WorldWideScience

Sample records for brachytherapy ajuste dos

  1. Aplicación de dos pruebas estadísticas de bondad de ajuste en muestras complejas: un caso práctico en el campo forestal

    OpenAIRE

    Quintero-Méndez, María A.; Durán-Núñez, Mariano J.

    2008-01-01

    En esta investigación se comparan dos pruebas de bondad de ajuste en términos de su error tipo I: ji-cuadrada de Pearson y Rao-Scott con corrección de segundo orden, aplicadas a datos recolectados mediante técnicas de muestreo que no cumplen los supuestos de independencia e igual probabilidad de inclusión de las observaciones, llamadas muestras complejas. Ambas pruebas se usaron para ajustar categorías diamétricas en una plantación de gmelina (Gmelina arborea), aplicando muestreo sistemático ...

  2. Brachytherapy

    Science.gov (United States)

    ... the use of a type of energy, called ionizing radiation, to kill cancer cells and shrink tumors. External ... In all cases of brachytherapy, the source of radiation is encapsulated ... non-radioactive metallic capsule. This prevents the radioactive materials ...

  3. Política socioambiental e de entorno do BNDES: dos ajustes espaciais aos corretivos territoriais: os casos das UHEs de Santo Antônio e Jirau (RO e da UHE de Belo Monte (PA

    Directory of Open Access Journals (Sweden)

    Luis Fernando Novoa Garzon

    2015-07-01

    Full Text Available O artigo procura apresentar a posição e o discurso paradoxais de um Banco que é ao mesmo tempo viabilizador de macro-ajustes espaciais e propositor de micro-correções territoriais. A política socioambiental e de entorno do BNDES são avaliadas a partir dos casos dos grandes projetos, especificamente o Complexos Hidrelétricos do Madeira e de Belo Monte.

  4. Influência do tamanho e da rigidez dos objetos nos ajustes proximais e distais do alcance de lactentes Influence of object size and rigidity on proximal and distal adjustments to infant reaching

    Directory of Open Access Journals (Sweden)

    NACF Rocha

    2006-09-01

    Full Text Available CONTEXTUALIZAÇÃO: Estudos têm identificado que as propriedades dos objetos induzem os ajustes no alcance; no entanto, poucos investigaram a influência específica do tamanho e rigidez dos objetos em lactentes jovens. OBJETIVO: Verificar se lactentes de 4 a 6 meses realizam ajustes proximais e distais ao alcançarem objetos de diferentes tamanhos e rigidez. MÉTODOS: Nove lactentes saudáveis foram posicionados em uma cadeira inclinada a 50º. Quatro objetos foram apresentados, um rígido grande (RG, um rígido pequeno (RP, um maleável grande (MG e um maleável pequeno (MP, por um período de 1 minuto cada. Em um total de 384 alcances, foram analisados os ajustes proximais (alcance uni e bimanual e distais (orientação da mão horizontal, vertical e oblíqua; mão aberta, fechada e semi-aberta e o sucesso do alcance dos objetos. RESULTADOS: Constatou-se ajuste bimanual para o objeto RG e unimanual para os demais. A orientação da mão oblíqua foi predominante no toque dos objetos, enquanto para a preensão dos mesmos, a predominância foi a vertical, principalmente para o objeto RG. A orientação horizontal não foi observada na preensão do objeto RG. A mão semi-aberta foi mais freqüente no início do alcance para todos os objetos, enquanto no toque do objeto RG a mão aberta foi predominante. O sucesso do alcance foi maior para os objetos maleáveis (MG, MP do que para os rígidos (RG e RP. CONCLUSÃO: Lactentes jovens estudados são capazes de planejar e ajustar seus movimentos baseados na percepção das propriedades físicas dos objetos, o que sugere interação percepção-ação.BACKGROUND: Studies have identified that object properties lead to adjustments to reaching. However, few have investigated the specific influence of object size and rigidity among young infants. OBJECTIVE: To verify whether four to six-month-old infants make proximal and distal adjustments when reaching for objects of different sizes and rigidity. METHOD

  5. DOS.

    Science.gov (United States)

    Traven, Bill

    1988-01-01

    Discusses using the DOS PATH command (for MS-DOS) to enable the microcomputer user to move from directory to directory on a hard drive. Lists the commands to be programed, gives examples, and explains the use of each. (MVL)

  6. Tratamento conservador ocular dos melanomas de coróide com braquiterapia utilizando placas de iodo-125 Conservative treatment of choroidal melanomas using iodine brachytherapy

    Directory of Open Access Journals (Sweden)

    Antônio Cássio Assis Pellizzon

    2004-08-01

    Full Text Available OBJETIVO: Avaliar, retrospectivamente, o resultado do tratamento conservador do melanoma de coróide, por meio de braquiterapia, usando placas episclerais de iodo-125 (modelo 6711, Amershan. MATERIAIS E MÉTODOS: Foram avaliados 49 pacientes portadores de melanoma de coróide tratados no Hospital do Câncer, São Paulo, SP, de março de 2001 a janeiro de 2003. Os seguintes parâmetros foram analisados e correlacionados ao controle local e sobrevida: sexo, idade, dimensões da lesão, tempo de tratamento e doses no ápice e base das lesões. RESULTADOS: Com diâmetro máximo da base do tumor de 17 mm e altura máxima de 12 mm, observamos que as doses na base do tumor variaram de 213 a 463 Gy (mediana de 347 Gy e no ápice, de 51 a 250 Gy (mediana de 91 Gy. As taxas de preservação ocular, sobrevida livre de doença e conservação ocular, atuariais em dois anos, foram de 96%, 93,5% e 96,3%, respectivamente. Através de análise univariada, o único fator prognóstico para controle local nesta análise foi a altura do tumor menor que 6 mm (p = 0,0348. CONCLUSÃO: A braquiterapia levou a uma taxa bastante satisfatória de controle local, confirmando que a altura do tumor é um dos fatores prognósticos importantes desse parâmetro.OBJECTIVE: To retrospectively evaluate the results of conservative therapy using episcleral iodine-125 (model 6711, Amershan plaque for brachytherapy of choroidal melanoma. MATERIALS AND METHODS: We evaluated 49 patients with choroidal melanoma treated at "Hospital do Câncer", São Paulo, Brazil, from March 2001 to January 2003. The following clinical parameters were analyzed and correlated with local control and survival rate: gender, age, lesion dimension, treatment duration, as well as doses in apex and base of the tumors. RESULTS: The maximum diameter and height of the base of the tumors treated were 17 mm and 12 mm, respectively. Doses at those points ranged from 213 to 463 Gy (median: 347 Gy and 51 to 250 Gy

  7. Estilos relacionales parentales y ajuste adolescente

    OpenAIRE

    Oliva Delgado, Alfredo; Parra Jiménez, Agueda; Arranz Freijo, Enrique

    2008-01-01

    En este artículo se presentan los resultados de un estudio realizado sobre una muestra de 848 adolescentes de edades comprendidas entre los 12 y los 17 años, que cumplimentaron un cuestionario que incluía una escala con 6 dimensiones sobre su percepción del estilo parental o relacional materno y paterno y otros instrumentos para evaluar el ajuste adolescente. La realización de un análisis de conglomerados a partir de las puntuaciones en las 6 dimensiones que componían la escala re...

  8. Impacto del ajuste por inflación financiero en la gestión empresarial

    Directory of Open Access Journals (Sweden)

    Oda Hilda Gómez de Angulo

    2009-01-01

    Full Text Available La inflación es un fenómeno económico que afecta la situación financiera de las organizaciones, por lo que existe la Declaración de Principios de Contabilidad No. 10 (DPC-10 que establece las normas para efectuar el ajuste por inflación a los estados financieros. Con el propósito de conocer el impacto de este ajuste, se seleccionaron dos empresas que realizan actividades diferentes. Se efectuó una revisión bibliográfica y documental de la DPC-10 y, con base a los informes al cierre de cada ejercicio económico de las empresas objeto de estudio, se recopilaron y prepararon los datos en una misma unidad de medida para efectos de comparación, análisis e interpretación. Los resultados obtenidos indican que en la empresa regida por la Comisión Nacional de Valores se justifica el ajuste por inflación financiero debido a la naturaleza de la estructura financiera y a que la toma de decisiones administrativas y legales se realiza con base a esta información; mientras que en la institución regida por la Superintendencia de Cajas de Ahorro no se justifica la presentación del ajuste por inflación financiero, ya que no aporta ningún valor agregado a la organización y la toma de decisiones se realiza con base a los estados financieros históricos.

  9. Prueba para el error de ajuste de un modelo multivariante

    OpenAIRE

    Rodríguez, Luis H.

    2012-01-01

    En el ajuste de un modelo a una serie de observaciones se presenta el interesante problema de decidir sobre lo adecuado del modelo para describir tales observaciones .. Una prueba para esta clase de decisión se denomina "Error de ajuste", No conocíamos una tal prueba para el caso de un modelo multivariante  (cada observación es un vector), por lo que este articulo hacemos una extensión de la  técnica de  "error de ajuste" utilizada en el análisis  univariante al caso multivariante,  y se prod...

  10. El ajuste temporal: criterio de ejecución distintivo de la inteligencia deportiva

    OpenAIRE

    Roca i Balasch, Josep

    1998-01-01

    En este artículo se propone una consideración de la actividad física y el deporte como una actividad inteligente en base a una concepción amplia de inteligencia y en base a la atención al parámetro tiempo como criterio de ajuste psicológico. Por lo que respecta a la primera afirmación, se afirma que tanto las habilidades perceptivo-motrices como las habilidades interactivas constituyen dos dimensiones de adaptación humana tradicionalmente infravaloradas en aras de las habilidades cognoscitiva...

  11. Prostate cancer brachytherapy

    International Nuclear Information System (INIS)

    Abreu, Carlos Eduardo Vita; Silva, Joao L. F.; Srougi, Miguel; Nesrallah, Adriano

    1999-01-01

    The transperineal brachytherapy with 125 I/Pd 103 seed implantation guided by transurethral ultrasound must be presented as therapeutical option of low urinary morbidity in patients with localized prostate cancer. The combined clinical staging - including Gleason and initial PSA - must be encouraged, for definition of a group of low risk and indication of exclusive brachytherapy. Random prospective studies are necessary in order to define the best role of brachytherapy, surgery and external beam radiation therapy

  12. Prostate brachytherapy - discharge

    Science.gov (United States)

    Implant therapy - prostate cancer - discharge; Radioactive seed placement - discharge ... You had a procedure called brachytherapy to treat prostate cancer. Your treatment lasted 30 minutes or more, ...

  13. Document de travail no.8: Ajustement structurel et consolidation de ...

    International Development Research Centre (IDRC) Digital Library (Canada)

    13 déc. 2010 ... Marie-France Guimond ... Très peu de recherches ont été faites sur le rôle des plans d'ajustement structurel dans le contexte des pays ... Gender and climate change-induced conflict in pastoral communities: Turkana, Kenya.

  14. Ajustement structurel et consolidation de la paix Une source de ...

    International Development Research Centre (IDRC) Digital Library (Canada)

    mguimond

    Tableau 4 : Corrélation : Indicateurs-pays pour la politique étrangère et ajustement .... incorporés aux réformes macroéconomiques du cadre stratégique de lutte ...... Le plafond sur le recrutement de fonctionnaires a été considéré comme une ...

  15. LA POLÍTICA SOCIAL EN TIEMPOS DE AJUSTE

    Directory of Open Access Journals (Sweden)

    Leonardo Garnier Rímolo

    2011-09-01

    Full Text Available La política social está nuevamente de moda. Hace unos años, eran la estabilización y el ajuste los temas que dominaban la literatura, los debates y hasta las conversaciones de los economistas. Hoy, es cada vez más frecuente la referencia a la pobreza, el costo social del ajuste, el rostro humano de la política económica, el gasto social, la salud, la educación, en fin, todos aquellos temas relativos a la calidad de vida y el desarrollo humano. A diferencia del pasado, sin embargo, este redescubrimiento de los objetivos sociales del desarrollo no olvida, sino que parte precisamente del reconocimiento de las limitaciones materiales y financieras que enfrentan las sociedades menos desarrolladas. La discusión actual busca redefinir el sentido de la política social en los tiempos del ajuste o, si se quiere, redefinir los procesos de ajuste a la luz de su verdadero objetivo: el desarrollo social.

  16. Advancements in brachytherapy

    DEFF Research Database (Denmark)

    Tanderup, Kari; Ménard, Cynthia; Polgar, Csaba

    2017-01-01

    Brachytherapy is a radiotherapy modality associated with a highly focal dose distribution. Brachytherapy treats the cancer tissue from the inside, and the radiation does not travel through healthy tissue to reach the target as with external beam radiotherapy techniques. The nature of brachytherap...

  17. Efectos de entrenar para cumplir criterios de congruencia en tareas de ajuste lector

    Directory of Open Access Journals (Sweden)

    Germán Morales-Chávez

    2010-01-01

    Full Text Available La presente investigación evaluó los efectos de entrenar estudiantes universitarios para satisfacer criterios de congruencia en tareas de ajuste lector con base en parámetros de congruencia y de coherencia. El grupo experimental fue entrenado para satisfacer criterios de congruencia y fue expuesto a dos pruebas de evaluación en satisfacción de criterios de congruencia y coherencia. El grupo control solo fue sometido a las pruebas de evaluación. Los resultados revelan que el entrenamiento favoreció la satisfacción de criterios tanto de congruencia como de coherencia. Se discute la relevancia del desempeño efectivo en una situación lectora con criterios de congruencia como condición para el desarrollo de conductas lectoras funcionalmente más complejas.

  18. EFECTOS DE ENTRENAR PARA CUMPLIR CRITERIOS DE CONGRUENCIA EN TAREAS DE AJUSTE LECTOR

    Directory of Open Access Journals (Sweden)

    Germán Morales-Chávez

    2010-01-01

    Full Text Available La presente investigación evaluó los efectos de entrenar estudiantes universitarios para satisfacer criterios de congruenciaen tareas de ajuste lector con base en parámetros de congruenciay de coherencia. El grupo experimental fue entrenadopara satisfacer criterios de congruencia y fue expuestoa dos pruebas de evaluación en satisfacción de criterios decongruencia y coherencia. El grupo control solo fue sometidoa las pruebas de evaluación. Los resultados revelan que elentrenamiento favoreció la satisfacción de criterios tanto decongruencia como de coherencia. Se discute la relevancia deldesempeño efectivo en una situación lectora con criterios decongruencia como condición para el desarrollo de conductaslectoras funcionalmente más complejas.

  19. ESTRATEGIAS DE AJUSTE ANTE CHOQUES HIPOTÉTICOS DE OFERTA Y DEMANDA. Resultados de una encuesta a empresas mexicanas

    Directory of Open Access Journals (Sweden)

    Paula Sánchez-Romeu

    2015-01-01

    Full Text Available En este artículo se analizan estrategias de ajuste para hacer frente a choques hipotéticos de oferta y demanda utilizadas por 1 138 empresas mexicanas encuestadas por el Banco de México en 2012. Los resultados del análisis muestran que la respuesta de las empresas ante los dos tipos de choque en general no es simétrica y que éstas reaccionan combinando estrategias (principalmente eligen reducir costos, con lo cual moderan los ajustes a precios y producción. Más competencia hace que las empresas utilicen con más intensidad las estrategias de ajuste y favorece la flexibilidad de los precios. Ante cualquier choque, los costos que más se reducen son los no laborales y los que genera el empleo temporal. Una alta competencia y un mayor porcentaje de costos laborales intensifican el traspaso de los choques al empleo; por el contrario, los acuerdos colectivos de trabajo mitigan dicho traspaso. No se observa un traspaso de los choques a las percepciones salariales, lo cual, aunado a la baja incidencia de la reducción del salario base, evidencia rigidez en los salarios nominales de las empresas entrevistadas.

  20. Radiation protection in brachytherapy

    International Nuclear Information System (INIS)

    Benitez, Manuel

    1996-02-01

    It covers technical procedures in medical applications for cancer treatment. Radiation protection principles in brachytherapy. Medical uses in therapy for Sr-90, Cs-137, Co-60, Ra-226, Ir-192, Au-198, Bi-214, Pb-214. (The author)

  1. Radioactive sources in brachytherapy:

    OpenAIRE

    Burger, Janez

    2003-01-01

    Background. In modern brachytherapy, a greast step forward was made in the 1960s in France with the introduction of new radioactive isotopes and new techniques. These innovations spread rapidly across Europe, though no single dosimetry standard had been set by then. In the new millennium, the advances in brachytherapy are further stimulated by the introduction of 3-D imaging techniques and the latest after loading irradiation equipment that use point sources. The international organiyation IC...

  2. Brachytherapy of endometrial cancers

    International Nuclear Information System (INIS)

    Peiffert, D.; Hoffstetter, S.; Charra-Brunaud, C.

    2003-01-01

    Endometrial adenocarcinomas rank third as tumoral sites en France. The tumors are confined to the uterus in 80% of the cases. Brachytherapy has a large place in the therapeutic strategy. The gold standard treatment remains extra-fascial hysterectomy with bilateral annexiectomy and bilateral internal iliac lymph node dissection. However, after surgery alone, the rate of locoregional relapses reaches 4-20%, which is reduced to 0-5% after postoperative brachytherapy of the vaginal cuff. This postoperative brachytherapy is delivered as outpatients treatment, by 3 or 4 fractions, at high dose rate. The utero-vaginal preoperative brachytherapy remains well adapted to the tumors which involve the uterine cervix. Patients presenting a localized tumor but not operable for general reasons (< 10%) can be treated with success by exclusive irradiation, which associates a pelvic irradiation followed by an utero-vaginal brachytherapy. A high local control of about 80-90% is obtained, a little lower than surgery, with a higher risk of late complications. Last but not least, local relapses in the vaginal cuff, or in the perimeatic area, can be treated by interstitial salvage brachytherapy, associated if possible with external beam irradiation. The local control is reached in half of the patients, but metastatic dissemination is frequent. We conclude that brachytherapy has a major role in the treatment of endometrial adenocarcinomas, in combination with surgery, or with external beam irradiation for not operable patients or in case of local relapses. It should use new technologies now available including computerized after-loaders and 3D dose calculation. (authors)

  3. Afterloading techniques in brachytherapy

    International Nuclear Information System (INIS)

    Kirsch, M.; Orban, R.; Lorenz, B.

    1981-01-01

    The advantages of applying modern afterloading methods in brachytherapie of malignant diseases are outlined. They include, among other things, a considerable reduction in radiation exposure to staff involved. Furthermore, the radiation protection requirements imposed by the licensing authority on the construction, equipment and operation of remote controlled afterloading installations with gamma sources of up to 4 TBq (108 Ci) have been compiled. (author)

  4. Brachytherapy for oral cancer

    International Nuclear Information System (INIS)

    Monzen, Yoshio; Ajimu, Akira; Morikawa, Minoru; Hayashi, Nobuyuki; Yoshida, Shintarou; Ashizawa, Kazuto; Hayashi, Kuniaki; Ikenaga, Kouji; Sakamoto, Ichirou.

    1988-01-01

    13 cases with oral cancer were treated using brachytherapy at the Department of Radiology, Nagasaki University Hospital from September 1985 to February 1988. Among 11 cases of tongue cancer, T1 and T2 cases were well controlled by radiation therapy using 226 Ra needles. Cancer of oral floor and buccal mucosa were controlled by the use of 192 Au grains. (author)

  5. [Brachytherapy of brainstem tumors].

    Science.gov (United States)

    Julow, Jenö; Viola, Arpád; Major, Tibor; Valálik, István; Sági, Sarolta; Mangel, László; Kovács, Rita Beáta; Repa, Imre; Bajzik, Gábor; Németh, György

    2004-01-20

    The optimal therapy of brain stem tumours of different histopathology determines the expected length of survival. Authors report 125Iodine interstitial irradiation of brain stem tumours with stereotactic brachytherapy. Two patients having brain stem tumours were suffering from glioma or from metastases of a carcinoma. In Case 1 the tumour volume was 1.98 cm3 at the time of planning interstitial irradiation. The control MRI examination performed at 42 months post-op showed a postirradiation cyst size of 5.73 cm3 indicating 65.5% shrinkage. In Case 2 the shrinkage was more apparent as the tumour volume measured on the control MRI at 8 months post-op was only 0.16 cm3 indicating 97.4% shrinkage of the 6.05 cm3 target volume at the time of brachytherapy with the metastasis practically disappearing. Quick access to histopathological results of the stereotactic intraoperative biopsy made it possible to carry out the 125Iodine stereotactic brachytherapy immediately after the biopsy, resulting in less inconvenience for patients of a second possible intervention. The control MRI scans show significant shrinkage of tumours in both patients. The procedure can be performed as a biopsy. The CT and image fusion guided 125Iodine stereotactic brachytherapy can be well planned dosimetrically and is surgically precise.

  6. Consumo de sustancias durante la adolescencia:trayectorias evolutivas y consecuencias para el ajuste psicológico

    Directory of Open Access Journals (Sweden)

    Alfredo Oliva

    2008-01-01

    Full Text Available Este estudio ha perseguido dos objetivos fundamentales: encontrar diferentes trayectorias en el consumo de sustancias a lo largo de la adolescencia y analizar las consecuencias que este consumo en la adolescencia temprana y media tiene para el ajuste emocional y comportamental al final de la adolescencia. El estudio, con un diseño descriptivo longitudinal mediante cuestionarios, se llevó a cabo sobre una muestra de 101 adolescentes (63 varones y 38 mujeres que fueron estudiados en 3 ocasiones: a los 13, 15 y 18 años de edad. Los resultados mostraron tres grupos de adolescentes en función de las trayectorias seguidas por su consumo de sustancias: consumo bajo, consumo ascendente y experimentación precoz. La comparación entre estos tres grupos indicó un mejor ajuste psicológico en la adolescencia tardía entre los varones y mujeres del grupo de experimentadores, mientras que los problemas de conducta fueron más frecuentes entre los incluidos en el grupo de consumo ascendente. Por otra parte, los análisis de regresión señalaron que el consumo moderado de sustancias en la adolescencia temprana estaba relacionado con una autoestima más alta y con menos problemas emocionales al final de la adolescencia, pero no con más problemas externos.

  7. Os benefícios da hipoterapia nos ajustes posturais em crianças portadoras de paralisia cerebral

    Directory of Open Access Journals (Sweden)

    Daniela Carrogi Vianna

    2017-05-01

    Full Text Available Paralisia Cerebral é uma afecção encefálica que ocorre na fase maturacional, apresentando seqüelas variáveis, envolvendo desordens de postura e movimentos. Examinaram-se alterações posturais de pacientes portadores de Paralisia Cerebral durante e após a realização de Hipoterapia, observando ajustes posturais. Participaram oito crianças, entre 6 e 12 anos, com tetraparesia espástica, apresentando déficics das reações básicas de endireitamento, proteção e equilíbrio. Utilizou-se a Hipoterapia como terapêutica complementar, exigindo respostas posturais automáticas. As crianças foram submetidas a duas sessões semanais, durante doze meses. Constatou-se melhora das variáveis estudadas, concluindo-se que a Hipoterapia auxilia na ativação dos ajustes posturais em crianças com Paralisia Cerebral.

  8. O ajuste urbano: as políticas do Banco Mundial e do BID para as cidades

    Directory of Open Access Journals (Sweden)

    Pedro Fiori Arantes

    2006-12-01

    Full Text Available Ao ajuste estrutural que se seguiu à crise da dívida no Terceiro Mundo, no início dos anos 80 - e ainda persiste como um ajuste permanente -, parece ter ocorrido um correspondente" ajuste urbano". Em ambos os casos, o Banco Mundial e, na América Latina, o BID, tiveram ação decisiva, em parceria com as elites e tecnocracias locais. As estratégias de ação dessas duas instituições financeiras, apesar de sua forte interferência nas políticas públicas dos países em desenvolvimento, constituem um tema novo e ainda pouco abordado pela pesquisa acadêmica. Em nosso caso, o objetivo foi desvendar o modelo de cidade que tem sido por elas defendido e qual seu significado. Na dissertação que realizei pela FAUUSP, constatei que os empréstimos do Banco Mundial e do BID - que aparecem aos gestores públicos como" tábuas de salvação" em tempos de crise -, não são" neutros" e carregam consigo uma agenda afirmativa: pretendem modelar um determinado padrão de uso do recurso público e de organização do Estado. As duas instituições difundem políticas públicas que seguem critérios empresariais de rentabilidade e um modelo de gestão estatal terceirizada, à mercê de um corpo técnico privado - formado por gerenciadoras de projeto, fundações privadas, ONGs e inúmeros consultores. Seu objetivo é transformar uma parcela dos governos locais nos países em desenvolvimento, especialmente os que administram os territórios que dão suporte aos negócios transnacionais, em estruturas administrativas treinadas para responder aos grandes interesses privados, ao mesmo tempo em que se desembaraçam de qualquer compromisso com a democracia real.

  9. Incertidumbre y ajuste por las cantidades en the General Theory

    Directory of Open Access Journals (Sweden)

    Adolfo Rodríguez Herrera

    2009-06-01

    Full Text Available Robert Clower desarrolla una interpretación de la crítica de Keynes al funcionamiento de la economía capitalista en la cual la incertidumbre explica la incapacidad del sistema para alcanzar un equilibrio en todos los mercados, y en particular en el mercado de trabajo. El incumplimiento del principal supuesto de la economía neoclásica, la información perfecta, hace que la tasa de interés pierda su papel regulador y el sistema la capacidad de ajustarse instantáneamente a través de movimientos de los precios: en presencia de desempleo el ingreso individual deja de ser objeto de optimización por parte de los agentes y cualquier shock externo desencadena un ajuste por las cantidades que Keynes denomina efecto multiplicador y que deja al mercado de empleo sin instrumentos para alcanzar su equilibrio.

  10. Ajuste econômico e desemprego recente no Brasil metropolitano

    Directory of Open Access Journals (Sweden)

    MARCIO POCHMANN

    2015-12-01

    Full Text Available resumo O presente artigo trata da evolução da taxa de desemprego no início do ano 2015. Três partes compõem de forma consecutiva e encadeada a partir da premissa de que as mudanças no interior do mercado de trabalho sinalizadas principalmente pelo aumento dos desempregados são geradas fundamentalmente pelo avanço da recessão na economia brasileira. A primeira parte aponta as principais alterações no rendimento e emprego da mão de obra no mercado de trabalho do Brasil metropolitano durante os meses de janeiro a julho de 2015, enquanto a segunda parte descreve brevemente as características mais importantes que decorrem do aumento recente da taxa de desemprego. Por fim, a terceira parte registra comparativamente os reflexos da adoção das políticas de ajustes econômicos no desemprego em anos selecionados durante as últimas três décadas. Dessa forma, constata-se o grau de intensidade atual na evolução da taxa de desemprego com a de outros momentos vividos no país.

  11. Analysis of the necessary radioprotection procedures in manufacture and transport of iodine-125 sources used in brachytherapy;Analise dos procedimentos de radioprotecao necessarios na manufatura e no transporte de fontes de iodo-125 usadas em braquiterapia

    Energy Technology Data Exchange (ETDEWEB)

    Souza, C.D.; Hilario, K.F.; Rostelato, M.E.C.M. [Instituto de Pesquisas Energeticas e Nucleares (CTR/IPEN/CNEN-SP), Sao Paulo, SP (Brazil). Centro de Tecnologia das Radiacoes

    2009-07-01

    The estimates for the year 2009 show that 466,730 new cancer cases will occur in Brazil. Prostate cancer is the second most incident type. Brachytherapy, a type of radiotherapy, with Iodine-125 sources are an important form of treatment for this kind of cancer. The Energy and Nuclear Research Institute IPEN-CNEN/SP created a project to develop a national prototype of these sources and is implementing a facility for local production. The seeds manufacture in Brazil will allow to diminish the treatment cost and make it possible for a larger number of patients. This study aim to evaluate the procedures for transport and radiation protection requirements for employees with imported sources in order to tailor them for use in the new laboratory. Before being sent to hospitals, the packages are monitored by a radioprotection supervisor. Despite Iodine-125 presents low-energy photons, about 29 keV, local and personal dosimeters are used during transport, as described in the standards. The results showed no significant contamination or occupational exposure, validating the existing method. The transport procedure is correct, according to the regulations. For local production, new detectors should be implemented. (author)

  12. Cronograma de amostragem de alface cultivada em hidroponia para ajuste de curvas de crescimento vegetativo Sampling chronology of hydroponics lettuce plants for adjusting vegetative growth curves

    Directory of Open Access Journals (Sweden)

    Sidinei José Lopes

    2007-10-01

    Full Text Available O objetivo deste trabalho foi determinar o cronograma de amostragem de plantas de alface hidropônica, para ajuste de curvas de crescimento durante o período vegetativo. Foram realizados dois cultivos de alface, variedade Regina, de 8/9/2004 a 19/11/2004 (primavera/verão e 22/2/2005 a 24/5/2005 (verão/outono, em estufas de plástico do Dep. de Fitotecnia, da UFSM, Santa Maria, RS. A partir do ajuste do modelo co-seno com amostragem diária, registrada como padrão, diferentes intervalos entre as amostragens foram simulados para o ajuste do mesmo modelo. A fim de se encontrar o intervalo adequado, foi comparada a variância de falta de ajuste do modelo de amostragem diária com as variâncias de falta de ajuste dos modelos com diferentes intervalos de amostragens pelo teste F. Os cronogramas de amostragens para ajuste de curvas de crescimento de plantas de alface sob hidroponia, para experimentos de primavera/verão e verão/outono, possuem intervalos iguais a dois dias, para fitomassa seca total da planta e da folha; intervalos de quatro dias, para fitomassa de raiz; e, diariamente, para área foliar.The objective of this work was to determinate a sampling chronology to adjust lettuce hidroponic growth curves during its vegetative development. The variety Regina was grown from September 8, 2004 until November 19, 2004 (spring/summer and February 22, 2005 until May 24, 2005 (summer/fall. Plants were placed inside a plastic covered greenhouse in Santa Maria, RS, Brazil. Based on the adjusted cosine model, daily samples were taken as standard and different sampling intervals were simulated in order to better adjust the same model. To estimate de adequate sampling interval a comparison was conducted between the variance of lack of adjustment of the daily sampling with the variance of lack of adjustment of different samplings intervals using an F test. Sampling chronograms for adjusting crop growth curves of hydroponics lettuce plants for both

  13. Glass microspheres for brachytherapy

    International Nuclear Information System (INIS)

    Prado, Miguel O.; Prastalo, Simon; Blaumann, Herman; Longhino, Juan M.; Repetto Llamazares, A.H.V.

    2007-01-01

    We developed the capacity to produce glass microspheres containing in their structure one or more radioactive isotopes useful for brachytherapy. We studied the various facts related with their production: (Rare earth) alumino silicate glass making, glass characterization, microspheres production, nuclear activation through (n,γ) nuclear reactions, mechanical characterization before and after irradiation. Corrosion tests in simulated human plasma and mechanical properties characterization were done before and after irradiation. (author) [es

  14. Computed tomography in brachytherapy

    International Nuclear Information System (INIS)

    Mansfield, C.M.; Lee, K.R.; Dwyer, S.; Zellmer, D.; Cook, P.

    1983-01-01

    CT scanning adds to the ability to evaluate brachytherapy techniques. It provides an additional method in the assessment of patients who are candidates for or who are being treated by brachytherapy. The CT scan can give information regarding the position of the sources and their relation to the tumor and normal structures with greater ease than do orthogonal views. This makes it possible to accurately calculate areas of high or low dose. Potential areas of overdose can be recognized, thereby decreasing the chances of postbrachytherapy complications. CT scanning can be used at various levels of complexity in dosimetry evaluation. Adequate brachytherapy dosimetry information is obtainable from CT slices through one or more levels of the implanted volume. In some instances it is possible to obtain additional information by reconstructing the scans in other planes, e.g., coronal or sagittal. Three-dimensional viewing of the implant is desirable, but it should be pointed out that this approach is time-consuming and beyond the capabilities of most institutions at present. It will be necessary to continue work on three-dimensional treatment planning to make it readily available

  15. Intra coronary brachytherapy

    International Nuclear Information System (INIS)

    Ghofourian, H.; Ghahremani, A.; Oliaie, A.; Taghizadeh Asl, M.

    2002-01-01

    Despite the initial promise of vasculopathy intervention restenosis- a consequence of the (normal) would healing process-has emerged as a major problem. Angiographic restenosis has been reported in 40-60% of patients after successful P TCA. The basic mechanism of restenosis, (acute recoil, negative remodeling and neo intimal hyperplasia), are only partially counteracted by endovascular prosthetic devices (s tents). The rate of in-s tent restenosis, which is primarily caused by neo intimal hyperplasia due to the (micro) trauma of the arterial wall by the s tent struts, has been reduced to 18-32%. Ionizing (beta or gamma) radiations has been established as a potent treatment for malignant disorders. In recent years, there has also been increasing interest among clinicians in the management of benign lesions with radiation. Over the past several years, there has been a growing body of evidence that endovascular brachytherapy has a major impact on the biology of the restenosis. It must be underlined that understanding the biology and pathophysiology of restenosis and assessing various treatment options should preferably be a team effort, with the three g races b eing interventional cardiologist, nuclear oncologist, and industrial partners. The vast amount of data in over 20000 patients from a wide range of randomized controlled trials, has shown that brachytherapy is the only effective treatment for in-s tent restenosis. We are learning more and more about how to improve brachytherapy. While the new coated s tents that we heard about today is fascinating and extremely promising, brachytherapy still has a very important place in difficult patients, such as those with total occlusions, osti al lesions, left main lesions, multivessel disease and diabetes. Regarding to above mentioned tips, we (a research team work, in the Nuclear Research Center Of the Atomic Energy Organization Of Iran), focused on synthesis and preparation of radioactive materials for use in I c-B T. We

  16. Oncentra brachytherapy planning system.

    Science.gov (United States)

    Yang, Jack

    2018-03-27

    In modern cancer management, treatment planning has progressed as a contemporary tool with all the advances in computing power in recent years. One of the advanced planning tools uses 3-dimensional (3D) data sets for accurate dose distributions in patient prescription. Among these planning processes, brachytherapy has been a very important part of a successful cancer management program, offering clinical benefits with specific or combined treatments with external beam therapy. In this chapter, we mainly discussed the Elekta Oncentra planning system, which is the main treatment planning tool for high-dose rate (HDR) modality in our facility and in many other facilities in the United States. HDR is a technically advanced form of brachytherapy; a high-intensity radiation source (3.6 mm in length) is delivered with step motor in submillimeter precision under computer guidance directly into the tumor areas while minimizing injury to surrounding normal healthy tissue. Oncentra planning is the key component to generate a deliverable brachytherapy procedure, which is executed on the microSelectron V3 remote afterloader treatment system. Creating a highly conformal plan can be a time-consuming task. The development of Oncentra software (version 4.5.3) offers a variety of useful tools that facilitate many of the clinical challenging tasks for planning, such as contouring and image reconstruction, as well as rapid planning calculations with dose and dose volume histogram analysis. Oncentra Brachy module creates workflow and optimizes the planning accuracy for wide varieties of clinical HDR treatments, such as skin, gynecologic (GYN), breast, prostate, and many other applications. The treatment file can also be transferred to the afterloader control station for speedy delivery. The design concept, calculation algorithms, and optimization modules presented some key characteristics to plan and treat the patients effectively and accurately. The dose distribution and accuracy of

  17. Development of brachytherapy medium doserate

    International Nuclear Information System (INIS)

    Atang Susila; Ari Satmoko; Ahmad Rifai; Kristiyanti

    2010-01-01

    Brachytherapy has proven to be an effective treatment for different types of cancers and it become a common treatment modality in most radiotherapy clinics. PRPN has had experience in development of Low Dose Rate Brachytherapy for cervix cancer treatment. However the treatment process using LDR device needs 5 hours in time that the patient feel uncomfort. Therefore PRPN develops Medium Dose Rate Brachytherapy with radiation activity not more than 5 Currie. The project is divided into two stages. Purchasing of TPS software and TDS design are held in 2010, and the construction will be in 2011. (author)

  18. Ajuste fiscal nos estados: uma análise do período 1998-2006 Fiscal adjustment in brazilian states

    Directory of Open Access Journals (Sweden)

    Sérgio Wulff Gobetti

    2010-01-01

    Full Text Available O objetivo deste artigo é analisar a forma de enquadramento dos estados ao Programa de Ajuste Fiscal (PAF e à Lei de Responsabilidade Fiscal (LRF, destacando seus impactos nas escolhas de alocação dos recursos públicos e na taxa de investimento. Os resultados obtidos após minucioso trabalho de depuração das bases de dados confirmam a melhoria da situação financeira de estados no período posterior à LRF, mas sugerem que existe um trade-off entre os indicadores fiscais, de um lado, e os investimentos e gastos em infraestrutura, de outro, exigindo uma reflexão sobre a qualidade e sustentabilidade do ajuste fiscal. Os dados orçamentários analisados também apontam evidências de contabilidade criativa.The objective of this article is to offer an analysis of the accommodation by Brazilian states with Fiscal Adjustment Program and with Fiscal Responsibility Act (FRA, showing their impacts on the choices of public resources allocation and on the investment rate. The results obtained after detailed work of data depuration confirm the improvement of financial situation of the states in the period post FRA, but also suggest the existence of a trade-off between fiscal indicators and infrastructure investment, demanding a reflection about the quality and the sustainability of the fiscal adjustment. The budget data analyzed also indicate evidences of creative accountability.

  19. [Developments in brachytherapy].

    Science.gov (United States)

    Ikeda, H

    1995-09-01

    Brachytherapy is one of the ideal methods of radiotherapy because of the concentration of a high dose on the target. Recent developments, including induction of afterloading method, utilization of small-sized high-activity sources such as Iridium-192, and induction of high technology and computerization, have made for shortening of irradiation time and source handling, which has led to easier management of the patient during treatment. Dose distribution at high dose rate (HDR) is at least as good as that of low dose rate (LDR), and selection of fractionation and treatment time assures even greater biological effects on hypoxic tumor cells than LDR. Experience with HDR brachytherapy in uterine cervix cancer using Cobalt-60 during the past 20 years in this country has gradually been evaluated in U.S. and Europe. The indications for HDR treatment have extended to esophagus, bronchus, bile duct, brain, intraoperative placement of source guide, and perineal region using templates, as well as the conventional use for uterus, tongue and so on.

  20. Ajuste oclusal na Ortodontia: por que, quando e como? Occlusal adjustment in Orthodontics: why, when and how?

    Directory of Open Access Journals (Sweden)

    Roberto Carlos Bodart Brandão

    2008-06-01

    Full Text Available INTRODUÇÃO: o conhecimento sobre oclusão dentária deve ser considerado condição fundamental para a prática de uma Ortodontia de qualidade. O diagnóstico feito sem a manipulação do paciente em Relação Cêntrica pode levar à surpresa desagradável de se planejar o tratamento de uma má oclusão e se deparar com outra, depois dos primeiros arcos de nivelamento. Ao usar arcos retangulares, é importante a checagem dos contatos oclusais para se definir o tipo de movimento dentário necessário para o alcance do equilíbrio oclusal e, principalmente, verificar se este movimento é exeqüível. Durante o tratamento ortodôntico, devido à complexidade das superfícies oclusais, o ajuste oclusal por desgaste deve ser realizado para viabilizar movimentos dentários verticais, reduzindo o tempo de tratamento. Interferências oclusais são responsáveis tanto por efeitos adversos na biomecânica, quanto por aplicação de forças excessivas, que podem causar reabsorções radiculares. Após a Ortodontia, o ajuste oclusal é um dos determinantes da estabilização dentária, devendo-se obter, para cada dente posterior, contatos oclusais "A" e "B", ou "B" e "C" no sentido vestibulolingual, além dos contatos de "parada" e "equilíbrio" no sentido mesiodistal. Os dentes anteriores passam a funcionar em movimentos mandibulares, desocluindo de imediato os dentes posteriores, o que é denominado de guia anterior, visando equilíbrio muscular e proteção do sistema estomatognático. O desgaste seletivo não deve ser utilizado como substituto da movimentação ortodôntica. OBJETIVO: apresentar os princípios relacionados ao ajuste oclusal em Ortodontia.INTRODUCTION: The knowledge of dental occlusion should be considered the basic foundation to an excellent orthodontic practice. The patient’s diagnose without the centric relation assessment can take the orthodontist to an unpleasant surprises. The use of rectangular archwires requires occlusal

  1. Ajuste do rendimento para a variação do estande em experimentos de melhoramento genético do feijão Adjustment of the yield for the stand variation in common bean genetic breeding experiments

    Directory of Open Access Journals (Sweden)

    Clause Fátima de Brum Piana

    2007-12-01

    Full Text Available O objetivo deste trabalho foi avaliar o ajuste do rendimento pela variação do estande em experimentos de feijão e propor procedimento para ajustamento por análise de co-variação. Utilizaram-se dados de 33 ambientes do Ensaio Estadual de Feijão do Rio Grande do Sul. Realizaram-se as análises de variação e de co-variação de rendimento e de estande em cada ambiente. Foram considerados quatro modelos de ajustamento alternativos: sem ajuste para a variação do estande; com ajuste para o estande médio geral; com ajuste para os estandes médios dos genótipos; e com ajuste para os estandes médios dos grupos de genótipos. Em 70% dos ambientes, ocorreu efeito linear ou quadrático significativo de estande sobre rendimento e em 85% efeito significativo de genótipo sobre estande. O efeito compensatório manifestou-se com diferentes intensidades nos ambientes. O ajuste do rendimento para a variação do estande, considerando o efeito de genótipos sobre o estande, é importante em ensaios de melhoramento do feijão. É necessário o registro de informações que permitam discriminar a origem da variação do estande.The objective of this work was to evaluate the adjustment of the yield for the stand in common bean experiments and to propose a procedure for the adjustment through covariance analysis. Data from 33 environments of the Common Bean Assay of Rio Grande do Sul State, Brazil, were used. Variance and covariance analyses of yield and stand were proceeded for each environment. Four alternative models were considered: without adjustment for stand; with adjustment for the average stand; with adjustment for the genotypes average stand; and with adjustment for the groups of genotypes average stand. Significant linear or quadratic effects of stand on yield occurred in 70% of the environments and of genotype on stand in 85%. The compensatory effect was manifested with different intensities in the environments. The adjustment of the yield

  2. Brachytherapy in childhood rhabdomyosarcoma treatment

    International Nuclear Information System (INIS)

    Novaes, Paulo Eduardo Ribeiro dos Santos

    1995-01-01

    A retrospective study of 21 children with rhabdomyosarcoma treated by brachytherapy to the primary site of the tumor at the Radiotherapy Department of the A.C.Camargo Hospital between january/1980 to june/1993 was undertaken. The main objectives were to comprove the utility of brachytherapy in childhood rhabdomyosarcoma, to evaluate the local control and survival, in association with chemotherapy, to analyze the late effects of the treatment and to determinate the preferential technique to each clinical situation. All patients received brachytherapy to the tumor site. The radioactive isotopes employed were Gold 198 , Cesium 137 and Iridium 192 . The brachytherapy techniques depended on the tumor site, period of treatment, availability of the radioactive material and stage of the disease. Patients treated exclusively by brachytherapy received 40 Gy to 60 Gy. When brachytherapy was associated with external radiotherapy the dose ranged from 20 Gy to 40 Gy. Local control was achieved in 18 of 20 patients (90%). The global survival and local control survival rates were 61.9% (13/21 patients) and 72,2% (13/18 patients) respectively. (author)

  3. American brachytherapy society (ABS) guidelines for brachytherapy of esophageal cancer

    International Nuclear Information System (INIS)

    Nag, Subir; Gaspar, Laurie; Herskovic, Arnold; Mantravadi, Prasad; Speiser, Burton

    1996-01-01

    Introduction: There is wide variation in the indications, techniques, treatment regimens and dosimetry being used to treat cancer of the esophagus and no guidelines exist for optimal therapy. Methods: The Clinical Research Committee of the ABS met to formulate consensus guidelines for brachytherapy in esophageal cancer. Results: Good candidates for brachytherapy include patients with unifocal disease, with thoracic tumor 10 cm primary regional lymph adenopathy or tumor located in the gastro-esophageal junction or cervical esophagus. Contraindications include tracheo-esophageal fistula or stenosis that cannot be by-passed. The esophageal or nasogastric tube inserted should have a diameter of 6-10 mm whenever possible. If 5FU-based chemotherapy and 50 Gy external beam (EBRT) are used, it is suggested that the low dose rate brachytherapy (LDR) dose be 20 Gy at 0.4-1 Gy/hr, prescribed at 1 cm from the source. If high dose rate (HDR) is used, the dose recommended is 10 Gy in 2 weekly fractions of 5 Gy each, given after EBRT. Chemotherapy is not usually given concurrently with brachytherapy, and when it is, the brachytherapy dose is reduced. The length of esophagus treated by brachytherapy includes the post-EBRT involved area and a 1-2 cm margin proximally and distally. Supportive care, given during EBRT includes an antifungal agent (e.g., diflucan) and carafate. Gradual dilatation of the esophagus is required post-treatment for esophageal strictures. Conclusion: Guidelines were developed for brachytherapy in esophageal cancer. As more clinical data becomes available, these guidelines will be updated by the ABS

  4. Specification of brachytherapy sources

    Energy Technology Data Exchange (ETDEWEB)

    1984-10-01

    BCRU recommends that the following specification of gamma-ray brachytherapy sources be adopted. Unless otherwise stated, the output of a cylindrical source should be specified in air kerma rate at a point in free space at a distance of 1 m from the source on the radial plane of symmetry, i.e. the plane bisecting the active length and perpendicular to the cylindrical axis of the source. For a wire source the output should be specified for a 1 cm length. For any other construction of source, the point at which the output is specified should be stated. It is also recommended that the units in which the air kerma rate is expressed should be micrograys per hour (..mu..Gy/h).

  5. Radiotherapy and brachytherapy

    International Nuclear Information System (INIS)

    2007-02-01

    This presentation first defines the radiotherapy and brachytherapy techniques, indicates the used ionizing radiations (electromagnetic and particles), describes the mechanisms and processes of action of ionizing radiations: they can be physical by photon-matter interactions (Compton effect and photoelectric effect) or due to electron-matter interactions (excitation, ionization), physical-chemical by direct or indirect action (DNA damage), cellular (mitotic or apoptotic death), tissue (sane and tumorous tissues and differential effect). It discusses the biological efficiency of these treatments which depends on different parameters: intrinsic radio-sensitivity, time (session fractioning and organisation in time), oxygen, radiation quality, cellular cycle, dose rate, temperature. It presents the different types of radiotherapy: external radiotherapy (general sequence, delineation, dosimetry, protection of critical organs, treatment session, quality control, monitoring consultation) and briefly presents some specific techniques (total body irradiation, total cutaneous electron therapy, pre-operation radiotherapy, radio-surgery, hadron-therapy). It proposes an overview of the main indications for this treatment: brain tumours, upper aero digestive tract tumours, bronchial tumours, oesophagus, stomach and pancreas tumours, breast tumours, cervix cancer, rectum tumour, and so on, and indicates the possible associated treatments. The next part addresses brachytherapy. It presents the principles and comments the differences with radiotherapy. It indicates the used radio-elements (Caesium 137, Iridium 192, Iodine 125), describes the implementation techniques (plastic tubes, use of iodine 125, intracavitary and endo-luminal radiation therapy). It proposes an overview of the different treated tumours (skin, breast, prostates, bronchial, oesophagus, ENT) and indicates possible early and late secondary effects for different organs

  6. DO INCENTIVO À CRIMINALIZAÇÃO: OS TERMOS DE AJUSTE DE CONDUTA NA ORIZICULTURA EM SANTA CATARINA - BRASIL

    Directory of Open Access Journals (Sweden)

    Alfredo Celso Fantini

    2014-03-01

    Full Text Available Em Santa Catarina os Termos de Ajuste de Conduta (TACs vêm ganhando espaço como estratégia para garantir, na zona rural, a recuperação de áreas de preservação permanente, principalmente as matas ciliares. No caso dos plantadores de arroz a situação é, no mínimo, discutível: agricultores antes incentivados pelo Estado a usarem para a produção toda a área de várzea, até o limite dos rios, são obrigados agora a recuperarem a vegetação ciliar “que nunca deveria ter sido suprimida”. Ignorando a complexidade da questão, o Ministério Público adotou o comando e controle para resolver “o problema”. Passados três anos, quase nada aconteceu na prática. Neste artigo, usamos uma abordagem sistêmica para compreender a situação-problema e apontar encaminhamentos para a sua melhoria. Em um estudo de caso realizado em Jacinto Machado-SC, foram utilizados métodos qualitativos e quantitativos (análise documental, entrevistas, inventários e oficinas e principalmente a Soft System Methodology (SSM. Os resultados revelaram que a mata ciliar é só mais um elemento de um complexo sistema de interesses, onde fatores sociais, culturais, ambientais e econômicos interagem dinamicamente. Apontam, também, a necessidade de uma aproximação entre os interessados na situação-problema para tornar possível uma acomodação entre as diferentes visões de mundo dos envolvidos

  7. El ajuste de plantillas: el papel de los despidos por causas objetivas

    OpenAIRE

    Castillo Lorenzo, Jesús

    2016-01-01

    Este estudio académico sobre el ajuste de plantillas en las empresas lo he redactado, centrándome en los ajustes que se realizan por despidos por causas objetivas,que en la mayoría de los casos son despidos económicos. El trabajo que he desarrollado me parece un trabajo interesante, porque trata un tema actual como es la crisis económica y social que padece España y los países de la UE. Me agrada haber tratado este tema,porque me interesa la legislación la...

  8. Erectile function after prostate brachytherapy

    International Nuclear Information System (INIS)

    Merrick, Gregory S.; Butler, Wayne M.; Wallner, Kent E.; Galbreath, Robert W.; Anderson, Richard L.; Kurko, Brian S.; Lief, Jonathan H.; Allen, Zachariah A.

    2005-01-01

    Purpose: To evaluate erectile function after permanent prostate brachytherapy using a validated patient-administered questionnaire and to determine the effect of multiple clinical, treatment, and dosimetric parameters on penile erectile function. Methods and materials: A total of 226 patients with preimplant erectile function determined by the International Index of Erectile Function (IIEF) questionnaire underwent permanent prostate brachytherapy in two prospective randomized trials between February 2001 and January 2003 for clinical Stage T1c-T2c (2002 American Joint Committee on Cancer) prostate cancer. Of the 226 patients, 132 were potent before treatment and, of those, 128 (97%) completed and returned the IIEF questionnaire after brachytherapy. The median follow-up was 29.1 months. Potency was defined as an IIEF score of ≥13. The clinical, treatment, and dosimetric parameters evaluated included patient age; preimplant IIEF score; clinical T stage; pretreatment prostate-specific antigen level; Gleason score; elapsed time after implantation; preimplant nocturnal erections; body mass index; presence of hypertension or diabetes mellitus; tobacco consumption; the volume of the prostate gland receiving 100%, 150%, and 200% of the prescribed dose (V 100/150/200 ); the dose delivered to 90% of the prostate gland (D 90 ); androgen deprivation therapy; supplemental external beam radiotherapy (EBRT); isotope; prostate volume; planning volume; and radiation dose to the proximal penis. Results: The 3-year actuarial rate of potency preservation was 50.5%. For patients who maintained adequate posttreatment erectile function, the preimplant IIEF score was 29, and in patients with brachytherapy-related ED, the preimplant IIEF score was 25. The median time to the onset of ED was 5.4 months. After brachytherapy, the median IIEF score was 20 in potent patients and 3 in impotent patients. On univariate analysis, the preimplant IIEF score, patient age, presence of nocturnal

  9. Afectividad inducida e impacto en la creatividad, crecimiento personal después del cambio y ajuste percibido al narrar una experiencia emocional intensa

    Directory of Open Access Journals (Sweden)

    Silvia da Costa

    2015-05-01

    Full Text Available Se examinan en un estudio experimental los efectos de la inducción de afectividad positiva en la creatividad y la importancia de las emociones como variables mediadoras. Se indujo alta y baja afectividad positiva pidiendo a las personas participantes que redactaran tres poemas haikus sobre dos estímulos de connotación positiva, alta (N = 28 y baja (N = 28. Las personas escribieron sobre su experiencia de enamoramiento más intenso y contestaron una escala sobre las emociones sentidas al redactar el texto, una medida de crecimiento personal y una tercera referida a la obtención de metas adaptativas después del episodio. En la condición de alta afectividad positiva se informó de más emociones positivas y menos negativas al narrar la experiencia, un mayor crecimiento personal y un mayor ajuste. Jueces independientes evaluaron como más originales el último poema y la narración de la experiencia en la condición de alta afectividad positiva. Un análisis mediacional mostró que las emociones positivas explicaban la influencia de la manipulación sobre el crecimiento personal y el ajuste percibido.

  10. Análisis de los factores de ajuste por utilización de carril en intersecciones semaforizadas de Bogotá D. C.

    Directory of Open Access Journals (Sweden)

    Ricardo José Peña Lindarte

    2010-01-01

    Full Text Available Este artículo está basado en el planteamiento metodológico desarrollado en el Manual de Capacidad de Carreteras de Estados Unidos (HCM - Highway Capacity Manual, de la Transportation Research Board (TRB, para el análisis de capacidad y niveles de servicio en intersecciones semaforizadas, asociado al factor de ajuste por utilización de carril (fLU, que corresponde a uno de los once factores de ajuste propuestos en la metodología de cálculo, en el módulo de intensidades de saturación. La estimación del factor fLU plantea la definición de una metodología teniendo en cuenta las condiciones operacionales de intersecciones se- maforizadas en Bogotá D. C. a partir del análisis de las corrientes vehiculares, que incluye caracterización vial y del tránsito, con base en muestreos estadísticos, toma y procesamiento de información de campo y análisis de datos. El estudio establece, entre otros aspectos, ecuaciones que permiten obtener datos referenciales para la determinación de factores de ajuste por utilización de carril en vías de Bogotá en función de las tipologías de los accesos y el volumen vehicular prevaleciente para el análisis de intersecciones semaforizadas; por ejemplo, para el caso específico de vías con accesos de dos carriles directos (2CCD la ecuación básica determinada fue y=-3,03E-08X2+3,44E-05X+0,888988, con coeficiente de correlación igual a 1,0, donde la variable dependiente y corresponde al factor fLU y la variable independiente X es el volumen en vehículos mixtos/hora, ecuación considerada estadísticamente significativa. Finalmente, se presenta el análisis comparativo de los factores de ajuste por utilización de carril estimados en el estudio, comparando los valores recomendados por el HCM, sustentándose así las conclusiones y recomendaciones, de las cuales se extracta la validación de los factores recomendados por el HCM, y se propone utilizar para los proyectos de diseño y planeamiento semaf

  11. La industria manufacturera en Centroamérica: Perspectivas del Ajuste a la nueva política comercial regional

    Directory of Open Access Journals (Sweden)

    Fernando RUEDA-JUNQUERA

    2009-11-01

    Full Text Available RESUMEN: La nueva política comercial del Mercado Común Centroamericano está dando lugar a cambios en los flujos comerciales, que inducirán un ajuste inter-/intraindustrial en el sector manufacturero regional. Este artículo presenta y analiza los principales resultados de un estudio empírico que evaluó el impacto del nuevo programa de integración regional en el patrón de especialización y comercio de manufacturas de cada país miembro. El enfoque empírico empleado conllevó la construcción de hojas de balance que integraron en una base comparable los datos de producción y comercio para el sector manufacturero de cada país. Asimismo, se obtuvieron dos grupos de ratios que midieron respectivamente, la importancia relativa de los mercados regional y mundial para los subsectores manufactureros de cada país, y el potencial de éstos para una especialización inter-/intraindustrial en los dos mercados.ABSTRACT: The new trade policy in the Central American Common Market is given rise to changes in trade flows that will induce an inter-/intraindustry adjustment in the regional manufacturing sector. This article presents and analyses the main results of an empirical study which assessed the impact of the new integration scheme on each member country's pattern of trade and specialisation in manufactures. The empirical approach used in the study involved the construction of balance sheets integrating production and trade data on a comparable basis for each country's manufacturing sector. Likewise, two groups of ratios were obtained. They measured respectively, the relative importance of the regional and world market for the manufacturing subsectors of each country and the subsectoral potential for an inter-/intraindustry specialisation in the two markets.

  12. Dosimetry in intravascular brachytherapy

    International Nuclear Information System (INIS)

    Campos, Laelia Pumilla Botelho

    2000-03-01

    Among the cardiovascular diseases responsible for deaths in the adult population in almost all countries of the world, the most common is acute myocardial infarction, which generally occurs because of the occlusion of one or more coronary arteries. Several diagnostic techniques and therapies are being tested for the treatment of coronary artery disease. Balloon angioplasty has been a popular treatment which is less invasive than traditional surgeries involving revascularization of the myocardium, thus promising a better quality of life for patients. Unfortunately, the rate of restenosis (re-closing of the vessel) after balloon angioplasty is high (approximately 30-50% within the first year after treatment).Recently, the idea of delivering high radiation doses to coronary arteries to avoid or delay restenosis has been suggested. Known as intravascular brachytherapy, the technique has been used with several radiation sources, and researchers have obtained success in decreasing the rate of restenosis in some patient populations. In order to study the radiation dosimetry in the patient and radiological protection for the attending staff for this therapy, radiation dose distributions for monoenergetic electrons and photons (at nine discrete energies) were calculated for blood vessels of diameter 0.15, o,30 and 0.45 cm with balloon and wire sources using the radiation transport code MCNP4B. Specific calculations were carried out for several candidate radionuclides as well. Two s tent sources (metallic prosthesis that put inside of patient's artery through angioplasty) employing 32 P are also simulated. Advantages and disadvantages of the various radionuclides and source geometries are discussed. The dosimetry developed here will aid in the realization of the benefits obtained in patients for this promising new technology. (author)

  13. El papel de la categorización social y las diferencias sociodemográficas en la autoestima, el ajuste y el bienestar psicológicos de una muestra de inmigrantes

    Directory of Open Access Journals (Sweden)

    José Andrés Peña-Pinzón

    2014-05-01

    Full Text Available Se explora el efecto de la saliencia de la categorización social inmigrante y su interacción con diferencias sociodemográficas (nivel de estudios, situación laboral, sexo de los sujetos, en ajuste psicológico, bienestar psicológico y autoestima. 210 inmigrantes de origen sudamericano, residentes en las provincias de Granada y Almería, fueron distribuidos en dos condiciones experimentales: "saliencia baja/alta de la categorización social inmigrante". Encontramos efecto de la manipulación sobre las medidas de pertenencia e identidad (autoestima colectiva, autoestima individual, ansiedad (SA-45 y bienestar laboral. Cuando la saliencia de la categorización social es baja (vs. alta, los sujetos presentan mejor autoestima, menos ansiedad y menos bienestar laboral. El sexo se asocia con la manipulación experimental en las escalas privada y pública (autoestima colectiva y en somatización, depresión y ansiedad (SA45. Los hombres para los que es menos saliente su condición de inmigrante presentan resultados más óptimos. El nivel de estudios y la situación laboral se asocian con ajuste psicológico: los sujetos sin trabajo (vs. los que están trabajando y los de estudios básicos o sin estudios (vs. los de estudios medios o superiores presentan peor ajuste.

  14. About brachytherapy for the handling of cancer

    International Nuclear Information System (INIS)

    Campos, Tarcisio P.R.; Silva, Nilton O.; Damaso, Renato S.; Costa, Helder R.; Borges, Paulo H.R.; Mendes, Bruno M.

    2000-01-01

    The technique of brachytherapy is argued in this article. The 'hardware' and 'necessary software' for the handling are summarily presented. Being the macro-dosimetry an important stage in the radiation therapy procedure, a simplified method of doses evaluation in conventional brachytherapy is presented. In an illustrative form, isodoses of a three-dimensional distribution of linear sources are drawn on a digitalized X-ray picture, exemplifying the handling of breast brachytherapy by sources of iridium

  15. El ajuste entre la estrategia competitiva y la estrategia de innovación tecnológica: Su implicación en el resultado de la empresa

    OpenAIRE

    González Moreno, Ángela

    2011-01-01

    A pesar de la importancia de la innovación tecnológica en la obtención de la ventaja competitiva, las relaciones entre la estrategia competitiva y la estrategia de innovación no han sido tratadas en profundidad. Esta tesis pone de manifiesto la necesidad del buen acoplamiento entre estos dos tipos de estrategia, proporcionando evidencia empírica acerca de como el ajuste entre ambas repercute positivamente en el resultado. El análisis aplicado a empresas del sector industrial de la electrón...

  16. El papel de la categorización social y las diferencias sociodemográficas en la autoestima, el ajuste y el bienestar psicológicos de una muestra de inmigrantes

    OpenAIRE

    José Andrés Peña-Pinzón; Carmen Gómez-Berrocal; Antonio Fernández-Parra

    2014-01-01

    Se explora el efecto de la saliencia de la categorización social inmigrante y su interacción con diferencias sociodemográficas (nivel de estudios, situación laboral, sexo) de los sujetos, en ajuste psicológico, bienestar psicológico y autoestima. 210 inmigrantes de origen sudamericano, residentes en las provincias de Granada y Almería, fueron distribuidos en dos condiciones experimentales: "saliencia baja/alta de la categorización social inmigrante". Encontramos efecto de la manipulación sobr...

  17. Validez del modelo bidimensional de socialización parental en diferentes entornos sociales de la cultura española : implicaciones para el ajuste psicosocial de los adolescentes

    OpenAIRE

    Fuentes Durán, María del Castillo

    2014-01-01

    Durante las últimas décadas, la literatura empírica ha demostrado en repetidas ocasiones la influencia que tienen las diferentes formas de actuación de los padres en el proceso de socialización en el ajuste psicológico y social de los hijos. La investigación en torno a la socialización familiar se ha basado tradicionalmente en el modelo teórico de dos grandes dimensiones teóricamente independientes (aceptación/implicación y severidad/imposición, Darling y Steinberg, 1993; Maccoby y Martin...

  18. ¿Existe rigidez en el ajuste del empleo en Chile?

    Directory of Open Access Journals (Sweden)

    Jorge Dresdner

    2017-01-01

    Full Text Available Antecedentes: Estudiamos c mo el nivel de empleo agregado se ajust en la eco- nom a chilena, posterior a la llamada crisis asi tica. Contrastamos distintas hi- p tesis que se han esgrimido en el debate p blico, y que no han sido probadas formalmente, sobre las razones por las cuales el nivel de empleo tard tanto tiempo en recuperar los niveles precrisis. M todos: Especi camos y estimamos un modelo de vectores autorregresivos con series de tiempo para el trimestre 1995.1-2007.4 y aplicamos el m todo de Jo- hansen para identi car vectores de cointegraci n. Resultados: Estimamos un vector de cointegraci n que representa la funci n de demanda laboral. Realizamos las siguientes pruebas de hip tesis sobre esta fun- ci n: homogeneidad de grado cero en precios, elasticidad producto de la de- manda unitaria; quiebre estructural en el intercepto de esta funci n; cambio en la elasticidad producto de la demanda laboral de largo plazo entre subperiodos y existencia de costos de ajuste. Conclusiones: Inestabilidad en la elasticidad demanda del ingreso en la funci n de demanda por trabajo en Chile posterior a la crisis asi tica, pero no en la direc- ci n sugerida por el debate previo. Adicionalmente, el factor que contribuy en forma m s decisiva a la lenta recuperaci n del empleo posterior a la crisis fue el costo de ajuste presentes en la econom a chilena.

  19. Comparación entre Factores de Ajuste Multiplicativos y Aditivos para Producción por Lactancia en un Hato Holstein

    Directory of Open Access Journals (Sweden)

    Arboleda Zapata Elkin Mauricio

    1995-09-01

    Full Text Available La presente investigación se efectuó a partir de 558 registros de lactancia tomados del hato Holstein Paysandú el cual está situado en el corregimiento Santa Elena de Medellín en una zona ecológica de bosque húmedo montano bajo (bh-MB y pertenece a la Facultad de Ciencias Agropecuarias de la Universidad Nacional de Colombia, Sede Medellín. El objetivo propuesto fué determinar las ventajas comparativas entre factores de ajuste multiplicativos y aditivos para producción por lactancia. Para ello se trabajó con datos ajustados a 305 días, en vista de la muy alta significancia observada para el efecto duración de la lactancia. Después de confirmar por medio del programa de mínimos cuadrados de Harvey, 1988, que los factores medio-ambientales más influyentes sobre la producción ajustada a 305 días son el año de parto, los días abiertos previos y el número de partos (P£0.01, así como la edad y la época de parto (P£0.05, se procedió a ajustar por estos efectos mediante factores de corrección multiplicativos y aditivos. Inicialmente se utilizó como base la subclase de máxima producción para cada efecto y a ellas fueron llevados los demás registros; luego se obtuvieron factores aditivos mediante el uso de constantes estimadas por el programa Harvey y multiplicativos a partir de la media de mínimos cuadrados. Una vez ajustados los datos se corrió nuevamente el modelo inicial, con el fin de cuantificar la varianza residual presente tanto para factores de ajuste multiplicativos como aditivos, a los dos niveles propuestos. La comparación se realizó mirando las relaciones de la tabla F y las varianzas residuales entre grupos y dentro de ellos. Aunque no se presentaron diferencias marcadas, se observa que, en general los factores de ajuste aditivos tuvieron un mejor comportamiento que los multiplicativos, pues con el empleo de estos últimos queda una pequeña variación sin remover; en tanto que con factores de ajuste

  20. Physical aspects of radioisotope brachytherapy

    International Nuclear Information System (INIS)

    1967-01-01

    The present report represents an attempt to provide, within a necessarily limited compass, an authoritative guide to all important physical aspects of the use of sealed gamma sources in radiotherapy. Within the report, reference is made wherever necessary to the more extensive but scattered literature on this subject. While this report attempts to cover all the physical aspects of radioisotope 'brachytherapy' it does not, of course, deal exhaustively with any one part of the subject. 384 refs, 3 figs, 6 tabs

  1. Rectourethral fistula following LDR brachytherapy.

    Science.gov (United States)

    Borchers, Holger; Pinkawa, Michael; Donner, Andreas; Wolter, Timm P; Pallua, Norbert; Eble, Michael J; Jakse, Gerhard

    2009-01-01

    Modern LDR brachytherapy has drastically reduced rectal toxicity and decreased the occurrence of rectourethral fistulas to <0.5% of patients. Therefore, symptoms of late-onset sequelae are often ignored initially. These fistulas cause severe patient morbidity and require interdisciplinary treatment. We report on the occurrence and management of a rectourethral fistula which occurred 4 years after (125)I seed implantation. Copyright 2009 S. Karger AG, Basel.

  2. Radiation safety and gynaecological brachytherapy

    International Nuclear Information System (INIS)

    Crawford, L.

    1985-01-01

    In 1983, the Radiation Control Section of the South Australian Health Commission conducted an investigation into radiation safety practices in gynaecological brachytherapy. Part of the investigation included a study of the transportation of radioactive sources between hospitals. Several deficiences in radiation safety were found in the way these sources were being transported. New transport regulations came into force in South Australia in July 1984 and since then there have been many changes in the transportation procedure

  3. Intravascular brachytherapy for peripheral vascular disease

    Directory of Open Access Journals (Sweden)

    Hagen, Anja

    2008-09-01

    Full Text Available Scientific background: Percutaneous transluminal angioplasties (PTA through balloon dilatation with or without stenting, i.e. vessel expansion through balloons with or without of implantation of small tubes, called stents, are used in the treatment of peripheral artery occlusive disease (PAOD. The intravascular vessel irradiation, called intravascular brachytherapy, promises a reduction in the rate of repeated stenosis (rate of restenosis after PTA. Research questions: The evaluation addresses questions on medical efficacy, cost-effectiveness as well as ethic, social and legal implications in the use of brachytherapy in PAOD patients. Methods: A systematic literature search was conducted in August 2007 in the most important medical electronic databases for publications beginning from 2002. The medical evaluation included randomized controlled trials (RCT. The information synthesis was performed using meta-analysis. Health economic modeling was performed with clinical assumptions derived from the meta-analysis and economical assumptions derived from the German Diagnosis Related Groups (G-DRG-2007. Results: Medical evaluation: Twelve publications about seven RCT on brachytherapy vs. no brachytherapy were included in the medical evaluation. Two RCT showed a significant reduction in the rate of restenosis at six and/or twelve months for brachytherapy vs. no brachytherapy after successful balloon dilatation, the relative risk in the meta-analysis was 0.62 (95% CI: 0.46 to 0.84. At five years, time to recurrence of restenosis was significantly delayed after brachytherapy. One RCT showed a significant reduction in the rate of restenosis at six months for brachytherapy vs. no brachytherapy after PTA with optional stenting, the relative risk in the meta-analysis was 0.76 (95% CI: 0.61 to 0.95. One RCT observed a significantly higher rate of late thrombotic occlusions after brachytherapy in the subgroup of stented patients. A single RCT for brachytherapy

  4. Risk analysis of brachytherapy events

    International Nuclear Information System (INIS)

    Buricova, P.; Zackova, H.; Hobzova, L.; Novotny, J.; Kindlova, A.

    2005-01-01

    For prevention radiological events it is necessary to identify hazardous situation and to analyse the nature of committed errors. Though the recommendation on the classification and prevention of radiological events: Radiological accidents has been prepared in the framework of Czech Society of Radiation Oncology, Biology and Physics and it was approved by Czech regulatory body (SONS) in 1999, only a few reports have been submitted up to now from brachytherapy practice. At the radiotherapy departments attention has been paid more likely to the problems of dominant teletherapy treatments. But in the two last decades the usage of brachytherapy methods has gradually increased because .nature of this treatment well as the possibilities of operating facility have been completely changed: new radionuclides of high activity are introduced and sophisticate afterloading systems controlled by computers are used. Consequently also the nature of errors, which can occurred in the clinical practice, has been changing. To determine the potentially hazardous parts of procedure the so-called 'process tree', which follows the flow of entire treatment process, has been created for most frequent type of applications. Marking the location of errors on the process tree indicates where failures occurred and accumulation of marks along branches show weak points in the process. Analysed data provide useful information to prevent medical events in brachytherapy .The results strength the requirements given in Recommendations of SONS and revealed the need for its amendment. They call especially for systematic registration of the events. (authors)

  5. Definitive Brachytherapy for Kaposi's Sarcoma

    International Nuclear Information System (INIS)

    Williams, A.; Ezzell, G.; Zalupski, M.; Fontanesi, J.

    1996-01-01

    Purpose: To assess the efficacy and possible complications in patients diagnosed with Kaposi's sarcoma and treated with definitive brachytherapy. Methods and Materials: Between January, 1995 and December, 1995, four patients with Kaposi's sarcoma (KS) were treated with brachytherapy. Three patients, all with positive HIV status were treated using Iridium 192 (Ir-192) sources via a high-dose rate remote afterloader. One patient with endemic KS was treated using the application of catheters loaded with Californium 252. Eight sites were treated and included scalp, feet, nose, penis, hand, neck, and back. Dose rate for Ir-192 was 330cGy/fx to a total dose of 990cGy. The Californium was delivered as 100nGy/b.i.d. to a total dose of 900nGy. Follow-up as ranged from 2-6 months. Results: All four patients remain alive. Seven of eight sites have had complete clinical response and each patient has reported durable pain relief that has not subsided through last follow-up of 1/96. Two of eight sites, both treated with surface mold technique with Californium 252 developed moist desquamation. The remaining six sites did not demonstrate significant toxicity. Conclusion: Brachytherapy can offer Kaposi's sarcoma patients results that are equivalent to external beam radiation therapy, with minimal complications, a shorter treatment time and potential cost effectiveness

  6. Ajustes nos movimentos de alcançar e apreender objetos: impacto da Síndrome de Down Adjustments in the movements of reaching for and grasping objects: the impact of Down Syndrome

    Directory of Open Access Journals (Sweden)

    Mariana Martins dos Santos

    2012-06-01

    Full Text Available OBJETIVOS: verificar a influência das propriedades dos objetos nos ajustes realizados por lactentes típicos e com Síndrome de Down (SD dos quatro aos oito meses de idade ao alcançar e apreender objetos. MÉTODOS: 16 lactentes, avaliados uma vez ao mês dos 4 aos 8 meses, sendo oito típicos e oito com SD. Quatro objetos esféricos (maleável grande, maleável pequeno, rígido grande e rígido pequeno foram apresentados, e os cinco primeiros movimentos válidos foram registrados para análise das variáveis: ajuste proximal (uni e bimanual, ajuste distal (orientação da palma, abertura da mão e apreensão do objeto. RESULTADOS: os lactentes típicos apresentaram mais ajuste bimanual para objetos grandes aos seis e oito meses e os com SD aos sete meses. Quanto aos ajustes distais, os lactentes típicos variaram seu comportamento enquanto os com SD apresentaram uso predominante da posição oblíqua. Em geral, o grupo típico apresentou maior sucesso na apreensão dos objetos rígidos e maleável pequeno quando comparados aos lactentes com SD. CONCLUSÕES: Os lactentes com SD apresentaram menor variedade de ajustes o que levou a um menor sucesso na apreensão, possivelmente devido a restrições intrínsecas da SD.OBJECTIVES: to verify the influence that properties of objects have on the reaching and grasping adjustments made by infants with and without Down syndrome (DS between four to eight months of age. METHODS: 16 infants, eight typical and eight with DS, were evaluated once a month from months 4 to 8. Four spherical objects (large soft, small soft, large hard and small hard were offered and the first five valid movements were recorded for analysis of the variables: proximal adjustment (uni- and bimanual, distal adjustments (palm orientation, hand opening and grasping of the object. RESULTS: the typical infants displayed greater bimanual adjustment for large objects at six and eight months and those with DS at seven months. As for distal

  7. Ajuste de modelos de platô de resposta via regressão isotônica Response plateau models fitting via isotonic regression

    Directory of Open Access Journals (Sweden)

    Renata Pires Gonçalves

    2012-02-01

    Full Text Available Dentro do contexto nutricional, a suplementação de microminerais em rações para aves frequentemente é feita em quantidades superiores às exigidas na tentativa de assegurar o bom desempenho dos animais. Os experimentos do tipo dose resposta são muito comuns na determinação de níveis ótimos dos nutrientes na ração e contemplam a utilização de modelos de regressão para atingir tal objetivo. Porém, na análise de regressão usual, geralmente, não se usa uma informação a priori sobre uma possível relação de ordem na variável resposta. A regressão isotônica é um método de estimação por mínimos quadrados que gera estimativas que satisfazem a mesma ordenação dos dados. Na teoria da regressão isotônica, essa informação é utilizada de forma essencial e espera-se que a eficiência do ajuste seja aumentada quando se faz uso dela. Diante do exposto, o presente trabalho tem como objetivo utilizar uma metodologia de regressão isotônica, como uma forma alternativa para analisar dados de deposição de zinco (Zn na tíbia de aves machos da linhagem Hubbard. No estudo, foram considerados os modelos de platô de resposta polinomial quadrático e não linear exponencial. Além desses modelos, também foi proposto o ajuste de um modelo logarítmico para os dados e a eficiência da metodologia foi avaliada por meio de um estudo de simulação Monte Carlo, considerando diferentes cenários para os valores paramétricos. A isotonização dos dados propiciou uma melhora em todos os avaliadores de qualidade de ajuste considerados no trabalho. Dentre os modelos utilizados, o logarítmico apresentou estimativas dos parâmetros mais coerentes com os valores relatados na literatura, para os dados de deposição de Zn na tíbia de aves machos.Within the nutritional context, the supplementation of microminerals in bird food is often made in quantities exceeding those required in the attempt to ensure the proper performance of the animals

  8. Interstitial prostate brachytherapy. LDR-PDR-HDR

    International Nuclear Information System (INIS)

    Kovacs, Gyoergy; Hoskin, Peter

    2013-01-01

    The first comprehensive overview of interstitial brachytherapy for the management of local or locally advanced prostate cancer. Written by an interdisciplinary team who have been responsible for the successful GEC-ESTRO/EAU Teaching Course. Discusses in detail patient selection, the results of different methods, the role of imaging, and medical physics issues. Prostate brachytherapy has been the subject of heated debate among surgeons and the proponents of the various brachytherapy methods. This very first interdisciplinary book on the subject provides a comprehensive overview of innovations in low dose rate (LDR), high dose rate (HDR), and pulsed dose rate (PDR) interstitial brachytherapy for the management of local or locally advanced prostate cancer. In addition to detailed chapters on patient selection and the use of imaging in diagnostics, treatment guidance, and implantation control, background chapters are included on related medical physics issues such as treatment planning and quality assurance. The results obtained with the different treatment options and the difficult task of salvage treatment are fully discussed. All chapters have been written by internationally recognized experts in their fields who for more than a decade have formed the teaching staff responsible for the successful GEC-ESTRO/EAU Prostate Brachytherapy Teaching Course. This book will be invaluable in informing residents and others of the scientific background and potential of modern prostate brachytherapy. It will also prove a useful source of up-to-date information for those who specialize in prostate brachytherapy or intend to start an interstitial brachytherapy service.

  9. Um Estudo sobre a Governança Corporativa e o Nível de Atendimento aos Critérios de Evidenciação do Ajuste a Valor Presente em Empresas de Construção e Transporte

    Directory of Open Access Journals (Sweden)

    Juliana Gonçalves de Araújo

    2015-08-01

    Full Text Available Esta pesquisa tem como objetivo verificar a relação do nível de governança com o atendimento aos critérios de evidenciação dispostos no CPC 12, referente às práticas do Ajuste a Valor Presente, nas empresas do setor de Construção e Transporte listadas na BM&FBovespa entre os anos de 2008 a 2012. No entanto, foram excluídas algumas empresas, por estas não apresentarem indícios, em quaisquer dos anos, da realização do Ajuste a Valor Presente. Assim, a amostra deste estudo foi composta por 72 companhias, as quais evidenciaram, seja em Nota Explicativa ou em conta de Balanço Patrimonial, indício da prática de Ajuste a Valor Presente. Foi possível verificar que as divulgações realizadas estão aquém das propostas pelo CPC 12, e que as mudanças ocorridas no processo de ajuste são pouco divulgadas, constituindo um cenário que pouco se modifica. O único item que sofreu uma grande elevação de atendimento foi o da divulgação das práticas gerais de Ajuste a Valor Presente em Notas Explicativas, principalmente no ano de 2010, devido à compulsoriedade da aplicação das normas contábeis nas entidades de capital aberto. O item que menos foi atendido referiu-se à evidenciação dos modelos de cálculos para aplicação do Ajuste a Valor Presente. Apesar da descrição do item objeto do Ajuste a Valor Presente ter grande representatividade, as entidades ainda necessitam divulgar melhor as premissas, montante e horizonte temporal destes. Também foi possível observar, através do uso do teste Exato de Fisher, uma relação entre o nível de governança e o nível de atendimento, onde aquelas que pertencem ao Novo Mercado se apresentam mais propensas a evidenciar melhor suas informações, enquanto as que não estão enquadradas nos níveis de governança apresentam um nível de atendimento insatisfatório.

