WorldWideScience

Sample records for blood glucose testing

  1. Blood Test: Glucose

    Science.gov (United States)

    ... Things to Know About Zika & Pregnancy Blood Test: Glucose KidsHealth > For Parents > Blood Test: Glucose Print A A A Text Size What's in ... de sangre: glucosa What It Is A blood glucose test measures the amount of glucose (the main ...

  2. Random blood glucose testing in dental practice

    DEFF Research Database (Denmark)

    Barasch, Andrei; Safford, Monika M; Qvist, Vibeke;

    2012-01-01

    The prevalence of diabetes mellitus (DM) has been increasing. Instances of patients' not having received a diagnosis have been reported widely, as have instances of poor control of DM or prediabetes among patient's who have the disease. These facts indicate that blood glucose screening is needed....

  3. Glucose Tests

    Science.gov (United States)

    ... be limited. Home Visit Global Sites Search Help? Glucose Tests Share this page: Was this page helpful? ... the meaning of other test results. Fasting Blood Glucose Glucose Level Indication From 70 to 99 mg/ ...

  4. Hyperglycemia (High Blood Glucose)

    Medline Plus

    Full Text Available ... Blood Pressure Physical Activity High Blood Glucose My Health Advisor Tools To Know Your Risk Alert Day ... DKA (Ketoacidosis) & Ketones Kidney Disease (Nephropathy) Gastroparesis Mental Health Step On Up Treatment & Care Blood Glucose Testing ...

  5. Hyperglycemia (High Blood Glucose)

    Medline Plus

    Full Text Available ... Health Step On Up Treatment & Care Blood Glucose Testing Medication Doctors, Nurses & More Oral Health & Hygiene Women ... Living With Diabetes > Treatment and Care > Blood Glucose Testing Share: Print Page Text Size: A A A ...

  6. Hyperglycemia (High Blood Glucose)

    Medline Plus

    Full Text Available ... by Mail Close www.diabetes.org > Living With Diabetes > Treatment and Care > Blood Glucose Testing Share: Print Page Text Size: ... and-how-tos, In this section Living With Diabetes Treatment and Care Blood Glucose Testing Checking Your Blood Glucose A1C ...

  7. Hyperglycemia (High Blood Glucose)

    Medline Plus

    Full Text Available ... Nephropathy) Gastroparesis Mental Health Step On Up Treatment & Care Blood Glucose Testing Medication Doctors, Nurses & More Oral Health & Hygiene Women A1C Insulin Pregnancy ...

  8. Hyperglycemia (High Blood Glucose)

    Medline Plus

    Full Text Available ... Disease (Nephropathy) Gastroparesis Mental Health Step On Up Treatment & Care Blood Glucose Testing Medication Doctors, Nurses & More Oral Health & Hygiene Women A1C Insulin ...

  9. Monitor blood glucose - slideshow

    Science.gov (United States)

    ... medlineplus.gov/ency/presentations/100220.htm Monitoring blood glucose - Series—Monitoring blood glucose: Using a self-test meter To use the ... A.M. Editorial team. Related MedlinePlus Health Topics Blood Sugar A.D.A.M., Inc. is accredited by ...

  10. Glucose test (image)

    Science.gov (United States)

    ... person with diabetes constantly manages their blood's sugar (glucose) levels. After a blood sample is taken and tested, it is determined whether the glucose levels are low or high. If glucose levels ...

  11. Hyperglycemia (High Blood Glucose)

    Medline Plus

    Full Text Available ... Nephropathy) Gastroparesis Mental Health Step On Up Treatment & Care Blood Glucose Testing Medication Doctors, Nurses & More Oral ... 2 Diabetes Know Your Rights Employment Discrimination Health Care Professionals Law Enforcement Driver's License For Lawyers Food & ...

  12. Hyperglycemia (High Blood Glucose)

    Medline Plus

    Full Text Available ... the urine Frequent urination Increased thirst Part of managing your diabetes is checking your blood glucose often. ... Blog Online Community Site Menu Are You at Risk? Diagnosis Lower Your Risk Risk Test Alert Day ...

  13. Hyperglycemia (High Blood Glucose)

    Medline Plus

    Full Text Available ... Disease (Nephropathy) Gastroparesis Mental Health Step On Up Treatment & Care Blood Glucose Testing Medication Doctors, Nurses & More ... us get closer to curing diabetes and better treatments for those living with diabetes. Other Ways to ...

  14. Low Blood Glucose (Hypoglycemia)

    Science.gov (United States)

    ... Other Dental Problems Diabetic Eye Disease Low Blood Glucose (Hypoglycemia) What is hypoglycemia? Hypoglycemia, also called low ... actions can also help prevent hypoglycemia: Check blood glucose levels Knowing your blood glucose level can help ...

  15. Internet-Based Contingency Management to Improve Adherence with Blood Glucose Testing Recommendations for Teens with Type 1 Diabetes

    Science.gov (United States)

    Raiff, Bethany R.; Dallery, Jesse

    2010-01-01

    The current study used Internet-based contingency management (CM) to increase adherence with blood glucose testing to at least 4 times daily. Four teens diagnosed with Type 1 diabetes earned vouchers for submitting blood glucose testing videos over a Web site. Participants submitted a mean of 1.7 and 3.1 blood glucose tests per day during the 2…

  16. Impact of Epidemic Rates of Diabetes on the Chinese Blood Glucose Testing Market

    OpenAIRE

    Hu, Jamie; Zhang, Xian-En

    2011-01-01

    China has become the country with the largest diabetes mellitus population in the world since the 1990s. About 100 million diabetes cases have been diagnosed since 2008. Handheld blood glucose meters and test strips are urgently needed for daily patient measurement. The glucose monitor with a screen-printed carbon-based glucose electrode has been in commercial production since 1994. Since then, approximately 20 companies have been involved in manufacturing and marketing meters and test strips...

  17. Hyperglycemia (High Blood Glucose)

    Medline Plus

    Full Text Available ... symptoms include the following: High blood glucose High levels of sugar in the urine Frequent urination Increased ... you should check and what your blood glucose levels should be. Checking your blood and then treating ...

  18. Hyperglycemia (High Blood Glucose)

    Medline Plus

    Full Text Available ... how often you should check and what your blood glucose levels should be. Checking your blood and then treating ... I Treat Hyperglycemia? You can often lower your blood glucose level by exercising. However, if your blood glucose is ...

  19. Hyperglycemia (High Blood Glucose)

    Medline Plus

    Full Text Available ... and eAG Hypoglycemia (Low blood glucose) Hyperglycemia (High blood glucose) Dawn Phenomenon Checking for Ketones Tight Diabetes Control donate en -- Diabetes Must Be Stopped - 2016-06-donation- ...

  20. Impact of epidemic rates of diabetes on the Chinese blood glucose testing market.

    Science.gov (United States)

    Hu, Jamie; Zhang, Xian-En

    2011-09-01

    China has become the country with the largest diabetes mellitus population in the world since the 1990s. About 100 million diabetes cases have been diagnosed since 2008. Handheld blood glucose meters and test strips are urgently needed for daily patient measurement. The glucose monitor with a screen-printed carbon-based glucose electrode has been in commercial production since 1994. Since then, approximately 20 companies have been involved in manufacturing and marketing meters and test strips in China. The current market and production volume and updates on technology issues are discussed in this article. PMID:22027332

  1. CSF glucose test

    Science.gov (United States)

    Glucose test - CSF; Cerebrospinal fluid glucose test ... The glucose level in the CSF should be 50 to 80 mg/100 mL (or greater than 2/3 of the blood sugar level). Note: Normal value ranges may vary slightly ...

  2. Disposable glucose test strip for whole blood with integrated sensing/diffusion-limiting layer

    Energy Technology Data Exchange (ETDEWEB)

    Chen Zhencheng [Department of Biomedical Engineering, School of Info-Physics and Geomatics Engineering, Central South University, Changsha 410083 (China); Fang Cheng, E-mail: fangpingchuan@163.co [Department of Biomedical Engineering, School of Info-Physics and Geomatics Engineering, Central South University, Changsha 410083 (China); Wang Hongyan; He Jishan [Department of Biomedical Engineering, School of Info-Physics and Geomatics Engineering, Central South University, Changsha 410083 (China)

    2009-12-30

    A disposable glucose test strip with an integrated sensing/diffusion-limiting layer was developed. A formulation containing filler, glucose oxidase and electronic mediator was screen-printed over two carbon electrodes to form an integrated sensing/diffusion-limiting layer. On rehydration, the integrated layer does not break up, but swells to form a gelled and three-dimensional meshy reaction zone on the surface of the underlying conductive elements in which reactants and mediator move freely, but interfering species such as red blood cells containing oxygenated hemoglobin are excluded. On the same time, the integrated layer maintains a rate of permeation of the analyte through it with a variation of less than 10% at temperatures ranging from 15 deg. C to 42 deg. C. This biosensor is substantially insensitive to interferents and essentially independent to relevant temperature, which provides a more reliable reading of actual blood glucose value in human whole blood.

  3. Hyperglycemia (High Blood Glucose)

    Medline Plus

    Full Text Available ... Risk Healthy Eating Overweight Smoking High Blood Pressure Physical Activity High Blood Glucose My Health Advisor Tools To ... Index Low-Calorie Sweeteners Sugar and Desserts Fitness Exercise & Type 1 Diabetes Get Started Safely Get And ...

  4. Hyperglycemia (High Blood Glucose)

    Medline Plus

    Full Text Available ... Overweight Smoking High Blood Pressure Physical Activity High Blood Glucose My Health Advisor Tools To Know Your Risk Alert Day Diabetes Basics Home Symptoms Diagnosis America's Diabetes Challenge Type 1 Type 2 Facts About Type 2 Enroll ...

  5. Glucose tolerance test - non-pregnant

    Science.gov (United States)

    Oral glucose tolerance test - non-pregnant; OGTT - non-pregnant; Diabetes - glucose tolerance test ... The most common glucose tolerance test is the oral glucose tolerance test (OGTT). Before the test begins, a sample of blood will be ...

  6. INTERNET-BASED CONTINGENCY MANAGEMENT TO IMPROVE ADHERENCE WITH BLOOD GLUCOSE TESTING RECOMMENDATIONS FOR TEENS WITH TYPE 1 DIABETES

    OpenAIRE

    Raiff, Bethany R.; Dallery, Jesse

    2010-01-01

    The current study used Internet-based contingency management (CM) to increase adherence with blood glucose testing to at least 4 times daily. Four teens diagnosed with Type 1 diabetes earned vouchers for submitting blood glucose testing videos over a Web site. Participants submitted a mean of 1.7 and 3.1 blood glucose tests per day during the 2 baseline conditions, respectively, compared to 5.7 tests per day during the intervention. Participants and their guardians rated the program favorably...

  7. Fingertip Blood Capillary Whole Blood Glucose and Venous Plasma Glucose test Results Contrast Analysis%指尖毛细血管全血糖与静脉血浆血糖检测结果对比分析

    Institute of Scientific and Technical Information of China (English)

    邢美荣

    2016-01-01

    Objective To compare the blood glucose and blood glucose in the blood glucose and blood glucose of the finger tip blood glucose and to explore the accuracy of blood glucose detection in the blood glucose of finger tip capillary. Meth-ods From January 2014 to October 2015, 200 cases of blood glucose detection in the center of the disease control depart-ment of our CDC were studied. According to their blood glucose levels, the patients were divided into low blood sugar group, normal group, abnormal glucose tolerance group and diabetic group. Blood glucose was detected by using the automatic bio-chemical analyzer to measure blood glucose of blood and blood glucose in the blood and blood of the finger tip, which were collected from 200 cases of the patients. Results There were no significant differences in blood glucose levels between the blood glucose test results of the blood glucose test of the blood glucose and the blood glucose in the blood glucose of the patients with low blood glucose, glucose tolerance and glucose tolerance test in the patients with low blood glucose and glu-cose tolerance. Conclusion The method of blood glucose detection in blood glucose of finger tip has a high accuracy, and it is close to that of venous blood glucose detection. It can effectively reflect the blood glucose level of the subjects, and can be used as an effective method for the monitoring and management of the community and family.%目的:对比分析指尖毛细血管全血血糖与静脉血浆血糖的检测结果,以探讨指尖毛细血管全血糖检测血糖的准确性。方法于2014年1月-2015年10月,选取在该疾控中心体检科进行血糖检测的200例受检者进行研究,按照其血糖情况进行分组,分为低血糖组、血糖正常组、糖耐量异常组、糖尿病组。分别于空腹状态时和餐后2 h,采集这200例受检者的指尖毛细血管全血和外周静脉血液,使用全自动生化分析仪进行血糖测定,对比指尖毛细血

  8. Hyperglycemia (High Blood Glucose)

    Medline Plus

    Full Text Available ... avoid problems associated with hyperglycemia. How Do I Treat Hyperglycemia? You can often lower your blood glucose ... be a serious problem if you don't treat it, so it's important to treat as soon ...

  9. Hyperglycemia (High Blood Glucose)

    Medline Plus

    Full Text Available ... Complications DKA (Ketoacidosis) & Ketones Kidney Disease (Nephropathy) Gastroparesis Mental Health Step On Up Treatment & Care Blood Glucose ... Find Your Local Office Find your local diabetes education program Calendar of Events Wellness Lives Here Drive ...

  10. Hyperglycemia (High Blood Glucose)

    Science.gov (United States)

    ... Text Size: A A A Listen En Español Hyperglycemia (High Blood Glucose) Hyperglycemia is the technical term ... body can't use insulin properly. What Causes Hyperglycemia? A number of things can cause hyperglycemia: If ...

  11. Hyperglycemia (High Blood Glucose)

    Medline Plus

    Full Text Available ... Hispanic Heritage Month African American Programs Latino Programs Asian Americans, Native Hawaiians and Pacific Islanders American Indian/ ... High blood glucose happens when the body has too little insulin or when the body can't ...

  12. USING CAPILLARY WHOLE BLOOD GLUCOSE TEST IN SCREENING FOR GESTATIONAL DIABETES MELLITUS

    Institute of Scientific and Technical Information of China (English)

    WU Qing-kai; LUO Lai-min; GU Jing-hong; LI Ping; HUANG Ya-juan; FENG Jie; ZHANG Rui

    2007-01-01

    Objective To discuss whether the capillary whole blood glucose (CBG) test can be used in glucose screening test (GST) for gestational diabetes mellitus (GDM) compared to the venous plasma glucose (VPG) method, and to determine the cutoff value of CBG. Methods This was a self-control test. The 50-g oral GST was conducted among 1 557 pregnant women between 24-28 weeks. Every woman was measured CBG and VPG at the same time and same arm. Three hundred and forty women underwent 100-g 3-h oral glucose tolerance test (OGTT). Receiver operation curve (ROC) was used to determine the potential cutoff level of CBG and VPG. Diagnose criteria of GDM was based on NDDG criteria. OGTT diagnosed GDM and VPG ≥ 7. 8 mmol/L were used as golden standard for ROC. Results There was good relationship between CBG and VPG ( P < 0.01 ). Correlation coefficient was 0. 86. The value of CBG was lower than VPG. The statistical and high-sensitivity cutoff values were 7. 4 mmol/L in CBG and 7. 8 mmol/L in VPG when GDM was used as golden standard. Cutoff value of CBG was 7. 0 mmol/L when VPG≥ 7. 8 mmol/L was used as golden standard. The pregnant outcomes of positive cases of three thresholds had no significant differences. But it was better in case of the pregnant woman when the CBG value was more than 7. 4 mmol/L. Conclusion CBG can be used in GST, the threshold of CBG was suggested as 7. 4 mmol/L. CBG test was more convenience and effective than VPG test.

  13. Improving Detection of Prediabetes in Children and Adults: Using Combinations of Blood Glucose Tests

    Directory of Open Access Journals (Sweden)

    Ike Solomon Okosun

    2015-11-01

    Full Text Available Aim: To determine combinations of blood glucose tests: oral glucose tolerance (OGT, fasting plasma glucose (FBG and hemoglobin A1C (HbA1C that are associated with highest diagnostic rates of prediabetes in non-diabetic American children and adults.Methods: The 2007-2008 U.S. National Health and Nutrition Examination Surveys data were used for this study. Overall and specific prevalence of prediabetes (defined using OGT+FPG, OGT+HbA1C, HbA1C+FPG and OGT+FPG+HbA1C tests were determined across age, race/ethnicity, sex and BMI categories.Results: FPG+HbA1C test was associated with significantly higher diagnostic rates of prediabetes across age, race/ethnicity and BMI. Estimates of overall prevalence of prediabetes using OGT+FPG, OGT+HbA1C, HbA1C+FPG and OGT+FPG+HbA1C tests were 20.3%, 24.2%, 33% and 34.3%, respectively. Compared to OGT+FPG, the use of HbA1C+FPG test in screening was associated with 44.8%, 135%, 38.6% and 35.9% increased prevalence of prediabetes in non-Hispanic White, non-Hispanic Black, Mexican-American and other racial/ethnic men, respectively. The corresponding values in women were 67.8%, 140%, 37.2% and 42.6%, respectively. Combined use of all blood glucose tests did not improve the overall and gender-specific prediabetes prevalence beyond what was observed using HbA1C+FPG test.Conclusions: HbA1C criteria were associated with higher diagnosis rates of prediabetes than FPG and OGT tests in non-diabetic American children and adults. Using a combination of HbA1C and FPG test in screening for prediabetes reduces intrinsic systematic bias in using just HbA1C testing and offers the benefits of each test. A well-defined HbA1C that takes into consideration race/ethnicity, gender, age and body mass index may improve detection of prediabetes in population and clinical settings.

  14. Hyperglycemia (High Blood Glucose)

    Medline Plus

    Full Text Available ... In Memory In Honor Become a Member En Español Type 1 Type 2 About Us Online Community ... Page Text Size: A A A Listen En Español Hyperglycemia (High Blood Glucose) Hyperglycemia is the technical ...

  15. Hyperglycemia (High Blood Glucose)

    Medline Plus

    Full Text Available ... Size: A A A Listen En Español Hyperglycemia (High Blood Glucose) Hyperglycemia is the technical term for ... diabetes. Learn More: Stories of Courage, Love and Resilience - 2016-08-blog.html Learn More Stories of ...

  16. The impact of high-dose vitamin C on blood glucose testing in ¹⁸F-FDG PET imaging.

    Science.gov (United States)

    Bahr, Rebekah L; Wilson, Don C

    2015-03-01

    Complementary and alternative therapies in addition to standard oncology protocols are commonly sought by cancer patients; however, few patients disclose their complementary treatments to their cancer care team. A lack of communication may result in unforeseen side effects and the potential for some alternative therapies to interfere with or inhibit conventional treatment. High-dose vitamin C therapy, in particular, may lead to an inability to measure a patient's blood glucose level before (18)F-FDG injection for PET/CT scanning. We report a case of a 52-y-old woman referred for (18)F-FDG PET/CT to evaluate the extent of recurrent colorectal cancer. The PET/CT scan immediately followed a single intravenous dose of 25 g of ascorbic acid from her naturopath. A glucometer that applies the glucose oxidase method for measuring fasting blood glucose was used, for which high doses of vitamin C are listed as a contraindication. The high concentration of ascorbic acid in the patient's blood sample interfered with the chemical reaction on the glucose strip, and therefore no blood glucose measurement could be attained. With more patients receiving alternative and complementary cancer therapies, it is important to know what the implications of orthomolecular therapy might be on routine blood glucose testing for (18)F-FDG PET scans. (18)F-FDG is in direct competition with glucose; therefore, elevated blood glucose levels will cause a decrease in (18)F-FDG absorption and may lead to a false-negative scan. PMID:25104819

  17. Breakfast, blood glucose, and cognition.

    Science.gov (United States)

    Benton, D; Parker, P Y

    1998-04-01

    This article compares the findings of three studies that explored the role of increased blood glucose in improving memory function for subjects who ate breakfast. An initial improvement in memory function for these subjects was found to correlate with blood glucose concentrations. In subsequent studies, morning fasting was found to adversely affect the ability to recall a word list and a story read aloud, as well as recall items while counting backwards. Failure to eat breakfast did not affect performance on an intelligence test. It was concluded that breakfast consumption preferentially influences tasks requiring aspects of memory. In the case of both word list recall and memory while counting backwards, the decline in performance associated with not eating breakfast was reversed by the consumption of a glucose-supplemented drink. Although a morning fast also affected the ability to recall a story read aloud, the glucose drink did not reverse this decline. It appears that breakfast consumption influences cognition via several mechanisms, including an increase in blood glucose. PMID:9537627

  18. Factors Affecting Initial Training Success of Blood Glucose Testing in Captive Chimpanzees (Pan troglodytes)

    Science.gov (United States)

    Reamer, Lisa A.; Haller, Rachel L.; Thiele, Erica J.; Freeman, Hani D.; Lambeth, Susan P.; Schapiro, Steven J.

    2016-01-01

    Type 2 diabetes can be a problem for captive chimpanzees. Accurate blood glucose (BG) readings are necessary to monitor and treat this disease. Thus, obtaining voluntary samples from primates through positive reinforcement training (PRT) is critical. The current study assessed the voluntary participation of 123 chimpanzees in BG sampling and investigated factors that may contribute to individual success. All subjects participate in regular PRT sessions as part of a comprehensive behavioral management program. Basic steps involved in obtaining BG values include: voluntarily presenting a finger/toe; allowing digit disinfection; holding for the lancet device; and allowing blood collection onto a glucometer test strip for analysis. We recorded the level of participation (none, partial, or complete) when each chimpanzee was first asked to perform the testing procedure. Nearly 30% of subjects allowed the entire procedure in one session, without any prior specific training for the target behavior. Factors that affected this initial successful BG testing included sex, personality (chimpanzees rated higher on the factor “openness” were more likely to participate with BG testing), and past training performance for “present-for-injection” (chimpanzees that presented for their most recent anesthetic injection were more likely to participate). Neither age, rearing history, time since most recent anesthetic event nor social group size significantly affected initial training success. These results have important implications for captive management and training program success, underlining individual differences in training aptitude and the need for developing individual management plans in order to provide optimal care and treatment for diabetic chimpanzees in captivity. PMID:24706518

  19. Hyperglycemia (High Blood Glucose)

    Medline Plus

    Full Text Available ... Type 2 Diabetes Risk Test Lower Your Risk Healthy Eating Overweight Smoking High Blood Pressure Physical Activity High ... the Guesswork out of Planning Meals! Find the healthy eating plan that works for you and your diabetes. ...

  20. Hyperglycemia (High Blood Glucose)

    Medline Plus

    Full Text Available ... 2 Diabetes Risk Test Lower Your Risk Healthy Eating Overweight Smoking High Blood Pressure Physical Activity High ... What Can I Drink? Fruit Dairy Food Tips Eating Out Quick Meal Ideas Snacks Nutrient Content Claims ...

  1. Blood glucose testing and primary prevention of diabetes mellitus type 2 - evaluation of the effect of evidence based patient information

    Directory of Open Access Journals (Sweden)

    Giani Guido

    2010-01-01

    Full Text Available Abstract Background Evidence-based patient information (EBPI has been recognised as important tool for informed choice in particular in the matter of preventive options. An objective, on the best scientific evidence-based consumer information about subthreshold elevated blood glucose levels (impaired fasting glucose and impaired glucose tolerance and primary prevention of diabetes, is not available yet. Thus we developed a web-based EBPI and aim to evaluate its effects on informed decision making in people 50 years or older. Methods/Design We conduct a web-based randomised-controlled trial to evaluate the effect of information about elevated blood glucose levels and diabetes primary prevention on five specific outcomes: (i knowledge of elevated blood glucose level-related issues (primary outcome; (ii attitudes to a metabolic testing; (iii intention to undergo a metabolic testing; (iv decision conflict; (v satisfaction with the information. The intervention group receives a specially developed EBPI about subthreshold elevated blood glucose levels and diabetes primary prevention, the control group information about this topic, available in the internet. The study population consists of people between 50 and 69 years of age without known diabetes. Participants will be recruited via the internet page of the cooperating health insurance company, Techniker Krankenkasse (TK, and the internet page of the German Diabetes Centre. Outcomes will be measured through online questionnaires. We expect better informed participants in the intervention group. Discussion The design of this study may be a prototype for other web-based prevention information and their evaluation. Trial registration Current Controlled Trial: ISRCTN22060616.

  2. Hyperglycemia (High Blood Glucose)

    Medline Plus

    Full Text Available ... Doctors, Nurses & More Oral Health & Hygiene Women A1C Insulin Pregnancy 8 Tips for Caregivers Health Insurance Health ... glucose happens when the body has too little insulin or when the body can't use insulin ...

  3. Blood Glucose Monitoring Devices

    Science.gov (United States)

    ... Glucose NIH Medline Plus - Diabetes Spotlight FDA permits marketing of first system of mobile medical apps for ... feeds Follow FDA on Twitter Follow FDA on Facebook View FDA videos on YouTube View FDA photos ...

  4. Hyperglycemia (High Blood Glucose)

    Medline Plus

    Full Text Available ... critical diabetes research and support vital diabetes education services that improve the lives of those with diabetes. $ ... glucose level. Cutting down on the amount of food you eat might also help. Work with your ...

  5. Blood glucose in acute stroke

    DEFF Research Database (Denmark)

    Olsen, Tom Skyhøj

    2009-01-01

    Blood glucose is often elevated in acute stroke, and higher admission glucose levels are associated with larger lesions, greater mortality and poorer functional outcome. In patients treated with thrombolysis, hyperglycemia is associated with an increased risk of hemorrhagic transformation...... of infarcts. For a number of years, tight glycemic control has been regarded as beneficial in critically illness, but recent research has been unable to support this notion. The only completed randomized study on glucose-lowering therapy in stroke has failed to demonstrate effect, and concerns relating...... to the risk of inducing potentially harmful hypoglycemia has been raised. Still, basic and observational research is overwhelmingly in support of a causal relationship between blood glucose and stroke outcome and further research on glucose-lowering therapy in acute stroke is highly warranted....

  6. Dietary thylakoids suppress blood glucose and modulate appetite-regulating hormones in pigs exposed to oral glucose tolerance test

    DEFF Research Database (Denmark)

    Montelius, Caroline; Szwiec, Katarzyna; Kardas, Marek;

    2014-01-01

    BACKGROUND & AIMS: Dietary chloroplast thylakoids have previously been found to reduce food intake and body weight in animal models, and to change metabolic profiles in humans in mixed-food meal studies. The aim of this study was to investigate the modulatory effects of thylakoids on glucose meta...

  7. Is Low Blood Glucose (Hypoglycemia) Dangerous?

    Science.gov (United States)

    ... Diabetes Sign Up forJoslin Newsletters Is Low Blood Glucose (Hypoglycemia) Dangerous? Low blood glucose or hypoglycemia is one of the most common ... In general, hypoglycemia is defined as a blood glucose level below 70 mg/dl. Low blood glucose ...

  8. Hyperglycemia (High Blood Glucose)

    Medline Plus

    Full Text Available ... you avoid problems associated with hyperglycemia. How Do I Treat Hyperglycemia? You can often lower your blood ... record for use in an emergency. How Can I Prevent Hyperglycemia? Your best bet is to practice ...

  9. Hyperglycemia (High Blood Glucose)

    Medline Plus

    Full Text Available ... Student Resources History of Diabetes Resources for School Projects How to Reference Our Site Diabetes Basics Myths ... blood, which can lead to ketoacidosis. Ketoacidosis is life-threatening and needs immediate treatment. Symptoms include: Shortness ...

  10. Hyperglycemia (High Blood Glucose)

    Medline Plus

    Full Text Available ... and-a1c-hyperglycemia,tips-and-how-tos, In this section Living With Diabetes Treatment and Care Blood ... ensureArray(data.submitSurveyResponse.errors); $.each(surveyErrors, function () { if (this.errorField) { $('input[name="' + this.errorField + '"]').closest('.form-group') . ...

  11. Hyperglycemia (High Blood Glucose)

    Medline Plus

    Full Text Available ... and Learning About Prediabetes Type 2 Diabetes Risk Test Lower Your Risk Healthy Eating Overweight Smoking High ... prediabetes, and no one is excused. Take the test. Know where you stand. sticky en -- Chef Ronaldo's ...

  12. Hyperglycemia (High Blood Glucose)

    Medline Plus

    Full Text Available ... and Learning About Prediabetes Type 2 Diabetes Risk Test Lower Your Risk Healthy Eating Overweight Smoking High ... prediabetes, and no one is excused. Take the test. Know where you stand. sticky en -- The Italian ...

  13. Hyperglycemia (High Blood Glucose)

    Medline Plus

    Full Text Available ... and Learning About Prediabetes Type 2 Diabetes Risk Test Lower Your Risk Healthy Eating Overweight Smoking High ... You at Risk? Diagnosis Lower Your Risk Risk Test Alert Day Prediabetes My Health Advisor Tools to ...

  14. Hyperglycemia (High Blood Glucose)

    Medline Plus

    Full Text Available ... You at Risk? Home Prevention Diagnosing Diabetes and Learning About Prediabetes Type 2 Diabetes Risk Test Lower ... Volunteer Opportunities Sponsorship and Exhibit Opportunities Diabetes Camp Learning at Camp Find a Camp Apply for Camp ...

  15. Hyperglycemia (High Blood Glucose)

    Medline Plus

    Full Text Available ... Your Plate Gluten Free Diets Meal Planning for Vegetarian Diets Cook with Heart-Healthy Foods Holiday Meal ... Blog Online Community Site Menu Are You at Risk? Diagnosis Lower Your Risk Risk Test Alert Day ...

  16. Comparative performance of lab tests and blood testing device to monitor glucose, total cholesterol and triacylglycerol in type 2 diabetic patients

    Directory of Open Access Journals (Sweden)

    Arnaldo Zubioli

    2011-09-01

    Full Text Available The performance of lab tests (LT and blood testing devices (BTD to monitor glycemia vs. glycated hemoglobin A1c (A1c were compared. In addition, the performance of blood glucose, total cholesterol (TC and triacylglycerol measured by LT and BDT were compared. All parameters were measured based on the same blood samples from overnight fasted type 2 diabetic patients (T2DP. Linear regression analysis was used for all comparisons. The results showed that A1c correlated better with LT-glucose (r = 0.58 than BTD-glucose (r = 0.42. Moreover, LT vs. BTD showed r values of 0.90, 0.82 and 0.92 for glucose, TC and triacylglycerol, respectively. It was concluded that the performance of LT-glucose was better than BDT-glucose. Moreover, since triacylycerol and TC measured by BTD correlated better with LT compared to BDT-glucose vs. LT-glucose, the inclusion of BTD-TC and BTD-triacylglycerol for detecting and monitoring hyperlipidemia in T2DP should be considered.Comparou-se a performance de avaliação da glicemia através de dosagens laboratoriais (DL ou dispositivo para teste de sangue capilar (DTSC vs. hemoglobina glicada A1c (A1c. Comparou-se ainda a performance de avaliação da glicemia, colesterol total (CT e triacilglicerol (DL vs. DTSC. Avaliou-se estes parametros a partir das mesmas amostras de sangue coletadas em pacientes diabéticos tipo 2 (PDT2 em jejum noturno, sendo as comparações realizadas através de análise de regressão linear. A A1c correlacionou-se melhor com a glicemia-DL (r = 0,58 em relação a glicemia-DTSC (r = 0,42. Comparou-se DL vs. DTSC obtendo se r = 0,90, 0,82 e 0,92 para glicemia, CT e triacilglicerol, respectivamente. Concluiu-se que houve melhor performance da glicose-DL em relação a glicose-DTSC. Além disso, considerando que o triacilglicerol e TC avaliado através de DTSC correlaciona-se melhor com DL em comparação a DTSC-glicose vs. DL-glicose, a inclusão de DTSC-TC e DTSC-triacilglicerol visando detectar e

  17. Reduction of the interferences of biochemicals and hematocrit ratio on the determination of whole blood glucose using multiple screen-printed carbon electrode test strips.

    Science.gov (United States)

    Lin, Yueh-Hui; Shen, Thomas Y; Chang, C Allen

    2007-11-01

    A practical approach to reduce the interferences of biochemicals and hematocrit ratio (Hct%) in the determination of whole blood glucose using multiple screen-printed carbon electrode (SPCE) test strips is described. SPCE test strips with and without glucose oxidase [i.e., GOD(+)-SPCEs and GOD(-)-SPCEs] were used and the chronoamperometric currents of test glucose solutions with various spiked uric acid concentrations and Hct% were measured. By establishing the interference relationships between glucose concentrations and uric acid concentrations as well as Hct% values and with appropriate corrections, the whole blood glucose determinations could be made to be more accurate and comparable to those determined by the reference YSI method. Specifically, the use of the DeltaI value, i.e., the current difference between GOD(+)-SPCE and GOD(-)-SPCE measurements, would reduce most of the uric acid/biochemical interferences. An interpolation method was also established to correct for the glucose determinations with Hct% interferences. The Hct% corrections using the interpolation method are especially important and necessary for those blood samples with glucose concentrations higher than 110 mg dL(-1) and Hct% values lower than 35%. This approach should also be applicable to other biochemical determinations using similar electrochemical techniques. PMID:17912503

  18. Postprandial blood glucose latency after oatmeal is a valid screening test for diabetic gastropathy in type 1 diabetes, but not in type 2 diabetes.

    Science.gov (United States)

    Jüngling, B; Schleiffer, T; Buttmann, A; Kraatz, K; Kress, S; Vogt, M; Windeler, J; Riemann, J F

    2001-04-01

    Disordered gastric motility occurs frequently in diabetes mellitus. Gastric emptying time is abnormal in about 50% of diabetic patients and delayed emptying time is known as an important cause for brittle diabetes in type 1 diabetes. We compared the rise in blood glucose after a standardized meal (oatmeal test) as a noninvasive screening test for diabetic gastropathy with the noninvasive measurement of gastric emptying time with ultrasound in type 1 and type 2 diabetic patients. The test result was considered pathological if the rise of blood glucose after an initial steady state did not reach 20 mg/dl in the first 20 min after the meal (prolonged blood glucose latency). We found a sensitivity of 90% (58.7-99.8) and a specificity of 100% (71.5-100) for the oatmeal test in type 1 diabetes in the gastropathy screening. In type 2 diabetes we found a sensitivity of 13% (1.5-38.3) and a specificity of 78% (60-90.7) (95% CI). In conclusion, the oatmeal test seemed to be a good, noninvasive screening test in diabetic gastropathy in type 1 diabetes, but has no diagnostic value in type 2 diabetes. The causes for such a difference may be due to a different postprandial blood glucose regulation in type 2 diabetes compared to the beta-cell-depleted type 1 diabetes.

  19. Recent developments in blood glucose sensors

    Directory of Open Access Journals (Sweden)

    Hui-Chen Wang

    2015-06-01

    Full Text Available Diabetes has recently become a leading cause of death worldwide. To date, although there is no means to cure or prevent diabetes, appropriate medication and blood sugar monitoring can enhance treatment efficiency, alleviate the symptoms, and diminish the complications of the condition. This review article deals with current growth areas in the market for blood glucose sensors and possible future alternatives, which are generally considered to be the point sample test and the continuous glucose monitor (CGM. Most glucose sensors are enzyme-based, whereas others are enzyme-free. The former class is sensitive and some products are extensively employed for daily self-sensing and in hospital environments as reliable diagnostic tools. The latter class, particularly the boronic acid fluorescent sensor, is facile and extremely promising. Practicality demands that all types of sensors offer accuracy, specificity, and real-time detection.

  20. 21 CFR 862.1345 - Glucose test system.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Glucose test system. 862.1345 Section 862.1345....1345 Glucose test system. (a) Identification. A glucose test system is a device intended to measure glucose quantitatively in blood and other body fluids. Glucose measurements are used in the diagnosis...

  1. Nutritional status and random blood glucose, cholesterol and triglyceride test among Malaysian Army (MA) personnel in Kuala Lumpur

    Energy Technology Data Exchange (ETDEWEB)

    Nadiy, I.; Razalee, S.; Zalifah, M. K. [Nutrition Programme, School of Chemical Sciences and Food Technology, Faculty of Science and Technology, Universiti Kebangsaan Malaysia,43600, Selangor (Malaysia); Zulkeffeli, M. J. [Department of Health Service, Ministry of Defense, Level 11, Menara Park, 50450 (Malaysia)

    2013-11-27

    With the rising trend of obesity among the general population, it is also important to assess the obesity and health status among military population. The aim of this study was to determine the prevalence of overweight and obesity among Malaysian Army (MA) personnel as well as the relationship between selected socio-demographics factors, antropometric profiles, body composition and random blood test value. A cross sectional study involving 378 male military personnel aged between 20 to 48 years old was conducted at two MA bases in Kuala Lumpur between November and December 2012. Antropometric measurements included height, weight and waist circumference (WC). Body fat percentage was measured using bioelectrical impedance analysis method (Tanita TBF-300A). Mean height, weight, BMI, WC, body fat percentage, age, monthly income and duration of service were 1.71 ± 0.6 m, 71.7 ± 12.2 kg, 24.6 ± 4.1 kg/m{sup 2}, 87.0 ± 10.0 cm, 23.4 ± 6.6%, 29.1 ± 5.5 years, RM 2115.12 ± 860.70 and 9.9 ± 5.6 years respectively. According to WHO (1998) classification of BMI, 3.2% of the subjects were underweight, 54.8% normal, 32.8% overweight and 9.3% obese. It was obeserved that 40.2% of the subjects had waist circumference value of 90 cm or more and were considered high risk for diebetes and cardiovascular diseases. This study found that BMI was highly correlated with weight (r=0.925, p<0.05), WC (r=0.852, p<0.05) and body fat percentage. Body fat percentage also show high correlation with weight (r=0.759, p<0.05) and WC (r=0.768, p<0.05. The result from 173 of 378 subjects that were selected for random blood test found that 4.6%, 3.5% and 26.0% had diabetes, high cholesterol and high triglyceride respectively. There was a weak correlation between random blood glucose level with weight (r=0.221, p<0.05), BMI (r=0.243, p<0.05), WC (r=0.298, p<0.05), body fat percentage (r=0.163, p<0.05) and age (r=0.223, p<0.05). Random blood cholesterol level had significant correlation with

  2. Nutritional status and random blood glucose, cholesterol and triglyceride test among Malaysian Army (MA) personnel in Kuala Lumpur

    International Nuclear Information System (INIS)

    With the rising trend of obesity among the general population, it is also important to assess the obesity and health status among military population. The aim of this study was to determine the prevalence of overweight and obesity among Malaysian Army (MA) personnel as well as the relationship between selected socio-demographics factors, antropometric profiles, body composition and random blood test value. A cross sectional study involving 378 male military personnel aged between 20 to 48 years old was conducted at two MA bases in Kuala Lumpur between November and December 2012. Antropometric measurements included height, weight and waist circumference (WC). Body fat percentage was measured using bioelectrical impedance analysis method (Tanita TBF-300A). Mean height, weight, BMI, WC, body fat percentage, age, monthly income and duration of service were 1.71 ± 0.6 m, 71.7 ± 12.2 kg, 24.6 ± 4.1 kg/m2, 87.0 ± 10.0 cm, 23.4 ± 6.6%, 29.1 ± 5.5 years, RM 2115.12 ± 860.70 and 9.9 ± 5.6 years respectively. According to WHO (1998) classification of BMI, 3.2% of the subjects were underweight, 54.8% normal, 32.8% overweight and 9.3% obese. It was obeserved that 40.2% of the subjects had waist circumference value of 90 cm or more and were considered high risk for diebetes and cardiovascular diseases. This study found that BMI was highly correlated with weight (r=0.925, p<0.05), WC (r=0.852, p<0.05) and body fat percentage. Body fat percentage also show high correlation with weight (r=0.759, p<0.05) and WC (r=0.768, p<0.05. The result from 173 of 378 subjects that were selected for random blood test found that 4.6%, 3.5% and 26.0% had diabetes, high cholesterol and high triglyceride respectively. There was a weak correlation between random blood glucose level with weight (r=0.221, p<0.05), BMI (r=0.243, p<0.05), WC (r=0.298, p<0.05), body fat percentage (r=0.163, p<0.05) and age (r=0.223, p<0.05). Random blood cholesterol level had significant correlation with weight (r

  3. Nutritional status and random blood glucose, cholesterol and triglyceride test among Malaysian Army (MA) personnel in Kuala Lumpur

    Science.gov (United States)

    Nadiy, I.; Razalee, S.; Zalifah, M. K.; Zulkeffeli, M. J.

    2013-11-01

    With the rising trend of obesity among the general population, it is also important to assess the obesity and health status among military population. The aim of this study was to determine the prevalence of overweight and obesity among Malaysian Army (MA) personnel as well as the relationship between selected socio-demographics factors, antropometric profiles, body composition and random blood test value. A cross sectional study involving 378 male military personnel aged between 20 to 48 years old was conducted at two MA bases in Kuala Lumpur between November and December 2012. Antropometric measurements included height, weight and waist circumference (WC). Body fat percentage was measured using bioelectrical impedance analysis method (Tanita TBF-300A). Mean height, weight, BMI, WC, body fat percentage, age, monthly income and duration of service were 1.71 ± 0.6 m, 71.7 ± 12.2 kg, 24.6 ± 4.1 kg/m2, 87.0 ± 10.0 cm, 23.4 ± 6.6%, 29.1 ± 5.5 years, RM 2115.12 ± 860.70 and 9.9 ± 5.6 years respectively. According to WHO (1998) classification of BMI, 3.2% of the subjects were underweight, 54.8% normal, 32.8% overweight and 9.3% obese. It was obeserved that 40.2% of the subjects had waist circumference value of 90 cm or more and were considered high risk for diebetes and cardiovascular diseases. This study found that BMI was highly correlated with weight (r=0.925, p<0.05), WC (r=0.852, p<0.05) and body fat percentage. Body fat percentage also show high correlation with weight (r=0.759, p<0.05) and WC (r=0.768, p<0.05. The result from 173 of 378 subjects that were selected for random blood test found that 4.6%, 3.5% and 26.0% had diabetes, high cholesterol and high triglyceride respectively. There was a weak correlation between random blood glucose level with weight (r=0.221, p<0.05), BMI (r=0.243, p<0.05), WC (r=0.298, p<0.05), body fat percentage (r=0.163, p<0.05) and age (r=0.223, p<0.05). Random blood cholesterol level had significant correlation with weight (r

  4. Accuracy of handheld blood glucose meters at high altitude.

    Directory of Open Access Journals (Sweden)

    Pieter de Mol

    Full Text Available BACKGROUND: Due to increasing numbers of people with diabetes taking part in extreme sports (e.g., high-altitude trekking, reliable handheld blood glucose meters (BGMs are necessary. Accurate blood glucose measurement under extreme conditions is paramount for safe recreation at altitude. Prior studies reported bias in blood glucose measurements using different BGMs at high altitude. We hypothesized that glucose-oxidase based BGMs are more influenced by the lower atmospheric oxygen pressure at altitude than glucose dehydrogenase based BGMs. METHODOLOGY/PRINCIPAL FINDINGS: Glucose measurements at simulated altitude of nine BGMs (six glucose dehydrogenase and three glucose oxidase BGMs were compared to glucose measurement on a similar BGM at sea level and to a laboratory glucose reference method. Venous blood samples of four different glucose levels were used. Moreover, two glucose oxidase and two glucose dehydrogenase based BGMs were evaluated at different altitudes on Mount Kilimanjaro. Accuracy criteria were set at a bias 6.5 mmol/L and <1 mmol/L from reference glucose (when <6.5 mmol/L. No significant difference was observed between measurements at simulated altitude and sea level for either glucose oxidase based BGMs or glucose dehydrogenase based BGMs as a group phenomenon. Two GDH based BGMs did not meet set performance criteria. Most BGMs are generally overestimating true glucose concentration at high altitude. CONCLUSION: At simulated high altitude all tested BGMs, including glucose oxidase based BGMs, did not show influence of low atmospheric oxygen pressure. All BGMs, except for two GDH based BGMs, performed within predefined criteria. At true high altitude one GDH based BGM had best precision and accuracy.

  5. In vivo blood glucose quantification using Raman spectroscopy.

    Directory of Open Access Journals (Sweden)

    Jingwei Shao

    Full Text Available We here propose a novel Raman spectroscopy method that permits the noninvasive measurement of blood glucose concentration. To reduce the effects of the strong background signals produced by surrounding tissue and to obtain the fingerprint Raman lines formed by blood analytes, a laser was focused on the blood in vessels in the skin. The Raman spectra were collected transcutaneously. Characteristic peaks of glucose (1125 cm(-1 and hemoglobin (1549 cm(-1 were observed. Hemoglobin concentration served as an internal standard, and the ratio of the peaks that appeared at 1125 cm(-1 and 1549 cm(-1 peaks was used to calculate the concentration of blood glucose. We studied three mouse subjects whose blood glucose levels became elevated over a period of 2 hours using a glucose test assay. During the test, 25 Raman spectra were collected transcutaneously and glucose reference values were provided by a blood glucose meter. Results clearly showed the relationship between Raman intensity and concentration. The release curves were approximately linear with a correlation coefficient of 0.91. This noninvasive methodology may be useful for the study of blood glucose in vivo.

  6. [Activity of Vegetative Nervous System and Levels of Inflammatory Cytokines During Glucose Tolerance Test in Subjects With Optimal and High Normal Blood Pressure].

    Science.gov (United States)

    Mangileva, T A

    2015-01-01

    Fourteen patients with high normal (main group) and 15 subjects with optimal (control group) blood pressure (BP) were examined. Fasting and postprandial (60 and 120 min after oral intake of glucose) levels of glucose, insulin, interleukin (IL)-1β, tumor necrosis factor (TNF)-α, and C-reactive protein were measured. At the same time spectral analysis of heart rate variability (HRV) was done. Body mass index (BMI) and insulin resistance index (as HOMA-IR) were calculated. In patients with high normal BP total power of HRV was decreased (p glucose loading were blunted. In persons with optimal BP transient elevation of low frequency component and low/high ratio in 60 min after onset of glucose tolerance test (GTT) were registered; values of both parameters were higher than in the main group (p control group were accompanied by transient elevations of levels of inflammatory cytokines: IL-10 and TNF-α in 60 min, IL-6 in 120 min after GTT onset (p glucose level 60 min after glucose intake were higher in patients from the main group (p optimal and high normal BP have different variants of vegetative nervous system reactions to pulsatile hyperglycemia which is accompanied by changes of levels of inflammatory cytokines and worsening of carbohydrate metabolism in patients with high normal BP. PMID:26320287

  7. Cord blood testing

    Science.gov (United States)

    ... to evaluate the oxygen, carbon dioxide, and pH levels) Blood sugar level Blood type and Rh Complete blood count ( ... means you have a blood infection (septicemia). High levels of blood sugar (glucose) in the cord blood may be found ...

  8. High and Low Glycemic Index Mixed Meals and Blood Glucose in Youth with Type 2 Diabetes or Impaired Glucose Tolerance

    OpenAIRE

    Gellar, Lauren; Nansel, Tonja R.

    2009-01-01

    This cross-over pilot study tested blood glucose response to low and high glycemic index meals in 12 obese youth with type 2 diabetes or impaired glucose tolerance. Participants demonstrated significantly lower mean daytime blood glucose and a trend toward lower variability, suggesting a clinically relevant impact of reducing glycemic index.

  9. Catecholamine blood test

    Science.gov (United States)

    Norepinephrine -- blood; Epinephrine -- blood; Adrenalin -- blood; Dopamine -- blood ... A blood sample is needed. ... the test. This is especially true if both blood and urine catecholamines are to be measured. You ...

  10. Blood glucose response to pea fiber

    DEFF Research Database (Denmark)

    Hamberg, O; Rumessen, J J; Gudmand-Høyer, E

    1989-01-01

    Two new fiber types, pea fiber (PF) and sugar beet fiber (BF), were compared with wheat bran (WB) to investigate the effect on postprandial blood glucose and serum insulin responses in normal subjects. The control meal consisted of 150 g ground beef mixed with 50 g glucose and 20 g lactulose. Only...... addition of PF (15 g pure fiber) reduced the area under the incremental blood glucose curve significantly (by 65%, p less than 0.05). None of the fibers affected the area under the insulin-response curve significantly although it was reduced by all fibers. Mouth-to-cecum transit time, assessed...

  11. Effects of a healthy Nordic diet on gene expression changes in peripheral blood mononuclear cells in response to an oral glucose tolerance test in subjects with metabolic syndrome

    DEFF Research Database (Denmark)

    Leder, Lena; Kolehmainen, Marjukka; Narverud, Ingunn;

    2016-01-01

    BACKGROUND: Diet has a great impact on the risk of developing features of metabolic syndrome (MetS), type 2 diabetes mellitus (T2DM), and cardiovascular diseases (CVD). We evaluated whether a long-term healthy Nordic diet (ND) can modify the expression of inflammation and lipid metabolism......-related genes in peripheral blood mononuclear cells (PBMCs) during a 2-h oral glucose tolerance test (OGTT) in individuals with MetS. METHODS: A Nordic multicenter randomized dietary study included subjects (n = 213) with MetS, randomized to a ND group or a control diet (CD) group applying an isocaloric study...

  12. 血液标本存放时间及存放方式对血糖检测结果的影响%Influence of storage time and storage way of blood sample on blood glucose testing result

    Institute of Scientific and Technical Information of China (English)

    周正国

    2015-01-01

    Objective To research and observe the influence of storage time and storage way of blood sample on blood glucose testing result, for providing reference for clinical detection in clinical practice. Methods 20 cases were selected randomly, and the patients were collected blood samples with empty belly. 14mL blood was collected for each patient, and 2mL once. The blood samples were stored in vacuum tubes which were marked as control(1), indoor temperature(2), 37℃thermostatic waterbath(2) and 0℃fridge(2). And the influence of storage time and storage way of blood sample on blood glucose testing result was analyzed. Results The influence of storage time of blood on blood glucose test is very evident. After 6h, the blood glucose level was 60%of the initial value. After 18h, he blood glucose level was 27%of initial value.And the blood glucose level after 24 h is 22%of initial value. The longer blood glucose was stored, the faster the blood glucose level reduced. After blood samples were stored in indoor temperature and 37℃thermostatic waterbath for 2.5h and 5h, the blood glucose testing result had evident difference from the initial value, which had statistical significance. Blood samples are stored in sodium fluoride potassium oxalate tube and separation gel coagulant tube, and the influence of it on blood glucose detection had no evident difference, which had no statistical significance. Conclusion In order to ensure that the result of blood glucose detection is accurate, the blood samples should be stored in the environment with low temperature, and the blood samples should be detected timely, to reduce the error of detection results and ensure that the result is reliable and accurate.%目的:研究和探讨血液标本存放时间和存放方式对血糖检测结果的影响,为日后临床检验提供参考价值。方法随机抽取20例患者,空腹采集血液标本,每位患者共采集14mL,每次2mL,存放于真空

  13. Non-Invasive Optical Blood Glucose Measurement

    Directory of Open Access Journals (Sweden)

    Megha C.Pande

    2013-07-01

    Full Text Available The method for noninvasively blood glucose monitoring system is discussed in this paper. Lot of research work has been done in developing the device which is completely noninvasive to avoid the pros & cons because of frequent pricking. In this paper we are trying to analyze the noninvasive blood glucose measurement study in the near infrared region which is the most suitable region for blood glucose measurement. For this purpose we use a technique which is similar to pulseoximetry based on near infrared spectrometry .An infrared light of particular wavelength is passed through fingertip containing an arterial pulse component are derived,thus minimizing influences of basal components such as resting blood volume,skin, muscle and bone.

  14. Performance evaluation of 20 blood glucose meters for home use testing%20台家庭检验血糖仪性能评价

    Institute of Scientific and Technical Information of China (English)

    汪俊汉; 黄刚; 卢蓉; 江虹; 冯敏; 姚伟; 陈艳铭; 胡红云

    2015-01-01

    目的:评价社区家庭检验血糖仪的精密度和准确度。方法应用 ISO15197:2013版“体外诊断检验系统‐自测用血糖监测系统的要求”标准,使用毛细血管血和静脉血,分别用于血糖仪和实验室生化分析仪测定血液葡萄糖浓度,对每台血糖仪与生化分析仪的检测结果进行偏差分析。结果在被评价的20台血糖仪中,全部不能满足 ISO15197:2013版要求(血糖浓度小于5.5 mmol/L 时,≥95%的检测结果偏差在±0.83 mmol/L 范围内;血糖浓度大于或等于 5.5 mmol/L 时,偏差在±15%范围内),只有11台(55%)进口血糖仪达到国家标准。结论20台血糖仪的偏差范围为-28.7%~3.8%,平均偏差为-12.2%,这样的检测结果将给糖尿病患者的治疗带来极大的风险。定期的、规范的血糖仪性能评价能够确保糖尿病患者自我监测血糖的质量。%Objective To evaluate the precision and accuracy of blood glucose meter(BGM ) for community home use testing . Methods According to the In Vitro Diagnostic Test Systems‐Requirements for Blood Glucose Monitoring Systems for Self‐Testing in Managing Diabetes Mellitus in DIN EN ISO15197 :2013 .Capillary blood and venous blood were tested by BGM and the laborato‐ry biochemical analyzer respectively .The measurement results of each BGM were compared with the results of the biochemical ana‐lyzer for conducting the bias analysis .Results In evaluated 20 BGM ,none of them met the requirements of ISO15197 :2013(when blood glucose concentrations < 5 .5 mmol/L ,the bias in 95% of detection results is within the range of ± 0 .83 mmol/L ;when blood glucose concentrations ≥ 5 .5 mmol/L ,the bias in 95% of detection results is within the range of ± 15% .Only 11 imported BGM (55% ) met the state standard .Conclusion The bias of 20 BGM ranged - 28 .7% - 3 .8% ,with the average bias of - 12 .2% . These detection results will bring

  15. Optical coherence tomography for blood glucose monitoring through signal attenuation

    Science.gov (United States)

    De Pretto, Lucas R.; Yoshimura, Tania M.; Ribeiro, Martha S.; de Freitas, Anderson Z.

    2016-03-01

    Development of non-invasive techniques for glucose monitoring is crucial to improve glucose control and treatment adherence in patients with diabetes. Hereafter, Optical Coherence Tomography (OCT) may offer a good alternative for portable glucometers, since it uses light to probe samples. Changes in the object of interest can alter the intensity of light returning from the sample and, through it, one can estimate the sample's attenuation coefficient (μt) of light. In this work, we aimed to explore the behavior of μt of mouse's blood under increasing glucose concentrations. Different samples were prepared in four glucose concentrations using a mixture of heparinized blood, phosphate buffer saline and glucose. Blood glucose concentrations were measured with a blood glucometer, for reference. We have also prepared other samples diluting the blood in isotonic saline solution to check the effect of a higher multiple-scattering component on the ability of the technique to differentiate glucose levels based on μt. The OCT system used was a commercial Spectral Radar OCT with 930 nm central wavelength and spectral bandwidth (FWHM) of 100 nm. The system proved to be sensitive for all blood glucose concentrations tested, with good correlations with the obtained attenuation coefficients. A linear tendency was observed, with an increase in attenuation with higher values of glucose. Statistical difference was observed between all groups (p<0.001). This work opens the possibility towards a non-invasive diagnostic modality using OCT for glycemic control, which eliminates the use of analytes and/or test strips, as in the case with commercially available glucometers.

  16. Blood Count Tests

    Science.gov (United States)

    Your blood contains red blood cells (RBC), white blood cells (WBC), and platelets. Blood count tests measure the number and types of cells in your blood. This helps doctors check on your overall health. ...

  17. Comparison of blood glucose test results between point-of-care testing glucose meter and biochemical analyzer%POCT血糖仪与生化分析仪血糖检测结果的比对试验及分析

    Institute of Scientific and Technical Information of China (English)

    刘加红

    2014-01-01

    Objective To explore precision and accuracy of point-of-care testing(POCT) blood glucose meter through comparing blood glucose results between POCT glucose meter and biochemical analyzer. Methods Selected 4 sets of POCT glucose meter to detect the same sample and compared blood glucose results between Beckman CX-9 biochemical analyzer and POCT blood glucose meter. Results Measured results of Beckman CX-9 biochemical analyzer and POCT glucose meter were highly correlated(P>0.05), differences were not statistically significant. Conclusion POCT blood glucose meter is a consistent and convenient detection method for measuring blood glucose results as biochemical analyzer, so it is worthy of clinical promotion and application.%目的对比床旁检测(POCT)血糖仪与生化分析仪对血糖测定的结果,对POCT血糖仪的精密度与准确度进行探讨。方法选用4台POCT血糖仪对同一标本进行测定,并比较贝克曼CX-9生化分析仪与POCT血糖仪的测定结果。结果贝克曼CX-9生化分析仪与POCT血糖仪的测定结果高度相关(P>0.05),差异不具有统计学意义。结论 POCT血糖仪与生化分析仪对血糖的测定结果具有一致性,且方便快捷,可作为急诊的检测方法,值得在临床过程中推广、应用。

  18. The relationship between type of drug therapy and blood glucose self-monitoring test strips claimed by beneficiaries of the Seniors' Pharmacare Program in Nova Scotia, Canada

    Directory of Open Access Journals (Sweden)

    Sketris Ingrid

    2008-05-01

    Full Text Available Abstract Background The healthcare expenditure on self-monitoring of blood glucose (SMBG test strips under the Nova Scotia Seniors' Pharmacare Program (NSSPP has increased significantly in recent years. The objective of this study was to identify the frequency and cost of claims for blood glucose monitoring test strips by NSSPP beneficiaries in the fiscal year 2005/06 and to explore the variation in the use of test strips by type of treatment, age and sex. Methods Retrospective analysis was conducted using pharmacy administrative claims data for NSSPP beneficiaries. Study subjects were aged ≥ 65 years on October 1, 2004, received SMBG test strips in the 110 days prior to April 1, 2005, and were alive throughout the twelve month study period. Subjects were categorized into four groups: insulin only, oral antihyperglycemic agents (OAA only, both OAA and insulin; and no reimbursed diabetes medications. Statistical analysis was performed to identify differences in expenditure by medication group and in frequency of SMBG test strips claimed by medication group, age, and sex. Results Of 13,564 included beneficiaries, 13.2% were categorized as insulin only, 53.5% OAA only, 7.2% both OAA and insulin, and 26.0% no reimbursed diabetes medications. Over half (58.7% were femle. The insulin only category had the highest mean (± SD number of SMBG test strips claimed per day (2.0 ± 1.5 with a mean annual total cost of $615 ± $441/beneficiary. Beneficiaries aged 80 years and above claimed fewer test strips than beneficiaries below 80 years. Conclusion This population based study shows that in Nova Scotia the SMBG test strips claimed by the majority of seniors were within Canadian guidelines. However, a small proportion of beneficiaries claimed for SMBG test strips infrequently or too frequently, which suggests areas for improvement. The provincial drug plan covers the majority of the costs of test strip utilization, suggesting that the majority of test

  19. Anthrax - blood test

    Science.gov (United States)

    ... The best test for diagnosing anthrax is a culture of affected tissue or blood. Alternative Names Anthrax serology test; Antibody test for anthrax; Serologic test for B anthracis Images Blood test Bacillus anthracis References Hall GS, Woods GL. Medical bacteriology. ...

  20. Lyme disease blood test

    Science.gov (United States)

    ... antibodies in the blood sample using the ELISA test . If the ELISA test is positive, it must be confirmed with another ... were seen in your blood sample. If the ELISA test is negative, usually no other testing is needed. ...

  1. Blood glucose concentration in pediatric outpatient surgery.

    Science.gov (United States)

    Somboonviboon, W; Kijmahatrakul, W

    1996-04-01

    Blood glucose concentration was measured in 84 pediatric patients who were scheduled for outpatient surgery at Chulalongkorn Hospital. They were allocated into 3 groups according to their ages, group 1:less than 1 year of age, group 2:1 to 5 years of age and group 3:over 5 years. The fasting times were approximately 8-12 hours. All patients received standard general anesthesia under mask. No glucose solution was given during operation. Preoperative mean blood glucose were 91.09 +/- 17.34, 89.55 +/- 18.69 and 82.14 +/- 16.14 mg/dl in group 1, 2 and 3 while the postoperative mean glucose values were 129.07 +/- 37.90, 115.62 +/- 29.63 and 111.53 +/- 23.07 mg/dl respectively. The difference between pre- and post-operative values were statistically significant difference (P postoperative glucose values may be due to stress response from surgery and anesthesia. We would suggest that the parents give the fluid to their children according to our instructions in order to prevent dehydration and hypoglycemia especially in small infants.

  2. Critical Care Glucose Point-of-Care Testing.

    Science.gov (United States)

    Narla, S N; Jones, M; Hermayer, K L; Zhu, Y

    2016-01-01

    Maintaining blood glucose concentration within an acceptable range is a goal for patients with diabetes mellitus. Point-of-care glucose meters initially designed for home self-monitoring in patients with diabetes have been widely used in the hospital settings because of ease of use and quick reporting of blood glucose information. They are not only utilized for the general inpatient population but also for critically ill patients. Many factors affect the accuracy of point-of-care glucose testing, particularly in critical care settings. Inaccurate blood glucose information can result in unsafe insulin delivery which causes poor glucose control and can be fatal. Healthcare professionals should be aware of the limitations of point-of-care glucose testing. This chapter will first introduce glucose regulation in diabetes mellitus, hyperglycemia/hypoglycemia in the intensive care unit, importance of glucose control in critical care patients, and pathophysiological variables of critically ill patients that affect the accuracy of point-of-care glucose testing. Then, we will discuss currently available point-of-care glucose meters and preanalytical, analytical, and postanalytical sources of variation and error in point-of-care glucose testing. PMID:27645817

  3. CEA blood test

    Science.gov (United States)

    Carcinoembryonic antigen blood test ... A blood sample is needed . ... When the needle is inserted to draw blood, some people feel moderate pain. Others feel only a prick or stinging sensation. Afterward, there may be some throbbing or a slight bruise. ...

  4. Ketones blood test

    Science.gov (United States)

    ... Ketones - serum; Nitroprusside test; Ketone bodies - serum; Ketones - blood ... A blood sample is needed. ... When the needle is inserted to draw blood, some people feel slight ... there may be some throbbing or a slight bruise. This soon ...

  5. Blood Glucose Measurement Using Bioimpedance Technique

    OpenAIRE

    Kamat, D. K.; Dhanashri Bagul; Patil, P. M.

    2014-01-01

    Bioimpedance measurement is gaining importance in wide field of bioresearch and biomedical systems due to its noninvasive nature. Noninvasive measurement method is very important to decrease infection and physical injuries which result due to invasive measurement. This paper presents basic principle of bioimpedance along with its application for blood glucose analysis and effect of frequency on impedance measurement. Input from bioimpedance sensor is given to amplifier and signal conditioner ...

  6. Blood glucose control and monitoring in the critically ill

    NARCIS (Netherlands)

    R.T.M. van Hooijdonk

    2015-01-01

    This thesis deals with blood glucose control and blood glucose monitoring in intensive care unit (ICU) patients: two important aspects of care for and monitoring of critically ill patients. While the precise targets of blood glucose control in ICU patients remain a matter of debate, currently many,

  7. Influence of Artificial Sweetener on Human Blood Glucose Concentration

    Directory of Open Access Journals (Sweden)

    Ilse Skokan

    2007-01-01

    Full Text Available Artificial sweeteners, such as saccharin or cyclamic acid are synthetically manufactured sweetenings. Known for their low energetic value they serve especially diabetic and adipose patients as sugar substitutes. It has been hypothesized that the substitution of sugar with artificial sweeteners may induce a decrease of the blood glucose. The aim of this study was to determine the reliability of this hypothesis by comparing the influence of regular table sugar and artificial sweeteners on the blood glucose concentration. In this pilot-study 16 patients were included suffering from adiposity, pre-diabetes and hypertension. In the sense of a cross-over design, three test trials were performed at intervals of several weeks. Each trial was followed by a test free interval. Within one test trial each patient consumed 150 ml test solution (water that contained either 6 g of table sugar (“Kandisin” with sweetener free serving as control group. Tests were performed within 1 hr after lunch to ensure conditions comparable to patients having a desert. Every participant had to determine their blood glucose concentration immediately before and 5, 15, 30 and 60 minutes after the intake of the test solution. For statistics an analysis of variance was performed. The data showed no significant changes in the blood glucose concentration. Neither the application of sugar (F4;60 = 1.645; p = .175 nor the consumption of an artificial sweetener (F2.068;31.023 = 1.551; p > .05 caused significant fluctuations in the blood sugar levels. Over a time frame of 60 minutes in the control group a significant decrease of the blood sugar concentration was found (F2.457;36.849 = 4.005; p = .020 as a physiological reaction during lunch digestion.

  8. Blood-Brain Glucose Transfer: Repression in Chronic Hyperglycemia

    Science.gov (United States)

    Gjedde, Albert; Crone, Christian

    1981-10-01

    Diabetic patients with increased plasma glucose concentrations may develop cerebral symptoms of hypoglycemia when their plasma glucose is rapidly lowered to normal concentrations. The symptoms may indicate insufficient transport of glucose from blood to brain. In rats with chronic hyperglycemia the maximum glucose transport capacity of the blood-brain barrier decreased from 400 to 290 micromoles per 100 grams per minute. When plasma glucose was lowered to normal values, the glucose transport rate into brain was 20 percent below normal. This suggests that repressive changes of the glucose transport mechanism occur in brain endothelial cells in response to increased plasma glucose.

  9. EFFECT OF FIBER SUPPLEMENT ON BLOOD GLUCOSE LEVEL OF NIDDM SUBJECTS

    OpenAIRE

    Seema V Medhe* and Mangal V Medhe

    2013-01-01

    An investigation was undertaken to assess effect of fiber rich supplement on blood glucose level of type 2 diabetic patients. Fiber rich supplement was tested on eleven type 2 diabetic subjects for blood glucose lowering effect by undertaking an intervention of two months feeding trials. Results with respect to two months supplementation indicated that the fiber rich supplement was helpful in significantly reducing the fasting and postprandial blood glucose level of subjects. The reduction in...

  10. Prediction Methods for Blood Glucose Concentration

    DEFF Research Database (Denmark)

    “Meta-Learning Based Blood Glucose Predictor for DiabeticSmartphone App” by Valeriya Naumova et al. demonstrates how a highly sophisticated glucose prediction model can be ported from a development language running on a PC to a format such that it can be used conveniently by the patients. A unique...... Continuous EEG Monitoring” by Claus Borg Juhl et al. shows how to use EEG signals to predict upcoming hypoglycemic situations in real-time by employing artificial neural networks. The results of a 30-day long clinical study with the implanted device and the developed algorithm are presented. The chapter......-Based Linear Multistep Predictors” by Marzia Cescon et al. uses data-based methods to develop individualized prediction models. The model can be considered as a combination of physiological models to precompute the rate of appearance of injected insulin and ingested carbohydrates in the bloodstream and of data...

