WorldWideScience

Sample records for button-head tensile specimen

  1. LPTR irradiation of LLL vanadium tensile specimens and LLL Nb--1Zr tensile specimens

    International Nuclear Information System (INIS)

    MacLean, S.C.; Rowe, C.L.

    1977-01-01

    The LPTR irradiation of 14 LLL vanadium tensile specimens and 14 LLL Nb-1Zr tensile specimens is described. Sample packaging, the irradiation schedule and neutron fluences for three energy ranges are given

  2. Optimization of tensile method and specimen geometry in modified ring tensile test

    International Nuclear Information System (INIS)

    Kitano, Koji; Fuketa, Toyoshi; Sasajima, Hideo; Uetsuka, Hiroshi

    2001-03-01

    Several techniques in ring tensile test are proposed in order to evaluate mechanical properties of cladding under hoop loading condition caused by pellet/cladding mechanical interaction (PCMI). In the modified techniques, variety of tensile methods and specimen geometry are being proposed in order to limit deformation within the gauge section. However, the tensile method and the specimen geometry were not determined in the modified techniques. In the present study, we have investigated the tensile method and the specimen geometry through finite element method (FEM) analysis of specimen deformation and tensile test on specimens with various gauge section geometries. In using two-piece tensile tooling, the mechanical properties under hoop loading condition can be correctly evaluated when deformation part (gauge section) is put on the top of a half-mandrel, and friction between the specimen and the half-mandrel is reduced with Teflon tape. In addition, we have shown the optimum specimen geometry for PWR 17 by 17 type cladding. (author)

  3. Miniature tensile test specimens for fusion reactor irradiation studies

    International Nuclear Information System (INIS)

    Klueh, R.L.

    1985-01-01

    Three miniature sheet-type tensile specimens and a miniature rod-type specimen are being used to determine irradiated tensile properties for alloy development for fusion reactors. The tensile properties of type 316 stainless steel were determined with these different specimens, and the results were compared. Reasonably good agreement was observed. However, there were differences that led to recommendations on which specimens are preferred. 4 references, 9 figures, 6 tables

  4. Tensile-Creep Test Specimen Preparation Practices of Surface Support Liners

    Science.gov (United States)

    Guner, Dogukan; Ozturk, Hasan

    2017-12-01

    Ground support has always been considered as a challenging issue in all underground operations. Many forms of support systems and supporting techniques are available in the mining/tunnelling industry. In the last two decades, a new polymer based material, Thin Spray-on Liner (TSL), has attained a place in the market as an alternative to the current areal ground support systems. Although TSL provides numerous merits and has different application purposes, the knowledge on mechanical properties and performance of this material is still limited. In laboratory studies, since tensile rupture is the most commonly observed failure mechanism in field applications, researchers have generally studied the tensile testing of TSLs with modification of American Society for Testing and Materials (ASTM) D-638 standards. For tensile creep testing, specimen preparation process also follows the ASTM standards. Two different specimen dimension types (Type I, Type IV) are widely preferred in TSL tensile testing that conform to the related standards. Moreover, molding and die cutting are commonly used specimen preparation techniques. In literature, there is a great variability of test results due to the difference in specimen preparation techniques and practices. In this study, a ductile TSL product was tested in order to investigate the effect of both specimen preparation techniques and specimen dimensions under 7-day curing time. As a result, ultimate tensile strength, tensile yield strength, tensile modulus, and elongation at break values were obtained for 4 different test series. It is concluded that Type IV specimens have higher strength values compared to Type I specimens and moulded specimens have lower results than that of prepared by using die cutter. Moreover, specimens prepared by molding techniques have scattered test results. Type IV specimens prepared by die cutter technique are suggested for preparation of tensile test and Type I specimens prepared by die cutter technique

  5. Design and use of nonstandard tensile specimens for irradiated materials testing

    International Nuclear Information System (INIS)

    Panayotou, N.F.

    1984-10-01

    Miniature, nonstandard, tensile-type specimens have been developed for use in radiation effects experiments at high energy neutron sources where the useful radiation volume is as small as a few cubic centimeters. The end result of our development is a sheet-type specimen, 12.7 mm long with a 5.1 mm long, 1.0 mm wide gage section, which is typically fabricated from 0.25 mm thick sheet stock by a punching technique. Despite this miniature geometry, it has been determined that the data obtained using these miniature specimens are in good agreement with data obtained using much larger specimens. This finding indicates that miniature tensile specimen data may by used for engineering design purposes. Furthermore, it is clear that miniature tensile specimen technology is applicable to fields other than the study of radiation effects. This paper describes the miniature specimen technology which was developed and compares the data obtained from these miniature specimens to data obtained from much larger specimens. 9 figures

  6. Polystyrene cryostat facilitates testing tensile specimens under liquid nitrogen

    Science.gov (United States)

    Shogan, R. P.; Skalka, R. J.

    1967-01-01

    Lightweight cryostat made of expanded polystyrene reduces eccentricity in a tensile system being tested under liquid nitrogen. The cryostat is attached directly to the tensile system by a special seal, reducing misalignment effects due to cryostat weight, and facilitates viewing and loading of the specimens.

  7. Use of miniature tensile specimen and video extensometer for measurement of mechanical properties

    International Nuclear Information System (INIS)

    Kumar, Kundan; Pooleery, Arun; Madhusoodanan, K.

    2014-08-01

    Miniaturisation of the tensile test specimen below the sub-size level poses various challenges, such as conformity of specimen to various acceptance criteria as per standard test specimen, aspect ratio, minimum number of grains required in a gauge cross-section, fabrication for uniformity in metrological values, etc. Apart from these, measurement of strain over a very limited available space on the test specimen is another practical challenge. Despite these limitations, miniature specimen testing is increasingly being used worldwide these days. The driving forces behind increasing use of miniature test techniques are new material development, assuring fitness of component after in-service-inspection, low dose of radiation exposure due to smaller dimensions of test specimens etc. However, the evaluation of mechanical properties from a miniature tensile test has a greater advantage over the other miniature novel test techniques, such as small punch test, ABI, miniature fatigue and impact tests etc., as it is a direct method of measurement of mechanical properties. This report covers various aspects of miniature tensile test methodologies, which include geometrical design of specimen having gauge length of 3-5 mm, fabrication, development of special fixtures for gripping the test specimens, and use of optical method for strain measurement. The geometrical design of the specimen and its behaviour over application of tensile load has been established using FEM analysis. A good agreement between conventional and miniature test results exemplifies the potential of the miniature tensile test technique. (author)

  8. An automated tensile machine for small specimens heavily neutron irradiated in FFTF/MOTA

    International Nuclear Information System (INIS)

    Kohyama, Akira; Sato, Shinji; Hamada, Kenichi

    1993-01-01

    The objective of this work is to develop a fully automated tensile machine for post-irradiation examination (PIE) of Fast Flux Test Facility (FFTF)/Materials Open Test Assembly (MOTA) irradiated miniature tension specimens. The anticipated merit of the automated tensile machine is to reduce damage to specimens during specimen handling for PIE and to reduce exposure to radioactive specimens. This machine is designed for testing at elevated temperatures, up to 873 K, in a vacuum or in an inert gas environment. Twelve specimen assemblies are placed in the vacuum chamber that can be tested successively in a fully automated manner. A unique automated tensile machine for the PIE of FFTF/MOTA irradiated specimens, the Monbusho Automated Tensile Machine (MATRON) consists of a test frame with controlling units and an automated specimen-loading apparatus. The qualification of the test frame has been completed, and the results have satisfied the machine specifications. The capabilities of producing creep and relaxation data have been demonstrated for Cu, Al, 316SS, and ferritic steels. The specimen holders for the three-point bending test and the small bulge test (small punch test; SP test) were also designed and produced

  9. Tensile tests and metallography of brazed AISI 316L specimens after irradiation

    International Nuclear Information System (INIS)

    Groot, P.; Franconi, E.

    1994-01-01

    Stainless steel type 316L tensile specimens were vacuum brazed with three kinds of alloys: BNi-5, BNi-6, and BNi-7. The specimens were irradiated up to 0.7 dpa at 353 K in the High Flux Reactor at JRC Petten, the Netherlands. Tensile tests were performed at a constant displacement rate of 10 -3 s -1 at room temperature in the ECN hot cell facility. BNi-5 brazed specimens showed ductile behaviour. Necking and fractures were localized in the plate material. BNi-6 and BNi-7 brazed specimens failed brittle in the brazed zone. This was preceded by uniform deformation of the plate material. Tensile test results of irradiated specimens showed higher stresses due to radiation hardening and a reduction of the elongation of the plate material compared to the reference. SEM examination of the irradiated BNi-6 and BNi-7 fracture surfaces showed nonmetallic phases. These phases were not found in the reference specimens. ((orig.))

  10. Elastic-plastic analysis of the SS-3 tensile specimen

    International Nuclear Information System (INIS)

    Majumdar, S.

    1998-01-01

    Tensile tests of most irradiated specimens of vanadium alloys are conducted using the miniature SS-3 specimen which is not ASTM approved. Detailed elastic-plastic finite element analysis of the specimen was conducted to show that, as long as the ultimate to yield strength ratio is less than or equal to 1.25 (which is satisfied by many irradiated materials), the stress-plastic strain curve obtained by using such a specimen is representative of the true material behavior

  11. A Study on Mechanical behavior of Tensile Specimen Fabricated by Laser Cutting

    Energy Technology Data Exchange (ETDEWEB)

    Jin, Y. G.; Kim, G. S.; Baik, S. J.; Baek, S. Y. [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2016-10-15

    The mechanical testing data are required for the assessment of dry storage of the spent nuclear fuel. Laser cutting system could be useful tools for material processing such as cutting in radioactive environment due to non-contact nature, ease in handling and the laser cutting process is most advantageous, offering the narrow kerf width and heat affected zone by using small beam spot diameter. The feasibility of the laser cutting system was demonstrated for the fabrication of various types of the unirradiated cladding with and without oxide layer on the specimens. In the present study, the dimensional measurement and tensile test were conducted to investigate the mechanical behavior of the axial tensile test specimens depending on the material processing methods in a hot cell at IMEF (Irradiated Materials Examination Facility) of KAERI. Laser cutting system was used to fabricate the tensile test specimens, and the mechanical behavior was investigated using the dimensional measurement and tensile test. It was shown that the laser beam machining could be a useful tool to fabricate the specimens and this technique will be developed for the fabrication of various types of irradiated specimens in a hotcell.

  12. A Study on Mechanical behavior of Tensile Specimen Fabricated by Laser Cutting

    International Nuclear Information System (INIS)

    Jin, Y. G.; Kim, G. S.; Baik, S. J.; Baek, S. Y.

    2016-01-01

    The mechanical testing data are required for the assessment of dry storage of the spent nuclear fuel. Laser cutting system could be useful tools for material processing such as cutting in radioactive environment due to non-contact nature, ease in handling and the laser cutting process is most advantageous, offering the narrow kerf width and heat affected zone by using small beam spot diameter. The feasibility of the laser cutting system was demonstrated for the fabrication of various types of the unirradiated cladding with and without oxide layer on the specimens. In the present study, the dimensional measurement and tensile test were conducted to investigate the mechanical behavior of the axial tensile test specimens depending on the material processing methods in a hot cell at IMEF (Irradiated Materials Examination Facility) of KAERI. Laser cutting system was used to fabricate the tensile test specimens, and the mechanical behavior was investigated using the dimensional measurement and tensile test. It was shown that the laser beam machining could be a useful tool to fabricate the specimens and this technique will be developed for the fabrication of various types of irradiated specimens in a hotcell

  13. Life prediction methodology for ceramic components of advanced vehicular heat engines: Volume 3, Appendices 3, 4, 5, 6, and 7. Final report

    Energy Technology Data Exchange (ETDEWEB)

    Khandelwal, P.K.; Provenzano, N.J.; Schneider, W.E. [Allison Engine Co., Indianapolis, IN (United States)

    1996-02-01

    The appendices contain: dynamic fatigue testing of MOR specimens in air at Allison from 1000 to 1400 C; dynamic fatigue testing of MOR specimens in air and Ar at ORNL from 1000-1400 C; dynamic fatigue testing of button-head tensile specimens in air at Southern Research Institute; tensile creep curves for dogbone specimens tested at the National Institute of Science and Technology; and oxidation behavior of PY-6 Si nitride between 1000-1400 C in air.

  14. Validatin of miniaturised tensile testing on DMLS TI6AL4V (ELI specimens

    Directory of Open Access Journals (Sweden)

    Van Zyl, Ian

    2016-11-01

    Full Text Available Direct metal laser sintering (DMLS is a relatively new technology that is developing rapidly. Since DMLS material is created by melting/solidifying tracks and layers from powder, even building geometry can influence the mechanical properties. To certify a material, the testing specimens must be designed and manufactured according to the appropriate standards. Miniaturised tensile DMLS samples could be a good alternative for express quality control, and could reduce the cost of DMLS-specific testing. In this study, as-built and stress-relieved miniaturised tensile DMLS Ti6Al4V (ELI specimens with different surface qualities were investigated. The fracture surfaces and mechanical properties of the mini-tensile specimens were analysed and compared with standard full-sized specimens also manufactured by DMLS. The obtained data showed the applicability of mini-tensile tests for the express analysis of DMLS objects if a correction factor is applied for the calculation of the load-bearing cross-section of the specimen.

  15. Stress Wave Attenuation in Aluminum Alloy and Mild Steel Specimens Under SHPB Tensile Testing

    Science.gov (United States)

    Pothnis, J. R.; Ravikumar, G.; Arya, H.; Yerramalli, Chandra S.; Naik, N. K.

    2018-02-01

    Investigations on the effect of intensity of incident pressure wave applied through the striker bar on the specimen force histories and stress wave attenuation during split Hopkinson pressure bar (SHPB) tensile testing are presented. Details of the tensile SHPB along with Lagrangian x- t diagram of the setup are included. Studies were carried out on aluminum alloy 7075 T651 and IS 2062 mild steel. While testing specimens using the tensile SHPB setup, it was observed that the force calculated from the transmitter bar strain gauge was smaller than the force obtained from the incident bar strain gauge. This mismatch between the forces in the incident bar and the transmitter bar is explained on the basis of stress wave attenuation in the specimens. A methodology to obtain force histories using the strain gauges on the specimen during SHPB tensile testing is also presented. Further, scanning electron microscope images and photomicrographs are given. Correlation between the microstructure and mechanical properties is explained. Further, uncertainty analysis was conducted to ascertain the accuracy of the results.

  16. Tensile and Creep Testing of Sanicro 25 Using Miniature Specimens

    Science.gov (United States)

    Dymáček, Petr; Jarý, Milan; Dobeš, Ferdinand; Kloc, Luboš

    2018-01-01

    Tensile and creep properties of new austenitic steel Sanicro 25 at room temperature and operating temperature 700 °C were investigated by testing on miniature specimens. The results were correlated with testing on conventional specimens. Very good agreement of results was obtained, namely in yield and ultimate strength, as well as short-term creep properties. Although the creep rupture time was found to be systematically shorter and creep ductility lower in the miniature test, the minimum creep rates were comparable. The analysis of the fracture surfaces revealed similar ductile fracture morphology for both specimen geometries. One exception was found in a small area near the miniature specimen edge that was cut by electro discharge machining, where an influence of the steel fracture behavior at elevated temperature was identified. PMID:29337867

  17. Tensile and Creep Testing of Sanicro 25 Using Miniature Specimens.

    Science.gov (United States)

    Dymáček, Petr; Jarý, Milan; Dobeš, Ferdinand; Kloc, Luboš

    2018-01-16

    Tensile and creep properties of new austenitic steel Sanicro 25 at room temperature and operating temperature 700 °C were investigated by testing on miniature specimens. The results were correlated with testing on conventional specimens. Very good agreement of results was obtained, namely in yield and ultimate strength, as well as short-term creep properties. Although the creep rupture time was found to be systematically shorter and creep ductility lower in the miniature test, the minimum creep rates were comparable. The analysis of the fracture surfaces revealed similar ductile fracture morphology for both specimen geometries. One exception was found in a small area near the miniature specimen edge that was cut by electro discharge machining, where an influence of the steel fracture behavior at elevated temperature was identified.

  18. Evaluation of miniature tensile specimen fabrication techniques and performance

    Energy Technology Data Exchange (ETDEWEB)

    Hamilton, M.L. (Pacific Northwest Lab., Richland, WA (United States)); Blotter, M.A.; Edwards, D.J. (Missouri Univ., Rolla, MO (United States))

    1992-01-01

    The confident application of miniature tensile specimens requires adequate control over their fabrication and is facilitated by automated test and analysis techniques. Three fabrication processes -- punching, chemical, milling, and electrical discharge machining (EDM) -- were recently evaluated, leading to the replacement of the previously used punching technique with a wire EDM technique. The automated data acquisition system was upgraded, and an interactive data analysis program was developed.

  19. Evaluation of miniature tensile specimen fabrication techniques and performance

    International Nuclear Information System (INIS)

    Hamilton, M.L.; Blotter, M.A.; Edwards, D.J.

    1992-01-01

    The confident application of miniature tensile specimens requires adequate control over their fabrication and is facilitated by automated test and analysis techniques. Three fabrication processes -- punching, chemical, milling, and electrical discharge machining (EDM) -- were recently evaluated, leading to the replacement of the previously used punching technique with a wire EDM technique. The automated data acquisition system was upgraded, and an interactive data analysis program was developed

  20. Measurement of the yield and tensile strengths of neutron-irradiated and post-irradiation recovered vessel steels with notched specimens

    International Nuclear Information System (INIS)

    Valiente, A.

    1996-01-01

    Tensile circumferentially notched bars are examined as test specimens for measuring the yield and tensile strengths of nuclear pressure vessel steels under several conditions of irradiation and temperature that a vessel can experience during its service life, including recovery post-irradiation treatment. For all the vessel steels, notch geometries and conditions explored, it has been found that notched specimens fail by plastic collapse, and simple formulae have been derived that allow the yield and tensile strengths to be determined from the yielding and plastic collapse load of a notched specimen. Values measured in this way show good agreement with those measured by the standard tensile test method. (orig.)

  1. Tensile testing grips are easily assembled under liquid nitrogen

    Science.gov (United States)

    Skalka, R. J.; Vandergrift, E. F.

    1967-01-01

    Split-screw grips for tensile testing provide uniform loading on the specimen shoulders. Holes in the heads enable the screws and specimen to be threaded as an assembly into a grip body, closely controlled guides and seats afford positive seating, and precision machining of mating surfaces minimizes misalignment effects.

  2. Method for independent strain and temperature measurement in polymeric tensile test specimen using embedded FBG sensors

    DEFF Research Database (Denmark)

    Pereira, Gilmar Ferreira; McGugan, Malcolm; Mikkelsen, Lars Pilgaard

    2016-01-01

    to calculate independently the strain and temperature are presented in the article, together with a measurement resolution study. This multi-parameter measurement method was applied to an epoxy tensile specimen, tested in a unidirectional tensile test machine with a temperature controlled cabinet. A full......A novel method to obtain independent strain and temperature measurements using embedded Fibre Bragg Grating (FBG) in polymeric tensile test specimens is presented in this paper. The FBG strain and temperature cross-sensitivity was decoupled using two single mode FBG sensors, which were embedded...... of temperature, from 40 C to -10 C. The consistency of the expected theoretical results with the calibration procedure and the experimental validation shows that this proposed method is applicable to measure accurate strain and temperature in polymers during static or fatigue tensile testing. Two different...

  3. Monolithic integration of nanoscale tensile specimens and MEMS structures

    International Nuclear Information System (INIS)

    Yilmaz, Mehmet; Kysar, Jeffrey W

    2013-01-01

    Nanoscale materials often have stochastic material properties due to a random distribution of material defects and an insufficient number of defects to ensure a consistent average mechanical response. Current methods to measure the mechanical properties employ MEMS-based actuators. The nanoscale specimens are typically mounted manually onto the load platform, so the boundary conditions have random variations, complicating the experimental measurement of the intrinsic stochasticity of the material properties. Here we show methods for monolithic integration of a nanoscale specimen co-fabricated with the loading platform. The nanoscale specimen is gold with dimensions of ∼40 nm thickness, 350 ± 50 nm width, and 7 μm length and the loading platform is an interdigitated electrode electrostatic actuator. The experiment is performed in a scanning electron microscope and digital image correlation is employed to measure displacements to determine stress and strain. The ultimate tensile strength of the nanocrystalline nanoscale specimen approaches 1 GPa, consistent with measurements made by other nanometer scale sample characterization methods on other material samples at the nanometer scale, as well as gold samples at the nanometer scale. The batch-compatible microfabrication method can be used to create nominally identical nanoscale specimens and boundary conditions for a broad range of materials. (paper)

  4. Tensile Properties of the Deep Transverse Metatarsal Ligament in Hallux Valgus

    Science.gov (United States)

    Abdalbary, Sahar Ahmed; Elshaarawy, Ehab A.A.; Khalid, Bahaa E.A.

    2016-01-01

    Abstract The deep transverse metatarsal ligament (DTML) connects the neighboring 2 metatarsal heads and is one of the stabilizers connecting the lateral sesamoid and second metatarsal head. In this study, we aimed to determine the tensile properties of the DTML in normal specimens and to compare these results with hallux valgus specimens. We hypothesized that the tensile properties of the DTML would be different between the 2 groups of specimens. The DTML in the first interspace was dissected from 12 fresh frozen human cadaveric specimens. Six cadavers had bilateral hallux valgus and the other 6 cadavers had normal feet. The initial length (L0) and cross-sectional area (A0) of the DTML were measured using a digital caliper, and tensile tests with load failure were performed using a material testing machine. There were significant between-groups differences in the initial length (L0) P = 0.009 and cross-sectional area (A0) of the DTML P = 0.007. There were also significant between-groups differences for maximum force (N) P = 0.004, maximum distance (mm) P = 0.005, maximum stress (N/mm2) P = 0.003, and maximum strain (%) P = 0.006. The DTML is an anatomical structure for which the tensile properties differ in hallux valgus. PMID:26937914

  5. Evaluation of impacts of stress triaxiality on plastic deformability of RAFM steel using various types of tensile specimen

    Energy Technology Data Exchange (ETDEWEB)

    Kato, Taichiro, E-mail: kato.taichiro@jaea.go.jp [Japan Atomic Energy Agency, 2-166, Obuchi-omotedate, Rokkasho, Aomori 039-3212 (Japan); Ohata, Mitsuru [Osaka University, 2-1, Yamada-Oka, Suita, Osaka 565-0871 (Japan); Nogami, Shuhei [Tohoku University, 6-6-01-2, Aramaki-aza-Aoba, Aoba-ku, Sendai, Miyagi 980-8579 (Japan); Tanigawa, Hiroyasu [Japan Atomic Energy Agency, 2-166, Obuchi-omotedate, Rokkasho, Aomori 039-3212 (Japan)

    2016-11-01

    Highlights: • The fracture ductility is lower as the stress triaxiality is higher. • Voids of the interrupted RB1 specimen were observed along grain boundaries and expanded parallel to the tensile axis. • Voids of interrupted R0.2 specimen were rounded shape than those of RB1. • The fracture surface of specimens were observed the elongated and the equiaxed dimples. • The decrease of plastic deformability of the notched specimen was caused by the process of voids formation and crack growth due to the effect of plastic constraint of the notch. - Abstract: A case study on a fusion blanket design such as DEMO indicated that there could be some sections with high stress triaxiality, a parameter to evaluate the magnitude of plastic constraint, in the case of plasma disruption or coolant loss accident. Therefore, it is necessary to accurately understand the ductility loss limit of structural material in order to conduct the structural design assessment of the irradiated and embrittled fusion reactor blanket. Tensile tests were conducted by using three kinds of tensile specimen shapes to investigate of the plastic deformability of F82H. From the results, the fracture ductility is lower as the stress triaxiality is higher. Voids of the interrupted RB1 specimen were observed along grain boundaries and expanded parallel to the tensile axis. That of interrupted R0.2 specimen was rounded shape compared with those of RB1. The fracture surface of RB1 and R0.2 specimens were observed the elongated dimples and the equiaxed dimples without so much elongation, respectively. It is considered that the decrease of plastic deformability for the notched specimen was caused by the process of voids formation and crack growth due to the effect of plastic constraint of the notch.

  6. Feasibility Study of Laser Cutting for Fabrication of Tensile Specimen

    International Nuclear Information System (INIS)

    Jin, Y. G.; Baik, S. J.; Kim, G. S.; Heo, G. S.; Yoo, B. O.; Ahn, S. B.; Chun, Y. B.

    2015-01-01

    The specimen fabrication technique was established to machine the specimen from the irradiated materials. The wire cut EDM(electric discharge machine) was modified to fabricate the mechanical testing specimens from irradiated components and fuel claddings. The oxide layer removal system was also developed because the oxide layer on the surface of the irradiated components and claddings interrupted the applying the electric current during the processing. However, zirconium oxide is protective against further corrosion as well as beneficial to mechanical strength for the tensile deformation of the cladding. Thus, it is important to fabricate the irradiated specimens without removal of oxide layer on the surface of the irradiated structural components and claddings. In the present study, laser cutting system was introduced to fabricate the various mechanical testing specimens from the unirradiated fuel cladding and the feasibility of the laser cutting system was studied for the fabrication of various types of irradiated specimens in a hot cell at IMEF (Irradiated Materials Examination Facility) of KAERI. Laser beam machining system was introduced to fabricate the various mechanical testing specimens from the unirradiated fuel cladding and the dimensions were compared for the feasibility of the laser cutting system. The effect of surface oxide layer was also investigated for machining process of the zircaloy-4 fuel cladding and it was found that laser beam machining could be a useful tool to fabricate the specimens with surface oxide layer

  7. Feasibility Study of Laser Cutting for Fabrication of Tensile Specimen

    Energy Technology Data Exchange (ETDEWEB)

    Jin, Y. G.; Baik, S. J.; Kim, G. S.; Heo, G. S.; Yoo, B. O.; Ahn, S. B.; Chun, Y. B. [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2015-05-15

    The specimen fabrication technique was established to machine the specimen from the irradiated materials. The wire cut EDM(electric discharge machine) was modified to fabricate the mechanical testing specimens from irradiated components and fuel claddings. The oxide layer removal system was also developed because the oxide layer on the surface of the irradiated components and claddings interrupted the applying the electric current during the processing. However, zirconium oxide is protective against further corrosion as well as beneficial to mechanical strength for the tensile deformation of the cladding. Thus, it is important to fabricate the irradiated specimens without removal of oxide layer on the surface of the irradiated structural components and claddings. In the present study, laser cutting system was introduced to fabricate the various mechanical testing specimens from the unirradiated fuel cladding and the feasibility of the laser cutting system was studied for the fabrication of various types of irradiated specimens in a hot cell at IMEF (Irradiated Materials Examination Facility) of KAERI. Laser beam machining system was introduced to fabricate the various mechanical testing specimens from the unirradiated fuel cladding and the dimensions were compared for the feasibility of the laser cutting system. The effect of surface oxide layer was also investigated for machining process of the zircaloy-4 fuel cladding and it was found that laser beam machining could be a useful tool to fabricate the specimens with surface oxide layer.

  8. Finite element analysis of steel fiber-reinforced concrete (SFRC): validation of experimental tensile capacity of dog-bone specimens

    Science.gov (United States)

    Islam, Md. Mashfiqul; Chowdhury, Md. Arman; Sayeed, Md. Abu; Hossain, Elsha Al; Ahmed, Sheikh Saleh; Siddique, Ashfia

    2014-09-01

    Finite element analyses are conducted to model the tensile capacity of steel fiber-reinforced concrete (SFRC). For this purpose dog-bone specimens are casted and tested under direct and uniaxial tension. Two types of aggregates (brick and stone) are used to cast the SFRC and plain concrete. The fiber volume ratio is maintained 1.5 %. Total 8 numbers of dog-bone specimens are made and tested in a 1000-kN capacity digital universal testing machine (UTM). The strain data are gathered employing digital image correlation technique from high-definition images and high-speed video clips. Then, the strain data are synthesized with the load data obtained from the load cell of the UTM. The tensile capacity enhancement is found 182-253 % compared to control specimen to brick SFRC and in case of stone SFRC the enhancement is 157-268 %. Fibers are found to enhance the tensile capacity as well as ductile properties of concrete that ensures to prevent sudden brittle failure. The dog-bone specimens are modeled in the ANSYS 10.0 finite element platform and analyzed to model the tensile capacity of brick and stone SFRC. The SOLID65 element is used to model the SFRC as well as plain concretes by optimizing the Poisson's ratio, modulus of elasticity, tensile strength and stress-strain relationships and also failure pattern as well as failure locations. This research provides information of the tensile capacity enhancement of SFRC made of both brick and stone which will be helpful for the construction industry of Bangladesh to introduce this engineering material in earthquake design. Last of all, the finite element outputs are found to hold good agreement with the experimental tensile capacity which validates the FE modeling.

  9. In-situ measurement of the strain distribution in a tensile specimen by using a digital speckle pattern interferometer

    International Nuclear Information System (INIS)

    Park, Seung-Kyu; Baik, Sung-Hoon; Cha, Hyung-Ki; Kim, Young-Suk; Cheong, Yong-Moo

    2010-01-01

    Less sensitivity to environmental vibrations is essential for industrial applications of a digital speckle pattern interferometer (DSPI) to measure micro deformations. In this paper, a robust DSPI using single fringe to mechanical vibrations is designed for measuring the strain distribution of a tensile specimen. This system adopts a noise-immune signal processing algorithm to acquire a 3D strain distribution image. To acquire an accurate strain distribution for a tensile-specimen, locally-averaged and directionally-oriented filters operating in the frequency domain are used. This system uses a path-independent least-squares phase-unwrapping algorithm to acquire the 3D shape of the strain distribution. As for the initial experiments to measure the strain distribution of a tensile specimen in a vibration field, this system demonstrated a feasibility for industrial applications by providing reliable strain data.

  10. Finite Element Modeling of Compressive and Splitting Tensile Behavior of Plain Concrete and Steel Fiber Reinforced Concrete Cylinder Specimens

    Directory of Open Access Journals (Sweden)

    Md. Arman Chowdhury

    2016-01-01

    Full Text Available Plain concrete and steel fiber reinforced concrete (SFRC cylinder specimens are modeled in the finite element (FE platform of ANSYS 10.0 and validated with the experimental results and failure patterns. Experimental investigations are conducted to study the increase in compressive and tensile capacity of cylindrical specimens made of stone and brick concrete and SFRC. Satisfactory compressive and tensile capacity improvement is observed by adding steel fibers of 1.5% volumetric ratio. A total of 8 numbers of cylinder specimens are cast and tested in 1000 kN capacity digital universal testing machine (UTM and also modeled in ANSYS. The enhancement of compressive strength and splitting tensile strength of SFRC specimen is achieved up to 17% and 146%, respectively, compared to respective plain concrete specimen. Results gathered from finite element analyses are validated with the experimental test results by identifying as well as optimizing the controlling parameters to make FE models. Modulus of elasticity, Poisson’s ratio, stress-strain behavior, tensile strength, density, and shear transfer coefficients for open and closed cracks are found to be the main governing parameters for successful model of plain concrete and SFRC in FE platform. After proper evaluation and logical optimization of these parameters by extensive analyses, finite element (FE models showed a good correlation with the experimental results.

  11. Stress-deformed state of cylindrical specimens during indirect tensile strength testing

    Directory of Open Access Journals (Sweden)

    Levan Japaridze

    2015-10-01

    Full Text Available In this study, the interaction between cylindrical specimen made of homogeneous, isotropic, and linearly elastic material and loading jaws of any curvature is considered in the Brazilian test. It is assumed that the specimen is diametrically compressed by elliptic normal contact stresses. The frictional contact stresses between the specimen and platens are neglected. The analytical solution starts from the contact problem of the loading jaws of any curvature and cylindrical specimen. The contact width, corresponding loading angle (2θ0, and elliptical stresses obtained through solution of the contact problems are used as boundary conditions for a cylindrical specimen. The problem of the theory of elasticity for a cylinder is solved using Muskhelishvili's method. In this method, the displacements and stresses are represented in terms of two analytical functions of a complex variable. In the main approaches, the nonlinear interaction between the loading bearing blocks and the specimen as well as the curvature of their surfaces and the elastic parameters of their materials are taken into account. Numerical examples are solved using MATLAB to demonstrate the influence of deformability, curvature of the specimen and platens on the distribution of the normal contact stresses as well as on the tensile and compressive stresses acting across the loaded diameter. Derived equations also allow calculating the modulus of elasticity, total deformation modulus and creep parameters of the specimen material based on the experimental data of radial contraction of the specimen.

  12. Tensile Properties of the Deep Transverse Metatarsal Ligament in Hallux Valgus: A CONSORT-Compliant Article.

    Science.gov (United States)

    Abdalbary, Sahar Ahmed; Elshaarawy, Ehab A A; Khalid, Bahaa E A

    2016-02-01

    The deep transverse metatarsal ligament (DTML) connects the neighboring2 metatarsal heads and is one of the stabilizers connecting the lateral sesamoid and second metatarsal head. In this study, we aimed to determine the tensile properties of the DTML in normal specimens and to compare these results with hallux valgus specimens. We hypothesized that the tensile properties of the DTML would be different between the 2 groups of specimens.The DTML in the first interspace was dissected from 12 fresh frozen human cadaveric specimens. Six cadavers had bilateral hallux valgus and the other 6 cadavers had normal feet. The initial length (L0) and cross-sectional area (A0) of the DTML were measured using a digital caliper, and tensile tests with load failure were performed using a material testing machine.There were significant between-groups differences in the initial length (L0) P = 0.009 and cross-sectional area (A0) of the DTML P = 0.007. There were also significant between-groups differences for maximum force (N) P = 0.004, maximum distance (mm) P = 0.005, maximum stress (N/mm) P = 0.003, and maximum strain (%) P = 0.006.The DTML is an anatomical structure for which the tensile properties differ in hallux valgus.

  13. Specimen alignment in an axial tensile test of thin films using direct imaging and its influence on the mechanical properties of BeCu

    International Nuclear Information System (INIS)

    Kang, Dong-Joong; Park, Jun-Hyub; Shin, Myung-Soo; Ha, Jong-Eun; Lee, Hak-Joo

    2010-01-01

    This paper proposes a new system for verification of the alignment of loading fixtures and test specimens during tensile testing of thin film with a micrometer size through direct imaging. The novel and reliable image recognition system to evaluate the misalignment between the load train and the specimen axes during tensile test of thin film was developed using digital image processing technology with CCD. The decision of whether alignment of the tensile specimen is acceptable or not is based on a probabilistic analysis through the edge feature extraction of digital imaging. In order to verify the performance of the proposed system and investigate the effect of the misalignment of the specimen on tensile properties, the tensile tests were performed as displacement control in air and at room temperature for metal thin film, the beryllium copper (BeCu) alloys. In the case of the metal thin films, bending stresses caused by misalignment are insignificant because the films are easily bent during tensile tests to eliminate the bending stresses. And it was observed that little effects and scatters on tensile properties occur by stress gradient caused by twisting at in-plane misalignment, and the effects and scatters on tensile properties are insignificant at out-of-plane misalignment, in the case of the BeCu thin film.

  14. Finite Element Modeling of Compressive and Splitting Tensile Behavior of Plain Concrete and Steel Fiber Reinforced Concrete Cylinder Specimens

    OpenAIRE

    Chowdhury, Md. Arman; Islam, Md. Mashfiqul; Ibna Zahid, Zubayer

    2016-01-01

    Plain concrete and steel fiber reinforced concrete (SFRC) cylinder specimens are modeled in the finite element (FE) platform of ANSYS 10.0 and validated with the experimental results and failure patterns. Experimental investigations are conducted to study the increase in compressive and tensile capacity of cylindrical specimens made of stone and brick concrete and SFRC. Satisfactory compressive and tensile capacity improvement is observed by adding steel fibers of 1.5% volumetric ratio. A tot...

  15. Fractography evaluation of impact and tensile specimens from the HFBR [High Flux Beam Reactor

    International Nuclear Information System (INIS)

    Czajkowski, C.J.

    1989-10-01

    The Materials Technology Group of the Department of Nuclear Energy (DNE) at Brookhaven National Laboratory (BNL) has performed a fractographic examination of neutron irradiated and unirradiated tensile and Charpy ''V'' notch specimens. The evaluation was carried out using a scanning electron microscope (SEM) to evaluate the fracture mode. Photomicrographs were then evaluated to determine the extent of ductility present on the fracture surfaces of the unirradiated specimens. Ductility area measurements ranged from 4.6--9.5% on typical photomicrographs examined. 12 figs

  16. Effect of holes on the room temperature tensile behaviors of thin wall specimens with (210) side surface of Ni-base single crystal superalloy

    Energy Technology Data Exchange (ETDEWEB)

    Zhou, Z.J.; Liu, T.; Pu, S. [Superalloys Division, Institute of Metal Research, Chinese Academy of Sciences, No. 72, Wenhua Road, Shenyang 110016 (China); Xu, H. [Materials Fatigue and Fracture Division, Institute of Metal Research, Chinese Academy of Sciences, No. 72, Wenhua Road, Shenyang 110016 (China); Wang, L., E-mail: wangli@imr.ac.cn [Superalloys Division, Institute of Metal Research, Chinese Academy of Sciences, No. 72, Wenhua Road, Shenyang 110016 (China); Lou, L.H. [Superalloys Division, Institute of Metal Research, Chinese Academy of Sciences, No. 72, Wenhua Road, Shenyang 110016 (China)

    2015-10-25

    Tensile properties of Ni-base single crystal superalloy plate specimens with and without a hole at room temperature were studied in the present paper. During the testing process, an ARAMIS system based on the digital image correlation technique and in-situ scanning electron microscopy were employed to in-situ observe the strain distribution and slip traces development on the sample surfaces. It was demonstrated that the yield stress was decreased with the appearance of a hole due to the stress concentration. The results were analyzed based on the stress and strain states of specimens and the slip traces development observed on specimen surfaces. - Graphical abstract: The strain distribution for samples without and with a hole, respectively. - Highlights: • Tensile tests of plate specimens without and with a hole were performed. • Surface strain fields were in-situ observed by ARAMIS system. • Slip traces development on sample surfaces was in-situ observed by SEM. • The hole deteriorated both the tensile strength and elongation of the samples. • Tensile strength of specimens without and with a hole was discussed respectively.

  17. Fracture toughness evaluation using circumferential notched tensile specimens by the tensile test and ANSYS software

    Energy Technology Data Exchange (ETDEWEB)

    Meydanlik, N. [Mechanical Engineering Department, Trakya University, Edirne (Turkey)

    2013-07-01

    Fracture toughness (K{sub Ic} ) is the most important parameter that defines mechanical behaviour of the materials using machine design. Since, fracture tests are both difficult and time consuming, the researchers have been investigating for the easier evaluation of K{sub Ic} for many years. In this work; K{sub Ic} values have been obtained by using ANSYS software based on the experimental values evaluated in the previous studies. It was shown that there is no significant difference between the experimental ones and the ones obtained by ANSYS. This procedure can provide an important advantage on obtaining of the K{sub IC} values. Key words: Fracture toughness (K{sub Ic} ), circumferential notched tensile specimens, ANSYS.

  18. Shear Bond Strength of Orthodontic Brackets and Disinclusion Buttons: Effect of Water and Saliva Contamination

    OpenAIRE

    Sfondrini, Maria Francesca; Fraticelli, Danilo; Gandini, Paola; Scribante, Andrea

    2013-01-01

    Purpose. The aim of this study was to assess the effect of water and saliva contamination on the shear bond strength and failure site of orthodontic brackets and lingual buttons. Materials and Methods. 120 bovine permanent mandibular incisors were randomly divided into 6 groups of 20 specimens each. Both orthodontic brackets and disinclusion buttons were tested under three different enamel surface conditions: (a) dry, (b) water contamination, and (c) saliva contamination. Brackets and buttons...

  19. High-Tensile Strength Tape Versus High-Tensile Strength Suture: A Biomechanical Study.

    Science.gov (United States)

    Gnandt, Ryan J; Smith, Jennifer L; Nguyen-Ta, Kim; McDonald, Lucas; LeClere, Lance E

    2016-02-01

    To determine which suture design, high-tensile strength tape or high-tensile strength suture, performed better at securing human tissue across 4 selected suture techniques commonly used in tendinous repair, by comparing the total load at failure measured during a fixed-rate longitudinal single load to failure using a biomechanical testing machine. Matched sets of tendon specimens with bony attachments were dissected from 15 human cadaveric lower extremities in a manner allowing for direct comparison testing. With the use of selected techniques (simple Mason-Allen in the patellar tendon specimens, whip stitch in the quadriceps tendon specimens, and Krackow stitch in the Achilles tendon specimens), 1 sample of each set was sutured with a 2-mm braided, nonabsorbable, high-tensile strength tape and the other with a No. 2 braided, nonabsorbable, high-tensile strength suture. A total of 120 specimens were tested. Each model was loaded to failure at a fixed longitudinal traction rate of 100 mm/min. The maximum load and failure method were recorded. In the whip stitch and the Krackow-stitch models, the high-tensile strength tape had a significantly greater mean load at failure with a difference of 181 N (P = .001) and 94 N (P = .015) respectively. No significant difference was found in the Mason-Allen and simple stitch models. Pull-through remained the most common method of failure at an overall rate of 56.7% (suture = 55%; tape = 58.3%). In biomechanical testing during a single load to failure, high-tensile strength tape performs more favorably than high-tensile strength suture, with a greater mean load to failure, in both the whip- and Krackow-stitch models. Although suture pull-through remains the most common method of failure, high-tensile strength tape requires a significantly greater load to pull-through in a whip-stitch and Krakow-stitch model. The biomechanical data obtained in the current study indicates that high-tensile strength tape may provide better repair

  20. Acoustic emission during tensile deformation and fracture of nuclear grade AISI type 304 stainless steel specimens with notches

    International Nuclear Information System (INIS)

    Mukhopadhyay, C.K.; Jayakumar, T.; Baldev Raj

    1996-01-01

    Acoustic emission generated during tensile deformation and fracture of nuclear grade AISI type 304 stainless steel specimens with notches has been studied. The extent of acoustic activity generated depends on notch tip severity, notch tip blunting and tearing of the notches. The equation N=AK m applied to the acoustic emission data of the notched specimens has shown good correlation. Acoustic emission technique can be used to estimate the size of an unknown notch. (author)

  1. Size effect studies on smooth tensile specimens at room temperature and 400 oC

    International Nuclear Information System (INIS)

    Krompholz, K.; Kamber, J.; Groth, E.; Kalkhof, D.

    2000-06-01

    One of the objectives of the REVISA project (REactor Vessel Integrity in Severe Accidents) is to assess the size effect related to deformation and failure models as well as material data under quasistatic and dynamic conditions in homogeneous and non-homogeneous states of strain. For these investigations the reactor pressure vessel material 20 MnMoNi 55 was selected. It was subjected to a size effect study on smooth scaled tensile specimens of three sizes. Two strain rates (2*10 -5 /s and 10 -3 /s) and two temperatures (room temperature and 400 o C) were selected. The investigations are aimed at a support for a gradient plasticity approach to size effects. Test on the small specimens (diameters 3 and 9 mm) were performed at an electromechanical test machine, while the large specimens (diameter 30 mm) had to be tested at a servohydraulical closed loop test machine with a force capacity of 1000 kN

  2. Effect of gap distance on tensile strength of preceramic base metal solder joints.

    Science.gov (United States)

    Fattahi, Farnaz; Motamedi, Milad

    2011-01-01

    In order to fabricate prostheses with high accuracy and durability, soldering techniques have been introduced to clinical dentistry. However, these prostheses always fail at their solder joints. The purpose of this study was to evaluate the effect of gap distance on the tensile strength of base metal solder joints. Based on ADA/ISO 9693 specifications for tensile test, 40 specimens were fabricated from a Ni-Cr alloy and cut at the midpoint of 3-mm diameter bar and placed at desired positions by a specially designed device. The specimens were divided into four groups of 10 samples according to the desired solder gap distance: Group1: 0.1mm; Group2: 0.25mm; Group3: 0.5mm; and Group4: 0.75mm. After soldering, specimens were tested for tensile strength by a universal testing machine at a cross-head speed of 0.5mm/min with a preload of 10N. The mean tensile strength values of the groups were 162, 307.8, 206.1 and 336.7 MPa, respectively. The group with 0.75-mm gap had the highest and the group with 0.1-mm gap had the lowest tensile strength. Bonferroni test showed that Group1 and Group4 had statistically different values (P=0.023), but the differences between other groups were not sig-nificant at a significance level of 0.05. There was no direct relationship between increasing soldering gap distance and tensile strength of the solder joints.

  3. Determination of necking time in tensile test specimens, under high-temperature creep conditions, subjected to distribution of stresses over the cross-section

    Science.gov (United States)

    Lokoshchenko, A.; Teraud, W.

    2018-04-01

    The work describes an experimental research of creep of cylindrical tensile test specimens made of aluminum alloy D16T at a constant temperature of 400°C. The issue to be examined was the necking at different values of initial tensile stresses. The use of a developed noncontacting measuring system allowed us to see variations in the specimen shape and to estimate the true stress in various times. Based on the obtained experimental data, several criteria were proposed for describing the point of time at which the necking occurs (necking point). Calculations were carried out at various values of the parameters in these criteria. The relative interval of deformation time in which the test specimen is uniformly stretched was also determined.

  4. In Situ Radiography During Tensile Tests

    Science.gov (United States)

    Baaklini, George Y.; Bhatt, Ramakrishna T.

    1994-01-01

    Laboratory system for testing specimens of metal-, ceramic-, and intermetallic-matrix composite materials incorporates both electromechanical tensile-testing subsystem and either of two imaging subsystems that take x-ray photographs of specimens before, during, and after tensile tests. Used to test specimens of reaction-bonded silicon nitride reinforced with silicon carbide fibers (SiC/RBSN) considered for high-temperature service in advanced aircraft turbine engines. Provides data on effects of preexisting flaws (e.g., high-density impurities and local variations of density) on fracture behavior. Accumulated internal damage monitored during loading. X-ray source illuminates specimen in load frame while specimen is pulled. X-ray images on film correlated with stress-vs.-strain data from tensile test.

  5. Void coalescence and fracture behavior of notched and un-notched tensile tested specimens in fine grain dual phase steel

    Energy Technology Data Exchange (ETDEWEB)

    Saeidi, N., E-mail: navidsae@gmail.com [Department of Materials Engineering, Isfahan University of Technology, Isfahan 84156-83111 (Iran, Islamic Republic of); Ashrafizadeh, F.; Niroumand, B. [Department of Materials Engineering, Isfahan University of Technology, Isfahan 84156-83111 (Iran, Islamic Republic of); Forouzan, M.R.; Mohseni mofidi, S. [Department of Mechanical Engineering, Isfahan University of Technology, Isfahan 84156-83111 (Iran, Islamic Republic of); Barlat, F. [Materials Mechanics Laboratory (MML), Graduate Institute of Ferrous Technology (GIFT), Pohang University of Science and Technology POSTECH, San 31 Hyoja-dong, Nam-gu, Pohang, Gyeongbuk 790-784 (Korea, Republic of)

    2015-09-17

    Due to growing global concern about the environmental issues, steel developers have been forced by automobile makers to produce more efficient steel grades with high strength to weight ratios along with high crashworthiness performance. In order to find deficiencies of the existing steels and develop superior steel products, detailed understanding of deformation and damage behavior in the existing steels is needed. In the present research, deformation and damage evolution during room temperature uniaxial tensile test of a modern high strength Dual Phase Steel, i.e. DP780, were studied. Detailed scanning electron microscopy (SEM) examination of the microstructures of notched and un-notched tensile fractured specimens revealed that in notched specimen, plastic deformation was concentrated more within the notched region. Therefore, much higher reduction in thickness with a high reduction gradient occurred in this region, In the un-notched specimen, however, plastic deformation was more uniformly distributed in larger parts of the gauge length, and therefore, thickness reduction happened with a lower gradient. Although geometric notch on the specimen did not change the void nucleation and growth mechanisms, the kinetics of these phenomena was influenced. On the other hand, voids linkage mechanism tended to change from void coalescence in the un-notched specimen to void sheeting in the notched specimen. Moreover, three different models developed by Brown & Embury (BM), Thomason and Pardoen were employed to predict the final fracture strain. It was revealed that, BM model showed much more accurate predictions for the studied DP steel in comparison with those of Thomason and Pardoens’ models.

  6. Void coalescence and fracture behavior of notched and un-notched tensile tested specimens in fine grain dual phase steel

    International Nuclear Information System (INIS)

    Saeidi, N.; Ashrafizadeh, F.; Niroumand, B.; Forouzan, M.R.; Mohseni mofidi, S.; Barlat, F.

    2015-01-01

    Due to growing global concern about the environmental issues, steel developers have been forced by automobile makers to produce more efficient steel grades with high strength to weight ratios along with high crashworthiness performance. In order to find deficiencies of the existing steels and develop superior steel products, detailed understanding of deformation and damage behavior in the existing steels is needed. In the present research, deformation and damage evolution during room temperature uniaxial tensile test of a modern high strength Dual Phase Steel, i.e. DP780, were studied. Detailed scanning electron microscopy (SEM) examination of the microstructures of notched and un-notched tensile fractured specimens revealed that in notched specimen, plastic deformation was concentrated more within the notched region. Therefore, much higher reduction in thickness with a high reduction gradient occurred in this region, In the un-notched specimen, however, plastic deformation was more uniformly distributed in larger parts of the gauge length, and therefore, thickness reduction happened with a lower gradient. Although geometric notch on the specimen did not change the void nucleation and growth mechanisms, the kinetics of these phenomena was influenced. On the other hand, voids linkage mechanism tended to change from void coalescence in the un-notched specimen to void sheeting in the notched specimen. Moreover, three different models developed by Brown & Embury (BM), Thomason and Pardoen were employed to predict the final fracture strain. It was revealed that, BM model showed much more accurate predictions for the studied DP steel in comparison with those of Thomason and Pardoens’ models

  7. Effect of blood contamination on shear bond strength of orthodontic brackets and disinclusion buttons.

    Science.gov (United States)

    Sfondrini, Maria Francesca; Gatti, Sara; Scribante, Andrea

    2011-07-01

    Our aim was to assess the effect of blood contamination on the shear bonding strength and sites of failure of orthodontic brackets and bondable buttons. We randomly divided 160 bovine permanent mandibular incisors into 8 groups of 20 specimens each. Both orthodontic brackets (Step brackets, Leone, Sesto Fiorentino, Italy) and bondable buttons (Flat orthodontic buttons, Leone, Sesto Fiorentino, Italy) were tested on four different enamel surfaces: dry; contamination with blood before priming; after priming; and before and after priming. Brackets and buttons were bonded to the teeth and subsequently tested using a Instron universal testing machine. Shear bonding strength and the rate of adhesive failures were recorded. Data were analysed using the analysis of variance (ANOVA), Scheffè tests, and the chi-square test. Uncontaminated enamel surfaces showed the highest bonding strengths for both brackets and buttons. When they were contaminated with blood, orthodontic brackets had significantly lower shear strengths than bondable buttons (P=0.0001). There were significant differences in sites of failure among the groups for the various enamel surfaces (P=0.001). Contamination of enamel by blood during bonding lowers the strength of the bond, more so with orthodontic brackets than with bondable buttons. Copyright © 2010 The British Association of Oral and Maxillofacial Surgeons. Published by Elsevier Ltd. All rights reserved.

  8. Shear bond strength of orthodontic brackets and disinclusion buttons: effect of water and saliva contamination.

    Science.gov (United States)

    Sfondrini, Maria Francesca; Fraticelli, Danilo; Gandini, Paola; Scribante, Andrea

    2013-01-01

    The aim of this study was to assess the effect of water and saliva contamination on the shear bond strength and failure site of orthodontic brackets and lingual buttons. 120 bovine permanent mandibular incisors were randomly divided into 6 groups of 20 specimens each. Both orthodontic brackets and disinclusion buttons were tested under three different enamel surface conditions: (a) dry, (b) water contamination, and (c) saliva contamination. Brackets and buttons were bonded to the teeth and subsequently tested using a Instron universal testing machine. Shear bond strength values and adhesive failure rate were recorded. Statistical analysis was performed using ANOVA and Tukey tests (strength values) and Chi squared test (ARI Scores). Noncontaminated enamel surfaces showed the highest bond strengths for both brackets and buttons. Under water and saliva contamination orthodontic brackets groups showed significantly lower shear strengths than disinclusion buttons groups. Significant differences in debond locations were found among the groups under the various enamel surface conditions. Water and saliva contamination of enamel during the bonding procedure lowers bond strength values, more with orthodontic brackets than with disinclusion buttons.

  9. Size effect studies on smooth tensile specimens at room temperature and 400 {sup o}C

    Energy Technology Data Exchange (ETDEWEB)

    Krompholz, K.; Kamber, J.; Groth, E.; Kalkhof, D

    2000-06-15

    One of the objectives of the REVISA project (REactor Vessel Integrity in Severe Accidents) is to assess the size effect related to deformation and failure models as well as material data under quasistatic and dynamic conditions in homogeneous and non-homogeneous states of strain. For these investigations the reactor pressure vessel material 20 MnMoNi 55 was selected. It was subjected to a size effect study on smooth scaled tensile specimens of three sizes. Two strain rates (2*10{sup -5}/s and 10{sup -3}/s) and two temperatures (room temperature and 400 {sup o}C) were selected. The investigations are aimed at a support for a gradient plasticity approach to size effects. Test on the small specimens (diameters 3 and 9 mm) were performed at an electromechanical test machine, while the large specimens (diameter 30 mm) had to be tested at a servohydraulical closed loop test machine with a force capacity of 1000 kN.

  10. Button fixation technique for Achilles tendon reinsertion: a biomechanical study.

    Science.gov (United States)

    Awogni, David; Chauvette, Guillaume; Lemieux, Marie-Line; Balg, Frédéric; Langelier, Ève; Allard, Jean-Pascal

    2014-01-01

    Chronic insertional tendinopathy of the Achilles tendon is a frequent and disabling pathologic entity. Operative treatment is indicated for patients for whom nonoperative management has failed. The treatment can consist of the complete detachment of the tendon insertion and extensive debridement. We biomechanically tested a new operative technique that uses buttons for fixation of the Achilles tendon insertion on the posterior calcaneal tuberosity and compared it with 2 standard bone anchor techniques. A total of 40 fresh-frozen cadaver specimens were used to compare 3 fixation techniques for reinserting the Achilles tendon: single row anchors, double row anchors, and buttons. The ultimate loads and failure mechanisms were recorded. The button assembly (median load 764 N, range 713 to 888) yielded a median fixation strength equal to 202% (range 137% to 251%) of that obtained with the double row anchors (median load 412 N, range 301 to 571) and 255% (range 213% to 317%) of that obtained with the single row anchors (median load 338 N, range 241 to 433N). The most common failure mechanisms were suture breakage with the buttons (55%) and pull out of the implant with the double row (70%) and single row (85%) anchors. The results of the present biomechanical cadaver study have shown that Achilles tendon reinsertion fixation using the button technique provides superior pull out strength than the bone anchors tested. Copyright © 2014 American College of Foot and Ankle Surgeons. Published by Elsevier Inc. All rights reserved.

  11. High strain rate mechanical response of buttress-grooved tensile specimens which have undergone environmental exposure

    International Nuclear Information System (INIS)

    Weirick, L.J.

    1976-07-01

    The purpose of the corrosion compatibility program was to identify the effect of corrosion on the mechanical performance of the buttress-grooved section of the 105-mm penetrator, a section which must sustain a load during launch. It is important that the environment not deteriorate the mechanical integrity of these grooves during long-term storage. Both coated and uncoated test specimens which simulate both geometrical shape and residual stress patterns were exposed to corrosive environments of moist air, distilled water, and salt water. Some of these tests also incorporated the galvanic coupling caused by the aluminum sabot. After exposure to the corrosive environments, the specimens were pulled on a high strain rate tensile machine which simulated launch conditions. Results show that the galvanic coupling due to the aluminum sabot caused no deterioration of mechanical properties. Results do indicate that the coating applied caused a significant reduction in the fracture load. There was a dichotomy in the results as affected by the environment. Uncoated test specimens showed no change in fracture load with increasing severity of corrosion environment, whereas the coated specimens indicated a trend of decreasing load-bearing ability with increasing corrosion

  12. Virtual button interface

    Science.gov (United States)

    Jones, J.S.

    1999-01-12

    An apparatus and method of issuing commands to a computer by a user interfacing with a virtual reality environment are disclosed. To issue a command, the user directs gaze at a virtual button within the virtual reality environment, causing a perceptible change in the virtual button, which then sends a command corresponding to the virtual button to the computer, optionally after a confirming action is performed by the user, such as depressing a thumb switch. 4 figs.

  13. Analysis on the stress corrosion crack inception based on pit shape and size of the FV520B tensile specimen

    Science.gov (United States)

    Xiang, Longhao; Pan, Juyi; Chen, Songying

    2018-06-01

    The influence of pit shape and size on local stress concentration in the tensile specimen and the stress corrosion cracks inception was studied by employing the element remove technique. The maximum stress located in the bottom of pit on FV520B tensile specimen. The location of maximum strain was near the mouth of the pit or the shoulder and plastic strain existed in this region. Stress concentration factor and plastic deformation on four different geometrical shape pits of hemisphere, semi-ellipsoid, bullet and butterfly were numerically investigated, respectively. The simulation results showed that butterfly pit got the biggest stress concentration factor. The plastic strain rate during pit growth was in the sensitivity range of stress corrosion cracks inception, indicating that stress corrosion cracks were more likely to nucleate near the pit tip or the shoulder.

  14. Shear Bond Strength of Orthodontic Brackets and Disinclusion Buttons: Effect of Water and Saliva Contamination

    Science.gov (United States)

    Sfondrini, Maria Francesca; Fraticelli, Danilo; Gandini, Paola

    2013-01-01

    Purpose. The aim of this study was to assess the effect of water and saliva contamination on the shear bond strength and failure site of orthodontic brackets and lingual buttons. Materials and Methods. 120 bovine permanent mandibular incisors were randomly divided into 6 groups of 20 specimens each. Both orthodontic brackets and disinclusion buttons were tested under three different enamel surface conditions: (a) dry, (b) water contamination, and (c) saliva contamination. Brackets and buttons were bonded to the teeth and subsequently tested using a Instron universal testing machine. Shear bond strength values and adhesive failure rate were recorded. Statistical analysis was performed using ANOVA and Tukey tests (strength values) and Chi squared test (ARI Scores). Results. Noncontaminated enamel surfaces showed the highest bond strengths for both brackets and buttons. Under water and saliva contamination orthodontic brackets groups showed significantly lower shear strengths than disinclusion buttons groups. Significant differences in debond locations were found among the groups under the various enamel surface conditions. Conclusions. Water and saliva contamination of enamel during the bonding procedure lowers bond strength values, more with orthodontic brackets than with disinclusion buttons. PMID:23762825

  15. Shear Bond Strength of Orthodontic Brackets and Disinclusion Buttons: Effect of Water and Saliva Contamination

    Directory of Open Access Journals (Sweden)

    Maria Francesca Sfondrini

    2013-01-01

    Full Text Available Purpose. The aim of this study was to assess the effect of water and saliva contamination on the shear bond strength and failure site of orthodontic brackets and lingual buttons. Materials and Methods. 120 bovine permanent mandibular incisors were randomly divided into 6 groups of 20 specimens each. Both orthodontic brackets and disinclusion buttons were tested under three different enamel surface conditions: (a dry, (b water contamination, and (c saliva contamination. Brackets and buttons were bonded to the teeth and subsequently tested using a Instron universal testing machine. Shear bond strength values and adhesive failure rate were recorded. Statistical analysis was performed using ANOVA and Tukey tests (strength values and Chi squared test (ARI Scores. Results. Noncontaminated enamel surfaces showed the highest bond strengths for both brackets and buttons. Under water and saliva contamination orthodontic brackets groups showed significantly lower shear strengths than disinclusion buttons groups. Significant differences in debond locations were found among the groups under the various enamel surface conditions. Conclusions. Water and saliva contamination of enamel during the bonding procedure lowers bond strength values, more with orthodontic brackets than with disinclusion buttons.

  16. An inverse method based on finite element model to derive the plastic flow properties from non-standard tensile specimens of Eurofer97 steel

    Directory of Open Access Journals (Sweden)

    S. Knitel

    2016-12-01

    Full Text Available A new inverse method was developed to derive the plastic flow properties of non-standard disk tensile specimens, which were so designed to fit irradiation rods used for spallation irradiations in SINQ (Schweizer Spallations Neutronen Quelle target at Paul Scherrer Institute. The inverse method, which makes use of MATLAB and the finite element code ABAQUS, is based upon the reconstruction of the load-displacement curve by a succession of connected small linear segments. To do so, the experimental engineering stress/strain curve is divided into an elastic and a plastic section, and the plastic section is further divided into small segments. Each segment is then used to determine an associated pair of true stress/plastic strain values, representing the constitutive behavior. The main advantage of the method is that it does not rely on a hypothetic analytical expression of the constitutive behavior. To account for the stress/strain gradients that develop in the non-standard specimen, the stress and strain were weighted over the volume of the deforming elements. The method was validated with tensile tests carried out at room temperature on non-standard flat disk tensile specimens as well as on standard cylindrical specimens made of the reduced-activation tempered martensitic steel Eurofer97. While both specimen geometries presented a significant difference in terms of deformation localization during necking, the same true stress/strain curve was deduced from the inverse method. The potential and usefulness of the inverse method is outlined for irradiated materials that suffer from a large uniform elongation reduction.

  17. Standard practice for verification of testing frame and specimen alignment under tensile and compressive axial force application

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2005-01-01

    1.1 Included in this practice are methods covering the determination of the amount of bending that occurs during the application of tensile and compressive forces to notched and unnotched test specimens in the elastic range and to plastic strains less than 0.002. These methods are particularly applicable to the force application rates normally used for tension testing, creep testing, and uniaxial fatigue testing.

  18. Standard practice for verification of testing frame and specimen alignment under tensile and compressive axial force application

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2014-01-01

    1.1 Included in this practice are methods covering the determination of the amount of bending that occurs during the application of tensile and compressive forces to notched and unnotched test specimens in the elastic range and to plastic strains less than 0.002. These methods are particularly applicable to the force application rates normally used for tension testing, creep testing, and uniaxial fatigue testing.

  19. Plastic deformation and failure mechanisms in nano-scale notched metallic glass specimens under tensile loading

    Science.gov (United States)

    Dutta, Tanmay; Chauniyal, Ashish; Singh, I.; Narasimhan, R.; Thamburaja, P.; Ramamurty, U.

    2018-02-01

    In this work, numerical simulations using molecular dynamics and non-local plasticity based finite element analysis are carried out on tensile loading of nano-scale double edge notched metallic glass specimens. The effect of acuteness of notches as well as the metallic glass chemical composition or internal material length scale on the plastic deformation response of the specimens are studied. Both MD and FE simulations, in spite of the fundamental differences in their nature, indicate near-identical deformation features. Results show two distinct transitions in the notch tip deformation behavior as the acuity is increased, first from single shear band dominant plastic flow localization to ligament necking, and then to double shear banding in notches that are very sharp. Specimens with moderately blunt notches and composition showing wider shear bands or higher material length scale characterizing the interaction stress associated with flow defects display profuse plastic deformation and failure by ligament necking. These results are rationalized from the role of the interaction stress and development of the notch root plastic zones.

  20. Proton irradiation effects on tensile and bend-fatigue properties of welded F82H specimens

    Energy Technology Data Exchange (ETDEWEB)

    Saito, S., E-mail: saito.shigeru@jaea.go.j [JAEA Tokai, J-PARC Center, 2-4 Shirakata-shirane, Tokai-mura, Naka-gun, Ibaraki-ken 319-1195 (Japan); Kikuchi, K.; Hamaguchi, D. [JAEA Tokai, J-PARC Center, 2-4 Shirakata-shirane, Tokai-mura, Naka-gun, Ibaraki-ken 319-1195 (Japan); Usami, K.; Ishikawa, A.; Nishino, Y.; Endo, S. [JAEA Tokai, Department of Hot Laboratories, Tokai-mura, Ibaraki-ken 319-1195 (Japan); Kawai, M. [KEK, Tsukuba-shi, Ibaraki-ken 305-0801 (Japan); Dai, Y. [PSI, Spallation Source Division, 5232 Villigen PSI (Switzerland)

    2010-03-15

    In several institutes, research and development for an accelerator-driven transmutation system (ADS) have been progressed. Ferritic/martensitic (FM) steels are the candidate materials for the beam window of ADS. To evaluate of the mechanical properties of the irradiated materials, the post irradiation examination (PIE) work of the SINQ (Swiss spallation neutron source) target irradiation program (STIP) specimens was carried out at JAEA. In present study, the results of PIE on FM steel F82H and its welded joint have been reported. The present irradiation conditions of the specimens were as follows: proton energy was 580 MeV. Irradiation temperatures were ranged from 130 to 380 deg. C, and displacement damage level was ranged from 5.7 to 11.8 dpa. The results of tensile tests performed at 22 deg. C indicated that the irradiation hardening occurred with increasing the displacement damage up to 10.1 dpa at 320 deg. C irradiation. At higher dose (11.8 dpa) and higher temperature (380 deg. C), irradiation hardening was observed, but degradation of ductility was relaxed in F82H welded joint. In present study, all specimens kept its ductility after irradiation and fractured in ductile manner. The results on bend-fatigue tests showed that the fatigue life (N{sub f}) of F82H base metal irradiated up to 6.3 dpa was almost the same with that of unirradiated specimens. The N{sub f} of the specimens irradiated up to 9.1 dpa was smaller than that of unirradiated specimens. Though the number of specimen was limited, the N{sub f} of F82H EB (15 mm) and EB (3.3 mm) welded joints seemed to increase after irradiation and the fracture surfaces of the specimens showed transgranular morphology. While F82H TIG welded specimens were not fractured by 10{sup 7} cycles.

  1. Status of automated tensile machine

    International Nuclear Information System (INIS)

    Satou, M.; Hamilton, M.L.; Sato, S.; Kohyama, A.

    1992-01-01

    The objective of this work is to develop the Monbusho Automated Tensile machine (MATRON) and install and operate it at the Pacific Northwest Laboratory (PNL). The machine is designed to provide rapid, automated testing of irradiated miniature tensile specimen in a vacuum at elevated temperatures. The MATRON was successfully developed and shipped to PNL for installation in a hot facility. The original installation plan was modified to simplify the current and subsequent installations, and the installation was completed. Detailed procedures governing the operation of the system were written. Testing on irradiated miniature tensile specimen should begin in the near future

  2. Effect of a shear modified Gurson model on damage development in a FSW tensile specimen

    DEFF Research Database (Denmark)

    Nielsen, Kim Lau; Tvergaard, Viggo

    2009-01-01

    For a friction stir welded aluminum plate the resistance to ductile failure is studied by analyzing tensile test specimens cut out across the weldline. As the stress triaxiality is rather low in these tests, the Gurson material model is not expected to give a very accurate description of the void......, such that the damage parameter does not really represent the void volume fraction. Various amounts of the additional damage evolution are compared with predictions of the original Gurson model. The analyses are carried out for different yield stress profiles transverse to the weld and for different specimen widths....... It is found that the modification does provide additional damage development in the friction stir weld, which may help to fit experimental data. But the suggested modification depends strongly on the overall stress state, and may have a too strong effect in some cases where the stress triaxiality is rather...

  3. Radial head button holing: a cause of irreducible anterior radial head dislocation

    Energy Technology Data Exchange (ETDEWEB)

    Shin, Su-Mi; Chai, Jee Won; You, Ja Yeon; Park, Jina [Seoul National University Seoul Metropolitan Government Boramae Medical Center, Department of Radiology, Seoul (Korea, Republic of); Bae, Kee Jeong [Seoul National University Seoul Metropolitan Government Boramae Medical Center, Department of Orthopedic Surgery, Seoul (Korea, Republic of)

    2016-10-15

    ''Buttonholing'' of the radial head through the anterior joint capsule is a known cause of irreducible anterior radial head dislocation associated with Monteggia injuries in pediatric patients. To the best of our knowledge, no report has described an injury consisting of buttonholing of the radial head through the annular ligament and a simultaneous radial head fracture in an adolescent. In the present case, the radiographic findings were a radial head fracture with anterior dislocation and lack of the anterior fat pad sign. Magnetic resonance imaging (MRI) clearly demonstrated anterior dislocation of the fractured radial head through the torn annular ligament. The anterior joint capsule and proximal portion of the annular ligament were interposed between the radial head and capitellum, preventing closed reduction of the radial head. Familiarity with this condition and imaging findings will aid clinicians to make a proper diagnosis and fast decision to perform an open reduction. (orig.)

  4. Modified Nance palatal button

    Directory of Open Access Journals (Sweden)

    Nitin Arora

    2015-01-01

    Full Text Available This paper describes modified Nance palatal button by which problems encountered in the palatal region around the acrylic button during space closure and molar distalization can be minimized.

  5. Energetic optimization of a piezo-based touch-operated button for man–machine interfaces

    International Nuclear Information System (INIS)

    Sun, Hao; De Vries, Theo J A; De Vries, Rene; Van Dalen, Harry

    2012-01-01

    This paper discusses the optimization of a touch-operated button for man–machine interfaces based on piezoelectric energy harvesting techniques. In the mechanical button, a common piezoelectric diaphragm, is assembled to harvest the ambient energy from the source, i.e. the operator’s touch. Under touch force load, the integrated diaphragm will have a bending deformation. Then, its mechanical strain is converted into the required electrical energy by means of the piezoelectric effect presented to the diaphragm. Structural design (i) makes the piezoceramic work under static compressive stress instead of static or dynamic tensile stress, (ii) achieves a satisfactory stress level and (iii) provides the diaphragm and the button with a fatigue lifetime in excess of millions of touch operations. To improve the button’s function, the effect of some key properties consisting of dimension, boundary condition and load condition on electrical behavior of the piezoelectric diaphragm are evaluated by electromechanical coupling analysis in ANSYS. The finite element analysis (FEA) results indicate that the modification of these properties could enhance the diaphragm significantly. Based on the key properties’ different contributions to the improvement of the diaphragm’s electrical energy output, they are incorporated into the piezoelectric diaphragm’s redesign or the structural design of the piezo-based button. The comparison of the original structure and the optimal result shows that electrical energy stored in the diaphragm and the voltage output are increased by 1576% and 120%, respectively, and the volume of the piezoceramic is reduced to 33.6%. These results will be adopted to update the design of the self-powered button, thus enabling a large decrease of energy consumption and lifetime cost of the MMI. (paper)

  6. Biomechanics of the Proximal Radius Following Drilling of the Bicipital Tuberosity to Mimic Cortical Button Distal Biceps Repair Technique.

    Science.gov (United States)

    Oak, Nikhil R; Lien, John R; Brunfeldt, Alexander; Lawton, Jeffrey N

    2018-05-01

    A fracture through the proximal radius is a theoretical concern after cortical button distal biceps fixation in an active patient. The permanent, nonossified cortical defect and medullary tunnel is at risk during a fall eliciting rotational and compressive forces. We hypothesized that during simulated torsion and compression, in comparison with unaltered specimens, the cortical button distal biceps repair model would have decreased torsional and compressive strength and would fracture in the vicinity of the bicipital tuberosity bone tunnel. Sixteen fourth-generation composite radius Sawbones models were used in this controlled laboratory study. A bone tunnel was created through the bicipital tuberosity to mimic the exact bone tunnel, 8 mm near cortex and 3.2 mm far cortex, made for the BicepsButton distal biceps tendon repair. The radius was then prepared and mounted on either a torsional or compression testing device and compared with undrilled control specimens. Compression tests resulted in average failure loads of 9015.2 N in controls versus 8253.25 N in drilled specimens ( P = .074). Torsional testing resulted in an average failure torque of 27.3 Nm in controls and 19.3 Nm in drilled specimens ( P = .024). Average fracture angle was 35.1° in controls versus 21.1° in drilled. Gross fracture patterns were similar in compression testing; however, in torsional testing all fractures occurred through the bone tunnel in the drilled group. There are weaknesses in the vicinity of the bone tunnel in the proximal radius during biomechanical stress testing which may not be clinically relevant in nature. In cortical button fixation, distal biceps repairs creates a permanent, nonossified cortical defect with tendon interposed in the bone tunnel, which can alter the biomechanical properties of the proximal radius during compressive and torsional loading.

