WorldWideScience

Sample records for blood count

  1. Low White Blood Cell Count

    Science.gov (United States)

    Symptoms Low white blood cell count By Mayo Clinic Staff A low white blood cell count (leukopenia) is a decrease ... of white blood cell (neutrophil). The definition of low white blood cell count varies from one medical ...

  2. Complete Blood Count (For Parents)

    Science.gov (United States)

    ... Kids Deal With Injections and Blood Tests Blood Culture Anemia Blood Test: Basic Metabolic Panel (BMP) Blood Test: Hemoglobin Basic Blood Chemistry Tests Word! Complete Blood Count (CBC) Medical Tests and Procedures ( ...

  3. Low white blood cell count and cancer

    Science.gov (United States)

    ... gov/ency/patientinstructions/000675.htm Low white blood cell count and cancer To use the sharing features on this page, please enable JavaScript. White blood cells (WBCs) fight infections from bacteria, viruses, fungi, and ...

  4. White Blood Cell Counts and Malaria

    National Research Council Canada - National Science Library

    McKenzie, F. E; Prudhomme, Wendy A; Magill, Alan J; Forney, J. R; Permpanich, Barnyen; Lucas, Carmen; Gasser, Jr., Robert A; Wongsrichanalai, Chansuda

    2005-01-01

    White blood cells (WBCs) were counted in 4697 individuals who presented to outpatient malaria clinics in Maesod, Tak Province, Thailand, and Iquitos, Peru, between 28 May and 28 August 1998 and between 17 May and 9 July 1999...

  5. Blood Count Tests: MedlinePlus Health Topic

    Science.gov (United States)

    ... Spanish WBC count (Medical Encyclopedia) Also in Spanish Topic Image MedlinePlus Email Updates Get Blood Count Tests ... WBC count Show More Show Less Related Health Topics Bleeding Disorders Blood Laboratory Tests National Institutes of ...

  6. Red Blood Cell Count Automation Using Microscopic Hyperspectral Imaging Technology.

    Science.gov (United States)

    Li, Qingli; Zhou, Mei; Liu, Hongying; Wang, Yiting; Guo, Fangmin

    2015-12-01

    Red blood cell counts have been proven to be one of the most frequently performed blood tests and are valuable for early diagnosis of some diseases. This paper describes an automated red blood cell counting method based on microscopic hyperspectral imaging technology. Unlike the light microscopy-based red blood count methods, a combined spatial and spectral algorithm is proposed to identify red blood cells by integrating active contour models and automated two-dimensional k-means with spectral angle mapper algorithm. Experimental results show that the proposed algorithm has better performance than spatial based algorithm because the new algorithm can jointly use the spatial and spectral information of blood cells.

  7. Microfluidic Cytometer for Complete Blood Count Analysis, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — RMD proposes to develop a MEMS based complete blood count (CBC) instrument that can be used aboard a spacecraft. We will produce a microfluidic scale combination...

  8. Microfluidic Cytometer for Complete Blood Count Analysis, Phase II

    Data.gov (United States)

    National Aeronautics and Space Administration — We will fabricate and test microfluidic designs for a micro-electromechanical system based complete blood count (CBC) analysis in separate modules and integrate them...

  9. White blood cell count - series (image)

    Science.gov (United States)

    ... the hand. The puncture site is cleaned with antiseptic, and a tourniquet (an elastic band) or blood ... or young child: The area is cleansed with antiseptic and punctured with a sharp needle or a ...

  10. The counting of native blood cells by digital microscopy

    Science.gov (United States)

    Torbin, S. O.; Doubrovski, V. A.; Zabenkov, I. V.; Tsareva, O. E.

    2017-03-01

    An algorithm for photographic images processing of blood samples in its native state was developed to determine the concentration of erythrocytes, leukocytes and platelets without individual separate preparation of cells' samples. Special "photo templates" were suggested to use in order to identify red blood cells. The effect of "highlighting" of leukocytes, which was found by authors, was used to increase the accuracy of this type of cells counting. Finally to raise the resolution of platelets from leukocytes the areas of their photo images were used, but not their sizes. It is shown that the accuracy of cells counting for native blood samples may be comparable with the accuracy of similar studies for smears. At the same time the proposed native blood analysis simplifies greatly the procedure of sample preparation in comparison to smear, permits to move from the detection of blood cells ratio to the determination of their concentrations in the sample.

  11. The Full blood count and blood film (Haemogram)

    African Journals Online (AJOL)

    the possible results and what decisions might those results lead us to make?” Then we should ask ... iron (reduced), transferrin (reduced) and ferritin (normal or raised). There is no .... ('gingerbread men') on the blood film. malignant disease.

  12. Diagnostic value of inflammatory markers (complete blood count ...

    African Journals Online (AJOL)

    Objective The aim of the study was to evaluate the diagnostic value of inflammatory markers [complete blood cell count (CBC), erythrocyte sedimentation rate (ESR), C-reactive protein (CRP)] for the differentiation of acute appendicitis from nonspecific abdominal pain in children. Patients and methods In this prospective ...

  13. Diagnostic value of inflammatory markers (complete blood count ...

    African Journals Online (AJOL)

    Objective The aim of the study was to evaluate the diagnostic value of inflammatory markers [complete blood cell count (CBC), erythrocyte sedimentation rate (ESR),. C-reactive protein (CRP)] for the differentiation of acute appendicitis from nonspecific abdominal pain in children. Patients and methods In this prospective ...

  14. Nutritionally-related blood metabolites and faecal egg counts in ...

    African Journals Online (AJOL)

    Nutritionally-related blood metabolites and faecal egg counts in indigenous Nguni goats of South Africa. ... It, therefore, is imperative to put measures in place to counteract the drop in any of these parameters, with season, if productivity of the indigenous goats is to be maintained. Further studies are required to determine the ...

  15. 21 CFR 864.6160 - Manual blood cell counting device.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Manual blood cell counting device. 864.6160 Section 864.6160 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES HEMATOLOGY AND PATHOLOGY DEVICES Manual Hematology Devices § 864.6160 Manual...

  16. Cord blood full blood count parameters in Lagos, Nigeria | Adewumi ...

    African Journals Online (AJOL)

    Due to its usefulness in the assessment of health status of individuals, its parameters in cord blood, a major source of haemopoietic stem cell transplantation and an ideal source for laboratory investigations for newborns were determined to provide a useful guide to local neonatologists and stem cell transplant physicians.

  17. Identification and red blood cell automated counting from blood smear images using computer-aided system.

    Science.gov (United States)

    Acharya, Vasundhara; Kumar, Preetham

    2018-03-01

    Red blood cell count plays a vital role in identifying the overall health of the patient. Hospitals use the hemocytometer to count the blood cells. Conventional method of placing the smear under microscope and counting the cells manually lead to erroneous results, and medical laboratory technicians are put under stress. A computer-aided system will help to attain precise results in less amount of time. This research work proposes an image-processing technique for counting the number of red blood cells. It aims to examine and process the blood smear image, in order to support the counting of red blood cells and identify the number of normal and abnormal cells in the image automatically. K-medoids algorithm which is robust to external noise is used to extract the WBCs from the image. Granulometric analysis is used to separate the red blood cells from the white blood cells. The red blood cells obtained are counted using the labeling algorithm and circular Hough transform. The radius range for the circle-drawing algorithm is estimated by computing the distance of the pixels from the boundary which automates the entire algorithm. A comparison is done between the counts obtained using the labeling algorithm and circular Hough transform. Results of the work showed that circular Hough transform was more accurate in counting the red blood cells than the labeling algorithm as it was successful in identifying even the overlapping cells. The work also intends to compare the results of cell count done using the proposed methodology and manual approach. The work is designed to address all the drawbacks of the previous research work. The research work can be extended to extract various texture and shape features of abnormal cells identified so that diseases like anemia of inflammation and chronic disease can be detected at the earliest.

  18. Complete Blood Count Reference Intervals for Healthy Han Chinese Adults

    Science.gov (United States)

    Mu, Runqing; Guo, Wei; Qiao, Rui; Chen, Wenxiang; Jiang, Hong; Ma, Yueyun; Shang, Hong

    2015-01-01

    Background Complete blood count (CBC) reference intervals are important to diagnose diseases, screen blood donors, and assess overall health. However, current reference intervals established by older instruments and technologies and those from American and European populations are not suitable for Chinese samples due to ethnic, dietary, and lifestyle differences. The aim of this multicenter collaborative study was to establish CBC reference intervals for healthy Han Chinese adults. Methods A total of 4,642 healthy individuals (2,136 males and 2,506 females) were recruited from six clinical centers in China (Shenyang, Beijing, Shanghai, Guangzhou, Chengdu, and Xi’an). Blood samples collected in K2EDTA anticoagulant tubes were analyzed. Analysis of variance was performed to determine differences in consensus intervals according to the use of data from the combined sample and selected samples. Results Median and mean platelet counts from the Chengdu center were significantly lower than those from other centers. Red blood cell count (RBC), hemoglobin (HGB), and hematocrit (HCT) values were higher in males than in females at all ages. Other CBC parameters showed no significant instrument-, region-, age-, or sex-dependent difference. Thalassemia carriers were found to affect the lower or upper limit of different RBC profiles. Conclusion We were able to establish consensus intervals for CBC parameters in healthy Han Chinese adults. RBC, HGB, and HCT intervals were established for each sex. The reference interval for platelets for the Chengdu center should be established independently. PMID:25769040

  19. Association of Blood Eosinophil and Blood Neutrophil Counts with Asthma Exacerbations in the Copenhagen General Population Study

    DEFF Research Database (Denmark)

    Vedel-Krogh, Signe; Nielsen, Sune Fallgaard; Lange, Peter

    2017-01-01

    BACKGROUND: Blood eosinophil count is a marker of eosinophilic airway inflammation and disease severity in asthma. However, blood neutrophil count might also be associated with disease severity. We tested the hypothesis that high blood eosinophil and neutrophil counts are both associated...... with the risk of asthma exacerbations among individuals with asthma from the general population. METHODS: From the Copenhagen General Population Study with 81351 participants, we included 4838 with self-reported asthma. We recorded baseline blood eosinophil and neutrophil counts, and asthma exacerbations during...... with blood eosinophil counts >0.29 × 10(9)/L (highest tertile) vs individuals with blood eosinophil counts

  20. Is automated platelet counting still a problem in thrombocytopenic blood?

    Directory of Open Access Journals (Sweden)

    Raimundo Antônio Gomes Oliveira

    Full Text Available CONTEXT: Reliable platelet counting is crucial for indicating prophylactic platelet transfusion in thrombocytopenic patients. OBJECTIVE: To evaluate the precision and accuracy of platelet counting for thrombocytopenic patients, using four different automated counters in comparison with the Brecher & Cronkite reference method recommended by the International Committee for Standardization in Hematology (ICSH. TYPE OF STUDY: Automated platelet counting assessment in thrombocytopenic patients. SETTING: Hematology Laboratory, Hospital do Servidor Público Estadual de São Paulo, and the Hematology Division of Instituto Adolfo Lutz, São Paulo, SP, Brazil. MAIN MEASUREMENTS: Brecher & Cronkite reference method and four different automated platelet counters. PARTICIPANTS: 43 thrombocytopenic patients with platelet counts of less than 30,000/µl RESULTS: The ADVIA-120 (Bayer, Coulter STKS, H1 System (Technicom-Bayer and Coulter T-890 automatic instruments presented great precision and accuracy in relation to laboratory thrombocytopenic samples obtained by diluting blood from normal donors. However, when thrombocytopenic patients were investigated, all the counters except ADVIA (which is based on volume and refraction index showed low accuracy when compared to the Brecher & Cronkite reference method (ICSH. The ADVIA counter showed high correlation (r = 0.947. However, all counters showed flags in thrombocytopenic samples. CONCLUSION: The Brecher & Cronkite reference method should always be indicated in thrombocytopenic patients for platelet counts below 30,000 plt /µl obtained in one dimensional counters.

  1. Peak-counts blood flow model-errors and limitations

    International Nuclear Information System (INIS)

    Mullani, N.A.; Marani, S.K.; Ekas, R.D.; Gould, K.L.

    1984-01-01

    The peak-counts model has several advantages, but its use may be limited due to the condition that the venous egress may not be negligible at the time of peak-counts. Consequently, blood flow measurements by the peak-counts model will depend on the bolus size, bolus duration, and the minimum transit time of the bolus through the region of interest. The effect of bolus size on the measurement of extraction fraction and blood flow was evaluated by injecting 1 to 30ml of rubidium chloride in the femoral vein of a dog and measuring the myocardial activity with a beta probe over the heart. Regional blood flow measurements were not found to vary with bolus sizes up to 30ml. The effect of bolus duration was studied by injecting a 10cc bolus of tracer at different speeds in the femoral vein of a dog. All intravenous injections undergo a broadening of the bolus duration due to the transit time of the tracer through the lungs and the heart. This transit time was found to range from 4-6 second FWHM and dominates the duration of the bolus to the myocardium for up to 3 second injections. A computer simulation has been carried out in which the different parameters of delay time, extraction fraction, and bolus duration can be changed to assess the errors in the peak-counts model. The results of the simulations show that the error will be greatest for short transit time delays and for low extraction fractions

  2. Absolute counting of neutrophils in whole blood using flow cytometry.

    Science.gov (United States)

    Brunck, Marion E G; Andersen, Stacey B; Timmins, Nicholas E; Osborne, Geoffrey W; Nielsen, Lars K

    2014-12-01

    Absolute neutrophil count (ANC) is used clinically to monitor physiological dysfunctions such as myelosuppression or infection. In the research laboratory, ANC is a valuable measure to monitor the evolution of a wide range of disease states in disease models. Flow cytometry (FCM) is a fast, widely used approach to confidently identify thousands of cells within minutes. FCM can be optimised for absolute counting using spiked-in beads or by measuring the sample volume analysed. Here we combine the 1A8 antibody, specific for the mouse granulocyte protein Ly6G, with flow cytometric counting in straightforward FCM assays for mouse ANC, easily implementable in the research laboratory. Volumetric and Trucount™ bead assays were optimized for mouse neutrophils, and ANC values obtained with these protocols were compared to ANC measured by a dual-platform assay using the Orphee Mythic 18 veterinary haematology analyser. The single platform assays were more precise with decreased intra-assay variability compared with ANC obtained using the dual protocol. Defining ANC based on Ly6G expression produces a 15% higher estimate than the dual protocol. Allowing for this difference in ANC definition, the flow cytometry counting assays using Ly6G can be used reliably in the research laboratory to quantify mouse ANC from a small volume of blood. We demonstrate the utility of the volumetric protocol in a time-course study of chemotherapy induced neutropenia using four drug regimens. © 2014 International Society for Advancement of Cytometry.

  3. White blood cell counting analysis of blood smear images using various segmentation strategies

    Science.gov (United States)

    Safuan, Syadia Nabilah Mohd; Tomari, Razali; Zakaria, Wan Nurshazwani Wan; Othman, Nurmiza

    2017-09-01

    In white blood cell (WBC) diagnosis, the most crucial measurement parameter is the WBC counting. Such information is widely used to evaluate the effectiveness of cancer therapy and to diagnose several hidden infection within human body. The current practice of manual WBC counting is laborious and a very subjective assessment which leads to the invention of computer aided system (CAS) with rigorous image processing solution. In the CAS counting work, segmentation is the crucial step to ensure the accuracy of the counted cell. The optimal segmentation strategy that can work under various blood smeared image acquisition conditions is remain a great challenge. In this paper, a comparison between different segmentation methods based on color space analysis to get the best counting outcome is elaborated. Initially, color space correction is applied to the original blood smeared image to standardize the image color intensity level. Next, white blood cell segmentation is performed by using combination of several color analysis subtraction which are RGB, CMYK and HSV, and Otsu thresholding. Noises and unwanted regions that present after the segmentation process is eliminated by applying a combination of morphological and Connected Component Labelling (CCL) filter. Eventually, Circle Hough Transform (CHT) method is applied to the segmented image to estimate the number of WBC including the one under the clump region. From the experiment, it is found that G-S yields the best performance.

  4. Ancestry informative markers and complete blood count parameters in Brazilian blood donors

    Directory of Open Access Journals (Sweden)

    Gabriela E. S. Felix

    Full Text Available A complete blood count is very useful in clinical diagnoses when reference ranges are well established for the population. Complete blood counts and allele frequencies of Ancestry Informative Markers (AIMs were analyzed in Brazilians with the aim of characterizing the hematological values of an admixed population. Positive associations were observed between gender and neutrophils, monocytes, eosinophils, erythrocytes, hemoglobin, hematocrit, MCV, MCHC and platelet counts. No significant differences were found for age, alcohol consumption, educational status, ethnicity, smoking in respect to the complete blood count values. In general, men had higher red blood cell values, while women had higher values for white blood cells and platelets. The study of the population was highly heterogeneous with mean proportions (± SE of African, European and Amerindian ancestry being 49.0 ± 3.0%, 44.0 ± 9.0% and 7.0 ± 9.0%, respectively. Amerindian ancestry showed limited contribution to the makeup of the population, but estimated ancestral proportions were statistically significant (r = 0.9838; P<0.001. These hematologic values are similar to Afro-Americans, another admixed population.

  5. [Complete blood count reference values of donated cord blood from Korean neonates].

    Science.gov (United States)

    Lee, Hye Ryun; Shin, Sue; Yoon, Jong Hyun; Kim, Byoung Jae; Hwang, Kyu Ri; Kim, Jin Ju; Roh, Eun Youn

    2009-06-01

    In the public cord blood (CB) banks, only safe CB units with adequate cell doses are processed and stored. Complete blood count (CBC) of CB is crucial for estimating total nucleated cells (TNC) and screening suitable CB units without hematologic abnormalities. We analyzed CBC parameters of the donated CB from healthy Korean neonates to establish CBC reference values. A total of 2,129 Korean CB units, donated and processed during the period from August 2007 to December 2007, were enrolled. We measured hemoglobin (Hb), white blood cell (WBC) count, differential count of WBC, platelets and nucleated red blood cell (nRBC) count by XE-2100 automated hematology analyzer (Sysmex, Japan), and estimated reference value of each parameter by using parametric (Mean+/-2SD) and/or non-parametric methods (2.5-97.5 percentile). And also, we compared the result of each parameter in relation to sex of neonates and delivery method. Because the differences of CBC values among different subgroups were not remarkable, we established the reference intervals as follows without subgroup division: Hb, 9.0-14.4 g/dL; WBC count, 5.6-18.5 x 10(3)/microL; differential count of WBC (neutrophils, 40.8-72.4%; lymphocytes, 17.2-46.7%; monocytes, 4.9-12.8%; eosinophils, 0.7-7.0%; basophils, 0.0-1.6%); platelet, 130-287 x 10(3)/microL; nRBCs, 0.0-13.1/100 WBC. We established cord blood CBC reference values of healthy Korean neonates using a large-scale CB units. The established CBC reference values from our study will be useful as basic data for CBC interpretation and assessment of transplant suitability of donated CB.

  6. Relationship of blood and milk cell counts with mastitic pathogens in Murrah buffaloes

    Directory of Open Access Journals (Sweden)

    C. Singh

    2010-02-01

    Full Text Available The present study was undertaken to see the effect of mastitic pathogens on the blood and milk counts of Murrah buffaloes. Milk and blood samples were collected from 9 mastitic Murrah buffaloes. The total leucocyte Counts (TLC and Differential leucocyte counts (DLC in blood were within normal range and there was a non-significant change in blood counts irrespective of different mastitic pathogens. Normal milk quarter samples had significantly (P<0.01 less Somatic cell counts (SCC. Lymphocytes were significantly higher in normal milk samples, whereas infected samples had a significant increase (P<0.01 in milk neutrophils. S. aureus infected buffaloes had maximum milk SCC, followed by E. coli and S. agalactiae. Influx of neutrophils in the buffalo mammary gland was maximum for S. agalactiae, followed by E.cli and S. aureus. The study indicated that level of mastitis had no affect on blood counts but it influenced the milk SCC of normal quarters.

  7. Determination of blood cell subtype concentrations from frozen whole blood samples using TruCount beads.

    Science.gov (United States)

    Langenskiöld, Cecilia; Mellgren, Karin; Abrahamsson, Jonas; Bemark, Mats

    2016-06-24

    In many studies it would be advantageous if blood samples could be collected and analyzed using flow cytometry at a later stage. Ideally, sample collection should involve little hands-on time, allow for long-term storage, and minimally influence the samples. Here we establish a flow cytometry antibody panel that can be used to determine granulocytes, monocytes, and lymphocyte subset concentrations in fresh and frozen whole blood using TruCount technology. The panel can be used on fresh whole-blood samples as well as whole-blood samples that have been frozen after mixing with 10% DMSO. Concentrations in frozen and fresh sample is highly correlated both when frozen within 4 h and the day after collection (r ≥ 0.98), and the estimated concentration in frozen samples was between 91 and 94% of that in fresh samples for all cell types. Using this method whole-blood samples can be frozen using a simple preparation method, and stored long-term before accurate determination of cell concentration. This allows for standardized analysis of the samples at a reference laboratory in multi-center studies. © 2016 International Clinical Cytometry Society. © 2016 International Clinical Cytometry Society.

  8. Complete blood count reference values of cord blood in Taiwan and the influence of gender and delivery route on them.

    Science.gov (United States)

    Chang, Yu-Hsun; Yang, Shang-Hsien; Wang, Tso-Fu; Lin, Teng-Yi; Yang, Kuo-Liang; Chen, Shu-Huey

    2011-06-01

    Cord blood banking has become more popular in recent years. Checking cord blood complete blood count (CBC) and white blood cell (WBC) differential counts (DCs) is essential before cryopreserving the cord blood units. Therefore, establishing the normal reference values of cord blood CBC and WBC DC is important in clinical practice and research. To obtain a large-scale population-based normal CBC and WBC DC reference values of healthy neonates' cord blood from a public cord blood bank and to investigate the influence of the gender and delivery route. From September 2001 to November 2006, the cord blood of healthy Taiwanese neonates with gestational age 36 weeks and more were collected by Tzu Chi Cord Blood Bank with written informed consents. All cord blood samples were analyzed by Sysmex XE2100 automated hematology analyzer (Sysmex Corporation, Kobe, Japan) to obtain the CBC. The WBC DC was calculated by manual method. We used Student's t test and Mann-Whitney U test for investigating the influences of gender and delivery route on the CBC and WBC DC reference values. The results were presented by mean±standard deviation or 2.5-97.5th percentiles. In the study period, totally 5602 cord blood samples were collected eligibly for analysis. The cord blood CBC and WBC DC normal reference values were calculated. The female neonates had significantly higher mean corpuscular volume, platelet count, and WBC count, but lower red blood cell (RBC) count, hemoglobin (Hb), hematocrit, and mean corpuscular Hb concentration values (pTaiwan. Gender and delivery routes were important confounding factors that influenced the cord blood CBC and WBC DC values. Copyright © 2011. Published by Elsevier B.V.

  9. Effect of exercise on erythrocyte count and blood activity concentration after technetium-99m in vivo red blood cell labeling

    International Nuclear Information System (INIS)

    Konstom, M.A.; Tu'meh, S.; Wynne, J.; Beck, J.R.; Kozlowski, J.; Holman, B.L.

    1982-01-01

    The effects of exercise on blood radiotracer concentration after technetium-99m in vivo red blood cell labeling was studied. After red blood cell labeling, 13 subjects underwent maximal supine bicycle exercise. Radioactivity, analyzed with a well counter, was measured in heparinized venous blood samples drawn at rest and during peak exercise. Changes in activity were compared with changes in erythrocyte count. Activity and erythrocyte counts increased in erythrocyte count (r=0.78), but did not correlate with either duration of exercise or maximal heart rate. Twenty minutes after termination of exercise, activity and erythrocyte count had decreased from peak exercise values but remained higher than preexercise values. In nine nonexercised control subjects, samples drawn 20 minutes apart showed no change in activity or in erythrocyte count. It was concluded that exercise increases blood activity, primarily because of an increase in erythrocyte count. During radionuclide ventriculography, blood activity must be measured before and after any intervention, particularly exercise, before a change in left ventricular activity can be attributed to a change in left ventricular volume

  10. RBC count

    Science.gov (United States)

    ... by kidney disease) RBC destruction ( hemolysis ) due to transfusion, blood vessel injury, or other cause Leukemia Malnutrition Bone ... slight risk any time the skin is broken) Alternative Names Erythrocyte count; Red blood cell count; Anemia - RBC count Images Blood test ...

  11. Establishment of reference intervals for complete blood count parameters during normal pregnancy in Beijing.

    Science.gov (United States)

    Li, Aiwei; Yang, Shuo; Zhang, Jie; Qiao, Rui

    2017-11-01

    To observe the changes of complete blood count (CBC) parameters during pregnancy and establish appropriate reference intervals for healthy pregnant women. Healthy pregnant women took the blood tests at all trimesters. All blood samples were processed on Sysmex XE-2100. The following CBC parameters were analyzed: red blood cell count (RBC), hemoglobin (Hb), hematocrit (Hct), mean corpuscular volume (MCV), mean corpuscular hemoglobin (MCH), mean corpuscular hemoglobin concentration (MCHC), red blood cell distribution width (RDW), platelet count (PLT), mean platelet volume (MPV), platelet distribution width (PDW), white blood cell count (WBC), and leukocyte differential count. Reference intervals were established using the 2.5th and 97.5th percentile of the distribution. Complete blood count parameters showed dynamic changes during trimesters. RBC, Hb, Hct declined at trimester 1, reaching their lowest point at trimester 2, and began to rise again at trimester 3. WBC, neutrophil count (Neut), monocyte count (MONO), RDW, and PDW went up from trimester 1 to trimester 3. On the contrary, MCHC, lymphocyte count (LYMPH), PLT, and MPV gradually descended during pregnancy. There were statistical significances in all CBC parameters between pregnant women and normal women, regardless of the trimesters (Ppregnancy) as follows: RBC 4.50 vs 3.94×10 12 /L, Hb 137 vs 120 g/L, WBC 5.71 vs 9.06×10 9 /L, LYMPH% 32.2 vs 18.0, Neut% 58.7 vs 75.0, and PLT 251 vs 202×10 9 /L. The changes of CBC parameters during pregnancy are described, and reference intervals for Beijing pregnant women are demonstrated in this study. © 2017 Wiley Periodicals, Inc.

  12. Polycystic ovary syndrome and the peripheral blood white cell count.

    LENUS (Irish Health Repository)

    Herlihy, A C

    2012-02-01

    This retrospective cross-sectional study examined if the white cell count (WCC) is increased in women with polycystic ovary syndrome (PCOS) and if so, is it due to PCOS or to the associated obesity? Body mass index (BMI) was calculated and body composition was measured using bioelectrical impedance analysis. Of the 113 women studied, 36 had PCOS and 77 did not. The mean WCC was higher in the PCOS group compared with the non-PCOS group (8.9 x 10(9)\\/l vs 7.4 x 10(9)\\/l p = 0.002). This increase was due to a higher neutrophil count (5.6 x 10(9)\\/l vs 4.3 x 10(9)\\/l; p = 0.003). There was a leucocytosis (WCC >11 x 10(9)\\/l) present in 19% of the PCOS group compared with 1% in the non-PCOS group (p < 0.001). The neutrophil count was abnormally high (>7.7 x 10(9)\\/l) in 14% of the PCOS group compared with 4% in the non-PCOS group (p < 0.001). On regression analysis, however, the only independent variable which explained both the increased WCC and the increased neutrophil count was PCOS. We found that PCOS is associated with an increased WCC due to increased neutrophils, which supports the evidence that PCOS is associated with low-grade inflammation. The increase appears to be due to the underlying PCOS, and not to the increased adiposity associated with PCOS.

  13. Effect of interval training program on white blood cell count in the ...

    African Journals Online (AJOL)

    Objective: Elevated white blood cell (WBC) count is considered to be prospectively and positively associated with cardiovascular diseases, particularly hypertension. Also, the positive role of exercise in the management of hypertension has been well and long established. However the relationship between WBC count and ...

  14. Association of psychological stress response of fatigue with white blood cell count in male daytime workers.

    Science.gov (United States)

    Nishitani, Naoko; Sakakibara, Hisataka

    2014-01-01

    Relationships between work-related psychological and physical stress responses and counts of white blood cells (WBCs), neutrophils, and lymphocytes were investigated in 101 daytime workers. Counts of WBCs and neutrophils were positively associated with smoking and inversely correlated with high density lipoprotein (HDL)-cholesterol levels. Additionally, general fatigue score as measured by the profile of mood state was positively correlated with WBC and neutrophil counts whereas lymphocyte counts was not significantly associated with fatigue score. Multiple regression analysis showed that WBC count was significantly related to general fatigue, age, and HDL-cholesterol levels. Neutrophil count was significantly related to HDL-cholesterol levels and fatigue score. Among various psychological stress response variables, general fatigue may be a key determinant of low-grade inflammation as represented by increases of WBC and neutrophil counts.

  15. Detection of Salmonella sp., Vibrio sp. and total plate count bacteria on blood cockle (Anadara granosa)

    Science.gov (United States)

    Ekawati, ER; Yusmiati, S. N. H.

    2018-01-01

    Blood cockle (Anadara granosa) has high level of zinc and protein, which is beneficial for therapeutic function for malnourished particularly stunting case in children. Zinc in animal foods is more absorbable than that from vegetable food. Blood cockle (Anadara granosa) is rich in nutrient and an excellent environment for the growth of microorganisms. This research aimed to identify the contamination of Salmonella sp., Vibrio sp. and total plate count bacteria on blood cockle (Anadara granosa). This was observation research with laboratory analysis. Salmonella sp. and Vibrio sp. were detected from blood cockle. Total plate count was determine of the total amount of the bacteria. Results detected from 20 samples of blood cockle showed that all samples were negative of Salmonella sp. and 1 sample positive Vibrio sp. The result of total plate count bacteria was < 5 x 105 colony/g sample.

  16. Evidence for significant influence of host immunity on changes in differential blood count during malaria.

    Science.gov (United States)

    Berens-Riha, Nicole; Kroidl, Inge; Schunk, Mirjam; Alberer, Martin; Beissner, Marcus; Pritsch, Michael; Kroidl, Arne; Fröschl, Günter; Hanus, Ingrid; Bretzel, Gisela; von Sonnenburg, Frank; Nothdurft, Hans Dieter; Löscher, Thomas; Herbinger, Karl-Heinz

    2014-04-23

    Malaria has been shown to change blood counts. Recently, a few studies have investigated the alteration of the peripheral blood monocyte-to-lymphocyte count ratio (MLCR) and the neutrophil-to-lymphocyte count ratio (NLCR) during infection with Plasmodium falciparum. Based on these findings this study investigates the predictive values of blood count alterations during malaria across different sub-populations. Cases and controls admitted to the Department of Infectious Diseases and Tropical Medicine from January 2000 through December 2010 were included in this comparative analysis. Blood count values and other variables at admission controlled for age, gender and immune status were statistically investigated. The study population comprised 210 malaria patients, infected with P. falciparum (68%), Plasmodium vivax (21%), Plasmodium ovale (7%) and Plasmodium malariae (4%), and 210 controls. A positive correlation of parasite density with NLCR and neutrophil counts, and a negative correlation of parasite density with thrombocyte, leucocyte and lymphocyte counts were found. An interaction with semi-immunity was observed; ratios were significantly different in semi-immune compared to non-immune patients (P value of the ratios was fair but limited. However, these changes were less pronounced in patients with semi-immunity. The ratios might constitute easily applicable surrogate biomarkers for immunity.

  17. Nucleated red blood cells count in pregnancies with idiopathic intra-uterine growth restriction.

    Directory of Open Access Journals (Sweden)

    Fatemeh Davari-Tanha

    2014-06-01

    Full Text Available Elevated nucleated red blood cell (NRBC count is introduced as a potential marker of intra-uterine growth restriction (IUGR. To investigate the probable association regardless of any known underlying disease, we aimed to study disturbances in NRBC count in infants experiencing idiopathic IUGR.Twenty three infants regarded IUGR without any known cause were chosen to be compared to 48 normal neonates. Blood samples were collected instantly after birth and the same measurements were done in both groups.NRBC count/100 white blood cells was significantly higher in the IUGR group (P value < 0.001. pH measurements did not reveal any significant difference.Increased NRBC count in cases of idiopathic IUGR in absence of chronic hypoxia could strengthen its predictive value suggested in previous studies. It could help early IUGR detection and beneficial intervention.

  18. Evaluation of lactate, white blood cell count, neutrophil count, procalcitonin and immature granulocyte count as biomarkers for sepsis in emergency department patients.

    Science.gov (United States)

    Karon, Brad S; Tolan, Nicole V; Wockenfus, Amy M; Block, Darci R; Baumann, Nikola A; Bryant, Sandra C; Clements, Casey M

    2017-11-01

    Lactate, white blood cell (WBC) and neutrophil count, procalcitonin and immature granulocyte (IG) count were compared for the prediction of sepsis, and severe sepsis or septic shock, in patients presenting to the emergency department (ED). We prospectively enrolled 501 ED patients with a sepsis panel ordered for suspicion of sepsis. WBC, neutrophil, and IG counts were measured on a Sysmex XT-2000i analyzer. Lactate was measured by i-STAT, and procalcitonin by Brahms Kryptor. We classified patients as having sepsis using a simplification of the 1992 consensus conference sepsis definitions. Patients with sepsis were further classified as having severe sepsis or septic shock using established criteria. Univariate receiver operating characteristic (ROC) analysis was performed to determine odds ratio (OR), area under the ROC curve (AUC), and sensitivity/specificity at optimal cut-off for prediction of sepsis (vs. no sepsis), and prediction of severe sepsis or septic shock (vs. no sepsis). There were 267 patients without sepsis; and 234 with sepsis, including 35 patients with severe sepsis or septic shock. Lactate had the highest OR (1.44, 95th% CI 1.20-1.73) for the prediction of sepsis; while WBC, neutrophil count and percent (neutrophil/WBC) had OR>1.00 (psepsis or septic shock, with an odds ratio (95th% CI) of 2.70 (2.02-3.61) and AUC 0.89 (0.82-0.96). Traditional biomarkers (lactate, WBC, neutrophil count, procalcitonin, IG) have limited utility in the prediction of sepsis. Copyright © 2017 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  19. Point-of-care blood eosinophil count in a severe asthma clinic setting.

    Science.gov (United States)

    Heffler, Enrico; Terranova, Giovanni; Chessari, Carlo; Frazzetto, Valentina; Crimi, Claudia; Fichera, Silvia; Picardi, Giuseppe; Nicolosi, Giuliana; Porto, Morena; Intravaia, Rossella; Crimi, Nunzio

    2017-07-01

    One of the main severe asthma phenotypes is severe eosinophilic or eosinophilic refractory asthma for which novel biologic agents are emerging as therapeutic options. In this context, blood eosinophil counts are one of the most reliable biomarkers. To evaluate the performance of a point-of-care peripheral blood counter in a patients with severe asthma. The blood eosinophil counts of 76 patients with severe asthma were evaluated by point-of-care and standard analyzers. A significant correlation between blood eosinophils assessed by the 2 devices was found (R 2  = 0.854, P asthma and the ELEN index, a composite score useful to predict sputum eosinophilia. The results of our study contribute to the validation of a point-of-care device to assess blood eosinophils and open the possibility of using this device for the management of severe asthma management. Copyright © 2017 American College of Allergy, Asthma & Immunology. Published by Elsevier Inc. All rights reserved.

  20. Early Colorectal Cancer Detected by Machine Learning Model Using Gender, Age, and Complete Blood Count Data.

    Science.gov (United States)

    Hornbrook, Mark C; Goshen, Ran; Choman, Eran; O'Keeffe-Rosetti, Maureen; Kinar, Yaron; Liles, Elizabeth G; Rust, Kristal C

    2017-10-01

    Machine learning tools identify patients with blood counts indicating greater likelihood of colorectal cancer and warranting colonoscopy referral. To validate a machine learning colorectal cancer detection model on a US community-based insured adult population. Eligible colorectal cancer cases (439 females, 461 males) with complete blood counts before diagnosis were identified from Kaiser Permanente Northwest Region's Tumor Registry. Control patients (n = 9108) were randomly selected from KPNW's population who had no cancers, received at ≥1 blood count, had continuous enrollment from 180 days prior to the blood count through 24 months after the count, and were aged 40-89. For each control, one blood count was randomly selected as the pseudo-colorectal cancer diagnosis date for matching to cases, and assigned a "calendar year" based on the count date. For each calendar year, 18 controls were randomly selected to match the general enrollment's 10-year age groups and lengths of continuous enrollment. Prediction performance was evaluated by area under the curve, specificity, and odds ratios. Area under the receiver operating characteristics curve for detecting colorectal cancer was 0.80 ± 0.01. At 99% specificity, the odds ratio for association of a high-risk detection score with colorectal cancer was 34.7 (95% CI 28.9-40.4). The detection model had the highest accuracy in identifying right-sided colorectal cancers. ColonFlag ® identifies individuals with tenfold higher risk of undiagnosed colorectal cancer at curable stages (0/I/II), flags colorectal tumors 180-360 days prior to usual clinical diagnosis, and is more accurate at identifying right-sided (compared to left-sided) colorectal cancers.

  1. Sample to answer visualization pipeline for low-cost point-of-care blood cell counting

    Science.gov (United States)

    Smith, Suzanne; Naidoo, Thegaran; Davies, Emlyn; Fourie, Louis; Nxumalo, Zandile; Swart, Hein; Marais, Philip; Land, Kevin; Roux, Pieter

    2015-03-01

    We present a visualization pipeline from sample to answer for point-of-care blood cell counting applications. Effective and low-cost point-of-care medical diagnostic tests provide developing countries and rural communities with accessible healthcare solutions [1], and can be particularly beneficial for blood cell count tests, which are often the starting point in the process of diagnosing a patient [2]. The initial focus of this work is on total white and red blood cell counts, using a microfluidic cartridge [3] for sample processing. Analysis of the processed samples has been implemented by means of two main optical visualization systems developed in-house: 1) a fluidic operation analysis system using high speed video data to determine volumes, mixing efficiency and flow rates, and 2) a microscopy analysis system to investigate homogeneity and concentration of blood cells. Fluidic parameters were derived from the optical flow [4] as well as color-based segmentation of the different fluids using a hue-saturation-value (HSV) color space. Cell count estimates were obtained using automated microscopy analysis and were compared to a widely accepted manual method for cell counting using a hemocytometer [5]. The results using the first iteration microfluidic device [3] showed that the most simple - and thus low-cost - approach for microfluidic component implementation was not adequate as compared to techniques based on manual cell counting principles. An improved microfluidic design has been developed to incorporate enhanced mixing and metering components, which together with this work provides the foundation on which to successfully implement automated, rapid and low-cost blood cell counting tests.

  2. Blood eosinophil count and exacerbations in severe chronic obstructive pulmonary disease after withdrawal of inhaled corticosteroids

    DEFF Research Database (Denmark)

    Watz, Henrik; Tetzlaff, Kay; Wouters, Emiel F M

    2016-01-01

    were seen with eosinophil cutoffs of 300 cells per μL and 400 cells per μL, and mutually exclusive subgroups. INTERPRETATION: Blood eosinophil counts at screening were related to the exacerbation rate after complete ICS withdrawal in patients with severe to very severe COPD and a history...... of exacerbations. Our data suggest that counts of 4% or greater or 300 cells per μL or more might identify a deleterious effect of ICS withdrawal, an effect not seen in most patients with eosinophil counts below these thresholds. FUNDING: Boehringer Ingelheim....

  3. Machine Learning Based Single-Frame Super-Resolution Processing for Lensless Blood Cell Counting

    Directory of Open Access Journals (Sweden)

    Xiwei Huang

    2016-11-01

    Full Text Available A lensless blood cell counting system integrating microfluidic channel and a complementary metal oxide semiconductor (CMOS image sensor is a promising technique to miniaturize the conventional optical lens based imaging system for point-of-care testing (POCT. However, such a system has limited resolution, making it imperative to improve resolution from the system-level using super-resolution (SR processing. Yet, how to improve resolution towards better cell detection and recognition with low cost of processing resources and without degrading system throughput is still a challenge. In this article, two machine learning based single-frame SR processing types are proposed and compared for lensless blood cell counting, namely the Extreme Learning Machine based SR (ELMSR and Convolutional Neural Network based SR (CNNSR. Moreover, lensless blood cell counting prototypes using commercial CMOS image sensors and custom designed backside-illuminated CMOS image sensors are demonstrated with ELMSR and CNNSR. When one captured low-resolution lensless cell image is input, an improved high-resolution cell image will be output. The experimental results show that the cell resolution is improved by 4×, and CNNSR has 9.5% improvement over the ELMSR on resolution enhancing performance. The cell counting results also match well with a commercial flow cytometer. Such ELMSR and CNNSR therefore have the potential for efficient resolution improvement in lensless blood cell counting systems towards POCT applications.

  4. Prevalence and clinical significance of neutropenia discovered in routine complete blood cell counts: a longitudinal study

    DEFF Research Database (Denmark)

    Andersen, Christen Bertel L; Tesfa, D.; Siersma, Volkert Dirk

    2016-01-01

    BACKGROUND: Neutropenia, defined as an absolute blood neutrophil count (ANC) neutropenia detected in a routine complete blood cell count is poorly understood. METHODS: Using a primary care resource, comprising...... more than 370 000 individuals, we assessed the association with a number of previously recognized conditions as well as all-cause mortality in the 4 years following the identification of neutropenia. By matching laboratory data with Danish nationwide health registers, risk estimates were assessed....... RESULTS: Neutropenia was observed in approximately 1% of all individuals and was associated dose dependently with viral infections, haematological malignancies (but not autoimmune disorders or solid cancers) and mortality. Neutropenia was particularly associated with HIV, acute leukaemias...

  5. Cells identification and counting in blood native state on the basis of digital microscopy.

    Directory of Open Access Journals (Sweden)

    Doubrovski V.A.

    2016-12-01

    Full Text Available The research goal is to develop an algorithm for the processing of photo images of native blood samples to determine the concentration of erythrocytes, leukocytes and platelets without individual separate preparation of cell samples. Materials and Methods. The objects of investigation were the samples of the whole donated blood, diluted 400 times by saline. Special "photo templates", the effect of "highlighting" of leukocytes, which was detect by authors, and the resolution of platelets from leukocytes by the areas of their photo images were suggested for identification of the cells. Results. 80 photo images of native blood solutions were selected for computer processing, while the total number of cells counted was: erythrocytes — 4184, platelets — 292 and leukocytes — 84, total — 4560 blood cells. Comparison of the results achieved with ones obtained by "manual" account or by the device for formed elements counting Sysmex XT-400i gives satisfactory results. Conclusion. It is shown that the accuracy of counting of the native blood cells may be comparable with the accuracy of similar studies by means of smears. At the same time the proposed analysis of native blood simplifies greatly the samples preparation in comparison to smears, permits to move from the detection of blood cells ratios to the determination of their concentrations in the sample.

  6. Signatures of reproductive events on blood counts and biomarkers of inflammation: Implications for chronic disease risk.

    Directory of Open Access Journals (Sweden)

    Daniel W Cramer

    Full Text Available Whether inflammation mediates how reproductive events affect chronic-disease risk is unclear. We studied inflammatory biomarkers in the context of reproductive events using National Health and Nutrition Examination Survey (NHANES data. From 15,986 eligible women from the 1999-2011 data cycles, we accessed information on reproductive events, blood counts, C-reactive protein (CRP, and total homocysteine (tHCY. We calculated blood-count ratios including: platelet-lymphocyte (PLR, lymphocyte-monocyte (LMR, platelet-monocyte (PMR, and neutrophil-monocyte (NMR. Using sampling weights per NHANES guidelines, means for counts, ratios, or biomarkers by reproductive events were compared using linear regression. We performed trend tests and calculated p-values with partial sum of squares F-tests. Higher PLR and lower LMR were associated with nulliparity. In postmenopausal women, lower PMR was associated with early age at first birth and higher NMR with later age at and shorter interval since last birth. Lower PNR and higher neutrophils and tHCY were associated with early natural menopause. In all women, the neutrophil count correlated positively with CRP; but, in premenopausal women, correlated inversely with tHCY. Reproductive events leave residual signatures on blood counts and inflammatory biomarkers that could underlie their links to chronic disease risk.

  7. Effect of fractionated regional external beam radiotherapy on peripheral blood cell count

    International Nuclear Information System (INIS)

    Zachariah, B.; Jacob, S.S.; Gwede, C.; Cantor, A.; Patil, J.; Casey, L.; Zachariah, A.B.

