and frequency of system and human failures that may potentially lead to initial conditions indicating onset of severe core damage. Severe accident consequence analyses have used these sequences as a guide to assess passive heat sinks for the core, and containment performance. Estimates of the containment response to mass and energy injections typical of postulated severe accidents have been made and the results are presented. We find that inherent CANDU severe accident mitigation features, such as the presence of large water volumes near the fuel (moderator and shield tank), permit a relatively slow severe accident progression under most plant damage states, facilitate debris coolability and allow ample time for the operator to arrest the progression within, progressively, the fuel channels, calandria vessel or shield tank. The large-volume CANDU 9 containment design complements these features because of the long times to reach failure

  14. Report of the COG/IAEA international workshop on managing nuclear safety at CANDU (PHWR) plants. Working material

    International Nuclear Information System (INIS)

    1997-01-01

    The workshop, hosted by COG and co-sponsored by the International Atomic Energy Agency (IAEA, Vienna) was held in Toronto, April 28 - May 1st, 1997. The 40 participants included senior managers from IAEA member countries operating or constructing CANDU (PHWR) stations. All the offshore utilities with PHWR stations in Korea, Romania, India, Argentina, Pakistan, and China were present with their domestic counterparts from Ontario Hydro Nuclear, Hydro Quebec, New Brunswick Power, and AECL. The objectives of the workshop were to: provide a forum for exchange of ideas among nuclear safety managers operating CANDU (PHWR) stations and to learn from each other's experiences; to foster sharing of information on different operating approaches to managing safety and, in particular, to highlight the strategies for controlling the overall plant risk to a low level; to identify and discuss issues of mutual interest pertinent to PHWR stations and to define future follow-up activities. Refs, figs

  15. Report of the COG/IAEA international workshop on managing nuclear safety at CANDU (PHWR) plants. Working material

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1997-12-01

    The workshop, hosted by COG and co-sponsored by the International Atomic Energy Agency (IAEA, Vienna) was held in Toronto, April 28 - May 1st, 1997. The 40 participants included senior managers from IAEA member countries operating or constructing CANDU (PHWR) stations. All the offshore utilities with PHWR stations in Korea, Romania, India, Argentina, Pakistan, and China were present with their domestic counterparts from Ontario Hydro Nuclear, Hydro Quebec, New Brunswick Power, and AECL. The objectives of the workshop were to: provide a forum for exchange of ideas among nuclear safety managers operating CANDU (PHWR) stations and to learn from each other`s experiences; to foster sharing of information on different operating approaches to managing safety and, in particular, to highlight the strategies for controlling the overall plant risk to a low level; to identify and discuss issues of mutual interest pertinent to PHWR stations and to define future follow-up activities. Refs, figs.

  16. A Comparative Study on the Refueling Simulation Method for a CANDU Reactor

    Energy Technology Data Exchange (ETDEWEB)

    Do, Quang Binh; Choi, Hang Bok; Roh, Gyu Hong [Korea Atomic Energy Research Institute, Taejon (Korea, Republic of)

    2006-07-01

    The Canada deuterium uranium (CANDU) reactor calculation is typically performed by the RFSP code to obtain the power distribution upon a refueling. In order to assess the equilibrium behavior of the CANDU reactor, a few methods were suggested for a selection of the refueling channel. For example, an automatic refueling channel selection method (AUTOREFUEL) and a deterministic method (GENOVA) were developed, which were based on a reactor's operation experience and the generalized perturbation theory, respectively. Both programs were designed to keep the zone controller unit (ZCU) water level within a reasonable range during a continuous refueling simulation. However, a global optimization of the refueling simulation, that includes constraints on the discharge burn-up, maximum channel power (MCP), maximum bundle power (MBP), channel power peaking factor (CPPF) and the ZCU water level, was not achieved. In this study, an evolutionary algorithm, which is indeed a hybrid method based on the genetic algorithm, the elitism strategy and the heuristic rules for a multi-cycle and multi-objective optimization of the refueling simulation has been developed for the CANDU reactor. This paper presents the optimization model of the genetic algorithm and compares the results with those obtained by other simulation methods.

  17. Learning from experience. Feedback to design

    International Nuclear Information System (INIS)

    Hopwood, J.M.; Shalaby, B.A.; Keil, H.

    1997-01-01

    AECL has been the designer of 25 commercial scale CANDU reactors now in operation, with more under construction. AECL has taken the evolutionary approach in developing its current designs, the CANDU 6 and CANDU 9 Nuclear Power Plants. An integral part of this approach is to emphasize feedback of experience to the designers, in a continuous improvement process. AECL has implemented a formal process of gathering and responding to feedback from: NPP operation, construction and commissioning; regulatory input; R and D results: as well as paying close attention to market input. A number of recent examples of design improvement via this feedback process are described

  18. A study for good regulation of the CANDU's in Korea

    Energy Technology Data Exchange (ETDEWEB)

    Oh, Se Ki; Shin, Y. K.; Joe, S. K.; Kim, J. S.; Yu, Y. J.; Lee, Y. J. [Ajou Univ., Suwon (Korea, Republic of)

    2002-03-15

    The objective of project is to derive the policy recommendations to improve the efficiency of CANDU plants regulation. These policy recommendations will eventually contribute to the upgrading of Korean nuclear regulatory system and safety enhancement. During the second phase of this 2 years study, following research activities were done. Review the technical basis and framework of the new Canadian Regulation System and IAEA. Analysis on the interview of Wolsung operation staffs to identify important safety issues and regulation problems experienced at operation. Providing a plan of CANDU regulation system enhancement program.

  19. Mathematical modeling of CANDU-PHWR

    Energy Technology Data Exchange (ETDEWEB)

    Gaber, F.A.; Aly, R.A.; El-Shal, A.O. [Atomic Energy Authority, Cairo (Egypt)

    2003-07-01

    The paper deals with the transient studies of CANDU 600 pressurized Heavy Water Reactor (PHWR). This study involved mathematical modeling of CANDU-PHWR to study its thermodynamic performances. Modeling of CANDU-PHWR was based on lumped parameter technique. The reactor model includes the neutronic, reactivity, and fuel channel heat transfer. The nuclear reactor power was modelled using the point kinetics equations with six groups of delayed neutrons and the reactivity feed back due to the changes in the fuel temperature and coolant temperature. The CANDU-PHWR model was coded in FORTRAN language and solved by using a standard numerical technique. The adequacy of the model was tested by assessing the physical plausibility of the obtained results. (author)

  20. Fuel Management Study for a CANDU reactor Using New Physics Codes Suite

    International Nuclear Information System (INIS)

    Kim, Won Young; Kim, Bong Ghi; Park, Joo Hwan

    2008-01-01

    A CANDU reactor is a heavy-water-moderated, natural uranium fuelled reactor with a pressure tube. The reactor contains a horizontal cylindrical vessel (calandria) and each pressure tube is isolated from the heavy-water moderator in a calandria. This allows the moderator system to be operated of a high-pressure and of a high-temperature coolant in pressure tube. The primary reactivity control in a CANDU reactor is the on-power refueling on a daily basis and an additional reactivity control is provided through an individual reactivity device movement, which includes 21 adjusters, 6 liquid zone controllers, 4 mechanical control absorbers and 2 shutdown systems. The refueling in CANDU is carried out on power and this makes the in-core fuel management different from that in a reactor refueled during shutdowns. The objective of a fuel management is to determine a fuel loading and fuel replacement procedure which will result in a minimum total unit energy cost in a safe and reliable operation. In this article, the in-core fuel management for the CANDU reactor was studied by using the new physics code suite of WIMS-IST/DRAGON-IST/RFSP-IST with the model of Wolsong-1 NPP

  1. Data base for a CANDU-PHW operating on the thorium cycle

    International Nuclear Information System (INIS)

    1979-07-01

    This report, prepared for INFCE, gives data for an extrapolated 1000 MW(e) CANDU-PHW design operating on various thorium cycles. In all these cycles thorium is the main fertile component of the fuel and all assume recycling of the uranium component. In the reference cycle, the requirements for externally supplied fissile material are met using U-235, with the feed adjusted to provide a fuel burnup of approximately 30,000 MW.d/t(U). Two versions of the reference cycle are treated. In one, the U-235 is supplied in a highly enriched form (93% U-235 in uranium); in the other, the U-235 is supplied at a lower enrichment, such that the uranium present in the feed fuel is ''denatured''. The effects of varying the fuel burnup and the recycle delay time are discussed for the reference cases. Data are also given for thorium cycles using plutonium instead of U-235 to meet requirements for externally supplied fissile material. The special case of ''self sufficient equilibrium thorium cycles'', which require no external source of fissile material for equilibrium operation, is also treated

  2. CANDU 6 - the highly successful medium sized reactor

    International Nuclear Information System (INIS)

    Hedges, K. R.; Allen, P. J.; Hopwood, J. M.

    2000-01-01

    The CANDU 6 Pressurized Heavy Water Reactor system, featuring horizontal fuel channels and heavy water moderator continues to evolve, supported by AECL's strong commitment to comprehensive R and D programs. The initial CANDU 6 design started in the 1970's. The first plants went into service in 1983, and the latest version of the plant is under construction in China. With each plant the technology has evolved giving the dual advantages of proveness and modern technology. CANDU 6 delivers important advantages of the CANDU system with benefit to small and medium-sized grids. This technology has been successfully adopted by, and localized to varying extents in, each of the CANDU 6 markets. For example, all CANDU owners obtain their fuel from domestic suppliers. Progressive CANDU development continues at AECL to enhance this medium size product CANDU 6. There are three key CANDU development strategic thrusts: improved economics, fuel cycle flexibility, and enhanced safety. The CANDU 6 product is also enhanced by incorporating improvements and advanced features that will be arising from our CANDU Technology R and D programs in areas such as heavy water and tritium, control and instrumentation, fuel and fuel cycles, systems and equipment and safety and constructability. (author)

  3. The final report of ''on-the-job training'' on the CANDU reactor

    International Nuclear Information System (INIS)

    Kim, D.H.; Koh, B.J.

    1983-01-01

    This is the final Report for the technical ''on-the-job traning'' for the Wolsung CANDU nuclear power plant which is the first Pressurized Heavy Water Reactor setting up in Korea. The technical ''on-the-job traning'' was established to increase the capability for the nuclear safety evaluation in order to contribute the future safe operation of the CANDU nuclear power plant. The training has been excuted through three level courses as elementary, intermediate and ''on-the-job training'' at Wolsung power plant. The elementary course was introduction to the CANDU basics and fundamentals. The intermediate course was the more advanced course, and the detailed concepts and engineering explanations of the CANDU system had been instructed. The third course was the ''on-the-job training'' at the Wolsung plant site, which was the most emphasized course during the project. (Author)

  4. AECL's support to operating plants world wide

    International Nuclear Information System (INIS)

    Azeez, S.; Kakaria, B.K.; Hinchley, E.M.

    1998-01-01

    Through their operating records, CANDU reactors have established themselves as a successful and cost-effective source of electricity in Canada and abroad. They have proven to be safe, reliable and economical. A variety of factors have contributed to the enviable CANDU record, such as a sound design based on proven principles supported by effective development programs, along with dedicated plant owners committed to excellence in safely maintaining and operating their plants. Atomic Energy of Canada Limited (AECL), the CANDU designer, has continuously maintained a close relationship with owners/operators of the plants in Canada, Argentina, Romania and South Korea. AECL and the plant operators have all benefited from this strengthening relationship by sharing experience and information. CANDU plant operators have been required to respond decisively to the economic realities of downward cost pressures and deregulation. Operating, Maintenance and Administration (OM and A) costs are being given a new focus as plant owners review each cost element to improve the economic returns from their investments. Amongst the three main OM and A constituents, plant maintenance costs are the most variable and have the largest influence on effective plant operations. The correlation between effective plant maintenance and high capacity factors shows clearly the importance of proactive maintenance planning to reduce the frequency and duration of forced plant outages and their negative impacts on plant economics. This paper describes the management processes and organizational structures m AECL that support plant operations and maintenance in operating CANDU plants with cost effective products and services. (author)

  5. Preliminary analysis for u tube degradation in CANDU steam generator using CATHENA

    Energy Technology Data Exchange (ETDEWEB)

    Shin, So Eun; Lee, Jeong Hun; Park, Tong Kyu; Hwang, Su Hyun [FNC Technology Co., Seoul (Korea, Republic of); Jung, Jong Yeo [KAERI, Daejeon (Korea, Republic of)

    2012-10-15

    The interest in plant safety and integrity has been increasing due to long term operation of nuclear power plants (NPPs) and lots of efforts have been devoted to developing the degradation evaluation model for all the Structure, System, and Components (SSCs) of NPPs in these days. The efforts, however, were mainly concentrated on pressurized light water reactors (PWRs) in domestic. In contrast, the study for the aging degradation of counterparts of CANDU (CANada Deuterium Uranium) reactors has been rarely performed, even though Wolsong unit 1 (WS1), that is a CANDU 6 NPP in Korea, has been operating for almost 30 years. Therefore, the assessment of the aging degradation is required and the proper and exact evaluation model for the aging degradation of SCCs of CANDU, especially WS1, is urgently needed. In this study, the aging degradation of steam generators (SGs) in WS1 was mainly discussed. Based on cases of the aging degradation of SGs in overseas CANDU reactors, the major potential aging mechanisms of SGs were estimated since there has been no case of accident due to degradation in CANDU NPPs in Korea . Some core parameters which are indicators of the degree of degradation were calculated by CATHENA (Canadian algorithm for thermal hydraulic network analysis). In the result of comparing two calculation cases; core parameters for only aged SGs in fresh plant and those for all the aged component, it can be concluded that aging of SGs is a main component in the degradation assessment of CANDU NPPs, and keeping the integrity of steam generator (SG) tubes is important to guarantee the safety of the NPPs.

  6. Impact of aging and material structure on CANDU plant performance

    Energy Technology Data Exchange (ETDEWEB)

    Nadeau, E.; Ballyk, J.; Ghalavand, N. [Candu Energy Inc., Mississauga, Ontario (Canada)

    2011-07-01

    In-service behaviour of pressure tubes is a key factor in the assessment of safety margins during plant operation. Pressure tube deformation (diametral expansion) affects fuel bundle dry out characteristics resulting in reduced margin to trip for some events. Pressure tube aging mechanisms also erode design margins on fuel channels or interfacing reactor components. The degradation mechanisms of interest are primarily deformation, loss of fracture resistance and hydrogen ingress. CANDU (CANada Deuterium Uranium, a registered trademark of the Atomic Energy of Canada Limited used under exclusive licence by Candu Energy Inc.) owners and operators need to maximize plant capacity factor and meet or exceed the reactor design life targets while maintaining safety margins. The degradation of pressure tube material and geometry are characterized through a program of inspection, material surveillance and assessment and need to be managed to optimize plant performance. Candu is improving pressure tubes installed in new build and life extension projects. Improvements include changes designed to reduce or mitigate the impact of pressure tube elongation and diametral expansion rates, improvement of pressure tube fracture properties, and reduction of the implications of hydrogen ingress. In addition, Candu provides an extensive array of engineering services designed to assess the condition of pressure tubes and address the impact of pressure tube degradation on safety margins and plant performance. These services include periodic and in-service inspection and material surveillance of pressure tubes and deterministic and probabilistic assessment of pressure tube fitness for service to applicable standards. Activities designed to mitigate the impact of pressure tube deformation on safety margins include steam generator cleaning, which improves trip margins, and trip design assessment to optimize reactor trip set points restoring safety and operating margins. This paper provides an

  7. Feasibility study of CANDU-9 fuel handling system

    Energy Technology Data Exchange (ETDEWEB)

    Hwang, Jeong Ki; Jo, C. H.; Kim, H. M.

    1996-12-01

    CANDU`s combination of natural uranium, heavy water and on-power refuelling is unique in its design and remarkable for reliable power production. In order to offer more output, better site utilization, shorter construction time, improved station layout, safety enhancements and better control panel layout, CANDU-9 is now under development with design improvement added to all proven CANDU advantages or applicable technologies. One of its major improvement has been applied to fuel handling system. This system is very similar to that of CANDU-3, and some parts of the system are applied to those of the existing CANDU-6 or CANDU-9. Design concepts and design requirements of fuel handling system for CANDU-9 have been identified to compare with those of the existing CANDU and the design feasibilities have been evaluated. (author). 4 tabs., 13 figs., 9 refs.

  8. A survey on the corrosion susceptibility of Alloy 800 CANDU steam generator tubing materials

    International Nuclear Information System (INIS)

    Lu, Y.C.; Dupuis, M.; Burns, D.

    2008-01-01

    To provide support for a proactive steam generator (SG) aging management strategy, a survey on the corrosion susceptibility of the archived Alloy 800 tubing from CANDU SGs under plausible crevice chemistry conditions was conducted to assess the potential material degradation issues in CANDU SGs. Archived Alloy 800 samples were collected from four CANDU utilities. High-temperature electrochemical analysis was carried out to assess the corrosion susceptibility of the archived SG tubing under simulated CANDU crevice chemistry conditions at both 150 o C and 300 o C. The potentiodynamic polarization results obtained from the archived CANDU SG tubes were compared to the data from ex-service tubes removed from Darlington Nuclear Generating Station (DNGS) SGs and a reference nuclear grade Alloy 800 tubing. It was found that the removed Darlington SG tubes, with signs of in-service degradation, were more susceptible to pitting corrosion than the reference nuclear grade Alloy 800 tubing. At 150 o C, under the same neutral crevice chemistry conditions, the potentiodynamic polarization curve of the ex-service Darlington SG tubing has an active peak, which is a sign of propensity to crevice/underdeposit corrosion. This active peak was not observed in any of the potentiodynamic polarization curves of all archived Alloy 800 CANDU SG tubing indicating that archived CANDU SG tubes are less susceptible to the underdeposit corrosion under SG startup conditions. The corrosion behaviour of the archived Alloy 800 tubes from CANDU SG was similar to that of the reference nuclear grade Alloy 800 tubing. The results of this survey suggest that the Alloy 800 tubing materials used in the existing CANDU utilities (other than ex-service DNGS tubing) will continue to have reliable performance under specified CANDU operating conditions. Ex-service SG tubing from DNGS, although showing lower than average corrosion resistance, still has a wide acceptable operating margin and the in

  9. Establishment of Safety Analysis System and Technology for CANDU Reactors

    International Nuclear Information System (INIS)

    Min, Byung Joo; Kim, W. Y.; Kim, H. T.; Rhee, B. W.; Yoon, C.; Kang, H. S.; Yoo, K. J.

    2005-03-01

    To improve the CANDU design/operation safety analysis codes and the CANDU safety analysis methodology, the following works have been done. From the development of the lattice codes (WIMS/CANDU), the lattice model simulates the real core lattice geometry and the effect of the pressure tube creep to the core lattice parameter has been evaluated. From the development of the 3-dimensional thermal-hydraulic analysis model of the moderator behavior (CFX4-CAMO), validation of the model against STERN Lab experiment has been executed. The butterfly-shaped grid structure and the 3-dimensional flow resistance model for porous media were developed and applied to the moderator analysis for Wolsong units 2/3/4. The single fuel channel analysis codes for blowdown and post-blowdown were unified by CATHENA. The 3-dimensional fuel channel analysis model (CFX-CACH) has been developed for validation of CATHENA fuel channel analysis model. The interlinking analysis system (CANVAS) of the thermal-hydraulic safety analysis codes for the primary heat transport system and containment system has been executed. The database system of core physics and thermal-hydraulics experimental data for safety analysis has been established on the URL: http://CANTHIS.kaeri.re.kr. For documentation and Standardization of the general safety analysis procedure, the general safety analysis procedure is developed and applied to a large break LOCA. The present research results can be utilized for establishment of the independent safety analysis technology and acquisition of the optimal safety analysis technology

  10. CANDU design options with detritiation

    International Nuclear Information System (INIS)

    Wren, D.J.; Hart, R.S.

    1997-01-01

    CANDU reactors include a number of auxiliary systems to manage the inventory, purification, clean-up and isotopic purity of the heavy water used in the moderator and heat transport system. These systems are designed and installed to treat the moderator and heat transport water in separate parallel systems. One of the reasons for this parallel approach to heavy water management is the tritium inventory in the heavy water. Different levels of tritium accumulate in the moderator and heat transport system during reactor operation, with the moderator water having a much higher tritium concentration. Strict separation of the high- tritium-concentration moderator water from the low-tritium-concentration heat transport system water is an integral component of the CANDU design and operating strategy to limit potential releases of tritium to the containment building atmosphere. AECL is developing a new cost-effective technology for the detritiation of heavy water based on the Combined Electrolysis and Catalytic Exchange (CECE) process. This detritiation technology has the potential to be integrated into the heavy water management systems of a CANDU reactor. On-line detritiation could be used to limit the concentration of tritium in the moderator and also to detritiate any water collected within the containment building from other sources. The availability of economic detritiation technology would provide a flexibility to redesign some of the auxiliary heavy water management systems. In particular, there is potential to eliminate some of the duplication in the current management systems and also reduce costs by reclassifying some reactor systems that would have lower maximum tritium concentrations. This paper discusses some of the advantages of detritiation and some of the conceptual design options that detritiation would provide. The goal would be to lower the overall reactor cost with detritiation, but it is premature to assess whether this goal can be achieved. (author)

  11. Thorium-Based Fuels Preliminary Lattice Cell Studies for Candu Reactors

    International Nuclear Information System (INIS)

    Margeanu, C.A.; Rizoiu, A.C.

    2009-01-01

    The choice of nuclear power as a major contributor to the future global energy needs must take into account acceptable risks of nuclear weapon proliferation, in addition to economic competitiveness, acceptable safety standards, and acceptable waste disposal options. Candu reactors offer a proven technology, safe and reliable reactor technology, with an interesting evolutionary potential for proliferation resistance, their versatility for various fuel cycles creating premises for a better utilization of global fuel resources. Candu reactors impressive degree of fuel cycle flexibility is a consequence of its channel design, excellent neutron economy, on-power refueling, and simple fuel bundle. These features facilitate the introduction and exploitation of various fuel cycles in Candu reactors in an evolutionary fashion. The main reasons for our interest in Thorium-based fuel cycles have been, globally, to extend the energy obtainable from natural Uranium and, locally, to provide a greater degree of energy self-reliance. Applying the once through Thorium (OTT) cycle in existing and advanced Candu reactors might be seen as an evaluative concept for the sustainable development both from the economic and waste management points of view. Two Candu fuel bundles project will be used for the proposed analysis, namely the Candu standard fuel bundle with 37 fuel elements and the CANFLEX fuel bundle with 43 fuel elements. Using the Canadian proposed scheme - loading mixed ThO 2 -SEU CANFLEX bundles in Candu 6 reactors - simulated at lattice cell level led to promising conclusions on operation at higher fuel burnups, reduction of the fissile content to the end of the cycle, minor actinide content reduction in the spent fuel, reduction of the spent fuel radiotoxicity, presence of radionuclides emitting strong gamma radiation for proliferation resistance benefit. The calculations were performed using the lattice codes WIMS and Dragon (together with the corresponding nuclear data

  12. Evaluation of gap heat transfer model in ELESTRES for CANDU fuel element under normal operating conditions

    International Nuclear Information System (INIS)

    Lee, Kang Moon; Ohn, Myung Ryong; Im, Hong Sik; Choi, Jong Hoh; Hwang, Soon Taek

    1995-01-01

    The gap conductance between the fuel and the sheath depends strongly on the gap width and has a significant influence on the amount of initial stored energy. The modified Ross and Stoute gap conductance model in ELESTRES is based on a simplified thermal deformation model for steady-state fuel temperature calculations. A review on a series of experiments reveals that fuel pellets crack, relocate, and are eccentrically positioned within the sheath rather than solid concentric cylinders. In this paper, the two recently-proposed gap conductance models (offset gap model and relocated gap model) are described and are applied to calculate the fuel-sheath gap conductances under experimental conditions and normal operating conditions in CANDU reactors. The good agreement between the experimentally-inferred and calculated gap conductance values demonstrates that the modified Ross and Stoute model was implemented correctly in ELESTRES. The predictions of the modified Ross and Stoute model provide conservative values for gap heat transfer and fuel surface temperature compared to the offset gap and relocated gap models for a limiting power envelope. 13 figs., 3 tabs., 16 refs. (Author)

  13. Lessons learned from current Qinshan CANDU project and the impact on future NPP's

    International Nuclear Information System (INIS)

    Hedges, K. R.; Didsbury, R.; Yu, S. K. W.

    2000-01-01

    AECL has adopted an evolutionary approach to the development of the CANDU 6 and CANDU 9 Nuclear Power Plant (NPP) designs. Each new NPP project benefits from previous projects and contains an increasing number of fully proven enhancements. In accordance with this evolutionary design approach, AECL has built on the Wolsong and Qinshan successes and the solid performance of the reference CANDU stations to define, review and implement the enhancements for the CANDU 9 NPP. Some of these enhancements include fully integrated project information systems and databases, safety enhancements coming from PSA studies and licensing activities, distributed control systems for plant-wide control and an advanced control center which addresses human factors engineering concepts. Examples of the Qinshan CANDU project delivery enhancements are the utilization of electronic engineering tools for the complete plant, and the linking of these tools with the project material management system and document management systems. The project information is reviewed and approved at the engineering office in Canada and then transmitted to site electronically. Once the electronic data is at site the information packages are extracted as necessary to enable construction and facilitate contract needs with minimum effort. This paper will provide details of the CANDU Qinshan project experiences as well as describing some of the corresponding CANDU 9 enhancements. (author)

  14. Passive heat removal in CANDU

    International Nuclear Information System (INIS)

    Hart, R.S.

    1997-01-01

    CANDU has a tradition of incorporating passive systems and passive components whenever they are shown to offer performance that is equal to or better than that of active systems, and to be economic. Examples include the two independent shutdown systems that employ gravity and stored energy respectively, the dousing subsystem of the CANDU 6 containment system, and the ability of the moderator to cool the fuel in the event that all coolant is lost from the fuel channels. CANDU 9 continues this tradition, incorporating a reserve water system (RWS) that increases the inventory of water in the reactor building and profiles a passive source of makeup water and/or heat sinks to various key process systems. The key component of the CANDU 9 reserve water system is a large (2500 cubic metres) water tank located at a high elevation in the reactor building. The reserve water system, while incorporating the recovery system functions, and the non-dousing functions of the dousing tank in CANDU 6, embraces other key systems to significantly extend the passive makeup/heat sink capability. The capabilities of the reserve water system include makeup to the steam generators secondary side if all other sources of water are lost; makeup to the heat transport system in the event of a leak in excess of the D 2 O makeup system capability; makeup to the moderator in the event of a moderator leak when the moderator heat sink is required; makeup to the emergency core cooling (ECC) system to assure NPSH to the ECC pumps during a loss of coolant accident (LOCA), and provision of a passive heat sink for the shield cooling system. Other passive designs are now being developed by AECL. These will be incorporated in future CANDU plants when their performance has been fully proven. This paper reviews the passive heat removal systems and features of current CANDU plants and the CANDU 9, and briefly reviews some of the passive heat removal concepts now being developed. (author)

  15. CANDU severe accident analysis

    International Nuclear Information System (INIS)

    Negut, Gheorghe; Catana, Alexandru; Prisecaru, Ilie; Dupleac, Daniel

    2007-01-01

    Romania is a EU member since January first 2007. This country faces now new challenges which imply also the nuclear power reactors now in operation. Romania operates since 1996 a CANDU nuclear power reactor and soon will start up a second unit. In EU PWR reactors are mostly operated, so that the Romania's reactors have to meet EU standards. Safety analysis guidelines require to model severe accidents for reactors of this type. Starting from previous studies a thermal-hydraulic model for a degraded CANDU core was developed. The initiating event is assumed to be a LOCA with simultaneous loss of moderator and coolant and the failure of emergency core cooling system (ECCS). This type of accident is likely to modify the reactor geometry and will lead to a severe accident development. When the coolant temperatures inside a pressure tube reaches 1000 deg. C, a contact between pressure tube and calandria tube occurs and the decay heat is transferred to the moderator. Due to the lack of cooling, the moderator eventually begins to boil and is expelled, through the calandria vessel relief ducts, into the containment. Therefore the calandria tubes (fuel channels) uncover, then disintegrate and fall down to the calandria vessel bottom. All the quantity of calandria moderator is vaporized and expelled, the debris will heat up and eventually boil. The heat accumulated in the molten debris will be transferred through the calandria vessel wall to the shield water tank surrounding the calandria vessel. The thermal hydraulics phenomena described above are modeled, analyzed and compared with the existing data. (authors)

  16. Thermal hydraulic simulation of the CANDU nuclear reactor

    Energy Technology Data Exchange (ETDEWEB)

    Carvalho, Athos M.S.S. de; Ramos, Mario C.; Costa, Antonella L.; Fernandes, Gustavo H.N., E-mail: athos1495@yahoo.com.br [Universidade Federal de Minas Gerais (UFMG), Belo Horizonte, MG (Brazil). Departamento de Engenharia Nuclear; Instituto Nacional de Ciência e Tecnologia de Reatores Nucleares Inovadores (INCT/CNPq), Rio de janeiro, RJ (Brazil)

    2017-07-01

    The CANDU (Canada Deuterium Uranium) is a Canadian-designed power reactor of PHWR type (Pressurized Heavy Water Reactor) that uses heavy water (deuterium oxide) for moderator and coolant, and natural uranium for fuel. There are about 47 reactors of this type in operation around the world generating more than 23 GWe, highlighting the importance of this kind of device. In this way, the main purpose of this study is to develop a thermal hydraulic model for a CANDU reactor to aggregate knowledge in this line of research. In this way, a core modeling was performed using RELAP5-3D code. Results were compared with reference data to verify the model behavior in steady state operation. Thermal hydraulic parameters as temperature, pressure and mass flow rate were verified and the results are in good agreement with reference data, as it is being presented in this work. (author)

  17. Some notes on the Timing of Geological Disposal of CANDU Spent Fuels

    International Nuclear Information System (INIS)

    Choi, Heui Joo; Kook, Dong Hak; Choi, Jong Won

    2010-01-01

    CANDU spent fuel is to be disposed of at repository finally rather than recycled because of its low fissile nuclide concentration. But the difficult situation of finding a repository site can not help introducing a interim storage in the short term. It is required to find an optimum timing of geological disposal of CANDU spent fuels related to the interim storage operation period. The major factors for determining the disposal starting time are considered as safety, economics, and public acceptance. Safety factor is compared in terms of the decay heat and non-proliferation. Economics factor is compared from the point of the operation cost, and public acceptance factor is reviewed from the point of retrievability and inter-generation ethics. This paper recommended the best solution for the disposal starting time by analyzing the above factors. It is concluded that the optimum timing for the CANDU spent fuel disposal is around 2041 and that the sooner disposal time, the better from the point of technical and safety aspects.

  18. Comparative evaluation of fuel temperature coefficient of standard and CANFLEX fuels in CANDU 6

    International Nuclear Information System (INIS)

    Kim, Woosong; Hartant, Donny; Kim, Yonghee

    2012-01-01

    The fuel temperature reactivity coefficient (FTC) of CANDU 6 has become a concerning issue. The FTC was found to be slightly positive for the operating condition of CANDU 6. Since CANDU 6 has unique fuel arrangement and very soft neutron spectrum, its Doppler reactivity feedback of U 238 is rather weak. The upscattering by oxygen in fuel and Pu 239 buildup with fuel depletion are responsible for the positive FTC value at high temperature. In this study, FTC of both standard CANDU and CANFLEX fuel lattice are re evaluated. A Monte Carlo code Serpent2 was chosen as the analysis tool because of its high calculational speed and it can account for the thermal motion of heavy nuclides in fuel by using the Doppler Broadening Rejection Correction (DBRC) method. It was reported that the fuel Doppler effect is noticeably enhanced by accounting the target thermal motion. Recently, it was found that the FTC of the CANDU 6 standard fuel is noticeably enhanced by the DBRC

  19. Some aspects of primary and secondary water chemistry in CANDU reactors

    International Nuclear Information System (INIS)

    LeSurf, J.E.

    1978-09-01

    A brief review of the water chemistry in various circuits of CANDU reactors is given. Then, five particular aspects of recent work are highlighted: (i) Radiation Field Growth: in-reactor and out-reactor studies have related water chemistry to corrosion product deposition on fuel sheaths and subsequent contamination of out-core surfaces. (ii) Metal Oxide Solubility: novel techniques are being used to measure the solubilities of metal oxides at primary circuit conditions. (iii) Decontamination: the use of heavy water as coolant in CANDU reactors led to the development of a unique decontamination strategy and technique, called CAN-DECON, which has attracted the attention of operators of light-water reactors. (iv) Steam Generator Corrosion: mathematical modelling of the water chemistry in the bulk and crevice regions of nuclear steam generators, supported by chemical experiments, has shown why sea water ingress from leaking condensers can be damaging, and has provided a rapid way to evaluate alternative boiler water chemistries. (v) Automatic Control of Feedwater Chemistry: on-line automatic chemical analysis and computer control of feedwater chemistry provides All Volatile Treatment for normal operation with pure feedwater, and carefully controlled sodium phosphate addition when there is detectable sea-water ingress from leaking condensers. (author)

  20. Evaluation of CANDU6 PCR (power coefficient of reactivity) with a 3-D whole-core Monte Carlo Analysis

    International Nuclear Information System (INIS)

    Motalab, Mohammad Abdul; Kim, Woosong; Kim, Yonghee

    2015-01-01

    Highlights: • The PCR of the CANDU6 reactor is slightly negative at low power, e.g. <80% P. • Doppler broadening of scattering resonances improves noticeably the FTC and make the PCR more negative or less positive in CANDU6. • The elevated inlet coolant condition can worsen significantly the PCR of CANDU6. • Improved design tools are needed for the safety evaluation of CANDU6 reactor. - Abstract: The power coefficient of reactivity (PCR) is a very important parameter for inherent safety and stability of nuclear reactors. The combined effect of a relatively less negative fuel temperature coefficient and a positive coolant temperature coefficient make the CANDU6 (CANada Deuterium Uranium) PCR very close to zero. In the original CANDU6 design, the PCR was calculated to be clearly negative. However, the latest physics design tools predict that the PCR is slightly positive for a wide operational range of reactor power. It is upon this contradictory observation that the CANDU6 PCR is re-evaluated in this work. In our previous study, the CANDU6 PCR was evaluated through a standard lattice analysis at mid-burnup and was found to be negative at low power. In this paper, the study was extended to a detailed 3-D CANDU6 whole-core model using the Monte Carlo code Serpent2. The Doppler broadening rejection correction (DBRC) method was implemented in the Serpent2 code in order to take into account thermal motion of the heavy uranium nucleus in the neutron-U scattering reactions. Time-average equilibrium core was considered for the evaluation of the representative PCR of CANDU6. Two thermal hydraulic models were considered in this work: one at design condition and the other at operating condition. Bundle-wise distributions of the coolant properties are modeled and the bundle-wise fuel temperature is also considered in this study. The evaluated nuclear data library ENDF/B-VII.0 was used throughout this Serpent2 evaluation. In these Monte Carlo calculations, a large number

  1. CANDU safety under severe accidents

    International Nuclear Information System (INIS)

    Snell, V.G.; Howieson, J.Q.; Alikhan, S.; Frescura, G.M.; King, F.; Rogers, J.T.; Tamm, H.