  7. Size effect studies on notched tensile specimens at room temperature and 400 {sup o}C

    Energy Technology Data Exchange (ETDEWEB)

    Krompholz, K.; Kamber, J.; Groth, E.; Kalkhof, D

    2000-07-01

    One of the objectives of the REVISA project (REactor Vessel Integrity in Severe Accidents) is to assess the size effect related to deformation and failure models as well as material data under quasistatic and dynamic conditions in homogeneous and non-homogeneous states of strain. For these investigations the reactor pressure vessel material 20 MnMoNi 55 was selected. It was subjected to a size effect study on notched scaled tensile specimens of three sizes. Two strain rates (2*10{sup -5}/s and 10{sup -3}/s) and two temperatures (room temperature and 400 {sup o}C) were selected. The investigations are aimed at a support for a gradient plasticity approach to size effects. Test on the small specimens (diameters 2.4 and 7.2 mm) were performed at an electromechanical test machine, while the large specimens (diameter 24 mm) had to be tested at a servohydraulical closed loop test machine with a force capacity of 1000 kN. All characteristic values were found to be size dependent. A selected semicircular notch retains its shape. The notch opening becomes a chord of a segment of a circle, the notch shape at fracture is a segment of a circle. (author)

  8. Tensile strength of Zr-2.5 Nb pressure tubes: A statistical study

    Energy Technology Data Exchange (ETDEWEB)

    Shah, Priti Kotak, E-mail: pritik@barc.gov.in [Senior Scientist, Bhabha Atomic Research Centre, Mumbai, 400 085 (India); Dubey, J.S.; Datta, D.; Shriwastaw, R.S.; Rath, B.N.; Singh, R.N. [Senior Scientist, Bhabha Atomic Research Centre, Mumbai, 400 085 (India); Anantharaman, S. [Head, Post Irradiation Examination Division, Bhabha Atomic Research Centre, Mumbai (India); Chakravartty, J.K. [Director, Materials Group, Bhabha Atomic Research Centre, Mumbai (India)

    2015-12-15

    Highlights: • Tensile properties in axial and transverse direction for a number of Indian Zr-2.5 Nb PHWR pressure tubes. • Distribution of tensile properties of double-melted and quadruple-melted pressure tubes. • Tensile properties at front-end and back-end of the quadruple melted pressure tubes at room temperature and at 300 °C. - Abstract: In order to get an idea of the statistical variation in the tensile properties of the double-melted as well as quadruple melted Zr-2.5 Nb pressure tubes (PTs) and also the variation in tensile properties between the two ends of the pressure tubes, tension tests were carried out on around 50 pressure tube off-cuts. Longitudinal and transverse tensile specimens were prepared from these off-cuts of pressure tubes of double-melted and quadruple melted types. For quadruple melted pressure tubes the specimens were tested from both front-end and back-end off-cuts. Miniature flat tensile specimens having 1.8 mm width and 1.5 mm thickness and 7.6 mm gauge length were prepared from the pressure tube off-cuts without any flattening treatment. Tension tests were carried out in a screw-driven machine at room temperature and 300 °C for both front-end and back-end off-cuts of each of 16 pressure tubes. In general the transverse specimens showed higher yield strength (YS) and ultimate tensile strength (UTS) compared to the longitudinal specimens. Transverse specimens showed less strain hardening compared to the longitudinal specimens. The axial specimens showed higher uniform (UE) and total elongation (TE) compared to the transverse specimens. Double-melted pressure tubes showed relatively higher strength and lower elongation and larger standard deviation compared to the quadruple melted pressure tubes. Mean values of tensile properties showed that back-end off-cuts were relatively stronger and less ductile compared to the front-end off-cuts.

  9. Fabrication of universal esthetic lingual button

    Directory of Open Access Journals (Sweden)

    Ramkishore Ratre

    2015-01-01

    Full Text Available Lingual buttons are used in many instances for labial, as well as lingual orthodontics. A simple method is demonstrated to fabricate the lingual buttons chair side. The buttons made are aesthetic as they are made from composite resin and can be successfully bonded anywhere on all tooth surfaces.

  10. Tensile Split Hopkinson Bar Technique: Numerical Analysis of the Problem of Wave Disturbance and Specimen Geometry Selection

    Directory of Open Access Journals (Sweden)

    Panowicz Robert

    2016-09-01

    Full Text Available A method of tensile testing of materials in dynamic conditions based on a slightly modified compressive split Hopkinson bar system using a shoulder is described in this paper. The main goal was to solve, with the use of numerical modelling, the problem of wave disturbance resulting from application of a shoulder, as well as the problem of selecting a specimen geometry that enables to study the phenomenon of high strain-rate failure in tension. It is shown that, in order to prevent any interference of disturbance with the required strain signals at a given recording moment, the positions of the strain gages on the bars have to be correctly chosen for a given experimental setup. Besides, it is demonstrated that - on the basis of simplified numerical analysis - an appropriate gage length and diameter of a material specimen for failure testing in tension can be estimated.

  11. Heads Up: Concussion in Youth Sports

    Medline Plus

    Full Text Available ... Submit Button Connect with HEADS UP & CDC's Injury Center HEADS UP Resources File Formats Help: How do ... Page last updated: April 24, 2017 Content source: Centers for Disease Control and Prevention , National Center for ...

  12. Comparison of polymer-based temporary crown and fixed partial denture materials by diametral tensile strength.

    Science.gov (United States)

    Ha, Seung-Ryong; Yang, Jae-Ho; Lee, Jai-Bong; Han, Jung-Suk; Kim, Sung-Hun

    2010-03-01

    The purpose of this study was to investigate the diametral tensile strength of polymer-based temporary crown and fixed partial denture (FPD) materials, and the change of the diametral tensile strength with time. One monomethacrylate-based temporary crown and FPD material (Trim) and three dimethacrylate-based ones (Protemp 3 Garant, Temphase, Luxtemp) were investigated. 20 specimens (ø 4 mm × 6 mm) were fabricated and randomly divided into two groups (Group I: Immediately, Group II: 1 hour) according to the measurement time after completion of mixing. Universal Testing Machine was used to load the specimens at a cross-head speed of 0.5 mm/min. The data were analyzed using one-way ANOVA, the multiple comparison Scheffe test and independent sample t test (α = 0.05). Trim showed severe permanent deformation without an obvious fracture during loading at both times. There were statistically significant differences among the dimethacrylate-based materials. The dimethacrylate-based materials presented an increase in strength from 5 minutes to 1 hour and were as follows: Protemp 3 Garant (23.16 - 37.6 MPa), Temphase (22.27 - 28.08 MPa), Luxatemp (14.46 - 20.59 MPa). Protemp 3 Garant showed the highest value. The dimethacrylate-based temporary materials tested were stronger in diametral tensile strength than the monomethacrylate-based one. The diametral tensile strength of the materials investigated increased with time.

  13. Analysis of surface roughening behavior of 6063 aluminum alloy by tensile testing of a trapezoidal uniaxial specimen

    Energy Technology Data Exchange (ETDEWEB)

    Cai, Yang [School of Materials Science and Engineering, Harbin Institute of Technology, Harbin 150090 (China); Wang, Xiaosong, E-mail: hitxswang@hit.edu.cn [School of Materials Science and Engineering, Harbin Institute of Technology, Harbin 150090 (China); National Key Laboratory of Precision Hot Processing of Metals, Harbin Institute of Technology, Harbin 150001 (China); Yuan, Shijian [School of Materials Science and Engineering, Harbin Institute of Technology, Harbin 150090 (China); National Key Laboratory of Precision Hot Processing of Metals, Harbin Institute of Technology, Harbin 150001 (China)

    2016-08-30

    To determine the quantitative relationship between surface roughness and strain, the surface roughening behavior of a 6063 aluminum alloy tube was examined by tensile testing of a trapezoidal uniaxial specimen, that can provide a continuous strain distribution after tensile deformation. The surface roughness was measured using a laser scanning confocal microscope to reflect the degree of roughening. The microstructure and surface morphology were examined using electron back-scattered diffraction and in-situ scanning electron microscopy to determine the grain orientation and surface topography evolution. The surface roughness increased with strain when the strain was less than 0.067 and then decreased slightly, with a maximum surface roughness of 23.73 µm. Inhomogeneous deformation at the grain boundaries and inside the grains was enhanced with increasing strain, resulting in an increase of surface roughness when the strain was below a critical value. As the strain increased, a greater number of slip systems contributed to the further deformation. Thus, the strain became more homogeneous, and accordingly, the surface roughness slightly decreased.

  14. Button batteries

    Science.gov (United States)

    Swallowing batteries ... These devices use button batteries: Calculators Cameras Hearing aids Penlights Watches ... If a person puts the battery up their nose and breathes it further in, ... problems Cough Pneumonia (if the battery goes unnoticed) ...

  15. A combined experimental and FE analysis procedure to evaluate tensile behavior of zircaloy pressure tubes

    International Nuclear Information System (INIS)

    Samal, M.K.; Vaze, K.K.; Balakrishnan, K.S.; Anantharaman, S.

    2012-01-01

    Determination of transverse mechanical properties from the ring type of specimens directly machined from the nuclear reactor pressure tubes is not straightforward because of the presence of combined membrane as well as bending stresses arising in the loaded condition. In this work, we have performed ring-tensile tests on the un-irradiated ring tensile specimen using two split semi-cylindrical mandrels as the loading device. A 3-D finite element (FE) analysis was performed in order to determine the material true stress-strain curve by comparing experimental load-displacement data with those predicted by FE analysis. In order to validate the methodology, miniaturized tensile specimens were machined from these tubes and tested. It was observed that the stress-strain data as obtained from ring tensile specimen could describe the load displacement curve of the miniaturized flat tensile specimen very well. (author)

  16. Notch Effect on Tensile Deformation Behavior of 304L and 316L Steels in Liquid Helium and Hydrogen

    International Nuclear Information System (INIS)

    Shibata, K.; Fujii, H.

    2004-01-01

    Tensile tests of type 304L and 316L steels were carried out using round bar specimens with a notch in liquid helium, hydrogen, liquid nitrogen and at ambient temperature. The obtained tensile strengths were compared with the tensile strengths of smooth specimens. For smooth specimens, tensile strength increased with a decrease in temperature and the strengths in liquid helium and hydrogen show similar values in both steels. For notched specimen of 304L steel, tensile strength (including fracture strength) increased noticeably from ambient to liquid nitrogen temperature but showed a large decrease in liquid helium and hydrogen. In liquid hydrogen and helium, the tensile strength is a little lower in liquid hydrogen than in liquid helium and both strengths are lower than tensile strengths of smooth specimens. For notched specimen of 316L steel, an increase in tensile strength from ambient to liquid nitrogen temperature was not so large and a decrease from liquid nitrogen to liquid hydrogen was small. The tensile strengths in liquid helium and hydrogen were nearly same and higher than those of smooth specimens. Different behavior of serration was observed between liquid helium and hydrogen, and between 304L and 316L steels. The reasons for these differences were discussed using computer simulation

  17. Button battery ingestion in children: An emerging hazard

    Directory of Open Access Journals (Sweden)

    Mayank Jain

    2013-01-01

    Full Text Available Button battery ingestion is an emerging hazard. In this retrospective study, we report six cases of lithium button battery ingestion in pediatric age group (mean age 2.8 years. Three button batteries were removed from stomach and three from esophagus. Esophageal site was associated with significant local injury, and one button battery was impacted in the esophagus, requiring rigid esophagoscopy for removal. Small battery size, used batteries, and early removal (<12 h after ingestion were associated with lesser mucosal injury. No long-term complications were noted. Our study emphasizes that early diagnosis and urgent removal of ingested button battery are the only measures which prevent complications.

  18. Manufacturing and properties of closure head forging integrated with flange for PWR reactor pressure vessel

    International Nuclear Information System (INIS)

    Tomoharu Sasaki; Iku Kurihara; Etsuo Murai; Yasuhiko Tanaka; Koumei Suzuki

    2003-01-01

    Closure head forging (SA508, Gr.3 Cl.1) integrated with flange for PWR reactor pressure vessel has been developed. This is intended to enhance structural integrity of closure head resulted in elimination of ISI, by eliminating weld joint between closure head and flange in the conventional design. Manufacturing procedures have been established so that homogeneity and isotropy of the material properties can be assured in the closure head forging integrated with flange. Acceptance tensile and impact test specimens are taken and tested regarding the closure head forging integrated with flange as very thick and complex forgings. This paper describes the manufacturing technologies and material properties of the closure head forging integrated with flange. (orig.)

  19. Development of the transverse tensile and fracture toughness test techniques for spent fuel cladding

    Energy Technology Data Exchange (ETDEWEB)

    Ahn, S. B.; Hong, K. P.; Jung, Y. H.; Seo, H. S.; Oh, W. H.; Yoo, B. O.; Kim, D. S.; Seo, K. S

    2001-12-01

    To define the cause of cladding damage which can take place during the operation of nuclear power plant and the storage through the degradation aspect of mechanical characteristics, the transverse tensile an fracture toughness test were developed in hot cell at IMEF(Irradiated Material Experiment Facility). The following hot cell techniques were developed. 1. The development of a jig and a specimen for transverse tensile test 2. The acquisition of a manufacturing technique for the transverse tensile specimen at hot cell 3. The acquisition of testing procedures and an analysis technque for the transverse tensile 4. The dimensional determination of an optimized fracture toughness specimen 5. The acquisition of manufacturing technique for the fracture toughness test specimen at the hot cell 6. The acquisition of testing procedures and analysis technique for the fracture toughness test (Multiple specimen method, DCPD method, Load ratio method)

  20. Tensile testing and damage analysis of woven glass-cloth/epoxy laminates at low temperature

    International Nuclear Information System (INIS)

    Kumagai, S.; Shindo, Y.; Horiguchi, K.

    2002-01-01

    In order to evaluate the tensile properties of SL-ES30 glass-cloth/epoxy laminates for superconducting magnets in fusion energy systems, tensile tests were examined both experimentally and analytically. The tensile tests were conducted in accordance with JIS K 7054 at room temperature and liquid nitrogen temperature (77 K). The general specimen geometry was a rectangular dog-bone shape with constant gage length, but with each specimen size having a different specimen width. The experimental finding provides the data for analytical modeling. The model utilizes two damage variables which are determined from experimental data. A finite element method coupled with damage was adopted for the extensional analysis. The effects of temperature, specimen geometry and gripping method on the tensile properties are examined

  1. Insertion of Balloon Retained Gastrostomy Buttons: A 5-Year Retrospective Review of 260 Patients

    International Nuclear Information System (INIS)

    Power, Sarah; Kavanagh, Liam N.; Shields, Mary C.; Given, Mark F.; Keeling, Aoife N.; McGrath, Frank P.; Lee, Michael J.

    2013-01-01

    Radiologically inserted gastrostomy (RIG) is an established way of maintaining enteral nutrition in patients who cannot maintain nutrition orally. The purpose of this study was to evaluate the safety and efficacy of primary placement of a wide bore button gastrostomy in a large, varied patient population through retrospective review. All patients who underwent gastrostomy placement from January 1, 2004 to January 1, 2009 were identified. 18-Fr gastrostomy buttons (MIC-Key G) were inserted in the majority. Follow-up ranged from 6 months to 4.5 years. A total of 260 patients (M:F 140:120, average age 59.2 years) underwent gastrostomy during the study period. Overall success rate for RIG placement was 99.6 %, with success rate of 95.3 % for primary button insertion. Indications included neurological disorders (70 %), esophageal/head and neck malignancy (21 %), and other indications (9 %). Major and minor complication rates were 1.2 and 12.8 %, respectively. Thirty-day mortality rate was 6.8 %. One third of patients underwent gastrostomy reinsertion during the study period, the main indication for which was inadvertent catheter removal. Patency rate was high at 99.5 %. The maximum number of procedures in any patient was 8 (n = 2), and the average tube dwell time was 125 days. Primary radiological insertion of a wide bore button gastrostomy is a safe technique, with high success rate, high patency rate, and low major complication rate. We believe that it is feasible to attempt button gastrostomy placement in all patients, once tract length is within limits of tube length. If difficulty is encountered, then a standard tube may simply be placed instead.

  2. Insertion of Balloon Retained Gastrostomy Buttons: A 5-Year Retrospective Review of 260 Patients

    Energy Technology Data Exchange (ETDEWEB)

    Power, Sarah, E-mail: sarahpower28@yahoo.co.uk; Kavanagh, Liam N.; Shields, Mary C.; Given, Mark F.; Keeling, Aoife N.; McGrath, Frank P.; Lee, Michael J., E-mail: mlee@rcsi.ie [Beaumont Hospital, Department of Radiology (Ireland)

    2013-04-15

    Radiologically inserted gastrostomy (RIG) is an established way of maintaining enteral nutrition in patients who cannot maintain nutrition orally. The purpose of this study was to evaluate the safety and efficacy of primary placement of a wide bore button gastrostomy in a large, varied patient population through retrospective review. All patients who underwent gastrostomy placement from January 1, 2004 to January 1, 2009 were identified. 18-Fr gastrostomy buttons (MIC-Key G) were inserted in the majority. Follow-up ranged from 6 months to 4.5 years. A total of 260 patients (M:F 140:120, average age 59.2 years) underwent gastrostomy during the study period. Overall success rate for RIG placement was 99.6 %, with success rate of 95.3 % for primary button insertion. Indications included neurological disorders (70 %), esophageal/head and neck malignancy (21 %), and other indications (9 %). Major and minor complication rates were 1.2 and 12.8 %, respectively. Thirty-day mortality rate was 6.8 %. One third of patients underwent gastrostomy reinsertion during the study period, the main indication for which was inadvertent catheter removal. Patency rate was high at 99.5 %. The maximum number of procedures in any patient was 8 (n = 2), and the average tube dwell time was 125 days. Primary radiological insertion of a wide bore button gastrostomy is a safe technique, with high success rate, high patency rate, and low major complication rate. We believe that it is feasible to attempt button gastrostomy placement in all patients, once tract length is within limits of tube length. If difficulty is encountered, then a standard tube may simply be placed instead.

  3. Esophageal button battery ingestion in children.

    Science.gov (United States)

    Şencan, Arzu; Genişol, İncinur; Hoşgör, Münevver

    2017-07-01

    Button battery lodged in the esophagus carries a high risk of morbidity and mortality. The purpose of this study was to present cases of patients with esophageal button battery ingestion treated at our clinic and to emphasize the importance of early diagnosis and treatment. Records of patients admitted to our hospital for foreign body ingestion between January 2010 and May 2015 were retrospectively reviewed. Cases with button battery lodged in the esophagus were included in the study. Patient data regarding age, sex, length of time after ingestion until admission, presenting clinical symptoms, type and localization of the battery, management, and prognosis were analyzed. Among 1891 foreign body ingestions, 71 were localized in the esophagus, and 8 of those (11.2%) were cases of button battery ingestion. Mean age was 1.7 years. Admission was within 6 hours of ingestion in 5 cases, after 24 hours had elapsed in 2, and 1 month after ingestion in 1 case. All patients but 1 knew the history of ingestion. Prompt endoscopic removal was performed for all patients. Three patients developed esophageal stricture, which responded to dilatation. Early recognition and timely endoscopic removal is mandatory in esophageal button battery ingestion. It should be suspected in the differential diagnosis of patients with persistent respiratory and gastrointestinal symptoms.

  4. Preliminary study on tensile properties and fractography of the recycled aluminum cast product

    International Nuclear Information System (INIS)

    Hishamuddin Hussain; Mohd Harun; Hafizal Yazid; Shaiful Rizam Shamsudin; Zaiton Selamat; Mohd Shariff Sattar

    2004-01-01

    Among many mechanical properties of materials, tensile properties are probably the most frequently considered, evaluated, and referred by the industry. This paper presents the result of preliminary study regarding the tensile properties and fractography of the recycled aluminum cast product. For this purpose, three sets of specimen were prepared for tensile testing by using permanent mold casting technique. The cast products are in durable shaped tensile specimens with the gauge length of 50mm. The tensile testing was conducted in accordance with BS EN 10002-1 and ISO 6892 standards. Fracture surface analysis was also conducted to understand materials behaviour. (Author)

  5. Drying time of tray adhesive for adequate tensile bond strength between polyvinylsiloxane impression and tray resin material.

    Science.gov (United States)

    Yi, Myong-Hee; Shim, Joon-Sung; Lee, Keun-Woo; Chung, Moon-Kyu

    2009-07-01

    Use of custom tray and tray adhesive is clinically recommended for elastomeric impression material. However there is not clear mention of drying time of tray adhesive in achieving appropriate bonding strength of tray material and impression material. This study is to investigate an appropriate drying time of tray adhesives by evaluating tensile bonding strength between two types of polyvinylsiloxane impression materials and resin tray, according to various drying time intervals of tray adhesives, and with different manufacturing company combination of impression material and tray adhesive. Adhesives used in this study were Silfix (Dentsply Caulk, Milford, Del, USA) and VPS Tray Adhesive (3M ESPE, Seefeld, Germany) and impression materials were Aquasil Ultra (monophase regular set, Dentsply Caulk, Milford, Del, USA) and Imprint II Garant (regular body, 3M ESPE, Seefeld, Germany). They were used combinations from the same manufacture and exchanged combinations of the two. The drying time was designed to air dry, 5 minutes, 10 minutes, 15 minutes, 20 minutes, and 25 minutes. Total 240 of test specimens were prepared by auto-polymerizing tray material (Instant Tray Mix, Lang, Wheeling, Il, USA) with 10 specimens in each group. The specimens were placed in the Universal Testing machine (Instron, model 3366, Instron Corp, University avenue, Nowood, MA, USA) to perform the tensile test (cross head speed 5 mm/min). The statistically efficient drying time was evaluated through ANOVA and Scheffe test. All the tests were performed at 95% confidence level. The results revealed that at least 10 minutes is needed for Silfix-Aquasil, and 15 minutes for VPS Tray Adhesive-Imprint II, to attain an appropriate tensile bonding strength. VPS Tray Adhesive-Imprint II had a superior tensile bonding strength when compared to Silfix-Aquasil over 15 minutes. Silfix-Aquasil had a superior bonding strength to VPS Tray Adhesive-Aquasil, and VPS Tray Adhesive-Imprint II had a superior tensile

  6. Evolution of cleared channels in neutron-irradiated pure copper as a function of tensile strain

    DEFF Research Database (Denmark)

    Edwards, D.J.; Singh, B.N.

    2004-01-01

    Tensile specimens of pure copper were neutron irradiated at similar to323 K to a displacement dose of 0.3 dpa (displacement per atom). Five irradiated specimens were tensile tested at 300 K, but four of the specimens were stopped at specific strains -just before the yield point at similar to90......% of the macroscopic yield, at 1.5% and 5% elongation, and near the ultimate tensile strength at 14.5% elongation, with the 5th specimen tested to failure (e(T) = 22%). SEM and TEM characterization of the deformed specimens revealed that the plastic strain was confined primarily to the 'cleared' channels only...

  7. The Button Sew Machine. Module 12.

    Science.gov (United States)

    South Carolina State Dept. of Education, Columbia. Office of Vocational Education.

    This module on the button sew machine, one in a series dealing with industrial sewing machines, their attachments, and operation, covers one topic: performing special operations on the button sew machine. These components are provided: an introduction, direction, an objective, learning activities, student information, a student self-check, and a…

  8. Neutron diffraction measurements for the determination of residual stresses in MMC tensile and fatigue specimens

    DEFF Research Database (Denmark)

    Fiori, F.; Girardin, E.; Giuliani, A.

    2000-01-01

    have been performed at RISO (Roskilde, DK) and HMI-BENSC (Berlin, D), for the determination of residual stress in AA2124 + 17% SiCp and AA359 + 20% SiCp specimens, submitted to tensile and fatigue tests. For each of the investigated samples, the macrostress has been separated from the elastic......, residual stresses are present in both the matrix and the particles microstructure, prior to any macroscopic loading. They vary with the temperature and with the type and level of loading imposed to the material, having a strong influence on the mechanical behaviour of MMCs. Neutron diffraction measurements...... and thermal mismatch microstresses. The results show that, in general, the main contribution to the stress state of both matrix and reinforcement is given by the thermal microstresses, already existing due to heat treatment prior to mechanical tests. (C) 2000 Elsevier Science B.V. All rights reserved....

  9. Evaluation of ring tensile test results

    International Nuclear Information System (INIS)

    Chatterjee, S.; Anantharaman, S.; Balakrishnan, K.S.; Sivaramakrish, K.S.

    1990-01-01

    Ring specimens of 5-mm width cut from Zircaloy-2 cladding of reactor operated fuel elements that had experienced 5000 to 15,000 MWD/T of fuel burnup were subjected to ring tensile testing. The true stress-true strain data points up to the onset of necking from the individual load-elongation curves of these specimens were used as input data in Voce's equation. The results reveal that the uniform elongation (UE) values generated using Voce's equation were within (UE-2)% of the experimental percent uniform elongation (UE%). The corresponding ultimate tensile strength values were within ±1%. The uncertainty inherently associated in the determination of gauge length introduces extraneous deformation in the rings tested. Previous results had shown that a 14% increase in cladding diameter caused the gauge length to increase by 40%. To simulate the contribution of extraneous deformation due to an increase in cladding diameter, an analysis of the variation of the tensile parameters (uniform elongation and ultimate tensile strength) due to increase in the gauge length in the range of 10 to 40% was carried out. The results are discussed

  10. Elevator buttons as unrecognized sources of bacterial colonization in hospitals.

    Science.gov (United States)

    Kandel, Christopher E; Simor, Andrew E; Redelmeier, Donald A

    2014-01-01

    Elevators are ubiquitous and active inside hospitals, potentially facilitating bacterial transmission. The objective of this study was to estimate the prevalence of bacterial colonization on elevator buttons in large urban teaching hospitals. A total of 120 elevator buttons and 96 toilet surfaces were swabbed over separate intervals at 3 tertiary care hospitals on weekdays and weekends in Toronto, Ontario. For the elevators, swabs were taken from 2 interior buttons (buttons for the ground floor and one randomly selected upper-level floor) and 2 exterior buttons (the "up" button from the ground floor and the "down" button from the upper-level floor). For the toilet surfaces, swabs were taken from the exterior and interior handles of the entry door, the privacy latch, and the toilet flusher. Samples were obtained using standard bacterial collection techniques, followed by plating, culture, and species identification by a technician blind to sample source. The prevalence of colonization of elevator buttons was 61% (95% confidence interval 52%-70%). No significant differences in colonization prevalence were apparent in relation to location of the buttons, day of the week, or panel position within the elevator. Coagulase-negative staphylococci were the most common organisms cultured, whereas Enterococcus and Pseudomonas species were infrequent. Elevator buttons had a higher prevalence of colonization than toilet surfaces (61% v. 43%, p = 0.008). Hospital elevator buttons were commonly colonized by bacteria, although most pathogens were not clinically relevant. The risk of pathogen transmission might be reduced by simple countermeasures.

  11. DYNAMIC TENSILE TESTING WITH A LARGE SCALE 33 MJ ROTATING DISK IMPACT MACHINE

    OpenAIRE

    Kussmaul , K.; Zimmermann , C.; Issler , W.

    1985-01-01

    A recently completed testing machine for dynamic tensile tests is described. The machine consists essentially of a pendulum which holds the specimen and a large steel disk with a double striking nose fixed to its circumference. Disk diameter measures 2000 mm, while its mass is 6400 kg. The specimens to be tested are tensile specimens with a diameter of up to 20 mm and 300 mm length or CT 15 specimens at various temperatures. Loading velocity ranges from 1 to 150 m/s. The process of specimen-n...

  12. Design of a cruciform bend specimen for determination of out-of- plane biaxial tensile stress effects on fracture toughness for shallow cracks

    International Nuclear Information System (INIS)

    Bass, B.R.; Bryson, J.W.; Mcafee, W.J.; Pennell, W.E.; Theiss, T.J.

    1993-01-01

    Pressurized-thermal-shock loading in a reactor pressure vessel produces significant positive out-of-plane stresses along the crack front for both circumferential and axial cracks. Experimental evidence, while very limited, seems to indicate that a reduction in toughness is associated with out-of-plane biaxial loading when compared with toughness values obtained under uniaxial conditions. A testing program is described that seeks to determine the effects of out-of-plane biaxial tensile loading on fracture toughness of RPV steels. A cruciform bend specimen that meets specified criteria for the testing pregam is analyzed using three-dimensional elastic-plastic finite-element techniques. These analysis results provide the basis for proposed test conditions that are judged likely to produce a biaxial loading effect in the cruciform bend specimen

  13. Experimental Investigation of the Effects of Concrete Alkalinity on Tensile Properties of Preheated Structural GFRP Rebar

    Directory of Open Access Journals (Sweden)

    Hwasung Roh

    2017-01-01

    Full Text Available The combined effects of preexposure to high temperature and alkalinity on the tensile performance of structural GFRP reinforcing bars are experimentally investigated. A total of 105 GFRP bar specimens are preexposed to high temperature between 120°C and 200°C and then immersed into pH of 12.6 alkaline solution for 100, 300, and 660 days. From the test results, the elastic modulus obtained at 300 immersion days is almost the same as those of 660 immersion days. For all alkali immersion days considered in the test, the preheated specimens provide slightly lower elastic modulus than the unpreheated specimens, showing only 8% maximum difference. The tensile strength decreases for all testing cases as the increase of the alkaline immersing time, regardless of the prehearing levels. The tensile strength of the preheated specimens is about 90% of the unpreheated specimen for 300 alkali immersion days. However, after 300 alkali immersion days the tensile strengths are almost identical to each other. Such results indicate that the tensile strength and elastic modulus of the structural GFRP reinforcing bars are closely related to alkali immersion days, not much related to the preheating levels. The specimens show a typical tensile failure around the preheated location.

  14. Microstructure, Tensile and Fatigue Properties of Al-5 wt.%Mg Alloy Manufactured by Twin Roll Strip Casting

    Science.gov (United States)

    Heo, Joon-Young; Baek, Min-Seok; Euh, Kwang-Jun; Lee, Kee-Ahn

    2018-04-01

    This study investigated the microstructure, tensile and fatigue properties of Al-5 wt.%Mg alloy manufactured by twin roll strip casting. Strips cast as a fabricated (F) specimen and a specimen heat treated (O) at 400 °C/5 h were produced and compared. In the F specimen, microstructural observation discovered clustered precipitates in the center area, while in the O specimen precipitates were relatively more evenly distributed. Al, Al6(Mn, Fe), Mg2Al3 and Mg2Si phases were observed. However, most of the Mg2Al3 phase in the heat-treated O specimen was dissolved. A room temperature tensile test measured yield strength of 177.7 MPa, ultimate tensile strength of 286.1 MPa and elongation of 11.1% in the F specimen and 167.7 MPa (YS), 301.5 MPa (UTS) and 24.6% (EL) in the O specimen. A high cycle fatigue test measured a fatigue limit of 145 MPa in the F specimen and 165 MPa in the O specimen, and the O specimen achieved greater fatigue properties in all fatigue stress conditions. The tensile and fatigue fracture surfaces of the above-mentioned specimens were observed, and this study attempted to investigate the tensile and fatigue deformation behavior of strip cast Al-5 wt.%Mg based on the findings.

  15. The Effect of Gap Angle on Tensile Strength of Preceramic Base Metal Solder Joints.

    Science.gov (United States)

    Fattahi, Farnaz; Hashemi Ardakani, Zahra; Hashemi Ardakani, Maryam

    2015-12-01

    Soldering is a process commonly used in fabricating dental prosthesis. Since most soldered prosthesis fail at the solder joints; the joint strength is of utmost importance. The purpose of this study was to evaluate the effect of gap angle on the tensile strength of base metal solder joints. A total number of 40 Ni-Cr samples were fabricated according to ADA/ISO 9693 specifications for tensile test. Samples were cut at the midpoint of the bar, and were placed at the considered angles by employing an explicitly designed device. They were divided into 4 groups regarding the gap angle; Group C (control group) with parallel gap on steady distance of 0.2mm, Group 1: 10°, Group 2: 20°, and Group3: 30° gap angles. When soldered, the specimens were all tested for tensile strength using a universal testing machine at a cross-head speed of 0.5 mm/min with a preload of 10N. Kruskal-Wallis H test was used to compare tensile strength among the groups (ptensile strength values obtained from the study groups were respectively 307.84, 391.50, 365.18, and 368.86 MPa. The tensile strength was not statistically different among the four groups in general (p≤ 0.490). Making the gap angular at the solder joints and the subsequent unsteady increase of the gap distance would not change the tensile strength of the joint.

  16. Button self-retaining drainage catheter

    International Nuclear Information System (INIS)

    Caridi, James G.; Hawkins, Irvin F.; Akins, E. William; Young, Ronald S.

    1997-01-01

    To help improve patient acceptance of long-term internal/external catheter access to the biliary tract in those with benign biliary obstruction, a simple design allows the catheter end to remain flush with the skin. It consists of a clothes button affixed to the drainage catheter with a wood screw after the catheter has been cut off at the skin exit. This button/screw device has been used successfully in 22 patients over the last 10 years; catheter exchanges were easily accomplished

  17. New strain measurement method at axial tensile test of thin films through direct imaging

    Energy Technology Data Exchange (ETDEWEB)

    Ha, Jong-Eun [Department of Automotive Engineering, Seoul National Uinversity of Technolgy, 172 Gongneung-2 Dong, Nowon-Gu, Seoul (Korea, Republic of); Park, Jun-Hyub [Department of Mechatronics Engineering, College of Engineering, Tongmyong University, 535, Yongdang-Dong, Nam-Gu, Busan 608-711 (Korea, Republic of); Kang, Dong-Joong [School of Mechanical Eng., Pusan National University, Jangjeon-dong, Geumjeong-gu, Busan 609-735 (Korea, Republic of)], E-mail: jhyubpark@korea.com

    2008-09-07

    This paper proposes a new method for measuring strain during a tensile test of the specimen with micrometre size through direct imaging. A specimen was newly designed for adoption of direct imaging which was the main contribution of the proposed system. The structure of the specimen has eight indicators that make it possible to adopt direct imaging and it is fabricated using the same process of microelectromechanical system (MEMS) devices to guarantee the feasibility of the tensile test. We implemented a system for non-contact in situ measurement of strain with the specimen, the image-based displacement measurement system. Extension of the gauge length in the specimen could be found robustly by computing the positions of the eight rectangular-shape indicators on the image. Also, for an easy setup procedure, the region of interest was found automatically through the analysis of the edge projection profile along the horizontal direction. To gain confidence in the reliability of the system, the tensile test for the Al-3%Ti thin film was performed, which is widely used as a material in MEMS devices. Tensile tests were performed and displacements were measured using the proposed method and also the capacitance type displacement sensor for comparison. It is demonstrated that the new strain measurement system can be effectively used in the tensile test of the specimen at microscale with easy setup and better accuracy.

  18. Mechanical Properties of Commercial Carbon Fibers Using a Single Filament Tensile Test

    International Nuclear Information System (INIS)

    Joh, Han-Ik; Song, Hae Kyung; Ku, Bon-Cheol; Lee, Sungho; Kim, Ki-Young; Kang, Phil-Hyun

    2013-01-01

    In this study, mechanical properties of commercial carbon fibers were evaluated using a single filament tensile test with various fiber gauge lengths. Tensile strength increased significantly with a decreasing length of the test specimens possibly due to small defect sites. The compliance method provided more accurate moduli of the carbon fibers, removing system errors during the single filament tensile test. The Weibull modulus revealed that shorter specimens had an inhomogeneous defect distribution, leading to a higher tensile strength and its standard deviation. X-ray diffractograms of carbon fibers showed a similar crystallinity and orientation in spite of significant differences in the fiber modulus and strength, indicating that crystalline structure of the commercial carbon fibers used in the study was not attributable to the difference in their tensile properties.

  19. Vacuum fused deposition modelling system to improve tensile ...

    African Journals Online (AJOL)

    In the printing process, the interlayer bonding is made too quick thus the layers are not fully fused together causing the reduced tensile strength. This paper presents a possible solution to this problem by incorporating vacuum technology in FDM system to improve tensile strength of 3D printed specimens. In this study, a ...

  20. Location specific in situ TEM straining specimens made using FIB

    International Nuclear Information System (INIS)

    Field, R.D.; Papin, P.A.

    2004-01-01

    A method has been devised and demonstrated for producing in situ straining specimens for the transmission electron microscope (TEM) from specific locations in a sample using a dual-beam focused ion beam (FIB) instrument. The specimen is removed from a polished surface in the FIB using normal methods and then attached to a pre-fabricated substrate in the form of a modified TEM tensile specimen. In this manner, specific features of the microstructure of a polished optical mount can be selected for in situ tensile straining. With the use of electron backscattered diffraction (EBSD), this technique could be extended to select specific orientations of the specimen as well

  1. The anesthetic management of button battery ingestion in children.

    Science.gov (United States)

    Ing, Richard J; Hoagland, Monica; Mayes, Lena; Twite, Mark

    2018-03-01

    Injuries related to button battery ingestion are common in children. This review provides an outline of the epidemiology, pathophysiology, management, and anesthetic implications in children who have ingested a button battery. A literature search was conducted in the United States National Library of Medicine PubMed database using the terms "button battery ingestion" and "children' and "removal" and "surgery" and "anesthesia". Ninety-six articles published in English were found from 1983-2017, and 62 of these articles were incorporated into this review. Additionally, the Internet was searched with the terms "button battery ingestion and children" to identify further entities, organizations, and resources affiliated with button battery ingestion in children. These additional sources were studied and included in this review. Button batteries are ubiquitous in homes and electronic devices. Since 2006, larger-diameter and higher-voltage batteries have become available. These are more likely to become impacted in the esophagus after ingestion and lead to an increase in severe morbidity and mortality due to caustic tissue injury. Children at the highest risk for complications are those under six years of age who have ingested batteries > 20 mm in diameter and sustain prolonged esophageal impaction at the level of the aortic arch with the negative pole oriented anteriorly. Anesthesiologists need to know about the epidemiology, pathophysiology, complications, and anesthetic management of children who have ingested button batteries.

  2. Post-Impact and Open Hole Tensile Of Kenaf Hybrid Composites

    Science.gov (United States)

    Yunus, S.; Salleh, Z.; Masdek, N. R. N. M.; Taib, Y. M.; Azhar, I. I. S.; Hyie, K. M.

    2018-03-01

    Nowadays, kenaf hybrid glass composites has been used for a vast field of study throughout the globe. There are several compositions and orientation of kenaf hybrid glass composites that has been studied. With regards to the study that has been done, this study will be focussing on a 90FG/0/90/90/0/90FG orientation of kenaf hybrid glass composites. Polyester resin is used as a matrix to these hybrid composites. Impacted and open hole specimens were then analyzed through tensile test. All specimens were fabricated by using the cold press hand lay-up technique. The results revealed that the hybrid composites were hardly affected by the impact up to 6J. After 6J the impacted specimens experienced a significant damage for both strength and modulus. The same goes to open hole specimens where the same trend of tensile properties were observed as impacted specimens.

  3. Tensile strength of laser welded cobalt-chromium alloy with and without an argon atmosphere.

    Science.gov (United States)

    Tartari, Anna; Clark, Robert K F; Juszczyk, Andrzej S; Radford, David R

    2010-06-01

    The tensile strength and depth of weld of two cobalt chromium alloys before and after laser welding with and without an argon gas atmosphere were investigated. Using two cobalt chromium alloys, rod shaped specimens (5 cm x 1.5 mm) were cast. Specimens were sand blasted, sectioned and welded with a pulsed Nd: YAG laser welding machine and tested in tension using an Instron universal testing machine. A statistically significant difference in tensile strength was observed between the two alloys. The tensile strength of specimens following laser welding was significantly less than the unwelded controls. Scanning electron microscopy showed that the micro-structure of the cast alloy was altered in the region of the weld. No statistically significant difference was found between specimens welded with or without an argon atmosphere.

  4. Serious complications after button battery ingestion in children.

    Science.gov (United States)

    Krom, Hilde; Visser, Margot; Hulst, Jessie M; Wolters, Victorien M; Van den Neucker, Anita M; de Meij, Tim; van der Doef, Hubert P J; Norbruis, Obbe F; Benninga, Marc A; Smit, Margot J M; Kindermann, Angelika

    2018-05-02

    Serious and fatal complications after button battery ingestion are increasing worldwide. The aim of this study is to describe serious complications after battery ingestion in children in the Netherlands.All pediatric gastroenterologists in the Netherlands performing upper endoscopies were asked to report all serious complications after battery ingestion in children (0-18 years) between 2008 and 2016 retrospectively.Sixteen serious complications were reported: death after massive bleeding through esophageal-aortal fistula (n = 1), esophageal-tracheal fistula (n = 5), stenosis after (suspected) perforation and mediastinitis (n = 5), (suspected) perforation and mediastinitis (n = 3), vocal cord paralysis (n = 1), and required reintubation for dyspnea and stridor (n = 1). The median time interval between ingestion and presentation was 5 (IQR 2-258) h. All children were ≤ 5 (median 1.4; IQR 0.9-2.1) years. Vomiting (31.3%), swallowing/feeding problems (31.3%), and fever (31.3%) were the most common presenting symptoms; however, 18.8% of the patients were asymptomatic (n = 1 missing). All batteries were button batteries (75% ≥ 20 mm; 18.8% batteries were removed by esophagogastroduodenoscopy (50%) and rigid endoscopy (37.5%) or surgically (12.5%). Sixteen serious complications occurred after small and large button batteries ingestion between 2008 and 2016 in both symptomatic and asymptomatic children in the Netherlands. Therefore, immediate intervention after (suspected) button battery ingestion is required. What is Known: • Button battery ingestion may result in serious and fatal complications. • Serious and fatal complications after button battery ingestion are increasing worldwide. What is New: • Sixteen serious complications after button battery ingestion occurred during 2008-2016 in children in the Netherlands. • Serious complications were also caused by small batteries (< 20 mm) in the Netherlands and also occurred

  5. The like economy: social buttons and the data-intensive web

    NARCIS (Netherlands)

    Gerlitz, C.; Helmond, A.

    2013-01-01

    The paper examines Facebook’s ambition to extend into the entire web by focusing on social buttons and developing a medium-specific platform critique. It contextualises the rise of buttons and counters as metrics for user engagement and links them to different web economies. Facebook’s Like buttons

  6. Small punch tensile/fracture test data and 3D specimen surface data on Grade 91 ferritic/martensitic steel from cryogenic to room temperature.

    Science.gov (United States)

    Bruchhausen, Matthias; Lapetite, Jean-Marc; Ripplinger, Stefan; Austin, Tim

    2016-12-01

    Raw data from small punch tensile/fracture tests at two displacement rates in the temperature range from -196 °C to room temperature on Grade 91 ferritic/martensitic steel are presented. A number of specimens were analyzed after testing by means of X-ray computed tomography (CT). Based on the CT volume data detailed 3D surface maps of the specimens were established. All data are open access and available from Online Data Information Network (ODIN)https://odin.jrc.ec.europa.eu. The data presented in the current work has been analyzed in the research article "On the determination of the ductile to brittle transition temperature from small punch tests on Grade 91 ferritic-martensitic steel" (M. Bruchhausen, S. Holmström, J.-M. Lapetite, S. Ripplinger, 2015) [1].

  7. Evaluation of the tensile strength of the human ureter--preliminary results.

    Science.gov (United States)

    Shilo, Yaniv; Pichamuthu, Joseph E; Averch, Timothy D; Vorp, David A

    2014-12-01

    Ureteral injuries such as avulsion are directly related to mechanical damage of the ureter. Understanding the tensile strength of this tissue may assist in prevention of iatrogenic injuries. Few published studies have looked at the mechanical properties of the animal ureter and, of those, none has determined the tensile strength of the human ureter. Therefore, the purpose of this work was to determine the tensile strength of the human ureter. We harvested 11 human proximal ureters from patients who were undergoing nephrectomy for either kidney tumors or nonfunctioning kidney. The specimens were then cut into multiple circumferentially and longitudinally oriented tissue strips for tensile testing. Strips were uniaxially stretched to failure in a tensile testing machine. The corresponding force and displacement were recorded. Finally, stress at failure was noted as the tensile strength of the sample. Circumferential tensile strength was also compared in the proximal and distal regions of the specimens. The tensile strength of the ureter in circumferential and longitudinal orientations was found to be 457.52±33.74 Ncm(-2) and 902.43±122.08 Ncm(-2), respectively (Ptensile strength of the ureter was found to be significantly lower than the longitudinal strength. Circumferential tensile strength was also lower with more proximal parts of the ureter. This information may be important for the design of "intelligent" devices and simulators to prevent complications.

  8. Ingestion of six cylindrical and four button batteries

    DEFF Research Database (Denmark)

    Nielsen, Simon U; Rasmussen, Morten; Hoegberg, Lotte C G

    2010-01-01

    We report a suicidal ingestion of six cylindrical and four button batteries, in combination with overdosed prescription medicine and smoking of cannabis.......We report a suicidal ingestion of six cylindrical and four button batteries, in combination with overdosed prescription medicine and smoking of cannabis....

  9. Effect of nickel plating upon tensile tests of uranium--0.75 titanium alloy

    International Nuclear Information System (INIS)

    Hemperly, V.C.

    1975-01-01

    Electrolytic-nickel-plated specimens of uranium-0.75 wt percent titanium alloy were tested in air at 20 and 100 percent relative humidities. Tensile-test ductility values were lowered by a high humidity and also by nickel plating alone. Baking the nickel-plated specimens did not eliminate the ductility degradation. Embrittlement because of nickel plating was also evident in tensile tests at -34 0 C. (U.S.)

  10. Influence of tensile stress on cavity growth in nickel under helium irradiation

    International Nuclear Information System (INIS)

    Kusanagi, Hideo; Hide, Koichiro; Takaku, Hiroshi

    1989-01-01

    The influence of tensile stress on cavity behavior in pure nickel under helium irradiation was investigated by in-situ observation using the transmission electron microscope (TEM) in which an ion gun is installed. Specimens were irradiated at 500 0 C with 20 keV helium in the TEM. The dose rate was about 10 14 He/cm 2 s, and the angle between the helium beam and the normal direction of the specimens was about 60 0 . The damage rate estimated by the E-DEP-1 code was about 0.6x10 -3 dpa/s at its peak position. The main results are as follows: (1) cavity nucleation was accelerated by applying tensile stress, and cavity size in stressed specimens was several times larger than that in stress-free specimens; (2) cavity density in the stressed specimen increased more rapidly than in the stress-free specimen, and then decreased by cavity coalescences; (3) depth of cavity nucleation in the stress-free specimen was about 160 nm, while that in the stressed specimen was about 320 nm; that is, cavities nucleated in deeper regions in the stressed specimen than in the stress-free specimen. This result indicates that helium atoms and vacancies can migrate into the deeper region by applying tensile stress. (4) The experimental results obtained in this study can be explained qualitatively by the mechanism that mobile dislocations drag He-V complexes to the deeper region. This implies that there are similar phenomena in the case of compressive stress. (orig.)

  11. Experimental Analysis of Tensile Mechanical Properties of Sprayed FRP

    Directory of Open Access Journals (Sweden)

    Zhao Yang

    2016-01-01

    Full Text Available To study the tensile mechanical properties of sprayed FRP, 13 groups of specimens were tested through uniaxial tensile experiments, being analyzed about stress-strain curve, tensile strength, elastic modulus, breaking elongation, and other mechanical properties. Influencing factors on tensile mechanical properties of sprayed FRP such as fiber type, resin type, fiber volume ratio, fiber length, and composite thickness were studied in the paper too. The results show that both fiber type and resin type have an obvious influence on tensile mechanical properties of sprayed FRP. There will be a specific fiber volume ratio for sprayed FRP to obtain the best tensile mechanical property. The increase of fiber length can lead to better tensile performance, while that of composite thickness results in property degradation. The study can provide reference to popularization and application of sprayed FRP material used in structure reinforcement.

  12. Influence of relative humidity on tensile and compressive creep of ...

    African Journals Online (AJOL)

    This paper presents an experimental study on the influence of ambient relative humidity on tensile creep of plain concrete amended with Ground Granulated Blast - furnace Slag and compares it with its influence on compressive creep. Tensile and compressive creep tests were carried out on concrete specimens of 34.49 ...

  13. Evaluation of the tensile strength of the human ureter - Preliminary results.

    Science.gov (United States)

    Shilo, Yaniv; Pichamuthu, Joseph E; Averch, Timothy D; Vorp, David A

    2014-09-15

    Introduction: Ureteral injuries such as avulsion are directly related to mechanical damage of the ureter. Understanding the tensile strength of this tissue may assist in prevention of iatrogenic injuries. Few published studies have looked at the mechanical properties of the animal ureter, and of those none have determined the tensile strength of the human ureter. Therefore, the purpose of this work was to determine the tensile strength of the human ureter. Materials and Methods: We harvested 11 human proximal ureters from patients who were undergoing nephrectomy for either kidney tumors or non-functioning kidney. The specimens were then cut into multiple circumferentially and longitudinally-oriented tissue strips for tensile testing. Strips were uniaxially stretched to failure in a tensile testing machine. The corresponding force and displacement were recorded. Finally, stress at failure was noted as the tensile strength of the sample. Circumferential tensile strength was also compared in the proximal and distal regions of the specimens. Results: The tensile strength of the ureter in circumferential and longitudinal orientations was found to be 457.52±33.74 Ncm-2 and 902.43±122.08 Ncm-2, respectively (ptensile strength of the ureter was found to be significantly lower than the longitudinal strength. Circumferential tensile strength was also lower with more proximal parts of the ureter. This information may be important for the design of "intelligent" devices and simulators in order to prevent complications.

  14. Ductility and failure behaviour of both unirradiated and irradiated zircaloy-4 cladding using plane strain tensile specimens

    International Nuclear Information System (INIS)

    Carassou, S.; Le Saux, M.; Pizzanelli, J.P.; Rabouille, O.; Averty, X.; Poussard, C.; Cazalis, B.; Desquines, J.; Bernaudat, C.

    2010-01-01

    In this work, eight PST (Plan Strain Tensile) tests machined from a Zircaloy-4 (Zy-4) cladding irradiated up to 5 annual cycles have been performed at 280, 350 and 480 Celsius degrees. The specimen displacements during the tests were filmed and digitally recorded to allow the use of a Digital Image Correlation (DIC) analysis technique to experimentally determine the local strains on the outer surface of the specimens. The plane strain conditions have been verified and prevail over a wide area between the notches of the specimen, as expected from full 3D FE numerical analysis performed in support of the tests. For the first time, the location of the onset of fracture for this geometry on irradiated material has been experimentally observed: at 280 C.degrees, crack initiates in the vicinity of the notches, in an area where plane strain conditions are not fulfilled, and for a local circumferential strain value of about 5%. At 350 C. degrees and 480 C. degrees, cracks initiate at a location where plane strain conditions prevail, for circumferential strain values respectively close to 10% and greater than 50%. These results have been compared to results obtained previously by similar test on fresh and hydrided material, as well as tests performed as support to the study. At 350 C. degrees, the homogeneous 700 ppm hydrided Zy-4 and the Zy-4 irradiated during 5 annual cycles exhibit similar fracture behaviour, for both fracture hoop strain values (10%) and fracture mode (through-wall slant fracture). For the irradiated material, it has clearly been established that at 350 C. degrees, a brittle fracture occurs at the outer surface in the hydride rim. The crack propagates subsequently toward the inner surface and the notches, where final fracture occurs

  15. Load bearing and deformation behaviour of dynamically loaded wide plate specimens

    International Nuclear Information System (INIS)

    Julisch, P.; Haedrich, H.J.; Stadtmueller, W.; Sturm, D.

    1989-01-01

    For the testing of large-scale specimens, a 12 MN-High Loading Rate Tensile Testing Machine was designed and built at MPA Stuttgart. The aim was to determine the influence of high loading rates on the stress and strain behaviour of unwelded and welded components of ferritic and austenitic materials. This new generation of testing machines is driven by a propellant charge, and generates a maximum tensile force of 12 MN with a piston velocity of 25 m/s after a stroke of 20 mm, or a maximum velocity of 60 m/s after a stroke of 400 mm. In a first test programme, welded and unwelded wide plate specimens made of material X 6 CrNi 18 11 were tested at room temperature with different strain rates from 10 -3 /s to 63/s. In addition to a description of the 12 MN-High Loading Rate Tensile Testing Machine, the results of the high loading rate tensile tests performed will be presented and compared with quasistatically tested wide plate specimens. (orig.)

  16. Investigation and microstructural analyses of massive LSP impacts with coverage area on crack initiation location and tensile properties of AM50 magnesium alloy

    Energy Technology Data Exchange (ETDEWEB)

    Luo, K.Y.; Wang, C.Y. [School of Mechanical Engineering, Jiangsu University, Zhenjiang 212013 (China); Sun, G.F. [School of Mechanical Engineering, Southeast University, Nanjing 211189 (China); Cui, C.Y.; Sheng, J. [School of Mechanical Engineering, Jiangsu University, Zhenjiang 212013 (China); Lu, J.Z., E-mail: blueesky2005@163.com [School of Mechanical Engineering, Jiangsu University, Zhenjiang 212013 (China)

    2016-01-05

    The influence of massive laser shock peening (LSP) impacts with coverage area on tensile properties of AM50 magnesium alloy was investigated using MTS880-10 servo-hydraulic material testing machine system. Microstructure in the surface layer and fracture morphologies of as-machined and LSPed tensile specimens were also characterized and analyzed by scanning electron microscopy (SEM), transmission electron microscopy (TEM) and cross-sectional optical microscopy (OM). Special attention is paid to the crack initiation location as a function of LSPed coverage area in the gauge part of tensile specimen. Experimental results and analysis indicate that coverage area significantly influenced tensile properties of the tensile specimen. In addition, the grain refinement process in the top surface layer of AM50 magnesium alloy caused by massive LSP impacts is presented. Furthermore, the underlying influence mechanism of LSPed coverage area on tensile properties and crack initiation location of tensile specimen was clearly revealed.

  17. Investigation and microstructural analyses of massive LSP impacts with coverage area on crack initiation location and tensile properties of AM50 magnesium alloy

    International Nuclear Information System (INIS)

    Luo, K.Y.; Wang, C.Y.; Sun, G.F.; Cui, C.Y.; Sheng, J.; Lu, J.Z.

    2016-01-01

    The influence of massive laser shock peening (LSP) impacts with coverage area on tensile properties of AM50 magnesium alloy was investigated using MTS880-10 servo-hydraulic material testing machine system. Microstructure in the surface layer and fracture morphologies of as-machined and LSPed tensile specimens were also characterized and analyzed by scanning electron microscopy (SEM), transmission electron microscopy (TEM) and cross-sectional optical microscopy (OM). Special attention is paid to the crack initiation location as a function of LSPed coverage area in the gauge part of tensile specimen. Experimental results and analysis indicate that coverage area significantly influenced tensile properties of the tensile specimen. In addition, the grain refinement process in the top surface layer of AM50 magnesium alloy caused by massive LSP impacts is presented. Furthermore, the underlying influence mechanism of LSPed coverage area on tensile properties and crack initiation location of tensile specimen was clearly revealed.

  18. Relationship between surface area for adhesion and tensile bond strength--evaluation of a micro-tensile bond test.

    Science.gov (United States)

    Sano, H; Shono, T; Sonoda, H; Takatsu, T; Ciucchi, B; Carvalho, R; Pashley, D H

    1994-07-01

    The purpose of this study was to test the null hypothesis that there is no relationship between the bonded surface area of dentin and the tensile strength of adhesive materials. The enamel was removed from the occlusal surface of extracted human third molars, and the entire flat surface was covered with resin composite bonded to the dentin to form a flat resin composite crown. Twenty-four hours later, the bonded specimens were sectioned parallel to the long axis of the tooth into 10-20 thin sections whose upper part was composed of resin composite with the lower half being dentin. These small sections were trimmed using a high speed diamond bur into an hourglass shape with the narrowest portion at the bonded interface. Surface area was varied by altering the specimen thickness and width. Tensile bond strength was measured using custom-made grips in a universal testing machine. Tensile bond strength was inversely related to bonded surface area. At surface areas below 0.4 mm2, the tensile bond strengths were about 55 MPa for Clearfil Liner Bond 2 (Kuraray Co., Ltd.), 38 MPa for Scotchbond MP (3M Dental Products), and 20 MPa for Vitremer (3M Dental Products). At these small surface areas all of the bond failures were adhesive in nature. This new method permits measurement of high bond strengths without cohesive failure of dentin. It also permits multiple measurements to be made within a single tooth.

  19. The effect of alkaline treatment on tensile properties of sugar palm fibre reinforced epoxy composites

    International Nuclear Information System (INIS)

    Bachtiar, D.; Sapuan, S.M.; Hamdan, M.M.

    2008-01-01

    A study on the effect of alkaline treatment on tensile properties of sugar palm fibre reinforced epoxy composites is presented in this paper. The treatment was carried out using sodium hydroxide (NaOH) solutions at two different concentrations and three different soaking times. The hydrophilic nature of sugar palm fibre makes it difficult to adhere to hydrophobic epoxy and therefore posed the problem of interfacial bonding between fibre and matrix and such treatment was needed to alleviate such problem. The composite specimens were tested for tensile property determination. Some fractured specimens were examined under scanning electron microscope (SEM) to study the microstructure of the materials. Inconsistent results were obtained for tensile strengths, which indicate that the treatment is not very effective yet to improve the interfacial bonding. However, for tensile modulus, the results are much higher than untreated fibre composite specimens, which proved the effectiveness of the treatment

  20. Surface, structural and tensile properties of proton beam irradiated zirconium

    Energy Technology Data Exchange (ETDEWEB)

    Rafique, Mohsin; Chae, San; Kim, Yong-Soo, E-mail: yongskim@hanyang.ac.kr

    2016-02-01

    This paper reports the surface, structural and tensile properties of proton beam irradiated pure zirconium (99.8%). The Zr samples were irradiated by 3.5 MeV protons using MC-50 cyclotron accelerator at different doses ranging from 1 × 10{sup 13} to 1 × 10{sup 16} protons/cm{sup 2}. Both un-irradiated and irradiated samples were characterized using Field Emission Scanning Electron Microscope (FESEM), X-ray Diffraction (XRD) and Universal Testing Machine (UTM). The average surface roughness of the specimens was determined by using Nanotech WSxM 5.0 develop 7.0 software. The FESEM results revealed the formation of bubbles, cracks and black spots on the samples’ surface at different doses whereas the XRD results indicated the presence of residual stresses in the irradiated specimens. Williamson–Hall analysis of the diffraction peaks was carried out to investigate changes in crystallite size and lattice strain in the irradiated specimens. The tensile properties such as the yield stress, ultimate tensile stress and percentage elongation exhibited a decreasing trend after irradiation in general, however, an inconsistent behavior was observed in their dependence on proton dose. The changes in tensile properties of Zr were associated with the production of radiation-induced defects including bubbles, cracks, precipitates and simultaneous recovery by the thermal energy generated with the increase of irradiation dose.

  1. Surface, structural and tensile properties of proton beam irradiated zirconium

    Science.gov (United States)

    Rafique, Mohsin; Chae, San; Kim, Yong-Soo

    2016-02-01

    This paper reports the surface, structural and tensile properties of proton beam irradiated pure zirconium (99.8%). The Zr samples were irradiated by 3.5 MeV protons using MC-50 cyclotron accelerator at different doses ranging from 1 × 1013 to 1 × 1016 protons/cm2. Both un-irradiated and irradiated samples were characterized using Field Emission Scanning Electron Microscope (FESEM), X-ray Diffraction (XRD) and Universal Testing Machine (UTM). The average surface roughness of the specimens was determined by using Nanotech WSxM 5.0 develop 7.0 software. The FESEM results revealed the formation of bubbles, cracks and black spots on the samples' surface at different doses whereas the XRD results indicated the presence of residual stresses in the irradiated specimens. Williamson-Hall analysis of the diffraction peaks was carried out to investigate changes in crystallite size and lattice strain in the irradiated specimens. The tensile properties such as the yield stress, ultimate tensile stress and percentage elongation exhibited a decreasing trend after irradiation in general, however, an inconsistent behavior was observed in their dependence on proton dose. The changes in tensile properties of Zr were associated with the production of radiation-induced defects including bubbles, cracks, precipitates and simultaneous recovery by the thermal energy generated with the increase of irradiation dose.

  2. Tensile and charpy impact properties of irradiated reduced-activation ferritic steels

    Energy Technology Data Exchange (ETDEWEB)

    Klueh, R.L.; Alexander, D.J. [Oak Ridge National Lab., TN (United States)

    1996-10-01

    Tensile tests were conducted on eight reduced-activation Cr-W steels after irradiation to 15-17 and 26-29 dpa, and Charpy impact tests were conducted on the steels irradiated to 26-29 dpa. Irradiation was in the Fast Flux Test Facility at 365{degrees}C on steels containing 2.25-12% Cr, varying amounts of W, V, and Ta, and 0.1%C. Previously, tensile specimens were irradiated to 6-8 dpa and Charpy specimens to 6-8, 15-17, and 20-24 dpa. Tensile and Charpy specimens were also thermally aged to 20000 h at 365{degrees}C. Thermal aging had little effect on the tensile behavior or the ductile-brittle transition temperature (DBTT), but several steels showed a slight increase in the upper-shelf energy (USE). After {approx}7 dpa, the strength of the steels increased and then remained relatively unchanged through 26-29 dpa (i.e., the strength saturated with fluence). Post-irradiation Charpy impact tests after 26-29 dpa showed that the loss of impact toughness, as measured by an increase in DBTT and a decrease in the USE, remained relatively unchanged from the values after 20-24 dpa, which had been relatively unchanged from the earlier irradiations. As before, the two 9Cr steels were the most irradiation resistant.

  3. Influence of sodium evnironment on the uniaxial tensile behavior of titanium modified type 316 stainless steel

    International Nuclear Information System (INIS)

    Natesan, K.; Chopra, O.K.; Kassner, T.F.

    1978-01-01

    True stress-true strain tensile data have been obtained for titanium modified type 316 stainless steel in the solution annealed condition and after exposure to a flowing sodium environment at temperature of 700, 650, 600 and 550 0 C. The specimens were exposed to sodium for times between 120 and 5012 h to produce carbon penetration depths in the range 0.05-0.30 mm. The Voce equation was used to describe tensile flow curves for plastic strains above 0.005. The results showed that, when compared with solution annealed specimens, the tensile flow behavior of the sodium exposed specimens is characterized by a higher strain hardening rate, which decreases rapidly as the flow stress increases. The loss in tensile ductility of the material due to carburization in sodium environment was found to be minimal. (Auth.)

  4. In situ tensile testing of individual Co nanowires inside a scanning electron microscope

    International Nuclear Information System (INIS)

    Zhang Dongfeng; Breguet, Jean-Marc; Clavel, Reymond; Phillippe, Laetitia; Utke, Ivo; Michler, Johann

    2009-01-01

    Uniaxial quasi-static tensile testing on individual nanocrystalline Co nanowires (NWs), synthesized by electrochemical deposition process (EDP) in porous templates, was performed inside a scanning electron microscope (SEM) using a microfabricated tensile stage consisting of a comb drive actuator and a clamped-clamped beam force sensor. A 'three-beam structure' was fabricated by focused ion beam induced deposition (FIBID) on the stage, from which the specimen elongation and the tensile force could be measured simultaneously from SEM images at high magnification. A novel strategy of modifying device topography, e.g. in the form of trenches and pillars, was proposed to facilitate in situ SEM pick-and-place nanomanipulation, which could achieve a high yield of about 80% and reduce the difficulties in specimen preparation for tensile testing at the nanoscale. The measured apparent Young's modulus (75.3 ± 14.6) GPa and tensile strength (1.6 ± 0.4) GPa are significantly lower than the bulk modulus and the theoretical strength of monocrystalline samples, respectively. This result is important for designing Co NW-based devices. The origins of these distinctions are discussed in terms of the stiffnesses of the soldering portions, specimen misalignment, microstructure of the NWs and the experimental measurement uncertainty.

  5. A cryogenic tensile testing apparatus for micro-samples cooled by miniature pulse tube cryocooler

    International Nuclear Information System (INIS)

    Chen, L B; Liu, S X; Gu, K X; Zhou, Y; Wang, J J

    2015-01-01

    This paper introduces a cryogenic tensile testing apparatus for micro-samples cooled by a miniature pulse tube cryocooler. At present, tensile tests are widely applied to measure the mechanical properties of materials; most of the cryogenic tensile testing apparatus are designed for samples with standard sizes, while for non-standard size samples, especially for microsamples, the tensile testing cannot be conducted. The general approach to cool down the specimens for tensile testing is by using of liquid nitrogen or liquid helium, which is not convenient: it is difficult to keep the temperature of the specimens at an arbitrary set point precisely, besides, in some occasions, liquid nitrogen, especially liquid helium, is not easily available. To overcome these limitations, a cryogenic tensile testing apparatus cooled by a high frequency pulse tube cryocooler has been designed, built and tested. The operating temperatures of the developed tensile testing apparatus cover from 20 K to room temperature with a controlling precision of ±10 mK. The apparatus configurations, the methods of operation and some cooling performance will be described in this paper. (paper)

  6. Repair of Double Head Pectoralis Major Tendon Avulsion into its Native Footprint Using Bi-cortical EndoButtons and Tendon Sliding Technique.

    Science.gov (United States)

    Prabhu, Jagadish; Faqi, Mohammed Khalid; Alkhalifa, Fahad; Tayara, Bader Kamal; Awad, Rashad Khamis

    2017-01-01

    Injuries to the pectoralis major muscle are relatively infrequent. The mechanism of injury is usually an eccentric shortening of the pectoralis major under heavy load, such as when performing a bench press exercise. We report a case that presented to us with a history of sudden pain in the left pectoral region while doing heavy bench press exercise. The patient sustained a type III D pectoralis muscle -tendon avulsion. Surgical repair was done through a bi-cortical tendon sliding technique using two cortical buttons. In this article we describe our modifications to the previously described surgical technique for the pectoralis major tendon repair using the EndoButton and tension - slide technique, aiming to overcome the possible complications.

  7. Comparative evaluation of tensile bond strength of silicone-based denture liners after thermocycling and surface treatment.

    Science.gov (United States)

    Kaur, Harsimran; Datta, Kusum

    2015-01-01

    To examine, evaluate, and compare the tensile bond strength of two silicone-based liners; one autopolymerizing and one heat cured, when treated with different chemical etchants to improve their adhesion with denture base resin. Hundred and sixty test specimens of heat-cured polymethyl methacrylate (PMMA) were fabricated; out of which 80 specimens were tested for tensile bond strength after bonding it to autopolymerizing resilient liner (Ufigel P) and rest 80 to heat-cured resilient liner (Molloplast B). Each main group was further divided into four subgroups of 20 specimens each, one to act as a control and three were subjected to surface treatment with different chemical etchants namely dichloromethane, MMA monomer, and chloroform. The two silicone-based denture liners were processed between 2 PMMA specimens (10 mm × 10 mm × 40 mm) in the space provided by a spacer of 3 mm, thermocycled (5-55°C) for 500 cycles, and then their tensile strength measurements were done in the universal testing machine. One-way ANOVA technique showed a highly significant difference in the mean tensile bond strength values for all the groups. The Student's t-test computed values of statistics for the compared groups were greater than the critical values both at 5% and at 1% levels. Surface treatment of denture base resin with chemical etchants prior to the application of silicone-based liner (Ufigel P and Molloplast-B) increased the tensile bond strength. The increase was the highest with specimens subjected to 180 s of MMA surface treatment and the lowest with control group specimens.

  8. Squeeze casting of aluminum alloy A380: Microstructure and tensile behavior

    Directory of Open Access Journals (Sweden)

    Li Fang

    2015-09-01

    Full Text Available A380 alloy with a relatively thick cross-section of 25 mm was squeeze cast using a hydraulic press with an applied pressure of 90 MPa. Microstructure and tensile properties of the squeeze cast A380 were characterized and evaluated in comparison with the die cast counterpart. Results show that the squeeze cast A380 possesses a porosity level much lower than the die cast alloy, which is disclosed by both optical microscopy and the density measurement technique. The results of tensile testing indicate the improved tensile properties, specifically ultimate tensile strength (UTS: 215.9 MPa and elongation (Ef: 5.4%, for the squeeze cast samples over those of the conventional high-pressure die cast part (UTS: 173.7 MPa, Ef: 1.0%. The analysis of tensile behavior shows that the squeeze cast A380 exhibits a high tensile toughness (8.5 MJ·m-3 and resilience (179.3 kJ·m-3 compared with the die cast alloy (toughness: 1.4 MJ·m-3, resilience: 140.6 kJ·m-3, despite that, during the onset of plastic deformation, the strain-hardening rate of the die cast specimen is higher than that of the squeeze cast specimens. The microstructure analyzed by the scanning electron microscopy (SEM shows that both the squeeze and die cast specimens contain the primary α-Al, Al2Cu, Al5FeSi phase and the eutectic Si phase. But, the Al2Cu phase present in the squeeze cast alloy is relatively large in size and quantity. The SEM fractography evidently reveals the ductile fracture features of the squeeze cast A380 alloy.

  9. ASTM international symposium on small specimen test techniques and their applications to pressure vessel annealing and plant life extension

    International Nuclear Information System (INIS)

    Garner, F.A.; Hamilton, M.L.; Heinisch, H.L.; Kumar, A.S.

    1992-01-01

    Miniature sheet-type tensile specimens are currently being used in a variety of radiation damage studies conducted in a number of different reactors. Although these specimens are very small, they have proven successful in addressing issues encountered in both thermal reactors and anticipated fusion reactors. This paper reviews the results of a number of recent studies that illustrate the range of applicability of these small specimens. When combined with other types of specimens and other types of measurements made prior to tensile testing, miniature tensile specimens have been found to serve as very useful tools for application to both fundamental studies and alloy screening studies

  10. Effect of Thermal Cycling on the Tensile Behavior of Polymer Composites Reinforced by Basalt and Carbon Fibers

    Science.gov (United States)

    Khalili, S. Mohammad Reza; Najafi, Moslem; Eslami-Farsani, Reza

    2017-01-01

    The aim of the present work was to investigate the effect of thermal cycling on the tensile behavior of three types of polymer-matrix composites — a phenolic resin reinforced with woven basalt fibers, woven carbon fibers, and hybrid basalt and carbon fibers — in an ambient environment. For this purpose, tensile tests were performed on specimens previously subjected to a certain number of thermal cycles. The ultimate tensile strength of the specimen reinforced with woven basalt fibers had by 5% after thermal cycling, but the strength of the specimen with woven carbon fibers had reduced to a value by 11% higher than that before thermal cycling.

  11. Assessment of margins in resection specimens for head and neck malignancies.

    Science.gov (United States)

    Janjua, Omer Sefvan; Ahmed, Waseem; Qureshi, Sana Mehmood; Khan, Tariq Sarfaraz; Ahmed, Ashfaq; Alamgir, Wajiha

    2013-04-01

    To determine the relative frequency of clear, close and involved margins in resection specimens for head and neck malignancies. An observational study. The Department of Oral and Maxillofacial Surgery, Armed Forces Institute of Dentistry, Rawalpindi and the Department of Histopathology, Armed Forces Institute of Pathology, Rawalpindi, from January 2008 to December 2010. Tumour registers and computer data bases in the department of Histopathology of Armed Forces Institute of Pathology, Rawalpindi, were analyzed for the cases of malignancies involving head and neck region that were sent for histopathological analysis after resection in the last three years. Histopathology reports were obtained. The data regarding age, gender, site, type of malignancy and margin status (clear, close or involved) was recorded on specially designed proformas for the study and later on analyzed by using SPSS version 17.0. Results were expressed. A total of 319 cases were registered in the study duration. The age of the patients ranged from 22-90 years (mean 59.5 + 14.1 years). Male to female ratio was 1.53:1. One hundred and thirty six (42.6%) were squamous cell carcinoma (SCC), 163 were basal cell carcinomas (BCC, 51.0%); the rest included 18 salivary gland malignancies (5.7%) and one carcino-sarcoma (0.31%) and chondrosarcoma each. All margins were found clear in 137 patients (42.9%); involved in 168 cases (52.7%) and close in 14 cases (4.4%). Margin clearance could not be achieved in more than 50% cases, this can lead to poor prognosis. Hence, methods should be adopted to improve the margin clearance in various head and neck malignancies.

  12. Assessment of margins in resection specimens for head and neck malignancies

    International Nuclear Information System (INIS)

    Janjua, O. S.; Ahmed, W.; Ahmed, A.; Qureshi, S. M.; Khan, T. S.; Alamgir, W.

    2013-01-01

    Objective: To determine the relative frequency of clear, close and involved margins in resection specimens for head and neck malignancies. Study Design: An observational study. Place and Duration of Study: The Department of Oral and Maxillofacial Surgery, Armed Forces Institute of Dentistry, Rawalpindi and the Department of Histopathology, Armed Forces Institute of Pathology, Rawalpindi, from January 2008 to December 2010. Methodology: Tumour registers and computer data bases in the department of Histopathology of Armed Forces Institute of Pathology, Rawalpindi, were analyzed for the cases of malignancies involving head and neck region that were sent for histopathological analysis after resection in the last three years. Histopathology reports were obtained. The data regarding age, gender, site, type of malignancy and margin status (clear, close or involved) was recorded on specially designed proformas for the study and later on analyzed by using SPSS version 17.0. Results were expressed. Results: A total of 319 cases were registered in the study duration. The age of the patients ranged from 22 - 90 years (mean 59.5 + 14.1 years). Male to female ratio was 1.53:1. One hundred and thirty six (42.6%) were squamous cell carcinoma (SCC), 163 were basal cell carcinomas (BCC, 51.0%); the rest included 18 salivary gland malignancies (5.7%) and one carcino-sarcoma (0.31%) and chondrosarcoma each. All margins were found clear in 137 patients (42.9%); involved in 168 cases (52.7%) and close in 14 cases (4.4%). Conclusion: Margin clearance could not be achieved in more than 50% cases, this can lead to poor prognosis. Hence, methods should be adopted to improve the margin clearance in various head and neck malignancies. (author)

  13. Effect of elevated temperature on the tensile strength of Napier/glass-epoxy hybrid reinforced composites

    Science.gov (United States)

    Ridzuan, M. J. M.; Majid, M. S. Abdul; Afendi, M.; Firdaus, A. Z. Ahmad; Azduwin, K.

    2017-11-01

    The effects of elevated temperature on the tensile strength of Napier/glass-epoxy hybrid reinforced composites and its morphology of fractured surfaces are discussed. Napier/glass-epoxy hybrid reinforced composites were fabricated by using vacuum infusion method by arranging Napier fibres in between sheets of woven glass fibres. Napier and glass fibres were laminated with estimated volume ratios were 24 and 6 vol. %, respectively. The epoxy resin was used as matrix estimated to 70 vol. %. Specimens were tested to failure under tension at a cross-head speed of 1 mm/min using Universal Testing Machine (Instron) with a load cell 100 kN at four different temperatures of RT, 40°C, 60°C and 80°C. The morphology of fractured surface of hybrid composites was investigated by field emission scanning electron microscopy. The result shows reduction in tensile strength at elevated temperatures. The increase in the temperature activates the process of diffusion, and generates critical stresses which cause the damage at first-ply or at the centre of the hybrid plate, as a result lower the tensile strength. The observation of FESEM images indicates that the fracture mode is of evolution of localized damage, from fibre/matrix debonding, matric cracking, delamination and fibre breakage.

  14. Tensile properties of V-5Cr-5Ti alloy after exposure in air environment

    Energy Technology Data Exchange (ETDEWEB)

    Natesan, K.; Soppet, W.K. [Argonne National Lab., IL (United States)

    1997-04-01

    Oxidation studies were conducted on V-5Cr-5Ti alloy specimens in an air environment to evaluate the oxygen uptake behavior of the alloy as a function of temperature and exposure time. The oxidation rates, calculated from parabolic kinetic measurements of thermogravimetric testing and confirmed by microscopic analysis of cross sections of exposed specimens, were 5, 17, and 27 {mu}m per year after exposure at 300, 400, and 500{degrees}C, respectively. Uniaxial tensile tests were conducted at room temperature and at 500{degrees}C on preoxidized specimens of the alloy to examine the effects of oxidation and oxygen migration on tensile strength and ductility. Correlations were developed between tensile strength and ductility of the oxidized alloy and microstructural characteristics such as oxide thickness, depth of hardened layer, depth of intergranular fracture zone, and transverse crack length.

