Sample records for cable insulation materials

  1. Insulating materials for cables: state of the technology and future developments

    Energy Technology Data Exchange (ETDEWEB)

    Blechschmidt, H H [Hessische Elektrizitaets-A.G., Darmstadt (Germany, F.R.)

    1977-02-01

    This article gives a summary of old and new insulating materials for electrical cables. The electrical properties of some polymer insulating materials (PVC, polyethelene (PE), polymerised polyethelene (VPE), polypropylene) are compared in a table with the properties of paper insulation. The changeover from oiled paper to plastic insulation is almost complete for low voltage cables. Soft PVC is the dominant insulating material in this field. For medium voltage cables (10 kV and 20 kV supplies) and for high voltage cables (60 kV and 110 kV supplies) there is a trend to plastic PE/VPE, because these insulating materials have better electrical properties than PVC.

  2. Similarity Analysis of Cable Insulations by Chemical Test

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Jong Seog [Central Research Institute of Korea Hydro and Nuclear Power Co., Daejeon (Korea, Republic of)

    2013-10-15

    As result of this experiment, it was found that FT-IR test for material composition, TGA test for aging trend are applicable for similarity analysis of cable materials. OIT is recommended as option if TGA doesn't show good trend. Qualification of new insulation by EQ report of old insulation should be based on higher activation energy of new insulation than that of old one in the consideration of conservatism. In old nuclear power plant, it is easy to find black cable which has no marking of cable information such as manufacturer, material name and voltage. If a type test is required for qualification of these cables, how could I select representative cable? How could I determine the similarity of these cables? If manufacturer has qualified a cable for nuclear power plant more than a decade ago and composition of cable material is changed with similar one, is it acceptable to use the old EQ report for recently manufactured cable? It is well known to use FT-IR method to determine the similarity of cable materials. Infrared ray is easy tool to compare compositions of each material. But, it is not proper to compare aging trend of these materials. Study for similarity analysis of cable insulation by chemical test is described herein. To study a similarity evaluation method for polymer materials, FT-IR, TGA and OIT tests were performed for two cable insulation(old and new) which were supplied from same manufacturer. FT-IR shows good result to compare material compositions while TGA and OIT show good result to compare aging character of materials.

  3. Similarity Analysis of Cable Insulations by Chemical Test

    International Nuclear Information System (INIS)

    Kim, Jong Seog

    2013-01-01

    As result of this experiment, it was found that FT-IR test for material composition, TGA test for aging trend are applicable for similarity analysis of cable materials. OIT is recommended as option if TGA doesn't show good trend. Qualification of new insulation by EQ report of old insulation should be based on higher activation energy of new insulation than that of old one in the consideration of conservatism. In old nuclear power plant, it is easy to find black cable which has no marking of cable information such as manufacturer, material name and voltage. If a type test is required for qualification of these cables, how could I select representative cable? How could I determine the similarity of these cables? If manufacturer has qualified a cable for nuclear power plant more than a decade ago and composition of cable material is changed with similar one, is it acceptable to use the old EQ report for recently manufactured cable? It is well known to use FT-IR method to determine the similarity of cable materials. Infrared ray is easy tool to compare compositions of each material. But, it is not proper to compare aging trend of these materials. Study for similarity analysis of cable insulation by chemical test is described herein. To study a similarity evaluation method for polymer materials, FT-IR, TGA and OIT tests were performed for two cable insulation(old and new) which were supplied from same manufacturer. FT-IR shows good result to compare material compositions while TGA and OIT show good result to compare aging character of materials

  4. Treeing phenomenon of thermoplastic polyethylene blends for recyclable cable insulation materials

    Science.gov (United States)

    Li, Lunzhi; Zhang, Kai; Zhong, Lisheng; Gao, Jinghui; Xu, Man; Chen, Guanghui; Fu, Mingli

    2017-02-01

    Owing to its good recyclability and low processing energy consumption, non-crosslinked polyethylene blends (e.g. LLDPE-HDPE blends) are considered as one of potential environmental-friendly substitutions for crosslinked polyethylene (XLPE) as cable insulation material. Although extensive work has been performed for measuring the basic dielectric properties, there is a lack of the investigations on the aging properties for such a material system, which hinders the evaluation of reliability and lifetime of the material for cable insulation. In this paper, we study the electric aging phenomenon of 0.7LLDPE-0.3HDPE blending material by investigating the treeing behavior, and its comparison with XLPE and LLDPE. Treeing tests show that the 0.7LLDPE-0.3HDPE blends have lower probability for treeing as well as smaller treeing dimensions. Further thermal analysis and microstructure study results suggest that the blends exhibit larger proportion of thick lamellae and higher crystallinity with homogeneously-distributed amorphous region, which is responsible for good anti-treeing performance. Our finding provides the evidence that the 0.7LLDPE-0.3HDPE blends exhibits better electric-aging-retardance properties than XLPE, which may result in a potential application for cable insulation.

  5. Treeing phenomenon of thermoplastic polyethylene blends for recyclable cable insulation materials

    Directory of Open Access Journals (Sweden)

    Lunzhi Li

    2017-02-01

    Full Text Available Owing to its good recyclability and low processing energy consumption, non-crosslinked polyethylene blends (e.g. LLDPE-HDPE blends are considered as one of potential environmental-friendly substitutions for crosslinked polyethylene (XLPE as cable insulation material. Although extensive work has been performed for measuring the basic dielectric properties, there is a lack of the investigations on the aging properties for such a material system, which hinders the evaluation of reliability and lifetime of the material for cable insulation. In this paper, we study the electric aging phenomenon of 0.7LLDPE-0.3HDPE blending material by investigating the treeing behavior, and its comparison with XLPE and LLDPE. Treeing tests show that the 0.7LLDPE-0.3HDPE blends have lower probability for treeing as well as smaller treeing dimensions. Further thermal analysis and microstructure study results suggest that the blends exhibit larger proportion of thick lamellae and higher crystallinity with homogeneously-distributed amorphous region, which is responsible for good anti-treeing performance. Our finding provides the evidence that the 0.7LLDPE-0.3HDPE blends exhibits better electric-aging-retardance properties than XLPE, which may result in a potential application for cable insulation.

  6. Safety research of insulating materials of cable for nuclear power generating station

    Science.gov (United States)

    Lee, C. K.; Choi, J. H.; Kong, Y. K.; Chang, H. S.

    1988-01-01

    The polymers PE, EPR, PVC, Neoprene, CSP, CLPE, EP and other similar substances are frequently used as insulation and protective covering for cables used in nuclear power generating stations. In order to test these materials for flame retardation, environmental resistance, and cable specifications, they were given the cable normal test, flame test, chemical tests, and subjected to design analysis and loss of coolant accident tests. Material was collected on spark tests and actual experience standards were established through these contributions and technology was accumulated.

  7. Compilation of radiation damage test data cable insulating materials

    CERN Document Server

    Schönbacher, H; CERN. Geneva

    1979-01-01

    This report summarizes radiation damage test data on commercially available organic cable insulation and jacket materials: ethylene- propylene rubber, Hypalon, neoprene rubber, polyethylene, polyurethane, polyvinylchloride, silicone rubber, etc. The materials have been irradiated in a nuclear reactor to integrated absorbed doses from 5*10/sup 5/ to 5*10/sup 6/ Gy. Mechanical properties, e.g. tensile strength, elongation at break, and hardness, have been tested on irradiated and non-irradiated samples. The results are presented in the form of tables and graphs, to show the effect of the absorbed dose on the measured properties. (13 refs).

  8. Development of radiation resistant PEEK insulation cable

    International Nuclear Information System (INIS)

    Mio, Keigo; Ogiwara, Norio; Hikichi, Yusuke; Furukori, Hisayoshi; Arai, Hideyuki; Nishizawa, Daiji; Nishidono, Toshiro

    2009-04-01

    Material characterization and development has been carried out for cable insulation suitable for use in the J-PARC 3-GeV RCS radiation environment. In spite of its high cost, PEEK (polyether-ether-ketone) has emerged as the leading candidate satisfying requirements of being non-halogen based, highly incombustible and with radiation resistant at least 10 MGy, along with the usual mechanical characteristics such as good elongation at break, which are needed in a cable insulation. Gamma-ray irradiation tests have been done in order to study radiation resistance of PEEK cable. Further, mechanical, electrical and fire retardant characteristics of a complete cable such as would be used at the J-PARC RCS were investigated. As a result, PEEK cables were shown to be not degraded by radiation up to at least 10 MGy, and thus could be expected to operate stably under the 3-GeV RCS radiation environment. (author)

  9. Microwave heating of electric cable insulated wires before their impregnation with a hydrophobic material

    Energy Technology Data Exchange (ETDEWEB)

    Niculae, D; Mihailescu, A [Romanian Electricity Authority (Romania); Indreias, I; Martin, D [Institute of Atomic Physics, Bucharest (Romania); Margaritescu, A [ICPE Electrostatica, Bucharest, (Romania); Zlatonovici, D

    1998-12-31

    Underground insulated telecommunication cables must be impregnated with a hydrophobic material in order to prevent water penetration damage. To do so, the cable wire bundle must be heated to a temperature of 60 to 90 degrees C to ensure proper fluidity of the hydrophobic material that must fill the free spaces between the copper wires of the telephone cable. This paper described the microwave heating method of the wires before their impregnation. A cylindrical applicator was designed to perform a telephone bundle heating test. 800 W of microwave power were used on a telephone cable made up of 800 wires of 0.4 mm in diameter. A uniform heating was obtained throughout the section. Microwave heating was also found to be 53 per cent more energy efficient than hot air heating. 4 refs., 4 figs.

  10. Air insulated cables for medium and low voltage supplies of the EVU

    Energy Technology Data Exchange (ETDEWEB)

    Dienstel, S

    1977-02-01

    Air insulated cables and insulated overhead cables are electrical components, which, by the use of new insulating materials and technology, are particularly suitable for the introduction of systems for overhead power transmission plants. They combine the favorable properties of underground cables, such as compact construction and low inductance, with their high mechanical strength. The present report deals with the construction, accessories and technical properties of these cables. The constructional and operational aspects of such systems and their costs are also discussed.

  11. High-voltage polymeric insulated cables

    Energy Technology Data Exchange (ETDEWEB)

    Ross, A

    1987-01-01

    Reviews developments in high-voltage (here defined as 25 kV, 66 kV and 132 kV) polymeric insulated cables in the UK over the period 1979-1986, with particular reference to the experience of the Eastern Electricity Board. Outlines the background to the adoption of XPLE-insulated solid cable, and the design, testing, terminations, jointing and costs of 25 kV, 66 kV and 132 kV cables.

  12. Built-in unit with short-circuit insulation for hermetic cable ducts

    International Nuclear Information System (INIS)

    Tschacher, B.; Gurr, W.; Kusserow, J.; Katzmarek, W.

    1984-01-01

    The invention concerns a built-in unit with short-circuit insulation for hermetic cable ducts, especially for containments of nuclear power reactors. The short-circuit insulation is achieved by an insulation plate made from radiation-resistant insulating materials of high mechanical strength

  13. Application of optical diagnosis to aged low-voltage cable insulation in nuclear plants

    International Nuclear Information System (INIS)

    Katagiri, Junichi; Takezawa, Yoshitaka; Shouji, Hiroshi

    2008-01-01

    We have developed a novel non-destructive optical diagnosis technique for low-voltage cable insulations used in nuclear power plants. The key features of this diagnosis are the use of two wavelengths to measure the change in reflective absorbance (ΔA R ), the use of polarized light to measure crystallinity and the use of element volatilizing to measure fluorescence. Chemical kinetics is used to predict the lifetimes of the cable insulations. When cable insulations darken and harden by time degradation, the ΔA R and depolarization parameters increase. This means that the cross-linking density in the cable insulations increases due to deterioration reactions. When the cross-linking density of insulation increases, its elasticity, corresponding to the material's life, increases. Similarly, as the crystallinity increases due to the change in the high-order structure of the insulating resin caused by irradiation, its elongation property decreases. The elongation property of insulation is one of the most important parameters that can be used to evaluate material lifetimes, because it relates to elasticity. The ΔA R correlated with the elongation property, and the correlation coefficient of an accelerated experiment using model pieces was over 0.9. Thus, we concluded that this optical diagnosis should be applied to evaluate the degradation of cable insulations used in nuclear power plants. (author)

  14. Analysis of Insulating Material of XLPE Cables considering Innovative Patterns of Partial Discharges

    Directory of Open Access Journals (Sweden)

    Fernando Figueroa Godoy

    2017-01-01

    Full Text Available This paper aims to analyze the quality of insulation in high voltage underground cables XLPE using a prototype which classifies the following usual types of patterns of partial discharge (PD: (1 internal PD, (2 superficial PD, (3 corona discharge in air, and (4 corona discharge in oil, in addition to considering two new PD patterns: (1 false contact and (2 floating ground. The tests and measurements to obtain the patterns and study cases of partial discharges were performed at the Testing Laboratory Equipment and Materials (LEPEM of the Federal Electricity Commission of Mexico (CFE using a measuring equipment LDIC and norm IEC60270. To classify the six patterns of partial discharges mentioned above a Probabilistic Neural Network Bayesian Modified (PNNBM method having the feature of using a large amount of data will be used and it is not saturated. In addition, PNN converges, always finding a solution in a short period of time with low computational cost. The insulation of two high voltage cables with different characteristics was analyzed. The test results allow us to conclude which wire has better insulation.

  15. Aging predictions in nuclear power plants: Crosslinked polyolefin and EPR cable insulation materials

    International Nuclear Information System (INIS)

    Gillen, K.T.; Clough, R.L.

    1991-06-01

    In two earlier reports, we derived a time-temperature-dose rate superposition methodology, which, when applicable, can be used to predict cable degradation versus dose rate, temperature and exposure time. This methodology results in long-term predictive capabilities at the low dose rates appropriate to ambient nuclear power plant aging environments. The methodology was successfully applied to numerous important cable materials used in nuclear applications and the extrapolated predictions were verified by comparisons with long-term (7 to 12 year) results for similar or identical materials aged in nuclear environments. In this report, we test the methodology on three crosslinked polyolefin (CLPO) and two ethylene propylene rubber (EPR) cable insulation materials. The methodology applies to one of the CLPO materials and one of the EPR materials, allowing predictions to be made for these materials under low dose-rate, low temperature conditions. For the other materials, it is determined that, at low temperatures, a decrease in temperature at a constant radiation dose rate leads to an increase in the degradation rate for the mechanical properties. Since these results contradict the fundamental assumption underlying time-temperature-dose rate superposition, this methodology cannot be applied to such data. As indicated in the earlier reports, such anomalous results might be expected when attempting to model data taken across the crystalline melting region of semicrystalline materials. Nonetheless, the existing experimental evidence suggests that these CLPO and EPR materials have substantial aging endurance for typical reactor conditions. 28 refs., 26 figs., 3 tabs

  16. Crosslinking of wire and cable insulation using electron accelerators

    International Nuclear Information System (INIS)

    Feng Yongxiang; Ma Zueteh

    1992-01-01

    Radiation crosslinking of wire and cable insulation is a well-established technology that is widely used in industry. The advantages of radiation crosslinking over chemical crosslinking have helped maintain its steady growth. Since successful utilization of electron beam processing relies on the formulation of compounds used in insulation, the radiation crosslinking of various polymers is reviewed. The handling technology for crosslinking wire and cable insulation and the throughput capacity of electron beam processors are also discussed. More than 30% of the industrial electron accelerators in the world are used for the radiation crosslinking of wire and cable insulation. Prospects of increased use of electron accelerators for crosslinking of wire and cable insulation are very good. (orig.)

  17. Effect of oxygen in the simulated LOCA environments of the degradation of cable insulating materials

    International Nuclear Information System (INIS)

    Kusuma, Y.; Okada, S.; Itoh, M.; Yagi, T.; Yoshikawa, M.; Yoshida, K.; Machi, S.; Tamura, N.; Kawakami, W.

    1990-01-01

    Five kinds of insulating and jacketing materials for the cables used in nuclear power plants were exposed to various LOCA environments of both simultaneous and sequential methods using SEAMATE-II. Experimental conditions of the simultaneous LOCA tests were done at different radiation dose rate, steam temperature and amount of air added to the LOCA environments. The sequential tests consist of two stages, that is, pre-irradiation and subsequent steam/spray exposure. Pre-irradiation conditions and subsequent steam/spray exposure conditions of the sequential LOCA tests are systematically changed in order to find appropriate conditions which can bring about the degradation of same degree to those obtained for various simultaneous LOCA simulations. Tensile properties, insulating resistance and water sorption of the insulating materials exposed to various LOCA environments are measured and discussed. (author). 11 refs, 19 figs, 3 tabs

  18. Long-term radiation effects on commercial cable-insulating materials irradiated at CERN

    International Nuclear Information System (INIS)

    Maier, P.; Stolarz, A.

    1983-01-01

    Long-term irradiation damage tests have been carried out on a variety of flexible cable-insulating materials offered to CERN by different European cable manufacturers. Tensile test specimens were exposed for a maximum of three years in high-level radiation areas of the Super Proton Synchrotron (SPS) and for comparison at high dose rates in a nuclear reactor. The degradation of mechanical properties after irradiation in air depends not only on the total absorbed dose, but also on the dose rate for most of these polymer compounds. These dose-rate effects vary between material types and for different compounds. The results presented here illustrate the difference in radiation damage between short-term and long-term irradiation conditions in a typical service application for the various materials tested. They also allow safety factors to be estimated for the extrapolation of the limiting exposure in service from accelerated material tests in the range of dose rates covered. A discussion of the available models of the dose-rate effects results in a conservative estimate for extrapolation to low dose rates from measured values at intermediate dose rates of the order of 0.1 Gy/s. Based on short-term irradiation tests only, the safety factors to be applied depend on the end-point criterion used, and may vary between 1 and 10 for the range of dose rates and materials considered here. (orig.)

  19. Electric cable insulation pyrolysis and ignition resulting from potential hydrogen burn scenarios for nuclear containment buildings

    International Nuclear Information System (INIS)

    Berlad, A.L.; Jaung, R.; Pratt, W.T.

    1982-01-01

    Electric cable insulation in nuclear containment buildings may participate in pyrolysis and combustion processes engendered by hydrogen burn phenomena. This paper examines these pyrolysis/ignition processes of those polymeric materials present in the electric cable insulation and their possible relation to hydrogen burn scenarios

  20. Microscopic Void Detection for Predicting Remaining Life in Electric Cable Insulation

    International Nuclear Information System (INIS)

    Horvath, David A.; Avila, Steven M.

    2003-01-01

    A reliable method of testing for remaining life in electric cable insulation has continued to elude the nuclear industry as it seeks to extend the life and license of its nuclear stations. Until recently, a trendable, measurable electrical property has not been found, and unexpected cable failures continue to be reported. Most reliable approaches to date rely on monitoring mechanical properties, which are assumed to degrade faster than the insulation's electrical properties. This paper introduces a promising technique based on void characterization, which is dependent on an electrical property related to dielectric strength. A relationship between insulation void characteristics (size and density) and the onset of partial discharge is known to exist. A similar relationship can be shown between void characteristics and unacceptable leakage currents (another typical cable failure criterion). For low-voltage cables, it is believed void content can be correlated to mechanical property degradation.This paper will report on an approach for using void information, research results showing the existence of trendable void characteristics in commonly used electric insulation materials, and techniques for detecting the voids (both laboratory- and field-based techniques). Acoustical microscopy was found to be potentially more suitable than conventional ultrasound for nondestructive in situ detection and monitoring of void characteristics in jacketed multiconductor insulation while ignoring the jacket. Also, optical and scanning electron microscope techniques will play an essential role in establishing the database necessary for continued development and implementation of this promising technique

  1. Crystal River 3 Cable Materials for Thermal and Gamma Radiation Aging

    Energy Technology Data Exchange (ETDEWEB)

    Fifield, Leonard S. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Correa, Miguel [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Zwoster, Andy [Pacific Northwest National Lab. (PNNL), Richland, WA (United States)

    2017-09-07

    The Expanded Materials Degradation Assessment Volume 5: Aging of Cables and Cable Systems (EMDA) summarizes the state of knowledge of materials, constructions, operating environments, and aging behavior of low voltage and medium cables in nuclear power plants (NPPs) and identifies potential knowledge gaps with regard to cable operation beyond 60 years. The greatest area of uncertainty relates to how well the accelerated aging used in the original equipment qualification (EQ) processes predicts the performance of cable materials in extended operation. General opinion and utility experience have indicated that actual operating environments of in-plant cables are not as severe, however, as the operating and design basis environments used in the qualification process. Better understanding of the long term aging behavior of cable insulation materials in service conditions and the analysis of actual cable operating environments are the objectives of ongoing research to support subsequent license renewal activities in particular and long term cable aging management in general. A key component of the effort to better understand cable material aging behavior is the availability of representative samples of cables that have been installed in operating light water reactors and have experienced long term service. Unique access to long term service cables, including relatively rich information on cable identity and history, occurred in 2016 through the assistance of the Electric Power Research Institute (EPRI). EPRI facilitated DOE receipt of harvested cables from the decommissioned Crystal River Unit 3 (CR3) pressurized water reactor representing six of the nine most common low voltage cable manufacturers (EPRI 103841R1): Rockbestos, Anaconda Wire and Cable Company (Anaconda), Boston Insulated Wire (BIW), Brand-Rex, Kerite and Okonite. Cable samples received had been installed in the operating plant for durations ranging from 10 years to 36 years. These cables provide the

  2. Development mineral insulated cables for nuclear instrumentation of reactors

    International Nuclear Information System (INIS)

    Calvo, W.A.P.; Hess Junior, A.; Brito Maciel, R. de

    1990-01-01

    In-core and out-of-core neutron detectors for reactor and safety control systems are usually connected by means of mineral insulated cables. The electrical signal, either a pulse or a current, is transmitted along the cable at high temperature, pressure and radiation and should not be influenced by electromagnetic interfereces from the environment. In this paper it is presented the result of the analysis of the mechanical and electrical properties of several types of mineral insulated cables and also the design, manufacture, sealing, cable ends and their applications to nuclear detectors of various types. (author) [pt

  3. Improved cable insulation for superconducting magnets

    International Nuclear Information System (INIS)

    Anerella, M.; Ghosh, A.K.; Kelly, E.; Schmalzle, J.; Willen, E.; Fraivillig, J.; Ochsner, J.; Parish, D.J.

    1993-01-01

    Several years ago, Brookhaven joined with DuPont in a cooperative effort to develop improved cable insulation for SSC superconducting dipole magnets. The effort was supported by the SSC Central Design Group and later the SSC Laboratory. It was undertaken because turn-to-turn and midplane shorts were routinely being experienced during the assembly of magnets with coils made of the existing Kapton/Fiberglass (K/FG) system of Kapton film overwrapped with epoxy-impregnated fiberglass tape. Dissection of failed magnets showed that insulation disruption and punch-through was occurring near the inner edges of turns close to the magnet midplane. Coil pressures of greater than 17 kpsi were sufficient to disrupt the insulation at local high spots where wires in neighboring turns crossed one another and where the cable had been strongly compacted in the keystoning operation during cable manufacture. In the joint development program, numerous combinations of polyimide films manufactured by DuPont with varying configurations and properties (including thickness) were subjected to tests at Brookhaven. Early tests were bench trials using wrapped cable samples. The most promising candidates were used in coils and many of these assembled and tested as magnets in both the SSC and RHIC magnet programs currently underway. The Kapton CI (CI) system that has been adopted represents a suitable compromise of numerous competing factors. It exhibits improved performance in the critical parameter of compressive punch-through resistance as well as other advantages over the K/FG system

  4. Improved cable insulation for superconducting magnets

    International Nuclear Information System (INIS)

    Anerella, M.; Ghosh, A.K.; Kelly, E.; Schmalzle, J.; Willen, E.; Fraivillig, J.; Ochsner, J.; Parish, D.J.

    1993-01-01

    Several years ago, Brookhaven joined with DuPont in a cooperative effort to develop improved cable insulation for SSC superconducting dipole magnets. The effort was supported by the SSC Central Design Group and later the SSC Laboratory. It was undertaken because turn-to-turn and midplane shorts were routinely being experienced during the assembly of magnets with coils made of the existing Kapton/fiberglass (K/FG) system of Kapton film overwrapped with epoxy-impregnated fiberglass tape. Dissection of failed magnets showed that insulation disruption and punch-through was occurring near the inner edges of turns close to the magnet midplane. Coil pressures of greater than 17 kpsi were sufficient to disrupt the insulation at local high spots where the cable had been strongly compacted in the keystoning operation during cable manufacture. In the joint development program, numerous combinations of polyimide films manufactured by DuPont with varying configurations and properties (including thickness) were subjected to tests at Brookhaven. Early tests were bench trials using wrapped cable samples. The most promising candidates were used in coils and many of these promising candidates were used in coils and many of these assembled and tested as magnets in both the SSC and RHIC magnet programs currently underway. The Kapton CI (CI) system that has been adopted represents a suitable compromise of numerous competing factors. It exhibits improved performance in the critical parameter of compressive punch-through resistance as well as other advantages over the K/FG system

  5. Electrical Insulation of 500-m High-Tc Superconducting Power Cable

    International Nuclear Information System (INIS)

    Takahashi, T; Ichikawa, M; Suzuki, H; Okamoto, T; Akita, S; Mukoyama, S; Yagi, M; Maruyama, S; Kimura, A

    2006-01-01

    Electrical insulation is one of the essential technologies for the electric power apparatus. Determination of testing voltages and design method of the electrical insulation layer are inextricably linked each other, and are critical to developing and realizing a cold dielectric (CD) type high-Tc superconducting (HTS) power cable. The authors had proposed the electrical insulation design method with concepts of partial discharge-free designs for ac voltage condition. This paper discusses the testing voltages for a 77 kV 1000 A HTS power cable with a length of 500 m, and describes results of various voltage withstand test. As a result, it is concluded that the proposed electrical insulation design method is appropriate for the HTS power cable

  6. Accelerated thermal and radiation-oxidation combined degradation of electric cable insulation materials

    International Nuclear Information System (INIS)

    Yagi, Toshiaki; Seguchi, Tadao; Yoshida, Kenzo

    1986-03-01

    For the development of accelerated testing methodology to estimate the life time of electric cable, which is installed in radiation field such as a nuclear reactor containment vessel, radiation and thermal combined degradation of cable insulation and jacketing materials was studied. The materials were two types of formulated polyethylene, ethylene-propylene rubber, Hypalon, and Neoprene. With Co-60 γ-rays the materials were irradiated up to 0.5 MGy under vacuum and in oxygen under pressure, then exposed to thermal aging at elevated temperature in oxygen. The degradation was investigated by the tensile test, gelfraction, and swelling measurements. The thermal degradation rate for each sample increases with increase of oxygen concentration, i.e. oxygen pressure, during the aging, and tends to saturate above 0.2 MPa of oxygen pressure. Then, the effects of irradiation and the temperature on the thermal degradation rate were investigated at the oxygen pressure of 0.2 MPa in the temperature range from 110 deg C to 150 deg C. For all of samples irradiated in oxygen, the following thermal degradation rate was accelerated by several times comparing with unirradiated samples, while the rate of thermal degradation for the sample except Neoprene irradiated under vacuum was nearly equal to that of unirradiated one. By the analysis of thermal degradation rate against temperature using Arrhenius equation, it was found that the activation energy tends to decrease for the samples irradiated in oxidation condition. (author)

  7. Tracking of Nuclear Cable Insulation Polymer Structural Changes using the Gel Fraction and Uptake Factor Method

    Energy Technology Data Exchange (ETDEWEB)

    Correa, Miguel; Huang, Qian; Fifield, Leonard S.

    2018-04-11

    Cross-linked polyethylene (XLPE) cable insulation samples were exposed to heat and gamma radiation at a series of temperatures, dose rates, and exposure times to evaluate the effects of these variables on material degradation. The samples were tested using the solvent incubation method to collect gel fraction and uptake factor data in order to assess the crosslinking and chain scission occurring in polymer samples with aging. Consistent with previous reports, gel fraction values were observed to increase and uptake factor values to decrease with radiation and thermal exposure. The trends seen were also more prominent as exposure time increased, suggesting this to be a viable method of tracking structural changes in the XLPE-insulated cable material over extended periods. For the conditions explored, the cable insulation material evaluated did not indicate signs of anomalous aging such as inverse temperature effect in which radiation-induced aging is more severe at lower temperature. Ongoing aging under identical radiation conditions and at lower temperature will further inform conclusions regarding the importance of inverse temperature effects for this material under these conditions.

  8. THE EFFICACY OF THE CABLES OF 6–110 KW WITH XLPE INSULATION. Part 2

    Directory of Open Access Journals (Sweden)

    M. A. Korotkevich

    2017-01-01

    Full Text Available The assessment of the suitability of cables of 6–110 kW with XLPE insulation in comparison with cables of the same voltage but possessing paper-oil insulation has been fulfilled on the basis of the method of multi-objective optimization that makes it possible to account not only the quantitative characteristics (of reduced costs, but also qualitative ones. As an indicator of the reliability of the cable line the maximum mean time to failure (the value inversely proportional to the parameter of succession of failures, which is an order more for cable lines with XLPE insulation than for cable lines with paper insulation, is adopted. A comprehensive assessment of the convenience of installation of cable lines revealed that the installation of cable with XLPE insulation features a 1.2–1.6 times easier installation as compared to three-wire (voltage 10 kW and 1.4 times easier installation as compared to single-core oil-filled cables (voltage of 110 kW. The efficacy of the cables 6–110 kW with XLPE insulation is proved on the basis on the method of multi-objective optimization, that took into account as the costs for the construction and operation of cable lines and the reliability of its operation, ease of its installation and other quality indicators. If the goals taken into account are considered as equally important, the polyethylene-insulated cables for a voltage of 10–110 kW is more efficient as compared to three-wire (voltage 10 kW and solid (110 kW cables with paper insulation. Herewith, the cost of the cable with XLPE insulation may exceed the cost of cable with paper insulation up to two times. If the most important aim is to provide the minimum reduced costs for the construction and operation of the cable line, the use of cables with XLPE insulation for voltage of 10 kW is most advisable in individual cases.

  9. Development of superior radiation resistant materials and cables. 2

    Energy Technology Data Exchange (ETDEWEB)

    Ikehara, Junichiro; Kanemitsuya, Kazuhiko; Ohara, Hideo; Araki, Syogo; Hamachi, Katsuhiko [Mitsubishi Cable Industries Ltd., Tokyo (Japan)

    1996-01-01

    Many nuclear power plants have been constructed in Japan and electric power generation is now highly dependent on this technology. Therefore, the needs for facilities that will enrich and reprocess nuclear fuel from nuclear power stations will be high. As there are areas with high levels of radiation, the cables which can be used in these environments are needed. We have developed a superior radiation-resistant cable which uses halogen flame-retardant materials. This radiation-resistant cable consists of Ethylene-propylene rubber (EPDM) insulation and Chlorosulfonated polyethylene (CSM) sheath can be safely used in areas with high levels of radiation. We developed this product to aid in disaster prevention. Non-halogen, flame-retardant EPDM is used for the insulation, and low-halogen, flame-retardant CSM and new non-halogen, flame-retardant materials are used for the sheath. These cables have superior flame-retardant properties and generate little smoke on corrosive gas. This products can hence reduce the danger of a secondary disaster in a fire. We expect that these cables will find application in areas with high levels of radiation. (author).

  10. Development of superior radiation resistant materials and cables. 2

    International Nuclear Information System (INIS)

    Ikehara, Junichiro; Kanemitsuya, Kazuhiko; Ohara, Hideo; Araki, Syogo; Hamachi, Katsuhiko

    1996-01-01

    Many nuclear power plants have been constructed in Japan and electric power generation is now highly dependent on this technology. Therefore, the needs for facilities that will enrich and reprocess nuclear fuel from nuclear power stations will be high. As there are areas with high levels of radiation, the cables which can be used in these environments are needed. We have developed a superior radiation-resistant cable which uses halogen flame-retardant materials. This radiation-resistant cable consists of Ethylene-propylene rubber (EPDM) insulation and Chlorosulfonated polyethylene (CSM) sheath can be safely used in areas with high levels of radiation. We developed this product to aid in disaster prevention. Non-halogen, flame-retardant EPDM is used for the insulation, and low-halogen, flame-retardant CSM and new non-halogen, flame-retardant materials are used for the sheath. These cables have superior flame-retardant properties and generate little smoke on corrosive gas. This products can hence reduce the danger of a secondary disaster in a fire. We expect that these cables will find application in areas with high levels of radiation. (author)

  11. Nuclear power plant cable materials :

    Energy Technology Data Exchange (ETDEWEB)

    Celina, Mathias C.; Gillen, Kenneth T; Lindgren, Eric Richard

    2013-05-01

    A selective literature review was conducted to assess whether currently available accelerated aging and original qualification data could be used to establish operational margins for the continued use of cable insulation and jacketing materials in nuclear power plant environments. The materials are subject to chemical and physical degradation under extended radiationthermal- oxidative conditions. Of particular interest were the circumstances under which existing aging data could be used to predict whether aged materials should pass loss of coolant accident (LOCA) performance requirements. Original LOCA qualification testing usually involved accelerated aging simulations of the 40-year expected ambient aging conditions followed by a LOCA simulation. The accelerated aging simulations were conducted under rapid accelerated aging conditions that did not account for many of the known limitations in accelerated polymer aging and therefore did not correctly simulate actual aging conditions. These highly accelerated aging conditions resulted in insulation materials with mostly inert aging processes as well as jacket materials where oxidative damage dropped quickly away from the air-exposed outside jacket surface. Therefore, for most LOCA performance predictions, testing appears to have relied upon heterogeneous aging behavior with oxidation often limited to the exterior of the cable cross-section a situation which is not comparable with the nearly homogenous oxidative aging that will occur over decades under low dose rate and low temperature plant conditions. The historical aging conditions are therefore insufficient to determine with reasonable confidence the remaining operational margins for these materials. This does not necessarily imply that the existing 40-year-old materials would fail if LOCA conditions occurred, but rather that unambiguous statements about the current aging state and anticipated LOCA performance cannot be provided based on

  12. Chemical oxidation of cable insulating oil contaminated soil

    NARCIS (Netherlands)

    Jinlan Xu,; Pancras, T.; Grotenhuis, J.T.C.

    2011-01-01

    Leaking cable insulating oil is a common source of soil contamination of high-voltage underground electricity cables in many European countries. In situ remediation of these contaminations is very difficult, due to the nature of the contamination and the high concentrations present. Chemical

  13. Development of flame retardant, radiation resistant insulating materials

    Energy Technology Data Exchange (ETDEWEB)

    Hagiwara, M.

    1984-01-01

    On the cables used for nuclear power stations, in particular those ranked as IE class, flame retardation test, simulated LOCA environment test, radiation resistance test and so on are imposed. The results of the evaluation of performance by these tests largely depend on the insulating materials mainly made of polymers. Ethylene propylene copolymer rubber has been widely used as cable insulator because of its electrical characteristics, workability, economy and relatively good radiation resistance, but it is combustible, therefore, in the practical use, it is necessary to make it fire resistant. The author et al. have advanced the research on the molecular design of new fire retarding materials, and successfully developed acenaphthylene bromide condensate, which is not only fire resistant but also effective for improving radiation resistance. The condition of flame retardant, radiation resistant auxiliary agents is explained, and there are additive type and reaction type in fire retarding materials. The synthesis of acenaphthylene bromide condensate and its effect of giving flame retardant and radiation resistant properties are reported. The characteristics of the cables insulated with the flame retardant ethylene propylene rubber containing acenaphthylene bromide condensate were tested, and the results are shown. (Kako, I.).

  14. Tailored sPP/Silica Nanocomposite for Ecofriendly Insulation of Extruded HVDC Cable

    Directory of Open Access Journals (Sweden)

    Bin Dang

    2015-01-01

    Full Text Available Cross-linked polyethylene (XLPE is a thermosetting material that cannot be recycled at the end of its lifetime. This study investigated the potential of syndiotactic polypropylene (sPP/silica as an ecofriendly extruded insulation system for HVDC cables. We investigated the morphology, Fourier transform infrared, and thermal, thermomechanical, and electrical behaviors of sPP modified with 0.5–3% nanosilica. We found that the silica/sPP nanocomposite without cross-linking offered a suitable mechanical modulus at room temperature and sufficient intensity at high temperatures, and adding nanosilica modified by a silane coupling agent to the sPP resulted in significant DC resistivity and space charge improvement. The optimal nanosilica content in the sPP was determined by balancing the mechanical and thermomechanical characteristics and the DC resistivity. The sPP/silica nanocomposite reported here shows great potential as a candidate insulation material for future ecofriendly extruded HVDC cables.

  15. The insulation coordination and surge arrester design for HTS cable system in Icheon substation

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Hansang, E-mail: Hansang80@korea.ac.kr [School of Railway and Electrical Engineering, Kyungil University, Hayang-eup, Gyeongsan-si, Gyeongsangbuk-do 712-701 (Korea, Republic of); Yoon, Dong-Hee [Department of New and Renewable Energy, Kyungil University, Hayang-eup, Gyeongsan-si, Gyeongsangbuk-do 712-701 (Korea, Republic of); Lee, Seung-Ryul [Korea Electrotechnology Research Institute, Naeson-dong, Uiwang-si, Gyeonggi-do 437-080 (Korea, Republic of); Yang, Byeong-Mo [Korea Electric Power Research Institute, Munji-dong, Yuseong-gu, Daejeon 305-760 (Korea, Republic of); Jang, Gilsoo, E-mail: gjang@korea.ac.kr [School of Electrical Engineering, Korea University, Anam-dong 5-ga, Seongbuk-gu, Seoul 136-713 (Korea, Republic of)

    2013-01-15

    Highlights: ► It is necessary to study lightning response of the HTS cable. ► The analytic model has been developed for the HTS cable in the Icheon substation. ► Well-designed surge arrester has been verified through PSCAD/EMTDC simulations. -- Abstract: This paper proposes an insulation coordination and surge arrester design for HTS (High-Temperature Superconducting) cable system in Icheon substation in Korea. In the aspect of the economic analysis, since the HTS cable is very expensive, the insulation coordination to prevent the dielectric breakdown caused by the lightning surge should be considered carefully. Also, in the aspect of the power system reliability, since the HTS cable has much more capacity compared than conventional power cables and the ripple effect from the HTS cable failure may lead to the wide area blackout, an intensive study for insulation coordination from lightning surge is one of the most important considerations. In this paper, the insulation coordination for lightning surge is verified using HTS cable and power equipment models and the design of the proper surge arrester is proposed.

  16. Improvements to the electrical insulation resistance of high quality magnesia insulated cables

    International Nuclear Information System (INIS)

    Mauger, R.A.; Goodings, A.

    1984-03-01

    Mineral insulated signal cables for nuclear reactor instrumentation schemes have to meet stringent electrical insulation requirements at high temperatures. This report discusses the factors which influence the attainment of this objective and the way in which it has been reached under industrial manufacturing conditions. It emphasises the importance of moisture and gives details of the improvements achieved as a result of moisture reduction. (author)

  17. Investigations of a mechanically failed cable insulation used in indoor conditions

    CERN Document Server

    Setnescu, R; Lungulescu, E M; Ilie, S; Marinescu, V; Mares, G; Setnescu, T

    2011-01-01

    This paper presents the investigation work on different polymeric materials used as insulation materials of conductors in a multicore instrumentation cable. Among differently colored materials, only the white one presented cracks after a few years of use. Isothermal and non-isothermal DSC measurements were performed on initial (non-used) and aged (in service used or laboratory aged) materials as well as on raw materials in order to characterize their stability and the ageing state after storage, use in service or laboratory ageing. As shown by the oxidation induction time values, a pronounced antioxidant loss occurred for all materials during storage or service; plus a strong effect of the ambient light on stability was observed for the white insulation material. Around 3\\% of filler, consisting mainly of TiO(2) particles (as revealed by SEM-XRF elemental analysis), was found in the white material. The higher degradability of the white material can be related to both the photocatalytic effect of the TiO(2) pa...

  18. Radiation resistance of cable insulation and jacket materials for nuclear power plants

    International Nuclear Information System (INIS)

    Morita, Minoru; Kon, Shuji; Nishikawa, Ichiro

    1978-01-01

    The cables for use in nuclear power plants are required to satisfy the specific environmental resistance and excellent flame resistance as stipulated in IEEE Std. 383. The materials to be used to cables intended for this specific purpose of use must therefore be strictly tested so as to evaluate their flame resistance in addition to compliance with various environmental requirements, such as heat resistance, water-vapor resistance, and radiation resistance. This paper describes general information on radiation resistance and deterioration of various high-molecular materials, suggests the direction of efforts to be made to improve their properties including flame resistance of various rubber and plastic materials for cables to be used in nuclear power plants, and indicates the performance characteristics of such materials. (author)

  19. Research on material of high temperature cable and wire insulation by γ-rays

    International Nuclear Information System (INIS)

    Jia Shaojin; Zhang Zhicheng; Xu Xiangling; Ge Xuewu; Ye qiang; Wang Feng

    2000-01-01

    Radiation-crosslinking improves a number of essential properties of polymers, so the high -temperature-resistance of polyethylene (PE) was increased by irradiation. The national products of High -density-polyethylene (HDPE), crosslinking promoters, flame-retardant, antioxidants, Si rubber, and Ethylene-propylene-monomer (EPDM) were used as cable insulation. After -irradiation, thermal-endurance can get above 135, and high flame retardance was firmed, Oxygen index can get above 32 by crosslinking

  20. Influence of LOCA simulating conditions on the variation of electrical characteristics of insulating materials

    Energy Technology Data Exchange (ETDEWEB)

    Okada, Sohei; Yoshikawa, Masato; Ito, Masayuki; Kusama, Yasuo; Yagi, Toshiaki

    1982-12-01

    The authors have examined the variation of insulation resistance when the sheets of insulating materials and cables were exposed to various LOCA simulating environment. This report describes the summarized results obtained so far for ethylene propylene rubber (EPR) which is important as an insulating material of cables. The samples used were an EPR sheet of standard compound ratio, 2 kinds of EPR sheets of practical compound ratio, 6 types of PH cables (fire-retardant, EPR insulated, chlorosulphonated polyethylene sheathed cable) produced for trial as reactor use, and 6 kinds of EPR sheets of the same composition as the cable core. To discuss the difference of insulation resistance change, the logarithmic mean of the ratio of 1 min values to initial insulation resistance rho/rhosub(o) was used. PWR LOCA-simulating environment was used, while the thermal aging in the air at 121 deg C for 7 days and 50 Mrad irradiation in the air at room temperature were given as the predeterioration. The effect of LOCA-simulation period in the simultaneous method without air, in which steam and radiation were given in parallel, the difference in the experimental results of cables and sheets, the effect of air, the comparison of the simultaneous method with the sequential method in which LOCA-simulating steam was applied after the irradiation in the air and the reverse sequential method (dielectric property measurements) are described. Under the existence of air, the sequential method seems to be a good simulation condition for the simultaneous method, though many experiments are required further.

  1. Influence of LOCA simulating conditions on the variation of electrical characteristics of insulating materials

    International Nuclear Information System (INIS)

    Okada, Sohei; Yoshikawa, Masato; Ito, Masayuki; Kusama, Yasuo; Yagi, Toshiaki

    1982-01-01

    The authors have examined the variation of insulation resistance when the sheets of insulating materials and cables were exposed to various LOCA simulating environment. This report describes the summarized results obtained so far for ethylene propylene rubber (EPR) which is important as an insulating material of cables. The samples used were an EPR sheet of standard compound ratio, 2 kinds of EPR sheets of practical compound ratio, 6 types of PH cables (fire-retardant, EPR insulated, chlorosulphonated polyethylene sheathed cable) produced for trial as reactor use, and 6 kinds of EPR sheets of the same composition as the cable core. To discuss the difference of insulation resistance change, the logarithmic mean of the ratio of 1 min values to initial insulation resistance rho/rhosub(o) was used. PWR LOCA-simulating environment was used, while the thermal aging in the air at 121 deg C for 7 days and 50 Mrad irradiation in the air at room temperature were given as the predeterioration. The effect of LOCA-simulation period in the simultaneous method without air, in which steam and radiation were given in parallel, the difference in the experimental results of cables and sheets, the effect of air, the comparison of the simultaneous method with the sequential method in which LOCA-simulating steam was applied after the irradiation in the air and the reverse sequential method (dielectric property measurements) are described. Under the existence of air, the sequential method seems to be a good simulation condition for the simultaneous method, though many experiments are required further. (Wakatsuki, Y.)

  2. Mineral insulated cables for post accident service

    International Nuclear Information System (INIS)

    McMillin, P.L.; Winkler, M.E.

    1986-01-01

    The regulatory requirement to measure the gamma radiation levels during accident conditions inside a reactor containment building is discussed. The development of a mineral-insulated cable and connector system to accurately transmit this measurement is described and a model of the response is developed

  3. Study of the degradation of the insulation of HV cables with PVC insulation

    International Nuclear Information System (INIS)

    Quennehen, Pierre

    2014-01-01

    The observed decrease in the resistivity of the PVC insulation of some high voltage unipolar cables led to question their ability to perform their function. Provide answers concerning in particular the origin of the variation in resistivity and the impact on the dielectric strength were the objectives of this study. The characterizations were carried on cables withdrawn from service whose properties had changed during their use. Physico-chemical characterization (IR microscopy, UV spectroscopy, SEM - EDX and coulometry) showed that aging of the cable resulted from a mechanism of dehydro-chlorination. The presence of two modes of electric conduction in the material was observed: electronic conduction at a low temperature (≤ -10 C) and ionic conduction at room temperature and beyond. The presence of these two modes of conduction is consistent with the mechanism of dehydro-chlorination. In contrast to an Arrhenius law, artificial aging showed a threshold effect in the thermal activation of the mechanism at the origin of the resistivity drop. The dielectric strength of the cable has been confirmed by tests at voltages or temperatures well beyond the nominal values. Measurements of differential scanning calorimetry (DSC) showed occasional more or less pronounced over-heatings that correlate with the resistivity drops, and can therefore be considered as being at the origin of the observed evolutions. (author)

  4. Tailored sPP/Silica Nano composite for Eco friendly Insulation of Extruded HVDC Cable

    International Nuclear Information System (INIS)

    Dang, B.; He, J.; Hu, J.; Zhou, Y.

    2015-01-01

    Cross-linked polyethylene (XLPE) is a thermosetting material that cannot be recycled at the end of its lifetime. This study investigated the potential of syndiotactic polypropylene (sPP)/silica as an eco friendly extruded insulation system for HVDC cables. We investigated the morphology, Fourier transform infrared, and thermal, thermomechanical, and electrical behaviors of sPP modified with 0.5-3% nano silica. We found that the silica/sPP nano composite without cross-linking offered a suitable mechanical modulus at room temperature and sufficient intensity at high temperatures, and adding nano silica modified by a silane coupling agent to the sPP resulted in significant DC resistivity and space charge improvement. The optimal nano silica content in the sPP was determined by balancing the mechanical and thermomechanical characteristics and the DC resistivity. The sPP/silica nano composite reported here shows great potential as a candidate insulation material for future eco friendly extruded HVDC cables.

  5. Effect that radiation exerts to insulation breakdown of heat resistant polymer materials

    International Nuclear Information System (INIS)

    Fujita, Shigetaka; Baba, Makoto; Noto, Fumitoshi; Ruike, Mitsuo.

    1990-01-01

    Artificial satellites are always exposed to cosmic rays which contain the radiations which do not reach the ground, therefore, the radiation resistance of the polymer insulators for cables and others used in such environment becomes a problem. Also the polymer insulator materials used for nuclear facilities require excellent radiation resistance. It is important to examine the effect that radiation exerts to electric insulation characteristics from the viewpoint of material development. In this paper, the insulation breakdown characteristics of heat resistant polymer films and the mini-cables made for trial of heat resistant polymer materials in the case without irradiation and in the case of gamma ray irradiation, and the results of the structural analysis are reported. The specimens tested, the experimental method and the results are described. The insulation breakdown strength of PFA and FEP films lowered from 0.15-0.2 MGy, but that of PEEK film did not change up to 5 MGy. It was found that fluorine group resins were apt to deteriorate by oxidation as dose increased. (K.I.)

  6. Influence of water trees on breakdown voltage of polymeric cables insulations

    Energy Technology Data Exchange (ETDEWEB)

    Stancu, Cristina [INCDIE ICPE CA, Bucharest (Romania); Notingher, Petru V.; Plopeanu, Mihai Gabriel [Politehnica University of Bucharest, Bucharest (Romania)

    2011-07-01

    In a previous paper was shown that water trees development modifies considerably the electric field repartition, which increases significantly in the vicinity of treed areas. In order to find the water trees influence on the breakdown voltage, in the present paper, an experimental study on model cables insulated with low density polyethylene is done. In insulation samples, water trees with various dimensions and densities were developed. For the reduction of the test duration, an electric field with a higher frequency (3-5 kHz) was used. For breakdown voltage measurement an automatic setup was realized. For each value of the ageing time the dimensions and densities of water trees and breakdown voltage were measured and the dependency of the breakdown voltage with these quantities were analysed. The results show a significant reduction of the breakdown voltage of treed cables insulations compared to un-treed ones. Key words: polyethylene, water treeing, electric field, breakdown, power cables.

  7. Problems with conductors and dielectrics for cryogenic cables

    Energy Technology Data Exchange (ETDEWEB)

    Bogner, G; Penczynski, P [Siemens A.G., Erlangen (F.R. Germany). Abt. Reaktortechnik

    1976-06-01

    The most important problems which need to be solved if superconducting power cables are to be used on a large scale are connected with the superconducting cable materials and the dielectrics used for insulation. Research work on superconducting materials for ac and dc cables is briefly reviewed together with stabilization problems for these materials. Three types of insulation are considered - vacuum, subcooled or supercritical helium, and foil wound insulation. The merits and problems encountered in each case are discussed.

  8. Material Selection for Cable Gland to Improved Reliability of the High-hazard Industries

    Science.gov (United States)

    Vashchuk, S. P.; Slobodyan, S. M.; Deeva, V. S.; Vashchuk, D. S.

    2018-01-01

    The sealed cable glands (SCG) are available to ensure safest connection sheathed single wire for the hazard production facility (nuclear power plant and others) the same as pilot cable, control cables, radio-frequency cables et al. In this paper, we investigate the specifics of the material selection of SCG with the express aim of hazardous man-made facility. We discuss the safe working conditions for cable glands. The research indicates the sintering powdered metals cables provide the reliability growth due to their properties. A number of studies have demonstrated the verification of material selection. On the face of it, we make findings indicating that double glazed sealed units could enhance reliability. We had evaluated sample reliability under fire conditions, seismic load, and pressure containment failure. We used the samples mineral insulated thermocouple cable.

  9. Effect of moisture on the electrical performance of transition-joints for medium voltage paper-insulated cables; Elektrische Beeintraechtigung durch Feuchtigkeit an oelgetraenkten Isolierpapieren. Mittelspannungsuebergangsmuffen

    Energy Technology Data Exchange (ETDEWEB)

    Cardinaels, Jos [Nexans Network Solution, Erembodegem (Belgium). Produktentwicklung; Baesch, Manfred [Nexans Power Accessories Germany, Dortmund (Germany). Produkt- und Qualitaetsmanagement

    2009-06-15

    Paper-insulated cables are constructed with an impervious metallic outer jacket in order to protect them against ingress of moisture. On 'modern' transition-joints to XLPE-insulated cables, this metal barrier is interrupted, hence, a risk of moisture penetration exists. This text presents measurements of water-vapour permeability of used materials and discusses the results of ageing tests. (orig.)

  10. Nonlinear Dielectric Response of Water Treed XLPE Cable Insulation

    Energy Technology Data Exchange (ETDEWEB)

    Hvidsten, Sverre

    1999-07-01

    Condition assessment of XLPE power cables is becoming increasingly important for the utilities, due to a large number of old cables in service with high probability of failure caused by water tree degradation. The commercial available techniques are generally based upon measurements of the dielectric response, either by time (polarisation/depolarisation current or return voltage) or frequency domain measurements. Recently it has been found that a high number of water trees in XLPE insulated cables causes the dielectric response to increase more than linearly with increasing test voltage. This nonlinear feature of water tree degraded XLPE insulation has been suggested to be of a great importance, both for diagnostic purposes, and for fundamental understanding of the water tree phenomenon itself. The main purpose of this thesis have been to study the nonlinear feature of the dielectric response measured on watertreed XLPE insulation. This has been performed by dielectric response measurements in both time and frequency domain, numerical calculations of losses of simplified water tree models, and fmally water content and water permeation measurements on single water trees. The dielectric response measurements were performed on service aged cable samples and laboratory aged Rogowski type objects. The main reason for performing laboratory ageing was to facilitate diagnostic testing as a function of ageing time of samples containing mainly vented water trees. A new method, based upon inserting NaC1 particles at the interface between the upper semiconductive screen and the insulation, was found to successfully enhance initiation and growth of vented water trees. AC breakdown strength testing show that it is the vented water trees that reduce the breakdown level of both the laboratory aged test objects and service aged cable samples. Vented water treeing was found to cause the dielectric response to become nonlinear at a relatively low voltage level. However, the measured

  11. Optimization of electron beam crosslinking of wire and cable insulation

    International Nuclear Information System (INIS)

    Zimek, Zbigniew; Przybytniak, Grażyna; Nowicki, Andrzej

    2012-01-01

    The computer simulations based on Monte Carlo (MC) method and the ModeCEB software were carried out in connection with electron beam (EB) radiation set-up for crosslinking of electric wire and cable insulation. The theoretical predictions for absorbed dose distribution in irradiated electric insulation induced by scanned EB were compared to the experimental results of irradiation that was carried out in the experimental set-up based on ILU 6 electron accelerator with electron energy 0.5–2.0 MeV. The computer simulation of the dose distributions in two-sided irradiation system by a scanned electron beam in multilayer circular objects was performed for various process parameters, namely electric wire and cable geometry (thickness of insulation layers and copper wire diameter), type of polymer insulation, electron energy, energy spread and geometry of electron beam, electric wire and cable layout in irradiation zone. The geometry of electron beam distribution in the irradiation zone was measured using CTA and PVC foil dosimeters for available electron energy range. The temperature rise of the irradiated electric wire and irradiation homogeneity were evaluated for different experimental conditions to optimize technological process parameters. The results of computer simulation are consistent with the experimental data of dose distribution evaluated by gel-fraction measurements. Such conformity indicates that ModeCEB computer simulation is reliable and sufficient for optimization absorbed dose distribution in the multi-layer circular objects irradiated with scanned electron beams. - Highlights: ► We model wire and cables irradiation process by Monte Carlo simulations. ► We optimize irradiation configuration for various process parameters. ► Temperature rise and irradiation homogeneity were evaluated. ► Calculation (dose) and experimental (gel-fraction) results were compared. ► Computer simulation was found reliable and sufficient for process optimization.

  12. Research on vacuum insulation for cryocables

    International Nuclear Information System (INIS)

    Graneau, P.

    1974-01-01

    Vacuum insulation, as compared with solid insulation, simplifies the construction of both resistive or superconducting cryogenic cables. The common vacuum space in the cable can furnish thermal insulation between the environment and the cryogenic coolant, provide electrical insulation between conductors, and establish thermal isolation between go- and return-coolant streams. The differences between solid and vacuum high voltage insulation are discussed, and research on the design, materials selection, and testing of vacuum insulated cryogenic cables is described

  13. Study of heat transfer in superconducting cable electrical insulation of accelerator magnet cooled by superfluid helium; Etude des transferts de chaleur dans les isolations electriques de cables supraconducteurs d'aimant d'accelerateur refroidi par helium superfluide

    Energy Technology Data Exchange (ETDEWEB)

    Baudouy, B

    1996-10-04

    Heat transfer studies of electrical cable insulation in superconducting winding are of major importance for stability studies in superconducting magnets. This work presents an experimental heat transfer study in superconducting cables of Large Hadron Collider dipoles cooled by superfluid helium and submitted to volume heat dissipation due to beam losses. For NbTi magnets cooled by superfluid helium the most severe heat barrier comes from the electrical insulation of the cables. Heat behaviour of a winding is approached through an experimental model in which insulation characteristics can be modified. Different tests on insulation patterns show that heat transfer is influenced by superfluid helium contained in insulation even for small volume of helium (2 % of cable volume). Electrical insulation can be considered as a composite material made of a solid matrix with a helium channels network which cannot be modelled easily. This network is characterised by another experimental apparatus which allows to study transverse and steady-state heat transfer through an elementary insulation pattern. Measurements in Landau regime ({delta}T{approx}10{sup -5} to 10{sup -3} K) and in Gorter-Mellink regime ({delta}T>10{sup -3} K) and using assumptions that helium thermal paths and conduction in the insulation are decoupled allow to determine an equivalent channel area (10{sup -6} m{sup 2}) and an equivalent channel diameter (25 {mu}). (author)

  14. Time domain spectroscopy to monitor the condition of cable insulation

    International Nuclear Information System (INIS)

    Mopsik, F.I.; Martzloff, F.D.

    1989-01-01

    The use of Time Domain Spectroscopy, the measurement of dielectric constant and loss using time-domain response, the monitoring the aging of reactor cable insulation is examined. The method is presented, showing its sensitivity, accuracy and wide frequency range. The method's ability to acquire a great deal of information in a short time and its superiority to conventional single frequency data is shown. Different cable samples are examined before and after exposure to radiation and changes with exposure are clearly seen to occur. Also it is shown that a wide range of behavior can be found in different insulation systems. The requirements for performing valid measurements is presented. The need for controlled samples and correlation with other criteria for aging is discussed. 14 refs., 9 figs

  15. Protection for low current superconducting coils wound with insulated strand cable

    International Nuclear Information System (INIS)

    Satti, J.

    1980-09-01

    The insulated strand cable concept for winding of low current superconducting coil leads to an ideal quench protection by induction coupling. A superconducting secondary loop was made within a cable of a 6.2 Henry dipole coil. When quenching occurred, current was induced in the secondary strand above the critical value. The normal strand quenched the whole cable due to good thermal contact. The secondary loop works as a heater turned on as the wire becomes normal throughout the coil. With a well spread quench, the energy dissipation density is decreased thus preventing local burnout. The mechanism is possible because of close coupling that is present in the insulated cable as in bifilar winding. For the coil tested a 12 strand cable was used, thus a favorable 11 to 1 turn ratio was obtained for the primary to secondary. The superconductor in the secondary had a lower resistance until the critical current was achieved. A theoretical explanation is described for a simplified circuit. Test on the dipole coil with four individual shells showed that the one shell protected with the induced coupling heater always had a more rapid reduction of current. The induced coupling heater tested and explained in this paper works automatically and does not rely on mechanical or electrical devices

  16. Ceramic insulation for superconducting Nb{sub 3}Sn cables; Isolation ceramique pour cables supraconducteurs en Nb{sub 3}Sn

    Energy Technology Data Exchange (ETDEWEB)

    Puigsegur, A

    2005-01-15

    Nb{sub 3}Sn is the best superconductor candidate for the realization of high field magnets (>11 Tesla), its implementation remains delicate because of the great brittleness of material after the heat treatment necessary to the formation of Nb{sub 3}Sn compounds. The conventional insulation for Nb{sub 3}Sn requires to perform, after the heat treatment, a vacuum resin impregnation, which adds to the cost and raises failure risk. We have proposed an innovating ceramic insulation deposited directly on the unreacted conducting cable. After the heat treatment of the niobium tin, we obtain a coil having a mechanical cohesion, while maintaining a proper conductor positioning and a suitable electric insulation. After a rheological study, to characterize the impregnated suspension, we have shown that using this insulation in a coil manufacture process does not affect the electrical properties of the Nb{sub 3}Sn wires. A solenoid of small dimensions was tested with success in high external magnetic fields and has produced a magnetic field of 3.8 T under 740 A. (author)

  17. Study of heat transfer in superconducting cable electrical insulation of accelerator magnet cooled by superfluid helium; Etude des transferts de chaleur dans les isolations electriques de cables supraconducteurs d'aimant d'accelerateur refroidi par helium superfluide

    Energy Technology Data Exchange (ETDEWEB)

    Baudouy, B

    1996-10-04

    Heat transfer studies of electrical cable insulation in superconducting winding are of major importance for stability studies in superconducting magnets. This work presents an experimental heat transfer study in superconducting cables of Large Hadron Collider dipoles cooled by superfluid helium and submitted to volume heat dissipation due to beam losses. For NbTi magnets cooled by superfluid helium the most severe heat barrier comes from the electrical insulation of the cables. Heat behaviour of a winding is approached through an experimental model in which insulation characteristics can be modified. Different tests on insulation patterns show that heat transfer is influenced by superfluid helium contained in insulation even for small volume of helium (2 % of cable volume). Electrical insulation can be considered as a composite material made of a solid matrix with a helium channels network which cannot be modelled easily. This network is characterised by another experimental apparatus which allows to study transverse and steady-state heat transfer through an elementary insulation pattern. Measurements in Landau regime ({delta}T{approx}10{sup -5} to 10{sup -3} K) and in Gorter-Mellink regime ({delta}T>10{sup -3} K) and using assumptions that helium thermal paths and conduction in the insulation are decoupled allow to determine an equivalent channel area (10{sup -6} m{sup 2}) and an equivalent channel diameter (25 {mu}). (author)

  18. Effect of air on speed of insulating material deterioration under simulated LOCA environment. [Gamma radiation

    Energy Technology Data Exchange (ETDEWEB)

    Kusama, Yasuo; Yagi, Toshiaki; Ito, Masayuki; Okada, Sohei; Yoshikawa, Masato (Japan Atomic Energy Research Inst., Takasaki, Gunma. Takasaki Radiation Chemistry Research Establishment)

    1982-12-01

    To examine the quality approval testing method for the electric cables used for nuclear reactors, various covering insulating materials employed for the cables have been investigated from all angles. The factors which are considered to affect the deterioration of cable materials in a simulated LOCA (loss of coolant accident) environmental test are numerous. This paper reports on the result of investigation on the effect of air on the rate of deterioration of various organic materials usually used as the insulating and covering materials for the cables. Five kinds of polymer sheets (1 mm thick) used for reactor cables were employed as samples. The samples of both standard compounding ratio and the compounding ratio for practical reactor use were tested. As the deterioration prior to LOCA simulation, the thermal deterioration corresponding to 40 years aging (at 121 deg C for 7 days) was given, and subsequently, 50 Mrad gamma -irradiation at 1 Mrad/h was performed in the air. After that, the samples were subject to LOCA simulated environment. Since the results were different according to the kinds of samples, those are described separately for Hypalon, ethylene propylene rubber, cross-linked polyethylene, chloroprene and silicone rubber. The existence of air under LOCA environment accelerated the deterioration of insulation materials except silicone rubber, though its influence differed to the polymers. These materials swelled in the presence of air, and the degree of swelling increased with the temperature, having the close relation to oxidation deterioration. Polyethylene was more susceptible to the effect of air, and silicone rubber was rather stable. The samples of fire-retardant compounding ratio more swelled by water absorption than those of standard compounding ratio.

  19. 30 CFR 7.407 - Test for flame resistance of electric cables and cable splices.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Test for flame resistance of electric cables... Electric Cables, Signaling Cables, and Cable Splice Kits § 7.407 Test for flame resistance of electric... material and 21/2 inches of conductor insulation. The type, amperage, voltage rating, and construction of...

  20. A Study of the Equality of Cable Insulations by comparing aging trend using an Oxidation Induction Time Measurement Test

    International Nuclear Information System (INIS)

    Park, Kyungheum; Bhang, Keugjin; Jeong, Sunchul

    2014-01-01

    Usually, the environmental qualification test is carried out by the cable manufacturer and the test report is presented while the cable manufacturer supplies the tested cables in nuclear power plant. If a cable manufacturer has environmentally qualified a cable for nuclear power plant more than a decade ago and the composition of the cable material is same, is it acceptable to use the old EQ report for recently manufactured cable? Even though the manufacturer insists the composition of the tested cable and recently manufactured cable's material are same, there can some questions or opposing opinions for two cables, tested cable and recently manufactured cable's equality. In this case, how can I determine the equality for the two cables? It is well known method to use FT-IR to determine the similarity of cable materials. FT-IR is easy tool to compare compositions of each material. But FT-IR method is not proper to compare aging trend of these materials. Oxidation induction time(OIT) testing is a technique that can be used to evaluate aging of organic materials and life assessment technique for cables used in nuclear power plants. In this paper, I studied the OIT technique to compare aging trend for the tested cable and recently manufactured cable to determine the equality for the two cables. To study a equality analysis for cable materials, OIT measurement tests were performed for two cable insulation(produced in 1995 and produced in 2013) which were supplied from same manufacturer. The two cables were irradiated up to 40 Mrad to simulate normal 40 years and thermally aged for 144 hours at 170 .deg. C equals to 40 years qualified life at 90 .deg. C. The OIT measurement were made in order to compare aging trends of the '95 cable and the '13 cable, the test were performed for three sequential steps; initial, after Normal Radiation and after Thermal Aging. The OIT measurement results at the temperature of 225 .deg. C showed very similar degradation

  1. Cable Insulation Breakdowns in the Modulator with a Switch Mode High Voltage Power Supply

    CERN Document Server

    Cours, A

    2004-01-01

    The Advanced Photon Source modulators are PFN-type pulsers with 40 kV switch mode charging power supplies (PSs). The PS and the PFN are connected to each other by 18 feet of high-voltage (HV) cable. Another HV cable connects two separate parts of the PFN. The cables are standard 75 kV x-ray cables. All four cable connectors were designed by the PS manufacturer. Both cables were operating at the same voltage level (about 35 kV). The PS’s output connector has never failed during five years of operation. One of the other three connectors failed approximately five times more often than the others. In order to resolve the failure problem, a transient analysis was performed for all connectors. It was found that transient voltage in the connector that failed most often was subjected to more high-frequency, high-amplitude AC components than the other three connectors. It was thought that these components caused partial discharge in the connector insulation and led to the insulation breakdown. Modification o...