  11. BUN - blood test

    Science.gov (United States)

    Blood urea nitrogen ... A blood sample is needed. Most of the time blood is drawn from a vein located on the inside ... Many medicines can interfere with blood test results. Your health ... if you need to stop taking any medicines before you have this ...

  12. Factors affecting initial training success of blood glucose testing in captive chimpanzees (Pan troglodytes)

    DEFF Research Database (Denmark)

    Reamer, Lisa A; Haller, Rachel L; Thiele, Erica J;

    2014-01-01

    the entire procedure in one session, without any prior specific training for the target behavior. Factors that affected this initial successful BG testing included sex, personality (chimpanzees rated higher on the factor "openness" were more likely to participate with BG testing), and past training...... participation of 123 chimpanzees in BG sampling and investigated factors that may contribute to individual success. All subjects participate in regular PRT sessions as part of a comprehensive behavioral management program. Basic steps involved in obtaining BG values include: voluntarily presenting a finger...... important implications for captive management and training program success, underlining individual differences in training aptitude and the need for developing individual management plans in order to provide optimal care and treatment for diabetic chimpanzees in captivity....

  13. Blood Glucose Measurement Using Bioimpedance Technique

    Directory of Open Access Journals (Sweden)

    D. K. Kamat

    2014-01-01

    Full Text Available Bioimpedance measurement is gaining importance in wide field of bioresearch and biomedical systems due to its noninvasive nature. Noninvasive measurement method is very important to decrease infection and physical injuries which result due to invasive measurement. This paper presents basic principle of bioimpedance along with its application for blood glucose analysis and effect of frequency on impedance measurement. Input from bioimpedance sensor is given to amplifier and signal conditioner AD5933. AD5933 is then interfaced with microcontroller LPC1768 using I2C bus for displaying reading on LCD. Results can also be stored in database using UART interface of LPC1768.

  14. Application of transcutaneous diffuse reflectance spectroscopy in the measurement of blood glucose concentration

    Institute of Scientific and Technical Information of China (English)

    Wenliang Chen(陈文亮); Rong Liu(刘蓉); Houxin Cui(崔厚欣); Kexin Xu(徐可欣); Lina Lü(吕丽娜)

    2004-01-01

    In this paper, the propagation characteristics of near-infrared (NIR) light in the palm tissue are analyzed,and the principle and feasibility of using transcutaneous diffuse reflectance spectroscopy for non-invasive blood glucose detection are presented. An optical probe suitable for measuring the diffuse reflectance spectrum of human palm and a non-invasive blood glucose detection system using NIR spectroscopy are designed. Based on this system, oral glucose tolerance tests are performed to measure the blood glucose concentrations of two young healthy volunteers. The partial least square calibration model is then constructed by all individual experimental data. The final result shows that correlation coefficients of the two experiments between the predicted blood glucose concentrations and the reference blood glucose concentrations are 0.9870 and 0.9854, respectively. The root mean square errors of prediction of full cross validation are 0.54 and 0.52 mmol/1, respectively.

  15. The Effects of Blood Glucose Levels on Cognitive Performance: A Review of the Literature

    Science.gov (United States)

    Feldman, Jolene; Barshi, Immanuel

    2007-01-01

    The purpose of this review paper is to discuss the research literature on the effects of blood glucose levels on executive and non-executive functions in humans. The review begins with a brief description of blood glucose, how it has been studied, previous syntheses of prior studies, and basic results regarding the role of blood glucose on cognitive functioning. The following sections describe work that investigated the effect of blood glucose on both non-executive and executive functions (e.g., sensory processing, psychomotor functioning, attention, vigilance, memory, language and communication, judgement and decision-making, and complex task performance). Within each section, summaries of the findings and challenges to the literature are included. Measurement conversions of blood glucose levels, blood glucose values, and associated symptoms are depicted. References to the types of tests used to investigate blood glucose and cognitive performance are provided. For more detailed descriptions of references within (and in addition to) this paper, an annotated bibliography is also provided. Several moderator variables including individual differences and contextual variables related to the effects of blood glucose levels on performance (e.g., age, gender, time of day, familiarity with the task and symptom awareness, expectancy effects, dose dependent effects, time dependent effects, task specific effects, rising and falling blood glucose levels, and speed and/or accuracy trade-offs) are addressed later in the paper. Some suggestions for future experimental methodologies are also made.

  16. Vitamin A blood test

    Science.gov (United States)

    ... this page: //medlineplus.gov/ency/article/003570.htm Vitamin A blood test To use the sharing features on this page, please enable JavaScript. The vitamin A test measures the level of vitamin A ...

  17. CO2 blood test

    Science.gov (United States)

    Bicarbonate test; HCO3-; Carbon dioxide test; TCO2; Total CO2; CO2 test - serum ... Many medicines can interfere with blood test results. Your health care provider will tell you if you need to stop taking any medicines before you have this test. DO ...

  18. THE EFFECT OF AVOCADO (PERSEA AMERICANA MILL.) LEAVES EXTRACT TOWARDS THE MOUSE'S BLOOD GLUCOSE DECREASE WITH THE GLUCOSE TOLERANCE METHOD

    OpenAIRE

    Shirly Kumala*, Hesty Utami and Wahyu Kartika Sari

    2013-01-01

    Decrease in blood glucose level test with the use of oral glucose tolerance method from Avocado leaves was carried out. Swiss Webster male mice were divided randomly into five groups. They were negative control, positive control (Glipizide 0.013 mg/20 g BW) and three test groups treated with dosage of avocado leaves ethanol extract 0.490 g/kg, 0.980 g/kg and 1.960 g /BW respectively. Experiment was begun with feeding the mice with the test solution followed by feeding glucose solution (1.5 g/...

  19. Blood Test: Bilirubin

    Science.gov (United States)

    ... the blood. Babies with high levels may need phototherapy (treatment with a special light that makes bilirubin ... are afraid of needles. Explaining the test in terms your child can understand might help ease some ...

  20. Home blood glucose concentrations in maturity-onset diabetes.

    OpenAIRE

    Paisey, R B; Bradshaw, P; Hartog, M.

    1980-01-01

    Blood glucose concentrations during normal daily activities were measured in 106 patients with maturity-onset diabetes from capillary blood samples collected on to filter paper. Samples were taken before and two hours after main meals, before going to bed, and, in 51 cases, during the night. Fasting and mid-morning values were closely correlated with the mean values over 24 hours irrespective of the type of anti-diabetic treatment being given. Postprandial blood glucose concentrations remaine...

  1. 全自动生化分析仪检测血糖的校准验证%Calibration verification for blood glucose test in automatic biochemistry analyzers

    Institute of Scientific and Technical Information of China (English)

    周琦; 谢伟; 徐建平; 李少男; 李小鹏

    2012-01-01

    Objective To perform calibration verification for the blood glucose test in Hitachi and Olympus automatic biochemistry analyzers and present a method of calibration verification and evaluate the results.Methods The glucose test results were divided into two groups:Hitachi and Olympus groups according to the different analytical instruments.The calibration verification was performed following the current College of American Pathologists strategies.The slope and intercept of the calibration line were tested by one-sample t test and the percentage differences were calculated.The percentage differences were compared with allowable errors.If the slope and intercept had no statistically significant difference from 1 and 0 respectively and the percentage differences were within the limits of allowable errors,the calibration line was evaluated as verified 1 ; if the slope and intercept had no statistically significant difference from 1 and 0 respectively and at least one of the percentage differences exceeded the limits of allowable errors,the calibration line was evaluated as different 1 ; if the slope or intercept had statistically significant difference from 1 and 0 respectively and the percentage differences were within the limits of allowable errors,the calibration line was evaluated as verified 2; if the slope or intercept had statistically significant difference from 1 and 0 respectively and at least one of the percentage differences exceeded the limits of allowable errors,the calibration line was evaluated as different 2.Results In Hitachi group,verified 1,different 1,verified 2 and different 2 were 5.4% ( 4/74 ),0.0% ( 0/74 ),68.9% ( 51/74 ) and 25.7% ( 19/74 ),respectively.In Olympus group,verified 1,different 1,verified 2 and different 2 were 16.4% (12/73),0.0% (0/73),58.9% (43/73) and 24.7% ( 18/73 ),respectively.Conclusions The current College of American Pathologist strategies could be performed as a reasonable and feasible method for

  2. High Blood Glucose: What It Means and How To Treat It

    Science.gov (United States)

    ... Blood Glucose: What It Means and How To Treat It What is high blood glucose? People who ... to keep your blood glucose under control, and treat hyperglycemia when it occurs. What are the symptoms ...

  3. Luteinizing hormone (LH) blood test

    Science.gov (United States)

    ICSH - blood test; Luteinizing hormone - blood test; Interstitial cell stimulating hormone - blood test ... medicines you take. These include: Birth control pills Hormone therapy Testosterone DHEA (a supplement) If you are ...

  4. Self-monitoring of tear glucose: the development of a tear based glucose sensor as an alternative to self-monitoring of blood glucose.

    Science.gov (United States)

    La Belle, Jeffrey T; Adams, Anngela; Lin, Chi-En; Engelschall, Erica; Pratt, Breanna; Cook, Curtiss B

    2016-07-28

    Tear glucose sensing for diabetes management has long been sought as an alternative to more invasive self-monitoring of blood glucose (SMBG). However, tear glucose sensors were known to have limitations, including correlation issues with blood glucose due to low sample volume, low concentration of glucose in the tear fluid, and evaporation of the tear sample. An engineering design approach to solve these problems led to the development of an integrated device capable of collecting the tear sample from the ocular surface with little to no stress on the eye, with an extremely low limit of detection, broad dynamic range, and rapid detection and analysis of sample. Here we present the development of a prototypical self-monitoring of tear glucose (SMTG) sensor, summarizing bench studies on the enzymes and their specificity, the development of the fluid capture device and its manufacture and performance and results of system testing in an animal study where safety, lag time and tear glucose to blood glucose correlation were assessed. PMID:27327531

  5. Polarization Sensitive Optical Coherence Tomography for Blood Glucose Monitoring in Human Subjects

    CERN Document Server

    Solanki, Jitendra; Sen, Pratima; Andrews, Joseph Thomas

    2012-01-01

    A device based on Polarization sensitive optical coherence tomography is developed to monitor blood glucose levels in human subjects. The device was initially tested with tissue phantom. The measurements with human subjects for various glucose concentration levels are found to be linearly dependent on the degree of circular polarization obtainable from the PS-OCT.

  6. Glucagon-like peptide-1 inhibits blood-brain glucose transfer in humans

    DEFF Research Database (Denmark)

    Lerche, Susanne; Brock, Birgitte; Rungby, Jørgen;

    2008-01-01

    demonstrated that a hormone involved in postprandial glucose regulation also limits glucose delivery to brain tissue and hence provides a possible regulatory mechanism for the link between plasma glucose and brain glucose. Because GLP-1 reduces glucose uptake across the intact blood-brain barrier at normal...... glycemia, GLP-1 may also protect the brain by limiting intracerebral glucose fluctuation when plasma glucose is increased.......OBJECTIVE: Glucagon-like peptide-1 (GLP-1) has many effects on glucose homeostasis, and GLP-1 receptors are broadly represented in many tissues including the brain. Recent research in rodents suggests a protective effect of GLP-1 on brain tissue. The mechanism is unknown. We therefore tested...

  7. Flushable reagent stool blood test

    Science.gov (United States)

    Stool occult blood test - flushable home test; Fecal occult blood test - flushable home test ... This test is performed at home with disposable pads. You can buy the pads at the drug store without ...

  8. Monitoring of tissue optical properties using OCT: application for blood glucose analysis

    Science.gov (United States)

    Larin, Kirill V.; Eledrisi, Mohsen S.; Ashitkov, Taras V.; Motamedi, Massoud; Esenaliev, Rinat O.

    2002-07-01

    Noninvasive monitoring of tissue optical properties in real time could significantly improve diagnostics and management of various diseases. Recently we proposed to use high- resolution Optical Coherence Tomography (OCT) technique for measurement of tissue scattering coefficient at the depth of up to 1mm. Our pilot studies performed in vitro and in vivo demonstrated that measurement of tissue scattering with this technique can potentially be applied for noninvasive monitoring of blood glucose concentration. High resolution and coherent photon detection of the OCT technique allowed detection of glucose-induced changes in the scattering coefficient. In this paper we report results of in vivo studies performed in dog, New Zealand rabbits, and first human subjects. OCT system with the wavelength of 1300 nm was used in our experiments. OCT signal slope was measured and compared with actual blood glucose concentration. Bolus glucose injections and glucose clamping administrations were used in animal studies. OCT signals were recorded form human subjects during oral glucose tolerance test. Results obtained form both animal and human studies show good correlation between slope of the OCT signals and actual blood glucose concentration measured using standard glucometesr. Sensitivity and accuracy of blood glucose concentrations monitoring with the OCT is discussed. Obtained result suggest that OCT is a promising technique for noninvasive monitoring of tissue analytes including glucose.

  9. A data driven nonlinear stochastic model for blood glucose dynamics.

    Science.gov (United States)

    Zhang, Yan; Holt, Tim A; Khovanova, Natalia

    2016-03-01

    The development of adequate mathematical models for blood glucose dynamics may improve early diagnosis and control of diabetes mellitus (DM). We have developed a stochastic nonlinear second order differential equation to describe the response of blood glucose concentration to food intake using continuous glucose monitoring (CGM) data. A variational Bayesian learning scheme was applied to define the number and values of the system's parameters by iterative optimisation of free energy. The model has the minimal order and number of parameters to successfully describe blood glucose dynamics in people with and without DM. The model accounts for the nonlinearity and stochasticity of the underlying glucose-insulin dynamic process. Being data-driven, it takes full advantage of available CGM data and, at the same time, reflects the intrinsic characteristics of the glucose-insulin system without detailed knowledge of the physiological mechanisms. We have shown that the dynamics of some postprandial blood glucose excursions can be described by a reduced (linear) model, previously seen in the literature. A comprehensive analysis demonstrates that deterministic system parameters belong to different ranges for diabetes and controls. Implications for clinical practice are discussed. This is the first study introducing a continuous data-driven nonlinear stochastic model capable of describing both DM and non-DM profiles.

  10. Prediction methods for blood glucose concentration design, use and evaluation

    CERN Document Server

    Jørgensen, John; Renard, Eric; Re, Luigi

    2016-01-01

    This book tackles the problem of overshoot and undershoot in blood glucose levels caused by delay in the effects of carbohydrate consumption and insulin administration. The ideas presented here will be very important in maintaining the welfare of insulin-dependent diabetics and avoiding the damaging effects of unpredicted swings in blood glucose – accurate prediction enables the implementation of counter-measures. The glucose prediction algorithms described are also a key and critical ingredient of automated insulin delivery systems, the so-called “artificial pancreas”. The authors address the topic of blood-glucose prediction from medical, scientific and technological points of view. Simulation studies are utilized for complementary analysis but the primary focus of this book is on real applications, using clinical data from diabetic subjects. The text details the current state of the art by surveying prediction algorithms, and then moves beyond it with the most recent advances in data-based modeling o...

  11. Temperature influence on non-invasive blood glucose measurement

    Science.gov (United States)

    Zhang, Xiqin; Yeo, Joon Hock

    2009-02-01

    Regular monitoring of blood sugar level is important for the management of diabetes. The Near-Infra-Red (NIR) spectroscopy method is a promising approach and this involves some form of contact with the body skin. It is noted that the skin temperature does fluctuate with the environment and physiological conditions and the temperature has an influence on the glucose measurement. In this paper, in-vitro and in-vivo investigations on the temperature influence on blood glucose measurement were studied. The in-vitro results from FTIR spectrometer show that sample temperature has significant influence on water absorption, which significantly affects the glucose absorption measurement. The in-vivo results show that when skin temperature around the measurement site is taken into consideration, the prediction of blood glucose level greatly improves.

  12. Self-Blood Glucose Monitoring in Diabetes Mellitus (Beyond the Basics)

    Science.gov (United States)

    ... Use ©2016 UpToDate, Inc. Patient education: Self-blood glucose monitoring in diabetes mellitus (Beyond the Basics) Author ... 2016. | This topic last updated: Oct 19, 2015. BLOOD SUGAR TESTING OVERVIEW — If you have diabetes, you have ...

  13. Prediction Methods for Blood Glucose Concentration

    DEFF Research Database (Denmark)

    measurements which are also subject to measurement errors. Inaccurate measurements will directly affect the performance of the corresponding predictions. The chapter “CGM — How Good Is Good Enough?” by Michael Schoemaker and Christopher G. Parkin also tackles the problem of continuous glucose monitor...

  14. Use of a blood glucose meter for radiochromic film analysis in blood irradiation

    International Nuclear Information System (INIS)

    The use of a diabetic blood glucose meter for radiochromic film dosimetry in blood irradiation using x-ray beams on a medical linear accelerator has been investigated. The glucose meter provides optical density analysis in the visible and infrared region using a reflectance measurement technique. By comparing the 'blood sugar' level output with standard calibration gafchromic films a calibration curve is produced for quantitative analysis. Results show that a reproducible dose to meter output curve can be fitted using a second order polynomial function and that blood irradiation doses in vitro were measured to within 7.9% mean error (as compared to ionization chamber results) using the blood glucose meter. This level of accuracy falls below that measured with a standard densitometer (4.3%); however, results show that the blood glucose meter, which would be available in any haematology department, produces an adequate measure of gafchromic film optical density for blood irradiation dosimetry. (author)

  15. A vitamin, mineral, herb dietary supplement effect on blood glucose in uncontrolled type II diabetic subjects.

    Science.gov (United States)

    González, Michael J; Ricart, Carlos M; Miranda-Massari, Jorge

    2004-06-01

    We tested a dietary supplement formulated with a synergistic combination of vitamins, minerals, herbals in a group of 15 patients with uncontrolled diabetes type II. The supplement was given for 30 days. Fasting blood glucose was measured prior to the supplementation and at the end of the 30 days treatment period. Blood glucose was significantly reduced in all patients with no adverse effects. This orthomolecular correction of faulty glucose metabolism with a combination of nontoxic, safe and fairly inexpensive nutraceuticals needs to be further substantiated. Nervertheless the idea of correcting metabolism with micronutrients is a new concept of genetic nutritioneering that seems appealing and cost effective. PMID:15377060

  16. Delaying time to first nocturnal void may have beneficial effects on reducing blood glucose levels.

    Science.gov (United States)

    Juul, Kristian Vinter; Jessen, Niels; Bliwise, Donald L; van der Meulen, Egbert; Nørgaard, Jens Peter

    2016-09-01

    Experimental studies disrupting sleep and epidemiologic studies of short sleep durations indicate the importance of deeper and longer sleep for cardiometabolic health. We examined the potential beneficial effects of lengthening the first uninterrupted sleep period (FUSP) on blood glucose. Long-term data (≥3 months of treatment) were derived from three clinical trials, testing low-dose (10-100 µg) melt formulations of desmopressin in 841 male and female nocturia patients (90 % of which had nocturnal polyuria). We performed post hoc multiple regression with non-fasting blood glucose as dependent variable and the following potential covariates/factors: time-averaged change of FUSP since baseline, age, gender, race, ethnicity, baseline glucose, baseline weight, change in weight, patient metabolic status (normal, metabolic syndrome, type II diabetes), dose, follow-up interval, and time of random glucose sampling. Increases in FUSP resulted in statistically significant reductions in blood glucose (p = 0.0131), even after controlling for all remaining covariates. Per hour increase in time to first void was associated with glucose decreases of 1.6 mg/dL. This association was more pronounced in patients with increased baseline glucose levels (test of baseline glucose by FUSP change interaction: p < 0.0001). Next to FUSP change, other statistically significant confounding factors/covariates also associated with glucose changes were gender, ethnicity, metabolic subgroup, and baseline glucose. These analyses indicate that delaying time to first void may have beneficial effects on reducing blood glucose in nocturia patients. These data are among the first to suggest that improving sleep may have salutary effects on a cardiometabolic measure. PMID:27003433

  17. Magnesium blood test

    Science.gov (United States)

    Magnesium - blood ... A blood sample is needed. ... When the needle is inserted to draw blood, some people feel slight pain. Others feel a prick or stinging. Afterward, there may be some throbbing or a slight bruise. This soon ...

  18. Inhaled insulin for controlling blood glucose in patients with diabetes

    Directory of Open Access Journals (Sweden)

    Bernard L Silverman

    2008-01-01

    Full Text Available Bernard L Silverman1, Christopher J Barnes2, Barbara N Campaigne3, Douglas B Muchmore31Alkermes, Inc, Cambridge, MA, USA; 2i3 Statprobe, Ann Arbor, MI; 3Eli Lilly and Company, Indianapolis, IN, USAAbstract: Diabetes mellitus is a significant worldwide health problem, with the incidence of type 2 diabetes increasing at alarming rates. Insulin resistance and dysregulated blood glucose control are established risk factors for microvascular complications and cardiovascular disease. Despite the recognition of diabetes as a major health issue and the availability of a growing number of medications designed to counteract its detrimental effects, real and perceived barriers remain that prevent patients from achieving optimal blood glucose control. The development and utilization of inhaled insulin as a novel insulin delivery system may positively influence patient treatment adherence and optimal glycemic control, potentially leading to a reduction in cardiovascular complications in patients with diabetes.Keywords: diabetes, inhaled insulin, cardiovascular disease, blood glucose

  19. 便携式血糖仪与全自动生化分析仪测定血糖的比对分析%Blood Glucose Test: A Comparison Study between Portable Glucometer and Automatic Biochemical Analyzer

    Institute of Scientific and Technical Information of China (English)

    王敏; 刘群

    2012-01-01

      Objective To verify the consistency of the blood glucose test results among laboratories, by performing the comparison study between the portable glucometers in the clinical departments and the automatic biochemical analyzer in the clinical laboratory. Methods The comparison of the blood glucose test results from 12 sets of Johnson SureStep glucometers(Glucose Oxidase Method) and Hitach 7080 automatic biochemical analyzer(Hexose Kinase Method) for 50 specimens of low, middle and high blood glucose levels was performed. The difference of each level from each glucometers was analyzed. Results The difference from No. 12 Johnson SureStep glucometer was out of the limit: ± 0.83mmol/L at the extremely low level of less than 2.8mmol/L; and the relative deviation was more than 20% for 4 specimens at middle and high levels(≥4.2mmol/L), and it was deemed unacceptable. The difference from other 11 sets of Johnson SureStep glucometers fall in between -0.63mmol/L and 0.66mmol/L at low level(20%,判为不合格.其余11台血糖仪测定低水平(<4.2mmol/L)血糖标本偏差介于-0.63~0.66mmol/L,中、高水平(≥4.2mmol/L)时,相对偏差为-16.2%~15.8%,且与全自动生化分析仪检测血浆结果有良好的相关性(r 2≥0.950).结论便携式血糖仪检测与生化分析仪检测血糖结果一致性较好,检测结果可靠,但应做好便携血糖仪室内质控及每半年与检验科的比对.

  20. Whole blood glucose analysis based on smartphone camera module.

    Science.gov (United States)

    Devadhasan, Jasmine Pramila; Oh, Hyunhee; Choi, Cheol Soo; Kim, Sanghyo

    2015-11-01

    Complementary metal oxide semiconductor (CMOS) image sensors have received great attention for their high efficiency in biological applications. The present work describes a CMOS image sensor-based whole blood glucose monitoring system through a point-of-care (POC) approach. A simple poly-ethylene terephthalate (PET) chip was developed to carry out the enzyme kinetic reaction at various concentrations (110–586 mg∕dL) of mouse blood glucose. In this technique, assay reagent is immobilized onto amine functionalized silica (AFSiO2) nanoparticles as an electrostatic attraction in order to achieve glucose oxidation on the chip. The assay reagent immobilized AFSiO2 nanoparticles develop a semi-transparent reaction platform, which is technically a suitable chip to analyze by a camera module. The oxidized glucose then produces a green color according to the glucose concentration and is analyzed by the camera module as a photon detection technique; the photon number decreases when the glucose concentration increases. The combination of these components, the CMOS image sensor and enzyme immobilized PET film chip, constitute a compact, accurate, inexpensive, precise, digital, highly sensitive, specific, and optical glucose-sensing approach for POC diagnosis. PMID:26524683

  1. Whole blood glucose analysis based on smartphone camera module

    Science.gov (United States)

    Devadhasan, Jasmine Pramila; Oh, Hyunhee; Choi, Cheol Soo; Kim, Sanghyo

    2015-11-01

    Complementary metal oxide semiconductor (CMOS) image sensors have received great attention for their high efficiency in biological applications. The present work describes a CMOS image sensor-based whole blood glucose monitoring system through a point-of-care (POC) approach. A simple poly-ethylene terephthalate (PET) chip was developed to carry out the enzyme kinetic reaction at various concentrations (110-586 mg/dL) of mouse blood glucose. In this technique, assay reagent is immobilized onto amine functionalized silica (AFSiO2) nanoparticles as an electrostatic attraction in order to achieve glucose oxidation on the chip. The assay reagent immobilized AFSiO2 nanoparticles develop a semi-transparent reaction platform, which is technically a suitable chip to analyze by a camera module. The oxidized glucose then produces a green color according to the glucose concentration and is analyzed by the camera module as a photon detection technique; the photon number decreases when the glucose concentration increases. The combination of these components, the CMOS image sensor and enzyme immobilized PET film chip, constitute a compact, accurate, inexpensive, precise, digital, highly sensitive, specific, and optical glucose-sensing approach for POC diagnosis.

  2. Using meta-differential evolution to enhance a calculation of a continuous blood glucose level.

    Science.gov (United States)

    Koutny, Tomas

    2016-09-01

    We developed a new model of glucose dynamics. The model calculates blood glucose level as a function of transcapillary glucose transport. In previous studies, we validated the model with animal experiments. We used analytical method to determine model parameters. In this study, we validate the model with subjects with type 1 diabetes. In addition, we combine the analytic method with meta-differential evolution. To validate the model with human patients, we obtained a data set of type 1 diabetes study that was coordinated by Jaeb Center for Health Research. We calculated a continuous blood glucose level from continuously measured interstitial fluid glucose level. We used 6 different scenarios to ensure robust validation of the calculation. Over 96% of calculated blood glucose levels fit A+B zones of the Clarke Error Grid. No data set required any correction of model parameters during the time course of measuring. We successfully verified the possibility of calculating a continuous blood glucose level of subjects with type 1 diabetes. This study signals a successful transition of our research from an animal experiment to a human patient. Researchers can test our model with their data on-line at https://diabetes.zcu.cz. PMID:27393799

  3. A Microwave Metamaterial Inspired Sensor for Non-Invasive Blood Glucose Monitoring

    Directory of Open Access Journals (Sweden)

    J. Vrba

    2015-12-01

    Full Text Available In this paper, a microwave sensor based on an artificial transmission line is proposed for non-invasive blood glucose monitoring. A corresponding numerical model of the sensor implemented in microstrip technology is created in the commercial full-wave numerical simulation tool COMSOL Multiphysics and virtually tested by means of numerical simulations. Blood-glucose solution models with various blood glucose concentrations are used as a model of a biological tissue under test. Furthermore, a possible methodology for performing non-invasive tests is proposed. Sensitivity of the sensor developed here is compared to a sensor based on a section of a conventional microstrip transmission line of the same length and width.

  4. Aspartate aminotransferase (AST) blood test

    Science.gov (United States)

    ... Saunders; 2016:chap 73. Read More Acute kidney failure Acute pancreatitis Alanine transaminase (ALT) blood test ALP - blood test Burns Cardiac catheterization Enzyme Heart attack Hemolytic anemia Hepatic Liver cancer - hepatocellular carcinoma Liver disease Mononucleosis Muscular ...

  5. A comprehensive evaluation of strip performance in multiple blood glucose monitoring systems.

    Science.gov (United States)

    Katz, Laurence B; Macleod, Kirsty; Grady, Mike; Cameron, Hilary; Pfützner, Andreas; Setford, Steven

    2015-05-01

    Accurate self-monitoring of blood glucose is a key component of effective self-management of glycemic control. Accurate self-monitoring of blood glucose results are required for optimal insulin dosing and detection of hypoglycemia. However, blood glucose monitoring systems may be susceptible to error from test strip, user, environmental and pharmacological factors. This report evaluated 5 blood glucose monitoring systems that each use Verio glucose test strips for precision, effect of hematocrit and interferences in laboratory testing, and lay user and system accuracy in clinical testing according to the guidelines in ISO15197:2013(E). Performance of OneTouch(®) VerioVue™ met or exceeded standards described in ISO15197:2013 for precision, hematocrit performance and interference testing in a laboratory setting. Performance of OneTouch(®) Verio IQ™, OneTouch(®) Verio Pro™, OneTouch(®) Verio™, OneTouch(®) VerioVue™ and Omni Pod each met or exceeded accuracy standards for user performance and system accuracy in a clinical setting set forth in ISO15197:2013(E). PMID:25702769

  6. Predicting Mortality of Critically Ill Patients by Blood Glucose Levels

    Directory of Open Access Journals (Sweden)

    Byung Sam Park

    2013-10-01

    Full Text Available BackgroundThe aim of this study is to observe the outcome of critically ill patients in relation to blood glucose level at admission and to determine the optimal range of blood glucose at admission predicting lower hospital mortality among critically ill patients.MethodsWe conducted a retrospective cohort study of a total 1,224 subjects (males, 798; females, 426 admitted to intensive care unit (ICU from 1 January 2009 to 31 December 2010. Blood glucose levels at admission were categorized into four groups (group 1, <100 mg/dL; group 2, 100 to 199 mg/dL; group 3, 200 to 299 mg/dL; and group 4, ≥300 mg/dL.ResultsAmong 1,224 patients, 319 patients were already known diabetics, and 296 patients died in ICU. Five hundred fifty-seven subjects received insulin therapy, and 118 received oral hypoglycemic agents. The overall mortality rate was 24.2% (296 patients. The causes of death and mortality rates of diabetic patients were not different from nondiabetic subjects. The mortality curve showed J shape, and there were significant differences in mortality between the groups of blood glucose levels at admission. Group 2 had the lowest mortality rate (P<0.05.ConclusionThese results suggest that serum glucose levels upon admission into ICU is associated with clinical outcomes in ICU patients. Blood glucose level between 100 and 199 mg/dL at the time of ICU admission could predict lower hospital mortality among critically ill patients.

  7. Effects of MDMA on blood glucose levels and brain glucose metabolism

    Energy Technology Data Exchange (ETDEWEB)

    Soto-Montenegro, M.L.; Vaquero, J.J.; Garcia-Barreno, P.; Desco, M. [Hospital General Universitario Gregorio Maranon, Laboratorio de Imagen, Medicina Experimental, Madrid (Spain); Arango, C. [Hospital General Gregorio Maranon, Departamento de Psiquiatria, Madrid (Spain); Ricaurte, G. [Johns Hopkins University School of Medicine, Department of Neurology, Baltimore, MD (United States)

    2007-06-15

    This study was designed to assess changes in glucose metabolism in rats administered single or repeated doses of MDMA. Two different experiments were performed: (1) A single-dose study with four groups receiving 20 mg/kg, 40 mg/kg, saline or heat, and (2) a repeated-dose study with two groups receiving three doses, at intervals of 2 h, of 5 mg/kg or saline. Rats were imaged using a dedicated small-animal PET scanner 1 h after single-dose administration or 7 days after repeated doses. Glucose metabolism was measured in 12 cerebral regions of interest. Rectal temperature and blood glucose were monitored. Peak body temperature was reached 1 h after MDMA administration. Blood glucose levels decreased significantly after MDMA administration. In the single-dose experiment, brain glucose metabolism showed hyperactivation in cerebellum and hypo-activation in the hippocampus, amygdala and auditory cortex. In the repeated-dose experiment, brain glucose metabolism did not show any significant change at day 7. These results are the first to indicate that MDMA has the potential to produce significant hypoglycaemia. In addition, they show that MDMA alters glucose metabolism in components of the motor, limbic and somatosensory systems acutely but not on a long-term basis. (orig.)

  8. Blood Glucose Control in Type 1 Diabetes With a Bihormonal Bionic Endocrine Pancreas

    OpenAIRE

    Russell, Steven J.; El-Khatib, Firas H.; Nathan, David M.; Magyar, Kendra L.; Jiang, John; Damiano, Edward R.

    2012-01-01

    OBJECTIVE To test whether safe and effective glycemic control could be achieved in type 1 diabetes using a bihormonal bionic endocrine pancreas driven by a continuous glucose monitor in experiments lasting more than two days and including six high-carbohydrate meals and exercise as challenges to glycemic control. RESEARCH DESIGN AND METHODS Six subjects with type 1 diabetes and no endogenous insulin secretion participated in two 51-h experiments. Blood glucose was managed with a bionic endocr...

  9. Exposure-based treatment to control excessive blood glucose monitoring.

    OpenAIRE

    Allen, K D; Evans, J. H.

    2001-01-01

    We investigated an exposure-based procedure for reducing excessive checking of blood glucose by a child with diabetes. In a changing criterion design, an exposure-based procedure was implemented by systematically exposing the child to decreasing amounts of information about blood sugar levels (checking) and thereby increasing exposure to potential hypoglycemia. Access to information was reduced in graduated increments, with the parents setting criteria to levels at which they were willing to ...

  10. Measurement of tissue optical properties with optical coherence tomography: Implication for noninvasive blood glucose concentration monitoring

    Science.gov (United States)

    Larin, Kirill V.

    Approximately 14 million people in the USA and more than 140 million people worldwide suffer from diabetes mellitus. The current glucose sensing technique involves a finger puncture several times a day to obtain a droplet of blood for analysis. There have been enormous efforts by many scientific groups and companies to quantify glucose concentration noninvasively using different optical techniques. However, these techniques face limitations associated with low sensitivity, accuracy, and insufficient specificity of glucose concentrations over a physiological range. Optical coherence tomography (OCT), a new technology, is being applied for noninvasive imaging in tissues with high resolution. OCT utilizes sensitive detection of photons coherently scattered from tissue. The high resolution of this technique allows for exceptionally accurate measurement of tissue scattering from a specific layer of skin compared with other optical techniques and, therefore, may provide noninvasive and continuous monitoring of blood glucose concentration with high accuracy. In this dissertation work I experimentally and theoretically investigate feasibility of noninvasive, real-time, sensitive, and specific monitoring of blood glucose concentration using an OCT-based biosensor. The studies were performed in scattering media with stable optical properties (aqueous suspensions of polystyrene microspheres and milk), animals (New Zealand white rabbits and Yucatan micropigs), and normal subjects (during oral glucose tolerance tests). The results of these studies demonstrated: (1) capability of the OCT technique to detect changes in scattering coefficient with the accuracy of about 1.5%; (2) a sharp and linear decrease of the OCT signal slope in the dermis with the increase of blood glucose concentration; (3) the change in the OCT signal slope measured during bolus glucose injection experiments (characterized by a sharp increase of blood glucose concentration) is higher than that measured in

  11. Ferritin blood test

    Science.gov (United States)

    Serum ferritin level ... The amount of ferritin in the blood (serum ferritin level) is directly related to the amount of iron stored in your body. Iron is important for red blood cell production. Your doctor ...

  12. Blood Culture Test

    Science.gov (United States)

    ... difficult to grow in culture, and additional blood cultures using special nutrient media may be done to try to grow and identify the pathogen . Viruses cannot be detected using blood culture bottles designed to grow bacteria. If the health ...

  13. Hybrid CARS for Non-Invasive Blood Glucose Monitoring

    Science.gov (United States)

    Wang, Xi; Pestov, Dmitry; Zhang, Aihua; Murawski, Robert; Sokolov, Alexei; Welch, George; Laane, Jaan; Scully, Marlan

    2007-10-01

    We develop a spectroscopy technique that combines the advantages of both the frequency-resolved coherent anti-Stokes Raman scattering (CARS) and the time-resolved CARS. We use broadband preparation pulses to get an instantaneous coherent excitation of multiplex molecular vibration levels and subsequent optically shaped time-delayed narrowband probing pulse to detect these vibrations. This technique can suppress the nonresonant background and retrieve the molecular fingerprint signal efficiently and rapidly. We employ this technique to glucose detection, the final goal of which is accurate, non-invasive (i.e. painless) and continuous monitoring of blood glucose concentration in the Diabetes diagnosis to replace the current glucose measurement process, which requires painful fingerpricks and therefore cannot be performed more than a few times a day. We have gotten the CARS spectra of glucose aqueous solution down to 2 mM.

  14. Predictors of Daily Blood Glucose Monitoring in Appalachian Ohio

    Science.gov (United States)

    Raffle, Holly; Ware, Lezlee J.; Ruhil, Anirudh V. S.; Hamel-Lambert, Jane; Denham, Sharon A.

    2012-01-01

    Objective: To determine factors contributing to successful diabetes self-management in Appalachia, as evidenced by daily blood glucose monitoring. Methods: A telephone survey (N = 3841) was conducted to assess health status and health care access. The current investigation is limited to the subset of this sample who report having diabetes (N =…

  15. Dynamical Analysis in the Mathematical Modelling of Human Blood Glucose

    Science.gov (United States)

    Bae, Saebyok; Kang, Byungmin

    2012-01-01

    We want to apply the geometrical method to a dynamical system of human blood glucose. Due to the educational importance of model building, we show a relatively general modelling process using observational facts. Next, two models of some concrete forms are analysed in the phase plane by means of linear stability, phase portrait and vector…

  16. Splanchnic blood flow and hepatic glucose production in exercising humans

    DEFF Research Database (Denmark)

    Bergeron, R; Kjaer, M; Simonsen, L;

    2001-01-01

    The study examined the implication of the renin-angiotensin system (RAS) in regulation of splanchnic blood flow and glucose production in exercising humans. Subjects cycled for 40 min at 50% maximal O(2) consumption (VO(2 max)) followed by 30 min at 70% VO(2 max) either with [angiotensin...

  17. 21 CFR 862.1340 - Urinary glucose (nonquantitative) test system.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Urinary glucose (nonquantitative) test system. 862... Test Systems § 862.1340 Urinary glucose (nonquantitative) test system. (a) Identification. A urinary glucose (nonquantitative) test system is a device intended to measure glucosuria (glucose in...

  18. System accuracy of blood glucose monitoring systems: impact of use by patients and ambient conditions.

    Science.gov (United States)

    Schmid, Christina; Haug, Cornelia; Heinemann, Lutz; Freckmann, Guido

    2013-10-01

    For self-monitoring of blood glucose by people with diabetes, the reliability of the measured blood glucose values is a prerequisite in order to ensure correct therapeutic decisions. Requirements for system accuracy are defined by the International Organization for Standardization (ISO) in the standard EN ISO 15197:2003. However, even a system with high analytical quality is not a guarantee for accurate and reliable measurement results. Under routine life conditions, blood glucose measurement results are affected by several factors. First, the act of performing measurements as well as the handling of the system may entail numerous possible error sources, such as traces of glucose-containing products on the fingertips, the use of deteriorated test strips, or the incorrect storage of test strips. Second, ambient and sampling conditions such as high altitude, partial pressure of oxygen, ambient temperature, and the use of alternate test sites can have an influence on measurement results. Therefore, the user-friendliness of a system and the quality of the manufacturer's labeling to reduce the risk of handling errors are also important aspects in ensuring reliable and accurate measurement results. In addition, the analytical performance of systems should be less prone to user errors and ambient conditions. Finally, people with diabetes must be aware of the information and instructions in the manufacturer's labeling and must be able to measure and interpret blood glucose results correctly. PMID:23883407

  19. Electroacupuncture for control of blood glucose in diabetes: literature review.

    Science.gov (United States)

    Peplow, Philip V; Baxter, G David

    2012-02-01

    Electrical stimulation at acupuncture points (acupoints) has been investigated for its utility in lowering blood glucose in hyperglycemic humans and animal models. Only two studies were found using electroacupuncture in human subjects, and in both of these, the participants were normal (nondiabetic) and electrical stimulation was carried out at several acupoints. It had a hypoglycemic effect in obese women with calorific restriction diet using electrical stimulation of 2 Hz for 30 minutes/day for 20 days, but no change occurred in blood glucose of fasted patients in the other study using 1 Hz for 15 minutes. Fourteen animal studies were found, of which, 11 were performed in diabetic and normal rats. A hypoglycemic effect was observed in fasted type 1 diabetic rats using the Zusanli (ST36) leg acupoint with electrical stimulation of 15 Hz for 30 minutes and 60 minutes. In fasted type 2 diabetic rats, blood glucose was lowered using the Zusanli acupoint with electrical stimulation parameters of 15 Hz and 10 mA for 30 minutes. Also, using the Zhongwan (CV12) abdomen acupoint with electrical stimulation parameters of 15 Hz and 10 mA for 90 minutes had a hypoglycemic effect in fasted type 2 diabetic rats. In fasted normal rats, electrical stimulation of 2 Hz or 15 Hz for 30 minutes at the Zusanli or Zhongwan acupoint caused a decrease in blood glucose. Future studies are required in fasted diabetic rats to determine the effect of electroacupuncture on blood levels of insulin, lipids, fatty acids and β-endorphin, and blood flow and nerve conduction velocity. Studies with fasted normal and diabetic human subjects treated by electroacupuncture are warranted using data from animal experiments to inform such studies. PMID:22309901

  20. Study on the accuracy and application values of point-of-care testing of capillary blood glucose andglycosy lated haemoglobin%床旁检测血糖和HbAlc的准确性及其应用价值

    Institute of Scientific and Technical Information of China (English)

    余文辉; 周小梅; 李伟雄; 张书楠

    2008-01-01

    Objective To assess the accuracy and application values of point-of-care testing (POCT) of capillary blood glucose and glyeosylated haemoglobin(Hbalc) levels.Methods 152 residents (aged 21~75 years)were recruited.who had POCT glucose measurements in October 2006.Eighty-eight cases with POCT glucose level≥5.0 mmol/L,or self-reported diabetes mellitus(DM).Thereafter,88 cases had POCT HbAlc and laboratory glucose and HbAlc measurements,respectively.The POCT and laboratory measurements of glucose and HbAlc were compared,and the correlation coefficient r,mean difference and limits of agreement (LOA) between capillary POCT and venous blood laboratory measurements of glucose and HbAlc were evaluated for cross-sectional study.Results Mean and median POCT capillary glucose levels were 7.99 mmol/L and 6.25 mmol/L,respectively,while mean and median laboratory venous plasma glucose concentrations were 7.63 mmol/L and 5.35 mmol/L.Mean and median of POCT capillary HbAlc and laboratory HbAlc were 6.98% and 5.96%,and those of laboratory HbAlc were 7.06%and 6.O%,respectively.The correlation coefficient r for POCT and laboratory results was 0.98 for glucose and 0.95 for HbAlc.The mean difference in results was 0.36 mmol/L for glucose(95% CI:0.13~0.62;LOA:-2.07~2.79 mmol/L,P=0.007) and 0.02% for HbAlc(95%CI:-0.07%~0.09%;LOA:-O.66%~0.68%;P=0.95),respectively. Conclusion POCT capillary HoAle testing offers an accurate,practical and convenient way of monitoring the therapy effects of diabetes in community.While POCT capillary glucose results should be calibrated regularly by a laboratory test of venous plasma,it couldh't be directly used to diagnos DM.%目的 评价床旁检测(POCT)血糖和糖化血红蛋白(HbAlc)的准确性及其应用价值.方法 对88例疑似糖尿病者行POCT方法测定HbAlc和实验室方法测定血浆血糖及HbAlc.将POCT方法测定毛细血管血糖及HbAlc的结果与相应静脉血的实验室测定结果作比较,评估POCT与实验室

  1. Noninvasive biosensor and wireless interrogating system for glucose in blood

    Science.gov (United States)

    Varadan, Vijay K.; Whitchurch, Ashwin K.; Sarukesi, K.

    2003-07-01

    Hypoglycemia-abnormal decrease in blood sugar-is a major obstacle in the management of diabetes and prevention of long-term complications, and it may impose serious effects on the brain, including impairment of memory and other cognitive functions. This paper presents the development of a non-invasive sensor with miniaturized telemetry device in a wrist-watch for monitoring glucose concentration in blood. The sensor concept is based on optical chirality of glucose level in the interstitial fluid. The wrist watch consists of a laser power source of the wavelength compatible with the glucose. A nanofilm with specific chirality is placed at the bottom of the watch. The light then passes through the film and illuminates a small area on the skin. It has been documented that there is certain concentration of sugar level is taken by the intertitial fluid from the blood stream and deposit a portion of it at the dead skin. The wrist-watch when in contact with the outer skin of the human will thus monitor the glucose concentration. A wireless monitoring system in the watch then downloads the data from the watch to a Palm or a laptop computer.

  2. Testing the Glucose Hypothesis among Capuchin Monkeys: Does Glucose Boost Self-Control?

    Science.gov (United States)

    Parrish, Audrey E.; Emerson, Ishara D.; Rossettie, Mattea S.; Beran, Michael J.

    2016-01-01

    The ego-depletion hypothesis states that self-control diminishes over time and with exertion. Accordingly, the glucose hypothesis attributes this depletion of self-control resources to decreases in blood glucose levels. Research has led to mixed findings among humans and nonhuman animals, with limited evidence for such a link between glucose and self-control among closely-related nonhuman primate species, but some evidence from more distantly related species (e.g., honeybees and dogs). We tested this hypothesis in capuchin monkeys by manipulating the sugar content of a calorie-matched breakfast meal following a nocturnal fast, and then presenting each monkey with the accumulation self-control task. Monkeys were presented with food items one-by-one until the subject retrieved and ate the accumulating items, which required continual inhibition of food retrieval in the face of an increasingly desirable reward. Results indicated no relationship between self-control performance on the accumulation task and glucose ingestion levels following a fast. These results do not provide support for the glucose hypothesis of self-control among capuchin monkeys within the presented paradigm. Further research assessing self-control and its physiological correlates among closely- and distantly-related species is warranted to shed light on the mechanisms underlying self-control behavior. PMID:27527225

  3. Blood Test: Lead (For Parents)

    Science.gov (United States)

    ... Things to Know About Zika & Pregnancy Blood Test: Lead KidsHealth > For Parents > Blood Test: Lead Print A A A Text Size What's in ... Análisis de sangre: plomo What It Is A lead test is used to determine the amount of ...

  4. Glucose tolerance, blood lipid, insulin and glucagon concentration after single or continuous administration of aspartame in diabetics.

    Science.gov (United States)

    Okuno, G; Kawakami, F; Tako, H; Kashihara, T; Shibamoto, S; Yamazaki, T; Yamamoto, K; Saeki, M

    1986-04-01

    A nutritive sweetener, aspartame (L-aspartyl-L-phenylalanine methylester) was administered orally to normal controls and diabetic patients in order to evaluate effects on blood glucose, lipids and pancreatic hormone secretion. An oral glucose tolerance test was also performed in the same subjects as a control study of aspartame administration. In 7 normal controls and 22 untreated diabetics, a single dose of 500 mg aspartame, equivalent to 100 g glucose in sweetness, induced no increase in blood glucose concentration. Rather, a small but significant decrease in blood glucose was noticed 2 or 3 h after administration. The decrease in blood glucose was found to be smallest in the control and became greater as the diabetes increased in severity. No significant change in blood insulin or glucagon concentration during a 3-h period was observed in either the controls or the diabetics. The second study was designed to determine the effects of 2 weeks' continuous administration of 125 mg aspartame, equal in sweetness to the mean daily consumption of sugar (20-30 g) in Japan, to 9 hospitalized diabetics with steady-state glycemic control. The glucose tolerance showed no significant change after 2 weeks' administration. Fasting, 1 h and 2 h postprandial blood glucose, blood cholesterol, triglyceride and HDL-cholesterol were also unaffected. From these and other published results, aspartame would seem to be a useful alternative nutrient sweetener for patients with diabetes mellitus. PMID:3522147

  5. Patterns of self-monitoring of blood glucose in insulin-treated diabetes: analysis of a Scottish population over time.

    Science.gov (United States)

    Cameron, D; Harris, F M; Evans, J M M

    2016-07-01

    Analysis of a diabetes clinical information system in Tayside, Scotland, shows that a significant proportion of insulin-treated patients with diabetes are not self-monitoring blood glucose according to current clinical guidance and recommendations, with some not self-monitoring their blood glucose at all. Although there has been an increase in the number of reagent strips dispensed over the past decade, this increase is mainly accounted for by increased testing frequency among people with diabetes already testing. PMID:26990502

  6. Visual detection of blood glucose based on peroxidase-like activity of WS2 nanosheets.

    Science.gov (United States)

    Lin, Tianran; Zhong, Liangshuang; Song, Zhiping; Guo, Liangqia; Wu, Hanyin; Guo, Qingquan; Chen, Ying; Fu, FengFu; Chen, Guonan

    2014-12-15

    Tungsten disulfide (WS2) nanosheets were discovered to possess intrinsic peroxidase-like activity and catalyze the peroxidase substrate 3,3',5,5'-tetramethylbenzidine (TMB) to produce a color reaction in the presence of H2O2. Based on this finding, a colorimetric method and a portable test kit for the visual detection of blood glucose have been developed by using glucose oxidase (GOx) and WS2 nanosheets-catalyzed reactions. The linear range for glucose was ranged from 5 to 300 μM (R(2)=0.999) with the detection limit of 2.9 μM. The portable test kit was successfully evaluated glucose levels in serum samples from normal persons and diabetes persons by the observable color change from pale yellow to yellow-green, blue-green. PMID:25032681

  7. Feasibility of non-invasive optical blood-glucose detection using overtone circular dichroism

    CERN Document Server

    Hokr, Brett H; Meng, Zhaokai; Petrov, Georgi I; Yakovlev, Vladislav V

    2016-01-01

    Diabetes is one of the most debilitating and costly diseases currently plaguing humanity. It is a leading cause of death and dismemberment in the world, and we know how to treat it. Accurate, continuous monitoring and control of blood glucose levels via insulin treatments are widely known to mitigate the majority of detrimental effects caused by the disease. The primary limitation of continuous glucose monitoring is patient non-compliance due to the unpleasant nature of "finger-stick" testing methods. This limitation can be largely, or even completely, removed by non-invasive testing methods. In this report, we demonstrate the vibrational overtone circular dichroism properties of glucose and analyze its use as a method of non-invasive glucose monitoring, capable of assuaging this trillion dollar scourge.

  8. Perioperative control of blood glucose level in cardiac surgery.

    OpenAIRE

    Minakata, Kenji; Sakata, Ryuzo

    2013-01-01

    It is well recognized that poor perioperative blood glucose (BG) control can increase the risk of infection, cardiovascular accidents, and even death in patients undergoing cardiac surgery. Since it has been reported that tight BG control (80-110 mg/dL) yields better outcomes in critically ill patients, it became a standard of care to control BG using intravenous insulin infusion in ICU. However, it has been debated in terms of the optimal target range whether a strict control with intensive ...

  9. Influence of Artificial Sweetener on Human Blood Glucose Concentration

    OpenAIRE

    Ilse Skokan; P. Christian Endler; Beatrix Wulkersdorfer; Dieter Magometschnigg; Heinz Spranger

    2007-01-01

    Artificial sweeteners, such as saccharin or cyclamic acid are synthetically manufactured sweetenings. Known for their low energetic value they serve especially diabetic and adipose patients as sugar substitutes. It has been hypothesized that the substitution of sugar with artificial sweeteners may induce a decrease of the blood glucose. The aim of this study was to determine the reliability of this hypothesis by comparing the influence of regular table sugar and artificial sweeteners on the b...

  10. Inhaled insulin for controlling blood glucose in patients with diabetes

    OpenAIRE

    Silverman, Bernard L; Barnes, Christopher J.; Campaigne, Barbara N.; Muchmore, Douglas B.

    2007-01-01

    Diabetes mellitus is a significant worldwide health problem, with the incidence of type 2 diabetes increasing at alarming rates. Insulin resistance and dysregulated blood glucose control are established risk factors for microvascular complications and cardiovascular disease. Despite the recognition of diabetes as a major health issue and the availability of a growing number of medications designed to counteract its detrimental effects, real and perceived barriers remain that prevent patients ...

  11. Correlation between macrosomia body indices and maternal fasting blood glucose.

    Science.gov (United States)

    Song, Y; Zhang, S; Song, W

    2014-05-01

    To explore the significance of neonatal body indices in identifying pathological macrosomia, we implemented a retrospective study of 254 neonates, including: 100 macrosomia of diabetic pregnancies, 77 macrosomia of healthy pregnancies and 77 normal neonates of healthy pregnancies, using their birth weight, body length, head circumference and chest circumference, to calculate neonatal body indices, multiple regression analysis of the correlation between newborn body indices and maternal fasting blood glucose. The Quetelet Index and Kaup Index of diabetic macrosomia is higher than that of non-diabetic macrosomia; HC:CC (ratio between head circumference and chest circumference) is reversed (p body indices to maternal fasting blood glucose is BG = 6.959 + 0.031 QI -4.482 × HC:CC. Quetelet index and HC:CC have linear relationship with maternal fasting blood glucose (p weight, Quetelet Index and HC:CC could better reflect the effect of maternal metabolism on the fetus and be of great significance in the prediction of fetal macrosomia. PMID:24798112

  12. Effect of training on the performance of blood glucose monitoring using a reagent strip (Glucoprofil).

    Science.gov (United States)

    Chantelau, E; Starostina, E G; Antsiferov, M B

    1990-11-01

    A relatively simple, new test-strip for blood-glucose monitoring, the Glucoprofil strip with a reaction-zone of film-foil, was evaluated by testing 100 different blood glucose concentrations between 2.1 and 29.7 mmol/l. The results were obtained visually before and after training to read the color changes of the strip according to the scale on the strip-container. Plasma glucose measurements with the Beckman Glucose-Analyzer were used for reference. The results show that the Glucoprofil-strip readings correlated well with the reference method (r = 0.97), thorough training provided. The mean deviation of the strip results was less than 1 mmol/l. Similar results were obtained using another blood glucose strip, the Haemoglukotest 20-800 R. Our study indicates that the performance of the Glucoprofil strip is satisfactory, and hence the strip may be useful for clinical purposes. Consistent with previous reports we could demonstrate that training improved the reading results of the Glucoprofil strip.

  13. Impaired first-phase insulin response predicts postprandial blood glucose increment in patients with recently diagnosed type 2 diabetes

    DEFF Research Database (Denmark)

    Gredal, C; Rosenfalck, A M; Dejgaard, Anders;

    2007-01-01

    The aim of the study was to evaluate the relationship between postprandial blood glucose and first-phase insulin response and, furthermore, to assess whether the intravenous glucagon stimulation test can be used as a predictor for increased postprandial glucose in patients with recently diagnosed...... type 2 diabetes....

  14. Estradiol blood test

    Science.gov (United States)

    E2 test ... temporarily stop taking certain medicines that may affect test results. Be sure to tell your provider about ... helps prevent sperm from dying too early. This test may be ordered to check: How well your ...

  15. Blood optical properties at various glucose level values in THz frequency range

    Science.gov (United States)

    Gusev, S. I.; Borovkova, M. A.; Strepitov, M. A.; Khodzitsky, M. K.

    2015-07-01

    The number of diabetics is rapidly growing every day in all parts of the world. By the year 2010, the number of patients suffering from diabetes had amounted to more than 230 million people, which is estimated as 3.5% of the whole world adult population [1]. According to expert forecasts, this number is projected to double by the year 2025, which is going to be 7% of whole Earth population. It was calculated that every 10 seconds someone in the world dies due to diabetes and its complications, which is 3 million people per year. The average life expectancy of children with diabetes is less than 28.3 years of onset. Diabetes is considered to be the fourth most common cause of death in industrialized countries. Vascular complications due to diabetes cause early disability and high mortality. Mortality from heart diseases and strokes is 2-3 times more likely for patients suffering from diabetes, whereas blindness, nephropathy and lower limbs gangrene happen respectively 10, 12-15 times, and almost 20 times more often for diabetics than general population. The number and strength of complications depend directly on the blood glucose level control quality. At the moment, the blood glucose level measurements are performed by glucometers [2,3]. This method requires that a patient makes a finger puncture for every measurement. About five punctures per day should be done for proper glucose monitoring, which is about 1,800 punctures per year. Besides, each measurement by glucometer requires a distinct test strip. Expenses for 1,800 test strips could be estimated as about 450 euros per year. It is also necessary to take into account that each puncture has a risk of blood poisoning. Using non-invasive techniques for glucose level control could reduce the amount of possible risky manipulations by 1800 per year. Moreover, it is worth mentioning that only eight of ten fingers are suitable for puncturing, and the constant skin damage which cannot be avoided is quite annoying for

  16. Molecular Weight Dependent Glucose Lowering Effect of Low Molecular Weight Chitosan Oligosaccharide (GO2KA1 on Postprandial Blood Glucose Level in SD Rats Model

    Directory of Open Access Journals (Sweden)

    Emmanouil Apostolidis

    2013-07-01

    Full Text Available This research investigated the effect of enzymatically digested low molecular weight (MW chitosan oligosaccharide on type 2 diabetes prevention. Three different chitosan oligosaccharide samples with varying MW were evaluated in vitro for inhibition of rat small intestinal α-glucosidase and porcine pancreatic α-amylase (GO2KA1; 10,000 Da. The in vitro results showed that all tested samples had similar rat α-glucosidase inhibitory and porcine α-amylase inhibitory activity. Based on these observations, we decided to further investigate the effect of all three samples at a dose of 0.1 g/kg, on reducing postprandial blood glucose levels in Sprague-Dawley (SD rat model after sucrose loading test. In the animal trial, all tested samples had postprandial blood glucose reduction effect, when compared to control, however GO2KA1 supplementation had the strongest effect. The glucose peak (Cmax for GO2KA1 and control was 152 mg/dL and 193 mg/dL, respectively. The area under the blood glucose-time curve (AUC for GO2KA1 and control was 262 h mg/dL and 305 h mg/dL, respectively. Furthermore, the time of peak plasma concentration of blood glucose (Tmax for GO2KA1 was significantly delayed (0.9 h compared to control (0.5 h. These results suggest that GO2KA1 could have a beneficial effect for blood glucose management relevant to diabetes prevention in normal and pre-diabetic individuals. The suggested mechanism of action is via inhibition of the carbohydrate hydrolysis enzyme α-glucosidase and since GO2KA1 (MW < 1000 Da had higher in vivo effect, we hypothesize that it is more readily absorbed and might exert further biological effect once it is absorbed in the blood stream, relevant to blood glucose management.

  17. Heterogeneity in glucose response curves during an oral glucose tolerance test and associated cardiometabolic risk

    DEFF Research Database (Denmark)

    Hulman, Adam; Simmons, Rebecca Kate; Vistisen, Dorte;

    2016-01-01

    We aimed to examine heterogeneity in glucose response curves during an oral glucose tolerance test with multiple measurements and to compare cardiometabolic risk profiles between identified glucose response curve groups. We analyzed data from 1,267 individuals without diabetes from five studies...... in Denmark, the Netherlands and the USA. Each study included between 5 and 11 measurements at different time points during a 2-h oral glucose tolerance test, resulting in 9,602 plasma glucose measurements. Latent class trajectories with a cubic specification for time were fitted to identify different...... patterns of plasma glucose change during the oral glucose tolerance test. Cardiometabolic risk factor profiles were compared between the identified groups. Using latent class trajectory analysis, five glucose response curves were identified. Despite similar fasting and 2-h values, glucose peaks and peak...

  18. Detection accuracy of three glucose meters estimated by capillary blood glucose measurements compared with venous blood evaluated by the diabetes unit of the Hospital Evangélico de Curitiba, Brazil

    Directory of Open Access Journals (Sweden)

    Camacho SL

    2012-05-01

    Full Text Available Mirnaluci Paulino Ribeiro Gama, Camile Fiorese Cruzeta, Ana Carolina Ossowski, Marina Rech Bay, Mariella Muller Michaelis, Stênio Lujan CamachoEndocrinology and Diabetes Service, Hospital Universitário Evangélico de Curitiba, BrazilObjective: To compare capillary blood glucose measurements between three different glucose meters and with the serum glucose values of inpatients at the diabetes unit of Hospital Universitário Evangélico de Curitiba, Brazil.Materials and methods: A total of 132 non-intensive care unit patients admitted for medical and surgical pathologies were evaluated. All patients reported a previous diagnosis of diabetes mellitus, were under 60 years of age, had no hematocrit alterations, remained hemodynamically stable during the time of data collection, and were given no ascorbic acid, acetaminophen, dopamine, or mannitol during follow-up. Capillary and serum blood glucose samples were collected simultaneously by finger-stick and venipuncture 2 hours after lunch, by the same observer, who was blinded to the serum glucose results. First, between July and November 2009, capillary glucose levels were measured using the blood glucose meters OneTouch SureStep® and MediSense Optium®. Between November 2009 and February 2010, capillary blood glucose levels were measured on the glucose meters OneTouch SureStep and Optium Xceed®. The capillary glucose readings were analyzed between meters and also in relation to the serum blood glucose values by the t-test for paired samples and the Mood two-sample test.Results: The patients’ mean age was 50.45 years. The blood glucose means obtained using the meters OneTouch SureStep, MediSense Optium, and Optium Xceed were, respectively, 183.87 mg/dL, 178.49 mg/dL, and 192.73 mg/dL, and the mean for the serum glucose values was 174.58 mg/dL. A significant difference was found between the capillary measurements taken by the glucose meters and the serum glucose measurements (P < 0.05, and no

  19. Bihormonal control of blood glucose in people with type 1 diabetes

    DEFF Research Database (Denmark)

    Batora, Vladimir; Tárnik, Marían; Murgaš, Ján;

    2015-01-01

    This paper presents a bihormonal artificial pancreas (AP) for people with type 1 diabetes (T1D) designed to provide a safe blood glucose control with minimal use of glucagon. The control algorithm uses insulin as well as glucagon to prevent hyper- and hypoglycemia. We employ a novel prediction...... predicts hypoglycemia. Predictions utilize an ARMAX model describing glucose-insulin and glucose-glucagon dynamics. The model parameters are estimated from basic patient-specific data. A continuous glucose monitor provides feedback. We test the control algorithm using a simulation model with time......-based activation of glucagon administration. The control algorithm consists of a Kalman filter, an insulin infusion model predictive controller (MPC), a proportional-derivative (PD) controller for glucagon infusion, and a meal time insulin bolus calculator. The PD controller is activated if the Kalman filter...

  20. 重症患者床旁即时血糖检测的准确性:葡萄糖氧化酶法和葡萄糖脱氢酶法的评价%Accuracy of point-of-care testing for blood glucose monitoring in critically ill patients:evaluation of glucase oxidase and glucose dehydrogenase methods

    Institute of Scientific and Technical Information of China (English)

    冯涛; 何丽娟; 曹相原; 闫红

    2013-01-01

    Objective To evaluate the accuracy of point-of-care testing (POCT) for blood glucose monitoring in critically ill patients.Methods Two hundred and forty critically ill patients,of both sexes,aged 20-88 yr,with Acute Physiology and Chronic Health Evaluation Ⅱ score of 1-45,were enrolled.The venous,arterial and capillary blood samples were collected to determine the real-time blood glucose level using glucose oxidase (GOD) and glucose dehydrogenase (GDH) methods.The blood glucose level measured by central laboratory hexokinase method simultaneously was served as standard level.Error Grid analysis (EGA) and Bland-Altman analysis were used to determine accuracy and consistency,respectively.The accuracy of real-time blood glucose levels within the consistent limits was evaluated.Results 1.The results of EGA showed that 98.7 %,98.3 %,98.3 %(GDH method) and 96.2%,96.6%,96.7% (GOD method) of the difference between venous,arterial and capillary blood glucose levels measured and the standard level were located in the A and B zones,respectively,and 1.2%,1.7%,1.7% (GDH method) and 2.9%,3.3%,3.3% (GOD method) in the D zone.0.8% (GOD method) of the difference between venous blood glucose levels and the standard level were located in the C zone.2.Bland-Altman analysis showed that the difference between the standard level and glucose level measured in blood samples from the vein,artery and capillary.was-0.1,-0.3,-0.2 mmol/L (GDH method) and-0.9,-1.0,-0.9 mmol/L (GOD method),respectively,and the incidence beyond the upper and lower limits of consistency zone was 4.5 %,6.7 %,6.6 % (GDH method) and 4.6 %,5.0 %,7.1% (GOD method),respectively.The accuracy of venous,arterial and capillary blood glucose levels within the consistent limits was 94.3 %,92.1%,93.7% (GOD method) and 96.6%,95.1%,95.5% (GDH method),respetively.Conclusion The accuracy of POCT for blood glucose monitored by GOD and GDH methods is good in critically ill patients

  1. Association between maternal diet factors and hemoglobin levels, glucose tolerance, blood pressure and gestational age in a Hispanic population.

    Science.gov (United States)

    Soto, Roxana; Guilloty, Natacha; Anzalota, Liza; Rosario, Zaira; Cordero, José F; Palacios, Cristina

    2015-06-01

    The aim of this study was to describe the dietary patterns of pregnant women in northern Puerto Rico and explore associations between diet factors with pregnancy related measurements. This analysis is based on the Puerto Rico Testsite for Exploring Contamination Threats (PROTECT), a prospective cohort that is studying environmental risk factors for preterm births in PR. Participants completed a food frequency questionnaire (FFQ) around 20-28 weeks of gestation. The following pregnancy related measures were collected from the medical records: hemoglobin, blood glucose, blood pressure and gestational age. Potential associations between diet factors and pregnancy measures were assessed using chi square analysis with SPSS. A total of 180 participants completed the FFQ; low hemoglobin levels was found in 19.2%, high blood glucose levels was found in 21.1% by fasting blood glucose test and 24.6%by 1-hour 50 g oral glucose screening test, high blood pressure was found in 2.9% (systolic) and 6.5% (diastolic), and pre-term birth was found in 10.4% of the participants. High consumption of rice, desserts and sweets was associated with higher levels of fasting blood glucose levels (p desserts, can lead to high levels of blood glucose and can be a potential predictor of other pregnancy complications during pregnancy in these study participants, such as gestational diabetes. PMID:26817380

  2. Assessment of Self-Monitored Blood Glucose Results Using a Reflectance Meter with Memory and Microcomputer

    OpenAIRE

    Kuykendall, V.G.; Michaels, D W; Hartmann, K.G.

    1985-01-01

    A microcomputer software package for diabetes patient care utilizing self-monitoring of blood glucose (SMBG) has been developed. The software facilitates the collection, storage, analysis, and presentation of blood glucose/time information. Data entry is accomplished automatically via interface to hand held blood glucose reflectance instruments which retain up to 339 glucose/time results in internal RAM. The times of other significant clinical events may also be stored in the meter and upload...