    1996-01-01

    The characteristics of the CANDU reactor relevant to severe accidents are set first by the inherent properties of the design, and second by the Canadian safety/licensing approach. The pressure-tube concept allows the separate, low-pressure, heavy-water moderator to act as a backup heat sink even if there is no water in the fuel channels. Should this also fail, the calandria shell itself can contain the debris, with heat being transferred to the water-filled shield tank around the core. Should the severe core damage sequence progress further, the shield tank and the concrete reactor vault significantly delay the challenge to containment. Furthermore, should core melt lead to containment overpressure, the containment behaviour is such that leaks through the concrete containment wall reduce the possibility of catastrophic structural failure. The Canadian licensing philosophy requires that each accident, together with failure of each safety system in turn, be assessed (and specified dose limits met) as part of the design and licensing basis. In response, designers have provided CANDUs with two independent dedicated shutdown systems, and the likelihood of Anticipated Transients Without Scram is negligible. Probabilistic safety assessment studies have been performed on operating CANDU plants, and on the 4 x 880 MW(e) Darlington station now under construction; furthermore a scoping risk assessment has been done for a CANDU 600 plant. They indicate that the summed severe core damage frequency is of the order of 5 x 10 -6 /year. 95 refs, 3 tabs

  2. CANDU safety under severe accidents

    Energy Technology Data Exchange (ETDEWEB)

    Snell, V G; Howieson, J Q [Atomic Energy of Canada Ltd. (Canada); Alikhan, S [New Brunswick Electric Power Commission (Canada); Frescura, G M; King, F [Ontario Hydro (Canada); Rogers, J T [Carleton Univ., Ottawa, ON (Canada); Tamm, H [Atomic Energy of Canada Ltd. (Canada). Whiteshell Research Lab.

    1996-12-01

    The characteristics of the CANDU reactor relevant to severe accidents are set first by the inherent properties of the design, and second by the Canadian safety/licensing approach. The pressure-tube concept allows the separate, low-pressure, heavy-water moderator to act as a backup heat sink even if there is no water in the fuel channels. Should this also fail, the calandria shell itself can contain the debris, with heat being transferred to the water-filled shield tank around the core. Should the severe core damage sequence progress further, the shield tank and the concrete reactor vault significantly delay the challenge to containment. Furthermore, should core melt lead to containment overpressure, the containment behaviour is such that leaks through the concrete containment wall reduce the possibility of catastrophic structural failure. The Canadian licensing philosophy requires that each accident, together with failure of each safety system in turn, be assessed (and specified dose limits met) as part of the design and licensing basis. In response, designers have provided CANDUs with two independent dedicated shutdown systems, and the likelihood of Anticipated Transients Without Scram is negligible. Probabilistic safety assessment studies have been performed on operating CANDU plants, and on the 4 x 880 MW(e) Darlington station now under construction; furthermore a scoping risk assessment has been done for a CANDU 600 plant. They indicate that the summed severe core damage frequency is of the order of 5 x 10{sup -6}/year. 95 refs, 3 tabs.

  3. CANDU flexible and economical fuel technology in China

    Energy Technology Data Exchange (ETDEWEB)

    Mingjun, C. [CNNC Nuclear Power Operation Management Co., Zhejiang (China); Zhenhua, Z.; Zhiliang, M. [CNNC Third Qinshan Nuclear Power Co., Zhejiang (China); Cottrell, C.M.; Kuran, S. [Candu Energy Inc., Mississauga, ON (Canada)

    2014-07-01

    Use in CANDU reactor is one good option of recycled uranium (RU) and thorium (Th) resource. It is also good economy to CANDU fuel. Since 2008 Qinshan CANDU Plant and our partners (Candu Energy and CNNC and NPIC) have made great efforts to develop the engineering technologies of Flexible and Economical Fuel (RU and Th) in CANDU type reactor and finding the CANDU's position in Chinese closed fuel cycle (CFC) system. This paper presents a proposal of developing strategy and implementation plan. Qinshan CANDU reactors will be converted to use recycled and depleted uranium based fuels, a first-of-its-kind. The fuel is composed of both recycled and depleted uranium and simulating natural uranium behavior. This paper discusses its development, design, manufacture and verification tested with success and the full core implementation plan by the end of 2014. (author)

  4. Marketing CANDU internationally

    International Nuclear Information System (INIS)

    Langstaff, J.H.

    1980-06-01

    The market for CANDU reactor sales, both international and domestic, is reviewed. It is reasonable to expect that between five and ten reactors can be sold outside Canada before the end of the centry, and new domestic orders should be forthcoming as well. AECL International has been created to market CANDU, and is working together with the Canadian nuclear industry to promote the reactor and to assemble an attractive package that can be offered abroad. (L.L.)

  5. Development of best estimate auditing code for CANDU thermal hydraulic safety analysis

    International Nuclear Information System (INIS)

    Hwnag, M.

    2001-04-01

    The main purpose of this study is to develop a thermal hydraulic auditing code for the CANDU reactor, modifying the model of existing PWR auditing tool , i.e. RELAP5/MOD3. This scope of project is a fourth step of the whole project, applying the RELAP5/MOD3/CANDU+ version for the real CANDU plant LOCA Analysis and D2O leakage incident. There are three main models under investigation, i.e. Moody critical flow model, flow regime model of horizontal CANDU bundle, and fuel element heatup model when the stratification occurs, especially when CANDU LOCA is tested. Also, for Wolsung unit 1 D2O leakage incident analysis, the plant behavior is predicited with the newly developed version for the first 1000 seconds after onset of the incident, with the main interest aiming for system pressure, level control system, and thermal hydraulic transient behavior of the secondary system. The model applided for this particular application includes heat transfer model of nuclear fuel assembly, decay heat model, and MOV (Motor Operated Valve) model. Finally, the code maintenance work, mainly correcting the known errors, is presented

  6. Core analysis during transition from 37-element fuel to CANFLEX-NU fuel in CANDU 6

    Energy Technology Data Exchange (ETDEWEB)

    Jeong, Chang Joon; Suk, Ho Chun [Korea Atomic Energy Research Institute, Taejon (Korea, Republic of)

    1999-12-31

    An 1200-day time-dependent fuel-management for the transition from 37-element fuel to CANFLEX-NU fuel in a CANDU 6 reactor has been simulated to show the compatibility of the CANFLEX-NU fuel with the reactor operation. The simulation calculations were carried out with the RFSP code, provided by cell averaged fuel properties obtained from the POWDERPUFS-V code. The refueling scheme for both fuels was an eight bundle shift at a time. The simulation results show that the maximum channel and bundle powers were maintained below the license limit of the CANDU 6. This indicates that the CANFLEX-NU fuel bundle is compatible with the CANDU 6 reactor operation during the transition period. 3 refs., 2 figs., 1 tab. (Author)

  7. Core analysis during transition from 37-element fuel to CANFLEX-NU fuel in CANDU 6

    Energy Technology Data Exchange (ETDEWEB)

    Jeong, Chang Joon; Suk, Ho Chun [Korea Atomic Energy Research Institute, Taejon (Korea, Republic of)

    1998-12-31

    An 1200-day time-dependent fuel-management for the transition from 37-element fuel to CANFLEX-NU fuel in a CANDU 6 reactor has been simulated to show the compatibility of the CANFLEX-NU fuel with the reactor operation. The simulation calculations were carried out with the RFSP code, provided by cell averaged fuel properties obtained from the POWDERPUFS-V code. The refueling scheme for both fuels was an eight bundle shift at a time. The simulation results show that the maximum channel and bundle powers were maintained below the license limit of the CANDU 6. This indicates that the CANFLEX-NU fuel bundle is compatible with the CANDU 6 reactor operation during the transition period. 3 refs., 2 figs., 1 tab. (Author)

  8. Enhanced CANDU 6 design assist probabilistic safety assessment results and insights

    International Nuclear Information System (INIS)

    Torabi, T.; Bettig, R.; Iliescu, P.; Robinson, J.; Santamaura, P.; Skorupska, B.; Tyagi, A.K.; Vencel, I.

    2013-01-01

    The Enhanced CANDU 6(EC6) is a 700 MWe reactor, which has evolved from the well-established CANDU line of reactors, which are heavy-water moderated, and heavy-water cooled horizontal pressure tube reactors, using natural uranium fuel. The EC6 design retains the generic CANDU design features, while incorporating innovations and state-of-the-art technologies to ensure competitiveness with other design with respect to operation, performance and economics. A design assist probabilistic safety assessment (PSA) was conducted during the design change phase of the project. The purpose of the assessment was to assess internal events during at-power operation and identify the design improvements and additional features needed to comply with the latest regulatory requirements in Canada and compete with other reactor designs, internationally. The PSA results show that the EC6 plant response to the postulated initiating events is well balanced, and the design meets its safety objectives. This paper summarizes the results and insights gained during the development of the PSA models for at-power internal events. (author)

  9. CATHENA Analysis Of Candu Advanced Passive Moderator Concept In Normal Operation Condition

    International Nuclear Information System (INIS)

    Alfa, Sudjatmi K

    2001-01-01

    In the CANDU - advanced passive moderator (APM) concept, the positive void reactivity is eliminated by reducing the density of the moderator. The simple model for the CANDU APM concept consists of the calandria, heat exchanger, pump, and a stabilizing tank, along with connecting piping. The calandria is divided into two parts, one part simulates the down area, while the other simulates up flow area. To demonstrate the thermalhydraulic behavior of the APM concept, Canadian algorithm for thermalhydraulic network analysis (CATHENA) code is used. The simulation for a pressure boundary condition of 300, 330 and 360 kPa and for water coolant mass flow rate boundary conditions of 2000 and 3000 kg/s respectively have been studied. Preliminary results show that there is boiling in the core, with vapor condensing in the heat exchanger. It is important to note, that the solution had not reached steady state when the boiling occurred

  10. Cobalt-60 production in CANDU power reactors

    International Nuclear Information System (INIS)

    Malkoske, G.R.; Norton, J.L.; Slack, J.

    2002-01-01

    MDS Nordion has been supplying cobalt-60 sources to industry for industrial and medical purposes since 1946. These cobalt-60 sources are used in many market and product segments, but are primarily used to sterilize single-use medical products including; surgical kits, gloves, gowns, drapes, and cotton swabs. Other applications include sanitization of cosmetics, microbial reduction of pharmaceutical raw materials, and food irradiation. The technology for producing the cobalt-60 isotope was developed by MDS Nordion and Atomic Energy of Canada Limited (AECL) almost 55 years ago using research reactors at the AECL Chalk River Laboratories in Ontario, Canada. The first cobalt-60 source produced for medical applications was manufactured by MDS Nordion and used in cancer therapy. The benefits of cobalt-60 as applied to medical product manufacturing, were quickly realized and the demand for this radioisotope quickly grew. The same technology for producing cobalt-60 in research reactors was then designed and packaged such that it could be conveniently transferred to a utility/power reactor. In the early 1970's, in co-operation with Ontario Power Generation (formerly Ontario Hydro), bulk cobalt-60 production for industrial irradiation applications was initiated in the four Pickering A CANDU reactors. As the demand and acceptance of sterilization of medical products grew, MDS Nordion expanded its bulk supply by installing the proprietary Canadian technology for producing cobalt-60 in additional CANDU reactors. CANDU is unique among the power reactors of the world, being heavy water moderated and fuelled with natural uranium. They are also designed and supplied with stainless steel adjusters, the primary function of which is to shape the neutron flux to optimize reactor power and fuel bum-up, and to provide excess reactivity needed to overcome xenon-135 poisoning following a reduction of power. The reactor is designed to develop full power output with all of the adjuster

  11. Development of CANDU advanced fuel bundle

    International Nuclear Information System (INIS)

    Suk, H. C.; Hwang, W.; Rhee, B. W.; Jung, S. H.; Chung, C. H.

    1992-05-01

    This research project is underway in cooperation with AECL to develop the CANDU advanced fuel bundle (so-called, CANFLEX) which can enhance reactor safety and fuel economy in comparison with the current CANDU fuel and which can be used with natural uranium, slightly enriched uranium and other advanced fuel cycle. As the final schedule, the advanced fuel will be verified by carrying out a large scale demonstration of the bundle irradiation in a commercial CANDU reactor for 1996 and 1997, and consequently will be used in the existing and future CANDU reactors in Korea. The research activities during this year include the detail design of CANFLEX fuel with natural enriched uranium (CANFLEX-NU). Based on this design, CANFLEX fuel was mocked up. Out-of-pile hydraulic scoping tests were conducted with the fuel in the CANDU Cold Test Loop to investigate the condition under which maximum pressure drop occurs and the maximum value of the bundle pressure drop. (Author)

  12. Transmutation of minor actinides in a Candu thorium borner

    International Nuclear Information System (INIS)

    Sahin, S.; Sahin, H. M.; Acir, A.; Yalcin, S.; Yildiz, K.; Sahin, N.; Altinok, T.; Alkan, M.

    2007-01-01

    The paper investigates the prospects of exploitation of rich world thorium reserves in CANDU reactors. Large quantities of plutonium have been accumulated in the nuclear waste of civilian LWRs and CANDU reactors. Reactor grade plutonium can be used as a booster fissile fuel material in form of mixed ThO 2 /PuO 2 fuel in a CANDU fuel bundle in order to assure reactor criticality. Two different fuel compositions have been selected for investigations: 1) 96% thoria (ThO 2 ) + 4% PuO 2 and 2) 91% ThO 2 + 5% UO 2 + 4 PuO 2 . The latter is used for the purpose of denaturing the new 2 33U fuel with 2 38U. The behavior of the criticality k ∞ and the burn-up values of the reactor have been pursued by full power operation for > ∼ 8 years. The reactor starts with k ∞ = ∼ 1.39 and the criticality drops down asymptotically to values k ∞ > 1.06, still tolerable and usable in a CANDU reactor. Reactor criticality k ∞ remains nearly constant between the 4th year and 7th year of plant operation and then a slight increase is observed thereafter, along with a continuous depletion of thorium fuel. After the 2nd year, the CANDU reactor begins to operate practically as a thorium burner. Very high burn up can be achieved with the same fuel (> 160 000 MW.D/MT). The reactor criticality would be sufficient until a great fraction of the thorium fuel is burnt up, provided that the fuel rods could be fabricated to withstand such high burn up levels. Fuel fabrication costs and nuclear waste mass for final disposal per unit energy could be reduced drastically. There is a great quantity of weapon grade plutonium accumulated in nuclear stockpiles. In the second phase of investigations, weapon grade plutonium is used as a booster fissile fuel material in form of mixed ThO 2 /PuO 2 fuel in a CANDU fuel bundle in order to assure the initial criticality at startup. Two different fuel compositions have been used: 1) 97% thoria (ThO 2 ) + 3% PuO 2 and 2) 92% ThO 2 + 5% UO 2 + 3% PuO 2 . The

  13. Development of first full scope commercial CANDU-6 fuel handling simulator

    Energy Technology Data Exchange (ETDEWEB)

    Crawford, W., E-mail: BCrawford@atlanticnuclear.ca [Atlantic Nuclear Services Inc., Fredericton, NB (Canada); McInerney, J. M., E-mail: JMcInerney@nbpower.com [Point Lepreau Generating Station, Maces Bay, NB (Canada); Moran, E.S.; Nice, J. W.; Sinclair, D.M.; Somerville, S.; Usalp, E.C.; Usalp, M., E-mail: EMoran@atlanticnuclear.ca, E-mail: JNice@atlanticnuclear.ca, E-mail: DSinclair@atlanticnuclear.ca, E-mail: SSomerville@atlanticnuclear.ca, E-mail: ECUsalp@atlanticnuclear.ca, E-mail: MUsalp@atlanticnuclear.ca [Atlantic Nuclear Services Inc., Fredericton, NB (Canada)

    2015-07-01

    Unique to CANDU reactors is continuous on-power refueling. In the CANDU-6 design, the fuel bundles are contained within 380 pressure tubes. Fuelling machines, one on either side of the reactor face move on a bridge and carriage system to the appointed channel and fuel under computer control. The fuelling machine is an immensely complicated mechanical device. None of the original Canadian full scope simulators incorporated the interaction of the fuel handling system. Traditionally, the final stages of Fuel Handling Operator qualification utilizes on the job training in a production environment carried out in the station main control room. For the purpose of supporting continual improvement in fuel handling training at the Third Qinshan Nuclear Plant Company (TQNPC), Atlantic Nuclear Services in a joint project with New Brunswick Power, developed the first commercial full scope CANDU-6 Fuel Handling simulator, integrated into the existing TQNPC Full Scope Simulator framework. The TQNPC Fuel Handling simulator is capable of supporting all normal on-power and off-power refuelling procedures as well as other abnormal operating conditions, which will allow training to be conducted, based on the plant specific operating procedures. This paper will discuss its development, the importance of this tool and its advantages over past training practices. (author)

  14. Development of first full scope commercial CANDU-6 fuel handling simulator

    International Nuclear Information System (INIS)

    Crawford, W.; McInerney, J. M.; Moran, E.S.; Nice, J. W.; Sinclair, D.M.; Somerville, S.; Usalp, E.C.; Usalp, M.

    2015-01-01

    Unique to CANDU reactors is continuous on-power refueling. In the CANDU-6 design, the fuel bundles are contained within 380 pressure tubes. Fuelling machines, one on either side of the reactor face move on a bridge and carriage system to the appointed channel and fuel under computer control. The fuelling machine is an immensely complicated mechanical device. None of the original Canadian full scope simulators incorporated the interaction of the fuel handling system. Traditionally, the final stages of Fuel Handling Operator qualification utilizes on the job training in a production environment carried out in the station main control room. For the purpose of supporting continual improvement in fuel handling training at the Third Qinshan Nuclear Plant Company (TQNPC), Atlantic Nuclear Services in a joint project with New Brunswick Power, developed the first commercial full scope CANDU-6 Fuel Handling simulator, integrated into the existing TQNPC Full Scope Simulator framework. The TQNPC Fuel Handling simulator is capable of supporting all normal on-power and off-power refuelling procedures as well as other abnormal operating conditions, which will allow training to be conducted, based on the plant specific operating procedures. This paper will discuss its development, the importance of this tool and its advantages over past training practices. (author)

  15. The CANDU 9 distributed control system design process

    International Nuclear Information System (INIS)

    Harber, J.E.; Kattan, M.K.; Macbeth, M.J.

    1997-01-01

    Canadian designed CANDU pressurized heavy water nuclear reactors have been world leaders in electrical power generation. The CANDU 9 project is AECL's next reactor design. Plant control for the CANDU 9 station design is performed by a distributed control system (DCS) as compared to centralized control computers, analog control devices and relay logic used in previous CANDU designs. The selection of a DCS as the platform to perform the process control functions and most of the data acquisition of the plant, is consistent with the evolutionary nature of the CANDU technology. The control strategies for the DCS control programs are based on previous CANDU designs but are implemented on a new hardware platform taking advantage of advances in computer technology. This paper describes the design process for developing the CANDU 9 DCS. Various design activities, prototyping and analyses have been undertaken in order to ensure a safe, functional, and cost-effective design. (author)

  16. ROP design for Enhanced CANDU 6 reactor

    Energy Technology Data Exchange (ETDEWEB)

    Hu, J.; Scherbakova, D; Kastanya, D.; Ovanes, M. [Candu Energy Inc., Mississauga, Ontario (Canada)

    2011-07-01

    The Enhanced CANDU 6 (EC6) nuclear power plant is a mid-sized pressurized heavy water reactor design, based on the highly successful CANDU 6 (C6) family of power plants, upgraded to meet today's Canadian and international safety requirements and to satisfy Generation III expectations. The EC6 reactor is equipped with two independent Regional Overpower Protection (ROP) systems to prevent overpowers in the reactor fuel. The ROP system design, retaining the traditional C6 methodology, is determined to cover the End-of-Life (EOL) reactor core condition since the reactor operating/thermal margin gradually decreases as plant equipment ages. Several design changes have been incorporated into the reference C6 plant to mitigate the ageing effect on the ROP trip margin. This paper outlines the basis for the EC6 ROP physics design and presents the ROP related improvements made in the EC6 design to ensure that full power operation is not limited by the ROP throughout the entire life of the reactor. (author)

  17. Proceedings of the fifth international conference on CANDU fuel. V.1,2

    International Nuclear Information System (INIS)

    Lau, J.H.

    1997-01-01

    The First International Conference on CANDU Fuel was held in Chalk River in 1986. The CANDU Fuel community has gathered every three years since. The papers presented include topics on international experience, CANFLEX fuel bundles, Fuel design, Fuel modelling, Manufacturing and Quality assurance, Fuel performance and Safety, Fuel cycles and Spent Fuel management. Volume One was published in advance of the conference and Volume Two was printed after the conference

  18. Proceedings of the fifth international conference on CANDU fuel. V.1,2

    Energy Technology Data Exchange (ETDEWEB)

    Lau, J H [ed.

    1997-07-01

    The First International Conference on CANDU Fuel was held in Chalk River in 1986. The CANDU Fuel community has gathered every three years since. The papers presented include topics on international experience, CANFLEX fuel bundles, Fuel design, Fuel modelling, Manufacturing and Quality assurance, Fuel performance and Safety, Fuel cycles and Spent Fuel management. Volume One was published in advance of the conference and Volume Two was printed after the conference.

  19. INR Recent Contributions to Thorium-Based Fuel Using in CANDU Reactors

    International Nuclear Information System (INIS)

    Prodea, I.; Mărgeanu, C. A.; Rizoiu, A.; Olteanu, G.

    2014-01-01

    The paper summarizes INR Pitesti contributions and latest developments to the Thorium-based fuel (TF) using in present CANDU nuclear reactors. Earlier studies performed in INR Pitesti revealed the CANDU design potential to use Recovered Uranium (RU) and Slightly Enriched Uranium (SEU) as alternative fuels in PHWRs. In this paper, we performed both lattice and CANDU core calculations using TF, revealing the main neutron physics parameters of interest: k-infinity, coolant void reactivity (CVR), channel and bundle power distributions over a CANDU 6 reactor core similar to that of Cernavoda, Unit 1. We modelled the so called Once Through Thorium (OTT) fuel cycle, using the 3D finite-differences DIREN code, developed in INR. The INR flexible SEU-43 bundle design was the candidate for TF carrying. Preliminary analysis regarding TF burning in CANDU reactors has been performed using the finite differences 3D code DIREN. TFs showed safety features improvement regarding lower CVRs in the case of fresh fuel use. Improvements added to the INR ELESIMTORIU- 1 computer code give the possibility to fairly simulate irradiation experiments in INR TRIGA research reactor. Efforts are still needed in order to get better accuracy and agreement of simulations to the experimental results. (author)

  20. An update on CANDU fuel channel performance

    International Nuclear Information System (INIS)

    Price, E.G.; Holt, R.A; Wong, H.; Gautheir, P.; Ellis, P.J.; Slade, J.

    1998-01-01

    Fuel channel components, particularly pressure tubes, are monitored to establish changes in their condition expected from their service environment. Such monitoring takes the form of the in-service NDE, in-service sampling and periodic tube removal for destructive examination. The pressure tubes in early CANDU 6 stations have now reached mid-life. The expected trends in behaviour of the various properties of the pressure tubes are being confirmed. Diametral deformation potentially limits the life of some pressure tubes, and fuel developments, such as the CANFLEX fuel bundle, will provide additional CHF margins. Corrosion and the associated deuterium pick-up are monitored to assess if any change in rates have occurred. Both have historically continued on an essentially linear trend with time. Recent data indicate that the rates of pick-up could be gradually increasing. Changes in mechanical properties, particularly toughness, have reached saturation levels. In the early reactors, the toughness is acceptable, assuring leak-before-break. The pressure tubes in later reactors have very low concentrations of chlorine and phosphorous and the level of hydrogen are also low, and these tubes are predicted to retain relativity high fracture toughness in-service. Debris fretting wear has occurred in CANDU reactors. Laboratory testing and experience show that no cracks have initiated from debris frets to date. Further debris fretting will have to be avoided by care in maintenance procedures, and existing defects must be monitored in the future as hydrogen concentration levels increase. Spacer location and repositioning (SLAR) has been necessary in earlier reactors with loose spacers. Procedures and equipment for SLAR have been developed and successfully applied. The efficiency of spacer relocation operations has improved with experience. (authors)

  1. CANDU steam generator tubing material service experience and allied development

    International Nuclear Information System (INIS)

    Hart, A.E.; Lesurf, J.E.

    1976-01-01

    This paper covers the following aspects for the tube materials in CANDU-PHW steam generators: inservice performance with respect to tube leaks and coolant activity attributable to boiler tube corrosion, selection of tube materials for use with non-boiling and boiling primary coolants, supporting development on corrosion, vibration, fretting wear, tube inspection, leak detection and plugging of defective tubes. (author)

  2. Conceptual designs for advanced, high-temperature CANDU reactors

    Energy Technology Data Exchange (ETDEWEB)

    Bushby, S.J. [Atomic Energy of Canada Ltd., Corrosion and Surface Science Branch, Chalk River Laboratories, Chalk River, ON (Canada); Dimmick, G.R. [Atomic Energy of Canada Ltd., Fuel Channel Thermmalhydraulics Branch, Chalk River, ON (Canada); Duffey, R.B. [Atomic Energy of Canada Ltd., Principal Scientist, Chalk River Laboratories, Chalk River, On (Canada); Spinks, N.J. [Atomic Energy of Canada Ltd., Researcher Emeritus, Chalk River Laboratories, Chalk River, ON (Canada); Burrill, K.A. [Atomic Energy of Canada Ltd., Chalk River Laboratories, Chalk River, ON (Canada); Chan, P.S.W. [Atomic Energy of Canada Ltd., Reactor Core Physics Branch, Mississauga, ON (Canada)

    2000-07-01

    AECL is studying advanced reactor concepts with the aim of significant cost reduction through improved thermodynamic efficiency and plant simplification. The program, generically called CANDU-X, also incorporates enhanced safety features, and flexible, proliferation-resistant fuel cycles, whilst retaining the fundamental design characteristics of CANDU: neutron economy, horizontal fuel channels, and a separate D{sub 2}O moderator that provides a passive heat sink. Where possible, proven, existing components and materials would be adopted, so that 'first-of-a-kind' costs and uncertainties are avoided. Three reactor concepts ranging in output from {approx}375 MW(e) to 1150 MW(e) are described. The modular design of a pressure tube reactor allows the plant size for each concept to be tailored to a given market through the addition or removal of fuel channels. Each concept uses supercritical water as the coolant at a nominal pressure of 25 MPa. Core outlet temperatures range from {approx}400degC to 625degC, resulting in substantial improvements in thermodynamic efficiencies compared to current nuclear stations. The CANDU-X Mark 1 concept is an extension of the present CANDU design. An indirect cycle is employed, but efficiency is increased due to higher coolant temperature, and changes to the secondary side; as well, the size and number of pumps and steam generators are reduced. Safety is enhanced through facilitation of thermo-siphoning of decay heat by increasing the temperature of the moderator. The CANDU-X NC concept is also based on an indirect cycle, but natural convection is used to circulate the primary coolant. This approach enhances cycle efficiency and safety, and is viable for reactors operating near the pseudo-critical temperature of water because of large changes in heat capacity and thermal expansion in that region. In the third concept (CANDUal-X), a dual cycle is employed. Supercritical water exits the core and feeds directly into a very high

  3. CANDU - a versatile reactor for plutonium disposition or actinide burning

    International Nuclear Information System (INIS)

    Chan, P.S.W.; Gagnon, M.J.N.; Boczar, P.G.; Ellis, R.J.; Verrall, R.A.

    1997-10-01

    High neutron economy, on-line refuelling, and a simple fuel-bundle design result in a high degree of versatility in the use of the CANDU reactor for the disposition of weapons-derived plutonium and for the annihilation of long-lived radioactive actinides, such as plutonium, neptunium, and americium isotopes, created in civilian nuclear power reactors. Inherent safety features are incorporated into the design of the bundles carrying the plutonium and actinide fuels. This approach enables existing CANDU reactors to operate with various plutonium-based fuel cycles without requiring major changes to the current reactor design. (author)

  4. Electrical, control and information systems in the Enhanced CANDU 6

    International Nuclear Information System (INIS)

    De Grosbois, J.; Raiskums, G.; Soulard, M.

    2011-01-01

    This paper describes the electrical, control, and information system (EC and I) design feature improvements of the Enhanced CANDU 6 (EC6). These additional features are carefully integrated into the EC6 design platform, and are engineered with consideration of operational feedback, human factors, and leveraging the advantages of digital instrumentation and control (I and C) technology to create a coherent I and C architecture in support of safe and high performance operation. The design drivers for the selection of advanced features are also discussed. The EC6 nuclear power plant is a mid-sized Pressurized Heavy Water Reactor design, based on the highly successful CANDU 6 family of power plants, and upgraded to meet today's Canadian and international safety requirements and to satisfy Generation 3 design expectations. (author)

  5. Study of candu fuel elements irradiated in a nuclear power plant

    International Nuclear Information System (INIS)

    Ionescu, S.; Uta, O.; Mincu, M.; Anghel, D.; Prisecaru, I.

    2015-01-01

    The object of this work is the behaviour of CANDU fuel elements after service in nuclear power plant. The results are analysed and compared with previous result obtained on unirradiated samples and with the results obtained on samples irradiated in the TRIGA reactor of INR Pitesti. Zircaloy-4 is the material used for CANDU fuel sheath. The importance of studying its behaviour results from the fact that the mechanical properties of the CANDU fuel sheath suffer modifications during normal and abnormal operation. In the nuclear reactor, the fuel elements endure dimensional and structural changes as well as cladding oxidation, hydriding and corrosion. These changes can lead to defects and even to the loss of integrity of the cladding. This paper presents the results of examinations performed in the Post Irradiation Examination Laboratory (PIEL) of INR Pitesti on samples from fuel elements after they were removed out of the nuclear power plant: - dimensional and macrostructural characterization; - microstructural characterization by metallographic analyses; - determination of mechanical properties; - fracture surface analysis by scanning electron microscopy (SEM). A full set of non-destructive and destructive examinations concerning the integrity, dimensional changes, oxidation, hydriding and mechanical properties of the cladding was performed. The obtained results are typical for CANDU 6-type fuel. The obtained data could be used to evaluate the security, reliability and nuclear fuel performance, and for the improvement of the CANDU fuel. (authors)

  6. New flux detectors for CANDU 6 reactors

    International Nuclear Information System (INIS)

    Cuttler, J.M.; Medak, N.

    1992-06-01

    CANDU reactors utilize large numbers of in-core self-powered detectors for control and protection. In the original design, the detectors (coaxial cables) were wound on carrier tubes and immersed in the heavy water moderator. Failures occurred due to corrosion and other factors, and replacement was very costly because the assemblies were not designed with maintenance in mind. A new design was conceived based on straight detectors, of larger diameter, in a sealed package of individual 'well' tubes. This protected the detectors from hostile environments and enabled individual failed sensors to be replaced by inserting spares in vacant neighbouring tubes. The new design was made retrofittable to older CANDU reactors. Provision was made for on-line scanning of the core with a miniature fission chamber. The modified detectors were tested in a lengthy development program and found to exhibit superior performance to that of the original detectors. Most of the CANDU reactors have now adopted the new design. In the case of the Gentilly-2 and Point Lepreau reactors, advantage was taken of the opportunity to redesign the detector layout (using better codes and the increased flexibility in positioning detectors) to achieve better coverage of abnormal events, leading to higher trip setpoints and wider operating margins

  7. Severe accident development modeling and evaluation for CANDU

    Energy Technology Data Exchange (ETDEWEB)

    Negut, Gheorghe [National Agency for Radioactive Waste, 1, Campului Str., 115400 Mioveni (Romania)], E-mail: gheorghe.negut@andrad.ro; Catana, Alexandru [Institute for Nuclear Research Pitesti, 1, Campului Str., Mioveni P.O. Box 78, 0300 Pitesti (Romania); Prisecaru, Ilie; Dupleac, Daniel [Politehnica University Bucharest, 313, Splaiul Independentei, Sect. 6, 060042 Bucharest (Romania)

    2009-09-15

    Romania as UE member got new challenges for its nuclear industry. Romania operates since 1996 a CANDU nuclear power reactor and since 2007 the second CANDU unit. In EU are operated mainly PWR reactors, so, ours have to meet UE standards. Safety analysis guidelines require to model nuclear reactors severe accidents. Starting from previous studies, a CANDU degraded core thermal hydraulic model was developed. The initiating event is a LOCA, with simultaneous loss of moderator cooling and the loss of emergency core cooling system (ECCS). This type of accident is likely to modify the reactor geometry and will lead to a severe accident development. When the coolant temperature inside a pressure tube reaches 1000 deg. C, a contact between pressure tube and calandria tube occurs and the decay heat is transferred to the moderator. Due to the lack of cooling, the moderator, eventually, begins to boil and is expelled, through the calandria vessel relief ducts, into the containment. Therefore the calandria tubes (fuel channels) uncover, then disintegrate and fall down to the calandria vessel bottom. All the quantity of calandria moderator is vaporized and expelled, the debris will heat up and eventually boil. The heat accumulated in the molten debris will be transferred through the calandria vessel wall to the shield tank water, which surrounds the calandria vessel. The thermal hydraulics phenomena described above are modeled, analyzed and compared with the existing data.

  8. Severe accident development modeling and evaluation for CANDU

    International Nuclear Information System (INIS)

    Negut, Gheorghe; Catana, Alexandru; Prisecaru, Ilie; Dupleac, Daniel

    2009-01-01

    Romania as UE member got new challenges for its nuclear industry. Romania operates since 1996 a CANDU nuclear power reactor and since 2007 the second CANDU unit. In EU are operated mainly PWR reactors, so, ours have to meet UE standards. Safety analysis guidelines require to model nuclear reactors severe accidents. Starting from previous studies, a CANDU degraded core thermal hydraulic model was developed. The initiating event is a LOCA, with simultaneous loss of moderator cooling and the loss of emergency core cooling system (ECCS). This type of accident is likely to modify the reactor geometry and will lead to a severe accident development. When the coolant temperature inside a pressure tube reaches 1000 deg. C, a contact between pressure tube and calandria tube occurs and the decay heat is transferred to the moderator. Due to the lack of cooling, the moderator, eventually, begins to boil and is expelled, through the calandria vessel relief ducts, into the containment. Therefore the calandria tubes (fuel channels) uncover, then disintegrate and fall down to the calandria vessel bottom. All the quantity of calandria moderator is vaporized and expelled, the debris will heat up and eventually boil. The heat accumulated in the molten debris will be transferred through the calandria vessel wall to the shield tank water, which surrounds the calandria vessel. The thermal hydraulics phenomena described above are modeled, analyzed and compared with the existing data.