  10. High dose rate brachytherapy for oral cancer

    International Nuclear Information System (INIS)

    Yamazaki, Hideya; Yoshida, Ken; Yoshioka, Yasuo; Shimizutani, Kimishige; Koizumi, Masahiko; Ogawa, Kazuhiko; Furukawa, Souhei

    2013-01-01

    Brachytherapy results in better dose distribution compared with other treatments because of steep dose reduction in the surrounding normal tissues. Excellent local control rates and acceptable side effects have been demonstrated with brachytherapy as a sole treatment modality, a postoperative method, and a method of reirradiation. Low-dose-rate (LDR) brachytherapy has been employed worldwide for its superior outcome. With the advent of technology, high-dose-rate (HDR) brachytherapy has enabled health care providers to avoid radiation exposure. This therapy has been used for treating many types of cancer such as gynecological cancer, breast cancer, and prostate cancer. However, LDR and pulsed-dose-rate interstitial brachytherapies have been mainstays for head and neck cancer. HDR brachytherapy has not become widely used in the radiotherapy community for treating head and neck cancer because of lack of experience and biological concerns. On the other hand, because HDR brachytherapy is less time-consuming, treatment can occasionally be administered on an outpatient basis. For the convenience and safety of patients and medical staff, HDR brachytherapy should be explored. To enhance the role of this therapy in treatment of head and neck lesions, we have reviewed its outcomes with oral cancer, including Phase I/II to Phase III studies, evaluating this technique in terms of safety and efficacy. In particular, our studies have shown that superficial tumors can be treated using a non-invasive mold technique on an outpatient basis without adverse reactions. The next generation of image-guided brachytherapy using HDR has been discussed. In conclusion, although concrete evidence is yet to be produced with a sophisticated study in a reproducible manner, HDR brachytherapy remains an important option for treatment of oral cancer. (author)

  11. High dose rate brachytherapy for oral cancer.

    Science.gov (United States)

    Yamazaki, Hideya; Yoshida, Ken; Yoshioka, Yasuo; Shimizutani, Kimishige; Furukawa, Souhei; Koizumi, Masahiko; Ogawa, Kazuhiko

    2013-01-01

    Brachytherapy results in better dose distribution compared with other treatments because of steep dose reduction in the surrounding normal tissues. Excellent local control rates and acceptable side effects have been demonstrated with brachytherapy as a sole treatment modality, a postoperative method, and a method of reirradiation. Low-dose-rate (LDR) brachytherapy has been employed worldwide for its superior outcome. With the advent of technology, high-dose-rate (HDR) brachytherapy has enabled health care providers to avoid radiation exposure. This therapy has been used for treating many types of cancer such as gynecological cancer, breast cancer, and prostate cancer. However, LDR and pulsed-dose-rate interstitial brachytherapies have been mainstays for head and neck cancer. HDR brachytherapy has not become widely used in the radiotherapy community for treating head and neck cancer because of lack of experience and biological concerns. On the other hand, because HDR brachytherapy is less time-consuming, treatment can occasionally be administered on an outpatient basis. For the convenience and safety of patients and medical staff, HDR brachytherapy should be explored. To enhance the role of this therapy in treatment of head and neck lesions, we have reviewed its outcomes with oral cancer, including Phase I/II to Phase III studies, evaluating this technique in terms of safety and efficacy. In particular, our studies have shown that superficial tumors can be treated using a non-invasive mold technique on an outpatient basis without adverse reactions. The next generation of image-guided brachytherapy using HDR has been discussed. In conclusion, although concrete evidence is yet to be produced with a sophisticated study in a reproducible manner, HDR brachytherapy remains an important option for treatment of oral cancer.

  12. Curvas de Lactação em Rebanhos da Raça Holandesa no Estado de Minas Gerais: Escolha do Modelo de Melhor Ajuste

    Directory of Open Access Journals (Sweden)

    Gonçalves Tarcísio de Moraes

    2002-01-01

    Full Text Available Para selecionar o modelo de curva de lactação de melhor ajuste aos dados de produção de leite no dia de controle de animais da raça Holandesa no Estado de Minas Gerais, utilizaram-se 157.932 controles de 17.150 lactações, de 1990 a 1996, do arquivo inicial com 305.506 controles de 56.422 lactações, do Serviço de Controle Leiteiro da ACGHMG. Ajustaram-se os dados para os fatores: região, nível de produção, ano-estação de parto, classes de ordem e idade ao parto (COPI, grupo genético, número de controles e interações, além dos efeitos linear e quadrático da duração da lactação. Para verificar o melhor ajuste aos modelos Quadrático logarítmico, Gamma Incompleta, Regressão Múltipla e Multifásico (Monofásico e difásico, foram usados menor desvio padrão residual, R² ajustado ao número de parâmetros das equações, autocorrelação de primeira ordem e teste de Durbin-Watson. O uso de uma função difásica para predizer a produção de leite em programas de seleção é recomendado, sendo também possível estimar, com base nessa função, a produção de leite em 305 dias.

  13. American Brachytherapy Society recommendations for reporting morbidity after prostate brachytherapy

    International Nuclear Information System (INIS)

    Nag, Subir; Ellis, Rodney J.; Merrick, Gregory S.; Bahnson, Robert; Wallner, Kent; Stock, Richard

    2002-01-01

    Purpose: To standardize the reporting of brachytherapy-related prostate morbidity to guide ongoing clinical practice and future investigations. Methods: Members of the American Brachytherapy Society (ABS) with expertise in prostate brachytherapy performed a literature review and, guided by their clinical experience, formulated specific recommendations for reporting on morbidity related to prostate brachytherapy. Results: The ABS recommends using validated, patient-administered health-related quality-of-life instruments for the determination of baseline and follow-up data regarding bowel, urinary, and sexual function. Both actuarial and crude incidences should be reported, along with the temporal resolution of specific complications, and correlated with the doses to the normal tissues. The International Prostate Symptom Score is recommended to assess urinary morbidity, and any dysuria, gross hematuria, urinary retention, incontinence, or medication use should be quantified. Likewise, the ''Sexual Health Inventory for Men,'' which includes the specific erectile questions of the International Index of Erectile Function, is the preferred instrument for reporting sexual function, and the loss of sexual desire, incidence of hematospermia, painful orgasm (orgasmalgia), altered orgasm intensity, decreased ejaculatory volume, use of erectile aids, and use of hormones for androgen deprivation should be quantified. The ABS recommends adoption of the Radiation Therapy Oncology Group/European Organization for Research and Treatment of Cancer acute and late radiation morbidity scoring scheme for reporting rectal morbidity and noting the incidence of rectal steroid, laser, or antidiarrheal use. Conclusion: It is important to focus on health-related quality-of-life issues in the treatment of prostate cancer, because the control rates are very similar between appropriate treatment modalities. The ABS recommends using the International Prostate Symptom Score, International Index of

  14. Ajuste produtivo e medidas de flexibilização da legislação trabalhista Productive adjustment and flexibilization in the labor laws

    Directory of Open Access Journals (Sweden)

    Rosana Ribeiro

    2007-05-01

    Full Text Available A partir da década de 90, a introdução de inovações tecnológicas e organizacionais na indústria brasileira se intensificou significativamente. Um dos objetivos deste artigo é analisar os principais obstáculos à negociação de cláusulas referentes a essas inovações entre o sindicato dos trabalhadores da indústria de calçados, da indústria siderúrgica e da indústria têxtil e os respectivos empresários. Outro objetivo é investigar o grau de difusão das recentes medidas de flexibilização da legislação trabalhista e a estratégia desses sindicatos. Palavras-chave: Ajuste produtivo. Negociação coletiva. Flexibilização. Legislação trabalhista. During the 90’s, many new technologies and innovations in organizational structure were introduced to the Brazilian industry. One of the purposes of this article is to analyze the main obstacles to the negotiation of new labor laws in relation to theses changes between labor unions (footwear, metal and textile industry workers and the owners of the factories. The other purpose is to investigate the level of diffusion of the recent flexibilization measures of the labor legislation and the strategy of these unions. Keywords: Productive adjustment. Collective negotiation. Flexibilization. Labor laws.

  15. Representación de la Enfermedad, Afrontamiento y Ajuste en los Trastornos Alimentarios

    Directory of Open Access Journals (Sweden)

    Yolanda Quiles Marcos

    2009-01-01

    Full Text Available El objetivo de esta investigación es evaluar la representación de la enfermedad en pacientes con un trastorno alimentario (TA, así como su relación con el afrontamiento y el ajuste, utilizando como marco teórico el Modelo del Sentido Común de Leventhal. Método: Participaron 98 mujeres diagnosticadas de un TA. La media de edad fue 20.8 años (dt=5.61. Para evaluar la representación de la enfermedad se administró la adaptación española para los TA del Cuestionario de Percepción de la Enfermedad Revisado (IPQ-R. Resultados: Respecto a la identidad, los síntomas más señalados fueron la "pérdida de peso" (89.8% y las "alteraciones en la menstruación" (81.6%. Consideran que su enfermedad tiene una larga duración y serias consecuencias, así como que tienen control y siguiendo un tratamiento es posible su curación. El 21% de la varianza de las estrategias evitativas fue explicado por diferentes dimensiones de la representación de la enfermedad. Se confirman los efectos directos de la representación de la enfermedad sobre el ajuste, pero no los del afrontamiento. Conclusiones: Los resultados apoyan la necesidad de intervenir sobre las creencias que tienen estas pacientes sobre su enfermedad con el fin de mejorar su ajuste psicosocial.

  16. Physical aspects of endovascular brachytherapy

    International Nuclear Information System (INIS)

    Kirisits, C.

    2001-11-01

    Restenosis is severely limiting the outcome of vascular interventions. In several clinical trials endovascular brachytherapy has shown to reduce the restenosis rate. Local radiotherapy to the injured vessel wall is a promising new type of treatment in order to inhibit a complex wound healing process resulting in cell proliferation and re-obstruction of the treated vessel. Treatment planning has to be based on the dose distribution in the vicinity of the sources used. Source strength was determined in terms of air kerma rate for gamma nuclides (Iridium-192) and absorbed dose to water at reference distance of 2 mm for beta nuclides (Strontium-90/Yttrium-90, Phosphor-32), respectively. Radial dose profiles and the Reference Isodose Length (RIL) were determined using the EGSnrc code and GafChromic film. Good agreement was found between both methods. In order to treat the entire clinical target length, the (RIL) is an essential value during treatment planning. Examples are described for different levels of treatment planing including recommendations for optimal choice and positioning of the radioactive devices inside the artery. IVUS based treatment planning is illustrated with superposition of isodoses on cross-sectional images. A calculation model for radioactive stents is presented in order to determine dose volume histograms in a retrospective analysis. Radiation protection issues for endovascular brachytherapy are discussed in detail. Personal dose for the involved personnel is estimated based on calculations and measurements. Beta ray dosimetry is performed with suitable detectors. In order to estimate the exposure to the patient the dose to organs at risk is calculated and compared to the dose from angiography. There is an additional radiation exposure to patients and personnel caused by endovascular brachytherapy, but the values are much smaller than those caused by diagnostic angiography. (author)

  17. Performance profiling for brachytherapy applications

    Science.gov (United States)

    Choi, Wonqook; Cho, Kihyeon; Yeo, Insung

    2018-05-01

    In many physics applications, a significant amount of software (e.g. R, ROOT and Geant4) is developed on novel computing architectures, and much effort is expended to ensure the software is efficient in terms of central processing unit (CPU) time and memory usage. Profiling tools are used during the evaluation process to evaluate the efficiency; however, few such tools are able to accommodate low-energy physics regions. To address this limitation, we developed a low-energy physics profiling system in Geant4 to profile the CPU time and memory of software applications in brachytherapy applications. This paper describes and evaluates specific models that are applied to brachytherapy applications in Geant4, such as QGSP_BIC_LIV, QGSP_BIC_EMZ, and QGSP_BIC_EMY. The physics range in this tool allows it to be used to generate low energy profiles in brachytherapy applications. This was a limitation in previous studies, which caused us to develop a new profiling tool that supports profiling in the MeV range, in contrast to the TeV range that is supported by existing high-energy profiling tools. In order to easily compare the profiling results between low-energy and high-energy modes, we employed the same software architecture as that in the SimpliCarlo tool developed at the Fermilab National Accelerator Laboratory (FNAL) for the Large Hadron Collider (LHC). The results show that the newly developed profiling system for low-energy physics (less than MeV) complements the current profiling system used for high-energy physics (greater than TeV) applications.

  18. Ajuste del Índice de Pont para mujeres y hombres

    Directory of Open Access Journals (Sweden)

    Paula María Nava–Salcedo

    2014-07-01

    Full Text Available La forma de arco dental de mujeres y hombres es diferente, en los hombres es amplio y en mujeres de forma parabólica. En ortodoncia existen índices y métodos para la predicción del ancho y forma del arco ideal, uno de estos índices es el de Pont que no toma en cuenta las diferencias entre sexos. Objetivos: determinar la efectividad del índice de Pont al emplearlo en hombres y mujeres, realizar el ajuste si fuera necesario a las formulas del índice de Pont para poder aplicarlo en hombres y mujeres. Materiales y métodos: investigación descriptiva, no experimental y transversal. La muestra fue de 139 modelos de estudio, 94 de pacientes femeninos y 45 de pacientes masculinos, por lo que se seleccionaron 45 modelos de pacientes femeninos de forma aleatoria para igualar las muestras. Se compararon mediante una t de Student los valores reales de la muestra de hombres con los de las mujeres y el resultado del análisis de Pont en hombres y mujeres. Se realizó el ajuste de las constantes del índice de Pont para mujeres y  hombres, se aplicó a ambas poblaciones, el resultado se  comparó con los valores reales interpremolar e intermolar en maxilar y mandíbula. Resultados: el análisis de Pont no es efectivo para utilizarse en mujeres y hombres de Nayarit, se encontraron diferencias transversales entre ambas poblaciones, los ajustes realizados para la población femenina y masculinafue efectiva para utilizase en la población de Nayarit. Conclusiones: El índice de Pont no es aplicable debido a que sobreestima los valores de la población femenina y masculinade la población de Nayarit. Los ajustes realizados fueron efectivos y se recomienda evaluarlo en otras poblaciones.

  19. Ajuste de la fuerza de infección del dengue

    OpenAIRE

    Aldana-Bermúdez, Eliécer; Restrepo-Triviño, Maribel; Muñoz-Loaiza, Aníbal

    2017-01-01

    RESUMEN Objetivo Plantear un modelo matemático hospedero vector para el ajuste de la fuerza de infección del dengue en una población variable con crecimiento logístico y ciclo de vida del mosquito con tasa de ovoposición periódica, considerando inmunidad a un serotipo. Métodos El modelo matemático propuesto está representado por ocho ecuaciones diferenciales a las que se les calcula la fuerza de infección por el método de las redes libres de escala. Resultados Se presenta una simulación...

  20. Diferencias en el ajuste psicológico, familiar y escolar en adolescentes agresores de cyberbullying

    OpenAIRE

    Ortega-Barón, J.; Buelga, S.; Carrascosa, L.; Cava, M.J.

    2016-01-01

    INTRODUCCIÓN: El acoso a través de las TICs entre niños y adolescentes suscita gran preocupación en la comunidad científica. Sin embargo, en comparación con la amplia investigación realizada sobre las cibervíctimas, todavía no son muchos los estudios realizados sobre los ciberagresores. El objetivo principal del presente estudio fue analizar la existencia de diferencias entre ciberagresores (severos y ocasionales) y adolescentes no implicados en cyberbullying en los indicadores de ajuste psic...

  1. Guidelines for comprehensive quality assurance in brachytherapy

    International Nuclear Information System (INIS)

    Goldson, A.L.; Nibhanupudy, J.R.

    1984-01-01

    Brachytherapy treatment techniques can provide significant improvement in local control and overall survival, but only when quality assurance can be guaranteed. To establish brachytherapy quality assurance, basic requirements for three predetermined subdivisions of clinical institutions will be forwarded. These are: (1) centers having minimum requirements to provide brachytherapy, (2) intermediate centers such as regional or community hospitals, and (3) optimal centers such as university hospital and cancer centers. This presentation will highlight personnel needs, equipment requirements, academic activities, clinical experience with these systems and proposed quality assurance guidelines

  2. Experience with LDR and MDR brachytherapy for cervical cancer

    International Nuclear Information System (INIS)

    Okawa, Tomohiko; Okawa, Midori-Kita; Kaneyasu, Yuko; Karasawa, Kumiko; Fukuhara, Noboru

    1996-01-01

    As the brachytherapy dose-rate increases, it is necessary to reduce the total dose or to increase the fraction number with reducing the fraction dose in order not to increase the incidence of the late effect. With the introduction to the Tokyo Women's Medical College, Hospital of a remote afterloading system of Selectron - MDR, delivering dose-rate to point A became approximately twice of that with our classical cesium LDR manual afterloading technique. Material and Methods: Between 1987 to 1993 a total of, previously untreated 74 patients with cervical cancer received MDR brachytherapy using a Selection - MDR. This analysis is therefore of those patients series who underwent radical radioradiotherapy with MDR, 1987-1993, in comparison with the 347 cases who were treated with classical manual LDR afterloading machine, 1969-1986. The treatment was a brachytherapy during external radiotherapy and dos-rate at point A was 160-180 cGy/hour with MDR and 80-90 cGy/hour with LDR. The mean fraction dose was 800-1000 cGy by MDR and 1000-1200 cGy by LDR and fraction number was increased 1-2times in the MDR group with no change of a total dose at point A. Results: The mean age was 63.3 years in the MDR group and 60.2 in the LDR group. In the MDR group, 4 patients were at stage I, 16 stage II, 32 stage III, and 22 stage IV. In the LDR group, 32 were at stage I, 83 stage II, 183 stage III, and 49 stage IV. The medical rate was not significantly different between two groups. The tumor response by manual examination one month after radiotherapy showed no significant difference. The 5-year survival rate for the MDR and LDR groups were 100% : 78% at stage I, 61% : 71% at stage II and 52% : 53% at stage III, with no significant differences. Late complications by severity with grade II-III according to Kottureire's classification were not significantly different in the rectum or bladder. These results suggested that MDR brachytherapy was useful for the patients' QOL as it reduced the

  3. Sistema Computacional para Ajuste de Funções Densidade de Probabilidade

    Directory of Open Access Journals (Sweden)

    Daniel Henrique Breda Binoti

    Full Text Available RESUMO Este trabalho teve por objetivo iniciar, implementar e validar um projeto de construção de um sistema computadorizado para ajuste de funções densidade de probabilidade. O FitFD foi desenvolvido utilizando-se a linguagem de programação Java. Como ambiente de desenvolvimento foram utilizadas a IDE (Integrated Development Environment Netbeans 7.1 e a JDK 7.3 (Java Development Kit. Os testes do sistema foram realizados em ambiente Windows. Foram implementadas no sistema as seguintes funções densidade de probabilidade: Weibull (2P, 3P, 2P com dap mínimo como locação, 3P truncada, hiperbólica (2P, 3P, 2P com dap mínimo como locação, 3P truncada, log-logística (2P, 3P, 2P com dap mínimo como locação, logística generalizada, Fatigue life (2P e 3P e Frechet (2P e 3P. O sistema desenvolvido auxilia os usuários na definição e escolha da fdp que melhor atenda suas necessidades, contudo melhorias são necessárias. O projeto iniciado mostrou-se eficiente para ajustes de funções de densidade probabilidade.

  4. Capacidade máxima de adsorção de fósforo e constante de energia em Latossolo Bruno em razão de diferentes ajustes do modelo Langmuir

    Directory of Open Access Journals (Sweden)

    Clovisson Menotti Boeira de Oliveira

    2014-12-01

    Full Text Available A capacidade máxima de adsorção de fósforo (CMAP é um parâmetro bastante útil para caracterizar a capacidade de adsorção de fósforo (P do solo e, por isso, o modelo de Langmuir, que possibilita essa estimativa, é bastante difundido. Porém, se o ajuste da equação for realizado por modelos não lineares ou linearizados, ou se forem escolhidos modelos de região única ou múltiplas, nem sempre os valores estimados da CMAP e da constante de energia de ligação (k são semelhantes. O objetivo deste trabalho foi avaliar o efeito do uso de diferentes métodos de ajuste do modelo de Langmuir sobre os valores estimados de CMAP e k. Para isso, utilizouse um único solo de alta capacidade de adsorção de P, o qual foi misturado a quantidades crescentes de areia lavada, construindo-se sistemas com capacidades de sorção crescentes, mas com a fase sólida constituída da mesma mineralogia. Foi utilizado solo do horizonte B de um Latossolo Bruno com 800 g kg-1 de argila, o qual foi misturado com areia em quantidades para obterem-se solos artificiais com 0, 200, 400, 600 e 800 g kg-1 de argila. Esses solos artificiais foram incubados por 30 dias com calcário para elevar o pH(H2O até 6,0 e, após, foram secos em estufa e peneirados. Foram realizadas as isotermas de adsorção e os dados ajustados pelo modelo de Langmuir, usando os seguintes métodos: NLin - não linear com região única; L-1R - linearização com região única; L-2RG - linearização com duas regiões, ajuste gráfico; L-3RG - linearização com três regiões, ajuste gráfico; L-2RE linerização com duas regiões, ajuste estatístico. Os resultados evidenciaram que todos os métodos utilizados estimaram valores de CMAP proporcionais ao teor de argila dos solos e poderiam ser usados para caracterizar os solos. Contudo, quando utilizados ajustes com mais de uma região de adsorção, os valores da CMAP para a última região foram sensivelmente superiores

  5. Concomitant chemoradiotherapy with high dose rate brachytherapy ...

    African Journals Online (AJOL)

    Concomitant chemoradiotherapy with high dose rate brachytherapy as a definitive treatment modality for locally advanced cervical cancer. T Refaat, A Elsaid, N Lotfy, K Kiel, W Small Jr, P Nickers, E Lartigau ...

  6. Comprehensive brachytherapy physical and clinical aspects

    CERN Document Server

    Baltas, Dimos; Meigooni, Ali S; Hoskin, Peter J

    2013-01-01

    Modern brachytherapy is one of the most important oncological treatment modalities requiring an integrated approach that utilizes new technologies, advanced clinical imaging facilities, and a thorough understanding of the radiobiological effects on different tissues, the principles of physics, dosimetry techniques and protocols, and clinical expertise. A complete overview of the field, Comprehensive Brachytherapy: Physical and Clinical Aspects is a landmark publication, presenting a detailed account of the underlying physics, design, and implementation of the techniques, along with practical guidance for practitioners. Bridging the gap between research and application, this single source brings together the technological basis, radiation dosimetry, quality assurance, and fundamentals of brachytherapy. In addition, it presents discussion of the most recent clinical practice in brachytherapy including prostate, gynecology, breast, and other clinical treatment sites. Along with exploring new clinical protocols, ...

  7. Evolution of brachytherapy for prostate carcinoma

    International Nuclear Information System (INIS)

    Qin Lan

    2005-01-01

    Brachytherapy is one of the most main management to prostate carcinoma. This method has been rapidly accepted in clinical application since it is a convenient, little-traumatic, and outpatient therapy. With the development of techniques of production of radio-seeds, imaging modality and three-dimensional radiotherapy plan system, brachytherapy has been made a virtually progress in improving curative-effect and reducing damage to surrounding normal tissue. (authors)

  8. Long duration mild temperature hyperthermia and brachytherapy.

    Science.gov (United States)

    Armour, E P; Raaphorst, G P

    2004-03-01

    Combining long duration mild temperature hyperthermia (LDMH) and low dose-rate (LDR) brachytherapy to enhance therapeutic killing of cancer cells was proposed many years ago. The cellular and tumour research that supports this hypothesis is presented in this review. Research describing LDMH interaction with pulsed brachytherapy and high dose-rate brachytherapy using clinically relevant parameters are compared with LDMH/LDR brachytherapy. The mechanism by which LDMH sensitizes LDR has been established as the inhibition of sublethal damage repair. The molecular mechanisms have been shown to involve DNA repair enzymes, but the exact nature of these processes is still under investigation. The relative differences between LDMH interactions with human and rodent cells are presented to help in the understanding of possible roles of LDMH in clinical application. The role of LDMH in modifying tumour blood flow and its possible role in LDR sensitization of tumours is also presented. The positive aspects of LDMH-brachytherapy for clinical application are sixfold; (1) the thermal goals (temperature, time and volume) are achievable with currently available technology, (2) the hyperthermia by itself has no detectable toxic effects, (3) thermotolerance appears to play a minor if any role in radiation sensitization, (4) TER of around 2 can be expected, (5) hypoxic fraction may be decreased due to blood flow modification and (6) simultaneous chemotherapy may also be sensitized. Combined LDMH and brachytherapy is a cancer therapy that has established biological rationale and sufficient technical and clinical advancements to be appropriately applied. This modality is ripe for clinical testing.

  9. The American Brachytherapy Society recommendations for low-dose-rate brachytherapy for carcinoma of the cervix

    International Nuclear Information System (INIS)

    Nag, Subir; Chao, Clifford; Erickson, Beth; Fowler, Jeffery; Gupta, Nilendu; Martinez, Alvaro; Thomadsen, Bruce

    2002-01-01

    Purpose: This report presents guidelines for using low-dose-rate (LDR) brachytherapy in the management of patients with cervical cancer. Methods: Members of the American Brachytherapy Society (ABS) with expertise in LDR brachytherapy for cervical cancer performed a literature review, supplemented by their clinical experience, to formulate guidelines for LDR brachytherapy of cervical cancer. Results: The ABS strongly recommends that radiation treatment for cervical carcinoma (with or without chemotherapy) should include brachytherapy as a component. Precise applicator placement is essential for improved local control and reduced morbidity. The outcome of brachytherapy depends, in part, on the skill of the brachytherapist. Doses given by external beam radiotherapy and brachytherapy depend upon the initial volume of disease, the ability to displace the bladder and rectum, the degree of tumor regression during pelvic irradiation, and institutional practice. The ABS recognizes that intracavitary brachytherapy is the standard technique for brachytherapy for cervical carcinoma. Interstitial brachytherapy should be considered for patients with disease that cannot be optimally encompassed by intracavitary brachytherapy. The ABS recommends completion of treatment within 8 weeks, when possible. Prolonging total treatment duration can adversely affect local control and survival. Recommendations are made for definitive and postoperative therapy after hysterectomy. Although recognizing that many efficacious LDR dose schedules exist, the ABS presents suggested dose and fractionation schemes for combining external beam radiotherapy with LDR brachytherapy for each stage of disease. The dose prescription point (point A) is defined for intracavitary insertions. Dose rates of 0.50 to 0.65 Gy/h are suggested for intracavitary brachytherapy. Dose rates of 0.50 to 0.70 Gy/h to the periphery of the implant are suggested for interstitial implant. Use of differential source activity or

  10. Acute vasculitis after endovascular brachytherapy

    International Nuclear Information System (INIS)

    Fajardo L-G, Luis F.; Prionas, Stavros D.; Kaluza, Grzegorz L.; Raizner, Albert E.

    2002-01-01

    Purpose: Angioplasty effectively relieves coronary artery stenosis but is often followed by restenosis. Endovascular radiation (β or γ) at the time of angioplasty prevents restenosis in a large proportion of vessels in swine (short term) and humans (short and long term). Little information is available about the effects of this radiation exposure beyond the wall of the coronary arteries. Methods and Materials: Samples were obtained from 76 minipigs in the course of several experiments designed to evaluate endovascular brachytherapy: 76 of 114 coronary arteries and 6 of 12 iliac arteries were exposed to endovascular radiation from 32 P sources (35 Gy at 0.5 mm from the intima). Two-thirds of the vessels had angioplasty or stenting. The vessels were systematically examined either at 28 days or at 6 months after radiation. Results: We found an unexpected lesion: acute necrotizing vasculitis in arterioles located ≤2.05 mm from the target artery. It was characterized by fibrinoid necrosis of the wall, often associated with lymphocytic exudates or thrombosis. Based on the review of perpendicular sections of tissue samples, the arterioles had received between 6 and 40 Gy. This arteriolar vasculitis occurred at 28 days in samples from 51% of irradiated coronary arteries and 100% of irradiated iliac arteries. By 6 months, the incidence of acute vasculitis decreased to 24% around the coronary arteries. However, at that time, healing vasculitis was evident, often with luminal narrowing, in 46% of samples. Vasculitis was not seen in any of 44 samples from unirradiated vessels (0%) and had no relation to angioplasty, stenting, or their sequelae. This radiation-associated vasculitis in the swine resembles the localized lymphocytic vasculitis that we have reported in tissues of humans exposed to external radiation. On the other hand, it is quite different from the various types of systemic vasculitis that occur in nonirradiated humans. Conclusion: Endoarterial brachytherapy

  11. Navigation system for interstitial brachytherapy

    International Nuclear Information System (INIS)

    Strassmann, G.; Kolotas, C.; Heyd, R.

    2000-01-01

    The purpose of the stud was to develop a computed tomography (CT) based electromagnetic navigation system for interstitial brachytherapy. This is especially designed for situations when needles have to be positioned adjacent to or within critical anatomical structures. In such instances interactive 3D visualisation of the needle positions is essential. The material consisted of a Polhemus electromagnetic 3D digitizer, a Pentium 200 MHz laptop and a voice recognition for continuous speech. In addition, we developed an external reference system constructed of Perspex which could be positioned above the tumour region and attached to the patient using a non-invasive fixation method. A specially designed needle holder and patient bed were also developed. Measurements were made on a series of phantoms in order to study the efficacy and accuracy of the navigation system. The mean navigation accuracy of positioning the 20.0 cm length metallic needles within the phantoms was in the range 2.0-4.1 mm with a maximum of 5.4 mm. This is an improvement on the accuracy of a CT-guided technique which was in the range 6.1-11.3 mm with a maximum of 19.4 mm. The mean reconstruction accuracy of the implant geometry was 3.2 mm within a non-ferromagnetic environment. We found that although the needles were metallic this did not have a significant influence. We also found for our experimental setups that the CT table and operation table non-ferromagnetic parts had no significant influence on the navigation accuracy. This navigation system will be a very useful clinical tool for interstitial brachytherapy applications, particularly when critical structures have to be avoided. It also should provide a significant improvement on our existing technique

  12. Incorporação da densidade no ajuste de dois modelos à curva de retenção de água no solo

    Directory of Open Access Journals (Sweden)

    C. A. Tormena

    2002-06-01

    Full Text Available A curva de retenção de água no solo é fundamental para o desenvolvimento de estudos relacionados com a dinâmica da água, com a modelagem de processos físicos do solo e crescimento das plantas. Normalmente, a curva de retenção é obtida por meio de medidas simultâneas do conteúdo de água (θ e do potencial mátrico da água no solo (ψ numa única amostra. Um procedimento alternativo consiste em utilizar várias amostras por ψ para descrever a curva de retenção. A utilização deste procedimento requer a incorporação dos fatores de variação existentes entre as amostras nos parâmetros das funções matemáticas utilizadas para descrever essa curva. O objetivo deste trabalho foi obter a curva de retenção, utilizando esta última sistemática, e ajustar duas diferentes funções não-lineares aos dados de θ(ψ. Amostras indeformadas (0,05 m de diâmetro e 0,05 m de altura foram obtidas num Latossolo Vermelho distroférrico cultivado com milho sob plantio direto e preparo convencional do solo. Foram retiradas 96 amostras por sistema de preparo, na profundidade de 0-0,10 m, na linha e na entrelinha da cultura. A curva de retenção foi obtida utilizando-se 12 ψ, sendo 16 amostras por ψ: oito por sistema de preparo e quatro por posição amostrada. Os modelos de Genuchten (1980 - VG e o de Hutson & Cass (1987 - HC foram ajustados aos dados. Funções relacionando os parâmetros dos modelos com as variáveis independentes preparo, posição de amostragem e densidade do solo (Ds os substituíram no ajuste dos dados. Não houve influência estatisticamente significativa dos sistemas de preparo e posição de amostragem (p > 0,05 no ajuste das funções aos dados . Com a função de VG obtiveram-se efeitos significativos da Ds no parâmetro n, o qual foi descrito por uma função quadrática da Ds. Resultado similar foi obtido com o parâmetro "a" da função de HC. A curva de retenção foi sensível às variações da Ds e o

  13. 10 CFR 35.2406 - Records of brachytherapy source accountability.

    Science.gov (United States)

    2010-01-01

    ... 10 Energy 1 2010-01-01 2010-01-01 false Records of brachytherapy source accountability. 35.2406... Records of brachytherapy source accountability. (a) A licensee shall maintain a record of brachytherapy source accountability required by § 35.406 for 3 years. (b) For temporary implants, the record must...

  14. 10 CFR 35.406 - Brachytherapy sources accountability.

    Science.gov (United States)

    2010-01-01

    ... 10 Energy 1 2010-01-01 2010-01-01 false Brachytherapy sources accountability. 35.406 Section 35....406 Brachytherapy sources accountability. (a) A licensee shall maintain accountability at all times... area. (c) A licensee shall maintain a record of the brachytherapy source accountability in accordance...

  15. La inteligencia emocional y el ajuste psicológico: un estudio transcultural

    OpenAIRE

    Fulquez Castro, Sandra Carina

    2011-01-01

    La intel·ligència emocional (IE) és una competència de l'ésser humà. Així mateix, elements psicològics com l'autoestima, l-autoconfiança, les relacions amb els iguals i les relacions amb els pares -en el cas dels adolescents- constitueixen eines que guien la salut mental i l'adaptació social de l'individu. L'estudi que es presenta demostra l'associació existent entre la IE (atenció emocional -AE- claredat emocional -CE- i reparació emocional -RE) i les variables d'ajust psicològic, així com d...

  16. Uso de herramientas numéricas y computacionales en el ajuste de curvas

    OpenAIRE

    Ascheri, María; Pizarro, Rubén

    2006-01-01

    Nuestro objetivo es introducir a los alumnos de Cálculo Numérico en el uso de la técnica de ajuste de curvas por medio de la regresión con mínimos cuadrados en la solución de problemas de ingeniería, de física y de matemática aplicada, utilizando herramientas numéricas y computacionales. La metodología usada para apoyar el proceso de enseñanza-aprendizaje de este temática particular de Cálculo Numérico con computadora es la siguiente: se combina la enseñanza tradicional, las técnicas grupales...

  17. Cirurgia de estrabismo ajustável no peroperatório com anestesia tópica em pacientes com orbitopatia de Graves Intraoperative adjustable strabismus surgery under drop anesthesia in patients with Graves' orbitopathy

    Directory of Open Access Journals (Sweden)

    Patrícia Grativol Costa

    2008-06-01

    Full Text Available OBJETIVO: Descrever as características clínicas pré-operatórias dos pacientes com estrabismo secundário à orbitopatia de Graves e os resultados da cirurgia com anestesia tópica e sutura ajustável. MÉTODOS: Estudo retrospectivo realizado no Hospital das Clínicas da Universidade de São Paulo. Foram pesquisados os prontuários de todos os pacientes atendidos no ambulatório de estrabismo no período de março de 1994 a maio de 2004. Destes, foram separados aqueles com estrabismo associado à orbitopatia de Graves submetidos à cirurgia ajustável com anestesia tópica. As características clínicas pré-operatórias e os resultados cirúrgicos foram levantados a partir desta análise. RESULTADOS: Foram incluídos 13 pacientes. O tipo de desvio mais freqüentemente encontrado foi esotropia com hipotropia. Em 9 pacientes modificou-se o retrocesso programado no pré-operatório. Três casos necessitaram de uma segunda cirurgia. Após 6 meses de seguimento, 8 dos 13 pacientes estavam ortotrópicos ou com foria pequena e com algum grau de estereopsia. CONCLUSÃO: Neste estudo observou-se que 62% (8/13 dos pacientes apresentavam hipotropia com esotropia, provavelmente por causa do comprometimento associado do reto inferior e reto medial. Nove dos 13 pacientes necessitaram de ajuste no peroperatório e apenas 3 foram reoperados, indicando a importância da técnica ajustável para melhor alinhamento ocular no pós-operatório, possibilitando obter resultados mais satisfatórios.PURPOSE: To report the clinical features of strabismus associated with Graves' orbitopathy, and the results of surgery with adjustable suture under drop anesthesia. METHODS: The charts of 13 patients who had surgical treatment for strabismus related to Graves' orbitopathy at Hospital das Clínicas of University of São Paulo were retrospectively reviewed. Ocular motility, sensorial examination and the follow-up after strabismus correction were studied. RESULTS

  18. El papel de la concertación social ante la política de ajuste

    Directory of Open Access Journals (Sweden)

    Juan Raso Delgue

    2015-10-01

    Full Text Available Contenido: Introducción. Ajuste. Modos de producción y concertación. Nuevos actores y nuevas dimensiones del conflictos. Las dimensiones de la nueva concertación. Contenidos de la nueva concertación. Conclusiones

  19. Calculation of integrated biological response in brachytherapy

    International Nuclear Information System (INIS)

    Dale, Roger G.; Coles, Ian P.; Deehan, Charles; O'Donoghue, Joseph A.

    1997-01-01

    Purpose: To present analytical methods for calculating or estimating the integrated biological response in brachytherapy applications, and which allow for the presence of dose gradients. Methods and Materials: The approach uses linear-quadratic (LQ) formulations to identify an equivalent biologically effective dose (BED eq ) which, if applied to a specified tissue volume, would produce the same biological effect as that achieved by a given brachytherapy application. For simple geometrical cases, BED multiplying factors have been derived which allow the equivalent BED for tumors to be estimated from a single BED value calculated at a dose reference point. For more complex brachytherapy applications a voxel-by-voxel determination of the equivalent BED will be more accurate. Equations are derived which when incorporated into brachytherapy software would facilitate such a process. Results: At both high and low dose rates, the BEDs calculated at the dose reference point are shown to be lower than the true values by an amount which depends primarily on the magnitude of the prescribed dose; the BED multiplying factors are higher for smaller prescribed doses. The multiplying factors are less dependent on the assumed radiobiological parameters. In most clinical applications involving multiple sources, particularly those in multiplanar arrays, the multiplying factors are likely to be smaller than those derived here for single sources. The overall suggestion is that the radiobiological consequences of dose gradients in well-designed brachytherapy treatments, although important, may be less significant than is sometimes supposed. The modeling exercise also demonstrates that the integrated biological effect associated with fractionated high-dose-rate (FHDR) brachytherapy will usually be different from that for an 'equivalent' continuous low-dose-rate (CLDR) regime. For practical FHDR regimes involving relatively small numbers of fractions, the integrated biological effect to

  20. A tecnologia da informação como suporte ao ajuste da previsão da demanda: um estudo de caso em uma empresa de bebidas carbonatadas

    Directory of Open Access Journals (Sweden)

    Alexandre Pereira Salgado Junior

    2010-08-01

    Full Text Available A gestão da cadeia de suprimentos é um problema que sempre instigou gestores por todo o mundo, ademais os modelos de previsão da demanda tradicionais não mais satisfazem os novos desafios da gestão dos estoques e da ruptura. Assim, novas soluções foram desenvolvidas, buscando-se melhorar os níveis de serviço prestados ao consumidor final. Dentre elas, destaca-se a utilização da TI que, por disponibilizar a informação em tempo real, pode contribuir para o ajuste dos modelos tradicionais de previsão da demanda. Desta forma, o objetivo desta pesquisa é analisar como a TI pode ajudar o segmento de bebidas a ajustar sua previsão de demanda. O método de pesquisa utilizado foi o estudo de caso, analisando uma empresa de bebidas carbonatadas, escolhida por conveniência. Para análise dos dados, utilizou-se a técnica de análise de conteúdo. Como principais resultados destacam-se melhorias no nível dos estoques, na ruptura e no nível de serviço.

  1. ACPSEM brachytherapy working group recommendations for quality assurance in brachytherapy

    International Nuclear Information System (INIS)

    Dempsey, Claire; Smith, Ryan; Nyathi, Thulani; Ceylan, Abdurrahman; Howard, Lisa; Patel, Virendra; Dam, Ras; Haworth, Annette

    2013-01-01

    The Australasian College of Physical Scientists and Engineers in Medicine (ACPSEM) Radiation Oncology Specialty Group (ROSG) formed a series of working groups in 2011 to develop recommendation papers for guidance of radiation oncology medical physics practice within the Australasian setting. These recommendations are intended to provide guidance for safe work practices and a suitable level of quality control without detailed work instructions. It is the responsibility of the medical physicist to ensure that locally available equipment and procedures are sufficiently sensitive to establish compliance to these recommendations. The recommendations are endorsed by the ROSG, have been subject to independent expert reviews and have also been approved by the ACPSEM Council. For the Australian audience, these recommendations should be read in conjunction with the Tripartite Radiation Oncology Practice Standards. This publication presents the recommendations of the ACPSEM Brachytherapy Working Group (BTWG) and has been developed in alignment with other international associations. However, these recommendations should be read in conjunction with relevant national, state or territory legislation and local requirements, which take precedence over the ACPSEM recommendation papers. It is hoped that the users of this and other ACPSEM recommendation papers will contribute to the development of future versions through the Radiation Oncology Specialty Group of the ACPSEM.

  2. Local anesthesia for prostate brachytherapy

    International Nuclear Information System (INIS)

    Wallner, Kent; Simpson, Colleen; Roof, James; Arthurs, Sandy; Korssjoen, Tammy; Sutlief, Steven

    1999-01-01

    Purpose: To demonstrate the technique and feasibility of prostate brachytherapy performed with local anesthesia only. Methods and Materials: A 5 by 5 cm patch of perineal skin and subcutaneous tissue is anesthetized by local infiltration of 10 cc of 1% lidocaine with epinephrine, using a 25-gauge 5/8-inch needle. Immediately following injection into the subcutaneous tissues, the deeper tissues, including the pelvic floor and prostate apex, are anesthetized by injecting 15 cc lidocaine solution with approximately 8 passes of a 20-gauge 1.0-inch needle. Following subcutaneous and peri-apical lidocaine injections, the patient is brought to the simulator suite and placed in leg stirrups. The transrectal ultrasound (TRUS) probe is positioned to reproduce the planning images and a 3.5- or 6.0-inch, 22-gauge spinal needle is inserted into the peripheral planned needle tracks, monitored by TRUS. When the tips of the needles reach the prostatic base, about 1 cc of lidocaine solution is injected in the intraprostatic track, as the needle is slowly withdrawn, for a total volume of 15 cc. The implants are done with a Mick Applicator, inserting and loading groups of two to four needles, so that a maximum of only about four needles are in the patient at any one time. During the implant procedure, an additional 1 cc of lidocaine solution is injected into one or more needle tracks if the patient experiences substantial discomfort. The total dose of lidocaine is generally limited to 500 mg (50 ml of 1% solution). Results: To date, we have implanted approximately 50 patients in our simulator suite, using local anesthesia. Patients' heart rate and diastolic blood pressure usually showed moderate changes, consistent with some discomfort. The time from first subcutaneous injection and completion of the source insertion ranged from 35 to 90 minutes. Serum lidocaine levels were below or at the low range of therapeutic. There has been only one instance of acute urinary retention in the

  3. Relación entre variables familiares y el ajuste conyugal

    Directory of Open Access Journals (Sweden)

    Nerea Jiménez-Picón

    2018-04-01

    Full Text Available Resumen: Objetivo: Analizar si las variables familiares tales como tipo de relación de pareja, años de matrimonio, existencia de hijos, número de miembros de la unidad familiar, etapas del ciclo vital familiar, transición entre etapas, apoyo social percibido y/o acontecimientos vitales estresantes se relacionan con el ajuste conyugal. Diseño: Estudio transversal y correlacional mediante encuestas. Emplazamiento: Consultas de atención primaria y unidades de hospitalización de los centros seleccionados de la provincia de Sevilla, España. Participantes: Muestra consecutiva estratificada por cuotas de 369 parejas, mayores de 18 años, heterosexuales, que mantenían una relación de pareja, con o sin hijos, residentes en Sevilla. Mediciones principales: Se emplea cuestionario autoadministrado con las variables sociodemográficas y las escalas Versión Breve de la Escala de Ajuste Diádico, Cuestionario de MOS de Apoyo Social Percibido y Escala de Reajuste Social. Se realizó análisis descriptivo e inferencial con estadísticos de correlación y regresión multivariante. Resultados: Relaciones estadísticamente significativas entre el ajuste conyugal y los años de matrimonio (r = −0,10; p < 0,05, la etapa del ciclo vital familiar (F = 2,65; p < 0,05, la transición entre etapas (rpb = 0,11; p < 0,05 y el apoyo social percibido (r = 0,44; p < 0,001. El modelo de regresión mostró la capacidad predictiva del apoyo social percibido y etapa del ciclo vital familiar (etapa madura-anciana sobre el ajuste conyugal (R2 = 0,21; F = 9,9; DF = 356; p < 0,001. Conclusiones: Desde atención primaria, se puede valorar a las parejas, ofrecer recursos y proporcionar apoyo. También pueden identificarse variables que ayuden a mejorar la relación conyugal. Abstract: Objective: To determine whether family variables, such as type of relationship, years of marriage, existence of offspring, number of members of family, stage of family

  4. Proficiency-based cervical cancer brachytherapy training.

    Science.gov (United States)

    Zhao, Sherry; Francis, Louise; Todor, Dorin; Fields, Emma C

    2018-04-25

    Although brachytherapy increases the local control rate for cervical cancer, there has been a progressive decline in its use. Furthermore, the training among residency programs for gynecologic brachytherapy varies considerably, with some residents receiving little to no training. This trend is especially concerning given the association between poor applicator placement and decline in local control. Considering the success of proficiency-based training in other procedural specialties, we developed and implemented a proficiency-based cervical brachytherapy training curriculum for our residents. Each resident placed tandem and ovoid applicators with attending guidance and again alone 2 weeks later using a pelvic model that was modified to allow for cervical brachytherapy. Plain films were taken of the pelvic model, and applicator placement quality was evaluated. Other evaluated metrics included retention of key procedural details, the time taken for each procedure and presession and postsession surveys to assess confidence. During the initial session, residents on average met 4.5 of 5 placement criteria, which improved to 5 the second session. On average, residents were able to remember 7.6 of the 8 key procedural steps. Execution time decreased by an average of 10.5%. Resident confidence with the procedure improved dramatically, from 2.6 to 4.6 of 5. Residents who had previously never performed a tandem and ovoid procedure showed greater improvements in these criteria than those who had. All residents strongly agreed that the training was helpful and wanted to participate again the following year. Residents participating in this simulation training had measurable improvements in the time to perform the procedure, applicator placement quality, and confidence. This curriculum is easy to implement and is of great value for training residents, and would be particularly beneficial in programs with low volume of cervical brachytherapy cases. Simulation programs could

  5. 137Cs - Brachytherapy sources : a technology scenario

    International Nuclear Information System (INIS)

    Varma, R.N.

    2001-01-01

    Cancer has emerged as one of the major cause of morbidity and mortality all over the world. India houses world's second largest population and registers 4-5 lakhs new cancer cases every year. Cancer of cervix is most common form of malignancy among Indian women. Radiation therapy, especially intracavity brachytherapy in conjunction with other modalities like surgery, chemotherapy has been found to be highly effective for the management and control of cervical carcinoma at all stages. A technology has been developed indigenously for the fabrication of 137 Cs sources for brachytherapy applications

  6. American brachytherapy society (ABS) consensus guidelines for brachytherapy of esophageal cancer

    International Nuclear Information System (INIS)

    Gaspar, Laurie E.; Nag, Subir; Herskovic, Arnold; Mantravadi, Rao; Speiser, Burton

    1997-01-01

    Introduction: There is wide variation in the indications, treatment regimens, and dosimetry for brachytherapy in the treatment of cancer of the esophagus. No guidelines for optimal therapy currently exist. Methods and Materials: Utilizing published reports and clinical experience, representatives of the Clinical Research Committee of the American Brachytherapy Society (ABS) formulated guidelines for brachytherapy in esophageal cancer. Results: Recommendations were made for brachytherapy in the definitive and palliative treatment of esophageal cancer. (A) Definitive treatment: Good candidates for brachytherapy include patients with unifocal thoracic adeno- or squamous cancers ≤ 10 cm in length, with no evidence of intra-abdominal or metastatic disease. Contraindications include tracheal or bronchial involvement, cervical esophagus location, or stenosis that cannot be bypassed. The esophageal brachytherapy applicator should have an external diameter of 6-10 mm. If 5FU-based chemotherapy and 45-50-Gy external beam are used, recommended brachytherapy is either: (i) HDR 10 Gy in two weekly fractions of 5 Gy each; or (ii) LDR 20 Gy in a single course at 0.4-1 Gy/hr. All doses are specified 1 cm from the midsource or middwell position. Brachytherapy should follow external beam radiation therapy and should not be given concurrently with chemotherapy. (B) Palliative treatment: Patients with adeno- or squamous cancers of the thoracic esophagus with distant metastases or unresectable local disease progression/recurrence after definitive radiation treatment should be considered for brachytherapy with palliative intent. After limited dose (30 Gy) EBRT, the recommended brachytherapy is either: (i) HDR 10-14 Gy in one or two fractions; or (ii) LDR 20-25 Gy in a single course at 0.4-1 Gy/hr. The need for external beam radiation in newly diagnosed patients with a life expectancy of less than 3 months is controversial. In these cases, HDR of 15-20 Gy in two to four fractions or

  7. Comparación entre varias poblaciones estándar para el ajuste por edades

    Directory of Open Access Journals (Sweden)

    Javier Llorca Díaz

    2000-01-01

    Full Text Available FUNDAMENTO: Analizar el efecto que tiene la elección de una población de referencia sobre diferentes indicadores derivados de las tasas de mortalidad ajustadas por edad. MÉTODOS: Las tasas de mortalidad por diferentes causas de muerte en España de 1971 a 1992 son ajustadas empleando cuatro poblaciones de referencia: poblaciones españolas de 1971 y 1992, población estándar europea y población estándar mundial. Los resultados obtenidos con las cuatro poblaciones se comparan empleando tres indicadores: diferencia entre las tasas de 1992 y 1971, razón entre las tasas de 1992 y 1971y cambio anual porcentual entre 1971 y 1992. RESULTADOS: En la mayor parte de las causas de muerte estudiadas incluyendo el total de causas, la cardiopatía isquémica y casi todos los tumores, la razón de tasas y el porcentaje de cambio anual son similares con independencia de cuál sea la población estándar empleada. En cambio, la diferencia de tasas es muy diferente en función de la población de referencia. En las enfermedades infecciosas y el cáncer de testículo se produce la situación contraria: la diferencia de tasas es robusta mientras que la razón de tasas varía con la población estándar. Finalmente, la mortalidad por neumonía, enfermedad de Parkinson y cáncer de encéfalo muestra cambios en los tres indicadores utilizados. CONCLUSIONES: Es necesario realizar un análisis de las tasas específicas por edad antes de proceder a su ajuste. Este análisis permite averiguar si el ajuste por edades es correcto y qué indicador (diferencia, razón o cambio porcentual será adecuado para realizar comparaciones.

  8. Ajuste de parâmetros de transporte de solutos no solo utilizando Matlab 6.5 Adjustment of soil solute transport parameters with Matlab 6.5

    Directory of Open Access Journals (Sweden)

    Anderson L. de Souza

    2011-12-01

    Full Text Available O sucesso na utilização de modelos matemáticos no estudo do transporte de íons no solo está intimamente ligado à precisão com que os parâmetros de transporte envolvidos neste processo são estabelecidos. De maneira geral, tais parâmetros são determinados mediante a resolução de um problema de otimização não linear em que os dados experimentais, obtidos em ensaios de deslocamento miscível, são ajustados a um modelo teórico. Neste sentido, a utilização de softwares de alta performance no ajuste destes parâmetros mostra-se vantajosa, uma vez que, além da consistência e da disponibilidade de ferramentas numéricas preexistentes, possibilita a incorporação de novas rotinas de acordo com o fenômeno que se queira simular. Sendo assim, este trabalho teve como objetivo desenvolver, em ambiente MATLAB 6.5, uma rotina computacional para a otimização dos seguintes parâmetros de transporte: fator de retardamento (R e coeficiente de dispersão (D. A rotina desenvolvida foi aplicada a dados experimentais de três ensaios de deslocamento miscível do íon potássio em colunas preenchidas com um Latossolo Vermelho- -Amarelo, fase arenosa. A qualidade dos ajustes obtidos foi avaliada utilizando-se do coeficiente de exatidão. Concluiu-se que a rotina proposta apresentou ótimo desempenho, o que, além de reforçar a consistência do método numérico utilizado, indica que a rotina proposta neste trabalho pode contribuir com o avanço dos estudos teóricos da dinâmica da água e de solutos em meios porosos não saturados.The successful use of mathematical models in studies of solute transport in soil is dependent on the accuracy to which the transport parameters involved in this process can be specified. In general, these parameters are determined by using nonlinear optimization techniques to fit theoretical models to experimental data obtained in miscible displacement experiments. The use, therefore, of high-performance software to

  9. Elementos para el análisis de los programas de ajuste

    Directory of Open Access Journals (Sweden)

    Villamizar Helena

    1991-12-01

    Full Text Available

    La aplicación de las políticas generales, preconizadas por los programas de ajuste en América Latina, en la mayoría de los casos no dieron los resultados deseados. Su éxito necesariamente requería del cumplimiento de ciertos supuestos y condiciones que permitieran que las políticas de "gestión de demanda no generaran efectos negativos sobre el crecimiento en el largo plazo. Al no cumplirse algunos de 105 supuestos teóricos básicos, y al no contar los países con flujos de capitales adecuados y con un entorno externo abierto, la aplicación de estos programas se tradujo en grandes sacrificios en el crecimiento y muchas veces en la perpetuación de situaciones recesivas. Puesto que la región aun no ha encontrado una verdadera vía de solución, se hace imperioso abordar la construcción de una nueva perspectiva teórica, basada en supuestos realistas, que permita abordar los apremiantes problemas del desarrollo latinoamericano.

  10. La influencia de las diferencias entre el padre y la madre sobre el ajuste adolescente

    Directory of Open Access Journals (Sweden)

    Antonia Jiménez-Iglesias

    2015-01-01

    Full Text Available Este trabajo se centra en analizar cómo influyen en el consumo de sustancias (tabaco, alcohol y cannabis y el bienestar psicológico adolescente (calidad de vida relacionada con la salud y satisfacción vital las diferencias entre el padre y la madre en afecto, promoción de la autonomía, revelación, interés y conocimiento. La muestra estuvo compuesta por 10170 chicos y chicas españoles de 13 a 18 años de familias biparentales que participaron en la edición 2006 del estudio Health Behaviour in School-aged Children (HBSC. Los resultados mostraron que los adolescentes que indicaron que su padre y madre coincidían en presentar altos niveles en las dimensiones familiares analizadas consumieron menos sustancias y tuvieron mejor bienestar psicológico. Por el contrario, el ajuste de los adolescentes cuyos progenitores (padre y madre tenían bajos niveles en esas dimensiones familiares fue peor. Concretamente, la dimensión más importante para el consumo de sustancias fue el conocimiento parental y para el bienestar psicológico lo fue el afecto parental; la revelación adolescente solo fue relevante para el consumo de alcohol y la calidad de vida, mientras que la promoción parental de la autonomía lo fue para la calidad de vida.

  11. Lucha popular, democracia, neoliberalismo: protesta popular en América Latina en los años del ajuste

    Directory of Open Access Journals (Sweden)

    Martha Cecilia García V.

    2000-01-01

    Full Text Available Margarita López Maya (editora. Lucha popular, democracia, neoliberalismo: protesta popular en América Latina en los años del ajuste. Caracas: Nueva Sociedad, 1999, 264 páginas. Este libro presenta una compilación de diez artículos elaborados por investigadores de Argentina, México, Colombia, Guatemala, Brasil, República Dominicana y Venezuela, producto de sus investigaciones sobre luchas y movimientos sociales en estos países. La intención del libro, según la compiladora, es tratar de llegar de manera conjunta a algunas hipótesis sobre los procesos de protesta y sus relaciones con el neoliberalismo y descubrir el modo en que los sectores más golpeados en sus expectativas y condiciones de vida por las políticas de ajuste han comenzado a demandar sus derechos.

  12. Dose calculation in brachytherapy with microcomputers

    International Nuclear Information System (INIS)

    Elbern, A.W.

    1989-01-01

    The computer algorithms, that allow the calculation of brachytherapy doses and its graphic representation for implants, using programs developed for Pc microcomputers are presented. These algorithms allow to localized the sources in space, from their projection in radiographics images and trace isodose counter. (C.G.C.) [pt

  13. Severe rectal complications after prostate brachytherapy

    International Nuclear Information System (INIS)

    Wallner, Kent; Sutlief, Stephen; Bergsagel, Carl; Merrick, Gregory S.

    2015-01-01

    Purpose: Some investigators have reported severe rectal complications after brachytherapy. Due to the low number of such events, their relationship to dosimetric parameters has not been well characterized. Methods and materials: A total of 3126 patients were treated with low dose rate brachytherapy from 1998 through 2010. 2464 had implant alone, and 313 had implant preceded by 44–46 Gy supplemental external beam radiation (EBRT). Post-implant dosimetry was based on a CT scan obtained on the day of implant, generally within 30 min of the procedure. Every patient’s record was reviewed for occurrence of rectal complications. Results: Eight of 2464 patients (0.32%) treated with brachytherapy alone developed a radiation-related rectal fistula. Average prostatic and rectal dose parameters were moderately higher for fistula patients than for patients without a severe rectal complication. For instance, the average R100 was 1.2 ± 0.75 cc for fistula patients, versus 0.37 ± 0.88 cc for non-fistula patients. However, the fistula patients’ values were well within the range of values for patients without a rectal complication. Four patients had some attempt at repair or reconstruction, but long-term functional outcomes were not favorable. Conclusions: Rectal fistulas are a very uncommon potential complication of prostate brachytherapy, which can occur even in the setting of acceptable day 0 rectal doses. Their occurrence is not easily explained by standard dosimetric or clinical factors

  14. Endorectal high dose rate brachytherapy quality assurance

    International Nuclear Information System (INIS)

    Devic, S.; Vuong, T.; Evans, M.; Podgorsak, E.

    2008-01-01

    We describe our quality assurance method for preoperative high dose rate (HDR) brachytherapy of endorectal tumours. Reproduction of the treatment planning dose distribution on a daily basis is crucial for treatment success. Due to the cylindrical symmetry, two types of adjustments are necessary: applicator rotation and dose distribution shift along the applicator axis. (author)

  15. The hazy dawn of brachytherapy

    International Nuclear Information System (INIS)

    Dutreix, J.; Tubiana, M.; Pierquin, B.

    1998-01-01

    The discovery of radium by Pierre and Marie Curie in December 1898 opened a new era in science and within a few years provided medicine with a new means of tumor treatment. Their personal contribution to the start and early development of clinical applications should not be overlooked. The Curies did not limit their support to providing radium sources to medical pioneers but took a deep interest in the horizons of radiumtherapy. Pierre was one of the first to search for and demonstrate a biological effect of radium radiation. He investigated the radioactivity of the waters of hydrotherapeutic resorts. Marie took care of the measurement of the medical sources personally, convinced that the result of the treatment depends on the precise knowledge of the amount of radium applied. Her perseverance resulted in the establishment of the Institut du Radium (1909) in which, besides the physico-chemical laboratory, a biological department was set up. The latter became the Fondation Curie (1920), a leading medical center of treatment and training, with an integrated team of physicists, radiobiologists and clinicians led by Regaud. One hundred years after the discovery of radium, patients benefit today from the extensive clinical experience that has been collected over the years and from sophisticated developments in application techniques, dosimetry and quality assurance; the professional risk has been precisely assessed and the improvements in material and procedure have enabled the medical personnel to work in hazard-free conditions. This outcome results from the continuous progress that the pioneers gave impulse to. This paper intends to recall their efforts and achievements, as well as the difficulties and the problems they encountered during the first 2 decades when the sturdy foundations of brachytherapy were built. (Copyright (c) 1998 Elsevier Science B.V., Amsterdam. All rights reserved.)

  16. Dosimetric model for intravascular brachytherapy

    International Nuclear Information System (INIS)

    Flower, E.E.; Stroud, D.B.

    2000-01-01

    Full text: Intravascular brachytherapy has been shown to be a prophylaxis for restenosis. Adventitial macrophages, which are extremely radiosensitive, initiate neointima formation. A model of the dose levels of the treatment range is developed, assuming that the adventitia is the target tissue. If the adventitia receives a dose of less than 10 Gy, it is assumed the treatment will be ineffective. If the dose to any part of the wall is above 30 Gy, it is assumed that the treatment could be detrimental. Hence the treatment range is between 10 and 30 Gy, with 20 Gy being the optimum dosage to the adventitia. An algorithm using numerical integration of published dose kernels calculates the dose at any point surrounding a beta ( 32 P) line source of finite length. Dose profiles were obtained to demonstrate edge effects. For long lesions, the source is often stepped along the artery. Dose changes due to separation or overlapping of sources during source stepping procedures were also determined. Isodose curves were superimposed on intravascular ultrasound images to demonstrate dose levels. For an exposure time of 60 seconds with a 200mCi source, the optimum dose of 20 Gy occurs at a distance 1.94mm from the centre of the source. The upper limit of the treatment dose range (30 Gy) occurs at 1.59mm. The lower limit of the treatment dose range (10 Gy) occurs at 2.7mm. Significant perturbations to the treatment dose range can be caused by non-centering of the source, edge effects and separation or overlapping of sources in stepping procedures. Despite these concerns, many successful procedures have been reported and this implies that the model is over simplified and requires modifications. Copyright (2000) Australasian College of Physical Scientists and Engineers in Medicine

  17. Inteligência emocional percebida (IEP ajuste emocional e actividade física na terceira idade

    Directory of Open Access Journals (Sweden)

    Maria Manuela Lima de Figueiredo Queirós

    2007-06-01

    Full Text Available O interesse deste estudo está centrado na forma como interage a inteligência emocional percebida (IEP com a prática da actividade física e que peso específi co tem cada uma das variáveis estudadas sobre o ajuste emocional das pessoas nesta faixa etária e, consequentemente, na sua qualidade de vida.

  18. Prostate brachytherapy in Ghana: our initial experience

    Directory of Open Access Journals (Sweden)

    James Edward Mensah

    2016-10-01

    Full Text Available Purpose: This study presents the experience of a brachytherapy team in Ghana with a focus on technology transfer and outcome. The team was initially proctored by experienced physicians from Europe and South Africa. Material and methods : A total of 90 consecutive patients underwent either brachytherapy alone or brachytherapy in combination with external beam radiotherapy for prostate carcinoma between July 2008 and February 2014 at Korle Bu Teaching Hospital, Accra, Ghana. Patients were classified as low-risk, intermediate, and high-risk according to the National Comprehensive Cancer Network (NCCN criteria. All low-risk and some intermediate risk group patients were treated with seed implantation alone. Some intermediate and all high-risk group patients received brachytherapy combined with external beam radiotherapy. Results: The median patient age was 64.0 years (range 46-78 years. The median follow-up was 58 months (range 18-74 months. Twelve patients experienced biochemical failure including one patient who had evidence of metastatic disease and died of prostate cancer. Freedom from biochemical failure rates for low, intermediate, and high-risk cases were 95.4%, 90.9%, and 70.8%, respectively. Clinical parameters predictive of biochemical outcome included: clinical stage, Gleason score, and risk group. Pre-treatment prostate specific antigen (PSA was not a statistically significant predictor of biochemical failure. Sixty-nine patients (76.6% experienced grade 1 urinary symptoms in the form of frequency, urgency, and poor stream. These symptoms were mostly self-limiting. Four patients needed catheterization for urinary retention (grade 2. One patient developed a recto urethral fistula (grade 3 following banding for hemorrhoids. Conclusions : Our results compare favorably with those reported by other institutions with more extensive experience. We believe therefore that, interstitial permanent brachytherapy can be safely and effectively

  19. Automated intraoperative calibration for prostate cancer brachytherapy

    International Nuclear Information System (INIS)

    Kuiran Chen, Thomas; Heffter, Tamas; Lasso, Andras; Pinter, Csaba; Abolmaesumi, Purang; Burdette, E. Clif; Fichtinger, Gabor

    2011-01-01

    Purpose: Prostate cancer brachytherapy relies on an accurate spatial registration between the implant needles and the TRUS image, called ''calibration''. The authors propose a new device and a fast, automatic method to calibrate the brachytherapy system in the operating room, with instant error feedback. Methods: A device was CAD-designed and precision-engineered, which mechanically couples a calibration phantom with an exact replica of the standard brachytherapy template. From real-time TRUS images acquired from the calibration device and processed by the calibration system, the coordinate transformation between the brachytherapy template and the TRUS images was computed automatically. The system instantly generated a report of the target reconstruction accuracy based on the current calibration outcome. Results: Four types of validation tests were conducted. First, 50 independent, real-time calibration trials yielded an average of 0.57 ± 0.13 mm line reconstruction error (LRE) relative to ground truth. Second, the averaged LRE was 0.37 ± 0.25 mm relative to ground truth in tests with six different commercial TRUS scanners operating at similar imaging settings. Furthermore, testing with five different commercial stepper systems yielded an average of 0.29 ± 0.16 mm LRE relative to ground truth. Finally, the system achieved an average of 0.56 ± 0.27 mm target registration error (TRE) relative to ground truth in needle insertion tests through the template in a water tank. Conclusions: The proposed automatic, intraoperative calibration system for prostate cancer brachytherapy has achieved high accuracy, precision, and robustness.

  20. El ajuste estructural neoliberal en el sector agrario latinoamericano en la era de la globalización

    Directory of Open Access Journals (Sweden)

    Francisco García Pascual

    2003-10-01

    productividad,  balanza comercial, precios implícitos en la producción y en la exportación o nivel de ingresos de  los agricultores – podemos comprobar fehacientemente que la brecha que ha separado históricamente a la agricultura latinoamericana de  los sectores agrarios de los Estados Unidos o de la  Unión Europea es cada vez mayor. Es más, los  grandes problemas que atenazaban al mundo  agrario en América Latina a principios de los  ochenta (baja productividad, distribución desigual  de los recursos productivos, exclusión social, desequilibrios territoriales, amén de la dependencia tecnológica y de la dependencia financiera del  sector siguen siendo la realidad mayoritaria  después de dos décadas de ajuste estructural.

  1. Image Guided Cervical Brachytherapy: 2014 Survey of the American Brachytherapy Society

    Energy Technology Data Exchange (ETDEWEB)

    Grover, Surbhi, E-mail: Surbhi.grover@uphs.upenn.edu [Department of Radiation Oncology, Perelman School of Medicine, University of Pennsylvania, Philadelphia, Pennsylvania (United States); Harkenrider, Matthew M. [Department of Radiation Oncology, Stritch School of Medicine, Loyola University Chicago, Chicago, Illinois (United States); Cho, Linda P. [Department of Radiation Oncology, Brigham & Women' s Hospital/Dana-Farber Cancer Institute, Boston, Massachusetts (United States); Erickson, Beth [Department Radiation Oncology, Froedtert Hospital and Medical College of Wisconsin, Milwaukee, Wisconsin (United States); Small, Christina [Department of Public Health Sciences, Stritch School of Medicine, Loyola University Chicago, Chicago, Illinois (United States); Small, William [Department of Radiation Oncology, Stritch School of Medicine, Loyola University Chicago, Chicago, Illinois (United States); Viswanathan, Akila N. [Department of Radiation Oncology, Brigham & Women' s Hospital/Dana-Farber Cancer Institute, Boston, Massachusetts (United States)

    2016-03-01

    Purpose: To provide an update of the 2007 American brachytherapy survey on image-based brachytherapy, which showed that in the setting of treatment planning for gynecologic brachytherapy, although computed tomography (CT) was often used for treatment planning, most brachytherapists used point A for dose specification. Methods and Materials: A 45-question electronic survey on cervical cancer brachytherapy practice patterns was sent to all American Brachytherapy Society members and additional radiation oncologists and physicists based in the United States between January and September 2014. Responses from the 2007 survey and the present survey were compared using the χ{sup 2} test. Results: There were 370 respondents. Of those, only respondents, not in training, who treat more than 1 cervical cancer patient per year and practice in the United States, were included in the analysis (219). For dose specification to the target (cervix and tumor), 95% always use CT, and 34% always use MRI. However, 46% use point A only for dose specification to the target. There was a lot of variation in parameters used for dose evaluation of target volume and normal tissues. Compared with the 2007 survey, use of MRI has increased from 2% to 34% (P<.0001) for dose specification to the target. Use of volume-based dose delineation to the target has increased from 14% to 52% (P<.0001). Conclusion: Although use of image-based brachytherapy has increased in the United States since the 2007 survey, there is room for further growth, particularly with the use of MRI. This increase may be in part due to educational initiatives. However, there is still significant heterogeneity in brachytherapy practice in the United States, and future efforts should be geared toward standardizing treatment.

  2. Low dose rate Ir-192 interstitial brachytherapy for prostate cancer

    Energy Technology Data Exchange (ETDEWEB)

    Oki, Yosuke; Dokiya, Takushi; Yorozu, Atsunori; Suzuki, Takayuki; Saito, Shiro; Monma, Tetsuo; Ohki, Takahiro [National Tokyo Medical Center (Japan); Murai, Masaru; Kubo, Atsushi

    2000-04-01

    From December 1997 through January 1999, fifteen prostatic cancer patients were treated with low dose rate Ir-192 interstitial brachytherapy using TRUS and perineal template guidance without external radiotherapy. Up to now, as no apparent side effects were found, the safety of this treatment is suggested. In the future, in order to treat prostatic cancer patients with interstitial brachytherapy using I-125 or Pd-103, more investigation for this low dose rate Ir-192 interstitial brachytherapy is needed. (author)

  3. Modelo experimental de bandagem ajustável do tronco pulmonar para preparo rápido do ventrículo

    Directory of Open Access Journals (Sweden)

    DIAS Carlos A.

    2000-01-01

    Full Text Available OBJETIVO: Um dispositivo de bandagem do tronco pulmonar (TP com ajuste percutâneo foi desenvolvido com o objetivo de induzir a hipertrofia rápida do ventrículo subpulmonar. MATERIAL E MÉTODOS: Consiste de um manguito de silicone insuflável percutaneamente, através de um botão de silicone auto-selante. Os corações de 7 cabritos jovens (peso médio: 8,7 kg foram submetidos à sobrecarga sistólica imposta pelo dispositivo e avaliados sob os aspectos hemodinâmicos, ecocardiográficos e morfológicos. Foram extraídas biópsias basais do miocárdio do ventrículo direito (VD para análise microscópica (perímetro e área do miócito. O dispositivo foi implantado no TP. As pressões do VD, TP e aorta foram monitorizadas. Após convalescença, foi iniciado o protocolo de insuflação do dispositivo de bandagem do TP. Foi injetada água destilada no botão auto-selante (via percutânea, até que a pressão sistólica do VD atingisse 70% da pressão sistólica do VE. As avaliações ecocardiográfica e hemodinâmica foram realizadas a cada 24 horas. A sobrecarga sistólica do VD foi mantida por um período de 96 horas, com insuflações progressivas no limite máximo tolerado, a cada 24 horas. Após esse período, os animais foram sacrificados para análise morfológica dos corações. Outros 9 cabritos (peso médio: 7,7 kg foram utilizados como grupo controle, para análise do peso do VD. RESULTADOS: Após 96 horas de sobrecarga sistólica do VD, foi observado um aumento do gradiente sistólico VD/TP de 10,1±4,3 mmHg para 60,0±11,0 mmHg e da pressão sistólica no VD de 22,4±4,1 mmHg para 71,0±10,0 mmHg (p<0,0001. O ecocardiograma revelou aumento da espessura muscular do VD, de 4,4±0,5 mm para 7,3±1,7 mm (p=0,001. Quando comparado ao grupo controle, houve um ganho de peso de 74% do VD submetido à sobrecarga sistólica (p<0,0001. À microscopia óptica, foi observado aumento de 27% no perímetro e de 69% na área dos miócitos (p=0

  4. Modelos para ajuste da produção de gases em silagens de girassol e milho Models for fit of gas production in sunflower and corn silages

    Directory of Open Access Journals (Sweden)

    Renius Mello

    2008-02-01

    Full Text Available O objetivo deste trabalho foi identificar entre os modelos Brody, Von Bertalanffy, Gompertz, France, Logístico, Logístico modificado e Logístico bicompartimental, aquele que apresenta maior qualidade de ajuste à curva de produção cumulativa de gases em silagens de girassol e milho. Os critérios adotados foram: coeficiente de determinação, quadrado médio do resíduo, análise gráfica das curvas observadas e estimadas, análise gráfica de dispersão dos resíduos estudentizados, erro percentual médio, eficiência relativa e número de iterações para atingir a convergência. Os modelos Brody, France e Logístico bicompartimental apresentaram os maiores valores de coeficiente de determinação em ambos os substratos, e a diferença entre eles pode ser considerada desprezível. Estes modelos apresentaram, também, os menores valores de quadrado médio do resíduo em silagens de girassol, e a diferença entre eles foi considerada desprezível. Os modelos Brody e France apresentaram menor quadrado médio do resíduo em silagens de milho. Todos os modelos apresentaram dispersão positiva dos resíduos em ambos os substratos após 144 horas de incubação. O modelo Brody apresentou menor erro percentual médio e número de iterações em ambos os substratos. Os modelos Logístico bicompartimental e France apresentaram maior eficiência relativa, respectivamente, em silagens de girassol e milho. Assim, o modelo Logístico bicompartimental apresenta maior qualidade de ajuste à curva de produção de gases em silagens de girassol e milho.The aim of this work was to identify among the Brody, Von Bertalanffy, Gompertz, France, Logistic, Modified logistic and Dual-pool logistic models, the one that presents the highest quality of fit for cumulative gas production curve in sunflower and corn silages. The quality of fit was evaluated by coefficient of determination, residual mean square, graphic analysis of the observed and estimated curves

  5. A comparison of complications between ultrasound-guided prostate brachytherapy and open prostate brachytherapy

    International Nuclear Information System (INIS)

    Benoit, Ronald M.; Naslund, Michael J.; Cohen, Jeffrey K.

    2000-01-01

    Purpose: Prostate brachytherapy has reemerged during the 1990s as a treatment for clinically localized prostate cancer. The renewed popularity of prostate brachytherapy is largely due to the use of transrectal ultrasound of the prostate, which allows for more accurate isotope placement within the prostate when compared to the open approach. The present study investigates whether this improved cancer control is at the expense of increased morbidity by comparing the morbidity after transrectal ultrasound-guided prostate brachytherapy to the morbidity after prostate brachytherapy performed via an open approach. Methods and Materials: All men in the Medicare population who underwent prostate brachytherapy in the year 1991 were identified. These men were further stratified into those men who underwent prostate brachytherapy via an open approach and the men who underwent prostate brachytherapy with ultrasound guidance. All subsequent inpatient, outpatient, and physician (Part B) Medicare claims for these men from the years 1991-1993 were then analyzed to determine outcomes. Results: In the year 1991, 2124 men in the Medicare population underwent prostate brachytherapy. An open approach was used in 715 men (33.7%), and ultrasound guidance was used in 1409 men (66.3%). Mean age for both cohorts was 73.7 years with a range of 50.7-92.8 years for the ultrasound group and 60.6-92.1 years for the open group. A surgical procedure for the relief of bladder outlet obstruction was performed in 122 men (8.6%) in the ultrasound group and in 54 men (7.6%) in the open group. An artificial urinary sphincter was placed in 2 men (0.14%) in the ultrasound group and in 2 men (0.28%) in the open group. A penile prosthesis was implanted in 10 men (0.71%) in the ultrasound group and in 4 men (0.56%) in the open group. A diagnosis code for urinary incontinence was carried by 95 men (6.7%) in the ultrasound group and by 45 men (6.3%) in the open group. A diagnosis code for erectile dysfunction

  6. Rectal fistulas after prostate brachytherapy

    International Nuclear Information System (INIS)

    Tran, Audrey; Wallner, Kent; Merrick, Gregory; Seeberger, Jergen M.S.; Armstrong, Julius R.T.T.; Mueller, Amy; Cavanagh, William M.S.; Lin, Daniel; Butler, Wayne

    2005-01-01

    Purpose: To compare the rectal and prostatic radiation doses for a prospective series of 503 patients, 44 of whom developed persistent rectal bleeding, and 2 of whom developed rectal-prostatic fistulas. Methods and Materials: The 503 patients were randomized and treated by implantation with 125 I vs. 103 Pd alone (n = 290) or to 103 Pd with 20 Gy vs. 44 Gy supplemental external beam radiotherapy (n = 213) and treated at the Puget Sound Veterans Affairs Medical Center (n = 227), Schiffler Cancer Center (n 242) or University of Washington (n = 34). Patients were treated between September 1998 and October 2001 and had a minimum of 24 months of follow-up. The patient groups were treated concurrently. Treatment-related morbidity was monitored by mailed questionnaires, using standard American Urological Association and Radiation Therapy Oncology Group criteria, at 1, 3, 6, 12, 18, and 24 months. Patients who reported Grade 1 or greater Radiation Therapy Oncology Group rectal morbidity were interviewed by telephone to clarify details regarding their rectal bleeding. Those who reported persistent bleeding, lasting for >1 month were included as having Grade 2 toxicity. Three of the patients with rectal bleeding required a colostomy, two of whom developed a fistula. No patient was lost to follow-up. The rectal doses were defined as the rectal volume in cubic centimeters that received >50%, 100%, 200%, or 300% of the prescription dose. The rectum was considered as a solid structure defined by the outer wall, without attempting to differentiate the inner wall or contents. Results: Persistent rectal bleeding occurred in 44 of the 502 patients, 32 of whom (73%) underwent confirmatory endoscopy. In univariate analysis, multiple parameters were associated with late rectal bleeding, including all rectal brachytherapy indexes. In multivariate analysis, however, only the rectal volume that received >100% of the dose was significantly predictive of bleeding. Rectal fistulas occurred

  7. Ajuste de modelos estocásticos lineares e não-lineares para a descrição do perfil longitudinal de árvores Fitting linear and nonlinear stochastic models to describe longitudinal tree profile

    Directory of Open Access Journals (Sweden)

    Leonardo Machado Pires

    2007-10-01

    Full Text Available Os modelos polinomiais são mais difundidos no meio florestal brasileiro na descrição do perfil de árvores devido à sua facilidade de ajuste e precisão. O mesmo não ocorre com os modelos não-lineares, os quais possuem maior dificuldade de ajuste. Dentre os modelos não-lineares clássicos, na descrição do perfil, podem-se citar o de Gompertz, o Logístico e o de Weibull. Portanto, este estudo visou comparar os modelos lineares e não lineares para a descrição do perfil de árvores. As medidas de comparação foram o coeficiente de determinação (R², o erro-padrão residual (s yx, o coeficiente de determinação corrigido (R²ajustado, o gráfico dos resíduos e a facilidade de ajuste. Os resultados ressaltaram que, dentre os modelos não-lineares, o que obteve melhor desempenho, de forma geral, foi o modelo Logístico, apesar de o modelo de Gompertz ser melhor em termos de erro-padrão residual. Nos modelos lineares, o polinômio proposto por Pires & Calegario foi superior aos demais. Ao comparar os modelos não-lineares com os lineares, o modelo Logístico foi melhor em razão, principalmente, do fato de o comportamento dos dados ser não-linear, à baixa correlação entre os parâmetros e à fácil interpretação deles, facilitando a convergência e o ajuste.Polynomial models are most commonly used in Brazilian forestry for taper modeling due to its straightforwardly fitting and precision. The use of nonlinear regression classic models, like Gompertz, Logistic and Weibull, is not very common in Brazil. Therefore, this study aimed to verify the best nonlinear and linear models, and among these the best model to describe the longitudinal tree profile. The comparison measures were: R², syx, R²adjusted, residual graphics and fitting convergence. The results pointed out that among the non-linear models the best behavior, in general, was given by the Logistic model, although the Gompertz model was superior compared with the Weibull

  8. Patterns of care for brachytherapy in Europe. Results in Spain.

    Science.gov (United States)

    López Torrecilla, J; Guedea, F; Heeren, G; Nissin, R; Ellison, T; Cottier, B

    2006-05-01

    In 2003 ESTRO began a project whose primary objective, was to make a map in the European area of infrastructures in technology and personnel for brachytherapy. A survey and a web site were elaborated. The survey was sent to the 76 Spanish Radiation Oncology departments in May 2003. By the end of 2003, 66 (86.8%) services had responded, 40 (71.4%) of which had brachytherapy. The services with brachytherapy treated 73.5% of the total patients, an average of 1,199 patients. The mean number of patients treated with brachytherapy by department was 135.5 and the number of applications was 265 annually. The average number of specialists was 7, 4 of them trained in brachytherapy. The average weekly work load of the radiation oncologists, physicists, and technicians was 22.6 h, 13.8 h and 21.0 h, respectively. The mean time dedicated to each patient by radiation oncologists, physicists and technicians was 9.2 h; 6.19 h; 7.2 h, respectively. The total number of afterloaders was 43 (22 HDR, 18 LDR, 3 PDR). The tumours most frequently treated with brachytherapy were gynaecological (56.24%), breast (14.2%) and prostate (11.7%). High dose rate was used in 47.46% of the patients and low dose rate in 47.24%. Between 1997 and 2002 there was an increase of 50.53% in patients treated with brachytherapy. The survey shows the brachytherapy resources and activity in Spain up to 2003. Increased use of brachytherapy in prostate tumours, prevalence of gynaecology brachytherapy and similar number of treatments with HDR and LDR are demonstrated in the Patterns of Care of Brachytherapy in Europe (PCBE) study in Spain.