  3. Capillary Bedside Blood Glucose Measurement in Neonates: Missing a Diagnosis of Galactosemia

    OpenAIRE

    Özbek, Mehmet Nuri; Öcal, Murat; Tanrıverdi, Sibel; Baysal, Birsen; Deniz, Ahmet; Öncel, Kahraman; Demirbilek, Hüseyin

    2015-01-01

    A number of factors may lead to inaccuracy in measurement of capillary blood glucose with a glucometer. Measurement of other carbohydrate molecules such as galactose and fructose along with glucose can potentially be a cause of error. We report a newborn patient who was referred to our hospital with conjugated bilirubinemia, hepatomegaly and high capillary blood glucose levels measured with a glucometer. Simultaneous biochemical measurements revealed normal blood glucose levels. Further inves...

  4. Detection of protein biomarker using a blood glucose meter.

    Science.gov (United States)

    Lan, Tian; Xiang, Yu; Lu, Yi

    2015-01-01

    mHeath technologies are recognized to play important roles in the future of personal care and medicine. However, their full potentials have not been reached, as most of current technologies are restricted to monitoring physical and behavioral parameters, such as body temperature, heart rate, blood pressure, and physical movement, while direct monitoring of biomarkers in body fluids can provide much more accurate and useful information for medical diagnostics. A major barrier to realizing the full potential of mHealth is the high costs and long cycles of developing mHealth devices capable of monitoring biomarkers in body fluids. To lower the costs and shorten the developmental cycle, we have demonstrated the leveraging of the most successful portable medical monitoring device on the market, the blood glucose meter (BGM), with FDA-approved smartphone technologies that allow for wireless transmission and remote monitoring of a wide range of non-glucose targets. In this protocol, an aptamer-based assay for quantification of interferon-γ (IFN-γ) using an off-the-shelf BGM is described. In this assay, an aptamer-based target recognition system is employed. When IFN-γ binds to the aptamer, it triggers the release of a reporter enzyme, invertase, which can catalyze the conversion of sucrose (not detected by BGM) to glucose. The glucose being produced is then detected using a BGM. The system mimics a competitive enzyme-linked immunosorbent assay (ELISA), where the traditional immunoassay is replaced by an aptamer binding assay; the reporter protein is replaced by invertase, and finally the optical or fluorescence detector is replaced with widely available BGMs. PMID:25626534

  5. Aldosterone blood test

    Science.gov (United States)

    ... Pregnancy High- or low-sodium diet Strenuous exercise Stress How the Test will Feel When the needle is inserted to ... pressure. Aldosterone increases the reabsorption of sodium and water and the release of potassium in the kidneys. ...

  6. Parathyroid hormone (PTH) blood test

    Science.gov (United States)

    ... not produce enough PTH ( hypoparathyroidism ) Low levels of magnesium in the blood Radiation to the parathyroid glands Sarcoidosis Excess vitamin D intake Other conditions for which the test may be ...

  7. Effect of Intravenous Glucose Tolerance Test on Bone Turnover Markers in Adults with Normal Glucose Tolerance

    Science.gov (United States)

    Xiang, Shou-Kui; Wan, Jing-Bo; Jiang, Xiao-Hong; Zhu, Yong-Hua; Ma, Jin-Hong; Hua, Fei

    2016-01-01

    Background It is well known that enteral nutrients result in acute suppression of bone turnover markers (BTMs), and incretin hormones are believed to play a significant role in this physiological skeletal response. However, there is limited research exploring the impact of parenteral nutrients on BTMs. Our aim was to assess the influence of intravenous glucose on BTMs in adults with normal glucose tolerance (NGT). Material/Methods We conducted 1-h intravenous glucose tolerance test (IVGTT) in 24 subjects with NGT. Blood samples were collected before and 5, 10, 15, 20, 30, 60 min after administration of glucose, then serum levels of bone formation marker procollagen type I N-terminal propeptide (P1NP) and resorption marker C-terminal cross-linking telopeptides of collagen type I (CTX) were measured. Results During IVGTT, the fasting CTX level fell gradually and reached a nadir of 80.4% of the basal value at 60 min. Conversely, the fasting P1NP level decreased mildly and reached a nadir of 90.6% of the basal value at 15 min, then gradually increased and reached 96.6% at 60 min. The CTX-to-P1NP ratio increased slightly and reached a peak of 104.3% of the basal value at 10 min, then fell gradually and reached a nadir of 83% at 60 min. Conclusions Our study indicates that intravenous glucose results in an acute suppression of BTMs in the absence of incretin hormones. The mechanism responsible for this needs further investigation. PMID:27447783

  8. Effect of guar crispbread with cereal products and leguminous seeds on blood glucose concentrations of diabetics.

    OpenAIRE

    Jenkins, D J; Wolever, T M; Taylor, R H; Barker, H M; Fielden, H; Jenkins, A. L.

    1980-01-01

    To compare the effect on blood glucose concentrations of guar incorporated into crispbreads with that of unprocessed high-fibre foods groups of four to six diabetics took a total of seven test breakfasts on separate days. By comparison with a breakfast of wholemeal bread and cheese, guar crispbread combined with bread reduced the area under the glucose response curve to 51% (p < 0.05); bread and soya beans reduced the area to 65% (p < 0.05); guar crispbread with soya beans to 25% (p < 0.002);...

  9. Tracking blood glucose and predicting prediabetes in Chinese children and adolescents: a prospective twin study.

    Directory of Open Access Journals (Sweden)

    Guoying Wang

    Full Text Available We examined the tracking of blood glucose, the development of prediabetes, and estimated their genetic contributions in a prospective, healthy, rural Chinese twin cohort. This report includes 1,766 subjects (998 males, 768 females aged 6-21 years at baseline who completed a 6-year follow-up study. Oral glucose tolerance test was performed for all subjects at both baseline and follow-up. We found that subjects with low fasting plasma glucose (FPG or 2 h post-load glucose (PG levels at baseline tended to remain at the low level at follow-up. Subjects in the top tertile of baseline plasma glucose tended to have a higher risk of developing prediabetes at follow-up compared to the low tertile: in males, 37.6% vs. 27.6% for FPG and 37.2% vs. 25.7% for 2hPG, respectively; in females, 31.0% vs. 15.4% for FPG and 28.9% vs. 15.1% for 2 h PG, respectively. Genetic factors explained 43% and 41% of the variance of FPG, and 72% and 47% for impaired fasting glucose for males and females, respectively; environmental factors substantially contribute to 2hPG status and impaired glucose tolerance. In conclusion, in this cohort of healthy rural Chinese children and adolescents, we demonstrated that both FPG and 2hPG tracked well and was a strong predictor of prediabetes. The high proportion of children with top tertile of blood glucose progressed to prediabetes, and the incidence of prediabetes has a male predominance. Genetic factors play more important role in fasting than postload status, most of which was explained by unique environmental factors.

  10. Capillary bedside blood glucose measurement in neonates: missing a diagnosis of galactosemia.

    Science.gov (United States)

    Özbek, Mehmet Nuri; Öcal, Murat; Tanrıverdi, Sibel; Baysal, Birsen; Deniz, Ahmet; Öncel, Kahraman; Demirbilek, Hüseyin

    2015-03-01

    A number of factors may lead to inaccuracy in measurement of capillary blood glucose with a glucometer. Measurement of other carbohydrate molecules such as galactose and fructose along with glucose can potentially be a cause of error. We report a newborn patient who was referred to our hospital with conjugated bilirubinemia, hepatomegaly and high capillary blood glucose levels measured with a glucometer. Simultaneous biochemical measurements revealed normal blood glucose levels. Further investigation led to a diagnosis of classical galactosemia. Capillary blood glucose level measured with glucometer also dropped to normal values following cessation of breastfeeding and initiation of feeding with a lactose-free formula. PMID:25800483

  11. Comparative analysis of blood glucose between point-of-care testing bedside glucometer and biochemistry analyzer%即时检验床旁血糖仪与生物化学静脉血糖仪对比分析

    Institute of Scientific and Technical Information of China (English)

    谌海兰; 毕小云

    2016-01-01

    目的:分析监测血糖的即时检验(POCT)床旁血糖仪与检验科大型生物化学分析仪(简称生化分析仪)检测结果,以监测临床正在使用的POCT床旁血糖仪是否符合国家卫生和计划生育委员会(简称卫计委)相关使用要求。方法选择重庆医科大学附属第一医院POCT床旁血糖仪(罗氏卓越和强生稳步)和生化分析血糖仪(罗氏Modular-DDPP模块检测仪),对静脉血分别检测全血血糖浓度和血浆血糖浓度,每台血糖分析仪检测50份标本。对比检测标本的偏倚是否符合卫计委的要求,当血糖浓度<4.2 mmol/L时,至少95%的检测结果误差应在±0.83 mmol/L的范围内;当血糖浓度≥4.2 mmol/L时,至少95%的检测结果误差应在±20%范围内。结果笔者所在医院36个科室151台POCT床旁血糖仪检测结果与生化分析仪检测结果对比,有2个指标超过比对要求的最高限,不达标,应进行更换。 POCT床旁血糖仪达标率为98.67%。结论血糖仪在使用过程中存在损耗,应根据卫计委相关要求定期与生化分析仪检测结果进行对比,对于对比不达标的血糖仪应进行校准或更换,并应与生化分析仪检测结果进行对比,对比合格后方可用于临床患者自我监测。%Objective To study the blood glucose testing results of point-of-care testing(POCT) bedside glucometers and large biochemical analyzers (biochemical analyzer) in Clinical Laboratory Department, and determine whether the clinically used bed-side POCT meet the requirement of National Health and Family Planning Commission (NHFPC) of PRC. Methods The POCT bedside glucometer (Accu-Chek Performa of Roche and Sure-step of Johnson & Johnson) and biochemical analyzer (Modular-DDPP module detector of Roche) in First Affiliated Hospital of Chongqing Medical University (CQMU) were used to measure the venous plasma glucose concentration in whole blood and plasma glucose, each

  12. Effect of repaglinide on endothelial dysfunction during a glucose tolerance test in subjects with impaired glucose tolerance

    Directory of Open Access Journals (Sweden)

    Wascher Thomas C

    2006-04-01

    Full Text Available Abstract Background Impaired glucose tolerance (IGT is associated with increased cardiovascular risk. The pathophysiological mechanisms linking post-challenge hyperglycemia to accelerated atherosclerosis, however remain to be elucidated. Methods A prospective, open, randomised, cross-over study was performed to investigate the effect of 2 mg repaglinide on hyperglycemia and endothelial function during an oral glucose tolerance test (75 g glucose in 12 subjects with diagnosed IGT. Blood samples for determination of plasma glucose were drawn fasting, 1 and 2 hours after glucose ingestion. Endothelial function was assessed by measuring flow-mediated dilatation (FMD of the brachial artery with high-resolution ultrasound. Results Administration of repaglinide resulted in a significant reduction of plasma glucose at 2 hours (172.8+/-48.4 vs. 138.3+/-41.2 mg/dl; p Conclusion In subjects with IGT, the endothelial dysfunction observed after a glucose challenge is related to the extent of hyperglycemia. Reduction of hyperglycemia by repaglinide reduces endothelial dysfunction in a glucose dependent manner.

  13. Value of oral glucose tolerance test in the acute phase of myocardial infarction

    Directory of Open Access Journals (Sweden)

    Grabczewska Zofia

    2011-03-01

    Full Text Available Abstract Background Although European guidelines advise oral glucose tolerance test (OGTT in patients with acute myocardial infarction (AMI before or shortly after hospital discharge, data supporting this recommendation are inconclusive. We aimed to analyze whether disturbances in glucose metabolism diagnosed before hospital discharge in AMI patients represents a latent pre-existing condition or rather temporary finding. Additionally, we planned to investigate the value of pre-selected glycemic control parameters as predictors of long-term glucometabolic state. Methods We assessed admission glycemia, glycated hemoglobin, mean blood glucose concentration on days 1 and 2 in 200 patients with a first AMI but without overt disturbances of glucose metabolism. We also performed OGTT at discharge and 3 months after discharge. Results The prevalence of disturbances in glucose metabolism (as assessed by OGTT at 3 months was significantly lower than at discharge (29% vs. 48%, p = 0.0001. Disturbances in glucose metabolism were not confirmed in 63% of patients with impaired glucose tolerance and in 36% of patients with diabetes mellitus diagnosed during the acute phase of AMI. Age >77 years, glucose ≥12.06 mmol/l at 120 minutes during OGTT before discharge and mean blood glucose level on day 2 >7.5 mmol/l were identified as independent predictors of disturbances in glucose metabolism at the 3-month follow-up. Conclusions Disturbances in glucose metabolism observed in patients with a first AMI are predominantly transient. Elderly age, high plasma glucose concentration at 120 minutes during OGTT at discharge and elevated mean blood glucose level on day 2 were associated with sustained disturbances in glucose metabolism.

  14. Performance Evaluation and Labeling Comprehension of a New Blood Glucose Monitoring System with Integrated Information Management

    Science.gov (United States)

    List, Susan M; Starks, Nykole; Baum, John; Greene, Carmine; Pardo, Scott; Parkes, Joan L; Schachner, Holly C; Cuddihy, Robert

    2011-01-01

    Background This study evaluated performance and product labeling of CONTOUR® USB, a new blood glucose monitoring system (BGMS) with integrated diabetes management software and a universal serial bus (USB) port, in the hands of untrained lay users and health care professionals (HCPs). Method Subjects and HCPs tested subject's finger stick capillary blood in parallel using CONTOUR USB meters; deep finger stick blood was tested on a Yellow Springs Instruments (YSI) glucose analyzer for reference. Duplicate results by both subjects and HCPs were obtained to assess system precision. System accuracy was assessed according to International Organization for Standardization (ISO) 15197:2003 guidelines [within ±15 mg/dl of mean YSI results (samples <75 mg/dl) and ±20% (samples ≥75 mg/dl)]. Clinical accuracy was determined by Parkes error grid analysis. Subject labeling comprehension was assessed by HCP ratings of subject proficiency. Key system features and ease-of-use were evaluated by subject questionnaires. Results All subjects who completed the study (N = 74) successfully performed blood glucose measurements, connected the meter to a laptop computer, and used key features of the system. The system was accurate; 98.6% (146/148) of subject results and 96.6% (143/148) of HCP results exceeded ISO 15197:2003 criteria. All subject and HCP results were clinically accurate (97.3%; zone A) or associated with benign errors (2.7%; zone B). The majority of subjects rated features of the BGMS as “very good” or “excellent.” Conclusions CONTOUR USB exceeded ISO 15197:2003 system performance criteria in the hands of untrained lay users. Subjects understood the product labeling, found the system easy to use, and successfully performed blood glucose testing. PMID:22027308

  15. Frequency and motives of blood glucose self-monitoring in type 1 diabetes

    DEFF Research Database (Denmark)

    Hansen, M V; Pedersen-Bjergaard, U; Heller, S R;

    2009-01-01

    AIMS: Recommendations for self-monitoring of blood glucose (SMBG) from the DCCT have not been implemented with the same rigour as recommendations for intensifying insulin therapy. We assessed the frequency of and motives for SMBG and compared SMBG behaviour with clinical, behavioural and demograp......AIMS: Recommendations for self-monitoring of blood glucose (SMBG) from the DCCT have not been implemented with the same rigour as recommendations for intensifying insulin therapy. We assessed the frequency of and motives for SMBG and compared SMBG behaviour with clinical, behavioural and...... hypoglycaemia and awareness of hypoglycaemia were independently associated with testing behaviour, whereas the presence of late diabetic complications was not. Lower HbA1c was associated with more frequent testing. CONCLUSION: Patient compliance regarding SMBG is limited. Thus, almost two thirds of the patients...

  16. New Criteria for Assessing the Accuracy of Blood Glucose Monitors meeting, October 28, 2011.

    Science.gov (United States)

    Walsh, John; Roberts, Ruth; Vigersky, Robert A; Schwartz, Frank

    2012-03-01

    Glucose meters (GMs) are routinely used for self-monitoring of blood glucose by patients and for point-of-care glucose monitoring by health care providers in outpatient and inpatient settings. Although widely assumed to be accurate, numerous reports of inaccuracies with resulting morbidity and mortality have been noted. Insulin dosing errors based on inaccurate GMs are most critical. On October 28, 2011, the Diabetes Technology Society invited 45 diabetes technology clinicians who were attending the 2011 Diabetes Technology Meeting to participate in a closed-door meeting entitled New Criteria for Assessing the Accuracy of Blood Glucose Monitors. This report reflects the opinions of most of the attendees of that meeting. The Food and Drug Administration (FDA), the public, and several medical societies are currently in dialogue to establish a new standard for GM accuracy. This update to the FDA standard is driven by improved meter accuracy, technological advances (pumps, bolus calculators, continuous glucose monitors, and insulin pens), reports of hospital and outpatient deaths, consumer complaints about inaccuracy, and research studies showing that several approved GMs failed to meet FDA or International Organization for Standardization standards in postapproval testing. These circumstances mandate a set of new GM standards that appropriately match the GMs' analytical accuracy to the clinical accuracy required for their intended use, as well as ensuring their ongoing accuracy following approval. The attendees of the New Criteria for Assessing the Accuracy of Blood Glucose Monitors meeting proposed a graduated standard and other methods to improve GM performance, which are discussed in this meeting report.

  17. Effects of laser acupoint irradiation on blood glucose and glycosylated hemoglobin in type 2 diabetes mellitus

    Science.gov (United States)

    Hui-Hui, Liu; Guo-Xin, Xiong; Li-Ping, Zhang

    2016-06-01

    To investigate the effects of semiconductor laser acupoint irradiation on blood glucose, glycosylated hemoglobin and physical fitness in type 2 diabetes mellitus, 44 cases of type 2 diabetic patients were randomly divided into a control group and a treatment group. All patients in both groups were given a drug treatment. The Hegu, Quchi and Zusanli acupoints of patients in the treatment group were then irradiated daily for 15 d with a 10 MW semiconductor laser. Before and after treatment, patients in both groups underwent a variety of tests and measurements: a two-hour postprandial blood glucose test; a glycosylated hemoglobin test and body mass index (BMI), waist-to-hip ratio (WHR) and body fat percentage (BFP) measurements. The data detected after treatment greatly decreased in the treatment group and was significantly different from that in the control group. It is shown that the acupoint irradiation with a semiconductor laser can improve two-hour postprandial blood glucose, glycosylated hemoglobin and some physical fitness measurements in type 2 diabetes mellitus patients.

  18. A Simple Laboratory Experiment to Determine the Kinetics of Mutarotation of D-Glucose Using a Blood Glucose Meter

    Science.gov (United States)

    Perles, Carlos E.; Volpe, Pedro L. O.

    2008-01-01

    A simple commercial blood glucose meter is used to follow the kinetics of mutarotation of D-glucose in aqueous solution. The results may be compared with those obtained using an automatic polarimeter, if this is available This experiment is proposed for use by students in a general chemistry, biology, organic chemistry, and physical chemistry…

  19. Blood glucose meter with biochemical analyzer blood glucose than on analysis%血糖仪与生化分析仪测定血糖的比对分析

    Institute of Scientific and Technical Information of China (English)

    秦亚军; 张保龙; 杨笑琼

    2013-01-01

      目的:探讨血糖仪与生化分析仪测定血糖的比对情况,为合理选择血糖检测方法提供参考。方法:选择2009年2月~2012年8月在我院门诊住院患者糖尿病人员共120例,上肢肘静脉和手指末端分别采血进行生化分析仪与血糖仪检测。结果:经过检测,生化分析仪检测的血糖值为(6.30±0.22)mmol/L,血糖仪检测的血糖值为(6.25±1.89)mmol/L,两种方法检测值对比无明显差异(P>0.05)。但是血糖仪检测的重复性不强,导致s值比较大。结论:血糖仪在糖尿病患者的血糖监测中有很大的局限性,在临床中要将血糖仪的监测和医院血糖检测结合使用,才能达到良好的血糖控制目的。%Objective:To investigate the blood glucose meter and biochemical analyzer than on blood sugar, and provide a reference for the reasonable choice of blood glucose testing method. Methods:From February 2009 to August 2012, a total of 120 cases of staff in our hospital hospitalized patients with diabetes, venous and finger blood samples were collected at the end of the upper limb elbow biochemical analyzer and blood glucose meter testing. Results:After testing, the the biochemical analyzer blood sugar value of (6.30± 0.22)mmol/L, blood glucose meter testing blood sugar value of (6.25±1.89)mmol/L, two methods for detecting the value of contrast was no significant difference(P>0.05). However, the reproducibility of the blood glucose meter detecting is not strong, resulting in the value of s is relatively large. Conclusion: The blood glucose meter glucose monitoring in diabetes has many limitations, combined To glucometer monitoring and hospital blood glucose testing in clinical use, in order to achieve good glycemic control purposes.

  20. Determination of Blood Glucose Concentration by Using Wavelet Transform and Neural Networks

    Directory of Open Access Journals (Sweden)

    Vajravelu Ashok

    2013-03-01

    Full Text Available Background: Early and non-invasive determination of blood glucose level is of great importance. We aimed to present a new technique to accurately infer the blood glucose concentration in peripheral blood flow using non-invasive optical monitoring system.Methods: The data for the research were obtained from 900 individuals. Of them, 750 people had diabetes mellitus (DM. The system was designed using a helium neon laser source of 632.8 nm wavelength with 5mW power, photo detectors and digital storage oscilloscope. The laser beam was directed through a single optical fiber to the index finger and the scattered beams were collected by the photo detectors placed circumferentially to the transmitting fiber. The received signals were filtered using band pass filter and finally sent to a digital storage oscilloscope. These signals were then decomposed into approximation and detail coefficients using modified Haar Wavelet Transform. Back propagation neural and radial basis functions were employed for the prediction of blood glucose concentration.Results: The data of 450 patients were randomly used for training, 225 for testing and the rest for validation. The data showed that outputs from radial basis function were nearer to the clinical value. Significant variations could be seen from signals obtained from patients with DM and those without DM.Conclusion: The proposed non-invasive optical glucose monitoring system is able to predict the glucose concentration by proving that there is a definite variation in hematological distribution between patients with DM and those without DM.

  1. Age-related memory impairments due to reduced blood glucose responses to epinephrine

    OpenAIRE

    Morris, Ken A.; Chang, Qing; Mohler, Eric G.; Gold, Paul E.

    2009-01-01

    Increases in blood glucose levels are an important component of the mechanisms by which epinephrine enhances memory formation. The present experiments addressed the hypothesis that a dysfunction in the blood glucose response to circulating epinephrine contributes to age-related memory impairments. Doses of epinephrine and glucagon that significantly increased blood glucose levels in young adult rats were far less effective at doing so in two-year-old rats. In young rats, epinephrine and gluco...

  2. Investigation of the Blood Glucose Lowering Potential of the Jamaican Momordica charantia (Cerasee) Fruit in Sprague-Dawley Rats.

    Science.gov (United States)

    Burnett, A; McKoy, M L; Singh, P

    2015-09-01

    The Momordica charantia (MC) fruit has been documented to possess antidiabetic properties. However, these studies were not without controversy surrounding the blood glucose-lowering ability and the mechanism of action in diabetes therapy. In an effort to evaluate such claims in the Jamaican MC species known as cerasee, aqueous extracts of the unripe fruit were studied in normal and diabetic rats. Normal male Sprague-Dawley rats were divided into groups (n = 6) orally administered distilled water, 10% dimethyl sulfoxide (DMSO) solution, the aqueous extract (400 mg/kg body weight) and glibenclamide (15 mg/kg body weight), respectively prior to assessment of fasting blood glucose (FBG) concentration. The oral glucose tolerance test (OGTT) was conducted in normoglycaemic rats orally administered distilled water, 10% DMSO solution, glibenclamide (15 mg/kg body weight) or aqueous extracts of the fruit (200 and 400 mg/kg body weight). Blood glucose concentration was also monitored in streptozotocin-induced diabetic rats administered the aqueous extract (250 mg/kg body weight) or water vehicle after an overnight fast. The aqueous extracts showed no hypoglycaemic or antidiabetic activity. However, the administration of the aqueous extracts (200 and 400 mg/kg body weight) resulted in significant improvement in glucose tolerance of glucose-primed normoglycaemic rats during the OGTT. These data suggest that the glucose-lowering mechanism of the Jamaican MC fruit species likely involves altered glucose absorption across the gastrointestinal tract. PMID:26624580

  3. Oral glucose tolerance test in unstimulated saliva of healthy individuals

    OpenAIRE

    Mohammad-Hossein Mirzaii-Dizgah; Iraj Mirzaii-Dizgah; Mohammad-Reza Mirzaii-Dizgah

    2016-01-01

    Objective: The aim of this study was to investigate oral glucose tolerance test (OGTT) in unstimulated whole saliva as a diagnostic specimen in clinical practice for detection of diabetes mellitus (DM). Materials and Methods: An interventional study was carried out in 30 apparently healthy individuals aged 24–59 years. Serum and saliva samples were obtained in fasting, 1 h and 2 h after glucose intake (75 g). Glucose concentration was determined by enzymatic colorimetric glucose oxidase-prost...

  4. A comprehensive compartmental model of blood glucose regulation for healthy and type 2 diabetic subjects

    DEFF Research Database (Denmark)

    Vahidi, O; Kwok, K E; Gopaluni, R B;

    2016-01-01

    We have expanded a former compartmental model of blood glucose regulation for healthy and type 2 diabetic subjects. The former model was a detailed physiological model which considered the interactions of three substances, glucose, insulin and glucagon on regulating the blood sugar. The main...... drawback of the former model was its restriction on the route of glucose entrance to the body which was limited to the intravenous glucose injection. To handle the oral glucose intake, we have added a model of glucose absorption in the gastrointestinal tract to the former model to address the resultant...... variations of blood glucose concentrations following an oral glucose intake. Another model representing the incretins production in the gastrointestinal tract along with their hormonal effects on boosting pancreatic insulin production is also added to the former model. We have used two sets of clinical data...

  5. An artificial pancreas provided a novel model of blood glucose level variability in beagles.

    Science.gov (United States)

    Munekage, Masaya; Yatabe, Tomoaki; Kitagawa, Hiroyuki; Takezaki, Yuka; Tamura, Takahiko; Namikawa, Tsutomu; Hanazaki, Kazuhiro

    2015-12-01

    Although the effects on prognosis of blood glucose level variability have gained increasing attention, it is unclear whether blood glucose level variability itself or the manifestation of pathological conditions that worsen prognosis. Then, previous reports have not been published on variability models of perioperative blood glucose levels. The aim of this study is to establish a novel variability model of blood glucose concentration using an artificial pancreas. We maintained six healthy, male beagles. After anesthesia induction, a 20-G venous catheter was inserted in the right femoral vein and an artificial pancreas (STG-22, Nikkiso Co. Ltd., Tokyo, Japan) was connected for continuous blood glucose monitoring and glucose management. After achieving muscle relaxation, total pancreatectomy was performed. After 1 h of stabilization, automatic blood glucose control was initiated using the artificial pancreas. Blood glucose level varied for 8 h, alternating between the target blood glucose values of 170 and 70 mg/dL. Eight hours later, the experiment was concluded. Total pancreatectomy was performed for 62 ± 13 min. Blood glucose swings were achieved 9.8 ± 2.3 times. The average blood glucose level was 128.1 ± 5.1 mg/dL with an SD of 44.6 ± 3.9 mg/dL. The potassium levels after stabilization and at the end of the experiment were 3.5 ± 0.3 and 3.1 ± 0.5 mmol/L, respectively. In conclusion, the results of the present study demonstrated that an artificial pancreas contributed to the establishment of a novel variability model of blood glucose levels in beagles.

  6. Prevalence of glucose-6-phosphate dehydrogenase deficiency and sickle cell trait among blood donors in Riyadh

    Directory of Open Access Journals (Sweden)

    Alabdulaali Mohammed

    2010-01-01

    Full Text Available Background and Aims: Blood donation from glucose-6-phosphate dehydrogenase (G6PD-deficient and sickle cell trait (SCT donors might alter the quality of the donated blood during processing, storage or in the recipient′s circulatory system. The aim of this study was to determine the prevalence of G6PD deficiency and SCT among blood donors coming to King Khalid University Hospital (KKUH in Riyadh. It was also reviewed the benefits and risks of transfusing blood from these blood donors. Materials and Methods: This cross-sectional study was conducted on 1150 blood samples obtained from blood donors that presented to KKUH blood bank during the period April 2006 to May 2006. All samples were tested for Hb-S by solubility test, alkaline gel electrophoresis; and for G6PD deficiency, by fluorescent spot test. Results: Out of the 1150 donors, 23 (2% were diagnosed for SCT, 9 (0.78% for G6PD deficiency and 4 (0.35% for both conditions. Our prevalence of SCT and G6PD deficiency is higher than that of the general population of Riyadh. Conclusion: We recommend to screen all units for G6PD deficiency and sickle cell trait and to defer donations from donors with either of these conditions, unless if needed for special blood group compatibility, platelet apheresis or if these are likely to affect the blood bank inventory. If such blood is to be used, special precautions need to be undertaken to avoid complications in high-risk recipients.

  7. Investigation the effect of Commiphora mukul on blood glucose and Serum lipid profile in diabetic rats

    Directory of Open Access Journals (Sweden)

    leila Shirazi

    2015-01-01

    Full Text Available Background & aim: The decrease of serum glucose level and lipids in diabetic patients is clinically significant. The purpose of this study was to determine the effect of Commiphora mukul extract on blood sugar and lipid profile in diabetic rats. Methods: In the present experimental study, thirty-two male Wistar rats were randomly divided into four groups: control, control treated with the extract, diabetic and diabetic treated with the extract. Diabetes was induced by intraperitoneal injection of Streptozotocin. In an eight week period, the control group of normal saline and the control group and diabetic recipient extract of CM oleo gum blue resin was given by gavage. Treatment resumed eight weeks with onset of hyperglycemia. The control and diabetic control groups received normal saline orally. Extract treated control and extract treated diabetic groups received extract of Commiphora mukul gum (300 mg/kg P.O. daily by gavage. At the end of this period, blood samples were collected from each rat and biochemical tests for investigation of glucose level and lipid profile was performed. One- way analysis of variance (ANOVA statistical test and Post-hoc test Tukey’s were used for data analysis Results: The study indicated that diabetes increases the serum levels of glucose, cholesterol, triglycerides, LDL and HDL. Administration of Commiphora mukul gum extract in diabetic groups significantly decreased the serum level of glucose, cholesterol(p<0.01 and triglyceride and LDL(p<0.001 and increased HDL(p<0.01. Conclusion: Commiphora mukul gum extract may well improve undesirable effects of diabetes on serum level of glucose, cholesterol, triglyceride, LDL and HDL.

  8. ASVCP guidelines: quality assurance for portable blood glucose meter (glucometer) use in veterinary medicine.

    Science.gov (United States)

    Gerber, Karen L; Freeman, Kathleen P

    2016-03-01

    Portable blood glucose meters (PBGM, glucometers) are a convenient, cost effective, and quick means to assess patient blood glucose concentration. The number of commercially available PBGM is constantly increasing, making it challenging to determine whether certain glucometers may have benefits over others for veterinary testing. The challenge in selection of an appropriate glucometer from a quality perspective is compounded by the variety of analytic methods used to quantify glucose concentrations and disparate statistical analysis in many published studies. These guidelines were developed as part of the ASVCP QALS committee response to establish recommendations to improve the quality of testing using point-of-care testing (POCT) handheld and benchtop devices in veterinary medicine. They are intended for clinical pathologists and laboratory professionals to provide them with background knowledge and specific recommendations for quality assurance (QA) and quality control (QC), and to serve as a resource to assist the provision of advice to veterinarians and technicians to improve the quality of results obtained when using PBGM. These guidelines are not intended to be all-inclusive; rather they provide a minimum standard for management of PBGM in the veterinary setting.

  9. Analysis of results of oral glucose tolerance test (OGTT) and insulin releasing test in hepatogenic diabetics

    International Nuclear Information System (INIS)

    Objective: To explore the clinical values of OGTT and insulin releasing test in hepatogenic diabetics. Method: OGTT was performed by enzymes method and insulin releasing test by RIA in 30 patients with hepatogenic diabetes, 31 cases with II diabetes and 35 controls. Results: During OGTT, blood glucose levels at various time were about the same in hepatogenic diabetics and II diabetics (P < 0.05), except at 180 min (P < 0.01). Basal hyperinsulinemia was present is hepatogenic diabetics. Conclusion: OGTT and insulin releasing test had a definite clinical value in the differential diagnosis of hepatogenic diabetics

  10. 75 FR 2549 - Clinical Accuracy Requirements for Point of Care Blood Glucose Meters; Public Meeting; Request...

    Science.gov (United States)

    2010-01-15

    ...) Clinical accuracy for blood glucose meters, (2) tight glycemic control in clinical settings, and (3... allow for better glycemic control by diabetics than in the past. Glucose meters are not only used by... evaluated by FDA. For example, glucose meters are increasingly being used to achieve tight glycemic...

  11. Elective Percutaneous Coronary Intervention: The Relationship between Preprocedural Blood Glucose Levels and Periprocedural Myocardial Injury

    OpenAIRE

    Madani, Mohsen; Alizadeh, Keivan; Ghazaee, Sepideh Parchami; Zavarehee, Abbas; Abdi, Seifollah; Shakerian, Farshad; salehi, Negar; Firouzi, Ata

    2013-01-01

    Regardless of the diabetic status of patients with coronary artery disease, hyperglycemia and hypoglycemia are adversely associated with cardiovascular events. The relationship between glucose levels and increased mortality risk in acute myocardial infarction has been shown through various glucose metrics; however, there is a dearth of multivariate analysis of the relationship between elective coronary angioplasty and preprocedural blood glucose levels.

  12. Comparison of blood glucose concentrations after administration of a glucose solution via the jugular vein and portal vein in cows.

    Science.gov (United States)

    Braun, U; Heusmann, B; Camenzind, D; Haessig, M

    2007-10-01

    The goals of the present study were to determine whether the infusion of a glucose solution into the portal vein is tolerated in cows and whether the glucose concentration differs after administration of glucose into the jugular vein and portal vein. Fifteen healthy Swiss Braunvieh cows were used. An indwelling catheter was placed in both jugular veins and a balloon-tipped indwelling catheter with a diameter of 2 mm was placed in the portal vein under the guidance of ultrasonography. Three cows received 500 ml of 20% glucose solution over 60 min via the left jugular vein. Three other cows received the same solution over 60 min via the portal vein. Blood samples were collected from the right jugular vein before and for 24 h after the infusion of glucose for the determination of the concentrations of glucose and bilirubin and the activities of glutamate dehydrogenase, sorbitol dehydrogenase and gamma-glutamyl transferase. Infusion via the portal vein did not result in abnormalities in the general condition of the cows or increases in the concentration of bilirubin or the activities of liver enzymes. The blood glucose concentration increased to the same extent after both intraportal and intrajugular infusion. Over a 12-h period, three cows received 10 l of 20% glucose solution via the left jugular vein and three others received the same solution over a 12-h period via the portal vein. Blood samples were collected from the right jugular vein before and for 30 h after the start of infusion. Infusion via the portal vein did not affect the general condition of the cows or the activities of the liver enzymes. There was no significant difference in the blood glucose concentration between the two groups throughout the study.

  13. Frequency and motives of blood glucose self-monitoring in type 1 diabetes

    DEFF Research Database (Denmark)

    Hansen, M.V.; Pedersen-Bjergaard, U.; Heller, S.R.;

    2009-01-01

    AIMS: Recommendations for self-monitoring of blood glucose (SMBG) from the DCCT have not been implemented with the same rigour as recommendations for intensifying insulin therapy. We assessed the frequency of and motives for SMBG and compared SMBG behaviour with clinical, behavioural and...... hypoglycaemia and awareness of hypoglycaemia were independently associated with testing behaviour, whereas the presence of late diabetic complications was not. Lower HbA1c was associated with more frequent testing. CONCLUSION: Patient compliance regarding SMBG is limited. Thus, almost two thirds of the patients...

  14. Carbon dot based non enzymatic approach for the detection and estimation of glucose in blood serum

    Science.gov (United States)

    Shanti Krishna, A.; Nair, Priya A.; Radhakumary, C.; Sreenivasan, K.

    2016-05-01

    In this study we generated a simple, reliable and selective approach based on carbon dots (CDs) and 4-cyanophenylboronic acid (CPBA) for blood glucose sensing. The methodology relies on the quenching of the emission of CDs by CPBA followed by its recovery by glucose. The system consisting of CDs and CPBA was characterised by Fourier transform infra red spectrum, transmissions electron microscopic, dynamic light scattering instrument, UV–visible and fluorescence techniques. The response of the probe, CD-BA in presence of different concentrations of glucose was assessed. Linear range was obtained for glucose concentrations ranging from 1 to 30 mM. Interferences by other saccharides and various biomolecules coexisting in blood serum were negligible. The chemo sensor thus developed has been successfully used for the estimation of glucose in human blood serum. The system being sensitive, efficient and easy to perform is a promising platform for blood glucose sensing.

  15. Evaluation of two methods of rapid blood-glucose monitoring by unskilled personnel during surgery

    DEFF Research Database (Denmark)

    Madsbad, S; Adelhøj, B; Bigler, Dennis Richard;

    1984-01-01

    The accuracy of two rapid methods of blood-glucose monitoring without (Haemo-glucotest 1-44) and with a reflectance meter (Hypocount B) was compared using a laboratory method. The assessment was carried out by personnel with no previous experience in measuring blood glucose. Eighty-five percent o...

  16. Effect of Cnidoscolus aconitifolius leaf extract on the blood glucose and insulin levels of inbred type 2 diabetic mice.

    Science.gov (United States)

    Oladeinde, F O; Kinyua, A M; Laditan, A A; Michelin, R; Bryant, J L; Denaro, F; Makinde, J M; Williams, A L; Kennedy, A P; Bronner, Y

    2007-01-01

    The effects of Cnidoscolus aconitifolius (CA) leaf extract and chlorpropamide on blood glucose and insulin levels in the inbred type 2 diabetic mice are reported. After treatment with CA, the glucose levels were measured at 0 and 2-hour intervals in experimental groups and controls. Group I received no treatment and served as control; Group II was the reference and it received chlorpropamide; Groups I-III were moderately diabetic, 100-300 mg/dL blood glucose levels while Group IV were severely diabetic (> 300 mg/dL). Groups III and IV received CA and served as test groups. There was no significant difference between the blood glucose levels at 0 and 2 hours for the control group, (P>0.23) but there were statistically significant differences for Group II (P<0.0002); Group III (P<0.002) and Group IV (P<0.0001). For moderately diabetic mice, CA and chlorpropamide decreased the glucose levels by 25.6% and 16.3% respectively while for the severely diabetic mice CA decreased the blood glucose by 43.7%. It is proposed that CA has an insulinogenic property that possibly stimulated dormant beta-cells to secrete insulin. The histopathology of several organs in the treated animals was found to differ from the expected. The islets of Langerhans for example were found to be preserved in the time frame examined. Also the liver and kidney were found to display milder pathology in the treated groups. PMID:17531147

  17. A switching control strategy for the attenuation of blood glucose disturbances

    OpenAIRE

    Markakis, Mihalis G.; Mitsis, Georgios D.; Papavassilopoulos, George P.; Ioannou, Petros A.; Marmarelis, Vasilis Z.

    2011-01-01

    In this computational study we consider a generalized minimal model structure for the intravenously infused insulin–blood glucose dynamics, which can represent a wide variety of diabetic patients, and augment this model structure with a glucose rate disturbance signal that captures the aggregate effects of various internal and external factors on blood glucose. Then we develop a model-based, switching controller, which attempts to balance between optimal performance, reduced computational com...

  18. A Meta-Analysis of Blood Glucose Effects on Human Decision Making

    DEFF Research Database (Denmark)

    Orquin, Jacob Lund; Kurzban, Robert

    2016-01-01

    The academic and public interest in blood glucose and its relationship to decision making has been increasing over the last decade. To investigate and evaluate competing theories about this relationship, we conducted a psychometric meta-analysis on the effect of blood glucose on decision making. We...... identified 42 studies relating to 4 dimensions of decision making: willingness to pay, willingness to work, time discounting, and decision style. We did not find a uniform influence of blood glucose on decision making. Instead, we found that low levels of blood glucose increase the willingness to pay...... and willingness to work when a situation is food related, but decrease willingness to pay and work in all other situations. Low levels of blood glucose increase the future discount rate for food; that is, decision makers become more impatient, and to a lesser extent increase the future discount rate for money...

  19. The value of episodic, intensive blood glucose monitoring in non-insulin treated persons with type 2 diabetes: Design of the Structured Testing Program (STeP Study, a cluster-randomised, clinical trial [NCT00674986

    Directory of Open Access Journals (Sweden)

    Jelsovsky Zhihong

    2010-05-01

    Full Text Available Abstract Background The value and utility of self-monitoring of blood glucose (SMBG in non-insulin treated T2DM has yet to be clearly determined. Findings from studies in this population have been inconsistent, due mainly to design differences and limitations, including the prescribed frequency and timing of SMBG, role of the patient and physician in responding to SMBG results, inclusion criteria that may contribute to untoward floor effects, subject compliance, and cross-arm contamination. We have designed an SMBG intervention study that attempts to address these issues. Methods/design The Structured Testing Program (STeP study is a 12-month, cluster-randomised, multi-centre clinical trial to evaluate whether poorly controlled (HbA1c ≥ 7.5%, non-insulin treated T2DM patients will benefit from a comprehensive, integrated physician/patient intervention using structured SMBG in US primary care practices. Thirty-four practices will be recruited and randomly assigned to an active control group (ACG that receives enhanced usual care or to an enhanced usual care group plus structured SMBG (STG. A total of 504 patients will be enrolled; eligible patients at each site will be randomly selected using a defined protocol. Anticipated attrition of 20% will yield a sample size of at least 204 per arm, which will provide a 90% power to detect a difference of at least 0.5% in change from baseline in HbA1c values, assuming a common standard deviation of 1.5%. Differences in timing and degree of treatment intensification, cost effectiveness, and changes in patient self-management behaviours, mood, and quality of life (QOL over time will also be assessed. Analysis of change in HbA1c and other dependent variables over time will be performed using both intent-to-treat and per protocol analyses. Trial results will be available in 2010. Discussion The intervention and trial design builds upon previous research by emphasizing appropriate and collaborative use of

  20. Blood Glucose Control Using a Novel Continuous Blood Glucose Monitor and Repetitive Intravenous Insulin Boluses: Exploiting Natural Insulin Pulsatility as a Principle for a Future Artificial Pancreas

    Directory of Open Access Journals (Sweden)

    Nils K. Skjaervold

    2013-01-01

    Full Text Available The aim of this study was to construct a glucose regulatory algorithm by employing the natural pulsatile pattern of insulin secretion and the oscillatory pattern of resting blood glucose levels and further to regulate the blood glucose level in diabetic pigs by this method. We developed a control algorithm based on repetitive intravenous bolus injections of insulin and combined this with an intravascular blood glucose monitor. Four anesthetized pigs were used in the study. The animals developed a mildly diabetic state from streptozotocin pretreatment. They were steadily brought within the blood glucose target range of 4.5–6.0 mmol/L in 21 to 121 min and kept within that range for 128 to 238 min (hypoglycemic values varied from 2.9 to 51.1 min. The study confirmed our hypotheses regarding the feasibility of this new principle for blood glucose control, and the algorithm was constantly improved during the study to produce the best results in the last animals. The main obstacles were the drift of the IvS-1 sensor and problems with the calibration procedure, which calls for an improvement in the sensor stability before this method can be applied fully in new studies in animals and humans.

  1. Evaluation of OneTouch Verio(®), a new blood glucose self-monitoring system for patients with diabetes

    DEFF Research Database (Denmark)

    Littmann, Karin; Petersen, Eva; Pussinen, Christel;

    2013-01-01

    Introduction. Self-monitoring of blood glucose (SMBG) is important in diabetes management. Reliable and user-friendly instruments are essential. OneTouch Verio(®) is a new blood glucose concentration-measuring system designed to be used by patients with diabetes and healthcare professionals. The ...... between strip lots. Conclusion. The OneTouch Verio(®) displayed sufficient analytical quality and satisfactory user-friendliness. It is suitable for point-of-care testing of blood glucose concentration when handled by patients and healthcare professionals.......Introduction. Self-monitoring of blood glucose (SMBG) is important in diabetes management. Reliable and user-friendly instruments are essential. OneTouch Verio(®) is a new blood glucose concentration-measuring system designed to be used by patients with diabetes and healthcare professionals....... The objective of the present study was to evaluate the analytical performance of the OneTouch Verio(®). Method. The OneTouch Verio(®) was evaluated by the Scandinavian evaluation of laboratory equipment for primary healthcare (SKUP) according to a protocol based on ISO 15197 and the American Diabetes...

  2. Evaluation of OneTouch Verio, a new blood glucose self-monitoring system for patients with diabetes

    DEFF Research Database (Denmark)

    Littman, Karin; Petersen, Eva R.B.; Pussinen, Christel;

    2013-01-01

    Introduction. Self-monitoring of blood glucose (SMBG) is important in diabetes management. Reliable and user-friendly instruments are essential. OneTouch Verio® is a new blood glucose concentration-measuring system designed to be used by patients with diabetes and healthcare professionals. The ob....... Conclusion. The OneTouch Verio® displayed sufficient analytical quality and satisfactory user-friendliness. It is suitable for point-of-care testing of blood glucose concentration when handled by patients and healthcare professionals.......Introduction. Self-monitoring of blood glucose (SMBG) is important in diabetes management. Reliable and user-friendly instruments are essential. OneTouch Verio® is a new blood glucose concentration-measuring system designed to be used by patients with diabetes and healthcare professionals....... The objective of the present study was to evaluate the analytical performance of the OneTouch Verio®. Method. The OneTouch Verio® was evaluated by the Scandinavian evaluation of laboratory equipment for primary healthcare (SKUP) according to a protocol based on ISO 15197 and the American Diabetes Association...

  3. An enzymatic glucose/O2 biofuel cell operating in human blood.

    Science.gov (United States)

    Cadet, Marine; Gounel, Sébastien; Stines-Chaumeil, Claire; Brilland, Xavier; Rouhana, Jad; Louerat, Frédéric; Mano, Nicolas

    2016-09-15

    Enzymatic biofuel cells (BFCs) may power implanted medical devices and will rely on the use of glucose and O2 available in human bodily fluids. Other than well-established experiments in aqueous buffer, little work has been performed in whole human blood because it contains numerous inhibiting molecules. Here, we tested our BFCs in 30 anonymized, random and disease-free whole human blood samples. We show that by designing our anodic and cathodic bioelectrocatalysts with osmium based redox polymers and home-made enzymes we could reach a high selectivity and biofunctionnality. After optimization, BFCs generate power densities directly proportional to the glycaemia of human blood and reached a maximum power density of 129µWcm(-2) at 0.38V vs. Ag/AgCl at 8.22mM glucose. This is to our knowledge the highest power density attained so far in human blood and open the way for the powering of integrated medical feedback loops. PMID:27107143

  4. The use of Fourier-transform infrared spectroscopy for the quantitative determination of glucose concentration in whole blood.

    Science.gov (United States)

    Shen, Y C; Davies, A G; Linfleld, E H; Elsey, T S; Taday, P F; Arnone, D D

    2003-07-01

    Fourier-transform infrared transmission spectroscopy has been used for the determination of glucose concentration in whole blood samples from 28 patients. A 4-vector partial least-squares calibration model, using the spectral range 950-1200 cm(-1), yielded a standard-error-of-prediction of 0.59 mM for an independent test set. For blood samples from a single patient, we found that the glucose concentration was proportional to the difference between the values of the second derivative spectrum at 1082 cm(-1) and 1093 cm(-1). This indicates that spectroscopy at these two specific wavenumbers alone could be used to determine the glucose concentration in blood plasma samples from a single patient, with a prediction error of 0.95 mM. PMID:12884933

  5. Intraoperative blood glucose levels in neurosurgical patients : an evaluation of two fluid regimens.

    Directory of Open Access Journals (Sweden)

    Swamy M

    2001-10-01

    Full Text Available Based on the evidence that hyperglycaemia aggravates ischaemic cerebral injury, it has been suggested that blood glucose levels be kept within 200 mg/dL during intracranial neurosurgery. Hypoglycaemia, however, can be a serious problem if glucose-containing solutions are avoided during the first four hours, as suggested in some studies. In order to explore the possibility of administering glucose in moderation so that the blood glucose levels are within acceptable limits, but at the same time the risk of hyoglycaemia is eliminated, we compared two intraoperative fluid regimens. Of the 52 neurosurgical patients studied, 32 patients received alternately 500 ml of 5% dextrose in normal saline and Ringer′s lactate (DNS/RL Group and 18 patients received alternately 500 ml of Ringer′s lactate and normal saline (RL/NS Group. Blood glucose concentrations were determined at the end of each unit of fluid, until the patient received 4 units of fluid. In the DNS/RL group, blood glucose values peaked with the administration of each unit of DNS and tended to return towards the baseline with the subsequent RL, but remained higher than the previous control value. In the RL/NS group, there was a progressive increase in blood glucose values throughout the study period, but the increase was not statistically significant. The blood glucose levels were significantly different between the two groups after each unit of fluid except at the end of the fourth unit. Two patients in the RL/NS group had hypoglycaemia. In conclusion, the DNS/RL regimen maintains blood glucose levels within acceptable limits while avoiding the risk of hyperglycaemia. Withholding glucose completely, lowers blood glucose levels, but carries a risk of hypoglycaemia in some patients.

  6. Simultaneous measurement of blood flow and glucose metabolism by autoradiographic techniques

    International Nuclear Information System (INIS)

    A double tracer autoradiographic technique using 131I-iodo-antipyrine and 14C-deoxyglucose is presented for the simultaneous measurement of blood flow and cerebral glucose utilization in the same animal. 131I is a gamma emitting isotope with a half life of 8.06 days and can be detected with adequate resolution on standard autoradiographic films. Autoradiograms are made before and after decay of 131I; the time interval between the 2 exposures and the concentration of the 2 tracers is adjusted to avoid significant cross-contamination. In this way, 2 film exposures are obtained which can be processed quantitatively like single tracer autoradiograms. The validity of the method for the investigation of local coupling of flow and metabolism was tested under various physiological and pathophysiological conditions. Coupling was tight in barbiturate-anesthetized healthy animals, but not under halothane anesthesia where uncoupling occurred in various subcortical structures. Focal seizures induced by topical application of penicillin on the cortical surface led to a coupled increase of metabolism and flow in thalamic relay nuclei but not at the site of penicillin administration where increased glucose utilization was not accompanied by similar increase in blood flow. Both coupled and uncoupled increases in local glucose utilization were observed in spreading depression and in circumscribed areas of experimental brain tumors. The results obtained demonstrate that double tracer autoradiography allows allows the very precise local assessment of cerebral blood flow and glucose utilization, and, therefore, is particularly suited to the study of regional coupling processes under various experimental conditions

  7. Your Glucose Meter

    Science.gov (United States)

    ... by Audience For Women Women's Health Topics Your Glucose Meter Share Tweet Linkedin Pin it More sharing ... Español Basic Facts 7 Tips for Testing Your Blood Sugar and Caring for Your Meter Glucose meters test ...

  8. Evaluation of the Capillary Blood Glucose Self-monitoring Program

    Directory of Open Access Journals (Sweden)

    Mariana Cristina Augusto

    2014-10-01

    Full Text Available OBJECTIVE: to evaluate the structure, process and results of the Capillary Blood Glucose Self-monitoring Program in a Brazilian city.METHOD: epidemiological, cross-sectional study. The methodological framework of Donabedian was used to construct indicators of structure, process and outcome. A random sample (n = 288 of users enrolled and 96 health professionals who worked in the program was studied. Two questionnaires were used that were constructed for this study, one for professionals and one for users, both containing data for the evaluation of structure, process and outcome. Anthropometric measures and laboratory results were collected by consulting the patients' health records. The analysis involved descriptive statistics.RESULTS: most of the professionals were not qualified to work in the program and were not knowledgeable about the set of criteria for patient registration. None of the patients received complete and correct orientations about the program and the percentage with skills to perform conducts autonomously was 10%. As regards the result indicators, 86.4% of the patients and 81.3% of the professionals evaluated the program positively.CONCLUSION: the evaluation indicators designed revealed that one of the main objectives of the program, self-care skills, has not been achieved.

  9. [Comparative analysis of dependence of saliva sorbitol and fructosamine levels on blood glucose level in patients with diabetes].

    Science.gov (United States)

    Morenkova, S A

    2004-01-01

    The possibility of determination of sorbitol and fructosamine in saliva has been studied in healthy volunteers and patients with diabetes. The dependence of these metabolites levels in saliva on blood glucose level was demonstrated. It is concluded that saliva sorbitol and fructosamine levels measurements may be used as diagnostic tests in diabetes and serve as indicators of efficacy of therapy in diabetes. PMID:15707277

  10. Pulsed photoacoustic techniques and glucose determination in human blood and tissue

    OpenAIRE

    Zhao, Z.

    2002-01-01

    Abstract Determination of blood glucose level is a frequently occurring procedure in diabetes care. As the most common method involves collecting blood drops for chemical analysis, it is invasive and liable to afflict a degree of pain and cause a skin injury. To eliminate these disadvantages, this thesis focuses on pulsed photoacoustic techniques, which have potential ability in non-invasive blood glucose measurement. The fundamental theory of photoacoustics in liquid and soft tissue ...

  11. Compensatory Beliefs about Glucose Testing are Associated with Low Adherence to Treatment and Poor Metabolic Control in Adolescents with Type 1 Diabetes

    Science.gov (United States)

    Rabiau, Marjorie A.; Knauper, Barbel; Nguyen, Thien-Kim; Sufrategui, Maria; Polychronakos, Constantin

    2009-01-01

    The goal of this research was to investigate whether compensatory beliefs (CBs) regarding glucose testing predict blood glucose levels and adherence to treatment in adolescents with type 1 diabetes. CBs are convictions that the negative effects of one behavior (e.g. not testing one's glucose level) can be compensated for by engaging in another…

  12. Clinical Testing of Blood Glucose Meter Rapid Clinical Significance and Ap-plication of Conventional Biochemical Analyzer%刍议临床血糖检验中快速血糖仪与常规生化仪应用的临床意义

    Institute of Scientific and Technical Information of China (English)

    王金英

    2015-01-01

    目的:研究快速血糖仪以及常规生化仪应用于临床血糖检验工作中发挥的效果。方法选择2013年5月-2014年5月该院68例患者,按每组34例分别设置对照组和观察组,对照组选择常规生化仪开展血糖检验工作,观察组通过快速血糖仪对患者血糖进行临床检验,比较两组检验结果。结果对照组患者最终测出的血糖值为(7.73±3.26)mmol/L;观察组患者最终的血糖检验值为(7.26±3.13)mmol/L,两组患者的检测结果差异无统计学意义(P>0.05)。结论针对患者的临床血糖检验工作,采用快速血糖仪以及常规生化仪所检出的结果不存在显著区别,应用效果不存在明显差异,但是快速血糖仪在检验操作上更为快捷和方便,应用优势较突出。%Objective To study the fast blood glucose meter and biochemical analyzer used in clinical routine blood test work, play effect. Methods From May 2013 to May 2014 in our hospital 68 patients, 34 cases in each group were set ac-cording to the control group and observation group and control group selection routine blood chemistry analyzer to carry out inspection work, study group patients by rapid blood glucose meter clinical blood test, the test results were compared. Re-sults The final group of patients measured blood glucose value (7.73 ± 3.26) mmol / L; Observation group were eventually glucose test is ( 7.26±3.13)mmol/ L, the test results of the two groups were not significantly different, not statistically sig-nificance (P>0.05). Conclusion For patients with clinical blood test work, using rapid blood glucose meter and convention-al biochemical analyzer results are detected significant differences do not exist, there is no significant difference in the ef-fect of the application, but a more rapid glucose meter quick and easy on the test operation, the application more prominent advantages.

  13. Effect and potential mechanism of action of sea cucumber saponins on postprandial blood glucose in mice.

    Science.gov (United States)

    Fu, Xueyuan; Wen, Min; Han, Xiuqing; Yanagita, Teruyoshi; Xue, Yong; Wang, Jingfeng; Xue, Changhu; Wang, Yuming

    2016-06-01

    Postprandial blood glucose control is the major goal in the treatment of diabetes. Here, we investigated the effect of sea cucumber saponins (SCSs) on postprandial blood glucose levels. SCS inhibited yeast as well as rat intestinal α-glucosidase activity in a dose-dependent manner and showed better inhibition of yeast α-glucosidases compared to the positive control. Further studies were performed using ICR mice treated with SCS and starch or SCS alone by oral gavage. Unexpectedly, SCS increased postprandial blood glucose levels a short time (1 h) after oral gavage. The serum corticosterone (CORT) level showed a consistent correlation with glucose levels. In vitro experiments confirmed that SCS treatment increased the secretion of CORT in the Y1 adrenal cell line. Overall, these studies demonstrated that SCS gavage could inhibit α-glucosidase activity but cannot attenuate postprandial blood glucose level within short time periods. The underlying mechanisms are probably related to increased serum CORT levels. PMID:26932154

  14. Training to estimate blood glucose and to form associations with initial hunger

    Directory of Open Access Journals (Sweden)

    Bianchi Riccardo

    2006-12-01

    Full Text Available Abstract Background The will to eat is a decision associated with conditioned responses and with unconditioned body sensations that reflect changes in metabolic biomarkers. Here, we investigate whether this decision can be delayed until blood glucose is allowed to fall to low levels, when presumably feeding behavior is mostly unconditioned. Following such an eating pattern might avoid some of the metabolic risk factors that are associated with high glycemia. Results In this 7-week study, patients were trained to estimate their blood glucose at meal times by associating feelings of hunger with glycemic levels determined by standard blood glucose monitors and to eat only when glycemia was Conclusion Subjects could be trained to accurately estimate their blood glucose and to recognize their sensations of initial hunger at low glucose concentrations. These results suggest that it is possible to make a behavioral distinction between unconditioned and conditioned hunger, and to achieve a cognitive will to eat by training.

  15. Control of Blood Glucose for People with Type 1 Diabetes: an in Vivo Study

    DEFF Research Database (Denmark)

    Boiroux, Dimitri; Schmidt, Signe; Duun-Henriksen, Anne Katrine;

    2012-01-01

    variations of patient's physiology and lack of accuracy of glucose sensors. In this paper we design and discuss an algorithm for overnight closed-loop control of blood glucose in people with type 1 diabetes. The algorithm is based on Model Predictive Control (MPC). We use an oset-free autoregressive model......Since continuous glucose monitoring (CGM) technology and insulin pumps have improved recent years, a strong interest in a closed-loop articial pancreas for people with type 1 diabetes has arisen. Presently, a fully automated controller of blood glucose must face many challenges, such as daily...

  16. The Food and Drug Administration Is Now Preparing to Establish Tighter Performance Requirements for Blood Glucose Monitors

    OpenAIRE

    Klonoff, David C.

    2010-01-01

    On March 16 and 17, 2010, the Food and Drug Administration (FDA) presented a public meeting about blood glucose monitoring at the Gaithersberg Hilton Hotel. The meeting was intended to present expert opinions and solicit input from the public about whether to develop new regulatory policies for blood glucose monitors. The meeting was divided into three sections: (1) Clinical Accuracy Requirements for Blood Glucose Monitors, (2) Interferences and Limitations of Blood Glucose Monitors, and (3) ...

  17. High activity enables life on a high-sugar diet: blood glucose regulation in nectar-feeding bats

    OpenAIRE

    Kelm, Detlev H.; Simon, Ralph; Kuhlow, Doreen; Voigt, Christian C.; Ristow, Michael

    2011-01-01

    High blood glucose levels caused by excessive sugar consumption are detrimental to mammalian health and life expectancy. Despite consuming vast quantities of sugar-rich floral nectar, nectar-feeding bats are long-lived, provoking the question of how they regulate blood glucose. We investigated blood glucose levels in nectar-feeding bats (Glossophaga soricina) in experiments in which we varied the amount of dietary sugar or flight time. Blood glucose levels increased with the quantity of gluco...

  18. A paper disk equipped with graphene/polyaniline/Au nanoparticles/glucose oxidase biocomposite modified screen-printed electrode: toward whole blood glucose determination.

    Science.gov (United States)

    Kong, Fen-Ying; Gu, Sai-Xi; Li, Wei-Wei; Chen, Ting-Ting; Xu, Qin; Wang, Wei

    2014-06-15

    In this work, a convenient, fast, low cost, small sample volume and in situ detection of glucose in human whole blood has been developed by using a disposable screen-printed carbon electrode (SPCE) coupled with a paper disk. To perform the assay, the SPCE was modified with graphene/polyaniline/Au nanoparticles/glucose oxidase (Gr/PANI/AuNPs/GOD) biocomposite and then covered by a paper disk impregnated with the sample. After introducing PBS on the paper disk, the electrochemical measurement was carried out. The assay was based on measuring the current decrease of flavin adenine dinucleotide (FAD) in GOD provoked by the enzyme-substrate reaction using differential pulse voltammetry (DPV). The analytical performance was comparable to conventional methods, and covered the full range of clinically relevant concentrations of glucose in whole blood. This new paper-based electrochemical glucose sensor shows promise in applying point-of-care (POC) device in whole blood tests, and particularly being appropriate for use in the developing world and in resource-limited settings. PMID:24469540

  19. Oral glucose tolerance test in unstimulated saliva of healthy individuals

    Directory of Open Access Journals (Sweden)

    Mohammad-Hossein Mirzaii-Dizgah

    2016-01-01

    Full Text Available Objective: The aim of this study was to investigate oral glucose tolerance test (OGTT in unstimulated whole saliva as a diagnostic specimen in clinical practice for detection of diabetes mellitus (DM. Materials and Methods: An interventional study was carried out in 30 apparently healthy individuals aged 24–59 years. Serum and saliva samples were obtained in fasting, 1 h and 2 h after glucose intake (75 g. Glucose concentration was determined by enzymatic colorimetric glucose oxidase-prostatic acid phosphatase assay. Statistical analysis of the repeated ANOVA (followed Bonferroni post-hoc test and Pearson correlation coefficient were used. Results: The mean serum glucose concentration was significantly higher 1 h after glucose intake (152.32 ± 31.06 than both fasting state (106.38 ± 41.08; P < 0.001 and 2 h after glucose intake (125.21 ± 51.71; P < 0.001. Saliva glucose was also significantly higher 1 h after glucose intake (5.46 ± 2.41 than both fasting state (2.84 ± 1.46; P < 0.001 and 2 h after glucose intake (4.01 ± 1.91; P < 0.001. There were significant positive correlation between saliva and serum glucose concentration in fasting state (r = 0.502; P = 0.044, 1 h (r = 0.756; P = 0.0001, and 2 h (r = 0.543; P = 0.023 after oral glucose intake. Conclusion: It seems that unstimulated saliva can be used as an alternative to serum for diagnosis of DM in OGTT.

  20. Home Use Tests: Fecal Occult Blood

    Science.gov (United States)

    ... Procedures In Vitro Diagnostics Home Use Tests Fecal Occult Blood Share Tweet Linkedin Pin it More sharing ... test kit to measure the presence of hidden (occult) blood in your stool (feces). What is fecal ...

  1. Effect of sucrose-containing snacks on blood glucose control.

    Science.gov (United States)

    Wise, J E; Keim, K S; Huisinga, J L; Willmann, P A

    1989-06-01

    To determine whether ingestion of sucrose-containing snacks would affect blood glucose (BG) control, 16 subjects with insulin-dependent diabetes mellitus participated in a 5-day double-blind study at a diabetes camp. Eight subjects in the sucrose group ate sucrose-sweetened snacks twice a day, and 8 subjects in the control group ingested snacks that were sweetened with aspartame. The percentage of total daily calories derived from added sucrose was 7% for the sucrose group and 1% for the control group. Metabolic control was assessed by daily capillary BG measurements obtained before meals and the bedtime snack and by determination of serum fructosamine (F) concentrations on arrival at camp (day 0) and after 5 days on the study protocol (day 5). No significant difference was seen between the groups on day 0 (sucrose group [mean +/- SD]: BG 9.9 +/- 3.6 mM, F 3.54 +/- 0.38 mM; control group: BG 9.1 +/- 2.8 mM, F 3.74 +/- 0.71 mM) or day 5 (sucrose group: BG 8.8 +/- 2.6 mM, F 2.94 +/- 0.32 mM; control group: BG 7.4 +/- 2.8 mM, F 2.92 +/- 0.59 mM). We conclude that ingestion of sucrose, added to snacks in an amount up to 7% of total energy intake, does not adversely affect short-term BG control. PMID:2659302

  2. Application of optical lens of a CD writer for detecting the blood glucose semi-invasively

    Science.gov (United States)

    Meshram, N. D.; Dahikar, P. B.

    2014-10-01

    Recent technological advancements in the photonics industry have led to a resurgence of interest in optical glucose sensing and to realistic progress toward the development of an optical glucose sensor. Such a sensor has the potential to significantly improve the quality of life for the estimated 16 million diabetics in this country by making routine glucose measurements more convenient. Currently over 100 small companies and universities are working to develop noninvasive or minimally invasive glucose sensing technologies, and optical methods play a large role in these efforts. It has become overwhelmingly clear that frequent monitoring and tight control of blood sugar levels are requisite for effective management of Diabetes mellitus and reduction of the complications associated with this disease. The pain and trouble associated with current "finger-stick" methods for blood glucose monitoring result in decreased patient compliance and a failure to control blood sugar levels. Thus, the development of a convenient noninvasive blood glucose monitor holds the potential to significantly reduce the morbidity and mortality associated with Diabetes. A method and apparatus for noninvasive measurement of blood glucose concentration based on transilluminated laser beam via the Index Finger has been reported in this paper. This method depends on photodiode based laser operating at 632.8 nm wavelength. During measurement, the index finger is inserted into the glucose sensing unit, the transilluminated optical signal is converted into an electrical signal, compared with the reference electrical signal, and the obtained difference signal is processed by signal processing unit which presents the results in the form of blood glucose concentration. This method would enable the monitoring blood glucose level of the diabetic patient continuously, safely and noninvasively..