  15. Examining the influence of injection speed and mould temperature on the tensile strength of polypropylene and ABS

    DEFF Research Database (Denmark)

    Aarøe, Esben Raahede; Blaimschein, Karl Stephan; Deker, Lasse

    This report is the final task of course “41738 Experimental Plastics Technology” in the three weeks period of June 2009 at DTU, IPL. The aim of this project has been to investigate the ultimate tensile strength behaviour of two different polymers, with different structural composition, by varying...... the injection speed and the mold temperature independently while keeping all other process parameters fixed. In addition the scaling from production of large to small geometries has been investigated by doing two parallel productions and test setups of respectively injection moulded and micro injection moulded...... specimens. After production and tensile testing the specimens were examined with a microscope to underpin conclusions from the tensile test data. It was experienced that the injection speed in general increased the the tensile strength by orienting the polymeric-chains lengthwise in the specimens and thus...

  16. A fast button surface defects detection method based on convolutional neural network

    Science.gov (United States)

    Liu, Lizhe; Cao, Danhua; Wu, Songlin; Wu, Yubin; Wei, Taoran

    2018-01-01

    Considering the complexity of the button surface texture and the variety of buttons and defects, we propose a fast visual method for button surface defect detection, based on convolutional neural network (CNN). CNN has the ability to extract the essential features by training, avoiding designing complex feature operators adapted to different kinds of buttons, textures and defects. Firstly, we obtain the normalized button region and then use HOG-SVM method to identify the front and back side of the button. Finally, a convolutional neural network is developed to recognize the defects. Aiming at detecting the subtle defects, we propose a network structure with multiple feature channels input. To deal with the defects of different scales, we take a strategy of multi-scale image block detection. The experimental results show that our method is valid for a variety of buttons and able to recognize all kinds of defects that have occurred, including dent, crack, stain, hole, wrong paint and uneven. The detection rate exceeds 96%, which is much better than traditional methods based on SVM and methods based on template match. Our method can reach the speed of 5 fps on DSP based smart camera with 600 MHz frequency.

  17. Estimation of tensile force in the hamstring muscles during overground sprinting.

    Science.gov (United States)

    Ono, T; Higashihara, A; Shinohara, J; Hirose, N; Fukubayashi, T

    2015-02-01

    The purpose of this study was to identify the period of the gait cycle during which the hamstring muscles were likely injured by estimating the magnitude of tensile force in each muscle during overground sprinting. We conducted three-dimensional motion analysis of 12 male athletes performing overground sprinting at their maximal speed and calculated the hamstring muscle-tendon length and joint angles of the right limb throughout a gait cycle during which the ground reaction force was measured. Electromyographic activity during sprinting was recorded for the biceps femoris long head, semitendinosus, and semimembranosus muscles of ipsilateral limb. We estimated the magnitude of tensile force in each muscle by using the length change occurred in the musculotendon and normalized electromyographic activity value. The study found a quick increase of estimated tensile force in the biceps femoris long head during the early stance phase of the gait cycle during which the increased hip flexion angle and ground reaction force occurred at the same time. This study provides quantitative data of tensile force in the hamstring muscles suggesting that the biceps femoris long head muscle is susceptible to a strain injury during the early stance phase of the sprinting gait cycle. © Georg Thieme Verlag KG Stuttgart · New York.

  18. Comparative evaluation of tensile bond strength of silicone-based denture liners after thermocycling and surface treatment

    Directory of Open Access Journals (Sweden)

    Harsimran Kaur

    2015-01-01

    Full Text Available Purpose: To examine, evaluate, and compare the tensile bond strength of two silicone-based liners; one autopolymerizing and one heat cured, when treated with different chemical etchants to improve their adhesion with denture base resin. Materials and Methods: Hundred and sixty test specimens of heat-cured polymethyl methacrylate (PMMA were fabricated; out of which 80 specimens were tested for tensile bond strength after bonding it to autopolymerizing resilient liner (Ufigel P and rest 80 to heat-cured resilient liner (Molloplast B. Each main group was further divided into four subgroups of 20 specimens each, one to act as a control and three were subjected to surface treatment with different chemical etchants namely dichloromethane, MMA monomer, and chloroform. The two silicone-based denture liners were processed between 2 PMMA specimens (10 mm × 10 mm × 40 mm in the space provided by a spacer of 3 mm, thermocycled (5-55°C for 500 cycles, and then their tensile strength measurements were done in the universal testing machine. Results: One-way ANOVA technique showed a highly significant difference in the mean tensile bond strength values for all the groups. The Student′s t-test computed values of statistics for the compared groups were greater than the critical values both at 5% and at 1% levels. Conclusion: Surface treatment of denture base resin with chemical etchants prior to the application of silicone-based liner (Ufigel P and Molloplast-B increased the tensile bond strength. The increase was the highest with specimens subjected to 180 s of MMA surface treatment and the lowest with control group specimens.

  19. The floor effect: impoverished spatial memory for elevator buttons.

    Science.gov (United States)

    Vendetti, Michael; Castel, Alan D; Holyoak, Keith J

    2013-05-01

    People typically remember objects to which they have frequently been exposed, suggesting that memory is a by-product of perception. However, prior research has shown that people have exceptionally poor memory for the features of some objects (e.g., coins) to which they have been exposed over the course of many years. Here, we examined how people remember the spatial layout of the buttons on a frequently used elevator panel, to determine whether physical interaction (rather than simple exposure) would ensure the incidental encoding of spatial information. Participants who worked in an eight-story office building displayed very poor recall for the elevator panel but above-chance performance on a recognition test. Performance was related to how often and how recently the person had used the elevator. In contrast to their poor memory for the spatial layout of the elevator buttons, most people readily recalled small distinctive graffiti on the elevator walls. In a more implicit test, the majority were able to locate their office floor and the eighth floor button when asked to point toward these buttons when in the actual elevator, with the button labels covered. However, identification was very poor for other floors (including the first floor), suggesting that even frequent interaction with information does not always lead to accurate spatial memory. These findings have implications for understanding the complex relationships among attention, expertise, and memory.

  20. Tensile and impact testing of an HFBR [High Flux Beam Reactor] control rod follower

    International Nuclear Information System (INIS)

    Czajkowski, C.J.; Schuster, M.H.; Roberts, T.C.; Milian, L.W.

    1989-08-01

    The Materials Technology Group of the Department of Nuclear Energy (DNE) at Brookhaven National Laboratory (BNL) undertook a program to machine and test specimens from a control rod follower from the High Flux Beam Reactor (HFBR). Tensile and Charpy impact specimens were machined and tested from non-irradiated aluminum alloys in addition to irradiated 6061-T6 from the HFBR. The tensile test results on irradiated material showed a two-fold increase in tensile strength to a maximum of 100.6 ksi. The impact resistance of the irradiated material showed a six-fold decrease in values (3 in-lb average) compared to similar non-irradiated material. Fracture toughness (K I ) specimens were tested on an unirradiated compositionally and dimensionally similar (to HFBR follower) 6061 T-6 material with K max values of 24.8 ± 1.0 Ksi√in (average) being obtained. The report concludes that the specimens produced during the program yielded reproducible and believable results and that proper quality assurance was provided throughout the program. 9 figs., 6 tabs

  1. Influence of Simulated Acid Rain Corrosion on the Uniaxial Tensile Mechanical Properties of Concrete

    Directory of Open Access Journals (Sweden)

    Ying-zi Zhang

    2012-01-01

    Full Text Available An experimental study on the uniaxial tensile property of concrete exposed to the acid rain environment was carried out. Acid rain with pH level of 1.0 was deposed by the mixture of sulfate and nitric acid solution in the laboratory. Dumbbell-shaped concrete specimens were immersed in the simulated acid rain completely. After being exposed to the deposed mixture for a certain period, uniaxial tensile test was performed on the concrete specimens. The results indicate that elastic modulus, tensile strength, and peak strain have a slight increase at the initial corrosion stage, and with the extension of corrosion process, elastic modulus and tensile strength decrease gradually, while the peak strain still increases. It is found that the compressive strength is more sensitive than the tensile strength in aggressive environment. Based on the experimental results, an equation was proposed to describe the ascending branch of the stress-strain curve of the concrete corroded by acid rain.

  2. Tensile and fracture behavior of polymer foams

    International Nuclear Information System (INIS)

    Kabir, Md. E.; Saha, M.C.; Jeelani, S.

    2006-01-01

    Tensile and mode-I fracture behavior of cross-linked polyvinyl chloride (PVC) and rigid polyurethane (PUR) foams are examined. Tension tests are performed using prismatic bar specimens and mode-I fracture tests are performed using single edge notched bend (SENB) specimens under three-point bending. Test specimens are prepared from PVC foams with three densities and two different levels of cross-linking, and PUR foam with one density. Tension and quasi-static fracture tests are performed using a Zwick/Rowell test machine. Dynamic fracture tests are performed using a DYNATUP model 8210 instrumented drop-tower test set up at three different impact energy levels. Various parameters such as specimen size, loading rate, foam density, cross-linking, crack length, cell orientation (flow and rise-direction) and solid polymer material are studied. It is found that foam density and solid polymer material have a significant effect on tensile strength, modulus, and fracture toughness of polymer foams. Level of polymer cross-linking is also found to have a significant effect on fracture toughness. The presence of cracks in the rise- and flow direction as well as loading rate has minimal effect. Dynamic fracture behavior is found to be different as compared to quasi-static fracture behavior. Dynamic fracture toughness (K d ) increases with impact energy. Examination of fracture surfaces reveals that the fracture occurs in fairly brittle manner for all foam materials

  3. Porosity Defect Remodeling and Tensile Analysis of Cast Steel

    Directory of Open Access Journals (Sweden)

    Linfeng Sun

    2016-02-01

    Full Text Available Tensile properties on ASTM A216 WCB cast steel with centerline porosity defect were studied with radiographic mapping and finite element remodeling technique. Non-linear elastic and plastic behaviors dependent on porosity were mathematically described by relevant equation sets. According to the ASTM E8 tensile test standard, matrix and defect specimens were machined into two categories by two types of height. After applying radiographic inspection, defect morphologies were mapped to the mid-sections of the finite element models and the porosity fraction fields had been generated with interpolation method. ABAQUS input parameters were confirmed by trial simulations to the matrix specimen and comparison with experimental outcomes. Fine agreements of the result curves between simulations and experiments could be observed, and predicted positions of the tensile fracture were found to be in accordance with the tests. Chord modulus was used to obtain the equivalent elastic stiffness because of the non-linear features. The results showed that elongation was the most influenced term to the defect cast steel, compared with elastic stiffness and yield stress. Additional visual explanations on the tensile fracture caused by void propagation were also given by the result contours at different mechanical stages, including distributions of Mises stress and plastic strain.

  4. Low temperature tensile properties and stress corrosion cracking resistance in the super duplex stainless steels weldments

    International Nuclear Information System (INIS)

    Lee, Jeung Woo; Sung, Jang Hyun; Lee, Sung Keun

    1998-01-01

    Low temperature tensile properties and SCC resistances of super duplex stainless steels and their weldments are investigated. Tensile strengths increase remarkably with decreasing test temperature, while elongations decrease steeply at -196 .deg. C after showing peak or constant value down to -100 .deg. C. Owing to the low tensile deformation of weld region, elongations of welded specimen decrease in comparison to those of unwelded specimen. The welded tensile specimen is fractured through weld region at -196 .deg. C due to the fact that the finely dispersed ferrite phase in the austenite matrix increases an opportunity to supply the crack propagation path through the brittle ferrite phase at low temperature. The stress corrosion cracking initiates preferentially at the surface ferrite phase of base metal region and propagates through ferrite phase. When the corrosion crack meets with the fibrously aligned austenite phase to the tensile direction, the ferrite phase around austenite continues to corrode. Eventually, fracture of the austenite phase begins without enduring the tensile load. The addition of Cu+W to the super duplex stainless steel deteriorates the SCC resistance in boiling MgCl 2 solution, possibly due to the increment of pits in the ferrite phase and reduction of N content in the austenite phase

  5. Tensile behavior and tension stiffening of reinforced concrete

    International Nuclear Information System (INIS)

    Choun, Young Sun; Seo, Jeong Moon

    2001-03-01

    For the ultimate behavior analysis of containment buildings under severe accident conditions, a clear understanding of tensile behaviors of plain and reinforced concrete is necessary. Nonlinear models for tensile behaviors of concrete are also needed. This report describe following items: tensile behaviors of plain concrete, test results of reinforced concrete panels in uniaxial and biaxial tension, tension stiffening. The tensile behaviors of reinforced concrete are significantly influenced by the properties of concrete and reinforcing steel. Thus, for a more reliable evaluation of tensile behavior and ultimate pressure capacity of a reinforced or prestressed concrete containment building, an advanced concrete model which can be considered rebar-concrete interaction effects should be developed. In additions, a crack behavior analysis method and tension stiffening models, which are based on fracture mechanics, should be developed. The model should be based on the various test data from specimens considering material and sectional properties of the containment building

  6. Vascular ring complicates accidental button battery ingestion.

    Science.gov (United States)

    Mercer, Ronald W; Schwartz, Matthew C; Stephany, Joshua; Donnelly, Lane F; Franciosi, James P; Epelman, Monica

    2015-01-01

    Button battery ingestion can lead to dangerous complications, including vasculoesophageal fistula formation. The presence of a vascular ring may complicate battery ingestion if the battery lodges at the level of the ring and its important vascular structures. We report a 4-year-old boy with trisomy 21 who was diagnosed with a vascular ring at the time of button battery ingestion and died 9 days after presentation due to massive upper gastrointestinal bleeding from esophageal erosion and vasculoesophageal fistula formation. Copyright © 2015 Elsevier Inc. All rights reserved.

  7. Tensile and fracture toughness test results of neutron irradiated beryllium

    Energy Technology Data Exchange (ETDEWEB)

    Chaouadi, R.; Moons, F.; Puzzolante, J.L. [Centre d`Etude de l`Energie Nucleaire, Mol (Belgium)

    1998-01-01

    Tensile and fracture toughness test results of four Beryllium grades are reported here. The flow and fracture properties are investigated by using small size tensile and round compact tension specimens. Irradiation was performed at the BR2 material testing reactor which allows various temperature and irradiation conditions. The fast neutron fluence (>1 MeV) ranges between 0.65 and 2.45 10{sup 21} n/cm{sup 2}. In the meantime, un-irradiated specimens were aged at the irradiation temperatures to separate if any the effect of temperature from irradiation damage. Test results are analyzed and discussed, in particular in terms of the effects of material grade, test temperature, thermal ageing and neutron irradiation. (author)

  8. Additive Manufacturing of Syntactic Foams: Part 2: Specimen Printing and Mechanical Property Characterization

    Science.gov (United States)

    Singh, Ashish Kumar; Saltonstall, Brooks; Patil, Balu; Hoffmann, Niklas; Doddamani, Mrityunjay; Gupta, Nikhil

    2018-03-01

    High-density polyethylene (HDPE) and its fly ash cenosphere-filled syntactic foam filaments have been recently developed. These filaments are used for three-dimensional (3D) printing using a commercial printer. The developed syntactic foam filament (HDPE40) contains 40 wt.% cenospheres in the HDPE matrix. Printing parameters for HDPE and HDPE40 were optimized for use in widely available commercial printers, and specimens were three-dimensionally (3D) printed for tensile testing at strain rate of 10-3 s-1. Process optimization resulted in smooth operation of the 3D printer without nozzle clogging or cenosphere fracture during the printing process. Characterization results revealed that the tensile modulus values of 3D-printed HDPE and HDPE40 specimens were higher than those of injection-molded specimens, while the tensile strength was comparable, but the fracture strain and density were lower.

  9. Tensile bond strength of metal bracket bonding to glazed ceramic surfaces with different surface conditionings.

    Science.gov (United States)

    Akhoundi, Ms Ahmad; Kamel, M Rahmati; Hashemi, Sh Mahmood; Imani, M

    2011-01-01

    The objective of this study was to compare the tensile bond strength of metal brackets bonding to glazed ceramic surfaces using three various surface treatments. Forty two glazed ceramic disks were assigned to three groups. In the first and second groups the specimens were etched with 9.5% hydrofluoric acid (HFA). Subsequently in first group, ceramic primer and adhesive were applied, but in second group a bonding agent alone was used. In third group, specimens were treated with 35% phosphoric acid followed by ceramic primer and adhesive application. Brackets were bonded with light cure composites. The specimens were stored in distilled water in the room temperature for 24 hours and thermocycled 500 times between 5°C and 55°C. The universal testing machine was used to test the tensile bond strength and the adhesive remenant index scores between three groups was evaluated. The data were subjected to one-way ANOVA, Tukey and Kruskal-Wallis tests respectively. The tensile bond strength was 3.69±0.52 MPa forfirst group, 2.69±0.91 MPa for second group and 3.60±0.41 MPa for third group. Group II specimens showed tensile strength values significantly different from other groups (Ptensile bond strength.

  10. Closeout of JOYO-1 Specimen Fabrication Efforts

    International Nuclear Information System (INIS)

    ME Petrichek; JL Bump; RF Luther

    2005-01-01

    Fabrication was well under way for the JOYO biaxial creep and tensile specimens when the NR Space program was canceled. Tubes of FS-85, ASTAR-811C, and T-111 for biaxial creep specimens had been drawn at True Tube (Paso Robles, CA), while tubes of Mo-47.5 Re were being drawn at Rhenium Alloys (Cleveland, OH). The Mo-47.5 Re tubes are now approximately 95% complete. Their fabrication and the quantities produced will be documented at a later date. End cap material for FS-85, ASTAR-811C, and T-111 had been swaged at Pittsburgh Materials Technology, Inc. (PMTI) (Large, PA) and machined at Vangura (Clairton, PA). Cutting of tubes, pickling, annealing, and laser engraving were in process at PMTI. Several biaxial creep specimen sets of FS-85, ASTAR-811C, and T-111 had already been sent to Pacific Northwest National Laboratory (PNNL) for weld development. In addition, tensile specimens of FS-85, ASTAR-811C, T-111, and Mo-47.5 Re had been machined at Kin-Tech (North Huntington, PA). Actual machining of the other specimen types had not been initiated. Flowcharts 1-3 detail the major processing steps each piece of material has experienced. A more detailed description of processing will be provided in a separate document [B-MT(SRME)-51]. Table 1 lists the in-process materials and finished specimens. Also included are current metallurgical condition of these materials and specimens. The available chemical analyses for these alloys at various points in the process are provided in Table 2

  11. Tensile properties of Zr-2.5 Nb pressure tube alloy between 25 and 800 degC

    International Nuclear Information System (INIS)

    Singh, R.N.; Kishore, R.; Sinha, T.K.; Banerjee, S.

    2000-10-01

    Tensile properties of zirconium-2.5 wt. % niobium pressure tube material were evaluated by uniaxial tension tests at temperatures between 25 and 800 degC and under strain-rates varying from 3.3 x 10 -5 to 3.3 x 10 -3 /s. Tests were carried out on specimens fabricated from the sections of finished (autoclaved) tubes as well as on those machined from the sections of cold worked (2 nd pilgered) tubes. Moreover, specimens fabricated from finished tubes belonging to twenty different heats were tested at 300 degC to study the heat to heat variation in tensile properties of this alloy. In order to study the effect of the crystallographic texture on the tensile properties, specimens oriented in longitudinal as well as, in transverse directions of the tubes were also tested. Results showed that both yield and ultimate tensile strengths of this alloy decreased monotonically with increasing test temperatures, with a rapid fall in strengths above a temperature of 350 degC (623 K). The tensile ductility did not change appreciably up to 400 degC (673K) but increased rapidly above this temperature. The observed results on the temperature dependence of the strength and ductility indicated the possible occurrence of dynamic strain-ageing in this alloy in the temperature range of 200-300 degC (473 to 573 K). The transverse specimens showed higher strengths and lower ductility as compared to those of the longitudinal specimens up to a temperature of 350 degC (623 K). Above 350 degC, the difference in the strengths and the ductility of the two types of the specimens, became negligibly small indicating that the texture did not appreciably influence the tensile properties of this alloy at temperatures exceeding 350 degC. The alloy developed extensive superplasticity (ductility exceeding 100 %), when tested in the temperature range of 650-800 degC. Maximum ductility values of 650 % for longitudinal and 900 % for the transverse orientation with strain-rate sensitivity (m) exceeding 0

  12. Thermocron iButton and iBBat temperature dataloggers emit ultrasound.

    Science.gov (United States)

    Willis, Craig K R; Jameson, Joel W; Faure, Paul A; Boyles, Justin G; Brack, Virgil; Cervone, Tom H

    2009-10-01

    Thermocron iButton dataloggers are widely used to measure thermal microclimates experienced by wild animals. The iBBat is a smaller version of the datalogger, also commercially available, that is used to measure animal skin or core body temperatures when attached externally or surgically implanted. Field observations of bats roosting under a bridge suggested that bats avoided locations with iButtons. A heterodyne bat detector revealed that the dataloggers emitted ultrasound which was detectable from a distance of up to 30 cm. We therefore recorded and quantified the acoustic properties [carrier frequency (Hz) and root mean square sound pressure level (dB SPL)] of iButton and iBBat dataloggers. All units emitted a 32.9 kHz pure tone that was readily picked up with a time expansion bat detector at a distance of 1 cm, and most were detected at a distance of 15 cm. The maximum amplitude of iButton dataloggers was 46.5 dB SPL at 1.0 cm-a level within the range of auditory sensitivity for most small mammals. Wrapping iButtons in plastic insulation severely attenuated the amplitude of ultrasound. Although there was a statistically significant reduction in rates of warming and cooling with insulation, this effect was small and we suggest that insulation may be a viable solution to eliminate unwanted ultrasonic noise in instances when small delays in thermal response dynamics are not a concern. We recommend behavioural studies to assess if the electronic signals emitted by iButtons are disturbing to small mammals.

  13. Effects of soldering methods on tensile strength of a gold-palladium metal ceramic alloy.

    Science.gov (United States)

    Ghadhanfari, Husain A; Khajah, Hasan M; Monaco, Edward A; Kim, Hyeongil

    2014-10-01

    The tensile strength obtained by conventional postceramic application soldering and laser postceramic welding may require more energy than microwave postceramic soldering, which could provide similar tensile strength values. The purpose of the study was to compare the tensile strength obtained by microwave postceramic soldering, conventional postceramic soldering, and laser postceramic welding. A gold-palladium metal ceramic alloy and gold-based solder were used in this study. Twenty-seven wax specimens were cast in gold-palladium noble metal and divided into 4 groups: laser welding with a specific postfiller noble metal, microwave soldering with a postceramic solder, conventional soldering with the same postceramic solder used in the microwave soldering group, and a nonsectioned control group. All the specimens were heat treated to simulate a normal porcelain sintering sequence. An Instron Universal Testing Machine was used to measure the tensile strength for the 4 groups. The means were analyzed statistically with 1-way ANOVA. The surface and fracture sites of the specimens were subjectively evaluated for fracture type and porosities by using a scanning electron microscope. The mean (standard deviation) ultimate tensile strength values were as follows: nonsectioned control 818 ±30 MPa, microwave 516 ±34 MPa, conventional 454 ±37 MPa, and laser weld 191 ±39 MPa. A 1-way ANOVA showed a significant difference in ultimate tensile strength among the groups (F3,23=334.5; Ptensile strength for gold and palladium noble metals than either conventional soldering or laser welding. Conventional soldering resulted in a higher tensile strength than laser welding. Under the experimental conditions described, either microwave or conventional postceramic soldering would appear to satisfy clinical requirements related to tensile strength. Copyright © 2014 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

  14. High temperature tensile testing of modified 9Cr-1Mo after irradiation with high energy protons

    International Nuclear Information System (INIS)

    Toloczko, M.B.; Hamilton, M.L.; Maloy, S.A.

    2003-01-01

    This study examines the effect of tensile test temperatures ranging from 50 to 600 deg. C on the tensile properties of a modified 9Cr-1Mo ferritic steel after high energy proton irradiation at about 35-67 deg. C to doses from 1 to 3 dpa and 9 dpa. For the specimens irradiated to doses between 1 and 3 dpa, it was observed that the yield strength and ultimate strength decreased monotonically as a function of tensile test temperature, whereas the uniform elongation (UE) remained at approximately 1% for tensile test temperatures up to 250 deg. C and then increased for tensile test temperatures up to and including 500 deg. C. At 600 deg. C, the UE was observed to be less than the values at 400 and 500 deg. C. UE of the irradiated material tensile tested at 400-600 deg. C was observed to be greater than the values for the unirradiated material at the same temperatures. Tensile tests on the 9 dpa specimens followed similar trends

  15. Development of Embedded EM Sensors for Estimating Tensile Forces of PSC Girder Bridges

    Science.gov (United States)

    Kim, Ju-Won; Lee, Chaggil; Park, Seunghee

    2017-01-01

    The tensile force of pre-stressed concrete (PSC) girders is the most important factor for managing the stability of PSC bridges. The tensile force is induced using pre-stressing (PS) tendons of a PSC girder. Because the PS tendons are located inside of the PSC girder, the tensile force cannot be measured after construction using conventional NDT (non-destructive testing) methods. To monitor the induced tensile force of a PSC girder, an embedded EM (elasto-magnetic) sensor was proposed in this study. The PS tendons are made of carbon steel, a ferromagnetic material. The magnetic properties of the ferromagnetic specimen are changed according to the induced magnetic field, temperature, and induced stress. Thus, the tensile force of PS tendons can be estimated by measuring their magnetic properties. The EM sensor can measure the magnetic properties of ferromagnetic materials in the form of a B (magnetic density)-H (magnetic force) loop. To measure the B-H loop of a PS tendon in a PSC girder, the EM sensor should be embedded into the PSC girder. The proposed embedded EM sensor can be embedded into a PSC girder as a sheath joint by designing screw threads to connect with the sheath. To confirm the proposed embedded EM sensors, the experimental study was performed using a down-scaled PSC girder model. Two specimens were constructed with embedded EM sensors, and three sensors were installed in each specimen. The embedded EM sensor could measure the B-H loop of PS tendons even if it was located inside concrete, and the area of the B-H loop was proportionally decreased according to the increase in tensile force. According to the results, the proposed method can be used to estimate the tensile force of unrevealed PS tendons. PMID:28867790

  16. Acromioclavicular joint dislocation: a Dog Bone button fixation alone versus Dog Bone button fixation augmented with acromioclavicular repair-a finite element analysis study.

    Science.gov (United States)

    Sumanont, Sermsak; Nopamassiri, Supachoke; Boonrod, Artit; Apiwatanakul, Punyawat; Boonrod, Arunnit; Phornphutkul, Chanakarn

    2018-03-20

    Suspension suture button fixation was frequently used to treat acromioclavicular joint (ACJ) dislocation. However, there were many studies reporting about complications and residual horizontal instability after fixation. Our study compared the stability of ACJ after fixation between coracoclavicular (CC) fixation alone and CC fixation combined with ACJ repair by using finite element analysis (FEA). A finite element model was created by using CT images from the normal shoulder. The model 1 was CC fixation with suture button alone, and the model 2 was CC fixation with suture button combined with ACJ repair. Three different forces (50, 100, 200 N) applied to the model in three planes; inferior, anterior and posterior direction load to the acromion. The von Mises stress of the implants and deformation at ACJs was recorded. The ACJ repair in the model 2 could reduce the peak stress on the implant after applying the loading forces to the acromion which the ACJ repair could reduce the peak stress of the FiberWire at suture button about 90% when compared to model 1. And, the ACJ repair could reduce the deformation of the ACJ after applying the loading forces to the acromion in both vertical and horizontal planes. This FEA supports that the high-grade injuries of the ACJ should be treated with CC fixation combined with ACJ repair because this technique provides excellent stability in both vertical and horizontal planes and reduces stress to the suture button.

  17. Results from a Test Fixture for button BPM Trapped Mode Measurements

    Energy Technology Data Exchange (ETDEWEB)

    Cameron,P.; Bacha, B.; Blednykh, A.; Pinayev, I.; Singh, O.

    2009-05-04

    A variety of measures have been suggested to mitigate the problem of button BPM trapped mode heating. A test fixture, using a combination of commercial-off-the-shelf and custom machined components, was assembled to validate the simulations. We present details of the fixture design, measurement results, and a comparison of the results with the simulations. A brief history of the trapped mode button heating problem and a set of design rules for BPM button optimization are presented elsewhere in these proceedings. Here we present measurements on a test fixture that was assembled to confirm, if possible, a subset of those rules: (1) Minimize the trapped mode impedance and the resulting power deposited in this mode by the beam. (2) Maximize the power re-radiated back into the beampipe. (3) Maximize electrical conductivity of the outer circumference of the button and minimize conductivity of the inner circumference of the shell, to shift power deposition from the button to the shell. The problem is then how to extract useful and relevant information from S-parameter measurements of the test fixture.

  18. Tensile strength of concrete under static and intermediate strain rates: Correlated results from different testing methods

    International Nuclear Information System (INIS)

    Wu Shengxing; Chen Xudong; Zhou Jikai

    2012-01-01

    Highlights: ► Tensile strength of concrete increases with increase in strain rate. ► Strain rate sensitivity of tensile strength of concrete depends on test method. ► High stressed volume method can correlate results from various test methods. - Abstract: This paper presents a comparative experiment and analysis of three different methods (direct tension, splitting tension and four-point loading flexural tests) for determination of the tensile strength of concrete under low and intermediate strain rates. In addition, the objective of this investigation is to analyze the suitability of the high stressed volume approach and Weibull effective volume method to the correlation of the results of different tensile tests of concrete. The test results show that the strain rate sensitivity of tensile strength depends on the type of test, splitting tensile strength of concrete is more sensitive to an increase in the strain rate than flexural and direct tensile strength. The high stressed volume method could be used to obtain a tensile strength value of concrete, free from the influence of the characteristics of tests and specimens. However, the Weibull effective volume method is an inadequate method for describing failure of concrete specimens determined by different testing methods.

  19. Methods and devices for small specimen testing at the Japan Atomic Energy Research Institute

    International Nuclear Information System (INIS)

    Jitsukawa, Shiro; Kizaki, Minoru; Umino, Akira; Shiba, Kiyoyuki; Hishinuma, Akimichi

    1993-01-01

    Devices for a punch test on annular notched specimens, small punch (SP) tests, and miniaturized tension tests in hot cells were developed. A micro-manipulator to handle small specimens and an electro-discharge machine (EDM) to extract miniaturized tension specimens and annular notched specimens from transmission electron microscopy (TEM) disks were also fabricated. These devices were designed and made for remote operation in hot cells. Preliminary tests to evaluate the applicability of test methods were carried out. Correlation between SP test results and tensile properties was not strong. Miniaturized tensile results were reasonably similar to the results with larger specimens. The ductile-brittle transition temperature (DBTT) by the punch test on annular notched specimens was higher than that obtained from the SP test. However, materials dependence of the DBTT was different from that measured by standard Charpy V-notch (CVN) tests. This may be due to a specimen size effect

  20. Standard test method for splitting tensile strength for brittle nuclear waste forms

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    1989-01-01

    1.1 This test method is used to measure the static splitting tensile strength of cylindrical specimens of brittle nuclear waste forms. It provides splitting tensile-strength data that can be used to compare the strength of waste forms when tests are done on one size of specimen. 1.2 The test method is applicable to glass, ceramic, and concrete waste forms that are sufficiently homogeneous (Note 1) but not to coated-particle, metal-matrix, bituminous, or plastic waste forms, or concretes with large-scale heterogeneities. Cementitious waste forms with heterogeneities >1 to 2 mm and 5 mm can be tested using this procedure provided the specimen size is increased from the reference size of 12.7 mm diameter by 6 mm length, to 51 mm diameter by 100 mm length, as recommended in Test Method C 496 and Practice C 192. Note 1—Generally, the specimen structural or microstructural heterogeneities must be less than about one-tenth the diameter of the specimen. 1.3 This test method can be used as a quality control chec...

  1. Dynamic tensile stress–strain characteristics of carbon/epoxy laminated composites in through-thickness direction

    Directory of Open Access Journals (Sweden)

    Nakai Kenji

    2015-01-01

    Full Text Available The effect of strain rate up to approximately ε̇ = 102/s on the tensile stress–strain properties of unidirectional and cross-ply carbon/epoxy laminated composites in the through-thickness direction is investigated. Waisted cylindrical specimens machined out of the laminated composites in the through-thickness direction are used in both static and dynamic tests. The dynamic tensile stress–strain curves up to fracture are determined using the split Hopkinson bar (SHB. The low and intermediate strain-rate tensile stress–strain relations up to fracture are measured on an Instron 5500R testing machine. It is demonstrated that the ultimate tensile strength and absorbed energy up to fracture increase significantly, while the fracture strain decreases slightly with increasing strain rate. Macro- and micro-scopic examinations reveal a marked difference in the fracture surfaces between the static and dynamic tension specimens.

  2. Tensile Bond Strength of Metal Bracket Bonding to Glazed Ceramic Surfaces With Different Surface Conditionings

    Directory of Open Access Journals (Sweden)

    M. Imani

    2011-12-01

    Full Text Available Objective: The objective of this study was to compare the tensile bond strength of metal brackets bonding to glazed ceramic surfaces using three various surface treatments.Materials and Methods: Forty two glazed ceramic disks were assigned to three groups. In the first and second groups the specimens were etched with 9.5% hydrofluoric acid (HFA. Subsequently in first group, ceramic primer and adhesive were applied, but in second group a bonding agent alone was used. In third group, specimens were treated with 35% phosphoric acid followed by ceramic primerand adhesive application. Brackets were bonded with light cure composites. The specimens were stored in distilled water in the room temperature for 24 hours and thermocycled 500 times between 5°C and 55°C. The universal testing machine was used to test the tensile bond strength and the adhesive remenant index scores between three groups was evaluated. The data were subjected to one-way ANOVA, Tukey and Kruskal-Wallis tests respectively.Results: The tensile bond strength was 3.69±0.52 MPa forfirst group, 2.69±0.91 MPa for second group and 3.60±0.41 MPa for third group. Group II specimens showed tensile strength values significantly different from other groups (P<0.01.Conclusion: In spite of limitations in laboratory studies it may be concluded that in application of Scotch bond multipurpose plus adhesive, phosphoric acid can be used instead of HFA for bonding brackets to the glazed ceramic restorations with enough tensile bond strength.

  3. Tensile properties of a titanium modified austenitic stainless steel and the weld joints after neutron irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Shiba, K.; Ioka, I.; Jitsukawa, S.; Hamada, A.; Hishinuma, A. [and others

    1996-10-01

    Tensile specimens of a titanium modified austenitic stainless steel and its weldments fabricated with Tungsten Inert Gas (TIG) and Electron Beam (EB) welding techniques were irradiated to a peak dose of 19 dpa and a peak helium level of 250 appm in the temperature range between 200 and 400{degrees}C in spectrally tailored capsules in the Oak Ridge Research Reactor (ORR) and the High Flux Isotope Reactor (HFIR). The He/dpa ratio of about 13 appm/dpa is similar to the typical helium/dpa ratio of a fusion reactor environment. The tensile tests were carried out at the irradiation temperature in vacuum. The irradiation caused an increase in yield stress to levels between 670 and 800 MPa depending on the irradiation temperature. Total elongation was reduced to less than 10%, however the specimens failed in a ductile manner. The results were compared with those of the specimens irradiated using irradiation capsules producing larger amount of He. Although the He/dpa ratio affected the microstructural change, the impact on the post irradiation tensile behavior was rather small for not only base metal specimens but also for the weld joint and the weld metal specimens.

  4. Effects of hydrogen on the tensile strength characteristics of stainless steels

    International Nuclear Information System (INIS)

    Blanchard, R.; Pelissier, J.; Pluchery, M.; Commissariat a l'Energie Atomique, Saclay

    1961-01-01

    This paper deals with the effects of hydrogen on stainless steel, that might possibly be used as a canning material in hydrogen-cooled reactors. Apparent ultimate-tensile strength is only 80 per cent of initial value for hydrogen content about 50 cc NTP/ 100 g, and reduction in area decreases from 80 to 55 per cent. A special two-stage replica technique has been developed which allows fracture surface of small tensile specimens (about 0.1 mm diam.) to be examined in an electron microscope. All the specimens showed evidence of ductile character throughout the range of hydrogen contents investigated, but the aspect of the fracture surfaces gradually changes with increasing amounts. (author) [fr

  5. Fracture resistance of welded panel specimen with perpendicular crack in tensile

    International Nuclear Information System (INIS)

    Gochev, Todor; Adziev, Todor

    1998-01-01

    Defects caused by natural crack in welded joints of high-strength low-alloy (HSLA) steels are very often. Perpendicular crack in welded joints and its heat treatment after the welding has also an influence on the fracture resistance. The fracture resistance of welded joints by crack in tense panel specimens was investigated by crack mouse opening displesment (CMOD), the parameter of fracture mechanic. Crack propagation was analysed by using a metallographic analysis of fractured specimens after the test. (Author)

  6. Benjamin Button Effect: Recognizable Rejuvenation.

    Science.gov (United States)

    Waldorf, Heidi A

    2017-06-01

    The "Benjamin Button" effect inspired by the popular motion picture, is used to describe the goal of achieving a clearly younger and more attractive, yet still natural appearance utilizing noninvasive and minimally invasive therapies and procedures. Due to high patient demand for enhancement and rejuvenation of the face and body with minimal downtime, there is an ever-increasing number of companies developing products and devices, variety of indications, and field of practitioners offering them. Each option, including topicals, injectables, and devices, promises near magical results. Despite that, a brief review of online discussions and media resources reveals both patients complaining of inadequate results and celebrities with extreme appearances. For clinical practitioners, it is critical to understand the art, science, and economics of noninvasive rejuvenation in order to properly evaluate potential patients, set appropriate expectations, develop, and provide an effective noninvasive rejuvenation plan to achieve a true "Benjamin Button" effect for patients. J Drugs Dermatol. 2017;16(6 Suppl):s74-76..

  7. An Analysis Of Tensile Test Results to Assess the Innovation Risk for an Additive Manufacturing Technology

    Directory of Open Access Journals (Sweden)

    Adamczak Stanisław

    2015-03-01

    Full Text Available The aim of this study was to assess the innovation risk for an additive manufacturing process. The analysis was based on the results of static tensile tests obtained for specimens made of photocured resin. The assessment involved analyzing the measurement uncertainty by applying the FMEA method. The structure of the causes and effects of the discrepancies was illustrated using the Ishikawa diagram. The risk priority numbers were calculated. The uncertainty of the tensile test measurement was determined for three printing orientations. The results suggest that the material used to fabricate the tensile specimens shows clear anisotropy of the properties in relation to the printing direction.

  8. The tensile strength of mechanical joint prototype of lontar fiber composite

    Science.gov (United States)

    Bale, Jefri; Adoe, Dominggus G. H.; Boimau, Kristomus; Sakera, Thomas

    2018-03-01

    In the present study, an experimental activity has been programmed to investigate the effect of joint prototype configuration on tensile strength of lontar (Borassus Flabellifer) fiber composite. To do so, a series of tests were conducted to establish the tensile strength of different joint prototype configuration specimen of lontar fiber composite. In addition, post observation of macroscope was used to map damage behavior. The analysis of lontar fiber composite is a challenge since the material has limited information than others natural fiber composites materials. The results shown that, under static tensile loading, the tensile strength of 13 MPa produced by single lap joint of lontar fiber composite is highest compare to 11 MPa of tensile strength generated by step lap joint and double lap joint where produced the lowest tensile strength of 6 MPa. It is concluded that the differences of tensile strength depend on the geometric dimensions of the cross-sectional area and stress distribution of each joint prototype configuration.

  9. Experimental procedure for the characterization of cyclic behavior from very thin plate specimens

    International Nuclear Information System (INIS)

    Maury, A.; Moulin, D.

    1983-01-01

    Many investigators, including those involved in the INTERNATIONAL BENCHMARK PROJECT ON SIMPLIFIED METHODS FOR ELEVATED TEMPERATURE DESIGN AND ANALYSIS - PROBLEM II, have tried to reproduce experimentally observed behavior by inelastic calculations. Unfortunately, the material characteristics used in the computer code were established from monotonic tensile tests performed with specimens extracted from the plate product itself (1.45 mm thick) employed to construct the ratchetting specimen. It now appears that the cyclic behavior of the material is much more relevant to the phenomenon observed. Hence the need to make this kind of characterization. Nevertheless, the practical problem is to produce cyclic stresses, i.e. tensile and compressive stresses, with very thin specimens. The main difficulty is to prevent the buckling effect. A new special device set up for this particular purpose is described here. The solution adopted was to create uniformly distributed alternative pure bending stresses in the thin plate specimen. Bending moments were produced by two end-grips fixed to the specimen, and these grips were mounted on a conventional test-machine which was displacement-controlled. To reduce tensile and compressive membrane stresses inside the specimen, the grips had two parallel axles of rotation. The forces produced by the machine and the displacements of a number of points of the specimen were continuously recorded during the test, so that cyclically stabilized, bending moments could be evaluated easily for each curvature variation imposed. The very first cyclic experimental data obtained, at room temperature, for the material of the sodium test specimen, a 316 type stainless steel, are presented. It may be noted that the simple specimens were very easy to prepare and hence inexpensive. (orig.)

  10. Effect of implanted helium on tensile properties and hardness of 9% Cr martensitic stainless steels

    Science.gov (United States)

    Jung, P.; Henry, J.; Chen, J.; Brachet, J.-C.

    2003-05-01

    Hundred micrometer thick specimens of 9% Cr martensitic steels EM10 and T91 were homogeneously implanted with He 4 to concentrations up to 0.5 at.% at temperatures from 150 to 550 °C. The specimens were tensile tested at room temperature and at the respective implantation temperatures. Subsequently the fracture surfaces were analysed by scanning electron microscopy and some of the specimens were examined in an instrumented hardness tester. The implanted helium caused hardening and embrittlement which both increased with increasing helium content and with decreasing implantation temperature. Fracture surfaces showed intergranular brittle appearance with virtually no necking at the highest implantation doses, when implanted below 250 °C. The present tensile results can be scaled to tensile data after irradiation in spallation sources on the basis of helium content but not on displacement damage. An interpretation of this finding by microstructural examination is given in a companion paper [J. Nucl. Mater., these Proceedings].

  11. Fracture Testing with Surface Crack Specimens. [especially the residual tensile strength test

    Science.gov (United States)

    Orange, T. W.

    1974-01-01

    Recommendations are given for the design, preparation, and static fracture testing of surface crack specimens. The recommendations are preceded by background information including discussions of stress intensity factors, crack opening displacements, and fracture toughness values associated with surface crack specimens. Cyclic load and sustained load tests are discussed briefly.

  12. Microscopic Characterization of Tensile and Shear Fracturing in Progressive Failure in Marble

    Science.gov (United States)

    Cheng, Yi; Wong, Louis Ngai Yuen

    2018-01-01

    Compression-induced tensile and shear fractures were reported to be the two fundamental fracture types in rock fracturing tests. This study investigates such tensile and shear fracturing process in marble specimens containing two different flaw configurations. Observations first reveal that the development of a tensile fracture is distinct from shear fracture with respect to their nucleation, propagation, and eventual formation in macroscale. Second, transgranular cracks and grain-scale spallings become increasingly abundant in shear fractures as loading increases, which is almost not observed in tensile fractures. Third, one or some dominant extensional microcracks are commonly observed in the center of tensile fractures, while such development of microcracks is almost absent in shear fractures. Microcracks are generally of a length comparable to grain size and distribute uniformly within the damage zone of the shear fracture. Fourth, the width of densely damaged zone in the shear fracture is nearly 10 times of that in the tensile fracture. Quantitative measurement on microcrack density suggests that (1) microcrack density in tensile and shear fractures display distinct characteristics with increasing loading, (2) transgranular crack density in the shear fracture decreases logarithmically with the distance away from the shear fracture center, and (3) whatever the fracture type, the anisotropy can only be observed for transgranular cracks with a large density, which partially explains why microcrack anisotropy usually tends to be unobvious until approaching peak stress in specimens undergoing brittle failure. Microcracking characteristics observed in this work likely shed light to some phenomena and conclusions generalized in seismological studies.

  13. Effects of strain rate, test temperature and test environment on tensile properties of vandium alloys

    International Nuclear Information System (INIS)

    Gubbi, A.N.; Rowcliffe, A.F.; Eatherly, W.S.; Gibson, L.T.

    1996-01-01

    Tensile testing was carried out on SS-3 tensile specimens punched from 0.762-mm-thick sheets of the large heat of V-4Cr-4Ti and small heats of V-3Cr-3Ti and V-6Cr-6Ti. The tensile specimens were annealed at 1000 degrees for 2 h to obtain a fully recrystallized, fine grain microstructure with a grain size in the range of 10-19 μm. Room temperature tests at strain rates ranging from 10 -3 to 5 x 10 -1 /s were carried out in air; elevated temperature testing up to 700 degrees C was conducted in a vacuum better than 1 x 10 -5 torr ( -3 Pa). To study the effect of atomic hydrogen on ductility, tensile tests were conducted at room temperature in an ultra high vacuum chamber (UHV) with a hydrogen leak system

  14. Unstable propagation behavior of a ductile crack in SUS-304 stainless steel under high compliance tensile loading

    International Nuclear Information System (INIS)

    Tomoda, Yoshio

    1981-01-01

    In relation to the safe maintenance of nuclear power plants, it is necessary to prevent reactor coolant pipings from burst type failure caused by the unstable propagation of defects and cracks, such as stress corrosion cracking and fatigue cracks. In ductile materials, crack propagation is stable in tensile loading under fixed grip condition, when a specimen is controlled to deform in proportion to the increase of tensile load. However, it has been known that the instability of ductile cracks occurs after tensile load reached the maximum, especially under constant loading condition arising in the loading devices with high compliance or low tensile rigidity. In order to confirm the reliability of SUS 304 stainless pipes subjected to SCC, the crack propagation behavior was examined with the specimens having center cracks, using both testing machines with high compliance and low compliance. The instability of ductile cracks and the propagation velocity of unstable cracks were analyzed, and the calculated results were compated with the experimental results. Not only the compliance of testing machines but also the conditions of specimens affected the propagation of cracks. (Kako, I.)

  15. Tensile behavior of nickel-base single-crystal superalloy DD6

    Energy Technology Data Exchange (ETDEWEB)

    Xiong, Xinhong, E-mail: xiongxh@whut.edu.cn [School of Logistics Engineering, Wuhan University of Technology, Wuhan 430063 (China); Quan, Dunmiao; Dai, Pengdan; Wang, Zhiping [School of Logistics Engineering, Wuhan University of Technology, Wuhan 430063 (China); Zhang, Qiaoxin [School of Mechanical and Electronic Engineering, Wuhan University of Technology, Wuhan 430070 (China); Yue, Zhufeng [School of Mechanics Civil Engineering and Architecture, Northwestern Polytechnical University, Xi' an 710072 (China)

    2015-06-11

    Tensile behavior of the nickel-base single-crystal superalloy DD6 was studied from room temperature to 1020 °C. The plate specimens were along [001] orientation parallel to the loading axis in tension. The microstructures on the surface and fracture morphology were investigated after tensile test to rupture by scanning electron microscopy (SEM). The results of the present investigation indicate that the yield strength at 650 °C is superior to that at room temperature, 850 °C and 1020 °C. Low ductility and serrated flow in stress–strain curves were also observed at 650 °C. The microstructures on the surface of the plate specimens and fracture morphology observation indicated that localized slip which resulted in glide plane decohesion caused the low ductility of DD6 alloy.

  16. High Temperature Tensile Properties of Unirradiated and Neutron Irradiated 20 Cr-35 Ni Austenitic Steel

    Energy Technology Data Exchange (ETDEWEB)

    Roy, R B; Solly, B

    1966-12-15

    The tensile properties of an unirradiated and neutron irradiated (at 40 deg C) 20 % Cr, 35 % Ni austenitic steel have been studied at 650 deg C, 750 deg C and 820 deg C. The tensile elongation and mode of fracture (transgranular) of unirradiated specimens tested at room temperature and 650 deg C are almost identical. At 750 deg C and 820 deg C the elongation decreases considerably and a large part of the total elongation is non-uniform. Furthermore, the mode of fracture at these temperatures is intergranular and microscopic evidence suggests that fracture is caused by formation and linkup of grain boundary cavities. YS and UTS decrease monotonically with temperature. Irradiated specimens show a further decrease in ductility and an increase in the tendency to grain boundary cracking. Irradiation has no significant effect on the YS, but the UTS are reduced. The embrittlement of the irradiated specimens is attributed to the presence of He and Li atoms produced during irradiation and the possible mechanisms are discussed. Prolonged annealing of irradiated and unirradiated specimens at 650 deg C appears to have no significant effect on tensile properties.

  17. Tensile properties in zircaloy-II after 590 MeV proton irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Dai, Y. [Paul Scherrer Inst. (PSI), Villigen (Switzerland); Victoria, M. [Ecole Polytechnique Federale, Lausanne (Switzerland)

    1997-09-01

    In order to investigate radiation potential damage effects on the SINQ Zircaloy-rod target, four Zircaloy-II tensile specimens were irradiated at the PIREX facility in 1995 to a proton fluence about 3x10{sup 20} p/cm{sup 2}, which produced a radiation damage of about 1.35 displacements per atom (dpa). Tensile test results show that, although there is some reduction in tensile elongation, substantial ductility still exists after such irradiation dose which corresponds to the peak value obtained in the SINQ target for 23 days operation at 1 mA. (author) 1 fig., 2 refs.

  18. Influence of HIP pressure on tensile properties of a 14Cr ODS ferritic steel

    Energy Technology Data Exchange (ETDEWEB)

    Oksiuta, Z., E-mail: z.oksiuta@pb.edu.pl [Bialystok Technical University, Mechanical Department, Wiejska 45c, 15-351 Bialystok (Poland); Ozieblo, A.; Perkowski, K.; Osuchowski, M. [Institute of Ceramics and Building Materials, Postępu 9, 02-676 Warsaw (Poland); Lewandowska, M. [Warsaw University of Technology, Woloska 141, 02-504 Warsaw (Poland)

    2014-02-15

    Highlights: • The HIPping parameters of the 14Cr–2W–0.3Ti–0.3Y{sub 2}O{sub 3} ODS steel powder were investigated. • The density and microstructure of the tested specimens after HIPping were studied. • The mechanical properties, high temperature tensile tests, were performed. • Residual porosity was observed in all tested specimens. • HIPping pressure has negligible influence on the strength of the ODS steel however improves material ductility. - Abstract: An oxide dispersion strengthened ferritic steel with a nominal composition of Fe–14Cr–2W–0.3Ti–0.3Y{sub 2}O{sub 3} (in wt.%) was consolidated by hot isostatic pressing at 1150 °C under various pressures in the range of 185–300 MPa for 3 h. The microstructure, microhardness and high temperature tensile properties of the steel were investigated. With increasing compaction pressure the density of specimens also increased, however OM and SEM observations revealed residual porosity in all tested specimens and similar ferritic microstructure with bimodal-like grains and numerous of large oxide particles, located at the grain boundaries. Mechanical testing revealed that compaction pressure has negligible influence on the hardness and tensile strength of the ODS steel, however improves the material ductility.

  19. Influence of HIP pressure on tensile properties of a 14Cr ODS ferritic steel

    International Nuclear Information System (INIS)

    Oksiuta, Z.; Ozieblo, A.; Perkowski, K.; Osuchowski, M.; Lewandowska, M.

    2014-01-01

    Highlights: • The HIPping parameters of the 14Cr–2W–0.3Ti–0.3Y 2 O 3 ODS steel powder were investigated. • The density and microstructure of the tested specimens after HIPping were studied. • The mechanical properties, high temperature tensile tests, were performed. • Residual porosity was observed in all tested specimens. • HIPping pressure has negligible influence on the strength of the ODS steel however improves material ductility. - Abstract: An oxide dispersion strengthened ferritic steel with a nominal composition of Fe–14Cr–2W–0.3Ti–0.3Y 2 O 3 (in wt.%) was consolidated by hot isostatic pressing at 1150 °C under various pressures in the range of 185–300 MPa for 3 h. The microstructure, microhardness and high temperature tensile properties of the steel were investigated. With increasing compaction pressure the density of specimens also increased, however OM and SEM observations revealed residual porosity in all tested specimens and similar ferritic microstructure with bimodal-like grains and numerous of large oxide particles, located at the grain boundaries. Mechanical testing revealed that compaction pressure has negligible influence on the hardness and tensile strength of the ODS steel, however improves the material ductility

  20. Effects of Head Size on the Performance of Twist-Off Bolts

    OpenAIRE

    Schnupp, Keith Otto

    2003-01-01

    This study examines a specific application of button-head type twist-off bolts. Currently, the Research Council on Structural Connections Specification (2000) removes the requirement for ASTM F436 washers (ASTM 2000a) under the bolt head of twist-off bolts where the head diameter equals or exceeds that of an ASTM F436 washer when oversized and slotted holes are used. The need for washers is also removed for A490 strength bolts used on steels with specified yield strengths less than 40 ksi p...

  1. Development of Tensile Softening Model for Plain Concrete

    Energy Technology Data Exchange (ETDEWEB)

    Lee, S.K.; Song, Y.C. [Korea Electric Power Research Institute, Taejon (Korea)

    2002-07-01

    Large-scale direct tensile softenng tests using plate concrete specimens(4000, 5000psi) with notch were performed under uniaxial stress. There were presented the basic physical properties and the complete load-CMOD(Crack Mouth Opening Displacement) curves for them And them the fracture energy was evaluated using the complete load-CMOD curves respectively, and there was presents optimal tensile softening model which is modified by a little revision of an existing one. Therefore, here provided the real verification data through the tests for developing other nonlinear concrete finite element models. (author). 32 refs., 38 figs., 4 tabs.

  2. Tensile and fatigue behavior of polymer composites reinforced with superelastic SMA strands

    Science.gov (United States)

    Daghash, Sherif M.; Ozbulut, Osman E.

    2018-06-01

    This study explores the use of superelastic shape memory alloy (SMA) strands, which consist of seven individual small-diameter wires, in an epoxy matrix and characterizes the tensile and fatigue responses of the developed SMA/epoxy composites. Using a vacuum assisted hand lay-up technique, twelve SMA fiber reinforced polymer (FRP) specimens were fabricated. The developed SMA-FRP composites had a fiber volume ratio of 50%. Tensile response of SMA-FRP specimens were characterized under both monotonic loading and increasing amplitude loading and unloading cycles. The degradation in superelastic properties of the developed SMA-FRP composites during fatigue loading at different strain amplitudes was investigated. The effect of loading rate on the fatigue response of SMA-FRP composites was also explored. In addition, fractured specimens were examined using the scanning electron microscopy (SEM) technique to study the failure mechanisms of the tested specimens. A good interfacial bonding between the SMA strands and epoxy matrix was observed. The developed SMA-FRP composites exhibited good superelastic behavior at different strain amplitudes up to at least 800 cycle after which significant degradation occurred.

  3. Tensile Characterization of FRP Rods for Reinforced Concrete Structures

    Science.gov (United States)

    Micelli, F.; Nanni, A.

    2003-07-01

    The application of FRP rods as an internal or external reinforcement in new or damaged concrete structures is based on the development of design equations that take into account the mechanical properties of FRP material systems.The measurement of mechanical characteristics of FRP requires a special anchoring and protocol, since it is well known that these characteristics depend on the direction and content of fibers. In this study, an effective tensile test method is described for the mechanical characterization of FRP rods. Twelve types of glass and carbon FRP specimens with different sizes and surface characteristics were tested to validate the procedure proposed. In all, 79 tensile tests were performed, and the results obtained are discussed in this paper. Recommendations are given for specimen preparation and test setup in order to facilitate the further investigation and standardization of the FRP rods used in civil engineering.

  4. Effect of cold work on tensile behavior of irradiated type 316 stainless steel

    International Nuclear Information System (INIS)

    Klueh, R.L.; Maziasz, P.J.

    1986-01-01

    Tensile specimens were irradiated in ORR at 250, 290, 450, and 500 0 C to produce a displacement damage of approx.5 dpa and 40 at. ppM He. Irradiation at 250 and 290 0 C caused an increase in yield stress and ultimate tensile strength and a decrease in ductility relative to unaged and thermally aged controls. The changes were greatest for the 20%-cold-worked steel and lowest for the 50%-cold-worked steel. Irradiation at 450 0 C caused a slight relative decrease in strength for all cold-worked conditions. A large decrease was observed at 500 0 C, with the largest decrease occurring for the 50%-cold-worked specimen. No bubble, void, or precipitate formation was observed for specimens examined by transmission electron microscopy (TEM). The irradiation hardening was correlated with Frank-loop and ''black-dot'' loop damage. A strength decrease at 500 0 C was correlated with dislocation network recovery. Comparison of tensile and TEM results from ORR-irradiated steel with those from steels irradiated in the High Flux Isotope Reactor and the Experimental Breeder Reactor indicated consistent strength and microstructure changes

  5. Analysis of Deformation and Failure Behaviors of TIG Welded Dissimilar Metal Joints Using Miniature Tensile Specimens

    Energy Technology Data Exchange (ETDEWEB)

    Shin, Ji-Hwan; Jahanzeb, Nabeel; Kim, Min-Seong; Hwang, Ji-Hyun; Choi, Shi-Hoon [Sunchon National University, Suncheon (Korea, Republic of)

    2017-02-15

    The deformation and failure behaviors of dissimilar metal joints between SS400 steel and STS316L steel were investigated. The dissimilar metal joints were fabricated using the tungsten inert gas (TIG) welding process with STS309 steel as a filler metal. The microstructures of the dissimilar metal joints were investigated using an optical microscope and EBSD technique. The mechanical properties of the base metal (BM), heat affected zone (HAZ) and weld metal (WM) were measured using a micro-hardness and micro-tension tester combined with the digital image correlation (DIC) technique. The HAZ of the STS316L steel exhibited the highest micro-hardness value, and yield/tensile strengths, while the BM of the SS440 steel exhibited the lowest micro-hardness value and yield /tensile strengths. The grain size refinement in the HAZ of SS400 steel induced an enhancement of micro-hardness value and yield/tensile strengths compared to the BM of the SS400 steel. The WM, which consists of primary δ-ferrite and a matrix of austenite phase, exhibited relatively a high micro-hardness value, yield /tensile strengths and elongation compared to the BM and HAZ of the SS400 steel.

  6. Effects of strain rate, test temperature and test environment on tensile properties of vandium alloys

    Energy Technology Data Exchange (ETDEWEB)

    Gubbi, A.N.; Rowcliffe, A.F.; Eatherly, W.S.; Gibson, L.T. [Oak Ridge National Lab., TN (United States)

    1996-10-01

    Tensile testing was carried out on SS-3 tensile specimens punched from 0.762-mm-thick sheets of the large heat of V-4Cr-4Ti and small heats of V-3Cr-3Ti and V-6Cr-6Ti. The tensile specimens were annealed at 1000{degrees} for 2 h to obtain a fully recrystallized, fine grain microstructure with a grain size in the range of 10-19 {mu}m. Room temperature tests at strain rates ranging from 10{sup {minus}3} to 5 x 10{sup {minus}1}/s were carried out in air; elevated temperature testing up to 700{degrees}C was conducted in a vacuum better than 1 x 10{sup {minus}5} torr (<10{sup {minus}3} Pa). To study the effect of atomic hydrogen on ductility, tensile tests were conducted at room temperature in an ultra high vacuum chamber (UHV) with a hydrogen leak system.

  7. A Novel Geometry for Shear Test Using Axial Tensile Setup

    Directory of Open Access Journals (Sweden)

    Sibo Yuan

    2018-05-01

    Full Text Available This paper studies a novel geometry for the in-plane shear test performed with an axial electromechanical testing machine. In order to investigate the influence of the triaxiality rate on the mechanical behavior, different tests will be performed on the studied material: simple tensile tests, large tensile tests and shear tests. For the whole campaign, a common equipment should be employed to minimize the impact of the testing device. As a consequence, for the shear tests, the geometry of the specimen must be carefully designed in order to adapt the force value and make it comparable to the one obtained for the tensile tests. Like most of the existing shear-included tensile test specimens, the axial loading is converted to shear loading at a particular region through the effect of geometry. A symmetric shape is generally preferred, since it can restrict the in-plane rotation of the shear section, keep shear increasing in a more monotonic path and double the force level thanks to the two shear zones. Due to the specific experimental conditions, such as dimensions of the furnace and the clamping system, the position of the extensometer or the restriction of sheet thickness (related to the further studies of size effect at mesoscale and hot temperature, several geometries were brought up and evaluated in an iterative procedure via finite element simulations. Both the numerical and experimental results reveal that the final geometry ensures some advantages. For instance, a relatively low triaxiality in the shear zone, limited in-plane rotation and no necking are observed. Moreover, it also prevents any out-of-plane displacement of the specimen which seems to be highly sensitive to the geometry, and presents a very limited influence of the material and the thickness.

  8. Investigation of Tensile Creep of a Normal Strength Overlay Concrete.

    Science.gov (United States)

    Drexel, Martin; Theiner, Yvonne; Hofstetter, Günter

    2018-06-12

    The present contribution deals with the experimental investigation of the time-dependent behavior of a typical overlay concrete subjected to tensile stresses. The latter develop in concrete overlays, which are placed on existing concrete structures as a strengthening measure, due to the shrinkage of the young overlay concrete, which is restrained by the substrate concrete. Since the tensile stresses are reduced by creep, creep in tension is investigated on sealed and unsealed specimens, loaded at different concrete ages. The creep tests as well as the companion shrinkage tests are performed in a climatic chamber at constant temperature and constant relative humidity. Since shrinkage depends on the change of moisture content, the evolution of the mass water content is determined at the center of each specimen by means of an electrolytic resistivity-based system. Together with the experimental results for compressive creep from a previous study, a consistent set of time-dependent material data, determined for the same composition of the concrete mixture and on identical specimens, is now available. It consists of the hygral and mechanical properties, creep and shrinkage strains for both sealed and drying conditions, the respective compliance functions, and the mass water contents in sealed and unsealed, loaded and load-free specimens.

  9. The characteristics of ultra-high performance concrete and cracking behavior of reinforced concrete tensile specimens

    Directory of Open Access Journals (Sweden)

    H.A. Rahdar

    2016-09-01

    Full Text Available The tensile behavior of concrete depends on some factors such as member dimensions, reinforcement ratio, diameter of rebar, strength and elasticity modulus of material. In this research the experimental method is used to examine the characteristics and the behavior of ultra-high performance concrete on the tensile behavior of concrete members reinforced by steel rebar. The results show that increasing the rebar cover on diameter rebar ratio (C/d increases the initial stiffening before the cracking stage in concrete. Also, by increasing of reinforcement ratio the cracking space decreased.

  10. The postirradiation tensile properties and microstructure of several vanadium alloys

    International Nuclear Information System (INIS)

    Braski, D.N.

    1988-01-01

    Tensile specimens of V-15Cr-5Ti, Vanstar-7, V-3Ti-1si, and V-20Ti were irradiated at 420/degrees/C in FFTF-MOTA to a damage level of 82 dpa. Helium was preimplanted to levels up to 480 appm in selected specimens using a modified tritium trick. Irradiation hardening was the dominant effect influencing the postirradiation tensile properties, and it markedly increased the yield strength and reduced the total elogation. The V-15Cr-5Ti alloy was very sensitive to helium embrittlement, but Vanstar-7 and V-3Ti-1Si were only slightly affected. Without helium, negligible swelling (<1%) were measured in V-3Ti-1Si and V-20Ti. Preimplanted helium increased swelling in V-3Ti-1Si by increasing cavity nucleation. 11 refs., 11 figs., 3 tabs

  11. High temperature tensile properties of 316 stainless steel implanted with helium

    International Nuclear Information System (INIS)

    Hasegawa, Akira; Yamamoto, Norikazu; Shiraishi, Haruki

    1993-01-01

    Helium embrittlement is one of the problems in structural materials for fusion reactors. Recently, martensitic steels have been developed which have a good resistance to high-temperature helium embrittlement, but the mechanism has not yet been clarified. In this paper, tensile behaviors of helium implanted austenitic stainless steels, which are sensitive to the helium embrittlement, were studied and compared with those of martensitic steels under the same experimental conditions, and the effect of microstructure on helium embrittlement was discussed. Helium was implanted by 300 appm at 573-623 K to miniature tensile speciments of 316 austenitic steels using a cyclotron accelerator. Solution annealed (316SA) and 20% cold worked (316CW) specimens were used. Post-implantation tensile tests were carried out at 573, 873 and 973 K. Yield stress at 573 K increased with the helium implantation in 316SA and 316CW, but the yield stress changes of 316SA at 873 and 973 K were different from that of 316CW. Black-dots were observed in the as-implanted specimen and bubbles were observed in the speciments tensile-tested at 873 and 973 K. Intergranular fracture was observed at only 973 K in both of the 316SA and 316CW specimens. Therefore, cold work did not suppress the high-temperature helium embrittlement under this experimental condition. The difference in the influence of helium on type 316 steel and 9Cr martensitic steels were discussed. Test temperature change of reduction in are showed clearly that helium embrittlement did not occur in 9Cr martensitic steels but occurred in 316 austenitic steels. Fine microstructures of 9Cr martensitic steels should suppress helium embrittlement at high temperatures. (author)

  12. Gertrude Stein’s Tender Buttons (1911)

    DEFF Research Database (Denmark)

    Balle, Søren Hattesen

    Gertrude Stein’s book of prose poems Tender Buttons has been characterized as a modernist literary work by most of its critics. As a distinctive feature of its modernist poetics critics in particular emphasize Stein’s denial of representation through verbal abstraction and autotelism. This paper......, however, intends to read Tender Buttons somewhat differently by suggesting that the poems may be viewed as an example of a displaced Rabbinic hermeneutics in the sense given the term by Susan Handelman. Inasmuch as Stein refuses to name the many objects properly that the titles of the poems introduce...... and instead – to employ her own term – “abuses” their names by way of wordplay, punning, syntactical ambiguity, and semantic disruption, she impersonates a secular Reb Stein, who stays faithful to the Scripture by sacred contempt of representation and obedience to (the play of) the letter. Perhaps...

  13. An effective uniaxial tensile stress-strain relationship for prestressed concrete

    International Nuclear Information System (INIS)

    Chitnuyanondh, L.; Rizkalla, S.; Murray, D.W.; MacGregor, J.G.

    1979-02-01

    This report evaluates the direct tensile strength and an equivalent uniaxial tensile stress-strain relationship for prestressed concrete using data from specimens tested at the University of Alberta which represent segments from the wall of a containment vessel. The stress-strain relationship, when used in conjunction with the BOSOR5 program, enables prediction of the response of prestressed concrete under any biaxial combination of compressive and/or tensile stresses. Comparisons between the experimental and analytical (BOSOR5) load-strain response of the wall segments are also presented. It is concluded that the BOSOR5 program is able to predict satisfactorily the response of the wall segments and multi-layered shell structures. (author)

  14. Tensile and high cycle fatigue behaviors of high-Mn steels at 298 and 110 K

    Energy Technology Data Exchange (ETDEWEB)

    Seo, Wongyu; Jeong, Daeho; Sung, Hyokyung; Kim, Sangshik, E-mail: sang@gnu.ac.kr

    2017-02-15

    Tensile and high cycle fatigue behaviors of high-Mn austenitic steels, including 25Mn, 25Mn0.2Al, 25Mn0.5Cu, 24Mn4Cr, 22Mn3Cr and 16Mn2Al specimens, were investigated at 298 and 110 K. Depending on the alloying elements, tensile ductility of high-Mn steels either increased or decreased with decreasing temperature from 298 to 110 K. Reasonable correlation between the tendency for martensitic tranformation, the critical twinning stress and the percent change in tensile elongation suggested that tensile deformation of high-Mn steels was strongly influenced by SFE determining TRIP and TWIP effects. Tensile strength was the most important parameter in determining the resistance to high cycle fatigue of high-Mn steels with an exceptional work hardening capability at room and cryogenic temperatures. The fatigue crack nucleation mechanism in high-Mn steels did not vary with decreasing tempertature, except Cr-added specimens with grain boundary cracking at 298 K and slip band cracking at 110 K. The EBSD (electron backscatter diffraction) analyses suggested that the deformation mechanism under fatigue loading was significantly different from tensile deformation which could be affected by TRIP and TWIP effects. - Highlights: •The resistances to HCF of various high-Mn steels were measured. •The variables affecting tensile and HCF behaviors of high-Mn steels were assessed. •The relationship between tensile and the HCF behaviors of high-Mn steels was established.

  15. Experiment study on four button electrode used to monitor position of high current electron-beam

    International Nuclear Information System (INIS)

    Xu Tiezheng; Wang Huacen; Xie Yutong; Zhang Wenwei

    2004-01-01

    The button electrode is one that widely used in high energy accelerators, such as storage ring, and the button electrode has many merit like high accuracy, high resolution, resisting magnetic field, simple machinery, without magnetic core and low cost, etc. It's helpful that the button electrode is used as the beam position monitor in the linear induction accelerator. The experimental facilities have been designed and set up and it can simulate the beam of linear induction accelerator. The button electrode beam position monitor experiment have been done on the experimental facilities. The result of the experiment prove that the button electrode has an accuracy of 0.5 mm, and can reflect the wave of electron-beam accurately

  16. Utilization of ISO 6892:2009 testing standard for determining tensile properties of TM380 mild steel

    CSIR Research Space (South Africa)

    Shoke, L

    2013-04-01

    Full Text Available mild steel. To achieve this objective, we reviewed the ISO 6892:2009 tensile testing standard along with reported good practice guidelines. Tensile tests were conducted on a dog-bone shaped TM380 mild steel specimen with strain gauges attached on either...

  17. The validity of wireless iButtons® and thermistors for human skin temperature measurement

    International Nuclear Information System (INIS)

    Smith, A D Harper; Walsh, N P; Crabtree, D R; Bilzon, J L J

    2010-01-01

    Skin temperature is a fundamental variable in human thermo-physiology, and yet skin temperature measurement remains impractical in most free-living, exercise and clinical settings, using currently available hard-wired methods. The purpose of this study was to compare wireless iButtons® and hard-wired thermistors for human skin temperature measurement. In the first of two investigations, iButtons® and thermistors monitored temperature in a controlled water bath (range: 10–40 °C) and were referenced against a certified, mercury thermometer. In the second investigation, eight healthy males completed three randomized trials (ambient temperature = 10 °C, 20 °C and 30 °C) while both devices recorded skin temperature at rest (in low and high wind velocities) and during cycle-ergometry exercise. The results are as follows; Investigation 1: both devices displayed very high validity correlation with the reference thermometer (r > 0.999). Prior to correction, the mean bias was +0.121 °C for iButtons® and +0.045 °C for thermistors. Upon calibration correction the mean bias for iButtons® and thermistors was not significantly different from zero bias. Interestingly, the typical error of the estimate of iButtons® (0.043 °C) was 1.5 times less than that of thermistors (0.062 °C), demonstrating iButtons'® lower random error. Investigation 2: the offset between iButton® and thermistor readings was generally consistent across conditions; however, thermistor responses gave readings that were always closer to ambient temperature than those given by iButtons®, suggesting potential thermistor drift towards environmental conditions. Mean temperature differences between iButtons® and thermistors during resting trials ranged from 0.261 °C to 1.356 °C. Mean temperature differences between iButtons® and thermistors during exercise were 0.989 °C (ambient temperature = 10 °C), 0.415 °C (ambient temperature = 20 °C) and 0.318 °C (ambient temperature = 30 °C). Observed

  18. Effect of soldering techniques and gap distance on tensile strength of soldered Ni-Cr alloy joint.

    Science.gov (United States)

    Lee, Sang-Yeob; Lee, Jong-Hyuk

    2010-12-01

    The present study was intended to evaluate the effect of soldering techniques with infrared ray and gas torch under different gap distances (0.3 mm and 0.5 mm) on the tensile strength and surface porosity formation in Ni-Cr base metal alloy. Thirty five dumbbell shaped Ni-Cr alloy specimens were prepared and assigned to 5 groups according to the soldering method and the gap distance. For the soldering methods, gas torch (G group) and infrared ray (IR group) were compared and each group was subdivided by corresponding gap distance (0.3 mm: G3 and IR3, 0.5 mm: G5, IR5). Specimens of the experimental groups were sectioned in the middle with a diamond disk and embedded in solder blocks according to the predetermined distance. As a control group, 7 specimens were prepared without sectioning or soldering. After the soldering procedure, a tensile strength test was performed using universal testing machine at a crosshead speed 1 mm/min. The proportions of porosity on the fractured surface were calculated on the images acquired through the scanning electronic microscope. Every specimen of G3, G5, IR3 and IR5 was fractured on the solder joint area. However, there was no significant difference between the test groups (P > .05). There was a negative correlation between porosity formation and tensile strength in all the specimens in the test groups (P tensile strength of joints and porosity formations between the gas-oxygen torch soldering and infrared ray soldering technique or between the gap distance of 0.3 mm and 0.5 mm.

  19. Key Aroma Compounds in Lippia dulcis (Dushi Button).

    Science.gov (United States)

    Schmitt, Rainer; Cappi, Michael; Pollner, Gwendola; Greger, Veronika

    2018-03-14

    An aroma extract dilution analysis (AEDA) applied on aroma extracts prepared from the edible flower Dushi Button ( Lippia dulcis) resulted in the detection of 34 odor-active compounds. The highest flavor dilution (FD) factors were determined for methyl 2-methylbutanoate, ethyl 2-methylbutanoate, 4-mercapto-4-methyl-2-pentanone, an unknown caramel-like compound, and vanillin. Quantitative measurements performed by application of stable isotope dilution assays (SIDA), followed by a calculation of odor activity values (OAVs), resulted in the revelation of 4-mercapto-4-methyl-2-pentanone, linalool, myrcene, ethyl 2-methylbutanoate, methyl 2-methylbutanoate, and ( Z)-3-hexenal as important contributors to the flavor of Dushi Buttons.