    2001-01-01

    Purpose: The purpose of this study was to assess the need for obtaining weekly complete blood count (CBC) values and to identify the pattern of changes in CBC during regional conventional fractionated radiotherapy. Methods and Materials: A retrospective analysis of CBC data on 299 adult cancer patients who received definitive conventional radiotherapy to head and neck (n=95), chest (n=96), and pelvis (n=108) was performed. Temporal patterns and magnitude of change in white blood cells, neutrophils, lymphocytes, and platelets during radiotherapy were examined. Results: There were statistically significant declines in all counts, albeit not clinically significant. Notable differences between disease sites were found. The greatest weekly interval change in counts occurred during the first week of radiotherapy for all groups of patients. The mean WBC nadir values during treatment were 5.8 for head and neck, 6.8 for chest, and 5.4 for pelvis. The nadirs for all counts occurred toward the middle-to-end of radiotherapy. Lymphocytes were found to be more sensitive to radiotherapy than other leukocyte subcomponents. Conclusion: Our study suggests that weekly CBC monitoring is not necessary for all patients undergoing standard fractionated radiotherapy. Baseline blood counts may be used to determine an optimal schedule for monitoring CBCs in patients receiving conventional radiation alone. Reduced monitoring of CBC may result in significant financial savings

  8. Lower white blood cell counts in elite athletes training for highly aerobic sports.

    Science.gov (United States)

    Horn, P L; Pyne, D B; Hopkins, W G; Barnes, C J

    2010-11-01

    White cell counts at rest might be lower in athletes participating in selected endurance-type sports. Here, we analysed blood tests of elite athletes collected over a 10-year period. Reference ranges were established for 14 female and 14 male sports involving 3,679 samples from 937 females and 4,654 samples from 1,310 males. Total white blood cell counts and counts of neutrophils, lymphocytes and monocytes were quantified. Each sport was scaled (1-5) for its perceived metabolic stress (aerobic-anaerobic) and mechanical stress (concentric-eccentric) by 13 sports physiologists. Substantially lower total white cell and neutrophil counts were observed in aerobic sports of cycling and triathlon (~16% of test results below the normal reference range) compared with team or skill-based sports such as water polo, cricket and volleyball. Mechanical stress of sports had less effect on the distribution of cell counts. The lower white cell counts in athletes in aerobic sports probably represent an adaptive response, not underlying pathology.

  9. Repair of changes in peripheral blood count of rats after chronic irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Chlebovsky, O; Praslicka, M; Chlebovska, K [Univerzita P.J. Safarika, Kosice (Czechoslovakia). Katedra Vseobecnej Biologie

    1980-01-01

    Changes are described in the peripheral blood count of rats irradiated during 120 days with doses of 95.7, 191.4, 258.4, 344.5 and 507.2 mGy/day; during 15 days with a dose of 1004.8 mGy and examined till the 180th day after termination of irradiation. The course of repair can be divided into two phases, namely: phase 1 till the 40th day after termination of irradiation when leukocyte and platelet counts reach approximately 50% of control values; this phase lasts until the 100th day after cessation of irradiation; phase 2 from the 100th till the 180th day when these peripheral blood element counts attain the level of control values. Thus in the stated conditions of irradiation, 150 to 180 days are required for radiation damage to the hemopoietic system to repair.

  10. Long-term health effects of thorium compounds on exposed workers: the complete blood count

    International Nuclear Information System (INIS)

    Conibear, S.A.

    1981-01-01

    Two hundred seventy-three men exposed to thorium and other rare earths between 1940 and 1973 at a plant which refined monazite sand were studied at Argonne National Laboratory from 1976 to 1980. In vivo measurements of body burden were made by counting gamma rays emitted by daughter products of retained thorium and by measuring exhaled thoron. Health status was ascertained through questionnaire, physical examination, and clinical laboratory tests. Measured body burden was found to be higher in those with a history of longer exposure. All parameters of the complete blood count were examined for evidence of an effect due to thorium. Comparisons of high and low body burden groups showed that only age and cigarette smoking had an effect on complete blood count parameters

  11. A rapid method for counting nucleated erythrocytes on stained blood smears by digital image analysis

    Science.gov (United States)

    Gering, E.; Atkinson, C.T.

    2004-01-01

    Measures of parasitemia by intraerythrocytic hematozoan parasites are normally expressed as the number of infected erythrocytes per n erythrocytes and are notoriously tedious and time consuming to measure. We describe a protocol for generating rapid counts of nucleated erythrocytes from digital micrographs of thin blood smears that can be used to estimate intensity of hematozoan infections in nonmammalian vertebrate hosts. This method takes advantage of the bold contrast and relatively uniform size and morphology of erythrocyte nuclei on Giemsa-stained blood smears and uses ImageJ, a java-based image analysis program developed at the U.S. National Institutes of Health and available on the internet, to recognize and count these nuclei. This technique makes feasible rapid and accurate counts of total erythrocytes in large numbers of microscope fields, which can be used in the calculation of peripheral parasitemias in low-intensity infections.

  12. Microfluidic cartridges for automated, point-of-care blood cell counting

    CSIR Research Space (South Africa)

    Smith, Suzanne

    2016-11-01

    Full Text Available Disposable, low-cost microfluidic cartridges for automated blood cell counting applications are presented in this article. The need for point-of-care medical diagnostic tools is evident, particularly in low-resource and rural settings, and a full...

  13. Establishment of new complete blood count reference values for healthy Thai adults.

    Science.gov (United States)

    Wongkrajang, P; Chinswangwatanakul, W; Mokkhamakkun, C; Chuangsuwanich, N; Wesarachkitti, B; Thaowto, B; Laiwejpithaya, S; Komkhum, O

    2018-04-28

    Laboratory reference ranges are essential for diagnostic orientation and treatment decision. As complete blood count parameters are influenced by various factors, including gender, geographic origin, and ethnic origin, it is important to establish specific hematologic reference values for specific populations. This study was conducted at the Department of Clinical Pathology, Faculty of Medicine Siriraj Hospital, Mahidol University, Bangkok, Thailand. Blood samples were taken from healthy adults aged 18-60 years that attended a health check-up program at our hospital during February 2015 to July 2015. Hematologic and routine chemistry analysis were performed. Participants were determined to be healthy based on medical history and routine medical examinations. Serum vitamin B12, folate, ferritin, and hemoglobin typing were also analyzed to exclude the possible presence of anemia. A statistically significant difference was observed between males and females for Hb level, hematocrit level, red blood cell count, mean corpuscular hemoglobin concentration, percentage neutrophils, monocytes and eosinophils, and absolute neutrophil, lymphocyte, basophil, and platelet counts. Accordingly, gender-specific reference intervals were established for all complete blood count parameters in healthy Thai adult population. The reference value ranges established in this study reflect significant differences between genders. It is possible that these reference ranges may be generalizable to adults living in Thailand. The findings of this study emphasize the importance of establishing specific hematologic reference values for specific populations. © 2018 John Wiley & Sons Ltd.

  14. White Blood Cell Count and Total and Cause-Specific Mortality in the Women's Health Initiative.

    Science.gov (United States)

    Kabat, Geoffrey C; Kim, Mimi Y; Manson, JoAnn E; Lessin, Lawrence; Lin, Juan; Wassertheil-Smoller, Sylvia; Rohan, Thomas E

    2017-07-01

    White blood cell (WBC) count appears to predict total mortality and coronary heart disease (CHD) mortality, but it is unclear to what extent the association reflects confounding by smoking, underlying illness, or comorbid conditions. We used data from the Women's Health Initiative to examine the associations of WBC count with total mortality, CHD mortality, and cancer mortality. WBC count was measured at baseline in 160,117 postmenopausal women and again in year 3 in 74,375 participants. Participants were followed for a mean of 16 years. Cox proportional hazards models were used to estimate the relative mortality hazards associated with deciles of baseline WBC count and of the mean of baseline + year 3 WBC count. High deciles of both baseline and mean WBC count were positively associated with total mortality and CHD mortality, whereas the association with cancer mortality was weaker. The association of WBC count with mortality was independent of smoking and did not appear to be influenced by previous disease history. The potential clinical utility of this common laboratory test in predicting mortality risk warrants further study. © The Author 2017. Published by Oxford University Press on behalf of the Johns Hopkins Bloomberg School of Public Health. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  15. Impact of valproates on haemostasis and blood cell count in children

    Directory of Open Access Journals (Sweden)

    Igrutinović Zoran

    2008-01-01

    Full Text Available INTRODUCTION Epilepsy is a highly prevalent disease affecting 0.5-1.5% of the world's population. One of the most frequently used antiepileptics are valproates. These medicines show a negative impact on haemostasis and peripheral blood count. OBJECTIVE The objective of the study was to examine the negative impact of valproates on haemostasis and peripheral blood count in children and to analyse whether these disturbances were dependent on the dosage of valproates and drug level in blood. METHOD A two-year research was conducted. The research included: 35 children using valproates, 12 children using the therapy of both valproates and carbamazepine and 30 healthy children. Complete peripheral blood count, screening tests of haemostasis (bleeding time, prothrombin time, prothrombin ratio, activated partial thromboplastin time, fibrinogen and capacity of thrombocyte aggregation research were done in all the children. RESULTS We found significantly more common frequency of leukopenia and neutropenia in children using valproates in comparison with the healthy children group. We also found the more common frequency of eosinophilia in comparison with healthy children. The children with the valproate therapy have lower approximate values of the number of platelets, fibrinogen and platelet aggregation in comparison with healthy children, but they have a higher approximate value of bleeding time and prothrombin time. These disturbances are in correlation with the dosage and the level of the medicine in blood. CONCLUSION Valproates have a negative effect on certain blood count parameters and haemostasis in children. Drug dosage and blood drug level are correlated with their negative impact on haemostasis parameters.

  16. Peripheral blood eosinophil counts and risk of colorectal cancer mortality in a large general population-based cohort study

    NARCIS (Netherlands)

    Taghizadeh, N.; Vonk, J.M.; Boezen, H.M.

    2011-01-01

    1583 Background: Few epidemiological studies have investigated the association between blood eosinophil counts and colorectal cancer incidence. The current prospective cohort study aims to investigate the association between peripheral blood eosinophils and colorectal cancer mortality risk. METHODS:

  17. Blood eosinophil counts for the prediction of the severity of exercise-induced bronchospasm in asthma.

    Science.gov (United States)

    Koh, Y I; Choi, S

    2002-02-01

    It has been suggested that airway eosinophilic inflammation is associated with the severity of exercise-induced bronchospasm (EIB). Blood eosinophils are known to be an indirect marker of airway inflammation in asthma. The aim of this study is to investigate that a simple and easy blood test for blood eosinphil counts may predict the severity of EIB in asthma. Seventy-seven men with perennial asthma (age range 18-23 years) were included. Lung function test, skin prick test, and blood tests for eosinophils counts and total IgE levels were performed. Methacholine bronchial provocation test and, 24 h later, free running test were carried out. EIB was defined as a 15% reduction or more in post-exercise FEV1 compared with pre-exercise FEV1 value. Atopy score was defined as a sum of mean wheal diameters to allergens. EIB was observed in 60 (78%) of 77 subjects. Asthmatics with EIB showed significantly increased percentages of eosinophils (P 700 microl(-1) (36.9 +/- 12.7%) had significantly greater maximal % fall in FEV1 after exercise than asthmatics with eosinophils of 350 microl(-1) yielded the specificity of 88% and positive predictive value of 93% for the presence of EIB. When a multiple regression analysis of maximal % fall in FEV1 according to log eosinophil counts, log PC20, log IgE and atopy score was performed, only blood eosinophil counts were significant factor contributing to the maximal % fall in FEV1 after exercise. These findings not only suggest that a simple blood test for eosinophils may be useful in the prediction of the severity of EIB, but also reinforce the view that airway eosinophilic inflammation may play a major role in EIB in asthma.

  18. Effect of scaling and root planing on blood counts in patients with chronic generalized periodontitis

    Directory of Open Access Journals (Sweden)

    Devinder Singh Kalsi

    2017-01-01

    Full Text Available Background: Many systemic diseases have been implicated as risk factors in periodontal disease. Studies suggest that periodontal infection can adversely affect systemic health; by inference periodontal disease will also have an effect on blood values, but the data available is not conclusive. Aim: This clinical study was designed to evaluate the effect of treatment of plaque induced periodontitis on commonly assessed blood parameters. Materials and Method: 37 males and 31 females aged between 20 and 50 years in good general health but suffering from plaque induced chronic periodontitis were selected for the study. The selected patients were assessed for ESR, TLC, PMN count, lymphocyte count from DLC, HB, BT and their periodontal condition before the start of the study. SCRP was carried out and patients were reassessed for the same clinical and hematological parameters 21 days after the periodontal therapy (SCRP. Results: A highly significant reduction in the counts of PMNs and the values of ESI was seen after SCRP. Furthermore a significant reduction in TLC, lymphocytes count, and BT and a non significant decrease in Hb were also observed. Conclusion: SCRP done in patients of chronic periodontitis has a considerable affect on the assessed blood parameters.

  19. CORD BLOOD NUCLEATED RED BLOOD CELL COUNT: A SIMPLE BEDSIDE TEST OF PERINATAL ASPHYXIA AND ITS CORRELATION WITH IMMEDIATE OUTCOME

    Directory of Open Access Journals (Sweden)

    Ramesh Chand

    2016-07-01

    Full Text Available BACKGROUND Asphyxia is a leading cause of foetal neonatal mortality and morbidity. Nucleated red blood cell count (NRBC produced as compensatory response to asphyxia in foetus and NRBC level can be correlated to asphyxia. Because the present indices are unhelpful in the diagnosis and prediction of the severity of asphyxia, we wished to investigate the relationship between the nucleated RBC count and the severity & immediate outcome of perinatal asphyxia. METHOD This prospective comparative study was conducted in maternity ward of Obstetrics & Gynaecology Department and Paediatric Department of GSVM Medical College, Kanpur (Central UP, from January 2014 to September 2014. Newborns of term gestation were selected after satisfying inclusion criteria and were divided in 2 groups. The control group consisted 60 normal newborns and case group had 60 asphyxiated newborns. The cord blood was collected soon after birth, investigated for pH and making smears that were stained with Leishman’s stain. NRBCs were counted against 100 WBCs. The statistical analysis was done using IMSTAT. RESULTS The mean NRBC count in the study group was 22.63±6.95 as compared to 4.75±2.04 in the control group (p=<0.0001. The NRBC count was significantly higher in low pH, neonates with low Apgar scores of < 3 at 1 minutes, newborns with HIE stage III & in neonates who were neurological abnormal at discharge (P=0.0001. CONCLUSIONS A simple, easy to do, cost effective bedside test, such as NRBC count at time of delivery is a good marker of perinatal asphyxia & its forthcoming immediate neurological outcome.

  20. Establishment of reference values for complete blood count and blood gases in cynomolgus monkeys (Macaca fascicularis)

    Science.gov (United States)

    NAKAYAMA, Shunya; KOIE, Hiroshi; KANAYAMA, Kiichi; KATAKAI, Yuko; ITO-FUJISHIRO, Yasuyo; SANKAI, Tadashi; YASUTOMI, Yasuhiro; AGEYAMA, Naohide

    2017-01-01

    Cynomolgus monkeys are closely related to humans phylogenetically, and this has resulted in their widespread use as a preclinical model. Hematological data with regard to these monkeys are thus important. Although reference values for blood components and sex hormones have been established for cynomolgus monkeys, those for arterial blood gases have not. The arterial blood gases quickly reflect respiratory and circulatory dynamics, and are thus useful for animal management and safe general anesthesia and surgical operations. Furthermore, since O2 is transported by RBC, CBC and blood gases are closely related. The present study aimed to establish reference values for arterial blood gases and CBC in cynomolgus monkeys over a wide age range. Blood gases and CBC of arterial blood, collected from 41 female and 21 male anesthetized monkeys, were measured. Age correlated with RBC, HGB and HCT in the CBC. Values differed significantly between males and females in pCO2, CO2 concentration, MCV and MCH. The pH of blood was equivalent to that of humans and pCO2 was more stable, whereas MCV and MCH were lower than those in humans. Erythrocytes were smaller and less pigmented than in other Macaca species. Several relationships between gender and age, and blood gases and CBC were identified in cynomolgus monkeys. In conclusion, these reference values will be useful as markers for veterinary applications and in the care and maintenance of these animals. PMID:28381665

  1. The effect of blood cell count on coronary flow in patients with coronary slow flow phenomenon.

    Science.gov (United States)

    Soylu, Korhan; Gulel, Okan; Yucel, Huriye; Yuksel, Serkan; Aksan, Gokhan; Soylu, Ayşegül İdil; Demircan, Sabri; Yılmaz, Ozcan; Sahin, Mahmut

    2014-09-01

    The coronary slow flow phenomenon (CSFP) is a coronary artery disease with a benign course, but its pathological mechanisms are not yet fully understood.The purpose of this controlled study was to investigate the cellular content of blood in patients diagnosed with CSFP and the relationship of this with coronary flow rates. Selective coronary angiographies of 3368 patients were analyzed to assess Thrombolysis in Myocardial Infarction (TIMI) frame count (TFC) values. Seventy eight of them had CSFP, and their demographic and laboratory findings were compared with 61 patients with normal coronary flow. Patients' demographic characteristics were similar in both groups. Mean corrected TFC (cTFC) values were significantly elevated in CSFP patients (p<0.001). Furthermore, hematocrit and hemoglobin values, and eosinophil and basophil counts of the CSFP patients were significantly elevated compared to the values obtained in the control group (p=0.005, p=0.047, p=0.001 and p=0.002, respectively). The increase observed in hematocrit and eosinophil levels showed significant correlations with increased TFC values (r=0.288 and r=0.217, respectively). Significant changes have been observed in the cellular composition of blood in patients diagnosed with CSFP as compared to the patients with normal coronary blood flow. The increases in hematocrit levels and in the eosinophil and basophil counts may have direct or indirect effects on the rate of coronary blood flow.

  2. Fetal blood vessel count increases in compensation of hypoxia in premature placentas

    Directory of Open Access Journals (Sweden)

    K. Kartini

    2015-04-01

    Full Text Available Background Prematurity refers to live births before 37 weeks of gestation, wherein the baby is born before the body and its organ systems achieve perfect maturity, and this disorder is still a global problem. The high incidence of prematurity is a problem in developing and also in developed countries. Certain conditions accompanying pregnancies like preeclampsia, infection, and placental insufficiency, may trigger uterine hypoxia, causing premature birth. The placental condition is related to the intra-uterine fetal condition. In prolonged placental hypoxia, there occurs a compensatory mechanism, i.e. an increase in placental angiogenesis. This study aimed to evaluate the effect of hypoxia on fetal blood vessel count as compensatory mechanism for tissue hypoxia. Methods An observational-analytical cross-sectional design using paraffin blocks of conserved premature placentas, comprising 31 samples of hypoxic premature placentas and 28 samples of non-hypoxic premature placentas, selected using non-random consecutive sampling. The samples were made into slides and stained with hematoxylin-eosin for assessment of histological structure, including fetal blood vessel count and integrity, villus conditions, syncytiotrophoblastic nuclear changes, and syncytiotrophoblastic nuclear aggregation. Mann-Whitney test was used to compare the difference of blood vessel count between groups. Results Assessment of histological structure showed a significant increase in fetal blood vessel count in the hypoxic group [8.00 (5-15] as compared with the non-hypoxic group [7.50 (3-15]. Conclusion The hypoxia in premature placentas caused an increase in the number of fetal blood vessels as a form of compensation for disturbed oxygen homeostasis.

  3. Fetal blood vessel count increases in compensation of hypoxia in premature placentas

    Directory of Open Access Journals (Sweden)

    K Kartini

    2016-02-01

    Full Text Available BACKGROUND Prematurity refers to live births before 37 weeks of gestation, wherein the baby is born before the body and its organ systems achieve perfect maturity, and this disorder is still a global problem. The high incidence of prematurity is a problem in developing and also in developed countries. Certain conditions accompanying pregnancies like preeclampsia, infection, and placental insufficiency, may trigger uterine hypoxia, causing premature birth. The placental condition is related to the intra-uterine fetal condition. In prolonged placental hypoxia, there occurs a compensatory mechanism, i.e. an increase in placental angiogenesis. This study aimed to evaluate the effect of hypoxia on fetal blood vessel count as compensatory mechanism for tissue hypoxia. METHODS An observational-analytical cross-sectional design using paraffin blocks of conserved premature placentas, comprising 31 samples of hypoxic premature placentas and 28 samples of non-hypoxic premature placentas, selected using non-random consecutive sampling. The samples were made into slides and stained with hematoxylin-eosin for assessment of histological structure, including fetal blood vessel count and integrity, villus conditions, syncytiotrophoblastic nuclear changes, and syncytiotrophoblastic nuclear aggregation. Mann-Whitney test was used to compare the difference of blood vessel count between groups. RESULTS Assessment of histological structure showed a significant increase in fetal blood vessel count in the hypoxic group [8.00 (5-15] as compared with the non-hypoxic group [7.50 (3-15]. CONCLUSION The hypoxia in premature placentas caused an increase in the number of fetal blood vessels as a form of compensation for disturbed oxygen homeostasis.

  4. Blood neutrophil counts in HIV-infected patients with pulmonary tuberculosis: association with sputum mycobacterial load.

    Directory of Open Access Journals (Sweden)

    Andrew D Kerkhoff

    Full Text Available Increasing evidence suggests that neutrophils play a role in the host response to Mycobacterium tuberculosis. We determined whether neutrophil counts in peripheral blood are associated with tuberculosis (TB and with mycobacterial load in sputum in HIV-infected patients.Adults enrolling in an antiretroviral treatment (ART clinic in a Cape Town township were screened for TB regardless of symptoms. Paired sputum samples were examined using liquid culture, fluorescence microscopy, and the Xpert MTB/RIF assay. Absolute neutrophil counts (ANC were measured in blood samples. Of 602 HIV-infected patients screened, 523 produced one or more sputum samples and had complete results available for analysis. Among these 523 patients, the median CD4 count was 169×10(9/L (IQR, 96-232 and median ANC was 2.6×10(9/L (IQR, 1.9-3.6. Culture-positive pulmonary tuberculosis was diagnosed in 89 patients. Patients with TB had a median ANC of 3.4×10(9/L (IQR, 2.4-5.1 compared to 2.5×10(9/L (IQR, 1.8-3.4 among those who were culture negative (p7.5×10(9/L; p = 0.0005. Patients were then classified into four mutually exclusive groups with increasing sputum mycobacterial load as defined by the results of culture, Xpert MTB/RIF and sputum smear microscopy. Multivariable analyses demonstrated that increasing sputum mycobacterial load was positively associated with blood ANC ≥2.6×10(9/L and with neutrophilia.Increased blood neutrophil counts were independently associated with pulmonary TB and sputum mycobacterial burden in this HIV-infected patient group. This observation supports the growing body of literature regarding the potential role for neutrophils in the host response to TB.

  5. Adaptive and automatic red blood cell counting method based on microscopic hyperspectral imaging technology

    Science.gov (United States)

    Liu, Xi; Zhou, Mei; Qiu, Song; Sun, Li; Liu, Hongying; Li, Qingli; Wang, Yiting

    2017-12-01

    Red blood cell counting, as a routine examination, plays an important role in medical diagnoses. Although automated hematology analyzers are widely used, manual microscopic examination by a hematologist or pathologist is still unavoidable, which is time-consuming and error-prone. This paper proposes a full-automatic red blood cell counting method which is based on microscopic hyperspectral imaging of blood smears and combines spatial and spectral information to achieve high precision. The acquired hyperspectral image data of the blood smear in the visible and near-infrared spectral range are firstly preprocessed, and then a quadratic blind linear unmixing algorithm is used to get endmember abundance images. Based on mathematical morphological operation and an adaptive Otsu’s method, a binaryzation process is performed on the abundance images. Finally, the connected component labeling algorithm with magnification-based parameter setting is applied to automatically select the binary images of red blood cell cytoplasm. Experimental results show that the proposed method can perform well and has potential for clinical applications.

  6. Neutropenia Prediction Based on First-Cycle Blood Counts Using a FOS-3NN Classifier

    Directory of Open Access Journals (Sweden)

    Elize A. Shirdel

    2011-01-01

    Full Text Available Background. Delivery of full doses of adjuvant chemotherapy on schedule is key to optimal breast cancer outcomes. Neutropenia is a serious complication of chemotherapy and a common barrier to this goal, leading to dose reductions or delays in treatment. While past research has observed correlations between complete blood count data and neutropenic events, a reliable method of classifying breast cancer patients into low- and high-risk groups remains elusive. Patients and Methods. Thirty-five patients receiving adjuvant chemotherapy for early-stage breast cancer under the care of a single oncologist are examined in this study. FOS-3NN stratifies patient risk based on complete blood count data after the first cycle of treatment. All classifications are independent of breast cancer subtype and clinical markers, with risk level determined by the kinetics of patient blood count response to the first cycle of treatment. Results. In an independent test set of patients unseen by FOS-3NN, 19 out of 21 patients were correctly classified (Fisher’s exact test probability P<0.00023 [2 tailed], Matthews’ correlation coefficient +0.83. Conclusions. We have developed a model that accurately predicts neutropenic events in a population treated with adjuvant chemotherapy in the first cycle of a 6-cycle treatment.

  7. Application of blood cell count and retrospective biodosimetry for health protection in industrial radiographers

    Energy Technology Data Exchange (ETDEWEB)

    Jang, Seong Jae; Kim, Seung Hyun; Yang, Soo San; Cho, Min Su; Lee, Jin Kyung; Jin, Young Woo [Korea Institute of Radiological and Medical Sciences, Seoul (Korea, Republic of)

    2017-04-15

    Industrial radiography is known to be one of the most vulnerable lines of work among the range of different radiation work. According to the relevant law in Korea, every worker registered in this work should check their blood cell counts every year in addition to their thermoluminescent dosimeter (TLD) doses. Cytogenetic dosimetry has been employed for several decades as a method for estimating the dose of ionizing radiation (IR) received by an individual. In cases of recent acute exposure, the most reliable method is to score dicentric chromosomes in solid-stained metaphase cells. Dicentric aberrations are unstable because their frequency decrease with time after IR exposure. The purpose of the present study was to review the effectiveness of the current regulation that requires all registered radiation workers to check their blood counts every year in order to screen for exposed workers. In addition, the clinical usefulness of cytogenetic dosimetry as a retrospective tool for dose estimation has been evaluated. From this study, we hope to make practical recommendations for improving the current radiation protection regulation. We ascertain that reviewing consecutive results of blood cell counts and retrospective biodosimetry are useful complementary tools to TLD doses for health protection regulation. Several confounding factors including work duration and previous medical history need to be considered for the interpretation of cytogenetic dosimetry results.

  8. Peripheral blood leukocyte count as an index of defense status in the leukopenic host

    International Nuclear Information System (INIS)

    Cawley, S.; Findon, G.; Miller, T.E.

    1988-01-01

    These experimental studies have investigated the reliability of the peripheral blood leukocyte count to predict whether the leukopenic host can contain or eliminate infection. Additionally, we have investigated the possibility that determination of leukocyte recruitment, supplementary to peripheral blood leukocyte counts, might allow individuals with neutropenia at risk from serious infection to be distinguished with greater certainty. Varying doses of radiation, cyclophosphamide, and methylprednisolone were used to induce distinct levels of leukopenia in rats. Leukocyte recruitment was measured by quantifying the response of neutropenic animals to evocative, subcutaneous stimuli, and the results of this assay were then compared with circulating leukocyte counts in the same individuals. Six models of experimentally induced infection were used to compare circulating and recruitable leukocytes as indicators of the susceptibility of the leukopenic host to infection. Response curves relating leukocyte numbers to host resistance were similar when circulating or recruitable leukocytes were used as an index of defense capability. These findings support the use of peripheral blood leukocyte numbers as an index of resistance to infection in individuals with leukopenia and suggest that functional analyses such as leukocyte recruitment are unlikely to provide additional information

  9. Association between red blood cell indices and CD4 count in HIV-positive reproductive women

    Science.gov (United States)

    Lumbanraja, S. N.; Siregar, D. I. S.

    2018-03-01

    Red blood cell indices, hemoglobin, and hematocrit reflect rapidity of HIV disease progression. This study aims to determine red blood cell indices and CD4 count in HIV-positive reproductive women. This study was a cross sectional study conducted at AIDS outpatient clinic at Haji Adam Malik General Hospital, Medan Indonesia. All seropositive reproductive women within antiretroviral therapy consented for blood count and CD4 examination. Data were collected and analyzed with SPSS 19. In subjects with CD4≤350 mm3, mean hemoglobin was 10.95 ± 2.01, hematocrit was 31.83 ± 5.04%, MCV was 84.17 ± 11.41, MCH was 25.98 ± 2.65, and MCHC was 32.18 ± 2.17. Mean hemoglobin, hematocrit, and MCH value was significantly lower in subjects with CD4 ≤350 mm3 (p=0.014; p=0.001; p=0.01; respectively). Lower Hb, Ht, and MCH associated with thelower CD4 count.

  10. Application of blood cell count and retrospective biodosimetry for health protection in industrial radiographers

    International Nuclear Information System (INIS)

    Jang, Seong Jae; Kim, Seung Hyun; Yang, Soo San; Cho, Min Su; Lee, Jin Kyung; Jin, Young Woo

    2017-01-01

    Industrial radiography is known to be one of the most vulnerable lines of work among the range of different radiation work. According to the relevant law in Korea, every worker registered in this work should check their blood cell counts every year in addition to their thermoluminescent dosimeter (TLD) doses. Cytogenetic dosimetry has been employed for several decades as a method for estimating the dose of ionizing radiation (IR) received by an individual. In cases of recent acute exposure, the most reliable method is to score dicentric chromosomes in solid-stained metaphase cells. Dicentric aberrations are unstable because their frequency decrease with time after IR exposure. The purpose of the present study was to review the effectiveness of the current regulation that requires all registered radiation workers to check their blood counts every year in order to screen for exposed workers. In addition, the clinical usefulness of cytogenetic dosimetry as a retrospective tool for dose estimation has been evaluated. From this study, we hope to make practical recommendations for improving the current radiation protection regulation. We ascertain that reviewing consecutive results of blood cell counts and retrospective biodosimetry are useful complementary tools to TLD doses for health protection regulation. Several confounding factors including work duration and previous medical history need to be considered for the interpretation of cytogenetic dosimetry results.

  11. The investigation of complete blood counting parameters in deep venous thrombosis

    Directory of Open Access Journals (Sweden)

    Ahmet Çalışkan

    2014-03-01

    Full Text Available Objective: The role of inflammation in the deep venous thrombosis (DVT process has been explained in various studies. Hence, the role of inflammatory markers in this illness has been researched previouslyin the literature. Recent years, such as parameters, neutrophil lymphocyte ratio (NLR and platelet lymphocyte ratio (PLR, among complete blood count have been frequently started to use as an expression of inflammatory marker. In the current study, the relation between complete blood count parameters and DVT was investigated. Methods: 50 patients admitted to our clinic with the diagnosis of acute DVT (28 female, 22 male were included in the study. The patients were diagnosed by clinical symptoms and Doppler USG. Patients with additional illness that can form an inflammatory response were excluded. 30 healthy volunteers were included as a control group. Routine complete blood counts of these patients were examined retrospectively. Routine complete blood counts and nonselective inflammatory markers, red cell distribution width (RDW, white cells (WBC, NLR, and PLR measurements were examined statistically. Results: The mean age of patients included in study was 46.2±14.2 and 53% of them were female. When the groups were examined in terms of hematological parameters, lymphocyte (2.6±0.8 and 2.1±0.7, p=0.003 and platelet (322±144 and 264±66, p=0.042 values were detected to be higher. Hemoglobin (13.2±2.0 and 14.6±1.5, p=0.002 and hematocrit (38.7±5.1 and 42.8±6.9, p<0.001 values were detected to be less while the WBC, neutrophil, NLR, RDW and PLR were similar. Regarding the two groups with and without anticoagulant therapy, in the DVT group, there were no significant differences detected in terms of age, gender, and hematological parameters. Conclusion: In this study, there were no significant differences between healthy volunteers blood count parameters of patients taken into consideration with pure DVT. There is no significant change shown.

  12. On-chip sample preparation for complete blood count from raw blood.

    Science.gov (United States)

    Nguyen, John; Wei, Yuan; Zheng, Yi; Wang, Chen; Sun, Yu

    2015-03-21

    This paper describes a monolithic microfluidic device capable of on-chip sample preparation for both RBC and WBC measurements from whole blood. For the first time, on-chip sample processing (e.g. dilution, lysis, and filtration) and downstream single cell measurement were fully integrated to enable sample preparation and single cell analysis from whole blood on a single device. The device consists of two parallel sub-systems that perform sample processing and electrical measurements for measuring RBC and WBC parameters. The system provides a modular environment capable of handling solutions of various viscosities by adjusting the length of channels and precisely controlling mixing ratios, and features a new 'offset' filter configuration for increased duration of device operation. RBC concentration, mean corpuscular volume (MCV), cell distribution width, WBC concentration and differential are determined by electrical impedance measurement. Experimental characterization of over 100,000 cells from 10 patient blood samples validated the system's capability for performing on-chip raw blood processing and measurement.

  13. The hematology of captive Bobtail lizards (Tiliqua rugosa): blood counts, light microscopy, cytochemistry, and ultrastructure.

    Science.gov (United States)

    Moller, Cheryl A; Gaál, Tibor; Mills, Jennifer N

    2016-12-01

    Bobtail lizards (Tiliqua rugosa) are native to Australia. The only previous study on the hematology of this species documented just 6 animals. The aims of this study were to characterize the light microscopy, ultrastructure and cytochemistry of blood cells, and evaluate CBCs of captive Bobtail lizards. Over 2 consecutive summers, heparinized venous blood was collected from the ventral coccygeal vein of 46 clinically healthy, captive indoor- or outdoor-housed adult Bobtails. Complete blood cell counts and smear evaluations were performed, and cytochemical stains and transmission electron microscopy were used to further characterize blood cells. The eosinophils of this species were uniformly vacuolated: a unique feature not previously reported in reptiles. Heterophils were the predominant leukocyte, with fewer lymphocytes, azurophilic and nonazurophilic monocytes, occasional eosinophils, and basophils. Thrombocytes were frequently clumped. Slight polychromasia (0-15% of erythrocytes) was typically present. Hemogregarine parasites were seen on some smears. The range of CBC results was often wide. The PCV ranged from 11% to 38%. Total plasma proteins by refractometry were between 3.5 and 7.8 g/dL. Hemoglobin ranged between 2.6 and 12.6 g/dL by the modified hemoglobin-hydroxylamine method. Manual RBC count was 0.35-1.27 × 10 6 /μL, and WBC count was 2.86-22.66 × 10 3 /μL. Bobtail lizards housed outdoors had lower PCVs than indoor-housed animals. Bobtails with hemogregarine infections had lower PCVs than noninfected lizards. Ranges for CBC data were often very wide, influenced by preanalytic and analytic factors. Hemogregarine infection is associated with a decreased PCV, suggesting that some hemogregarine species are pathogenic in this population. © 2016 American Society for Veterinary Clinical Pathology.

  14. Sex differences in step count-blood pressure association: a preliminary study in type 2 diabetes.

    Directory of Open Access Journals (Sweden)

    Priya Manjoo

    Full Text Available BACKGROUND: Walking and cardiovascular mortality are inversely associated in type 2 diabetes, but few studies have objectively measured associations of walking with individual cardiovascular risk factors. Such information would be useful for "dosing" daily steps in clinical practice. This study aimed to quantify decrements in blood pressure and glycated hemoglobin (A1C per 1,000 daily step increments. METHODOLOGY/PRINCIPAL FINDINGS: Two hundred and one subjects with type 2 diabetes underwent assessments of step counts (pedometer-measured, blood pressure, A1C and anthropometric parameters. Due to missing data, the final analysis was conducted on 83 women and 102 men, with a mean age of 60 years. Associations of daily steps with blood pressure and A1C were evaluated using sex-specific multivariate linear regression models (adjusted for age, ethnicity, and BMI. Potential sex differences were confirmed in a combined model (women and men with interaction terms. Mean values for daily steps, blood pressure, A1C and BMI were 5,357 steps/day; 137/80 mm Hg; 7.7% and 30.4 kg/m(2 respectively. A 1,000 daily step increment among women was associated with a -2.6 (95% CI: -4.1 to -1.1 mm Hg change in systolic and a -1.4 (95% CI: -2.2 to -0.6 mm Hg change in diastolic blood pressure. Among men, corresponding changes were -0.7 (95% CI: -2.1 to 0.7 and -0.6 (95% CI: -1.4 to 0.3 mm Hg, respectively. Sex differences were confirmed in combined models. Step counts and A1C did not demonstrate clinically important associations. CONCLUSIONS/SIGNIFICANCE: A 1,000 steps/day increment is associated with important blood pressure decrements among women with type 2 diabetes but the data were inconclusive among men. Targeted "dose increments" of 1,000 steps/day in women may lead to measurable blood pressure reductions. This information may be of potential use in the titration or "dosing" of daily steps. No associations were found between step count increments and A1C.

  15. Children's white blood cell counts in relation to developmental exposures to methylmercury and persistent organic pollutants

    DEFF Research Database (Denmark)

    Oulhote, Youssef; Shamim, Z; Kielsen, Katrine

    2017-01-01

    ), and total mercury (Hg) were measured in maternal (n = 56) and children's blood at 18 months (n = 42) and 5 years (n = 54). We constructed latent functions for exposures at three different ages using factor analyses and applied structural equation models adjusted for covariates. Results Prenatal mercury....... In contrast, the 5-year PFASs concentrations were associated with higher basophil counts (B = 46% SD, 95% CI: 13, 79). Significantly reduced subpopulations of lymphocytes such as B cells, CD4-positive T helper cells and CD4 positive recent thymic emigrants may suggest cellular immunity effects...... and dysregulation of T-cell mediated immunity. Conclusion Developmental exposure to environmental immunotoxicants appears to have different impacts on WBC counts in childhood....

  16. THE EFFECT OF BLOOD AND MILK SERUM ZINC CONCENTRATION ON MILK SOMATIC CELL COUNT IN DAIRY COWS

    Directory of Open Access Journals (Sweden)

    Ivana Davidov

    2016-11-01

    Full Text Available The objective of this study was to evaluate the effect of blood and milk zinc concentration on somatic cell count and occurrence of subclinical mastitis cases. The study was performed on thirty Holstein cows approximate same body weight, ages 3 to 5 years, with equally milk production. Blood samples were taken after the morning milking from the caudal vein and milk from all four quarters was taken before morning milking. All samples of blood and milk were taken to determined zinc, using inductively coupled plasma mass spectrometry. 37.67% (11/30 cows have blood serum zinc concentration below 7µmol/l, and 63.33% or 19/30 cows have blood serum zinc concentration higher then 13µmol/l. Also 30% (9/30 cows have somatic cell count lower then 400.000/ml which indicate absence of subclinical mastitis, but 70% (21/30 cows have somatic cell count higher then 400.000/ml which indicate subclinical mastitis. Results indicate that cows with level of zinc in blood serum higher then 13 µmol/l have lower somatic cell count. Cows with lower zinc blood serum concentration then 7 µmol/l have high somatic cell count and high incidence of subclinical mastitis. According to results in this research there is no significant effect of milk serum zinc concentration on somatic cell count in dairy cows.

  17. Toward unstained cytology and complete blood counts at the point of care (Conference Presentation)

    Science.gov (United States)

    Zuluaga, Andres F.; Pierce, Mark C.; MacAulay, Calum E.

    2017-02-01

    Cytology tests, whether performed on body fluids, aspirates, or scrapings are commonly used to detect, diagnose, and monitor a wide variety of health conditions. Complete blood counts (CBCs) quantify the number of red and white blood cells in a blood volume, as well as the different types of white blood cells. There is a critical unmet need for an instrument that can perform CBCs at the point of care (POC), and there is currently no product in the US that can perform this test at the bedside. We have developed a system that is capable of tomographic images with sub-cellular resolution with consumer-grade broadband (LED) sources and CMOS detectors suitable for POC implementation of CBC tests. The systems consists of cascaded static Michelson and Sagnac interferometers that map phase (encoding depth) and a transverse spatial dimension onto a two-dimensional output plane. Our approach requires a 5 microliter sample, can be performed in 5 minutes or less, and does not require staining or other processing as it relies on intrinsic contrast. We will show results directly imaging and differentiating unstained blood cells using supercontinuum fiber lasers and LEDs as sources and CMOS cameras as sensors. We will also lay out the follow up steps needed, including image segmentation, analysis and classification, to verify performance and advance toward CBCs that can be performed bedside and do not require CLIA-certified laboratories.

  18. White blood cell counts, insulin resistance, vitamin D levels and sarcopenia in Korean elderly men.

    Science.gov (United States)

    Kim, Sang-Hwan; Kwon, Hyun Seok; Hwang, Hee-Jin

    2017-05-01

    Sarcopenia is a major determinant of frailty, disability and mortality in the elderly. Whether low-grade inflammation, insulin resistance and vitamin D are independently associated with sarcopenia remains unclear. In our study, sarcopenia was defined as an appendicular skeletal muscle mass divided by height squared (ASM/Ht 2 ) that was sarcopenia in Korean elderly men aged more than 65 years was 11.2%. ASM/Ht 2 were positively associated with vitamin D levels, but negatively associated with white blood cell counts and HOMA-IR by multiple regression analysis. After adjustment for covariables, sarcopenia was associated with the highest quartile of WBC counts (OR = 2.93, 95% CI = 1.21-7.14) and the highest quartile of serum vitamin D levels (OR = 0.38, 95% CI = 0.15-0.95). In conclusion, the study findings suggest that higher WBC counts and lower vitamin D levels are independently associated with the presence of sarcopenia in community-dwelling elderly men. They also provide a basis for further studies of the complex immune-endocrine network in sarcopenia.

  19. Relationship of white blood cell counts, haemoglobin and ESR with IHD

    International Nuclear Information System (INIS)

    Shahzad, F.; Shahzad Tawwab, S.; Abbas, A.

    2009-01-01

    To find any association of white blood cells, haemoglobin and ESR with ischemic heart disease in high risk native population. Methodology: The study included 93 male patients with Ischemic heart disease, between 40 and 60 years of age; 96 age and gender matched subjects. All study participants were non-diabetics. Complete blood cells count, haemoglobin and ESR levels were compared between the patient and control groups. Results: Total leukocyte counts along with neutrophils were significantly higher in the test group compared to the control population (p<0.001) and lymphocytes were significantly lower (p<0.001) in the patient group as compared to the control group. Haemoglobin levels were significantly lower (p<0.001) and ESR was higher (p=0.030) in the patient group as compared to the control group. Conclusion: Although, our findings of the study variables extend previous reports, the prevalence and prognostic importance of theses variables in IHD should be assessed in future experimental studies. These parameters could be important in public health because they are routinely measured by clinicians and may be helpful to predict the risk of future and secondary ischemic events in a high risk population. (author)

  20. Acute effects of electronic and tobacco cigarette smoking on complete blood count.

    Science.gov (United States)

    Flouris, Andreas D; Poulianiti, Konstantina P; Chorti, Maria S; Jamurtas, Athanasios Z; Kouretas, Dimitrios; Owolabi, Emmanuel O; Tzatzarakis, Manolis N; Tsatsakis, Aristidis M; Koutedakis, Yiannis

    2012-10-01

    The World Health Organisation called for research assessing the safety of electronic cigarette (e-cigarette). We evaluated the acute effect of active and passive e-cigarette and tobacco cigarette smoking on complete blood count (CBC) markers in 15 smokers and 15 never-smokers, respectively. Smokers underwent a control session, an active tobacco cigarette smoking session, and an active e-cigarette smoking session. Never-smokers underwent a control session, a passive tobacco cigarette smoking session, and a passive e-cigarette smoking session. The results demonstrated that CBC indices remained unchanged during the control session and the active and passive e-cigarette smoking sessions (P>0.05). Active and passive tobacco cigarette smoking increased white blood cell, lymphocyte, and granulocyte counts for at least one hour in smokers and never smokers (Pissues and other areas of consumer product safety of e-cigarettes, because the nicotine content in the liquids used may vary considerably. Copyright © 2012 Elsevier Ltd. All rights reserved.

  1. White blood cell counts mediate the effects of physical activity on prostate-specific antigen levels.

    Science.gov (United States)

    Loprinzi, Paul D; Richart, Sarah M

    2014-09-01

    The purpose of this study was to examine whether white blood cell (WBC) level mediated the relationship between physical activity and prostate-specific antigen (PSA) levels. Data from the 2003-2006 National Health and Nutrition Examination Survey were used; 1,726 U.S. adult men (aged 40 years or older) provided complete data on the study variables. Participants wore an ActiGraph 7164 accelerometer for a 7-day period to measure their physical activity behavior, and PSA and WBC levels were obtained from a blood sample. After adjustments, results showed that moderate-to-vigorous physical activity (MVPA) was inversely associated with WBC count (b = - .03; 95% CI [ - 0.04, - 0.006; p = .01), and WBC count (b = .10; 95% CI [0.009, 0.18; p = .04) was positively associated with PSA. Both the Sobel (coef. = - .004, SE = .002; z = - 2.0; p = .03) and the Aroian (coef. = - .004, SE = .002; z = - 1.9; p = .03) tests demonstrated that WBC mediated the relationship between physical activity and PSA. Additionally, among 107 participants with prostate cancer, survivors engaging in more MVPA had lower levels of WBC (b = - .04; 95% CI [ - 0.09, - 0.0009; p = .04). Conclusion Physical activity may influence PSA levels through WBC modulation; however, future research is needed to determine the direction of causality. Additionally, prostate cancer survivors engaging in higher levels of MVPA had lower levels of WBC, underscoring the importance of promoting physical activity among prostate cancer survivors.

  2. The Relationship Between the Gensini Score and Complete Blood Count Parameters in Coronary Artery Disease

    Directory of Open Access Journals (Sweden)

    Muhammet Raşit Sayın

    2012-08-01

    Full Text Available Introduction: The aim of this study was to evaluate the relationship between the extend andseverity of coronary artery disease (CAD determined by the Gensini score and complete bloodcount parameters (white blood cell, hemoglobin, platelet, mean platelet volume, lymphocyte,neutrophil.Patients and Methods: Ninety patients with CAD underwent coronary angiography (40 females,mean age 61 ± 1.2 years were included in this study. Patients with acute coronary syndrome andprior cardiovascular disease excluded from the study. The association between the extent andseverity of CAD, which were assessed by the Gensini score, and complete blood count parameterswas analyzed by a correlation analysis.Results: Coronary angiography revealed, 6 (6.7% patients had three, 16 (17.8% patients hadtwo, and 24 (26.7% patients had single-vessel disease; 44 (48.9% patients had non-criticalstenosis. The mean Gensini score was 19.1 ± 2.1. We found a relationship between white bloodcell and neutrophil counts and the Gensini score. There was no relationship between Gensiniscore and the mean platelet volume and other parameters.Conclusion: The present study supports the hypothesis that inflammation is one of the maincomponent in the pathogenesis of CAD.