  2. Suppression of discharge breakdown of polyethylene insulation during electron beam irradiation to power cable

    International Nuclear Information System (INIS)

    Sasaki, T.; Hosoi, F.; Kasai, N.; Hagiwara, M.

    1981-01-01

    In an attempt to apply the electron beam process to the crosslinking procedure for polyethylene insulation of high tension power cables, the suppression of discharge breakdown during irradiation has been investigated in the presence of crosslinking agents. Alkylamines of strong basicity and secondary or tertiary alcoholamines were found to be effective additives to suppress the discharge breakdown. The retardation of crosslinking by amines was minimized by reducing the amount of an amine and adding an alcohol instead. Polyethylene compounds contaning crosslinking agents, amines and alcohols which gave properties suitable for insulating a cable were obtained. The feasibility of these results are ascertained by irradiating cable specimens of a 22 kV class. (author)

  3. Evaluation of diagnostic technique for degradation of low-voltage electric cables with silicone rubber insulator

    International Nuclear Information System (INIS)

    Mikami, Masao

    2005-01-01

    As a part of countermeasures against ageing problems of nuclear power plants, it is requested to establish non-destructive diagnostic technique for their degradation of low voltage electric cables and assessment standard of their life. Having aimed at investigating the degradation of low-voltage electric cable with silicone rubber insulator, change of its surface hardness at elevated temperature were measured by indenter modules. Moreover, we also measured the elongation at break, which is regarded as general degradation index of electric cables, and the surface hardness with a micro hardness meter. Consequently, it is seen that the indenter modulus measurement is (1) capable to obtain general feature of the thermal degradation of silicone rubber insulator, (2) applicable to diagnose the degree of degradation of the electric cable by converting the result to elongation at break, (3) well correlated with the hardness measurement of the electric cable with the micro hardness meter. (author)

  4. Steady-state heat transfer in He II through porous superconducting cable insulation

    International Nuclear Information System (INIS)

    Baudouy, B.J.P.; Juster, F.P.; Meuris, C.; Vieillard, L.

    1996-01-01

    The LHC program includes the study of thermal behavior of the superconducting cables wound in the dipole magnet cooled by superfluid helium (He II). Insulation of these superconducting cables forms the major thermal shield hindering the He II cooling. This is particularly a problem in magnets which are subjected to thermal loads. To investigate He II heat transfer processes an experimental model has been realized which creates a one-dimensional heat transfer in such media. Insulation is generally realized by wrapping around the superconducting cable a combination of different kind of Kapton reg-sign tapes, fiber-glass impregnated by epoxy resin or Kevlar reg-sign fiber tapes. Steady-state heat transfer in He II through these multi-layer porous slabs has been analyzed. Experimental results for a range of heat flux show the existence of different thermal regimes related to He II. It is shown that the parameters of importance are a global geometrical factor which could be considered as an equivalent open-quotes permeabilityclose quotes related to He II heat transfer, the transfer function f(T) of He II and the thermal conductivity of the slab. The authors present and analyze results for different insulations as a function of the temperature

  5. Corrosion of mineral insulated (MI) cables at MAPS-2

    International Nuclear Information System (INIS)

    Bora, J.S.; Babar, A.K.

    1989-01-01

    It has been experimentally verified that the cause of undesirable behaviour of mineral insulated (MI) cables at Madras Atomic Power Station Unit 2 (MAPS-2) is due to corrosion of termination. It is always possible to restore them to their normal condition by heating if degradation is due to absorption of moisture and by cutting and removing the affected portion in case of short or open failures. During extended shutdown, it is advisable to check other MI terminations and take appropriate corrective action in order to prevent failures in future. During installation MI Cables are to be heated before sealing and should never be heated after sealing. (author)

  6. Research on FR-HDPE/EPDM for cable and wire insulation by γ rays

    International Nuclear Information System (INIS)

    Jia Shaojin; Zhang Zhicheng; Ge Xuewu; Du Zhiwen; Wang Zhenzhou

    2002-01-01

    By blending low-halogen flame-retarding agent with the basic resin and using γ irradiation FR-HDPE/EPDM for cable and wire insulation with 125 degree C heat resistance was prepared. The mechanical and electrical measurement showed that radiation crosslinking improves some essential properties of the material, such as the heat resistance, tensile strength et al. The dynamic flammability of the material was researched by cone calorimeter, it was found that radiation crosslinking decreases both release heat rate and effective heat of combustion while burning, besides, crosslinking increases oxygen index and the residues of combustion though the time to ignition of the irradiated material is somewhat decreased. The work was compared with the traditional method TG measurement

  7. A new cable-in-conduit conductor magnet with insulated strands

    International Nuclear Information System (INIS)

    Yamaguchi, Satarou; Yamamoto, Junya; Motojima, Osamu.

    1995-09-01

    Many studies have used cable-in-conduit conductor (CICC) coils in trying to develop an AC superconducting magnet because of its enormous potential if AC losses were low and insulation voltage was high. The strands in the most recent CICC magnets are coated with chromium or another metal with high electrical resistance to order to induce current re-distribution among the strands and to avoid a quench caused by a current imbalance. Current re-distribution is highly complex and very difficult to analyze because the conditions of the strand surfaces and the contact areas vary greatly with the operation of the conductor. If, however, the cable currents were well-balanced, insulating the strands would be the best way to reduce AC losses. We propose a new CICC magnet structure featuring a current lead that balances the strand currents via its resistance. Having calculated current balances, we find that strand currents are well within the present parameters for nuclear fusion experiments and superconducting magnet energy storages. (author)

  8. Life estimation I and C cable insulation materials based on accelerated life testing accelerated life testing

    International Nuclear Information System (INIS)

    Santhosh, T.V.; Ramteke, P.K.; Shrestha, N.B.; Ahirwar, A.K.; Gopika, V.

    2016-01-01

    Accelerated Iife tests are becoming increasingly popular in today's industry due to the need for obtaining life data quickly and reliably. Life testing of products under higher stress levels without introducing additional failure modes can provide significant savings of both time and money. Correct analysis of data gathered via such accelerated life testing will yield parameters and other information for the product's life under use stress conditions. To be of practical use in assessing the operational behaviour of cables in NPPs, laboratory ageing aims to mimic the type of degradation observed under operational conditions. Conditions of testing therefore need to be carefully chosen to ensure that the degradation mechanism occurring in the accelerated tests are similar to those which occur in service. This paper presents the results of an investigation in which the elongation-at-break (EAB) measurements were carried on a typical control cable to predict the mean life at service conditions. A low voltage polyvinyl chloride (PVC) insulated and PVC sheathed control cable, used in NPP instrumentation and control (I and C) applications, was subjected thermal ageing at three elevated temperatures

  9. Optimization of electron beam crosslinking of wire and cable insulation

    International Nuclear Information System (INIS)

    Zimek, Z.; Przybytniak, G.; Nowicki, A.

    2011-01-01

    Complete text of publication follows. The computer simulations based on Monte Carlo method and the ModeCEB software program were carried out in connection with EB radiation set-up for crosslinking of electrical wire and cable insulation, located at the Center for Radiation Research and Technology of the Institute of Nuclear Chemistry and Technology. The theoretical predictions for absorbed dose distribution in irradiated electrical wire and cable insulation caused by scanned EB were compared to the experimental results of irradiation which were carried out in the experimental set-up based on ILU 6 electron accelerator, which is characterized by the following parameters: Electron energy 0.5-2.0 MeV; Average beam current 40-10 mA, pulse duration 400 μs; Width of scanning up to 80 cm; Scan frequency up to 50 Hz. The computer simulation of the dose distributions in two-sided irradiation system by a scanned electron beam in multilayer circular objects was performed for different process parameters; electrical wire and cable geometry (thickness of insulation layers and cupper wire diameter), type of polymer isolation, electron energy, energy spread, geometry of electron beam and electrical wire and cable distribution at irradiation zone. The geometry of electron beam distribution in irradiation zone was measured using TVA and PVC foil dosimeters for electron energy range available in ILU 6 accelerator. The temperature rise of irradiated electrical wire and irradiation homogeneity were evaluated for different experimental conditions to optimize process parameters. The obtained results of computer simulation were supported by experimental data of dose distribution based on gel-fraction measurements. Such agreement indicates that computer simulation ModeCEB is correct and sufficient for modelling of absorbed dose distribution in multi-layer circular objects irradiated with scanned electron beams. Acknowledgement: The R and D activities are supported by the European

  10. Ageing of instrumentation and control cables in NPPs

    International Nuclear Information System (INIS)

    Santhosh; Ghosh, A.K.; Fernandes, B.G.

    2011-01-01

    Cables are vital components of instrumentation and control (I and C) systems in nuclear power plants (NPPs). The polymer materials used for insulation and jacket materials for electric cables are susceptible to ageing and degradation mechanisms caused by exposure to many of the stressors encountered in NPP service conditions. Ageing of components in NPP is an important concern since the degradation caused by ageing can impact the performance of susceptible equipment. This is of particular concern for safety-related equipment since the failure due to ageing can compromise the continued safe operation of the plant. The state-of-the art for incorporating cable ageing effects into probabilistic safety assessment (PSA) is still evolving and in the reliability assessment of NPP systems, the ageing effect of electrical cable is generally not considered and also, there is no standard method exists for incorporating such ageing effects into the system reliability. Therefore, identification and quantification of ageing of electrical cables is very much essential for an accurate prediction of system reliability for PSA applications. The objective of this study is to develop a methodology to assess the susceptibility of polymeric cable insulation to various ageing mechanisms; and the state of the insulation at any chosen time in order to evaluate the remaining life-time of operating cables in NPPs. This paper presents the state-of-the-art tools and techniques for insulation condition assessment, insulation life prediction methodologies, equipment qualification guidelines, and ageing management programs relating to I and C cables in NPPs. An approach to calculate the insulation resistance subjecting to different stressors has also been presented in this paper. (author)

  11. Current redistribution in cables made of insulated, soldered, or oxidized strands

    International Nuclear Information System (INIS)

    Turck, B.

    1979-07-01

    Current redistributions are compared in cables made of insulated strands, soldered, or oxidized strands and insulated strands with periodic joints. After discussing the different current redistributions in the cases of a rapidly changing current and a dc current, several particular situations are investigated: what happens if a strand is broken, or if a local normal zone appears that does not affect all the strands equally, the detection of this normal zone, and the influence of short circuits between strands

  12. Heat-shrinkable splicing materials for Class 1E wire and cable systems in nuclear power generating stations

    International Nuclear Information System (INIS)

    Handa, Katsue; Maruyama, Masahiro; Kanno, Mikio; Ohya, Shingo; Nagakawa, Seiji; Sugimori, Mikihiro

    1987-01-01

    This report describes the shapes of heat-shrinkable splicing materials (cable sleeve and breakout, and round end cap) made of polyolefine resin, their application to cable splicing, and the properties of the materials as well as of the splice using them. Particularly, the report features introduction of their properties as determined by tests under the same conditions as used in Japan in qualifying tests on wires and cables for nuclear power generating stations. The heat-shrinkable splicing materials proved to be equal in properties to flame-retardant cables for nuclear power plants when tested for oxygen index and subjected to a vertical flame test on ''insulated wire'' and a vertical tray flame test on the cable splice. It was also confirmed that Class 1E cable using these splicing materials could stand the most rigorous environmental test in Japan. Therefore they can be used for splicing Class 1E wires and cables and the splice formed with them can be regarded as Class 1E specified in IEEE Std. 383. (author)

  13. New, clean handling process introduced to improve cable quality

    Energy Technology Data Exchange (ETDEWEB)

    Hunt, C G

    1990-05-01

    The clean room system introduced by Canada Wire and Cable Limited in its Toronto plant for its cable manufacturing operation is described. While clean room technology is common in the food processing industry, optical and aerospace manufacturing processes, this is the first time it has been applied to wire and cable extrusion in North America. The purpose of the clean compound handling system is to prevent particle contamination in the shielding and cable insulation materials, as part of an effort to prevent premature underground electric cable failures. Two rooms are dedicated to handling different types of insulation compound, two are dedicated to receiving semi-conducting shielding material, and the fifth room functions as an air lock for the two insulation rooms. The atmosphere is highly regulated with programmable logic control. The air supply filters capture 99.97% of all particles 0.3 microns or larger. The system also maintains air temperature, relative humidity and static pressure. The life variability of cross-linked polyethylene primary distribution cable is dependant on five factors: material purity, extra clean compound handling, cable design, manufacturing process, and installation and operation practices. The clean room system is expected to result in cable that is more resistant to water treeing failures. 2 figs.

  14. New piercing for insulated cables in underground networks; Novos conectores compactos perfurantes ('piercings') para cabos isoldados em redes subterraneas

    Energy Technology Data Exchange (ETDEWEB)

    Moreno, Fernando; Corral, Horacio [Tradis, SP (Brazil). E-mail: tradis@mandic.com.br

    1999-07-01

    This work presents a tap and transition connection in low voltage protected underground cables. This connection allows tapping for clients or branchings from a main energized cables. The compact connectors range various types of insulated cables protected and under grounded in a simple way. The work analysed the advantages of using two components polyurethane resins for the tapping protection and insulation restoring.

  15. Nuclear instrumentation cable end seal

    International Nuclear Information System (INIS)

    Cannon, C.P.; Brown, D.P.

    1979-01-01

    An improved coaxial end seal for hermetically sealed nuclear instrumentation cable exhibiting an improved breakdown pulse noise characteristic under high voltage, high temperature conditions is described. A tubular insulator body has metallized interior and exterior surface portions which are braze sealed to a center conductor and an outer conductive sheath. The end surface of the insulator body which is directed toward the coaxial cable to which it is sealed has a recessed surface portion within which the braze seal material terminates

  16. Effect of radiation resistance additives for insulation materials

    International Nuclear Information System (INIS)

    Yamamoto, Yasuaki; Yagyu, Hideki; Seguchi, Tadao.

    1988-01-01

    For the electric wires and cables used in radiation environment such as nuclear power stations and fuel reprocessing facilities, the properties of excellent radiation resistance are required. For these insulators and sheath materials, ethylene propylene rubber, polyethylene and other polymers have been used, but it cannot be said that they always have good radiation resistance. However, it has been well known that radiation resistance can be improved with small amount of additives, and heat resistance and burning retarding property as well as radiation resistance are given to the insulators of wires and cables for nuclear facilities by mixing various additives. In this research, the measuring method for quantitatively determining the effect of Anti-rad (radiation resistant additive) was examined. Through the measurement of gel fraction, radical formation and decomposed gas generation, the effect of Anti-rad protecting polymers from radiation deterioration was examined from the viewpoint of chemical reaction. The experimental method and the results are reported. The radiation energy for cutting C-H coupling is polymers is dispersed by Anti-rad, and the probability of cutting is lowered. Anti-rad catches and extinguishes radicals that start oxidation reaction. (K.I.)

  17. VPE single core medium voltage cables in EVU supply networks. [Polyethylene (VPE)

    Energy Technology Data Exchange (ETDEWEB)

    Reuter, E [Elektromark Kommunales Elektrizitaetswerk Mark A.G., Hagen (Germany, F.R.). Elektrotechnische Abt.

    1977-02-01

    This paper gives a brief outline of the different cable constructions and constructional parts of medium voltage cables (10 - 20 kV) in power supply networks. At medium voltage (particularly at 20 kV), single core cables are being used to an increasing extent, preferably for station supplies and for pole mounted cables. Polymerized polyethylene (VPE) is used as insulating material for this cable; according to present knowledge it is suitable for the insulation of power cables for all voltages up to 110 kV.

  18. Investigation of the sensitivity of MIS-sensor to thermal decomposition products of cables insulation

    Science.gov (United States)

    Filipchuk, D. V.; Litvinov, A. V.; Etrekova, M. O.; Nozdrya, D. A.

    2017-12-01

    Sensitivity of the MIS-sensor to products of thermal decomposition of insulation and jacket of the most common types of cables is investigated. It is shown that hydrogen is evolved under heating the insulation to temperatures not exceeding 250 °C. Registration of the evolved hydrogen by the MIS-sensor can be used for detection of fires at an early stage.

  19. Cable Diagnostic Focused Initiative

    Energy Technology Data Exchange (ETDEWEB)

    Hartlein, R.A.; Hampton, R.N.

    2010-12-30

    This report summarizes an extensive effort made to understand how to effectively use the various diagnostic technologies to establish the condition of medium voltage underground cable circuits. These circuits make up an extensive portion of the electric delivery infrastructure in the United States. Much of this infrastructure is old and experiencing unacceptable failure rates. By deploying efficient diagnostic testing programs, electric utilities can replace or repair circuits that are about to fail, providing an optimal approach to improving electric system reliability. This is an intrinsically complex topic. Underground cable systems are not homogeneous. Cable circuits often contain multiple branches with different cable designs and a range of insulation materials. In addition, each insulation material ages differently as a function of time, temperature and operating environment. To complicate matters further, there are a wide variety of diagnostic technologies available for assessing the condition of cable circuits with a diversity of claims about the effectiveness of each approach. As a result, the benefits of deploying cable diagnostic testing programs have been difficult to establish, leading many utilities to avoid the their use altogether. This project was designed to help address these issues. The information provided is the result of a collaborative effort between Georgia Tech NEETRAC staff, Georgia Tech academic faculty, electric utility industry participants, as well as cable system diagnostic testing service providers and test equipment providers. Report topics include: •How cable systems age and fail, •The various technologies available for detecting potential failure sites, •The advantages and disadvantages of different diagnostic technologies, •Different approaches for utilities to employ cable system diagnostics. The primary deliverables of this project are this report, a Cable Diagnostic Handbook (a subset of this report) and an online

  20. Behaviour at thermal ageing of power cable components through penetrations

    International Nuclear Information System (INIS)

    Puiu, D.; Gyongyosi, T.; Dinu, E.

    2009-01-01

    The materials for electric insulation and exterior jackets of the power cables are formulated organic compounds. The environmental service conditions will induce chemical and/or physical processes at molecular level of the material; these processes are the ageing mechanisms. The power cables passing through penetrations lead to an increase of the rate of thermal ageing mechanisms, resulting in irreversible degradation of mechanical and electric properties of the organic compounds and of the functional properties of the cable. The paper presents the results of the laboratory tests when the real environmental service conditions for penetration are simulated, the comparison with the results of the thermal computation of the power cables heating and the evaluation of the influence of temperature increase of the power cable components on the cable lifetime. For the particular case of a power cable with PVC insulation, we estimated a lifetime decrease about seven years as referred to lifetime of about 30 years for operation in air. (authors)

  1. Application of mineral insulated cable (MIC) in Tokamak fusion reactor

    International Nuclear Information System (INIS)

    Luo Tianyong; Jiang Jiaming; Cen Yishun

    2014-01-01

    To avoid the instability of plasma and achieve some experimental tasks in Tokamak fusion reactor, many in-vessel coils are designed such as the coils to mitigate the effect of Edge Localized Modes (ELMs coils) and the coils to provide vertical stabilization (VS coils). The in-vessel location presents special challenges in terms of nuclear radiation and temperature, and requires the use of mineral-insulated conductors. The in-vessel coils in ITER are designed to be Mineral-insulated Cable (MIC) with three-layer structures. The inner is hollow-core tube made by OFHC or CuCrZr, the middle is the insulation layer made by Mgo and the outer is the jacket by SS316L or Inconel 718. To control the effect of Edge Localized Modes and vertical instability of plasma, the MIC in-vessel coils shall be used in HL-2M. More details about the application of MIC in Tokamak fusion reactor will be shown in this report. (authors)

  2. Bulk Electrical Cable Non-Destructive Examination Methods for Nuclear Power Plant Cable Aging Management Programs

    Energy Technology Data Exchange (ETDEWEB)

    Glass, Samuel W. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Jones, Anthony M. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Fifield, Leonard S. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Hartman, Trenton S. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States)

    2016-09-01

    This Pacific Northwest National Laboratory milestone report describes progress to date on the investigation of nondestructive test methods focusing particularly on bulk electrical test methods that provide key indicators of cable aging and damage. The work includes a review of relevant literature as well as hands-on experimental verification of inspection capabilities. As nuclear power plants consider applying for second, or subsequent, license renewal to extend their operating period from 60 years to 80 years, it is important to understand how the materials installed in plant systems and components will age during that time and develop aging management programs to assure continued safe operation under normal and design basis events (DBE). Normal component and system tests typically confirm the cables can perform their normal operational function. The focus of the cable test program, however, is directed toward the more demanding challenge of assuring the cable function under accident or DBE. The industry has adopted 50% elongation at break (EAB) relative to the un-aged cable condition as the acceptability standard. All tests are benchmarked against the cable EAB test. EAB, however, is a destructive test so the test programs must apply an array of other nondestructive examination (NDE) tests to assure or infer the overall set of cable’s system integrity. Assessment of cable integrity is further complicated in many cases by vendor’s use of dissimilar material for jacket and insulation. Frequently the jacket will degrade more rapidly than the underlying insulation. Although this can serve as an early alert to cable damage, direct test of the cable insulation without violating the protective jacket becomes problematic. This report addresses the range of bulk electrical NDE cable tests that are or could be practically implemented in a field-test situation with a particular focus on frequency domain reflectometry (FDR). The FDR test method offers numerous advantages

  3. Preparation and Dielectric Properties of SiC/LSR Nanocomposites for Insulation of High Voltage Direct Current Cable Accessories.

    Science.gov (United States)

    Shang, Nanqiang; Chen, Qingguo; Wei, Xinzhe

    2018-03-08

    The conductivity mismatch in the composite insulation of high voltage direct current (HVDC) cable accessories causes electric field distribution distortion and even insulation breakdown. Therefore, a liquid silicone rubber (LSR) filled with SiC nanoparticles is prepared for the insulation of cable accessories. The micro-morphology of the SiC/LSR nanocomposites is observed by scanning electron microscopy, and their trap parameters are characterized using thermal stimulated current (TSC) tests. Moreover, the dielectric properties of SiC/LSR nanocomposites with different SiC concentrations are tested. The results show that the 3 wt % SiC/LSR sample has the best nonlinear conductivity, more than one order of magnitude higher than that of pure LSR with improved temperature and nonlinear conductivity coefficients. The relative permittivity increased 0.2 and dielectric loss factor increased 0.003, while its breakdown strength decreased 5 kV/mm compared to those of pure LSR. Moreover, the TSC results indicate the introduction of SiC nanoparticles reduced the trap level and trap density. Furthermore, the SiC nanoparticles filling significantly increased the sensitivity of LSR to electric field stress and temperature changes, enhancing the conductivity and electric field distribution within the HVDC cable accessories, thus improving the reliability of the HVDC cable accessories.

  4. Status Report and Research Plan for Cables Harvested from Crystal River Unit 3 Nuclear Generating Plant

    Energy Technology Data Exchange (ETDEWEB)

    Fifield, Leonard S. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States)

    2016-09-20

    Harvested cables from operating or decommissioned nuclear power plants present an important opportunity to validate models, understanding material aging behavior, and validate characterization techniques. Crystal River Unit 3 Nuclear Generating Plant is a pressurized water reactor that was licensed to operate from 1976 to 2013. Cable segments were harvested and made available to the Light Water Reactor Sustainability research program through the Electric Power Research Institute. Information on the locations and circuits within the reactor from whence the cable segments came, cable construction, sourcing and installation information, and photographs of the cable locations prior to harvesting were provided. The cable variations provided represent six of the ten most common cable insulations in the nuclear industry and experienced service usage for periods from 15 to 42 years. Subsequently, these cables constitute a valuable asset for research to understand aging behavior and measurement of nuclear cables. Received cables harvested from Crystal River Unit 3 Nuclear Generating Plant consist of low voltage, insulated conductor surrounded by jackets in lengths from 24 to 100 feet each. Cable materials will primarily be used to investigate aging under simultaneous thermal and gamma radiation exposure. Each cable insulation and jacket material will be characterized in its as-received condition, including determination of the temperatures associated with endothermic transitions in the material using differential scanning calorimetry and dynamic mechanical analysis. Temperatures for additional thermal exposure aging will be selected following the thermal analysis to avoid transitions in accelerated laboratory aging that do not occur in field conditions. Aging temperatures above thermal transitions may also be targeted to investigate the potential for artifacts in lifetime prediction from rapid accelerated aging. Total gamma doses and dose rates targeted for each material

  5. ASSESSMENT OF CABLE AGING USING CONDITION MONITORING TECHNIQUES

    International Nuclear Information System (INIS)

    GROVE, E.; LOFARO, R.; SOO, P.; VILLARAN, M.; HSU, F.

    2000-01-01

    Electric cables in nuclear power plants suffer degradation during service as a result of the thermal and radiation environments in which they are installed. Instrumentation and control cables are one type of cable that provide an important role in reactor safety. Should the polymeric cable insulation material become embrittled and cracked during service, or during a loss-of-coolant-accident (LOCA) and when steam and high radiation conditions are anticipated, failure could occur and prevent the cables from fulfilling their intended safety function(s). A research program is being conducted at Brookhaven National Laboratory to evaluate condition monitoring (CM) techniques for estimating the amount of cable degradation experienced during in-plant service. The objectives of this program are to assess the ability of the cables to perform under a simulated LOCA without losing their ability to function effectively, and to identify CM techniques which may be used to determine the effective lifetime of cables. The cable insulation materials tested include ethylene propylene rubber (EPR) and cross-linked polyethylene (XLPE). Accelerated aging (thermal and radiation) to the equivalent of 40 years of service was performed, followed by exposure to simulated LOCA conditions. The effectiveness of chemical, electrical, and mechanical condition monitoring techniques are being evaluated. Results indicate that several of these methods can detect changes in material parameters with increasing age. However, each has its limitations, and a combination of methods may provide an effective means for trending cable degradation in order to assess the remaining life of cables

  6. Digital computers' cable replacement at the Hydro-Quebec Gentilly 2 nuclear power station

    International Nuclear Information System (INIS)

    Gour, N.; Rivest, J.-M.

    1992-01-01

    During the 1990 annual outage of Gentilly-2, inspection of the digital control computers revealed signs of degradation in about 20% of the cable connector assemblies. This raised concern of increased risk of signal failure by short circuit. The degradation of the insulation was traced to a material incompatibility problem originating during manufacture of the cables. Migration of the plasticizer contained in the PVC of the transparent sheaths surrounding many of the conductors resulted in chemical attack on the insulation. All the cable assemblies were replaced during 1991-1992. The new cable assemblies were manufactured using the Raychem process, which lacked the faulty material. Also, the opportunity was taken to modify the ground network while the computer systems were stripped of their main components. Although the work cost over C$900,000, nevertheless planning and execution were nearly flawless, and the project a complete success. Integrity of cable insulation should not be a concern for the rest of the plant's life. 5 refs

  7. Insulated Wire Fed Floating Monopole Antenna for Coastal Monitoring

    Directory of Open Access Journals (Sweden)

    Z. M. Loni

    2018-04-01

    Full Text Available A thin, flexible, insulated wire submerged in seawater forms a coaxial cable which has attenuation at ultra-high frequency (UHF dependent on the operating frequency, the diameter of the insulating material and the diameter of the inner conductor. An extension of the insulated wire above the surface through a spherical float forms a monopole antenna. Attenuation through the wire depends on the conductivity and temperature of seawater. This paper reports the effect of electromagnetic (EM wave propagation at 433 MHz through insulated wires with different radii of the insulating material and inner conductor. The attenuation was calculated and measured in the range of 32-47 dB/m. The propagation from the monopole antenna to a fixed shore based receiver was measured to be approximately equal to 1 dB/m. The propagation measurements were compared with a shielded coaxial cable. Results show that the propagation range depends on the ratio of the insulation radius to conductor radius for insulated wire, however, a shielded coaxial cable showed no significant attenuation. The technique has applications in coastal wireless sensor networks where the water depth changes continually due to tide and wave motion.

  8. Microstructural characterization of XLPE electrical insulation in power cables: determination of void size distributions using TEM

    International Nuclear Information System (INIS)

    Markey, L; Stevens, G C

    2003-01-01

    In an effort to progress in our understanding of the ageing mechanisms of high voltage cables submitted to electrical and thermal stresses, we present a quantitative study of voids, the defects which are considered to be partly responsible for cable failure. We propose a method based on large data sets of transmission electron microscopy (TEM) observations of replicated samples allowing for the determination of void concentration distribution as a function of void size in the mesoscopic to microscopic range at any point in the cable insulation. A theory is also developed to calculate the effect of etching on the apparent size of the voids observed. We present the first results of this sort ever obtained on two industrial cables, one of which was aged in an AC field. Results clearly indicate that a much larger concentration of voids occur near the inner semiconductor compared to the bulk of the insulation, independently of ageing. An effect of ageing can also be seen near the inner semiconductor, resulting in an increase in the total void internal surface area and a slight shift of the concentration curve towards larger voids, with the peak moving from about 40 nm to about 50 nm

  9. Finite Element Modeling in 3D of the Impact of Superfluid Helium Filled Micro-channels on the Heat Transfer through LHC Type Cable Insulation

    CERN Document Server

    Bielert, E; ten Kate, H

    2012-01-01

    For a future luminosity upgrade of CERN’s Large Hadron Collider, a drastically improved heat removal in the inner triplet quadrupole magnets is required. One of the necessary improvements involves the cable insulation. A porous all-polyimide insulation scheme has been proposed recently. Essentially the insulation features a network of micro channels filled with superfluid helium that significantly increases the heat transfer through the insulation layer. A three dimensional Finite Element model required to simulate and study the enhanced heat transfer through the micro channels is presented here. The thermal coupling between heated cable and helium as well as the heat flux through the micro-channels are investigated. The model is validated by comparison of results with published measured data. Finally a sensitivity analysis is performed concerning the stability of the cables in magnet windings.

  10. Instrumentation Cables Test Plan

    Energy Technology Data Exchange (ETDEWEB)

    Muna, Alice Baca [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); LaFleur, Chris Bensdotter [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2016-10-01

    A fire at a nuclear power plant (NPP) has the potential to damage structures, systems, and components important to safety, if not promptly detected and suppressed. At Browns Ferry Nuclear Power Plant on March 22, 1975, a fire in the reactor building damaged electrical power and control systems. Damage to instrumentation cables impeded the function of both normal and standby reactor coolant systems, and degraded the operators’ plant monitoring capability. This event resulted in additional NRC involvement with utilities to ensure that NPPs are properly protected from fire as intended by the NRC principle design criteria (i.e., general design criteria 3, Fire Protection). Current guidance and methods for both deterministic and performance based approaches typically make conservative (bounding) assumptions regarding the fire-induced failure modes of instrumentation cables and those failure modes effects on component and system response. Numerous fire testing programs have been conducted in the past to evaluate the failure modes and effects of electrical cables exposed to severe thermal conditions. However, that testing has primarily focused on control circuits with only a limited number of tests performed on instrumentation circuits. In 2001, the Nuclear Energy Institute (NEI) and the Electric Power Research Institute (EPRI) conducted a series of cable fire tests designed to address specific aspects of the cable failure and circuit fault issues of concern1. The NRC was invited to observe and participate in that program. The NRC sponsored Sandia National Laboratories to support this participation, whom among other things, added a 4-20 mA instrumentation circuit and instrumentation cabling to six of the tests. Although limited, one insight drawn from those instrumentation circuits tests was that the failure characteristics appeared to depend on the cable insulation material. The results showed that for thermoset insulated cables, the instrument reading tended to drift

  11. Cables for nuclear power generating stations, (6)

    International Nuclear Information System (INIS)

    Kakuta, Tsunemi; Asakawa, Naoki; Yamamoto, Tomotaka; Watanabe, Mikio; Shingo, Yoshioki.

    1981-01-01

    New inorganic material insulated flexible triaxial cables have been developed for the purpose of applying around the primary circuit of fast breeder reactor (FBR). These cables were tested at high temperature and high #betta#-ray radiation environment, and they showed good electrical properties. Other noted results were that they showed good fire proof and flame resistant properties. (author)

  12. Development of low-smoke, flame-retarding cables

    International Nuclear Information System (INIS)

    Kato, H.; Kanemitsuya, K.; Furukawa, K.; Mio, K.

    1983-01-01

    A great deal of attention has been given to the potential fire hazard of combustion gases from organic materials. Although cable industries have developed flame-retarding organic materials for the insulation and jacketing of wires and cables, there was insufficient prevention of toxic gas formation during combustion. To cope with these problems associated with conventional PVC cables, the authors have directed to develop low-smoke, flame-retarding plasticized PVC formulations retaining the original mechanical, electrical and aging properties. A series of basic investigations on smoke suppression followed by an evaluation on practical cables could indicate some effective means to end these problems. This paper describes the results and discussion on smoke suppressing study of plasticized PVC as well as behavior and characteristics of the low-smoke, flame-retarding PVC wires and cables using these materials. (author)

  13. Dynamic Test Method Based on Strong Electromagnetic Pulse for Electromagnetic Shielding Materials with Field-Induced Insulator-Conductor Phase Transition

    Science.gov (United States)

    Wang, Yun; Zhao, Min; Wang, Qingguo

    2018-01-01

    In order to measure the pulse shielding performance of materials with the characteristic of field-induced insulator-conductor phase transition when materials are used for electromagnetic shielding, a dynamic test method was proposed based on a coaxial fixture. Experiment system was built by square pulse source, coaxial cable, coaxial fixture, attenuator, and oscilloscope and insulating components. S11 parameter of the test system was obtained, which suggested that the working frequency ranges from 300 KHz to 7.36 GHz. Insulating performance is good enough to avoid discharge between conductors when material samples is exposed in the strong electromagnetic pulse field up to 831 kV/m. This method is suitable for materials with annular shape, certain thickness and the characteristic of field-induced insulator-conductor phase transition to get their shielding performances of strong electromagnetic pulse.

  14. Development of a method of partial discharge detection in extra-high voltage cross-linked polyethylene insulated cable lines

    International Nuclear Information System (INIS)

    Katsuta, G.; Toya, A.; Muraoka, K.; Endoh, T.; Sekii, Y.; Ikeda, C.

    1992-01-01

    This paper reports that deterioration in the insulation performance of extra-high voltage XLPE cables is believed to be attributable to the deterioration caused by partial discharges. In the authors study, after using an XLPE cable to investigate the behavior of partial discharges under various adverse conditions, we succeeded in developing a highly sensitive new method of measuring partial discharge in XLPE cable lines. Partial discharges in a 275 kV XLPE cable live line has been measured using this newly developed method. As a result, a detection sensitivity of 1 pC has been achieved

  15. Effect of antioxidants on aging of nuclear plant cable insulation

    International Nuclear Information System (INIS)

    Reynolds, A.B.; Ray, J.W.; Wlodkowski, P.A.

    1991-01-01

    The effects of various antioxidants and antioxidant concentrations on the radiation and thermal stability of EPDM and XLPE polymers used for insulation of electric cable in nuclear power plants were measured. The objective was to determine if particular antioxidants could be identified as being especially effective for stabilization against radiation aging and combined thermal and radiation aging. Elongation to rupture was used as the measure of stability. Materials were irradiated to doses up to 2 MGy (200 Mrad) at a dose rate of 200 to 300 Gy/h in the Cobalt-60 Gamma Irradiation Facility at the University of Virginia. All of the antioxidants tested, which were known to provide excellent thermal stability, also provided good stability for radiation aging and combined thermal/radiation aging, although small differences between antioxidants were noted. No antioxidant or antioxidant combination was identified as being especially outstanding. Stabilization against radiation increased with increasing antioxidant concentration, but this trend was not observed for thermal aging. Damage from thermal and radiation aging was superposable. 9 refs., 16 figs., 12 tabs

  16. Heat transfer through the flat surface of Rutherford superconducting cable samples with novel pattern of electrical insulation immersed in He II

    Science.gov (United States)

    Strychalski, M.; Chorowski, M.; Polinski, J.

    2014-05-01

    Future accelerator magnets will be exposed to heat loads that exceed even by an order of magnitude presently observed heat fluxes transferred to superconducting magnet coils. To avoid the resistive transition of the superconducting cables, the efficiency of heat transfer between the magnet structure and the helium must be significantly increased. This can be achieved through the use of novel concepts of the cable’s electrical insulation wrapping, characterized by an enhanced permeability to helium while retaining sufficient electrical resistivity. This paper presents measurement results of the heat transfer through Rutherford NbTi cable samples immersed in a He II bath and subjected to the pressure loads simulating the counteracting of the Lorentz forces observed in powered magnets. The Rutherford cable samples that were tested used different electrical insulation wrapping schemes, including the scheme that is presently used and the proposed scheme for future LHC magnets. A new porous polyimide cable insulation with enhanced helium permeability was proposed in order to improve the evacuation of heat form the NbTi coil to He II bath. These tests were performed in a dedicated Claudet-type cryostat in pressurized He II at 1.9 K and 1 bar.

  17. Evaluation of the indenter modulus (IM) method in the international round robin test about the cable condition monitoring

    International Nuclear Information System (INIS)

    Kajimura, Yuusaku

    2016-01-01

    In order to ensure the reliability and safety of nuclear power plants, the diagnosis of cable aging is important. The Institute of Nuclear Safety System (INSS) has been developing the indenter modulus (IM) method for more than a dozen years. Its usefulness was demonstrated in the research project 'Assessment of cable aging for nuclear power plant' by the Japan Nuclear Energy Safety Organization in 2009. Furthermore, INSS participated in the IAEA Coordinated Research Project in 2013 to 2015, measuring and acquiring data of insulation materials of cables and cable jackets with insulation which had been never measured before by INSS. The main results are as follows. (1) The IM method is useful for new materials (for example, crosslinked polyolefins) which had never been measured before by INSS. (2) The IM method is also applicable to evaluation of cable jackets with insulation made of such materials as chlorosulfonated polyethylene. Therefore, the IM method is evaluated to be useful and applicable for most cable materials except those which have a high IM value initially and which have a small change in IM value during aging. (author)

  18. Cable aging tests

    International Nuclear Information System (INIS)

    Hubbard, G.

    1993-01-01

    This paper describes the results from aging, condition monitoring, and loss-of-coolant accident (LOCA) testing of class 1E electrical cables, per NUREG/CR-5772. This test was designed to test the performance of cables which had been aged with simultaneous radiation and thermal exposure. The tested cables included crosslinked polyolefin cables, ethylene propylene rubber cables, and miscellaneous cable types. Cables were exposed to 20, 40, and 60 years equivalent aging, and then exposed to LOCA tests at the end of their qualified life to determine the minimum insulation thickness needed for survival of the test. Failures were found in a large number of the tested cables. As a result the NRC has sent information notices to the industry regarding potential insulation problems. The results have raised the question of whether the artificial aging methods provide adequate testing methods. As a result of this testing the NRC is reviewing the artificial aging procedures, the adequacy of environmental qualification requirements for cable safety, and reexamining data from condition monitoring of installed cables

  19. Results of Recent DOE Research on Development of Cable Condition Monitoring and Aging Management Technologies

    International Nuclear Information System (INIS)

    Campbell, C.J.; McConkey, J.B.; Hashemian, H.M.; Sexton, C.D.; Cummins, D.S.

    2012-01-01

    Analysis and Measurement Services (AMS) Corporation has been conducting two research projects focused on understanding cable aging and developing cable condition monitoring technologies for nuclear power plants. The goal of the first project is to correlate cable faults with testing techniques that can identify and locate the faults whether they are in the cable, conductor, or the insulation. This project involves laboratory experiments using low and medium voltage cable types typically installed in nuclear power plants. The second project is focused on development of an integrated cable condition monitoring system for nuclear facilities. This system integrates a number of cable testing and cable condition monitoring techniques, such as the time domain reflectometry (TDR), frequency domain reflectometry (FDR), inductance, capacitance, resistance (LCR), reverse TDR (RTDR), current-to-voltage (IV) for testing of nuclear instrumentation sensors, insulation resistance (IR) and other techniques. The purpose of the project is to combine all proven technologies into one system to detect and pinpoint problems in cable circuits as well as cable insulation, shield, or jacket material. (author)

  20. Power plant cable condition monitoring and testing at Georgia Power

    International Nuclear Information System (INIS)

    Champion, T.C.

    1988-01-01

    Georgia Power's Research Center has been heavily involved in the evaluation of electrical insulating materials and cables since its inception more than 17 years ago. For the past ten years that expertise has been applied to cables used in generation plants. This paper discusses the results of two test programs. The first is a quality control inspection on 169 samples of new power generation cables. The second is a material degradation evaluation on four short cable samples removed from a coal fired plant during an equipment upgrade. The new material evaluation was performed to identify the cause of a high failure rate upon initial hi-pot testing of newly installed cables. The material degradation evaluation was performed to evaluate the need for replacement of existing cables during an equipment upgrade. Results of the evaluations have led to development of a detailed proposal for a program to evaluate cable degradation and remaining life for cables used in power generation facilities

  1. Cable aging management

    International Nuclear Information System (INIS)

    Anandkumaran, A.; Sedding, H.

    2012-01-01

    prerequisite for terminal electrical measurements. Instead, condition assessment of low voltage cables is based on chemical analysis of the materials that comprise the cable insulation and jacket. This contribution will discuss in detail the electrical, chemical and mechanical methods that have been employed in Canadian nuclear plants as well as the experience gained over the last 25 years. (author)

  2. Studying radiolytic ageing of nuclear power plant electric cables with FTIR spectroscopy.

    Science.gov (United States)

    Levet, A; Colombani, J; Duponchel, L

    2017-09-01

    Due to the willingness to extend the nuclear power plants length of life, it is of prime importance to understand long term ageing effect on all constitutive materials. For this purpose gamma-irradiation effects on insulation of instrumentation and control cables are studied. Mid-infrared spectroscopy and principal components analysis (PCA) were used to highlight molecular modifications induced by gamma-irradiation under oxidizing conditions. In order to be closer to real world conditions, a low dose rate of 11Gyh -1 was used to irradiate insulations in full cable or alone with a dose up to 58 kGy. Spectral differences according to irradiation dose were extracted using PCA. It was then possible to observe different behaviors of the insulation constitutive compounds i.e. ethylene vinyl acetate (EVA), ethylene propylene diene monomer (EPDM) and aluminium trihydrate (ATH). Irradiation of insulations led to the oxidation of their constitutive polymers and a modification of filler-polymer ratio. Moreover all these modifications were observed for insulations alone or in full cable indicating that oxygen easily diffuses into the material. Spectral contributions were discussed considering different degradation mechanisms. Copyright © 2017 Elsevier B.V. All rights reserved.

  3. Response of Nuclear Power Plant Instrumentation Cables Exposed to Fire Conditions.

    Energy Technology Data Exchange (ETDEWEB)

    Muna, Alice Baca [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); LaFleur, Chris Bensdotter [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Brooks, Dusty Marie [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2017-09-01

    This report presents the results of instrumentation cable tests sponsored by the US Nuclear Regulatory Commission (NRC) Office of Nuclear Regulatory Research and performed at Sandia National Laboratories (SNL). The goal of the tests was to assess thermal and electrical response behavior under fire-exposure conditions for instrumentation cables and circuits. The test objective was to assess how severe radiant heating conditions surrounding an instrumentation cable affect current or voltage signals in an instrumentation circuit. A total of thirty-nine small-scale tests were conducted. Ten different instrumentation cables were tested, ranging from one conductor to eight-twisted pairs. Because the focus of the tests was thermoset (TS) cables, only two of the ten cables had thermoplastic (TP) insulation and jacket material and the remaining eight cables were one of three different TS insulation and jacket material. Two instrumentation cables from previous cable fire testing were included, one TS and one TP. Three test circuits were used to simulate instrumentation circuits present in nuclear power plants: a 4–20 mA current loop, a 10–50 mA current loop and a 1–5 VDC voltage loop. A regression analysis was conducted to determine key variables affecting signal leakage time.

  4. A New Contribution in Reducing Electric Field Distribution Within/Around Medium Voltage Underground Cable Terminations

    Directory of Open Access Journals (Sweden)

    S. S. Desouky

    2017-10-01

    Full Text Available Ιn medium voltage cables, the stress control layers play an important part in controlling the electric field distribution around the medium voltage underground cable terminations. Underground cable accessories, used in medium voltage cable systems, need a stress control tube in order to maintain and control the insulation level which is designed for long life times. The term “electrical stress control” refers to the cable termination analysis of optimizing the electrical stress in the area of insulation shield cutback to reduce the electrical field concentration at this point in order to reduce breakdown in the cable insulation. This paper presents the effect of some materials of different relative permittivities and geometrical regulation with the curved shape stress relief cones on the electric field distribution of cable termination. The optimization was done by comparing the results of eight materials used. Also, the effect of the change in the thickness of the stress control tube is presented. The modeling design is very important for engineers to find the optimal solution of terminator design of medium voltage cables. This paper also describes the evolution of stress control systems and their benefits. A developed program using Finite Element Method (FEM has calculated a numerical study to the stress control layering electric field distribution.

  5. Normal zone propagation characteristics of coated conductor according to insulation materials

    International Nuclear Information System (INIS)

    Yang, S.E.; Ahn, M.C.; Park, D.K.; Chang, K.S.; Bae, D.K.; Ko, T.K.

    2007-01-01

    Recent development of CC, usually called second generation (2G) HTS, is actively in progress. Because of its higher critical current density as well as higher n-value, 2G HTS is feasible for the applications such as superconducting fault current limiter and superconducting cable. For operating the HTS equipment stably, it needs to investigate the characteristics of normal zone propagation occurred by quench. Investigations on the fundamental characteristics can be one of the indispensable foundations for research and development of power equipments. In this paper, normal zone propagation (NZP) characteristics according to various insulation materials are researched. By heating with NiCr heater and insulating with epoxy, we applied the operating current with respect to the critical current for calculation of minimum quench energy (MQE) and measurement of NZP

  6. Morphology and crystalline-phase-dependent electrical insulating properties in tailored polypropylene for HVDC cables

    Science.gov (United States)

    Zha, Jun-Wei; Yan, Hong-Da; Li, Wei-Kang; Dang, Zhi-Min

    2016-11-01

    Polypropylene (PP) has become one promising material to potentially replace the cross-link polyethylene used for high voltage direct current cables. Besides the isotactic polypropylene, the block polypropylene (b-PP) and random polypropylene (r-PP) can be synthesized through the copolymerization of ethylene and propylene molecules. In this letter, the effect of morphology and crystalline phases on the insulating electrical properties of PP was investigated. It was found that the introduction of polyethylene monomer resulted in the formation of β and γ phases in b-PP and r-PP. The results from the characteristic trap energy levels indicated that the β and γ phases could induce deep electron traps which enable to capture the carriers. And the space charge accumulation was obviously suppressed. Besides, the decreased electrical conductivity was observed in b-PP and r-PP. It is attributed to the existence of deep traps which can effectively reduce the carrier mobility and density in materials.

  7. The Role of Interfaces in Polyethylene/Metal-Oxide Nanocomposites for Ultrahigh-Voltage Insulating Materials.

    Science.gov (United States)

    Pourrahimi, Amir Masoud; Olsson, Richard T; Hedenqvist, Mikael S

    2018-01-01

    Recent progress in the development of polyethylene/metal-oxide nanocomposites for extruded high-voltage direct-current (HVDC) cables with ultrahigh electric insulation properties is presented. This is a promising technology with the potential of raising the upper voltage limit in today's underground/submarine cables, based on pristine polyethylene, to levels where the loss of energy during electric power transmission becomes low enough to ensure intercontinental electric power transmission. The development of HVDC insulating materials together with the impact of the interface between the particles and the polymer on the nanocomposites electric properties are shown. Important parameters from the atomic to the microlevel, such as interfacial chemistry, interfacial area, and degree of particle dispersion/aggregation, are discussed. This work is placed in perspective with important work by others, and suggested mechanisms for improved insulation using nanoparticles, such as increased charge trap density, adsorption of impurities/ions, and induced particle dipole moments are considered. The effects of the nanoparticles and of their interfacial structures on the mechanical properties and the implications of cavitation on the electric properties are also discussed. Although the main interest in improving the properties of insulating polymers has been on the use of nanoparticles, leading to nanodielectrics, it is pointed out here that larger microscopic hierarchical metal-oxide particles with high surface porosity also impart good insulation properties. The impact of the type of particle and its inherent properties (purity and conductivity) on the nanocomposite dielectric and insulating properties are also discussed based on data obtained by a newly developed technique to directly observe the charge distribution on a nanometer scale in the nanocomposite. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  8. Cooperative effect of radiation and vapor environments on the deterioration of insulator materials

    International Nuclear Information System (INIS)

    Kusama, Yasuo; Okada, Sohei; Yagi, Toshiaki; Ito, Masayuki; Yoshida, Kenzo; Tamura, Naoyuki

    1985-01-01

    Experimental results and speculations are described on the cooperative effect of radiation and vapor environments for the deterioration of insulator cable cladding materials such as polyethylene chlorosulphonate, ethylene propylene rubber, cross-linked polyethylene, chloroprene and silicone rubber, by the separate, simultaneous or subsequent exposure of the above-mentioned two kinds of exposure factors. These experiment was carried out by considering main environmental factors in the LOCA (loss of coolant accident) conditions. Radiation experiment was made by employing 60 Co source of 9.7 kGy/h at a room-temperature air condition. Vapor environment exposure was conducted by the conditions of 120 to 160 deg C steam-saturated air conditions and others. With the experimental results described on the characteristics of the five kinds of the above-mentioned insulator materials in radiation and saturated vapor conditions, the following conclusions were obtained. Acceleration of deterioration by the cooperative action of radiation and saturated vapor was found for the examined materials except the cross-linked polyethylene. In the subsequent exposure of radiation and saturated vapor, deterioration behavior was dependent on insulator materials and component ratios of the insulator materials. For the cross-linked polyethylene, annealing effect by heat was found, and the effect was less significent in the simultaneous exposure. Restoration phenomenon was found in the cross-linked polyethylene even in the saturated vapor exposure stage of the subsequent exposure conditions of radiation exposure followed by saturated vapor. (Takagi, S.)

  9. Evaluation of mechanical and thermal properties of insulation materials for HTS power devices at liquid nitrogen temperature

    Energy Technology Data Exchange (ETDEWEB)

    Shin, Hyung Seop; Diaz, Mark Angelo [Dept. of Mechanical Design Engineering, Andong National University, Andong (Korea, Republic of)

    2017-06-15

    In superconducting power devices including power cables in which high temperature superconducting (HTS) tapes are utilized, a reliable electrical insulation should be achieved for its maximum performance. For an efficient design of HTS superconducting devices, a comparative evaluation of the mechanical and thermal propperties for various insulation materials at cryogenic temperatures is required. Especially, in the process of the property evaluation of the sheet-shaped insulation materials, anisotropy according to the machining direction should be considered because the mechanical and thermal properties are significantly influenced by the sample orientation. In this study, the cryogenic thermal and mechanical properties of various insulation material sheets such as PPLP, Cryoflex, Teflon, and Kapton were determined considering sample orientation. All samples tested at cryogenic temperature showed significantly higher tensile strength as compared with that of room temperature. The ultimate tensile strength at both temperature conditions significantly depended upon the sample orientation. The thermal properties of the insulation materials exhibited a slight difference among samples depending on the orientation: for the PPLP and Cryoflex, the CD orientation showed larger thermal contraction up to 77 K as compared to the MD one. MD samples in PPLP and Cryoflex showed a lower CTE and thermal contraction which made it more promising as an insulation material due to its comparable CTE with HTS CC tapes.

  10. Gaseous products and smoke generation on combustion of the insulation materials of nuclear cables

    International Nuclear Information System (INIS)

    Noguchi, Isamu; Takami, Hiroshi; Ueyama, Michio; Fujimura, Shun-ichi.

    1976-01-01

    Serious requirements have been introduced to the cables used for nuclear power plants on their flame retardation in the IEEE Standard 383-1974. The movements that the users prescribe the quantity of corrosive gas generated from cables are also observed. This report describes on the measured results of the gaseous products generated by burning polyethylene, polyvinyl-chloride (PVC) and their flame-resistant products, and a part of the covering materials of the cables for nuclear power plants (flame-resistant, crosslinking polyethylene, flame-resistant, low hydrochloric acid PVC, flame-resistant jute) in the infra-red rapid heating combustion test facility designed by the Furukawa Electric Co. Ltd. In addition, the report introduces the test method for the smoke generation evaluation of polymers and a part of the measured results. The gaseous products of combustion were collected and determined quantitatively by gas chromatographic method. Since smoke generation is affected greatly by the kinds, shape, atmosphere, temperature, ignition procedure and others of burnt matters, the establishment of the evaluation test method is difficult, and a number of methods have been proposed. As the measured results showed, it is clear that smoke generation increases with the increase of flame resistant reagent addition. The smoke generation of PVC was of course great in quantity because it contains considerable amount of chlorine for its molecular structure. Flame-resistant polyethylene generates smoke much more than polyethylene without flame-resisting treatment because of its flame resistivity, but less than that of PVC. (Wakatsuki, Y.)

  11. Handleable shapes of thermal insulation material

    Energy Technology Data Exchange (ETDEWEB)

    Hughes, J. T.

    1989-01-17

    Handleable and machineable shapes of thermal insulation material are made by compacting finely divided thermal insulation material into the cells of a reinforcing honeycomb insulation material into the cells of a reinforcing honeycomb structure. The finely divided thermal insulation material may be, for example, silica aerogel, pyrogenic silica, carbon black, silica gel, volatilised silica, calcium silicate, vermiculate or perlite, or finely divided metal oxides such as alumina or titania. The finely divided thermal insulation material may include an infra-red opacifier and/or reinforcing fibres. The reinforcing honeycomb structure may be made from, for example, metals such as aluminium foil, inorganic materials such as ceramics, organic materials such as plastics materials, woven fabrics or paper. A rigidiser may be employed. The shapes of thermal insulation material are substantially rigid and may be machines, for example by mechanical or laser cutting devices, or may be formed, for example by rolling, into curved or other shaped materials. 12 figs.

  12. Radiation techology in cable making industry

    International Nuclear Information System (INIS)

    Kourim, P.; Vokal, A.

    1985-01-01

    Electron accelerators are used in radiation cross-linking of elastomer and thermoplastic layers of cable insulation and sheathing. Another application is cross-linking of insulation bands and moulded products to achieve thermal contractibility. Ionizing radiation is used for curing insulation lacquers on winding leads. In Czechoslovakia, problems of radiation curing of silicone rubber have been studied since 1973. Instrumentation has been installed including accelerators. The feasibility has also been studied of radiation cross-linking of insulation and semiconductor cable cores of hose-type trailing cables. Polyethylene mixes have been designed and prepared which are suitable for radiation cross-linking aimed at increasing thermal resistance above 100 degC. (M.D.)

  13. Physical degradation assessment of generator station cables

    International Nuclear Information System (INIS)

    Stonkus, D.J.

    1988-01-01

    Preliminary studies of fossil-fired and nuclear generator station cables indicate that the low voltage PVC insulated cables are in relatively good condition. The insulation is flexible and in the case of nuclear cables can withstand a design basis event after nearly 15 years of service. Cables insulated with styrene butadiene rubber have been found embrittled and cables insulated with SBR should be closely inspected in any plant assurance program. Thermal analysis using oxidative induction technique shows promise to indicate cable insulation degradation. Long term reliability assurance and plant life extension studies are being actively pursued at Ontario Hydro. A major study is currently underway to extend the life of the oldest operating fossil-fuel station, the 8-unit, 2400 MW Lakeview TGS in operation since the 1960s. Plant life assurance programs have been initiated at the 2000 MW Lambton TGS in operation since 1969, and for the oldest operating nuclear plant, Pickering NGS A in operation since the early 1970s. As cables are considered one of the critical components in a generator station due to the extreme difficulty and cost of cable replacement, test programs have been initiated to evaluate the physical degradation of the cables and relate the results to electrical diagnostic tests and to chemical changes. The decommissioning of two small nuclear stations, the 20 MW Nuclear Power Demonstration (NPD) and the 200 MW Douglas Point NGS, which were placed in service in 1962 and 1967 respectively, will provide an opportunity to perform destructive electrical and physical evaluation on field aged cables

  14. External heating of electrical cables and auto-ignition investigation.

    Science.gov (United States)

    Courty, L; Garo, J P

    2017-01-05

    Electric cables are now extensively used for both residential and industrial applications. During more than twenty years, multi-scale approaches have been developed to study fire behavior of such cables that represents a serious challenge. Cables are rather complicated materials because they consist of an insulated part and jacket of polymeric materials. These polymeric materials can have various chemical structures, thicknesses and additives and generally have a char-forming tendency when exposed to heat source. In this work, two test methods are used for the characterization of cable pyrolysis and flammability. The first one permits the investigation of cable pyrolysis. A description of the cable mass loss is obtained, coupling an Arrhenius expression with a 1D thermal model of cables heating. Numerical results are successfully compared with experimental data obtained for two types of cable commonly used in French nuclear power plants. The second one is devoted to ignition investigations (spontaneous or piloted) of these cables. All these basic observations, measurements and modelling efforts are of major interest for a more comprehensive fire resistance evaluation of electric cables. Copyright © 2016 Elsevier B.V. All rights reserved.

  15. Organic dielectrics in high voltage cables

    Energy Technology Data Exchange (ETDEWEB)

    Vermeer, J

    1962-03-01

    It appears that the limit has been reached in the applicability of oil-impregnated paper as the dielectric for ehv cables, as with rising voltages the prevention of conductor losses becomes increasingly difficult, while the dielectric losses of the insulation, increasing as the square of the voltage, contribute to a greater extent to the temperature rise of the conductor. The power transmitting capacity of ehv cables reaches a maximum at 500 to 600 kV for these reasons. Apart from artificial cooling, a substantial improvement can be obtained only with the use of insulating materials with much lower dielectric losses; these can moreover be applied with a smaller wall thickness, but this means higher field strengths. Synthetic polymer materials meet these requirements but can be used successfully only in the form of lapped film tapes impregnated with suitable liquids. The electrical properties of these heterogeneous dielectrics, in particular, their impulse breakdown strengths are studied in detail.

  16. Radiation effects on power cables for nuclear power plants

    International Nuclear Information System (INIS)

    Arora, R.; Munshi, P.; Badshah, M.G.Q.

    1988-01-01

    A large number of power and control cables, insulated with organic/polymeric materials, are installed quite near the reactor in nuclear power plants. The reliability of electrical equipment, receiving power through these cables, is critically important for the design and safety of the power stations. The radiation intensity inside the containment varies significantly from one location to another. The extent of material degradation is associated with the local radiation intensity. The cables used in the nuclear environment require several unique properties, the most obvious of these being radiation resistance, fire resistance, and the ability to withstand the loss-of-coolant accident in a nuclear power plant as specified in Institute of Electrical and Electronics Engineers (IEEE) Standard 383. In this study, four specific electrical power cable samples insulated with polyethylene, polyvinyl chloride, ethylene propylene rubber, and silicone rubber were chosen to investigate the effect of radiation in reactor environments on the electrical properties of the samples. Voltage breakdown tests and dielectric loss factor (tan δ) and conductor resistance measurements were carried out on each sample before and after irradiating them to near lifetime doses at ambient temperatures in atmospheric conditions

  17. Replacement of input/output cables of the digital control computers at Gentilly 2

    International Nuclear Information System (INIS)

    Melancon, P.; Lafreniere, P.

    1991-01-01

    During the 1990 annual outage at Gentilly 2 the Preventive Maintenance Program inspections on the digital control computers (DCCs) revealed an alarming degradation of cable insulation at several locations. It was found that approximately 20% of the cable connector assemblies inspected showed signs of degradation. These findings raised the concern of an increased risk of random short-circuit faults at the very heart of the station control system. Given the excellent reliability of the Gentilly 2 DCCs and their inherent design robustness, it was decided to proceed with the replacement of all of the complete cable connector assemblies within a reasonable time frame. It is planned to replace all assemblies of DCCX and DCCY during the 1991 annual outage. The degradation of the insulation was traced to a material incompatibility problem originating during cable manufacture. A migration of the plastifier contained in the PVC of the transparent sheaths, surrounding many of the cable conductors to terminal block connections, resulted in the chemical attack of the conductor insulation. This paper summarizes the problem identification and disposition process followed by Gentilly 2 Technical Unit personnel

  18. Dielectric and Insulating Technology 2004 : Review & Forecast

    Science.gov (United States)

    Okamoto, Tatsuki

    This article reports the state-of-art of DEIS activites. DEIS activiteis are basically based on the activites of 8-10 investigation committees’ under DEIS committee. Recent DEIS activites are categlized into three functions in this article and remarkable activity or trend of each category is mentioned. Those are activities on insulation diagnosis (AI application and asset management), activities on new insulation technology for power tansmission (high Tc super conducting cable insulation and all solid sinulated substation), and activities on new insulating materials (Nanocomposite).

  19. Life-assessment technique for nuclear power plant cables

    International Nuclear Information System (INIS)

    Bartonicek, B.; Hnat, V.; Placek, V.

    1998-01-01

    The condition of polymer-based cable material can be best characterized by measuring elongation at break of its insulating materials. However, it is not often possible to take sufficiently large samples for measurement with the tensile testing machine. The problem has been conveniently solved by utilizing differential scanning calorimetry technique. From the tested cable, several microsamples are taken and the oxidation induction time (OIT) is determined. For each cable which is subject to the assessment of the lifetime, the correlation of OIT with elongation at break and the correlation of elongation at break with the cable service time has to be performed. A reliable assessment of the cable lifetime depends on accuracy of these correlations. Consequently, synergistic effects well known at this time - dose rate effects and effects resulting from the different sequence of applying radiation and elevated temperature must be taken into account

  20. Negative differential mobility for negative carriers as revealed by space charge measurements on crosslinked polyethylene insulated model cables

    International Nuclear Information System (INIS)

    Teyssedre, G.; Laurent, C.; Vu, T. T. N.

    2015-01-01

    Among features observed in polyethylene materials under relatively high field, space charge packets, consisting in a pulse of net charge that remains in the form of a pulse as it crosses the insulation, are repeatedly observed but without complete theory explaining their formation and propagation. Positive charge packets are more often reported, and the models based on negative differential mobility(NDM) for the transport of holes could account for some charge packets phenomenology. Conversely, NDM for electrons transport has never been reported so far. The present contribution reports space charge measurements by pulsed electroacoustic method on miniature cables that are model of HVDC cables. The measurements were realized at room temperature or with a temperature gradient of 10 °C through the insulation under DC fields on the order 30–60 kV/mm. Space charge results reveal systematic occurrence of a negative front of charges generated at the inner electrode that moves toward the outer electrode at the beginning of the polarization step. It is observed that the transit time of the front of negative charge increases, and therefore the mobility decreases, with the applied voltage. Further, the estimated mobility, in the range 10 −14 –10 −13  m 2  V −1  s −1 for the present results, increases when the temperature increases for the same condition of applied voltage. The features substantiate the hypothesis of negative differential mobility used for modelling space charge packets

  1. Negative differential mobility for negative carriers as revealed by space charge measurements on crosslinked polyethylene insulated model cables

    Science.gov (United States)

    Teyssedre, G.; Vu, T. T. N.; Laurent, C.

    2015-12-01

    Among features observed in polyethylene materials under relatively high field, space charge packets, consisting in a pulse of net charge that remains in the form of a pulse as it crosses the insulation, are repeatedly observed but without complete theory explaining their formation and propagation. Positive charge packets are more often reported, and the models based on negative differential mobility(NDM) for the transport of holes could account for some charge packets phenomenology. Conversely, NDM for electrons transport has never been reported so far. The present contribution reports space charge measurements by pulsed electroacoustic method on miniature cables that are model of HVDC cables. The measurements were realized at room temperature or with a temperature gradient of 10 °C through the insulation under DC fields on the order 30-60 kV/mm. Space charge results reveal systematic occurrence of a negative front of charges generated at the inner electrode that moves toward the outer electrode at the beginning of the polarization step. It is observed that the transit time of the front of negative charge increases, and therefore the mobility decreases, with the applied voltage. Further, the estimated mobility, in the range 10-14-10-13 m2 V-1 s-1 for the present results, increases when the temperature increases for the same condition of applied voltage. The features substantiate the hypothesis of negative differential mobility used for modelling space charge packets.

  2. External heating of electrical cables and auto-ignition investigation

    Energy Technology Data Exchange (ETDEWEB)

    Courty, L., E-mail: leo.courty@univ-orleans.fr [Univ. Orleans, PRISME EA 4229, 63 Avenue de Lattre de Tassigny, 18020 Bourges (France); Garo, J.P. [Institut P’, UPR 3346 CNRS, ENSMA, Univ. Poitiers, 1 Av. Clément Ader, Téléport 2, BP 40109, 86961 Futuroscope Chasseneuil (France)

    2017-01-05

    Highlights: • Electrical cables pyrolysis and flammability have been studied. • Two different experimental setups were used to study cables mass loss and flammability. • A 1-D thermal model for cables mass loss and temperature is proposed. • Spontaneous and piloted ignitions have been investigated. - Abstract: Electric cables are now extensively used for both residential and industrial applications. During more than twenty years, multi-scale approaches have been developed to study fire behavior of such cables that represents a serious challenge. Cables are rather complicated materials because they consist of an insulated part and jacket of polymeric materials. These polymeric materials can have various chemical structures, thicknesses and additives and generally have a char-forming tendency when exposed to heat source. In this work, two test methods are used for the characterization of cable pyrolysis and flammability. The first one permits the investigation of cable pyrolysis. A description of the cable mass loss is obtained, coupling an Arrhenius expression with a 1D thermal model of cables heating. Numerical results are successfully compared with experimental data obtained for two types of cable commonly used in French nuclear power plants. The second one is devoted to ignition investigations (spontaneous or piloted) of these cables. All these basic observations, measurements and modelling efforts are of major interest for a more comprehensive fire resistance evaluation of electric cables.