  9. Computational fluid dynamics analysis for flow accelerated corrosion in CANDU6 feeder pipes

    International Nuclear Information System (INIS)

    Catana, A.; Pauna, E.; Ioan, M.

    2013-01-01

    CANDU6 plant management over a long time period includes various ageing and degradation mechanisms like FAC manifested mainly at first and second elbow of CANDU6 outlet feeders. FAC take place at all CANDU6 built before 2000 year with feeders made from SA106 grade B low alloy carbon-steel (with chromium at 0.02%). CFD method is used in this paper to investigate the feeder's wall thinning process taking place mainly due local flow conditions in complex 3D geometrical configurations. The 380 outlet feeders grouped in 2.5'' (320) and 2.0'' feeders (60). The objective of this paper is to help, as much as possible, to focus investigation on most probable maximum thinning rate locations through 3D distribution of some TH parameters. Application of CFD methods in CANDU6 nuclear reactors implies the knowledge of real plant operating data like: long term time averaged channel power and mass flow as well as temperature, pressure, pHa etc allowing the optimization and cost reduction of wall thinning monitoring process at CANDU6 nuclear power plants. (authors)

  10. Assessment of ASSERT-PV for prediction of critical heat flux in CANDU bundles

    International Nuclear Information System (INIS)

    Rao, Y.F.; Cheng, Z.; Waddington, G.M.

    2014-01-01

    Highlights: • Assessment of the new Canadian subchannel code ASSERT-PV 3.2 for CHF prediction. • CANDU 28-, 37- and 43-element bundle CHF experiments. • Prediction improvement of ASSERT-PV 3.2 over previous code versions. • Sensitivity study of the effect of CHF model options. - Abstract: Atomic Energy of Canada Limited (AECL) has developed the subchannel thermalhydraulics code ASSERT-PV for the Canadian nuclear industry. The recently released ASSERT-PV 3.2 provides enhanced models for improved predictions of flow distribution, critical heat flux (CHF), and post-dryout (PDO) heat transfer in horizontal CANDU fuel channels. This paper presents results of an assessment of the new code version against five full-scale CANDU bundle experiments conducted in 1990s and in 2009 by Stern Laboratories (SL), using 28-, 37- and 43-element (CANFLEX) bundles. A total of 15 CHF test series with varying pressure-tube creep and/or bearing-pad height were analyzed. The SL experiments encompassed the bundle geometries and range of flow conditions for the intended ASSERT-PV applications for CANDU reactors. Code predictions of channel dryout power and axial and radial CHF locations were compared against measurements from the SL CHF tests to quantify the code prediction accuracy. The prediction statistics using the recommended model set of ASSERT-PV 3.2 were compared to those from previous code versions. Furthermore, the sensitivity studies evaluated the contribution of each CHF model change or enhancement to the improvement in CHF prediction. Overall, the assessment demonstrated significant improvement in prediction of channel dryout power and axial and radial CHF locations in horizontal fuel channels containing CANDU bundles

  11. Development of the Advanced CANDU Reactor control centre

    International Nuclear Information System (INIS)

    Malcolm, S.; Leger, R.

    2004-01-01

    The next generation CANDU control centre is being designed for the Advanced CANDU Reactor (ACR) station. The design is based upon the recent Qinshan control room with further upgrades to meet customer needs with respect to high capacity factor with low Operation, Maintenance and Administration (OM and A) costs. This evolutionary design includes the long proven functionality at several existing CANDU control centres such as the 4-unit station at Darlington, with advanced features made possible by new control and display technology. Additionally, ACR control centres address characteristics resulting from Human Factors Engineering (HFE) analysis of control centre operations in order to further enhance personnel awareness of system and plant status. Statistics show that up to 70% of plant significant events, which have caused plant outages, have a root cause attributable to the human from such sources as complex interfaces, procedures, maintenance and management practices. Consequently, special attention is made for the application of HFE throughout the ACR design process. The design process follows a systematic analytical approach to define operations staff information and information presentation requirements. The resultant human-system interfaces (HSI) such as those for monitoring, annunciation and control information are then verified and validated against the system design requirements to provide a high confidence level that adequate and correct information is being provided in a timely manner to support the necessary operational tasks. The ACR control centre provides plant staff with an improved operability capability due to the combination of systematic design and enhanced operating features. Significant design processes (i.e. development) or design features which contribute to this improved operability, include: Design Process: Project HFE Program Plan - intent, scope, timeliness and interfacing; HFE aspects of design process - procedures and instructions

  12. Development of the advanced CANDU reactor control centre

    International Nuclear Information System (INIS)

    Malcolm, S.; Leger, R.

    2004-01-01

    The next generation CANDU control centre is being designed for the Advanced CANDU Reactor (ACR) station. The design is based upon the recent Qinshan control room with further upgrades to meet customer needs with respect to high capacity factor with low Operation, Maintenance and Administration (OM and A) costs. This evolutionary design includes the long proven functionality at several existing CANDU control centres such as the 4-unit station at Darlington, with advanced features made possible by new control and display technology. Additionally, ACR control centres address characteristics resulting from Human Factors Engineering (HFE) analysis of control centre operations in order to further enhance personnel awareness of system and plant status. Statistics show that up to 70% of plant significant events, which have caused plant outages, have a root cause attributable to the human from such sources as complex interfaces, procedures, maintenance and management practices. Consequently, special attention is made for the application of HFE throughout the ACR design process. The design process follows a systematic analytical approach to define operations staff information and information presentation requirements. The resultant human-system interfaces (HSI) such as those for monitoring, annunciation and control information are then verified and validated against the system design requirements to provide a high confidence level that adequate and correct information is being provided in a timely manner to support the necessary operational tasks. The ACR control centre provides plant staff with an improved operability capability due to the combination of systematic design and enhanced operating features. Significant design processes (i.e. development) or design features which contribute to this improved operability, include: Design Process: Project HFE Program Plan - intent, scope, timeliness and interfacing; HFE aspects of design process - procedures and instructions

  13. Subchannel flow analysis in Candu and ACR pressure tubes with radial and axial diameter variation

    Energy Technology Data Exchange (ETDEWEB)

    Catana, A.; Prodea, L. [RAAN, Institute for Nuclear Research, Arges (Romania); Danila, N.; Prisecaru, I.; Dupleac, D. [Bucharest Univ. Politehnica(Romania)

    2007-07-01

    The Candu (Canada Deuterium Uranium) and ACR (Advanced Candu Reactor) are pressure tubes (PT) heavy water moderated reactors. Candu are heavy water and ACR are light water cooled reactors. The pressure tube is filled with 12 bundles, each consisting of 37 respectively 43 fuel rods. One Candu reactor is in operation at Cernavoda, Romania since 1996. ACR is a proposed advanced Candu. PT diameter variation has a significant impact on the thermal-hydraulic parameters. Almost all thermal-hydraulic parameters change, but some of them have a greater significance. In this work we have considered a set of radial and axial PT diameter variations both for Candu-600 and ACR-700 reactors using various types of fuel bundles. We can conclude the following: 1) some thermal-hydraulic parameters are significantly influenced: critical heat flux (CHF), pressure drop, or void fraction; 2) the most significant parameter CHF is worsening which reduces the safety margin; 3) some fuel types present a better thermal-hydraulic behavior; and 4) fuel bundles with fresh fuel or low burnup have a worse thermal-hydraulic behaviour than those at average burn-up.

  14. Subchannel flow analysis in Candu and ACR pressure tubes with radial and axial diameter variation

    International Nuclear Information System (INIS)

    Catana, A.; Prodea, L.; Danila, N.; Prisecaru, I.; Dupleac, D.

    2007-01-01

    The Candu (Canada Deuterium Uranium) and ACR (Advanced Candu Reactor) are pressure tubes (PT) heavy water moderated reactors. Candu are heavy water and ACR are light water cooled reactors. The pressure tube is filled with 12 bundles, each consisting of 37 respectively 43 fuel rods. One Candu reactor is in operation at Cernavoda, Romania since 1996. ACR is a proposed advanced Candu. PT diameter variation has a significant impact on the thermal-hydraulic parameters. Almost all thermal-hydraulic parameters change, but some of them have a greater significance. In this work we have considered a set of radial and axial PT diameter variations both for Candu-600 and ACR-700 reactors using various types of fuel bundles. We can conclude the following: 1) some thermal-hydraulic parameters are significantly influenced: critical heat flux (CHF), pressure drop, or void fraction; 2) the most significant parameter CHF is worsening which reduces the safety margin; 3) some fuel types present a better thermal-hydraulic behavior; and 4) fuel bundles with fresh fuel or low burnup have a worse thermal-hydraulic behaviour than those at average burn-up

  15. Feasibility Study for Cobalt Bundle Loading to CANDU Reactor Core

    International Nuclear Information System (INIS)

    Park, Donghwan; Kim, Youngae; Kim, Sungmin

    2016-01-01

    CANDU units are generally used to produce cobalt-60 at Bruce and Point Lepreau in Canada and Embalse in Argentina. China has started production of cobalt-60 using its CANDU 6 Qinshan Phase III nuclear power plant in 2009. For cobalt-60 production, the reactor’s full complement of stainless steel adjusters is replaced with neutronically equivalent cobalt-59 adjusters, which are essentially invisible to reactor operation. With its very high neutron flux and optimized fuel burn-up, the CANDU has a very high cobalt-60 production rate in a relatively short time. This makes CANDU an excellent vehicle for bulk cobalt-60 production. Several studies have been performed to produce cobalt-60 using adjuster rod at Wolsong nuclear power plant. This study proposed new concept for producing cobalt-60 and performed the feasibility study. Bundle typed cobalt loading concept is proposed and evaluated the feasibility to fuel management without physics and system design change. The requirement to load cobalt bundle to the core was considered and several channels are nominated. The production of cobalt-60 source is very depend on the flux level and burnup directly. But the neutron absorption characteristic of cobalt bundle is too high, so optimizing design study is needed in the future

  16. Feasibility Study for Cobalt Bundle Loading to CANDU Reactor Core

    Energy Technology Data Exchange (ETDEWEB)

    Park, Donghwan; Kim, Youngae; Kim, Sungmin [KHNP Central Research Institute, Daejeon (Korea, Republic of)

    2016-10-15

    CANDU units are generally used to produce cobalt-60 at Bruce and Point Lepreau in Canada and Embalse in Argentina. China has started production of cobalt-60 using its CANDU 6 Qinshan Phase III nuclear power plant in 2009. For cobalt-60 production, the reactor’s full complement of stainless steel adjusters is replaced with neutronically equivalent cobalt-59 adjusters, which are essentially invisible to reactor operation. With its very high neutron flux and optimized fuel burn-up, the CANDU has a very high cobalt-60 production rate in a relatively short time. This makes CANDU an excellent vehicle for bulk cobalt-60 production. Several studies have been performed to produce cobalt-60 using adjuster rod at Wolsong nuclear power plant. This study proposed new concept for producing cobalt-60 and performed the feasibility study. Bundle typed cobalt loading concept is proposed and evaluated the feasibility to fuel management without physics and system design change. The requirement to load cobalt bundle to the core was considered and several channels are nominated. The production of cobalt-60 source is very depend on the flux level and burnup directly. But the neutron absorption characteristic of cobalt bundle is too high, so optimizing design study is needed in the future.

  17. CANDU reactors with reactor grade plutonium/thorium carbide fuel

    Energy Technology Data Exchange (ETDEWEB)

    Sahin, Suemer [Atilim Univ., Ankara (Turkey). Faculty of Engineering; Khan, Mohammed Javed; Ahmed, Rizwan [Pakistan Institute of Engineering and Applied Sciences, Islamabad (Pakistan); Gazi Univ., Ankara (Turkey). Faculty of Technology

    2011-08-15

    Reactor grade (RG) plutonium, accumulated as nuclear waste of commercial reactors can be re-utilized in CANDU reactors. TRISO type fuel can withstand very high fuel burn ups. On the other hand, carbide fuel would have higher neutronic and thermal performance than oxide fuel. In the present work, RG-PuC/ThC TRISO fuels particles are imbedded body-centered cubic (BCC) in a graphite matrix with a volume fraction of 60%. The fuel compacts conform to the dimensions of sintered CANDU fuel compacts are inserted in 37 zircolay rods to build the fuel zone of a bundle. Investigations have been conducted on a conventional CANDU reactor based on GENTILLYII design with 380 fuel bundles in the core. Three mixed fuel composition have been selected for numerical calculation; (1) 10% RG-PuC + 90% ThC; (2) 30% RG-PuC + 70% ThC; (3) 50% RG-PuC + 50% ThC. Initial reactor criticality values for the modes (1), (2) and (3) are calculated as k{sub {infinity}}{sub ,0} = 1.4848, 1.5756 and 1.627, respectively. Corresponding operation lifetimes are {proportional_to} 2.7, 8.4, and 15 years and with burn ups of {proportional_to} 72 000, 222 000 and 366 000 MW.d/tonne, respectively. Higher initial plutonium charge leads to higher burn ups and longer operation periods. In the course of reactor operation, most of the plutonium will be incinerated. At the end of life, remnants of plutonium isotopes would survive; and few amounts of uranium, americium and curium isotopes would be produced. (orig.)

  18. Enhanced CANDU 6 (EC6): a proven mid-sized reactor with fuel cycle capability

    International Nuclear Information System (INIS)

    Hopwood, J.; Soulard, M.; Hastings, I.J.

    2011-01-01

    Atomic Energy of Canada (AECL) is finalizing development of the Enhanced CANDU 6 (EC6), which incorporates the CANDU 6's well-proven features, and adds enhancements that make the reactor even more safe and easier to operate. The EC6 is the only mid-sized reactor (700 MWe class) with a proven pedigree that meets modern reactor expectations and regulatory standards. It is sized for smaller grids and also has outstanding fuel-cycle capability. Changes are incremental and consistent with the CANDU 6 project approach. The EC6 utilizes modern computers and a distributed control system housed in an advanced control room which, along with automated testing and on-line diagnostics, make the plant easier and safer to operate, with minimal operator intervention. Containment and seismic capability are upgraded to meet modern standards. The first deployment of the EC6 is anticipated in Canada; international markets are also being pursued. AECL is performing a comprehensive review of the EC6 design in the wake of the Fukushima accident, will review lessons learned, and incorporate any necessary improvements into new build design. (author)

  19. Enhanced CANDU 6 (EC6): a proven mid-sized reactor with fuel cycle capability

    International Nuclear Information System (INIS)

    Hopwood, J.; Soulard, M.; Hastings, I.J.

    2011-01-01

    Atomic Energy of Canada (AECL) is finalizing development of the Enhanced CANDU 6 (EC6), which incorporates the CANDU 6's well-proven features, and enhancements that make the reactor even more safe and easier to operate. The EC6 is the only mid-sized reactor (700 MWe class) with a proven pedigree that meets modern reactor expectations and regulatory standards. It is sized for smaller grids and also has outstanding fuel-cycle capability. Changes are incremental and consistent with the CANDU 6 project approach. The EC6 utilizes modern computers and a distributed control system housed in an advanced control room which, along with automated testing and on-line diagnostics, make the plant easier and safer to operate, with minimal operator intervention. Containment and seismic capability are upgraded to meet modern standards. The first deployment of the EC6 is anticipated in Canada; international markets are also being pursued. AECL is performing a comprehensive review of the EC6 design in the wake of the Fukushima accident, will review lessons learned, and incorporate any necessary improvements into new build design. (author)

  20. Ninth international conference on CANDU fuel, 'fuelling a clean future'

    International Nuclear Information System (INIS)

    2005-01-01

    The Canadian Nuclear Society's 9th International Conference on CANDU fuel took place in Belleville, Ontario on September 18-21, 2005. The theme for this year's conference was 'Fuelling a Clean Future' bringing together over 80 delegates ranging from: designers, engineers, manufacturers, researchers, modellers, safety specialists and managers to share the wealth of their knowledge and experience. This international event took place at an important turning point of the CANDU technology when new fuel design is being developed for commercial application, the Advanced CANDU Reactor is being considered for projects and nuclear power is enjoying a renaissance as the source energy for our future. Most of the conference was devoted to the presentation of technical papers in four parallel sessions. The topics of these sessions were: Design and Development; Fuel Safety; Fuel Modelling; Fuel Performance; Fuel Manufacturing; Fuel Management; Thermalhydraulics; and, Spent Fuel Management and Criticalty

  1. Remote handling equipment for CANDU retubing

    International Nuclear Information System (INIS)

    Crawford, G.S.; Lowe, H.

    1993-01-01

    Numet Engineering Ltd. has designed and supplied remote handling equipment for Ontario Hydro's retubing operation of its CANDU reactors at the Bruce Nuclear Generating Station. This equipment consists of ''Retubing Tool Carriers'' an'' Worktables'' which operate remotely or manually at the reactor face. Together they function to transport tooling to and from the reactor face, to position and support tooling during retubing operations, and to deliver and retrieve fuel channels and channel components. This paper presents the fundamentals of the process and discusses the equipment supplied in terms of its design, manufacturing, components and controls, to meet the functional and quality requirements of Ontario Hydro's retubing process. (author)

  2. CANDU development

    International Nuclear Information System (INIS)

    Brooks, G.L.

    1981-06-01

    Evolution of the 950 MW(e) CANDU reactor is summarized. The design was specifically aimed at the export market. Factors considered in the design were that 900-1000 MW is the maximum practical size for most countries; many countries have warmer condenser cooling water than Canada; the plant may be located on coastal sites; seismic requirements may be more stringent; and the requirements of international, as well as Canadian, standards must be satisfied. These considerations resulted in a 600-channel reactor capable of accepting condenser cooling water at 32 0 C. To satisfy the requirement for a proven design, the 950 MW CANDU draws upon the basic features of the Bruce and Pickering plants which have demonstrated high capacity factors

  3. The Candu system - The way for nuclear autonomy

    International Nuclear Information System (INIS)

    Martinez, H.

    1987-01-01

    The experience acquired by Canada during the development of Candu System is presented. Some basic foundations of technology transfer are defined and, the conditions of canadian nuclear industry to provide developing countries, technical assistence for acquisition of nuclear energy autonomy, are analysed. (M.C.K.) [pt

  4. CANDU fuel bundle deformation modelling with COMSOL multiphysics

    International Nuclear Information System (INIS)

    Bell, J.S.; Lewis, B.J.

    2012-01-01

    Highlights: ► The deformation behaviour of a CANDU fuel bundle was modelled. ► The model has been developed on a commercial finite-element platform. ► Pellet/sheath interaction and end-plate restraint effects were considered. ► The model was benchmarked against the BOW code and a variable-load experiment. - Abstract: A model to describe deformation behaviour of a CANDU 37-element bundle has been developed under the COMSOL Multiphysics finite-element platform. Beam elements were applied to the fuel elements (composed of fuel sheaths and pellets) and endplates in order to calculate the bowing behaviour of the fuel elements. This model is important to help assess bundle-deformation phenomena, which may lead to more restrictive coolant flow through the sub-channels of the horizontally oriented bundle. The bundle model was compared to the BOW code for the occurrence of a dry-out patch, and benchmarked against an out-reactor experiment with a variable load on an outer fuel element.

  5. Validation of the COBRA code for dry out power calculation in CANDU type advanced fuels

    International Nuclear Information System (INIS)

    Daverio, Hernando J.

    2003-01-01

    Stern Laboratories perform a full scale CHF testing of the CANFLEX bundle under AECL request. This experiment is modeled with the COBRA IV HW code to verify it's capacity for the dry out power calculation . Good results were obtained: errors below 10 % with respect to all data measured and 1 % for standard operating conditions in CANDU reactors range . This calculations were repeated for the CNEA advanced fuel CARA obtaining the same performance as the CANFLEX fuel. (author)

  6. Development of Realistic Safety Analysis Technology for CANDU Reactors

    International Nuclear Information System (INIS)

    Park, Joo Hwan; Rhee, B. W.; Rho, G. H.

    2010-04-01

    The following 3 research items have been studied to develop and establish the realistic safety analysis and the associated technologies for a CANDU reactor. At the first, WIMS-CANDU which is physics cell code for a CANDU has been improved and validated against the physics criticality experiment data transferred through the international cooperation programs. Also an improved physics model to take into account the pressure tube creep was developed and utilized to assess the effects of the pressure tube creep of 0%, 2.5% and 5% diametral increase of pressure tube on core physics parameters. Secondly, the interfacing module between physics and thermal-hydraulics codes has been developed to provide the enhancement of reliability and convenience of the calculation results of the physics parameters such as power coefficient which was calculated by independent code systems. Finally, the important parameters related to the complex heat transfer mechanisms in the crept pressure tubes were identified to find how to improve the existing fuel channel models. One of the important parameters such as the oxidation model of Zr-steam reaction was identified, implemented and verified with the experimental data of the high pressure and temperature fuel channel and its model was utilized for CFD analysis of the crept pressure tube effect on the reactor safety. The results were also provided to validate the CATNENA models of the crept pressure tube and the effects of the pressure tube creep on the blowdown and post-blowdown phase during LOCA was assessed. The results of this study can be used to assess the uncertainty analysis of coolant void reactivity and the effects of the creep deformed pressure tubes on physics/TH/safety issues. Also, those results will be used to improve the current design and operational safety analysis codes, and to technically support the related issues to resolve their problems

  7. Subchannel analysis code development for CANDU fuel channel

    International Nuclear Information System (INIS)

    Park, J. H.; Suk, H. C.; Jun, J. S.; Oh, D. J.; Hwang, D. H.; Yoo, Y. J.

    1998-07-01

    Since there are several subchannel codes such as COBRA and TORC codes for a PWR fuel channel but not for a CANDU fuel channel in our country, the subchannel analysis code for a CANDU fuel channel was developed for the prediction of flow conditions on the subchannels, for the accurate assessment of the thermal margin, the effect of appendages, and radial/axial power profile of fuel bundles on flow conditions and CHF and so on. In order to develop the subchannel analysis code for a CANDU fuel channel, subchannel analysis methodology and its applicability/pertinence for a fuel channel were reviewed from the CANDU fuel channel point of view. Several thermalhydraulic and numerical models for the subchannel analysis on a CANDU fuel channel were developed. The experimental data of the CANDU fuel channel were collected, analyzed and used for validation of a subchannel analysis code developed in this work. (author). 11 refs., 3 tabs., 50 figs

  8. Nuclear safety risk control in the outage of CANDU unit

    International Nuclear Information System (INIS)

    Wu Mingliang; Zheng Jianhua

    2014-01-01

    Nuclear fuel remains in the core during the outage of CANDU unit, but there are still nuclear safety risks such as reactor accidental criticality, fuel element failure due to inability to properly remove residual heat. Furthermore, these risks are aggravated by the weakening plant system configuration and multiple cross operations during the outage. This paper analyzes the phases where there are potential nuclear safety risks on the basis of the typical critical path arrangement of the outage of Qinshan NPP 3 and introduces a series of CANDU-specific risk control measures taken during the past plant outages to ensure nuclear safety during the unit outage. (authors)

  9. CANDU fuel cycle economic efficiency assessments using the IAEA-MESSAGE-V code

    International Nuclear Information System (INIS)

    Prodea, Iosif; Margeanu, Cristina Alice; Aioanei, Corina; Prisecaru, Ilie; Danila, Nicolae

    2007-01-01

    The main goal of the paper is to evaluate different electricity generation costs in a CANDU Nuclear Power Plant (NPP) using different nuclear fuel cycles. The IAEA-MESSAGE code (Model for Energy Supply Strategy Alternatives and their General Environmental Impacts) will be used to accomplish these assessments. This complex tool was supplied by International Atomic Energy Agency (IAEA) in 2002 at 'IAEA-Regional Training Course on Development and Evaluation of Alternative Energy Strategies in Support of Sustainable Development' held in Institute for Nuclear Research Pitesti. It is worthy to remind that the sustainable development requires satisfying the energy demand of present generations without compromising the possibility of future generations to meet their own needs. Based on the latest public information in the next 10-15 years four CANDU-6 based NPP could be in operation in Romania. Two of them will have some enhancements not clearly specified, yet. Therefore we consider being necessary to investigate possibility to enhance the economic efficiency of existing in-service CANDU-6 power reactors. The MESSAGE program can satisfy these requirements if appropriate input models will be built. As it is mentioned in the dedicated issues, a major inherent feature of CANDU is its fuel cycle flexibility. Keeping this in mind, some proposed CANDU fuel cycles will be analyzed in the paper: Natural Uranium (NU), Slightly Enriched Uranium (SEU), Recovered Uranium (RU) with and without reprocessing. Finally, based on optimization of the MESSAGE objective function an economic hierarchy of CANDU fuel cycles will be proposed. The authors used mainly public information on different costs required by analysis. (authors)

  10. A New In-core Production Method of Co-60 in CANDU Reactors

    Energy Technology Data Exchange (ETDEWEB)

    Lyu, Jinqi; Kim, Woosong; Kim, Yonghee [KAIST, Daejeon (Korea, Republic of); Park, Younwon [BEES Inc, Daejeon (Korea, Republic of)

    2016-05-15

    This study introduces an innovative method for Co-60 production in the CANDU6 core. In this new scheme, the central fuel element is replaced by a Co-59 target and Co-60 is obtained after the fuel bundle is discharged. It has been shown that the new method can produce significantly higher amount of Co-60 than the conventional Co production method in CANDU6 reactors without compromising the fuel burnup by removing some (<50%) of the adjuster rods in the whole core. The coolant void reactivity is noticeably reduced when a Co-59 target is loaded into the central pin of the fuel bundle. Meanwhile, the peak power in a fuel bundle is just a little higher due to the central Co-59 target than in conventional CANDU6 fuel design. The basic technology for Co-60 producing was developed by MDS Nordion and Atomic Energy of Canada Limited (AECL) in 1946 and the same technology was adapted and applied in CANDU6 power reactors. The standard CANDU6 reactor has 21 adjuster rods which are fully inserted into the core during normal operation. The stainless steel adjuster rods are replaced with neutronically-equivalent Co-59 adjusters to produce Co-60. Nowadays, the roles of the adjuster rods are rather vague since nuclear reactors cannot be quickly restarted after a sudden reactor trip due to more stringent regulations. In some Canadian CANDU6 reactors, some or all the adjuster rods are removed from the core to maximize the uranium utilization.

  11. CANDU-9/480-SEU fuel handling system assessment document

    International Nuclear Information System (INIS)

    Hwang, Jeong Ki; Jo, C. H.; Kim, H. M.; Morikawa, D. T.

    1996-11-01

    This report summarize the rationale for the CANDU 9 fuel handling system, and the design choices recommended for components of the system. Some of the design requirements applicable to the CANDU 9 480-SEU fuel handling design choices are described. These requirements imposed by the CANDU 9 project. And the design features for the key components of fuel handling system, such as the fuelling machine, the carriage, the new fuel transfer system and the irradiated fuel transfer system, are described. The carriage seismic load evaluations relevant to the design are contained in the appendices. The majority of the carriage components are acceptable, or will likely be acceptable with some redesign. The concept for the CANDU 9 fuel handling system is based on proven CANDU designs, or on improved CANDU technology. Although some development work must be done, the fuel handling concept is judged to be feasible for the CANDU 9 480-SEU reactor. (author). 2 refs

  12. Reactors based on CANDU technology

    International Nuclear Information System (INIS)

    Bjegun, S.V.; Shirokov, S.V.

    2012-01-01

    The paper analyzes the use CANDU technology in world nuclear energy. Advantages and disadvantages in implementation of this technology are considered in terms of economic and technical aspects. Technological issues related to the use of CANDU reactors and nuclear safety issues are outlined. Risks from implementation of this reactor technology in nuclear energy of Ukraine are determined

  13. A feasible approach to implement a commercial scale CANDU fuel manufacturing plant in Egypt

    International Nuclear Information System (INIS)

    El-Shehawy, I.; El-Sharaky, M.; Yasso, K.; Selim, I.; Graham, N.; Newington, D.

    1995-01-01

    Many planning scenarios have been examined to assess and evaluate the economic estimates for implementing a commercial scale CANDU fuel manufacturing plant in Egypt. The cost estimates indicated strong influence of the annual capital costs on total fuel manufacturing cost; this is particularly evident in a small initial plant where the proposed design output is only sufficient to supply reload fuel for a single CANDU-6 reactor. A modular approach is investigated as a possible way, to reduce the capital costs for a small initial fuel plant. In this approach the plant would do fuel assembly operations only and the remainder of a plant would be constructed and equipped in the stages when high production volumes can justify the capital expenses. Such approach seems economically feasible for implementing a small scale CANDU fuel manufacturing plant in developing countries such as Egypt and further improvement could be achieved over the years of operation. (author)

  14. 9th International conference on CANDU maintenance

    International Nuclear Information System (INIS)

    2011-01-01

    The 9th International Conference on CANDU Maintenance was held in Toronto, Ontario, Canada on December 4-6, 2011. The conference focused on Nuclear plant reliability and maintenance. Equipment reliability is a critical factor in achieving safe and reliable Nuclear Power Plant operations for many reasons. For one it reduces the challenges upon the operating staff and allows station personnel to 'go on the offence' instead of having to play defense in a reactive mode. Plant reliability ensures that there is time to study the issues in detail and develop solutions for long-term success. Let us not forget that the owner carries the burden of demonstrating the return on investment, and plant reliability goes a long way in helping to make the case for plant life extension. A good reputation for plant reliability provides the public capital necessary to build confidence and facilitate the licensing process. The proceedings papers and presentations given at the 9th International Conference on Candu Maintenance covered topics that include: Managing Worker; Radiation Dose; Full Life Cycle Management; Managing Maintenance Refurbishment; Designing for Maintainability; Inspection Techniques; and, Mitigating Degradation.

  15. CANDU plant life management - An integrated approach

    International Nuclear Information System (INIS)

    Hopkins, J.R.

    1998-01-01

    An integrated approach to plant life management has been developed for CANDU reactors. Strategies, methods, and procedures have been developed for assessment of critical systems structures and components and for implementing a reliability centred maintenance program. A Technology Watch program is being implemented to eliminate 'surprises'. Specific work has been identified for 1998. AECL is working on the integrated program with CANDU owners and seeks participation from other CANDU owners

  16. CANDU: Meeting the demand for energy self-sufficiency

    International Nuclear Information System (INIS)

    Lawson, D.S.

    1985-01-01

    The success of the CANDU program can been seen quickly by examining the comparison of typical electricity bills in various provinces of Canada. The provinces of Quebec and Manitoba benefit b extensive hydro electric schemes, many of which were constructed years ago at low capital cost. In Ontario, the economic growth has outstripped these low cost sources of hydro power and hence the province has to rely on thermal sources of electricity generation. The success of the CANDU program is shown by the fact that it can contribute over a third of electricity in Ontario while keeping the total electricity rate comparable with that of those provinces that can rely on low cost hydro sources. Energy self-sufficiency encompasses a spectrum of requirements. One consideration would be the reliable supply and control of fuel during the operating life of a power plant: A greater degree of self-sufficiency would be obtained by having an involvement in the building and engineering of the power plant prior to its operation

  17. Assessment of ASSERT-PV for prediction of post-dryout heat transfer in CANDU bundles

    International Nuclear Information System (INIS)

    Cheng, Z.; Rao, Y.F.; Waddington, G.M.

    2014-01-01

    Highlights: • Assessment of the new Canadian subchannel code ASSERT-PV 3.2 for PDO sheath temperature prediction. • CANDU 28-, 37- and 43-element bundle PDO experiments. • Prediction improvement of ASSERT-PV 3.2 over previous code versions. • Sensitivity study of the effect of PDO model options. - Abstract: Atomic Energy of Canada Limited (AECL) has developed the subchannel thermalhydraulics code ASSERT-PV for the Canadian nuclear industry. The recently released ASSERT-PV 3.2 provides enhanced models for improved predictions of subchannel flow distribution, critical heat flux (CHF), and post-dryout (PDO) heat transfer in horizontal CANDU fuel channels. This paper presents results of an assessment of the new code version against PDO tests performed during five full-size CANDU bundle experiments conducted between 1992 and 2009 by Stern Laboratories (SL), using 28-, 37- and 43-element bundles. A total of 10 PDO test series with varying pressure-tube creep and/or bearing-pad height were analyzed. The SL experiments encompassed the bundle geometries and range of flow conditions for the intended ASSERT-PV applications for existing CANDU reactors. Code predictions of maximum PDO fuel-sheath temperature were compared against measurements from the SL PDO tests to quantify the code's prediction accuracy. The prediction statistics using the recommended model set of ASSERT-PV 3.2 were compared to those from previous code versions. Furthermore, separate-effects sensitivity studies quantified the contribution of each PDO model change or enhancement to the improvement in PDO heat transfer prediction. Overall, the assessment demonstrated significant improvement in prediction of PDO sheath temperature in horizontal fuel channels containing CANDU bundles

  18. Mobile robotics for CANDU maintenance

    International Nuclear Information System (INIS)

    Lipsett, M.G.; Rody, K.H.

    1996-01-01

    Although robotics researchers have been promising that robotics would soon be performing tasks in hazardous environments, the reality has yet to live up to the hype. The presently available crop of robots suitable for deployment in industrial situations are remotely operated, requiring skilled users. This talk describes cases where mobile robots have been used successfully in CANDU stations, discusses the difficulties in using mobile robots for reactor maintenance, and provides near-term goals for achievable improvements in performance and usefulness. (author) 5 refs., 2 ills

  19. Tritium inventory prediction in a CANDU plant

    International Nuclear Information System (INIS)

    Song, M.J.; Son, S.H.; Jang, C.H.