  9. Sexual function after permanent prostate brachytherapy

    International Nuclear Information System (INIS)

    Galbreath, R.W.; Merrick, G.S.; Butler, W.M.; Stipetich, R.L.; Abel, L.J.; Lief, J.H.

    2001-01-01

    Purpose: To determine the incidence of potency preservation following permanent prostate brachytherapy and to evaluate the effect of multiple clinical and treatment parameters on penile erectile function. Materials and Methods: 425 patients underwent permanent prostate brachytherapy from April 1995 to October 1999. 209 patients who were potent prior to brachytherapy and currently not receiving hormonal manipulation were mailed an International Index of Erectile Function (IIEF) questionnaire with a pre-addressed stamped envelope. 180 patients completed and returned the questionnaire. Median patient follow-up was 39 months (range 18-74 months). Pre-implant erectile function was assigned using a three-tiered scoring system (2 = erections always or nearly always sufficient for vaginal penetration; 1 = erections sufficient for vaginal penetration but considered suboptimal; 0 = the inability to obtain erections and/or erections inadequate for vaginal penetration). Post-implant potency was defined as an IIEF score >11. Clinical parameters evaluated for sexual function included patient age, clinical T stage, elapsed time since implantation, hypertension, diabetes mellitus, and tobacco consumption. Evaluated treatment parameters included the utilization of neoadjuvant hormonal manipulation and the choice of isotope. The efficacy of sildenafil citrate in brachytherapy induced erectile dysfunction (ED) was also evaluated. Results: A pre-treatment erectile function score of 2 and 1 were assigned to 126 and 54 patients respectively. With 6 year follow up, 39% of patients maintained potency following prostate brachytherapy with a plateau on the curve. Post-implant preservation of potency (IIEF>11) correlated with pre-implant erectile function (50% versus 14% for pre-implant scores of 2 and 1 respectively, p≤0.0001), patient age (56%, 38%, and 23% for patients <60 years of age, 60-69 years of age, and ≥70 years of age respectively, p=0.012) and a history of diabetes mellitus

  10. The evolution of brachytherapy treatment planning

    International Nuclear Information System (INIS)

    Rivard, Mark J.; Venselaar, Jack L. M.; Beaulieu, Luc

    2009-01-01

    Brachytherapy is a mature treatment modality that has benefited from technological advances. Treatment planning has advanced from simple lookup tables to complex, computer-based dose-calculation algorithms. The current approach is based on the AAPM TG-43 formalism with recent advances in acquiring single-source dose distributions. However, this formalism has clinically relevant limitations for calculating patient dose. Dose-calculation algorithms are being developed based on Monte Carlo methods, collapsed cone, and solving the linear Boltzmann transport equation. In addition to improved dose-calculation tools, planning systems and brachytherapy treatment planning will account for material heterogeneities, scatter conditions, radiobiology, and image guidance. The AAPM, ESTRO, and other professional societies are working to coordinate clinical integration of these advancements. This Vision 20/20 article provides insight into these endeavors.

  11. Radiochromic dye film studies for brachytherapy applications

    International Nuclear Information System (INIS)

    Martinez-Davalos, A.; Rodriguez-Villafuerte, M.; Diaz-Perches, R.; Arzamendi-Perez, S.

    2002-01-01

    Commercial radiochromic dye films have been used in recent years to quantify absorbed dose in several medical applications. In this study we present the characterisation of the GafChromic MD-55-2 dye film, a double sensitive layer film suitable for photon irradiation in brachytherapy applications. Dose measurements were carried out with a low dose rate 137 Cs brachytherapy source, which produces very steep dose gradients in its vicinity, and therefore requires the capability of producing high spatial resolution isodose curves. Quantification of the dose rate in water per unit air kerma strength was obtained using a high-resolution transmission commercial scanner (Agfa DuoScan T1200) with the capability of digitising up to 600 x 1200 pixels per inch using 36 bits per pixel, together with optical density measurements. The Monte Carlo calculations and experimental measurements compared well in the 0-50 Gy dose interval used in this study. (author)

  12. Brachytherapy needle deflection evaluation and correction

    International Nuclear Information System (INIS)

    Wan Gang; Wei Zhouping; Gardi, Lori; Downey, Donal B.; Fenster, Aaron

    2005-01-01

    In prostate brachytherapy, an 18-gauge needle is used to implant radioactive seeds. This thin needle can be deflected from the preplanned trajectory in the prostate, potentially resulting in a suboptimum dose pattern and at times requiring repeated needle insertion to achieve optimal dosimetry. In this paper, we report on the evaluation of brachytherapy needle deflection and bending in test phantoms and two approaches to overcome the problem. First we tested the relationship between needle deflection and insertion depth as well as whether needle bending occurred. Targeting accuracy was tested by inserting a brachytherapy needle to target 16 points in chicken tissue phantoms. By implanting dummy seeds into chicken tissue phantoms under 3D ultrasound guidance, the overall accuracy of seed implantation was determined. We evaluated methods to overcome brachytherapy needle deflection with three different insertion methods: constant orientation, constant rotation, and orientation reversal at half of the insertion depth. Our results showed that needle deflection is linear with needle insertion depth, and that no noticeable bending occurs with needle insertion into the tissue and agar phantoms. A 3D principal component analysis was performed to obtain the population distribution of needle tip and seed position relative to the target positions. Our results showed that with the constant orientation insertion method, the mean needle targeting error was 2.8 mm and the mean seed implantation error was 2.9 mm. Using the constant rotation and orientation reversal at half insertion depth methods, the deflection error was reduced. The mean needle targeting errors were 0.8 and 1.2 mm for the constant rotation and orientation reversal methods, respectively, and the seed implantation errors were 0.9 and 1.5 mm for constant rotation insertion and orientation reversal methods, respectively

  13. Erectile Function Durability Following Permanent Prostate Brachytherapy

    International Nuclear Information System (INIS)

    Taira, Al V.; Merrick, Gregory S.; Galbreath, Robert W.; Butler, Wayne M.; Wallner, Kent E.; Kurko, Brian S.; Anderson, Richard; Lief, Jonathan H.

    2009-01-01

    Purpose: To evaluate long-term changes in erectile function following prostate brachytherapy. Methods and Materials: This study included 226 patients with prostate cancer and preimplant erectile function assessed by the International Index of Erectile Function-6 (IIEF-6) who underwent brachytherapy in two prospective randomized trials between February 2001 and January 2003. Median follow-up was 6.4 years. Pre- and postbrachytherapy potency was defined as IIEF-6 ≥ 13 without pharmacologic or mechanical support. The relationship among clinical, treatment, and dosimetric parameters and erectile function was examined. Results: The 7-year actuarial rate of potency preservation was 55.6% with median postimplant IIEF of 22 in potent patients. Potent patients were statistically younger (p = 0.014), had a higher preimplant IIEF (p < 0.001), were less likely to be diabetic (p = 0.002), and were more likely to report nocturnal erections (p = 0.008). Potency preservation in men with baseline IIEF scores of 29-30, 24-28, 18-23, and 13-17 were 75.5% vs. 73.6%, 51.7% vs. 44.8%, 48.0% vs. 40.0%, and 23.5% vs. 23.5% in 2004 vs. 2008. In multivariate Cox regression analysis, preimplant IIEF, hypertension, diabetes, prostate size, and brachytherapy dose to proximal penis strongly predicted for potency preservation. Impact of proximal penile dose was most pronounced for men with IIEF of 18-23 and aged 60-69. A significant minority of men who developed postimplant impotence ultimately regained erectile function. Conclusion: Potency preservation and median IIEF scores following brachytherapy are durable. Thoughtful dose sparing of proximal penile structures and early penile rehabilitation may further improve these results.

  14. Design and optimization of a brachytherapy robot

    Science.gov (United States)

    Meltsner, Michael A.

    Trans-rectal ultrasound guided (TRUS) low dose rate (LDR) interstitial brachytherapy has become a popular procedure for the treatment of prostate cancer, the most common type of non-skin cancer among men. The current TRUS technique of LDR implantation may result in less than ideal coverage of the tumor with increased risk of negative response such as rectal toxicity and urinary retention. This technique is limited by the skill of the physician performing the implant, the accuracy of needle localization, and the inherent weaknesses of the procedure itself. The treatment may require 100 or more sources and 25 needles, compounding the inaccuracy of the needle localization procedure. A robot designed for prostate brachytherapy may increase the accuracy of needle placement while minimizing the effect of physician technique in the TRUS procedure. Furthermore, a robot may improve associated toxicities by utilizing angled insertions and freeing implantations from constraints applied by the 0.5 cm-spaced template used in the TRUS method. Within our group, Lin et al. have designed a new type of LDR source. The "directional" source is a seed designed to be partially shielded. Thus, a directional, or anisotropic, source does not emit radiation in all directions. The source can be oriented to irradiate cancerous tissues while sparing normal ones. This type of source necessitates a new, highly accurate method for localization in 6 degrees of freedom. A robot is the best way to accomplish this task accurately. The following presentation of work describes the invention and optimization of a new prostate brachytherapy robot that fulfills these goals. Furthermore, some research has been dedicated to the use of the robot to perform needle insertion tasks (brachytherapy, biopsy, RF ablation, etc.) in nearly any other soft tissue in the body. This can be accomplished with the robot combined with automatic, magnetic tracking.

  15. Procedures for calibration of brachytherapy sources

    International Nuclear Information System (INIS)

    Alfonso Laguardia, R.; Alonso Samper, J.L.; Morales Lopez, J.L.; Saez Nunez, D.G.

    1997-01-01

    Brachytherapy source strength verification is a responsibility of the user of these source, in fact of the Medical Physicists in charge of this issue in a Radiotherapy Service. The calibration procedures in the users conditions are shown. Specifics methods for source strength determination are recommended, both for High Dose Rate (HDR) sources with Remote Afterloading equipment and for Low Dose Rate sources. The The results of the calibration of HDR Remote After loaders are indicated

  16. Dosimetry in high dose rate endoluminal brachytherapy

    International Nuclear Information System (INIS)

    Uno, Takashi; Kotaka, Kikuo; Itami, Jun

    1994-01-01

    In endoluminal brachytherapy for the tracheobronchial tree, esophagus, and bile duct, a reference point for dose calculation has been often settled at 1 cm outside from the middle of source travel path. In the current study, a change in the ratio of the reference point dose on the convex to concave side (Dq/Dp) was calculated, provided the source travel path bends as is the case in most endoluminal brachytherapies. Point source was presumed to move stepwise at 1 cm interval from 4 to 13 locations. Retention time at each location was calculated by personal computer so as to deliver equal dose at 1 cm from the linear travel path. With the retention time remaining constant, the change of Dq/Dp was assessed by bending the source travel path. Results indicated that the length of the source travel path and radius of its curve influenced the pattern of change in Dq/Dp. Therefore, it was concluded that the difference in reference dose on the convex and concave side of the curved path is not negligible under certain conditions in endoluminal brachytherapy. In order to maintain the ratio more than 0.9, relatively greater radius was required when the source travel path was decreased. (author)

  17. Radioactive seed immobilization techniques for interstitial brachytherapy

    International Nuclear Information System (INIS)

    Yan, K.; Podder, T.; Buzurovic, I.; Hu, Y.; Dicker, A.; Valicenti, R.; Yu, Y.; Messing, E.; Rubens, D.; Sarkar, N.; Ng, W.

    2008-01-01

    In prostate brachytherapy, seeds can detach from their deposited sites and move locally in the pelvis or migrate to distant sites including the pulmonary and cardiac regions. Undesirable consequences of seed migration include inadequate dose coverage of the prostate and tissue irradiation effects at the site of migration. Thus, it is clinically important to develop seed immobilization techniques. We first analyze the possible causes for seed movement, and propose three potential techniques for seed immobilization: (1) surgical glue, (2) laser coagulation and (3) diathermy coagulation. The feasibility of each method is explored. Experiments were carried out using fresh bovine livers to investigate the efficacy of seed immobilization using surgical glue. Results have shown that the surgical glue can effectively immobilize the seeds. Evaluation of the radiation dose distribution revealed that the non-immobilized seed movement would change the planned isodose distribution considerably; while by using surgical glue method to immobilize the seeds, the changes were negligible. Prostate brachytherapy seed immobilization is necessary and three alternative mechanisms are promising for addressing this issue. Experiments for exploring the efficacy of the other two proposed methods are ongoing. Devices compatible with the brachytherapy procedure will be designed in future. (orig.)

  18. A fibre optic dosimeter customised for brachytherapy

    Energy Technology Data Exchange (ETDEWEB)

    Suchowerska, N. [Department of Radiation Oncology, Royal Prince Alfred Hospital, Camperdown, NSW 2050 (Australia); School of Physics, University of Sydney, NSW 2006 (Australia)], E-mail: Natalka@email.cs.nsw.gov.au; Lambert, J.; Nakano, T. [Department of Radiation Oncology, Royal Prince Alfred Hospital, Camperdown, NSW 2050 (Australia); School of Physics, University of Sydney, NSW 2006 (Australia); Law, S. [School of Physics, University of Sydney, NSW 2006 (Australia); Optical Fibre Technology Centre, University of Sydney, 206 National Innovation Centre, Australian Technology Park, Eveleigh, NSW 1430 (Australia); Elsey, J. [Bandwidth Foundry Pty Ltd, Australian Technology Park, NSW, 1430 (Australia); McKenzie, D.R. [School of Physics, University of Sydney, NSW 2006 (Australia)

    2007-04-15

    In-vivo dosimetry for brachytherapy cancer treatment requires a small dosimeter with a real time readout capability that can be inserted into the patient to determine the dose to critical organs. Fibre optic scintillation dosimeters, consisting of a plastic scintillator coupled to an optical fibre, are a promising dosimeter for this application. We have implemented specific design features to optimise the performance of the dosimeter for specific in-vivo dosimetry during brachytherapy. Two sizes of the BrachyFOD{sup TM} scintillation dosimeter have been developed, with external diameters of approximately 2 and 1 mm. We have determined their important dosimetric characteristics (depth dose relation, angular dependence, energy dependence). We have shown that the background signal created by Cerenkov and fibre fluorescence does not significantly affect the performance in most clinical geometries. The dosimeter design enables readout at less than 0.5 s intervals. The clinical demands of real time in-vivo brachytherapy dosimetry can uniquely be satisfied by the BrachyFOD{sup TM}.

  19. Permanent Prostate Brachytherapy in Prostate Glands 3

    International Nuclear Information System (INIS)

    Mayadev, Jyoti; Merrick, Gregory S.; Reed, Joshua R.; Butler, Wayne M.; Galbreath, Robert W.; Allen, Zachariah A.; Wallner, Kent E.

    2010-01-01

    Purpose: To investigate the dosimetry, treatment-related morbidity, and biochemical outcomes for brachytherapy in patients with prostate glands 3 . Methods and Materials: From November 1996 to October 2006, 104 patients with prostate glands 3 underwent brachytherapy. Multiple prostate, urethral, and rectal dosimetric parameters were evaluated. Treatment-related urinary and rectal morbidity were assessed from patient questionnaires. Cause-specific survival, biochemical progression-free survival, and overall survival were recorded. Results: The median patient age, follow up, and pre-treatment ultrasound volume was 64 years, 5.0 years and 17.6cm 3 , respectively. Median day 0 dosimetry was significant for the following: V100 98.5%, D90 126.1% and R100 <0.5% of prescription dose. The mean urethral and maximum urethral doses were 119.6% and 133.8% of prescription. The median time to International Prostate Symptom Score resolution was 4 months. There were no RTOG grade III or IV rectal complications. The cause-specific survival, biochemical progression-free survival, and overall survival rates were 100%, 92.5%, and 77.8% at 9 years. For biochemically disease-free patients, the median most recent postbrachytherapy PSA value was 0.02 ng/mL. Conclusion: Our results demonstrate that brachytherapy for small prostate glands is highly effective, with an acceptable morbidity profile, excellent postimplant dosimetry, acceptable treatment-related morbidity, and favorable biochemical outcomes.

  20. Brachytherapy treatment with high dose rate

    International Nuclear Information System (INIS)

    Santana Rodriguez, Sergio Marcelino; Rodriguez Rodriguez, Lissi Lisbet; Ciscal Chiclana, Onelio Alberto

    2009-01-01

    Retrospectively analyze results and prognostic factors of cervical cancer patients treated with radio concomitant cisplatin-based chemotherapy, radiation therapy combined modality. Methods: From January 2003 to December 2007, 198 patients with invasive cervical cancer were treated at the Oncology Department of Hospital Robau Celestino Hernandez (brachytherapy performed at INOR). The most common age group was 31 to 40 years. The histology in squamous cell carcinoma accounted for 84.3% of cases. The treatment consisted of external pelvic irradiation and vaginal brachytherapy, high dose rate. Concomitant chemotherapy consisted of cisplatin 40 mg/m2 weekly with a maximum of 70 mg for 5 weeks. Results: 66.2% of patients completed 5 cycles of chemotherapy. The median overall survival was 39 months, overall survival, disease-free survival and survival free of locoregional recurrence at 5 years of 78%, 76% and 78.6% respectively .. We found that clinical stage, histological type (adenocarcinoma worst outcome) were statistically related to level of response. Conclusions: Treatment with external pelvic radiation, brachytherapy and concurrent weekly cisplatin in patients with stage IIIB cervical cancer is feasible in the Chilean public health system, well tolerated and results comparable to international literature. (Author)

  1. Père ou pair? Décalages et ajustements co-énonciatifs

    Directory of Open Access Journals (Sweden)

    Christiane Préneron

    2010-12-01

    Full Text Available

    L’objet de notre analyse dialogique et co-énonciative concerne la forme prise par la relation entre un père et son fi ls au cours d’échanges verbaux. Dans cette dimension relationnelle, nous avons cherché plus particulièrement à éclairer le statut d’énonciateur que chacun octroie à lui-même et à l’autre. Les images qu’un père et un fi ls ont l’un de l’autre et les places qu’ils occupent dans le dialogue sont en partie déterminées par leur statut de père et d’enfant. Ces places ne confi gurent pas un mode relationnel homogène. Au contraire, cet extrait de corpus est frappant par la grande diversité d’attitudes adoptées par le père avec son enfant: tour à tour il lui donne des ordres, des permissions, le réconforte, joue avec lui, lui propose des défi s ou rivalise avec lui. Daniel peut entrer dans le jeu proposé par son père ou s’y opposer, se laisser guider ou refuser, mais aussi être à l’initiative par des demandes ou des jeux. C’est cette diversité que nous tentons de mettre au jour, sachant que certaines séquences se caractérisent plus particulièrement par des décalages entre les interlocuteurs, alors que d’autres conduisent à des ajustements. Si la diversité qui caractérise cet extrait ne saurait être étendue comme caractérisant toute interaction père/enfant, l’analyse qui en est faite peut servir de repère pour l’étude de nouvelles interactions parent/enfant.

  2. Técnica de suturas ajustables: Resultados Technique of adjustable sutures: Results

    Directory of Open Access Journals (Sweden)

    Lourdes R. Hernández Santos

    2001-06-01

    Full Text Available Se realizó un estudio sensorial y motor preoperatorio y posoperatorio a 84 pacientes que acudieron a la consulta de Visión Binocular con el diagnóstico de estrabismo horizontal a partir de los 13 años de edad. El método estadístico utilizado fue "t" o Chi cuadrado. Nos trazamos como objetivo determinar los resultados posoperatorios de la cirugía de estrabismo realizada con la técnica de suturas ajustables, que fueron los siguientes: el 61 % de los pacientes con exotropía y el 71,4 % con el diagnóstico de exotropía se encontraban en ortotropía a los 6 meses de la intervención. El 71,4 % de los pacientes con esotropía y el 83,3 % con el diagnóstico de esotropía se encontraban en ortotropía al año de la intervención. Esta técnica quirúrgica permite la modificación de la desviación en el posoperatorio inmediato.A preoperative and postoperative sensorial and motor study was conducted among 84 patients who received attention at the consultation room of Binocular Vision with the diagnosis of horizontal strabismus from the age of 13 years old on. The statistical method used was "t" or chi square test. Our objective was to determine the postoperative results of the strabismus surgery performed by the technique of adjustable sutures. The results were as follows: 61 % of the patients with exotropia and 71.4 % with the diagnosis of exotropia were in orthotropia 6 months after the operation. 71.4 % of the patients with exotropia and 83.3 % with the diagnosis of exotropia were in orthotropia a year after the operation. This surgical technique allows the modification of the deviation in the immediate postoperative.

  3. Image based brachytherapy planning with special reference to gynaecological cancers

    International Nuclear Information System (INIS)

    Kirisits, C.

    2008-01-01

    Cervical cancer is the most common cancer among women in India and one of the most frequent malignancies in Europe and in North America. In addition endometrium, vagina and vulva cancer are treated with brachytherapy. Especially for locally advanced cervix cancer the integration of image based brachytherapy planning into clinical routine is becoming a new standard for the future

  4. A robotic device for MRI-guided prostate brachytherapy

    NARCIS (Netherlands)

    Lagerburg, V.

    2008-01-01

    One of the treatment options for prostate cancer is brachytherapy with iodine-125 sources. In prostate brachytherapy a high radiation dose is delivered to the prostate with a steep dose fall off to critical surrounding organs. The implantation of the iodine sources is currently performed under

  5. Autonomia profissional dos professores

    OpenAIRE

    Guerra, Teresa P.; Veiga, Feliciano

    2007-01-01

    Este estudo pretendeu analisar as representações dos professores acerca da sua autonomia em contexto escolar, com recurso a uma amostra de 203 professores de ambos os sexos, pertencentes a escolas dos distritos de Lisboa, Setúbal, Leiria e Aveiro. Utilizou-se a Escala de Autonomia Profissional dos Professores (EAPP).

  6. Inteligencia emocional y ajuste psicosocial en la adolescencia: El papel de la percepción emocional

    Directory of Open Access Journals (Sweden)

    José M. Salguero

    2011-12-01

    Full Text Available La inteligencia emocional (IE, definida como la habilidad para percibir, usar, comprender y regular las emociones, se ha mostrado como una variable importante a la hora de explicar el ajuste psicosocial de las personas. Pese a ello, la mayor parte de la investigación en torno a la IE ha sido realizada con muestras de población adulta y son escasos los trabajos que, utilizando medidas de ejecución, exploren su papel en la adolescencia. El objetivo del presente estudio fue el de analizar la influencia de la percepción emocional, una de las habilidades recogidas dentro de la IE, sobre el ajuste personal y social de una muestra de adolescentes españoles. Un total de 255 alumnos completaron una tarea de ejecución diseñada para evaluar la percepción emocional en la adolescencia así como diferentes medidas de ajuste social y personal. Los resultados de los análisis de correlación y regresión mostraron cómo los adolescentes con una mayor habilidad para reconocer los estados emocionales de los demás informaron de mejores relaciones sociales con iguales y padres, menor tensión en sus relaciones sociales, así como de un mayor nivel de confianza y competencia percibida. Además, estos resultados se mantuvieron tras controlar los efectos de la edad, el sexo y la personalidad. Se discuten los resultados en el contexto de la investigación sobre la inteligencia emocional y se proponen implicaciones prácticas para el diseño de programas de prevención y tratamiento

  7. Os benefícios da hipoterapia nos ajustes posturais em crianças portadoras de paralisia cerebral

    OpenAIRE

    Daniela Carrogi Vianna; Maria Elisabete Salina Saldanha; Leide Masieiro Taques Moeckel Amaral

    2017-01-01

    Paralisia Cerebral é uma afecção encefálica que ocorre na fase maturacional, apresentando seqüelas variáveis, envolvendo desordens de postura e movimentos. Examinaram-se alterações posturais de pacientes portadores de Paralisia Cerebral durante e após a realização de Hipoterapia, observando ajustes posturais. Participaram oito crianças, entre 6 e 12 anos, com tetraparesia espástica, apresentando déficics das reações básicas de endireitamento, proteção e equilíbrio. Utilizou-se a Hipoterapia c...

  8. Ajuste psicosocial y vivencia de la adopción en niños/as adoptados/as internacionalmente

    OpenAIRE

    Reinoso Bernuz, Marta

    2013-01-01

    [esp] La adopción internacional ha adquirido en España unas muy notables dimensiones y el desarrollo y la adaptación de estos niños se ha convertido en un asunto de gran importancia. La presente tesis doctoral pretende contribuir al conocimiento en esta área y tiene por objetivo analizar el nivel de ajuste psicosocial, la vivencia de la adopción y el afrontamiento del estrés en la mediana infancia (8-12 años) de los niños adoptados internacionalmente en nuestro país. Esta tesis se con...

  9. COMPARACIÓN DE HABILIDADES SOCIALES Y AJUSTE PSICOLÓGICO EN NIÑOS MEXICANOS DE TRES CONDICIONES

    OpenAIRE

    Claudia González Fragoso; Amada Ampudia Rueda; Yolanda Guevara Benítez

    2014-01-01

    Las habilidades sociales en la infancia guardan una estrech a relación con aspectos como autoestima, ansiedad y depresión. Tales variables son indicadoras del ajuste psicológico, que puede alterarse en los niños que son víctimas de violencia o que viven en institucion es. Para contar con datos sobre niños mexicanos, el presente estudio exploratorio evaluó y comparó los niveles mostrados en habilidades sociales, autoestima, ansiedad y depresión en tres grupos de niños que se hallaban en cond...

  10. Brachytherapy in the treatment of cervical cancer: a review

    Directory of Open Access Journals (Sweden)

    Banerjee R

    2014-05-01

    Full Text Available Robyn Banerjee,1 Mitchell Kamrava21Department of Radiation Oncology, Tom Baker Cancer Centre, Calgary, Alberta, Canada; 2Department of Radiation Oncology, University of California Los Angeles, Los Angeles, CA, USAAbstract: Dramatic advances have been made in brachytherapy for cervical cancer. Radiation treatment planning has evolved from two-dimensional to three-dimensional, incorporating magnetic resonance imaging and/or computed tomography into the treatment paradigm. This allows for better delineation and coverage of the tumor, as well as improved avoidance of surrounding organs. Consequently, advanced brachytherapy can achieve very high rates of local control with a reduction in morbidity, compared with historic approaches. This review provides an overview of state-of-the-art gynecologic brachytherapy, with a focus on recent advances and their implications for women with cervical cancer.Keywords: cervical cancer, brachytherapy, image-guided brachytherapy

  11. Radiation Exposure Reduction to Brachytherapy Staff By Using Remote Afterloading

    International Nuclear Information System (INIS)

    Attalla, E.M.

    2005-01-01

    The radiation exposures to the personnel staff from patients with brachytherapy implants in a brachytherapy service were reviewed. Exposures to the brachytherapy personnel, as determined by Thermoluminescence Dosimeter (TLD) monitors, indicates a four-fold reduction in exposures after the implantation of the use of remote afterloading devices. Quarterly TLD monitor data for seven quarters prior to the use of remote afterloading devices demonstrate an average projected annual dose equivalent to the brachytherapy staff of 2543 Μ Sv. After the implantation of the remote afterloading devices, the quarterly TLD monitor data indicate an average dose equivalent per person of 153 Μ Sv. This is 76% reduction in exposure to brachytherapy personnel with the use of these devices

  12. Accelerated partial breast irradiation utilizing balloon brachytherapy techniques

    International Nuclear Information System (INIS)

    Strauss, Jonathan B.; Dickler, Adam

    2009-01-01

    To overcome the barriers to BCT, methods of PBI in the setting of breast conservation have been explored. The method of PBI with the longest published follow-up is multi-catheter interstitial brachytherapy. Balloon-based brachytherapy with the MammoSite brachytherapy applicator was designed to simplify the brachytherapy procedure for PBI, enhance the reproducibility of the dosimetry, and improve patient comfort. The rates of local recurrence following PBI with the MammoSite applicator have been low, but there are few published reports and follow-up has been relatively short. The cosmetic outcomes and toxicity of MammoSite PBI are comparable to those seen after multicatheter-based PBI. Additional methods of balloon brachytherapy, including Xoft and SenoRx Contura have been developed. Finally, long-term follow-up after PBI is important for the welfare of individual patients and in order to establish the efficacy, late toxicity and cosmetic outcomes of this technique.

  13. Brachytherapy in the treatment of head and neck cancer

    International Nuclear Information System (INIS)

    Yoo, Seong Yul

    1999-01-01

    Brachytherapy has been proved to be an effective method for the purpose of increasing radiation dose to the tumor and reducing the dose to the surrounding normal tissue. In head and neck cancer, the rationale of brachytherapy is as follows; Firstly, early small lesion is radiocurative and the major cause of failure is local recurrence. Secondly, it can diminish evidently the dose to the normal tissue especially masseteric muscle and salivary gland. Thirdly, the anatomy of head and neck is suitable to various technique of brachytherapy. On background of accumulated experience of LDR iridium brachytherapy of head and neck cancer for the last 15 years, the author reviewed the history of radioisotope therapy, the characteristics of radionuclides, and some important things in the method, clinical technique and treatment planning. The author analyzed the clinical result of 185 cases of head and neck cancer treated in the Korea Cancer Center Hospital. Finally the future prospect of brachytherapy of head and neck cancer is discussed

  14. Directional interstitial brachytherapy from simulation to application

    Science.gov (United States)

    Lin, Liyong

    Organs at risk (OAR) are sometimes adjacent to or embedded in or overlap with the clinical target volume (CTV) to be treated. The purpose of this PhD study is to develop directionally low energy gamma-emitting interstitial brachytherapy sources. These sources can be applied between OAR to selectively reduce hot spots in the OARs and normal tissues. The reduction of dose over undesired regions can expand patient eligibility or reduce toxicities for the treatment by conventional interstitial brachytherapy. This study covers the development of a directional source from design optimization to construction of the first prototype source. The Monte Carlo code MCNP was used to simulate the radiation transport for the designs of directional sources. We have made a special construction kit to assemble radioactive and gold-shield components precisely into D-shaped titanium containers of the first directional source. Directional sources have a similar dose distribution as conventional sources on the treated side but greatly reduced dose on the shielded side, with a sharp dose gradient between them. A three-dimensional dose deposition kernel for the 125I directional source has been calculated. Treatment plans can use both directional and conventional 125I sources at the same source strength for low-dose-rate (LDR) implants to optimize the dose distributions. For prostate tumors, directional 125I LDR brachytherapy can potentially reduce genitourinary and gastrointestinal toxicities and improve potency preservation for low risk patients. The combination of better dose distribution of directional implants and better therapeutic ratio between tumor response and late reactions enables a novel temporary LDR treatment, as opposed to permanent or high-dose-rate (HDR) brachytherapy for the intermediate risk T2b and high risk T2c tumors. Supplemental external-beam treatments can be shortened with a better brachytherapy boost for T3 tumors. In conclusion, we have successfully finished the

  15. Penile brachytherapy: Results for 49 patients

    International Nuclear Information System (INIS)

    Crook, Juanita M.; Jezioranski, John; Grimard, Laval; Esche, Bernd; Pond, G.

    2005-01-01

    Purpose: To report results for 49 men with squamous cell carcinoma (SCC) of the penis treated with primary penile interstitial brachytherapy at one of two institutions: the Ottawa Regional Cancer Center, Ottawa, and the Princess Margaret Hospital, Toronto, Ontario, Canada. Methods and Materials: From September 1989 to September 2003, 49 men (mean age, 58 years; range, 22-93 years) had brachytherapy for penile SCC. Fifty-one percent of tumors were T1, 33% T2, and 8% T3; 4% were in situ and 4% Tx. Grade was well differentiated in 31%, moderate in 45%, and poor in 2%; grade was unspecified for 20%. One tumor was verrucous. All tumors in Toronto had pulsed dose rate (PDR) brachytherapy (n = 23), whereas those in Ottawa had either Iridium wire (n 22) or seeds (n = 4). Four patients had a single plane implant with a plastic tube technique, and all others had a volume implant with predrilled acrylic templates and two or three parallel planes of needles (median, six needles). Mean needle spacing was 13.5 mm (range, 10-18 mm), mean dose rate was 65 cGy/h (range, 33-160 cGy/h), and mean duration was 98.8 h (range, 36-188 h). Dose rates for PDR brachytherapy were 50-61.2 cGy/h, with no correction in total dose, which was 60 Gy in all cases. Results: Median follow-up was 33.4 months (range, 4-140 months). At 5 years, actuarial overall survival was 78.3% and cause-specific survival 90.0%. Four men died of penile cancer, and 6 died of other causes with no evidence of recurrence. The cumulative incidence rate for never having experienced any type of failure at 5 years was 64.4% and for local failure was 85.3%. All 5 patients with local failure were successfully salvaged by surgery; 2 other men required penectomy for necrosis. The soft tissue necrosis rate was 16% and the urethral stenosis rate 12%. Of 8 men with regional failure, 5 were salvaged by lymph node dissection with or without external radiation. All 4 men with distant failure died of disease. Of 49 men, 42 had an intact

  16. Erectile function after permanent prostate brachytherapy

    International Nuclear Information System (INIS)

    Merrick, Gregory S.; Butler, Wayne M.; Galbreath, Robert W.; Stipetich, Robin L.; Abel, Laurie J.; Lief, Jonathan H.

    2002-01-01

    Purpose: To determine the incidence of potency preservation after permanent prostate brachytherapy using a validated patient-administered questionnaire and to evaluate the effect of multiple clinical and treatment parameters on penile erectile function. Methods and Materials: Four hundred twenty-five patients underwent permanent prostate brachytherapy from April 1995 to October 1999. Two hundred nine patients who were potent before brachytherapy and who at the time of the survey were not receiving hormonal therapy were mailed the specific erectile questions of the International Index of Erectile Function (IIEF) questionnaire with a self-addressed stamped envelope. The questionnaire consisted of 5 questions, with a maximal score of 25. Of the 209 patients, 181 (87%) completed and returned the questionnaire. The mean and median follow-up was 40.4±14.9 and 40.6 months, respectively (range 19-75). Preimplant erectile function was assigned using a three-tiered scoring system (2 = erections always or nearly always sufficient for vaginal penetration; 1 = erections sufficient for vaginal penetration but considered suboptimal; 0 = the inability to obtain erections and/or erections inadequate for vaginal penetration). Postimplant potency was defined as an IIEF score ≥11. The clinical parameters evaluated for erectile function included patient age, preimplant potency, clinical T-stage, pretreatment prostate-specific antigen level, Gleason score, elapsed time after implantation, hypertension, diabetes mellitus, and tobacco consumption. Treatment parameters included radiation dose to the prostate gland, use of hormonal manipulation, use of supplemental external beam radiotherapy (EBRT), choice of isotope, prostate volume, and planning volume. The efficacy of sildenafil citrate in brachytherapy-induced erectile dysfunction (ED) was also evaluated. Results: Pretreatment erectile function scores of 2 and 1 were assigned to 125 and 56 patients, respectively. With a 6-year follow

  17. Ajuste psicosocial en agresores, víctimas puras y víctimas agresivas en la escuela. Psychosocial adjustment in aggressors, pure victims and aggressive

    Directory of Open Access Journals (Sweden)

    Estefanía Estévez

    2008-07-01

    Full Text Available

    En el presente estudio se examinan las diferencias entre cuatro categorías de adolescentes –agresores, víctimas puras, víctimas agresivas y estudiantes no implicados en problemas comportamentales o de victimización en la escuela– en relación con la autoestima, la sintomatología depresiva, el estrés percibido, el sentimiento de soledad, y una medida general de satisfacción con la vida. Los participantes fueron 1.319 adolescentes con edades comprendidas entre los 11 y los 16 años (47% chicos y escolarizados en siete centros públicos de enseñanza secundaria ubicados en Valencia (España. Los análisis de varianza indicaron la existencia de diferencias significativas entre las cuatro categorías de estudiantes. Así, los adolescentes no implicados mostraron un mejor ajuste psicosocial general: niveles más elevados de autoestima y satisfacción con la vida y niveles inferiores de sintomatología depresiva, estrés percibido y sentimiento de soledad. Las puntuaciones en este grupo fueron equivalentes a aquellas obtenidas por los agresores con respecto a la autoestima, la sintomatología depresiva y la soledad. Sin embargo, los agresores percibieron más estrés y expresaron menor satisfacción con sus vidas, como así también hicieron los otros dos grupos, a saber: víctimas puras y víctimas agresivas. Las víctimas mostraron los niveles más elevados de sentimiento de soledad.

    Palabras clave: Agresor, víctima, víctima agresiva, violencia escolar, ajuste psicosocial.

    The present study examined differences among four categories of adolescents –aggressors, pure victims, aggressive victims, and students not involved in behavioural or victimization problems at school– with respect to self-esteem, depressive symptomatology, perceived stress, feeling of loneliness, and a general measure of satisfaction with life. Participants were 1,319 adolescents aged from 11 to 16 years old (47% male and drawn from seven state

  18. ALTAS HABILIDADES/SUPERDOTAÇÃO: um olhar para o desenvolvimento cognitivo, ajuste emocional e seus impactos na vida profissional

    Directory of Open Access Journals (Sweden)

    Alberto Padrón Abad

    2016-12-01

    El objetivo del presente artículo es analizar los factores de desarrollo cognitivo, ajuste emocional del individuo AH/SD y sus impactos en la vida profesional y laboral. La metodología empleada está basada en una investigación bibliográfica, exploratoria y descriptiva realizada a partir de referencias teóricas, referentes al tema, previamente analizadas y publicadas. En este sentido, se iniciará considerando los factores que facilitan el ajuste emocional de individuos AH/SD (familiares, escolares, laborales e interpersonales. Posteriormente, se analizará la pregunta: ¿por qué existen personas que a pesar de vivir en situaciones sociales y económicas desfavorables pueden desarrollar sus AH/SD y ser profesionales de éxito, mientras otros, con todas las oportunidades en la vida no llegan al éxito profesional ni contribuyen efectivamente con la sociedad? Con la intención de responder esa pregunta se estudiarán: el concepto de resiliencia, la Teoría de la Evaluación Cognitiva de Lazarus y la Teoría de la Desintegración Positiva de Dabrowski. De esta manera, se concluye la importancia de aplicar de manera efectiva los modelos teóricos ya propuestos, de modo comprensivo y explicativo, de las AH/SD acerca de los aspectos del desarrollo cognitivo y emocional de los individuos.

  19. Historia Funcional de Morfologías Lingüísticas y su Efecto en un Ajuste Convencional

    Directory of Open Access Journals (Sweden)

    Nataly Yáñez Ramírez

    2011-01-01

    Full Text Available Se observó si diferentes historias funcionales construidas durante la adquisición de un conjunto de morfologías lingüísticas facilitaban un ajuste convencional. Participaron 24 estudiantes universitarios distribuidos en tres grupos, expuestos a entrenamientos construidos bajo la lógica de diferentes niveles de interacción: contextual, suplementario o selector (Ribes y López, 1985; y posteriormente se evaluó su ejecución en una tarea convencional. El entrenamiento cuyo criterio de ajuste era de tipo selector fue la que más facilitó tanto la adquisición de las morfologías lingüísticas como su uso en la tarea, efecto que pareció más evidente en los hablantes que en los escuchas. No se encontraron diferencias entre los entrenamientos contextual y suplementario. Los resultados se discuten en términos de sus implicaciones teóricas y metodológicas.

  20. The american brachytherapy society recommendations for permanent prostate brachytherapy postimplant dosimetric analysis

    International Nuclear Information System (INIS)

    Nag, Subir; Bice, William; Wyngaert, Keith de; Prestidge, Bradley; Stock, Richard; Yu Yan

    2000-01-01

    Purpose: The purpose of this report is to establish guidelines for postimplant dosimetric analysis of permanent prostate brachytherapy. Methods: Members of the American Brachytherapy Society (ABS) with expertise in prostate dosimetry evaluation performed a literature review and supplemented with their clinical experience formulated guidelines for performing and analyzing postimplant dosimetry of permanent prostate brachytherapy. Results: The ABS recommends that postimplant dosimetry should be performed on all patients undergoing permanent prostate brachytherapy for optimal patient care. At present, computed tomography (CT)-based dosimetry is recommended, based on availability cost and the ability to image the prostate as well as the seeds. Additional plane radiographs should be obtained to verify the seed count. Until the ideal postoperative interval for CT scanning has been determined, each center should perform dosimetric evaluation of prostate implants at a consistent postoperative interval. This interval should be reported. Isodose displays should be obtained at 50%, 80%, 90%, 100%, 150%, and 200% of the prescription dose and displayed on multiple cross-sectional images of the prostate. A dose-volume histogram (DVH) of the prostate should be performed and the D 90 (dose to 90% of the prostate gland) reported by all centers. Additionally, the D 80, D 100, the fractional V 80, V 90, V 100, V 150, and V 200, (i.e., the percentage of prostate volume receiving 80%, 90%, 100%, 150%, and 200% of the prescribed dose, respectively), the rectal, and urethral doses should be reported and ultimately correlated with clinical outcome in the research environment. On-line real-time dosimetry, the effects of dose heterogeneity, and the effects of tissue heterogeneity need further investigation. Conclusion: It is essential that postimplant dosimetry should be performed on all patients undergoing permanent prostate brachytherapy. Guidelines were established for the performance

  1. Programa de ajuste multiparamétrico de curvas de titulação potenciométricas de ácidos húmicos Multiparametric adjustment program of potentiometric titration curves of humic acids

    Directory of Open Access Journals (Sweden)

    Clausius Duque Gonçalves Reis

    2010-04-01

    Full Text Available Tendo em vista a dificuldade de determinação dos pontos de inflexão na curva de titulação potenciométrica de ácidos húmicos, por metodologias tradicionais, foi desenvolvido foi desenvolvido um programa na linguagem Delphi para ajuste multiparamétrico de dados de titulação potenciométrica. Para isso um processo iterativo para estimar as raízes de um polinômio, com base no método de Newton-Raphson, foi utilizado. Os dados das titulações potenciométricas de ácidos húmicos usados nas regressões foram obtidos em um sistema automatizado de titulação potenciométrica. O programa desenvolvido na linguagem Delphi permite maior versatilidade e facilidade de operação, com uma interação mais amigável com o usuário. As curvas de titulação potenciométricas ajustadas sobrepuseram-se quase que totalmente às curvas experimentais. Os valores de pKa e as percentagens de grupos tituláveis dos ácidos húmicos, parâmetros ajustáveis na regressão multiparamétrica, apresentaram valores comparáveis com dados da literatura.Regarding the difficulty of determining the inflection points in the potentiometric titration curve of humic acids by means of traditional methodologies, a Delphi program a Delphi program was developed for the multiparametric data adjustment in potentiometric titration. For this purpose, an iterative process was used, based on the Newton-Raphson method to estimate the roots of a polynomial. The humic acid potentiometric titration data, used in regressions, were obtained in an automated system of potentiometric titration. The program developed in Delphi language features greater versatility, ease of operation and better interaction with the user. The adjusted potentiometric titration curves overlap the experimental curves almost entirely. The pKa values and percentages of titrable groups of humic acids extracted from soil, adjustable parameters in the multiparametric regression, were comparable with those reported

  2. Biology of dose rate in brachytherapy

    International Nuclear Information System (INIS)

    Brenner, David J.

    1995-01-01

    Purpose: This course is designed for practitioners and beginners in brachytherapy. The aim is to review biological principles underlying brachytherapy, to understand why current treatment regimes are the way they are, and to discuss what the future may hold in store. Brachytherapy has a long history. It was suggested as long ago as 1903 by Alexander Graham Bell, and the optimal application of this technique has been a subject of debate ever since. 'Brachy' means 'short', and the essential features of conventional brachytherapy are: positioning of the source a short distance from, or in, the tumor, allowing good dose distributions; short overall treatment times, to counter tumor repopulation; low dose rate, enabling a good therapeutic advantage between tumor control and damage to late-responding tissue. The advantages of good dose distributions speak for themselves; in some situations, as we shall see, computer-based dose optimization can be used to improve them still further. The advantages of short overall times stem from the fact that accelerated repopulation of the tumor typically begins a few weeks after the start of a radiation treatment. If all the radiation can be crammed in before that time, the risks of tumor repopulation can be considerably reduced. In fact even external-beam radiotherapy is moving in this direction, with the use of highly accelerated protocols. The advantages of low dose rate stem from the differential response to fractionation of early- and late-responding tissues. Essentially, lowering the dose rate spares late-responding tissue more than it does early-responding tissue such as tumors. We shall also discuss some recent innovations in the context of the general principles that have been outlined. For example, High dose rate brachytherapy, particularly for the uterine cervix: Does it work? If so, when and why? Use of Ir-192 sources, with a half life of 70 days: Should corrections be made for changing biological effectiveness as the dose

  3. Multihelix rotating shield brachytherapy for cervical cancer

    Energy Technology Data Exchange (ETDEWEB)

    Dadkhah, Hossein [Department of Biomedical Engineering, University of Iowa, 1402 Seamans Center for the Engineering Arts and Sciences, Iowa City, Iowa 52242 (United States); Kim, Yusung; Flynn, Ryan T., E-mail: ryan-flynn@uiowa.edu [Department of Radiation Oncology, University of Iowa, 200 Hawkins Drive, Iowa City, Iowa 52242 (United States); Wu, Xiaodong [Department of Radiation Oncology, University of Iowa, 200 Hawkins Drive, Iowa City, Iowa 52242 and Department of Electrical and Computer Engineering, University of Iowa, 4016 Seamans Center for the Engineering Arts and Sciences, Iowa City, Iowa 52242 (United States)

    2015-11-15

    Purpose: To present a novel brachytherapy technique, called multihelix rotating shield brachytherapy (H-RSBT), for the precise angular and linear positioning of a partial shield in a curved applicator. H-RSBT mechanically enables the dose delivery using only linear translational motion of the radiation source/shield combination. The previously proposed approach of serial rotating shield brachytherapy (S-RSBT), in which the partial shield is rotated to several angular positions at each source dwell position [W. Yang et al., “Rotating-shield brachytherapy for cervical cancer,” Phys. Med. Biol. 58, 3931–3941 (2013)], is mechanically challenging to implement in a curved applicator, and H-RSBT is proposed as a feasible solution. Methods: A Henschke-type applicator, designed for an electronic brachytherapy source (Xoft Axxent™) and a 0.5 mm thick tungsten partial shield with 180° or 45° azimuthal emission angles and 116° asymmetric zenith angle, is proposed. The interior wall of the applicator contains six evenly spaced helical keyways that rigidly define the emission direction of the partial radiation shield as a function of depth in the applicator. The shield contains three uniformly distributed protruding keys on its exterior wall and is attached to the source such that it rotates freely, thus longitudinal translational motion of the source is transferred to rotational motion of the shield. S-RSBT and H-RSBT treatment plans with 180° and 45° azimuthal emission angles were generated for five cervical cancer patients with a diverse range of high-risk target volume (HR-CTV) shapes and applicator positions. For each patient, the total number of emission angles was held nearly constant for S-RSBT and H-RSBT by using dwell positions separated by 5 and 1.7 mm, respectively, and emission directions separated by 22.5° and 60°, respectively. Treatment delivery time and tumor coverage (D{sub 90} of HR-CTV) were the two metrics used as the basis for evaluation and

  4. Caudal epidural anesthesia during intracavitary brachytherapy for cervical cancer

    International Nuclear Information System (INIS)

    Isoyama-Shirakawa, Yuko; Abe, Madoka; Nakamura, Katsumasa

    2015-01-01

    It has been suggested that pain control during intracavitary brachytherapy for cervical cancer is insufficient in most hospitals in Japan. Our hospital began using caudal epidural anesthesia during high-dose-rate (HDR) intracavitary brachytherapy in 2011. The purpose of the present study was to retrospectively investigate the effects of caudal epidural anesthesia during HDR intracavitary brachytherapy for cervical cancer patients. Caudal epidural anesthesia for 34 cervical cancer patients was performed during HDR intracavitary brachytherapy between October 2011 and August 2013. We used the patients' self-reported Numeric Rating Scale (NRS) score at the first session of HDR intracavitary brachytherapy as a subjective evaluation of pain. We compared NRS scores of the patients with anesthesia with those of 30 patients who underwent HDR intracavitary brachytherapy without sacral epidural anesthesia at our hospital between May 2010 and August 2011. Caudal epidural anesthesia succeeded in 33 patients (97%), and the NRS score was recorded in 30 patients. The mean NRS score of the anesthesia group was 5.17 ± 2.97, significantly lower than that of the control group's 6.80 ± 2.59 (P = 0.035). The caudal epidural block resulted in no side-effects. Caudal epidural anesthesia is an effective and safe anesthesia option during HDR intracavitary brachytherapy for cervical cancer. (author)

  5. Ajustes de funções de distribuição de probabilidade à radiação solar global no Estado do Rio Grande do Sul Adjustments of probability distribution functions to global solar radiation in Rio Grande do Sul State

    Directory of Open Access Journals (Sweden)

    Alberto Cargnelutti Filho

    2004-12-01

    Full Text Available O objetivo deste trabalho foi verificar o ajuste das séries de dados de radiação solar global média decendial, de 22 municípios do Estado do Rio Grande do Sul, às funções de distribuições de probabilidade normal, log-normal, gama, gumbel e weibull. Aplicou-se o teste de aderência de Kolmogorov-Smirnov, nas 792 séries de dados (22 municípios x 36 decêndios de radiação solar global média decendial, para verificar o ajuste dos dados às distribuições normal, log-normal, gama, gumbel e weibull, totalizando 3.960 testes. Os dados decendiais de radiação solar global média se ajustam às funções de distribuições de probabilidade normal, log-normal, gama, gumbel e weibull, e apresentam melhor ajuste à função de distribuição de probabilidade normal.The objective of this work was to verify the adjustment of data series for average global solar radiation to the normal, log-normal, gamma, gumbel and weibull probability distribution functions. Data were collected from 22 cities in Rio Grande do Sul State, Brazil. The Kolmogorov-Smirnov test was applied in the 792 series of data (22 localities x 36 periods of ten days of average global solar radiation to verify the adjustment of the data to the normal, log-normal, gamma, gumbel and weibull probability distribution functions, totalizing 3,960 tests. The data of average global solar radiation adjust to the normal, log-normal, gamma, gumbel and weibull probability distribution functions, and present a better adjustment to the normal probability function.

  6. Iridium-192 sources production for brachytherapy use

    International Nuclear Information System (INIS)

    Rostelato, Maria Elisa Chuery Martins

    1997-01-01

    The incidence of cancer increases every year in Brazil and turns out to be one of the most important causes of mortality. Some of the patients are treated with brachytherapy, a form of lesion treatment which is based on the insertion of sources into tumors, in this particular case, activated iridium wires. During this process, the ionizing radiation efficiently destroys the malignant cells. These iridium wires have a nucleus made out of an iridium-platinum alloy 20-30/70-80 of 0,1 mm in diameter either coated by platinum or encased in a platinum tube. The technique consists in irradiating the wire in the reactor neutron flux in order to produce iridium-192. The linear activity goes from 1 mCi/cm to 4 mCi/cm and the basic characteristic, which is required, is the homogeneity of the activation along the wire. It should not present a dispersion exceeding 5% on a wire measuring 50 cm in length, 0.5 mm or 0.3 mm in diameter. Several experiments were carried out in order to define the activation parameters. Wires from different origins were analyzed. It was concluded that United States of America and France wires were found to be perfectly adequate for brachytherapy purposes and have therefore been sent to specialized hospitals and successfully applied to cancer patients. Considering that the major purpose of this work is to make this product more accessible in Brazil, at a cost reflecting the Brazilian reality, the IPEN is promoting the preparation of iridium-192 sources to be used in brachytherapy, on a national level. (author)

  7. Perioperative interstitial brachytherapy for recurrent keloid scars

    International Nuclear Information System (INIS)

    Rio, E.; Bardet, E.; Peuvrel, P.; Martinet, L.; Perrot, P.; Baraer, F.; Loirat, Y.; Sartre, J.Y.; Malard, O.; Ferron, C.; Dreno, B.

    2010-01-01

    Purpose: Evaluation of the results of perioperative interstitial brachytherapy with low dose-rate (L.D.R.) Ir-192 in the treatment of keloid scars. Patients and methods: We performed a retrospective analysis of 73 histologically confirmed keloids (from 58 patients) resistant to medico surgical treated by surgical excision plus early perioperative brachytherapy. All lesions were initially symptomatic. Local control was evaluated by clinical evaluation. Functional and cosmetic results were assessed in terms of patient responses to a self-administered questionnaire. Results: Median age was 28 years (range 13-71 years). Scars were located as follows: 37% on the face, 32% on the trunk or abdomen, 16% on the neck, and 15% on the arms or legs. The mean delay before loading was four hours (range, 1-6 h). The median dose was 20 Gy (range, 15-40 Gy). Sixty-four scars (from 53 patients) were evaluated. Local control was 86% (follow-up, 44.5 months; range, 14-150 months). All relapses occurred early within 2 years posttreatment. At 20 months, survival without recurrence was significantly lower when treated lengths were more than 6 cm long. The rate was 100% for treated scars below 4.5 cm in length, 95% (95% CI: 55-96) for those 4.5-6 cm long, and 75% (95% CI: 56-88) beyond 6 cm (p = 0.038). Of the 35 scars (28 patients) whose results were reassessed, six remained symptomatic and the esthetic results were considered to be good in 51% (18/35) and average in 37% (13/35) (median follow-up, 70 months; range, 16-181 months). Conclusion: Early perioperative L.D.R. brachytherapy delivering 20 Gy at 5 mm reduced the rate of recurrent keloids resistant to other treatments and gave good functional results. (authors)

  8. Experiences with alanine dosimetry in afterloading brachytherapy

    International Nuclear Information System (INIS)

    Eberhardt, H.-J.; Gohs, U.

    1996-01-01

    At the present, the most commonly used dosimetry for radiotherapy applications are ionisation chambers and thermoluminescent dosimeters (TLD). However, there are some undesirable characteristics of these dosimetry systems, such as large detection volume (ionisation chamber) as well as fading of the radiation induced signal with time and destructive readout (TLG). The present study is an investigation into the use of the alanine/ESR dosimetry in fractionated afterloading brachytherapy during the whole radiotherapy course. There are some qualities which make alanine dosimetry attractive. These are the linear energy response, low fading under standard conditions, and the nondestructive readout. Thus the alanine dosimetry makes possible cumulative dose measurements during the radiotherapy course and an archival storage. By ionizing radiation (gamma, e, n, p, charged particles) free radicals (unpaired electrons) are produced in the amino acid alanine. The continuous wave electron spin resonance (ESR) spectroscopy is used to determine the number of free radicals, which is proportional to the absorbed dose and the alanine content of the dosimeter. The ESR measurements were made at room temperature using a Bruker EPR analyzer EMS-104. The dosimeters used in the test are alanine pellets (23.72 mg weight, 4.9 mm diameter, 1 mm height) as well as flexible alanine film dosimeters (thickness about 500 μm). The dosimeters consist of a blend of L-alpha-alanine and a binder. The alanine content of the pellets and the film dosimeters is about 88 % and 50 % by weight, respectively. The dosimeters for the calculation of the dose-effect-relationship were irradiated at the Physical-Technical Bundesanstalt in Braunschweig by a standard 60Co source. The maximum deviation from the calculated linear function is about 0.12 Gy in the dose range up to 80 Gy. The goal of medical applications was the superficial dose measurement in afterloading brachytherapy during the radiotherapy course in

  9. High dose rate endobronchial brachytherapy - treatment technique

    International Nuclear Information System (INIS)

    Carvalho, Heloisa de Andrade; Aisen, Salim; Haddad, Cecilia Maria Kalil; Nadalin, Wladimir; Pedreira Junior, Wilson Leite; Chavantes, Maria Cristina

    1998-01-01

    High dose rate endobronchial brachytherapy is efficient in symptom relief due to obstructive endobronchial malignancies. However, it's role in survival improvement for patients with lung cancer is not yet established. The use of this treatment in increasing, specially in the developing countries. The purpose of this paper is to present the treatment technique used in the Radiotherapy Department of the Hospital da Clinicas, University of Sao Paulo, based on an experience of 60 cases treated with 180 procedures. Some practical suggestions and rules adopted in the Department are described. The severe complications rate is 6.7%, demonstrating an adequate patient selection associated with the technique utilized. (author)

  10. An afterloading brachytherapy device utilizing thermoplastic material

    International Nuclear Information System (INIS)

    Kim, T.H.; Gerbi, J.B.; Deibel, F.C.; Khan, F.M.; Priest, J.R.

    1989-01-01

    An afterloading brachytherapy device for treatment of residual cancer in an enucleated orbit with two cesium-137 sources was designed using a thermoplastic material, Aquaplast. The device consists of a face-mask support held in place with elastic bands around the head and an acrylic afterloading applicator. The device is very easy to make, holds the sources firmly in place, allows full mobility of the patient, and gives excellent dose distribution to the target area. It was easily tolerated by a 7-year-old child during the 50 h of treatment. (author). 3 refs.; 4 figs

  11. A study of Brachytherapy for Intraocular Tumor

    International Nuclear Information System (INIS)

    Ji, Kwang Soo; Yoo, Dae Hyun; Lee, Sung Goo; Kim, Jae Hu; Ji, Young Hun

    1996-01-01

    The eye enucleation or external-beam radiation therapy that has been commonly used for the treatment of intraocular tumor have demerits of visual loss and in deficiency of effective tumor dose. Recently, brachytherapy using the plaques containing radioisotope-now treatment method that decrease the demerits of the above mentioned treatment methods and increase the treatment effect-is introduced and performed in the countries, Our purpose of this research is to design suitable shape of plaque for the ophthalmic brachytherapy, and to measure absorbed doses of Ir-192 ophthalmic plaque and thereby calculate the exact radiation dose of tumor and it's adjacent normal tissue. In order to brachytherapy for intraocular tumor, 1. to determine the eye model and selected suitable radioisotope 2. to design the suitable shape of plaque 3. to measure transmission factor and dose distribution for custom made plaques 4. to compare with the these data and results of computer dose calculation models. The result were as followed. 1. Eye model was determined as a 25 mm diameter sphere, Ir-192 was considered the most appropriate as radioisotope for brachytherapy, because of the size, half, energy and availability. 2. Considering the biological response with human tissue and protection of exposed dose, we made the plaques with gold, of which size were 15 mm, 17 mm and 20 mm in diameter, and 1.5 mm in thickness. 3. Transmission factor of plaques are all 0.71 with TLD and film dosimetry at the surface of plaques and 0.45, 0.49 at 1.5 mm distance of surface, respectively. 4. As compared the measured data for the plaque with Ir-192 seeds to results of computer dose calculation model by Gary Luxton et al. and CAP-PLAN (Radiation Treatment Planning System), absorbed doses are within ±10% and distance deviations are within 0.4 mm Maximum error is -11.3% and 0.8 mm, respectively. As a result of it, we can treat the intraocular tumor more effectively by using custom made gold plaque and Ir-192

  12. El ajuste estratégico: las relaciones entre la estrategia competitiva, la estrategia de recursos humanos y la estrategia de producción

    OpenAIRE

    González Sánchez, Daniel

    2017-01-01

    [ES] Este trabajo se centra en el estudio del ajuste estratégico que se produce en la empresa entre distintos niveles de estrategia y entre diferentes funciones de la misma. En concreto, analizamos el ajuste entre la estrategia competitiva, la estrategia de recursos humanos y la estrategia de producción, prestando especial atención al área de recursos humanos. Para ello concebimos la estrategia competitiva de acuerdo al paradigma propuesto por Porter (1980), nos basamos en la teoría de la ...

  13. Análisis de los factores de ajuste por utilización de carril en intersecciones semaforizadas de bogotá d. c.

    OpenAIRE

    Peña Lindarte, Ricardo José

    2010-01-01

    Este artículo está basado en el planteamiento metodológico desarrollado en el Manual de Capacidad de Carreteras de Estados Unidos (HCM - Highway Capacity Manual), de la Transportation Research Board (TRB), para el análisis de capacidad y niveles de servicio en intersecciones semaforizadas, asociado al factor de ajuste por utilización de carril (fLU), que corresponde a uno de los once factores de ajuste propuestos en la metodología de cálculo, en el módulo de intensidades de saturación. La est...

  14. Comércio intra-industrial e custos de ajuste para a indústria do Valle del Cauca (1975-2014)

    OpenAIRE

    Hernández García, Edwin Arbey; Universidad del Valle; Raffo López, Leonardo; Universidad del Valle

    2016-01-01

    RESUMEN El objetivo del artículo es analizar los costos de ajuste para la industria vallecaucana durante el período 1975-2014, considerando el patrón de comercio exterior del Departamento. Para ello, se calcula el índice de Brülhart para analizar el comercio intra-industrial marginal. También se examina la naturaleza vertical y horizontal del comercio intra-industrial, y su relación con los costos de ajuste en la industria del Departamento. Como principal resultado, se obtiene que las relacio...

  15. High dose rate brachytherapy for superficial cancer of the esophagus

    International Nuclear Information System (INIS)

    Maingon, Philippe; D'Hombres, Anne; Truc, Gilles; Barillot, Isabelle; Michiels, Christophe; Bedenne, Laurent; Horiot, Jean Claude

    2000-01-01

    Purpose: We analyzed our experience with external radiotherapy, combined modality treatment, or HDR brachytherapy alone to limited esophageal cancers. Methods and Materials: From 1991 to 1996, 25 patients with limited superficial esophagus carcinomas were treated by high dose rate brachytherapy. The mean age was 63 years (43-86 years). Five patients showed superficial local recurrence after external radiotherapy. Eleven patients without invasion of the basal membrane were staged as Tis. Fourteen patients with tumors involving the submucosa without spreading to the muscle were staged as T1. Treatment consisted of HDR brachytherapy alone in 13 patients, external radiotherapy and brachytherapy in 8 cases, and concomitant chemo- and radiotherapy in 4 cases. External beam radiation was administered to a total dose of 50 Gy using 2 Gy daily fractions in 5 weeks. In cases of HDR brachytherapy alone (13 patients), 6 applications were performed once a week. Results: The mean follow-up is 31 months (range 24-96 months). Twelve patients received 2 applications and 13 patients received 6 applications. Twelve patients experienced a failure (48%), 11/12 located in the esophagus, all of them in the treated volume. One patient presented an isolated distant metastasis. In the patients treated for superficial recurrence, 4/5 were locally controlled (80%) by brachytherapy alone. After brachytherapy alone, 8/13 patients were controlled (61%). The mean disease-free survival is 14 months (1-36 months). Overall survival is 76% at 1 year, 37% at 2 years, and 14% at 3 years. Overall survival for Tis patients is 24% vs. 20% for T1 (p 0.83). Overall survival for patients treated by HDR brachytherapy alone is 43%. One patient presented with a fistula with local failure after external radiotherapy and brachytherapy. Four stenosis were registered, two were diagnosed on barium swallowing without symptoms, and two required dilatations. Conclusion: High dose rate brachytherapy permits the treating

  16. RECURSOS PARA A EDUCAÇÃO E LIMITES DO AJUSTE FISCAL

    Directory of Open Access Journals (Sweden)

    Vera Lúcia Ferreira Alves de Brito

    Full Text Available Resumo: Este artigo analisa o financiamento da rede pública estadual de Minas Gerais e a remuneração dos professores da rede entre 2003 e 2014. Focaliza a modernização da administração governamental e os efeitos do programa denominado "Choque de gestão" na aplicação dos recursos para a função educação e para a remuneração do magistério assim como analisa a limitação imposta pela Lei de Responsabilidade Fiscal para os gastos com pessoal. Para isso, foram analisados dados orçamentários e relatórios do Tribunal de Contas do Estado de Minas Gerais. O trabalho é parte da pesquisa "Remuneração de professores da educação básica pública: configurações, impactos, impasses e perspectivas", realizada para o Observatório da Educação. A pesquisa constatou a diminuição de recursos financeiros para a função educação em Minas Gerais e a não implantação do piso salarial profissional nacional para os professores da rede estadual de educação básica.

  17. How to optimize therapeutic ratio in brachytherapy of head and neck squamous cell carcinoma?

    International Nuclear Information System (INIS)

    Mazeron, J.J.; Simon, J.M.; Hardiman, C.; Gerbaulet, A.

    1998-01-01

    Considerable experience has been accumulated with low dose rate (LDR) brachytherapy in the treatment of squamous cell carcinoma of the oral cavity and oropharynx, 4 cm or less in diameter. Recent analysis of large clinical series provided data indicating that modalities of LDR brachytherapy should be optimized in treating these tumours for increasing therapeutic ratio. LDR brachytherapy is now challenged by high dose rate (HDR) brachytherapy and pulsed dose rate (PDR) brachytherapy. Preliminary results obtained with the last two modalities are discussed in comparison with those achieved with LDR brachytherapy. (orig.)

  18. Algoritmos Evolutivos y su empleo en el ajuste de controladores del tipo PID: Estado Actual y Perspectivas

    Directory of Open Access Journals (Sweden)

    Gilberto Reynoso-Meza

    2013-07-01

    Full Text Available Resumen: Los controladores PID continúan siendo una solución fiable, robusta, práctica y sencilla para el control de procesos. Actualmente constituyen la primera capa de control de la gran mayoría de las aplicaciones industriales. De ahí que un número importante de trabajos de investigación se han orientado a mejorar su rendimiento y prestaciones. Las líneas de investigación en este campo van desde nuevos métodos de ajuste, pasando por nuevos tipos de estructura hasta metodologías de diseño integrales. Particularizando en el ajuste de parámetros, una de las formas de obtener una solución novedosa consiste en plantear un problema de optimización, el cual puede llegar a ser no-lineal, no-convexo y con restricciones. Dado que los algoritmos evolutivos han mostrado un buen desempeño para solucionar problemas complejos de optimización, han sido utilizados en diversas propuestas relacionadas con el ajuste de controladores PID. Este trabajo muestra un revisión de estas propuestas y las prestaciones obtenidas en cada caso. Así mismo, se identifican algunas tendencias y posibles líneas de trabajo futuras. Abstract: PID controllers are a reliable, robust, practical and easy to implement control solution for industrial processes. They provide the first control layer for a vast majority of industrial applications. Owing to this, several researches invest time and resources to improve their performance. The research lines in this field scope with new tuning methods, new types of structures and integral design methods. For tuning methods, improvements could be fulfilled stating an optimization problem, which could be non-linear, non-convex and highly constrained. In such instances, evolutionary algorithms have shown a good performance and have been used in various proposals related with PID controllers tuning. This work shows a review of these proposals and the benefits obtained in each case. Some

  19. Ajuste social em pacientes com transtorno afetivo bipolar, unipolar, distimia e depressão dupla Social disability in patients with bipolar and unipolar affective disorders, dysthymia and double depression

    Directory of Open Access Journals (Sweden)

    Adriana M Tucci

    2001-06-01

    Full Text Available OBJETIVOS: Dados internacionais mostram que os transtornos afetivos têm uma prevalência de, aproximadamente, 11,3% da população. Além disso, são uma das doenças que mais geram perdas sociais e nos relacionamentos familiares. O objetivo deste trabalho foi avaliar o ajuste social e familiar de pacientes com transtornos afetivos (bipolar, unipolar, distimia e com depressão dupla, comparando o resultado entre as categorias diagnósticas, além de verificar quais variáveis estão associadas e conduzem ao pior ajuste. MÉTODOS: Foram feitos a caracterização socioeconômica e demográfica e um levantamento dos dados de evolução e de história da doença por meio de um questionário elaborado para essa finalidade. Para a avaliação de ajuste social, utilizou-se a Escala de Avaliação da Incapacitação Psiquiátrica (DAS/OMS, 1998. O relacionamento familiar foi avaliado pelo Global Assessment of Relational Functioning Scale (GARF/APA, 1994. Foram estudados 100 pacientes em tratamento, por pelo menos seis meses, no Ambulatório de Psiquiatria da Faculdade de Medicina Unesp, Botucatu, SP. RESULTADOS/CONCLUSÕES: Com predomínio de mulheres, a maioria dos pacientes tinha no mínimo dois anos de seguimento, idade acima de 50 anos, baixa escolaridade e nível socioeconômico baixo. Não houve diferença estatística significativa quanto aos dados socioeconômicos e demográficos. Na análise de regressão logística, o diagnóstico e o relacionamento familiar tiveram papel significativo no resultado de ajustamento social. Os pacientes unipolares e os distímicos tiveram melhores resultados no ajustamento social e no relacionamento familiar do que os bipolares e aqueles com depressão dupla.OBJECTIVES: International data show that affective disorders have a prevalence of 11.3% in the general population. Besides that, they are responsible for social dysfunctioning and family relationship distress. The aim of this study was to assess social and

  20. Coatings of nanoparticles applied to brachytherapy treatments

    International Nuclear Information System (INIS)

    Gonzalez, Andreza A.D.C.C.; Rostelato, Maria Elisa C.M.; Souza, Carla D.; Rodrigues, Bruna T.; Souza, Daiane C.B.; Zeituni, Carlos A.; Nogueira, Beatriz R.

    2017-01-01

    Brachytherapy is a treatment for cancer in which the radiation is placed close or in contact with the region to be treated saving the surrounding healthy tissues. Nanotechnology is the science that studies the properties of nanometric materials. Nanobrachytherapy in a new field that unites the advantages of brachytherapy with the small size in the nanoparticle, resulting in an even less invasive treatment. In view of the synthesis of the nanoparticles and their use, there is a fundamental role that is made by the coatings, which not only have the function of avoiding the aggregation of particles, but also stabilize and control their functional properties. Among the range of coatings, the most outstanding are polyethylene glycol (PEG) and gum arabica (GA). PEG improves the surface properties of nanoparticles and presents high stability under biomedical conditions. After the synthesis of gold nanoparticles was developed, PEG and gum arabica were successfully incorporated into the surface. In a vial of pyrex, 1 ml of coating agent and 1 ml of nanoparticles was left under gentle shaking for 2 hours. Incorporation was confirmed by DLS and HRTEM. GA requires further study. (author)

  1. Evaluation of resins for use in brachytherapy

    Energy Technology Data Exchange (ETDEWEB)

    Carvalho, Luiz Claudio F.M. Garcia; Ferraz, Wilmar Barbosa; Chrcanovic, Bruno Ramos; Santos, Ana Maria M., E-mail: ferrazw@cdtn.b, E-mail: amms@cdtn.b [Centro de Desenvolvimento da Tecnologia Nuclear (CDTN/CNEN-MG), Belo Horizonte, MG (Brazil)

    2011-07-01

    Brachytherapy is an advanced cancer treatment where radioactive seeds or sources are placed near or directly into the tumor thus reducing the radiation exposure in the surrounding healthy tissues. Prostate cancer can be treated with interstitial brachytherapy in initial stage of the disease in which tiny radioactive seeds with cylindrical geometry are used. Several kinds of seeds have been developed in order to obtain a better dose distribution around them and with a lower cost manufacturing. These seeds consist of an encapsulation, a radionuclide carrier, and X-ray marker. Among the materials that have potential for innovation in the construction of seeds, biocompatible resins appear as an important option. In this paper, we present some characterization results with Fourier transform infrared spectroscopic (FTIR) and ultraviolet-visible spectroscopy (UV-vis) performed on two types of resins in which curing temperatures for each one were varied as also the results of coatings with these resins under titanium substrates. Interactions of these resins in contact with the simulated body fluid were evaluated by atomic force microscopy, scanning electron microscopy, and energy dispersive X-ray spectroscopy. (author)

  2. A study of brachytherapy for intraocular tumor

    International Nuclear Information System (INIS)

    Ji, Yung Hoon; Lee, Dong Han; Ko, Kyung Hwan; Lee, Tae Won; Lee, Sung Koo; Choi, Moon Sik

    1994-12-01

    Our purpose of this study is to perform brachytherapy for intraocular tumor. The result were as followed. 1. Eye model was determined as a 25 mm diameter sphere. Ir-192 was considered the most appropriate as radioisotope for brachytherapy, because of the size, half, energy and availability. 2. Considering the biological response with human tissue and protection of exposed dose, we made the plaques with gold, of which size were 15 mm, 17 mm and 20 mm in diameter, and 1.5 mm in thickness. 3. Transmission factor of plaques are all 0.71 with TLD and film dosimetry at the surface of plaques and 0.45, 0.49 at 1.5 mm distance of surface, respectively. 4. As compared the measured data for the plaque with Ir-192 seeds to results of computer dose calculation model by Gary Luxton et al. and CAP-PLAN (Radiation Treatment Planning System), absorbed doses are within ±10% and distance deviations are within 0.4 mm. Maximum error is -11.3% and 0.8 mm, respectively. 7 figs, 2 tabs, 28 refs. (Author)

  3. Coatings of nanoparticles applied to brachytherapy treatments

    Energy Technology Data Exchange (ETDEWEB)

    Gonzalez, Andreza A.D.C.C.; Rostelato, Maria Elisa C.M.; Souza, Carla D.; Rodrigues, Bruna T.; Souza, Daiane C.B.; Zeituni, Carlos A.; Nogueira, Beatriz R., E-mail: ccg.andreza@gmail.com, E-mail: elisaros@ipen.br [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)

    2017-07-01

    Brachytherapy is a treatment for cancer in which the radiation is placed close or in contact with the region to be treated saving the surrounding healthy tissues. Nanotechnology is the science that studies the properties of nanometric materials. Nanobrachytherapy in a new field that unites the advantages of brachytherapy with the small size in the nanoparticle, resulting in an even less invasive treatment. In view of the synthesis of the nanoparticles and their use, there is a fundamental role that is made by the coatings, which not only have the function of avoiding the aggregation of particles, but also stabilize and control their functional properties. Among the range of coatings, the most outstanding are polyethylene glycol (PEG) and gum arabica (GA). PEG improves the surface properties of nanoparticles and presents high stability under biomedical conditions. After the synthesis of gold nanoparticles was developed, PEG and gum arabica were successfully incorporated into the surface. In a vial of pyrex, 1 ml of coating agent and 1 ml of nanoparticles was left under gentle shaking for 2 hours. Incorporation was confirmed by DLS and HRTEM. GA requires further study. (author)

  4. The Activity Check of Brachytherapy Isotope

    International Nuclear Information System (INIS)

    Kim, Gun Oh; Lee, Byung Koo; Kwon, Young Ho

    2004-01-01

    An isotope Ir-192, which is used in brachytherapy depends on import in whole quantities. There are a few ways for its activity. measurement using Welltype chamber or the way to rely on authentic decay table of manufacturer. In-air dosimetry using Farmer Chamber, etc. In this paper, let me introduce the way using Farmer chamber which is easier and simple. With the Farmer chamber and source calibration jig, take a measurement the activity of an isotope Ir-192 and compare the value with the value from decay table of manufacturer and check the activity of source. The result of measurement, compared the value from decay table, by ±2.1. (which belongs to recommendable value for AAPM ±5% as difference of error range). It is possible to use on clinical medicine. With the increase in use of brachytherapy, the increase of import is essential. And an accurate activity check of source is compulsory. For the activity check of source, it was possible to use Farmer chamber and source calibration jig without additional purchase of Well type chamber.

  5. Radiotherapy and Brachytherapy : Proceedings of the NATO Advanced Study Institute on Physics of Modern Radiotherapy & Brachytherapy

    CERN Document Server

    Lemoigne, Yves

    2009-01-01

    This volume collects a series of lectures presented at the tenth ESI School held at Archamps (FR) in November 2007 and dedicated to radiotherapy and brachytherapy. The lectures focus on the multiple facets of radiotherapy in general, including external radiotherapy (often called teletherapy) as well as internal radiotherapy (called brachytherapy). Radiotherapy strategy and dose management as well as the decisive role of digital imaging in the associated clinical practice are developed in several articles. Grouped under the discipline of Conformal Radiotherapy (CRT), numerous modern techniques, from Multi-Leaf Collimators (MLC) to Intensity Modulated RadioTherapy (IMRT), are explained in detail. The importance of treatment planning based upon patient data from digital imaging (Computed Tomography) is also underlined. Finally, despite the quasi- totality of patients being presently treated with gamma and X-rays, novel powerful tools are emerging using proton and light ions (like carbon ions) beams, bound to bec...

  6. Brachytherapy. High dose rate brachytherapy - Radiation protection: medical sheet ED 4287

    International Nuclear Information System (INIS)

    Celier, D.; Aubert, B.; Vidal, J.P.; Biau, A.; Lahaye, T.; Gauron, C.; Barret, C.; Boisserie, G.; Branchet, E.; Gambini, D.; Gondran, C.; Le Guen, B.; Guerin, C.; Nguyen, S.; Pierrat, N.; Sarrazin, T.; Donnarieix, D.

    2010-02-01

    After having indicated the required authorization to implement brachytherapy techniques, this document presents the various aspects and measures related to radiation protection when performing high-dose-rate brachytherapy treatments. It presents the concerned personnel, describes the operational process, indicates the associated hazards and the risk related to ionizing radiation, and describes how the risk is to be assessed and how exposure levels are to be determined (elements of risk assessment, delimitation of controlled and monitored areas, personnel classification, and choice of the dose monitoring method). It describes the various components of a risk management strategy (risk reduction, technical measures regarding the installation and the personnel, training and information, prevention and medical monitoring). It briefly presents how risk management is to be assessed, and mentions other related risks (biological risk, handling and posture, handling of heavy loads, mental workload, chemical risk)

  7. Brachytherapy. Pulsed dose rate brachytherapy - Radiation protection: medical sheet ED 4250

    International Nuclear Information System (INIS)

    Celier, D.; Aubert, B.; Vidal, J.P.; Biau, A.; Lahaye, T.; Gauron, C.; Barret, C.; Boisserie, G.; Branchet, E.; Gambini, D.; Gondran, C.; Le Guen, B.; Guerin, C.; Nguyen, S.; Pierrat, N.; Sarrazin, T.; Donnarieix, D.