  3. External heating of electrical cables and auto-ignition investigation

    International Nuclear Information System (INIS)

    Courty, L.; Garo, J.P.

    2017-01-01

    Highlights: • Electrical cables pyrolysis and flammability have been studied. • Two different experimental setups were used to study cables mass loss and flammability. • A 1-D thermal model for cables mass loss and temperature is proposed. • Spontaneous and piloted ignitions have been investigated. - Abstract: Electric cables are now extensively used for both residential and industrial applications. During more than twenty years, multi-scale approaches have been developed to study fire behavior of such cables that represents a serious challenge. Cables are rather complicated materials because they consist of an insulated part and jacket of polymeric materials. These polymeric materials can have various chemical structures, thicknesses and additives and generally have a char-forming tendency when exposed to heat source. In this work, two test methods are used for the characterization of cable pyrolysis and flammability. The first one permits the investigation of cable pyrolysis. A description of the cable mass loss is obtained, coupling an Arrhenius expression with a 1D thermal model of cables heating. Numerical results are successfully compared with experimental data obtained for two types of cable commonly used in French nuclear power plants. The second one is devoted to ignition investigations (spontaneous or piloted) of these cables. All these basic observations, measurements and modelling efforts are of major interest for a more comprehensive fire resistance evaluation of electric cables.

  4. Benchmark Analysis for Condition Monitoring Test Techniques of Aged Low Voltage Cables in Nuclear Power Plants. Final Results of a Coordinated Research Project

    International Nuclear Information System (INIS)

    2017-10-01

    This publication provides information and guidelines on how to monitor the performance of insulation and jacket materials of existing cables and establish a programme of cable degradation monitoring and ageing management for operating reactors and the next generation of nuclear facilities. This research was done through a coordinated research project (CRP) with participants from 17 Member States. This group of experts compiled the current knowledge in a report together with areas of future research and development to cover aging mechanisms and means to identify and manage the consequences of aging. They established a benchmarking programme using cable samples aged under thermal and/or radiation conditions, and tested before and after ageing by various methods and organizations. In particular, 12 types of cable insulation or jacket material were tested, each using 14 different condition monitoring techniques. Condition monitoring techniques yield usable and traceable results. Techniques such as elongation at break, indenter modulus, oxidation induction time and oxidation induction temperature were found to work reasonably well for degradation trending of all materials. However, other condition monitoring techniques, such as insulation resistance, were only partially successful on some cables and other methods like ultrasonic or Tan δ were either unsuccessful or failed to provide reliable information to qualify the method for degradation trending or ageing assessment of cables. The electrical in situ tests did not show great promise for cable degradation trending or ageing assessment, although these methods are known to be very effective for finding and locating faults in cable insulation material. In particular, electrical methods such as insulation resistance and reflectometry techniques are known to be rather effective for locating insulation damage, hot spots or other faults in essentially all cable types. The advantage of electrical methods is that they can be

  5. High temperature superconductor cable concepts for fusion magnets

    CERN Document Server

    AUTHOR|(CDS)2078397

    2013-01-01

    Three concepts of high temperature superconductor cables carrying kA currents (RACC, CORC and TSTC) are investigated, optimized and evaluated in the scope of their applicability as conductor in fusion magnets. The magnetic field and temperature dependence of the cables is measured; the thermal expansion and conductivity of structure, insulation and filling materials are investigated. High temperature superconductor winding packs for fusion magnets are calculated and compared with corresponding low temperature superconductor cases.

  6. Dielectric and Insulating Technology 2005 : Reviews & Forecasts

    Science.gov (United States)

    Okamoto, Tatsuki

    This article reports the state-of-art of TC-DEI ( Technical Committee of Dielectrics and Electrical Insulation of IEEJ) activites. The activiteis are basically based on the activites of 8-10 investigation committees under TC-DEI. Recent activites were categorized into three functions in this article and remarkable activity or trend for each category is mentioned as was done in the article of 2003. Thoese are activities on asset management (AI application and insulation diagnosis), activities on new insulating and functional materials (Nano composite) and activities on new insulation technology for power tansmission (high Tc superconducting cable insulation).

  7. Dielectric and Insulating Technology 2006 : Review & Forecast

    Science.gov (United States)

    Okamoto, Tatsuki

    This article reports the state-of-art of TC-DEI ( Technical Committee of Dielectrics and Electrical Insulation of IEEJ) activites. The activiteis are basically based on the activites of 8-10 investigation committees under TC-DEI. Recent activites were categorized into three functions in this article and remarkable activity or trend for each category is mentioned as was seen in the articles of 2005. Those are activities on asset management (AI application and insulation diagnosis), activities on new insulating and functional materials (Nano composite) and activities on new insulation technology for power tansmission (high Tc superconducting cable insulation).

  8. Degradation diagnosing method for low voltage electric wire and cable in nuclear facility

    International Nuclear Information System (INIS)

    Kamimura, Seiji; Seki, Ikuo; Yagyu, Hideki; Onishi, Takao; Kusama, Yasuo.

    1991-01-01

    A considerable skill is required for a visual inspection method which has been used most widely for determining the degradation of low voltage electric wires and cables used mostly in facilities such as nuclear power plants. It is extremely difficult to determine the degradation accurately and appropriately even for skilled inspectors because of individual difference. Then, a small amount of organic insulation materials is taken as a sample from insulators or sheath materials actually disposed. The pyrolytic temperature of the sample is measured by thermal gravimetric analysis to determine the extent of the degradation of the electric wire and cable based on the relationship between the degradation and the elongation. Since there is a close relationship between the temperature at which the measured weight of the sample is reduced by 5% and the degradation behavior of the mechanical property, analysis can be conducted effectively by an extremely small amount of the sample. Since the insulation degradation of relatively low voltage electric wires and cables can be determined in a non-destructive manner at high accuracy, the lifetime can be forecasted. (N.H.)

  9. Insulating and sheathing materials of electric and optical cables: common test methods part 4-1: methods specific to polyethylene and polypropylene compounds – resistance to environmental stress cracking – measurement of the melt flow index – carbon black and/or mineral filler content measurement in polyethylene by direct combustion – measurement of carbon black content by thermogravimetric analysis (TGA) – assessment of carbon black dispersion in polyethylene using a microscope

    CERN Document Server

    International Electrotechnical Commission. Geneva

    2004-01-01

    Specifies the test methods to be used for testing polymeric insulating and sheathing materials of electric cables for power distribution and telecommunications including cables used on ships. Gives the methods for measurements of the resistance to environmental stress cracking, for wrapping test after thermal ageing in air, for measurement of melt flow index and for measurement of carbon black and/or mineral filler content, which apply to PE and PP coumpounds, including cellular compounds and foam skin for insulation.

  10. Literature review of environmental qualification of safety-related electric cables: Summary of past work. Volume 1

    Energy Technology Data Exchange (ETDEWEB)

    Subudhi, M. [Brookhaven National Lab., Upton, NY (United States)

    1996-04-01

    This report summarizes the findings from a review of published documents dealing with research on the environmental qualification of safety-related electric cables used in nuclear power plants. Simulations of accelerated aging and accident conditions are important considerations in qualifying the cables. Significant research in these two areas has been performed in the US and abroad. The results from studies in France, Germany, and Japan are described in this report. In recent years, the development of methods to monitor the condition of cables has received special attention. Tests involving chemical and physical examination of cable`s insulation and jacket materials, and electrical measurements of the insulation properties of cables are discussed. Although there have been significant advances in many areas, there is no single method which can provide the necessary information about the condition of a cable currently in service. However, it is possible that further research may identify a combination of several methods that can adequately characterize the cable`s condition.

  11. Plastic Materials for Insulating Applications.

    Science.gov (United States)

    Wang, S. F.; Grossman, S. J.

    1987-01-01

    Discusses the production and use of polymer materials as thermal insulators. Lists several materials that provide varying degrees of insulation. Describes the production of polymer foam and focuses on the major applications of polystyrene foam, polyurethane foam, and polyisocyanurate foam. (TW)

  12. Frequency Domain Reflectometry NDE for Aging Cables in Nuclear Power Plants

    Energy Technology Data Exchange (ETDEWEB)

    Glass, Samuel W.; Jones, Anthony M.; Fifield, Leonard S.; Hartman, Trenton S.

    2017-02-16

    Cable insulation polymers are among the more susceptible materials to age-related degradation within a nuclear power plant. This is recognized by both regulators and utilities, so all plants have developed cable aging management programs to detect damage before critical component failure in compliance with regulatory guidelines. Although a wide range of tools are available to evaluate cables and cable systems, cable aging management programs vary in how condition monitoring and nondestructive examinations are conducted as utilities search for the most reliable and cost-effective ways to assess cable system condition. Frequency domain reflectometry (FDR) is emerging as one valuable tool to locate and assess damaged portions of a cable system with minimal cost and only requires access in most cases to one of the cable terminal ends. Since laboratory studies to evaluate the use of FDR for inspection of aged cables can be expensive and data interpretation may be confounded by multiple factors which influence results, a model-based approach is desired to parametrically investigate the effect of insulation material damage in a controlled manner. This work describes development of a physics-based FDR model which uses finite element simulations of cable segments in conjunction with cascaded circuit element simulations to efficiently study a cable system. One or more segments of the cable system model have altered physical or electrical properties which represent the degree of damage and the location of the damage in the system. This circuit model is then subjected to a simulated FDR examination. The modeling approach is verified using several experimental cases and by comparing it to a commercial simulator suitable for simulation of some cable configurations. The model is used to examine a broad range of parameters including defect length, defect profile, degree of degradation, number and location of defects, FDR bandwidth, and addition of impedance-matched extensions to

  13. Superconducting ac cable

    Science.gov (United States)

    Schmidt, F.

    1980-11-01

    The components of a superconducting 110 kV ac cable for power ratings or = 2000 MVA were developed. The cable design is of the semiflexible type, with a rigid cryogenic envelope containing a flexible hollow coaxial cable core. The cable core consists of spirally wound Nb-A1 composite wires electrically insulated by high pressure polyethylene tape wrappings. A 35 m long single phase test cable with full load terminals rated at 110 kV and 10 kA was constructed and successfully tested. The results obtained prove the technical feasibility and capability of this cable design.

  14. Superconducting ac cable

    International Nuclear Information System (INIS)

    Schmidt, F.

    1980-01-01

    The components of a superconducting 110 kV ac cable for power ratings >= 2000 MVA have been developed. The cable design especially considered was of the semiflexible type, with a rigid cryogenic envelope and flexible hollow coaxial cable cores pulled into the former. The cable core consists of spirally wound Nb-Al composite wires and a HDPE-tape wrapped electrical insulation. A 35 m long single phase test cable with full load terminations for 110 kV and 10 kA was constructed and successfully tested. The results obtained prove the technical feasibility and capability of our cable design. (orig.) [de

  15. Recent Progress in Electrical Insulation Techniques for HTS Power Apparatus

    Science.gov (United States)

    Hayakawa, Naoki; Kojima, Hiroki; Hanai, Masahiro; Okubo, Hitoshi

    This paper describes the electrical insulation techniques at cryogenic temperatures, i.e. Cryodielectrics, for HTS power apparatus, e.g. HTS power transmission cables, transformers, fault current limiters and SMES. Breakdown and partial discharge characteristics are discussed for different electrical insulation configurations of LN2, sub-cooled LN2, solid, vacuum and their composite insulation systems. Dynamic and static insulation performances with and without taking account of quench in HTS materials are also introduced.

  16. Development of a superconducting cable for transmission of high electric power

    International Nuclear Information System (INIS)

    Moisson, F.; Leroux, J.M.

    1971-01-01

    The opportunities opened by the use of cryoresistive and superconducting materials in underground transmission systems have led to a cryocable program. A first set of problems associated with the development of cryogenic cables deals with the cable system, i.e., design, safety, terminal equipment including leads, cryogenic equipment, refrigerators, and problems related to overload capability and reliability. A second set concerns the cable itself, i.e., scientific and technological problems associated with the conductor, the electrical insulation, and the thermal exchange between conductor and helium. Useful experience is gained on the design problems and on the technological problems involved in the construction of a cryoconducting cable. A 20-M aluminum cable cooled down to 25 0 K with pressurized helium flow was built and tested with 3500-A dc under 20 Kv; results are presented. On this model the following types of problems were solved. First, mechanical problems concerning cooling of the cable, thermal contraction of the pipes, electrical insulation and conductors, construction of an invariable cable constituted by elementary helically wound conductors were solved. Second, thermal problems of reduction of heat leaks, conception of thermal insulation, and segmentation of vacuum jackets were solved. Third, electrical problems of design of 300 0 to 25 0 K leads were solved; this problem of losses at both ends is, in proportion, more important for the short model than for long cable. Finally, refrigeration problems of helium and nitrogen flows, thermal shields and design of refrigerators (optimal capacity and spacing) were solved

  17. Semiannual report for the period April 1 to September 30, 1978 of work on: (1) superconducting power transmission system development; (2) cable insulation development. Power Transmission Project technical note No. 83

    Energy Technology Data Exchange (ETDEWEB)

    1978-11-07

    Progress in the development, fabrication and testing of superconductors for HVAC power transmission systems is reported. Information is included on the materials evaluation of superconducting alloys, production of tapes from these alloys, principally Nb/sub 3/Sn cable insulation requirements and development, and the cryogenic equipment used in this research program. (LCL)

  18. Negative differential mobility for negative carriers as revealed by space charge measurements on crosslinked polyethylene insulated model cables

    Energy Technology Data Exchange (ETDEWEB)

    Teyssedre, G., E-mail: gilbert.teyssedre@laplace.univ-tlse.fr; Laurent, C. [Université de Toulouse, UPS, INPT, LAPLACE (Laboratoire Plasma et Conversion d' Energie), 118 route de Narbonne, F-31062 Toulouse cedex 9 (France); CNRS, LAPLACE, F-31062 Toulouse (France); Vu, T. T. N. [Université de Toulouse, UPS, INPT, LAPLACE (Laboratoire Plasma et Conversion d' Energie), 118 route de Narbonne, F-31062 Toulouse cedex 9 (France); Electric Power University, 235 Hoang Quoc Viet, 10000 Hanoi (Viet Nam)

    2015-12-21

    Among features observed in polyethylene materials under relatively high field, space charge packets, consisting in a pulse of net charge that remains in the form of a pulse as it crosses the insulation, are repeatedly observed but without complete theory explaining their formation and propagation. Positive charge packets are more often reported, and the models based on negative differential mobility(NDM) for the transport of holes could account for some charge packets phenomenology. Conversely, NDM for electrons transport has never been reported so far. The present contribution reports space charge measurements by pulsed electroacoustic method on miniature cables that are model of HVDC cables. The measurements were realized at room temperature or with a temperature gradient of 10 °C through the insulation under DC fields on the order 30–60 kV/mm. Space charge results reveal systematic occurrence of a negative front of charges generated at the inner electrode that moves toward the outer electrode at the beginning of the polarization step. It is observed that the transit time of the front of negative charge increases, and therefore the mobility decreases, with the applied voltage. Further, the estimated mobility, in the range 10{sup −14}–10{sup −13} m{sup 2} V{sup −1} s{sup −1} for the present results, increases when the temperature increases for the same condition of applied voltage. The features substantiate the hypothesis of negative differential mobility used for modelling space charge packets.

  19. The Danish Superconducting Cable Project

    DEFF Research Database (Denmark)

    Tønnesen, Ole

    1997-01-01

    The design and construction of a superconducting cable is described. The cable has a room temperature dielectric design with the cryostat placed inside the electrical insulation.BSCCO 2223 superconducting tapes wound in helix form around a former are used as the cable conductor. Results from...

  20. Modelling of long High Voltage AC Cables in the Transmission System

    DEFF Research Database (Denmark)

    Gudmundsdottir, Unnur Stella

    : conductor-insulation (with or without SC layers)-conductor-insulation(-conductor-insulation), whereas a transmission line single core XLPE cable will normally have the configuration: conductor-SC layerinsulation-SC layer-conductor-SC layer-conductor-insulation. Furthermore the existing cable models use......, EMTDC/PSCAD is provided. A typical HV AC underground power cable is formed by 4 main layers, namely; Conductor-Insulation-Screen-Insulation. In addition to these main layers, the cable also has semiconductive screens, swelling tapes and metal foil. For high frequency modelling in EMT-based software......-SC layer-solid hollow conductor) is implemented in the model. These improvements result in a more correct series impedance and hence a more correct damping of the simulations. Even though the series impedance is more correct, it does still not include the proximity effect and high frequency oscillations...

  1. Characteristics of SUS-MI cables and it's application to wiring in nuclear power facilities

    International Nuclear Information System (INIS)

    Okuno, Michio; Sato, Toshio; Handa, Katsue; Ohya, Shingo; Ioroi, Masaya

    1984-01-01

    SUS-MI cables are the inorganic insulation cables using austenitic stainless steel SUS 321 as the sheath, oxygen-free copper as the conductor and high purity magnesium oxide as the insulatingmaterial. Because of the excellent characteristics of the composing materials, the properties withstanding radiation, fire and heat, and sodium of the cables are superior. In the nuclear power facilities being developed such as fast breeder reactors and nuclear fusion reactors, there is the environment the cables with organic materials as the components cannot meet. As the cables to be applied to such places, the SUS-MI cables are most suitable. In this report, the electric properties and the mechanical strength of the cables and the examples of practical use are described. The highest temperature of using the SUS-MI cables is 800 deg C. The form and the composing materials of the SUS-MI cables, the characteristics and the cable laying are reported. Ceramic connectors and heat-resistant wall penetration parts were developed. The characteristics of the cables for the preheaters of fast breeder reactors are compared. (Kako, I.)

  2. Frequency domain reflectometry modeling for nondestructive evaluation of nuclear power plant cables

    Science.gov (United States)

    Glass, S. W.; Fifield, L. S.; Jones, A. M.; Hartman, T. S.

    2018-04-01

    Cable insulation polymers are among the more susceptible materials to age-related degradation within a nuclear power plant. This is recognized by both regulators and utilities, so all plants have developed cable aging management programs to detect damage before critical component failure in compliance with regulatory guidelines. Although a wide range of tools are available to evaluate cables and cable systems, cable aging management programs vary in how condition monitoring and nondestructive examinations are conducted as utilities search for the most reliable and cost-effective ways to assess cable system condition. Frequency domain reflectometry (FDR) is emerging as one valuable tool to locate and assess damaged portions of a cable system with minimal cost and only requires access in most cases to one of the cable terminal ends. Since laboratory studies to evaluate the use of FDR for inspection of aged cables can be expensive and data interpretation may be confounded by multiple factors which influence results, a model-based approach is desired to parametrically investigate the effect of insulation material damage in a controlled manner. This work describes development of a physics-based FDR model which uses finite element simulations of cable segments in conjunction with cascaded circuit element simulations to efficiently study a cable system. One or more segments of the cable system model have altered physical or electrical properties which represent the degree of damage and the location of the damage in the system. This circuit model is then subjected to a simulated FDR examination. The modeling approach is verified using several experimental cases and by comparing it to a commercial simulator suitable for simulation of some cable configurations. The model is used to examine a broad range of parameters including defect length, defect profile, degree of degradation, number and location of defects, FDR bandwidth, and addition of impedance-matched extensions to

  3. Neutron detector with gamma compensated cable

    International Nuclear Information System (INIS)

    Warren, H.D.

    1975-01-01

    An illustrative embodiment of the invention describes a technique for essentially eliminating the radiation induced background currents that are generated in the cable that connects an ''in-core'' neutron detector to an electrical terminal that is outside of the reactor's radiation field. This undesirable radiation-induced cable current is suppressed through an appropriate selection of conductor and cable sheath materials and sizes that generally satisfy the equation: Z/sub l/sup n/d/sub l/ = Z/sub s/sup m/d/sub s/ where Z is the atomic number of the material; d is a characteristic of the size of the cable component; m and/n have values between 1 and 5 to express the electron emissivity of the cable component from photoelectric and Compton effects; l represents the conductor; and s represents the sheath. Thus, the radiation-generated electrons emitted from the conductor and the oppositely-directed electrons emitted from the inner surface of the cable sheath are mutually cancelled if this equation is satisfied. A typical cable that does meet this criterion at low temperatures has a centrally disposed Zircaloy-2 inner conductor of 0.011 inch diameter, an annular insulation of magnesium oxide powder compacted to 100 percent density, and an Inconel sheath with an outside diameter of 0.062 inch and 0.011 inch wall thickness. (auth)

  4. Literature review of environmental qualification of safety-related electric cables: Summary of past work. Volume 1

    International Nuclear Information System (INIS)

    Subudhi, M.

    1996-04-01

    This report summarizes the findings from a review of published documents dealing with research on the environmental qualification of safety-related electric cables used in nuclear power plants. Simulations of accelerated aging and accident conditions are important considerations in qualifying the cables. Significant research in these two areas has been performed in the US and abroad. The results from studies in France, Germany, and Japan are described in this report. In recent years, the development of methods to monitor the condition of cables has received special attention. Tests involving chemical and physical examination of cable's insulation and jacket materials, and electrical measurements of the insulation properties of cables are discussed. Although there have been significant advances in many areas, there is no single method which can provide the necessary information about the condition of a cable currently in service. However, it is possible that further research may identify a combination of several methods that can adequately characterize the cable's condition

  5. A study on the condition monitoring for safety-related electric cables

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Chul Hwan; Ahn, S. P.; Yeo, S. M.; Kang, Y. S.; Ahn, S. M.; Kim, I. S.; Kim, D. S.; Kang, J. S. [Sungkyunkwan Univ., Suwon (Korea, Republic of)

    2002-03-15

    In this report, we have studied compositions and characteristics of various types of insulation material for cables in Nuclear Power Plant. We arrange relationship with condition monitoring methods. Also, we propose new condition monitoring method using third harmonic frequency. We test the proposed method with CV cables. We also describe about feature of condition monitoring such as application, theory, characteristic, thereby other engineer can confirm to advantage and disadvantage for each method, and possibly choice adequate condition monitoring method for various types of cables.

  6. Development of environmental-friendly wire and cable

    International Nuclear Information System (INIS)

    Ueno, Keiji

    1996-01-01

    The electron beam technology has been used in many industrial fields as a method of conventional polymer modification or optimum processability. The main industrial fields of radiation crosslinking are wire and cable, heat shrinkable tubings, plastic foams, precuring of tires, floppy disk curing, foods packaging films, and so on. The radiation crosslinking of wire and cable was started in 1961 in Japan and 15 wire and cable companies are now using electron beam accelerators for production or R and D. The dominant characteristics of crosslinking of insulation materials are application at high temperature, good oil and chemical resistibility and high mechanical properties. These radiation crosslinking wire and cable are applied widely in electronics equipments and automobiles. Recently, electronics manufacturers have indicated deep concern over the effects on the environment. Wire and cable also are required to be applicable for environmental preservation. (J.P.N.)

  7. The moisture proof connection of signal cables on test rig instrumentation

    Energy Technology Data Exchange (ETDEWEB)

    Joung, Chang Young; Ahn, Sung Ho; Hong, Jin Tae; Jeong, Hwang Young [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2012-10-15

    The rod inner pressure, centerline temperature, coolant temperature, and neutron flux resulting from the irradiation properties of nuclear fuel are an important factor for evaluating nuclear fuel properties in pile. In addition instrumentation and measurement techniques for nuclear fuel are necessary to measure the exact data. Special sensors such as a TC (thermocouple), LVDT (linear variable differential transformer) and SPND (self-powered neutron detector) are instrumented in and out of the fuel rod to measure the various irradiation characteristics of the nuclear fuel. These sensors are made up of the sensor itself and a signal cable. In the instrumentation, an MI (Mineral Insulated) cable used as the signal cable has such properties as high electrical insulation, heat resistance, and mechanical strength. However, it is difficult to handle and treat with care owing to the extremely hard composition, which is made up of weak signal wires and alumina powder in a stainless tube. The sealing of the end tip of the MI cable and extension cable is very important in terms of the insulation resistance to seal the insulator inside the MI cable tube from moisture. To maintain the insulation of sensors and signal cables, the insulation resistance must be checked in accordance with each process throughout the instrumentation and fabrication period. To safely mount the signal cables drawn from a fuel test rig on the terminal block of a junction panel, the MI and extension cables should be easy to connect. Therefore, it is necessary to develop instrumentation technologies of a moisture proof connection process for a fuel test rig. This paper will provide an overview of the work done with moisture proof connection procedures to connect the MI and extension cables to extend the MI cables jointed with the sensor.

  8. Analytical studies on hotspot temperature of cable-in-conduit conductors

    International Nuclear Information System (INIS)

    Yoshida, Kiyoshi; Takigami, Hiroyoshi; Kubo, Hiroatsu

    2001-01-01

    This paper describes an analytical study to review the hotspot temperature design criteria of the cable-in-conduit conductors for the ITER magnet system. The ITER magnet system uses three kinds of cable-in-conduit conductors for the Toroidal Field (TF) coils, the Central Solenoid (CS) and the Poloidal Field (PF) coils. The amount of copper in the superconducting cable has been defined by using the classical hotspot temperature design criteria that is based on the adiabatic condition. In the current design, ITER superconducting cables include a large amount of pure copper strands to satisfy the classical criteria. However, temperature and stress in the conduit and insulations after quench can be simulated with the quench simulation program and stress analysis program using the latest analysis tools. This analysis shows that the strand temperature is dominated by the conduction along strands and the heat capacity of other conductor materials and coolant. The hotspot temperature depends strongly on the delay time for quench detection. This analysis provides an estimation of delay times for quench detection. The thermal and stress analysis can provide the maximum allowable temperature after quench by determination of a failure or a functional disorder condition of the jacket material and turn insulation. In conclusion, it is found that the current density of the cable space can be increased, by reducing the extra copper strand, thereby, allowing a reduction of the coil radial build. (author)

  9. Insulating materials from renewable raw materials. 4. ed.; Daemmstoffe aus nachwachsenden Rohstoffen

    Energy Technology Data Exchange (ETDEWEB)

    Brandhorst, Joerg; Spritzendorfer, Josef; Gildhorn, Kai; Hemp, Markus

    2012-03-27

    The thermal insulation has become a central issue in the construction and renovation of buildings. The question of healthy building materials and appropriate construction follows the desire of a comfartable and allergy-free living. Due to these developments, insulation materials from renewable resources increasingly has raised the consciousness. The brochure under consideration describes the dynamic market of insulation materials consisting of renewable raw materials. Wood fibers, wood wool, sheep wool, flax, hemp, reeds, meadow grass, cork, cellulose, seaweed and bulrushes are considered as renewable raw materials for insulating materials.

  10. Conventional cable testing methods: strengths, weaknesses and possibilities

    International Nuclear Information System (INIS)

    Reynolds, P.H.

    1988-01-01

    The paper reviews the major conventional methods that can be used to test power plant cables. It assesses their usefulness in diagnosing the condition of the insulation of the cable and then proposes some possible directions for innovation. The methods examined are dc insulation resistance measurement, ac signal injection for continuous monitoring and fault location, and the ac measurement of capacitance and loss angle. Specific subjects considered are the effects of temperature, cable construction and installation, and the validity of insulation resistance or loss angle measurement. The innovative proposals refer to the use of automation in the measurement and of computer-based Expert Systems for the evaluation of the results

  11. Synthesis and characterization of innovative insulation materials

    Directory of Open Access Journals (Sweden)

    Skaropoulou Aggeliki

    2018-01-01

    Full Text Available Insulation elements are distinguished in inorganic fibrous and organic foamed materials. Foamed insulation materials are of great acceptance and use, but their major disadvantage is their flammability. In case of fire, they tend to transmit the flame producing toxic gases. In this paper, the synthesis and characterization of innovative inorganic insulation materials with properties competitive to commercial is presented. Their synthesis involves the mixing of inorganic raw material and water with reinforcing agent or/and foaming agent leading to the formation of a gel. Depending on raw materials nature, the insulation material is produced by freeze drying or ambient drying techniques of the gel. The raw material used are chemically benign and abundantly available materials, or industrial by-products and the final products are non-toxic and, in some cases, non-flammable. Their density and thermal conductivity was measured and found 0.02-0.06 g/cm3 and 0.03-0.04 W/mK, respectively.

  12. Methodology for Evaluating Raw Material Changes to RSRM Elastomeric Insulation Materials

    Science.gov (United States)

    Mildenhall, Scott D.; McCool, Alex (Technical Monitor)

    2001-01-01

    The Reusable Solid Rocket Motor (RSRM) uses asbestos and silicon dioxide filled acrylonitrile butadiene rubber (AS-NBR) as the primary internal insulation to protect the case from heat. During the course of the RSRM Program, several changes have been made to the raw materials and processing of the AS-NBR elastomeric insulation material. These changes have been primarily caused by raw materials becoming obsolete. In addition, some process changes have been implemented that were deemed necessary to improve the quality and consistency of the AS-NBR insulation material. Each change has been evaluated using unique test efforts customized to determine the potential impacts of the specific raw material or process change. Following the evaluations, the various raw material and process changes were successfully implemented with no detectable effect on the performance of the AS-NBR insulation. This paper will discuss some of the raw material and process changes evaluated, the methodology used in designing the unique test plans, and the general evaluation results. A summary of the change history of RSRM AS-NBR internal insulation is also presented.

  13. Development of cables for nuclear fuel processing facilities

    International Nuclear Information System (INIS)

    Kamimura, Seiji; Seki, Ikuo; Yamamoto, Yasuaki; Matsuyama, Shigeki; Endo, Shigeru; Yagi, Toshiaki; Kawakami, Waichiro.

    1988-01-01

    Accompanying the development of nuclear power stations, the expansion and repletion of the facilities for nuclear fuel cycle such as fuel reprocessing facilities and waste treatment facilities are requested. In these facilities, there is the environment which is exposed to very high level radiation, and in this case, the cables withstanding 10 MGy radiation dose are required. As the cables meeting such requirement, the new cables having excellent flexibility and radiation resistance were developed. In this paper, the points of material development and the characteristics of cables are reported. Considering the radiation resistance and others, ethylene propylene rubber was selected as the base polymer of the insulator, and polyethylene chlorosulfonate was selected as the sheath material. In order to give excellent radiation resistance, as the anti-rad, energy transfer type aromatic oil that absorbs and dissipates radiation energy and radical trap type anti-oxidant of amine group that catches and stabilizes the radicals generated in the polymer were added. The bromine group burning retarding agent having excellent radiation resistance was applied. In this way, the cables withstanding high radiation dose up to 10 MGy were able to be developed. (K.I.)

  14. Complete Fiber/Copper Cable Solution for Long-Term Temperature and Pressure Measurement in Supercritical Reservoirs and EGS Wells

    Energy Technology Data Exchange (ETDEWEB)

    Pastouret, Alan [Draka Cableteq USA, Inc., North Dighton, MA (United States); Gooijer, Frans [Draka Cableteq USA, Inc., North Dighton, MA (United States); Overton, Bob [Draka Cableteq USA, Inc., North Dighton, MA (United States); Jonker, Jan [Draka Cableteq USA, Inc., North Dighton, MA (United States); Curley, Jim [Draka Cableteq USA, Inc., North Dighton, MA (United States); Constantine, Walter [Draka Cableteq USA, Inc., North Dighton, MA (United States); Waterman, Kendall Miller [Draka Cableteq USA, Inc., North Dighton, MA (United States)

    2015-11-13

    -temperature insulated wire conductors Prysmian Group has developed a geothermal fiber optic cable (GFOC) solution which incorporates novel glass chemistry for optical fibers to operate at the required bandwidths in high temperature/high pressure hydrogen rich environments with fiber protection, high temperature insulated conductors and protective cladding for cable components. The cable solution has been tested in a geothermal installation for 10 months. The electrical insulation and optical fibers have been validated through laboratory testing to ensure successful operation for greater than 5 years at 300°C, with the possibility of higher temperatures depending on the particular well environment. With the 300°C optical fiber and electrical insulation developments completed and validated in laboratory tests the greatest challenge to a complete 300°C cable solution was protecting the optical fibers in the cable. Optical fibers are typically incased in a protective tube where the tube is filled with a gel. The gel serves as mechanical protection, prevent moisture ingress, and can include hydrogen scavenging materials. A suitable gel for use at 300°C could not be identified and an industrialized alternative was not fully attained. Despite the problems encountered and the lower long-term operating temperature of the cable solution, the project showed success in developing a complete cable solution for a large portion of the geothermal wells in operation today. Further work to obtain the higher long-term temperature goal of the project can be achieved based on the knowledge gained in the current project. This project is significant for many reasons including the new materials science, manufacturing technology, energy independence, and jobs created and will create.

  15. Effects of radiation on insulation materials

    International Nuclear Information System (INIS)

    Poehlchen, R.

    1992-01-01

    This presentation will concentrate on the insulation materials which are suitable for the insulation of superconducting magnets for fusion. For the next generation of fusion machines with magnetic confinement as NET and ITER general agreement exists that the insulation will consist of fibre reinforced organic matrix material, a composite. Much effort has been put into the investigation of the radiation resistance of such materials during the last 20-30 years, see in particular the numerous reports of accelerator laboratories on this subject. But very few of the published data are relevant for the superconducting magnets of fusion machines. Either the irradiation and testing was carried out at RT or LN 2 temperature and/or the irradiation spectrum was not representative for a fusion machine and/or the materials investigated are not applicable for the insulation of S.C. fusion magnets. Therefore test programs have been launched recently, one by the NET team. The intention of the first chapter is to give guidance on the choice of materials which are suitable as insulation materials from a more general point of view. A good understanding of the coil manufacturing process is needed for this purpose. The second chapter explains the irradiation spectrum seen by the magnets. A third chapter does present the NET/ITER test programme. Step 1 was completed at the end of 1989, the second step will be carried out in the autumn of 1991. Finally, a general assessment of materials and testing methods will be given with recommendations for further testing

  16. Construction of a line for radiation cross-linking of cable insulators at the Kablo Vrchlabi plant

    International Nuclear Information System (INIS)

    Kourim, P.; Zidek, L.; Kopecky, B.

    1983-01-01

    In order to introduce radiation curing into the technology of manufacturing conductors with silicone insulation the suitability was tested of the individual brands of silicone rubber used for cables. The criterion was the range of doses guaranteeing the required mechanical and rheological properties of the rubber. The ELV 1 accelerator was used for irradiation. A description is given of the design of the technological equipment of the line which was put into experimental operation. (J.P.)

  17. Arc tracking energy balance for copper and aluminum aeronautic cables

    International Nuclear Information System (INIS)

    André, T; Valensi, F; Teulet, P; Cressault, Y; Zink, T; Caussé, R

    2017-01-01

    Arc tracking tests have been carried out between two voluntarily damaged aeronautic cables. Copper or aluminum conductors have been exposed to short circuits under alternating current. Various data have been recorded (arc voltage and current, radiated power and ablated mass), enabling to determine a power balance, in which every contribution is estimated. The total power is mainly transferred to the cables (between 50 and 65%, depending on the current and the cable type), and causes the melting and partial vaporization of the metallic core and insulating material, or is conducted or radiated. The other part is deposited into the arc column, being either radiated, convected or conducted. (paper)

  18. Determining Remaining Useful Life of Aging Cables in Nuclear Power Plants - Interim Study FY13

    International Nuclear Information System (INIS)

    Simmons, Kevin L.; Fifield, Leonard S.; Westman, Matthew P.; Ramuhalli, Pradeep; Pardini, Allan F.; Tedeschi, Jonathan R.; Jones, Anthony M.

    2013-01-01

    The most important criterion for cable performance is its ability to withstand a design-basis accident. With nearly 1000 km of power, control, instrumentation, and other cables typically found in an NPP, it would be a significant undertaking to inspect all of the cables. Degradation of the cable jacket, electrical insulation, and other cable components is a key issue that is likely to affect the ability of the currently installed cables to operate safely and reliably for another 20 to 40 years beyond the initial operating life. The development of one or more nondestructive evaluation (NDE) techniques and supporting models that could assist in determining the remaining life expectancy of cables or their current degradation state would be of significant interest. The ability to nondestructively determine material and electrical properties of cable jackets and insulation without disturbing the cables or connections has been deemed essential. Currently, the only technique accepted by industry to measure cable elasticity (the gold standard for determining cable insulation degradation) is the indentation measurement. All other NDE techniques are used to find flaws in the cable and do not provide information to determine the current health or life expectancy. There is no single NDE technique that can satisfy all of the requirements needed for making a life-expectancy determination, but a wide range of methods have been evaluated for use in NPPs as part of a continuous evaluation program. The commonly used methods are indentation and visual inspection, but these are only suitable for easily accessible cables. Several NDE methodologies using electrical techniques are in use today for flaw detection but there are none that can predict the life of a cable. There are, however, several physical and chemical ptoperty changes in cable insulation as a result of thermal and radiation damage. In principle, these properties may be targets for advanced NDE methods to provide early

  19. Simultaneous Thermal and Gamma Radiation Aging of Electrical Cable Polymers

    Energy Technology Data Exchange (ETDEWEB)

    Fifield, Leonard S.

    2018-04-11

    The polymers used for insulation in nuclear power plant electrical cables are susceptible to aging during long term operation. Elevated temperature is the primary contributor to changes in polymer structure that result loss of mechanical and electrical properties, but gamma radiation is also a significant source of degradation for polymers used within relevant plant locations. Despite many years of polymer degradation research, the combined effects of simultaneous exposure to thermal and radiation stress are not well understood. As nuclear operators contemplate and prepare for extended operations beyond initial license periods, a predictive understanding of exposure-based cable material degradation is becoming an increasingly important input to safety, licensing, operations and economic decisions. We are focusing on carefully-controlled simultaneous thermal and gamma radiation accelerating aging and characterization of the most common nuclear cable polymers to understand the relative contributions of temperature, time, dose and dose rate to changes in cable polymer material structure and properties. Improved understanding of cable performance in long term operation will help support continued sustainable nuclear power generation.

  20. Thin film conductors for self-equalizing cables

    Science.gov (United States)

    Owen, G.; Trutna, W. R.; Orsley, T. J.; Lucia, F.; Daly, C. B.

    2017-10-01

    Self-equalizing cables using hollow conductors with wall thickness less than the skin depth were proposed in 1929. However, they do not appear ever to have been widely used, although the idea has resurfaced and been refined from time to time. In the early 2000's, self-equalizing conductors consisting of solid magnetic steel cores coated with silver were developed by W.L. Gore, and used in their 2.5 Gb/s "Eye-Opener" cables, although higher speed versions never appeared. We have revived the original 1929 idea, proposing to use glass as a solid insulating core. This technology can potentially work at frequencies of many 10's of GHz. Possible uses include short range GHz links such as USB and Thunderbolt, and intra-rack interconnections in data centers. Our feasibility experiments have validated the principle. Copper coated glass fibers can, in principle, be manufactured, but in these tests, the conductors were capillaries internally coated with silver as these are easily obtainable, relatively inexpensive and serve to test the concept. The performance of these experimental twin lead cables corresponds to calculations, confirming the general principle. By calculation, we have compared the performance of cables made from copper-on-insulator conductors to that of similar cables made with solid copper conductors, and verified that copper-on-insulator cables have significantly less frequency dependent loss. We have also made and tested cables with copper on PEEK conductors as surrogates for copper on glass fiber.

  1. Development of halogen-free flame-retardant cable for nuclear power plant. 2

    International Nuclear Information System (INIS)

    Matsumoto, Tetsuo; Kimura, Hitoshi; Ishii, Nobuhisa

    1997-01-01

    Halogen-free flame-retardant cables were developed for PWR nuclear power stations. It was confirmed that the developed cables possess flame retardant property, corrosion resistance, low toxicity and low smoke generation, and withstand the normal operation in the environment in PWR containment vessels for 60 years and loss of coolant accident. In the advancement of LWR technology, it is important to improve the reliability of machinery and equipment, to extend the period of continuous operation, to optimize the operation cycle and to improve the maintenance of plants. By improving halogen-free flame-retardant material and applying it to the cables for nuclear power stations, it can contribute to the above purposes. The required characteristics of these cables are explained, and the targets of development are power cables, control cables, instrumentation cables and insulated wires which do not contain halogen. The basic material is polyolefin, in which flame retardant magnesium hydroxide and the agent for improving radiation resistance are mixed. The corrosive property and toxicity of gases, smoke generation and the prevention of spread of flame when the cables burn and the durability in environment were evaluated. (K.I.)

  2. Semiannual report for the period October 1, 1979-March 31, 1980 of work on: (1) superconducting power transmission system development; (2) cable insulation development. Power Transmission Project Technical Note No. 106

    Energy Technology Data Exchange (ETDEWEB)

    1980-07-07

    Progress is reported in a program whose objective is to develop an underground superconducting power transmission system which is economical and technically attractive to the utility industry. The system would be capable of carrying very large blocks of electric power, and would supplant overhead lines in urban and suburban areas and regions of natural beauty. The program consisted initially of work in the laboratory to develop suitable materials, cryostats, and cable concepts. The materials work covers the development and testing of suitable superconductors and dielectric insulation. The laboratory work has now been extended to an outside test facility which represents an intermediate step between the laboratory scale and a full-scale system. The facility will allow cables several hundred feet long to be tested under realistic conditions. In addition, the refrigerator has been designed for optimum service for utility applications.

  3. Determining Remaining Useful Life of Aging Cables in Nuclear Power Plants – Interim Study FY13

    Energy Technology Data Exchange (ETDEWEB)

    Simmons, Kevin L.; Fifield, Leonard S.; Westman, Matthew P.; Ramuhalli, Pradeep; Pardini, Allan F.; Tedeschi, Jonathan R.; Jones, Anthony M.

    2013-09-27

    The most important criterion for cable performance is its ability to withstand a design-basis accident. With nearly 1000 km of power, control, instrumentation, and other cables typically found in an NPP, it would be a significant undertaking to inspect all of the cables. Degradation of the cable jacket, electrical insulation, and other cable components is a key issue that is likely to affect the ability of the currently installed cables to operate safely and reliably for another 20 to 40 years beyond the initial operating life. The development of one or more nondestructive evaluation (NDE) techniques and supporting models that could assist in determining the remaining life expectancy of cables or their current degradation state would be of significant interest. The ability to nondestructively determine material and electrical properties of cable jackets and insulation without disturbing the cables or connections has been deemed essential. Currently, the only technique accepted by industry to measure cable elasticity (the gold standard for determining cable insulation degradation) is the indentation measurement. All other NDE techniques are used to find flaws in the cable and do not provide information to determine the current health or life expectancy. There is no single NDE technique that can satisfy all of the requirements needed for making a life-expectancy determination, but a wide range of methods have been evaluated for use in NPPs as part of a continuous evaluation program. The commonly used methods are indentation and visual inspection, but these are only suitable for easily accessible cables. Several NDE methodologies using electrical techniques are in use today for flaw detection but there are none that can predict the life of a cable. There are, however, several physical and chemical ptoperty changes in cable insulation as a result of thermal and radiation damage. In principle, these properties may be targets for advanced NDE methods to provide early

  4. NRC Information Notice No. 92-01: Cable damage caused by inadequate cable installation procedures and controls

    International Nuclear Information System (INIS)

    Rossi, C.E.

    1993-01-01

    In June 1989, the Tennessee Valley Authority (TVA) removed the cables from a conduit in the reactor protection system of the Watts Bar Nuclear Plant, Unit 2, to inspect for damage. TVA selected this conduit in response to an employee's concern that a welding arc that struck the conduit in response to an employee's concern that a welding arc that struck the conduit during construction may have damaged cables in the conduit. When the cables were removed, TVA found significant damage in the insulation of some cables. This damage was not attributed to heat generated by the alleged welding arc. The damage was principally attributed to the pulling stresses exerted during the initial installation of the cables. Some of the cables had insulation removed down to the conductors. To assess the extent of cable damage and determine the scope of its investigation, TVA removed more cables from conduits that constituted the most difficult pulls (worst case) and found varying degrees of damage that it attributed to pulling stresses. To fill a conduit at Watts Bar, personnel used pull cords to pull more cables through the conduits over the top of existing cables. This practice is called ''pull-by.'' This practice can cause damage to the existing cables from the sawing action of the pull cords and the friction of cables as they are pulled over existing cables. TVA instituted programs to assess the adequacy of cable installation at all its nuclear facilities and take appropriate corrective actions. At Watts Bar, TVA replaced cables in conduits which exceeded a calculated threshold value of side wall bearing pressure (SWBP) and performed a high-potential (hi-pot) tests on a number of other cables in conduits with SWBP below the calculated threshold value

  5. Insulating materials for optoelectronics

    International Nuclear Information System (INIS)

    Agullo-Lopez, F.

    1990-01-01

    Optoelectronics is an interdisciplinary field. Basic functions of an optoelectronic system include the generator of the optical signal, its transmission and handling and, finally, its detection, storage and display. A large variety of semiconductor and insulating materials are used or are being considered to perform those functions. The authors focus on insulating materials, mostly oxides. For signal generation, tunable solid state lasers, either vibronic or those based oon colour centres are briefly described, and their main operating parameters summarized. Reference is made to some developments on fiber and waveguide lasers. Relevant physical features of the silica fibres used for low-loss, long-band, optical transmission are reviewed, as well as present efforts to further reduce attenuation in the mid-infrared range. Particular attention is paid to photorefractive materials (LiNbO 3 , BGO, BSO, etc.), which are being investigated

  6. Condition Monitoring of Cables Task 3 Report: Condition Monitoring Techniques for Electric Cables

    Energy Technology Data Exchange (ETDEWEB)

    Villaran, M.; Lofaro, R.; na

    2009-11-30

    For more than 20 years the NRC has sponsored research studying electric cable aging degradation, condition monitoring, and environmental qualification testing practices for electric cables used in nuclear power plants. This report summarizes several of the most effective and commonly used condition monitoring techniques available to detect damage and measure the extent of degradation in electric cable insulation. The technical basis for each technique is summarized, along with its application, trendability of test data, ease of performing the technique, advantages and limitations, and the usefulness of the test results to characterize and assess the condition of electric cables.

  7. Automation of extrusion of porous cable products based on a digital controller

    Science.gov (United States)

    Chostkovskii, B. K.; Mitroshin, V. N.

    2017-07-01

    This paper presents a new approach to designing an automated system for monitoring and controlling the process of applying porous insulation material on a conductive cable core, which is based on using structurally and parametrically optimized digital controllers of an arbitrary order instead of calculating typical PID controllers using known methods. The digital controller is clocked by signals from the clock length sensor of a measuring wheel, instead of a timer signal, and this provides the robust properties of the system with respect to the changing insulation speed. Digital controller parameters are tuned to provide the operating parameters of the manufactured cable using a simulation model of stochastic extrusion and are minimized by moving a regular simplex in the parameter space of the tuned controller.

  8. NEPO cable system aging management programs

    International Nuclear Information System (INIS)

    Toman, G.

    2002-01-01

    through four steps of aging. The change in individual insulated wires and overall cables can be experienced by the user of the training aids allowing plant cables to be assessed to determine if they are like new or have aged significantly and need to be replaced. If large numbers of cables have aged perceptibly, then more sophisticated condition assessment techniques will be needed to discriminate between degrees of aging to allow planning and scheduling of replacements. The program is both evaluating a number of existing techniques to determine their ease of use and accuracy and is developing a totally new technique based on nuclear magnetic resonance testing. The NMR technique is proving to be easy to perform and interpret and can be performed on as little as 1 mg of material. (author)

  9. Submerged Medium Voltage Cable Systems at Nuclear Power Plants. A Review of Research Efforts Relevant to Aging Mechanisms and Condition Monitoring

    Energy Technology Data Exchange (ETDEWEB)

    Brown, Jason [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Bernstein, Robert [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); White, II, Gregory Von [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Glover, Steven F. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Neely, Jason C. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Pena, Gary [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Williamson, Kenneth Martin [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Zutavern, Fred J. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Gelbard, Fred [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2015-03-01

    In a submerged environment, power cables may experience accelerated insulation degradation due to water - related aging mechanisms . Direct contact with water or moisture intrusion in the cable insulation s ystem has been identified in the literature as a significant aging stressor that can affect performance and lifetime of electric cables . Progressive reduction of the dielectric strength is commonly a result of water treeing which involves the development of permanent hydrophilic structures in the insulation coinciding with the absorption of water into the cable . Water treeing is a phenomenon in which dendritic microvoids are formed in electric cable insulation due to electrochemic al reactions , electromechanical forces , and diffusion of contaminants over time . These reactions are caused by the combined effect s of water presence and high electrical stress es in the material . Water tree growth follow s a tree - like branching pattern , i ncreasing in volume and length over time . Although these cables can be "dried out," water tree degradation , specifically the growth of hydrophilic regions, is believed to be permanent and typically worsens over time. Based on established research , water treeing or water induced damage can occur in a variety of electric cables including XLPE, TR - XLPE and other insulating materials, such as EPR and butyl rubber . Once water trees or water induced damage form, the dielectric strength of an insulation materia l will decrease gradually with time as the water trees grow in length, which could eventually result in failure of the insulating material . Under wet conditions or i n submerged environments , several environmental and operational parameters can influence w ater tree initiation and affect water tree growth . These parameters include voltage cycling, field frequency, temperature, ion concentration and chemistry, type of insula tion material , and the characteristics of its defects. In this effort, a review of academic

  10. Development and characteristics of halogen-free flame-retardant cables for nuclear power plants

    Energy Technology Data Exchange (ETDEWEB)

    Kanemitsuya, K.; Furukawa, K.; Tachibana, T.; Ohara, H.; Ebiike, Y.; Hamachi, K.; Makino, M. (Mitsubishi Cable Industries Ltd., Tokyo (Japan))

    1992-10-01

    Halogen-free flame-retardant (HF-FR) cables for use in nuclear power plants, especially in pressurized water type (PWR) plants, have been developed to advancing the safety and reliability of nuclear power plants. HF-FR cables generate no corrosive gases and minimal amount of toxic gases and smoke during fires, and are accordingly quite safe in comparison with the conventional cables which can cause the secondary calamity by eliminating a large amount of hydrogen halide gas and smoke. HF-FR ethylene-propylene rubber (EPR) and crosslinked polyolefin (XLPO) are used as insulating materials, and HF-FR ethylene-vinyl acetate (EVA) elastomer and polyolefin (PO) are used as jacketing materials. The results of a series of experiments on several types of HF-FR cables have revealed that these cables fully satisfy every requirement, including reliability under LOCA (Loss of Coolant Accidents) simulated conditions, long-term (40y) reliability under thermal and [gamma]-ray exposure, and flame resistivity under vertical tray test (IEEE Std. 383). (author).

  11. Thin film conductors for self-equalizing cables

    Directory of Open Access Journals (Sweden)

    G. Owen

    2017-10-01

    Full Text Available Self-equalizing cables using hollow conductors with wall thickness less than the skin depth were proposed in 1929. However, they do not appear ever to have been widely used, although the idea has resurfaced and been refined from time to time. In the early 2000’s, self-equalizing conductors consisting of solid magnetic steel cores coated with silver were developed by W.L. Gore, and used in their 2.5 Gb/s “Eye-Opener” cables, although higher speed versions never appeared. We have revived the original 1929 idea, proposing to use glass as a solid insulating core. This technology can potentially work at frequencies of many 10’s of GHz. Possible uses include short range GHz links such as USB and Thunderbolt, and intra-rack interconnections in data centers. Our feasibility experiments have validated the principle. Copper coated glass fibers can, in principle, be manufactured, but in these tests, the conductors were capillaries internally coated with silver as these are easily obtainable, relatively inexpensive and serve to test the concept. The performance of these experimental twin lead cables corresponds to calculations, confirming the general principle. By calculation, we have compared the performance of cables made from copper-on-insulator conductors to that of similar cables made with solid copper conductors, and verified that copper-on-insulator cables have significantly less frequency dependent loss. We have also made and tested cables with copper on PEEK conductors as surrogates for copper on glass fiber.

  12. Progress on qualification testing methodology study of electric cables

    International Nuclear Information System (INIS)

    Yoshida, K.; Seguchi, T.; Okada, S.; Ito, M.; Kusama, Y.; Yagi, T.; Yoshikawa, M.

    1983-01-01

    Many instrumental, control and power cables are installed in nuclear power plants, and these cables contain a large amount of organic polymers as insulating and jacketing materials. They are exposed to radiation at high dose rate, steam at high temperature and chemical (or water) spray simultaneously when a LOCA occurs. Under such conditions, the polymers tend to lose their original properties. For reactor safety, the cables should be functional even if they are subjected to a loss-of-coolant accident (LOCA) at the end of their intended service life. In Japan, cable manufacturers qualify their cables according to the proposed test standard issued from IEEJ in 1982, but the standard still has many unsolved problems or uncertainties which have been dealt with tentatively through the manufacturer-user's agreement. The objectives of this research are to study the methodologies for qualification testing of electric wires and cables, and to provide the improved technical bases for modification of the standard. Research activities are divided into the Accident (LOCA) Testing Methodology and the Accelerated Aging Methodology

  13. THE TECHNOLOGICAL AND EXPLOITATIVE FACTORS OF LOCAL INCREASE OF ELECTRIC FIELD STRENGTH IN THE POWER CABLE OF COAXIAL DESIGN

    Directory of Open Access Journals (Sweden)

    G. V. Bezprozvannych

    2016-12-01

    Full Text Available Introduction. Reliability of high voltage power cables in the process of long-term operation is largely due to the intensity of polymeric insulation aging. It is now established that the aging of polyethylene, which is the main material for the insulation of high voltage power cables, under the action of the electric field is determined primarily by the presence of structural heterogeneity arising both during cable production and during use. The cable is always there deviations from the ideal structure, which manifest in a deviation of diameters of conductors from nominal values; in the arrangement of the conductor and the insulation is not strictly coaxially and eccentrically; in elliptic (oval core and insulation; change in relative dielectric constant and thickness of insulation on cable length force the formation of low molecular weight products (including water in the flow at the manufacturing stage crosslinked polyethylene insulation and moisture during operation. Such defects are structural, technological and operational irregularities, which lead to a local change in the electric field. Purpose. Analysis of the influence of the eccentricity, elliptic and spherical inclusions in the electric field distribution in the power cable of a coaxial design with cross-linked polyethylene insulation, based on numerical simulation. Methodology. The bases of the numerical method of calculation of the electrical field strength are Fredholm integral equations of the first and second kind (method of secondary sources for an axially symmetric field. Analysis of the influence of irregularities, including water treeing, the shape of the sounding signal is made using the method of discrete resistive circuit inductance and capacitance of substitution with the initial conditions. Solving systems of linear algebraic equations nodal analysis performed by the sweep method. Results. The presence of the eccentricity and ellipticity in the construction of cable has

  14. New trends in design and fabrication of signal and power cables to increase nuclear safety

    International Nuclear Information System (INIS)

    Salmen, Florin; Florescu, Gheorghe; Ionescu, Aurel

    2007-01-01

    Based on NPP operating experiences in the past, it was found that the inadequate management of aging degradation caused shortening of the lifetime of equipment, which in turn, hindered plant life extension. Aging degradation of plant structures and components should be properly managed to ensure the designated safety function of plant systems during design life and extended life. From a safety perspective, aging management means maintaining the aging degradation level in major equipment and structures below the allowable limit and holding the capacity to sustain abnormal operating condition. Cable aging was not considered as a significant factor in relation to the nuclear power plant maintenance due to its long life which is almost the same as the plant design life. Attempts to extend the lifetime of NPP has become one of the major concern in the nuclear industry world wide. Consequently, life evaluation and lifetime management of cables to survive over 40 years has become major topic of discussion. In connection to this, accelerated aging must be studied in detail in order to simulate the natural aging in NPP. Test results for evaluating aging degradation after accelerated aging of polyethylene jacket will be described herein.There are hundred types of cables in NPPs. These cables can be classified as medium/low voltage cable, low power cable, instrument and control cable, panel connect line cable, special cable, security line cable, phone line cable and ground cable. Insulation and jacket material in electrical cables are fabricated of polymer materials combined with a number of additives and filler to provide the required mechanical, electrical and fire retardant proprieties. The most commonly used insulation materials are XLPE/EPR/EPDM and PVC. PVC has been widely used as an insulation material, particularly in old plants, but it is less used in modern plants. Neoprene/CSPE/PVC are commonly used material for nuclear cable jacket. The old types of cables

  15. Polyethylene as a possible hvdc cable insulant

    Energy Technology Data Exchange (ETDEWEB)

    Hawley, W.G.; Body, R.S.; Mason, J.H.

    1966-10-01

    Many cable authorities have expressed the view that polyethylene would be attractive for this application. The dc conductivity of polyethylene is lower than that of impregnated paper, and varies less with temperature and stress. Polyethylene also has higher thermal conductivity and is resistant to moisture and electrochemical deterioration. Furthermore, processing polyethylene cables should ultimately involve lower capital and manufacturing costs. However, polyethylene has a lower limiting short circuit temperature unless it is cross linked.

  16. Insulation systems for superconducting transmission cables

    DEFF Research Database (Denmark)

    Tønnesen, Ole

    1996-01-01

    the electrical insulation is placed outside both the superconducting tube and the cryostat. The superconducting tube is cooled by liquid nitrogen which is pumped through the hollow part of the tube.2) The cryogenic dielectric design, where the electrical insulation is placed inside the cryostat and thus is kept...

  17. COPPER CABLE RECYCLING TECHNOLOGY

    International Nuclear Information System (INIS)

    Chelsea Hubbard

    2001-01-01

    The United States Department of Energy (DOE) continually seeks safer and more cost-effective technologies for use in deactivation and decommissioning (D and D) of nuclear facilities. The Deactivation and Decommissioning Focus Area (DDFA) of the DOE's Office of Science and Technology (OST) sponsors large-scale demonstration and deployment projects (LSDDPs). At these LSDDPs, developers and vendors of improved or innovative technologies showcase products that are potentially beneficial to the DOE's projects and to others in the D and D community. Benefits sought include decreased health and safety risks to personnel and the environment, increased productivity, and decreased costs of operation. The Idaho National Engineering and Environmental Laboratory (INEEL) generated a list of statements defining specific needs and problems where improved technology could be incorporated into ongoing D and D tasks. One such need is to reduce the volume of waste copper wire and cable generated by D and D. Deactivation and decommissioning activities of nuclear facilities generates hundreds of tons of contaminated copper cable, which are sent to radioactive waste disposal sites. The Copper Cable Recycling Technology separates the clean copper from contaminated insulation and dust materials in these cables. The recovered copper can then be reclaimed and, more importantly, landfill disposal volumes can be reduced. The existing baseline technology for disposing radioactively contaminated cables is to package the cables in wooden storage boxes and dispose of the cables in radioactive waste disposal sites. The Copper Cable Recycling Technology is applicable to facility decommissioning projects at many Department of Energy (DOE) nuclear facilities and commercial nuclear power plants undergoing decommissioning activities. The INEEL Copper Cable Recycling Technology Demonstration investigated the effectiveness and efficiency to recycle 13.5 tons of copper cable. To determine the effectiveness

  18. Ionizing radiation effects on ISS ePTFE jacketed cable assembly

    Science.gov (United States)

    Koontz, S. L.; Golden, J. L.; Lorenz, M. J.; Pedley, M. D.

    2003-09-01

    Polytetrafluoroethylene (PTFE), which is susceptible to embrittlement by ionizing radiation, is used as a primary material in the Mobile Transporter's (MT) Trailing Umbilical System (TUS) cable on the International Space Station (ISS). The TUS cable provides power and data service between the ISS truss and the MT. The TUS cable is normally stowed in an uptake reel and is fed out to follow the MT as it moves along rails on the ISS truss structure. For reliable electrical and mechanical performance, TUS cable polymeric materials must be capable of >3.5% elongation without cracking or breaking. The MT TUS cable operating temperature on ISS is expected to range between -100°C and +130°C. The on-orbit functional life requirement for the MT TUS cable is 10 years. Analysis and testing were performed to verify that the MT TUS cable would be able to meet full-life mechanical and electrical performance requirements, despite progressive embrittlement by the natural ionizing radiation environment. Energetic radiation belt electrons (trapped electrons) are the principal contributor to TUS cable radiation dose. TUS cable specimens were irradiated, in vacuum, with both energetic electrons and gamma rays. Electron beam energy was chosen to minimize charging effects on the non-conductive ePTFE (expanded PTFE) targets. Tensile testing was then performed, over the expected range of operating temperatures, as a function of radiation dose. When compared to the expected in-flight radiation dose/depth profile, atomic oxygen (AO) erosion of the radiation damaged TUS cable jacket surfaces is more rapid than the development of radiation induced embrittlement of the same surfaces. Additionally, the layered construction of the jacket prevents crack growth propagation, leaving the inner layer material compliant with the design elongation requirements. As a result, the TUS cable insulation design was verified to meet performance life requirements.

  19. Design and test of low-capacitance, air-insulated, 80-kV, 0.5-sec source cables for MFTF sustaining-neutral-beam power supples

    International Nuclear Information System (INIS)

    Mayhall, D.J.; Wilson, J.H.; Caldwell, W.J.; Watson, T.F.; Jenkins, J.W. Jr.

    1981-01-01

    The design of air-insulated cables, which meet strict requirements, is described. Inductance, heat transfer, and electrostatic computer codes are used in design. Tests include electric circiut parameters, dc voltage holdoff, impulse voltage holdoff, heat rise at greater than peak duty, and shield mechanical strength

  20. Diffusion and solubility of oxygen in γ-ray irradiated polymer insulation materials

    International Nuclear Information System (INIS)

    Seguchi, Tadao; Yamamoto, Yasuaki.

    1986-03-01

    The effects of 60 Co γ-rays irradiation on diffusion and solubility of oxygen in polymer materials for electric cable insulation materials were investigated. The polymers were polyethylene, ethylene-propylene rubber, chlorinated polyethylene, chlorosulphonated polyethylene, and chloroprene rubber. They were pure grade and several types of formulation grade. The sheets of these polymers were irradiated up to 5 - 200 Mrad under vacuum or in oxygen under pressure of 3 - 15 atm at room temperature or at 70 deg C. By a method of gas desorption, the diffusion coefficient (D) and solubility coefficient (S) of oxygen or argon in polymer materials were determined at various temperatures of 10 - 80 deg C. The D and S decreased with increase of dose, and the decrease by irradiation with oxidation was more remarkable than that by irradiation without oxidation. However, the decreases of D and S by irradiation were reduced by the formulation of polymers. The additives in formulated polymers would reduce the reactions of crosslinking or oxidation by γ-ray irradiation. The activation energy of D was scarcely changed by irradiations with and without oxidation. (author)

  1. Interim report on assessment of cable aging for nuclear power plants

    International Nuclear Information System (INIS)

    2006-12-01

    Research on assessment of cable aging for nuclear power plants (NPPs) started in 2002 in order to obtain data of safety-related cables affected by thermal aging, simultaneous thermal and radiation aging, and Loss-of-Coolant Accident (LOCA) equivalent test, which could contribute to draft guideline on comprehensive assessment of cable aging for NPPs while taking into consideration the latest knowledge. For the cable aging test, cross-linked polyethylene, flame-retardant cross-linked polyethylene, ethylene propylene rubber, flame-retardant ethylene propylene rubber, silicone rubber and special heat-resistant polyvinyl chloride insulators were selected from the safety-related cables used in the nuclear power plants. Furthermore, 2 to 3 kinds of cables with insulators of different manufacturers were added making a total of 14 kinds of cable specimens for the test. Aging period was selected as a basic parameter while three temperature conditions for thermal aging specimen and combined nine conditions of three temperatures with three dose rates for simultaneous aging specimens. Degradation of cable aging was characterized by elongation at break of tensile test. LOCA test for 9 kinds of cables was also conducted using the simultaneous aging specimens. Furthermore, the investigation of applicability of non-destructive degradation diagnostic technologies for aged cables was conducted to confirm the validity of cable aging evaluation at actual operating plants. Interim report was issued in 2006 and based on cable aging test until 21,000 hrs maximum; 1) a significant difference might be observed at times in the aging progress depending on the insulator manufacturer even if the insulator type was identical, 2) activation energy values calculated from the thermal aging test data were smaller than those currently used and principles of calculation and application of the activation energy were developed for evaluation and 3) superposition of time dependent data was applicable to

  2. DC Model Cable under Polarity Inversion and Thermal Gradient: Build-Up of Design-Related Space Charge

    Directory of Open Access Journals (Sweden)

    Nugroho Adi

    2017-07-01

    Full Text Available In the field of energy transport, High-Voltage DC (HVDC technologies are booming at present due to the more flexible power converter solutions along with needs to bring electrical energy from distributed production areas to consumption sites and to strengthen large-scale energy networks. These developments go with challenges in qualifying insulating materials embedded in those systems and in the design of insulations relying on stress distribution. Our purpose in this communication is to illustrate how far the field distribution in DC insulation systems can be anticipated based on conductivity data gathered as a function of temperature and electric field. Transient currents and conductivity estimates as a function of temperature and field were recorded on miniaturized HVDC power cables with construction of 1.5 mm thick crosslinked polyethylene (XLPE insulation. Outputs of the conductivity model are compared to measured field distributions using space charge measurements techniques. It is shown that some features of the field distribution on model cables put under thermal gradient can be anticipated based on conductivity data. However, space charge build-up can induce substantial electric field strengthening when materials are not well controlled.