  3. Application of optical lens of a CD writer for detecting the blood glucose semi-invasively

    Energy Technology Data Exchange (ETDEWEB)

    Meshram, N. D., E-mail: meshramnileshsd@gmail.com [Mathuradas Mohota College of Sciences, Nagpur-440009 (India); Dahikar, P. B., E-mail: pbdahikar@rediffmail.com [Kamla Nehru Mahavidyalaya, Sakkardara Square, Nagpur-440009 (India)

    2014-10-15

    Recent technological advancements in the photonics industry have led to a resurgence of interest in optical glucose sensing and to realistic progress toward the development of an optical glucose sensor. Such a sensor has the potential to significantly improve the quality of life for the estimated 16 million diabetics in this country by making routine glucose measurements more convenient. Currently over 100 small companies and universities are working to develop noninvasive or minimally invasive glucose sensing technologies, and optical methods play a large role in these efforts. It has become overwhelmingly clear that frequent monitoring and tight control of blood sugar levels are requisite for effective management of Diabetes mellitus and reduction of the complications associated with this disease. The pain and trouble associated with current “finger-stick” methods for blood glucose monitoring result in decreased patient compliance and a failure to control blood sugar levels. Thus, the development of a convenient noninvasive blood glucose monitor holds the potential to significantly reduce the morbidity and mortality associated with Diabetes. A method and apparatus for noninvasive measurement of blood glucose concentration based on transilluminated laser beam via the Index Finger has been reported in this paper. This method depends on photodiode based laser operating at 632.8 nm wavelength. During measurement, the index finger is inserted into the glucose sensing unit, the transilluminated optical signal is converted into an electrical signal, compared with the reference electrical signal, and the obtained difference signal is processed by signal processing unit which presents the results in the form of blood glucose concentration. This method would enable the monitoring blood glucose level of the diabetic patient continuously, safely and noninvasively.

  4. Application of optical lens of a CD writer for detecting the blood glucose semi-invasively

    International Nuclear Information System (INIS)

    Recent technological advancements in the photonics industry have led to a resurgence of interest in optical glucose sensing and to realistic progress toward the development of an optical glucose sensor. Such a sensor has the potential to significantly improve the quality of life for the estimated 16 million diabetics in this country by making routine glucose measurements more convenient. Currently over 100 small companies and universities are working to develop noninvasive or minimally invasive glucose sensing technologies, and optical methods play a large role in these efforts. It has become overwhelmingly clear that frequent monitoring and tight control of blood sugar levels are requisite for effective management of Diabetes mellitus and reduction of the complications associated with this disease. The pain and trouble associated with current “finger-stick” methods for blood glucose monitoring result in decreased patient compliance and a failure to control blood sugar levels. Thus, the development of a convenient noninvasive blood glucose monitor holds the potential to significantly reduce the morbidity and mortality associated with Diabetes. A method and apparatus for noninvasive measurement of blood glucose concentration based on transilluminated laser beam via the Index Finger has been reported in this paper. This method depends on photodiode based laser operating at 632.8 nm wavelength. During measurement, the index finger is inserted into the glucose sensing unit, the transilluminated optical signal is converted into an electrical signal, compared with the reference electrical signal, and the obtained difference signal is processed by signal processing unit which presents the results in the form of blood glucose concentration. This method would enable the monitoring blood glucose level of the diabetic patient continuously, safely and noninvasively.

  5. Comparison of glucose concentration and glucose absorption from the GI-tract in pigs in whole blood and in plasma

    DEFF Research Database (Denmark)

    Theil, Peter Kappel; Jørgensen, Henry; Larsen, Torben;

    2010-01-01

    The present investigation was undertaken to compare glucose absorption from the gastro-intestinal tract quantified in either whole blood or plasma using the arterio-venous differences and portal blood flow measurements. Pigs were surgically modified with catheters in the portal vein and the mesen......The present investigation was undertaken to compare glucose absorption from the gastro-intestinal tract quantified in either whole blood or plasma using the arterio-venous differences and portal blood flow measurements. Pigs were surgically modified with catheters in the portal vein...... and the mesenteric artery and a flow probe around the portal vein to allow assessment of nutrient absorption using Fick's principle. In Exp. 1, six sows (mean LW = 202 ± 28 kg) were fed three diets containing 517, 216 or 225 g/kg DM of starch, respectively. In Exp. 2, six female pigs (mean LW = 59 ± 2 kg) were fed...... three different diets with similar contents of starch (470-506 g/kg DM). The diets in both studies differed regarding amount and solubility of fibre. Blood samples were collected repeatedly 0-10 h after morning feeding. Glucose was measured in whole blood using a glucometer (Accu-Chek®) and in plasma...

  6. Blood glucose fluctuation accelerates renal injury involved to inhibit the AKT signaling pathway in diabetic rats.

    Science.gov (United States)

    Ying, Changjiang; Zhou, Xiaoyan; Chang, Zhenzhen; Ling, Hongwei; Cheng, Xingbo; Li, Wei

    2016-07-01

    Blood glucose fluctuation is associated with diabetic nephropathy. However, the mechanism by which blood glucose fluctuation accelerates renal injury is not fully understood. The aim of the present study was to assess the effects of blood glucose fluctuation on diabetic nephropathy in rats and investigate its underlying mechanism. Diabetes in the rats was induced by a high sugar, high-fat diet, and a single dose of STZ (35 mg/kg)-injected intraperitoneally. Unstable blood sugar models were induced by subcutaneous insulin injection and intravenous glucose injection alternately. Body weight, glycosylated hemoglobin A1c (HbAlc), blood urea nitrogen (BUN), serum creatinine (Scr), and Creatinine clearance (Ccr) were assessed. T-SOD activity and MDA level were measured by assay kit. Change in renal tissue ultrastructure was observed by light microscopy and electron microscopy. Phosphorylated ser/thr protein kinase (p-AKT) (phosphor-Ser473), phosphorylated glycogen synthase kinase-3 beta (p-GSK-3β) (phosphor-Ser9), Bcl-2-associated X protein (BAX), B cell lymphoma/leukemia 2 (BCL-2), and cleaved-cysteinyl aspartate-specific proteinase-3 (caspase-3) levels were detected by immunohistochemistry and Western blot. We observed that BUN and Scr were increased in diabetic rats, and Ccr was decreased. Furthermore, blood glucose fluctuations could exacerbate the Ccr changes. Renal tissue ultrastructure was also seriously injured by glucose variability in diabetic rats. In addition, glucose fluctuation increased the oxidative stress of renal tissue. Moreover, fluctuating blood glucose decreased p-AKT level and BCL-2, and increased p-GSK-3β, BAX, cleaved-caspase-3 levels, and ratio of BAX/BCL-2 in the kidneys of diabetic rats. In conclusion, these results suggest that blood glucose fluctuation accelerated renal injury is due, at least in part to its oxidative stress promoting and inhibiting the AKT signaling pathway in diabetic rats. PMID:26860515

  7. Effect of pertussis toxin pretreated centrally on blood glucose level induced by stress.

    Science.gov (United States)

    Suh, Hong-Won; Sim, Yun-Beom; Park, Soo-Hyun; Sharma, Naveen; Im, Hyun-Ju; Hong, Jae-Seung

    2016-09-01

    In the present study, we examined the effect of pertussis toxin (PTX) administered centrally in a variety of stress-induced blood glucose level. Mice were exposed to stress after the pretreatment of PTX (0.05 or 0.1 µg) i.c.v. or i.t. once for 6 days. Blood glucose level was measured at 0, 30, 60 and 120 min after stress stimulation. The blood glucose level was increased in all stress groups. The blood glucose level reached at maximum level after 30 min of stress stimulation and returned to a normal level after 2 h of stress stimulation in restraint stress, physical, and emotional stress groups. The blood glucose level induced by cold-water swimming stress was gradually increased up to 1 h and returned to the normal level. The intracerebroventricular (i.c.v.) or intrathecal (i.t.) pretreatment with PTX, a Gi inhibitor, alone produced a hypoglycemia and almost abolished the elevation of the blood level induced by stress stimulation. The central pretreatment with PTX caused a reduction of plasma insulin level, whereas plasma corticosterone level was further up-regulated in all stress models. Our results suggest that the hyperglycemia produced by physical stress, emotional stress, restraint stress, and the cold-water swimming stress appear to be mediated by activation of centrally located PTX-sensitive G proteins. The reduction of blood glucose level by PTX appears to due to the reduction of plasma insulin level. The reduction of blood glucose level by PTX was accompanied by the reduction of plasma insulin level. Plasma corticosterone level up-regulation by PTX in stress models may be due to a blood glucose homeostatic mechanism. PMID:27610033

  8. Resolving the sources of plasma glucose excursions following a glucose tolerance test in the rat with deuterated water and [U-13C]glucose

    NARCIS (Netherlands)

    Delgado, T.C.; Barosa, C.; Nunes, P.M.; Cerdán, S.; Geraldes, C.F.G.C.; Jones, J.G.

    2012-01-01

    Sources of plasma glucose excursions (PGE) following a glucose tolerance test enriched with [U-(13)C]glucose and deuterated water were directly resolved by (13)C and (2)H Nuclear Magnetic Resonance spectroscopy analysis of plasma glucose and water enrichments in rat. Plasma water (2)H-enrichment att

  9. Impact of time since last caloric intake on blood glucose levels.

    Science.gov (United States)

    Moebus, Susanne; Göres, Laura; Lösch, Christian; Jöckel, Karl-Heinz

    2011-09-01

    Blood glucose (BG) is usually measured after a caloric restriction of at least 8 h; however evidence-based recommendations for the duration of a fasting status are missing. Here we analyze the effect of fasting duration on levels of BG to determine the minimal fasting duration to achieve comparable BG levels to conventional fasting measurements. We used data of a cross-sectional study on primary care patients, performed in October 2005. We included 28,024 individuals (age-range 18-99 years; 63% women) without known diabetes mellitus and without missing data for BG and fasting status. We computed general linear models, adjusting for age, sex, time of blood withdrawal, systolic blood pressure, waist circumference, total- and HDL-cholesterol, physical activity, smoking, intake of beta-blocker and alcohol. We tested the intra-individual variability with respect to fasting status. Overall, the mean BG differed only slightly between individuals fasting ≥ 8 h and those fasting fasting differences of BG diminished in men to -0.08 mmol/L (95%-CI: -0.15; -0.01 mmol/L), in women to -0.07 mmol/L (-0.12; -0.03 mmol/L) compared to individuals fasting ≥ 8 h. Noteworthy, age, time of day of blood withdrawal, physical activity, and intake of hard liquor influenced BG levels considerably. Our data challenge the necessity for a fasting duration of ≥ 8 h when measuring blood glucose, suggesting a random sampling or a fasting duration of 3 h as sufficient. Rather, our study indicates that essentially more effort on the assessment of additional external/internal factors on BG levels is necessary. PMID:21822717

  10. Are Tubes Containing Sodium Fluoride Still Needed for the Measurement of Blood Glucose in Hospital Laboratory Practice?

    Directory of Open Access Journals (Sweden)

    Amira Al-Kharusi

    2014-11-01

    Full Text Available Objectives: To compare glucose values obtained using sodium flouride (NaF tubes and serum separation tubes (SST in a tertiary care hospital laboratory setting.  Methods: This study was conducted at the Clinical Biochemistry Laboratory, Royal Hospital, Oman. During the study period (1 September–30 November 2013, 50 pairs (one NaF tube and one SST of patient’s blood specimens were randomly collected. Following separation of plasma (NaF tubes and serum (SST, glucose concentrations were measured by hexokinase assay using the Architect c8000. Fifteen pairs of these tubes were kept in the refrigerator at 4°C and plasma/serum glucose concentrations were measured daily up to seven days after collection.  Results: Comparing plasma (NaF and serum (SST results of glucose values (n=50 showed an average difference of 0.00mmol/L (range -0.60 to +0.60mmol/L. Bland Altman analysis gave a non-significant constant bias of 0.10 ±0.195mmol/L (bias ±SD. Pearson correlation between plasma (NaF and serum (SST glucose concentrations revealed a significant correlation approaching unity with r2= 0.9991. No significant differences in glucose values were noted for both plasma and serum in 15 pairs of NaF and SST tubes when analyzed seven days following refrigeration. Hemolysis was observed in five (10% NaF tubes compared with two (4% SST.  Conclusion: There is no difference in glucose values collected from plasma NaF tubes or serum SST, and so SST can be used in hospital laboratory settings as there are practical advantages, including cost-effectiveness and reduction in blood volume drawn when utilizing these tubes for glucose and other tests from a single blood collection tube.

  11. Optical coherence tomography for glucose monitoring in blood

    Science.gov (United States)

    Ullah, Hafeez; Hussain, Fayyaz; Ikram, Masroor

    2015-08-01

    In this review, we have discussed the potential application of the emerging imaging modality, i.e., optical coherence tomography (OCT) for glucose monitoring in biological tissues. OCT provides monitoring of glucose diffusion in different fibrous tissues like in sclera by determining the permeability rate with acceptable accuracy both in type 1 and in type 2 diabetes. The maximum precision of glucose measurement in Intralipid suspensions, for example, with the OCT technique yields the accuracy up to 4.4 mM for 10 % Intralipid and 2.2 mM for 3 % Intralipid.

  12. Effects of blood glucose level on FDG uptake by liver: a FDG-PET/CT study

    Energy Technology Data Exchange (ETDEWEB)

    Kubota, Kazuo, E-mail: kkubota@cpost.plala.or.j [Division of Nuclear Medicine, Department of Radiology, National Center for Global Health and Medicine, Tokyo 162-8655 (Japan); Watanabe, Hiroshige; Murata, Yuji [Department of Radiology, Faculty of Medicine, Tokyo Medical and Dental University, Tokyo 113-8519 (Japan); Yukihiro, Masashi; Ito, Kimiteru; Morooka, Miyako; Minamimoto, Ryogo [Division of Nuclear Medicine, Department of Radiology, National Center for Global Health and Medicine, Tokyo 162-8655 (Japan); Hori, Ai [Department of Epidemiology and International Health, Research Institute, National Center for Global Health and Medicine, Tokyo 162-8655 (Japan); Shibuya, Hitoshi [Department of Radiology, Faculty of Medicine, Tokyo Medical and Dental University, Tokyo 113-8519 (Japan)

    2011-04-15

    In FDG-PET for abdominal malignancy, the liver may be assumed as an internal standard for grading abnormal FDG uptake both in early images and in delayed images. However, physiological variables of FDG uptake by the liver, especially the effects of blood glucose level, have not yet been elucidated. Methods: FDG-PET studies of 70 patients examined at 50 to 70 min after injection (60{+-}10 min: early images) and of 68 patients examined at 80 to 100 min after injection (90{+-}10 min: delayed images) were analyzed for liver FDG uptake. Patients having lesions in the liver, spleen and pancreas; patients having bulk tumor in other areas; and patients early after chemotherapy or radiotherapy were excluded; also, patients with blood glucose level over 125 mg/dl were excluded. Results: Mean standardized uptake value (SUV) of the liver, blood glucose level and sex showed no significant differences between early images and delayed images. However, liver SUV in the delayed image showed a larger variation than that in the early image and showed significant correlation to blood glucose level. The partial correlation coefficient between liver SUV and blood glucose level in the delayed image with adjustment for sex and age was 0.73 (P<.0001). Multivariate regression coefficient (95% confidence interval) of blood glucose was 0.017 (0.013-0.021). Conclusion: Blood glucose level is an important factor affecting the normal liver FDG uptake in nondiabetic patients. In the case of higher glucose level, liver FDG uptake is elevated especially in the delayed image. This may be due to the fact that the liver is the key organ responsible for glucose metabolism through gluconeogenesis and glycogen storage.

  13. The effects of food deprivation and incentive motivation on blood glucose levels and cognitive function.

    Science.gov (United States)

    Green, M W; Elliman, N A; Rogers, P J

    1997-11-01

    The current study investigated the relationships between blood glucose levels, mild food deprivation, sympathetic arousal, and cognitive processing efficiency. Subjects (n = 82) were randomly assigned to four experimental conditions, comprising combined manipulations of food deprivation and incentive motivation. Baseline and mid-session measurements of blood glucose, blood pressure and pulse rate were taken. Subjects completed a number of measures of cognitive processing efficiency and self report measures of affective and somatic state. Although glucose levels were lowered following food deprivation, there was no significant detrimental effect of food deprivation on task performance. However, improved recognition memory processing times were associated with deprivation. Incentive motivation was associated with faster simple reaction times and higher diastolic blood pressure. There were no significant relationships between glucose levels and task performance, further supporting the hypothesis that the brain is relatively invulnerable to short food deprivation. PMID:9399371

  14. Kinetic Parameters for the Noncatalyzed and Enzyme-Catalyzed Mutarotation of Glucose Using a Blood Glucometer

    Science.gov (United States)

    Hardee, John R.; Delgado, Bryan; Jones, Wray

    2011-01-01

    The kinetic parameters for the conversion of alpha-D-glucose to beta-D-glucose were measured using a blood glucometer. The reaction order, rate constant, and Arrhenius activation energy are reported for the noncatalyzed reaction and turnover number and Michaelis constant are reported for the reaction catalyzed by porcine kidney mutarotase. The…

  15. Influence of blood glucose on the expression of glucose transporter proteins 1 and 3 in the brain of diabetic rats

    Institute of Scientific and Technical Information of China (English)

    HOU Wei-kai; FU Chun-li; ZHANG Wen-wen; CHEN Li; XIAN Yu-xin; ZHANG Li; LAI Hong; HOU Xin-guo; XU Yu-xin; YU Ting; XU Fu-yu; SONG Jun

    2007-01-01

    Background The delivery of glucose from the blood to the brain involves its passage across the endothelial cells of the blood-brain barrier (BBB), which is mediated by the facilitative glucose transporter protein 1 (GLUT1), and then across the neural cell membranes, which is mediated by GLUT3. This study aimed to evaluate the dynamic influence of hyperglycemia on the expression of these GLUTs by measuring their expression in the brain at different blood glucose levels in a rat model of diabetes. This might help to determine the proper blood glucose threshold level in the treatment of diabetic apoplexy.Methods Diabetes mellitus was induced with streptozotocin (STZ) in 30 rats. The rats were randomly divided into 3 groups: diabetic group without blood glucose control (group DM1), diabetic rats treated with low dose insulin (group DM2),and diabetic rats treated with high dose insulin (group DM3). The mRNA and protein levels of GLUT1 and GLUT3 were assayed by reverse transcriptase-polymerase chain reaction (RT-PCR) and immunohistochemistry, respectively.Results Compared with normal control rats, the GLUT1 mRNA was reduced by 46.08%, 29.80%, 19.22% (P<0.01) in DM1, DM2, and DM3 group, respectively; and the GLUT3 mRNA was reduced by 75.00%, 46.75%, and 17.89% (P<0.01)in DM1, DM2, and DM3 group, respectively. The abundance of GLUT1 and GLUT3 proteins had negative correlation with the blood glucose level (P<0.01). The density of microvessels in the brain of diabetic rats did not change significantly compared with normal rats.Conclusions Chronic hyperglycemia downregulates GLUT1 and GLUT3 expression at both mRNA and protein levels in the rat brain, which is not due to the decrease of the density of microvessels. The downregulation of GLUT1 and GLUT3 expression might be the adaptive reaction of the body to prevent excessive glucose entering the cell that may lead to cell damage.

  16. Effects of a checklist on self-assessment of blood glucose level by a memory-impaired woman with diabetes mellitus.

    OpenAIRE

    Wong, S E; Seroka, P L; Ogisi, J

    2000-01-01

    This study evaluated effects of a checklist on the accuracy of self-assessment of blood glucose level by a diabetic woman with memory impairments caused by viral encephalitis. The checklist consisted of 54 steps for operating an electronic glucometer, which the subject performed in sequence and checked off when completed. Following introduction of the checklist, the percentage of steps completed correctly increased in simulated and actual blood glucose tests and yielded clinically useful info...

  17. Improvements on Noninvasive Blood Glucose Biosensors Using Wavelets for Quick Fault Detection

    OpenAIRE

    Germán Campetelli; David Zumoffen; Marta Basualdo

    2011-01-01

    Noninvasive blood glucose sensors are still under development stage considering that they are far from being suitable for use in anartificial pancreas. The latter has three main parts: the blood glucose sensor, the insulin pump and the controller. However, for the biosensor analyzed here, some common failures such as signal shifts and unreal picks were found. They must be taken into account, for computing the correct insulin dosage for diabetic persons. Hence, a fault det...

  18. The Health Behavior Schedule-II for Diabetes Predicts Self-Monitoring of Blood Glucose

    Science.gov (United States)

    Frank, Maxwell T.; Cho, Sungkun; Heiby, Elaine M.; Lee, Chun-I; Lahtela, Adrienne L.

    2006-01-01

    The Health Behavior Schedule-II for Diabetes (HBS-IID) is a 27-item questionnaire that was evaluated as a predictor of self-monitoring of blood glucose (SMBG). The HBS-IID was completed by 96 adults with Type 2 diabetes. Recent glycosylated hemoglobin HbA1c and fasting blood glucose results were taken from participants' medical records. Only 31.3%…

  19. Scale Space Methods for Analysis of Type 2 Diabetes Patients' Blood Glucose Values

    OpenAIRE

    Stein Olav Skrøvseth; Fred Godtliebsen

    2011-01-01

    We describe how scale space methods can be used for quantitative analysis of blood glucose concentrations from type 2 diabetes patients. Blood glucose values were recorded voluntarily by the patients over one full year as part of a self-management process, where the time and frequency of the recordings are decided by the patients. This makes a unique dataset in its extent, though with a large variation in reliability of the recordings. Scale space and frequency space techniques are suited to ...

  20. Blood Glucose Alterations in Spinal versus General anesthesia in those undergoing Cesarean Section Delivery

    OpenAIRE

    Alireza Manafi; Habibollah Zakeri; Fatemeh Salahyan; Marzieh Tavassoli; Fahimeh Shekoohi; Roya Kokabi; Sahar Khazforoosh

    2015-01-01

    Introduction: Major body injury or surgery is associated with reproducible metabolic and hormonal responses. Alteration of blood glucose levels is one of the necessary metabolic changes to surgical stress. Surgical techniques and different methods of anesthesia are factors that can help to control and balance the body’s hormones. One of the most effective ways for decline the endocrine-metabolic response is local anesthesia. We conducted this study to compare the measurement of blood glucose ...

  1. Diabetes and puberty : studies on hormonal factors of importance to the blood glucose control

    OpenAIRE

    Zachrisson, Ingmar

    2000-01-01

    It is well known that, in children with type 1 diabetes, metabolic control often deteriorates during puberty. Better understanding of the mechanisms that cause deterioration of blood glucose control can lead to improved therapeutic approaches. Preliminary observations suggest that one component of the impaired glycemic control is a large variation in blood glucose. Several of the hormonal changes during puberty affect insulin sensitivity and could, in addition to lifestyle f...

  2. How to compare adequacy of algorithms to control blood glucose in the intensive care unit?

    OpenAIRE

    Van den Berghe , Greet

    2004-01-01

    Vogelzang et al. retrospectively assessed a derivative marker of blood glucose control over time in the intensive care unit (ICU), "the hyperglycemic index" (HGI), in relation to outcome. The HGI predicted mortality better than other indices of blood glucose control that do not take the duration of hyperglycemia into account. This provided further support to the concept of maintaining normoglycemia with insulin throughout intensive care in order to improve outcome. The HGI was also proposed a...

  3. Clinical implication of blood glucose monitoring in general dental offices: the Ehime Dental Diabetes Study

    OpenAIRE

    Harase, Tadahiro; Nishida, Wataru; Hamakawa, Tomohiro; Hino, Satoshi; Shigematsu, Kenji; Kobayashi, Satoru; Sako, Hirofumi; Ito, Shirou; Murakami, Hajime; Nishida, Kei; Inoue, Hiroshi; Fujisawa, Masahito; Yoshizu, Hiroshi; Kawamura, Ryoichi; Takata, Yasunori

    2015-01-01

    Objective We examined whether general dentists can contribute to the detection of patients with undiagnosed diabetes and prediabetes by monitoring blood glucose in dental clinics. Research design and methods A total of 716 patients who visited clinics for dental treatment were enrolled and classified into 3 groups (mild, moderate, and severe) according to Kornman's criteria for periodontitis. The correlations between the casual blood glucose level, presence or absence of the history of diabet...

  4. System Accuracy Evaluation of the GlucoRx Nexus Voice TD-4280 Blood Glucose Monitoring System

    OpenAIRE

    Muhammad Khan; Keith Broadbent; Mike Morris; David Ewins; Franklin Joseph

    2014-01-01

    Use of blood glucose (BG) meters in the self-monitoring of blood glucose (SMBG) significantly lowers the risk of diabetic complications. With several BG meters now commercially available, the International Organization for Standardization (ISO) ensures that each BG meter conforms to a set degree of accuracy. Although adherence to ISO guidelines is a prerequisite for commercialization in Europe, several BG meters claim to meet the ISO guidelines yet fail to do so on internal validation. We con...

  5. Effect of Sulfonylureas Administered Centrally on the Blood Glucose Level in Immobilization Stress Model

    OpenAIRE

    Sharma, Naveen; Sim, Yun-Beom; Park, Soo-hyun; Lim, Su-Min; Kim, Sung-Su; Jung, Jun-Sub; Hong, Jae-Seung; Suh, Hong-Won

    2015-01-01

    Sulfonylureas are widely used as an antidiabetic drug. In the present study, the effects of sulfonylurea administered supraspinally on immobilization stress-induced blood glucose level were studied in ICR mice. Mice were once enforced into immobilization stress for 30 min and returned to the cage. The blood glucose level was measured 30, 60, and 120 min after immobilization stress initiation. We found that intracerebroventricular (i.c.v.) injection with 30 µg of glyburide, glipizide, glimepir...

  6. Reliable long-term continuous blood glucose monitoring for patients in critical care using microdialysis and infrared spectrometry

    Science.gov (United States)

    Heise, H. Michael; Damm, Uwe; Kondepati, Venkata R.

    2006-02-01

    For clinical research, in-vivo blood glucose monitoring is an ongoing important topic to improve glycemic control in patients with non-adequate blood glucose regulation. Critically ill patients received much interest, since the intensive insulin therapy treatment, as established for diabetics, reduces mortality significantly. Despite the existence of commercially available, mainly amperometric biosensors, continued interest is in infrared spectroscopic techniques for reagent-free glucose monitoring. For stable long-term operation, avoiding also sensor recalibration, a bed-side device coupled to a micro-dialysis probe was developed for quasi-continuous glucose monitoring. Multivariate calibration is required for glucose concentration prediction due to the complex composition of dialysates from interstitial body fluid. Measurements were carried out with different test persons, each experiment lasting for more than 8 hours. Owing to low dialysis recovery rates, glucose concentrations in the dialysates were between 0.83 and 4.44 mM. Standard errors of prediction (SEP) obtained with Partial Least Squares (PLS) calibration and different cross-validation strategies were mainly between 0.13 and 0.18 mM based on either full interval data or specially selected spectral variables.

  7. Cerebrospinal fluid ionic regulation, cerebral blood flow, and glucose use during chronic metabolic alkalosis

    Energy Technology Data Exchange (ETDEWEB)

    Schroeck, H.K.; Kuschinsky, W. (Univ. of Bonn (Germany, F.R.))

    1989-10-01

    Chronic metabolic alkalosis was induced in rats by combining a low K+ diet with a 0.2 M NaHCO3 solution as drinking fluid for either 15 or 27 days. Local cerebral blood flow and local cerebral glucose utilization were measured in 31 different structures of the brain in conscious animals by means of the iodo-(14C)antipyrine and 2-(14C)deoxy-D-glucose method. The treatment induced moderate (15 days, base excess (BE) 16 mM) to severe (27 days, BE 25 mM) hypochloremic metabolic alkalosis and K+ depletion. During moderate metabolic alkalosis no change in cerebral glucose utilization and blood flow was detectable in most brain structures when compared with controls. Cerebrospinal fluid (CSF) K+ and H+ concentrations were significantly decreased. During severe hypochloremic alkalosis, cerebral blood flow was decreased by 19% and cerebral glucose utilization by 24% when compared with the control values. The decrease in cerebral blood flow during severe metabolic alkalosis is attributed mainly to the decreased cerebral metabolism and to a lesser extent to a further decrease of the CSF H+ concentration. CSF K+ concentration was not further decreased. The results show an unaltered cerebral blood flow and glucose utilization together with a decrease in CSF H+ and K+ concentrations at moderate metabolic alkalosis and a decrease in cerebral blood flow and glucose utilization together with a further decreased CSF H+ concentration at severe metabolic alkalosis.

  8. Blood glucose regulation mechanism in depressive disorder animal model during hyperglycemic states.

    Science.gov (United States)

    Lim, Su-Min; Park, Soo-Hyun; Sharma, Naveen; Kim, Sung-Su; Lee, Jae-Ryeong; Jung, Jun-Sub; Suh, Hong-Won

    2016-06-01

    Depression is more common among diabetes people than in the general population. In the present study, blood glucose change in depression animal model was characterized by various types of hyperglycemia models such as d-glucose-fed-, immobilization stress-, and drug-induced hyperglycemia models. First, the ICR mice were enforced into chronic restraint stress for 2h daily for 2 weeks to produce depression animal model. The animals were fed with d-glucose (2g/kg), forced into restraint stress for 30min, or administered with clonidine (5μg/5μl) supraspinally or spinally to produce hyperglycemia. The blood glucose level in depression group was down-regulated compared to that observed in the normal group in d-glucose-fed-, restraint stress-, and clonidine-induced hyperglycemia models. The up-regulated corticosterone level induced by d-glucose feeding or restraint stress was reduced in the depression group while the up-regulation of plasma corticosterone level is further elevated after i.t. or i.c.v. clonidine administration in the depression group. The up-regulated insulin level induced by d-glucose feeding or restraint stress was reduced in the depression group. On the other hand, blood corticosterone level in depression group was up-regulated compared to the normal group after i.t. or i.c.v. clonidine administration. Whereas the insulin level in depression group was not altered when mice were administered clonidine i.t. or i.c.v. Our results suggest that the blood glucose level in depression group is down-regulated compared to the normal group during d-glucose-fed-, immobilization stress-, and clonidine-induced hyperglycemia in mice. The down-regulation of the blood glucose level might be one of the important pathophysiologic changes in depression.

  9. Blood glucose regulation mechanism in depressive disorder animal model during hyperglycemic states.

    Science.gov (United States)

    Lim, Su-Min; Park, Soo-Hyun; Sharma, Naveen; Kim, Sung-Su; Lee, Jae-Ryeong; Jung, Jun-Sub; Suh, Hong-Won

    2016-06-01

    Depression is more common among diabetes people than in the general population. In the present study, blood glucose change in depression animal model was characterized by various types of hyperglycemia models such as d-glucose-fed-, immobilization stress-, and drug-induced hyperglycemia models. First, the ICR mice were enforced into chronic restraint stress for 2h daily for 2 weeks to produce depression animal model. The animals were fed with d-glucose (2g/kg), forced into restraint stress for 30min, or administered with clonidine (5μg/5μl) supraspinally or spinally to produce hyperglycemia. The blood glucose level in depression group was down-regulated compared to that observed in the normal group in d-glucose-fed-, restraint stress-, and clonidine-induced hyperglycemia models. The up-regulated corticosterone level induced by d-glucose feeding or restraint stress was reduced in the depression group while the up-regulation of plasma corticosterone level is further elevated after i.t. or i.c.v. clonidine administration in the depression group. The up-regulated insulin level induced by d-glucose feeding or restraint stress was reduced in the depression group. On the other hand, blood corticosterone level in depression group was up-regulated compared to the normal group after i.t. or i.c.v. clonidine administration. Whereas the insulin level in depression group was not altered when mice were administered clonidine i.t. or i.c.v. Our results suggest that the blood glucose level in depression group is down-regulated compared to the normal group during d-glucose-fed-, immobilization stress-, and clonidine-induced hyperglycemia in mice. The down-regulation of the blood glucose level might be one of the important pathophysiologic changes in depression. PMID:27034116

  10. Diabetes Technology: Markers, Monitoring, Assessment, and Control of Blood Glucose Fluctuations in Diabetes

    Directory of Open Access Journals (Sweden)

    Boris P. Kovatchev

    2012-01-01

    Full Text Available People with diabetes face a life-long optimization problem: to maintain strict glycemic control without increasing their risk for hypoglycemia. Since the discovery of insulin in 1921, the external regulation of diabetes by engineering means has became a hallmark of this optimization. Diabetes technology has progressed remarkably over the past 50 years—a progress that includes the development of markers for diabetes control, sophisticated monitoring techniques, mathematical models, assessment procedures, and control algorithms. Continuous glucose monitoring (CGM was introduced in 1999 and has evolved from means for retroactive review of blood glucose profiles to versatile reliable devices, which monitor the course of glucose fluctuations in real time and provide interactive feedback to the patient. Technology integrating CGM with insulin pumps is now available, opening the field for automated closed-loop control, known as the artificial pancreas. Following a number of in-clinic trials, the quest for a wearable ambulatory artificial pancreas is under way, with a first prototype tested in outpatient setting during the past year. This paper discusses key milestones of diabetes technology development, focusing on the progress in the past 10 years and on the artificial pancreas—still not a cure, but arguably the most promising treatment of diabetes to date.

  11. Changes of hemoglobin content and glucose levels in the blood of Rattus norvegicus by water extracts of Azadirachta indica

    Institute of Scientific and Technical Information of China (English)

    Shori; Amal Bakr

    2012-01-01

    Presently,there is a growing interest in herbal remedies.Neem (Azadirachta indica) has been used in traditional medicine over centuries.In the present study,the effects of water extracts of Azadirachta indica seeds,stems,flowers and bark on the changes of hemoglobin content (Hb) and glucose levels in the blood of Rattus norvegicus were investigated.Different doses of A.indica water extracts of seeds,stems,flowers and bark were injected to the tested animals every 48 h for 14 days.Significant decrease in both hemoglobin content and glucose levels in the blood samples in all groups of injected rats were compared to control group.However,in all groups higher decrease was shown in the rats injected with 1 g·mL-1 ofA.indica water extracts.In addition,the present study showed no significant relationship between decreased hemoglobin content and glucose levels in blood samples,and increased doses injected.In conclusion,A.indica has the potential to decrease both hemoglobin content and blood glucose levels.

  12. Energized by love: thinking about romantic relationships increases positive affect and blood glucose levels.

    Science.gov (United States)

    Stanton, Sarah C E; Campbell, Lorne; Loving, Timothy J

    2014-10-01

    We assessed the impact of thinking of a current romantic partner on acute blood glucose responses and positive affect over a short period of time. Participants in romantic relationships were randomly assigned to reflect on their partner, an opposite-sex friend, or their morning routine. Blood glucose levels were assessed prior to reflection, as well as at 10 and 25 min postreflection. Results revealed that individuals in the routine and friend conditions exhibited a decline in glucose over time, whereas individuals in the partner condition did not exhibit this decline (rather, a slight increase) in glucose over time. Reported positive affect following reflection was positively associated with increases in glucose, but only for individuals who reflected on their partner, suggesting this physiological response reflects eustress. These findings add to the literature on eustress in relationships and have implications for relationship processes.

  13. Photoacoustic blood glucose and skin measurement based on optical scattering effect

    Science.gov (United States)

    Zhao, Zuomin; Myllyla, Risto A.

    2002-07-01

    Non-invasive blood glucose determination has been investigated by more than 100 research groups in the world during the past fifteen years. The commonly optical methods are based on the capacity of near-IR light to penetrate a few hundreds micrometers or a few millimeters into human tissue where it interacts with glucose. A change of glucose concentration may modify the optical parameters in tissue, with the result that its glucose concentration can be extracted by analyzing the received optical signals. This paper demonstrates that glucose affects on the scattering coefficient of human blood, by applying the streak camera and pulsed photoacoustic techniques; and drinking water seems also affecting on PA signal from skin surface.

  14. Development of portable health monitoring system for automatic self-blood glucose measurement

    Science.gov (United States)

    Kim, Huijun; Mizuno, Yoshihumi; Nakamachi, Eiji; Morita, Yusuke

    2010-02-01

    In this study, a new HMS (Health Monitoring System) device is developed for diabetic patient. This device mainly consists of I) 3D blood vessel searching unit and II) automatic blood glucose measurement (ABGM) unit. This device has features such as 1)3D blood vessel location search 2) laptop type, 3) puncturing a blood vessel by using a minimally invasive micro-needle, 4) very little blood sampling (10μl), and 5) automatic blood extraction and blood glucose measurement. In this study, ABGM unit is described in detail. It employs a syringe type's blood extraction mechanism because of its high accuracy. And it consists of the syringe component and the driving component. The syringe component consists of a syringe itself, a piston, a magnet, a ratchet and a micro-needle whose inner diameter is about 80μm. And the syringe component is disposable. The driving component consists of body parts, a linear stepping motor, a glucose enzyme sensor and a slider for accurate positioning control. The driving component has the all-in-one mechanism with a glucose enzyme sensor for compact size and stable blood transfer. On designing, required thrust force to drive the slider is designed to be greater than the value of the blood extraction force. Further, only one linear stepping motor is employed for blood extraction and transportation processes. The experimental result showed more than 80% of volume ratio under the piston speed 2.4mm/s. Further, the blood glucose was measured successfully by using the prototype unit. Finally, the availability of our ABGM unit was confirmed.

  15. The associations of a marine diet with plasma lipids, blood glucose, blood pressure and obesity among the inuit in Greenland

    DEFF Research Database (Denmark)

    Bjerregaard, P; Pedersen, H S; Mulvad, G

    2000-01-01

    OBJECTIVE: To analyse the associations between the intake of fish and marine mammals and risk factors for cardiovascular disease, ie lipid profile, fasting blood glucose, blood pressure and obesity, in a population whose average consumption of n-3 fatty acids is high compared with Western countries...... was positively associated with serum high-density lipoprotein (HDL) and blood glucose and inversely with very-low-density lipoprotein (VLDL) and triglyceride. Association with low-density lipoprotein (LDL), diastolic and systolic blood pressure, waist-hip ratio and body mass index were inconsistent...... and not statistically significant. The pattern was similar within groups with low, medium and high consumption of marine food. CONCLUSIONS: There are statistically significant associations between the consumption of marine food and certain lipid fractions in the blood also in this population with a very high average...

  16. Paper membrane-based SERS platform for the determination of glucose in blood samples.

    Science.gov (United States)

    Torul, Hilal; Çiftçi, Hakan; Çetin, Demet; Suludere, Zekiye; Boyacı, Ismail Hakkı; Tamer, Uğur

    2015-11-01

    In this report, we present a paper membrane-based surface-enhanced Raman scattering (SERS) platform for the determination of blood glucose level using a nitrocellulose membrane as substrate paper, and the microfluidic channel was simply constructed by wax-printing method. The rod-shaped gold nanorod particles were modified with 4-mercaptophenylboronic acid (4-MBA) and 1-decanethiol (1-DT) molecules and used as embedded SERS probe for paper-based microfluidics. The SERS measurement area was simply constructed by dropping gold nanoparticles on nitrocellulose membrane, and the blood sample was dropped on the membrane hydrophilic channel. While the blood cells and proteins were held on nitrocellulose membrane, glucose molecules were moved through the channel toward the SERS measurement area. Scanning electron microscopy (SEM) was used to confirm the effective separation of blood matrix, and total analysis is completed in 5 min. In SERS measurements, the intensity of the band at 1070 cm(-1) which is attributed to B-OH vibration decreased depending on the rise in glucose concentration in the blood sample. The glucose concentration was found to be 5.43 ± 0.51 mM in the reference blood sample by using a calibration equation, and the certified value for glucose was 6.17 ± 0.11 mM. The recovery of the glucose in the reference blood sample was about 88 %. According to these results, the developed paper-based microfluidic SERS platform has been found to be suitable for use for the detection of glucose in blood samples without any pretreatment procedure. We believe that paper-based microfluidic systems may provide a wide field of usage for paper-based applications.

  17. Effects of Zinc Supplementation on the Anthropometric Measurements, Lipid Profiles and Fasting Blood Glucose in the Healthy Obese Adults

    Directory of Open Access Journals (Sweden)

    Sepide Mahluji

    2013-02-01

    Full Text Available Purpose: The aim of this study was to assess the effects of zinc supplementation on anthropometric measures, improving lipid profile biomarkers, and fasting blood glucose level in obese people. Methods: This randomized, double- blind clinical trial was carried out on 60 obese participants in the 18-45 age range for one month. The participants were randomly divided into the intervention group, who received 30 mg/d zinc gluconate, and the placebo group who received 30mg/d starch. Anthropometric measurements (body mass index (BMI, weight and waist circumference were recorded before and at the end of study. Lipid profile biomarkers and fasting blood glucose were determined using enzymatic procedure. Analysis of Covariance (ANCOVA test was run to compare the post-treatment values of the two groups, and t-test was conducted to compare within group changes. Results: Serum zinc concentration was increased significantly in intervention group (p=0.024. BMI and body weight was significantly decreased (p=0.030 and p=0.020, respectively. Lipid profile biomarkers and fating blood glucose did not change significantly but triglyceride level was significantly decreased (p=0.006 in the intervention group. Conclusion: The obtained results indicate that zinc supplementation improves BMI, body weight, and triglyceride concentration without considerable effects on lipid profile and glucose level. Zinc can be suggested as a suitable supplementation therapy for obese people, but more studies are needed to verify the results.

  18. Aqueous extract ofOcimum tenuiflorum decreases levels of blood glucose in induced hyperglycemic tilapia (Oreochromis niloticus)

    Institute of Scientific and Technical Information of China (English)

    Amilcar Arenal; Leonardo Martn; Nestor M Castillo; Dainier de la Torre; Ubaldo Torres; Reinaldo Gonzlez

    2012-01-01

    Objective:To evaluate, in hyperglycemic tilapia [Oreochromis niloticus (O. niloticus)], the effect of this aqueous extract on blood glucose levels.Methods:The hyperglycemia inO. niloticus was induced by adding glucose to fish pond water.An aqueous extract ofOcimum tenuiflorum (O. tenuiflorum) was prepared by boiling fresh leaves and the doses of0,40,80,200 and400 mg per liter of pond water were tested.Results:The blood sugar concentration for tilapia with hyperglycemic induced was an average of50% higher than the control group.The blood glucose levels in tilapia after the induction of hyperglycemia were higher than the control group for 90 min after the treatment.The treatment with the aqueous extract ofO. tenuiflorum dropped the serum glucose level of hyperglycemic tilapia until it was similar to that of the control group and was dose dependent.Conclusions:The results indicated that O. tenuiflorum was endowed with anti-hyperglycemic activity.To our knowledge, this is the first report on the use of fish as a diabetes model to test natural extracts from plants.

  19. Stochastic and Optimization Programming for Blood Glucose & Insulin Regulatory Systems of Type-2 Diabetes

    Directory of Open Access Journals (Sweden)

    P. Tirupathi Rao

    2012-11-01

    Full Text Available In this paper a stochastic modeling and optimization problem is developed for blood glucose and insulin regulatory system suitable for management of type-2 diabetes patients. The rates of arrival and consumption of glucose and insulin in the blood are assumed as Poisson parameters and developed a model through stochastic processes. A stochastic programming problem for maintaining the optimized glucose and insulin levels of the blood is developed. An objective function for maximizing the energy release subject to the constraints on the consumption of glucose is formulated. Sensitivity analysis was carried out and observed the model behaviour through influencing parameters. Enhancing the developed programming problem as desk top automation system will make this work more accessible to the decision makers of Health care industry.

  20. Continuous monitoring of blood glucose in the practice of endocrinologist

    Directory of Open Access Journals (Sweden)

    Yu I Philippov

    2012-12-01

    Full Text Available Continuous glucose monitoring - an important diagnostic, teaching and treatment tool for patients with diabetes mellitus, which is increasingly becoming a part of routine clinical practice in endocrinology. This article presents an overview of modern techniques, their advantages and disadvantages, evidence basis and place in everyday clinical practice. The article discusses the key factors affecting the efficiency, indications, contraindications, conditions of use of the continuous glucose monitoring systems in patients with diabetes mellitus, gives an algorithm for the application of this technique in clinical practice.

  1. Comparison of a Point-of-Care Glucometer and a Laboratory Autoanalyzer for Measurement of Blood Glucose Concentrations in Domestic Pigeons ( Columba livia domestica).

    Science.gov (United States)

    Mohsenzadeh, Mahdieh Sadat; Zaeemi, Mahdieh; Razmyar, Jamshid; Azizzadeh, Mohammad

    2015-09-01

    Biochemical analysis is necessary for diagnosis and monitoring of diseases in birds; however, the small volume of blood that can be safely obtained from small avian species often limits laboratory diagnostic testing. Consequently, a suitable methodology requiring only a small volume of blood must be used. This study was designed to compare blood glucose concentrations in domestic pigeons ( Columba livia domestica) as measured by a commercial, handheld, human glucometer and a standard autoanalyzer. During the first phase of the study, whole blood samples obtained from 30 domestic pigeons were used to measure the blood glucose concentration with a glucometer, the packed cell volume (PCV), and the total erythrocyte count (nRBC). Plasma separated from the each sample was then used to obtain the plasma glucose concentration with the autoanalyzer. During the second phase of the study, 30 pigeons were assigned to 2 equal groups (n = 15). Hypoglycemia or hyperglycemia was induced in each group by intravenous injection of insulin or glucose, respectively. Blood was collected and processed, and glucose concentrations, PCV, and nRBC were measured as previously described. Linear-regression models demonstrated a significant relationship between results measured by the glucometer and autoanalyzer results from normoglycemic (correlation coefficient [R] = 0.43, P = .02), hypoglycemic (R = 0.95; P < .001), and hyperglycemic (R = 0.81; P < .001) birds. The results of this study suggest that we can predict the real blood-glucose concentration of pigeons by using results obtained by a glucometer.

  2. A comparison of fasting plasma glucose and glucose challenge test for screening of gestational diabetes mellitus.

    Science.gov (United States)

    Poomalar, G K; Rangaswamy, V

    2013-07-01

    Glucose challenge test (GCT) has been used as an effective screening test for gestational diabetes mellitus (GDM), though it has its own limitations. Hence, we assessed the effectiveness of fasting plasma glucose (FPG) as a simpler alternative procedure. A prospective study was done in 500 pregnant women with gestational age between 22 and 37 weeks. FPG, GCT and GTT were performed in all patients using the glucose oxidase/peroxidase method. The overall sensitivity and specificity of GCT were 75.0% and 92.0%, respectively and the corresponding values for FPG were 88.8% and 95.2%. The positive predictive value and negative predictive value were 42.2% and 97.9% for GCT and 59.2% and 99.1% for FPG, respectively. We conclude that FPG can be used as an effective screening tool for gestational diabetes mellitus.

  3. A tripeptide Diapin effectively lowers blood glucose levels in male type 2 diabetes mice by increasing blood levels of insulin and GLP-1.

    Directory of Open Access Journals (Sweden)

    Jifeng Zhang

    Full Text Available The prevalence of type 2 diabetes (T2D is rapidly increasing worldwide. Effective therapies, such as insulin and Glucagon-like peptide-1 (GLP-1, require injections, which are costly and result in less patient compliance. Here, we report the identification of a tripeptide with significant potential to treat T2D. The peptide, referred to as Diapin, is comprised of three natural L-amino acids, GlyGlyLeu. Glucose tolerance tests showed that oral administration of Diapin effectively lowered blood glucose after oral glucose loading in both normal C57BL/6J mice and T2D mouse models, including KKay, db/db, ob/ob mice, and high fat diet-induced obesity/T2D mice. In addition, Diapin treatment significantly reduced casual blood glucose in KKay diabetic mice in a time-dependent manner without causing hypoglycemia. Furthermore, we found that plasma GLP-1 and insulin levels in diabetic models were significantly increased with Diapin treatment compared to that in the controls. In summary, our findings establish that a peptide with minimum of three amino acids can improve glucose homeostasis and Diapin shows promise as a novel pharmaceutical agent to treat patients with T2D through its dual effects on GLP-1 and insulin secretion.

  4. Tunable laser diode system for noninvasive blood glucose measurements.

    Science.gov (United States)

    Olesberg, Jonathon T; Arnold, Mark A; Mermelstein, Carmen; Schmitz, Johannes; Wagner, Joachim

    2005-12-01

    Optical sensing of glucose would allow more frequent monitoring and tighter glucose control for people with diabetes. The key to a successful optical noninvasive measurement of glucose is the collection of an optical spectrum with a very high signal-to-noise ratio in a spectral region with significant glucose absorption. Unfortunately, the optical throughput of skin is low due to absorption and scattering. To overcome these difficulties, we have developed a high-brightness tunable laser system for measurements in the 2.0-2.5 microm wavelength range. The system is based on a 2.3 microm wavelength, strained quantum-well laser diode incorporating GaInAsSb wells and AlGaAsSb barrier and cladding layers. Wavelength control is provided by coupling the laser diode to an external cavity that includes an acousto-optic tunable filter. Tuning ranges of greater than 110 nm have been obtained. Because the tunable filter has no moving parts, scans can be completed very quickly, typically in less than 10 ms. We describe the performance of the present laser system and avenues for extending the tuning range beyond 400 nm. PMID:16390586

  5. Quality assessment of patients’ self-monitoring of blood glucose in community pharmacies

    Directory of Open Access Journals (Sweden)

    Kjome RL

    2010-03-01

    Full Text Available Objective: To evaluate diabetes patients’ self-monitoring of blood glucose using a community pharmacy-based quality assurance procedure, to investigate whether the procedure improved the quality of the patient performance of self monitoring of blood glucose, and to examine the opinions of the patients taking part in the study. Methods: The results of patient blood glucose measurements were compared to the results obtained with HemoCue Glucose 201+ by pharmacy employees in 16 Norwegian community pharmacies. Patient performance was monitored using an eight item checklist. Patients whose blood glucose measurements differed from pharmacy measurements by more than 20% were instructed in the correct use of their glucometer. The patients then re-measured their blood glucose. If the results were still outside the set limits, the control procedure was repeated with a new lot of glucometer strips, and then with a new glucometer. The patients returned for a follow-up visit after three months. Results: During the first visit, 5% of the 338 patients had measurements that deviated from pharmacy blood glucose values by more than 20% and user errors were observed for 50% of the patients. At the second visit, there was no significant change in the analytical quality of patient measurements, but the percentage of patients who made user errors had decreased to 29% (p < 0.001. Eighty-five percent of the patients reported that they used their blood glucose results to adjust medication, exercise or meals. Fifty-one percent of the patients reported a greater trust in their measurements after the second visit. Eighty percent of patients wished to have their measurements assessed yearly. Of these patients, 83% preferred to have the assessment done at the community pharmacy. Conclusion: A community pharmacy-based quality assessment procedure of patients’ self monitoring of blood glucose significantly reduced the number of user errors. The analytical quality of the

  6. Study on optical measurement conditions for noninvasive blood glucose sensing

    Science.gov (United States)

    Xu, Kexin; Chen, Wenliang; Jiang, Jingying; Qiu, Qingjun

    2004-05-01

    Utilizing Near-infrared Spectroscopy for non-invasive glucose concentration sensing has been a focusing topic in biomedical optics applications. In this paper study on measuring conditions of spectroscopy on human body is carried out and a series of experiments on glucose concentration sensing are conducted. First, Monte Carlo method is applied to simulate and calculate photons" penetration depth within skin tissues at 1600 nm. The simulation results indicate that applying our designed optical probe, the detected photons can penetrate epidermis of the palm and meet the glucose sensing requirements within the dermis. Second, we analyze the influence of the measured position variations and the contact pressure between the optical fiber probe and the measured position on the measured spectrum during spectroscopic measurement of a human body. And, a measurement conditions reproduction system is introduced to enhance the measurement repeatability. Furthermore, through a series of transmittance experiments on glucose aqueous solutions sensing from simple to complex we found that though some absorption variation information of glucose can be obtained from measurements using NIR spectroscopy, while under the same measuring conditions and with the same modeling method, choices toward measured components reduce when complication degree of components increases, and this causes a decreased prediction accuracy. Finally, OGTT experiments were performed, and a PLS (Partial Least Square) mathematical model for a single experiment was built. We can easily get a prediction expressed as RMSEP (Root Mean Square Error of Prediction) with a value of 0.5-0.8mmol/dl. But the model"s extended application and reliability need more investigation.

  7. Correlation of salivary glucose, blood glucose and oral candidal carriage in the saliva of type 2 diabetics: A case-control study

    OpenAIRE

    Satish Kumar; Padmashree, S.; Rema Jayalekshmi

    2014-01-01

    Objectives: To study the correlation between blood glucose levels and salivary glucose levels in type 2 diabetic patients, to study the relationship between salivary glucose levels and oral candidal carriage in type 2 diabetic patients and to determine whether salivary glucose levels could be used as a noninvasive tool for the measurement of glycemic control in type 2 diabetics. Study Design: The study population consisted of three groups: Group 1 consisted of 30 controlled diabetics and Grou...

  8. Effect of mitiglinide combined laser photocoagulation on blood glucose, blood lipid and vascular endothelial function in diabetic retinopathy

    Institute of Scientific and Technical Information of China (English)

    Yun-Yan Fan; Gui-Jun Luo

    2016-01-01

    Objective:To observe the effect of mitiglinide combined laser photocoagulation on blood glucose, blood lipid and vascular endothelial function in diabetic retinopathy.Methods:A total of 106 patients with diabetic retinopathy treated in our hospital from January 2014 to January 2015 were selected and assigned into the separate group and combined group. Fifty-three patients in the separate group only received oral mitiginide, while other 53 patients in the combined group received oral mitiglinide and laster photocoagulation surgery. Before and after treatment, the FBG, 2hPBG, HbA1c, TC, TG, HDL-C, LDL-C, ET-1, VEGF, PEDF, ICAM-1, FMD of patients in the two groups were analyzed.Results: After treatment, the blood glucose and blood lipid indexes of patients in the two groups were improved significantly, and there was no statistical difference between the two groups. The ET-1, ICAM-1 and VEGF of patients in the two groups decreased, and the decrease of the combined group was more distinctly. The PEDF and FMD in the two groups all increased, and the combined group changed more obviously. The regression of the blood vessel and the recovery of visual acuity in the combined group were better than the separate group.Conclusions:Mitiglinide combined with laser photocoagulation can effectively improve the level of blood glucose and blood lipid, promote vascular endothelial function and inhibit the formation of retinal neovascularization so as to improve the visual acuity level.

  9. The Coupling of Cerebral Metabolic Rate of Glucose and Cerebral Blood Flow In Vivo

    DEFF Research Database (Denmark)

    Hasselbalch, Steen; Paulson, Olaf Bjarne

    2012-01-01

    The energy supplied to the brain by metabolic substrate is largely utilized for maintaining synaptic transmission. In this regulation cerebral blood flow and glucose consumption is tightly coupled as well in the resting condition as during activation. Quantification of cerebral blood flow...... and metabolism was originally performed using the Kety-Schmidt method and this method still represent the gold standard by which subsequent methods have been evaluated. However, in its classical setting, the method overestimates cerebral blood flow. Studies of metabolic changes during activation must take...... difficulties due to limitation in resolution and partial volume effects. In contrast to the tight coupling between regional glucose metabolism and cerebral blood flow, there is an uncoupling between flow and oxygen consumption as the latter only increases to a limited extend. The excess glucose uptake is thus...

  10. Determination of total creatine kinase activity in blood serum using an amperometric biosensor based on glucose oxidase and hexokinase.

    Science.gov (United States)

    Kucherenko, I S; Soldatkin, O O; Lagarde, F; Jaffrezic-Renault, N; Dzyadevych, S V; Soldatkin, A P

    2015-11-01

    Creatine kinase (CK: adenosine-5-triphosphate-creatine phosphotransferase) is an important enzyme of muscle cells; the presence of a large amount of the enzyme in blood serum is a biomarker of muscular injuries, such as acute myocardial infarction. This work describes a bi-enzyme (glucose oxidase and hexokinase based) biosensor for rapid and convenient determination of CK activity by measuring the rate of ATP production by this enzyme. Simultaneously the biosensor determines glucose concentration in the sample. Platinum disk electrodes were used as amperometric transducers. Glucose oxidase and hexokinase were co-immobilized via cross-linking with BSA by glutaraldehyde and served as a biorecognition element of the biosensor. The biosensor work at different concentrations of CK substrates (ADP and creatine phosphate) was investigated; optimal concentration of ADP was 1mM, and creatine phosphate - 10 mM. The reproducibility of the biosensor responses to glucose, ATP and CK during a day was tested (relative standard deviation of 15 responses to glucose was 2%, to ATP - 6%, to CK - 7-18% depending on concentration of the CK). Total time of CK analysis was 10 min. The measurements of creatine kinase in blood serum samples were carried out (at 20-fold sample dilution). Twentyfold dilution of serum samples was chosen as optimal for CK determination. The biosensor could distinguish healthy and ill people and evaluate the level of CK increase. Thus, the biosensor can be used as a test-system for CK analysis in blood serum or serve as a component of multibiosensors for determination of important blood substances. Determination of activity of other kinases by the developed biosensor is also possible for research purposes. PMID:26452867

  11. Fecal Occult Blood Test and Fecal Immunochemical Test

    Science.gov (United States)

    ... Visit Global Sites Search Help? Fecal Occult Blood Test and Fecal Immunochemical Test Share this page: Was this page helpful? Also ... Test Common Questions Ask Us Related Pages The Test How is it used? When is it ordered? ...

  12. The Role of Untimed Blood Glucose in Screening for Gestational Diabetes Mellitus in a High Prevalent Diabetic Population

    Directory of Open Access Journals (Sweden)

    Sarah Cuschieri

    2016-01-01

    Full Text Available Global prevalence increase of diabetes type 2 and gestational diabetes (GDM has led to increased awareness and screening of pregnant women for GDM. Ideally screening for GDM should be done by an oral glucose tolerance test (oGTT, which is laborious and time consuming. A randomized glucose test incorporated with anthropomorphic characteristics may be an appropriate cost-effective combined clinical and biochemical screening protocol for clinical practice as well as cutting down on oGTTs. A retrospective observational study was performed on a randomized sample of pregnant women who required an OGTT during their pregnancy. Biochemical and anthropomorphic data along with obstetric outcomes were statistically analyzed. Backward stepwise logistic regression and receiver operating characteristics curves were used to obtain a suitable predictor for GDM without an oGTT and formulate a screening protocol. Significant GDM predictive variables were fasting blood glucose (p=0.0001 and random blood glucose (p=0.012. Different RBG and FBG cutoff points with anthropomorphic characteristics were compared to carbohydrate metabolic status to diagnose GDM without oGTT, leading to a screening protocol. A screening protocol incorporating IADPSG diagnostic criteria, BMI, and different RBG and FBG criteria would help predict GDM among high-risk populations earlier and reduce the need for oGTT test.

  13. Effect of commercial rye whole-meal bread on postprandial blood glucose and gastric emptying in healthy subjects

    Directory of Open Access Journals (Sweden)

    Darwich Gassan

    2009-06-01

    Full Text Available Abstract Background The intake of dietary fibre has been shown to reduce the risk of developing diabetes mellitus. The aim of this study was to compare the effects of commercial rye whole-meal bread containing whole kernels and white wheat bread on the rate of gastric emptying and postprandial glucose response in healthy subjects. Methods Ten healthy subjects took part in a blinded crossover trial. Blood glucose level and gastric emptying rate (GER were determined after the ingestion of 150 g white wheat bread or 150 g whole-meal rye bread on two different occasions after fasting overnight. The GER was measured using real-time ultrasonography, and was calculated as the percentage change in antral cross-sectional area 15 and 90 minutes after completing the meal. Results No statistically significant difference was found between the GER values or the blood glucose levels following the two meals when evaluated with the Wilcoxon signed rank sum test. Conclusion The present study revealed no difference in postprandial blood glucose response or gastric emptying after the ingestion of rye whole-meal bread compared with white wheat bread. Trial registration NCT00779298

  14. A sodium-glucose co-transporter 2 inhibitor empagliflozin prevents abnormality of circadian rhythm of blood pressure in salt-treated obese rats.

    Science.gov (United States)

    Takeshige, Yui; Fujisawa, Yoshihide; Rahman, Asadur; Kittikulsuth, Wararat; Nakano, Daisuke; Mori, Hirohito; Masaki, Tsutomu; Ohmori, Koji; Kohno, Masakazu; Ogata, Hiroaki; Nishiyama, Akira

    2016-06-01

    Studies were performed to examine the effects of the selective sodium-glucose co-transporter 2 (SGLT2) inhibitor empagliflozin on urinary sodium excretion and circadian blood pressure in salt-treated obese Otsuka Long Evans Tokushima Fatty (OLETF) rats. Fifteen-week-old obese OLETF rats were treated with 1% NaCl (in drinking water), and vehicle (0.5% carboxymethylcellulose, n=10) or empagliflozin (10 mg kg(-1)per day, p.o., n=11) for 5 weeks. Blood pressure was continuously measured by telemetry system. Glucose metabolism and urinary sodium excretion were evaluated by oral glucose tolerance test and high salt challenge test, respectively. Vehicle-treated OLETF rats developed non-dipper type blood pressure elevation with glucose intolerance and insulin resistance. Compared with vehicle-treated animals, empagliflozin-treated OLETF rats showed an approximately 1000-fold increase in urinary glucose excretion and improved glucose metabolism and insulin resistance. Furthermore, empagliflozin prevented the development of blood pressure elevation with normalization of its circadian rhythm to a dipper profile, which was associated with increased urinary sodium excretion. These data suggest that empagliflozin elicits beneficial effects on both glucose homeostasis and hypertension in salt-replete obese states. PMID:26818652

  15. Blood Glucose Levels and Performance in a Sports Camp for Adolescents with Type 1 Diabetes Mellitus: A Field Study

    OpenAIRE

    Dylan Kelly; Hamilton, Jill K.; Michael C Riddell

    2010-01-01

    Background. Acute hypo- and hyperglycemia causes cognitive and psychomotor impairment in individuals with type 1 diabetes mellitus (T1DM) that may affect sports performance. Objective. To quantify the effect of concurrent and antecedent blood glucose concentrations on sports skills and cognitive performance in youth with T1DM attending a sports camp. Design/Methods. 28 youth (ages 6–17 years) attending a sports camp carried out multiple skill-based tests (tennis, basketball, or soccer skills)...

  16. Patient self-monitoring of blood glucose and refinements of conventional insulin treatment.

    Science.gov (United States)

    Tattersall, R; Gale, E

    1981-01-01

    The compelling evidence that blood glucose control will slow or prevent microvascular complications has stimulated research to find better ways of managing insulin-dependent diabetes. The excellent results obtained with "open loop" insulin infusion systems suggest that the relative failure of conventional treatment is the result of (1) a lack of appropriate feedback to the patient and (2) the use of insulin regimens which do not mimic physiologic insulinemia, particularly in the basal state. Doctors regard blood glucose measurements as an essential part of diabetic management and extension of this technology to patients has added a new dimension, particularly in the assessment of control. Nevertheless, home blood-glucose monitoring will not necessarily improve diabetic control; the best results have been obtained when it has been offered as part of a package deal which includes more investment of time and interest by patients and doctor together with joint discussions of problems and changes in treatment. The biggest problem with conventional twice daily insulin regimens is to sustain constant basal insulin levels during the night. Attempts to obtain fasting normoglycemia with an injection before supper often result in nocturnal hyperinsulinemia and hypoglycemia. This can usually be resolved by changing to a three times daily regimen with an extra injection of NPH insulin at bedtime. Three times daily insulin injections with feedback from home blood-glucose monitoring give as good blood glucose control as infusion systems and are cheaper and more acceptable to patients. PMID:7006390

  17. How Effective is Swedish Massage on Blood Glucose Level in Children with Diabetes Mellitus?

    Directory of Open Access Journals (Sweden)

    Firoozeh Sajedi

    2011-09-01

    Full Text Available "nThis study was conducted to determine the effect of Swedish massage on blood glucose level in children with diabetes mellitus (DM. It was prospective randomized controlled trial study that conducted on 36 children, 6-12 years old with DM, recruited from a hospital in Qom City, Iran. The children were randomly assigned to intervention and control groups. Swedish massage was performed 15 minutes, 3 times a week, for 3 months in intervention group. The blood glucose levels were evaluated immediately after every session of massage in two groups. The mean ages of children in the intervention (n=18 and control (n=18 groups were 9.05 ± 1.55 and 9.83 ±2.03 years respectively. There was statistically no significant difference in blood glucose levels before intervention between two groups (P=0.586, but the blood glucose levels were lower significantly in intervention group in comparison with control group after intervention (P<0.0001. Addition of Swedish massage to daily routines; exercise, diet and medication regimens, is an effective intervention to reduce blood glucose level in diabetic children.

  18. A novel automated discontinuous venous blood monitoring system for ex vivo glucose determination in humans.

    Science.gov (United States)

    Schaller, R; Feichtner, F; Köhler, H; Bodenlenz, M; Plank, J; Wutte, A; Mader, J K; Ellmerer, M; Hellmich, R; Wedig, H; Hainisch, R; Pieber, T R; Schaupp, L

    2009-03-15

    Intensive insulin therapy reduces mortality and morbidity in critically ill patients but imposes great demands on medical staff who must take frequent blood samples for the determination of glucose levels. A solution to this resourcing problem would be provided by an automated blood monitoring system. The aim of the present clinical study was to evaluate such a system comprising an automatic blood sampling unit linked to a glucose biosensor. Our approach was to determine the correlation and system error of the sampling unit alone and of the combined system with respect to reference levels over 12h in humans. Two venous cannulae were inserted to connect the automatic and reference systems to the subjects. Blood samples were taken at 15 and 30 min intervals. The median Pearson coefficient of correlation between manually and automatically withdrawn blood samples was 0.982 for the sampling unit alone and 0.950 for the complete system. The biosensor had a linear range up to 20 mmoll(-1) and a 95% response time of Titration Error Grid analysis suggested an acceptable treatment in 99.56% of cases. Implementation of a "Keep Vein Open" saline infusion into the automated blood sampling system reduced blood withdrawal failures through occluded catheters fourfold. In summary, automated blood sampling from a peripheral vein coupled with automatic glucose determination is a promising alternative to frequent manual blood sampling. PMID:19135351

  19. The fluctuation of blood glucose, insulin and glucagon concentrations before and after insulin therapy in type 1 diabetes

    Science.gov (United States)

    Arif, Idam; Nasir, Zulfa

    2015-09-01

    A dynamical-systems model of plasma glucose, insulin and glucagon concentrations has been developed to investigate the effects of insulin therapy on blood glucose, insulin and glucagon regulations in type 1 diabetic patients. Simulation results show that the normal regulation of blood glucose concentration depends on insulin and glucagon concentrations. On type 1 diabetic case, the role of insulin on regulating blood glucose is not optimal because of the destruction of β cells in pancreas. These β cells destructions cause hyperglycemic episode affecting the whole body metabolism. To get over this, type 1 diabetic patients need insulin therapy to control the blood glucose level. This research has been done by using rapid acting insulin (lispro), long-acting insulin (glargine) and the combination between them to know the effects of insulin therapy on blood glucose, insulin and glucagon concentrations. Simulation results show that these different types of insulin have different effects on blood glucose concentration. Insulin therapy using lispro shows better blood glucose control after consumption of meals. Glargin gives better blood glucose control between meals and during sleep. Combination between lispro and glargine shows better glycemic control for whole day blood glucose level.

  20. Influence of urea on the glucose measurement by electrocatalytic sensor in the extracorporeal blood circulation of a sheep.