    2009-06-01

    After having indicated the required authorization to implement brachytherapy techniques, this document presents the various aspects and measures related to radiation protection when performing pulsed-dose-rate brachytherapy treatments. It presents the concerned personnel, describes the operational process, indicates the associated hazards and the risk related to ionizing radiation, and describes how the risk is to be assessed and how exposure levels are to be determined (elements of risk assessment, delimitation of controlled and monitored areas, personnel classification, and choice of the dose monitoring method). It describes the various components of a risk management strategy (risk reduction, technical measures regarding the installation and the personnel, training and information, prevention and medical monitoring). It briefly presents how risk management is to be assessed, and mentions other related risks (biological risk, handling and posture, handling of heavy loads, mental workload, chemical risk)

  8. Treatment of the prostate cancer with high dose rate brachytherapy

    International Nuclear Information System (INIS)

    Martinez, Alvaro; Torres Silva, Felipe

    2002-01-01

    The prostate cancer treatment in early stages is controversial. The high dose rate brachytherapy has been used like monotherapy or boost with external beam radiotherapy in advanced disease. This paper describes the technique and the advantages over other modalities

  9. Manual on brachytherapy. Incorporating: Applications guide, procedures guide, basics guide

    International Nuclear Information System (INIS)

    1992-01-01

    In addition to a basic guide to the principles of the production of ionizing radiation and to methods of radiation protection and dosimetry, this booklet includes information about radiation protection procedures for brachytherapy

  10. BRIT manual after loading brachytherapy kit for intracavitary: initial experience

    International Nuclear Information System (INIS)

    Aggarwal, Lalit M.; Mandal, Abhijit; Asthana, Anupam K.; Shahi, Uday P.; Pradhan, Satyajit

    2007-01-01

    Brachytherapy continues to serve as an important and rapidly evolving tool in the management of cancer. Technological developments in the last two decades have dramatic impact on the safe practice of brachytherapy. A wide range of brachytherapy sources and equipment are available for new therapeutic possibilities. However, decision making with regard to new brachytherapy facilities are need based and depend on the patient load, socioeconomic status of the patients, and funds available with the institution. Remote afterloading equipments are fast replacing the Manual After Loading (MAL) systems. However, keeping in view the large number of patients, who can not afford expensive treatment, the utility of manual after loading system which is inexpensive, cannot be ignored

  11. Intra-luminal brachytherapy of bile duct tumors

    International Nuclear Information System (INIS)

    Udaya Kumar Maiya, M.; Bhat, Naresh; Praveen, L.S.

    2000-01-01

    The objective of this study has been to assess the feasibility of intraluminal brachytherapy of the biliary ductal system. The technique of the procedure with its attendant problems and how to overcome the same will be discussed in detail

  12. Les particules illocutoires, variable d’ajustement de la traduction sous-titrante au cinéma

    Directory of Open Access Journals (Sweden)

    Ève Vayssière

    2010-12-01

    Full Text Available Die illokutiven Partikel fungieren als Anpassungsvariable, die beim Übersetzungsakt zur Untertitelung von Filmen entweder weggelassen werden oder erscheinen. Wenn sie einfach gelöscht werden, ergeben sich weder grammatikalische Störungen noch Informationsverlust. Das Auftauchen dieser Partikel in den deutschen Untertiteln zeigt jedoch, wie wichtig sie sind: Als Partikel der Oralität tragen sie zur Idiomatizität bei.Les particules illocutoires sont des variables d’ajustement lors de l’acte de traduction sous-titrante au cinéma, elles peuvent être supprimées sans que cela occasionne de dysfonctionnement grammatical et elles disparaissent lors de la traduction en français sans que cela occasionne une perte d’informations. Leur apparition dans les sous-titres allemands montre néanmoins leur importance : particules de l’oralité, elles sont vecteur d’« idiomaticité ».

  13. American Brachytherapy Society consensus report for accelerated partial breast irradiation using interstitial multicatheter brachytherapy.

    Science.gov (United States)

    Hepel, Jaroslaw T; Arthur, Douglas; Shaitelman, Simona; Polgár, Csaba; Todor, Dorin; Zoberi, Imran; Kamrava, Mitchell; Major, Tibor; Yashar, Catheryn; Wazer, David E

    To develop a consensus report for the quality practice of accelerated partial breast irradiation (APBI) using interstitial multicatheter brachytherapy (IMB). The American Brachytherapy Society Board appointed an expert panel with clinical and research experience with breast brachytherapy to provide guidance for the current practice of IMB. This report is based on a comprehensive literature review with emphasis on randomized data and expertise of the panel. Randomized trials have demonstrated equivalent efficacy of APBI using IMB compared with whole breast irradiation for select patients with early-stage breast cancer. Several techniques for placement of interstitial catheters are described, and importance of three-dimensional planning with appropriate optimization is reviewed. Optimal target definition is outlined. Commonly used dosing schemas include 50 Gy delivered in pulses of 0.6-0.8 Gy/h using pulsed-dose-rate technique and 34 Gy in 10 fractions, 32 Gy in eight fractions, or 30 Gy in seven fractions using high-dose-rate technique. Potential toxicities and strategies for toxicity avoidance are described in detail. Dosimetric constraints include limiting whole breast volume that receives ≥50% of prescription dose to 0.75 (>0.85 preferred), V 150  < 45 cc, and V 200  < 14 cc. Using an optimal implant technique coupled with optimal planning and appropriate dose constraints, a low rate of toxicity and a good-to-excellent cosmetic outcome of ≥90% is expected. IMB is an effective technique to deliver APBI for appropriately selected women with early-stage breast cancer. This consensus report has been created to assist clinicians in the appropriate practice of APBI using IMB. Copyright © 2017 American Brachytherapy Society. Published by Elsevier Inc. All rights reserved.

  14. Resolving the brachytherapy challenges with government funded hospital.

    Science.gov (United States)

    Nikam, D S; Jagtap, A S; Vinothraj, R

    2016-01-01

    The objective of this study is to rationalize the feasibility and cost-effectiveness of high dose rate (HDR) cobalt 60 (Co-60) source versus 192-Iridium (192-Ir) source brachytherapy in government funded hospitals and treatment interruption gap because of exchange of sources. A retrospective study of gynecological cancer patients, treated by radiotherapy with curative intent between April 2005 and September 2012 was conducted. We analyzed the total number of patients treated for external beam radiotherapy (EBRT) and brachytherapy (Intracavitary brachytherapy or cylindrical vaginal source). The dates for 192-Ir sources installation and the last date and first date of brachytherapy procedure before and after source installation respectively were also analyzed and calculated the gap in days for brachytherapy interruptions. The study was analyzed the records of 2005 to September 2012 year where eight 192-Ir sources were installed. The mean gap between treatment interruptions was 123.12 days (range 1-647 days). The Institutional incidence of gynecological cancer where radiotherapy was treatment modality (except ovary) is 34.9 percent. Around 52.25 percent of patients who received EBRT at this institute were referred to outside hospital for brachytherapy because of unavailability of Iridium source. The cost for 5 year duration for single cobalt source is approximately 20-22 lakhs while for 15 Iridium sources is approximately 52-53 lakhs. The combined HDR Co-60 brachytherapy and EBRT provide a useful modality in the treatment of gynecological cancer where radiotherapy is indicated, the treatment interruption because of source exchange is longer and can be minimized by using cobalt source as it is cost-effective and has 5 year working life. Thus, Co-60 source for brachytherapy is a feasible option for government funded hospitals in developing countries.

  15. Review of advanced catheter technologies in radiation oncology brachytherapy procedures

    OpenAIRE

    Zhou J; Zamdborg L; Sebastian E

    2015-01-01

    Jun Zhou,1,2 Leonid Zamdborg,1 Evelyn Sebastian1 1Department of Radiation Oncology, Beaumont Health System, 2Oakland University William Beaumont School of Medicine, Royal Oak, MI, USA Abstract: The development of new catheter and applicator technologies in recent years has significantly improved treatment accuracy, efficiency, and outcomes in brachytherapy. In this paper, we review these advances, focusing on the performance of catheter imaging and reconstruction techniques in brachytherapy ...

  16. High versus low-dose rate brachytherapy for cervical cancer.

    Science.gov (United States)

    Patankar, Sonali S; Tergas, Ana I; Deutsch, Israel; Burke, William M; Hou, June Y; Ananth, Cande V; Huang, Yongmei; Neugut, Alfred I; Hershman, Dawn L; Wright, Jason D

    2015-03-01

    Brachytherapy plays an important role in the treatment of cervical cancer. While small trials have shown comparable survival outcomes between high (HDR) and low-dose rate (LDR) brachytherapy, little data is available in the US. We examined the utilization of HDR brachytherapy and analyzed the impact of type of brachytherapy on survival for cervical cancer. Women with stages IB2-IVA cervical cancer treated with primary (external beam and brachytherapy) radiotherapy between 2003-2011 and recorded in the National Cancer Database (NCDB) were analyzed. Generalized linear mixed models and Cox proportional hazards regression were used to examine predictors of HDR brachytherapy use and the association between HDR use and survival. A total of 10,564 women including 2681 (25.4%) who received LDR and 7883 (74.6%) that received HDR were identified. Use of HDR increased from 50.2% in 2003 to 83.9% in 2011 (Puse of HDR. While patients in the Northeast were more likely to receive HDR therapy, there were no other clinical or socioeconomic characteristics associated with receipt of HDR. In a multivariable Cox model, survival was similar between the HDR and LDR groups (HR=0.93; 95% CI 0.83-1.03). Similar findings were noted in analyses stratified by stage and histology. Kaplan-Meier analyses demonstrated no difference in survival based on type of brachytherapy for stage IIB (P=0.68), IIIB (P=0.17), or IVA (P=0.16) tumors. The use of HDR therapy has increased rapidly. Overall survival is similar for LDR and HDR brachytherapy. Copyright © 2015 Elsevier Inc. All rights reserved.

  17. Image-robot coupling for the prostate brachytherapy

    International Nuclear Information System (INIS)

    Coelen, V.; Lartigau, E.; Merzouki, R.

    2009-01-01

    The results allows to contemplate a robot use in the prostate brachytherapy but equally in other applications such prostate biopsy. The tests to come are going to be directed towards on the use of a prostate phantom in order to calibrate the ultrasonography. thereafter, we contemplate the conception of an intelligent gripping system placed on the robot arm and allowing a good control in closed loop of the brachytherapy needle placement and allowing the setting up of an online monitoring. (N.C.)

  18. MO-B-BRC-01: Introduction [Brachytherapy

    Energy Technology Data Exchange (ETDEWEB)

    Prisciandaro, J. [University of Michigan (United States)

    2016-06-15

    Brachytherapy has proven to be an effective treatment option for prostate cancer. Initially, prostate brachytherapy was delivered through permanently implanted low dose rate (LDR) radioactive sources; however, high dose rate (HDR) temporary brachytherapy for prostate cancer is gaining popularity. Needle insertion during prostate brachytherapy is most commonly performed under ultrasound (U/S) guidance; however, treatment planning may be performed utilizing several imaging modalities either in an intra- or post-operative setting. During intra-operative prostate HDR, the needles are imaged during implantation, and planning may be performed in real time. At present, the most common imaging modality utilized for intra-operative prostate HDR is U/S. Alternatively, in the post-operative setting, following needle implantation, patients may be simulated with computed tomography (CT) or magnetic resonance imaging (MRI). Each imaging modality and workflow provides its share of benefits and limitations. Prostate HDR has been adopted in a number of cancer centers across the nation. In this educational session, we will explore the role of U/S, CT, and MRI in HDR prostate brachytherapy. Example workflows and operational details will be shared, and we will discuss how to establish a prostate HDR program in a clinical setting. Learning Objectives: Review prostate HDR techniques based on the imaging modality Discuss the challenges and pitfalls introduced by the three imagebased options for prostate HDR brachytherapy Review the QA process and learn about the development of clinical workflows for these imaging options at different institutions.

  19. Electronic brachytherapy management of atypical fibroxanthoma: report of 8 lesions

    Directory of Open Access Journals (Sweden)

    Stephen Doggett

    2017-01-01

    Full Text Available Purpose : To evaluate the suitability of treating atypical fibroxanthoma (AFX, an uncommon skin malignancy, with electronic brachytherapy. Material and methods : From Feb 2013 to Sep 2014, we were referred a total of 8 cases of AFX in 7 patients, all involving the scalp. All of them were treated with electronic brachytherapy 50 Kev radiations (Xoft Axxent®, Fremont, California. All lesions received 40 Gy in two fractions per week with 5mm margins. Results : At a median follow-up of 23.7 months, the local recurrence rate is 12.5%. The single lesion that failed was not debulked surgically prior to electronic brachytherapy. Conclusions : To our knowledge, this is the first report in the literature on the use of radiation therapy as curative primary treatment for AFX. No contraindication to the use of radiations is found in the literature, with surgery being the sole treatment for AFX noted. Our recurrence rate is 0% for debulked lesions. Risk of recurrence is mitigated with surgical debulking prior to brachytherapy. Electronic brachytherapy appears to be a safe and effective treatment for debulked AFX. Multiple excisions, skin grafting, and wound care can be avoided in elderly patients by the use of electronic brachytherapy.

  20. Role of brachytherapy in the treatment of localized prostate cancer

    Directory of Open Access Journals (Sweden)

    A. D. Kaprin

    2015-01-01

    Full Text Available The review is devoted to application of brachytherapy for treating the localized prostate cancer (PC. Statistics for incidence and detectability of this pathology and its dynamics for recent years are represented. Brief analysis of other methods which are conveniently used for treatment of PC, such as radical prostatectomy and external-beam radiotherapy, was performed. Advantages and disadvantages of these methods have been discussed. Brief history about the development of brachytherapy from first experience to wide-spread use in clinical practice is reported. The detailed review of series of large trials from Russia and other countries for efficiency and safety of brachytherapy in patients with prostate cancer for recent 15 years is also represented. Two types of brachytherapy in current clinical oncology i.e. low-dose technique with permanent implantation of microsources and high-dose temporary isotope implantation, specifics of its application in different groups of patients have been described. The procedure of brachytherapy and its three main steps i.e. planning, implantation and control assessment after implantation have been characterized in details. The conclusion about benefits of using of brachytherapy in the treatment of prostate cancer as minimally invasive and efficient method was made. 

  1. [Comparison of quality of life of patients treated for SUI by surgical approaches AJUST and TVT-O - a 3-month results from randomized trial].

    Science.gov (United States)

    Smažinka, M; Švabík, K; Hubka, P; Haddad El, R; Mašata, J

    2015-06-01

    The aim of this study is to compare quality of life in 3-month follow-up after the use of transobturator tape TVT-O and single incision tape AJUST in the treatment of urodynamic stress urinary incontinence (USI). Randomized trial. Gynekologicko-porodnická klinika LF UK a FN Plzeň, Gynekologicko-porodnická klinika 1. LF UK a VFN Praha. Between May 2010 and May 2012 100 women with proven urodynamic stress urinary incontinence were included in this randomized trial. These patients were randomly chosen and devided into two group: 50 patients for TVT-O procedure and 50 patients for AJUST procedure. All of the patients underwent a complete urogynecological examination prior to the actual procedure (clinical examination, urodynamic examination, ultrasound examination) and filled in ICIQ-SF and iQol questionnaires. After the surgery, the patients satisfaction was evaluated by visual analoque scale (VAS) and Likert scale and by ICIQ-SF and iQol questionnaires. The intensity and length of postoperative pain was monitored using the visual analogue scale. The patients underwent an examination after 3 months. In both groups of participants no significant differences regarding age, BMI, parity, history of surgery for gynecological disorders, were found. Preoperative urodynamic, ICIQ-SF and iQol parameters were also not significantly different. In the 3-month follow-up 48 participants from TVT-O group and 50 participants from the AJUST group were monitored. No statistically significant differences in subjective and objective parameters were found. Subjectively stress incontinence was not present in 97.9% in the TVT-O and 96.0% in the group AJUST. Objectively stress test was negative in 93.8% in the TVT-O and 94% in group AJUST. By evaluating the ICIQ and iQol were found no statistical differences in the quality of life in both operating groups. At 3-months follow up we did not find any statistical difference between subjective and objective outcome for single incision tape

  2. Overview of brachytherapy resources in Europe: A survey of patterns of care study for brachytherapy in Europe

    International Nuclear Information System (INIS)

    Guedea, Ferran; Ellison, Tracey; Venselaar, Jack; Borras, Josep Maria; Hoskin, Peter; Poetter, Richard; Heeren, Germaine; Nisin, Roselinne; Francois, Guy; Mazeron, Jean Jacques; Limbergen, Erik Van; Ventura, Montserrat; Taillet, Michel; Cottier, Brian

    2007-01-01

    Background and purpose: The Patterns of Care for Brachytherapy in Europe (PCBE) study is aimed at establishing a detailed information system on brachytherapy throughout Europe. Materials and methods: The questionnaire was web-based and the analysis used data from each radiotherapy department with brachytherapy. There were three groups: Group I with 19 countries (15 initial European Community (EC) countries plus Iceland, Monaco, Norway and Switzerland -EC+4-), Group II with 10 countries (New European Community countries -NEC-) and Group III with 14 countries (Other European Countries -OEC-). Results: In the European area there are 36 of 43 countries (85%) which achieved data collection from at least 50% of centres, and were included in the analysis. The tumour site that had the largest number of treated patients was gynaecological tumours. Several variations have been found in the mean number of patients treated per consultant radiation oncologist and physicist; and in the proportion of brachytherapy patients with gynaecology, prostate and breast tumours, by country and by European area. The provided data showed that the average number of brachytherapy patients per centre increased by 10% between 1997 and 2002. Conclusions: A European wide evaluation of brachytherapy practice using a web-based questionnaire is feasible and that there is considerable variation in both patterns of practice and available resources

  3. Venezuela: del ajuste neoliberal a la promesa de “Socialismo del siglo XXI”

    Directory of Open Access Journals (Sweden)

    Luis Miguel Uharte Pozas

    2009-12-01

    Full Text Available El presente artículo, partiendo de un marco conceptual en torno a la democracia, pretende identificar los rasgos fundamentales del proyecto de gobierno que actualmente rige en Venezuela, y que está liderado por el presidente Hugo Chávez. Se analizan los cambios en el sistema político, en el ámbito económico, en el área social, en participación ciudadana, y en política exterior, realizando una comparación con los dos gobiernos precedentes, el de Carlos Andrés Pérez y el de Rafael Caldera.___________________ABSTRACT:The article takes as its starting point the conceptual framework around democracy and attempts to identify the fundamental characteristics of the project of the government currently in power in Venezuela, led by the president Hugo Chávez. It analyses the changes in the political system, in the field of economy, in the social area, in the citizen participation and the foreign policy, making a comparison with two preceding governments, headed by Carlos Andrés Pérez and Rafael Caldera.  

  4. Paddle-based rotating-shield brachytherapy

    Energy Technology Data Exchange (ETDEWEB)

    Liu, Yunlong; Xu, Weiyu [Department of Electrical and Computer Engineering, University of Iowa, 4016 Seamans Center, Iowa City, Iowa 52242 (United States); Flynn, Ryan T.; Kim, Yusung; Bhatia, Sudershan K.; Buatti, John M. [Department of Radiation Oncology, University of Iowa, 200 Hawkins Drive, Iowa City, Iowa 52242 (United States); Dadkhah, Hossein [Department of Biomedical Engineering, University of Iowa, 1402 Seamans Center, Iowa City, Iowa 52242 (United States); Wu, Xiaodong, E-mail: xiaodong-wu@uiowa.edu [Department of Electrical and Computer Engineering, University of Iowa, 4016 Seamans Center, Iowa City, Iowa 52242 and Department of Radiation Oncology, University of Iowa, 200 Hawkins Drive, Iowa City, Iowa 52242 (United States)

    2015-10-15

    Purpose: The authors present a novel paddle-based rotating-shield brachytherapy (P-RSBT) method, whose radiation-attenuating shields are formed with a multileaf collimator (MLC), consisting of retractable paddles, to achieve intensity modulation in high-dose-rate brachytherapy. Methods: Five cervical cancer patients using an intrauterine tandem applicator were considered to assess the potential benefit of the P-RSBT method. The P-RSBT source used was a 50 kV electronic brachytherapy source (Xoft Axxent™). The paddles can be retracted independently to form multiple emission windows around the source for radiation delivery. The MLC was assumed to be rotatable. P-RSBT treatment plans were generated using the asymmetric dose–volume optimization with smoothness control method [Liu et al., Med. Phys. 41(11), 111709 (11pp.) (2014)] with a delivery time constraint, different paddle sizes, and different rotation strides. The number of treatment fractions (fx) was assumed to be five. As brachytherapy is delivered as a boost for cervical cancer, the dose distribution for each case includes the dose from external beam radiotherapy as well, which is 45 Gy in 25 fx. The high-risk clinical target volume (HR-CTV) doses were escalated until the minimum dose to the hottest 2 cm{sup 3} (D{sub 2cm{sup 3}}) of either the rectum, sigmoid colon, or bladder reached their tolerance doses of 75, 75, and 90 Gy{sub 3}, respectively, expressed as equivalent doses in 2 Gy fractions (EQD2 with α/β = 3 Gy). Results: P-RSBT outperformed the two other RSBT delivery techniques, single-shield RSBT (S-RSBT) and dynamic-shield RSBT (D-RSBT), with a properly selected paddle size. If the paddle size was angled at 60°, the average D{sub 90} increases for the delivery plans by P-RSBT on the five cases, compared to S-RSBT, were 2.2, 8.3, 12.6, 11.9, and 9.1 Gy{sub 10}, respectively, with delivery times of 10, 15, 20, 25, and 30 min/fx. The increases in HR-CTV D{sub 90}, compared to D-RSBT, were 16

  5. Interstitial brachytherapy in carcinoma of the penis

    Energy Technology Data Exchange (ETDEWEB)

    Chaudhary, A.J.; Ghosh, S.; Bhalavat, R.L. [Tata Memorial Hospital, Mumbai (India). Dept. of Radiation Oncology; Kulkarni, J.N. [Tata Memorial Hospital, Mumbai (India). Dept. of Surgery; Sequeira, B.V.E. [Tata Memorial Hospital, Mumbai (India). Dept. of Medical Physics

    1999-01-01

    Aim: Keeping in line with the increasing emphasis on organ preservation, we at the Tata Memorial Hospital have evaluated the role of Ir-192 interstitial implant as regards local control, functional and cosmetic outcome in early as well as locally recurrent carcinoma of the distal penis. Patients and Methods: From October 1988 to December 1996, 23 patients with histopathologically proven cancer of the penis were treated with radical radiation therapy using Ir-192 temporary interstitial implant. Our patients were in the age group of 20 to 60 years. The primary lesions were T1 and 7, T2 in 7 and recurrent in 9 patients. Only 7 patients had palpable groin nodes at presentation, all of which were pathologically negative. The median dose of implant was 50 Gy (range 40 to 60 Gy), using the LDR afterloading system and the Paris system of implant rules for dosimetry. Follow-up ranged from 4 to 117 months (median 24 months). Results: At last follow-up 18 of the 23 patients remained locally controlled with implant alone. Three patients failed only locally, 2 locoregionally and 1 only at the groin. Of the 5 patients who failed locally, 4 were successfully salvaged with partial penectomy and remained controlled when last seen. Local control with implant alone at 8 years was 70% by life table analysis. The patients had excellent functional and cosmetic outcome. We did not record any case of skin or softtissue necrosis. Only 2 patients developed meatal stenosis, both of which were treated endoscopically. Conclusion: Our results lead us to interpret that interstitial brachytherapy with Ir-192 offers excellent local control rates with preservation of organ and function. Penectomy can be reserved as a means for effective salvage. (orig.) [Deutsch] Ziel: Das Prinzip des Organerhalts gewinnt in der Onkologie zunehmend an Bedeutung. Ziel dieser Untersuchung war es, die Rolle der interstitiellen Brachytherapie mit Ir-192 zur Behandlung des fruehen und rezidivierten Peniskarzinoms zu

  6. An overview of interstitial brachytherapy and hyperthermia

    International Nuclear Information System (INIS)

    Brandt, B.B.; Harney, J.

    1989-01-01

    Interstitial thermoradiotherapy, an experimental cancer treatment that combines interstitial radiation implants (brachytherapy) and interstitial hyperthermia, is in the early stages of investigation. In accordance with the procedure used in a current national trial protocol, a 60-minute hyperthermia treatment is administered after catheters are placed into the tumor area while the patient is under general anesthesia. This is immediately followed by loading of radioactive Iridium-192 seeds into the catheters for a defined period of time. Once the prescribed radiation dose is delivered, the radioactive sources are removed and a second, 60-minute hyperthermia treatment is administered. Clinical trials with hyperthermia in combination with radiation have increased in recent years. Nurses caring for these patients need to become more knowledgeable about this investigational therapy. This paper provides an overview of the biologic rationale for this therapy, as well as a description of the delivery method and clinical application. Specific related nursing interventions are defined in a nursing protocol.23 references

  7. Epoxy resins used to seal brachytherapy seed

    International Nuclear Information System (INIS)

    Ferreira, Natalia Carolina Camargos; Ferraz, Wilmar Barbosa; Reis, Sergio Carneiro dos; Santos, Ana Maria Matildes dos

    2013-01-01

    Prostate cancer treatment with brachytherapy is recommended for patients with cancer at an early stage. In this treatment, small radioactive seeds are implanted directly in the prostate gland. These seeds are composed at least of one radionuclide carrier and an X-ray marker enclosed within a metallic tube usually sealed by laser process. This process is expensive and, furthermore, it can provoke a partial volatilization of the radionuclide and change the isotropy in dose distribution around the seed. In this paper, we present a new sealing process using epoxy resin. Three kinds of resins were utilized and characterized by scanning electron microscopy (SEM), energy dispersive X ray (EDS) and by differential scanning calorimetry (DSC) after immersion in simulated body fluid (SBF) and in sodium iodine solution (NaI). The sealing process showed excellent potential to replace the sealing laser usually employed. (author)

  8. Human error in remote Afterloading Brachytherapy

    International Nuclear Information System (INIS)

    Quinn, M.L.; Callan, J.; Schoenfeld, I.; Serig, D.

    1994-01-01

    Remote Afterloading Brachytherapy (RAB) is a medical process used in the treatment of cancer. RAB uses a computer-controlled device to remotely insert and remove radioactive sources close to a target (or tumor) in the body. Some RAB problems affecting the radiation dose to the patient have been reported and attributed to human error. To determine the root cause of human error in the RAB system, a human factors team visited 23 RAB treatment sites in the US. The team observed RAB treatment planning and delivery, interviewed RAB personnel, and performed walk-throughs, during which staff demonstrated the procedures and practices used in performing RAB tasks. Factors leading to human error in the RAB system were identified. The impact of those factors on the performance of RAB was then evaluated and prioritized in terms of safety significance. Finally, the project identified and evaluated alternative approaches for resolving the safety significant problems related to human error

  9. Ajuste de metodologia da eletroforese de proteínas para obtenção de fenótipos isoenzimáticos de moranga Adjustment of the methodology of protein electrophoresis to obtain isozymatic phenotypes of pumpkin

    Directory of Open Access Journals (Sweden)

    Antonio Teixeira do Amaral Júnior

    1994-01-01

    Full Text Available Modificações no procedimento eletroforético foram introduzidas para uma satisfatória obtenção de fenótipos isoenzimáticos de moranga (Cucurbita maxima Duchesne. Extratos de folhas definitivas de oito acessos de moranga foram submetidos à análise eletroforética para revelação dos seguintes sistemas: esterase (EST; fosfatase ácida (ACP; transaminase do glutamato oxaloacetato (GOT, desidrogenase do malato (MDH e peroxidase (PO. Os resultados apontaram a ineficiência do tampão extrator utilizado e satisfatória qualidade do gel de amido de milho nas resoluções dos sistemas EST, ACP, GOT e MDH. Para o sistema PO, adequado efeito de peneiramento molecular só foi possível com a utilização do amido hidrolisado de batata (Sigma. Ajustes no tempo de cozimento do gel, manuseio da corrente elétrica, preparo de soluções corantes e tempo de revelação indicaram os melhores protocolos ao pro-cedimento eletroforético.Changes in the electrophoresis procedures were introduced to obtain a better isozymatic phenotypes of pumpkin (Cucurbita maxima Duchesne. Extracts of eight access of pumpkin's leaves were subjected to electrophoresis analysis in order to reveal the following systems: esterase (EST, acid phosphatase (ACP, glutamate oxaloacetate transaminase (GOT, malato dehydrogenase (MDH and peroxidase (PO. The results pointed out the inefficiency of the extractor buffer used, and the satisfactory quality of maize starch gel electrophoresis in the resolution of EST, ACP, GOT and MDH systems. For PO system a better effect of "molecular sieving" was only possible when potato starch gel (Sigma was used. Adjusting the starch cooking time, handling the electric current, preparing the staining solutions and revealing time indicated the best protocol to the electrophoresis process.

  10. Calibration of Photon Sources for Brachytherapy

    Science.gov (United States)

    Rijnders, Alex

    Source calibration has to be considered an essential part of the quality assurance program in a brachytherapy department. Not only it will ensure that the source strength value used for dose calculation agrees within some predetermined limits to the value stated on the source certificate, but also it will ensure traceability to international standards. At present calibration is most often still given in terms of reference air kerma rate, although calibration in terms of absorbed dose to water would be closer to the users interest. It can be expected that in a near future several standard laboratories will be able to offer this latter service, and dosimetry protocols will have to be adapted in this way. In-air measurement using ionization chambers (e.g. a Baldwin—Farmer ionization chamber for 192Ir high dose rate HDR or pulsed dose rate PDR sources) is still considered the method of choice for high energy source calibration, but because of their ease of use and reliability well type chambers are becoming more popular and are nowadays often recommended as the standard equipment. For low energy sources well type chambers are in practice the only equipment available for calibration. Care should be taken that the chamber is calibrated at the standard laboratory for the same source type and model as used in the clinic, and using the same measurement conditions and setup. Several standard laboratories have difficulties to provide these calibration facilities, especially for the low energy seed sources (125I and 103Pd). Should a user not be able to obtain properly calibrated equipment to verify the brachytherapy sources used in his department, then at least for sources that are replaced on a regular basis, a consistency check program should be set up to ensure a minimal level of quality control before these sources are used for patient treatment.

  11. Methods for prostate stabilization during transperineal LDR brachytherapy

    International Nuclear Information System (INIS)

    Podder, Tarun; Yu Yan; Sherman, Jason; Rubens, Deborah; Strang, John; Messing, Edward; Ng, Wan-Sing

    2008-01-01

    In traditional prostate brachytherapy procedures for a low-dose-rate (LDR) radiation seed implant, stabilizing needles are first inserted to provide some rigidity and support to the prostate. Ideally this will provide better seed placement and an overall improved treatment. However, there is much speculation regarding the effectiveness of using regular brachytherapy needles as stabilizers. In this study, we explored the efficacy of two types of needle geometries (regular brachytherapy needle and hooked needle) and several clinically feasible configurations of the stabilization needles. To understand and assess the prostate movement during seed implantation, we collected in vivo data from patients during actual brachytherapy procedures. In vitro experimentation with tissue-equivalent phantoms allowed us to further understand the mechanics behind prostate stabilization. We observed superior stabilization with the hooked needles compared to the regular brachytherapy needles (more than 40% in bilateral parallel needle configuration). Prostate movement was also reduced significantly when regular brachytherapy needles were in an angulated configuration as compared to the parallel configuration (more than 60%). When the hooked needles were angulated for stabilization, further reduction in prostate displacement was observed. In general, for convenience of dosimetric planning and to avoid needle collision, all needles are desired to be in a parallel configuration. In this configuration, hooked needles provide improved stabilization of the prostate. On the other hand, both regular and hooked needles appear to be equally effective in reducing prostate movement when they are in angulated configurations, which will be useful in seed implantation using a robotic system. We have developed nonlinear spring-damper model for the prostate movement which can be used for adapting dosimetric planning during brachytherapy as well as for developing more realistic haptic devices and

  12. National audit of a system for rectal contact brachytherapy

    Directory of Open Access Journals (Sweden)

    Laia Humbert-Vidan

    2017-01-01

    Full Text Available Background and purpose: Contact brachytherapy is used for the treatment of early rectal cancer. An overview of the current status of quality assurance of the rectal contact brachytherapy systems in the UK, based on a national audit, was undertaken in order to assist users in optimising their own practices. Material and methods: Four UK centres using the Papillon 50 contact brachytherapy system were audited. Measurements included beam quality, output and radiation field size and uniformity. Test frequencies and tolerances were reviewed and compared to both existing recommendations and published reviews on other kV and electronic brachytherapy systems. External validation of dosimetric measurements was provided by the National Physical Laboratory. Results: The maximum host/audit discrepancy in beam quality determination was 6.5%; this resulted in absorbed dose variations of 0.2%. The host/audit agreement in absorbed dose determination was within 2.2%. The median of the radiation field uniformity measurements was 2.7% and the host/audit agreement in field size was within 1 mm. Test tolerances and frequencies were within the national recommendations for kV units. Conclusions: The dosimetric characterisation of the Papillon 50 was validated by the audit measurements for all participating centres, thus providing reassurance that the implementation had been performed within the standards stated in previously published audit work and recommendations for kV and electronic brachytherapy units. However, optimised and standardised quality assurance testing could be achieved by reducing some methodological differences observed. Keywords: Contact brachytherapy, Electronic brachytherapy, Audit

  13. Methods for prostate stabilization during transperineal LDR brachytherapy.

    Science.gov (United States)

    Podder, Tarun; Sherman, Jason; Rubens, Deborah; Messing, Edward; Strang, John; Ng, Wan-Sing; Yu, Yan

    2008-03-21

    In traditional prostate brachytherapy procedures for a low-dose-rate (LDR) radiation seed implant, stabilizing needles are first inserted to provide some rigidity and support to the prostate. Ideally this will provide better seed placement and an overall improved treatment. However, there is much speculation regarding the effectiveness of using regular brachytherapy needles as stabilizers. In this study, we explored the efficacy of two types of needle geometries (regular brachytherapy needle and hooked needle) and several clinically feasible configurations of the stabilization needles. To understand and assess the prostate movement during seed implantation, we collected in vivo data from patients during actual brachytherapy procedures. In vitro experimentation with tissue-equivalent phantoms allowed us to further understand the mechanics behind prostate stabilization. We observed superior stabilization with the hooked needles compared to the regular brachytherapy needles (more than 40% in bilateral parallel needle configuration). Prostate movement was also reduced significantly when regular brachytherapy needles were in an angulated configuration as compared to the parallel configuration (more than 60%). When the hooked needles were angulated for stabilization, further reduction in prostate displacement was observed. In general, for convenience of dosimetric planning and to avoid needle collision, all needles are desired to be in a parallel configuration. In this configuration, hooked needles provide improved stabilization of the prostate. On the other hand, both regular and hooked needles appear to be equally effective in reducing prostate movement when they are in angulated configurations, which will be useful in seed implantation using a robotic system. We have developed nonlinear spring-damper model for the prostate movement which can be used for adapting dosimetric planning during brachytherapy as well as for developing more realistic haptic devices and

  14. Ajustement de la courbe de lactation de la chèvre locale dans les zones arides Tunisiennes

    Directory of Open Access Journals (Sweden)

    Ilyes Mekki

    2011-10-01

    Full Text Available Les performances laitières de la chèvre locale dans les zones arides tunisiennes dépendent des capacités génétiques de l’effet des conditions du milieu et du mode de conduite des troupeaux. L’objectif de cette étude est d’analyser les performances laitières de la chèvre locale en fonction de ces facteurs à travers l’ajustement de la courbe de lactation. De telles connaissances sont indispensables pour planifier la gestion raisonnable de cette ressource animale rustique dans des conditions naturelles difficiles. Les données utilisées pour cette étude sont issues de 10 campagnes de contrôle laitier réalisé au niveau d’un troupeau caprin expérimental conduit dans les régions arides. Suite à l’élaboration des données, l’application des procédures de régression non linéaire a identifié le modèle de Wood comme le plus adaptée pour l’ajustement de la courbe de lactation de la chèvre locale. Ce modèle a été appliqué pour estimer les paramètres de la lactation individuelle et l’étude des facteurs de variation. Les résultats d’ajustements des données montrent que la lactation de la chèvre locale évolue après la mise bas selon une trajectoire assez aplatie. Les performances de la chèvre locale sont assez réduites et similaires à celles observées pour des populations élevées dans des zones difficiles tunisiennes de point de vue climatique et pastorale. La moyenne de production initiale observée est de 720 g/j, le pic de lactation est observé au 17ème jour lorsqu’une chèvre produit en moyenne 980g/j. La réduction des potentialités laitières de la chèvre locale illustre les effets du processus de sélection naturelle qui a favorisé l’adaptation aux conditions difficiles des régions arides. Les résultats contribuent à la caractérisation de la chèvre locale et à la planification de son amélioration comme étant une ressource génétique locale et rustique.

  15. Efectividad del ajuste oclusal en pacientes de alta de ortodoncia Effectiveness of occlusal adjustment in patients with orthodontic discharge

    Directory of Open Access Journals (Sweden)

    Amitis Ruiseco Palomares

    2006-12-01

    Full Text Available El tratamiento ortodóncico tiene como objetivo llegar a un punto óptimo oclusal, estético y funcional. Con frecuencia son introducidas interferencias que a largo plazo pueden provocar disturbios del sistema estomatognático; una técnica de ajuste oclusal puede ser útil para estabilizar la función y garantizar la salud de este. Se seleccionó una muestra constituida por 14 pacientes con más de 6 meses de alta ortodóncica, diagnosticados con interferencias oclusales en una investigación previa. A cada uno de ellos se les realizó un ajuste oclusal por tallado selectivo, y pasados 6 meses, se procedió a la evaluación de la oclusión para la detección de posibles interferencias, analizándolas durante los diferentes movimientos mandibulares, tanto en las áreas de trabajo como de no trabajo, así como por grupos dentarios. Para ello se les realizó el análisis funcional de la oclusión en boca, completándose el estudio con el montaje de los modelos en el articulador semiajustable Dentatus ARL mediante el uso del arco facial. El estudio reveló que a la mayoría de los pacientes se les reestableció una oclusión funcional, lo que demuestra la efectividad del tratamiento, que el mayor porcentaje de interferencias después del ajuste fueron en el área de no trabajo y durante los movimientos de lateralidad, además de que el grupo molar fue el de mayor cantidad de interferencias, tanto antes como después del tratamiento oclusal.The orthodontic treatment is aimed at reaching an occlusal, aesthetic, and functional optimal point. The frequently introduced interferences may cause disorders of the stomathognatic system, and an occlusal adjustment technique may be useful to stabilize the function and to gurantee its health. A sample of 14 patients with more than 6 months of orthodontic discharge that were diagnosed occlusal interferences in a previous research was selected. Each of them underwent occlusal adjustment by selective grinding, and

  16. The American brachytherapy society survey of brachytherapy practice for carcinoma of the cervix in the United States.

    Science.gov (United States)

    Nag, S; Orton, C; Young, D; Erickson, B

    1999-04-01

    The purpose of this study was to survey the brachytherapy practice for cervical cancer in the United States. The Clinical Research Committee of the American Brachytherapy Society (ABS) performed a retrospective survey of individual physicians of the ABS and American Society of Therapeutic Radiologists and Oncologists regarding the details of the brachytherapy techniques they personally used in the treatment of cervical cancer patients for the year 1995. The replies (some of which may have been an estimate only) were tabulated. The scope of this survey did not allow us to verify the data by chart audits. A total of about 3500 questionnaires were mailed out; 521 responses were received. Of these responders, 206 (40%) did not perform any brachytherapy for carcinoma of the cervix in 1995. Of the other 315 responders reporting a total of 4892 patients treated in 1995, 88% used low dose rate (LDR) while 24% used high dose rate (HDR). There was a wide variation in the doses used. For LDR treatments, the median total external beam radiation therapy (EBRT) dose was 45 and 50 Gy and the LDR dose was 42 and 45 Gy for early and advanced cancers, respectively. For HDR treatments, the median EBRT dose was 48 and 50 Gy and the median HDR dose was 29 and 30 Gy for early and advanced cancers, respectively. The median dose per fraction was 6 Gy for a median of five fractions. Interstitial brachytherapy was used as a component of the treatment in 6% of the patients by 21% of responders. Very few responders treated with pulsed or medium dose rates. This retrospective survey showed the current brachytherapy practice pattern in the treatment of cervical cancer in the United States and can serve as a basis for future prospective national brachytherapy data registry. There was wide variation in the practice pattern, emphasizing the urgent need for consensus on these issues. Copyright 1999 Academic Press.

  17. Utilization and Outcomes of Breast Brachytherapy in Younger Women

    International Nuclear Information System (INIS)

    Smith, Grace L.; Huo, Jinhai; Giordano, Sharon H.; Hunt, Kelly K.; Buchholz, Thomas A.; Smith, Benjamin D.

    2015-01-01

    Purpose: To directly compare (1) radiation treatment utilization patterns; (2) risks of subsequent mastectomy; and (3) costs of radiation treatment in patients treated with brachytherapy versus whole-breast irradiation (WBI), in a national, contemporary cohort of women with incident breast cancer, aged 64 years and younger. Methods and Materials: Using MarketScan health care claims data, we identified 45,884 invasive breast cancer patients (aged 18-64 years), treated from 2003 to 2010 with lumpectomy, followed by brachytherapy (n=3134) or whole-breast irradiation (n=42,750). We stratified patients into risk groups according to age (Age<50 vs Age≥50) and endocrine therapy status (Endocrine− vs Endocrine+). “Endocrine+” patients filled an endocrine therapy prescription within 1 year after lumpectomy. Pathologic hormone receptor status was not available in this dataset. In brachytherapy versus WBI patients, utilization trends and 5-year subsequent mastectomy risks were compared. Stratified, adjusted subsequent mastectomy risks were calculated using proportional hazards regression. Results: Brachytherapy utilization increased from 2003 to 2010: in patients Age<50, from 0.6% to 4.9%; patients Age≥50 from 2.2% to 11.3%; Endocrine− patients, 1.3% to 9.4%; Endocrine+ patients, 1.9% to 9.7%. Age influenced treatment selection more than endocrine status: 17% of brachytherapy patients were Age<50 versus 32% of WBI patients (P<.001); whereas 41% of brachytherapy patients were Endocrine–versus 44% of WBI patients (P=.003). Highest absolute 5-year subsequent mastectomy risks occurred in Endocrine−/Age<50 patients (24.4% after brachytherapy vs 9.0% after WBI (hazard ratio [HR] 2.18, 95% confidence interval [CI] 1.37-3.47); intermediate risks in Endocrine−/Age≥50 patients (8.6% vs 4.9%; HR 1.76, 95% CI 1.26-2.46); and lowest risks in Endocrine+ patients of any age: Endocrine+/Age<50 (5.5% vs 4.5%; HR 1.18, 95% CI 0.61-2.31); Endocrine+/Age≥50 (4.2% vs 2

  18. Utilization and Outcomes of Breast Brachytherapy in Younger Women

    Energy Technology Data Exchange (ETDEWEB)

    Smith, Grace L. [Department of Radiation Oncology, The University of Texas MD Anderson Cancer Center, Houston, Texas (United States); Department of Health Services Research, The University of Texas MD Anderson Cancer Center, Houston, Texas (United States); Huo, Jinhai [Department of Health Services Research, The University of Texas MD Anderson Cancer Center, Houston, Texas (United States); Giordano, Sharon H. [Department of Health Services Research, The University of Texas MD Anderson Cancer Center, Houston, Texas (United States); Department of Breast Medical Oncology, The University of Texas MD Anderson Cancer Center, Houston, Texas (United States); Hunt, Kelly K. [Department of Surgical Oncology, The University of Texas MD Anderson Cancer Center, Houston, Texas (United States); Buchholz, Thomas A. [Department of Radiation Oncology, The University of Texas MD Anderson Cancer Center, Houston, Texas (United States); Smith, Benjamin D., E-mail: bsmith3@mdanderson.org [Department of Radiation Oncology, The University of Texas MD Anderson Cancer Center, Houston, Texas (United States); Department of Health Services Research, The University of Texas MD Anderson Cancer Center, Houston, Texas (United States)

    2015-09-01

    Purpose: To directly compare (1) radiation treatment utilization patterns; (2) risks of subsequent mastectomy; and (3) costs of radiation treatment in patients treated with brachytherapy versus whole-breast irradiation (WBI), in a national, contemporary cohort of women with incident breast cancer, aged 64 years and younger. Methods and Materials: Using MarketScan health care claims data, we identified 45,884 invasive breast cancer patients (aged 18-64 years), treated from 2003 to 2010 with lumpectomy, followed by brachytherapy (n=3134) or whole-breast irradiation (n=42,750). We stratified patients into risk groups according to age (Age<50 vs Age≥50) and endocrine therapy status (Endocrine− vs Endocrine+). “Endocrine+” patients filled an endocrine therapy prescription within 1 year after lumpectomy. Pathologic hormone receptor status was not available in this dataset. In brachytherapy versus WBI patients, utilization trends and 5-year subsequent mastectomy risks were compared. Stratified, adjusted subsequent mastectomy risks were calculated using proportional hazards regression. Results: Brachytherapy utilization increased from 2003 to 2010: in patients Age<50, from 0.6% to 4.9%; patients Age≥50 from 2.2% to 11.3%; Endocrine− patients, 1.3% to 9.4%; Endocrine+ patients, 1.9% to 9.7%. Age influenced treatment selection more than endocrine status: 17% of brachytherapy patients were Age<50 versus 32% of WBI patients (P<.001); whereas 41% of brachytherapy patients were Endocrine–versus 44% of WBI patients (P=.003). Highest absolute 5-year subsequent mastectomy risks occurred in Endocrine−/Age<50 patients (24.4% after brachytherapy vs 9.0% after WBI (hazard ratio [HR] 2.18, 95% confidence interval [CI] 1.37-3.47); intermediate risks in Endocrine−/Age≥50 patients (8.6% vs 4.9%; HR 1.76, 95% CI 1.26-2.46); and lowest risks in Endocrine+ patients of any age: Endocrine+/Age<50 (5.5% vs 4.5%; HR 1.18, 95% CI 0.61-2.31); Endocrine+/Age≥50 (4.2% vs 2

  19. Construction balance analysis of dose rate medium brachytherapy TDS

    International Nuclear Information System (INIS)

    Sandi Parapak

    2011-01-01

    One of the most important part of brachytherapy instrument design activities is analyze by determining the centroid point of construction in order to maintain the balance of brachytherapy instrument, either during operation as well as when transported. Operation of brachytherapy is not only done in one place so it is necessary to balance the analysis of the forces at the time did not move, moved on the horizontal floor and sloping floor. Calculation approach who is done to calculate the weight of mechanical components on each module, and then calculate the centroid of each module, for the balance of forces analysis performed with the assumption at the time of brachytherapy in the position of not moving on a horizontal floor, moved from a place to another on the horizontal floor and on the floor with sloping angle 30°. Base on the results of this analysis are expected to balance the four wheels can move without slipping at the time of decline or incline. Also, results of analysis can be used in designing a mobile construction brachytherapy taking into consideration the aesthetic ideal, easy to operate, ensure the safety of equipment, operator and patient. (author)

  20. High dose rate brachytherapy for the palliation of malignant dysphagia

    International Nuclear Information System (INIS)

    Homs, Marjolein Y.V.; Eijkenboom, Wilhelmina M.H.; Coen, Veronique L.M.A.; Haringsma, Jelle; Blankenstein, Mark van; Kuipers, Ernst J.; Siersema, Peter D.

    2003-01-01

    Background and purpose: High dose rate (HDR) brachytherapy is a commonly used palliative treatment for esophageal carcinoma. We evaluated the outcome of HDR brachytherapy in patients with malignant dysphagia. Material and methods: A retrospective analysis over a 10-year period was performed of 149 patients treated with HDR brachytherapy, administered in one or two sessions, at a median dose of 15 Gy. Patients were evaluated for functional outcome, complications, recurrent dysphagia, and survival. Results: At 6 weeks after HDR brachytherapy, dysphagia scores had improved from a median of 3 to 2 (n=104; P<0.001), however, dysphagia had not improved in 51 (49%) patients. Procedure-related complications occurred in seven (5%) patients. Late complications, including fistula formation or bleeding, occurred in 11 (7%) patients. Twelve (8%) patients experienced minor retrosternal pain. Median survival of the patients was 160 days with a 1-year survival rate of 15%. Procedure-related mortality was 2%. At follow-up, 55 (37%) patients experienced recurrent dysphagia. In 34 (23%) patients a metal stent was placed to relieve persistent or recurrent dysphagia. Conclusion: HDR brachytherapy is a moderately effective treatment for the palliation of malignant dysphagia. The incidence of early major complications is low, however, persistent and recurrent dysphagia occur frequently, and require often additional treatment

  1. Brachytherapy - not pulsed and low rate brachytherapy. Medical radiation protection - ED 4248

    International Nuclear Information System (INIS)

    2008-06-01

    After an indication of authorizations required to perform brachytherapy, this sheet indicates the concerned personnel, indicates the different treatment steps, briefly describes the risk related to ionizing radiations, indicates the various aspects of risk assessment and of determination of exposure levels (definition of controlled and monitored areas, personnel classification, possible methods for dose monitoring), presents the strategy for risk management (rules regarding risk reduction, technical measures regarding the installation, individual technical measures, training and information, prevention and medical monitoring) and how this risk management can be assessed

  2. A survey of current clinical practice in permanent and temporary prostate brachytherapy: 2010 update.

    Science.gov (United States)

    Buyyounouski, Mark K; Davis, Brian J; Prestidge, Bradley R; Shanahan, Thomas G; Stock, Richard G; Grimm, Peter D; Demanes, D Jeffrey; Zaider, Marco; Horwitz, Eric M

    2012-01-01

    To help establish patterns of care and standards of care of interstitial permanent low-dose-rate (LDR) and temporary high-dose-rate brachytherapy for prostate cancer and to compare the results with a similar 1998 American Brachytherapy Society (ABS) survey. A comprehensive questionnaire intended to survey specific details of current clinical brachytherapy practice was provided to the participants of the seventh ABS Prostate Brachytherapy School. Responses were tabulated and descriptive statistics are reported. Sixty-five brachytherapy practitioners responded to the survey. Eighty-nine percent (89%) of respondents performed LDR and 49% perform high-dose-rate brachytherapy. The median number of years of experience for LDR brachytherapists increased from 5 to 10 years over the course of the 12 years since the preceding survey. Compared with the first ABS, a smaller proportion of respondents received formal brachytherapy residency training (43% vs. 56%) or formal "hands-on" brachytherapy training (15% vs. 63%). There has been a marked decline in the utilization of the Mick applicator (Mick Radio-Nuclear Instruments, Inc., Mount Vernon, NY, USA) (60% vs. 28%) and an increase in the use of stranded seeds (40% vs. 11%). Compliance with postimplant dosimetry was higher in the 2010 survey. This survey does suggest an evolution in the practice of LDR brachytherapy since 1998 and aids in identifying aspects that require further progress or investigation. ABS guidelines and other practice recommendations appear to impact the practice of brachytherapy. Copyright © 2012 American Brachytherapy Society. Published by Elsevier Inc. All rights reserved.

  3. Radiological protection of patients in brachytherapy

    International Nuclear Information System (INIS)

    Sacc, Ricardo; Herrero, Flavia

    2008-01-01

    Full text: The prefix 'brachy' means short-range, so brachytherapy is the administration of radiation therapy using small radioactive sources in the form of needles, tubes, wires or seeds, which are placed within the tumor -interstitial form- or very near of it, superficially or in an endo-cavity form. This technique, which was limited by the size of the primary tumor, has the advantage, that the radiation, can be adjusted to the size and shape of the tumor volume and the radioisotope used, - short range -, is selected with the criteria of getting the dose in the organs at risk, as low as possible, making what it is known as conformal radiotherapy. Radioactive sources may be permanent or temporary implants. The application of radioactive material, can be manually or automatically. In the first case, a major breakthrough from the radioprotection point of view, was the use of afterloading devices, methodology highly recommended to reduce the radiation exposure to staff. With the development of technology, remotely controlled afterloading devices were introduced, which in addition to complying with the above requirement, allow the source to move in different positions along catheters housed in one or more channels, making therapeutic brachytherapy treatments in tumor volumes possible, that due to its length, decades ago would have been an unthinkable deal. In all cases, sources, which may vary from the 3 mm in length, 125 Iodine or 198 Gold seeds, to extensive wires of 192 Iridium, are encapsulated for two main purposes: preventing leakage of radioactive material and absorption of unwanted radiation, alpha and beta, produced by the radioactive decay. Consequently, it should be highly unlikely that the radioactive material, could be lost or located in the patient, in a different place of the one that was planned. However, history shows us the opposite. Its is known the kind of deterministic effect that radiation is going to produce in the tumor, where the severity of

  4. Standardization of prostate brachytherapy treatment plans

    International Nuclear Information System (INIS)

    Ove, Roger; Wallner, Kent; Badiozamani, Kas; Korjsseon, Tammy; Sutlief, Steven

    2001-01-01

    Purpose: Whereas custom-designed plans are the norm for prostate brachytherapy, the relationship between linear prostate dimensions and volume calls into question the routine need for customized treatment planning. With the goal of streamlining the treatment-planning process, we have compared the treatment margins (TMs) achieved with one standard plan applied to patients with a wide range of prostate volumes. Methods and Materials: Preimplant transrectal ultrasound (TRUS) images of 50 unselected University of Washington patients with T1-T2 cancer and a prostate volume between 20 cc and 50 cc were studied. Patients were arbitrarily grouped into categories of 20-30 cc, 30-40 cc, and 40-50 cc. A standard 19-needle plan was devised for patients in the 30- to 40-cc range, using an arbitrary minimum margin of 5 mm around the gross tumor volume (GTV), making use of inverse planning technology to achieve 100% coverage of the target volume with accentuation of dose at the periphery and sparing of the central region. The idealized plan was applied to each patient's TRUS study. The distances (TMs) between the prostatic edge (GTV) and treated volume (TV) were determined perpendicular to the prostatic margin. Results: Averaged over the entire patient group, the ratio of thickness to width was 1.4, whereas the ratio of length to width was 1.3. These values were fairly constant over the range of volumes, emphasizing that the prostate retains its general shape as volume increases. The idealized standard plan was overlaid on the ultrasound images of the 17 patients in the 30- to 40-cc group and the V100, the percentage of target volume receiving 100% or more of the prescription dose, was 98% or greater for 15 of the 17 patients. The lateral and posterior TMs fell within a narrow range, most being within 2 mm of the idealized 5-mm TM. To estimate whether a 10-cc volume-interval stratification was reasonable, the standard plan generated from the 30- to 40-cc prostate model was

  5. La norma L1 como alternativa a la norma L2 en el ajuste de la regresión

    Directory of Open Access Journals (Sweden)

    Carlos N. Bouza

    2002-01-01

    Full Text Available En este trabajo analizamos el desarrollo y los conceptos de las normas L1 y L2 y se comparan con algunos ejemplos. Por una parte la norma L1 es óptima bajo los supuestos de que los errores tienen la distribución de Laplace. Esta fue propuesta mucho antes que el MC, pero las facilidades de cómputo de éstos últimos le dieron primacía. Actualmente va adquiriendo gran importancia para las aplicaciones económicas, dado que en general los problemas de finanzas y de series temporales incumplen con las hipótesis usadas en el teorema de Gauss-Markoff. El uso de la norma L2, es el método de universal aceptación en el ajuste de la regresión. Sin embargo su optimalidad solo es válida bajo una serie de supuestos que no se cumplen en general (Teorema de Gaus- Markoff. Por lo tanto, norma L1 aparece como una alternativa mejor que la L2 en muchas aplicaciones dada su robustez ante las observaciones atípicas.

  6. EL AJUSTE CONDUCTUAL, EMOCIONAL Y SOCIAL EN HERMANOS DE NIÑOS CON UN TRASTORNO DEL ESPECTRO AUTISTA. UNA REVISIÓN TEÓRICA

    Directory of Open Access Journals (Sweden)

    Raquel Ruiz Aparicio

    2015-09-01

    Full Text Available Las personas con Trastorno del Espectro Autista (TEA tienen características únicas y hay una falta de conocimiento sobre cómo estas características podrían influir en sus familias y en el ajuste conductual, emocional y social de sus hermanos. El presente estudio tiene el objetivo de centrarse en los hermanos de estas personas con TEA y realizar una revisión teórica relacionada con el ajuste conductual, emocional y social de hermanos de niños con TEA. Un total de 24 artículos han sido incluidos y analizados con el fin de encontrar resultados relevantes que puedan ayudar a entender las necesidades de estos hermanos. El estudio sugiere, en ocasiones, resultados diferentes pero identifica aquellos factores de riesgo que podrían impactar en el núcleo familiar y, principalmente, en los hermanos de niños con TEA.

  7. Estableciendo nexos entre Políticas de Ajuste Estructural y su impacto ambiental: una discusión metodológica

    Directory of Open Access Journals (Sweden)

    Rosalba Ortiz

    2011-09-01

    Full Text Available Las políticas de Ajuste Estructural han sido la base de la política económica costarricense en los últimos 10 años, por lo cual, han tenido gran incidencia en el análisis de los procesos y relaciones de cualquier sector productivo. En este contexto, los efectos ambientales de los últimos años, están decididamente influenciados por estas políticas, pues aunque, los programas de Ajuste no tienen como propósito direccionar aspectos ambientales, al modificar algunos precios relativos, pueden propiciar un cambio en el patrón de uso de un recurso, y es así como, tienen un efecto directo o indirecto sobre el ambiente

  8. Breast conserving treatment of locally advanced carcinoma T2 and T3 after neoadjuvant chemotherapy followed by quadrantectomy and high dose-rate brachytherapy, as a boost, complementary teletherapy and adjuvant chemotherapy; Tratamento conservador dos carcinomas de mama localmente avancados T2 e T3, apos quimioterapia neoadjuvante, com quadrantectomia e braquiterapia de alta taxa de dose como reforco de dose, teleterapia complementar e quimioterapia adjuvante

    Energy Technology Data Exchange (ETDEWEB)

    Fristachi, Carlos Elias [Instituto do Cancer Dr. Arnaldo Vieira de Carvalho (ICAVC), Sao Paulo, SP (Brazil). Servico de Onco-Ginecologia e Mastologia]. E-mail: cefristachi@uol.com.br; Miziara Filho, Miguel Abrao; Soares, Celia Regina; Fogaroli, Ricardo Cesar; Pelosi, Edilson Lopes; Martins, Homero Lavieri Martins [Instituto do Cancer Dr. Arnaldo Vieira de Carvalho (ICAVC), Sao Paulo, SP (Brazil). Servico de Radioterapia; Baracat, Fausto Farah [Hospital do Servidor Publico Estadual de Sao Paulo (HSPE), SP (Brazil). Servico de Ginecologia e Mastologia; Piato, Sebastiao [Irmandade da Santa Casa de Misericordia de Sao Paulo, SP (Brazil). Dept. de Obstetricia e Ginecologia (DOGI)

    2005-07-01

    Objective: to assess the treatment of breast cancer T2 and T3(T > = 4 cm), through neoadjuvant chemotherapy, quadrantectomy and high-dose-rate (HDR) brachytherapy as a boost, complementary radiotherapy and adjuvant chemotherapy, considering its method problems, its esthetics results, the aspect of local control, overall survival, and disease-free survival. Patients and method: this clinical prospective descriptive study was based on the evaluation of 26 patients ranging from 30 to 70 years old, with infiltrating ductal carcinoma, clinical stage IIB and IIIA, responsive to the neoadjuvant chemotherapy. Early and late radiotherapy complications were evaluated according to the criteria established by the RTOG/EORTC (Radiotherapy and Oncology Group /European Organization for Research and Treatment of Cancer) groups. Esthetics evaluation was done in accordance with the criteria set by a plastic surgeon. Local control was evaluated by clinical method, mammography and ultrasonography. Overall survival (OS) and the disease-free survival (DFS) were assessed according to Kaplan-Meier methodology. All the patients were treated at the Dr. Arnaldo Vieira de Carvalho Cancer Institute, from June/1995 to November/2001, and evaluated in March, 2002, with median follow-up of 28.7 months. Results: early complications were observed in 8 patients (30.6%). Two patients were classified as G3 and G4 (RTOG/EORTC). Six patients had late complications and three of them (11.5%) were classified as G3 and G4. One patient (3.8%) had local recurrence, 64 months after having local treatment. Esthetics results were considered good or regular in 16 patients (60.5%) out of 24 patients who were examined. Overall survival and disease-free survival in 24, 36 and 60 months were 100%, 92.3% and 83.1% respectively. Conclusion: early and late radiotherapy complications were considerate high when compared to literature, but esthetic results were considered acceptable. RL, OS and DFS were comparable to other

  9. Calculated and measured brachytherapy dosimetry parameters in water for the Xoft Axxent X-Ray Source: an electronic brachytherapy source.

    Science.gov (United States)

    Rivard, Mark J; Davis, Stephen D; DeWerd, Larry A; Rusch, Thomas W; Axelrod, Steve

    2006-11-01

    A new x-ray source, the model S700 Axxent X-Ray Source (Source), has been developed by Xoft Inc. for electronic brachytherapy. Unlike brachytherapy sources containing radionuclides, this Source may be turned on and off at will and may be operated at variable currents and voltages to change the dose rate and penetration properties. The in-water dosimetry parameters for this electronic brachytherapy source have been determined from measurements and calculations at 40, 45, and 50 kV settings. Monte Carlo simulations of radiation transport utilized the MCNP5 code and the EPDL97-based mcplib04 cross-section library. Inter-tube consistency was assessed for 20 different Sources, measured with a PTW 34013 ionization chamber. As the Source is intended to be used for a maximum of ten treatment fractions, tube stability was also assessed. Photon spectra were measured using a high-purity germanium (HPGe) detector, and calculated using MCNP. Parameters used in the two-dimensional (2D) brachytherapy dosimetry formalism were determined. While the Source was characterized as a point due to the small anode size, S700 Source exhibited depth dose behavior similar to low-energy photon-emitting low dose rate sources 125I and l03Pd, yet with capability for variable and much higher dose rates and subsequently adjustable penetration capabilities. This paper presents the calculated and measured in-water brachytherapy dosimetry parameters for the model S700 Source at the aforementioned three operating voltages.

  10. Interstitial rotating shield brachytherapy for prostate cancer

    International Nuclear Information System (INIS)

    Adams, Quentin E.; Xu, Jinghzu; Breitbach, Elizabeth K.; Li, Xing; Rockey, William R.; Kim, Yusung; Wu, Xiaodong; Flynn, Ryan T.; Enger, Shirin A.

    2014-01-01

    Purpose: To present a novel needle, catheter, and radiation source system for interstitial rotating shield brachytherapy (I-RSBT) of the prostate. I-RSBT is a promising technique for reducing urethra, rectum, and bladder dose relative to conventional interstitial high-dose-rate brachytherapy (HDR-BT). Methods: A wire-mounted 62 GBq 153 Gd source is proposed with an encapsulated diameter of 0.59 mm, active diameter of 0.44 mm, and active length of 10 mm. A concept model I-RSBT needle/catheter pair was constructed using concentric 50 and 75 μm thick nickel-titanium alloy (nitinol) tubes. The needle is 16-gauge (1.651 mm) in outer diameter and the catheter contains a 535 μm thick platinum shield. I-RSBT and conventional HDR-BT treatment plans for a prostate cancer patient were generated based on Monte Carlo dose calculations. In order to minimize urethral dose, urethral dose gradient volumes within 0–5 mm of the urethra surface were allowed to receive doses less than the prescribed dose of 100%. Results: The platinum shield reduced the dose rate on the shielded side of the source at 1 cm off-axis to 6.4% of the dose rate on the unshielded side. For the case considered, for the same minimum dose to the hottest 98% of the clinical target volume (D 98% ), I-RSBT reduced urethral D 0.1cc below that of conventional HDR-BT by 29%, 33%, 38%, and 44% for urethral dose gradient volumes within 0, 1, 3, and 5 mm of the urethra surface, respectively. Percentages are expressed relative to the prescription dose of 100%. For the case considered, for the same urethral dose gradient volumes, rectum D 1cc was reduced by 7%, 6%, 6%, and 6%, respectively, and bladder D 1cc was reduced by 4%, 5%, 5%, and 6%, respectively. Treatment time to deliver 20 Gy with I-RSBT was 154 min with ten 62 GBq 153 Gd sources. Conclusions: For the case considered, the proposed 153 Gd-based I-RSBT system has the potential to lower the urethral dose relative to HDR-BT by 29%–44% if the clinician allows

  11. Auger Electron Therapy And Brachytherapy Tumor Treatment

    International Nuclear Information System (INIS)

    Laster, B.H.; Shani, G.

    2002-01-01

    Auger Electron Therapy (AET) is a binary approach for improving cancer radiotherapy. It involves the selective targeting of an atom to tumor cells using physiological pathway. The atom is then irradiated by a specific radiation that produces secondary radiation called Auger electrons. One of the problems associated with the clinical application of AET, is that the energy of the photons required for stimulating photoelectric absorption in most of the available high Z target atoms, is too low to achieve penetration through normal surrounding tissues to the depth of the tumor, when an external source is used. The solution is therefore the use of a brachytherapy technique. There are two other problems associated with the use of radiation as a cancer treatment. The first is the limitation on radiation dose to the normal tissue within the treatment volume. The second problem is the limitation imposed by the miniscule size of the critical target of the cell, namely the DNA (0.25% of the cell mass). The solution to the first problem can be achieved by using the brachytherapy technique. The second problem can be resolved by placing the radiation source in close position to the DNA. AET, as we apply it, provides the two solutions to the two problems. When a photon is absorbed by an electron in the K or L shell of an high Z atom, the electron is ejected from the atom, creating a vacancy in the shell. This vacancy is immediately filled with an electron from an upper shell. The energy difference between the two shells is sometimes emitted as an x-ray, however, frequently the energy is transferred to an outer shell electron that is emitted as an Auger electron. These electrons are emitted at energies of up to ∼30 keV and therefore have a very short range in the cell. They will deposit all their energy within 20-30 nm from the point of emission. i.e. all the energy is deposited in the DNA. In our work indium is used as the high Z atom

  12. The needs for brachytherapy source calibrations in the United States

    International Nuclear Information System (INIS)

    Coursey, B.M.; Goodman, L.J.; Hoppes, D.D.; Loevinger, R.; McLaughlin, W.L.; Soares, C.G.; Weaver, J.T.

    1992-01-01

    Brachytherapy sources of beta and gamma radiation ('brachy' is from the Greek, meaning 'near') have a long history of use in interstitial, intracavitary, intraluminal, and ocular radiation therapy. In the past the US national standards for these sources were often specified in activity or milligram radium equivalent. With the introduction of new radionuclide sources to replace radium, source strength calibrations are now expressed as air kerma rate at a meter. In this paper, we review the NIST standards for brachytherapy sources, list some of the common radionuclides and source encapsulations in use in the US radiology community, and describe the latest NIST work, in collaboration with several US medical institutions, on a method of two- and three-dimensional dose mapping of brachytherapy sources using radiochromic films. (orig.)

  13. Effects of brachytherapy on gene expressions of elastin and elastase

    International Nuclear Information System (INIS)

    Li Junming; Zhou Jingqun; Hu Bin; Li Shuguo

    2004-01-01

    Objective: To study the effects of brachytherapy on the gene expressions of elastin and elastase in cultured rat vascular smooth muscle cells (VSMCs). Methods: Rat VSMCs cultured in DMEM containing 10% FBS were irradiated by 60 Co γ-rays at 0, 7, 14, 28 Gy respectively. Then mRNA levels of elastin and elastase were determined by reverse transcription competitive PCR(RT-PCR). Results: Brachytherapy inhibited the expressions of elastase. Elastase mRNA decreased 25.3% and 50.1% in VSMC irradiated with 14, 28 Gy, respectively (P<0.05). The elastin mRNA level increased 80.7% and 102.3% in VSMC irradiated with 14, 25 Gy, respectively (P<0.05). Conclusion: Brachytherapy inhabits the expressions of elastase and increased elastin in VSMC cells

  14. Indication of brachytherapy of prostate with permanent implants

    International Nuclear Information System (INIS)

    Chauveinc, L.; Solignac, S.; Rosenwald, J.C.; Firmin, F.; Cosset, J.M.; Flam, T.; Thiounn, N.

    2002-01-01

    In the last decade, brachytherapy emerged as a particularly appealing new way of treating localized prostate cancer. Recently published 10-12 years biochemical control results appear to be superimposable to the best percentages achieved by surgery or conformal radiotherapy, with a small percentage of complications. This applied to severely patients. Only patients with T1/T2, PSA 60 g, hip mobility limitations, a urinary obstructive syndrome and previous trans-urethral resection lead to difficulties in technical implantation and therefore must be taken into account when discussing brachytherapy. In conclusion, for adequately selected patients, brachytherapy offers a particularly applied alternative to surgery and external radiotherapy, with satisfactory long term biochemical control rates and limited complications. (author)

  15. Algorithms for the process management of sealed source brachytherapy

    International Nuclear Information System (INIS)

    Engler, M.J.; Ulin, K.; Sternick, E.S.

    1996-01-01

    Incidents and misadministrations suggest that brachytherapy may benefit form clarification of the quality management program and other mandates of the US Nuclear Regulatory Commission. To that end, flowcharts of step by step subprocesses were developed and formatted with dedicated software. The overall process was similarly organized in a complex flowchart termed a general process map. Procedural and structural indicators associated with each flowchart and map were critiqued and pre-existing documentation was revised. open-quotes Step-regulation tablesclose quotes were created to refer steps and subprocesses to Nuclear Regulatory Commission rules and recommendations in their sequences of applicability. Brachytherapy algorithms were specified as programmable, recursive processes, including therapeutic dose determination and monitoring doses to the public. These algorithms are embodied in flowcharts and step-regulation tables. A general algorithm is suggested as a template form which other facilities may derive tools to facilitate process management of sealed source brachytherapy. 11 refs., 9 figs., 2 tabs

  16. Apego y Ajuste Socio Emocional: Un Estudio en Embarazadas Primigestas Attachment and Socio-Emotional Adjustment: A Study in First Pregnant Women

    Directory of Open Access Journals (Sweden)

    Chamarrita Farkas

    2008-05-01

    Full Text Available Este artículo se centra en el estudio del apego adulto y su relación con el ajuste socioemocional durante el primer embarazo. Se utiliza una investigación descriptiva correlacional de carácter transversal. La muestra se compone de 139 embarazadas primigestas de 19 a 40 años y nivel socio-económico medio, medio bajo y bajo. El estilo de apego fue evaluado con el Cuestionario de Apego en Adultos, CaMir, y el ajuste socioemocional con el Cuestionario de Salud Mental, OQ-45.2. Se realizan análisis descriptivos de la muestra y correlaciones entre estilos de apego y las dimensiones del Cuestionario de Ajuste Socioemocional con el Coeficiente Producto Momento de Pearson. Los resultados muestran una relación significativa entre los estilos de apego y los indicadores de ajuste.This article focuses on the study of adult attachment and its relationship with socio-emotional adjustment during the first pregnacy. A correlational descriptive study using a cross-sectional design was conducted. The sample included 139 primípara females between 19 and 40 years of age, from medium, medium-low and low socioeconomic status. The attachment style was evaluated using the Attachment Questionnaire for Adults, CaMir, and the socio-emotional adjustment with the Mental Health Questionnaire, OQ-45.2. Descriptive analyses of the sample were conducted, and the bivariate correlations between attachment styles and adjustment was estimated. The results show a significant relation between attachment styles and adjustment indexes.

  17. Autonomía y ajuste académico: un estudio con estudiantes portugueses de primer año

    Directory of Open Access Journals (Sweden)

    Ana Paula Soares

    2007-01-01

    Full Text Available Los niveles de autonomía psicológica de los alumnos desempeñan un papel importante en su ajuste a las presiones y desafíos de la vida universitaria. En este sentido, el presente estudio descriptivo analiza las relaciones entre los niveles de autonomía de los estudiantes en su entrada en la Enseñanza Superior y la calidad de su ajuste académico al final del primer año. Se aplicó el Iowa Developing Autonomy Inventory (IDAI en el inicio del año lectivo y el Questionário de Vivências Académicas (QVA al final de ese año a una muestra de 420 alumnos de primer año de la Universidade do Minho. Los resultados revelan que los alumnos poseen percepciones bastante positivas en cuanto a sus niveles de autonomía en las áreas de Gestión del tiempo, Movilidad e Interdependencia, y niveles más bajos en la Gestión del dinero, observándose algunas oscilaciones en función del género. Por otro lado, los alumnos cuya entrada en la Enseñanza Superior no implicó su abandono del hogar familiar, especialmente los de sexo masculino, presentan niveles más elevados de ajuste académico. Finalmente, los resultados sugieren que el ajuste académico se encuentra asociado a los niveles de autonomía de los alumnos, en particular en lo que concierne a la Gestión del tiempo, Independencia emocional de sus compañeros e Interdependencia.

  18. Current status of brachytherapy in cancer treatment – short overview

    Directory of Open Access Journals (Sweden)

    Janusz Skowronek

    2017-12-01

    Full Text Available Cancer incidence and mortality depend on a number of factors, including age, socio-economic status and geographical location, and its prevalence is growing around the world. Most of cancer treatments include external beam radiotherapy or brachytherapy. Brachytherapy, a type of radiotherapy with energy from radionuclides inserted directly into the tumor, is increasingly used in cancer treatment. For cervical and skin cancers, it has become a standard therapy for more than 100 years as well as an important part of the treatment guidelines for other malignancies, including head and neck, skin, breast, and prostate cancers. Compared to external beam radiotherapy, brachytherapy has the potential to deliver an ablative radiation dose over a short period of time directly to the altered tissue area with the advantage of a rapid fall-off in dose, and consequently, sparing of adjacent organs. As a result, the patient is able to complete the treatment earlier, and the risks of occurrence of another cancer are lower than in conventional radiotherapy treatment. Brachytherapy has increased its use as a radical or palliative treatment, and become more advanced with the spread of pulsed-dose-rate and high-dose-rate afterloading machines; the use of new 3D/4D planning systems has additionally improved the quality of the treatment. The aim of the present study was to present short summaries of current studies on brachytherapy for the most frequently diagnosed tumors. Data presented in this manuscript should help especially young physicians or physicists to explore and introduce brachytherapy in cancer treatments.

  19. Brachytherapy for elderly patients with stage II tongue cancer

    International Nuclear Information System (INIS)

    Kimura, Tomoki; Hirokawa, Yutaka; Fujita, Minoru; Murakami, Yuji; Kenjo, Masahiro; Kaneyasu, Yuko; Ito, Katsuhide

    2003-01-01

    In treatment choices of stage II (T2N0M0) tongue cancer, brachytherapy is less invasive and superior in function preservation, therefore its role is more important in elderly patients. The aim of this study was to evaluate treatment results and morbidity of brachytherapy for elderly patients with stage II tongue cancer. Between 1980 and 2001, 198 patients with stage II tongue cancer were treated with brachytherapy at Hiroshima University Hospital. Patient ages ranged from 21 to 89 years old (median: 62 years old). Patients were divided into three groups as follows: 119 patients younger than 65 years old (Non-Elderly group), 53 patients between 65 and 75 years old (Junior Elderly group), and 26 patients 75 years or older (Senior Elderly group). Radiotherapy was performed in 101 patients with brachytherapy alone, and in 97 patients with brachytherapy and external radiotherapy. Chemotherapy was also performed in 77 patients. Follow-up period ranged from 4 to 243 months (median: 55 months). The 5-year local control rate was 85% in the Non-Elderly group, 85% in the Junior Elderly group and 81% in the Senior Elderly group. There was no significant difference among these groups. The 5-year cause-specific survival rate was 85%, 81% and 70% respectively. The Senior Elderly group showed poorer cause-specific survival rate than the other two groups (p=0.03). There was also a tendency of higher incidence of neck metastasis and low salvage rate by neck dissection in the Senior Elderly group. Although the Senior Elderly group showed poorer cause-specific survival rate, the local control rate was similar to those of the other two groups. Brachytherapy is an effective treatment option for elderly patients with stage II tongue cancer. (author)

  20. Brachytherapy in vulvar cancer: analysis of 18 patients

    International Nuclear Information System (INIS)

    Frezza, G.; Baldissera, A.; Bernardi, L.; Bunkheila, F.; Galuppi, A.; Salvi, F.

    1996-01-01

    INTRODUCTION: Vulvar cancer is a rather common neoplasm in elderly patients. Surgery, followed eventually by postoperative radiotherapy, is the treatment of choice. The results of exclusive radiotherapy (external beam irradiation and/or brachytherapy) are not well defined and in the recent literature only small series are reported. Radiotherapy however is the only therapeutic option in patients who are not fit for radical surgery. It is thus necessary to review its indications and its modalities. PATIENTS METHODS AND RESULTS: From 1990 to 1994 18 pts with a diagnosis of squamous cell carcinoma of the vulva have been submitted to brachytherapy. Age ranged from 60 to 92 years (mean age 76, 1 ys). 14 pts were treated at diagnosis (11 pts) or for recurrent disease after surgery (3 pts). In 8 of them brachytherapy (total dose 35-45 Gy, dose rate: 0,4-0,78 Gy/h) was preceded by external beam irradiation (Co60 or electron beam, 40-50 Gy to primary and inguinal nodes); 6 pts were treated with brachytherapy alone (58-60 Gy; dose rate 0,44-0,63 Gy/h). 4 pts underwent to brachytherapy alone for local recurrence after surgery and postoperative radiotherapy (total dose 45-60 Gy; dose rate 0,37-0,49 Gy/h). Brachytherapy was always performed with 192 Ir. Plastic tubes (2 to 5 lines) were used for single plane implantation of small exophytic lesions limited to the labia (8 cases); a perineal template (10 cases) was employed in lesions extended to the vaginal mucosa or involving the clitoris or the area of the perineum. (10(14)) pts treated at diagnosis are alive and free from local recurrence after 11-48 mos. 3 of them, treated with brachytherapy alone, have presented a nodal recurrence in the groin after 14, 15 and 27 mos. respectively. All of them are alive and free from disease after surgery and external radiotherapy. None of the pts treated for recurrent disease after surgery + external beam radiotherapy has achieved a local control. CONCLUSION: Brachytherapy alone or

  1. Volume correction factor in time dose relationships in brachytherapy

    International Nuclear Information System (INIS)

    Supe, S.J.; Sasane, J.B.

    1987-01-01

    Paterson's clinical data about the maximum tolerance doses for various volumes of interstitial implants with Ra-226 delivered in seven days was made use of in deriving volume correction factors for TDF and CRE concepts respectively for brachytherapy. The derived volume correction factors for TDF and for CRE differ fromthe one assumed for CRE by Kirk et al. and implied for TDF by Goitein. A normalising volume of 70 cc has been suggested for both CRE and TDF concepts for brachytherapy. A table showing the volume corrected TDF is presented for various volumes and dose rates for continuous irradiation. The use of this table is illustrated with examples. (orig.) [de

  2. Complications of esophageal stenting after radiotherapy and brachytherapy

    Energy Technology Data Exchange (ETDEWEB)

    Yorozu, Atsunori; Dokiya, Takushi; Ogita, Mikio; Kutuki, Shoji; Oki, Yosuke [National Second Hospital of Tokyo (Japan)

    1997-11-01

    The purpose of our study was to evaluate safety and complications of stenting after radiotherapy and brachytherapy. Fifteen of 21 patients showed improvement of dysphagia by stenting. But 6 of 21 patients had perforation or massive bleeding relating to stents. The risk for perforation or hemorrhage appears to be even higher in patients who have previously undergone radical radiotherapy and brachytherapy within one month before stenting. Stenting at 6 months or more after radical radiotherapy seems to be an effective and safe method of long-lasting palliation for severe dysphagia with recurrent esophageal cancer. (author)

  3. Australian high-dose-rate brachytherapy protocols for gynaecological malignancy

    International Nuclear Information System (INIS)

    MacLeod, C.; Dally, M.; Stevens, M.; Thornton, D.; Carruthers, S.; Jeal, P.