  3. Correlation of electrical reactor cable failure with materials degradation

    International Nuclear Information System (INIS)

    Stuetzer, O.M.

    1986-03-01

    Complete circuit failure (shortout) of electrical cables typically used in nuclear power plant containments is investigated. Failure modes are correlated with the mechanical deterioration of the elastomeric cable materials. It is found that for normal reactor operation, electrical cables are reliable and safe over very long periods. During high temperature excursions, however, cables pulled across corners under high stress may short out due to conductor creep. Severe cracking will occur in short times during high temperatures (>150 0 C) and in times of the order of years at elevated temperatures (100 0 C to 140 0 C). A theoretical treatment of stress distribution responsible for creep and for cracking by J.E. Reaugh of Science Applications, Inc. is contained in the Appendix. 29 refs., 32 figs

  4. Long-term aging and loss-of-coolant accident (LOCA) testing of electrical cables

    International Nuclear Information System (INIS)

    Nelson, C.F.; Gauthier, G.; Carlin, F.

    1996-10-01

    Experiments were performed to assess the aging degradation and loss-of-coolant accident (LOCA) behavior of electrical cables subjected to long-term aging exposures. Four different cable types were tested in both the U.S. and France: (1) U.S. 2 conductor with ethylene propylene rubber (EPR) insulation and a Hypalon jacket. (2) U.S. 3 conductor with cross-linked polyethylene (XLPE) insulation and a Hypalon jacket. (3) French 3 conductor with EPR insulation and a Hypalon jacket. (4) French coaxial with polyethylene (PE) insulation and a PE jacket. The data represent up to 5 years of simultaneous aging where the cables were exposed to identical aging radiation doses at either 40 degrees C or 70 degrees C; however, the dose rate used for the aging irradiation was varied over a wide range (2-100 Gy/hr). Aging was followed by exposure to simulated French LOCA conditions. Several mechanical, electrical, and physical-chemical condition monitoring techniques were used to investigate the degradation behavior of the cables. All the cables, except for the French PE cable, performed acceptably during the aging and LOCA simulations. In general, cable degradation at a given dose was highest for the lowest dose rate, and the amount of degradation decreased as the dose rate was increased

  5. Insulating materials from renewable raw materials. 3. upd. ed.; Daemmstoffe aus nachwachsenden Rohstoffen

    Energy Technology Data Exchange (ETDEWEB)

    Brandhorst, Joerg; Spritzendorfer, Josef; Gildhorn, Kai; Hemp, Markus

    2009-07-01

    Due to increasing energy prices, obligations to climatic protection and the desire for comfortable, allergy-free living, the thermal insulation is a central question with building and sanitation. Under this aspect, the contribution under consideration describes the very dynamic market of the insulating materials from renewable raw materials and deals with the questions of the users. In particular, the following raw materials are considered in the production of insulating materials: Wood fibre, wood chips, wood wool, sheep wool, flax, hemp, reeds, straw, cellulose.

  6. An update on irradiation of wire and cable

    International Nuclear Information System (INIS)

    Hildreth, N.

    1981-01-01

    Radiation curing with electron accelerators is a growing high technology application in the wire and cable industry. They are used with voltages ranging from 500,000 up to 3,000,000 electron volts. Furthermore new machines are available up to 5.0 MeV. These industrial machines are high powered accelerators which operate continuously between 60 and 75 kilowatts with a few of the new machines operating up to 200 kilowatts. Radiation curing is used as a tool for developing new insulation systems based on low cost materials for applications which previously required the use of expensive fluorocarbon or silicone rubber type insulations. With the development of the larger, more efficient and reliable accelerators and the continuous trend toward developing new insulations designed to fully utilize the potential of radiation chemistry, the authors are confident that industry will continue to be provided with better, lower cost insulation systems

  7. Heat resistant/radiation resistant cable and incore structure test device for FBR type reactor

    International Nuclear Information System (INIS)

    Tanimoto, Hajime; Shiono, Takeo; Sato, Yoshimi; Ito, Kazumi; Sudo, Shigeaki; Saito, Shin-ichi; Mitsui, Hisayasu.

    1995-01-01

    A heat resistant/radiation resistant coaxial cable of the present invention comprises an insulation layer, an outer conductor and a protection cover in this order on an inner conductor, in which the insulation layer comprises thermoplastic polyimide. In the same manner, a heat resistant/radiation resistant power cable has an insulation layer comprising thermoplastic polyimide on a conductor, and is provided with a protection cover comprising braid of alamide fibers at the outer circumference of the insulation layer. An incore structure test device for an FBR type reactor comprises the heat resistant/radiation resistant coaxial cable and/or the power cable. The thermoplastic polyimide can be extrusion molded, and has excellent radiation resistant by the extrusion, as well as has high dielectric withstand voltage, good flexibility and electric characteristics at high temperature. The incore structure test device for the FBR type reactor of the present invention comprising such a cable has excellent reliability and durability. (T.M.)

  8. Elements of a specification for superconducting cable and why they are important for magnet construction

    International Nuclear Information System (INIS)

    Greene, A.F.; Scanlan, R.M.

    1989-01-01

    The purpose of this paper is to point out several features of the specification for SSC superconducting cable and its insulation that are important for fabrication of dipole magnet coils. Among these are the dimensions of the cable and insulation and their relevance for obtaining coils with appropriate overall dimensions, Other important cable properties are related to the twist direction of wire used to fabricate it and the opposite twist (or lay) direction of the cable. For some coils it is easier to work with cable of a particular lay direction. In conjunction with the ease of coil winding comes the requirement in the specification for superconducting cable which restricts the cable surface condition. The ease of winding coils is governed by the ability to bend and twist the cable at the coil ends without having wires come out of place, possibly later leading to insulation damage and a turn-to-turn short. 5 refs., 11 figs., 1 tab

  9. Power cables now and in the future

    Energy Technology Data Exchange (ETDEWEB)

    Wanser, G

    1976-01-01

    A survey is presented of the problems to be faced with the underground supply of electric power to large, urban areas and of the contributions that improvements in power cable technology will make to solving these problems. It is concluded that the increase in population densities and the rising demand for energy on the part of individual consumers bring up problems for electricity supply and thus have a direct influence on development trends in cable engineering. During the last few years the increasing capacities required in power transmission have led to the use of higher voltages and to the application of special methods of cooling for the oil-filled cable. When the technical and economic possibilities with present-day cable techniques have been exhausted, we must anticipate the introduction of new types of cable, i.e., gas-insulated cables and superconducting cables. The problems involved in power distribution are being solved successfully by resorting to larger conductor cross-sectional areas and by raising the voltage levels. The advantages of plastic cables are also being utilized on a wide scale. The requirement that there be freedom from partial discharges in plastic cables operating at medium and higher voltages is becoming increasingly more widely adopted as a new quality criterion in cable engineering. New materials from the polymer range are permitting the introduction of fittings which are easier to install and which reduce costs. Cable engineering has already, to a considerable extent, adapted itself to face future problems. Even so, there are still a large number of problems in cable engineering requiring research, development and operation.

  10. Aging, Loss-of-Coolant Accident (LOCA), and high potential testing of damaged cables

    International Nuclear Information System (INIS)

    Vigil, R.A.; Jacobus, M.J.

    1994-04-01

    Experiments were conducted to assess the effects of high potential testing of cables and to assess the survivability of aged and damaged cables under Loss-of-Coolant Accident (LOCA) conditions. High potential testing at 240 Vdc/mil on undamaged cables suggested that no damage was incurred on the selected virgin cables. During aging and LOCA testing, Okonite ethylene propylene rubber (EPR) cables with a bonded jacket experienced unexpected failures. The failures appear to be primarily related to the level of thermal aging and the presence of a bonded jacket that ages more rapidly than the insulation. For Brand Rex crosslinked polyolefin (XLPO) cables, the results suggest that 7 mils of insulation remaining should give the cables a high probability of surviving accident exposure following aging. The voltage necessary to detect when 7 mils of insulation remain on unaged Brand Rex cables is approximately 35 kVdc. This voltage level would almost certainly be unacceptable to a utility for use as a damage assessment tool. However, additional tests indicated that a 35 kvdc voltage application would not damage virgin Brand Rex cables when tested in water. Although two damaged Rockbestos silicone rubber cables also failed during the accident test, no correlation between failures and level of damage was apparent

  11. Compound deterioration properties of non-halogen flame-resisting cables

    International Nuclear Information System (INIS)

    Yamamoto, Yasuaki; Yagyu, Hideki; Onishi, Takao; Kamiharako, Shinji

    1984-01-01

    Conventional flame-resisting cables release harmful gas such as hydrogen chloride and smoke on burning. To improve this disadvantage, the cables for nuclear power plants using new non-halogen flame-resisting insulating material have been developed. In this experiment, the non-halogen flame-resisting cables were subjected to the environmental test with varying test conditions. The test conditions included the order of exposure (heat treatment, γ-ray irradiation and steam exposure) and dose rate. After the environmental test, the mechanical and electrical properties of the samples were measured. In all test conditions, the samples did not crack in bending, and withstood the bending and withstand-voltage in-water test. The tensile strength and a.c. breakdown voltage did not change, and were stable. The elongation decreased greatly, but maintained the value of about 100 %, and the volumetric resistivity decreased by only one figure. It was confirmed that these cables were able to withstand various environmental tests. (Yoshitake, I.)

  12. Trial manufacture of flame retardant and radiation resistant cables

    Energy Technology Data Exchange (ETDEWEB)

    Oshima, Yunosuke; Hagiwara, Miyuki (Japan Atomic Energy Research Inst., Takasaki, Gunma. Takasaki Radiation Chemistry Research Establishment); Oda, Eisuke

    1983-04-01

    High radiation resistance as well as incombustibility is required for the wires and cables used for nuclear facilities such as nuclear power stations. In order to give such performance to general purpose insulation materials such as ethylene-propylene copolymerized rubber, acenaphthylene bromide condensation product was developed anew. Moreover, by the use of this agent, the new flame retardant and radiation resistant cables were manufactured for trial, which are not different from ordinary plastic rubber cables in the handling such as flexibility, and withstand the radiation nearly up to 1000 Mrad. The requirement for the agent giving flame retardant and radiation resistant properties is explained. The synthesis of acenaphthylene bromide and its condensation product and the effect of giving flame retardant and radiation resistant properties are described. The test resultd of the prevention of spread of flame, the endurance in LOCA-simulating environment, and radiation resistance for the cables manufactured for trial are reported. It was confirmed that the cables of this type are suitable to the use in which the maintenance of mechanical properties after radiation exposure is required.

  13. Correlation of electrical reactor cable failure with materials degradation

    Energy Technology Data Exchange (ETDEWEB)

    Stuetzer, O.M.

    1986-03-01

    Complete circuit failure (shortout) of electrical cables typically used in nuclear power plant containments is investigated. Failure modes are correlated with the mechanical deterioration of the elastomeric cable materials. It is found that for normal reactor operation, electrical cables are reliable and safe over very long periods. During high temperature excursions, however, cables pulled across corners under high stress may short out due to conductor creep. Severe cracking will occur in short times during high temperatures (>150/sup 0/C) and in times of the order of years at elevated temperatures (100/sup 0/C to 140/sup 0/C). A theoretical treatment of stress distribution responsible for creep and for cracking by J.E. Reaugh of Science Applications, Inc. is contained in the Appendix. 29 refs., 32 figs.

  14. Comparison of the burning behaviour of electric cables with intumescent coating in different test methods

    International Nuclear Information System (INIS)

    Will, J.; Hosser, D.

    2000-01-01

    Cables used for electric power and control systems represent a significant potential hazard, particularly in buildings with highly complex wiring. To reduce the risk of ignition and of flame spread and to limit the fire effects, protective intumescent coatings or cables with fire retardant insulation materials have been implemented in safety related areas and locations, particularly of nuclear power plants. Since 1994, extensive experimental research has been performed by iBMB of the Branschweig University of Technology on the burning behaviour of unprotected as well as coated PVC cables. The main goal of this investigations was to develop a qualification method and licensing procedure for cable systems with protective coatings based on realistic fire conditions, which is accepted by the building authorities for application in buildings in general and, in particular, in nuclear power plants. For comparative results of tests with intumescent coatings in different scales - according to the standard IEC 332-3 (large scale), German standard DIN 4102-1 (intermediate scale) and ISO 5660 (small scale) - will be introduced. The setup of the different test procedures and the corresponding phases of natural fires will be discussed. It will be shown that cables with protective coatings are appropriate for fire scenarios up to a developed room fire while only resistance to a local ignition source could be guaranteed by testing according to international or national valid standard. The necessity of testing cables with insulation material, which should guarantee a fire retardant behaviour, by these different methods should be reasonable, because depending on the results of future tests, a more distinguished qualification and application of cables might be possible. (orig.) [de

  15. AN EVALUATION OF CONDITION MONITORING TECHNIQUES FOR LOW-VOLTAGE ELECTRIC CABLES

    International Nuclear Information System (INIS)

    LOFARO, R.J.; GROVE, E.; SOO, P.

    2000-01-01

    Aging of systems and components in nuclear power plants is a well known occurrence that must be managed to ensure the continued safe operation of these plants. Much of the degradation due to aging is controlled through periodic maintenance and/or component replacement. However, there are components that do not receive periodic maintenance or monitoring once they are installed; electric cables are such a component. To provide a means of monitoring the condition of electric cables, research is ongoing to evaluate promising condition monitoring (CM) techniques that can be used in situ to monitor cable condition and predict remaining life. While several techniques are promising, each has limitations that must be considered in its application. This paper discusses the theory behind several of the promising cable CM techniques being studied, along with their effectiveness for monitoring aging degradation in typical cable insulation materials, such as cross-linked polyethylene and ethylene propylene rubber. Successes and limitations of each technique are also presented

  16. Radiation resistance of insulating materials for electric wires

    International Nuclear Information System (INIS)

    Kanemitsuya, Kazuhiko; Okuda, Tomoaki; Tachibana, Tadao; Yagi, Toshiaki; Seguchi, Tadao.

    1990-01-01

    In no halogen incombustible materials, smoke and poisonous gas generation at the time of burning is small, and corrosive gas rarely arises. Since no halogen electric wires and cables which use these material maintain safety for people and equipment in the case of fires, those are used for ships, tunnels, subways and so on. Also in nuclear power stations, the demand for no halogen cables becomes high although the condition of adoption is difficult. In this study, for the purpose of developing the no halogen cables for nuclear power stations, the basic data on the radiation resistance of no halogen incombustible materials were collected, and by using chemical analysis method, the radiation deterioration behavior was examined. The samples were those with base polymers of VLDPE, ULDPE, EEA, EMA and EVA. Gamma ray irradiation, tensile test, chemi-luminescence measurement, and the determination of gel fraction and swelling rate were carried out. The results are reported, In no halogen materials, when ethylene system copolymer is used as the base polymer instead of PE, the composition with good radiation resistance can be obtained, and by combining amine oxidation inhibitor, it is further improved. (K.I.)

  17. Acoustic insulator for combined well equipment of acoustic and radioactivity logging

    International Nuclear Information System (INIS)

    Arkad'ev, E.A.; Gorbachev, Yu.I.; Dseban', I.P.; Yagodov, G.I.

    1977-01-01

    The design of an acoustic insulator for cobined well equipment of acoustic and radioactivity logaing made on the basis of studying the velocity of elastic waves propagation and attenuation in cable structures of various marks is described. It is shown that the cable probe of electric loggign equipment which is recommended as an acoustic insulator for combined well equipment has the necessary sound-insulating properties

  18. Sound cable crossing brings inexpensive electric power to Long Island

    International Nuclear Information System (INIS)

    Grzan, J.; Goyette, R.

    1992-01-01

    This paper reports that while many electric-utility customers in New York State benefit from inexpensive hydroelectric power from Canada and upstate New York, lack of sufficient transmission connections have prevented this electricity from reaching Long Island. However, a newly constructed underground/underwater link capable of carrying 700-MW now transmits low-cost electricity to the island, saving money for customers. The self-contained fluid-filled cable used for the underwater portion of the project is the largest underwater cable in the world. The use of high-pressure, fluid-filled pipe-type cable on the land portion represents the largest application of paper-polypropylene-paper (PPP) insulated cable in the United States. State-of-the-art technologies were implemented in the use of temperature monitoring and leak detection systems, SF 6 gas-insulated substation, and underwater cable laying and embedment techniques

  19. High Voltage Hybrid Electric Propulsion - Multilayered Functional Insulation System (MFIS) NASA-GRC

    Science.gov (United States)

    Lizcano, M.

    2017-01-01

    High power transmission cables pose a key challenge in future Hybrid Electric Propulsion Aircraft. The challenge arises in developing safe transmission lines that can withstand the unique environment found in aircraft while providing megawatts of power. High voltage AC, variable frequency cables do not currently exist and present particular electrical insulation challenges since electrical arcing and high heating are more prevalent at higher voltages and frequencies. Identifying and developing materials that maintain their dielectric properties at high voltage and frequencies is crucial.

  20. Development of non-halogen cables for nuclear power stations

    Energy Technology Data Exchange (ETDEWEB)

    Yagyu, Hideki; Yamamoto, Yasuaki; Onishi, Takao (Hitachi Cable, Ltd., Tokyo (Japan))

    1983-12-01

    The non-halogen fire-resistant cables for nuclear power stations which never generate halogen gas, have been developed. The cables comprise the insulator of EP rubber and the sheath of polyolefine containing non-halogen inorganic fire-retardant. The results of the environmental test and fire-resistance test are described. In the environmental test, the cables were subjected to the heating, gamma-irradiation and steam exposure successively, according to IEEE specification 323,383, and subsequently the change in the appearance, tensile strength and electrical performance of the cables was measured. In the fire-resistance test, the vertical tray fire test according to the IEEE specification 383 was adopted, and other tests including the vertical fire test on insulator cores, oxygen index, the generation of corrosive gas, copper mirror corrosion test, gas toxicity test and optical smoke density test were carried out. It became clear that the cables did not generate halogen gas on burning, and brought about reduced toxicity, corrosion and smoke, and that the safety against fire is greatly improved by using the cables.

  1. Development of non-halogen cables for nuclear power stations

    International Nuclear Information System (INIS)

    Yagyu, Hideki; Yamamoto, Yasuaki; Onishi, Takao

    1983-01-01

    The non-halogen fire-resistant cables for nuclear power stations which never generate halogen gas, have been developed. The cables comprise the insulator of EP rubber and the sheath of polyolefine containing non-halogen inorganic fire-retardant. The results of the environmental test and fire-resistance test are described. In the environmental test, the cables were subjected to the heating, gamma-irradiation and steam exposure successively, according to IEEE specification 323,383, and subsequently the change in the appearance, tensile strength and electrical performance of the cables was measured. In the fire-resistance test, the vertical tray fire test according to the IEEE specification 383 was adopted, and other tests including the vertical fire test on insulator cores, oxygen index, the generation of corrosive gas, copper mirror corrosion test, gas toxicity test and optical smoke density test were carried out. It became clear that the cables did not generate halogen gas on burning, and brought about reduced toxicity, corrosion and smoke, and that the safety against fire is greatly improved by using the cables. (Yoshitake, I.)

  2. Effects of thermal ageing and gamma radiations on ethylene-propylene based insulator of electric cables

    International Nuclear Information System (INIS)

    Baccaro, S.; D'Atanasio, P.

    1986-01-01

    This paper describes the effects of gamma radiation and thermal aging on cable insulator. The elastic properties degrade rapidly as the absorbed dose increases: the percent elongation at break attains nearly 100% value at 0.5 MGy absorbed dose. The gases evolved during the irradiation are mainly H 2 and CO 2 ; CO, CH 4 and C 2 H 6 are present in much lower concentrations. The damage undergone depends strongly on sequential radiation and thermal aging; the analysis of accelerated life test data by means of the Arrhenius model gave (1.23+-0.25) eV for the activation energy, about 1 eV higher than the values reported in the literature

  3. External insulation with cellular plastic materials

    DEFF Research Database (Denmark)

    Sørensen, Lars Schiøtt; Nielsen, Anker

    2014-01-01

    External thermal insulation composite systems (ETICS) can be used as extra insulation of existing buildings. The system can be made of cellular plastic materials or mineral wool. There is a European Technical guideline, ETAG 004, that describe the tests that shall be conducted on such systems....... This paper gives a comparison of systems with mineral wool and cellular plastic, based on experience from practice and literature. It is important to look at the details in the system and at long time stability of the properties such as thermal insulation, moisture and fire. Investigation of fire properties...

  4. Environmental safety providing during heat insulation works and using thermal insulation materials

    Directory of Open Access Journals (Sweden)

    Velichko Evgeny

    2017-01-01

    Full Text Available This article considers the negative effect of thermal insulating materials and products on human health and environment pollution, particularly in terms of the composition of environmentally hazardous construction products. The authors have analyzed the complex measures for providing ecological safety, sanitary and epidemiological requirements, rules and regulations both during thermal insulation works and throughout the following operation of buildings and premises. The article suggests the protective and preventive measures to reduce and eliminate the negative impact of the proceeding of thermal insulation works on the natural environment and on human health.

  5. Positron Annihilation in Insulating Materials

    International Nuclear Information System (INIS)

    Asoka-Kumar, P; Sterne, PA

    2002-01-01

    We describe positron results from a wide range of insulating materials. We have completed positron experiments on a range of zeolite-y samples, KDP crystals, alkali halides and laser damaged SiO 2 . Present theoretical understanding of positron behavior in insulators is incomplete and our combined theoretical and experimental approach is aimed at developing a predictive understanding of positrons and positronium annihilation characteristics in insulators. Results from alkali halides and alkaline-earth halides show that positrons annihilate with only the halide ions, with no apparent contribution from the alkali or alkaline-earth cations. This contradicts the results of our existing theory for metals, which predicts roughly equal annihilation contributions from cation and anion. We also present result obtained using Munich positron microprobe on laser damaged SiO 2 samples

  6. Behaviour of organic materials in radiation environment

    CERN Document Server

    Tavlet, M

    2000-01-01

    Radiation effects in polymers are reminded together with the ageing factors. Radiation-ageing results are mainly discussed about thermosetting insulators, structural composites and cable-insulating materials. Some hints are given about high-voltage insulations, cooling fluids, organic scintillators and light-guides. Some parameters to be taken into account for the estimate of the lifetime of components in radiation environment are also shown. (23 refs).

  7. Development of new radiation resistant, fire-retardant cables

    International Nuclear Information System (INIS)

    Hagiwara, Ko; Morita, Yosuke; Udagawa, Takashi; Fujimura, Shun-ichi; Oda, Eisuke.

    1982-01-01

    For the cables for nuclear facilities, radiation resistance and fire-retardation are severely required. The authors took note of the fact that even in the existing cables for nuclear power plants, their mechanical properties are greatly degraded by the exposure to large dose (for example, 200 Mrad in PWR testing conditions), and attempted the improvement. They employed a new additive, bromated acenaphthylene condensate (con-BACN), which effectively gives radiation resistance and also is a good flame retarder, to be compounded to an insulation material, and examined the characteristics. In this paper, the features of con-BACN and the investigation of fire-retardant EPDM composition are described. As an initial composition, a small amount of zinc white, sulphur, stearic acid, noclac 224 (Ouchi-Shinko Chemicals, Co.), and antimony trioxide, 100 parts of tale and 45 parts of con-BACN were added to 100 parts of EPDM (propylene content 34 %, Japan Synthetic Rubber Co.). As the antiaging agent, it was decided to use phenol series No. 3 as a result of test. The fire-retardant EP rubber-composed cable was produced for trial, its insulation being fabricated, using a Furukawa's pressurized salt bath continuous vulcanizer. The tests of γ-irradiation, simulated LOCA and combustion were carried out, and the test results are reported. It was indicated that the cable resisted against high dose several times as much as 200 Mrad, and was suitable for the applications, in which the mechanical properties such as bending are required to be maintained after radiation exposure. It was also found that con-BACN was safe, and its properties of decomposition, concentration and acute toxicity were all very low. (Wakatsuki, Y.)

  8. Assessment of fibrous insulation materials for the selenide isotope generator system

    International Nuclear Information System (INIS)

    Wei, G.C; Tennery, V.J.

    1977-11-01

    Fibrous insulations for use in the converter and the heat source of the radioisotope-powered, selenide element, thermoelectric generator (selenide isotope generator) are assessed. The most recent system design and material selection basis is presented. Several fibrous insulation materials which have the potential for use as load-bearing or nonload-bearing thermal insulations are reviewed, and thermophysical properties supplied by manufacturers or published in the literature are presented. Potential problems with the application of fibrous insulations in the selenide isotope generator are as follows: compatibility with graphite, the thermoelectric elements, and the isolation hot frame; devitrification, grain growth, and sintering with an accompanying degradation of insulation quality; impurity diffusion from the insulation to adjoining structures; outgassing and storage of fibrous materials. Areas in which thermophysical data or quantitative information on the insulation and structural stability is lacking are identified

  9. Results of radiation tests at cryogenic temperature on some selected organic materials for the LHC

    International Nuclear Information System (INIS)

    Tavlet, M.; Schoenbacher, H.

    1999-01-01

    In the near future, particle accelerators and detectors as well as fusion reactors will operate at cryogenic temperatures. At temperatures as low as 2 K, the organic materials used for the insulation of the superconducting magnets and cables will be exposed to high radiation levels. In this work, a representative selection of organic materials comprising insulating films, cable insulations and epoxy-type-impregnated resins were exposed to neutron and gamma radiation of nuclear reactors, both at ambient and cryogenic temperatures, and were subsequently mechanically tested. The results show that the radiation degradation is never worse in a cryogenic fluid than it is in usual ambient conditions. (author)

  10. Long-term test of the 22.9kV HTS power cable system in LS Cable Ltd

    International Nuclear Information System (INIS)

    Jang, Hyun Man; Lee, Chang Young; Kim, Choon Dong; Kim, Do Hyung; Park, In Son; Ji, Bong Ki; Kim, Dong Wook; Cho, Jeonwook

    2006-01-01

    Since 2001, LS cable Ltd. has been developing the design, manufacturing and evaluation technologies for high temperature superconducting (HTS) power cable system as a member of DAPAS (Dream for Advanced Power system by Applied Superconductivity technology) program in Korea. The 30 m HTS cable system that is rated at 22.9 kV and 1.2 kA giving a rated capacity of 50 MVA had been developed and tested. The cable was designed as a cold dielectric type employing Bi-2223 HTS tapes and polypropylene (PP) laminated paper as the conductor and electrical insulation, respectively. The cable is cooled with sub-cooled liquid nitrogen at temperature from 75 to 77 K. The manufacturing and the installation of the cable system were completed in 2004. Long-term performance test of the cable system has been conducted for six months to verify its electric and mechanical properties in 2005

  11. Estimation of the degradation state of insulated cables by measurement of performance indicators; Estimativa do estado de degradacao de cabos isolados por meio da medicao de indicadores de desempenho

    Energy Technology Data Exchange (ETDEWEB)

    Velasco, Loana [Universidade Federal de Uberlandia (UFU), MG (Brazil). Programa de Pos-Graduacao de Qualidade e Racionalizacao da Energia Eletrica; Freitas, Luiz Carlos de [Universidade Federal de Uberlandia (UFU), MG (Brazil). Fac. de Engenharia Eletrica; Oliveira, Jose Carlos de; Andrade, Darizon de [Universidade Federal de Uberlandia (UFU), MG (Brazil). Dept. de Engenharia Eletrica; Lima, Fernando de; Finazzi, Antonio [Universidade Federal de Mato Grosso (UFMT), Cuiaba, MT (Brazil). Dept. de Engenharia Eletrica

    2011-03-15

    This article presents the development of a prototype that enables the detection of leakage current and operating voltage and allows to employ methods to diagnose the operational state of insulated cables through performance indicators.

  12. Topological insulators/superconductors: Potential future electronic materials

    International Nuclear Information System (INIS)

    Hor, Y. S.

    2014-01-01

    A new material called topological insulator has been discovered and becomes one of the fastest growing field in condensed matter physics. Topological insulator is a new quantum phase of matter which has Dirac-like conductivity on its surface, but bulk insulator through its interior. It is considered a challenging problem for the surface transport measurements because of dominant internal conductance due to imperfections of the existing crystals of topological insulators. By a proper method, the internal bulk conduction can be suppressed in a topological insulator, and permit the detection of the surface currents which is necessary for future fault-tolerant quantum computing applications. Doped topological insulators have depicted a large variety of bulk physical properties ranging from magnetic to superconducting behaviors. By chemical doping, a TI can change into a bulk superconductor. Nb x Bi 2 Se 3 is shown to be a superconductor with T c ∼ 3.2 K, which could be a potential candidate for a topological superconductor

  13. Power cables with extruded insulation and their accessories for rated voltages from 1 kV (Um = 1,2 kV) up to 30 kV (Um = 36 kV) : Part 2: cables for rated voltages from 6 kV (Um = 7,2 kV) up to 30 kV (Um = 36 kV)

    CERN Document Server

    International Electrotechnical Commission. Geneva

    2005-01-01

    Power cables with extruded insulation and their accessories for rated voltages from 1 kV (Um = 1,2 kV) up to 30 kV (Um = 36 kV) : Part 2: cables for rated voltages from 6 kV (Um = 7,2 kV) up to 30 kV (Um = 36 kV)

  14. Tests on irradiated magnet-insulator materials

    International Nuclear Information System (INIS)

    Schmunk, R.E.; Miller, L.G.; Becker, H.

    1983-01-01

    Fusion-reactor coils, located in areas where they will be only partially shielded, must be fabricated from materials which are as resistant to radiation as possible. They will probably incorporate resistive conductors with either water or cryogenic cooling. Inorganic insulators have been recommended for these situations, but the possibility exists that some organic insulators may be usuable as well. Results were previously reported for irradiation and testing of three glass reinforced epoxies: G-7, G-10, and G-11. Thin disks of these materials, nominally 0.5 mm thick by 11.1 mm diameter, were tested in compressive fatigue, a configuration and loading which represents reasonably well the magnet environment. In that work G-10 was shown to withstand repeated loading to moderately high stress levels without failure, and the material survived better at liquid nitrogen temperature than at room temperature

  15. Damages of electrical insulation of cable products used at NPP`s and technique of their detection and operative control; Povrezhdeniya v ehlektricheskoj izolyatsii kabel`nykh izdulij, ehkspluatirue mykh na atomnykh ehlektrostantsiyakh i metody ikh obnaruzheniya i operativnogo kontro lya

    Energy Technology Data Exchange (ETDEWEB)

    Valeev, R S; Filatov, N I

    1994-12-31

    Analysis of possible damages in electrical insulation of cable products under their application at NPP`s is conducted. Basic methods for detecting such damages and rapid control of technical condition of cable products during the operation are considered.

  16. Research on insulating material affecting the property of gas ionization chamber

    International Nuclear Information System (INIS)

    Wang Liqiang; Wang Zhentao; Zheng Jian

    2014-01-01

    The insulating material in ionization chamber affects the internal gas pressure and ionic pulse shape in the research process of the ion drift velocity in high pressure gas ionization chamber. It will affect the ion drift velocity measurement. It is required to isolate by insulating material between electrode to electrode and between electrodes to the shell of gas ionization chamber. Insulating material in gas ionization chamber is indispensable. Therefore it needs to carefully study the insulating material affecting the performance of gas ionization chamber. First of all, it is found that Teflon can slowly adsorb the working gas in ionization chamber, and the gas pressure in it is reduced when we measure the sensitivity of gas ionization chamber over time. It is verified by experiment that insulating materials absorbing and releasing gas is dynamically reversible process. Then the adsorbing gas property of 95% aluminium oxide ceramic and Teflon is studied through experimental comparision. Gas adsorption equilibrium time of ceramic material is faster, generally it is about a few hours, and the gas adsorption capacity is relatively less. Gas adsorption equilibrium time of Teflon is slower, it is about a few days, and the gas adsorption capacity is relatively more. It is found that Teflon will release part of the gas at higher temperature through experimental research on the influence of Teflon adsorbing gas. Finally it is studied that the distribution of insulation in ionization chamber affects the time response speed of ionization chamber by measuring the signal pulse shape of ionization chamber under the pulse X-ray. Through these experimental research, it is presented that it need to pay attention to select insulation material and to design the internal structure and arrangement of insulating material when we design gas ionization chamber. (authors)

  17. Air-Filled Nanopore Based High-Performance Thermal Insulation Materials

    OpenAIRE

    Gangåssæter, Haakon Fossen; Jelle, Bjørn Petter; Alex Mofid, Sohrab; Gao, Tao

    2017-01-01

    State-of-the-art thermal insulation solutions like vacuum insulation panels (VIP) and aerogels have low thermal conductivity, but their drawbacks may make them unable to be the thermal insulation solutions that will revolutionize the building industry regarding energy-efficient building envelopes. Nevertheless, learning from these materials may be crucial to make new and novel high-performance thermal insulation products. This study presents a review on the state-of-the-art air-filled thermal...

  18. Growing and testing mycelium bricks as building insulation materials

    Science.gov (United States)

    Xing, Yangang; Brewer, Matthew; El-Gharabawy, Hoda; Griffith, Gareth; Jones, Phil

    2018-02-01

    In order to improve energy performance of buildings, insulation materials (such as mineral glass and rock wools, or fossil fuel-based plastic foams) are being used in increasing quantities, which may lead to potential problem with materials depletions and landfill disposal. One sustainable solution suggested is the use of bio-based, biodegradable materials. A number of attempts have been made to develop biomaterials, such as sheep wood, hemcrete or recycled papers. In this paper, a novel type of bio insulation materials - mycelium is examined. The aim is to produce mycelium materials that could be used as insulations. The bio-based material was required to have properties that matched existing alternatives, such as expanded polystyrene, in terms of physical and mechanical characteristics but with an enhanced level of biodegradability. The testing data showed mycelium bricks exhibited good thermal performance. Future work is planned to improve growing process and thermal performance of the mycelium bricks.

  19. Reliability studies, construction and test of a pilot cable installation with supra-conductors

    International Nuclear Information System (INIS)

    Franke, H.; Allgemeine Elektricitaets-Gesellschaft AEG Telefunken Kabelwerke A.G., Moenchengladbach; Kabel- und Metallwerke Gutehoffnungshuette A.G., Hannover; Linde A.G., Hoellriegelskreuth

    1980-01-01

    The basic knowledge of electrical insulation, of current carrying capacity of superconductors, of contraction of papers and of thermal insulation was extended. Different kinds of cable-joints were developed. Voltage tests of a testline were made. The line stands the operating voltage, the terminations must be improved to stand the test voltage. The cooling system of a larger cable installation was studied. (orig.) [de

  20. Development of no halogen incombustible cables for atomic energy

    International Nuclear Information System (INIS)

    Ishii, Nobumasa; Kimura, Hitoshi; Fujimura, Shun-ichi

    1990-01-01

    In upgrading light water reactor technology, it is important to improve the reliability of machinery and equipment, to make regular inspection efficient, to extend the period of continuous operation, to optimize operation cycle and to improve the maintainability of plant facilities. For the cables for nuclear power stations, high incombustibility is required, and at present halogen system incombustible materials are used. Recently the development of no halogen incombustible cables has been advanced, with which the generation of corrosive gas and smoke at the time of fires is slight. In this study, the application of such no halogen incombustible cables to nuclear power stations and the improvement of reliability of the cables were investigated. The cables to be developed are those for electric power, control and instrumentation in BWR plants and insulated electric wires. The required characteristics are incombustibility, no generation of smoke and corrosive gas at the time of fires, radiation resistance and steam resistance in LOCA. The selection of base polymers, metal hydrates and radiation protectors, the evaluation of radiation resistance and steam resistance, the examination of the corrosive and poisonous properties of generated gas and smoke generation and so on are reported. The development was successful. (K.I.)

  1. Method and equipment to lead a cable-like material under an irradiation source

    International Nuclear Information System (INIS)

    Riesselmann, F.J.

    1975-01-01

    When irradiating cable-like material (cable jacketed with polyethylene) which is led through an irradiation source and is thus turned and twisted, no uniform irradiation and twist changes have so far been obtained. It is suggested to twist the cable before the first circuit by about 45 0 in one direction, after turning and the second circuit, to twist by about 90 0 in the other direction and to follow with a further two circuits with twisting. A suitable cable twisting device which works with discrete clamping jaw is described in detail. (UWI) [de

  2. Local Thermal Insulating Materials For Thermal Energy Storage ...

    African Journals Online (AJOL)

    Thermal insulation is one of the most important components of a thermal energy storage system. In this paper the thermal properties of selected potential local materials which can be used for high temperature insulation are presented. Thermal properties of seven different samples were measured. Samples consisted of: ...

  3. Partial discharge tests and characterisation of the Advanced Photon Source linac modulator cables

    International Nuclear Information System (INIS)

    Cours, A.

    2007-01-01

    The advanced photon source (APS) linac modulators are PFN-type pulsers with switch-mode charging power supplies (PSs). The PS and the PFN are connected to each other by 15 feet of 100-kV x-ray cable, with the PFN end of the cable terminated with a connector that was confirmed partial-discharge (PD)-free up to 38 kV ac (53.5 kV peak). Another end of the cable is terminated with a connector that was designed by the PS manufacturer and cannot easily be replaced with another type of connector, since part of it is located inside the densely packed PS. PD tests of the cables with this type of connector show that the PD inception voltages (PDIVs) in different cables turn out to be located within a wide voltage range: 21 to 27 kV ac that corresponds to 29 to 38 kV peak. In order to evaluate the insulation condition of the modulator cables, detect insulation deterioration, and ensure failure-preventing equipment maintenance, over the last two years the PDIVs of all high-voltage (HV) cables in use in the modulators have been tested about every three and a half months. Before the tests, all cables were removed from the equipment, carefully cleaned, inspected, and regreased. The tests were performed using a 40-kV PD detector. The test results show that: 1 The PDIVs remain almost unchanged in all tested cables. 2 From test to test, the PDIV of any particular cable may slightly oscillate around some average value. This possibly depends on the connector regreasing technique. 3 There is no direct evidence of cable insulation deterioration during more than two years of operation under voltage higher than the PD inception level.

  4. Cable indenter aging monitor

    International Nuclear Information System (INIS)

    Shook, T.A.; Gardner, J.B.

    1988-07-01

    This project was undertaken to develop a hand-held, nondestructive test device to assess the aged condition of electrical cable by in situ measurement of mechanical properties of polymeric jackets and insulations. The device is an indenter similar to those used to make hardness measurements. Comparison of measurements made on installed cables with previous measurements serving as baseline aging/mechanical property data will determine the state of aging of the field cables. Such a device will be valuable in nuclear and fossil plant life extension programs. Preliminary laboratory tests on cables covered with ethylene propylene rubber (EPR) and chlorosulfated polyethylene (CSPE) point to the measurement of the rate of force increase resulting from constant rate deformation as having the best correlation with progressive thermal aging. This first phase of the work has demonstrated the technical feasibility of the method. A second phase will include the generation of additional groundwork data and the design of the portable indenter for in situ plant measurements

  5. A protocol for lifetime energy and environmental impact assessment of building insulation materials

    International Nuclear Information System (INIS)

    Shrestha, Som S.; Biswas, Kaushik; Desjarlais, Andre O.

    2014-01-01

    This article describes a proposed protocol that is intended to provide a comprehensive list of factors to be considered in evaluating the direct and indirect environmental impacts of building insulation materials, as well as detailed descriptions of standardized calculation methodologies to determine those impacts. The energy and environmental impacts of insulation materials can generally be divided into two categories: (1) direct impact due to the embodied energy of the insulation materials and other factors and (2) indirect or environmental impacts avoided as a result of reduced building energy use due to addition of insulation. Standards and product category rules exist, which provide guidelines about the life cycle assessment (LCA) of materials, including building insulation products. However, critical reviews have suggested that these standards fail to provide complete guidance to LCA studies and suffer from ambiguities regarding the determination of the environmental impacts of building insulation and other products. The focus of the assessment protocol described here is to identify all factors that contribute to the total energy and environmental impacts of different building insulation products and, more importantly, provide standardized determination methods that will allow comparison of different insulation material types. Further, the intent is not to replace current LCA standards but to provide a well-defined, easy-to-use comparison method for insulation materials using existing LCA guidelines. - Highlights: • We proposed a protocol to evaluate the environmental impacts of insulation materials. • The protocol considers all life cycle stages of an insulation material. • Both the direct environmental impacts and the indirect impacts are defined. • Standardized calculation methods for the ‘avoided operational energy’ is defined. • Standardized calculation methods for the ‘avoided environmental impact’ is defined

  6. SCAP: the Nea project on stress corrosion cracking and cable ageing

    International Nuclear Information System (INIS)

    Yamamoto, A.; Huerta, A.; Gott, K.; Koshy, T.

    2007-01-01

    Two subjects - stress corrosion cracking (SCC) and degradation of cable insulation - were selected as the focus of the SCC and Cable Ageing Project (SCAP) due to their relevance for plant ageing assessments and their implication on inspection practices. Fourteen NEA member countries agreed to contribute to the project. The main SCAP objectives are to: establish a complete database with regard to major ageing phenomena for SCC and degradation of cable insulation through collective efforts by OECD/NEA members; establish a knowledge base in these areas by compiling and evaluating the collected data and information systematically; perform an assessment of the data and identify the basis for commendable practices which would help regulators and operators to enhance ageing management. The aim of the knowledge base is to provide a state-of-the-art description of the degradation mechanisms, the main influencing factors, the most susceptible materials and locations, and common strategies available for mitigation and repair. The SCAP project is currently in the development phase, defining and refining the database performance requirements, data format and coding guidelines. The project is scheduled to last four years. It is anticipated that the database definition and the collection of data from member countries will take approximately two years. The subsequent assessment and the commendable practices report are expected to take one year each

  7. Design and testing of low capacitance, 80-kV source cables for MFTF sustaining neutral beam power supplies

    International Nuclear Information System (INIS)

    Mayhall, D.J.; Shimer, D.W.

    1979-01-01

    In this paper we summarize characteristics of several cable configurations and consider one design in detail, which consists of twelve, 250 MCM arc cables, ten 4/0 filament cables, and accel, gradient grid, control, and instrumentation cables within a circular split Al pipe. The pipe is air insulated from an outer 24-in. x 24-in. steel duct by utility pin insulators. Varying run lengths require adjustment of the arc inductance by variation of cross sectional cable position. Equilibrium heat transfer analysis indicates the pulse-off time for source conditioning must be somewhat greater than 60 s to keep conductor temperatures below 90 0 C. The results of a high voltage test of a model cable are presented

  8. Data base of radiation-resistant dielectric and insulating materials

    International Nuclear Information System (INIS)

    Hama, Yoshimasa; Sunazuka, Hideo; Nashiyama, Isamu; Kakuta, Tsunemi.

    1987-01-01

    In the data base of radiation-resistant dielectric and insulating materials, the data format contains such items as to give the summary; the data sheet contains the data in concrete form of respective properties from the references; the sheet of references contains the references in the former two. In the above three, there are attached code No., data sheet No., reference No. and key words. In the three areas as radiation-resistant dielectric and insulating materials, i.e., organic materials, inorganic materials and optical fibers, the following are explained: data format, data sheet and objectives. (Mori, K.)

  9. Development of new radiation resistant, fire-retardant cables. [Gamma radiation

    Energy Technology Data Exchange (ETDEWEB)

    Hagiwara, Ko; Morita, Yosuke; Udagawa, Takashi (Japan Atomic Energy Research Inst., Takasaki, Gunma. Takasaki Radiation Chemistry Research Establishment); Fujimura, Shun-ichi; Oda, Eisuke

    1982-12-01

    For the cables for nuclear facilities, radiation resistance and fire-retardation are severely required. The authors took note of the fact that even in the existing cables for nuclear power plants, their mechanical properties are greatly degraded by the exposure to large dose (for example, 200 Mrad in PWR testing conditions), and attempted the improvement. They employed a new additive, bromated acenaphthylene condensate (con-BACN), which effectively gives radiation resistance and also is a good flame retarder, to be compounded to an insulation material, and examined the characteristics. In this paper, the features of con-BACN and the investigation of fire-retardant EPDM composition are described. As an initial composition, a small amount of zinc white, sulphur, stearic acid, noclac 224 (Ouchi-Shinko Chemicals, Co.), and antimony trioxide, 100 parts of tale and 45 parts of con-BACN were added to 100 parts of EPDM (propylene content 34 %, Japan Synthetic Rubber Co.). As the antiaging agent, it was decided to use phenol series No. 3 as a result of test. The fire-retardant EP rubber-composed cable was produced for trial, its insulation being fabricated, using a Furukawa's pressurized salt bath continuous vulcanizer. The tests of ..gamma..-irradiation, simulated LOCA and combustion were carried out, and the test results are reported. It was indicated that the cable resisted against high dose several times as much as 200 Mrad, and was suitable for the applications, in which the mechanical properties such as bending are required to be maintained after radiation exposure. It was also found that con-BACN was safe, and its properties of decomposition, concentration and acute toxicity were all very low.

  10. Performing of recent real scale cable fire experiments and presentation of the results in the frame of the international collaborative fire modeling project ICFMP. Final report

    International Nuclear Information System (INIS)

    Hosser, Dietmar; Riese, Olaf; Klingenberg, Mark

    2005-01-01

    As a part of the Fire Risk Research Program, the German iBMB (Institut fuer Baustoffe, Massivbau und Brandschutz) of Braunschweig University of Technology and GRS (Gesellschaft fuer Anlagenund Reaktorsicherheit mbH) are participating in an International Collaborative Fire Modeling Project (ICFMP) to assess and validate fire computer codes for nuclear power plant applications. This assessment is being conducted through benchmarking and validation exercises. The tests are simulating cable fires scenarios in a single compartment. The goal of the actual cable fire series is to investigate the effects of a natural fire to vertically routed cables (worst case) with different cable insulation material (PVC and FRNC). Another important aspect of cable fire is the risk of function failure. Therefore in the test series the short circuit and the conduction loss of cables are measured. This report includes a first description of the experimental results for test 1 - test 4 of the International Collaborative Fire Model Project conducted in December 2003 at the iBMB in Germany. The experimental data are reported on the International Collaborative Fire Model Project - Platform. The measured data shall be the basis for fire simulations. The tests show that the FRNC cables have significantly better characteristics in case of fire. No substantial flame spread takes place even in case of preheating. PVC cables could be ignited with a burner output of 50 kW, in contrary, the FRNC cables could be ignited at burner output of 150 kW. The preheating has a complex effect on the fire behavior of the cables. It may occur that gases are pyrolysed which are not ignited during the phase of preheating. These gases are transported from the cable surrounding and may leave the fire room. Short circuits occur first in case ''conductor to conductor'' and later in case ''conductor to tray''. The time periods until short circuits occur are strongly dependent on the preheating of the cables. In case of

  11. Effects evaluation of artificial aging by temperature and gamma radiation on cables for Laguna Verde nuclear power plant (LVNPP)

    Energy Technology Data Exchange (ETDEWEB)

    Vazquez C, R. M.; Bonifacio M, J.; Garcia H, E. E.; Loperena Z, J. A. [ININ, Carretera Mexico-Toluca s/n, 52750 Ocoyoacac, Estado de Mexico (Mexico); Garcia M, C., E-mail: raulmario.vazquez@inin.gob.m [CFE, Central Nuclear Laguna Verde, Km. 42.5 Carretera Cardel-Nautla, Veracruz (Mexico)

    2010-10-15

    A set of tests has been carried out at the Equipment Qualification Laboratory at National Institute of Nuclear Research to perform accelerated aging up to 60 years under temperature and gamma radiation environment for electrical cables. The results obtained from such tests are the base line data for comparison to with the current cable conditions at the plant. This work is intended for establishing the cable aging management program for the Laguna Verde nuclear power plant (LVNPP). For such purpose, the Institute has prepared methodologies and procedures to apply condition monitoring techniques in accelerated aging tests on samples of new cables drawn from the LVNPP warehouse. The condition indicators of the material selected for condition monitoring and the aging management process of cables were: Elongation at Break (EAB) and Oxidation Induction Time (OIT). A cable aging management program includes activities for cable selection, determination of condition indicators of the cable materials (EAB, OIT, Ind enter), accelerated aging of cable samples at the laboratory, analysis of maintenance history, operational experience of the plant and analysis of the environmental and service conditions (temperature and gamma radiation), as well as the establishment of a condition monitoring plan for cables in the plant. Two cable model samples were thermally aged and gamma irradiated with doses corresponding to differential operational periods. EAB and OIT values of cable insulating material (ethylene propylene and cross linked polyethylene) were obtained. It was found that the EAB and OIT data correlation is very closed, and it could be applied to infer values that are not possible to measure directly at the plant and be used for cable aging evaluation and remaining life time determination. (Author)

  12. Copper Cable Recycling Technology. Innovative Technology Summary Report

    International Nuclear Information System (INIS)

    2001-01-01

    The United States Department of Energy (DOE) continually seeks safer and more cost-effective technologies for use in deactivation and decommissioning (D and D) of nuclear facilities. The Deactivation and Decommissioning Focus Area (DDFA) of the DOE's Office of Science and Technology (OST) sponsors large-scale demonstration and deployment projects (LSDDPs). At these LSDDPs, developers and vendors of improved or innovative technologies showcase products that are potentially beneficial to the DOE's projects and to others in the D and D community. Benefits sought include decreased health and safety risks to personnel and the environment, increased productivity, and decreased costs of operation. The Idaho National Engineering and Environmental Laboratory (INEEL) generated a list of statements defining specific needs and problems where improved technology could be incorporated into ongoing D and D tasks. One such need is to reduce the volume of waste copper wire and cable generated by D and D. Deactivation and decommissioning activities of nuclear facilities generates hundreds of tons of contaminated copper cable, which are sent to radioactive waste disposal sites. The Copper Cable Recycling Technology separates the clean copper from contaminated insulation and dust materials in these cables. The recovered copper can then be reclaimed and, more importantly, landfill disposal volumes can be reduced. The existing baseline technology for disposing radioactively contaminated cables is to package the cables in wooden storage boxes and dispose of the cables in radioactive waste disposal sites. The Copper Cable Recycling Technology is applicable to facility decommissioning projects at many Department of Energy (DOE) nuclear facilities and commercial nuclear power plants undergoing decommissioning activities. The INEEL Copper Cable Recycling Technology Demonstration investigated the effectiveness and efficiency to recycle 13.5 tons of copper cable. To determine the effectiveness

  13. Electrically and Thermally Insulated Joint for Liquid Nitrogen Transfer

    DEFF Research Database (Denmark)

    Rasmussen, Carsten; Jensen, Kim Høj; Holbøll, Joachim T.

    1999-01-01

    A prototype of a superconducting cable is currently under construction. The cable conductor is cooled by liquid nitrogen in order to obtain superconductivity. The peripheral cooling circuit is kept at ground potential. This requires a joint which insulates both electrically and thermally...

  14. Standard Practice for Evaluating Thermal Insulation Materials for Use in Solar Collectors

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    1994-01-01

    1.1 This practice sets forth a testing methodology for evaluating the properties of thermal insulation materials to be used in solar collectors with concentration ratios of less than 10. Tests are given herein to evaluate the pH, surface burning characteristics, moisture adsorption, water absorption, thermal resistance, linear shrinkage (or expansion), hot surface performance, and accelerated aging. This practice provides a test for surface burning characteristics but does not provide a methodology for determining combustibility performance of thermal insulation materials. 1.2 The tests shall apply to blanket, rigid board, loose-fill, and foam thermal insulation materials used in solar collectors. Other thermal insulation materials shall be tested in accordance with the provisions set forth herein and should not be excluded from consideration. 1.3 The assumption is made that elevated temperature, moisture, and applied stresses are the primary factors contributing to the degradation of thermal insulation mat...

  15. Hydrogen interactions with silicon-on-insulator materials

    OpenAIRE

    Rivera de Mena, A.J.

    2003-01-01

    The booming of microelectronics in recent decades has been made possible by the excellent properties of the Si/SiO2 interface in oxide on silicon systems.. This semiconductor/insulator combination has proven to be of great value for the semiconductor industry. It has made it possible to continuously increase the number of transistors per chip until the physical limit of integration is now almost reached. Silicon-on-insulator (SOI) materials were early on seen as a step in the logical evolutio...

  16. Basalt fiber insulating material with a mineral binding agent for industrial use

    Science.gov (United States)

    Drozdyuk, T.; Aizenshtadt, A.; Tutygin, A.; Frolova, M.

    2016-04-01

    The paper considers a possibility of using mining industry waste as a binding agent for heat insulating material on the basis of basalt fiber. The main objective of the research is to produce a heat-insulating material to be applied in machine building in high-temperature environments. After synthetic binder having been replaced by a mineral one, an environmentally sound thermal insulating material having desirable heat-protecting ability and not failing when exposed to high temperatures was obtained.

  17. Characterization of dielectric properties of nanocellulose from wood and algae for electrical insulator applications.

    Science.gov (United States)

    Le Bras, David; Strømme, Maria; Mihranyan, Albert

    2015-05-07

    Cellulose is one of the oldest electrically insulating materials used in oil-filled high-power transformers and cables. However, reports on the dielectric properties of nanocellulose for electrical insulator applications are scarce. The aim of this study was to characterize the dielectric properties of two nanocellulose types from wood, viz., nanofibrillated cellulose (NFC), and algae, viz., Cladophora cellulose, for electrical insulator applications. The cellulose materials were characterized with X-ray diffraction, nitrogen gas and moisture sorption isotherms, helium pycnometry, mechanical testing, and dielectric spectroscopy at various relative humidities. The algae nanocellulose sample was more crystalline and had a lower moisture sorption capacity at low and moderate relative humidities, compared to NFC. On the other hand, it was much more porous, which resulted in lower strength and higher dielectric loss than for NFC. It is concluded that the solid-state properties of nanocellulose may have a substantial impact on the dielectric properties of electrical insulator applications.

  18. High power cable with internal water cooling 400 kV

    Science.gov (United States)

    Rasquin, W.; Harjes, B.

    1982-08-01

    Due to the concentration of electricity production in large power plants, the need of higher power transmissions, and the protection of environment, developement of a 400 kV water cooled cable in the power range of 1 to 5 GVA was undertaken. The fabrication and testing of equipment, engineering of cable components, fabrication of a test cable, development of cable terminal laboratory, testing of test cable, field testing of test cable, fabrication of industrial cable laboratory, testing of industrial cable, field testing of industrial cable, and system analysis for optimization were prepared. The field testing was impossible to realize. However, it is proved that a cable consisting of an internal stainless steel water cooled tube, covered by stranded copper profiles, insulated with heavy high quality paper, and protected by an aluminum cover can be produced, withstand tests accordingly to IEC/VDE recommendations, and is able to fulfill all exploitation conditions.

  19. Foam/Aerogel Composite Materials for Thermal and Acoustic Insulation and Cryogen Storage

    Science.gov (United States)

    Williams, Martha K. (Inventor); Smith, Trent M. (Inventor); Fesmire, James E. (Inventor); Weiser, Erik S. (Inventor); Sass, Jared P. (Inventor)

    2011-01-01

    The invention involves composite materials containing a polymer foam and an aerogel. The composite materials have improved thermal insulation ability, good acoustic insulation, and excellent physical mechanical properties. The composite materials can be used, for instance, for heat and acoustic insulation on aircraft, spacecraft, and maritime ships in place of currently used foam panels and other foam products. The materials of the invention can also be used in building construction with their combination of light weight, strength, elasticity, ability to be formed into desired shapes, and superior thermal and acoustic insulation power. The materials have also been found to have utility for storage of cryogens. A cryogenic liquid or gas, such as N.sub.2 or H.sub.2, adsorbs to the surfaces in aerogel particles. Thus, another embodiment of the invention provides a storage vessel for a cryogen.

  20. Recent Advances in the Sound Insulation Properties of Bio-based Materials

    Directory of Open Access Journals (Sweden)

    Xiaodong Zhu

    2013-12-01

    Full Text Available Many bio-based materials, which have lower environmental impact than traditional synthetic materials, show good sound absorbing and sound insulation performances. This review highlights progress in sound transmission properties of bio-based materials and provides a comprehensive account of various multiporous bio-based materials and multilayered structures used in sound absorption and insulation products. Furthermore, principal models of sound transmission are discussed in order to aid in an understanding of sound transmission properties of bio-based materials. In addition, the review presents discussions on the composite structure optimization and future research in using co-extruded wood plastic composite for sound insulation control. This review contributes to the body of knowledge on the sound transmission properties of bio-based materials, provides a better understanding of the models of some multiporous bio-based materials and multilayered structures, and contributes to the wider adoption of bio-based materials as sound absorbers.

  1. Experimental and analytical study of the DC breakdown characteristics of polypropylene laminated paper with a butt gap condition considering the insulation design of superconducting cable

    Science.gov (United States)

    Seo, In-jin; Choi, Won; Seong, Jae-gyu; Lee, Bang-wook; Koo, Ja-yoon

    2014-08-01

    It has been reported that the insulation design under DC stress is considered as one of the critical factors in determining the performance of high-voltage direct current (HVDC) superconducting cable. Therefore, it is fundamentally necessary to investigate the DC breakdown characteristics of the composite insulation system consisting of liquid nitrogen (LN2)/polypropylene-laminated-paper (PPLP). In particular, the insulation characteristics under DC polarity reversal condition should be verified to understand the polarity effect of the DC voltage considering the unexpected incidents taking place at line-commutated-converters (LCC) under service at a DC power grid. In this study, to examine the variation of DC electric field strength, the step voltage and polarity reversal breakdown tests are performed under DC stress. Also, we investigate the electric field distributions in a butt gap of the LN2/PPLP condition considering the DC polarity reversal by using simulation software.

  2. CERTIFICATION OF THE RADIATION RESISTANCE OF COIL INSULATION MATERIAL

    CERN Document Server

    Polinski, J; Bogdan, P

    2013-01-01

    The goal of the WP 7.2.1 sub-task of the EuCARD program has been to determine the Nb$_{3}$Sn based accelerator magnet coil electrical insulation resistance against irradiation, which will occur in future accelerators. The scope of the certification covers determination of mechanical, electrical and thermal properties changes due to irradiation. The report presents a selection of the insulation material candidates for future accelerator magnets as well as the definition of the radiation certification methodology with respect of radiation type, energy, doses and irradiation conditions. The test methods and results of the electrical and mechanical insulation materials properties degradation due to irradiation are presented. Thermal conductivity and Kapitza resistance at temperature range from 1.5 K to 2.0 K (superfluid helium conditions) are given.

  3. Study on condition monitoring techniques for low voltage electrical cables in nuclear power plants

    International Nuclear Information System (INIS)

    Hirao, Hideo; Sakai, Takeshi; Kajimura, Yuusaku

    2017-01-01

    Low voltage electrical cables installed in nuclear power plants are required to maintain its function in a design basis accident environment and they are qualified to that environment. The cables degrade also in normal operating conditions due to ageing and they must maintain integrity until the end of their qualified life. Demands for the condition monitoring technique for low voltage electrical cables have therefore been increasing as nuclear power plants operate longer. A single perfect method for this purpose is not available yet, but the possibility to use two different types of methods which can complement with each other has been examined. The combination of Fourier Transform Infrared Spectroscopy (FT-IR) and Indenter Modulus (IM) method was found highly effective. FT-IR is a method that determines chemical properties (changes in molecular bindings) of cables by using infrared rays, while IM is a method that determines mechanical properties (changes in hardness) of cables by indenters. Both methods are non-destructive and can be applied in-situ to the same material. Reliability of the evaluation can be assured by applying two different types of measurement principles that complement with each other. In this study, various cable samples with different kinds of insulation material (cross-linked polyethylene, ethylene propylene rubber, silicone rubber etc.) were aged with a special accelerated ageing technique which applies simultaneous thermal and radiation ageing to simulate ageing phenomena in a more realistic manner, and the degree of ageing was evaluated with FT-IR and IM. The evaluation result shows good correlation with ageing time and other ageing properties for most material types and the effectiveness of these methods were demonstrated. (author)

  4. Competitive landscape of the EU’s insulation materials industry for energy-efficient buildings

    OpenAIRE

    PAVEL CLAUDIU; BLAGOEVA DARINA

    2017-01-01

    Insulation materials could contribute significantly to improving the overall energy efficiency and sustainability of the buildings, especially by reducing the energy losses through the building envelope (walls, roofs, floors, etc.). The global demand for thermal insulation materials in building applications is projected to increase at a CAGR of 4.5 % between 2016 and 2027. In the EU the demand for thermal insulation materials is estimated at 3.48 % (2015-2027). Wool minerals (glass and stone ...

  5. PRODUCTION OF AN INSULATION MATERIAL FROM CARPET AND BORON WASTES

    Directory of Open Access Journals (Sweden)

    Yasin ERDOĞAN

    2016-12-01

    Full Text Available Buildings are large consumers of energy in all countries. In regions with harsh climatic conditions, a substantial share of energy goes to heat and cool buildings. This paper reports an investigation of the insulation materials made from mixing carpet wastes with a solution with added crude colemanite ore, one of boron minerals, and a solution with added colemanite wastes from a barrage. A new building insulation material was produced which is name, Halibor. Optimum mixing ratios were determined for mass production and the physical properties of the product were established. In addition, the material produced was compared with similar products used in buildings in terms of physical properties. As a result of the investigations, it was established that the product provides high heat and sound insulation and can be used easily in building and construction industry.

  6. FY 2000 research and development of fundamental technologies for AC superconducting power devices. R and D of fundamental technologies for superconducting power cables and faults current limiters, R and D of superconducting magnets for power applications, and study on the total systems and related subjects; 2000 nendo koryu chodendo denryoku kiki kiban gijutsu kenkyu kaihatsu seika hokokusho. Chodendo soden cable kiban gijutsu no kenkyu kaihatsu, chodendo genryuki kiban gijutsu no kenkyu kaihatsu, denryokuyo chodendo magnet no kenkyu kaihatsu, total system nado no kenkyu

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2001-03-01

    The project for research and development of fundamental technologies for AC superconducting power devices has been started, and the FY 2000 results are reported. The R and D of fundamental technologies for superconducting power cables include grasping the mechanical characteristics associated with integration necessary for fabrication of large current capacity and long cables; development of barrier cable materials by various methods; and development of short insulated tubes as cooling technology for long superconducting cables, and grasping its thermal/mechanical characteristics. The R and D of faults current limiters include introduction of the unit for superconducting film fabrication, determination of the structures and layouts for large currents, and improvement of performance of each device for high voltages. R and D of superconducting magnets for power applications include grasping the fundamental characteristics of insulation at cryogenic temperature, completion of the insulation designs for high voltage/current lead bushing, and development of prototype sub-cooled nitrogen cooling unit for cooling each AC power device. Study on the total systems and related subjects include analysis for stabilization of the group model systems, to confirm improved voltage stability when the superconducting cable is in service. (NEDO)

  7. In search of extendable conditions for cable environmental qualification in nuclear power plants

    International Nuclear Information System (INIS)

    Alshaketheep, Tariq; Sekimura, Naoto; Itoi, Tatsuya; Murakami, Kenta

    2016-01-01

    The environmental qualification (EQ) for cable insulators in nuclear power plants (NPPs) has been developed on the basis of the design basis accident (DBA) to prevent reactor core damage. However, the latest safety principles require extending the design concept to prepare the utilized equipment for scenarios after core damage. Thus, we propose a modification to the EQ for cables connecting utilized equipment at design extension conditions. This paper surveys all electrical components for accident management in boiling water reactor-4 (BWR-4), and identifies their connecting cables' functional category as low-voltage power, instrumentation, and control cables. The EQ temperature profile of these cables during the incident phase was addressed for extension. This required postulating maximum temperature environments according to accident scenarios, knowledge of cable integrity degradation, and their current evaluation by the EQ. To evaluate whether these environments are suitable stressors, heat testing was conducted on flame-retardant ethylene propylene rubber (FR-EPR)-insulated cables. On the basis of those results, we suggest a maximum primary peak temperature of the EQ temperature profile of 250degC. We also suggest increasing the primary peak period of the EQ temperature profile to 48 h without experiment, on the basis of inherent excessive margin for mechanical integrity during the ageing phase. (author)

  8. Insulating materials resistance in intense radiation beams

    International Nuclear Information System (INIS)

    Oproiu, Constantin; Martin, Diana; Scarlat, Florin; Timus, Dan; Brasoveanu, Mirela; Nemtanu, Monica

    2002-01-01

    The paper emphasizes the main changes of the mechanical and electrical properties of some organic insulating materials exposed to accelerated electron beams. These materials are liable to be used in nuclear plants and particle accelerators. The principal mechanical and electrical properties analyzed were: tensile strength, fracture strength, tearing on fracture, dielectric strength, electrical resistivity, dielectric constant and tangent angle of dielectric losses. (authors)

  9. Analysis of insulation material deterioration under the LOCA simulated environment on the basis of reaction kinetics

    Energy Technology Data Exchange (ETDEWEB)

    Okada, Sohei; Kusama, Yasuo; Ito, Masayuki; Yagi, Toshiaki; Yoshikawa, Masato (Japan Atomic Energy Research Inst., Takasaki, Gunma. Takasaki Radiation Chemistry Research Establishment)

    1982-12-01

    In the type test of the electric cables installed in reactor containment vessels, it is considerably difficult to perform the testing over a year once in a while to simulate the accidental environment containing radiation and high temperature steam. Two requirements which seem to be more realistic as compared with the above mentioned testing method are inconsistent with each other. To solve this problem, a general rule of deterioration or the expression by an equation is necessary, which enables the extrapolation to show that a short term testing stands on the safety side. The authors have tried to numerically analyze the change of mechanical characteristics of ethylene-propylene rubber (EPR) and Hypalon which are, important as the materials for PH cables (fire-retardant, EP rubber-insulated, chlorosulfonated polyethylene-sheathed cable), in a complex environment of radiation, steam and chemical spray simulating PWR LOCA conditions. In this report, a method is proposed to analyze and estimate the properties by the regression analysis technique on the basis of reaction kinetics, and the analyzed results are described in the order of experiment, analysis method and the results and consideration. The deterioration of the elongation P = e/esub(o) of EPR and Hypalon in the above described complex environment can be represented by the equation - dP/dt = KPsup(n). The exponent n varied in the cases when air is contained or not in that environment, suggesting that the different reactions are dominant in both conditions, respectively. For EPR, n was close to 2 if air was not contained and close to 1 if air was contained in the system.