  3. Effect of exercise on erythrocyte count and blood activity concentration after /sup 99m/Tc in vivo red blood cell labeling

    International Nuclear Information System (INIS)

    Konstam, M.A.; Tu'meh, S.; Wynne, J.; Beck, J.R.; Kozlowski, J.; Holman, B.L.

    1982-01-01

    We studied the effect of exercise on blood radiotracer concentration after /sup 99m/Tc in vivo red blood cell labeling. After red blood cell labeling, 13 subjects underwent maximal supine bicycle exercise. Radioactivity, analyzed with a well counter, was measured in heparinized venous blood samples drawn at rest and during peak exercise. Changes in activity were compared with changes in erythrocyte count. Activity and erythrocyte counts increased during exercise in all 13 subjects. Percent increase in activity correlated with percent increase in erythrocyte count (r . -0.78), but did not correlate with either duration of exercise or maximal heart rate. Twenty minutes after termination of exercise, activity and erythrocyte count had decreased from peak exercise values but remained higher than preexercise values. In nine nonexercised control subjects, samples drawn 20 minutes apart showed no change in activity or in erythrocyte count. We conclude that exercise increases blood activity, primarily because of an increase in erythrocyte count. During radionuclide ventriculography, blood activity must be measured before and after any intervention, particularly exercise, before a change in left ventricular activity can be attributed to a change in left ventricular volume

  4. Measurement of regional cerebral blood flow using one-point arterial blood sampling and microsphere model with 123I-IMP. Correction of one-point arterial sampling count by whole brain count ratio

    International Nuclear Information System (INIS)

    Makino, Kenichi; Masuda, Yasuhiko; Gotoh, Satoshi

    1998-01-01

    The experimental subjects were 189 patients with cerebrovascular disorders. 123 I-IMP, 222 MBq, was administered by intravenous infusion. Continuous arterial blood sampling was carried out for 5 minutes, and arterial blood was also sampled once at 5 minutes after 123 I-IMP administration. Then the whole blood count of the one-point arterial sampling was compared with the octanol-extracted count of the continuous arterial sampling. A positive correlation was found between the two values. The ratio of the continuous sampling octanol-extracted count (OC) to the one-point sampling whole blood count (TC5) was compared with the whole brain count ratio (5:29 ratio, Cn) using 1-minute planar SPECT images, centering on 5 and 29 minutes after 123 I-IMP administration. Correlation was found between the two values. The following relationship was shown from the correlation equation. OC/TC5=0.390969 x Cn-0.08924. Based on this correlation equation, we calculated the theoretical continuous arterial sampling octanol-extracted count (COC). COC=TC5 x (0.390969 x Cn-0.08924). There was good correlation between the value calculated with this equation and the actually measured value. The coefficient improved to r=0.94 from the r=0.87 obtained before using the 5:29 ratio for correction. For 23 of these 189 cases, another one-point arterial sampling was carried out at 6, 7, 8, 9 and 10 minutes after the administration of 123 I-IMP. The correlation coefficient was also improved for these other point samplings when this correction method using the 5:29 ratio was applied. It was concluded that it is possible to obtain highly accurate input functions, i.e., calculated continuous arterial sampling octanol-extracted counts, using one-point arterial sampling whole blood counts by performing correction using the 5:29 ratio. (K.H.)

  5. Correlation of circulating MMP-9 with white blood cell count in humans: effect of smoking.

    Directory of Open Access Journals (Sweden)

    Soren Snitker

    Full Text Available Matrix metalloproteinase-9 (MMP-9 is an emerging biomarker for several disease conditions, where white blood cell (WBC count is also elevated. In this study, we examined the relationship between MMP-9 and WBC levels in apparently healthy smoking and non-smoking human subjects.We conducted a cross-sectional study to assess the relationship of serum MMP-9 with WBC in 383 men and 356 women. Next, we divided the male population (women do not smoke in this population into three groups: never (n = 243, current (n = 76 and former (n = 64 smokers and compared the group differences in MMP-9 and WBC levels and their correlations within each group.Circulating MMP-9 and WBC count are significantly correlated in men (R(2 = 0.13, p<0.001 and women (R(2 = 0.19, p<0.001. After stratification by smoking status, MMP-9 level was significantly higher in current smokers (mean ± SE; 663.3±43.4 ng/ml, compared to never (529.7±20.6 and former smokers (568±39.3. WBC count was changed in a similar pattern. Meanwhile, the relationship became stronger in current smokers with increased correlation coefficient of r = 0.45 or R(2 = 0.21 (p<0.001 and steeper slope of ß = 1.16±0.30 (p<0.001 in current smokers, compared to r = 0.26 or R(2 = 0.07 (p<0.001 and ß = 0.34±0.10 (p<0.001 in never smokers.WBC count accounts for 13% and 19% of MMP-9 variance in men and women, respectively. In non-smoking men, WBC count accounts for 7% of MMP-9 variance, but in smoking subjects, it accounts for up to 21% of MMP-9 variance. Thus, we have discovered a previously unrecognized correlation between the circulating MMP-9 and WBC levels in humans.

  6. Blood count and number of somatic cells in milk of cows infected with Coxiella burnetii

    Directory of Open Access Journals (Sweden)

    Radinović Miodrag

    2011-01-01

    Full Text Available The objective of the work was to examine the intensity of the local immune response of the mammary gland and the changes in the differential blood count of chronically infected cows. An experiment was performed on a group of cows with Q fever serologically proven using the ELISA test (IDEXX. Based on the ELISA test results, an experimental group of ten infected cows was formed. Blood was sampled from the experimental cows, and cumulative milk samples were taken. The number of erythrocytes was determined spectrophotometrically, and the number of leucocytes using the method according to Bürker - Türk. The blood analysis established an increased number of erythrocytes, while the number of leucocytes was within the limits of physiological values. The milk samples were used for the determination of the number of somatic cells using flow cytometric measurements. The processing of the milk samples established an average number of somatic cells of 853.000 /mL milk.

  7. Determination of reference ranges for full blood count parameters in neonatal cord plasma in Hilla, Babil, Iraq

    Directory of Open Access Journals (Sweden)

    Al-Marzoki JM

    2012-10-01

    Full Text Available Jasim M Al-Marzoki1, Zainab W Al-Maaroof2, Ali H Kadhum31Department of Pediatrics, 2Department of Pathology, Babylon Medical College, 3Babylon Gynecology and Pediatric Teaching Hospital, Hilla, IraqBackground: The health of an individual is known to vary in different countries, in the same country at different times, and in the same individuals at different ages. This means that the condition of individuals must be related to or compared with reference data. Determination of a reference range for the healthy term newborn is clinically important in terms of various complete blood count parameters. The purpose of this study was to establish a local reference range for full blood count parameters in neonatal cord plasma in Hilla, Babil, Iraq.Methods: A total of 220 mothers and their neonates were enrolled in this cross-sectional study from February 2011 to January 2012. Maternal inclusion criteria were age 15–45 years, an uneventful pregnancy, and hemoglobin ≥ 10 g. Neonatal inclusion criteria were full term (37–42 weeks and normal birth weight. The umbilical cord was immediately clamped after delivery of the baby; 3 mL of cord blood was then taken from the umbilical vein and collected in a tube containing ethylenediamine tetra-acetic acid, its plasma was analyzed for full blood count parameters by standard Coulter gram, and the differential leukocyte count was done manually.Results: Mean neonatal hemoglobin was 13.88 ± 1.34 (range 11–17.3 g/dL and mean white cell count was 10.12 ± 2.8 (range 3.1–21.6 × 109/L. Mean platelet count was 267.63 ± 60.62 (range 152–472 × 109/L. No significant differences in red cell, white cell, or platelet counts were found between males and females, except for neutrophil count. The current study shows lower levels of hemoglobin, white cells, and red cells compared with other studies, and there is agreement with some studies and disagreement with others concerning platelet count.Conclusion: Most results

  8. The effect of manual acupuncture on blood neutrophil counts in moderate intensity exercise

    Science.gov (United States)

    Ciang, C. Y.; Simadibrata, C.; Tobing, A.; Srilestari, A.

    2017-08-01

    Exercise, even though it has a beneficial effect, can cause muscle damage and trigger inflammatory responses, as evidenced by increased neutrophils in the blood. Acupuncture is a therapeutic modality that is expected to reduce acute inflammatory responses due to exercise. Thirty untrained men were divided randomly into two groups. The manual acupuncture group (n = 15) received stimulation at acupoints ST36 and SP6 bilateral by needle insertion, while the placebo group (n = 15) received insertion of needles on plaster without penetrating the skin. Therapy was done once for 30 minutes immediately after the subjects completed the exercise. Blood neutrophil counts were assessed before exercise and one hour after exercise ended. The results show there is a statistically significant difference in the number of neutrophils before and after exercise between the manual acupuncture group and the placebo group (0.08±0.91 and 0.97±0.70 p = 0.006). Acupuncture therapy effectively mitigates the acute inflammatory response triggered by exercise.

  9. Fatigue, serum cytokine levels, and blood cell counts during radiotherapy of patients with breast cancer

    International Nuclear Information System (INIS)

    Geinitz, Hans; Zimmermann, Frank B.; Stoll, Peter; Thamm, Reinhard; Kaffenberger, Walter; Ansorg, Kai; Keller, Monika; Busch, Raymonde; Beuningen, Dirk van; Molls, Michael

    2001-01-01

    Purpose: To assess the level of fatigue during the course of adjuvant radiotherapy (RT) of breast cancer patients and its relation to anxiety, depression, serum cytokines, and blood count levels. Methods and Materials: Forty-one patients who received adjuvant RT after breast-conserving surgery were prospectively studied. All patients underwent RT without concomitant chemotherapy. Patients rated their fatigue with two standardized self-assessment instruments, the Fatigue Assessment Questionnaire and a visual analog scale on fatigue intensity, before RT, during weeks 1-5 of RT, and 2 months after RT completion. In addition, the anxiety and depression levels were assessed with the Hospital Anxiety and Depression Scale. A differential blood cell count and the serum levels of the cytokines interleukin (IL)-1β, IL-6, and tumor necrosis factor-α were determined in parallel to the fatigue assessments. Results: Fatigue intensity as assessed with the visual analog scale increased (p<0.001) until treatment week 4 and remained elevated until week 5. Two months after RT, the values had fallen to the pretreatment levels. Fatigue measured with the Fatigue Assessment Questionnaire did not increase significantly during treatment, but the subscores on physical (p=0.035) and cognitive (p=0.015) fatigue were elevated during treatment weeks 4 and 5. Affective fatigue did not change significantly. Anxiety, as rated with the Hospital Anxiety and Depression Scale, declined during RT (p=0.002), but the Hospital Anxiety and Depression Scale depression score did not change significantly. IL-1β, IL-6, and tumor necrosis factor-α levels did not change during therapy and did not correlate with fatigue. Peripheral blood cell levels declined significantly during therapy and were still low 2 months after treatment. Until treatment week 5, lymphocytes were reduced to almost 50% of their initial values. Hemoglobin levels did not correlate with fatigue. Conclusions: We observed an increase in

  10. Hemoglobin, red blood cell count, hematocrit and derived parameters for diagnosing anemia in elderly males

    International Nuclear Information System (INIS)

    Khan, Z.; Nawaz, M.

    2013-01-01

    Anemia is one of the most common micronutrient deficiency in our community. Nutritional anaemias are caused when there is an inadequate body store of a specific nutrient needed for hemoglobin synthesis. The most common nutrient deficiency is of iron. Therefore, a cross-sectional survey was conducted on the healthy elderly male, aged >= 40 and 77 years (n=60) volunteers in order to assess their blood parameters, such as hemoglobin concentration (Hb), hematocrit (HCT), red blood cell count (RBC), mean corpuscular volume (MCV), mean corpuscular hemoglobin (MCH) and mean corpuscular hemoglobin concentration (MCHC) for the diagnosis of anemia. The demographic results showed mean values (50.10+-8.79) years for age, 66-68 +- 1.95 inches for height , 71.43 +- 6.43 kg body weight, 98.34+-0.48 degree F body temperature, 124 +- 8.67 systolic blood pressure, 82.17 +- 4.15 diastolic pressure while, The pulse rate was found to be 74.63 +- 7.02/minute. Similarly, mean values for lean body weight (LBW) found to be 49.9+-2.89, ideal body weight (IBW) 60.9 +- 4.49, body surface area (BSA) was 1.8 +- 0.1 m2 whereas, body mass index (BMI) showed mean value 24.9 +- 2.6 kg/m2. More so, overall mean Hb found to be 13.60 g/dl, RBC 4.6 mill/mm3, HCT/PCV 43%, MCV 92.95fl, MCH 29.42 pg and MCHC was found to be 31.73 g/dl. The normal range of Hb for men was 13-17 g/dl and 31.67% of the subjects participated in the study was considered to be anemic showing less Hb than normal range. The volunteers were suggested to improve the dietary habits and to take iron supplements in order to overcome the iron deficiency anemia. (author)

  11. Straw blood cell count, growth, inhibition and comparison to apoptotic bodies

    Directory of Open Access Journals (Sweden)

    Tomkins Jeffrey P

    2008-05-01

    Full Text Available Abstract Background Mammalian cells transform into individual tubular straw cells naturally in tissues and in response to desiccation related stress in vitro. The transformation event is characterized by a dramatic cellular deformation process which includes: condensation of certain cellular materials into a much smaller tubular structure, synthesis of a tubular wall and growth of filamentous extensions. This study continues the characterization of straw cells in blood, as well as the mechanisms of tubular transformation in response to stress; with specific emphasis placed on investigating whether tubular transformation shares the same signaling pathway as apoptosis. Results There are approximately 100 billion, unconventional, tubular straw cells in human blood at any given time. The straw blood cell count (SBC is 45 million/ml, which accounts for 6.9% of the bloods dry weight. Straw cells originating from the lungs, liver and lymphocytes have varying nodules, hairiness and dimensions. Lipid profiling reveals severe disruption of the plasma membrane in CACO cells during transformation. The growth rates for the elongation of filaments and enlargement of rabbit straw cells is 0.6~1.1 (μm/hr and 3.8 (μm3/hr, respectively. Studies using apoptosis inhibitors and a tubular transformation inhibitor in CACO2 cells and in mice suggested apoptosis produced apoptotic bodies are mediated differently than tubular transformation produced straw cells. A single dose of 0.01 mg/kg/day of p38 MAPK inhibitor in wild type mice results in a 30% reduction in the SBC. In 9 domestic animals SBC appears to correlate inversely with an animal's average lifespan (R2 = 0.7. Conclusion Straw cells are observed residing in the mammalian blood with large quantities. Production of SBC appears to be constant for a given animal and may involve a stress-inducible protein kinase (P38 MAPK. Tubular transformation is a programmed cell survival process that diverges from apoptosis

  12. Peripheral blood CD34+ cell count as a predictor of adequacy of hematopoietic stem cell collection for autologous transplantation

    Directory of Open Access Journals (Sweden)

    Combariza, Juan F.

    2016-10-01

    Full Text Available Introduction: In order to carry out an autologous transplantation, hematopoietic stem cells should be mobilized to peripheral blood and later collected by apheresis. The CD34+ cell count is a tool to establish the optimal time to begin the apheresis procedure. Objective: To evaluate the association between peripheral blood CD34+ cell count and the successful collection of hematopoietic stem cells. Materials and methods: A predictive test evaluation study was carried out to establish the usefulness of peripheral blood CD34+ cell count as a predictor of successful stem cell collection in patients that will receive an autologous transplantation. Results: 77 patients were included (median age: 49 years; range: 5-66. The predominant baseline diagnosis was lymphoma (53.2 %. The percentage of patients with successful harvest of hematopoietic stem cells was proportional to the number of CD34+cells in peripheral blood at the end of the mobilization procedure. We propose that more than 15 CD34+cells/μL must be present in order to achieve an adequate collection of hematopoietic stem cells. Conclusion: Peripheral blood CD34+ cell count is a useful tool to predict the successful collection of hematopoietic stem cells.

  13. Predictive Value of Nucleated Red Blood Cell Counts in Cord and Peripheral Blood of Asphyxiated Term Neonates in the First Week of Life

    Directory of Open Access Journals (Sweden)

    B Bahman Bijari

    2010-03-01

    Full Text Available Introduction: Increased numbers of nucleated red blood cells (NRBC circulating in the blood of neonates can be associated with relative hypoxia and adverse outcomes. Thus, the aim of this study was to assess the NRBC count during the first week of life in neonates diagnosed with asphyxia as compared to healthy neonates and to determine the short-term morbidity and mortality for the affected babies. Methods: The cross-sectional study compared 15 healthy neonates with 15 neonates diagnosed with asphyxia confirmed by pH of cord blood or Apgar scores. The nucleated red blood cell (NRBC counts were calculated right after birth, and on days 3 and 7, and the hematological parameters of umbilical cord blood were also evaluated. The infants were followed for mortality and associated morbidity. Statistical analysis was conducted using the Mann-Whitney U test, analysis of variance, chi-square tests, and Pearson’s correlation coefficient. A p-value < 0.05 was considered as statistically significant. Results: The initial NRBC counts were significantly higher in the asphyxiated group than in the control group and the difference remained significant through the end of first week. All of the umbilical cord blood parameters were significantly lower in the study group and were negatively correlated with the NRBC count. At birth, higher NRBC count correlated with higher mortality. conclution: Results show that NRBC count is a useful predictive factor for neonatal asphyxia through the end of the first week of life, although a larger study population and a longer follow up period seems to be necessary.

  14. Intravenous Tissue Plasminogen Activator Can Be Safely Given without Complete Blood Count Results Back.

    Directory of Open Access Journals (Sweden)

    Yi Dong

    Full Text Available It is well known that the efficacy of intravenous (i.v. tissue plasminogen activator (tPA is time-dependent when used to treat patients with acute ischemic strokes.Our study examines the safety issue of giving IV tPA without complete blood count (CBC resulted.This is a retrospective observational study by examining the database from Huashan Hospital in China and OSF/INI Comprehensive Stroke Center in United States. Patient data collected included demographics, occurrence of symptomatic intracranial hemorrhage, door to needle intervals, National Institute of Health Stroke Scale scores on admission, CBC results on admission and follow-up modified Rankin Scale scores. Linear regression and multivariable logistic regression analysis were used to identify factors that would have an impact on door-to-needle intervals.Our study included 120 patients from Huashan Hospital and 123 patients from INI. Among them, 36 in Huashan Hospital and 51 in INI received i.v. tPA prior to their CBC resulted. Normal platelet count was found in 98.8% patients after tPA was given. One patient had thrombocytopenia but no hemorrhagic event. A significantly shorter door to needle interval (DTN was found in the group without CBC resulted. There was also a difference in treatment interval between the two hospitals. Door to needle intervals had a strong correlation to onset to treatment intervals and NIHSS scores on admission.In patients presented with acute ischemic stroke, the risk of developing hemorrhagic event is low if i.v. tPA is given before CBC has resulted. The door to needle intervals can be significantly reduced.

  15. A Novel Automated Slide-Based Technology for Visualization, Counting, and Characterization of the Formed Elements of Blood: A Proof of Concept Study.

    Science.gov (United States)

    Winkelman, James W; Tanasijevic, Milenko J; Zahniser, David J

    2017-08-01

    - A novel automated slide-based approach to the complete blood count and white blood cell differential count is introduced. - To present proof of concept for an image-based approach to complete blood count, based on a new slide preparation technique. A preliminary data comparison with the current flow-based technology is shown. - A prototype instrument uses a proprietary method and technology to deposit a precise volume of undiluted peripheral whole blood in a monolayer onto a glass microscope slide so that every cell can be distinguished, counted, and imaged. The slide is stained, and then multispectral image analysis is used to measure the complete blood count parameters. Images from a 600-cell white blood cell differential count, as well as 5000 red blood cells and a variable number of platelets, that are present in 600 high-power fields are made available for a technologist to view on a computer screen. An initial comparison of the basic complete blood count parameters was performed, comparing 1857 specimens on both the new instrument and a flow-based hematology analyzer. - Excellent correlations were obtained between the prototype instrument and a flow-based system. The primary parameters of white blood cell, red blood cell, and platelet counts resulted in correlation coefficients (r) of 0.99, 0.99, and 0.98, respectively. Other indices included hemoglobin (r = 0.99), hematocrit (r = 0.99), mean cellular volume (r = 0.90), mean corpuscular hemoglobin (r = 0.97), and mean platelet volume (r = 0.87). For the automated white blood cell differential counts, r values were calculated for neutrophils (r = 0.98), lymphocytes (r = 0.97), monocytes (r = 0.76), eosinophils (r = 0.96), and basophils (r = 0.63). - Quantitative results for components of the complete blood count and automated white blood cell differential count can be developed by image analysis of a monolayer preparation of a known volume of peripheral blood.

  16. Radiological features of pulmonary tuberculosis in human immunodeficiency virus-infected patients: correlation with the blood CD4 cell count

    International Nuclear Information System (INIS)

    Isusi, M.; Eguidazu, J.; Oleaga, L.; Grande, D.

    2000-01-01

    To describe the radiological features of pulmonary tuberculosis (TB) in patients infected with human immunodeficiency virus (HIV) and its correlation with the blood CD4 cell count. We present 44 HIV+patients, 24 with CD4 cell counts of less than 200 cells/mm''3 (group A) and 20 in whom the CD4 counts surpassed this level (group B). We also assessed the chest x-ray images to determine whether or not there was any correlation with the blood CD4 cell counts. Fisher's exact test was used for the statistical study of the differences in the radiological findings in the two groups. The incidence of atypical features was significantly greater in the patients with CD4 cell counts of less than 200 cells/mm''3 (group A) than in those with CD4 counts of over 200 cells/mm''3 (group B). Among HIV+patients, those with a more intact immune status were more likely to present lung x-ray images typical of post-primary TB, with cavitary lesions in upper lobes. The group of patients in whom the immune deficiency was more marked showed a greater incidence of atypical pulmonary findings, more characteristics of primary TB. (Author)

  17. Determination of reference ranges for full blood count parameters in neonatal cord plasma in Hilla, Babil, Iraq

    Science.gov (United States)

    Al-Marzoki, Jasim M; Al-Maaroof, Zainab W; Kadhum, Ali H

    2012-01-01

    Background The health of an individual is known to vary in different countries, in the same country at different times, and in the same individuals at different ages. This means that the condition of individuals must be related to or compared with reference data. Determination of a reference range for the healthy term newborn is clinically important in terms of various complete blood count parameters. The purpose of this study was to establish a local reference range for full blood count parameters in neonatal cord plasma in Hilla, Babil, Iraq. Methods A total of 220 mothers and their neonates were enrolled in this cross-sectional study from February 2011 to January 2012. Maternal inclusion criteria were age 15–45 years, an uneventful pregnancy, and hemoglobin ≥ 10 g. Neonatal inclusion criteria were full term (37–42 weeks) and normal birth weight. The umbilical cord was immediately clamped after delivery of the baby; 3 mL of cord blood was then taken from the umbilical vein and collected in a tube containing ethylenediamine tetra-acetic acid, its plasma was analyzed for full blood count parameters by standard Coulter gram, and the differential leukocyte count was done manually. Results Mean neonatal hemoglobin was 13.88 ± 1.34 (range 11–17.3) g/dL and mean white cell count was 10.12 ± 2.8 (range 3.1–21.6) × 109/L. Mean platelet count was 267.63 ± 60.62 (range 152–472) × 109/L. No significant differences in red cell, white cell, or platelet counts were found between males and females, except for neutrophil count. The current study shows lower levels of hemoglobin, white cells, and red cells compared with other studies, and there is agreement with some studies and disagreement with others concerning platelet count. Conclusion Most results in the current study were within the reference range. The hematological reference values for Iraqi neonatal cord plasma need to be confirmed by larger numbers of blood samples and by collecting samples from

  18. Total white blood cell counts and LPS-induced TNF alpha production by monocytes of pregnant, pseudopregnant and cyclic rats

    NARCIS (Netherlands)

    Faas, MM; Moes, H; van der Schaaf, G; de Leij, LFMH; Heineman, MJ

    Pregnancy in the rat may be associated with an activated innate immune system. Therefore, we investigated monocyte function as well as total white blood cell (WBC) counts during the follicular phase of the ovarian cycle, pregnancy and pseudopregnancy in the rat. Rats were equipped with a permanent

  19. Total white blood cell counts and LPS-induced TNF alpha production by monocytes of pregnant, pseudopregnant and cyclic rats

    NARCIS (Netherlands)

    Faas, M. M.; Moes, H.; van der Schaaf, G.; de Leij, L. F. M. H.; Heineman, M. J.

    2003-01-01

    Pregnancy in the rat may be associated with an activated innate immune system. Therefore, we investigated monocyte function as well as total white blood cell (WBC) counts during the follicular phase of the ovarian cycle, pregnancy and pseudopregnancy in the rat. Rats were equipped with a permanent

  20. The Preoperative Peripheral Blood Monocyte Count Is Associated with Liver Metastasis and Overall Survival in Colorectal Cancer Patients.

    Directory of Open Access Journals (Sweden)

    Shidong Hu

    Full Text Available Colorectal cancer (CRC is the third most common malignancy in males and the second most common in females worldwide. Distant metastases have a strong negative impact on the prognosis of CRC patients. The most common site of CRC metastases is the liver. Both disease progression and metastasis have been related to the patient's peripheral blood monocyte count. We therefore performed a case-control study to assess the relationship between the preoperative peripheral blood monocyte count and colorectal liver metastases (CRLM.Clinical data from 117 patients with colon cancer and 93 with rectal cancer who were admitted to the Chinese People's Liberation Army General Hospital (Beijing, China between December 2003 and May 2015 were analysed retrospectively, with the permission of both the patients and the hospital.Preoperative peripheral blood monocyte counts, the T and N classifications of the primary tumour and its primary site differed significantly between the two groups (P 0.505 × 109 cells/L, high T classification and liver metastasis were independent risk factors for 5-year OS (RR: 2.737, 95% CI: 1.573~ 4.764, P <0.001; RR: 2.687, 95%CI: 1.498~4.820, P = 0.001; RR: 4.928, 95%CI: 2.871~8.457, P < 0.001.The demonstrated association between preoperative peripheral blood monocyte count and liver metastasis in patients with CRC recommends the former as a useful predictor of postoperative prognosis in CRC patients.

  1. Effect of anabolic steroid on the recovery of white blood cell count after irradiation

    International Nuclear Information System (INIS)

    Yamagishi, Motohisa; Niki, Takamichi; Hiraoka, Atsunobu; Uchino, Haruto

    1979-01-01

    In order to observe the effects of nandrolone decanoate (NAN-D), an anabolic steroid, on granulocytes, its effect on the recovery of white blood cells (WBC) and granulocytes after radiation injuries was studied. Male mice were irradiated with 405 to 410 R of γ rays, and a 2.5 mg/dose of NAN-D was given subcutaneously 6 to 7 days after irradiation (group I) or immediately after irradiation (group II). The degree of decrease in WBC after irradiation was the same in both groups, but the recovery of WBC 18 days after irradiation was marked in group II, the control group, and group I, respectively. The recovery of granulocytes was the most marked in group II and was more marked in group I than in the control group. In an experiment in which NAN-D was given 2 to 3 days before irradiation (group III), WBC showed higher values in group III than in the control group 9 days after irradiation. The difference in WBC between group III and the control group was the greatest 17 days after irradiation. A gross count of granulocyte precursor cells in one femur clearly increased in the groups given this agent. (Tsunoda, M.)

  2. Flow cytometric assessment of activation of peripheral blood platelets in dogs with normal platelet count and asymptomatic thrombocytopenia.

    Science.gov (United States)

    Żmigrodzka, M; Guzera, M; Winnicka, A

    2016-01-01

    Platelets play a crucial role in hemostasis. Their activation has not yet been evaluated in healthy dogs with a normal and low platelet count. The aim of this study was to determine the influence of activators on platelet activation in dogs with a normal platelet count and asymptomatic thrombocytopenia. 72 clinically healthy dogs were enrolled. Patients were allocated into three groups. Group 1 consisted of 30 dogs with a normal platelet count, group 2 included 22 dogs with a platelet count between 100 and 200×109/l and group 3 consisted of 20 dogs with a platelet count lower than 100×109/l. Platelet rich-plasma (PRP) was obtained from peripheral blood samples using tripotassium ethylenediaminetetraacetic acid (K3-EDTA) as anticoagulant. Next, platelets were stimulated using phorbol-12-myristate-13-acetate or thrombin, stabilized using procaine or left unstimulated. The expression of CD51 and CD41/CD61 was evaluated. Co-expression of CD41/CD61 and Annexin V served as a marker of platelet activation. The expression of CD41/CD61 and CD51 did not differ between the 3 groups. Thrombin-stimulated platelets had a significantly higher activity in dogs with a normal platelet count than in dogs with asymptomatic thrombocytopenia. Procaine inhibited platelet activity in all groups. In conclusion, activation of platelets of healthy dogs in vitro varied depending on the platelet count and platelet activator.

  3. White blood cell differential count of maturation stages in bone marrow smear using dual-stage convolutional neural networks.

    Science.gov (United States)

    Choi, Jin Woo; Ku, Yunseo; Yoo, Byeong Wook; Kim, Jung-Ah; Lee, Dong Soon; Chai, Young Jun; Kong, Hyoun-Joong; Kim, Hee Chan

    2017-01-01

    The white blood cell differential count of the bone marrow provides information concerning the distribution of immature and mature cells within maturation stages. The results of such examinations are important for the diagnosis of various diseases and for follow-up care after chemotherapy. However, manual, labor-intensive methods to determine the differential count lead to inter- and intra-variations among the results obtained by hematologists. Therefore, an automated system to conduct the white blood cell differential count is highly desirable, but several difficulties hinder progress. There are variations in the white blood cells of each maturation stage, small inter-class differences within each stage, and variations in images because of the different acquisition and staining processes. Moreover, a large number of classes need to be classified for bone marrow smear analysis, and the high density of touching cells in bone marrow smears renders difficult the segmentation of single cells, which is crucial to traditional image processing and machine learning. Few studies have attempted to discriminate bone marrow cells, and even these have either discriminated only a few classes or yielded insufficient performance. In this study, we propose an automated white blood cell differential counting system from bone marrow smear images using a dual-stage convolutional neural network (CNN). A total of 2,174 patch images were collected for training and testing. The dual-stage CNN classified images into 10 classes of the myeloid and erythroid maturation series, and achieved an accuracy of 97.06%, a precision of 97.13%, a recall of 97.06%, and an F-1 score of 97.1%. The proposed method not only showed high classification performance, but also successfully classified raw images without single cell segmentation and manual feature extraction by implementing CNN. Moreover, it demonstrated rotation and location invariance. These results highlight the promise of the proposed method

  4. White blood cell differential count of maturation stages in bone marrow smear using dual-stage convolutional neural networks

    Science.gov (United States)

    Choi, Jin Woo; Ku, Yunseo; Yoo, Byeong Wook; Kim, Jung-Ah; Lee, Dong Soon; Chai, Young Jun; Kong, Hyoun-Joong

    2017-01-01

    The white blood cell differential count of the bone marrow provides information concerning the distribution of immature and mature cells within maturation stages. The results of such examinations are important for the diagnosis of various diseases and for follow-up care after chemotherapy. However, manual, labor-intensive methods to determine the differential count lead to inter- and intra-variations among the results obtained by hematologists. Therefore, an automated system to conduct the white blood cell differential count is highly desirable, but several difficulties hinder progress. There are variations in the white blood cells of each maturation stage, small inter-class differences within each stage, and variations in images because of the different acquisition and staining processes. Moreover, a large number of classes need to be classified for bone marrow smear analysis, and the high density of touching cells in bone marrow smears renders difficult the segmentation of single cells, which is crucial to traditional image processing and machine learning. Few studies have attempted to discriminate bone marrow cells, and even these have either discriminated only a few classes or yielded insufficient performance. In this study, we propose an automated white blood cell differential counting system from bone marrow smear images using a dual-stage convolutional neural network (CNN). A total of 2,174 patch images were collected for training and testing. The dual-stage CNN classified images into 10 classes of the myeloid and erythroid maturation series, and achieved an accuracy of 97.06%, a precision of 97.13%, a recall of 97.06%, and an F-1 score of 97.1%. The proposed method not only showed high classification performance, but also successfully classified raw images without single cell segmentation and manual feature extraction by implementing CNN. Moreover, it demonstrated rotation and location invariance. These results highlight the promise of the proposed method

  5. White blood cell differential count of maturation stages in bone marrow smear using dual-stage convolutional neural networks.

    Directory of Open Access Journals (Sweden)

    Jin Woo Choi

    Full Text Available The white blood cell differential count of the bone marrow provides information concerning the distribution of immature and mature cells within maturation stages. The results of such examinations are important for the diagnosis of various diseases and for follow-up care after chemotherapy. However, manual, labor-intensive methods to determine the differential count lead to inter- and intra-variations among the results obtained by hematologists. Therefore, an automated system to conduct the white blood cell differential count is highly desirable, but several difficulties hinder progress. There are variations in the white blood cells of each maturation stage, small inter-class differences within each stage, and variations in images because of the different acquisition and staining processes. Moreover, a large number of classes need to be classified for bone marrow smear analysis, and the high density of touching cells in bone marrow smears renders difficult the segmentation of single cells, which is crucial to traditional image processing and machine learning. Few studies have attempted to discriminate bone marrow cells, and even these have either discriminated only a few classes or yielded insufficient performance. In this study, we propose an automated white blood cell differential counting system from bone marrow smear images using a dual-stage convolutional neural network (CNN. A total of 2,174 patch images were collected for training and testing. The dual-stage CNN classified images into 10 classes of the myeloid and erythroid maturation series, and achieved an accuracy of 97.06%, a precision of 97.13%, a recall of 97.06%, and an F-1 score of 97.1%. The proposed method not only showed high classification performance, but also successfully classified raw images without single cell segmentation and manual feature extraction by implementing CNN. Moreover, it demonstrated rotation and location invariance. These results highlight the promise of

  6. Study on the peripheral white blood cell count in patients with type 2 diabetes complicated with microangiopathy

    International Nuclear Information System (INIS)

    Cai Wenpin; Zhu Pinghui

    2010-01-01

    Objective: To study the possible role played by peripheral white blood cells in the development of type 2 diabetes (DM2) and complication of microvascular pathological changes. Methods: White blood cell count and metabolism related parameters (FBG, 2hPBG, 2h Pinsulin, TCH, HDL, LDL, TG, HbA1c, BMI, age) were examined in 33 DM2 patients without complication, 41 DM2 patients with micro-angiopathy and 31 controls. Results: The white blood cell counts in both DM2 patients with no complication and the DM2 with microvascular pathological changes were significantly higher than those in controls (P 0.05). The white blood cell counts were positively correlated with age,body metabolism index (BMI), triglyceride (TG), 2h glucose (PBG) and 2h insulin (the r value 0.248, 0.201, 0.435, 0.225, 0.352 respectively, P<0.05). Conclusion: Peripheral white blood cells possibly played some role in development of DM2 and microvascular pathological changes and might be of some predictive importance. (authors)

  7. The impact of preapheresis white blood cell count on autologous peripheral blood stem cell collection efficiency and HSC infusion side effect rate.

    Science.gov (United States)

    Sakashita, Araci M; Kondo, Andrea T; Yokoyama, Ana Paula H; Lira, Sanny M C; Bub, Carolina B; Souza, Aline M; Cipolletta, Andrea N F; Alvarez, Kelen C; Hamerschlak, Nelson; Kutner, Jose M; Chiattone, Carlos S

    2018-01-19

    Autologous peripheral blood hematopoietic stem cell (PBSC) collection efficiency (CE) is reportedly affected by the patient's blood properties; however, studies to identify factors correlated with CE have shown inconsistent results. Additionally, variables such as stem cell graft granulocyte content and patient age, sex, and underlying disease, may be associated with hematopietic stem cell (HSC) infusion-related adverse reactions. In this study, we evaluated the correlation of preleukapheresis PB granulocyte count and PBSC harvest variables with CD34 + collection yield and efficiency, and thawed HSC infusion side effect occurrence. We evaluated data from 361 patients who had undergone autologous PBSC transplant. Large volume leukapheresis was the method for PBSC collection. Complete Blood Count and CD34 + cell enumeration were performed in the preapheresis PB and the apheresis product sample. The PBSC grafts were submitted to non-controlled rate freezing after addition of 5% DMSO plus 6% hidroxyethylstarch as a cryoprotectant solution. The cryopreserved graft was thawed in a 37°C water bath and then infused without further manipulation. The CD34 + yield was associated with preapheresis PB CD34 + count and immature granulocyte count. The PBSC CE was negatively correlated with preapheresis white blood cell (WBC), immature granulocyte and granulocyte count. The leukapheresis product total nucleated cell (TNC) and granulocyte content was correlated with the thawed graft infusion side effect occurrence. This study has shown that preapheresis PB WBC and granulocyte counts were associated with leukapheresis CE. Additionally, the leukapheresis product TNC and granulocyte content was correlated with thawed graft infusion side effect occurrence. © 2018 Wiley Periodicals, Inc.

  8. Three-dimensional counting of morphologically normal human red blood cells via digital holographic microscopy

    Science.gov (United States)

    Yi, Faliu; Moon, Inkyu; Lee, Yeon H.

    2015-01-01

    Counting morphologically normal cells in human red blood cells (RBCs) is extremely beneficial in the health care field. We propose a three-dimensional (3-D) classification method of automatically determining the morphologically normal RBCs in the phase image of multiple human RBCs that are obtained by off-axis digital holographic microscopy (DHM). The RBC holograms are first recorded by DHM, and then the phase images of multiple RBCs are reconstructed by a computational numerical algorithm. To design the classifier, the three typical RBC shapes, which are stomatocyte, discocyte, and echinocyte, are used for training and testing. Nonmain or abnormal RBC shapes different from the three normal shapes are defined as the fourth category. Ten features, including projected surface area, average phase value, mean corpuscular hemoglobin, perimeter, mean corpuscular hemoglobin surface density, circularity, mean phase of center part, sphericity coefficient, elongation, and pallor, are extracted from each RBC after segmenting the reconstructed phase images by using a watershed transform algorithm. Moreover, four additional properties, such as projected surface area, perimeter, average phase value, and elongation, are measured from the inner part of each cell, which can give significant information beyond the previous 10 features for the separation of the RBC groups; these are verified in the experiment by the statistical method of Hotelling's T-square test. We also apply the principal component analysis algorithm to reduce the dimension number of variables and establish the Gaussian mixture densities using the projected data with the first eight principal components. Consequently, the Gaussian mixtures are used to design the discriminant functions based on Bayesian decision theory. To improve the performance of the Bayes classifier and the accuracy of estimation of its error rate, the leaving-one-out technique is applied. Experimental results show that the proposed method can

  9. White blood cell count, absolute neutrophil count, as predictors of hidden bacterial infections in febrile children 1-18 months of age without focus

    International Nuclear Information System (INIS)

    AL-Majali, R.M.

    2004-01-01

    Objectives: To study the relationship between White Blood Cell (WBC), Absolute Neutrophil Count (ANC) in febrile children 1-18 months of age as predictor of bacterial infection, so as to improve our predictability of bacterial infections in emergency room to decrease unnecessary admissions and antibiotic use. Methods: Retrospective review was performed on febrile patients 1-18 months of age that were admitted to hospital between August 2002 and March 2003 on the presumptive diagnosis of fever without focus, Complete septic work up was done for all patients according to local hospital protocol including Complete blood count (CBC), blood culture, urine culture, Chest X-Ray (CXR) and lumbar puncture, Patients who had history of antibiotics use within 48 hours of admission were excluded from the study, History, physical examination, laboratory and radiology data were reviewed. Data about the age, sex, temperature, presence or absence of focal bacterial infection, WBC, ANC, CXR report and body fluid culture results were collected and analyzed. Results: Thirty-four patients were reviewed in this study, Eight patients (23.5%) had bacterial infection: classified as group (2 patchy pneumonia, 3 Urinary tract infection (UTI), 2 meningitis, 1 Occult bacteremia (OB) and 26 patients (76.5%) had no evidence of bacterial infection, classified as group 2, No significant difference was found between the two groups in respect to age, sex, temperature and WBC P>0.05, while there was a significant difference between the two groups in respect to the ANC P = 0.02, also ANC had better sensitivity (78%) and specificity (89%) than WBC (sensitivity 77%, specificity 62%). Conclusion: ANC is a good predictive test for determining bacterial infection in young febrile children without focus, However there is need for other more reliable rapid cost effective measures in dealing with young febrile children at emergency department. (author)

  10. Effect of number of cigarettes smoked per day on red blood cell, lecocyte and platelet count in adult Indian male smokers – A case control study

    Directory of Open Access Journals (Sweden)

    Bharati Anil Sherke

    2016-02-01

    Full Text Available The effects of cigarette smoking are fatal. Present study was done to compare cell counts of blood in males smoking different number of cigarettes per day and non smokers of Hyderabad city. 150 consenting subjects of which 30 controls (non-smokers and 120 cases (smokers were studied. Smokers were divided into four groups based on number of cigarettes smoked per day. Blood samples processed using Hematology analyser (ABX Micros60®, HORIBA, Kyoto, Japan. The smokers had significantly different red blood cell counts (p<0.0001, white blood cells counts (p<0.0001 including neutrophils, lymphocytes, monocytes and eosinophils. This effect was significant irrespective of the number of cigarettes. There was no significant change in the percentage of basophils and platelet counts. Conclusion: Our findings showed that cigarette smoking has a significant effect on hematological cell counts and these counts changed significantly with increasing number of cigarettes smoked per day.

  11. Complete Blood Count Reference Values of Cord Blood in Taiwan and the Influence of Gender and Delivery Route on Them

    Directory of Open Access Journals (Sweden)

    Yu-Hsun Chang

    2011-06-01

    Conclusion: We successfully obtained the normal CBC and WBC DC reference values of the cord blood in Taiwan. Gender and delivery routes were important confounding factors that influenced the cord blood CBC and WBC DC values.

  12. C-reactive protein and white blood cell count do not improve clinical decision-making in acute appendicitis

    DEFF Research Database (Denmark)

    Tind, Sofie; Lassen, Annmarie Touborg; Zimmermann-Nielsen, Erik

    2015-01-01

    INTRODUCTION: Acute appendicitis (AA) remains a diagnostic challenge as indicated by the high rate of unnecessary surgery. Blood samples, primarily C-reactive protein (CRP) and leucocyte counts, are used as a diagnostic supplement despite their relatively low sensitivities and specificities...... the blood results and re-evaluate their diagnosis. The surgeon's diagnosis before and after was compared with the final diagnosis defined by surgical findings or follow-up. The gold standard was any degree of appendicitis on histology. RESULTS: A total of 226 patients were included of whom 91 (40.3%) had...... appendicitis on histology. The surgeons changed their diagnosis in nine cases after assessing blood samples. The changes in the proportion of correct diagnoses, sensitivity, specificity and predictive values after assessing blood samples were not significant. CONCLUSIONS: The results of CRP and leucocyte...

  13. A comparative study on the blood and milk cell counts of healthy, subclinical and clinical mastitis Karan Fries cows

    Directory of Open Access Journals (Sweden)

    Mohanned Alhussien

    2015-05-01

    Full Text Available Aim: The present study was aimed to study the use of cell counts as an early indicator of mammary health. Materials and Methods: Milk and blood cell counts were estimated from 8 healthy, 8 subclinical (SCM, and 8 clinically mastitis (CM groups of Karan Fries (KF cows. Results: Total leucocyte counts and neutrophil percent in blood and milk somatic cells and milk neutrophil percent of healthy cows increased significantly (p<0.05 in SCM cows and CM cows. Viability of blood and milk neutrophils was more in healthy cows, but decreased significantly (p<0.05 in SCM and CM cows. Significant (p<0.05 decrease were also observed in both the blood and milk lymphocytes and monocytes of SCM and CM cows. Phagocytic activity (PA of blood neutrophils also decreased significantly (p<0.05 in SCM cows. There was no difference between the PA of SCM and CM cows. Milk neutrophil percent was more in the SCM and clinically infected milk than in the blood of these cows. About 96-97% of the neutrophils had segmented nucleus in both healthy and subclinical milk, whereas, 2-3% were having band shaped or immature nuclei. There was a significant decrease in the segmented neutrophils, whereas, band neutrophils increase significantly to about 5% in the infected milk of mastitic cows. Viability of the milk neutrophils decreased more in case of subclinical and clinical milk as compared to that of blood. PA was found to be highest in the milk of healthy group of cows, but decreased significantly (p<0.05 in subclinically infected cows. However, there was no difference between the PA of milk neutrophils of SCM and CM cows. PA of milk was also found to be significantly lower in the milk of healthy cows when compared to that of blood neutrophils. Conclusion: This study indicated that percent neutrophils and their type in conjunction with milk somatic cell counts can be used as a more reliable indicator of mammary health in cows.