    1995-01-01

    The flow of tritium in a CANDU nuclear power plant was modeled to predict tritium activity build-up. Predictions were generally in good agreement with field measurements for the period 1983--1994. Fractional contributions of coolant and moderator systems to the environmental tritium release were calculated by least square analysis using field data from the Wolsong plant. From the analysis, it was found that: (1) about 94% of tritiated heavy water loss came from the coolant system; (2) however, about 64% of environmental tritium release came from the moderator system. Predictions of environmental tritium release were also in good agreement with field data from a few other CANDU plants. The model was used to calculate future tritium build-up and environmental tritium release at Wolsong site, Korea, where one unit is operating and three more units are under construction. The model predicts the tritium inventory at Wolsong site to increase steadily until it reaches the maximum of 66.3 MCi in the year 2026. The model also predicts the tritium release rate to reach a maximum of 79 KCi/yr in the year 2012. To reduce the tritium inventory at Wolsong site, construction of a tritium removal facility (TRF) is under consideration. The maximum needed TRF capacity of 8.7 MCi/yr was calculated to maintain tritium concentration effectively in CANDU reactors

  20. The water chemistry of CANDU PHW reactors

    International Nuclear Information System (INIS)

    LeSurf, J.E.

    1978-01-01

    This review will discuss the chemistry of the three major water circuits in a CANDU-PHW reactor, viz., the Primary Heat Transport (PHT) water, the moderator and the boiler water. An important consideration for the PHT chemistry is the control of corrosion and of the transport of corrosion products to minimize the growth of radiation fields. In new reactors the PHT will be allowed to boil, requiring reconsideration of the methods used to radiolytic oxygen and elevate the pH. Separation of the moderator from the PHT in the pressure-tubed CANDU design permits better optimization of the chemistry of each system, avoiding the compromises necessary when the same water serves both functions. Major objectives in moderator chemistry are to control (a) the radiolytic decomposition of D 2 0; (b) the concentration of soluble neutron poisons added to adjust reactivity; and (c) the chemistry of shutdown systems. The boiler water and its feed water are treated to avoid boiler tube corrosion, both during normal operation and when perturbations are caused to the feed by, for example, leaks in the condenser tubes which permit ingress of untreated condenser cooling water. Development of a system for automatic analysis and control of feed water to give rapid, reliable response to abnormal conditions is a novel feature which has been developed for incorporation in future CANDU-PHW reactors. (author)

  1. Development of the advanced PHWR technology -Verification tests for CANDU advanced fuel-

    Energy Technology Data Exchange (ETDEWEB)

    Jung, Jang Hwan; Suk, Hoh Chun; Jung, Moon Kee; Oh, Duk Joo; Park, Joo Hwan; Shim, Kee Sub; Jang, Suk Kyoo; Jung, Heung Joon; Park, Jin Suk; Jung, Seung Hoh; Jun, Ji Soo; Lee, Yung Wook; Jung, Chang Joon; Byun, Taek Sang; Park, Kwang Suk; Kim, Bok Deuk; Min, Kyung Hoh [Korea Atomic Energy Research Institute, Taejon (Korea, Republic of)

    1995-07-01

    This is the `94 annual report of the CANDU advanced fuel verification test project. This report describes the out-of pile hydraulic tests at CANDU-hot test loop for verification of CANFLEX fuel bundle. It is also describes the reactor thermal-hydraulic analysis for thermal margin and flow stability. The contents in this report are as follows; (1) Out-of pile hydraulic tests for verification of CANFLEX fuel bundle. (a) Pressure drop tests at reactor operation condition (b) Strength test during reload at static condition (c) Impact test during reload at impact load condition (d) Endurance test for verification of fuel integrity during life time (2) Reactor thermal-hydraulic analysis with CANFLEX fuel bundle. (a) Critical channel power sensitivity analysis (b) CANDU-6 channel flow analysis (c) Flow instability analysis. 61 figs, 29 tabs, 21 refs. (Author).

  2. Development of the advanced PHWR technology -Verification tests for CANDU advanced fuel-

    International Nuclear Information System (INIS)

    Jung, Jang Hwan; Suk, Hoh Chun; Jung, Moon Kee; Oh, Duk Joo; Park, Joo Hwan; Shim, Kee Sub; Jang, Suk Kyoo; Jung, Heung Joon; Park, Jin Suk; Jung, Seung Hoh; Jun, Ji Soo; Lee, Yung Wook; Jung, Chang Joon; Byun, Taek Sang; Park, Kwang Suk; Kim, Bok Deuk; Min, Kyung Hoh

    1995-07-01

    This is the '94 annual report of the CANDU advanced fuel verification test project. This report describes the out-of pile hydraulic tests at CANDU-hot test loop for verification of CANFLEX fuel bundle. It is also describes the reactor thermal-hydraulic analysis for thermal margin and flow stability. The contents in this report are as follows; (1) Out-of pile hydraulic tests for verification of CANFLEX fuel bundle. (a) Pressure drop tests at reactor operation condition (b) Strength test during reload at static condition (c) Impact test during reload at impact load condition (d) Endurance test for verification of fuel integrity during life time (2) Reactor thermal-hydraulic analysis with CANFLEX fuel bundle. (a) Critical channel power sensitivity analysis (b) CANDU-6 channel flow analysis (c) Flow instability analysis. 61 figs, 29 tabs, 21 refs. (Author)

  3. Privatize Candu (question mark)

    International Nuclear Information System (INIS)

    Kelly, Thomas.

    1981-01-01

    A report sponsored by a group of nuclear suppliers and the Royal Bank suggested that the Candu reactor system would sell better if it were owned by a private company. Licensing of a Candu reactor in the U.S.A. was also suggested. The author of this article agrees with these points, but disagrees with the suggestion that safeguards should be relaxed. He suggests that contracts should stipulate that instrumentation should be supplied as much as possible from Canadian sources

  4. Recent IAEA activities on CANDU-PHWR fuels and fuel cycles

    International Nuclear Information System (INIS)

    Inozemtsev, V.; Ganguly, C.

    2005-01-01

    Pressurized Heavy Water Reactors (PHWR), widely known as CANDU, are in operation in Argentina, Canada, China, India, Pakistan, Republic of Korea and Romania and account for about 6% of the world's nuclear electricity production. The CANDU reactor and its fuel have several unique features, like horizontal calandria and coolant tubes, on-power fuel loading, thin-walled collapsible clad coated with graphite on the inner surface, very high density (>96%TD) natural uranium oxide fuel and amenability to slightly enriched uranium oxide, mixed uranium plutonium oxide (MOX), mixed thorium plutonium oxide, mixed thorium uranium (U-233) oxide and inert matrix fuels. Several Technical Working Groups (TWG) of IAEA periodically discuss and review CANDU reactors, its fuel and fuel cycle options. These include TWGs on water-cooled nuclear power reactor Fuel Performance and Technology (TWGFPT), on Nuclear Fuel Cycle Options and spent fuel management (TWGNFCO) and on Heavy Water Reactors (TWGHWR). In addition, IAEA-INPRO project also covers Advanced CANDU Reactors (ACR) and DUPIC fuel cycles. The present paper summarises the Agency's activities in CANDU fuel and fuel cycle, highlighting the progress during the last two years. In the past we saw HWR and LWR technologies and fuel cycles separate, but nowadays their interaction is obviously growing, and their mutual influence may have a synergetic character if we look at the world nuclear fuel cycle as at an integrated system where the both are important elements in line with fast neutron, gas cooled and other advanced reactors. As an international organization the IAEA considers this challenge and makes concrete steps to tackle it for the benefit of all Member States. (author)

  5. Standard compliance - NDE performance demonstration/inspection in the CANDU industry

    International Nuclear Information System (INIS)

    Choi, E.

    2011-01-01

    CANDU nuclear power plants are operated in 3 provinces in Canada for electric power generation. A table in the paper will show the built and operating plants in Ontario, Quebec, New Brunswick and overseas. The regulator for nuclear power in Canada is the Canadian Nuclear Safety Commission (CNSC). The CNSC holds the plant licensees accountable for compliance to CSA N285.4 for periodic inspections. The Standard basically specifies the 'what, when, where, how, how much and how frequently' NDE is to be done on pressure retaining systems and components in CANDU nuclear power plants. In inspection methods, the Standard specifies they must be non-destructive. The NDE methods were grouped into visual, dimensional, surface, volumetric and integrative. The Standard also specifies that the licensees are responsible for the performance demonstration (PD) of the adequacy of the procedures and the proficiency of the personnel. This paper describes the Standard's requirement in NDE qualification and presents a joint project participated by Canadian and overseas CANDU owners. The sub-project for NDE included providing evidence and technical justification on the adequacy of the procedures and the proficiency of the personnel. The paper describes the qualification methodology followed by the participants. This will be followed by how the participants produced Inspection Specification, tools and procedures, personnel training and qualification programs, test and qualification samples, independent peer reviews and Technical Justification. (author)

  6. Two CANDU fueling machines tested at the Institute For Nuclear Research - Pitesti

    International Nuclear Information System (INIS)

    Doca, Cezar; Cojocaru, Virgil

    2005-01-01

    In 2003, as a national and European premiere, at the Institute for Nuclear Research Pitesti (INR), the Fueling Machine Head no.4 (F/M) for the Nuclear Power Plant Cernavoda - Unit 2 was successfully tested. In 2005, a second Fueling Machine (no.5) was tested for the Nuclear Power Plant Cernavoda - Unit 2. The Institute's main objective is to develop scientific and technological support for the Romanian Nuclear Power Program. Testing the Fueling Machines at INR Pitesti is part of the overall program to assimilate in Romania the CANDU technology. To perform the tests of these machines at INR Pitesti, a special testing rig was built and is available for this goal. Both the testing rig and staff had successfully assessed by the AECL representatives during two missions. There was a delivery contract between GEC Canada and Nuclear Power Plant Cernavoda - Unit 2 to provide the Fueling Machines no. 4 and no. 5 in Romania before testing operation. As a first conclusion, the Institute for Nuclear Research Pitesti has the facilities, the staff and the experience to perform possible co-operations with any other CANDU Reactor owner. This experience will support the next steps concerning F/M commissioning in the NPP Cernavoda - Unit 2 and also give the confidence to the end-users that the Institute's team can provide technical assistance during the operation. Also, the obtained results demonstrate that the overall refurbishment of the F/M control system in Unit 1 and Unit 2 will be possible. The paper presents: - a short description of the F/M head;- a short description of the F/M test rig; - the computer control system; - the F/M testing activities; -results and expectations. (authors)

  7. Two CANDU fueling machines tested at the Institute For Nuclear Research - Pitesti

    International Nuclear Information System (INIS)

    Doca, C.; Cojocaru, V.

    2005-01-01

    Full text: In 2003, as a national and European premiere, at the Institute for Nuclear Research Pitesti (INR), the Fueling Machine Head no.4 (F/M) for the Nuclear Power Plant Cernavoda - Unit 2 was successfully tested. In 2005, a second Fueling Machine (no.5) was tested for the Nuclear Power Plant Cernavoda - Unit 2. The Institute's main objective is to develop scientific and technological support for the Romanian Nuclear Power Program. Testing the Fueling Machines at INR Pitesti is part of the overall program to assimilate in Romania the CANDU technology. To perform the tests of these machines at INR Pitesti, a special testing rig was built and is available for this goal. Both the testing rig and staff had successfully assessed by the AECL representatives during two missions. There was a delivery contract between GEC Canada and Nuclear Power Plant Cernavoda - Unit 2 to provide the Fueling Machines no. 4 and no. 5 in Romania before testing operation. As a first conclusion, the Institute for Nuclear Research Pitesti has the facilities, the staff and the experience to perform possible co-operations with any other CANDU Reactor owner. This experience will support the next steps concerning F/M commissioning in the NPP Cernavoda - Unit 2 and also give the confidence to the end-users that the Institute's team can provide technical assistance during the operation. Also, the obtained results demonstrate that the overall refurbishment of the F/M control system in Unit 1 and Unit 2 will be possible. The paper presents: - a short description of the F/M head;- a short description of the F/M test rig; - the computer control system; - the F/M testing activities; -results and expectations. (authors)

  8. Review of the Thermal-Chemical Experiments for CANDU Fuel Channel

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Hyoung Tae; Min, Byung Joo; Park, Joo Hwan; Yoon, Churl; Rhee, Bo Wook

    2005-08-15

    In the present study, thermal-chemical experiments for CANDU channel analysis are reviewed. First, 11 experiments are identified from the present references and classified according to the number of heater rods, channel orientation, and degree of FES (Fuel Element Simulator) temperature rise during transient. The main configuration of the test rigs and the position of the measurement systems are identified. The experiments were generally conducted in three stages, a low-power, a high-power and a no-power stage. These test procedures are classified and described in this document. The experimental conditions for steam, coolant, and heat power are identified. The thermal properties of solid materials and fluids in the test apparatus are listed in the tables. From the review of the main test results, the following conclusions are to be obtained. Some of the reviewed experiments were not in the quasy-steady state conditions at a low-power stage and followed by a high-power stage. Zircaloy/steam reaction started when FES temperature were 800 .deg. C and escalated when temperature exceeded 1150 .deg. C. Uncontrolled temperature escalations due to Zircaloy/steam reaction were not observed when the FES temperature reached peak point (just below the melting point) and electric power to the test section shut off (self-sustaining Zircaloy/steam reaction). There were negligible circumferential temperature gradients in the FES bundle and pressure tube for the experiments performed in a vertical channel orientation. There were, however, noticeable circumferential gradients when the pressure tube was horizontal. These gradients were attributed to slumping of the FES bundle (sagging). Sagging of the bundle may have masked any buoyancy induced temperature gradients. Furthermore, the hot FES sagged towards the pressure tube transferring more heat to the pressure tube and increasing the temperature of the pressure tube.

  9. Review of the Thermal-Chemical Experiments for CANDU Fuel Channel

    International Nuclear Information System (INIS)

    Kim, Hyoung Tae; Min, Byung Joo; Park, Joo Hwan; Yoon, Churl; Rhee, Bo Wook

    2005-08-01

    In the present study, thermal-chemical experiments for CANDU channel analysis are reviewed. First, 11 experiments are identified from the present references and classified according to the number of heater rods, channel orientation, and degree of FES (Fuel Element Simulator) temperature rise during transient. The main configuration of the test rigs and the position of the measurement systems are identified. The experiments were generally conducted in three stages, a low-power, a high-power and a no-power stage. These test procedures are classified and described in this document. The experimental conditions for steam, coolant, and heat power are identified. The thermal properties of solid materials and fluids in the test apparatus are listed in the tables. From the review of the main test results, the following conclusions are to be obtained. Some of the reviewed experiments were not in the quasy-steady state conditions at a low-power stage and followed by a high-power stage. Zircaloy/steam reaction started when FES temperature were 800 .deg. C and escalated when temperature exceeded 1150 .deg. C. Uncontrolled temperature escalations due to Zircaloy/steam reaction were not observed when the FES temperature reached peak point (just below the melting point) and electric power to the test section shut off (self-sustaining Zircaloy/steam reaction). There were negligible circumferential temperature gradients in the FES bundle and pressure tube for the experiments performed in a vertical channel orientation. There were, however, noticeable circumferential gradients when the pressure tube was horizontal. These gradients were attributed to slumping of the FES bundle (sagging). Sagging of the bundle may have masked any buoyancy induced temperature gradients. Furthermore, the hot FES sagged towards the pressure tube transferring more heat to the pressure tube and increasing the temperature of the pressure tube

  10. CANDU fuel-cycle vision

    International Nuclear Information System (INIS)

    Boczar, P.G.

    1999-01-01

    The fuel-cycle path chosen by a particular country will depend on a range of local and global factors. The CANDU reactor provides the fuel-cycle flexibility to enable any country to optimize its fuel-cycle strategy to suit its own needs. AECL has developed the CANFLEX fuel bundle as the near-term carrier of advanced fuel cycles. A demonstration irradiation of 24 CANFLEX bundles in the Point Lepreau power station, and a full-scale critical heat flux (CHF) test in water are planned in 1998, before commercial implementation of CANFLEX fuelling. CANFLEX fuel provides a reduction in peak linear element ratings, and a significant enhancement in thermalhydraulic performance. Whereas natural uranium fuel provides many advantages, the use of slightly enriched uranium (SEU) in CANDU reactors offers even lower fuel-cycle costs and other benefits, such as uprating capability through flattening the channel power distribution across the core. Recycled uranium (RU) from reprocessing spent PWR fuel is a subset of SEU that has significant economic promise. AECL views the use of SEU/RU in the CANFLEX bundle as the first logical step from natural uranium. High neutron economy enables the use of low-fissile fuel in CANDU reactors, which opens up a spectrum of unique fuel-cycle opportunities that exploit the synergism between CANDU reactors and LWRs. At one end of this spectrum is the use of materials from conventional reprocessing: CANDU reactors can utilize the RU directly without re-enrichment, the plutonium as conventional Mixed-oxide (MOX) fuel, and the actinide waste mixed with plutonium in an inert-matrix carrier. At the other end of the spectrum is the DUPIC cycle, employing only thermal-mechanical processes to convert spent LWR fuel into CANDU fuel, with no purposeful separation of isotopes from the fuel, and possessing a high degree of proliferation resistance. Between these two extremes are other advanced recycling options that offer particular advantages in exploiting the

  11. CANDU fuel-cycle vision

    International Nuclear Information System (INIS)

    Boczar, P.G

    1998-05-01

    The fuel-cycle path chosen by a particular country will depend on a range of local and global factors. The CANDU reactor provides the fuel-cycle flexibility to enable any country to optimize its fuel-cycle strategy to suit its own needs. AECL has developed the CANFLEX fuel bundle as the near-term carrier of advanced fuel cycles. A demonstration irradiation of 24 CANFLEX bundles in the Point Lepreau power station, and a full-scale critical heat flux (CHF) test in water are planned in 1998, before commercial implementation of CANFLEX fuelling. CANFLEX fuel provides a reduction in peak linear element ratings, and a significant enhancement in thermalhydraulic performance. Whereas natural uranium fuel provides many advantages, the use of slightly enriched uranium (SEU) in CANDU reactors offers even lower fuel-cycle costs and other benefits, such as uprating capability through flattening the channel power distribution across the core. Recycled uranium (RU) from reprocessing spent PWR fuel is a subset of SEU that has significant economic promise. AECL views the use of SEU/RU in the CANFLEX bundle as the first logical step from natural uranium. High neutron economy enables the use of low-fissile fuel in CANDU reactors, which opens up a spectrum of unique fuel-cycle opportunities that exploit the synergism between CANDU reactors and LWRs. At one end of this spectrum is the use of materials from conventional reprocessing: CANDU reactors can utilize the RU directly without reenrichment, the plutonium as conventional mixed-oxide (MOX) fuel, and the actinide waste mixed with plutonium in an inert-matrix carrier. At the other end of the spectrum is the DUPIC cycle, employing only thermal-mechanical processes to convert spent LWR fuel into CANDU fuel, with no purposeful separation of isotopes from the fuel, and possessing a high degree of proliferation resistance. Between these two extremes are other advanced recycling options that offer particular advantages in exploiting the

  12. Two-phase natural circulation experiments in a pressurized water loop with CANDU geometry

    International Nuclear Information System (INIS)

    Ardron, K.H.; Krishnan, V.S.; McGee, G.R.; Anderson, J.W.D.; Hawley, E.H.

    1984-07-01

    To provide information on two-phase natural circulation in a CANDU-type coolant circuit a series of tests has been performed in the RD-12 loop at the Whiteshell Nuclear Research Establishment. RD-12 is a 10-MPa pressurized-water loop containing two active boilers, two pumps, and two, or four, heated horizontal channels arranged in a symmetrical figure-of-eight configuration characteristic of the CANDU reactor primary heat-transport system. In the tests, single-phase natural circulation was established in the loop and void was introduced by controlled draining, with the surge tank (pressurizer) valved out of the system. The paper reviews the experimental results obtained and describes the evolution of natural circulation flow in particular cases as voidage is progressively increased. The stability behaviour is discussed briefly with reference to a simple stability model

  13. Improving CANDU annunciation - Current R and D and future directions

    International Nuclear Information System (INIS)

    Lupton, L.R.; Feher, M.P.; Davey, E.C.; Guo, K.Q.; Bhuiyan, S.H.

    1994-01-01

    Annunciation is used to ensure that control room staff are promptly alerted to important changes in plant conditions that may impact on safety and production goals. We are carrying out research and development to improve CANDU annunciation, in partnership with Canadian CANDU utility and design organizations. The main goal is to solve the ''information overload'' problem that occurs during major plant upsets, while providing operators with annunciation information needed to prevent, mitigate, and accommodate plant disturbances. To data, a set of annunciation concepts has been developed based on operational needs in a complex supervisory control environment. A prototype annunciation system has been developed and demonstrated with Point Lepreau Generating Station operations staff. Preliminary evaluations show that the system has the potential to solve many of the current problems associated with upset management. Further evaluation of this system is planned for 1994/95. This paper summarizes the project, including the current status, lessons learned to data, future directions of the research, and implementation by plants. (author). 9 refs, 3 figs, 1 tab

  14. Technical specifications and performance of CANDU fuel

    International Nuclear Information System (INIS)

    Sejnoha, R.

    1997-01-01

    The relations between Technical Specifications and fuel performance are discussed in terms of design limits and margins. The excellent performance record of CANDU reactor fuel demonstrates that the fuel design defined in the Technical Specifications (and with it other components of the procurement cycle, such as fuel manufacturing), satisfy the requirements. New requirements, changing conditions of fuel application and accumulating experience make periodic updates of the Technical Specifications necessary. Under the CANDU Owners Group (COG) Working Party 9, a Work Package has been conducted to support the review of the Specifications and the documentation of the rationales for their requirements. So far, the review has been completed for 4 Specifications: 1 for Zircaloy tubing, and 3 for uranium dioxide powder. It is planned to complete the review of all 11 currently used specifications by 1999. The paper summarizes the results achieved to mid 1997. (author)

  15. Life extension of CANDU reactor cores

    International Nuclear Information System (INIS)

    Millard, J.; Kerker, J.; Albert, M.

    2011-01-01

    Candu Energy (formerly AECL), in partnership with station operators, has developed a robust methodology for demonstrating the fitness of reactor core structures, and associated reactivity control devices, as an essential element in conducting a station life extension project. The ageing of reactors is affected by ageing mechanisms impacted by operational history and design related factors such as materials, chemistries and stress distributions. The methodology of this life extension work is based on the IAEA TECDOC 1197; which documents practices for ageing management in CANDU reactors. This paper uses the work in Bruce Units 1 and 2, conducted from 2007 through to 2011, to explain the methodology. The work started with analysis of historical operational conditions and identification of the forms of degradation that could have occurred. The assessment and related inspections considered the safety and pressure boundary significance of each item, as well as its failure modes and margins. It then moved through both general and local inspection, focused mainly inside the calandria vessel once the calandria tubes were removed. The inspection found the bulk of the hardware to be in good condition, with a small number of remediation opportunities. In the course of that remediation some foreign material was sampled and removed. The minor remediation was successful and the work was completed through formal documentation of the fitness for extended life. It has been demonstrated through these analyses and visual inspections that the reactor structures and components inspected are free of indications and active degradation mechanisms that would prevent the safe and reliable operation of Bruce A Units 1 and 2 through its next 25 years of life. (author)

  16. An experimental study of a flashing-driven CANDU moderator cooling system

    Energy Technology Data Exchange (ETDEWEB)

    Khartabil, H F; Spinks, N J [Atomic Energy of Canada Ltd., Chalk River, ON (Canada)

    1996-12-31

    The results of an experimental study to investigate the feasibility of using a passive flashing-driven natural circulation loop for CANDU-reactor moderator heat rejection are presented. A scaled loop was constructed and tested at conditions approximating those of a CANDU calandria cooling system. The results showed that stable loop operation was possible at simulated powers approaching normal full power. At lower powers, flow oscillations occurred as the flow in the hot-leg periodically changed from two-phase to single-phase. The results from earlier numerical predictions using the CATHENA thermalhydraulics code showed good qualitative agreement with the experimental results. (author). 6 refs., 11 figs.

  17. CANDU severe accident management guidance update

    International Nuclear Information System (INIS)

    Jones, L.; Popov, N.; Gilbert, L.; Weed, J.

    2014-01-01

    The CANDU Owners Group (COG) developed a set of generic and initial station-specific Severe Accident Management Guidance (SAMG) documents to mitigate the consequences to the public in the event of a severe accident. The generic portion of the COG SAMG was completed in 2006; the overall project including the station-specific phase was completed in April 2007. Over the years, the CANDU industry and utilities have continuously increased the knowledge base for SAMG and have incorporated various engineered features based on the knowledge obtained. As a result of the event that occurred at the Fukushima Daiiachi nuclear power plant (NPP) in Japan, the Canadian Nuclear Safety Commission (CNSC) established the CNSC Fukushima Task Force. The results of the task force were documented in INFO-0828, CNSC Staff Action Plan on the CNSC Fukushima Task Force Recommendations. Among the recommendation documented in INFO-828 were Fukushima Action Items (FAIs) directed towards the CANDU utilities in Canada; a portion of which are related to SAMG documentation updates and directed at enhancing SAM response. A COG joint project was established to support the closure of the CNSC FAIs and to revise the current CANDU documentation accordingly. This paper provides a high level summary of the COG project scope and results. It also demonstrates that the CANDU SAMG programs in Canada provide robust protection and mitigation of severe accidents. (author)

  18. CANDU severe accident management guidance update

    Energy Technology Data Exchange (ETDEWEB)

    Jones, L., E-mail: lisa.m.jones@opg.com [Ontario Power Generation, Pickering, ON (Canada); Popov, N., E-mail: nik.popov@rogers.com [Candu Owners Group, Toronto, ON (Canada); Gilbert, L., E-mail: lovell.gilbert@brucepower.com [Bruce Power, Tiverton, ON (Canada); Weed, J., E-mail: jeff.weed@candu.gov [Candu Owners Group, Toronto, ON (Canada)

    2014-07-01

    The CANDU Owners Group (COG) developed a set of generic and initial station-specific Severe Accident Management Guidance (SAMG) documents to mitigate the consequences to the public in the event of a severe accident. The generic portion of the COG SAMG was completed in 2006; the overall project including the station-specific phase was completed in April 2007. Over the years, the CANDU industry and utilities have continuously increased the knowledge base for SAMG and have incorporated various engineered features based on the knowledge obtained. As a result of the event that occurred at the Fukushima Daiiachi nuclear power plant (NPP) in Japan, the Canadian Nuclear Safety Commission (CNSC) established the CNSC Fukushima Task Force. The results of the task force were documented in INFO-0828, CNSC Staff Action Plan on the CNSC Fukushima Task Force Recommendations. Among the recommendation documented in INFO-828 were Fukushima Action Items (FAIs) directed towards the CANDU utilities in Canada; a portion of which are related to SAMG documentation updates and directed at enhancing SAM response. A COG joint project was established to support the closure of the CNSC FAIs and to revise the current CANDU documentation accordingly. This paper provides a high level summary of the COG project scope and results. It also demonstrates that the CANDU SAMG programs in Canada provide robust protection and mitigation of severe accidents. (author)

  19. Testing a CANDU-fueling machine at the Institute for Nuclear Research Pitesti

    International Nuclear Information System (INIS)

    Cojocaru, Virgil

    2006-01-01

    In 2003, as a national and European premiere, the Fueling Machine Head no. 4 (F/M) for the Nuclear Power Plant Cernavoda Unit 2 (NPP) was successfully tested at the Institute for Nuclear Research Pitesti (INR). In 2005, the second Fueling Machine (no. 5) has tested for the Nuclear Power Plant Cernavoda Unit 2. The Institute's main objective is to develop scientific and technological support for the Romanian Nuclear Power Program. Testing the Fueling Machines at INR Pitesti is part of the overall program to assimilate the CANDU technology in Romania. To perform the tests of these machines at INR Pitesti, a special testing rig has built being available for this goal. Both the testing rig and staff had successfully assessed by the AECL representatives during two missions. There was a delivery contract between GEC Canada and Nuclear Power Plant Cernavoda - Unit 2 to provide the Fueling Machines no. 4 and no. 5 in Romania before testing activity. As a first conclusion, the Institute for Nuclear Research Pitesti has the facilities, the staff and the experience to perform possible co-operations with any CANDU Reactor owner

  20. CANDU channel flow verification

    International Nuclear Information System (INIS)

    Mazalu, N.; Negut, Gh.

    1997-01-01

    The purpose of this evaluation was to obtain accurate information on each channel flow that enables us to assess precisely the level of reactor thermal power and, for reasons of safety, to establish which channel is boiling. In order to assess the channel flow parameters, computer simulations were done with the NUCIRC code and the results were checked by measurements. The complete channel flow measurements were made in the zero power cold condition. In hot conditions there were made flow measurements using the Shut Down System 1 (SDS 1) flow devices from 0.1 % F.P. up to 100 % F.P. The NUCIRC prediction for CANDU channel flows and the measurements by Ultrasonic Flow Meter at zero power cold conditions and SDS 1 flow channel measurements at different reactor power levels showed an acceptable agreement. The 100 % F.P. average errors for channel flow of R, shows that suitable NUCIRC flow assessment can be made. So, it can be done a fair prediction of the reactor power distribution. NUCIRC can predict accurately the onset of boiling and helps to warn at the possible power instabilities at high powers or it can detect the flow blockages. The thermal hydraulic analyst has in NUCIRC a suitable tool to do accurate predictions for the thermal hydraulic parameters for different steady state power levels which subsequently leads to an optimal CANDU reactor operation. (authors)

  1. Canadian CANDU plant data systems for technical surveillance and analysis

    International Nuclear Information System (INIS)

    Deverno, M.; Pothier, H.; Xian, C.; Grosbois, J. De; Bosnich, M.

    1996-01-01

    Plant data systems are emerging as a critical plant support system technology. In particular, plant-wide Historical Data Systems (HDS) are pivotal to the successful implementation of technical surveillance and analysis programs supporting plant operations, maintenance, safety, and licensing activities. In partnership with Canadian CANDU utility and design organizations, AECL has conducted a review of current Canadian CANDU HDS approaches with emphasis on understanding the existing functionality and uses of plant historical data systems, their future needs and benefits. The results is a vision of a plant-wide HDS providing seamless access to both near real-time and historical data, user tool-kits for data visualization and analysis, and data management of the large volume of data acquired during the life of a plant. The successful implementation of the HDS vision will lead to higher capability and capacity factors while minimizing Operations, Maintenance, and Administration (OM and A) costs. (author). 5 refs, 3 figs

  2. Canadian CANDU plant data systems for technical surveillance and analysis

    Energy Technology Data Exchange (ETDEWEB)

    Deverno, M; Pothier, H; Xian, C [Atomic Energy of Canada Ltd., Control Centre Technology Branch, Fredericton, NB (Canada); Grosbois, J De; Bosnich, M [Atomic Energy of Canada Ltd., Control Centre Technology Branch, Chalk River, ON (Canada). Chalk River Labs.

    1997-12-31

    Plant data systems are emerging as a critical plant support system technology. In particular, plant-wide Historical Data Systems (HDS) are pivotal to the successful implementation of technical surveillance and analysis programs supporting plant operations, maintenance, safety, and licensing activities. In partnership with Canadian CANDU utility and design organizations, AECL has conducted a review of current Canadian CANDU HDS approaches with emphasis on understanding the existing functionality and uses of plant historical data systems, their future needs and benefits. The results is a vision of a plant-wide HDS providing seamless access to both near real-time and historical data, user tool-kits for data visualization and analysis, and data management of the large volume of data acquired during the life of a plant. The successful implementation of the HDS vision will lead to higher capability and capacity factors while minimizing Operations, Maintenance, and Administration (OM and A) costs. (author). 5 refs, 3 figs.

  3. A probabilistic method for leak-before-break analysis of CANDU reactor pressure tubes

    International Nuclear Information System (INIS)

    Puls, M.P.; Wilkins, B.J.S.; Rigby, G.L.

    1997-01-01

    A probabilistic code for the prediction of the cumulative probability of pressure tube ruptures in CANDU type reactors is described. Ruptures are assumed to result from the axial growth by delayed hydride cracking. The BLOOM code models the major phenomena that affect crack length and critical crack length during the reactor sequence of events following the first indications of leakage. BLOOM can be used to develop unit-specific estimates of the actual probability of pressure rupture in operating CANDU reactors and supplement the existing leak before break analysis

  4. A probabilistic method for leak-before-break analysis of CANDU reactor pressure tubes

    Energy Technology Data Exchange (ETDEWEB)

    Puls, M.P.; Wilkins, B.J.S.; Rigby, G.L. [Whiteshell Labs., Pinawa (Canada)] [and others

    1997-04-01

    A probabilistic code for the prediction of the cumulative probability of pressure tube ruptures in CANDU type reactors is described. Ruptures are assumed to result from the axial growth by delayed hydride cracking. The BLOOM code models the major phenomena that affect crack length and critical crack length during the reactor sequence of events following the first indications of leakage. BLOOM can be used to develop unit-specific estimates of the actual probability of pressure rupture in operating CANDU reactors and supplement the existing leak before break analysis.

  5. Analysis of a homogenous and heterogeneous stylized half core of a CANDU reactor

    Energy Technology Data Exchange (ETDEWEB)

    EL-Khawlani, Afrah [Physics Department, Sana' a (Yemen); Aziz, Moustafa [Nuclear and radiological regulatory authority, Cairo (Egypt); Ismail, Mahmud Yehia; Ellithi, Ali Yehia [Cairo Univ. (Egypt). Faculty of Science

    2015-03-15

    The MCNPX (Monte Carlo N-Particle Transport Code System) code has been used for modeling and simulation of a half core of CANDU (CANada Deuterium-Uranium) reactor, both homogenous and heterogeneous model for the reactor core are designed. The fuel is burnt in normal operation conditions of CANDU reactors. Natural uranium fuel is used in the model. The multiplication factor for homogeneous and heterogeneous reactor core is calculated and compared during fuel burnup. The concentration of both uranium and plutonium isotopes are analysed in the model. The flux and power distributions through channels are calculated.

  6. The structural aging assessment program: ranking methodology for CANDU nuclear generating station concrete components

    International Nuclear Information System (INIS)

    Philipose, K.E.; Muhkerjee, P.K.; McColm, E.J.

    1997-01-01

    Most of the major structural components in CANDU nuclear generating stations are constructed of reinforced concrete. Although passive in nature, these structures perform many critical safety functions in the operation of each facility. Aging can affect the structural capacity and integrity of structures. The reduction in capacity due to aging is not addressed in design codes. Thus a program is warranted to monitor the aging of safety-related CANDU plant structures and to prioritize those that require maintenance and repairs. Prioritization of monitoring efforts is best accomplished by focusing on those structures judged to be the most critical to plant performance and safety. The safety significance of each sub-element and its degradation with time can be evaluated using a numerical rating system. This will simplify the utility's efforts, thereby saving maintenance costs while providing a higher degree of assurance that performance is maintained. This paper describes the development of a rating system (ranking procedure) as part of the Plant Life Management of CANDU generating station concrete structures and illustrates its application to an operating plant. (author)

  7. Value added services to CANDU plants

    International Nuclear Information System (INIS)

    Kakaria, B.K.