    Science.gov (United States)

    Saeger, S; Preidel, W; von Lucadou, I; Ruprecht, L; Lager, W

    1991-01-01

    In an animal experiment with the electrocatalytic glucose sensor, measurements were carried out over one week in the extracorporeal circulation of a sheep. Glucose tolerance tests were performed, and the influence of increased urea concentrations in the blood on the glucose determination was investigated. The sensor constructed as a flow-through cell was integrated via a vascular graft outside the body into the carotid artery of the animal and activated by an external electronic unit of measurement. The glucose concentration was determined by measuring the impedance of the electrode/membrane system at various potentials. By means of a subsequent correlation analysis of the measured values obtained over one week, a calibration valid for the entire measurement period was established. After a zero adjustment, it was even possible to adopt the calibration from the glucose measurement of the preceding animal experiment. The investigations of the influence of urea on the glucose measurement showed that the error in measurement of the sensor, which is 20% on average, is only insignificantly increased when the urea level is raised beyond the maximum physiological concentration. PMID:1759967

  1. Dextrose in the banked blood products does not seem to affect the blood glucose levels in patients undergoing liver transplantation

    Institute of Scientific and Technical Information of China (English)

    Kwok-Wai Cheng; King-Wah Chiu; Shih-Hor Wang; Chih-Che Lin; Tsan-Shiun Lin; Yueh-Wei Liu; Bruno Jawan; Chao-Long Chen; Yu-Fan Cheng; Chia-chih Tseng; Chih-Hsien Wang; Yaw-Sen Chen; Chih-Chi Wang; Tung Liang Huang; Hock-Liew Eng

    2005-01-01

    AIM: Hyperglycemia commonly seen in liver transplantation (LT) has often been attributed to the dextrose in the storage solution of blood transfusion products. The purpose of the study is to compare the changes of the blood glucose levels in transfused and non-transfused patients during LT. METHODS: A retrospective study on 60 biliary pediatric patients and 16 adult patients undergoing LT was carried out. Transfused pediatric patients were included in Group Ⅰ (GI), those not transfused in Group Ⅱ (GⅡ). Twelve adult patients were not given transfusion and assigned to Group Ⅲ (GⅢ); whereas, four adult patients who received massive transfusion were assigned to Group Ⅳ (GⅣ). The blood glucose levels, volume of blood transfused, and the volume of crystalloid infused were recorded, compared and analyzed. RESULTS: Results showed that the changes in bloodglucose levels during LT for both non-transfused and minimally transfused pediatric groups and non-transfused and massively-transfused adult groups were almost the same. CONCLUSION: We conclude that blood transfusion does not cause significant changes in the blood glucose levels inthis study.

  2. Lack of correlation of glucose levels in filtered blood plasma to density and conductivity measurements.

    Science.gov (United States)

    Gordon, David M; Ash, Stephen R

    2009-01-01

    The purpose of this research project was to determine whether the glucose level of a blood plasma sample from a diabetic patient could be predicted by measuring the density and conductivity of ultrafiltrate of plasma created by a 30,000 m.w. cutoff membrane. Conductivity of the plasma filtrate measures electrolyte concentration and should correct density measurements for changes in electrolytes and water concentration. In vitro studies were performed measuring conductivity and density of solutions of varying glucose and sodium chloride concentrations. Plasma from seven hospitalized patients with diabetes was filtered across a 30,000 m.w. cutoff membrane. The filtrate density and conductivity were measured and correlated to glucose levels. In vitro studies confirmed the ability to predict glucose from density and conductivity measurements, in varying concentrations of glucose and saline. In plasma filtrate, the conductivity and density measurements of ultrafiltrate allowed estimation of glucose in some patients with diabetes but not others. The correlation coefficient for the combined patient data was 0.45 which was significant but only explained 20% of the variability in the glucose levels. Individually, the correlation was significant in only two of the seven patients with correlation coefficients of 0.79 and 0.88. The reasons for lack of correlation are not clear, and cannot be explained by generation of idiogenic osmoles, effects of alcohol dehydrogenase, water intake, etc. This combination of physical methods for glucose measurement is not a feasible approach to measuring glucose in plasma filtrate.

  3. Methazolamide Is a New Hepatic Insulin Sensitizer That Lowers Blood Glucose In Vivo

    Science.gov (United States)

    Konstantopoulos, Nicky; Molero, Juan C.; McGee, Sean L.; Spolding, Briana; Connor, Tim; de Vries, Melissa; Wanyonyi, Stephen; Fahey, Richard; Morrison, Shona; Swinton, Courtney; Jones, Sharon; Cooper, Adrian; Garcia-Guerra, Lucia; Foletta, Victoria C.; Krippner, Guy; Andrikopoulos, Sofianos; Walder, Ken R.

    2012-01-01

    We previously used Gene Expression Signature technology to identify methazolamide (MTZ) and related compounds with insulin sensitizing activity in vitro. The effects of these compounds were investigated in diabetic db/db mice, insulin-resistant diet-induced obese (DIO) mice, and rats with streptozotocin (STZ)-induced diabetes. MTZ reduced fasting blood glucose and HbA1c levels in db/db mice, improved glucose tolerance in DIO mice, and enhanced the glucose-lowering effects of exogenous insulin administration in rats with STZ-induced diabetes. Hyperinsulinemic-euglycemic clamps in DIO mice revealed that MTZ increased glucose infusion rate and suppressed endogenous glucose production. Whole-body or cellular oxygen consumption rate was not altered, suggesting MTZ may inhibit glucose production by different mechanism(s) to metformin. In support of this, MTZ enhanced the glucose-lowering effects of metformin in db/db mice. MTZ is known to be a carbonic anhydrase inhibitor (CAI); however, CAIs acetazolamide, ethoxyzolamide, dichlorphenamide, chlorthalidone, and furosemide were not effective in vivo. Our results demonstrate that MTZ acts as an insulin sensitizer that suppresses hepatic glucose production in vivo. The antidiabetic effect of MTZ does not appear to be a function of its known activity as a CAI. The additive glucose-lowering effect of MTZ together with metformin highlights the potential utility for the management of type 2 diabetes. PMID:22586591

  4. Beta-carotene blood test

    Science.gov (United States)

    Carotene test ... anything for up to 8 hours before the test. You may also be asked not to eat ... vitamin A (carotene) for 48 hours before the test. Your provider may also tell you to temporarily ...

  5. Influence of peritoneal transfer status on fasting blood glucose in non-diabetic nephropathy patients on continuous ambulatory peritoneal dialysis

    Institute of Scientific and Technical Information of China (English)

    YU Xu-fang; ZHOU Yun-fei; FENG Ling; ZHANG Dong-liang; LIU Wen-hu

    2009-01-01

    Background Extra glucose load in peritoneal dialysis is an important cause of newly-occurred diabetic mellitus, which initiates insulin treatment in some of the dialytic patients.The purpose of this study was to discuss the influence of the peritoneal transfer status on fasting blood glucose in non-diabetic nephropathy patients who are on continuous ambulatory peritoneal dialysis (CAPD).Methods One hundred and forty-five patients with total KT/V per week over 2.0 were recruited, including 60 males and 85 females. Fasting blood glucose (FBG), creatinine, blood urea nitrogen (BUN), blood albumin, blood lipid profile and blood C-reactive protein (CRP) were analyzed at the beginning of the peritoneal dialysis and after 12 months. A peritoneal equilibration test (PET) was carried out at the 3rd month of CAPD, and meantime residual renal function, peritoneal solute clearance rate, ultrafiltration volume and urine volume were also evaluated.Results Twenty-one cases were identified as a low transfer group (L), 32 cases as a low average transfer group (LA), 58 cases as a high average transfer group (HA) and 34 cases as a high transfer group (H). At the end of the 12th month, 83 cases had elevated FBG Through stepwise multiple regression analysis we found the FBG level in these patients was positively related to glucose load and CRP, and negatively related to glucose absorption in the peritoneum (D/D_0) and blood albumin (P<0.05). Kaplan-Meier analysis during a 48-month follow-up found the morbidity of hyperglycemia to be 17/34 cases (50.1%) in the high transfer group, 20/58 cases (34.5%) in the high average transfer group, 11/32 cases (34.3%) in the low average transfer group, and 1/21 cases (5.4%) in the low transfer group.Conclusions Patients with high peritoneal transfer capacity might have the highest morbidity from hyperglycemia among patients with these four different peritoneal transfer status. Glucose load, baseline CRP and FBG level before peritoneal dialysis, and

  6. Physical Activity, Blood Glucose and C-Peptide in Healthy School-Children, a Longitudinal Study

    OpenAIRE

    Huus, Karina; Åkerman, Linda; Raustorp, Anders; Ludvigsson, Johnny

    2016-01-01

    Aim To further elucidate the relationship between physical activity and several risk factors for development of diabetes (glucose, C-peptide and obesity) over time. Methods A prospective longitudinal study where physical activity was measured on 199 children from Kalmar and Linkoping at age 8, and the same 107 children from Linkoping again at age 12. Anthropometric data was collected and blood was analyzed for C-peptide and f-glucose. The children in the study were representative for the gene...

  7. The Association between Concentrations of Green Tea and Blood Glucose Levels

    OpenAIRE

    Maruyama, Koutatsu; ISO, Hiroyasu; Sasaki, Satoshi; Fukino, Yoko

    2008-01-01

    Our objective was to examine whether habitual green tea consumption is associated with blood glucose levels and other biomarkers of glucose metabolism. We conducted a cross-sectional study of 35 male volunteers, 23–63 years old and residing in Shizuoka Prefecture in Japan. Biochemical data were measured and we conducted a questionnaire survey on health, lifestyle, and nutrition, as well as frequency of consumption and concentrations (1%, 2%, and 3%) of green tea. Men who consumed a 3% concent...

  8. Profile of blood glucose and ultrastucture of beta cells pancreatic islet in alloxan compound induced rats

    OpenAIRE

    I Nyoman Suarsana; Priosoeryanto, B P; M. Bintang; T. Wresdiyati

    2010-01-01

    Diabetes is marked by elevated levels of blood glucose, and progressive changes of the structure of pancreatic islet histopathology. The objective of this research was to analyse the glucose level and histophatological feature in pancreatic islet in alloxan compound induced rats. A total of ten male Spraque Dawley rats of 2 months old were used in this study. The rats were divided into two groups: (1) negative control group (K-), and (2) positif induced alloxan group (diabetic group =DM). The...

  9. Relationship of endothelial nitric oxide synthase gene polymorphism with blood pressure,lipid profile and blood glucose level

    Institute of Scientific and Technical Information of China (English)

    2008-01-01

    To study the relationship of the polymorphism of endothelial nitric oxide synthase(eNOS)gene and blood pressure,lipid profiles and blood glucose level.By using PCR-RFLP,the eNOS Glu298Asp gene polymorphism was detected in 184 patients with essential hypertension and 196 matched healthy individuals with normal blood pressure.Taking into account eNOS Glu298Asp polymorphisms,the relationship of blood pressure with triglycerides(TG),total cholesterol(TC),high density lipoprotein(HDL),low density lipoprotein(LDL)and blood glucose level was analyzed.The distribution of eNOS Glu298Asp polymorphism had no significant difference between different blood pressure groups and gender groups,but there was a significant difference between different age groups,diastolic blood pressure groups or BMI groups(P<0.05).Asp/Asp genotype significantly increased the risk of hypertension in individuals with serum TC above 5.4 mmol/L(P=0.03,OR=2.65).eNOSGlu298Asp polymorphism and serum lipid could synergistically modulate the blood pressure,eNOS Asp/Asp genotype could significantly increase the risk of hypertension in individuals with serum TC over 5.4 mmol/L,eNOS Glu298Asp in combination with serum TC could be used to predict the risk of hypertension.

  10. Related research of blood glucose, blood lipid and serum cystatin C and lower-extremity arterial disease in type 2 diabetic mellitus

    Institute of Scientific and Technical Information of China (English)

    Juan Zeng; Jie Ou; Yun-Mei He; Chun-Yu Cai

    2016-01-01

    Objective:To explore the relationship between levels of blood glucose, blood lipid and serum cystatin C and lower-extremity arterial disease in type 2 diabetic mellitus so as to provide the basis for the prevention and treatment of the disease.Methods:A total of 240 cases of patients with type 2 diabetic mellitus receiving physical examinations in our hospital from March 2014 to March 2015 were selected and divided into three groups. The control group was consisted of type 2 diabetes patients without lower-extremity arterial disease, the observation group 1 included type 2 diabetes patients with mild or moderate lower-extremity arterial disease, and the observation group 2 was formed by type 2 diabetes patients with severe lower-extremity arterial disease. Each group contained 80 cases. Then, the heights, weights, waist and hip circumferences of patients in the three groups were determined and the body mass index (BMI) and waist to hip ratio (WHR) were calculated; the fasting blood glucose (FBG), fasting insulin (FINS), insulin resistance index (HOMA-IR), 2 h postprandial blood glucose (2 h PG) and glycosylated hemoglobin (HBA1c) in two groups were detected; and the levels of serum total cholesterol(TC), triglyceride (TG), low density lipoprotein cholesterol (LDL-C), high density lipoprotein cholesterol (HDL-C), apolipoprotein A1 (apoA1), apolipoprotein B (apoB) and cystatin C (CysC) in two groups were also tested.Results:Compared with the control group, the WHR, FBG, HOMA-IR, 2 h PG, HBA1c, LDL-C, apoB and CysC all increased significantly, and the differences were statistically significant. Besides, there were statistically significances existing between the observation groups 1 and 2. What’s more, the serum levels of TC, HDL-C, TG and apoA1 in the observation groups were not significantly different from those of the control group.Conclusions: There is a close relationship between blood glucose, blood lipid, serum cystatin C level and lower-extremity arterial

  11. Cerebral blood flow, oxygen and glucose metabolism with PET in progressive supranuclear palsy

    Energy Technology Data Exchange (ETDEWEB)

    Otsuka, Makoto; Ichiya, Yuici; Kuwabara, Yasuo (Kyushu Univ., Fukuoka (Japan). Faculty of Medicine) (and others)

    1989-11-01

    Cerebral blood flow, cerebral oxygen metabolic rate and cerebral glucose metabolic rate were measured with positron emission tomography (PET) in four patients with progressive supranuclear palsy (PSP). Decreased blood flow and hypometabolism of oxygen and glucose were found in both subcortical and cortical regions, particularly in the striatum including the head of the caudate nucleus and the frontal cortex. The coupling between blood flow and metabolism was preserved even in the regions which showed decreased blood flow and hypometabolism. These findings indicated the hypofunction, as revealed by decreased blood flow and hypometablolism on PET, both in the striatum and the frontal cortex, and which may underlie the pathophysiological mechanism of motor and mental disturbance in PSP. (author).

  12. Cerebral blood flow, oxygen and glucose metabolism with PET in progressive supranuclear palsy

    International Nuclear Information System (INIS)

    Cerebral blood flow, cerebral oxygen metabolic rate and cerebral glucose metabolic rate were measured with positron emission tomography (PET) in four patients with progressive supranuclear palsy (PSP). Decreased blood flow and hypometabolism of oxygen and glucose were found in both subcortical and cortical regions, particularly in the striatum including the head of the caudate nucleus and the frontal cortex. The coupling between blood flow and metabolism was preserved even in the regions which showed decreased blood flow and hypometabolism. These findings indicated the hypofunction, as revealed by decreased blood flow and hypometablolism on PET, both in the striatum and the frontal cortex, and which may underlie the pathophysiological mechanism of motor and mental disturbance in PSP. (author)

  13. Glucose challenge test (50-g GCT) in detection of glucose metabolism disorders in peritoneal dialysis patients: preliminary study

    OpenAIRE

    Madziarska, Katarzyna; Zmonarski, Slawomir; Penar, Jozef; Krajewska, Magdalena; Mazanowska, Oktawia; Augustyniak-Bartosik, Hanna; Gołebiowski, Tomasz; Klak, Renata; Weyde, Waclaw; Klinger, Marian

    2014-01-01

    Background The aim was to evaluate the clinical utility of the oral glucose tolerance screening test (50-g GCT—glucose challenge test) for the detection of glucose metabolism disorders (GMD) in peritoneal dialysis (PD) patients with normal fasting glucose levels. Methods The 50-g GCT was performed in 20 prevalent patients without history of diabetes before PD treatment onset, who had been on dialysis for a median time of 15.34 months. In addition, other indicators of glucose metabolism were m...

  14. Diabetes mellitus, fasting blood glucose concentration, and risk of vascular disease

    DEFF Research Database (Denmark)

    Sarwar, N; Gao, P; Seshasai, S R Kondapally;

    2010-01-01

    BACKGROUND: Uncertainties persist about the magnitude of associations of diabetes mellitus and fasting glucose concentration with risk of coronary heart disease and major stroke subtypes. We aimed to quantify these associations for a wide range of circumstances. METHODS: We undertook a meta...... markers. HRs for coronary heart disease were higher in women than in men, at 40-59 years than at 70 years and older, and with fatal than with non-fatal disease. At an adult population-wide prevalence of 10%, diabetes was estimated to account for 11% (10-12%) of vascular deaths. Fasting blood glucose......-analysis of individual records of diabetes, fasting blood glucose concentration, and other risk factors in people without initial vascular disease from studies in the Emerging Risk Factors Collaboration. We combined within-study regressions that were adjusted for age, sex, smoking, systolic blood pressure...

  15. Specificity of noninvasive blood glucose sensing using optical coherence tomography technique: a pilot study

    International Nuclear Information System (INIS)

    Noninvasive monitoring of blood glucose concentration in diabetic patients would significantly reduce complications and mortality associated with this disease. In this paper, we experimentally and theoretically studied specificity of noninvasive blood glucose monitoring with the optical coherence tomography (OCT) technique. OCT images and signals were obtained from skin of Yucatan micropigs and New Zealand rabbits. Obtained results demonstrate that: (1) several body osmolytes may change the refractive index mismatch between the interstitial fluid (ISF) and scattering centres in tissue, however the effect of the glucose is approximately one to two orders of magnitude higher; (2) an increase of the ISF glucose concentration in the physiological range (3-30 mM) may decrease the scattering coefficient by 0.22% mM-1 due to cell volume change; (3) stability of the OCT signal slope is dependent on tissue heterogeneity and motion artefacts; and (4) moderate skin temperature fluctuations (±1 deg. C) do not decrease accuracy and specificity of the OCT-based glucose sensor, however substantial skin heating or cooling (several deg. C) significantly change the OCT signal slope. These results suggest that the OCT technique may provide blood glucose concentration monitoring with sufficient specificity under normal physiological conditions

  16. Low Red Blood Cell Vitamin C Concentrations Induce Red Blood Cell Fragility: A Link to Diabetes Via Glucose, Glucose Transporters, and Dehydroascorbic Acid

    Directory of Open Access Journals (Sweden)

    Hongbin Tu

    2015-11-01

    Full Text Available Strategies to prevent diabetic microvascular angiopathy focus on the vascular endothelium. Because red blood cells (RBCs are less deformable in diabetes, we explored an original concept linking decreased RBC deformability to RBC ascorbate and hyperglycemia. We characterized ascorbate concentrations from human and mouse RBCs and plasma, and showed an inverse relationship between RBC ascorbate concentrations and deformability, measured by osmotic fragility. RBCs from ascorbate deficient mice were osmotically sensitive, appeared as spherocytes, and had decreased β-spectrin. These aberrancies reversed with ascorbate repletion in vivo. Under physiologic conditions, only ascorbate's oxidation product dehydroascorbic acid (DHA, a substrate for facilitated glucose transporters, was transported into mouse and human RBCs, with immediate intracellular reduction to ascorbate. In vitro, glucose inhibited entry of physiologic concentrations of dehydroascorbic acid into mouse and human RBCs. In vivo, plasma glucose concentrations in normal and diabetic mice and humans were inversely related to respective RBC ascorbate concentrations, as was osmotic fragility. Human RBC β-spectrin declined as diabetes worsened. Taken together, hyperglycemia in diabetes produced lower RBC ascorbate with increased RBC rigidity, a candidate to drive microvascular angiopathy. Because glucose transporter expression, DHA transport, and its inhibition by glucose differed for mouse versus human RBCs, human experimentation is indicated.

  17. Gcg-XTEN: an improved glucagon capable of preventing hypoglycemia without increasing baseline blood glucose.

    Directory of Open Access Journals (Sweden)

    Nathan C Geething

    Full Text Available OBJECTIVE: While the majority of current diabetes treatments focus on reducing blood glucose levels, hypoglycemia represents a significant risk associated with insulin treatment. Glucagon plays a major regulatory role in controlling hypoglycemia in vivo, but its short half-life and hyperglycemic effects prevent its therapeutic use for non-acute applications. The goal of this study was to identify a modified form of glucagon suitable for prophylactic treatment of hypoglycemia without increasing baseline blood glucose levels. METHODOLOGY/PRINCIPAL FINDINGS: Through application of the XTEN technology, we report the construction of a glucagon fusion protein with an extended exposure profile (Gcg-XTEN. The in vivo half-life of the construct was tuned to support nightly dosing through design and testing in cynomolgus monkeys. Efficacy of the construct was assessed in beagle dogs using an insulin challenge to induce hypoglycemia. Dose ranging of Gcg-XTEN in fasted beagle dogs demonstrated that the compound was biologically active with a pharmacodynamic profile consistent with the designed half-life. Prophylactic administration of 0.6 nmol/kg Gcg-XTEN to dogs conferred resistance to a hypoglycemic challenge at 6 hours post-dose without affecting baseline blood glucose levels. Consistent with the designed pharmacokinetic profile, hypoglycemia resistance was not observed at 12 hours post-dose. Importantly, the solubility and stability of the glucagon peptide were also significantly improved by fusion to XTEN. CONCLUSIONS/SIGNIFICANCE: The data show that Gcg-XTEN is effective in preventing hypoglycemia without the associated hyperglycemia expected for unmodified glucagon. While the plasma clearance of this Gcg-XTEN has been optimized for overnight dosing, specifically for the treatment of nocturnal hypoglycemia, constructs with significantly longer exposure profiles are feasible. Such constructs may have multiple applications such as allowing for more

  18. Magnesium enhances exercise performance via increasing glucose availability in the blood, muscle, and brain during exercise.

    Directory of Open Access Journals (Sweden)

    Hsuan-Ying Chen

    Full Text Available Glucose mobilization and utilization in the periphery and central nervous system are important during exercise and are responsible for exercise efficacy. Magnesium (Mg is involved in energy production and plays a role in exercise performance. This study aimed to explore the effects of Mg on the dynamic changes in glucose and lactate levels in the muscle, blood and brain of exercising rats using a combination of auto-blood sampling and microdialysis. Sprague-Dawley rats were pretreated with saline or magnesium sulfate (MgSO4, 90 mg/kg, i.p. 30 min before treadmill exercise (20 m/min for 60 min. Our results indicated that the muscle, blood, and brain glucose levels immediately increased during exercise, and then gradually decreased to near basal levels in the recovery periods of both groups. These glucose levels were significantly enhanced to approximately two-fold (P<0.05 in the Mg group. Lactate levels in the muscle, blood, and brain rapidly and significantly increased in both groups during exercise, and brain lactate levels in the Mg group further elevated (P<0.05 than those in the control group during exercise. Lactate levels significantly decreased after exercise in both groups. In conclusion, Mg enhanced glucose availability in the peripheral and central systems, and increased lactate clearance in the muscle during exercise.

  19. Effect of Ramadan fasting and triangular exercise progressive on the vigilance, mood and blood glucose in trained athletes

    Directory of Open Access Journals (Sweden)

    Lotfi Said

    2015-09-01

    Full Text Available Purpose: This study has for objective the assessment of the vigilance, mood states variations and the blood glucose levels, during a triangular effort progressive in trained athletes during Ramadan fasting (RF. Methods. Ten trained male athletes aged 21.8 ± 1.1 years are evaluated before (B.RF, during (1st, 2nd and 3th week and after Ramadan fasting, in the blood-glucose, vigilance, and mood states at rest and after (A. Ex. a triangular exercise test (TUB II.Results. Comparing to the reference period (B.RF, the RF induces a decrease in the maximal aerobic power (TUB II approximately 2-Cleanup Messy Code 5% and a hypoglycaemia. The objective vigilance is doubly influenced by the RF (F= 14.58, p

  20. The juice of fresh leaves of Catharanthus roseus Linn. reduces blood glucose in normal and alloxan diabetic rabbits

    Directory of Open Access Journals (Sweden)

    Lodagala Srinivas D

    2003-09-01

    Full Text Available Abstract Background The leaf juice or water decoction of Catharanthus roseus L. (Apocyanaceae is used as a folk medicine for the treatment of diabetes all over the world. In the present investigation, the leaf juice of C. roseus has been evaluated for its hypoglycemic activity in normal and alloxan-induced diabetic rabbits. Methods The blood glucose lowering activity of the leaf juice was studied in normal and alloxan-induced (100 mg/kg, i.v. diabetic rabbits, after oral administration at doses of 0.5, 0.75 and 1.0 ml/kg body weight. Blood samples were collected from the marginal ear vein before and also at 4, 6, 8, 10, 12, 16, 18, 20 & 24 h after drug administration and blood glucose was analyzed by Nelson-Somogyi's method using a visible spectrophotometer. The data was compared statistically by using Student's t-test. Results The leaf juice of C. roseus produced dose-dependent reduction in blood glucose of both normal and diabetic rabbits and comparable with that of the standard drug, glibenclamide. The results indicate a prolonged action in reduction of blood glucose by C. roseus and the mode of action of the active compound(s of C. roseus is probably mediated through enhance secretion of insulin from the β-cells of Langerhans or through extrapancreatic mechanism. Conclusions The present study clearly indicated a significant antidiabetic activity with the leaf juice of Catharanthus roseus and supports the traditional usage of the fresh leaves by Ayurvedic physicians for the control of diabetes.

  1. The juice of fresh leaves of Catharanthus roseus Linn. reduces blood glucose in normal and alloxan diabetic rabbits

    Science.gov (United States)

    Nammi, Srinivas; Boini, Murthy K; Lodagala, Srinivas D; Behara, Ravindra Babu S

    2003-01-01

    Background The leaf juice or water decoction of Catharanthus roseus L. (Apocyanaceae) is used as a folk medicine for the treatment of diabetes all over the world. In the present investigation, the leaf juice of C. roseus has been evaluated for its hypoglycemic activity in normal and alloxan-induced diabetic rabbits. Methods The blood glucose lowering activity of the leaf juice was studied in normal and alloxan-induced (100 mg/kg, i.v.) diabetic rabbits, after oral administration at doses of 0.5, 0.75 and 1.0 ml/kg body weight. Blood samples were collected from the marginal ear vein before and also at 4, 6, 8, 10, 12, 16, 18, 20 & 24 h after drug administration and blood glucose was analyzed by Nelson-Somogyi's method using a visible spectrophotometer. The data was compared statistically by using Student's t-test. Results The leaf juice of C. roseus produced dose-dependent reduction in blood glucose of both normal and diabetic rabbits and comparable with that of the standard drug, glibenclamide. The results indicate a prolonged action in reduction of blood glucose by C. roseus and the mode of action of the active compound(s) of C. roseus is probably mediated through enhance secretion of insulin from the β-cells of Langerhans or through extrapancreatic mechanism. Conclusions The present study clearly indicated a significant antidiabetic activity with the leaf juice of Catharanthus roseus and supports the traditional usage of the fresh leaves by Ayurvedic physicians for the control of diabetes. PMID:12950994

  2. Lanthanides' enhancing absorption of insulin and reduction of blood glucose of rat by pulmonary administration

    Institute of Scientific and Technical Information of China (English)

    2000-01-01

    To explore the possibility of lanthanides as the enhancer of insulin absorption, the promoting effects of lanthanide ions on the absorption of intrapulmonary delivered insulin and reduction of blood glucose were investigated by means of two approaches, preadministration and coadministration of lanthanide ions with insulin. The results indicate that, compared with the results of those given insulin only, lanthanide ions can effectively enhance the level of insulin and the reduction of glucose level in blood. These effects are dependent on lanthanide species and their concentrations. The mechanism was discussed.

  3. Effect of VCO to leucocyte differential count, glucose levels and blood creatinine of hyperglycemic and ovalbumin sensitized Mus musculus Balb/c

    Directory of Open Access Journals (Sweden)

    RUBEN DHARMAWAN

    2009-03-01

    Full Text Available Abstract. Handajani NS, Dharmawan R. 2009. Effect of VCO to leucocyte differential count, glucose levels and blood creatinine of hyperglycemic and ovalbumin sensitized Mus musculus Balb/c. Nusantara Bioscience 1: 1-8. Chemical medicines and insulin can decrease glucose blood level on hyperglycemic patients with macro vascular side effect. Diabetes and allergy incidences are influenced by quality and quantity of leucocytes. Lauric acid within VCO reports decreased glucose blood level of diabetes and some allergy incidents. The purpose of the study is to know the effect of VCO on glucose blood level, differential leucocytes count and creatinine blood level on hyperglycemic and normoglicemic ovalbumin sensitized mice. Forty five (45 male (mice of Mus musculus Balb/c with average weight of 35 g are divided into 9 groups with 5 repetitions, those are 4 non alloxan groups and 5 alloxan induced hyperglycemic groups. On 22nd day to 36th day they are sensitize to ovalbumin as allergen. Blood sample was obtained by orbital vena using heparin as anti coagulant in order measuring glucose blood level by GOD method to 6 times, on 1st, 4th, 18th, 22nd, 32nd and 37th days, then are tested by ANOVA followed by DMRT 0.05. On 37th day, differential leucocytes are determined, blood level are counted, and then compared to normal value. The result of this study were that within differential leucocytes count of hyperglycemic mice, neutrophile percentage were much lower than the normal value (3.22%, and lymphocyte percentage were much higher than the normal value (94.54%. Consumed 0.003 mL/35 g VCO more 18 days decreased glucose blood level on hyperglycemic mice, decreased basophile percentage of ovalbumin sensitized mice, normalized neutrophile percentage no increased creatinine blood level.

  4. Influence of the blood glucose level on the development of retinopathy of prematurity in extremely premature children

    Directory of Open Access Journals (Sweden)

    Galina V. Nicolaeva

    2015-08-01

    Full Text Available ABSTRACTPurpose:To investigate the influence of the blood glucose level on the development of retinopathy of prematurity (ROP in extremely premature infants.Methods:Sixty-four premature infants with a gestational age of less than 30 weeks and a birth weight of less than 1500 g were included in the study. Children without ROP were allocated to Group 1 (n=14, gestational age 28.6 ± 1.4 weeks, birth weight 1162 ± 322 g, and children with spontaneous regression of ROP were allocated to Group 2 (n=32, gestational age 26.5 ± 1.2 weeks, birth weight 905 ± 224 g. Children with progressive ROP who underwent laser treatment were included in Group 3 (n=18, gestational age 25.4 ± 0.7 weeks, birth weight 763 ± 138 g. The glucose level in the capillary blood of the premature infants was monitored daily during the first 3 weeks of life. A complete ophthalmological screening was performed from the age of 1 month. The nonparametric signed-rank Wilcoxon-Mann-Whitney test was used for statistical analysis.Results:The mean blood glucose level was 7.43 ± 2.6 mmol/L in Group 1, 7.8 ± 2.7 mmol/L in Group 2, and 6.7 ± 2.6 mmol/L in Group 3. There were no significant differences in the blood glucose levels between children with and without ROP, and also between children with spontaneously regressing ROP and progressive ROP (p>0.05. Additionally, there were no significant differences in the blood glucose levels measured at the first, second, and third weeks of life (p>0.05.Conclusion:The blood glucose level is not related to the development of ROP nor with its progression or regression. The glycemic level cannot be considered as a risk factor for ROP, but reflects the severity of newborns’ somatic condition and morphofunctional immaturity.

  5. The food and drug administration is now preparing to establish tighter performance requirements for blood glucose monitors.

    Science.gov (United States)

    Klonoff, David C

    2010-05-01

    On March 16 and 17, 2010, the Food and Drug Administration (FDA) presented a public meeting about blood glucose monitoring at the Gaithersberg Hilton Hotel. The meeting was intended to present expert opinions and solicit input from the public about whether to develop new regulatory policies for blood glucose monitors. The meeting was divided into three sections: (1) Clinical Accuracy Requirements for Blood Glucose Monitors, (2) Interferences and Limitations of Blood Glucose Monitors, and (3) Tight Glycemic Control. Many officials from the Center for Devices and Radiologic Health and the Office of In Vitro Diagnostic Devices, which are the parts of FDA that regulate approval of blood glucose monitors, either spoke on the agenda or attended in the audience. Approximately 300 people attended; they were mostly clinicians (such as adult endocrinologists, pediatric endocrinologists, internists, clinical chemists, intensivists, surgeons, nurses, and diabetes educators) or industry officials from companies involved in glucose monitoring, pharmaceutical products, data analysis, or regulatory consulting. PMID:20513313

  6. Clinical utility and accuracy of a blood glucose meter for the detection of neonatal hypoglycemia

    International Nuclear Information System (INIS)

    Objective: To determine the accuracy and reliability of a glucometer in comparison to hexokinase method in detecting neonatal hypoglycemia. Subjects and Methods: All neonates presenting with known risk factors or suggestive clinical features were screened for hypoglycemia by using capillary blood on Accutrend alpha glucometer. Simultaneously the venous blood glucose values were done on Hitachi 902 autoanalyser by hexokinase method. A level of 40 mg/dl or less was taken as neonatal hypoglycemia. Results: A total of 292-paired samples were taken from 223 neonates. Hypoglycemia was detected in 112 samples (38.4%). Correlation of glucometer values with laboratory values of blood glucose levels was excellent throughout the range with coefficient of correlation (r) of 0.976 (p-value < 0.001). For blood glucose values equal or less than 40 mg/dl, r was 0.547 (p-value < 0.001). The instrument used showed a sensitivity of 98% and specificity of 93% to detect neonatal hypoglycemia (equal or less than 40 mg/dl) with a positive predictive value of 88% and negative predictive value 99%. Conclusion: The blood glucose reflectance meter can be a useful and accurate instrument for screening and detecting neonatal hypoglycemia in symptomatic babies under stress. All low values by glucometer should be promptly analyzed and confirmed by chemical laboratory. (author)

  7. PSECMAC intelligent insulin schedule for diabetic blood glucose management under nonmeal announcement.

    Science.gov (United States)

    Teddy, S D; Quek, C; Lai, E M-K; Cinar, A

    2010-03-01

    Therapeutically, the closed-loop blood glucose-insulin regulation paradigm via a controllable insulin pump offers a potential solution to the management of diabetes. However, the development of such a closed-loop regulatory system to date has been hampered by two main issues: 1) the limited knowledge on the complex human physiological process of glucose-insulin metabolism that prevents a precise modeling of the biological blood glucose control loop; and 2) the vast metabolic biodiversity of the diabetic population due to varying exogneous and endogenous disturbances such as food intake, exercise, stress, and hormonal factors, etc. In addition, current attempts of closed-loop glucose regulatory techniques generally require some form of prior meal announcement and this constitutes a severe limitation to the applicability of such systems. In this paper, we present a novel intelligent insulin schedule based on the pseudo self-evolving cerebellar model articulation controller (PSECMAC) associative learning memory model that emulates the healthy human insulin response to food ingestion. The proposed PSECMAC intelligent insulin schedule requires no prior meal announcement and delivers the necessary insulin dosage based only on the observed blood glucose fluctuations. Using a simulated healthy subject, the proposed PSECMAC insulin schedule is demonstrated to be able to accurately capture the complex human glucose-insulin dynamics and robustly addresses the intraperson metabolic variability. Subsequently, the PSECMAC intelligent insulin schedule is employed on a group of type-1 diabetic patients to regulate their impaired blood glucose levels. Preliminary simulation results are highly encouraging. The work reported in this paper represents a major paradigm shift in the management of diabetes where patient compliance is poor and the need for prior meal announcement under current treatment regimes poses a significant challenge to an active lifestyle.

  8. Blood glucose levels and cortical thinning in cognitively normal, middle-aged adults.

    Science.gov (United States)

    Wennberg, Alexandra M V; Spira, Adam P; Pettigrew, Corinne; Soldan, Anja; Zipunnikov, Vadim; Rebok, George W; Roses, Allen D; Lutz, Michael W; Miller, Michael M; Thambisetty, Madhav; Albert, Marilyn S

    2016-06-15

    Type II diabetes mellitus (DM) increases risk for cognitive decline and is associated with brain atrophy in older demented and non-demented individuals. We investigated (1) the cross-sectional association between fasting blood glucose level and cortical thickness in a sample of largely middle-aged, cognitively normal adults, and (2) whether these associations were modified by genes associated with both lipid processing and dementia. To explore possible modifications by genetic status, we investigated the interaction between blood glucose levels and the apolipoprotein E (APOE) ε4 allele and the translocase of the outer mitochondrial membrane (TOMM) 40 '523 genotype on cortical thickness. Cortical thickness measures were based on mean thickness in a subset of a priori-selected brain regions hypothesized to be vulnerable to atrophy in Alzheimer's disease (AD) (i.e., 'AD vulnerable regions'). Participants included 233 cognitively normal subjects in the BIOCARD study who had a measure of fasting blood glucose and cortical thickness measures, quantified by magnetic resonance imaging (MRI) scans. After adjustment for age, sex, race, education, depression, and medical conditions, higher blood glucose was associated with thinner parahippocampal gyri (B=-0.002; 95% CI -0.004, -0.0004) and temporal pole (B=-0.002; 95% CI -0.004, -0.0001), as well as reduced average thickness over AD vulnerable regions (B=-0.001; 95% CI -0.002, -0.0001). There was no evidence for greater cortical thinning in ε4 carriers of the APOE gene or in APOE ε3/3 individuals carrying the TOMM40 VL/VL genotypes. When individuals with glucose levels in the diabetic range (≥126mg/dL), were excluded from the analysis, the associations between glucose levels and cortical thickness were no longer significant. These findings suggest that glucose levels in the diabetic range are associated with reduced cortical thickness in AD vulnerable regions as early as middle age. PMID:27206882

  9. 血糖在3种真空采血管中放置不同时间的稳定性研究%Study on the stability of blood glucose after different storage time in three kinds of vacuum test tube

    Institute of Scientific and Technical Information of China (English)

    莫巧璇; 梁敏华; 钟幸容; 谭顺莲

    2014-01-01

    目的:探讨3种真空采血管中的血液标本放置不同时间对血糖检测结果的影响。方法收集佛山市中医院2013年11~12月门诊患者中同时要抽肝素抗凝血、氟化钠/EDTA-K2抗凝血、分离胶促凝血的静脉血液标本,立即离心(3000 r/min,5 min),分别在室温(22℃)下放置0、1、2、4、6 h,4℃冰箱放置24、48、72 h 后检测血糖浓度,观察血糖浓度在3种不同真空采血管中及在放置不同时间内的稳定性。结果氟化钠/ EDTA-K2抗凝血浆的0 h 血糖值最低,分离胶促凝剂促凝血清血糖值浓度最高,三者差异有统计学意义(P <0.05)。肝素钠抗凝真空采血管、氟化钠/ EDTA-K2抗凝真空采血管、分离胶促凝剂真空采血管中的血液标本的血糖分别可稳定4、24、48 h (P >0.05),而分别在各自稳定时间之后,血糖浓度各管均有所下降,差异有统计学意义(P <0.05)。结论鉴于实验统计得出该三种不同的真空采血管对血糖的稳定时间的不同,同时结合三种管的使用特点,建议肝素钠抗凝血用于需要紧急检测的血糖或含血糖组合项目的生化标本检测,同时抽取肝素钠和氟化钠/ EDTA-K2两管抗凝血液用于住院部患者上述项目的生化标本检测,而分离胶促凝血标本用于门诊患者上述项目的生化标本检测。%Objective To investigate the effect of three kinds of vacuum test tube afeter different storage time on blood glucose test results.Methods Collected heparin anticoagulant sodium fluoride/EDTA- K2 anticoagulant blood,separating gel coagulation of blood vein blood samples in the traditional chinese medicine hospital of Foshan, centrifuged immediately(3000r,5min),then stored respectively at room temperature(22 ℃)for 0,1,2,4,6h,at 4 ℃refrigerator placed 24,48,72h,detected the stability of blood glucose concentrations at different time in 3 different vacuum test tube

  10. Toothbrushing, Blood Glucose and HbA1c: Findings from a Random Survey in Chinese Population.

    Science.gov (United States)

    Su, Lingyu; Liu, Wenzhao; Xie, Bingwu; Dou, Lei; Sun, Jun; Wan, Wenjuan; Fu, Xiaoming; Li, Guangyue; Huang, Jiao; Xu, Ling

    2016-01-01

    Both diabetes and periodontal disease are prevalent in China. Poor oral hygiene practice is the major cause of periodontal disease. An association between oral hygiene practice and blood glucose level was reported in individuals with diabetes, but not in the general population. We examined the association in a population-based random survey recruiting 2,105 adults without previously diagnosed diabetes in Chongqing city, China. Plasma glucose and hemoglobin A1c (HbA1c) were measured, and a 2-hour oral glucose tolerance test was conducted for each respondent. Self-reported toothbrushing frequency was used as a proxy for oral hygiene practice. In a linear model controlling for potential confounders (demographic characteristics, socio-economic status, lifestyle risk factors, BMI, dental visit frequency, etc.), urban residents who barely brushed their teeth had an increase of 0.50 (95% CI: 0.10-0.90) mmol/L in fasting plasma glucose, and an increase of 0.26% (0.04-0.47%) in HbA1c, relative to those brushing ≥twice daily; for rural residents, the effects were 0.26 (0.05-0.48) mmol/L in fasting plasma glucose and 0.20% (0.09-0.31%) in HbA1c. Individuals with better oral practice tended to have lower level of blood glucose and HbA1c. Establishing good oral health behavioral habits may be conducive to diabetes prevention and control in the general population. PMID:27385509

  11. Toothbrushing, Blood Glucose and HbA1c: Findings from a Random Survey in Chinese Population

    Science.gov (United States)

    Su, Lingyu; Liu, Wenzhao; Xie, Bingwu; Dou, Lei; Sun, Jun; Wan, Wenjuan; Fu, Xiaoming; Li, Guangyue; Huang, Jiao; Xu, Ling

    2016-01-01

    Both diabetes and periodontal disease are prevalent in China. Poor oral hygiene practice is the major cause of periodontal disease. An association between oral hygiene practice and blood glucose level was reported in individuals with diabetes, but not in the general population. We examined the association in a population-based random survey recruiting 2,105 adults without previously diagnosed diabetes in Chongqing city, China. Plasma glucose and hemoglobin A1c (HbA1c) were measured, and a 2-hour oral glucose tolerance test was conducted for each respondent. Self-reported toothbrushing frequency was used as a proxy for oral hygiene practice. In a linear model controlling for potential confounders (demographic characteristics, socio-economic status, lifestyle risk factors, BMI, dental visit frequency, etc.), urban residents who barely brushed their teeth had an increase of 0.50 (95% CI: 0.10–0.90) mmol/L in fasting plasma glucose, and an increase of 0.26% (0.04–0.47%) in HbA1c, relative to those brushing ≥twice daily; for rural residents, the effects were 0.26 (0.05–0.48) mmol/L in fasting plasma glucose and 0.20% (0.09–0.31%) in HbA1c. Individuals with better oral practice tended to have lower level of blood glucose and HbA1c. Establishing good oral health behavioral habits may be conducive to diabetes prevention and control in the general population. PMID:27385509

  12. Evaluation of first phase insulin secretion by a nateglinide-intravenous glucose insulin release test in newly diagnosed type 2 diabetics

    Institute of Scientific and Technical Information of China (English)

    罗国春

    2006-01-01

    Objective To evaluate the function of the first phase of insulin secretion of pancreatic B cells in newly diagnosed type 2 diabetics using nateglinide-intravenous glucose insulin release test (NG-IVGIRT). Methods NG-IVGIRT and intravenous glucose insulin release test (IVGIRT) were done in 8 patients with newly diagnosed type 2 diabetes mellitus and NG-IVGIRT was done in 8 normal people. Insulin and glucose of blood were deter-

  13. Changes in blood pressure and body weight over ten years in men selected for glucose intolerance.

    OpenAIRE

    Jarrett, R J; Keen, H; Murrells, T

    1987-01-01

    Relative changes in body weight and blood pressure over ten years of observation are reported in men recruited for a trial of therapy in relation to the natural history of glucose intolerance. Half were recommended a diet restricting carbohydrate to 120 g daily (diet group) and half were recommended to 'limit use of table sugar' (no diet). In both groups average weight and blood pressure fell over the 12 to 18 months after treatment allocation, the decline being proportionately greater for bo...

  14. Optimal Control of Blood Glucose: The Diabetic Patient or the Machine?

    OpenAIRE

    Brown, Larry; Edelman, Elazer R.

    2010-01-01

    In this issue of Science Translational Medicine, El-Khatib et al. describe a “closed-loop” bi-hormonal artificial pancreas, designed to avert episodes of low blood sugar in patients with insulin-dependent diabetes. We discuss the benefits and challenges of therapy directed at tight control of blood glucose and ask whether this and similar technological breakthroughs can address as yet unanswered questions in the biology of diabetes.

  15. Melatonin Signaling Controls the Daily Rhythm in Blood Glucose Levels Independent of Peripheral Clocks.

    Directory of Open Access Journals (Sweden)

    Sharon Owino

    Full Text Available Melatonin is rhythmically secreted by both the pineal gland and retina in a circadian fashion, with its peak synthesis occurring during the night. Once synthesized, melatonin exerts its effects by binding to two specific G-protein coupled receptors-melatonin receptor type 1(MT1 and melatonin receptor type 2(MT2. Recent studies suggest the involvement of MT1 and MT2 in the regulation of glucose homeostasis; however the ability of melatonin signaling to impart timing cues on glucose metabolism remains poorly understood. Here we report that the removal of MT1 or MT2 in mice abolishes the daily rhythm in blood glucose levels. Interestingly, removal of melatonin receptors produced small effects on the rhythmic expression patterns of clock genes within skeletal muscle, liver, and adipose tissue. Taken together, our data suggest that the loss of the daily rhythm in blood glucose observed in MT1(-/- and MT2(-/- mice does not occur as a consequence of 'disrupted' clocks within insulin sensitive tissues. Finally our results highlight a diurnal contribution of melatonin receptor signaling in the daily regulation of blood glucose levels.

  16. Lithium modulates the chronic stress-induced effect on blood glucose level of male rats

    Directory of Open Access Journals (Sweden)

    Popović Nataša

    2010-01-01

    Full Text Available In the present study we examined gross changes in the mass of whole adrenal glands and that of the adrenal cortex, as well as the serum corticosterone and glucose level of mature male Wistar rats subjected to three different treatments: animals subjected to chronic restraint-stress, animals injected with lithium (Li and chronically stressed rats treated with Li. Under all three conditions we observed hypertrophy of whole adrenals, as well as the adrenal cortices. Chronic restraint stress, solely or in combination with Li treatment, significantly elevated the corticosterone level, but did not change the blood glucose level. Animals treated only with Li exhibited an elevated serum corticosterone level and blood glucose level. The aim of our study was to investigate the modulation of the chronic stress-induced effect on the blood glucose level by lithium, as a possible mechanism of avoiding the damage caused by chronic stress. Our results showed that lithium is an agent of choice which may help to reduce stress-elevated corticosterone and replenish exhausted glucose storages in an organism.

  17. Early blood glucose profile and neurodevelopmental outcome at two years in neonatal hypoxic-ischaemic encephalopathy

    LENUS (Irish Health Repository)

    Nadeem, Montasser

    2011-02-04

    Abstract Background To examine the blood glucose profile and the relationship between blood glucose levels and neurodevelopmental outcome in term infants with hypoxic-ischaemic encephalopathy. Methods Blood glucose values within 72 hours of birth were collected from 52 term infants with hypoxic-ischaemic encephalopathy. Hypoglycaemia [< 46.8 mg\\/dL (2.6 mmol\\/L)] and hyperglycaemia [> 150 mg\\/dL (8.3 mmol\\/L)] were correlated to neurodevelopmental outcome at 24 months of age. Results Four fifths of the 468 blood samples were in the normoglycaemic range (392\\/468:83.8%). Of the remaining 76 samples, 51.3% were in the hypoglycaemic range and (48.7%) were hyperglycaemic. A quarter of the hypoglycaemic samples (28.2%:11\\/39) and a third of the hyperglycaemic samples (32.4%:12\\/37) were recorded within the first 30 minutes of life. Mean (SD) blood glucose values did not differ between infants with normal and abnormal outcomes [4.89(2.28) mmol\\/L and 5.02(2.35) mmol\\/L, p value = 0.15] respectively. In term infants with hypoxic-ischaemic encephalopathy, early hypoglycaemia (between 0-6 hours of life) was associated with adverse outcome at 24 months of age [OR = 5.8, CI = 1.04-32)]. On multivariate analysis to adjust for grade of HIE this association was not statistically significant. Late hypoglycaemia (6-72 hours of life) was not associated with abnormal outcome [OR = 0.22, CI (0.04-1.14)]. The occurrence of hyperglycaemia was not associated with adverse outcome. Conclusion During the first 72 hours of life, blood glucose profile in infants with hypoxic-ischaemic encephalopathy varies widely despite a management protocol. Early hypoglycaemia (0-6 hours of life) was associated with severe HIE, and thereby; adverse outcome.

  18. Early blood glucose profile and neurodevelopmental outcome at two years in neonatal hypoxic-ischaemic encephalopathy.

    LENUS (Irish Health Repository)

    Nadeem, Montasser

    2012-01-31

    BACKGROUND: To examine the blood glucose profile and the relationship between blood glucose levels and neurodevelopmental outcome in term infants with hypoxic-ischaemic encephalopathy. METHODS: Blood glucose values within 72 hours of birth were collected from 52 term infants with hypoxic-ischaemic encephalopathy. Hypoglycaemia [< 46.8 mg\\/dL (2.6 mmol\\/L)] and hyperglycaemia [> 150 mg\\/dL (8.3 mmol\\/L)] were correlated to neurodevelopmental outcome at 24 months of age. RESULTS: Four fifths of the 468 blood samples were in the normoglycaemic range (392\\/468:83.8%). Of the remaining 76 samples, 51.3% were in the hypoglycaemic range and (48.7%) were hyperglycaemic. A quarter of the hypoglycaemic samples (28.2%:11\\/39) and a third of the hyperglycaemic samples (32.4%:12\\/37) were recorded within the first 30 minutes of life. Mean (SD) blood glucose values did not differ between infants with normal and abnormal outcomes [4.89(2.28) mmol\\/L and 5.02(2.35) mmol\\/L, p value = 0.15] respectively. In term infants with hypoxic-ischaemic encephalopathy, early hypoglycaemia (between 0-6 hours of life) was associated with adverse outcome at 24 months of age [OR = 5.8, CI = 1.04-32)]. On multivariate analysis to adjust for grade of HIE this association was not statistically significant. Late hypoglycaemia (6-72 hours of life) was not associated with abnormal outcome [OR = 0.22, CI (0.04-1.14)]. The occurrence of hyperglycaemia was not associated with adverse outcome. CONCLUSION: During the first 72 hours of life, blood glucose profile in infants with hypoxic-ischaemic encephalopathy varies widely despite a management protocol. Early hypoglycaemia (0-6 hours of life) was associated with severe HIE, and thereby; adverse outcome.

  19. Higher blood glucose level associated with body mass index and gut microbiota in elderly people

    Science.gov (United States)

    Sepp, Epp; Kolk, Helgi; Lõivukene, Krista; Mikelsaar, Marika

    2014-01-01

    Background Some dominant bacterial divisions of the intestines have been linked to metabolic diseases such as overweight and diabetes. Objective A pilot study aimed to evaluate the relations between the culturable intestinal bacteria with body mass index (BMI) and some principal cellular and metabolic markers of blood in people older than 65. Design Altogether 38 generally healthy elderly people were recruited: ambulatory (n=19) and orthopedic surgery (n=19). Questionnaires on general health, anthropometric measurements, routine clinical and laboratory data, and quantitative composition of cultivable gut microbiota were performed. Results Blood glucose level was positively correlated with BMI (r=0.402; p=0.014). Higher blood glucose level had negative correlation with relative share of intestinal anaerobic bacteria such as bacteroides (r=−0.434; p=0.0076) and gram-positive anaerobic cocci (r=−0.364; p=0.027). In contrast, the relative share of bifidobacteria (r=0.383; p=0.019) and staphylococci (r=0.433; p=0.008) was positively correlated to blood glucose level. In elderly people, a higher blood glucose concentration was predicted by the reduction of the anaerobes’ proportion (adj. sex, age, and BMI R2=0.192, p=0.028) and that of Bacteroides sp. (adj. R2=0.309, p=0.016). Conclusion A tight interplay between increased BMI, level of blood glucose, and the reduced proportion of cultivable bacteroides is taking place in the gut microbiota of elderly people. PMID:24936169

  20. Higher blood glucose level associated with body mass index and gut microbiota in elderly people

    Directory of Open Access Journals (Sweden)

    Epp Sepp

    2014-06-01

    Full Text Available Background: Some dominant bacterial divisions of the intestines have been linked to metabolic diseases such as overweight and diabetes. Objective: A pilot study aimed to evaluate the relations between the culturable intestinal bacteria with body mass index (BMI and some principal cellular and metabolic markers of blood in people older than 65. Design: Altogether 38 generally healthy elderly people were recruited: ambulatory (n=19 and orthopedic surgery (n=19. Questionnaires on general health, anthropometric measurements, routine clinical and laboratory data, and quantitative composition of cultivable gut microbiota were performed. Results: Blood glucose level was positively correlated with BMI (r=0.402; p=0.014. Higher blood glucose level had negative correlation with relative share of intestinal anaerobic bacteria such as bacteroides (r=−0.434; p=0.0076 and gram-positive anaerobic cocci (r=−0.364; p=0.027. In contrast, the relative share of bifidobacteria (r=0.383; p=0.019 and staphylococci (r=0.433; p=0.008 was positively correlated to blood glucose level. In elderly people, a higher blood glucose concentration was predicted by the reduction of the anaerobes’ proportion (adj. sex, age, and BMI R2=0.192, p=0.028 and that of Bacteroides sp. (adj. R2=0.309, p=0.016. Conclusion: A tight interplay between increased BMI, level of blood glucose, and the reduced proportion of cultivable bacteroides is taking place in the gut microbiota of elderly people.

  1. Determination of time delay between blood and interstitial adipose tissue glucose concentration change by microdialysis in healthy volunteers

    NARCIS (Netherlands)

    Wientjes, KJC; Schoonen, AJM

    2001-01-01

    For the development and use of subcutaneous glucose sensors it is important to know the time lag between changes in blood glucose and subcutaneous interstitial glucose concentration. To determine the time lag we inserted a microdialysis probe into the abdominal subcutaneous adipose tissue of healthy

  2. Non-invasive blood glucose monitoring with Raman spectroscopy: prospects for device miniaturization

    Science.gov (United States)

    Wróbel, M. S.

    2016-01-01

    The number of patients with diabetes has reached over 350 million, and still continues to increase. The need for regular blood glucose monitoring sparks the interest in the development of modern detection technologies. One of those methods, which allows for noninvasive measurements, is Raman spectroscopy. The ability of infrared light to penetrate deep into tissues allows for obtaining measurements through the skin without its perforation. This paper presents the limitations and possibilities of non-invasive blood glucose monitoring with Raman spectroscopy. Especially focusing on the possibilities for device miniaturization. Such device incorporates a Raman spectrometer, a fiber-optical probe, and a computing device (microcontroller, smartphone, etc.) which calculates the glucose concentration using specialized algorithms. Simplification of device design, as well as turbidity correction technique and a new proposed method of synchronized detection are described.

  3. Correlation of salivary glucose, blood glucose and oral candidal carriage in the saliva of type 2 diabetics: A case-control study

    Directory of Open Access Journals (Sweden)

    Satish Kumar

    2014-01-01

    Full Text Available Objectives: To study the correlation between blood glucose levels and salivary glucose levels in type 2 diabetic patients, to study the relationship between salivary glucose levels and oral candidal carriage in type 2 diabetic patients and to determine whether salivary glucose levels could be used as a noninvasive tool for the measurement of glycemic control in type 2 diabetics. Study Design: The study population consisted of three groups: Group 1 consisted of 30 controlled diabetics and Group 2 consisted of 30 uncontrolled diabetics based on their random nonfasting plasma glucose levels. Group 3 consisted of 30 healthy controls. Two milliliters of peripheral blood was collected for the estimation of random nonfasting plasma glucose levels and glycosylated hemoglobin (HbA1c. Unstimulated saliva was collected for the estimation of salivary glucose. Saliva was collected by the oral rinse technique for the estimation of candidal counts. Results: The salivary glucose levels were significantly higher in controlled and uncontrolled diabetics when compared with controls. The salivary candidal carriage was also significantly higher in uncontrolled diabetics when compared with controlled diabetics and nondiabetic controls. The salivary glucose levels showed a significant correlation with blood glucose levels, suggesting that salivary glucose levels can be used as a monitoring tool for predicting glycemic control in diabetic patients. Conclusion: The present study found that estimation of salivary glucose levels can be used as a noninvasive, painless technique for the measurement of diabetic status of a patient in a dental set up. Increased salivary glucose levels leads to increased oral candidal carriage; therefore, oral diagnosticians are advised to screen the diabetic patients for any oral fungal infections and further management.

  4. The Effect of Blood Glucose Self-Monitoring Among Inmates With Diabetes.

    Science.gov (United States)

    Hunter Buskey, Robin N; Mathieson, Kathleen; Leafman, Joan S; Feinglos, Mark N

    2015-10-01

    The increasing prevalence and risk of complications from diabetes necessitate patient participation and attentiveness to select appropriate foods, perform regular physical activity, and be active in diabetes management and self-maintenance. Diabetes is often largely asymptomatic; consequently, early diagnosis and treatment are necessary. Inmates are a unique population challenged by the increased prevalence of chronic conditions including diabetes. Diabetes standards for inmates contain diagnostic and treatment management guidelines that incorporate personal glucose monitoring for insulin users. In December 2009, the Federal Bureau of Prisons initiated a program to distribute glucose meters to insulin-dependent inmates to facilitate self-monitoring blood glucose. The purpose of this study was to evaluate the effect of these glucose meters on hemoglobin A1c levels. PMID:26276137

  5. Comprehensive Experiment--Clinical Biochemistry: Determination of Blood Glucose and Triglycerides in Normal and Diabetic Rats

    Science.gov (United States)

    Jiao, Li; Xiujuan, Shi; Juan, Wang; Song, Jia; Lei, Xu; Guotong, Xu; Lixia, Lu

    2015-01-01

    For second year medical students, we redesigned an original laboratory experiment and developed a combined research-teaching clinical biochemistry experiment. Using an established diabetic rat model to detect blood glucose and triglycerides, the students participate in the entire experimental process, which is not normally experienced during a…

  6. Blood Glucose Monitoring as a Teaching Tool for Endocrinology: A New Perspective

    Science.gov (United States)

    Moats, Robert K., II

    2009-01-01

    The education of new allied health professionals and nurses in proper endocrine evaluation and care has become critical in recent years, especially considering the greatly increased prevalence of diabetes in adults and children. The evaluation of blood glucose levels in human volunteers over time is a powerful teaching tool for endocrinology that…

  7. Bihormonal model predictive control of blood glucose in people with type 1 diabetes

    DEFF Research Database (Denmark)

    Batora, Vladimir; Tarnik, Marian; Murgas, Jan;

    2014-01-01

    In this paper we present a bihormonal control system that controls blood glucose in people with type 1 diabetes (T1D). We use insulin together with glucagon to mitigate the negative effects of hyper- and hypoglycemia. The system consists of a Kalman filter, a micro-bolus insulin and glucagon infu...

  8. Higher Blood Glucose within the Normal Range Is Associated with More Severe Strokes

    DEFF Research Database (Denmark)

    Martin, Rolf J; Ratan, Rajiv R; Reding, Michael J;

    2012-01-01

    in normoglycemic patients with ischemic stroke in a median of 7 days after stroke when the initial glycemic stress response has resolved. Method and Material. Included were 361 nondiabetic ischemic stroke patients with admission fasting blood glucose within 70-130 mg/dL admitted into an acute stroke rehabilitation...

  9. Self-monitoring of blood glucose in tablet-treated type 2 diabetic patients (ZODIAC)

    NARCIS (Netherlands)

    Kleefstra, Nanno; Hortensius, J.; Logtenberg, Susan; Slingerland, R. J.; Groenier, K. H.; Houweling, S. T.; Gans, R. O. B.; van Ballegooie, E; Bilo, H. J. G.

    2010-01-01

    Background: Whether self-monitoring of blood glucose (SMBG) improves glycaemic control in patients with type 2 diabetes mellitus (T2DM) not using insulin is questionable. Our aim was to investigate the effects of SMBG in patients with T2DM who were in persistent moderate glycaemic control whilst not

  10. What do professionals recommend regarding the frequency of self-monitoring of blood glucose?

    NARCIS (Netherlands)

    Hortensius, J.; Kleefstra, N.; Houweling, S. T.; van der Bijl, J. J.; Gans, R. O. B.; Bilo, H. J. G.

    2012-01-01

    Background: Patients' adherence to guidelines regarding self-monitoring of blood glucose (SMBG) is limited. However, there are no previous reports about the recommendations that are given in clinical practice concerning SMBG. The aim of this study was to investigate what healthcare providers recomme

  11. Cinnamon intake lowers fasting blood glucose: an updated meta-analysis

    Science.gov (United States)

    OBJECTIVE – To determine if meta-analysis of recent clinical studies of cinnamon intake by people with Type II diabetes and/or prediabetes resulted in significant changes in fasting blood glucose. RESEARCH DESIGN AND METHODS -- Published clinical studies were identified using a literature search (P...

  12. A Method for Manipulating Blood Glucose and Measuring Resulting Changes in Cognitive Accessibility of Target Stimuli.

    Science.gov (United States)

    Prokosch, Marjorie L; Hill, Sarah E

    2016-01-01

    Much research in social psychology has investigated the impact of bodily energy need on cognition and decision-making. As such, blood glucose, the body's primary energy source, has been of special interest to researchers for years. Fluctuations in blood glucose have been linked to a variety of changes in cognitive and behavioral processes, such as self-control, political attitudes, and eating behavior. To help meet growing interest in the links between bodily energy need and these processes, this manuscript offers a simple methodology to experimentally manipulate blood glucose using a fasting procedure followed by administration of a sugar-sweetened, unsweetened, or artificially-sweetened beverage. This is followed by presentation of a method for measuring resulting changes in implicit cognition using a lexical decision-task. In this task, participants are asked to identify whether strings of letters are words or non-words and response latencies are recorded. Sample results from a recent publication are presented as an example of the applications for the experimental manipulation of blood glucose and the lexical decision task measures. PMID:27585282

  13. Analysis on blood glucose excursions in well-controlled patients with type 2 diabetes mellitus

    Institute of Scientific and Technical Information of China (English)

    Deng Wuquan; Yu Qiongwu; Wang Fuhua; Ai Zhihua; Chen Bing

    2009-01-01

    Objective: To probe glycemic excursions in type 2 diabetic patients whose hemoglobin A1c (HbA1c) was kept ≤6.0%.Methods: Totally 36 cases with type 2 diabetes (T2DM) with HbA1c≤6.0% and 30 cases with normal glucose tolerance (NGT) from December 2005 to December 2007 in our department were subjected prospectively. Continuous glucose monitoring system (CGMS) was employed to record their continuous blood glucose level for 3 d. The blood glucose profiles including the mean blood glucose (MBG), standard differentiation (SD), mean amplitude of glycemic excursions (MAGE) and absolute means of daily differences (MODD) were analyzed. Results: T2DM group had obviously postprandial hyperglycemia, in about 2 h after meal, especially after breakfast. Fifty-two hypoglycemic episodes occurred during the monitoring period in T2DM groups, of which 73.1% (38 episodes) were absence of symptomatic hypoglycemia with the lowest value of blood glucose only 2.0 mmol/L. And 20 episodes took place during the day hours, while 32 episodes observed during the night hours. Compared with NGT groups, SD, MAGE and MODD were all significantly higher in T2DM groups. MBG was significantly correlated with HbA1c in T2DM groups, but SD, MAGE, NGE and MODD were all independent of HbA1c. MAGE was independent of MODD. Conclusion: The amplitude of glycemic excursions is higher in normol-controlled T2DM groups than the NGT groups.Thus ideally glycemic control is not only to make HbA1c reach standard, but also to lessen glycemic excursions and reduce hypoglycemia episodes.

  14. Additional benefit of higher dose green tea in lowering postprandial blood glucose

    Directory of Open Access Journals (Sweden)

    Rita Lahirin

    2015-07-01

    Full Text Available Background: Green tea contains catechins that have inhibitory effects on amylase, sucrase, and sodium-dependent glucose transporter (SGLT which result in lowering of postprandial blood glucose (PBG. This beneficial effect has been widely demonstrated using the usual dose (UD of green tea preparation. Our study was aimed to explore futher lowering of PBG using high dose (HD of green tea in healthy adolescents.Methods: 24 subjects received 100 mL infusion of either 0.67 or 3.33 grams of green tea with test meal. Fasting, PBG at 30, 60, 120 minutes were measured. Subjects were cross-overed after wash out. PBG and its incremental area under the curve (IAUC difference between groups were analyzed with paired T-test. Cathecin contents of tea were measured using high-performance liquid chromatography (HPLC.Results: The PBG of HD group was lower compared to UD (at 60 minutes =113.70 ± 13.20 vs 124.16 ± 8.17 mg/dL, p = 0.005; at 120 minutes = 88.95 ± 6.13 vs 105.25 ± 13.85 mg/dL, p < 0.001. The IAUC of HD was also found to be lower compared to UD (2055.0 vs 3411.9 min.mg/dL, p < 0.001.Conclusion: Additional benefit of lowering PBG can be achieved by using higher dose of green tea. This study recommends preparing higher dose of green tea drinks for better control of PBG.