  14. Development of a Prognostic Score Using the Complete Blood Cell Count for Survival Prediction in Unselected Critically Ill Patients

    OpenAIRE

    Chongliang, Fang; Yuzhong, Li; Qian, Shi; Xiliang, Liu; Hui, Liu

    2013-01-01

    Objective. The purpose of this study was to develop a new prognostic scoring system for critically ill patients using the simple complete blood cell count (CBC). Methods. CBC measurements in samples from 306 patients in an intensive care unit were conducted with automated analyzers, including levels of neutrophils, lymphocytes, erythrocytes, hemoglobin, and platelets. The time of sampling and the time of death were recorded. Z values were calculated according to the measured values, reference...

  15. The Preoperative Peripheral Blood Monocyte Count Is Associated with Liver Metastasis and Overall Survival in Colorectal Cancer Patients.

    Science.gov (United States)

    Hu, Shidong; Zou, Zhenyu; Li, Hao; Zou, Guijun; Li, Zhao; Xu, Jian; Wang, Lingde; Du, Xiaohui

    2016-01-01

    Colorectal cancer (CRC) is the third most common malignancy in males and the second most common in females worldwide. Distant metastases have a strong negative impact on the prognosis of CRC patients. The most common site of CRC metastases is the liver. Both disease progression and metastasis have been related to the patient's peripheral blood monocyte count. We therefore performed a case-control study to assess the relationship between the preoperative peripheral blood monocyte count and colorectal liver metastases (CRLM). Clinical data from 117 patients with colon cancer and 93 with rectal cancer who were admitted to the Chinese People's Liberation Army General Hospital (Beijing, China) between December 2003 and May 2015 were analysed retrospectively, with the permission of both the patients and the hospital. Preoperative peripheral blood monocyte counts, the T and N classifications of the primary tumour and its primary site differed significantly between the two groups (P colon cancer (OR: 0.078, 95%CI: 0.020~0.309, P 0.505 × 109 cells/L, high T classification and liver metastasis were independent risk factors for 5-year OS (RR: 2.737, 95% CI: 1.573~ 4.764, P <0.001; RR: 2.687, 95%CI: 1.498~4.820, P = 0.001; RR: 4.928, 95%CI: 2.871~8.457, P < 0.001). The demonstrated association between preoperative peripheral blood monocyte count and liver metastasis in patients with CRC recommends the former as a useful predictor of postoperative prognosis in CRC patients.

  16. The nutritional status affects the complete blood count of goats experimentally infected with Haemonchus contortus.

    Science.gov (United States)

    Cériac, S; Jayles, C; Arquet, R; Feuillet, D; Félicité, Y; Archimède, H; Bambou, J-C

    2017-11-09

    Gastrointestinal nematode (GIN) remains the most important pathogenic constraint of small ruminant production worldwide. The improvement of the host immune response against GIN though breeding for improved animal resistance, vaccination and nutritional supplementation appear as very promising methods. The objective of this study was to investigate the effect of four nutritional status differing in protein and energy levels (Hay: 5.1 MJ/Kg of dry matter (DM) and 7.6% of crude protein (CP), Ban: 8.3 MJ/Kg of DM and 7.5% of CP, Soy: 7.6 MJ/Kg of DM and 17.3% of CP, BS: 12.7 MJ/Kg of DM and 7.4% of CP) on the haematological disturbances due to Haemonchus contortus infection in Creole kid goats. No significant effect of the nutritional status was observed for faecal egg count (FEC) but the experimental infection induced haematological disturbances whose intensity and lengthening were dependent on the nutritional status. A transient marked regenerative macrocytic hypochromic anaemia as revealed by a decrease of packed cell volume (PCV), red blood cells (RBC) and hemoglobin and an increase of reticulocytes was observed in all infected groups except Hay. In this latter, the anaemia settled until the end of the experiment. Furthermore, H. contortus induced a thrombocytopenia significantly more pronounced in the group under the lowest nutritional status in term of protein (Hay and Ban). A principal component analysis revealed that the variables that discriminated the nutritional status were the average daily gain (ADG) and the PCV, considered as measures of the level of resilience to H. contortus infection. Moreover, the variables that discriminated infected and non-infected animals were mostly related to the biology of RBC (i.e. size and hemoglobin content) and they were correlated with FEC. The severity and the lengthening of the regenerative anaemia and the thrombocytopenia induced by H. contortus have been affected by the nutritional status. The protein enriched

  17. Nodal tumor response according to the count of peripheral blood lymphocyte subpopulations during preoperative chemoradiotherapy in locally advanced rectal cancer

    Energy Technology Data Exchange (ETDEWEB)

    Heo, Jae Sung; Oh, Young Tae; Noh, O Kyu; Chun, Mi Son; Park, Jun Eun; Cho, Sung Ran [Ajou University School of Medicine, Suwon (Korea, Republic of)

    2016-12-15

    The objective of this prospective study was to evaluate the relationship between the circulating lymphocyte subpopulation counts during preoperative chemoradiotherapy (CRT) and tumor response in locally advanced rectal cancer. From August 2015 to June 2016, 10 patients treated with preoperative CRT followed by surgery were enrolled. Patients received conventional fractionated radiotherapy (50.4 Gy) with fluorouracil-based chemotherapy. Surgical resection was performed at 4 to 8 weeks after the completion of preoperative CRT. The absolute blood lymphocyte subpopulation was obtained prior to and after 4 weeks of CRT. We analyzed the association between a tumor response and change in the lymphocyte subpopulation during CRT. Among 10 patients, 2 (20%) had evidence of pathologic complete response. In 8 patients with clinically node positive, 4 (50%) had nodal tumor response. All lymphocyte subpopulation counts at 4 weeks after CRT were significantly lower than those observed during pretreatment (p < 0.01). A high decrease in natural killer (NK) cell, count during CRT (baseline cell count - cell count at 4 weeks) was associated with node down staging (p = 0.034). Our results suggest that the change of lymphocyte subset to preoperative CRT may be a predictive factor for tumor response in rectal cancer.

  18. Blood count in new onset atrial fibrillation after acute myocardial infarction - A hypothesis generating study

    Directory of Open Access Journals (Sweden)

    Klaus Distelmaier

    2014-01-01

    Interpretation & conclusions: This study shows a significant independent association between serum haemoglobin, haematocrit, erythrocyte count and occurrence of AF after AMI. However, the pathophysiologic mechanism underlying these associations and its potential clinical applicability need to be further elucidated.

  19. Interactions between cadmium and decabrominated diphenyl ether on blood cells count in rats-Multiple factorial regression analysis.

    Science.gov (United States)

    Curcic, Marijana; Buha, Aleksandra; Stankovic, Sanja; Milovanovic, Vesna; Bulat, Zorica; Đukić-Ćosić, Danijela; Antonijević, Evica; Vučinić, Slavica; Matović, Vesna; Antonijevic, Biljana

    2017-02-01

    The objective of this study was to assess toxicity of Cd and BDE-209 mixture on haematological parameters in subacutely exposed rats and to determine the presence and type of interactions between these two chemicals using multiple factorial regression analysis. Furthermore, for the assessment of interaction type, an isobologram based methodology was applied and compared with multiple factorial regression analysis. Chemicals were given by oral gavage to the male Wistar rats weighing 200-240g for 28days. Animals were divided in 16 groups (8/group): control vehiculum group, three groups of rats were treated with 2.5, 7.5 or 15mg Cd/kg/day. These doses were chosen on the bases of literature data and reflect relatively high Cd environmental exposure, three groups of rats were treated with 1000, 2000 or 4000mg BDE-209/kg/bw/day, doses proved to induce toxic effects in rats. Furthermore, nine groups of animals were treated with different mixtures of Cd and BDE-209 containing doses of Cd and BDE-209 stated above. Blood samples were taken at the end of experiment and red blood cells, white blood cells and platelets counts were determined. For interaction assessment multiple factorial regression analysis and fitted isobologram approach were used. In this study, we focused on multiple factorial regression analysis as a method for interaction assessment. We also investigated the interactions between Cd and BDE-209 by the derived model for the description of the obtained fitted isobologram curves. Current study indicated that co-exposure to Cd and BDE-209 can result in significant decrease in RBC count, increase in WBC count and decrease in PLT count, when compared with controls. Multiple factorial regression analysis used for the assessment of interactions type between Cd and BDE-209 indicated synergism for the effect on RBC count and no interactions i.e. additivity for the effects on WBC and PLT counts. On the other hand, isobologram based approach showed slight antagonism

  20. Interactions between cadmium and decabrominated diphenyl ether on blood cells count in rats—Multiple factorial regression analysis

    International Nuclear Information System (INIS)

    Curcic, Marijana; Buha, Aleksandra; Stankovic, Sanja; Milovanovic, Vesna; Bulat, Zorica; Đukić-Ćosić, Danijela; Antonijević, Evica; Vučinić, Slavica; Matović, Vesna; Antonijevic, Biljana

    2017-01-01

    The objective of this study was to assess toxicity of Cd and BDE-209 mixture on haematological parameters in subacutely exposed rats and to determine the presence and type of interactions between these two chemicals using multiple factorial regression analysis. Furthermore, for the assessment of interaction type, an isobologram based methodology was applied and compared with multiple factorial regression analysis. Chemicals were given by oral gavage to the male Wistar rats weighing 200–240 g for 28 days. Animals were divided in 16 groups (8/group): control vehiculum group, three groups of rats were treated with 2.5, 7.5 or 15 mg Cd/kg/day. These doses were chosen on the bases of literature data and reflect relatively high Cd environmental exposure, three groups of rats were treated with 1000, 2000 or 4000 mg BDE-209/kg/bw/day, doses proved to induce toxic effects in rats. Furthermore, nine groups of animals were treated with different mixtures of Cd and BDE-209 containing doses of Cd and BDE-209 stated above. Blood samples were taken at the end of experiment and red blood cells, white blood cells and platelets counts were determined. For interaction assessment multiple factorial regression analysis and fitted isobologram approach were used. In this study, we focused on multiple factorial regression analysis as a method for interaction assessment. We also investigated the interactions between Cd and BDE-209 by the derived model for the description of the obtained fitted isobologram curves. Current study indicated that co-exposure to Cd and BDE-209 can result in significant decrease in RBC count, increase in WBC count and decrease in PLT count, when compared with controls. Multiple factorial regression analysis used for the assessment of interactions type between Cd and BDE-209 indicated synergism for the effect on RBC count and no interactions i.e. additivity for the effects on WBC and PLT counts. On the other hand, isobologram based approach showed slight

  1. Effect of a 21-day balneotherapy program on blood cell counts, ponogen levels, and blood biochemical indexes in servicemen in sub-health condition.

    Science.gov (United States)

    Xu, Li; Wu, Lin; Liu, Tingting; Xing, Wenrong; Cao, Xinsheng; Zhang, Shu; Su, Zongyi

    2017-09-01

    [Purpose] The aim of our study was to explore the changes in the blood of servicemen in sub-health conditions during a 21-day balneotherapy program. [Subjects and Methods] For this study, 129 servicemen in sub-health condition were recruited. The subjects were randomly divided into either the balneotherapy group (70) or the control group (59). Subjects in the balneotherapy group received whole-body immersion bath therapy in thermomineral water (30 min daily) for 21 days. Their blood samples were examined 1 day before and after balneotherapy. The parameters studied included mean corpuscular hemoglobin (MCH), mean corpuscular hemoglobin concentration (MCHC), white blood cell (WBC), lactic acid (LAC), alanine aminotransferase (ALT), glucose (GLU), and triglycerides (TG) levels. [Results] After 21 days of balneotherapy, MCH levels and MCHC increased significantly and WBC counts increased significantly. LAC levels decreased significantly. ALT, GLU, and TG levels decreased significantly. In the control group, there were no statistical differences before and after tap water baths following the same procedure. [Conclusion] A 21-day balneotherapy program significantly improved blood cell counts and blood biochemical indexes and reduced ponogen levels in servicemen in sub-health condition.

  2. Accurate measurement of peripheral blood mononuclear cell concentration using image cytometry to eliminate RBC-induced counting error.

    Science.gov (United States)

    Chan, Leo Li-Ying; Laverty, Daniel J; Smith, Tim; Nejad, Parham; Hei, Hillary; Gandhi, Roopali; Kuksin, Dmitry; Qiu, Jean

    2013-02-28

    Peripheral blood mononuclear cells (PBMCs) have been widely researched in the fields of immunology, infectious disease, oncology, transplantation, hematological malignancy, and vaccine development. Specifically, in immunology research, PBMCs have been utilized to monitor concentration, viability, proliferation, and cytokine production from immune cells, which are critical for both clinical trials and biomedical research. The viability and concentration of isolated PBMCs are traditionally measured by manual counting with trypan blue (TB) using a hemacytometer. One of the common issues of PBMC isolation is red blood cell (RBC) contamination. The RBC contamination can be dependent on the donor sample and/or technical skill level of the operator. RBC contamination in a PBMC sample can introduce error to the measured concentration, which can pass down to future experimental assays performed on these cells. To resolve this issue, RBC lysing protocol can be used to eliminate potential error caused by RBC contamination. In the recent years, a rapid fluorescence-based image cytometry system has been utilized for bright-field and fluorescence imaging analysis of cellular characteristics (Nexcelom Bioscience LLC, Lawrence, MA). The Cellometer image cytometry system has demonstrated the capability of automated concentration and viability detection in disposable counting chambers of unpurified mouse splenocytes and PBMCs stained with acridine orange (AO) and propidium iodide (PI) under fluorescence detection. In this work, we demonstrate the ability of Cellometer image cytometry system to accurately measure PBMC concentration, despite RBC contamination, by comparison of five different total PBMC counting methods: (1) manual counting of trypan blue-stained PBMCs in hemacytometer, (2) manual counting of PBMCs in bright-field images, (3) manual counting of acetic acid lysing of RBCs with TB-stained PBMCs, (4) automated counting of acetic acid lysing of RBCs with PI-stained PBMCs

  3. White blood cell and platelet count as adjuncts to standard clinical evaluation for risk assessment in patients at low probability of acute aortic syndrome.

    Science.gov (United States)

    Morello, Fulvio; Cavalot, Giulia; Giachino, Francesca; Tizzani, Maria; Nazerian, Peiman; Carbone, Federica; Pivetta, Emanuele; Mengozzi, Giulio; Moiraghi, Corrado; Lupia, Enrico

    2017-08-01

    Pre-test probability assessment is key in the approach to suspected acute aortic syndromes (AASs). However, most patients with AAS-compatible symptoms are classified at low probability, warranting further evaluation for decision on aortic imaging. White blood cell count, platelet count and fibrinogen explore pathophysiological pathways mobilized in AASs and are routinely assayed in the workup of AASs. However, the diagnostic performance of these variables for AASs, alone and as a bundle, is unknown. We tested the hypothesis that white blood cell count, platelet count and/or fibrinogen at presentation may be applied as additional tools to standard clinical evaluation for pre-test risk assessment in patients at low probability of AAS. This was a retrospective observational study conducted on consecutive patients managed in our Emergency Department from 2009 to 2014 for suspected AAS. White blood cell count, platelet count and fibrinogen were assayed during evaluation in the Emergency Department. The final diagnosis was obtained by computed tomography angiography. The pre-test probability of AAS was defined according to guidelines. Of 1210 patients with suspected AAS, 1006 (83.1%) were classified at low probability, and 271 (22.4%) were diagnosed with AAS. Within patients at low probability, presence of at least one alteration among white blood cell count >9*10 3 /µl, platelet count probability, white blood cell count >9*10 3 /µl and platelet count probability, the estimated risk of AAS based on the number of alterations amongst white blood cell count >9*10 3 /µl and platelet count probability to fine-tune risk assessment of AAS.

  4. IMPACT OF 10 SESSIONS OF WHOLE BODY CRYOSTIMULATION ON AEROBIC AND ANAEROBIC CAPACITY AND ON SELECTED BLOOD COUNT PARAMETERS

    Directory of Open Access Journals (Sweden)

    Tomasz Dybek

    2012-01-01

    Full Text Available The systemic effect of low temperature suggests that sessions in a cryogenic chamber might improve athletes’ capacity as a standard element of training. Therefore the authors decided to evaluate the impact of 10 sessions of whole body cryostimulation (WBCT on aerobic and anaerobic efficiency as well as on selected blood count parameters. The study group included 32 volunteers – 16 women and 16 men. The volunteers underwent 10 sessions of WBCT in a cryogenic chamber. Blood samples (RBC, WBC, PLT, HGB, HCT were taken, and aerobic and anaerobic efficiency and lactate concentration in capillary blood were measured before the first session and one day after the last one. No significant differences were observed in values of aerobic capacity after 10 sessions of WBCT. There was a rising trend in men and a declining trend in women. The lactate concentration did not differ significantly before and after WBCT. A slight rise in aerobic and anaerobic threshold was observed in men, while in women the values slightly fell. The Wingate test showed no significant differences in results before and after cryostimulation. Only the TOBT was significantly shorter in men (6.12±1.49 vs 3.79±1.14 s. The WBCT sessions resulted in a significant rise of the haematological parameters both in women and men, excluding HCT, which showed a statistically insignificant rise. Ten sessions of whole body cryostimulation did not affect aerobic or anaerobic capacity in the tested group, although it improved the blood count parameters.

  5. Decline of blood leukocyte counts 1947-59, Hiroshima and Nagasaki

    Energy Technology Data Exchange (ETDEWEB)

    Ichimaru, Michito; Ueda, Shoichi; Blaisdell, R K

    1963-03-03

    Earlier reports of progressive decline in leukocyte counts in Hiroshima from about 1948 to 1954 have been confirmed. A similar phenomenon has been observed in Nagasaki. Analysis indicates that this decline in white cell count with time is not related to exposure to the 1945 atomic bombs, to sex, to age, to commonly diagnosed diseases, or to the disproportionate influence of a subgroup. The principal white cells affected were neutrophils, lymphocytes and eosinophils. The precise etiologic factors accounting for the decline, and the biological significance of the present lower range of leukocyte values in Hiroshima and Nagasaki remain to be determined. 16 references, 5 figures, 5 tables.

  6. Branched-chain amino acid-enriched nutrient increases blood platelet count in patients after endoscopic injection sclerotherapy.

    Science.gov (United States)

    Furuichi, Yoshihiro; Imai, Yasuharu; Miyata, Yuki; Sugimoto, Katsutoshi; Sano, Takatomo; Taira, Junichi; Kojima, Mayumi; Kobayashi, Yoshiyuki; Nakamura, Ikuo; Moriyasu, Fuminori

    2016-10-01

    Protein and energy malnutrition is a severe problem for patients with liver cirrhosis (LC) and fasting often induces starvation which is a vitally important outcome. Dietary restriction is essential for endoscopic injection sclerotherapy (EIS) in patients with risky esophageal varices, thereby creating the possible exacerbation of nutritional state and inducing liver dysfunction. Whether EIS induces nutritional deficiency in LC patients and the effects of branched-chain amino acid (BCAA)-enriched nutrient are prospectively investigated. A total of 61 LC patients were randomly divided into an EIS monotherapy group (non-BCAA group, n = 31) and an EIS combined with BCAA therapy group (n = 30). Platelet count, blood chemistry and somatometry values were prospectively measured at five time points. The platelet counts before treatment were at the same level in both groups (P = 0.72). Three months after treatment, the counts decreased in the non-BCAA group; however, they increased in the BCAA group (P = 0.019). Body mass index, triceps skin fold thickness and arm muscle circumference significantly decreased in both groups. The BCAA and tyrosine ratio value increased only in the BCAA group (P BCAA group (P BCAA. Administration of BCAA had some effect in maintaining the nutritional state, and may improve the platelet count. Taking a greater amount of nutrients and shorter dietary restriction period or hospitalization was desirable. © 2016 The Japan Society of Hepatology.

  7. Evaluation of ICT filariasis card test using whole capillary blood: comparison with Knott's concentration and counting chamber methods.

    Science.gov (United States)

    Njenga, S M; Wamae, C N

    2001-10-01

    An immunochromatographic card test (ICT) that uses fingerprick whole blood instead of serum for diagnosis of bancroftian filariasis has recently been developed. The card test was validated in the field in Kenya by comparing its sensitivity to the combined sensitivity of Knott's concentration and counting chamber methods. A total of 102 (14.6%) and 117 (16.7%) persons was found to be microfilaremic by Knott's concentration and counting chamber methods, respectively. The geometric mean intensities (GMI) were 74.6 microfilariae (mf)/ml and 256.5 mf/ml by Knott's concentration and counting chamber methods, respectively. All infected individuals detected by both Knott's concentration and counting chamber methods were also antigen positive by the ICT filariasis card test (100% sensitivity). Further, of 97 parasitologically amicrofilaremic persons, 24 (24.7%) were antigen positive by the ICT. The overall prevalence of antigenemia was 37.3%. Of 100 nonendemic area control persons, none was found to be filarial antigen positive (100% specificity). The results show that the new version of the ICT filariasis card test is a simple, sensitive, specific, and rapid test that is convenient in field settings.

  8. Further investigations on the influence of ultraviolet irradiation on blood corpuscles hemoglobin content and differential leucocyte count in the chicken

    International Nuclear Information System (INIS)

    Bolukbasi, F.

    1978-01-01

    The influence of ultraviolet irradiation, applied for one hour, with a relatively high enerqy output of 95.5x10 3 erg. cm -2 . sn -1 , on some biological parameters of chicken's blood was determined. At the 24th hour after irradiation erythrocyte count, hemoglobin content and percentages of lymphocytes, monocytes, eosinophils and basophils were decreased, but total leucocyte, thrombocyte counts and percentage of pseudoeosinophils were increased, significantly (P< 0,01). No significant changes were obtained in all parameters, at the 24th hour after a second irradiation. There were also found no differences between the values obtained at 24th hour after the second, and at 48th hour after the single irradiation, but all these values had a tendency taward the initial determinations

  9. Association of the blood eosinophil count with hematological malignancies and mortality

    DEFF Research Database (Denmark)

    Andersen, Christen Bertel L; Siersma, Volkert Dirk; Hasselbalch, Hans K

    2015-01-01

    Blood eosinophilia (≥0.5 × 109/l) may be an early sign of hematological malignancy. We investigated associations between levels of blood eosinophils and risks of hematological malignancies and mortality in order to provide clinically derived cut-offs for referral to specialist hematology care. Fr...

  10. Studies on the chronological alterations of blood counts on the radiological technicians at health centers in Japan (1957 - 1975)

    International Nuclear Information System (INIS)

    Endo, Kouichi; Ishizaka, Masatsuna

    1977-01-01

    From the nine health surveys made on clinical radiation technicians working at health centers during the 18 years from 1957 to 1975, 679 technicians on whom blood examinations were made for not less than ten consecutive years were sampled to investigate for chronological alterations in their blood parameters. The radiation protective means at the health centers have made rapid progress ever since the atomic bomb experiment in 1954, and the dose of exposure to radiation then began to decrease. On the other hand, it was in about 1960 that the measurement of individual exposure doses began to be made on 60% of all the technicians. Chronological alterations in the average blood counts of these technicians under the abovementioned situation were such that RBC and hemoglobin level continued to increase from 1963 until about 1967, but then began to decrease, and that WBC was as low as 5,883/mm 3 in 1957, but tended to increase though slightly at each of the subsequent surveys, and was increased to 6,570/mm 3 in 1975, that is, WBC has been approaching the normal count of 6,774/mm 3 in the Japanese, with a significant difference at a not more than 1% level of significance in each survey year. For the purpose of preventing radiation hazard, further efforts should be made to protect the technicians from exposure to radiation and to control their health. (auth.)

  11. Smart fast blood counting of trace volumes of body fluids from various mammalian species using a compact custom-built microscope cytometer (Conference Presentation)

    Science.gov (United States)

    Smith, Zachary J.; Gao, Tingjuan; Lin, Tzu-Yin; Carrade-Holt, Danielle; Lane, Stephen M.; Matthews, Dennis L.; Dwyre, Denis M.; Wachsmann-Hogiu, Sebastian

    2016-03-01

    Cell counting in human body fluids such as blood, urine, and CSF is a critical step in the diagnostic process for many diseases. Current automated methods for cell counting are based on flow cytometry systems. However, these automated methods are bulky, costly, require significant user expertise, and are not well suited to counting cells in fluids other than blood. Therefore, their use is limited to large central laboratories that process enough volume of blood to recoup the significant capital investment these instruments require. We present in this talk a combination of a (1) low-cost microscope system, (2) simple sample preparation method, and (3) fully automated analysis designed for providing cell counts in blood and body fluids. We show results on both humans and companion and farm animals, showing that accurate red cell, white cell, and platelet counts, as well as hemoglobin concentration, can be accurately obtained in blood, as well as a 3-part white cell differential in human samples. We can also accurately count red and white cells in body fluids with a limit of detection ~3 orders of magnitude smaller than current automated instruments. This method uses less than 1 microliter of blood, and less than 5 microliters of body fluids to make its measurements, making it highly compatible with finger-stick style collections, as well as appropriate for small animals such as laboratory mice where larger volume blood collections are dangerous to the animal's health.

  12. Early intraoperative blood collection does not affect complete blood counts, von Willebrand factor or factor VIII levels in normal children.

    Science.gov (United States)

    Darwish, Hanni; Mundell, Gillianne; Engen, Dale; Lillicrap, David; Silva, Mariana; James, Paula

    2011-01-01

    Obtaining blood from children for research studies can be difficult, particularly for controls. One solution is to obtain samples during elective surgery; however, consideration must be given to the potential effects of the timing of phlebotomy. Ten children were recruited and phlebotomy was carried out during a preoperative clinic visit and intraoperatively immediately after the induction of anesthesia but before the start of surgery. CBCs, VWF, and FVIII levels were measured at both time points and no significant differences were seen. This negative result may be beneficial to pediatric research by suggesting that early intraoperative blood collection for controls does not affect the results.

  13. Evaluation of correlation between nucleated red blood cell count in term newborns and meconium-stained amniotic fluid

    Directory of Open Access Journals (Sweden)

    Esmaeilian L

    2001-09-01

    Full Text Available Considering the incidence of meconium-stained amniotic fluid (MSAF in newborns and its complications, and also based on indirect reports pointing out relationship between nucleated red blood cell (nRBC, as a marker of chronic hypoxia, and MSAF in term newborns, and in order to determine this relationship more accurately, this study was done on women with uncomplicated singleton term pregnancy that admitted for delivery at Shariati hospital in year 2000. After excluding confounding factors on nRBC, case group who includes infants with MSAF, and control group who have clear amniotic fluid were determined. Maternal age and parity, gestational age, birth weight, apgar score, neonatal out come, and FHR pattern as well as newborn hemoglobin values were evaluated. Venous cord blood was analyzed for nRBC counts per 100 WBC. Case and control groups were divided according to nRBC counts with cutoff point of 10 and then compared statistically. From the samples, 117 cases and 67 controls were evaluated. Maternal and neonatal factors were similar in two situations. Number of nRBC was 3.75±4.8 in control group and 12.04±11.7 in case group (P<0.01 and it was abnormal (>10 in 9 percent of newborns with clear fluid and 32 percent of MSAF (P<0.01. Cord blood nRBC count increased when meconium is passed intrauterine. This suggests that cases with MSAF may be at risk of chronic hypoxia. Cohort research is recommended to study the affect of delivery mode on the neonatal outcome in cases with MSAF and to evaluate the cause of fetal hypoxia in uncomplicated pregnancy with MSAF.

  14. On Orbit Immuno-Based, Label-Free, White Blood Cell Counting System with MicroElectroMechanical Sensor (MEMS) Technology (OILWBCS-MEMS), Phase II

    Data.gov (United States)

    National Aeronautics and Space Administration — Aurora Flight Sciences Corporation and partner, Draper Laboratory, propose to develop an on-orbit immuno-based label-free white blood cell counting system using MEMS...

  15. White blood cell counts and neutrophil to lymphocyte ratio in the diagnosis of testicular cancer: a simple secondary serum tumor marker.

    Science.gov (United States)

    Yuksel, Ozgur Haki; Verit, Ayhan; Sahin, Aytac; Urkmez, Ahmet; Uruc, Fatih

    2016-01-01

    The aim of the study was to investigate white blood cell counts and neutrophil to lymphocyte ratio (NLR) as markers of systemic inflammation in the diagnosis of localized testicular cancer as a malignancy with initially low volume. Thirty-six patients with localized testicular cancer with a mean age of 34.22±14.89 years and 36 healthy controls with a mean age of 26.67±2.89 years were enrolled in the study. White blood cell counts and NLR were calculated from complete blood cell counts. White blood cell counts and NLR were statistically significantly higher in patients with testicular cancer compared with the control group (ptesticular cancer besides the well-known accurate serum tumor markers as AFP (alpha fetoprotein), hCG (human chorionic gonadotropin) and LDH (lactate dehydrogenase).

  16. On Orbit Immuno-Based, Label-Free, White Blood Cell Counting System with MicroElectroMechanical Sensor (MEMS) Technology (OILWBCS-MEMS), Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — Aurora Flight Sciences Corporation and our partner, Draper Laboratory, propose to develop an on orbit immuno-based, label-free, white blood cell counting system for...

  17. Effect of indomethacin, diclofenac sodium and sodium salicylate on peripheral blood cell counts in sublethally gamma-irradiated mice

    International Nuclear Information System (INIS)

    Pospisil, M.; Netikova, J.; Kozubik, A.; Pipalova, I.

    1989-01-01

    Treatment with indomethacin and diclofenac sodium was found to increase granulocyte counts in the blood of sublethally gamma-irradiated mice. Treatment with sodium salicylate was ineffective in this respect, administration of sodium salicylate together with indomethacin even decreased the indomethacin-induced effects. The results suggest that the hemopoiesis-stimulating effects of non-steroidal anti-flammatory drugs cannot be correlated with the anti-inflammatory activity but rather with the side effects of these compounds, including the action on gastro-intestinal prostanoid production. This conclusion doubts on the possibility of the usefulness of non-steroidal anti-inflammatory drugs in conditions of the radiation syndrome. (orig.) [de

  18. Absolute counts of peripheral blood leukocyte subpopulations in intraabdominal sepsis and pneumonia-derived sepsis: a pilot study Absolute counts of peripheral blood leukocyte subpopulations in intraabdominal sepsis and pneumonia-derived sepsis: a pilot study

    Directory of Open Access Journals (Sweden)

    Grazyna Anna Hoser

    2012-10-01

    Full Text Available The leading pathophysiological changes during sepsis include systemic abnormalities in the immune
    response. Due to the general character of these disturbances, sepsis is usually studied as a homogenous clinical
    condition. We aimed to compare the immune response in intraabdominal sepsis (IAS and pneumonia-derived
    sepsis (PDS. The following cell populations were examined: white blood cell count (WBC, monocytes, lymphocytes:
    CD3+, CD4+ and CD8+ T cells, B cells, and NK cells. In both studied groups (i.e. IAS and PDS, the
    WBC was elevated. However, it was significantly higher in the IAS group than in the PDS group. The difference
    was due to a lower granulocyte count, as well as a lower monocyte count in PDS. We found no significant
    correlation between the total lymphocyte number and CD3+CD8+ T cells in either form of sepsis. Similarly, we
    observed no correlation between the total lymphocyte number and the NK cells subset in IAS. However, the
    numbers of CD3+CD8+ and NK cells correlated similarly in both types of sepsis. Both studied types of sepsis
    induced profound lymphocytopenia, with marked loss of CD8+ T cells and the NK cells. However, the similar
    relation between them, which was independent of the infection type, suggests that the NK and CD3+CD8+ cells
    have shared mechanisms of regulation. The primary site of infection has an impact on the global immune reaction.
    These alternations include especially myeloid cells: granulocytes and monocytes which disappear from peripheral
    blood during PDS, but increase in IAS.
    The leading pathophysiological changes during sepsis include systemic abnormalities in the immune
    response. Due to the general character of these disturbances, sepsis is usually studied as a homogenous clinical
    condition. We aimed to compare the immune response in intraabdominal sepsis (IAS and pneumonia-derived
    sepsis (PDS. The following cell

  19. Usefulness of estimation of blood procalcitonin concentration versus C-reactive protein concentration and white blood cell count for therapeutic monitoring of sepsis in neonates

    Directory of Open Access Journals (Sweden)

    Agnieszka Kordek

    2014-12-01

    Full Text Available Aim: This study was intended to assess the clinical usefulness of blood procalcitonin (PCT concentrations for the diagnosis and therapeutic monitoring of nosocomial neonatal sepsis.Material/Methods: The enrolment criterion was sepsis clinically manifesting after three days of life. PCT concentrations were measured in venous blood from 52 infected and 88 uninfected neonates. The results were interpreted against C-reactive protein (CRP concentrations and white blood cell counts (WBC.Results: Differences between the two groups in PCT and CRP concentrations were highly significant. No significant differences between the groups were noted for WBC. The threshold value on the receiver operator characteristic curve was 2.06 ng/mL for PCT (SE 75%; SP 80.68%; PPV 62.22%; NPV 88.75%; AUC 0.805, 5.0 mg/L for CRP (SE 67.44%; SP 73.68%; PPV 42.02%; NPV 88.89%; AUC 0.801, and 11.9 x109/L for WBC (SE 51.16%; SP 50.68%; PPV 23.16%; NPV 78.13%; AUC 0.484. Procalcitonin concentrations decreased 24 hours after initiation of antibiotic therapy and reverted to the control level after 5-7 days. C-reactive protein concentrations began to decline after two days of antibiotic therapy but were still higher than in the control group after 5-7 days of treatment. No significant changes in WBC during the treatment were observed.Conclusions: Procalcitonin concentrations in blood appear to be of use for the diagnosis and therapeutic monitoring of nosocomial infections in neonates as this parameter demonstrates greater sensitivity and specificity than C-reactive protein. White blood cell counts appear to be of little diagnostic value in the early phase of infection or for therapeutic monitoring.

  20. Pre-therapeutic blood dosimetry in patients with differentiated thyroid carcinoma using 124-iodine. Predicted blood doses correlate with changes in blood cell counts after radioiodine therapy and depend on modes of TSH stimulation and number of preceding radioiodine therapies

    International Nuclear Information System (INIS)

    Hartung-Knemeyer, V.; Nagarajah, J.; Jentzen, W.; Ruhlmann, M.; Freudenberg, L.S.; Stahl, A.R.; Bockisch, A.; Rosenbaum-Krumme, S.J.

    2012-01-01

    Pre-therapeutic blood dosimetry prior to a high-dose radioiodine therapy (RAIT) is recommended and a blood dose of 2 Gy is considered to be safe. In this study, changes in the blood cell count after radioiodine therapy of high risk differentiated thyroid carcinoma (DTC) were analyzed and compared with the results of the pre-therapeutic blood dosimetry using 124 I. Moreover, the influence of different modes of TSH stimulation and the number of preceding radioiodine therapies on the blood dose were assessed. 198 patients with locally advanced or metastasized DTC received a pre-therapeutic blood dosimetry using 124 I. To analyze the influence of the modes of TSH stimulation and the number of preceding RAITs on blood dose subgroups were built as follows: patients with endogenous TSH stimulation versus patients with exogenous TSH stimulation and patients with no preceding RAIT versus patients with at least one preceding RAIT. In 124/198 patients subsequent RAIT was performed. In 73/124 patients, hemograms were performed from day 2 to 12 month after RAIT. There was no high-grade bone marrow toxicity (id est (i.e.) ≥grade 3) in patients receiving less than 2 Gy blood dose-independent of the therapeutic history. Within the first month after radioiodine therapy, there was an overall decrease in the white blood cell and platelet counts. The erythrocyte count was essentially stable. There was a correlation between cell count decrease and predicted blood doses (Spearman's correlation coefficient >-0.6 each) for the white cell line and the platelets. With regard to the subgroups, the blood dose per administered 131 I activity (BDpA) was significantly higher in patients with endogenous TSH stimulation (median 0.08 Gy/GBq) than in patients with exogenous TSH stimulation (0.06 Gy/GBq) and in patients with no previous RAIT (0.08 Gy/GBq) compared to patients who had previously undergone at least one RAIT (0.07 Gy/GBq). The range of BDpA among DTC patients is rather wide. Our

  1. Peripheral blood count in preoperative radiotherapy (with radiomodificators) of lung cancer

    International Nuclear Information System (INIS)

    Demidchik, Yu.E.; Zharkov, V.V.; Prokhorova, V.I.; Rubanova, C.Z.

    1989-01-01

    Indices of peripheral blood in 215 patients with lung cancer during preoperative radiation using hyperglycemia or metronidazole are studied. It is shown that after preoperative radiotherapy, when radiomodifying effects are not used, the content of erythrocytes, thrombocytes, leukocytes, the concentration of hemoglobin in peripheral blood, as well as erythrocyte sedimentation rare didn't change. Functional disorders of the leukopoietic function and the thrombopoietic function of bone marrow when using metronidazole are registered when applying various types of preoperative radiotherapy. Lymphopenia is established when using various types of radiotherapy with radiomodificators

  2. Differential associations between white blood cell counts and fatigue in young and older adults

    DEFF Research Database (Denmark)

    Avlund, Kirsten; Hokland, Marianne; Mehlsen, Mimi Yung

    2012-01-01

    The aims of this exploratory study were to study whether fatigue might be related to the cellular immune system by 1) analysing if the number of white blood cell subsets are related to fatigue and 2) if possible relationships vary in younger and older community-dwelling individuals....

  3. Four-Parameter white blood cell differential counting based on light scattering measurements

    NARCIS (Netherlands)

    Terstappen, Leonardus Wendelinus Mathias Marie; de Grooth, B.G.; Visscher, K.; Kouterik, F.A.; Greve, Jan

    1988-01-01

    Measurement of the depolarized orthogonal light scattering in flow cytometry enables one to discriminate human eosinephilic granulocytes from neutrophilic granulocytes. We use this method to perform a four-parameter differential white blood cell analysis. A simple flow cytometer was built equipped

  4. Sample to answer visualization pipeline for low-cost point-of-care blood cell counting

    CSIR Research Space (South Africa)

    Smith, S

    2015-02-01

    Full Text Available and flow rates, and 2) a microscopy analysis system to investigate homogeneity and concentration of blood cells. Fluidic parameters were derived from the optical flow as well as color-based segmentation of the different fluids using a hue...

  5. The Influence of Low Platelet Count on Whole Blood Aggregometry Assessed by Multiplate

    DEFF Research Database (Denmark)

    Stissing, Trine; Dridi, Nadia P; Ostrowski, Sisse R

    2011-01-01

    in an artificial matrix, platelet-rich plasma (PRP). Heparinized and citrated blood was diluted with autologous plasma to platelet concentrations 200 to 25 × 10(9)/L in WB samples (n = 10) and 200 to 100 × 10(9)/L in PRP samples (n = 7). The platelet aggregation was investigated by the ADP-, ASPI-, COL-, and TRAP...

  6. [Full blood count reference values in children of 8 to 12 years old residing at 2,760 m above sea level].

    Science.gov (United States)

    Armando García-Miranda, L; Contreras, I; Estrada, J A

    2014-04-01

    To determine reference values for full blood count parameters in a population of children 8 to 12 years old, living at an altitude of 2760 m above sea level. Our sample consisted of 102 individuals on whom a full blood count was performed. The parameters included: total number of red blood cells, platelets, white cells, and a differential count (millions/μl and %) of neutrophils, lymphocytes, monocytes, eosinophils and basophils. Additionally, we obtained values for hemoglobin, hematocrit, mean corpuscular volume, mean corpuscular hemoglobin, concentration of corpuscular hemoglobin and red blood cell distribution width. The results were statistically analyzed with a non-parametric test, to divide the sample in quartiles and obtain the lower and upper limits for our intervals. Moreover, the values for the intervals obtained from this analysis were compared to intervals obtained estimating+- 2 standard deviations above and below from our mean values. Our results showed significant differences compared to normal interval values reported for the adult Mexican population in most of the parameters studied. The full blood count is an important laboratory test used routinely for the initial assessment of a patient. Values of full blood counts in healthy individuals vary according to gender, age and geographic location; therefore, each population should have its own reference values. Copyright © 2013 Asociación Española de Pediatría. Published by Elsevier Espana. All rights reserved.

  7. Fibrinogen, viscosity, and white blood cell count are major risk factors for ischemic heart disease. The Caerphilly and Speedwell collaborative heart disease studies.

    Science.gov (United States)

    Yarnell, J W; Baker, I A; Sweetnam, P M; Bainton, D; O'Brien, J R; Whitehead, P J; Elwood, P C

    1991-03-01

    Recent studies have suggested that hemostatic factors and white blood cell count are predictive of ischemic heart disease (IHD). The relations of fibrinogen, viscosity, and white blood cell count to the incidence of IHD in the Caerphilly and Speedwell prospective studies are described. The two studies have a common core protocol and are based on a combined cohort of 4,860 middle-aged men from the general population. The first follow-up was at a nearly constant interval of 5.1 years in Caerphilly and 3.2 years in Speedwell; 251 major IHD events had occurred. Age-adjusted relative odds of IHD for men in the top 20% of the distribution compared with the bottom 20% were 4.1 (95% confidence interval, 2.6-6.5) for fibrinogen, 4.5 (95% confidence interval, 2.8-7.4) for viscosity, and 3.2 (95% confidence interval, 2.0-4.9) for white blood cell count. Associations with IHD were similar in men who had never smoked, exsmokers, and current smokers, and the results suggest that at least part of the effect of smoking on IHD is mediated through fibrinogen, viscosity, and white blood cell count. Multivariate analysis shows that white blood cell count is an independent risk factor for IHD as is either fibrinogen or viscosity, or possibly both. Jointly, these three variables significantly improve the fit of a logistic regression model containing all the main conventional risk factors. Further, a model including age, smoking habits, fibrinogen, viscosity, and white blood cell count predicts IHD as well as one in which the three hemostatic/rheological variables are replaced by total cholesterol, diastolic pressure, and body mass index. Jointly, fibrinogen, viscosity, and white blood cell count are important risk factors for IHD.

  8. The Influence of Low Platelet Count on Whole Blood Aggregometry Assessed by Multiplate

    DEFF Research Database (Denmark)

    Stissing, Trine; Dridi, Nadia P; Ostrowski, Sisse R

    2011-01-01

    in an artificial matrix, platelet-rich plasma (PRP). Heparinized and citrated blood was diluted with autologous plasma to platelet concentrations 200 to 25 × 10(9)/L in WB samples (n = 10) and 200 to 100 × 10(9)/L in PRP samples (n = 7). The platelet aggregation was investigated by the ADP-, ASPI-, COL-, and TRAP......-test. The WB responses decreased at platelet concentration of ≤100 × 10(9)/L (all P PRP samples at platelet concentrations 200 to 100 × 10(9)/L (P

  9. Full blood count and haemozoin-containing leukocytes in children with malaria: diagnostic value and association with disease severity

    Directory of Open Access Journals (Sweden)

    Lell Bertrand

    2008-06-01

    Full Text Available Abstract Background Diligent and correct laboratory diagnosis and up-front identification of risk factors for progression to severe disease are the basis for optimal management of malaria. Methods Febrile children presenting to the Medical Research Unit at the Albert Schweitzer Hospital (HAS in Lambaréné, Gabon, were assessed for malaria. Giemsa-stained thick films for qualitative and quantitative diagnosis and enumeration of malaria pigment, or haemozoin (Hz-containing leukocytes (PCL were performed, and full blood counts (FBC were generated with a Cell Dyn 3000® instrument. Results Compared to standard light microscopy of Giemsa-stained thick films, diagnosis by platelet count only, by malaria pigment-containing monocytes (PCM only, or by pigment-containing granulocytes (PCN only yielded sensitivities/specificities of 92%/93%; 96%/96%; and 85%/96%, respectively. The platelet count was significantly lower in children with malaria compared to those without (p ® instrument detected significantly more patients with PCL (p Conclusion In the age group examined in the Lambaréné area, platelets are an excellent adjuvant tool to diagnose malaria. Pigment-containing leukocytes (PCL are more readily detected by automated scatter flow cytometry than by microscopy. Automated Hz detection by an instrument as used here is a reliable diagnostic tool and correlates with disease severity. However, clinical usefulness as a prognostic tool is limited due to an overlap of PCL numbers recorded in severe versus non-severe malaria. However, this is possibly because of the instrument detection algorithm was not geared towards this task, and data lost during processing; and thus adjusting the instrument's algorithm may allow to establish a meaningful cut-off value.

  10. Comparison of the peripheral blood eosinophil count using near-patient testing and standard automated laboratory measurement in healthy, asthmatic and COPD subjects

    Directory of Open Access Journals (Sweden)

    Hambleton K

    2017-09-01

    Full Text Available Kirsty Hambleton, Clare M Connolly, Catherine Borg, Joanne H Davies, Helen P Jeffers, Richard EK Russell, Mona Bafadhel Respiratory Medicine Unit, Nuffield Department of Clinical Medicine, University of Oxford, Oxford, UK Abstract: Near-patient testing (NPT allows clinical decisions to be made in a rapid and convenient manner and is often cost effective. In COPD the peripheral blood eosinophil count has been demonstrated to have utility in providing prognostic information and predicting response to treatment during an acute exacerbation. For this potential to be achieved having a reliable NPT of blood eosinophil count would be extremely useful. Therefore, we investigated the use of the HemoCue® WBC Diff System and evaluated its sensitivity and specificity in healthy, asthmatic and COPD subjects. This method requires a simple skin prick of blood and was compared to standard venepuncture laboratory analysis. The HemoCue® WBC Diff System measured the peripheral blood eosinophil count in healthy, asthma and COPD subjects with very close correlation to the eosinophil count as measured by standard venepuncture. The correlations were unaffected by disease status. This method for the measurement of the peripheral blood eosinophil count has the potential to provide rapid near-patient results and thus influence the speed of management decisions in the treatment of airway diseases. Keywords: asthma, chronic obstructive pulmonary disease, eosinophils, near-patient testing

  11. Effect of prewarming EDTA blood samples to 37°C on platelet count measured by Sysmex XT-2000iV in dogs, cats, and horses.