  20. Tensile and fracture toughness characteristics of Zr-2.5Nb pressure tube

    International Nuclear Information System (INIS)

    Jung, H. C.; Kim, Y. S.; Ahn, S. B.; Kim, S. S.; Im, K. S.

    2004-01-01

    The object of this study is to evaluate the characteristics of tensile and fracture toughness of Zr-2.5Nb pressure tube. The transverse tensile tests were performed at various temperatures and the fracture toughness tests were carried out at room temperature using the CCT (curved compact tension) specimen. These specimens were directly machined from the pressure tube retaining original curvatures. Also, the fracture toughness of two sets of Zr-2.5Nb manufactured at different time was compared. The chemical analysis and the Vicker's hardness tests were performed at two sets of Zr-2.5Nb pressure tube. The Vicker's hardness value of SET-2 containing more oxygen and carbon relatively was higher about 11 than that of SET-1

  1. Investigation of the tensile properties of continuous steel wire-reinforced gray cast iron composite

    Energy Technology Data Exchange (ETDEWEB)

    Akdemir, Ahmet [Department of Mechanical Engineering, Selcuk University, Konya (Turkey); Kus, Recai [Department of Mechanical Education, Selcuk University, Konya (Turkey); Simsir, Mehmet, E-mail: msimsir@cumhuriyet.edu.tr [Department of Metallurgical and Materials Engineering, Cumhuriyet University, Kayseri Yolu 7. Km, 58140 Sivas (Turkey)

    2011-04-25

    Research highlights: {yields} Metal matrix composite (MMC) is an important structural material. {yields} Gray cast irons as a matrix material in MMC have more advantages than other cast irons. {yields} Interface greatly determines the mechanical properties of MMC. {yields} Interface formed by diffusion of carbon atoms. {yields} While decarburizing takes place in gray cast iron, carburiszing takes place in steel near the interface. - Abstract: The aim of the present study was to improve the tensile properties of gray cast iron by reinforcing the material with a steel wire. The composite was produced by sand mold casting, and the specimens were normalized by applying heat treatments at 800 deg. C, 850 deg. C, and 900 deg. C. Tension tests were conducted on gray cast iron and composite specimens, and the microstructure of the specimens was examined with an optical microscope. The fracture surface of the tension test specimens was examined with a scanning electron microscope (SEM), and graphite-free transition regions with high degrees of hardness were observed due to the diffusion of carbon from the cast iron to the steel wire. The microstructure of the transition region (fine pearlitic phase with partially dissolved graphite flakes) and the bond quality in the transition region increased the tensile properties of cast iron composites. Also, it is concluded that the tensile properties of gray cast iron increased with an increase in the normalization temperature.

  2. Investigation of the tensile properties of continuous steel wire-reinforced gray cast iron composite

    International Nuclear Information System (INIS)

    Akdemir, Ahmet; Kus, Recai; Simsir, Mehmet

    2011-01-01

    Research highlights: → Metal matrix composite (MMC) is an important structural material. → Gray cast irons as a matrix material in MMC have more advantages than other cast irons. → Interface greatly determines the mechanical properties of MMC. → Interface formed by diffusion of carbon atoms. → While decarburizing takes place in gray cast iron, carburiszing takes place in steel near the interface. - Abstract: The aim of the present study was to improve the tensile properties of gray cast iron by reinforcing the material with a steel wire. The composite was produced by sand mold casting, and the specimens were normalized by applying heat treatments at 800 deg. C, 850 deg. C, and 900 deg. C. Tension tests were conducted on gray cast iron and composite specimens, and the microstructure of the specimens was examined with an optical microscope. The fracture surface of the tension test specimens was examined with a scanning electron microscope (SEM), and graphite-free transition regions with high degrees of hardness were observed due to the diffusion of carbon from the cast iron to the steel wire. The microstructure of the transition region (fine pearlitic phase with partially dissolved graphite flakes) and the bond quality in the transition region increased the tensile properties of cast iron composites. Also, it is concluded that the tensile properties of gray cast iron increased with an increase in the normalization temperature.

  3. [Button gastrostomy in children].

    Science.gov (United States)

    Kozlov, Iu A; Novozhilov, V A; Rasputin, A A; Us, G P; Kuznetsova, N N

    2015-01-01

    For the period January 2002 to December 2013 it was performed 84 interventions for introduction of gastrostomy tube. The first group included 24 open operations and the second group had 60 laparoscopic operations by using of button devices MIC-KEY (Kimberly-Clark, Roswell, USA) in neonates and infants. Statistically significant difference was not observed during comparison of demographic data of patients. Differences in groups were found in statistical analysis of intra- and postoperative parameters (p<0.05). Mean duration of surgery in the first group was 37.29 min, in the second group - 23.97 min. Time to start of feeding and transition to complete enteral nutrition was less in patients who underwent laparoscopic surgery than after open intervention (10.5 and 19.13 hours, 23.79 and 35.88 hours respectively; p<0.05). It was revealed augmentation of hospital stay in the 1st group in comparison with the 2(nd) group (11.71 and 7.09 days respectively; p<0.05). Frequency of postoperative complications was 18.33% in the 2(nd) group and 24% - in the 1st group (p<0.05). The authors consider that button devices are simply and effective technique of gastrostomy establishment in children. It is associated with minimal surgery duration and allows to start early enteral nutrition in comparison with open techniques.

  4. Temperature dependency of tensile properties of GFRP composite for wind turbine blades

    Energy Technology Data Exchange (ETDEWEB)

    Huh, Yong Hak; Kim, Jong Il; Kim, Dong Jin; Lee, Gun Chang [Korea Research Institute of Standards and Science, Daejeon (Korea, Republic of)

    2012-09-15

    In this study, the temperature dependency of the tensile properties of a glass fiber reinforced plastic (GFRP) used in wind turbine blades was examined. The tensile strength, elastic modulus, and Poisson's ratio of the tensile specimen manufactured from uniaxial (0 .deg.) and triaxial (0/{+-}45.deg) laminate composite plates were measured at four different testing temperatures-room temperature, -30 .deg. C, -50 .deg. C, and 60 .deg. C. It was found that the tensile strengths and elastic moduli of the uniaxial laminates were greater than those of the triaxial laminates over the testing temperature range. The tensile strength of the two laminates was significantly dependent on the testing temperature, while the dependency of the elastic modulus on the temperature was insignificant. Furthermore, it could be considered that the Poisson's ratio changed slightly with a change in the testing temperature.

  5. Temperature dependency of tensile properties of GFRP composite for wind turbine blades

    International Nuclear Information System (INIS)

    Huh, Yong Hak; Kim, Jong Il; Kim, Dong Jin; Lee, Gun Chang

    2012-01-01

    In this study, the temperature dependency of the tensile properties of a glass fiber reinforced plastic (GFRP) used in wind turbine blades was examined. The tensile strength, elastic modulus, and Poisson's ratio of the tensile specimen manufactured from uniaxial (0 .deg.) and triaxial (0/±45.deg) laminate composite plates were measured at four different testing temperatures-room temperature, -30 .deg. C, -50 .deg. C, and 60 .deg. C. It was found that the tensile strengths and elastic moduli of the uniaxial laminates were greater than those of the triaxial laminates over the testing temperature range. The tensile strength of the two laminates was significantly dependent on the testing temperature, while the dependency of the elastic modulus on the temperature was insignificant. Furthermore, it could be considered that the Poisson's ratio changed slightly with a change in the testing temperature

  6. Fracture behavior of nuclear graphites under tensile impact loading

    International Nuclear Information System (INIS)

    Ugachi, Hirokazu; Ishiyama, Shintaro; Eto, Motokuni

    1994-01-01

    Impact tensile strength test was performed with two kinds of HTTR graphites, fine grained isotropic graphite, IG-11 and coarse grained near isotropic graphite, PGX and deformation and fracture behavior under the strain rate of over 100s -1 was measured and the following results were derived: (1) Tensile strength for IG-11 graphite does not depend on the strain rate less than 1 s -1 , but over 1 s -1 , tensile strength for IG-11 graphite increase larger than that measured under 1 s -1 . At the strain rate more than 100 s -1 , remarkable decrease of tensile strength for IG-11 graphite was found. Tensile strength of PGX graphite does not depend on the strain rate less than 1 s -1 , but beyond this value, the sharp tensile strength decrease occurs. (2) Under 100 s -1 , fracture strain for both graphites increase with increase of strain rate and over 100 s -1 , drastic increase of fracture strain for IG-11 graphite was found. (3) At the part of gage length, volume of specimen increase with increase of tensile loading level and strain rate. (4) Poisson's ratio for both graphites decrease with increase of tensile loading level and strain rate. (5) Remarkable change of stress-strain curve for both graphites under 100 s -1 was not found, but over 100 s -1 , the slope of these curve for IG-11 graphite decrease drastically. (author)

  7. Button battery intake as foreign body in Chinese children: review of case reports and the literature.

    Science.gov (United States)

    Liao, Wenjing; Wen, Guangyi; Zhang, Xiaowen

    2015-06-01

    Button batteries have been recognized as one of the dangerous foreign bodies to children for more than 30 years, but few related studies have been published to give more concern in China. We reported 6 cases of button battery intake as foreign body in children. The Chinese literature on button battery as foreign body in children was reviewed. The interval between the accidental ingestion and battery removal ranged from 6 hours to 3 days. Two patients had no sequela, 3 patients had tracheoesophageal fistulas, and 1 patient had nasal septal perforation. Twenty-eight articles about button battery as foreign body in children were obtained by Chinese-language literature searches including 25 case reports, 2 health education articles, and 1 imaging article. In total, 172 cases of button battery intake as foreign body in children were identified, 23 and 10 of the 159 cases involving nasal button battery lodgment developed nasal septal perforation and nasal adhesion, respectively. Tracheoesophageal fistula was identified in 4 of the 12 ingestion cases. One case of button battery intake was in external auditory canal. A small number of children with button battery as foreign body were reported in China, which is 1 of the biggest countries with large population of children.

  8. Dynamic tensile behavior of two-dimensional carbon fiber reinforced silicon carbide matrix composites

    International Nuclear Information System (INIS)

    Chen Xuan; Li Yulong

    2011-01-01

    Graphical abstract: The dynamic tensile behavior of 2D C/SiC composites was experimentally investigated by means of SHTB. Both the fracture surface and bundle fracture surfaces of composites were observed. The strain rate sensitivity of in-bundle interface was concluded as the dominant contributor to the strain rate sensitivity of the tensile strength. Highlights: → The tensile strength increases with strain rate. → The tensile failure strain remains independent of strain rate. → Macro-structural morphology reveals rough fracture surface under dynamic loading. → SEM morphology reveals integrated bundle pull-out under dynamic loading. → Strain rate sensitivity of in-bundle interface leads to that of the tensile strength. - Abstract: An investigation has been undertaken to determine the dynamic and quasi-static tensile behavior of two-dimensional carbon fiber reinforced silicon carbide matrix (2D-C/SiC) composites by means of the split Hopkinson tension bar and an electronic universal test machine respectively. The results indicate that the tensile strength of 2D C/SiC composites is increased at high strain rate. Furthermore, coated specimens show not only a 15% improvement in tensile strength but heightened strain rate sensitivity compared with uncoated ones. It is also shown that the tensile failure strain is strain rate insensitive and remains around 0.4%. Optical macrograph of failed specimens under dynamic loading revealed jagged fracture surfaces characterized by delamination and crack deviation, together with obvious fiber pull-out/splitting, in contrast with the smooth fracture surfaces under quasi-static loading. Scanning electron microscopy micrograph of fracture surface under dynamic loading clearly displayed integrated bundle pull-out which implies suppressed in-bundle debonding and enhanced in-bundle interfacial strengthening, in contrast with extensive in-bundle debonding under quasi-static loading. Thus we conclude that, with 2D C

  9. Biaxial Testing of 2195 Aluminum Lithium Alloy Using Cruciform Specimens

    Science.gov (United States)

    Johnston, W. M.; Pollock, W. D.; Dawicke, D. S.; Wagner, John A. (Technical Monitor)

    2002-01-01

    A cruciform biaxial test specimen was used to test the effect of biaxial load on the yield of aluminum-lithium alloy 2195. Fifteen cruciform specimens were tested from 2 thicknesses of 2195-T8 plate, 0.45 in. and 1.75 in. These results were compared to the results from uniaxial tensile tests of the same alloy, and cruciform biaxial tests of aluminum alloy 2219-T87.

  10. Failure analysis based on microvoid growth for sheet metal during uniaxial and biaxial tensile tests

    International Nuclear Information System (INIS)

    Abbassi, Fethi; Mistou, Sebastien; Zghal, Ali

    2013-01-01

    Highlights: ► Cruciform specimen designed and biaxial tensile test carried out. ► Stereo Correlation Image technique is used for 3D full-filed measurements. ► SEM fractography analysis is used to explain the fracture mechanism. ► Constitutive modeling of the necking phenomenon was developed using GTN model. - Abstract: The aim of the presented investigations is to perform an analysis of fracture and instability during simple and complex load testing by addressing the influence of ductile damage evolution in necking processes. In this context, an improved experimental methodology was developed and successfully used to evaluate localization of deformation during uniaxial and biaxial tensile tests. The biaxial tensile tests are carried out using cruciform specimen loaded using a biaxial testing machine. In this experimental investigation, Stereo-Image Correlation technique has is used to produce the heterogeneous deformations map within the specimen surface. Scanning electron microscope is used to evaluate the fracture mechanism and the micro-voids growth. A finite element model of uniaxial and biaxial tensile tests are developed, where a ductile damage model Gurson–Tvergaard–Needleman (GTN) is used to describe material deformation involving damage evolution. Comparison between the experimental and the simulation results show the accuracy of the finite element model to predict the instability phenomenon. The advanced measurement techniques contribute to understand better the ductile fracture mechanism

  11. Void nucleation in spheroidized steels during tensile deformation

    International Nuclear Information System (INIS)

    Fisher, J.R. Jr.

    1980-04-01

    An investigation was conducted to determine the effects of various mechanical and material parameters on void formation at cementite particles in axisymmetric tensile specimens of spheroidized plain carbon steels. Desired microstructures for each of three steel types were obtained. Observations of void morphology with respect to various microstructural features were made using optical and scanning electron microscopy

  12. Microscopic observation and statics consideration of tensile fracture of TiC coating on stainless steel

    International Nuclear Information System (INIS)

    Okawa, Akira; Hasiguti, Ryukiti

    1986-01-01

    We have measured the tensile fracture properties of the TiC coated SUS316L stainless steel, applying a stress perpendicular to the plane of interface between the coating and the substrate. The fracture of the as grown or non-annealed specimens occurred partially within the TiC layer. A tensile fracture of the TiC coated specimens after vacuum annealing at about 1373 K (1100 deg C) presented arc-shape curved fracture surfaces which can be understood by statics consideration taking into account the maximum stress plane theory and the residual thermal stress. The strengths of non-annealed and annealed specimens are 34.4 MPa (350 kgf/cm 2 ) and 30.2 MPa (308 kgf/cm 2 ), respectively, expressed in terms of Weibull's 50 % fracture stresses. (author)

  13. Surface orientation effects on bending properties of surgical mesh are independent of tensile properties.

    Science.gov (United States)

    Simon, David D; Andrews, Sharon M; Robinson-Zeigler, Rebecca; Valdes, Thelma; Woods, Terry O

    2018-02-01

    Current mechanical testing of surgical mesh focuses primarily on tensile properties even though implanted devices are not subjected to pure tensile loads. Our objective was to determine the flexural (bending) properties of surgical mesh and determine if they correlate with mesh tensile properties. The flexural rigidity values of 11 different surgical mesh designs were determined along three textile directions (machine, cross-machine, and 45° to machine; n = 5 for each) using ASTM D1388-14 while tracking surface orientation. Tensile testing was also performed on the same specimens using ASTM D882-12. Linear regressions were performed to compare mesh flexural rigidity to mesh thickness, areal mass density, filament diameter, ultimate tensile strength, and maximum extension. Of 33 mesh specimen groups, 30 had significant differences in flexural rigidity values when comparing surface orientations (top and bottom). Flexural rigidity and mesh tensile properties also varied with textile direction (machine and cross-machine). There was no strong correlation between the flexural and tensile properties, with mesh thickness having the best overall correlation with flexural rigidity. Currently, surface orientation is not indicated on marketed surgical mesh, and a single mesh may behave differently depending on the direction of loading. The lack of correlation between flexural stiffness and tensile properties indicates the need to examine mesh bending stiffness to provide a more comprehensive understanding of surgical mesh mechanical behaviors. Further investigation is needed to determine if these flexural properties result in the surgical mesh behaving mechanically different depending on implantation direction. © 2017 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 106B: 854-862, 2018. © 2017 Wiley Periodicals, Inc.

  14. A study of the tensile behaviour of flax tows and their potential for composite processing

    International Nuclear Information System (INIS)

    Moothoo, J.; Allaoui, S.; Ouagne, P.; Soulat, D.

    2014-01-01

    Highlights: • Flax tows are characterised by tensile testing under various conditions. • The tensile properties and their dispersion are dependent on the gauge length. • The distribution of the fibres length in specimens commands the tensile behaviour. • Packs of fibre bundle debonding failure mode are observed by image correlation. • Interesting tensile properties are obtained on epoxy impregnated and cured tows. - Abstract: To study the potential of flax tows in composite processing as an alternative to flax spun yarns, a flat flax tow consisting of aligned fibre bundles held together by a natural binder was used and characterised in tension under various conditions. The effect of the gauge length was studied on the dry reinforcement. The experimental results showed that the mechanical properties and failure mechanism varied significantly depending on the gauge length and are discussed in relation to the distribution of elementary fibres within the tow. A characteristic length as from which the mechanical properties are stable has been identified. At this length, the effect of the strain rate on the tensile properties was measured and their sensitivity to the strain rate suggests a viscous effect in the behaviour of the flax tow. To approach process conditions such as wet filament winding, a batch of specimens was impregnated with epoxy prior to tensile testing. The tensile properties under wet conditions were found to be close to the properties under dry conditions and shows that the tow can withstand typical processing tensions. Finally, tensile tests on cured-impregnated tows showed interesting mechanical properties for composite application

  15. Postirradiation tensile properties of Mo and Mo alloys irradiated with 600 MeV protons

    International Nuclear Information System (INIS)

    Mueller, G.V.; Gavillet, D.; Victoria, M.; Martin, J.L.

    1994-01-01

    Tensile specimens of pure Mo and Mo-5 Re, Mo-41 Re and TZM alloys have been irradiated with 600 MeV protons in the PIREX facility at 300 and 660 K to 0.5 dpa. Results of the postirradiation tensile testing show a strong radiation hardening and a severe loss of ductility for all the materials tested at room temperature. ((orig.))

  16. Button battery ingestion: A therapeutic dilemma and clinical issues in management

    Directory of Open Access Journals (Sweden)

    Jashanjot Singh Bhangu

    2016-01-01

    Full Text Available Button batteries, also known as disc batteries, are tiny, round batteries commonly present in numerous household electronic gadgets such as watches, calculators, cameras, hearing aids, penlights, remote control devices, and certain toys. Because of their easy accessibility to children, they pose a serious menace of accidental ingestion or inhalation. Most of the ingestions are benign. However, large-sized button batteries when ingested can become impacted in the esophagus or elsewhere in the gastrointestinal tract with life-threatening repercussions. We report a 4-year-old female child brought to our setup by her parents with an alleged history of ingestion of a button battery of the watch approximately about 2 h back. The child, apart from being anxious, was asymptomatic. An initial radiograph of the chest and abdomen was taken, which showed the battery at the distal end of the stomach. Considering the small size of the battery cell and after seeking the gastroenterologist′s consultation, it was decided that the child would be managed conservatively with oral antacids and serial abdomen skiagrams were obtained. The button battery was eventually detected in the stools after 2 days.

  17. A curved beam test specimen for determining the interlaminar tensile strength of a laminated composite

    Science.gov (United States)

    Hiel, Clement C.; Sumich, Mark; Chappell, David P.

    1991-01-01

    A curved beam type of test specimen is evaluated for use in determining the through-the-thickness strength of laminated composites. Two variations of a curved beam specimen configuration (semicircular and elliptical) were tested to failure using static and fatigue loads. The static failure load for the semicircular specimens was found to be highly sensitive to flaw content, with the specimens falling into two distinct groups. This result supports the use of proof testing for structural validation. Static design allowables are derived based on the Weibull distribution. Fatigue data indicates no measured increase in specimen compliance prior to final fracture. All static and fatigue failures at room temperature dry conditions occurred catastrophically. The elliptical specimens demonstrated unusually high failure strengths indicating the presence of phenomena requiring further study. Results are also included for specimens exposed to a wet environment showing a matrix strength degradation due to moisture content. Further testing is underway to evaluate a fatigue methodology for matrix dominated failures based on residual static strength (wearout).

  18. The effect of temperature on compressive and tensile strengths of commonly used luting cements: an in vitro study.

    Science.gov (United States)

    Patil, Suneel G; Sajjan, Mc Suresh; Patil, Rekha

    2015-02-01

    The luting cements must withstand masticatory and parafunctional stresses in the warm and wet oral environment. Mouth temperature and the temperature of the ingested foods may induce thermal variation and plastic deformation within the cements and might affect the strength properties. The objectives of this study were to evaluate the effect of temperature on the compressive and diametral tensile strengths of two polycarboxylate, a conventional glass ionomer and a resin modified glass ionomer luting cements and, to compare the compressive strength and the diametral tensile strength of the selected luting cements at varying temperatures. In this study, standardized specimens were prepared. The temperature of the specimens was regulated prior to testing them using a universal testing machine at a crosshead speed of 1 mm/min. Six specimens each were tested at 23°C, 37°C and 50°C for both the compressive and diametral tensile strengths, for all the luting cements. All the luting cements showed a marginal reduction in their compressive and diametral tensile strengths at raised temperatures. Fuji Plus was strongest in compression, followed by Fuji I > Poly F > Liv Carbo. Fuji Plus had the highest diametral tensile strength values, followed by Poly F = Fuji I = Liv Carbo, at all temperatures. An increase in the temperature caused no significant reduction in the compressive and diametral tensile strengths of the cements evaluated. The compressive strength of the luting cements differed significantly from one another at all temperatures. The diametral tensile strength of resin modified glass ionomers differed considerably from the other cements, whereas there was no significant difference between the other cements, at all the temperatures.

  19. Small specimen technique for assessing mechanical properties of metallic components

    Energy Technology Data Exchange (ETDEWEB)

    Lobo, Raquel M.; Andrade, Arnaldo H.P.; Morcelli, Aparecido E., E-mail: rmlobo@ipen.br, E-mail: morcelliae@gmail.com [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)

    2017-11-01

    Small Punch Test (SPT) is one of the most promising techniques of small specimen test, which was originally applied in testing of irradiated materials in nuclear engineering. Then it was introduced to other fields as an almost nondestructive method to measure the local mechanical properties that are difficult to be obtained using conventional mechanical tests. Most studies to date are focused on metallic materials, although SPT applications are recently spreading to other materials. The small punch test (SPT) employs small-sized specimens (for example, samples measuring 8 mm in diameter and 0.5 mm thick). The specimen is firmly clamped between two circular dies and is bi-axially strained until failure into a circular hole using a hemispherical punch. The 'load-punch displacement' record can be used to estimate the yield strength, the ultimate tensile strength, the tensile elongation, and the temperature of the ductile-to-brittle transition. Recently, some researchers are working on the use of miniature notched or pre-cracked specimens (denoted as p-SPT) to validate its geometry and dimensions for obtaining the fracture properties of metallic materials. In a first approach, the technique makes it possible to convert primary experimental data into conventional mechanical properties of a massive specimen. In this paper a comprehensive review of the different STP applications is presented with the aim of clarifying its usefulness. (author)

  20. Small specimen technique for assessing mechanical properties of metallic components

    International Nuclear Information System (INIS)

    Lobo, Raquel M.; Andrade, Arnaldo H.P.; Morcelli, Aparecido E.

    2017-01-01

    Small Punch Test (SPT) is one of the most promising techniques of small specimen test, which was originally applied in testing of irradiated materials in nuclear engineering. Then it was introduced to other fields as an almost nondestructive method to measure the local mechanical properties that are difficult to be obtained using conventional mechanical tests. Most studies to date are focused on metallic materials, although SPT applications are recently spreading to other materials. The small punch test (SPT) employs small-sized specimens (for example, samples measuring 8 mm in diameter and 0.5 mm thick). The specimen is firmly clamped between two circular dies and is bi-axially strained until failure into a circular hole using a hemispherical punch. The 'load-punch displacement' record can be used to estimate the yield strength, the ultimate tensile strength, the tensile elongation, and the temperature of the ductile-to-brittle transition. Recently, some researchers are working on the use of miniature notched or pre-cracked specimens (denoted as p-SPT) to validate its geometry and dimensions for obtaining the fracture properties of metallic materials. In a first approach, the technique makes it possible to convert primary experimental data into conventional mechanical properties of a massive specimen. In this paper a comprehensive review of the different STP applications is presented with the aim of clarifying its usefulness. (author)

  1. Comparing Microstructures and Tensile Properties of Intercritically Annealed and Quenched-Tempered 1.7Ni-1.5Cu-0.5Mo-0.2C Powder Metallurgy Steels

    Science.gov (United States)

    Güral, Ahmet; Başak, Hüdayim; Türkan, Mustafa

    2018-01-01

    The aim of this study was to compare the influence of intercritical quenching (IQ), step quenching (SQ) and quenching plus tempering (QT) heat treatments on the microstructure and tensile properties of 1.7Ni-1.5Cu-0.5Mo-0.2C pre-alloyed powder metallurgy (P/M) steels. In the microstructures of the IQ and SQ specimens partial martensite having Ni-rich phases formed up in the soft ferritic matrix. It was observed that unlike Mo, a Cu alloying element dissolved homogeneously in the specimens. The martensite volume fraction (MVF) in the SQ specimens was higher than that in the IQ specimens. It was found that macrohardness, yield and tensile strengths increased, whereas microhardness of ferrite and elongation decreased with increasing MVF. However, with this increase, microhardness values of martensite phases decreased in the IQ specimen, while they increased in SQ specimens. It was observed that the yield, tensile, and elongation values of the QT specimens were lower than those of all intercritically annealed specimens having the same hardness values.

  2. Tensile properties of V-Cr-Ti alloys after exposure in helium and low-partial-pressure oxygen environments

    Energy Technology Data Exchange (ETDEWEB)

    Natesan, K.; Soppet, W.K. [Argonne National Lab., IL (United States)

    1997-04-01

    A test program is in progress to evaluate the effect of oxygen at low pO{sub 2} on the tensile properties of V-(4-5)wt% Cr-(4-5)wt% Ti alloys. Some of the tensile specimens were precharged with oxygen at low pO{sub 2} at 500{degrees}C and reannealed in vacuum at 500{degrees}C in environments with various pO{sub 2} levels and subsequently tensile tested at room temperature. The preliminary results indicate that both approaches are appropriate for evaluating the effect of oxygen uptake on the tensile properties of the alloys. The data showed that in the relatively short-time tests conducted thus far, the maximum engineering stress slightly increased after oxygen exposure but the uniform and total elongation values exhibited significant decrease after exposure in oxygen-containing environments. The data for a specimen exposed to a helium environment were similar to those obtained in low pO{sub 2} environments.

  3. Tensile properties of V-Cr-Ti alloys after exposure in helium and low-partial-pressure oxygen environments

    International Nuclear Information System (INIS)

    Natesan, K.; Soppet, W.K.

    1997-01-01

    A test program is in progress to evaluate the effect of oxygen at low pO 2 on the tensile properties of V-(4-5)wt% Cr-(4-5)wt% Ti alloys. Some of the tensile specimens were precharged with oxygen at low pO 2 at 500 degrees C and reannealed in vacuum at 500 degrees C in environments with various pO 2 levels and subsequently tensile tested at room temperature. The preliminary results indicate that both approaches are appropriate for evaluating the effect of oxygen uptake on the tensile properties of the alloys. The data showed that in the relatively short-time tests conducted thus far, the maximum engineering stress slightly increased after oxygen exposure but the uniform and total elongation values exhibited significant decrease after exposure in oxygen-containing environments. The data for a specimen exposed to a helium environment were similar to those obtained in low pO 2 environments

  4. Possibility of obtaining reliable information on component safety by means of large-scale tensile samples with Orowan-Soete flaws

    International Nuclear Information System (INIS)

    Aurich, D.; Wobst, K.; Kafka, H.

    1984-01-01

    The aim of the paper is to review the present knowledge regarding the ability of wide plate tensile specimen with saw cut trough center flaws of providing accurate information on component reliability; it points out the advantages and disadvantages of this specimen geometries. The effect of temperature, specimen geometry, ligament size and notch radii are discussed in comparison with other specimen geometries. This is followed by a comparison of the results of such tests with tests on inside stressed tanks. Conclusions: wide-plate tensile specimen are generally appropriate for assessing welded joints. However, they result in a more favourable evaluation of low-toughness steels from the point of view of crack growth than of high-toughness and soft steels in case of stresses with incipient cracks, as compared with the results obtained with three-point bending samples. (orig.) [de

  5. 3D modelling of plug failure in resistance spot welded shear-lab specimens (DP600-steel)

    DEFF Research Database (Denmark)

    Nielsen, Kim Lau

    2008-01-01

    are based on uni-axial tensile testing of the basis material, while the modelled tensile response of the shear-lab specimens is compared to experimental results for the case of a ductile failure near the heat affected zone (HAZ). A parametric study for a range of weld diameters is carried out, which makes......Ductile plug failure of resistance spot welded shear-lab specimens is studied by full 3D finite element analysis, using an elastic-viscoplastic constitutive relation that accounts for nucleation and growth of microvoids to coalescence (The Gurson model). Tensile properties and damage parameters...... it possible to numerically relate the weld diameter to the tensile shear force (TSF) and the associated displacement, u (TSF) , respectively. Main focus in the paper is on modelling the localization of plastic flow and the corresponding damage development in the vicinity of the spot weld, near the HAZ...

  6. Assessment of plastic flow and fracture properties with small specimens test techniques for IFMIF-designed specimens

    International Nuclear Information System (INIS)

    Spaetig, P.; Campitelli, E.N.; Bonade, R.; Baluc, N.

    2005-01-01

    The primary mission of the International Fusion Material Irradiation Facility (IFMIF) is to generate a material database to be used for the design of various components, for the licensing and for the assessment of the safe operation of a demonstration fusion reactor. IFMIF is an accelerator-based high-energy neutron source whose irradiation volume is quite limited (0.5 l for the high fluence volume). This requires the use of small specimens to measure the irradiation-induced changes on the physical and mechanical properties of materials. In this paper, we developed finite element models to better analyze the results obtained with two different small specimen test techniques applied to the tempered martensitic steel F82H-mod. First, one model was used to reconstruct the load-deflection curves of small ball punch tests, which are usually used to extract standard tensile parameters. It was shown that a reasonable assessment of the overall plastic flow can be done with small ball punch tests. Second, we investigated the stress field sensitivity at a crack tip to the constitutive behavior, for a crack modeled in plane strain, small-scale yielding and fracture mode I conditions. Based upon a local criterion for cleavage, that appears to be the basis to account for the size and geometry effects on fracture toughness, we showed that the details of the constitutive properties play a key role in modeling the irradiation-induced fracture toughness changes. Consequently, we suggest that much more attention and efforts have to be paid in investigating the post-yield behavior of the irradiated specimens and, in order to reach this goal, we recommend the use of not only tensile specimens but also that of compression ones in the IFMIF irradiation matrices. (author)

  7. Making High-Tensile-Strength Amalgam Components

    Science.gov (United States)

    Grugel, Richard

    2008-01-01

    Structural components made of amalgams can be made to have tensile strengths much greater than previously known to be possible. Amalgams, perhaps best known for their use in dental fillings, have several useful attributes, including room-temperature fabrication, corrosion resistance, dimensional stability, and high compressive strength. However, the range of applications of amalgams has been limited by their very small tensile strengths. Now, it has been discovered that the tensile strength of an amalgam depends critically on the sizes and shapes of the particles from which it is made and, consequently, the tensile strength can be greatly increased through suitable choice of the particles. Heretofore, the powder particles used to make amalgams have been, variously, in the form of micron-sized spheroids or flakes. The tensile reinforcement contributed by the spheroids and flakes is minimal because fracture paths simply go around these particles. However, if spheroids or flakes are replaced by strands having greater lengths, then tensile reinforcement can be increased significantly. The feasibility of this concept was shown in an experiment in which electrical copper wires, serving as demonstration substitutes for copper powder particles, were triturated with gallium by use of a mortar and pestle and the resulting amalgam was compressed into a mold. The tensile strength of the amalgam specimen was then measured and found to be greater than 10(exp 4) psi (greater than about 69 MPa). Much remains to be done to optimize the properties of amalgams for various applications through suitable choice of starting constituents and modification of the trituration and molding processes. The choice of wire size and composition are expected to be especially important. Perusal of phase diagrams of metal mixtures could give insight that would enable choices of solid and liquid metal constituents. Finally, whereas heretofore, only binary alloys have been considered for amalgams

  8. Effect of tensile stress on cavitation damage formation in mercury

    Energy Technology Data Exchange (ETDEWEB)

    Naoe, Takashi, E-mail: naoe.takashi@jaea.go.j [J-PARC Center, Japan Atomic Energy Agency, Tokai-mura, Naka-gun, Ibaraki 319-1195 (Japan); Kogawa, Hiroyuki [J-PARC Center, Japan Atomic Energy Agency, Tokai-mura, Naka-gun, Ibaraki 319-1195 (Japan); Yamaguchi, Yoshihito [Nuclear Safety Research Center, Japan Atomic Energy Agency, Tokai-mura, Naka-gun, Ibaraki 319-1195 (Japan); Futakawa, Masatoshi [J-PARC Center, Japan Atomic Energy Agency, Tokai-mura, Naka-gun, Ibaraki 319-1195 (Japan)

    2010-03-15

    Cavitation erosion or so called pitting damage was investigated under tensile stress conditions in mercury. In MW-class liquid metal spallation targets, pitting damage is a critical issue to satisfy required power and/or lifetime of the target vessel. Cavitation occurs by negative pressure which is induced through pressure wave propagation due to proton beam injection. Pitting damage is formed by microjet and/or shock wave during cavitation bubble collapse. A mercury target vessel suffers tensile stress due to thermal stress or welding. In order to investigate the effect of tensile stress on pitting damage formation, cavitation erosion tests were performed using stress imposed specimens in mercury. An ultrasonic vibratory horn and electro-Magnetic IMpact Testing Machine (MIMTM) were used to vary the cavitation intensity. In the incubation period of pitting damage, damaged area was slightly increased with increasing imposed tensile stress. In the steady state period, a mean depth of erosion was increased by the tensile stress. Additionally, in order to quantitatively evaluate the effect of tensile stress, an indentation test with Vickers indenter was carried out to quasi-statically simulate the impact load. From the measurement of the diagonal length of the indent aspect ratio and hardness, it is recognized that the threshold of the deformation, i.e. pitting damage formation, was decreased by the tensile stress.

  9. Tensile Test of Welding Joint Parts for a Plate-type Fuel Assembly

    Energy Technology Data Exchange (ETDEWEB)

    Yoon, K. H.; Kim, J. Y.; Kim, H. J.; Yim, J. S. [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2013-05-15

    The tensile tests were performed using an INSTRON 4505 (universal tensile) testing machine. These welding joints are composed of two parts for the soundness of the fuel assembly; one is the side plate with a fixing bar and the other is a side plate with an end fitting. These two joint parts are fabricated by TIG welding method. The tensile tests of the welding joints of a plate-type FA are executed by a tensile test. The fixture configurations for the specimen are very important to obtain the strict test results. The maximum strength has an approximately linear correlation with the unit bonding length of the welding joints. In spite of these results, the maximum strengths of the welding joints are satisfied according to the minimum requirement. These tensile tests of the joint parts for a plate-type fuel assembly (FA) have to be executed to evaluate the structural strength. For the tensile test, the joint parts of a FA used in the test are made of aluminum alloy (Al6061-T6)

  10. Tensile Test of Welding Joint Parts for a Plate-type Fuel Assembly

    International Nuclear Information System (INIS)

    Yoon, K. H.; Kim, J. Y.; Kim, H. J.; Yim, J. S.

    2013-01-01

    The tensile tests were performed using an INSTRON 4505 (universal tensile) testing machine. These welding joints are composed of two parts for the soundness of the fuel assembly; one is the side plate with a fixing bar and the other is a side plate with an end fitting. These two joint parts are fabricated by TIG welding method. The tensile tests of the welding joints of a plate-type FA are executed by a tensile test. The fixture configurations for the specimen are very important to obtain the strict test results. The maximum strength has an approximately linear correlation with the unit bonding length of the welding joints. In spite of these results, the maximum strengths of the welding joints are satisfied according to the minimum requirement. These tensile tests of the joint parts for a plate-type fuel assembly (FA) have to be executed to evaluate the structural strength. For the tensile test, the joint parts of a FA used in the test are made of aluminum alloy (Al6061-T6)

  11. Button battery ingestion: the Greek experience and review of the literature.

    Science.gov (United States)

    Amanatidou, Virginia; Sofidiotou, Vassiliki; Fountas, Kostas; Kalostou, Angeliki; Tsamadou, Athina; Papathanassiou, Vassiliki; Neou, Polyxeni

    2011-03-01

    Foreign body ingestion is a common cause of admission in the pediatric emergency room. In the past, button batteries accounted for less than 2% of the foreign bodies ingested by small children, but in the last 2 decades, they show a rapidly increased frequency. The aim of the present study was to evaluate the potential risk after button battery ingestion in relation with the clinical manifestations and to perform a treatment-observation protocol in accordance with the international procedure. In a prospective observational analysis from November 2007 through February 2008, 31 cases of button battery ingestion were recorded by the Greek Poison Information Center. The interval between the accidental ingestion and first medical contact ranged from 5 minutes to 10 days. After initial evaluation including clinical examination and radiological localization of the foreign body, all cases were treated as outpatients. Reported complications included "black stools" in 9% and diarrhea in 3% of cases. In 1 case, the battery was endoscopically removed. The role of primary care physicians in informing the public about the potential danger of button battery digestion is crucial. Pediatricians should educate the parents about this hazard, as part of the routine guidelines for childproofing at home. Once again, prolepsis is the best policy.

  12. An evaluation of the +/-45 deg tensile test for the determination of the in-plane shear strength of composite materials

    Science.gov (United States)

    Kellas, S.; Morton, J.; Jackson, K. E.

    1991-01-01

    The applicability of the +/-45 deg tensile test for the determination of the in-plane shear strength of advanced composite laminates is studied. The assumptions used for the development of the shear strength formulas were examined, and factors such as the specimen geometry and stacking sequence were assessed experimentally. It was found that the strength of symmetric and balanced +/-45 deg laminates depends primarily upon the specimen thickness rather than the specimen width. These findings have important implications for the +/-45 deg tensile test which is recommended by several organizations for the determination of the in-plane shear stress/strain response and the shear strength of continuous fiber reinforced composites. Modifications to the recommended practices for specimen selection and shear strength determination are suggested.

  13. The effect of salivary pH on diametral tensile strength of resin modified glass ionomer cement coated with coating agent

    Science.gov (United States)

    Ismayanti, D.; Triaminingsih, S.; Eriwati, Y. K.

    2017-08-01

    The aim of this study was to evaluate the effect of artificial saliva with different acidities on the diametral tensile strength of Resin Modified Glass Ionomer Cement (RMGIC) coated with varnish and nanofilled coating agent. The specimens coated with coating agents were immersed in artificial saliva with pH of 4.5, 5.5, and 7 for 24 hours in an incubatorat 37°C. The diametral tensile strength of the specimens was tested with Universal Testing Machine. There were no significant differences on the diametral tensile strength of all specimens that were put into groups based on the acidity of the saliva and the type of coating agent (p>0.05). Both varnish and nanofilled coating agent stayed on the RMGIC in the acidic condition that simulated the true condition of oral cavity in people with high caries risk for the 24 hours of maturation.

  14. Hemorrhagic shock secondary to button battery ingestion

    Directory of Open Access Journals (Sweden)

    Naomi Andreia Takesaki

    Full Text Available CONTEXT:Button battery ingestion is a frequent pediatric complaint. The serious complications resulting from accidental ingestion have increased significantly over the last two decades due to easy access to gadgets and electronic toys. Over recent years, the increasing use of lithium batteries of diameter 20 mm has brought new challenges, because these are more detrimental to the mucosa, compared with other types, with high morbidity and mortality. The clinical complaints, which are often nonspecific, may lead to delayed diagnosis, thereby increasing the risk of severe complications.CASE REPORT:A five-year-old boy who had been complaining of abdominal pain for ten days, was brought to the emergency service with a clinical condition of hematemesis that started two hours earlier. On admission, he presented pallor, tachycardia and hypotension. A plain abdominal x-ray produced an image suggestive of a button battery. Digestive endoscopy showed a deep ulcerated lesion in the esophagus without active bleeding. After this procedure, the patient presented profuse hematemesis and severe hypotension, followed by cardiorespiratory arrest, which was reversed. He then underwent emergency exploratory laparotomy and presented a new episode of cardiorespiratory arrest, which he did not survive. The battery was removed through rectal exploration.CONCLUSION:This case describes a fatal evolution of button battery ingestion with late diagnosis and severe associated injury of the digestive mucosa. A high level of clinical suspicion is essential for preventing this evolution. Preventive strategies are required, as well as health education, with warnings to parents, caregivers and healthcare professionals.

  15. Microstructure and tensile properties of tungsten at elevated temperatures

    Energy Technology Data Exchange (ETDEWEB)

    Shen, Tielong [Laboratory for Nuclear Materials, Paul Scherrer Institut, 5232 Villigen PSI (Switzerland); Institute of Modern Physics, Chinese Academy of Sciences, Lanzhou 730000 (China); Dai, Yong, E-mail: yong.dai@psi.ch [Laboratory for Nuclear Materials, Paul Scherrer Institut, 5232 Villigen PSI (Switzerland); Lee, Yongjoong [European Spallation Source, Tunavägen 24, 223 63 Lund (Sweden)

    2016-01-15

    In order to support the development of the 5 MW spallation target for the European Spallation Source, the effect of fabrication process on microstructure, ductile-to-brittle transition temperature (DBTT), tensile and fracture behaviour of powder-metallurgy pure tungsten materials has been investigated. A hot-rolled (HR) tungsten piece of 12 mm thickness and a hot-forged (HF) piece of about 80 mm thickness were used to simulate the thin and thick blocks in the target. The two tungsten pieces were characterized with metallography analysis, hardness measurement and tensile testing. The HR piece exhibits an anisotropic grain structure with an average size of about 330 × 140 × 40 μm in rolling, long transverse and short transverse (thickness) directions. The HF piece possesses a bimodal grain structure with about 310 × 170 × 70 μm grain size in deformed part and about 25 μm sized grains remained from sintering process. Hardness (HV0.2) of the HR piece is slightly greater than that of the HF one. The ductility of the HR tungsten specimens is greater than that of the HF tungsten. For the HF tungsten piece, specimens with small grains in gauge section manifest lower ductility but higher strength. The DBTT evaluated from the tensile results is 250–300 °C for the HR tungsten and about 350 °C for the HF tungsten. - Highlights: • This work was conducted to support the development of the 5 MW spallation target for the European Spallation Source. • The effect of fabrication process on microstructure, ductile-to-brittle transition temperature and tensile behaviour was studied with hot-rolled and hot-forged tungsten. • The tungsten materials were characterized with metallography analysis, hardness measurement and tensile test in a temperature range of 25–500 °C. • The results indicate that the HR tungsten has better mechanical properties in terms of greater ductility and lower ductile-to-brittle transition temperature.

  16. Prediction of tensile curves, at 673 K, of cold-worked and stress-relieved zircaloy-4 from creep data

    International Nuclear Information System (INIS)

    Povolo, F.; Buenos Aires Univ. Nacional; Marzocca, A.J.

    1986-01-01

    A constitutive creep equation, based on jog-drag cell-formation, is used to predict tensile curves from creep data obtained in the same material. The predicted tensile curve are compared with actual stress versus plastic strain data, obtained both in cold-work and stress-relieved specimens. Finally, it is shown that the general features of the tensile curves, at low strain rates, are described by the creep model. (orig.)

  17. Fatal aortoesophageal fistula caused by button batteryingestion in a 1-year-old child

    DEFF Research Database (Denmark)

    Mortensen, Anette; Hansen, Nikolaj Friis; Schiødt, Ole Mikael

    2010-01-01

    Ingestion of a button battery can result in serious complications if the battery becomes lodged in the esophagus. We report a case of a 14-month-old child who died from exsanguination caused by an aortoesophageal fistula caused by a 20-mm lithium button battery lodged in the esophagus...

  18. Fixation of the Achilles tendon insertion using suture button technology.

    Science.gov (United States)

    Fanter, Nathan J; Davis, Edward W; Baker, Champ L

    2012-09-01

    In the operative treatment of Achilles insertional tendinopathy, no guidelines exist concerning which form of fixation of the Achilles tendon insertion is superior. Transcalcaneal drill pin passage does not place any major plantar structures at risk, and the addition of a Krackow stitch and suture button to the fixation technique provides a significant increase in ultimate load to failure in Achilles tendon insertional repairs. Controlled laboratory study. The Achilles tendon insertions in 6 fresh-frozen cadaveric ankles were detached, and transcalcaneal drill pins were passed. Plantar dissection took place to evaluate the drill pin relationship to the plantar fascia, lateral plantar nerve and artery, flexor digitorum longus tendon, and master knot of Henry. The Achilles tendons were then repaired with a double-row suture anchor construct alone or with a suture button and Krackow stitch added to the double-row suture anchor construct. The repairs were then tested to maximum load to failure at 20 mm/min. The mode of failure was recorded, and the mean maximum load to failure was assessed using the Student t test for distributions with equal variance. Transcalcaneal drill pin passage did not place any selected anatomic structures at risk. The mean maximum load to failure for the suture bridge group was 239.2 N; it was 391.4 N for the group with the suture button (P = .014). The lateral plantar artery was the structure placed at greatest risk from drill pin placement, with a mean distance of 22.7 mm (range, 16.5-29.2 mm) between the pin and artery. In this laboratory study, transcalcaneal drill pin passage appeared to be anatomically safe, and the use of suture button technology with a Krackow stitch for Achilles tendon insertional repair significantly increased repair strength. Achilles tendon insertional repair with suture button fixation and a Krackow stitch may facilitate the earlier institution of postoperative rehabilitation and improve clinical outcomes.

  19. Impact of some environmental conditions on the tensile, creep-recovery, relaxation, melting and crystallinity behaviour of UHMWPE-GUR 410-medical grade

    International Nuclear Information System (INIS)

    Mourad, A.-H.I.; Fouad, H.; Elleithy, Rabeh

    2009-01-01

    The present work was undertaken to examine the effect of some environmental media (sodium hydroxide NaOH solution, water, ice, UV irradiation dose and pre-heat treatment) on the mechanical (quasi-static tensile creep-recovery and relaxation) and physical/thermal (melting and crystallinity) behaviour of the ultra high molecular weight polyethylene (UHMWPE-GUR 410-medical grade), that has several biomedical and engineering applications. The results show changes in the mechanical properties due to these environmental effects. The pre-heat treatment has significantly enhanced the tensile properties compared to virgin specimens' properties. Improvement due to pre-heat treatment at 100 o C is more than that at 50 o C. Specimens' storing in ice, NaOH and water has not affected significantly the tensile properties. All properties except fracture strain have enhanced due to specimens exposure to UV irradiation. The differential scanning calorimetry results indicate that environmental media have not any noticeable effects on the melting temperature. However, a significant increase in the degree of crystallinity was observed for all specimens versus that for virgin specimens. The creep and permanent strains of the tested virgin material increase with temperature and lineally increase with applied load. The specimens' exposure to environmental media has improved the creep resistance and the permanent creep strain when compared with that for virgin ones. Remarkable increase was observed in the initial relaxation and residual stress of the exposed specimens against that for virgin specimens.

  20. Estimating the Uncertainty of Tensile Strength Measurement for A Photocured Material Produced by Additive Manufacturing

    Directory of Open Access Journals (Sweden)

    Adamczak Stanisław

    2014-08-01

    Full Text Available The aim of this study was to estimate the measurement uncertainty for a material produced by additive manufacturing. The material investigated was FullCure 720 photocured resin, which was applied to fabricate tensile specimens with a Connex 350 3D printer based on PolyJet technology. The tensile strength of the specimens established through static tensile testing was used to determine the measurement uncertainty. There is a need for extensive research into the performance of model materials obtained via 3D printing as they have not been studied sufficiently like metal alloys or plastics, the most common structural materials. In this analysis, the measurement uncertainty was estimated using a larger number of samples than usual, i.e., thirty instead of typical ten. The results can be very useful to engineers who design models and finished products using this material. The investigations also show how wide the scatter of results is.

  1. Evaluating the Tensile Properties of Aluminum Foundry Alloys through Reference Castings-A Review.

    Science.gov (United States)

    Anilchandra, A R; Arnberg, Lars; Bonollo, Franco; Fiorese, Elena; Timelli, Giulio

    2017-08-30

    The tensile properties of an alloy can be exploited if detrimental defects and imperfections of the casting are minimized and the microstructural characteristics are optimized through several strategies that involve die design, process management and metal treatments. This paper presents an analysis and comparison of the salient characteristics of the reference dies proposed in the literature, both in the field of pressure and gravity die-casting. The specimens produced with these reference dies, called separately poured specimens, are effective tools for the evaluation and comparison of the tensile and physical behaviors of Al-Si casting alloys. Some of the findings of the present paper have been recently developed in the frame of the European StaCast project whose results are complemented here with some more recent outcomes and a comprehensive analysis and discussion.

  2. Evaluating the Tensile Properties of Aluminum Foundry Alloys through Reference Castings—A Review

    Science.gov (United States)

    Anilchandra, A.R.; Arnberg, Lars; Bonollo, Franco; Fiorese, Elena

    2017-01-01

    The tensile properties of an alloy can be exploited if detrimental defects and imperfections of the casting are minimized and the microstructural characteristics are optimized through several strategies that involve die design, process management and metal treatments. This paper presents an analysis and comparison of the salient characteristics of the reference dies proposed in the literature, both in the field of pressure and gravity die-casting. The specimens produced with these reference dies, called separately poured specimens, are effective tools for the evaluation and comparison of the tensile and physical behaviors of Al-Si casting alloys. Some of the findings of the present paper have been recently developed in the frame of the European StaCast project whose results are complemented here with some more recent outcomes and a comprehensive analysis and discussion. PMID:28867796

  3. Specimen Machining for the Study of the Effect of Swelling on CGR in PWR Environment.

    Energy Technology Data Exchange (ETDEWEB)

    Teysseyre, Sebastien Paul [Idaho National Lab. (INL), Idaho Falls, ID (United States)

    2015-06-01

    This report describes the preparation of ten specimens to be used for the study of the effect of swelling on the propagation of irradiation assisted stress corrosion cracking cracks. Four compact tension specimens, four microscopy plates and two tensile specimens were machined from a AISI 304 material that was irradiated up to 33 dpa. The specimens had been machined such as to represent the behavior of materials with 3.7%swelling and <2% swelling.

  4. [Autoshaping of a button-push response and eye movement in human subjects].

    Science.gov (United States)

    Kimura, H; Fukui, I; Inaki, K

    1990-12-01

    Two experiments were conducted with human subjects to investigate the similarities and differences between animal and human behaviors under autoshaping procedures. In these experiments, light served as CS, and display on TV served as US. Whether the pushing button response or gazing response to CS could be obtained in human subjects under Pavlovian conditioning procedure was examined. In Experiment 1, uninstructed naive subjects were placed in a room containing a push-button and a TV display. Within the experimental sessions, the push-button was lit for 8 s as CS, and then paired with the display of a soft pornographic program on TV for 10 s. The result indicated that the modeling of pushing button promoted the increase of response probability among the subjects. The trials conducted after the rest period indicated an increase of response probability. In Experiment 2, a 4 cm square translucent panel was lit for 20 s as CS, and then paired with the display of a computer graphic picture on TV for 8 s as US. Some subjects started gazing at the CS for several seconds. These results indicated that some subjects could acquire the gazing response under the autoshaping procedure.

  5. Evaluation of local deformation behavior accompanying fatigue damage in F82H welded joint specimens by using digital image correlation

    International Nuclear Information System (INIS)

    Nakata, Toshiya; Tanigawa, Hiroyasu

    2012-01-01

    Highlights: ► In tensile, the TIG welded joint material was concentrated in the THAZ. ► In tensile, fracture occurred at the point where the axial strain converged. ► In fatigue, fracture occurred at the point where the Max. shear strain converged. ► Many macrocracks and cavities formed in the FGHAZ and THAZ of the cross section. - Abstract: By using digital image correlation, the deformation behaviors of local domains of F82H joint specimens welded using tungsten inert gas (TIG) and electron beam (EB) welding were evaluated during tensile and fatigue testing. In the tensile test specimens, the tensile strength decreased in the TIG-welded joints, and ductility decreased in both the EB- and TIG-welded joints. Because axial strain increased in the tempered heat-affected zone (HAZ) and led to the fracture of the TIG-welded joint, the strength was considered to have decreased because of welding. In fatigue testing, the number of cycles to fracture for the welded joint decreased to less than 40–60% of that for the base metal. For both fracture specimens, the largest value of shear strain was observed in the region approximately between the fine-grained HAZ and tempered HAZ; this shear strain ultimately led to fracture. Cavities and macrocracks were observed in the fine-grained HAZ and tempered HAZ in the cross sections of the fracture specimens, and geometrical damage possibly resulted in the reduction of fatigue lifetime.

  6. Soft robot design methodology for `push-button' manufacturing

    Science.gov (United States)

    Paik, Jamie

    2018-06-01

    `Push-button' or fully automated manufacturing would enable the production of robots with zero intervention from human hands. Realizing this utopia requires a fundamental shift from a sequential (design-materials-manufacturing) to a concurrent design methodology.

  7. Tensile strength changeability of multilayered composites, fabricated through optimized VARTM Technology, an experimental

    International Nuclear Information System (INIS)

    Nasir, M.A.; Khan, Z.M.

    2016-01-01

    Life span estimation up to tensile fracture of different fiber reinforced composites, Kevlar Fiber Reinforced Polymer (KFRP) and Glass Fiber Reinforced Polymer (GFRP) along with the strain rate effects on dynamic properties is mainly viewed on experimental basis in this paper. Lab-scale Vacuum Assisted Resin Transfer Molding (VARTM) technique is used to fabricate flawless dog bone specimens considering ASTM standard D638-03 and by using LY5052 resin and HY 5052 hardener. In this research, it is tried to maintain 65% of fiber participation in whole specimen composition matrix. Detail design description of VARTM is also discussed and optimized up to maximum scale to acquire compact, uniformly strengthen and porosity banned standard specimens. A conventional stress-strain curve is established to compare the tensile validity of above mentioned competitive composites. Crack Opening Displacement (COD) of research materials after equal intervals of time is observed; results depict the shear stability and reinforcement perfection of these materials. The crack penetration behavior is examined transversely and longitudinally in this research. (author)

  8. Influence of processing parameters on microstructure and tensile properties of TG6 titanium alloy

    International Nuclear Information System (INIS)

    Wang Tao; Guo Hongzhen; Wang Yanwei; Yao Zekun

    2010-01-01

    Research highlights: → This paper highlights the relationships among processing parameters, microstructure and tensile properties of TG6 high temperature titanium alloy. → The microstructural evolutions under different processing parameters were studied by the quantitative metallography, and the effects of microstructure on room and high temperature tensile properties of TG6 alloy were analysed by SEM and TEM. → Linear relationships of elongation vs. volume fraction of primary α phase and ultimate tensile strength vs. thickness of lamellar α phase were determined. - Abstract: Near-isothermal forging of the TG6 titanium alloy was conducted on microprocessor-controlled 630 ton hydraulic press at the deformation temperatures ranging from 850 deg. C to 1045 deg. C, the strain rates of 0.0008 s -1 , 0.003 s -1 and 0.008 s -1 and the deformation degree from 10% to 70%, and then different double heat treatments were applied to the forged specimens. The microstructural evolutions were researched by optical microscope and the microstructural features, i.e. volume fraction of primary α phase and thickness of lamellar α phase, were measured by means of the image analysis software. The room and high temperature tensile properties were obtained for all the specimens. Effects of microstructure on the properties were analysed by scanning electronic microscope. It was found that tenslie properties depended on microstructural features strongly. The plots of ultimate tensile strength vs. thickness of α lamellae and elongation vs. volume fraction of primary α phase produced straight lines. The liner equations were determined by fitting the experimental date, respectively. Compared to other parameters, heat treatment had more influence on the tensile strength and the tensile plasticity was more sensitive to the forging temperature.

  9. The development of a tensile-shear punch correlation for yield properties of model austenitic alloys

    Energy Technology Data Exchange (ETDEWEB)

    Hankin, G.L.; Faulkner, R.G. [Loughborough Univ. (United Kingdom); Hamilton, M.L.; Garner, F.A. [Pacific Northwest National Lab., Richland, WA (United States)

    1997-08-01

    The effective shear yield and maximum strengths of a set of neutron-irradiated, isotopically tailored austentic alloys were evaluated using the shear punch test. The dependence on composition and neutron dose showed the same trends as were observed in the corresponding miniature tensile specimen study conducted earlier. A single tensile-shear punch correlation was developed for the three alloys in which the maximum shear stress or Tresca criterion was successfully applied to predict the slope. The correlation will predict the tensile yield strength of the three different austenitic alloys tested to within {+-}53 MPa. The accuracy of the correlation improves with increasing material strength, to within {+-} MPa for predicting tensile yield strengths in the range of 400-800 MPa.

  10. Development of in-situ rock shear test under low compressive to tensile normal stress

    International Nuclear Information System (INIS)

    Nozaki, Takashi; Shin, Koichi

    2003-01-01

    The purpose of this study is to develop an in-situ rock shear testing method to evaluate the shear strength under low normal stress condition including tensile stress, which is usually ignored in the assessment of safety factor of the foundations for nuclear power plants against sliding. The results are as follows. (1) A new in-situ rock shear testing method is devised, in which tensile normal stress can be applied on the shear plane of a specimen by directly pulling up a steel box bonded to the specimen. By applying the counter shear load to cancel the moment induced by the main shear load, it can obtain shear strength under low normal stress. (2) Some model tests on Oya tuff and diatomaceous mudstone have been performed using the developed test method. The shear strength changed smoothly from low values at tensile normal stresses to higher values at compressive normal stresses. The failure criterion has been found to be bi-linear on the shear stress vs normal stress plane. (author)

  11. Effect of conventional and experimental gingival retraction solutions on the tensile strength and inhibition of polymerization of four types of impression materials

    Directory of Open Access Journals (Sweden)

    Sérgio Sábio

    2008-08-01

    Full Text Available In the present study, two types of tests (tensile strength test and polymerization inhibition test were performed to evaluate the physical and chemical properties of four impression materials [a polysulfide (Permlastic, a polyether (Impregum, a condensation silicone (Xantopren and a polyvinylsiloxane (Aquasil ,3; when polymerized in contact with of one conventional (Hemostop and two experimental (Vislin and Afrin gingival retraction solutions. For the tensile strength test, the impression materials were mixed and packed into a steel plate with perforations that had residues of the gingival retraction solutions. After polymerization, the specimens were tested in tensile strength in a universal testing machine. For the polymerization inhibition test, specimens were obtained after taking impressions from a matrix with perforations that contained 1 drop of the gingival retraction solutions. Two independent examiners decided on whether or not impression material remnants remained unpolymerized, indicating interference of the chemical solutions. Based on the analysis of the results of both tests, the following conclusions were reached: 1. The tensile strength of the polysulfide decreased after contact with Hemostop and Afrin. 2. None of the chemical solutions inhibited the polymerization of the polysulfide; 3. The polyether presented lower tensile strength after polymerization in contact with the three gingival retraction agents; 4. The polyether had its polymerization inhibited only by Hemostop; 5. None of the chemical solutions affected the tensile strength of the condensation silicone; 6. Only Hemostop inhibited the polymerization of the condensation silicone; 7. The polyvinylsiloxane specimens polymerized in contact with Hemostop had significantly lower tensile strength; 8. Neither of the chemical solutions (Afrin and Vislin affected the tensile strength of the polyvinylsiloxane and the condensation silicone; 9. Results of the tensile strength

  12. The tensile deformation behavior of nuclear-grade isotropic graphite posterior to hydrostatic loading

    International Nuclear Information System (INIS)

    Yoda, S.; Eto, M.

    1983-01-01

    The effects of prehydrostatic loading on microstructural changes and tensile deformation behavior of nuclear-grade isotropic graphite have been examined. Scanning electron micrographs show that formation of microcracks associated with delamination between basal planes occurs under hydrostatic loading. Hydrostatic loading on specimens results in the decrease in tensile strength and increase in residual strain generated by the applied tensile stress at various levels, indicating that the graphite material is weakened by hydrostatic loading. A relationship between residual strain and applied tensile stress for graphite hydrostatically-loaded at several pressure levels can be approximately expressed as element of= (AP + B) sigmasup(n) over a wide range hydrostatic pressure, where element of, P and sigma denote residual strain, hydrostatic pressure and applied tensile stress, respectively; A, B and n are constant. The effects of prehydrostatic loading on the tensile stress-strain behavior of the graphite were examined in more detail. The ratio of stress after hydrostatic loading to that before hydrostatic loading on the stress-strain relationship remains almost unchanged irrespective of strain. (orig.)

  13. A PC parallel port button box provides millisecond response time accuracy under Linux.

    Science.gov (United States)

    Stewart, Neil

    2006-02-01

    For psychologists, it is sometimes necessary to measure people's reaction times to the nearest millisecond. This article describes how to use the PC parallel port to receive signals from a button box to achieve millisecond response time accuracy. The workings of the parallel port, the corresponding port addresses, and a simple Linux program for controlling the port are described. A test of the speed and reliability of button box signal detection is reported. If the reader is moderately familiar with Linux, this article should provide sufficient instruction for him or her to build and test his or her own parallel port button box. This article also describes how the parallel port could be used to control an external apparatus.

  14. Esophageal button battery ingestions: decreasing time to operative intervention by level I trauma activation.

    Science.gov (United States)

    Russell, Robert T; Griffin, Russell L; Weinstein, Elizabeth; Billmire, Deborah F

    2014-09-01

    The incidence of button battery ingestions is increasing and injury due to esophageal impaction begins within minutes of exposure. We changed our management algorithm for suspected button battery ingestions with intent to reduce time to evaluation and operative removal. A retrospective study was performed to identify and evaluate time to treatment and outcome for all esophageal button battery ingestions presenting to a major children's hospital emergency room from February 1, 2010 through February 1, 2012. During the first year, standard emergency room triage (ST) was used. During the second year, the triage protocol was changed and Trauma I triage (TT) was used. 24 children had suspected button battery ingestions with 11 having esophageal impaction. One esophageal impaction was due to 2 stacked coins. Time from arrival in emergency room to battery removal was 183minutes in ST group (n=4) and 33minutes in TT group (n=7) (p=0.04). One patient in ST developed a tracheoesophageal fistula. There were no complications in the TT group. The use of Trauma 1 activations for suspected button battery ingestions has led to more expedient evaluation and shortened time to removal of impacted esophageal batteries. Copyright © 2014 Elsevier Inc. All rights reserved.

  15. Diametral tensile strength of two dental composites when immersed in ethanol, distilled water and artificial saliva.

    Science.gov (United States)

    Rehman, Abdur; Amin, Faiza; Abbas, Muhammad

    2014-11-01

    To examine the effect of distilled water, artificial saliva and ethanol on the tensile strength of direct tooth-coloured restorative material. The study was conducted at Dr. Ishrat ul Ebad Khan Institute of Oral Health Sciences, Dow University of Health Sciences (DUHS), Karachi, from April 2011 to September 2012. The testing was performed at the Pakistan Council of Scientific and Industrial Research (PCSIR) laboratories. Two composite resins Filtek Z250 and Spectrum TPH were tested. Specimens (13 mm x 3 mm x 2 mm) of each material were prepared in the stainless steel mould according to the manufacturers' instructions and distributed into 3 equal groups: one immersed in distilled water, the other in artificial saliva, and the last one in ethanol for 24 hours. Tensile strength was determined after 24 hours in universal Instron Testing Machine. There were 72 specimens in all; 36 (50%) each for Filtek Z250 and Spectrum TPH. The three sub-groups in each case had 12 (33.3%) specimens. For the Filtek Z250, there was no statistically significant difference between immersion in distilled water and artificial saliva, but the ethanol group presented lower tensile strength (ptensile strength compared to distilled water (ptested composite resins were affected by the immersion media and adversely affected the mechanical properties of composite resins.

  16. On the wearing of anti-nuclear-buttons during working hours

    International Nuclear Information System (INIS)

    Ebel, H.

    1980-01-01

    The paper discusses the controversial jurisdiction on the question as to whether employees or civil servants are allowed to wear so-called anti-nuclear buttons during working hours. Art. 5 of the Basic Law (basic right of freedom of expression) and its limitation by the laws relating to work, civil servants and schools form the legal basis for the admissibility or prohibition of the wearing of political buttons. As far as the factual decision in the individual case is concerned, the author proceeds on the assumption that there is the basic right of equality of Art. 3 of the Basic Law. A teacher who wears the button in school violates the right of equality twice, i.e. not only in his relation with the staff but also in his relation with the pupils. This does not call for the theory of interaction established by the Federal Administrative Court if, in fact, a problem posed by the right of equality is concealed behind the competitive relation of freedom of expression as defined by Art. 5 (1) of the Basic Law and the limitations by the general laws according to Art. 5 (2) of the Basic Law. (HSCH) [de

  17. Investigation of smooth specimen scc test procedures; variations in environment, specimen size, stressing frame, and stress state. [for high strength aluminum alloys

    Science.gov (United States)

    Lifka, B. W.; Sprowls, D. O.; Kelsey, R. A.

    1975-01-01

    The variables studied in the stress-corrosion cracking performance of high strength aluminum alloys were: (1) corrosiveness of the environment, (2) specimen size and stiffness of the stressing system, (3) interpretation of transgranular cracking, and (4) interaction of the state of stress and specimen orientation in a product with an anisotropic grain structure. It was shown that the probability of failure and time to fracture for a specimen loaded in direct tension are influenced by corrosion pattern, the stressing assembly stiffness, and the notch tensile strength of the alloy. Results demonstrate that the combination of a normal tension stress and a shear stress acting on the plane of maximum susceptibility in a product with a highly directional grain cause the greatest tendency for stress-corrosion cracking.

  18. Modelling of the deformation of shot peened cylindrical specimens of 42 CrMo4 in uniaxial tension and deformation and of the resulting macro residual stresses

    International Nuclear Information System (INIS)

    Schulze, V.; Voehringer, O.; Macherauch, E.

    1998-01-01

    Tensile and compressive stress-strain-curves of shot peened and unpeened specimens of quenched and tempered 42 CrMo 4 (AISI 4140) with a diameter of 5 mm only differ in the yield strengths and in the Lueders-deformation. In comparison to the core the regions close to the surface of shot peened cylindrical specimens bear relatively large axial and tangential residual stresses and show different deformation properties. A multi-layer-model was developed to describe both the tensile as well as the compressive deformation behaviour of shot peened cylindrical specimens quantitatively. The calculated transitions from the elastic to the elastic-plastic deformation state during tensile and compressive loading agree quite well with the experimental observations. Also the changes of axial and tangential macro residual stresses after distinct tensile or compressive deformations are in best agreement with the measurements. (orig.)

  19. The development of a tensile-shear punch correlation for yield properties of model austenitic alloys

    International Nuclear Information System (INIS)

    Hankin, G.L.; Faulkner, R.G.; Hamilton, M.L.; Garner, F.A.

    1997-01-01

    The effective shear yield and maximum strengths of a set of neutron-irradiated, isotopically tailored austentic alloys were evaluated using the shear punch test. The dependence on composition and neutron dose showed the same trends as were observed in the corresponding miniature tensile specimen study conducted earlier. A single tensile-shear punch correlation was developed for the three alloys in which the maximum shear stress or Tresca criterion was successfully applied to predict the slope. The correlation will predict the tensile yield strength of the three different austenitic alloys tested to within ±53 MPa. The accuracy of the correlation improves with increasing material strength, to within ± MPa for predicting tensile yield strengths in the range of 400-800 MPa

  20. Evaluation of mechanical properties of construction joint between new and old concrete under combined tensile and shear stresses; Shinkyu concrete no uchitsugime no incho sendan oryokuka no kyodo tokusei no hyoka

    Energy Technology Data Exchange (ETDEWEB)

    Ujiike, I. [Ehime University, Ehime (Japan). Faculty of Engineering; Yoshida, N. [Shikoku Railway Company, Kagawa (Japan); Morishita, S. [Oriental Construction Co. Ltd., Tokyo (Japan)

    1998-01-15

    The objective of this study is to examine the mechanical properties of construction joints between existing and newly placed concrete under combined tensile and shear stresses. Loading tests are conducted by using push off type specimens. The joint surface of existing concrete is roughened by shot blast and a half of the specimen is reconstructed by new concrete using ultra rapid hardening cement. The insufficient treatment of joint surface of the old concrete causes the lowering of tensile rigidity, while shearing rigidity is almost the same as that of the other specimen. The shearing and tensile rigidities of non jointed concrete and concrete shot blasted properly are not dependent on the combination of shearing and tensile forces. For the jointed concrete shot blasted insufficiently, the shearing rigidity decreases with the increase of tensile force and the tensile digidity also becomes lower by the action of shearing force. Both the tensile strength and shearing strength of jointed concrete become small compared to those of non jointed concrete. The ratio of reduction in tensile strength is larger than that in shearing strength. The strength of jointed concrete under combined tensile and shear stresses can be evaluated by Mohr`s failure envelope expressed by parabola tangent to both tensile strength circle and compressive strength circle. 7 refs., 12 figs., 2 tabs.

  1. Tensile and superelastic fatigue characterization of NiTi shape memory cables

    Science.gov (United States)

    Sherif, Muhammad M.; Ozbulut, Osman E.

    2018-01-01

    This paper discusses the tensile response and functional fatigue characteristics of a NiTi shape memory alloy (SMA) cable with an outer diameter of 5.5 mm. The cable composed of multiple strands arranged as one inner core and two outer layers. The results of the tensile tests revealed that the SMA cable exhibits good superelastic behavior up to 10% strain. Fatigue characteristics were investigated under strain amplitudes ranging from 3% to 7% and a minimum of 2500 loading cycles. The evolutions of maximum tensile stress, residual strains, energy dissipation, and equivalent viscous damping under a number of loading cycles were analyzed. The fracture surface of a specimen subjected to 5000 loading cycles and 7% strain was discussed. Functional fatigue test results indicated a very high superelastic fatigue life cycle for the tested NiTi SMA cable.

  2. Tensile properties and fracture of (α+γ) two phase stainless steel with fine grained microstructure

    International Nuclear Information System (INIS)

    Ogiyama, Hiroyuki; Tsukuda, Hitoshi; Soyama, Yoshiro

    1989-01-01

    The tensile properties and fracture of the (α+γ) two phase stainless steel with very fine γ grains were investigated. Two different microstructures with very fine γ grains can be obtianed by the thermomechanical treatments; One has both very fine γ and α grains, and the other has very fine γ and large α grains. The specimens were prepared in quenched and aged (475degC) conditions. The results obtained are as follows. The 0.2 % proof stress and tensile strength increase with the aging at 475degC for all specimens. The refinement of the γ grains plays an important role for the increase of strength in both quenched and aged conditions, and also for the ductility in the quenched condition. The refinement of α grains, however, contributes to the increase of the ductility in the aged condition. Accordingly, it is found that very good combinations of tensile strength and ductility can be achieved by the aging and the refinement of the γ and α grains (micro duplex structure). (author)

  3. EXPERIMENTAL INVESTIGATION ON TENSILE STRENGTH OF JACQUARD KNITTED FABRICS

    Directory of Open Access Journals (Sweden)

    BRAD Raluca

    2015-05-01

    Full Text Available An objective approach to select the best fabric for technical and home textiles consists in mechanical properties evaluation. The goal of this study is to analyze the behavior of knitted fabrics undergoing stretch stress. In this respect, three types of 2 colors Rib structure (backstripes jacquard, twillback jacquard and double-layered 3x3 rib fabric have been presented and tested for tensile strength and elongation on three directions. First, the elasticity and the behavior of knitted Rib fabrics were described The fabrics were knitted using 100% PAN yarns with Nm 1/15x2 on a E5 CMS 330 Stoll V-bed knitting machine, and have been tested using INSTROM 5587 Tensile Testing Machine in respect of standards conditions. After a relaxation period, 15 specimens were prepared, being disposed at 0°, 45 and 90 angles to the wale direction on the flat knitted panel. The tensile strength and the elongation values were recorded and mean values were computed. After strength and tensile elongation testing for 3 types of rib based knitted fabrics, one can see that the double layer knit presents the best mechanical behavior, followed by birds-eyebacking 2 colors Jacquard and then back striped Jacquard. For tensile stress in bias direction, the twillbacking Jacquard has a good breakage resistance value due to the higher number of rib sinker loops in structure that are positioned on the same direction with the tensile force. The twillbacking Jacquard structure could be considered as an alternative for the base material for decorative and home textile products.

  4. Fatigue assessment by energy approach during tensile tests on AISI 304 steel

    Directory of Open Access Journals (Sweden)

    A. Risitano

    2017-01-01

    Full Text Available Estimation of the fatigue limit for steel ductile materials using non-destructive methods is a topic of great interest to researchers today. In recent years, the method adopted has implemented infrared sensors to detect the surface temperature and correlate it with the fatigue limit. In previous paper, a new energy approach was proposed to investigate the fatigue limit during tensile test. The numerical procedure proposed by Chrysochoos is adopted to clean infrared images and applied to analyse the surface heat sources during tensile test. AISI 304 specimens with rectangular cross-sections are tested. Moreover fatigue tests at increasing loads were carried out on steel by a stepwise succession, applied to the same specimen, for applying the thermographic method. The predictions of the fatigue limit, obtained by the analysis of the energy evolution during the static tests, were compared with the predictions obtained applying the thermographic method during fatigue tests.