  15. Impairment of brain endothelial glucose transporter by methamphetamine causes blood-brain barrier dysfunction

    Directory of Open Access Journals (Sweden)

    Murrin L Charles

    2011-03-01

    Full Text Available Abstract Background Methamphetamine (METH, an addictive psycho-stimulant drug with euphoric effect is known to cause neurotoxicity due to oxidative stress, dopamine accumulation and glial cell activation. Here we hypothesized that METH-induced interference of glucose uptake and transport at the endothelium can disrupt the energy requirement of the blood-brain barrier (BBB function and integrity. We undertake this study because there is no report of METH effects on glucose uptake and transport across the blood-brain barrier (BBB to date. Results In this study, we demonstrate that METH-induced disruption of glucose uptake by endothelium lead to BBB dysfunction. Our data indicate that a low concentration of METH (20 μM increased the expression of glucose transporter protein-1 (GLUT1 in primary human brain endothelial cell (hBEC, main component of BBB without affecting the glucose uptake. A high concentration of 200 μM of METH decreased both the glucose uptake and GLUT1 protein levels in hBEC culture. Transcription process appeared to regulate the changes in METH-induced GLUT1 expression. METH-induced decrease in GLUT1 protein level was associated with reduction in BBB tight junction protein occludin and zonula occludens-1. Functional assessment of the trans-endothelial electrical resistance of the cell monolayers and permeability of dye tracers in animal model validated the pharmacokinetics and molecular findings that inhibition of glucose uptake by GLUT1 inhibitor cytochalasin B (CB aggravated the METH-induced disruption of the BBB integrity. Application of acetyl-L-carnitine suppressed the effects of METH on glucose uptake and BBB function. Conclusion Our findings suggest that impairment of GLUT1 at the brain endothelium by METH may contribute to energy-associated disruption of tight junction assembly and loss of BBB integrity.

  16. The effect of food with different glycaemic index on the blood glucose level

    Directory of Open Access Journals (Sweden)

    Lenka Kouřimská

    2015-08-01

    Full Text Available Blood glucose levels are affected by many factors including the type of foods consumed, processing technology and cooking method. Hormone insulin lowers blood glucose to its constant level, while glucagon, growth hormone, adrenalin and glucocorticoids have the opposite effect. High steepness of the blood glucose level rise after meals may be unfavourable for the organism. Sugars are transferred into the blood at different speeds according to the type of food. Therefore the aim of this study was to confirm experimentally the effect of food on blood glucose levels in men and women of different ages. Two types of low, medium and high-glycaemic index (GI foods were given to 4 men and 4 women of different age (from 35 to 65 years. All volunteers were healthy, slightly overweight, and without any regular sporting activity. None of them had any idea about their daily carbohydrates consumption and what the term glycaemic index meant. The volunteers came to the GI determination fasted in the morning. Their rise in blood glucose level was monitored by glucometer before the meal and after 1 and 2 hours of the consumption of baked potatoes (GI 85, white bread bun (GI 70, boiled potatoes (GI 64, rye bread (GI 62, potato dumplings (GI 52 and white cooked spaghetti (GI 41. Fasting blood sugar levels of volunteers highly depended on their age (p <0.0001 and gender (p <0.0001. The blood glucose values increased with age and were higher in men than in women. Significant influence of food GI on blood glucose levels in both men and women in all the age categories was observed (p <0.0001. An interaction between age and gender was also statistically highly significant (p <0.0001. One hour after consuming food the blood glucose values were significantly different from the values of fasting (p = 0.0035. The differences of these values did not depend on the age (p = 0.0574 and sex (p = 0.8256 of volunteers, but there was a significant difference on the GI value of food

  17. Analysis of oral glucose tolerance test in pregnant women with abnormal glucose metabolism

    Institute of Scientific and Technical Information of China (English)

    YANG Hui-xia; GAO Xue-lian; DONG Yue; SHI Chun-yan

    2005-01-01

    Background Due to the controversy of the oral glucose tolerance test (OGTT), diagnostic criteria for gestational diabetes mellitus (GDM) in the world and researches on GDM remain undeveloped in China. American Diabetes Association recently recommended the clinicians to diagnose GDM by OGTT results without the third-hour glucose value. This new criteria has not been used in China. Research on the value and sensitivity of the criteria in detecting GDM is rare. The aim of our study is to analyze the characteristics of OGTT in Chinese women with GDM or gestational impaired glucose tolerance (GIGT) and to evaluate the effect of omission of the third-hour plasma glucose (PG) level in OGTT on the sensitivity of diagnosing GDM and GIGT, and the relationship between PG values of 50 g GCT or OGTT and insulin therapy. Methods A retrospective analysis was performed on medical records of 647 cases with GDM from January 1, 1989 to December 31, 2002, and 233 with GIGT. Among 647 cases of GDM, 535 cases were diagnosed by 75 g OGTT. All OGTT results including 535 cases of GDM and 233 patients with GIGT were evaluated. Results There were 112 cases of GDM diagnosed by elevated fasting PG (FPG) without OGTT performed. Of 535 cases of GDM diagnosed by OGTT, 49.2% (263/535) women had FPG value ≥5.8 mmol/L; 90.1% (482/535) women with 1-hour PG values ≥10.6 mmol/L; 64.7% (359/535) with 2-hour PG levels ≥9.2 mmol/L. There were only 114 cases (21.3%) with abnormal 3-hour PG levels among 535 women with OGTT. Among those with abnormal 3-hour PG level, 49.1% (56/114) had abnormal glucose values in the other three points of OGTT, and 34.2% (39/114) with two other abnormal values of OGTT. Our study showed that omission of the 3-hour PG of OGTT only missed 19 cases of GDM and they would be diagnosed as GIGT. Among the 233 women with GIGT, only 4 cases had abnormal 3-hour PG. So, omission of the third-hour glucose value of OGTT only resulted in failure to diagnose 3.6% (19/535) women with

  18. 21 CFR 640.53 - Testing the blood.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 7 2010-04-01 2010-04-01 false Testing the blood. 640.53 Section 640.53 Food and... ADDITIONAL STANDARDS FOR HUMAN BLOOD AND BLOOD PRODUCTS Cryoprecipitate § 640.53 Testing the blood. (a) Blood... sample of blood collected at the time of collecting the source blood, and such sample container shall...

  19. Blood concentrations of lactate, glucose and corticosterone in dispersing hatchling sea turtles

    Directory of Open Access Journals (Sweden)

    Carla M. Pereira

    2012-11-01

    Natal dispersal of sea turtles is an energetically demanding activity that is fuelled primarily by aerobic metabolism. However, during intense exercise reptiles can use anaerobic metabolism to supplement their energy requirements. We assessed anaerobic metabolism in dispersing hatchling loggerhead and flatback turtles by measuring the concentrations of blood lactate during crawling and at different times during the first four hours of their frenzy swim. We also measured concentrations of blood glucose and corticosterone. Blood lactate (12.13 to 2.03 mmol/L, glucose (6.25 to 3.8 mmol/L and corticosterone (8.13 to 2.01 ng/mL concentrations decreased significantly over time in both loggerhead and flatback hatchlings and no significant differences were found between the species. These results indicate that anaerobic metabolism makes a significant contribution to the dispersal phase of hatchling sea turtles during the beach crawl and the first few hours of the frenzy swim.

  20. Effects of electroacupuncture on microcirculatory blood flow and glucose transporter function in the hippocampus

    Institute of Scientific and Technical Information of China (English)

    Yan Lu; Bingbing Han; Shijun Wang

    2011-01-01

    Nerve cell metabolism in post brain ischemia depends on increased microcirculation perfusion and transport function of microvascular endothelial cells. In the present study, a rat model of middle cerebral artery occlusion was established to investigate the influence of electroacupuncture(EA)on hippocampal CA1 cerebral blood flow and glucose transporter 1(GLUT1)expression in the microvascular endothelial cp.lls. Following EA at Neiguan(PC 6), the cerebral blood flow in the ischemic hippocampal CA1 region was significantly elevated, the number and microvascular integrated absorbance of the GLUTl-positive cells were significantly increased, nerve cell damage was ameliorated, and GLUT1 protein expression in the ischemic hippocampus was significantly increased. Results demonstrate that EA increased the cerebral blood flow of the hippocampal CA1 region and improved the glucose transport function, thereby attenuating neuronal injuries.

  1. Analytical model for real time, noninvasive estimation of blood glucose level.

    Science.gov (United States)

    Adhyapak, Anoop; Sidley, Matthew; Venkataraman, Jayanti

    2014-01-01

    The paper presents an analytical model to estimate blood glucose level from measurements made non-invasively and in real time by an antenna strapped to a patient's wrist. Some promising success has been shown by the RIT ETA Lab research group that an antenna's resonant frequency can track, in real time, changes in glucose concentration. Based on an in-vitro study of blood samples of diabetic patients, the paper presents a modified Cole-Cole model that incorporates a factor to represent the change in glucose level. A calibration technique using the input impedance technique is discussed and the results show a good estimation as compared to the glucose meter readings. An alternate calibration methodology has been developed that is based on the shift in the antenna resonant frequency using an equivalent circuit model containing a shunt capacitor to represent the shift in resonant frequency with changing glucose levels. Work under progress is the optimization of the technique with a larger sample of patients.

  2. A signal processing application for evaluating self-monitoring blood glucose strategies in a software agent model.

    Science.gov (United States)

    Wang, Zhanle; Paranjape, Raman

    2015-07-01

    We propose the signal processing technique of calculating a cross-correlation function and an average deviation between the continuous blood glucose and the interpolation of limited blood glucose samples to evaluate blood glucose monitoring frequency in a self-aware patient software agent model. The diabetic patient software agent model [1] is a 24-h circadian, self-aware, stochastic model of a diabetic patient's blood glucose levels in a software agent environment. The purpose of this work is to apply a signal processing technique to assist patients and physicians in understanding the extent of a patient's illness using a limited number of blood glucose samples. A second purpose of this work is to determine an appropriate blood glucose monitoring frequency in order to have a minimum number of samples taken that still provide a good understanding of the patient's blood glucose levels. For society in general, the monitoring cost of diabetes is an extremely important issue, and these costs can vary tremendously depending on monitoring approaches and monitoring frequencies. Due to the cost and discomfort associated with blood glucose monitoring, today, patients expect monitoring frequencies specific to their health profile. The proposed method quantitatively assesses various monitoring protocols (from 6 times per day to 1 time per week) in nine predefined categories of patient agents in terms of risk factors of health status and age. Simulation results show that sampling 6 times per day is excessive, and not necessary for understanding the dynamics of the continuous signal in the experiments. In addition, patient agents in certain conditions only need to sample their blood glucose 1 time per week to have a good understanding of the characteristics of their blood glucose. Finally, an evaluation scenario is developed to visualize this concept, in which appropriate monitoring frequencies are shown based on the particular conditions of patient agents. This base line can

  3. Monitoring of glucose, salt and pure water in human whole blood: An in vitro study.

    Science.gov (United States)

    Imran, Muhammad; Ullah, Hafeez; Akhtar, Munir; Sial, Muhammad Aslam; Ahmed, Ejaz; Durr-E-Sabeeh; Ahmad, Mukhtar; Hussain, Fayyaz

    2016-07-01

    Designing and implementation of non-invasive methods for glucose monitoring in blood is main focus of biomedical scientists to provide a relief from skin puncturing of diabete patient. The objective of this research work is to investigate the shape deformations and the aggregation of red blood cells (RBCs) in the human blood after addition of three different analytes i) (0mM-400mM: Range) of glucose (C(6)H(12)O(6)), ii) (0mM-400mM: range) of pure salt (NaCl) and iii) (0mM- 350mM: range) of pure water (H(2)O). We have observed that the changes in the shape of individual cells from biconcave discs to spherical shapes and eventually the lysis of the cells at optimum concentration of glucose, salts and pure water. This demonstration also provides a base line to facilitate diabetes during partial diagnosis and monitoring of the glucose levels qualitatively both in research laboratories and clinical environment. PMID:27393437

  4. [Modification of fasting blood glucose in adults with diabetes mellitus type 2 after regular soda and diet soda intake in the State of Querétaro, Mexico].

    Science.gov (United States)

    Olalde-Mendoza, Liliana; Moreno-González, Yazmín Esmeralda

    2013-06-01

    The objective of the study was to compare the modification of fasting blood glucose in adults with diabetes mellitus type 2 after intake of regular soda and diet soda. We conducted a randomized clinical trial in clinics of Instituto Mexicano del Seguro Social in Querétaro, México. We included 80 patients with diabetes (mean weight 74.2 +/- 13.66, BMI 30.5 +/- 4.305, waist 98.2 +/- 12.9 and time evolution of diabetes 3.8 +/- 3.009) who were asked to come with fasting for 8 hours and without taking any medicine before testing. They were divided into two groups of 40 subjects, to whom was measured fasting blood glucose after the ingestion of 200 ml of diet soda (with aspartame and acesulfame potassium) or regular soda (without sweetener) we measure glucose at 10, 15 and 30 minutes. For statistical analysis performed we used Student's t-test for dependent and independent samples, and paired t-test, and chi square test (chi2). Capillary glucose levels at 10 minutes were -34.52 and -25.41%, at 15 minutes -48.8 and -36.2% and at 30 minutes 57.75 and 43.6% of absolute and relative differences, with p = 0.000. In conclusion, according to the observations, diet soda doesn't increased blood glucose levels, with a significant difference in fasting decreased at 30 minutes.

  5. [Modification of fasting blood glucose in adults with diabetes mellitus type 2 after regular soda and diet soda intake in the State of Querétaro, Mexico].

    Science.gov (United States)

    Olalde-Mendoza, Liliana; Moreno-González, Yazmín Esmeralda

    2013-06-01

    The objective of the study was to compare the modification of fasting blood glucose in adults with diabetes mellitus type 2 after intake of regular soda and diet soda. We conducted a randomized clinical trial in clinics of Instituto Mexicano del Seguro Social in Querétaro, México. We included 80 patients with diabetes (mean weight 74.2 +/- 13.66, BMI 30.5 +/- 4.305, waist 98.2 +/- 12.9 and time evolution of diabetes 3.8 +/- 3.009) who were asked to come with fasting for 8 hours and without taking any medicine before testing. They were divided into two groups of 40 subjects, to whom was measured fasting blood glucose after the ingestion of 200 ml of diet soda (with aspartame and acesulfame potassium) or regular soda (without sweetener) we measure glucose at 10, 15 and 30 minutes. For statistical analysis performed we used Student's t-test for dependent and independent samples, and paired t-test, and chi square test (chi2). Capillary glucose levels at 10 minutes were -34.52 and -25.41%, at 15 minutes -48.8 and -36.2% and at 30 minutes 57.75 and 43.6% of absolute and relative differences, with p = 0.000. In conclusion, according to the observations, diet soda doesn't increased blood glucose levels, with a significant difference in fasting decreased at 30 minutes. PMID:24934070

  6. Blood glucose lowering effect of ophiopogonis tuber extract and mechanism of anti-insulin-resistance

    Directory of Open Access Journals (Sweden)

    Meng NING

    2013-01-01

    Full Text Available Objective  To study the hypoglycemic effect and insulin sensitization mechanism of ophiopogonis tuber extracts on the 3T3-L1-induced adipocytes, and also in rats with reproduction of type 2 diabetes mellitus (T2DM. Methods  3T3-L1 cells were induced and differentiated into adipocytes. After the intervention with ophiopogonpolysaccharide (OPSR and ophiopogonin (OPG, glucose consuming rate was detected for screening the extracts which may have effective hypoglycemic effects. The insulin resistance (IR adipocyte model was established by dexamethasone induction, and then it was treated with OPSR. The protein expression levels of leptin, adiponectin and resistin were detected by Western blotting. The T2DM rat model was reproduced and then treated with OPSR for 4 weeks. Body weight (BW, triglyeride (TG, fasting blood glucose (FBG and fasting insulin (FINs of the rats were measured respectively. Results  OPSR in dosage of 0.5-50mg/L promoted glucose consumption of adipocytes in a dose-dependent manner, the glucose consumption ratios were 32.27%, 75.14% and 90.47% respectively. OPG of 50mg/L showed very weak activity with glucose consumption ratio of only 8.49%. OPSR could significantly promote the protein expression of leptin and adiponectin, and showed an inhibitory effect on the protein expression of resistin (P<0.05. After treatment with OPSR for 4 weeks, the BW of rats increased obviously, while TG, FBG and HOMA-IR decreased significantly (P<0.05 or P<0.01. Conclusions  OPSR may promote glucose transport and utilization of adipocytes, decrease the level of FBG and TG, and improve the condition of IR in T2DM rats. The mechanism of blood glucose lowering effect may be attributed to secretion of adipokines, such as leptin, adiponectin and resistin by IR adipocytes.

  7. Design of Multiscale low-power portable blood glucose meter%宽量程低功耗便携式血糖仪设计

    Institute of Scientific and Technical Information of China (English)

    孔中宝; 寇亚青

    2013-01-01

      介绍了一种宽量程低功耗的便携式血糖仪设计。本设计基于酶电转换检测原理,利用TI公司MSP430FG439低功耗单片机的OA、ADC、温度检测及FLASH等内部模块,通过对微电流宽量程放大,高精度数模转换和环境温度校正,能精准的测试出血糖浓度值,并具有检测值显示存储和历史平均值的查询功能。%A design on wide-range and low-power consumption portable blood glucose meter is introduced . The design based on glucose oxidase electrode detection principle takes the MSP430FG439 low-power microcontrol er from TI company,which we use the internal module of OA ,ADC ,temperature testing and flash memory .The presented blood glucose meter through magnifying the measuring range of microcurrent and high precision ADC and puting right ambient temperature to make the blood sugar concentration be tested by the bood glucose meter accurately.In addition,the presented blood glucose meter can display ang store the detection data and historical data query function.

  8. [Multicenter evaluation of the reliability of five blood glucose monitoring systems].

    Science.gov (United States)

    Jday-Daly, Ismahen; Augereau-Vacher, Christine; De Curraize, Claire; Fonfrède, Michèle; Lefevre, Guillaume; Lacour, Bernard; Hennequin-Le Meur, Carole

    2011-01-01

    As part of a tender AP-HP Paris Hospitals, an assessment of the reliability record of five blood glucose monitoring systems (BGMSs) (Optium Xceed (Abbott), Contour TS (Bayer), One Touch Ultra (Lifescan), Stat Strip Xpress (Nova) and Accu Check (Roche) and an evaluation of their sensitivity to changes in hematocrit were conducted in 4 hospitals of Paris. In terms of inaccuracy, all BGMSs have submitted CV repetability under the limits of acceptability. One BGMS (Lifescan) presented a CV of reproducibility outside limit of acceptability (13.1%). The inaccuracy was measured by a comparison method on multiparameter analyser relative to the hexokinase method for two sites, the glucose oxidase for the two others. The coefficients of correlation varied from 0.8405 to 0.9303. However, according to both defined acceptability criteria (absolute value difference between the result acquired on analyzer and those determined with the BGMS), the percentage of results outside acceptability was above 20% for two BGMSs (Abbott and Lifescan). Similarly, a net effect of changes in hematocrit was observed on the results of those two BGMSs. BGMS Nova was the most reliable, because of the correction device for hematocrit and blank substractions owed to interferences. In terms of expertise, BGMSs Nova and Roche have been selected with the best analytical performance and practicability satisfactory. In the future, accreditation with standard NF/EN 22870 requested for point of care testing, will require a close collaboration between biologists and clinicians to establish a system of strict quality control to detect deviations of these BGMSs. PMID:21463996

  9. Fluorescent blood glucose monitor by hemin-functionalized graphene quantum dots based sensing system

    Energy Technology Data Exchange (ETDEWEB)

    He, Yuezhen; Wang, Xiaoxun; Sun, Jian; Jiao, Shoufeng; Chen, Hongqi; Gao, Feng; Wang, Lun, E-mail: wanglun@mail.ahnu.edu.cn

    2014-01-31

    Graphical abstract: -- Highlights: •Hemin is assembled onto the surfaces of graphene quantum dots (GQDs). •With the aid of hemin, H{sub 2}O{sub 2} could quench the FL signal of GQDs obviously. •Based on this effect, a fluorescent platform is proposed for the sensing of glucose. •The proposed method provides a new pathway to explore practical application of GQDs. -- Abstract: In the present work, a highly sensitive and specific fluorescent biosensor for blood glucose monitoring is developed based on hemin-functionalized graphene quantum dots (GQDs) and glucose oxidase (GOx) system. The GQDs which are simply prepared by pyrolyzing citric acid exhibit strong fluorescence and good water-solubility. Due to the noncovalent assembly between hemin and GQDs, the addition of hemin can make hydrogen peroxide (H{sub 2}O{sub 2}) to destroy the passivated surface of GQDs, leading to significant fluorescence quenching of GQDs. Based on this effect, a novel fluorescent platform is proposed for the sensing of glucose. Under the optimized conditions, the linear range of glucose is from 9 to 300 μM, and the limit of detection is 0.1 μM. As unique properties of GQDs, the proposed biosensor is green, simple, cost-efficient, and it is successfully applied to the determination of glucose in human serum. In addition, the proposed method provides a new pathway to further design the biosensors based on the assembly of GQDs with hemin for detection of biomolecules.

  10. Acknowledging the results of blood tests

    DEFF Research Database (Denmark)

    Torkilsheyggi, Arnvør Martinsdottir á; Hertzum, Morten

    At the studied hospital, physicians from the Medical and Surgical Departments work some of their shifts in the Emergency Department (ED). Though icons showing the blood-test process were introduced on electronic whiteboards in the ED, these icons did not lead to increased attention to test...

  11. Clinical significance of determination of serum leptin, insulin levels and blood sugar in pregnant women with glucose metabolism disturbances

    International Nuclear Information System (INIS)

    Objective: To investigate the changes of serum leptin, insulin levels and blood sugar contents in pregnant women with gestational glucose metabolism disturbances. Methods: Fasting and 3h after oral 50g glucose serum levels of leptin were measured with RIA in 36 pregnant women with glucose metabolism disturbances (gestational diabetes mellitus or gestational impaired glucose tolerance) and 34 controls. Also, fasting serum insulin levels (with CLIA) and blood sugar contents 1h after oral 50 glucose (with glucose oxidase method) were determined in all these subjects. Results: 1. Serum levels of leptin in pregnant women with glucose metabolism disturbances were 14.9 ± 4.3 μg/L (vs controls 9.8 ± 1.7 μg/L, P<0.01). 2. The serum levels of insulin and 1 h post - 50g glucose blood sugar contents in pregnant women with glucose metabolism disturbances were 12.9±4.3mU/L and 11.0±1.4mmol/L respectively, which were both significantly positively correlated with the serum leptin levels (r=0.835, r=0.758 respectively) (vs levels in controls: 8.45±3.0mU/L and 7.84±1.3mmol/L). Conclusion: Elevation of fasting serum levels of leptin was demonstrated in pregnant women with glucose metabolism disturbances and the level of leptin was positively correlated with that of insulin and blood sugar. (authors)

  12. Quantitative classification of HbA1C and blood glucose level for diabetes diagnosis using neural networks

    International Nuclear Information System (INIS)

    In this study, artificial neural network structures were used for the quantitative classification of Haemoglobin A1C and blood glucose level for diabetes diagnosis as a non-invasive measurement technique. The neural network structures make inferences from the relationship between the palm perspiration and blood data values. For this purpose, feed forward multilayer, Elman, and radial basis neural network structures were used. The quartz crystal microbalance type and humidity sensors were used for the detection of palm perspiration rates. Total 297 volunteer's data is used in this study. Three quarters of the data was used to train the neural networks. The remaining data were used as test data. The best results for the quantitative classification were obtained from the feed forward NN structure for the detection of the glucose and HbA1C level quantities. And, the performances of all neural networks for the HbA1C value were better than the performances of these neural networks for the glucose level.

  13. Cattle temperament influences metabolism: metabolic response to glucose tolerance and insulin sensitivity tests in beef steers.

    Science.gov (United States)

    Burdick Sanchez, N C; Carroll, J A; Broadway, P R; Hughes, H D; Roberts, S L; Richeson, J T; Schmidt, T B; Vann, R C

    2016-07-01

    Cattle temperament, defined as the reactivity of cattle to humans or novel environments, can greatly influence several physiological systems in the body, including immunity, stress, and most recently discovered, metabolism. Greater circulating concentrations of nonesterified fatty acids (NEFAs) found in temperamental cattle suggest that temperamental cattle are metabolically different than calm cattle. Further, elevated NEFA concentrations have been reported to influence insulin sensitivity. Therefore, the objective of this study was to determine whether cattle temperament would influence the metabolic response to a glucose tolerance test (GTT) and insulin sensitivity test (IST). Angus-cross steers (16 calm and 15 temperamental; 216 ± 6 kg BW) were selected based on temperament score measured at weaning. On day 1, steers were moved into indoor stanchions to allow measurement of individual ad libitum feed intake. On day 6, steers were fitted with indwelling rectal temperature probes and jugular catheters. At 9 AM on day 7, steers received the GTT (0.5-mL/kg BW of a 50% dextrose solution), and at 2 PM on day 7, steers received the IST (2.5 IU bovine insulin/kg BW). Blood samples were collected and serum isolated at -60, -45, -30, -15, 0, 10, 20, 30, 45, 60, 90, 120, and 150 min relative to each challenge. Serum was stored at -80°C until analyzed for cortisol, glucose, NEFA, and blood urea nitrogen concentrations. All variables changed over time (P < 0.01). For the duration of the study, temperamental steers maintained greater (P < 0.01) serum NEFA and less (P ≤ 0.01) serum blood urea nitrogen and insulin sensitivity (calculated using Revised Quantitative Insulin Sensitivity Check Index) compared with calm steers. During the GTT, temperamental steers had greater (P < 0.01) serum glucose, yet decreased (P = 0.03) serum insulin and (P < 0.01) serum insulin: serum glucose compared to calm cattle. During the IST, temperamental steers had greater (P < 0.01) serum

  14. Blood glucose regulation during fasting in rats under food restriction since birth

    Directory of Open Access Journals (Sweden)

    Adriana de Souza Vitoriano

    2011-02-01

    Full Text Available The effect of severe food restriction since birth on regulation of fasting glycemia in male Wistar rats was investigated. The control group (CG had free supply of chow, while the restriction group (RG received 50% of the amount ingested by the CG. The experiments were done in adult (60 days overnight fasted rats in which glycemia, liver free glucose levels and hepatic glycogen concentration were measured. In part of the experiments in situ liver perfusion was done. The results showed that livers from the RG had higher glycogenolysis rates but lower gluconeogenesis rates from L-alanine (10 mM. Since RG showed maintained glycemia during fasting, it could be concluded that livers from RG produced glucose preferentially from glycogenolysis in detriment of gluconeogenesis. These findings demonstrated that in spite of severe caloric restriction, the metabolic adaptations of the liver did exist to assure the maintenance of blood glucose for brain supply during fasting.

  15. High activity enables life on a high-sugar diet: blood glucose regulation in nectar-feeding bats.

    Science.gov (United States)

    Kelm, Detlev H; Simon, Ralph; Kuhlow, Doreen; Voigt, Christian C; Ristow, Michael

    2011-12-01

    High blood glucose levels caused by excessive sugar consumption are detrimental to mammalian health and life expectancy. Despite consuming vast quantities of sugar-rich floral nectar, nectar-feeding bats are long-lived, provoking the question of how they regulate blood glucose. We investigated blood glucose levels in nectar-feeding bats (Glossophaga soricina) in experiments in which we varied the amount of dietary sugar or flight time. Blood glucose levels increased with the quantity of glucose ingested and exceeded 25 mmol l(-1) blood in resting bats, which is among the highest values ever recorded in mammals fed sugar quantities similar to their natural diet. During normal feeding, blood glucose values decreased with increasing flight time, but only fell to expected values when bats spent 75 per cent of their time airborne. Either nectar-feeding bats have evolved mechanisms to avoid negative health effects of hyperglycaemia, or high activity is key to balancing blood glucose levels during foraging. We suggest that the coevolutionary specialization of bats towards a nectar diet was supported by the high activity and elevated metabolic rates of these bats. High activity may have conferred benefits to the bats in terms of behavioural interactions and foraging success, and is simultaneously likely to have increased their efficiency as plant pollinators.

  16. 氯氮平与维思通对精神分裂患者血糖影响的比较%Different effects of clozapine and risperidone on levels of blood glucose in patients with schizophrenia

    Institute of Scientific and Technical Information of China (English)

    曹栋; 谢世平

    2001-01-01

    Objective To investigate the different effects of clozapine and risperidone on levels of blood glucose in patients with schizophrenia. Method 200 qualified cases selected from psychiatric department were divided into two groups randomly, of which 100 cases accepted the treatment with clozapine and the other 100 cases with risperidone. Blood glucose tests were used before treatment ,4 weeks after treatment and 8 weeks after treatment Results There was significantly higher blood glucose level in clozapine- treated group than in risperidone- treated group after 4 or 8 weeks treatment. The number of cases who had elevated blood glucose level (>6.1 mmol/L) in clozapine- treated group was significantly more than in risperidone- treated group. Conclusion The glucoregulatory abnormality which leads to glucose elevation in clozapine- treated patients is greater than in risperidone- treated patients. Additional motivation to clinical monitor for antipsychotic treatment- related hyperglycemia is indicated.

  17. Non-invasive detection of fasting blood glucose level via electrochemical measurement of saliva.

    Science.gov (United States)

    Malik, Sarul; Khadgawat, Rajesh; Anand, Sneh; Gupta, Shalini

    2016-01-01

    Machine learning techniques such as logistic regression (LR), support vector machine (SVM) and artificial neural network (ANN) were used to detect fasting blood glucose levels (FBGL) in a mixed population of healthy and diseased individuals in an Indian population. The occurrence of elevated FBGL was estimated in a non-invasive manner from the status of an individual's salivary electrochemical parameters such as pH, redox potential, conductivity and concentration of sodium, potassium and calcium ions. The samples were obtained from 175 randomly selected volunteers comprising half healthy and half diabetic patients. The models were trained using 70 % of the total data, and tested upon the remaining set. For each algorithm, data points were cross-validated by randomly shuffling them three times prior to implementing the model. The performance of the machine learning technique was reported in terms of four statistically significant parameters-accuracy, precision, sensitivity and F1 score. SVM using RBF kernel showed the best performance for classifying high FBGLs with approximately 85 % accuracy, 84 % precision, 85 % sensitivity and 85 % F1 score. This study has been approved by the ethical committee of All India Institute of Medical Sciences, New Delhi, India with the reference number: IEC/NP-278/01-08-2014, RP-29/2014. PMID:27350930

  18. Glucose intolerance in dairy goats with pregnancy toxemia: Lack of correlation between blood pH and beta hydroxybutyric acid values.

    Science.gov (United States)

    Lima, Miguel S; Cota, João B; Vaz, Yolanda M; Ajuda, Inês G; Pascoal, Rita A; Carolino, Nuno; Hjerpe, Charles A

    2016-06-01

    This study assessed the response to a glucose tolerance test in dairy goats with pregnancy toxemia (PT), in healthy, pregnant, non-lactating dairy goats in the last month of gestation (HP), and in healthy, lactating, non-pregnant, dairy goats in mid-lactation (HL). A 500 mL volume of a 5% glucose solution was administered by the IV route. Blood glucose concentrations returned to pre-infusion levels by 90 min in all 8 HL goats, and by 180 min in all 8 HP goats. In contrast, concentrations of blood glucose were still significantly above pre-infusion levels at 180 min post-infusion in all 8 PT goats. Thus, marked glucose intolerance was demonstrated in the PT goats, and mild intolerance was noted in the HP goats. In 25 goats diagnosed with PT and having blood beta hydroxybutyric acid (BHBA) values ≥ 2.9 mmol/L, the correlation coefficient for BHBA with blood pH was non-significant. PMID:27247464

  19. Effects of long duration exercise on cognitive function, blood glucose, and counterregulatory hormones in male cyclists.

    Science.gov (United States)

    Grego, Fabien; Vallier, Jean-Marc; Collardeau, Maya; Bermon, Stéphane; Ferrari, Patricia; Candito, Mirande; Bayer, Pascale; Magnié, Marie-Noëlle; Brisswalter, Jeanick

    2004-07-01

    Electrocortical effects of long duration exercise on cognitive function were investigated by analyzing P300 amplitude and latency changes during a 3-h cycling exercise. P300 components were measured in 12 well-trained cyclists and blood glucose, cortisol, insulin, glycerol, and free fatty acids (FFAs) epinephrine and norepinephrine were analyzed. Results indicated that P300 components were affected by exercise with a temporary increase in amplitude between the 1st and the 2nd hour and an increase in latency after 2 h of exercise concomitant with some hormonal changes, including an increase in cortisol and epinephrine and a decrease in blood glucose. These findings suggest a combined effect of arousal and central fatigue on electrocortical indices of cognitive function during acute physical exercise. PMID:15196681

  20. Scale Space Methods for Analysis of Type 2 Diabetes Patients' Blood Glucose Values

    Directory of Open Access Journals (Sweden)

    Stein Olav Skrøvseth

    2011-01-01

    Full Text Available We describe how scale space methods can be used for quantitative analysis of blood glucose concentrations from type 2 diabetes patients. Blood glucose values were recorded voluntarily by the patients over one full year as part of a self-management process, where the time and frequency of the recordings are decided by the patients. This makes a unique dataset in its extent, though with a large variation in reliability of the recordings. Scale space and frequency space techniques are suited to reveal important features of unevenly sampled data, and useful for identifying medically relevant features for use both by patients as part of their self-management process, and provide useful information for physicians.

  1. Scale space methods for analysis of type 2 diabetes patients' blood glucose values.

    Science.gov (United States)

    Skrøvseth, Stein Olav; Godtliebsen, Fred

    2011-01-01

    We describe how scale space methods can be used for quantitative analysis of blood glucose concentrations from type 2 diabetes patients. Blood glucose values were recorded voluntarily by the patients over one full year as part of a self-management process, where the time and frequency of the recordings are decided by the patients. This makes a unique dataset in its extent, though with a large variation in reliability of the recordings. Scale space and frequency space techniques are suited to reveal important features of unevenly sampled data, and useful for identifying medically relevant features for use both by patients as part of their self-management process, and provide useful information for physicians. PMID:21436873

  2. POCT血糖仪、生化仪葡萄糖氧化酶法和己糖激酶法检测新生儿血糖的研究%Study on Neonatal Blood Glucose Detected by POCT Glucose Meters and Biochemical Analyzer with Glucose Oxidase Method and Hexokinase Assay

    Institute of Scientific and Technical Information of China (English)

    李小斌; 杨阳; 张士朋; 贺菊晖; 郭威

    2012-01-01

    blood was collected from adult patients with hyperglycemia, normal blood glucose and hypoglycemia, 30 cases for each group and three portions for each sample of each patient. The glucose of the first potions (Group A) was detected by 8 blood glucose meters of 6 brands. The blood of the second potions (Group B) were processed to simulate neonate blood detection, that is, after centrifugation, part of the plasma was absorbed and the hematocrit was adjusted to 60%, and then the blood glucose was measured by the 8 blood glucose meters. The glucose of the third potions was measured by biochemical analyzer with hexokinase assay. In the glucose detection of neonatal blood, the glucose of capillary blood from 40 neonates with normal total bilirubin and 20 cases with elevated total bilirubin was detected by Johnson & Johnson ONE Touch Sure Step Glucose Meter, and at the same time, the glucose of their venous blood was measured by biochemical analyzer with glucose oxidase method and hexokinase assay. Results In the detection of glucose of simulated neonatal blood, glucose detected by Johnson & Johnson ONE Touch Sure Step and by Roche ACCU - CHEK Active (machine injection) with glucose oxidase enzyme photochemical method did not show any significant difference for blood from patients with hyperglycemia, normal blood glucose and hypoglycemia in the Group A (normal hematocrit) and the Group B (high hematocrit) (P>0.05), and the detection results had a good correlation with the results by biochemical analyzer with hexokinase method (r > 0.95). In the detection of neonatal blood, the test results by Johnson & Johnson ONE Touch Sure Step and by biochemical analyzer with glucose oxidase method and hexokinase assay did not indicate significant difference (P>0.05). Conclusions Concerning the capacity of the POCT glucose meters against the influence of high hematocrit, glucose oxidase photochemical method is better than the glucose oxidase electrode method and glucose dehydrogenase

  3. Effect of fenugreek, onion and garlic on blood glucose and histopathology of pancreas of alloxan-induced diabetic rats

    Directory of Open Access Journals (Sweden)

    Jelodar Gholamali

    2005-02-01

    Full Text Available BACKGROUND: Many traditional treatments have been recommended in the alternative system of medicine for treatment of diabetes mellitus; however, the mechanism of most of the herbals used has not been defined. AIMS: This study was carried out to clarify the effect of fenugreek, garlic and onion, recommended in Persian folklore medicine as beneficial in the treatment of diabetes, on blood glucose and their possible effect on pancreatic tissue. METHODS AND MATERIAL: Diabetes mellitus was induced in 20 out of 25 adult male albino rats, using intraperitoneal injection of 185 mg/kg BW alloxan. The diabetic rats were divided into four groups, three of which were fed a diet containing 12.5% BW Allium sativum (garlic, Allium cepa (onion or Trigonella foenum-graecum (fenugreek for 15 days. The fourth group (positive control received an ordinary diet. The remaining non-diabetic rats (negative control group received neither alloxan nor the mentioned plants. Following consumption of plants, blood glucose was measured every day and on the last day the pancreas were removed and stained with H&E and Gomeri aldehyde fuchsin (GAF. Morphology of the pancreatic sections and the following morphometric factors were studied: volume density of B cells, volume density of islets, percent of B cells, number of islets per square millimeter, average area of islets and average volume density of B cell in whole pancreas. STATISTICAL ANALYSIS USED: One-way Analysis of Variance (ANOVA test and Duncan′s multiple range tests were used to evaluate the data. RESULTS AND CONCLUSION: The results of this study indicate that only garlic was able to reduce blood glucose significantly compared with the control group (P<0.05. In the control positive group all the mentioned morphometric factors were significantly changed in comparison with the control negative (normal health group, but the same did not show significant change between treated and untreated diabetics.

  4. Need for testing glucose tolerance in the early weeks of pregnancy

    Directory of Open Access Journals (Sweden)

    Seshiah Veeraswamy

    2016-01-01

    Full Text Available Aims: This observational study aims to determine the frequency of occurrence of glucose intolerance in the early weeks of pregnancy. Materials and Methods: New World Health Organization 2013 guidelines recommends “A Single Step Procedure”(SSP as an option for diagnosing gestational diabetes mellitus (GDM. Pregnant women attending 131 prenatal clinics across India for the first time underwent SSP consisting of administration of 75 goral glucose irrespective of the last meal timing and to diagnose GDM with 2 h plasma glucose (PG value≥7.8 mmol/L (7.8 mmol/L. Results: In a cohort of n = 11,785, the number of pregnant women who underwent the test in first, second, and third trimesters were 4300, 4632, and 2853, respectively. Documented blood glucose values were available for 9282 pregnant women and in them, diagnosis of GDM was made in 740 (8%. Among them, 233 (31.5%, 320 (43.2%, and 187 (25.3% were in the first, second and third trimesters, respectively. Positive family history of diabetes (43% and history of fetal loss in previous pregnancy (27% was more common in women diagnosed with GDM in the first trimester compared to GDM diagnosed in the second or third trimester. Conclusion: Manifestation of GDM in the early weeks of gestation is quite common.

  5. What is the optimal blood glucose target in critically ill patients? A nested cohort study

    OpenAIRE

    Ashraf Al-Tarifi; Nabil Abou-Shala; Tamim, Hani M; Rishu, Asgar H.; Yaseen M. Arabi

    2011-01-01

    Aims: There is an uncertainty about what constitutes an optimal level of blood glucose (BG) in critically ill patients. The objective of this study is to identify the optimal BG target for glycemic control in critically ill patients that is associated with survival benefit with the least hypoglycemia risk. Setting and Design: This is a nested cohort study within a randomized control trial conducted in a tertiary care center in King Abdulaziz Medical City, Riyadh, Kingdom of Saudi Arabia. ...

  6. Aging, Vascular Risk and Cognition: Blood Glucose, Pulse Pressure, and Cognitive Performance in Healthy Adults

    OpenAIRE

    Dahle, Cheryl L.; Jacobs, Bradley S.; Raz, Naftali

    2009-01-01

    Advanced age is associated with decline in many areas of cognition as well as increased frequency of vascular disease. Well-described risk factors for vascular disease such as diabetes and arterial hypertension have been linked to cognitive deficits beyond those associated with aging. To examine whether vascular health indices such as fasting blood glucose levels and arterial pulse pressure can predict subtle deficits in age-sensitive abilities, we studied 104 healthy adults (age 18 to 78 yea...

  7. Effect of Jiang Zhuo Mixture on Blood Glucose Level and Insulin Resistance in Diabetes

    Institute of Scientific and Technical Information of China (English)

    Chen Xiabo; Wang Hui

    2005-01-01

    @@ Based on the knowledge of diabetes in traditional Chinese medicine and modem biomedical sciences,Dr. Wang Hui (王晖) designed Jiang Zhuo Mixture (降浊合剂) , a preparation for treatment of fat diabetes type 2. Jiang Zhuo Mixture showed good actions of strengthening the spleen and stomach,separating the clear from the turbid, resolving the stasis and decreasing the blood glucose level. These were reported as follows.

  8. Dioscorea alata L. Reduces Body Weight by Reducing Food Intake and Fasting Blood Glucose Level

    OpenAIRE

    Helen, Olubobokun Titilope; Olusola, Aluko Esther; Eghosa E, Iyare; Bond, Anyaehie Ugochukwu

    2013-01-01

    Aims: The prevalence of type 2 diabetes may be most likely linked to obesity and its prevalence appears to have increased as the prevalence of obesity increased. Dioscorea alata L. has been observed to possess flavonoids which induce antidiabetic effect and phenolic compounds which could help in weight management. It has been postulated that any therapeutic regimes that can limit weight gain while simultaneously controlling blood glucose levels will be effective in managing diabetes. This stu...

  9. Blood Flow and Glucose Metabolism in Stage IV Breast Cancer: Heterogeneity of Response During Chemotherapy

    OpenAIRE

    Krak, Nanda; Hoeven, John; Hoekstra, Otto; Twisk, Jos; Wall, Ernst; Lammertsma, A. A.

    2008-01-01

    textabstractObjective: The purpose of the study was to compare early changes in blood flow (BF) and glucose metabolism (MRglu) in metastatic breast cancer lesions of patients treated with chemotherapy. Methods: Eleven women with stage IV cancer and lesions in breast, lymph nodes, liver, and bone were scanned before treatment and after the first course of chemotherapy. BF, distribution volume of water (Vd), MRglu/BF ratio, MRgluand its corresponding rate constants K1and k3were compared per tum...

  10. Impact of admission blood glucose level on outcomes in community-acquired pneumonia in older adults

    OpenAIRE

    Bhattacharya RK; Mahnken JD; Rigler SK

    2013-01-01

    Rajib K Bhattacharya, Jonathan D Mahnken, Sally K RiglerUniversity of Kansas School of Medicine, Kansas City, KS, USABackground: Community-acquired pneumonia (CAP) is a common cause of morbidity and mortality in older adults. Although diabetes mellitus is a risk factor for pneumonia, the clinical impact of blood glucose level at the time of admission is not clear. Our goal was to examine the association between admission hyperglycemia and subsequent mortality, length of stay, and readmission ...

  11. Blood glucose may be an alternative to cholesterol in CVD risk prediction charts

    OpenAIRE

    Braun, Julia; Bopp, Matthias; Faeh, David

    2013-01-01

    Background Established risk models for the prediction of cardiovascular disease (CVD) include blood pressure, smoking and cholesterol parameters. The use of total cholesterol for CVD risk prediction has been questioned, particularly for primary prevention. We evaluated whether glucose could be used instead of total cholesterol for prediction of fatal CVD using data with long follow-up. Methods We followed-up 6,095 men and women aged ≥16 years who participated 1977-79 in a community based heal...

  12. Non-invasive detection of fasting blood glucose level via electrochemical measurement of saliva

    OpenAIRE

    Malik, Sarul; Khadgawat, Rajesh; Anand, Sneh; Gupta, Shalini

    2016-01-01

    Machine learning techniques such as logistic regression (LR), support vector machine (SVM) and artificial neural network (ANN) were used to detect fasting blood glucose levels (FBGL) in a mixed population of healthy and diseased individuals in an Indian population. The occurrence of elevated FBGL was estimated in a non-invasive manner from the status of an individual’s salivary electrochemical parameters such as pH, redox potential, conductivity and concentration of sodium, potassium and calc...

  13. Effects of Yogic Exercises on Life Stress and Blood Glucose Levels in Nursing Students

    OpenAIRE

    Kim, Sang Dol

    2014-01-01

    [Purpose] This study was performed to investigate the effects of yogic exercises on life stress and blood glucose levels in nursing students. [Subjects and Methods] The study was a randomized controlled trial. Twenty-seven undergraduate nursing students were randomly selected, with 12 assigned to an exercise group and 15 assigned to a control group. The yogic exercises intervention was undertaken for 60 minutes one day a week for 12 weeks. It consisted of physical exercise (surya namaskara) c...

  14. Blood glucose regulation in diabetics. A flatness based nonlinear control simulation study

    Science.gov (United States)

    Cocha, Guillermo; Podestá, Melina; Mazzadi, Alejandro; Amorena, Carlos; D’Atellis, Carlos

    2016-04-01

    Flat systems are a generalization of linear systems, but the techniques used for controlling flat systems are much different than many of the existing techniques for linear systems. In this paper we present the flatness-based control of blood glucose regulation in human system. A non-near model, he Bergman Minimal Model, is used o represent he dynamics of blood regulation in humans and because of the flatness property, he system variables can be expressed as functions of he at output and heir time derivatives and a control aw developed.

  15. Effects of breakfast with different calorigenic amounts on blood glucose, insulin and glucagon levels

    Institute of Scientific and Technical Information of China (English)

    黄素霞; 傅运兴; 王慧铭; GIANGSylvia

    2003-01-01

    This study was aimed to investigate the relationship between breakfast and serum glucose, insulin and glueagon concentrations in order to establish a model breakfast appropriate for Chinese. Twenty-four vol-unteers were randomly assigned to four study groups: high carbohydrate breakfast, high fat and protein break-fast, the typical breakfast and fasting. Each subject had serum and urine samples collected while fasting andat 1,2 and 3.5 hours following the meal. The concentration of serum glucose, insulin and glucagon was mea-sured. The levels of serum glucose in group A, B and C differed significantly at 1 and 2 hour after meal com-pared to those at fasting ( P < 0.05) . The serum glucose in group A increased insignificantly after meal. The serum insulin levels were in group A, B and C significant different compared with control group( P < 0.05) .Those peaked at 1 hour after meal ,with group C rising the furthest. Compared with the fasting group, the se-rum glueagons rose and maintained the increase after breakfast in group A, B and C (P < 0.05).The data suggested that various diets with different ealorigenie amounts increased hormone concentration to various extents. We found that a breakfast rich in carbohydrates could maintain proper blood glucose level.

  16. Effects of breakfast with different calorigenic amounts on blood glucose, insulin and glucagon levels

    Institute of Scientific and Technical Information of China (English)

    HUANG Su-xia(黄素霞); FU Yun-xing(傅运兴); WANG Hui-ming(王慧铭); GIANG Sylvia

    2003-01-01

    This study was aimed to investigate the relationship between breakfast and serum glucose, insulin and glucagon concentrations in order to establish a model breakfast appropriate for Chinese. Twenty-four volunteers were randomly assigned to four study groups: high carbohydrate breakfast, high fat and protein breakfast, the typical breakfast and fasting. Each subject had serum and urine samples collected while fasting and at 1,2 and 3.5 hours following the meal. The concentration of serum glucose, insulin and glucagon was measured. The levels of serum glucose in group A,B and C differed significantly at 1 and 2 hour after meal compared to those at fasting (P<0.05). The serum glucose in group A increased insignificantly after meal. The serum insulin levels were in group A,B and C significant different compared with control group(P<0.05).Those peaked at 1 hour after meal ,with group C rising the furthest. Compared with the fasting group, the serum glucagons rose and maintained the increase after breakfast in group A,B and C (P<0.05).The data suggested that various diets with different calorigenic amounts increased hormone concentration to various extents. We found that a breakfast rich in carbohydrates could maintain proper blood glucose level.

  17. Comparison of performance for four types of POCT blood glucose meters%4种POCT血糖仪的性能比较

    Institute of Scientific and Technical Information of China (English)

    陈芳华; 饶万楷

    2011-01-01

    Objective: To evaluate the main performance for four types of POCT blood glucose meters. Methods: Fresh heparinized blood samples with high, medium, low glucose concentration were detected by four types of POCT blood glucose meters (Johnson & Johnson,Roche, Abbott, and Reiter). The degree of precision, the rate of recovery, linearity, intederence, and hematocrit effect for the four types of blood glucose meters were evaluated. The results of venous blood glucose determined by biochemical analyzer and the results of venous blood, finger blood of blood glucose meter were compared. Results: Degree of precision for four detecting systems meets the requirement (CV<10%); all the rates of recovery are in the scope of 90%~110%. The linearity of Roche blood glucose meter is the best of all with high ability of anti-hemoglobin effect, but influenced greatly by aacorbie acid. Hematocrit has less impact on Roche blood glucose meters,while in the other three types of blood glucose meters, it is significantly reduced with the increase of hematocrit reading. The measured results of Johnson & Johnson, Roche, Abbott blood glucose meter are affected by galactose and xylose respectively. The results of other three types of hloed glucose meters are higher than the result of biochemical analyzer (P<O.05) except for Reiter blood glucose meters. Results of finger blood glucose determination by Abbott blood glucose meters are higher than the result of venous blood glucose determination by biochemical analyzer (P<O.05), but no difference was found with other three types of meters. Bilimbin, triglycerides, fructose, maltose, sucrose have no significant effect on the result of blood glucose as tested by four kinds of blood glucose meters.Conclusion: Them are limitations for detection performance of four types POCT glucose meters. Sufficient attention should be paid in clinical monitoring of blood glucose levels for patients. Thus fully understand their characteristics in order

  18. Effect of Iranian Honey bee (Apis Mellifera Venom on Blood Glucose and Insulin in Diabetic Rats

    Directory of Open Access Journals (Sweden)

    Seyyedeh Mahbubeh Mousavi

    2012-12-01

    Full Text Available Background: Diabetes is an important disease. This disease is a metabolic disorder characterized by hyperglycemia resulting from perturbation in insulin secretion, insulin action or both. Honey bee venom contains a wide range of polypeptide agents. The principle components of bee venom are mellitin and phospholipase A2. These components increase insulin secretion from the β-cells of pancreas. This study was conducted to show the hypoglycemic effect of honey bee venom on alloxan induced diabetic male rats.Methods: Eighteen adult male rats weighting 200±20 g were placed into 3 randomly groups: control, alloxan monohy­drate-induced diabetic rat and treated group that received honey bee venom daily before their nutrition for four months. Forty eight hours after the last injection, blood was collected from their heart, serum was dissented and blood glucose, insulin, triglyceride and total cholesterol were determined.Results: Glucose serum, triglyceride and total cholesterol level in treated group in comparison with diabetic group was significantly decreased (P< 0.01. On the other hand, using bee venom causes increase in insulin serum in com­parison with diabetic group (P< 0.05.Conclusion: Honeybee venom (apitoxin can be used as therapeutic option to lower blood glucose and lipids in dia­betic rats.

  19. System Accuracy Evaluation of the GlucoRx Nexus Voice TD-4280 Blood Glucose Monitoring System

    Directory of Open Access Journals (Sweden)

    Muhammad Khan

    2014-01-01

    Full Text Available Use of blood glucose (BG meters in the self-monitoring of blood glucose (SMBG significantly lowers the risk of diabetic complications. With several BG meters now commercially available, the International Organization for Standardization (ISO ensures that each BG meter conforms to a set degree of accuracy. Although adherence to ISO guidelines is a prerequisite for commercialization in Europe, several BG meters claim to meet the ISO guidelines yet fail to do so on internal validation. We conducted a study to determine whether the accuracy of the GlucoRx Nexus TD-4280 meter, utilized by our department for its cost-effectiveness, complied with ISO guidelines. 105 patients requiring laboratory blood glucose analysis were randomly selected and reference measurements were determined by the UniCel DxC 800 clinical system. Overall the BG meter failed to adhere to the ≥95% accuracy criterion required by both the 15197:2003 (overall accuracy 92.4% and 15197:2013 protocol (overall accuracy 86.7%. Inaccurate meters have an inherent risk of over- and/or underestimating the true BG concentration, thereby risking patients to incorrect therapeutic interventions. Our study demonstrates the importance of internally validating the accuracy of BG meters to ensure that its accuracy is accepted by standardized guidelines.

  20. 21 CFR 864.6550 - Occult blood test.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Occult blood test. 864.6550 Section 864.6550 Food... DEVICES HEMATOLOGY AND PATHOLOGY DEVICES Manual Hematology Devices § 864.6550 Occult blood test. (a) Identification. An occult blood test is a device used to detect occult blood in urine or feces. (Occult blood...

  1. 21 CFR 640.14 - Testing the blood.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 7 2010-04-01 2010-04-01 false Testing the blood. 640.14 Section 640.14 Food and... ADDITIONAL STANDARDS FOR HUMAN BLOOD AND BLOOD PRODUCTS Red Blood Cells § 640.14 Testing the blood. Blood from which Red Blood Cells are prepared shall be tested as prescribed in § 610.40 of this chapter...

  2. The Acute Impact of Ingestion of Sourdough and Whole-Grain Breads on Blood Glucose, Insulin, and Incretins in Overweight and Obese Men

    Directory of Open Access Journals (Sweden)

    Anita Mofidi

    2012-01-01

    Full Text Available Consumption of whole-grain and sourdough breads is associated with improved glucose homeostasis. We examined the impact of commercial breads on biomarkers of glucose homeostasis in subjects at risk for glucose intolerance. In a randomized, crossover study, overweight or obese males ingested 11-grain, sprouted-grain, 12-grain, sourdough, or white bread on different occasions, matched for available carbohydrate (50 g in part 1 (n=12 and bread mass (107 g in part 2 (n=11, and blood glucose, insulin and glucose-dependent insulinotropic polypeptide (GIP and glucagon-like peptide-1 (GLP-1 were determined for 3 h. In part 1, glucose response for sprouted-grain was lower than 11-grain, sourdough, and white breads. Insulin area under the curve (AUC for sourdough and white was lower than 11-grain and sprouted-grain breads. GLP-1 response to sourdough was lower than all breads. In part 2, glucose and insulin AUC for sourdough was greater than 11-grain, sprouted-grain, and 12-grain breads. Sprouted-grain bread improved glycemia by lowering glucose response and increasing GLP-1 response. In overweight and obese men, the glycemic response to sprouted grain bread was reduced in both parts 1 and 2 while the other whole-grain test breads did not improve metabolic responses in the acute postprandial state.

  3. The acute impact of ingestion of sourdough and whole-grain breads on blood glucose, insulin, and incretins in overweight and obese men.

    Science.gov (United States)

    Mofidi, Anita; Ferraro, Zachary M; Stewart, Katherine A; Tulk, Hilary M F; Robinson, Lindsay E; Duncan, Alison M; Graham, Terry E

    2012-01-01

    Consumption of whole-grain and sourdough breads is associated with improved glucose homeostasis. We examined the impact of commercial breads on biomarkers of glucose homeostasis in subjects at risk for glucose intolerance. In a randomized, crossover study, overweight or obese males ingested 11-grain, sprouted-grain, 12-grain, sourdough, or white bread on different occasions, matched for available carbohydrate (50 g) in part 1 (n = 12) and bread mass (107 g) in part 2 (n = 11), and blood glucose, insulin and glucose-dependent insulinotropic polypeptide (GIP) and glucagon-like peptide-1 (GLP-1) were determined for 3 h. In part 1, glucose response for sprouted-grain was lower than 11-grain, sourdough, and white breads. Insulin area under the curve (AUC) for sourdough and white was lower than 11-grain and sprouted-grain breads. GLP-1 response to sourdough was lower than all breads. In part 2, glucose and insulin AUC for sourdough was greater than 11-grain, sprouted-grain, and 12-grain breads. Sprouted-grain bread improved glycemia by lowering glucose response and increasing GLP-1 response. In overweight and obese men, the glycemic response to sprouted grain bread was reduced in both parts 1 and 2 while the other whole-grain test breads did not improve metabolic responses in the acute postprandial state.

  4. Interactive two-step training and management strategy for improvement of the quality of point-of-care testing by nurses:implementation of the strategy in blood glucose measurement

    OpenAIRE

    Lehto, L. (Liisa)

    2014-01-01

    Abstract Point-of-care testing (POCT) is defined as laboratory tests performed outside the traditional clinical laboratory close to the patient at the time and place where care is received, such as hospitals and healthcare centers. The main reason for the use of POCT is that they provide rapid results and enable prompt interventions, with hopefully improved patient outcomes. All phases of laboratory procedure are included in POCT offering many opportunities for errors, which can influence ...

  5. FDA Recommends All Blood Donations Be Tested for Zika

    Science.gov (United States)

    ... FDA Recommends All Blood Donations Be Tested for Zika Updated guidance provides further protection for U.S. blood ... entire blood supply be routinely screened for the Zika virus. In February, the FDA recommended testing of ...

  6. Salivary Glucose Concentration and Excretion in Normal and Diabetic Subjects

    Directory of Open Access Journals (Sweden)

    Cedric Jurysta

    2009-01-01

    saliva glucose concentration was comparable, however, to that of blood glucose concentration. The relationship between these two variables was also documented in normal subjects and diabetic patients undergoing an oral glucose tolerance test.

  7. Blood glucose may be an alternative to cholesterol in CVD risk prediction charts

    Science.gov (United States)

    2013-01-01

    Background Established risk models for the prediction of cardiovascular disease (CVD) include blood pressure, smoking and cholesterol parameters. The use of total cholesterol for CVD risk prediction has been questioned, particularly for primary prevention. We evaluated whether glucose could be used instead of total cholesterol for prediction of fatal CVD using data with long follow-up. Methods We followed-up 6,095 men and women aged ≥16 years who participated 1977-79 in a community based health study and were anonymously linked with the Swiss National Cohort until the end of 2008. During follow-up, 727 participants died of CVD. Based on the ESC SCORE methodology (Weibull regression), we used age, sex, blood pressure, smoking, and fasting glucose or total cholesterol. The mean Brier score (BS), area under the receiver-operating characteristic curve (AUC) and integrated discrimination improvement (IDI) were used for model comparison. We validated our models internally using cross-validation and externally using another data set. Results In our models, the p-value of total cholesterol was 0.046, that of glucose was p < 0.001. The model with glucose had a slightly better predictive capacity (BS: 2216x10-5 vs. 2232x10-5; AUC: 0.9181 vs. 0.9169, IDI: 0.009 with p-value 0.026) and could well discriminate the overall risk of persons with high and low concentrations. The external validation confirmed these findings. Conclusions Our study suggests that instead of total cholesterol glucose can be used in models predicting overall CVD mortality risk. PMID:23351551

  8. Impact of streptozotocin on altering normal glucose homeostasis during insulin testing in diabetic rats compared to normoglycemic rats

    Directory of Open Access Journals (Sweden)

    Qinna NA

    2015-05-01

    Full Text Available Nidal A Qinna,1 Adnan A Badwan2 1Department of Pharmacology and Biomedical Sciences, Faculty of Pharmacy and Medical Sciences, University of Petra, 2Research and Innovation Centre, The Jordanian Pharmaceutical Manufacturing Co. Plc. (JPM, Amman, Jordan Abstract: Streptozotocin (STZ is currently the most used diabetogenic agent in testing insulin and new antidiabetic drugs in animals. Due to the toxic and disruptive nature of STZ on organs, apart from pancreas, involved in preserving the body’s normal glucose homeostasis, this study aims to reassess the action of STZ in inducing different glucose response states in diabetic rats while testing insulin. Diabetic Sprague-Dawley rats induced with STZ were classified according to their initial blood glucose levels into stages. The effect of randomizing rats in such a manner was investigated for the severity of interrupting normal liver, pancreas, and kidney functions. Pharmacokinetic and pharmacodynamic actions of subcutaneously injected insulin in diabetic and nondiabetic rats were compared. Interruption of glucose homeostasis by STZ was challenged by single and repeated administrations of injected insulin and oral glucose to diabetic rats. In diabetic rats with high glucose (451–750 mg/dL, noticeable changes were seen in the liver and kidney functions compared to rats with lower basal glucose levels. Increased serum levels of recombinant human insulin were clearly indicated by a significant increase in the calculated maximum serum concentration and area under the concentration–time curve. Reversion of serum glucose levels to normal levels pre- and postinsulin and oral glucose administrations to STZ diabetic rats were found to be variable. In conclusion, diabetic animals were more responsive to insulin than nondiabetic animals. STZ was capable of inducing different levels of normal glucose homeostasis disruption in rats. Both pharmacokinetic and pharmacodynamic actions of insulin were

  9. The Effect of Ethanolic Extract of Urtica dioica Leaves on High Levels of Blood Glucose and Gene Expression of Glucose Transporter 2 (Glut2) in Liver of Alloxan-Induced Diabetic Mice

    OpenAIRE

    Ahmadi,, Kourosh R.; Awliaei; Haidarizadeh; Rostamzadeh

    2015-01-01

    Background Urtica dioica L. (stinging nettle) has been accepted for decreasing blood glucose levels; however, the exact mechanism of its anti-hyperglycemic effect remains to be understood. Objectives We aimed to examine the effects of ethanolic extract of stinging nettle leaves on blood glucose levels and gene expression of Glucose Transporter 2 (Glut2) in liver of alloxan-induced diabetic mice. ...

  10. The Effect of Abelmoschus Esculentus on Blood Levels of Glucose in Diabetes Mellitus

    Science.gov (United States)

    Khosrozadeh, Maryam; Heydari, Naval; Abootalebi, Malihe

    2016-01-01

    Background: Diabetes mellitus is a metabolic disorder that results in hyperglycemia. According to the statistics of the International Diabetes Federation (IDF), this problem has a fast growing prevalence and, unfortunately, leaves permanent complications on different body systems. For this reasons, nowadays attentions has been paid to the traditional medicine such as Okra (Abelmoscus esculentus). The aim of this study was the evaluation of the effect of Okra (Abelmoscus esculentus) on blood levels of glucose in diabetes. Methods: This is a review article, which was obtained by a search in databases such as PubMed, Google Scholar, and Magiran by using keywords such as diabetes, Okra, and hypoglycemic effect. Results: Various studies on Okra (Abelmoscus esculentus) showed that Abelmoscus esculentus (AE)/Okra extract has a hypoglycemic effect that helps decrease blood glucose level. Its properties can be a useful remedy to manage diabetes mellitus. In addition, it leads to inhibition of cholesterol absorption and subsequently decreases the level of lipid and fat in the blood. The results of an investigation on diabetic mice by using this material has shown the same effect and confirmed this conclusion. Conclusion: Based on the positive effects of Okra on reducing blood sugar level, the widespread use of this plant is recommended. Clearly, further research is required.

  11. Effect of glucose on photoacoustic signals at the wavelengths of 1064 and 532 nm in pig blood and intralipid

    International Nuclear Information System (INIS)

    Non-invasive glucose monitoring is one of the most active areas in biomedical research. Various techniques have been developed over the years to meet the clinical requirements of non-invasive monitoring in the physiologically relevant glucose concentration range, but without a breakthrough. This paper used the pulsed photoacoustic (PA) technique to study glucose-induced changes in pig whole blood and 1% IntralipidTM using an Nd : YAG laser with wavelengths of 1064 and 532 nm as the optical energy source. Scattering properties of the sample significantly affect the laser-induced pressure waves. Glucose was found to affect both the scattering and the absorption properties of the samples. The results showed an increase of 11.4%/500 mg dl-1 added glucose in the peak-to-peak value of the PA signal in blood at 1064 nm, whereas the corresponding increase was only 1.35%/500 mg dl-1 in 1% IntralipidTM. At a wavelength of 532 nm, the glucose increased the peak-to-peak value of the PA signal by 6.0%/500 mg dl-1 added glucose in blood. On the whole, the pulsed PA technique proved to be an efficient tool for the study of glucose-induced changes in blood and tissue phantoms in vitro

  12. A Comparative Study of Blood Glucose Measurements Using Glucometer Readings and the Standard Method in the Diagnosis of Neonatal Hypoglycemia

    Directory of Open Access Journals (Sweden)

    Mohammad Torkaman

    2016-03-01

    Full Text Available Background: Hypoglycemia is one of the most common neonatal disorders, associated with severe complications. There has been a great deal of controversy regarding the definition and screening of hypoglycemia. Therefore, in this study, we aimed to determine a cut-off value for blood glucose level in glucometer readings. Methods: This cross-sectional study was conducted on 238 newborns at risk of hypoglycemia, admitted to Baqiyatallah Hospital of Tehran, Iran in 2012; the subjects were selected via simple sampling. After obtaining informed consents from the newborns’ parents, 1 cc blood samples were sent to the laboratory for measuring the blood glucose level. Moreover, venous blood samples, as well as heel-stick blood samples, were obtained for glucometer measurements. Blood glucose measurements were used to determine the cut-off value by the receiver operating characteristic (ROC curve and make comparisons with the diagnostic criteria for hypoglycemia in the literature. Results: A total of 238 infants with the mean weight of 2869±821.9 g were enrolled in this study. The mean (±SD blood glucose levels were 65.1±22.9, 82.9±24.7, and 84.4±24.8 mg/dl, based on the standard laboratory method, glucometer reading of venous blood samples, and glucometer reading of heel-stick capillary blood samples, respectively. The optimal cut-off point for hypoglycemia was determined as 65 mg/dl, using glucometer-based assessment of heel-stick blood samples. Conclusion: The significant difference in blood glucose levels measured by the laboratory method and outpatient glucometer readings highlights the importance of a cut-off value for rapid assessment and control of blood glucose and timely detection of hypoglycemia. In fact, the cut-off value introduced in the present study could facilitate such measurements.

  13. Analysis of Blood Glucose in Patients With Gestational Diabetes Mellitus%妊娠糖尿病患者的血糖检验分析

    Institute of Scientific and Technical Information of China (English)

    李国伟

    2015-01-01

    目的:探究妊娠糖尿病患者进行血糖检验的应用和分析。方法选取2014年1月~2015年3月在我院进行血糖检验的53例妊娠糖尿病患者作为实验组,并选择53例同期进行血糖检验的健康妊娠者作为对照组,对血糖检验情况进行分析对比。结果健康妊娠者的血糖都在正常范围内,实验组患者的血糖值高于正常值,差异有统计学意义(P<0.05)。结论孕产妇定期检验血糖,并及时发现以及干预,使其血糖保持在正常范围内,可以减少胎儿和产妇的不良症状,对妊娠糖尿病患者给予定期的血糖检测具有较高的临床意义。%Objective To explore the application and analysis of blood glucose test in patients with gestational diabetes mellitus. Methods 53 cases of gestational diabetes mellitus were selected as the experimental group in January 2014 to March 2015 in our hospital, and 53 cases of the same period of blood glucose test of a healthy pregnancy as the control group, the test of blood glucose were compared. Results The blood glucose of healthy pregnant patients was normal, and the blood glucose level of the experimental group was higher than that of normal value, and the difference was statistically significant (P<0.05). Conclusion Maternal periodic inspection of blood sugar, and timely discovery and intervention, the levels of blood glucose in the normal range, can reduce the fetal and maternal adverse symptoms and so on gestational diabetes mellitus patients given regular blood sugar testing has high clinical signiifcance.