    Science.gov (United States)

    Williams, Tim L; Archer, Joy

    2016-09-01

    Pseudothrombocytopenia secondary to platelet clumping is a common cause of preanalytic error for platelet counts in dogs, cats, and horses. In human beings, it is suggested that prewarming blood samples to 37°C prior to hematology analysis will reduce platelet clumping. The purpose of the study was to evaluate the effect of prewarming EDTA blood samples to 37°C on measured platelet counts and other hematologic variables. The EDTA blood samples from dogs, cats and horses submitted to the clinical pathology laboratory at the University of Cambridge were included. Complete blood cell counts performed using a Sysmex XT-2000iV hematology analyzer were done on samples at room temperature (approximately 22°C) and following warming of the samples to 37°C in a water bath. The Wilcoxon signed rank test was used to compare hematologic variables, including platelet count, before and after sample warming to 37°C. Data are presented as median (25(th) , 75(th) percentile) increase. Blood samples from 39 dogs, 19 cats, and 10 horses were included. Sample warming to 37°C resulted in a statistically significant increase in platelet counts in dogs (11 [-2, 30] ×10(9) /L), cats (36 [14, 84] ×10(9) /L), and horses (42 [31, 79] ×10(9) /L). Sample warming did not significantly affect other hematologic variables. Prewarming EDTA blood samples to 37°C prior to hematologic analysis increased platelet counts overall in canine, feline, and equine blood, but did not abrogate platelet clumping and pseudothrombocytopenia fully in some cases. Furthermore, true pseudothrombocytopenia was not confirmed in these animals. © 2016 American Society for Veterinary Clinical Pathology.

  12. Variation in blood serum proteins and association with somatic cell count in dairy cattle from multi-breed herds.

    Science.gov (United States)

    Bobbo, T; Fiore, E; Gianesella, M; Morgante, M; Gallo, L; Ruegg, P L; Bittante, G; Cecchinato, A

    2017-12-01

    Blood serum proteins are significant indicators of animal health. Nevertheless, several factors should be considered to appropriately interpret their concentrations in blood. Therefore, the objectives of this study were (1) to assess the effect of herd productivity, breed, age and stage of lactation on serum proteins and (2) to investigate association between serum proteins and somatic cell count (SCC) in dairy cattle. Milk and blood samples were collected from 1508 cows of six different breeds (Holstein Friesian, Brown Swiss, Jersey, Simmental, Rendena and Alpine Grey) that were housed in 41 multi-breed herds. Milk samples were analyzed for composition and SCC, while blood samples were analyzed for serum proteins (i.e. total protein, albumin, globulin and albumin-to-globulin ratio (A : G)). Herds were classified as low or high production, according to the cow's average daily milk energy yield adjusted for breed, days in milk (DIM) and parity. Data were analyzed using a linear mixed model that included the fixed effects of DIM, parity, SCS, breed, herd productivity and the random effect of the Herd-test date within productivity level. Cows in high producing herds (characterized also by greater use of concentrates in the diet) had greater serum albumin concentrations. Breed differences were reported for all traits, highlighting a possible genetic mechanism. The specialized breed Jersey and the two dual-purpose local breeds (Alpine Grey and Rendena) had the lowest globulin concentration and greatest A : G. Changes in serum proteins were observed through lactation. Total protein reached the highest concentration during the 4th month of lactation. Blood albumin increased with DIM following a quadratic pattern, while globulin decreased linearly. As a consequence, A : G increased linearly during lactation. Older cows had greater total protein and globulin concentrations, while albumin concentration seemed to be not particularly affected by age. A linear relationship

  13. A simple method for regional cerebral blood flow measurement by one-point arterial blood sampling and 123I-IMP microsphere model (part 2). A study of time correction of one-point blood sample count

    International Nuclear Information System (INIS)

    Masuda, Yasuhiko; Makino, Kenichi; Gotoh, Satoshi

    1999-01-01

    In our previous paper regarding determination of the regional cerebral blood flow (rCBF) using the 123 I-IMP microsphere model, we reported that the accuracy of determination of the integrated value of the input function from one-point arterial blood sampling can be increased by performing correction using the 5 min: 29 min ratio for the whole-brain count. However, failure to carry out the arterial blood collection at exactly 5 minutes after 123 I-IMP injection causes errors with this method, and there is thus a time limitation. We have now revised out method so that the one-point arterial blood sampling can be performed at any time during the interval between 5 minutes and 20 minutes after 123 I-IMP injection, with addition of a correction step for the sampling time. This revised method permits more accurate estimation of the integral of the input functions. This method was then applied to 174 experimental subjects: one-point blood samples collected at random times between 5 and 20 minutes, and the estimated values for the continuous arterial octanol extraction count (COC) were determined. The mean error rate between the COC and the actual measured continuous arterial octanol extraction count (OC) was 3.6%, and the standard deviation was 12.7%. Accordingly, in 70% of the cases, the rCBF was able to be estimated within an error rate of 13%, while estimation was possible in 95% of the cases within an error rate of 25%. This improved method is a simple technique for determination of the rCBF by 123 I-IMP microsphere model and one-point arterial blood sampling which no longer shows a time limitation and does not require any octanol extraction step. (author)

  14. Evaluation of the performance of a point-of-care method for total and differential white blood cell count in clozapine users.

    Science.gov (United States)

    Bui, H N; Bogers, J P A M; Cohen, D; Njo, T; Herruer, M H

    2016-12-01

    We evaluated the performance of the HemoCue WBC DIFF, a point-of-care device for total and differential white cell count, primarily to test its suitability for the mandatory white blood cell monitoring in clozapine use. Leukocyte count and 5-part differentiation was performed by the point-of-care device and by routine laboratory method in venous EDTA-blood samples from 20 clozapine users, 20 neutropenic patients, and 20 healthy volunteers. From the volunteers, also a capillary sample was drawn. Intra-assay reproducibility and drop-to-drop variation were tested. The correlation between both methods in venous samples was r > 0.95 for leukocyte, neutrophil, and lymphocyte counts. The correlation between point-of-care (capillary sample) and routine (venous sample) methods for these cells was 0.772; 0.817 and 0.798, respectively. Only for leukocyte and neutrophil counts, the intra-assay reproducibility was sufficient. The point-of-care device can be used to screen for leukocyte and neutrophil counts. Because of the relatively high measurement uncertainty and poor correlation with venous samples, we recommend to repeat the measurement with a venous sample if cell counts are in the lower reference range. In case of clozapine therapy, neutropenia can probably be excluded if high neutrophil counts are found and patients can continue their therapy. © 2016 John Wiley & Sons Ltd.

  15. [Changes and significance of peripheral blood platelet count in tumor shrinkage induced by a low dose of CTX in T739 mice].

    Science.gov (United States)

    Li, Mo-lin; Jia, Yu-jie; Jiang, Miao-na; Shu, Xiao-hong; Li, Chuan-gang

    2008-06-01

    To establish a mouse model for BTT739 tumor-bearing mice cured by a low dose of cyclophosphamide (CTX). And then to observe the dynamic changes and significance of peripheral blood counts especially blood platelet count during tumor shrinkage induced by a low dose of CTX in T739 mice. Mouse bladder carcinoma tissues were inoculated subcutaneously into T739 mice. Seven days later, different doses of CTX or the same volume of NS were administered intraperitoneally to treat these tumor-bearing T739 mice. Tumor sizes were observed and recorded subsequently to find out the minimal dose of CTX that could cure most of these tumor-bearing mice. Then another 12 tumor-bearing mice were randomly divided into 15 mg/kg CTX treatment group and control group. Blood samples were obtained from orbital venous sinus on different times after CTX treatment. Complete blood counts were performed and the relationship between peripheral blood platelet counts and tumor shrinkage was analyzed. Within 2 weeks after CTX treatment, the speed of tumor shrinkage had a positive relationship with the dose of CTX used; but the survival rate of the tumor-bearing mice had a negative relationship with the dose of CTX used in 2 months after CTX treatment. 15 mg/kg CTX could cure most of the tumor bearing mice, while it had no remarkably inhibitive effects on peripheral blood cells. The perpherial platelet count increased to (1483.4+/-184.4)x10(9)/L in mice 6 h after CTX treatment. There was significant difference compared with that in mice of control group (1086.6+/-81.0)x10(9)/L (P0.05). CTX 15 mg/kg could cure most of bladder tumor-bearing T739 mice. The transient increase of the peripheral platelet count in 6 h after CTX treatment may relate to the antitumor effects of CTX.

  16. Blood Culture (For Parents)

    Science.gov (United States)

    ... Metabolic Panel (BMP) Blood Test: Complete Blood Count Basic Blood Chemistry Tests Getting a Blood Test (Video) Blood Test: Basic Metabolic Panel Blood Test: Comprehensive Metabolic Panel Blood ...

  17. A retrospective analysis of the impact of treatments and blood counts on survival and the risk of vascular events during the course of polycythaemia vera

    DEFF Research Database (Denmark)

    Enblom-Larsson, Anneli; Girodon, Francois; Bak, Marie

    2017-01-01

    Vascular and non-vascular complications are common in patients with polycythaemia vera. This retrospective study of 217 patients with polycythaemia vera aimed to determine whether blood counts with respect to different treatments influenced the complication rate and survival. We found that 78 (36...

  18. Effects of Wine by-Products on Growth Performance, Complete Blood Count and Total Antioxidant Status in Broilers

    Directory of Open Access Journals (Sweden)

    SM Pascariu

    Full Text Available ABSTRACT This study aimed to investigate the effect of whole grape pomace (GP, grape seed (GS and grape pomace polyphenolic extract (GPEP on growth performance, total antioxidant status (TAS and complete blood count (CBC of 40-day-old chicks (hybrid Cobb 500. A total of 432 unsexed one-day-old chicks were divided into six groups: control (CON and five experimental groups, 10 g/kg GP, 20 g/kg GP, 5 g/kg GS, 10 g/kg GS and 15 mL/L GPEP. The results showed a higher increase in growing rate in 5 g/kg GS group, from the first week of the chicks’ life throughout their growth, the average body weight of the chicks being significantly higher (p0.05 at 40 days of age. As a conclusion, the amount of 5 g/kg seeds, 10 g/kg and 20 g/kg pomace, can be added to the diet of the broilers, the dose of 5 g/kg seeds in the diet offering advantages in growing rate and feed valorization in weight gain.

  19. Protective effect of curcumin on experimentally induced arthritic rats: detailed histopathological study of the joints and white blood cell count

    Science.gov (United States)

    Kamarudin, Taty Anna; Othman, Faizah; Mohd Ramli, Elvy Suhana; Md Isa, Nurismah; Das, Srijit

    2012-01-01

    Curcuma longa (turmeric) rhizomes contains curcumin, an active compound which possesses anti-inflammatory effects. Collagen-induced arthritis (CIA) is an accepted experimental animal model of rheumatoid arthritis. The present study aimed to observe the histological changes in the joints of experimental arthritic rats treated with curcumin. Twenty four male Sprague-Dawley (approximately 7 weeks-old) rats were randomly divided into four groups. Three groups were immunized with 150 µg collagen. All rats with established CIA, with arthritis scores exceeding 1, were orally treated with betamethasone (0.5 mg/ml/kg body weight), curcumin (110 mg/ml/kg body weight) or olive oil (1.0 ml/kg body weight) daily, for two weeks. One remaining group was kept as normal control. Treatment with 110 mg/ml/kg curcumin showed significant mean differences in the average white blood cell (WBC) count (pPannus formation scores showed that curcumin supplementation successfully suppressed the pannus formation process that occurred in the articular cartilage of the CIA joints. The mean difference for histological scores for the curcumin group was insignificant compared to the betamethasone treated group. It is concluded that supplementation of curcumin has protective effect on the histopathological and degenerative changes in the joints of CIA rats which was at par with betamethasone. PMID:27366139

  20. Protective effect of curcumin on experimentally induced arthritic rats: detailed histopathological study of the joints and white blood cell count.

    Science.gov (United States)

    Kamarudin, Taty Anna; Othman, Faizah; Mohd Ramli, Elvy Suhana; Md Isa, Nurismah; Das, Srijit

    2012-01-01

    Curcuma longa (turmeric) rhizomes contains curcumin, an active compound which possesses anti-inflammatory effects. Collagen-induced arthritis (CIA) is an accepted experimental animal model of rheumatoid arthritis. The present study aimed to observe the histological changes in the joints of experimental arthritic rats treated with curcumin. Twenty four male Sprague-Dawley (approximately 7 weeks-old) rats were randomly divided into four groups. Three groups were immunized with 150 µg collagen. All rats with established CIA, with arthritis scores exceeding 1, were orally treated with betamethasone (0.5 mg/ml/kg body weight), curcumin (110 mg/ml/kg body weight) or olive oil (1.0 ml/kg body weight) daily, for two weeks. One remaining group was kept as normal control. Treatment with 110 mg/ml/kg curcumin showed significant mean differences in the average white blood cell (WBC) count (pcurcumin supplementation successfully suppressed the pannus formation process that occurred in the articular cartilage of the CIA joints. The mean difference for histological scores for the curcumin group was insignificant compared to the betamethasone treated group. It is concluded that supplementation of curcumin has protective effect on the histopathological and degenerative changes in the joints of CIA rats which was at par with betamethasone.

  1. Understanding Blood Counts

    Science.gov (United States)

    ... Certain drugs Infection Chemotherapy and other medicines Malaria Alcoholism AIDS Lupus Enlarged spleen Pregnancy Idiopathic thrombocytopenic purpura Thrombotic thrombocytopenic purpura Hemolytic uremic ...

  2. White Blood Cell Count

    Science.gov (United States)

    ... Pp 1003-1008. Harmening D. Clinical Hematology and Fundamentals of Hemostasis, Fifth Edition, F.A. Davis Company, Philadelphia, 2009, Pp 305-328. Henry's Clinical Diagnosis and Management by Laboratory Methods. 21st ed. McPherson R, Pincus ...

  3. Complete blood count - slideshow

    Science.gov (United States)

    ... Duplication for commercial use must be authorized in writing by ADAM Health Solutions. About MedlinePlus Site Map FAQs Customer Support Get email updates Subscribe to RSS Follow us Disclaimers Copyright ...

  4. The calorically restricted low-fat nutrient-dense diet in Biosphere 2 significantly lowers blood glucose, total leukocyte count, cholesterol, and blood pressure in humans.

    Science.gov (United States)

    Walford, R L; Harris, S B; Gunion, M W

    1992-12-01

    Biosphere 2 is a 3.15-acre space containing an ecosystem that is energetically open (sunlight, electric power, and heat) but materially closed, with air, water, and organic material being recycled. Since September 1991, eight subjects (four women and four men) have been sealed inside, living on food crops grown within. Their diet, low in calories (average, 1780 kcal/day; 1 kcal = 4.184 kJ), low in fat (10% of calories), and nutrient-dense, conforms to that which in numerous animal experiments has promoted health, retarded aging, and extended maximum life span. We report here medical data on the eight subjects, comparing preclosure data with data through 6 months of closure. Significant changes included: (i) weight, 74 to 62 kg (men) and 61 to 54 kg (women); (ii) mean systolic/diastolic blood pressure (eight subjects), 109/74 to 89/58 mmHg (1 mmHg = 133 Pa); (iii) total serum cholesterol, from 191 +/- 11 to 123 +/- 9 mg/dl (mean +/- SD; 36% mean reduction), and high density lipoprotein, from 62 +/- 8 to 38 +/- 5 (risk ratio unchanged); (iv) triglyceride, 139 to 96 mg/dl (men) and 78 to 114 mg/dl (women); (v) fasting glucose, 92 to 74 mg/dl; (vi) leukocyte count, 6.7 to 4.7 x 10(9) cells per liter. We conclude that drastic reductions in cholesterol and blood pressure may be instituted in normal individuals in Western countries by application of a carefully chosen diet and that a low-calorie nutrient-dense regime shows physiologic features in humans similar to those in other animal species.

  5. CELL RESPIRATION STUDIES : II. A COMPARATIVE STUDY OF THE OXYGEN CONSUMPTION OF BLOOD FROM NORMAL INDIVIDUALS AND PATIENTS WITH INCREASED LEUCOCYTE COUNTS (SEPSIS; CHRONIC MYELOGENOUS LEUCEMIA).

    Science.gov (United States)

    Daland, G A; Isaacs, R

    1927-06-30

    1. The oxygen consumption of blood of normal individuals, when the hemoglobin is saturated with oxygen, is practically zero within the limits of experimental error of the microspirometer used. 2. The oxygen consumed in a microspirometer by the blood of patients with chronic myelogenous leucemia with a high white blood cell count, and of one with leucocytosis from sepsis, was proportional to the number of adult polymorphonuclear neutrophils in the blood. 3. No correlation could be made between the rate of oxygen absorption and the total number of white blood cells in the blood, or the total number of immature cells, or the number of red blood cells, or the amount of oxyhemoglobin. 4. The blood of patients with chronic myelogenous leucemia continued to use oxygen in the microspirometer longer than that of normal individuals, and the hemoglobin, in the leucemic bloods, became desaturated even though exposed to air. 5. In blood in which the bulk. of the cells were immature and the mature cells few, the oxygen consumption was lower than in blood in which the mature cells predominated. The rate of oxygen consumption of the immature cells was relatively low as compared to the mature. 6. The slower rate of oxygen absorption by the immature leucocytes in chronic myelogenous leucemia as compared to the mature cells, places them, in accord with Warburg's reports, in the class of the malignant tissues in this respect rather than in the group of young or embryonic cells.

  6. Sex based levels of C-reactive protein and white blood cell count in subjects with metabolic syndrome: Isfahan Healthy Heart Program.

    Science.gov (United States)

    Gharipour, Mojgan; Ramezani, Mohammad Arash; Sadeghi, Masuomeh; Khosravi, Alireza; Masjedi, Mohsen; Khosravi-Boroujeni, Hossein; Rafieian-Kopaei, Mahmoud; Sarrafzadegan, Nizal

    2013-06-01

    C-reactive protein (CRP) and white blood cell (WBC) are proinflammatory markers. They are major pathophysiological for the development of metabolic syndrome (MetS). This study aimed to address the independent associations between MetS and WBC counts and serum CRP levels and evaluation of their magnitude in relation to the MetS, based on the sex in the Iranian adults. In this cross-sectional study, subjects who met the MetS criteria, based on the Adult Treatment Panel III were selected from the Isfahan Healthy Heart Program database. A questionnaire containing the demographic data, weight, height, waist, and hip circumference of the respondents was completed for each person. Blood pressure was measured and the anthropometric measurements were done, and fasting blood samples were taken for 2 h postload plasma glucose (2 hpp). Serum [total, high-density lipoprotein (HDL), and low-density lipoprotein] levels of cholesterol, triglyceride, and CRP as well as WBC counts were determined. The univariate analyses were carried out to assess the relation between the CRP levels, WBC counts with the MetS in both sexes the. In men with the abdominal obesity, the higher levels of WBC count, high serum triglyceride and blood glucose levels, a low serum HDL level, and raised systolic and diastolic blood pressure were observed. However, the higher serum CRP levels were only observed in those with the low serum HDL-cholesterol levels. The mean values of the WBC counts were statistically different between the men with and without MetS, but the mean values of the CRP levels were similar between the two groups. In women, the mean values of WBC count and CRP levels were statistically different in the subjects with and without a MetS components (except for the low serum HDL levels and high diastolic blood pressure for the WBC measures and abdominal obesity for the CRP measures) and for those with and without MetS. The age and smoking adjusted changes in the CRP levels and WBC counts

  7. Effect of Tree Leaves on Rumen Fermentation, Microbial Count and Blood Urea Nitrogen of West African Dwarf Goats

    Directory of Open Access Journals (Sweden)

    Adelusi, O. O.

    2016-12-01

    Full Text Available This experiment was carried out to assess the effect of Azadirachta indica, Newbouldia laevis and Spondias mombin leaves on rumen fermentation, microbial count and blood urea nitrogen (BUN of West African Dwarf (WAD goats. Sixteen WAD bucks (11.6 ? 0.9 kg in body weight were allocated to 4 treatments: 1 Control and 2 40 g/day of Azadirachta indica, 3 40 g/day of Newbouldia laevis and 4 40 g/day of Spondias mombin leaves arranged in a completely randomised design. The ground leaves were included in concentrate diets served on dry matter basis at 2% of body weight while Panicum maximum was fed ad libitum. The control diet had no tree leaves. Data were collected on chemical composition, rumen fermentation and microbial ecology, and BUN. Saponin was highest (P < 0.05 in S. mombin (8.14% while A. indica and N. laevis had 5.78% and 1.56%, respectively. Rumen ammonia nitrogen was least (P < 0.05 in goats fed A. indica (8.35 mg/dL while the highest (P < 0.05 total volatile fatty acid (TVFA was obtained from goats fed S. mombin with 125.51 mM. Goats fed N. laevis yielded the highest (P < 0.05 acetate with 70.65 mol/100 mol while propionate production was highest (P < 0.05 in the rumen of goats fed S. mombin (27.15 mol/100 mol. Viable bacteria count was lowest (P < 0.05 in rumen of goats fed A. indica (3.95?1012 cfu/ml while the least (P < 0.05 protozoa population was obtained from the rumen of bucks fed S. mombin (4.18?109 cfu/ml. All goats in the treatments containing tree leaves had higher (P < 0.05 and a rapid increase in BUN between 0 and 6 h post feeding when compared with the Control. It is concluded that feeding ground leaves of S. mombin to goats increases rumen total volatile fatty acid and propionate production and reduces the protozoa population.

  8. Cell type specific DNA methylation in cord blood: A 450K-reference data set and cell count-based validation of estimated cell type composition.

    Science.gov (United States)

    Gervin, Kristina; Page, Christian Magnus; Aass, Hans Christian D; Jansen, Michelle A; Fjeldstad, Heidi Elisabeth; Andreassen, Bettina Kulle; Duijts, Liesbeth; van Meurs, Joyce B; van Zelm, Menno C; Jaddoe, Vincent W; Nordeng, Hedvig; Knudsen, Gunn Peggy; Magnus, Per; Nystad, Wenche; Staff, Anne Cathrine; Felix, Janine F; Lyle, Robert

    2016-09-01

    Epigenome-wide association studies of prenatal exposure to different environmental factors are becoming increasingly common. These studies are usually performed in umbilical cord blood. Since blood comprises multiple cell types with specific DNA methylation patterns, confounding caused by cellular heterogeneity is a major concern. This can be adjusted for using reference data consisting of DNA methylation signatures in cell types isolated from blood. However, the most commonly used reference data set is based on blood samples from adult males and is not representative of the cell type composition in neonatal cord blood. The aim of this study was to generate a reference data set from cord blood to enable correct adjustment of the cell type composition in samples collected at birth. The purity of the isolated cell types was very high for all samples (>97.1%), and clustering analyses showed distinct grouping of the cell types according to hematopoietic lineage. We explored whether this cord blood and the adult peripheral blood reference data sets impact the estimation of cell type composition in cord blood samples from an independent birth cohort (MoBa, n = 1092). This revealed significant differences for all cell types. Importantly, comparison of the cell type estimates against matched cell counts both in the cord blood reference samples (n = 11) and in another independent birth cohort (Generation R, n = 195), demonstrated moderate to high correlation of the data. This is the first cord blood reference data set with a comprehensive examination of the downstream application of the data through validation of estimated cell types against matched cell counts.

  9. Keto analogues and amino acids supplementation induces a decrease of white blood cell counts and a reduction of muscle damage during intense exercise under thermoneutral conditions.

    Science.gov (United States)

    Lima, R C P; Camerino, S R A S; França, T C L; Rodrigues, D S A; Gouveia, M G S; Ximenes-da-Silva, A; Bassini, A; Prado, E S; Cameron, L C

    2017-04-19

    This study evaluated the acute effect of keto analogue and amino acid (AA-KAAA) supplementation on both white blood cell counts and the established biomarkers of muscle damage during exercise under thermoneutral conditions. Sixteen male cyclists received a ketogenic diet for two days and were divided into two equal groups: a group taking AA-KAAA (KA) or a control group (PL). The athletes performed a two hour cycling session followed by a maximum incremental test until voluntary exhaustion (VExh). Blood samples were obtained at rest and during exercise for further hematological and biochemical analyses. Exercise-induced ammonemia increased in the PL group at VExh (75%) but remained unchanged in the KA group. Both groups exhibited a significant increase in leukocyte and neutrophil counts of ∼85% (∼13 × 10 9 L -1 ), but the shape of the lymphocytes and the eosinophil counts suggest that AA-KAAA supplementation helps prevent lymphocytosis. AA-KAAA supplementation induced a decrease in creatine kinase and aspartate aminotransferase levels at VExh while showing a significant decrease in lactate dehydrogenase at 120 min. We found that AA-KAAA supplementation decreases both the lymphocyte count response in blood and the established biomarkers of muscle damage after intense exercise under a low heat stress environment.

  10. Effect of the addition of the antioxidant taurine on the complete blood count of whole blood stored at room temperature and at 4ºC for up to 7 days

    Directory of Open Access Journals (Sweden)

    Mahmoud Mohammed Sirdah

    2013-01-01

    Full Text Available BACKGROUND: The complete blood count is one of the most common routine tests. This study aimed to evaluate possible effects of the antioxidant taurine on the complete blood count of whole blood stored at room temperature and at 4ºC over seven days. METHODS: Venous blood samples of 25 healthy males were distributed into two sets of tubes with each set of four tubes containing 50 µL of solutions with zero, 2.5 g/L, 5 g/L, 10 g/L taurine. The tubes were kept at room temperature or at 4ºC. Complete blood counts were performed on seven successive days. The mean percentage changes [Δ = (mean value - mean baseline value / mean baseline value x 100] were calculated and compared. RESULTS: Complete blood count parameters exhibited different patterns of behavior which were affected by the storage temperature, time and taurine concentration. Taurine at room temperature significantly enhancedthe stability of: the platelet count over seven days (Δ7 at 2.5, 5 and 10 g/L taurine were 5.45, 6.11, and 5.80 x 10(9 cells/L, respectively; the red blood cell count over five days (Δ5 at 2.5, 5 and 10 g/L taurine were 1.59, 2.79, and 1.98 x 10(12 cells/L, respectively; mean corpuscular hemoglobin over five days (Δ5 at 2.5, 5 and 10 g/L taurine were -0.91,-1.52 and -0.84 fl respectively; and red cell distribution width over two days (Δ2 at 2.5, 5 and 10 g/L taurine were 0.90%, 1.30% and -0.1%, respectively. No additional stabilizing effects of taurine were reported for the mean corpuscular volume, mean corpuscular hemoglobin, mean corpuscular hemoglobin concentration, hematocrit and hemoglobin, while it negatively affected the white blood cell stability. CONCLUSION: Complete blood count parameters exhibited variable stability patterns in respect to temperature, time and taurine concentration.

  11. Relationship between high white blood cell count and insulin resistance (HOMA-IR) in Korean children and adolescents: Korean National Health and Nutrition Examination Survey 2008-2010.

    Science.gov (United States)

    Park, J-M; Lee, D-C; Lee, Y-J

    2017-05-01

    Increasing evidence has indicated that insulin resistance is associated with inflammation. However, few studies have investigated the association between white blood cell (WBC) count and insulin resistance, as measured by a homeostasis model assessment of insulin resistance (HOMA-IR) in a general pediatric population. This study aimed to examine the association between WBC count and insulin resistance as measured by HOMA-IR in a nationally representative sample of children and adolescents. In total, 2761 participants (1479 boys and 1282 girls) aged 10-18 years were selected from the 2008-2010 Korean National Health and Nutrition Examination Survey. Insulin resistance was defined as a HOMA-IR value greater than the 90th percentile. The odds ratios and 95% confidence intervals for insulin resistance were determined using multiple logistic regression analysis. The mean values of most cardiometabolic variables tended to increase proportionally with WBC count quartiles. The prevalence of insulin resistance significantly increased in accordance with WBC count quartiles in both boys and girls. Compared to individuals in the lowest WBC count quartile, the odds ratio for insulin resistance for individuals in the highest quartile was 2.84 in boys and 3.20 in girls, after adjusting for age, systolic blood pressure, body mass index, and waist circumference. A higher WBC count was positively associated with an increased risk of insulin resistance in Korean children and adolescents. This study suggests that WBC count could facilitate the identification of children and adolescents with insulin resistance. Copyright © 2017 The Italian Society of Diabetology, the Italian Society for the Study of Atherosclerosis, the Italian Society of Human Nutrition, and the Department of Clinical Medicine and Surgery, Federico II University. Published by Elsevier B.V. All rights reserved.

  12. Study on serum TNF-α level, B-cell count and T-cell subsets distribution in peripheral blood in patients with rheumatoid arthritis

    International Nuclear Information System (INIS)

    Shi Buqing

    2006-01-01

    Objective: To study the changes of serum TNF-α levels, B-cell count and T-cell subsets distribution in peripheral blood in patients with rheumatoid arthritis. Methods: Serum TNF-α levels (with RIA), B cell as well as T cell subsets distribution type (with monoclonal antibody technique) were examined in 37 patients with rheumatoid arthritis and 30 controls. Results Serum TNF-α levels and B lymphocytes count were significantly higher in the patients than those in controls (P 3 , CD 4 and CD 4 /CD 8 were obviously lower (P<0.01). Conclusion: Rheumatoid arthritis is an autoimmune disease with abnormal immunoregulation. (authors)

  13. Evaluation of left ventricular function in patients with atrial fibrillation by ECG gated blood pool scintigraphy. Using frame count normalization method

    Energy Technology Data Exchange (ETDEWEB)

    Akanabe, Hiroshi; Oshima, Motoo; Sakuma, Sadayuki

    1988-07-01

    The assumption necessary to perform ECG gated blood pool scintigraphy (EGBPS) are seemingly not valid for patients with atrial fibrillation (af), since they have wide variability in cardiac cycle length. The data were acquired in frame mode within the limits of mean heart rate of fix the first diastolic volume, and were calculated by frame count normalization (FCN) method to correct total counts in each frame. EGBPS were performed twelve patients with af, who were operated against valvular disease. The data acquired within mean heart rate +-10 % in frame mode were divided to 32 frames, and calculated total frame counts. With FCN method total frame counts from at 22nd to 32nd frame were multiplied to be equal to the average of total frame counts. FCN method could correct total frame counts at the latter frames. And there was good correlation between left ventricular ejection fraction calculated from scintigraphy and that from contrast cineangiography. Thus EGBPS with FCN method may be allow estimation of cardiac function even in subjects with af.

  14. Complete blood count risk score and its components, including RDW, are associated with mortality in the JUPITER trial.

    Science.gov (United States)

    Horne, Benjamin D; Anderson, Jeffrey L; Muhlestein, Joseph B; Ridker, Paul M; Paynter, Nina P

    2015-04-01

    Previously, we showed that sex-specific complete blood count (CBC) risk scores strongly predicted risk of all-cause mortality in multiple sets of general medical patients. This study evaluated the CBC risk score in an independent, well-studied international primary risk population of lower-risk individuals initially free from cardiovascular (CV) disease. Observational secondary analysis of a randomized trial population. The previously derived and validated CBC score was evaluated for association with all-cause mortality among CV disease-free females (n = 6568) and males (n = 10,629) enrolled for up to 5 years in the Justification for the Use of Statins in Prevention: an Intervention Trial Evaluating Rosuvastatin (JUPITER) trial. Associations of the CBC score with CV mortality and with major CV disease were also tested. The CBC score predicted all-cause mortality, with univariable hazard ratio (HR) 4.83 (95% CI 3.70-6.31) for the third CBC score tertile vs. the first tertile, and HR 2.31 (CI 1.75-3.05) for the second tertile (p trend JUPITER endpoint (p trend = 0.015). c-statistics for mortality were 0.729 among all, and 0.722 and 0.750 for females and males, respectively. The CBC risk score was strongly associated with all-cause mortality among JUPITER trial participants and had good discrimination. It also predicted CV-specific outcomes. This CBC score may be useful in identifying cardiac disease-free individuals at increased risk of mortality. © The European Society of Cardiology 2014 Reprints and permissions: sagepub.co.uk/journalsPermissions.nav.

  15. Maintenance therapy of childhood acute lymphoblastic leukemia revisited-Should drug doses be adjusted by white blood cell, neutrophil, or lymphocyte counts?

    Science.gov (United States)

    Schmiegelow, Kjeld; Nersting, Jacob; Nielsen, Stine Nygaard; Heyman, Mats; Wesenberg, Finn; Kristinsson, Jon; Vettenranta, Kim; Schrøeder, Henrik; Weinshilboum, Richard; Jensen, Katrine Lykke; Grell, Kathrine; Rosthoej, Susanne

    2016-12-01

    6-Mercaptopurine (6MP) and methotrexate (MTX) based maintenance therapy is a critical phase of childhood acute lymphoblastic leukemia treatment. Wide interindividual variations in drug disposition warrant frequent doses adjustments, but there is a lack of international consensus on dose adjustment guidelines. To identify relapse predictors, we collected 28,255 data sets on drug doses and blood counts (median: 47/patient) and analyzed erythrocyte (Ery) levels of cytotoxic 6MP/MTX metabolites in 9,182 blood samples (median: 14 samples/patient) from 532 children on MTX/6MP maintenance therapy targeted to a white blood cell count (WBC) of 1.5-3.5 × 10 9 /l. After a median follow-up of 13.8 years for patients in remission, stepwise Cox regression analysis did not find age, average doses of 6MP and MTX, hemoglobin, absolute lymphocyte counts, thrombocyte counts, or Ery levels of 6-thioguanine nucleotides or MTX (including its polyglutamates) to be significant relapse predictors. The parameters significantly associated with risk of relapse (N = 83) were male sex (hazard ratio [HR] 2.0 [1.3-3.1], P = 0.003), WBC at diagnosis (HR = 1.04 per 10 × 10 9 /l rise [1.00-1.09], P = 0.048), the absolute neutrophil count (ANC; HR = 1.7 per 10 9 /l rise [1.3-2.4], P = 0.0007), and Ery thiopurine methyltransferase activity (HR = 2.7 per IU/ml rise [1.1-6.7], P = 0.03). WBC was significantly related to ANC (Spearman correlation coefficient, r s  = 0.77; P best hematological target for dose adjustments of maintenance therapy. © 2016 Wiley Periodicals, Inc.

  16. High white blood cell count at diagnosis of childhood acute lymphoblastic leukaemia: biological background and prognostic impact. Results from the NOPHO ALL-92 and ALL-2000 studies

    DEFF Research Database (Denmark)

    Vaitkeviciene, G; Forestier, E; Hellebostad, M

    2011-01-01

    Prognostic impact of peripheral blood white blood cell count (WBC) at the diagnosis of childhood acute lymphoblastic leukaemia (ALL) was evaluated in a population-based consecutive series of 2666 children aged 1–15 treated for ALL between 1992 and 2008 in the five Nordic countries (Denmark, Finland.......58) and for T-ALL (pEFS5y 0.71 vs. 0.38). Whether the inferior EFS for the subset of patients with high WBC and slow initial response to treatment reflects rare or overlooked cytogenetic aberrations as well as the factors that determine WBC levels at diagnosis awaits exploration....

  17. Neutrophil to lymphocyte with monocyte to lymphocyte ratio and white blood cell count in prediction of lung cancer

    Directory of Open Access Journals (Sweden)

    Thang Thanh Phan

    2018-04-01

    Full Text Available Background Lung cancer is the most common cause of cancer deaths in both sexes, while it is very difficult for screenings and early detection. Aims This study aims to clarify the role of systematic inflammation markers, including white blood cell (WBC, neutrophil (NEU, monocyte (MONO, platelet (PLT, neutrophil to lymphocyte ratio (NLR, monocyte to lymphocyte ratio (MLR and platelet to lymphocyte ratio (PLR in prediction of lung cancer. Methods A case-control study was conducted on 1,315 primary lung cancer patients and 1,315 healthy adults with matched age and gender at Cho Ray hospital. NLR, MLR and PLR were calculated by using neutrophil, lymphocyte, monocyte and platelet count which were recalled from laboratory database. With 600 cases in the derivation set, the logistic regression with univariate analysis was used to identify the impacted marker, then developing the optimal prediction model for lung cancer by logistic regression with multivariate method. The diagnostic values of optimal model consisting of sensitivity (Sen, specificity (Spe, positive predictive value (PPV, negative predictive value (NPV and the area under the ROC curve (AUC value were extracted and verified on all data, in validation set. Results The median values of WBC, NEU, MONO, PLT, NLR, MLR and PLR in lung cancer were not significantly difference between histological subtypes and clinical stages (p > 0.05, but higher than the values in control group (p < 0.01. Multivariates analysis shows that NLR, MLR and WBC were three parameters that have the significant impact of the optimal prediction model (p < 0.01. The AUC value, sensitivity and specificity of the optimal model for lung cancer detection were 0.881, 73.5 per cent (95 per cent CI:70.3–76.6 and 87.7 per cent (95 per centCI:85.2–89.9, respectively. Whereas, the PPV and NPV values of prediction model were 85.7 per cent (95 per cent CI:82.8–88.2 and 76.8 (95 per centCI:73.9–79.5, respectively. Among three

  18. The role of donor characteristics and post-granulocyte colony-stimulating factor white blood cell counts in predicting the adverse events and yields of stem cell mobilization.

    Science.gov (United States)

    Chen, Shu-Huey; Yang, Shang-Hsien; Chu, Sung-Chao; Su, Yu-Chieh; Chang, Chu-Yu; Chiu, Ya-Wen; Kao, Ruey-Ho; Li, Dian-Kun; Yang, Kuo-Liang; Wang, Tso-Fu

    2011-05-01

    Granulocyte colony-stimulating factor (G-CSF) is now widely used for stem cell mobilization. We evaluated the role of post-G-CSF white blood cell (WBC) counts and donor factors in predicting adverse events and yields associated with mobilization. WBC counts were determined at baseline, after the third and the fifth dose of G-CSF in 476 healthy donors. Donors with WBC ≥ 50 × 10(3)/μL post the third dose of G-CSF experienced more fatigue, myalgia/arthralgia, and chills, but final post-G-CSF CD34(+) cell counts were similar. Although the final CD34(+) cell count was higher in donors with WBC ≥ 50 × 10(3)/μL post the fifth G-CSF, the incidence of side effects was similar. Females more frequently experienced headache, nausea/anorexia, vomiting, fever, and lower final CD34(+) cell count than did males. Donors with body mass index (BMI) ≥ 25 showed higher incidences of sweat and insomnia as well as higher final CD34(+) cell counts. Donor receiving G-CSF ≥ 10 μg/kg tended to experience bone pain, headache and chills more frequently. Multivariate analysis indicated that female gender is an independent factor predictive of the occurrence of most side effects, except for ECOG > 1 and chills. Higher BMI was also an independent predictor for fatigue, myalgia/arthralgia, and sweat. Higher G-CSF dose was associated with bone pain, while the WBC count post the third G-CSF was associated with fatigue only. In addition, one donor in the study period did not complete the mobilization due to suspected anaphylactoid reaction. Observation for 1 h after the first injection of G-CSF is required to prevent complications from unpredictable side effects.

  19. Amylase and blood cell-count hematological radiation-injury biomarkers in a rhesus monkey radiation model-use of multiparameter and integrated biological dosimetry

    Energy Technology Data Exchange (ETDEWEB)

    Blakely, W.F. [Uniformed Services University, Armed Forces Radiobiology Research Institute, 8901 Wisconsin Avenue, Bethesda, MD 20889-5603 (United States)], E-mail: blakely@afrri.usuhs.mil; Ossetrova, N.I.; Manglapus, G.L.; Salter, C.A.; Levine, I.H.; Jackson, W.E.; Grace, M.B.; Prasanna, P.G.S.; Sandgren, D.J.; Ledney, G.D. [Uniformed Services University, Armed Forces Radiobiology Research Institute, 8901 Wisconsin Avenue, Bethesda, MD 20889-5603 (United States)

    2007-07-15

    Effective medical management of suspected radiation exposure incidents requires the recording of dynamic medical data (clinical signs and symptoms), biological assessments of radiation exposure, and physical dosimetry in order to provide diagnostic information to the treating physician and dose assessment for personnel radiation protection records. The need to rapidly assess radiation dose in mass-casualty and population-monitoring scenarios prompted an evaluation of suitable biomarkers that can provide early diagnostic information after exposure. We investigated the utility of serum amylase and hematological blood-cell count biomarkers to provide early assessment of severe radiation exposures in a non-human primate model (i.e., rhesus macaques; n=8) exposed to whole-body radiation of {sup 60}Co-gamma rays (6.5 Gy, 40cGymin{sup -1}). Serum amylase activity was significantly elevated (12.3{+-}3.27- and 2.6{+-}0.058-fold of day zero samples) at 1 and 2-days, respectively, after radiation. Lymphocyte cell counts decreased ({<=}15% of day zero samples) 1 and 2 days after radiation exposure. Neutrophil cell counts increased at day one by 1.9({+-}0.38)-fold compared with levels before irradiation. The ratios of neutrophil to lymphocyte cell counts increased by 13({+-}2.66)- and 4.23({+-}0.95)-fold at 1 and 2 days, respectively, after irradiation. These results demonstrate that increases in serum amylase activity along with decreases of lymphocyte counts, increases in neutrophil cell counts, and increases in the ratio of neutrophil to lymphocyte counts 1 day after irradiation can provide enhanced early triage discrimination of individuals with severe radiation exposure and injury. Use of the biodosimetry assessment tool (BAT) application is encouraged to permit dynamic recording of medical data in the management of a suspected radiological casualty.

  20. Effect of supplements: Probiotics and probiotic plus honey on blood cell counts and serum IgA in patients receiving pelvic radiotherapy

    Directory of Open Access Journals (Sweden)

    Hajar-Alsadat Mansouri-Tehrani

    2015-01-01

    Full Text Available Background: Radiotherapy is frequently used in treatment approaches of pelvic malignancies. Nevertheless, it has some known systemic effects on blood cells and the immune system that possibly results in their susceptibility to infection. Probiotics are live microbial food ingredients that provide a health advantage to the consumer. Honey has prebiotic properties. The aim of this clinical trial was to investigate probable effects of probiotic or probiotics plus honey on blood cell counts and serum IgA levels in patients receiving pelvic radiotherapy. Materials and Methods: Sixty-seven adult patients with pelvic cancer were enrolled. Patients were randomized to receive either: (1 Probiotic capsules (including: Lactobacillus casei, Lactobacillus acidophilus, Lactobacillus rhamnosus, Lactobacillus bulgaricus, Bifidobacterium breve, Bifidobacterium longum, and Streptococcus thermophiles (n = 22, (2 probiotic capsules plus honey (n = 21 or (3 placebo capsules (n = 24 all for 6 weeks. Blood and serum samples were collected for one week before radiotherapy and 24-72 h after the end of radiotherapy. Results: White blood cells (WBC, red blood cells (RBC, platelet counts, and serum IgA level were not significantly changed in patients taking probiotic (alone or plus honey during pelvic radiotherapy. The mean decrease in RBC count was 0.52, 0.18, and 0.23 × 10 6 cells/μL, WBC count was 2.3, 1.21, and 1.34 × 10 3 cells/μL and platelet count was, 57.6, 53.3, and 66.35 × 10 3 cells/μL for the probiotic, probiotic plus honey, and placebo groups, respectively. The mean decrease of serum IgA was 22.53, 29.94, and 40.73 mg/dL for the probiotic, probiotic plus honey, and placebo groups, respectively. Conclusion: The observed nonsignificant effect of probiotics may be in favor of local effects of this product in the gut rather than systemic effects, however, as a trend toward a benefit was indicated, further studies are necessary in order to extract effects of

  1. Effect of supplements: Probiotics and probiotic plus honey on blood cell counts and serum IgA in patients receiving pelvic radiotherapy.

    Science.gov (United States)

    Mansouri-Tehrani, Hajar-Alsadat; Rabbani-Khorasgani, Mohammad; Hosseini, Sayyed Mohsen; Mokarian, Fariborz; Mahdavi, Hoda; Roayaei, Mahnaz

    2015-07-01

    Radiotherapy is frequently used in treatment approaches of pelvic malignancies. Nevertheless, it has some known systemic effects on blood cells and the immune system that possibly results in their susceptibility to infection. Probiotics are live microbial food ingredients that provide a health advantage to the consumer. Honey has prebiotic properties. The aim of this clinical trial was to investigate probable effects of probiotic or probiotics plus honey on blood cell counts and serum IgA levels in patients receiving pelvic radiotherapy. Sixty-seven adult patients with pelvic cancer were enrolled. Patients were randomized to receive either: (1) Probiotic capsules (including: Lactobacillus casei, Lactobacillus acidophilus, Lactobacillus rhamnosus, Lactobacillus bulgaricus, Bifidobacterium breve, Bifidobacterium longum, and Streptococcus thermophiles) (n = 22), (2) probiotic capsules plus honey (n = 21) or (3) placebo capsules (n = 24) all for 6 weeks. Blood and serum samples were collected for one week before radiotherapy and 24-72 h after the end of radiotherapy. White blood cells (WBC), red blood cells (RBC), platelet counts, and serum IgA level were not significantly changed in patients taking probiotic (alone or plus honey) during pelvic radiotherapy. The mean decrease in RBC count was 0.52, 0.18, and 0.23 × 10(6) cells/μL, WBC count was 2.3, 1.21, and 1.34 × 10(3) cells/μL and platelet count was, 57.6, 53.3, and 66.35 × 10(3) cells/μL for the probiotic, probiotic plus honey, and placebo groups, respectively. The mean decrease of serum IgA was 22.53, 29.94, and 40.73 mg/dL for the probiotic, probiotic plus honey, and placebo groups, respectively. The observed nonsignificant effect of probiotics may be in favor of local effects of this product in the gut rather than systemic effects, however, as a trend toward a benefit was indicated, further studies are necessary in order to extract effects of probiotics or probiotic plus honey on hematologic and

  2. Depression and anxiety symptoms are associated with white blood cell count and red cell distribution width: A sex-stratified analysis in a population-based study.