  5. Analysis of Factors Influencing Measurement Accuracy of Al Alloy Tensile Test Results

    Science.gov (United States)

    Podgornik, Bojan; Žužek, Borut; Sedlaček, Marko; Kevorkijan, Varužan; Hostej, Boris

    2016-02-01

    In order to properly use materials in design, a complete understanding of and information on their mechanical properties, such as yield and ultimate tensile strength must be obtained. Furthermore, as the design of automotive parts is constantly pushed toward higher limits, excessive measuring uncertainty can lead to unexpected premature failure of the component, thus requiring reliable determination of material properties with low uncertainty. The aim of the present work was to evaluate the effect of different metrology factors, including the number of tested samples, specimens machining and surface quality, specimens input diameter, type of testing and human error on the tensile test results and measurement uncertainty when performed on 2xxx series Al alloy. Results show that the most significant contribution to measurement uncertainty comes from the number of samples tested, which can even exceed 1 %. Furthermore, moving from experimental laboratory conditions to very intense industrial environment further amplifies measurement uncertainty, where even if using automated systems human error cannot be neglected.

  6. Summary of the U.S. specimen matrix for the HFIR 13J varying temperature irradiation capsule

    International Nuclear Information System (INIS)

    Zinkle, S.J.

    1998-01-01

    The US specimen matrix for the collaborative DOE/Monbusho HFIR 13J varying temperature irradiation capsule contains two ceramics and 29 different metals, including vanadium alloys, ferritic/martensitic steels, pure iron, austenitic stainless steels, nickel alloys, and copper alloys. This experiment is designed to provide fundamental information on the effects of brief low-temperature excursions on the tensile properties and microstructural evolution of a wide range of materials irradiated at nominal temperatures of 350 and 500 C to a dose of ∼5 dpa. A total of 340 miniature sheet tensile specimens and 274 TEM disks are included in the US-supplied matrix for the irradiation capsule

  7. ZrO2 nanoparticles' effects on split tensile strength of self compacting concrete

    Directory of Open Access Journals (Sweden)

    Ali Nazari

    2010-12-01

    Full Text Available In the present study, split tensile strength of self compacting concrete with different amount of ZrO2 nanoparticles has been investigated. ZrO2 nanoparticles with the average particle size of 15 nm were added partially to cement paste (Portland cement together with polycarboxylate superplasticizer and split tensile strength of the specimens has been measured. The results indicate that ZrO2 nanoparticles are able to improve split tensile strength of concrete and recover the negative effects of polycarboxylate superplasticizer. ZrO2 nanoparticle as a partial replacement of cement up to 4 wt. (% could accelerate C-S-H gel formation as a result of increased crystalline Ca(OH2 amount at the early age of hydration. The increased the ZrO2 nanoparticles' content more than 4 wt. (%, causes the reduced the split tensile strength because of unsuitable dispersion of nanoparticles in the concrete matrix.

  8. Tensile behavior of unnotched and notched tungsten--copper laminar composites

    International Nuclear Information System (INIS)

    Hoffman, C.A.

    1976-06-01

    Relations were studied between the tensile strengths of unnotched and of notched, and elastic moduli of unnotched laminar sheet or foil composites and the amounts of reinforcement. Tungsten was used as the reinforcement and copper as the matrix, and the tests were run at room temperature. Three thicknesses of tungsten (i.e., 0.00254, 0.0127, and 0.0254 cm (0.001, 0.005, and 0.010 in) were used, and the nominal volume fraction of tungsten was varied from about 0.05 to 0.95. It was found that the tensile strength of the unnotched specimens could be related to the amount of reinforcement, as could the elastic moduli, and that these values could be predicted by use of the rule of mixtures. The tensile strengths of the notched laminar composites could be predicted by use of the rule of mixtures using strengths for notched constituents, provided notch effects did not predominate. (Author)

  9. Multidimensional flow, thermal, and chemical behavior in solid-oxide fuel cell button cells

    Energy Technology Data Exchange (ETDEWEB)

    Goldin, Graham M. [Ansys Incorporated, 10 Cavendish Ct., Centerra Resource Park, Lebanon, NH 03766 (United States); Zhu, Huayang; Kee, Robert J. [Engineering Division, Colorado School of Mines, Golden, CO 80401 (United States); Bierschenk, David; Barnett, Scott A. [Materials Science, Northwestern University, Evanston, IL 60208 (United States)

    2009-02-01

    The quantitative analysis and interpretation of button-cell experiments usually depends upon assuming isothermal conditions together with uniform and known gas composition within the gas compartments. An objective of the present effort is to develop computational tools to study the validity of such assumptions. A three-dimensional computational fluid dynamics (CFD) model is developed and applied to a particular SOFC button cell, characterizing the fluid flow, chemistry, and thermal transport. Results show that when inlet flow rates are sufficiently high, button-cell data can be interpreted using the commonly used assumptions. However, when flow rates are not sufficient, the assumptions of uniform composition can be significantly violated. Additionally, depending on operating conditions there can be significant temperature variations within the gas compartments and the membrane-electrode assembly. (author)

  10. Measurement of tensile and fracture toughness properties using small punch test

    International Nuclear Information System (INIS)

    Chatterjee, S.; Shah Priti Kotak

    2005-05-01

    Small punch test wu carried out at room temperature on five different steels using 10 mm by 10 mm specimens of 0.4 mm thickness in a univesal testing machine. The tensile and fracture toughness properties of the five steels obtained from small punch test were compared with those obtained from the standard test method. The results (except in one steel) show that the tensile properties obtained from small punch test are in close proximity to those obtained ftom uni-axial tension test. The results also show that fracture toughness (Jic) properties obtained ftom small punch test are within ±20% of the corresponding values obtained using standard test procedures. (author)

  11. Ethylene propylene cable degradation during LOCA research tests: tensile properties at the completion of accelerated aging

    International Nuclear Information System (INIS)

    Bustard, L.D.

    1982-05-01

    Six ethylene-propylene rubber (EPR) insulation materials were aged at elevated temperature and radiation stress exposures common in cable LOCA qualification tests. Material samples were subjected to various simultaneous and sequential aging simulations in preparation for accident environmental exposures. Tensile properties subsequent to the aging exposure sequences are reported. The tensile properties of some, but not all, specimens were sensitive to the order of radiation and elevated temperature stress exposure. Other specimens showed more severe degradation when simultaneously exposed to radiation and elevated temperature as opposed to the sequential exposure to the same stresses. Results illustrate the difficulty in defining a single test procedure for nuclear safety-related qualification of EPR elastomers. A common worst-case sequential aging sequence could not be identified

  12. A study on the compressive and tensile strength of foamed concrete containing pulverized bone as a partial replacement of cement

    International Nuclear Information System (INIS)

    Falade, F.

    2013-01-01

    In this study, structural properties of foamed aerated concrete with and without pulverized bone were investigated. These properties are workability, plastic and testing densities, compressive strength, and tensile strength at the design density of 1600kg/m/sub 3/. The tensile strength was evaluated by subjecting 150 x 150 x750mm unreinforced foamed concrete beams to flexural test and 150x300mm cylinder specimens were subjected to splitting test. 150mm cube specimens were used for the determination of both the compressive strength and the testing density of the foamed aerated concrete. The plastic density was investigated using a container of known volume, and its workability determined using the slump test. The pulverized bone content was varied from 0 to 20% at interval of 5%. The specimens without the pulverized bone served as the control. At the designed density of 1600 kg/m/sub 3/, the results for the control specimens at 28-day curing age are 15.43 and 13.89N/mm/sub 2/ for air-and water-cured specimens respectively. The modulus of rupture and splitting tensile strength are 2.53 and 1.63N/mm/sub 2/ respectively. The results for specimens with pulverized bone did not differ significantly from the specimens without pulverized bone. From the results of this investigation, it can be concluded that foamed aerated concrete used for this study has potential for structural applications. Also pulverized bone can be used to reduce (partially replace) the quantity of cement used in aerated concrete production; thus ridding our environment of potentially harmful wastes, as well as reduce the consumption of non-renewable resources. (author)

  13. The button effect of CANFLEX bundle on the critical heat flux and critical channel power

    Energy Technology Data Exchange (ETDEWEB)

    Park, Joo Hwan; Jun, Jisu; Suk, Ho Chun [Korea Atomic Energy Research Institute, Taejon (Korea, Republic of); Dimmick, G R; Bullock, D E; Inch, W [Atomic Energy of Canada Limited, Ontario (Canada)

    1998-12-31

    A CANFLEX (CANdu FLEXible fuelling) 43-element bundle has developed for a CANDU-6 reactor as an alternative of 37-element fuel bundle. The design has two diameter elements (11.5 and 13.5 mm) to reduce maximum element power rating and buttons to enhance the critical heat flux (CHF), compared with the standard 37-element bundle. The freon CHF experiments have performed for two series of CANFLEX bundles with and without buttons with a modelling fluid as refrigerant R-134a and axial uniform heat flux condition. Evaluating the effects of buttons of CANFLEX bundle on CHF and Critical Channel Power (CCP) with the experimental results, it is shown that the buttons enhance CCP as well as CHF. All the CHF`s for both the CANFLEX bundles are occurred at the end of fuel channel with the high dryout quality conditions. The CHF enhancement ratio are increased with increase of dryout quality for all flow conditions and also with increase of mass flux only for high pressure conditions. It indicates that the button is a useful design for CANDU operating condition because most CHF flow conditions for CANDU fuel bundle are ranged to high dryout quality conditions. 5 refs., 11 figs. (Author)

  14. The button effect of CANFLEX bundle on the critical heat flux and critical channel power

    Energy Technology Data Exchange (ETDEWEB)

    Park, Joo Hwan; Jun, Jisu; Suk, Ho Chun [Korea Atomic Energy Research Institute, Taejon (Korea, Republic of); Dimmick, G. R.; Bullock, D. E.; Inch, W. [Atomic Energy of Canada Limited, Ontario (Canada)

    1997-12-31

    A CANFLEX (CANdu FLEXible fuelling) 43-element bundle has developed for a CANDU-6 reactor as an alternative of 37-element fuel bundle. The design has two diameter elements (11.5 and 13.5 mm) to reduce maximum element power rating and buttons to enhance the critical heat flux (CHF), compared with the standard 37-element bundle. The freon CHF experiments have performed for two series of CANFLEX bundles with and without buttons with a modelling fluid as refrigerant R-134a and axial uniform heat flux condition. Evaluating the effects of buttons of CANFLEX bundle on CHF and Critical Channel Power (CCP) with the experimental results, it is shown that the buttons enhance CCP as well as CHF. All the CHF`s for both the CANFLEX bundles are occurred at the end of fuel channel with the high dryout quality conditions. The CHF enhancement ratio are increased with increase of dryout quality for all flow conditions and also with increase of mass flux only for high pressure conditions. It indicates that the button is a useful design for CANDU operating condition because most CHF flow conditions for CANDU fuel bundle are ranged to high dryout quality conditions. 5 refs., 11 figs. (Author)

  15. Effect of the Strain Rate on the Tensile Properties of the AZ31 Magnesium Alloy

    International Nuclear Information System (INIS)

    Jeong, Seunghun; Park, Jiyoun; Choi, Ildong; Park, Sung Hyuk

    2013-01-01

    The effect of the strain rate at a range of 10‒4 ⁓ 3 × 10"2s"-1 on the tensile characteristics of a rolled AZ31 magnesium alloy was studied. The normal tensile specimens were tested using a high rate hydraulic testing machine. Specimens were machined from four sheets with different thicknesses, 1, 1.5, 2 and 3 mm, along three directions, 0°, 45°, and 90° to the rolling direction. The results revealed that all the specimens had a positive strain rate sensitivity of strength, that is, the strength increased with increasing strain rate. This is the same tendency as other automotive steels have. Our results suggest that the AZ31 magnesium alloy has better collision characteristics at high strain rates because of improved strength with an increasing strain rate. Ductility decreased with an increasing strain rate with a strain rate under 1 s"-1, but it increased with an increasing strain rate over 1 s"-1. The mechanical properties of the AZ31 magnesium alloy depend on the different microstructures according to the thickness. Two and 3 mm thickness specimens with a coarse and non-uniform grain structure exhibited worse mechanical properties while the 1.5 mm thickness specimens with a fine and uniform grain structure had better mechanical properties. Specimens machined at 0° and 45° to the rolling direction had higher absorbed energy than that of the 90° specimen. Thus, we demonstrate it is necessary to choose materials with proper thickness and machining direction for use in automotive applications.

  16. Effect of helium on the tensile properties of several vanadium alloys

    International Nuclear Information System (INIS)

    Braski, D.N.

    1985-01-01

    Specimens of three vanadium alloys were implanted with different levels of 3 He using the tritium trick and subsequently tensile tested at elevated temperatures. The V-15Cr-5Ti and V-3Ti-1Si specimens were embrittled by 3 He at a level of 150 at. ppm while the VANSTAR-7 specimens were not. The embrittlement appeared to be caused by extensive 3 He bubble networks and possibly precipitate particles on the grain boundaries; hopefully the bubble distribution can be changed (for better simulation) by altering parameters of the tritium trick. The results of the investigation also show that the embrittlement resistance of vanadium alloys can be improved by adjustment of their composition and/or microstructure. 1 reference, 4 figures, 1 table

  17. Delayed system response times affect immediate physiology and the dynamics of subsequent button press behavior.

    Science.gov (United States)

    Kohrs, Christin; Hrabal, David; Angenstein, Nicole; Brechmann, André

    2014-11-01

    System response time research is an important issue in human-computer interactions. Experience with technical devices and general rules of human-human interactions determine the user's expectation, and any delay in system response time may lead to immediate physiological, emotional, and behavioral consequences. We investigated such effects on a trial-by-trial basis during a human-computer interaction by measuring changes in skin conductance (SC), heart rate (HR), and the dynamics of button press responses. We found an increase in SC and a deceleration of HR for all three delayed system response times (0.5, 1, 2 s). Moreover, the data on button press dynamics was highly informative since subjects repeated a button press with more force in response to delayed system response times. Furthermore, the button press dynamics could distinguish between correct and incorrect decisions and may thus even be used to infer the uncertainty of a user's decision. Copyright © 2014 Society for Psychophysiological Research.

  18. Acoustic emission during tensile deformation of M250 grade maraging steel

    Science.gov (United States)

    Mukhopadhyay, Chandan Kumar; Rajkumar, Kesavan Vadivelu; Chandra Rao, Bhaghi Purna; Jayakumar, Tamanna

    2012-05-01

    Acoustic emission (AE) generated during room temperature tensile deformation of varyingly heat treated (solution annealed and thermally aged) M250 grade maraging steel specimens have been studied. Deformation of microstructure corresponding to different heat treated conditions in this steel could be distinctly characterized using the AE parameters such as RMS voltage, counts and peak amplitude of AE hits (events).

  19. Effect of touch screen button size and spacing on touch characteristics of users with and without disabilities.

    Science.gov (United States)

    Sesto, Mary E; Irwin, Curtis B; Chen, Karen B; Chourasia, Amrish O; Wiegmann, Douglas A

    2012-06-01

    The aim of this study was to investigate the effect of button size and spacing on touch characteristics (forces, impulses, and dwell times) during a digit entry touch screen task. A secondary objective was to investigate the effect of disability on touch characteristics. Touch screens are common in public settings and workplaces. Although research has examined the effect of button size and spacing on performance, the effect on touch characteristics is unknown. A total of 52 participants (n = 23, fine motor control disability; n = 14, gross motor control disability; n = 15, no disability) completed a digit entry task. Button sizes varied from 10 mm to 30 mm, and button spacing was 1 mm or 3 mm. Touch characteristics were significantly affected by button size. The exerted peak forces increased 17% between the largest and the smallest buttons, whereas impulses decreased 28%. Compared with the fine motor and nondisabled groups, the gross motor group had greater impulses (98% and 167%, respectively) and dwell times (60% and 129%, respectively). Peak forces were similar for all groups. Button size but not spacing influenced touch characteristics during a digit entry task. The gross motor group had significantly greater dwell times and impulses than did the fine motor and nondisabled groups. Research on touch characteristics, in conjunction with that on user performance, can be used to guide human computer interface design strategies to improve accessibility of touch screen interfaces. Further research is needed to evaluate the effect of the exerted peak forces and impulses on user performance and fatigue.

  20. Weathering effects on tensile and stress rupture strength of glass fiber reinforced vinylester and epoxy thermoset pipes

    Science.gov (United States)

    Nizamuddin, Syed

    Glass fiber reinforced vinylester (GFRE) and epoxy (GFRE) pipes have been used for more than three decades to mitigate corrosion problems in oil fields, chemical and industrial plants. In these services, both GFRV and GFRE pipes are exposed to various environmental conditions. Long-term mechanical durability of these pipes after exposure to environmental conditions, which include natural weathering exposure to seasonal temperature variation, sea water, humidity and other corrosive fluids like crude oil, should be well known. Although extensive research has been undertaken, several major issues pertaining to the performance of these pipes under a number of environmental conditions still remain unresolved. The main objective of this study is to investigate the effects of natural weathering, combined natural weathering with seawater and crude oil exposure, for time periods ranging from 3 to 36 months respectively, on the tensile and stress rupture behavior of GFRV and GFRE pipes. Ring specimens are machined from GFRV and GFRE pipes and tested before and after exposure to different weathering conditions prevalent in the eastern region (Dhahran) of Saudi Arabia and present under service conditions. The natural weathering and combined natural weathering with crude oil exposure of GFRV specimens revealed increased tensile strength even after 36 months of exposure when compared with that of the as received samples. However, the combined natural weathering with seawater exposure of GFRV samples revealed better tensile behavior till 24 months of exposure, and after 36 months their tensile strength was seen to be below that of the as received GFRV samples. The stress rupture behavior of natural weather exposed GFRV samples showed an improvement after 12 months of exposure and it decreased after 24 and 36 months of exposure when compared with the as received GFRV samples. The combined natural weathering with crude oil and seawater exposure of GFRV sample revealed improved

  1. Effect of heat treatments on the tensile and electrical properties of high-strength, high-conductivity copper alloys

    Energy Technology Data Exchange (ETDEWEB)

    Zinkle, S.J.; Eatherly, W.S. [Oak Ridge National Lab., TN (United States)

    1997-08-01

    The unirradiated tensile properties of CuCrZr produced by two different vendors have been measured following different heat treatments. Room temperature electrical resistivity measurements were also performed in order to estimate the thermal conductivity of these specimens. The thermomechanical conditions studied included solution quenched, solution quenched and aged (ITER reference heat treatment), simulated slow HIP thermal cycle ({approximately}1{degrees}C/min cooling from solutionizing temperature) and simulated fast HIP thermal cycle ({approximately}100{degrees}C/min cooling from solutionizing temperature). Specimens from the last two heat treatments were tested in both the solution-cooled condition and after subsequent precipitate aging at 475{degrees}C for 2 h. Both of the simulated HIP thermal cycles caused a pronounced decreases in the strength and electrical conductivity of CuCrZr. The tensile and electrical properties were unchanged by subsequent aging in the slow HIP thermal cycles caused a pronounced decrease in the strength and electrical conductivity of CuCrZr. The tensile and electrical properties were unchanged by subsequent aging in the slow HIP thermal cycle specimens, whereas the strength and conductivity following aging in the fast HIP thermal cycle improved to {approximately}65% of the solution quenched and aged CuCrZr values. Limited tensile and electrical resistivity measurements were also made on two new heats of Hycon 3HP CuNiBe. High strength but poor uniform and total elongations were observed at 500{degrees}C on one of these new heats of CuNiBe, similar to that observed in other heats.

  2. Effect of heat treatments on the tensile and electrical properties of high-strength, high-conductivity copper alloys

    International Nuclear Information System (INIS)

    Zinkle, S.J.; Eatherly, W.S.

    1997-01-01

    The unirradiated tensile properties of CuCrZr produced by two different vendors have been measured following different heat treatments. Room temperature electrical resistivity measurements were also performed in order to estimate the thermal conductivity of these specimens. The thermomechanical conditions studied included solution quenched, solution quenched and aged (ITER reference heat treatment), simulated slow HIP thermal cycle (∼1 degrees C/min cooling from solutionizing temperature) and simulated fast HIP thermal cycle (∼100 degrees C/min cooling from solutionizing temperature). Specimens from the last two heat treatments were tested in both the solution-cooled condition and after subsequent precipitate aging at 475 degrees C for 2 h. Both of the simulated HIP thermal cycles caused a pronounced decreases in the strength and electrical conductivity of CuCrZr. The tensile and electrical properties were unchanged by subsequent aging in the slow HIP thermal cycles caused a pronounced decrease in the strength and electrical conductivity of CuCrZr. The tensile and electrical properties were unchanged by subsequent aging in the slow HIP thermal cycle specimens, whereas the strength and conductivity following aging in the fast HIP thermal cycle improved to ∼65% of the solution quenched and aged CuCrZr values. Limited tensile and electrical resistivity measurements were also made on two new heats of Hycon 3HP CuNiBe. High strength but poor uniform and total elongations were observed at 500 degrees C on one of these new heats of CuNiBe, similar to that observed in other heats

  3. Effect of pre-existing shear bands on the tensile mechanical properties of a bulk metallic glass

    International Nuclear Information System (INIS)

    Cao, Q.P.; Liu, J.W.; Yang, K.J.; Xu, F.; Yao, Z.Q.; Minkow, A.; Fecht, H.J.; Ivanisenko, J.; Chen, L.Y.; Wang, X.D.; Qu, S.X.; Jiang, J.Z.

    2010-01-01

    Bulk Zr 64.13 Cu 15.75 Ni 10.12 Al 10 metallic glass has been rolled at room temperature in two different directions, and the dependences of microstructure and tensile mechanical property on the degree of deformation and rolling directions have been investigated. No deformation-induced crystallization occurs except for shear bands. Shear band formation in conjugated directions is achieved in the specimen rolled in two directions, while rolling in one direction induces shear band formation only in a single direction. Pre-existing properly spaced soft inhomogeneities can stabilize shear bands and lead to tensile plastic strain, and the efficient intersection of shear bands in conjugated directions results in work-hardening behavior, which is further confirmed by in situ tensile scanning electron microscopic observation. Based on the experimental results obtained in two different specimen geometries and finite element analysis, it is deduced that a normal-stress-modified maximum shear stress criterion rather than a shear plane criterion can describe the conditions for the formation of shear bands in uniaxial tension.

  4. Production of small U Alx alloy buttons in a non consumable electrode arc furnace

    International Nuclear Information System (INIS)

    Koshimizu, S.; Lima, L.F.C.P. de; Leal Neto, R.M.

    1994-01-01

    Some results are presented, concerning with composition and phases, in small buttons of U Al x (10 to 50 g) produced in a non consumable electrode arc furnace. The uranium metal utilised is natural one produced in the IPEN. The convenience of the fabrication of small buttons of U AL x is discussed. (author). 3 refs, 2 figs, 1 tab

  5. The effect of thermocycling on tensile bond strength of two soft liners.

    Science.gov (United States)

    Geramipanah, Farideh; Ghandari, Masoumeh; Zeighami, Somayeh

    2013-09-01

    Failure of soft liners depends mostly on separation from the denture base resin; therefore measurement of the bond strength is very important. The purpose of this study was to compare the tensile bond strength of two soft liners (Acropars, Molloplast-B) to denture base resin before and after thermocycling. Twenty specimens fromeach of the two different soft liners were processed according to the manufacturer's instructions between two polymethyl methacrylate (PMMA) sheets. Ten specimens in each group were maintained in 37°C water for 24 hours and 10 were thermocycled (5000 cycles) among baths of 5° and 55°C. The tensile bond strength was measured using a universal testing machine at a crosshead speed of 5 mm/min. Mode of failure was determined with SEM (magnification ×30). Two-way ANOVA was used to analyze the data. The mean and standard deviation of tensile bond strength of Acropars and Molloplast-B before thermocycling were 6.59±1.85 and1.51±0.22 MPa, respectively and 5.89±1.52 and1.37±0.18 MPa, respectively after thermocycling. There was no significant difference before and after thermocycling. Mode of failure in Acropars and Molloplast-B were adhesive and cohesive, respectivley. The bond strength of Acropars was significantly higher than Molloplast-B (P<0.05).

  6. Antibacterial Effect and Tensile Bond Strength of Self-etching Adhesive Resins with and without Methacryloyloxydodecylpyridinium Bromide: An in vitro Study.

    Science.gov (United States)

    Krishnamurthy, Madhuram; Kumar, V Naveen; Leburu, Ashok; Dhanavel, Chakravarthy; Selvendran, Kasiswamy E; Praveen, Nehrudhas

    2018-04-01

    Aim: The aim of the present study was to compare the antibacterial activity of a self-etching primer containing antibacterial monomer methacryloyloxydodecylpyridinium bromide (MDPB) (Clearfil protect bond) with a conventional self-etching primer without MDPB (Clearfil SE bond) against Streptococcus mutans and the effect of incorporation of MDPB on the tensile bond strength of the experimental self-etching primer (Clearfil protect bond). Materials and methods: The antibacterial activity of the self-etching primers was assessed using agar disk diffusion method and the diameters of the zones of inhibition were measured and ranked. For tensile bond strength testing, 20 noncarious human molars were selected and randomly divided into two groups comprising 10 teeth in each group. Group I specimens were treated with Clearfil SE bond (without MDPB). Group II specimens were treated with Clearfil protect bond (with MDPB). Composite material was placed incrementally and cured for 40 seconds in all the specimens. Tensile bond strength was estimated using the Instron Universal testing machine at a crosshead speed of 1 mm/min. Results: The addition of MDPB into a self-etching primer exerts potential antibacterial effect against S. mutans. The tensile bond strength of MDPB containing self-etching primer was slightly lower than that of the conventional self-etching Clearfil protect bond primer, but the difference was not statistically significant. Conclusion: Thus, a self-etching primer containing MDPB will be a boon to adhesive dentistry as it has bactericidal property with adequate tensile bond strength. Clinical significance: The concept of prevention of extension in adhesive dentistry would result in micro/nanoleakage due to the presence of residual bacteria in the cavity. Self-etching primers with MDPB would improve the longevity of such restorations by providing adequate antibacterial activity without compromising the bond strength. Keywords: Antibacterial property

  7. Spectroscopic analysis of radiation-generated changes in tensile properties of a polyetherimide film

    International Nuclear Information System (INIS)

    Long, E.R. Jr.; Long, S.A.T.

    1985-05-01

    The effects of electron radiation on Ultem, a polyetherimide were studied for doses from 2 x 10 to the 9th power to 6 x 10 to the 9th power rad. Specimens were studied for tensile property testing and for electron paramagnetic resonance and infrared spectroscopic measurements of molecular structure. A Faraday cup design and a method for remote temperature measurement were developed. The spectroscopic data show that radiation caused dehydrogenation of methyl groups, rupture of main-chain ether linkage, and opening of imide rings, all to form radicals and indicate that the so-formed atomic hydrogen attached to phenyl radicals, but not to phenoxyl radicals, which would have formed hydroxyls. The observed decays of the radiation-generated phenoxyl, gem-dimethyl, and carbonyl radicals were interpreted as a combining of the radicals to form crosslinking. This crosslinking is the probable cause of the major reduction in the elongation of the tensile specimens after irradiation. Subsequent classical solubility tests indicate that the irradiation caused massive crosslinking

  8. Influence of chemical treatment on the tensile properties of kenaf fiber reinforced thermoplastic polyurethane composite

    Directory of Open Access Journals (Sweden)

    Y. A. El-Shekeil

    2012-12-01

    Full Text Available In this study, the effect of polymeric Methylene Diphenyl Diisocyanate (pMDI chemical treatment on kenaf (Hibiscus cannabinus reinforced thermoplastic polyurethane (TPU/KF was examined using two different procedures. The first consisted of treating the fibers with 4% pMDI, and the second involved 2% NaOH + 4% pMDI. The composites were characterized according to their tensile properties, Fourier Transform Infrared Spectroscopy (FTIR and Scanning Electron Microscopy (SEM. The treatment of the composite with 4% pMDI did not significantly affect its tensile properties, but the treatment with 2% NaOH + 4% pMDI significantly increased the tensile properties of the composite (i.e., 30 and 42% increases in the tensile strength and modulus, respectively. FTIR also showed that treatment with 2% NaOH + 4% pMDI led to the strongest H-bonding. Additionally, the surface morphology of specimens after tensile fracture confirmed that the composite treated with 2% NaOH + 4% pMDI had the best adhesion and wettability.

  9. Tensile testing

    CERN Document Server

    2004-01-01

    A complete guide to the uniaxial tensile test, the cornerstone test for determining the mechanical properties of materials: Learn ways to predict material behavior through tensile testing. Learn how to test metals, alloys, composites, ceramics, and plastics to determine strength, ductility and elastic/plastic deformation. A must for laboratory managers, technicians, materials and design engineers, and students involved with uniaxial tensile testing. Tensile Testing , Second Edition begins with an introduction and overview of the test, with clear explanations of how materials properties are determined from test results. Subsequent sections illustrate how knowledge gained through tensile tests, such as tension properties to predict the behavior (including strength, ductility, elastic or plastic deformation, tensile and yield strengths) have resulted in improvements in materals applications. The Second Edition is completely revised and updated. It includes expanded coverage throughout the volume on a variety of ...

  10. The effect of different light-curing units on tensile strength and microhardness of a composite resin

    Directory of Open Access Journals (Sweden)

    Eduardo Batista Franco

    2007-12-01

    Full Text Available The aim of this study was to evaluate the influence of different light-curing units on the tensile bond strength and microhardness of a composite resin (Filtek Z250 - 3M/ESPE. Conventional halogen (Curing Light 2500 - 3M/ESPE; CL and two blue light emitting diode curing units (Ultraled - Dabi/Atlante; UL; Ultrablue IS - DMC; UB3 and UB6 were selected for this study. Different light intensities (670, 130, 300, and 600 mW/cm², respectively and different curing times (20s, 40s and 60s were evaluated. Knoop microhardness test was performed in the area corresponding to the fractured region of the specimen. A total of 12 groups (n=10 were established and the specimens were prepared using a stainless steel mold composed by two similar parts that contained a cone-shaped hole with two diameters (8.0 mm and 5.0 mm and thickness of 1.0 mm. Next, the specimens were loaded in tensile strength until fracture in a universal testing machine at a crosshead speed of 0.5 mm/min and a 50 kg load cell. For the microhardness test, the same matrix was used to fabricate the specimens (12 groups; n=5. Microhardness was determined on the surfaces that were not exposed to the light source, using a Shimadzu HMV-2 Microhardness Tester at a static load of 50 g for 30 seconds. Data were analyzed statistically by two-way ANOVA and Tukey's test (p<0.05. Regarding the individual performance of the light-curing units, there was similarity in tensile strength with 20-s and 40-s exposure times and higher tensile strength when a 60-s light-activation time was used. Regarding microhardness, the halogen lamp had higher results when compared to the LED units. For all light-curing units, the variation of light-exposure time did not affect composite microhardness. However, lower irradiances needed longer light-activation times to produce similar effect as that obtained with high-irradiance light-curing sources.

  11. The tensile and fatigue properties of type 1.4914 ferritic steel for fusion reactor applications

    International Nuclear Information System (INIS)

    Marmy, P.; Victoria, M.; Ruan, Y.

    1989-08-01

    Martensitic steels have received considerable attention as structural materials in fusion reactor applications. In present designs, fusion reactors are expected to operate in a cyclic mode, thus producing cyclic thermal stresses in the first wall. Due to its thermal expansion coefficient and very low swelling rate, 1.4914 martensitic steel is a suitable candidate for the first wall with high neutron loadings. This paper presents the preirradiation results obtained with subsize-specimens designed to be irradiated with a proton beam in the PIREX facility at the Paul Scherrer Institute (PSI) of Wuerenlingen. Both tensile and low cycle fatigue tests were performed in vacuum in the region from 300 K to 870 K (720 K in the case of fatigue tests). Tensile tests on the subsize specimens (0.33 mm thick) compared well to those on bulk specimens, showing a minimum in ductility at around 620 K. The fatigue tests, performed on tubular specimens (3.4 mm external diameter, 0.35 mm wall thickness) showed substantial softening setting in at a low number of cycles. The initial microstructure observed in transmission microscopy consists of fine martensite laths. As cyclic deformation proceeds, dislocation cells form, that gradually replace the martensitic laths. (author) 19 figs., 5 tabs., 16 refs

  12. A Simulation Model for Tensile Fracture Procedure Analysis of Graphite Material based on Damage Evolution

    International Nuclear Information System (INIS)

    Zhao Erqiang; Ma Shaopeng; Wang Hongtao

    2014-01-01

    Graphite material is generally easy to be damaged by the widely distributed micro-cracks when subjects to load. For numerically analyzing of the structure made of graphite material, the influences of the degradation of the material in damaged areas need to be considered. In this paper, an axial tension test method is proposed to obtain the dynamic damage evolution rule of the material. Using the degradation rule (variation of elastic modulus), the finite element model is then constructed to analyze the tensile fracture process of the L-shaped graphite specimen. An axial tension test of graphite is performed to obtain the stress-strain curve. Based on the variation of the measured curve, the damage evolution rule of the material are fitted out. A simulation model based on the above measured results is then constructed on ABAQUS by user subroutine. Using this simulation model, the tension failure process of L-shaped graphite specimen with fillet are simulated. The calculated and experimental results on fracture load are in good agreement. The damage simulation model based on the stress-strain curve of axial tensile test can be used in other tensile fracture analysis. (author)

  13. Effect of the interfacial adhesion on the tensile and impact properties of carbon fiber reinforced polypropylene matrices

    Directory of Open Access Journals (Sweden)

    Clara Leal Nogueira

    2005-03-01

    Full Text Available Thermoplastic composites have been applied in a wide variety of industrial products, showing recently a great potential to be used in aeronautical field. The objectives of this work were to evaluate the fiber/matrix interface of carbon fiber reinforced polypropylene-based matrices after tensile and impact tests and also to compare the mechanical test results of the manufactured laminates. The laminates were prepared by stacking carbon fiber fabric style Plain Weave (CF and films of four different polypropylene matrices, described as (a polypropylene-PP, (b polypropylene-polyethylene copolymer-PP-PE, (c PP-PE with an interfacial compatibilizer-AM1 and (d PP-PE containing an elastomeric modifier-AM2. The composites were processed using hot compression molding. The mechanical testing results showed that the CF-AM1 laminate family presented the lowest impact strength and the highest tensile strength values when compared to the other laminates. SEM analysis observations of both tensile and impact fractured specimens of the CF-PP/PE-AM1 specimens revealed a stronger fiber/matrix interface. The CF-PP/PE-AM2 laminate showed a lower tensile strength and higher impact strength values when compared to the CF-PP/PE-AM1 one. PP-PE and PP laminates presented the lowest impact strength values.

  14. Pathophysiology of esophageal impairment due to button battery ingestion.

    Science.gov (United States)

    Völker, Johannes; Völker, Christine; Schendzielorz, Philipp; Schraven, Sebastian P; Radeloff, Andreas; Mlynski, Robert; Hagen, Rudolf; Rak, Kristen

    2017-09-01

    The increased use of button batteries with high energy densities in devices of daily life presents a high risk of injury, especially for toddlers and young children. If an accidental ingestion of a button battery occurs, this foreign body can become caught in the constrictions of the esophagus and cause serious damage to the adjacent tissue layers. The consequences can be ulcerations, perforations with fistula formation and damage to the surrounding anatomical structures. In order to gain a better understanding of the pathophysiology after ingestion, we carried out systematic studies on fresh preparations of porcine esophagi. The lithium button battery type CR2032, used most frequently in daily life, was exposed in preparations of porcine esophagi and incubated under the addition of artificial saliva at 37 °C. A total of eight esophagi were analysed by different methods. Measurements of the pH value around the battery electrodes and histological studies of the tissue damage were carried out after 0.5-24 h exposure time. In addition, macroscopic time-lapse images were recorded. Measurements of the battery voltage and the course of the electric current supplemented the experiments. The investigations showed that the batteries caused an electrolysis reaction in the moist environment. The positive electrode formed an acidic and the negative electrode a basic medium. Consequently, a coagulation necrosis at the positive pole, and a deep colliquation necrosis at the minus pole occurred. After an exposure time of 12 h, tissue damage caused by the lye corrosion was observed on the side of the negative electrode up to the lamina muscularis. The corrosion progressed up to the final exposure time of 24 h, but the batteries still had sufficient residual voltage, such that further advancing damage would be expected. Button battery ingestion in humans poses an acute life-threatening danger and immediate endoscopic removal of the foreign body is essential. After only 2

  15. Evaluation of A-1 reactor heavy-water calandria specimens

    International Nuclear Information System (INIS)

    Brumovsky, M.

    1976-01-01

    Container chains with surveillance specimens were placed in two special channels of the core peripheral part to test changes in mechanical properties due to reactor operation of caisson tube material. The specimens were made from the caisson tube material and placed by eight pieces on the outer surface of the containers. The first removed specimens were tested for corrosion losses, tensile strength, and fractured surfaces were then assessed. The changes in strength properties were found to be similar in both base material and welded joints. The corrosion film on surveillance specimens did not practically affect strength properties nor ductility. It was found that the Al-Mg-Si alloy used for the heavy water vessel caisson tubes following stabilization annealing was fully stable at operating temperatures of up to 100 degC. Slio.ht changes in properties can be attributed to the effect of a high neutron dose. Thus, the high radiation and temperature stability of the alloy was confirmed. (O.K.)

  16. Characterizing occipital condyle loads under high-speed head rotation.

    Science.gov (United States)

    Pintar, Frank A; Yoganandan, Narayan; Baisden, Jamie

    2005-11-01

    Because of the need to evaluate anthropomorphic test device (ATD) biofidelity under high-head angular accelerations, the purpose of the present investigation was to develop appropriate instrumentation for intact post mortem human subject (PMHS) testing, validate the instrumentation, and obtain information to characterize the response of the head-neck complex under this loading scenario. A series of rigid-arm pendulum, inertially loaded ATD tests was conducted. Head and neck ATD hydraulic piston chin pull tests were conducted. Subsequently, a series of PMHS tests was conducted to derive the response of the human head-neck under high-rate chin loading. Finally, Hybrid III and THOR-NT ATD head-neck systems were evaluated under the same scenario as the PMHS. A parametric analysis for center of gravity (CG) location and accelerometer orientation determined that even small errors (+/- 3 mm or 2 degrees), produced errors in the force and moment calculations by as much as 17 %. If the moment of inertia (MOI) term was varied by 5 %, resulting moment calculations were affected by as much as 8 %. If the 5 % error in MOI was used to compute occipital condyle moments, and results compared to upper load cell derived moments, peaks differed by as much as 24 %. The head CG and mass MOI should be directly measured for each preparation to obtain accurate results. The injury run on each specimen resulted in predominantly C1-C2 separations or partial separations. The 50(th) percentile probability of AIS=2+ neck injury using tensile force was about 2400 N; for AIS=3+ neck injury the 50(th) percentile risk was about 3180 N. When inserting extension moment as the criteria, the 50(th) percentile probability of an AIS=2+ injury was 51 Nm. The AIS=3+ extension moment at the 50(th) percentile probability was 75 Nm. The new THOR-NT ATD head-neck produced more biofidelic responses with an alternate head-neck junction design compared to the Hybrid III ATD.

  17. Comparative assessment of button cells using a normalized index for potential pollution by heavy metals.

    Science.gov (United States)

    Moreno-Merino, Luis; Jiménez-Hernández, Maria Emilia; de la Losa, Almudena; Huerta-Muñoz, Virginia

    2015-09-01

    Many household batteries worldwide still end up in landfills or are incinerated due to inefficient collection and recycling schemes. Toxic heavy metals from improperly discarded button cells pose a serious risk to human health and the environment, as they can pollute air, soil and water. This paper analyses a series of button cells selected from batteries available on the retail market, and compares their polluting potential. A total of 64 batteries were subjected to chemical analyses of 19 elements - including metals and metalloids - , and energy density measurements. The samples were from four different brands of each of the four most common button cell technologies (alkaline, zinc-air, silver oxide and lithium). An energy-normalized index - the Weighted Potential Pollution Index (WPPI) - was proposed to compare the polluting potential of the different batteries. The higher the battery WPPI score, the greater the content in toxic elements and the lower the energy output. The results of the chemical composition and energy density varied depending on the construction technology of the button cells. However, significant differences in both variables were also found when comparing different brands within the same technology. The differences in WPPI values confirmed the existence of a significant margin to reduce the environmental impact of discarded button cells simply by avoiding the most polluting options. The choice of the battery with the most favourable WPPI produced a reduction in potential pollution of 3-53% for silver oxide batteries, 4-39% for alkaline, 20-28% for zinc-air and 12-26% for lithium. Comparative potential pollution could be assessed when selecting batteries using an energy-normalized index such as WPPI to reduce the environmental impact of improperly disposed button cells. Published by Elsevier B.V.

  18. Effect of salivary pH on diametral tensile strength of glass ionomer cement coated with coating agent

    Science.gov (United States)

    Farahdillah; Triaminingsih, S.; Eriwati, Y. K.

    2017-08-01

    The aim of this study was to analyze the effect of salivary pH to diametral tensile strength of glass ionomer cement (GIC) coated with a coating agent. GIC specimens coated with varnish and nano-filled coating agent were stored in artificial saliva at pH values of 4.5, 5.5, and 7 for 24 h at 37°C, then the diametral tensile strength was tested by universal testing machine. Results showed that there was no significant difference in the diametral tensile strength of the GIC coated with varnish and nano-filled coating agent with decreasing of salivary pH (p salivary pH does not affect the diametral tensile strength of GIC coated by varnish or nano-filled coating agent

  19. Quantitative characterization of the orientation spread within individual grains in copper after tensile deformation

    DEFF Research Database (Denmark)

    Krog-Pedersen, Stine; Bowen, Jacob R.; Pantleon, Wolfgang

    2009-01-01

    By means of electron backscatter diffraction, orientations are determined on a regular grid on a polished section of a copper specimen after tensile deformation to 25%. Individual grains separated by boundaries with disorientation angles above 7° are identified and the microtexture in the form...

  20. Effect of the Strain Rate on the Tensile Properties of the AZ31 Magnesium Alloy

    Energy Technology Data Exchange (ETDEWEB)

    Jeong, Seunghun; Park, Jiyoun; Choi, Ildong [Korea Maritime University, Busan (Korea, Republic of); Park, Sung Hyuk [Korea Institute of Materials Science, Changwon (Korea, Republic of)

    2013-10-15

    The effect of the strain rate at a range of 10‒4 ⁓ 3 × 10{sup 2}s{sup -}1 on the tensile characteristics of a rolled AZ31 magnesium alloy was studied. The normal tensile specimens were tested using a high rate hydraulic testing machine. Specimens were machined from four sheets with different thicknesses, 1, 1.5, 2 and 3 mm, along three directions, 0°, 45°, and 90° to the rolling direction. The results revealed that all the specimens had a positive strain rate sensitivity of strength, that is, the strength increased with increasing strain rate. This is the same tendency as other automotive steels have. Our results suggest that the AZ31 magnesium alloy has better collision characteristics at high strain rates because of improved strength with an increasing strain rate. Ductility decreased with an increasing strain rate with a strain rate under 1 s{sup -}1, but it increased with an increasing strain rate over 1 s{sup -}1. The mechanical properties of the AZ31 magnesium alloy depend on the different microstructures according to the thickness. Two and 3 mm thickness specimens with a coarse and non-uniform grain structure exhibited worse mechanical properties while the 1.5 mm thickness specimens with a fine and uniform grain structure had better mechanical properties. Specimens machined at 0° and 45° to the rolling direction had higher absorbed energy than that of the 90° specimen. Thus, we demonstrate it is necessary to choose materials with proper thickness and machining direction for use in automotive applications.

  1. Measurements of the tensile and compressive properties of micro-concrete used in the Winfrith missile impact experiments

    International Nuclear Information System (INIS)

    Wilson, P.A.

    1982-10-01

    Tests to determine the tensile and compressive properties of a micro-concrete mix are described. The material is a nominally 40MPa ultimate compressive strength concrete used in impact tests with scale models in the prediction of responses in prototype concrete structures. Compressive tests were intended to give complete stress-strain relationships beyond initial failure. Tensile properties were measured by the Brazilian splitting technique and direct tension dog-bone specimens for comparison reasons. (U.K.)

  2. The effect of residual stresses induced by prestraining on fatigue life of notched specimens

    Science.gov (United States)

    Sadeler, R.; Ozel, A.; Kaymaz, I.; Totik, Y.

    2005-06-01

    The effect of tensile prestraining-induced residual stress on the fatigue life of notched steel parts was investigated. The study was performed on AISI 4140 steel. Rotating bending fatigue tests were carried out on semicircular notched specimens with different notch radii in the as-quenched and tempered conditions. Metallography of the specimens was performed by means of light optical microscopy. The finite-element method was used to evaluate the residual stress distribution near the notch region. Fatigue tests revealed fatigue life improvement for notched specimens, which changes depending on the notch radii and applied stress. Scanning electron microscopy was used to examine the fracture surfaces of the specimens.

  3. Comparative assessment of button cells using a normalized index for potential pollution by heavy metals

    Energy Technology Data Exchange (ETDEWEB)

    Moreno-Merino, Luis, E-mail: l.moreno@igme.es [Geological Survey of Spain, Environmental Geology Research Group, C/ Ríos Rosas 23, 28003 Madrid (Spain); Jiménez-Hernández, Maria Emilia; Losa, Almudena de la [Geological Survey of Spain, Environmental Geology Research Group, C/ Ríos Rosas 23, 28003 Madrid (Spain); Huerta-Muñoz, Virginia [Universidad Complutense de Madrid, Departamento de Geodinámica Externa, C/ José Antonio Novais, 12, Ciudad Universitaria, 28040 Madrid (Spain)

    2015-09-01

    Many household batteries worldwide still end up in landfills or are incinerated due to inefficient collection and recycling schemes. Toxic heavy metals from improperly discarded button cells pose a serious risk to human health and the environment, as they can pollute air, soil and water. This paper analyses a series of button cells selected from batteries available on the retail market, and compares their polluting potential. A total of 64 batteries were subjected to chemical analyses of 19 elements — including metals and metalloids — , and energy density measurements. The samples were from four different brands of each of the four most common button cell technologies (alkaline, zinc-air, silver oxide and lithium). An energy-normalized index — the Weighted Potential Pollution Index (WPPI) — was proposed to compare the polluting potential of the different batteries. The higher the battery WPPI score, the greater the content in toxic elements and the lower the energy output. The results of the chemical composition and energy density varied depending on the construction technology of the button cells. However, significant differences in both variables were also found when comparing different brands within the same technology. The differences in WPPI values confirmed the existence of a significant margin to reduce the environmental impact of discarded button cells simply by avoiding the most polluting options. The choice of the battery with the most favourable WPPI produced a reduction in potential pollution of 3–53% for silver oxide batteries, 4–39% for alkaline, 20–28% for zinc-air and 12–26% for lithium. Comparative potential pollution could be assessed when selecting batteries using an energy-normalized index such as WPPI to reduce the environmental impact of improperly disposed button cells. - Highlights: • We compare the polluting potential of button cells using an energy-normalized index. • This battery index considers both chemical

  4. Comparative assessment of button cells using a normalized index for potential pollution by heavy metals

    International Nuclear Information System (INIS)

    Moreno-Merino, Luis; Jiménez-Hernández, Maria Emilia; Losa, Almudena de la; Huerta-Muñoz, Virginia

    2015-01-01

    Many household batteries worldwide still end up in landfills or are incinerated due to inefficient collection and recycling schemes. Toxic heavy metals from improperly discarded button cells pose a serious risk to human health and the environment, as they can pollute air, soil and water. This paper analyses a series of button cells selected from batteries available on the retail market, and compares their polluting potential. A total of 64 batteries were subjected to chemical analyses of 19 elements — including metals and metalloids — , and energy density measurements. The samples were from four different brands of each of the four most common button cell technologies (alkaline, zinc-air, silver oxide and lithium). An energy-normalized index — the Weighted Potential Pollution Index (WPPI) — was proposed to compare the polluting potential of the different batteries. The higher the battery WPPI score, the greater the content in toxic elements and the lower the energy output. The results of the chemical composition and energy density varied depending on the construction technology of the button cells. However, significant differences in both variables were also found when comparing different brands within the same technology. The differences in WPPI values confirmed the existence of a significant margin to reduce the environmental impact of discarded button cells simply by avoiding the most polluting options. The choice of the battery with the most favourable WPPI produced a reduction in potential pollution of 3–53% for silver oxide batteries, 4–39% for alkaline, 20–28% for zinc-air and 12–26% for lithium. Comparative potential pollution could be assessed when selecting batteries using an energy-normalized index such as WPPI to reduce the environmental impact of improperly disposed button cells. - Highlights: • We compare the polluting potential of button cells using an energy-normalized index. • This battery index considers both chemical

  5. Insights into the effects of tensile and compressive loadings on human femur bone.

    Science.gov (United States)

    Havaldar, Raviraj; Pilli, S C; Putti, B B

    2014-01-01

    Fragile fractures are most likely manifestations of fatigue damage that develop under repetitive loading conditions. Numerous microcracks disperse throughout the bone with the tensile and compressive loads. In this study, tensile and compressive load tests are performed on specimens of both the genders within 19 to 83 years of age and the failure strength is estimated. Fifty five human femur cortical samples are tested. They are divided into various age groups ranging from 19-83 years. Mechanical tests are performed on an Instron 3366 universal testing machine, according to American Society for Testing and Materials International (ASTM) standards. The results show that stress induced in the bone tissue depends on age and gender. It is observed that both tensile and compression strengths reduces as age advances. Compressive strength is more than tensile strength in both the genders. The compression and tensile strength of human femur cortical bone is estimated for both male and female subjecting in the age group of 19-83 years. The fracture toughness increases till 35 years in male and 30 years in female and reduces there after. Mechanical properties of bone are age and gender dependent.

  6. Tensile Bond Strength of Self Adhesive Resin Cement After Various Surface Treatment of Enamel.

    Science.gov (United States)

    Sekhri, Sahil; Mittal, Sanjeev; Garg, Sandeep

    2016-01-01

    In self adhesive resin cements adhesion is achieved to dental surface without surface pre-treatment, and requires only single step application. This makes the luting procedure less technique-sensitive and decreases postoperative sensitivity. The purpose of this study was to evaluate bond strength of self adhesive resin after surface treatment of enamel for bonding base metal alloy. On the labial surface of 64 central incisor rectangular base metal block of dimension 6 mm length, 5mm width and 1 mm height was cemented with RelyX U200 and Maxcem Elite self adhesive cements with and without surface treatment of enamel. Surface treatment of enamel was application of etchant, one step bonding agent and both. Tensile bond strength of specimen was measured with universal testing machine at a cross head speed of 1mm/min. Least tensile bond strength (MPa) was in control group i.e. 1.33 (0.32) & 1.59 (0.299), Highest bond strength observed when enamel treated with both etchant and bonding agent i.e. 2.72 (0.43) & 2.97 (0.19) for Relyx U200 and Elite cement. When alone etchant and bonding agent were applied alone bond strength is 2.19 (0.18) & 2.24 (0.47) for Relyx U200, and 2.38 (0.27) 2.49 (0.16) for Max-cem elite. Mean bond strength was higher in case of Max-cem Elite as compared to RelyX U200 resin cement, although differences were non-significant (p > 0.05). Surface treatment of enamel increases the bond strength of self adhesive resin cement.

  7. Modeling the impact of pedestrian behavior diversity on traffic dynamics at a crosswalk with push button

    Science.gov (United States)

    Xie, Dong-Fan; Zhao, Xiao-Mei; Li, Xin-Gang; Zhu, Tai-Lang

    2016-01-01

    Crosswalk with push button is prevalent in lots of cities for the purpose of promoting the efficiency of the crosswalk, and thus the delays of both vehicles and pedestrians can be reduced. This strategy has been confirmed to be effective in several developed countries. However, it is a pity that application of push button is aborted in some cities in China. In this work, diverse behaviors of vehicles and pedestrians are analyzed and discussed. Then, a microscopic model is developed by incorporating the interaction between vehicles and pedestrians. Numerical simulations are performed to reveal the characteristics of traffic flow and the efficiency of the signal control strategy. Also, the impacts of risker proportion and button reaction time, as well as the impacts of various behaviors as mass behavior, the patience of pedestrian and push button habit are investigated. It is expected that the results will be helpful to the strategy design of a signalized crosswalk in such developing countries as China.

  8. Tensile properties of helium-injected V-15Cr-5Ti after irradiation in EBR-II

    International Nuclear Information System (INIS)

    Grossbeck, M.L.; Horak, J.A.

    1985-01-01

    Miniature specimens of V-15Cr-5Ti were prepared in the annealed condition and with 10, 20, and 30% cold work. The annealed specimens were cyclotron injected with helium and irradiated in sodium in EBR-II. The cold-worked specimens were irradiated in EBR-II but not helium injected. The specimens were irradiated at 400, 525, 625, and 700 0 C and received a fluence of 4.1 to 5.5 x 10 26 neutrons/m 2 (E > 0.1 meV). Tensile testing revealed very significant embrittlement as a result of the neutron irradiation but a much smaller change, mostly at 400 0 C, resulting from helium injection. 5 references, 9 figures, 2 tables

  9. The Effect of Corrosive Environment on Geopolymer Concrete Tensile Strength

    Directory of Open Access Journals (Sweden)

    Bayuaji Ridho

    2017-01-01

    Full Text Available This study has the purpose to explore the potential of geopolymer concrete tensile strength in particular on the effects of corrosive environments. Geopolymer concrete, concrete technology used no OPC that has advantages, one of which is durability, especially for corrosive seawater environment. In addition, geopolymer concrete with polymerization mechanism does not require large energy consumption or an environmentally friendly concept. Geopolymer concrete in this study is using a type C fly ash from PT. International Power Mitsui Operation & Maintenence Indonesia (IPMOMI Paiton. The type of alkaline activator used NaOH (14 molar and Na2SiO3. Coarse and fine aggregate used are local aggregate. Geopolymer concrete molded test specimen with dimensions of (10 × 20 cm cylinder, further heating and without heating, then maintained at room temperature and seawater up to 28 days. Then to determine the mechanical properties, the tensile strength testing is done with reference. This result of study indicates the curing of geopolymer concrete at 60 ° C for 24 hours to raise the tensile strength of geopolymer concrete.

  10. Evaluation of miniature tension specimen fabrication techniques and performance

    International Nuclear Information System (INIS)

    Hamilton, M.L.; Blotter, M.A.; Edwards, D.J.

    1993-01-01

    The confident application of miniature tensile specimens requires adequate control over their fabrication and is facilitated by automated test and analysis techniques. Three fabrication processes -- punching, chemical milling, and electrical discharge machining (EDM) -- were recently evaluated, leading to the replacement of the previously used punching technique with a wire EDM technique. The automated data acquisition system was upgraded, and an interactive data analysis program was developed

  11. Peach fruit set and buttoning after spring frost

    Science.gov (United States)

    A spring frost occurred on 29 Mar. 2015 at the USDA-ARS Byron station after three weeks of blooming when most fruitlets were forming. Due to severe fruitlet drop, the overall fruit set on a scale of 0-9 was substantially reduced, from 5.61 averaged in 2014 to 2.61 in 2015. In addition, buttons (abno...

  12. Comparative Evaluation of Tensile Strength in Die Stone Incorporated with Sodium and Calcium Hypochlorite as Disinfectants: An in vitro Study.

    Science.gov (United States)

    Pramodh, N R; Kumar, C N Vijay; Pradeep, M R; Naik, Ravi; Mahesh, C S; Kumari, Manju R

    2017-12-01

    The aim of this study was to evaluate the tensile strength of die stone incorporated with sodium and calcium hypochlorite as disinfectants. Two commercially available type IV die stone (Kalrock: Kalabhai Karson Pvt., Ltd and Pearlstone: Asian Chemicals) and two commercially available disinfectant solutions (sodium hypochlorite and calcium hypochlorite: Beachem Laboratory Chemical Private Limited, Chennai and Leo Chem Private Limited, Bengaluru) were used in this study, and the tensile strength was measured using Lloyd's Universal Testing Machine. The results show that incorporating the disinfecting solutions decreases the tensile strength of both products. The effect of decreasing tensile strength on type IV gypsum product is seen more in calcium hypochlorite when compared with sodium hypochlorite disinfecting solution, and the tensile strength of Kalrock specimens is higher than Pearlstone specimens after disinfecting with sodium hypochlorite and calcium hypochlorite solution. The statistical results also show significant results in all the groups when compared with the control group. The incorporation of sodium and calcium hypochlorite disinfecting solutions is not an encouraging method for both die materials as it reduces the tensile strength of type IV gypsum product. Tensile strength of Kalstone® die material is superior than Pearlstone® die material after mixing with sodium hypochlorite and calcium hypochlorite. According to the recommendations of Americans with Disability Act (ADA) and the Centers for Disease Control and Prevention, disinfecting the whole cast without or minimal changes in physical and mechanical properties was the motto of the study. The tensile strength in type IV gypsum product plays a most important role in retrieval of cast from impression, especially in narrow tooth preparation. This study reveals that incorporating method of disinfecting solutions is not recommended as it reduces the tensile strength.

  13. Elevated-temperature tensile properties of 2 1/4 Cr-1 Mo steel irradiated in the EBR-II, AD-2 experiment

    International Nuclear Information System (INIS)

    Klueh, R.L.; Vitek, J.M.

    1984-01-01

    The effect of irradiated on the tensile properties of 2 1/4 Cr-1 Mo steel was determined for specimens irradiation in EBR-II at 390 to 550 0 C. Unirradiated control specimens and specimens aged for 5000 h at the irradiation temperatures were also tested. Irradiation to approximately 9 dpa at 390 0 C increased the strength and decreased the ductility compared with the unirradiated and aged specimens. Softening occurred in samples irradiated and tested at 450, 500, and 550 0 C

  14. Response-related potentials during semantic priming: the effect of a speeded button response task on ERPs.

    Directory of Open Access Journals (Sweden)

    Marijn van Vliet

    Full Text Available This study examines the influence of a button response task on the event-related potential (ERP in a semantic priming experiment. Of particular interest is the N400 component. In many semantic priming studies, subjects are asked to respond to a stimulus as fast and accurately as possible by pressing a button. Response time (RT is recorded in parallel with an electroencephalogram (EEG for ERP analysis. In this case, the response occurs in the time window used for ERP analysis and response-related components may overlap with stimulus-locked ones such as the N400. This has led to a recommendation against such a design, although the issue has not been explored in depth. Since studies keep being published that disregard this issue, a more detailed examination of influence of response-related potentials on the ERP is needed. Two experiments were performed in which subjects pressed one of two buttons with their dominant hand in response to word-pairs with varying association strength (AS, indicating a personal judgement of association between the two words. In the first experiment, subjects were instructed to respond as fast and accurately as possible. In the second experiment, subjects delayed their button response to enforce a one second interval between the onset of the target word and the button response. Results show that in the first experiment a P3 component and motor-related potentials (MRPs overlap with the N400 component, which can cause a misinterpretation of the latter. In order to study the N400 component, the button response should be delayed to avoid contamination of the ERP with response-related components.

  15. Tensile mechanical properties of a stainless steel irradiated up to 19 dpa in the Swiss spallation neutron source

    Energy Technology Data Exchange (ETDEWEB)

    Saito, Shigeru, E-mail: saito.shigeru@jaea.go.jp [JAEA, J-PARC Center, Tokai-mura, Ibaraki-ken 319-1195 (Japan); Kikuchi, Kenji [Ibaraki Univ., iFRC, Tokai-mura, Ibaraki-ken 319-1106 (Japan); Hamaguchi, Dai [JAEA, J-PARC Center, Tokai-mura, Ibaraki-ken 319-1195 (Japan); Usami, Kouji; Endo, Shinya; Ono, Katsuto; Matsui, Hiroki [JAEA, Dept. of Hot Laboratories, Tokai-mura, Ibaraki-ken 319-1195 (Japan); Kawai, Masayoshi [KEK, Tsukuba-shi, Ibaraki-ken 305-0801 (Japan); Dai, Yong [PSI, Spallation Source Division, Villigen PSI (Switzerland)

    2012-12-15

    To evaluate the lifetime of the beam window of an accelerator-driven transmutation system (ADS), post irradiation examination (PIE) of the STIP (SINQ target irradiation program, SINQ; Swiss spallation neutron source) specimens was carried out. The specimens tested in this study were made from the austenitic steel Japan primary candidate alloy (JPCA). The specimens were irradiated at SINQ Target 4 (STIP-II) with high-energy protons and spallation neutrons. The irradiation conditions were as follows: the proton energy was 580 MeV, irradiation temperatures ranged from 100 to 430 Degree-Sign C, and displacement damage levels ranged from 7.1 to 19.5 dpa. Tensile tests were performed in air at room temperature (RT), 250 Degree-Sign C and 350 Degree-Sign C. Fracture surface observation after the tests was done by Scanning electron microscope (SEM). Results of the tensile tests performed at R.T. showed the extra hardening of JPCA at higher dose compared to the fission neutron irradiated data. At the higher temperatures, 250 Degree-Sign C and 350 Degree-Sign C, the extra hardening was not observed. Degradation of ductility bottomed around 10 dpa, and specimens kept their ductility until 19.5 dpa. All specimens fractured in ductile manner.

  16. An Investigation on Tensile Properties of Glass Fiber/Aluminium Laminates

    Directory of Open Access Journals (Sweden)

    M. Sadighi

    2009-12-01

    Full Text Available The idea of combining low weight and good mechanical properties has led to efforts to develop a new light fiber/metal laminate (FML in the last decade. FMLs are hybrid composites consisting of alternating thin layers of metal sheets and fiber-reinforced epoxy prepregs. In this study, the effect of fiber orientation on tensile properties of this material is investigated both analytically and experimentally. An analytical constitutive model based on classical lamination theory by using Kirchhoff-Love assumption, which incorporates the elastic-plastic behavior of the aluminium alloy was applied. Test results show that fiber sheet, with zero angle in laminates, improve the tensile strength. The composite layers with different fiber orientation change specimens' mode of fracture. Good agreement is obtained between the model predictions and experimental results.

  17. Double-button Fixation System for Management of Acute Acromioclavicular Joint Dislocation

    Science.gov (United States)

    Torkaman, Ali; Bagherifard, Abolfazl; Mokhatri, Tahmineh; Haghighi, Mohammad Hossein Shabanpour; Monshizadeh, Siamak; Taraz, Hamid; Hasanvand, Amin

    2016-01-01

    Background: Surgical treatments for acromioclavicular (AC) joint dislocation present with some complications. The present study was designed to evaluate the double-button fixation system in the management of acute acromioclavicular joint dislocation. Methods: This cross sectional study, done between February 2011 to June 2014, consisted of 28 patients who underwent surgical management by the double-button fixation system for acute AC joint dislocation. Age, sex, injury mechanism, dominant hand, side with injury, length of follow up, time before surgery, shoulder and hand (DASH), constant and visual analogue scale (VAS) scores, and all complications of the cases during the follow up were recorded. Results: The mean age of patients was 33.23±6.7 years. Twenty four patients (85.71%) were male and four (14.28%) were female. The significant differences were observed between pre-operation VAS, constant shoulder scores and post-operation measurements. There were not any significant differences between right and left coracoclavicular, but two cases of heterotrophic ossifications were recorded. The mean follow-up time was 16.17±4.38 months. Conclusion: According to the results, the double-button fixation system for management of acute acromioclavicular joint dislocation has suitable results and minimal damage to the soft tissues surrounding the coracoclavicular ligaments. PMID:26894217

  18. Effect of laser shock on tensile deformation behavior of a single crystal nickel-base superalloy

    International Nuclear Information System (INIS)

    Lu, G.X.; Liu, J.D.; Qiao, H.C.; Zhou, Y.Z.; Jin, T.; Zhao, J.B.; Sun, X.F.; Hu, Z.Q.

    2017-01-01

    This investigation focused on the tensile deformation behavior of a single crystal nickel-base superalloy, both in virgin condition and after laser shock processing (LSP) with varied technology parameters. Nanoindention tests were carried out on the sectioned specimens after LSP treatment to characterize the surface strengthening effect. Stress strain curves of tensile specimens were analyzed, and microstructural observations of the fracture surface and the longitudinal cross-sections of ruptured specimens were performed via scanning electron microscope (SEM), in an effort to clarify the fracture mechanisms. The results show that a surface hardening layer with the thickness of about 0.3–0.6 mm was gained by the experimental alloys after LSP treatment, but the formation of surface hardening layer had not affected the yield strength. Furthermore, fundamental differences in the plastic responses at different temperatures due to LSP treatment had been discovered. At 700 °C, the slip deformation was held back when it extended to the surface hardening layer and the ensuing slip steps improved the plasticity; however, at 1000 °C, surface hardening layer hindered the macro necking, which resulted in the relatively lower plasticity.

  19. Effect of laser shock on tensile deformation behavior of a single crystal nickel-base superalloy

    Energy Technology Data Exchange (ETDEWEB)

    Lu, G.X. [Institute of Metal Research, Chinese Academy of Sciences, 72 Wenhua Road, Shenyang 110016 (China); University of Chinese Academy of Sciences, 19 Yuquan Road, Beijing 100049 (China); Liu, J.D., E-mail: jdliu@imr.ac.cn [Institute of Metal Research, Chinese Academy of Sciences, 72 Wenhua Road, Shenyang 110016 (China); Qiao, H.C. [Shenyang Institute of Automation, Chinese Academy of Sciences, 114 Nanta Road, Shenyang 110016 (China); Zhou, Y.Z. [Institute of Metal Research, Chinese Academy of Sciences, 72 Wenhua Road, Shenyang 110016 (China); Jin, T., E-mail: tjin@imr.ac.cn [Institute of Metal Research, Chinese Academy of Sciences, 72 Wenhua Road, Shenyang 110016 (China); Zhao, J.B. [Shenyang Institute of Automation, Chinese Academy of Sciences, 114 Nanta Road, Shenyang 110016 (China); Sun, X.F.; Hu, Z.Q. [Institute of Metal Research, Chinese Academy of Sciences, 72 Wenhua Road, Shenyang 110016 (China)

    2017-02-16

    This investigation focused on the tensile deformation behavior of a single crystal nickel-base superalloy, both in virgin condition and after laser shock processing (LSP) with varied technology parameters. Nanoindention tests were carried out on the sectioned specimens after LSP treatment to characterize the surface strengthening effect. Stress strain curves of tensile specimens were analyzed, and microstructural observations of the fracture surface and the longitudinal cross-sections of ruptured specimens were performed via scanning electron microscope (SEM), in an effort to clarify the fracture mechanisms. The results show that a surface hardening layer with the thickness of about 0.3–0.6 mm was gained by the experimental alloys after LSP treatment, but the formation of surface hardening layer had not affected the yield strength. Furthermore, fundamental differences in the plastic responses at different temperatures due to LSP treatment had been discovered. At 700 °C, the slip deformation was held back when it extended to the surface hardening layer and the ensuing slip steps improved the plasticity; however, at 1000 °C, surface hardening layer hindered the macro necking, which resulted in the relatively lower plasticity.

  20. Small-scale Specimen Testing of Monolithic U-Mo Fuel Foils

    Energy Technology Data Exchange (ETDEWEB)

    Ramprashad Prabhakaran; Douglas E. Burkes; James I. Cole; Indrajit Charit; Daniel M. Wachs

    2008-10-01

    The objective of this investigation is to develop a shear punch testing (SPT) procedure and standardize it to evaluate the mechanical properties of irradiated fuels in a hot-cell so that the tensile behavior can be predicted using small volumes of material and at greatly reduced irradiation costs. This is highly important in the development of low-enriched uranium fuels for nuclear research and test reactors. The load-displacement data obtained using SPT can be interpreted in terms of and correlated with uniaxial mechanical properties. In order to establish a correlation between SPT and tensile data, sub-size tensile and microhardness testing were performed on U-Mo alloys. In addition, efforts are ongoing to understand the effect of test parameters (such as specimen thickness, surface finish, punch-die clearance, crosshead velocity and carbon content) on the measured mechanical properties, in order to rationalize the technique, prior to employing it on a material of unknown strength.

  1. Small-scale Specimen Testing of Monolithic U-Mo Fuel Foils

    International Nuclear Information System (INIS)

    Ramprashad Prabhakaran; Douglas E. Burkes; James I. Cole; Indrajit Charit; Daniel M. Wachs

    2008-01-01

    The objective of this investigation is to develop a shear punch testing (SPT) procedure and standardize it to evaluate the mechanical properties of irradiated fuels in a hot-cell so that the tensile behavior can be predicted using small volumes of material and at greatly reduced irradiation costs. This is highly important in the development of low-enriched uranium fuels for nuclear research and test reactors. The load-displacement data obtained using SPT can be interpreted in terms of and correlated with uniaxial mechanical properties. In order to establish a correlation between SPT and tensile data, sub-size tensile and microhardness testing were performed on U-Mo alloys. In addition, efforts are ongoing to understand the effect of test parameters (such as specimen thickness, surface finish, punch-die clearance, crosshead velocity and carbon content) on the measured mechanical properties, in order to rationalize the technique, prior to employing it on a material of unknown strength

  2. Effect of drivers' age and push button locations on visual time off road, steering wheel deviation and safety perception.

    Science.gov (United States)

    Dukic, T; Hanson, L; Falkmer, T

    2006-01-15

    The study examined the effects of manual control locations on two groups of randomly selected young and old drivers in relation to visual time off road, steering wheel deviation and safety perception. Measures of visual time off road, steering wheel deviations and safety perception were performed with young and old drivers during real traffic. The results showed an effect of both driver's age and button location on the dependent variables. Older drivers spent longer visual time off road when pushing the buttons and had larger steering wheel deviations. Moreover, the greater the eccentricity between the normal line of sight and the button locations, the longer the visual time off road and the larger the steering wheel deviations. No interaction effect between button location and age was found with regard to visual time off road. Button location had an effect on perceived safety: the further away from the normal line of sight the lower the rating.

  3. Numerical Simulation on the Dynamic Splitting Tensile Test of reinforced concrete

    Science.gov (United States)

    Zhao, Zhuan; Jia, Haokai; Jing, Lin

    2018-03-01

    The research for crack resistance was of RC was based on the split Hopkinson bar and numerical simulate software LS-DYNA3D. In the research, the difference of dynamic splitting failure modes between plane concrete and reinforced concrete were completed, and the change rule of tensile stress distribution with reinforcement ratio was studied; also the effect rule with the strain rate and the crack resistance was also discussed by the radial tensile stress time history curve of RC specimen under different loading speeds. The results shows that the reinforcement in the concrete can impede the crack extension, defer the failure time of concrete, increase the tension intensity of concrete; with strain rate of concrete increased, the crack resistance of RC increased.

  4. Effect of grain refinement on the microstructure and tensile properties of thin 319 Al castings

    International Nuclear Information System (INIS)

    Shabani, M.J.; Emamy, M.; Nemati, N.

    2011-01-01

    The structural examinations and tensile properties of thin-section Al castings (319 Al alloy) have been investigated by applying a pattern with different cross sections (2-12 mm). Al-5Ti-1B and Al-5Zr grain refiners were added to the molten Al alloy to produce different levels of Ti (0.01%, 0.05%, 0.1% and 0.15%) and Zr (0.05%, 0.1%, 0.2%, 0.3%, 0.4% and 0.5%) in the castings. From macrostructural studies, it was found that Al-5Zr is less effective in grain refining of 319 alloy in comparison with Al-5Ti-1B master alloy. The optimum levels of grain refiners were selected for determination of tensile properties. T6 heat treatment was applied for selected specimens before tensile testing. Further structural results also showed that thinner sections are less affected by grain refiners. This observation was found to be in a good agreement with tensile test results, where tensile properties of the base and grain refined alloys did not show considerable differences in thinner sections (<6 mm).

  5. Influence of Welding Time on Tensile-Shear Strength of Linear Friction Welded Birch (Betula pendula L. Wood

    Directory of Open Access Journals (Sweden)

    Jussi Ruponen

    2015-04-01

    Full Text Available The purpose of this work was to determine the optimal welding time for linear friction welding of birch (Betula pendula L. wood while keeping the other parameters constant and at similar levels compared to other species in a similar density range. Specimens with dimensions of 20 × 5 × 150 mm3 were welded together, and the influence of welding time (2.5, 3.0, 3.5, and 4.0 s on the mechanical properties of the specimens was determined. The studies included a tensile-shear strength test as well as visual estimation of wood failure percentage (WFP. Additionally, X-ray microtomographic imaging was used to investigate and characterise the bond line properties as a non-destructive testing method. The highest mean tensile-shear strength, 7.9 MPa, was reached with a welding time of 3.5 s. Generally, all four result groups showed high, yet decreasing proportional standard deviations as the welding time increased. X-ray microtomographic images and analysis express the heterogeneity of the weld line clearly as well. According to the averaged group-wise results, WFP and tensile-shear strength correlated positively with an R2 of 0.93. An extrapolation of WFP to 65% totals a tensile-shear strength of 10.6 MPa, corresponding to four common adhesive bonds determined for beech.

  6. Experimental Investigation of Tensile Test on Connection of Cold-formed Cut-curved Steel Section

    Science.gov (United States)

    Sani, Mohd Syahrul Hisyam Mohd; Muftah, Fadhluhartini; Rahman, Nurul Farraheeda Abdul; Fakri Muda, Mohd

    2017-08-01

    Cold-formed steel (CFS) is widely used as structural and non-structural components such as roof trusses and purlin. A CFS channel section with double intermediate web stiffener and lipped is chosen based on the broader usage in roof truss construction. CFS section is cut to form cold-formed pre-cut-curved steel section and lastly strengthened by several types of method or likely known as connection to establish the cold-formed cut-curved steel (CFCCS) section. CFCCS is proposed to be used as a top chord section in the roof truss system. The CFCCS is to resist the buckling phenomena of the roof truss structure and reduced the compression effect on the top chord. The tensile test connection of CFCCS section, especially at the flange element with eight types of connection by welding, plate with self-drilling screw and combination is investigated. The flange element is the weakest part that must be solved first other than the web element because they are being cut totally, 100% of their length for curving process. The testing is done using a universal testing machine for a tensile load. From the experiment, specimen with full welding has shown as a good result with an ultimate load of 13.37 kN and reported having 35.41% when compared with normal specimen without any of connection methods. Furthermore, the experimental result is distinguished by using Eurocode 3. The failure of a full welding specimen is due to breaking at the welding location. Additionally, all specimens with either full weld or spot weld or combination failed due to breaking on weld connection, but specimen with flange plate and self-drilling screw failed due to tilting and bearing. Finally, the full welding specimen is chosen as a good connection to perform the strengthening method of CFCCS section.