    2001-01-01

    There is no consensus over the optimal dose fractionation schedules for high-dose-rate (HDR) brachytherapy used for gynaecological malignancy. In Australian public hospital departments of radiation oncology, HDR brachytherapy for gynaecological cancer is being more commonly used. A survey of public departments that are using this technology, or that plan to introduce this technology, was performed. Their current protocols are presented. In general, protocols are similar biologically; however, the practical aspects such as the number of fractions given do vary and may reflect resource restrictions or, alternatively, differences in interpretations of the literature and of the best protocols by clinicians. Copyright (2001) Blackwell Science Pty Ltd

  4. Radiographic Control of 137-Cs Brachytherapy Sources

    International Nuclear Information System (INIS)

    Bistrovic, M.; Viculin, T.; Jurkovic, S.

    2003-01-01

    1 37C s brachytherapy sources are practical for the intracavitary application due to their relatively long lifetime (T 1/2 = 30 y). On the other hand, due to the relatively low energy (0.66 MeV) of the emitted photons, they are suitable for an efficient radiation protection. The dose distribution around the sources is usually calculated by a specific program. However this program requires the knowledge of the position of sources within the applicator as well as the distribution of activity along them. The only way to learn these data is to make an X-ray picture of applicators and sources superimposed to the autoradiography of every source. It is difficult to achieve satisfactory radiographs with high dose rate sources with standard X-ray film material because autoradiography covers the structure of the radiographic shadow. The problem can be overcome either by applying a high intensity X-ray or gamma beam (originating from a radiotherapeutic machine), or by using photographic material of very low sensitivity, for example photographic paper. Combining both possibilities one can obtain satisfactory images. (author)

  5. Endovascular brachytherapy to prevent restenosis after angioplasty

    International Nuclear Information System (INIS)

    Wohlgemuth, W.A.; Bohndorf, K.

    2003-01-01

    Endovascular radiotherapy is the first effective prophylaxis of restenosis after percutaneous transluminal angioplasty (PTA) and stenting. The FDA recently approved two devices for the delivery of intracoronary radiation following coronary artery stenting. Published multicenter, double-blind, randomized trials of intracoronary radiation therapy report good results for preventing in-stent restenosis, while the data for the peripheral circulation are still inconclusive. Beta-emitters are easier applicable and probably also safer, whereas gamma-emitters have been more extensively evaluated clinically so far. Primary indication for endovascular brachytherapy are patients at high risk for restenosis, such as previous restenoses, in-stent hyperplasia, long stented segment, long PTA lesion, narrow residual vascular lumen and diabetes. Data from coronary circulation suggest a safety margin of at least 4 to 10 mm at both ends of the angioplastic segment to avoid edge restenosis. To prevent late thrombosis of the treated coronary segment, antiplatelet therapy with clopidogrel and aspirin are recommended for at least 6 months after PTA and for 12 months after a newly implanted stent. An established medication regimen after radiotherapy of peripheral arteries is still lacking. (orig.) [de

  6. A quality management program in intravascular brachytherapy

    International Nuclear Information System (INIS)

    Chakri, Abderrahim; Thomadsen, Bruce

    2002-01-01

    While simple, intravascular brachytherapy (IVB) presents a considerable potential for harm to the patient. The medical physicist maintains the responsibility to minimize the likelihood of operational problems or dosimetric errors. The principals for safe operation remain the same as with any radiotherapy treatment: to deliver the correct dose, to the correct location, safety. To develop an effective and comprehensive quality management (QM) program for IVB, a physicist should utilize proven risk assessment techniques rather than simply thinking of things to check, and follow guidances such as ISO9001:2000. The proposed QM program includes the following: Procedures designed to assure the safety of the patient: Identification of the patient; tests of the integrity and patency for the delivery catheter, operation of the source train, and patency of the catheter in the treatment position; a check for recovery preparations; and verification of source recovery. Procedures to assure positional accuracy of the treatment: Verification of the positioning the catheter in the artery and of the sources in the catheter. Procedures to assure dosimetry accuracy: Acceptance testing of the device, including verification of the source strength and uniformity, and of the treatment duration tables; verification of the treatment prescription and duration for each patient; and control measures that minimize the likelihood of errors removing the source at the correct time

  7. Radiation safety parameters following prostate brachytherapy

    International Nuclear Information System (INIS)

    Smathers, Sesalie; Wallner, Kent; Korssjoen, Tammy; Bergsagel, Carl; Hudson, Rick H.; Sutlief, Steven; Blasko, John

    1999-01-01

    Purpose: To determine the degree and variability of radiation exposure to the general public from patients after I-125 or Pd-103 prostate brachytherapy. Methods and Materials: Radiation exposure measurements were made from 38 consecutive, unselected patients with stage T1 or T2 prostatic carcinoma who had trans perineal I-125 or Pd-103 implants at the University of Washington in 1998. Results: The exposure rate at the anterior skin surface following a I-125 implant ranged from 2.2 to 8.9 mrem/hour (average: 5.0). The exposure rate at the anterior skin surface from a Pd-103 implant ranged from 0.5 to 4.9 mrem/hour (average: 1.7). Based on the current Nuclear Regulatory Commission (NRC) regulations the time required to reach the annual limit at the anterior skin surface would be 20 hours for I-125 and 59 hours for Pd-103. For exposure at the lateral skin surface, the times would exceed 500 hours for either isotope. Conclusions: This data suggest that patients need not be concerned about being a radiation risk to the general public following their procedure

  8. Radiation Protection Training in Intracoronary Brachytherapy

    International Nuclear Information System (INIS)

    Prieto, C.; Vano, E.; Fernandez, J. M.; Sabate, M.; Galvan, C.; Meiggs, L.; Corral, J. M.

    2003-01-01

    To report the educational objectives and contents on Radiation Protection (RP) for the practice of Intracoronary Brachytherapy (ICB) procedures. The wide international experience on training programs for ICB as well as our own experience organizing several courses aimed at Cardiologists, Radio therapists and Medical Physicists has been used to elaborate specific RP objectives and contents. The objectives, differentiated for Cardiologists, Radio therapists, Medical Physicists, Nurses and Technicians, pretend to guarantee the safety and RP of both patient and staff in the procedures of ICB. The objectives are necessarily different because their RP formation and their role in the procedure are different. The general topics included in RP training programmes for ICB could be: general topics on RP (Interaction of radiation and matter, RP principles, radiobiology, etc), principles of operation of ICB and interventional X-ray equipment, quantification of radiation dose and risks, optimisation of protection of staff and patients, accidents and emergencies, regulations, responsibilities, quality assurance program, handling of ICB sources, installation and commissioning. Training programs based on the objectives presented in this paper would encourage positive safety culture in ICB and can also be used as a starting point by the Regulatory Authority for the authorization of new Installations and credentialing of professionals involved in this technique as well as for the continuous education of the staff involved. (Author) 10 refs

  9. Dose assessment for brachytherapy with Henschke applicator

    International Nuclear Information System (INIS)

    Yu, Pei-Chieh; Chao, Tsi-Chian; Tung, Chuan-Jong; Wu, Ching-Jung; Lee, Chung-Chi

    2011-01-01

    Dose perturbation caused by the Henschke applicator is a major concern for the brachytherapy planning system (BPS) in recent years. To investigate dose impact owing to neglect of the metal shielding effect, Monte Carlo (MC) simulation, BPS calculation, and film measurement have been performed for dose assessment in a water phantom. Additionally, a cylindrical air cavity representing the rectum was added into the MC simulation to study its effect on dose distribution. Monte Carlo N-Particle Transport Code (MCNP) was used in this study to simulate the dose distribution using a mesh tally. This Monte Carlo simulation has been validated using the TG-43 data in a previous report. For the measurement, the Henschke applicator was placed in a specially-designed phantom, and Gafchromic films were inserted in the center plane for 2D dose assessment. Isodose distributions with and without the Henschke applicator by the MC simulation show significant deviation from those by the BPS. For MC simulation, the isodose curves shrank more significantly when the metal applicator was applied. For the impact of the added air cavity, the results indicate that it is hard to distinguish between with and without the cavity. Thus, the rectum cavity has little impact on the dose distribution around the Henschke applicator.

  10. Dose optimisation in single plane interstitial brachytherapy

    DEFF Research Database (Denmark)

    Tanderup, Kari; Hellebust, Taran Paulsen; Honoré, Henriette Benedicte

    2006-01-01

    patients,       treated for recurrent rectal and cervical cancer, flexible catheters were       sutured intra-operatively to the tumour bed in areas with compromised       surgical margin. Both non-optimised, geometrically and graphically       optimised CT -based dose plans were made. The overdose index...... on the       regularity of the implant, such that the benefit of optimisation was       larger for irregular implants. OI and HI correlated strongly with target       volume limiting the usability of these parameters for comparison of dose       plans between patients. CONCLUSIONS: Dwell time optimisation significantly......BACKGROUND AND PURPOSE: Brachytherapy dose distributions can be optimised       by modulation of source dwell times. In this study dose optimisation in       single planar interstitial implants was evaluated in order to quantify the       potential benefit in patients. MATERIAL AND METHODS: In 14...

  11. Halo's production in vitro on brachytherapy experiments

    International Nuclear Information System (INIS)

    Cuperschmid, Ethel M.; Sarmento, Eduardo V.; Campos, Tarcisio P.R.

    2011-01-01

    Since earlier of 1960, one of the most significant contributions of radiation biology has been the theory of cell killing as a function of increasing doses of a cytotoxic agent, as well as the demonstration of repair of sublethal or potentially lethal damage after irradiation. The impact of cellular and molecular radiobiology, by exploitation of cellular mechanisms related to apoptosis, may be the cell killing with irradiation by including changes other than unrepaired DNA damage. Based on the understanding of the tumor microenvironment and how growth factors and proteins produced by irradiated cells may alter cellular processes, improved combined-modality strategies may emerge. This effect was show since 1960's, but here we propose to demonstrate this phenomenon in Brachytherapy. The present goal is to verify the macroscopic response through the production and analysis of clonogenic control based on halos generation by radioactive seeds of Ho-165 and Sm-153, aiming to study the effect of this type of irradiation. Confluent cell culture flasks with HeLa cell line were subjected to radiation in a period up to five half-lives of radionuclide, respectively. Devices were introduced which set the polymer-ceramic Ho-165 and Sm-153 seeds in the vials. After a period of exposure, the flasks were stained with violet Gensiana. The results showed the formation of halos control of confluent cancer cells. This paper will describe these experiments in the current stage of the research and report the implications of this new way of therapy for cancer treatment. (author)

  12. Disputas, ajustes e acomodações na produção da agenda eleitoral: a cobertura jornalística ao Programa Bolsa Família e as eleições de 2006

    Directory of Open Access Journals (Sweden)

    Flávia Biroli

    2010-06-01

    Full Text Available Resumo: Este artigo apresenta uma análise da cobertura jornalística ao Programa Bolsa Família durante as eleições presidenciais de 2006. A pesquisa abrange um total de 166 textos que mencionaram o Programa, publicados pelos jornais O Globo, O Estado de São Paulo, Folha de São Paulo e Valor Econômico entre os dias 1º de setembro e 31 de outubro de 2006. Discutimos a dinâmica de produção da agenda eleitoral, observando as disputas, ajustes e acomodações que constituem a cobertura. A análise conjunta das vozes e dos enquadramentos presentes no material permite observar aspectos relevantes das interações entre os campos da mídia e da política no contexto em que a cobertura foi realizada. As conclusões ressaltam a baixa pluralidade do noticiário, associada a representações das eleições de 2006 e da democracia brasileira que têm como aspectos centrais a estigmatização dos eleitores de baixa renda e dos beneficiários de programas sociais.Abstract: This article presents an analysis of the news about an important social program maintained by the federal government, Programa Bolsa Família, in the period of brazilian major elections of 2006. The study is based in 166 texts published in the newspapers O Globo, O Estado de São Paulo, Folha de São Paulo e Valor Econômico between September 1st and October 31st. We discuss the production of electoral agenda, observing disputes, adjustments and acommodations that constitute news coverage. The analysis of voices and framings in the texts leads to the observation of relevant aspects of the relations between media and politics at that moment. Conclusions underline the low plurality in press coverage, connected to representations of the elections of 2006 and Brazilian democracy that include stigmatization of low income voters and beneficiaries of social programs.

  13. Underuse of brachytherapy for the treatment of dysphagia owing to esophageal cancer. An Italian survey.

    Science.gov (United States)

    Fuccio, Lorenzo; Guido, Alessandra; Hassan, Cesare; Frazzoni, Leonardo; Arcelli, Alessandra; Farioli, Andrea; Giaccherini, Lucia; Galuppi, Andrea; Mandolesi, Daniele; Cellini, Francesco; Mantello, Giovanna; Macchia, Gabriella; de Bortoli, Nicola; Repici, Alessandro; Valentini, Vincenzo; Bazzoli, Franco; Morganti, Alessio Giuseppe

    2016-10-01

    International guidelines strongly recommend brachytherapy as valid alternative or in addition to stenting in patients with dysphagia owing to esophageal cancer. However, for not well understood reasons, brachytherapy is definitively underused for the palliative treatment of malignant dysphagia. Aim of the current survey was to investigate the use of brachytherapy for the treatment of malignant dysphagia in Italy. A structured questionnaire was submitted to the 1510 members of the Italian Association of Radiation Oncologists (AIRO). These members refer to 177 centres of radiotherapy across Italy and in 68 (38.4%) of them brachytherapy is routinely performed. Of the 1510 invited members, 178 completed the survey (11.7%). The answers provided by the 178 participants allowed to get information on 40 out of 68 brachytherapy centres (58.8%). Seven out of 40 (17.5%) centres perform brachytherapy of the oesophagus, in 3 out of 40 (7.5%) centres brachytherapy represents the first line of treatment. The main reason why brachytherapy is not routinely performed is the lack of experience. Despite the strong recommendations of the international guidelines and the wide diffusion of brachytherapy centres across Italy, only very few of them routinely considered brachytherapy for the treatment of dysphagia due to esophageal cancer. Copyright © 2016 Editrice Gastroenterologica Italiana S.r.l. Published by Elsevier Ltd. All rights reserved.

  14. Los Programas de Desarrollo Rural en la Argentina (en el contexto del ajuste macroeconómico neoliberal

    Directory of Open Access Journals (Sweden)

    Mabel Manzanal

    2000-09-01

    Full Text Available Este trabajo expone las estrategias de los principales programas de desarrollo rural en la Argentina, y sus alcances y posibilidades en el contexto del ajuste macroeconómico neoliberal. Discute si se están dando, o no, los cursos de acción adecuados, y si es viable la asistencia a los pobres rurales, promovida por los organismos internacionales de financiamiento, frente al impacto negativo de las políticas neoliberales sobre los pequeños y medianos productores agropecuarios.El desarrollo rural se inicia en la Argentina junto con la recuperación democrática de la década del 80, pero las primeras acciones recién comienzan a ejecutarse a principios de los 90. Desde entonces se sucedieron y se superpusieron diferentes programas, que son el objeto de este artículoThis paper discusses the strategies of Argentina’s main rural development programs, and their accomplishments and possibilities in the context of neoliberal macroeconomic adjustment. It analyzes whether the actions being carried out are suitable and whether assistance to the rural poor (promoted by international financing organizations is feasible in the face of the neoliberal policies’ negative impact on small and intermediate farmers and ranchers. Although rural development programs began in Argentina with the restoration of democracy in the 1980s, the first significant actions were not taken until the 1990s. The different programs that have followed, often overlapping, are the object of our study

  15. O ecologismo dos pobres

    Directory of Open Access Journals (Sweden)

    Juan Martinez ALIER

    1997-12-01

    Full Text Available O ecologísmo tem colocado em cheque as leis capitalistas de mercado, principalmente na sua fase globalizada, devido à apropriação e exploração inconsequente dos recursos naturais. Ao mesmo tempo tem apontado que o meio ambiente não se reduz ao tratamento somente cientifico da natureza. O presente artigo ressalta aspectos importantes do ecologísmo como a participação das mulheres, o marxismo, o neo-narodnismo, etc. e é rico em exemplos de problemas ambientais decorrentes das relações de produção. O ecologísmo dos pobres é apontado como uma perspectiva necessária às lutas ambientais no Terceiro Mundo.

  16. Current status of brachytherapy in Korea: a national survey of radiation oncologists.

    Science.gov (United States)

    Kim, Haeyoung; Kim, Joo Young; Kim, Juree; Park, Won; Kim, Young Seok; Kim, Hak Jae; Kim, Yong Bae

    2016-07-01

    The aim of the present study was to acquire information on brachytherapy resources in Korea through a national survey of radiation oncologists. Between October 2014 and January 2015, a questionnaire on the current status of brachytherapy was distributed to all 86 radiation oncology departments in Korea. The questionnaire was divided into sections querying general information on human resources, brachytherapy equipment, and suggestions for future directions of brachytherapy policy in Korea. The response rate of the survey was 88.3%. The average number of radiation oncologists per center was 2.3. At the time of survey, 28 centers (36.8%) provided brachytherapy to patients. Among the 28 brachytherapy centers, 15 (53.5%) were located in in the capital Seoul and its surrounding metropolitan areas. All brachytherapy centers had a high-dose rate system using (192)Ir (26 centers) or (60)Co (two centers). Among the 26 centers using (192)Ir sources, 11 treated fewer than 40 patients per year. In the two centers using (60)Co sources, the number of patients per year was 16 and 120, respectively. The most frequently cited difficulties in performing brachytherapy were cost related. A total of 21 centers had a plan to sustain the current brachytherapy system, and four centers noted plans to upgrade their brachytherapy system. Two centers stated that they were considering discontinuation of brachytherapy due to cost burdens of radioisotope source replacement. The present study illustrated the current status of brachytherapy in Korea. Financial difficulties were the major barriers to the practice of brachytherapy.

  17. O Jardim dos Sonhos

    Directory of Open Access Journals (Sweden)

    RAUL CÂNOVAS

    2010-06-01

    Full Text Available O jardim dos sonhos sempre foi um ideal dos homens. No Antigo Egito, já se falava em um jardim sempre verde para onde as pessoas de bom coração iam após a morte. E na mitologia grega, um lindo jardim era palco das festas bucólicas dos deuses. As grandes religiões também citavam jardins como paraísos, como o Jardim do Éden. Neste artigo, Raul Cânovas nos leva a refletir sobre o sentido de um “jardim perfeito”, sem tratar a perfeição como apenas plástica e estruturada com exatidão, mas referindo-se a um jardim que nos inspire e emocione, emancipado de modismos passageiros. O paisagista também nos alerta sobre as condições mutáveis de um jardim, que nunca está finalizado. O paisagismo não é apenas técnica; é também sensibilidade, utilidade, sustentabilidade e equilíbrio das forças da natureza.

  18. Electromagnetic tracking for treatment verification in interstitial brachytherapy

    DEFF Research Database (Denmark)

    Bert, Christoph; Kellermeier, Markus; Tanderup, Kari

    2016-01-01

    Electromagnetic tracking (EMT) is used in several medical fields to determine the position and orientation of dedicated sensors, e.g., attached to surgical tools. Recently, EMT has been introduced to brachytherapy for implant reconstruction and error detection. The manuscript briefly summarizes...

  19. Pulsed dose rate brachytherapy – is it the right way?

    Directory of Open Access Journals (Sweden)

    Janusz Skowronek

    2010-10-01

    Full Text Available Pulsed dose rate (PDR-BT treatment is a brachytherapy modality that combines physical advantages of high-doserate (HDR-BT technology (isodose optimization, radiation safety with the radiobiological advantages of low-dose-rate (LDR-BT brachytherapy. Pulsed brachytherapy consists of using stronger radiation source than for LDR-BT and producing series of short exposures of 10 to 30 minutes in every hour to approximately the same total dose in the sameoverall time as with the LDR-BT. Modern afterloading equipment offers certain advantages over interstitial or intracavitaryinsertion of separate needles, tubes, seeds or wires. Isodose volumes in tissues can be created flexibly by a combinationof careful placement of the catheter and the adjustment of the dwell times of the computerized stepping source.Automatic removal of the radiation sources into a shielded safe eliminates radiation exposures to staff and visitors.Radiation exposure is also eliminated to the staff who formerly loaded and unloaded multiplicity of radioactive sources into the catheters, ovoids, tubes etc. This review based on summarized clinical investigations, analyses the feasibility and the background to introduce this brachytherapy technique and chosen clinical applications of PDR-BT.

  20. Brachytherapy in Europe: philosophies, current practice and future directions

    International Nuclear Information System (INIS)

    Haworth, A.

    2000-01-01

    Full text: Five months sabbatical leave provided an opportunity to visit six radiotherapy centres in France, Holland and England. While brachytherapy philosophies and practices within each country were similar, there were considerable differences in attitudes between countries. The Institute Gustave Roussy, home of the Paris System and host for the French sector confirmed that the Paris System is still very much the preferred dosimetry method in this part of the world. Though their preference for low dose rate brachytherapy is still evident, high dose rate brachytherapy has found some applications but the rules of the Paris System are never far away and the words 'what about the hyperdose sleeve' are firmly implanted into this visitor's brain. The use of real time dosimetry for I-125 prostate brachytherapy at the Institute Curie (Paris) provided an interesting contrast to the standard pre and post implant dosimetry techniques commonly employed elsewhere. The two Dutch centres on the itinerary, in stark contrast to the traditional techniques seen in France, have applied the power of computers to investigate optimisation of the classic dosimetry systems and called on the analysis techniques (DVH, NTCP, TCP etc) now familiar to us all in external beam therapy. The Cookridge Hospital in England fitted somewhere between the French and Dutch centres. This centre showed how both modern and traditional techniques could be applied in an efficient way for a large variety of treatment sites. Copyright (2000) Australasian College of Physical Scientists and Engineers in Medicine

  1. In vivo dosimetry: trends and prospects for brachytherapy

    DEFF Research Database (Denmark)

    Kertzscher, Gustavo; Rosenfeld, A.; Beddar, S.

    2014-01-01

    The error types during brachytherapy (BT) treatments and their occurrence rates are not well known. The limited knowledge is partly attributed to the lack of independent verification systems of the treatment progression in the clinical workflow routine. Within the field of in vivo dosimetry (IVD)...

  2. Source of hope [El Salvador’s only brachytherapy centre

    International Nuclear Information System (INIS)

    Falcon Castro, Nancy

    2010-01-01

    Set up in 2008 with the IAEA’s support, the Cancer Institute 'Dr. Narciso Diaz Bazan' is El Salvador’s only brachytherapy treatment facility for women affected by uterine cancer. To date, over 1000 women affected by cervical cancer have received treatment in the centre

  3. Urethral toxicity after LDR brachytherapy: experience in Japan.

    Science.gov (United States)

    Tanaka, Nobumichi; Asakawa, Isao; Hasegawa, Masatoshi; Fujimoto, Kiyohide

    2015-01-01

    Urinary toxicity is common after low-dose-rate (LDR) brachytherapy, and the resolution of urinary toxicity is a concern. In particular, urinary frequency is the most common adverse event among the urinary toxicities. We have previously reported that approximately 70% of patients experience urinary frequency during the first 6 months after seed implantation. Most urinary adverse events were classified as Grade 1, and Grade 2 or higher adverse events were rare. The incidence of urinary retention was approximately 2-4%. A high International Prostate Symptom Score before seed implantation was an independent predictor of acute urinary toxicity of Grade 2 or higher. Several previous reports from the United States also supported this trend. In Japan, LDR brachytherapy was legally approved in 2003. A nationwide prospective cohort study entitled Japanese Prostate Cancer Outcome Study of Permanent Iodine-125 Seed Implantation was initiated in July 2005. It is an important issue to limit urinary toxicities in patients who undergo LDR brachytherapy. Copyright © 2015 American Brachytherapy Society. Published by Elsevier Inc. All rights reserved.

  4. Endobronchial brachytherapy: the Saint-Louis Hospital experience

    International Nuclear Information System (INIS)

    Hennequin, C.; Durdux, C.; Housset, M.; Maylin, C.; Tredaniel, J.; Zalcman, G.; Hirsch, A.; Dray, M.; Manoux, D.; Perret, M.

    1997-01-01

    During the evolution of lung cancer, bronchial obstruction is often noticed and is sometimes responsible for serious symptoms. Several methods of des-obstruction can be proposed, including brachytherapy. Materials and methods: One hundred forty-nine patients, presenting with endobronchial brachytherapy were included into the study. Seventy-three were treated with curative intent, 47 with palliative intent and 29 with a combination of external irradiation and brachytherapy. We usually delivered a series of two 7-Gy fractions (1 cm from the catheter), the treatment being repeated one, two or three times. Results: When all symptoms were taken into account, respiratory function improvement was present in 79% of the patients. Among the 132 tumors that could be evaluated via a new endoscopy 2 months after treatment, 64 (48.5%) were in complete histological remission. The median survival was 14.4 months for the patients treated with curative intent. Eleven massive hemoptyses and 13 radiation bronchitides were observed. Conclusion: These results confirm the feasibility and good results related to endobronchial brachytherapy, though controlled studies are needed to better define its place in the therapeutic strategy of bronchial carcinomas. (authors)

  5. Brachytherapy in cervix cancers: techniques and concepts evolution

    International Nuclear Information System (INIS)

    Haie-Meder, C.; Crevoisier, R. de; Petrow, P.; Fromm, S.; Delapierre, M.; Albano, M.; Petit, C.; Briot, E.

    2003-01-01

    Brachytherapy plays an important role in the treatment of patients with cervical carcinoma. Technical modalities have evolved during the last years and have benefited from imaging modalities development, specially MRI. Imaging modalities contribute to a better knowledge of tumoral extension and critical organs. Ultrasound during brachytherapy has led to the almost complete eradication of uterine perforation. In the future, a more systematic use of systems allowing optimization may induce a better dose distribution in the tumor as well as in the critical organs. Recent data provided information in favor of a better analysis in the relative role of dose-rate, total dose and treated volume and their influence on the local control and complication incidence. Concomitant radio-chemotherapy represents a standard in the treatment of patients with tumoral size exceeding 4 cm. Some questions still remain: is concomitant chemotherapy of benefit during brachytherapy? Is there any place for complementary surgery, specially in patients with complete response after external irradiation with concomitant chemotherapy and brachytherapy? In order to answer the former question, a phase III randomized trial is going to start, with the Federation Nationale des Centres de Lutte Contre le Cancer as a promoter. (authors)

  6. Radiation exposure of nursing personnel to brachytherapy patients

    International Nuclear Information System (INIS)

    Cobb, P.D.; Kase, K.R.; Bjaerngard, B.E.

    1978-01-01

    The radiation exposure of nursing personnel to brachytherapy patients has been analyzed from data collected during the years 1973-1976, at four different hospitals. The average annual dose per exposed nurse ranged between 25 and 150 mrem. The radiation exposure per nurse was found to be proportional to the total potential exposure and was uncorrelated with the size of the nursing staff. (author)

  7. Dose determination in breast tumor in brachytherapy using Iridium-192

    International Nuclear Information System (INIS)

    Okuno, S.F.

    1984-01-01

    Thermoluminescent dosimetry studies in vivo and in vitro aiming to determing radiation dose in the breast tumor, in brachytherapy using Iridium-192 was done. The correlation between radiation doses in tumor and external surface of the breast was investigated for correcting the time interval of radiation source implantation. (author) [pt

  8. Radiation exposure after permanent prostate brachytherapy

    International Nuclear Information System (INIS)

    Cattani, Federica; Vavassori, Andrea; Polo, Alfredo; Rondi, Elena; Cambria, Raffaella; Orecchia, Roberto; Tosi, Giampiero

    2006-01-01

    Background and purpose: Limited information is available on the true radiation exposure and associated risks for the relatives of the patients submitted to prostate brachytherapy with permanent implant of radioactive sources and for any other people coming into contact with them. In order to provide appropriate information, we analyzed the radiation exposure data from 216 prostate cancer patients who underwent 125 I or 103 Pd implants at the European Institute of Oncology of Milan, Italy. Patients and methods: Between October 1999 and October 2004, 216 patients with low risk prostate carcinoma were treated with 125 I (200 patients) or 103 Pd (16 patients) permanent seed implantation. One day after the procedure, radiation exposure measurements around the patients were performed using an ionization chamber survey meter (Victoreen RPO-50) calibrated in dose rate at an accredited calibration center (calibration Centre SIT 104). Results: The mean dose rate at the posterior skin surface (gluteal region) following 125 I implants was 41.3 μSv/h (range: 6.2-99.4 μSv/h) and following 103 Pd implants was 18.9 μSv/h (range 5.0-37.3 μSv/h). The dose rate at 50 cm from the skin decreased to the mean value of 6.4 μSv/h for the 125 I implants and to the mean value of 1.7 μSv/h for the 103 Pd implants. Total times required to reach the annual dose limit (1 mSv/year) recommended for the general population by the European Directive 96/29/Euratom and by the Italian law (Decreto Legislativo 241/2000) at a distance of 50 cm from the posterior skin surface of the implanted patient would be 7.7 and 21.6 days for 125 I and for 103 Pd. Good correlation between the measured dose rates and both the total implanted activity and the distance between the most posteriorly implanted seed and the skin surface of the patients was found. Conclusions: Our data show that the dose rates at 50 cm away from the prostate brachytherapy patients are very low and that the doses possibly absorbed by the

  9. Isotope selection for patients undergoing prostate brachytherapy

    International Nuclear Information System (INIS)

    Cha, Christine M.; Potters, Louis; Ashley, Richard; Freeman, Katherine; Wang Xiaohong; Waldbaum, Robert; Leibel, Steven

    1999-01-01

    Purpose: Ultrasound-guided trans perineal interstitial permanent prostate brachytherapy (TIPPB) is generally performed with either 103 Pd or 125 I. The use of 125 I for low Gleason score tumors and 103 Pd for higher Gleason scores has been suggested based on isotope dose rate and cell doubling time observed in in vitro studies. While many centers follow these isotope selection criteria, other centers have elected to use only a single isotope, regardless of Gleason score. No clinical data have been published comparing these isotopes. This study was undertaken to compare outcomes between 125 I and 103 Pd in a matched pair analysis for patients undergoing prostate brachytherapy. Methods and Materials: Six hundred forty-eight consecutively treated patients with clinically confined prostate cancer underwent TIPPB between June 1992 and February 1997. Five hundred thirty-two patients underwent TIPPB alone, whereas 116 received pelvic external beam irradiation and TIPPB. Ninety-three patients received androgen deprivation therapy prior to TIPPB. The prescribed doses for TIPPB were 160 Gy for 125 I (pre-TG43) and 120 Gy for 103 Pd. Patients treated with combination therapy received 41.4 or 45 Gy (1.8 Gy/fraction) external beam irradiation followed by a 3- to 5-week break and then received either a 120-Gy 125 I or a 90-Gy 103 Pd implant. Until November 1994, all patients underwent an 125 I implant after which the isotope selection was based on either Gleason score (Gleason score 2-5: 125 I; Gleason 5-8: 103 Pd) or isotope availability. A matched pair analysis was performed to assess any difference between isotopes. Two hundred twenty-two patients were matched according to Gleason score, prostate-specific antigen (PSA), and stage. PSA relapse-free survival (PSA-RFS) was calculated based on the American Society for Therapeutic Radiology and Oncology (ASTRO) Consensus Group definition of failure. Kaplan-Meier actuarial survival curves were compared to assess differences in

  10. Medical physics aspects of ophthalmic brachytherapy

    International Nuclear Information System (INIS)

    Sharma, S.D.; Shanta, A.; Palani Selvam, T.; Tripathi, U.B.; Bhatt, B.C.

    2004-11-01

    Intraocular melanoma is the most common primary malignancy of the eye. Radiation therapy using ophthalmic plaque has proved successful in the management of various ocular lesions. Although a few centres were using 90 Sr/ 90 Y plaques for shallow turtlours some years ago, eye plaque therapy was not a common practice in India. A revived interest in the use of eye plaque therapy and very high cost of imported sources has led to the development and production of 125 I seed sources by the Radiopharmaceuticals Division, BARC. This report presents a brief description on the clinical, dosimetry and radiation safety aspects of 90 Sr/ 90 Y and 106 Ru/ 106 Rh beta ray and 125 I gamma ray eye plaque applicators. This report has been divided in five Sections. Section I presents general introduction of ophthalmic brachytherapy including the structure of a human eye, types of ophthalmic plaques and characteristics of radioisotopes commonly used in such applications. A brief review of sources, applicators and dosimetry of 90 Sr/ 90 Y and 106 Ru/ 106 Rh beta and 125 I gamma ophthalmic plaques are given in Section II and Section III, respectively. Section IV contains the single seed dosimetry data of BARC OcuProsta 125 I seed as well as dosimetry data of typical eye plaques loaded with BARC OcuProsta 125 I seed. Quality assurance and radiation safety aspects of these eye applicators are described in Section V. A proforma of the application required to be filled in by the user institution for obtaining regulatory consent to start eye plaque therapy has also been appended to this report. (author)

  11. A therapeutic gain model for brachytherapy

    International Nuclear Information System (INIS)

    Wigg, D.R.

    2003-01-01

    When treating with continuous irradiation the potential therapeutic gain or loss depends on several treatment, normal tissue and tumour variables. There are similarities between equations defining tissue effects with fractionated treatment and brachytherapy. The former is sensitive to dose per fraction (and incomplete repair for short intervals between treatments) and the later is sensitive to dose rate and continuous repair factors. Because of these similarities, for typical tumours and normal tissues, dose per fraction and dose rates generally work in similar directions. As the dose per fraction or dose rate increases the therapeutic gain falls. With continuous irradiation the dose rates effects are determined by Beta cell kill and hence the absolute value of Beta . Minimal sensitivity occurs at very low and very high dose rates. The magnitude of cell kill also depends on the Continuous Repair Factor (g) which is a function of the treatment time and the Repair Half Time (in hours) of the tissues (Repair Half Time T 1/2Ln(2)/h, when h the Repair Constant). An interactive optimising model has been written to predict the therapeutic gain or loss as the parameter values are varied. This model includes the tumour and normal tissue parameters alpha and beta Gy (or individual values), their Repair Half Times, dose rates and overall treatment time. The model is based on the Linear-Quadratic equation and the Total Effect (TE) method of Thames and Hendry although the Extrapolated Response Dose (ERD) method of Barendsen produces the same results. The model is written so that the gain or loss may be seen when treatment is always to normal tissue tolerance doses. The magnitude of the therapeutic loss as the dose rate increases and its sensitivity to changes in normal tissue and tumour parameter values is clearly demonstrated

  12. Brachytherapy dose measurements in heterogeneous tissues

    International Nuclear Information System (INIS)

    Paiva F, G.; Luvizotto, J.; Salles C, T.; Guimaraes A, P. C.; Dalledone S, P. de T.; Yoriyaz, H.; Rubo, R.

    2014-08-01

    Recently, Beau lieu et al. published an article providing guidance for Model-Based Dose Calculation Algorithms (MBDCAs), where tissue heterogeneity considerations are addressed. It is well-known that T G-43 formalism which considers only water medium is limited and significant dose differences have been found comparing both methodologies. The aim of the present work is to experimentally quantify dose values in heterogeneous medium using different dose measurement methods and techniques and compare them with those obtained with Monte Carlo simulations. Experiments have been performed using a Nucletron micro Selectron-Hdr Ir-192 brachytherapy source and a heterogeneous phantom composed by PMMA and different tissue equivalent cylinders like bone, lungs and muscle. Several dose measurements were obtained using tissue equivalent materials with height 1.8 cm and 4.3 cm positioned between the radiation source and the detectors. Radiochromic films, TLDs and MOSFET S have been used for the dose measurements. Film dosimetry has been performed using two methodologies: a) linearization for dose-response curve based on calibration curves to create a functional form that linearize s the dose response and b) 177 multichannel analysis dosimetry where the multiple color channels are analyzed allowing to address not only disturbances in the measurements caused by thickness variation in the film layer, but also, separate other external influences in the film response. All experiments have been simulated using the MCNP5 Monte Carlo radiation transport code. Comparison of experimental results are in good agreement with calculated dose values with differences less than 6% for almost all cases. (Author)

  13. Brachytherapy dose measurements in heterogeneous tissues

    Energy Technology Data Exchange (ETDEWEB)

    Paiva F, G.; Luvizotto, J.; Salles C, T.; Guimaraes A, P. C.; Dalledone S, P. de T.; Yoriyaz, H. [Instituto de Pesquisas Energeticas e Nucleares / CNEN, Av. Lineu Prestes 2242, Cidade Universitaria, 05508-000 Sao Paulo (Brazil); Rubo, R., E-mail: gabrielpaivafonseca@gmail.com [Hospital das Clinicas da Faculdade de Medicina da Universidade de Sao Paulo, 05403-900 Sao Paulo (Brazil)

    2014-08-15

    Recently, Beau lieu et al. published an article providing guidance for Model-Based Dose Calculation Algorithms (MBDCAs), where tissue heterogeneity considerations are addressed. It is well-known that T G-43 formalism which considers only water medium is limited and significant dose differences have been found comparing both methodologies. The aim of the present work is to experimentally quantify dose values in heterogeneous medium using different dose measurement methods and techniques and compare them with those obtained with Monte Carlo simulations. Experiments have been performed using a Nucletron micro Selectron-Hdr Ir-192 brachytherapy source and a heterogeneous phantom composed by PMMA and different tissue equivalent cylinders like bone, lungs and muscle. Several dose measurements were obtained using tissue equivalent materials with height 1.8 cm and 4.3 cm positioned between the radiation source and the detectors. Radiochromic films, TLDs and MOSFET S have been used for the dose measurements. Film dosimetry has been performed using two methodologies: a) linearization for dose-response curve based on calibration curves to create a functional form that linearize s the dose response and b) 177 multichannel analysis dosimetry where the multiple color channels are analyzed allowing to address not only disturbances in the measurements caused by thickness variation in the film layer, but also, separate other external influences in the film response. All experiments have been simulated using the MCNP5 Monte Carlo radiation transport code. Comparison of experimental results are in good agreement with calculated dose values with differences less than 6% for almost all cases. (Author)

  14. Patient effective dose from endovascular brachytherapy with 192Ir Sources

    International Nuclear Information System (INIS)

    Perna, L.; Bianchi, C.; Novario, R.; Nicolini, G.; Tanzi, F.; Conte, L.

    2002-01-01

    The growing use of endovascular brachytherapy has been accompanied by the publication of a large number of studies in several fields, but few studies on patient dose have been found in the literature. Moreover, these studies were carried out on the basis of Monte Carlo simulation. The aim of the present study was to estimate the effective dose to the patient undergoing endovascular brachytherapy treatment with 192 Ir sources, by means of experimental measurements. Two standard treatments were taken into account: an endovascular brachytherapy of the coronary artery corresponding to the activity x time product of 184 GBq.min and an endovascular brachytherapy of the renal artery (898 GBq.min). Experimental assessment was accomplished by thermoluminescence dosemeters positioned in more than 300 measurement points in a properly adapted Rando phantom. A method has been developed to estimate the mean organ doses for all tissues and organs concerned in order to calculate the effective dose associated with intravascular brachytherapy. The normalised organ doses resulting from coronary treatment were 2.4x10 -2 mSv.GBq -1 .min -1 for lung, 0.9x10 -2 mSv.GBq -1 .min -1 for oesophagus and 0.48x10 -2 mSv.GBq -1 .min -1 for bone marrow. During brachytherapy of the renal artery, the corresponding normalised doses were 4.2x10 -2 mSv.GBq -1 .min -1 for colon, 7.8x10 -2 mSv.GBq -1 .min -1 for stomach and 1.7x10 -2 mSv.GBq -1 .min -1 for liver. Coronary treatment involved an effective dose of 0.046 mSv.GBq -1 .min -1 , whereas the treatment of the renal artery resulted in an effective dose of 0.15 mSv.GBq -1 .min -1 ; there were many similarities with data from former studies. Based on these results it can be concluded that the dose level of patients exposed during brachytherapy treatment is low. (author)

  15. Comparative dosimetry in intracavitary balloon catheter brachytherapy with I-125 and in Cf-252 brachytherapy combined with BNCT for brain tumors

    Energy Technology Data Exchange (ETDEWEB)

    Brandao, Samia de Freitas, E-mail: samiabrandao@gmail.com [Universidade Federal de Minas Gerais (UFMG), Belo Horizonte, MG (Brazil). Departamento de Engenharia Nuclear; Campos, Tarcisio Passos Ribeiro de [Universidade Federal de Minas Gerais (UFMG), Belo Horizonte, MG (Brazil)

    2013-06-15

    Objective: comparative analysis of dosimetry in intracavitary balloon catheter brachytherapy with I-125 and in Cf-252 brachytherapy combined with BNCT for treatment of brain tumors. Materials and methods: simulations of intracavitary balloon catheter brachytherapy with I-125 and in Cf-252 brachytherapy combined with BNCT were performed with the MCNP5 code, modeling the treatment of a brain tumor on a voxel computational phantom representing a human head. Absorbed dose rates were converted into biologically weighted dose rates. Results: intracavitary balloon catheter brachytherapy with I-125 produced biologically weighted mean dose rates of 3.2E-11, 1.3E-10, 1.9E-11 and 6.9E-13 RBE.Gy.h{sup -1}.p{sup -1}.s, respectively, on the healthy tissue, on the balloon periphery and on the /{sub 1} and /{sub 2} tumor infiltration zones. On the other hand, Cf-252 brachytherapy combined with BNCT produced a biologically weighted mean dose rate of 5.2E-09, 2.3E-07, 8.7E-09 and 2.4E-09 RBE.Gy.h{sup -1}.p{sup -1}.s, respectively on the healthy tissue, on the target tumor and on the /{sub 1} and /{sub 2} infiltration zones. Conclusion: Cf-252 brachytherapy combined with BNCT delivered a selective irradiation to the target tumor and to infiltration zones, while intracavitary balloon catheter brachytherapy with I-125 delivered negligible doses on the tumor infiltration zones. (author)

  16. Comparative dosimetry in intracavitary balloon catheter brachytherapy with I-125 and in Cf-252 brachytherapy combined with BNCT for brain tumors

    Directory of Open Access Journals (Sweden)

    Samia de Freitas Brandao

    2013-07-01

    Full Text Available Objective Comparative analysis of dosimetry in intracavitary balloon catheter brachytherapy with I-125 and in Cf-252 brachytherapy combined with BNCT for treatment of brain tumors. Materials and Methods Simulations of intracavitary balloon catheter brachytherapy with I-125 and in Cf-252 brachytherapy combined with BNCT were performed with the MCNP5 code, modeling the treatment of a brain tumor on a voxel computational phantom representing a human head. Absorbed dose rates were converted into biologically weighted dose rates. Results Intracavitary balloon catheter brachytherapy with I-125 produced biologically weighted mean dose rates of 3.2E-11, 1.3E-10, 1.9E-11 and 6.9E-13 RBE.Gy.h-1.p-1.s, respectively, on the healthy tissue, on the balloon periphery and on the I 1 and I 2 tumor infiltration zones. On the other hand, Cf-252 brachytherapy combined with BNCT produced a biologically weighted mean dose rate of 5.2E-09, 2.3E-07, 8.7E-09 and 2.4E-09 RBE.Gy.h-1.p-1.s, respectively on the healthy tissue, on the target tumor and on the I 1 and I 2 infiltration zones. Conclusion Cf-252 brachytherapy combined with BNCT delivered a selective irradiation to the target tumor and to infiltration zones, while intracavitary balloon catheter brachytherapy with I-125 delivered negligible doses on the tumor infiltration zones.

  17. Inverse planning and class solutions for brachytherapy treatment planning

    International Nuclear Information System (INIS)

    Trnkova, P.

    2010-01-01

    Brachytherapy or interventional radiooncology is a method of radiation therapy. It is a method, where a small encapsulated radioactive source is placed near to / in the tumour and therefore delivers high doses directly to the target volume. Organs at risk (OARs) are spared due to the inverse square dose fall-off. In the past years there was a slight stagnation in the development of techniques for brachytherapy treatment. While external beam radiotherapy became more and more sophisticated, in brachytherapy traditional methods have been still used. Recently, 3D imaging was considered also as the modality for brachytherapy and more precise brachytherapy could expand. Nowadays, an image guided brachytherapy is state-of-art in many centres. Integration of imaging methods lead to the dose distribution individually tailored for each patient. Treatment plan optimization is mostly performed manually as an adaptation of a standard loading pattern. Recently, inverse planning approaches have been introduced into brachytherapy. The aim of this doctoral thesis was to analyze inverse planning and to develop concepts how to integrate inverse planning into cervical cancer brachytherapy. First part of the thesis analyzes the Hybrid Inverse treatment Planning and Optimization (HIPO) algorithm and proposes a workflow how to safely work with this algorithm. The problem of inverse planning generally is that only the dose and volume parameters are taken into account and spatial dose distribution is neglected. This fact can lead to unwanted high dose regions in a normal tissue. A unique implementation of HIPO into the treatment planning system using additional features enabled to create treatment plans similar to the plans resulting from manual optimization and to shape the high dose regions inside the CTV. In the second part the HIPO algorithm is compared to the Inverse Planning Simulated Annealing (IPSA) algorithm. IPSA is implemented into the commercial treatment planning system. It

  18. Gadolinium neutron capture brachytherapy (GdNCB), a new treatment method for intravascular brachytherapy

    International Nuclear Information System (INIS)

    Enger, Shirin A.; Rezaei, Arash; Munck af Rosenschoeld, Per; Lundqvist, Hans

    2006-01-01

    Restenosis is a major problem after balloon angioplasty and stent implantation. The aim of this study is to introduce gadolinium neutron capture brachytherapy (GdNCB) as a suitable modality for treatment of stenosis. The utility of GdNCB in intravascular brachytherapy (IVBT) of stent stenosis is investigated by using the GEANT4 and MCNP4B Monte Carlo radiation transport codes. To study capture rate, Kerma, absorbed dose and absorbed dose rate around a Gd-containing stent activated with neutrons, a 30 mm long, 5 mm diameter gadolinium foil is chosen. The input data is a neutron spectrum used for clinical neutron capture therapy in Studsvik, Sweden. Thermal neutron capture in gadolinium yields a spectrum of high-energy gamma photons, which due to the build-up effect gives an almost flat dose delivery pattern to the first 4 mm around the stent. The absorbed dose rate is 1.33 Gy/min, 0.25 mm from the stent surface while the dose to normal tissue is in order of 0.22 Gy/min, i.e., a factor of 6 lower. To spare normal tissue further fractionation of the dose is also possible. The capture rate is relatively high at both ends of the foil. The dose distribution from gamma and charge particle radiation at the edges and inside the stent contributes to a nonuniform dose distribution. This will lead to higher doses to the surrounding tissue and may prevent stent edge and in-stent restenosis. The position of the stent can be verified and corrected by the treatment plan prior to activation. Activation of the stent by an external neutron field can be performed days after catherization when the target cells start to proliferate and can be expected to be more radiation sensitive. Another advantage of the nonradioactive gadolinium stent is the possibility to avoid radiation hazard to personnel

  19. Role of TPS in 125I brachytherapy for orbital tumors

    International Nuclear Information System (INIS)

    Ren Ling; Dai Haojie; Li Quan

    2012-01-01

    Objective: To investigate the role of TPS in 125 I brachytherapy for orbital tumors. Methods: Sixty-six patients with orbital tumor treated with 125 I seeds from 2005 to 2009 were retrospectively analyzed. Forty-three patients were treated using TPS guided brachytherapy and the prescribed dose was 140 Gy. Other 23 patients were treated without TPS but simply implanted with 125 I seeds at 1 cm intervals in parallel with each other intraoperatively. CT and TPS quality verification were performed postoperatively in all patients. Also, CT and (or) MRI examination were performed at 3, 6, 12 and 24 months after brachytherapy for follow-up. χ 2 test and Kaplan-Meier survival analysis with log-rank significance test were used with SPSS 17.0. Results: A total of 1070 125 I seeds were implanted in 66 cases, on average, (16.2 ± 7.3) seeds for each patient. The satisfaction rates of postoperative quality verification in patients with and without TPS pre-plans were 79.07% (34/43) and 43.48% (10/23) respectively (χ 2 =8.542, P=0.003). Ten patients were lost in follow-up. Local recurrence rates in patients with favorable postoperative quality verification were 0 (0/37) in 3 months, 6.25% (2/32) in 6 months, 13.64% (3/22) in 12 months and 3/9 in 24 months respectively, which were significantly different from those (5.26% (1/19), 16.67% (3/18), 30.77% (4/13), 6/6) in the patients with inferior postoperative quality verification (χ 2 =9.017, P=0.0003). Conclusions: TPS plays an important role in 125 I brachytherapy for orbital tumors. Also, postoperative quality verification by TPS may help predict the local recurrence after brachytherapy. (authors)

  20. Results of the intestitial brachytherapy and of the combination external radiation-brachytherapy in 150 patients with carcinoma of the oral tongue and floor of the mouth

    International Nuclear Information System (INIS)

    Sannazzari, G.L.; Negri, G.L.; Ozzello, F.

    1986-01-01

    The authors report their experience on the treatment of carcinoma of the oral tongue and floor of the mouth with interstitial brachytherapy, alone or in conbination with external irradiation. One hundred and fifty patients were treated; among these, 116 with brachytherapy alone, 34 with combined treatment. The five years local control in those patients treated with brachytherapy alone was 72.5% in T1, 61.2% in T2 and 35% in T3; in those patients treated with external irradiation and brachytherapy the global five years control was 42.5%. The global five years survival was 64% in the patients treated with brachytherapy alone 48% in the patients treated with combined therapy

  1. Results of the intestitial brachytherapy and of the combination external radiation-brachytherapy in 150 patients with carcinoma of the oral tongue and floor of the mouth

    Energy Technology Data Exchange (ETDEWEB)

    Sannazzari, G L; Negri, G L; Ozzello, F

    1986-01-01

    The authors report their experience on the treatment of carcinoma of the oral tongue and floor of the mouth with interstitial brachytherapy, alone or in conbination with external irradiation. One hundred and fifty patients were treated; among these, 116 with brachytherapy alone, 34 with combined treatment. The five years local control in those patients treated with brachytherapy alone was 72.5% in T1, 61.2% in T2 and 35% in T3; in those patients treated with external irradiation and brachytherapy the global five years control was 42.5%. The global five years survival was 64% in the patients treated with brachytherapy alone 48% in the patients treated with combined therapy. 42 refs.

  2. Brachytherapy in head and neck cancers; Curietherapie des cancers de la sphere ORL

    Energy Technology Data Exchange (ETDEWEB)

    Mazeron, J.J.; Noel, G.; Simon, J.M.; Racadot, S.; Jauffret, E. [Groupe Hospitalier la Pitie-Salpetriere, Centre des Tumeurs, 75 - Paris (France)

    2003-02-01

    Experience accumulated over several decades with radiation of Head and Neck tumours by irradiation has demonstrated the need for a high tumour dose to achieve local control. With external beam irradiation alone, it is difficult to spare adjacent normal tissues, resulting in undesirable late effects on the salivary glands; mandible, and muscles of mastication. Interstitial implantation is ideally suited to deliver a high dose limited to the volume of the primary tumor, thus minimizing sequels. A large experience has been accumulated with low dose rate (LDR) brachytherapy in treatment of carcinoma of oral cavity, oropharynx, and nasopharynx. Recent analysis of large clinical series provided data indicating that modalities of low dose rate brachytherapy should be optimized in treating these tumors for increasing therapeutic ratio. Low dose rate brachytherapy is now challenged by high dose rate (HDR) brachytherapy and pulsed dose rate (PDR) brachytherapy. Preliminary results obtained with these two last modalities are discussed regarding to those of low dose rate brachytherapy. (authors)

  3. O ecologismo dos pobres

    OpenAIRE

    ALIER, Juan Martinez

    1997-01-01

    O ecologísmo tem colocado em cheque as leis capitalistas de mercado, principalmente na sua fase globalizada, devido à apropriação e exploração inconsequente dos recursos naturais. Ao mesmo tempo tem apontado que o meio ambiente não se reduz ao tratamento somente cientifico da natureza. O presente artigo ressalta aspectos importantes do ecologísmo como a participação das mulheres, o marxismo, o neo-narodnismo, etc. e é rico em exemplos de problemas ambientais decorrentes das relações de produç...

  4. Dos novelas colombianas olvidadas

    Directory of Open Access Journals (Sweden)

    Eduardo García Piedrahita

    1980-06-01

    Full Text Available Estas dos novelas olvidadas llevan por títulos Pax de don Lorenzo Marroquín (pr. edi. 1907, y Diana Cazadora de don Clímaco Soto Borda(pr. edi. 1917, ambos bogotanos aunque de disímiles estirpes literarias; y como tales en sus obras fluyen física y verbalmente, el ambiente de su ciudad natal; espíritu hecho de zumbona crítica, individualismo cáustico y solapada parodia de usos y costumbres. Y sobre tales bases sentimentales y estilísticas debe considerárselas.

  5. Geoeconomia dos emergentes

    OpenAIRE

    Pinto, Pedro

    2010-01-01

    Mercados decisivos para a recuperação da economia global, até porque muito mais imunes às consequências da crise fi nanceira, os países emergentes apresentam taxas de crescimento mais altas face aos principais países desenvolvidos e têm desempenhado um papel fundamental na consolidação dos volumes de comércio internacional e de crescimento da economia mundial ao longo desta última década.

  6. Dos cupas complutenses

    Directory of Open Access Journals (Sweden)

    Stylow, Armin U.

    2006-12-01

    Full Text Available Publication of two cupae from the ancient territory of Complutum. One was found in excavations in Alcalá de Henares (Madrid and is unpublished; of the other one, which came to light in the church of Alovera (Guadalajara, a new reading is given.Se publican dos cupas del antiguo territorio de Complutum, una, inédita, encontrada en excavación en Alcalá de Henares (Madrid, y la segunda, procedente de la iglesia de Alovera (Guadalajara, con una nueva lectura.

  7. CAPITAL HUMANO: DOS ENFOQUES

    Directory of Open Access Journals (Sweden)

    María Isabel Pueyo Roy

    2005-01-01

    Full Text Available El artículo presenta un resumen de la teoría existente sobre capital humano, considerando dos proposiciones que se complementan: la Teoría Neoclásica -educación como formación laboral o señalización al mercado de trabajo- y la Teoría Institucional o de mercados internos de trabajo. Se presenta el desarrollo de ambas teorías, los problemas que presentan y la complementariedad entre las mismas.

  8. Utilization of prostate brachytherapy for low risk prostate cancer: Is the decline overstated?

    OpenAIRE

    Joseph Safdieh; Andrew Wong; Joseph P. Weiner; David Schwartz; David Schreiber

    2016-01-01

    Purpose : Several prior studies have suggested that brachytherapy utilization has markedly decreased, coinciding with the recent increased utilization of intensity modulated radiation therapy, as well as an increase in urologist-owned centers. We sought to investigate the brachytherapy utilization in a large, hospital-based registry. Material and methods: Men with prostate cancer diagnosed between 2004-2012 and treated with either external beam radiation and/or prostate brachytherapy ...

  9. Toward a 'all high rate' brachytherapy: organisation, biology and perspectives after treatment of 192 patients

    International Nuclear Information System (INIS)

    Hannoun-Levi, J.M.; Ferre, M.; Gautier, M.; Marcie, S.

    2007-01-01

    As a result of radiation protection regulations aimed at reducing the exposure to ionizing radiation from care-givers, low dose rate brachytherapy is usually replaced by a pulsed rate brachytherapy. The center Antoine Lacassagne has directed the outset to the use of a high-dose rate brachytherapy. The implications in terms of organization, biology and the prospects for such a change are the principal questions studied. (N.C.)

  10. Calculated and measured brachytherapy dosimetry parameters in water for the Xoft Axxent X-Ray Source: An electronic brachytherapy source

    International Nuclear Information System (INIS)

    Rivard, Mark J.; Davis, Stephen D.; DeWerd, Larry A.; Rusch, Thomas W.; Axelrod, Steve

    2006-01-01

    A new x-ray source, the model S700 Axxent trade mark sign X-Ray Source (Source), has been developed by Xoft Inc. for electronic brachytherapy. Unlike brachytherapy sources containing radionuclides, this Source may be turned on and off at will and may be operated at variable currents and voltages to change the dose rate and penetration properties. The in-water dosimetry parameters for this electronic brachytherapy source have been determined from measurements and calculations at 40, 45, and 50 kV settings. Monte Carlo simulations of radiation transport utilized the MCNP5 code and the EPDL97-based mcplib04 cross-section library. Inter-tube consistency was assessed for 20 different Sources, measured with a PTW 34013 ionization chamber. As the Source is intended to be used for a maximum of ten treatment fractions, tube stability was also assessed. Photon spectra were measured using a high-purity germanium (HPGe) detector, and calculated using MCNP. Parameters used in the two-dimensional (2D) brachytherapy dosimetry formalism were determined. While the Source was characterized as a point due to the small anode size, P (5) were 0.20, 0.24, and 0.29 for the 40, 45, and 50 kV voltage settings, respectively. For 1 125 I and 103 Pd, yet with capability for variable and much higher dose rates and subsequently adjustable penetration capabilities. This paper presents the calculated and measured in-water brachytherapy dosimetry parameters for the model S700 Source at the aforementioned three operating voltages

  11. Advantages of high-dose rate (HDR) brachytherapy in treatment of prostate cancer

    Science.gov (United States)

    Molokov, A. A.; Vanina, E. A.; Tseluyko, S. S.

    2017-09-01

    One of the modern methods of preserving organs radiation treatment is brachytherapy. This article analyzes the results of prostate brachytherapy. These studies of the advantages of high dose brachytherapy lead to the conclusion that this method of radiation treatment for prostate cancer has a favorable advantage in comparison with remote sensing methods, and is competitive, preserving organs in comparison to surgical methods of treatment. The use of the method of polyfocal transperineal biopsy during the brachytherapy session provides information on the volumetric spread of prostate cancer and adjust the dosimetry plan taking into account the obtained data.

  12. Image guided, adaptive, accelerated, high dose brachytherapy as model for advanced small volume radiotherapy

    International Nuclear Information System (INIS)

    Haie-Meder, Christine; Siebert, Frank-Andre; Poetter, Richard

    2011-01-01

    Brachytherapy has consistently provided a very conformal radiation therapy modality. Over the last two decades this has been associated with significant improvements in imaging for brachytherapy applications (prostate, gynecology), resulting in many positive advances in treatment planning, application techniques and clinical outcome. This is emphasized by the increased use of brachytherapy in Europe with gynecology as continuous basis and prostate and breast as more recently growing fields. Image guidance enables exact knowledge of the applicator together with improved visualization of tumor and target volumes as well as of organs at risk providing the basis for very individualized 3D and 4D treatment planning. In this commentary the most important recent developments in prostate, gynecological and breast brachytherapy are reviewed, with a focus on European recent and current research aiming at the definition of areas for important future research. Moreover the positive impact of GEC-ESTRO recommendations and the highlights of brachytherapy physics are discussed what altogether presents a full overview of modern image guided brachytherapy. An overview is finally provided on past and current international brachytherapy publications focusing on 'Radiotherapy and Oncology'. These data show tremendous increase in almost all research areas over the last three decades strongly influenced recently by translational research in regard to imaging and technology. In order to provide high level clinical evidence for future brachytherapy practice the strong need for comprehensive prospective clinical research addressing brachytherapy issues is high-lighted.

  13. El ajuste o desajuste de las prácticas normativas en Ignacio Ellacuría: hacia una nueva dimensión de lo normativo /

    Directory of Open Access Journals (Sweden)

    Senent, Juan Antonio

    2011-08-01

    Full Text Available Abstract: This work provides an analysis of adjustment or disadjustment of human rights from Ignacio Ellacuría thesis. We must first place this analysis in the critical context that animatesit, the horizon of historical praxis. From there, a rationale for its adjustment in relation to human praxis is proposed, as well as a critical study of the role such adjustment or maladjustment of regulatory schemes currently plays in the overall regulatory process within the social practices in the contemporary civilization stage.In turn, we conduct an analysis of the struggle to articulate other regulatory schemes that respond more tightly to the demands of justiceagainst others and nature.Resumo: Este trabajo realiza un análisis sobre el ajuste o desajuste de los derechos humanos a partir de la tesis de Ignacio Ellacuría. Se trata primero de ubicar este análisis en el contexto crítico que lo anima, el horizonte de la praxis histórica. Desde ahí se propone una fundamentación del ajuste en su relación con la praxis humana, así como el estudio crítico del papel que ese ajuste o desajuste de los esquemas normativos juega actualmente en el conjunto del procesonormativo en el seno de las prácticas sociales en la presente fase civilizatoria. A su vez, se aborda un análisis de la lucha por articular otros esquemas normativos que respondan más ajustadamentea las exigencias de la justicia frente a los otros y a la naturaleza.

  14. dos estudios de caso

    Directory of Open Access Journals (Sweden)

    Daniel Kersffeld

    2013-01-01

    Full Text Available La UNASUR se ha destacado desde sus inicios en la compleja labor de mediación y resolución de conflictos internacionales. Para ello, esta entidad multilateral ha apelado a distintas fórmulas políticas tendientes al encausamiento de problemáticas y conflictos apartados del camino de la institucionalidad y de los medios tradicionales de resolución. Con todo, y pese a la búsqueda de caminos alternativos, han sido las cumbres presidenciales la principal herramienta destinada a encontrar soluciones innovadoras y respetuosas del orden democrático y constitucional de los países sudamericanos. En este artículo se analiza de manera específica la actuación de la unasur en dos casos de profunda gravedad institucional: el intento de golpe de Estado ocurrido en Ecuador el 30 de septiembre de 2010 y el derrocamiento del ex presidente Fernando Lugo en Paraguay en junio de 2012. Luego de analizar estos dos casos extremos, y las implicancias políticas generadas, se avanza en una visión comprensiva acerca del éxito o el fracaso del papel político de la unasur como instancia de resolución de conflictos a nivel internacional.

  15. dose in cervical cancer intracavitary brachytherapy

    Directory of Open Access Journals (Sweden)

    Zahra Siavashpour

    2016-04-01

    Full Text Available Purpose: To analyze the optimum organ filling point for organs at risk (OARs dose in cervical cancer high-dose-rate (HDR brachytherapy. Material and methods : In a retrospective study, 32 locally advanced cervical cancer patients (97 insertions who were treated with 3D conformal external beam radiation therapy (EBRT and concurrent chemotherapy during 2010-2013 were included. Rotterdam HDR tandem-ovoid applicators were used and computed tomography (CT scanning was performed after each insertion. The OARs delineation and GEC-ESTRO-based clinical target volumes (CTVs contouring was followed by 3D forward planning. Then, dose volume histogram (DVH parameters of organs were recorded and patients were classified based on their OARs volumes, as well as their inserted tandem length. Results : The absorbed dose to point A ranged between 6.5-7.5 Gy. D 0.1cm ³ and D 2cm ³ of the bladder significantly increased with the bladder volume enlargement (p value < 0.05. By increasing the bladder volume up to about 140 cm3, the rectum dose was also increased. For the cases with bladder volumes higher than 140 cm3, the rectum dose decreased. For bladder volumes lower than 75 cm3, the sigmoid dose decreased; however, for bladder volumes higher than 75 cm3, the sigmoid dose increased. The D 2cm ³ of the bladder and rectum were higher for longer tandems than for shorter ones, respectively. The divergence of the obtained results for different tandem lengths became wider by the extension of the bladder volume. The rectum and sigmoid volume had a direct impact on increasing their D 0.1cm ³ and D 2cm ³, as well as decreasing their D 10 , D 30 , and D 50 . Conclusions : There is a relationship between the volumes of OARs and their received doses. Selecting a bladder with a volume of about 70 cm3 or less proved to be better with regards to the dose to the bladder, rectum, and sigmoid.

  16. Brachytherapy radiation doses to the neurovascular bundles

    International Nuclear Information System (INIS)

    Di Biase, Steven J.; Wallner, Kent; Tralins, Kevin; Sutlief, Steven

    2000-01-01

    Purpose: To investigate the role of radiation dose to the neurovascular bundles (NVB) in brachytherapy-related impotence. Methods and Materials: Fourteen Pd-103 or I-125 implant patients were studied. For patients treated with implant alone, the prostate and margin (clinical target volume [CTV]) received a prescription dose of 144 Gy for I-125 or 115 Gy for Pd-103. Two patients received Pd-103 (90 Gy) with 46 Gy supplemental external beam radiation (EBRT). Axial CT images were acquired 2 to 4 hours postoperatively for postimplant dosimetry. Because the NVBs cannot be visualized on CT, NVB calculation points were determined according to previously published anatomic descriptions. Bilateral NVB points were considered to lie posterior-laterally, approximately 2 mm from the prostatic capsule. NVB doses were recorded bilaterally, at 0.5-cm intervals from the prostatic base. Results: For Pd-103, the average NVB doses ranged from 150 Gy to 260 Gy, or 130% to 226% of the prescription dose. For I-125, the average NVB dose ranged from 200 Gy to 325 Gy, or 140% to 225% of the prescription dose. These was no consistent relationship between the NVB dose and the distance from the prostatic base. To examine the possible effect of minor deviations of our calculation points from the true NVB location, we performed NVB calculations at points 2 mm medial or lateral from the NVB calculation point in 8 patients. Doses at these alternate calculation points were comparable, although there was greater variability with small changes in the calculation point if sources were located outside the capsule, near the NVB calculation point. Three patients who developed early postimplant impotence had maximal NVB doses that far exceeded the average values. Conclusions: In the next few years, we hope to clarify the role of high NVB radiation doses on potency, by correlating NVB dose calculations with a large number of patients enrolled in an ongoing I-125 versus Pd-103 trial for early-stage patients

  17. Conformational episcleral brachytherapy in ocular tumors

    International Nuclear Information System (INIS)

    Goset, Karen; Barriga, Hernan; Guevara, Juan; Zelada, Gabriel; Badinez, Leonardo; Gonzalez, German

    2000-01-01

    Brachytherapy with an episcleral plate is an alternative treatment for choroid melanomas and retinoblastomas that allows the sight to be saved. The most common techniques use a metal applicator with beta or Co-60 transmitters, which have a standard geometry, require surgical installation of the active devices and do not allow optimized dosimetry. In 1997, the Clinica Alemana in Santiago, Chile, developed a new device based on the one described by J.P. Gerard (1988), with plastic material, personalized and with delayed charge. Three cases have been treated. Two retinoblastomas: 1) Primary treatment in unilateral Rb, R.E. group II in a 9 month old boy, 2) External post radiotherapy rescue in oculus ultimus by bilateral Rb in a 10 year old girl, and 3) Choroid melanoma T3N0M0 in a 77 year old woman. A personalized applicator was prepared in each case depending on the size and location of the tumor. The distribution of the vector catheters was designed following the Paris system standards. The applicator was inserted in the operating room, under general anesthesia by a team of trained ophthalmologists. An X-ray and helichoidal simulation scan were taken with fictitious sources. Previsional dosimetry was undertaken, with evaluation of the dosage to the tumor apex, crystalline lens, sclera and optic nerve. Prolonged activation with low level dosage Ir-192 wires was performed in a protected room. When the programmed dosage was completed, the sources and then the inactive applicator were removed. Dosage: A 40 Gy dose was applied in the retinoblastoma to the tumor apex and 60 Gy to the melanoma, over a 2 to 3 day period. Tolerance was excellent, there were no incidents or acute complications. The retinoblastomas fully regressed in 1 to 2 weeks, with no local relapse or after affects after 2, 4 and 6 months of follow-up. The 3 patients have retained their sight. The development of this technique is feasible and with enough resources, relatively easy to implement. It has

  18. Dosimetric comparison between intensity modulated brachytherapy versus external beam intensity modulated radiotherapy for cervix cancer: a treatment planning study

    International Nuclear Information System (INIS)

    Subramani, V.; Sharma, D.N.; Jothy Basu, K.S.; Rath, G.K.; Gopishankar, N.

    2008-01-01

    To evaluate the dosimetric superiority of intensity modulated brachytherapy (IMBT) based on inverse planning optimization technique with classical brachytherapy optimization and also with external beam intensity modulated radiotherapy planning technique in patients of cervical carcinoma

  19. Creencias y ajuste psicológico de la persona que acompaña al drogodependiente y creencias de éste durante el tratamiento

    OpenAIRE

    José Miguel Martínez González; Humberto Manuel Trujillo Mendoza

    2005-01-01

    El objetivo de esta investigación fue estudiar si las creencias relacionadas con la vivencia del acompañamiento de un familiar en el tratamiento de un drogodependiente, y las del mismo paciente, varían en función de aspectos como el tiempo de abstinencia, el tiempo dedicado al tratamiento, la presencia de patología dual en el drogodependiente, la gravedad de ajuste psicológico del acompañante, los años de evolución de la drogodependencia y el tiempo transcurrido desde que se co...

  20. Acontecimientos vitales estresantes, estilo de afrontamiento y ajuste adolescente: un análisis longitudinal de los efectos de moderación

    OpenAIRE

    Rosa María Estévez Campos; Alfredo Oliva Delgado; Águeda Parra Jiménez

    2012-01-01

    El objetivo principal de este estudio fue analizar la relación entre la vivencia de los acontecimientos vitales estresantes y los problemas de ajuste emocional y comportamental durante la adolescencia, prestando atención al posible efecto moderador del estilo de afrontamiento. La muestra estuvo compuesta por 90 adolescentes que fueron seguidos durante seis años, desde su adolescencia media (15-16 años) hasta la adultez emergente (21-22 años). Completaron cuestionarios sobre su vivencia de aco...

  1. Ajuste do modelo fototérmico de estimativa do desenvolvimento e do índice de área foliar de soja Adjustment of the photothermic model to estimate soybean development and leaf area index

    Directory of Open Access Journals (Sweden)

    Neila T. Toledo

    2010-03-01

    Full Text Available Visou-se neste estudo, realizar o ajuste do modelo de estimativa do desenvolvimento de populações de soja e da variação do índice de área foliar para a variedade IAS 5. Como fonte de variação na velocidade de desenvolvimento, diferentes épocas de plantio foram utilizadas em experimentos nos anos agrícolas de 2004/2005 (três datas e 2005/2006 (quatro datas no IRDeR (Instituto Regional de Desenvolvimento Rural localizado em Augusto Pestana, RS (28º 27' 17" S e 53º 54' 50" W, nos quais foram identificadas as datas em que ocorreram as principais fases do desenvolvimento da cultura da soja, seguindo a Escala Fenológica de Fehr & Caviness e estimados o índice de área foliar em quatro momentos: no final do período de instalação da população vegetal (V6; no início do florescimento (R1; início do enchimento de grãos (R5; e no início da maturação (R7. As variáveis meteorológicas temperaturas mínima e máxima diárias foram coletadas. Após o ajuste dos coeficientes genéticos, o modelo foi formatado no programa Stella 5.0. O modelo de estimativa do desenvolvimento da soja teve desempenho satisfatório, apresentando estimativas precisas para os dados que o determinaram. O modelo de estimativa do índice de área foliar apresentou estimativas satisfatórias.The present study was carried out to adjust the soy population development model and the leaf area index model for the IAS 5 cultivar. Different sowing dates were used in two experiments as source of development variation during 2004/2005 (three dates and 2005/2006 (four dates in the IRDeR (Instituto Regional de Desenvolvimento Rural located in Augusto Pestana, in the State of Rio Grande do Sul (28º 27' 17" S and 53º 54' 50" W. The main crop development phases were identified according to the Feher & Caviness phenological scale, and the leaf area index was determined in four occasions: at the final period of plant population installation (V6; at the beginning of flowering

  2. Dos estudios de casos

    Directory of Open Access Journals (Sweden)

    Hernán Guillermo Salazar Morales

    1989-04-01

    Full Text Available RESUMEN A continuación se presenta dos casos de estudio en donde se puede apreciar a la forma  como se establecen  las relaciones en una organización y lo que una DECISION  puede llegar a incidir en el desarrollo de las operaciones de una empresa. Decisiones basadas en la intuición, o en corazonadas, frecuentemente conducen en dirección equivocada, ocasionando pérdidas en tiempo, personal y dinero. El proceso de toma de decisiones deben ser TAREAS ESTRUCTURADAS que se sustenten con hechos. Su ejecución debe hacerse secuencialmente y cumplir con cada uno de sus pasos. El diseño de los  casos está orientado para que  sirvan como material de aplicación en la asignatura de  taller de planeación.

  3. A sociedade dos vivos

    Directory of Open Access Journals (Sweden)

    Leis Héctor Ricardo

    2003-01-01

    Full Text Available A pergunta: qual é o significado da experiência da morte na sociedade contemporânea? A hipótese: que existe uma faceta sombria e degradante da condição humana, associada à privatização institucional ou "pacificação" da morte que estamos assistindo em nossa época. Muitos teóricos sociais contemporâneos apostam em estratégias como a reflexividade para reconstruir a fragmentação do ser humano, porém essa reconstrução mal poderia vir sem procurar apoio em aspectos chaves da condição humana. Apontar alguns dos déficits da teoria social contemporânea e assinalar alguns caminhos para superar impasses da sociedade contemporânea resume a tentativa deste trabalho.

  4. Trends in the Utilization of Brachytherapy in Cervical Cancer in the United States

    Energy Technology Data Exchange (ETDEWEB)

    Han, Kathy, E-mail: Kathy.Han@rmp.uhn.on.ca [Radiation Medicine Program, Princess Margaret Hospital, University Health Network, Toronto, Ontario (Canada); Milosevic, Michael; Fyles, Anthony [Radiation Medicine Program, Princess Margaret Hospital, University Health Network, Toronto, Ontario (Canada); Pintilie, Melania [Department of Biostatistics, Princess Margaret Hospital, Toronto, Ontario (Canada); Viswanathan, Akila N. [Department of Radiation Oncology, Dana-Farber Cancer Institute/Brigham and Women' s Hospital, Boston, Massachusetts (United States)

    2013-09-01

    Purpose: To determine the trends in brachytherapy use in cervical cancer in the United States and to identify factors and survival benefits associated with brachytherapy treatment. Methods and Materials: Using the Surveillance, Epidemiology, and End Results (SEER) database, we identified 7359 patients with stages IB2-IVA cervical cancer treated with external beam radiation therapy (EBRT) between 1988 and 2009. Propensity score matching was used to adjust for differences between patients who received brachytherapy and those who did not from 2000 onward (after the National Cancer Institute alert recommending concurrent chemotherapy). Results: Sixty-three percent of the 7359 women received brachytherapy in combination with EBRT, and 37% received EBRT alone. The brachytherapy utilization rate has decreased from 83% in 1988 to 58% in 2009 (P<.001), with a sharp decline of 23% in 2003 to 43%. Factors associated with higher odds of brachytherapy use include younger age, married (vs single) patients, earlier years of diagnosis, earlier stage and certain SEER regions. In the propensity score-matched cohort, brachytherapy treatment was associated with higher 4-year cause-specific survival (CSS; 64.3% vs 51.5%, P<.001) and overall survival (OS; 58.2% vs 46.2%, P<.001). Brachytherapy treatment was independently associated with better CSS (hazard ratio [HR], 0.64; 95% confidence interval [CI], 0.57-0.71), and OS (HR 0.66; 95% CI, 0.60 to 0.74). Conclusions: This population-based analysis reveals a concerning decline in brachytherapy utilization and significant geographic disparities in the delivery of brachytherapy in the United States. Brachytherapy use is independently associated with significantly higher CSS and OS and should be implemented in all feasible cases.

  5. Perioperative high dose rate (HDR brachytherapy in unresectable locally advanced pancreatic tumors

    Directory of Open Access Journals (Sweden)

    Brygida Białas

    2011-07-01

    Full Text Available Purpose: The aim of the study was to present an original technique of catheter implantation for perioperative HDR-Ir192 brachytherapy in patients after palliative operations of unresectable locally advanced pancreatic tumors and to estimate the influence of perioperative HDR-Ir192 brachytherapy on pain relief in terminal pancreatic cancer patients. Material and methods: Eight patients with pancreatic tumors located in the head of pancreas underwent palliative operations with the use of HDR-Ir192 brachytherapy. All patients qualified for surgery reported pain of high intensity and had received narcotic painkillers prior to operation. During the last phase of the surgery, the Nucletron® catheters were implanted in patients to prepare them for later perioperative brachytherapy. Since the 6th day after surgery HDR brachytherapy was performed. Before each brachytherapy fraction the location of implants were checked using fluoroscopy. A fractional dose was 5 Gy and a total dose was 20 Gy in the area of radiation. A comparative study of two groups of patients (with and without brachytherapy with stage III pancreatic cancer according to the TNM scale was taken in consideration. Results and Conclusions: The authors claim that the modification of catheter implantation using specially designed cannula, facilitates the process of inserting the catheter into the tumor, shortens the time needed for the procedure, and reduces the risk of complications. Mean survival time was 5.7 months. In the group of performed brachytherapy, the mean survival time was 6.7 months, while in the group of no brachytherapy performed – 4.4 months. In the group of brachytherapy, only one patient increased the dose of painkillers in the last month of his life. Remaining patients took constant doses of medicines. Perioperative HDR-Ir192 brachytherapy could be considered as a practical application of adjuvant therapy for pain relief in patients with an advanced pancreatic cancer.

  6. Routine quality control of high dose rate brachytherapy equipment

    International Nuclear Information System (INIS)

    Guzman Calcina, Carmen S.; Almeida, Adelaide de; Rocha, Jose R. Oliveira

    2001-01-01

    A Quality Assurance program should be installed also for High Dose Rate brachytherapy, in the order to achieve a correct dose administration to the patient and for the safety to those involved directly with the treatment. The work presented here has the following purposes: Analyze the types of equipment tests presented by the official protocols (TG40, TG56 e ARCAL XXX), evaluate the brachytherapy routine tests of protocols from various national and international radiotherapy services and compare the latter with those presented in the official protocols. As a result, we conclude the following: TG56 presents a higher number of tests when compared to the other official protocols and most of the tests presented by the analyzed services are present in TG56. A suggestion for a basic protocol is presented, emphasizing the periodicity and tolerance level of each of the tests. (author)

  7. Brachytherapy: The need for a national metrology lab in Spain

    International Nuclear Information System (INIS)

    Aviles Lucas, P.

    2011-01-01

    Radiotherapy, along with chemotherapy and surgery, is an essential therapeutic technique for treating malignant tumours. Part of the challenge of a suitable radiotherapy treatment lies on the optimisation of the irradiated volume, which must be adapted to the tumour volume as far as possible. Depending on position of the radiation source relative to the patient, the procedure in question could be external radiotherapy, or brachytherapy. In a brachytherapy procedure, relatively small encapsulated radioactive sources are placed close to or in the tumour volume to be treated. This therapeutic treatment has two obvious advantages; on one hand the prescribed dose can be adjusted to the tumour volume, preventing unnecessary exposure of the adjacent healthy tissues, and on the other, it decreases the treatment duration compared to a radiotherapy treatment. (Author) 19 refs.