    Science.gov (United States)

    Shafiee, Mojtaba; Tayefi, Maryam; Hassanian, Seyed Mahdi; Ghaneifar, Zahra; Parizadeh, Mohammad Reza; Avan, Amir; Rahmani, Farzad; Khorasanchi, Zahra; Azarpajouh, Mahmoud Reza; Safarian, Hamideh; Moohebati, Mohsen; Heidari-Bakavoli, Alireza; Esmaeili, Habibolah; Nematy, Mohsen; Safarian, Mohammad; Ebrahimi, Mahmoud; Ferns, Gordon A; Mokhber, Naghmeh; Ghayour-Mobarhan, Majid

    2017-10-01

    Depression and anxiety are two common mood disorders that are both linked to systemic inflammation. Increased white blood cell (WBC) count and red cell distribution width (RDW) are associated with negative clinical outcomes in a wide variety of pathological conditions. WBC is a non-specific inflammatory marker and RDW is also strongly related to other inflammatory markers. Therefore, we proposed that there might be an association between these hematological inflammatory markers and depression/anxiety symptoms. The primary objective of this study was to examine the association between depression/anxiety symptoms and hematological inflammatory markers including WBC and RDW in a large population-based study. Symptoms of depression and anxiety and a complete blood count (CBC) were measured in 9274 participants (40% males and 60% females) aged 35-65 years, enrolled in a population-based cohort (MASHAD) study in north-eastern Iran. Symptoms of depression and anxiety were evaluated using the Beck Depression and Anxiety Inventories. The mean WBC count increased with increasing severity of symptoms of depression and anxiety among men. Male participants with severe depression had significantly higher values of RDW (panxiety symptoms had significantly higher values of RDW (panxiety. Our results suggest that higher depression and anxiety scores are associated with an enhanced inflammatory state, as assessed by higher hematological inflammatory markers including WBC and RDW, even after adjusting for potential confounders. Copyright © 2017 Elsevier Ltd. All rights reserved.

  3. 70-year old female patient with mismatch between hematocrit and hemoglobin values: the effects of cold agglutinin on complete blood count.

    Science.gov (United States)

    Ercan, Serif; Calışkan, Mustafa; Koptur, Erhan

    2014-01-01

    There are a number of pre-analytical and analytical factors, which cause false results in the complete blood count. The present case identifies cold agglutinins as the cause for the mismatch between hematocrit and hemoglobin values. 70-year old female patient had a history of cerebrovascular diseases and rheumatoid arthritis. During routine laboratory examination, the patient had normal leukocyte and platelet counts; however, the hemoglobin (Hb: 105 g/L) and hematocrit (HCT: 0.214 L/L) results were discordant. Hemolysis, lipemia and cold agglutinin were evaluated as possible reasons for the mismatch between hematocrit and hemoglobin values. First blood sample was slightly hemolysed. Redrawn sample without hemolysis or lipemia was analyzed but the mismatch became even more distinct (Hb: 104 g/L and HCT: 0.08 L/L). In this sample, the titration of the cold agglutinin was determined and found to be positive at 1:64 dilution ratios. After an incubation of the sample at 37°C for 2 hours, reversibility of agglutination was observed. We conclude that cold agglutinins may interfere with the analysis of erythrocyte and erythrocyte-related parameters (HCT, MCV, MCH and MCHC); however, Hb, leukocyte and platelet counts are not affected.

  4. Associations of White Blood Cell Count,Alanine Aminotransferase,and Aspartate Aminotransferase in the First Trimester withGestational Diabetes Mellitus.

    Science.gov (United States)

    Zhao, Li-li; Li, Wei; Ping, Fan; Ma, Liang-kun; Nie, Min

    2016-06-10

    Objective To explore the associations of white blood cell (WBC) count,alanine aminotransferase (ALT),and aspartate aminotransferase(AST) in the first trimester of pregnancy with gestational diabetes mellitus (GDM). Methods Totally 725 GDM women and 935 women who remained euglycemic throughout pregnancy were enrolled in this study. Pre-pregnancy weight/height were recorded. WBC,ALT,and AST levels were detected between 8 and 12 weeks of pregnancy.At 24 to 28 weeks of pregnancy,the glucose and insulin levels were measured. The WBC,ALT,and AST levels were compared between two groups,and the associations of WBC,ALT,and AST levels with the blood glucose and insulin levels were retrospectively analyzed. Meanwhile,the potential associations of those factors with the occurrence of GDM were analzyed. Results WBC count [9.41(8.15,10.84)?10(9)/L vs. 9.04 (7.64,10.37)?10(9)/L,P=1.0?10(-5)] and ALT levels [18.00(12.00,30.00)U/L vs. 16.00 (11.00,26.00)U/L,P=0.004] in the first trimester of pregnancy were significantly increased in GDM subjects than in normal glucose tolerance(NGT)subjects;however,the AST level showed no significant difference between these two groups [41.00 (26.00,43.00)U/L vs. 41.00 (23.00,43.00)U/L,P=0.588]. Logistic regression analysis illustrated that elevated WBC count was an independent risk factor for GDM after adjustment for age,pre-pregnancy body mass index,blood pressure,and family history of diabetes(OR=1.119,P=0.001). The ROC curve revealed that threshold of WBC count was 7.965?10(9)/L(AUC=0.566,P=1?10(-5)),which had a sensitivity of 79.4% and a specificity of 31.3%. Multivariate linear regression analysis showed that homeostasis model assessment of insulin resistance was positively correlated with WBC count(B=0.051,P=0.022,R(2)=0.083);1-hour blood glucose after oral 50 grams of sugar (B=0.044,P=0.001,R(2)=0.044) and fasting plasma true insulin(B=0.214,P=0.032,R(2)=0.066) were positively correlated with WBC count;1-hour true insulin after 100 grams

  5. Characteristics of Febrile Patients with Normal White Blood Cell Counts and High C-Reactive Protein Levels in an Emergency Department

    Directory of Open Access Journals (Sweden)

    Kuan-Ting Liu

    2008-05-01

    Full Text Available Fever is one of the more common chief complaints of patients who visit emergency departments (ED. Many febrile patients have markedly elevated C-reactive protein (CRP levels and normal white blood cell (WBC counts. Most of these patients have bacterial infection and no previous underlying disease of impaired WBC functioning. We reviewed patients who visited our ED between November 2003 and July 2004. The WBC count and CRP level of patients over 18 years of age who visited the ED because of or with fever were recorded. Patients who had normal WBC count (4,000–10,000/mL and high CRP level (> 100 mg/L were included. The data, including gender, age and length of hospital stay, were reviewed. Underlying diseases, diagnosis of the febrile disease and final condition were recorded according to the chart. Within the study period, 54,078 patients visited our ED. Of 5,628 febrile adults, 214 (3.8% had elevated CRP level and normal WBC count. The major cause of febrility was infection (82.24%. Most of these patients were admitted (92.99%. There were 32 patients with malignant neoplasm, nine with liver cirrhosis, 66 with diabetes mellitus and 11 with uremia. There were no significant differences in age and gender between patients with and those without neoplasm. However, a higher inhospital mortality rate and other causes of febrility were noted in patients with neoplasm. It was not rare in febrile patients who visited the ED to have a high CRP level but normal WBC count. These patients did not necessarily have an underlying malignant neoplasm or hematologic illness. Factors other than malignant neoplasm or hematologic illness may be associated with the WBC response, and CRP may be a better indicator of infection under such conditions.

  6. A rare IL33 loss-of-function mutation reduces blood eosinophil counts and protects from asthma

    DEFF Research Database (Denmark)

    Smith, Dirk; Helgason, Hannes; Sulem, Patrick

    2017-01-01

    IL-33 is a tissue-derived cytokine that induces and amplifies eosinophilic inflammation and has emerged as a promising new drug target for asthma and allergic disease. Common variants at IL33 and IL1RL1, encoding the IL-33 receptor ST2, associate with eosinophil counts and asthma. Through whole......-C associates with lower eosinophil counts (β = -0.21 SD, P = 2.5×10-16, N = 103,104), and reduced risk of asthma in Europeans (OR = 0.47; 95%CI: 0.32, 0.70, P = 1.8×10-4, N cases = 6,465, N controls = 302,977). Heterozygotes have about 40% lower total IL33 mRNA expression than non...

  7. The effects of Anadara granosa shell-Stichopus hermanni on bFGF expressions and blood vessel counts in the bone defect healing process of Wistar rats

    Directory of Open Access Journals (Sweden)

    Rima Parwati Sari

    2017-12-01

    Full Text Available Background: Bone damage can be caused by various factors with treatment usually involving graft materials being applied to the defective area. Moreover, in the bone defect healing process, blood vessels are also considered to be an important energy source for cell proliferation. One of the angiogenic factors playing an important role in blood vessel formation is basic fibroblast growth factor (bFGF. Furthermore, synthesized hydroxyapatite derived from Anadara granosa (AG shells constitutes one of the potential materials for use in bone graft. The gold sea cucumber genus Stichopus hermanni (SH possesses the ability to stimulate endothelial progenitor cells inducing bFGF. Purpose: This study aims to investigate the effects of AG shells and SH on bFGF expressions and blood vessel counts within the bone healing process. Methods: Twenty four male Wistar rats were divided into three groups, namely: a control group (C, a treatment group was administered with blood cockle shell (AG, and a treatment group with blood cockle shell and golden sea cucumber (AG+SH. Defects were made on their femurs measuring half the diameter of a circular, no. 018. bur These rats were subsequently sacrificed on day 7 after surgery. The expressions of bFGF were measured by means of IHC technique, while the number of blood vessels was quantified using HE technique. The resulting data was subjected to statistical analysis using an Anova test followed by an LSD test (p < 0.05. Results: The one-way Anova test results combined with those of an LSD test showed there to be significant differences in bFGF expressions and blood vessel counts between the control group (K and the treatment group (AG as well as between the treatment group (AG and the treatment group (AG+SH. Conclusions: A combination of Anadara granosa shell and Stichopus hermanni can increase the expression of bFGF and the number of blood vessels on day 7 during the bone healing process in Wistar rats.

  8. Correlation of the severity of atopic dermatitis with absolute eosinophil counts in peripheral blood and serum IgE levels

    Directory of Open Access Journals (Sweden)

    Dhar Sandipan

    2005-01-01

    Full Text Available BACKGROUND: Although a number of epidemiological studies, showing incidence and prevalence of atopic dermatitis, were available, scant attention has been paid to the correlation between the parameters of the disease like severity, absolute eosinophil count and IgE level, which has been known to be associated inconsistently. Hence this study was undertaken. METHODS: A total of 102 patients of atopic dermatitis, both children and adults, and 107 age matched controls were studied at the Pediatric Dermatology clinic, Institute of Child Health and department of Dermatology, AMRI-Apollo hospitals, Kolkata. RESULTS: The average age of onset of atopic dermatitis was observed to be 4.55 years. Both the average absolute eosinophil count and IgE levels in patients of atopic dermatitis were significantly higher than that of the controls. Each of these parameters showed significant correlation with severity of the disease and showed a nonhomogeneous distribution reflected by significant association with personal history of bronchial asthma and family history of atopy, when both parents were atopic. CONCLUSIONS: Our study shows that clinical activity of the disease as recorded by the "SCORAD" index can be used as an indicator of the hematological abnormalities as well as to some extent as a prognostic indicator. Family history of atopy correlates with the hematological abnormalities only if both parents are involved and bronchial asthma is the only associated atopic condition which correlates with the parameters of the disease .

  9. CD20 positivity and white blood cell count predict treatment outcomes in Philadelphia chromosome-negative acute lymphoblastic leukemia patients ineligible for pediatric-inspired chemotherapy.

    Science.gov (United States)

    Isshiki, Yusuke; Ohwada, Chikako; Sakaida, Emiko; Onoda, Masahiro; Aotsuka, Nobuyuki; Tanaka, Hiroaki; Fukazawa, Motoharu; Cho, Ryuko; Sugawara, Takeaki; Kawaguchi, Takeharu; Hara, Satoru; Yokota, Akira

    2017-11-01

    The efficacy of conventional chemotherapy and allogeneic hematopoietic stem cell transplantation (allo-HSCT) has been controversial as post-remission therapies for adult Philadelphia chromosome-negative acute lymphoblastic leukemia patients. We retrospectively analyzed 96 adolescent and adult cases of Philadelphia chromosome-negative acute lymphoblastic leukemia to evaluate whether allo-HSCT should be performed after first complete remission (1CR). In total, 34 patients received chemotherapy followed by allo-HSCT (HSCT group) and 62 received chemotherapy alone (chemotherapy group). No significant differences in the event-free survival (EFS) or overall survival were observed between the two groups. In the chemotherapy group, use of pediatric regimens was significantly associated with favorable EFS, while high white blood cell (WBC) count and CD20 positivity were associated with poor outcome. In patients who received pediatric regimens, subsequent allo-HSCT did not influence EFS. In patients who received conventional chemotherapy (adult regimen), subsequent allo-HSCT did not improve EFS. High WBC count and CD20 positivity were also significantly associated with poor EFS in patients who received adult regimens. Patients with low WBC count and absence of CD20 who received adult regimens did not benefit from allo-HSCT. Allo-HSCT may not be required in the pediatric regimen-eligible patients; however, pediatric regimen-ineligible patients with either CD20 positivity or high WBC count should receive allo-HSCT after achieving 1CR. This study was registered at http://www.umin.ac.jp/ctr/ as #C000016287. © The Author 2017. Published by Oxford University Press. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com

  10. The utility and cost-effectiveness of serial complete blood count monitoring in patients receiving radiation therapy for localized prostate cancer

    International Nuclear Information System (INIS)

    Blank, Kenneth; Cascardi, Michelle; Kao, Gary D.

    1997-01-01

    Purpose/Objective: It has been a standard practice in our department to monitor weekly complete blood counts (CBC) in patients receiving pelvic radiation therapy for prostate cancer. The utility and cost-effectiveness of this practice has not been analyzed. Material and Methods: We analyzed 1572 separate CBCs performed on 110 consecutive outpatients treated at the Veterans Administration Medical Center, Philadelphia, PA from June 1994 to June 1996 for localized prostate cancer. 92 of these patients fulfilled the study inclusion criteria of blood counts on at least four different weeks of treatment, a baseline hemoglobin (pretreatment or week one of radiation therapy), and at least one CBC after week four. Complete data was subjected to chi-square statistical analysis of factors including age, field size, concomitant hormonal therapy and the presence of hypertension or diabetes. Results: The mean hemoglobin level at the beginning of treatment of was 13.2 grams/dl (gms) and mean change in hemoglobin from baseline to the last week of treatment was - 0.53 gms (range +2.0 to -3.5 gm). No patients required blood transfusion or erythropoeitin treatment, and only five patients experienced declines of >2.0 gms (-2.1, -2.3, -2.5, -2.9 and -3.5). Two of these patients sustained the hemoglobin declines concomitantly with congestive heart failure requiring intensive care unit admission (suggesting fluid overload). The hemoglobin level in the remaining patients has returned to normal without treatment by one month after the end of radiation. No significant differences were found between the group of patients that dropped more than 1.0 gm (n=34) and the group that did not (n = 58) in field size (p0.08), presence of diabetes (p= 0.48) or hypertension (p= 0.43), concurrent or prior hormone therapy (p= 0.37), or age (p=0.83). No consistent trends in white blood cell or platelet counts could be detected during radiation and no patients had white blood cells counts fall below 2000/mm

  11. Early effects of treatment with radium and cobalt-60 gamma radiation on the proportions and absolute counts of T and B lymphocytes in peripheral blood of women with cervical carcinoma

    International Nuclear Information System (INIS)

    Pluzanska, A.; Robak, T.; Kuchowicz, W.; Bartuzel, T.; Studencki, E.; Zadrozna, O.; Mazurowa, A.

    1977-01-01

    In 20 women with cervical carcinoma the T and B lymphocyte counts were determined in peripheral blood. The determinations were carried out before starting treatment and immediately after radium therapy in a mean dose of 6573 mgh and then after full therapeutic dose of cobalt-60 radiation of 4000 R. For identification of T lymphocytes the rosette E test was used and lymphocytes B were identified by means of the EAC rosette test. Presence of immunoglobulins on lymphocytes B was determined as well. In women with cervical carcinoma the total lymphocyte count in 1 mm 3 of blood, the proportions and absolute counts of T and B lymphocytes were not different from those in healthy women. Immediately after radium therapy the lymphocyte count in peripheral blood fell which was due mainly to a fall of the total count and in the proportion of B lymphocytes. The proportion of lymphocytes T was unchanged and their quantitative fall was statistically not significant. After application of the total therapeutic dose of cobalt-60 radiation a further fall of lymphocyte count was observed, due to a fall of the absolute count of T and B lymphocytes. Their proportions were unchanged. (author)

  12. Estimation of the Hematological Change of Red Blood Cell and Platelet Count of Healthy Pregnant Women in Saudi Arabia

    Science.gov (United States)

    Hana, M. M.; Ramzun, M. R.; Nabela, Z.; Zahirah, N. A. N.; Razak, Nik Noor Ashikin Nik Abdul; Azhar, A. R.; Iskandar, S. M.; Nursakinah, S.

    2018-04-01

    Tremendous changes in hematological values were noticed throughout trimesters of pregnancy. This study is aimed to provide a reference for hematological values based on trimesters, focused on the parameter of red blood cell (RBCs) and platelets (PLTs). There were 4075 local Saudi pregnant women were involved, attending the Maternity and Children Hospital in Dammam and King Fahad University Hospital in Al-Khobar, between 2013 to 2015. The statistical analysis, such as frequency and descriptive were performed. Overall, this study revealed a decline in RBCs and PLTs throughout pregnancy. The RBC, HCT, MPV and MCH mean values were found decreases in the 2nd trimester but increased in the 3rd trimester. On the contrary, the MCV, MCHC, and RDW showed increases in the 2nd trimester and decreased in the 3rd trimester. The changes of the RBCs parameters in 3rd trimester compared to 1st trimester shows increased for MCV while the RBC, HCT, MCH and MCHC decreased. Besides that, most of the respondent suffering from anemia. The hematological values after delivery show decreased for RBC, HCT, MCV, MCH and MPV but an increase in the MCHC, RDW and PLT. Thus, it is highly recommended to request for a complete blood cell screening during pregnancy to provide a better healthcare of the maternal and fetus.

  13. Effects of Some Plant Extracts in Triticale-Based Broiler Diets on Growth Performance, E.Coli Counts in Intestine and Blood Parameters

    Directory of Open Access Journals (Sweden)

    Ergun Demir

    2016-10-01

    Full Text Available This study was conducted to determine the effect of using plant essential oils in triticale-based broiler diets as alternative to antimicrobial growth promotors (AGPs on growth, E.coli counts in small intestine and blood parameters. 720 male broiler chicks were randomly distributed to nine experimental groups with four replicates. The control group received the triticale-soybean meal basal diet. In the other treatment groups the basal diet was supplemented with one of the following; flavomycin, enzyme, flavomycin+enzyme, enzyme+thyme oil, enzyme+fennel oil, enzyme+bay leaf oil, enzyme+thyme oil+fennel oil and enzyme+thyme oil+fennel oil+bay leaf oil. Results showed that the weight gain and feed intake were not influenced by the treatments (P>0,05. The use of the combination of plant extracts significantly improved the feed conversion. Use of plant extracts in triticale-based broiler diets as an alternative to AGPs had no regular effect on E.coli count in small intestine segments (P>0,05. Feeding broiler chickens with the enzyme+thyme oil supplemented diets increased eritrocyte level in serum (P0,05 by the treatments. In conclusion, these plant ectracts can be also used with enzyme in triticale-based broiler diets as alternative to AGPs.

  14. Natural functional SNPs in miR-155 alter its expression level, blood cell counts and immune responses

    Directory of Open Access Journals (Sweden)

    Congcong Li

    2016-08-01

    Full Text Available miR-155 has been confirmed to be a key factor in immune responses in humans and other mammals. Therefore, investigation of variations in miR-155 could be useful for understanding the differences in immunity between individuals. In this study, four SNPs in miR-155 were identified in mice (Mus musculus and humans (Homo sapiens. In mice, the four SNPs were closely linked and formed two miR-155 haplotypes (A and B. Ten distinct types of blood parameters were associated with miR-155 expression under normal conditions. Additionally, 4 and 14 blood parameters were significantly different between these two genotypes under normal and lipopolysaccharide (LPS stimulation conditions, respectively. Moreover, the expression levels of miR-155, the inflammatory response to LPS stimulation and the lethal ratio following Salmonella typhimurium infection were significantly increased in mice harboring the AA genotype. Further, two SNPs, one in the loop region and the other near the 3' terminal of pre-miR-155, were confirmed to be responsible for the differential expression of miR-155 in mice. Interestingly, two additional SNPs, one in the loop region and the other in the middle of miR-155*, modulated the function of miR-155 in humans. Predictions of secondary RNA structure using RNAfold showed that these SNPs affected the structure of miR-155 in both mice and humans. Our results provide novel evidence of the natural functional SNPs of miR-155 in both mice and humans, which may affect the expression levels of mature miR-155 by modulating its secondary structure. The SNPs of human miR-155 may be considered as causal mutations for some immune-related diseases in the clinic. The two genotypes of mice could be used as natural models for studying the mechanisms of immune diseases caused by abnormal expression of miR-155 in humans.

  15. Counting carbohydrates

    Science.gov (United States)

    Carb counting; Carbohydrate-controlled diet; Diabetic diet; Diabetes-counting carbohydrates ... Many foods contain carbohydrates (carbs), including: Fruit and fruit juice Cereal, bread, pasta, and rice Milk and milk products, soy milk Beans, legumes, ...

  16. Influence of nutrient intake on antioxidant capacity, muscle damage and white blood cell count in female soccer players

    Directory of Open Access Journals (Sweden)

    Gravina Leyre

    2012-07-01

    Full Text Available Abstract Background Soccer is a form of exercise that induces inflammatory response, as well as an increase in free radicals potentially leading to muscle injury. Balanced nutritional intake provides important antioxidant vitamins, including vitamins A, C and E, which may assist in preventing exercise-related muscle damage. The purpose of the present study was to determine the effect of macro/micronutrient intake on markers of oxidative stress, muscle damage, inflammatory and immune response in female soccer players. Methods Twenty-eight female players belonging to two soccer teams of the same professional soccer club participated in this study after being informed about the aims and procedures and after delivering written consent. Each team completed an 8-day dietary record and played one competition match the same week. Participants were divided into two groups: the REC group (who complied with recommended intakes and the NO-REC group (who were not compliant. Laboratory blood tests were carried out to determine hematological, electrolytic and hormonal variables, as well as to monitor markers of cell damage and oxidative stress. Blood samples were obtained 24 h before, immediately after and 18 h after official soccer matches. Student t-test or Mann–Whitney U-test was used to compare both groups throughout the match. Results At rest, we observed that the REC group had higher levels of total antioxidant status (TAS, glutathione peroxidase (GPx, and lower levels of creatine kinase (CK and lactate dehydrogenase (LDH in comparison to the NO-REC group. Immediately after the match, levels of TAS, GPx, superoxide dismutase (SOD, LDH and % lymphocytes were higher and the % of neutrophils were lower in the REC group compared to the NO-REC group. These differences were also maintained 18 h post-match, only for TAS and GPx. Conclusions Our data reveal an association between nutritional intake and muscle damage, oxidative stress, immunity and inflammation

  17. Influence of nutrient intake on antioxidant capacity, muscle damage and white blood cell count in female soccer players

    Science.gov (United States)

    2012-01-01

    Background Soccer is a form of exercise that induces inflammatory response, as well as an increase in free radicals potentially leading to muscle injury. Balanced nutritional intake provides important antioxidant vitamins, including vitamins A, C and E, which may assist in preventing exercise-related muscle damage. The purpose of the present study was to determine the effect of macro/micronutrient intake on markers of oxidative stress, muscle damage, inflammatory and immune response in female soccer players. Methods Twenty-eight female players belonging to two soccer teams of the same professional soccer club participated in this study after being informed about the aims and procedures and after delivering written consent. Each team completed an 8-day dietary record and played one competition match the same week. Participants were divided into two groups: the REC group (who complied with recommended intakes) and the NO-REC group (who were not compliant). Laboratory blood tests were carried out to determine hematological, electrolytic and hormonal variables, as well as to monitor markers of cell damage and oxidative stress. Blood samples were obtained 24 h before, immediately after and 18 h after official soccer matches. Student t-test or Mann–Whitney U-test was used to compare both groups throughout the match. Results At rest, we observed that the REC group had higher levels of total antioxidant status (TAS), glutathione peroxidase (GPx), and lower levels of creatine kinase (CK) and lactate dehydrogenase (LDH) in comparison to the NO-REC group. Immediately after the match, levels of TAS, GPx, superoxide dismutase (SOD), LDH and % lymphocytes were higher and the % of neutrophils were lower in the REC group compared to the NO-REC group. These differences were also maintained 18 h post-match, only for TAS and GPx. Conclusions Our data reveal an association between nutritional intake and muscle damage, oxidative stress, immunity and inflammation markers. The benefit

  18. Counting cormorants

    DEFF Research Database (Denmark)

    Bregnballe, Thomas; Carss, David N; Lorentsen, Svein-Håkon

    2013-01-01

    This chapter focuses on Cormorant population counts for both summer (i.e. breeding) and winter (i.e. migration, winter roosts) seasons. It also explains differences in the data collected from undertaking ‘day’ versus ‘roost’ counts, gives some definitions of the term ‘numbers’, and presents two...

  19. Acute effects of resistance exercise and intermittent intense aerobic exercise on blood cell count and oxidative stress in trained middle-aged women.

    Science.gov (United States)

    Cardoso, A M; Bagatini, M D; Roth, M A; Martins, C C; Rezer, J F P; Mello, F F; Lopes, L F D; Morsch, V M; Schetinger, M R C

    2012-12-01

    The aim of this study was to compare the effect of an intermittent intense aerobic exercise session and a resistance exercise session on blood cell counts and oxidative stress parameters in middle-aged women. Thirty-four women were selected and divided into three groups: RE group (performing 60 min of resistance exercises, N = 12), spinning group (performing 60 min of spinning, N = 12), and control group (not exercising regularly, N = 10). In both exercise groups, lymphocytes and monocytes decreased after 1-h recuperation (post-exercise) compared to immediately after exercise (P exercise, in both exercised groups, a significant increase in TBARS (from 16.5 ± 2 to 25 ± 2 for the spinning group and from 18.6 ± 1 to 28.2 ± 3 nmol MDA/mL serum for the RE group) and protein carbonyl (from 1.0 ± 0.3 to 1.6 ± 0.2 for the spinning group and from 0.9 ± 0.2 to 1.5 ± 0.2 nmol/mg protein for the RE group) was observed (P exercise induces immune suppression and increases the production of reactive oxygen species, causing oxidative stress in middle-aged and trained women. Furthermore, we demonstrated that trained women show improved antioxidant capacity and lower oxidative damage than sedentary ones, demonstrating the benefits of chronic regular physical activity.

  20. Differential white blood cell count and type 2 diabetes: systematic review and meta-analysis of cross-sectional and prospective studies.

    Directory of Open Access Journals (Sweden)

    Effrossyni Gkrania-Klotsas

    2010-10-01

    Full Text Available Biological evidence suggests that inflammation might induce type 2 diabetes (T2D, and epidemiological studies have shown an association between higher white blood cell count (WBC and T2D. However, the association has not been systematically investigated.Studies were identified through computer-based and manual searches. Previously unreported studies were sought through correspondence. 20 studies were identified (8,647 T2D cases and 85,040 non-cases. Estimates of the association of WBC with T2D were combined using random effects meta-analysis; sources of heterogeneity as well as presence of publication bias were explored.The combined relative risk (RR comparing the top to bottom tertile of the WBC count was 1.61 (95% CI: 1.45; 1.79, p = 1.5*10(-18. Substantial heterogeneity was present (I(2 = 83%. For granulocytes the RR was 1.38 (95% CI: 1.17; 1.64, p = 1.5*10(-4, for lymphocytes 1.26 (95% CI: 1.02; 1.56, p = 0.029, and for monocytes 0.93 (95% CI: 0.68; 1.28, p = 0.67 comparing top to bottom tertile. In cross-sectional studies, RR was 1.74 (95% CI: 1.49; 2.02, p = 7.7*10(-13, while in cohort studies it was 1.48 (95% CI: 1.22; 1.79, p = 7.7*10(-5. We assessed the impact of confounding in EPIC-Norfolk study and found that the age and sex adjusted HR of 2.19 (95% CI: 1.74; 2.75 was attenuated to 1.82 (95% CI: 1.45; 2.29 after further accounting for smoking, T2D family history, physical activity, education, BMI and waist circumference.A raised WBC is associated with higher risk of T2D. The presence of publication bias and failure to control for all potential confounders in all studies means the observed association is likely an overestimate.

  1. Tower counts

    Science.gov (United States)

    Woody, Carol Ann; Johnson, D.H.; Shrier, Brianna M.; O'Neal, Jennifer S.; Knutzen, John A.; Augerot, Xanthippe; O'Neal, Thomas A.; Pearsons, Todd N.

    2007-01-01

    Counting towers provide an accurate, low-cost, low-maintenance, low-technology, and easily mobilized escapement estimation program compared to other methods (e.g., weirs, hydroacoustics, mark-recapture, and aerial surveys) (Thompson 1962; Siebel 1967; Cousens et al. 1982; Symons and Waldichuk 1984; Anderson 2000; Alaska Department of Fish and Game 2003). Counting tower data has been found to be consistent with that of digital video counts (Edwards 2005). Counting towers do not interfere with natural fish migration patterns, nor are fish handled or stressed; however, their use is generally limited to clear rivers that meet specific site selection criteria. The data provided by counting tower sampling allow fishery managers to determine reproductive population size, estimate total return (escapement + catch) and its uncertainty, evaluate population productivity and trends, set harvest rates, determine spawning escapement goals, and forecast future returns (Alaska Department of Fish and Game 1974-2000 and 1975-2004). The number of spawning fish is determined by subtracting subsistence, sport-caught fish, and prespawn mortality from the total estimated escapement. The methods outlined in this protocol for tower counts can be used to provide reasonable estimates ( plus or minus 6%-10%) of reproductive salmon population size and run timing in clear rivers. 

  2. Reticulocyte count

    Science.gov (United States)

    ... red blood cells being destroyed earlier than normal ( hemolytic anemia ) Bleeding Blood disorder in a fetus or newborn (erythroblastosis fetalis) Kidney disease, with increased production of a hormone called erythropoietin ...

  3. Performance evaluation of XN-1000 Sysmex blood cell count of low value of white blood cell%Sysmex XN-1000血细胞分析仪计数低值白细胞性能的评估

    Institute of Scientific and Technical Information of China (English)

    蒋清清; 马萍; 丁爽

    2016-01-01

    目的:探讨 Sysmex XN‐1000(后简称 XN‐1000)全自动血细胞分析仪检测白细胞计数(WBC)及分类的准确性。方法收集该院2015年1~4月门诊及住院患者及健康体检者共206例,根据人工镜检检测 WBC 结果分为高值组(WBC >10.0×109/L),健康组(4.0×109/L < WBC ≤10.0×109/L)和低值组(1.5×109/L < WBC ≤4.0×109/L)。再分别用 XN‐1000与Sysmex XE‐5000(后简称 XE‐5000)进行 WBC 并分类。采用统计学软件对3种方法的结果进行对比分析,并进行相关性分析。结果3种方法检测 WBC 结果比较,高值组和健康组差异无统计学意义(P>0.05),结果具有正相关性。低值组中,XN‐1000检测结果准确性与 XE‐5000差异无统计学意义(P>0.05),但是白细胞分类结果显著高于 XE‐5000(P<0.05);对于异常细胞,XN‐1000和 XE‐5000不能进行有效分类,仍需人工镜检进行分类。结论 XN‐1000全自动血细胞分析仪在 WBC 与 XE‐5000及人工镜检比较无差异统计学意义,在测定白细胞分类上 XN‐1000较 XE‐5000更准确(XN‐1000合格率91%,XE‐5000合格率63%),但仍不能完全替代人工镜检。对于异常细胞,XN‐1000不能有效分类,需与人工镜检结合。%Objective To investigate the accuracy of XN‐1000 automatic blood cell analyzer in detecting of white blood cell (WBC) count and classification .Methods A total of 206 cases including outpatients ,inpatients and health people were collected in the hospital from January to April 2015 .According to manual microscopy detection of white blood cell count results ,the cases were divided into three groups :high value of white blood cell(WBC was more than 10 .0 × 109 /L) group ,normal value of white blood cells group(WBC was more than 4 .0 × 109 /L but less than 10 .0 × 109 /L) and low value of white blood cell(WBC was more than 1 .5 × 109 /L

  4. Diagnostic value of serum procalcitonin levels in children with meningitis: a comparison with blood leukocyte count and C-reactive protein

    International Nuclear Information System (INIS)

    Ibrahim, K.A.; Wahab, A.A.A.; Ibrahim, A.S.

    2011-01-01

    Objectives: To determine the level of serum procalcitonin, blood leukocyte count (TLC) and C-reactive protein (CRP) in children with bacterial and non bacterial meningitis and document their efficacy in differential diagnosis. Also described are procalcitonin levels variation during treatment. Methods: From March 2005 to February 2008, we evaluated 38 clinically suspected meningitis patients in the paediatric departments, Al-Jedaany Hospital, Jeddah, KSA, for Serum procalcitonin, CRP, TLC and Lumbar punctures and CSF analysis. Patients were classified into bacterial meningitis group I (18) and non bacterial meningitis group II (20). Results: Serum PCT levels were significantly higher in bacterial meningitis (BM) 9 mean 4.8 +- 3.85 ng/ml (2.9-11.6)) compared with non bacterial meningitis (NBM) (mean 0.38 +- 0.25 ng/ml(0.31-0.61)) P< 0.001). Mean of all CSF parameters, TLC (15,000 +- 2,900 cell/ml(BM) and 9,500 +-1,105 cell/ml(NBM))and CRP (20 +- 6.8 mg/l (BM) and 12.5 +-12.0 mg/l(NBM))showed a zone of overlapping between the two groups. There is a positive correlation between serum PCT, TLC and CRP in bacterial and non bacterial meningitis cases but this relation becomes highly significant with bacterial meningitis positive group. Day 3 and day 6 treatment serum PCT was less than on admission levels (P<0.001). Conclusion: PCT can be used in the early diagnosis of bacterial meningitis and may be a useful adjunct in differentiating bacterial and non bacterial meningitis than CRP or TLC and diminishing the value of lumbar puncture performed 48-72 hours after admission to assess treatment efficacy. (author)

  5. Acute effects of resistance exercise and intermittent intense aerobic exercise on blood cell count and oxidative stress in trained middle-aged women

    Energy Technology Data Exchange (ETDEWEB)

    Cardoso, A.M. [Departamento de Química, Centro de Ciências Naturais e Exatas, Universidade Federal de Santa Maria, Santa Maria, RS (Brazil); Bagatini, M.D. [Curso de Enfermagem, Campus Chapecó, Universidade Federal da Fronteira Sul, Chapecó, SC (Brazil); Roth, M.A. [Departamento de Desportos Individuais, Centro de Educação Física e Desportos, Universidade Federal de Santa Maria, Santa Maria, RS (Brazil); Martins, C.C.; Rezer, J.F.P. [Departamento de Química, Centro de Ciências Naturais e Exatas, Universidade Federal de Santa Maria, Santa Maria, RS (Brazil); Mello, F.F. [Departamento de Desportos Individuais, Centro de Educação Física e Desportos, Universidade Federal de Santa Maria, Santa Maria, RS (Brazil); Lopes, L.F.D. [Departamento de Administração, Centro de Ciências Sociais e Humanas, Universidade Federal de Santa Maria, Santa Maria, RS (Brazil); Morsch, V.M.; Schetinger, M.R.C. [Departamento de Química, Centro de Ciências Naturais e Exatas, Universidade Federal de Santa Maria, Santa Maria, RS (Brazil)

    2012-10-26

    The aim of this study was to compare the effect of an intermittent intense aerobic exercise session and a resistance exercise session on blood cell counts and oxidative stress parameters in middle-aged women. Thirty-four women were selected and divided into three groups: RE group (performing 60 min of resistance exercises, N = 12), spinning group (performing 60 min of spinning, N = 12), and control group (not exercising regularly, N = 10). In both exercise groups, lymphocytes and monocytes decreased after 1-h recuperation (post-exercise) compared to immediately after exercise (P < 0.05). Immediately after exercise, in both exercised groups, a significant increase in TBARS (from 16.5 ± 2 to 25 ± 2 for the spinning group and from 18.6 ± 1 to 28.2 ± 3 nmol MDA/mL serum for the RE group) and protein carbonyl (from 1.0 ± 0.3 to 1.6 ± 0.2 for the spinning group and from 0.9 ± 0.2 to 1.5 ± 0.2 nmol/mg protein for the RE group) was observed (P < 0.05). A decrease in antioxidant activities (non-protein sulfhydryl, superoxide dismutase, catalase) was also demonstrated with a negative correlation between damage markers and antioxidant body defenses (P < 0.05). These results indicate that an acute bout of intermittent or anaerobic exercise induces immune suppression and increases the production of reactive oxygen species, causing oxidative stress in middle-aged and trained women. Furthermore, we demonstrated that trained women show improved antioxidant capacity and lower oxidative damage than sedentary ones, demonstrating the benefits of chronic regular physical activity.

  6. Acute effects of resistance exercise and intermittent intense aerobic exercise on blood cell count and oxidative stress in trained middle-aged women

    Directory of Open Access Journals (Sweden)

    A.M. Cardoso

    2012-12-01

    Full Text Available The aim of this study was to compare the effect of an intermittent intense aerobic exercise session and a resistance exercise session on blood cell counts and oxidative stress parameters in middle-aged women. Thirty-four women were selected and divided into three groups: RE group (performing 60 min of resistance exercises, N = 12, spinning group (performing 60 min of spinning, N = 12, and control group (not exercising regularly, N = 10. In both exercise groups, lymphocytes and monocytes decreased after 1-h recuperation (post-exercise compared to immediately after exercise (P < 0.05. Immediately after exercise, in both exercised groups, a significant increase in TBARS (from 16.5 ± 2 to 25 ± 2 for the spinning group and from 18.6 ± 1 to 28.2 ± 3 nmol MDA/mL serum for the RE group and protein carbonyl (from 1.0 ± 0.3 to 1.6 ± 0.2 for the spinning group and from 0.9 ± 0.2 to 1.5 ± 0.2 nmol/mg protein for the RE group was observed (P < 0.05. A decrease in antioxidant activities (non-protein sulfhydryl, superoxide dismutase, catalase was also demonstrated with a negative correlation between damage markers and antioxidant body defenses (P < 0.05. These results indicate that an acute bout of intermittent or anaerobic exercise induces immune suppression and increases the production of reactive oxygen species, causing oxidative stress in middle-aged and trained women. Furthermore, we demonstrated that trained women show improved antioxidant capacity and lower oxidative damage than sedentary ones, demonstrating the benefits of chronic regular physical activity.

  7. Acute effects of resistance exercise and intermittent intense aerobic exercise on blood cell count and oxidative stress in trained middle-aged women

    International Nuclear Information System (INIS)

    Cardoso, A.M.; Bagatini, M.D.; Roth, M.A.; Martins, C.C.; Rezer, J.F.P.; Mello, F.F.; Lopes, L.F.D.; Morsch, V.M.; Schetinger, M.R.C.

    2012-01-01

    The aim of this study was to compare the effect of an intermittent intense aerobic exercise session and a resistance exercise session on blood cell counts and oxidative stress parameters in middle-aged women. Thirty-four women were selected and divided into three groups: RE group (performing 60 min of resistance exercises, N = 12), spinning group (performing 60 min of spinning, N = 12), and control group (not exercising regularly, N = 10). In both exercise groups, lymphocytes and monocytes decreased after 1-h recuperation (post-exercise) compared to immediately after exercise (P < 0.05). Immediately after exercise, in both exercised groups, a significant increase in TBARS (from 16.5 ± 2 to 25 ± 2 for the spinning group and from 18.6 ± 1 to 28.2 ± 3 nmol MDA/mL serum for the RE group) and protein carbonyl (from 1.0 ± 0.3 to 1.6 ± 0.2 for the spinning group and from 0.9 ± 0.2 to 1.5 ± 0.2 nmol/mg protein for the RE group) was observed (P < 0.05). A decrease in antioxidant activities (non-protein sulfhydryl, superoxide dismutase, catalase) was also demonstrated with a negative correlation between damage markers and antioxidant body defenses (P < 0.05). These results indicate that an acute bout of intermittent or anaerobic exercise induces immune suppression and increases the production of reactive oxygen species, causing oxidative stress in middle-aged and trained women. Furthermore, we demonstrated that trained women show improved antioxidant capacity and lower oxidative damage than sedentary ones, demonstrating the benefits of chronic regular physical activity

  8. Cell type specific DNA methylation in cord blood: A 450K-reference data set and cell count-based validation of estimated cell type composition

    NARCIS (Netherlands)

    Gervin, K. (Kristina); Page, C.M. (Christian Magnus); H.C.D. Aass (Hans Christian Dalsbotten); M.A.E. Jansen (Michelle); Fjeldstad, H.E. (Heidi Elisabeth); B.K. Andreassen (Bettina Kulle); L. Duijts (Liesbeth); J.B.J. van Meurs (Joyce); M.C. van Zelm (Menno); V.W.V. Jaddoe (Vincent); Nordeng, H. (Hedvig); Knudsen, G.P. (Gunn Peggy); P. Magnus (Per); W. Nystad (Wenche); Staff, A.C. (Anne Cathrine); J.F. Felix (Janine); R. Lyle (Robert)

    2016-01-01

    textabstractEpigenome-wide association studies of prenatal exposure to different environmental factors are becoming increasingly common. These studies are usually performed in umbilical cord blood. Since blood comprises multiple cell types with specific DNA methylation patterns, confounding caused

  9. Counting probe

    International Nuclear Information System (INIS)

    Matsumoto, Haruya; Kaya, Nobuyuki; Yuasa, Kazuhiro; Hayashi, Tomoaki

    1976-01-01

    Electron counting method has been devised and experimented for the purpose of measuring electron temperature and density, the most fundamental quantities to represent plasma conditions. Electron counting is a method to count the electrons in plasma directly by equipping a probe with the secondary electron multiplier. It has three advantages of adjustable sensitivity, high sensitivity of the secondary electron multiplier, and directional property. Sensitivity adjustment is performed by changing the size of collecting hole (pin hole) on the incident front of the multiplier. The probe is usable as a direct reading thermometer of electron temperature because it requires to collect very small amount of electrons, thus it doesn't disturb the surrounding plasma, and the narrow sweep width of the probe voltage is enough. Therefore it can measure anisotropy more sensitively than a Langmuir probe, and it can be used for very low density plasma. Though many problems remain on anisotropy, computer simulation has been carried out. Also it is planned to provide a Helmholtz coil in the vacuum chamber to eliminate the effect of earth magnetic field. In practical experiments, the measurement with a Langmuir probe and an emission probe mounted to the movable structure, the comparison with the results obtained in reverse magnetic field by using a Helmholtz coil, and the measurement of ionic sound wave are scheduled. (Wakatsuki, Y.)

  10. Basal CD34+ Cell Count Predicts Peripheral Blood Stem Cell Mobilization in Healthy Donors after Administration of Granulocyte Colony-Stimulating Factor: A Longitudinal, Prospective, Observational, Single-Center, Cohort Study.

    Science.gov (United States)

    Martino, Massimo; Gori, Mercedes; Pitino, Annalisa; Gentile, Massimo; Dattola, Antonia; Pontari, Antonella; Vigna, Ernesto; Moscato, Tiziana; Recchia, Anna Grazia; Barilla', Santina; Tripepi, Giovanni; Morabito, Fortunato

    2017-07-01

    A longitudinal, prospective, observational, single-center, cohort study on healthy donors (HDs) was designed to identify predictors of CD34 + cells on day 5 with emphasis on the predictive value of the basal CD34 + cell count. As potential predictors of mobilization, age, sex, body weight, height, blood volume as well as white blood cell count, peripheral blood (PB) mononuclear cells, platelet count, hematocrit, and hemoglobin levels were considered. Two different evaluations of CD34 + cell counts were determined for each donor: baseline (before granulocyte colony-stimulating factor [G-CSF] administration) and in PB after G-CSF administration on the morning of the fifth day (day 5). A total of 128 consecutive HDs (66 males) with a median age of 43 years were enrolled. CD34 + levels on day 5 displayed a non-normal distribution, with a median value of 75.5 cells/µL. To account for the non-normal distribution of the dependent variable, a quantile regression analysis to predict CD34 + on day 5 using the baseline value of CD34 + as the key predictor was performed. On crude analysis, a baseline value of CD34 + ranging from .5 cells/µL to 1 cells/µL predicts a median value of 50 cells/µL on day 5; a value of 2 cells/µL predicts a median value of 70.7 cells/µL; a value of 3 cells/µL to 4 cells/µL predicts a median value of 91.3 cells/µL, and a value ≥ 5 predicts a median value of 112 cells/µL. In conclusion, the baseline PB CD34 + cell count correlates with the effectiveness of allogeneic PB stem cell mobilization and could be useful to plan the collection. Copyright © 2017 The American Society for Blood and Marrow Transplantation. Published by Elsevier Inc. All rights reserved.