  10. Design and construction of the mineral insulated magnets

    International Nuclear Information System (INIS)

    Kurokawa, S.; Hirabayashi, H.; Taino, M.; Tsuchiya, K.; Yamamoto, A.

    1978-01-01

    The radiation resistant magnets with mineral insulated coils are designed and constructed. The electrical insulation of the cable is maintained by magnesium oxide in the form of a powder held around the copper hollow conductor by a copper shieth. By the direct water cooling through a hollow conductor the sometimes conflicting requirements of good insulation and high field are fulfilled. The magnets can with stand more than 10 12 rad of absorbed dose. (author)

  11. Survey and evaluation of available thermal insulation materials for use on solar heating and cooling systems

    Energy Technology Data Exchange (ETDEWEB)

    1980-03-01

    This is the final report of a survey and evaluation of insulation materials for use with components of solar heating and cooling systems. The survey was performed by mailing questionnaires to manufacturers of insulation materials and by conducting an extensive literature search to obtain data on relevant properties of various types of insulation materials. The study evaluated insulation materials for active and passive solar heating and cooling systems and for multifunction applications. Primary and secondary considerations for selecting insulation materials for various components of solar heating and cooling systems are presented.

  12. Irradiation effect of the insulating materials for fusion superconducting magnets at cryogenic temperature

    Science.gov (United States)

    Kobayashi, Koji; Akiyama, Yoko; Nishijima, Shigehiro

    2017-09-01

    In ITER, superconducting magnets should be used in such severe environment as high fluence of fast neutron, cryogenic temperature and large electromagnetic forces. Insulating material is one of the most sensitive component to radiation. So radiation resistance on mechanical properties at cryogenic temperature are required for insulating material. The purpose of this study is to evaluate irradiation effect of insulating material at cryogenic temperature by gamma-ray irradiation. Firstly, glass fiber reinforced plastic (GFRP) and hybrid composite were prepared. After irradiation at room temperature (RT) or liquid nitrogen temperature (LNT, 77 K), interlaminar shear strength (ILSS) and glass-transition temperature (Tg) measurement were conducted. It was shown that insulating materials irradiated at room temperature were much degraded than those at cryogenic temperature.

  13. RESEARCHES REGARDING USE OF TEXTILE MATERIALS FOR THERMAL INSULATION AT NEGATIVE TEMPERATURES

    Directory of Open Access Journals (Sweden)

    IOSUB Andrei

    2014-05-01

    Full Text Available Using thermal insulation in negative temperature acts to reduce heat flow to the cooled space or to objects that have a temperature below ambient temperature. To achieve economic operation of the space to be cooled insulation thickness and quality is an important factor. In this article we want to compare three products used in thermal insulation at negative temperatures: expanded polystyrene, non-woven and wool coats. The materials will be tested with a mechanical vapor compression refrigerator capable of producing temperatures in the range +4 .. -35 ° C, managed by a programmer Dixel capable of recording values between +40. .. -60 °C. Refrigeration insulation enclosure was made with 100 mm expanded polystyrene. On one side of the enclosure will be a cut of 250 * 250 mm, chosen in a central position where the material will be introduced to be tested. The dimensions of the samples are 250 * 250 * 60 mm. To check the insulation properties of materials it will be used a temperature logger capable of recording with two probes temperatures between +125...-40° C. One of the probes will be inserted inside the refrigerator and the second probe will be positioned to the outside of the test material adhered to an aluminum plate, in order to read a average temperature. The difference in thickness of the insulation shall be filled with non-woven material. Hardening the assembly will be made using a 6 mm thick OSB board. The materials will be tested in an identical ambient temperature and humidity.

  14. The effect of particulate debris on the insulation integrity of SSC coils during molding and collaring

    International Nuclear Information System (INIS)

    Nehrlich, E.; Markley, F.; Rogers, D.

    1991-03-01

    In order to simulate the effect of accidentally introduced debris on SSC coil insulation integrity, models consisting of two pieces of insulated SSC cable have been loaded in an hydraulic press after introducing foreign particles between the layers. The tests were originally suggested by R. Palmer of the SSC Laboratory. A high voltage (2 Kv) was continually applied between the two cables and the load gradually increased until an electrical short occurred. The high voltage was used as an easy method of detecting insulation punctures and to continue the general type of testing begun at Brookhaven by J. Skaritka, now at the SSC Laboratory, and continued at Fermilab by F. Markley and presented at last year's session of the Conference. A range of particles of different size, shape, and hardness were used, and both conducting and insulating particles were included. Fine wires were also used. When the data are normalized using the control (no particles added), data for each cable batch used, there is a slight correlation between pressure at breakdown and particle size for cables insulated with Kapton only. Adjustment must be made for soft particles that tend to deform and for particles with aspect ratios greater than one. Additional measurements have also been made where the opoxy-fiberglass layer was added to the Kapton insulation overwrap. These show a correlation between conductivity and breakdown pressure. 1 ref., 7 figs

  15. Application of Nanotechnology-Based Thermal Insulation Materials in Building Construction

    Directory of Open Access Journals (Sweden)

    Bozsaky David

    2016-03-01

    Full Text Available Nanotechnology-based materials have previously been used by space research, pharmaceuticals and electronics, but in the last decade several nanotechnology-based thermal insulation materials have appeared in building industry. Nowadays they only feature in a narrow range of practice, but they offer many potential applications. These options are unknown to most architects, who may simply be afraid of these materials owing to the incomplete and often contradictory special literature. Therefore, they are distrustful and prefer to apply the usual and conventional technologies. This article is intended to provide basic information about nanotechnology-based thermal insulation materials for designers. It describes their most important material properties, functional principles, applications, and potential usage options in building construction.

  16. Updated Aging Assessment Approach and Use with Electric Cable Insulation

    International Nuclear Information System (INIS)

    Horvath, David A.; Colaianni, R. Paul

    2003-01-01

    The service life of nuclear power plant equipment may include operation beyond the original design or qualified life. A technical basis is necessary to demonstrate that critical equipment is capable of continued safe operation for any life extension and renewed license term. Such a technical basis is also useful in addressing initial license term aging degradation, age-related failures, and maintenance issues. Early approaches for addressing aging effects developed for environmental qualification programs in the 1980s were incorporated into the Institute of Electrical and Electronic Engineers' (IEEE) IEEE Std. 1205-1993. However, subsequently, a number of events (including promulgation of the Maintenance Renewal Rule, the new License Renewal Rule, and initial plant owner submittals of License Renewal applications) have resulted in improved aging management approaches, which focus on addressing aging effects rather than attempting to identify and mitigate every possible aging mechanism.An example of a major issue facing nuclear power plants as they mature is the general health of the plant electrical cables. This issue came to the forefront as plants began preparing for license renewal, which requires an evaluation of cables to demonstrate that they will perform their function 20 yr beyond the original 40-yr license period. When the two lead plants started preparing for license renewal, there was no generally accepted approach to the bulk evaluation of plant cables, and there were many who thought it not possible to perform a complete plant cable evaluation. The approaches that emerged from the lead plant reviews demonstrated that an assessment of the general health of plant cables could be performed.IEEE's Nuclear Power Engineering Committee recognized the need to capture these improved approaches. A 2 1/2-yr effort of the IEEE Subcommittee-3 Working Group 3.4 culminating in IEEE Std. 1205-2000 is the consensus of representatives from the two lead license renewal

  17. Effect of D.C. testing water tree deteriorated cable and a preliminary evaluation of V.L.F. as alternate

    International Nuclear Information System (INIS)

    Eager, G.S. Jr.; Fryszczyn, B.; Katz, C.; ElBadaly, H.A.; Jean, A.R.

    1992-01-01

    This paper reports that according to the experience of some power utilities, the application of industry recommended high voltage d.c. field tests on 5-35 kV extruded dielectric cables, containing water trees, sometimes causes further deterioration of the insulation. Tests conducted on laboratory aged 15 kV ethylene propylene rubber (EP) and 15 and 28 kV crosslinked polyethylene (XLPE) insulated cables indicate that d.c. proof tests in accordance with AEIC specifications an IEEE test guides without flashover do not appear to cause further deterioration. Depending on the degree of cable aging and the level of test voltage, when flashovers take place, damage may be inflicted to XLPE cables. No damage was observed on aged EP cable, at the same test levels. Because of the aforementioned power utility experience, some users have requested an alternate field proof test. Tests conducted on new XLPE and EP cables indicate that damage to the insulation structure can be detected using VLF (0.1 Hz) voltage at approximately one-third the d.c. voltage level. Field tests conducted on severely tree deteriorated 15 kV polyethylene (PE) cable using AEIC recommended d.c. voltage level of about five times operating voltage level caused cable failure; VLF voltage levels up to two times operating voltage did not. VLF voltage appears to be a suitable alternate to d.c. voltage for field proof testing

  18. PRODUCTION OF AN INSULATION MATERIAL FROM CARPET AND BORON WASTES

    OpenAIRE

    Yasin ERDOĞAN

    2016-01-01

    Buildings are large consumers of energy in all countries. In regions with harsh climatic conditions, a substantial share of energy goes to heat and cool buildings. This paper reports an investigation of the insulation materials made from mixing carpet wastes with a solution with added crude colemanite ore, one of boron minerals, and a solution with added colemanite wastes from a barrage. A new building insulation material was produced which is name, Halibor. Optimum mixing ratios were determi...

  19. Material science experience gained from the space nuclear rocket program: Insulators

    International Nuclear Information System (INIS)

    Wagner, P.

    1992-07-01

    Although Rover reactors are viewed as the ultimate in high-temperature operating systems, many of the materials used in these reactors (for example, support rods, control drums, and the reflector) have to be held at relatively low temperatures while the reactor operates, in order to maintain their structural integrity. Thus the insulators needed to separate these temperature domains are crucial to the reactor's ultimate operating times and temperatures. All of the reactors that were tested used pyrolytic graphite as the primary insulator. However, it had been long planned to replace the graphite with zirconium carbide and a lengthy and intensive effort to develop the zirconium carbide insulators had been made at the time Rover was terminated. This report details research and development and the experience we gained with both these insulator materials

  20. Radiation induced currents in mineral-insulated cables and in pick-up coils: model calculations and experimental verification in the BR1 reactor

    Science.gov (United States)

    Vermeeren, Ludo; Leysen, Willem; Brichard, Benoit

    2018-01-01

    Mineral-insulated (MI) cables and Low-Temperature Co-fired Ceramic (LTCC) magnetic pick-up coils are intended to be installed in various position in ITER. The severe ITER nuclear radiation field is expected to lead to induced currents that could perturb diagnostic measurements. In order to assess this problem and to find mitigation strategies models were developed for the calculation of neutron-and gamma-induced currents in MI cables and in LTCC coils. The models are based on calculations with the MCNPX code, combined with a dedicated model for the drift of electrons stopped in the insulator. The gamma induced currents can be easily calculated with a single coupled photon-electron MCNPX calculation. The prompt neutron induced currents requires only a single coupled neutron-photon-electron MCNPX run. The various delayed neutron contributions require a careful analysis of all possibly relevant neutron-induced reaction paths and a combination of different types of MCNPX calculations. The models were applied for a specific twin-core copper MI cable, for one quad-core copper cable and for silver conductor LTCC coils (one with silver ground plates in order to reduce the currents and one without such silver ground plates). Calculations were performed for irradiation conditions (neutron and gamma spectra and fluxes) in relevant positions in ITER and in the Y3 irradiation channel of the BR1 reactor at SCK•CEN, in which an irradiation test of these four test devices was carried out afterwards. We will present the basic elements of the models and show the results of all relevant partial currents (gamma and neutron induced, prompt and various delayed currents) in BR1-Y3 conditions. Experimental data will be shown and analysed in terms of the respective contributions. The tests were performed at reactor powers of 350 kW and 1 MW, leading to thermal neutron fluxes of 1E11 n/cm2s and 3E11 n/cm2s, respectively. The corresponding total radiation induced currents are ranging from

  1. Problems of increasing specific characteristics of pulse capacitors and cables

    International Nuclear Information System (INIS)

    Kuchinskij, G.S.; Monastyrskij, A.E.; Shilin, O.V.

    1984-01-01

    Requirements for high specific energy are practically related to all types of pulse capacitors of energy storage. At present the specific energy for most types of home and foreign pulse capacitors is about 0.1 MJ/m 3 at operating electric field intensity 70-100 kV/mm. It is shown that the basic means for increasing the specific energy and working intensity is the application of new polymeric film materials. Application of paper-film and film insulation permits to develop the specific types of capacitors designed for a limited service life in an aperiodic discharge mode with lower reliabiliy and the specific energy upto 0.5 MJ/m 3 . Characteristics of separate types of pulse capacitors and cables are given, and reliability criterion is considered. Measures of increasing reliability and service life for pulse capacitors and cables, used as tokamak power supplies are enumerated

  2. Organic Insulation Materials, the Effect on Indoor Humidity, and the Necessity of a Vapor Barrier

    DEFF Research Database (Denmark)

    Rode, Carsten

    1998-01-01

    Examples of organic insulation products are cellulose fiber, other plant fiber, and animal wool. These materials, which are all very hygroscopic, are associated with certain assertions about their building physical behavior that need to be verified.Examples of such assertions are: "A vapor barrier...... is not needed when using organic insulation materials" and "Organic insulation materials have a stabilizing effect on the indoor humidity".The paper presents some numerical analyses of the hygrothermal behavior of wall constructions and the occupied spaces they surround when an organic insulation material...

  3. Electric field analysis of extra high voltage (EHV) underground cables using finite element method

    DEFF Research Database (Denmark)

    Kumar, Mantosh; Bhaskar, Mahajan Sagar; Padmanaban, Sanjeevikumar

    2017-01-01

    used for the insulator due electrical, thermal or environmental stress. Most of these problems are related to the electric field stress on the insulation of the underground cables. The objective of the electric field analysis by using different numerical techniques is to find electric field stress...... electric field stress and other parameters of EHV underground cables with given boundary conditions using 2-D electric field analysis software package (IES-ELECTRO module) which is based on the finite element method (FEM).......Transmission and Distribution of electric power through underground cables is a viable alternative to overhead lines, particularly in residential or highly populated areas. The electrical stresses are consequences of regular voltages and over voltages and the thermal stresses are related to heat...

  4. Bio-susceptibility of materials and thermal insulation systems used for historical buildings

    Science.gov (United States)

    Sterflinger, Katja; Ettenauer, Joerg; Pinar, Guadalupe

    2013-04-01

    In historical buildings of Northern countries high levels of energy are necessary to reach comfortable temperatures especially during the cold season. For this reason historical buildings are now also included in country specific regulations and ordinances to enhance the "energy - efficiency". Since an exterior insulation - as it is commonly used for modern architecture - is incompatible with monument protection, several indoor insulation systems based on historical and ecological materials, are on the market that should improve the thermic performance of a historical building. However, using organic materials as cellulose, loam, weed or wood, bears the risk of fungal growth and thus may lead to health problems in indoor environments. For this reason 5 different ecological indoor insulations systems were tested for their bio-susceptibility against various fungi both under natural conditions - after 2 years of installation in an historical building - and under laboratory conditions with high levels of relative humidity. Fungal growth was evaluated by classical isolation and cultivation as well as by molecular methods. The materials turned out to have a quite different susceptibility towards fungal contamination. Whereas insulations made of bloated Perlite (plaster and board) did not show any fungal growth after 2 years of exposition, the historical insulation made of loam and weed had high cell counts of various fungi. In laboratory experiments wooden softboard represented the best environment for fungal growth. As a result from this study, plaster and board made of bloated Perlite are presented as being the most appropriate materials for thermal insulation at least from the microbiological and hygienic point of view. For future investigations and for the monitoring of fungi in insulation and other building materials we suggest a molecular biology approach with a common protocol for quantitative DNA-extraction and amplification.

  5. ELECTROMECHANICAL TRANSIENT PROCESSES DURING SUPPLY VOLTAGE CHANGING IN THE SYSTEM OF POLYMER INSULATION COVERING OF THE CURRENT-CARRYING CORE OF ULTRA HIGH VOLTAGE CABLES

    Directory of Open Access Journals (Sweden)

    V. M. Zolotaryov

    2018-04-01

    Full Text Available Aim. The article is devoted to the analysis of the electromechanical transient processes in a system of three frequency-controlled electric drives based on asynchronous motors that control current-carrying core motion, as well as to the study of the effect of such processes on the modes applying three-layer polymer insulation to the current-carrying core. Technique. The study was conducted based on the concepts of electromechanics, electromagnetic field theory, mathematical physics, mathematical modeling. Results. A mathematical model has been developed to analyze transients in an electromechanical system consisting of three frequency-controlled electric drives providing current-carrying core motion of ultra-high voltage cables in an inclined extrusion line. The coordination of the electromechanical parameters of the system drives has been carried out and the permissible changes in the supply voltage at the limiting mass while moving current-carrying core of ultra-high voltage cables with applied polymer insulation have been estimated. Scientific novelty. For the first time it is determined that with the limiting mass of the current-carrying core, the electromechanical system allows to stabilize the current-carrying core speed with the required accuracy at short-term decreases in the supply voltage by no more than 27 % of its amplitude value. It is also shown that this system is resistant to short-term increases in voltage by 32 % for 0.2 s. Practical significance. Using the developed model, it is possible to calculate the change in the configuration and speed of the slack current-carrying core when applying polymer insulation, depending on the specific mass of the current-carrying core per unit length, its tension at the bottom, the torque of the traction motor and the supply voltage to achieve stable operation of the system and accurate working of the set parameters.

  6. Assessment of NDE for key indicators of aging cables in nuclear power plants - Interim status

    Science.gov (United States)

    Glass, S. W.; Ramuhalli, P.; Fifield, L. S.; Prowant, M. S.; Dib, G.; Tedeschi, J. R.; Suter, J. D.; Jones, A. M.; Good, M. S.; Pardini, A. F.; Hartman, T. S.

    2016-02-01

    Degradation of the cable jacket, electrical insulation, and other cable components of installed cables within nuclear power plants (NPPs) is known to occur as a function of age, temperature, radiation, and other environmental factors. System tests verify cable function under normal loads; however, the concern is over cable performance under exceptional loads associated with design-basis events (DBEs). The cable's ability to perform safely over the initial 40-year planned and licensed life has generally been demonstrated and there have been very few age-related cable failures. With greater than 1000 km of power, control, instrumentation, and other cables typically found in an NPP, replacing all the cables would be a severe cost burden. Justification for life extension to 60 and 80 years requires a cable aging management program to justify cable performance under normal operation as well as accident conditions. Currently the gold standard for determining cable insulation degradation is the elongation-at-break (EAB). This, however, is an ex-situ measurement and requires removal of a sample for laboratory investigation. A reliable nondestructive examination (NDE) in-situ approach is desirable to objectively determine the suitability of the cable for service. A variety of tests are available to assess various aspects of electrical and mechanical cable performance, but none of these tests are suitable for all cable configurations nor does any single test confirm all features of interest. Nevertheless, the complete collection of test possibilities offers a powerful range of tools to assure the integrity of critical cables. Licensees and regulators have settled on a practical program to justify continued operation based on condition monitoring of a lead sample set of cables where test data is tracked in a database and the required test data are continually adjusted based on plant and fleet-wide experience. As part of the Light Water Reactor Sustainability program sponsored

  7. A 40 kA NbTi cable in conduit conductor for the large poloidal field coils of net

    International Nuclear Information System (INIS)

    Torossian, A.; Bessette, D.; Turck, B.; Kazimierzak, B.

    1990-01-01

    The main feature of this cable in conduit design is to separate the manufacture of the full length of the steel conduit (400 m) and of the cable in order to minimize the industrial risk and consequently the cost. A circular cross section for that cable seems to be the most suitable for that purpose: - axisymmetric cabling with full transposition of strands, - cable behaviour independent of the field orientation, - less deformation of subcables, - cross section remains circular when the cable is under tension and makes the slippage of the cable in the conduit easier, - butt welding of 8 m long tubes forming the conduit becomes simpler. The square external shape allows to minimize the amount of insulating material and consequently improves the overall current density of the coil. This conductor is aimed to large poloidal field coils for NET which do not require high field and in that case NbTi seems to be the best choice with regard to reliability and cost but Nb 3 Sn could be used as well. Stainless steel ribbons are inserted between subcables in order to reduce losses induced by the rapid field changes and also to improve the mechanical behaviour of the cable

  8. Overview of thermal conductivity models of anisotropic thermal insulation materials

    Science.gov (United States)

    Skurikhin, A. V.; Kostanovsky, A. V.

    2017-11-01

    Currently, the most of existing materials and substances under elaboration are anisotropic. It makes certain difficulties in the study of heat transfer process. Thermal conductivity of the materials can be characterized by tensor of the second order. Also, the parallelism between the temperature gradient vector and the density of heat flow vector is violated in anisotropic thermal insulation materials (TIM). One of the most famous TIM is a family of integrated thermal insulation refractory material («ITIRM»). The main component ensuring its properties is the «inflated» vermiculite. Natural mineral vermiculite is ground into powder state, fired by gas burner for dehydration, and its precipitate is then compressed. The key feature of thus treated batch of vermiculite is a package structure. The properties of the material lead to a slow heating of manufactured products due to low absorption and high radiation reflection. The maximum of reflection function is referred to infrared spectral region. A review of current models of heat propagation in anisotropic thermal insulation materials is carried out, as well as analysis of their thermal and optical properties. A theoretical model, which allows to determine the heat conductivity «ITIRM», can be useful in the study of thermal characteristics such as specific heat capacity, temperature conductivity, and others. Materials as «ITIRM» can be used in the metallurgy industry, thermal energy and nuclear power-engineering.

  9. Test results for cables used in nuclear power plants by a new environmental testing method

    Energy Technology Data Exchange (ETDEWEB)

    Handa, Katsue; Fujimura, Shun-ichi; Hayashi, Toshiyasu; Takano, Keiji; Oya, Shingo

    1982-12-01

    In the nuclear power plants using PWRs or BWRs in Japan, environmental tests are provided, in which simulated LOCA conditions are considered so as to conform with Japanese conditions, and many cables which passed these tests are presently employed. Lately, the new environmental testing, in which a credible accident called MSLB (main steam line breakage) is taken into account, is investigated in PWR nuclear power plants, besides LOCA. This paper reports on the results of evaluating some PWR cables for this new environmental testing conditions. The several cables tested were selected out of PH cables (fire-retardant, ethylene propylene rubber insulated, chlorosulfonated polyethylene sheathed cables) as the cables for safety protecting circuits and to be used in containment vessels where the cables are to be exposed to severe environmental test conditions of 2 x 10/sup 8/ Rad ..gamma..-irradiation and simulated LOCA. All these cables have been accepted after the vertical tray burning test provided in the IEEE Standard 383. The new testing was carried out by sequentially applying thermal deterioration, ..gamma..-irradiation, and the exposure to steam (twice 300 s exposures to 190 deg C superheated steam). After completing each step, tensile strength, elongation, insulation resistance and breakdown voltage were measured, respectively. Every cable tested showed satisfactory breakdown voltage after the exposure to steam, thus it was decided to be acceptable. In future, it is required to investigate the influence of the rate of temperature rise on the cable to be tested in MSLB simulation.

  10. Effects of gamma-rays irradiation on tracking resistance of organic insulating materials

    Energy Technology Data Exchange (ETDEWEB)

    Du, Boxue; Suzuki, Akio; Kobayashi, Shigeo [Tokyo Univ. of Agriculture and Technology, Koganei (Japan). Faculty of Technology

    1996-04-01

    This paper describes the influence of gamma-rays irradiation on tracking failure of organic insulating materials by use of the IEC Publ.112 method. Tracking resistance of organic insulating materials under wet polluted condition has been studied by many investigators with a test method of the IEC Publ.112. The investigations on irradiation effects on tracking resistance should be enhanced due to the increasing usage of organic insulating materials in the radiation environments. The tracking resistance seems to be affected by gamma-irradiation, but the knowledge on the influence of gamma-irradiation is quite a few and systematic studies are needed. In this paper, modified polyphenylene oxide, polybutylene naphthalate, modified polycarbonate and polybutylene terephthalate which were irradiated in air until 1x10{sup 7}R and 1x10{sup 8}R with dose rate of 10{sup 6}R/hr using {sup 60}Co gamma-source have been employed. The total dose effects on the number of drops to tracking failure, contact angle and charges of scintillation have been studied. As the total doses are increased, the number of drops to tracking failure decreases with polybutylene terephthalate. On the other hand, the number of drops to tracking failure increases with polybutylene naphthalate and modified polycarbonate when the total doses are increased. The effects of gamma-rays irradiation on tracking failure are due to radiation-induced degradation or cross-linking of organic insulating materials. When the organic insulating materials are degraded by gamma-irradiation, the tracking resistance decreases, but for cross-linking type materials, the tracking resistance increases. (author)

  11. Safety distance for preventing hot particle ignition of building insulation materials

    OpenAIRE

    Jiayun Song; Supan Wang; Haixiang Chen

    2014-01-01

    Trajectories of flying hot particles were predicted in this work, and the temperatures during the movement were also calculated. Once the particle temperature decreased to the critical temperature for a hot particle to ignite building insulation materials, which was predicted by hot-spot ignition theory, the distance particle traveled was determined as the minimum safety distance for preventing the ignition of building insulation materials by hot particles. The results showed that for sphere ...

  12. A novel extrusion head for the renovation of cable sheaths - numeric simulation speeds conceptual work; Une tete d'extrusion novatrice pour revetir des cables. La simulation numerique pour accelerer sa conception

    Energy Technology Data Exchange (ETDEWEB)

    Ata-Caesar, D.; Gendre, F.; Schillaci, J.

    2005-07-01

    This article describes a new method of applying layers of insulation to power cables. The disadvantages of traditional methods of extrusion of cable insulation are looked at, that often are a source of impurities that can possibly degrade the physical and chemical qualities of the end product. The article discusses how the new method was developed in co-operation with a specialised University of Applied Science. Also, the savings in time and money that can be made during the optimisation of a prototype are discussed. The numeric simulation methods used are examined and the commercialisation of the product is looked at.

  13. Materials, Strands, and Cables for Superconducting Accelerator Magnets. Final Report

    Energy Technology Data Exchange (ETDEWEB)

    Sumption, Mike D. [Ohio State University, Columbia, OH (United States); Collings, Edward W. [Ohio State University, Columbia, OH (United States)

    2014-09-19

    This report focuses on Materials, Strands and Cables for High Energy Physics Particle accelerators. In the materials area, work has included studies of basic reactions, diffusion, transformations, and phase assemblage of Nb3Sn. These materials science aspects have been married to results, in the form of flux pinning, Bc2, Birr, and transport Jc, with an emphasis on obtaining the needed Jc for HEP needs. Attention has also been paid to the “intermediate-temperature superconductor”, magnesium diboride emphasis being placed on (i) irreversibility field enhancement, (ii) critical current density and flux pinning, and (iii) connectivity. We also report on studies of Bi-2212. The second area of the program has been in the area of “Strands” in which, aside from the materials aspect of the conductor, its physical properties and their influence on performance have been studied. Much of this work has been in the area of magnetization estimation and flux jump calculation and control. One of the areas of this work was strand instabilities in high-performance Nb3Sn conductors due to combined fields and currents. Additionally, we investigated quench and thermal propagation in YBCO coated conductors at low temperatures and high fields. The last section, “Cables”, focussed on interstrand contact resistance, ICR, it origins, control, and implications. Following on from earlier work in NbTi, the present work in Nb3Sn has aimed to make ICR intermediate between the two extremes of too little contact (no current sharing) and too much (large and unacceptable magnetization and associated beam de-focussing). Interstrand contact and current sharing measurements are being made on YBCO based Roebel cables using transport current methods. Finally, quench was investigated for YBCO cables and the magnets wound from them, presently with a focus on 50 T solenoids for muon collider applications.

  14. Simulation of energy- efficient building prototype using different insulating materials

    Science.gov (United States)

    Ouhaibi, Salma; Belouaggadia, Naoual; Lbibb, Rachid; Ezzine, Mohammed

    2018-05-01

    The objective of this work is to analyze the energetic efficiency of an individual building including an area of 130 m2 multi-zone, located in the region of FEZ which is characterized by a very hot and dry climate in summer and a quite cold one in winter, by incorporating insulating materials. This study was performed using TRNSYS V16 simulation software during a typical year of the FEZ region. Our simulation consists in developing a comparative study of two types of polystyrene and silica-aerogel insulation materials, in order to determine the best thermal performance. The results show that the thermal insulation of the building envelope is among the most effective solutions that give a significant reduction in energy requirements. Similarly, the use of silica-aerogels gives a good thermal performance, and therefore a good energy gain.

  15. Investigation of the Hygrothermal Performance of Alternative Insulation Materials

    DEFF Research Database (Denmark)

    Rode, Carsten; Kristiansen, Finn Harken; Rasmussen, Niels T.

    1999-01-01

    The paper gives an account of hygrothermal investigations carried out on some insulation products which are "alternative" to the ones that are traditionally used in Danish constructions. The alternative products are claimed to be friendly both to the environment and to the labour force. The mater......The paper gives an account of hygrothermal investigations carried out on some insulation products which are "alternative" to the ones that are traditionally used in Danish constructions. The alternative products are claimed to be friendly both to the environment and to the labour force...... is determined for the different materials with a guarded hot plate apparatus in which different vapour pressure conditions can be maintained over the specimens. The apparatus and some results are presented.2. Computational analysis of the hygrothermal performance of constructions with alternative insulation...... products.The hygrothermal performance of constructions with alternative insulation products is analysed with a computational model for combined heat and moisture transfer. The analysis concerns both traditional wall and roof constructions with the alternative insulation products, and some alternative...

  16. Sistema de prueba para la determinación de la capacitancia y permitividad relativa en cables de bajo voltaje del tipo TW y THW

    Directory of Open Access Journals (Sweden)

    Juan Almirall Mesa

    2011-02-01

    Full Text Available En los cables de baja tensión la comprobación de la calidad del material aislante de recubrimiento seefectúa a partir de la evaluación de parámetros eléctricos tales como: la resistencia de aislamiento y lacapacitancia del mismo. En el presente trabajo se expone el esquema de prueba, su calibración y elanálisis de la metodología de ensayo empleada, para medir la capacitancia de cables nacionales del tipoTW y THW. El esquema general de pruebas consta de dos partes fundamentales: el sistema de pruebapara la medición de los parámetros eléctricos y el sistema de control de temperatura y de nivel del líquidodonde se sumergen los cables para los ensayos, este último garantiza que los cambios de temperaturaen el mismo se mantengan en el rango establecido por las normas. La metodología tiene en cuenta ladeterminación del efecto que tienen las condiciones iniciales sobre los resultados finales.  The verification of the quality of the covering insulating material in low voltage cables is carried outbeginning whit the evaluation of electric parameters such as: insulating resistance and capacitance of thesame. In this work, the test scheme, its calibration and the analyses of the methodology of the employedtest, for measuring the national cables capacitance of the TW and THW type are exposed. The generalscheme of test consist in two fundamental parts: the test system for the measure of the electric parametersand the temperature and liquid level control system where the cables are immersed for the test, the lastsystem guarantee that the temperature changes in the same in the establish range by the standards aremaintained.The methodology taking into account the determination of the effect that has the startingconditions on the final results.

  17. Investigation of Insulation Materials for Future Radioisotope Power Systems

    Science.gov (United States)

    Cornell, Peggy A.; Hurwitz, Frances I.; Ellis, David L.; Schmitz, Paul C.

    2013-01-01

    NASA's Radioisotope Power Systems (RPS) Technology Advancement Project is developing next generation high-temperature insulation materials that directly benefit thermal management and improve performance of RPS for future science missions. Preliminary studies on the use of multilayer insulation (MLI) for Stirling convertors used on the Advanced Stirling Radioisotope Generator (ASRG) have shown the potential benefits of MLI for space vacuum applications in reducing generator size and increasing specific power (W/kg) as compared to the baseline Microtherm HT (Microtherm, Inc.) insulation. Further studies are currently being conducted at NASA Glenn Research Center on candidate MLI foils and aerogel composite spacers. This paper presents the method of testing of foils and spacers and experimental results to date.

  18. Plasma immersion ion implantation into insulating materials

    International Nuclear Information System (INIS)

    Tian Xiubo; Yang Shiqin

    2006-01-01

    Plasma immersion ion implantation (PIII) is an effective surface modification tool. During PIII processes, the objects to be treated are immersed in plasmas and then biased to negative potential. Consequently the plasma sheath forms and ion implantation may be performed. The pre-requirement of plasma implantation is that the object is conductive. So it seems difficult to treat the insulating materials. The paper focuses on the possibilities of plasma implantation into insulting materials and presents some examples. (authors)

  19. Remaining life prediction of I and C cables for reliability assessment of NPP systems

    International Nuclear Information System (INIS)

    Santhosh, T.V.; Ghosh, A.K.; Fernandes, B.G.

    2012-01-01

    Highlights: ► A framework for time dependent reliability prediction of I and C cables for use in PSA of NPP has been developed using stress–strength interference theory. ► The proposed methodology has been illustrated with the accelerated thermal aging data on a typical XLPE cable. ► The behavior of insulation resistance when the degradation process is linear or exponential has also been modeled. ► The reliability index or probability of failure obtained from this approach can be used in system reliability evaluation to account for cable aging for PSA of NPP. - Abstract: Instrumentation and control (I and C) cables are one of the most important components in nuclear power plants (NPPs) because they provide power to safety-related equipment and also to transmit signals to and from various controllers to perform safety operations. I and C cables in NPP are subjected to a variety of aging and degradation stressors that can produce immediate degradation or aging-related mechanisms causing the degradation of cable components over time. Although, there exits several life estimation techniques, currently there is no any standard methodology or an approach toward estimating the time dependent reliability of I and C cables that can be directly used in probabilistic safety assessment (PSA) applications. Hence, the objective of this study is to develop an approach to estimate and confirm the continued acceptable margin in cable insulation life over time subjected to aging. This paper presents a framework based on the structural reliability theory to quantify the life time of I and C cable subjecting to thermal aging. Since cross-linked polyethylene (XLPE) cables are extensively being used in Indian NPPs, the remaining life time evaluations have been carried out for a typical XLPE cable. However, the methodology can be extended to other cables such as polyvinyl chloride (PVC), ethylene propylene rubber (EPR), etc.

  20. Analysis of the electrodynamics of subcable current distribution in the superconducting POLO coil cable

    International Nuclear Information System (INIS)

    Sihler, C.; Heller, R.; Maurer, W.; Ulbricht, A.; Wuechner, F.

    1995-10-01

    Unexpected ramp rate limitations (RRL) found in superconducting magnets during the development of magnet systems can be attributed to a current imbalance amongst the cabled strands which leads to a lower than expected quench current. In superconducting magnets the current distribution in the cable during ramping depends mainly on the electromagnetic properties of the system. A detailed analysis of principle causes for RRL phenomena was performed with a model for one half of the POLO coil considering the complete inductance matrix of the cable and the fact that all turns are mutually coupled. The main results of these calculations are that unequal contact resistances can not be responsible for RRL phenomena in coils with parameters comparable to those of the POLO coil and that already minor geometrical disturbances in the cable structure can lead to major and lasting imbalances in the current distribution of cables with insulated and non-insulated strands. During the POLO experiment the half-coil model was employed to get a better understanding of the measured compensated subcable voltages during quench. The good agreement of the calculated and measured results demonstrates the validity of the model for RRL analyses. (orig.)

  1. Electromagnetic Transients in Power Cables

    DEFF Research Database (Denmark)

    Silva, Filipe Faria Da; Bak, Claus Leth

    . The chapter ends by proposing a systematic method that can be used when doing the insulation co-ordination study for a line, as well as the modelling requirements, both modelling depth and modelling detail of the equipment, for the study of the different types of transients followed by a step-by-step generic...... typically used for the screens of cables (both-ends bonding and cross-boding) and also presents methods that can be used to estimate the maximum current of a cable for different types of soils, i.e. thermal calculations. The end of the chapter introduces the shunt reactor, which is an important element...... detail of the equipment, for the study of the different types of transients followed by a step-by-step generic example....

  2. Condition based maintenance of a 20 kV-PE/XLPE-insulated cable network using the IRC-Analysis; Zustandsorientierte Instandhaltung eines polymerisolierten 20-kV-Kabelnetzes mit der IRC-Analyse. Moderne Diagnostik reduziert Stoerungsrate

    Energy Technology Data Exchange (ETDEWEB)

    Hoff, G.; Kranz, H.G. [BUGH Wuppertal (Germany). Labs. fuer Hochspannungstechnik; Beigert, M.; Petzold, F. [Seba Dynatronic Mess- und Ortungstechnik GmbH, Baunach (Germany); Kneissl, C. [Bereich Konzeption und Messtechnik, Lech Elektrizitaetswerke AG, Augsburg (Germany)

    2001-10-22

    For a preventive maintenance of a polymer insulated cable network a destruction free estimation of the status of the buried PE/XLPE-cables is needed. This contribution presents a condition based maintenance concept which is based on the IRC-Analysis. With this concept a major German utility was able to reduce the amount of failures in a part of the 20kV-cable network. The general tendency of increasing faults was broken. (orig.) [German] Die praeventive Instandhaltung in polymerisolierten Kabelnetzen setzt eine zerstoerungsfreie Zustandbestimmung von gelegten PE/VPE-isolierten Kabeln voraus. Die-Verfasser beschreiben ein zustandsorientiertes Wartungskonzept auf Basis der IRC-Analyse, mit dem es gelungen ist, in einem Teil des 20-kV-Kabelnetzes eines Energieversorgers die in der Vergangenheit stetig steigende Stoerungsrate drastisch zu reduzieren. (orig.)

  3. Converters and electric machines. Solid insulating materials. Electrical characteristics; Convertisseurs et machines electriques. Materiaux isolants solides. Caracteristiques electriques

    Energy Technology Data Exchange (ETDEWEB)

    Anton, A. [Institut National Superieur de Chimie Industrielle, 76 - Rouen (France)

    2003-08-01

    The aim of this article is to allow a preselection of a solid insulating material using the most common electrical characteristics: tangent of the loss angle, relative permittivity, dielectric rigidity, superficial resistivity, transverse resistivity, resistance to high voltage creeping spark currents, index of creeping resistance. The characteristics of the main solid insulating materials are presented in tables for: thermoplastics, thermosetting materials, natural insulating materials, mineral insulating materials, rubber and synthetic elastomers, stratified insulating materials, thermoplastic films, composite synthetic papers. A comparison is made between the different materials using the three properties: tangent of the loss angle, relative permittivity and resistance to HV spark creeping currents. (J.S.)

  4. Qualification of cables to IEEE standards 323-1974 and 383-1974

    International Nuclear Information System (INIS)

    Hosticka, C.; Kingsbury, E.R.; Bruhin, A.C.

    1980-01-01

    Wire and Cable manufacturers generally qualify products for class IE application by envelope type testing to user specifications and environmental conditions recommended by IEEE Standards 323-1974 and 383-1974. The General Electric Wire and Cable Business Department recently completed two such qualification programs. Cable constructions tested were 600V control cables and 600 V, 2kV, and 15kV power cables insulated with flame resistant mineral filled crosslinked polyethylene. The 15kV samples included taped field splices. In the second test program, the steam pressure-temperature profile included a simulated main steam line break. Test specimens were wrapped on grounded mandrels and were electrically loaded throughout the simulated LOCA tests. After completion of environmental testing, samples were subjected to the IEEE 383 simulated post-LOCA test. 6 refs

  5. Qualification of cables to IEEE standards 323-1974 and 383-1974

    International Nuclear Information System (INIS)

    Hosticka, C.; Kingsbury, E.R.; Bruhin, A.C.

    1980-01-01

    Wire and Cable manufacturers generally qualify products for class IE application by envelope type testing to user specifications and environmental conditions recommended by IEEE Standards 323-1974 and 383-1974. The General Electric Wire and Cable Business Department recently completed two such qualification programs. Cable constructions tested were 600V control cables and 600 V, 2KV, and 15KV power cables insulated with flame resistant mineral filled crosslinked polyethylene. The 15KV samples included taped field splices. In the second test program, the steam pressure-temperature profile included a simulated main steam line break. Test specimens were wrapped on grounded mandrels and were electrically loaded throughout the simulated LOCA tests. After completion of environmental testing, samples were subjected to the IEEE 383 simulated post-LOCA test. 6 refs

  6. A simple approach to measure the surface resistivity of insulating materials

    DEFF Research Database (Denmark)

    Yang, Zhenyu; Wang, Qian

    2011-01-01

    A simple approach for measuring high surface resistivity of insulating materials using standard laboratory equipments is proposed. The developed system consists of a DC power transformer, a concentric ring probe assembly and a digital multi-meter. The DC power transformer can provide either 500V ...... for different materials, source voltages, and serially connected resistors. The testing results showed that the developed system and methods can provide a reasonably accurate measurement of surface resistivity of insulating materials in a robust and economic manner.......A simple approach for measuring high surface resistivity of insulating materials using standard laboratory equipments is proposed. The developed system consists of a DC power transformer, a concentric ring probe assembly and a digital multi-meter. The DC power transformer can provide either 500V...... or 250V DC signal. The probe assembly is constructed according to Danish Standard (DS/EN 1149-1:2006). The multi-meter (Agilent 3440 1A 6½) is used to measure the micro voltage over a known resistor which is serially connected with electrodes in the probe assembly. In order to obtain reliable...

  7. Test results for cables used in nuclear power plants by a new environmental testing method

    International Nuclear Information System (INIS)

    Handa, Katsue; Fujimura, Shun-ichi; Hayashi, Toshiyasu; Takano, Keiji; Oya, Shingo

    1982-01-01

    In the nuclear power plants using PWRs or BWRs in Japan, environmental tests are provided, in which simulated LOCA conditions are considered so as to conform with Japanese conditions, and many cables which passed these tests are presently employed. Lately, the new environmental testing, in which a credible accident called MSLB (main steam line breakage) is taken into account, is investigated in PWR nuclear power plants, besides LOCA. This paper reports on the results of evaluating some PWR cables for this new environmental testing conditions. The several cables tested were selected out of PH cables (fire-retardant, ethylene propylene rubber insulated, chlorosulfonated polyethylene sheathed cables) as the cables for safety protecting circuits and to be used in containment vessels where the cables are to be exposed to severe environmental test conditions of 2 x 10 8 Rad γ-irradiation and simulated LOCA. All these cables have been accepted after the vertical tray burning test provided in the IEEE Standard 383. The new testing was carried out by sequentially applying thermal deterioration, γ-irradiation, and the exposure to steam (twice 300 s exposures to 190 deg C superheated steam). After completing each step, tensile strength, elongation, insulation resistance and breakdown voltage were measured, respectively. Every cable tested showed satisfactory breakdown voltage after the exposure to steam, thus it was decided to be acceptable. In future, it is required to investigate the influence of the rate of temperature rise on the cable to be tested in MSLB simulation. (Wakatsuki, Y.)

  8. Topological insulator materials and nanostructures for future electronics, spintronics and energy conversion

    International Nuclear Information System (INIS)

    Kantser, Valeriu

    2011-01-01

    Two fundamental electrons attributes in materials and nanostructures - charge and spin - determine their electronic properties. The processing of information in conventional electronic devices is based only on the charge of the electrons. Spin electronics, or spintronics, uses the spin of electrons, as well as their charge, to process information. Metals, semiconductors and insulators are the basic materials that constitute the components of electronic devices, and these have been transforming all aspects of society for over a century. In contrast, magnetic metals, half-metals, magnetic semiconductors, dilute magnetic semiconductors and magnetic insulators are the materials that will form the basis for spintronic devices. Materials with topological band structure attributes and having a zero-energy band gap surface states are a special class of these materials that exhibit some fascinating and superior electronic properties compared to conventional materials allowing to combine both charge and spin functionalities. This article reviews a range of topological insulator materials and nanostructures with tunable surface states, focusing on nanolayered and nanowire like structures. These materials and nanostructures all have intriguing physical properties and numerous potential practical applications in spintronics, electronics, optics and sensors.

  9. Acoustic parameters of sound insulating materials investigation in small reverberation rooms on rubber plates

    Directory of Open Access Journals (Sweden)

    О.О. Козлітін

    2005-01-01

    Full Text Available  The new method of sound insulating materials acoustic characteristics investigation in small reverberation rooms was elaborated. The research of sound insulating materials on rubber plates was done. The analysis of obtained results of acoustic parameters of materials being a part of the composite real structures of airplane was carried out.

  10. Composite carbon fiber cables; Des cables composites en fibres de carbone

    Energy Technology Data Exchange (ETDEWEB)

    Anon.

    2002-10-01

    In order to fulfill the requirements of offshore engineering, Freyssinet, a daughter company of the European Vinci group, has developed a series of high-performance carbon fiber cables. These composite materials have an excellent fatigue behaviour in a huge range of constraints. Moreover, their low weight allows the implementation of very long lengths of cables in marine environment with no loss in capacity. The specific weight of the current part of the cable is reduced by a factor of 4 with respect to an equivalent capacity armature made of steel. These materials were presented in June 2002 at the ultra deep engineering and technologies (UDET) exhibition of Brest (France). (J.S.)

  11. Absorbed Dose Distributions in Small Copper Wire Insulation due to Multiple-Sided Irradiations by 0.4 MeV Electrons

    DEFF Research Database (Denmark)

    Miller, Arne; McLaughlin, W. L.; Pedersen, Walther Batsberg

    1979-01-01

    When scanned electron beams are used to crosslink polymeric insulation of wire and cable, an important goal is to achieve optimum uniformity of absorbed dose distributions. Accurate measurements of dose distributions in a plastic dosimeter simulating a typical insulating material (polyethylene......) surrounding a copper wire core show that equal irradiations from as few as four sides give approximately isotropy and satisfactorily uniform energy depositions around the wire circumference. Electron beams of 0.4 MeV maximum energy were used to irradiate wires having a copper core of 1.0 mm dia....... and insulation thicknesses between 0.4 and 0.8 mm. The plastic dosimeter simulating polyethylene insulations was a thin radiochromic polyvinyl butyral film wrapped several times around the copper wire, such that when unwrapped and analyzed optically on a scanning microspectrophotometer, high-resolution radial...

  12. OTEC riser cable model and prototype testing

    Science.gov (United States)

    Kurt, J. P.; Schultz, J. A.; Roblee, L. H. S.

    1981-12-01

    Two different OTEC riser cables have been developed to span the distance between a floating OTEC power plant and the ocean floor. The major design concerns for a riser cable in the dynamic OTEC environment are fatigue, corrosion, and electrical/mechanical aging of the cable components. The basic properties of the cable materials were studied through tests on model cables and on samples of cable materials. Full-scale prototype cables were manufactured and were tested to measure their electrical and mechanical properties and performance. The full-scale testing was culminated by the electrical/mechanical fatigue test, which exposes full-scale cables to simultaneous tension, bending and electrical loads, all in a natural seawater environment.

  13. Calculation and measurement of space charge in MV-size xxtruded cables systems under load conditions

    NARCIS (Netherlands)

    Morshuis, P.H.F.; Bodega, R.; Fabiani, D.; Montanari, G.C.; Dissado, L.A.; Smit, J.J.

    2007-01-01

    A load current in dc high voltage cables results in a temperature drop across the insulation and hence a radial distribution of the insulation conductivity is found. Direct consequence is an accumulation of space charge in the bulk of the nsulation, that may significantly affect its reliability.

  14. SUPER-CAPACITOR APPLICATION IN ELECTRICAL POWER CABLE TESTING FACILITIES IN THERMAL ENDURANCE AND MECHANICAL BRACING TESTS

    Directory of Open Access Journals (Sweden)

    I. V. Oleksyuk

    2015-01-01

    Full Text Available The current-carrying cores of the electrical power cables should be resistant to effects of short-circuit currents whose values depend on the material of the core, its cross-sectional area, cable insulation properties, environment temperature, and the duration of the short-circuit current flow (1 and 3–4 sec. when tested for thermal endurance and mechanical bracing. The facilities for testing the 10 kV aluminum core cables with short-circuit current shall provide mechanical-bracing current 56,82 kA and thermal endurance current 11,16 kA. Although capacitors provide such values of the testing currents to the best advantage, utilizing conventional capacitor-units will involve large expenditures for erecting and  running a separate building. It is expedient to apply super-capacitors qua the electric power supply for testing facilities, as they are capacitors with double-electrical layer and involve the current values of tens of kilo-amperes.The insulation voltage during short-circuit current testing being not-standardized, it is not banned to apply voltages less than 10 kV when performing short-circuit thermal endurance and mechanical bracing tests for electrical power cables of 10 kV. The super-capacitor voltage variation-in-time graph consists of two regions: capacitive and resistive. The capacitive part corresponds to the voltage change consequent on the energy change in the super-capacitors. The resistive part shows the voltage variation due to the active resistance presence in the super-capacitor.The author offers the algorithm determining the number of super capacitors requisite for testing 10 kV-electrical power cables with short-circuit currents for thermal endurance and mechanical bracing. The paper shows that installation of super-capacitors in the facilities testing the cables with short-circuit currents reduces the area needed for the super-capacitors in comparison with conventional capacitors more than by one order of magnitude.

  15. State of the art on historic building insulation materials and retrofit strategies

    DEFF Research Database (Denmark)

    Blumberga, Andra; Kass, Kristaps; Kamendere, Edite

    2016-01-01

    This report provides an analysis and evaluation of a state-of-the-art of internal insulation materials and methods for application in historic buildings, and review on methods, tools and guidelines used as decision making tools for implementation of internal insulation in historic buildings. Hist...

  16. The degradation diagnosis of low voltage cables used at nuclear power plants

    International Nuclear Information System (INIS)

    Yamamoto, Toshio; Ashida, Tetsuya; Ikeda, Takeshi; Yasuhara, Takeshi; Takechi, Kei; Araki, Shogo

    2001-01-01

    Low voltage cables which have been used for the supply of electric power and the propagation of control signals in nuclear power plants must be sound for safe and stable operation. The long use of nuclear power plants has been reviewed, and the degradation diagnosis to estimate the soundness of low voltage cables has been emphasized. Mitsubishi Cable Industries has established a degradation diagnosis method of cables which convert the velocity of ultrasonic wave in the surface layer of the cable insulation or jacket into breaking elongation, and has developed a degradation diagnosis equipment of low voltage cables used at nuclear power plants in cooperation with Mitsubishi Heavy Industries. This equipment can be moved by an ultrasonic probe by sequential control and measure the ultrasonic velocity automatically. It is capable of a fast an sensitive diagnosis of the cables. We report the outline of this degradation diagnosis equipment and an example of the adaptability estimation at an actual nuclear power plant. (author)

  17. Towards a Spiderman suit: large invisible cables and self-cleaning releasable superadhesive materials

    International Nuclear Information System (INIS)

    Pugno, Nicola M

    2007-01-01

    Spiders can produce cobwebs with high strength to density ratio and surprisingly display self-cleaning, strong and releasable adhesion (like geckos). Nanointerlocking, capillary and van der Waals forces, all potential adhesive mechanisms, are thus discussed, demonstrating the key role played by hierarchy in the design of superhydrophobic, i.e. self-cleaning (dry or wet and enhanced by activating Fakir drops as in lotus leaves) and superadhesive materials. The reversibility of the strong attachment is quantified thanks to an improved nonlinear peeling model including friction, for which the solution in closed form is provided. Thus, mimicking nature, thanks to carbon-nanotube-based technology, we suggest the feasibility of large invisible cables, as well as of self-cleaning, superadhesive and releasable hierarchical smart materials. We found that a man can theoretically be supported by a transparent cable with cross-section of 1 cm 2 and feasibly, with spider material gloves and boots, could remain attached even to a ceiling: a preliminary step towards a Spiderman suit

  18. Towards a Spiderman suit: large invisible cables and self-cleaning releasable superadhesive materials

    Science.gov (United States)

    Pugno, Nicola M.

    2007-10-01

    Spiders can produce cobwebs with high strength to density ratio and surprisingly display self-cleaning, strong and releasable adhesion (like geckos). Nanointerlocking, capillary and van der Waals forces, all potential adhesive mechanisms, are thus discussed, demonstrating the key role played by hierarchy in the design of superhydrophobic, i.e. self-cleaning (dry or wet and enhanced by activating Fakir drops as in lotus leaves) and superadhesive materials. The reversibility of the strong attachment is quantified thanks to an improved nonlinear peeling model including friction, for which the solution in closed form is provided. Thus, mimicking nature, thanks to carbon-nanotube-based technology, we suggest the feasibility of large invisible cables, as well as of self-cleaning, superadhesive and releasable hierarchical smart materials. We found that a man can theoretically be supported by a transparent cable with cross-section of 1 cm2 and feasibly, with spider material gloves and boots, could remain attached even to a ceiling: a preliminary step towards a Spiderman suit.

  19. Towards a Spiderman suit: large invisible cables and self-cleaning releasable superadhesive materials

    Energy Technology Data Exchange (ETDEWEB)

    Pugno, Nicola M [Department of Structural Engineering, Politecnico di Torino, Corso Duca degli Abruzzi 24, 10129 Turin (Italy)

    2007-10-03

    Spiders can produce cobwebs with high strength to density ratio and surprisingly display self-cleaning, strong and releasable adhesion (like geckos). Nanointerlocking, capillary and van der Waals forces, all potential adhesive mechanisms, are thus discussed, demonstrating the key role played by hierarchy in the design of superhydrophobic, i.e. self-cleaning (dry or wet and enhanced by activating Fakir drops as in lotus leaves) and superadhesive materials. The reversibility of the strong attachment is quantified thanks to an improved nonlinear peeling model including friction, for which the solution in closed form is provided. Thus, mimicking nature, thanks to carbon-nanotube-based technology, we suggest the feasibility of large invisible cables, as well as of self-cleaning, superadhesive and releasable hierarchical smart materials. We found that a man can theoretically be supported by a transparent cable with cross-section of 1 cm{sup 2} and feasibly, with spider material gloves and boots, could remain attached even to a ceiling: a preliminary step towards a Spiderman suit.

  20. Complex evaluation of properties for some thermal insulating materials of NPP

    International Nuclear Information System (INIS)

    Yurchenko, V.G.; Nazarova, G.A.; Yakunichev, V.N.; Potulov, V.V.; Kazakova, K.A.

    1991-01-01

    The effects of the main operational factors (temperature, ionizing radiation, increased humidity) on some most widely applied fibrous materials are investigated. The samples were irradiated by 60 Co gamma photons at the PKhM-gamma-20 device in air at temperature of 40±1 deg C in order to analyze the radiation resistance of thermal insulating materials. The analysis and generalization of the results of laboratory tests give an opportunity to make the following conclusions. The thermal insulation articles and constructions made of superfine basalt fiber may be used in the zones of rigorous regime. The superfine glass fibers (GF) are recommended to be used for equipment and pipeline shielding in the zones of rigorous control only as a part of multilayer insulation as the second or next layers and only in places where leaks are impossible

  1. Sound absorption of low-temperature reusable surface insulation candidate materials

    Science.gov (United States)

    Johnston, J. D.

    1974-01-01

    Sound absorption data from tests of four candidate low-temperature reusable surface insulation materials are presented. Limitations on the use of the data are discussed, conclusions concerning the effective absorption of the materials are drawn, and the relative significance to Vibration and Acoustic Test Facility test planning of the absorption of each material is assessed.

  2. Fatigue effects in insulation materials for fusion magnets

    International Nuclear Information System (INIS)

    Rosenkranz, P.

    2000-12-01

    The mechanical properties of insulation materials for the superconducting magnets of ITER (International Thermonuclear Experimental Reactor) and future fusion plants, i.e. woven fiber reinforced composites, have been identified as an area of concern for the long-term operation of such magnets. The magnets will be subjected to fast neutron and γ-radiation over their lifetime, which influence the mechanical properties of the insulation materials. The ultimate tensile strength and, above all, the interlaminar shear strength and their performance under dynamic load, corresponding to the pulsed operation of a TOKAMAK-confinement system, are sensitive indicators of material failure in fiber-reinforced laminates especially at cryogenic temperatures. To simulate these conditions, low frequency fatigue measurements at 10 Hz were made at 77 K up to one million cycles. Tension-tension fatigue tests were performed according to ASTM D3479. However, due to the space limitations in all irradiation facilities, the tests have to be done on samples, which are considerably smaller than those required for standard test conditions. The influence of the specimen geometry on the ultimate tensile strength under static and dynamic load conditions was, therefore, investigated on fiber-reinforced plastics. They did not show any systematic trends as long as the sample thickness does not exceed the thickness recommended in ASTM D3479. The double lap shear test method was chosen for the shear experiments because of the symmetry of the specimen geometry under tensile load and the suitability for fatigue tests. Like almost every existing test procedure for the interlaminar shear strength, this test method does not provide for a completely uniform interlaminar shear stress distribution over a sizable region in the test section of the specimen. A scaling program combined with FE-simulations was, therefore, initiated to assess the influence of the length of the test section and of the sample

  3. Thermal insulating panel

    Energy Technology Data Exchange (ETDEWEB)

    Hughes, J.T.

    1985-09-11

    A panel of thermal insulation material has at least one main portion which comprises a dry particulate insulation material compressed within a porous envelope so that it is rigid or substantially rigid and at least one auxiliary portion which is secured to and extends along at least one of the edges of the main portions. The auxiliary portions comprise a substantially uncompressed dry particulate insulation material contained within an envelope. The insulation material of the auxiliary portion may be the same as or may be different from the insulation material of the main portion. The envelope of the auxiliary portion may be made of a porous or a non-porous material. (author).

  4. Investigation of Insulation Materials for Future Radioisotope Power Systems (RPS)

    Science.gov (United States)

    Cornell, Peggy A.; Hurwitz, Frances I.; Ellis, David L.; Schmitz, Paul C.

    2013-01-01

    NASA's Radioisotope Power System (RPS) Technology Advancement Project is developing next generation high temperature insulation materials that directly benefit thermal management and improve performance of RPS for future science missions. Preliminary studies on the use of multilayer insulation (MLI) for Stirling convertors used on the Advanced Stirling Radioisotope Generator (ASRG) have shown the potential benefits of MLI for space vacuum applications in reducing generator size and increasing specific power (W/kg) as compared to the baseline Microtherm HT (Microtherm, Inc.) insulation. Further studies are currently being conducted at NASA Glenn Research Center (GRC) on candidate MLI foils and aerogel composite spacers. This paper presents the method of testing of foils and spacers and experimental results to date.

  5. Influence of Wind Speed on Heat Flow through Polypropylene Insulating Material

    Institute of Scientific and Technical Information of China (English)

    SUN Yu-chai; CHENG Zhong-hao; FENG Xun-wei

    2006-01-01

    The heat transfer properties of polypropylene insulation at different ambient temperature against wind were analysed.A theoretical model of the combined conductive, convective and radiative heat flow through fibrous insulating material was presented. Detail study was carried out by using the finite element method. The theoretical results are in accordance to the experimental results which were accomplished in an artificial climate chamber.

  6. Report on full-scale horizontal cable tray fire tests, FY 1988

    International Nuclear Information System (INIS)

    Riches, W.M.

    1988-09-01

    In recent years, there has been much discussion throughout industry and various governmental and fire protection agencies relative to the flammability and fire propagation characteristics of electrical cables in open cable trays. It has been acknowledged that under actual fire conditions, in the presence of other combustibles, electrical cable insulation can contribute to combustible fire loading and toxicity of smoke generation. Considerable research has been conducted on vertical cable tray fire propagation, mostly under small scale laboratory conditions. In July 1987, the Fermi National Accelerator Laboratory initiated a program of full scale, horizontal cable tray fire tests, in the absence of other building combustible loading, to determine the flammability and rate of horizontal fire propagation in cable tray configurations and cable mixes typical of those existing in underground tunnel enclosures and support buildings at the Laboratory. The series of tests addressed the effects of ventilation rates and cable tray fill, fire fighting techniques, and effectiveness and value of automatic sprinklers, smoke detection and cable coating fire barriers in detecting, controlling or extinguishing a cable tray fire. This report includes a description of the series of fire tests completed in June 1988, as well as conclusions reached from the test results

  7. Analysis of effect of cable degradation on SPND IR calculation

    International Nuclear Information System (INIS)

    Tamboli, P.K.; Sharma, A.; Prasad, A.D.; Singh, Nita; Antony, J.; Kelkar, M.G.; Kaurav, Reetesh; Pramanik, M.

    2013-01-01

    Neutron flux is the most vital parameter in the nuclear reactor safety against Neutronic over power. The modern days Indian PHWRs with large core size are loosely coupled reactors and hence In-core Self Power Neutron Detectors (SPNDs) are most suitable for monitoring local neutron power for generating Regional Overpower Trip. However the SPNDs and its Mineral Insulation Cable are prone to IR loss due to use of ceramic insulation which are highly hygroscopic. The present paper covers the online analysis of IR f degraded cable as per the surveillance requirement of monitoring the IR to assess the healthiness of SPNDs which are part of SSC/SSE for Reactor Protection Systems. The paper also proposes an alternative method for monitoring IR for startup//low power range when SPND signals are yet to pick up and Reactor Control and Protection are based on out of core Ionization Chambers. (author)

  8. Neutron and gamma irradiation effects on organic insulating materials for fusion magnets

    International Nuclear Information System (INIS)

    Maurer, W.

    1985-10-01

    Available low-temperature neutron and gamma irradiation data for organic insulating materials are collected and compared with room temperature data. Only the most promising polymers in terms of mechanical strength for magnet insulation are taken into account. For characterization and comparison of different materials the 75% dose is used, i.e. the dose, where the mechanical strength is reduced by 25%, and 75% is retained. For room temperature special prepared polyimide and epoxy materials reinforced with glass fibre retained 75% of the mechanical strength up to a dose of 7x10 7 Gy. For 5 K irradiation the best epoxy material retained the 75% dose up to 1x10 7 Gy, the best polyimide material up to 1x10 8 Gy. (orig.) [de

  9. Compilation of radiation damage test data part III: materials used around high-energy accelerators

    CERN Document Server

    Beynel, P; Schönbacher, H; CERN. Geneva

    1982-01-01

    For pt.II see CERN report 79-08 (1979). This handbook gives the results of radiation damage tests on various engineering materials and components intended for installation in radiation areas of the CERN high-energy particle accelerators. It complements two previous volumes covering organic cable-insulating materials and thermoplastic and thermosetting resins.

  10. Verification of the behavior of insulating materials under ionizing radiation

    International Nuclear Information System (INIS)

    Reis, Joao C. Marques dos; Rezende, Aurimar de P.; Menzel, Silvio C.

    2009-01-01

    To analyze the behavior of specifics electrical insulating materials and components under ionizing radiation, a test program was developed to verify the overall effects of general electrical equipment under high radiation fields conditions. The main objective is for maintenance purposes, in the substitution of electrical components installed in the reactor building of the Angra 1 nuclear power plant. Knowing the characteristics of electrical insulating materials available in the country and determining by tests their ability to withstand the ionizing radiation effects, is feasible to implement specific maintenance services of electrical equipment, maintaining the same level of quality and safety for the specified application. This procedure reduces the time and also costs of maintenance services, in comparison with materials acquired or services performed abroad. The isolating materials and components of electrical equipment should be specified, manufactured and qualified to withstand aggressive environmental conditions in the reactor building during the normal operation and postulated accident. Additional tests should be conducted to verify the conditions of the aged material by ionizing radiation. Examples of additional tests: dielectric strength, tensile strength and elongation and impact resistance. (author)

  11. Controlling the Optical and Magnetic Properties of Nanostructured Cuprous Oxide Synthesized from Waste Electric Cables

    Science.gov (United States)

    Abdelbasir, S. M.; El-Sheikh, S. M.; Rashad, M. M.; Rayan, D. A.

    2018-03-01

    Cuprous oxide Cu2O nanopowders were purposefully synthesised from waste electric cables (WECs) via a simple precipitation route at room temperature using lactose as a reducing agent. In this regard, dimethyl sulfoxide (DMSO) was first applied as an organic solvent for the dissolution of the cable insulating materials. Several parameters were investigated during dissolution of WECs such as dissolution temperature, time and solid/liquid ratio to determine the dissolution percentage of the insulating materials in DMSO. The morphology and the optical properties of the formed Cu2O particles were investigated using X-ray diffraction (XRD), field emission-scanning electron microscopy (FE-SEM), Fourier-transform infrared spectroscopy and UV-visible-near IR spectrophotometer. XRD data confirmed the presence of single crystalline phase of Cu2O nanoparticles. FE-SEM and TEM images revealed spherical, cubic and octahedral shapes with the various particle sizes ranged from 16 to 57 nm depending on the synthesis conditions. A possible mechanism explaining the Cu2O nanostructures formation was proposed. The band gap energies of the Cu2O nanostructures were estimated and the values were located between 1.5 and 2.08 eV. Photoluminescence spectroscopy analysis clearly showed a noticeably blue-shifted emission for the synthesized samples compared to spectrum of the bulk. Eventually, magnetic properties of the synthesized nanoparticles have been measured by vibrating sample magnetometer and the attained results implied that the synthesized particles are weakly ferromagnetic in nature at normal temperature.