    2003-01-01

    Over the last decade or so, nuclear power plants, just like other types of electricity generating plants, have been facing a number of challenges. Depending on the operating environment of the utility, these challenges are forcing plant owners to examine all facets of the operating costs. Privatization, deregulation and economics of alternative electricity generation methods are exerting enormous pressure on nuclear power plants to streamline costs and improve their operational performance. CANDU reactors are no exception to these forces and face similar pressures. In particular, operating plants that are contemplating plant life extensions are being required to clearly demonstrate the economics of continued operation over other forms of power generation available to the utility. Improvement of capacity factors has the effect of increasing the revenues from the plant and as these revenues increase, the fixed portion of the plant costs including OM and A costs become a smaller percentage of the total revenues. Similar results can be achieved by aiming to reduce the plant OM and A costs. In reality, most well-planned intervention schemes directed at reducing OM and A costs tend to also increase the plant availability. Following plant turnover after commissioning, AECL has been supporting the CANDU owners and utilities with an assortment of products and services dealing with plant operations and outage management issues. AECL has taken the lead in arranging specialized resources, products and services by teaming with other complementary organizations to provide a complete suite of services. Recent examples of such support to operating CANDU plants will be described in the paper. AECL is responding to this changing business environment in two important ways. First, AECL is changing from simply providing a service to its clients towards providing value, something much more important. To this end, AECL is looking to other organizations to form alliances, partnerships and

  8. Considerations in selecting tubing materials for CANDU steam generators

    International Nuclear Information System (INIS)

    Hemmings, R.L.

    1978-01-01

    Corrosion resistance is the major consideration in selecting tubing material for CANDU steam generators. Corrosion, and additional considerations, lead to the following steam generator tubing material recommendations: for CANDU-BPHWR's (boiling pressurized heavy water reactors) low-cobalt Incoloy-800; for CANDU-PHWR's (pressurized, non-boiling, heavy water reactors), low-cobalt Monel-400

  9. Physics characteristics of CANDU cores with advanced fuel cycles

    International Nuclear Information System (INIS)

    Garvey, P.M.

    1985-01-01

    The current generation of CANDU reactors, of which some 20 GWE are either in operations or under construction worldwide, have been designed specifically for the natural uranium fuel cycle. The CANDU concept, due to its D 2 O coolant and moderator, on-power refuelling and low absorption structural materials, makes the most effective utilization of mined uranium of all currently commercialized reactors. An economic fuel cycle cost is also achieved through the use of natural uranium and a simple fuel bundle design. Total unit energy costs are achieved that allow this reactor concept to effectively compete with other reactor types and other forms of energy production. There are, however, other fuel cycles that could be introduced into this reactor type. These include the slightly enriched uranium fuel cycle, fuel cycles in which plutonium is recycled with uranium, and the thorium cycle in which U-233 is recycled. There is also a special range of fuel cycles that could utilize the spent fuel from LWR's. Two specific variants are a fuel cycle that only utilizes the spent uranium, and a fuel cycle in which both the uranium and plutonium are recycled into a CANDU. For the main part these fuel cycles are characterized by a higher initial enrichment, and hence discharge burnup, than the natural uranium cycle. For these fuel cycles the main design features of both the reactor and fuel bundle would be retained. Recently a detailed study of the use in a CANDU of mixed plutonium and uranium oxide fuel from an LWR has been undertaken by AECL. This study illustrates many of the generic technical issues associated with the use of Advanced Fuel Cycles. This paper will report the main findings of this evaluation, including the power distribution in the reactor and fuel bundle, the choice of fuel management scheme, and the impact on the control and safety characteristics of the reactor. These studies have not identified any aspects that significantly impact upon the introduction of

  10. Thermal analysis of CANDU6 moderator system for loss of cooling

    International Nuclear Information System (INIS)

    Xu Zhen

    2012-01-01

    The coolant system and moderator system of CANDU6 are independent. The prompt neutrons are moderated as thermal neutrons by the moderator and the continuous nuclear fission in the reactor is maintained. At the same time the moderator system supplies the heat sink for the heat produced by the neutrons moderation. During the in-service maintenance of plant, the standby RCW which will only cool down reactor coolant system operates instead of RCW and can not supply heat sink for moderator system heat exchanger. As the result, the moderator system will lose heat sink during the operation of standby RCW. To estimate the moderator temperature, the thermal analysis of moderator system for loss of cooling was compared with the experiment data and the system failure caused by the temperature raising was evaluated in this paper. (author)

  11. Nuclear fuel element design and thermal-hydraulic analysis of Wolsung-1, 600 MWe CANDU-PHWR (Part II)

    International Nuclear Information System (INIS)

    Suk, H.C; Lee, J.C.; Suh, K.S.; Yuk, K.E.; Whang, W.; Park, J.S.; Eim, J.S.; Bang, K.H.; Eim, M.S.; Rim, C.S.

    1982-01-01

    The main objective of the present thermal hydraulic analysis is to determine the thermal hydraulic characteristics of Wolsung-1 600 MWe CANDU-PHW reactor under normal operation. This is to verify and expedite the development of the nuclear fuel design and fabrication as well as the management. The computer program package developed for the stated objective are DOD81, CANREPP, PLOC81 and COBRA-CANDU. (Author)

  12. Recent advances in self-powered flux detector development for CANDU reactors

    International Nuclear Information System (INIS)

    Allan, C.J.; Drewell, N.H.; Hall, D.S.

    1983-01-01

    The characteristics of self-powered flux detectors used in CANDU reactors are reviewed. Detectors with emitters of vanadium, platinum, platinum-clad Inconel and Inconel are used. Data on dynamic response, relative neutron and gamma-ray sensitivities, and burnout, obtained both from experiments and from the Monte Carlo code ICARES, are presented. Since the response of a detector depends on the relative magnitudes of the various current-producing mechanisms, the operating principles of self-powered detectors are briefly reviewed. Current research programmes are discussed. These include modifying the design of the platinum-clad Inconel detector in order to match its dynamic response to that of the fuel power and developing a prompt-responding flux-mapping detector. (author)

  13. Evaluation on operation of liquid relief valves for steam line break accidents by RELAP5/CANDU+ code

    International Nuclear Information System (INIS)

    Yang, C. Y.; Bang, Y. S.; Kim, H. J.

    2001-01-01

    A development of RELAP5/CANDU+ code for regulatory audits of accident analysis of CANDU nuclear power plants is on progress. This paper is undertaken in a procedure of a verification and validation for RELAP5/CANDU+ code by analyzing main steam line break accidents of WS 2/3/4. Following the ECC injection in sequence of the steam line breaks, the mismatch in heat transfer between the primary and the secondary systems makes pressure of the primary system instantly peaked to the open setpoint of liquid relief valves. The event sequence follows the result of WS 2/3/4 FSAR, but there is a difference in pressure transient after ECC injection. Sensitivity analysis for main factors dependent on the peak pressure such as control logics of liquid relief valves. ECC flow path and feedwater flow is performed. Because the pressure increase is continued for a long time and its peaking is high, open and close of the liquid relief valves are repeated several times, which is obviously different from those of WS 2/3/4 FSAR. As a result, it is evaluated that conservative modeling for the above variables is required in the analysis

  14. MATLAB/SIMULINK platform for simulation of CANDU reactor control system

    International Nuclear Information System (INIS)

    Javidnia, H.; Jiang, J.

    2007-01-01

    In this paper a simulation platform for CANDU reactors' control system is presented. The platform is built on MATLAB/SIMULINK interactive graphical interface. Since MATLAB/SIMULINK are powerful tools to describe systems mathematically, all the subsystems in a CANDU reactor are represented in MATLAB's language and are implemented in SIMULINK graphical representation. The focus of the paper is on the flux control loop of CANDU reactors. However, the ideas can be extended to include other parts in CANDU power plants and the same technique can be applied to other types of nuclear reactors and their control systems. The CANDU reactor model and xenon feedback model are also discussed in this paper. (author)

  15. Fuel cycles - a key to future CANDU success

    International Nuclear Information System (INIS)

    Kuran, S.; Hopwood, J.; Hastings, I.J.

    2011-01-01

    Globally, fuel cycles are being evaluated as ways of extending nuclear fuel resources, addressing security of supply and reducing back-end spent-fuel management. Current-technology thermal reactors and future fast reactors are the preferred platform for such fuel cycle applications and as an established thermal reactor with unique fuel-cycle capability, CANDU will play a key role in fulfilling such a vision. The next step in the evolution of CANDU fuel cycles will be the introduction of Recovered Uranium (RU), derived from conventional reprocessing. A low-risk RU option applicable in the short term comprises a combination of RU and Depleted Uranium (DU), both former waste streams, giving a Natural Uranium Equivalent (NUE) fuel. This option has been demonstrated in China, and all test bundles have been removed from the Qinshan 1 reactor. Additionally, work is being done on an NUE full core, a Thorium demonstration irradiation and an Advanced Fuel CANDU Reactor(AFCR). AECL is developing other fuel options for CANDU, including actinide waste burning. AECL has developed the Enhanced CANDU 6 (EC6) reactor, upgraded from its best-performing CANDU 6 design. High neutron economy, on-power refueling and a simple fuel bundle provide the EC6 with the flexibility to accommodate a range of advanced fuels, in addition to its standard natural uranium. (author)

  16. Technology transfer in CANDU marketing

    International Nuclear Information System (INIS)

    Pon, G.A.

    1982-06-01

    The author discusses how the CANDU system lends itself to technology transfer, the scope of CANDU technology transfer, and the benefits and problems associated with technology transfer. The establishment of joint ventures between supplier and client nations offers benefits to both parties. Canada can offer varying technology transfer packages, each tailored to a client nation's needs and capabilities. Such a package could include all the hardware and software necessary to develop a self-sufficient nuclear infrastructure in the client nation

  17. Future fuel cycle development for CANDU reactors

    International Nuclear Information System (INIS)

    Hatcher, S.R.; McDonnell, F.N.; Griffiths, J.; Boczar, P.G.

    1987-01-01

    The CANDU reactor has proven to be safe and economical and has demonstrated outstanding performance with natural uranium fuel. The use of on-power fuelling, coupled with excellent neutron economy, leads to a very flexible reactor system with can utilize a wide variety of fuels. The spectrum of fuel cycles ranges from natural uranium, through slightly enriched uranium, to plutonium and ultimately thorium fuels which offer many of the advantages of the fast breeder reactor system. CANDU can also burn the recycled uranium and/or the plutonium from fuel discharged from light water reactors. This synergistic relationship could obviate the need to re-enrich the reprocessed uranium and allow a simpler reprocessing scheme. Fule management strategies that will permit future fuel cycles to be used in existing CANDU reactors have been identified. Evolutionary design changes will lead to an even greater flexibility, which will guarantee the continued success of the CANDU system. (author)

  18. Qinshan CANDU project open top construction method

    International Nuclear Information System (INIS)

    Petrunik, K.J.; Wittann, K.; Khan, A.; Ricciuti, R.; Ivanov, A.; Chen, S.

    2003-01-01

    The significant schedule reductions achieved on the Qinshan CANDU Project were due in large part to the incorporation of advanced construction technologies in project design and delivery. For the Qinshan Project, a number of key advantages were realized through the use of the 'Open Top' construction method. This paper discusses the Qinshan Phase III CANDU Project Open Top implementation method. The Open Top method allowed major equipment to be installed simply, via the use of a Very Heavy Lift (VHL) crane and permitted the use of large-scale modularization. The advantages of Open Top construction, such as simplified access, more flexible project scheduling, improved construction safety and quality, and reduced labours are presented. The large-scale modularization of the Reactor Building Dousing System and the Open Top installation method and advantages relative to traditional CANDU 6 construction practices are also presented. Finally, major improvements for future CANDU plant construction using the Open Top method are discussed. (author)

  19. Development of Zr-2.5Nb pressure tubes for Advanced CANDU Reactor

    International Nuclear Information System (INIS)

    Bickel, G.A.; Griffiths, M.; Douchant, A.; Douglas, S.; Woo, O.T.; Buyers, A.

    2010-01-01

    In an Advanced CANDU Reactor (ACR), pressure tubes of cold-worked Zr-2.5Nb materials will be used in the reactor core to contain the fuel bundles and the light water coolant. They will be subjected to higher temperature, pressure and flux than that in a CANDU reactor. In order to ensure that these tubes will perform acceptably over their 30-year design life in such an environment, a manufacturing process has been developed to produce 6.5 mm thick ACR pressure tubes with optimized chemical composition, improved mechanical properties and in-reactor behaviour. The test and examination results show that, when compared with current in-service pressure tubes, the mechanical properties of ACR pressure tubes are significantly improved. Based on previous experience with CANDU reactor pressure tubes an assessment of the grain structure and texture indicates that the in-reactor creep deformation will be improved also. Analysis of the distribution of texture parameters from a trial batch of 26 tubes shows that the variability is reduced relative to tubes fabricated in the past. This reduction in variability together with a shift to a coarser grain structure will result in a reduction in diametral creep design limits and thus a longer economic life for the fuel channels of the advanced CANDU reactor. (author)

  20. Methodology of structural integrity assesment of CANDU-6 NPP fuel channels

    International Nuclear Information System (INIS)

    Radu, Vasile

    2004-01-01

    The paper describes the methodology of assessing the structural integrity in the CANDU-6 fuel channels making use of alternative methods of evaluation. An evaluation of the structural integrity of a CANDU-6 pressure tube made of Zr-2,5%Nb presenting both sharp and blunted defects is done. These analyses are made in compliance with the Canadian guide 'Pressure Tubes Fitness-for-service', and other two Recognizing procedures internationally adopted: the British procedure R6/Rev.4 and the American procedure API 579. Previously, the data base containing the data on materials property as well as the heat and dynamical loads in normal operation in CANDU-6 pressure tubes was established. Obtaining complete diagrams for structural integrity of pressure tubes with sharp and blunted defects in conditions of normal operation and long-term irradiation is the next step of the methodology to be developed. Modelling sharp and blunted defects on the inner side of pressure tubes, which can occur in normal reactor operating conditions is achieved by means of capabilities of pre-processing of two finite element analysis codes namely FEA-Crack and FEA-Flaw. The second part of the work deals with the analyses by finite element method of the fracture mechanics by means of the FEA-Crack code and with the evaluation of sharp and blunted defects by FAD diagrams in compliance with the British procedure R6/Rev.4. For typical models of blunted defects and thermo-mechanical loads specific to normal operation finite element analyses by FEA-Flaw codes were performed. Then FAD-iDHC diagrams were constructed to evaluate the initiation of the slow cracking under hydrogen/deuterium absorption, the known phenomenon of delayed hydride cracking (DHC)

  1. Absorber materials in CANDU PHWR's

    International Nuclear Information System (INIS)

    Price, E.G.; Boss, C.R.; Novak, W.Z.; Fong, R.W.L.

    1995-03-01

    In a CANDU reactor the fuel channels are arranged on a square lattice in a calandria filled with heavy water moderator. This arrangement allows five types of tubular neutron absorber devices to be located in a relatively benign environment of low pressure, low temperature heavy water between neighbouring rows of columns of fuel channels. This paper will describe the roles of the devices and outline the design requirements of the absorber component from a reactor physics viewpoint. Nuclear heating and activation problems associated with the different absorbers will be briefly discussed. The design and manufacture of the devices will be also discussed. The control rod absorbers and shut off materials are cadmium and stainless steel. In the tubular arrangement, the cadmium is sandwiched between stainless steel tubes. This type of device has functioned well, but there is now concern over the availability and expense of cadmium which is used in two types of CANDU control devices. There are also concerns about the toxicity of cadmium during the fabrication of the absorbers. These concerns are prompting AECL to study alternatives. To minimize design changes, pure boron-10 alloyed in stainless steel is a favoured option. Work is underway to confirm the suitability of the boron-loaded steel and identify other encapsulated absorber materials for practical application. Because the reactivity devices or their guide tubes span the calandria vessel, the long slender components must be sufficiently rigid to resist operational vibration and also be seismically stable. Some of these components are made of Zircaloy to minimize neutron absorption. Slow irradiation growth and creep can reduce the spring tension, and periodic adjustments to the springs are required. Experience with the control absorber devices has generally been good. In one instance liquid zone controllers had a problem of vibration induced fretting but a designed back-fit resolved the problem. (author). 3 refs., 1

  2. Assessment of reactivity devices for CANDU-6 with DUPIC fuel

    International Nuclear Information System (INIS)

    Jeong, Chang Joon; Choi, Hang Bok

    1998-01-01

    Reactivity device characteristics for a CANDU-6 reactor loaded with DUPIC fuel have been assessed. A transport code WIMS-AECL and a three-dimensional diffusion code RFSP were used for the lattice parameter generation and the core calculation, respectively. Three major reactivity devices have been assessed for their inherent functions. For the zone controller system, damping capability for spatial oscillation was investigated. The restart capability of the adjuster system was investigated. The shim operation and power stepback calculation were also performed to confirm the compatibility of the current adjuster rod system. The mechanical control absorber was assessed for the capability to compensate the temperature reactivity feedback following a power reduction. This study has shown that the current reactivity device systems retain their functions when used in a DUPIC fuel CANDU reactor

  3. The CANDU alarm analysis tool (CAAT)

    Energy Technology Data Exchange (ETDEWEB)

    Davey, E C; Feher, M P; Lupton, L R [Control Centre Technology Branch, ON (Canada)

    1997-09-01

    AECL undertook the development of a software tool to assist alarm system designers and maintainers based on feedback from several utilities and design groups. The software application is called the CANDU Alarm Analysis Tool (CAAT) and is being developed to: Reduce by one half the effort required to initially implement and commission alarm system improvements; improve the operational relevance, consistency and accuracy of station alarm information; record the basis for alarm-related decisions; provide printed reports of the current alarm configuration; and, make day-to-day maintenance of the alarm database less tedious and more cost-effective. The CAAT assists users in accessing, sorting and recording relevant information, design rules, decisions, and provides reports in support of alarm system maintenance, analysis of design changes, or regulatory inquiry. The paper discusses the need for such a tool, outlines the application objectives and principles used to guide tool development, describes the how specific tool features support user design and maintenance tasks, and relates the lessons learned from early application experience. (author). 4 refs, 2 figs.

  4. The CANDU alarm analysis tool (CAAT)

    International Nuclear Information System (INIS)

    Davey, E.C.; Feher, M.P.; Lupton, L.R.

    1997-01-01

    AECL undertook the development of a software tool to assist alarm system designers and maintainers based on feedback from several utilities and design groups. The software application is called the CANDU Alarm Analysis Tool (CAAT) and is being developed to: Reduce by one half the effort required to initially implement and commission alarm system improvements; improve the operational relevance, consistency and accuracy of station alarm information; record the basis for alarm-related decisions; provide printed reports of the current alarm configuration; and, make day-to-day maintenance of the alarm database less tedious and more cost-effective. The CAAT assists users in accessing, sorting and recording relevant information, design rules, decisions, and provides reports in support of alarm system maintenance, analysis of design changes, or regulatory inquiry. The paper discusses the need for such a tool, outlines the application objectives and principles used to guide tool development, describes the how specific tool features support user design and maintenance tasks, and relates the lessons learned from early application experience. (author). 4 refs, 2 figs

  5. Passive heat transport in advanced CANDU containment

    International Nuclear Information System (INIS)

    Krause, M.; Mathew, P.M.

    1994-01-01

    A passive CANDU containment design has been proposed to provide the necessary heat removal following a postulated accident to maintain containment integrity. To study its feasibility and to optimize the design, multi-dimensional containment modelling may be required. This paper presents a comparison of two CFD codes, GOTHIC and PHOENICS, for multi-dimensional containment analysis and gives pressure transient predictions from a lumped-parameter and a three-dimensional GOTHIC model for a modified CANDU-3 containment. GOTHIC proved suitable for multidimensional post-accident containment analysis, as shown by the good agreement with pressure transient predictions from PHOENICS. GOTHIC is, therefore, recommended for passive CANDU containment modelling. (author)

  6. Build your own Candu reactor

    International Nuclear Information System (INIS)

    Carruthers, J.

    1979-01-01

    The author discusses the marketing of Candu reactors, particularly the export trade. Future sales will probably be of the nuclear side of a station only, thus striking a compromise between licensing and 'turnkey' sales. It is suggested that AECL might have made more money in the past had it not given the right to manufacture Candu fuel away to Canadian industry. Future sales to certain potential customers may be limited by the requirement of strict safeguards, which will almost certainly never be relaxed. (N.D.H.)

  7. CANDU in Romania

    International Nuclear Information System (INIS)

    Keillor, M.

    1990-01-01

    The author, a former journalist, and now manager of media relations at AECL CANDU, visited Romania to get a first-hand account of conditions at the Cernavoda site. He refutes allegations of slave labour, or inhuman conditions

  8. Development of thermal-hydraulic models for the safety evaluation of CANDU reactors

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Jae Young; Hwang, Gi Suk; Jung, Yun Sik [Handong Univ., Pohang (Korea, Republic of); No, Hee Cheon; Moon, Young Min [Korea Advanced Institute of Science and Technology, Taejon (Korea, Republic of)

    2003-03-15

    The objective of the present research is to evaluate the safety analysis for CANDU and to improve the Horizontal Stratification Entrainment Model (HSEM) of RELAP5/MOD3.3. This report includes two items : the one is the development of experimental facility for the safety evaluation of CANDU, the other is the results of comparison with the existing correlations and data. The literature reviews are performed and the database for previous off-take experiments are built. By a survey of state-of-the-articles, the deficiencies of previous works and limitations of existing models are examined. The hydraulic behavior branching through the feeder pipes from the header pipe is analyzed and the test facility of off-take experiment is designed and manufactured as the prototype CANDU6, by a proper scaling methodologies. The test facility contains various branch pipes not only for three directions (top, side and bottom), but for arbitrary directions. The experiments about the onset of entrainment and branch quality only for three directions (top, side and bottom) are carried out by using air-water as working fluids. On the whole, the existing correlations predict the present experimental results well branch quality, entrainment, which validates the availability of experimental facility and methodology. Especially, for the branch quality with top and bottom branches, the different results are shown because of the unstable flow regimes in the horizontal pipe and the different branch diameters. The deficiencies of previous works and limitations of existing models are considered. The off-take experiment for arbitrary branch angles continues as the next year research.

  9. GENOVA: a generalized perturbation theory program for various applications to CANDU core physics analysis (I)-theory and application

    International Nuclear Information System (INIS)

    Kim, Do Heon; Choi, Hang Bok

    2001-01-01

    A generalized perturbation theory (GPT) program, GENOVA, has been developed for the purpose of various applications to Canadian deuterium uranium (CANDU) reactor physics analyses. GENOVA was written under the framework of CANDU physics design and analysis code, RFSP. A sensitivity method based on the GPT was implemented in GENOVA to estimate various sensitivity coefficients related to the movement of zone controller units (ZCUs) existing in the CANDU reactor. The numerical algorithm for the sensitivity method was verified by a simple 2 x 2 node problem. The capability of predicting ZCU levels upon a refueling perturbation was validated for a CANDU-6 reactor problem. The applicability of GENOVA to the CANDU-6 core physics analysis has been demonstrated with the optimum refueling simulation and the uncertainty analysis problems. For the optimum refueling simulation, an optimum channel selection strategy has been proposed, using the ZCU level predicted by GENOVA. The refueling simulation of a CANDU-6 natural uranium core has shown that the ZCU levels are successfully controlled within the operating range while the channel and bundle powers are satisfying the license limits. An uncertainty analysis has been performed for the fuel composition heterogeneity of a CANDU DUPIC core, using the sensitivity coefficients generated by GENOVA. The results have shown that the uncertainty of the core performance parameter can be reduced appreciably when the contents of the major fissile isotopes are tightly controlled. GENOVA code has been successfully explored to supplement the weak points of the current design and analysis code, such as the incapacity of performing an optimum refueling simulation and uncertainty analysis. The sample calculations have shown that GENOVA has strong potential to be used for CANDU core analysis combined with the current design and analysis code, RFSP, especially for the development of advanced CANDU fuels

  10. Natural circulation in an integral CANDU test facility

    International Nuclear Information System (INIS)

    Ingham, P.J.; Sanderson, T.V.; Luxat, J.C.; Melnyk, A.J.

    2000-01-01

    Over 70 single- and two-phase natural circulation experiments have been completed in the RD-14M facility, an integral CANDU thermalhydraulic test loop. This paper describes the RD-14M facility and provides an overview of the impact of key parameters on the results of natural circulation experiments. Particular emphasis will be on phenomena which led to heat up at high system inventories in a small subset of experiments. Clarification of misunderstandings in a recently published comparison of the effectiveness of natural circulation flows in RD-14M to integral facilities simulating other reactor geometries will also be provided. (author)

  11. MATLAB/SIMULINK model of CANDU reactor for control studies

    International Nuclear Information System (INIS)

    Javidnia, H.; Jiang, J.

    2006-01-01

    In this paper a MATLAB/SIMULINK model is developed for a CANDU type reactor. The data for the reactor are taken from an Indian PHWR, which is very similar to CANDU in its design. Among the different feedback mechanisms in the core of the reactor, only xenon has been considered which plays an important role in spatial oscillations. The model is verified under closed loop scenarios with simple PI controller. The results of the simulation show that this model can be used for controller design and simulation of the reactor systems. Adding models of the other components of a CANDU reactor would ultimately result in a complete model of CANDU plant in MATLAB/SIMULINK. (author)

  12. Validation of physics and thermalhydraulic computer codes for advanced Candu reactor applications

    International Nuclear Information System (INIS)

    Wren, D.J.; Popov, N.; Snell, V.G.

    2004-01-01

    Atomic Energy of Canada Ltd. (AECL) is developing an Advanced Candu Reactor (ACR) that is an evolutionary advancement of the currently operating Candu 6 reactors. The ACR is being designed to produce electrical power for a capital cost and at a unit-energy cost significantly less than that of the current reactor designs. The ACR retains the modular Candu concept of horizontal fuel channels surrounded by a heavy water moderator. However, ACR uses slightly enriched uranium fuel compared to the natural uranium used in Candu 6. This achieves the twin goals of improved economics (via large reductions in the heavy water moderator volume and replacement of the heavy water coolant with light water coolant) and improved safety. AECL has developed and implemented a software quality assurance program to ensure that its analytical, scientific and design computer codes meet the required standards for software used in safety analyses. Since the basic design of the ACR is equivalent to that of the Candu 6, most of the key phenomena associated with the safety analyses of ACR are common, and the Candu industry standard tool-set of safety analysis codes can be applied to the analysis of the ACR. A systematic assessment of computer code applicability addressing the unique features of the ACR design was performed covering the important aspects of the computer code structure, models, constitutive correlations, and validation database. Arising from this assessment, limited additional requirements for code modifications and extensions to the validation databases have been identified. This paper provides an outline of the AECL software quality assurance program process for the validation of computer codes used to perform physics and thermal-hydraulics safety analyses of the ACR. It describes the additional validation work that has been identified for these codes and the planned, and ongoing, experimental programs to extend the code validation as required to address specific ACR design

  13. GENOVA: a generalized perturbation theory program for various applications to CANDU core physics analysis (II) - a user's manual

    International Nuclear Information System (INIS)

    Kim, Do Heon; Choi, Hang Bok

    2001-03-01

    A user's guide for GENOVA, a GENeralized perturbation theory (GPT)-based Optimization and uncertainty analysis program for Canada deuterium uranium (CANDU) physics VAriables, was prepared. The program was developed under the framework of CANDU physics design and analysis code RFSP. The generalized perturbation method was implemented in GENOVA to estimate the zone controller unit (ZCU) level upon refueling operation and calculate various sensitivity coefficients for fuel management study and uncertainty analyses, respectively. This documentation contains descriptions and directions of four major modules of GENOVA such as ADJOINT, GADJINT, PERTURB, and PERTXS so that it can be used as a practical guide for GENOVA users. This documentation includes sample inputs for the ZCU level estimation and sensitivity coefficient calculation, which are the main application of GENOVA. The GENOVA can be used as a supplementary tool of the current CANDU physics design code for advanced CANDU core analysis and fuel development

  14. The future role of thorium in assuring CANDU fuel supplies

    International Nuclear Information System (INIS)

    Slater, J.B.

    1985-01-01

    Atomic Energy of Canada Limited (AECL), in partnership with Canadian industry and power utilities, has developed the CANDU reactor as a safe, reliable and economic means of transforming nuclear fuel into useable power. The use of thorium/uranium-233 recycle gives the possibility of a many-fold increase in energy yield over that which can be obtained from the use of uranium in once-through cycles. The neutronic properties of uranium-233 combine with the inherent neutron economy of the CANDU reactor to offer the possibility of near-breeder cycles in which there is no net consumption of fissile material under equilibrium fuelling conditions. Use of thorium cycles in CANDU will limit the impact of higher uranium prices. When combined with the potential for significant reductions in CANDU capital costs, then the long-term prospect is for generating costs near to current levels. Development of thorium cycles in CANDU will safeguard against possible uranium shortages in the next century, and will maintain and continue the commercial viability of CANDU as a long-term energy technology. (author)

  15. R and D activities on CANDU-type fuel in Indonesia

    International Nuclear Information System (INIS)

    Suripto, A.; Badruzzaman, M.; Latief, A.

    1997-01-01

    The status of R and D activities in Indonesia with respect of CANDU-type fuel development is presented. The activities have been started since the first feasibility study to introduce nuclear power plants was carried out in 1970s. The early research comprised the in-situ pilot production of yellow-cake in Kalimantan (Borneo) experimental mining site, uranium purification and pellet preparation. This program continued to gain a full support from the Government which culminated in the realisation of the construction by BATAN of a large fuel development laboratory in Serpong, starting from 1984 in co-operation with NIRA Ansaldo of Italy. The laboratory, which is called the Power Reactor Experimental Fuel Element Installation (EFEI) was originally designed as an experimental facility to integrate the acquired domestic R and D results gained so far on the CANDU-type fuel technology and the additional know-how received from NIRA Ansaldo which at that time was engaged, in developing a CANDU-type fuel, called the CIRENE fuel design. In the present days the facility houses the power reactor fuel development activities carried out to build up the national capability on power reactor fuel fabrication technology in anticipation to embark upon the nuclear energy era in the near future. (author)

  16. Approach for seismic risk analysis for CANDU plants in Korea

    Energy Technology Data Exchange (ETDEWEB)

    Lee, B-S; Kim, T; Kang, S-K [Korea Power Engineering Co., Seoul (Korea, Republic of); Hong, S-Y; Roh, S-R [Korea Electric Power Corp., Taejon (Korea, Republic of). Research Centre

    1996-12-31

    A seismic risk analysis for CANDU type plants has never been performed. The study presented here suggested that the approach generally applied to LWR type plants could lead to unacceptable result, if directly applied to CANDU plants. This paper presents a modified approach for the seismic risk analysis of CANDU plants. (author). 5 refs., 2 tabs., 2 figs.

  17. TEPC performance in the CANDU workplace

    International Nuclear Information System (INIS)

    Waker, A.J.; Szornel, K.; Nunes, J.

    1997-01-01

    Tissue-equivalent proportional counters (TEPCs) have a number of features that make them an attractive option for neutron monitoring around power reactors. These features are principally the ability of the TEPC to operate in a mixed field environment, the direct determination of the dose equivalent from first principles and a reasonably well-understood response to the wide range of neutron energy encountered. A spherical TEPC from Far West Technology (5'' in diameter) and a commercial, TEPC-based, neutron monitor (REM 500) have been used to map the neutron fields at different locations in a CANDU 6 (Canadian Deuterium Uranium) power reactor operated by New Brunswick Power. Neutron ambient dose equivalent rates ranged between 8 μSv.h -1 and 500 μSv.h -1 as measured with a multisphere spectrometer and photon dose equivalent rates from 40 μSv.h -1 to 1.2 mSv.H -1 as determined with a TEPC. It is shown that, for the CANDU workplace, the energy response of TEPCs is still not known accurately enough to enable field correction factors to be derived from neutron fluence measurements or to avoid the the need for more appropriate calibration procedures based on simulated 'workplace' neutron fields. The sensitivity of TEPCs is sufficient for workplace monitoring, but needs consideration when counters of 2'' diameter or smaller are proposed for use. For mixed-field work, the use of a TEPC for photon dosimetry as opposed to photon discrimination requires attention to count rates and instrument dead time. (author)

  18. Qinshan CANDU NPP outage performance improvement through benchmarking

    International Nuclear Information System (INIS)

    Jiang Fuming

    2005-01-01

    With the increasingly fierce competition in the deregulated Energy Market, the optimization of outage duration has become one of the focal points for the Nuclear Power Plant owners around the world. People are seeking various ways to shorten the outage duration of NPP. Great efforts have been made in the Light Water Reactor (LWR) family with the concept of benchmarking and evaluation, which great reduced the outage duration and improved outage performance. The average capacity factor of LWRs has been greatly improved over the last three decades, which now is close to 90%. CANDU (Pressurized Heavy Water Reactor) stations, with its unique feature of on power refueling, of nuclear fuel remaining in the reactor all through the planned outage, have given raise to more stringent safety requirements during planned outage. In addition, the above feature gives more variations to the critical path of planned outage in different station. In order to benchmarking again the best practices in the CANDU stations, Third Qinshan Nuclear Power Company (TQNPC) have initiated the benchmarking program among the CANDU stations aiming to standardize the outage maintenance windows and optimize the outage duration. The initial benchmarking has resulted the optimization of outage duration in Qinshan CANDU NPP and the formulation of its first long-term outage plan. This paper describes the benchmarking works that have been proven to be useful for optimizing outage duration in Qinshan CANDU NPP, and the vision of further optimize the duration with joint effort from the CANDU community. (authors)

  19. Homogeneous Thorium Fuel Cycles in Candu Reactors

    Energy Technology Data Exchange (ETDEWEB)

    Hyland, B.; Dyck, G.R.; Edwards, G.W.R.; Magill, M. [Chalk River Laboratories, Atomic Energy of Canada Limited (Canada)

    2009-06-15

    The CANDU{sup R} reactor has an unsurpassed degree of fuel-cycle flexibility, as a consequence of its fuel-channel design, excellent neutron economy, on-power refueling, and simple fuel bundle [1]. These features facilitate the introduction and full exploitation of thorium fuel cycles in Candu reactors in an evolutionary fashion. Because thorium itself does not contain a fissile isotope, neutrons must be provided by adding a fissile material, either within or outside of the thorium-based fuel. Those same Candu features that provide fuel-cycle flexibility also make possible many thorium fuel-cycle options. Various thorium fuel cycles can be categorized by the type and geometry of the added fissile material. The simplest of these fuel cycles are based on homogeneous thorium fuel designs, where the fissile material is mixed uniformly with the fertile thorium. These fuel cycles can be competitive in resource utilization with the best uranium-based fuel cycles, while building up a 'mine' of U-233 in the spent fuel, for possible recycle in thermal reactors. When U-233 is recycled from the spent fuel, thorium-based fuel cycles in Candu reactors can provide substantial improvements in the efficiency of energy production from existing fissile resources. The fissile component driving the initial fuel could be enriched uranium, plutonium, or uranium-233. Many different thorium fuel cycle options have been studied at AECL [2,3]. This paper presents the results of recent homogeneous thorium fuel cycle calculations using plutonium and enriched uranium as driver fuels, with and without U-233 recycle. High and low burnup cases have been investigated for both the once-through and U-233 recycle cases. CANDU{sup R} is a registered trademark of Atomic Energy of Canada Limited (AECL). 1. Boczar, P.G. 'Candu Fuel-Cycle Vision', Presented at IAEA Technical Committee Meeting on 'Fuel Cycle Options for LWRs and HWRs', 1998 April 28 - May 01, also Atomic Energy

  20. Evaluation of fuel performance for fresh and aged CANDU reactor

    Energy Technology Data Exchange (ETDEWEB)

    Jung, Jong Yeob; Bae, Jun Ho; Park, Joo Hwan [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2012-10-15

    Like all other industrial plants, nuclear power plants also undergo degradations, so called ageing, with their operation time. Accordingly, in the recent safety analysis for a refurbished Wolsong 1 NPP, various ageing effects were incorporated into the hydraulic models of a number of the components in the primary heat transport system for conservatism. The ageing data of thermal-hydraulic components for 11 EFPY of Wolsong 1 were derived by using NUCIRC code based on the site operation data and they were modified to the appropriate input data for CATHENA code which is a thermal hydraulic code for a postulated accident analysis. This paper deals with the ageing effect of the PHTS (primary heat transport system) of CANDU reactor on the fuel performance during the normal operation. Initial conditions for fuel performance analysis were derived from the thermal-hydraulic analysis for both fresh and aged core models. Here, fresh core means a core state just right after the refurbishment and the aged core is 11 EFPY state after the refurbishment of Wolsong 1. The fuel performance was analyzed by using ELESTRES code for both fresh and aged core state and the results were compared in order to verify the ageing effect of CANDU HTS on the fuel performance.