  11. Effects of Agave tequilana fructans with different degree of polymerization profiles on the body weight, blood lipids and count of fecal Lactobacilli/Bifidobacteria in obese mice.

    Science.gov (United States)

    Márquez-Aguirre, Ana Laura; Camacho-Ruiz, Rosa Maria; Arriaga-Alba, Myriam; Padilla-Camberos, Eduardo; Kirchmayr, Manuel Reinhart; Blasco, José Luis; González-Avila, Marisela

    2013-08-01

    Fructans are dietary fibers with beneficial effects on the gastrointestinal physiology and offer a promising approach for the treatment of some metabolic disorders associated with obesity. In vitro and in vivo studies were developed to test the safety of fructans obtained from Agave tequilana Weber var. azul. Additionally, an in vivo experiment using a diet-induced obesity model was performed to compare the effect of agave fructans with different degree of polymerization (DP) profiles: agave fructans with DP > 10 (LcF), agave FOS with DP agave fructans with and without demineralization (dTF, TF) versus commercial chicory fructans (OraftiSynergy1™) on the body weight change, fat, total cholesterol, triglycerides and count of fecal Lactobacillus spp. and Bifidobacterium spp. Results showed that A. tequilana fructans were not mutagenic and were safe even at a dose of 5 g per kg b.w. Obese mice that received ScF showed a significant decrease in body weight gain, fat tissue and total cholesterol without increasing the count of fecal Bifidobacteria. Whereas, obese mice that received LcF and TF showed decreased triglycerides and an increased count of fecal Bifidobacteria. Interestingly, although obese mice that received dTF did not show changes in body weight gain, fat tissue, total cholesterol or triglycerides, they showed an increase in the count of Bifidobacteria. These results demonstrate that both the degree of polymerization and the demineralization process can influence the biological activity of agave fructans.

  12. Weekly monitoring of the effects of conventional external beam radiation therapy on patients with head and neck, chest, and pelvis cancer by means of blood cells count

    Energy Technology Data Exchange (ETDEWEB)

    Lundgren, Maria da Salete Fonseca dos Santos [Hospital Universitario Oswaldo Cruz, Recife, PE (Brazil). Radiotherapy Unit]. E-mail: salete@lundgren.med.br; Cavalcanti, Maria do Socorro de Mendonca [Universidade de Pernambuco, Recife, PE (Brazil); Sampaio, Divaldo de Almeida [Centro de Hematologia de Pernambuco (Hemope), Recife, PE (Brazil)

    2008-01-15

    Objective: To evaluate the necessity of weekly monitoring by means of leukocyte and platelet counts of patients with head and neck, chest, and pelvis cancer submitted to conventional radiotherapy. Materials and methods: A hundred and one adult patients with cancer of head and neck (n = 11), chest (n = 35) and pelvis (n = 55), submitted to radiotherapy were assessed by means of leukocyte and platelet counts on a weekly basis, with a comparison between the results before and during the treatment and in correlation with the area treated, patient's sex and age group. Results: The most significant decrease in leukocytes was observed in the fourth week, when lymphocytes, total leukocytes, neutrophils, monocytes and platelets presented a decrease of 53.5%, 26.8%, 19.4%, 22.2% and 14.6%, respectively, in comparison with the values found before the beginning of the therapy. Geometric means for pelvis during the treatment were lower than those for chest, and head and neck. Lymphocytes demonstrated to be more sensitive to radiation therapy. No alteration was found in leukocyte or platelet counts in correlation with patients' sex or age. Conclusion: Based on the results of the present study, weekly leukocyte and platelet counts do not seem to be useful in the assessment patients submitted to conventional radiotherapy for localized cancer. (author)

  13. Counting Possibilia

    Directory of Open Access Journals (Sweden)

    Alfredo Tomasetta

    2010-06-01

    Full Text Available Timothy Williamson supports the thesis that every possible entity necessarily exists and so he needs to explain how a possible son of Wittgenstein’s, for example, exists in our world:he exists as a merely possible object (MPO, a pure locus of potential. Williamson presents a short argument for the existence of MPOs: how many knives can be made by fitting together two blades and two handles? Four: at the most two are concrete objects, the others being merely possible knives and merely possible objects. This paper defends the idea that one can avoid reference and ontological commitment to MPOs. My proposal is that MPOs can be dispensed with by using the notion of rules of knife-making. I first present a solution according to which we count lists of instructions - selected by the rules - describing physical combinations between components. This account, however, has its own difficulties and I eventually suggest that one can find a way out by admitting possible worlds, entities which are more commonly accepted - at least by philosophers - than MPOs. I maintain that, in answering Williamson’s questions, we count classes of physically possible worlds in which the same instance of a general rule is applied.

  14. Platelet count

    Science.gov (United States)

    The normal number of platelets in the blood is 150,000 to 400,000 platelets per microliter (mcL) or 150 to 400 × 10 9 /L. Normal value ranges may vary slightly. Some lab use different measurements or ...

  15. Pneumatic tube system transport does not alter platelet function in optical and whole blood aggregometry, prothrombin time, activated partial thromboplastin time, platelet count and fibrinogen in patients on anti-platelet drug therapy

    Science.gov (United States)

    Enko, Dietmar; Mangge, Harald; Münch, Andreas; Niedrist, Tobias; Mahla, Elisabeth; Metzler, Helfried; Prüller, Florian

    2017-01-01

    Introduction The aim of this study was to assess pneumatic tube system (PTS) alteration on platelet function by the light transmission aggregometry (LTA) and whole blood aggregometry (WBA) method, and on the results of platelet count, prothrombin time (PT), activated partial thromboplastin time (APTT), and fibrinogen. Materials and methods Venous blood was collected into six 4.5 mL VACUETTE® 9NC coagulation sodium citrate 3.8% tubes (Greiner Bio-One International GmbH, Kremsmünster, Austria) from 49 intensive care unit (ICU) patients on dual anti-platelet therapy and immediately hand carried to the central laboratory. Blood samples were divided into 2 Groups: Group 1 samples (N = 49) underwent PTS (4 m/s) transport from the central laboratory to the distant laboratory and back to the central laboratory, whereas Group 2 samples (N = 49) were excluded from PTS forces. In both groups, LTA and WBA stimulated with collagen, adenosine-5’-diphosphate (ADP), arachidonic acid (AA) and thrombin-receptor-activated-peptide 6 (TRAP-6) as well as platelet count, PT, APTT, and fibrinogen were performed. Results No statistically significant differences were observed between blood samples with (Group 1) and without (Group 2) PTS transport (P values from 0.064 – 0.968). The AA-induced LTA (bias: 68.57%) exceeded the bias acceptance limit of ≤ 25%. Conclusions Blood sample transportation with computer controlled PTS in our hospital had no statistically significant effects on platelet aggregation determined in patients with anti-platelet therapy. Although AA induced LTA showed a significant bias, the diagnostic accuracy was not influenced. PMID:28392742

  16. Japanese Society for Laboratory Hematology flow cytometric reference method of determining the differential leukocyte count: external quality assurance using fresh blood samples.

    Science.gov (United States)

    Kawai, Y; Nagai, Y; Ogawa, E; Kondo, H

    2017-04-01

    To provide target values for the manufacturers' survey of the Japanese Society for Laboratory Hematology (JSLH), accurate standard data from healthy volunteers were needed for the five-part differential leukocyte count. To obtain such data, JSLH required an antibody panel that achieved high specificity (particularly for mononuclear cells) using simple gating procedures. We developed a flow cytometric method for determining the differential leukocyte count (JSLH-Diff) and validated it by comparison with the flow cytometric differential leukocyte count of the International Council for Standardization in Haematology (ICSH-Diff) and the manual differential count obtained by microscopy (Manual-Diff). First, the reference laboratory performed an imprecision study of JSLH-Diff and ICSH-Diff, as well as performing comparison among JSLH-Diff, Manual-Diff, and ICSH-Diff. Then two reference laboratories and seven participating laboratories performed imprecision and accuracy studies of JSLH-Diff, Manual-Diff, and ICSH-Diff. Simultaneously, six manufacturers' laboratories provided their own representative values by using automated hematology analyzers. The precision of both JSLH-Diff and ICSH-Diff methods was adequate. Comparison by the reference laboratory showed that all correlation coefficients, slopes and intercepts obtained by the JSLH-Diff, ICSH-Diff, and Manual-Diff methods conformed to the criteria. When the imprecision and accuracy of JSLH-Diff were assessed at seven laboratories, the CV% for lymphocytes, neutrophils, monocytes, eosinophils, and basophils was 0.5~0.9%, 0.3~0.7%, 1.7~2.6%, 3.0~7.9%, and 3.8~10.4%, respectively. More than 99% of CD45 positive leukocytes were identified as normal leukocytes by JSLH-Diff. When JSLH-Diff method were validated by comparison with Manual-Diff and ICSH-Diff, JSLH-Diff showed good performance as a reference method. © 2016 John Wiley & Sons Ltd.

  17. Blood

    Science.gov (United States)

    ... a reduced production of red blood cells, including: Iron deficiency anemia. Iron deficiency anemia is the most common type of anemia and ... inflammatory bowel disease are especially likely to have iron deficiency anemia. Anemia due to chronic disease. People with chronic ...

  18. Categorical counting.

    Science.gov (United States)

    Fetterman, J Gregor; Killeen, P Richard

    2010-09-01

    Pigeons pecked on three keys, responses to one of which could be reinforced after a few pecks, to a second key after a somewhat larger number of pecks, and to a third key after the maximum pecking requirement. The values of the pecking requirements and the proportion of trials ending with reinforcement were varied. Transits among the keys were an orderly function of peck number, and showed approximately proportional changes with changes in the pecking requirements, consistent with Weber's law. Standard deviations of the switch points between successive keys increased more slowly within a condition than across conditions. Changes in reinforcement probability produced changes in the location of the psychometric functions that were consistent with models of timing. Analyses of the number of pecks emitted and the duration of the pecking sequences demonstrated that peck number was the primary determinant of choice, but that passage of time also played some role. We capture the basic results with a standard model of counting, which we qualify to account for the secondary experiments. Copyright 2010 Elsevier B.V. All rights reserved.

  19. Incidence of spontaneous bacterial peritonitis in patients with ascites. Diagnostic value of white blood cell count and pH measurement in ascitic fluid

    DEFF Research Database (Denmark)

    Storgaard, J S; Svendsen, Jesper Hastrup; Hegnhøj, J

    1991-01-01

    During a 21-month period, 65 consecutive patients admitted with ascites were included in a prospective study of the incidence of spontaneous bacterial peritonitis, and paracentesis was performed on admission. The ascitic fluid was cultured, ascitic leucocytes were counted and pH was measured....... Bacterial growth was found in five patients with chronic liver disease, who were diagnosed as having spontaneous bacterial peritonitis (SBP), since no intra-abdominal focus could be demonstrated. Thus, the incidence of SBP in this material was 7.7% (95% confidence limits: 2.5-17%). SBP was caused...

  20. [Corrected count].

    Science.gov (United States)

    1991-11-27

    The data of the 1991 census indicated that the population count of Brazil fell short of a former estimate by 3 million people. The population reached 150 million people with an annual increase of 2%, while projections in the previous decade expected an increase of 2.48% to 153 million people. This reduction indicates more widespread use of family planning (FP) and control of fertility among families of lower social status as more information is being provided to them. However, the Ministry of Health ordered an investigation of foreign family planning organizations because it was suspected that women were forced to undergo tubal ligation during vaccination campaigns. A strange alliance of left wing politicians and the Roman Catholic Church alleges a conspiracy of international FP organizations receiving foreign funds. The FP strategies of Bemfam and Pro-Pater offer women who have little alternative the opportunity to undergo tubal ligation or to receive oral contraceptives to control fertility. The ongoing government program of distributing booklets on FP is feeble and is not backed up by an education campaign. Charges of foreign interference are leveled while the government hypocritically ignores the grave problem of 4 million abortions a year. The population is expected to continue to grow until the year 2040 and then to stabilize at a low growth rate of .4%. In 1980, the number of children per woman was 4.4 whereas the 1991 census figures indicate this has dropped to 3.5. The excess population is associated with poverty and a forsaken caste in the interior. The population actually has decreased in the interior and in cities with 15,000 people. The phenomenon of the drop of fertility associated with rural exodus is contrasted with cities and villages where the population is 20% less than expected.

  1. Positive correlation between postoperative tumor recurrence and changes in circulating tumor cell counts in pulmonary venous blood (pvCTC) during surgical manipulation in non-small cell lung cancer.

    Science.gov (United States)

    Hashimoto, Masaki; Tanaka, Fumihiro; Yoneda, Kazue; Takuwa, Teruhisa; Matsumoto, Seiji; Okumura, Yoshitomo; Kondo, Nobuyuki; Tsujimura, Tohru; Nakano, Takashi; Hasegawa, Seiki

    2018-01-01

    In non-small cell lung cancer (NSCLC), circulating tumor cells (CTC) are shed and circulate to the peripheral blood through the pulmonary vein. Previously, CTC count in pulmonary venous blood (pvCTC) was shown to significantly increase after surgical manipulation. Therefore, we assessed the correlation between the changes in the pvCTC count (ΔpvCTC) and clinical outcomes. Consecutive patients with peripheral-type, NSCLC, who underwent lobectomy or bi-lobectomy through open thoracotomy, were enrolled prospectively. Before and after lobectomy, 2.5 mL of blood was drawn from the associated lobar pulmonary vein (PV), and was served for the quantitative evaluation of CTC using the CellSearch ® system. The cut-off point of ΔpvCTC was determined according to clinical outcomes and ΔpvCTC using receiver operation characteristic (ROC) curve. Then the correlation between ΔpvCTC and clinical outcomes was evaluated by Kaplan-Meier analyses and log-rank test. In addition, the correlation between ΔpvCTC and perioperative variables was assessed. A total of 30 patients were enrolled, tumor recurrence occurred in 11 patients over a median follow-up of 64.4 months. Of these, 7 patients had distant metastasis and 4 had local recurrence. The median ΔpvCTC was 49 cells/2.5 mL, and pvCTC-count was increased during surgical manipulation in 24 patients (80%). We divided patients into two groups based on ΔpvCTC with the cut-off value as 119 cells/2.5 mL according to ROC curve. Significant shorter time to distant metastasis (TDM) (P=0.0123) was observed in high ΔpvCTC group (ΔpvCTC ≥119 cells/2.5 mL) than low ΔpvCTC group (ΔpvCTC <119 cells/ 2.5mL). Neither disease-free survival (DFS) nor overall survival (OS) was significantly correlated with ΔpvCTC. Increasing pvCTC count during surgical manipulation was significantly correlated with postoperative distant metastasis in completely resected NSCLC patients. Significant shorter TDM was observed in patient with high ΔpvCTC group.

  2. Mean Platelet Volume, Red Cell Distribution Width to Platelet Count Ratio, Globulin Platelet Index, and 16 Other Indirect Noninvasive Fibrosis Scores: How Much Do Routine Blood Tests Tell About Liver Fibrosis in Chronic Hepatitis C?

    Science.gov (United States)

    Thandassery, Ragesh B; Al Kaabi, Saad; Soofi, Madiha E; Mohiuddin, Syed A; John, Anil K; Al Mohannadi, Muneera; Al Ejji, Khalid; Yakoob, Rafie; Derbala, Moutaz F; Wani, Hamidullah; Sharma, Manik; Al Dweik, Nazeeh; Butt, Mohammed T; Kamel, Yasser M; Sultan, Khaleel; Pasic, Fuad; Singh, Rajvir

    2016-07-01

    Many indirect noninvasive scores to predict liver fibrosis are calculated from routine blood investigations. Only limited studies have compared their efficacy head to head. We aimed to compare these scores with liver biopsy fibrosis stages in patients with chronic hepatitis C. From blood investigations of 1602 patients with chronic hepatitis C who underwent a liver biopsy before initiation of antiviral treatment, 19 simple noninvasive scores were calculated. The area under the receiver operating characteristic curves and diagnostic accuracy of each of these scores were calculated (with reference to the Scheuer staging) and compared. The mean age of the patients was 41.8±9.6 years (1365 men). The most common genotype was genotype 4 (65.6%). Significant fibrosis, advanced fibrosis, and cirrhosis were seen in 65.1%, 25.6, and 6.6% of patients, respectively. All the scores except the aspartate transaminase (AST) alanine transaminase ratio, Pohl score, mean platelet volume, fibro-alpha, and red cell distribution width to platelet count ratio index showed high predictive accuracy for the stages of fibrosis. King's score (cutoff, 17.5) showed the highest predictive accuracy for significant and advanced fibrosis. King's score, Göteborg university cirrhosis index, APRI (the AST/platelet count ratio index), and Fibrosis-4 (FIB-4) had the highest predictive accuracy for cirrhosis, with the APRI (cutoff, 2) and FIB-4 (cutoff, 3.25) showing the highest diagnostic accuracy.We derived the study score 8.5 - 0.2(albumin, g/dL) +0.01(AST, IU/L) -0.02(platelet count, 10/L), which at a cutoff of >4.7 had a predictive accuracy of 0.868 (95% confidence interval, 0.833-0.904) for cirrhosis. King's score for significant and advanced fibrosis and the APRI or FIB-4 score for cirrhosis could be the best simple indirect noninvasive scores.

  3. Relative frequency of immature CD34+/CD90+ subset in peripheral blood following mobilization correlates closely and inversely with the absolute count of harvested stem cells in multiple myeloma patients

    Directory of Open Access Journals (Sweden)

    Balint Bela

    2017-01-01

    Full Text Available Background/Aim. Stem cells (SCs guarantee complete/longterm bone marrow (BM repopulation after SC-transplants. The aim of the study was to evaluate absolute count of total SCs (determined by ISHAGE-sequential-gating protocol – SCish and relative frequency of immature CD34+/CD90+ (CD90+SCish subset in peripheral blood (PB as predictive factors of mobilization and apheresis product (AP quality. Methods. Mobilization included chemotherapy and granulocytegrowth- factor (G-CSF. Harvesting was performed by Spectra- Optia-IDL-system. The SCsish were determined as a constitutional part of CD34+ cells in the “stem-cell-region” using FC- 500 flow-cytometer. In this study, the original ISHAGEsequential- gating protocol was modified by introduction of anti-CD90-PE monoclonal-antibody into the analysis of CD90 expression on SCish (CD90+SCish. The results were presented as a percentage of SCish per nucleated-cell count, absolute SCish count in μL of the PB or the AP, percentage of the CD90+SCish expressed to SCish and absolute CD90+SCish count in μL of the PB or the AP. Results. The absolute count of total SCish and CD90+SCish was significantly higher (p = 0.0007 and p = 0.0266, respectively in the AP than in the PB samples. The CD90+SCish/total SCish indexes from PB were higher than indexes from the AP (p = 0.039. The relative frequency of CD90+SCish showed a highly significant inverse correlation with the absolute count of total SCish in both, the PB and AP (p = 0.0003 and p = 0.0013 respectively. The relative frequency of CD90+SCish from the PB also showed a significant (p = 0.0002 inverse relationship with total SCish count in the AP. Patients with less than 10% CD90+SCish in the PB had evidently higher (p = 0.0025 total SCish count in the AP. Conclusion. We speculate that lower CD90+SCish yield in the AP is not a consequence of an inferior collection efficacy, but most likely a result of several still not fully resolved immature SC

  4. Elevated neutrophil and monocyte counts in peripheral blood are associated with poor survival in patients with metastatic melanoma: a prognostic model

    DEFF Research Database (Denmark)

    Schmidt, H; Bastholt, L; Geertsen, P

    2005-01-01

    factors in univariate analyses. Subsequently, a multivariate Cox's regression analysis identified elevated LDH (Pperformance status of 2 (P=0.008, hazard ratio 1.6) as independent prognostic factors for poor survival...... of several phase II protocols and the majority received treatment with intermediate dose subcutaneous IL-2 and interferon-alpha. Neutrophil and monocyte counts, lactate dehydrogenase (LDH), number of metastatic sites, location of metastases and performance status were all statistically significant prognostic...... survival of 12.6 months (95% confidence interval (CI), 11.4-13.8), 6.0 months (95% CI, 4.8-7.2) and 3.4 months (95% CI, 1.2-5.6), respectively. The low-risk group encompassed the majority of long-term survivors, whereas the patients in the high-risk group with a very poor prognosis should probably...

  5. Blood and Diversity

    Science.gov (United States)

    ... Drive Biomedical Services Hospital Partners Blood Products Blood Banking Resources Order Blood Products Invoice Central Case Reports ... app (over 1 million downloads and counting!) and online scheduler make it quick to set up your ...

  6. Hyperglycemia (High Blood Glucose)

    Medline Plus

    Full Text Available ... Your Carbs Count Glycemic Index Low-Calorie Sweeteners Sugar and Desserts Fitness Exercise & Type 1 Diabetes Get ... the technical term for high blood glucose (blood sugar). High blood glucose happens when the body has ...

  7. Hyperleucocytosis in paediatric acute myeloid leukaemia - the challenge of white blood cell counts above 200 × 10(9) /l. The NOPHO experience 1984-2014

    DEFF Research Database (Denmark)

    Zeller, Bernward; Glosli, Heidi; Forestier, Erik

    2017-01-01

    on very high white blood cell counts (WBC >200 × 10/l). Eighty-six patients (10%) had WBC 100-199 × 109 /l and 57 (6%) had WBC ≥200 × 109 /l. Patients with WBC ≥200 × 109 /l had a high frequency of t(9;11) and a paucity of trisomy 8. Due to the high frequency of deaths within the first 2 weeks (30% vs. 1......% for all others), overall survival in this group was inferior to patients with WBC vs. 61%). Main cause of early death was intracranial haemorrhage and leucostasis. Twenty-six per cent of these patients never started antileukaemic protocol therapy. Leukapheresis or exchange transfusion...... was used in 24% of patients with hyperleucocytosis without impact on survival. Patients with hyperleucocytosis surviving the first week had identical survival as patients with lower WBC. We conclude that death within the first days after diagnosis is the major challenge in patients with high WBC...

  8. Evaluation of Complete Blood Count Indices (NLR, PLR, MPV/PLT, and PLCRi) in Healthy Dogs, Dogs With Periodontitis, and Dogs With Oropharyngeal Tumors as Potential Biomarkers of Systemic Inflammatory Response.

    Science.gov (United States)

    Rejec, Ana; Butinar, Janos; Gawor, Jerzy; Petelin, Milan

    2017-12-01

    The aim of the study was to retrospectively assess complete blood count (CBC) indices of dogs with periodontitis (PD; n = 73) and dogs with oropharyngeal tumors (OT; n = 92) in comparison to CBC indices of healthy dogs (HD; n = 71). Neutrophil to lymphocyte ratio (NLR), platelet to lymphocyte ratio, mean platelet volume to platelet ratio, and platelet large cell ratio index (PLCRi) were evaluated as biomarkers of systemic inflammatory response provoked by PD and OT. Results of multivariable polytomous logistic regression analysis indicated no significant associations between CBC indices and PD. Both NLR and PLCRi were significantly higher in dogs with OT when compared to HD and dogs with PD and could, therefore, indicate a tumor-associated systemic inflammatory response. Additional studies of CBC indices, along with other biomarkers of systemic inflammatory response, are recommended to validate them as reliable indicators of clinical disease activity.

  9. A Microfluidic Cytometer for Complete Blood Count With a 3.2-Megapixel, 1.1- μm-Pitch Super-Resolution Image Sensor in 65-nm BSI CMOS.

    Science.gov (United States)

    Liu, Xu; Huang, Xiwei; Jiang, Yu; Xu, Hang; Guo, Jing; Hou, Han Wei; Yan, Mei; Yu, Hao

    2017-08-01

    Based on a 3.2-Megapixel 1.1- μm-pitch super-resolution (SR) CMOS image sensor in a 65-nm backside-illumination process, a lens-free microfluidic cytometer for complete blood count (CBC) is demonstrated in this paper. Backside-illumination improves resolution and contrast at the device level with elimination of surface treatment when integrated with microfluidic channels. A single-frame machine-learning-based SR processing is further realized at system level for resolution correction with minimum hardware resources. The demonstrated microfluidic cytometer can detect the platelet cells (< 2 μm) required in CBC, hence is promising for point-of-care diagnostics.

  10. Prediction of esophageal variceal bleeding in B-viral liver cirrhosis using the P2/MS noninvasive index based on complete blood counts.

    Science.gov (United States)

    Kim, Beom Kyung; Ahn, Sang Hoon; Han, Kwang-Hyub; Park, Jun Yong; Han, Min Seok; Jo, Jung Hyun; Kim, Ja Kyung; Lee, Kwan Sik; Chon, Chae Yoon; Kim, Do Young

    2012-01-01

    Periodic endoscopy for esophageal varices (EVs) and prophylactic treatment of high-risk EVs, i.e., medium/large EVs, small EVs with the red-color sign or decompensation, are recommended in cirrhotic patients. We assessed the cumulative risks for future EV bleeding using the following simple P2/MS index: (platelet count)2/[monocyte fraction (%) × segmented neutrophil fraction (%)]. We enrolled 475 consecutive B-viral cirrhosis patients for 4 years, none of whom experienced EV bleeding. All underwent laboratory work-ups, endoscopy and ultrasonography. Those with EV bleeding took a nonselective β-blocker as prophylaxis. The major endpoint was the first occurrence of EV bleeding, analyzed using the Kaplan-Meier and Cox regression methods. Among patients with EV bleeding (n = 131), 25 experienced their first EV bleeding during follow-up. To differentiate the risk for EV bleeding, we divided them into two subgroups according to their P2/MS value (subgroup 1: P2/MS ≥9 and subgroup 2: P2/MS P2/MS (p = 0.040) remained a significant predictor for EV bleeding along with large varix size (p = 0.015), red-color sign (p = 0.041) and Child-Pugh classification B/C (p = 0.001). In subgroup 1, the risk for EV bleeding was similar to that of patients with low-risk EVs (p = 0.164). The P2/MS is a reliable predictor for the risk of EV bleeding among patients with EV bleeding. According to risk stratification, different prophylactic treatments should be considered for the subgroup with a P2/MS <9. Copyright © 2012 S. Karger AG, Basel.

  11. Hyperglycemia (High Blood Glucose)

    Medline Plus

    Full Text Available ... Carbohydrate Counting Make Your Carbs Count Glycemic Index Low-Calorie Sweeteners Sugar and Desserts Fitness Exercise & Type ... Checking Your Blood Glucose A1C and eAG Hypoglycemia (Low blood glucose) Hyperglycemia (High blood glucose) Dawn Phenomenon ...

  12. Determining random counts in liquid scintillation counting

    International Nuclear Information System (INIS)

    Horrocks, D.L.

    1979-01-01

    During measurements involving coincidence counting techniques, errors can arise due to the detection of chance or random coincidences in the multiple detectors used. A method and the electronic circuits necessary are here described for eliminating this source of error in liquid scintillation detectors used in coincidence counting. (UK)

  13. Differential white cell count by centrifugal microfluidics.

    Energy Technology Data Exchange (ETDEWEB)

    Sommer, Gregory Jon; Tentori, Augusto M.; Schaff, Ulrich Y.

    2010-07-01

    We present a method for counting white blood cells that is uniquely compatible with centrifugation based microfluidics. Blood is deposited on top of one or more layers of density media within a microfluidic disk. Spinning the disk causes the cell populations within whole blood to settle through the media, reaching an equilibrium based on the density of each cell type. Separation and fluorescence measurement of cell types stained with a DNA dye is demonstrated using this technique. The integrated signal from bands of fluorescent microspheres is shown to be proportional to their initial concentration in suspension. Among the current generation of medical diagnostics are devices based on the principle of centrifuging a CD sized disk functionalized with microfluidics. These portable 'lab on a disk' devices are capable of conducting multiple assays directly from a blood sample, embodied by platforms developed by Gyros, Samsung, and Abaxis. [1,2] However, no centrifugal platform to date includes a differential white blood cell count, which is an important metric complimentary to diagnostic assays. Measuring the differential white blood cell count (the relative fraction of granulocytes, lymphocytes, and monocytes) is a standard medical diagnostic technique useful for identifying sepsis, leukemia, AIDS, radiation exposure, and a host of other conditions that affect the immune system. Several methods exist for measuring the relative white blood cell count including flow cytometry, electrical impedance, and visual identification from a stained drop of blood under a microscope. However, none of these methods is easily incorporated into a centrifugal microfluidic diagnostic platform.

  14. Radiological features of pulmonary tuberculosis in human immunodeficiency virus-infected patients: correlation with the blood CD4 cell count; Patrones radiologicos de la tuberculosis pulmonar en pacientes con infeccion VIH: correlacion con el indice de linfocitos CD4 en sangre

    Energy Technology Data Exchange (ETDEWEB)

    Isusi, M.; Eguidazu, J.; Oleaga, L.; Grande, D. [Hospital de Basurto. Bilbao (Spain)

    2000-07-01

    To describe the radiological features of pulmonary tuberculosis (TB) in patients infected with human immunodeficiency virus (HIV) and its correlation with the blood CD4 cell count. We present 44 HIV+patients, 24 with CD4 cell counts of less than 200 cells/mm''3 (group A) and 20 in whom the CD4 counts surpassed this level (group B). We also assessed the chest x-ray images to determine whether or not there was any correlation with the blood CD4 cell counts. Fisher's exact test was used for the statistical study of the differences in the radiological findings in the two groups. The incidence of atypical features was significantly greater in the patients with CD4 cell counts of less than 200 cells/mm''3 (group A) than in those with CD4 counts of over 200 cells/mm''3 (group B). Among HIV+patients, those with a more intact immune status were more likely to present lung x-ray images typical of post-primary TB, with cavitary lesions in upper lobes. The group of patients in whom the immune deficiency was more marked showed a greater incidence of atypical pulmonary findings, more characteristics of primary TB. (Author)

  15. Clean Hands Count

    Medline Plus

    Full Text Available ... Like this video? Sign in to make your opinion count. Sign in 131 2 Don't like this video? Sign in to make your opinion count. Sign in 3 Loading... Loading... Transcript The ...

  16. The Big Pumpkin Count.

    Science.gov (United States)

    Coplestone-Loomis, Lenny

    1981-01-01

    Pumpkin seeds are counted after students convert pumpkins to jack-o-lanterns. Among the activities involved, pupils learn to count by 10s, make estimates, and to construct a visual representation of 1,000. (MP)

  17. WBC (White Blood Cell) Differential Count

    Science.gov (United States)

    ... Pp 1003-1008. Harmening D. Clinical Hematology and Fundamentals of Hemostasis, Fifth Edition, F.A. Davis Company, Philadelphia, 2009, Pp 305-328. Henry's Clinical Diagnosis and Management by Laboratory Methods. 21st ed. McPherson R, Pincus ...

  18. Aqueous extract of Telfairia occidentalis leaves reduces blood sugar ...

    African Journals Online (AJOL)

    STORAGESEVER

    2008-07-18

    Jul 18, 2008 ... white blood cell counts), sperm parameters (sperm motility, viability and counts) and blood glucose were determined. ... cantly increased red blood cell count, white blood cell count, packed cell volume and .... improve sperm motility and fertility in smokers (Dawson et al., 1992) and boar (Ivos et al., 1971), ...

  19. Radiation counting statistics

    Energy Technology Data Exchange (ETDEWEB)

    Suh, M. Y.; Jee, K. Y.; Park, K. K.; Park, Y. J.; Kim, W. H

    1999-08-01

    This report is intended to describe the statistical methods necessary to design and conduct radiation counting experiments and evaluate the data from the experiment. The methods are described for the evaluation of the stability of a counting system and the estimation of the precision of counting data by application of probability distribution models. The methods for the determination of the uncertainty of the results calculated from the number of counts, as well as various statistical methods for the reduction of counting error are also described. (Author). 11 refs., 8 tabs., 8 figs.

  20. Radiation counting statistics

    Energy Technology Data Exchange (ETDEWEB)

    Suh, M. Y.; Jee, K. Y.; Park, K. K. [Korea Atomic Energy Research Institute, Taejon (Korea)

    1999-08-01

    This report is intended to describe the statistical methods necessary to design and conduct radiation counting experiments and evaluate the data from the experiments. The methods are described for the evaluation of the stability of a counting system and the estimation of the precision of counting data by application of probability distribution models. The methods for the determination of the uncertainty of the results calculated from the number of counts, as well as various statistical methods for the reduction of counting error are also described. 11 refs., 6 figs., 8 tabs. (Author)

  1. Radiation counting statistics

    International Nuclear Information System (INIS)

    Suh, M. Y.; Jee, K. Y.; Park, K. K.; Park, Y. J.; Kim, W. H.

    1999-08-01

    This report is intended to describe the statistical methods necessary to design and conduct radiation counting experiments and evaluate the data from the experiment. The methods are described for the evaluation of the stability of a counting system and the estimation of the precision of counting data by application of probability distribution models. The methods for the determination of the uncertainty of the results calculated from the number of counts, as well as various statistical methods for the reduction of counting error are also described. (Author). 11 refs., 8 tabs., 8 figs

  2. Concentração de anticoagulante, tempo e temperatura de armazenagem sobre os parâmetros hematológicos no hemograma automatizado Anticoagulant concentration, time and storage temperature on hematological parameters in automated blood count

    Directory of Open Access Journals (Sweden)

    Aécio Carlos de Oliveira

    2010-12-01

    concentration. Temperature and time also influenced the MCV, which showed a decrease in time 12 under temperature of 2°C to 8°C and an increase in time 24 and 48 at room temperature. Storage temperature influenced leukocytes and erythrocytes counts, which showed lower values at room temperature. Hemoglobin, PCV, platelet and PCT did not change significantly. The changes observed did not compromise the results obtained by automatic cell counter, showing that blood samples stored for two days remained in good condition for processing, especially when stored under refrigeration.

  3. Hemograma, sódio, potássio, cálcio, osmolalidade e viscosidade durante angiocardiografia pediátrica com ioxaglato Blood cell count, sodium, potassium, calcium, osmolality and viscosity, during pediatric angiocardiography with ioxaglate

    Directory of Open Access Journals (Sweden)

    Mauro Regis Silva Moura

    1998-04-01

    Full Text Available OBJETIVO: Os meios de contraste (MC introduzem alterações em alguns parâmetros sangüíneos, adquirindo, assim, mais importância na angiocardiografia pediátrica. MÉTODOS: Estudamos a presença e a severidade das mudanças no hematócrito, hemoglobina, leucócitos, sódio, potássio, cálcio, osmolalidade e viscosidade, em 35 crianças submetidas a angiocardiografia com ioxaglato, identificando, também, as variáveis independentes responsáveis por essas alterações. As amostras sangüíneas foram colhidas no início do procedimento (S1, no fim (S2 e 2h após (S3. RESULTADOS: Hematócrito: S1= 47,3±6,9%; S2= 40,7±7,4% (pPURPOSE: Children's blood changes during angiocardiography may not be only due to the contrast media (CM. METHODS: We studied the presence and severity of changes in those parameters in 35 pediatric patients undergoing angiocardiography with ioxaglate aiming to identify independent variables responsible for those changes. Blood samples were taken at the beginning of the procedure (S1, at the end (S2 and two hours later (S3. RESULTS: Hematocrit: S1= 47.3±6.9%; S2= 40.7± 7.4% (p<0.001, (related to the CM volume r=0.37, p<0.05. Hemoglobin: S1= 15±2.1g%; S2= 13.2±2.4g% (p<0.001, and S3= 12.7±2.5g% (NS. White blood cell count: S1= 7940±3040 leukocytes/mm³; S2= 6950± 2700/mm³ (NS; S3= 10830±4690 leukocytes/mm³, (p<0.001. Procedure duration (r=0.38, p<0.05 and 5% glucose fluid given between S2 and S3 (r=0.49, p<0.05 were isolated. Sodium: S1= 134.5±0.4mEq/L; S2= 130.7±0.4mEq/L (p<0.001 (due to 5% glucose fluid injected, r=0.61, p<0.01. Potassium: S1= 4.22±0.45mEq/L, S2= 3.83±0.4mEq/L (p<0.001. Calcium: S1= 9.13± 1.03mg%; S2= 8.4±0.91mg/dL. (related to the CM, r=0.43, p<0.01. Osmolality: S1= 293.3±12.5mOsm/kg; S2= 300.6±13.3mOsm/kg (p<0.001. Viscosity: S1= 3.36±0.81; S2= 3.09±0.74 (p<0.01; S3= 3.87±0.89, p<0.001. There was an indirect linear regression with the CM. CONCLUSION: There were profound

  4. Platelet Count and Plateletcrit

    African Journals Online (AJOL)

    strated that neonates with late onset sepsis (bacteremia after 3 days of age) had a dramatic increase in MPV and. PDW18. We hypothesize that as the MPV and PDW increase and platelet count and PCT decrease in sick children, intui- tively, the ratio of MPV to PCT; MPV to Platelet count,. PDW to PCT, PDW to platelet ...

  5. EcoCount

    Directory of Open Access Journals (Sweden)

    Phillip P. Allen

    2014-05-01

    Full Text Available Techniques that analyze biological remains from sediment sequences for environmental reconstructions are well established and widely used. Yet, identifying, counting, and recording biological evidence such as pollen grains remain a highly skilled, demanding, and time-consuming task. Standard procedure requires the classification and recording of between 300 and 500 pollen grains from each representative sample. Recording the data from a pollen count requires significant effort and focused resources from the palynologist. However, when an adaptation to the recording procedure is utilized, efficiency and time economy improve. We describe EcoCount, which represents a development in environmental data recording procedure. EcoCount is a voice activated fully customizable digital count sheet that allows the investigator to continuously interact with a field of view during the data recording. Continuous viewing allows the palynologist the opportunity to remain engaged with the essential task, identification, for longer, making pollen counting more efficient and economical. EcoCount is a versatile software package that can be used to record a variety of environmental evidence and can be installed onto different computer platforms, making the adoption by users and laboratories simple and inexpensive. The user-friendly format of EcoCount allows any novice to be competent and functional in a very short time.

  6. Clean Hands Count

    Medline Plus

    Full Text Available ... starting stop Loading... Watch Queue Queue __count__/__total__ It’s YouTube. Uninterrupted. Loading... Want music and videos with ... ads? Get YouTube Red. Working... Not now Try it free Find out why Close Clean Hands Count ...

  7. Counting It Twice.

    Science.gov (United States)

    Schattschneider, Doris

    1991-01-01

    Provided are examples from many domains of mathematics that illustrate the Fubini Principle in its discrete version: the value of a summation over a rectangular array is independent of the order of summation. Included are: counting using partitions as in proof by pictures, combinatorial arguments, indirect counting as in the inclusion-exclusion…

  8. Serum Copper Level Significantly Influences Platelet Count, Lymphocyte Count and Mean Cell Hemoglobin in Sickle Cell Anemia

    Directory of Open Access Journals (Sweden)

    Okocha Chide

    2015-12-01

    Full Text Available Background Changes in serum micro nutrients levels affect a number of critically important metabolic processes; these could potentially influence blood counts and ultimately disease presentation in patients with sickle cell anemia (SCA. Objectives To evaluate the influence of serum micro-nutrients levels; zinc, copper, selenium and magnesium on blood counts in steady state SCA patients. Methods A cross sectional study that involved 28 steady state adult SCA subjects. Seven milliliters (mls of blood was collected; 3 mls was for hemoglobin electrophoresis and full blood count determination while 4 mls was for measurement of serum micro nutrients levels, by the atomic absorption spectrophotometry. Correlation between serum micro-nutrient levels and blood counts was done by the Pearson’s linear regression. Ethical approval was obtained from the institutional review board and each participant gave informed consent. All data was analyzed by SPSS software version 20. Results There was a significant correlation between serum copper levels and mean cell hemoglobin (MCH, platelet and lymphocyte counts (r = 0.418; P = 0.02, r = -0.376; P = 0.04 and r = -0.383; P = 0.04, respectively. There were no significant correlations between serum levels of other micro nutrients (selenium, zinc and magnesium and blood counts. Conclusions Copper influences blood count in SCA patients probably by inducing red cell haemolysis, oxidant tissue damage and stimulating the immune system.

  9. Clean Hands Count

    Medline Plus

    Full Text Available ... Clean Hands Count Centers for Disease Control and Prevention (CDC) Loading... Unsubscribe from Centers for Disease Control and Prevention (CDC)? Cancel Unsubscribe Working... Subscribe Subscribed Unsubscribe 65K ...

  10. Clean Hands Count

    Medline Plus

    Full Text Available ... Clean Hands Count Centers for Disease Control and Prevention (CDC) Loading... Unsubscribe from Centers for Disease Control and Prevention (CDC)? Cancel Unsubscribe Working... Subscribe Subscribed Unsubscribe 66K ...

  11. Housing Inventory Count

    Data.gov (United States)

    Department of Housing and Urban Development — This report displays the data communities reported to HUD about the nature of their dedicated homeless inventory, referred to as their Housing Inventory Count (HIC)....

  12. Scintillation counting apparatus

    International Nuclear Information System (INIS)

    Noakes, J.E.

    1978-01-01

    Apparatus is described for the accurate measurement of radiation by means of scintillation counters and in particular for the liquid scintillation counting of both soft beta radiation and gamma radiation. Full constructional and operating details are given. (UK)

  13. Allegheny County Traffic Counts

    Data.gov (United States)

    Allegheny County / City of Pittsburgh / Western PA Regional Data Center — Traffic sensors at over 1,200 locations in Allegheny County collect vehicle counts for the Pennsylvania Department of Transportation. Data included in the Health...

  14. Counting Knights and Knaves

    Science.gov (United States)

    Levin,Oscar; Roberts, Gerri M.

    2013-01-01

    To understand better some of the classic knights and knaves puzzles, we count them. Doing so reveals a surprising connection between puzzles and solutions, and highlights some beautiful combinatorial identities.

  15. Clean Hands Count

    Medline Plus

    Full Text Available ... why Close Clean Hands Count Centers for Disease Control and Prevention (CDC) Loading... Unsubscribe from Centers for Disease Control and Prevention (CDC)? Cancel Unsubscribe Working... Subscribe Subscribed ...

  16. Clean Hands Count

    Medline Plus

    Full Text Available ... stop Loading... Watch Queue Queue __count__/__total__ It’s YouTube. Uninterrupted. Loading... Want music and videos with zero ads? Get YouTube Red. Working... Not now Try it free Find ...

  17. The Kruskal Count

    OpenAIRE

    Lagarias, Jeffrey C.; Rains, Eric; Vanderbei, Robert J.

    2001-01-01

    The Kruskal Count is a card trick invented by Martin J. Kruskal in which a magician "guesses" a card selected by a subject according to a certain counting procedure. With high probability the magician can correctly "guess" the card. The success of the trick is based on a mathematical principle related to coupling methods for Markov chains. This paper analyzes in detail two simplified variants of the trick and estimates the probability of success. The model predictions are compared with simula...

  18. Análisis de productividad, calidad y costos en laboratorios del primer nivel: la biometría hemática Analysis of productivity, quality and cost of first grade laboratories: complete blood count

    Directory of Open Access Journals (Sweden)

    Leticia Avila

    1999-04-01

    tiveram resultados confiáveis. Somente 20% dos laboratórios trabalharam com eficiência. CONCLUSÕES: Para solucionar os problemas encontrados será preciso usar estratégias integrais que comprometam os diferentes setores, mas de solução difícil. Recomenda-se analisar o custo-benefício de criar um laboratório central e deixar os demais laboratórios com a função exclusiva de selecionar amostras.OBJECTIVE: Assessment of productivity, quality and production costs and determination of the efficiency of top grade clinical laboratories in Mexico. METHODS: Ten laboratories were selected from among the total number (52 existing in Mexico City, and the Donabedian model of structure, process and results were applied. Blood count was selected as a tracer. RESULTS: The principal problems found were: inadequate distribution of trained human resources, poor glass material, inadequate analytic process and low productivity. These factors are reflected in the unit costs, which exceed reference laboratory costs by 200%. Only 50% of the laboratories analyzed generate reliable results. Only 20% of the laboratories studied operate efficiently. CONCLUSIONS: To solve the problems identified requires integral srategies at different levels. A specific recomendation for the improvement of quality and productivity is an assessment of the cost/benefit of creating a central laboratory and using the remaining sites exclusively for the collection of samples.

  19. Changes in total and differential white cell counts, total lymphocyte ...

    African Journals Online (AJOL)

    Background: Published reports on the possible changes in the various immune cell populations, especially the total lymphocyte and CD4 cell counts, during the menstrual cycle in Nigerian female subjects are relatively scarce. Aim: To determine possible changes in the total and differential white blood cell [WBC] counts, ...

  20. Total lymphocyte count and subpopulation lymphocyte counts in relation to dietary intake and nutritional status of peritoneal dialysis patients.