  12. Investigation of electrophysical properties of electrical insulating materials under neutron irradiation

    International Nuclear Information System (INIS)

    Skornyakov, Yu.A.; Stepanov, A.N.; Lapenas, A.A.

    1978-01-01

    The possibilities of applicaiton of insulating materials on the basis of glass cloths in electric windings for operation under neutron radiation of thermonuclear devices are studied. Changes in the specimen resistance, tangent of the angle of dielectric losses, electric strength according to the value of neutron fluence are determined. The temperature regimes are also studied. The data indicate the irreversible changes in the composition and structure of the polymer material under irradiation. The LSMI 228L-80 glass cloth has the highest radiation resistance. The necessity of forced cooling of large-sized specimens under the neutron radiation the IRT-200 reactor is established. The presence of impurities leading to the long-term induced activity of the insulating materials ( 59 Fe, 60 Co) is determined

  13. Workshop on technical assessment of industrial thermal insulation materials: summary

    International Nuclear Information System (INIS)

    Peterson, S.

    1976-07-01

    Over 80 participants representing 50 organizations met to discuss the report, Industrial Thermal Insulation--An Assessment, ORNL/TM-5283. Presentations on the performance of available materials, economic considerations, and measurement problems were followed by discussion. A final wrap-up session concluded that the report was valuable in pointing the direction for needed effort in the area, confirmed the indicated actions needed to further industrial application of insulation, and called for future meetings to continue the dialogue between the various facets of the industry

  14. Ground Return Current Behaviour in High Voltage Alternating Current Insulated Cables

    Directory of Open Access Journals (Sweden)

    Roberto Benato

    2014-12-01

    Full Text Available The knowledge of ground return current in fault occurrence plays a key role in the dimensioning of the earthing grid of substations and of cable sealing end compounds, in the computation of rise of earth potential at substation sites and in electromagnetic interference (EMI on neighbouring parallel metallic conductors (pipes, handrails, etc.. Moreover, the ground return current evaluation is also important in steady-state regime since this stray current can be responsible for EMI and also for alternating current (AC corrosion. In fault situations and under some assumptions, the ground return current value at a substation site can be computed by means of k-factors. The paper shows that these simplified and approximated approaches have a lot of limitations and only multiconductor analysis can show the ground return current behaviour along the cable (not only the two end values both in steady-state regime and in short circuit occurrence (e.g., phase-to-ground and phase-to-phase-to-ground. Multiconductor cell analysis (MCA considers the cable system in its real asymmetry without simplified and approximated hypotheses. The sensitivity of ground return current on circuit parameters (cross-bonding box resistances, substation earthing resistances, soil resistivity is presented in the paper.

  15. High Temperature Electrical Insulation Materials for Space Applications, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — NASA's future space science missions cannot be realized without the state of the art high temperature insulation materials of which higher working temperature, high...

  16. Behaviour of organic materials in radiation environment

    International Nuclear Information System (INIS)

    Tavlet, M.; Ilie, S.

    1999-01-01

    An extensive radiation damage test program has been carried out in CERN for decades and many results have yet been published. Over the years, EPR/EPDM-based rubbers and polyolefin-based compounds used for cable insulation have been tested. Polyolefin-based compounds usually present an important dose-rate effect. This is related to the presence of oxygen, it may be combined with a temperature effect. On the other hand, it appears from many results that the degradation of cable insulations does not depend on the radiation type. Tests of insulating and structural materials after irradiation at cryogenic temperature have shown that there is no significant influence of the irradiation temperature on the radiation degradation of thermo-sets and composites, while the degradation of plastic films is even less severe as they are protected against oxidation. Some experiments about the synergy between irradiation and mechanical stress have shown that rubbers and composites under stress are more sensitive to radiation and degrade faster. Very strong synergetic effects between radiation and other parameters are observed in organic optical materials such as scintillators and optical fibres. For fluorocarbon cooling fluids, a special care must be paid to alkanes and hydro-fluoro-alkanes, which are usually present as impurities, and of which the C-H bonds content opens the way to the reactive hydrofluoric acid evolution during the radiolytic process

  17. Innovating Technological Process for Expanding the Service Life of Underground Power Cables

    Directory of Open Access Journals (Sweden)

    Tabacaru V.

    2016-08-01

    Full Text Available As a public power distribution operator on low voltage (023/0.4 kV, medium voltage (6 and 20 kV, and high voltage (110 kV in the territory of Galati County, SDEE Galati serves approximately 240,000 consumers (captive and eligible, domestic and non-domestic For this purpose, in the field of medium voltage underground distribution lines, SDEE Galati manages and operates a volume of approx. 500 km UDL/6kV circuit and approximately 630 km UDL/20 kV circuit. Many of these cables which are still in operation, were manufactured with materials and on the technological level of the ’60s,’70s and ‘80s decades and have reached the end of their service life. Evidence does and incident statistics from these networks in which, every year, one of the "tips" is the medium voltage cables damaged "technical wear" normal operating conditions. The current paper will present the main features of an innovating technological process called SPR (Sustained Pressure Rejuvenation, designed for on-site refurbishing of underground power cable insulation medium and high voltage. The process offers a viable alternative that has proven, over the 25 years of application initially on the American content and now on the worldwide, substantially more cost effective than replacing cables. The paper does not propose detailed presentation of the technological process, but to inform the family of energetics NPS about the existence and the benefits of applying this new technological process to the old cable medium and high voltage.

  18. Design of load-to-failure tests of high-voltage insulation breaks for ITER's cryogenic network

    CERN Document Server

    Langeslag, S A E; Aviles Santillana, I; Sgobba, S; Foussat, A

    2015-01-01

    The development of new generation superconducting magnets for fusion research, such as the ITER experiment, is largely based on coils wound with so-called cable-in-conduit conductors. The concept of the cable-in-conduit conductor is based on a direct cooling principle, by supercritical helium, flowing through the central region of the conductor, in close contact with the superconducting strands. Consequently, a direct connection exists between the electrically grounded helium coolant supply line and the highly energised magnet windings. Various insulated regions, constructed out of high-voltage insulation breaks, are put in place to isolate sectors with different electrical potential. In addition to high voltages and significant internal helium pressure, the insulation breaks will experience various mechanical forces resulting from differential thermal contraction phenomena and electro-magnetic loads. Special test equipment was designed, prepared and employed to assess the mechanical reliability of the insul...

  19. Investigation of deterioration mechanism of electrical ceramic insulating materials under high temperature

    International Nuclear Information System (INIS)

    Mizutani, Yoshinobu; Ito, Tetsuo; Okamoto, Tatsuki; Kumazawa, Ryoji; Aizawa, Rie; Moriyama, Hideshige

    2000-01-01

    It is thought that ceramic insulator can be applied to electric power equipments that are under high temperature not to be able use organic materials. Our research has suggested components of mica-alumina combined insulation. As the results of and carried out temperature accelerating test, combined insulation life is expected long term over 40 years at over 500-Celsius degrees. However to construct high reliable insulating system, it is clarified deterioration mechanism on combined insulation and evaluates life of that. Therefore we carried out metal behavior test and voltage aging test using mica-sheet and alumina-cloth that are components of combined insulation under high temperature in nitrogen gas atmosphere. It is cleared two metal behavior mechanisms: One is that the opening of insulator are filled up with copper that is oxidized, the other is the metal diffuses in alumina-cloth through surface. And distance of metal behavior is able to be estimated at modulate temperature and in modulate time. It is also cleared that alumina-cloth is deteriorated by metal behavior into alumina-cloth. These results indicate that combined insulation is deteriorated from electrode side by metal behavior and is finally broken down through alumina-cloth. (author)

  20. Teaching Acoustic Properties of Materials in Secondary School: Testing Sound Insulators

    Science.gov (United States)

    Hernandez, M. I.; Couso, D.; Pinto, R.

    2011-01-01

    Teaching the acoustic properties of materials is a good way to teach physics concepts, extending them into the technological arena related to materials science. This article describes an innovative approach for teaching sound and acoustics in combination with sound insulating materials in secondary school (15-16-year-old students). Concerning the…

  1. Cavitation as a Precursor to Breakdown of Mass-Impregnated HVDC Cables

    Energy Technology Data Exchange (ETDEWEB)

    Evenset, Gunnar

    1999-09-01

    Thermal cycling has proven to be a critical test for mass-impregnated HVDC cables. The dielectric strength of the insulation is significantly reduced during the first part of the cooling. This decrease of the dielectric strength limits the development of mass-impregnated cables for higher operating voltages and higher power transfer capacities. The decrease of the dielectric strength during cooling has been assumed to be caused by formation of cavities in the mass because the thermal contraction of the mass is larger than that of the paper. Cavities have previously been observed in thermally cycled cables, but their actual formation and growth have not been studied. The fact that breakdown usually occurs a few hours into the cooling period indicates that the dynamics of the growth is important. This work studies the dynamic phenomena occurring in mass-impregnated cables during thermal cycling. In experiments on a system of mass and insulating paper, cavities were observed near the paper surface, probably caused by heterogeneous nucleation. Knowing the tensile stress at cavity formation is important because it controls the size of the cavities and the distance between independently formed cavities in a cable insulation. A test cell was designed to investigate cavitation in models of lapped insulation. The formation, growth and collapse of the cavities could be visually observed while the insulation was electrically stressed and partial discharges were measured. The first cavity generally formed in one of the butt gaps and grew both along the butt gap and into the mass layers between the papers towards adjacent butt gaps. When the cavity between the papers grew into an adjacent butt gap, the gas/vapour filled channel connecting the butt gaps was closed. In this way, one cavity grew into several butt gaps. The extent of cavities between the papers was observed to depend on the interfacial pressure. Considerable less tension is required to suck the menisci of a cavity

  2. Self-Healing Wire Insulation

    Science.gov (United States)

    Parrish, Clyde F. (Inventor)

    2012-01-01

    A self-healing system for an insulation material initiates a self-repair process by rupturing a plurality of microcapsules disposed on the insulation material. When the plurality of microcapsules are ruptured, reactants within the plurality of microcapsules react to form a replacement polymer in a break of the insulation material. This self-healing system has the ability to repair multiple breaks in a length of insulation material without exhausting the repair properties of the material.

  3. FMIT test cell diagnostics: a unique materials challenge

    International Nuclear Information System (INIS)

    Cannon, C.P.; Fuller, J.L.

    1981-08-01

    Basic materials problems are discussed in instrumenting the FMIT test cell, which are applicable to fusion devices in general. Recent data on ceramic-to-metal seals, mineral insulated instrument cables, thermocouples, and optical components are reviewed. The data makes it clear that it would be a mistake to assume that materials and instruments will behave in the FMIT test cell environment as they do in more familiar fission reactors and low power accelerators

  4. Superheated-steam test of ethylene propylene rubber cables using a simultaneous aging and accident environment

    International Nuclear Information System (INIS)

    Bennett, P.R.; St Clair, S.D.; Gilmore, T.W.

    1986-06-01

    The superheated-steam test exposed different ethylene propylene rubber (EPR) cables and insulation specimens to simultaneous aging and a 21-day simultaneous accident environment. In addition, some insulation specimens were exposed to five different aging conditions prior to the 21-day simultaneous accident simulation. The purpose of this superheated-steam test (a follow-on to the saturated-steam tests (NUREG/CR-3538)) was to: (1) examine electrical degradation of different configurations of EPR cables; (2) investigate differences between using superheated-steam or saturated-steam at the start of an accident simulation; (3) determine whether the aging technique used in the saturated-steam test induced artificial degradation; and (4) identify the constituents in EPR that affect moisture absorption

  5. Flammability of radiation cross-linked low density polyethylene as an insulating material for wire and cable

    International Nuclear Information System (INIS)

    Basfar, A.A.

    2002-01-01

    Various formulations of low-density polyethylene blended with ethylene vinyl acetate were prepared to improve the flame retardancy for wire and cable applications. The prepared formulations were cross-linked by γ-rays to 50, 100, 150 and 200 kGy in the presence of trimethylolpropane triacrylate (TMPTA). The effect of thermal aging on mechanical properties of these formulations were investigated. In addition, the influence of various combinations of aluminum trihydroxide and zinc borate as flame retardant fillers on the flammability was explored. Limiting oxygen index (LOI) and average extent of burning were used to characterize the flammability of investigated formulations. An improved flame retardancy of low density polyethylene was achieved by various combinations of flame ratardant fillers and cross-linking by gamma radiation

  6. Utilization of two-way multicore cables and comparison of various electrode configurations in electrical prospecting; Denki tansa ni okeru sohokogata tashin cable no riyo to kakushu dekyoku haichi no hikaku

    Energy Technology Data Exchange (ETDEWEB)

    Takakura, S [Geological Survey of Japan, Tsukuba (Japan); Matsushima, J [The University of Tokyo, Tokyo (Japan). Faculty of Engineering

    1996-10-01

    For more precise electrical prospecting, the new multicore cable was developed to allow high-density measurement by conventional equipment. Since conventional multicore cables are inferior in cost, length and weight, the new cable is composed of an n-conductor cable, two n-conductor male connectors and n lead wires. For connection of the multi-conductor cable and lead wires, cable sheath is peeled at n points at specific intervals. Sheath of the k-th conductor is peeled at k-th point from the terminal, and restored for insulation after connection of the conductor and lead wire. The male connectors are attached to the both ends of the multi-conductor cable. Since this two-way type cable can be used at every end, the measuring equipment can measure at one divisional point after another of a long measuring line while shifting the equipment from one point to another. All measurements are perfected only with two short cables. Resistivities were successfully measured along the long measuring line of 480m long with 97 electrodes arranged at intervals of 5m. Various electrode configurations were also compared. 1 ref., 4 figs., 2 tabs.

  7. Statistical analysis of aging trend of mechanical properties in ethylene propylene rubber-insulated safety-related cables sampled from containments (Denryoko Chuo Kenkyusho Hokoku, December 2013 issue)

    International Nuclear Information System (INIS)

    Fuse, Norikazu; Kanegami, Masaki; Misaka, Hideki; Homma, Hiroya; Okamoto, Tatsuki

    2013-01-01

    As for polymeric insulations used in nuclear power plant safety cables, it is known that the present prediction model sometimes estimates the service life conservatively. In order to sophisticate the model to reflect to the aging in containments, disconnections between the prediction and realities are needed to be clarified. In the present paper, statistical analysis has been carried out on various aging status of insulations removed from domestic containments. Aging in operational environment is found to be slower than the one expected from acceleration aging test results. Temperature dependence of estimated lifetime on Arrhenius plot also suggests that elementary chemical reaction dominant under the two aging conditions is different, which results in apparent difference in activation energies and pre-exponential factors. Following two kinds of issues are found necessary to be clarified for the model sophistication; temperature change in predominant degradation chemical processes, and the effect of low oxygen concentration environment in boiling water reactor type containment. (author)

  8. Moisture buffer capacity of different insulation materials

    DEFF Research Database (Denmark)

    Peuhkuri, Ruut Hannele; Rode, Carsten; Hansen, Kurt Kielsgaard

    2004-01-01

    . In the isothermal tests the material samples were exposed to the same change in the relative humidity of the ambient air on both sides, while the samples were exposed to variations in relative humidity only on the cold side in the non-isothermal tests. The results of these rather different measurement principles...... lead to more durable constructions. In this paper, a large range of very different thermal insulation materials have been tested in specially constructed laboratory facilities to determine their moisture buffer capacity. Both isothermal and nonisothermal experimental set-ups have been used...... are discussed, and different ways are presented how to determine the moisture buffer capacity of the materials using partly standard material parameters and partly parameters determined from the actual measurements. The results so far show that the determination of moisture buffer capacity is very sensitive...

  9. Thermal Conductance and High-Frequency Properties of Cryogenic Normal or Superconducting Semi-rigid Coaxial Cables in the Temperature Range of 1-8 K

    Science.gov (United States)

    Kushino, A.; Kasai, S.; Ukibe, M.; Ohkubo, M.

    2018-04-01

    In this study, the characteristics of thin semi-rigid cables composed of different conductors and with outer diameters ranging from 0.86 to 1.19 mm were investigated at low temperatures. The thermal conductance was measured between approximately 1 and 8 K, and the frequency dependence of the attenuation in the cables was obtained at 3 K. The electrical conductors used in the cables were alloys: beryllium copper, brass, stainless steel (SUS304), phosphor bronze, cupronickel (CuNi), and niobium-titanium (NbTi). The thermal conductance of a commercial miniature coaxial cable with braided wires forming the outer electrical conductor was also examined for reference. The measured thermal conductance was compared to published data and that generated from material libraries and databases. Among the measured cables using normal metals, the semi-rigid cable composed of SUS304 conductors and a polytetrafluoroethylene insulator showed the lowest thermal conductance. The transmission performance of the semi-rigid cables using SUS304 or CuNi was improved by plating the central conductors with a silver coating of approximately 3 μm thickness, and their thermal conductance with the plating increased by approximately one order of magnitude. The superconducting NbTi semi-rigid cable exhibited the lowest thermal conductance of all the cables considered in the present study along with very small attenuation up to above 5 GHz.

  10. Assessment of Cable Aging Equipment, Status of Acquired Materials, and Experimental Matrix at the Pacific Northwest National Laboratory

    Energy Technology Data Exchange (ETDEWEB)

    Fifield, Leonard S. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Westman, Matthew P. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Zwoster, Andy [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Schwenzer, Birgit [Pacific Northwest National Lab. (PNNL), Richland, WA (United States)

    2015-03-30

    The need for increased understanding of the aging and degradation behavior for polymer components of nuclear power plant electrical cables is described in this report. The highest priority materials for study and the resources available at PNNL for these studies are also described. The anticipated outcomes of the PNNL work described are : improved understanding of appropriate accelerated aging conditions, improved knowledge of correlation between observable aging indicators and cable condition in support of advanced non-destructive evaluation methods, and practical knowledge of condition-based cable lifetime prediction.

  11. Transport and screen blockage characteristics of reflective metallic insulation materials

    International Nuclear Information System (INIS)

    Brocard, D.N.

    1984-01-01

    In the event of a LOCA within a nuclear power plant, it is possible for insulation debris to be generated by the break jet. Such debris has the potential for PWR sump screen (or BWR RHR suction inlet) blockage and thus can affect the long-term recirculation capability. In addition to the variables of break jet location and orientation, the types and quantities of debris which could be generated are dependent on the insulation materials employed. This experimental investigation was limited to reflective metallic insulation and components thereof. The study was aimed at determining the flow velocities needed to transport the insulation debris to the sump screens and the resulting modes of screen blockage. The tests revealed that thin metallic foils (0.0025 in. and 0.004 in.) could transport at low flow velocities, 0.2 to 0.5 ft/sec. Thicker foils (0.008 in.) transported at higher velocities, 0.4 to 0.8 ft/sec, and as fabricated half cylinder insulation units required velocities in excess of 1.0 ft/sec for transport. The tests also provided information on screen blockage patterns that showed blockage could occur at the lower portion of the screen as foils readily flipped on the screen when reaching it

  12. Partial discharge testing of in-situ power cable accessories

    Energy Technology Data Exchange (ETDEWEB)

    Orban, H. E.

    2002-07-01

    An overview of commercially available diagnostic methods for in-situ power cable accessories is given and relevant field experiences with these diagnostics are described. The discussion includes both PILC and polymeric insulated cables. Two major types of degradation are most frequently involved in cable systems. One is an overall condition caused by chemical aging and /or water treeing. Diagnostics for this type of aging include dissipation factor (loss angle), harmonic analysis, return voltage, isothermal relaxation current, dielectric response, or dc leakage current. The second type of degradation is discrete or incremental; condition assessment utilizes dissipation factor measurements or partial discharge (PD) level measurements. The focus in this paper is on PD diagnostics, especially off-line methods such as the 60 Hz test, the combined AC and VLF diagnostic, and the oscillating wave test system test. Among on-line diagnostics, ultrasonic detection of partial discharge and measurement of partial discharge by installing direct, capacitive or inductive couplers near cable accessories, are described. Overall, partial discharge detection and location in cable accessories is considered inadequate, since interpretation of results is difficult due to the number of variables involved. 28 refs., 1 tab.

  13. Waste management, energy generation, material recycling

    Energy Technology Data Exchange (ETDEWEB)

    1982-01-01

    The concept of process pyrolysis according to the system of low-temperature pyrolysis (up to 450 Cel) for the purpose of waste processing is described. This system not only uses the material value (raw materials) but also the processing value (energetic utilization of organic components). Three product groups are mentioned where process pyrolysis can be applied: 1. rubber-metall connecting, coated and non-coated components, 2. Compound materials like pc boards, used electronic devices, films, used cables and batteries, 3. organic waste and residues like foils, insulating material, lubricating, oil and grease, flooring. Importance of waste management is emphasized, economic aspects are illustrated.

  14. Radiation modification of materials

    International Nuclear Information System (INIS)

    Pikaev, A.K.

    1987-01-01

    Industrial and radiation chemical processes of material modification based on cross-linking of polymers as a result of radiation are considered. Among them are production of cables and rods with irradiated modified insulation, production of hardened and thermo-shrinkaging polymer products (films, tubes, fashioned products), production of radiation cross-linked polyethylene foam, technology of radiation vulcanization of elastomers. Attention is paid to radiation plants on the basis of γ-sources and electron acceleratos as well as to radiation conditions

  15. Harmonizing power cables and power lines. Harmonisierung der Starkstromkabel und -leitungen

    Energy Technology Data Exchange (ETDEWEB)

    Heinhold, L [Siemens A.G., Erlangen (Germany, F.R.); Retzlaff, E; Warner, A [Verband Deutscher Elektrotechniker (VDE) e.V., Frankfurt am Main (Germany, F.R.)

    1976-01-01

    The article gives a summarizing view of the present level of harmonization in the field of power cables and lines. Special attention is paid to problems referring to using harmonized designs for flexible lines and using lines for solid layout with PVC and rubber insulation in the German standards DIN 57281/VDE 0281 and DIN 57282/VDE 0282 and problems of taking the types used until today out of use. A general view of the power lines fully harmonized is given and a harmonization-labelling (common labelling) for cables and lines is described.

  16. Cellulose Insulation

    Science.gov (United States)

    1980-01-01

    Fire retardant cellulose insulation is produced by shredding old newspapers and treating them with a combination of chemicals. Insulating material is blown into walls and attics to form a fiber layer which blocks the flow of air. All-Weather Insulation's founders asked NASA/UK-TAP to help. They wanted to know what chemicals added to newspaper would produce an insulating material capable of meeting federal specifications. TAP researched the query and furnished extensive information. The information contributed to successful development of the product and helped launch a small business enterprise which is now growing rapidly.

  17. Water absorption and desorption in shuttle ablator and insulation materials

    Science.gov (United States)

    Whitaker, A. F.; Smith, C. F.; Wooden, V. A.; Cothren, B. E.; Gregory, H.

    1982-01-01

    Shuttle systems ablator and insulation materials underwent water soak with subsequent water desorption in vacuum. Water accumulation in these materials after a soak for 24 hours ranged from +1.1% for orbiter tile to +161% for solid rocket booster MSA-1. After 1 minute in vacuum, water retention ranged from none in the orbiter tile to +70% for solid rocket booster cork.

  18. Study of special spacer with damping device for suppressing wake galloping in tandem cables of cable-stayed bridges and its application to full scale bridge; Nendanseitai wo riyoshita heiretsu cable yo gensui kinotsuki spacer to sono jikkyo cable eno tekiyo ni kansuru kenkyu

    Energy Technology Data Exchange (ETDEWEB)

    Yoneda, M.; Setouchi, H.; Yoshioka, A. [Kawada Industries Inc., Tokyo (Japan); Shimoda, I.; Kawahara, S. [Oiles Corp., Tokyo (Japan)

    1996-12-20

    Cable vibration called wake galloping occurs in a cable-stayed bridge, in which cables are arranged tandem, and suppression of the vibration is an extremely important discussion item. This paper describes a complex eigen value analysis performed on tandem cables having lengths of 200 m and 100 m. The analysis revealed that damping characteristics added by a spacer system with a damping device (a type to install a visco-elastic body at about middle of the tandem cables via a jig) depend largely on torsional rigidity of the cables; and the characteristics may vary with difference in intervals between cable centers and that in cable diameters. A visco-elastic damping material of an asphalt system and a spacer with a damping device used as a spring material were fabricated and applied to a full scale bridge to identify quantitatively the damping addition characteristics of this system. Furthermore, the results of tests on the full scale bridge were compared with the result of the complex eigen value analysis, from which findings useful for actual works were obtained. 18 refs., 17 figs., 6 tabs.

  19. Study of Transient Heat Transport Mechanisms in Superfluid Helium Cooled Rutherford-Cables

    CERN Document Server

    AUTHOR|(CDS)2100615

    The Large Hadron Collider leverages superconducting magnets to focus the particle beam or keep it in its circular track. These superconducting magnets are composed of NbTi-cables with a special insulation that allows superfluid helium to enter and cool the superconducting cable. Loss mechanisms, e.g. continuous random loss of particles escaping the collimation system heating up the magnets. Hence, a local temperature increase can occur and lead to a quench of the magnets when the superconductor warms up above the critical temperature. A detailed knowledge about the temperature increases in the superconducting cable (Rutherford type) ensures a secure operation of the LHC. A sample of the Rutherford cable has been instrumented with temperature sensors. Experiments with this sample have been performed within this study to investigate the cooling performance of the helium in the cable due to heat deposition. The experiment uses a superconducting coil, placed in a cryostat, to couple with the magnetic field loss m...

  20. 46 CFR 111.60-5 - Cable installation.

    Science.gov (United States)

    2010-10-01

    ... REQUIREMENTS Wiring Materials and Methods § 111.60-5 Cable installation. (a) Each cable installation must meet... 46 Shipping 4 2010-10-01 2010-10-01 false Cable installation. 111.60-5 Section 111.60-5 Shipping... incorporated by reference; see 46 CFR 110.10-1), including clause 8. (b) Each cable installation made in...

  1. Surface Layer Fluorination-Modulated Space Charge Behaviors in HVDC Cable Accessory

    Directory of Open Access Journals (Sweden)

    Jin Li

    2018-05-01

    Full Text Available Space charges tend to accumulate on the surface and at the interface of ethylene–propylene–diene terpolymer (EPDM, serving as high voltage direct current (HVDC cable accessory insulation, which likely induces electrical field distortion and dielectric breakdown. Direct fluorination is an effective method to modify the surface characteristics of the EPDM without altering the bulk properties too much. In this paper, the surface morphology, hydrophobic properties, relative permittivity, and DC conductivity of the EPDM before and after fluorination treatment were tested. Furthermore, the surface and interface charge behaviors in the HVDC cable accessory were investigated by the pulsed electroacoustic (PEA method, and explained from the point of view of trap distribution. The results show that fluorination helps the EPDM polymer obtain lower surface energy and relative permittivity, which is beneficial to the interface match in composite insulation systems. The lowest degree of space charge accumulation occurs in EPDM with 30 min of fluorination. After analyzing the results of the 3D potentials and the density of states (DOS behaviors in EPDM before and after fluorination, it can be found that fluorination treatment introduces shallower electron traps, and the special electrostatic potential after fluorination can significantly suppress the space charge accumulation at the interface in the HVDC cable accessory.

  2. Accelerated Aging Effect on Epoxy-polysiloxane Polymeric Insulator Material with Rice Husk Ash Filler

    Directory of Open Access Journals (Sweden)

    Rochmadi .

    2012-12-01

    Full Text Available The performances of outdoor polymeric insulators are influenced by environmental conditions. This paper presents the effect of artificial tropical climate on the hydrophobicity, equivalent salt deposit density (ESDD, surface leakage current, flashover voltage, and surface degradation on epoxy-polysiloxane polymeric insulator materials with rice husk ash (RHA. Test samples are made at room temperature vulcanized (RTV of various composition of epoxy-polysiloxane with rice husk ash as filler. The aging was carried out in test chamber at temperature from 50oC to 62oC, relative humidity of 60% to 80%, and ultraviolet (UV  radiation 21.28 w/cm2 in daylight conditions for 96 hours. The experiment results showed that the flashover voltage fluctuates from 34.13 kV up to 40.92 kV and tends to decrease on each variation of material composition. The surface leakage current fluctuates and tends to increase. Test samples with higher filler content result greater hydrophobicity, smaller equivalent salt deposit density, and smaller critical leakage current, which caused the increase of the flashover voltage. Insulator material (RTVEP3 showed the best performance in tropical climate environment. Artificial tropical aging for short duration gives less effect to the surface degradation of epoxy-polysiloxane insulator material.

  3. Nanometric holograms based on a topological insulator material.

    Science.gov (United States)

    Yue, Zengji; Xue, Gaolei; Liu, Juan; Wang, Yongtian; Gu, Min

    2017-05-18

    Holography has extremely extensive applications in conventional optical instruments spanning optical microscopy and imaging, three-dimensional displays and metrology. To integrate holography with modern low-dimensional electronic devices, holograms need to be thinned to a nanometric scale. However, to keep a pronounced phase shift modulation, the thickness of holograms has been generally limited to the optical wavelength scale, which hinders their integration with ultrathin electronic devices. Here, we break this limit and achieve 60 nm holograms using a topological insulator material. We discover that nanometric topological insulator thin films act as an intrinsic optical resonant cavity due to the unequal refractive indices in their metallic surfaces and bulk. The resonant cavity leads to enhancement of phase shifts and thus the holographic imaging. Our work paves a way towards integrating holography with flat electronic devices for optical imaging, data storage and information security.

  4. Long-term Performance of PVC and CSPE Cables used in Nuclear Power Plants: the Effect of Degradation and Plasticizer migration

    International Nuclear Information System (INIS)

    Ekelund, Maria

    2009-10-01

    Enormous amounts of low voltage cables installed in a Swedish nuclear power plant are reaching their expected lifetimes. Since the cables are crucial to operational safety, it is of great importance that the actual condition of the installed cables is determined. In this study, cables based on poly(vinyl chloride) plasticized with di(2-ethylhexyl)phthalate (DEHP) were examined with respect to the degradation mechanisms responsible for the ageing of the insulation. This was achieved by studying samples that underwent accelerated ageing by different analytical methods, such as indenter modulus measurements, tensile testing, infrared spectroscopy, differential scanning calorimetry and liquid chromatography, to assess the condition of the cables. The results were unambiguous; the main deterioration mechanism differed for the jacket and the core insulation. The immediate increase in stiffness of the jacket insulation suggests that loss of plasticizer was the dominant cause for degradation. The core insulation on the other hand showed much smaller changes in the mechanical properties due to thermal ageing with an activation energy of the change in the indenter modulus matching that of the dehydrochlorination process. The electrical functionality during high-energy line break accident was correlated to the mechanical properties of the cable and this correlation was used to establish a lifetime criterion. The mechanical data showed Arrhenius temperature dependence with activation energies of 80 kJ/mol and 100 kJ/mol for the jacketing and 130 kJ/mol for the core insulation. These activation energies were used to extrapolate the lifetimes to service temperatures (20 deg C to 50 deg C). Plasticizer migration was determined as the lifetime controlling mechanism at the service temperatures. Experimental data, obtained by extraction of DEHP followed by liquid chromatography, were analysed by numerical methods to gain a better understanding of the migration. The analysis showed

  5. Long-term Performance of PVC and CSPE Cables used in Nuclear Power Plants: the Effect of Degradation and Plasticizer migration

    Energy Technology Data Exchange (ETDEWEB)

    Ekelund, Maria

    2009-10-15

    Enormous amounts of low voltage cables installed in a Swedish nuclear power plant are reaching their expected lifetimes. Since the cables are crucial to operational safety, it is of great importance that the actual condition of the installed cables is determined. In this study, cables based on poly(vinyl chloride) plasticized with di(2-ethylhexyl)phthalate (DEHP) were examined with respect to the degradation mechanisms responsible for the ageing of the insulation. This was achieved by studying samples that underwent accelerated ageing by different analytical methods, such as indenter modulus measurements, tensile testing, infrared spectroscopy, differential scanning calorimetry and liquid chromatography, to assess the condition of the cables. The results were unambiguous; the main deterioration mechanism differed for the jacket and the core insulation. The immediate increase in stiffness of the jacket insulation suggests that loss of plasticizer was the dominant cause for degradation. The core insulation on the other hand showed much smaller changes in the mechanical properties due to thermal ageing with an activation energy of the change in the indenter modulus matching that of the dehydrochlorination process. The electrical functionality during high-energy line break accident was correlated to the mechanical properties of the cable and this correlation was used to establish a lifetime criterion. The mechanical data showed Arrhenius temperature dependence with activation energies of 80 kJ/mol and 100 kJ/mol for the jacketing and 130 kJ/mol for the core insulation. These activation energies were used to extrapolate the lifetimes to service temperatures (20 deg C to 50 deg C). Plasticizer migration was determined as the lifetime controlling mechanism at the service temperatures. Experimental data, obtained by extraction of DEHP followed by liquid chromatography, were analysed by numerical methods to gain a better understanding of the migration. The analysis showed

  6. Panels of microporous insulation

    Energy Technology Data Exchange (ETDEWEB)

    McWilliams, J.A.; Morgan, D.E.; Jackson, J.D.J.

    1990-08-07

    Microporous thermal insulation materials have a lattice structure in which the average interstitial dimension is less than the mean free path of the molecules of air or other gas in which the material is arranged. This results in a heat flow which is less than that attributable to the molecular heat diffusion of the gas. According to this invention, a method is provided for manufacturing panels of microporous thermal insulation, in particular such panels in which the insulation material is bonded to a substrate. The method comprises the steps of applying a film of polyvinyl acetate emulsion to a non-porous substrate, and compacting powdery microporous thermal insulation material against the film so as to cause the consolidated insulation material to bond to the substrate and form a panel. The polyvinyl acetate may be applied by brushing or spraying, and is preferably allowed to dry prior to compacting the insulation material. 1 fig.

  7. BC Hydro's integrated approach on replacing underground feeder cables

    Energy Technology Data Exchange (ETDEWEB)

    Tarampi, D. [BC Hydro, Burnaby, BC (Canada)

    2008-07-01

    BC Hydro's integrated approach on replacing underground feeder cables was discussed. The feeder cables were all in ducts encased in concrete and splices were identified in concrete manholes. The feeder cables averaged 35 to 40 failures per year, with a large majority of failures occurring in manholes or near terminations. The age of the cables was not known. A graphical representation of a condition assessment was presented with reference to an electrical test, metallurgical test, hardness test, and dye penetrating test. Prioritization steps were also listed, including a condition index and replacement threshold. Steps in prioritizing the condition index included determining the insulation index based on electrical test results; determining the manhole condition based on metallurgical test results; determining the customer importance factor and feeder load factor; and calculating the overall condition index based on the indices. A process flowchart was also illustrated. A replacement strategy was then discussed and a cost comparison of two options was described. Option 1 was to replace only the unjacketed cables while option two involved selective replacement. tabs., figs.

  8. A Study on the Measurement of Ultrasound Velocity to Evaluate Degradation of Low Voltage Cables for Nuclear Power Plants

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Kyung Cho; Kang, Suk Chull; Goo, Cheol Soo [Korea Institute of Nuclear Safety, Daejeon (Korea, Republic of); Kim, Jin Ho; Park, Jae Seok; Joo, Geum Jong; Park, Chi Seung [KAITEC, Seoul (Korea, Republic of)

    2004-08-15

    Several kinds of low voltage cables have been used in nuclear power plants for the supply of electric power, supervision, and the propagation of control signals. These low voltage tables must be inspected for safe and stable operation of nuclear power plants. In particular, the degradation diagnosis to estimate the integrity of low voltage rabies has recently been emphasized according to the long use of nuclear power plants. In order to evaluate their degradation, the surrounding temperature, hardness of insulation material, elongation at breaking point (EAB), etc. have been used. However, the measurement of temperature or hardness is not useful because of the absence of quantitative criteria; the inspection of a sample requires turning off of the power plant power; and, the electrical inspection method is not sufficiently sensitive from the initial through the middle stage of degradation. In this research, based on the theory that the ultrasonic velocity changes with relation to the degradation of the material, we measured the ultrasonic velocity as low voltage cables were degraded. To this end, an ultrasonic degradation diagnosis device was developed and used to measure the ultrasonic velocity with the clothing on the cable, and it was confirmed that the ultrasonic velocity changes according to the degradation of low voltage cables. The low voltage cables used in nuclear power plants were degraded at an accelerated rate, and EAB was measured in a tensile test conducted after the measurement of ultrasonic velocity. With the increasing degradation degree, the ultrasonic velocity decreased, whose potential as a useful parameter for the quantitative degradation evaluation was thus confirmed

  9. Modeling thermal performance of exterior walls retrofitted from insulation and modified laterite based bricks materials

    Science.gov (United States)

    Wati, Elvis; Meukam, Pierre; Damfeu, Jean Claude

    2017-12-01

    Uninsulated concrete block walls commonly found in tropical region have to be retrofitted to save energy. The thickness of insulation layer used can be reduced with the help of modified laterite based bricks layer (with the considerably lower thermal conductivity than that of concrete block layer) during the retrofit building fabrics. The aim of this study is to determine the optimum location and distribution of different materials. The investigation is carried out under steady periodic conditions under the climatic conditions of Garoua in Cameroon using a Simulink model constructed from H-Tools (the library of Simulink models). Results showed that for the continuous air-conditioned space, the best wall configuration from the maximum time lag, minimum decrement factor and peak cooling transmission load perspective, is dividing the insulation layer into two layers and placing one at the exterior surface and the other layer between the two different massive layers with the modified laterite based bricks layer at the interior surface. For intermittent cooling space, the best wall configuration from the minimum energy consumption depends on total insulation thickness. For the total insulation thickness less than 8 cm approximately, the best wall configuration is placing the half layer of insulation material at the interior surface and the other half between the two different massive layers with the modified earthen material at the exterior surface. Results also showed that, the optimum insulation thickness calculated from the yearly cooling transmission (estimated only during the occupied period) and some economic considerations slightly depends on the location of that insulation.

  10. Trend analysis of cables failure events at nuclear power plants

    International Nuclear Information System (INIS)

    Fushimi, Yasuyuki

    2007-01-01

    In this study, 152 failure events related with cables at overseas nuclear power plants are selected from Nuclear Information Database, which is owned by The Institute of Nuclear Safety System, and these events are analyzed in view of occurrence, causal factor, and so on. And 15 failure events related with cables at domestic nuclear power plants are selected from Nuclear Information Archives, which is owned by JANTI, and these events are analyzed by the same manner. As a result of comparing both trends, it is revealed following; 1) A cable insulator failure rate is lower at domestic nuclear power plants than at foreign ones. It is thought that a deterioration diagnosis is performed broadly in Japan. 2) Many buried cables failure events have been occupied a significant portion of cables failure events during work activity at overseas plants, however none has been occurred at domestic plants. It is thought that sufficient survey is conducted before excavating activity in Japan. 3) A domestic age related cables failure rate in service is lower than the overseas one and domestic improper maintenance rate is higher than the overseas one. Maintenance worker' a skill improvement is expected in order to reduce improper maintenance. (author)

  11. Opportunities in chemistry and materials science for topological insulators and their nanostructures

    KAUST Repository

    Kong, Desheng

    2011-10-24

    Electrical charges on the boundaries of topological insulators favour forward motion over back-scattering at impurities, producing low-dissipation, metallic states that exist up to room temperature in ambient conditions. These states have the promise to impact a broad range of applications from electronics to the production of energy, which is one reason why topological insulators have become the rising star in condensed-matter physics. There are many challenges in the processing of these exotic materials to use the metallic states in functional devices, and they present great opportunities for the chemistry and materials science research communities. © 2011 Macmillan Publishers Limited. All rights reserved.

  12. Insulation Cork Boards—Environmental Life Cycle Assessment of an Organic Construction Material

    Science.gov (United States)

    Silvestre, José D.; Pargana, Nuno; de Brito, Jorge; Pinheiro, Manuel D.; Durão, Vera

    2016-01-01

    Envelope insulation is a relevant technical solution to cut energy consumption and reduce environmental impacts in buildings. Insulation Cork Boards (ICB) are a natural thermal insulation material whose production promotes the recycling of agricultural waste. The aim of this paper is to determine and evaluate the environmental impacts of the production, use, and end-of-life processing of ICB. A “cradle-to-cradle” environmental Life Cycle Assessment (LCA) was performed according to International LCA standards and the European standards on the environmental evaluation of buildings. These results were based on site-specific data and resulted from a consistent methodology, fully described in the paper for each life cycle stage: Cork oak tree growth, ICB production, and end-of-life processing-modeling of the carbon flows (i.e., uptakes and emissions), including sensitivity analysis of this procedure; at the production stage—the modeling of energy processes and a sensitivity analysis of the allocation procedures; during building operation—the expected service life of ICB; an analysis concerning the need to consider the thermal diffusivity of ICB in the comparison of the performance of insulation materials. This paper presents the up-to-date “cradle-to-cradle” environmental performance of ICB for the environmental categories and life-cycle stages defined in European standards. PMID:28773516

  13. Insulation Cork Boards-Environmental Life Cycle Assessment of an Organic Construction Material.

    Science.gov (United States)

    Silvestre, José D; Pargana, Nuno; de Brito, Jorge; Pinheiro, Manuel D; Durão, Vera

    2016-05-20

    Envelope insulation is a relevant technical solution to cut energy consumption and reduce environmental impacts in buildings. Insulation Cork Boards (ICB) are a natural thermal insulation material whose production promotes the recycling of agricultural waste. The aim of this paper is to determine and evaluate the environmental impacts of the production, use, and end-of-life processing of ICB. A "cradle-to-cradle" environmental Life Cycle Assessment (LCA) was performed according to International LCA standards and the European standards on the environmental evaluation of buildings. These results were based on site-specific data and resulted from a consistent methodology, fully described in the paper for each life cycle stage: Cork oak tree growth, ICB production, and end-of-life processing-modeling of the carbon flows ( i.e. , uptakes and emissions), including sensitivity analysis of this procedure; at the production stage-the modeling of energy processes and a sensitivity analysis of the allocation procedures; during building operation-the expected service life of ICB; an analysis concerning the need to consider the thermal diffusivity of ICB in the comparison of the performance of insulation materials. This paper presents the up-to-date "cradle-to-cradle" environmental performance of ICB for the environmental categories and life-cycle stages defined in European standards.

  14. Insulation Cork Boards—Environmental Life Cycle Assessment of an Organic Construction Material

    Directory of Open Access Journals (Sweden)

    José D. Silvestre

    2016-05-01

    Full Text Available Envelope insulation is a relevant technical solution to cut energy consumption and reduce environmental impacts in buildings. Insulation Cork Boards (ICB are a natural thermal insulation material whose production promotes the recycling of agricultural waste. The aim of this paper is to determine and evaluate the environmental impacts of the production, use, and end-of-life processing of ICB. A “cradle-to-cradle” environmental Life Cycle Assessment (LCA was performed according to International LCA standards and the European standards on the environmental evaluation of buildings. These results were based on site-specific data and resulted from a consistent methodology, fully described in the paper for each life cycle stage: Cork oak tree growth, ICB production, and end-of-life processing-modeling of the carbon flows (i.e., uptakes and emissions, including sensitivity analysis of this procedure; at the production stage—the modeling of energy processes and a sensitivity analysis of the allocation procedures; during building operation—the expected service life of ICB; an analysis concerning the need to consider the thermal diffusivity of ICB in the comparison of the performance of insulation materials. This paper presents the up-to-date “cradle-to-cradle” environmental performance of ICB for the environmental categories and life-cycle stages defined in European standards.

  15. Design of a termination for a high temperature superconduction power cable

    DEFF Research Database (Denmark)

    Rasmussen, Carsten; Kühle (fratrådt), Anders Van Der Aa; Tønnesen, Ole

    1999-01-01

    ). This assembly is electrically insulated with an extruded polymer dielectric kept at room temperature. Cooling is provided by a flow of liquid nitrogen inside the former. The purpose of the termination is to connect the superconducting cable conductor at cryogenic temperature to the existing power grid at room...... temperatures, the transfer of liquid nitrogen over a high voltage drop and that of providing a well defined atmosphere inside the termination and around the cable conductor. Designs based on calculations and experiments will be presented. The solutions are optimized with respect to a low heat in-leak....

  16. Evaluation of the Cable Types for Safety Requirements during Fire Conditions in Nuclear Facility

    International Nuclear Information System (INIS)

    Al-kattan, W.A.

    2015-01-01

    In Nuclear Power Plants (NPPs), the fire in cables causes many dangerous events in electrical or mechanical operations causing a nuclear reactor melt down. Main Control Room (MCR) in nuclear power plants have therefore, special concern in the fire protection systems. The Nuclear International Atomic Energy Agency (IAEA) has promoted the use of risk-informed and performance based methods for fire protection. These methods affirm the relevant needs to develop realistic methods to quantify the risk of fire to NPPs safety. The recent electrical cable testing has been carried out to provide empirical data on the failure modes and likelihood of fire-induced damage. In this thesis, will use fire modeling to develop fire probabilistic safety assessment to estimate the likelihood of fire induced cable damage given a specified fire profile. The objective of this work is to provide a comprehensive evaluation of the most recent fire-induced circuit failure due to different cables type that used inside the NPPs by simulation using fire modeling. One of this work scope is to suggest a suitable cable insulation material especially in case of the thermal failure thresholds, for developing the electrical cable thermal fragility distributions and evaluate parameters that influence fire-induced circuit failure modes. The main control room is implementing using the CFAST (fire simulation package). The simulation results represent the full development fire temperature and heat flux as well as the output gases. The results can be used as the basic parameters of the cables comparison and then evaluation.The importance of these results are not only for evaluating the cables but one can efficiently use them to improve the whole NPPs safety levels. The gases results of the fire simulation inside the room are oxygen, carbon monoxide, carbon dioxide, and hydrogen chloride. These gases are being used lot achieving the healthy protection of NPPs. Finally, one can measure the healthy environment

  17. Effect on the insulation material of a MOSFET device submitted to a standard diagnostic radiation beam

    International Nuclear Information System (INIS)

    De Magalhaes, C M S; Dos Santos, L A P; Souza, D do N; Maia, A F

    2010-01-01

    MOSFET electronic devices have been used for dosimetry in radiology and radiotherapy. Several communications show that due to the radiation exposure defects appear on the semiconductor crystal lattice. Actually, the structure of a MOSFET consists of three materials: a semiconductor, a metal and an insulator between them. The MOSFET is a quadripolar device with a common terminal: gate-source is the input; drain-source is the output. The gate controls the electrical current passing through semiconductor medium by the field effect because the silicon oxide acts as insulating material. The proposal of this work is to show some radiation effects on the insulator of a MOSFET device. A 6430 Keithley sub-femtoamp SourceMeter was used to verify how the insulating material layer in the structure of the device varies with the radiation exposure. We have used the IEC 61267 standard radiation X-ray beams generated from a Pantak industrial unit in the radiation energy range of computed tomography. This range was chosen because we are using the MOSFET device as radiation detector for dosimetry in computed tomography. The results showed that the behaviour of the electrical current of the device is different in the insulator and semiconductor structures.

  18. Production of a nuclear radiation resistant and mechanically tough electrically insulating material

    International Nuclear Information System (INIS)

    Brechna, H.

    1975-01-01

    According to the invention, an electrically insulating material of high mechanical strength and resistance to nuclear radiation may be made of a hardenable plastic material coated on an inorganic supporting tissue. The synthetic resin serving as binder - duroplasts, e.g. epoxide resins, polyester resins or silicon resins - is heated, mixed with a catalyst, a wetting agent and a filler (and, if required, with 0.5-1.5 weight % thixotropic material) and coated, under reduced pressure (o.4 to 0.6 mm Hg), on the supporting tissue whose surface is cleaned before this by heating. It is then hardened. Hardening may also take place directly on the electric conductor to be insulated. One obtains a bubble-free wire coating. The inorganic supporting material is glas fibre tissue, also in combination with mica, while Al 2 O 3 , zirconium, zirconia, magnesium oxide, mica and silica (grain size 10-20 μ). The invention is illustrated by a number of examples. (UWI) [de

  19. Report of the 13th IEA workshop on radiation effects in ceramic insulators

    International Nuclear Information System (INIS)

    2004-03-01

    The 13th IEA Workshop on Radiation Effects in Ceramic Insulators, based on Annex II: Experimentation on Radiation Damage in Fusion Materials, to the IEA Implementing Agreement for a Programme of Research and Development on Radiation Damage in Fusion Materials, was held on the 9th, December, 2003, at Kyoto International Conference Center, in Kyoto, Japan, in conjunction with the 11th International Conference on Fusion Reactor Materials (ICFRM-11). 44 participants from 10 countries (26 from Japan, 5 from Spain, 3 from Belgium, 3 from USA, 2 from RF, each 1 from Austria, Greece, Italy, Romania, and UK) gathered together and discussed following issues extensively, with the newest experimental results, after the welcome remarks by one of the organizer and chairpersons, Dr. E.R. Hodgson of CIEMAT. Effects of electric field on radiation induced microstructural evolution, parasitic electrical current and voltage induced in cables and wires by radiation effects, optical materials, IFMIF related issues and fundamental aspects were discussed. Significant results such as an observation of γ-alumina and aluminum colloid formation for the Radiation Induced Electrical Degradation mechanism are obtained. This report is workshop summary, abstracts and documents of the 13th IEA Workshop on Radiation Effects in Ceramic Insulators. (author)

  20. A Difference in Using Atomic Layer Deposition or Physical Vapour Deposition TiN as Electrode Material in Metal-Insulator-Metal and Metal-Insulator-Silicon Capacitors

    NARCIS (Netherlands)

    Groenland, A.W.; Wolters, Robertus A.M.; Kovalgin, Alexeij Y.; Schmitz, Jurriaan

    2011-01-01

    In this work, metal-insulator-metal (MIM) and metal-insulator-silicon (MIS) capacitors are studied using titanium nitride (TiN) as the electrode material. The effect of structural defects on the electrical properties on MIS and MIM capacitors is studied for various electrode configurations. In the

  1. USING CONDITION MONITORING TO PREDICT REMAINING LIFE OF ELECTRIC CABLES

    International Nuclear Information System (INIS)

    LOFARO, R.; SOO, P.; VILLARAN, M.; GROVE, E.

    2001-01-01

    Electric cables are passive components used extensively throughout nuclear power stations to perform numerous safety and non-safety functions. It is known that the polymers commonly used to insulate the conductors on these cables can degrade with time; the rate of degradation being dependent on the severity of the conditions in which the cables operate. Cables do not receive routine maintenance and, since it can be very costly, they are not replaced on a regular basis. Therefore, to ensure their continued functional performance, it would be beneficial if condition monitoring techniques could be used to estimate the remaining useful life of these components. A great deal of research has been performed on various condition monitoring techniques for use on electric cables. In a research program sponsored by the U.S. Nuclear Regulatory Commission, several promising techniques were evaluated and found to provide trendable information on the condition of low-voltage electric cables. These techniques may be useful for predicting remaining life if well defined limiting values for the aging properties being measured can be determined. However, each technique has advantages and limitations that must be addressed in order to use it effectively, and the necessary limiting values are not always easy to obtain. This paper discusses how condition monitoring measurements can be used to predict the remaining useful life of electric cables. The attributes of an appropriate condition monitoring technique are presented, and the process to be used in estimating the remaining useful life of a cable is discussed along with the difficulties that must be addressed

  2. Dielectric strength behaviour and mechanical properties of transparent insulation materials suitable to optical monitoring of partial discharges

    International Nuclear Information System (INIS)

    Lothongkam, Chaiyaporn

    2014-01-01

    statistical analysis based on the 2-parameter Weibull distribution function. The investigations revealed that the virgin translucent silicone rubber has a large elastic region with an acceptable plastic deformation and also provides an AC 50 Hz dielectric strength of approximately 24 kV/mm for 0.5 mm thickness. These values enable considering the tested translucent silicone as replacement material for an opaque elastomer that is currently used for a rubber stress cone of HV cable accessories.. Unfortunately, its optical transmittance is poor compared to optically clear transparent silicone rubbers. On the other hand, the mechanical properties of virgin transparent silicone rubbers do not comply with those demanded from push-on stress cones. In particular, their elongation at break is considered too low for that application. However they provide the AC dielectric strength values in either 28 kV/mm or 29 kV/mm for 0.5 mm thickness, which are higher than those of the translucent type. Moreover, it was found that the post-curing process does not provide a positive impact on the ultimate elongation of silicone rubbers. Hence, the elongation at break of virgin transparent silicone rubbers must be improved before they can be used as insulating material for a rubber stress cone. In addition, the influence of mechanical tensile stress on the dielectric strength of the virgin translucent silicone rubber was investigated. The results show that mechanical tensile stress does not negatively influence on dielectric strength of such silicone rubber, so it can be well-operated under combined electrical and mechanical stresses. Beside the improvement of optical PD detection performance in the translucent silicone insulation materials, the influence of fluorescent dye's modification was investigated. The results indicate that the commercially available fluorescent dyes of 0.02 wt. % mixed into the translucent silicone polymer do not negatively influence on the E b value of such silicone

  3. Novel Application of Glass Fibers Recovered From Waste Printed Circuit Boards as Sound and Thermal Insulation Material

    Science.gov (United States)

    Sun, Zhixing; Shen, Zhigang; Ma, Shulin; Zhang, Xiaojing

    2013-10-01

    The aim of this study is to investigate the feasibility of using glass fibers, a recycled material from waste printed circuit boards (WPCB), as sound absorption and thermal insulation material. Glass fibers were obtained through a fluidized-bed recycling process. Acoustic properties of the recovered glass fibers (RGF) were measured and compared with some commercial sound absorbing materials, such as expanded perlite (EP), expanded vermiculite (EV), and commercial glass fiber. Results show that RGF have good sound absorption ability over the whole tested frequency range (100-6400 Hz). The average sound absorption coefficient of RGF is 0.86, which is prior to those of EP (0.81) and EV (0.73). Noise reduction coefficient analysis indicates that the absorption ability of RGF can meet the requirement of II rating for sound absorbing material according to national standard. The thermal insulation results show that RGF has a fair low thermal conductivity (0.046 W/m K), which is comparable to those of some insulation materials (i.e., EV, EP, and rock wool). Besides, an empirical dependence of thermal conductivity on material temperature was determined for RGF. All the results showed that the reuse of RGF for sound and thermal insulation material provided a promising way for recycling WPCB and obtaining high beneficial products.

  4. The design and management of cables and supporting steelwork systems for Sizewell 'B'

    International Nuclear Information System (INIS)

    Kerry, L.P.

    1992-01-01

    Sizewell B Power Station has over 33,000 cables connecting in excess of 20,000 items of equipment. Over 120 cable types are used. Many cables supply power to, or monitor, safety category 1 equipment essential to the safe operation of the Reactor and supporting systems. Cables must be designed to survive the postulated hazards of Reactor systems fault, earthquake, fire and radiation exposure. The cable network is the nerve system of the station; its role is to distribute electrical power and control indication, metering and protection signals to the various items of plant and equipment under normal and emergency operating conditions. To perform these functions satisfactorily a new range of cable insulations had to be developed and supporting steelwork designed to withstand the effect of an earthquake. The 63 month Sizewell B construction programme means record cable laying and completion rates have to be achieved needing careful and detailed planning from design to installation. As with electrical equipment, cables are designated either essential (to Reactor safety operation) or non-essential. This paper describes the required safety design criteria, how these are achieved and the design approaches to seismically qualified supporting steelwork. Also described are the cable design, scheduling, routing and planning processes which lead to the required installation and commissioning activities being completed in a controlled and timely manner. (Author)

  5. Mass loss and flammability of insulation materials used in sandwich panels during the pre-flashover phase of fire

    NARCIS (Netherlands)

    Giunta d'Albani, A.W.; de Kluiver, L.L.; de Korte, A.C.J.; van Herpen, R.; Weewer, R.; Brouwers, H.J.H.

    2017-01-01

    Nowadays, buildings contain more and more synthetic insulation materials in order to meet the increasing energy-performance demands. These synthetic insulation materials have a different response to fire. In this study, the mass loss and flammability limits of different sandwich panels and their

  6. Ethylene propylene cable degradation during LOCA research tests: tensile properties at the completion of accelerated aging

    International Nuclear Information System (INIS)

    Bustard, L.D.

    1982-05-01

    Six ethylene-propylene rubber (EPR) insulation materials were aged at elevated temperature and radiation stress exposures common in cable LOCA qualification tests. Material samples were subjected to various simultaneous and sequential aging simulations in preparation for accident environmental exposures. Tensile properties subsequent to the aging exposure sequences are reported. The tensile properties of some, but not all, specimens were sensitive to the order of radiation and elevated temperature stress exposure. Other specimens showed more severe degradation when simultaneously exposed to radiation and elevated temperature as opposed to the sequential exposure to the same stresses. Results illustrate the difficulty in defining a single test procedure for nuclear safety-related qualification of EPR elastomers. A common worst-case sequential aging sequence could not be identified

  7. Safeguarding of emergency core cooling in case of loss-of-coolant accidents with insulation material release

    International Nuclear Information System (INIS)

    Pointner, W.; Broecker, A.

    2012-01-01

    The report on safeguarding of emergency core cooling in case of loss-of-coolant accidents with insulation material release covers the following issues: assessment of the relevant status for PWR, evaluation of the national and international (USA, Canada, France) status, actualization of recommendations, transferability from PWR to BWR. Generic studies on the core cooling capability in case of insulation material release in BWR-type reactors were evaluated.

  8. Detail of photo 7903109 stack of superconducting cables in the modulus measuring device

    CERN Multimedia

    CERN PhotoLab

    1979-01-01

    The picture shows an assembly of insulated superconducting cables of the type used in the Po dipole magnet inserted in the elastic modulus measuring device (photos 7903547X and 7903169) in order to measures its mechanical properties under azimuthal compression. See also 7903547X, 7903169, 8307552X.

  9. Design of a 30 m long 1 kA 10 kV YBCO cable

    Energy Technology Data Exchange (ETDEWEB)

    Rostila, L [Institute of Electromagnetics, Tampere University of Technology, PO Box 692, FIN-33101 Tampere (Finland); Lehtonen, J [Institute of Electromagnetics, Tampere University of Technology, PO Box 692, FIN-33101 Tampere (Finland); Masti, M [Institute of Electromagnetics, Tampere University of Technology, PO Box 692, FIN-33101 Tampere (Finland); Lallouet, N [Nexas France, rue Mozart 4-10, 92587 Clichy (France); Saugrain, J-M [Nexas France, rue Mozart 4-10, 92587 Clichy (France); Allais, A [Nexans Deutschland Industries GmbH and Co. KG, Kabelkamp 20, D-30179 Hannover (Germany); Schippl, K [Nexans Deutschland Industries GmbH and Co. KG, Kabelkamp 20, D-30179 Hannover (Germany); Schmidt, F [Nexans Deutschland Industries GmbH and Co. KG, Kabelkamp 20, D-30179 Hannover (Germany); Balog, G [Nexans Norway, PO Box 6450, Etterstad, N-0605, Oslo, Norway (Norway); Marot, G [Air Liquide DTA, 2 rue de Clemenciere BP15, 38360 Sassenage (France); Ravex, A [Air Liquide DTA, 2 rue de Clemenciere BP15, 38360 Sassenage (France); Usoskin, A [European High Temperature Superconductors Gmbh and Co. KG, Windausweg 2, 37037 Goettingen (Germany); Goemoery, F [Institute of Electrical Engineering, Slovak Academy of Sciences, Dubravska cesta 9, 84104 Bratislava (Slovakia); Klincok, B [Institute of Electrical Engineering, Slovak Academy of Sciences, Dubravska cesta 9, 84104 Bratislava (Slovakia); Souc, J [Institute of Electrical Engineering, Slovak Academy of Sciences, Dubravska cesta 9, 84104 Bratislava (Slovakia); Freyhardt, H C [Institute of Materialphysic, University of Goettingen, Friedrich-Hund-Platz 1, D-37077 Goettingen (Germany)

    2006-04-15

    In this paper a 30 m long one-phase coaxial YBCO cable with 1 kA transport current and 10 kV operating voltage was designed for the Super3C project to check the feasibility of YBCO tapes for low-loss cables. The final design incorporates cryogenic, mechanical and electromagnetic aspects. The electromagnetic losses during normal operation must be minimized. The cryogenic design must also take into account the generation of heat during short circuit conditions. Mechanical restrictions set the minimum gaps between the coated conductor tapes and the minimum lay angles in order to make the cabling feasible and to enable handling of the cable. The design of the electric insulation should be according to the international standard as far as applicable. The final design has to take into account all of the above restrictions.

  10. Design of a 30 m long 1 kA 10 kV YBCO cable

    International Nuclear Information System (INIS)

    Rostila, L; Lehtonen, J; Masti, M; Lallouet, N; Saugrain, J-M; Allais, A; Schippl, K; Schmidt, F; Balog, G; Marot, G; Ravex, A; Usoskin, A; Goemoery, F; Klincok, B; Souc, J; Freyhardt, H C

    2006-01-01

    In this paper a 30 m long one-phase coaxial YBCO cable with 1 kA transport current and 10 kV operating voltage was designed for the Super3C project to check the feasibility of YBCO tapes for low-loss cables. The final design incorporates cryogenic, mechanical and electromagnetic aspects. The electromagnetic losses during normal operation must be minimized. The cryogenic design must also take into account the generation of heat during short circuit conditions. Mechanical restrictions set the minimum gaps between the coated conductor tapes and the minimum lay angles in order to make the cabling feasible and to enable handling of the cable. The design of the electric insulation should be according to the international standard as far as applicable. The final design has to take into account all of the above restrictions

  11. Development of advanced material composites for use as internal insulation for LH2 tanks (gas layer concept)

    Science.gov (United States)

    Gille, J. P.

    1972-01-01

    A program is described that was conducted to develop an internal insulation system for potential application to the liquid hydrogen tanks of a reusable booster, where the tanks would be subjected to repeated high temperatures. The design of the internal insulation is based on a unique gas layer concept, in which capillary or surface tension effects are used to maintain a stable gas layer, within a cellular core structure, between the tank wall and the contained liquid hydrogen. Specific objectives were to select materials for insulation systems that would be compatible with wall temperatures of 350 F and 650 F during reentry into the earth's atmosphere, and to fabricate and test insulation systems under conditions simulating the operating environment. A materials test program was conducted to evaluate the properties of candidate materials at elevated temperatures and at the temperature of liquid hydrogen, and to determine the compatibility of the materials with a hydrogen atmosphere at the appropriate elevated temperature. The materials that were finally selected included Kapton polyimide films, silicone adhesives, fiber glass batting, and in the case of the 350 F system, Teflon film.

  12. Setting of loose-fill insulation materials in walls; Saetningsfri indblaesning af loesfyldsisolering i vaegge

    Energy Technology Data Exchange (ETDEWEB)

    Rasmussen, T.V.

    2001-07-01

    The report describes material behaviour, which significantly influences the settling of loose-fill insulation materials. The specific application presented here is loose-fill insulation material injected in walls as thermal insulation. The physical formulation of the issue to be discussed is that the mass is kept in position in the cavity by frictional forces, which counteracts the settling but complicates injection. The purpose of this study is to investigate whether there is a possibility that decreased friction will be able to release settling. Cellulose loose-fill material injected in a 0.1 m thick and 1 m wide gypsum wall with a minimum density of 48 kg/m3 was found not to settle if kept at a constant relative humidity, RH 50 %. A minimum density of 53 kg/m3 is necessary if the thickness of the wall is increased from 0.1 m to 0.3 m. If changing the constant environment from RH 50 % to RH 80 % a minimum density of 63 kg/m3 is necessary. Furthermore, results so far show that cellulose loose-fill material spread on the attic floor will have a density after settling of 48 kg /M3 for a constant RH 50 %, corresponding to 43 kg/m3 dry material. The results were found by using a model and tests. (au)

  13. Reduction of heat insulation upon soaking of the insulation layer

    Science.gov (United States)

    Achtliger, J.

    1983-09-01

    Improved thermal protection of hollow masonry by introduction of a core insulation between the inner and outer shell is discussed. The thermal conductivity of insulation materials was determined in dry state and after soaking by water with different volume-related moisture contents. The interpolated thermal conductivity values from three measured values at 10 C average temperature are presented as a function of the pertinent moisture content. Fills of expanded polystyrene, perlite and granulated mineral fibers, insulating boards made of mineral fibers and in situ cellular plastics produced from urea-formaldehyde resin were investigated. Test results show a confirmation of thermal conductivity values for insulating materials in hollow masonry.

  14. INSUL, Calculation of Thermal Insulation of Various Materials Immersed in He

    International Nuclear Information System (INIS)

    Kinkead, A.N.; Pitchford, B.E.

    1977-01-01

    1 - Nature of the physical problem solved: Performance of thermal insulation immersed in helium. 2 - Method of solution: Mineral fibre, metal fibre and metallic multi-layer foils are studied. An approximate analysis for performance evaluation of multi-layer insulation in vertical gas spaces including the regime between fully suppressed natural convection and that for which an accepted power relationship applies is included

  15. Polyester Apparel Cutting Waste as Insulation Material

    OpenAIRE

    Trajković, Dušan; Jordeva, Sonja; Tomovska, Elena; Zafirova, Koleta

    2017-01-01

    Polyester waste is the dominant component of the clothing industry waste stream, yet its recycling in this industry is rarely addressed. This paper proposes using polyester cutting waste as an insulation blanket for roofing and buildings’ internal walls in order to reduce environmental pollution. The designed textile structures used waste cuttings from different polyester fabrics without opening the fabric to fibre. Thermal insulation, acoustic insulation, fire resistance and biodegradation o...