  1. CANDU radiotoxicity inventories estimation: A calculated experiment cross-check for data verification and validation

    International Nuclear Information System (INIS)

    Pavelescu, Alexandru Octavian; Cepraga, Dan Gabriel

    2007-01-01

    This paper is related to the Clearance Potential Index, Ingestion and Inhalation Hazard Factors of the nuclear spent fuel and radioactive wastes. This study required a complex activity that consisted of various phases such us: the acquisition, setting up, validation and application of procedures, codes and libraries. The paper reflects the validation phase of this study. Its objective was to compare the measured inventories of selected actinide and fission products radionuclides in an element from a Pickering CANDU reactor with inventories predicted using a recent version of the ORIGEN-ARP from SCALE 5 coupled with the time dependent cross sections library, CANDU 28.lib, produced by the sequence SAS2H of SCALE 4.4a. In this way, the procedures, codes and libraries for the characterization of radioactive material in terms of radioactive inventories, clearance, and biological hazard factors are being qualified and validated, in support for the safety management of the radioactive wastes. (authors)

  2. Application of Sub-cooled Boiling Model to Thermal-hydraulic Analysis Inside a CANDU-6 Fuel Channel

    International Nuclear Information System (INIS)

    Kim, Man Woong; Lee, Sang Kyu; Kim, Hyun Koon; Yoo, Kun Joong; Kang, Hyoung Chul; Yoo, Seong Yeon

    2007-01-01

    Forced convection nucleate boiling is encountered in heat exchangers during normal and non-nominal modes of operation in pressurized water or boiling water reactors (PWRs or BWRs). If the wall temperature of the piping is higher than the saturation temperature of the nearby liquid, nucleate boiling occurs. In this regime, bubbles are formed at the wall. Their growth is promoted by the wall superheat (the difference between the wall and saturation temperatures), and they depart from the wall as a result of gravitational and liquid inertia forces. If the bulk liquid is subcooled, condensation at the bubble-liquid interface takes place and the bubble may collapse. This convection nucleate boiling is called as a sub-cooled nucleate boiling. As for the fuel channel of a CANDU 6 reactor, forced convection nucleate boiling models for flows along fuel elements enclosed inside typical CANDU-6 fuel channel has encountered difficulties due to the modeling of local effects along the horizontal channel. Therefore, the subcooled nucleate boiling has been modeled through temperature driven boiling heat and mass transfer, using a model developed at Rensselaer Polytechnic Institute. The objectives of this study are: (i) to investigate a proposed sub-cooled boiling model developed at Rensselaer Polytechnic Institute and (ii) to apply against a experiment and (iii) to predict local distributions of flow fields for the actual fuel channel geometries of CANDU-6 reactors. The numerical implementation is conducted using by the FLUENT 6.2 CFD computer code

  3. Assessment of CANDU feeders subject to flow accelerated corrosion

    Energy Technology Data Exchange (ETDEWEB)

    Iyer, S. [Atomic Energy of Canada Ltd., Mississauga, Ontario (Canada); Slade, J.P. [New Brunswick Power, Point Lepreau Generating Station, Lepreau, New Brunswick (Canada)

    2003-07-01

    'Full Text:' Inspections of CANDU feeders have indicated greater than expected wall thinning of outlet feeders. This wall thinning is attributed to Flow-Accelerated Corrosion (FAC). The rate of wall loss due to FAC is highest in the close radius bends near the end fitting. The minimum allowed thickness for a feeder pipes is based on design pressure during the design stage. Extended operation of the thinned feeders beyond their design basis, i.e., operation of feeders with thickness below design pressure based minimum thickness has economic benefits for the utilities. In such cases, it is important to establish the remaining life and evaluate the adequacy of the components for safe operation. ASME Code Case N-597 provides the guidelines for acceptance for continued service of Classes 2 and 3 piping components experiencing wall thinning during operation. However, for Class 1 systems, the Code Case recommends that the owner develop the methodology and criteria for the assessment of wall thinning. Therefore, under the CANDU Owner's Group's (COG) Feeder Integrity Joint Program (FIJP), the 'Fitness for Service Guidelines (FFSG) for Feeders Affected by Wall Thinning in Operating CANDU Reactors' was developed and subsequently conditionally approved by CNSC. This paper illustrates the underlying concepts in the FFSG methodology and its benefits to utilities. Specific examples of the application and benefits of the FFSG at Point Lepreau G.S. are described in this paper. The assessment of feeders is based on the requirements of the construction Code (Section III of the ASME Boiler and Pressure Vessel Code): The following points briefly describe the assessment methodology. Satisfying the requirements of NB-3650 for design and service loadings are sufficient for continued service and extended life if the predicted minimum wall thickness of the component is greater than or equal to 90% of the pressure based thickness calculated as per NB-3641. The B

  4. Implementation of Wolsong Pump Model, Pressure Tube Deformation Model and Off-take Model into MARS Code for Regulatory Auditing of CANDU Reactors

    Energy Technology Data Exchange (ETDEWEB)

    Yoon, C.; Rhee, B. W.; Chung, B. D. [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of); Cho, Y. J.; Kim, M. W. [Korea Institute of Nuclear Safety, Daejeon (Korea, Republic of)

    2008-05-15

    Korea currently has four operating units of the CANDU-6 type reactor in Wolsong. However, the safety assessment system for CANDU reactors has not been fully established due to lack of self-reliance technology. Although the CATHENA code had been introduced from AECL, it is undesirable to use vendor's code for regulatory auditing analysis. In Korea, the MARS code has been developed for decades and is being considered by KINS as a thermal hydraulic regulatory auditing tool for nuclear power plants. Before this decision, KINS (Korea Institute of Nuclear Safety) had developed RELAP5/MOD3/CANDU code for CANDU safety analyses by modifying the model of existing PWR auditing tool, RELAP5/MOD3. The main purpose of this study is to transplant the CANDU models of RELAP5/MOD3/CANDU code to MARS code including quality assurance of the developed models. This first part of the research series presents the implementation and verification of the Wolsong pump model, the pressure tube deformation model, and the off-take model for arbitrary-angled branch pipes.

  5. Implementation of Wolsong Pump Model, Pressure Tube Deformation Model and Off-take Model into MARS Code for Regulatory Auditing of CANDU Reactors

    International Nuclear Information System (INIS)

    Yoon, C.; Rhee, B. W.; Chung, B. D.; Cho, Y. J.; Kim, M. W.

    2008-01-01

    Korea currently has four operating units of the CANDU-6 type reactor in Wolsong. However, the safety assessment system for CANDU reactors has not been fully established due to lack of self-reliance technology. Although the CATHENA code had been introduced from AECL, it is undesirable to use vendor's code for regulatory auditing analysis. In Korea, the MARS code has been developed for decades and is being considered by KINS as a thermal hydraulic regulatory auditing tool for nuclear power plants. Before this decision, KINS (Korea Institute of Nuclear Safety) had developed RELAP5/MOD3/CANDU code for CANDU safety analyses by modifying the model of existing PWR auditing tool, RELAP5/MOD3. The main purpose of this study is to transplant the CANDU models of RELAP5/MOD3/CANDU code to MARS code including quality assurance of the developed models. This first part of the research series presents the implementation and verification of the Wolsong pump model, the pressure tube deformation model, and the off-take model for arbitrary-angled branch pipes

  6. Evaluation of hydride blisters in zirconium pressure tube in CANDU reactor

    International Nuclear Information System (INIS)

    Cheong, Y. M.; Kim, Y. S.; Gong, U. S.; Kwon, S. C.; Kim, S. S.; Choo, K.N.

    2000-09-01

    When the garter springs for maintaining the gap between the pressure tube and the calandria tube are displaced in the CANDU reactor, the sagging of pressure tube results in a contact to the calandria tube. This causes a temperature difference between the inner and outer surface of the pressure tube. The hydride can be formed at the cold spot of outer surface and the volume expansion by hydride dormation causes the blistering in the zirconium alloys. An incident of pressure tube rupture due to the hydride blisters had happened in the Canadian CANDU reactor. This report describes the theoretical development and models on the formation and growth of hydride blister and some experimental results. The evaluation methodology and non-destructive testing for hydride blister in operating reactors are also described

  7. Evaluation of hydride blisters in zirconium pressure tube in CANDU reactor

    Energy Technology Data Exchange (ETDEWEB)

    Cheong, Y M; Kim, Y S; Gong, U S; Kwon, S C; Kim, S S; Choo, K N

    2000-09-01

    When the garter springs for maintaining the gap between the pressure tube and the calandria tube are displaced in the CANDU reactor, the sagging of pressure tube results in a contact to the calandria tube. This causes a temperature difference between the inner and outer surface of the pressure tube. The hydride can be formed at the cold spot of outer surface and the volume expansion by hydride dormation causes the blistering in the zirconium alloys. An incident of pressure tube rupture due to the hydride blisters had happened in the Canadian CANDU reactor. This report describes the theoretical development and models on the formation and growth of hydride blister and some experimental results. The evaluation methodology and non-destructive testing for hydride blister in operating reactors are also described.

  8. Hyperfine 3D neutronic calculations in CANDU supercells

    International Nuclear Information System (INIS)

    Balaceanu, V.; Aioanei, L.; Pavelescu, M.

    2010-01-01

    For an accurate evaluation of the fuel performances, it is very important to have capability to calculate the three dimensional spatial flux distributions in the fuel bundle. According this issue, in our Institute, a multigroup calculation methodology named WIMS-PIJXYZ was especially developed for estimating the local neutronic parameters in CANDU cell/supercells. The objective of this paper is to present this calculation methodology and to use it in performing some hyperfine neutronic calculations in CANDU type supercells. More exactly, after a short description for the WIMS-PIJXYZ methodology, the end effect for some CANDU fuel bundles is estimated. The WIMS-PIJXYZ methodology is based on WIMS and PIJXYZ transport codes. WIMS is a standard lattice-cell code and it is used for generating the multigroup macroscopic cross sections for the materials in the fuel cells. For obtaining the flux and power distributions in CANDU fuel bundles the PIJXYZ code is used. This code is consistent with WIMS lattice-cell calculations and allows a good geometrical representation of the CANDU bundle in three dimensions. The end effect consists in the increasing of the thermal neutron flux in the end region and the increasing of power in the end of the fuel rod. The region separating the CANDU fuel in two adjoining bundles in a channel is called the 'end region' and the end of the last pellet in the fuel stack adjacent to the end region is called the 'fuel end'. The end effect appears because the end region of the bundle is made up of coolant and Zircaloy-4, a very low neutron absorption material. To estimate the end effect, the flux peaking factors and the power peaking factors are calculated. It was taken in consideration CANDU Standard (Natural Uranium, with 37 elements) fuel bundles. In the end of the paper, the results obtained by WIMS-PIJXYZ methodology with the similar LEGENTR results are compared. The comparative analysis shows a good agreement. (authors)

  9. CANDU market prospects

    International Nuclear Information System (INIS)

    Kakaria, B.K.

    1994-01-01

    This 1994 survey of prospective markets for CANDU reactors discusses prospects in Turkey, Thailand, the Philippines, Korea, Indonesia, China and Egypt, and other opportunities, such as in fuel cycles and nuclear safety. It was concluded that foreign partners would be needed to help with financing

  10. Assessment of core characteristics during transition from 37-element fuel to CANFLEX-NU fuel in CANDU 6

    International Nuclear Information System (INIS)

    Jeong, Chang Joon; Suk, Ho Chun

    2002-01-01

    A transition from 37-element natural uranium fuel to CANFLEX-NU fuel has been modeled in a 1200-day time-dependent fuel management simulation for a CANDU 6 reactor. The simulation was divided into three parts. The pre-transition period extended from 0 to 300 FPD, in which the reactor was fuelled only with standard 37-element fuel bundles. In the transition period, refueling took place only with the CANFLEX-NU fuel bundle. The transition stage lasted from 300 to 920 FPD, at which point all of the 37-element fuel in the core had been replaced by CANFLEX-NU fuel bundle. In the post-transition phase, refueling continued with CANFLEX-NU fuel until 1200 FPD, to arrive at estimate of the equilibrium core characteristics with CANFLEX-NU fuel. Simulation results show that the CANFLEX-NU fuel bundle has a operational compatibility with the CANDU 6 reactor during the transition core, and also show that the transition core from 37-element natural uranium fuel to CANFLEX-NU can be operated without violating any license limit of the CANDU 6 reactor

  11. A model for fission product distribution in CANDU fuel

    International Nuclear Information System (INIS)

    Muzumdar, A.P.

    1983-01-01

    This paper describes a model to estimate the distribution of active fission products among the UO 2 grains, grain-boundaries, and the free void spaces in CANDU fuel elements during normal operation. This distribution is required for the calculation of the potential release of activity from failed fuel sheaths during a loss-of-coolant accident. The activity residing in the free spaces (''free'' inventory) is available for release upon sheath rupture, whereas relatively high fuel temperatures and/or thermal shock are required to release the activity in the grain boundaries or grains. A preliminary comparison of the model with the data from in-reactor sweep-gas experiments performed in Canada yields generally good agreement, with overprediction rather than under prediction of radiologically important isotopes, such as I 131 . The model also appears to generally agree with the ''free'' inventory release calculated using ANS-5.4. (author)

  12. Experience of oil in CANDU moderator during A831 planned outage at Bruce Power

    International Nuclear Information System (INIS)

    Ma, G.; Nashiem, R.; Matheson, S.; Stuart, C.; Roberts, J.G.

    2011-01-01

    In their address to the Nuclear Plant Chemistry Conference 2009, Bruce Power staff will describe the effects of oil ingress to the moderator of a CANDU reactor. During the A831 planned outage of Bruce Power Unit 3, an incident of oil ingress into moderator was discovered on Oct 17, 2008. An investigation identified the cause of the oil ingress. Atomic Energy of Canada Ltd. (AECL) assessed operability of the reactor with the oil present and made recommendations with respect to the effect on unit start-up with oil present. The principal concern was the radiolytic generation of deuterium from the breakdown of the oil in-core. Various challenges were presented during start-up which were overcome via innovative approaches. The subsequent actions and consequential effects on moderator chemistry are discussed in this paper. Examination of the plant chemistry data revealed some interesting aspects of moderator system chemistry under upset conditions which will also be presented. (author)

  13. Experience of oil in CANDU moderator during A831 planned outage at Bruce Power

    Energy Technology Data Exchange (ETDEWEB)

    Ma, G.; Nashiem, R.; Matheson, S. [Bruce Power, Tiverton, Ontario (Canada); Stuart, C. [Atomic Energy of Canada Limited, Chalk River, Ontario (Canada); Roberts, J.G. [CANTECH Associates Ltd., Burlington, Ontario (Canada)

    2011-03-15

    In their address to the Nuclear Plant Chemistry Conference 2009, Bruce Power staff will describe the effects of oil ingress to the moderator of a CANDU reactor. During the A831 planned outage of Bruce Power Unit 3, an incident of oil ingress into moderator was discovered on Oct 17, 2008. An investigation identified the cause of the oil ingress. Atomic Energy of Canada Ltd. (AECL) assessed operability of the reactor with the oil present and made recommendations with respect to the effect on unit start-up with oil present. The principal concern was the radiolytic generation of deuterium from the breakdown of the oil in-core. Various challenges were presented during start-up which were overcome via innovative approaches. The subsequent actions and consequential effects on moderator chemistry are discussed in this paper. Examination of the plant chemistry data revealed some interesting aspects of moderator system chemistry under upset conditions which will also be presented. (author)

  14. Experimental and thermodynamic studies of beryllium replacement materials for CANDU brazed joints

    Energy Technology Data Exchange (ETDEWEB)

    Potter, K.N.; Ferrier, G.A.; Corcoran, E.C., E-mail: Kieran.Potter@rmc.ca [Royal Military College of Canada, Kingston, ON (Canada)

    2015-07-01

    Currently, appendages are joined to CANDU fuel elements via a brazing process, which uses beryllium as the filler material. A potential reduction in the occupational limit on airborne beryllium particulates has motivated research into alternative brazing materials. To this end, the Canadian nuclear industry has funded an initiative to identify and evaluate the suitability of several candidate materials. This work describes contributions toward the assessment of alternative brazing materials from the Royal Military College of Canada. Thermodynamic modelling was performed to predict the aqueous behaviour of each candidate material in CANDU coolant conditions characteristic of reactor shutdown, and experiments are underway to support modelling predictions. These results will assist in selecting a suitable replacement material for beryllium. (author)

  15. A Preliminary Assessment of the Adjuster Rod Depletion Effect in the CANDU Reactor

    International Nuclear Information System (INIS)

    Kim, Yonghee; Roh, Gyuhong; Kim, Won Young; Kim, Hak Sung; Park, Joo Hwan

    2008-01-01

    Lifetime of the Wolsong-1 CANDU reactor, which will be shutdown in April, 2009. Major reactor components such as the pressure tube are to be replaced and it is expected that the CANDU reactor can be operated for additional 25-30 years. Meanwhile, all the reactivity devices including the adjuster rods (ADJ) are supposed to be continuously used without any change. In the CANDU reactor, 21 stainless steel (SS) ADJs are used to control the core power distribution and compensate for some reactivity loss during several abnormal cases. The ADJs are normally fully inserted and the SS absorber should undergo a slow depletion through neutron irradiation for a long time. In April, 2009, the accumulated FPY (Full Power Day) of Wolsong-1 is about 23 years. Depletion of ADJs should result in a smaller ADJ worth and a higher fuel burnup and the core power distribution should also be affected by the ADJ depletion. In this work, the effects of the ADJ depletion have been assessed in terms of ADJ worth, time-average core characteristics

  16. A generalized perturbation program for CANDU reactor

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Do Heon; Kim, Jong Kyung [Hanyang University, Seoul (Korea, Republic of); Choi, Hang Bok; Roh, Gyu Hong [Korea Atomic Energy Research Institute, Taejon (Korea, Republic of); Yang, Won Sik [Chosun University, Kwangju (Korea, Republic of)

    1999-12-31

    A generalized perturbation program has been developed for the purpose of estimating zonal power variation of a CANDU reactor upon refueling operation. The forward and adjoint calculation modules of RFSP code were used to construct the generalized perturbation program. The numerical algorithm for the generalized adjoint flux calculation was verified by comparing the zone power estimates upon refueling with those of forward calculation. It was, however, noticed that the truncation error from the iteration process of the generalized adjoint flux is not negligible. 2 refs., 1 figs., 1 tab. (Author)

  17. A generalized perturbation program for CANDU reactor

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Do Heon; Kim, Jong Kyung [Hanyang University, Seoul (Korea, Republic of); Choi, Hang Bok; Roh, Gyu Hong [Korea Atomic Energy Research Institute, Taejon (Korea, Republic of); Yang, Won Sik [Chosun University, Kwangju (Korea, Republic of)

    1998-12-31

    A generalized perturbation program has been developed for the purpose of estimating zonal power variation of a CANDU reactor upon refueling operation. The forward and adjoint calculation modules of RFSP code were used to construct the generalized perturbation program. The numerical algorithm for the generalized adjoint flux calculation was verified by comparing the zone power estimates upon refueling with those of forward calculation. It was, however, noticed that the truncation error from the iteration process of the generalized adjoint flux is not negligible. 2 refs., 1 figs., 1 tab. (Author)

  18. Low Power Shutdown PSA for CANDU Type Plants

    Energy Technology Data Exchange (ETDEWEB)

    Bae, Yeon Kyoung; Kim, Myung Su [KHNP CRI, Daejeon (Korea, Republic of)

    2016-10-15

    KHNP also have concentrated on full power PSA. Some recently constructed OPR1000 type plants and APR1400 type plants have performed the low power and shutdown (LPSD) PSA. The purpose of LPSD PSA is to identify the main contributors on the accident sequences of core damage and to find the measure of safety improvement. After the Fukushima accident, Korean regulatory agency required the shutdown severe accident management guidelines (SSAMG) development for safety enhancement. For the reliability of SSAMG, KHNP should develop the LPSD PSA. Especially, the LPSD PSA for CANDU type plant had developed for the first time in Korea. This paper illustrates how the LPSD PSA for CANDU type developed and the core damage frequency (CDF) is different with that of full power PSA. KHNP performed LPSD PSA to develop the SSAMG after the Fukushima accidents. The results show that risk at the specific operation mode during outage is higher than that of full power operation. Also, the results indicated that recovery failure of class 4 power at the POS 5A, 5B contribute dominantly to the total CDF from importances analysis. LPSD PSA results such as CDF with initiating events and POSs, risk results with plant damage state, and containment failure probability and frequency with POSs can be used by inputs for developing the SSAMG.

  19. An Evaluation of a Fission Product Inventory for CANDU Fuels

    International Nuclear Information System (INIS)

    Jung, Jong Yeob; Park, Joo Hwan

    2007-01-01

    Fission products are released by two processes when a single channel accident occurs. One is a 'prompt release' and the other is a 'delayed release'. Prompt release assumes that the gap inventory of the fuel elements is released by a fuel element failure at the time of an accident. Delayed release assumes that the inventories within the grain or at the grain boundary are released after a accident due to a diffusion through grains, an oxidation of the fuel and an interaction between the fuel and the Zircaloy sheath. Therefore, the calculation of a fission product inventory and its distribution in a fuel during a normal operating is the starting point for the assessment of a fission product release for single channel accidents. In this report, the fission product inventories and their distributions within s fuel under a normal operating condition are evaluated for three types of CANDU fuels such as the 37 element fuel, CANFLEX-NU and CANFLEX-RU fuel bundles in the 'limiting channel'. To accomplish the above mentioned purposes, the basic power histories for each type of CANDU fuel were produced and the fission product inventories were calculated by using the ELESTRES code

  20. Evaluation of a leaking crack in an irradiated CANDU pressure tube

    International Nuclear Information System (INIS)

    Coleman, C.E.; Simpson, L.A.

    1988-06-01

    Leak-before-break is used in CANDU reactors as part of the defence against rupture of the pressure tubes. Two important features of this technique are the action time available for detection of a leaking crack and the size of the leak allowing crack location. Support for continued reliance on leak-before-break is being obtained from experiments, on irradiated Zr-2.5 Nb pressure tubes attached to their end fittings, that simulate the behaviour of a leaking crack in a reactor. At reactor operating temperatures leaking cracks grow more slowly than dry cracks in the laboratory because they are cooled when pressurised water flashes to steam on their surface. These cracks remain stable till they are at least 70 mm long. From the results of these experiments the action time is at least 100 h. The leak rate increases rapidly when a through-wall crack extends a small amount, thus greatly assisting with crack location

  1. Three Mile Island - a review of the accident and its implications for CANDU safety

    International Nuclear Information System (INIS)

    Pannell, R.J.; Campbell, F.R.

    1980-03-01

    After the accident at the Three Mile Island-2 reactor all Canadian owners of CANDU nuclear power plants were asked by the Atomic Energy Control Board (AECB) to conduct a design review to assess the reliability of feedwater supply to boilers, the availability of backup cooling systems, and the adequacy of routine and emergency operating procedures. The authors studied the available information on the accident and the replies received from licensees. Their report is in three sections: a description of the accident, the authors' opinions of the underlying causes, and recommendations to the AECB regarding what might be done to confirm or improve the safety of CANDU plants

  2. Enhanced CANDU6: Reactor and fuel cycle options - Natural uranium and beyond

    International Nuclear Information System (INIS)

    Ovanes, M.; Chan, P. S. W.; Mao, J.; Alderson, N.; Hopwood, J. M.

    2012-01-01

    The Enhanced CANDU 6 R (ECo R ) is the updated version of the well established CANDU 6 family of units incorporating improved safety characteristics designed to meet or exceed Generation III nuclear power plant expectations. The EC6 retains the excellent neutron economy and fuel cycle flexibility that are inherent in the CANDU reactor design. The reference design is based on natural uranium fuel, but the EC6 is also able to utilize additional fuel options, including the use of Recovered Uranium (RU) and Thorium based fuels, without requiring major hardware upgrades to the existing control and safety systems. This paper outlines the major changes in the EC6 core design from the existing C6 design that significantly enhance the safety characteristics and operating efficiency of the reactor. The use of RU fuel as a transparent replacement fuel for the standard 37-el NU fuel, and several RU based advanced fuel designs that give significant improvements in fuel burnup and inherent safety characteristics are also discussed in the paper. In addition, the suitability of the EC6 to use MOX and related Pu-based fuels will also be discussed. (authors)

  3. Seismic analysis during development stage of CANDU Model 2 fueling machine design

    International Nuclear Information System (INIS)

    Lee, L.S.S.; Mansfield, R.A.

    1989-01-01

    The CANDU Model 3 is a new small reactor presently being designed. This reactor is 450 MWe, and as with current operating CANDU's, is based on a heavy water moderated and cooled system using on-power fuelling for the once-through natural uranium fuel cycle. The CANDU 3 Standard plant is designed to be adaptable to a range of world-wide site conditions, i.e. for a peak ground acceleration of 0.3 g and a wide range of soft, medium and hard foundation medium properties. Consequently, a conservatism in the design of structure and equipment is accounted by using enveloped floor response spectra generated by the soil-structure interaction analysis. Seismic qualification of the fuelling machine (F/M) and its support structure are an essential design requirement for maintaining the integrity of the reactor coolant heat transport system (HTS) pressure boundary and the service ports penetrating the containment structure during on-power fueling. This paper deals with the initial conceptual phase of design where the details of the design are in fundamental outline form only and basic mass distribution plus layout geometry is defined

  4. Dimensional measurement of fresh fuel bundle for CANDU reactor

    International Nuclear Information System (INIS)

    Jo, Chang Keun; Cho, Moon Sung; Suk, Ho Chun; Koo, Dae Seo; Jun, Ji Su; Jung, Jong Yeob

    2005-01-01

    This report describes the results of the dimensional measurement of fresh fuel bundles for the CANDU reactor in order to estimate the integrity of fuel bundle in two-phase flow in the CANDU-6 fuel channel. The dimensional measurements of fuel bundles are performed by using the 'CANDU Fuel In-Bay Inspection and Dimensional Measurement System', which was developed by this project. The dimensional measurements are done from February 2004 to March 2004 in the CANDU fuel storage of KNFC for the 36 fresh fuel bundles, which are produced by KNFC and are waiting for the delivery to the Wolsong-3 plant. The detail items of dimensional measurements are included fuel rod and bearing pad profiles of the outer ring in fuel bundle, diameter of fuel bundle, bowing of fuel bundle, fuel rod length, and surface profile of end plate profile. The measurement data will be compared with those of the post-irradiated bundles cooled in Wolsong-3 NPP spent fuel pool by using the same bundles and In-Bay Measurement System. So, this analysis of data will be applied for the evaluation of fuel bundle integrity in two-phase flow of the CANDU-6 fuel channel

  5. Construction of dynamic model of CANDU-SCWR using moving boundary method

    International Nuclear Information System (INIS)

    Sun Peiwei; Jiang Jin; Shan Jianqiang

    2011-01-01

    Highlights: → A dynamic model of a CANDU-SCWR is developed. → The advantages of the moving boundary method are demonstrated. → The dynamic behaviours of the CANDU-SCWR are obtained by simulation. → The model can predict the dynamic behaviours of the CANDU-SCWR. → Linear dynamic models for CANDU-SCWR are derived by system identification techniques. - Abstract: CANDU-SCWR (Supercritical Water-Cooled Reactor) is one type of Generation IV reactors being developed in Canada. Its dynamic characteristics are different from existing CANDU reactors due to the supercritical conditions of the coolant. To study the behaviours of such reactors under disturbances and to design adequate control systems, it is essential to have an accurate dynamic model to describe such a reactor. One dynamic model is developed for CANDU-SCWR in this paper. In the model construction process, three regions have been considered: Liquid Region I, Liquid Region II and Vapour Region, depending on bulk and wall temperatures being higher or lower the pseudo-critical temperature. A moving boundary method is used to describe the movement of boundaries across these regions. Some benefits of adopting moving boundary method are illustrated by comparing with the fixed boundary method. The results of the steady-state simulation based on the developed model agree well with the design parameters. The transient simulations demonstrate that the model can predict the dynamic behaviours of CANDU-SCWR. Furthermore, to investigate the responses of the reactor to small amplitude perturbations and to facilitate control system designs, a least-square based system identification technique is used to obtain a set of linear dynamic models around the design point. The responses based on the linear dynamic models are validated with simulation results from nonlinear CANDU-SCWR dynamic model.

  6. Study on the use of slightly enriched uranium fuel cycle in an existing CANDU 6 reactor

    Energy Technology Data Exchange (ETDEWEB)

    Yeom, Choong Sub; Kim, Hyun Dae [Institute for Advanced Engineering, Seoul (Korea, Republic of)

    1998-12-31

    To test the viability of CANFLEX-SEU bundles in an existing CANDU 6 reactor, core follow-up simulation has been carried out using the reactor fueling simulation program of the CANDU 6, RFSP computer code, and a lattice physics code, WIMS-AECL. During the core follow-up, bundle and channel powers and zone levels have been checked against their operating limits at each simulation. It is observed from the simulation results that an equilibrium core loaded with 0.9 w/o CANFLEX-SEU bundles could be refueled and maintained for 550 FPD without any significant violations in the channel and bundle power limits and the permissible operating range of the liquid zone controllers. 8 refs., 2 figs., 1 tab. (Author)

  7. Study on the use of slightly enriched uranium fuel cycle in an existing CANDU 6 reactor

    Energy Technology Data Exchange (ETDEWEB)

    Yeom, Choong Sub; Kim, Hyun Dae [Institute for Advanced Engineering, Seoul (Korea, Republic of)

    1997-12-31

    To test the viability of CANFLEX-SEU bundles in an existing CANDU 6 reactor, core follow-up simulation has been carried out using the reactor fueling simulation program of the CANDU 6, RFSP computer code, and a lattice physics code, WIMS-AECL. During the core follow-up, bundle and channel powers and zone levels have been checked against their operating limits at each simulation. It is observed from the simulation results that an equilibrium core loaded with 0.9 w/o CANFLEX-SEU bundles could be refueled and maintained for 550 FPD without any significant violations in the channel and bundle power limits and the permissible operating range of the liquid zone controllers. 8 refs., 2 figs., 1 tab. (Author)

  8. Heat transport inventory monitoring for CANDU-PHW reactors

    International Nuclear Information System (INIS)

    Hussein, E.; Luxat, J.C.

    1984-01-01

    A computer-based D 2 O coolant inventory monitoring system proposed for implementation on the digital computer controllers at Ontario Hydro's CANDU generating units is discussed. By monitoring process parameters and utilizing probabilistically-based decision algorithms, timely indication of any significant loss of D 2 O inventory will be provided to the operator. The monitoring is performed in a co-ordinated manner such that D 2 O losses from either the heat transport system or the inventory control system can be detected. (orig.)

  9. Development of Off-take Model, Subcooled Boiling Model, and Radiation Heat Transfer Input Model into the MARS Code for a Regulatory Auditing of CANDU Reactors

    Energy Technology Data Exchange (ETDEWEB)

    Yoon, C.; Rhee, B. W.; Chung, B. D. [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of); Ahn, S. H.; Kim, M. W. [Korea Institute of Nuclear Safety, Daejeon (Korea, Republic of)

    2009-05-15

    Korea currently has four operating units of the CANDU-6 type reactor in Wolsong. However, the safety assessment system for CANDU reactors has not been fully established due to a lack of self-reliance technology. Although the CATHENA code had been introduced from AECL, it is undesirable to use a vendor's code for a regulatory auditing analysis. In Korea, the MARS code has been developed for decades and is being considered by KINS as a thermal hydraulic regulatory auditing tool for nuclear power plants. Before this decision, KINS (Korea Institute of Nuclear Safety) had developed the RELAP5/MOD3/CANDU code for CANDU safety analyses by modifying the model of the existing PWR auditing tool, RELAP5/MOD3. The main purpose of this study is to transplant the CANDU models of the RELAP5/MOD3/CANDU code to the MARS code including a quality assurance of the developed models.

  10. Development of Off-take Model, Subcooled Boiling Model, and Radiation Heat Transfer Input Model into the MARS Code for a Regulatory Auditing of CANDU Reactors

    International Nuclear Information System (INIS)

    Yoon, C.; Rhee, B. W.; Chung, B. D.; Ahn, S. H.; Kim, M. W.