  8. Ultrasonography-guided cobalt-60 brachytherapy for malignant glioma

    International Nuclear Information System (INIS)

    Sakai, Noboru; Takenaka, Katsunobu; Ueda, Tatsuya

    1989-01-01

    Brachytherapy with cobalt-60 source is reported. In this method it is characterized that the source is inserted interstitially with remote control system by after-loading method via outer catheter (using tandem tube), which was established in the center of residual tumor, using ultrasonography guide with trepanation, or intraoperatively put within the dead space after tumor resection. Six cases of deep-seated and recurrent malignant glioma, were treated with this method. A total dose of 20 to 45 Gy (10 to 15 Gy/day for 2 to 3 days) was delivered to the target. Additionally conventional external irradiation was followed. The effect of cobalt-60 brachytherapy on such tumors were favorable especially for well-circumscribed glioma less than 3 cm on CT scan. (author)

  9. Dose calculation and isodose curves determination in brachytherapy

    International Nuclear Information System (INIS)

    Maranhao, Frederico B.; Lima, Fernando R.A.; Khoury, Helen J.

    2000-01-01

    Brachytherapy is a form of cancer treatment in which small radioactive sources are placed inside of, or close to small tumors, in order to cause tissue necrosis and, consequently, to interrupt the tumor growth process. A very important aspect to the planning of this therapy is the calculation of dose distributions in the tumor and nearby tissues, to avoid the unnecessary irradiation of healthy tissue. The objective of this work is to develop a computer program that will permit treatment planning for brachytherapy at low dose rates, minimizing the possible errors introduced when such calculations are done manually. Results obtained showed good agreement with those from programs such as BRA, which is widely used in medical practice. (author)

  10. Cervical cancer. Application of MR imaging in brachytherapy

    International Nuclear Information System (INIS)

    Ebe, Kazuyu; Matsunaga, Naofumi

    1996-01-01

    For the purpose of application of MRI in arrangement of brachytherapy of cervical cancer, a method was proposed to see the radiation doses in surrounding tissues by superimposing the dose distribution pattern of the radiation source on the MR image. The applicator for the source was filled with water to get its T2-weighted image and was inserted in the patients. The MRI apparatus was Siemens Magnetom Vision (1.5T) with phased array coil. T2-weighted sagittal and coronary images were taken by turbospin echo and HASTE methods. The section thickness was 5 mm. The dose distribution pattern was superimposed on the frontal and lateral images by Siemens Mevaplan to see the doses in surrounding tissues. In 4 patients, it was possible to estimate the radiation dose in the posterior wall of bladder, anterior wall of rectum and urinary duct. The method is promising for arranging brachytherapy of cervical cancer. (K.H.)

  11. Brachytherapy for coronary restenosis: state of art in 2003

    International Nuclear Information System (INIS)

    Latorzeff, I.; Delannes, M.; Latorzeff, I.; Carrie, D.; Alibelli, M.J.; Bonnet, J.; Duthil, P.

    2003-01-01

    Based on therapeutic approach for benign diseases, vascular brachytherapy decreases smooth vascular muscle cells proliferation and multiplication which lead to the formation of the neo-intima. The radioactive positive action affects arterial recoil due to post angioplasty vessel injury. Randomized studies has shown good angiographic results up to 6 months of follow-up, with 50% in-stent restenosis rate decrease and on the analysed segment as well. Decrease on Mace and TLR show statistically significance. Results don't correlate with emitter and beta emitters had been introduced in France recently. Vascular brachytherapy is actually indicated for in-stent restenosis, there is no evidence to perform this treatment for de novo lesion. Geographic miss, source centering, late thrombosis and pullback procedure may interfere with treatment quality. IVUS allows best target volume determination to a higher quality level. Internationals guidelines such as Eva-Gec-Estro recommendations could increase treatment safety and enable development of an optimal technique. (authors)

  12. Brachytherapy for prostate cancer: Comparative characteristics of procedures

    Directory of Open Access Journals (Sweden)

    S. V. Kanaev

    2015-01-01

    Full Text Available The introduction of interstitial radiation sources is the «youngest» of the radical method of treatment of patients with prostate cancer (PC. The high level of efficiency comparable to prostatectomy at a significantly lower rate of complications causes rapid growth of clinical use of brachytherapy (BT. Depending on the radiation source and the mode of administration into the prostate gland are two types BT – high-dose rate (temporary (HDR-BT and low-dose rate (permanent (LDR-BT brachytherapy. At the heart of these two methods are based on a single principle of direct effect of the quantum gamma radiation on the area of interest. However, the differences between the characteristics of isotopes used and technical aspects of the techniques cause the difference in performance and complication rates for expression HDR-BT and LDR-BT.

  13. UNA APROXIMACIÓN TEÓRICA A LA VALORACIÓN DEL DOBLE AJUSTE EN EL DISEÑO DE LA ESTRATEGIA DE RECURSOS HUMANOS

    Directory of Open Access Journals (Sweden)

    García Carbonell, Natalia

    2013-05-01

    Full Text Available Tradicionalmente la literatura ha considerado la necesidad del doble ajuste, vertical y horizontal, de la estrategia de recursos humanos en las organizaciones. Su importancia estratégica ha sido demostrada en buena parte de los estudios empíricos planteados. Sin embargo, la complejidad de este proceso requiere de un análisis más profundo que permita identificar los elementos que lo hacen posible. En el presente trabajo, partiendo de la revisión de la literatura de las perspectivas de investigación en dirección estratégica de recursos humanos y del concepto «fortaleza del sistema de recursos humanos» propuesto por Bowen y Ostroff (2004, discutimos los 3 factores que integran dicho concepto y su relación con el ajuste del sistema. Como consecuencia de ello, definimos 3 proposiciones teóricas que explican la vinculación entre ambas dimensiones y la fortaleza del sistema.

  14. Braquiterapia com rutênio-106 em melanomas uveais - resultados preliminares: experiência uni-institucional Ruthenium-106 brachytherapy for uveal melanomas - preliminary results: a single institutional experience

    Directory of Open Access Journals (Sweden)

    Rodrigo Souza Dias

    2007-04-01

    Full Text Available OBJETIVO: Analisar os resultados preliminares da braquiterapia com rutênio-106 em pacientes portadores de melanomas uveais. MATERIAIS E MÉTODOS: No período de abril de 2002 a julho de 2003, 20 pacientes com diagnóstico de melanoma uveal foram tratados com braquiterapia com rutênio-106. A dose calculada no ápice tumoral variou de 55 Gy a 100 Gy. Pacientes com lesões com altura maior que 5 mm foram submetidos a termoterapia transpupilar concomitante à colocação da placa oftálmica. RESULTADOS: Quanto à localização da lesão, esta se encontrava na coróide em 75% dos casos, na íris em 15% e no corpo ciliar em 10% dos pacientes. Com seguimento mediano de 19 meses, a sobrevida livre de progressão para a braquiterapia e para a associação com a termoterapia transpupilar foi de 69% e 87%, respectivamente. Observou-se redução significante da altura tumoral após o tratamento. Nenhum dos pacientes foi submetido a enucleação. CONCLUSÃO: Nossos resultados preliminares mostram que a braquiterapia com rutênio-106 é uma opção adequada para o tratamento conservador de melanomas uveais em termos de controle local, manutenção do globo ocular e visão útil, com índice aceitável de complicações.OBJECTIVE: To analyze the early response of uveal melanomas in patients treated with ruthenium-106 brachytherapy. MATERIALS AND METHODS: In the period between April 2002 and July 2003, 20 patients diagnosed with uveal melanoma were submitted to ruthenium-106 brachytherapy. The calculated dose delivered at the apex of the tumor ranged between 55 Gy and 100 Gy. Patients with lesions greater than 5 mm were submitted to transpupillary thermotherapy concomitantly with ophthalmic plaque insertion. RESULTS: As regards the lesions site, 75% of the lesions were located in the choroid, 15% in the iris, and the remainder 10% in the ciliary body. In a median 19-month-follow-up, the progression-free survival for brachytherapy was 69%, and 87% for

  15. Photon energy-fluence correction factor in low energy brachytherapy

    International Nuclear Information System (INIS)

    Antunes, Paula C.G.; Yoriyaz, Hélio; Vijande, Javier; Giménez-Alventosa, Vicent; Ballester, Facundo

    2017-01-01

    The AAPM TG-43 brachytherapy dosimetry formalism has become a standard for brachytherapy dosimetry worldwide; it implicitly assumes that charged-particle equilibrium (CPE) exists for the determination of absorbed dose to water at different locations. At the time of relating dose to tissue and dose to water, or vice versa, it is usually assumed that the photon fluence in water and in tissues are practically identical, so that the absorbed dose in the two media can be related by their ratio of mass energy-absorption coefficients. The purpose of this work is to study the influence of photon energy-fluence in different media and to evaluate a proposal for energy-fluence correction factors for the conversion between dose-to-tissue (D tis ) and dose-to-water (D w ). State-of-the art Monte Carlo (MC) calculations are used to score photon fluence differential in energy in water and in various human tissues (muscle, adipose and bone) in two different codes, MCNP and PENELOPE, which in all cases include a realistic modeling of the 125 I low-energy brachytherapy seed in order to benchmark the formalism proposed. A correction is introduced that is based on the ratio of the water-to-tissue photon energy-fluences using the large-cavity theory. In this work, an efficient way to correlate absorbed dose to water and absorbed dose to tissue in brachytherapy calculations at clinically relevant distances for low-energy photon emitting seed is proposed. The energy-fluence based corrections given in this work are able to correlate absorbed dose to tissue and absorbed dose to water with an accuracy better than 0.5% in the most critical cases. (author)

  16. Brachytherapy in Lip Carcinoma: Long-Term Results

    Energy Technology Data Exchange (ETDEWEB)

    Guibert, Mireille, E-mail: mireilleguib@voila.fr [Department of Head and Neck Surgery, Larrey Hospital, Toulouse (France); David, Isabelle [Department of Radiation Oncology, Claudius Regaud Institut, Toulouse (France); Vergez, Sebastien [Department of Head and Neck Surgery, Larrey Hospital, Toulouse (France); Rives, Michel [Department of Radiation Oncology, Claudius Regaud Institut, Toulouse (France); Filleron, Thomas [Department of Epidemiology, Claudius Regaud Institut, Toulouse (France); Bonnet, Jacques; Delannes, Martine [Department of Radiation Oncology, Claudius Regaud Institut, Toulouse (France)

    2011-12-01

    Purpose: The aim of this study was to evaluate the effectiveness of low-dose-rate brachytherapy for local control and relapse-free survival in squamous cell and basal cell carcinomas of the lips. We compared two groups: one with tumors on the skin and the other with tumors on the lip. Patients and methods: All patients had been treated at Claudius Regaud Cancer Centre from 1990 to 2008 for squamous cell or basal cell carcinoma. Low-dose-rate brachytherapy was performed with iridium 192 wires according to the Paris system rules. On average, the dose delivered was 65 Gy. Results: 172 consecutive patients were included in our study; 69 had skin carcinoma (squamous cell or basal cell), and 92 had squamous cell mucosal carcinoma. The average follow-up time was 5.4 years. In the skin cancer group, there were five local recurrences and one lymph node recurrence. In the mucosal cancer group, there were ten local recurrences and five lymph node recurrences. The 8-year relapse-free survival for the entire population was 80%. The 8-year relapse-free survival was 85% for skin carcinoma 75% for mucosal carcinoma, with no significant difference between groups. The functional results were satisfactory for 99% of patients, and the cosmetic results were satisfactory for 92%. Maximal toxicity observed was Grade 2. Conclusions: Low-dose-rate brachytherapy can be used to treat lip carcinomas at Stages T1 and T2 as the only treatment with excellent results for local control and relapse-free survival. The benefits of brachytherapy are also cosmetic and functional, with 91% of patients having no side effects.

  17. Photon energy-fluence correction factor in low energy brachytherapy

    Energy Technology Data Exchange (ETDEWEB)

    Antunes, Paula C.G.; Yoriyaz, Hélio [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil); Vijande, Javier; Giménez-Alventosa, Vicent; Ballester, Facundo, E-mail: pacrisguian@gmail.com [Department of Atomic, Molecular, and Nuclear Physics and Instituto de Física Corpuscular (UV-CSIC), University of Valencia (Spain)

    2017-07-01

    The AAPM TG-43 brachytherapy dosimetry formalism has become a standard for brachytherapy dosimetry worldwide; it implicitly assumes that charged-particle equilibrium (CPE) exists for the determination of absorbed dose to water at different locations. At the time of relating dose to tissue and dose to water, or vice versa, it is usually assumed that the photon fluence in water and in tissues are practically identical, so that the absorbed dose in the two media can be related by their ratio of mass energy-absorption coefficients. The purpose of this work is to study the influence of photon energy-fluence in different media and to evaluate a proposal for energy-fluence correction factors for the conversion between dose-to-tissue (D{sub tis}) and dose-to-water (D{sub w}). State-of-the art Monte Carlo (MC) calculations are used to score photon fluence differential in energy in water and in various human tissues (muscle, adipose and bone) in two different codes, MCNP and PENELOPE, which in all cases include a realistic modeling of the {sup 125}I low-energy brachytherapy seed in order to benchmark the formalism proposed. A correction is introduced that is based on the ratio of the water-to-tissue photon energy-fluences using the large-cavity theory. In this work, an efficient way to correlate absorbed dose to water and absorbed dose to tissue in brachytherapy calculations at clinically relevant distances for low-energy photon emitting seed is proposed. The energy-fluence based corrections given in this work are able to correlate absorbed dose to tissue and absorbed dose to water with an accuracy better than 0.5% in the most critical cases. (author)

  18. Ocular brachytherapy with a holmium-166 irradiator device

    Energy Technology Data Exchange (ETDEWEB)

    Mourao, Arnaldo P. [Centro Federal de Educacao Tecnoloica de Minas Gerais (CEFET-MG), Belo Horizonte, MG (Brazil). Nucleo de Engenharia Hospitalar], e-mail: aprata@des.cefetmg.br; Campos, Tarcisio P.R. [Universidade Federal de Minas Gerais (UFMG), Belo Horizonte, MG (Brazil). Programa de Pos-graduacao em Ciencias e Tecnicas Nucleares], e-mail: campos@nuclear.ufmg.br

    2009-07-01

    The ocular brachytherapy is a method that allows controlling ocular tumors. However, the irradiation of the ocular area in high doses can bring damages mainly to the surrounding healthy tissue, such as lens, retina and bone tissue of the orbital area in growth phase. Brachytherapy in comparison to teletherapy allows a large reduction of the absorbed doses in the adjacent tissues avoiding deleterious effects. Various types of radionuclides can be applied to ocular brachytherapy. Those radionuclides shall be encapsulated and placed juxtaposed to the sclera, back to the tumor. Herein, a new device was developed to encapsulate the radioactive material. It can easily place back of the eyeball. A computational model of the ocular area was developed in order to simulate the spatial dose distribution promoted by the holmium-166 nuclide distributed inside the irradiator device. The simulations addressed a device placed on the surface of the sclera, rotated 90 deg taken at the normal axis forward to the lens. The simulation was carried on the code Monte Carlo MCNP5. The computational simulation generates the spatial dose distribution in the treated volume. All continuous beta and the discrete gamma and X-ray spectra emitted by the holmium-166 were incorporated on simulations. The results allow comparing the space dose distribution to other types of sources used for the same end. The sclera absorbed dose, the maximum apical tumor dose, as well as on the tumor base were investigated. Indeed, the tumor thickness defines the conditions of irradiation. The holmium-166 dose distribution provides a tool to propose a better and optimized protocol for ocular brachytherapy. (author)

  19. Study of two different radioactive sources for prostate brachytherapy treatment

    International Nuclear Information System (INIS)

    Pereira Neves, Lucio; Perini, Ana Paula; Souza Santos, William de; Caldas, Linda V.E.; Belinato, Walmir

    2015-01-01

    In this study we evaluated two radioactive sources for brachytherapy treatments. Our main goal was to quantify the absorbed doses on organs and tissues of an adult male patient, submitted to a brachytherapy treatment with two radioactive sources. We evaluated a 192 Ir and a 125 I radioactive sources. The 192 Ir radioactive source is a cylinder with 0.09 cm in diameter and 0.415 cm long. The 125 I radioactive source is also a cylinder, with 0.08 cm in diameter and 0.45 cm long. To evaluate the absorbed dose distribution on the prostate, and other organs and tissues of an adult man, a male virtual anthropomorphic phantom MASH, coupled in the radiation transport code MCNPX 2.7.0, was employed.We simulated 75, 90 and 102 radioactive sources of 125 I and one of 192 Ir, inside the prostate, as normally used in these treatments, and each treatment was simulated separately. As this phantom was developed in a supine position, the displacement of the internal organs of the chest, compression of the lungs and reduction of the sagittal diameter were all taken into account. For the 192 Ir, the higher doses values were obtained for the prostate and surrounding organs, as the colon, gonads and bladder. Considering the 125 I sources, with photons with lower energies, the doses to organs that are far from the prostate were lower. All values for the dose rates are in agreement with those recommended for brachytherapy treatments. Besides that, the new seeds evaluated in this work present usefulness as a new tool in prostate brachytherapy treatments, and the methodology employed in this work may be applied for other radiation sources, or treatments. (authors)

  20. Study of two different radioactive sources for prostate brachytherapy treatment

    Energy Technology Data Exchange (ETDEWEB)

    Pereira Neves, Lucio; Perini, Ana Paula [Instituto de Fisica, Universidade Federal de Uberlandia, Caixa Postal 593, 38400-902, Uberlandia, MG (Brazil); Souza Santos, William de; Caldas, Linda V.E. [Instituto de Pesquisas Energeticas e Nucleares, Comissao Nacional de Energia Nuclear, IPENCNEN/SP, Av. Prof. Lineu Prestes, 2242, Cidade Universitaria, 05508-000 Sao Paulo, SP (Brazil); Belinato, Walmir [Departamento de Ensino, Instituto Federal de Educacao, Ciencia e Tecnologia da Bahia, Campus Vitoria da Conquista, Zabele, Av. Amazonas 3150, 45030-220 Vitoria da Conquista, BA (Brazil)

    2015-07-01

    In this study we evaluated two radioactive sources for brachytherapy treatments. Our main goal was to quantify the absorbed doses on organs and tissues of an adult male patient, submitted to a brachytherapy treatment with two radioactive sources. We evaluated a {sup 192}Ir and a {sup 125}I radioactive sources. The {sup 192}Ir radioactive source is a cylinder with 0.09 cm in diameter and 0.415 cm long. The {sup 125}I radioactive source is also a cylinder, with 0.08 cm in diameter and 0.45 cm long. To evaluate the absorbed dose distribution on the prostate, and other organs and tissues of an adult man, a male virtual anthropomorphic phantom MASH, coupled in the radiation transport code MCNPX 2.7.0, was employed.We simulated 75, 90 and 102 radioactive sources of {sup 125}I and one of {sup 192}Ir, inside the prostate, as normally used in these treatments, and each treatment was simulated separately. As this phantom was developed in a supine position, the displacement of the internal organs of the chest, compression of the lungs and reduction of the sagittal diameter were all taken into account. For the {sup 192}Ir, the higher doses values were obtained for the prostate and surrounding organs, as the colon, gonads and bladder. Considering the {sup 125}I sources, with photons with lower energies, the doses to organs that are far from the prostate were lower. All values for the dose rates are in agreement with those recommended for brachytherapy treatments. Besides that, the new seeds evaluated in this work present usefulness as a new tool in prostate brachytherapy treatments, and the methodology employed in this work may be applied for other radiation sources, or treatments. (authors)

  1. Serum Testosterone Kinetics After Brachytherapy for Clinically Localized Prostate Cancer

    International Nuclear Information System (INIS)

    Taira, Al V.; Merrick, Gregory S.; Galbreath, Robert W.; Butler, Wayne M.; Lief, Jonathan H.; Allen, Zachariah A.; Wallner, Kent E.

    2012-01-01

    Purpose: To evaluate temporal changes in testosterone after prostate brachytherapy and investigate the potential impact of these changes on response to treatment. Methods and Materials: Between January 2008 and March 2009, 221 consecutive patients underwent Pd-103 brachytherapy without androgen deprivation for clinically localized prostate cancer. Prebrachytherapy prostate-specific antigen (PSA) and serum testosterone were obtained for each patient. Repeat levels were obtained 3 months after brachytherapy and at least every 6 months thereafter. Multiple clinical, treatment, and dosimetric parameters were evaluated to determine an association with temporal testosterone changes. In addition, analysis was conducted to determine if there was an association between testosterone changes and treatment outcomes or the occurrence of a PSA spike. Results: There was no significant difference in serum testosterone over time after implant (p = 0.57). 29% of men experienced an increase ≥25%, 23% of men experienced a decrease ≥25%, and the remaining 48% of men had no notable change in testosterone over time. There was no difference in testosterone trends between men who received external beam radiotherapy and those who did not (p = 0.12). On multivariate analysis, preimplant testosterone was the only variable that consistently predicted for changes in testosterone over time. Men with higher than average testosterone tended to experience drop in testosterone (p < 0.001), whereas men with average or below average baseline testosterone had no significant change. There was no association between men who experienced PSA spike and testosterone temporal trends (p = 0.50) nor between initial PSA response and testosterone trends (p = 0.21). Conclusion: Prostate brachytherapy does not appear to impact serum testosterone over time. Changes in serum testosterone do not appear to be associated with PSA spike phenomena nor with initial PSA response to treatment; therefore, PSA response

  2. Fully automated MRI-guided robotics for prostate brachytherapy

    International Nuclear Information System (INIS)

    Stoianovici, D.; Vigaru, B.; Petrisor, D.; Muntener, M.; Patriciu, A.; Song, D.

    2008-01-01

    The uncertainties encountered in the deployment of brachytherapy seeds are related to the commonly used ultrasound imager and the basic instrumentation used for the implant. An alternative solution is under development in which a fully automated robot is used to place the seeds according to the dosimetry plan under direct MRI-guidance. Incorporation of MRI-guidance creates potential for physiological and molecular image-guided therapies. Moreover, MRI-guided brachytherapy is also enabling for re-estimating dosimetry during the procedure, because with the MRI the seeds already implanted can be localised. An MRI compatible robot (MrBot) was developed. The robot is designed for transperineal percutaneous prostate interventions, and customised for fully automated MRI-guided brachytherapy. With different end-effectors, the robot applies to other image-guided interventions of the prostate. The robot is constructed of non-magnetic and dielectric materials and is electricity free using pneumatic actuation and optic sensing. A new motor (PneuStep) was purposely developed to set this robot in motion. The robot fits alongside the patient in closed-bore MRI scanners. It is able to stay fully operational during MR imaging without deteriorating the quality of the scan. In vitro, cadaver, and animal tests showed millimetre needle targeting accuracy, and very precise seed placement. The robot tested without any interference up to 7T. The robot is the first fully automated robot to function in MRI scanners. Its first application is MRI-guided seed brachytherapy. It is capable of automated, highly accurate needle placement. Extensive testing is in progress prior to clinical trials. Preliminary results show that the robot may become a useful image-guided intervention instrument. (author)

  3. Serum Testosterone Kinetics After Brachytherapy for Clinically Localized Prostate Cancer

    Energy Technology Data Exchange (ETDEWEB)

    Taira, Al V. [Western Radiation Oncology, Mountain View, CA (United States); Merrick, Gregory S., E-mail: gmerrick@urologicresearchinstitute.org [Schiffler Cancer Center, Wheeling Jesuit University, Wheeling, WV (United States); Galbreath, Robert W.; Butler, Wayne M.; Lief, Jonathan H.; Allen, Zachariah A. [Schiffler Cancer Center, Wheeling Jesuit University, Wheeling, WV (United States); Wallner, Kent E. [Puget Sound Healthcare Corporation Group Health Cooperative, University of Washington, Seattle, WA (United States)

    2012-01-01

    Purpose: To evaluate temporal changes in testosterone after prostate brachytherapy and investigate the potential impact of these changes on response to treatment. Methods and Materials: Between January 2008 and March 2009, 221 consecutive patients underwent Pd-103 brachytherapy without androgen deprivation for clinically localized prostate cancer. Prebrachytherapy prostate-specific antigen (PSA) and serum testosterone were obtained for each patient. Repeat levels were obtained 3 months after brachytherapy and at least every 6 months thereafter. Multiple clinical, treatment, and dosimetric parameters were evaluated to determine an association with temporal testosterone changes. In addition, analysis was conducted to determine if there was an association between testosterone changes and treatment outcomes or the occurrence of a PSA spike. Results: There was no significant difference in serum testosterone over time after implant (p = 0.57). 29% of men experienced an increase {>=}25%, 23% of men experienced a decrease {>=}25%, and the remaining 48% of men had no notable change in testosterone over time. There was no difference in testosterone trends between men who received external beam radiotherapy and those who did not (p = 0.12). On multivariate analysis, preimplant testosterone was the only variable that consistently predicted for changes in testosterone over time. Men with higher than average testosterone tended to experience drop in testosterone (p < 0.001), whereas men with average or below average baseline testosterone had no significant change. There was no association between men who experienced PSA spike and testosterone temporal trends (p = 0.50) nor between initial PSA response and testosterone trends (p = 0.21). Conclusion: Prostate brachytherapy does not appear to impact serum testosterone over time. Changes in serum testosterone do not appear to be associated with PSA spike phenomena nor with initial PSA response to treatment; therefore, PSA response

  4. Manual on brachytherapy. Incorporating: Applications guide, procedures guide, basics guide

    International Nuclear Information System (INIS)

    1996-01-01

    This publication is part of practical radiation safety manual series for different fields of application aimed primarily at persons handling radiation sources on a daily routine basis, which could at same time be used by the competent authorities, supporting their efforts in the radiation protection training of workers or medical assistance personnel or helping on-site management to set up local radiation protection rules. It is dedicated to brachytherapy: its application and procedures guides

  5. HDR brachytherapy for superficial non-melanoma skin cancers

    International Nuclear Information System (INIS)

    Gauden, Ruth; Pracy, Martin; Avery, Anne-Marie; Hodgetts, Ian; Gauden, Stan

    2013-01-01

    Our initial experience using recommended high dose per fraction skin brachytherapy (BT) treatment schedules, resulted in poor cosmesis. This study aimed to assess in a prospective group of patients the use of Leipzig surface applicators for High Dose Rate (HDR) brachytherapy, for the treatment of small non-melanoma skin cancers (NMSC) using a protracted treatment schedule. Treatment was delivered by HDR brachytherapy with Leipzig applicators. 36Gy, prescribed to between 3 to 4mm, was given in daily 3Gy fractions. Acute skin toxicity was evaluated weekly during irradiation using the Radiation Therapy Oncology Group criteria. Local response, late skin effects and cosmetic results were monitored at periodic intervals after treatment completion. From March 2002, 200 patients with 236 lesions were treated. Median follow-up was 66 months (range 25–121 months). A total of 162 lesions were macroscopic, while in 74 cases, BT was given after resection because of positive microscopic margins. There were 121 lesions that were basal cell carcinomas, and 115 were squamous cell carcinomas. Lesions were located on the head and neck (198), the extremities (26) and trunk (12). Local control was 232/236 (98%). Four patients required further surgery to treat recurrence. Grade 1 acute skin toxicity was detected in 168 treated lesions (71%) and grade 2 in 81 (34%). Cosmesis was good or excellent in 208 cases (88%). Late skin hypopigmentation changes were observed in 13 cases (5.5%). Delivering 36Gy over 2 weeks to superficial NMSC using HDR brachytherapy is well tolerated and provides a high local control rate without significant toxicity.

  6. Primary calibration of coiled 103Pd brachytherapy sources

    International Nuclear Information System (INIS)

    Paxton, Adam B.; Culberson, Wesley S.; DeWerd, Larry A.; Micka, John A.

    2008-01-01

    Coiled 103 Pd brachytherapy sources have been developed by RadioMed Corporation for use as low-dose-rate (LDR) interstitial implants. The coiled sources are provided in integer lengths from 1 to 6 cm and address many common issues seen with traditional LDR brachytherapy sources. The current standard for determining the air-kerma strength (S K ) of low-energy LDR brachytherapy sources is the National Institute of Standards and Technology's Wide-Angle Free-Air Chamber (NIST WAFAC). Due to geometric limitations, however, the NIST WAFAC is unable to determine the S K of sources longer than 1 cm. This project utilized the University of Wisconsin's Variable-Aperture Free-Air Chamber (UW VAFAC) to determine the S K of the longer coiled sources. The UW VAFAC has shown agreement in S K values of 1 cm length coils to within 1% of those determined with the NIST WAFAC, but the UW VAFAC does not share the same geometric limitations as the NIST WAFAC. A new source holder was constructed to hold the coiled sources in place during measurements with the UW VAFAC. Correction factors for the increased length of the sources have been determined and applied to the measurements. Using the new source holder and corrections, the S K of 3 and 6 cm coiled sources has been determined. Corrected UW VAFAC data and ionization current measurements from well chambers have been used to determine calibration coefficients for use in the measurement of 3 and 6 cm coiled sources in well chambers. Thus, the UW VAFAC has provided the first transferable, primary measurement of low-energy LDR brachytherapy sources with lengths greater than 1 cm

  7. Ocular brachytherapy with a holmium-166 irradiator device

    International Nuclear Information System (INIS)

    Mourao, Arnaldo P.; Campos, Tarcisio P.R.

    2009-01-01

    The ocular brachytherapy is a method that allows controlling ocular tumors. However, the irradiation of the ocular area in high doses can bring damages mainly to the surrounding healthy tissue, such as lens, retina and bone tissue of the orbital area in growth phase. Brachytherapy in comparison to teletherapy allows a large reduction of the absorbed doses in the adjacent tissues avoiding deleterious effects. Various types of radionuclides can be applied to ocular brachytherapy. Those radionuclides shall be encapsulated and placed juxtaposed to the sclera, back to the tumor. Herein, a new device was developed to encapsulate the radioactive material. It can easily place back of the eyeball. A computational model of the ocular area was developed in order to simulate the spatial dose distribution promoted by the holmium-166 nuclide distributed inside the irradiator device. The simulations addressed a device placed on the surface of the sclera, rotated 90 deg taken at the normal axis forward to the lens. The simulation was carried on the code Monte Carlo MCNP5. The computational simulation generates the spatial dose distribution in the treated volume. All continuous beta and the discrete gamma and X-ray spectra emitted by the holmium-166 were incorporated on simulations. The results allow comparing the space dose distribution to other types of sources used for the same end. The sclera absorbed dose, the maximum apical tumor dose, as well as on the tumor base were investigated. Indeed, the tumor thickness defines the conditions of irradiation. The holmium-166 dose distribution provides a tool to propose a better and optimized protocol for ocular brachytherapy. (author)

  8. Proposals for common definitions of reference points in gynecological brachytherapy

    International Nuclear Information System (INIS)

    Chassagne, D.; Horiot, J.C.

    1977-01-01

    In May 1975 the report of European Curietherapy Group recommended in gynecological Dosimetry by computer. Use of reference points = lymphatic trapezoid figure with 6 points, Pelvic wall, all points are refering to bony structures. Use of critical organ reference points = maximum rectum dose, bladder dose mean rectal dose. Use of 6,000 rads reference isodose described by height, width, and thickness dimensions. These proposals are the basis of a common language in gynecological brachytherapy [fr

  9. Ajuste teórico de las curvas PTCR de BaTiO3 dopado con niobio

    Directory of Open Access Journals (Sweden)

    Castro, M. S.

    2002-02-01

    Full Text Available In this work, a theoretical fitting to the experimental PTCR effect in slightly Nb-doped BaTiO3 from the Heywang-Jonker model is simulated. Besides, a qualitative approach was used to evaluate the GBBL characteristics of strongly Nb - doped BaTiO3. In both cases, a link between the electrical properties and the defect profile developed in these based - BaTiO3 ceramics was established. From the results, good agreement between experimental and calculated results was obtained for the PTCR ceramics. Asmall increment in Nb2O5 concentration leads to an increasing in the concentration of occupied acceptor states, the energy of the surface state and also the barrier height. In these cases, microstructural observations shown an important grain growth with average grain size between 10 and 100μm. EPR results clearly indicate low concentration of cationic vacancies for these materials. This phenomenon is associated to a charge-compensation mechanism in slightly-doped BaTiO3, that result in a semiconducting behaviour. On the other hand, the electrical behaviour of strongly–doped BaTiO3 moves away from the PTCR effect, and the material becomes insulating with noticeable GBBL characteristics. In this case, microstructural observations along defect structure analysis encourage the hypothesis in which barium vacancies act as acceptor at grain boundaries and play and important role in restricting grain growth of Nb2O5-BaTiO3 ceramics.En este trabajo se determinó la influencia de la concentración de Nb2O5 sobre el comportamiento PTCR de cerámicos basados en BaTiO3. Por otra parte, se estudió el impacto de una gran concentración del dopante sobre el comportamiento GBBL del BaTiO3. En ambos casos, se estableció una relación entre las propiedades eléctricas observadas y la estructura de defectos iónicos desarrollada. La aplicación del modelo de Heywang-Jonker permite el ajuste teórico de las curvas de resistividad – temperatura de los cerámicos PTCR

  10. El bienestar subjetivo en la adolescencia: estudio comparativo de dos Comunidades Autónomas en España

    Directory of Open Access Journals (Sweden)

    Ferran Casas

    2013-01-01

    Full Text Available Se analiza la comparabilidad interlingüística e intercultural del bienestar subjetivo durante la adolescencia, a partir de dos muestras de Asturias y de Cataluña de entre 15 y 18 años. Se utilizan como indicadores psicosociales de bienestar tres escalas: La SWLS de Diener, Emmons, Larsen y Smith (1985, escala libre de contexto (context free, el PWI de Cummins, Eckersley, van Pallant, Vugt y Misajon (2003, que evalúa el bienestar personal por ámbitos, y una escala de ítem único sobre satisfacción global con la vida (Overall Life Satisfaction = OLS. Utilizando modelos de Análisis Factorial Confirmatorio, el PWI muestra un buen ajuste para ambas muestras, avalando la comparabilidad de los resultados entre ambas poblaciones. Sus puntuaciones globales resultan más altas entre los adolescentes asturianos que entre los catalanes, igual que la OLS. La SWLS muestra un mal ajuste con los términos constantes restringidos, que añadido al hecho que el alpha de Cronbach aumentaría si el ítem 5 fuera suprimido, abunda en la idea que esta escala funciona de manera distinta en contextos socio-culturales diferentes y mantiene abiertas las dudas sobre si es apropiada su utilización como instrumento comparativo entre poblaciones de características lingüísticas y/o socioculturales distintas.

  11. Intracavitary mould brachytherapy in malignant tumors of the maxilla

    International Nuclear Information System (INIS)

    Rosenblatt, Edward; Blumenfeld, Israel; Cederbaum, Martin; Kuten, Abraham

    1996-01-01

    Purpose: To integrate brachytherapy in the combined modality management of malignant tumors of the maxilla, as a means of increasing the radiotherapy dose to the tumor bed while avoiding high doses to the orbital contents. Materials and methods: Following a partial or total maxillectomy, a duplication of the interim surgical obturator was created using a wash of vinyl polysiloxane. This mould was used as a carrier for afterloading nylon catheters through which 192-Iridium seed-ribbons were inserted. Following brachytherapy, selected patients also received external beam irradiation. Results and discussion: After a median follow-up of 36 months, 9 out of 11 patients are alive and disease-free; 1 developed a local recurrence and another relapsed at another site in the oral cavity. Transient grade 1 - 2 mucositis at the implant site was observed in all patients. The review of computer isodose distributions showed that the average dose received by the homolateral eyeball was 10% (range 9,2 - 10.0) of the prescribed surface dose to the surgical cavity. Conclusions: Brachytherapy can be integrated in the management of patients with malignant tumors of the maxilla in the form of a custom-made intracavitary mould carrying 192-Iridium sources. We found this technique particularly useful in cases with close or positive surgical margins

  12. Visual acuity after Ruthenium106 brachytherapy of choroidal melanomas

    International Nuclear Information System (INIS)

    Damato, Bertil; Patel, Imran M.; Campbell, Ian R.; Mayles, Helen M.; Errington, R. Douglas

    2005-01-01

    Purpose: To report on conservation of visual acuity after Ruthenium 106 (Ru-106) brachytherapy of choroidal melanoma. Methods and materials: This study was a noncomparative interventional case series of 458 patients with choroidal melanoma treated at a single center between January 1993 and December 2001. The intervention consisted of Ru-106 brachytherapy delivering minimum scleral and apex doses of 300 Gy and 80 Gy, respectively, using a 15-mm or 20-mm plaque. For discrete, posterior tumors, the plaque was positioned eccentrically with its posterior edge aligned with the posterior tumor margin. To ensure correct plaque positioning, any overlying extraocular muscles were dis-inserted, and the locations of both tumor and plaque edges were confirmed by transillumination and indentation. The main outcome measures were conservation of vision of 20/40 or better, 20/200 or better, and Counting Fingers or better, according to baseline variables. Results: The actuarial rate of conservation of 20/40 or better was 55% at 9 years, loss of such vision correlating with posterior tumor extension (p 106 brachytherapy of posterior choroidal melanoma achieves good conservation of vision if the tumor does not extend close to the optic nerve or fovea

  13. Invited review, recent developments in brachytherapy source dosimetry

    International Nuclear Information System (INIS)

    Meigooni, A.S.

    2004-01-01

    Application of radioactive isotopes is the treatment of choice around the globe for many cancer sites. In this technique, the accuracy of the radiation delivery is highly dependent on the accuracy of radiation dosimetry around individual brachytherapy sources. Moreover, in order to have compatible clinical results, an identical method of source dosimetry must be employed across the world. This problem has been recently addressed by task group 43 from the American Association of Medical Physics with a protocol for dosimetric characterization of brachytherapy sources. This new protocol has been further updated using published data from international sources, by a new Task Group from the American Association of Medical Physics. This has resulted in an updated protocol known as TG43U1 that has been published in March 2004 issue of Medical Physics. The goal of this presentation is to review the original Task Group 43 protocol and associated algorithms for brachytherapy source dosimetry. In addition, the shortcomings of the original protocol that has been resolved in the updated recommendation will be highlighted. I am sure that this is not the end of the line and more work is needed to complete this task. I invite the scientists to join this task and complete the project, with the hope of much better clinical results for cancer patients

  14. Radiation safety program in a high dose rate brachytherapy facility

    International Nuclear Information System (INIS)

    Rodriguez, L.V.; Hermoso, T.M.; Solis, R.C.

    2001-01-01

    The use of remote afterloading equipment has been developed to improve radiation safety in the delivery of treatment in brachytherapy. Several accidents, however, have been reported involving high dose-rate brachytherapy system. These events, together with the desire to address the concerns of radiation workers, and the anticipated adoption of the International Basic Safety Standards for Protection Against Ionizing Radiation (IAEA, 1996), led to the development of the radiation safety program at the Department of Radiotherapy, Jose R. Reyes Memorial Medical Center and at the Division of Radiation Oncology, St. Luke's Medical Center. The radiation safety program covers five major aspects: quality control/quality assurance, radiation monitoring, preventive maintenance, administrative measures and quality audit. Measures for evaluation of effectiveness of the program include decreased unnecessary exposures of patients and staff, improved accuracy in treatment delivery and increased department efficiency due to the development of staff vigilance and decreased anxiety. The success in the implementation required the participation and cooperation of all the personnel involved in the procedures and strong management support. This paper will discuss the radiation safety program for a high dose rate brachytherapy facility developed at these two institutes which may serve as a guideline for other hospitals intending to install a similar facility. (author)

  15. Survey of brachytherapy practice in France in 1995. Definitive results

    International Nuclear Information System (INIS)

    Peiffert, D.; Simon, J.M.; Baillet, F.

    1998-01-01

    A survey questionnaire was sent to the 189 French departments of radiation Oncology and 166 responded (88%). Ninety-nine departments declared treating patients by brachytherapy and 358 shielded rooms were available. In Low Dose Rate (LDR) 81 departments used Cesium sources (159 after-loaders, 1,060 sources); Iridium wires were used by 84 departments (673 meters used). Only six departments used other elements. Twenty-six departments were equipped with high dose rate after loaders (HDR) all of them also using LDR techniques for most of the patients. A total of 9,160 patients were treated: 7,868 with LDR and 1,292 with HDR. The common sites treated by LDR were utero-vagina (4,300), breast (1,415), head and neck (1,409), skin (610), anorectal (220) and urologic (70). HDR was used for vaginal cuff (628), bronchi (371), oesophagus (232). PDR just started (33 patients) for a feasibility trial. The rate of patients treated by brachytherapy is around 6-8% of the irradiated patients, but the indications vary is each department. The diffusion of the techniques, and new indications should increase the number of patients being treated by brachytherapy. (authors)

  16. Radiobiological considerations in gynaecological HDR and LDR brachytherapy

    International Nuclear Information System (INIS)

    Bauer, M.; Schulz-Wendtland, R.

    1989-01-01

    In brachytherapy the advantages of high dose rate over low dose rate afterloading therapy were obvious. Out-patient treatment becomes possible, the position of the sources is reproducible and can be observed during the treatment and the patients have to be immobilised for only a short time, giving less psychological stress and a decreased risk of thrombosis and embolism. When changing from LDR to HDR afterloading therapy we are not yet able to evaluate its biological impact. Radiobiological considerations and our experimental data, however, give us the following clinical consequences by using HDR brachytherapy: There is a need for about 15 fractions or more and each increase in dose rate requires higher fractioning. Due to the steep dose rate decline and the inhomogeneous dose distribution, multiple equivalence factors are necessary when fractioning is not sufficiently high. Correction factors to reduce the dose close to the source are low, with increasing distance from the source they increase. If HDR radiation therapy is used, the percutaneous dose in the pelvic wall region should be reduced. The reduction of the dose in HDR brachytherapy is a compromise to limit the side effects caused by the radiation. The drawback is a small therapeutic range and reduced therapeutic effectivity at the tumour. (orig.) [de

  17. Brachytherapy for treatment of cervix cancer in Madagascar

    International Nuclear Information System (INIS)

    Pignon, T.; Ratovonarivo, H.; Rafaramino, F.; Ruggieri, S.

    1993-01-01

    From March 1986 to June 1988, 60 patients with carcinoma of the uterine cervix were treated by radiotherapy alone or combined radiotherapy and surgery at the only radiotherapy-oncology department of Madagascar in Antananarivo. There were 20 stage IB, 28 stage II, 5 stage III and 7 cases where initial stage before surgery was unknown. After a limited pre-therapeutic investigation, treatment for stage IB consisted of utero-vaginal brachytherapy followed by a colpo-hysterectomy and external iliac lymphadenectomy. Others received combined external radiotherapy and brachytherapy according to the Fletcher guidelines, although 30 patients also received surgery. An obsolete and inefficient cobalt unit with lack of computerized dosimetry made the management of therapeutic schemas difficult. Nineteen patients (31.6%) were not available for follow-up immediately after the end of the treatment and one patient died from intestinal occlusion during brachytherapy. The overall rate of severe complications was 4.8%. There were 12 recurrences which occurred in stage II or in patients with unknown initial staging. At the time of analysis, 25 patients were alive: 15 stage I and 10 stage II. In this country, cervical carcinomas are the most frequent tumors: only the rehabilitation of radiotherapy facilities will allow results to be improved

  18. Patterns of care for brachytherapy in Europe: Updated results

    International Nuclear Information System (INIS)

    Guedea, Ferran; Venselaar, Jack; Hoskin, Peter; Hellebust, Taran Paulsen; Peiffert, Didier; Londres, Bradley; Ventura, Montse; Mazeron, Jean-Jacques; Van Limbergen, Erik; Poetter, Richard; Kovacs, Gyorgy

    2010-01-01

    Objective: This descriptive survey evaluated brachytherapy (BT) practices and resources in the European area. This was a follow-up study to the original patterns of care for brachytherapy in Europe (PCBE). Materials and methods: A total of 1121 radiotherapy (RT) centres from 41 countries were asked to complete an online questionnaire on BT practices and resources. Countries with fewer than 50% of centres responding were excluded. Participating countries were divided into three groups based on gross domestic product (GDP); group I contained the countries with the highest GDP. Results: The response rate was 56% (633/1121 centres) with 30/41 countries (73%) meeting the inclusion criteria. Sixty percent of reporting centres provided brachytherapy. Responding centres treated an average of 138 (±10, 1 SD) patients with BT; in group I, the mean was 110/centre, an increase of 18% from 2002. CT-dosimetry increased to 61% of centres vs. 33% in 2002. HDR (high-dose rate) BT was the most commonly reported technique (65% of centres). Most BT interventions were for gynaecological tumors (59% of all cases), followed by prostate (17%), breast (9%), lung/bronchus (3%), and esophagus tumors(2%). Conclusion: Gynaecological BT remains the most common application, although both prostate and breast BT have increased. CT-based dosimetry has become increasingly common since 2002. The use of HDR and PDR (pulsed-dose rate) techniques has increased markedly, while both LDR and MDR (medium-dose rate) have declined.

  19. Implication for QOL after I-125 brachytherapy for prostate cancer

    International Nuclear Information System (INIS)

    Teishima, Jun; Yasumoto, Hiroaki; Inoue, Syogo; Masumoto, Hiroshi; Hasegawa, Yasuhisa; Matsubara, Akio

    2009-01-01

    The aim of this study is to evaluate the quality of life (QOL) of patients following prostate brachytherapy. Between July 2004 and May 2008, 139 patients underwent I-125 permanent brachytherapy. Among those patients, 69 who were followed up for more than one year using the Expanded Prostate Index Composite (EPIC), Japanese version v1 TM , were enrolled in this study. Urinary summary scores became worse temporarily at 1 month after the end of treatment, but then recovered gradually to the level before treatment. Sexual summary scores before treatment were 42.2±16.3. They became worse temporarily at 1 month after treatment but then recovered gradually in patients whose sexual summary scores were more than 40. Urinary morbidity scores after prostate brachytherapy were not so severe and recovered within a short period. Further long-term observation is thought to be required in the future. Sexual function scores of patients before treatment in the present study were lower compared with those recorded in previous studies. (author)

  20. Audits in high dose rate brachytherapy in Brazil

    International Nuclear Information System (INIS)

    Marechal, M.H.; Rosa, L.A.; Velasco, A.; Paiva, E. de; Goncalves, M.; Castelo, L.C.

    2002-01-01

    The lack of well established dosimetry protocols for HDR sources is a point of great concern regarding the uniformity of procedures within a particular country. The main objective of this paper is to report the results of an implementation of the audit program in dosimetry of high dose rate brachytherapy sources used by the radiation therapy centers in Brazil. In Brazil, among 169 radiotherapy centers, 35 have HDR brachytherapy systems. This program started in August 2001 and until now eight radiotherapy services were audited. The audit program consists of the visit in loco to each center and the evaluation of the intensity of the source with a well type chamber specially design for HDR 192 Ir sources. The measurements was carried out with a HDR1000PLUS Brachytherapy Well Type Chamber and a MAX 4000 Electrometer, both manufactured by Standard Imaging Inc. The chamber was calibrated in air kerma strength by the Accredited Dosimetry Calibration Laboratory, Department of Medical Physics, University of Wisconsin in the USA. The same chamber was calibrated in Brazil using a 192 lr high dose rate source whose intensity was determined by 60 Co gamma rays and 250 kV x rays interpolation methodology. The Nk of 60 Co and 250 kV x rays were provided by the Brazilian National Standard Laboratory for Ionizing Radiation (LMNRI)

  1. Does immediate postoperative brachytherapy allow to broaden the indications of conservative treatment in breast cancer?

    International Nuclear Information System (INIS)

    Floiras, J.L.

    1998-01-01

    A 1997 study of long-term outcomes in 109 patients with unilateral stage I or II breast cancer treated by brachytherapy between 1983 and 1985 found significantly lower recurrence rates than in a conservatively-treated group of patients managed at the same institution. The benefits of brachytherapy, of a booster dose after after surgery, and of adjuvant medical therapy are emphasized. (author)

  2. A compilation of current regulations, standards and guidelines in remote afterloading brachytherapy

    Energy Technology Data Exchange (ETDEWEB)

    Tortorelli, J.P.; Simion, G.P.; Kozlowski, S.D. [Idaho National Engineering Lab., Idaho Falls, ID (United States)

    1994-10-01

    Over a dozen government and professional organizations in the United States and Europe have issued regulations and guidance concerning quality management in the practice of remote afterloading brachytherapy. Information from the publications of these organizations was collected and collated for this report. This report provides the brachytherapy licensee access to a broad field of quality management information in a single, topically organized document.

  3. A compilation of current regulations, standards and guidelines in remote afterloading brachytherapy

    International Nuclear Information System (INIS)

    Tortorelli, J.P.; Simion, G.P.; Kozlowski, S.D.

    1994-10-01

    Over a dozen government and professional organizations in the United States and Europe have issued regulations and guidance concerning quality management in the practice of remote afterloading brachytherapy. Information from the publications of these organizations was collected and collated for this report. This report provides the brachytherapy licensee access to a broad field of quality management information in a single, topically organized document

  4. American Brachytherapy Society Task Group Report: Combination of brachytherapy and external beam radiation for high-risk prostate cancer.

    Science.gov (United States)

    Spratt, Daniel E; Soni, Payal D; McLaughlin, Patrick W; Merrick, Gregory S; Stock, Richard G; Blasko, John C; Zelefsky, Michael J

    To review outcomes for high-risk prostate cancer treated with combined modality radiation therapy (CMRT) utilizing external beam radiation therapy (EBRT) with a brachytherapy boost. The available literature for high-risk prostate cancer treated with combined modality radiation therapy was reviewed and summarized. At this time, the literature suggests that the majority of high-risk cancers are curable with multimodal treatment. Several large retrospective studies and three prospective randomized trials comparing CMRT to dose-escalated EBRT have demonstrated superior biochemical control with CMRT. Longer followup of the randomized trials will be required to determine if this will translate to a benefit in metastasis-free survival, disease-specific survival, and overall survival. Although greater toxicity has been associated with CMRT compared to EBRT, recent studies suggest that technological advances that allow better definition and sparing of critical adjacent structures as well as increasing experience with brachytherapy have improved implant quality and the toxicity profile of brachytherapy. The role of androgen deprivation therapy is well established in the external beam literature for high-risk disease, but there is controversy regarding the applicability of these data in the setting of dose escalation. At this time, there is not sufficient evidence for the omission of androgen deprivation therapy with dose escalation in this population. Comparisons with surgery remain limited by differences in patient selection, but the evidence would suggest better disease control with CMRT compared to surgery alone. Due to a series of technological advances, modern combination series have demonstrated unparalleled rates of disease control in the high-risk population. Given the evidence from recent randomized trials, combination therapy may become the standard of care for high-risk cancers. Copyright © 2016 American Brachytherapy Society. Published by Elsevier Inc. All

  5. Contemporary Toxicity Profile of Breast Brachytherapy Versus External Beam Radiation After Lumpectomy for Breast Cancer

    International Nuclear Information System (INIS)

    Huo, Jinhai; Giordano, Sharon H.; Smith, Benjamin D.; Shaitelman, Simona F.; Smith, Grace L.

    2016-01-01

    Purpose: We compared toxicities after brachytherapy versus external beam radiation therapy (EBRT) in contemporary breast cancer patients. Methods and Materials: Using MarketScan healthcare claims, we identified 64,112 women treated from 2003 to 2012 with lumpectomy followed by radiation (brachytherapy vs EBRT). Brachytherapy was further classified by multichannel versus single-channel applicator approach. We identified the risks and predictors of 1-year infectious and noninfectious postoperative adverse events using logistic regression and temporal trends using Cochran-Armitage tests. We estimated the 5-year Kaplan-Meier cumulative incidence of radiation-associated adverse events. Results: A total of 4522 (7.1%) patients received brachytherapy (50.2% multichannel vs 48.7% single-channel applicator). The overall risk of infectious adverse events was higher after brachytherapy than after EBRT (odds ratio [OR] = 1.21; 95% confidence interval [CI] 1.09-1.34, P<.001). However, over time, the frequency of infectious adverse events after brachytherapy decreased, from 17.3% in 2003 to 11.6% in 2012, and was stable after EBRT at 9.7%. Beyond 2007, there were no longer excess infections with brachytherapy (P=.97). The overall risk of noninfectious adverse events was higher after brachytherapy than after EBRT (OR=2.27; 95% CI 2.09-2.47, P<.0001). Over time, the frequency of noninfectious adverse events detected increased: after multichannel brachytherapy, from 9.1% in 2004 to 18.9% in 2012 (Ptrend = .64); single-channel brachytherapy, from 12.8% to 29.8% (Ptrend<.001); and EBRT, from 6.1% to 10.3% (Ptrend<.0001). The risk was significantly higher with single-channel than with multichannel brachytherapy (hazard ratio = 1.32; 95% CI 1.03-1.69, P=.03). Of noninfectious adverse events, 70.9% were seroma. Seroma significantly increased breast pain risk (P<.0001). Patients with underlying diabetes, cardiovascular disease, and treatment with chemotherapy had increased

  6. Contemporary Toxicity Profile of Breast Brachytherapy Versus External Beam Radiation After Lumpectomy for Breast Cancer

    Energy Technology Data Exchange (ETDEWEB)

    Huo, Jinhai [Department of Health Services Research, The University of Texas MD Anderson Cancer Center, Houston, Texas (United States); Giordano, Sharon H. [Department of Health Services Research, The University of Texas MD Anderson Cancer Center, Houston, Texas (United States); Department of Breast Medical Oncology, The University of Texas MD Anderson Cancer Center, Houston, Texas (United States); Smith, Benjamin D. [Department of Health Services Research, The University of Texas MD Anderson Cancer Center, Houston, Texas (United States); Department of Radiation Oncology, The University of Texas MD Anderson Cancer Center, Houston, Texas (United States); Shaitelman, Simona F. [Department of Radiation Oncology, The University of Texas MD Anderson Cancer Center, Houston, Texas (United States); Smith, Grace L., E-mail: glsmith@mdanderson.org [Department of Health Services Research, The University of Texas MD Anderson Cancer Center, Houston, Texas (United States); Department of Radiation Oncology, The University of Texas MD Anderson Cancer Center, Houston, Texas (United States)

    2016-03-15

    Purpose: We compared toxicities after brachytherapy versus external beam radiation therapy (EBRT) in contemporary breast cancer patients. Methods and Materials: Using MarketScan healthcare claims, we identified 64,112 women treated from 2003 to 2012 with lumpectomy followed by radiation (brachytherapy vs EBRT). Brachytherapy was further classified by multichannel versus single-channel applicator approach. We identified the risks and predictors of 1-year infectious and noninfectious postoperative adverse events using logistic regression and temporal trends using Cochran-Armitage tests. We estimated the 5-year Kaplan-Meier cumulative incidence of radiation-associated adverse events. Results: A total of 4522 (7.1%) patients received brachytherapy (50.2% multichannel vs 48.7% single-channel applicator). The overall risk of infectious adverse events was higher after brachytherapy than after EBRT (odds ratio [OR] = 1.21; 95% confidence interval [CI] 1.09-1.34, P<.001). However, over time, the frequency of infectious adverse events after brachytherapy decreased, from 17.3% in 2003 to 11.6% in 2012, and was stable after EBRT at 9.7%. Beyond 2007, there were no longer excess infections with brachytherapy (P=.97). The overall risk of noninfectious adverse events was higher after brachytherapy than after EBRT (OR=2.27; 95% CI 2.09-2.47, P<.0001). Over time, the frequency of noninfectious adverse events detected increased: after multichannel brachytherapy, from 9.1% in 2004 to 18.9% in 2012 (Ptrend = .64); single-channel brachytherapy, from 12.8% to 29.8% (Ptrend<.001); and EBRT, from 6.1% to 10.3% (Ptrend<.0001). The risk was significantly higher with single-channel than with multichannel brachytherapy (hazard ratio = 1.32; 95% CI 1.03-1.69, P=.03). Of noninfectious adverse events, 70.9% were seroma. Seroma significantly increased breast pain risk (P<.0001). Patients with underlying diabetes, cardiovascular disease, and treatment with chemotherapy had increased

  7. ALGEBRA: ALgorithm for the heterogeneous dosimetry based on GEANT4 for BRAchytherapy.

    Science.gov (United States)

    Afsharpour, H; Landry, G; D'Amours, M; Enger, S; Reniers, B; Poon, E; Carrier, J-F; Verhaegen, F; Beaulieu, L

    2012-06-07

    Task group 43 (TG43)-based dosimetry algorithms are efficient for brachytherapy dose calculation in water. However, human tissues have chemical compositions and densities different than water. Moreover, the mutual shielding effect of seeds on each other (interseed attenuation) is neglected in the TG43-based dosimetry platforms. The scientific community has expressed the need for an accurate dosimetry platform in brachytherapy. The purpose of this paper is to present ALGEBRA, a Monte Carlo platform for dosimetry in brachytherapy which is sufficiently fast and accurate for clinical and research purposes. ALGEBRA is based on the GEANT4 Monte Carlo code and is capable of handling the DICOM RT standard to recreate a virtual model of the treated site. Here, the performance of ALGEBRA is presented for the special case of LDR brachytherapy in permanent prostate and breast seed implants. However, the algorithm is also capable of handling other treatments such as HDR brachytherapy.

  8. Dosimetry Modeling for Focal Low-Dose-Rate Prostate Brachytherapy

    Energy Technology Data Exchange (ETDEWEB)

    Al-Qaisieh, Bashar [Leeds Cancer Centre, Leeds Teaching Hospitals NHS Trust, Leeds (United Kingdom); Mason, Josh, E-mail: joshua.mason@nhs.net [Leeds Cancer Centre, Leeds Teaching Hospitals NHS Trust, Leeds (United Kingdom); Bownes, Peter; Henry, Ann [Leeds Cancer Centre, Leeds Teaching Hospitals NHS Trust, Leeds (United Kingdom); Dickinson, Louise [Division of Surgery and Interventional Science, University College London, London (United Kingdom); Department of Radiology, Northwick Park Hospital, London North West NHS Trust, London (United Kingdom); Ahmed, Hashim U. [Division of Surgery and Interventional Science, University College London, London (United Kingdom); University College London Hospital, London (United Kingdom); Emberton, Mark [University College London Hospital, London (United Kingdom); Langley, Stephen [St Luke' s Cancer Centre, Guildford (United Kingdom)

    2015-07-15

    Purpose: Focal brachytherapy targeted to an individual lesion(s) within the prostate may reduce side effects experienced with whole-gland brachytherapy. The outcomes of a consensus meeting on focal prostate brachytherapy were used to investigate optimal dosimetry of focal low-dose-rate (LDR) prostate brachytherapy targeted using multiparametric magnetic resonance imaging (mp-MRI) and transperineal template prostate mapping (TPM) biopsy, including the effects of random and systematic seed displacements and interseed attenuation (ISA). Methods and Materials: Nine patients were selected according to clinical characteristics and concordance of TPM and mp-MRI. Retrospectively, 3 treatment plans were analyzed for each case: whole-gland (WG), hemi-gland (hemi), and ultra-focal (UF) plans, with 145-Gy prescription dose and identical dose constraints for each plan. Plan robustness to seed displacement and ISA were assessed using Monte Carlo simulations. Results: WG plans used a mean 28 needles and 81 seeds, hemi plans used 17 needles and 56 seeds, and UF plans used 12 needles and 25 seeds. Mean D90 (minimum dose received by 90% of the target) and V100 (percentage of the target that receives 100% dose) values were 181.3 Gy and 99.8% for the prostate in WG plans, 195.7 Gy and 97.8% for the hemi-prostate in hemi plans, and 218.3 Gy and 99.8% for the focal target in UF plans. Mean urethra D10 was 205.9 Gy, 191.4 Gy, and 92.4 Gy in WG, hemi, and UF plans, respectively. Mean rectum D2 cm{sup 3} was 107.5 Gy, 77.0 Gy, and 42.7 Gy in WG, hemi, and UF plans, respectively. Focal plans were more sensitive to seed displacement errors: random shifts with a standard deviation of 4 mm reduced mean target D90 by 14.0%, 20.5%, and 32.0% for WG, hemi, and UF plans, respectively. ISA has a similar impact on dose-volume histogram parameters for all plan types. Conclusions: Treatment planning for focal LDR brachytherapy is feasible. Dose constraints are easily met with a notable

  9. Relocation of a nucletron microselectron-HDR brachytherapy system

    Energy Technology Data Exchange (ETDEWEB)

    Bartrum, T; Tran, T; Freeman, N; Morales, J [St Vincents Hospital, Darlinghurst, NSW (Australia)

    2004-12-15

    Full text: For a period of four weeks, our clinical Nucletron microSelectron high dose rate (HDR) brachytherapy system was pulled out of clinical use and relocated to a new building. During this period decommission tests, de-wiring of the treatment unit and its associated safety system (such as radiation detector, emergency off circuits and door interlocks), transportation of all equipment, re-wiring of this equipment in the new location and recommission tests were carried out. The decommission and recommission test program was designed upon consultation with the manufacturer's (Nucletron) acceptance test procedures and work carried out by others. The ACPSEM tolerances for remote afterloaders was used as a guideline. In addition to mandatory dosimetry, positional, workstation database and safety tests, two Australian Standard compliance tests were carried out. The compliance tests involved one for remote afterloaders and another for treatment room design. This testing program was designed and implemented with the aim of ensuring ongoing safe delivery of brachytherapy doses to the patient. The testing program consisted of two parts. The first involved a series of decommissioning tests that consisted of dosimetry tests such as source and check cable positional accuracy and source calibration tests. In addition to these tests an inventory of standard plans, patient records and system configuration information was catalogued. The second part involved a series of recommission tests and involved carrying out dosimetry tests on the brachytherapy system (positional accuracy and calibration tests), simulating common treatment scenarios (prostate, cervical, vaginal and bile duct) and checking standard plans; patient records and system configuration had remained unchanged. During this period, other tests were carried out. These included Nucletron acceptance and preventative maintenance tests, Australian Standards compliance testing and integrity of network transfer of

  10. Relocation of a nucletron microselectron-HDR brachytherapy system

    International Nuclear Information System (INIS)

    Bartrum, T.; Tran, T.; Freeman, N.; Morales, J.

    2004-01-01

    Full text: For a period of four weeks, our clinical Nucletron microSelectron high dose rate (HDR) brachytherapy system was pulled out of clinical use and relocated to a new building. During this period decommission tests, de-wiring of the treatment unit and its associated safety system (such as radiation detector, emergency off circuits and door interlocks), transportation of all equipment, re-wiring of this equipment in the new location and recommission tests were carried out. The decommission and recommission test program was designed upon consultation with the manufacturer's (Nucletron) acceptance test procedures and work carried out by others. The ACPSEM tolerances for remote afterloaders was used as a guideline. In addition to mandatory dosimetry, positional, workstation database and safety tests, two Australian Standard compliance tests were carried out. The compliance tests involved one for remote afterloaders and another for treatment room design. This testing program was designed and implemented with the aim of ensuring ongoing safe delivery of brachytherapy doses to the patient. The testing program consisted of two parts. The first involved a series of decommissioning tests that consisted of dosimetry tests such as source and check cable positional accuracy and source calibration tests. In addition to these tests an inventory of standard plans, patient records and system configuration information was catalogued. The second part involved a series of recommission tests and involved carrying out dosimetry tests on the brachytherapy system (positional accuracy and calibration tests), simulating common treatment scenarios (prostate, cervical, vaginal and bile duct) and checking standard plans; patient records and system configuration had remained unchanged. During this period, other tests were carried out. These included Nucletron acceptance and preventative maintenance tests, Australian Standards compliance testing and integrity of network transfer of

  11. Determining profile of dose distribution for PD-103 brachytherapy source

    International Nuclear Information System (INIS)

    Berkay, Camgoz; Mehmet, N. Kumru; Gultekin, Yegin

    2006-01-01

    Full text: Brachytherapy is a particular radiotherapy for cancer treatments. By destructing cancerous cells using radiation, the treatment proceeded. When alive tissues are subject it is hazardous to study experimental. For brachytherapy sources generally are studied as theoretical using computer simulation. General concept of the treatment is to locate the radioactive source into cancerous area of related tissue. In computer studies Monte Carlo mathematical method that is in principle based on random number generations, is used. Palladium radioisotope is LDR (Low radiation Dose Rate) source. Main radioactive material was coated with titanium cylinder with 3mm length, 0.25 mm radius. There are two parts of Pd-103 in the titanium cylinder. It is impossible to investigate differential effects come from two part as experimental. Because the source dimensions are small compared with measurement distances. So there is only simulation method. In dosimetric studies it is aimed to determine absorbed dose distribution in tissue as radial and angular. In nuclear physics it is obligation to use computer based methods for researchers. Radiation studies have hazards for scientist and people interacted with radiation. When hazard exceed over recommended limits or physical conditions are not suitable (long work time, non economical experiments, inadequate sensitivity of materials etc.) it is unavoidable to simulate works and experiments before practices of scientific methods in life. In medical area, usage of radiation is required computational work for cancer treatments. Some computational studies are routine in clinics and other studies have scientific development purposes. In brachytherapy studies there are significant differences between experimental measurements and theoretical (computer based) output data. Errors of data taken from experimental studies are larger than simulation values errors. In design of a new brachytherapy source it is important to consider detailed

  12. Third-party brachytherapy source calibrations and physicist responsibilities: Report of the AAPM Low Energy Brachytherapy Source Calibration Working Group

    International Nuclear Information System (INIS)

    Butler, Wayne M.; Bice, William S. Jr.; DeWerd, Larry A.; Hevezi, James M.; Huq, M. Saiful; Ibbott, Geoffrey S.; Palta, Jatinder R.; Rivard, Mark J.; Seuntjens, Jan P.; Thomadsen, Bruce R.

    2008-01-01

    The AAPM Low Energy Brachytherapy Source Calibration Working Group was formed to investigate and recommend quality control and quality assurance procedures for brachytherapy sources prior to clinical use. Compiling and clarifying recommendations established by previous AAPM Task Groups 40, 56, and 64 were among the working group's charges, which also included the role of third-party handlers to perform loading and assay of sources. This document presents the findings of the working group on the responsibilities of the institutional medical physicist and a clarification of the existing AAPM recommendations in the assay of brachytherapy sources. Responsibility for the performance and attestation of source assays rests with the institutional medical physicist, who must use calibration equipment appropriate for each source type used at the institution. Such equipment and calibration procedures shall ensure secondary traceability to a national standard. For each multi-source implant, 10% of the sources or ten sources, whichever is greater, are to be assayed. Procedures for presterilized source packaging are outlined. The mean source strength of the assayed sources must agree with the manufacturer's stated strength to within 3%, or action must be taken to resolve the difference. Third party assays do not absolve the institutional physicist from the responsibility to perform the institutional measurement and attest to the strength of the implanted sources. The AAPM leaves it to the discretion of the institutional medical physicist whether the manufacturer's or institutional physicist's measured value should be used in performing dosimetry calculations

  13. Influencia de los cementos y de los diseños protésicos en el ajuste interno de estructuras de zirconia confeccionadas mediante tecnología Cad-Cam para prótesis fija

    OpenAIRE

    Sánchez Monescillo, Andrés

    2015-01-01

    1. INTRODUCCIÓN Y JUSTIFICACIÓN Aún quedan gran cantidad de elementos y variables que pueden influir en el ajuste interno de las restauraciones y cuyo desconocimiento obliga a seguir investigando. Este estudio permite conocer si existe una influencia real en el ajuste interno de estructuras de zirconia fabricadas mediante tecnología CAD-CAM en función del tipo de cemento utilizado y del tipo de convergencia oclusal de la preparación realizada. 2. OBJETIVOS - Evaluar la influencia de disti...

  14. WE-F-BRD-01: HDR Brachytherapy II: Integrating Imaging with HDR

    Energy Technology Data Exchange (ETDEWEB)

    Craciunescu, O [Duke University Medical Center, Durham, NC (United States); Todor, D [Virginia Commonwealth University, Richmond, VA (United States); Leeuw, A de

    2014-06-15

    In recent years, with the advent of high/pulsed dose rate afterloading technology, advanced treatment planning systems, CT/MRI compatible applicators, and advanced imaging platforms, image-guided adaptive brachytherapy treatments (IGABT) have started to play an ever increasing role in modern radiation therapy. The most accurate way to approach IGABT treatment is to provide the infrastructure that combines in a single setting an appropriate imaging device, a treatment planning system, and a treatment unit. The Brachytherapy Suite is not a new concept, yet the modern suites are incorporating state-of-the-art imaging (MRI, CBCT equipped simulators, CT, and /or US) that require correct integration with each other and with the treatment planning and delivery systems. Arguably, an MRI-equipped Brachytherapy Suite is the ideal setup for real-time adaptive brachytherapy treatments. The main impediment to MRI-IGABT adoption is access to MRI scanners. Very few radiation oncology departments currently house MRI scanners, and even fewer in a dedicated Brachytherapy Suite. CBCT equipped simulators are increasingly offered by manufacturers as part of a Brachytherapy Suite installation. If optimized, images acquired can be used for treatment planning, or can be registered with other imaging modalities. This infrastructure is relevant for all forms of brachytherapy, especially those utilizing multi-fractionated courses of treatment such as prostate and cervix. Moreover, for prostate brachytherapy, US imaging systems can be part of the suite to allow for real-time HDR/LDR treatments. Learning Objectives: Understand the adaptive workflow of MR-based IGBT for cervical cancer. Familiarize with commissioning aspects of a CBCT equipped simulator with emphasis on brachytherapy applications Learn about the current status and future developments in US-based prostate brachytherapy.

  15. WE-F-BRD-01: HDR Brachytherapy II: Integrating Imaging with HDR

    International Nuclear Information System (INIS)

    Craciunescu, O; Todor, D; Leeuw, A de

    2014-01-01

    In recent years, with the advent of high/pulsed dose rate afterloading technology, advanced treatment planning systems, CT/MRI compatible applicators, and advanced imaging platforms, image-guided adaptive brachytherapy treatments (IGABT) have started to play an ever increasing role in modern radiation therapy. The most accurate way to approach IGABT treatment is to provide the infrastructure that combines in a single setting an appropriate imaging device, a treatment planning system, and a treatment unit. The Brachytherapy Suite is not a new concept, yet the modern suites are incorporating state-of-the-art imaging (MRI, CBCT equipped simulators, CT, and /or US) that require correct integration with each other and with the treatment planning and delivery systems. Arguably, an MRI-equipped Brachytherapy Suite is the ideal setup for real-time adaptive brachytherapy treatments. The main impediment to MRI-IGABT adoption is access to MRI scanners. Very few radiation oncology departments currently house MRI scanners, and even fewer in a dedicated Brachytherapy Suite. CBCT equipped simulators are increasingly offered by manufacturers as part of a Brachytherapy Suite installation. If optimized, images acquired can be used for treatment planning, or can be registered with other imaging modalities. This infrastructure is relevant for all forms of brachytherapy, especially those utilizing multi-fractionated courses of treatment such as prostate and cervix. Moreover, for prostate brachytherapy, US imaging systems can be part of the suite to allow for real-time HDR/LDR treatments. Learning Objectives: Understand the adaptive workflow of MR-based IGBT for cervical cancer. Familiarize with commissioning aspects of a CBCT equipped simulator with emphasis on brachytherapy applications Learn about the current status and future developments in US-based prostate brachytherapy

  16. Interstitial high-dose-rate brachytherapy in the treatment of base of tongue carcinoma

    Energy Technology Data Exchange (ETDEWEB)

    Takacsi-Nagy, Z.; Polgar, C.; Somogyi, A.; Major, T.; Fodor, J.; Nemeth, G. [Dept. of Radiotherapy, National Inst. of Oncology, Budapest (Hungary); Oberna, F. [Dept. of Maxillofacial Surgery, St. Rokus Hospital, Budapest (Hungary); Remenar, E.; Kasler, M. [Dept. of Head and Neck, Maxillofacial and Reconstructive Plastic Surgery, National Inst. of Oncology, Budapest (Hungary)

    2004-12-01

    Background and purpose: to date none of the studies examined the feasibility and efficacy of interstitial high-dose-rate (HDR) brachytherapy in the treatment of carcinoma of the tongue base. Therefore the aim of this study was to contribute to this issue. Patients and methods: between 1992 and 2000 37 patients (mean age 55 years) with T1-4 and NO-3 carcinoma of the base of tongue were presented. Neck dissection was carried out in twelve cases (32%). 30 patients with advanced stage received brachytherapy boost after 50-66.5 Gy (mean, 60 Gy) locoregional external beam irradiation (EBI) and 7 patients with early stage (T1-2, NO) were managed locally with wide tumor excision and sole brachytherapy. 4 of them underwent neck dissection and the others were subjected to 50 Gy regional EBI. The mean dose of boost and sole brachytherapy was 18 Gy and 28 Gy, respectively. Results: the median follow-up time for surviving patients was 51 months. The 7 sole brachytherapy patients are living with no evidence of disease. For patients treated with EBI and brachytherapy boost, the 5-year actuarial rate of local, locoregional recurrence-free and overall survival was 60%, 52% and 46%, respectively. For all patients in univariate analysis larger tumor size (T4 vs. T1-3) was significant negative predictor of local (RR: 7.23) and locoregional control (RR: 3.87), but nodal involvement was not. Delayed soft tissue ulceration and osteoradionecrosis occurred in 4 (13%) EBI and brachytherapy treated patients. None of the sole brachytherapy patients experienced severe late radiation toxicity. Conclusion: EBI combined with interstitial HDR brachytherapy boost result in acceptable local tumor control with low incidence of late side effects in patients with advanced disease. Fractionated sole HDR brachytherapy following tumor excision is a feasible treatment option for patients with early stage cancer and gives excellent local results. (orig.)

  17. Propuesta de un método de ordenador para resolver el ajuste a la ecuación de Zener-Hollomon (Garofalo

    Directory of Open Access Journals (Sweden)

    Rieiro, I.

    1996-10-01

    Full Text Available An integrated computational method to solve the Zener-Hollomon equation has been developed by the authors. This method solves the fitting problem of the equation of Zener-Hollomon for wide ranges of applied stress, strain rate and work temperature by means of the progressive application of three kinds of algorithms. In the first place a program, by means of a reiterated linear regression by planes, allows to get some values that will be later the initial values of a second block of algorithms. It permits also to purify the experimental data set. The second block of algorithms carries out a fitting by nonlinear least squares using a variation of the modified Gauss-Newton method. In the third place a group of programs is chained that permit iterate starting by the solution of the previous program approaching (if it is necessary line by line in R2 until the optimum value is reached. All this with a support of statistical analysis for they determine the accuracy of each step, of the data, of the residuals and of the last fitting reached.

    Se presenta un método de ordenador integrado, desarrollado por los autores, para resolver la ecuación de Zener-Hollomon. Este método resuelve el problema del ajuste de la ecuación de Zener-Hollomon para amplios rangos de tensión aplicada, velocidad de deformación y temperatura de trabajo, mediante la aplicación progresiva de tres tipos de algoritmos. En primer lugar, una regresión reiterada multivariante por planos, para obtener unos valores que serán considerados como iniciales para un segundo bloque de algoritmos, además de depurar la base experimental de datos. El segundo bloque de algoritmos realiza un ajuste por mínimos cuadrados no lineales usando una modificación del método de Gauss-Newton modificado. En tercer lugar se encadena un grupo de programas que permiten iterar a partir de la solución del programa no lineal acercándose (si es preciso por líneas en R2

  18. A GEOGRAFIA DA ACUMULAÇÃO – REFLEXÕES ACERCA DOS TERRITÓRIOS DO TRABALHO ABSTRATO E DA RIQUEZA ABSTRATA

    Directory of Open Access Journals (Sweden)

    Wagnervalter Dutra Júnior

    2012-07-01

    Full Text Available O presente artigo busca analisar as bases territoriais da contradição capital x trabalho, expressa na constituição dos territórios do trabalho abstrato e da riqueza abstrata, constituídos pelos pressupostos espaciais da reprodução ampliada. Os ajustes espaçotemporais que tomaram feição global com o imperialismo são fundamentais para a mundialização do capital e das finanças, apreendendo o trabalho humano nos meandros das escalas circunscritas pelo valor de troca. As formas de mobilidade do capital e do trabalho acabam por atestar a mundialidade da dialética da dependência, centro e periferia são subsumidos à universalização do valor de troca.

  19. DOS cones along atomic chains

    Science.gov (United States)

    Kwapiński, Tomasz

    2017-03-01

    The electron transport properties of a linear atomic chain are studied theoretically within the tight-binding Hamiltonian and the Green’s function method. Variations of the local density of states (DOS) along the chain are investigated. They are crucial in scanning tunnelling experiments and give important insight into the electron transport mechanism and charge distribution inside chains. It is found that depending on the chain parity the local DOS at the Fermi level can form cone-like structures (DOS cones) along the chain. The general condition for the local DOS oscillations is obtained and the linear behaviour of the local density function is confirmed analytically. DOS cones are characterized by a linear decay towards the chain which is in contrast to the propagation properties of charge density waves, end states and Friedel oscillations in one-dimensional systems. We find that DOS cones can appear due to non-resonant electron transport, the spin-orbit scattering or for chains fabricated on a substrate with localized electrons. It is also shown that for imperfect chains (e.g. with a reduced coupling strength between two neighboring sites) a diamond-like structure of the local DOS along the chain appears.

  20. DOS cones along atomic chains

    International Nuclear Information System (INIS)

    Kwapiński, Tomasz

    2017-01-01

    The electron transport properties of a linear atomic chain are studied theoretically within the tight-binding Hamiltonian and the Green’s function method. Variations of the local density of states (DOS) along the chain are investigated. They are crucial in scanning tunnelling experiments and give important insight into the electron transport mechanism and charge distribution inside chains. It is found that depending on the chain parity the local DOS at the Fermi level can form cone-like structures (DOS cones) along the chain. The general condition for the local DOS oscillations is obtained and the linear behaviour of the local density function is confirmed analytically. DOS cones are characterized by a linear decay towards the chain which is in contrast to the propagation properties of charge density waves, end states and Friedel oscillations in one-dimensional systems. We find that DOS cones can appear due to non-resonant electron transport, the spin–orbit scattering or for chains fabricated on a substrate with localized electrons. It is also shown that for imperfect chains (e.g. with a reduced coupling strength between two neighboring sites) a diamond-like structure of the local DOS along the chain appears. (paper)

  1. Dos chalets, en Suecia

    Directory of Open Access Journals (Sweden)

    Erskine, Ralph

    1968-04-01

    Full Text Available Villa Engström, at Sorunda This house, of semi-spheric shape, has besically only one floor level, without basement. However, the guest room and the attic are a kind of second floor within the cupula. This is an experiment, with a view to the possible mass construction of this prototype. The various rooms are grouped in two blocks, one comprising the bedrooms, which are cellular type and of minimum size, and the bathrooms; the other includes the children's room, a living room which extends into the vestibule, and guest room at a higher level. Villa Ström, near Stockholm This house is practically cube shaped, with ample terraces, which are structurally independent of the central volume. A principal aim has been to obtain fine views in all directions, and also to take advantage of the ground slope. This house, of original and competent design, includes indoor gardens which add colour and life to the rooms.Villa Engström, en Sorunda Esta vivienda, que presenta una «forma» semiesferica, es fundamentalmente un edificio de una sola planta, sin sótano; sin embargo, el cuarto de huéspedes y el «ático» forman como una especie de doble planta dentro de la cúpula. Se trata de una experiencia con vistas a una posible fabricación en serie. Las diferentes habitaciones se hallan agrupadas en dos bloques: uno de ellos ocupado por los dormitorios —que son de tipo celular y de tamaño mínimo—, y los cuartos de baño; y el otro que comprende un cuarto para los niños, la sala de estar —unida con el vestíbulo—, y la habitación de los huéspedes en la parte superior. Villa Ström, cerca de Estocolmo La casa es prácticamente un cubo, con terrazas amplias e independientes estructuralmente del volumen principal. En todo caso, ha dominado la doble preocupación de conseguir magníficas vistas hacia todos los alrededores y una adaptación total a la pendiente del terreno. La vivienda se ha resuelto con maestría y originalidad, procurando zonas

  2. OS SACRAMENTAIS, SACRAMENTOS DOS POBRES

    Directory of Open Access Journals (Sweden)

    Victor Codina

    1990-01-01

    Full Text Available Basta ter tido um pouco de experiência pastoral com setores populares, concretamente na América Latina, para constatar a importância dos sacramentais na vida cristã do povo. Além das manifestações de piedade popular que se costuma estudar sob a rubrica de religiosidade popular (peregrinações, festas de padroeiro, procissões..., gostaria de destacar aqui outros elementos mais estreitamente ligados ao mundo dos sacramentos, ainda que não formem parte dos sete sacramentos tridentinos.