  14. Analysis Article on the Performance Analysis of the OneTouch® UltraVue™ Blood Glucose Monitoring System

    OpenAIRE

    Solnica, Bogdan

    2009-01-01

    In this issue of Journal of Diabetes Science and Technology, Chang and colleagues present the analytical performance evaluation of the OneTouch® UltraVue™ blood glucose meter. This device is an advanced construction with a color display, used-strip ejector, no-button interface, and short assay time. Accuracy studies were performed using a YSI 2300 analyzer, considered the reference. Altogether, 349 pairs of results covering a wide range of blood glucose concentrations were analyzed. Patients ...

  15. Effects of exposure to electromagnetic field radiation (EMFR) generated by activated mobile phones on fasting blood glucose

    OpenAIRE

    Sultan Ayoub Meo; Khalid Al Rubeaan

    2013-01-01

    Objective: Extensive use of mobile phones has been accompanied by a common public debate about possible adverse effects on human health. No study has been published so far to establish any association between the fastest growing innovation of mobile phone and fasting blood glucose. The aim was to determine the effects of exposure to electromagnetic field radiation generated by mobile phones on fasting blood glucose in Wistar Albino rats. Materials and Methods: 40 Male Albino rats (Wistar Stra...

  16. Effects of Mad Honey on Blood Glucose and Lipid Levels in Rats With Streptozocin-Induced Diabetes

    OpenAIRE

    ÖZTAŞAN, Nuray

    2005-01-01

    This study investigated whether mad honey affects blood glucose and lipid levels in experimental animals. It was found that mad honey caused significant decreases in blood glucose and lipid levels in animals with streptozocin-induced diabetes mellitus (n = 10) and controls (n = 10). These decreases may be due to grayanotoxins in the mad honey causing the islets of Langerhans in the pancreas to secrete insulin by stimulating the parasympathetic nervous system or M2-muscarinic receptors.

  17. Effect of whey on blood glucose and insulin responses to composite breakfast and lunch meals in type 2 diabetic subjects

    DEFF Research Database (Denmark)

    Frid, Anders H; Nilsson, Mikael; Holst, Jens Juul;

    2005-01-01

    glycemic index (GI) with whey proteins may increase insulin secretion and improve blood glucose control in type 2 diabetic subjects. DESIGN: Fourteen diet-treated subjects with type 2 diabetes were served a high-GI breakfast (white bread) and subsequent high-GI lunch (mashed potatoes with meatballs...... insulin release and reduces postprandial blood glucose excursion after a lunch meal consisting of mashed potatoes and meatballs in type 2 diabetic subjects....

  18. 21 CFR 640.33 - Testing the blood.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 7 2010-04-01 2010-04-01 false Testing the blood. 640.33 Section 640.33 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) BIOLOGICS ADDITIONAL STANDARDS FOR HUMAN BLOOD AND BLOOD PRODUCTS Plasma § 640.33 Testing the blood. (a) Blood...

  19. Blood Glucose as a Predictor of Mortality in Children Admitted to the Hospital with Febrile Illness in Tanzania

    OpenAIRE

    Nadjm, Behzad; Mtove, George; Amos, Ben; Hildenwall, Helena; Najjuka, Anne; Mtei, Frank; Todd, Jim; Reyburn, Hugh

    2013-01-01

    Data from a prospective study of 3,319 children ages 2 months to 5 years admitted with febrile illness to a Tanzanian district hospital were analyzed to determine the relationship of blood glucose and mortality. Hypoglycemia (blood sugar < 2.5 mmol/L and < 45 mg/dL) was found in 105 of 3,319 (3.2%) children at admission, and low-normal blood glucose (2.5-5 mmol/L and 45-90 mg/dL) was found in 773 of 3,319 (23.3%) children. Mortality was inversely related to admission blood sugar; compared wit...

  20. Profile of blood glucose and ultrastucture of beta cells pancreatic islet in alloxan compound induced rats

    Directory of Open Access Journals (Sweden)

    I Nyoman Suarsana

    2010-06-01

    Full Text Available Diabetes is marked by elevated levels of blood glucose, and progressive changes of the structure of pancreatic islet histopathology. The objective of this research was to analyse the glucose level and histophatological feature in pancreatic islet in alloxan compound induced rats. A total of ten male Spraque Dawley rats of 2 months old were used in this study. The rats were divided into two groups: (1 negative control group (K-, and (2 positif induced alloxan group (diabetic group =DM. The rats were induced by a single dose intraperitonial injection of alloxan compound 120 mg/kg of body weight. The treatment was conducted for 28 days. Blood glucose levels of rats were analysed at 0, 4, 7, 14, 21, and 28 days following treatment. At the end of the experiment, rats were sacrificed by cervical dislocation. Pancreas was collected for analysis of histopathological study by Immunohistochemical technique, and ultrastructural study using transmission electron microscope (TEM. The result showed that Langerhans islet of diabetic rat (rat of DM group showed a marked reduction of size, number of Langerhans islet of diabetic rat decrease, and characterized by hyperglycemic condition. By using TEM, beta cells of DM group showed the rupture of mitochondrial membrane, the lost of cisternal structure of inner membrane of mitocondria, reduction of insulin secretory granules, linkage between cells acinar with free Langerhans islet, and the caryopicnotic of nucleus.

  1. Low blood glucose levels and other complications during growth hormone supplementation in sepsis

    Directory of Open Access Journals (Sweden)

    Faintuch Joel

    1999-01-01

    Full Text Available Blood glucose levels in the high normal range or even moderate hyperglycemia is the expected profile in septic postoperative patients receiving high-calorie enteral alimentation. The addition of growth hormone as an anabolic agent should additionally reinforce this tendency. In a cancer patient undergoing partial gastrectomy with lymphadenectomy and suffering from postoperative subphrenic abscess and prolonged sepsis, tube feeding (38.3 kcal/kg/day and growth hormone (0.17 IU/kg/day were simultaneously administered for 25 days. Blood glucose levels were in the lower limits of the normal range before growth hormone introduction, and continued with a similar tendency during most of the therapeutic period. Two additional complications, namely heart arrest and peripheral edema, were documented during the same period. It is concluded that sepsis was the most likely mechanism for low glucose values, and that high-calorie enteral diet and growth hormone supplementation did not prevent that result. It is uncertain whether heart arrest was due to the drug, but its association with peripheral edema is well documented in clinical series.

  2. Seventy-five gram glucose tolerance test to assess carbohydrate malabsorption and small bowel bacterial overgrowth

    Institute of Scientific and Technical Information of China (English)

    Yoshihisa Urita; Motonobu Sugimoto; Kazumasa Miki; Susumu Ishihara; Tatsuo Akimoto; Hiroto Kato; Noriko Hara; Yoshiko Honda; Yoko Nagai; Kazushige Nakanishi; Nagato Shimada

    2006-01-01

    AIM: To investigate non-invasively the incidence of absorption of carbohydrates in diabetic patients during an oral glucose tolerance test (OGTT) and to determine whether malabsorption may be associated with insulin secretion and insulin resistance.METHODS: A standard 75-g OGTT was performed in 82 diabetic patients. The patients received 75 g of anhydrous glucose in 225 mL of water after an overnight fasting and breath samples were collected at baseline and up to 120 min afler ingestion. Breath hydrogen and methane concentrations were measured. Blood glucose and serum insulin concentrations were measured before ingestion and at 30, 60, g0, 120 min post-ingestion.RESULTS: When carbohydrate malabsorption was defined as subjects with an increase of at least 10 ppm (parts per million) in hydrogen or methane excretion within a 2-h period, 28 (34%) had carbohydrate malabsorption. According to the result of increased breath test, 21 (75%) patients were classified as small bowel bacterial overgrowth and 7 (25%) as glucose malabsorption. Patients with carbohydrate malabsorption were older and had poor glycemic control as compared with those without carbohydrate malabsorption. The HOMA value, the sum of serum insulin during the test and the Ainsulin/Aglucose ratio were greater in patients with carbohydrate malabsorption.CONCLUSION: Insulin resistance may be overestimated by using these markers if the patient has carbohydrate malabsorption, or that carbohydrate malabsorption may be present prior to the development of insulin resistance.Hence carbohydrate malabsorption should be taken into account for estimating insulin resistance and β-cell function.

  3. Self-monitoring of blood glucose improved glycaemic control and 10-year coronary heart disease risk profile of type 2 diabetic patients

    Institute of Scientific and Technical Information of China (English)

    Ezenwaka Chidum; JonesLeCointe Altheia; Dimgba Agbai; Okali Fidelis; Skinner Teppany; Rodriguez Martina; Extavour Rian; Davis Verdine; Spencer Alida; Mayers Hasina

    2011-01-01

    Background The debate over the overall benefits of self-monitoring of blood glucose in type 2 diabetes patients is still continuing.We aimed to assess the difference in glycaemic control and coronary heart disease (CHD) risk levels of experimental type 2 diabetes patients provided with facilities for self-monitoring blood glucose and their counterparts without such facilities.Methods Sixty-one patients who had no prior experience in using glucometers were studied as intervention (n=30) and control (n=31) groups.The intervention group was trained in self-monitoring of blood glucose and documentation.Baseline blood glucose and fasting blood glucose were measured and the intervention patients were provided with glucometers and advised to self-monitor their fasting and postprandial blood glucose over six months.The 10-year CHD risk levels were determined with the United Kingdom Prospective Diabetes Study-derived risk engine calculator.Results The age and diabetes duration were similar in the two groups (P >0.05).The majority of the patients were unemployed or retired females with only a primary level education.After 3 months,the haemogolbin A1c (HbA1c) levels of the control patients remained unchanged ((7.8±0.3)% vs.(7.9±0.4)%,P >0.05) whereas the HbA1c levels of the intervention patients were significantly reduced from the baseline at three ((9.6±0.3)% vs.(7.8±0.3)%,P <0.001) and six ((9.2±0.4)% vs.(7.5±0.3)%,P <0.001) months.Interestingly,while the 10-year CHD risk level of the control group remained unchanged after three months,that of the intervention group was remarkably reduced at three and six months from the baseline level ((7.4±1.3)% vs.(4.5±0.9)%,P=0.056).Conclusion Self-monitoring of blood glucose in type 2 diabetes patients significantly improved glycaemic control and the CHD risk profile,suggesting that type 2 diabetes patients will potentially benefit from inclusion of glucose meters and testing strips in their health-care package.

  4. Diabetes Numeracy and Blood Glucose Control: Association With Type of Diabetes and Source of Care

    OpenAIRE

    Zaugg, Stephanie D.; Dogbey, Godwin; Collins, Karen; Reynolds, Sharon; Batista, Carter; Brannan, Grace; Shubrook, Jay H.

    2014-01-01

    Limited diabetes numeracy may be an important factor affecting diabetes care and treatment adherence. This study assessed the relationship between the Diabetes Numeracy Test (DNT-15 score) and patient and treatment variables. Patients who had type 1 diabetes and those who received care from specialty centers had higher levels of numeracy, but this did not translate into improved glucose control.

  5. 21 CFR 640.5 - Testing the blood.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 7 2010-04-01 2010-04-01 false Testing the blood. 640.5 Section 640.5 Food and... ADDITIONAL STANDARDS FOR HUMAN BLOOD AND BLOOD PRODUCTS Whole Blood § 640.5 Testing the blood. All laboratory tests shall be made on a specimen of blood taken from the donor at the time of collecting the unit...

  6. Serum progranulin concentrations are not responsive during oral lipid tolerance test and oral glucose tolerance test.

    Science.gov (United States)

    Schmid, A; Leszczak, S; Ober, I; Schäffler, A; Karrasch, T

    2015-07-01

    The postprandial regulation of progranulin by oral uptake of lipids and carbohydrates in healthy individuals has not yet been investigated. The regulation of progranulin in 2 large cohorts of healthy volunteers during oral lipid tolerance test (OLTT; n=100) and oral glucose tolerance test (OGTT; n=100) was analyzed. One hundred healthy volunteers underwent OLTT and OGTT in an outpatient setting. Venous blood was drawn at 0 hours (h) (fasting) and at 2, 4, and 6 h in OLTT or 1 and 2 h in OGTT. A novel OLTT solution completely free of carbohydrates and protein was applied. Subjects were characterized by anthropometric and laboratory parameters. Serum concentrations of progranulin were measured by enzyme-linked immunosorbent assay (ELISA). Circulating progranulin levels remained unchanged during OLTT and OGTT. Fasting progranulin levels ranged between 31.3±8.7 and 40.6±7.7 ng/ml and were not different in subgroups addressing BMI, gender, family history, smoking habits, and hormonal contraception. There was a reciprocal correlation of progranulin with HDL (negative) and LDL cholesterol levels (positive). In healthy adults, fasting and postprandial circulating progranulin levels are not different in BMI subgroups. Oral uptake of carbohydrates and lipids does not influence circulating progranulin levels in a short-term manner. A postprandial and short-term regulation of this adipokine is absent, at least in healthy subjects. There is a negative correlation of progranulin with HDL cholesterol, but a positive correlation with LDL cholesterol. This reciprocal association might be of physiological importance for an individual's atherosclerotic risk. PMID:25565096

  7. 四种血糖仪与全自动生化仪检测血糖结果比较分析%Comparison of periphery capillary whole blood glucose using four kinds of blood glucose meters and venous plasma glucose using laboratory auto-analyzer

    Institute of Scientific and Technical Information of China (English)

    吴南楠; 王萌; 赵冬

    2015-01-01

    laboratory,95% of the CBG test results detected by four kinds of blood glucose meters were in the range of ± 20%.Conclusion The four kinds of glucose monitors can provide high accurate.

  8. A Risk Based Neural Network Approach for Predictive Modeling of Blood Glucose Dynamics.

    Science.gov (United States)

    Frandes, Mirela; Timar, Bogdan; Lungeanu, Diana

    2016-01-01

    For type 1 diabetes patients, maintaining the blood glucose (BG) at normal values is a challenging task due to e.g. variable insulin reactions, diets, lifestyles, emotional conditions, etc. Hyperglycemic and hypoglycemic events can generate various complications (e.g. diabetic ketoacidosis, retinopathy, neuropathy, etc.), so predicting BG values in time is of great importance for diabetes self-management. Herein, we propose a non-linear autoregressive neural network approach, based on the minimal dataset available from a continuous glucose monitoring (CGM) sensor, with an integrated measure of intra-patient BG variability. The method kept the balance between accuracy and complexity, allowing a fast response with no additional effort or discomfort for the patient. PMID:27577449

  9. Cerebral oxygen and glucose metabolism and blood flow in mitochondrial encephalomyopathy: a PET study

    International Nuclear Information System (INIS)

    Cerebral blood flow (CBF), oxygen metabolism (CMRO2), and glucose metabolism (CMRGlc) were measured using positron emission tomography in five patients diagnosed as having mitochondrial encephalomyopathy. The molar ratio between the oxygen and glucose consumptions was reduced diffusely, as CMRO2 was markedly decreased and CMRGlc was slightly reduced. The CBF showed less changes. The CBF increase on hypercapnia was smaller than normal, though this was not significant. CBF with hypocapnia demonstrated a significant reduction compared with the normal. These results suggest that oxidative metabolism is impaired and anaerobic glycolysis relatively stimulated, due to a primary defect of mitochondrial function, and that mild lactic acidosis occurs in brain tissue because of impaired utilisation of pyruvate in the TCA cycle. As these findings appear to indicate directly a characteristic of this disease, such measurements may be a useful tool for assessment of the pathophysiology and for diagnosis of mitochondrial encephalomyopathy. (orig.). With 1 fig., 4 tabs

  10. Fabrication of glucose biosensor for whole blood based on Au/hyperbranched polyester nanoparticles multilayers by antibiofouling and self-assembly technique

    International Nuclear Information System (INIS)

    Highlight: •A novel method for detection of glucose in whole blood has been developed. •The method based on antibiofouling and self-assembly technology was investigated. •The antibiofouling technique utilized for sensor is significant for diagnostics. -- Abstract: Acknowledging the benefits of hyperbranched polymers and their nanoparticles, herein we report the design and synthesis of sulfonic acid group functionalized hydroxyl-terminated hyperbranched polyester (H30-SO3H) nanoparticles and their biomedical application. The H30-SO3H nanoparticles were characterized by transmission electron microscopy (TEM), Fourier transform infrared (FTIR) spectroscopy and proton nuclear magnetic resonance spectroscopy (1H NMR). The good hemocompatibility of H30-SO3H nanoparticles was also investigated by coagulation tests, complement activation and platelet activation. The novel glucose biosensor was fabricated by immobilizing the positively charged Au nanoparticles, H30-SO3H nanoparticles and glucose oxidase (GOx) onto the surface of glassy carbon electrode (GCE). It can be applied in whole blood directly, which was based on the good hemocompatibility and antibiofouling property of H30-SO3H nanoparticles. The biosensor had good electrocatalytic activity toward glucose with a wide linear range (0.2–20 mM), a low detection limit 1.2 × 10−5 M in whole blood and good anti-interference property. The development of materials science will offer a novel platform for application to substance detection in whole blood

  11. The effect of nano-curcumin on HbA1c, fasting blood glucose, and lipid profile in diabetic subjects: a randomized clinical trial

    Directory of Open Access Journals (Sweden)

    Hamid Reza Rahimi

    2016-08-01

    Full Text Available Objective: Diabetes mellitus is defined as a group of metabolic diseases characterized by hyperglycemia resulting from defects in insulin secretion, insulin action, or both or insulin resistance. Curcumin inhibits NF-κB signaling pathway. The aim of this study is evaluation of the effect of Nano-curcumin on HbA1C, fast blood glucose and lipid profile in diabetic patients. Materials and Methods: Seventy type-2 diabetic patients (fasting blood glucose (FBG ≥ 126 mg/dL or 2-hr postprandial blood glucose ≥200 mg/dl randomly receivedeither Curcumin (as nano-micelle 80 mg/day or placebo for 3 months in a double blind randomized clinical trial. Fasting blood glucose, HbA1C, and lipids profile were checked before and after the intervention. Data analyses, including parametric and nonparametric tests were done using the SPSS 11.5 software. A p value < 0.05 was regarded as statistically significant. (RCT registration code: IRCT2013081114330N1 Results: Mean age, BMI, FBG, total cholesterol (TC, triglyceride (TG, LDL, HDL, HbA1c , and  sex and had no significant difference at the baseline between the groups. In Nano-curcumin group, a significant decrease was found in HbA1C, FBG, TG, and BMI comparing results of each subject before and after the treatment (p

  12. The effect of nano-curcumin on HbA1c, fasting blood glucose, and lipid profile in diabetic subjects: a randomized clinical trial

    Science.gov (United States)

    Rahimi, Hamid Reza; Mohammadpour, Amir Hooshang; Dastani, Mostafa; Jaafari, Mahmoud Reza; Abnous, Khalil; Ghayour Mobarhan, Majid; Kazemi Oskuee, Reza

    2016-01-01

    Objective: Diabetes mellitus is defined as a group of metabolic diseases characterized by hyperglycemia resulting from defects in insulin secretion, insulin action, or both or insulin resistance. Curcumin inhibits NF-κB signaling pathway. The aim of this study is evaluation of the effect of Nano-curcumin on HbA1C, fast blood glucose and lipid profile in diabetic patients. Materials and Methods: Seventy type-2 diabetic patients (fasting blood glucose (FBG) ≥ 126 mg/dL or 2-hr postprandial blood glucose ≥200 mg/dl) randomly receivedeither Curcumin (as nano-micelle 80 mg/day) or placebo for 3 months in a double blind randomized clinical trial. Fasting blood glucose, HbA1C, and lipids profile were checked before and after the intervention. Data analyses, including parametric and nonparametric tests were done using the SPSS 11.5 software. A p value cholesterol (TC), triglyceride (TG), LDL, HDL, HbA1c , and sex and had no significant difference at the baseline between the groups. In Nano-curcumin group, a significant decrease was found in HbA1C, FBG, TG, and BMI comparing results of each subject before and after the treatment (pcurcumin in type-2 diabetes; also, it is partially decrease in serum LDL-C and BMI. PMID:27761427

  13. Fabrication of glucose biosensor for whole blood based on Au/hyperbranched polyester nanoparticles multilayers by antibiofouling and self-assembly technique

    Energy Technology Data Exchange (ETDEWEB)

    Sun, Chong [Jiangsu Key Laboratory of Biofunctional Materials, College of Chemistry and Materials Science, Nanjing Normal University, Nanjing 210023 (China); Key Laboratory for Soft Chemistry and Functional Materials of Ministry of Education, School of Chemical Engineering, Nanjing University of Science and Technology, Nanjing 210094 (China); Chen, Xiaohan; Han, Qiaorong [Jiangsu Key Laboratory of Biofunctional Materials, College of Chemistry and Materials Science, Nanjing Normal University, Nanjing 210023 (China); Zhou, Min [Department of Vascular Surgery, the Affiliated Drum Tower Hospital of Nanjing University Medical School, Nanjing 210008 (China); Mao, Chun, E-mail: maochun127@yahoo.cn [Jiangsu Key Laboratory of Biofunctional Materials, College of Chemistry and Materials Science, Nanjing Normal University, Nanjing 210023 (China); Zhu, Qinshu [Jiangsu Key Laboratory of Biofunctional Materials, College of Chemistry and Materials Science, Nanjing Normal University, Nanjing 210023 (China); Shen, Jian, E-mail: jshen@njnu.edu.cn [Jiangsu Key Laboratory of Biofunctional Materials, College of Chemistry and Materials Science, Nanjing Normal University, Nanjing 210023 (China)

    2013-05-07

    Highlight: •A novel method for detection of glucose in whole blood has been developed. •The method based on antibiofouling and self-assembly technology was investigated. •The antibiofouling technique utilized for sensor is significant for diagnostics. -- Abstract: Acknowledging the benefits of hyperbranched polymers and their nanoparticles, herein we report the design and synthesis of sulfonic acid group functionalized hydroxyl-terminated hyperbranched polyester (H30-SO{sub 3}H) nanoparticles and their biomedical application. The H30-SO{sub 3}H nanoparticles were characterized by transmission electron microscopy (TEM), Fourier transform infrared (FTIR) spectroscopy and proton nuclear magnetic resonance spectroscopy ({sup 1}H NMR). The good hemocompatibility of H30-SO{sub 3}H nanoparticles was also investigated by coagulation tests, complement activation and platelet activation. The novel glucose biosensor was fabricated by immobilizing the positively charged Au nanoparticles, H30-SO{sub 3}H nanoparticles and glucose oxidase (GOx) onto the surface of glassy carbon electrode (GCE). It can be applied in whole blood directly, which was based on the good hemocompatibility and antibiofouling property of H30-SO{sub 3}H nanoparticles. The biosensor had good electrocatalytic activity toward glucose with a wide linear range (0.2–20 mM), a low detection limit 1.2 × 10{sup −5} M in whole blood and good anti-interference property. The development of materials science will offer a novel platform for application to substance detection in whole blood.

  14. Breath acetone concentration decreases with blood glucose concentration in type I diabetes mellitus patients during hypoglycaemic clamps

    OpenAIRE

    Turner, Claire; Walton, Christopher; Hoashi, Shu; Evans, Mark

    2009-01-01

    Conventional wisdom is that breath acetone may be markedly elevated in type 1 diabetes, but that this only occurs during poor blood glucose control and/or intercurrent illness. In contrast, little is known about breath acetone at more representative everyday blood glucose levels in diabetes. We used selected ion flow tube mass spectrometry (SIFT-MS) to monitor the breath of 8 patients with type 1 diabetes mellitus during “insulin clamp” studies in which insulin and glucose were infused into p...

  15. Effects of Cinnamomum zeylanicum (Ceylon cinnamon) on blood glucose and lipids in a diabetic and healthy rat model

    OpenAIRE

    Priyanga Ranasinghe; Sanja Perera; Mangala Gunatilake; Eranga Abeywardene; Nuwan Gunapala; Sirimal Premakumara; Kamal Perera; Dilani Lokuhetty; Prasad Katulanda

    2012-01-01

    Objectives: To evaluate short- and long-term effects of Cinnamomum zeylanicum on food consumption, body weight, glycemic control, and lipids in healthy and diabetes-induced rats. Materials and Methods: The study was conducted in two phases (Phase I and Phase II), using Sprague-Dawley rats in four groups. Phase I evaluated acute effects on fasting blood glucose (FBG) (Groups 1 and 2) and on post-oral glucose (Groups 3 and 4) blood glucose. Groups 1 and 3 received distilled-water and Groups 2 a...

  16. Effect of Butea monosperma Lam. leaves and bark extracts on blood glucose in streptozotocin-induced severely diabetic rats

    Directory of Open Access Journals (Sweden)

    Faiyaz Ahmed

    2012-01-01

    Full Text Available Background: Diabetes mellitus is a chronic metabolic disorder that has significant impact on the health, quality of life and life expectancy, as well as on the health care system. Butea monosperma Lam. Kuntze (Fabaceae, commonly known as palash, is widely used in the treatment of various diseases and disorders including diabetes. Materials and Methods: The present study was planned to evaluate the antidiabetic effect of aqueous extracts of B. monosperma leaves and bark in streptozotocin-induced severely diabetic rats. The animals were divided into four groups, with each consisting of six rats, viz. control, diabetic control, leaf extract-treated and bark extract-treated groups. Treatment was continued for 6 weeks. The biochemical estimations included blood glucose and serum insulin levels. Histopathology of pancreas was also performed. Results: The results indicated that both leaf and bark extracts of B. monosperma produced insignificant antihyperglycemic activity. The leaf and bark extracts reduced blood glucose to an extent of 28% and 11%, respectively. It was also evidenced that both leaf and bark extracts did not increase insulin synthesis or secretion and did not improve pancreatic architecture as reflected by the histopathologic studies. Conclusions: The findings of the study emphasize that B. monosperma does not possess significant antidiabetic activity in severe experimental diabetes at the dosage tested.

  17. Subarachnoid hemorrhage in the rat: cerebral blood flow and glucose metabolism during the late phase of cerebral vasospasm

    International Nuclear Information System (INIS)

    A double-isotope technique for the simultaneous measurement of CBF and CMRglu was applied to a subarachnoid hemorrhage (SAH) model in the rat. Cisternal injection of 0.07 ml blood caused a rather uniform 20% reduction in CBF together with an increase in glucose utilization of 30% during the late phase of vasospasm. In one-third of the SAH animals, there were focal areas where the flow was lowered to 30% of the control values and the glucose uptake increased to approximately 250% of control. We suggest that blood in the subarachnoid space via a neural mechanism induces the global flow and metabolic changes, and that the foci are caused by vasospasm superimposed on the global flow and metabolic changes. In the double-isotope autoradiographic technique, [14C]iodoantipyrine and [3H]deoxyglucose were used for CBF and CMRglu measurements, respectively, in the same animal. In half of the sections, the [14C]iodoantipyrine was extracted using 2,2-dimethoxypropane before the section was placed on a 3H- and 14C-sensitive film. The other sections were placed on x-ray film with an emulsion insensitive to 3H. The validity of the double-isotope method was tested by comparing the data with those obtained in animals receiving a single isotope. The CBF and metabolic values obtained in the two groups were similar

  18. Alternate Immersion in an External Glucose Solution Differentially Affects Blood Sugar Values in Older Versus Younger Zebrafish Adults.

    Science.gov (United States)

    Connaughton, Victoria P; Baker, Cassandra; Fonde, Lauren; Gerardi, Emily; Slack, Carly

    2016-04-01

    Recently, zebrafish have been used to examine hyperglycemia-induced complications (retinopathy and neuropathy), as would occur in individuals with diabetes. Current models to induce hyperglycemia in zebrafish include glucose immersion and streptozotocin injections. Both are effective, although neither is reported to elevate blood sugar values for more than 1 month. In this article, we report differences in hyperglycemia induction and maintenance in young (4-11 months) versus old (1-3 years) zebrafish adults. In particular, older fish immersed in an alternating constant external glucose solution (2%) for 2 months displayed elevated blood glucose levels for the entire experimental duration. In contrast, younger adults displayed only transient hyperglycemia, suggesting the fish were acclimating to the glucose exposure protocol. However, modifying the immersion protocol to include a stepwise increasing glucose concentration (from 1% → 2%→3%) resulted in maintained hyperglycemia in younger zebrafish adults for up to 2 months. Glucose-exposed younger fish collected after 8 weeks of exposure also displayed a significant decrease in wet weight. Taken together, these data suggest different susceptibilities to hyperglycemia in older and younger fish and that stepwise increasing glucose concentrations of 1% are required for maintenance of hyperglycemia in younger adults, with higher concentrations of glucose resulting in greater increases in blood sugar values. PMID:26771444

  19. Cost effectiveness and cost utility of the noncoding blood glucose meter CONTOUR® TS

    Directory of Open Access Journals (Sweden)

    Przemyslaw Holko

    2011-02-01

    Full Text Available Przemyslaw Holko, Pawal KawalecHTA Centre, Kraków, PolandAims: This study assessed the cost efficacy and cost utility of the automatic blood glucose meter CONTOUR® TS from the public payer (National Health Fund [NHF] and payer (patient and NHF perspectives over a 26-year analysis horizon.Methods: Clinical effectiveness data were obtained from prior clinical studies of automatic versus manually coded blood glucose meters. Cost data were obtained from the NHF. The probability of procedure use related to diabetic complications was obtained from four medical centers in Poland. The incremental cost-effectiveness ratio related to 1 life year gained and the incremental cost-utility ratio related to 1 quality-adjusted life year gained were calculated.Results: Assuming co-funding from public funds, introduction of the CONTOUR® TS is associated with savings of Polish złoty (PLN 31,846.19 (€8916.93 and PLN 113,018.19 (€31,645.09 per life year gained from the payer and public payer perspectives, respectively. Cost utility analyses showed that the CONTOUR® TS is associated with savings of PLN 40,465.59 (€11,330.37 and PLN 11,434.82 (€3201.75 per quality-adjusted life year gained from the payer and the public payer perspectives, respectively.Conclusion: The CONTOUR® TS appears superior to manually coded meters available in Poland both from the payer and the public payer perspectives and may represent an improved strategy for glycemic control.Keywords: blood glucose self monitoring, costs and cost analysis, health care costs, diabetes mellitus, diabetes complications 

  20. The Influence of Eleutheroside on Blood Glucose and Blood Lipid of D-Galactose-Induce Rats through Inhibiting Blood Superoxide Dismutase Activities

    Directory of Open Access Journals (Sweden)

    Ping Yang

    2013-07-01

    Full Text Available The present study aims at evaluation mechanisms of natural plant eleutheroside extracts for ameliorating the blood lipid and blood glucose. The eleutherosides derived from the roots of eleutheroccus senticosus and is purported to behave as an “adaptogen”, we assessed effects of eleutheroside at doses of 3.6, 7.2 and 14.4 g/(kg day on SD rats injected daily with D-gal (50 mg/(kg day. Eleutheroside-fed rats showed higher the level HDL-C, decrease the level of HCT, TG, TC, LDL-C compared with D-gal-treated rats. We further examined the mechanisms involved in effects of 3.63.6, 7.2 and 14.4 g/(kg day on rat blood. In summary, eleutheroside significantly increased Superoxide Dismutase (SOD activity and decreased the Malondialdehyde (MDA level.

  1. Patient and healthcare professional satisfaction with a new, high accuracy blood glucose meter with color range indicator and wireless connectivity.

    Science.gov (United States)

    Katz, Laurence B; Grady, Mike; Stewart, Lorna; Cameron, Hilary

    2016-07-01

    Accurate self-monitoring of blood glucose is a key component of effective self-management of glycemic control. The OneTouch VerioFlex(™) (OTVF) blood glucose monitoring system (BGMS) was evaluated for accuracy in a clinical setting. Patients also used OTVF for a 1-wk trial period and reported their level of satisfaction with meter features. In a separate study, healthcare professionals used an on-line simulator of the BGMS and answered questions about its potential utility to their patients. OTVF was accurate over a wide glucose range and met lay user and system accuracy blood glucose standards described in ISO15197:2013 as well as the accuracy requirements to fulfill US FDA expectations for 510(k) clearance of BGMS. Patients and healthcare professionals felt the features of OTVF, which has the capability to connect wirelessly to mobile devices and interact wirelessly with diabetes management software, could provide significant benefits to them or their patients. PMID:27232211

  2. Integrated Self-Monitoring of Blood Glucose System: Handling Step Analysis

    OpenAIRE

    Freckmann, Guido; Schmid, Christina; Ruhland, Katharina; Baumstark, Annette; Haug, Cornelia

    2012-01-01

    Self-monitoring of blood glucose (SMBG) implicates a number of handling steps with the meter and the lancing device. Numerous user errors can occur during SMBG, and each step adds to the complexity of use. This report compares the required steps to perform SMBG of one fully integrated (the second generation of the Accu-Chek® Mobile), three partly integrated (Accu-Chek Compact Plus, Ascensia® Breeze®2, and Accu-Chek Aviva), and six conventional (Bayer Contour®, Bayer Contour USB, BGStar™, Free...

  3. The efficacy of karkadeh tea in controlling post-prandial blood glucose levels

    DEFF Research Database (Denmark)

    Harrison, Adrian Paul; Cooper, Ross Gordon; Suliman, Moustafa Ahmed;

    2009-01-01

    Problem Statement: Increasing interest from the general public to use herbal remedies, exposes a considerable need to document ancient medical practices, as well as to investigate the efficacy of "ancient" compounds currently reputed to have medicinal benefits for such diseases as diabetes......, a slower rise to maximum levels and a greater Area Under the Curve (AUC) in terms of blood glucose was noted for the karkadeh tea plus a high glycemic index food cf. that of water imbibition with an identical high glycemic food. Conclusions/Recommendations: Karkadeh tea appears to have an efffect in terms...

  4. Impact of time since last caloric intake on blood glucose levels

    OpenAIRE

    Moebus, Susanne; Göres, Laura; Lösch, Christian; Jöckel, Karl-Heinz

    2011-01-01

    Blood glucose (BG) is usually measured after a caloric restriction of at least 8 h; however evidence-based recommendations for the duration of a fasting status are missing. Here we analyze the effect of fasting duration on levels of BG to determine the minimal fasting duration to achieve comparable BG levels to conventional fasting measurements. We used data of a cross-sectional study on primary care patients, performed in October 2005. We included 28,024 individuals (age-range 18–99 years; 6...

  5. Effect of Vit C Supplement on Fasting Blood Glucose and Plasma Lipid Level in Type II Diabetic Patients

    Directory of Open Access Journals (Sweden)

    Mehri Delvarianzadeh

    2008-01-01

    Full Text Available Introduction: Diabetic people are more at risk of diseases such as vascular, kidneys and eye diseases, compared with normal people. Since Vit C competitively replaces glucose in most chemical reactions; so inhibit on non enzymatic glycosylation such as hemoglobin and lipoproteins, it seems that Vit C can be effective to prevent diabetic complications .In this study effect of Vit C supplements on blood sugar and fats level in type II diabetic patients was investigated. Methods: This study was conducted as a clinical trial using paired random sampling on 136 type II diabetic patients. At first, the patients weights, age, type of diet were recorded .Then their fasting blood glucose (FBS, glycosylated hemoglobin (HbAIC, Cholesterol, triglyceride, HDL and LDL were measured. After that the patients were divided in two randomized groups. The first group (control was subject of administration of Vit C supplement (1250 mg, 5 times a day, for a period of 3 months and the second group received placebo. Data were analyzed by paired t- test and SPSS Software. Results: In this study most of patients were women (62.2% of control group and 64.7% of placebo group. The mean age between the control group and placebo group were reported 51.2 ± 6.8 and 50.37± 9.71 years respectively. At the end of study , after 3 months of administration of Vit C supplement to control group, the mean concentration of FBS, LDL triglyceride Cholesterol and glycosylated hemoglobin has been reduced significantly with respect to the placebo group and the mean value of HDL has been increased as well. Conclusion: The finding shows that Vit C supplements might reduce the amount of glucose, lipids and glycosylated hemoglobin in patients with type 2 diabetes. Therefore, its consumption in diabetic patients can be recommended and as a result patient complications will be significantly reduced.

  6. Amantadine reduces glucagon and enhances insulin secretion throughout the oral glucose tolerance test: central plus peripheral nervous system mechanisms

    Directory of Open Access Journals (Sweden)

    Fuad Lechin

    2009-12-01

    Full Text Available Fuad Lechin1, Bertha van der Dijs1, Betty Pardey-Maldonado1, Jairo E Rivera1, Marcel E Lechin2, Scarlet Baez11Department of Physiological Sciences, Sections of Neuroendocrinology, Neuropharmacology, and Neurochemistry, Instituto de Medicina Experimental, Faculty of Medicine, Universidad Central de Venezuela, Caracas, Venezuela; 2Department of Internal Medicine, Texas A & M Health Science Center, College of Medicine, TX, USAObjective: The purpose of the trial was to examine the effects of amantadine, a N-methyl-D-aspartate (NMDA antagonist, on the oral glucose tolerance test (OGTT plus insulin, glucagon and neurotransmitters circulating levels. Previous findings showed that hyperinsulinism and type 2 diabetes are positively associated with neural sympathetic and adrenal sympathetic activities, respectively. These peripheral sympathetic branches depend on the pontine (A5-noradrenergic and the rostral ventrolateral (C1-adrenergic medullary nuclei. They are excited by glutamate axons which act at NMDA postsynaptic receptors.Research design and methods: One OGTT plus placebo and one OGTT plus oral amantadine test were carried out two weeks apart in 15 caucasic normal voluntary humans. Noradrenaline, adrenaline, dopamine, plasma-free serotonin, platelet serotonin, glucose, glucagon, and insulin were measured throughout the 180-minute testing period.Results: Maximal reductions of plasma glucose and glucagon plus exacerbated insulin rises were significantly greater throughout the oral glucose plus amantadine test than those registered throughout the oral glucose plus placebo challenge. The above findings were paralleled by greater than normal noradrenaline/adrenaline plasma ratio increases. In addition, maximal reductions of the platelet serotonin and plasma serotonin circulating values contrasted with the normal rises of these parameters, always registered during the glucose load plus placebo challenge.Conclusion: This study supports the theory that

  7. Polyphenol- and fibre-rich dried fruits with green tea attenuate starch-derived postprandial blood glucose and insulin: a randomised, controlled, single-blind, cross-over intervention.

    Science.gov (United States)

    Nyambe-Silavwe, H; Williamson, G

    2016-08-01

    Polyphenol- and fibre-rich foods (PFRF) have the potential to affect postprandial glycaemic responses by reducing glucose absorption, and thus decreasing the glycaemic response of foods when consumed together. A randomised, single-blind, cross-over study was conducted on sixteen healthy volunteers to test whether PFRF could attenuate postprandial blood glucose in healthy volunteers when added to a source of carbohydrate (starch in bread). This is the first study to examine the effects of a meal comprised of components to inhibit each stage of the biochemical pathway, leading up to the appearance of glucose in the blood. The volunteers were fasted and attended four visits: two control visits (bread, water, balancing sugars) and two test visits (single and double dose of PFRF) where they consumed bread, water and PFRF. Blood samples were collected at 0 (fasted), 15, 30, 45, 60, 90, 120, 150 and 180 min after consumption. The PFRF components were tested for α-amylase and α-glucosidase inhibitory potential in vitro. Plasma glucose was lower after consumption of both doses compared with controls: lower dose, change in mean incremental areas under the glucose curves (IAUC)=-27·4 (sd 7·5) %, Pamylase (green tea, strawberry, blackberry and blackcurrant) and α-glucosidase (green tea) activities in vitro. The PFRF have a pronounced and significant lowering effect on postprandial blood glucose and insulin response in humans, due in part to inhibition of α-amylase and α-glucosidase, as well as glucose transport. PMID:27278405

  8. [Effect of a dehydrated extract of nopal (Opuntia ficus indica Mill.) on blood glucose].

    Science.gov (United States)

    Frati-Munari, A C; de León, C; Ariza-Andraca, R; Bañales-Ham, M B; López-Ledesma, R; Lozoya, X

    1989-01-01

    To assess if a dehydrated extract of nopal stems retains the effect on glycemia of the entire nopal stems two experiments were performed. A. Six patients with type II diabetes mellitus in fasting condition received 30 capsules containing 10.1 +/- 0.3 g of the extract, and serum glucose levels were measured hourly from 0 to 180 minutes. B. Six healthy volunteers received 30 capsules with the extract followed by 74 g of dextrose orally. Serum glucose measurements were made in a similar fashion. In each experiment a control test with empty capsules was performed. Nopal extract did not reduce fasting glycemia in diabetic subjects. Nevertheless, the extract diminished the increase of serum glucose which followed a dextrose load. Peak serum glucose was 20.3 +/- 18.2 mg/dl (X +/- SD) lower in the test with nopal than in the control one (P less than 0.025). Dehydrated extract of nopal (Opuntia ficus-indica Mill) did not show acute hypoglycemic effect, although could attenuate postprandial hyperglycemia. PMID:2561256

  9. Hemoglobin A1c Versus Oral Glucose Tolerance Test in Postpartum Diabetes Screening

    OpenAIRE

    Picón, María José; Murri, Mora; Muñoz, Araceli; Fernández-García, José Carlos; Gomez-Huelgas, Ricardo; Tinahones, Francisco J.

    2012-01-01

    OBJECTIVE To determine the usefulness of measuring hemoglobin A1c (A1C), alone or combined with the fasting glucose test, compared with the oral glucose tolerance test (OGTT) for the reassessment of the carbohydrate metabolism status in postpartum women with a history of gestational diabetes mellitus (GDM). RESEARCH DESIGN AND METHODS We evaluated the status of carbohydrate metabolism by performing the OGTT and fasting glucose and A1C tests in 231 postpartum women with prior GDM 1 year after ...

  10. Design of a prospective clinical study on the agreement between the Continuous GlucoseMonitor, a novel device for CONTinuous ASSessment of blood GLUcose levels, and the RAPIDLab® 1265 blood gas analyser: The CONTASSGLU study

    Directory of Open Access Journals (Sweden)

    Zimmermann Johannes B

    2012-09-01

    Full Text Available Abstract Background Although a device is needed to continuously measure blood glucose levels within an intensive care setting, and several large-scale prospective studies have shown that patients might benefit from intensive insulin, potassium, or glucose therapy during intensive care, no devices are currently available to continuously assess blood glucose levels in critically ill patients. We conceived the study described here to evaluate the clinical use of the Continuous Glucose Monitor (CGM performed via a central vein, and to determine the impact of phenomena, such as drift and shift, on the agreement between the CGM and a RAPIDLab® 1265 blood gas analyser (BGA. Methods/design In the CONTinuous ASSessment of blood GLUcose (CONTASSGLU study, up to 130 patients under intensive care will be fitted with the CGM, an ex vivo device that continuously measures blood glucose and lactate levels. Readings from the device taken 8 h after initial placement and calibration will be compared with values measured by a BGA. For this study, we chose the BGA as it is an established standard point-of-care device, instead of the devices used in certified central laboratories. Nevertheless, we will also independently compare the results from the point-of-care BGA with those determined by a central laboratory-based device. Blood samples will be collected from each patient from the same site in which the CGM will measure blood glucose. Consequently, each participant will serve as their own control, and no randomisation is necessary. The 95% limits of agreement and the corresponding confidence intervals will be calculated and compared with a prespecified clinically acceptable relative difference of 20%. Discussion Several attempts have been made to develop a device to continuously measure blood glucose levels within an intensive care setting or to use the devices that were originally designed for diabetes management, as several of these devices are already

  11. Effect of chicory seed extract on glucose tolerance test (GTT) and metabolic profile in early and late stage diabetic rats

    OpenAIRE

    Ghamarian Abdolreza; Abdollahi Mohammad; Su Xiaogang; Amiri Azita; Ahadi Ali; Nowrouzi Azin

    2012-01-01

    Abstract Background and purpose of the study The goal was to evaluate and compare the effects of aqueous extract of the seeds of chicory, Cichorium intybus L., on glucose tolerance test (GTT) and blood biochemical indices of experimentally-induced hyperglycemic rats. Methods Late stage and early stage of Type 2 diabetes mellitus (T2DM) were induced in rats by streptozotocin (STZ) and a combination of STZ and niacinamide (NIA/STZ), respectively. Within each group, one subgroup received daily i...

  12. Effect of Syzygium Aromaticum (CLOVE) Extract on Blood Glucose Level in Streptozotocin induced Diabetic Rats

    International Nuclear Information System (INIS)

    Objective: To evaluate the glucose lowering effect of 50% ethanol extract of Syzygium aromaticum in comparison with that of standard insulin in streptozotocin induced diabetic rats. Study Design: Randomized control trial. Place and Duration of Study: National Institute of Health Islamabad. Jul 2011- Dec 2011 Material and Methods: It was carried out on 48 adult rats of Sprague dawley specie. Rats were equally divided into 6 groups (I-VI). Group - I served as control. Diabetes was induced by giving single intraperitoneal injection of STZ in Group II to VI. Group-II served as diabetic control, while groups III, IV, V and VI served as experimental groups. Group III, IV and V rats received 50% ethanol extract of Syzygium aromaticum at a dose of 250, 500 and 750 mg/kg body weight respectively for sixty days. Group VI (standard) received humulin insulin 70/30 at dose of 0.6 units<-kg body weight subcutaneously bid for sixty days. Fasting blood samples were taken at zero day, 15 day, 30 day and 60 day after giving injection STZ. Although Syzygium aromaticum with the doses of 250, 500 and 750 mg/kg body weight and insulin reduced the level of glucose in rats but on comparison Syzygium aromaticum 750 mg=kg dose reduced glucose more effectively than 250 and 500 mg/kg dose. While in group III, IV subjects, blood glucose levels remained above normal level. In group VI receiving insulin the level of this parameter remained almost closer to group IV rats. On studying the weight of the animals after receiving STZ there was initial reduction in the weight of all the experimental groups but after receiving the extract of plant improvement was seen and the weight of group V getting 750 mg=kg/body weight of Syzygium aromaticum became almost closer to the weight of control group. Conclusion: Syzygium aromaticum extract has glucose lowering effect in STZ induced diabetic rats and this effect is dose related and the dose of 750 mg/kg body weight has produced maximum effect. (author)

  13. Dietary intake, food pattern, and abnormal blood glucose status of middle-aged adults: a cross-sectional community-based study in Myanmar

    Directory of Open Access Journals (Sweden)

    Hlaing Hlaing Hlaing

    2016-05-01

    Full Text Available Background: Lifestyle changes, particularly dietary intake, had resulted in increasing trends of type-2 diabetes mellitus worldwide. However, dietary intake is diverse across country contexts. This study aimed to compare the dietary intake, food patterns, and blood glucose among middle-aged adults living in urban and suburban areas in Mandalay city, Myanmar, and explore their relationships. Methods: A cross-sectional community-based study was conducted during June–November 2014. Adults aged 35–64 were randomly selected and requested to record all food they ate in a 4-day diary. Fasting and 2-hour postprandial blood glucose values were measured over two consecutive days. Dietary intakes were calculated in terms of energy, macronutrients, glycemic index, and glycemic load, and food patterns were identified by factor analysis. The relationships between food pattern, dietary intake, and blood glucose were assessed. Results: Of 440 participants, dietary intake between urban and suburban residents was significantly different. Six food patterns were identified. There was no difference in fasting and 2-hour postprandial blood glucose between urban and suburban residents, but a strong correlation between fasting blood glucose and 2-hour postprandial blood glucose was found (correlation coefficient=0.8. Identification of abnormal blood glucose status using original fasting and converted 2-hour postprandial values showed substantial agreement (prevalence-adjusted bias-adjusted Kappa= 0.8. Relationships between food patterns and blood glucose or abnormal blood glucose status were not found. Conclusion: Food patterns were associated with dietary intake, not with abnormal blood glucose status. Two-hour postprandial blood glucose was highly correlated with fasting blood glucose and may be used for identifying abnormal blood glucose status.

  14. 21 CFR 862.1130 - Blood volume test system.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Blood volume test system. 862.1130 Section 862...) MEDICAL DEVICES CLINICAL CHEMISTRY AND CLINICAL TOXICOLOGY DEVICES Clinical Chemistry Test Systems § 862.1130 Blood volume test system. (a) Identification. A blood volume test system is a device intended...

  15. 21 CFR 640.23 - Testing the blood.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 7 2010-04-01 2010-04-01 false Testing the blood. 640.23 Section 640.23 Food and... ADDITIONAL STANDARDS FOR HUMAN BLOOD AND BLOOD PRODUCTS Platelets § 640.23 Testing the blood. (a) Blood from... this chapter and § 640.5 (a), (b), and (c). (b) The tests shall be performed on a sample of...

  16. The management of blood glucose in ICU%ICU血糖监测和管理

    Institute of Scientific and Technical Information of China (English)

    钱娟; 王莹

    2012-01-01

    Hyper glycemia and hypoglycemia are associated with poor outcome of critically ill patients.No consistent evidence shows that intensive insulin strategy improves health outcomes in hospitalized patients.Because of its potentially harmful and life-threatening consequences,hypoglycemia represents the main limit to the development of a tight blood glucose control strategy in critical illness.Hypoglycemia-related neurological signs may be masked.The occurrence of hypoglycemia in critical illness,especially severe hypoglycemia,is associated with a poor prognosis.So it is necessary to closely detect glycemic variability and control the blood glucose in proper level.%ICU患儿出现高血糖和低血糖均与不良预后相关.在应激性高血糖管理中,目前并不提倡“严格血糖控制策略”,以避免低血糖等不良事件发生.在危重病患儿中低血糖相关的神经系统症状往往被掩盖,严重低血糖与不良预后、高病死率相关.因此ICU患儿密切监测血糖尤为重要,及时发现血糖异常变化予以正确处理.

  17. EFFECT OF REGULAR GARLIC INGESTION ON BODY WEIGHT AND BLOOD GLUCOSE: A CASE STUDY IN MICE

    Directory of Open Access Journals (Sweden)

    F.T. Djankpa, A. Osonuga*, J. Ekpale, C.E. Quaye, P. Otoo, O.A. Osonuga and S.K. Amoah

    2012-05-01

    Full Text Available Garlic a perennial erect plant is known to have sulphur-containing compounds that act on the hypothalamus increasing the sensitivity of the hypothalamus to leptin which alters the set point at which satiety is reached causing an organism to eat less. Nine mice (six of which were obese were used in this study and grouped into three. Groups A and B were made of 3 obese mice each whereas group C consisted of 3 non-obese mice. For group A and group C mice, 20 ml aqueous garlic extract was added to their feed daily whereas no garlic was added to the feed of group B mice. The study was carried out over a period of 44 days. The weight and blood glucose was measured weekly and the average for each group was computed. Results indicated that Group A mice recorded a reduction in mean body weight by 46.5% (p<0.05. Group B mice had significant increase in mean body weight by 46.2% (p<0.05. The blood glucose level dropped significantly by 18.5% (p<0.05 in group A mice. Garlic had weight loss and hypoglycemic effect in obese mice. These effects were absent in non-obese mice.

  18. Effects of Cinnamomum zeylanicum (Ceylon cinnamon on blood glucose and lipids in a diabetic and healthy rat model

    Directory of Open Access Journals (Sweden)

    Priyanga Ranasinghe

    2012-01-01

    Full Text Available Objectives: To evaluate short- and long-term effects of Cinnamomum zeylanicum on food consumption, body weight, glycemic control, and lipids in healthy and diabetes-induced rats. Materials and Methods: The study was conducted in two phases (Phase I and Phase II, using Sprague-Dawley rats in four groups. Phase I evaluated acute effects on fasting blood glucose (FBG (Groups 1 and 2 and on post-oral glucose (Groups 3 and 4 blood glucose. Groups 1 and 3 received distilled-water and Groups 2 and 4 received cinnamon-extracts. Phase II evaluated effects on food consumption, body weight, blood glucose, and lipids over 1 month. Group A (n = 8, distilled-water and Group B (n = 8, cinnamon-extracts were healthy rats, while Group C (n = 5, distilled-water and Group D (n = 5, cinnamon-extracts were diabetes-induced rats. Serum lipid profile and HbA1c were measured on D-0 and D-30. FBG, 2-h post-prandial blood glucose, body weight, and food consumption were measured on every fifth day. Results: Phase I: There was no significant difference in serial blood glucose values in cinnamon-treated group from time 0 (P > 0.05. Following oral glucose, the cinnamon group demonstrated a faster decline in blood glucose compared to controls (P < 0.05. Phase II: Between D0 and D30, the difference in food consumption was shown only in diabetes-induced rats (P < 0.001. Similarly, the significant difference following cinnamon-extracts in FBG and 2-h post-prandial blood glucose from D0 to D30 was shown only in diabetes-induced rats. In cinnamon-extracts administered groups, total and LDL cholesterol levels were lower on D30 in both healthy and diabetes-induced animals (P < 0.001. Conclusions: C. zeylanicum lowered blood glucose, reduced food intake, and improved lipid parameters in diabetes-induced rats.

  19. Impact of admission blood glucose level on outcomes in community-acquired pneumonia in older adults

    Directory of Open Access Journals (Sweden)

    Bhattacharya RK

    2013-05-01

    Full Text Available Rajib K Bhattacharya, Jonathan D Mahnken, Sally K RiglerUniversity of Kansas School of Medicine, Kansas City, KS, USABackground: Community-acquired pneumonia (CAP is a common cause of morbidity and mortality in older adults. Although diabetes mellitus is a risk factor for pneumonia, the clinical impact of blood glucose level at the time of admission is not clear. Our goal was to examine the association between admission hyperglycemia and subsequent mortality, length of stay, and readmission outcomes in older adults with CAP.Methods: A retrospective observational study was conducted using hospital data for community-acquired pneumonia admissions in 857 persons from January 1, 2008 to December 31, 2010. We examined the effects of admission glucose level on mortality, length of stay, and 30 day readmission, adjusted for demographic factors and comorbidity.Results: The mean age of the sample was 64 years, and 51% of the subjects were female. Inpatient mortality occurred in 4.6% and the median length of stay was 5 days (interquartile range 3–9 days. Readmission within 30 days occurred in 17%. We found little impact of first glucose measures on in-hospital mortality (P = 0.94, length of stay (P = 0.95, and 30-day readmission (P = 0.56. Subjects 65 years and older trended towards higher in-hospital mortality. Older age, cancer, heart failure, and cirrhosis were associated with adverse outcomes.Conclusion: Glucose level upon admission for community-acquired pneumonia was not associated with adverse outcomes within 30 days in older adults.Keywords: community-acquired pneumonia, hyperglycemia, readmission rates, hospital mortality

  20. Glucose-6-Phosphate Dehydrogenase Deficiency among Male Blood Donors in Sana’a City, Yemen

    Science.gov (United States)

    Al-Nood, Hafiz A.; Bazara, Fakiha A.; Al-Absi, Rashad; Habori, Molham AL

    2012-01-01

    Objectives To determine the prevalence of Glucose-6-phosphate dehydrogenase (G-6-PD) deficiency among Yemeni people from different regions of the country living in the capital city, Sana’a, giving an indication of its overall prevalence in Yemen. Methods A cross-sectional study was conducted among Yemeni male blood donors attending the Department of Blood Bank at the National Centre of the Public Health Laboratories in the capital city, Sana’a, Yemen. Fluorescent spot method was used for screening, spectrophotometeric estimation of G-6-PD activity and separation by electrophoresis was done to determine the G-6-PD phenotype. Results Of the total 508 male blood donors recruited into the study, 36 were G-6-PD deficient, giving a likely G-6-PD deficiency prevalence of 7.1%. None of these deficient donors had history of anemia or jaundice. Thirty-five of these deficient cases (97.2%) showed severe G-6-PD deficiency class II (<10% of normal activity), and their phenotyping presumptively revealed a G-6-PD-Mediterranean variant. Conclusion The results showed a significant presence of G-6-PD deficiency with predominance of a severe G-6-PD deficiency type in these blood donors in Sana’a City, which could represent an important health problem through occurrence of hemolytic anemia under oxidative stress. A larger sample size is needed to determine the overall prevalence of G-6-PD deficiency, and should be extended to include DNA analysis to identify its variants in Yemen. PMID:22359725

  1. Bedside monitoring of subcutaneous interstitial glucose in type 1 diabetic subjects using microdialysis and infrared spectrometry with optimal correlation to blood glucose concentrations

    Science.gov (United States)

    Heise, H. Michael; Damm, Uwe; Kondepati, Venkata R.; Mader, J. K.; Ellmerer, M.

    2007-02-01

    Infrared spectroscopy has been successfully employed in multi-component assays for the study of various biomedical samples. Two areas have found particular interest, i.e. in-vitro analysis in the clinical laboratory and point-of-care applications. With regard to the latter field, in-vivo blood glucose monitoring is an important topic for improving glycemic control in critically ill patients with non-adequate blood glucose regulation, similar to the situation faced for diabetic patients. For such application, a continuously operated mid-infrared spectroscopic system in combination with a subcutaneously implanted microdialysis probe and coupled by micro-fluidics has been developed. Using the dialysis process, the interstitial fluid matrix can be significantly simplified, since high molecular mass compounds such as proteins are separated. However, the micro-dialysis recovery rate is variable over time, so that a simultaneous determination of this parameter was implemented using the losses of an acetate marker from the perfusate across the dialysis membrane. Clinical measurements were carried out on type 1 diabetic subjects, with experiments lasting up to 28 hours. The concentrations of glucose, acetate and other components in the dialysates from interstitial body fluids were investigated. Two different multivariate calibration strategies, i.e. partial least squares (PLS) and classical least squares (CLS) regressions were applied. The results led to excellent correlation of the subcutaneous interstitial concentrations with those of laboratory blood glucose readings. Clarke-Error-Grid evaluations were employed for assessing the clinical applicability of the method.

  2. Effect of curcumin supplementation on blood glucose, plasma insulin, and glucose homeostasis related enzyme activities in diabetic db/db mice.

    Science.gov (United States)

    Seo, Kwon-Il; Choi, Myung-Sook; Jung, Un Ju; Kim, Hye-Jin; Yeo, Jiyoung; Jeon, Seon-Min; Lee, Mi-Kyung

    2008-09-01

    We investigated the effect of curcumin on insulin resistance and glucose homeostasis in male C57BL/KsJ-db/db mice and their age-matched lean non-diabetic db/+ mice. Both db/+ and db/db mice were fed with or without curcumin (0.02%, wt/wt) for 6 wks. Curcumin significantly lowered blood glucose and HbA 1c levels, and it suppressed body weight loss in db/db mice. Curcumin improved homeostasis model assessment of insulin resistance and glucose tolerance, and elevated the plasma insulin level in db/db mice. Hepatic glucokinase activity was significantly higher in the curcumin-supplemented db/db group than in the db/db group, whereas glucose-6-phosphatase and phosphoenolpyruvate carboxykinase activities were significantly lower. In db/db mice, curcumin significantly lowered the hepatic activities of fatty acid synthase, beta-oxidation, 3-hydroxy-3-methylglutaryl coenzyme reductase, and acyl-CoA: cholesterol acyltransferase. Curcumin significantly lowered plasma free fatty acid, cholesterol, and triglyceride concentrations and increased the hepatic glycogen and skeletal muscle lipoprotein lipase in db/db mice. Curcumin normalized erythrocyte and hepatic antioxidant enzyme activities (superoxide dismutase, catalase, gluthathione peroxidase) in db/db mice that resulted in a significant reduction in lipid peroxidation. However, curcumin showed no effect on the blood glucose, plasma insulin, and glucose regulating enzyme activities in db/+ mice. These results suggest that curcumin seemed to be a potential glucose-lowering agent and antioxidant in type 2 diabetic db/db mice, but had no affect in non-diabetic db/+ mice.

  3. Analysis of fasting blood glucose and glucose tolerance in 1 157 subjects%1157例体检者空腹血糖及糖耐量分析

    Institute of Scientific and Technical Information of China (English)

    王进

    2012-01-01

    Objective To analyze the fasting blood glucose(FBG) and glucose tolerance in 1 157 subjects accepting health examination to understand level and metabolism of blood glucose of local residents. Methods Adopting the method of population proportional sampling(PPS) , 1 157 subjects of all residents accepting health examination were randomly selected and divided into three groups according to economic conditions for the detection of FBG, among which 926 cases were detected for glucose tolerance by determination of blood glucose level 2 hours after oral intaking of 75 g glucose. Results 198 cases with high level of blood glucose and 117 cases with impaired glucose tolerance, accounting for 12. 63% , were demonstrated, and the prevalence of diabetes mellitus was 4. 86%. Conclusion The situation and prevalence of diabetes mellitus was serious in this region. Prevention of diabetes mellitus should be carried out from unban with better economic condition to other regions until the whole region.%目的 对1 157例体检者空腹血糖及糖耐量分析,掌握该区居民的血糖及其代谢情况.方法 采用人口成比例抽样(PPS)的方法,按经济条件分成3个层次,随机抽取1 157例研究对象采用葡萄糖氧化酶法测定空腹血糖,其中926例口服75 g无水葡萄糖2 h后测量血糖.结果 共计检出高血糖患者198例,检出糖耐量受损者117例,占12.63%,糖尿病患病率则为4.86%.结论 该区糖尿病患者及潜在者形势严峻,该区当前糖尿病防治应以经济较好的市区为重点向开发区辐射直至全区.

  4. Suppressive response of confections containing the extractive from leaves of Morus Alba on postprandial blood glucose and insulin in healthy human subjects

    Directory of Open Access Journals (Sweden)

    Oku Tsuneyuki

    2009-07-01

    Full Text Available Abstract Background The first aim of this study was to clarify the effective ratio of extractive from leaves of Morus Alba (ELM to sucrose so as to apply this knowledge to the preparation of confections that could effectively suppress the elevation of postprandial blood glucose and insulin. The second aim was to identify the efficacy of confections prepared with the optimally effective ratio determined from the first study, using healthy human subjects. Methods Ten healthy females (22.3 years, BMI 21.4 kg/m2 participated in this within-subject, repeated measures study. For the first aim of this study, the test solutions containing 30 g of sucrose and 1.2 or 3.0 g of ELM were repeatedly and randomly given to each subject. To identify the practically suppressive effects on postprandial blood glucose and insulin, some confections with added ELM were prepared as follows: Mizu-yokan, 30 g of sucrose with the addition of 1.5 or 3.0 g ELM; Daifuku-mochi, 9.0 g of starch in addition to 30 g of sucrose and 1.5 or 3.0 g ELM; Chiffon-cake, 24 g of sucrose, starch, and 3.0 or 6.0 g of ELM, and were ingested by each subject. Blood and end-expiration were collected at selected periods after test food ingestion. Results When 30 g of sucrose with 1.2 or 3.0 g of ELM were ingested by subjects, the elevations of postprandial blood glucose and insulin were effectively suppressed (p p Conclusion ELM-containing confections for which the ratio of ELM and sucrose is one-tenth effectively suppress the postprandial blood glucose and insulin by inhibiting the intestinal sucrase, thus creating a prebiotic effect. The development of confections with ELM can therefore contribute to the prevention and the quality of life for prediabetic and diabetic patients.

  5. The acute impact of ingestion of breads of varying composition on blood glucose, insulin and incretins following first and second meals.

    Science.gov (United States)

    Najjar, Anita Mofidi; Parsons, Patricia M; Duncan, Alison M; Robinson, Lindsay E; Yada, Rickey Y; Graham, Terry E

    2009-02-01

    Structural characteristics and baking conditions influence the metabolic responses to carbohydrate-containing foods. We hypothesized that consumption of whole wheat or sourdough breads would have a favourable effect on biomarkers of glucose homeostasis after first and second meals, compared with those for white bread. Ten overweight volunteers consumed 50 g available carbohydrate of each of the four breads (white, whole wheat, sourdough, whole wheat barley) followed 3 h later by a standard second meal. Blood was sampled for 3 h following bread ingestion and a further 2 h after the second meal for determination of glucose, insulin, paracetamol (indirect marker of gastric emptying), glucose-dependent insulinotropic polypeptide (GIP) and glucagon-like peptide-1 (GLP-1). Glucose and GLP-1 responses to sourdough bread were lower (P breads. Glucose area under the curve (AUC) for sourdough bread was lower than those for whole wheat (P breads for the entire study. GIP AUC after sourdough bread ingestion was lower compared to white (P breads following the second meal. There were no significant differences in insulin and paracetamol concentrations among the test breads. Ultra-fine grind whole wheat breads did not result in postprandial responses that were lower than those of white bread, but sourdough bread resulted in lower glucose and GLP-1 responses compared to those of these whole wheat breads following both meals.

  6. Evaluation of blood glucose and thyroid function in Sudanese diabetic patients

    International Nuclear Information System (INIS)

    This study composes of two parts. The first one is a survey of thyroid abnormalities, and the second one is experiment to estimate the level of thyroid hormones (T4, T3, TSH) among diabetic population and the relationship between the level of glucose, thyroid hormones and lipid profile (TC, LDL, TG, HDL) and comparison of the results with non diabetic group. The survey part of the study to determine the thyroid abnormalities, hypothyroidism or hyperthyroidism clinical or subclinical. Also the study group was divided in to two groups according to insulin requirement. Type I is insulin-dependent diabetes mellitus and type II is non insulin-dependent diabetes mellitus. The study subjects selected for this study consist of one hundred Sudanese diabetic patients, they had mean age of 46.51±10.672 years, a mean height of 162.06±10.77 cm and a mean weight of 73.47±14.91 kg. Fifty healthy non-diabetic people without endocrine disease were chosen as controls. Glucose, and thyroid hormones, thyroxine and triiodothyronine (total T4 and T3) and thyroid stimulating hormone (TSH) were measured. In addition hemoglobin (Hb), total cholesterol (TC), triglyceride (TG), high-density lipoproteins (HDL) were also measured in both groups. Low-density lipoprotein (LDL) was calculated for each sample. Physical examinations such as height, weight, and history of diabetes, family history, treatment were recorded in both groups. Determination of serum hormones concentration was carried out using highly sensitive RIA technique. While determination of blood glucose, hemoglobin, and lipid profile was carried out using enzymatic colorimetric method. The results of this study showed that: 13 patients of the population screened had thyroid disease. The commonest diagnosis was sub clinical hyperthyroidism (6%), followed by sub clinical hypothyroidism (5%) and hyperthyroidism (2%). Female patients with diabetes had the highest annual risk of developing thyroid disease but all patient groups had a

  7. Combining insulins for optimal blood glucose control in type 1 and 2 diabetes: Focus on insulin glulisine

    OpenAIRE

    Ulrich, Heather; Snyder, Benjamin; K Garg, Satish

    2007-01-01

    Normalization of blood glucose is essential for the prevention of diabetes mellitus (DM)-related microvascular and macrovascular complications. Despite substantial literature to support the benefits of glucose lowering and clear treatment targets, glycemic control remains suboptimal for most people with DM in the United States. Pharmacokinetic limitations of conventional insulins have been a barrier to achieving treatment targets secondary to adverse effects such as hypoglycemia and weight ga...