  16. AC over-current characteristics of YBCO coated conductor with copper stabilizer layer considering insulation layer

    International Nuclear Information System (INIS)

    Du, H.-I.; Kim, M.-J.; Kim, Y.-J.; Lee, D.-H.; Han, B.-S.; Song, S.-S.

    2010-01-01

    Compared with the first-generation BSCCO wire, the YBCO thin-film wire boasts low material costs and high J c and superior magnetic-field properties, among other strengths. Meanwhile, the previous BSCCO wire material for superconducting cables has been researched on considerably with regard to its post-wire quenching characteristics during the application of an alternating over-current. In this regard, the promising YBCO thin-film wire has yet to be further researched on. Moreover, still lacking is research on the YBCO thin-film wire with insulating layers, which is essential in the manufacture of superconducting cables, along with the testing of the application of an alternating over-current to the wire. In this study, YBCO thin-film wires with copper-stabilizing layers were used in testing alternating over-current application according to the presence or absence of insulating layers and to the thickness of such layers, to examine the post-quenching wire resistance increase and quenching trends. The YBCO thin-film wire with copper-stabilizing layers has a critical temperature of 90 K and a critical current of 85 A rms . Moreover, its current application cycle is 5.5 cycles, and its applied currents are 354, 517, 712, and 915 A peak . These figures enabled the YBCO thin-film wires with copper-stabilizing layers to reach 90, 180, 250, and 300 K, respectively, in this study. These temperatures serve as a relative reference to examine the post-quenching wire properties following the application of an alternating over-current.

  17. Experimental performance evaluation of solid concrete and dry insulation materials for passive buildings in hot and humid climatic conditions

    International Nuclear Information System (INIS)

    Rehman, Hassam Ur

    2017-01-01

    Highlights: • Experimental investigation of building insulation materials in UAE from 2012–2014. • Four same calorimeters with different south walls were built in open air laboratory. • Heat flux was reduced by 22–75% in steady state analysis during summer by insulation. • Hence, energy consumption for cooling was reduced by an average 7.6–25.3%. • Heat flow was steady in free floating analysis in winter through insulated walls. - Abstract: It is known that enhancement of building energy efficiency can help in reducing energy consumption. The use of the solar insulating materials are the most efficient and cost effective passive methods for reducing the cooling requirements of the buildings. Apart from theoretical studies, no detailed experimental studies were performed in the UAE on energy savings by using solar insulation materials on buildings. Four (3 m × 3 m × 3 m) solar calorimeters were built in RAK, UAE in order to perform an open air outdoor test for energy savings obtained with solar insulating materials. The design is aimed to determine the heat flux reduction and the energy savings achieved with and without different solar insulating materials, mounted at the south wall of solar calorimeters with similar indoor and ambient conditions. Experimental results are discussed to evaluate the thermal performance during high temperature conditions in summer’s period when cooling demand of the building is at its peak and also in winters when there is no cooling demand. The test is from 2012 to 2014. The controlled-temperature experimental study at a set point of 24 °C showed that if the standard building material, i.e. solid concrete, is retrofitted with polyisocyanurate (PIR) and reflective coatings or completely replaced with energy-efficient dry insulation material walls such as exterior insulation finishing system (EIFS), energy savings up to an average of 7.6–25.3% can be achieved. This is due to the reduction of heat flux by an

  18. Thermal highly porous insulation materials made of mineral raw materials

    Science.gov (United States)

    Mestnikov, A.

    2015-01-01

    The main objective of the study is to create insulating foam based on modified mineral binders with rapid hardening. The results of experimental studies of the composition and properties of insulating foam on the basis of rapidly hardening Portland cement (PC) and gypsum binder composite are presented in the article. The article proposes technological methods of production of insulating foamed concrete and its placement to the permanent shuttering wall enclosures in monolithic-frame construction and individual energy-efficient residential buildings, thus reducing foam shrinkage and improving crack-resistance.

  19. Translucent insulating building envelope

    DEFF Research Database (Denmark)

    Rahbek, Jens Eg

    1997-01-01

    A new type of translucent insulating material has been tested. This material is made of Celulose-Acetat and have a honey-comb structure. The material has a high solar transmittance and is highly insulating. The material is relatively cheap to produce. Danish Title: Translucent isolerende klimaskærm....

  20. Design of HTS tri-axial cable in steady-state operation

    International Nuclear Information System (INIS)

    Hu, N.; Toda, M.; Ozcivan, A.N.; Yagai, T.; Tsuda, M.; Hamajima, T.

    2010-01-01

    By the advantage of more compact structure, small leakage field, and low heat loss, tri-axial cable become to be mainstream design in recently HTS practical project. However, the imbalance current problem was also reported by some practice experiments. Since the HTS tri-axial cable is composed of three concentric phases, an unsymmetrical inductance and capacitance distribution which is determined by twist pitches and radii, gives an inherent imbalance in three-phase currents distribution. In our previous research, we proposed a two sections structure design to overcome this limitation. Inductance has been balanced by twist pitch adjusting. In that case, the imbalance ratio of current only can be caused by capacitance distribution which is depending on voltage and line length. In this paper, we evaluate the thickness of insulation, the unsymmetrical capacitance distribution and cable fabrication error. Then we investigate the imbalance ratio due to the capacitance as functions of voltage and length by using Electromagnetic Transients Program (EMTP).

  1. Insulation structure of thermonuclear device

    International Nuclear Information System (INIS)

    Suzuki, Takayuki; Usami, Saburo; Tsukamoto, Hideo; Kikuchi, Mitsuru

    1998-01-01

    The present invention provides an insulating structure of a thermonuclear device, in which insulation materials between toroidal coils are not broken even if superconductive toroidal coils are used. Namely, a tokamak type thermonuclear device of an insulating structure type comprises superconductive toroidal coils for confining plasmas arranged in a circular shape directing the center each at a predetermined angle, and the toroidal coils are insulated from each other. The insulation materials are formed by using a biaxially oriented fiber reinforced plastics. The contact surface of the toroidal coils and the insulating materials are arranged so that they are contact at a woven surface of the fiber reinforced plastics. Either or both of the contact surfaces of the fiber reinforced plastics and the toroidal coils are coated with a high molecular compound having a low friction coefficient. With such a constitution, since the interlayer shearing strength of the biaxially oriented fiber reinforced plastics is about 1/10 of the compression strength, the shearing stress exerted on the insulation material is reduced. Since a static friction coefficient on the contact surface is reduced to provide a structure causing slipping, shearing stress does not exceeds a predetermined limit. As a result, breakage of the insulation materials between the toroidal coils can be prevented. (I.S.)

  2. Effect of dose rate on irreversible changes of electric parameters of power cables for nuclear power plants; Vliyanie moshchnosti dozy na neobratimye izmeneniya ehlektricheskikh paramet rov silovykh kabelej dlya yadernykh ehnergetricheskikh ustanovok

    Energy Technology Data Exchange (ETDEWEB)

    Filatov, N I

    1994-12-31

    Results of an experimental investigation into an irreversible change of insulation resistance, capacitance and tangent of force cable dielectric loss angle under effect of continuous gamma radiation within the certain dose range are presented. In cables with polyethylene insulation dependence of the critical dose on the dose rate in the range investigated is in the for of the function degrees with a degree index of approximately 0.7.

  3. Irradiation and testing of compact ignition tokamak toroidal field coil insulation materials

    International Nuclear Information System (INIS)

    Kanemoto, G.K.; Sherick, M.J.; Sparks, D.C.

    1990-05-01

    This report documents the results of an irradiation and testing program performed on behalf of Martin Marietta Energy Systems, Inc. in support of the Compact Ignition Tokamak Research and Development program. The purpose of the irradiation and testing program was to determine the effects of neutron and gamma irradiation on the mechanical and electrical properties of candidate toroidal field coil insulation materials. Insulation samples were irradiated in the Advanced Test Reactor (ATR) in a large I-hole. The insulation samples were irradiated within a lead shield to reduce exposure to gamma radiation to better approximate the desired ration of neutron to gamma exposure. Two different exposure levels were specified for the insulation samples. To accomplish this, the samples were encapsulated in two separate aluminum capsules; the capsules positioned at the ATR core mid-plane and at the top of the fueled region to take advantage of the axial cosine distribution of the neutron and gamma flux; and by varying the length of irradiation time of the two capsules. Disassembly of the irradiated capsules and testing of the insulation samples were performed at the Test Reactor Area (TRA) Hot Cell Facilities. Testing of the samples included shear compression static, shear compression fatigue, flexure static, and electrical resistance measurements

  4. Prevention of cable fires in nuclear power plants

    International Nuclear Information System (INIS)

    Murota, George; Yajima, Kazuo

    1979-01-01

    Nuclear power generation is indispensable to secure required electric power, therefore double or triple safety measures are necessary to prevent serious accidents absolutely. As for the countermeasures to cable fires, interest grew rapidly with the fire in Browns Ferry Power Station in USA in 1975 as the turning point, because multi-strand grouped cables caused to promote the spread of fire. In Japan, also the fire prevention measures for wires and cables were more strengthened, and the measures for preventing the spread of cable fires with the agent preventing the spread of fires have occupied the important position. When multi-strand cables are ignited by some cause, the fire spreads with very large combustion force along wirings to other rooms and installations, and electric systems are broken down. The harmful corrosive gas generated from the burning coating materials of cables diffuses very quickly. In nuclear power stations, the cables which are very hard to burn are adopted, fire prevention sections are established positively, the fire-resisting capability of fire prevention barriers is reviewed, and fire-resisting and smoke-preventing treatments are applied to the parts where cables penetrate walls, floors or ceilings. The paint and the sealing material which prevent the spread of fires are introduced. (Kako, I.)

  5. Safety distance for preventing hot particle ignition of building insulation materials

    Directory of Open Access Journals (Sweden)

    Jiayun Song

    2014-01-01

    Full Text Available Trajectories of flying hot particles were predicted in this work, and the temperatures during the movement were also calculated. Once the particle temperature decreased to the critical temperature for a hot particle to ignite building insulation materials, which was predicted by hot-spot ignition theory, the distance particle traveled was determined as the minimum safety distance for preventing the ignition of building insulation materials by hot particles. The results showed that for sphere aluminum particles with the same initial velocities and diameters, the horizontal and vertical distances traveled by particles with higher initial temperatures were higher. Smaller particles traveled farther when other conditions were the same. The critical temperature for an aluminum particle to ignite rigid polyurethane foam increased rapidly with the decrease of particle diameter. The horizontal and vertical safety distances were closely related to the initial temperature, diameter and initial velocity of particles. These results could help update the safety provision of firework display.

  6. Review of candidate methods for detecting incipient defects due to aging of installed cables in nuclear power plants

    International Nuclear Information System (INIS)

    Martzloff, F.D.

    1988-01-01

    Several types of test methods have been proposed for detecting incipient defects due to aging in cable insulation systems, none offering certainty of detecting all possible types of defects. Some methods apply direct detection of a defect in the cable; other methods detect changes in electrical or non-electrical parameters from which inference can be drawn on the integrity of the cable. The paper summarizes the first year of a program conducted at the National Bureau of Standards to assess the potential of success for in situ detection of incipient defects by the most promising of these methods

  7. 46 CFR 111.60-6 - Fiber optic cable.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false Fiber optic cable. 111.60-6 Section 111.60-6 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) ELECTRICAL ENGINEERING ELECTRIC SYSTEMS-GENERAL REQUIREMENTS Wiring Materials and Methods § 111.60-6 Fiber optic cable. Each fiber optic cable must— (a) Be...

  8. Cryogenic Properties of Inorganic Insulation Materials for ITER Magnets: A Review

    International Nuclear Information System (INIS)

    Simon, N.J.

    1994-01-01

    Results of a literature search on the cryogenic properties of candidate inorganic insulators for the ITER TF magnets are reported. The materials investigated include: Al 2 O 3 , AlN, MgO, porcelain, SiO 2 , MgAl 2 O 4 , ZrO 2 , and mica. A graphical presentation is given of mechanical, elastic, electrical, and thermal properties between 4 and 300 K. A companion report reviews the low temperature irradiation resistance of these materials

  9. Protection of insulated cables and lines in case of overload

    Energy Technology Data Exchange (ETDEWEB)

    Goltz, M

    1983-01-01

    After DIN 57100 Part 430/VDE 0100 part 430 for the protection of lines and cables was published in June 1981, the discussion flared up again whether this DIN/VDE-regulation is sufficient. Some papers have already been published on the right selection and arrangement of overload protection under normal operational conditions. The aim of this contribution is to explain abnormal operational conditions which are dealt with in DIN 57100 part 430/VDE 0100 part 430 in comments and the annex, and to supply some help for planning and projecting.

  10. Wall insulation system

    Energy Technology Data Exchange (ETDEWEB)

    Kostek, P.T.

    1987-08-11

    In a channel specially designed to fasten semi-rigid mineral fibre insulation to masonry walls, it is known to be constructed from 20 gauge galvanized steel or other suitable material. The channel is designed to have pre-punched holes along its length for fastening of the channel to the drywall screw. The unique feature of the channel is the teeth running along its length which are pressed into the surface of the butted together sections of the insulation providing a strong grip between the two adjacent pieces of insulation. Of prime importance to the success of this system is the recent technological advancements of the mineral fibre itself which allow the teeth of the channel to engage the insulation fully and hold without mechanical support, rather than be repelled or pushed back by the inherent nature of the insulation material. After the insulation is secured to the masonry wall by concrete nail fastening systems, the drywall is screwed to the channel.

  11. Physical processes in high field insulating liquid conduction

    Science.gov (United States)

    Mazarakis, Michael; Kiefer, Mark; Leckbee, Joshua; Anderson, Delmar; Wilkins, Frank; Obregon, Robert

    2017-10-01

    In the power grid transmission where a large amount of energy is transmitted to long distances, High Voltage DC (HVDC) transmission of up to 1MV becomes more attractive since is more efficient than the counterpart AC. However, two of the most difficult problems to solve are the cable connections to the high voltage power sources and their insulation from the ground. The insulating systems are usually composed of transformer oil and solid insulators. The oil behavior under HVDC is similar to that of a weak electrolyte. Its behavior under HVDC is dominated more by conductivity than dielectric constant. Space charge effects in the oil bulk near high voltage electrodes and impeded plastic insulators affect the voltage oil hold-off. We have constructed an experimental facility where we study the oil and plastic insulator behavior in an actual HVDC System. Experimental results will be presented and compared with the present understanding of the physics governing the oil behavior under very high electrical stresses. Sandia National Laboratories managed and operated by National Technology and Engineering Solutions of Sandia, LLC., a wholly owned subsidiary of Honeywell International, Inc., for the U.S. D.O.E., NNSA under contract DE-NA-0003525.

  12. Automated Cable Preparation for Robotized Stator Cable Winding

    Directory of Open Access Journals (Sweden)

    Erik Hultman

    2017-04-01

    Full Text Available A method for robotized cable winding of the Uppsala University Wave Energy Converter generator stator has previously been presented and validated. The purpose of this study is to present and validate further developments to the method: automated stand-alone equipment for the preparation of the winding cables. The cable preparation consists of three parts: feeding the cable from a drum, forming the cable end and cutting the cable. Forming and cutting the cable was previously done manually and only small cable drums could be handled. Therefore the robot cell needed to be stopped frequently. The new equipment was tested in an experimental robot stator cable winding setup. Through the experiments, the equipment was validated to be able to perform fully automated and robust cable preparation. Suggestions are also given on how to further develop the equipment with regards to performance, robustness and quality. Hence, this work represents another important step towards demonstrating completely automated robotized stator cable winding.

  13. Non-destructive qualification tests for ITER cryogenic axial insulating breaks

    International Nuclear Information System (INIS)

    Kosek, Jacek; Lopez, Roberto; Tommasini, Davide; Rodriguez-Mateos, Felix

    2014-01-01

    In the ITER superconducting magnets the dielectric separation between the CICC (Cable-In-Conduit Conductors) and the helium supply pipes is made through the so-called insulating breaks (IB). These devices shall provide the required dielectric insulation at a 30 kV level under different types of stresses and constraints: thermal, mechanical, dielectric and ionizing radiations. As part of the R and D program, the ITER Organization launched contracts with industrial companies aimed at the qualification of the manufacturing techniques. After reviewing the main functional aspects, this paper describes and discusses the protocol established for non-destructive qualification tests of the prototypes

  14. Non-destructive qualification tests for ITER cryogenic axial insulating breaks

    Energy Technology Data Exchange (ETDEWEB)

    Kosek, Jacek [Wroclaw University of Technology, Wybrzeze Wyspianskiego 27, 50-370 Wroclaw, Poland and CERN, Geneva 23,CH-1211 (Switzerland); Lopez, Roberto; Tommasini, Davide [CERN, Geneva 23,CH-1211 (Switzerland); Rodriguez-Mateos, Felix [CERN, Geneva 23,CH-1211, Switzerland and ITER Organization, Route de Vinon sur Verdon, 13115 Saint Paul lez Durance (France)

    2014-01-29

    In the ITER superconducting magnets the dielectric separation between the CICC (Cable-In-Conduit Conductors) and the helium supply pipes is made through the so-called insulating breaks (IB). These devices shall provide the required dielectric insulation at a 30 kV level under different types of stresses and constraints: thermal, mechanical, dielectric and ionizing radiations. As part of the R and D program, the ITER Organization launched contracts with industrial companies aimed at the qualification of the manufacturing techniques. After reviewing the main functional aspects, this paper describes and discusses the protocol established for non-destructive qualification tests of the prototypes.

  15. Voltage-driven magnetization control in topological insulator/magnetic insulator heterostructures

    Directory of Open Access Journals (Sweden)

    Michael E. Flatté

    2017-05-01

    Full Text Available A major barrier to the development of spin-based electronics is the transition from current-driven spin torque, or magnetic-field-driven magnetization reversal, to a more scalable voltage-driven magnetization reversal. To achieve this, multiferroic materials appear attractive, however the effects in current materials occur at very large voltages or at low temperatures. Here the potential of a new class of hybrid multiferroic materials is described, consisting of a topological insulator adjacent to a magnetic insulator, for which an applied electric field reorients the magnetization. As these materials lack conducting states at the chemical potential in their bulk, no dissipative charge currents flow in the bulk. Surface states at the interface, if present, produce effects similar to surface recombination currents in bipolar devices, but can be passivated using magnetic doping. Even without conducting states at the chemical potential, for a topological insulator there is a finite spin Hall conductivity provided by filled bands below the chemical potential. Spin accumulation at the interface with the magnetic insulator provides a torque on the magnetization. Properly timed voltage pulses can thus reorient the magnetic moment with only the flow of charge current required in the leads to establish the voltage. If the topological insulator is sufficiently thick the resulting low capacitance requires little charge current.

  16. Numerical simulation of the insulation material transport to a PWR core under loss of coolant accident conditions

    International Nuclear Information System (INIS)

    Höhne, Thomas; Grahn, Alexander; Kliem, Sören; Rohde, Ulrich; Weiss, Frank-Peter

    2013-01-01

    Highlights: ► Detailed results of a numerical simulation of the insulation material transport to a PWR core are shown. ► The spacer grid is modeled as a strainer which completely retains the insulation material carried by coolant. ► The CFD calculations showed that the fibers at the upper spacer grid plane are not uniformly distributed. ► Furthermore the pressure loss does not exceed a critical limit. ► The PWR core coolablity can be guaranteed all the time during the transient. -- Abstract: In 1992, strainers on the suction side of the ECCS pumps in Barsebäck NPP Unit 2 became partially clogged with mineral wool because after a safety valve opened the steam impinged on thermally insulated equipment and released mineral wool. This event pointed out that strainer clogging is an issue in the course of a loss-of-coolant accident. Modifications of the insulation material, the strainer area and mesh size were carried out in most of the German NPPs. Moreover, back flushing procedures to remove the mineral wool from the strainers and differential pressure measurements were implemented to assure the performance of emergency core cooling during the containment sump recirculation mode. Nevertheless, it cannot be completely ruled out, that a limited amount of small fractions of the insulation material is transported into the RPV. During a postulated cold leg LOCA with hot leg ECC injection, the fibers enter the upper plenum and can accumulate at the fuel element spacer grids, preferably at the uppermost grid level. This effect might affect the ECC flow into the core and could result in degradation of core cooling. It was the aim of the numerical simulations presented to study where and how many mineral wool fibers are deposited at the upper spacer grid. The 3D, time dependent, multi-phase flow problem was modeled applying the CFD code ANSYS CFX. The CFD calculation does not yet include steam production in the core and also does not include re-suspension of the

  17. Cabling design of booster and storage ring construction progress of TPS

    International Nuclear Information System (INIS)

    Wong, Y.-S.; Liu, K.-B.; Liu, C.-Y.; Wang, B.-S.

    2017-01-01

    The 2012 Taiwan Photon Source (TPS) cable construction project started after 10 months to complete the cable laying and installation of power supply. The circumference of the booster ring (BR) is 496.8 m, whereas that of the storage ring (SR) is 518.4 m. Beam current is set to 500 mA at 3.3 GeV. The paper on grounding systems discusses the design of the ground wire (< 0.2 Ω) with low impedance, power supply of the accelerator and cabling tray. The flow and size of the ground current are carefully evaluated to avoid grounded current from flowing everywhere, which causes interference problems. In the design of the TPS, special shielding will be established to isolate the effects of electromagnetic interference on the magnet and ground current. Booster ring dipoles are connected by a series of 54-magnet bending dipole; the cable size of its stranded wire measures 250 mm"2, with a total length of 5000 m. Booster ring and storage ring quadrupoles have 150 magnets; the cable size of their stranded wire is 250 mm"2, with a total length of 17000 m. Storage ring dipole consists of 48 magnets; the cable size of its stranded wire is 325 mm"2, with a total length of 6000 m. This study discusses the power supply cabling design of the storage ring and booster ring construction progress of TPS. The sections of this paper are divided into discussions of the construction of the control and instrument area, cabling layout of booster ring and storage ring, as well as the installation and commission machine. This study also discusses the use of a high-impedance meter to determine the effect of cabling insulation and TPS power supply machine on energy transfer to ensure the use of safe and correct magnet.

  18. Investigation of cryogenic irradiation influence on mechanical and physical properties of ITER magnetic system insulation materials

    International Nuclear Information System (INIS)

    Kozlov, A.V.; Scherbacov, E.N.; Dudchenko, N.A.; Shihalev, V.S.; Bedin, V.V.; Paltusov, N.A.; Korsunskiy, V.E.

    1998-01-01

    A set of methods of cryogenic irradiation influence test on mechanical and physical properties of insulation of ITER magnetic system are presented in this paper. Investigations are carried out without intermediate warming up of samples. A Russian insulating composite material was irradiated in the IVV-2M reactor. The ratio of energy absorbed by insulation materials from neutron irradiation to that from gamma irradiation can be varied from ∝(25:75)% to ∝(50:50)% in the reactor. The test results on the thermal expansion, thermal conductivity and gas evolution of the above material are presented. It was shown, that cryogenic irradiation up to the fluence ∝2 x 10 22 n/m 2 (E ≥ 0.1 MeV) leads to 0.27% linear size changes along layers of fiber-glass, the thermal conductivity coefficient is decreased on 15% at 100 k in perpendicular direction to fiber-glass plane, and thermal coefficient of linear expansion (TCLE) has anomalous temperature dependence. (orig.)

  19. Environmental assessment of submarine power cables

    Energy Technology Data Exchange (ETDEWEB)

    Isus, Daniel; Martinez, Juan D. [Grupo General Cable Sistemas, S.A., 08560-Manlleu, Barcelona (Spain); Arteche, Amaya; Del Rio, Carmen; Madina, Virginia [Tecnalia Research and Innovation, 20009 San Sebastian (Spain)

    2011-03-15

    Extensive analyses conducted by the European Community revealed that offshore wind energy have relatively benign effects on the marine environment by comparison to other forms of electric power generation [1]. However, the materials employed in offshore wind power farms suffer major changes to be confined to the marine environment at extreme conditions: saline medium, hydrostatic pressure... which can produce an important corrosion effect. This phenomenon can affect on the one hand, to the material from the structural viewpoint and on the other hand, to the marine environment. In this sense, to better understand the environmental impacts of generating electricity from offshore wind energy, this study evaluated the life cycle assessment for some new designs of submarine power cables developed by General Cable. To achieve this goal, three approaches have been carried out: leaching tests, eco-toxicity tests and Life Cycle Assessment (LCA) methodologies. All of them are aimed to obtaining quantitative data for environmental assessment of selected submarine cables. LCA is a method used to assess environmental aspects and potential impacts of a product or activity. LCA does not include financial and social factors, which means that the results of an LCA cannot exclusively form the basis for assessment of a product's sustainability. Leaching tests results allowed to conclude that pH of seawater did not significantly changed by the presence of submarine three-core cables. Although, it was slightly higher in case of broken cable, pH values were nearly equals. Concerning to the heavy metals which could migrate to the aquatic medium, there were significant differences in both scenarios. The leaching of zinc is the major environmental concern during undersea operation of undamaged cables whereas the fully sectioned three-core cable produced the migration of significant quantities of copper and iron apart from the zinc migrated from the galvanized steel. Thus, the tar

  20. Environmental assessment of submarine power cables

    International Nuclear Information System (INIS)

    Isus, Daniel; Martinez, Juan D.; Arteche, Amaya; Del Rio, Carmen; Madina, Virginia

    2011-03-01

    Extensive analyses conducted by the European Community revealed that offshore wind energy have relatively benign effects on the marine environment by comparison to other forms of electric power generation [1]. However, the materials employed in offshore wind power farms suffer major changes to be confined to the marine environment at extreme conditions: saline medium, hydrostatic pressure... which can produce an important corrosion effect. This phenomenon can affect on the one hand, to the material from the structural viewpoint and on the other hand, to the marine environment. In this sense, to better understand the environmental impacts of generating electricity from offshore wind energy, this study evaluated the life cycle assessment for some new designs of submarine power cables developed by General Cable. To achieve this goal, three approaches have been carried out: leaching tests, eco-toxicity tests and Life Cycle Assessment (LCA) methodologies. All of them are aimed to obtaining quantitative data for environmental assessment of selected submarine cables. LCA is a method used to assess environmental aspects and potential impacts of a product or activity. LCA does not include financial and social factors, which means that the results of an LCA cannot exclusively form the basis for assessment of a product's sustainability. Leaching tests results allowed to conclude that pH of seawater did not significantly changed by the presence of submarine three-core cables. Although, it was slightly higher in case of broken cable, pH values were nearly equals. Concerning to the heavy metals which could migrate to the aquatic medium, there were significant differences in both scenarios. The leaching of zinc is the major environmental concern during undersea operation of undamaged cables whereas the fully sectioned three-core cable produced the migration of significant quantities of copper and iron apart from the zinc migrated from the galvanized steel. Thus, the tar

  1. Device Performance of the Mott InsulatorDevice Performance of the Mott Insulator LaVO3 as a Photovoltaic Material

    KAUST Repository

    Wang, Lingfei

    2015-06-22

    Searching for solar-absorbing materials containing earth-abundant elements with chemical stability is of critical importance for advancing photovoltaic technologies. Mott insulators have been theoretically proposed as potential photovoltaic materials. In this paper, we evaluate their performance in solar cells by exploring the photovoltaic properties of Mott insulator LaVO3 (LVO). LVO films show an indirect band gap of 1.08 eV as well as strong light absorption over a wide wavelength range in the solar spectrum. First-principles calculations on the band structure of LVO further reveal that the d−d transitions within the upper and lower Mott-Hubbard bands and p−d transitions between the O 2p and V 3d band contribute to the absorption in visible and ultraviolet ranges, respectively. Transport measurements indicate strong carrier trapping and the formation of polarons in LVO. To utilize the strong light absorption of LVO and to overcome its poor carrier transport, we incorporate it as a light absorber in solar cells in conjunction with carrier transporters and evaluate its device performance. Our complementary experimental and theoretical results on such prototypical solar cells made of Mott-Hubbard transition-metal oxides pave the road for developing light-absorbing materials and photovoltaic devices based on strongly correlated electrons.

  2. Cryogenic Properties of Inorganic Insulation Materials for ITER Magnets: A Review

    Energy Technology Data Exchange (ETDEWEB)

    Simon, N.J.

    1994-12-01

    Results of a literature search on the cryogenic properties of candidate inorganic insulators for the ITER TF magnets are reported. The materials investigated include: Al{sub 2}O{sub 3}, AlN, MgO, porcelain, SiO{sub 2}, MgAl{sub 2}O{sub 4}, ZrO{sub 2}, and mica. A graphical presentation is given of mechanical, elastic, electrical, and thermal properties between 4 and 300 K. A companion report reviews the low temperature irradiation resistance of these materials.

  3. Aerogels: transparent and super-insulating materials; Les aerogels: isolants transparent-super isolants

    Energy Technology Data Exchange (ETDEWEB)

    Melka, S.; Rigacci, A.; Achard, P.; Bezian, J.J. [Ecole des Mines de Paris, 06 - Sophia-Antipolis (France); Sallee, H.; Chevalier, B. [Centre des Sciences et Techniques du Batiment, 38 - Saint-Martin-d`Heres (France)

    1996-12-31

    Recent studies have demonstrated the super-insulating properties of silica aerogel in its monolithic or finely divided state. In its monolithic state, this material conciliates excellent thermal insulation performances, a good transmission of visible light and interesting acoustic properties. Also its amazing structural characteristics (lightness, high global porosity, small diameter of pores) are particularly interesting for its use in double glazing windows as transparent insulating spacer. The aim of the work carried out by the Energetic Centre of the Ecole des Mines of Paris is to understand the thermal transfer phenomena in all forms of silica aerogel. In this paper, the main steps of the synthesis process of monolithic silica aerogel is presented with the thermal conductivities obtained. Then, a model is built to describe the thermal transfer mechanisms in finely divided aerogel beds. Finally, the hot wire thermal characterization method is presented and the results obtained on silica aerogels are discussed. (J.S.) 16 refs.

  4. Quantitative data on the fire behavior of combustible materials found in nuclear power plants: A literature review

    International Nuclear Information System (INIS)

    Nowlen, S.P.

    1987-02-01

    This report presents the findings of a task in which currently available fire research literature was reviewed for quantitative data on the burning characteristics of combustible materials that are found in nuclear power plants. The materials considered for which quantitative data were available include cable insulation materials, flammable liquids, furniture, trash and general refuse, and wood and wood products. A total of 90 figures and tables, taken primarily from the referenced works, which summarize the available quantitative fire characterization information for these materials is presented

  5. Simple Program to Investigate Hysteresis Damping Effect of Cross-Ties on Cables Vibration of Cable-Stayed Bridges

    Directory of Open Access Journals (Sweden)

    Panagis G. Papadopoulos

    2012-01-01

    Full Text Available A short computer program, fully documented, is presented, for the step-by-step dynamic analysis of isolated cables or couples of parallel cables of a cable-stayed bridge, connected to each other and possibly with the deck of the bridge, by very thin pretensioned wires (cross-ties and subjected to variation of their axial forces due to traffic or to successive pulses of a wind drag force. A simplified SDOF model, approximating the fundamental vibration mode, is adopted for every individual cable. The geometric nonlinearity of the cables is taken into account by their geometric stiffness, whereas the material nonlinearities of the cross-ties include compressive loosening, tensile yielding, and hysteresis stress-strain loops. Seven numerical experiments are performed. Based on them, it is observed that if two interconnected parallel cables have different dynamic characteristics, for example different lengths, thus different masses, weights, and geometric stiffnesses, too, or if one of them has a small additional mass, then a single pretensioned very thin wire, connecting them to each other and possibly with the deck of the bridge, proves effective in suppressing, by its hysteresis damping, the vibrations of the cables.

  6. Dynamic space charge behaviour in polymeric DC cables

    DEFF Research Database (Denmark)

    Rasmussen, Claus Nygaard; Holbøll, Joachim; Henriksen, Mogens

    2002-01-01

    The use of extruded insulation for DC cables involves a risk of local electric field enhancement, caused by a space charge build-up within the dielectric. In this work, the theory of charge generation and transport in polymers is applied in a numerical computer model in order to predict...... the formation and transport of space charges in a polymeric dielectric. The model incorporates the processes of field assisted electron-hole pair generation from impurity atoms, trapping and charge injection at the electrodes. Its aim has been to study the field- and temperature dependent dynamic behaviour...

  7. Development of halogen-free cables for nuclear power plants

    International Nuclear Information System (INIS)

    Yamamoto, Mitsuo; Ito, Kazumi; Yaji, Takeo; Yoshida, Shin; Sakurai, Takako; Matsushita, Shigetoshi.

    1990-01-01

    On the occasion where serious fire accidents were experienced in the past, the need for making flame-retardant wire and cable incombustible took place and has since been generalizing. Various sorts of flame-retardant cables have already been developed and been actually used. From the viewpoint of avoiding the interference with the evacuation and fire-fighting activity in case of fire or the secondary accidents such as corrosion of the distributing panel, etc., the demand for non-halogen flame-retardant cable has rapidly been increasing in recent years in some fields of general industries, because this specific cable would generate the least amount of toxic smoke or corrosive gas even when it should burn. Similar demand has been increasing also for the cable used for nuclear power plants. In this field, earnest desire has been made for the development of non-halogen flame-retardant cable having specific environmental resistance specially required at nuclear power plants in addition to the properties and capacities required in general industries. The authors have continued examinations on the anti-environmental properties of the materials for cable such as long heat resistance, radiation resistance, steam resistance and succeeded in completing various sorts of non-halogen flame-retardant cable for nuclear power plants. In this report, we will introduce various features of the cable we have developed this time as well as the long-term reliability of non-halogen flame-retardant materials. (author)

  8. Lessons learned from the development and manufacture of ceramic reusable surface insulation materials for the space shuttle orbiters

    Science.gov (United States)

    Banas, R. P.; Elgin, D. R.; Cordia, E. R.; Nickel, K. N.; Gzowski, E. R.; Aguiler, L.

    1983-01-01

    Three ceramic, reusable surface insulation materials and two borosilicate glass coatings were used in the fabrication of tiles for the Space Shuttle orbiters. Approximately 77,000 tiles were made from these materials for the first three orbiters, Columbia, Challenger, and Discovery. Lessons learned in the development, scale up to production and manufacturing phases of these materials will benefit future production of ceramic reusable surface insulation materials. Processing of raw materials into tile blanks and coating slurries; programming and machining of tiles using numerical controlled milling machines; preparing and spraying tiles with the two coatings; and controlling material shrinkage during the high temperature (2100-2275 F) coating glazing cycles are among the topics discussed.

  9. Band inversion mechanism in topological insulators: A guideline for materials design

    KAUST Repository

    Zhu, Zhiyong; Cheng, Yingchun; Schwingenschlö gl, Udo

    2012-01-01

    Alteration of the topological order by band inversion is a key ingredient of a topologically nontrivial material. Using first-principles calculations for HgTe, PtScBi, and Bi2Se3, we argue that it is not accurate to ascribe the band inversion to the spin-orbit coupling. Instead, scalar relativistic effects and/or lattice distortions are found to be essential. Therefore, the search for topologically nontrivial materials should focus on band shifts due to these mechanisms rather than spin-orbit coupling. We propose an effective scheme to search for new topological insulators.

  10. Band inversion mechanism in topological insulators: A guideline for materials design

    KAUST Repository

    Zhu, Zhiyong

    2012-06-01

    Alteration of the topological order by band inversion is a key ingredient of a topologically nontrivial material. Using first-principles calculations for HgTe, PtScBi, and Bi2Se3, we argue that it is not accurate to ascribe the band inversion to the spin-orbit coupling. Instead, scalar relativistic effects and/or lattice distortions are found to be essential. Therefore, the search for topologically nontrivial materials should focus on band shifts due to these mechanisms rather than spin-orbit coupling. We propose an effective scheme to search for new topological insulators.

  11. Insulation systems of the building construtions

    Directory of Open Access Journals (Sweden)

    Rumiantcev Boris

    2016-01-01

    Full Text Available Constructions of the exterior insulation and decoration combines materials of different functionality and constructive solutions allows to these materials to demonstrate their efficiency to the great extent. Fire safety of buildings is mandatory requirement for building systems. Some insulating material may belong to the group of combustible, but their use in structures so as to minimize the risk of fire. On the other hand, there are special designs, in which non-flammable insulation acts as a flame retardant barrier. In the article carried systematization of construction systems used in the flat and pitched roof during the insulation and wall covering and facades. Taking into account the experience of leading firms were considered the application features of using exterior finish systems: construction solutions, requirements for materials and recommendations about the installation these systems.The article deals with the construction ventilated roofing system of two types: flat roof and pitched roof seam. In the first case, the ventilation system is created using milled insulation boards in the second - by a ventilated gap. In both cases the natural convection of air in the air cavities. Ensuring operational stability insulation is laid on the stages of production of heat-insulating materials. It is important: firstly responsible execution of all process operations associated with providing regulatory properties of materials and secondly, the performance of additional operations associated with the produc-tion of materials, working in a specific design. An example of a material whose properties can modify for a particular application, are milled mineral wool (with air channels for systems of ventilated flat roof.

  12. The human impact on natural rock reserves using basalt, anorthosite, and carbonates as raw materials in insulation products

    DEFF Research Database (Denmark)

    Dahl, Tais Wittchen; Clausen, Anders U.; Hansen, Peter B.

    2011-01-01

    lithosphere or subducted with oceanic crust and recycled through the mantle by plate tectonics. Insulation products have a chemical composition similar to average crustal rocks and participate in the natural rock cycle. However, these products need not accumulate in nature, inasmuch as old insulation......Typical crustal rocks such as basalt, limestone, and anorthosite are used in stone wool insulation products. The raw materials for stone wool production are not specific to any rare mineral source but depend upon the mixture of materials having the correct chemical composition, exemplified by 40 wt......% basalt, 20 wt% anorthosite, and 40 wt% cement-bonded renewable materials. This study provides an overview of the natural cycle of these resources, including their abundances in nature, and sets the consumption by the stone wool industry and other human activities in perspective. Basalt, anorthosite...

  13. Electrical insulating liquid: A review

    Directory of Open Access Journals (Sweden)

    Deba Kumar Mahanta

    2017-08-01

    Full Text Available Insulating liquid plays an important role for the life span of the transformer. Petroleum-based mineral oil has become dominant insulating liquid of transformer for more than a century for its excellent dielectric and cooling properties. However, the usage of petroleum-based mineral oil, derived from a nonrenewable energy source, has affected the environment for its nonbiodegradability property. Therefore, researchers direct their attention to renewable and biodegradable alternatives. Palm fatty acid ester, coconut oil, sunflower oil, etc. are considered as alternatives to replace mineral oil as transformer insulation liquid. This paper gives an extensive review of different liquid insulating materials used in a transformer. Characterization of different liquids as an insulating material has been discussed. An attempt has been made to classify different insulating liquids-based on different properties.

  14. Adsorption on insulator materials enhanced by D implantation

    International Nuclear Information System (INIS)

    Ibarra, A.; Climent-Font, A.; Munoz-Martin, A.

    2005-01-01

    Many insulator materials used in ITER are exposed to a gas phase composed of D, T and a plasma with hydrocarbons, Fe and other particles combined with the presence of an intense neutron and gamma radiation field. Some of these materials (Al 2 O 3 and SiO 2 ) are implanted at room temperature with low energy D and H ions in order to simulate some of the DT gas effects. The implantation is characterized using optical absorption and elastic recoil detection analysis (ERDA) techniques. It is observed that ion implantation as well as electron or gamma irradiation increases the surface scattering and the concentration of C and H adsorbed at the surface, suggesting that a radiation-induced surface degradation process is taking place and an increase of the surface adsorption capability. The effect is higher for higher dose implantation and for lower energy

  15. Numerical Simulation of Electro-Mechanical Impedance Response in Cable-Anchor Connection Interface

    International Nuclear Information System (INIS)

    Nguyen, Khac Duy; Kim, Jeong Tae

    2011-01-01

    In this study, a finite element(FE) analysis on electro-mechanical impedance response of cable-anchor connection interface under various anchor force is presented. In order to achieve the objective, the following approaches are implemented. Firstly, an interface washer coupled with piezoelectric(PZT) material is designed for monitoring cable-force loss. The interface washer is a small aluminum plate on which a PZT patch is surface-bonded. Cable-force loss could be monitored by installing the interface washer between the anchor plate and the anchorage of cable-anchor connection and examining the changes of impedance of the interface washer. Secondly, a FE model for cable-anchor connection is established to examine the effect of cable-force on impedance response of interface washer. Also, the effects of geometrical and material properties of the interface washer on impedance responses under various cable-forces are investigated. Finally, validation of the FE analysis is experimentally evaluated by a lab-scale cable-anchor connection

  16. Forming Refractory Insulation On Copper Wire

    Science.gov (United States)

    Setlock, J.; Roberts, G.

    1995-01-01

    Alternative insulating process forms flexible coat of uncured refractory insulating material on copper wire. Coated wire formed into coil or other complex shape. Wire-coating apparatus forms "green" coat on copper wire. After wire coiled, heating converts "green" coat to refractory electrical insulator. When cured to final brittle form, insulating material withstands temperatures above melting temperature of wire. Process used to make coils for motors, solenoids, and other electrical devices to be operated at high temperatures.

  17. Studies on the flame and radiation resistant modification of wires and cables for nuclear power generation plants

    International Nuclear Information System (INIS)

    Hagiwara, Miyuki; Morita, Yosuke; Udagawa, Akira; Oda, Eisuke; Fujimura, Shunichi.

    1982-08-01

    For the use in the light-water nuclear power generation plants, wires and cables are required to keep high flame retardancy and superior resistivity against heat and radiation throughout the whole period of service. They are expected, further, to fulfill their functions even under LOCA conditions. The present work aimed to provide new technology to give flame and radiation resistancy to insulating materials for the cables which are used under the above requirements. For the improvement of flame retardancy and the elongation of life time, polymerizable flame retardants were examined their applicability to ethylene-propylene-diene rubber. Various polymerizable flame retardants were first synthesized, and their performance was analyzed, especially, as to the relationship between molecular structure and their effectiveness. As a guiding principle for developing of a high performance flame and radiation resistant reagent, it was suggested that the back born of the reagent molecule should be constructed by carbon-carbon bond including fused aromatic rings and groups which can undergo polymerization by radical initiators. After careful consideration and detailed experimental work, condensed bromoacenaphthylene (con-BACN) was shown to have an effectiveness enough for the present purpose. Its satisfactory performance was also shown by making cables of a practical size using con-BACN, and by carrying out various performance tests based substantially on IEEE standards. (author)

  18. Radiation tests at cryogenic temperature on selected organic materials for LHC

    International Nuclear Information System (INIS)

    Humer, K.; Weber, H.W.; Szeless, B.; Tavlet, M.

    1997-01-01

    Future multi-TeV particle accelerators like the CERN Large Hadron Collider (LHC) will use superconducting magnets in which organic materials will be exposed to high radiation levels at temperatures as low as 2 K. A representative selection of organic materials comprising insulating films, cable insulations, epoxy resins and composites were exposed to neutron and gamma radiation of a nuclear reactor. Depending on the type of materials, the integrated radiation doses varied between 180 kGy and 155 MGy. During irradiation, the samples were kept close to the boiling temperature of liquid nitrogen, i.e. at 80 K, and thereafter stored in liquid nitrogen and transferred at the same temperature into the testing device for measurement of tensile and flexural strength. Tests were carried out on the same materials at similar dose rates at room temperature, and the results are compared with the ones obtained at cryogenic temperature. They show that within the selected dose range, a number of organic materials are suitable for use in radiation fields of the LHC at cryogenic temperature

  19. Fault Management of a Cold Dielectric HTS Power Transmission Cable

    International Nuclear Information System (INIS)

    Maguire, J; Allais, A; Yuan, J; Schmidt, F; Hamber, F; Welsh, Tom

    2006-01-01

    High temperature superconductor (HTS) power transmission cables offer significant advantages in power density over conventional copper-based cables. As with conventional cables, HTS cables must be safe and reliable when abnormal conditions, such as local and through faults, occur in the power grid. Due to the unique characteristics of HTS power cables, the fault management of an HTS cable is different from that of a conventional cable. Issues, such as nitrogen bubble formation within lapped dielectric material, need to be addressed. This paper reviews the efforts that have been performed to study the fault conditions of a cold dielectric HTS power cable. As a result of the efforts, a fault management scheme has been developed, which provides both local and through faults system protection. Details of the fault management scheme with examples are presented

  20. Thermal insulation

    International Nuclear Information System (INIS)

    Durston, J.G.; Birch, W.; Facer, R.I.; Stuart, R.A.

    1977-01-01

    Reference is made to liquid metal cooled nuclear reactors. In the arrangement described the reactor vessel is clad with thermal insulation comprising a layer of insulating blocks spaced from the wall and from each other; each block is rigidly secured to the wall, and the interspaces are substantially closed against convectional flow of liquid by resilient closure members. A membrane covering is provided for the layer of blocks, with venting means to allow liquid from the reactor vessel to penetrate between the covering and the layer of blocks. The membrane covering may comprise a stainless steel sheet ribbed in orthogonal pattern to give flexibility for the accommodation of thermal strain. The insulating blocks may be comprised of stainless steel or cellular or porous material and may be hollow shells containing ceramic material or gas fillings. (U.K.)

  1. Ablation characteristics and reaction mechanism of insulation materials under slag deposition condition

    Science.gov (United States)

    Guan, Yiwen; Li, Jiang; Liu, Yang

    2017-07-01

    Current understanding of the physical and chemical processes involved in the ablation of insulation materials by highly aluminized solid propellants is limited. The study on the heat transfer and ablation principle of ethylene propylene diene monomer (EPDM) materials under slag deposition condition is essential for future design or modification of large solid rocket motors (SRMs) for launch application. In this paper, the alumina liquid flow pattern and the deposition principle in full-scale SRM engines are discussed. The interaction mechanism between the alumina droplets and the wall are analyzed. Then, an experimental method was developed to simulate the insulation material ablation under slag deposition condition. Experimental study was conducted based on a laboratory-scale device. Meanwhile, from the analysis of the cross-sectional morphology and chemical composition of the charring layer after ablation, the reaction mechanism of the charring layer under deposition condition was discussed, and the main reaction equation was derived. The numerical simulation and experimental results show the following. (i) The alumina droplet flow in the deposition section of the laboratory-scale device is similar to that of a full-scale SRM. (ii) The charring layer of the EPDM insulator displays a porous tight/loose structure under high-temperature slag deposition condition. (iii) A seven-step carbothermal reduction in the alumina is derived and established under high-pressure and high-temperature environment in the SRM combustion chamber. (iv) The analysis using thermodynamic software indicates that the reaction of the alumina and charring layer initially forms Al4C3 during the operation. Then, Al element and Al2OC compound are subsequently produced with the reduction in the release of gas CO as well with continuous environmental heating.

  2. Thermal conductivity: recent developments on insulating and new materials; La conductivite thermique: developpements recents sur les isolants et les materiaux nouveaux

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1996-12-31

    This workshop organized by the thermo-kinetics section of the French society of thermal engineers deals with recent developments concerning insulating, dielectric and composite materials. The seven papers presented during this workshop concern the methods and results of thermal conductivity measurements performed in these materials and the possible applications of these materials in aerospace industry (carbon foams, ceramic-based composite materials), civil engineering (glazing materials, aerogels), power electronics (dielectric thin films, ceramics), and in other industries (heat resistant and thermal insulating materials). (J.S.)

  3. Field experiments on the use of phase changing materials, insulation materials and passive solar radiation in the built environment

    NARCIS (Netherlands)

    Entrop, Alexis Gerardus; Brouwers, Jos; Reinders, Angelina H.M.E.; McCarthy, J.; Foliente, G.

    2008-01-01

    This paper describes the development of an experimental research facility to assess the effectiveness of Phase Change Materials (PCM), that can be used for passive solar heating. Four test boxes are constructed representing the conventional and future Dutch building practices regarding insulation

  4. Magnetization Losses of Roebel Cable Samples with 2G YBCO Coated Conductor Strands

    CERN Document Server

    Yang, Y.; Falorio, I.; Young, E.A.; Kario, A.; Goldacker, W.; Dhallé, M. M. J.; van Nugteren, J.; Kirby, G.; Bottura, L.; Ballarino, A.

    2016-01-01

    Roebel cable with 2G YBCO strands is one of the promising HTS solutions of fully transposed high current conductors for high field accelerator magnets. Following the considerable research effort on the manufacturing of Roebel cables in recent years, sample conductors are now available in useful lengths with reproducible performances to allow detailed characterizations beyond the standard critical current measurements. The ac loss and strands coupling are of significant interest for the field quality of the accelerator magnets. We report a set of systematic ac loss measurements on two different Roebel cable samples prepared for the EuCARD2 collaboration. The measurements were performed over a wide range of temperature between 5 K and 90 K and the results were analyzed in the context of strands architecture and coupling. The results show that the transposed bundles are partially decoupled and the strands in transposition sections behave as an isolated single tape if the strands are insulated.

  5. Development of Halogen-free flame-retardant cable for nuclear power plant

    International Nuclear Information System (INIS)

    Ishii, Nobuhisa; Morii, Akira; Fujimura, Shunichi

    1992-01-01

    Conventional flame-retardant cables release a large volume of corrosive and toxic gases as well as smoke while combusted. Cables covered with halogen-free flame-retardant material, containing no halogen in it, have been developed to reduce generation of such gases and smoke, and have already been used in telecommunication service, subway and shipboard applications. However, for cables for nuclear power plant, covering materials should also have radiation resistance and other properties, including long-term physical stability. We have developed halogen-free flame-retardant cables for BWR nuclear power plant with sufficient flame retardancy radiation resistance and environmental resistance including steam-exposure resistance all of which are in accordance with Japanese specifications for BWR nuclear cables and have such characteristics as low corrosiveness, low toxicity and low smoke emission. (author)

  6. Development of halogen-free flame-retardant cable for nuclear power plant

    International Nuclear Information System (INIS)

    Ishii, Nobuhisa; Morii, Akira; Fujimura, Shunichi

    1991-01-01

    Conventional flame-retardant cables release a large amount of corrosive and toxic gases and also smoke during combustion on fire. Cables covered with halogen-free flame-retardant material, containing no halogen in it, have been developed to reduce generation of such gases and smoke, and already used in telecommunication plant, subway and shipboard applications. In the case of nuclear power plant application, cable covering materials should also have radiation resistance and other properties including long-term physical stability. We have developed halogen-free flame-retardant cables for nuclear power plant with sufficient flame retardancy, radiation resistance, and environmental resistance including steam-exposure resistance, all of which are in accordance with Japanese specifications for nuclear cables, and with characteristics as low corrosiveness, low toxicity, and low smoke evolution. (author)

  7. Vacuum-insulated catalytic converter

    Science.gov (United States)

    Benson, David K.

    2001-01-01

    A catalytic converter has an inner canister that contains catalyst-coated substrates and an outer canister that encloses an annular, variable vacuum insulation chamber surrounding the inner canister. An annular tank containing phase-change material for heat storage and release is positioned in the variable vacuum insulation chamber a distance spaced part from the inner canister. A reversible hydrogen getter in the variable vacuum insulation chamber, preferably on a surface of the heat storage tank, releases hydrogen into the variable vacuum insulation chamber to conduct heat when the phase-change material is hot and absorbs the hydrogen to limit heat transfer to radiation when the phase-change material is cool. A porous zeolite trap in the inner canister absorbs and retains hydrocarbons from the exhaust gases when the catalyst-coated substrates and zeolite trap are cold and releases the hydrocarbons for reaction on the catalyst-coated substrate when the zeolite trap and catalyst-coated substrate get hot.

  8. EVALUATION OF THERMAL INSULATION FOR THREE DIFFERENT MATERIALS USED IN CONSTRUCTION AND COMPLETION OF EXTERNAL WALLS

    Directory of Open Access Journals (Sweden)

    Marcio Carlos Navroski

    2010-05-01

    Full Text Available Summers increasingly hot are bringing large thermal problems within homes and businesses, leading to increased demand for installation of air conditioners and the consequent high energy consumption. Constructions with thermal insulation on its external walls thatcould reduce energy use or even supply the use of such equipment. Due to these factors the present study was to evaluate the insulation in three boxes built with different materials, one made of wooden boards with plain walls, and two built with plywood, wall insulation andinterior walls filled with rice husk and Styrofoam®. The boxes were built after placed in drying oven at 40 °C, then noted the temperature inside the same interval every five minutes using a digital thermometer. The box with inner Styrofoam® showed the lowest variation among the three evaluated, followed by the box of rice husk. These two materials also showed good thermal initial, unlike the box built only with wood, which showed a large interiorheating, lay in a drying oven.

  9. Cardboard Based Packaging Materials as Renewable Thermal Insulation of Buildings: Thermal and Life Cycle Performance

    OpenAIRE

    Čekon, Miroslav; Struhala, Karel; Slávik, Richard

    2017-01-01

    Cardboard based packaging components represent a material with a significant potential of renewable exploitation in buildings. This study presents the results of thermal and environmental analysis of existing packaging materials compared with standard conventional thermal insulations. Experimental measurements were performed to identify the thermal performance of studied cardboard packaging materials. Real-size samples were experimentally tested in laboratory measurements. The thermal resi...

  10. Analysis of copper contamination in transformer insulating material with nanosecond- and femtosecond-laser-induced breakdown spectroscopy

    Science.gov (United States)

    Aparna, N.; Vasa, N. J.; Sarathi, R.

    2018-06-01

    This work examines the oil-impregnated pressboard insulation of high-voltage power transformers, for the determination of copper contamination. Nanosecond- and femtosecond-laser-induced breakdown spectroscopy revealed atomic copper lines and molecular copper monoxide bands due to copper sulphide diffusion. X-ray diffraction studies also indicated the presence of CuO emission. Elemental and molecular mapping compared transformer insulating material ageing in different media—air, N2, He and vacuum.

  11. An experimental study on thermal properties of composite insulation

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Gyoung-Seok [Building and Urban Research Department, Korea Institute of Construction Technology, 2311 Daehwa-Dong, Ilsanseo-Gu, Goyang-Si, Gyeonggi-Do 411-712 (Korea); College of Architecture, Hanyang University, 17, Hangdang-Dong, Sungdong-Gu, Seoul 133-791 (Korea); Kang, Jae-Sik; Jeong, Young-Sun; Lee, Seung-Eon [Building and Urban Research Department, Korea Institute of Construction Technology, 2311 Daehwa-Dong, Ilsanseo-Gu, Goyang-Si, Gyeonggi-Do 411-712 (Korea); Sohn, Jang-Yeul [College of Architecture, Hanyang University, 17, Hangdang-Dong, Sungdong-Gu, Seoul 133-791 (Korea)

    2007-04-01

    In accordance with the insulation standards reinforced since 2001 and the compulsory standards on floor impact sound insulation that have been enforced since 2004, insulation materials for actual buildings have been converted to composite materials and new insulation materials have been released in the market. However, Korea is lagging behind the world in fundamental experimental studies and resources. In case of some composite insulation materials, there also have been problems of distorted performance occurring as a result of tests being conducted without having verification and evaluation on the accuracy and inaccuracy of such tests. Therefore, this study grasped the thermal properties of composite insulation materials using thermal conductivity test equipment by heat flux method, and performed quantitative evaluation on the measurement precision and uncertainty of composite materials. (author)

  12. Thermal-Insulation Properties of Multilayer Textile Packages

    Directory of Open Access Journals (Sweden)

    Matusiak Małgorzata

    2014-12-01

    Full Text Available Thermal-insulation properties of textile materials play a significant role in material engineering of protective clothing. Thermal-insulation properties are very important from the point of view of thermal comfort of the clothing user as well as the protective efficiency against low or high temperature. Thermal protective clothing usually is a multilayer construction. Its thermal insulation is a resultant of a number of layers and their order, as well as the thermalinsulation properties of a single textile material creating particular layers. The aim of the presented work was to investigate the relationships between the thermal-insulation properties of single materials and multilayer textile packages composed of these materials. Measurement of the thermal-insulation properties of single and multilayer textile materials has been performed with the Alambeta. The following properties have been investigated: thermal conductivity, resistance and absorptivity. Investigated textile packages were composed of two, three and four layers made of woven and knitted fabrics, as well as nonwovens. On the basis of the obtained results an analysis has been carried out in order to assess the dependency of the resultant values of the thermal-insulation properties of multilayer packages on the appropriate values of particular components.

  13. Radiation tests on selected electrical insulating materials for high-power and high voltage application

    International Nuclear Information System (INIS)

    Liptak, G.; Schuler, R.; Haberthuer, B.; Mueller, H.; Zeier, W.; Maier, P.; Schoenbacher, H.

    1985-01-01

    This report presents a comprehensive set of test results on the irradiation of insulating materials and systems used for the windings of rotating machines, dry-type transformers, and magnet coils. The materials were: Novolac, bisphenol-A, and cycloaliphatic types of epoxy; saturated and unsaturated polyesterimide; silicone, phenolic, and acrylic resins. The reinforcement consisted of glass mat, glass roving, glass cloth, mica paper, polyester mat, polyester roving, polyester cloth, aromatic polyamide paper, or combinations thereof. The materials were irradiated in an 8 MW pool reactor up to integrated doses of 10 8 Gy. On most samples, flexural properties were examined as recommended by IEC Standard 544. For tapes and varnishes, the breakdown voltage was measured. The adhesion of copper bars glued together with an epoxy resin was examined by means of a lap-shear test. A cupping test by means of the Erichsen apparatus was used to measure the flexibility of varnishes. The results are presented in tables and graphs for each of the materials tested. Those from mechanical tests show that the radiation resistance of composite resin-rich insulations depends not only on the base resin combination and the reinforcement material but, to a large degree, also on the adhesion between the two. It appears that better adhesion, and consequently higher radiation resistance, is obtained by special surface treatments of glass fibres. For laminates, higher radiation resistance is obtained with glass mat and resin combinations than with glass cloth as reinforcing materials. The breakdown voltage tests show that the application of mechanical stress to most irradiated samples causes the insulation layer to crack, resulting in lower dielectric strength. For a number of materials, the critical properties of flexural strength and breakdown voltage are above 50% of the initial value at doses between 10 7 and 10 8 Gy, i.e. a radiation index of 7 to 8 at 10 5 Gy/h. (orig.)

  14. Carbon nanotube wires and cables: Near-term applications and future perspectives

    Science.gov (United States)

    Jarosz, Paul; Schauerman, Christopher; Alvarenga, Jack; Moses, Brian; Mastrangelo, Thomas; Raffaelle, Ryne; Ridgley, Richard; Landi, Brian

    2011-11-01

    Wires and cables are essential to modern society, and opportunities exist to develop new materials with reduced resistance, mass, and/or susceptibility to fatigue. This article describes how carbon nanotubes (CNTs) offer opportunities for integration into wires and cables for both power and data transmission due to their unique physical and electronic properties. Macroscopic CNT wires and ribbons are presently shown as viable replacements for metallic conductors in lab-scale demonstrations of coaxial, USB, and Ethernet cables. In certain applications, such as the outer conductor of a coaxial cable, CNT materials may be positioned to displace metals to achieve substantial benefits (e.g. reduction in cable mass per unit length (mass/length) up to 50% in some cases). Bulk CNT materials possess several unique properties which may offer advantages over metallic conductors, such as flexure tolerance and environmental stability. Specifically, CNT wires were observed to withstand greater than 200,000 bending cycles without increasing resistivity. Additionally, CNT wires exhibit no increase in resistivity after 80 days in a corrosive environment (1 M HCl), and little change in resistivity with temperature (electrical conductivity of CNT materials must be improved. Recently, the conductivity of a CNT wire prepared through simultaneous densification and doping has exceeded 1.3 × 106 S/m. This level of conductivity brings CNTs closer to copper (5.8 × 107 S/m) and competitive with some metals (e.g. gold) on a mass-normalized basis. Developments in manipulation of CNT materials (e.g. type enrichment, doping, alignment, and densification) have shown progress towards this goal. In parallel with efforts to improve bulk conductivity, integration of CNT materials into cabling architectures will require development in electrical contacting. Several methods for contacting bulk CNT materials to metals are demonstrated, including mechanical crimping and ultrasonic bonding, along with a

  15. Development of signal processing electronics for self powered neutron detector signal with built-in on-line insulation monitoring [Paper No.:E3

    International Nuclear Information System (INIS)

    Das, Amitabha; Chaganty, S.P.

    1993-01-01

    Self powered neutron detectors (SPNDs) are employed to monitor in-core neutron flux in nuclear reactors for control, safety and mapping of in-core neutron flux. The d.c. current produced by SPND is converted into a proportional d.c. voltage, which in turn is used for various purposes stated above. This paper describes various features of the SPND amplifier developed in the Electronics Division of Bhabha Atomic Research Centre (BARC). It also outlines the principle of working of on-line monitoring of insulation resistance (IR) of the detector and associated mineral insulated (MI) and soft cables. The amplifier generates an alarm in case of the IR of the detector and the cable assembly falls below an accepted value or the cable is not connected to the amplifier and relieves the operator from periodic and manual checking of each of the individual detectors and ensures the validity of the signal for further processing. (author). 3 figs

  16. Effect of resin composition to the electrical and mechanical properties of high voltage insulator material

    International Nuclear Information System (INIS)

    Totok Dermawan; Elin Nuraini; Suyamto

    2012-01-01

    A solid insulator manufacture of resins for high voltage with a variation of resin and hardener composition has been made. The purpose of research to know electrical and mechanical properties of high voltage insulator material of resin. To determine its electric properties, the material is tested its breakdown voltage and the flashover voltage that occurred on the surface. While to determine the mechanical properties were tested by measuring its strength with a tensile test. From testing with variety of mixed composition it is known that for composition between hardener and resin of 1 : 800 has most advantageous properties because it has good strength with a tensile strength of 19.86 MPa and enough high dielectric strength of 43.2 kV / mm). (author)

  17. Elasticity and mechanical advantage in cables and ropes

    International Nuclear Information System (INIS)

    O'Shea, M J

    2007-01-01

    The conditions under which one can gain mechanical advantage by pulling with a force F perpendicular to a cable (or rope) that is fixed at both ends are examined. While this is a commonly discussed example in introductory physics classes, its solution in terms of fundamental properties of the cable requires one to model the elasticity of the cable. This solution has several complex and interesting features, e.g. a large increase in the tension in the cable may occur upon application of F if (i) F lies in a certain range and (ii) the initial tension T 1 in the cable (before F is applied) satisfies T 1 < 0.0340 κ. Here, κ is the spring constant of a unit length of the cable. For steel cables and cables composed of other materials such as carbon nanorods where the elasticity is low, significant increases in tension are possible. Examples involving walking a tightrope and attempting to increase the tension in a rope hauling a load are considered. Two programs to solve the equations of this work are available in the electronic version of this journal

  18. Classification of PD sources in HV cables using neural networks and the LN-FDTD method

    Energy Technology Data Exchange (ETDEWEB)

    Barros, W.H.; Oliveira, R.M.; Sobrinho, C.L.; Leite, R.C. [Univ. Federal do Para, Para (Brazil). Dept. of Computational and Electrical Engineering

    2008-07-01

    Partial discharges can be generated by the presence of several defects, and are often the cause of failures in electrical equipment insulators. In this study, a local non-orthogonal finite difference time-domain method (LN-FDTD) was used to simulate the sources of partial discharges in a high voltage coaxial cable model. The artificial neural network (ANN) technique used a Marquandt-Levenberg training algorithm to detect and classify cable PD sources. A set of harmonics obtained from the difference between the registered signals in the time domain was used as part of the training procedure. A failure was inserted on an electrical cable in each simulation in order to obtain the correlated data. Input signals were injected using a voltage pulse represented by a Gaussian function. A total of 90 simulations were conducted to generate 360 data groups in order to consider 6 different types of failures. Results of the study showed that the method can be used to detect and classify partial discharges in cables. 12 refs., 21 figs.

  19. Survey of thermal insulation systems

    International Nuclear Information System (INIS)

    Kinoshita, Izumi

    1983-01-01

    Better thermal insulations have been developed to meet the growing demands of industry, and studies on thermal insulation at both high temperature and low temperature have been widely performed. The purpose of this survey is to summarize data on the performances and characteristics of thermal insulation materials and thermal insulation structures (for instance, gas cooled reactors, space vehicles and LNG storage tanks), and to discuss ravious problems regarding the design of thermal insulation structures of pool-type LMFBRs. (author)

  20. 7 CFR 1755.890 - RUS specification for filled telephone cables with expanded insulation.

    Science.gov (United States)

    2010-01-01

    .... Catch and weigh any water that leaks from the end of the cable during the one hour period. If no water leaks from the sample, carefully remove the water from the closure. Then carefully remove the jacket... in ANSI/ICEA S-84-608-1988, paragraph 9.1 using a test temperature of 80 ±1 °C. (2) Water penetration...

  1. Lightning simulation of a combined overhead line/cable connected GIS

    DEFF Research Database (Denmark)

    Kessel, Jakob; Atlason, Vioir; Bak, Claus Leth

    2008-01-01

    performance, compared to a system consisting solely of AIS connected thorugh overhead lines. The main purpose is to investigate whether overvoltage protection is necessary at the GIS busbar. Here, the price for a GIS SA is significantly more expensive than the price for an AIS SA. The analysis is conducted......The paper concerns different investigations of lightning simulation of a combined 170 kV overhead line/cable connected GIS. This is interesting due to the increasing amount of underground cables and GIS in the Danish transmission system. This creates a different system with respect to lightning...... by implementing a simulation model in PSCAD/EMTDC. Simulations are conducted for both SF and BFO where the overvoltage at the transformer are evaluated as this component has the lowest insulation strength. The overvoltages are evaluated for different front imes of the lightning surge, different soil resistivities...