  3. The dosimetry of prostate brachytherapy-induced urethral strictures

    International Nuclear Information System (INIS)

    Merrick, Gregory S.; Butler, Wayne M.; Tollenaar, Bryan G.; Galbreath, Robert W.; Lief, Jonathan H.

    2002-01-01

    Purpose: There is a paucity of data regarding the incidence of urethral strictures after prostate brachytherapy. In this study, we evaluate multiple clinical, treatment, and dosimetric parameters to identify factors associated with the development of brachytherapy-induced urethral strictures. Methods and Materials: 425 patients underwent transperineal ultrasound-guided prostate brachytherapy using either 103 Pd or 125 I for clinical T1b/T3a NxM0 (1997, American Joint Committee on Cancer) adenocarcinoma of the prostate gland from April 1995 to October 1999. No patient was lost to follow-up. 221 patients were implanted with 103 Pd and 204 patients with 125 I. The median patient age was 68 years (range 48-81 years). The median follow-up was 35.2 months (range 15-72 months). Follow-up was calculated from the day of implantation. Thirteen patients developed brachytherapy-induced strictures, and all strictures involved the membranous urethra. A control group of 35 patients was rigorously matched to the stricture patients in terms of treatment approach; i.e., choice of isotope, plus or minus radiation therapy, and plus or minus hormonal manipulation. Nine of the 13 stricture patients had detailed Day 0 urethral dosimetry available for review. The apex of the prostate gland and the membranous urethra were defined by CT evaluation. Urethral dosimetry was reported for the prostatic urethra, the apical slice of the prostate gland, and the membranous urethra which was defined as extending 20 mm in length. Results: The 5-year actuarial risk of a urethral stricture was 5.3%, with a median time to development of 26.6 months (range 7.8-44.1 months). Of multiple clinical and treatment parameters evaluated, only the duration of hormonal manipulation (>4 months, p=0.011) was predictive for the development of a urethral stricture. The radiation dose to the membranous urethra was significantly greater in patients with strictures than those without: 97.6%±20.8% vs. 81.0%±19.8% of

  4. High-dose-rate brachytherapy in uterine cervical carcinoma

    International Nuclear Information System (INIS)

    Patel, Firuza D.; Rai, Bhavana; Mallick, Indranil; Sharma, Suresh C.

    2005-01-01

    Purpose: High-dose-rate (HDR) brachytherapy is in wide use for curative treatment of cervical cancer. The American Brachytherapy Society has recommended that the individual fraction size be <7.5 Gy and the range of fractions should be four to eight; however, many fractionation schedules, varying from institution to institution, are in use. We use 9 Gy/fraction of HDR in two to five fractions in patients with carcinoma of the uterine cervix. We found that our results and toxicity were comparable to those reported in the literature and hereby present our experience with this fractionation schedule. Methods and Materials: A total of 121 patients with Stage I-III carcinoma of the uterine cervix were treated with HDR brachytherapy between 1996 and 2000. The total number of patients analyzed was 113. The median patient age was 53 years, and the histopathologic type was squamous cell carcinoma in 93% of patients. The patients were subdivided into Groups 1 and 2. In Group 1, 18 patients with Stage Ib-IIb disease, tumor size <4 cm, and preserved cervical anatomy underwent simultaneous external beam radiotherapy to the pelvis to a dose of 40 Gy in 20 fractions within 4 weeks with central shielding and HDR brachytherapy of 9 Gy/fraction, given weekly, and interdigitated with external beam radiotherapy. The 95 patients in Group 2, who had Stage IIb-IIIb disease underwent external beam radiotherapy to the pelvis to a dose of 46 Gy in 23 fractions within 4.5 weeks followed by two sessions of HDR intracavitary brachytherapy of 9 Gy each given 1 week apart. The follow-up range was 3-7 years (median, 36.4 months). Late toxicity was graded according to the Radiation Therapy Oncology Group criteria. Results: The 5-year actuarial local control and disease-free survival rate was 74.5% and 62.0%, respectively. The actuarial local control rate at 5 years was 100% for Stage I, 80% for Stage II, and 67.2% for Stage III patients. The 5-year actuarial disease-free survival rate was 88.8% for

  5. Interstitial brachytherapy for eyelid carcinoma. Outcome analysis in 60 patients

    Energy Technology Data Exchange (ETDEWEB)

    Krengli, M.; Deantonio, L. [University Hospital ' ' Maggiore della Carita' ' , Division of Radiotherapy, Novara (Italy); University of ' ' Piemonte Orientale' ' , Department of Translational Medicine, Novara (Italy); Masini, L.; Filomeno, A.; Gambaro, G. [University Hospital ' ' Maggiore della Carita' ' , Division of Radiotherapy, Novara (Italy); Comoli, A.M. [University Hospital Maggiore della Carita, Ophthalmology, Novara (Italy); Negri, E. [University Hospital Maggiore della Carita, Medical Physics, Novara (Italy)

    2014-03-15

    Eyelid cancer is a therapeutic challenge due to the cosmetic and functional implications of this anatomical region and the objectives of therapy are tumor control, functional and cosmetic outcome. The present study was performed to analyze local control, toxicity, functional and cosmetic results in patients with eyelid carcinoma treated by interstitial brachytherapy. In this study 60 patients with eyelid carcinoma were treated by interstitial brachytherapy using iridium ({sup 192}Ir) wires with a linear activity of 1.2-1.7 mCi/cm. The prescription dose was 51-70 Gy (mean 65 Gy, median 66 Gy). Of the 60 patients 51 (85.0 %) had received no prior treatment, 4 (6.7 %) had received previous surgery with positive or close margins and 5 (8.3 %) had suffered local recurrence after surgery. Of the tumors 52 (86.7 %) were basal cell carcinoma, 7 (11.7 %) squamous cell carcinoma and 1 (1.7 %) Merkel cell carcinoma. Clinical stage of the 51 previously untreated tumors was 38 T1N0, 12 T2N0 and 1 T3N0. Mean follow-up was 92 months (range 6-253 months). Local control was maintained in 96.7 % of patients. Late effects higher than grade 2 were observed in 3.0 % of cases. Functional and cosmetic outcomes were optimal in 68.4 % of patients. Interstitial brachytherapy for carcinoma of the eyelid can achieve local control, cosmetic and functional results comparable to those of surgery. (orig.) [German] Das Karzinom des Augenlids stellt aufgrund der funktionellen und kosmetischen Beeintraechtigungen dieser anatomischen Region eine therapeutische Herausforderung dar. Ziele der Therapie sind sowohl die Tumorkontrolle als auch ein gutes funktionelles und kosmetisches Ergebnis. Lokale Kontrolle, Toxizitaet sowie funktionelle und kosmetische Ergebnisse bei Patienten mit Karzinom des Augenlids, die mit interstitieller Brachytherapie behandelt wurden, sollten analysiert werden. Sechzig Patienten mit Karzinom des Augenlids wurden mit interstitieller Brachytherapie mit Iridium-192-Draehten

  6. Novel treatment options for nonmelanoma skin cancer: focus on electronic brachytherapy

    Directory of Open Access Journals (Sweden)

    Kasper ME

    2015-11-01

    Full Text Available Michael E Kasper,1,2 Ahmed A Chaudhary3 1Department of Radiation Oncology, Lynn Cancer Institute at Boca Raton Regional Hospital, Boca Raton, 2Charles E. Schmidt College of Medicine, Florida Atlantic University, FL, 3North Main Radiation Oncology, Warren Alpert School of Medicine, Brown University, RI, USA Abstract: Nonmelanoma skin cancer (NMSC is an increasing health care issue in the United States, significantly affecting quality of life and impacting health care costs. Radiotherapy has a long history in the treatment of NMSC. Shortly after the discovery of X-rays and 226Radium, physicians cured patients with NMSC using these new treatments. Both X-ray therapy and brachytherapy have evolved over the years, ultimately delivering higher cure rates and lower toxicity. Electronic brachytherapy for NMSC is based on the technical and clinical data obtained from radionuclide skin surface brachytherapy and the small skin surface applicators developed over the past 25 years. The purpose of this review is to introduce electronic brachytherapy in the context of the history, data, and utilization of traditional radiotherapy and brachytherapy. Keywords: electronic brachytherapy, superficial radiotherapy, skin surface brachytherapy, electron beam therapy, nonmelanoma skin cancer, basal cell carcinoma, squamous cell carcinoma

  7. Estimación de la evapotranspiración de dos cultivares de Gerbera jamesonii en condiciones de hidroponia.

    Directory of Open Access Journals (Sweden)

    Libertad Mascarini

    2003-06-01

    Full Text Available La producción comercial de Gerbera jamesonii para flor de corte ocupa un lugar destacado a nivel mundial. En Argentina la superficie de cultivo bajo invernadero está en aumento y no cubre la demanda del mercado. La introducción de nuevas tecnologías de riego y cultivo que están llevando a cabo los productores, requiere del conocimiento de las necesidades hídricas del cultivo para que el sistema resulte eficiente. El objetivo de este trabajo es caracterizar el consumo hídrico de dos cultivares de Gerbera en hidroponía, mediante el ajuste de modelos de uso corriente, para el área de influencia de la ciudad de Buenos Aires, en el ciclo de primavera. En este ensayo se evalúa el consumo de agua mediante bandejas de drenaje a fin dedeterminar el coeficiente del cultivo (Kc para cada una de las fórmulas empleadas; también secaracteriza el clima del invernadero a fin de hallar los valores de evapotranspiración potencial o de referencia (Eto para esa situación empleando fórmulas de uso corriente y se selecciona la relación entre Eto y Kc que determine la evapotranspiración del cultivo (Etc que mejor se ajuste al consumo medido. No se han detectado diferencias significativas entre ETc y ETo calculada por el método de Penman-Monteith, modificado por FAO, siendo el que mejor se ajusta a la estimación de Eto en las condiciones de invernadero; por el contrario, se han hallado diferencias significativas utilizando el método de Blaney-Criddle. Asimismo, se han detectado diferencias significativas entre la ETc de las dos variedades ensayadas.

  8. Brachytherapy reconstruction using orthogonal scout views from the CT

    International Nuclear Information System (INIS)

    Perez, J.; Lliso, F.; Carmona, V.; Bea, J.; Tormo, A.; Petschen, I.

    1996-01-01

    Introduction: CT assisted brachytherapy planning is demonstrating to have great advantages as external RT planning does. One of the problems we have found in this approach with the conventional gynecological Fletcher applicators is the high amount of artefacts (ovoids with rectal and vessical protections) in the CT slice. We have introduced a reconstruction method based on scout views in order to avoid this problem, allowing us to perform brachytherapy reconstruction completely CT assisted. We use a virtual simulation chain by General Electric Medical Systems. Method and discussion: Two orthogonal scout views (0 and 90 tube positions) are performed. The reconstruction method takes into account the virtual position of the focus and the fact that there is only divergence in the transverse plane. Algorithms developed for sources as well as for reference points localisation (A, B, lymphatic Fletcher trapezoid, pelvic wall, etc.) are presented. This method has the following practical advantages: the porte-cassette is not necessary, the image quality can be improved (it is very helpful in pelvic lateral views that are critical in conventional radiographs), the total time to get the data is smaller than for conventional radiographs (reduction of patient motion effects) and problems that appear in CT-slice based reconstruction in the case of strongly curved intrauterine applicators are avoided. Even though the resolution is smaller than in conventional radiographs it is good enough for brachytherapy. Regarding the CT planning this method presents the interesting feature that the co-ordinate system is the same for the reconstruction process that for the CT-slices set. As the application can be reconstructed from scout views and the doses can be evaluated on CT slices it is easier to correlate the dose values obtained for the traditional points with those provided by the CT information

  9. 'Homogeneity in brachytherapy' - Dummy run experience in Belgium

    International Nuclear Information System (INIS)

    Methords

    1996-01-01

    Purpose: The homogeneity of brachytherapy treatments in Belgium was appreciated through a dummy run with two fictive patients. Materiel and Methods: All members of the Belgian Brachytherapy Board received last year a questionnaire about treatment technique, technical approach, dosimetry and treatment planning, for 2 selected clinical histories. Case 1: T1 G1 NO MO - SCC of the lateral border of the mobile tongue (dimensions: 12x10x5mm). Case 2: T1 G1 NO MO - SCC of the lateral side of the nose (10x12x3mm). Results: 10 members out of 14 from the Belgian Brachytherapy Board returned their questionnaire. Little variation has been observed regarding treatment technique, technical approach (H and N: hairpins or loops, skin: plastic tubes), dose (60-65 Gy), activity of Ir-192 (1-2 mCi/cm), definition of Gross Tumor Volume and dosimetry (Paris System). On the contrary, a large difference was observed in the definition of the Clinical Target Volume and the Treated Volume. Despite of this large difference, the ratio treated volume on clinical target volume was always satisfactory (1,2 for skin cancer - 2 for H and N cancer), indicating that the treatment was well adapted to the Clinical Target Volume in all but 1 instance. Variations of a factor 2 in the dose rate of irradiation were tolerated (40-80 cGy/h). Conclusion: Rigid guidelines are mostly followed by the responders concerning dose, dose prescription and implantation techniques. Large variations are encountered concerning safety margins (Clinical Target definition) and dose rate

  10. Prostate Brachytherapy in Men ≥75 Years of Age

    International Nuclear Information System (INIS)

    Merrick, Gregory S.; Wallner, Kent E.; Galbreath, Robert W.; Butler, Wayne M.; Brammer, Sarah G.; Allen, Zachariah A.; Adamovich, Edward

    2008-01-01

    Purpose: To evaluate cause-specific survival (CSS), biochemical progression-free survival (bPFS), and overall survival (OS) in prostate cancer patients aged ≥75 years undergoing brachytherapy with or without supplemental therapies. Methods and Materials: Between April 1995 and August 2004, 145 consecutive patients aged ≥75 years underwent permanent prostate brachytherapy. Median follow-up was 5.8 years. Biochemical progression-free survival was defined by a prostate-specific antigen level ≤0.40 ng/mL after nadir. Patients with metastatic prostate cancer or hormone-refractory disease without obvious metastases who died of any cause were classified as dead of prostate cancer. All other deaths were attributed to the immediate cause of death. Multiple clinical, treatment, and dosimetric parameters were evaluated for impact on survival. Results: Nine-year CSS, bPFS, and OS rates for the entire cohort were 99.3%, 97.1%, and 64.5%, respectively. None of the evaluated parameters predicted for CSS, whereas bPFS was most closely predicted by percentage positive biopsies. Overall survival and non-cancer deaths were best predicted by tobacco status. Thirty-seven patients have died, with 83.8% of the deaths due to cardiovascular disease (22 patients) or second malignancies (9 patients). To date, only 1 patient (0.7%) has died of metastatic prostate cancer. Conclusions: After brachytherapy, high rates of CSS and bPFS are noted in elderly prostate cancer patients. Overall, approximately 65% of patients are alive at 9 years, with survival most closely related to tobacco status. We believe our results support an aggressive locoregional approach in appropriately selected elderly patients

  11. Dose rate constant and energy spectrum of interstitial brachytherapy sources

    International Nuclear Information System (INIS)

    Chen Zhe; Nath, Ravinder

    2001-01-01

    In the past two years, several new manufacturers have begun to market low-energy interstitial brachytherapy seeds containing 125 I and 103 Pd. Parallel to this development, the National Institute of Standards and Technology (NIST) has implemented a modification to the air-kerma strength (S K ) standard for 125 I seeds and has also established an S K standard for 103 Pd seeds. These events have generated a considerable number of investigations on the determination of the dose rate constants (Λ) of interstitial brachytherapy seeds. The aim of this work is to study the general properties underlying the determination of Λ and to develop a simple method for a quick and accurate estimation of Λ. As the dose rate constant of clinical seeds is defined at a fixed reference point, we postulated that Λ may be calculated by treating the seed as an effective point source when the seed's source strength is specified in S K and its source characteristics are specified by the photon energy spectrum measured in air at the reference point. Using a semi-analytic approach, an analytic expression for Λ was derived for point sources with known photon energy spectra. This approach enabled a systematic study of Λ as a function of energy. Using the measured energy spectra, the calculated Λ for 125 I model 6711 and 6702 seeds and for 192 Ir seed agreed with the AAPM recommended values within ±1%. For the 103 Pd model 200 seed, the agreement was 5% with a recently measured value (within the ±7% experimental uncertainty) and was within 1% with the Monte Carlo simulations. The analytic expression for Λ proposed here can be evaluated using a programmable calculator or a simple spreadsheet and it provides an efficient method for checking the measured dose rate constant for any interstitial brachytherapy seed once the energy spectrum of the seed is known

  12. Three-dimensional tomosynthetic image restoration for brachytherapy source localization

    International Nuclear Information System (INIS)

    Persons, Timothy M.

    2001-01-01

    Tomosynthetic image reconstruction allows for the production of a virtually infinite number of slices from a finite number of projection views of a subject. If the reconstructed image volume is viewed in toto, and the three-dimensional (3D) impulse response is accurately known, then it is possible to solve the inverse problem (deconvolution) using canonical image restoration methods (such as Wiener filtering or solution by conjugate gradient least squares iteration) by extension to three dimensions in either the spatial or the frequency domains. This dissertation presents modified direct and iterative restoration methods for solving the inverse tomosynthetic imaging problem in 3D. The significant blur artifact that is common to tomosynthetic reconstructions is deconvolved by solving for the entire 3D image at once. The 3D impulse response is computed analytically using a fiducial reference schema as realized in a robust, self-calibrating solution to generalized tomosynthesis. 3D modulation transfer function analysis is used to characterize the tomosynthetic resolution of the 3D reconstructions. The relevant clinical application of these methods is 3D imaging for brachytherapy source localization. Conventional localization schemes for brachytherapy implants using orthogonal or stereoscopic projection radiographs suffer from scaling distortions and poor visibility of implanted seeds, resulting in compromised source tracking (reported errors: 2-4 mm) and dosimetric inaccuracy. 3D image reconstruction (using a well-chosen projection sampling scheme) and restoration of a prostate brachytherapy phantom is used for testing. The approaches presented in this work localize source centroids with submillimeter error in two Cartesian dimensions and just over one millimeter error in the third

  13. Novel prostate brachytherapy technique: Improved dosimetric and clinical outcome

    International Nuclear Information System (INIS)

    Nobes, Jenny P.; Khaksar, Sara J.; Hawkins, Maria A.; Cunningham, Melanie J.; Langley, Stephen E.M.; Laing, Robert W.

    2008-01-01

    Purpose: Erectile dysfunction following prostate brachytherapy is reported to be related to dose received by the penile bulb. To minimise this, whilst preserving prostate dosimetry, we have developed a technique for I-125 seed brachytherapy using both stranded seeds and loose seeds delivered with a Mick applicator, and implanted via the sagittal plane on trans-rectal ultrasound. Materials and methods: Post-implant dosimetry and potency rates were compared in 120 potent patients. In Group 1, 60 patients were treated using a conventional technique of seeds implanted in a modified-uniform distribution. From January 2005, a novel technique was developed using stranded seeds peripherally and centrally distributed loose seeds implanted via a Mick applicator (Group 2). The latter technique allows greater flexibility when implanting the seeds at the apex. Each patient was prescribed a minimum peripheral dose of 145 Gy. No patients received external beam radiotherapy or hormone treatment. There was no significant difference in age or pre-implant potency score (mean IIEF-5 score 22.4 vs. 22.6, p = 0.074) between the two groups. Results: The new technique delivers lower penile bulb doses (D 25 as %mPD - Group 1: 61.2 ± 35.7, Group 2: 29.7 ± 16.0, p 50 as %mPD - Group 1: 45.8 ± 26.9, Group 2: 21.4 ± 11.7, p 90 - Group 1: 147 Gy ± 21.1, Group 2: 155 Gy ± 16.7, p = 0.03). At 2 years, the potency rate was also improved: Group 1: 61.7%; Group 2: 83.3% (p = 0.008). Conclusions: In this study, the novel brachytherapy technique using both peripheral stranded seeds and central loose seeds delivered via a Mick applicator results in a lower penile bulb dose whilst improving prostate dosimetry, and may achieve higher potency rates

  14. Dosimetric equivalence of nonstandard HDR brachytherapy catheter patterns

    International Nuclear Information System (INIS)

    Cunha, J. A. M.; Hsu, I-C.; Pouliot, J.

    2009-01-01

    Purpose: To determine whether alternative high dose rate prostate brachytherapy catheter patterns can result in similar or improved dose distributions while providing better access and reducing trauma. Materials and Methods: Standard prostate cancer high dose rate brachytherapy uses a regular grid of parallel needle positions to guide the catheter insertion. This geometry does not easily allow the physician to avoid piercing the critical structures near the penile bulb nor does it provide position flexibility in the case of pubic arch interference. This study used CT datasets with 3 mm slice spacing from ten previously treated patients and digitized new catheters following three hypothetical catheter patterns: conical, bi-conical, and fireworks. The conical patterns were used to accommodate a robotic delivery using a single entry point. The bi-conical and fireworks patterns were specifically designed to avoid the critical structures near the penile bulb. For each catheter distribution, a plan was optimized with the inverse planning algorithm, IPSA, and compared with the plan used for treatment. Irrelevant of catheter geometry, a plan must fulfill the RTOG-0321 dose criteria for target dose coverage (V 100 Prostate >90%) and organ-at-risk dose sparing (V 75 Bladder 75 Rectum 125 Urethra <<1 cc). Results: The three nonstandard catheter patterns used 16 nonparallel, straight divergent catheters, with entry points in the perineum. Thirty plans from ten patients with prostate sizes ranging from 26 to 89 cc were optimized. All nonstandard patterns fulfilled the RTOG criteria when the clinical plan did. In some cases, the dose distribution was improved by better sparing the organs-at-risk. Conclusion: Alternative catheter patterns can provide the physician with additional ways to treat patients previously considered unsuited for brachytherapy treatment (pubic arch interference) and facilitate robotic guidance of catheter insertion. In addition, alternative catheter

  15. MO-E-BRD-02: Accelerated Partial Breast Irradiation in Brachytherapy: Is Shorter Better?

    International Nuclear Information System (INIS)

    Todor, D.

    2015-01-01

    Is Non-invasive Image-Guided Breast Brachytherapy Good? – Jess Hiatt, MS Non-invasive Image-Guided Breast Brachytherapy (NIBB) is an emerging therapy for breast boost treatments as well as Accelerated Partial Breast Irradiation (APBI) using HDR surface breast brachytherapy. NIBB allows for smaller treatment volumes while maintaining optimal target coverage. Considering the real-time image-guidance and immobilization provided by the NIBB modality, minimal margins around the target tissue are necessary. Accelerated Partial Breast Irradiation in brachytherapy: is shorter better? - Dorin Todor, PhD VCU A review of balloon and strut devices will be provided together with the origins of APBI: the interstitial multi-catheter implant. A dosimetric and radiobiological perspective will help point out the evolution in breast brachytherapy, both in terms of devices and the protocols/clinical trials under which these devices are used. Improvements in imaging, delivery modalities and convenience are among the factors driving the ultrashort fractionation schedules but our understanding of both local control and toxicities associated with various treatments is lagging. A comparison between various schedules, from a radiobiological perspective, will be given together with a critical analysis of the issues. to review and understand the evolution and development of APBI using brachytherapy methods to understand the basis and limitations of radio-biological ‘equivalence’ between fractionation schedules to review commonly used and proposed fractionation schedules Intra-operative breast brachytherapy: Is one stop shopping best?- Bruce Libby, PhD. University of Virginia A review of intraoperative breast brachytherapy will be presented, including the Targit-A and other trials that have used electronic brachytherapy. More modern approaches, in which the lumpectomy procedure is integrated into an APBI workflow, will also be discussed. Learning Objectives: To review past and current

  16. Endovascular brachytherapy prevents restenosis after femoropopliteal angioplasty: results of the Vienna-3 randomised multicenter study

    International Nuclear Information System (INIS)

    Pokrajac, Boris; Poetter, Richard; Wolfram, Roswitha M.; Budinsky, Alexandra C.; Kirisits, Christian; Lileg, Brigitte; Mendel, Helmuth; Sabeti, Schila; Schmid, Rainer; Minar, Erich

    2005-01-01

    Background and purpose: The aim of the trial was to investigate the effect of Iridium-192 gamma endovascular brachytherapy on reduction of restenosis after femoropopliteal angioplasty. Patients and methods: Between Oct, 1998 and Jul, 2001 a total of 134 patients have been randomized after successful angioplasty to brachytherapy or sham irradiation in a prospective, randomized, multicenter, double blind controlled trial. Patients with de novo lesion of at least 5 cm or recurrent lesion of any length after prior angioplasty have been enrolled. Brachytherapy was performed with 7 F centering catheter. Mean lesion length was 9.1 cm (1.5-25 cm) and mean intervention length 13.6 cm (4-27.5 cm) in brachytherapy cohort. Results: In placebo cohort mean lesion length was 10.3 cm (2-25 cm) and mean intervention length 14.1 cm (2-29 cm). A dose of 18 Gy was prescribed 2 mm from the surface of centering balloons. Analyzed (based on angiography) on intention to treat basis the binary restenosis rate at 12 months was 41.7% (28/67) in brachytherapy cohort and 67.1% (45/67) in placebo cohort (χ 2 test, P 30% residual stenosis after angioplasty) have been 23.4% in the brachytherapy and 53.3% in the placebo group (P<0.05), respectively. The cumulative patency rates after 24 months on intention to treat analysis were 54% in the brachytherapy and 27% in the placebo group (P<0.005). Corresponding data for as treated analysis were 77% in the brachytherapy and 39% in the placebo group (P<0.001). Late thrombosis was not seen. Conclusions: Significant reduction of restenosis rate was obtained with endovascular gamma brachytherapy after femoropopliteal angioplasty

  17. MO-E-BRD-02: Accelerated Partial Breast Irradiation in Brachytherapy: Is Shorter Better?

    Energy Technology Data Exchange (ETDEWEB)

    Todor, D. [Virginia Commonwealth University (United States)

    2015-06-15

    Is Non-invasive Image-Guided Breast Brachytherapy Good? – Jess Hiatt, MS Non-invasive Image-Guided Breast Brachytherapy (NIBB) is an emerging therapy for breast boost treatments as well as Accelerated Partial Breast Irradiation (APBI) using HDR surface breast brachytherapy. NIBB allows for smaller treatment volumes while maintaining optimal target coverage. Considering the real-time image-guidance and immobilization provided by the NIBB modality, minimal margins around the target tissue are necessary. Accelerated Partial Breast Irradiation in brachytherapy: is shorter better? - Dorin Todor, PhD VCU A review of balloon and strut devices will be provided together with the origins of APBI: the interstitial multi-catheter implant. A dosimetric and radiobiological perspective will help point out the evolution in breast brachytherapy, both in terms of devices and the protocols/clinical trials under which these devices are used. Improvements in imaging, delivery modalities and convenience are among the factors driving the ultrashort fractionation schedules but our understanding of both local control and toxicities associated with various treatments is lagging. A comparison between various schedules, from a radiobiological perspective, will be given together with a critical analysis of the issues. to review and understand the evolution and development of APBI using brachytherapy methods to understand the basis and limitations of radio-biological ‘equivalence’ between fractionation schedules to review commonly used and proposed fractionation schedules Intra-operative breast brachytherapy: Is one stop shopping best?- Bruce Libby, PhD. University of Virginia A review of intraoperative breast brachytherapy will be presented, including the Targit-A and other trials that have used electronic brachytherapy. More modern approaches, in which the lumpectomy procedure is integrated into an APBI workflow, will also be discussed. Learning Objectives: To review past and current

  18. MO-E-BRD-03: Intra-Operative Breast Brachytherapy: Is One Stop Shopping Best?

    International Nuclear Information System (INIS)

    Libby, B.

    2015-01-01

    Is Non-invasive Image-Guided Breast Brachytherapy Good? – Jess Hiatt, MS Non-invasive Image-Guided Breast Brachytherapy (NIBB) is an emerging therapy for breast boost treatments as well as Accelerated Partial Breast Irradiation (APBI) using HDR surface breast brachytherapy. NIBB allows for smaller treatment volumes while maintaining optimal target coverage. Considering the real-time image-guidance and immobilization provided by the NIBB modality, minimal margins around the target tissue are necessary. Accelerated Partial Breast Irradiation in brachytherapy: is shorter better? - Dorin Todor, PhD VCU A review of balloon and strut devices will be provided together with the origins of APBI: the interstitial multi-catheter implant. A dosimetric and radiobiological perspective will help point out the evolution in breast brachytherapy, both in terms of devices and the protocols/clinical trials under which these devices are used. Improvements in imaging, delivery modalities and convenience are among the factors driving the ultrashort fractionation schedules but our understanding of both local control and toxicities associated with various treatments is lagging. A comparison between various schedules, from a radiobiological perspective, will be given together with a critical analysis of the issues. to review and understand the evolution and development of APBI using brachytherapy methods to understand the basis and limitations of radio-biological ‘equivalence’ between fractionation schedules to review commonly used and proposed fractionation schedules Intra-operative breast brachytherapy: Is one stop shopping best?- Bruce Libby, PhD. University of Virginia A review of intraoperative breast brachytherapy will be presented, including the Targit-A and other trials that have used electronic brachytherapy. More modern approaches, in which the lumpectomy procedure is integrated into an APBI workflow, will also be discussed. Learning Objectives: To review past and current

  19. Treatment of soft-tissue sarcomas of children through brachytherapy

    International Nuclear Information System (INIS)

    Ladeia, F.T.; Novaes, P.E.R.S.; Pereira, A.J.; Peres, O.; Camargo, B.; Bianchi, A.

    1988-01-01

    Twelve children were treated from January 1979 to June 1986 and the age range was three months to 14 years. Ten patients had implanted sources in the tumour tissue and two had a surface radioactive applicator. Eleven children had local control of disease, four with long term survival (longer than 50 months), good cosmetic and functional results and seven with shorter follow-up (minimal 17 months). Only one local relapse occurred in the irradiated area, five months after treatment. Brachytherapy may be an useful modality of treatment in pediatric oncology making possible the reduction of external therapy dose, minimizing the late effects of treatment, with better survival. (author)

  20. Three-dimensional dosimetry in brachytherapy: A MAGAT study

    Energy Technology Data Exchange (ETDEWEB)

    Lin, M.-H. [Department of Family Medicine and Physical Check-up Center, Tainan Hospital Department of Health, Executive Yuan, Taiwan (China); Department of Nursing, National Tainan Institute of Nursing, Taiwan (China); Huang, T.-C. [Department of Biomedical Imaging and Radiological Science, China Medical University, Taiwan (China); Kao, M.-J. [Department of Family Medicine and Physical Check-up Center, Tainan Hospital Department of Health, Executive Yuan, Taiwan (China); Department of Nursing, National Tainan Institute of Nursing, Taiwan (China); Wu, Jay [Department of Radiological Technology, Central Taiwan University of Science and Technology, Taiwan (China); Chen, C.-L. [Department of Medical Imaging and Radiological Sciences, Chung Shan Medical University, No. 110, Sec. 1, Chien-Kuo N. Road, South District, Taichung 402, Taiwan (China); Wu, T.-H. [Department of Medical Imaging and Radiological Sciences, Chung Shan Medical University, No. 110, Sec. 1, Chien-Kuo N. Road, South District, Taichung 402, Taiwan (China)], E-mail: tung@csmu.edu.tw

    2009-07-15

    This study is to evaluate the influence of using different matrix size of smoothing filter for image post-processing and various slice thickness during MR imaging on dose estimation in Ir-192 HDR brachytherapy via normoxic polymer gel dosimeter. Our results show its sensitive nature in gel dosimeter while changing these parameters, among which the combination of 2 mm slice thickness of MR images and [5x5] smoothing filter are considered the optimal parameters to provide accurate dose estimations and isodose curves.

  1. Three-dimensional dosimetry in brachytherapy: A MAGAT study

    International Nuclear Information System (INIS)

    Lin, M.-H.; Huang, T.-C.; Kao, M.-J.; Wu, Jay; Chen, C.-L.; Wu, T.-H.

    2009-01-01

    This study is to evaluate the influence of using different matrix size of smoothing filter for image post-processing and various slice thickness during MR imaging on dose estimation in Ir-192 HDR brachytherapy via normoxic polymer gel dosimeter. Our results show its sensitive nature in gel dosimeter while changing these parameters, among which the combination of 2 mm slice thickness of MR images and [5x5] smoothing filter are considered the optimal parameters to provide accurate dose estimations and isodose curves.

  2. Monte Carlo simulation of MOSFET dosimeter for brachytherapy sources

    International Nuclear Information System (INIS)

    Suchitra, G.; Bharanidharan, G.; Manigandan, D.; Aruna, P.; Ganesan, S.; Subbaiah, K.V.

    2008-01-01

    In vivo patient dose verification is considered to be an important part of quality assurance in radiotherapy, as there may be uncertainty between the prescribed dose and the dose actually delivered to the patients. A dose estimator method was used to calculate the dose in the extremely thin sensitive volume. This work shows the response of MOSFET detector for various brachytherapy sources at various experimental condition and the results were compared with the earlier published values. The details of computations and the results are discussed

  3. Spectroscopic characterization of low dose rate brachytherapy sources

    Science.gov (United States)

    Beach, Stephen M.

    The low dose rate (LDR) brachytherapy seeds employed in permanent radioactive-source implant treatments usually use one of two radionuclides, 125I or 103Pd. The theoretically expected source spectroscopic output from these sources can be obtained via Monte Carlo calculation based upon seed dimensions and materials as well as the bare-source photon emissions for that specific radionuclide. However the discrepancies resulting from inconsistent manufacturing of sources in comparison to each other within model groups and simplified Monte Carlo calculational geometries ultimately result in undesirably large uncertainties in the Monte Carlo calculated values. This dissertation describes experimentally attained spectroscopic outputs of the clinically used brachytherapy sources in air and in liquid water. Such knowledge can then be applied to characterize these sources by a more fundamental and metro logically-pure classification, that of energy-based dosimetry. The spectroscopic results contained within this dissertation can be utilized in the verification and benchmarking of Monte Carlo calculational models of these brachytherapy sources. This body of work was undertaken to establish a usable spectroscopy system and analysis methods for the meaningful study of LDR brachytherapy seeds. The development of a correction algorithm and the analysis of the resultant spectroscopic measurements are presented. The characterization of the spectrometer and the subsequent deconvolution of the measured spectrum to obtain the true spectrum free of any perturbations caused by the spectrometer itself is an important contribution of this work. The approach of spectroscopic deconvolution that was applied in this work is derived in detail and it is applied to the physical measurements. In addition, the spectroscopically based analogs to the LDR dosimetry parameters that are currently employed are detailed, as well as the development of the theory and measurement methods to arrive at these

  4. HIGH-DOSE RATE BRACHYTHERAPY IN CARCINOMA CERVIX STAGE IIIB

    Directory of Open Access Journals (Sweden)

    Sathya Maruthavanan

    2016-07-01

    Full Text Available INTRODUCTION Radiotherapy is the standard treatment in locally advanced (IIB-IVA and early inoperable cases. The current standard of practice with curable intent is concurrent chemoradiation in which intracavitary brachytherapy is an integral component of radiotherapy. This study aims at assessing the efficacy of HDR ICBT (High-dose rate intracavitary brachytherapy in terms local response, normal tissue reactions, and feasibility. METHODS AND MATERIALS A total of 20 patients of stage IIIB cancer of the uterine cervix were enrolled in the study and were planned to receive concurrent chemotherapy weekly along with EBRT (external beam radiotherapy to a dose of 50 Gy/25 Fr. Suitability for ICBT was assessed at 40 Gy/20 Fr. 6/20 patients were suitable at 40 Gy and received HDR ICBT with a dose of 5.5 Gy to point A in 4 sessions (5.5 Gy/4 Fr. The remaining 14/20 patients completed 50 Gy and received HDR ICBT with a dose of 6 Gy to point A in 3 sessions (6 Gy/3 Fr. RESULTS A total of 66 intracavitary applications were done and only one application required dose modification due to high bladder dose, the pelvic control rate was 85% (17/20. 10% (2/20 had stable disease and 5% (1/20 had progressive disease at one year of follow up. When toxicity was considered only 15% developed grade I and grade II rectal complications. Patient compliance and acceptability was 100%. Patients were very comfortable with the short treatment time as compared with patients on LDR ICBT (low-dose rate intracavitary brachytherapy treatment interviewed during the same period. CONCLUSION This study proves that HDR brachytherapy is efficacious and feasible in carcinoma of cervix stage IIIB. It also proves that good dose distribution can be achieved with HDR intracavitary facility by the use of dose optimization. The short treatment time in HDR ICBT makes it possible to maintain this optimised dose distribution throughout the treatment providing a gain in the therapeutic ratio and

  5. Experience of the first application of HDR brachytherapy in nasopharynx

    International Nuclear Information System (INIS)

    Vega Hernandez, Manuel I.; Alfonso Laguardia, Rodolfo; Silvestre Patallo, Ileana; Roca Muchuli, Carlos; Garcia Heredia, Gilda

    2006-01-01

    A research was made by applying boost on the area of the nasopharynx relapse with high dose rate (HDR) in a diagnosis of nasopharynx carcinoma previously treated with telecobalt therapy, at a dose of 70 Gy. There was persistence of the injury. Three sessions were planned, with consecutive fractions of 6.5 Gy in 15 days, with optimization, using a personal mould of autopolymerizable acrylic. The successful possibility to apply the high rate modern brachytherapy was reaffirmed, as a treatment complementary to teletherapy in case of persistence or relapse. A Micro Selectron HDR equipment was used

  6. Automatic analysis of intrinsic positional verification films brachytherapy using MATLAB

    International Nuclear Information System (INIS)

    Quiros Higueras, J. D.; Marco Blancas, N. de; Ruiz Rodriguez, J. C.

    2011-01-01

    One of the essential tests in quality control of brachytherapy equipment is verification auto load intrinsic positional radioactive source. A classic method for evaluation is the use of x-ray film and measuring the distance between the marks left by autoradiography of the source with respect to a reference. In our center has developed an automated method of measurement by the radiochromic film scanning and implementation of a macro developed in Matlab, in order to optimize time and reduce uncertainty in the measurement. The purpose of this paper is to describe the method developed, assess their uncertainty and quantify their advantages over the manual method. (Author)

  7. Matlab Tools: An Alternative to Planning Systems in Brachytherapy Treatments

    International Nuclear Information System (INIS)

    Herrera, Higmar; Rodriguez, Mercedes; Rodriguez, Miguel

    2006-01-01

    This work proposes the use of the Matlab environment to obtain the treatment dose based on the reported data by Krishnaswamy and Liu et al. The comparison with reported measurements is showed for the Amersham source model. For the 3M source model, measurements with TLDs and a Monte Carlo simulation are compared to the data obtained by Matlab. The difference for the Amersham model is well under the 15% recommended by the IAEA and for the 3M model, although the difference is greater, the results are consistent. The good agreement to the reported data allows the Matlab calculations to be used in daily brachytherapy treatments

  8. Argon plasma coagulation for rectal bleeding after prostate brachytherapy

    International Nuclear Information System (INIS)

    Smith, Stephen; Wallner, Kent; Dominitz, Jason A.; Han, Ben; True, Lawrence; Sutlief, Steven; Billingsley, Kevin

    2001-01-01

    Purpose: To better define the efficacy and safety of argon plasma coagulation (APC), specifically for brachytherapy-related proctitis, we reviewed the clinical course of 7 patients treated for persistent rectal bleeding. Approximately 2-10% of prostate cancer patients treated with 125 I or 103 Pd brachytherapy will develop radiation proctitis. The optimum treatment for patients with persistent bleeding is unclear from the paucity of available data. Prior reports lack specific dosimetric information, and patients with widely divergent forms of radiation were grouped together in the analyses. Methods and Materials: Seven patients were treated with APC at the Veterans Affairs Puget Sound Health Care System and the University of Washington from 1997 to 1999 for persistent rectal bleeding due to prostate brachytherapy-related proctitis. Four patients received supplemental external beam radiation, delivered by a four-field technique. A single gastroenterologist at the Veterans Affairs Puget Sound Health Care System treated 6 of the 7 patients. If the degree of proctitis was limited, all sites of active bleeding were coagulated in symptomatic patients. An argon plasma coagulator electrosurgical system was used to administer treatments every 4-8 weeks as needed. The argon gas flow was set at 1.6 L/min, with an electrical power setting of 40-45 W. Results: The rectal V100 (the total rectal volume, including the lumen, receiving the prescription dose or greater) for the 7 patients ranged from 0.13 to 4.61 cc. Rectal bleeding was first noticed 3-18 months after implantation. APC (range 1-3 sessions) was performed 9-22 months after implantation. Five patients had complete resolution of their bleeding, usually within days of completing APC. Two patients had only partial relief from bleeding, but declined additional APC therapy. No patient developed clinically evident progressive rectal wall abnormalities after APC, (post-APC follow-up range 4-13 months). Conclusions: Most

  9. Verification of the calculation program for brachytherapy planning system of high dose rate (PLATO)

    International Nuclear Information System (INIS)

    Almansa, J.; Alaman, C.; Perez-Alija, J.; Herrero, C.; Real, R. del; Ososrio, J. L.

    2011-01-01

    In our treatments are performed brachytherapy high dose rate since 2007. The procedures performed include gynecological intracavitary treatment and interstitial. The treatments are performed with a source of Ir-192 activity between 5 and 10 Ci such that small variations in treatment times can cause damage to the patient. In addition the Royal Decree 1566/1998 on Quality Criteria in radiotherapy establishes the need to verify the monitor units or treatment time in radiotherapy and brachytherapy. All this justifies the existence of a redundant system for brachytherapy dose calculation that can reveal any abnormality is present.

  10. Importance of brachytherapy technique in the management of primary carcinoma of the vagina

    International Nuclear Information System (INIS)

    Stock, R.G.; Mychalczak, B.; Armstrong, J.G.; Hoskins, W.; Harrison, L.B.

    1991-01-01

    Primary vaginal carcinoma is a rare malignancy. There is little information regarding the optimal treatment. Management has primarily been with external-beam radiation therapy and brachytherapy. This paper examines the importance of brachytherapy and the significance of its techniques in the treatment of this disease. Brachytherapy plays an important part in the management of primary vaginal carcinoma. External-beam radiation therapy alone is not an adequate treatment for this disease. For stages II and III disease, there is a trend toward improved disease-free survival with the use of a temporary interstitial implant compared to an intracavitary application

  11. Place of the brachytherapy in the therapeutic strategy of rhabdomyosarcomas of the nasogenian groove of children

    International Nuclear Information System (INIS)

    Breton-Callu, C.; Haie-Meder, C.; Oberlin, O.; Delapierre, M.; Gerbaulet, A.

    2000-01-01

    The brachytherapy in the treatment of rhabdomyosarcomas of the nasogenian groove has to be discussed when it exists a residual tumor after an initial chemotherapy and leads to good results, in term of local control. An advantage of the brachytherapy in comparison with external irradiation, in the treatment of children tumors, is the small size of the treated volume, that allows to decrease the aftereffects incidence. The brachytherapy comes in the frame of a therapeutic needing a multidisciplinary approach and a cooperation between surgeons, brachy-therapists and onco-pediatricians. (N.C.)

  12. LDR vs. HDR brachytherapy for localized prostate cancer: the view from radiobiological models.

    Science.gov (United States)

    King, Christopher R

    2002-01-01

    Permanent LDR brachytherapy and temporary HDR brachytherapy are competitive techniques for clinically localized prostate radiotherapy. Although a randomized trial will likely never be conducted comparing these two forms of brachytherapy, a comparative radiobiological modeling analysis proves useful in understanding some of their intrinsic differences, several of which could be exploited to improve outcomes. Radiobiological models based upon the linear quadratic equations are presented for fractionated external beam, fractionated (192)Ir HDR brachytherapy, and (125)I and (103)Pd LDR brachytherapy. These models incorporate the dose heterogeneities present in brachytherapy based upon patient-derived dose volume histograms (DVH) as well as tumor doubling times and repair kinetics. Radiobiological parameters are normalized to correspond to three accepted clinical risk factors based upon T-stage, PSA, and Gleason score to compare models with clinical series. Tumor control probabilities (TCP) for LDR and HDR brachytherapy (as monotherapy or combined with external beam) are compared with clinical bNED survival rates. Predictions are made for dose escalation with HDR brachytherapy regimens. Model predictions for dose escalation with external beam agree with clinical data and validate the models and their underlying assumptions. Both LDR and HDR brachytherapy achieve superior tumor control when compared with external beam at conventional doses (LDR brachytherapy as boost achieves superior tumor control than when used as monotherapy. Stage for stage, both LDR and current HDR regimens achieve similar tumor control rates, in agreement with current clinical data. HDR monotherapy with large-dose fraction sizes might achieve superior tumor control compared with LDR, especially if prostate cancer possesses a high sensitivity to dose fractionation (i.e., if the alpha/beta ratio is low). Radiobiological models support the current clinical evidence for equivalent outcomes in localized

  13. Comparison of single-incision mini-slings (Ajust) and standard transobturator midurethral slings (Align) in the management of female stress urinary incontinence: A 1-year follow-up.

    Science.gov (United States)

    Chang, Chia-Pei; Chang, Wen-Hsun; Hsu, Yen-Mei; Chen, Yi-Jen; Wen, Kuo-Chang; Chao, Kuan-Chong; Yen, Ming-Shyen; Horng, Huann-Cheng; Wang, Peng-Hui

    2015-12-01

    To investigate the effectiveness and safety of a new single-incision mini-sling (SIMS)-Ajust-compared with the standard transobturator midurethral sling (SMUS)-Align-for the treatment of female stress urinary incontinence (SUI). A retrospective cohort study was conducted between January 1, 2010 and August 31, 2012. Women with SUI who underwent either SMUS-Align or SIMS-Ajust were recruited. The primary outcomes included operation time, estimated operative blood loss, postoperative pain, and complications. The secondary outcomes included subjective and objective success, defined as an International Consultation on Incontinence Questionnaire (ICIQ) score of 0 or improvement as felt by the patient and a long-term complication, such as dyspareunia and mesh erosion after 6 months and 12 months of follow-up. A total of 136 patients were enrolled, including 76 receiving SMUS-Align and 60 receiving SIMS-Ajust. Baseline characteristics of the patients in both groups were similar, without a statistically significant difference. Primary outcomes between both groups were similar, except that women treated with SIMS-Ajust had statistically significantly shorter operation time (p = 0.003), less intent to treat (p < 0.05), and earlier postoperative discharge (p = 0.001) than women treated with SMUS-Align. Secondary outcomes were similar without a significant difference between the two groups (93% vs. 88% success rate in each group). Our results showed that SIMS-Ajust was not inferior to SMUS-Align with respect to success rate, and might have a slight advantage in early discharge. A long-term follow-up or prospective study is needed to confirm the above findings. Copyright © 2015. Published by Elsevier B.V.

  14. Setting efficiency indicators for center pivots Ajuste de indicadores de eficiência para pivôs centrais

    Directory of Open Access Journals (Sweden)

    Ricardo L. Schons

    2012-06-01

    Full Text Available In this study, it was discussed the efficiency criteria in each of the elements that compose a central pivot, and this analysis was applied to two sets of systems located in regions of Cruz Alta and Santo Augusto, state of Rio Grande do Sul, Brazil. The methodology used combines water and energy assessment through an indicator called Normalized Specific Consumption in Irrigation (C ENI, allowing thus a comparison between equipment and projects. The C ENI in Cruz Alta region showed 72% of the equipment above the standard (8.68 kWh mm-1 ha-1 100m-1, and in Santo Augusto region 64.28% with consumption above the standard. The mean irrigation efficiency for Cruz Alta region was 29.85%, with standard deviation of 5.41%, and for Santo Augusto region, it was 29.02%, with standard deviation of 5.15%.Neste trabalho, são discutidos critérios de eficiência em cada um dos elementos que compõem um pivô central, sendo esta análise aplicada a dois conjuntos de sistemas localizados, nas regiões de Cruz Alta e Santo Augusto, Rio Grande do Sul. A metodologia utilizada associa as avaliações hídrica e energética por meio de um indicador denominado Consumo Específico Normalizado na Irrigação (C ENI, possibilitando, desta forma, uma comparação entre equipamentos e entre projetos. O C ENI na região de Cruz Alta apresentou 72% dos equipamentos acima do padrão (8,68 kWh mm-1 ha-1 100m-1, e na região de Santo Augusto, 64,28% com o consumo acima do padrão. A eficiência de irrigação média para a região de Cruz Alta foi de 29,85%, com desvio-padrão de 5,41%; e para a Região de Santo Augusto foi de 29,02%, com desvio padrão de 5,15%.

  15. Brachytherapy for cervix cancer: low-dose rate or high-dose rate brachytherapy – a meta-analysis of clinical trials

    Directory of Open Access Journals (Sweden)

    Stefano Eduardo J

    2009-04-01

    Full Text Available Abstract Background The literature supporting high-dose rate brachytherapy (HDR in the treatment of cervical carcinoma derives primarily from retrospective series. However, controversy still persists regarding the efficacy and safety of HDR brachytherapy compared to low-dose rate (LDR brachytherapy, in particular, due to inadequate tumor coverage for stage III patients. Whether LDR or HDR brachytherapy produces better results for these patients in terms of survival rate, local control rate and the treatment complications remain controversial. Methods A meta-analysis of RCT was performed comparing LDR to HDR brachytherapy for cervix cancer treated for radiotherapy alone. The MEDLINE, EMBASE, CANCERLIT and Cochrane Library databases, as well as abstracts published in the annual proceedings were systematically searched. We assessed methodological quality for each outcome by grading the quality of evidence using the Grading of Recommendations Assessment, Development and Evaluation (GRADE methodology. We used "recommend" for strong recommendations, and "suggest" for weak recommendations. Results Pooled results from five randomized trials (2,065 patients of HDR brachytherapy in cervix cancer showed no significant increase of mortality (p = 0.52, local recurrence (p = 0.68, or late complications (rectal; p = 0.7, bladder; p = 0.95 or small intestine; p = 0.06 rates as compared to LDR brachytherapy. In the subgroup analysis no difference was observed for overall mortality and local recurrence in patients with clinical stages I, II and III. The quality of evidence was low for mortality and local recurrence in patients with clinical stage I, and moderate for other clinical stages. Conclusion Our meta-analysis shows that there are no differences between HDR and LDR for overall survival, local recurrence and late complications for clinical stages I, II and III. By means of the GRADE system, we recommend the use of HDR for all clinical stages of cervix

  16. Brachytherapy for cervix cancer: low-dose rate or high-dose rate brachytherapy – a meta-analysis of clinical trials

    Science.gov (United States)

    Viani, Gustavo A; Manta, Gustavo B; Stefano, Eduardo J; de Fendi, Ligia I

    2009-01-01

    Background The literature supporting high-dose rate brachytherapy (HDR) in the treatment of cervical carcinoma derives primarily from retrospective series. However, controversy still persists regarding the efficacy and safety of HDR brachytherapy compared to low-dose rate (LDR) brachytherapy, in particular, due to inadequate tumor coverage for stage III patients. Whether LDR or HDR brachytherapy produces better results for these patients in terms of survival rate, local control rate and the treatment complications remain controversial. Methods A meta-analysis of RCT was performed comparing LDR to HDR brachytherapy for cervix cancer treated for radiotherapy alone. The MEDLINE, EMBASE, CANCERLIT and Cochrane Library databases, as well as abstracts published in the annual proceedings were systematically searched. We assessed methodological quality for each outcome by grading the quality of evidence using the Grading of Recommendations Assessment, Development and Evaluation (GRADE) methodology. We used "recommend" for strong recommendations, and "suggest" for weak recommendations. Results Pooled results from five randomized trials (2,065 patients) of HDR brachytherapy in cervix cancer showed no significant increase of mortality (p = 0.52), local recurrence (p = 0.68), or late complications (rectal; p = 0.7, bladder; p = 0.95 or small intestine; p = 0.06) rates as compared to LDR brachytherapy. In the subgroup analysis no difference was observed for overall mortality and local recurrence in patients with clinical stages I, II and III. The quality of evidence was low for mortality and local recurrence in patients with clinical stage I, and moderate for other clinical stages. Conclusion Our meta-analysis shows that there are no differences between HDR and LDR for overall survival, local recurrence and late complications for clinical stages I, II and III. By means of the GRADE system, we recommend the use of HDR for all clinical stages of cervix cancer. PMID:19344527

  17. The role of brachytherapy in the definitive management of prostate cancer; Place de la curietherapie dans le traitement du cancer prostatique localise

    Energy Technology Data Exchange (ETDEWEB)

    Crook, J. [British Columbia Cancer Agency, Center for the Southern Interior, 399, Royal Avenue, Kelowna, British Columbia, V1Y 5L33 (Canada)

    2011-06-15

    Over the past two decades, brachytherapy has played an ever expanding role in the definitive radiotherapy of prostate cancer. Brachytherapy surpasses external beam radiotherapy in its ability to deliver intense intra-prostatic dose escalation. Although initially low dose rate permanent seed brachytherapy was favored for favorable risk prostate cancers, and high dose rate temporary brachytherapy for intermediate and advanced disease, both types of brachytherapy now have a place across all the risk groups of localized prostate cancer. This article will review indications and patient selection, planning and technical aspects, toxicity and efficacy for both low and high dose rate prostate brachytherapy. (author)

  18. O Arranjo Produtivo Local da Apicultura de Mato Grosso: Evolução Recente e Necessidade de Ajustes

    Directory of Open Access Journals (Sweden)

    Dilamar Dallemole

    2011-06-01

    Full Text Available Normal 0 21 false false false PT-BR X-NONE X-NONE Este estudo tem como escopo central avaliar as ações desencadeadas pelas instituições locais junto ao APL da Apicultura de Mato Grosso, avaliando se estão em consonância com o conceito e a metodologia desenvolvida pela Rede de Pesquisa em Sistemas e Arranjos Produtivos e Inovativos Locais (REDESIST. Ainda, visa delimitar os espaços onde a atividade apresenta-se especializada e se estes locais coincidem com a delimitação territorial do arranjo realizada pelo SEBRAE. Para isso, foram utilizados dados do Instituto Brasileiro de Geografia e Estatística (IBGE, para estimar o Índice de Concentração Normalizado (ICN, capaz de determinar a base territorial que realmente possui alguma especialização na referida atividade. Tal procedimento, também, revelou que apenas 43% dos municípios apoiados possuem alguma especialização e que os mesmos não compõem uma região, mas sim, grupos de municípios dispersos por todo o estado Mato-grossense.

  19. HISTORIA FUNCIONAL DE MORFOLOGÍAS LINGÜÍSTICAS Y SU EFECTO EN UN AJUSTE CONVENCIONAL/ FUNCTIONAL HISTORY OF LINGUISTIC MORPHOLOGIES AND THEIR EFFECT ON A CONVENTIONAL ADJUSTMENT/ HISTÓRIA FUNCIONAL DE MORFOLOGIAS LINGÜÍSTICAS E SEU EFEITO EM UM AJUSTE CONVENCIONAL

    Directory of Open Access Journals (Sweden)

    Nataly Yáñez Ramírez

    2011-12-01

    Full Text Available Se observó si diferentes historias funcionales construidas durante la adquisición de un conjunto de morfologías lingüísticas facilitaban un ajuste convencional. Participaron 24 estudiantes universitarios distribuidos en tres grupos, expuestos a entrenamientos construidos bajo la lógica de diferentes niveles de interacción: contextual, suplementario o selector (Ribes y López, 1985; y posteriormente se evaluó su ejecución en una tarea convencional. El entrenamiento cuyo criterio de ajuste era de tipo selector fue la que más facilitó tanto la adquisición de las morfologías lingüísticas como su uso en la tarea, efecto que pareció más evidente en los hablantes que en los escuchas. No se encontraron diferencias entre los entrenamientos contextual y suplementario. Los resultados se discuten en términos de sus implicaciones teóricas y metodológicas.

  20. Avaliação estrutural da escala de ajustamento diádico Evaluacíon de la escala de ajuste conyugal Structural assessment of the dyadic adjustment scale

    Directory of Open Access Journals (Sweden)

    José Augusto Evangelho Hernandez

    2008-09-01

    Full Text Available O objetivo deste estudo foi avaliar a Escala de Ajustamento Diádico respondida por uma amostra não-probabilística de homens e mulheres brasileiros que estavam em relacionamento amoroso de diversos tipos. Os 542 sujeitos foram recrutados em diversos locais de Porto Alegre/RS e região metropolitana. Através da técnica estatística Análise Fatorial, este estudo realizou um exame da estrutura da escala. Os resultados obtidos foram comparados com o estudo original de construção do instrumento e outras confirmações subseqüentes. Através da comparação dos escores médios dos diferentes tipos de casais da amostra atual se pôde verificar o poder discriminativo do instrumento e, além disso, foi examinada sua fidedignidade. Apareceram evidências que dão razoável suporte à versão brasileira do instrumento para sua utilização na pesquisa e na clínica psicológica.El propósito del estudio presente fue evaluar la Escala de Ajuste Conyugal contestada por una muestra non-probabilistic de hombres y mujeres brasileños que estuvieron implicados con relaciones de amor de varias clases. Los 542 sujetos fueron reclutados en varios sitios en Porto Alegre/RS y su área metropolitana. Con la técnica de estadística del análisis factorial, este estudio examinó la estructura de la escala. Los resultados fueron comparados a la construcción original del instrumento y de otras confirmaciones subsecuentes. Comparando las puntuaciones promedio de las clases diferentes de parejas de la muestra presente, podemos verificar el poder discriminatorio del instrumento, además de esto, su fiabilidad fue examinada también. Pruebas mostradas, del apoyo razonable a la versión brasileña del instrumento para su uso en la investigación y en clínica de psicología.The Dyadic Adjustment Scale answered by a non-probabilistic sample of Brazilian males and females involved in different types of love relationships is assessed. The 542 subjects were recruited in

  1. Elasto-plastic hardening models adjustment to ferritic, austenitic and austenoferritic Rebar; Ajuste de los aceros corrugados ferríticos, austeníticos y austenoferríticos a los modelos de endurecimiento elastoplástico por deformación

    Energy Technology Data Exchange (ETDEWEB)

    Hortigóna, B.; Gallardo, J.M.; Nieto-García, E.J.; López, J.A.

    2017-09-01

    de Rasmussen presentando un exponente de valor 6 realizando un ajuste libre de la función correspondiente. Para los aceros inoxidables Dúplex se obtienen muy bajos ajustes para los dos modelos citados.

  2. MRI-guided brachytherapy for cancer of the oesophagus

    International Nuclear Information System (INIS)

    Aydin, H.; Bachmann, G.; Lieven, H. von; Sens, M.

    1993-01-01

    A method of brachytherapy treatment planning using MRI is presented. In 13 patients with inoperable squamous cell cancer of the thoracic oesophagus an intraluminal afterloading boost with MRI assistance was performed. A new type of flexible catheter was filled with 1/100 diluted Gd-DTPA and introduced into the oesophagus before performing MRI in the sagittal, coronal and transverse planes. One sagittal or coronal picture which showed the catheter tip and the residual cancer was magnified to ''life size''. The position of the catheter was corrected if necessary and the treatment volume decided. The contrast medium was then aspirated out of the catheter and a thinner afterloading catheter pushed into the outer catheter. The patient was moved immediately to the afterloading room and received the first dose of boost irradiation. This method allows much more precise brachytherapy planning since it shows the cancer and the catheter together. It is superior to localising the cancer with a barium swallow or endoscopy because MRI visualises the whole extent of the residual cancer, which can then be covered with the necessary dose. (orig.)

  3. Should helical tomotherapy replace brachytherapy for cervical cancer? Case report.

    Science.gov (United States)

    Hsieh, Chen-Hsi; Wei, Ming-Chow; Hsu, Yao-Peng; Chong, Ngot-Swan; Chen, Yu-Jen; Hsiao, Sheng-Mou; Hsieh, Yen-Ping; Wang, Li-Ying; Shueng, Pei-Wei

    2010-11-23

    Stereotactic body radiation therapy (SBRT) administered via a helical tomotherapy (HT) system is an effective modality for treating lung cancer and metastatic liver tumors. Whether SBRT delivered via HT is a feasible alternative to brachytherapy in treatment of locally advanced cervical cancer in patients with unusual anatomic configurations of the uterus has never been studied. A 46-year-old woman presented with an 8-month history of abnormal vaginal bleeding. Biopsy revealed squamous cell carcinoma of the cervix. Magnetic resonance imaging (MRI) showed a cervical tumor with direct invasion of the right parametrium, bilateral hydronephrosis, and multiple uterine myomas. International Federation of Gynecology and Obstetrics (FIGO) stage IIIB cervical cancer was diagnosed. Concurrent chemoradiation therapy (CCRT) followed by SBRT delivered via HT was administered instead of brachytherapy because of the presence of multiple uterine myomas with bleeding tendency. Total abdominal hysterectomy was performed after 6 weeks of treatment because of the presence of multiple uterine myomas. Neither pelvic MRI nor results of histopathologic examination at X-month follow-up showed evidence of tumor recurrence. Only grade 1 nausea and vomiting during treatment were noted. Lower gastrointestinal bleeding was noted at 14-month follow-up. No fistula formation and no evidence of haematological, gastrointestinal or genitourinary toxicities were noted on the most recent follow-up. CCRT followed by SBRT appears to be an effective and safe modality for treatment of cervical cancer. Larger-scale studies are warranted.

  4. Should helical tomotherapy replace brachytherapy for cervical cancer? Case report

    Directory of Open Access Journals (Sweden)

    Chen Yu-Jen

    2010-11-01

    Full Text Available Abstract Background Stereotactic body radiation therapy (SBRT administered via a helical tomotherapy (HT system is an effective modality for treating lung cancer and metastatic liver tumors. Whether SBRT delivered via HT is a feasible alternative to brachytherapy in treatment of locally advanced cervical cancer in patients with unusual anatomic configurations of the uterus has never been studied. Case Presentation A 46-year-old woman presented with an 8-month history of abnormal vaginal bleeding. Biopsy revealed squamous cell carcinoma of the cervix. Magnetic resonance imaging (MRI showed a cervical tumor with direct invasion of the right parametrium, bilateral hydronephrosis, and multiple uterine myomas. International Federation of Gynecology and Obstetrics (FIGO stage IIIB cervical cancer was diagnosed. Concurrent chemoradiation therapy (CCRT followed by SBRT delivered via HT was administered instead of brachytherapy because of the presence of multiple uterine myomas with bleeding tendency. Total abdominal hysterectomy was performed after 6 weeks of treatment because of the presence of multiple uterine myomas. Neither pelvic MRI nor results of histopathologic examination at X-month follow-up showed evidence of tumor recurrence. Only grade 1 nausea and vomiting during treatment were noted. Lower gastrointestinal bleeding was noted at 14-month follow-up. No fistula formation and no evidence of haematological, gastrointestinal or genitourinary toxicities were noted on the most recent follow-up. Conclusions CCRT followed by SBRT appears to be an effective and safe modality for treatment of cervical cancer. Larger-scale studies are warranted.

  5. Iodine-125 orbital brachytherapy with a prosthetic implant in situ

    Energy Technology Data Exchange (ETDEWEB)

    Stannard, Clare [Groote Schuur Hospital and Cape Town Univ. (South Africa). Dept. of Radiation Oncology; Maree, Gert; Munro, Roger [Groote Schuur Hospital and Cape Town Univ. (South Africa). Dept. of Medical Physics; Lecuona, Karin [Groote Schuur Hospital and Cape Town Univ. (South Africa). Dept. of Ophthalmology; Sauerwein, Wolfgang [Universitaetsklinikum Essen (Germany). Strahlenklinik, NCTeam

    2011-05-15

    Purpose: Brachytherapy is one method of irradiating the orbit after enucleation of an eye with a malignant tumor that has a potential to recur. It consists of 6 trains of I-125 seeds placed around the periphery of the orbit, a shorter central train, and a metal disc, loaded with seeds, placed beneath the eyelids. The presence of a prosthetic orbital implant requires omission of the central train and adjustment of the activity of the seeds in the anterior orbit around the prosthesis. Patients and Methods: This is a retrospective review of the technical modifications and outcome of 12 patients treated in this manner: 6 with retinoblastoma, 5 with malignant melanoma, and 1 with an intraocular rhabdomyosarcoma. The median dose was 35.5 Gy in 73 hours for retinoblastoma and 56 Gy in 141 hours for malignant melanoma. Patients with retinoblastoma and rhabdomyosarcoma also received chemotherapy. Results: The tubes can be placed satisfactorily around the prosthesis. The increased activity in the anterior half of the tubes produced comparable dose distributions. There have been no orbital recurrences, no extrusion of the prosthesis, and cosmesis is good. Conclusion: Insertion of a prosthetic implant at the time of enucleation greatly enhances the subsequent cosmetic appearance. This should be encouraged unless there is frank tumor in the orbit. Orbital brachytherapy without the central train continues to give excellent local control. The short treatment time and good cosmesis are added advantages. The patient is spared the expense and inconvenience of removing and replacing the prosthetic implant. (orig.)

  6. Monte Carlo Simulations Validation Study: Vascular Brachytherapy Beta Sources

    International Nuclear Information System (INIS)

    Orion, I.; Koren, K.

    2004-01-01

    During the last decade many versions of angioplasty irradiation treatments have been proposed. The purpose of this unique brachytherapy is to administer a sufficient radiation dose into the vein walls in order to prevent restonosis, a clinical sequel to balloon angioplasty. The most suitable sources for this vascular brachytherapy are the β - emitters such as Re-188, P-32, and Sr-90/Y-90, with a maximum energy range of up to 2.1 MeV [1,2,3]. The radioactive catheters configurations offered for these treatments can be a simple wire [4], a fluid filled balloon or a coated stent. Each source is differently positioned inside the blood vessel, and the emitted electrons ranges therefore vary. Many types of sources and configurations were studied either experimentally or with the use of the Monte Carlo calculation technique, while most of the Monte Carlo simulations were carried out using EGS4 [5] or MCNP [6]. In this study we compared the beta-source absorbed-dose versus radial-distance of two treatment configurations using MCNP and EGS4 simulations. This comparison was aimed to discover the differences between the MCNP and the EGS4 simulation code systems in intermediate energies electron transport

  7. Brachytherapy dosimetry parameters calculated for a 131Cs source

    International Nuclear Information System (INIS)

    Rivard, Mark J.

    2007-01-01

    A comprehensive analysis of the IsoRay Medical model CS-1 Rev2 131 Cs brachytherapy source was performed. Dose distributions were simulated using Monte Carlo methods (MCNP5) in liquid water, Solid TM , and Virtual Water TM spherical phantoms. From these results, the in-water brachytherapy dosimetry parameters have been determined, and were compared with those of Murphy et al. [Med. Phys. 31, 1529-1538 (2004)] using measurements and simulations. Our results suggest that calculations obtained using erroneous cross-section libraries should be discarded as recommended by the 2004 AAPM TG-43U1 report. Our MC Λ value of 1.046±0.019 cGy h -1 U -1 is within 1.3% of that measured by Chen et al. [Med. Phys. 32, 3279-3285 (2005)] using TLDs and the calculated results of Wittman and Fisher [Med. Phys. 34, 49-54 (2007)] using MCNP5. Using the discretized energy approach of Rivard [Appl. Radiat. Isot. 55, 775-782 (2001)] to ascertain the impact of individual 131 Cs photons on radial dose function and anisotropy functions, there was virtual equivalence of results for 29.461≤E γ ≤34.419 keV and for a mono-energetic 30.384 keV photon source. Comparisons of radial dose function and 2D anisotropy function data are also included, and an analysis of material composition and cross-section libraries was performed

  8. Fricke gel-layer dosimetry in HDR brachytherapy

    International Nuclear Information System (INIS)

    Gambarini, G.; Negri, A.; Carrara, M.; Marchesini, R.

    2008-01-01

    Full text: In the last decade, technological improvements in radiotherapy have been significant and consequently the use and importance of radiotherapy in cancer treatment have increased greatly. In brachytherapy, new possibilities have been opened by the impressive progresses in 3D imaging, by the development of sophisticated techniques for modern afterloaders and by the constantly increasing speed and capacity of computers. However, these methodological improvements require corresponding improvements in the dosimetry methods, in order to ensure that the values calculated with computer treatment planning systems, adopted in the clinical praxis, agree with the delivered dose distributions. Fricke gel-layer dosimeters (FGLD) are under study by our group as a reliable alternative to films, semiconductors arrays or thermoluminescent dosimeters (TLDs). In the last years, we have significantly improved this technique by defining the FGLD best chemical composition, by optimizing the image acquisition assessment and by developing a dedicated software for image analysis. In this study, experimental measurements of planar dose distributions of a clinical 192 Ir source (Microselectron HDR, Nucletron) obtained by irradiating a series of piled-up FGL dosimeters in a tissue-equivalent phantom are presented. The obtained results were in accordance to TLD measurements and to treatment planning system (Plato, Nucletron) calculations. FGLD have proven to be a reliable tool to achieve HDR brachytherapy dose distribution measurements

  9. Factors affecting radiation injury after interstitial brachytherapy for brain tumors

    International Nuclear Information System (INIS)

    Leibel, S.A.; Gutin, P.H.; Davis, R.L.

    1991-01-01

    The effects of brachytherapy on normal brain tissue are not easily delineated in the clinical setting because of the presence of concurrent radiation-induced changes in the coexistent brain tumor. Sequential morphologic studies performed after the implantation of radioactive sources into the brains of experimental animals have provided a better understanding of the character and magnitude of the structural changes produced by interstitial irradiation on normal brain tissue. Furthermore, the clinical experience accumulated thus far provides not only relevant information, but also some guidelines for future treatment policies. In this paper, the authors summarize the experimental findings and review the pathologic and clinical features of brain injury caused by interstitial brachytherapy. A number of studies in the older literature examined the effects of radioisotopes such as radium-226 (38--43), radon-22 (44--46), gold-198 (29,47--50), tantalum-182 (29,51,52) yttrium-9- (50,53,54), and cobalt-60 (29,50,55). This review is restricted to low- and high-activity encapsulated iodine-125 ( 125 I) and iridium-192 ( 192 Ir), the isotopes that are most commonly used in current clinical practice

  10. Should helical tomotherapy replace brachytherapy for cervical cancer? Case report

    International Nuclear Information System (INIS)

    Hsieh, Chen-Hsi; Wei, Ming-Chow; Hsu, Yao-Peng; Chong, Ngot-Swan; Chen, Yu-Jen; Hsiao, Sheng-Mou; Hsieh, Yen-Ping; Wang, Li-Ying; Shueng, Pei-Wei

    2010-01-01

    Stereotactic body radiation therapy (SBRT) administered via a helical tomotherapy (HT) system is an effective modality for treating lung cancer and metastatic liver tumors. Whether SBRT delivered via HT is a feasible alternative to brachytherapy in treatment of locally advanced cervical cancer in patients with unusual anatomic configurations of the uterus has never been studied. A 46-year-old woman presented with an 8-month history of abnormal vaginal bleeding. Biopsy revealed squamous cell carcinoma of the cervix. Magnetic resonance imaging (MRI) showed a cervical tumor with direct invasion of the right parametrium, bilateral hydronephrosis, and multiple uterine myomas. International Federation of Gynecology and Obstetrics (FIGO) stage IIIB cervical cancer was diagnosed. Concurrent chemoradiation therapy (CCRT) followed by SBRT delivered via HT was administered instead of brachytherapy because of the presence of multiple uterine myomas with bleeding tendency. Total abdominal hysterectomy was performed after 6 weeks of treatment because of the presence of multiple uterine myomas. Neither pelvic MRI nor results of histopathologic examination at X-month follow-up showed evidence of tumor recurrence. Only grade 1 nausea and vomiting during treatment were noted. Lower gastrointestinal bleeding was noted at 14-month follow-up. No fistula formation and no evidence of haematological, gastrointestinal or genitourinary toxicities were noted on the most recent follow-up. CCRT followed by SBRT appears to be an effective and safe modality for treatment of cervical cancer. Larger-scale studies are warranted

  11. Inverse treatment planning based on MRI for HDR prostate brachytherapy

    International Nuclear Information System (INIS)

    Citrin, Deborah; Ning, Holly; Guion, Peter; Li Guang; Susil, Robert C.; Miller, Robert W.; Lessard, Etienne; Pouliot, Jean; Xie Huchen; Capala, Jacek; Coleman, C. Norman; Camphausen, Kevin; Menard, Cynthia

    2005-01-01

    Purpose: To develop and optimize a technique for inverse treatment planning based solely on magnetic resonance imaging (MRI) during high-dose-rate brachytherapy for prostate cancer. Methods and materials: Phantom studies were performed to verify the spatial integrity of treatment planning based on MRI. Data were evaluated from 10 patients with clinically localized prostate cancer who had undergone two high-dose-rate prostate brachytherapy boosts under MRI guidance before and after pelvic radiotherapy. Treatment planning MRI scans were systematically evaluated to derive a class solution for inverse planning constraints that would reproducibly result in acceptable target and normal tissue dosimetry. Results: We verified the spatial integrity of MRI for treatment planning. MRI anatomic evaluation revealed no significant displacement of the prostate in the left lateral decubitus position, a mean distance of 14.47 mm from the prostatic apex to the penile bulb, and clear demarcation of the neurovascular bundles on postcontrast imaging. Derivation of a class solution for inverse planning constraints resulted in a mean target volume receiving 100% of the prescribed dose of 95.69%, while maintaining a rectal volume receiving 75% of the prescribed dose of <5% (mean 1.36%) and urethral volume receiving 125% of the prescribed dose of <2% (mean 0.54%). Conclusion: Systematic evaluation of image spatial integrity, delineation uncertainty, and inverse planning constraints in our procedure reduced uncertainty in planning and treatment

  12. Methodology of quality control for brachytherapy {sup 125}I seeds

    Energy Technology Data Exchange (ETDEWEB)

    Moura, Eduardo S.; Zeituni, Carlos A.; Manzoli, Jose E.; Rostelato, Maria Elisa C.M. [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)]. E-mail: esmoura@ipen.br

    2007-07-01

    This paper presents the methodology of quality control of {sup 125}I seeds used for brachytherapy. The {sup 125}I seeds are millimeter titanium capsules widely used in permanent implants of prostate cancer, allowing a high dose within the tumour and a low dose on the surrounding tissues, with very low harm to the other tissues. Besides, with this procedure, the patients have a low impotence rate and a small incidence of urinary incontinence. To meet the medical standards, an efficient quality control is necessary, showing values with the minimum uncertainness possible, concerning the seeds dimensions and their respective activities. The medical needles are used to insert the seeds inside the prostate. The needles used in brachytherapy have an internal diameter of 1.0 mm, so it is necessary {sup 125}I seeds with an external maximum diameter of 0.85 mm. For the seeds and the spacer positioning on the planning sheet, the seeds must have a length between 4.5 and 5.0 mm. The activities must not vary more than 5% in each batch of {sup 125}I seeds. For this methodology, we used two ionization chamber detectors and one caliper. In this paper, the methodology using one control batch with 75 seeds manufactured by GE Health care Ltd is presented. (author)

  13. Observations on rotating needle insertions using a brachytherapy robot

    International Nuclear Information System (INIS)

    Meltsner, M A; Ferrier, N J; Thomadsen, B R

    2007-01-01

    A robot designed for prostate brachytherapy implantations has the potential to greatly improve treatment success. Much of the research in robotic surgery focuses on measuring accuracy. However, there exist many factors that must be optimized before an analysis of needle placement accuracy can be determined. Some of these parameters include choice of the needle type, insertion velocity, usefulness of the rotating needle and rotation speed. These parameters may affect the force at which the needle interacts with the tissue. A reduction in force has been shown to decrease the compression of the prostate and potentially increase the accuracy of seed position. Rotating the needle as it is inserted may reduce frictional forces while increasing accuracy. However, needle rotations are considered to increase tissue damage due to the drilling nature of the insertion. We explore many of the factors involved in optimizing a brachytherapy robot, and the potential effects each parameter may have on the procedure. We also investigate the interaction of rotating needles in gel and suggest the rotate-cannula-only method of conical needle insertion to minimize any tissue damage while still maintaining the benefits of reduced force and increased accuracy

  14. High dose rate brachytherapy in treatment of high grade astrocytomas

    International Nuclear Information System (INIS)

    Garcia-Alejo, R.; Delgado, J.M.; Cerro, E. del; Torres, J.J.; Martinez, R.

    1996-01-01

    From May 1994 to June 1995, 18 patients with high grade astrocytomas were entered prospectively on a selective protocol combining surgery, external beam radiotherapy, stereotactic interstitial implantation with HDR Iridium 192 and chemotherapy. Only those patients with tumor size 100cc or less average dimension, high grade astrocytoma, Karnofsky 70 or greater, unilateral, circumscribed, unifocal, tumor stable or responding to external radiation and supratentorial were included in the study. Ages ranged from 16 to 69 years. There were 13 males and 5 females. Surgery consisted of biopsy only in 3 patients, subtotal resection in 11, and gross total resection in 4 patients. Focal external beam radiation portals included the contrast enhancing mass on CT scan plus a 3 cm margin. The protocol called for minimum tumor dose of 60 Gy to be given in 2 Gy daily fractions. An interstitial brachytherapy boost was to be performed two weeks after the conclusion of external beam radiation. The dose was 30 Gy in 4 fractions. The authors analyze on basis on their personal experience, the possibilities and the limits offered by this therapeutic procedure in neuro-oncology. Using stereotactic techniques, interstitial brachytherapy of brain tumors was technically possible with negligible acute morbidity and mortality, and appeared to be effective and may provide for an increase in tumor control in selected cases

  15. Prostate HDR brachytherapy catheter displacement between planning and treatment delivery

    International Nuclear Information System (INIS)

    Whitaker, May; Hruby, George; Lovett, Aimee; Patanjali, Nitya

    2011-01-01

    Background and purpose: HDR brachytherapy is used as a conformal boost for treating prostate cancer. Given the large doses delivered, it is critical that the volume treated matches that planned. Our outpatient protocol comprises two 9 Gy fractions, two weeks apart. We prospectively assessed catheter displacement between CT planning and treatment delivery. Materials and methods: Three fiducial markers and the catheters were implanted under transrectal ultrasound guidance. Metal marker wires were inserted into 4 reference catheters before CT; marker positions relative to each other and to the marker wires were measured from the CT scout. Measurements were repeated immediately prior to treatment delivery using pelvic X-ray with marker wires in the same reference catheters. Measurements from CT scout and film were compared. For displacements of 5 mm or more, indexer positions were adjusted prior to treatment delivery. Results: Results are based on 48 implants, in 25 patients. Median time from planning CT to treatment delivery was 254 min (range 81–367 min). Median catheter displacement was 7.5 mm (range −2.9–23.9 mm), 67% of implants had displacement of 5 mm or greater. Displacements were predominantly caudal. Conclusions: Catheter displacement can occur in the 1–3 h between the planning CT scan and treatment. It is recommended that departments performing HDR prostate brachytherapy verify catheter positions immediately prior to treatment delivery.