    2009-01-01

    Korea currently has four operating units of the CANDU-6 type reactor in Wolsong. However, the safety assessment system for CANDU reactors has not been fully established due to a lack of self-reliance technology. Although the CATHENA code had been introduced from AECL, it is undesirable to use a vendor's code for a regulatory auditing analysis. In Korea, the MARS code has been developed for decades and is being considered by KINS as a thermal hydraulic regulatory auditing tool for nuclear power plants. Before this decision, KINS (Korea Institute of Nuclear Safety) had developed the RELAP5/MOD3/CANDU code for CANDU safety analyses by modifying the model of the existing PWR auditing tool, RELAP5/MOD3. The main purpose of this study is to transplant the CANDU models of the RELAP5/MOD3/CANDU code to the MARS code including a quality assurance of the developed models

  11. The use of digital computers in CANDU shutdown systems

    International Nuclear Information System (INIS)

    Gilbert, R.S.; Komorowski, C.W.

    1986-01-01

    This paper summarizes the application of computers in CANDU shutdown systems. A general description of systems that are already in service is presented along with a description of a fully computerized shutdown system which is scheduled to enter service in 1987. In reviewing the use of computers in the shutdown systems there are three functional areas where computers have been or are being applied. These are (i) shutdown system monitoring, (ii) parameter display and testing and (iii) shutdown initiation. In recent years various factors (References 1 and 2) have influenced the development and deployment of systems which have addressed two of these functions. At the present time a system is also being designed which addresses all of these areas in a comprehensive manner. This fully computerized shutdown system reflects the previous design, and licensing experience which was gained in earlier applications. Prior to describing the specific systems which have been designed a short summary of CANDU shutdown system characteristics is presented

  12. Natural uranium equivalent fuel an innovative design for proven CANDU technology

    Energy Technology Data Exchange (ETDEWEB)

    Pineiro, F.; Ho, K.; Khaial, A.; Boubcher, M.; Cottrell, C.; Kuran, S., E-mail: fabricia.pineiro@candu.com [Candu Energy Inc., Mississauga, ON (Canada); Zhenhua, Z.; Zhiliang, M. [Third Qinshan Nuclear Power Company, Haiyan, Zhejiang (China)

    2015-07-01

    The high neutron economy, on-power refuelling capability and fuel bundle design simplicity in CANDU reactors allow for the efficient utilization of alternative fuels. Candu Energy Inc. (Candu), in collaboration with the Third Qinshan Nuclear Power Company (TQNPC), the China North Nuclear Fuel Corporation (CNNFC), and the Nuclear Power Institute of China (NPIC), has successfully developed an advanced fuel called Natural Uranium Equivalent (NUE). This innovative design consists of a mixture of recycled and depleted uranium, which can be implemented in existing CANDU stations thereby bringing waste products back into the energy stream, increasing fuel resources diversity and reducing fuel costs. (author)

  13. A modal method for transient thermal analysis of CANDU fuel channel

    International Nuclear Information System (INIS)

    Park, J-W.; Muzumdar, A.J.

    1996-01-01

    The classical modal expansion technique has been applied to predict transient fuel and coolant temperatures under on-power conditions in a CANDU fuel channel. The temperature profile across the fuel pellet is assumed to be parabolic and fuel and coolant temperatures are expanded with Fourier series. The coefficient derivatives are written in state space form and solved by the Runge-Kutta method of fifth order. To validate the present model, the calculated fuel temperatures for several sample cases were compared with HOTSPOT-II, which employs a more rigorous finite-difference model. The agreement was found to be reasonable for the operational transients simulated. The advantage of the modal method is the fast computation speed for application to the real-time system such as the CANDU simulator which is being currently developed at the Institute for Advanced Engineering (IAE). (author)

  14. A flashing driven moderator cooling system for CANDU reactors: Experimental and computational results

    International Nuclear Information System (INIS)

    Khartabil, H.F.

    2000-01-01

    A flashing-driven passive moderator cooling system is being developed at AECL for CANDU reactors. Preliminary simulations and experiments showed that the concept was feasible at normal operating power. However, flow instabilities were observed at low powers under conditions of variable and constant calandria inlet temperatures. This finding contradicted code predictions that suggested the loop should be stable at all powers if the calandria inlet temperature was constant. This paper discusses a series of separate-effects tests that were used to identify the sources of low-power instabilities in the experiments, and it explores methods to avoid them. It concludes that low-power instabilities can be avoided, thereby eliminating the discrepancy between the experimental and code results. Two factors were found to be important for loop stability: (1) oscillations in the calandria outlet temperature, and (2) flashing superheat requirements, and the presence of nucleation sites. By addressing these factors, we could make the loop operate in a stable manner over the whole power range and we could obtain good agreement between the experimental and code results. (author)

  15. Advanced instrumentation and control systems for CANDU refurbishment

    International Nuclear Information System (INIS)

    Sklyar, V.; Bakhmach, I.; Kharchenko, V.; Andrashov, A.; Baranova, O.

    2011-01-01

    The purpose of the work is to discuss opportunities to modernize I and C systems of CANDU reactors on the base of Radiy's digital safety platform. This paper discusses the following topics: a business model for CANDU, I and C systems refurbishment, FPGA technology issues, comparison of different approaches to refurbish obsolete I and C systems. (author)

  16. Improving the service life and performance of CANDU fuel channels

    International Nuclear Information System (INIS)

    Causey, A.R.; Cheadle, B.A.; Coleman, C.E.; Price, E.G.

    1997-01-01

    The development objective for CANDU fuel channels is to produce a design that can operate for 40 years at 90% capacity. Steady progress toward this objective is being made. The factors that determine the life of the channel are reviewed and the processes necessary to achieve the objectives identified. Performance of future fuel channels will be enhanced by reduced operating costs, increased safety margins to postulated accident conditions, and reduced retubing costs compared to current channels. The approaches to these issues are discussed briefly in the paper. (author)

  17. The AECL operator companion

    International Nuclear Information System (INIS)

    Lupton, L.R.; Anderson, L.L.; Basso, R.A.J.

    1989-11-01

    As CANDU plants become more complex, and are operated under tighter constraints and for longer periods between outages, plant operations staff will have to absorb more information to correctly and rapidly respond to upsets. A development program is underway at AECL to use expert systems and interactive media tools to assist operations staff of existing and future CANDU plants. The complete system for plant information access and display, on-line advice and diagnosis, and interactive operating procedures is called the Operator Companion. A prototype, consisting of operator consoles, expert systems and simulation modules in a distributed architecture, is currently being developed to demonstrate the concepts of the Operator Companion

  18. Nuclear energy in Canada: the CANDU system

    International Nuclear Information System (INIS)

    Robertson, J.A.L.

    1979-10-01

    Nuclear electricity in Canada is generated by CANDU nuclear power stations. The CANDU reactor - a unique Canadian design - is fuelled by natural uranium and moderated by heavy water. The system has consistently outperformed other comparable nuclear power systems in the western world, and has an outstanding record of reliability, safety and economy. As a source of energy it provides the opportunity for decreasing our dependence on dwindling supplies of conventional fossil fuels. (auth)

  19. Safety benefits from CANDU reactor replacement - a case study

    International Nuclear Information System (INIS)

    Mottram, R.; Millard, J.W.F.; Purdy, P.

    2011-01-01

    Both total core replacement and core retubing have been used in the CANDU industry. For future plant refurbishments, based on experience both in new construction and in recent refurbishments, the concept of total core replacement has been revisited. This builds on practices for replacement of other large plant equipment like boilers. The Bruce CANDU reactors, with their local shield tanks built around the Calandria and containment closely located around that Calandria Shield Tank Assembly (CSTA), are believed to be good candidates for core replacement. A structured process was used to design a replacement CSTA suitable for Bruce A use. The work started with a study of opportunities for safety enhancements in the core. This progressed into design studies and related design assist safety analysis on the reactor. A key element of the work involved consideration of how verified features from later CANDU designs, and from our new reactor design work, could be tailored to fit this replacement core. The replacement reactor core brings in structural improvements in both calandria and end shield, and safety improvements like the natural circulation enhancing moderator cooling layout and further optimized reactivity layouts to improve shutdown system performance. Bruce Power are currently studying the business implications of this and retube techniques as part of preparation for future refurbishments. The work explained in this paper is in the context of the safety related changes and the work to choose and quantify them. (author)

  20. Safety benefits from CANDU reactor replacement. A case study

    International Nuclear Information System (INIS)

    Mottram, R.; Millard, J.W.F.; Purdy, P.

    2011-01-01

    Both total core replacement and core retubing have been used in the CANDU industry. For future plant refurbishments, based on experience both in new construction and in recent refurbishments, the concept of total core replacement has been revisited. This builds on practices for replacement of other large plant equipment like boilers. The Bruce CANDU reactors, with their local shield tanks built around the Calandria and containment closely located around that Calandria Shield Tank Assembly (CSTA), are believed to be good candidates for core replacement. A structured process was used to design a replacement CSTA suitable for Bruce A use. The work started with a study of opportunities for safety enhancements in the core. This progressed into design studies and related design assist safety analysis on the reactor. A key element of the work involved consideration of how verified features from later CANDU designs, and from our new reactor design work, could be tailored to fit this replacement core. The replacement reactor core brings in structural improvements in both calandria and end shield, and safety improvements like the natural circulation enhancing moderator cooling layout and further optimized reactivity layouts to improve shutdown system performance. Bruce Power are currently studying the business implications of this and retube techniques as part of preparation for future refurbishments. The work explained in this paper is in the context of the safety related changes and the work to choose and quantify them. (author)

  1. Proceedings of the third international conference on CANDU maintenance

    International Nuclear Information System (INIS)

    1995-01-01

    The third international conference on Candu maintenance included sessions on the following topics: predictive maintenance, reliability improvements, steam generator monitoring, tools and instrumentation, valve performance, fuel channel inspection and maintenance, steam generator maintenance, environmental qualification, predictive maintenance, instrumentation and control, steam generator cleaning, decontamination and radiation protection, inspection techniques, maintenance program strategies and valve packing experience, remote tooling/ robotics and fuel handling. The individual papers have been abstracted separately

  2. Proceedings of the third international conference on CANDU maintenance

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1996-12-31

    The third international conference on Candu maintenance included sessions on the following topics: predictive maintenance, reliability improvements, steam generator monitoring, tools and instrumentation, valve performance, fuel channel inspection and maintenance, steam generator maintenance, environmental qualification, predictive maintenance, instrumentation and control, steam generator cleaning, decontamination and radiation protection, inspection techniques, maintenance program strategies and valve packing experience, remote tooling/ robotics and fuel handling. The individual papers have been abstracted separately.

  3. Analysis of ASTEC code adaptability to severe accident simulation for CANDU type reactors

    International Nuclear Information System (INIS)

    Constantin, Marin; Rizoiu, Andrei

    2008-01-01

    In order to prepare the adaptation of the ASTEC code to CANDU NPP severe accident analysis two kinds of activities were performed: - analyses of the ASTEC modules from the point of view of models and options, followed by CANDU exploratory calculation for the appropriate modules/models; - preparing the specifications for ASTEC adaptation for CANDU NPP. The paper is structured in three parts: - a comparison of PWR and CANDU concepts (from the point of view of severe accident phenomena); - exploratory calculations with some ASTEC modules- SOPHAEROS, CPA, IODE, CESAR, DIVA - for CANDU type reactors specific problems; - development needs analysis - algorithms, methods, modules. (authors)

  4. CANDU pressure tube leak detection by annulus gas dew point measurement. A critical review

    International Nuclear Information System (INIS)

    Greening, F.R.

    2017-01-01

    In the event of a pressure tube leak from a small through-wall crack during CANDU reactor operations, there is a regulatory requirement - referred to as Leak Before Break (LBB) - for the licensee to demonstrate that there will be sufficient time for the leak to be detected and the reactor shut down before the crack grows to the critical size for fast-uncontrolled rupture. In all currently operating CANDU reactors, worldwide, this LBB requirement is met via continuous dew point measurements of the CO_2 gas circulating in the reactor's Annulus Gas System (AGS). In this paper the historical development and current status of this leak detection capability is reviewed and the use of moisture injection tests as a verification procedure is critiqued. It is concluded that these tests do not represent AGS conditions that are to be expected in the event of a real pressure tube leak.

  5. CANDU pressure tube leak detection by annulus gas dew point measurement. A critical review

    Energy Technology Data Exchange (ETDEWEB)

    Greening, F.R. [CTS-NA, Tiverton, ON (Canada)

    2017-03-15

    In the event of a pressure tube leak from a small through-wall crack during CANDU reactor operations, there is a regulatory requirement - referred to as Leak Before Break (LBB) - for the licensee to demonstrate that there will be sufficient time for the leak to be detected and the reactor shut down before the crack grows to the critical size for fast-uncontrolled rupture. In all currently operating CANDU reactors, worldwide, this LBB requirement is met via continuous dew point measurements of the CO{sub 2} gas circulating in the reactor's Annulus Gas System (AGS). In this paper the historical development and current status of this leak detection capability is reviewed and the use of moisture injection tests as a verification procedure is critiqued. It is concluded that these tests do not represent AGS conditions that are to be expected in the event of a real pressure tube leak.

  6. THE IMPACT OF POWER COEFFICIENT OF REACTIVITY ON CANDU 6 REACTORS

    Directory of Open Access Journals (Sweden)

    D. KASTANYA

    2013-10-01

    Full Text Available The combined effects of reactivity coefficients, along with other core nuclear characteristics, determine reactor core behavior in normal operation and accident conditions. The Power Coefficient of Reactivity (PCR is an aggregate indicator representing the change in reactor core reactivity per unit change in reactor power. It is an integral quantity which captures the contributions of the fuel temperature, coolant void, and coolant temperature reactivity feedbacks. All nuclear reactor designs provide a balance between their inherent nuclear characteristics and the engineered reactivity control features, to ensure that changes in reactivity under all operating conditions are maintained within a safe range. The CANDU® reactor design takes advantage of its inherent nuclear characteristics, namely a small magnitude of reactivity coefficients, minimal excess reactivity, and very long prompt neutron lifetime, to mitigate the demand on the engineered systems for controlling reactivity and responding to accidents. In particular, CANDU reactors have always taken advantage of the small value of the PCR associated with their design characteristics, such that the overall design and safety characteristics of the reactor are not sensitive to the value of the PCR. For other reactor design concepts a PCR which is both large and negative is an important aspect in the design of their engineered systems for controlling reactivity. It will be demonstrated that during Loss of Regulation Control (LORC and Large Break Loss of Coolant Accident (LBLOCA events, the impact of variations in power coefficient, including a hypothesized larger than estimated PCR, has no safety-significance for CANDU reactor design. Since the CANDU 6 PCR is small, variations in the range of values for PCR on the performance or safety of the reactor are not significant.

  7. The analysis in real time, during the pre-commissioning period, of the overall plant control system of the CANDU NPP unit

    International Nuclear Information System (INIS)

    Tapu, C.; Irimia, M.

    1994-01-01

    The physical processes in the CANDU NPP are controlled by a computer system which, based on the associated package of programmes, performs both the monitoring function at the level of the operational area, and the digital regulation function of the technological systems within the NPP. For an optimal operation of the NPP, in dynamic as well as in stationary regime, the correlation of the direct digital control of the technological systems is very important for the NPP's overall digital control system. Taking into account the fact that during the pre-commissioning period of a CANDU unit it is necessary to test in dynamic regime the performance of the overall digital control function of the NPP, a system of verification and testing in real time was developed, by connecting a micro simulator of the physical process in the NPP to the actual computer system of the unit. The paper presents the methods and techniques used, as well as the results of the tests for various operational modes, which highlight the functioning of the digital control system of the CANDU NPP unit. (Author)

  8. CANDU physics considerations for the disposition of weapons-grade plutonium

    Energy Technology Data Exchange (ETDEWEB)

    Pitre, J; Chan, P; Dastur, A [Atomic Energy of Canada Ltd., Mississauga, ON (Canada)

    1996-12-31

    At the request of the US Department of Energy AECL has examined the feasibility of using CANDU for the disposition of weapons grade plutonium. Utilizing existing CANDU technology, the feasibility of using MOX (mixed oxide) fuel in an existing CANDU reactor was studied. The results of this study indicate that the target disposition for disposal of weapons grade plutonium can be met without the requirement of any major modifications to existing plant design. (author). 3 refs., 4 tabs., 5 figs.

  9. CANDU physics considerations for the disposition of weapons-grade plutonium

    International Nuclear Information System (INIS)

    Pitre, J.; Chan, P.; Dastur, A.

    1995-01-01

    At the request of the US Department of Energy AECL has examined the feasibility of using CANDU for the disposition of weapons grade plutonium. Utilizing existing CANDU technology, the feasibility of using MOX (mixed oxide) fuel in an existing CANDU reactor was studied. The results of this study indicate that the target disposition for disposal of weapons grade plutonium can be met without the requirement of any major modifications to existing plant design. (author). 3 refs., 4 tabs., 5 figs

  10. Evolution of CANDU vacuum building and pressure relief structures from Pickering NGS A to Darlington NGS A

    International Nuclear Information System (INIS)

    Beg, Z.M.; Ghosh, R.S.

    1987-01-01

    The vacuum building (VB) and pressure relief structures (PRS) are the unique features of multiple unit CANDU containments. In case of loss-of-coolant accident, the released radionuclides are drawn through the PRS into the subatmospheric VB, doused and contained without being released to the environment. This paper describes the differences in design, configuration and layout of the VB and PRS from Pickering NGS A to Darlington NGS A due to new developments in design concepts and to requirements which have proceeded from the experience gained in both the design and operation of the nuclear stations. (orig.)

  11. An approach to neutronics analysis of candu reactors

    International Nuclear Information System (INIS)

    Gul, S.; Arshad, M.

    1982-12-01

    An attempt is made to tackle the problem of neutronics analysis of CANDU reactors. Until now CANDU reactors have been analysed by the methods developed at AECL and CGE using mainly receipe methods. Relying on multigroup transport codes GAM-GATHER in combination with diffusion code CITATION a package of codes is established to use it for survey as well as production purposes. (authors)

  12. Assessment of CANDU-6 reactivity devices for DUPIC fuel

    International Nuclear Information System (INIS)

    Jeong, Chang Joon; Choi, Hang Bok

    1998-11-01

    Reactivity device characteristics for a CANDU 6 reactor loaded with DUPIC fuel have been assessed. The lattice parameters were generated by WIMS-AECL code and the core calculations were performed by RFSP code with a 3-dimensional full core model. The reactivity devices studied are the zone controller, adjusters, mechanical control absorber and shutoff rods. For the zone controller system, damping capability for spatial oscillation was investigated. For the adjusters, the restart capability was investigated. For the adjusters, the restart capability was investigated. The shin operation and power stepback calculation were also performed to confirm the compatibility of the current adjuster system. The mechanical control absorber was assessed for the function of compensating temperature reactivity feedback following a power reduction. And shutoff rods were also assessed to investigate the following a power reduction. And shutoff rods were also assessed to investigate the static reactivity worth. This study has shown that the current reactivity device system of CANDU-6 core with the DUPIC fuel. (author). 9 refs., 17 tabs., 7 figs

  13. Development of the CANDU 66-group SN transport library

    International Nuclear Information System (INIS)

    Tsang, K.T.

    2001-01-01

    The design of the shield configuration around a nuclear reactor is strongly dependent on the neutron and photon spatial and energy distributions. The nuclear heat deposition and material damage in and surrounding the reactor core are also a function of the neutron and photon distributions. Therefore, to ensure a suitable configuration of materials for shielding or heat transfer, an accurate calculation of the particle fluxes in the reactor systems is essential. The CANDU 66-group library was developed to update the cross sections that are needed to assess the performance of CANDU bulk shields. Since about 1980, shielding analysts at Atomic Energy of Canada Limited (AECL) and Ontario Power Generation Inc. (OPGI) have been using a 38-group CANDU-specific library to perform S N transport calculations. In 1994, a new CANDU 67-group cross-section library was developed. The 67-group cross-section library was developed to provide radiation-physics analysts with up-to-date nuclear data to correct deficiencies with documentation of the old library. Although there were improvements over the 38-group library, initial use showed there were some deficiencies in the 67-group library. To correct these deficiencies, the CANDU 66-group S N transport cross-section library was developed. The 66-group library is based on the 241-group cross-section library VITAMIN-B6. Collapsing and weighting of the 241-group cross sections into 66 groups were performed using the modular code system SCALE 4.4. This paper describes how the modules in the SCALE system were applied to generate the 66-group library. The CANDU 66-group library includes both core-weighted and lattice-weighted cross sections of 235 U, 238 U, and 239 Pu with, and without, delayed fission-product photons. In addition, the 66-group library contains more response functions than did the 67-group library. Finally, the CANDU 66-group library has been validated against one-dimensional benchmark problems. The results generated with

  14. Development of CANDU prototype fuel handling simulator - concept and some simulation results with physical network modeling approach

    Energy Technology Data Exchange (ETDEWEB)

    Xu, X.P. [Candu Energy Inc, Mississauga, Ontario (Canada)

    2012-07-01

    This paper reviewed the need for a fuel handling(FH) simulator in training operators and maintenance personnel, in FH design enhancement based on operating experience (OPEX), and the potential application of Virtual Reality (VR) based simulation technology. Modeling and simulation of the fuelling machine (FM) magazine drive plant (one of the CANDU FH sub-systems) was described. The work established the feasibility of modeling and simulating a physical FH drive system using the physical network approach and computer software tools. The concept and approach can be applied similarly to create the other FH subsystem plant models, which are expected to be integrated with control modules to develop a master FH control model and further to create a virtual FH system. (author)

  15. Development of CANDU prototype fuel handling simulator - concept and some simulation results with physical network modeling approach

    International Nuclear Information System (INIS)

    Xu, X.P.

    2012-01-01

    This paper reviewed the need for a fuel handling(FH) simulator in training operators and maintenance personnel, in FH design enhancement based on operating experience (OPEX), and the potential application of Virtual Reality (VR) based simulation technology. Modeling and simulation of the fuelling machine (FM) magazine drive plant (one of the CANDU FH sub-systems) was described. The work established the feasibility of modeling and simulating a physical FH drive system using the physical network approach and computer software tools. The concept and approach can be applied similarly to create the other FH subsystem plant models, which are expected to be integrated with control modules to develop a master FH control model and further to create a virtual FH system. (author)

  16. Assessment of CHF characteristics at subcooled conditions for the CANDU CANFLEX bundle

    International Nuclear Information System (INIS)

    Onder, E.N.; Leung, L.K.H.

    2011-01-01

    An analysis has been performed to assess the Critical Heat Flux (CHF) characteristics for the CANFLEX bundle at subcooled conditions. CHF characteristics for CANDU bundles have been established from experiments using full-scale bundle simulators. These experiments covered flow conditions of interest to normal operation and postulated loss-of-flow and small break loss-of-coolant accidents. Experimental CHF values obtained from these experiments were applied to develop correlations for analyses of regional overpower protection and safety trips. These correlations are applicable to the saturated region in the reference uncrept channel and the slightly subcooled region in postulated high-creep channels. Expanding the CHF data to subcooled conditions facilitates the evaluation of the margin to dryout at upstream bundle locations, even though dryout occurrences are not anticipated there. In view of the lack of experimental data, the ASSERT-PV subchannel code has been applied to establish CHF values at low qualities and high subcoolings (thermodynamic qualities corresponding to -25%). These CHF values have been applied to extend the CHF correlation to the highly subcooled conditions. (author)

  17. Fuel channel design improvements for large CANDU reactors

    Energy Technology Data Exchange (ETDEWEB)

    Villamagna, A; Price, E G; Field, G J [Atomic Energy of Canada Ltd., Mississauga, ON (Canada)

    1996-12-31

    From the initial designs used in NPD and Douglas point reactors, the CANDU fuel channel and its components have undergone considerable development. Two major designs have evolved: the Pickering/CANDU 6 design which has 12 fuel bundles in the core and where the new fuel is inserted into the inlet end, and the Bruce/Darlington design which has 13 bundles in the channel and where new fuel is inserted into the outlet end. In the development of a single unit CANDU reactor of the size of a Bruce or Darlington unit which would use a Darlington design calandria, the decision has been made to use the CANDU 6 fuel channel rather than the Darlington design. The CANDU 6 channel has provided excellent performance and will not encounter the degree of maintenance required for the Bruce/Darlington design. The channel design in turn influences the fuelling machine/fuel handling concepts required. The changes to the CANDU 6 fuel channel design to incorporate it in the large unit are small. In fact, the changes that are proposed relate to the desire to increase margins between pressure tube properties and design conditions or ameliorate the consequences of postulated accident conditions, rather than necessary adaptation to the larger unit. Better properties have been achieved in the pressure tube material resulting from alloy development program over the past 10 years. Pressure tubes can now he made with very low hydrogen concentrations so that the hydrogen picked up as deuterium will not exceed the terminal solid solubility for the in-core region in 30 years. The improvements in metal chemistry allow the production of high toughness tubes that retain a high level of toughness during service. A small increase in wall thickness will reduce the dimensional changes without significantly affecting burnup. Changes to increase safety margins from postulated accidents are concentrated on containing the consequences of pressure tube damage. The changes are concentrated on the calandria tube

  18. Optimal Refueling Pattern Search for a CANDU Reactor Using a Genetic Algorithm

    International Nuclear Information System (INIS)

    Quang Binh, DO; Gyuhong, ROH; Hangbok, CHOI

    2006-01-01

    This paper presents the results from the application of genetic algorithms to a refueling optimization of a Canada deuterium uranium (CANDU) reactor. This work aims at making a mathematical model of the refueling optimization problem including the objective function and constraints and developing a method based on genetic algorithms to solve the problem. The model of the optimization problem and the proposed method comply with the key features of the refueling strategy of the CANDU reactor which adopts an on-power refueling operation. In this study, a genetic algorithm combined with an elitism strategy was used to automatically search for the refueling patterns. The objective of the optimization was to maximize the discharge burn-up of the refueling bundles, minimize the maximum channel power, or minimize the maximum change in the zone controller unit (ZCU) water levels. A combination of these objectives was also investigated. The constraints include the discharge burn-up, maximum channel power, maximum bundle power, channel power peaking factor and the ZCU water level. A refueling pattern that represents the refueling rate and channels was coded by a one-dimensional binary chromosome, which is a string of binary numbers 0 and 1. A computer program was developed in FORTRAN 90 running on an HP 9000 workstation to conduct the search for the optimal refueling patterns for a CANDU reactor at the equilibrium state. The results showed that it was possible to apply genetic algorithms to automatically search for the refueling channels of the CANDU reactor. The optimal refueling patterns were compared with the solutions obtained from the AUTOREFUEL program and the results were consistent with each other. (authors)

  19. Survey of considerations involved in introducing CANDU reactors into the United States

    International Nuclear Information System (INIS)

    Till, C.E.; Bohn, E.M.; Chang, Y.I.; van Erp, J.B.

    1977-01-01

    The important issues that must be considered in a decision to utilize CANDU reactors in the U.S. are identified in this report. Economic considerations, including both power costs and fuel utilization, are discussed for the near and longer term. Safety and licensing considerations are reviewed for CANDU-PHW reactors in general. The important issues, now and in the future, associated with power generation costs are the capital costs of CANDUs and the factors that impact capital cost comparisons. Fuel utilization advantages for the CANDU depend upon assumptions regarding fuel recycle at present, but the primary issue in the longer term is the utilization of the thorium cycle in the CANDU. Certain safety features of the CANDU are identified as intrinsic to the concept and these features must be examined more fully regarding licensability in the U.S

  20. Development of the advanced CANDU technology

    International Nuclear Information System (INIS)

    Suk, Soo Dong; Min, Byung Joo; Na, Y. H.; Lee, S. Y.; Choi, J. H.; Lee, B. C.; Kim, S. N.; Jo, C. H.; Paik, J. S.; On, M. R.; Park, H. S.; Kim, S. R.

    1997-07-01

    The purpose of this study is to develop the advanced design technology to improve safety, operability and economy and to develop and advanced safety evaluation system. More realistic and reasonable methodology and modeling was employed to improve safety margin in containment analysis. Various efforts have been made to verify the CATHENA code which is the major safety analysis code for CANDU PHWR system. Fully computerized prototype ECCS was developed. The feasibility study and conceptual design of the distributed digital control system have been performed as well. The core characteristics of advanced fuel cycle, fuel management and power upgrade have been studied to determine the advanced core. (author). 77 refs., 51 tabs., 108 figs

  1. Development of the advanced CANDU technology

    Energy Technology Data Exchange (ETDEWEB)

    Suk, Soo Dong; Min, Byung Joo [Korea Atomic Energy Research Institute, Taejon (Korea, Republic of); Na, Y H; Lee, S Y; Choi, J H; Lee, B C; Kim, S N; Jo, C H; Paik, J S; On, M R; Park, H S; Kim, S R [Korea Electric Power Co., Taejon (Korea, Republic of)

    1997-07-01

    The purpose of this study is to develop the advanced design technology to improve safety, operability and economy and to develop and advanced safety evaluation system. More realistic and reasonable methodology and modeling was employed to improve safety margin in containment analysis. Various efforts have been made to verify the CATHENA code which is the major safety analysis code for CANDU PHWR system. Fully computerized prototype ECCS was developed. The feasibility study and conceptual design of the distributed digital control system have been performed as well. The core characteristics of advanced fuel cycle, fuel management and power upgrade have been studied to determine the advanced core. (author). 77 refs., 51 tabs., 108 figs.

  2. Future CANDU nuclear power plant design requirements document executive summary

    International Nuclear Information System (INIS)

    Lee, Duk Su; Chang, Woo Hyun; Lee, Nam Young; S. A. Usmani

    1996-03-01

    The future CANDU Requirements Document (FCRED) describes a clear and complete statement of utility requirements for the next generation of CANDU nuclear power plants including those in Korea. The requirements are based on proven technology of PHWR experience and are intended to be consistent with those specified in the current international requirement documents. Furthermore, these integrated set of design requirements, incorporate utility input to the extent currently available and assure a simple, robust and more forgiving design that enhances the performance and safety. The FCRED addresses the entire plant, including the nuclear steam supply system and the balance of the plant, up to the interface with the utility grid at the distribution side of the circuit breakers which connect the switchyard to the transmission lines. Requirements for processing of low level radioactive waste at the plant site and spent fuel storage requirements are included in the FCRED. Off-site waste disposal is beyond the scope of the FCRED. 2 tabs., 1 fig. (Author) .new

  3. Diversified emergency core cooling in CANDU with a passive moderator heat rejection system

    Energy Technology Data Exchange (ETDEWEB)

    Spinks, N [AECL Research, Chalk River Labs., Chalk River, ON (Canada)

    1996-12-01

    A passive moderator heat rejection system is being developed for CANDU reactors which, combined with a conventional emergency-coolant injection system, provides the diversity to reduce core-melt frequency to order 10{sup -7} per unit-year. This is similar to the approach used in the design of contemporary CANDU shutdown systems which leads to a frequency of order 10{sup -8} per unit-year for events leading to loss of shutdown. Testing of a full height 1/60 power-and-volume-scaled loop has demonstrated the feasibility of the passive system for removal of moderator heat during normal operation and during accidents. With the frequency of core-melt reduced, by these measures, to order 10{sup -7} per unit year, no need should exist for further mitigation. (author). 3 refs, 2 figs.

  4. Assessment and management of ageing of major nuclear power plant components important to safety: CANDU reactor assemblies

    International Nuclear Information System (INIS)

    2001-02-01

    At present, there are over four hundred operational nuclear power plants (NPPs) in IAEA Member States. Operating experience has shown that ineffective control of the ageing degradation of the major NPP components (e.g. caused by unanticipated phenomena and by operating, maintenance, design or manufacturing errors) can jeopardize plant safety and also plant life. Ageing in these NPPs must therefore be effectively managed to ensure the availability of design functions throughout the plant service life. From the safety perspective, this means controlling within acceptable limits the ageing degradation and wearout of plant components important to safety so that adequate safety margins remain, i.e. integrity and functional capability in excess of normal operating requirements. This TECDOC is one in a series of reports on the assessment and management of ageing of the major NPP components important to safety. The reports are based on experience and practices of NPP operators, regulators, designers, manufacturers, and technical support organizations and a widely accepted Methodology for the Management of Ageing of NPP Components Important to Safety which was issued by the IAEA in 1992. The current practices for the assessment of safety margins (fitness for service) and the inspection, monitoring, and mitigation of ageing degradation of selected components of Canada deuterium-uranium (CANDU) reactors, boiling water reactors (BWRs), pressurized water reactors (PWRs) including the Soviet designed water moderated and water cooled energy reactors (WWERs), are documented in the reports. These practices are intended to help all involved directly and indirectly in ensuring the safe operation of NPPs and also to provide a common technical basis for dialogue between plant operators and regulators when dealing with age-related licensing issues. Since the reports are written from a safety perspective, they do not address life or life-cycle management of the plant components, which

  5. FSN-based fault modelling for fault detection and troubleshooting in CANDU stations

    Energy Technology Data Exchange (ETDEWEB)

    Nasimi, E., E-mail: elnara.nasimi@brucepower.com [Bruce Power LLP., Tiverton, Ontario(Canada); Gabbar, H.A. [Univ. of Ontario Inst. of Tech., Oshawa, Ontario (Canada)

    2013-07-01

    An accurate fault modeling and troubleshooting methodology is required to aid in making risk-informed decisions related to design and operational activities of current and future generation of CANDU designs. This paper presents fault modeling approach using Fault Semantic Network (FSN) methodology with risk estimation. Its application is demonstrated using a case study of Bruce B zone-control level oscillations. (author)

  6. Development of best estimate auditing code for CANDU thermal hydraulic safety analysis

    Energy Technology Data Exchange (ETDEWEB)

    Chung, B. D.; Lee, W. J.; Lim, H. S. [Korea Atomic Energy Research Institute, Taejon (Korea, Republic of)

    2000-03-15

    The main purpose of this study is to develop a thermal hydraulic auditing code for the CANDU reactor, modifying the model if existing PWR auditing tool, i.e. RELAP5/MOD3. This scope of project is a third step of the whole project, and expand the RELAP5/MOD3/CANDU version for implementation of LOCA analysis. There are three main area of model development, i.e. moody critical flow model, flow regime model of horizontal CANDU bundle, and fuel element heatup model when the stratification occurs. Newly developed version, namely RELAP5/MOD3/CANDU+ is applicable to CANDU plant analysis with keeping the function of light water reactor analysis. The limited validations of model installation were performed. Assessment of CHF model using AECL separated effect test and calculation for Wolsong 2 plant were performed also for the applicability test of the developed version.

  7. CANDU reactor core simulations using fully coupled DRAGON and DONJON calculations

    International Nuclear Information System (INIS)

    Varin, E.; Marleau, G.