  7. Mechanical properties and examination of cracking in TMI-2 pressure vessel lower head material

    International Nuclear Information System (INIS)

    Diercks, D.R.; Neimark, L.A.

    1993-09-01

    Mechanical tests have been conducted on material from 15 samples removed from the lower head of the Three Mile Island unit 2 nuclear reactor pressure vessel. Measured properties include tensile properties and hardness profiles at room temperature, tensile and creep properties at temperatures of 600 to 1200 degrees C, and Charpy V-notch impact properties at -20 to +300 degrees C. These data, which were used in the subsequent analyses of the margin-to-failure of the lower head during the accident, are presented here. In addition, the results of metallographic and scanning electron microscope examinations of cladding cracking in three of the lower head samples are discussed

  8. Tensile behavior of borated stainless steels

    International Nuclear Information System (INIS)

    Stephens, J.J. Jr.; Sorenson, K.B.

    1991-01-01

    Borated stainless steel tensile testing is being conducted at Sandia National Laboratories (SNL). The goal of the test program is to provide data to support a code case inquiry to the ASME Boiler and Pressure Vessel Code, Section III. The adoption by ASME facilitates a material's qualification for structural use in transport cask applications. For transport cask basket applications, the potential advantage to using borated stainless steel arises from the fact that the structural and criticality control functions can be combined into one material. This can result in a decrease in net section thickness of the basket web (increased payload capacity) and eliminates the fabrication process and cost of attaching a discrete boron poison material to the basket web. In addition, adding borate stainless steel to the inventory of acceptable structural material provides the Department of Energy (DOE) and its cask contractors an alternative to current proposed materials which have not been qualified for structural service. The test program at SNL involves procuring material, machining test specimens, and conducting the tensile tests. From test measurements obtained so far, general trends indicate that tensile properties (yield strength and ultimate strength) increase with boron content and are in all cases superior to the minimum required properties established in A-240, Type 304, a typical grade of austenitic stainless steel. Therefore, in a designed basket, web thicknesses using borated stainless steel would be comparable to or thinner tan an equivalent basket manufactured from a typical stainless steel without boron additions. General trends from test results indicate that ductilities decrease with increasing boron content

  9. Tensile and creep data on type 316 stainless steel

    Energy Technology Data Exchange (ETDEWEB)

    Sikka, V. K.; Booker, B. L.P.; Booker, M. K.; McEnerney, J. W.

    1980-01-01

    This report summarizes tensile and creep data on 13 heats of type 316 stainless steel. It includes ten different product forms (three plates, four pipes, and three bars) of the reference heat tested at ORNL. Tensile data are presented in tabular form and analyzed as a function of temperature by the heat centering method. This method yielded a measure of variations within a single heat as well as among different heats. The upper and lower scatter bands developed by this method were wider at the lower temperatures than at the high temperatures (for strength properties), a trend reflected by the experimental data. The creep data on both unaged and aged specimens are presented in tabular form along with creep curves for each test. The rupture time data are compared with the ASME Code Case minimum curve at each test temperature in the range from 538 to 704{sup 0}C. The experimental rupture time data are also compared with the values predicted by using the rupture model based on elevated-temperature ultimate tensile strength. A creep ductility trend curve was developed on the basis of the reference heat data and those published in the literature on nitrogen effects. To characterize the data fully, information was also supplied on vendor, product form, fabrication method, material condition (mill-annealed vs laboratory annealed and aged), grain size, and chemical composition for various heats. Test procedures used for tensile and creep results are also discussed.

  10. Cavitation contributes substantially to tensile creep in silicon nitride

    International Nuclear Information System (INIS)

    Luecke, W.E.; Wiederhorn, S.M.; Hockey, B.J.; Krause, R.F. Jr.; Long, G.G.

    1995-01-01

    During tensile creep of a hot isostatically pressed (HIPed) silicon nitride, the volume fraction of cavities increases linearly with strain; these cavities produce nearly all of the measured strain. In contrast, compressive creep in the same stress and temperature range produces very little cavitation. A stress exponent that increases with stress (var-epsilon ∝ σ n , 2 < n < 7) characterizes the tensile creep response, while the compressive creep response exhibits a stress dependence of unity. Furthermore, under the same stress and temperature, the material creeps nearly 100 times faster in tension than in compression. Transmission electron microscopy (TEM) indicates that the cavities formed during tensile creep occur in pockets of residual crystalline silicate phase located at silicon nitride multigrain junctions. Small-angle X-ray scattering (SAXS) from crept material quantifies the size distribution of cavities observed in TEM and demonstrates that cavity addition, rather than cavity growth, dominates the cavitation process. These observations are in accord with a model for creep based on the deformation of granular materials in which the microstructure must dilate for individual grains t slide past one another. During tensile creep the silicon nitride grains remain rigid; cavitation in the multigrain junctions allows the silicate to flow from cavities to surrounding silicate pockets, allowing the dilation of the microstructure and deformation of the material. Silicon nitride grain boundary sliding accommodates this expansion and leads to extension of the specimen. In compression, where cavitation is suppressed, deformation occurs by solution-reprecipitation of silicon nitride

  11. Strip specimen tests for pipeline materials and girth welds

    Energy Technology Data Exchange (ETDEWEB)

    Mohr, William C. [Edison Welding Institute (EWI), Columbus, Ohio (United States)

    2009-07-01

    Strip specimen testing of pipeline materials has been widely applied as a method of getting data relevant to the performance of pipelines under axial direction loading. Comparisons of strip specimen against smaller standard tests (round tensile bar, fracture toughness specimens, polished round bars) and against full-scale or large-scale testing will be explored. Data from early-generation pipe welds from the 1920's to the 1940's to the most recent materials for offshore reeled pipe will be used for examples. Strip samples can provide full thickness information to take account of varying material properties or imperfection distribution through the thickness. Strip samples can also accommodate measurement of effects of the original surface finish or weld surface shape. Strip samples have more design flexibility than standard tests, but must be designed to limit stress concentrations and effects of local bending. (author)

  12. Effects of contamination by either blood or a hemostatic agent on the shear bond strength of orthodontic buttons

    Science.gov (United States)

    Alkis, Huseyin; Turkkahraman, Hakan

    2013-01-01

    Objective To evaluate the effects of contamination by either blood or a hemostatic agent on the shear bond strength (SBS) of orthodontic buttons. Methods We used 45 freshly extracted, non-carious, impacted third molars that were divided into 3 groups of 15. Each tooth was etched with 37% phosphoric acid gel for 30 s. Human blood or the blood stopper agent was applied to the tooth surface in groups I and II, respectively. Group III teeth were untreated (controls). Orthodontic buttons were bonded to the teeth using light-curing composite resin. After bonding, the SBS of the button was determined using a Universal testing machine. Any adhesive remaining after debonding was assessed and scored according to the modified adhesive remnant index (ARI). ANOVA with post-hoc Tukey's test was used to determine significant differences in SBS and Fisher's exact test, to determine significant differences in ARI scores among groups. Results ANOVA indicated a significant difference between groups (p Contamination of tooth surfaces with either blood or hemostatic agent significantly decreased the SBS of orthodontic buttons. When the contamination risk is high, it is recommended to use the blood stopper agent when bonding orthodontic buttons on impacted teeth. PMID:23671834

  13. Effects of temperature and strain rate on the tensile behaviors of SIMP steel in static lead bismuth eutectic

    Energy Technology Data Exchange (ETDEWEB)

    Liu, Jian, E-mail: jliu12b@imr.ac.cn [Institute of Metal Research, Chinese Academy of Sciences, Shenyang, 110016 (China); University of Chinese Academy of Sciences, Beijing, 100049 (China); Yan, Wei [Institute of Metal Research, Chinese Academy of Sciences, Shenyang, 110016 (China); Sha, Wei [School of Planning, Architecture and Civil Engineering, Queen' s University Belfast, Belfast, BT9 5AG (United Kingdom); Wang, Wei; Shan, Yiyin [Institute of Metal Research, Chinese Academy of Sciences, Shenyang, 110016 (China); Yang, Ke, E-mail: kyang@imr.ac.cn [Institute of Metal Research, Chinese Academy of Sciences, Shenyang, 110016 (China)

    2016-05-15

    In order to assess the susceptibility of candidate structural materials to liquid metal embrittlement, this work investigated the tensile behaviors of ferritic-martensitic steel in static lead bismuth eutectic (LBE). The tensile tests were carried out in static lead bismuth eutectic under different temperatures and strain rates. Pronounced liquid metal embrittlement phenomenon is observed between 200 °C and 450 °C. Total elongation is reduced greatly due to the liquid metal embrittlement in LBE environment. The range of ductility trough is larger under slow strain rate tensile (SSRT) test. - Highlights: • The tensile behaviors of SIMP steel in LBE are investigated for the first time. • The SIMP is susceptible to LME at different strain rates and temperatures. • The total elongation is reduced greatly. • The ductility trough is wider under SSRT. • The tensile specimens rupture in brittle manner without obvious necking.

  14. Effects of temperature and strain rate on the tensile behaviors of SIMP steel in static lead bismuth eutectic

    International Nuclear Information System (INIS)

    Liu, Jian; Yan, Wei; Sha, Wei; Wang, Wei; Shan, Yiyin; Yang, Ke

    2016-01-01

    In order to assess the susceptibility of candidate structural materials to liquid metal embrittlement, this work investigated the tensile behaviors of ferritic-martensitic steel in static lead bismuth eutectic (LBE). The tensile tests were carried out in static lead bismuth eutectic under different temperatures and strain rates. Pronounced liquid metal embrittlement phenomenon is observed between 200 °C and 450 °C. Total elongation is reduced greatly due to the liquid metal embrittlement in LBE environment. The range of ductility trough is larger under slow strain rate tensile (SSRT) test. - Highlights: • The tensile behaviors of SIMP steel in LBE are investigated for the first time. • The SIMP is susceptible to LME at different strain rates and temperatures. • The total elongation is reduced greatly. • The ductility trough is wider under SSRT. • The tensile specimens rupture in brittle manner without obvious necking.

  15. Effect of test temperature on tensile and fatigue properties of nickel-base heat-resistant alloys

    International Nuclear Information System (INIS)

    Tsuji, Hirokazu; Nakajima, Hajime

    1987-01-01

    A series of tensile and strain controlled low-cycle fatigue tests were conducted at temperatures ranging from RT to 900 0 C on a nickel-base heat-resistant alloy, Hastelloy XR-II, which is one of the candidate alloys for applications in the process heating high-temperature gas-cooled reactor (HTGR). Fatigue tests at room temperature and all tensile tests were conducted in air, while fatigue tests at and above 400 0 C were conducted in the simulated HTGR helium environment. In those tests the effect of test temperature on tensile and fatigue properties was investigated. The ductility minimum point was observed near 600 0 C, while tensile and fatigue strengths decreased with increasing test temperature. The fatigue lives estimated with the method proposed by Manson were compatible with the experimental results under the given conditions. For the specimens fatigued at and above 700 0 C, the percentage of the intergranular fracture mode gradually increased with increasing test temperature. (orig.)

  16. Effect of zirconium oxide nanoparticles addition on the optical and tensile properties of polymethyl methacrylate denture base material.

    Science.gov (United States)

    Gad, Mohammed M; Abualsaud, Reem; Rahoma, Ahmed; Al-Thobity, Ahmad M; Al-Abidi, Khalid S; Akhtar, Sultan

    2018-01-01

    Polymethyl methacrylate (PMMA) is widely used for the fabrication of removable prostheses. Recently, zirconium oxide nanoparticles (nano-ZrO 2 ) have been added to improve some properties of PMMA, but their effect on the optical properties and tensile strength are neglected. The aim of this study was to investigate the effect of nano-ZrO 2 addition on the translucency and tensile strength of the PMMA denture base material. Eighty specimens (40 dumbbell-shaped and 40 discs) were prepared out of heat-polymerized acrylic resin and divided into four groups per test (n=10). The control group for each test included unreinforced acrylic, while the test groups were reinforced with 2.5, 5, and 7.5 wt% nano-ZrO 2 . Acrylic resin was mixed according to manufacturer's instructions, packed, and processed by conventional method. After polymerization, all specimens were finished, polished, and stored in distilled water at 37°C for 48±2 hours. Tensile strength (MPa) was evaluated using the universal testing machine while the specimens' translucency was examined using a spectrophotometer. Statistical analysis was carried out by SPSS using the paired sample t -test ( p ≤0.05). A scanning electron microscope was used to analyze the morphological changes and topography of the fractured surfaces. This study showed that the mean tensile strength of the PMMA in the test groups of 2.5%NZ, 5%NZ, and 7.5%NZ was significantly higher than the control group. The tensile strength increased significantly after nano-ZrO 2 addition, and the maximum increase seen was in the 7.5%NZ group. The translucency values of the experimental groups were significantly lower than those of the control group. Within the reinforced groups, the 2.5%NZ group had significantly higher translucency values when compared to the 5%NZ and 7.5%NZ groups. The addition of nano-ZrO 2 increased the tensile strength of the denture base acrylic. The increase was directly proportional to the nano-ZrO 2 concentration. The

  17. High strain rate tensile behavior of Al-4.8Cu-1.2Mg alloy

    International Nuclear Information System (INIS)

    Bobbili, Ravindranadh; Paman, Ashish; Madhu, V.

    2016-01-01

    The purpose of the current study is to perform quasi static and high strain rate tensile tests on Al-4.8Cu-1.2Mg alloy under different strain rates ranging from 0.01–3500/s and also at temperatures of 25,100, 200 and 300 °C. The combined effect of strain rate, temperature and stress triaxiality on the material behavior is studied by testing both smooth and notched specimens. Johnson–Cook (J–C) constitutive and fracture models are established based on high strain rate tensile data obtained from Split hopkinson tension bar (SHTB) and quasi-static tests. By modifying the strain hardening and strain rate hardening terms in the Johnson–Cook (J–C) constitutive model, a new J–C constitutive model of Al-4.8Cu-1.2Mg alloy was obtained. The improved Johnson–Cook constitutive model matched the experiment results very well. With the Johnson–Cook constitutive and fracture models, numerical simulations of tensile tests at different conditions for Al-4.8Cu-1.2Mg alloy were conducted. Numerical simulations are performed using a non-linear explicit finite element code autodyn. Good agreement is obtained between the numerical simulation results and the experiment results. The fracture surfaces of specimens tested under various strain rates and temperatures were studied under scanning electron microscopy (SEM).

  18. Comparison of tensile strength of different carbon fabric reinforced epoxy composites

    Directory of Open Access Journals (Sweden)

    Jane Maria Faulstich de Paiva

    2006-03-01

    Full Text Available Carbon fabric/epoxy composites are materials used in aeronautical industry to manufacture several components as flaps, aileron, landing-gear doors and others. To evaluate these materials become important to know their mechanical properties, for example, the tensile strength. Tensile tests are usually performed in aeronautical industry to determinate tensile property data for material specifications, quality assurance and structural analysis. For this work, it was manufactured four different laminate families (F155/PW, F155/HS, F584/PW and F584/HS using pre-impregnated materials (prepregs based on F155TM and F584TM epoxy resins reinforced with carbon fiber fabric styles Plain Weave (PW and Eight Harness Satin (8HS. The matrix F155TM code is an epoxy resin type DGEBA (diglycidil ether of bisphenol A that contains a curing agent and the F584TM code is a modified epoxy resin type. The laminates were obtained by handing lay-up process following an appropriate curing cycle in autoclave. The samples were evaluated by tensile tests according to the ASTM D3039. The F584/PW laminates presented the highest values of tensile strength. However, the highest modulus results were determined for the 8HS composite laminates. The correlation of these results emphasizes the importance of the adequate combination of the polymeric matrix and the reinforcement arrangement in the structural composite manufacture. The microscopic analyses of the tested specimens show valid failure modes for composites used in aeronautical industry.

  19. Statistical data for the tensile properties of natural fibre composites

    Directory of Open Access Journals (Sweden)

    J.P. Torres

    2017-06-01

    Full Text Available This article features a large statistical database on the tensile properties of natural fibre reinforced composite laminates. The data presented here corresponds to a comprehensive experimental testing program of several composite systems including: different material constituents (epoxy and vinyl ester resins; flax, jute and carbon fibres, different fibre configurations (short-fibre mats, unidirectional, and plain, twill and satin woven fabrics and different fibre orientations (0°, 90°, and [0,90] angle plies. For each material, ~50 specimens were tested under uniaxial tensile loading. Here, we provide the complete set of stress–strain curves together with the statistical distributions of their calculated elastic modulus, strength and failure strain. The data is also provided as support material for the research article: “The mechanical properties of natural fibre composite laminates: A statistical study” [1].

  20. Double-button Fixation System for Management of Acute Acromioclavicular Joint Dislocation

    Directory of Open Access Journals (Sweden)

    Ali Torkaman

    2016-01-01

    Full Text Available Background: Surgical treatments for acromioclavicular (AC joint dislocation present with some complications. The present study was designed to evaluate the double-button fixation system in the management of acute acromioclavicular joint dislocation. Methods: This cross sectional study, done between February 2011 to June 2014, consisted of 28 patients who underwent surgical management by the double-button fixation system for acute AC joint dislocation. Age, sex, injury mechanism, dominant hand, side with injury, length of follow up, time before surgery, shoulder and hand (DASH, constant and visual analogue scale (VAS scores, and all complications of the cases during the follow up were recorded. Results: The mean age of patients was 33.23±6.7 years. Twenty four patients (85.71% were male and four (14.28% were female. The significant differences were observed between pre-operation VAS, constant shoulder scores and post-operation measurements (P=0.001, P=0.0001, P=0.0001, respectively. There were not any significant differences between right and left coracoclavicular (P=0.238, but two cases of heterotrophic ossifications were recorded. The mean follow-up time was 16.17±4.38 months. Conclusion: According to the results, the double-button fixation system for management of acute acromioclavicular joint dislocation has suitable results and minimal damage to the soft tissues surrounding the coracoclavicular ligaments.

  1. Influence of different crosshead speeds on diametral tensile strength of a methacrylate based resin composite: An in-vitro study.

    Science.gov (United States)

    Sood, Anubhav; Ramarao, Sathyanarayanan; Carounanidy, Usha

    2015-01-01

    The aim was to evaluate the influence of different crosshead speeds on diametral tensile strength (DTS) of a resin composite material (Tetric N-Ceram). The DTS of Tetric N-Ceram was evaluated using four different crosshead speeds 0.5 mm/min (DTS 1), 1 mm/min (DTS 2), 5 mm/min (DTS 3), 10 mm/min (DTS 4). A total of 48 specimens were prepared and divided into four subgroups with 12 specimens in each group. Specimens were made using stainless steel split custom molds of dimensions 6 mm diameter and 3 mm height. The specimens were stored in distilled water at room temperature for 24 h. Universal testing machine was used and DTS values were calculated in MPa. Analysis of variance was used to compare the four groups. Higher mean DTS value was recorded in DTS 2 followed by DTS 4, DTS 1, and DTS 3, respectively. However, the difference in mean tensile strength between the groups was not statistically significant (P > 0.05). The crosshead speed variation between 0.5 and 10 mm/min does not seem to influence the DTS of a resin composite.

  2. Tensile properties of irradiated TZM and tungsten

    International Nuclear Information System (INIS)

    Steichen, J.M.

    1975-04-01

    The effect of neutron irradiation on the elevated temperature tensile properties of TZM and tungsten has been experimentally determined. Specimens were irradiated at a temperature of approximately 720 0 F to fluences of 0.4 and 0.9 x 10 22 n/cm 2 (E greater than 0.1 MeV). Test parameters for both control and irradiated specimens included strain rates from 3 x 10 -4 to 1 s -1 and temperatures from 72 to 1700 0 F. The results of these tests were correlated with a rate-temperature parameter (T ln A/epsilon) to provide a concise description of material behavior over the range of deformation conditions of this study. The yield strength of the subject materials was significantly increased by decreasing temperature, increasing strain rate, and increasing fluence. Ductility was significantly reduced at any temperature or strain rate by increasing fluence. Cleavage fractures occurred in both unirradiated and irradiated specimens when the yield strength was elevated to the effective cleavage stress by temperature and/or strain rate. Neutron irradiation for the conditions of this study increased the ductile-to-brittle transition temperature of tungsten by approximately 300 0 F and TZM by approximately 420 0 F. (U.S.)

  3. High-rate tensile behavior of steel fiber-reinforced concrete for nuclear power plants

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Jung Jin; Park, Gi-Joon [Department of Civil and Environmental Engineering, Sejong University, 98 Gunja-Dong, Gwangjin-Gu, Seoul 143-747 (Korea, Republic of); Kim, Dong Joo, E-mail: djkim75@sejong.ac.kr [Department of Civil and Environmental Engineering, Sejong University, 98 Gunja-Dong, Gwangjin-Gu, Seoul 143-747 (Korea, Republic of); Moon, Jae Heum; Lee, Jang Hwa [Korea Institute of Construction Technology, 2311 Daewha-Dong, Ilsan-Gu, Goyang-Si, Gyeonggi-Do 411-712 (Korea, Republic of)

    2014-01-15

    Highlights: • The final goal is to develop a fiber reinforced concrete for containment buildings. • High rate tensile behavior of FRC was investigated. • Strain energy frame impact machine was used for tensile impact tests. • Different rate sensitivity of FRC was found according to the type fiber. • Adding more fibers by increasing S/a is positive for higher impact resistance of FRC. -- Abstract: The direct tensile behavior of fiber-reinforced concrete (FRC) at high strain rates were investigated for their potential to enhance the resistance of the containment building of nuclear power plants (NPPs) against aircraft impact. Two types of deformed steel, hooked (H) and twisted (T) fibers were employed. To improve the tensile resistance of FRCs even at higher rates by adding more fibers, the mixture of concrete was modified by either increasing the sand-to-coarse aggregate ratio or decreasing the maximum size of coarse aggregate. All FRC specimens produced two to six times greater tensile strength and one to five times higher toughness at high strain rates (4–53 s{sup −1}) than those at a static rate (0.000167 s{sup −1}). T-fiber generally produced higher tensile strength and toughness than H-fiber at both static and high rates. Although both fibers showed favorable rate sensitivity, T-fiber produced much greater enhancement, at higher strain rates, in tensile strength and slightly lower enhancement in toughness than H-fiber. As the maximum size of coarse aggregate decreased from 19 to 5 mm, the tensile strength and toughness of FRCs with T-fibers noticeably increased at both static and high strain rates.

  4. Development of micro tensile testing method in an FIB system for evaluating grain boundary strength

    International Nuclear Information System (INIS)

    Fujii, Katsuhiko; Fukuya, Koji

    2010-01-01

    A micro tensile testing method for evaluating grain boundary strength was developed. Specimens of 2 x 2 x 10μm having one grain boundary were made by focused ion beam (FIB) micro-processing and tensioned in an FIB system in situ. The load was measured from the deflection of the silicon cantilever. The method was applied to aged and unaged Fe-Mn-P alloy specimens with different level of grain boundary phosphorus segregation. The load at intergranular fracture decreased with increasing phosphorus segregation. (author)

  5. Strength Prediction and Failure Modes of Concrete Specimens Subjected to the Split Test

    DEFF Research Database (Denmark)

    Hoang, Linh Cao; Andersen, M.E.; Hansen, N.T.

    2014-01-01

    This paper deals with modelling and test of concrete specimens subjected to the Brazilian split test. Based on the fictitious crack concept, a simple model for the crack propagation process in the splitting plane is developed. From the model, it is possible to determine the distribution of residual...... tensile strength as crack propagation take place. The residual tensile strength is thereafter used in a rigid plastic analysis of the splitting failure. Based on this combined approach, the ultimate load may either be governed by crack propagation or by a plastic failure, which then terminates the crack...

  6. THE EFFECT OF PHASE CHANGE MATERIALS ON THE TENSILE STRENGTH

    Directory of Open Access Journals (Sweden)

    HERROELEN Thomas

    2016-05-01

    Full Text Available PCM’s need some important properties to have use such as high heat storage capacity, easy availability and low cost and can have different effects such as flavour, softness or exchange of heat. They are put inside of microcapsules, so they can be inbedded inside the strain, otherwise it wouldn’t be so effective. So basically the microcapsules consist of a core that’s the PCM and a polymer shell. This shell needs to be strong enough to hold the PCM and also withstand up to a certain level of heat and mechanical damage. This study investigates the tensile strength of fabrics composed by fibres, some of these fibres have benn inbedded phase change microcapsules (PCM’s. The investigated fabrics are divided by composition and by structure. By knitting the fabrics in different structures you could be able to investigate which knitting way could be the most effective to have a high tensile strength. Tensile strength tests are performed on specimens with different structures but also with different compositions which could indicate that some strains are tougher then others and more specifically if the PCM’s have a different effect on them.

  7. Material properties of oxide dispersion strengthened (ODS) ferritic steels for core materials of FBR. Tensile properties of sodium exposed and nickel diffused materials

    International Nuclear Information System (INIS)

    Kato, Shoichi; Yoshida, Eiichi

    2002-12-01

    An oxide dispersion strengthened (ODS) ferritic steel is candidate for a long-life core materials of future FBR, because of good swelling resistance and high creep strength. In this study, tensile tests were carried out the long-term extrapolation of sodium environmental effects on the mechanical properties of ODS steels. The tested heats of materials are M93, M11 and F95. The specimens were pre-exposed to sodium for 1,000 and 3,000 hours under non-stress conditions. The pre-exposure to sodium was conducted using a sodium test loop constituted by austenitic steels. For the conditions of sodium exposure test, the sodium temperature was 650 and 700degC, the oxygen concentration in sodium was about 1 ppm and sodium flow rate on the surface of specimen was less than 1x10 -4 m/seconds (nearly static). Further the specimen with the nickel diffused was prepared, which is simulate to nickel diffusing through sodium from the surface of structural stainless steels. The main results obtained were as follows; (1) The tensile strength and the fracture elongation after sodium exposure (maximum 3,000 hours) were same as that of as-received materials. If was considered that the sodium environmental effect is negligible under the condition of this study. (2) Tensile properties of nickel diffused specimens were slightly lower than that of the as-received specimens, but it remains equal to that of thermal aging specimens. (3) The change in microstructure such as a degraded layer was observed on the surface of nickel diffused specimen. In the region of the degraded layer, phase transformations from the α-phase to the γ-phase were recognized. But, the microscopic oxide particles were observed same as that of α-phase base metal. (author)

  8. Compressive and tensile strength for concrete containing coal bottom ash

    Science.gov (United States)

    Maliki, A. I. F. Ahmad; Shahidan, S.; Ali, N.; Ramzi Hannan, N. I. R.; Zuki, S. S. Mohd; Ibrahim, M. H. W.; Azmi, M. A. Mohammad; Rahim, M. Abdul

    2017-11-01

    The increasing demand in the construction industry will lead to the depletion of materials used in construction sites such as sand. Due to this situation, coal bottom ash (CBA) was selected as a replacement for sand. CBA is a by-product of coal combustion from power plants. CBA has particles which are angular, irregular and porous with a rough surface texture. CBA also has the appearance and particle size distribution similar to river sand. Therefore, these properties of CBA make it attractive to be used as fine aggregate replacement in concrete. The objectives of this study were to determine the properties of CBA concrete and to evaluate the optimum percentage of CBA to be used in concrete as fine aggregate replacement. The CBA was collected at Tanjung Bin power plant. The mechanical experiment (compressive and tensile strength test) was conducted on CBA concrete. Before starting the mechanical experiment, cubic and cylindrical specimens with dimensions measuring 100 × 100 × 100 mm and 150 × 300 mm were produced based on the percentage of coal bottom ash in this study which is 0% as the control specimen. Meanwhile 10%, 20%, 30%, 40%, 50%, 60%, 70%, 80%, 90% and 100% of CBA were used to replace the fine aggregates. The CBA concrete samples were cured for 7 days and 28 days respectively to maintain the rate of hydration and moisture. After the experimental work was done, it can be concluded that the optimum percentage of CBA as fine aggregate is 60% for a curing period of both 7 days and 28 days with the total compressive strength of 36.4 Mpa and 46.2 Mpa respectively. However, the optimum percentage for tensile strength is at 70% CBA for a curing period of both 7 days and 28 days with a tensile strength of 3.03 MPa and 3.63 MPa respectively.

  9. Effect of crosslinking UHMWPE on its tensile and compressive creep performance.

    Science.gov (United States)

    Lewis, G; Carroll, M

    2001-01-01

    The in vitro quasi-static tensile and compressive creep properties of three sets of GUR 1050 ultra-high-molecular-weight polyethylene (UHMWPE) specimens were obtained. These sets were: control (as-received stock); "low-gamma" (specimens were crosslinked using gamma radiation, with a minimum dose of 5 Mrad); and "high-gamma" (specimens were crosslinked using gamma radiation, with a minimum dose of 15 Mrad). The % crystallinity (%C) and crosslink density (rho(x)) of the specimens in the three sets were also obtained. It was found that, in both tension and compression, crosslinking resulted in a significant depreciation in the creep properties, relative to control. The trend in the creep results is explained in terms of the impact of crosslinking on the polymer's %C and rho(x). The present results are in contrast to literature reports that show that crosslinking enhances the wear resistance of the polymer. The implications of the present results, taken together with the aforementioned literature results, are fully discussed vis-a-vis the use of crosslinked UHMWPE for fabricating articular components for arthroplasties.

  10. Use of miniature and standard specimens to evaluate effects of irradiation temperature on pressure vessel steels

    International Nuclear Information System (INIS)

    Haggag, F.M.; Nanstad, R.K.; Byrne, S.T.

    1991-01-01

    The effects of neutron irradiation on the steel reactor vessel for the modular high-temperature gas-cooled reactor (MHTGR) are being investigated, primarily because the operating temperatures are low [121 to 210 degrees C (250--410 degrees F)] compared to those for commercial light-water reactors (LWRs) [∼288 degrees C (550 degrees F)]. The need for design data on the reference temperature shift necessitated the irradiation at different temperatures of A 533 grade B class 1 plate. A 508 class 3 forging, and welds used for the vessel shell, vessel closure head, the vessel flange. This paper presents results from the first four irradiation capsules of this program. The four capsules were irradiated in the University of Buffalo Reactor to an effective fast fluence of 1 x10 18 neutron/cm 2 [0.68 x 10 18 neutron/cm 2 (>1 MeV)] at temperatures of 288, 204, 163, and 121 degrees C (550, 400, 325, and 250 degrees F), respectively. The yield and ultimate strengths of both steel plate materials of the MHTGR Program increased with decreasing irradiation temperature. Similarly, the 41-J Charpy V-notch (CVN) transition temperature shift increased with decreasing irradiation temperature (in agreement with the increase in yield strength). The miniature tensile and automated ball indentation (ABI) test results (yield strength and flow properties) were in good agreement with those from standard tensile specimens. The miniature tensile and ABI test results were also used in a model that utilizes the changes in yield strength to estimate the CVN ductile-to-brittle transition temperature shift due to irradiation. The model predictions were compared with CVN test results obtained here and in earlier work. 5 refs., 11 figs., 6 tabs

  11. Tensile Bond Strength of Self Adhesive Resin Cement After Various Surface Treatment of Enamel

    Science.gov (United States)

    Sekhri, Sahil; Garg, Sandeep

    2016-01-01

    Introduction In self adhesive resin cements adhesion is achieved to dental surface without surface pre-treatment, and requires only single step application. This makes the luting procedure less technique-sensitive and decreases postoperative sensitivity. Aim The purpose of this study was to evaluate bond strength of self adhesive resin after surface treatment of enamel for bonding base metal alloy. Materials and Methods On the labial surface of 64 central incisor rectangular base metal block of dimension 6 mm length, 5mm width and 1 mm height was cemented with RelyX U200 and Maxcem Elite self adhesive cements with and without surface treatment of enamel. Surface treatment of enamel was application of etchant, one step bonding agent and both. Tensile bond strength of specimen was measured with universal testing machine at a cross head speed of 1mm/min. Results Least tensile bond strength (MPa) was in control group i.e. 1.33 (0.32) & 1.59 (0.299), Highest bond strength observed when enamel treated with both etchant and bonding agent i.e. 2.72 (0.43) & 2.97 (0.19) for Relyx U200 and Elite cement. When alone etchant and bonding agent were applied alone bond strength is 2.19 (0.18) & 2.24 (0.47) for Relyx U200, and 2.38 (0.27) 2.49 (0.16) for Max-cem elite. Mean bond strength was higher in case of Max-cem Elite as compared to RelyX U200 resin cement, although differences were non–significant (p > 0.05). Conclusion Surface treatment of enamel increases the bond strength of self adhesive resin cement. PMID:26894165

  12. One way to save the number of BPM buttons in the arcs that is not recommended

    International Nuclear Information System (INIS)

    Chao, A.; Kheifets, S.

    1983-12-01

    It has been suggested as a possibility by the beam dynamic task force that the SLC arcs be provided a beam position monitor at every gap between magnets. In this scenario of orbit correction scheme, the BPM's are used alternately for the horizontal and the vertical orbit measurements. One way to construct these BPM's is therefore in the x and y planes. One problem of this construction, as pointed out by Pellegrin and Rees, is that synchrotron radiation will hit the buttons of the x-BPM's. It was suggested then that the x-BPM's should use four buttons, orthogonal, but rotated 45 0 from the x and y planes. This construction requires 4 buttons instead of 2, meaning an increase of cost. As an attempt to reduce the number of buttons needed for arc orbit correction, we have studied a variation of the orbit correction scheme. In this scheme, orbits are not corrected in the x and y coordinates but in the coordinates that are tilted by 45 0 relative to x and y. Let these coordinates be called u and v. The result of the study is that this scheme is not recommended

  13. Humeral head size in shoulder arthroplasty

    DEFF Research Database (Denmark)

    Vaesel, M T; Olsen, Bo Sanderhoff; Søjbjerg, Jens Ole

    1998-01-01

    Changes in kinematics after hemiarthroplasty of the glenohumeral joint were investigated in nine cadaveric specimens. During experiments the influence of the humeral head size on glenohumeral kinematics was evaluated. A modular prosthesis with five different head sizes and press-fit stems was use...

  14. Mass variation effect of teki grass (cyperus rotundus) composite against tensile strength and density

    Science.gov (United States)

    Rafiq Yanhar, Muhammad; Haris Nasution, A.

    2018-05-01

    The primary purpose of this study is to determine the tensile strength using ASTM D638 - 02a type IVB and density of teki grass (Cyperus rotundus) composite. The production process is carried out by mass variation of 2 gr, 3 gr, and 4 gr. Hand lay-up method with three repetitions is applied. Teki grass is chosen because it is easy to find and has some advantages biodegradable, harmless to health, available in large quantities, and cost-efficient. The test result showed the largest tensile strength is 21,61 MPa at 2-gram mass fiber. Fiber addition to 3 gram and 4-gram cause tensile strength decreases to 18,51 MPa and 11,65 MPa. It happens because the fibers are random and spread in all directions, so many fibers are undirectional with the tensile force. Beside that fibers addition made matrix volume reduced and a bond between fiber and matrix decreases, finally make fiber unable to hold the tensile force properly. It is recommended to use another type of ASTM D638 - 02a which has a larger narrow section like type I (13 mm) and type III (19mm) so specimens are not broken when removed from the mold, and there isn’t any decrease in tensile strength.Density test showed that fiber mass does not significantly affect the density.

  15. Study of creep behaviour in P-doped copper with slow strain rate tensile tests

    International Nuclear Information System (INIS)

    Xuexing Yao; Sandstroem, Rolf

    2000-08-01

    Pure copper with addition of phosphorous is planned to be used to construct the canisters for spent nuclear fuel. The copper canisters can be exposed to a creep deformation up to 2-4% at temperatures in services. The ordinary creep strain tests with dead weight loading are generally employed to study the creep behaviour; however, it is reported that an initial plastic deformation of 5-15% takes place when loading the creep specimens at lower temperatures. The slow strain rate tensile test is an alternative to study creep deformation behaviour of materials. Ordinary creep test and slow strain rate tensile test can give the same information in the secondary creep stage. The advantage of the tensile test is that the starting phase is much more controlled than in a creep test. In a tensile test the initial deformation behaviour can be determined and the initial strain of less than 5% can be modelled. In this study slow strain rate tensile tests at strain rate of 10 -4 , 10 -5 , 10 -6 , and 10 -7 /s at 75, 125 and 175 degrees C have been performed on P-doped pure Cu to supplement creep data from conventional creep tests. The deformation behaviour has successfully been modelled. It is shown that the slow strain rate tensile tests can be implemented to study the creep deformation behaviours of pure Cu

  16. Combined near- and far-field high-energy diffraction microscopy dataset for Ti-7Al tensile specimen elastically loaded in situ

    Energy Technology Data Exchange (ETDEWEB)

    Turner, Todd J.; Shade, Paul A.; Bernier, Joel V.; Li, Shiu Fai; Schuren, Jay C.; Lind, Jonathan; Lienert, Ulrich; Kenesei, Peter; Suter, Robert M.; Blank, Basil; Almer, Jonathan

    2016-03-18

    High-energy diffraction microscopy (HEDM) constitutes a suite of combined X-ray characterization methods, which hold the unique advantage of illuminating the microstructure and micromechanical state of a material during concurrent in situ mechanical deformation. The data generated from HEDM experiments provides a heretofore unrealized opportunity to validate meso-scale modeling techniques, such as crystal plasticity finite element modeling (CPFEM), by explicitly testing the accuracy of these models at the length scales where the models predict their response. Combining HEDM methods with in situ loading under known and controlled boundary conditions represents a significant challenge, inspiring the recent development of a new high-precision rotation and axial motion system for simultaneously rotating and axially loading a sample. In this paper, we describe the initial HEDM dataset collected using this hardware on an alpha-titanium alloy (Ti-7Al) under in situ tensile deformation at the Advanced Photon Source, Argonne National Laboratory. We present both near-field HEDM data that maps out the grain morphology and intragranular crystallographic orientations and far-field HEDM data that provides the grain centroid, grain average crystallographic orientation, and grain average elastic strain tensor for each grain. Finally, we provide a finite element mesh that can be utilized to simulate deformation in the volume of this Ti-7Al specimen. The dataset supporting this article is available in the National Institute of Standards and Technology (NIST) repository (http://hdl.handle.net/11256/599).

  17. The difference of tensile bond strength between total and self etch adhesive systems in dentin

    Directory of Open Access Journals (Sweden)

    Selly Yusalina

    2010-03-01

    Full Text Available Total etch adhesive system has been widely used in teeth conservation area as an adhesive agent before implicating composite resin restoration agent. The aim of this research is to prove the difference of tensile bond strength between total etch (Single Bond and self etch adhesive system (Adper prompt L-Pop on dentin surface in vitro. The extracted and non carries maxillary premolar teeth were used in this research and were divided into 2 groups. The first group comprised 15 specimen teeth etched in phosphoric acid and was applicated with the Single Bond adhesive agent. The second group comprised 15 specimen teeth, applicated with the Adper Prompt-L-Pop. The composite resin (Z 350, 3M was applied incrementally and each of the layers was rayed for 20 seconds. The specimens were stored in physiologic solution before they were tested. Tensile bond strength was measured by LRX Plus Lloyd Instrument, with 1 N load and 1 mm/minute speed, and the measurement result was in Mpa unit. The result was evaluated statistically by the Student t-test with α = 0.05. Single Bond (the 5th generation showed a better bond strength compared to the Adper Prompt-L-Pop (the 6th generation.

  18. Microstructure and Mechanical Behavior of High-Entropy Alloys

    Science.gov (United States)

    Licavoli, Joseph J.; Gao, Michael C.; Sears, John S.; Jablonski, Paul D.; Hawk, Jeffrey A.

    2015-10-01

    High-entropy alloys (HEAs) have generated interest in recent years due to their unique positioning within the alloy world. By incorporating a number of elements in high proportion, usually of equal atomic percent, they have high configurational entropy, and thus, they hold the promise of interesting and useful properties such as enhanced strength and alloy stability. The present study investigates the mechanical behavior, fracture characteristics, and microstructure of two single-phase FCC HEAs CoCrFeNi and CoCrFeNiMn with some detailed attention given to melting, homogenization, and thermo-mechanical processing. Ingots approaching 8 kg in mass were made by vacuum induction melting to avoid the extrinsic factors inherent to small-scale laboratory button samples. A computationally based homogenization heat treatment was given to both alloys in order to eliminate any solidification segregation. The alloys were then fabricated in the usual way (forging, followed by hot rolling) with typical thermo-mechanical processing parameters employed. Transmission electron microscopy was subsequently used to assess the single-phase nature of the alloys prior to mechanical testing. Tensile specimens (ASTM E8) were prepared with tensile mechanical properties obtained from room temperature through 800 °C. Material from the gage section of selected tensile specimens was extracted to document room and elevated temperature deformation within the HEAs. Fracture surfaces were also examined to note fracture failure modes. The tensile behavior and selected tensile properties were compared with results in the literature for similar alloys.

  19. Effect of Manufacturing Method to Tensile Properties of Hybrid Composite Reinforced by Natural (Agel Leaf Fiber) and Glass Fibers

    Science.gov (United States)

    Nugroho, A.; Abdurohman, K.; Kusmono; Hestiawan, H.; Jamasri

    2018-04-01

    This paper described the effect of different type of manufacturing method to tensile properties of hybrid composite woven agel leaf fiber and glass fiber as an alternative of LSU structure material. The research was done by using 3 ply of woven agel leaf fiber (ALF) and 3 ply of glass fiber (wr200) while the matrix was using unsaturated polyester. Composite manufacturing method used hand lay-up and vacuum bagging. Tensile test conducted with Tensilon universal testing machine, specimen shape and size according to standard size ASTM D 638. Based on tensile test result showed that the tensile strength of agel leaf fiber composite with unsaturated polyester matrix is 54.5 MPa by hand lay-up and 84.6 MPa with vacuum bagging method. From result of tensile test, hybrid fiber agel composite and glass fiber with unsaturated polyester matrix have potential as LSU structure.

  20. Prediction of Splitting Tensile Strength of Concrete Containing Zeolite and Diatomite by ANN

    Directory of Open Access Journals (Sweden)

    E. Gülbandılar

    2017-01-01

    Full Text Available This study was designed to investigate with two different artificial neural network (ANN prediction model for the behavior of concrete containing zeolite and diatomite. For purpose of constructing this model, 7 different mixes with 63 specimens of the 28, 56 and 90 days splitting tensile strength experimental results of concrete containing zeolite, diatomite, both zeolite and diatomite used in training and testing for ANN systems was gathered from the tests. The data used in the ANN models are arranged in a format of seven input parameters that cover the age of samples, Portland cement, zeolite, diatomite, aggregate, water and hyper plasticizer and an output parameter which is splitting tensile strength of concrete. In the model, the training and testing results have shown that two different ANN systems have strong potential as a feasible tool for predicting 28, 56 and 90 days the splitting tensile strength of concrete containing zeolite and diatomite.

  1. Mechanical Behavior of Red Sandstone under Incremental Uniaxial Cyclical Compressive and Tensile Loading

    Directory of Open Access Journals (Sweden)

    Baoyun Zhao

    2017-01-01

    Full Text Available Uniaxial experiments were carried out on red sandstone specimens to investigate their short-term and creep mechanical behavior under incremental cyclic compressive and tensile loading. First, based on the results of short-term uniaxial incremental cyclic compressive and tensile loading experiments, deformation characteristics and energy dissipation were analyzed. The results show that the stress-strain curve of red sandstone has an obvious memory effect in the compressive and tensile loading stages. The strains at peak stresses and residual strains increase with the cycle number. Energy dissipation, defined as the area of the hysteresis loop in the stress-strain curves, increases nearly in a power function with the cycle number. Creep test of the red sandstone was also conducted. Results show that the creep curve under each compressive or tensile stress level can be divided into decay and steady stages, which cannot be described by the conventional Burgers model. Therefore, an improved Burgers creep model of rock material is constructed through viscoplastic mechanics, which agrees very well with the experimental results and can describe the creep behavior of red sandstone better than the Burgers creep model.

  2. Nylon-6/rubber blends: 6. Notched tensile impact testing of nylon-6(ethylene-propylene rubber) blends

    NARCIS (Netherlands)

    Dijkstra, Krijn; Dijkstra, K.; ter Laak, J.A.; ter Laak, J.; Gaymans, R.J.

    1994-01-01

    The deformation and fracture behaviour of nylon-6/EPR (ethylene-propylene rubber) blends is studied as a function of strain rate and rubber content. Therefore, tensile experiments are conducted on notched specimens over a broad range of draw speeds (including strain rates as encountered in normal

  3. Additive Manufacturing of PLA and CF/PLA Binding Layer Specimens via Fused Deposition Modeling

    Science.gov (United States)

    Li, Yuhang; Gao, Shiyou; Dong, Rongmei; Ding, Xuebing; Duan, Xiaoxi

    2018-02-01

    As one of the most popular additive manufacturing techniques, fused deposition modeling (FDM) is successfully applied in aerospace, automotive, architecture, and other fields to fabricate thermoplastic parts. Unfortunately, as a result of the limited nature of the mechanical properties and mass in raw materials, there is a pressing need to improve mechanical properties and reduce weight for FDM parts. Therefore, this paper presents an experiment of a special polylactic acid (PLA) and carbon fiber (CF)/PLA-laminated experimental specimen fabricated using the FDM process. The mechanical properties and mass analysis of the new composites for the PLA and CF/PLA binding layer specimen are investigated experimentally. Through the experimental analysis, one can conclude that the mass of laminated specimen is lighter than the CF/PLA specimen, and the tensile and flexural mechanical properties are higher than the pure PLA specimen.

  4. Damped button electrode for B-Factory BPM system

    Energy Technology Data Exchange (ETDEWEB)

    Shintake, T; Akasaka, N; Obina, T; Chin, Y H [National Lab. for High Energy Physics, Tsukuba, Ibaraki (Japan)

    1996-08-01

    A new concept of damping of resonances in a button electrode has been proposed and tested in the BPM system for the B-Factory project at KEK (KEKB). Since a very high current beam has to be stored in the machine, even a small resonance in the ring will result in losing a beam due to multi-bunch instabilities. In a conventional button electrode used in BPMs, a TE110 mode resonance can be trapped in the gap between the electrode and the vacuum chamber. In order to damp this mode, the diameter of the electrode has been chosen to be small to increase the resonance frequency and to radiate the power into the beam pipe. In addition, an asymmetric structure is applied to extract the EM energy of the TE110 mode into the coaxial cable as the propagating TEM mode which has no cut-off frequency. Results of the computer simulations and tests with cold models are reported. The quality factor of the TE110 mode was small enough due to the radiation into the beam pipe even in the conventional electrode and the mode coupling effect due to the asymmetric shape was significant on a cavity-like TE111 mode. (author)

  5. Performance of Grouted Splice Sleeve Connector under Tensile Load

    Directory of Open Access Journals (Sweden)

    A. Alias

    2016-05-01

    Full Text Available The grouted splice sleeve connector system takes advantage of the bond-slip resistance of the grout and the mechanical gripping of reinforcement bars to provide resistance to tensile force. In this system, grout acts as a load-transferring medium and bonding material between the bars and sleeve. This study adopted the end-to-end rebars connection method to investigate the effect of development length and sleeve diameter on the bonding performance of the sleeve connector. The end-to-end method refers to the condition where reinforcement bars are inserted into the sleeve from both ends and meet at the centre before grout is filled. Eight specimens of grouted splice sleeve connector were tested under tensile load to determine their performance. The sleeve connector was designed using 5 mm thick circular hollow section (CHS steel pipe and consisted of one external and two internal sleeves. The tensile test results show that connectors with a smaller external and internal sleeve diameter appear to provide better bonding performance. Three types of failure were observed in this research, which are bar fracture (outside the sleeve, bar pullout, and internal sleeve pullout. With reference to these failure types, the development length of 200 mm is the optimum value due to its bar fracture type, which indicates that the tensile capacity of the connector is higher than the reinforcement bar. It is found that the performance of the grouted splice sleeve connector is influenced by the development length of the reinforcement bar and the diameter of the sleeve.

  6. Fracture toughness versus micro-tensile bond strength testing of adhesive-dentin interfaces.

    Science.gov (United States)

    De Munck, Jan; Luehrs, Anne-Katrin; Poitevin, André; Van Ende, Annelies; Van Meerbeek, Bart

    2013-06-01

    To assess interfacial fracture toughness of different adhesive approaches and compare to a standard micro-tensile bond-strength (μTBS) test. Chevron-notched beam fracture toughness (CNB) was measured following a modified ISO 24370 standard. Composite bars with dimensions of 3.0×4.0×25 mm were prepared, with the adhesive-dentin interface in the middle. At the adhesive-dentin interface, a chevron notch was prepared using a 0.15 mm thin diamond blade mounted in a water-cooled diamond saw. Each specimen was loaded until failure in a 4-point bend test setup and the fracture toughness was calculated according to the ISO specifications. Similarly, adhesive-dentin micro-specimens (1.0×1.0×8-10 mm) were stressed in tensile until failure to determine the μTBS. A positive correlation (r(2)=0.64) was observed between CNB and μTBS, which however was only nearly statistically significant, mainly due to the dissimilar outcome of Scotchbond Universal (3M ESPE). While few μTBS specimens failed at the adhesive-dentin interface, almost all CNB specimens failed interfacially at the notch tip. Weibull moduli for interfacial fracture toughness were much higher than for μTBS (3.8-11.5 versus 2.7-4.8, respectively), especially relevant with regard to early failures. Although the ranking of the adhesives on their bonding effectiveness tested using CNB and μTBS corresponded well, the outcome of CNB appeared more reliable and less variable. Fracture toughness measurement is however more laborious and requires specific equipment. The μTBS nevertheless appeared to remain a valid method to assess bonding effectiveness in a versatile way. Copyright © 2013 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.

  7. Dynamic tensile fracture of mortar at ultra-high strain-rates

    International Nuclear Information System (INIS)

    Erzar, B.; Buzaud, E.; Chanal, P.-Y.

    2013-01-01

    During the lifetime of a structure, concrete and mortar may be exposed to highly dynamic loadings, such as impact or explosion. The dynamic fracture at high loading rates needs to be well understood to allow an accurate modeling of this kind of event. In this work, a pulsed-power generator has been employed to conduct spalling tests on mortar samples at strain-rates ranging from 2 × 10 4 to 4 × 10 4  s −1 . The ramp loading allowed identifying the strain-rate anytime during the test. A power law has been proposed to fit properly the rate-sensitivity of tensile strength of this cementitious material over a wide range of strain-rate. Moreover, a specimen has been recovered damaged but unbroken. Micro-computed tomography has been employed to study the characteristics of the damage pattern provoked by the dynamic tensile loading

  8. Strain localization during tensile Hopkinson bar testing of commercially pure titanium and Ti6Al4V titanium alloy

    Directory of Open Access Journals (Sweden)

    Moćko Wojciech

    2015-01-01

    Full Text Available The goal of the analysis was to determine the strain localization for various specimen shapes (type A and type B according to PN-EN ISO 26203-1 standard and different loading conditions, i.e. quasi- static and dynamic. Commercially pure titanium (Grade 2 and titanium alloy Ti6Al4V (Grade 5 were selected for the tests. Tensile loadings were applied out using servo-hydraulic testing machine and tensile Hopkinson bar with pre-tension. The results were recorded using ARAMIS system cameras and fast camera Phantom V1210, respectively at quasi-static and dynamic loading conditions. Further, specimens outline was determined on the basis of video data using TEMA MOTION software. The strain distribution on the specimen surface was estimated using digital image correlation method. The larger radius present in the specimen of type B in comparison to specimen of type A, results in slight increase of the elongation for commercially pure titanium at both quasi-static and dynamic loading conditions. However this effect disappears for Ti6Al4V alloy. The increase of the elongation corresponds to the stronger necking effect. Material softening due to increase of temperature induced by plastic work was observed at dynamic loading conditions. Moreover lower elongation at fracture point was found at high strain rates for both materials.

  9. 49 CFR 178.60 - Specification 8AL steel cylinders with porous fillings for acetylene.

    Science.gov (United States)

    2010-10-01

    ...) Cross-head speed of the testing machine may not exceed 1/8 inch per minute during yield strength... increment of tensile strength above 50,000 psi to a maximum of four such increments. (n) Weld tests...: (1) Tensile test. A specimen must be cut from one cylinder of each lot of 200 or less, or welded test...

  10. Effect of Incorporation of Antifungal Agents on the Ultimate Tensile Strength of Temporary Soft Denture Liners.

    Science.gov (United States)

    Neppelenbroek, Karin Hermana; Lima, Jozely Francisca Mello; Hotta, Juliana; Galitesi, Lucas Lulo; Almeida, Ana Lucia Pompéia Fraga; Urban, Vanessa Migliorini

    2018-02-01

    To investigate the ultimate tensile strength of temporary soft denture liners modified by minimum inhibitory concentrations (MICs) of antifungal agents for Candida albicans biofilm (SC5314) determined in previous microbiological research. Dumbbell-shaped specimens (n = 7) with a central cross-sectional area of 6 × 3 × 33 mm were produced by Softone and Trusoft, without (control) or with incorporation of drugs in powder form at MICs for C. albicans biofilm (per g of material powder): nystatin (0.032 g), chlorhexidine diacetate (0.064 g), ketoconazole (0.128 g), miconazole (0.256 g), and itraconazole (0.256 g). After plasticization, specimens were immersed in distilled water at 37°C for 24 hours, 7 or 14 days, and then tested in tension in a universal testing machine at 40 mm/min. Data of tensile strength (MPa) and elongation percentage (%) were submitted to 3-way ANOVA and Tukey's test (α = 0.05). At the end of 14 days, the tensile strength for both materials was significantly lower in the groups modified by miconazole and itraconazole compared to the other groups (p 0.05). After 7 and 14 days in water, miconazole and itraconazole added into both materials resulted in significantly lower elongation percentages compared to the other antifungal agents and control (p 0.05). The addition of the nystatin, chlorhexidine, and ketoconazole at MICs for C. albicans biofilm resulted in no harmful effects on the tensile strength and elongation percentage of the temporary soft denture liner materials up to 14 days. © 2017 by the American College of Prosthodontists.

  11. Analysis of Button Bit Wear and Performance of Down-The-Hole ...

    African Journals Online (AJOL)

    Michael O. Mensah

    2015-12-02

    Dec 2, 2015 ... revealed that wear of rock drill bit is influenced by rock properties. ... equivalent quartz content and silica content are dominant rock properties affecting wear rate of bit button of DTH drill. ..... Cutting, Drilling and Blasting: Rock.

  12. An Asymptomatic Foreign Body in the Nose in an Eighteen-Year-Old Patient: Button Battery

    Directory of Open Access Journals (Sweden)

    Merih Onal

    2015-01-01

    Full Text Available Foreign bodies lodged in the upper airway are a common occurrence in children. Many unusual foreign bodies in the nose have been reported as foreign bodies like nuts, plastic toy parts, beads, and so forth. Most of these produce minimal morbidity but button batteries due to their early chemical disintegration require early surgical intervention. Here, we report a case of button battery lodged in the nose for several years with a symptom of nasal obstruction and chronic sinusitis.

  13. Enhancing stability of essential oils by microencapsulation for preservation of button mushroom during postharvest

    Science.gov (United States)

    Alikhani-Koupaei, Majid; Mazlumzadeh, Meisam; Sharifani, Mohamadmehdi; Adibian, Mohamad

    2014-01-01

    Fresh button mushrooms (Agaricus bisporus L.) are sensitive to browning, water loss, and microbial attack. The short shelf-life of mushrooms is an impediment to the distribution and marketing of the fresh product. Essential oils outstand as an alternative to chemical preservatives and their use in foods meets the demands of consumers for natural products. To resolve controlled release of oil and increase in antioxidant and antimicrobial activities, the oil was incorporated into microcapsules. Effects of microcapsulated thyme (Thymus vulgaris L.) and rosemary (Rosmarinus officinalis L.) on quality of fresh button mushroom were compared. Physicochemical qualities were evaluated during 15 days of storage at 4 ± 0.5°C. All treatments prevented product weight loss and decrease in polyphenoloxidase and peroxidase activities during storage. Color and firmness, microbiological analysis, and total phenolic content caused the least change. With use of microencapsulated oils, mushrooms were within acceptable limits during 10 days of storage. Microencapsulated rosemary oil produced the highest beneficial effects and has potential to improve quality of button mushrooms and extend shelf-life. PMID:25473510

  14. Tensile properties of quadruple melted Zr-2.5Nb pressure tubes evaluated from pressure tube offcuts

    International Nuclear Information System (INIS)

    Shah, Priti Kotak; Dubey, J.S.; Anantharaman, S.

    2013-12-01

    Rajasthan Atomic Power Station-2 (RAPS-2) is the first Pressurised Heavy Water Reactor (PHWR) in India having quadruple melted Zr-2.5Nb pressure tubes. Front-end and back-end off-cuts of sixteen pressure tubes were selected for studying the mechanical properties in axial and transverse directions of the tube. Tension tests were carried out at room temperature and at 300℃ using miniature tensile test specimens. The report presents the experimental details and discusses the base line tensile property data for the quadruple melted pressure tubes of RAPS-2. This data will be useful for the reactor life management. (author)

  15. A new laser reflectance system capable of measuring changing cross-sectional area of soft tissues during tensile testing.

    Science.gov (United States)

    Pokhai, Gabriel G; Oliver, Michele L; Gordon, Karen D

    2009-09-01

    Determination of the biomechanical properties of soft tissues such as tendons and ligaments is dependent on the accurate measurement of their cross-sectional area (CSA). Measurement methods, which involve contact with the specimen, are problematic because soft tissues are easily deformed. Noncontact measurement methods are preferable in this regard, but may experience difficulty in dealing with the complex cross-sectional shapes and glistening surfaces seen in soft tissues. Additionally, existing CSA measurement systems are separated from the materials testing machine, resulting in the inability to measure CSA during testing. Furthermore, CSA measurements are usually made in a different orientation, and with a different preload, prior to testing. To overcome these problems, a noncontact laser reflectance system (LRS) was developed. Designed to fit in an Instron 8872 servohydraulic test machine, the system measures CSA by orbiting a laser transducer in a circular path around a soft tissue specimen held by tissue clamps. CSA measurements can be conducted before and during tensile testing. The system was validated using machined metallic specimens of various shapes and sizes, as well as different sizes of bovine tendons. The metallic specimens could be measured to within 4% accuracy, and the tendons to within an average error of 4.3%. Statistical analyses showed no significant differences between the measurements of the LRS and those of the casting method, an established measurement technique. The LRS was successfully used to measure the changing CSA of bovine tendons during uniaxial tensile testing. The LRS developed in this work represents a simple, quick, and accurate way of reconstructing complex cross-sectional profiles and calculating cross-sectional areas. In addition, the LRS represents the first system capable of automatically measuring changing CSA of soft tissues during tensile testing, facilitating the calculation of more accurate biomechanical properties.

  16. Correlation of fracture toughness with tensile properties for irradiated 20% cold-worked 316 stainless steel

    International Nuclear Information System (INIS)

    Hamilton, M.L.; Garner, F.A.; Wolfer, W.G.

    1983-08-01

    A correlation has been developed which allows an estimate to be made of the toughness of austenitic alloys using more easily obtained tensile data. Tensile properties measured on 20% cold-worked AISI 316 specimens made from ducts and cladding irradiated in EBR-II were used to predict values for the plane strain fracture toughness according to a model originally developed by Krafft. Some microstructural examination is required to determine a parameter designated as the process zone size. In contrast to the frequently employed Hahn-Rosenfeld model, this model gives results which agree with recent experimental determinations of toughness performed in the transgranular failure regime

  17. Tensile properties of V-Cr-Ti alloys after exposure in hydrogen-containing environments

    International Nuclear Information System (INIS)

    Natesan, K.; Soppet, W.K.

    1998-01-01

    A systematic study has been initiated at Argonne National Laboratory to evaluate the performance of several V-Cr-Ti alloys after exposure to environments containing hydrogen at various partial pressures. The goal is to correlate the chemistry of the exposure environment with hydrogen uptake in the samples and its influence on the microstructure and tensile properties of the alloys. At present, the principal effort has focused on the V-4Cr-4Ti alloy of heat identified as BL-71; however other alloys (V-5Cr-5Ti alloy of heats BL-63, and T87, plus V-4Cr-4Ti alloy from General Atomics [GA]) are also being evaluated. Other variables of interest are the effect of initial grain size on the tensile behavior of the alloys. Experiments conducted on specimens of various V-Cr-Ti alloys exposed to pH 2 levels of 0.01 and 3 x 10 -6 torr showed negligible effect of H 2 on either maximum engineering stress or uniform and total elongation. However, uniform and total elongation decreased substantially when the alloys were exposed to 1.0 torr H 2 pressure. Preliminary data from sequential exposures of the materials to low-pO 2 and several low-pH 2 environments did not reveal an adverse effect on the maximum engineering stress or on uniform and total elongation. Further, tests in H 2 environments on specimens annealed at different temperatures showed that grain-size variation by a factor of ∼2 had little or no effect on tensile properties

  18. Button battery injuries in the pediatric aerodigestive tract.

    Science.gov (United States)

    Ettyreddy, Abhinav R; Georg, Matthew W; Chi, David H; Gaines, Barbara A; Simons, Jeffrey P

    2015-12-01

    Children with a button battery impaction present with nonspecific symptoms that may account for a delay in medical care. We conducted a retrospective study of the clinical presentation, management, and complications associated with button battery ingestion in the pediatric aerodigestive tract and to evaluate the associated long-term morbidity. We reviewed the medical records of 23 patients who were treated for button battery impaction at our tertiary care children's hospital from Jan. 1, 2000, through July 31, 2013. This population was made up of 14 boys and 9 girls, aged 7 days to 12 years (mean: 4 yr). Patients were divided into three groups based on the site of impaction; there were 9 impactions in the esophagus and 7 each in the nasal cavity and stomach. We compiled information on the type and size of each battery, the duration of the impaction, presenting symptoms, treatment, and outcomes. The mean duration of battery impaction was 40.6, 30.7, and 21.0 hours in the esophagus, nasal cavity, and stomach, respectively. We were able to identify the specific type of battery in 13 cases; 11 of these cases (85%) involved a 3-V 20-mm lithium ion battery, including all cases of esophageal impaction in which the type of battery was identified. The most common presenting signs and symptoms were vomiting (n = 7 [30%]), difficulty feeding (n = 5 [22%]), cough (n = 5), and bloody nasal discharge (n = 5); none of the presenting signs and symptoms predicted the severity of the injury or the outcome. The median length of hospital stay was far greater in the esophageal group (12 days) than in the nasal and stomach groups (1 day each; p = 0.006). Battery impaction in the esophagus for more than 15 hours was associated with a significantly longer postoperative hospital stay than impaction for less than 15 hours (p = 0.04). Esophageal complications included strictures (n = 5), perforation (n = 3), and tracheoesophageal fistula formation (n = 2). Clinicians should consider battery

  19. The High Temperature Tensile and Creep Behaviors of High Entropy Superalloy.

    Science.gov (United States)

    Tsao, Te-Kang; Yeh, An-Chou; Kuo, Chen-Ming; Kakehi, Koji; Murakami, Hideyuki; Yeh, Jien-Wei; Jian, Sheng-Rui

    2017-10-04

    This article presents the high temperature tensile and creep behaviors of a novel high entropy alloy (HEA). The microstructure of this HEA resembles that of advanced superalloys with a high entropy FCC matrix and L1 2 ordered precipitates, so it is also named as "high entropy superalloy (HESA)". The tensile yield strengths of HESA surpass those of the reported HEAs from room temperature to elevated temperatures; furthermore, its creep resistance at 982 °C can be compared to those of some Ni-based superalloys. Analysis on experimental results indicate that HESA could be strengthened by the low stacking-fault energy of the matrix, high anti-phase boundary energy of the strengthening precipitate, and thermally stable microstructure. Positive misfit between FCC matrix and precipitate has yielded parallel raft microstructure during creep at 982 °C, and the creep curves of HESA were dominated by tertiary creep behavior. To the best of authors' knowledge, this article is the first to present the elevated temperature tensile creep study on full scale specimens of a high entropy alloy, and the potential of HESA for high temperature structural application is discussed.

  20. Effect of laser welding on the titanium ceramic tensile bond strength

    Directory of Open Access Journals (Sweden)

    Rodrigo Galo

    2011-08-01

    Full Text Available Titanium reacts strongly with elements, mainly oxygen at high temperature. The high temperature of titanium laser welding modifies the surface, and may interfere on the metal-ceramic tensile bond strength. OBJECTIVE: The influence of laser welding on the titanium-ceramic bonding has not yet been established. The purpose of this in vitro study was to analyze the influence of laser welding applied to commercially pure titanium (CpTi substructure on the bond strength of commercial ceramic. The influence of airborne particle abrasion (Al2O3 conditions was also studied. MATERIAL AND METHODS: Forty CpTi cylindrical rods (3 mm x 60 mm were cast and divided into 2 groups: with laser welding (L and without laser welding (WL. Each group was divided in 4 subgroups, according to the size of the particles used in airborne particle abrasion: A - Al2O3 (250 µm; B - Al2O3 (180 µm; C - Al2O3 (110 µm; D - Al2O3 (50 µm. Ceramic rings were fused around the CpTi rods. Specimens were invested and their tensile strength was measured at fracture with a universal testing machine at a crosshead speed of 2.0 mm/min and 200 kgf load cell. Statistical analysis was carried out with analysis of variance and compared using the independent t test (p<0.05. RESULTS: Significant differences were found among all subgroups (p<0.05. The highest and the lowest bond strength means were recorded in subgroups WLC (52.62 MPa and LD (24.02 MPa, respectively. CONCLUSION: Airborne particle abrasion yielded significantly lower bond strength as the Al2O3 particle size decreased. Mechanical retention decreased in the laser-welded specimens, i.e. the metal-ceramic tensile bond strength was lower.

  1. Influence of Cutting Temperature on the Tensile Strength of a Carbon Fiber-Reinforced Polymer

    Directory of Open Access Journals (Sweden)

    Jérémy Delahaigue

    2017-12-01

    Full Text Available Carbon fiber-reinforced plastics (CFRP have seen a significant increase in use over the years thanks to their specific properties. Despite continuous improvements in the production methods of laminated parts, a trimming operation is still necessary to achieve the functional dimensions required by engineering specifications. Laminates made of carbon fibers are very abrasive and cause rapid tool wear, and require high cutting temperatures. This creates damage to the epoxy matrix, whose glass-transition temperature is often recognized to be about 180 °C. This study aims to highlight the influence of the cutting temperature generated by tool wear on the surface finish and mechanical properties obtained from tensile tests. Trimming operations were performed on a quasi-isotropic 24-ply carbon/epoxy laminate, of 3.6 mm thickness, with a 6 flutes diamond-coated (CVD cutter. The test specimens of 6 mm and 12 mm wide were obtained by trimming. The reduced width of the coupons allowed amplification of the effect of defects on the measured properties by increasing the proportion of coupon cross-section occupied by the defects. A new tool and a tool in an advanced state of wear were used to generate different cutting temperatures. Results showed a cutting temperature of 300 °C for the new tool and 475 °C for the worn tool. The analysis revealed that the specimens machined with the new tool have no thermal damage and the cut is clean. The plies oriented at −45° presented the worst surface finish according to the failure mode of the fiber. For the worn tool, the surface was degraded and the matrix was carbonized. After cutting, observations showed a degraded resin spread on the machined surface, which reduced the surface roughness and hid the cutting defects. In support of these observations, the tensile tests showed no variation of the mechanical properties for the 12 mm-wide specimens, but did show a 10% loss in mechanical properties for the 6 mm

  2. Lower complication rate and faster return to sports in patients with acute syndesmotic rupture treated with a new knotless suture button device.

    Science.gov (United States)

    Colcuc, Christian; Blank, Marc; Stein, Thomas; Raimann, Florian; Weber-Spickschen, Sanjay; Fischer, Sebastian; Hoffmann, Reinhard

    2017-12-09

    Suture button devices for tibiofibular syndesmosis injuries provide semirigid dynamic stabilization, but complications including knot irritation have been reported. No randomized trials of the new knotless suture button devices have been performed. We hypothesized that knotless suture button devices eliminate knot irritation and facilitate quicker return to sports. This study was performed to compare the clinical outcomes, complication rates, and time to return to sports between a new knotless suture button device and syndesmotic screw fixation. This study included 54 patients treated for ankle syndesmotic injury from 2012 to 2014 with a knotless suture button device or syndesmotic screw fixation. Clinical outcomes were measured using the American Orthopaedics Foot and Ankle Society score, Foot and Ankle Disability Index, Olerud and Molander score, and visual analog scale for pain and function. Secondary outcome measures were the complication rate and time required to return to sports. Patients underwent clinical and radiological evaluations preoperatively and three times during the 1-year postoperative follow-up. 54 of 62 eligible patients were analyzed, median age 37 (18-60) and underwent the 1-year follow-up. The screw fixation and knotless suture button groups comprised 26 and 28 patients, respectively. The complication rate was significantly lower (p = 0.03) and time to return to sports was significantly shorter in the knotless suture button than screw fixation group (average, 14 versus 19 weeks, respectively; p = 0.006). No significant differences were identified in clinical outcomes or visual analog scale scores for pain and function between the groups. Age, injury mechanism, and body mass index did not significantly affect the time required to return to sports activities. The type of fixation was the only independent variable that reached statistical significance (p = 0.006). Syndesmotic screw fixation and the new knotless suture button device

  3. Modified Labial Button Technique for Maintaining Occlusion After Caudal Mandibular Fracture/Temporomandibular Joint Luxation in the Cat.

    Science.gov (United States)

    Goodman, Alice E; Carmichael, Daniel T

    2016-03-01

    Maxillofacial trauma in cats often results in mandibular symphyseal separation in addition to injuries of the caudal mandible and/or temporomandibular joint (TMJ). Caudal mandibular and TMJ injuries are difficult to access and stabilize using direct fixation techniques, thus indirect fixation is commonly employed. The immediate goals of fixation include stabilization for return to normal occlusion and function with the long-term objective of bony union. Indirect fixation techniques commonly used for stabilization of caudal mandibular and temporomandibular joint fracture/luxation include maxillomandibular fixation (MMF) with acrylic composite, interarcade wiring, tape muzzles, and the bignathic encircling and retaining device (BEARD) technique. This article introduces a modification of the previously described "labial reverse suture through buttons" technique used by Koestlin et al and the "labial locking with buttons" technique by Rocha et al. In cases with minimally displaced subcondylar and pericondylar fractures without joint involvement, the labial button technique can provide sufficient stabilization for healing. Advantages of the modified labial button technique include ease of application, noninvasive nature, and use of readily available materials. The construct can remain in place for a variable of amount of time, depending on its intended purpose. It serves as an alternative to the tape muzzle, which is rarely tolerated by cats. This technique can be easily used in conjunction with other maxillomandibular repairs, such as cerclage wire fixation of mandibular symphyseal separation. The purpose of this article is to demonstrate a modified labial button technique for maintaining occlusion of feline caudal mandibular fractures/TMJ luxations in a step-by-step fashion.

  4. Size Effect Studies on Tensile Tests for Hot Stamping Steel

    Science.gov (United States)

    Chen, Xiaodu; Li, Yuanyuan; Han, Xianhong; Zhang, Junbo

    2018-02-01

    Tensile tests have been widely used to determine basic mechanical properties of materials. However, the properties measured may be related to geometrical factors of the tested samples especially for high-strength steels; this makes the properties' definitions and comparisons difficult. In this study, a series of tensile tests of ultra-high-strength hot-stamped steel were performed; the geometric shapes and sizes as well as the cutting direction were modified. The results demonstrate that the hot-stamped parts were isotropic and the cutting direction had no effect; the measured strengths were practically unrelated to the specimen geometries, including both size and shape. The elongations were slightly related to sample sizes within the studied range but highly depended on the sample shape, represented by the coefficient K. Such phenomena were analyzed and discussed based on microstructural observations and fracture morphologies. Moreover, two widely used elongation conversion equations, the Oliver formula and Barba's law, were introduced to verify their applicability, and a new interpolating function was developed and compared.