  16. Intravascular ultrasound based dose assessment in endovascular brachytherapy

    International Nuclear Information System (INIS)

    Catalano, Gianpiero; Tamburini, Vittorio; Colombo, Antonio; Nishida, Takahiro; Parisi, Giovanni; Mazzetta, Chiara; Orecchia, Roberto

    2003-01-01

    Background: the role of endovascular brachytherapy in restenosis prevention is well documented. Dose is usually prescribed at a fixed distance from the source axis by angiographic quantification of vessel diameter. Recently, intravascular ultrasound (IVUS) was introduced in dose prescription, allowing a better evaluation of the vessel anatomy. This study retrospectively explores the difference between prescription following angiographic vessel sizing and delivered dose calculated with IVUS. Methods and results: Seventeen lesions were studied with IVUS, identifying on irradiated segment, three sections on which measuring minimal and maximal distance from the centre of IVUS catheter to the adventitia; using dedicated software, corresponding doses were calculated. The dose ranged widely, with maximal and minimal values of 71.6 and 4.9 Gy; furthermore, heterogeneity in dose among different sections was observed. In the central section, the maximal dose was 206% of the one prescribed with the QCA model at 2 mm from the source axis, while the minimal dose was 96%. In proximal and distal sections, respective values were 182, 45, 243, and 122%. Conclusions: Our analysis confirmed the dose inhomogeneity delivered with an angiographic fixed-dose prescription strategy. A dose variation was found along the irradiated segment due to the differences in vessel thickness. IVUS emerged as an important tool in endovascular brachytherapy, especially for irregular-shaped vessels

  17. Endoluminal high dose rate brachytherapy in the treatment of primary and recurrent bronchogenic tree malignancies

    Directory of Open Access Journals (Sweden)

    Maria Fortunato

    2009-03-01

    Full Text Available Introduction: Locally advanced tumours as the initial form of presentation of tumours in the bronchial tree are not a rare event. Bronchogenic recurrence is frequent in the natural history of some tumours. The choice of therapeutic options from the raft available depends on such variables as initial therapy, place of recurrence, symptoms and patient's physical status. Aim: To demonstrate the advantages of endoluminal brachytherapy (EBT with high dose rate (HDR in primary and recurrent tumour of the bronchial tree. Material and methods: A retrospective study of seven patients (pts with primary tumours of the colon, trachea and lung. Tracheobronchial recurrence (trachea, two pts, bronchus, five pts occurred betweenMarch 2003 and September 2004. Patients under-went EBT with HDR for primary or recurrent therapy in association with external radiotherapy, laser therapy and chemotherapy with palliative or curative intention. EBT with HDR doses of 5 to 7 Gy in 2 to 4 fractions at 1 cm from the source axis were given. Treatment included endoluminal application of Ir192 with a French 6 catheter. Results: There was symptomatic relief related to reduction of tumour in six of the seven patients treated. In one of the six patients studied, there was progression of the local disease between the second and third fractions of the treatment (obstruction of the trachea. In a mean follow up of 17 (2-40 months between EBT and this study, three patients are alive, one has no evidence of disease while two have had bronchial recurrence, four patients have died, one after massive haemoptysis and three due to disease progression. Discussion and conclusions: Patients undergoing brachytherapy for symptomatic primary tumours or endobronchial recurrence show good tolerance, important symptom relief and improved quality of life. Despite the small size of our sample, it is clear that EBT with HDR plays an important role in the palliative/curative treatment of these patients

  18. Linear study and bundle adjustment data fusion; Application to vision localization; Recherche lineaire et fusion de donnees par ajustement de faisceaux; Application a la localisation par vision

    Energy Technology Data Exchange (ETDEWEB)

    Michot, J.

    2010-12-09

    integrate this additional information directly into an extended bundle adjustment, by adding a constraint term in the weighted cost function. We evaluate three methods (based on machine learning or regularization) that dynamically select the weight associated to the constraint and show that these methods can be used in a real time multi-sensor SLAM, and validate them with different types of constraint on the orientation or on the scale. Experiments conducted on real video sequences show that this technique of constrained bundle adjustment reduces the drifts observed with the classical vision algorithms and improves the global accuracy of the positioning system. (author) [French] Les travaux presentes dans ce manuscrit concernent le domaine de la localisation et la reconstruction 3D par vision artificielle. Dans ce contexte, la trajectoire d'une camera et la structure 3D de la scene filmee sont initialement estimees par des algorithmes lineaires puis optimisees par un algorithme non-lineaire, l'ajustement de faisceaux. Cette these presente tout d'abord une technique de recherche de l'amplitude de deplacement (recherche lineaire), ou line search pour les algorithmes de minimisation iterative. La technique proposee est non iterative et peut etre rapidement implantee dans un ajustement de faisceaux traditionnel. Cette technique appelee recherche lineaire algebrique globale (G-ALS), ainsi que sa variante a deux dimensions (Two way-ALS), accelerent la convergence de l'algorithme d'ajustement de faisceaux. L'approximation de l'erreur de reprojection par une distance algebrique rend possible le calcul analytique d'une amplitude de deplacement efficace (ou de deux pour la variante Two way-ALS), par la resolution d'un polynome de degre 3 (G-ALS) ou 5 (Two way-ALS). Nos experimentations sur des donnees simulees et reelles montrent que cette amplitude, optimale en distance algebrique, est performante en distance euclidienne, et permet

  19. Results of brachytherapy boost in high risk breast cancer patients

    International Nuclear Information System (INIS)

    Battermann, J.J.

    1996-01-01

    Introduction: in breast conserving therapy the role of brachytherapy as a boost after whole breast irradiation is not clear. The series from the Netherlands Cancer Institute show a very high local control rate, but the question could be raised whether all these patients need a brachy boost. Therefore, it was decided at our institute, to deliver a brachy boost only to high risk patients, viz. patients with incomplete resection margins and/or extensive in situ cancer (ECI). Materials and methods: in the period 1988 through 1993 a total of 148 patients with 151 breast tumours received a boost on the tumour bed using brachytherapy. Age varied from 25 till 74 years, with a mean age of 52.3 years. Incomplete resection margins were found in 60 patients, ECI in 31 and both in 49 patients. In the majority of patients, the ECI component was not completely removed. T-stage was unknown in 9 patients. T1 in 83, T2 in 49 and T3 in 10. Nodal status was N0 in 119 and N1 in 33 patients. Infiltrating duct carcinoma was the most common histology. No infiltrating growth was found in 6 patients, but one patient presented a positive node. The interval period between day of operation and day of brachytherapy implantation was between 3 and 4 months in 62%. The mean interval between completion of beam irradiation and day of implantation was 18 days, while 12 patients received their brachytherapy previous to the beam irradiation. External irradiation was with two tangential fields and a total dose of 50 Gy in 25 fractions over 6 weeks (9 fractions in two weeks). The number of needles in two planes. Most patients were implanted under local anaesthesia. Dose rate in 97 patients was 51 - 60 cGy/h. Results: follow-up for patients alive varied from 2 years till 7 years with a mean follow-up period of 4 years. One hundred and twenty five patients are alive, including 6 patients with manifest metastases. Local recurrence was encountered in 8 patients (interval 14 - 60 months, mean 30 months), with

  20. Treatment of localized prostate cancer with brachytherapy: six years experience

    International Nuclear Information System (INIS)

    Martinez, Pablo; Dourado, Leandro; Giudice, Carlos; Villamil, Wenceslao; Palacios, Victor; Sardi, Mabel; Damia, Oscar

    2006-01-01

    The usage of ultrasound scan to perform prostate biopsy punctures, the new radiation therapies and the more accurate selection of patients has allowed brachytherapy to play an important role in the treatment of the localized pathology. The objective of this paper is to review the results obtained when treating the localized prostate cancer by using brachytherapy with mud 125. Materials and methods: Between December 1999 and July 2006, 100 prostate cancer patients were treated at the Hospital Italiano de Buenos Aires, using brachytherapy with mud 125. One of the patients was treated with a combined therapy (brachytherapy + external radiotherapy). For that reason, the patient was not taken into consideration for this paper. The average age was 65.95 (52-79). The tumoral stages were T1c in 81% of the patients and T2a in 19% of them. The PSA was always below 15 ng/ml, with an average of 8.92 ng/ml; inferior to 10 ng/ml in 72 patients and between 10 and 15 ng/m ml in 28 of them. The average prostate volume was 34.68 c.c. (18.70 c.c.-58.00 c.c.). The combined Gleason score was below 6 (except for three patients with Gleason 7 who had a PSA below 10, stage T1c). The dose used was 16,000 cGy as recommended by the TG43. The energy charge of each seed was between 0.28 and 0.40 mci. Thirty days later, a prostate axial computer tomography was carried out every 3 mm. with a scanning set every 5 mm. to perform a dosimetric control of the implant. Results: The average age was 65.95 (52-79). The control computer tomography showed an adequate dosimetric coverage for the entire prostate volume, with a maximum urethral dose not above 400 Gy and a maximum rectal dose below 100 Gy. The PSA of all patients decreased to a normal level 6 months after the treatment started. The average follow-up of the 71 patients able to be tested from an oncological perspective lasted 31.15 months, with a minimum of 18 and a maximum of 72 months. Currently, seven patients of those tested (9.86%) manifest

  1. Results in patients treated with high-dose-rate interstitial brachytherapy for oral tongue cancer

    International Nuclear Information System (INIS)

    Yamamoto, Michinori; Shirane, Makoto; Ueda, Tsutomu; Miyahara, Nobuyuki

    2006-01-01

    Eight patients were treated with high-dose-rate interstitial brachytherapy for oral tongue cancer between September 2000 and August 2004. The patient distribution was 1 T1, 5 T2, 1 T3, and 1 T4a. Patients received 50-60 Gy in 10 fractions over seven days with high-dose-rate brachytherapy. Six of the eight patients were treated with a combination of external beam radiotherapy (20-30 Gy) and interstitial brachytherapy. The two-year primary local control rate was 83% for initial case. High-dose-rate brachytherapy was performed safely even for an aged person, and was a useful treatment modality for oral tongue cancer. (author)

  2. Pulsed dose rate (PDR) brachytherapy as salvage treatment of locally advanced or recurrent gynecologic cancer

    DEFF Research Database (Denmark)

    Jensen, P T; Roed, H; Engelholm, S A

    1998-01-01

    PURPOSE: Pulsed dose rate (PDR) brachytherapy is a new treatment option permitting dose distribution optimization in interstitial implants. It possesses the advantage of equipment simplification and radiation protection to the staff, compared to the manually afterloading technique. This study pre...

  3. Postal auditing methodology used to find out the performance of high rate brachytherapy equipment

    International Nuclear Information System (INIS)

    Morales, J.A.; Campa, R.

    1998-01-01

    This work describes results from a methodology implemented at the Secondary Laboratory for Dosimetric Calibration at CPHR used to check the brachytherapy performance at high doses rate using Cesium 137 or cobalt 60 sources

  4. Ajuste do modelo de Schumacher e Hall e aplicação de redes neurais artificiais para estimar volume de árvores de eucalipto Adjustment of the Schumacher and Hall model and application of artificial neural networks to estimate volume of eucalypt trees

    Directory of Open Access Journals (Sweden)

    Mayra Luiza Marques da Silva

    2009-12-01

    Full Text Available Objetivou-se, neste trabalho, avaliar o ajuste do modelo volumétrico de Schumacher e Hall por diferentes algoritmos, bem como a aplicação de redes neurais artificiais para estimação do volume de madeira de eucalipto em função do diâmetro a 1,30 m do solo (DAP, da altura total (Ht e do clone. Foram utilizadas 21 cubagens de povoamentos de clones de eucalipto com DAP variando de 4,5 a 28,3 cm e altura total de 6,6 a 33,8 m, num total de 862 árvores. O modelo volumétrico de Schumacher e Hall foi ajustado nas formas linear e não linear, com os seguintes algoritmos: Gauss-Newton, Quasi-Newton, Levenberg-Marquardt, Simplex, Hooke-Jeeves Pattern, Rosenbrock Pattern, Simplex, Hooke-Jeeves e Rosenbrock, utilizado simultaneamente com o método Quasi-Newton e com o princípio da Máxima Verossimilhança. Diferentes arquiteturas e modelos (Multilayer Perceptron MLP e Radial Basis Function RBF de redes neurais artificiais foram testados, sendo selecionadas as redes que melhor representaram os dados. As estimativas dos volumes foram avaliadas por gráficos de volume estimado em função do volume observado e pelo teste estatístico L&O. Assim, conclui-se que o ajuste do modelo de Schumacher e Hall pode ser usado na sua forma linear, com boa representatividade e sem apresentar tendenciosidade; os algoritmos Gauss-Newton, Quasi-Newton e Levenberg-Marquardt mostraram-se eficientes para o ajuste do modelo volumétrico de Schumacher e Hall, e as redes neurais artificiais apresentaram boa adequação ao problema, sendo elas altamente recomendadas para realizar prognose da produção de florestas plantadas.This research aimed at evaluating the adjustment of Schumacher and Hall volumetric model by different algorithms and the application of artificial neural networks to estimate the volume of wood of eucalyptus according to the diameter at breast height (DBH, total height (Ht of the clone. For such, 21 scalings of stands of eucalyptus clones were used with

  5. Effect of brachytherapy technique and patient characteristics on cervical cancer implant dosimetry

    Energy Technology Data Exchange (ETDEWEB)

    Anker, Christopher J., E-mail: chris.anker@hci.utah.edu [Department of Radiation Oncology, Huntsman Cancer Hospital, University of Utah, Salt Lake City, UT (United States); O' Donnell, Kristen [Department of Radiation Oncology, The University of Arizona, Tucson, AZ (United States); Boucher, Kenneth M. [Department of Oncological Sciences, Huntsman Cancer Institute, University of Utah, Salt Lake City, UT (United States); Gaffney, David K. [Department of Radiation Oncology, Huntsman Cancer Hospital, University of Utah, Salt Lake City, UT (United States)

    2013-01-01

    Our purpose was to evaluate the relationship between brachytherapy technique and patient characteristics on dose to organs-at-risk (OARs) in patients undergoing high dose rate (HDR) brachytherapy for cervical cancer. From 1998 to 2008, 31 patients with cervical cancer with full dosimetric data were identified who received definitive external-beam radiation and HDR brachytherapy with tandem and ovoid applicators. Doses were recorded at point A, the International Commission on Radiation Units and Measurements (ICRU)-38 rectal point, the ICRU-38 bladder point, the vaginal surface, and the pelvic sidewall. Generalized estimating equations were used to determine the significance of changes in OAR to point A dose ratios with differences in brachytherapy technique or patient characteristics. Patients underwent a median of 5 brachytherapy procedures (range, 3 to 5), with a total of 179 procedures for 31 patients. For all brachytherapy treatments, the average ratios between the doses for the rectal, bladder, vaginal surface, and pelvic sidewall reference points to those at point A were 0.49, 0.59, 1.15, and 0.17, respectively. In general, decreased OAR dose was associated with a lower stage, younger age, increased ovoid size, increased tandem length, and earlier implant number. Increased tandem curvature significantly increased bladder dose and decreased rectal dose. Intravenous anesthesia usage was not correlated with improved dosimetry. This study allowed identification of patient and procedure characteristics influencing OAR dosing. Although the advent of 3-dimensional (3D) image-guided brachytherapy will bring new advances in treatment optimization, the actual technique involved at the time of the brachytherapy implant procedure will remain important.

  6. A study on applying Ra needle interstitial brachytherapy for oral cancer

    International Nuclear Information System (INIS)

    Yoshida, Shunichi; Komiya, Yoshiaki; Uchida, Ikuhiro; Tashiro, Kazuyoshi

    1999-01-01

    To investigate applicability of Ra needle interstitial brachytherapy, 93 cases of oral squamous carcinoma were examined. The patients underwent Ra needle interstitial brachytherapy as thorough therapy in our hospital. The criteria of applying Ra needle interstitial brachytherapy was diameter of within 5 cm and depth within 2 cm of tumor size. Ra needle interstitial brachytherapy was applied to 82 cases of tongue, 10 cases of oral floor and one case of lower lip carcinomas. The local control rate was 92.5%, and secondary neck metastasis was 32.3% in all cases applied Ra needle interstitial brachytherapy. The results were not bad compared with surgical treatment. However, the 5-year cumulative survival rate was 64.9%, which was not good enough at the result to obtain a good local control rate and secondary neck metastasis rate. The result was relative to low treatment result of local recurrence cases with Ra needle interstitial brachytherapy. To improve the result, it is important to distinguish local recurrence from radioinduced ulcer, and to start early secondary treatment. The cases in which cervical lymph node metastasis was found as the first examination underwent neck dessection after Ra needle interstitial brachytherapy. The 5-year cumulative survival rate was 83.3% in N1 cases and 40.6% in N2 cases, and the result of N2 cases was poorer than N1 cases with a significant difference. The results indicate that a needle having a diameter of within 5 cm, depth of within 2 cm and less than N1 can be applied during Ra needle interstitial brachytherapy for complete cure of cancer. (author)

  7. Temporal relationship between prostate brachytherapy and the diagnosis of colorectal cancer

    International Nuclear Information System (INIS)

    Gutman, Sarah A.; Merrick, Gregory S.; Butler, Wayne M.; Wallner, Kent E.; Allen, Zachariah A.; Galbreath, Robert W.; Adamovich, Edward

    2006-01-01

    Purpose: To identify the location of pretreatment and posttreatment colorectal malignancies and posttreatment colorectal polyps in patients with clinically localized prostate cancer managed with brachytherapy. Methods and Materials: From April 1995 through July 2004, 1,351 consecutive patients underwent brachytherapy for clinical stage T1b-T3a (American Joint Committee on Cancer, 2002) prostate cancer. Supplemental external beam radiotherapy (XRT) was administered to 699 patients. The median follow-up was 4.6 years. Operative and pathology reports were reviewed for all patients with pretreatment and posttreatment colorectal cancer and posttreatment colorectal polyps. Multiple parameters were evaluated for the development of colorectal cancer or colorectal polyps. Results: Colorectal cancer was diagnosed in 23 and 25 patients before and after prostate brachytherapy, respectively. No differences were identified in the distribution of colorectal cancers either before or after treatment (3 and 4 rectal cancers in the pre- and postbrachytherapy cohorts). Thirty-five of the 48 colorectal cancers (73%) were diagnosed within 5 years of brachytherapy with a peak incidence 1 year after brachytherapy. One hundred ninety-two colorectal polyps were diagnosed after brachytherapy, 160 (83%) occurred within 4 years of brachytherapy, and only 27 (14%) were located in the rectum. In multivariate Cox regression analysis, prostate D 9 (minimum percentage of the dose covering 90% of the target volume) predicted for posttreatment colorectal cancer. Rectal polyps were most closely related to patient age and percent positive biopsies, whereas sigmoid/colon polyps were best predicted by patient age, planning volume, and supplemental XRT. Conclusions: Colorectal cancer was diagnosed with equal frequency before and after brachytherapy with comparable geographic distributions. In addition, the vast majority of postbrachytherapy colorectal polyps were located beyond the confines of the rectum

  8. Utilization of prostate brachytherapy for low risk prostate cancer: Is the decline overstated?

    Science.gov (United States)

    Safdieh, Joseph; Wong, Andrew; Weiner, Joseph P; Schwartz, David; Schreiber, David

    2016-08-01

    Several prior studies have suggested that brachytherapy utilization has markedly decreased, coinciding with the recent increased utilization of intensity modulated radiation therapy, as well as an increase in urologist-owned centers. We sought to investigate the brachytherapy utilization in a large, hospital-based registry. Men with prostate cancer diagnosed between 2004-2012 and treated with either external beam radiation and/or prostate brachytherapy were abstracted from the National Cancer Database. In order to be included, men had to be clinically staged as T1c-T2aNx-0Mx-0, Gleason 6, PSA ≤ 10.0 ng/ml. Descriptive statistics were used to analyze brachytherapy utilization over time and were compared via χ(2). Multivariate logistic regression was used to assess for covariables associated with increased brachytherapy usage. There were 89,413 men included in this study, of which 37,054 (41.6%) received only external beam radiation, and 52,089 (58.4%) received prostate brachytherapy. The use of brachytherapy declined over time from 62.9% in 2004 to 51.3% in 2012 (p facilities (60.8% in 2004 to 47.0% in 2012, p facilities (63.7% in 2004 to 53.0% in 2012, p facilities than those who lived further. The use of intensity modulated radiation therapy increased during this same time period from 18.4% in 2004 to 38.2% in 2012 (p usage. In this hospital-based registry, prostate brachytherapy usage has declined for low risk prostate cancer as intensity modulated radiation therapy usage has increased. However, it still remains the treatment of choice for 51.3% of patients as of 2012.

  9. Quality control of 192Ir high dose rate after loading brachytherapy dose veracity

    International Nuclear Information System (INIS)

    Feng Zhongsu; Xu Xiao; Liu Fen

    2008-01-01

    Recently, 192 Ir high dose rate (HDR) afterloading are widely used in brachytherapy. The advantage of using HDR systems over low dose rate systems are shorter treatment time and higher fraction dose. To guarantee the veracity of the delivery dose, several quality control methods are deseribed in this work. With these we can improve the position precision, time precision and dose precision of the brachytherapy. (authors)

  10. Comparison between Japanese and French interstitial brachytherapy for head and neck cancer

    International Nuclear Information System (INIS)

    Nose, Takayuki; Koizumi, Masahiko; Nishiyama, Kinji; Inoue, Toshihiko

    2001-01-01

    Interstitial brachytherapy is the optimal radiotherapy modality for head and neck cancer because the highest dose conformity can be achieved, and implanted tubes can move synchronously with the tumor movement. Compared with radical surgery, interstitial brachytherapy can achieve equivalent local control with less morbidity and less functional deficit. In Japan, because of technical limitations, interstitial brachytherapy has been confined to treatment of small tongue cancers. To improve our head and neck cancer treatment, technical limitations should be eliminated and a wider indication for interstitial brachytherapy should be achieved. In France, interstitial brachytherapy has been technically more developed and widely indicated than in Japan. We analyzed the differences between Japanese (Osaka) and French (Lyon and Nancy) techniques, to improve our interstitial brachytherapy. Implant devices and techniques: French applicators (Longcip 1) are more flexible and more suitable for loop techniques of the soft palate, the base of the tongue, and the vallecula, than applicators available in Japan. Various implant techniques are established especially for the oropharynx in France. Mandibular protection: Lead blocks used in France can more effectively shield the mandible than our silicone spacers. We showed the dosimetric results in an experimental treatment setting. Dose specification: The five-mm dose specification method used in Japan can work only for easy cases, such as small oral tongue cancers and mouth floor cancers. For complicated implants, such as for the oropharynx, the CTV-based dose specification method used in France is essential for sufficient irradiation. Indications: The indication for head and neck interstitial brachytherapy in Japan is limited mostly to small oral tongue cancers. The indication in France is wider, including the oral cavity, the oropharynx, and postoperative cases. We can refine our head and neck cancer treatment if we combine French

  11. 6th Annual Conference of Indian Brachytherapy Society 2016 (IBSCON 2016) Proceedings

    OpenAIRE

    Srinivasan, Venkatesan; Kuppusamy, Thayalan; Bhalavat, Rajendra L.; Mahantshetty, Umesh; Yathiraj, Prahlad H.; Kumar, Uday P.; Sharan, Krishna; Singh, Anshul; Reddy, Anusha; Fernandes, Donald; Vidyasagar, M.S.; Kumar, Rishabh; Kala, Prachi; Narayanan, Geeta S.; Mandal, Sanjeet

    2016-01-01

    Purpose To report the incidence, severity, and time of onset of late toxicities in patients of endometrial adenocarcinoma (EA) treated with external beam radiotherapy (EBRT) + brachytherapy (BT), or vaginal brachytherapy (VBT) alone. Material and methods Archives of a single institution from 2008-2015 were studied. The indications for EBRT and VBT were based on standard recommendations. EBRT was planned to 50 Gy/25 fractions/5 weeks/3DCRT with 4-field ?box? technique on a dual energy linear a...

  12. High Dose-Rate Versus Low Dose-Rate Brachytherapy for Lip Cancer

    International Nuclear Information System (INIS)

    Ghadjar, Pirus; Bojaxhiu, Beat; Simcock, Mathew; Terribilini, Dario; Isaak, Bernhard; Gut, Philipp; Wolfensberger, Patrick; Brömme, Jens O.; Geretschläger, Andreas; Behrensmeier, Frank; Pica, Alessia; Aebersold, Daniel M.

    2012-01-01

    Purpose: To analyze the outcome after low-dose-rate (LDR) or high-dose-rate (HDR) brachytherapy for lip cancer. Methods and Materials: One hundred and three patients with newly diagnosed squamous cell carcinoma of the lip were treated between March 1985 and June 2009 either by HDR (n = 33) or LDR brachytherapy (n = 70). Sixty-eight patients received brachytherapy alone, and 35 received tumor excision followed by brachytherapy because of positive resection margins. Acute and late toxicity was assessed according to the Common Terminology Criteria for Adverse Events 3.0. Results: Median follow-up was 3.1 years (range, 0.3–23 years). Clinical and pathological variables did not differ significantly between groups. At 5 years, local recurrence-free survival, regional recurrence-free survival, and overall survival rates were 93%, 90%, and 77%. There was no significant difference for these endpoints when HDR was compared with LDR brachytherapy. Forty-two of 103 patients (41%) experienced acute Grade 2 and 57 of 103 patients (55%) experienced acute Grade 3 toxicity. Late Grade 1 toxicity was experienced by 34 of 103 patients (33%), and 5 of 103 patients (5%) experienced late Grade 2 toxicity; no Grade 3 late toxicity was observed. Acute and late toxicity rates were not significantly different between HDR and LDR brachytherapy. Conclusions: As treatment for lip cancer, HDR and LDR brachytherapy have comparable locoregional control and acute and late toxicity rates. HDR brachytherapy for lip cancer seems to be an effective treatment with acceptable toxicity.

  13. High Dose-Rate Versus Low Dose-Rate Brachytherapy for Lip Cancer

    Energy Technology Data Exchange (ETDEWEB)

    Ghadjar, Pirus, E-mail: pirus.ghadjar@insel.ch [Department of Radiation Oncology, Inselspital, Bern University Hospital, and University of Bern (Switzerland); Bojaxhiu, Beat [Department of Radiation Oncology, Inselspital, Bern University Hospital, and University of Bern (Switzerland); Simcock, Mathew [Swiss Group for Clinical Cancer Research Coordinating Center, Bern (Switzerland); Terribilini, Dario; Isaak, Bernhard [Division of Medical Radiation Physics, Inselspital, Bern University Hospital, and University of Bern, Bern (Switzerland); Gut, Philipp; Wolfensberger, Patrick; Broemme, Jens O.; Geretschlaeger, Andreas; Behrensmeier, Frank; Pica, Alessia; Aebersold, Daniel M. [Department of Radiation Oncology, Inselspital, Bern University Hospital, and University of Bern (Switzerland)

    2012-07-15

    Purpose: To analyze the outcome after low-dose-rate (LDR) or high-dose-rate (HDR) brachytherapy for lip cancer. Methods and Materials: One hundred and three patients with newly diagnosed squamous cell carcinoma of the lip were treated between March 1985 and June 2009 either by HDR (n = 33) or LDR brachytherapy (n = 70). Sixty-eight patients received brachytherapy alone, and 35 received tumor excision followed by brachytherapy because of positive resection margins. Acute and late toxicity was assessed according to the Common Terminology Criteria for Adverse Events 3.0. Results: Median follow-up was 3.1 years (range, 0.3-23 years). Clinical and pathological variables did not differ significantly between groups. At 5 years, local recurrence-free survival, regional recurrence-free survival, and overall survival rates were 93%, 90%, and 77%. There was no significant difference for these endpoints when HDR was compared with LDR brachytherapy. Forty-two of 103 patients (41%) experienced acute Grade 2 and 57 of 103 patients (55%) experienced acute Grade 3 toxicity. Late Grade 1 toxicity was experienced by 34 of 103 patients (33%), and 5 of 103 patients (5%) experienced late Grade 2 toxicity; no Grade 3 late toxicity was observed. Acute and late toxicity rates were not significantly different between HDR and LDR brachytherapy. Conclusions: As treatment for lip cancer, HDR and LDR brachytherapy have comparable locoregional control and acute and late toxicity rates. HDR brachytherapy for lip cancer seems to be an effective treatment with acceptable toxicity.

  14. Proceedings of the Second Congress of Radiochemotherapy and Brachytherapy and the Fifth Meeting of Medical Physics

    International Nuclear Information System (INIS)

    Zunino, Silvia; Venencia, Daniel; Martinez, Monica; Garrigo, Edgardo

    2009-01-01

    The Marie Curie Foundation in the city of Cordoba in Argentina, has organized the Second Congress of radiochemotherapy and brachytherapy and the Fifth Meeting of Medical Physics in order to collaborate with the scientific growth of radiation oncology and medical physics. The main topics covered were: patient's radioprotection, brachytherapy with iodine, radiation protection regulatory issues in Argentina, risk analysis in radiotherapy, medical radiation therapy, EPID dosimetry (Electronic Portal Image Device), accidents in radiotherapy, among others. [es

  15. Demonstration of brachytherapy boost dose-response relationships in glioblastoma multiforme

    International Nuclear Information System (INIS)

    Sneed, Penny K.; Lamborn, Kathleen R.; Larson, David A.; Prados, Michael D.; Malec, Mary K.; McDermott, Michael W.; Weaver, Keith A.; Phillips, Theodore L.; Wara, William M.; Gutin, Philip H.

    1996-01-01

    Purpose: To evaluate brachytherapy dose-response relationships in adults with glioblastoma undergoing temporary 125 I implant boost after external beam radiotherapy. Methods and Materials: Since June 1987, orthogonal radiographs using a fiducial marker box have been used to verify brain implant source positions and generate dose-volume histograms at the University of California, San Francisco. For adults who underwent brachytherapy boost for glioblastoma from June 1987 through December 1992, tumor volumes were reoutlined to ensure consistency and dose-volume histograms were recalculated. Univariate and multivariate analyses of various patient and treatment parameters were performed evaluating for influence of dose on freedom from local failure (FFLF) and actuarial survival. Results: Of 102 implant boosts, 5 were excluded because computer plans were unavailable. For the remaining 97 patients, analyses with adjustment for known prognostic factors (age, KPS, extent of initial surgical resection) and prognostic factors identified on univariate testing (adjuvant chemotherapy) showed that higher minimum brachytherapy tumor dose was strongly associated with improved FFLF (p = 0.001). A quadratic relationship was found between total biological effective dose and survival, with a trend toward optimal survival probability at 47 Gy minimum brachytherapy tumor dose (corresponding to about 65 Gy to 95% of the tumor volume); survival decreased with lower or higher doses. Two patients expired and one requires hospice care because of brain necrosis after brachytherapy doses > 63 Gy to 95% of the tumor volume with 60 Gy to > 18 cm 3 of normal brain. Conclusion: Although higher minimum brachytherapy tumor dose was strongly associated with better local control, a brachytherapy boost dose > 50-60 Gy may result in life-threatening necrosis. We recommend careful conformation of the prescription isodose line to the contrast enhancing tumor volume, delivery of a minimum brachytherapy

  16. Sci-Thur PM – Brachytherapy 04: Commissioning and Implementation of a Cobalt-60 High Dose Rate Brachytherapy Source

    Energy Technology Data Exchange (ETDEWEB)

    Dysart, Jonathan [Horizon Health Network (Canada)

    2016-08-15

    An Eckert & Ziegler Bebig Co0.A86 cobalt 60 high dose rate (HDR) brachytherapy source was commissioned for clinical use. Long-lived Co-60 HDR sources offer potential logistical and economic advantages over Ir-192 sources, and should be considered for low to medium workload brachytherapy departments where modest increases in treatment times are not a factor. In optimized plans, the Co-60 source provides a similar dose distribution to Ir-192 despite the difference in radiation energy. By switching to Co-60, source exchange frequency can be reduced by a factor of 20, resulting in overall financial savings of more than 50% compared to Ir-192 sources. In addition, a reduction in Physicist QA workload of roughly 200 hours over the 5 year life of the Co-60 source is also expected. These benefits should be considered against the modest increases in average treatment time compared to those of Ir-192 sources, as well as the centre-specific needs for operating room shielding modification.

  17. Comparação dos modelos prognósticos de Clutter e da função Logística

    Directory of Open Access Journals (Sweden)

    Juliana Carneiro Gonçalves

    2016-09-01

    Full Text Available O objetivo deste estudo foi comparar o desempenho de dois modelos não-lineares e o sistema de equações simultâneas de Clutter na progrnose do volume de madeira em povoamentos clonais e superestoocados de Eucalyptus spp no Espírito Santo, Brasil. Para fins de avaliação da qualidade dos ajustes e comparação dos modelos, foi utilizado o Erro Padrão da Média Percentual, os Critérios de Informação de Akaike e Bayesiano, complementados pela análise gráfica dos resíduos padronizados. A inclusão das covariáveis, sítio e área basal, nos sistemas não-lineares de projeção em volume garantiram uma melhoria expressiva na acurácia das estimativas para a função logística com erros reduzidos em até quatro vezes. Verificou-se ainda que a função logística com inclusão de variáveis foi altamente superior a sua forma original de ajuste e mais coerente quando comparada ao sistema de equações simultâneas de Clutter. Os resultados permitiram inferir ainda sobre a superioridade do sistema não-linear de modelagem indicando valores de incremento médio anual máximos próximos a 5 anos, o que o torna condizente com a realidade das plantações florestais de eucalipto para produção de biomassa no Brasil.

  18. Pulsed dose rate and fractionated high dose rate brachytherapy: choice of brachytherapy schedules to replace low dose rate treatments

    International Nuclear Information System (INIS)

    Visser, Andries G.; Aardweg, Gerard J.M.J. van den; Levendag, Peter C.

    1996-01-01

    Purpose: Pulsed dose rate (PDR) brachytherapy is a new type of afterloading brachytherapy (BT) in which a continuous low dose rate (LDR) treatment is simulated by a series of 'pulses,' i.e., fractions of short duration (less than 0.5 h) with intervals between fractions of 1 to a few hours. At the Dr. Daniel den Hoed Cancer Center, the term 'PDR brachytherapy' is used for treatment schedules with a large number of fractions (at least four per day), while the term 'fractionated high dose rate (HDR) brachytherapy' is used for treatment schedules with just one or two brachytherapy fractions per day. Both treatments can be applied as alternatives for LDR BT. This article deals with the choice between PDR and fractionated HDR schedules and proposes possible fractionation schedules. Methods and Materials: To calculate HDR and PDR fractionation schedules with the intention of being equivalent to LDR BT, the linear-quadratic (LQ) model has been used in an incomplete repair formulation as given by Brenner and Hall, and by Thames. In contrast to earlier applications of this model, both the total physical dose and the overall time were not kept identical for LDR and HDR/PDR schedules. A range of possible PDR treatment schedules is presented, both for booster applications (in combination with external radiotherapy (ERT) and for BT applications as a single treatment. Because the knowledge of both α/β values and the half time for repair of sublethal damage (T (1(2)) ), which are required for these calculations, is quite limited, calculations regarding the equivalence of LDR and PDR treatments have been performed for a wide range of values of α/β and T (1(2)) . The results are presented graphically as PDR/LDR dose ratios and as ratios of the PDR/LDR tumor control probabilities. Results: If the condition that total physical dose and overall time of a PDR treatment must be exactly identical to the values for the corresponding LDR treatment regimen is not applied, there appears

  19. Brachytherapy in childhood rhabdomyosarcoma treatment; Braquiterapia no tratamento do rabdomiossarcoma da infancia

    Energy Technology Data Exchange (ETDEWEB)

    Novaes, Paulo Eduardo Ribeiro dos Santos

    1995-07-01

    A retrospective study of 21 children with rhabdomyosarcoma treated by brachytherapy to the primary site of the tumor at the Radiotherapy Department of the A.C.Camargo Hospital between january/1980 to june/1993 was undertaken. The main objectives were to comprove the utility of brachytherapy in childhood rhabdomyosarcoma, to evaluate the local control and survival, in association with chemotherapy, to analyze the late effects of the treatment and to determinate the preferential technique to each clinical situation. All patients received brachytherapy to the tumor site. The radioactive isotopes employed were Gold{sup 198}, Cesium{sup 137} and Iridium{sup 192}. The brachytherapy techniques depended on the tumor site, period of treatment, availability of the radioactive material and stage of the disease. Patients treated exclusively by brachytherapy received 40 Gy to 60 Gy. When brachytherapy was associated with external radiotherapy the dose ranged from 20 Gy to 40 Gy. Local control was achieved in 18 of 20 patients (90%). The global survival and local control survival rates were 61.9% (13/21 patients) and 72,2% (13/18 patients) respectively. (author)

  20. Adherence to Vaginal Dilation Following High Dose Rate Brachytherapy for Endometrial Cancer

    International Nuclear Information System (INIS)

    Friedman, Lois C.; Abdallah, Rita; Schluchter, Mark; Panneerselvam, Ashok; Kunos, Charles A.

    2011-01-01

    Purpose: We report demographic, clinical, and psychosocial factors associated with adherence to vaginal dilation and describe the sexual and marital or nonmarital dyadic functioning of women following high dose rate (HDR) brachytherapy for endometrial cancer. Methods and Materials: We retrospectively evaluated women aged 18 years or older in whom early-stage endometrial (IAgr3-IIB) cancers were treated by HDR intravaginal brachytherapy within the past 3.5 years. Women with or without a sexual partner were eligible. Patients completed questionnaires by mail or by telephone assessing demographic and clinical variables, adherence to vaginal dilation, dyadic satisfaction, sexual functioning, and health beliefs. Results: Seventy-eight of 89 (88%) eligible women with early-stage endometrial cancer treated with HDR brachytherapy completed questionnaires. Only 33% of patients were adherers, based on reporting having used a dilator more than two times per week in the first month following radiation. Nonadherers who reported a perceived change in vaginal dimension following radiation reported that their vaginas were subjectively smaller after brachytherapy (p = 0.013). Adherers reported more worry about their sex lives or lack thereof than nonadherers (p = 0.047). Patients reported considerable sexual dysfunction following completion of HDR brachytherapy. Conclusions: Adherence to recommendations for vaginal dilator use following HDR brachytherapy for endometrial cancer is poor. Interventions designed to educate women about dilator use benefit may increase adherence. Although sexual functioning was compromised, it is likely that this existed before having cancer for many women in our study.

  1. Efficacy of prophylactic single-dose therapy using fluoroquinolone for prostate brachytherapy

    International Nuclear Information System (INIS)

    Nomura, Takeo; Hirai, Kenichi; Yamasaki, Mutsushi; Inoue, Toru; Takahashi, Mika; Kawashima, Takayuki; Sato, Fuminori; Mimata, Hiromitsu

    2012-01-01

    There is little definitive evidence to guide the use of prophylactic antibiotics for prostate brachytherapy. The purpose of this study is to evaluate the incidence of postimplant infections in patients who receive antimicrobial prophylaxis with pazufloxacin (PZFX). A total of 84 patients who underwent prostate brachytherapy received a single intravenous dose of PZFX at 500 mg perioperatively for 1 day. No postimplant antibiotic medication was prescribed. Urinalysis, plasma white blood cell (WBC) count, and C reactive protein (CRP) levels were evaluated before the implantation, on the day after implantation, and on the 7th and 28th days after brachytherapy. None of the 84 patients (0.0%) developed a symptomatic urinary tract infection or had febrile infectious complications after brachytherapy. There were statistically significant elevations in the levels of erythrocytes, leukocytes, bacteria in urine, plasma WBC and CRP postoperatively, but these values did not exceed the normal range or were only slightly elevated on the day after brachytherapy (day 1) and on day 7. All laboratory examinations had returned to the normal range on day 28. Single-dose therapy with fluoroquinolone helps to prevent infections after prostate brachytherapy. (author)

  2. Perioperative Search for Circulating Tumor Cells in Patients Undergoing Prostate Brachytherapy for Clinically Nonmetastatic Prostate Cancer

    Directory of Open Access Journals (Sweden)

    Hideyasu Tsumura

    2017-01-01

    Full Text Available Despite the absence of local prostate cancer recurrence, some patients develop distant metastases after prostate brachytherapy. We evaluate whether prostate brachytherapy procedures have a potential risk for hematogenous spillage of prostate cancer cells. Fifty-nine patients who were undergoing high-dose-rate (HDR or low-dose-rate (LDR brachytherapy participated in this prospective study. Thirty patients with high-risk or locally advanced cancer were treated with HDR brachytherapy after neoadjuvant androgen deprivation therapy (ADT. Twenty-nine patients with clinically localized cancer were treated with LDR brachytherapy without neoadjuvant ADT. Samples of peripheral blood were drawn in the operating room before insertion of needles (preoperative and again immediately after the surgical manipulation (intraoperative. Blood samples of 7.5 mL were analyzed for circulating tumor cells (CTCs using the CellSearch System. While no preoperative samples showed CTCs (0%, they were detected in intraoperative samples in 7 of the 59 patients (11.8%; preoperative vs. intraoperative, p = 0.012. Positive CTC status did not correlate with perioperative variables, including prostate-specific antigen (PSA at diagnosis, use of neoadjuvant ADT, type of brachytherapy, Gleason score, and biopsy positive core rate. We detected CTCs from samples immediately after the surgical manipulation. Further study is needed to evaluate whether those CTCs actually can survive and proliferate at distant sites.

  3. Quality control of brachytherapy equipment in the Netherlands and Belgium: current practice and minimum requirements

    International Nuclear Information System (INIS)

    Elfrink, Robert J.M.; Kolkman-Deurloo, Inger-Karine K.; Kleffens, Herman J. van; Rijnders, Alex; Schaeken, Bob; Aalbers, Tony H.L.; Dries, Wim J.F.; Venselaar, Jack L.M.

    2002-01-01

    Background and purpose: Brachytherapy is applied in 39 radiotherapy institutions in The Netherlands and Belgium. Each institution has its own quality control (QC) programme to ensure safe and accurate dose delivery to the patient. The main goal of this work is to gain insight into the current practice of QC of brachytherapy in The Netherlands and Belgium and to reduce possible variations in test frequencies and tolerances by formulating a set of minimum QC-requirements. Materials and methods: An extensive questionnaire about QC of brachytherapy was distributed to and completed by the 39 radiotherapy institutions. A separate smaller questionnaire was sent to nine institutions performing intracoronary brachytherapy. The questions were related to safety systems, physical irradiation parameters and total time spent on QC. The results of the questionnaires were compared with recommendations given in international brachytherapy QC reports. Results: The answers to the questionnaires showed large variations in test frequencies and test methods. Furthermore, large variations in time spent on QC exist, which is mainly due to differences in QC-philosophy and differences in the available resources. Conclusions: Based on the results of the questionnaires and the comparison with the international recommendations, a set of minimum requirements for QC of brachytherapy has been formulated. These guidelines will be implemented in the radiotherapy institutions in The Netherlands and Belgium

  4. Palliative brachytherapy with or without primary stent placement in patients with oesophageal cancer, a randomised phase III trial

    International Nuclear Information System (INIS)

    Amdal, Cecilie Delphin; Jacobsen, Anne-Birgitte; Sandstad, Berit; Warloe, Trond; Bjordal, Kristin

    2013-01-01

    Purpose: To investigate whether a combination of self-expanding metal stent (SEMS) and brachytherapy provided more rapid and prolonged effect on dysphagia without increased pain compared to brachytherapy alone in patients with incurable oesophageal cancer. Methods: 41 Patients were randomised to SEMS followed by brachytherapy, 8 Gy × 3 (n = 21) or brachytherapy alone, 8 Gy × 3 (n = 20). Change in dysphagia and pain three and seven weeks after randomisation (FU1 and FU2) was assessed by patient-reported outcome. Dysphagia, other symptoms and health-related quality of life were assessed every four weeks thereafter. The study was closed before the estimated patient-number was reached due to slow recruitment. Results: Patients receiving SEMS followed by brachytherapy had significantly improved dysphagia at FU1 compared to patients receiving brachytherapy alone (n = 35). Difference in pain was not observed. At FU2, patients in both arms (n = 21) had less dysphagia. Four patients in the combined treatment arm experienced manageable complications, no complications occurred after brachytherapy alone. Conclusion: For the relief of dysphagia, SEMS followed by brachytherapy is preferable and safe for patients in need of immediate alleviation, while brachytherapy with or without preceding SEMS provides relief within a few weeks after treatment

  5. Optimum plastic scintillator and optical fiber combination for brachytherapy dosimetry

    International Nuclear Information System (INIS)

    Arnfield, Mark R.; Gaballa, Hani E.; Zwicker, Robert D.; Islam, Quazi; Schmidt-Ullrich, Rupert

    1995-01-01

    Purpose/Objective: There have been several recent reports using plastic scintillators to measure dose in photon and electron beams. External beam measurements agreed well with standard ion chamber dosimetry. This was implemented by using two identical, parallel optical fibers with a small piece of plastic scintillator attached to one. We have constructed a similar device for application to brachytherapy. Brachytherapy dosimetry is a more difficult problem than external beam because of high dose gradients and widely ranging photon energies. Based on detailed spectral measurements, we have designed a dosimeter specifically to meet the unique, stringent needs of brachytherapy. Materials and Methods: The work consisted of two stages. In the first stage, we measured the optical spectra emitted by commercial plastic scintillators and silica core optical fibers in the presence of a 10 Curie iridium 192 HDR source. In the second stage, the spectral information was used to select an optimum combination of scintillator and fiber which were incorporated in the dosimeter. Equipment for the spectral measurements included a 0.1 meter monochromator with a sensitive photomultiplier (PMT) with flat response across the visible. The resolution of spectral scans was 4 nm. The dosimeter was constructed with a 1mm x 3mm piece of plastic scintillator bonded with optical cement to a 0.6 mm diameter silica core optical fiber. A second, identical optical fiber running alongside the first, with no scintillator attached, was used for background subtraction. Two PMTs with high sensitivity in the visible were used at the fiber distal ends. There was a space for an optical filter between the fiber and the PMTs, whose purpose is described below. The PMTs were connected to a differential pair whose output was transferred to a current source for measurement by a standard electrometer. Results: The scintillation spectra of six different types of silica core optical fibers in the presence of the

  6. Curative high dose rate vaginal apex brachytherapy in stage I papillary serous carcinoma of the endometrium

    International Nuclear Information System (INIS)

    Turner, B.C.; Kacinski, B.M.; Gumbs, A.; Peschel, R.E.; Haffty, B.G.; Wilson, L.D.

    1996-01-01

    Introduction: Uterine papillary serous carcinoma (UPSC) is a morphologically distinct variant of endometrial carcinoma that is associated with a poor prognosis, high recurrence rate, clinical understaging, and poor response to salvage treatment. We describe the presentation, local and distant control, survival, salvage rate, and complications for patients undergoing whole abdominal radiation therapy (WART), low dose rate (LDR) intracavitary brachytherapy, or high dose rate (HDR) vaginal brachytherapy in patients with stage I UPSC. Methods: Between 1976 and 1994 more than 1700 patients with endometrial carcinoma were treated with radiation therapy, 30 patients with stage I UPSC (1.8%) were treated with radiation before or following TAH/BSO. All patients underwent either preoperative Simon's packing or tandem and plaque which delivered 30-40 Gy to the serosa, WART, or HDR Ir-192 vaginal apex brachytherapy to a total dose of 21 Gy in 3 fractions at 0.5 cm from the vaginal mucosa. A total of 14 patients received HDR vaginal brachytherapy and (5(14)) patients received systemic chemotherapy. All patients presented with vaginal bleeding at a median age of 67 years (range 34-88). The group of 30 patients underwent TAH/BSO, 17 patients were completely staged pathologically (pelvic and para-aortic lymph nodes, omentectomy, and pelvic washings), and 2 patients underwent omental biopsy and pelvic washings only. All specimens revealed UPSC, nuclear grade 3, and lymphovascular invasion (23%). The pathologic stage was IA: 23% (7), IB: 67% (20), and IC: 10% (3). The median follow-up for all patients was 49 months (range 13-187 months). For the patients receiving postoperative HDR vaginal brachytherapy the median time from surgery to radiation was 42 days (range 29-91). Results: The 5-year actuarial disease free survival for Figo stage I UPSC patients treated with postoperative HDR vaginal brachytherapy and systemic chemotherapy was 100% compared to 74% for stage I UPSC patient

  7. Combination of biodegradable stent placement and single-dose brachytherapy is associated with an unacceptably high complication rate in the treatment of dysphagia from esophageal cancer

    NARCIS (Netherlands)

    Hirdes, Meike M. C.; van Hooft, Jeanin E.; Wijrdeman, Harm K.; Hulshof, Maarten C. C. M.; Fockens, Paul; Reerink, Onne; van Oijen, Martijn G. H.; van der Tweel, Ingeborg; Vleggaar, Frank P.; Siersema, Peter D.

    2012-01-01

    Background: For the palliative treatment of dysphagia, esophageal stent placement provides immediate improvement, whereas brachytherapy offers better long-term relief. Objective: To evaluate safety and efficacy of concurrent brachytherapy and biodegradable stent placement. Design: Prospective,

  8. Critical Organ Preservation in Reirradiation Brachytherapy by Injectable Spacer

    International Nuclear Information System (INIS)

    Kishi, Kazushi; Sonomura, Tetsuo; Shirai, Shintaro; Sato, Morio; Tanaka, Kayo

    2009-01-01

    Purpose: This case series study evaluated the feasibility and effectiveness of an interstitial high-dose rate brachytherapy (HDR-BT) procedure combined with an at-risk organ-sparing procedure. Methods and Materials: Thirty patients who were scheduled for reirradiation treatment for recurrent cancer after receiving a median dose of 60 Gy (range, 44-70 Gy) in 2-Gy fractions of previous external beam treatment were enrolled. Thirteen patients had lesions in the head and neck, and other lesions were located in the axilla, skeleton, breast, pelvis, and abdominal wall. Chief complaints included local masses (for 25) and refractory pain (for 21). After high-dose rate brachytherapy applicator needle implantation, an optimal CT-based three-dimensional brachytherapy plan was created with a virtual at-risk organ shift from the target. According to the plan, hyaluronic acid gel was injected to maintain the shift during irradiation. The prescribed dose was the result of an individualized tradeoff between target dose and at-risk organ dose, to avoid serious complications. A single-fraction dose of 18.0 Gy (median, equivalent to 75.6 Gy at an α/β value of 3; range, 16-20 Gy) was applied to the tumor. Results: The at-risk organ dose decreased from 9.1 ± 0.9 Gy to 4.4 ± 0.4 Gy (mean ± standard deviation, p < 0.01), and the normal tissue complication probability decreased from 60.8% ± 12.6% to 16.1% ± 19.8% (p < 0.01). The shift effect lasted at least 4 hours and disappeared gradually. Distinct tumor shrinkage in 20 of 21 eligible patients, including tumor disappearance in 6 patients, pain reduction in 18 of 21 eligible patients, and no unexpected late toxicity greater than grade 2 were observed during the 19.5-month observation period. Conclusions: This at-risk organ-sparing preservation procedure may provide a safe and efficient reirradiation treatment.

  9. HDR intralumenal brachytherapy in bronchial cancer: review of our experience

    International Nuclear Information System (INIS)

    Muto, P.; Ravo, V.; Muschera, R.

    1996-01-01

    The main indications for brachytherapy in the treatment of endobronchial cancer are dyspnea. postobstructive pneumonia and atelectasis, cough and hemoptysis resulting from broncus obstruction by exophytic intralumenal tumor growth. High Dose Rate intralumenal brachytherapy (HDRBT) may be combined with external beam radiotherapy (EBRT), in particular as almost all tumors are too large for HDRBT alone. From January 1992 to September 1995 we treated 268 patients affected by bronchial cancer, with EBRT combined with HDRBT. All patients were staged as IIIa-IIIb-IV but KPS was >60 and expectancy of life > than 3 months. After bronchoscopy and Tc simulation we found that almost 10% of patients were downstaged. Treatment was always realized delivering 60 Gy to the tumour volume and 50 Gy to the mediastinal structures with EBRT. Brachytherapy was performed during the radiotherapy course. In 38 patients HDRBT was realized just one time, at the beginning of EBRT, with a dose of 10 Gy calculated at 1cm from the central axis of the catheter. In 47 HDRBT was performed twice (at the beginning and at the end of EBRT) with a dose of 7 Gy calculated at 1 cm from the central axis. From 1994 we started a 3 fractions protocol (Timing: days 1.15.30) with a dose of 5 Gy calculated at 0.5 cm from the axis. Of the 183 patients introduced in the protocol 170 received the three fractions of HDRBT and 13 were excluded from the study for personal or clinical reasons. In 97% of cases the application did not need general anesthesia; local anesthesia has been sufficient supplemented by some drug for sedation and coughing. Anyway both bronchoscopy and HDRBT (with anterior-posterior and lateral chest X-ray) are performed in the same shielded room without the necessity of displacing the patient. In almost 60% of treatments we used just one endobronchial applicator. In case of tumor involvement of the carina, two applicators were introduced. By this a larger tumor volume can be treated with adequate

  10. Primary Causes of Death After Permanent Prostate Brachytherapy

    International Nuclear Information System (INIS)

    Bittner, Nathan; Merrick, Gregory S.; Galbreath, Robert W.; Butler, Wayne M.; Wallner, Kent E.; Allen, Zachariah A.; Brammer, Sarah G.; Moyad, Mark

    2008-01-01

    Purpose: To evaluate the primary causes of death in low-risk (low-risk), intermediate-risk (intermediate-risk), and high-risk (high-risk) patients undergoing permanent prostate brachytherapy with or without supplemental therapies. Methods and Materials: From April 1995 through November 2004, a total of 1,354 consecutive patients underwent prostate brachytherapy. All patients underwent brachytherapy >3 years before analysis. Of the patients, 532 (39.3%) received androgen deprivation therapy and 703 (51.9%) received supplemental radiation therapy. The median follow-up was 5.4 years. Multiple parameters were evaluated as predictors of cause-specific, biochemical progression-free, and overall survival. Results: The 10-year cause-specific survival was 97.0% (99.7%, 99.0%, and 90.1% for low-risk, intermediate-risk, and high-risk patients). Overall survival was 76.7% (82.5%, 78.3%, and 67.6% for low-, intermediate-, and high-risk patients, respectively). The cumulative death rate for cardiovascular disease was 11.5% (8.7%, 9.3%, and 19.8% for low-, intermediate-, and high-risk patients). The death rate from second malignancies (nonprostate cancer) was 7.2% and was not substantially different when stratified by risk group. Death from all other causes was 6.5% for the entire cohort but 1.3%, 5.0%, and 10.8% for low-, intermediate-, and high-risk patients. In multivariate analysis, death from prostate cancer was best predicted by Gleason score and risk group, whereas death from cardiovascular disease, nonprostate cancer, and all other causes were most closely related to patient age and tobacco use. Conclusions: Although cardiovascular mortality was the predominant cause of death, prostate cancer was responsible for approximately 10% of all deaths. In particular, overall survival was poorest in the high-risk group. Although high-risk patients were most likely to die of prostate cancer, the divergence in overall survival between high-risk and lower-risk patients primarily

  11. Effectiveness of brachytherapy in treating carcinoma of the vulva

    International Nuclear Information System (INIS)

    Pohar, Surjeet; Hoffstetter, Sylvette; Peiffert, Didier; Luporsi, Elisabeth; Pernot, Monique

    1995-01-01

    Purpose: Radical radiotherapeutic management of vulvar cancer often incorporates brachytherapy as a portion of the treatment regimen. However, few studies using this modality alone to manage vulvar cancer have been published. Methods and Materials: Thirty four patients were treated with iridium-192 ( 192 Ir) brachytherapy for vulvar cancer between 1975 and 1993 at Centre Alexis Vautrin. Twenty-one patients were treated at first presentation when surgery was contraindicated or declined. Of these patients, 12 had International Federation of Gynecology and Obstetrics Classification Stage III or IV disease, 8 were Stage II, 1 was Stage I, and 1 was Stage 0. Thirteen patients were treated for recurrent disease. Paris system rules for implantation and dose prescription were followed. The median reference dose was 60 Gy (range 53 to 88 Gy). At the time of analysis, 10 of 34 patients were alive. Median follow-up in these 10 patients was 31 months (range: 21 months to 107 months). Fourteen of the 24 deaths were from causes other than vulvar cancer. Results: Kaplan-Meier actuarial 5-year local control was 47% (95% confidence interval (CI) = 23 to 73%) and 5-year actuarial loco-regional control was 45% (95% CI = 21 to 70%). Kaplan-Meier actuarial 5-year disease-specific survival was 56% (95% CI = 33 to 76%) and actuarial 5-year survival was 29% (95% CI = 15 to 49%). Median time to death was 14 months. Subset analysis revealed a higher actuarial 5-year local control in patients treated at first presentation than those treated for recurrence (80 vs. 19%, log rank, p = 0.04). Similarly, actuarial 5-year loco-regional control was higher in patients treated at first presentation (80 vs. 16%, log rank, p 0.01). The two groups did not differ significantly in disease-specific or overall survival. The actuarial 5-year disease specific survival of 56% is somewhat less than the expected 5-year disease-specific survival after surgery in a group having a similar proportion of early stage

  12. Commissioning and clinical implementation of HDR brachytherapy in El Salvador

    International Nuclear Information System (INIS)

    Morales Lopez, Jorge Luis; Castillo, Luis Frank; Castillo Bahi, Ramon del

    2009-01-01

    The Gynecologic Cancer is one of the best known malignancies in different countries of the world, with a high incidence in developing countries. In the treatment of this disease have been used multiple treatment arms among which is the high rate brachytherapy (HDR). The IAEA has put much emphasis on supporting all programs to treat this disease and in this context within the project 'Human Resource Development and Nuclear Technology Support', collaborated with the dispatch of experts on mission ELS0006 01 'Assistance to the ICES in HDR brachytherapy initiating Treatments at the Cancer Institute of El Salvador 'Dr. Narciso Diaz Bazan' in San Salvador, El Salvador. The process of commissioning and implementing clinical service Brachytherapy High Dose Rate (HDR BT) is a relatively complex process that begins with the formation of functional and technical service, based on flow patients to be treated, availability of local technological capability to install, and culminates with the preparation and implementation of protocols. Experts involved in the implementation of this service divided this task in stages organized chronologically: 1st. Study of existing infrastructure and level of training of technical personnel available, 2nd. Proposal and application of amendments in order to adapt the facility to the planned patient flow and optimal use of technological infrastructure, 3rd. Establishment of the process of securing the disposable waste materials and not required, 4th. Performance of tests of physical commissioning clinical dosimetry and instrumentation unit, surgical and therapeutic, 5th. Training of technical personnel, 6th. Preparation of clinical protocol and 7th. Initiation and development of treatment for patients. All these steps are carried out with the integration and consensus of the entire multidisciplinary team that makes up the service and with the support of the administration as a prerequisite. Within two weeks the service was modified according to

  13. Outcomes and toxicities in patients with intermediate-risk prostate cancer treated with brachytherapy alone or brachytherapy and supplemental external beam radiation therapy.

    Science.gov (United States)

    Schlussel Markovic, Emily; Buckstein, Michael; Stone, Nelson N; Stock, Richard G

    2018-05-01

    To evaluate the cancer control outcomes and long-term treatment-related morbidity of brachytherapy as well as combination brachytherapy and external beam radiation therapy (EBRT) in patients with intermediate-risk prostate cancer. A retrospective review was conducted in a prospectively collected database of patients with intermediate-risk prostate cancer who were treated either with brachytherapy or brachytherapy and EBRT, with or without androgen deprivation therapy (ADT), in the period 1990-2014. Urinary and erectile dysfunction symptoms were measured using the International Prostate Symptom Score (IPSS), the Mount Sinai erectile function scale and the Sexual Health Inventory for Men (SHIM). Cancer control endpoints included biochemical failure and development of distant metastases. All statistical analyses were carried out using the Statistical Package for Social Science (SPSS). Survival curves were calculated using Kaplan-Meier actuarial methods and compared using log-rank tests. Cox regression multivariate analyses were used to test the effect of multiple variables on treatment outcomes. A total of 902 patients were identified, with a median follow-up of 91 months. Of these, 390 received brachytherapy and 512 received combination therapy with EBRT. In patients with one intermediate-risk factor, the addition of EBRT did not significantly affect freedom from biochemical failure or distant metastases. Among patients with two or three intermediate-risk factors, added EBRT did not improve freedom from biochemical failure. Significant differences in late toxicity between patients treated with brachytherapy vs combination brachytherapy and EBRT were identified including urge incontinence (P actuarial methods showed that patients receiving combination therapy more frequently experienced loss of potency, as measured by the Mount Sinai erectile function scale (P = 0.040). Brachytherapy monotherapy results in equal biochemical and distant control in both patients with

  14. Cálculo, mediante la aplicación del algoritmo de ajuste por mínimos cuadrados, de los componentes de velocidad para estaciones GNSS continuas

    Directory of Open Access Journals (Sweden)

    Jorge Moya Zamora

    2014-07-01

    Full Text Available El cálculo de la velocidad de una estación de observación continua GNSS representa un insumo fundamental en la geodesia moderna. El hecho de determinar la posición de las estaciones GNSS de forma diaria implica que se puedan establecer las series temporales de las estaciones, con base en las cuales se puede obtener información de la influencia de fenómenos que afecten el comportamiento de estas. En este artículo se plantea una descripción del algoritmo de ajuste por mínimos cuadrados adaptado y aplicado a la determinación de los componentes de velocidad de estaciones de observación continua. Además, se aplica este algoritmo para la calcular la velocidad de la estación ETCG, perteneciente al Sistema Geocéntrico para las Américas (SIRGAS.

  15. AJUSTE DE ECUACIONES DE BIOMASA PARA Pinus durangensis (Martínez M. EN LA REGIÓN DE EL SALTO, DURANGO

    Directory of Open Access Journals (Sweden)

    E. Montes de Oca-Cano

    2009-01-01

    Full Text Available El objetivo del presente estudio fue ajustar ecuaciones lineales y no lineales para estimar biomasa por componente de hojas, ramas, fuste y total, para árboles con edades entre tres y diez años, en la región de El Salto, Dgo. Los resultados indican que las ecuaciones se ajustan mejor a nivel individual, el componente total muestra los mejores estadísticos de ajuste, mientras que las mayores variaciones se detectan en las ramas y en el fuste. Adicionalmente se analizan porcentajes de biomasa por componente donde se observa que el fuste aporta 46.9 % de la biomasa, las hojas 35.6 % y las ramas solamente 17.3 % de la biomasa total. Así mismo, dentro del rango de edad analizado, la biomasa en el fuste aumenta anualmente 2.96 %; la biomasa en las hojas disminuye 3.13 % y la biomasa en las ramas aumenta 0.17 %.

  16. Ausentismo y producción: el esquema de ajuste de primas por siniestralidad observada aplicado al seguro de salud en Francia

    Directory of Open Access Journals (Sweden)

    Sébastien Ménard

    2018-01-01

    Full Text Available En este trabajo se analizan los efectos de la introducción de un esquema de ajuste (experience rating en las contribuciones patronales al seguro de salud. Para ello, se desarrolla un modelo de búsqueda y emparejamiento en un mercado de trabajo segmentado. En el segmento donde los empleos son más riesgosos, las ausencias por enfermedad son más frecuentes y la producción media es más baja. El modelo es calibrado para Francia y los resultados de las simulaciones muestran que la introducción de este esquema mejora levemente la producción y el empleo. En términos cuantitativos, una variación del 1 % en la tasa de experience rating induce una reducción de 0,48 % en la duración del desempleo y de 1,07 % en los días de ausencia, así como un aumento de 0,1 % en la producción. Finalmente, se encuentra que esta política conduce también a un desempeño económico ligeramente mejor que la privatización del seguro de salud

  17. Series de días hábiles en Colombia: una aplicación al ajuste del crecimiento industrial

    Directory of Open Access Journals (Sweden)

    Álvaro Montenegro García

    2014-06-01

    Full Text Available Si bien muchos economistas son conscientes del efecto de los días hábiles sobre la medición de la producción, aún es frecuente encontrar que estas cifras se analizan sin el correspondiente ajuste. En general, el número de días hábiles en un mes cambia de un año a otro, lo cual es cierto para todos los meses, no solo para los que contienen la Semana Santa. Este trabajo recopila la serie de días hábiles mensuales tomando en cuenta los festivos actuales y anteriores a la Ley Emiliani, y la utiliza para ajustar la serie de producción manufacturera del DANE. Para algunos meses, la diferencia entre la cifra de crecimiento industrial reportada por el DANE y la cifra ajustada por días hábiles puede acercarse a los 12 puntos porcentuales, en cualquier dirección

  18. Low-Dose-Rate Brachytherapy Versus Cryotherapy in Low- and Intermediate-Risk Prostate Cancer

    International Nuclear Information System (INIS)

    Gestaut, Matthew M.; Cai, Wendi; Vyas, Shilpa; Patel, Belur J.; Hasan, Salman A.; MunozMaldonado, Yolanda; Deb, Niloyjyoti; Swanson, Gregory

    2017-01-01

    Purpose: Cryotherapy and brachytherapy are definitive local treatment options for low- to intermediate-risk prostate cancer. There are both prospective and retrospective data for brachytherapy, but the use of cryotherapy has been limited primarily to single-institution retrospective studies. Currently, no published evidence has compared low-dose-rate brachytherapy versus cryotherapy. Methods and Materials: Institutional review board approval was obtained to conduct a retrospective chart review of consecutive patients treated at our institution from 1990 to 2012. For inclusion, patients must have received a prostate cancer diagnosis and have been considered to have low- to intermediate-risk disease according to the National Comprehensive Cancer Network criteria. All patients received brachytherapy or cryotherapy treatment. Disease specifics and failure details were collected for all patients. Failure was defined as prostate-specific antigen nadir +2 ng/mL. Results: A total of 359 patients were analyzed. The groups comprised 50 low-risk cryotherapy (LRC), 92 intermediate-risk cryotherapy (IRC), 133 low-risk brachytherapy (LRB), and 84 intermediate-risk brachytherapy (IRB) patients. The median prostate-specific antigen follow-up periods were 85.6 months (LRC), 59.2 months (IRC), 74.9 months (LRB), and 59.8 months (IRB). The 5-year biochemical progression–free survival (bPFS) rate was 57.9% in the cryotherapy group versus 89.6% in the brachytherapy group (P<.0001). The 5-year bPFS rate was 70.0% (LRC), 51.4% (IRC), 89.4% (LRB), and 89.7% (IRB). The bPFS rate was significantly different between brachytherapy and cryotherapy for low- and intermediate-risk groups (P<.05). The mean nadir temperature reached for cryotherapy patients was −35°C (range, −96°C to −6°C). Cryotherapy used a median of 2 freeze-thaw cycles (range, 2-4 freeze-thaw cycles). Conclusions: Results from this study suggest that cryotherapy is inferior to brachytherapy for patients with

  19. Inverse planning in brachytherapy from radium to high rate 192 iridium afterloading

    International Nuclear Information System (INIS)

    Lahanas, M.; Mould, R.F.; Baltas, D.; Karauzakis, K.; Giannouli, S.; Baltas, D.

    2004-01-01

    We consider the inverse planning problem in brachytherapy, i.e. the problem to determine an optimal number of catheters, number of sources for low-dose rate brachytherapy (LDR) and the optimal dwell times for high-dose rate brachytherapy (HDR) necessary to obtain an optimal as possible dose distribution. Starting from the 1930s, inverse planning for LDR brachytherapy used geometrically derived rules to determine the optimal placement of sources in order to achieve a uniform dose distribution of a specific level in planes, spheres and cylinders. Rules and nomograms were derived which still are widely used. With the rapid development of 3D imaging technologies and the rapidly increasing computer power we have now entered the new era of computer-based inverse planning in brachytherapy. The inverse planning is now an optimisation process adapted to the individual geometry of the patient. New inverse planning optimisation algorithms are anatomy-based that consider the real anatomy of the tumour and the organs at risk (OAR). Computer-based inverse planning considers various effects such as stability of solutions for seed misplacements which cannot ever be solved analytically without gross simplifications. In the last few years multiobjective (MO) inverse planning algorithms have been developed which recognise the MO optimisation problem which is inherent in inverse planning in brachytherapy. Previous methods used a trial and error method to obtain a satisfactory solution. MO optimisation replaces this trial and error process by presenting a representative set of dose distributions that can be obtained. With MO optimisation it is possible to obtain information that can be used to obtain the optimum number of catheters, their position and the optimum distribution of dwell times for HDR brachytherapy. For LDR brachytherapy also the stability of solutions due to seed migration can also be improved. A spectrum of alternative solutions is available and the treatment planner

  20. Low-Dose-Rate Brachytherapy Versus Cryotherapy in Low- and Intermediate-Risk Prostate Cancer

    Energy Technology Data Exchange (ETDEWEB)

    Gestaut, Matthew M., E-mail: Matthew.Gestaut@BSWHealth.org [Department of Radiation Oncology, Baylor Scott and White Memorial Hospital, Texas A& M University School of Medicine, Temple, Texas (United States); Cai, Wendi [Department of Biostatistics, Baylor Scott and White Health, Temple, Texas (United States); Vyas, Shilpa [Department of Radiation Oncology, Swedish Cancer Institute, Seattle, Washington (United States); Patel, Belur J. [Department of Urology, Baylor Scott and White Memorial Hospital, Texas A& M University School of Medicine, Temple, Texas (United States); Hasan, Salman A. [Department of Radiation Oncology, Baylor Scott and White Memorial Hospital, Texas A& M University School of Medicine, Temple, Texas (United States); MunozMaldonado, Yolanda [Department of Biostatistics, Baylor Scott and White Health, Temple, Texas (United States); Deb, Niloyjyoti; Swanson, Gregory [Department of Radiation Oncology, Baylor Scott and White Memorial Hospital, Texas A& M University School of Medicine, Temple, Texas (United States)

    2017-05-01

    Purpose: Cryotherapy and brachytherapy are definitive local treatment options for low- to intermediate-risk prostate cancer. There are both prospective and retrospective data for brachytherapy, but the use of cryotherapy has been limited primarily to single-institution retrospective studies. Currently, no published evidence has compared low-dose-rate brachytherapy versus cryotherapy. Methods and Materials: Institutional review board approval was obtained to conduct a retrospective chart review of consecutive patients treated at our institution from 1990 to 2012. For inclusion, patients must have received a prostate cancer diagnosis and have been considered to have low- to intermediate-risk disease according to the National Comprehensive Cancer Network criteria. All patients received brachytherapy or cryotherapy treatment. Disease specifics and failure details were collected for all patients. Failure was defined as prostate-specific antigen nadir +2 ng/mL. Results: A total of 359 patients were analyzed. The groups comprised 50 low-risk cryotherapy (LRC), 92 intermediate-risk cryotherapy (IRC), 133 low-risk brachytherapy (LRB), and 84 intermediate-risk brachytherapy (IRB) patients. The median prostate-specific antigen follow-up periods were 85.6 months (LRC), 59.2 months (IRC), 74.9 months (LRB), and 59.8 months (IRB). The 5-year biochemical progression–free survival (bPFS) rate was 57.9% in the cryotherapy group versus 89.6% in the brachytherapy group (P<.0001). The 5-year bPFS rate was 70.0% (LRC), 51.4% (IRC), 89.4% (LRB), and 89.7% (IRB). The bPFS rate was significantly different between brachytherapy and cryotherapy for low- and intermediate-risk groups (P<.05). The mean nadir temperature reached for cryotherapy patients was −35°C (range, −96°C to −6°C). Cryotherapy used a median of 2 freeze-thaw cycles (range, 2-4 freeze-thaw cycles). Conclusions: Results from this study suggest that cryotherapy is inferior to brachytherapy for patients with

  1. Design and implementation of an intravascular brachytherapy installation in cardiology

    International Nuclear Information System (INIS)

    Prieto, C.; Vano, E.; Fernandez, J.M.; Sabate, M.; Galvan, Y.C.

    2001-01-01

    Intravascular Brachytherapy (IVB) is a very promising technique for reducing restenosis rates. However, neither the exact absolute dose needed nor the optimal spatial and temporal distribution of dose inside the vessel wall for a successful treatment, nor the physical dosimetry of the various radioactive sources and devices for dose delivery, are well known. In this paper, an overview will be given of the design strategy, the dosimetric and radiation protection-related problems that we have met during the implementation of this technique at San Carlos hospital, adopted or foreseen solutions, and future research fields that we intend to carry out in order to reduce uncertainties and to achieve a deeper knowledge of the parameters that have an influence on the treatment. (author)

  2. Optimization in brachytherapy with the implementation of Radiobiology

    International Nuclear Information System (INIS)

    Duran, M.P.; Bourel, V.J.; Rodriguez, I.; Torre, M. de la; Caneva, S.

    1998-01-01

    In the brachytherapy planning treatments with High dose rates (HDR), the optimization algorithms used are based in dosimetric considerations and/or geometric ones, ignoring the radiobiological response of the tissue treated. In this work we wish to show the implementation of radiobiological concepts in the optimization. Assuming that the subtiles differences that result in the dose distribution among the different optimization models which are not visible in an isodose plane, it is studied how is classically make it , the quality implant through natural histograms about dose volumes and the resulting parameters. Also is studied the necrosis probability which may be caused by the choice of some optimization model, allowing with this the choice of the best implant. (Author)

  3. Evaluating the cost of therapy for restenosis: considerations for brachytherapy

    International Nuclear Information System (INIS)

    Weintraub, William S.

    1996-01-01

    Costs have become increasingly important in medicine in recent years as demand for services has outstripped readily available resources. Clinical microeconomics offers an approach to understanding cost and outcomes in an environment of economic scarcity. In this article the types of costs and methods for determining cost are presented. In addition, methods for assessing outcome and outcome in relation to cost are developed. Restenosis after coronary angioplasty is a prime example of a clinical problem requiring economic evaluation. This is because it results in little serious morbidity except for recurrent chest pain, but it has serious economic consequences which occur some time after the original angioplasty. This makes the economic assessment of restenosis complicated. The application of health care microeconomic principles to brachytherapy for restenosis in the coronary arteries is presented

  4. Evaluating the cost of therapy for restenosis: considerations for brachytherapy.

    Science.gov (United States)

    Weintraub, W S

    1996-11-01

    Costs have become increasingly important in medicine in recent years as demand for services has outstripped readily available resources. Clinical microeconomics offers an approach to understanding cost and outcomes in an environment of economic scarcity. In this article the types of costs and methods for determining cost are presented. In addition, methods for assessing outcome and outcome in relation to cost are developed. Restenosis after coronary angioplasty is a prime example of a clinical problem requiring economic evaluation. This is because it results in little serious morbidity except for recurrent chest pain, but it has serious economic consequences which occur some time after the original angioplasty. This makes the economic assessment of restenosis complicated. The application of health care microeconomic principles to brachytherapy for restenosis in the coronary arteries is presented.

  5. [Role of the technician in a brachytherapy department].

    Science.gov (United States)

    Bélot-Cheval, V; Lemoine, L; Cuisinier, C; Gensse, M-C; Lasbareilles, O

    2013-04-01

    The role of the technician in a brachytherapy department is essential for the cohesion of the treatment team made up of the radiation oncologist, the physicist, and the technician. He/she collaborates in the different treatment steps such as taking care of the patients, training of the professionals and research studies in collaboration with the team. He participates in all steps of the treatment such as preparation, technician's consultation, catheters/templates and radioactives sources implant, dose distribution analysis and treatment. He looks after the management of planning, radioactive sources and chemist's equipments. He takes part in the training of the junior technician, and support doctors and physicists in different studies. The procedure writing and the presentation of professional practices are also part of the technician task. Copyright © 2013 Société française de radiothérapie oncologique (SFRO). Published by Elsevier SAS. All rights reserved.

  6. Manual method for dose calculation in gynecologic brachytherapy

    International Nuclear Information System (INIS)

    Vianello, Elizabeth A.; Almeida, Carlos E. de; Biaggio, Maria F. de

    1998-01-01

    This paper describes a manual method for dose calculation in brachytherapy of gynecological tumors, which allows the calculation of the doses at any plane or point of clinical interest. This method uses basic principles of vectorial algebra and the simulating orthogonal films taken from the patient with the applicators and dummy sources in place. The results obtained with method were compared with the values calculated with the values calculated with the treatment planning system model Theraplan and the agreement was better than 5% in most cases. The critical points associated with the final accuracy of the proposed method is related to the quality of the image and the appropriate selection of the magnification factors. This method is strongly recommended to the radiation oncology centers where are no treatment planning systems available and the dose calculations are manually done. (author)

  7. Cs-137 brachytherapy sources calibration with well chamber

    International Nuclear Information System (INIS)

    Brunetto, M.; Sansogne, R.; Arbiser, S.; Duran, M.P.

    2004-01-01

    This work describes the procedures and actions developed for the identification and reference air kerma rate (S k ) verification of Cs-137 sources used in gynecological brachytherapy practices. Following the IAEA TECDOC 1151 recommendations, the first stage consisted in designing the documentation required for the inventory and shipping registry of sources, along with the digital spreadsheets for calculating the decay and S k of the sources at the moment of implantation. As a second stage, the S k of sources was measured, following the low dose rate sources protocol advise, with a Standard Imaging HDR 1000 Plus well chamber calibrated at the University of Wisconsin SSDL. The documentation generated through this procedure allows identify each source clearly and uni-vocally. No significant differences were found between the S k values obtained from the well chamber calibration procedure and those reported by the manufacturer in the corresponding certificates. The highest percent difference found was 2.3%. (author) [es

  8. Computerized planning and dosimetry for brachytherapy in carcinomas cervix

    International Nuclear Information System (INIS)

    Kizilbash, N.A.; Jabeen, K.; Hussain, R.

    1996-01-01

    A project on the use of computerize planning and dosimetry for brachytherapy in carcinoma of cervix was started at NORI (Nuclear Medicine, Oncology and Radiotherapy Institute, Islamabad) in september 1990. A total number of 182 patients were included in the study over a period of three years. The treatment of all these patients was done by external radiation as well as the intracavitary therapy. Planning and dosimetry was done according to ICRU 38 recommendations. 70 patients were planned with two computers TP-II (Dr. J. Cunningham's software) and PC based system (Dr. Kallinger's software, BTI system). From the results of the two computers TP-II and PC, it can be seen that the difference in a absorbed dose for all recommended points in not going to harm the patient. The dose to the bladder and the rectum in our studies is quite low because of the low activity in the ovoid sources. (author)

  9. Importance of the elemental composition in brachytherapy with neutrons

    International Nuclear Information System (INIS)

    Paredes G, L.; Balcazar G, M.; Azorin N, J.; Francois L, J.L.

    2004-01-01

    An analysis is presented of as the small differences that exist in the elementary composition of the wicked tumors, healthy fabrics and some material substitutes of fabric employees in dosimetry, they generate vari