  2. Development of a single-phase 30 m HTS power cable

    Science.gov (United States)

    Cho, Jeonwook; Bae, Joon-Han; Kim, Hae-Jong; Sim, Ki-Deok; Kim, Seokho; Jang, Hyun-Man; Lee, Chang-Young; Kim, Dong-Wook

    2006-05-01

    HTS power transmission cables appear to be the replacement and retrofitting of underground cables in urban areas and HTS power transmission cable offers a number of technical and economic merits compared to the normal conductor cable system. A 30 m long, single-phase 22.9 kV class HTS power transmission cable system has been developed by Korea Electrotechnology Research Institute (KERI), LS Cable Ltd., and Korea Institute of Machinery and Materials (KIMM), which is one of the 21st century frontier project in Korea since 2001. The HTS power cable has been developed, cooled down and tested to obtain realistic thermal and electrical data on HTS power cable system. The evaluation results clarified such good performance of HTS cable that DC critical current of the HTS cable was 3.6 kA and AC loss was 0.98 W/m at 1260 Arms and shield current was 1000 Arms. These results proved the basic properties for 22.9 kV HTS power cable. As a next step, we have been developing a 30 m, three-phase 22.9 kV, 50 MV A HTS power cable system and long term evaluation is in progress now.

  3. Defect Detection of Adhesive Layer of Thermal Insulation Materials Based on Improved Particle Swarm Optimization of ECT.

    Science.gov (United States)

    Wen, Yintang; Jia, Yao; Zhang, Yuyan; Luo, Xiaoyuan; Wang, Hongrui

    2017-10-25

    This paper studies the defect detection problem of adhesive layer of thermal insulation materials. A novel detection method based on an improved particle swarm optimization (PSO) algorithm of Electrical Capacitance Tomography (ECT) is presented. Firstly, a least squares support vector machine is applied for data processing of measured capacitance values. Then, the improved PSO algorithm is proposed and applied for image reconstruction. Finally, some experiments are provided to verify the effectiveness of the proposed method in defect detection for adhesive layer of thermal insulation materials. The performance comparisons demonstrate that the proposed method has higher precision by comparing with traditional ECT algorithms.

  4. Synthesis of one-dimensional metal-containing insulated molecular wire with versatile properties directed toward molecular electronics materials.

    Science.gov (United States)

    Masai, Hiroshi; Terao, Jun; Seki, Shu; Nakashima, Shigeto; Kiguchi, Manabu; Okoshi, Kento; Fujihara, Tetsuaki; Tsuji, Yasushi

    2014-02-05

    We report, herein, the design, synthesis, and properties of new materials directed toward molecular electronics. A transition metal-containing insulated molecular wire was synthesized through the coordination polymerization of a Ru(II) porphyrin with an insulated bridging ligand of well-defined structure. The wire displayed not only high linearity and rigidity, but also high intramolecular charge mobility. Owing to the unique properties of the coordination bond, the interconversion between the monomer and polymer states was realized under a carbon monoxide atmosphere or UV irradiation. The results demonstrated a high potential of the metal-containing insulated molecular wire for applications in molecular electronics.

  5. 5th Duisburg thermal insulation days. Fuenfte Duisburger Waermedaemm-Tage

    Energy Technology Data Exchange (ETDEWEB)

    Agst, J. (ed.)

    1989-01-01

    This volume contains 18 specialist lectures mainly about the problems of thermal insulation in industrial furnaces and facility engineering. Among the subjects are: formed parts, monolithic lining materials and fillers of vermiculite; pyro-block-modular systems for furnaces (of the company DYKO-Morgan Fasertechnik); microporous insulating materials (KAOWOOL); properties of lightweight refractory bricks; thermal insulation in induction furnaces; vacuum moulded parts in electric furnace engineering; high temperature insulating materials with ceramic fibres; microtherm insulating materials. (MM).

  6. Study of high field Nb3Sn superconducting dipoles: electrical insulation based made of ceramic and magnetic design

    International Nuclear Information System (INIS)

    Rochepault, E.

    2012-01-01

    In the framework of LHC upgrades, significant efforts are provided to design accelerator magnets using the superconducting alloy Nb 3 Sn, which allows to reach higher magnetic fields (≥12 T). The aim of this thesis is to propose new computation and manufacturing methods for high field Nb 3 Sn dipoles. A ceramic insulation, previously designed at CEA Saclay, has been tested for the first time on cables, in an accelerator magnet environment. Critical current measures, under magnetic field and mechanical stress, have been carried out in particular. With this test campaign, the current ceramic insulation has been shown to be too weak mechanically and the critical current properties are degraded. Then a study has been conducted, with the objective to improve the mechanical strength of the insulation and better distribute the stress inside the cable. Methods of magnetic design have also been proposed, in order to optimize the coils shape, while fulfilling constraints of field homogeneity, operational margins, forces minimization... Consequently, several optimization codes have been set up. They are based on new methods using analytical formulas. A 2D code has first been written for block designs. Then two 3D codes have been realized for the optimization of dipole ends. The former consists in modeling the coil with elementary blocs and the latter is based on a modeling of the superconducting cables with ribbons. These optimization codes allowed to propose magnetic designs for high field accelerator magnets. (author) [fr

  7. Polyethylene Nanocomposites for the Next Generation of Ultralow-Transmission-Loss HVDC Cables: Insulation Containing Moisture-Resistant MgO Nanoparticles.

    Science.gov (United States)

    Pourrahimi, Amir Masoud; Pallon, Love K H; Liu, Dongming; Hoang, Tuan Anh; Gubanski, Stanislaw; Hedenqvist, Mikael S; Olsson, Richard T; Gedde, Ulf W

    2016-06-15

    The use of MgO nanoparticles in polyethylene for cable insulation has attracted considerable interest, although in humid media the surface regions of the nanoparticles undergo a conversion to a hydroxide phase. A facile method to obtain MgO nanoparticles with a large surface area and remarkable inertness to humidity is presented. The method involves (a) low temperature (400 °C) thermal decomposition of Mg(OH)2, (b) a silicone oxide coating to conceal the nanoparticles and prevent interparticle sintering upon exposure to high temperatures, and (c) heat treatment at 1000 °C. The formation of the hydroxide phase on these silicone oxide-coated MgO nanoparticles after extended exposure to humid air was assessed by thermogravimetry, infrared spectroscopy, and X-ray diffraction. The nanoparticles showed essentially no sign of any hydroxide phase compared to particles prepared by the conventional single-step thermal decomposition of Mg(OH)2. The moisture-resistant MgO nanoparticles showed improved dispersion and interfacial adhesion in the LDPE matrix with smaller nanosized particle clusters compared with conventionally prepared MgO. The addition of 1 wt % moisture-resistant MgO nanoparticles was sufficient to decrease the conductivity of polyethylene 30 times. The reduction in conductivity is discussed in terms of defect concentration on the surface of the moisture-resistant MgO nanoparticles at the polymer/nanoparticle interface.

  8. Study of low-mass readout cables for the CBM Silicon Tracking System

    Energy Technology Data Exchange (ETDEWEB)

    Singla, Minni [Goethe Univ. Frankfurt am Main (Germany); GSI, Darmstadt (Germany); Collaboration: CBM-Collaboration

    2013-07-01

    The study of thin multi-line readout cables will be reported. The application is the Silicon Tracking System (STS) of the fixed-target heavy-ion experiment Compressed Baryonic Matter (CBM), under design at the forthcoming accelerator centre FAIR in Germany. These cables will bridge the distance between the microstrip sensors and the signal processing electronics placed at the periphery of the silicon tracking stations. Finite element simulations (using the TCAD package RAPHAEL) have been used to optimize the cables towards minimum possible Equivalent Noise Charge (ENC). Various trace geometries and trace materials have been explored. SPICE modelling has been implemented in Sentaurus Device to study the transmission loss in the cables. The simulations have been validated with measurements. Charge loss in cables of different lengths was determined by injecting charge pulses of known amplitude. An optimized cable design is reported yielding minimum ENC, material budget and transmission loss.

  9. Análisis de falla en cable de acero Análisis de falla en cable de acero

    Directory of Open Access Journals (Sweden)

    E. A. Ossa

    2005-12-01

    Full Text Available Este artículo describe el análisis de falla realizado en dos muestras de cables de acero que sufrieron falla súbita bajo condiciones de carga de trabajo normales. La falla fue causada por una carga menor a la capacidad nominal. Luego de inspección óptica se evidenció que la falla fue ocasionada por fatiga del material de uno de los cables.This paper describes the failure analysis of two wire ropes fractured during normal working conditions. The failure was caused by a load well below the nominal maximum resistance of the ropes. Optical microscopy indicated fatigue failure of one of the cables.

  10. APPLICATION OF POLYURETHANE FOAM FOR IMPACT ABSORPTION AND THERMAL INSULATION FOR RADIOACTIVE MATERIALS PACKAGINGS

    International Nuclear Information System (INIS)

    Smith, A; Glenn Abramczyk, G; Paul Blanton, P; Steve Bellamy, S; William Daugherty, W; Sharon Williamson, S

    2007-01-01

    Polyurethane foam has been widely used as an impact absorbing and thermal insulating material for large radioactive materials packages, since the 1980's. With the adoption of the regulatory crush test requirement, for smaller packages, polyurethane foam has been adopted as a replacement for cane fiberboard, because of its ability to withstand the crush test. Polyurethane foam is an engineered material whose composition is much more closely controlled than that of cane fiberboard. In addition, the properties of the foam can be controlled by controlling the density of the foam. The conditions under which the foam is formed, whether confined or unconfined have an affect on foam properties. The study reported here reviewed the application of polyurethane foam in RAM packagings and compared property values reported in the literature with published property values and test results for foam specimens taken from a prototype 9977 packaging. The study confirmed that, polyurethane foam behaves in a predictable and consistent manner and fully satisfies the functional requirements for impact absorption and thermal insulation

  11. Propagation Characteristics of Multilayer Hybrid Insulator-Metal-Insulator and Metal-Insulator-Metal Plasmonic Waveguides

    Directory of Open Access Journals (Sweden)

    M. Talafi Noghani

    2014-02-01

    Full Text Available Propagation characteristics of symmetrical and asymmetrical multilayer hybrid insulator-metal-insulator (HIMI and metal-insulator-metal (HMIM plasmonic slab waveguides are investigated using the transfer matrix method. Propagation length (Lp and spatial length (Ls are used as two figures of merit to qualitate the plasmonic waveguides. Symmetrical structures are shown to be more performant (having higher Lp and lower Ls, nevertheless it is shown that usage of asymmetrical geometry could compensate for the performance degradation in practically realized HIMI waveguides with different substrate materials. It is found that HMIM slab waveguide could support almost long-range subdiffraction plasmonic modes at dimensions lower than the spatial length of the HIMI slab waveguide.

  12. Thermocouple and controlling cables of electric penetrations for nuclear power stations. hermetization with glass-ceramic and glass-fiber materials

    International Nuclear Information System (INIS)

    Kostyukov, N.S.; Golovko, T.A.; Okhotnikova, G.G.

    1996-01-01

    New perspective technology for hermetization of cable ends for fabrication of hermetical inlets for NPPs with inorganic materials is developed. On the basis of the studies dielectric inorganic materials, resistive to γ-radiation and fire, are selected for creation of hermetically sealed inlets. Principally new methods for fabrication of hermoinlets is developed on the basis of metallic modules with fibre circuitously and ceramic hermetization units

  13. Effect of heat curing methods on the temperature history and strength development of slab concrete for nuclear power plant structures in cold climates

    International Nuclear Information System (INIS)

    Lee, Gun Cheol; Han, Min Cheol; Baek, Dae Hyun; Koh, Kyung Taek

    2012-01-01

    The objective of this study was to experimentally investigate the effect of heat curing methods on the temperature history and strength development of slab concrete exposed to -10 degrees Celsius. The goal was to determine proper heat curing methods for the protection of nuclear power plant structures against early-age frost damage under adverse (cold) conditions. Two types of methods were studied: heat insulation alone and in combination with a heating cable. For heat curing with heat insulation alone, either sawdust or a double layer bubble sheet (2-BS) was applied. For curing with a combination of heat insulation and a heating cable, an embedded heating cable was used with either a sawdust cover, a 2-BS cover, or a quadruple layer bubble sheet (4-BS) cover. Seven different slab specimens with dimensions of 1200, 600, 200 mm and a design strength of 27 MPa were fabricated and cured at -10 degrees Celsius for 7 d. The application of sawdust and 2-BS allowed the concrete temperature to fall below 0 degrees Celsius within 40 h after exposure to -10 degrees Celsius, and then, the temperature dropped to -10 degrees Celsius and remained there for 7 d owing to insufficient thermal resistance. However, the combination of a heating cable plus sawdust or 2-BS maintained the concrete temperature around 5 degrees Celsius for 7 d. Moreover, the combination of the heating cable and 4-BS maintained the concrete temperature around 10 degrees Celsius for 7 d. This was due to the continuous heat supply from the heating cable and the prevention of heat loss by the 4-BS. For maturity development, which is an index of early-age frost damage, the application of heat insulation materials alone did not allow the concrete to meet the minimum maturity required to protect against early-age frost damage after 7 d, owing to poor thermal resistance. However, the combination of the heating cable and the heat insulating materials allowed the concrete to attain the minimum maturity level after

  14. Quality analysis of superconducting wire and cable for SSC dipole magnets

    International Nuclear Information System (INIS)

    Pollock, D.A.

    1992-01-01

    This paper reports that a critical component of the SSC collider dipole magnets is superconducting cable. The uniformity and reliability requirements for the dipoles place stringent demands on the cable. These needs have been defined as various contract requirements in the material specifications for NbTi alloy, superconducting wire and cable. A supplied qualification program is being started by the SSCL with industry to establish reliable sources of superconductor cable. Key to this qualification program is the establishment by industry of detailed process methods and controls for wire and cable manufacture. To monitor conductor performance, a computer database is being developed by the SSCL Magnet Systems Division Quality Assurance Department. The database is part of a program for ensuring superconductor uniformity by focusing on the understanding and control of variation. A statistical and graphical summary of current data for key performance variables will be presented in light of the specification requirement for uniformity. Superconductor material characteristics to be addressed will include Wire Critical Current (I c ), Copper Ratio (Cu:SC), Wire Diameter, Wire Piece Length, and Cable Dimensional Control

  15. Uncertainty relations and topological-band insulator transitions in 2D gapped Dirac materials

    International Nuclear Information System (INIS)

    Romera, E; Calixto, M

    2015-01-01

    Uncertainty relations are studied for a characterization of topological-band insulator transitions in 2D gapped Dirac materials isostructural with graphene. We show that the relative or Kullback–Leibler entropy in position and momentum spaces, and the standard variance-based uncertainty relation give sharp signatures of topological phase transitions in these systems. (paper)

  16. Molecular dynamics study of water molecule diffusion in oil-paper insulation materials

    International Nuclear Information System (INIS)

    Liao Ruijin; Zhu Mengzhao; Yang Lijun; Zhou Xin; Gong Chunyan

    2011-01-01

    Moisture is an important factor that influences the safe operation of transformers. In this study, molecular dynamics was employed to investigate the diffusion behavior of water molecules in the oil-paper insulation materials of transformers. Two oil-cellulose models were built. In the first model, water molecules were initially distributed in oil, and in the second model, water molecules were distributed in cellulose. The non-bonding energies of interaction between water molecules and oil, and between water molecules and cellulose, were calculated by the Dreiding force field. The interaction energy was found to play a dominant role in influencing the equilibrium distribution of water molecules. The radial direction functions of water molecules toward oil and cellulose indicate that the hydrogen bonds between water molecules and cellulose are sufficiently strong to withstand the operating temperature of the transformer. Mean-square displacement analysis of water molecules diffusion suggests that water molecules initially distributed in oil showed anisotropic diffusion; they tended to diffuse toward cellulose. Water molecules initially distributed in cellulose diffused isotropically. This study provides a theoretical contribution for improvements in online monitoring of water in transformers, and for subsequent research on new insulation materials.

  17. Molecular dynamics study of water molecule diffusion in oil-paper insulation materials

    Energy Technology Data Exchange (ETDEWEB)

    Liao Ruijin [State Key Laboratory of Power Transmission Equipment and System Security and New Technology, Chongqing University, Chongqing 400044 (China); Zhu Mengzhao, E-mail: xiaozhupost@163.co [State Key Laboratory of Power Transmission Equipment and System Security and New Technology, Chongqing University, Chongqing 400044 (China); Yang Lijun; Zhou Xin; Gong Chunyan [State Key Laboratory of Power Transmission Equipment and System Security and New Technology, Chongqing University, Chongqing 400044 (China)

    2011-03-01

    Moisture is an important factor that influences the safe operation of transformers. In this study, molecular dynamics was employed to investigate the diffusion behavior of water molecules in the oil-paper insulation materials of transformers. Two oil-cellulose models were built. In the first model, water molecules were initially distributed in oil, and in the second model, water molecules were distributed in cellulose. The non-bonding energies of interaction between water molecules and oil, and between water molecules and cellulose, were calculated by the Dreiding force field. The interaction energy was found to play a dominant role in influencing the equilibrium distribution of water molecules. The radial direction functions of water molecules toward oil and cellulose indicate that the hydrogen bonds between water molecules and cellulose are sufficiently strong to withstand the operating temperature of the transformer. Mean-square displacement analysis of water molecules diffusion suggests that water molecules initially distributed in oil showed anisotropic diffusion; they tended to diffuse toward cellulose. Water molecules initially distributed in cellulose diffused isotropically. This study provides a theoretical contribution for improvements in online monitoring of water in transformers, and for subsequent research on new insulation materials.

  18. Material-controlled dynamic vacuum insulation

    Science.gov (United States)

    Benson, D.K.; Potter, T.F.

    1996-10-08

    A compact vacuum insulation panel is described comprising a chamber enclosed by two sheets of metal, glass-like spaces disposed in the chamber between the sidewalls, and a high-grade vacuum in the chamber includes apparatus and methods for enabling and disabling, or turning ``on`` and ``off`` the thermal insulating capability of the panel. One type of enabling and disabling apparatus and method includes a metal hydride for releasing hydrogen gas into the chamber in response to heat, and a hydrogen grate between the metal hydride and the chamber for selectively preventing and allowing return of the hydrogen gas to the metal hydride. Another type of enabling and disabling apparatus and method includes a variable emissivity coating on the sheets of metal in which the emissivity is controllably variable by heat or electricity. Still another type of enabling and disabling apparatus and method includes metal-to-metal contact devices that can be actuated to establish or break metal-to-metal heat paths or thermal short circuits between the metal sidewalls. 25 figs.

  19. Effect of electric field in the characterization of pultruded GFRP boron-free composite insulator for the extra high voltage by the ionizing radiation

    Energy Technology Data Exchange (ETDEWEB)

    Fujiwara, Hissae; Silva Junior, Edmilson Jose; Shinohara, Armando Hideki [Universidade Federal de Pernambuco (UFPE), Recife, PE (Brazil); Xavier, Gustavo Jose Vasconcelos [CHESF, Recife, PE (Brazil); Costa, Edson Guedes [Universidade Federal de Campina Grande (UFCG), PB (Brazil); Lott Neto, Henrique Batista Duffles Teixeira; Britto, Paulo Roberto Ranzan; Fontan, Marcio A.B. [Sistema de Transmissao do Nordeste S.A., Recife, PE (Brazil)

    2016-07-01

    Full text: The pultruded boron-free glass fiber reinforced polymer (GFRP) composite has been widely used material for the electrical insulators in the high, extra and ultra high voltage overhead lines worldwide. In terms of design, the composite insulator has a highly complex geometry and large size. Aging of materials begin as soon as the insulators start their operation due to the strong electric field, mechanical load due to the weight of conductor cables, environment, corona discharge, generation of acids, and as a result, GFRP can fail mechanically by the stress corrosion crack (SCC) and electrical breakdown known as flashover. In order to mitigate the mechanical and electrical failures, the insulators in the field are frequently monitored by visual inspection, infrared thermography, UV detection, variation of measurement of distribution of electric field variation. However, new technologies for characterization and inspection of the composite insulator in the field are required for reliable operation. Imaging characterization using ionizing radiation (X-ray or g-ray) is an interesting technique, however, it can reduce drastically breakdown voltage due to the Townsend discharge, which free electrons are accelerated by an electric field, collide with gas molecules of air, and free additional electrons resulting in an avalanche multiplication that allows an electrical conduction through the air. In this study, in order to evaluate the potential application of ionization radiation for characterization of composite insulator under electric field, testing were conducted in high voltage laboratory by applying voltages up to 640 kV and varying radiation area of the composite insulator. As a result, even though there was an occurrence of flame on Imaging Plate (IP) detector case when it was located near the phase, corona discharge, but no breakdown discharge (flashover) occurred and high quality imaging of radiography could be obtained when X-ray source was employed

  20. Simple model of cable-stayed bridge deck subjected to static wind loading

    Science.gov (United States)

    Kang, Yi-Lung; Wang, Yang Cheng

    1997-05-01

    Cable-stayed bridges have been known since 18th century with aesthetics design. The structural system and the structural behavior are significantly different from those of continuous bridges. Compared to continuous bridge, cable- stayed bridges have more flexure bridge deck than those of continuous bridges.On the other hand, cable-stayed bridges have less stiffness to resist wind loading especially for lateral loads. The first considering of bridge engineering is safety. In 1940's, Tacoma Narrows Suspension Bridge destroyed by wind loading is a good example even though it is not a cable-stayed bridge. After the bridge was destroyed, a lot of research articles have been published regarding cable supported bridge subjected to wind loading. In recent days, high strength materials have been served. The bridge engineers use the advantages to expand the span length of cable-stayed bridges. Due to the span length increased and the use of high strength materials, cable- stayed bridges have more significant nonlinear behavior subjected to wind loading. In this paper, a slice bridge deck of cable-stayed bridge connected to internal support cables is considered. The deck has been considered to be subjected to lateral static wind loading. Since cables can not take compressive force, the deck has strongly nonlinear behavior even though the materials are linear elastic. Several primary load combinations have ben considered in this paper such as the bridge deck supposed to be moved horizontally without rotation or the bridge deck supposed to be moved horizontally with rotational deformation. The mathematical formulas and the numerical solutions are found and represented in graphical forms. The results can be provided to bridge designers and researchers for further study of this type of structure subjected to wind loading.

  1. Lambda as a factor for saving energy. When are special high-performance insulating materials worthwhile?; Einsparfaktor Lambda. Wann rechnen sich besonders leistungsfaehige Daemmstoffe?

    Energy Technology Data Exchange (ETDEWEB)

    Tornow, Sven-Erik [Arbeitskreis Baufachpresse e.V., Koeln (Germany)

    2011-01-15

    The probably most important criterion of an insulating material is its specific thermal conductivity. The so-called lambda value describes the amount of heat which flows in one second at a temperature difference of one Kelvin through one square meters of a one meter thick layer of a material. The lower the lambda-value, the much better. While usual insulating materials exist in the heat conductance stages 035 to 045, in the meantime the manufactures overestimate oneself with super-insulating materials whose thermal conductivity reach a value of 0.019. VIP panels have a heat conductivity to approximately 0.006 W/(m{sup 2} K). This is a high damming performance,which has its price.

  2. Comparison of Conductor-Temperature Calculations Based on Different Radial-Position-Temperature Detections for High-Voltage Power Cable

    Directory of Open Access Journals (Sweden)

    Lin Yang

    2018-01-01

    Full Text Available In this paper, the calculation of the conductor temperature is related to the temperature sensor position in high-voltage power cables and four thermal circuits—based on the temperatures of insulation shield, the center of waterproof compound, the aluminum sheath, and the jacket surface are established to calculate the conductor temperature. To examine the effectiveness of conductor temperature calculations, simulation models based on flow characteristics of the air gap between the waterproof compound and the aluminum are built up, and thermocouples are placed at the four radial positions in a 110 kV cross-linked polyethylene (XLPE insulated power cable to measure the temperatures of four positions. In measurements, six cases of current heating test under three laying environments, such as duct, water, and backfilled soil were carried out. Both errors of the conductor temperature calculation and the simulation based on the temperature of insulation shield were significantly smaller than others under all laying environments. It is the uncertainty of the thermal resistivity, together with the difference of the initial temperature of each radial position by the solar radiation, which led to the above results. The thermal capacitance of the air has little impact on errors. The thermal resistance of the air gap is the largest error source. Compromising the temperature-estimation accuracy and the insulation-damage risk, the waterproof compound is the recommended sensor position to improve the accuracy of conductor-temperature calculation. When the thermal resistances were calculated correctly, the aluminum sheath is also the recommended sensor position besides the waterproof compound.

  3. Cable line engineering

    International Nuclear Information System (INIS)

    Jang, Hak Sin; Kim, Sin Yeong

    1998-02-01

    This book is about cable line engineering. It is comprised of nine chapters, which deals with summary of cable communication such as way, process of cable communication and optical communication, Line constant of transmission on primary constant, reflection and crosstalk, communication cable line of types like flat cable, coaxial cable and loaded cable, Install of communication line with types and facility of aerial line, construction method of communication line facility, Measurement of communication line, Carrier communication of summary, PCM communication with Introduction, regeneration relay system sampling and quantization and Electric communication service and general information network with mobile communication technique and satellite communication system.

  4. Synthesis of Macroporous Silica Particles by Continuous Generation of Droplets for Insulating Materials.

    Science.gov (United States)

    Cho, Young-Sang; Lee, Dokyoung

    2018-09-01

    We report on the synthesis of porous silica particles by self-assembly routes in a continuous manner for application to thermal insulators. A continuous process was employed to produce tiny droplets containing precursor materials such as silica and organic templates for self-organization to fabricate particles with well defined pores. A rotating cylinder system or a spray drying process was adopted to form emulsions or aerosol droplets as micro-reactors for self-assembly, and the physical properties including the thermal conductivity of the resulting porous particles were compared between the two methods. The porous particles could be coated as a thick film by solution dripping, and the fluorination treatment using a silane coupling agent was performed to produce superhydrophobic surfaces of insulating layers by a lotus effect.

  5. Investigation and analysis on ITER in-vessel coils’ raw-materials

    International Nuclear Information System (INIS)

    Jin, Huan; Wu, Yu; Long, Feng; Yu, Min; Han, Qiyang; Liu, Huajun

    2013-01-01

    Highlights: • The R and D works for the ITER in-vessel coils (IVC) are now being conducted in Institute of Plasma Physics, and the analysis work are being done by Princeton Plasma Physics Laboratory. • There is little published paper about the raw materials for ITER IVC coils. • This manuscript points out the progress of the selected materials for ITER IVC coils. -- Abstract: The ITER in-vessel coils (IVCs) consist of 27 coils edge localized modes (ELM) and 2 coils vertical stabilization (VS) which are all mounted on the vacuum vessel wall behind the shield modules. The IVCs design and manufacturing work is being conducted in between Institute of Plasma Physics Chinese Academy of Sciences (ASIPP) and Princeton Plasma Physics Laboratory (PPPL). Because the position of ELM and VS coils is close and face to the plasma, the IVCs must undergo a severe environment, such as the high dose of radiation and high operation temperature, thus the conventional electrical insulation materials cannot be used. And the technology of “Stainless Steel Jacketed Mineral Insulated Conductor” (SSMIC) is deemed as the best choice to provide the necessary radiation resistance and compatibility strength in ITER's vacuum vessel. While mineral insulated conductor technology is not new, and is similar to the mineral insulated cable used in industrial. Some difficulties still need to be solved, such as searching for the proper raw-materials to make sure that the conductor have the properties of high current carrying capability, the necessary radiation resistance, the proper strength, at the same time, it must be come true in manufacture technology. This paper described the analysis of the materials for VS and ELM coil conductor

  6. Fire safety requirements for electric cables and lines in deep coal mines

    Energy Technology Data Exchange (ETDEWEB)

    Herms, C D

    1982-01-07

    In the case of a mine fire, an additional hazard from combustible cable material is likely to arise only in those few areas of the mine where special circumstances might help the fire to spread along the cables. It is more important to preserve the functional integrity of cables in the outbye roads which are affected by fire gases then at the actual seat of the fire. Mine cables with better fire-resistant properties should be made from materials which do not propagate fires, do not release burning drops, develop the lowest possible fume density and/or will permanently resist gas temperatures of 200 to 300/sup 0/C. Fire test specifications should be defined for such special cables, based on corresponding draft VDE directives. In proposing these measures the proviso is made then improvement in safety can be clearly demonstrated.

  7. Heat resistant wire and cable and heat shrinkable tubes

    Energy Technology Data Exchange (ETDEWEB)

    Ueno, Keiji [Sumitomo Electric Industries Ltd. (Japan)

    1994-12-31

    Radiation processes have been used in industrial fields (e.g. wire and cable, heat shrinkable tubes) for about 30 years. In Japan, 60 electron beam accelerators were used in R and D, 54 in wire and cable, 24 in tire rubber, 16 in paint curing, 14 in PE foam and 9 accelerators were used in heat shrinkable tubes in 1993. Many properties (e.g. solder resistance, thermal deformation, and solven resistance) of wire and cable are improved by using radiation processes, and many kinds of radiation crosslinked wire and cable are used in the consumer market (TV sets, VTR`s, audio disc players, etc.), automobiles (automobile wire harnesses, fusible link wires, sensor cables etc.), and the industrial market (computer cables, cables for keyboards, coaxial cables, etc.). Another important industrial application of E{beta} radiation process is heat shrinkable tubes. Heat shinkable tubes, heated by a hot gun, shrink 1/2 {approx} 1/3 of their inner diameters. Heat shrinkable tubes are used for covers of distributing line terminals, joint covers of telecommunication lines, protection of fuel pipe lines and so on. In this seminar, actual applications and characteristic properties of radiation crosslinked materials are presented.

  8. Heat resistant wire and cable and heat shrinkable tubes

    International Nuclear Information System (INIS)

    Keiji Ueno

    1994-01-01

    Radiation processes have been used in industrial fields (e.g. wire and cable, heat shrinkable tubes) for about 30 years. In Japan, 60 electron beam accelerators were used in R and D, 54 in wire and cable, 24 in tire rubber, 16 in paint curing, 14 in PE foam and 9 accelerators were used in heat shrinkable tubes in 1993. Many properties (e.g. solder resistance, thermal deformation, and solven resistance) of wire and cable are improved by using radiation processes, and many kinds of radiation crosslinked wire and cable are used in the consumer market (TV sets, VTR's, audio disc players, etc.), automobiles (automobile wire harnesses, fusible link wires, sensor cables etc.), and the industrial market (computer cables, cables for keyboards, coaxial cables, etc.). Another important industrial application of Eβ radiation process is heat shrinkable tubes. Heat shinkable tubes, heated by a hot gun, shrink 1/2 ∼ 1/3 of their inner diameters. Heat shrinkable tubes are used for covers of distributing line terminals, joint covers of telecommunication lines, protection of fuel pipe lines and so on. In this seminar, actual applications and characteristic properties of radiation crosslinked materials are presented

  9. THE INFLUENCE OF ECOLOGICAL MATERIALS EMBEDDED INTO COMPOSITES UPON THE THERMAL INSULATING CAPACITY

    Directory of Open Access Journals (Sweden)

    Luminiţa-Maria BRENCI

    2014-12-01

    Full Text Available The paper presents the results of a research performed in order to design and manufacture composites that embed in their structure ecological raw materials, such as wood chips and hemp hurds. The thermal conductivity was determined for a temperature difference (ΔT of 200 C between the cold plate and warm plate and the measurements were done in eight points. The results showed that the best insulating composite material was obtained for the structure containing equal shares of wood chips and chopped hemp

  10. Development of polymer concrete for dike insulation at LNG facilities: Phase 4, Low cost materials

    Energy Technology Data Exchange (ETDEWEB)

    Kukacka, L.E.

    1991-01-01

    Earlier GRI-sponsored work at Brookhaven National Laboratory has resulted in the development and utilization of insulating polymer concrete composites (IPC) as a means of reducing the evaporation rate of liquified natural gas in the event of a spill into a containment dike, thereby improving the safety at these sites. Although all of the required properties can be attained with the IPC, it was estimated that a low-cost replacement for the expensive organic binder would be necessary before use of the material would be cost-effective. In the current program, several latex modified cement formulations were evaluated and the most promising one identified. A mixture of two carboxylated styrene-butadiene latexes was selected for use in detailed laboratory property characterizations and a subsequent field evaluation. When compared to the properties of IPC, the latex-modified insulating materials display somewhat higher thermal conductivities, greater permeability to water, and reduced strength. However, these properties still meet most of the performance criteria, and the unit cost of the material is less than one-fifth that of IPC made with epoxy binders. When installed as a 0.75-in. thick overlay, material costs are estimated to be $1.00/ft{sup 2}.

  11. Design, processing, and properties of Bi 2212\\/Ag Rutherford cables

    CERN Document Server

    Collings, E W; Scanlan, R M; Dietderich, D R; Motowidlo, L R; Sokolowski, R S; Aoki, Y; Hasegawa, T

    1999-01-01

    In a program intended to explore the use of high temperature superconducting (HTSC) cables in high field synchrotron dipole magnets model Bi:2212/Ag Rutherford cables were designed bearing in mind the needs for mechanical integrity, relatively high tensile strength, and low coupling losses. To satisfy these needs a core-type cable design was selected and a readily available heat-resistant core material acquired. Cables were wound for critical current- and AC loss measurement. Both winding-induced (mechanical) and core-induced (chemical) critical current degradation was examined. Interstrand coupling loss was measured calorimetrically on model cable samples with bare- and oxide-coated cores. From the results it was predicted that the losses of full-scale Bi:2212/Ag-wound LHC-type Rutherford cables would fall close to the acceptability range for the windings of high-field accelerator dipoles. (10 refs).

  12. Colloquium 3: Thermal insulation materials in construction and in high-temperature plants. Lectures; Kolloquium 3: Waermedaemmstoffe im Bauwesen und in Hochtemperaturanlagen. Vortraege

    Energy Technology Data Exchange (ETDEWEB)

    Schlegel, E.; Gross, U.; Walter, G. [comps.

    1999-07-01

    Colloquium 3, ''Thermal insulation materials in construction and in high-temperature plants'' focused, for one thing, on the inter-relationships between the development of thermal insulation materials for construction and high-temperature applications and the development of processes and plants and, for another, on the standards of and amendments to the thermal protection ordinance. Calcium silicate and Silcapor as a thermal protection material and a high-temperature thermal insulant, respectively, are dealt with inter alia. The use of thermal insulants in industrial furnaces and different methods for measuring thermal conductivity are described. Further topics are the elements of the energy conservation ordinance being drafted, and thermal-insulation construction materials such as bricks and foam mortar. Ten papers are individually listed in the Energy database. (orig.) [German] Im Mittelpunkt des Kolloquium 3 ''Waermedaemmstoffe im Bauwesen und in Hochtemperaturanlagen'' stehen die wechselseitigen Zusammenhaenge zwischen der Entwicklung von Waermedaemmstoffen fuer das Bauwesen und die Hochtemperaturanwendung einerseits und der Prozess-und Anlagenentwicklung anderseits sowie die Normung und die Novellierung der Waermeschutzverordnung. Es wird u.a. auf den Waermedaemmstoff Calciumsilicat eingegangen ebensowie auf Silcapor als Hochtemperaturd ammstoff. Der Einsatz von Waermedaemmstoffen in Industrieoefen sowie die unterschiedlichen Messmethoden der Waermeleitfaehigkeit werden beschrieben. Weitere Themen sind die Grundlagen der kuenftigen Energiesparverordnung sowie waermedaemmende Baustoffe wie Ziegel und Porenbeton. Fuer die Datenbank Energy wurden zehn Arbeiten separat aufgenommen.

  13. Results of radiation tests at cryogenic temperature on some selected organic materials for the LHC

    International Nuclear Information System (INIS)

    Schoenbacher, H.; Szeless, B.; Tavlet, M.; Humer, K.; Weber, H.W.

    1996-01-01

    Future multi-TeV particle accelerators like the CERN Large Hadron Collider (LHC) will use superconducting magnets where organic materials will be exposed to high radiation levels at temperatures as low as 2 K. A representative selection of organic materials comprising insulating films, cable insulations, and epoxy-type impregnated resins were exposed to neutron and gamma radiation of a nuclear reactor. Depending on the type of materials, the integrated radiation doses varied between 180 kGy and 155 MGy. During irradiation, the samples were kept close to the boiling temperature of liquid nitrogen i.e. ∼ 80 K and thereafter stored in liquid nitrogen and transferred at the same temperature into the testing device for measurement of tensile and flexural strength. Tests were carried out on the same materials at similar dose rates at room temperature, and the results were compared with those obtained at cryogenic temperature. They show that, within the selected dose range, a number of organic materials are suitable for use in the radiation field of the LHC at cryogenic temperature. (orig.)

  14. Compliance of Bombardier's Challenger 604 and CRJ200 to FAR25.856(a) : flame propagation of thermal/acoustic insulation materials and future trends in aircraft materials fire safety

    Energy Technology Data Exchange (ETDEWEB)

    Lewis, W.R. [Bombardier, Montreal, PQ (Canada); Schofield, C.M.A. [Transport Canada, Ottawa, ON (Canada)

    2007-07-01

    This paper provided details of a testing program designed to ensure the compliance of Bombardier's Challenger 604 to new rules established to improve flammability standards for thermal and acoustic insulation materials. The rule applied to both pressurized and unpressurized sections of the fuselage, as well as to ducting, sound damping foams, and insulation bags. Test samples of all non-metallic insulation components were collected. Testing of the samples was conducted in a chamber with an ignition source as well as a controlled heat flux provided by a radiant panel. The new rules were discussed as well as challenges faced by industry which will have to show compliance for flame propagation requirements. Issues related to the in-service replacement of thermal and acoustic insulation materials were reviewed along with potential changes to flammability regulations. Materials used by Bombardier for compliant constructions were also listed. It was concluded that the safety of airplane occupants will be improved through compliance to new testing methods under harsher fire threat conditions, with more stringent pass and fail criteria. 15 refs., 5 figs.

  15. Static and Dynamic Characteristics of a Long-Span Cable-Stayed Bridge with CFRP Cables

    Directory of Open Access Journals (Sweden)

    Xu Xie

    2014-06-01

    Full Text Available In this study, the scope of CFRP cables in cable-stayed bridges is studied by establishing a numerical model of a 1400-m span of the same. The mechanical properties and characteristics of CFRP stay cables and of a cable-stayed bridge with CFRP cables are here subjected to comprehensive analysis. The anomalies in the damping properties of free vibration, nonlinear parametric vibration and wind fluctuating vibration between steel cables and CFRP cables are determined. The structural stiffness, wind resistance and traffic vibration of the cable-stayed bridge with CFRP cables are also analyzed. It was found that the static performances of a cable-stayed bridge with CFRP cables and steel cables are basically the same. The natural frequencies of CFRP cables do not coincide with the major natural frequencies of the cable-stayed bridge, so the likelihood of CFRP cable-bridge coupling vibration is minuscule. For CFRP cables, the response amplitudes of both parametric vibration and wind fluctuating vibration are smaller than those of steel cables. It can be concluded from the research that the use of CFRP cables does not change the dynamic characteristics of the vehicle-bridge coupling vibration. Therefore, they can be used in long-span cable-stayed bridges with an excellent mechanical performance.

  16. Static and Dynamic Characteristics of a Long-Span Cable-Stayed Bridge with CFRP Cables.

    Science.gov (United States)

    Xie, Xu; Li, Xiaozhang; Shen, Yonggang

    2014-06-23

    In this study, the scope of CFRP cables in cable-stayed bridges is studied by establishing a numerical model of a 1400-m span of the same. The mechanical properties and characteristics of CFRP stay cables and of a cable-stayed bridge with CFRP cables are here subjected to comprehensive analysis. The anomalies in the damping properties of free vibration, nonlinear parametric vibration and wind fluctuating vibration between steel cables and CFRP cables are determined. The structural stiffness, wind resistance and traffic vibration of the cable-stayed bridge with CFRP cables are also analyzed. It was found that the static performances of a cable-stayed bridge with CFRP cables and steel cables are basically the same. The natural frequencies of CFRP cables do not coincide with the major natural frequencies of the cable-stayed bridge, so the likelihood of CFRP cable-bridge coupling vibration is minuscule. For CFRP cables, the response amplitudes of both parametric vibration and wind fluctuating vibration are smaller than those of steel cables. It can be concluded from the research that the use of CFRP cables does not change the dynamic characteristics of the vehicle-bridge coupling vibration. Therefore, they can be used in long-span cable-stayed bridges with an excellent mechanical performance.

  17. Interfacial Coatings for Inorganic Composite Insulation Systems

    International Nuclear Information System (INIS)

    Hooker, M. W.; Fabian, P. E.; Stewart, M. W.; Grandlienard, S. D.; Kano, K. S.

    2006-01-01

    Inorganic (ceramic) insulation materials are known to have good radiation resistance and desirable electrical and mechanical properties at cryogenic and elevated temperatures. In addition, ceramic materials can withstand the high-temperature reaction cycle used with Nb3Sn superconductor materials, allowing the insulation to be co-processed with the superconductor in a wind-and-react fabrication process. A critical aspect in the manufacture of ceramic-based insulation systems is the deposition of suitable fiber-coating materials that prevent chemical reaction of the fiber and matrix materials, and thus provide a compliant interface between the fiber and matrix, which minimizes the impact of brittle failure of the ceramic matrix. Ceramic insulation produced with CTD-FI-202 fiber interfaces have been found to exhibit very high shear and compressive strengths. However, this material is costly to produce. Thus, the goal of the present work is to evaluate alternative, lower-cost materials and processes. A variety of oxide and polyimide coatings were evaluated, and one commercially available polyimide coating has been shown to provide some improvement as compared to uncoated and de-sized S2 glass

  18. THERMAL INSULATION PROPERTIES RESEARCH OF THE COMPOSITE MATERIAL WATER GLASS–GRAPHITE MICROPARTICLES

    Directory of Open Access Journals (Sweden)

    V. A. Gostev

    2014-05-01

    Full Text Available Research results for the composite material (CM water glass–graphite microparticles with high thermal stability and thermal insulation properties are given. A composition consisting of graphite (42 % by weight, water glass Na2O(SiO2n (50% by weight and the hardener - sodium silicofluoric Na2SiF6 (8% by weight. Technology of such composition receipt is suggested. Experimental samples of the CM with filler particles (graphite and a few microns in size were obtained. This is confirmed by a study of samples by X-ray diffraction and electron microscopy. The qualitative and quantitative phase analysis of the CM structure is done. Load limit values leading to the destruction of CM are identified. The character of the rupture surface is detected. Numerical values of specific heat and thermal conductivity are defined. Dependence of the specific heat capacity and thermal conductivity on temperature at monotonic heating is obtained experimentally. Studies have confirmed the increased thermal insulation properties of the proposed composition. CM with such characteristics can be recommended as a coating designed to reduce heat losses and resistant to high temperatures. Due to accessibility and low cost of its components the proposed material can be produced on an industrial scale.

  19. Proposal for the award of a contract for the supply of polyimide film for cable and ground insulation of the LHC superconducting magnets

    CERN Document Server

    1999-01-01

    This document concerns the award of a contract for the supply of up to 79 tonnes of polyimide film, of three different types, for cable and ground insulation of the LHC superconducting magnets. A call for tenders (IT-2679/LHC/LHC) was sent on 21 September 1999 to two firms in Japan and one firm in the USA. By the closing date, CERN had received three tenders. The Finance Committee is invited to agree to the negotiation of a contract with the firm KANEKA (JP), the lowest bidder, for the supply of 79 tonnes of polyimide film of three different types for an amount of 5 425 541 USD (8 123 284 Swiss francs) for the polyimide film produced in the USA, not subject to revision, and 725 726 546 Japanese yen (10 109 020 Swiss francs) for the polyimide film produced in Japan, not subject to revision, with an option for the supply of up to 20% additional polyimide film of each type, for an amount of 1 085 108 USD (1 624 657 Swiss francs) and 145 145 309 Japanese yen (2 021 804 Swiss francs) respectively, not subject to r...

  20. Metal-insulator transition and superconductivity in heavily boron-doped diamond and related materials

    Energy Technology Data Exchange (ETDEWEB)

    Achatz, Philipp

    2009-05-15

    During this PhD project, the metal-insulator transition and superconductivity of highly boron-doped single crystal diamond and related materials have been investigated. The critical boron concentration n{sub c} for the metal-insulator transition was found to be the same as for the normal-superconductor transition. All metallic samples have been found to be superconducting and we were able to link the occurence of superconductivity to the proximity to the metal-insulator transition. For this purpose, a scaling law approach based on low temperature transport was proposed. Furthermore, we tried to study the nature of the superconductivity in highly boron doped single crystal diamond. Raman spectroscopy measurements on the isotopically substituted series suggest that the feature occuring at low wavenumbers ({approx} 500 cm{sup -1}) is the A1g vibrational mode associated with boron dimers. Usual Hall effect measurements yielded a puzzling situation in metallic boron-doped diamond samples, leading to carrier concentrations up to a factor 10 higher than the boron concentration determined by secondary ion mass spectroscopy (SIMS). The low temperature transport follows the one expected for a granular metal or insulator, depending on the interplay of intergranular and intragranular (tunneling) conductance. The metal-insulator transition takes place at a critical conductance g{sub c}. The granularity also influences significantly the superconducting properties by introducing the superconducting gap {delta} in the grain and Josephson coupling J between superconducting grains. A peak in magnetoresistance is observed which can be explained by superconducting fluctuations and the granularity of the system. Additionally we studied the low temperature transport of boron-doped Si samples grown by gas immersion laser doping, some of which yielded a superconducting transition at very low temperatures. Furthermore, preliminary results on the LO-phonon-plasmon coupling are shown for the

  1. Metal-insulator transition and superconductivity in heavily boron-doped diamond and related materials

    International Nuclear Information System (INIS)

    Achatz, Philipp

    2009-01-01

    During this PhD project, the metal-insulator transition and superconductivity of highly boron-doped single crystal diamond and related materials have been investigated. The critical boron concentration n c for the metal-insulator transition was found to be the same as for the normal-superconductor transition. All metallic samples have been found to be superconducting and we were able to link the occurence of superconductivity to the proximity to the metal-insulator transition. For this purpose, a scaling law approach based on low temperature transport was proposed. Furthermore, we tried to study the nature of the superconductivity in highly boron doped single crystal diamond. Raman spectroscopy measurements on the isotopically substituted series suggest that the feature occuring at low wavenumbers (∼ 500 cm -1 ) is the A1g vibrational mode associated with boron dimers. Usual Hall effect measurements yielded a puzzling situation in metallic boron-doped diamond samples, leading to carrier concentrations up to a factor 10 higher than the boron concentration determined by secondary ion mass spectroscopy (SIMS). The low temperature transport follows the one expected for a granular metal or insulator, depending on the interplay of intergranular and intragranular (tunneling) conductance. The metal-insulator transition takes place at a critical conductance g c . The granularity also influences significantly the superconducting properties by introducing the superconducting gap Δ in the grain and Josephson coupling J between superconducting grains. A peak in magnetoresistance is observed which can be explained by superconducting fluctuations and the granularity of the system. Additionally we studied the low temperature transport of boron-doped Si samples grown by gas immersion laser doping, some of which yielded a superconducting transition at very low temperatures. Furthermore, preliminary results on the LO-phonon-plasmon coupling are shown for the first time in aluminum

  2. Final Report: MATERIALS, STRANDS, AND CABLES FOR SUPERCONDUCTING ACCELERATOR MAGNETS [Grant Number DE-SC0010312

    Energy Technology Data Exchange (ETDEWEB)

    Sumption, Mike D. [The Ohio State Univ., Columbus, OH (United States). Center for Superconducting and Magnetic Materials (CSMM); Collings, Edward W. [The Ohio State Univ., Columbus, OH (United States). Center for Superconducting and Magnetic Materials (CSMM)

    2014-10-29

    Our program consisted of the two components: Strand Research and Cable Research, with a focus on Nb3Sn, Bi2212, and YBCO for accelerator magnet applications. We demonstrated a method to refine the grains in Nb3Sn by a factor of two, reaching 45 nm grain sizes, and layer Jcs of 6 kA/mm2 at 12 T. W also measured conductor magnetization for field quality. This has been done both with Nb3Sn conductor, as well as Bi:2212 strand. Work in support of quench studies of YBCO coils was also performed. Cable loss studies in Nb3Sn focused on connecting and comparing persistent magnetization and coupling magnetization for considering their relative impact on HEP machines. In the area of HTS cables, we have investigated both the quench in multistrand YBCO CORC cables, as well as the magnetization of these cables for use in high field magnets. In addition, we examined the magnetic and thermal properties of large (50 T) solenoids.

  3. Static and Dynamic Mechanical Properties of Long-Span Cable-Stayed Bridges Using CFRP Cables

    Directory of Open Access Journals (Sweden)

    Mei Kuihua

    2017-01-01

    Full Text Available The elastic modulus and deadweight of carbon fiber-reinforced polymer (CFRP cables are different from those of steel cables. Thus, the static and dynamic behaviors of cable-stayed bridges using CFRP cables are different from those of cable-stayed bridges using steel cables. The static and dynamic performances of the two kinds of bridges with a span of 1000 m were studied using the numerical method. The effects of geometric nonlinear factors on static performance of the two kinds of cable-stayed bridges were analyzed. The live load effects and temperature effects of the two cable-stayed bridges were also analyzed. The influences of design parameters, including different structural systems, the numbers of auxiliary piers, and the space arrangement types of cable, on the dynamic performance of the cable-stayed bridge using CFRP cables were also studied. Results demonstrate that sag effect of the CFRP cable is much smaller than that of steel cable. The temperature effects of CFRP cable-stayed bridge are less than those of steel cable-stayed bridge. The vertical bending natural vibration frequency of the CFRP cable-stayed bridge is generally lower than that of steel cable-stayed bridge, whereas the torsional natural vibration frequency of the former is higher than that of the latter.

  4. On the Minimum Cable Tensions for the Cable-Based Parallel Robots

    Directory of Open Access Journals (Sweden)

    Peng Liu

    2014-01-01

    Full Text Available This paper investigates the minimum cable tension distributions in the workspace for cable-based parallel robots to find out more information on the stability. First, the kinematic model of a cable-based parallel robot is derived based on the wrench matrix. Then, a noniterative polynomial-based optimization algorithm with the proper optimal objective function is presented based on the convex optimization theory, in which the minimum cable tension at any pose is determined. Additionally, three performance indices are proposed to show the distributions of the minimum cable tensions in a specified region of the workspace. An important thing is that the three performance indices can be used to evaluate the stability of the cable-based parallel robots. Furthermore, a new workspace, the Specified Minimum Cable Tension Workspace (SMCTW, is introduced, within which all the minimum tensions exceed a specified value, therefore meeting the specified stability requirement. Finally, a camera robot parallel driven by four cables for aerial panoramic photographing is selected to illustrate the distributions of the minimum cable tensions in the workspace and the relationship between the three performance indices and the stability.

  5. Universal Cable Brackets

    Science.gov (United States)

    Vanvalkenburgh, C.

    1985-01-01

    Concept allows routing easily changed. No custom hardware required in concept. Instead, standard brackets cut to length and installed at selected locations along cable route. If cable route is changed, brackets simply moved to new locations. Concept for "universal" cable brackets make it easy to route electrical cable around and through virtually any structure.

  6. Using of Aerogel to Improve Thermal Insulating Properties of Windows

    Science.gov (United States)

    Valachova, Denisa; Zdrazilova, Nada; Panovec, Vladan; Skotnicova, Iveta

    2018-06-01

    For the best possible thermal-technical properties of building structures it is necessary to use materials with very low thermal conductivity. Due to the increasing thermal-technical requirements for building structures, the insulating materials are developed. One of the modern thermal insulating materials is so-called aerogel. Unfortunately, this material is not used in the field of external thermal insulation composite systems because of its price and its properties. The aim of this paper is to present possibilities of using this insulating material in the civil engineering - specifically a usage of aerogel in the production of windows.

  7. Continuous operation of NPP Kori Unit 1 - Fireproof paint for cables

    International Nuclear Information System (INIS)

    Wendt, Dipl-Ing. Ruediger; Kim, Duill; Sik, Cho Hong

    2008-01-01

    Fireproof cable coating materials have been used in European NPP, especially in Germany, Russia, Ukraine, Czech Republic, Lithuania, Switzerland. Wide experiences were made during operation while applying these systems. In NPP Kori, Unit 1, a fire proof cable coating project was realised for the first time in a NPP of KHNP. The scope of services of the cable trays to coat amounts to 15,587m 2 . In different fire compartments and rooms the cables should be coated partially respectively completely with the fire proof cable coating system. The extent of cable surfaces to coat was stipulated by KHNP on the basis of an analysis made by KHNP. The project was tendered on the basis of a technical specification of KHNP. The specification is mainly predicted on Korean and US standards. The most important criteria for the fire proof cable coating is resumed as follows: The fireproof cable coating has to assure the fire protection of the cables for a period defined and for operational conditions defined in such a manner that the general conditions for the operation of the cable installation will not be affected

  8. Heat insulating structure for use in transporting and handling gas of high temperature and pressure

    International Nuclear Information System (INIS)

    Mathusima, T.; Sato, T.; Uenishi, A.

    1980-01-01

    A heat insulating structure is described that has a heat-resistant tube disposed in a tubular cylindrical body and defining a passage for a high temperature gas, a heat insulating material disposed between the tube and the tubular cylindrical body and adapted to prevent the heat possessed by the gas from being transmitted to the tubular cylindrical body, and a spring adapted to bias the heat insulating material toward the inner surface of the tubular cylindrical body, so as to prevent the formation of a bypass passage for the gas including the gap between the tubular cylindrical body and the heat insulating material. The heat insulating material consists of a plurality of fibrous heat insulating materials mainly consisting of bulky fibrous materials and a plurality of shaped fibrous heat insulating materials. These fibrous heat insulating materials and the shaped fibrous heat insulating materials are arranged alternatingly and independently in the axial direction. In each of the bulky fibrous heat insulating material, disposed is a spring for biasing the shaped fibrous heat insulating material in the axial direction

  9. Insulating Foams Save Money, Increase Safety

    Science.gov (United States)

    2009-01-01

    Scientists at Langley Research Center created polyimide foam insulation for reusable cryogenic propellant tanks on the space shuttle. Meanwhile, a small Hialeah, Florida-based business, PolyuMAC Inc., was looking for advanced foams to use in the customized manufacturing of acoustical and thermal insulation. The company contacted NASA, licensed the material, and then the original inventors worked with the company's engineers to make a new material that was better for both parties. The new version, a high performance, flame retardant, flexible polyimide foam, is used for insulating NASA cryogenic propellant tanks and shows promise for use on watercraft, aircraft, spacecraft, electronics and electrical products, automobiles and automotive products, recreation equipment, and building and construction materials.

  10. Wind-induced cable vibrations and countermeasures of cables of PC cable-stayed bridge. PC syachokyo keburu no kaze ni yoru shindo to sono taisaku

    Energy Technology Data Exchange (ETDEWEB)

    Yoneda, M. (Kawada Industries Inc., Tokyo (Japan))

    1994-05-01

    In recent years, long span of cable-stayed bridges is remarkable. The wind-induced cable vibration called as line vibration and wake galloping was given as an important problem not only in the steel cable-stayed bridges but also in the PC cable-stayed bridges. The technical engineers in design of the cable-stayed bridges have many times to confront the problems on the vibration control of cables, it is considered that sufficient understand of the wind-induced vibration and countermeasures for cables of the PC cable-stayed bridges is necessary. Many reports on the countermeasure examples and trend of vibration control centred on cables of the cable-stayed bridges have been published. In this paper, the wind-induced vibration of cables in the cable-stayed bridges was reviewed, the examples of countermeasures of vibration control on cables in the PC cable-stayed bridges was mainly introduced. The remaining tasks and future prospects on vibration control of the PC cable-stayed bridges were described. 14 refs., 13 figs., 4 tabs.

  11. High performance thermal insulation systems (HiPTI). Vacuum insulated products (VIP). Proceedings of the international conference and workshop

    Energy Technology Data Exchange (ETDEWEB)

    Zimmermann, M.; Bertschinger, H.

    2001-07-01

    These are the proceedings of the International Conference and Workshop held at EMPA Duebendorf, Switzerland, in January 2001. The papers presented at the conference's first day included contributions on the role of high-performance insulation in energy efficiency - providing an overview of available technologies and reviewing physical aspects of heat transfer and the development of thermal insulation as well as the state of the art of glazing technologies such as high-performance and vacuum glazing. Also, vacuum-insulated products (VIP) with fumed silica, applications of VIP systems in technical building systems, nanogels, VIP packaging materials and technologies, measurement of physical properties, VIP for advanced retrofit solutions for buildings and existing and future applications for advanced low energy building are discussed. Finally, research and development concerning VIP for buildings are reported on. The workshops held on the second day covered a preliminary study on high-performance thermal insulation materials with gastight porosity, flexible pipes with high performance thermal insulation, evaluation of modern insulation systems by simulation methods as well as the development of vacuum insulation panels with a stainless steel envelope.

  12. Vibration based monitoring of stay cable force using wireless piezoelectric based strain sensor nodes

    International Nuclear Information System (INIS)

    Nguyen, Khac Duy; Kim, Jeong Tae

    2012-01-01

    This study presents a method to monitor cable force using wireless sensor nodes and piezoelectric sensors. The following approaches are carried out to achieve the objective. Firstly, the principle of piezoelectric materials (e.g., PZT) as strain sensors is reviewed. A cable force estimation method using dynamic features of cables measured by piezoelectric materials is presented. Secondly, the design of an automated cable force monitoring system using the data acquisition sensor node Imote2/SHM DAQ is described. The sensor node is originally developed by University of Illinois at Urbana champaign and is adopted in this study to monitor strain induced voltage from PZT sensors. The advantages of the system are cheap, and eligible for wireless communication and automated operation. Finally, the feasibility of the proposed monitoring system is evaluated on a lab scaled cable

  13. Method of manufacturing a thermally insulating body

    Energy Technology Data Exchange (ETDEWEB)

    McWilliams, J.A.; Morgan, D.E.; Jackson, J.D.

    1988-10-11

    A method of manufacturing a microporous thermally insulating body comprises mixing together a finely divided microporous insulating material such as silica aerogel or pyrogenic silica and a solid ammonia-generating compound in particulate form, and compressing the mixture to form a thermally insulating body. The ammonia-generating compound is dispersed evenly throughout the insulating material and may comprise, for example, ammonium carbonate, ammonium acetate or urea. Preferably, the ammonia-generating compound comprises a mixture of about one third by weight of ammonium carbonate and about two thirds by weight of ammonium bicarbonate together with a small proportion of magnesium oxide. Experiments are described which illustrate the manufacturing process. 6 tabs.

  14. Light fireproof insulating plate-formed material

    Energy Technology Data Exchange (ETDEWEB)

    Plum, B.A.; Juhl, L.F.

    1981-02-23

    Light fireproof insulating plates were produced by pressure processing of a mixture of rice-husk ashes with pearlite aluminium phosphate and glass wool. The corn size of pearlite is 0-5 mm., of rice-husk ashes 0-5 mm. and the fiber length of fibrous additive is about 25 mm.

  15. Stator winding service life analysis of wet winding motor RCP

    International Nuclear Information System (INIS)

    Yeoh Eingyee; Li Linsen; Wang Ziguan; Shen Feng

    2017-01-01

    The reactor coolant pump type RUV of KSB is specially designed for the Westinghouse AP1000 reactor. It is hermetically sealed, wet winding motor pump. This wet winding motor concept has higher efficiency as compared to a canned motor since there are no eddy current losses, but this makes the stator cable insulator face the challenge of degradation by γ-irradiation in coolant. Radiation dose at the RUV is evaluated in interest from the material degradation point of view and the service life of stator winding in RUV is preliminarily analyzed. The values obtained are less than the dose rate and the dose which change the mechanical properties of the insulator material. According to the preliminary analysis, it can be concluded that the degradation of cable insulator of stator winding by γ-irradiation in coolant is negligible for the 60 years' service life of reactor coolant pump. This result also ensures crosslinked polyethylene used as cable insulator of stator winding is reliable in reactor coolant pump. (author)

  16. The Effect of Moisture and Fungus on Electrical and Mechanical Properties of Plastic Insulating Materials

    Science.gov (United States)

    1945-10-01

    0110 106 280000 46000 7.6 30000 6.2 27000 4.2 24000 1.2 10000 Samples and eleotrode arrangement were humidity exposure tests« aa...VARIOUS INSULATING MATERIALS TEMPERATURE 25°C.; RELATIVE HUMIDITY 979b; EXCEPT WHERE NOTED OTHERWISE 140 160 ISO 200 220 240 260 270

  17. Development of new materials by utilizing radiation crosslinking

    International Nuclear Information System (INIS)

    Ueno, Keiji; Uda, Yujiro; Suzuki, Shizuo

    1989-01-01

    About 30 years have elapsed since the cables by electron beam crosslinking were developed as the first industrial utilization of radiation in Japan. At present about 200 electron beam accelerators are used industrially in Japan, and cable industry ranks at the top, followed by foaming polyethylene and curing, and the preliminary vulcanization of tires. The effect of these irradiations is the reforming of polymers by radiation crosslinking. In cables, the heat resistance and chemical resistance of insulators are improved by radiation crosslinking. By applying radiation crosslinking to polyurethane elastomer, its weakest point, waterproof property, was improved. Moreover, by using this crosslinked polyurethane elastomer for cable coating, the reliability of the sensor cables for brake system was able to be remarkably improved. As another new application of radiation crosslinking process, the improvement of the heat resistance of engineering plasties was examined. The structure of radiation crosslinked urethane elastomer cables, their endurance in hot water and oil, and the life, and the characteristics of sensor cables are reported. Multi-functional monomers, the molecular structure, and the various characteristics of engineering plastics are described. (K.I.)

  18. Light Water Reactor Sustainability Program: Evaluation of Localized Cable Test Methods for Nuclear Power Plant Cable Aging Management Programs

    Energy Technology Data Exchange (ETDEWEB)

    Glass, Samuel W. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Fifield, Leonard S. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Hartman, Trenton S. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States)

    2016-05-30

    This Pacific Northwest National Laboratory (PNNL) milestone report describes progress to date on the investigation of nondestructive test (NDE) methods focusing particularly on local measurements that provide key indicators of cable aging and damage. The work includes a review of relevant literature as well as hands-on experimental verification of inspection capabilities. As NPPs consider applying for second, or subsequent, license renewal (SLR) to extend their operating period from 60 years to 80 years, it important to understand how the materials installed in plant systems and components will age during that time and develop aging management programs (AMPs) to assure continued safe operation under normal and design basis events (DBE). Normal component and system tests typically confirm the cables can perform their normal operational function. The focus of the cable test program is directed toward the more demanding challenge of assuring the cable function under accident or DBE. Most utilities already have a program associated with their first life extension from 40 to 60 years. Regrettably, there is neither a clear guideline nor a single NDE that can assure cable function and integrity for all cables. Thankfully, however, practical implementation of a broad range of tests allows utilities to develop a practical program that assures cable function to a high degree. The industry has adopted 50% elongation at break (EAB) relative to the un-aged cable condition as the acceptability standard. All tests are benchmarked against the cable EAB test. EAB is a destructive test so the test programs must apply an array of other NDE tests to assure or infer the overall set of cable’s system integrity. These cable NDE programs vary in rigor and methodology. As the industry gains experience with the efficacy of these programs, it is expected that implementation practice will converge to a more common approach. This report addresses the range of local NDE cable tests that are

  19. On the mechanism of charge transport in low density polyethylene

    Science.gov (United States)

    Upadhyay, Avnish K.; Reddy, C. C.

    2017-08-01

    Polyethylene based polymeric insulators, are being increasingly used in the power industry for their inherent advantages over conventional insulation materials. Specifically, modern power cables are almost made with these materials, replacing the mass-impregnated oil-paper cable technology. However, for ultra-high dc voltage applications, the use of these polymeric cables is hindered by ununderstood charge transport and accumulation. The conventional conduction mechanisms (Pool-Frenkel, Schottky, etc.) fail to track high-field charge transport in low density polyethylene, which is semi-crystalline in nature. Until now, attention was devoted mainly to the amorphous region of the material. In this paper, authors propose a novel mechanism for conduction in low density polyethylene, which could successfully track experimental results. As an implication, a novel, substantial relationship is established for electrical conductivity that could be effectively used for understanding conduction and breakdown in polyethylene, which is vital for successful development of ultra-high voltage dc cables.

  20. Experimental characterization of shape memory alloy actuator cables

    Science.gov (United States)

    Biggs, Daniel B.; Shaw, John A.

    2016-04-01

    Wire rope (or cables) are a fundamental structural element in many engineering applications. Recently, there has been growing interest in stranding NiTi wires into cables to scale up the adaptive properties of NiTi tension elements and to make use of the desirable properties of wire rope. Exploratory experiments were performed to study the actuation behavior of two NiTi shape memory alloy cables and straight monofilament wire of the same material. The specimens were held under various dead loads ranging from 50 MPa to 400 MPa and thermally cycled 25 times from 140°C to 5°C at a rate of 12°C/min. Performance metrics of actuation stroke, residual strain, and work output were measured and compared between specimen types. The 7x7 cable exhibited similar actuation to the single straight wire, but with slightly longer stroke and marginally more shakedown, while maintaining equivalent specific work output. This leads to the conclusion that the 7x7 cable effectively scaled up the adaptive properties the straight wire. Under loads below 150 MPa, the 1x27 cable had up to double the actuation stroke and work output, but exhibited larger shakedown and poorer performance when loaded higher.