  5. Tensile and bending fatigue of the adhesive interface to dentin.

    Science.gov (United States)

    Belli, Renan; Baratieri, Luiz Narciso; Braem, Marc; Petschelt, Anselm; Lohbauer, Ulrich

    2010-12-01

    The aim of this study was to evaluate the fatigue limits of the dentin-composite interfaces established either with an etch-and-rinse or an one-step self-etch adhesive systems under tensile and bending configurations. Flat specimens (1.2 mm×5 mm×35 mm) were prepared using a plexiglass mold where dentin sections from human third molars were bonded to a resin composite, exhibiting the interface centrally located. Syntac Classic and G-Bond were used as adhesives and applied according to the manufacturer's instructions. The fluorochrome Rhodamine B was added to the adhesives to allow for fractographic evaluation. Tensile strength was measured in an universal testing machine and the bending strength (n=15) in a Flex machine (Flex, University of Antwerp, Belgium), respectively. Tensile (TFL) and bending fatigue limits (BFL) (n=25) were determined under wet conditions for 10(4) cycles following a staircase approach. Interface morphology and fracture mechanisms were observed using light, confocal laser scanning and scanning electron microscopy. Statistical analysis was performed using three-way ANOVA (mod LSD test, pTensile and bending characteristic strengths at 63.2% failure probability for Syntac were 23.8 MPa and 71.5 MPa, and 24.7 MPa and 72.3 MPa for G-Bond, respectively. Regarding the applied methods, no significant differences were detected between adhesives. However, fatigue limits for G-Bond (TFL=5.9 MPa; BFL=36.2 MPa) were significantly reduced when compared to Syntac (TFL=12.6 MPa; BFL=49.7 MPa). Fracture modes of Syntac were generally of adhesive nature, between the adhesive resin and dentin, while G-Bond showed fracture planes involving the adhesive-dentin interface and the adhesive resin. Cyclic loading under tensile and bending configurations led to a significant strength degradation, with a more pronounced fatigue limit decrease for G-Bond. The greater decrease in fracture strength was observed in the tensile configuration. Copyright © 2010 Academy of

  6. The study on the threshold strain of microvoid formation in TRIP steels during tensile deformation

    International Nuclear Information System (INIS)

    Wang Wurong; Guo Bimeng; Ji Yurong; He Changwei; Wei Xicheng

    2012-01-01

    Highlights: ► The tensile mechanical behaviors of TRIP steels were studied under high rate deformation conditions. ► The threshold strain of microvoid formation was examined quantitatively. ► The effects of retained austenite of TRIP on suppressing microvoid formed during tensile process have been discussed. - Abstract: Transformation Induced Plasticity (TRIP) steels exhibit a better combination of strength and ductility properties than conventional high strength low alloy (HSLA) steels, and therefore receive considerable attention in the automotive industry. In this work, the tensile mechanical behaviors of TRIP-aided steels were studied under the condition of the quasi-static and high deformed rates. The deformed specimens were observed by scanning electron microscope (SEM) along the tensile axis. The threshold strain of microvoid formation was examined quantitatively according to the evolution of deformation. The results showed that: the yield and tensile strengths of TRIP steels increase with the strain rate, whereas their elongations decrease. However, the threshold strain for TRIP steels at high strain rate is larger than that at low strain rate. Comparing with the deformed microstructure and microvoids formed in the necking zone of dual phase (DP) steel, the progressive deformation-induced transformation of retained austenite in TRIP steels remarkably increases the threshold strain of microvoid formation and furthermore postpones its growth and coalescence.

  7. Effects of cavity surface temperature on mechanical properties of specimens with and without a weld line in rapid heat cycle molding

    International Nuclear Information System (INIS)

    Wang, Guilong; Zhao, Guoqun; Wang, Xiaoxin

    2013-01-01

    Highlights: ► Higher cavity surface temperature reduces tensile strength of non-weldline part. ► Higher cavity surface temperature increases weldline tensile strength for PS and PP. ► Higher cavity surface temperature reduces weldline tensile strength for ABS, ABS/PMMA, ABS/PMMA/nano-C a CO 3 and FRPP. ► Tensile strength is reduced more by the weldline than impact strength. ► FRPP has the lowest weld line factor than other plastics without reinforced fibers. - Abstract: Rapid heat cycle molding (RHCM) is a recently developed injection molding technology to enhance surface esthetic of the parts. By rapid heating and cooling of mold cavity surfaces in molding process, it can greatly alleviate or even eliminate the surface defects such as flow mark, weld line, glass fiber rich surface, silver mark, jetting mark, and swirl mark, and also improve gloss finish and dimensional accuracy without prolonging the molding cycle. Besides surface esthetic, mechanical property is also a very import issue for the molded plastic part. The aim of this study is focusing on the effects of the cavity surface temperature just before filling, T cs , in RHCM on the mechanical strength of the specimen with and without weld line. Six kinds of typical plastics including polystyrene (PS), polypropylene (PP), acrylonitrile butadiene styrene (ABS), acrylonitrile butadiene styrene/polymethylmethacrylate (ABS/PMMA), ABS/PMMA/nano-C a CO 3 and glass fiber reinforced polypropylene (FRPP) are used in experiments. The specimens with and without a weld line are produced with the different T cs on the developed electric-heating RHCM system. Tensile tests and notched Izod impact tests are conducted to characterize the mechanical strength of the specimens molded with different cavity surface temperatures. Simulations, differential scanning calorimetry (DSC), scanning electron microscope (SEM) and optical microscope are implemented to explain the impact mechanism of T cs on mechanical properties

  8. Post-uniform elongation and tensile fracture mechanisms of Fe-18Mn-0.6C-xAl twinning-induced plasticity steels

    International Nuclear Information System (INIS)

    Yu, Ha-Young; Lee, Sang-Min; Nam, Jae-Hoon; Lee, Seung-Joon; Fabrègue, Damien; Park, Myeong-heom; Tsuji, Nobuhiro; Lee, Young-Kook

    2017-01-01

    The objective of the present study was to elucidate the complicated interrelationship between necking, post-uniform elongation (e_p_u), strain rate sensitivity (SRS), fracture mechanism and Al concentration in Fe-18Mn-0.6C-xAl twinning-induced plasticity steels. Many tensile tests were conducted for in- and ex-situ observations of necking, fracture surfaces, crack propagation and the density and size of micro-voids with the assistance of a high-speed camera and X-ray tomographic equipment. The addition of Al increased e_p_u, SRS and reduction ratios in dimension of the neck part of tensile specimens, and also changed fracture mode from quasi-cleavage to ductile fracture at the edge part. The quasi-cleavage surface of Al-free specimen was induced by edge and side cracks occurring along grain boundary junctions and twin boundaries within the edges and side surfaces where local deformation bands meet. The ductile-fracture surface of 1.5 %Al-added specimen was formed by the coalescence of micro-voids. While the side-to-middle crack propagation occurred in Al-free and 1 %Al-added specimens due to side cracks, the middle-to-side crack propagation was observed in 1.5 %Al-added specimen. The Al-free specimen had the larger size of the 20 largest voids compared to the 1.5 %Al-added specimen despite its lower void density and local strain due to the accelerated growth of voids near the tips of side cracks. Evaluating the negligible e_p_u of Al-free specimen by SRS is not deemed to be reasonable due to its inappreciable necking and side cracks. The improvement of e_p_u in 1.5 %Al-added specimen is primarily due to disappearance of edge and side cracks.

  9. Tensile properties of vanadium alloys irradiated at 390{degrees}C in EBR-II

    Energy Technology Data Exchange (ETDEWEB)

    Chung, H.M.; Tsai, H.C.; Nowicki, L.J. [Argonne National Lab., IL (United States)] [and others

    1997-08-01

    Vanadium alloys were irradiated in Li-bonded stainless steel capsules to {approx}390{degrees}C in the EBR-II X-530 experiment. This report presents results of postirradiation tests of tensile properties of two large-scale (100 and 500 kg) heats of V-4Cr-Ti and laboratory (15-30 kg) heats of boron-doped V-4Cr-4Ti, V-8Cr-6Ti, V-5Ti, and V-3Ti-1Si alloys. Tensile specimens, divided into two groups, were irradiated in two different capsules under nominally similar conditions. The 500-kg heat (No. 832665) and the 100-kg heat (VX-8) of V-4Cr-4Ti irradiated in one of the subcapsules exhibited complete loss of work-hardening capability, which was manifested by very low uniform plastic strain. In contrast, the 100-kg heat of V-4Cr-4Ti irradiated in another subcapsule exhibited good tensile properties (uniform plastic strain 2.8-4.0%). A laboratory heat of V-3Ti-1Si irradiated in the latter subcapsule also exhibited good tensile properties. These results indicate that work-hardening capability at low irradiation temperatures varies significantly from heat to heat and is influenced by nominally small differences in irradiation conditions.

  10. Thermo-mechanical Fatigue Failure of Thermal Barrier Coated Superalloy Specimen

    Science.gov (United States)

    Subramanian, Rajivgandhi; Mori, Yuzuru; Yamagishi, Satoshi; Okazaki, Masakazu

    2015-09-01

    Failure behavior of thermal barrier coated (TBC) Ni-based superalloy specimens were studied from the aspect of the effect of bond coat material behavior on low cycle fatigue (LCF) and thermo-mechanical fatigue (TMF) at various temperatures and under various loading conditions. Initially, monotonic tensile tests were carried out on a MCrAlY alloy bond coat material in the temperature range of 298 K to 1273 K (25 °C to 1000 °C). Special attention was paid to understand the ductile to brittle transition temperature (DBTT). Next, LCF and TMF tests were carried out on the thermal barrier coated Ni-based alloy IN738 specimen. After these tests, the specimens were sectioned to understand their failure mechanisms on the basis of DBTT of the bond coat material. Experimental results demonstrated that the LCF and TMF lives of the TBC specimen were closely related to the DBTT of the bond coat material, and also the TMF lives were different from those of LCF tests. It has also been observed that the crack density in the bond coat in the TBC specimen was significantly dependent on the test conditions. More importantly, not only the number of cracks but also the crack penetration probability into substrate were shown to be sensitive to the DBTT.

  11. Tensile strength of cementing agents on the CeraOne system of dental prosthesis on implants.

    Science.gov (United States)

    Montenegro, Alexandre Campos; Machado, Aldir Nascimento; Depes Gouvêa, Cresus Vinicius

    2008-12-01

    The aim of this in vitro study was to evaluate the tensile strength of titanium cylinders cemented on stainless steel abutment mock-ups by the Cerazone system. Four types of cements were used: glass ionomer, Fuji I (GC); zinc phosphate, Cimento LS (Vigodent); zinc oxide without eugenol, Rely x Temp NE (3M ESPE); and resin cement, Rely x ARC (3M ESPE). Four experimental groups were formed, each composed of 5 test specimens. Each test specimen consisted of a set of 1 cylinder and 1 stainless steel abutment mock-up. All cements tested were manipulated in accordance with manufacturers' instructions. A static load of 5 Newtons (N) for 2 minutes was used to standardize the procedure. The tensile tests were performed by a mechanical universal testing machine (EMIC DL500MF) at a crosshead speed of 0.5 mm/min. The highest bonding values resulting from the experiment were obtained by Cimento LS (21.86 MPa mean), followed by the resin cement Rely x ARC (12.95 MPa mean), Fuji I (6.89 MPa mean), and Rely x Temp NE (4.71 MPa mean). The results were subjected to analysis of variance (ANOVA) and the Student's t test. The cements differed amongst them as regards tensile strength, with the highest bonding levels recorded with zinc phosphate (Cimento LS) and the lowest with the zinc oxide without eugenol (Rely x Temp NE).

  12. Effects of low doses of 14-MeV neutrons on the tensile properties of three binary copper alloys

    International Nuclear Information System (INIS)

    Heinisch, H.L.; Pintler, J.S.

    1986-12-01

    Miniature tensile specimens of high purity copper and copper alloyed respectively with five atom percent of Al, Mn, and Ni were irradiated with D-T fusion neutrons in the RTNS-II to fluences up to 1.3 x 10 18 n/cm 2 at 90 0 C. To compare fission and fusion neutron effects, some specimens were also irradiated at the same temperature to similar damage levels in the Omega West Reactor (OWR). Tensile tests were performed at room temperature, and the radiation-induced changes in tensile properties were examined as functions of displacements per atom (dpa). The irradiation-induced strengthening of Cu5%Mn is greater than that of Cu5%Al and Cu5%Ni, which behave about the same. However, all the alloys sustain less irradiation-induced strengthening by 14 MeV neutrons than pure copper, which is in contrast to the reported results of earlier work using hardness measurements. The effects of fission and fusion neutrons on the yield stress of Cu5%Al and Cu5%Ni correlate well on the basis of dpa, but the data for Cu5%Mn suggest that dpa may not be a good correlation parameter for this alloy in this fluence and temperature range

  13. Combined spectrophotometry and tensile measurements of human connective tissues: potentials and limitations.

    Science.gov (United States)

    Ernstberger, Markus; Sichting, Freddy; Baselt, Tobias; Hartmann, Peter; Aust, Gabriela; Hammer, Niels

    2013-06-01

    Strain-dependent transmission data of nine iliotibial tract specimens are determined using a custom-built optical setup with a halogen light source and an industrial norm material testing machine. Polarized light microscopy and hematoxylin-eosin staining indicated that lateral contraction of collagen structures is responsible for total intensity variations during a 20-cycle preconditioning and a 5-cycle tensile test. Tensile force progress is opposite to total transmission progress. Due to dehydration, wavelength-specific radiation intensity shifting is determined during the test, primarily noticeable in a water absorption band between 1400 and 1500 nm. The results show the capability of integrating spectrophotometry technology into biomechanics for determining structural alterations of human collagen due to applied strain. Being more sensitive to drying, spectrophotometry may likely serve as a quality control in stress-strain testing of biological structures.

  14. Dynamic strain aging of twinning-induced plasticity (TWIP) steel in tensile testing and deep drawing

    International Nuclear Information System (INIS)

    Kim, J.G.; Hong, S.; Anjabin, N.; Park, B.H.; Kim, S.K.; Chin, K.-G.; Lee, S.; Kim, H.S.

    2015-01-01

    The dynamic strain aging (DSA) of metallic materials due to solute atom diffusion to mobile dislocations induce deformation instability with load fluctuations and deformation localizations, hence reducing their sheet formability. In this paper, DSA behaviors of twinning induced plasticity (TWIP) steel with and without Al during tensile testing and deep drawing are investigated in terms of strain localization and the Portevin-Le Chatelier (PLC) band. A theoretical DSA model with internal variables of dislocation density and twin volume fraction is presented for an estimation of strain localization and strain hardening behavior of TWIP steels. The simulation results of the load history and PLC bands during tensile testing and deep drawing are in good agreement with the experimental values. A serration behavior is observed in high-Mn TWIP steels and its tensile residual stress is higher than that in the Al-added TWIP steels, which results in a deformation crack or delayed fracture of deep drawn specimens

  15. The elevated temperature tensile properties of S-200E commercially pure beryllium

    International Nuclear Information System (INIS)

    Henshall, G.A.; Torres, S.G.; Hanafee, J.E.

    1995-01-01

    The tensile properties of commercially pure beryllium are sensitive to temperature, impurity content, texture, grain size, and prior processing. Therefore, tensile tests have been conducted using the commercially pure S-200E Be commonly employed at Lawrence Livermore National Laboratory. These experiments were performed at temperatures ranging from 300 to 1100 degrees C in the longitudinal and transverse orientations at the quasi-static strain rate of 5.5 x 10 -4 s -1 . The results of these experiments reveal that the stress-strain curve is smooth, ie. without yield points or serrations, over the entire temperature range studied. The yield stress (YS) and ultimate tensile stress (UTS) decrease monotonically with increasing temperature. Similar strengths were measured for both the longitudinal and transverse orientations, with the latter exhibiting slightly lower YS and UTS values. The measured failure elongation (e f ) vs. temperature curve is complex due to the competing effects of increasing basal-plane fracture stress with increasing temperature combined with the presence of hot shortness at intermediate temperatures. The latter is believed to be caused, at least partially, by the presence of free aluminum impurities at the grain boundaries. This hypothesis is supported by the measured increase in e f at 700 degrees C following a 100-hr anneal at 750 degrees C, which would remove free Al from the grain boundaries. Texture also was found to influence e f . The favorable orientation of the basal planes for initiation and propagation of cleavage cracks in longitudinal specimens results in a significantly decreased failure elongation compared with the transverse orientation. The effects of testing temperature and specimen orientation on the reduction in area were found to be similar to those described for e f

  16. Twinning and martensitic transformations in nickel-enriched 304 austenitic steel during tensile and indentation deformations

    Energy Technology Data Exchange (ETDEWEB)

    Gussev, M.N., E-mail: gussevmn@ornl.gov; Busby, J.T.; Byun, T.S.; Parish, C.M.

    2013-12-20

    Twinning and martensitic transformation have been investigated in nickel-enriched AISI 304 stainless steel subjected to tensile and indentation deformation. Using electron backscatter diffraction (EBSD), the morphology of α- and ε-martensite and the effect of grain orientation to load axis on phase and structure transformations were analyzed in detail. It was found that the twinning occurred less frequently under indentation than under tension; also, twinning was not observed in [001] and [101] grains. In tensile tests, the martensite particles preferably formed at the deformation twins, intersections between twins, or at the twin-grain boundary intersections. Conversely, martensite formation in the indentation tests was not closely associated with twinning; instead, the majority of martensite was concentrated in the dense colonies near grain boundaries. Martensitic transformation seemed to be obstructed in the [001] grains in both tensile and indentation test cases. Under a tensile stress of 800 MPa, both α- and ε-martensites were found in the microstructure, but at 1100 MPa only α-martensite presented in the specimen. Under indentation, α- and ε-martensite were observed in the material regardless of the stress level.

  17. Microstructural evolution and tensile properties of Sn-Ag-Cu mixed with Sn-Pb solder alloys

    Energy Technology Data Exchange (ETDEWEB)

    Wang Fengjiang [Department of Materials Science and Engineering and Materials Research Center, Missouri University of Science and Technology, Rolla, MO 65401 (United States); O' Keefe, Matthew [Department of Materials Science and Engineering and Materials Research Center, Missouri University of Science and Technology, Rolla, MO 65401 (United States)], E-mail: mjokeefe@mst.edu; Brinkmeyer, Brandon [Department of Materials Science and Engineering and Materials Research Center, Missouri University of Science and Technology, Rolla, MO 65401 (United States)

    2009-05-27

    The effect of incorporating eutectic Sn-Pb solder with Sn-3.0Ag-0.5Cu (SAC) Pb-free solder on the microstructure and tensile properties of the mixed alloys was investigated. Alloys containing 100, 75, 50, 25, 20, 15, 10, 5 and 0 wt% SAC, with the balance being Sn-37Pb eutectic solder alloy, were prepared and characterized. Optical and scanning electron microscopy were used to analyze the microstructures while 'mini-tensile' test specimens were fabricated and tested to determine mechanical properties at the mm length scale, more closely matching that of the solder joints. Microstructural analysis indicated that a Pb-rich phase formed and was uniformly distributed at the boundary between the Sn-rich grains or between the Sn-rich and the intermetallic compounds in the solder. Tensile results showed that mixing of the alloys resulted in an increase in both the yield and the ultimate tensile strength compared to the original solders, with the 50% SAC-50% Sn-Pb mixture having the highest measured strength. Initial investigations indicate the formation and distribution of a Pb-rich phase in the mixed solder alloys as the source of the strengthening mechanism.

  18. Button sequestrum in a case of localized Langerhans' cell histiocytosis of the ilium: case report

    International Nuclear Information System (INIS)

    Tordeur, M.; Wybier, M.; Laporte, J.L.; Grenier, P.; Laredo, J.D.

    2000-01-01

    Langerhans' cell histiocytosis (LCH) is characterized by a proliferation of cells exhibiting the same immunohistochemical and ultra-structural characteristics as Langerhans' cells of the epidermis. Eosinophilic granuloma, chronic polyostotic disease (Hand-Schuller-Christian disease) and multisystemic disease (Letterer-Siwe disease) all belong to the spectrum LCH. Osseous lesions are the most common findings. the radiological appearance of skeletal LCH depends on the site and on disease activity. Button sequestrum has been described as uncommon in LCH of the skull and exceedingly rare in LCH at other sites. We report a case of localized LCH of the ilium with a button sequestrum. (author)

  19. Analysis of tensile and fracture toughness results on irradiated molybdenum alloys, TZM and Mo-5%Re. Analysis of results performed in the frame of the NET task PDS 1.4

    Energy Technology Data Exchange (ETDEWEB)

    Scibetta, M.; Chaouadi, R.; Puzzolante, J.L

    1999-10-01

    Due to their good resistance at high temperature, good thermal conductivity and swelling resistance, molybdenum alloys are considered amongst the candidates for divertor structural materials. However, little is known about their tensile and fracture toughness behaviour, in particular after irradiation. This report aims to investigate the tensile and fracture toughness properties of two molybdenum alloys, namely TZM and Mo-5%Re. Tensile and compact tension specimens were irradiated in the BR2 reactor at 40 and 450 degrees Celsius up to a fast neutron fluence of 3.5 1020 n/cm{sup 2} (0.2 dpa). Fracture toughness tests were performed on both precracked and notched specimens. Results show a drastic decrease of the ductility due to irradiation, but only a slight decrease of the fracture toughness in the lower shelf domain.

  20. Analysis of tensile and fracture toughness results on irradiated molybdenum alloys, TZM and Mo-5%Re. Analysis of results performed in the frame of the NET task PDS 1.4

    International Nuclear Information System (INIS)

    Scibetta, M.; Chaouadi, R.; Puzzolante, J.L.

    1999-10-01

    Due to their good resistance at high temperature, good thermal conductivity and swelling resistance, molybdenum alloys are considered amongst the candidates for divertor structural materials. However, little is known about their tensile and fracture toughness behaviour, in particular after irradiation. This report aims to investigate the tensile and fracture toughness properties of two molybdenum alloys, namely TZM and Mo-5%Re. Tensile and compact tension specimens were irradiated in the BR2 reactor at 40 and 450 degrees Celsius up to a fast neutron fluence of 3.5 1020 n/cm 2 (0.2 dpa). Fracture toughness tests were performed on both precracked and notched specimens. Results show a drastic decrease of the ductility due to irradiation, but only a slight decrease of the fracture toughness in the lower shelf domain

  1. Effect of tensile stress on the annealed structure of a metallic glass

    International Nuclear Information System (INIS)

    Vianco, P.T.; Li, J.C.M.

    1987-01-01

    The low-temperature (120 0 --245 0 C) structural relaxation of Metglas/sup R/ 2826B (Ni 49 Fe 29 P 14 B 6 Si 2 ) amorphous alloy was investigated for samples subjected to a tensile stress in the range of 20--400 MPa during annealing. The stress-annealed samples demonstrated a much smaller increase of microhardness than was observed in similarly annealed ribbons without a stress. Further heat treatment of the stress-annealed specimens, this time without the stress, was capable of increasing the microhardnesses of only some ribbons to values equal to those of samples similarly heat treated initially without a stress. An additional exothermic peak in the differential scanning calorimetry (DSC) thermograms of the stress-annealed specimens indicated the presence of a more disordered structure at room temperature, which was found to correlate with the lower microhardness values. Otherwise, those artifacts of the DSC thermograms that were characteristic of samples annealed without a stress were still present in the stress-annealed ribbons. No effect on the crystallization temperature was noted but the glass transition temperature was increased in the stress-annealed case with respect to values attained when the stress was absent during heat treatment. A reduction in the degree of embrittlement of those samples annealed with a tensile stress was a further indication of more disorder in the stress-annealed ribbons

  2. Utility of eButton images for identifying food preparation behaviors and meal-related tasks in adolescents.

    Science.gov (United States)

    Raber, Margaret; Patterson, Monika; Jia, Wenyan; Sun, Mingui; Baranowski, Tom

    2018-02-24

    Food preparation skills may encourage healthy eating. Traditional assessment of child food preparation employs self- or parent proxy-reporting methods, which are prone to error. The eButton is a wearable all-day camera that has promise as an objective, passive method for measuring child food preparation practices. This paper explores the feasibility of the eButton to reliably capture home food preparation behaviors and practices in a sample of pre- and early adolescents (ages 9 to 13). This is a secondary analysis of two eButton pilot projects evaluating the dietary intake of pre- and early adolescents in or around Houston, Texas. Food preparation behaviors were coded into seven major categories including: browsing, altering food/adding seasoning, food media, meal related tasks, prep work, cooking and observing. Inter-coder reliability was measured using Cohen's kappa and percent agreement. Analysis was completed on data for 31 participants. The most common activity was browsing in the pantry or fridge. Few participants demonstrated any food preparation work beyond unwrapping of food packages and combining two or more ingredients; actual cutting or measuring of foods were rare. Although previous research suggests children who "help" prepare meals may obtain some dietary benefit, accurate assessment tools of food preparation behavior are lacking. The eButton offers a feasible approach to food preparation behavior measurement among pre- and early adolescents. Follow up research exploring the validity of this method in a larger sample, and comparisons between cooking behavior and dietary intake are needed.

  3. Effect of helium and DPA's on tensile properties of V-5Ti and V-3Ti-1Si

    International Nuclear Information System (INIS)

    Witzenburg, W. van; Vries, E. de.

    1991-02-01

    Specimens of the alloys V-5Ti and V-3Ti-1Si were irradiated in a mixed-spectrum fission reactor in reactor grade liquid sodium to a fast neutron fluence of 3.8 x 10 25 m -2 (E>0.1 MeV), which corresponds to 6.2 dpa. Irradiation temperatures were 500, 600 and 700 deg C. Some of the specimens were pre-injected with helium to 100 appm at approx 50 deg C by means of a cyclotron. In addition, part of the specimens were doped with boron-10 to concentrations of 100 and 600 appm. Tensile testing, at temperatures equal to the irradiation temperatures and at a strain rate of 10 -4 s -1 , showed an increase in strength and reduced elongation at 500 deg C and to a lesser extent at 600 deg C. These changes are caused by displacement damage. Helium, pre-injected as well as produced by transmutation of boron-10, did not have a significant influence on the tensile properties. Cavities seen in the irradiated materials at low concentrations, were not preferentially located on grain boundaries. There was no apparent deleterious effect of lithium, which is also a transmutation product of boron-10. (author). 12 refs.; 8 figs.; 3 tabs

  4. Experimental and Numerical Evaluation of Direct Tension Test for Cylindrical Concrete Specimens

    Directory of Open Access Journals (Sweden)

    Jung J. Kim

    2014-01-01

    Full Text Available Concrete cracking strength can be defined as the tensile strength of concrete subjected to pure tension stress. However, as it is difficult to apply direct tension load to concrete specimens, concrete cracking is usually quantified by the modulus of rupture for flexural members. In this study, a new direct tension test setup for cylindrical specimens (101.6 mm in diameter and 203.2 mm in height similar to those used in compression test is developed. Double steel plates are used to obtain uniform stress distributions. Finite element analysis for the proposed test setup is conducted. The uniformity of the stress distribution along the cylindrical specimen is examined and compared with rectangular cross section. Fuzzy image pattern recognition method is used to assess stress uniformity along the specimen. Moreover, the probability of cracking at different locations along the specimen is evaluated using probabilistic finite element analysis. The experimental and numerical results of the cracking location showed that gravity effect on fresh concrete during setting time might affect the distribution of concrete cracking strength along the height of the structural elements.

  5. An Electron Microscope Study of the Thermal Neutron Induced Loss in High Temperature Tensile Ductility of Nb Stabilized Austenitic Steels

    International Nuclear Information System (INIS)

    Roy, R.B.

    1965-04-01

    Irradiated ∼3 x 10 19 n/cm 2 (thermal), 18 n/cm 2 (> 1 MeV) at 40 deg C and the corresponding unirradiated control tensile specimens of a 20 % Cr, 25 % Ni, Nb stabilized steel tested at 650 deg C, 750 deg C and 800 deg C have been examined by transmission electron microscopy. The results indicate that the irradiation induced embrittlement of the tensile specimens at elevated temperatures is preceded by the formation of fine precipitates within the grains. These precipitates may restrict the deformation within the grains such that the stresses are concentrated at the grain boundaries thereby leading to premature failure. It is suggested that the main effect of the irradiation is to promote conditions necessary for the formation of these precipitates, namely, super saturation and fresh nucleation sites within the matrix through the energetic emission of He and Li atoms from boron as an impurity

  6. Effect of cryogenic treatment on tensile behavior of case carburized steel-815M17

    International Nuclear Information System (INIS)

    Bensely, A.; Senthilkumar, D.; Mohan Lal, D.; Nagarajan, G.; Rajadurai, A.

    2007-01-01

    The crown wheel and pinion represent the most highly stressed parts of a heavy vehicle; these are typically made of 815M17 steel. The reasons for the frequent failure of these components are due to tooth bending impact, wear and fatigue. The modern processes employed to produce these as high, durable components include cryogenic treatment as well as conventional heat treatment. It helps to convert retained austenite into martensite as well as promote carbide precipitation. This paper deals with the influence of cryogenic treatment on the tensile behavior of case carburized steel 815M17. The impetus for studying the tensile properties of gear steels is to ensure that steels used in gears have sufficient tensile strength to prevent failure when gears are subjected to tensile or fatigue loads, and to provide basic design information on the strength of 815M17 steel. A comparative study on the effects of deep cryogenic treatment (DCT), shallow cryogenic treatment (SCT) and conventional heat treatment (CHT) was made by means of tension testing. This test was conducted as per ASTM standard designation E 8M. The present results confirm that the tensile behavior is marginally reduced after cryogenic treatment (i.e. both shallow and deep cryogenic treatment) for 815M17 when compared with conventional heat treatment. Scanning electron microscopic (SEM) analysis of the fracture surface indicates the presence of dimples and flat fracture regions are more common in SCT specimens than for CHT and DCT-processed material

  7. Rupture tests with reactor pressure vessel head models

    International Nuclear Information System (INIS)

    Talja, H.; Keinaenen, H.; Hosio, E.; Pankakoski, P.H.; Rahka, K.

    2003-01-01

    In the LISSAC project (LImit Strains in Severe ACcidents), partly funded by the EC Nuclear Fission and Safety Programme within the 5th Framework programme, an extensive experimental and computational research programme is conducted to study the stress state and size dependence of ultimate failure strains. The results are aimed especially to make the assessment of severe accident cases more realistic. For the experiments in the LISSAC project a block of material of the German Biblis C reactor pressure vessel was available. As part of the project, eight reactor pressure vessel head models from this material (22 NiMoCr 3 7) were tested up to rupture at VTT. The specimens were provided by Forschungszentrum Karlsruhe (FzK). These tests were performed under quasistatic pressure load at room temperature. Two specimens sizes were tested and in half of the tests the specimens contain holes describing the control rod penetrations of an actual reactor pressure vessel head. These specimens were equipped with an aluminium liner. All six tests with the smaller specimen size were conducted successfully. In the test with the large specimen with holes, the behaviour of the aluminium liner material proved to differ from those of the smaller ones. As a consequence the experiment ended at the failure of the liner. The specimen without holes yielded results that were in very good agreement with those from the small specimens. (author)

  8. Measurement of highly enriched uranium metal buttons with the high-level neutron coincidence counter operating in the active mode

    International Nuclear Information System (INIS)

    Foley, J.E.

    1980-10-01

    The portable High-Level Neutron Coincidence Counter is used in the active mode with the addition of AmLi neutron sources to assay the 235 U content of highly enriched metal pieces or buttons. It is concluded that the portable instrument is a practical instrument for assaying uranium metal buttons with masses in the range 1.5 to 4 kg

  9. Waiting Time for Coronal Preparation and the Influence of Different Cements on Tensile Strength of Metal Posts

    Directory of Open Access Journals (Sweden)

    Ilione Kruschewsky Costa Sousa Oliveira

    2012-01-01

    Full Text Available This study aimed to assess the effect of post-cementation waiting time for core preparation of cemented cast posts and cores had on retention in the root canal, using two different luting materials. Sixty extracted human canines were sectioned 16 mm from the root apex. After cast nickel-chromium metal posts and cores were fabricated and luted with zinc phosphate (ZP cement or resin cement (RC, the specimens were divided into 3 groups (n = 10 according to the waiting time for core preparation: no preparation (control, 15 minutes, or 1 week after the core cementation. At the appropriate time, the specimens were subjected to a tensile load test (0.5 mm/min until failure. Two-way ANOVA (time versus cement and the Tukey tests (P < 0.05 showed significantly higher (P < 0.05 tensile strength values for the ZP cement groups than for the RC groups. Core preparation and post-cementation waiting time for core recontouring did not influence the retention strength. ZP was the best material for intraradicular metal post cementation.

  10. Tensile and shear bond strength of hard and soft denture relining materials to the conventional heat cured acrylic denture base resin: An In-vitro study.

    Science.gov (United States)

    Lau, Mayank; Amarnath, G S; Muddugangadhar, B C; Swetha, M U; Das, Kopal Anshuraj Ashok Kumar

    2014-04-01

    The condition of the denture bearing tissues may be adversely affected by high stress concentration during function. Chairside Denture (Hard and Soft) reliners are used to distribute forces applied to soft tissues during function. Tensile and shear bond strength has been shown to be dependent on their chemical composition. A weak bond could harbor bacteria, promote staining and delamination of the lining material. To investigate tensile and shear bond strength of 4 different commercially available denture relining materials to conventional heat cured acrylic denture base resin. 4 mm sections in the middle of 160 Acrylic cylindrical specimens (20 mm x 8 mm) were removed, packed with test materials (Mollosil, G C Reline Soft, G C Reline Hard (Kooliner) and Ufi Gel Hard and polymerized. Specimens were divided into 8 groups of 20 each. Tensile and shear bond strength to the conventional heat cured acrylic denture base resin were examined by Instron Universal Tensile Testing Machine using the equation F=N/A (F-maximum force exerted on the specimen (Newton) and A-bonding area= 50.24 mm2). One-way ANOVA was used for multiple group comparisons followed by Bonferroni Test and Hsu's MCB for multiple pairwise comparisons to asses any significant differences between the groups. The highest mean Tensile bond strength value was obtained for Ufi Gel Hard (6.49+0.08 MPa) and lowest for G C Reline Soft (0.52+0.01 MPa). The highest mean Shear bond strength value was obtained for Ufi Gel Hard (16.19+0.1 MPa) and lowest for Mollosil (0.59+0.05 MPa). The Benferroni test showed a significant difference in the mean tensile bond strength and the mean shear bond strength when the two denture soft liners were compared as well as when the two denture hard liners were compared. Hsu's MCB implied that Ufi gel hard is better than its other closest competitors. The Tensile and Shear bond strength values of denture soft reliners were significantly lower than denture hard reliners. How to cite the

  11. Non-linearities in tensile creep of concrete at early age

    DEFF Research Database (Denmark)

    Hauggaard-Nielsen, Anders Boe; Damkilde, Lars

    1997-01-01

    A meterial model for creep is proposed which takes into consideration some of the couplings in early age concrete. The model is in incremental form and reflect the hydration process where new layers of cement gel are formed in a stress free state. In the present context attention is on non......-linear creep at high stress levels. The parameteres in the model develop in time as a result of hydration. The creep model has been used to analyse the tensile experiments at different stress levels carried out in the HETEK project. The tests were made on dogbone shaped specimen and the test procedure...

  12. [Outcomes and complications of Tightrope button plate for repairing acromioclavicular dislocation].

    Science.gov (United States)

    Zuo, Yong-Xiang; Ma, Zi-Ping

    2017-10-25

    To study the clinical outcome and complications of Tightrope button plate for repairing acromioclavicular dislocation of Rockwood type III to V. From May 2014 to December 2016, 17 patients with acromioclavicular dislocation of type III-V were treated with Tightrope button plate including 10 males and 7 females with an average age 39.8 years old ranging from 20 to 68 years old. Four patients were treated with arthroscopy and 17 patients were treated with mini-invasive by X-ray assisted. Shoulder function, X-ray and complications after operation were assessed. All patients were followed up for 5 to 23 months with a mean of 10.8 months. All patients got satisfying reduction immediately postoperatively. Among them, 1 case of clavicle end wound foreign body reaction, rupture, effusion, healing after the second suture; 1 case of foreign body granuloma formation at the end of clavicle were resected and removed at 4 months after operation; 3 cases loss reduction(less than 50% of acromioclavicular joint). No coracoid fracture and suture breakage observed. The shoulder mobility was restored in 15 cases at 4 to 6 weeks postoperatively, and the shoulder adhesion in 2 cases was delayed to 5 to 7 months after operation. The Constant scores were improved from 46.9±6.0 preoperatively to 92.7±4.0 at the final follow-up. X-ray evaluation of postoperative coracoclavicular tunnel location, patients' coracoclavicular tunnel with mini-invasive fluoroscopy all closed to the ideal position (across the clavicle vertically through the coracoid base center), while different degree of tunnel position deviation were observed in arthroscopic patients. Tightrope button plate for the treatment of acromioclavicular joint dislocation had advantages of minimally invasive, effective, good clinical results, the majority of common complications does not affect efficacy. Small incision X-ray method can provide more satisfactory and reliable tunnel location.

  13. Relationship between splitting tensile and compressive strengths for self-compacting concrete containing nano- and micro silica

    Directory of Open Access Journals (Sweden)

    Jaber Ali

    2018-01-01

    Full Text Available This paper describes the relationship between splitting tensile strength and compressive strength of self-consolidating concrete using data collected from laboratory specimens tested at standard conditions. The results were then compared with some expressions published in international literature. The investigated variables included: type of cement, percentage of nanosilica and percentage of microsilica as a cement replacement by weight. In spite of concrete not being designed to resist direct tension the knowledge of tensile strength is needed to estimate the cracking load. In the absence of test results an estimate of the tensile strength may be obtained by using the relationship proposed. The verification of the proposed formula based on experimental data was estimated by means of the integral absolute error (IAE. The output of this study has provided a better understanding of the correlation between splitting and compressive strengths of SCCs and the effect of some related variables on the resultant behavior, which has therefore, helped to generate new expression with better accuracy.

  14. An Experimental Study of the Influence of in-Plane Fiber Waviness on Unidirectional Laminates Tensile Properties

    Science.gov (United States)

    Zhao, Cong; Xiao, Jun; Li, Yong; Chu, Qiyi; Xu, Ting; Wang, Bendong

    2017-12-01

    As one of the most common process induced defects of automated fiber placement, in-plane fiber waviness and its influences on mechanical properties of fiber reinforced composite lack experimental studies. In this paper, a new approach to prepare the test specimen with in-plane fiber waviness is proposed in consideration of the mismatch between the current test standard and actual fiber trajectory. Based on the generation mechanism of in-plane fiber waviness during automated fiber placement, the magnitude of in-plane fiber waviness is characterized by axial compressive strain of prepreg tow. The elastic constants and tensile strength of unidirectional laminates with in-plane fiber waviness are calculated by off-axis and maximum stress theory. Experimental results show that the tensile properties infade dramatically with increasing magnitude of the waviness, in good agreement with theoretical analyses. When prepreg tow compressive strain reaches 1.2%, the longitudinal tensile modulus and strength of unidirectional laminate decreased by 25.5% and 57.7%, respectively.

  15. Irradiation induced tensile property change of SA 508 Cl.3 reactor pressure vessel steels

    International Nuclear Information System (INIS)

    Chi, Se-Hwan; Hong, Jun-Hwa; Kuk, Il-Hiun

    1998-01-01

    Irradiation induced tensile property change of four kinds of reactor pressure vessel steels manufactured by different steel refining process was compared based on the differences in the unirradiated and irradiated microstructure. Microvickers hardness, indentation, and miniature tensile specimen tests were conducted for mechanical property measurement and optical microscope (OM) and transmission electron microscope (TEM) were used for microstructural characterization. Specimens were 2 irradiated to a neutron fluence of 2.7x10 19 n/cm 2 (E ≥ 1 MeV) at 288 deg. C. Investigation on the unirradiated microstructures showed largely a same microstructure in that tempered acicular bainite and ferrite with bainitic phase prevailing in the unirradiated condition. Band-shaped segregations were also clearly observed except a kind of materials. A large difference in the unirradiated microstructure appeared in the grain size and carbide microstructure. Of carbide microstructures, noticeable differences were observed in the size and distribution of cementite, and bainitic lath microstructures. No noticeable changes were observed in the optical and thin film TEM microstructures after irradiation. Complicated microstructural. state of heat treated bainitic low alloy microstructure prevents easy quantification of microstructural changes due to irradiation. Apparent differences, however, were observed in the results of mechanical testing. Results of tensile testing and hardness measurement show that a steel refined by vacuum carbon deoxidation(VCD) method exhibits the highest radiation hardening behavior. Some of mechanical testing results on irradiated materials were possible to understand based on the initial microstructure, but further investigations using a wide array of sophisticated tools (for example, SANS, APFIM) are required to understand and characterize irradiation induced defects that are responsible for irradiation hardening behavior but are not revealed by

  16. Irradiation induced tensile property change of SA 508 Cl. 3 reactor pressure vessel steels

    International Nuclear Information System (INIS)

    Chi, Se Hwan; Hong, Jun Hwa; Kuk, Il Hiun

    1998-01-01

    Irradiation induced tensile property change of four kinds of reactor pressure vessel steels manufactured by different steel refining process was compared based on the differences in the miniature tensile specimen tests were conducted for mechanical property measurement and optical microscope (OM) and transmission electron microscope (TEM) were used for microstructural characterization. Specimens were irradiated to a neutron fluence of 2.7 x 10 19 n/cm 2 (E ≥ 1 MeV) at 288 deg C. Investigation on the unirradiated microstructures showed largely a same microstructure in that tempered acicular bainite and ferrite with bainitic phase prevailing in the unirradiated condition. Ban-shaped segregations were also clearly observed except a kind of materials. A large difference in the unirradiated microstructure appeared in the grain size and carbide microstructure. Of carbide microstructures, noticeable differences were observed in the size and distribution of cementite, and bainitic lath microstructures. No noticeable changes were observed in the optical and thin film TEM microstructures after irradiation. Complicated microstructural state of heat treated bainitic low alloy microstructure prevents easy quantification of microstructural changes due to irradiation. Apparent differences, however, were observed in the results of mechanical testing. Results of tensile testing and hardness measurement show that a steel refined by vacuum carbon deoxidation (VCD) method exhibits the highest radiation hardening behavior. Some of mechanical testing results on irradiated materials were possible to understand based on the initial microstructure, but further investigations using a wide array of sophisticated tools (for example, SANS, APFIM) are required to understand and characterize irradiation induced defects that are responsible for irradiation hardening behavior but are not revealed by conventional TEM. (author)

  17. Tensile characterisation of the aorta across quasi-static to blast loading strain rates

    Science.gov (United States)

    Magnus, Danyal; Proud, William; Haller, Antoine; Jouffroy, Apolline

    2017-06-01

    The dynamic tensile failure mechanisms of the aorta during Traumatic Aortic Injury (TAI) are poorly understood. In automotive incidents, where the aorta may be under strains of the order of 100/s, TAI is the second largest cause of mortality. In these studies, the proximal descending aorta is the most common site where rupture is observed. In particular, the transverse direction is most commonly affected due to the circumferential orientation of elastin, and hence the literature generally concentrates upon axial samples. This project extends these dynamic studies to the blast loading regime where strain-rates are of the order of 1000/s. A campaign of uniaxial tensile experiments are conducted at quasi-static, intermediate (drop-weight) and high (tensile Split-Hopkinson Pressure Bar) strain rates. In each case, murine and porcine aorta models are considered and the extent of damage assessed post-loading using histology. Experimental data will be compared against current viscoelastic models of the aorta under axial stress. Their applicability across strain rates will be discussed. Using a multi-disciplinary approach, the conditions applied to the samples replicate in vivo conditions, employing a blood simulant-filled tubular specimen surrounded by a physiological solution.

  18. MRTouch: Adding Touch Input to Head-Mounted Mixed Reality.

    Science.gov (United States)

    Xiao, Robert; Schwarz, Julia; Throm, Nick; Wilson, Andrew D; Benko, Hrvoje

    2018-04-01

    We present MRTouch, a novel multitouch input solution for head-mounted mixed reality systems. Our system enables users to reach out and directly manipulate virtual interfaces affixed to surfaces in their environment, as though they were touchscreens. Touch input offers precise, tactile and comfortable user input, and naturally complements existing popular modalities, such as voice and hand gesture. Our research prototype combines both depth and infrared camera streams together with real-time detection and tracking of surface planes to enable robust finger-tracking even when both the hand and head are in motion. Our technique is implemented on a commercial Microsoft HoloLens without requiring any additional hardware nor any user or environmental calibration. Through our performance evaluation, we demonstrate high input accuracy with an average positional error of 5.4 mm and 95% button size of 16 mm, across 17 participants, 2 surface orientations and 4 surface materials. Finally, we demonstrate the potential of our technique to enable on-world touch interactions through 5 example applications.

  19. Modelling of the deformation of shot peened cylindrical specimens of 42 CrMo4 in uniaxial tension and deformation and of the resulting macro residual stresses; Modellierung der einachsigen Zug- und Druck-Verformung kugelgestrahlter Zylinderproben aus verguetetem 42 CrMo4 und der dabei auftretenden Makroeigenspannungsaenderungen

    Energy Technology Data Exchange (ETDEWEB)

    Schulze, V.; Voehringer, O.; Macherauch, E. [Karlsruhe Univ. (T.H.) (Germany). Inst. fuer Werkstoffkunde 1

    1998-10-01

    Tensile and compressive stress-strain-curves of shot peened and unpeened specimens of quenched and tempered 42 CrMo 4 (AISI 4140) with a diameter of 5 mm only differ in the yield strengths and in the Lueders-deformation. In comparison to the core the regions close to the surface of shot peened cylindrical specimens bear relatively large axial and tangential residual stresses and show different deformation properties. A multi-layer-model was developed to describe both the tensile as well as the compressive deformation behaviour of shot peened cylindrical specimens quantitatively. The calculated transitions from the elastic to the elastic-plastic deformation state during tensile and compressive loading agree quite well with the experimental observations. Also the changes of axial and tangential macro residual stresses after distinct tensile or compressive deformations are in best agreement with the measurements. (orig.) 29 refs.

  20. Quasi-static and dynamic experimental studies on the tensile strength and failure pattern of concrete and mortar discs.

    Science.gov (United States)

    Jin, Xiaochao; Hou, Cheng; Fan, Xueling; Lu, Chunsheng; Yang, Huawei; Shu, Xuefeng; Wang, Zhihua

    2017-11-10

    As concrete and mortar materials widely used in structural engineering may suffer dynamic loadings, studies on their mechanical properties under different strain rates are of great importance. In this paper, based on splitting tests of Brazilian discs, the tensile strength and failure pattern of concrete and mortar were investigated under quasi-static and dynamic loadings with a strain rate of 1-200 s -1 . It is shown that the quasi-static tensile strength of mortar is higher than that of concrete since coarse aggregates weaken the interface bonding strength of the latter. Numerical results confirmed that the plane stress hypothesis lead to a lower value tensile strength for the cylindrical specimens. With the increase of strain rates, dynamic tensile strengths of concrete and mortar significantly increase, and their failure patterns change form a single crack to multiple cracks and even fragment. Furthermore, a relationship between the dynamic increase factor and strain rate was established by using a linear fitting algorithm, which can be conveniently used to calculate the dynamic increase factor of concrete-like materials in engineering applications.

  1. An Electron Microscope Study of the Thermal Neutron Induced Loss in High Temperature Tensile Ductility of Nb Stabilized Austenitic Steels

    Energy Technology Data Exchange (ETDEWEB)

    Roy, R B

    1965-04-15

    Irradiated {approx}3 x 10{sup 19} n/cm{sup 2} (thermal), <3 x 10{sup 18} n/cm{sup 2} (> 1 MeV) at 40 deg C and the corresponding unirradiated control tensile specimens of a 20 % Cr, 25 % Ni, Nb stabilized steel tested at 650 deg C, 750 deg C and 800 deg C have been examined by transmission electron microscopy. The results indicate that the irradiation induced embrittlement of the tensile specimens at elevated temperatures is preceded by the formation of fine precipitates within the grains. These precipitates may restrict the deformation within the grains such that the stresses are concentrated at the grain boundaries thereby leading to premature failure. It is suggested that the main effect of the irradiation is to promote conditions necessary for the formation of these precipitates, namely, super saturation and fresh nucleation sites within the matrix through the energetic emission of He and Li atoms from boron as an impurity.

  2. Development of stress relaxation measurement by a small size C-ring specimen method

    International Nuclear Information System (INIS)

    Shimanuki, Shizuka; Nakata, Kiyotomo; Kasahara, Shigeki; Kuniya, Jiro

    2002-01-01

    A stress relaxation measurement method has been developed by using C-ring specimens, and a specimen size effect has been evaluated taking radiation-induced stress relaxation into consideration. C-ring specimens were stressed by forcing a wedge in the gap. Giving an appropriate eccentric configuration in the half of the ring opposite the gap, the stress gradient along the circumference was eliminated in the section and the stress level could be varied by changing the gap spacing. The validity of the C-ring test method was confirmed by thermally stress relaxation experiments at annealing temperatures from 300 to 600degC for 1 min to 200 h in carbon steel: considerable stress relaxation could be measured for all levels of applied stress even at relatively low annealing temperatures. The relaxation results obtained from the C-ring test were in good agreement with those from a uniaxial tensile stress relaxation test. The smaller C-ring specimen with about 40 mm diameter, which is required for radiation-induced stress relaxation test, also showed adequate accuracy on stress relaxation at 600 to 830degC in stainless steel, compared with the large size C-ring specimen test. (author)

  3. Analysis of Ninety Degree Flexure Tests for Characterization of Composite Transverse Tensile Strength

    Science.gov (United States)

    OBrien, T. Kevin; Krueger, Ronald

    2001-01-01

    Finite element (FE) analysis was performed on 3-point and 4-point bending test configurations of ninety degree oriented glass-epoxy and graphite-epoxy composite beams to identify deviations from beam theory predictions. Both linear and geometric non-linear analyses were performed using the ABAQUS finite element code. The 3-point and 4-point bending specimens were first modeled with two-dimensional elements. Three-dimensional finite element models were then performed for selected 4-point bending configurations to study the stress distribution across the width of the specimens and compare the results to the stresses computed from two-dimensional plane strain and plane stress analyses and the stresses from beam theory. Stresses for all configurations were analyzed at load levels corresponding to the measured transverse tensile strength of the material.

  4. Tensile properties of four types of austenitic stainless steel welded joints

    International Nuclear Information System (INIS)

    Balladon, P.

    1990-01-01

    In the field of an LMFBR research programme on austenitic stainless steel welds in a Shared Cost Action Safety, Research Area 8, coordinated by JRC-Ispra, four cooperating laboratories (ECN, IKE/MPA, the Welding Institute and UNIREC) have been involved in the fabrication and extensive characterization of welded joints made from one plate of ICL 167 stainless steel. The materials included parent metal, four vacuum electron beam welds, one non vacuum electron beam weld, one submerged arc weld, one gas metal arc weld and one manual metal arc weld. This report summarizes the 106 tensile tests performed at room temperature and 550 0 C, including the influence of strain rate, specimen orientation and welding procedure. Main results are that electron beam welds have tensile properties close to those of parent metal with higher values of yield strength in longitudinal orientation and lower values of total elongation in transverse orientation but with a similar reduction of area, that filler metal welds own the highest values of yield strength and lowest values of ductility. Most of the welds properties are higher than the minimum specified for parent metal, except for some values of total elongation, mainly in transverse orientation. In view of using electron beam welding for production of components used in LMFBR, results obtained show that tensile properties of electron beam welds compare well to those of classical welds. (author)

  5. Modelling and Simulation of Tensile Fracture in High Velocity Compacted Metal Powder

    International Nuclear Information System (INIS)

    Jonsen, P.; Haeggblad, H.-A.

    2007-01-01

    In cold uniaxial powder compaction, powder is formed into a desired shape with rigid tools and a die. After pressing, but before sintering, the compacted powder is called green body. A critical property in the metal powder pressing process is the mechanical properties of the green body. Beyond a green body free from defects, desired properties are high strength and uniform density. High velocity compaction (HVC) using a hydraulic operated hammer is a production method to form powder utilizing a shock wave. Pre-alloyed water atomised iron powder has been HVC-formed into circular discs with high densities. The diametral compression test also called the Brazilian disc test is an established method to measure tensile strength in low strength material like e.g. rock, concrete, polymers and ceramics. During the test a thin disc is compressed across the diameter to failure. The compression induces a tensile stress perpendicular to the compressed diameter. In this study the test have been used to study crack initiation and the tensile fracture process of HVC-formed metal powder discs with a relative density of 99%. A fictitious crack model controlled by a stress versus crack-width relationship is utilized to model green body cracking. Tensile strength is used as a failure condition and limits the stress in the fracture interface. The softening rate of the model is obtained from the corresponding rate of the dissipated energy. The deformation of the powder material is modelled with an elastic-plastic Cap model. The characteristics of the tensile fracture development of the central crack in a diametrically loaded specimen is numerically studied with a three dimensional finite element simulation. Results from the finite element simulation of the diametral compression test shows that it is possible to simulate fracturing of HVC-formed powder. Results from the simulation agree reasonably with experiments

  6. Study of austenitic stainless steel welded with low alloy steel filler metal. [tensile and impact strength tests

    Science.gov (United States)

    Burns, F. A.; Dyke, R. A., Jr.

    1979-01-01

    The tensile and impact strength properties of 316L stainless steel plate welded with low alloy steel filler metal were determined. Tests were conducted at room temperature and -100 F on standard test specimens machined from as-welded panels of various chemical compositions. No significant differences were found as the result of variations in percentage chemical composition on the impact and tensile test results. The weldments containing lower chromium and nickel as the result of dilution of parent metal from the use of the low alloy steel filler metal corroded more severely in a marine environment. The use of a protective finish, i.e., a nitrile-based paint containing aluminum powder, prevented the corrosive attack.

  7. Revised ANL-reported tensile data for V-Ti and V-Cr-Ti alloys

    Energy Technology Data Exchange (ETDEWEB)

    Billone, M.C. [Argonne National Lab., IL (United States)

    1997-08-01

    The tensile for all irradiated vanadium alloy samples and several unirradiated vanadium alloys tested at Argonne National Laboratory (ANL) have been critically reviewed and revised, as necessary. The review and revision are based on re-analyzing the original load-displacement strip-chart recording using a methodology consistent with current ASTM standards. No significant difference has been found between the newly-revised and previously-reported values of yield strength (YS) and ultimate tensile strength (UTS). However, by correctly subtracting the non-gauge-length displacement and linear gauge-length displacement from the total cross-head displacement, the uniform elongation (UE) of the gauge length decreases by 4-9% strain and the total elongation (TE) of the gauge length decreases by 1-7% strain. These differences are more significant for lower-ductility irradiated alloys than for higher-ductility alloys.

  8. Revised ANL-reported tensile data for V-Ti and V-Cr-Ti alloys

    International Nuclear Information System (INIS)

    Billone, M.C.

    1997-01-01

    The tensile for all irradiated vanadium alloy samples and several unirradiated vanadium alloys tested at Argonne National Laboratory (ANL) have been critically reviewed and revised, as necessary. The review and revision are based on re-analyzing the original load-displacement strip-chart recording using a methodology consistent with current ASTM standards. No significant difference has been found between the newly-revised and previously-reported values of yield strength (YS) and ultimate tensile strength (UTS). However, by correctly subtracting the non-gauge-length displacement and linear gauge-length displacement from the total cross-head displacement, the uniform elongation (UE) of the gauge length decreases by 4-9% strain and the total elongation (TE) of the gauge length decreases by 1-7% strain. These differences are more significant for lower-ductility irradiated alloys than for higher-ductility alloys

  9. Tensile properties of orthodontic elastomeric ligatures.

    Science.gov (United States)

    Ahrari, F; Jalaly, T; Zebarjad, M

    2010-01-01

    Tensile properties of elastomeric ligatures become important when efficiency of orthodontic appliances is considered. The aim of this study was to compare tensile strength, extension to tensile strength, toughness and modulus of elasticity of elastomeric ligatures in both the as--received condition and after 28 days of immersion in the simulated oral environment. Furthermore, the changes that occurred in tensile properties of each brand of ligatures after 28 days were evaluated. Experimental-laboratory based. Elastomeric ligatures were obtained from different companies and their tensile properties were measured using Zwick testing machine in both the as-received condition and after 28 days of immersion in the simulated oral environment. The data were analyzed using independent sample t-tests, analysis of variance and Tukey tests. After 28 days, all the ligatures experienced a significant decrease in tensile strength, extension to tensile strength and toughness ( P tensile properties of different brands of ligatures in both conditions ( P tensile properties of different brands of ligatures, which should be considered during selection of these products.

  10. Importance of Tensile Strength on the Shear Behavior of Discontinuities

    Science.gov (United States)

    Ghazvinian, A. H.; Azinfar, M. J.; Geranmayeh Vaneghi, R.

    2012-05-01

    In this study, the shear behavior of discontinuities possessing two different rock wall types with distinct separate compressive strengths was investigated. The designed profiles consisted of regular artificial joints molded by five types of plaster mortars, each representing a distinct uniaxial compressive strength. The compressive strengths of plaster specimens ranged from 5.9 to 19.5 MPa. These specimens were molded considering a regular triangular asperity profile and were designed so as to achieve joint walls with different strength material combinations. The results showed that the shear behavior of discontinuities possessing different joint wall compressive strengths (DDJCS) tested under constant normal load (CNL) conditions is the same as those possessing identical joint wall strengths, but the shear strength of DDJCS is governed by minor joint wall compressive strength. In addition, it was measured that the predicted values obtained by Barton's empirical criterion are greater than the experimental results. The finding indicates that there is a correlation between the joint roughness coefficient (JRC), normal stress, and mechanical strength. It was observed that the mode of failure of asperities is either pure tensile, pure shear, or a combination of both. Therefore, Barton's strength criterion, which considers the compressive strength of joint walls, was modified by substituting the compressive strength with the tensile strength. The validity of the modified criterion was examined by the comparison of the predicted shear values with the laboratory shear test results reported by Grasselli (Ph.D. thesis n.2404, Civil Engineering Department, EPFL, Lausanne, Switzerland, 2001). These comparisons infer that the modified criterion can predict the shear strength of joints more precisely.

  11. Study of root tensile strength of softwood and hardwood tree species: Implications for slope stability

    Science.gov (United States)

    Esmaiili, Marzieh; Abdi, Ehsan; Jafary, Mohammad; Majnounian, Baris

    2017-04-01

    Landslides are known as one of the major natural hazards and often incurring economics and human life losses. The role of tree roots in slope stability is very important, especially when human lives and infrastructure are at risk. The anchorage of roots and improvement of slope stability mainly depend on specific properties of root network systems, such as tensile strength. These properties of the roots which govern the degree of reinforcement are different among tree species. Although, many studies have been conducted about plant biotechnical properties of species, yet there is lack of knowledge on comparing root systems of softwood and hardwood tree species for similar site conditions. Therefore this study was conducted to assess the tensile strength of the root system of Picea abies (softwood species) and Fraxinus excelsior (hardwood species) planted on two forested hillslopes. To this aim, single root specimens were sampled for each species and their tensile strength were then measured in laboratory using a computer controlled Instron Universal Testing Machine. According to the results root tensile strength tends to decrease with diameter according to a power law for both species. Based on analysis of covariance (ANCOVA), a significant difference has been observed in the tensile strength between the two studied species. Also the results showed that the value of mean root tensile strength for Picea abies (19.31 ± 2.64 MPa) was much more than that of Fraxinus excelsior (16.98 ± 1.01 MPa) within all root diameter classes. The data presented in this study may expand the knowledge of biotechnical properties of Picea abies and Fraxinus excelsior, as biomaterial for soil bioengineering.

  12. Further miniaturisation of the Thermochron iButton to create a thermal bio-logger weighing 0.3 g.

    Science.gov (United States)

    Virens, Josef; Cree, Alison

    2018-06-05

    Thermochron iButtons are commonly used by thermal biologists to continuously measure body temperature from animals. However, if unmodified, these devices are of a size that limits their use with very small animals. To allow iButtons to be used to study smaller species, methods to miniaturise them by 61% have been previously described. We present a method to reduce iButton mass by a further 71%. The modified devices have a shorter battery life, but the minimum size of vertebrates able to carry the devices is reduced from 28.9 g to 6.6 g, if the arbitrary, yet widely cited, maximum of 5% body mass for attached devices is adhered to. We demonstrate the application of our method by recording surface temperatures of captive and wild skinks and show that captive cockroaches weighing 0.8 g are also able to carry the device. We believe this to be the first time that temperature data have been recorded from an insect in this way. © 2018. Published by The Company of Biologists Ltd.

  13. Tensile properties of neutron irradiated solid HIP 316L(N). ITER Task T214, NET deliverable GB6 ECN-5

    International Nuclear Information System (INIS)

    Van Osch, E.V.; Tjoa, G.L.; Boskeljon, J.; Van Hoepen, J.

    1998-05-01

    The tensile properties of neutron irradiated Hot Isostatically Pressed (HIP) joints of type 316L(N) stainless steel (heat PM-130) have been measured. Cylindrical tensile test specimens of 4 mm diameter were irradiated in the High Flux Reactor (HFR) in Petten, The Netherlands, simulating the first wall conditions by a combination of high displacement damage with proportional amounts of helium. The solid HIP specimens were irradiated up to a target dose level of 5 dpa at a temperature of 550K. The damage levels realized range from 3.0 to 4.1 dpa, with helium contents up to 38 appm. Post irradiation testing temperatures ranged from 300 to 700K. The report contains the experimental conditions and summarises the results, which are given in terms of engineering stresses and strains and reduction of area. The main conclusions are that the unirradiated solid-HIP material is very soft, assumingly due to the relatively large grain size. Neutron irradiation induces both hardening and reduction of ductility, similar to the behaviour of 316L(N) plate. No failures related to debonding were observed for the tests of the unirradiated samples, however one of eight tested irradiated specimens fractured in the HIP joint, showing a flat fracture surface and a low reduction of area. 6 refs

  14. Strain transfer through film-substrate interface and surface curvature evolution during a tensile test

    Science.gov (United States)

    He, Wei; Han, Meidong; Goudeau, Philippe; Bourhis, Eric Le; Renault, Pierre-Olivier; Wang, Shibin; Li, Lin-an

    2018-03-01

    Uniaxial tensile tests on polyimide-supported thin metal films are performed to respectively study the macroscopic strain transfer through an interface and the surface curvature evolution. With a dual digital image correlation (DIC) system, the strains of the film and the substrate can be simultaneously measured in situ during the tensile test. For the true strains below 2% (far beyond the films' elastic limit), a complete longitudinal strain transfer is present irrespective of the film thickness, residual stresses and microstructure. By means of an optical surface profiler, the three-dimensional (3D) topography of film surface can be obtained during straining. As expected, the profile of the specimen center remains almost flat in the tensile direction. Nevertheless, a relatively significant curvature evolution (of the same order with the initial curvature induced by residual stresses) is observed along the transverse direction as a result of a Poisson's ratio mismatch between the film and the substrate. Furthermore, finite element method (FEM) has been performed to simulate the curvature evolution considering the geometric nonlinearity and the perfect strain transfer at the interface, which agrees well with the experimental results.

  15. The color changes and tensile properties of oxidized Ti–6A1–2Mo–1.5Cr–2Zr–2Sn–2Nb alloy

    International Nuclear Information System (INIS)

    Jia, Zhiqiang; Zeng, Weidong; Zhang, Yaowu; Shi, Chunling; Quan, Biao; Wu, Jianding

    2015-01-01

    Highlights: • The oxidized alloy exhibited notable color changes. • The color was mainly attributed to the mixing of titanium oxides. • A corresponding relation between the color and tensile properties was established. • A predicted model was proposed to characterize the diffusion of oxygen. - Abstract: The oxidation of titanium alloy at elevated temperature severely limits its property and service life. It is a common and urgent issue to assess the mechanical property of oxidized titanium component without destroying its structural integrity. In this work, the color changes and tensile properties of oxidized Ti–6A1–2Mo–1.5Cr–2Zr–2Sn–2Nb alloy with initial basket-weave microstructure were investigated in the temperature range of 100–1000 °C. It was found that the oxidized specimens exhibited brilliant and regular color changes. X-ray diffraction (XRD) analysis indicated that the color changes were mainly attributed to the mixing of colored titanium oxides in the oxidation layer (such as yellow TiO, white TiO 2 and blue Ti 2 O 3 ). It was also found that mechanical properties were significant influenced by the oxidation treatment. The specimens oxidized below 600 °C exhibited excellent strength and plasticity due to its fine basket-weave microstructure and dense oxidation layer. In the temperature range from 600 to 800 °C, the strength slightly decreased while the plasticity rose a little. The change of mechanical properties during the temperature range was mainly determined by the microstructure change. Eventually, both strength and plasticity decreased sharply when the temperature was over 800 °C, which was mainly caused by the thick oxidation layer with porous and loose microstructure. The fracture mode of tensile specimens also changed from ductile fracture (below 800 °C) to transgranular cleavage fracture (over 800 °C). On the basis of experiments, a corresponding relation between the color changes and tensile properties was

  16. An Experimental Study of Circular Cutout Hole Effect of Kevlar/epoxy-Al2O3 Composite under Subjected to Quasi-Static Compressive and Tensile Loading

    Directory of Open Access Journals (Sweden)

    Ayad Abed Ramadhan

    2017-12-01

    Full Text Available This paper has presented an experimental study of quasi-static compressive and tensile loading of cutout hole specimens of Kevlar-29/epoxy-Al2O3 laminated composite. The experimental procedure hasbeen developed to study the performance of (50%, 55% and 60% volume fraction (vf and (0o/90o and +45o/-45o fiber orientation angle effects of these composites under quasi-static tensile and compressiveload using a servo-hydraulic testing machine. The study was concluded that the ultimate load capacity increases as volume fraction increases in tensile test. While, the maximum load bearing capacity increaseswith the decrease of volume fraction in compression test. Hence, from the results obtained it can have considered the 55% volume fraction of composite panels is a good value for tensile and compressionapplications.

  17. The Static and Fatigue Behavior of AlSiMg Alloy Plain, Notched, and Diamond Lattice Specimens Fabricated by Laser Powder Bed Fusion

    Directory of Open Access Journals (Sweden)

    Hugo Soul

    2018-04-01

    Full Text Available The fabrication of engineered lattice structures has recently gained momentum due to the development of novel additive manufacturing techniques. Interest in lattice structures resides not only in the possibility of obtaining efficient lightweight materials, but also in the functionality of pre-designed architectured structures for specific applications, such as biomimetic implants, chemical catalyzers, and heat transfer devices. The mechanical behaviour of lattice structures depends not only the composition of the base material, but also on the type and size of the unit cells, as well as on the material microstructure resulting from a specific fabrication procedure. The present work focuses on the static and fatigue behavior of diamond cell lattice structures fabricated from an AlSiMg alloy by laser powder bed fusion technology. In particular, the specimens were fabricated with three different orientations of lattice cells—[001], [011], [111]—and subjected to static tensile testing and force-controlled pull–pull fatigue testing up to 1 × 107 cycles. In parallel, the mechanical behavior of dense tensile plain and notched specimens was also studied and compared to that of their lattice counterparts. Results showed a significant effect of the cell orientation on the fatigue lives: specimens oriented at [001] were ~30% more fatigue-resistant than specimens oriented at [011] and [111].

  18. The effect of thermal treatment on the mechanical properties of PLLA tubular specimens

    Directory of Open Access Journals (Sweden)

    Arbeiter Daniela

    2016-09-01

    Full Text Available Conventional permanent stent systems for vascular applications are associated with long-term risks, such as restenosis and thrombosis. To overcome these limitations, novel approaches using various biodegradable materials for stent construction have been investigated. In this context, thermal treatment of polymer materials is investigated to adjust the mechanical properties of biodegradable stents. In this work polymeric tubular specimens of biodegradable poly(L-lactide (PLLA were extruded and subjected to a molding process using different temperatures above glass transition temperature TG. Physicochemical properties of the molded samples were analyzed using DSC measurements and uniaxial tensile tests. The molding process resulted in a weakening of the PLLA tubular specimens with a simultaneous increase in the degree of crystallinity (χ.

  19. Thermal and stress analyses of the reactor pressure vessel lower head of the Three Mile Island Unit 2

    International Nuclear Information System (INIS)

    Hashimoto, K.; Onizawa, K.; Kurihara, R.; Kawasaki, S.; Soda, K.

    1992-01-01

    Thermal and stress analyses were performed using the finite element analysis code ABAQUS to clarify the factors which caused tears in the stainless steel liner of the reactor pressure vessel lower head of the Three Mile Island Unit 2 (TMI-2) reactor pressure vessel during the accident on 28 March 1979. The present analyses covered the events which occurred after approximately 20 tons of molten core material were relocated to the lower head of the reactor pressure vessel. They showed that the tensile stress was highest in the case where the relocated core material consisting of homogeneous UO 2 debris was assumed to attack the lower head and the debris was then quenched. The peak tensile stress was in the vicinity of the welded zone of the penetration nozzle. This result agrees with the findings from the examination of the TMI-2 reactor pressure vessel that major tears in the stainless steel liner were observed around two penetration nozzles of the lower head. (author)

  20. A study on preparation of cross sectional anatomy specimen of cadaver

    International Nuclear Information System (INIS)

    Im, C. K.; Choi, B. I.; Park, J. H.; Chang, K. H.; Yeon, K. M.; Han, M. C.; Kim, C. W.

    1984-01-01

    With the advent of cross sectional image of CT, ultrasound and magnetic resonance, the need for knowledge of cross sectional anatomy is stranger than ever. To meet this need, preparation of cross sectional anatomy specimen using cadaver is indispensable, not only because it tis the real cut surface anatomy but also because overt limitations of radiographic image in both contrast and special resolution. Authors prepared cross sectional anatomy specimen using a male cadaver, comprising photographs and slides of the 60 cross cut slices from the head to the pelvis. After photography, each slices was embedded using transparent resin allowing permanent preservation of specimen without altering its original architecture. Author's unique method of preparation is presented and 4 representative specimens are illustrated comparing cadaver's CT image, cross cut surface photography, and photography of resin embedded slice of the same cut surface.

  1. Text Fixture for Double Cantilever Beam (DCB) Specimens Subjected to Uneven Bending Moments

    DEFF Research Database (Denmark)

    Svenninggaard, Jon; Andreasen, Jens; Bak, Brian

    Bending Moments as a function of the phase angle ranging from mode I to mode II loading including mixed modes in-between. The test fixture utilizes an existing tensile testing machine and can subject specimens to loads up to 350 Nm. The test fixture is compact in size and designed using standard aluminium...... profiles for the main structure. The load is transferred from the test machine to the specimen through a 2 mm Dyneema rope. The rope is routed over a set of rollers that are positioned according to the specified mode mixity and phase angle. The kinematics of the test fixture has been analysed extensively...... strength in layered materials the cohesive law and fracture strength must be known. Ideally the entire cohesive law is known in order to aid in the design of components and structures. In this work we present a novel test fixture which can be used to test DCB specimens that are subjected to pure Uneven...

  2. A Geant4 evaluation of the Hornyak button and two candidate detectors for the TREAT hodoscope

    Science.gov (United States)

    Fu, Wenkai; Ghosh, Priyarshini; Harrison, Mark J.; McGregor, Douglas S.; Roberts, Jeremy A.

    2018-05-01

    The performance of traditional Hornyak buttons and two proposed variants for fast-neutron hodoscope applications was evaluated using Geant4. The Hornyak button is a ZnS(Ag)-based device previously deployed at the Idaho National Laboratory's TRansient REActor Test Facility (better known as TREAT) for monitoring fast neutrons emitted during pulsing of fissile fuel samples. Past use of these devices relied on pulse-shape discrimination to reduce the significant levels of background Cherenkov radiation. Proposed are two simple designs that reduce the overall light guide mass (here, polymethyl methacrylate or PMMA), employ silicon photomultipliers (SiPMs), and can be operated using pulse-height discrimination alone to eliminate background noise to acceptable levels. Geant4 was first used to model a traditional Hornyak button, and for assumed, hodoscope-like conditions, an intrinsic efficiency of 0.35% for mono-directional fission neutrons was predicted. The predicted efficiency is in reasonably good agreement with experimental data from the literature and, hence, served to validate the physics models and approximations employed. Geant4 models were then developed to optimize the materials and geometries of two alternatives to the Hornyak button, one based on a homogeneous mixture of ZnS(Ag) and PMMA, and one based on alternating layers of ZnS(Ag) and PMMA oriented perpendicular to the incident neutron beam. For the same radiation environment, optimized, 5-cm long (along the beam path) devices of the homogeneous and layered designs were predicted to have efficiencies of approximately 1.3% and 3.3%, respectively. For longer devices, i.e., lengths larger than 25 cm, these efficiencies were shown to peak at approximately 2.2% and 5.9%, respectively. Moreover, both designs were shown to discriminate Cherenkov noise intrinsically by using an appropriate pulse-height discriminator level, i.e., pulse-shape discrimination is not needed for these devices.

  3. Aging effects on fracture behavior of 63Sn37Pb eutectic solder during tensile tests under the SEM

    International Nuclear Information System (INIS)

    Ding Ying; Wang Chunqing; Li Mingyu; Bang Hansur

    2004-01-01

    This study investigates the influence of aging treatment on fracture behavior of Sn-Pb eutectic solder alloys at different loading rate regime during tensile tests under the scanning electron microscope. In high homologous temperature, the solder exhibit the creep behavior that could be confirmed through the phenomena of grain boundary sliding (GBS) to both as-cast and aged specimens. Owing to the large grain scale after high temperature storage, boundary behavior was limited to some extent for the difficulty in grain rotation and boundary migration. Instead, drastic intragranular deformation occurred. Also, the phase coarsening weakened the combination between lead-rich phase and tin matrix. Consequently, surface fragmentation was detected for the aged specimens. Furthermore, the fracture mechanism changed from intergranular dominated to transgranular dominated with increasing loading rate to both specimens during early stage

  4. Tensile behavior of Inconel alloy X-750 in air and vacuum at elevated temperatures

    International Nuclear Information System (INIS)

    Taplin, D.M.R.; Mukherjee, A.K.; Pandey, M.C.

    1984-01-01

    The hot tensile properties of Inconel alloy X-750 have been investigated experimentally at 700 C in air and vacuum at strain rates varying from 10 to the -7th to 1.2 x 10 to the -6th per s. The strength and ductile characteristics of the specimens tested in vacuum are found to be better than those tested in air. In air, a ductility minimum is observed at 625 C, whereas in vacuum, significant improvements in creep ductility are observed at 575 and 625 C, with the ductility minimum shifting from 625 to 700 C. It is shown that the creep ductility of the specimens tested in air is largely determined by the following two competing processes: (1) deformation-assisted oxygen diffusion and (2) grain boundary migration. 20 references

  5. Results of the Electron-Beam Button Melting of very clean Ni-base superalloys for the identification of nonmetallic inclusions

    Energy Technology Data Exchange (ETDEWEB)

    Hauner, F.; Stephan, H.; Stumpp, H.