  8. Effect of Punica granatum Linn. (flowers) on blood glucose level in normal and alloxan-induced diabetic rats.

    Science.gov (United States)

    Jafri, M A; Aslam, M; Javed, K; Singh, S

    2000-06-01

    'Gulnar farsi', male abortive flowers of Punica granatum L., are used for the treatment of diabetes mellitus in Unani medicine. Oral administration of its aqueous-ethanolic (50%, v/v) extract led to significant blood glucose lowering effect in normal, glucose-fed hyperglycaemic and alloxan-induced diabetic rats. This effect of the extract was maximum at 400 mg/kg, b.w. PMID:10837992

  9. Effects of telephone follow-up on blood glucose levels and postpartum screening in mothers with Gestational Diabetes Mellitus

    OpenAIRE

    Khorshidi Roozbahani, Rezvan; Geranmayeh, Mehrnaz; Hantoushzadeh, Sedigheh; Mehran, Abbas

    2015-01-01

    Background: Gestational diabetes mellitus (GDM) is a form of diabetes that occurs in pregnancy. GDM, defined as glucose intolerance, first diagnosed or initiated during pregnancy affects 1-14% of pregnancies based on various studies. Screening and early diagnosis and appropriate glycemic control can improve prenatal outcomes. Telephone follow-up seems to be a reasonable way for pregnant women follow-up. The present study evaluated the effects of telephone follow-up on blood glucose level duri...

  10. Effect of commercial rye whole-meal bread on postprandial blood glucose and gastric emptying in healthy subjects

    OpenAIRE

    Darwich Gassan; Björgell Ola; Lindstedt Sandra; Jönsson Jenny; Hlebowicz Joanna; Almér Lars-Olof

    2009-01-01

    Abstract Background The intake of dietary fibre has been shown to reduce the risk of developing diabetes mellitus. The aim of this study was to compare the effects of commercial rye whole-meal bread containing whole kernels and white wheat bread on the rate of gastric emptying and postprandial glucose response in healthy subjects. Methods Ten healthy subjects took part in a blinded crossover trial. Blood glucose level and gastric emptying rate (GER) were determined after the ingestion of 150 ...

  11. In-situ monitoring of blood glucose level for dialysis machine by AAA-battery-size ATR Fourier spectroscopy

    Science.gov (United States)

    Hosono, Satsuki; Sato, Shun; Ishida, Akane; Suzuki, Yo; Inohara, Daichi; Nogo, Kosuke; Abeygunawardhana, Pradeep K.; Suzuki, Satoru; Nishiyama, Akira; Wada, Kenji; Ishimaru, Ichiro

    2015-07-01

    For blood glucose level measurement of dialysis machines, we proposed AAA-battery-size ATR (Attenuated total reflection) Fourier spectroscopy in middle infrared light region. The proposed one-shot Fourier spectroscopic imaging is a near-common path and spatial phase-shift interferometer with high time resolution. Because numerous number of spectral data that is 60 (= camera frame rare e.g. 60[Hz]) multiplied by pixel number could be obtained in 1[sec.], statistical-averaging improvement realize high-accurate spectral measurement. We evaluated the quantitative accuracy of our proposed method for measuring glucose concentration in near-infrared light region with liquid cells. We confirmed that absorbance at 1600[nm] had high correlations with glucose concentrations (correlation coefficient: 0.92). But to measure whole-blood, complex light phenomenon caused from red blood cells, that is scattering and multiple reflection or so, deteriorate spectral data. Thus, we also proposed the ultrasound-assisted spectroscopic imaging that traps particles at standing-wave node. Thus, if ATR prism is oscillated mechanically, anti-node area is generated around evanescent light field on prism surface. By elimination complex light phenomenon of red blood cells, glucose concentration in whole-blood will be quantify with high accuracy. In this report, we successfully trapped red blood cells in normal saline solution with ultrasonic standing wave (frequency: 2[MHz]).

  12. Effect of extract of Abrus precatorius on blood glucose con-centration of alloxan induced diabetic Albino Wistar Rats

    Institute of Scientific and Technical Information of China (English)

    Georgewill OA; Georgewill UO

    2009-01-01

    Objective:To evaluate the effect of extract of Abrus precatorius on blood glucose of alloxan induced albino wist-ar rats.Methods:Experimental animals received daily oral administration of extract of Abrus precatorius for 14 days.The effect of 200 mg/kg dose was studied during the treatment period.Results:There was a significant reduction in blood glucose concentration (P <0.05)with the mean blood glucose of the different groups as 5.0 ±0.3 for normal control,7.0 ±0.4 for diabetic control group and 4.0 ±0.2 for diabetic treated group. Conclusion:The findings of this study suggest that extract of Abrus precatorius has hypoglycemic effect.

  13. Effect of Fasting Blood Glucose Level on Heart Rate Variability of Healthy Young Adults

    Science.gov (United States)

    Lutfi, Mohamed Faisal; Elhakeem, Ramaze Farouke

    2016-01-01

    Background Previous studies reported increased risk of cardiac events in subjects with fasting blood glucose (FBG) levels lower than the diagnostic threshold of diabetes mellitus. However, whether increased cardiac events in those with upper normal FBG is secondary to the shift of their cardiac sympathovagal balance towards sympathetic predominance is unknown. Aims To assess the association between FBG levels and cardiac autonomic modulation (CAM) in euglycaemic healthy subjects based on heart rate variability (HRV) derived indices. Subjects and Methods The study enrolled 42 healthy young adults. Following sociodemographic and clinical assessment, blood samples were collected to measure FBG levels. Five minutes ECG recordings were performed to all participants to obtain frequency domain HRV measurements, namely the natural logarithm (Ln) of total power (LnTP), very low frequency (LnVLF), low frequency (LnLF) and high frequency (LnHF), low frequency/ high frequency ratio (LnLF/HF), normalized low frequency (LF Norm) and high frequency (HF Norm). Results FBG levels correlated positively with LnHF (r = 0.33, P = 0.031) and HF Norm (r = 0.35, P = 0.025) and negatively with LF Norm (r = -0.35, P = 0.025) and LnLF/HF (r = -0.33, P = 0.035). LnHF and HF Norm were significantly decreased in subjects with the lower (4.00 (1.34) ms2/Hz and 33.12 (11.94) n.u) compared to those with the upper FBG quartile (5.64 (1.63) ms2/Hz and 49.43 (17.73) n.u, P = 0.013 and 0.032 respectively). LF Norm and LnLF/HF were significantly increased in subjects with the lower (66.88 (11.94) n.u and 0.73 (0.53)) compared to those with the higher FBG quartile (50.58 (17.83) n.u and 0.03 (0.79), P = 0.032 and 0.038 respectively). Conclusion The present study is the first to demonstrate that rise of blood glucose concentration, within physiological range, is associated with higher parasympathetic, but lower sympathetic CAM. Further researches are needed to set out the glycemic threshold beyond which

  14. Effect of Fasting Blood Glucose Level on Heart Rate Variability of Healthy Young Adults.

    Directory of Open Access Journals (Sweden)

    Mohamed Faisal Lutfi

    Full Text Available Previous studies reported increased risk of cardiac events in subjects with fasting blood glucose (FBG levels lower than the diagnostic threshold of diabetes mellitus. However, whether increased cardiac events in those with upper normal FBG is secondary to the shift of their cardiac sympathovagal balance towards sympathetic predominance is unknown.To assess the association between FBG levels and cardiac autonomic modulation (CAM in euglycaemic healthy subjects based on heart rate variability (HRV derived indices.The study enrolled 42 healthy young adults. Following sociodemographic and clinical assessment, blood samples were collected to measure FBG levels. Five minutes ECG recordings were performed to all participants to obtain frequency domain HRV measurements, namely the natural logarithm (Ln of total power (LnTP, very low frequency (LnVLF, low frequency (LnLF and high frequency (LnHF, low frequency/ high frequency ratio (LnLF/HF, normalized low frequency (LF Norm and high frequency (HF Norm.FBG levels correlated positively with LnHF (r = 0.33, P = 0.031 and HF Norm (r = 0.35, P = 0.025 and negatively with LF Norm (r = -0.35, P = 0.025 and LnLF/HF (r = -0.33, P = 0.035. LnHF and HF Norm were significantly decreased in subjects with the lower (4.00 (1.34 ms2/Hz and 33.12 (11.94 n.u compared to those with the upper FBG quartile (5.64 (1.63 ms2/Hz and 49.43 (17.73 n.u, P = 0.013 and 0.032 respectively. LF Norm and LnLF/HF were significantly increased in subjects with the lower (66.88 (11.94 n.u and 0.73 (0.53 compared to those with the higher FBG quartile (50.58 (17.83 n.u and 0.03 (0.79, P = 0.032 and 0.038 respectively.The present study is the first to demonstrate that rise of blood glucose concentration, within physiological range, is associated with higher parasympathetic, but lower sympathetic CAM. Further researches are needed to set out the glycemic threshold beyond which further increase in glucose level readjusts sympathovagal balance

  15. Testing the Role of Myeloid Cell Glucose Flux in Inflammation and Atherosclerosis

    Directory of Open Access Journals (Sweden)

    Tomohiro Nishizawa

    2014-04-01

    Full Text Available Inflammatory activation of myeloid cells is accompanied by increased glycolysis, which is required for the surge in cytokine production. Although in vitro studies suggest that increased macrophage glucose metabolism is sufficient for cytokine induction, the proinflammatory effects of increased myeloid cell glucose flux in vivo and the impact on atherosclerosis, a major complication of diabetes, are unknown. We therefore tested the hypothesis that increased glucose uptake in myeloid cells stimulates cytokine production and atherosclerosis. Overexpression of the glucose transporter GLUT1 in myeloid cells caused increased glycolysis and flux through the pentose phosphate pathway but did not induce cytokines. Moreover, myeloid-cell-specific overexpression of GLUT1 in LDL receptor-deficient mice was ineffective in promoting atherosclerosis. Thus, increased glucose flux is insufficient for inflammatory myeloid cell activation and atherogenesis. If glucose promotes atherosclerosis by increasing cellular glucose flux, myeloid cells do not appear to be the key targets.

  16. The effect of non-surgical periodontal therapy on systemic immune response and blood glucose level of NIDDM patients

    Directory of Open Access Journals (Sweden)

    Oedijani Santoso

    2008-03-01

    . Statistical analysis (t test were done using Stata 7.0 software, to compare the parameters before and after scaling in CDM and UCMD subjects. The results showed that scaling decreased IL-1β level and increased phagocytotic function significantly (P<0.05. Scaling decreased fasting and 2 hours post-prandial blood glucose levels and HbA1c level, but the decrease were not significant statistically (P>0.05, except for the decrease in HbA1c level in uncontrolled DM (P=0.00. (Med J Indones 2008; 17: 20-4Keywords : IL-1β level, phagocytotic function, HbA1C level

  17. Nanoscale Test Strips for Multiplexed Blood Analysis

    Science.gov (United States)

    Chan, Eugene

    2015-01-01

    A critical component of the DNA Medicine Institute's Reusable Handheld Electrolyte and Lab Technology for Humans (rHEALTH) sensor are nanoscale test strips, or nanostrips, that enable multiplexed blood analysis. Nanostrips are conceptually similar to the standard urinalysis test strip, but the strips are shrunk down a billionfold to the microscale. Each nanostrip can have several sensor pads that fluoresce in response to different targets in a sample. The strips carry identification tags that permit differentiation of a specific panel from hundreds of other nanostrip panels during a single measurement session. In Phase I of the project, the company fabricated, tested, and demonstrated functional parathyroid hormone and vitamin D nanostrips for bone metabolism, and thrombin aptamer and immunoglobulin G antibody nanostrips. In Phase II, numerous nanostrips were developed to address key space flight-based medical needs: assessment of bone metabolism, immune response, cardiac status, liver metabolism, and lipid profiles. This unique approach holds genuine promise for space-based portable biodiagnostics and for point-of-care (POC) health monitoring and diagnostics here on Earth.

  18. Comprehensive experiment-clinical biochemistry: determination of blood glucose and triglycerides in normal and diabetic rats.

    Science.gov (United States)

    Jiao, Li; Xiujuan, Shi; Juan, Wang; Song, Jia; Lei, Xu; Guotong, Xu; Lixia, Lu

    2015-01-01

    For second year medical students, we redesigned an original laboratory experiment and developed a combined research-teaching clinical biochemistry experiment. Using an established diabetic rat model to detect blood glucose and triglycerides, the students participate in the entire experimental process, which is not normally experienced during a standard clinical biochemistry exercise. The students are not only exposed to techniques and equipment but are also inspired to think more about the biochemical mechanisms of diseases. When linked with lecture topics about the metabolism of carbohydrates and lipids, the students obtain a better understanding of the relevance of abnormal metabolism in relation to diseases. Such understanding provides a solid foundation for the medical students' future research and for other clinical applications.

  19. Examining the causal association of fasting glucose with blood pressure in healthy children and adolescents

    DEFF Research Database (Denmark)

    Goharian, T S; Andersen, Lars Bo; Franks, P W;

    2015-01-01

    of this study could not support a causal association between FG and BP in healthy children and adolescents; however, it is possible that rs560887 has pleiotropic effects on unknown factors with a BP lowering effect or that these results were due to a lack of statistical power.Journal of Human Hypertension......The aim of the study was to determine whether genetically raised fasting glucose (FG) levels are associated with blood pressure (BP) in healthy children and adolescents. We used 11 common genetic variants of FG discovered in genome-wide association studies (GWAS), including the rs560887 single......-nucleotide polymorphism (SNP) located in the G6PC2 locus found to be robustly associated with FG in children and adolescents, as an instrument to associate FG with resting BP in 1506 children and adolescents from the European Youth Heart Study (EYHS). Rs560887 was associated with increased FG levels corresponding...

  20. Postprandial blood glucose control in type 1 diabetes for carbohydrates with varying glycemic index foods.

    Science.gov (United States)

    Hashimoto, Shogo; Noguchi, Claudia Cecilia Yamamoto; Furutani, Eiko

    2014-01-01

    Treatment of type 1 diabetes consists of maintaining postprandial normoglycemia using the correct prandial insulin dose according to food intake. Nonetheless, it is hardly achieved in practice, which results in several diabetes-related complications. In this study we present a feedforward plus feedback blood glucose control system that considers the glycemic index of foods. It consists of a preprandial insulin bolus whose optimal bolus dose and timing are stated as a minimization problem, which is followed by a postprandial closed-loop control based on model predictive control. Simulation results show that, for a representative carbohydrate intake of 50 g, the present control system is able to maintain postprandial glycemia below 140 mg/dL while preventing postprandial hypoglycemia as well. PMID:25571074

  1. Association between self-monitoring of blood glucose and diet among minority patients with diabetes*

    Science.gov (United States)

    McANDREW, Lisa M.; HOROWITZ, Carol R.; LANCASTER, Kristie J.; QUIGLEY, Karen S.; POGACH, Leonard M.; MORA, Pablo A.; LEVENTHAL, Howard

    2015-01-01

    Background Self-monitoring of blood glucose (SMBG) is used to regulate glucose control. It is unknown whether SMBG can motivate adherence to dietary recommendations. We predicted that participants who used more SMBG would also report lower fat and greater fruit and vegetable consumption. Methods The present study was a cross-sectional study of 401 primarily minority individuals living with diabetes in East Harlem, New York. Fat intake and fruit and vegetable consumption were measured with the Block Fruit/Vegetable/Fiber and Fat Screeners. Results Greater frequency of SMBG was associated with lower fat intake (rs = −0.15; P < 0.01), but not fruit and vegetable consumption. The effects of SMBG were not moderated by insulin use; thus, the relationship was significant for those individuals both on and not on insulin. A significant interaction was found between frequency of SMBG and changing one’s diet in response to SMBG on total fat intake. The data suggest that participants who use SMBG to guide their diet do not have to monitor multiple times a day to benefit. Conclusion The present study found that the frequency of SMBG was associated with lower fat intake. Patients are often taught to use SMBG to guide their self-management. This is one of the first studies to examine whether SMBG is associated with better dietary intake. PMID:21599868

  2. Effect of fructose or sucrose feeding with different levels on oral glucose tolerance test in normal and type 2 diabetic rats

    OpenAIRE

    Kwon, Sanghee; Kim, You Jin; Kim, Mi Kyung

    2008-01-01

    This study was designed to determine whether acute fructose or sucrose administration at different levels (0.05 g/kg, 0.1 g/kg or 0.4 g/kg body weight) might affect oral glucose tolerance test (OGTT) in normal and type 2 diabetic rats. In OGTT, there were no significant differences in glucose responses between acute fructose- and sucrose-administered groups. However, in normal rats, the AUCs of the blood glucose response for the fructose-administered groups tended to be lower than those of th...

  3. Effects of Gongronema latifolium on blood lipids, lipoproteins and glucose values in adult Nigerians

    Directory of Open Access Journals (Sweden)

    Rosemary Adamma Analike

    2015-04-01

    Full Text Available Background: The study evaluates the beneficial effects or otherwise of Gongronema latifolium (utazi consumption on plasma lipid profile and blood glucose in healthy subjects. Methods: The study was conducted on twenty (20 apparently healthy subjects (10 males and 10 females, within the age range of 20-55years who were randomly recruited from Nnamdi Azikiwe University Teaching Hospital (NAUTH staff and medical students in Nnewi Campus. Twenty experimental subjects (10 males and 10 females were fed with 5g/day of fresh Gongronema latifolium leaves for six weeks. Blood samples were collected at baseline and every week for six weeks and the biochemical parameters analyzed using standard laboratory methods. Results: There were significant reductions in the levels of plasma glucose (3.85 +/- 0.14 vs. 4.92 +/- 0.31 mmol/l, cholesterol (3.60 +/- 0.43 vs. 4.56 +/- 0.67 mmol/l, triglycerides (0.73 +/- 0.19 vs. 0.96 +/- 0.20 mmol/l, Low Density Lipoprotein Cholesterol (LDL-C (1.97 +/- 0.48 vs. 2.70 +/- 0.67 mmol/l and LDL-C/High Density Lipoprotein Cholesterol (HDL-C ratio (1.32 +/- 0.44 vs. 2.11 +/- 0.72 mmol/l of the subjects that were fed with Gongronema latifolium leaves for six weeks compared with their baseline values; all P <0.05. Conclusion: The result of this study showed that Gongronema latifolium has hypoglycemic and hypolipidemic effect on healthy subjects and might be beneficial for the management of diabetes mellitus and cardiovascular diseases. [Int J Res Med Sci 2015; 3(4.000: 891-895

  4. Effects of Flavonoids in Morus indica on Blood Lipids and Glucose in Hyperlipidemia-diabetic Rats

    Institute of Scientific and Technical Information of China (English)

    MA Dong-qing; JIANG Zheng-ju; XU Shi-qiang; YU Xing; HU Xia-min; PAN Hong-yan

    2012-01-01

    Objective To investigate the effect and possible mechanism of flavonoids extracted from Morus indica(FMI)on blood lipids and glucose.Methods The experimental hyperlipidemia-diabetic rats were induced by high-fat diet(HFD)and low dose of Streptozotocin(STZ).Flavonoids-treated rats were pretreated with FMI(50,100,and 200 mg/kg).The plasma,skeletal muscle,and livers were isolated for biochemical assays,HE staining,immunohistochemistry,and Western blotting analysis.Results The results showed that the body weight in flavonoidstreated(100 and 200 mg/kg)rats was reduced(P<0.05,0.01)compared to HFD-fed rats.FMI obviously reduced total cholesterol(P<0.01),triglycerides(P<0.05),and low-density lipoprotein cholesterol(P<0.05),increased high-density lipoprotein(P<0.05),and significantly decreased the atherosclerosis index(P<0.01);FMI(100 and 200 mg/kg)also down-regulated the elevation of blood glucose induced by STZ(P<0.05,0.01);At the meantime,FMI increased hepatic superoxide dismutase(SOD)activity and reduced hepatic malondialdehyde(MDA)content obviously.In addition,the results showed that the expression of hepatic CYP2E1 was markedly decreased while the expression of GLUT-4 in skeletal muscles was increased by FMI.Conclusion The above results demonstrate that the effect of FMI is related to its up-regulation of hepatic SOD activity,reduction of hepatic MDA content,down-regulation of hepatic CYP2E1 expression,and increase of GLUT-4 expression in skeletal muscle,which suggests that FMI may prevent or improve hyperlipidemia and hyperglycemia caused by an excessive HFD.

  5. Blood glucose control in patients with severe sepsis and septic shock

    Institute of Scientific and Technical Information of China (English)

    Hiroyuki Hirasawa; Shigeto Oda; Masataka Nakamura

    2009-01-01

    The main pathophysiological feature of sepsis is the uncontrollable activation of both pro- and anti-inflammatory responses arising from the overwhelming production of mediators such as pro- and anti-inflammatory cytokines. Such an uncontrollable inflammatory response would cause many kinds of metabolic derangements.One such metabolic derangement is hyperglycemia.Accordingly, control of hyperglycemia in sepsis is considered to be a very effective therapeutic approach. However, despite the initial enthusiasm, recent studies reported that tight glycemic control with intensive insulin therapy failed to show a beneficial effect on mortality of patients with severe sepsis and septic shock. One of the main reasons for this disappointing result is the incidence of harmful hypoglycemia during intensive insulin therapy. Therefore, avoidance of hypoglycemia during intensive insulin therapy may be a key issue in effective tight glycemic control.It is generally accepted that glycemic control aimed at a blood glucose level of 80-100 mg/dL, as initially proposed by van den Berghe, seems to be too tight and that such a level of tight glycemic control puts septic patients at increased risk of hypoglycemia. Therefore,now many researchers suggest less strict glycemic control with a target blood glucose level of 140-180 mg/dL.Also specific targeting of glycemic control in diabetic patients should be considered. Since there is a significant correlation between success rate of glycemic control and the degree of hypercytokinemia in septic patients,some countermeasures to hypercytokinemia may be an important aspect of successful glycemic control. Thus,in future, use of an artificial pancreas to avoid hypoglycemia during insulin therapy, special consideration of septic diabetic patients, and control of hypercytokinemia should be considered for more effective glycemic control in patients with severe sepsis and septic shock.

  6. Study of the Effect of Garlic on Serum Lipids and Blood Glucose Levels in Type 2 Diabetic Patients

    Directory of Open Access Journals (Sweden)

    M Afkhami - Ardekani

    2005-04-01

    Full Text Available Introduction: Hyperlipidemia and diabetes are common risk factors for ischemic heart disease, which is the main cause of mortality in diabetic patients. Strict control of blood glucose and other risk factors in diabetics has led to prevention of complications. Garlic has received particular attention for control of blood glucose and decrease in blood lipid levels. At present, several studies have been carried out in order to prove advantages of garlic. Methods: In this study, effects of garsin (a derivative of garlic present in our country on serum lipids and blood glucose levels in diabetes mellitus type 2 patients was observed. Forty-five type 2 diabetics who had hyperlipidemia were selected. These patients were kept on treatment with 3 tablets of Garsin / day for 4 weeks. Serum lipids and blood glucose levels were measured prior to and at the end of treatment. Results: Relationship between sex and response to treatment in this study was meaningful, such that Gsarsin led to decrease in LDL-C and increase in HDL in females. Conclusion: Therefore, Garsin can be used as an adjunct to treatment in diabetes type 2 patients with hyperlipidemia.

  7. The impact of brief high-intensity exercise on blood glucose levels

    Directory of Open Access Journals (Sweden)

    Adams OP

    2013-02-01

    Full Text Available O Peter AdamsFaculty of Medical Sciences, the University of the West Indies, Cave Hill Campus, St Michael, BarbadosBackground: Moderate-intensity exercise improves blood glucose (BG, but most people fail to achieve the required exercise volume. High-intensity exercise (HIE protocols vary. Maximal cycle ergometer sprint interval training typically requires only 2.5 minutes of HIE and a total training time commitment (including rest and warm up of 25 minutes per session. The effect of brief high-intensity exercise on blood glucose levels of people with and without diabetes is reviewed.Methods: HIE (≥80% maximal oxygen uptake, VO2max studies with ≤15 minutes HIE per session were reviewed.Results: Six studies of nondiabetics (51 males, 14 females requiring 7.5 to 20 minutes/week of HIE are reviewed. Two weeks of sprint interval training increased insulin sensitivity up to 3 days postintervention. Twelve weeks near maximal interval running (total exercise time 40 minutes/week improved BG to a similar extent as running at 65% VO2max for 150 minutes/week. Eight studies of diabetics (41 type 1 and 22 type 2 subjects were reviewed. Six were of a single exercise session with 44 seconds to 13 minutes of HIE, and the others were 2 and 7 weeks duration with 20 and 2 minutes/week HIE, respectively. With type 1 and 2 diabetes, BG was generally higher during and up to 2 hours after HIE compared to controls. With type 1 diabetics, BG decreased from midnight to 6 AM following HIE the previous morning. With type 2 diabetes, a single session improved postprandial BG for 24 hours, while a 2-week program reduced the average BG by 13% at 48 to 72 hours after exercise and also increased GLUT4 by 369%.Conclusion: Very brief HIE improves BG 1 to 3 days postexercise in both diabetics and nondiabetics. HIE is unlikely to cause hypoglycemia during and immediately after exercise. Larger and longer randomized studies are needed to determine the safety, acceptability, long

  8. Blood glucose and plasma insulin responses to fat-free milk and low-lactose fat-free milk in young type 1 diabetics.

    Science.gov (United States)

    Wright, J; Marks, V; Salminen, S

    1987-12-01

    The blood glucose and plasma insulin responses to test milk samples were studied in eight insulin-dependent diabetics. After an overnight fast, the subjects (aged 20-45 years) were given a breakfast containing two Weetabix biscuits (20 g carbohydrate) with 500 ml of either regular (S) fat-free milk (25 g lactose) or 500 ml of a new low-lactose (D) fat-free milk (3.75 g lactose and 4.25 g fructose). The regular morning insulin dose was omitted. Mean basal plasma glucose level was slightly higher before S milk (11.4 vs. 10.1 mmol/l). The peak increment in plasma glucose was higher in S milk (9.4 vs. 6.6 mmol/l). The rise was 83% above basal (S) vs. 65% (D). Although the final mean plasma glucose concentration was not significantly higher 3 h after S milk compared with D milk (17.9 vs. 14.3 mmol/l) the incremental area under the plasma glucose curve was much greater (p less than 0.001) with S milk than with D milk (1266 +/- 295 units vs. 909 +/- 242 units). No galactose was detectable in any sample and there was no difference in plasma beta-hydroxybutyrate levels. The results suggest that the low-lactose fat-free milk (D) may be suitable for diabetic diets and weight reducing diets due to the lower contribution of energy. The results suggest that fat-free milk does not exert a fast action on blood glucose concentration and therefore fat-free milk and especially low-lactose fat-free milk may also prove to be suitable for diabetic diets.

  9. Direct measurements of blood glucose concentration in the presence of saccharide interferences using slope and bias orthogonal signal correction and Fourier transform near-infrared spectroscopy.

    Science.gov (United States)

    Abookasis, David; Workman, Jerome J

    2011-02-01

    Saccharide interferences such as Dextran, Galactose, etc. have a great potential to interfere with near infrared (NIR) glucose analysis since they have a similar spectroscopic fingerprint and are present physiologically at large relative concentrations. These can lead to grossly inappropriate interpretation of patient glucose levels and resultant treatment in critical care and hospital settings. This study describes a methodology to reduce this effect on glucose analysis using an NIR Fourier transform spectroscopy method combined with a multivariate calibration technique (PLS) using preprocessing by orthogonal signal correction (OSC). A mathematical approach based on the use of a single calibration based bias and slope correction was applied in addition to a standard OSC was investigated. This approach is combined with a factorial interferent calibration design to accommodate for interference effects. We named this approach as a slope and bias OSC (sbOSC). sbOSC differs from OSC in the way it handles the prediction. In sbOSC, statistics on slope and bias obtained from a set of calibration samples are then used as a validation parameter in the prediction set. Healthy human volunteer blood with different glucose (80 to 200 mg/dL) and hematocrit (24 to 48 vol.%) levels containing high expected levels of inteferents have been measured with a transmittance near-infrared Fourier transform spectrometer operates in the broadband spectral range of 1.25-2.5 μm (4000-8000 cm(-1)). The effect of six interferents compounds used in intensive care and operating rooms, namely Dextran, Fructose, Galactose, Maltose, Mannitol, and Xylose, were tested on blood glucose. A maximum interference effect (MIE) parameter was used to rank the significance for the individual interferent type on measurement error relative to the total NIR whole blood glucose measurement error. For comparison, a YSI (Yellow Springs Instrument) laboratory reference glucose analyzer and NIR data were collected at

  10. The Effect of Trans-Chalcone on Amylase Activity, Blood Glucose and Lipid Levels in Diabetic and Non Diabetic Rats

    OpenAIRE

    Najafian, M.; Ebrahim-Habibi, A.; P Yaghmaei; Parivar, K.; Larijani, B.

    2011-01-01

    Introduction & Objective: Alpha amylase is the most important decomposing enzyme in starch. Digestion and absorption of starch in the intestine can be prevented and also the blood sugar levels can be controlled by restrain and control of alpha amylase. The aim of this study was to evaluate the effect of trans-chalcone on amylase activity, blood glucose and lipid levels in diabetic and non diabetic rats. Materials & Methods: This experimental study was conducted in 1388 at Tehran Universit...

  11. Effect of n-3 fatty acid supplementation on blood glucose, lipid profile and cytokines in humans: A pilot study

    OpenAIRE

    Raghu, B.; Venkatesan, P

    2008-01-01

    This study was undertaken to evaluate the effects of n-3 fatty acid supplementation on blood glucose, lipid profile and cytokines in humans. Twenty adult healthy subjects were supplemented with 1g/day fish oil concentrate capsules for 2 weeks. Fasting blood samples were taken at baseline and again after 2 week intervention. Fish oil supplementation significantly lowered fasting serum concentrations of total cholesterol, triacylglycerol, very low density lipoprotein and low density lipoprotein...

  12. Clinical significance of serum carbohydrate antigen 19-9 and its relationship with blood glucose in patients with type 2 diabetes

    Institute of Scientific and Technical Information of China (English)

    武秀玲

    2013-01-01

    Objective To study the relationship between serum carbohydrate antigen 19-9 (CA19-9) and blood glucose level in patients with type 2 diabetes (T2DM) .Methods Totally 784 T2DM patients and 197 healthy controls were enrolled in this study.Age,duration,body mass index (BMI) ,systolic blood pressure (SBP) ,diastolic blood pressure (DBP) ,levels of fasting blood glucose (FBG) ,postprandial blood glucose (PBG) ,hemoglobin A1c (HbA1c) ,total cholesterol (TC) ,triglyceride (TG) ,

  13. Cardiovascular responses to the ingestion of sugary drinks using a randomised cross-over study design: Does glucose attenuate the blood pressure-elevating effect of fructose?

    Science.gov (United States)

    Grasser, Erik K; Dulloo, Abdul; Montani, Jean-Pierre

    2014-07-28

    Overconsumption of sugar-sweetened beverages has been implicated in the pathogenesis of CVD. The objective of the present study was to elucidate acute haemodynamic and microcirculatory responses to the ingestion of sugary drinks made from sucrose, glucose or fructose at concentrations similar to those often found in commercial soft drinks. In a randomised cross-over study design, twelve young healthy human subjects (seven men) ingested 500 ml tap water in which was dissolved 60 g of either sucrose, glucose or fructose, or an amount of fructose equivalent to that present in sucrose (i.e. 30 g fructose). Continuous cardiovascular monitoring was performed for 30 min before and at 60 min after ingestion of sugary drinks, and measurements included beat-to-beat blood pressure (BP) and impedance cardiography. Additionally, microvascular endothelial function testing was performed after iontophoresis of acetylcholine and sodium nitroprusside using laser Doppler flowmetry. Ingestion of fructose (60 or 30 g) increased diastolic and mean BP to a greater extent than the ingestion of 60 g of either glucose or sucrose (Psugary drinks. In conclusion, ingestion of fructose, but not sucrose, increases BP in healthy human subjects. Although sucrose comprises glucose and fructose, its changes in TPR and CO are more related to glucose than to fructose.

  14. Cardiovascular responses to the ingestion of sugary drinks using a randomised cross-over study design: Does glucose attenuate the blood pressure-elevating effect of fructose?

    Science.gov (United States)

    Grasser, Erik K; Dulloo, Abdul; Montani, Jean-Pierre

    2014-07-28

    Overconsumption of sugar-sweetened beverages has been implicated in the pathogenesis of CVD. The objective of the present study was to elucidate acute haemodynamic and microcirculatory responses to the ingestion of sugary drinks made from sucrose, glucose or fructose at concentrations similar to those often found in commercial soft drinks. In a randomised cross-over study design, twelve young healthy human subjects (seven men) ingested 500 ml tap water in which was dissolved 60 g of either sucrose, glucose or fructose, or an amount of fructose equivalent to that present in sucrose (i.e. 30 g fructose). Continuous cardiovascular monitoring was performed for 30 min before and at 60 min after ingestion of sugary drinks, and measurements included beat-to-beat blood pressure (BP) and impedance cardiography. Additionally, microvascular endothelial function testing was performed after iontophoresis of acetylcholine and sodium nitroprusside using laser Doppler flowmetry. Ingestion of fructose (60 or 30 g) increased diastolic and mean BP to a greater extent than the ingestion of 60 g of either glucose or sucrose (Psugary drinks. In conclusion, ingestion of fructose, but not sucrose, increases BP in healthy human subjects. Although sucrose comprises glucose and fructose, its changes in TPR and CO are more related to glucose than to fructose. PMID:24780643

  15. A Soxhlet Extract of Gongronema latifolium Retains Moderate Blood Glucose Lowering Effect and Produces Structural Recovery in the Pancreas of STZ-Induced Diabetic Rats

    Directory of Open Access Journals (Sweden)

    Bassel Al-Hindi

    2016-04-01

    Full Text Available Background: Gongronema latifolium Benth. (GL possesses considerable glucose lowering effects able to be utilized on a large-scale. This paper investigates the effects of a Soxhlet extract on hyperglycemia, Langerhans islets and glucose uptake by abdominal muscles. Methods: Ethanol and a Soxhlet apparatus were used to obtain GL ethanolic Soxhlet extract (GLES. It was then administered to randomly-segregated male Sprague-Dawley, normal and STZ-induced diabetic rats, using oral gavage to evaluate blood glucose levels (BGLs, serum lipid profile, insulin levels and the pancreas post-treatment. Results: GLES significantly (p < 0.05 decreased BGLs of normal rats in glucose tolerance testing at a dose of 2 g/kg b.w. but failed to do so in diabetic rats undergoing acute 7-h treatment. Given twice-daily, 1 g/kg b.w. of GLES moderately controlled diabetic BGLs starting from day 10. After 14 days of treatment, 1 g/kg and 0.5 g/kg b.w. of GLES caused 44% and 50% respective increases in the average area of Langerhans islets compared to DC. Using isolated rat abdominal muscle, GLES was found to be a mild insulin-sensitizer. GC-MS analysis revealed the presence of the known glucose-lowering phytosterol, Sitostenone. Conclusion: Despite retaining moderate antidiabetic activity, Soxhlet extraction of Gongronema latifolium probably leads to the destruction of active heat-liable compounds.

  16. DEVELOPMENT OF A WEARABLE GLUCOSE SENSOR - STUDIES IN HEALTHY-VOLUNTEERS AND IN DIABETIC-PATIENTS

    NARCIS (Netherlands)

    AALDERS, AL; SCHMIDT, FJ; SCHOONEN, AJM; BROEK, IR; MAESSEN, AGFM; DOORENBOS, H

    1991-01-01

    A glucose sensor with a subcutaneous dialysis system was tested in six healthy volunteers during an oral glucose tolerance test and in ten diabetic patients with hyperglycemia during rapid decline of blood glucose levels. There was a good correlation between sensor and blood glucose values. During o

  17. Caffeine modifies blood glucose availability during prolonged low-intensity exercise in individuals with type-2 diabetes

    Directory of Open Access Journals (Sweden)

    Luiz Augusto da Silva

    2014-07-01

    Full Text Available Objective: The study investigated the effect of supplementation with maltodextrin (CHO alone or associated to caffeine during exercise in T2DM subjects.Methods: Pilot study, using Eight subjects with T2DM, aged 55±10 years, received CHO (1g/kg or caffeine (1.5 mg/kg alone or associated before exercise protocol. The exercise was executed at 40% heart rate (HR reserve for 40 min, with 10-min recovery. Blood pressure (BP and perceived exertion scale (Borg were checked every 2 min. Blood glucose (BG was checked every 10 min. For statistical analysis, ANOVA test was used and the value was considered statistically significant at p <0.05.Results: The results showed that BP and HR did not change significantly among all treatments. Caffeine promoted a significant reduction in BG of 75 mg/dL (65%, p <0.05 during 40 min of exercise protocol compared to all groups.Conclusion: Supplementation with 1.5 mg/kg of caffeine reduces BG concentration during prolonged exercise in T2DM patients.

  18. A moderate elevation of blood glucose level increases the effectiveness of thermoradiotherapy in a rat tumor model I. relative contributions of glucose and heating to tumor acidification

    International Nuclear Information System (INIS)

    Purpose: To establish dose-effect relationships for tumor acidification induced by heat and glucose as a basis for testing the value of adding glucose administration to combined heat and x-ray treatment at clinically achievable glucose and temperature levels. Methods and Materials: Rhabdomyosarcoma BA1112 was grown s.c. in the upper leg of 16-20-week-old Wag/Rij rats. Animals were given 2 consecutive 100-min periods of saline (S) or glucose (G) infusion, while keeping tumor temperature at 37 deg., 42 deg., or 43 deg. C for 1 or 2 periods, in various combinations, each involving 6 animals. Glucose was infused i.v. as a 20% solution at 2.4-3 g/kg/h. Tumors were heated using 2,450-MHz electromagnetic radiation, and tumor pH was measured using a 0.7 mm fiberoptic probe. Results: Mean overall baseline pH was 7.00 (SD 0.10). The change induced by G37G43 (i.e., glucose infusion for a full 200 min, first 100 min at 37 deg. C, final 100 min at 43 deg. C) was -0.48±0.03 (SEM) pH units, and -0.17 ± 0.03 for S37S43. The effect of G37G42 was -0.37±0.03 pH units, compared with -0.08±0.02 for S37S42 and -0.28±0.04 for glucose alone (G37G37). Glucose was less effective when given after or fully parallel to heating: -0.21±0.02 pH units for S43G37 and -0.37±0.02 for G43G43. Conclusion: The glucose-induced tumor pH drop is much more pronounced than that induced by heat, both of which are dose dependent. The effects of glucose and heat seem additive if heating is started when glucose-induced acidification has reached its plateau level, but the overall effect is diminished if administration is fully simultaneous or in reversed order. Schedule G37G43 is optimal with respect to tumor acidification. Its predicted superiority in thermoradiotherapy as compared with S37S42, S37S43, and G37G42 treatment regimens was confirmed in a subsequent experimental tumor control study

  19. Hollow optical-fiber based infrared spectroscopy for measurement of blood glucose level by using multi-reflection prism.

    Science.gov (United States)

    Kino, Saiko; Omori, Suguru; Katagiri, Takashi; Matsuura, Yuji

    2016-02-01

    A mid-infrared attenuated total reflection (ATR) spectroscopy system employing hollow optical fibers and a trapezoidal multi-reflection ATR prism has been developed to measure blood glucose levels. Using a multi-reflection prism brought about higher sensitivity, and the flat and wide contact surface of the prism resulted in higher measurement reproducibility. An analysis of in vivo measurements of human inner lip mucosa revealed clear signatures of glucose in the difference spectra between ones taken during the fasting state and ones taken after ingestion of glucose solutions. A calibration plot based on the absorption peak at 1155 cm(-1) that originates from the pyranose ring structure of glucose gave measurement errors less than 20%. PMID:26977373

  20. Hollow optical-fiber based infrared spectroscopy for measurement of blood glucose level by using multi-reflection prism.

    Science.gov (United States)

    Kino, Saiko; Omori, Suguru; Katagiri, Takashi; Matsuura, Yuji

    2016-02-01

    A mid-infrared attenuated total reflection (ATR) spectroscopy system employing hollow optical fibers and a trapezoidal multi-reflection ATR prism has been developed to measure blood glucose levels. Using a multi-reflection prism brought about higher sensitivity, and the flat and wide contact surface of the prism resulted in higher measurement reproducibility. An analysis of in vivo measurements of human inner lip mucosa revealed clear signatures of glucose in the difference spectra between ones taken during the fasting state and ones taken after ingestion of glucose solutions. A calibration plot based on the absorption peak at 1155 cm(-1) that originates from the pyranose ring structure of glucose gave measurement errors less than 20%.

  1. Short-Term High-Intensity Interval Training on Body Composition and Blood Glucose in Overweight and Obese Young Women

    Science.gov (United States)

    Kong, Zhaowei; Sun, Shengyan; Liu, Min

    2016-01-01

    This study was to determine the effects of five-week high-intensity interval training (HIIT) on cardiorespiratory fitness, body composition, blood glucose, and relevant systemic hormones when compared to moderate-intensity continuous training (MICT) in overweight and obese young women. Methods. Eighteen subjects completed 20 sessions of HIIT or MICT for five weeks. HIIT involved 60 × 8 s cycling at ~90% of peak oxygen consumption (V˙O2peak) interspersed with 12 s recovery, whereas MICT involved 40-minute continuous cycling at 65% of V˙O2peak. V˙O2peak, body composition, blood glucose, and fasting serum hormones, including leptin, growth hormone, testosterone, cortisol, and fibroblast growth factor 21, were measured before and after training. Results. Both exercise groups achieved significant improvements in V˙O2peak (+7.9% in HIIT versus +11.7% in MICT) and peak power output (+13.8% in HIIT versus +21.9% in MICT) despite no training effects on body composition or the relevant systemic hormones. Blood glucose tended to be decreased after the intervention (p = 0.062). The rating of perceived exertion in MICT was higher than that in HIIT (p = 0.042). Conclusion. Compared with MICT, short-term HIIT is more time-efficient and is perceived as being easier for improving cardiorespiratory fitness and fasting blood glucose for overweight and obese young women.

  2. Effects of L-lysine monohydrochloride on insulin and blood glucose levels in spinal cord injured rats

    Institute of Scientific and Technical Information of China (English)

    ZHANG Tian-ling; ZHAO Yu-wu; LIU Xue-yuan; DING Su-ju

    2010-01-01

    Background Hyperglycemia in brain and spinal cord could aggravate neurologic impairment. Recent studies showed that L-lysine monohydrochlonde (LMH) could increase the insulin secretion and regulate the blood glucose level. The aim of the present study was to investigate the effects of LMH on pancreatic islet B cells, the levels of endogenous insulin and blood glucose in spinal cord injured rats.Methods Forty male Wistar rats were divided into four groups, namely, normal control group, model group, high-dose LMH group (621.5 mg/kg equal to LMH 1/8 LD50), and low-dose LMH group (310.8 mg/kg equal to LMH 1/16 LD50). The model of spinal cord injured rat was established by hemi-transection at the lower right thoracic spinal cord. LMH was administered via intraperitoneal injection once spinal cord injury was produced in rats. All rats were sacrificed 48 hours after spinal cord injured. The effects of LMH on pancreatic islet B cells, the content of endogenous insulin, end the level of blood glucose were observed with immunohistochemical method, radioimmunoassay method, end biochemical analyzer, respectively. Results The insulin immunohistochemical intensities of islet B cells were significantly weaker in model group then those in normal control group (P 0.05). Conclusion LMH, but dose-dependent, might participate in the regulation of pancreatic islet B cells, and then reduce the blood glucose levels in the spinal cord injured rats.

  3. Laboratory Exercise: Study of Digestive and Regulatory Processes through the Exploration of Fasted and Postprandial Blood Glucose

    Science.gov (United States)

    Hopper, Mari K.; Maurer, Luke W.

    2013-01-01

    Digestive physiology laboratory exercises often explore the regulation of enzyme action rather than systems physiology. This laboratory exercise provides a systems approach to digestive and regulatory processes through the exploration of postprandial blood glucose levels. In the present exercise, students enrolled in an undergraduate animal…

  4. Effect of nondigestible oligosaccharides on large-bowel functions, blood lipid concentrations and glucose absorption in young healthy male subjects

    NARCIS (Netherlands)

    Dokkum, W. van; Wezendonk, B.; Srikumar, T.S.; Heuvel, E.G.H.M. van den

    1999-01-01

    Objective: To study the effect of the intake of 15 g nondigestible oligosaccharides per day on various parameters of large-bowel function, as well as on blood lipid concentrations and glucose absorption in man. Design: Latin square, randomized, double-blind, diet-controlled. Setting: Metabolic resea

  5. Reliability of point-of-care hematocrit, blood gas, electrolyte, lactate and glucose measurement during cardiopulmonary bypass.

    NARCIS (Netherlands)

    Steinfelder-Visscher, J.; Weerwind, P.W.; Teerenstra, S.; Brouwer, M.H.J.

    2006-01-01

    BACKGROUND: Recently, the GEM Premier blood gas analyser was upgraded to the GEM Premier 3000. In addition to pH, pCO2, pO2, Na+, K+, Ca2+, and hematocrit measurement, glucose and lactate can be measured on the GEM Premier 3000. In this prospective clinical study, the analytical performance of the G

  6. [The net analyte preprocessing combined with radial basis partial least squares regression applied in noninvasive measurement of blood glucose].

    Science.gov (United States)

    Li, Qing-Bo; Huang, Zheng-Wei

    2014-02-01

    In order to improve the prediction accuracy of quantitative analysis model in the near-infrared spectroscopy of blood glucose, this paper, by combining net analyte preprocessing (NAP) algorithm and radial basis functions partial least squares (RBFPLS) regression, builds a nonlinear model building method which is suitable for glucose measurement of human, named as NAP-RBFPLS. First, NAP is used to pre-process the near-infrared spectroscopy of blood glucose, in order to effectively extract the information which only relates to glucose signal from the original near-infrared spectra, so that it could effectively weaken the occasional correlation problems of the glucose changes and the interference factors which are caused by the absorption of water, albumin, hemoglobin, fat and other components of the blood in human body, the change of temperature of human body, the drift of measuring instruments, the changes of measuring environment, and the changes of measuring conditions; and then a nonlinear quantitative analysis model is built with the near-infrared spectroscopy data after NAP, in order to solve the nonlinear relationship between glucose concentrations and near-infrared spectroscopy which is caused by body strong scattering. In this paper, the new method is compared with other three quantitative analysis models building on partial least squares (PLS), net analyte preprocessing partial least squares (NAP-PLS) and RBFPLS respectively. At last, the experimental results show that the nonlinear calibration model, developed by combining NAP algorithm and RBFPLS regression, which was put forward in this paper, greatly improves the prediction accuracy of prediction sets, and what has been proved in this paper is that the nonlinear model building method will produce practical applications for the research of non-invasive detection techniques on human glucose concentrations.

  7. GIT (Glucose Infusion Test): polycentric evaluation of a new test for vascular access recirculation.

    Science.gov (United States)

    Alloatti, S; Magnasco, A; Bonfant, G; Bonello, F; Ciciani, A M; Fidelio, T; Filiberti, O; Forneris, G; Martina, G; Robaudo, C; Romano, U; Schelotto, C

    2000-01-01

    Introduction. Vascular access recirculation (AR), which is often unacknowledged, remains an important cause of inadequate dialytic dose. The glucose infusion test (GIT) is a new method for detecting and quantifying AR. This paper reports on a polycentric evaluation of the new test and a comparison with the classical Urea-test (UT). Methods. GIT protocol comprises withdrawal from the arterial port (sample A), injection into the venous drip chamber of 1 g glucose in 4 seconds, withdrawal from the arterial port (sample B) continuously from 13 to 17 seconds. Glucose is determined on A and B by a reflectance photometer. If B = A then there is no recirculation. If B exceeds A by at least 20 mg/dl there is recirculation. AR quantification: AR% = (B-A) / 20. GIT was performed on 623 patients from eleven dialysis centers to screen the patients for AR. Subsequently, GIT and Urea-test (UT) were compared in 189 paired tests. The reproducibility of GIT and UT was studied in 28 paired tests performed in sequence. Results. The screening test by GIT was positive in 68 cases (11 %). The majority of positivities was found in central venous catheters (CVC, 27/50 cases, 54 %), whereas only 7 % of artero-venous fistulas (AVF) were positive. In the CVC group, Tesio catheters were more frequently positive compared to Dual Lumen Catheters (64 % vs. 29 %). The comparison GIT - UT showed that results matched in 162 tests (79 negative and 83 positive both by GIT and UT), showing that on the grounds of UT, GIT has high sensitivity and specificity. In 27 tests GIT was positive, but UT negative. This disagreement is due to the different minimal limit of detection, 1 % for GIT and 5% for UT. The reproducibility was greater with GIT than with UT with a lower D% (respectively -0.6 +/- 2.5 and -0.4 +/- 6.1 %, p<0.001) and a lower coefficient of variation (17 vs 33 %). Conclusions. The screening of 623 patients by GIT confirmed that AR in AVF is normally absent, whereas an un-expectedly high

  8. Effects of short term changes in the blood glucose level on the autofluorescence lifetime of the human retina in healthy volunteers

    Science.gov (United States)

    Klemm, Matthias; Nagel, Edgar; Schweitzer, Dietrich; Schramm, Stefan; Haueisen, Jens

    2016-03-01

    Purpose: Fluorescence lifetime imaging ophthalmoscopy (FLIO) provides in vivo metabolic mapping of the ocular fundus. Changes in FLIO have been found in e.g. diabetes patients. The influence of short term metabolic changes caused by blood glucose level changes on is unknown. Aim of this work is the detection of short-term changes in fundus autofluorescence lifetime during an oral glucose tolerance test. Methods: FLIO was performed in 10 healthy volunteers (29+/-4 years, fasting for 12h) using a scanning laser ophthalmoscope (30° fundus, 34μm resolution, excitation with 473nm diode laser with 70 ps pulses at 80 MHz repetition rate, detection in two spectral channels 500-560nm (ch1) and 560-720nm (ch2) using the timecorrelated single photon counting method). The blood glucose level (BGL) was measured by an Accu-Chek® Aviva self-monitoring device. Before and after a glucose drink (300ml solution, containing 75g of glucose (Accu-Chek® Dextrose O.G.T.), BGL and FLIO were measured every 15min. The FLIMX software package was applied to compute the average fluorescence lifetime τ on the inner ring of the ETDRS grid using a modified 3-exponential approach. Results: The results are given as mean +/- standard deviation over all volunteers in ch1. Baseline measurement: BGL: 5.3+/-0.4 mmol/l, τ1: 49+/-6ps. A significant reduction (α=5% Wilcoxon rank-sum test) in τ1 is detected after 15min (BGL: 8.4+/-1.1 mmol/l, τ1: 44+/-5ps) and after 90min (BGL: 6.3+/-1.4 mmol/l, τ1: 41+/-5ps). Results of ch2 show smaller reductions in the fluorescence lifetimes over time.

  9. EVALUATION OF THE EFFECT OF âWAKOUBA '' ON THE LIPID PROFILE, SYSTOLIC BLOOD PRESSURE (SBP) DIASTOLIC (DBP) AND BLOOD GLUCOSE IN HYPERTENSIVE RABBITS

    OpenAIRE

    Tiekpa Wawa J; Bahi C; N’guessan J.D; Koutou A

    2014-01-01

    This study aims at evaluating the effects of Wakouba, an extract of the fronds of oil palm tree Elaeis guineensis (Jacq) traditionally used in the treatment of high blood pressure, on lipid profile, urea, creatinine, blood glucose, systolic blood pressure (SBP), diastolic (DBP) and heart rate (HR) in hypertensive rabbits. Methods: Twenty four rabbits (24) divided into six (06) groups of four rabbits each weighing between 1.5 ±3.0 to 2± 1.5 kg were used. Group 1 served as witness, group 2 sick...

  10. Review of Blood Glucose Detective Methods%血糖检测方法的研究现状

    Institute of Scientific and Technical Information of China (English)

    王阳; 张松; 杨琳

    2011-01-01

    The control of the blood glucose is an important way for understanding pathogenic condition and evaluating treatment effects of mellitus diabetes. In this paper, the invasive, minimally invasive and non-invasive blood glucose detecting techniques in clinic are summarized respectively. Advantages and disadvantages of these techniques are compared and analyzed from the technical aspect. The technical principles of the current blood glucose monitoring instruments are analyzed. Non-invasive detection methods and their development foreground are specially introduced. Although there are many types of non-invasive blood glucose detectors, there is a lack of a non-invasive, continuous, dynamic, accurate, good- repeatability product, which can be widely used in home health care, and replace the traditional invasive blood glucose detector. At present, every one of the invasive, minimally invasive or non-invasive blood glucose detecting technique has its characteristic, can not be substituted each other. The non-invasive technique is the future of blood glucose detector, which still needs studied in a multi-interdisciplinary subject.%掌握血糖的变化是了解糖尿病病情和评价治疗效果的重要途径.本文从有创、微创和无创三个方面对血糖检测方法及存在问题进行了陈述;从技术方面对目前的血糖仪进行分析,着重介绍了无创检测方式的原理及发展前景.虽然无创血糖检测方法很多,但目前仍然缺乏一种无创伤、连续、动态、准确、重复性良好的方法,使之能够广泛应用于家庭保健,并取代传统的有创血糖检测仪.有创、微创、无创血糖检测方法目前各有优劣,尚无法相互取代,而无创血糖检测是未来血糖检测技术发展的方向,有待于多学科的综合研究.

  11. What is the optimal blood glucose target in critically ill patients? A nested cohort study

    Directory of Open Access Journals (Sweden)

    Ashraf Al-Tarifi

    2011-01-01

    Full Text Available Aims: There is an uncertainty about what constitutes an optimal level of blood glucose (BG in critically ill patients. The objective of this study is to identify the optimal BG target for glycemic control in critically ill patients that is associated with survival benefit with the least hypoglycemia risk. Setting and Design: This is a nested cohort study within a randomized control trial conducted in a tertiary care center in King Abdulaziz Medical City, Riyadh, Kingdom of Saudi Arabia. Methods: The study was carried out in a single center to assess the effect of intensive insulin therapy [IIT; target BG 4.4-6.1 mmol/L (80-110 mg/dL] versus conventional insulin therapy [CIT; target BG 10-11.1 mmol/L (180-200 mg/dL] in a medical/surgical ICU. All patients were divided into six groups based on the mean daily BG levels. A logistic regression model was used to determine the association of BG and ICU mortality. We compared different outcomes below and above different BG thresholds of 0.1 mmol/L (2 mg/dL increments using multivariate analyses. Statistical Analysis: Data are presented as mean ± SD or median with interquartile ranges, unless otherwise indicated. Differences between the six groups were assessed using the c΂ test. A P-value equal or less than 0.05 was considered to indicate statistical significance. The results were expressed as adjusted odds ratio (aOR and 95% confidence intervals (CI. Statistical analyses were carried out using the Statistical Analysis Software (SAS, release 8, SAS Institute Inc., Cary, NC, USA. Results: Among six groups, the ICU mortality was least in patients with BG <8.7 mmol/L (<157 mg/dL compared with patients with BG ≥8.7 mmol/L (≥157 mg/dL [11.5% vs. 21.5%, P = 0.002]. When analyzed using 0.1 mmol increments in average BG, we found that mortality remained unchanged by increasing thresholds of BG up to 8.0 mmol/L (144 mg/dL and started to rise with thresholds of BG of 8.1 mmol/L (146 mg/dL and above. The

  12. Bio-enhancing effect of Piperine with Metformin on lowering blood glucose level in Alloxan induced diabetic mice

    Directory of Open Access Journals (Sweden)

    Shubham Atal

    2016-01-01

    Full Text Available Background: Diabetes mellitus is the most rampant metabolic pandemic of the 21 st century. Piperine, the chief alkaloid of Piper nigrum (black pepper is widely used in alternative and complementary therapies has been extensively studied for its bio-enhancing property. Objective: To evaluate the bio-enhancing effect of piperine with metformin in lowering blood glucose levels in alloxan-induced diabetic mice. Materials and Methods: Piperine was isolated from an extract of fruits of P. nigrum. Alloxan-induced (150 mg/kg intraperitoneal diabetic mice were divided into four groups. Group I (control 2% gum acacia 2 g/100 mL, Group II (metformin 250 mg/kg, Group III (metformin and piperine 250 mg/kg + 10 mg/kg, and Group IV (metformin and piperine 125 mg/kg + 10 mg/kg. All the drugs were administered orally once daily for 28 days. Blood glucose levels were estimated at day 0, day 14, and end of the study (day 28. Results: The combination of piperine with therapeutic dose of metformin (10 mg/kg + 250 mg/kg showed significantly more lowering of blood glucose level as compared to metformin alone on both 14 th and 28 th day (P < 0.05. Piperine in combination with sub-therapeutic dose of metformin (10 mg/kg + 125 mg/kg showed significantly more lowering of blood glucose as compared to control group and also showed greater lowering of blood glucose as compared to metformin (250 mg/kg alone. Conclusion: Piperine has the potential to be used as a bio-enhancing agent in combination with metformin which can help reduce the dose of metformin and its adverse effects.

  13. Effects of exposure to electromagnetic field radiation (EMFR generated by activated mobile phones on fasting blood glucose

    Directory of Open Access Journals (Sweden)

    Sultan Ayoub Meo

    2013-04-01

    Full Text Available Objective: Extensive use of mobile phones has been accompanied by a common public debate about possible adverse effects on human health. No study has been published so far to establish any association between the fastest growing innovation of mobile phone and fasting blood glucose. The aim was to determine the effects of exposure to electromagnetic field radiation generated by mobile phones on fasting blood glucose in Wistar Albino rats. Materials and Methods: 40 Male Albino rats (Wistar Strain were divided into 5 equally numerous groups. Group A served as the control one, group B received mobile phone radiation for less than 15 min/day, group C: 15-30 min/day, group D: 31-45 min/day, and group E: 46-60 min/day for a total period of 3 months. Fasting blood glucose was determined by using Spectrophotometer and serum insulin by Enzyme-linked Immunosorbent Assay (ELISA. The Homeostatic Model (HOMA-B was applied for the assessment of β-cell function and (HOMA-IR for resistance to insulin. Results: Wister Albino rats exposed to mobile phone radiation for longer than 15 min a day for a total period of 3 months had significantly higher fasting blood glucose (p < 0.015 and serum insulin (p < 0.01 compared to the control group. HOMA-IR for insulin resistance was significantly increased (p < 0.003 in the groups that were exposed for 15-30 and 46-60 min/day compared to the control rats. Conclusion: The results of the present study show an association between long-term exposure to activated mobile phones and increase in fasting blood glucose and serum insulin in Albino rats.

  14. Physical Activity, Blood Glucose and C-Peptide in Healthy School-Children, a Longitudinal Study.

    Directory of Open Access Journals (Sweden)

    Karina Huus

    Full Text Available To further elucidate the relationship between physical activity and several risk factors for development of diabetes (glucose, C-peptide and obesity over time.A prospective longitudinal study where physical activity was measured on 199 children from Kalmar and Linköping at age 8, and the same 107 children from Linköping again at age 12. Anthropometric data was collected and blood was analyzed for C-peptide and f-glucose. The children in the study were representative for the general Swedish child population, and on an average lean.High physical activity was related to lower C-peptide at age 8 and 12. This correlation was especially pronounced in boys, who also were more physically active than girls at both time points. The association seen at 8 years of age was similar at age 12 in most children. Children with higher BMI Z-Score had a higher fasting C-peptide (age 12 but linear regression showed that children with more steps per day were less likely to have a higher fasting C-peptide irrespective of BMI. Longitudinal follow-up showed that a decrease in physical activity increased insulin resistance and β-cell load.Already in young children, physical activity improves insulin sensitivity and decreases the need of C-peptide over time. This seems to become even more pronounced with increasing age when children are followed longitudinally. Low physical activity increases the load on insulin producing β-cells, might increase the risk for both type 1- and 2 diabetes.

  15. Addition of sitagliptin or metformin to insulin monotherapy improves blood glucose control via different effects on insulin and glucagon secretion in hyperglycemic Japanese patients with type 2 diabetes.

    Science.gov (United States)

    Otsuka, Yuichiro; Yamaguchi, Suguru; Furukawa, Asami; Kosuda, Minami; Nakazaki, Mitsuhiro; Ishihara, Hisamitsu

    2015-01-01

    This study aimed to explore the effects of the dipeptidyl peptidase-4 inhibitor sitagliptin and the biguanide metformin on the secretion of insulin and glucagon, as well as incretin levels, in Japanese subjects with type 2 diabetes mellitus poorly controlled with insulin monotherapy. This was a single-center, randomized, open-label, parallel group study, enrolling 25 subjects. Eleven patients (hemoglobin A1c [HbA1c] 8.40 ± 0.96%) and 10 patients (8.10 ± 0.54%) on insulin monotherapy completed 12-week treatment with sitagliptin (50 mg) and metformin (750 mg), respectively. Before and after treatment, each subject underwent a meal tolerance test. The plasma glucose, glucagon-like peptide-1 (GLP-1), glucose-dependent insulinotropic polypeptide (GIP), C-peptide, and glucagon responses to a meal challenge were measured. HbA1c reductions were similar in patients treated with sitagliptin (0.76 ± 0.18%) and metformin (0.77 ± 0.17%). In the sitagliptin group, glucose excursion during a meal tolerance test was reduced and accompanied by elevations in active GLP-1 and active GIP concentrations. C-peptide levels were unaltered despite reduced glucose responses, while glucagon responses were significantly suppressed (-7.93 ± 1.95% of baseline). In the metformin group, glucose excursion and incretin responses were unaltered. C-peptide levels were slightly increased but glucagon responses were unchanged. Our data indicate that sitagliptin and metformin exert different effects on islet hormone secretion in Japanese type 2 diabetic patients on insulin monotherapy. A glucagon suppressing effect of sitagliptin could be one of the factors improving blood glucose control in patients inadequately controlled with insulin therapy. PMID:25328079

  16. ACUTE EFFECT OF FLUCONAZOLE, ITRACONAZOLE AND VORICONAZOLE ON BLOOD GLUCOSE IN NORMOGLYCEAMIC & DIABETIC RATS: AN EXPERIMENTAL STUDY

    Directory of Open Access Journals (Sweden)

    Jadhav Amol, Nayak BB, Vakade Kiran P, Sanghishetti Vijay Prasad, Vijay Kumar AN, Vrushali Nibrad, Raul AR

    2015-01-01

    Full Text Available Anti-fungal and antimicrobials are frequently co-prescribed either to manage or treat either the secondary complications or other diseases. Among antifungal drugs Fluconazole, Itraconazole & Voriconazole are most commonly used. The present study was undertaken to further confirm the effect of Voriconazole as well as other antifungal drugs on blood Glucose level. Aim & Objectives: 1. To Study the effect of Fluconazole, Itraconazole & Voriaconazole in Normoglycemic & Diabetic Rats on Blood Glucose. 2. To compare the effects between all drugs. Material & Methodology: Grouping: Animals divided into 8 groups in each group 6 animals. Group 1- 4: Normoglycemic rats, Group 5-8 Diabetic rats (alloxan induced Group 1,5: received vehicle (Normal saline Group 2,6: received Fluconazole (18mg/kg BW, Group 3,7 received Itraconazole (18mg/kg BW Group 4,8 received Voriconazole (18mg/kg BW. The glucose levels were estimated by Glucometer method (Accu-check active at the interval of 0, ½ hr, 1hrs, 2hrs & 4hrs after drug administration. Results: Effect on blood glucose in Normoglycemic Rats: Voriconazole had a significant hypoglycaemic effect which appeared after 1 hr (‘p’ value= 0.0102 of administration & persisted up to 2 hrs (‘p’ value=0.0001. However effect of Voriconzole was found to be declined after 2 hrs. There was no significant change in blood glucose in normoglycemic rats with Fluconazole & Itraconazole. Effect on blood glucose in Diabetic Rats: (Table 2: Voriconazole had a significant hypoglycaemic effect which appeared after 1 hr (‘p’ value=0.013 of administration & persisted up to 2 hrs (‘p’ value=0.001 in acute studies. However effect of Voriconzole was found to be declined after 2 hrs. There was no significant change in blood glucose in diabetic rats with Fluconazole & Itraconazole treated. Conclusion: Itraconazole, Fluconazole can be safely used in diabetic with fungal infections. Voriconazole should be avoided in diabetics to

  17. Growth hormone suppression test

    Science.gov (United States)

    GH suppression test; Glucose loading test; Acromegaly - blood test; Gigantism - blood test ... during the suppression test, the provider will suspect gigantism or acromegaly. You may need to be retested to confirm ...

  18. Intensive blood glucose control and vascular outcomes in patients with type 2 diabetes

    NARCIS (Netherlands)

    Patel, A.; MacMahon, S.; Chalmers, J.; Neal, B.; Billot, L.; Woodward, M.; Marre, M.; Cooper, M.; Glasziou, P.; Grobbee, D.; Hamet, P.; Harrap, S.; Heller, S.; Liu, L.; Mancia, G.; Mogensen, C.E.; Pan, C.; Poulter, N.; Rodgers, A.; Williams, B.; Bompoint, S.; Galan, B.E. de; Joshi, R.; Travert, F.

    2008-01-01

    BACKGROUND: In patients with type 2 diabetes, the effects of intensive glucose control on vascular outcomes remain uncertain. METHODS: We randomly assigned 11,140 patients with type 2 diabetes to undergo either standard glucose control or intensive glucose control, defined as the use of gliclazide (

  19. Glucose supplementation has minimal effects on blood neutrophil functionand gene expression in vitro

    Science.gov (United States)

    During early lactation, glucose availability is low and the effect of glucose supply on bovine polymorphonuclear leukocyte (PMNL) function is poorly understood. The objective of this study was to determine the effect of glucose supplementation on the function and transcriptomic inflammatory respons...

  20. Seventy-five gram glucose tolerance test to assess carbohydrate malabsorption and small bowel bacterial overgrowth

    OpenAIRE

    URITA, Yoshihisa; Ishihara, Susumu; Akimoto, Tatsuo; Kato, Hiroto; HARA, Noriko; Honda, Yoshiko; Nagai, Yoko; Nakanishi, Kazushige; Shimada, Nagato; Sugimoto, Motonobu; Miki, Kazumasa

    2006-01-01

    AIM: To investigate non-invasively the incidence of absorption of carbohydrates in diabetic patients during an oral glucose tolerance test (OGTT) and to determine whether malabsorption may be associated with insulin secretion and insulin resistance.