    2006-01-01

    The operating CANDU-6 reactors are refueled on-power to compensate for the reactivity loss due to fuel burnup. In order to predict the core behavior, fuel bundle burnups and local parameter information need to be tracked. The history-based approach has been developed to follow local parameter as well as history effect in CANDU reactors. The finite reactor diffusion code DONJON and the lattice code DRAGON have been coupled to perform reactor follow-up calculations using a history-based approach. A coupled methodology that manages the transfer of information between standard DONJON and DRAGON data structures has been developed. Push-through refueling can be taken into account directly in cell calculations. Using actual on-site information, an isotopic core content database has been generated with coupled DONJON and DRAGON calculations. Moreover calculations have been performed for different local parameters. Results are compared with those obtained using standard cross section generation approaches

  8. A Model to Reproduce the Response of the Gaseous Fission Product Monitor (GFPM) in a CANDU{sup R} 6 Reactor (An Estimate of Tramp Uranium Mass in a Candu Core)

    Energy Technology Data Exchange (ETDEWEB)

    Mostofian, Sara; Boss, Charles [AECL Atomic Energy of Canada Limited, 2251 Speakman Drive, Mississauga Ontario L5K 1B2 (Canada)

    2008-07-01

    In a Canada Deuterium Uranium (Candu) reactor, the fuel bundles produce gaseous and volatile fission products that are contained within the fuel matrix and the welded zircaloy sheath. Sometimes a fuel sheath can develop a defect and release the fission products into the circulating coolant. To detect fuel defects, a Gaseous Fission Product Monitoring (GFPM) system is provided in Candu reactors. The (GFPM) is a gamma ray spectrometer that measures fission products in the coolant and alerts the operator to the presence of defected fuel through an increase in measured fission product concentration. A background fission product concentration in the coolant also arises from tramp uranium. The sources of the tramp uranium are small quantities of uranium contamination on the surfaces of fuel bundles and traces of uranium on the pressure tubes, arising from the rare defected fuel element that released uranium into the core. This paper presents a dynamic model that reproduces the behaviour of a GFPM in a Candu 6 plant. The model predicts the fission product concentrations in the coolant from the chronic concentration of tramp uranium on the inner surface of the pressure tubes (PT) and the surface of the fuel bundles (FB) taking into account the on-power refuelling system. (authors)

  9. CANDU-6 fuel optimization for advanced cycles

    Energy Technology Data Exchange (ETDEWEB)

    St-Aubin, Emmanuel, E-mail: emmanuel.st-aubin@polymtl.ca; Marleau, Guy, E-mail: guy.marleau@polymtl.ca

    2015-11-15

    Highlights: • New fuel selection process proposed for advanced CANDU cycles. • Full core time-average CANDU modeling with independent refueling and burnup zones. • New time-average fuel optimization method used for discrete on-power refueling. • Performance metrics evaluated for thorium-uranium and thorium-DUPIC cycles. - Abstract: We implement a selection process based on DRAGON and DONJON simulations to identify interesting thorium fuel cycles driven by low-enriched uranium or DUPIC dioxide fuels for CANDU-6 reactors. We also develop a fuel management optimization method based on the physics of discrete on-power refueling and the time-average approach to maximize the economical advantages of the candidates that have been pre-selected using a corrected infinite lattice model. Credible instantaneous states are also defined using a channel age model and simulated to quantify the hot spots amplitude and the departure from criticality with fixed reactivity devices. For the most promising fuels identified using coarse models, optimized 2D cell and 3D reactivity device supercell DRAGON models are then used to generate accurate reactor databases at low computational cost. The application of the selection process to different cycles demonstrates the efficiency of our procedure in identifying the most interesting fuel compositions and refueling options for a CANDU reactor. The results show that using our optimization method one can obtain fuels that achieve a high average exit burnup while respecting the reference cycle safety limits.

  10. Review of the Safety Concern Related to CANDU Moderator Temperature Distribution and Status of KAERI Moderator Circulation Test (MCT) Experiments

    Energy Technology Data Exchange (ETDEWEB)

    Rhee, Bo W.; Kim, Hyoung T. [Severe Accident and PHWR Safety Research Division, Daejeon (Korea, Republic of); Kim, Tongbeum [University of the Witwatersrand, Johannesburg (South Africa); Im, Sunghyuk [KAIST, Daejeon (Korea, Republic of)

    2015-10-15

    threshold temperature and no further deformation is expected. Consequently, a sufficient condition to ensure fuel channel integrity following a large LOCA, is the avoidance of sustained calandria tubes dryout. If the moderator available subcooling at the onset of a large LOCA is greater than the subcooling requirements, a sustained calandria tube dryout is avoided. The temperature oscillations observed in reactor and in test measurements such as MTF need to be characterized and quantified to show that it does not jeopardize the currently available safety margins. Because of the importance of an accurate prediction of moderator temperature distributions and the related moderator subcooling, a 1/4 scaled-down moderator tank of a CANDU-6 reactor, called Moderator Circulation Test (MCT), was erected at KAERI and the current status of MCT experiment progress is described and further experiments are expected to be carried out to generate the experimental data necessary to validate the computer codes that will be used to analyze the accident analysis of operating CANDU-6 plants.

  11. Molybdenum-99-producing 37-element fuel bundle neutronically and thermal-hydraulically equivalent to a standard CANDU fuel bundle

    Energy Technology Data Exchange (ETDEWEB)

    Nichita, E., E-mail: Eleodor.Nichita@uoit.ca; Haroon, J., E-mail: Jawad.Haroon@uoit.ca

    2016-10-15

    Highlights: • A 37-element fuel bundle modified for {sup 99}Mo production in CANDU reactors is presented. • The modified bundle is neutronically and thermal-hydraulically equivalent to the standard bundle. • The modified bundle satisfies all safety criteria satisfied by the standard bundle. - Abstract: {sup 99m}Tc, the most commonly used radioisotope in diagnostic nuclear medicine, results from the radioactive decay of {sup 99}Mo which is currently being produced at various research reactors around the globe. In this study, the potential use of CANDU power reactors for the production of {sup 99}Mo is investigated. A modified 37-element fuel bundle, suitable for the production of {sup 99}Mo in existing CANDU-type reactors is proposed. The new bundle is specifically designed to be neutronically and thermal-hydraulically equivalent to the standard 37-element CANDU fuel bundle in normal, steady-state operation and, at the same time, be able to produce significant quantities of {sup 99}Mo when irradiated in a CANDU reactor. The proposed bundle design uses fuel pins consisting of a depleted-uranium centre surrounded by a thin layer of low-enriched uranium. The new molybdenum-producing bundle is analyzed using the lattice transport code DRAGON and the diffusion code DONJON. The proposed design is shown to produce 4081 six-day Curies of {sup 99}Mo activity per bundle when irradiated in the peak-power channel of a CANDU core, while maintaining the necessary reactivity and power rating limits. The calculated {sup 99}Mo yield corresponds to approximately one third of the world weekly demand. A production rate of ∼3 bundles per week can meet the global demand of {sup 99}Mo.

  12. Neutronic parameters calculations of a CANDU reactor

    International Nuclear Information System (INIS)

    Zamonsky, G.

    1991-01-01

    Neutronic calculations that reproduce in a simplified way some aspects of a CANDU reactor design were performed. Starting from some prefixed reactor parameters, cylindrical and uniform iron adjuster rods were designed. An appropriate refueling scheme was established, defininig in a 2 zones model their dimensions and exit burnups. The calculations have been done using the codes WIMS-D4 (cell), SNOD (reactivity device simulations) and PUMA (reactor). Comparing with similar calculations done with codes and models usually employed for CANDU design, it is concluded that the models and methods used are appropriate. (Author) [es

  13. Quality control of CANDU6 fuel element in fabrication process

    International Nuclear Information System (INIS)

    Li Yinxie; Zhang Jie

    2012-01-01

    To enhance the fine control over all aspects of the production process, improve product quality, fuel element fabrication process for CANDU6 quality process control activities carried out by professional technical and management technology combined mode, the quality of the fuel elements formed around CANDU6 weak links - - end plug , and brazing processes and procedures associated with this aspect of strict control, in improving staff quality consciousness, strengthening equipment maintenance, improved tooling, fixtures, optimization process test, strengthen supervision, fine inspection operations, timely delivery carry out aspects of the quality of information and concerns the production environment, etc., to find the problem from the improvement of product quality and factors affecting the source, and resolved to form the active control, comprehensive and systematic analysis of the problem of the quality management concepts, effectively reducing the end plug weld microstructure after the failure times and number of defects zirconium alloys brazed, improved product quality, and created economic benefits expressly provided, while staff quality consciousness and attention to detail, collaboration department, communication has been greatly improved and achieved very good management effectiveness. (authors)

  14. Fuel-management simulations for once-through thorium fuel cycle in CANDU reactors

    International Nuclear Information System (INIS)

    Chan, P.S.W.; Boczar, P.G.; Ellis, R.J.; Ardeshiri, F.

    1999-01-01

    High neutron economy, on-power refuelling and a simple fuel bundle design result in unsurpassed fuel cycle flexibility for CANDU reactors. These features facilitate the introduction and exploitation of thorium fuel cycles in existing CANDU reactors in an evolutionary fashion. Detailed full-core fuel-management simulations concluded that a once-through thorium fuel cycle can be successfully implemented in an existing CANDU reactor without requiring major modifications. (author)

  15. On the feasibility of a CANDU PHWR actinide burner

    International Nuclear Information System (INIS)

    Anton, V.

    1995-01-01

    In this work a review of the current solutions to burn the actinide i.e. the spallation method, LWR, FBR, Siemens proposal and inert matrix is presented. Finally, a proposal is made to use the CANDU PHWR for this purpose, taking into account the techniques envisaged for LWR and the prospect of the advanced fuel cycle in CANDU system. (Author) 5 Refs

  16. Towards more efficient safeguards approach of transfer campaign in Wolsong CANDU reactor

    International Nuclear Information System (INIS)

    Park, S. K.; Na, W. W.; Park, W. S.; Jung, S. T.; Park, S. J.

    2002-01-01

    Due to the unique character of the CANDU reactor, a transfer campaign has been carried out every year for 2 months or so in Wolsong unit 1. It is expected to require performance of the transfer campaign for 4 units of Wolsong site in 2006 and more than 50% of the ROK safeguards inspection efforts. The IAEA and TCNC have gained several years of experience in safeguards approach during transfer campaign. Occasionally the deterrence and interference of operator transfer work have been occurred in order to attain safeguards inspection goal. These could be minimized using optimum C/S applications, NDA and RDT techniques. This paper shows the interrelationship and combinations of these resources and proposes new safeguards approach to maintain the continuity of knowledge from fuel loading in the spent fuel pond to the point of canister loading and closure during transfer campaign

  17. Experimental and thermodynamic assessment of beryllium-replacement materials for CANDU brazed joints

    Energy Technology Data Exchange (ETDEWEB)

    Potter, K.N.; Ferrier, G.A.; Corcoran, E.C., E-mail: Kieran.Potter@rmc.ca [Royal Military College of Canada, Kingston ON, (Canada); Dimayuga, F.C. [Canadian Nuclear Laboratories, Chalk River, ON (Canada)

    2015-07-01

    Currently, appendages are joined to CANDU fuel elements via a brazing process, with beryllium as the filler material. A potential reduction in the occupational limit on airborne beryllium particulates has motivated research into alternative brazing materials. To this end, the Canadian nuclear industry has funded an initiative to identify and evaluate the suitability of several candidate brazing materials. This work describes contributions toward the assessment of alternative brazing materials from the Royal Military College of Canada (RMCC). An impact testing method was developed to evaluate the mechanical strength of candidate braze joints.Thermodynamic modelling was performed to predict the aqueous behaviour of each candidate material in CANDU coolant conditions characteristic of reactor shutdown, and corrosion experiments are underway to support modelling predictions.The results of these activities will assist in selecting a suitable replacement material for beryllium. (author)

  18. Current activities in support of CANDU plant life management: an industry perspective

    International Nuclear Information System (INIS)

    Shalaby, B.A.; Price, E.G.; Hopkins, J.; Charlebois, P.

    1998-01-01

    The current focus of the CANDU industry is to position the nuclear option as a cost competitive, safe and reliable means of electricity production. To achieve its goal the CANDU industry as a whole is undertaking steps to improve further its performance and safety of its nuclear power plants. A number of programs have been planned and implemented particularly for plants in the mid-life range. Some of these programs include life assessment studies of critical systems, Structures and Components (SSCS), refurbishment and upgrading programs and monitoring and periodic inspection programs. Some elements of the programs have been in place from station start up and some are being instituted as part of the aging management and performance improvement program. The industry recognizes that the key to sustaining high performance over the life of the plant is the implementation of an integrated aging management program that encompasses all elements of plant operation and maintenance. A systematically implemented program on optimized maintenance and inspection strategy, standardized work processes, component rehabilitation programs, and applying lessons learned are some of the elements of a sustainable high performance and an effective plant life assurance program. The paper will describe the elements of an integrated program, the multiphase approach defined for CANDU PLIM and some of the activities undertaken by the industry to further improve and sustain plant safety, reliability and performance. (author)

  19. A study on framework for assessing limiting condition for operation(LCOs) quantitatively in a CANDU reactor

    International Nuclear Information System (INIS)

    Kang, Kyung Min

    2003-02-01

    Limiting conditions for operations define the allowed outage times and the actions to be taken if the repair cannot be completed within the AOT. Typically the actions required are plant shutdown. In situations where the risk associated with the action, i.e., the risk of plant shutdown given a failure in the safety system, may be substantial, a strategy is needed to control the risk implications. In this study the strategy is evaluated quantitatively using a tool of system dynamics. The strategic actions associated with LCO needs to be assessed dynamically. System dynamics technique is easy enough to be applied for quantitative assessment of LCO, where the system dynamics is an important factor in evaluating operational modes of nuclear power plants. The review on the improvements of overly conservative technical specification has been performed in this study. The VENSIM tool has been applied to evaluate quantitatively the LCO of the auxiliary feed water systems in the Wol-Sung nuclear power plant. A value of core damage frequency in PSA is used as risk measure. The analysis of both full power operation and shutdown operation has been compared for the value of the CDF. This study shows a plot of LCO full power operating and shutdown risks in term of core damage probability for failure of AFWS (auxiliary feedwater system). Obtaining a lower risk level in a stable mode, compared to the LCO operation alternative, is the principal motivation of going to full power operational mode or shutdown operational mode. A time dependent framework developed in this study has been applied to assess the LCO of the example problem and it is shown that it is very flexible in that it can be applied to assess LCO quantitatively under any operational context of the technical specifications. This study contributes risk informed regulation to enhance and optimize the LCO of previous technical specifications for CANDU through developing framework in application proposed in this methodology

  20. Design capability of CANDU heat transport pump shafts against cracking

    International Nuclear Information System (INIS)

    Kumar, A.N.; Sheikh, Z.B.; Padgett, A.

    1993-01-01

    During 1986 three different Light Water Reactors (LWR's) in the U.S. reported either a cracked or fractured shaft on one or more of their reactor coolant (RC) pumps. The RC pumps for all these stations were supplied by Byron Jackson (BJ) Pump Company. A majority of CANDU heat transport (HT) pumps (equivalent of RC pumps) are supplied by BJ Pump Company and are similar in design to RC pumps. Hence the failure of these RC pumps in the U.S. utilities caused concern regarding the relevance of these failures to the BJ supplied CANDU HT pumps (HTP). This paper presents the results of AECL assessment to establish the capability of the HT pump shaft against cracking. Two methods were used for assessment: (a) detailed comparative design review of the HTP and RCP shafts; (b) semi-empirical analysis of the HTP shafts. The results of the AECL assessment showed significant differences in detailed design, materials, assembly and fits of various components and the control of operating parameters between the HT and RC pumps. It was concluded that because of these differences the failures similar to RC pump shafts are not likely to appear in HT pump shafts. This conclusion is further reinforced by about 140,000 hours of operating history of the longest running HT pump of comparable size to RC Pumps, without failures

  1. CANDU fuel cycles - present and future

    International Nuclear Information System (INIS)

    Mooradian, A.J.

    1976-05-01

    The present commercially proven Canadian nuclear power system is based on a once-through natural uranium fuel cycle characterized by high uranium utilization and a high conversion efficiency. The cycle closes with secure retrievable storage of spent fuel. This cycle is based on a CANDU reactor concept which is now well understood. Both active and passive fuel storage options have been investigated and will be described in this paper. Future development of the CANDU system is focussed on conservation of uranium by plutonium and thorium recycle. The full exploitation of these options requires continued emphasis on neutron conservation, efficiency of extraction and fuel refabrication processes. The results of recent studies are discussed in this paper. (author)

  2. Moderator heat recovery of CANDU reactors

    International Nuclear Information System (INIS)

    Fath, H.E.S.; Ahmed, S.T.

    1986-01-01

    A moderator heat recovery scheme is proposed for CANDU reactors. The proposed circuit utilizes all the moderator heat to the first stages of the plant feedwater heating system. CANDU-600 reactors are considered with moderator heat load varying from 120 to 160 MWsub(th), and moderator outlet temperature (from calandria) varying from 80 to 100 0 C. The steam saved from the turbine extraction system was found to produce an additional electric power ranging from 5 to 11 MW. This additional power represents a 0.7-1.7% increase in the plant electric output power and a 0.2-0.7% increase in the plant thermal efficiency. The outstanding features and advantages of the proposed scheme are presented. (author)

  3. Development of modern CANDU PHWR cross-section libraries for SCALE

    International Nuclear Information System (INIS)

    Shoman, Nathan T.; Skutnik, Steven E.

    2016-01-01

    Highlights: • New ORIGEN libraries for CANDU 28 and 37-element fuel assemblies have been created. • These new reactor data libraries are based on modern ENDF/B-VII.0 cross-section data. • The updated CANDU data libraries show good agreement with radiochemical assay data. • Eu-154 overestimated when using ENDF-VII.0 due to a lower thermal capture cross-section. - Abstract: A new set of SCALE fuel lattice models have been developed for the 28-element and 37-element CANDU fuel assembly designs using modern cross-section data from ENDF-B/VII.0 in order to produce new reactor data libraries for SCALE/ORIGEN depletion analyses. These new libraries are intended to provide users with a convenient means of evaluating depletion of CANDU fuel assemblies using ORIGEN through pre-generated cross sections based on SCALE lattice physics calculations. The performance of the new CANDU ORIGEN libraries in depletion analysis benchmarks to radiochemical assay data were compared to the previous version of the CANDU libraries provided with SCALE (based on WIMS-AECL models). Benchmark comparisons with available radiochemical assay data indicate that the new cross-section libraries perform well at matching major actinide species (U/Pu), which are generally within 1–4% of experimental values. The library also showed similar or better results over the WIMS-AECL library regarding fission product species and minor actinoids (Np, Am, and Cm). However, a notable exception was in calculated inventories of "1"5"4Eu and "1"5"5Eu, where the new library employing modern nuclear data (ENDF/B-VII.0) performed substantially poorer than the previous WIMS-AECL library (which used ENDF-B/VI.8 cross-sections for these species). The cause for this discrepancy appears to be due to differences in the "1"5"4Eu thermal capture cross-section between ENDF/B-VI.8 and ENDF/B-VII.0, an effect which is exacerbated by the highly thermalized flux of a CANDU heavy water reactor compared to that of a typical

  4. Effect of DUPIC cycle on CANDU reactor safety parameters

    Energy Technology Data Exchange (ETDEWEB)

    Mohamed, Nader M. A. [Atomic Energy Authority, ETRR-2, Cairo (Egypt); Badawi, Alya [Dept. of Nuclear and Radiation Engineering, Alexandria University, Alexandria (Egypt)

    2016-10-15

    Although, the direct use of spent pressurized water reactor (PWR) fuel in CANda Deuterium Uranium (CANDU) reactors (DUPIC) cycle is still under investigation, DUPIC cycle is a promising method for uranium utilization improvement, for reduction of high level nuclear waste, and for high degree of proliferation resistance. This paper focuses on the effect of DUPIC cycle on CANDU reactor safety parameters. MCNP6 was used for lattice cell simulation of a typical 3,411 MWth PWR fueled by UO{sub 2} enriched to 4.5w/o U-235 to calculate the spent fuel inventories after a burnup of 51.7 MWd/kgU. The code was also used to simulate the lattice cell of CANDU-6 reactor fueled with spent fuel after its fabrication into the standard 37-element fuel bundle. It is assumed a 5-year cooling time between the spent fuel discharges from the PWR to the loading into the CANDU-6. The simulation was carried out to calculate the burnup and the effect of DUPIC fuel on: (1) the power distribution amongst the fuel elements of the bundle; (2) the coolant void reactivity; and (3) the reactor point-kinetics parameters.

  5. Economic Analysis on Direct Use of Spent Pressurized Water Reactor Fuel in CANDU Reactors - I: DUPIC Fuel Fabrication Cost

    International Nuclear Information System (INIS)

    Choi, Hangbok; Ko, Won Il; Yang, Myung Seung

    2001-01-01

    A preliminary conceptual design of a Direct Use of spent Pressurized water reactor (PWR) fuel In Canada deuterium uranium (CANDU) reactors (DUPIC) fuel fabrication plant was studied, which annually converts spent PWR fuel of 400 tonnes heavy element (HE) into CANDU fuel. The capital and operating costs were estimated from the viewpoint of conceptual design. Assuming that the annual discount rate is 5% during the construction (5 yr) and operation period (40 yr) and contingency is 25% of the capital cost, the levelized unit cost (LUC) of DUPIC fuel fabrication was estimated to be 616 $/kg HE, which is mostly governed by annual operation and maintenance costs that correspond to 63% of LUC. Among the operation and maintenance cost components being considered, the waste disposal cost has the dominant effect on LUC (∼49%). From sensitivity analyses of production capacity, discount rate, and contingency, it was found that the production capacity of the plant is the major parameter that affects the LUC

  6. Plutonium Consumption Program, CANDU Reactor Project final report

    Energy Technology Data Exchange (ETDEWEB)

    1994-07-31

    DOE is investigating methods for long term dispositioning of weapons grade plutonium. One such method would be to utilize the plutonium in Mixed OXide (MOX) fuel assemblies in existing CANDU reactors. CANDU (Canadian Deuterium Uranium) reactors are designed, licensed, built, and supported by Atomic Energy of Canada Limited (AECL), and currently use natural uranium oxide as fuel. The MOX spent fuel assemblies removed from the reactor would be similar to the spent fuel currently produced using natural uranium fuel, thus rendering the plutonium as unattractive as that in the stockpiles of commercial spent fuel. This report presents the results of a study sponsored by the DOE for dispositioning the plutonium using CANDU technology. Ontario Hydro`s Bruce A was used as reference. The fuel design study defined the optimum parameters to disposition 50 tons of Pu in 25 years (or 100 tons). Two alternate fuel designs were studied. Safeguards, security, environment, safety, health, economics, etc. were considered. Options for complete destruction of the Pu were also studied briefly; CANDU has a superior ability for this. Alternative deployment options were explored and the potential impact on Pu dispositioning in the former Soviet Union was studied. An integrated system can be ready to begin Pu consumption in 4 years, with no changes required to the reactors other than for safe, secure storage of new fuel.

  7. Plutonium Consumption Program, CANDU Reactor Project final report

    International Nuclear Information System (INIS)

    1994-01-01

    DOE is investigating methods for long term dispositioning of weapons grade plutonium. One such method would be to utilize the plutonium in Mixed OXide (MOX) fuel assemblies in existing CANDU reactors. CANDU (Canadian Deuterium Uranium) reactors are designed, licensed, built, and supported by Atomic Energy of Canada Limited (AECL), and currently use natural uranium oxide as fuel. The MOX spent fuel assemblies removed from the reactor would be similar to the spent fuel currently produced using natural uranium fuel, thus rendering the plutonium as unattractive as that in the stockpiles of commercial spent fuel. This report presents the results of a study sponsored by the DOE for dispositioning the plutonium using CANDU technology. Ontario Hydro's Bruce A was used as reference. The fuel design study defined the optimum parameters to disposition 50 tons of Pu in 25 years (or 100 tons). Two alternate fuel designs were studied. Safeguards, security, environment, safety, health, economics, etc. were considered. Options for complete destruction of the Pu were also studied briefly; CANDU has a superior ability for this. Alternative deployment options were explored and the potential impact on Pu dispositioning in the former Soviet Union was studied. An integrated system can be ready to begin Pu consumption in 4 years, with no changes required to the reactors other than for safe, secure storage of new fuel

  8. Highlights of the metallurgical behaviour of CANDU pressure tubes

    International Nuclear Information System (INIS)

    Price, E.G.

    1984-10-01

    This paper is an overview of the service induced metallurgical changes that take place in Zircaloy-2 and Zr-2.5 wt. percent Nb pressure tubes in CANDU reactors. It incorporates the findings of an evaluation program, that followed a significant pressure tube failure at Ontario Hydro's Pickering Nuclear Generating Station, and also provides valid reasons for continued confidence in the current CANDU design

  9. Optimizing in-bay fuel inspection capability to meet the needs of today's CANDU fleet

    International Nuclear Information System (INIS)

    St-Pierre, J.; Simons, B.

    2013-01-01

    With the recent return to service of many CANDU units, aging of all others, increasingly competitive energy market and aging hot cell infrastructure - there exists now a greater need for timely, cost-effective and reliable collection of irradiated fuel performance information from fuel bay inspections. The recent development of simple in-bay tools, used in combination with standardized technical specifications, inspection databases and assessment techniques, allows utilities to characterize the condition of irradiated fuel and any debris lodged in the bundle in a more timely fashion and more economically than ever. Use of these tools and 'advanced' techniques permits timely engineering review and disposition of emerging issues to support reliable operation of the CANDU fleet. (author)

  10. Optimizing in-bay fuel inspection capability to meet the needs of today's CANDU fleet

    Energy Technology Data Exchange (ETDEWEB)

    St-Pierre, J., E-mail: joe.st-pierre@amec.com [AMEC NSS, Toronto, Ontario (Canada); Simons, B. [Stern Laboratories Incorporated, Hamilton, Ontario (Canada)

    2013-07-01

    With the recent return to service of many CANDU units, aging of all others, increasingly competitive energy market and aging hot cell infrastructure - there exists now a greater need for timely, cost-effective and reliable collection of irradiated fuel performance information from fuel bay inspections. The recent development of simple in-bay tools, used in combination with standardized technical specifications, inspection databases and assessment techniques, allows utilities to characterize the condition of irradiated fuel and any debris lodged in the bundle in a more timely fashion and more economically than ever. Use of these tools and 'advanced' techniques permits timely engineering review and disposition of emerging issues to support reliable operation of the CANDU fleet. (author)

  11. CANDU, building the future

    International Nuclear Information System (INIS)

    Stern, F.

    1997-01-01

    The CEO of Stern Laboratories delivered a speech on the problems and challenges facing the nuclear industry. The CANDU system is looked at as the practical choice for the future of our energy source. The people of the industry must be utilized and respected to deliver to the best of their ability

  12. CANDU, building the future

    Energy Technology Data Exchange (ETDEWEB)

    Stern, F. [Stern Laboratories (Canada)

    1997-07-01

    The CEO of Stern Laboratories delivered a speech on the problems and challenges facing the nuclear industry. The CANDU system is looked at as the practical choice for the future of our energy source. The people of the industry must be utilized and respected to deliver to the best of their ability.

  13. Signal de-noising methods for fault diagnosis and troubleshooting at CANDU{sup ®} stations

    Energy Technology Data Exchange (ETDEWEB)

    Nasimi, Elnara; Gabbar, Hossam A., E-mail: hossam.gabbar@uoit.ca

    2014-12-15

    Highlights: • Fault modelling using a Fault Semantic Network (FSN). • Intelligent filtering techniques for signal de-noise in NPP. • Signal feature extraction is applied as integrated with FSN. • Increase signal-to-noise ratio (SNR). - Abstract: Over the past several years a number of domestic CANDU{sup ®} stations have experienced issues with neutron detection systems that challenged safety and operation. Intelligent troubleshooting methodology is required to aid in making risk-informed decisions related to design and operational activities, which can aid current stations and be used for the future generation of CANDU{sup ®} designs. Fault modelling approach using Fault Semantic Network (FSN) with risk estimation is proposed for this purpose. One major challenge in troubleshooting is the determination of accurate data. It is typical to have missing, incomplete or corrupted data points in large process data sets from dynamically changing systems. Therefore, it is expected that quality of obtained data will have a direct impact on the system's ability to recognize developing trends in the process upset situations. In order to enable fault detection process, intelligent filtering techniques are required to de-noise process data and extract valuable signal features in the presence of background noise. In this study, the impact of applying an optimized and intelligent filtering of process signals prior to data analysis is discussed. This is particularly important for neutronic signals in order to increase signal-to-noise ratio (SNR) which suffers the most during start-ups and low power operation. This work is complimentary to the previously published studies on FSN-based fault modelling in CANDU stations. The main objective of this work is to explore the potential research methods using a specific case study and, based on the results and outcomes from this work, to note the possible future improvements and innovation areas.

  14. Results of the CANDU 3 probabilistic safety assessment

    Energy Technology Data Exchange (ETDEWEB)

    Jaitly, R K [Atomic Energy of Canada Ltd., Saskatoon, SK (Canada)

    1996-12-31

    The purpose of the Conceptual Probabilistic Safety Assessment (PSA) of the CANDU 3 reactor was to provide safety assistance in the early stages of design to ensure that the design included adequate redundancy and functional separation of the mitigating systems; the final design should therefore give better results, particularly after modifications involving control, electrical power, instrument air, and service water. The initial PSA gave a total CANDU 3 core damage frequency of 7.8 x 10{sup -6}/year. 4 refs., 1 fig.

  15. Results of the CANDU 3 probabilistic safety assessment

    International Nuclear Information System (INIS)

    Jaitly, R.K.

    1995-01-01

    The purpose of the Conceptual Probabilistic Safety Assessment (PSA) of the CANDU 3 reactor was to provide safety assistance in the early stages of design to ensure that the design included adequate redundancy and functional separation of the mitigating systems; the final design should therefore give better results, particularly after modifications involving control, electrical power, instrument air, and service water. The initial PSA gave a total CANDU 3 core damage frequency of 7.8 x 10 -6 /year. 4 refs., 1 fig

  16. Integrated control centre concepts for CANDU power plants

    International Nuclear Information System (INIS)

    Lupton, L.R.; Davey, E.C.; Lapointe, P.A.; Shah, R.R.

    1990-01-01

    The size and complexity of nuclear power plants has increased significantly in the last 20 years. There is general agreement that plant safety and power production can be enhanced if more operational support systems that are significantly different from the ones based on the more conventional technologies used in plant control rooms. In particular, artificial intelligence and related technologies will play a major role in the development of innovative methods for information processing and presentation. These technologies must be integrated into the overall management and control philosophy of the plant and not be treated as vehicles to implement point solutions. The underlying philosophy behind our approach is discussed in this paper. Operator support systems will integrate into the overall control philosophy by complementing the operator. Four support systems are described; each is a prototype of a system being considered for the CANDU 3 control centre

  17. Integrated control centre concepts for CANDU power plants

    Energy Technology Data Exchange (ETDEWEB)

    Lupton, L. R.; Davey, E. C.; Lapointe, P. A.; Shah, R. R.

    1990-01-15

    The size and complexity of nuclear power plants has increased significantly in the last 20 years. There is general agreement that plant safety and power production can be enhanced if more operational support systems that are significantly different from the ones based on the more conventional technologies used in plant control rooms. In particular, artificial intelligence and related technologies will play a major role in the development of innovative methods for information processing and presentation. These technologies must be integrated into the overall management and control philosophy of the plant and not be treated as vehicles to implement point solutions. The underlying philosophy behind our approach is discussed in this paper. Operator support systems will integrate into the overall control philosophy by complementing the operator. Four support systems are described; each is a prototype of a system being considered for the CANDU 3 control centre.

  18. Specific aspects in the manufacturing and operating of CANDU reactor pressure tubes (P/T)

    International Nuclear Information System (INIS)

    Muscaloiu, C.

    1997-01-01

    The CANDU reactor design is based on a number of individual P/T in which nuclear fuel bundles are located. P/T are required to be operated in an environment of elevated temperature (300 o C), internal pressure (10 Mpa), fast neutron flux (E>1 MeV) and heavy water. The most suitable material which can provide the desired neutron economy and still maintain its mechanical properties along with corrosion resistance is zirconium alloys Zr+ 2.5 % Nb with the following composition: niobium, 2.5 to 2.8 weight percent; oxygen, 1,000 to 1,300 ppm; zirconium + allowed impurities - balance. A total of 380 pressure tubes are installed into reactor. Each pressure tube is attached at each end to a stainless steel end fitting by means of a grooved, expanded joint. The installation works were performed by ANM Bucuresti, under the technical support of General Electric Canada. The integrity of P/T after installation was examined as follows: - the surface of the rolled area on unrolled internal surface extending 25 mm beyond rolled area was inspected for irregularities by means of a boroscope; - all pressure tubes were subjected to the helium leak test after F/C installation. During P/T operating life periodical inspections according to Canadian Standard CSA N285.4 are performed. The selection of the P/T for inspection is based either on particular properties or on the operating conditions of the fuel channel. The inspection consists in: a) Base Line Inspection within 2 years period commencing after 7,000 EFPH of operation which will include a volumetric inspection over P/T full length and measurements of P/T sag, ID, wall thickness and F/C bearing positions; b) Periodic Inspection in the same conditions plus material surveillance (on the four most significant indication P/T detected during the Base Line Inspection). The inspection will be performed on 14 selected P/T. (author)

  19. CANDU project development

    International Nuclear Information System (INIS)

    Hedges, K.R.

    1995-01-01

    Advanced CANDU reactor design strategy follows an evolutionary approach, taking manageable steps in the development of power plants from today's available designs, and in parallel carrying out longer-term studies to develop future-generation reactor concepts. The major emphasis is on safety, on on reducing cost and schedule. New features are developed and thoroughly proof-tested before introduction into designs, in order to maximize owner confidence. (author). 4 figs

  20. CANDU project development

    Energy Technology Data Exchange (ETDEWEB)

    Hedges, K R [Atomic Energy of Canada Ltd., Mississauga, ON (Canada)

    1996-12-31

    Advanced CANDU reactor design strategy follows an evolutionary approach, taking manageable steps in the development of power plants from today`s available designs, and in parallel carrying out longer-term studies to develop future-generation reactor concepts. The major emphasis is on safety, on on reducing cost and schedule. New features are developed and thoroughly proof-tested before introduction into designs, in order to maximize owner confidence. (author). 4 figs.