    1986-02-01

    The reliability of components made of high strength materials is substantially influenced by their cleanliness. For example, the ductility, the fatigue-characteristics and the stress resistance of high strength alloys can be improved by increasing the cleanliness along with decreasing the inclusion size to below 25 ..mu..m. For the analysis of such high clean alloys with decreasing size of nonmetallic inclusions, the metallographic texting methods become troublesome and inexact for a dependable quality control. The Electron-Beam Button Melt Test offers a possibility for the examination and qualification of the small amounts of different inclusions in the high clean materials. During a process-controlled melting procedure, inclusions of high density sink to the bottom of a water-cooled copper crucible. Low density inclusions float to the pool surface and are concentrated in the upper center of the button by means of a controlled solidification of the melting pool. For the utilization of the process in the production quality control, development and research, we have developed the Electron-Beam Button Melting Furnace ES 1/07/30 B. In this paper we will present results of the application of the ES1/07/30 B. In this paper we will present results of the application of the ES 1/07/30 B to the EB-Button melting of the Ni-Base Superalloys IN718 and Astroloy. (orig.).

  6. Measurements of radiated elastic wave energy from dynamic tensile cracks

    Science.gov (United States)

    Boler, Frances M.

    1990-01-01

    The role of fracture-velocity, microstructure, and fracture-energy barriers in elastic wave radiation during a dynamic fracture was investigated in experiments in which dynamic tensile cracks of two fracture cofigurations of double cantilever beam geometry were propagating in glass samples. The first, referred to as primary fracture, consisted of fractures of intact glass specimens; the second configuration, referred to as secondary fracture, consisted of a refracture of primary fracture specimens which were rebonded with an intermittent pattern of adhesive to produce variations in fracture surface energy along the crack path. For primary fracture cases, measurable elastic waves were generated in 31 percent of the 16 fracture events observed; the condition for radiation of measurable waves appears to be a local abrupt change in the fracture path direction, such as occurs when the fracture intersects a surface flaw. For secondary fractures, 100 percent of events showed measurable elastic waves; in these fractures, the ratio of radiated elastic wave energy in the measured component to fracture surface energy was 10 times greater than for primary fracture.

  7. Tensile Stress-Strain Results for 304L and 316L Stainless-Steel Plate at Temperature

    International Nuclear Information System (INIS)

    R. K. Blandford; D. K. Morton; S. D. Snow; T. E. Rahl

    2007-01-01

    The Idaho National Laboratory (INL) is conducting moderate strain rate (10 to 200 per second) research on stainless steel materials in support of the Department of Energy's (DOE) National Spent Nuclear Fuel Program (NSNFP). For this research, strain rate effects are characterized by comparison to quasi-static tensile test results. Considerable tensile testing has been conducted resulting in the generation of a large amount of basic material data expressed as engineering and true stress-strain curves. The purpose of this paper is to present the results of quasi-static tensile testing of 304/304L and 316/316L stainless steels in order to add to the existing data pool for these materials and make the data more readily available to other researchers, engineers, and interested parties. Standard tensile testing of round specimens in accordance with ASTM procedure A 370-03a were conducted on 304L and 316L stainless-steel plate materials at temperatures ranging from -20 F to 600 F. Two plate thicknesses, eight material heats, and both base and weld metal were tested. Material yield strength, Young's modulus, ultimate strength, ultimate strain, failure strength and failure strain were determined, engineering and true stress-strain curves to failure were developed, and comparisons to ASME Code minimums were made. The procedures used during testing and the typical results obtained are described in this paper

  8. Construction of cryogenic testing system and tensile deformation behavior of AISI 300 series stainless steels at cryogenic temperatures

    International Nuclear Information System (INIS)

    Lee, H.M.; Nahm, S.H.; Huh, Y.H.; Lee, J.J.; Bahng, G.W.

    1990-01-01

    For practical application of cryogenic engineering, development and characterization of structural materials for use at low temperatures are essential. For these purposes, a system for mechanical testing at liquid helium temperatures was developed and it was shown that the precision and accuracy of the system met the requirements of standards for materials testing machines. Using this system, tensile deformation behavior of AISI 304,316 and 310S austenitic stainless steels at cryogenic temperatures was investigated. Tests were conducted on round, tensile specimens having a 6.25mm diameter at 4,77, and 295 K and loading rate was 0.5mm/min. Serrations were observed in all alloys at 4 K. The stress-displacement curves at 77 and 4 K showed different tendency from those at 298 K. As the testing temperature decreased, ultimate strengths of 304 and 316 were largely increased compared to the increase of yield strengths, but the increase of ultimate strength of 310S was almost the same to that of yield strength. Type 310S had the highest yield strength and the lowest tensile strength at all temperatutes. These tensile characteristics were considered to be strongly affected by austenite stability.(Author)

  9. Influence of the final temperature of investment healting on the tensile strength and Vickers hardness of CP Ti and Ti-6Al-4V alloy

    Directory of Open Access Journals (Sweden)

    Pedro César Garcia Oliveira

    2007-02-01

    Full Text Available The aim of the work was to evaluate the influence of the temperature of investment healting on the tensile strength and Vickers hardness of CP Ti and Ti-6Al-4V alloy casting. Were obtained for the tensile strength test dumbbell rods that were invested in the Rematitan Plus investment and casting in the Discovery machine cast. Thirty specimens were obtained, fiftten to the CP Titanium and fifteen to the Ti-6Al-4V alloy, five samples to each an of the three temperatures of investment: 430ºC (control group, 480ºC and 530ºC. The tensile test was measured by means of a universal testing machine, MTS model 810, at a strain of 1.0 mm/min. After the tensile strenght test the specimens were secctioned, embedded and polished to hardness measurements, using a Vickers tester, Micromet 2100. The means values to tensile tests to the temperatures 430ºC, 480 and 530: CP Ti (486.1 - 501.16 - 498.14 -mean 495.30 MPa and Ti-6Al-4V alloy (961.33 - 958.26 - 1005.80 - mean 975.13 MPa while for the Vickers hardness the values were (198.06, 197.85, 202.58 - mean 199.50 and (352.95, 339.36, 344.76 - mean 345.69, respectively. The values were submitted to Analysis of Variance (ANOVA and Tukey,s Test that indicate differences significant only between the materials, but not between the temperature, for both the materias. It was conclued that increase of the temperature of investment its not chance the tensile strength and the Vickers hardness of the CP Titanium and Ti-6Al-4V alloy.

  10. Tensile and Torsional Structural Properties of the Native Scapholunate Ligament.

    Science.gov (United States)

    Pang, Eric Quan; Douglass, Nathan; Behn, Anthony; Winterton, Matthew; Rainbow, Michael J; Kamal, Robin N

    2018-02-17

    The ideal material for reconstruction of the scapholunate interosseous ligament (SLIL) should replicate the mechanical properties of the native SLIL to recreate normal kinematics and prevent posttraumatic arthritis. The purpose of our study was to evaluate the cyclic torsional and tensile properties of the native SLIL and load to failure tensile properties of the dorsal SLIL. The SLIL bone complex was resected from 10 fresh-frozen cadavers. The scaphoid and lunate were secured in polymethylmethacrylate and mounted on a test machine that incorporated an x-y stage and universal joint, which permitted translations perpendicular to the rotation/pull axis as well as nonaxial angulations. After a 1 N preload, specimens underwent cyclic torsional testing (±0.45 N m flexion/extension at 0.5 Hz) and tensile testing (1-50 N at 1 Hz) for 500 cycles. Lastly, the dorsal 10 mm of the SLIL was isolated and displaced at 10 mm/min until failure. During intact SLIL cyclic torsional testing, the neutral zone was 29.7° ± 6.6° and the range of rotation 46.6° ± 7.1°. Stiffness in flexion and extension were 0.11 ± 0.02 and 0.12 ± 0.02 N m/deg, respectively. During cyclic tensile testing, the engagement length was 0.2 ± 0.1 mm, the mean stiffness was 276 ± 67 N/mm, and the range of displacement was 0.4 ± 0.1 mm. The dorsal SLIL displayed a 0.3 ± 0.2 mm engagement length, 240 ± 65 N/mm stiffness, peak load of 270 ± 91 N, and displacement at peak load of 1.8 ± 0.3 mm. We report the torsional properties of the SLIL. Our novel test setup allows for free rotation and translation, which reduces out-of-plane force application. This may explain our observation of greater dorsal SLIL load to failure than previous reports. By matching the natural ligament with respect to its tensile and torsional properties, we believe that reconstructions will better restore the natural kinematics of the wrist and lead to improved outcomes. Future clinical studies should aim to investigate this

  11. Mechanical performance of carbon-epoxy laminates. Part II: quasi-static and fatigue tensile properties

    Directory of Open Access Journals (Sweden)

    José Ricardo Tarpani

    2006-06-01

    Full Text Available In Part II of this work, quasi-static tensile properties of four aeronautical grade carbon-epoxy composite laminates, in both the as-received and pre-fatigued states, have been determined and compared. Quasi-static mechanical properties assessed were tensile strength and stiffness, tenacity (toughness at the maximum load and for a 50% load drop-off. In general, as-molded unidirectional cross-ply carbon fiber (tape reinforcements impregnated with either standard or rubber-toughened epoxy resin exhibited the maximum performance. The materials also displayed a significant tenacification (toughening after exposed to cyclic loading, resulting from the increased stress (the so-called wear-in phenomenon and/or strain at the maximum load capacity of the specimens. With no exceptions, two-dimensional woven textile (fabric pre-forms fractured catastrophically under identical cyclic loading conditions imposed to the fiber tape architecture, thus preventing their residual properties from being determined.

  12. On the Da Vinci size effect in tensile strengths of nanowires: A molecular dynamics study

    Science.gov (United States)

    Zhao, Ziyu; Liu, Jinxing; Soh, Ai Kah

    2018-01-01

    In recent decades, size effects caused by grain size, strain gradient, typical defects etc., have been widely investigated. Nevertheless, the dependence of tensile strength on the specimen length, addressed by Da Vinci around 500 hundred years ago, has received rather limited attention, even though it is one unavoidable question to answer if people attempt to bring materials' amazing nano-scale strengths up to macro-level. Therefore, we make efforts to study tensile behaviors of copper nanowires with a common cross-section and various lengths by employing the molecular dynamics simulations. Surprisingly, a strong size effect of Da Vinci type indeed arises. We have shown the influences of lattice orientation, temperature and prescribed notch on such a Da Vinci size effect. Two different theoretical explanations are briefly proposed for a qualitative understanding. Finally, a simple scaling rule is summarized to cover the tendencies observed.

  13. Biomechanical evaluation of a corporectomy in porcine lumbar specimens using flexible polymer belts

    Science.gov (United States)

    Beltrán-Fernández, J. A.; Hernández-Gómez, L. H.; Ruiz-Muñoz, E.; González-Rebattú, A.; Rodríguez-Cañizo, R. G.; Urriolagoitia-Calderón, G.; Urriolagoitia-Sosa, G.; Hernández-Moreno, H.

    2009-08-01

    This paper presents the experimental results of a biomechanical evaluation in lumbar porcine specimens (L2-L4), instrumented with flexible polymer belts, under fatigue and tensile loading. The clinical effect called facetary arthrosis is evaluated. An experimental analysis was carried on 3 lumbar porcine specimens. In two of them, polyamide belts are fixed on the interspinous ligament from L2 to L4. Specimens are taken from pigs which are 6 month old. For the present work, the stiffness reduction of the spine and the biomechanical behaviour of the belts in conjunction with the interspinous ligament are evaluated. The purpose is to determine the failure conditions for the elements of the specimen (vertebral disk, supra and intraspinous ligament and vertebral body). Under static loading, which is the base line case, the elements of the specimen failed as a typical healthy structure. While in the fatigue combined with static loading, the element failed in different order. Additionally, the stiffness changed in accordance with the fatigue loading conditions. Because of the simplicity of this alternative technique, a high level of the structural integrity is preserved, as no holes are made on the spinous process in order to insert the fixation screws. Furthermore, there is a cost reduction.

  14. Biomechanical evaluation of a corporectomy in porcine lumbar specimens using flexible polymer belts

    International Nuclear Information System (INIS)

    Beltran-Fernandez, J A; Hernandez-Gomez, L H; Ruiz-Munoz, E; Urriolagoitia-Calderon, G; Urriolagoitia-Sosa, G; Gonzalez-Rebattu, A; RodrIguez-Canizo, R G; Hernandez-Moreno, H

    2009-01-01

    This paper presents the experimental results of a biomechanical evaluation in lumbar porcine specimens (L2-L4), instrumented with flexible polymer belts, under fatigue and tensile loading. The clinical effect called facetary arthrosis is evaluated. An experimental analysis was carried on 3 lumbar porcine specimens. In two of them, polyamide belts are fixed on the interspinous ligament from L2 to L4. Specimens are taken from pigs which are 6 month old. For the present work, the stiffness reduction of the spine and the biomechanical behaviour of the belts in conjunction with the interspinous ligament are evaluated. The purpose is to determine the failure conditions for the elements of the specimen (vertebral disk, supra and intraspinous ligament and vertebral body). Under static loading, which is the base line case, the elements of the specimen failed as a typical healthy structure. While in the fatigue combined with static loading, the element failed in different order. Additionally, the stiffness changed in accordance with the fatigue loading conditions. Because of the simplicity of this alternative technique, a high level of the structural integrity is preserved, as no holes are made on the spinous process in order to insert the fixation screws. Furthermore, there is a cost reduction.

  15. The validity, reliability, and utility of the iButton® for measurement of body temperature circadian rhythms in sleep/wake research.

    Science.gov (United States)

    Hasselberg, Michael J; McMahon, James; Parker, Kathy

    2013-01-01

    Changes in core body temperature due to heat transfer through the skin have a major influence on sleep regulation. Traditional measures of skin temperature are often complicated by extensive wiring and are not practical for use in normal living conditions. This review describes studies examining the reliability, validity and utility of the iButton®, a wireless peripheral thermometry device, in sleep/wake research. A review was conducted of English language literature on the iButton as a measure of circadian body temperature rhythms associated with the sleep/wake cycle. Seven studies of the iButtton as a measure of human body temperature were included. The iButton was found to be a reliable and valid measure of body temperature. Its application to human skin was shown to be comfortable and tolerable with no significant adverse reactions. Distal skin temperatures were negatively correlated with sleep/wake activity, and the temperature gradient between the distal and proximal skin (DPG) was identified as an accurate physiological correlate of sleep propensity. Methodological issues included site of data logger placement, temperature masking factors, and temperature data analysis. The iButton is an inexpensive, wireless data logger that can be used to obtain a valid measurement of human skin temperature. It is a practical alternative to traditional measures of circadian rhythms in sleep/wake research. Further research is needed to determine the utility of the iButton in vulnerable populations, including those with neurodegenerative disorders and memory impairment and pediatric populations. Copyright © 2011 Elsevier B.V. All rights reserved.

  16. Stress field determination in an alloy 600 stress corrosion crack specimen

    International Nuclear Information System (INIS)

    Rassineux, B.; Labbe, T.

    1995-05-01

    In the context of EDF studies on stress corrosion cracking rates in the Alloy 600 steam generators tubes, we studied the influence of strain hardened surface layers on the different stages of cracking for a tensile smooth specimen (TLT). The stress field was notably assessed to try and explain the slow/rapid-propagation change observed beyond the strain hardened layers. The main difficulty is to simulate in a finite element model the inner and outer surfaces of these strain hardened layers, produced by the final manufacturing stages of SG tubes which have not been heat treated. In the model, the strain hardening is introduced by simulating a multi-layer material. Residual stresses are simulated by an equivalent fictitious thermomechanical calculation, realigned with respect to X-ray measurements. The strain hardening introduction method was validated by an analytical calculation giving identical results. Stress field evolution induced by specimen tensile loading were studied using an elastoplastic 2D finite element calculations performed with the Aster Code. The stress profile obtained after load at 660 MPa shows no stress discontinuity at the boundary between the strain hardened layer and the rest of the tube. So we propose that a complementary calculation be performed, taking into account the multi-cracked state of the strain hardened zones by means of a damage variable. In fact, this state could induce stress redistribution in the un-cracked area, which would perhaps provide an explanation of the crack-ground rate change beyond the strain hardened zone. The calculations also evidence the harmful effects of plastic strains on a strain hardened layer due to the initial state of the tube (not heat-treated), to grit blasting or to shot peening. The initial compressive stress condition of this surface layer becomes, after plastic strain, a tensile stress condition. These results are confirmed by laboratory test. (author). 10 refs., 18 figs., 9 tabs., 2 appends

  17. Tensile and fracture properties of primary heat transport system piping material

    International Nuclear Information System (INIS)

    Singh, P.K.; Chattopadhyay, J.; Kushwaha, H.S.

    1997-07-01

    The fracture mechanics calculations in leak-before-break analysis of nuclear piping system require material tensile data and fracture resistance properties in the form of J-R curve. There are large variations in fracture parameters due to variation in chemical composition and process used in making the steel components. Keeping this in view, a comprehensive program has been planned to generate the material data base for primary heat transport system piping using the specimens machined from actual pipes used in service. The material under study are SA333 Gr.6 (base as well as weld) and SA350 LF2 (base). Since the operating temperatures of 500 MWe Indian PHWR PHT system piping range from 260 degC to 304 degC the test temperature chosen are 28 degC, 200 degC, 250 degC and 300 degC. Tensile and compact tension specimens have been fabricated from actual pipe according to ASTM standard. Fracture toughness of base metal has been observed to be higher compared to weld metal in SA333 Gr.6 material for the temperature under consideration. Fracture toughness has been observed to be higher for LC orientation (notch in circumferential direction) compared to CL orientation (notch is in longitudinal direction) for the temperature range under study. Fracture toughness value decreases with increase in temperature for the materials under study. Finally, chemical analysis has been carried out to investigate the reason for high toughness of the material. It has been concluded that low percentage of carbon and nitrogen, low inclusion rating and fine grain size has enhanced the fracture toughness value

  18. Effect of cryogenic treatment on the tensile behaviour of En 52 and 21-4N valve steels at room and elevated temperatures

    International Nuclear Information System (INIS)

    Jaswin, M. Arockia; Lal, D. Mohan

    2011-01-01

    Research highlights: → Tensile behaviour of cryo-treated valve steels are investigated at elevated temperature. → En 52 and 21-4N valve steel materials are treated at - 196 o C . → Tensile strength of cryo-treated En 52 and 21-4N valve steel has improved by 8 % and 12 % respectively. → Precipitation of fine carbides through cryogenic treatment is the reason for the improved strength. -- Abstract: This experimental study investigates the effects of cryogenic treatment on the tensile behaviour of En 52 and 21-4N valve steels at room and elevated temperatures. The materials are subjected to shallow cryogenic treatment (SCT) at 193 K and deep cryogenic treatment (DCT) at 85 K and the tensile behaviour is compared with that of the conventional heat treatment (CHT). The high temperature tensile test is conducted at 673 K (400 o C) and 923 K (650 o C) for the En 52 and 21-4N valve steels respectively. The ultimate tensile strength of the En 52 and 21-4N DCT samples show an enhancement of 7.87% and 6.76% respectively, over the CHT samples tested at the elevated temperature. The average yield strength of the En 52 DCT samples has an improvement 11% than that of the CHT samples when tested at room and elevated temperatures. The deep cryogenic treatment conducted at the optimized condition shows 7.84% improvement in the tensile strength for the En 52 valve steel and 11.87% improvement for the 21-4N valve steel when compared to the strength of the samples without the cryogenic treatment. A scanning electron microscopic analysis of the fracture surface indicates the presence of dimples and microvoid coalescence on the grain facets and interfaces of the cryo-treated specimens. The fracture surface of the deep cryo-treated 21-4N valve steel specimen shows a complete intergranular fracture with deep secondary cracks between the grains. On comparing the results of the percentage elongation, the cryo-treated samples show a smaller reduction in the elongation than that of the

  19. Voice Based City Panic Button System

    Science.gov (United States)

    Febriansyah; Zainuddin, Zahir; Bachtiar Nappu, M.

    2018-03-01

    The development of voice activated panic button application aims to design faster early notification of hazardous condition in community to the nearest police by using speech as the detector where the current application still applies touch-combination on screen and use coordination of orders from control center then the early notification still takes longer time. The method used in this research was by using voice recognition as the user voice detection and haversine formula for the comparison of closest distance between the user and the police. This research was equipped with auto sms, which sent notification to the victim’s relatives, that was also integrated with Google Maps application (GMaps) as the map to the victim’s location. The results show that voice registration on the application reaches 100%, incident detection using speech recognition while the application is running is 94.67% in average, and the auto sms to the victim relatives reaches 100%.

  20. Microstructure and Tensile Behavior of Al8Co17Cr17Cu8Fe17Ni33 (at.%) High-Entropy Alloy

    Science.gov (United States)

    Daoud, H. M.; Manzoni, A.; Völkl, R.; Wanderka, N.; Glatzel, U.

    2013-12-01

    Microstructure evolution and tensile behavior of the high-entropy alloy Al8Co17Cr17Cu8Fe17Ni33 (at.%) are investigated at room temperature and at 500°C in the as-cast state and under different heat-treatment conditions. Detailed microstructural characterizations are carried out using optical microscopy, scanning electron microscopy, and transmission electron microscopy. The equilibrium phase evolution as a function of temperature was calculated using the Thermo-Calc software (Thermo-Calc Software, Stockholm, Sweden) integrated with TTNi-7 database. The observed majority phase is a face-centered cubic solid solution for all tested specimens. Tensile ductility at room temperature and at elevated temperature is enhanced by heat treatment at 1150°C. An embrittlement phenomenon has been observed after a heat treatment at 700°C resulting in significant degradation in tensile properties.

  1. EL PATAGONISMO COMO CONSTRUCCIÓN DISCURSIVA Y LA GÉNESIS DE UN PERSONAJE LITERARIO: JEMMY BUTTON / PATAGONISM AS DISCURSIVE CONSTRUCTION AND THE GENESIS OF A LITERARY CHARACTER: JEMMY BUTTON

    Directory of Open Access Journals (Sweden)

    Elda Patricia Moller Jensen

    2016-06-01

    Full Text Available A partir de la detección de un discurso eurocentrista aún presente en el libro álbum Jemmy Button y de la novela histórica Three Men of the Beagle, dos obras anglófonas contemporáneas sobre Tierra del Fuego, en las cuales se evidencia la presencia de los estereotipos del británico civilizador y del salvaje caníbal de Tierra del Fuego, este artículo se propone explorar el proceso de construcción discursiva en un intento por detectar cómo, cuándo y dónde surgieron los mencionados estereotipos. En las narrativas de los exploradores británicos que visitaron la Patagonia en el siglo XIX, en lo que Pratt denomina zona de contacto, se observa con claridad este proceso de construcción discursiva de los estereotipos fundacionales de la literatura anglófona sobre Tierra del Fuego. Tal construcción, en analogía con lo que Said denomina orientalismo, puede denominarse patagonismo, ya que define al otro según la ideología del imperio y utiliza como recursos descriptivos las categorías del salvaje caníbal y del británico civilizador. Tomando como estudio de caso los relatos sobre Orundellico, llamado Jemmy Button por los británicos, cotejando estos relatos con datos históricos, e interpretando la voz del colonizador y la falta de voz del colonizado, no sólo se identifica el caso de Jemmy Button como uno de los casos más interesantes de resistencia lingüística y cultural. También permite una exploración sobre la manera en que esta herramienta identificadora del discurso británico sobre la Patagonia se ha fortalecido creando un personaje de ficción que aun hoy habita los textos literarios que relatan las historias de aquella época. / After the analysis of two contemporary Anglophone narratives construed around the story of Orundellico, known to the British as Jemmy Button, the picturebook Jemmy Button and the historical novel Three Men of the Beagle (Marks, 1991, it becomes evident that both still make use of a Eurocentric

  2. Predicting the tensile strength of A UD basalt/ epoxy composite used for the confinement of concrete structures

    Science.gov (United States)

    Ciniņa, I.; Zīle, O.; Andersons, J.

    2013-01-01

    The principal aim of the present research was to predict the strength of UD basalt fiber/epoxy matrix composites in tension along the reinforcement direction. Tension tests on single basalt fibers were performed to determine the functional form of their strength distribution and to evaluate the parameters of the distribution. Also, microbond tests were carried out to assess the interfacial shear strength of the fibers and polymer matrix. UD composite specimens were produced and tested for the longitudinal tensile strength. The predicted strength of the composite was found to exceed the experimental values by ca. 20%, which can be explained by imperfections in the fiber alignment, impregnation, and adhesion in the composite specimens.

  3. Effect of curing and silanizing on composite repair bond strength using an improved micro-tensile test method.

    Science.gov (United States)

    Eliasson, Sigfus Thor; Dahl, Jon E

    2017-01-01

    Objectives: To evaluate the micro-tensile repair bond strength between aged and new composite, using silane and adhesives that were cured or left uncured when new composite was placed. Methods: Eighty Filtek Supreme XLT composite blocks and four control blocks were stored in water for two weeks and thermo-cycled. Sandpaper ground, etched and rinsed specimens were divided into two experimental groups: A, no further treatment and B, the surface was coated with bis-silane. Each group was divided into subgroups: (1) Adper Scotchbond Multi-Purpose, (2) Adper Scotchbond Multi-Purpose adhesive, (3) Adper Scotchbond Universal, (4) Clearfil SE Bond and (5) One Step Plus. For each adhesive group, the adhesive was (a) cured according to manufacturer's instructions or (b) not cured before repair. The substrate blocks were repaired with Filtek Supreme XLT. After aging, they were serially sectioned, producing 1.1 × 1.1 mm square test rods. The rods were prepared for tensile testing and tensile strength calculated at fracture. Type of fracture was examined under microscope. Results: Leaving the adhesive uncured prior to composite repair placement increased the mean tensile values statistically significant for all adhesives tested, with or without silane pretreatment. Silane surface treatment improved significantly ( p strength values for all adhesives, both for the cured and uncured groups. The mean strength of the control composite was higher than the strongest repair strength ( p strength. Not curing the adhesive before composite placement increased the tensile bond strength.

  4. The effect of strain rate and temperature on the tensile behaviour of uranium 2 w/o molybdenum

    International Nuclear Information System (INIS)

    Harding, J.; Boyd, G.A.C.

    1983-01-01

    This report describes the uniaxial tensile behaviour of uranium 2 w/o molybdenum alloy over a wide range of temperature and strain rate. Specimen blanks taken from co-reduced and extruded U 2 w/o Mo rods were given one of two heat treatments. Longitudinal tensile test pieces, taken from these blanks at near surface locations were tested in the temperature range -150 deg C to +100 deg C at strain rates from quasistatic (10 -4 s -1 ) to 10 3 s -1 . To achieve this range of testing rates three machines were required: an Instron screw driven machine for rates up to 0.1 s -1 , a second specially constructed hydraulic machine for the range 0.1 s -1 to 50 s -1 and a drop weight machine for the highest strain rates. The ways in which the mechanical properties - elongation to fracture, flow stresses and ultimate tensile stress - vary with both temperature and strain rate are presented and discussed for material in both heat treatment conditions. (author)

  5. Tensile behavior of RAFM alloys after neutron irradiation of up to 16.3 dpa between 250 and 450 °C

    International Nuclear Information System (INIS)

    Materna-Morris, E.; Schneider, H.-C.; Möslang, A.

    2014-01-01

    Tensile specimen of steel EUROFER97 and other alloys on the basis of RAFM steels such, as OPTIFER and F82H alloys, and Ga3X were irradiated and post-examined during a neutron irradiation program of up to 16.3 dpa between 250 and 450 °C in the HFR (High Flux Reactor) in the Netherlands. These tensile results were compared with former irradiation programs, with lower neutron doses of up to 0.8 and 2.4 dpa to quantify the difference in tensile strengthening. The average increase of tensile strength was in a range of 300 MPa between 0.8 and 16.3 dpa at temperatures of 250–300 °C. This behavior can be correlated with irradiation-induced changes in the microstructure. Most of the hardening can be attributed to dislocation loops, point defects or small precipitates as observed in boron-free alloys as F82H mod. and EUROFER97. Whereas the hardening in boron-containing alloys OPTIFER alloys and Ga3X can be correlated in addition with the combination of helium bubbles. At the highest irradiation and test temperature at 450 °C, all tensile data of all investigated materials were in the range of those of non-irradiated and irradiated material due to thermal aging effects

  6. Tensile behavior of RAFM alloys after neutron irradiation of up to 16.3 dpa between 250 and 450 °C

    Energy Technology Data Exchange (ETDEWEB)

    Materna-Morris, E., E-mail: edeltraud.materna-morris@kit.edu; Schneider, H.-C., E-mail: hans-christian.schneider@kit.edu; Möslang, A., E-mail: anton.moeslang@kit.edu

    2014-12-15

    Tensile specimen of steel EUROFER97 and other alloys on the basis of RAFM steels such, as OPTIFER and F82H alloys, and Ga3X were irradiated and post-examined during a neutron irradiation program of up to 16.3 dpa between 250 and 450 °C in the HFR (High Flux Reactor) in the Netherlands. These tensile results were compared with former irradiation programs, with lower neutron doses of up to 0.8 and 2.4 dpa to quantify the difference in tensile strengthening. The average increase of tensile strength was in a range of 300 MPa between 0.8 and 16.3 dpa at temperatures of 250–300 °C. This behavior can be correlated with irradiation-induced changes in the microstructure. Most of the hardening can be attributed to dislocation loops, point defects or small precipitates as observed in boron-free alloys as F82H mod. and EUROFER97. Whereas the hardening in boron-containing alloys OPTIFER alloys and Ga3X can be correlated in addition with the combination of helium bubbles. At the highest irradiation and test temperature at 450 °C, all tensile data of all investigated materials were in the range of those of non-irradiated and irradiated material due to thermal aging effects.

  7. Experimental Investigations on the effect of Additive on the Tensile Properties of Fiber Glass Fabric Lamina

    Science.gov (United States)

    Nava Sai Divya, A.; Raghu Kumar, B., Dr; Lakshmi Narayana, G., Dr

    2017-09-01

    The main objective of this work is to investigate the effect of additives on tensile behaviour of fiber glass fabric at lamina level to explore an alternative skin material for the outer body of aerospace applications and machines. This experimental work investigates the effect of silica concentration in epoxy resin lapox L-12 on the tensile properties of glass fabric lamina of 4H-satin weave having 3.6 mm thickness. The lamina was prepared by using hand lay-up method and tests were conducted on it. Various tensile properties values obtained from experimentation were compared for four glass fiber lamina composites fabricated by adding the silica powder to resin bath. The effect of variations in silica concentration (0% SiO2, 5% SiO2, 10% SiO2 and 15% SiO2) on the tensile properties of prepared material revealed that maximum stiffness was obtained at 15% and yield strength at 10% SiO2 concentration in glass fiber lamina. Increasing the silica concentration beyond 10% had led to deterioration in the material properties. The experimentation that was carried out on test specimen was reasonably successful as the effect of silica powder as an additive in glass fiber lamina enhanced the mechanical properties up to certain limit. The underpinning microscopic behaviour at the source of these observations will be investigated in a follow up work.

  8. Coherent Raman Scattering Microscopy for Evaluation of Head and Neck Carcinoma.

    Science.gov (United States)

    Hoesli, Rebecca C; Orringer, Daniel A; McHugh, Jonathan B; Spector, Matthew E

    2017-09-01

    Objective We aim to describe a novel, label-free, real-time imaging technique, coherent Raman scattering (CRS) microscopy, for histopathological evaluation of head and neck cancer. We evaluated the ability of CRS microscopy to delineate between tumor and nonneoplastic tissue in tissue samples from patients with head and neck cancer. Study Design Prospective case series. Setting Tertiary care medical center. Subjects and Methods Patients eligible were surgical candidates with biopsy-proven, previously untreated head and neck carcinoma and were consented preoperatively for participation in this study. Tissue was collected from 50 patients, and after confirmation of tumor and normal specimens by hematoxylin and eosin (H&E), there were 42 tumor samples and 42 normal adjacent controls. Results There were 42 confirmed carcinoma specimens on H&E, and CRS microscopy identified 37 as carcinoma. Of the 42 normal specimens, CRS microscopy identified 40 as normal. This resulted in a sensitivity of 88.1% and specificity of 95.2% in distinguishing between neoplastic and nonneoplastic images. Conclusion CRS microscopy is a unique label-free imaging technique that can provide rapid, high-resolution images and can accurately determine the presence of head and neck carcinoma. This holds potential for implementation into standard practice, allowing frozen margin evaluation even at institutions without a histopathology laboratory.

  9. The effect of a single tensile overload on stress corrosion cracking growth of stainless steel in a light water reactor environment

    International Nuclear Information System (INIS)

    Xue He; Li Zhijun; Lu Zhanpeng; Shoji, Tetsuo

    2011-01-01

    Research highlights: → The affect of a single tensile overload on SCC growth rate is investigated. → A single tensile overload would produce a residual plastic strain in the SCC tip. → The residual plastic strain would decrease the plastic strain rate in the SCC tip. → A single tensile overload would cause crack growth rate retardation in the SCC tip. → SCC growth rate in the quasi-stationary crack tip is relatively lower. - Abstract: It has been found that a single tensile overload applied during constant load amplitude might cause crack growth rate retardation in various crack propagating experiments which include fatigue test and stress corrosion cracking (SCC) test. To understand the affecting mechanism of a single tensile overload on SCC growth rate of stainless steel or nickel base alloy in light water reactor environment, based on elastic-plastic finite element method (EPFEM), the residual plastic strain in both tips of stationary and growing crack of contoured double cantilever beam (CDCB) specimen was simulated and analyzed in this study. The results of this investigation demonstrate that a residual plastic strain in the region immediately ahead of the crack tips will be produced when a single tensile overload is applied, and the residual plastic strain will decrease the plastic strain rate level in the growing crack tip, which will causes crack growth rate retardation in the tip of SCC.

  10. Residual Tensile Strength and Bond Properties of GFRP Bars after Exposure to Elevated Temperatures

    Directory of Open Access Journals (Sweden)

    Devon S. Ellis

    2018-02-01

    Full Text Available The use of fiber reinforced polymer (FRP bars in reinforced concrete members enhances corrosion resistance when compared to traditional steel reinforcing bars. Although there is ample research available on the behavior of FRP bars and concrete members reinforced with FRP bars under elevated temperatures (due to fire, there is little published information available on their post-fire residual load capacity. This paper reports residual tensile strength, modulus of elasticity, and bond strength (to concrete of glass fiber reinforced polymer (GFRP bars after exposure to elevated temperatures of up to 400 °C and subsequent cooling to an ambient temperature. The results showed that the residual strength generally decreases with increasing temperature exposure. However, as much as 83% of the original tensile strength and 27% of the original bond strength was retained after the specimens were heated to 400 °C and then cooled to ambient temperature. The residual bond strength is a critical parameter in post-fire strength assessments of GFRP-reinforced concrete members.

  11. Residual Tensile Strength and Bond Properties of GFRP Bars after Exposure to Elevated Temperatures.

    Science.gov (United States)

    Ellis, Devon S; Tabatabai, Habib; Nabizadeh, Azam

    2018-02-27

    The use of fiber reinforced polymer (FRP) bars in reinforced concrete members enhances corrosion resistance when compared to traditional steel reinforcing bars. Although there is ample research available on the behavior of FRP bars and concrete members reinforced with FRP bars under elevated temperatures (due to fire), there is little published information available on their post-fire residual load capacity. This paper reports residual tensile strength, modulus of elasticity, and bond strength (to concrete) of glass fiber reinforced polymer (GFRP) bars after exposure to elevated temperatures of up to 400 °C and subsequent cooling to an ambient temperature. The results showed that the residual strength generally decreases with increasing temperature exposure. However, as much as 83% of the original tensile strength and 27% of the original bond strength was retained after the specimens were heated to 400 °C and then cooled to ambient temperature. The residual bond strength is a critical parameter in post-fire strength assessments of GFRP-reinforced concrete members.

  12. Tensile and Compressive Properties of Woven Kenaf/Glass Sandwich Hybrid Composites

    Directory of Open Access Journals (Sweden)

    Mohaiman J. Sharba

    2016-01-01

    Full Text Available Monotonic (tensile and compression properties of woven kenaf/glass reinforced unsaturated polyester sandwich hybrid composites have been experimentally investigated. Five types of composites laminates were fabricated using a combination of hand lay-up and cold press techniques, postcured for two hours at 80°C and left for 48 hours at room temperature. The hybrid composites contained fixed six layers of glass as a shell, three on each side, whereas the number of core kenaf layers was changed in three stages to get S1, S2, and S3 hybrid composites. Composites specimens with pure glass and kenaf were also fabricated for comparison. It was found that one kenaf layer replaced about 20% of total fiber weight fraction of the composite; this leads to reducing the density of final hybrid composite by 13%. Besides, in mechanical properties perspective, there are less than 1% reduction in compression strength and 40% in tensile strength when compared to pure glass composite. Generally, the results revealed that the best performance was observed in S1, which showed a good balance of all mechanical properties determined in this work.

  13. Role of age and injury mechanism on cervical spine injury tolerance from head contact loading.

    Science.gov (United States)

    Yoganandan, Narayan; Chirvi, Sajal; Voo, Liming; Pintar, Frank A; Banerjee, Anjishnu

    2018-02-17

    The objective of this study was to determine the influence of age and injury mechanism on cervical spine tolerance to injury from head contact loading using survival analysis. This study analyzed data from previously conducted experiments using post mortem human subjects (PMHS). Group A tests used the upright intact head-cervical column experimental model. The inferior end of the specimen was fixed, the head was balanced by a mechanical system, and natural lordosis was removed. Specimens were placed on a testing device via a load cell. The piston applied loading at the vertex region. Spinal injuries were identified using medical images. Group B tests used the inverted head-cervical column experimental model. In one study, head-T1 specimens were fixed distally, and C7-T1 joints were oriented anteriorly, preserving lordosis. Torso mass of 16 kg was added to the specimen. In another inverted head-cervical column study, occiput-T2 columns were obtained, an artificial head was attached, T1-T2 was fixed, C4-C5 disc was maintained horizontal in the lordosis posture, and C7-T1 was unconstrained. The specimens were attached to the drop test carriage carrying a torso mass of 15 kg. A load cell at the inferior end measured neck loads in both studies. Axial neck force and age were used as the primary response variable and covariate to derive injury probability curves using survival analysis. Group A tests showed that age is a significant (P < .05) and negative covariate; that is, increasing age resulted in decreasing force for the same risk. Injuries were mainly vertebral body fractures and concentrated at one level, mid-to-lower cervical spine, and were attributed to compression-related mechanisms. However, age was not a significant covariate for the combined data from group B tests. Both group B tests produced many soft tissue injuries, at all levels, from C1 to T1. The injury mechanism was attributed to mainly extension. Multiple and noncontiguous injuries occurred

  14. Experimental assessments of notch ductility and tensile strength of stainless steel weldments after 1200C neutron irradiation

    International Nuclear Information System (INIS)

    Hawthorne, J.R.; Menke, B.H.; Awadalla, N.G.; O'Kula, K.R.

    1986-01-01

    The Charpy-V (C/sub v/) properties of AISI 300 series stainless steel plate, weld, and weld heat-affected zone (HAZ) materials from commercial production weldments in 406-mm-diameter pipe (12.7-mm wall) were investigated in unirradiated and irradiated conditions. Weld and HAZ tensile properties were also assessed in the two conditions. The plates and weld filler wires represent different steel melts; the welds were produced using the multipass MIG process. Weldment properties in two test orientations were evaluated. Specimens were irradiated in the UBR reactor to 1 x 10 20 n/cm 2 , E >0.1 MeV in a controlled temperature assembly. Specimen tests were performed at 25 0 C and 125 0 C. The radiation-induced reductions in C/sub v/ energy absorption at 25 0 C were about 42 percent for the weld and HAZ materials evaluated. A trend of energy increase with temperature was observed. The concomitant elevation in yield strength was about 53%. In contrast, the increase in tensile strength was only 16%. The postirradiation yield strength of the axial test orientation in the pipe was less than that of the circumferential test orientation. Results for the HAZ indicate that this component may be the weakest link in the weldment from a fracture resistant viewpoint

  15. Aluminum-thin-film packaged fiber Bragg grating probes for monitoring the maximum tensile strain of composite materials.

    Science.gov (United States)

    Im, Jooeun; Kim, Mihyun; Choi, Ki-Sun; Hwang, Tae-Kyung; Kwon, Il-Bum

    2014-06-10

    In this paper, new fiber Bragg grating (FBG) sensor probes are designed to intermittently detect the maximum tensile strain of composite materials, so as to evaluate the structural health status. This probe is fabricated by two thin Al films bonded to an FBG optical fiber and two supporting brackets, which are fixed on the surface of composite materials. The residual strain of the Al packaged FBG sensor probe is induced by the strain of composite materials. This residual strain can indicate the maximum strain of composite materials. Two types of sensor probes are prepared-one is an FBG with 18 μm thick Al films, and the other is an FBG with 36 μm thick Al films-to compare the thickness effect on the detection sensitivity. These sensor probes are bonded on the surfaces of carbon fiber reinforced plastics composite specimens. In order to determine the strain sensitivity between the residual strain of the FBG sensor probe and the maximum strain of the composite specimen, tensile tests are performed by universal testing machine, under the loading-unloading test condition. The strain sensitivities of the probes, which have the Al thicknesses of 18 and 36 μm, are determined as 0.13 and 0.23, respectively.

  16. Experimental and numerical analysis concerning the behaviour of OL50 steel grade specimens coated with polyurea layer under dynamics loadings

    Directory of Open Access Journals (Sweden)

    Bucur Florina

    2015-01-01

    Full Text Available This study refers to an experimental and numerical evaluation of a polyurea coating layer influence on the dynamic behaviour of OL50 specimens. Mechanical quasi-static and dynamic tensile tests were performed in axial loading conditions, for 2 mm steel plate specimens. Several metallic specimens have been previously coated with 1.5 mm and 3 mm respectively thickness polyurea layer and tested in traction. The findings results indicate that the presence of polyurea changes the loading pattern of metallic material in the necking area. In terms of polyurea coated metal specimens fracture, there was clearly observed a change of fracture limit. One possible explanation of this phenomenon is the modification of triaxiality state in the necking zone, fact proven by the numerical simulations. Test results indicate that the presence of polyurea layer delays the necking onset phenomenon which precedes the OL50 metallic specimen fracture.

  17. On the Da Vinci size effect in tensile strengths of nanowires: A molecular dynamics study

    Directory of Open Access Journals (Sweden)

    Ziyu Zhao

    2018-01-01

    Full Text Available In recent decades, size effects caused by grain size, strain gradient, typical defects etc., have been widely investigated. Nevertheless, the dependence of tensile strength on the specimen length, addressed by Da Vinci around 500 hundred years ago, has received rather limited attention, even though it is one unavoidable question to answer if people attempt to bring materials’ amazing nano-scale strengths up to macro-level. Therefore, we make efforts to study tensile behaviors of copper nanowires with a common cross-section and various lengths by employing the molecular dynamics simulations. Surprisingly, a strong size effect of Da Vinci type indeed arises. We have shown the influences of lattice orientation, temperature and prescribed notch on such a Da Vinci size effect. Two different theoretical explanations are briefly proposed for a qualitative understanding. Finally, a simple scaling rule is summarized to cover the tendencies observed.

  18. The color changes and tensile properties of oxidized Ti–6A1–2Mo–1.5Cr–2Zr–2Sn–2Nb alloy

    Energy Technology Data Exchange (ETDEWEB)

    Jia, Zhiqiang, E-mail: jzq19841102@gmail.com [State Key Laboratory of Solidification Processing, Northwestern Polytechnical University, Xi’an 710072 (China); Zeng, Weidong, E-mail: zengwd@nwpu.edu.cn [State Key Laboratory of Solidification Processing, Northwestern Polytechnical University, Xi’an 710072 (China); Zhang, Yaowu [State Key Laboratory of Solidification Processing, Northwestern Polytechnical University, Xi’an 710072 (China); Shi, Chunling [Xi’an Aircraft Industry Company LTD, 710089 (China); Quan, Biao; Wu, Jianding [State Key Laboratory of Solidification Processing, Northwestern Polytechnical University, Xi’an 710072 (China)

    2015-08-15

    Highlights: • The oxidized alloy exhibited notable color changes. • The color was mainly attributed to the mixing of titanium oxides. • A corresponding relation between the color and tensile properties was established. • A predicted model was proposed to characterize the diffusion of oxygen. - Abstract: The oxidation of titanium alloy at elevated temperature severely limits its property and service life. It is a common and urgent issue to assess the mechanical property of oxidized titanium component without destroying its structural integrity. In this work, the color changes and tensile properties of oxidized Ti–6A1–2Mo–1.5Cr–2Zr–2Sn–2Nb alloy with initial basket-weave microstructure were investigated in the temperature range of 100–1000 °C. It was found that the oxidized specimens exhibited brilliant and regular color changes. X-ray diffraction (XRD) analysis indicated that the color changes were mainly attributed to the mixing of colored titanium oxides in the oxidation layer (such as yellow TiO, white TiO{sub 2} and blue Ti{sub 2}O{sub 3}). It was also found that mechanical properties were significant influenced by the oxidation treatment. The specimens oxidized below 600 °C exhibited excellent strength and plasticity due to its fine basket-weave microstructure and dense oxidation layer. In the temperature range from 600 to 800 °C, the strength slightly decreased while the plasticity rose a little. The change of mechanical properties during the temperature range was mainly determined by the microstructure change. Eventually, both strength and plasticity decreased sharply when the temperature was over 800 °C, which was mainly caused by the thick oxidation layer with porous and loose microstructure. The fracture mode of tensile specimens also changed from ductile fracture (below 800 °C) to transgranular cleavage fracture (over 800 °C). On the basis of experiments, a corresponding relation between the color changes and tensile properties

  19. Axial and transverse tensile properties Zr-2.5Nb pressure tube off-cuts

    International Nuclear Information System (INIS)

    Shah, Priti K.; Dubey, J.S.; Shriwastaw, R.S.; Balakrishnan, K.S.; Anantharaman, S.; Chakravartty, J.K.

    2011-01-01

    Zr-2.5Nb alloys in cold worked and stress relieved (CWSR) condition serves as pressure boundary for hot coolant in Indian Pressurized Heavy Water Reactor (IPHWR). Due to both microstructural and crystallographic anisotropy, the mechanical properties in general and fracture behavior in particular are anisotropic for this material. To understand the anisotropic mechanical behavior of the Zr-2.5Nb pressure tubes of IPHWRs, tension tests were carried out on the RAPS-2 and KAPS-2 pressure tube off-cuts. Off-cuts are the small pieces cut from the two ends of a pressure tube before installing it into the PHWR. Miniature flat tensile specimens (without applying any flattening treatment to the pressure tube) of both longitudinal (or axial) and transverse orientation were fabricated from the off-cuts. Tension tests were carried out both at room temperature and 300 deg C. The transverse specimens showed higher strength and lower elongation than that of the axial ones. The back-end off-cuts showed higher strength compared to front-end off-cuts along axial direction whereas the same is not true for transverse direction specimens. One typical plot obtained in the testing of one of the off-cut is shown. The paper will discuss about the importance of the work carried out, test specimens, test method and results obtained in detail

  20. Insertion of balloon retained gastrostomy buttons: a 5-year retrospective review of 260 patients.

    LENUS (Irish Health Repository)

    Power, Sarah

    2013-04-01

    Radiologically inserted gastrostomy (RIG) is an established way of maintaining enteral nutrition in patients who cannot maintain nutrition orally. The purpose of this study was to evaluate the safety and efficacy of primary placement of a wide bore button gastrostomy in a large, varied patient population through retrospective review.

  1. Section thickness-dependent tensile properties of squeeze cast magnesium alloy AM60

    Directory of Open Access Journals (Sweden)

    Xuezhi Zhang

    2012-05-01

    Full Text Available The development of alternative casting processes is essential for the high demand of light weight magnesium components to be used in the automotive industry, which often contain different section thicknesses. Squeeze casting with its inherent advantages has been approved for the capability of minimizing the gas porosity in magnesium alloys. For advanced engineering design of light magnesium automotive applications, it is critical to understand the effect of section thickness on mechanical properties of squeeze cast magnesium alloys. In this study, magnesium alloy AM60 with different section thicknesses of 6, 10 and 20 mm squeeze cast under an applied pressure of 30 MPa was investigated. The prepared squeeze cast AM60 specimens were tensile tested at room termperature. The results indicate that the mechanical properties including yield strength (YS, ultimate tensile strength (UTS and elongation (A decrease with an increase in section thickness of squeeze cast AM60. The microstructure analysis shows that the improvement in the tensile behavior of squeeze cast AM60 is primarily attributed to the low-gas porosity level and fine grain strucuture which result from the variation of cooling rate of different section thickness. The numerical simulation (Magmasoft? was employed to determine the solidification rates of each step, and the simulated results show that the solidification rate of the alloy decreases with an increase in the section thickness. The computed solidification rates support the experimental observation on grain structural development.

  2. Flexural and diametral tensile strength of composite resins

    Directory of Open Access Journals (Sweden)

    Álvaro Della Bona

    2008-03-01

    Full Text Available This study evaluated the flexural strength (sf and the diametral tensile strength (st of light-cured composite resins, testing the hypothesis that there is a positive relation between these properties. Twenty specimens were fabricated for each material (Filtek Z250- 3M-Espe; AM- Amelogen, Ultradent; VE- Vit-l-escence, Ultradent; EX- Esthet-X, Dentsply/Caulk, following ISO 4049 and ANSI/ADA 27 specifications and the manufacturers’ instructions. For the st test, cylindrical shaped (4 mm x 6 mm specimens (n = 10 were placed with their long axes perpendicular to the applied compressive load at a crosshead speed of 1.0 mm/min. The sf was measured using the 3-point bending test, in which bar shaped specimens (n = 10 were tested at a crosshead speed of 0.5 mm/min. Both tests were performed in a universal testing machine (EMIC 2000 recording the fracture load (N. Strength values (MPa were calculated and statistically analyzed by ANOVA and Tukey (a = 0.05. The mean and standard deviation values (MPa were Z250-45.06 ± 5.7; AM-35.61 ± 5.4; VE-34.45 ± 7.8; and EX-42.87 ± 6.6 for st; and Z250-126.52 ± 3.3; AM-87.75 ± 3.8; VE-104.66 ± 4.4; and EX-119.48 ± 2.1 for sf. EX and Z250 showed higher st and sf values than the other materials evaluated (p < 0.05, which followed a decreasing trend of mean values. The results confirmed the study hypothesis, showing a positive relation between the material properties examined.

  3. Laser-induced generation of pure tensile stresses

    International Nuclear Information System (INIS)

    Niemz, M.H.; Lin, C.P.; Pitsillides, C.; Cui, J.; Doukas, A.G.; Deutsch, T.F.

    1997-01-01

    While short compressive stresses can readily be produced by laser ablation, the generation of pure tensile stresses is more difficult. We demonstrate that a 90 degree prism made of polyethylene can serve to produce short and pure tensile stresses. A compressive wave is generated by ablating a thin layer of strongly absorbing ink on one surface of the prism with a Q-switched frequency-doubled Nd:YAG laser. The compressive wave driven into the prism is reflected as a tensile wave by the polyethylene-air interface at its long surface. The low acoustic impedance of polyethylene makes it ideal for coupling tensile stresses into liquids. In water, tensile stresses up to -200bars with a rise time of the order of 20 ns and a duration of 100 ns are achieved. The tensile strength of water is determined for pure tensile stresses lasting for 100 ns only. The technique has potential application in studying the initiation of cavitation in liquids and in comparing the effect of compressive and tensile stress transients on biological media. copyright 1997 American Institute of Physics

  4. Cracking and Failure in Rock Specimen Containing Combined Flaw and Hole under Uniaxial Compression

    Directory of Open Access Journals (Sweden)

    Xiang Fan

    2018-01-01

    Full Text Available Flaw is a key factor influencing failure behavior of a fractured specimen. In the present study, rectangular-flawed specimens were prepared using sandstone to investigate the effect of flaw on failure behavior of rock. Open flaw and cylindrical hole were simultaneously precut within rock specimens using high-pressure water jet cutting technology. Five series of specimens including intact, single-hole-alone, two-hole-alone, single-hole and two-flaw, and two-hole and single-flaw blocks were prepared. Uniaxial compressive tests using a rigid servo control instrument were carried out to investigate the fracture processes of these flawed specimens. It is observed that during loading, internal stress always intensively distributed at both sidewalls of open hole, especially at midpoint of sidewalls, so rock crumb flaking was firstly observed among all sandstone specimens containing single hole or two holes. Cracking around open hole is associated with the flaw inclination angle which was observed in Series III and V. Crack easily initiated at the tips of flaw with inclination angles of 0°, 30°, and 60° but hard for 90° in Series III and V. Rock burst was the major failure mode among most tested specimens, which generally induced new cracks and finally created crater shape. Additionally, due to extrusion between blocks, new shear or tensile cracks were generated and the rock specimen surface spalled. Eventually, four typical failure processes including rock crumb flaking, crack initiation and propagation, rock burst, and second rupture, were summarized.

  5. Two new tensile devices for X-ray diffraction experiments

    Energy Technology Data Exchange (ETDEWEB)

    Freri, N.; Tintori, A.; Depero, L.E.; Sangaletti, L. [Brescia Univ. (Italy); Cernuschi, F.; Ghia, S. [Ente Nazionale per l`Energia Elettrica, Milan (Italy)

    1995-12-01

    Two tensile devices were designed to be used with parallel beam and parafocusing-geometry diffractometers. In thefirst case the device was designed to be attached to a strainflex diffractometer by Rigaku Inc., dedicated to stress analysis and commonly used in metallurgical industry. Since the sample does not move during the measurement, the tensile device can be kept fixed on the experimental table. The device design takes into account the steric hindrance by moving parts of diffractometer. The maximun load that can be applied to the sample is 60.000 N. An attachement to a Siemens D5000 diffractometer with Eulerian cradle has also benn designed for applying a load up tp 6000 N to a sample in the parafocusing-geometry. The installation does not require a re-alignment of the diffractometer. In both cases strain gages were applied to both sides of the specimen for the simultaneous determination of the macroscopic strains. Experiments based on the use of these devices are planned to determine the crystallographic elastic constants and study the influence of the microstructure on the mechanical behaviour of residual stresses in the zone of almost static stresses as well as the influence of residual stresses on uniaxially loaded samples. In addition, by using these devices, it is possible to measure the unstressed d-0 spacings providing useful information in the neutron diffraction study fo stress fields in steel samples.

  6. Effect of strain rate and stress triaxiality on tensile behavior of Titanium alloy Ti-10-2-3 at elevated temperatures

    Energy Technology Data Exchange (ETDEWEB)

    Bobbili, Ravindranadh, E-mail: ravindranadh@dmrl.drdo.in; Madhu, Vemuri

    2016-06-14

    In this study, Split hopkinson tension bar (SHTB) has been employed to investigate the dynamic tensile flow behavior of Ti-10-2-3 alloy at high strain rates and elevated temperatures. The combined effect of stress triaxiality, strain rate and temperature and on the tensile behavior of the alloy was evaluated. Johnson-Cook (J-C) constitutive and fracture models were developed based on high strain rate tensile data. A modified Johnson–Cook model was established and proved to have high accuracy. A comparative assessment has been done to confirm the accuracy of modified J–C model based on finite element method (FEM). The improved model provides better description on the influence of equivalent plastic strain rate and temperature on the plastic flow. The simulation results proved to be in good agreement with the experimental data. The fracture surfaces of specimens tested under various strain rates and temperatures were studied under scanning electron microscopy (SEM).

  7. The effect of strain rate and temperature on the tensile behaviour of uranium - 2sup(w)/o molybdenum

    International Nuclear Information System (INIS)

    Harding, J.; Boyd, G.A.C.

    1983-01-01

    This report describes the uniaxial tensile behaviour of uranium 2 w/o molybdenum alloy over a wide range of temperature and strain rate. Specimen blanks taken from co-reduced and extruded U2 w/o Mo rods were given one of two heat treatments. Longitudinal tensile test pieces, taken from these blanks at near surface locations were tested in the temperature range -150 deg C to +100 deg C at strain rates from quasistatic (10 -4 s -1 ) to 10 3 s -1 . To achieve this range of testing rates three machines were required: an Instron screw driven machine for rates up to 0.1 s -1 , a second specially constructed hydraulic machine for the range 0.1 s -1 to 50 s -1 and a drop weight machine for the highest strain rates. The ways in which the mechanical properties - elongation to fracture, flow stresses and ultimate tensile stress - vary with both temperature and strain rate are presented and discussed for material in both heat treatment conditions. (author)

  8. 78 FR 33419 - Announcement of Requirements and Registration for “Blue Button Co-Design Challenge”

    Science.gov (United States)

    2013-06-04

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES Announcement of Requirements and Registration for ``Blue Button Co-Design Challenge'' AGENCY: Office of the National Coordinator for Health Information Technology... Electronic Health Record into another product or holding place of their choice. This is an enormous...

  9. The usefulness of 3D quantitative analysis with using MRI for measuring osteonecrosis of the femoral head

    International Nuclear Information System (INIS)

    Hwang, Ji Young; Lee, Sun Wha; Park, Youn Soo

    2006-01-01

    We wanted to evaluate the usefulness of MRI 3D quantitative analysis for measuring osteonecrosis of the femoral head in comparison with MRI 2D quantitative analysis and quantitative analysis of the specimen. For 3 months at our hospital, 14 femoral head specimens with osteonecrosis were obtained after total hip arthroplasty. The patients preoperative MRIs were retrospectively reviewed for quantitative analysis of the size of the necrosis. Each necrotic fraction of the femoral head was measured by 2D quantitative analysis with using mid-coronal and mid-sagittal MRIs, and by 3D quantitative analysis with using serial continuous coronal MRIs and 3D reconstruction software. The necrotic fraction of the specimen was physically measured by the fluid displacement method. The necrotic fraction according to MRI 2D or 3D quantitative analysis was compared with that of the specimen by using Spearman's correlation test. On the correlative analysis, the necrotic fraction by MRI 2D quantitative analysis and quantitative analysis of the specimen showed moderate correlation (r = 0.657); on the other hand, the necrotic fraction by MRI 3D quantitative analysis and quantitative analysis of the specimen demonstrated a strong correlation (r = 0.952) (ρ < 0.05). MRI 3D quantitative analysis was more accurate than 2D quantitative analysis using MRI for measuring osteonecrosis of the femoral head. Therefore, it may be useful for predicting the clinical outcome and deciding the proper treatment option

  10. INFLUENCE OF SILANE HEAT TREATMENT ON THE TENSILE BOND STRENGTH BETWEEN EX-3 SYNTHETIC VENEERING PORCELAIN AND COMPOSITE RESIN USING FIVE DIFFERENT ACTIVATION TEMPERATURES

    Directory of Open Access Journals (Sweden)

    Spartak Yanakiev

    2017-02-01

    Full Text Available Purpose: The purpose of the present study is to assess the effect of five different silane activation temperatures and eight activation methods on the tensile bond strength between one veneering porcelain and one composite resin material. Material and methods: A total of 81 ceramic rods were made of EX-3 veneering ceramic (Kuraray Noritake Dental, Japan. Sintered ceramic bars were grinded with diamond disks to size 10x2x2mm ± 0,05mm. The front part of each bar was polished. After ultrasonic cleaning in distilled water, the specimens were divided into nine groups. Silane was activated with air at room temperature, 38º С, 50º С, 100º С, 120º С using a custom made blow drier. In a silicone mold, a composite resin Z250 (3М ESPE, St. Paul, USA was condensed toward the bond ceramic surface. A total of 81 specimens approximately 2,0 cm long were prepared for tensile bond testing. One way ANOVA, followed by Bonferroni and Games-Howell tests were used for statistical analysis. Results: The lowest tensile bond strength was observed in the control group (3,51MPa. Group 2 yielded the highest bond strength among all groups (19,54MPa. Silane heat treatment enhanced the bond strength for all treatment methods. Within the polished specimens, the highest bond strength was yielded with warm air at 120ºС (11,31MPa. Conclusion: The most effective method for bonding Z250 composite resin to EX-3 veneering ceramic includes HF etching, silane, and adhesive resin. The most effective heat treatment method for bonding is hot air at 120ºС.

  11. Influence of heat treatments for laser welded semi solid metal cast A356 alloy on the fracture mode of tensile specimens

    CSIR Research Space (South Africa)

    Kunene, G

    2008-09-01

    Full Text Available were then butt laser welded. It was found that the pre-weld as cast, T4 and post-weld T4 heat treated specimens fractured in the base metal. However, the pre-weld T6 heat treated specimens were found to have fractured in the heat affected zone (HAZ)...

  12. Tensile properties of candidate structural materials for high power spallation sources at high helium contents

    Science.gov (United States)

    Jung, P.; Henry, J.; Chen, J.

    2005-08-01

    Low activation 9%Cr martensitic steels EUROFER97, pure tantalum, and low carbon austenitic stainless steel 316L were homogeneously implanted with helium to concentrations up to 5000 appm at temperatures from 70 °C to 400 °C. The specimens were tensile tested at room temperature and at the respective implantation temperatures. In all materials the helium caused an increased in strength and reduction in ductility, with both changes being generally larger at lower implantation and testing temperatures. After implantation some work hardening was retained in 316L and in tantalum, while it almost completely disappeared in EUROFER97. After tensile testing, fracture surfaces were analysed by scanning electron microscopy (SEM). Implantation caused reduction of necking, but up to concentrations of 2500 appm He fracture surface still showed transgranular ductile appearance. Completely brittle intergranular fracture was observed in tantalum at 9000 appm He and is also expected for EUROFER97 at this concentration, according to previous results on similar 9%Cr steels.

  13. Evaluation of the histological and mechanical features of tendon healing in a rabbit model with the use of second-harmonic-generation imaging and tensile testing.

    Science.gov (United States)

    Hase, E; Sato, K; Yonekura, D; Minamikawa, T; Takahashi, M; Yasui, T

    2016-11-01

    This study aimed to evaluate the histological and mechanical features of tendon healing in a rabbit model with second-harmonic-generation (SHG) imaging and tensile testing. A total of eight male Japanese white rabbits were used for this study. The flexor digitorum tendons in their right leg were sharply transected, and then were repaired by intratendinous stitching. At four weeks post-operatively, the rabbits were killed and the flexor digitorum tendons in both right and left legs were excised and used as specimens for tendon healing (n = 8) and control (n = 8), respectively. Each specimen was examined by SHG imaging, followed by tensile testing, and the results of the two testing modalities were assessed for correlation. While the SHG light intensity of the healing tendon samples was significantly lower than that of the uninjured tendon samples, 2D Fourier transform SHG images showed a clear difference in collagen fibre structure between the uninjured and the healing samples, and among the healing samples. The mean intensity of the SHG image showed a moderate correlation (R 2 = 0.37) with Young's modulus obtained from the tensile testing. Our results indicate that SHG microscopy may be a potential indicator of tendon healing.Cite this article: E. Hase, K. Sato, D. Yonekura, T. Minamikawa, M. Takahashi, T. Yasui. Evaluation of the histological and mechanical features of tendon healing in a rabbit model with the use of second-harmonic-generation imaging and tensile testing. Bone Joint Res 2016;5:577-585. DOI: 10.1302/2046-3758.511.BJR-2016-0162.R1. © 2016 Yasui et al.

  14. Tensile properties of in situ synthesized titanium matrix composites reinforced by TiB and Nd2O3 at elevated temperature

    International Nuclear Information System (INIS)

    Geng Ke; Lu Weijie; Zhang Di; Sakata, Taokao; Mori, Hirotaro

    2003-01-01

    Titanium matrix composites reinforced with TiB and Nd 2 O 3 were prepared by a non-consumable arc-melting technology. X-ray diffraction (XRD) was used to identify the phases in the composites. Microstructures of the composites were observed by means of optical microscope (OM). There are three phases: TiB, Nd 2 O 3 and titanium matrix. TiB grows in needle shape, whereas Nd 2 O 3 grows in lath shape. Tensile properties of the composites were tested at 773, 823 and 873 K. Both the fracture surfaces and longitudinal sections of the fractured tensile specimens were comprehensively examined by scanning electron microscope (SEM). The fracture mode and fracture process at different temperatures were analyzed and explained. It shows that the tensile strength of the composites has a significant improvement at elevated temperatures compared to titanium matrix. The ductility of the composites improves with the content of neodymium and the test temperatures. The titanium composite exhibits different fracture modes at different test temperatures

  15. Effect of Numbers of Load Cycling on the Micro Tensile Bond Strength of Total Etch Adhesives to Dentin

    Directory of Open Access Journals (Sweden)

    AR Daneshkazemi

    2013-06-01

    Full Text Available Introduction: Today load cycling is used for similarity of invitro and invivo studies, though different results were reported in different studies. Therefore, this study aimed to investigate the effect of load cycling on micro tensile bond strength of two total etch adhesives to dentin. Methods: Enamel of 48 molar teeth were removed to expose the superficial dentin. The teeth were randomly divided into two equal groups, and were restored with Single bond (SB, ExciTE and Synergy composite. Then the teeth of each group were divided to 4 equal sub groups. Moreover, load cycling of 0, 50, 100, 200 k load cycle with 50 newton load was used. In each sub group, 12 hour glass slabs with 1mm2 thickness were made. Then the samples were loaded by Dartec testing machine (Model HC/10 with 1 mm/min cross head speed to make the fracture occur. Data were analyzed by ANOVA, t-test, Bonferroni tests. Results: The most micro tensile bond strength belonged to ExciTE without load cycling and lowest refered to SB with 200 k. There was a significant difference between the groups (p ExciTE= 0.0001, p SB = 0.001. Micro tensile bond strength in SB group was significantly lower than ExciTE (p= 0.001. Moreover, load cycling had negative effect on micro tensile bond strength. Conclusion: By increasing load cycling, micro tensile bond strength of both bondings decreased significantly

  16. Effect of strain rate on the tensile properties of α- and delta-stabilized plutonium

    International Nuclear Information System (INIS)

    Hecker, S.S.; Morgan, J.R.

    1975-01-01

    The tensile properties of unalloyed α-Pu and 3.4 at. percent Ga-stabilized delta-Pu were determined at strain rates from 10 -5 to 100/s. Tests at strain rates less than 10 -2 /s were conducted on an Instron Testing Machine; those at strain rates between 10 -2 and 3/s on a closed-loop electrohydraulic MTS system; and those at strain rates greater than 3/s on a specially modified Charpy Impact Tester. Three lots of delta-Pu, one rolled and annealed and the other two cast and homogenized, were tested. The 0.2 percent yield strengths and ultimate tensile strengths increased by an average of 5.2 and 6.0 MPa per factor of 10 increase in strain rate. This increase was achieved without penalty in tensile ductility as measured by total elongation to fracture and by reduction in area. The isostatically pressed α-Pu specimens also showed a large increase in fracture stress with strain rate (34.3 MPa per factor to 10 increase in strain rate). The fracture was macroscopically brittle (plastic strains less than 0.3 percent) although we observed extensive evidence of microscopic flow in the ductile dimple-type appearance of the fracture surfaces. The strain to fracture appeared to exhibit a minimum at a strain rate of 10 -2 /s. (U.S.)

  17. Imaging button battery ingestions and insertions in children: a 15-year single-center review

    Energy Technology Data Exchange (ETDEWEB)

    Pugmire, Brian S.; Trout, Andrew T. [Cincinnati Children' s Hospital Medical Center, Department of Radiology, Cincinnati, OH (United States); Lin, Tom K.; Pentiuk, Scott [Cincinnati Children' s Hospital Medical Center, Division of Gastroenterology Hepatology and Nutrition, Cincinnati, OH (United States); De Alarcon, Alessandro; Hart, Catherine K. [Cincinnati Children' s Hospital Medical Center, Department of Pediatric Otolaryngology, Cincinnati, OH (United States); University of Cincinnati College of Medicine, Department of Otolaryngology-Head and Neck Surgery, Cincinnati, OH (United States)

    2017-02-15

    Recent studies have shown an increase in morbidity associated with button battery ingestions in children. To perform a comprehensive, imaging-focused review of all patients with confirmed button battery ingestions/insertions imaged at our institution in the last 15 years. Radiology reports from Jan. 1, 2000, to July 12, 2015, were searched for the terms ''battery'' and ''batteries.'' Confirmed cases of battery ingestion/insertion for which images were available were reviewed. Cases were reviewed for imaging studies performed, imaging findings, patient demographics, clinical history and management. Two pediatric gastroenterologists reviewed endoscopic images and graded mucosal injuries in selected cases. Two hundred seventy-six cases were reviewed. All patients were imaged with radiography, 19 with fluoroscopy (6.8%), and 4 with CT (1.4%). Batteries retained in the esophagus (n = 27, 9.8%) were larger in diameter on average than those that had passed distally (22.1 ± 3.3 mm vs. 13.7 ± 1.6 mm, P<0.0001). Battery diameter ≥20 mm was associated with esophageal impaction (P<0.0001) and higher grade esophageal injury (P<0.0001). Mean battery diameter was greater for patients with grade 1 or higher mucosal injury than for patients with no mucosal injury (22.1 ± 2.1 mm vs. 14.7 ± 4.5 mm, P<0.0001). Sixteen percent (4/25) of patients with grade ≥1 esophageal injury had batteries in the stomach on initial imaging. Five patients (1.8%) had serious clinical complications (e.g., esophageal perforation, tracheoesophageal fistula). Button batteries >20mm in diameter warrant increased clinical scrutiny due to higher likelihood and severity of injury. Implementation of recent pediatric gastroenterology societal guidelines will likely lead to a substantial increase in the number of CT and MRI examinations. (orig.)

  18. Tensile properties of carbon black-filled natural rubber latex films using two different approaches of film preparation

    Science.gov (United States)

    Jarkasi, Siti Aisyah; Samsuri, Azemi; Hashim, M. Y. Amir; Kamarun, Dzaraini

    2017-09-01

    A study was structured to investigate the effects of two different approaches of black-filled NRL films preparation on tensile strengths and tensile stress at 100% strain (M100). In the "First Approach", carbon black dispersion was added into the NRL and mixed using mechanical stirrer. Then the black-filled NRL was coagulated with acetic acid and dried to form NR black-filled masterbatch. This black-filled NR masterbatch was then masticated and mixed with other compounding ingredients on the 2-roll mill. In the "Second Approach", carbon black dispersion was mixed with NRL plus all other compounding ingredients using a mechanical stirrer at high mechanical stirring speed (200 rpm) for 3 hrs. Tensile test-pieces from these two rubber specimens were tested according to ISO37. It was observed that the tensile strengths are affected by both methods. In the case of masticated latex masterbatch, the black-filled NRL films gave higher tensile strength (25-27 MPa) as compared to un-masticated black-filled NRL films (11-17 MPa). The optimum amount of filler loading for highest tensile strength in both approaches was 20 phr of carbon black. However these different approaches did not give significant effect to the elongation at break, EB and M100. SEM images of samples prepared from both approaches suggested that the dispersion of filler in the rubber matrix was better in the masticated samples compared to the un-masticated samples. The reason for the difference in the tensile strength between the two black-filled rubbers might be associated with the degree of dispersions and the uniformity of the dispersions within the rubber matrix. The first mixing approach involved high mechanical shearing action during mastication and mixing process on the 2-roll mill. The high shearing actions were able to breakdown filler aggregates efficiently and distributed the dispersed filler uniformly within the rubber matrix. In the second approach, the breakdown of filler aggregates relied on

  19. Mechanical splicing of superelastic Cu–Al–Mn alloy bars with headed ends

    Science.gov (United States)

    Kise, S.; Mohebbi, A.; Saiidi, M. S.; Omori, T.; Kainuma, R.; Shrestha, K. C.; Araki, Y.

    2018-06-01

    This paper examines the feasibility of mechanical splicing using a steel coupler to connect headed ends of superelastic Cu–Al–Mn alloy (Camalloy) bars and steel reinforcing bars to be used in concrete structures. Although threading of Camalloy is as easy as that of steel, mechanical splicing using threaded ends requires machining of Camalloy bars into dog-bone shape to avoid brittle fracture at the threaded ends. The machining process requires significant time and cost and wastes substantial amount of the material. This paper attempts to resolve this issue by applying mechanical splicing using steel couplers to connect headed ends of Camalloy and steel reinforcing bars. To study its feasibility, we prepare 3 specimens wherein both ends of each Camalloy bar (13 mm diameter and 300 mm length) are connected to steel reinforcing bars. The specimens are tested under monotonic, single-cycle, and full-cycle tension loading conditions. From these tests, we observed (1) excellent superelasticity with recoverable strain of around 6% and (2) large ductility with fracture strain of over 19%. It should be emphasized here that, in all the specimens, ductile fracture occurred at the locations apart from the headed ends. This is in sharp contrast with brittle fracture of headed superelastic Ni–Ti SMA bars, most of which took place around the headed ends. From the results of the microstructural analysis, we identified the following reasons for avoiding brittle fracture at the headed ends: (1) Precipitation hardening increases the strength around the boundary between the straight and headed (tapered) portions, where stress concentration takes place. (2) The strength of the straight portion does not increase significantly up to the ductile fracture if its grain orientation is close to 〈0 0 1〉.

  20. Influence of deuterium content on tensile behavior of Zr-2.5Nb pressure tube material in the temperature range of ambient to 300 degC

    International Nuclear Information System (INIS)

    Bind, A.K.; Singh, R.N.; Chakravartty, J.K.; Dhandharia, Priyesh; Ghosh, Agnish; More, Nitin S.; Chhatre, A.G.; Vijayakumar, S.

    2011-08-01

    Tensile properties of autoclaved zirconium-2.5 wt. % niobium pressure tube material were evaluated by uniaxial tension tests at temperatures between 25 and 300 degC and under strain-rates of 1.075 x 10 -4 /s. Six number of Zr-2.5Nb alloy pressure tube spools of length 130 mm were obtained from pressure tube number 19-2557-2. Five spools were polished with abrasive paper to remove the oxide layer. These spools were gaseously charged with controlled amount of deuterium. The target deuterium concentrations were 25, 50, 75, 100 and 200 wppm of hydrogen equivalent. Ten samples were machined by EDM wire cutting from every spool. The tensile specimen axis was oriented along longitudinal direction of the tube. Metallographic examination of the deuterium charged samples suggested that the deuterides were predominantly circumferential deuterides. Analysis of tensile results showed that both yield and ultimate tensile strengths of this alloy decreased monotonically with increasing test temperatures. The tensile ductility decreased marginally with increase in test temperature from ambient to 300 degC. It was also observed that both strength and ductility appear to be unaffected by deuterium content at all temperatures, thereby suggesting that at least up to 200 wppm (Heq.) of deuterium tensile properties are not influenced by deuterium. (author)