    Science.gov (United States)

    Grzegorzewska, Alicja E; Leander, Magdalena

    2005-01-01

    Dietary deficiency causes abnormalities in circulating lymphocyte counts. For the present paper, we evaluated correlations between total and subpopulation lymphocyte counts (TLC, SLCs) and parameters of nutrition in peritoneal dialysis (PD) patients. Studies were carried out in 55 patients treated with PD for 22.2 +/- 11.4 months. Parameters of nutritional status included total body mass, lean body mass (LBM), body mass index (BMI), and laboratory indices [total protein, albumin, iron, ferritin, and total iron binding capacity (TIBC)]. The SLCs were evaluated using flow cytometry. Positive correlations were seen between TLC and dietary intake of niacin; TLC and CD8 and CD16+56 counts and energy delivered from protein; CD4 count and beta-carotene and monounsaturated fatty acids 17:1 intake; and CD19 count and potassium, copper, vitamin A, and beta-carotene intake. Anorexia negatively influenced CD19 count. Serum albumin showed correlations with CD4 and CD19 counts, and LBM with CD19 count. A higher CD19 count was connected with a higher red blood cell count, hemoglobin, and hematocrit. Correlations were observed between TIBC and TLC and CD3 and CD8 counts, and between serum Fe and TLC and CD3 and CD4 counts. Patients with a higher CD19 count showed a better clinical-laboratory score, especially less weakness. Patients with a higher CD4 count had less expressed insomnia. Quantities of ingested vitamins and minerals influence lymphocyte counts in the peripheral blood of PD patients. Evaluation of TLC and SLCs is helpful in monitoring the effectiveness of nutrition in these patients.

  1. Alpha scintillation radon counting

    International Nuclear Information System (INIS)

    Lucas, H.F. Jr.

    1977-01-01

    Radon counting chambers which utilize the alpha-scintillation properties of silver activated zinc sulfide are simple to construct, have a high efficiency, and, with proper design, may be relatively insensitive to variations in the pressure or purity of the counter filling. Chambers which were constructed from glass, metal, or plastic in a wide variety of shapes and sizes were evaluated for the accuracy and the precision of the radon counting. The principles affecting the alpha-scintillation radon counting chamber design and an analytic system suitable for a large scale study of the 222 Rn and 226 Ra content of either air or other environmental samples are described. Particular note is taken of those factors which affect the accuracy and the precision of the method for monitoring radioactivity around uranium mines

  2. Principles of correlation counting

    International Nuclear Information System (INIS)

    Mueller, J.W.

    1975-01-01

    A review is given of the various applications which have been made of correlation techniques in the field of nuclear physics, in particular for absolute counting. Whereas in most cases the usual coincidence method will be preferable for its simplicity, correlation counting may be the only possible approach in such cases where the two radiations of the cascade cannot be well separated or when there is a longliving intermediate state. The measurement of half-lives and of count rates of spurious pulses is also briefly discussed. The various experimental situations lead to different ways the correlation method is best applied (covariance technique with one or with two detectors, application of correlation functions, etc.). Formulae are given for some simple model cases, neglecting dead-time corrections

  3. Interpretation of galaxy counts

    International Nuclear Information System (INIS)

    Tinsely, B.M.

    1980-01-01

    New models are presented for the interpretation of recent counts of galaxies to 24th magnitude, and predictions are shown to 28th magnitude for future comparison with data from the Space Telescope. The results supersede earlier, more schematic models by the author. Tyson and Jarvis found in their counts a ''local'' density enhancement at 17th magnitude, on comparison with the earlier models; the excess is no longer significant when a more realistic mixture of galaxy colors is used. Bruzual and Kron's conclusion that Kron's counts show evidence for evolution at faint magnitudes is confirmed, and it is predicted that some 23d magnitude galaxies have redshifts greater than unity. These may include spheroidal systems, elliptical galaxies, and the bulges of early-type spirals and S0's, seen during their primeval rapid star formation

  4. Computerized radioautographic grain counting

    International Nuclear Information System (INIS)

    McKanna, J.A.; Casagrande, V.A.

    1985-01-01

    In recent years, radiolabeling techniques have become fundamental assays in physiology and biochemistry experiments. They also have assumed increasingly important roles in morphologic studies. Characteristically, radioautographic analysis of structure has been qualitative rather than quantitative, however, microcomputers have opened the door to several methods for quantifying grain counts and density. The overall goal of this chapter is to describe grain counting using the Bioquant, an image analysis package based originally on the Apple II+, and now available for several popular microcomputers. The authors discuss their image analysis procedures by applying them to a study of development in the central nervous system

  5. Rainflow counting revisited

    Energy Technology Data Exchange (ETDEWEB)

    Soeker, H [Deutsches Windenergie-Institut (Germany)

    1996-09-01

    As state of the art method the rainflow counting technique is presently applied everywhere in fatigue analysis. However, the author feels that the potential of the technique is not fully recognized in wind energy industries as it is used, most of the times, as a mere data reduction technique disregarding some of the inherent information of the rainflow counting results. The ideas described in the following aim at exploitation of this information and making it available for use in the design and verification process. (au)

  6. Clean Hands Count

    Medline Plus

    Full Text Available ... Queue __count__/__total__ It’s YouTube. Uninterrupted. Loading... Want music and videos with zero ads? Get YouTube Red. ... 824 views 1:36 Wash 'Em - Hand Hygiene Music Video - Duration: 5:46. Jefferson Health 409,492 ...

  7. Clean Hands Count

    Medline Plus

    Full Text Available ... Queue __count__/__total__ It’s YouTube. Uninterrupted. Loading... Want music and videos with zero ads? Get YouTube Red. ... 786 views 1:36 Wash 'Em - Hand Hygiene Music Video - Duration: 5:46. Jefferson Health 413,702 ...

  8. Clean Hands Count

    Medline Plus

    Full Text Available ... Queue __count__/__total__ It’s YouTube. Uninterrupted. Loading... Want music and videos with zero ads? Get YouTube Red. ... 414 views 3:10 Wash 'Em - Hand Hygiene Music Video - Duration: 5:46. Thomas Jefferson University & Jefferson ...

  9. Clean Hands Count

    Medline Plus

    Full Text Available ... Queue __count__/__total__ It’s YouTube. Uninterrupted. Loading... Want music and videos with zero ads? Get YouTube Red. ... 869 views 1:36 Wash 'Em - Hand Hygiene Music Video - Duration: 5:46. Jefferson Health 410,052 ...

  10. Clean Hands Count

    Medline Plus

    Full Text Available ... Queue __count__/__total__ It’s YouTube. Uninterrupted. Loading... Want music and videos with zero ads? Get YouTube Red. ... 460 views 3:10 Wash 'Em - Hand Hygiene Music Video - Duration: 5:46. Thomas Jefferson University & Jefferson ...

  11. Clean Hands Count

    Medline Plus

    Full Text Available ... Queue __count__/__total__ It’s YouTube. Uninterrupted. Loading... Want music and videos with zero ads? Get YouTube Red. ... 741 views 3:10 Wash 'Em - Hand Hygiene Music Video - Duration: 5:46. Jefferson Health 410,052 ...

  12. Clean Hands Count

    Medline Plus

    Full Text Available ... Queue __count__/__total__ It’s YouTube. Uninterrupted. Loading... Want music and videos with zero ads? Get YouTube Red. ... 029 views 3:10 Wash 'Em - Hand Hygiene Music Video - Duration: 5:46. Jefferson Health 411,974 ...

  13. Clean Hands Count

    Medline Plus

    Full Text Available ... Queue __count__/__total__ It’s YouTube. Uninterrupted. Loading... Want music and videos with zero ads? Get YouTube Red. ... 396 views 3:10 Wash 'Em - Hand Hygiene Music Video - Duration: 5:46. Thomas Jefferson University & Jefferson ...

  14. Clean Hands Count

    Medline Plus

    Full Text Available ... Queue __count__/__total__ It’s YouTube. Uninterrupted. Loading... Want music and videos with zero ads? Get YouTube Red. ... 094 views 1:19 Wash 'Em - Hand Hygiene Music Video - Duration: 5:46. Jefferson Health 411,974 ...

  15. Clean Hands Count

    Medline Plus

    Full Text Available ... Queue __count__/__total__ It’s YouTube. Uninterrupted. Loading... Want music and videos with zero ads? Get YouTube Red. ... 319 views 3:10 Wash 'Em - Hand Hygiene Music Video - Duration: 5:46. Jefferson Health 410,052 ...

  16. Clean Hands Count

    Medline Plus

    Full Text Available ... Queue __count__/__total__ It’s YouTube. Uninterrupted. Loading... Want music and videos with zero ads? Get YouTube Red. ... 585 views 3:10 Wash 'Em - Hand Hygiene Music Video - Duration: 5:46. Jefferson Health 413,097 ...

  17. Detection and counting systems

    International Nuclear Information System (INIS)

    Abreu, M.A.N. de

    1976-01-01

    Detection devices based on gaseous ionization are analysed, such as: electroscopes ionization chambers, proportional counters and Geiger-Mueller counters. Scintillation methods are also commented. A revision of the basic concepts in electronics is done and the main equipment for counting is detailed. In the study of gama spectrometry, scintillation and semiconductor detectors are analysed [pt

  18. Clean Hands Count

    Medline Plus

    Full Text Available ... Queue __count__/__total__ It’s YouTube. Uninterrupted. Loading... Want music and videos with zero ads? Get YouTube Red. ... 384 views 1:19 Wash 'Em - Hand Hygiene Music Video - Duration: 5:46. Thomas Jefferson University & Jefferson ...

  19. Clean Hands Count

    Medline Plus

    Full Text Available ... Queue __count__/__total__ It’s YouTube. Uninterrupted. Loading... Want music and videos with zero ads? Get YouTube Red. ... 285 views 1:36 Wash 'Em - Hand Hygiene Music Video - Duration: 5:46. Jefferson Health 410,052 ...

  20. Clean Hands Count

    Medline Plus

    Full Text Available ... Queue __count__/__total__ It’s YouTube. Uninterrupted. Loading... Want music and videos with zero ads? Get YouTube Red. ... 033 views 1:36 Wash 'Em - Hand Hygiene Music Video - Duration: 5:46. Jefferson Health 410,052 ...

  1. Reticulocyte Count Test

    Science.gov (United States)

    ... htm. (2004 Summer). Immature Reticulocyte Fraction(IRF). The Pathology Center Newsletter v9(1). [On-line information]. Available ... Company, Philadelphia, PA [18th Edition]. Levin, M. (2007 March 8, Updated). Reticulocyte Count. MedlinePlus Medical Encyclopedia [On- ...

  2. Clean Hands Count

    Medline Plus

    Full Text Available ... is starting stop Loading... Watch Queue Queue __count__/__total__ It’s YouTube. Uninterrupted. Loading... Want music and videos ... empower patients to play a role in their care by asking or reminding healthcare providers to clean ...

  3. Radiation intensity counting system

    International Nuclear Information System (INIS)

    Peterson, R.J.

    1982-01-01

    A method is described of excluding the natural dead time of the radiation detector (or eg Geiger-Mueller counter) in a ratemeter counting circuit, thus eliminating the need for dead time corrections. Using a pulse generator an artificial dead time is introduced which is longer than the natural dead time of the detector. (U.K.)

  4. Clean Hands Count

    Medline Plus

    Full Text Available ... Queue __count__/__total__ It’s YouTube. Uninterrupted. Loading... Want music and videos with zero ads? Get YouTube Red. ... 043 views 1:36 Wash 'Em - Hand Hygiene Music Video - Duration: 5:46. Jefferson Health 411,292 ...

  5. Calorie count - fast food

    Science.gov (United States)

    ... GO About MedlinePlus Site Map FAQs Customer Support Health Topics Drugs & Supplements Videos & Tools Español You Are Here: Home → Medical Encyclopedia → Calorie count - fast food URL of this page: //medlineplus.gov/ency/patientinstructions/ ...

  6. Fast counting electronics for neutron coincidence counting

    International Nuclear Information System (INIS)

    Swansen, J.E.

    1987-01-01

    This patent describes a high speed circuit for accurate neutron coincidence counting comprising: neutron detecting means for providing an above-threshold signal upon neutron detection; amplifying means inputted by the neutron detecting means for providing a pulse output having a pulse width of about 0.5 microseconds upon the input of each above threshold signal; digital processing means inputted by the pulse output of the amplifying means for generating a pulse responsive to each input pulse from the amplifying means and having a pulse width of about 50 nanoseconds effective for processing an expected neutron event rate of about 1 Mpps: pulse stretching means inputted by the digital processing means for producing a pulse having a pulse width of several milliseconds for each pulse received form the digital processing means; visual indicating means inputted by the pulse stretching means for producing a visual output for each pulse received from the digital processing means; and derandomizing means effective to receive the 50 ns neutron event pulses from the digital processing means for storage at a rate up to the neutron event rate of 1 Mpps and having first counter means for storing the input neutron event pulses

  7. Haematological profile of cytomegalovirus antibody positive blood ...

    African Journals Online (AJOL)

    Screening forCMVantibodies was done using ELISA kit, manufactured by DIALAB, Austria. ( ). Complete blood count (PCV: Packed cell volume,WBC:White cell count-total and differential counts, and platelet counts) was done on all donors using automated coultermachine. Although the mean PCV value was higher in the ...

  8. CalCOFI Egg Counts

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Fish egg counts and standardized counts for eggs captured in CalCOFI icthyoplankton nets (primarily vertical [Calvet or Pairovet], oblique [bongo or ring nets], and...

  9. Counting statistics in radioactivity measurements

    International Nuclear Information System (INIS)

    Martin, J.

    1975-01-01

    The application of statistical methods to radioactivity measurement problems is analyzed in several chapters devoted successively to: the statistical nature of radioactivity counts; the application to radioactive counting of two theoretical probability distributions, Poisson's distribution law and the Laplace-Gauss law; true counting laws; corrections related to the nature of the apparatus; statistical techniques in gamma spectrometry [fr

  10. Do your syringes count?

    International Nuclear Information System (INIS)

    Brewster, K.

    2002-01-01

    Full text: This study was designed to investigate anecdotal evidence that residual Sestamibi (MIBI) activity vaned in certain situations. For rest studies different brands of syringes were tested to see if the residuals varied. The period of time MIBI doses remained in the syringe between dispensing and injection was also considered as a possible source of increased residual counts. Stress Mibi syringe residual activities were measured to assess if the method of stress test affected residual activity. MIBI was reconstituted using 13 Gbq of Technetium in 3mls of normal saline then boiled for 10 minutes. Doses were dispensed according to department protocol and injected via cannula. Residual syringes were collected for three syringe types. In each case the barrel and plunger were measured separately. As the syringe is flushed during the exercise stress test and not the pharmacological stress test the chosen method was recorded. No relationship was demonstrated between the time MIBI remained in a syringe prior to injection and residual activity. Residual activity was not affected by method of stress test used. Actual injected activity can be calculated if the amount of activity remaining in the syringe post injection is known. Imaging time can be adjusted for residual activity to optimise count statistics. Preliminary results in this study indicate there is no difference in residual activity between syringe brands.Copyright (2002) The Australian and New Zealand Society of Nuclear Medicine Inc

  11. Modal Logics with Counting

    Science.gov (United States)

    Areces, Carlos; Hoffmann, Guillaume; Denis, Alexandre

    We present a modal language that includes explicit operators to count the number of elements that a model might include in the extension of a formula, and we discuss how this logic has been previously investigated under different guises. We show that the language is related to graded modalities and to hybrid logics. We illustrate a possible application of the language to the treatment of plural objects and queries in natural language. We investigate the expressive power of this logic via bisimulations, discuss the complexity of its satisfiability problem, define a new reasoning task that retrieves the cardinality bound of the extension of a given input formula, and provide an algorithm to solve it.

  12. Digital coincidence counting

    International Nuclear Information System (INIS)

    Buckman, S.M.; Ius, D.

    1996-01-01

    This paper reports on the development of a digital coincidence-counting system which comprises a custom-built data acquisition card and associated PC software. The system has been designed to digitise the pulse-trains from two radiation detectors at a rate of 20 MSamples/s with 12-bit resolution. Through hardware compression of the data, the system can continuously record both individual pulse-shapes and the time intervals between pulses. Software-based circuits are used to process the stored pulse trains. These circuits are constructed simply by linking together icons representing various components such as coincidence mixers, time delays, single-channel analysers, deadtimes and scalers. This system enables a pair of pulse trains to be processed repeatedly using any number of different methods. Some preliminary results are presented in order to demonstrate the versatility and efficiency of this new method. (orig.)

  13. Digital coincidence counting

    Science.gov (United States)

    Buckman, S. M.; Ius, D.

    1996-02-01

    This paper reports on the development of a digital coincidence-counting system which comprises a custom-built data acquisition card and associated PC software. The system has been designed to digitise the pulse-trains from two radiation detectors at a rate of 20 MSamples/s with 12-bit resolution. Through hardware compression of the data, the system can continuously record both individual pulse-shapes and the time intervals between pulses. Software-based circuits are used to process the stored pulse trains. These circuits are constructed simply by linking together icons representing various components such as coincidence mixers, time delays, single-channel analysers, deadtimes and scalers. This system enables a pair of pulse trains to be processed repeatedly using any number of different methods. Some preliminary results are presented in order to demonstrate the versatility and efficiency of this new method.

  14. Counting statistics in low level radioactivity measurements fluctuating counting efficiency

    International Nuclear Information System (INIS)

    Pazdur, M.F.

    1976-01-01

    A divergence between the probability distribution of the number of nuclear disintegrations and the number of observed counts, caused by counting efficiency fluctuation, is discussed. The negative binominal distribution is proposed to describe the probability distribution of the number of counts, instead of Poisson distribution, which is assumed to hold for the number of nuclear disintegrations only. From actual measurements the r.m.s. amplitude of counting efficiency fluctuation is estimated. Some consequences of counting efficiency fluctuation are investigated and the corresponding formulae are derived: (1) for detection limit as a function of the number of partial measurements and the relative amplitude of counting efficiency fluctuation, and (2) for optimum allocation of the number of partial measurements between sample and background. (author)

  15. PERIPHERAL BLOOD FILM - A REVIEW FEATURE ARTICLES

    African Journals Online (AJOL)

    consent, blood sampling technique, transport to the laboratory and ... methanol or ethyl alcohol and stained with a. Rowmanosky ... blood count, erythrocyte sedimentation rate, red cell ... of the smear due to high humidity, uraemia, Malnutrition.

  16. Let's Make Data Count

    Science.gov (United States)

    Budden, A. E.; Abrams, S.; Chodacki, J.; Cruse, P.; Fenner, M.; Jones, M. B.; Lowenberg, D.; Rueda, L.; Vieglais, D.

    2017-12-01

    The impact of research has traditionally been measured by citations to journal publications and used extensively for evaluation and assessment in academia, but this process misses the impact and reach of data and software as first-class scientific products. For traditional publications, Article-Level Metrics (ALM) capture the multitude of ways in which research is disseminated and used, such as references and citations within social media and other journal articles. Here we present on the extension of usage and citation metrics collection to include other artifacts of research, namely datasets. The Make Data Count (MDC) project will enable measuring the impact of research data in a manner similar to what is currently done with publications. Data-level metrics (DLM) are a multidimensional suite of indicators measuring the broad reach and use of data as legitimate research outputs. By making data metrics openly available for reuse in a number of different ways, the MDC project represents an important first step on the path towards the full integration of data metrics into the research data management ecosystem. By assuring researchers that their contributions to scholarly progress represented by data corpora are acknowledged, data level metrics provide a foundation for streamlining the advancement of knowledge by actively promoting desirable best practices regarding research data management, publication, and sharing.

  17. LAWRENCE RADIATION LABORATORY COUNTING HANDBOOK

    Energy Technology Data Exchange (ETDEWEB)

    Group, Nuclear Instrumentation

    1966-10-01

    The Counting Handbook is a compilation of operational techniques and performance specifications on counting equipment in use at the Lawrence Radiation Laboratory, Berkeley. Counting notes have been written from the viewpoint of the user rather than that of the designer or maintenance man. The only maintenance instructions that have been included are those that can easily be performed by the experimenter to assure that the equipment is operating properly.

  18. SUMS Counts-Related Projects

    Data.gov (United States)

    Social Security Administration — Staging Instance for all SUMs Counts related projects including: Redeterminations/Limited Issue, Continuing Disability Resolution, CDR Performance Measures, Initial...

  19. Compton suppression gamma-counting: The effect of count rate

    Science.gov (United States)

    Millard, H.T.

    1984-01-01

    Past research has shown that anti-coincidence shielded Ge(Li) spectrometers enhanced the signal-to-background ratios for gamma-photopeaks, which are situated on high Compton backgrounds. Ordinarily, an anti- or non-coincidence spectrum (A) and a coincidence spectrum (C) are collected simultaneously with these systems. To be useful in neutron activation analysis (NAA), the fractions of the photopeak counts routed to the two spectra must be constant from sample to sample to variations must be corrected quantitatively. Most Compton suppression counting has been done at low count rate, but in NAA applications, count rates may be much higher. To operate over the wider dynamic range, the effect of count rate on the ratio of the photopeak counts in the two spectra (A/C) was studied. It was found that as the count rate increases, A/C decreases for gammas not coincident with other gammas from the same decay. For gammas coincident with other gammas, A/C increases to a maximum and then decreases. These results suggest that calibration curves are required to correct photopeak areas so quantitative data can be obtained at higher count rates. ?? 1984.

  20. Track counting in radon dosimetry

    International Nuclear Information System (INIS)

    Fesenbeck, Ingo; Koehler, Bernd; Reichert, Klaus-Martin

    2013-01-01

    The newly developed, computer-controlled track counting system is capable of imaging and analyzing the entire area of nuclear track detectors. The high optical resolution allows a new analysis approach for the process of automated counting using digital image processing technologies. This way, higher exposed detectors can be evaluated reliably by an automated process as well. (orig.)

  1. Galaxy number counts: Pt. 2

    International Nuclear Information System (INIS)

    Metcalfe, N.; Shanks, T.; Fong, R.; Jones, L.R.

    1991-01-01

    Using the Prime Focus CCD Camera at the Isaac Newton Telescope we have determined the form of the B and R galaxy number-magnitude count relations in 12 independent fields for 21 m ccd m and 19 m ccd m 5. The average galaxy count relations lie in the middle of the wide range previously encompassed by photographic data. The field-to-field variation of the counts is small enough to define the faint (B m 5) galaxy count to ±10 per cent and this variation is consistent with that expected from galaxy clustering considerations. Our new data confirm that the B, and also the R, galaxy counts show evidence for strong galaxy luminosity evolution, and that the majority of the evolving galaxies are of moderately blue colour. (author)

  2. Hanford whole body counting manual

    International Nuclear Information System (INIS)

    Palmer, H.E.; Brim, C.P.; Rieksts, G.A.; Rhoads, M.C.

    1987-05-01

    This document, a reprint of the Whole Body Counting Manual, was compiled to train personnel, document operation procedures, and outline quality assurance procedures. The current manual contains information on: the location, availability, and scope of services of Hanford's whole body counting facilities; the administrative aspect of the whole body counting operation; Hanford's whole body counting facilities; the step-by-step procedure involved in the different types of in vivo measurements; the detectors, preamplifiers and amplifiers, and spectroscopy equipment; the quality assurance aspect of equipment calibration and recordkeeping; data processing, record storage, results verification, report preparation, count summaries, and unit cost accounting; and the topics of minimum detectable amount and measurement accuracy and precision. 12 refs., 13 tabs

  3. The Copenhagen primary care differential count (CopDiff) database

    DEFF Research Database (Denmark)

    Andersen, Christen Bertel L; Siersma, V.; Karlslund, W.

    2014-01-01

    BACKGROUND: The differential blood cell count provides valuable information about a person's state of health. Together with a variety of biochemical variables, these analyses describe important physiological and pathophysiological relations. There is a need for research databases to explore assoc...... the construction of the Copenhagen Primary Care Differential Count database as well as the distribution of characteristics of the population it covers and the variables that are recorded. Finally, it gives examples of its use as an inspiration to peers for collaboration.......BACKGROUND: The differential blood cell count provides valuable information about a person's state of health. Together with a variety of biochemical variables, these analyses describe important physiological and pathophysiological relations. There is a need for research databases to explore...... Practitioners' Laboratory has registered all analytical results since July 1, 2000. The Copenhagen Primary Care Differential Count database contains all differential blood cell count results (n=1,308,022) from July 1, 2000 to January 25, 2010 requested by general practitioners, along with results from analysis...

  4. Effect of laser on human blood

    International Nuclear Information System (INIS)

    Abdalsamad, Amuna Nagash Mohammed

    2016-03-01

    In this work, the effect of He-Ne (632.8 nm), N2 (337.1 nm), LED (450 nm) on the human blood, and blood component was studied by using CBC machine ( complete blood count) and UV -visible spectroscopy. Blood samples platoon A+ were collected and irradiated for different periods of time (10 minute, 20 minute, and 30 minute), to varied types of light source ( He- Ne laser and LED). Blood parameters of samples were measured by using complete Blood Count Machine (CBC). The absorption spectrum of blood samples were examined by using UV-visible spectrometer. The obtained results have shown different values of Complete Blood Counts and absorption spectrum due to different laser types and periods of time. We conclude that the laser light has clear effect on blood samples. (Author)

  5. In vivo counting of uranium

    International Nuclear Information System (INIS)

    Palmer, H.E.

    1985-03-01

    A state-of-the-art radiation detector system consisting of six individually mounted intrinsic germanium planar detectors, each 20 cm 2 by 13 mm thick, mounted together such that the angle of the whole system can be changed to match the slope of the chest of the person being counted, is described. The sensitivity of the system for counting uranium and plutonium in vivo and the precedures used in calibrating the system are also described. Some results of counts done on uranium mill workers are presented. 15 figs., 2 tabs

  6. Make My Trip Count 2015

    Data.gov (United States)

    Allegheny County / City of Pittsburgh / Western PA Regional Data Center — The Make My Trip Count (MMTC) commuter survey, conducted in September and October 2015 by GBA, the Pittsburgh 2030 District, and 10 other regional transportation...

  7. Counting Triangles to Sum Squares

    Science.gov (United States)

    DeMaio, Joe

    2012-01-01

    Counting complete subgraphs of three vertices in complete graphs, yields combinatorial arguments for identities for sums of squares of integers, odd integers, even integers and sums of the triangular numbers.

  8. Counting Word Frequencies with Python

    Directory of Open Access Journals (Sweden)

    William J. Turkel

    2012-07-01

    Full Text Available Your list is now clean enough that you can begin analyzing its contents in meaningful ways. Counting the frequency of specific words in the list can provide illustrative data. Python has an easy way to count frequencies, but it requires the use of a new type of variable: the dictionary. Before you begin working with a dictionary, consider the processes used to calculate frequencies in a list.

  9. Liquid scintillation counting of chlorophyll

    International Nuclear Information System (INIS)

    Fric, F.; Horickova, B.; Haspel-Horvatovic, E.

    1975-01-01

    A precise and reproducible method of liquid scintillation counting was worked out for measuring the radioactivity of 14 C-labelled chlorophyll a and chlorophyll b solutions without previous bleaching. The spurious count rate caused by luminescence of the scintillant-chlorophyll system is eliminated by using a suitable scintillant and by measuring the radioactivity at 4 to 8 0 C after an appropriate time of dark adaptation. Bleaching of the chlorophyll solutions is necessary only for measuring of very low radioactivity. (author)

  10. 白细胞计数对B型急性主动脉夹层介入治疗患者的预后评估价值%White blood cell counts prediction prognosis of patients with type B acute aortic dissection after endovascular therapy

    Institute of Scientific and Technical Information of China (English)

    杜敏; 李东泽; 曹钰; 魏薇; 张海宏; 陈瑶; 梁镰静; 万智

    2017-01-01

    目的 探讨白细胞计数(white blood cell counts,WBCc)对介入治疗的Stanford B型急性主动脉夹层患者预后的评估价值.方法 收集2012年1月~2012年12月在四川大学华西医院确诊为Stanford B型急性主动脉夹层,并行介入治疗的患者.根据患者入院时白细胞计数水平,分为72例高WBCc组(WBC>10×109/L)和59例低WBCc组(WBC≤10×109/L).收集患者的基本临床资料,血液检查结果,主要心血管不良事件,院内及院外随访期间生存状态.主要终点事件为:院内及院外随访期间死亡事件.Kaplan-Meier生存分析及多因素COX回归分析评估白细胞计数与B型急性主动夹层患者死亡率的关系.结果 本研究共纳入患者131例,其中男性97例(74%),院内死亡率为9.9%,随访中位数时间2.1年,死亡率为16%,Kaplan-Meier生存曲线分析高白细胞计数组(>10×109/L)的累计生存率明显低于低白细胞计数组(76.4% vs 93.2%,P=0.007).多因素COX回归分析显示,入院时较高白细胞计数(>10×109/L)是介入治疗的B型AAD患者死亡率的独立危险因素(HR:3.667,95% CI:1.206-11.145,P=0.022).结论 白细胞计数可作为介入治疗B型急性主动脉夹层患者死亡风险的预测因素.%Objectives To assess the viability of using white blood cell counts (WBCc) as a prognostic measure for patients with Stanford type B acute aortic dissection (AAD) after endovascular therapy (EVT).Methods The clinical data were collected from post-EVT Stanford type B AAD diagnosed in the West China Hospital of Sichuan University from January 2012 to December.The patients were divided into high WBCc group(> 10 × 109/L) (72 cases) and low WBCc group(≤10× 109/L)(59 cases) based on their white blood cell counts levels on admission.Collected information included patient basic clinical data,blood test results,major adverse cardiovascular events and survival status during inpatient and out-patient follow-ups.The primary end points

  11. Importância clínica da dosagem de lactato e contagem de eritroblastos no sangue colhido no segmento placentário da veia umbilical para o diagnóstico de hipóxia-isquemia em prematuros Clinical value of lactate measurement and nucleated red blood cell counts in the placental segment of the umbilical vein of premature newborns for diagnosis of hypoxia-ischemia

    Directory of Open Access Journals (Sweden)

    Yvi Gea

    2007-04-01

    Full Text Available OBJETIVO: Determinar a validade clínica das dosagens de lactato e contagem de eritroblastos quando comparados com o excesso de bases (EB em sangue do segmento placentário da veia umbilical de prematuros. MÉTODOS: foram colhidas amostras de 25 prematuros, após ligadura e dequitação. Os prematuros foram seguidos até a alta. Estatística incluiu regressão linear, correlação de Spearman, curvas ROC, Teste de Fisher. RESULTADOS: Lactato mostrou boa correlação com pH e EB (p OBJECTIVE: To evaluate the clinical value of lactate measurement and nucleated red blood cell (NRBC counts when compared to base excess (BE in the blood collected from the placental segment of the umbilical vein. METHODS: 25 umbilical cords from premature babies were sampled after placental delivery and cord clamping. Babies were followed until discharge. Statistics involved linear regression, Spearman's correlation, ROC curves, and Fisher's exact test. RESULTS: The relationship between lactate in the umbilical vein blood and pH and BE was significant (p < 0.0001. A 4.04 mmol/L lactate level showed a sensitivity of 62.5% and a specificity of 94.1% in detecting pH <7.2 and BE < -10 mmol/L. NRBC counts were related to BE (p = 0.0095, but with a sensitivity of 37.5% and specificity of 82.4% in detecting BE < -10 mmol/L. CONCLUSIONS: Lactate is a valuable marker of fetal hypoxia when sampled from placental segment veins. NRBC counts demonstrated low sensitivity for the detection of acidosis.

  12. Standardization of 241Am by digital coincidence counting, liquid scintillation counting and defined solid angle counting

    International Nuclear Information System (INIS)

    Balpardo, C.; Capoulat, M.E.; Rodrigues, D.; Arenillas, P.

    2010-01-01

    The nuclide 241 Am decays by alpha emission to 237 Np. Most of the decays (84.6%) populate the excited level of 237 Np with energy of 59.54 keV. Digital coincidence counting was applied to standardize a solution of 241 Am by alpha-gamma coincidence counting with efficiency extrapolation. Electronic discrimination was implemented with a pressurized proportional counter and the results were compared with two other independent techniques: Liquid scintillation counting using the logical sum of double coincidences in a TDCR array and defined solid angle counting taking into account activity inhomogeneity in the active deposit. The results show consistency between the three methods within a limit of a 0.3%. An ampoule of this solution will be sent to the International Reference System (SIR) during 2009. Uncertainties were analysed and compared in detail for the three applied methods.

  13. Curative efficacy of Dezocine in treatment of receiving laparoscopic appendectomy and its effects on white blood cell count and C reactive protein%地佐辛用于腹腔镜阑尾术患者的临床效果及对白细胞计数和C反应蛋白的影响

    Institute of Scientific and Technical Information of China (English)

    袁飞; 金原野; 周金萍; 刘冬炎; 蔡璐

    2017-01-01

    Objective To study curative efficacy of dezocine in treatment of receiving laparoscopic appendectomy and its effects on white blood cell count and c reactive protein.Methods 90 patients of laparoscopic appendectomy who received therapy from January 2015 to October 2016 in our hospital were selected as research objects,according to random number table,those patients were divided into the observation group and the control group,45 cases in each group.The control group was treated with sufentanil, while the observation group was treated with dezocine.Then operation index, T0 (preoperative),T1(extubation),T2(after extubation) mean arterial pressure(MAP),heart rate(HR), respiration rate(RR),isual analogue scale/score ( VAS) , ramsay score ( RSS) , white blood cell count and c reactive protein of two groups after treatment were compared .Results After treatment, MAP,HR in the observation group were significantly lower than control group [(78.30 ±6.20)mmHg vs.(86.08 ±6.09)mmHg,(76.45 ±5.90)mmHg vs.(80.48 ±5.80)mmHg,(90.82 ±9.50)time/min vs.(96.73 ±9.83)time /min,(87.21 ±8.15)time /min vs.(93.59 ±9.90)time /min](P<0.05); VAS, RSS score were significantly lower than the control group[(2.60 ±0.70)score vs.(5.29 ±0.83)score,(3.53 ±0.92)score vs.(6.38 ± 1.21)score](P<0.05); White blood cell count, c reactive protein were significantly lower than the control group[(7.92 ±2.01) ×109/L vs.(14.98 ±2.11) ×109/L,(7.90 ±2.30)mg/L vs(12.46 ±3.10)mg/L](P<0.05).Conclusion Dezocine is well for receiving laparoscopic appendectomy, obvious analgesic effect, can significantly reduce the white blood cell count and c reactive protein.%目的 研究地佐辛用于腹腔镜阑尾术患者的临床效果及对白细胞计数和C反应蛋白的影响.方法 选取2015年1月~2016年10月绍兴第二医院接诊的90例行腹腔镜阑尾术患者作为研究对象,按照随机数表法分为观察组和对照组,每组各45例,对照组采用舒芬太尼治疗,观察

  14. Complete blood count changes in an individual with confirmed ...

    African Journals Online (AJOL)

    Her close contacts showed no evidence of Lassa virus infection. Conclusion: This report adds to the literature on the natural history of Lassa fever; and that individuals may survive Lassa fever with conservative management of symptoms of the disease and its complications. Keywords: Lassa fever; viral hemorrhagic fever, ...

  15. Smoking, allergy, and the differential white blood cell count.

    OpenAIRE

    Taylor, R G; Gross, E; Joyce, H; Holland, F; Pride, N B

    1985-01-01

    Dutch workers have proposed that people with asthma and those smokers who develop chronic airflow obstruction share a common allergic constitution. To study whether smoking itself is associated with indicators of allergy, we have examined 237 men aged 51-61 years (120 smokers, 73 ex-smokers, and 44 non-smokers) who were recruited to a long term study of lung function in 1974, at which time men with a clinical diagnosis of asthma were excluded. Smokers, ex-smokers, and non-smokers did not diff...

  16. Low Blood Cell Counts: Side Effect of Cancer Treatment

    Science.gov (United States)

    ... of Privacy Practices Notice of Nondiscrimination Manage Cookies Advertising Mayo Clinic is a not-for-profit organization and proceeds from Web advertising help support our mission. Mayo Clinic does not ...

  17. Relationships between blood cell counts and the density of malaria ...

    African Journals Online (AJOL)

    African Journal of Clinical and Experimental Microbiology. Journal Home · ABOUT THIS JOURNAL · Advanced Search · Current Issue · Archives · Journal Home > Vol 11, No 2 (2010) >. Log in or Register to get access to full text downloads.

  18. Hanford whole body counting manual

    International Nuclear Information System (INIS)

    Palmer, H.E.; Rieksts, G.A.; Lynch, T.P.

    1990-06-01

    This document describes the Hanford Whole Body Counting Program as it is administered by Pacific Northwest Laboratory (PNL) in support of the US Department of Energy--Richland Operations Office (DOE-RL) and its Hanford contractors. Program services include providing in vivo measurements of internally deposited radioactivity in Hanford employees (or visitors). Specific chapters of this manual deal with the following subjects: program operational charter, authority, administration, and practices, including interpreting applicable DOE Orders, regulations, and guidance into criteria for in vivo measurement frequency, etc., for the plant-wide whole body counting services; state-of-the-art facilities and equipment used to provide the best in vivo measurement results possible for the approximately 11,000 measurements made annually; procedures for performing the various in vivo measurements at the Whole Body Counter (WBC) and related facilities including whole body counts; operation and maintenance of counting equipment, quality assurance provisions of the program, WBC data processing functions, statistical aspects of in vivo measurements, and whole body counting records and associated guidance documents. 16 refs., 48 figs., 22 tabs

  19. The increase in leucocyte count during menstruation is a function of ...

    African Journals Online (AJOL)

    Menstruation is an endocrine mediated physiologic cyclical bleeding per vagina in a non-pregnant woman of the reproductive age group. Blood is a good culture medium for bacteria and as such, menstruation can affect leucocytes count. This study is aimed at evaluating leucocytes count during menstruation. Fifty-eight ...

  20. Quantitative clinical uptake measurements using conjugate counting

    International Nuclear Information System (INIS)

    Lathrop, K.A.; Bartlett, R.D.; Chen, C.T.; Chou, J.S.; Faulhaber, P.F.; Harper, P.V.; Stark, V.J.

    1986-01-01

    While the use of conjugate counting for determination of organ uptake in human subjects has been extensively described, in the present study the determination of the organ uptake of ortho-iodohippurate presented several opportunities for validation of the in vivo counting data. Ortho-iodohippurate is distributed in the extracellular space, is largely extracted on each pass through the kidneys, and is not significantly deiodinated in vivo. Thus, the kidney uptake rate should be proportional to the blood level, the appearance rate of activity in the bladder is equal to the disappearance rate from the kidneys, and direct measurement of activity in the urine after voiding provides an internal standard for imaging measurements of bladder activity. Since the activity levels in the kidneys, bladder, and remainder of the body changed fairly rapidly, especially in the first 20 to 30 minutes following injection, posterior images of the trunk including kidneys and bladder were obtained continuously using a gamma camera fitted with a diverging collimator for 30 minutes and then at intervals for several hours. Simultaneous conjugate counting determinations were made using a whole body scanning system previously described at these meetings. Imaging data corrected for decay and adjacent background were fitted by least squares methods to curves representing a sum of exponentials, and the curves were normalized to the conjugate uptake measurements. The uptake curves of the kidneys and bladder matched well with the direct measurements of the urinary excretion. Data were collected in 16 normal subjects, and the estimated absorbed dose was calculated for the kidneys, the bladder and the remainder of the body for seven radioisotopes of iodine. 4 references, 6 figures, 2 tables

  1. Temporal trends in sperm count

    DEFF Research Database (Denmark)

    Levine, Hagai; Jørgensen, Niels; Martino-Andrade, Anderson

    2017-01-01

    a predefined protocol 7518 abstracts were screened and 2510 full articles reporting primary data on SC were reviewed. A total of 244 estimates of SC and TSC from 185 studies of 42 935 men who provided semen samples in 1973-2011 were extracted for meta-regression analysis, as well as information on years.......006, respectively). WIDER IMPLICATIONS: This comprehensive meta-regression analysis reports a significant decline in sperm counts (as measured by SC and TSC) between 1973 and 2011, driven by a 50-60% decline among men unselected by fertility from North America, Europe, Australia and New Zealand. Because......BACKGROUND: Reported declines in sperm counts remain controversial today and recent trends are unknown. A definitive meta-analysis is critical given the predictive value of sperm count for fertility, morbidity and mortality. OBJECTIVE AND RATIONALE: To provide a systematic review and meta-regression...

  2. Bioquímica sérica e hemograma de bovinos antes e após a técnica de biópsia hepática Serum chemistry profile and complete blood count in cattle before and after liver biopsy technique

    Directory of Open Access Journals (Sweden)

    Rogério Martins Amorim

    2003-06-01

    Full Text Available Avaliaram-se os efeitos da técnica de biópsia hepática sobre as atividades séricas das enzimas gama glutamil transferase (GGT, aspartato amino transferase (AST, fosfatase alcalina (FA, hemograma e fibrinogênio em 36 novilhas Nelore. Os animais foram submetidos ao procedimento de colheita de fragmento hepático, utilizando-se agulha de biópsia para determinação dos elementos minerais. As avaliações da bioquímica sérica foram realizadas em 20 novilhas, sendo divididas em dois grupos. No grupo 1 (n=10, colheu-se sangue em tubos a vácuo sem anticoagulante, antes da realização da biópsia e 24h após, e no grupo 2 (n=10 antes da biópsia e 96h após. Os valores do hemograma e do fibrinogênio foram obtidos antes e 96h após a realização do procedimento (n=16. A atividade sérica da AST aumentou significativamente (54,4% 24h após a realização da biópsia, porém estava dentro dos valores de referência 96h após o procedimento. As atividades séricas da GGT e da FA não sofreram aumentos nas 24h e 96h após a biópsia. A proteína total apresentou aumento significativo de 0,24g/dL 96h após o procedimento. Os demais parâmetros avaliados permaneceram dentro dos valores normais para a espécie. Os resultados obtidos permitem concluir que a técnica de biópsia hepática empregada é segura e eficaz por não provocar dano hepático significativo e por obter rapidamente fragmentos adequados para análise bromatológica e histopatológica.The effects of liver biopsy technique on GGT (gama glutamil transferase, AST (aspartate amino transferase, FA (alcaline transferase serum activity, complete blood counting and fibrinogen were evaluated in 36 Nelore breed heifers. The animals were submitted to liver biopsy, using biopsy needle for mineral element determination. The biochemical profile evaluation were obtained in 20 heifers, being divided in two groups. In group 1 (n=10, blood was obtained with vacuum tubes without anticoagulant before

  3. Blood pressure

    Science.gov (United States)

    Normal blood pressure is important for proper blood flow to the body's organs and tissues. The force of the blood on the walls of the arteries is called blood pressure. Blood pressure is measured both as the heart ...

  4. Blood Types

    Science.gov (United States)

    ... blood, safe blood transfusions depend on careful blood typing and cross-matching. There are four major blood ... cause exceptions to the above patterns. ABO blood typing is not sufficient to prove or disprove paternity ...

  5. Photon-counting image sensors

    CERN Document Server

    Teranishi, Nobukazu; Theuwissen, Albert; Stoppa, David; Charbon, Edoardo

    2017-01-01

    The field of photon-counting image sensors is advancing rapidly with the development of various solid-state image sensor technologies including single photon avalanche detectors (SPADs) and deep-sub-electron read noise CMOS image sensor pixels. This foundational platform technology will enable opportunities for new imaging modalities and instrumentation for science and industry, as well as new consumer applications. Papers discussing various photon-counting image sensor technologies and selected new applications are presented in this all-invited Special Issue.

  6. Liquid scintillation, counting, and compositions

    International Nuclear Information System (INIS)

    Sena, E.A.; Tolbert, B.M.; Sutula, C.L.

    1975-01-01

    The emissions of radioactive isotopes in both aqueous and organic samples can be measured by liquid scintillation counting in micellar systems. The micellar systems are made up of scintillation solvent, scintillation solute and a mixture of surfactants, preferably at least one of which is relatively oil-soluble water-insoluble and another which is relatively water-soluble oil-insoluble

  7. Phase space quark counting rule

    International Nuclear Information System (INIS)

    Wei-gin, C.; Lo, S.

    1980-01-01

    A simple quark counting rule based on phase space consideration suggested before is used to fit all 39 recent experimental data points on inclusive reactions. Parameter free relations are found to agree with experiments. Excellent detail fits are obtained for 11 inclusive reactions

  8. Counting a Culture of Mealworms

    Science.gov (United States)

    Ashbrook, Peggy

    2007-01-01

    Math is not the only topic that will be discussed when young children are asked to care for and count "mealworms," a type of insect larvae (just as caterpillars are the babies of butterflies, these larvae are babies of beetles). The following activity can take place over two months as the beetles undergo metamorphosis from larvae to adults. As the…

  9. Counting problems for number rings

    NARCIS (Netherlands)

    Brakenhoff, Johannes Franciscus

    2009-01-01

    In this thesis we look at three counting problems connected to orders in number fields. First we study the probability that for a random polynomial f in Z[X] the ring Z[X]/f is the maximal order in Q[X]/f. Connected to this is the probability that a random polynomial has a squarefree

  10. On Counting the Rational Numbers

    Science.gov (United States)

    Almada, Carlos

    2010-01-01

    In this study, we show how to construct a function from the set N of natural numbers that explicitly counts the set Q[superscript +] of all positive rational numbers using a very intuitive approach. The function has the appeal of Cantor's function and it has the advantage that any high school student can understand the main idea at a glance…

  11. Logistic regression for dichotomized counts.

    Science.gov (United States)

    Preisser, John S; Das, Kalyan; Benecha, Habtamu; Stamm, John W

    2016-12-01

    Sometimes there is interest in a dichotomized outcome indicating whether a count variable is positive or zero. Under this scenario, the application of ordinary logistic regression may result in efficiency loss, which is quantifiable under an assumed model for the counts. In such situations, a shared-parameter hurdle model is investigated for more efficient estimation of regression parameters relating to overall effects of covariates on the dichotomous outcome, while handling count data with many zeroes. One model part provides a logistic regression containing marginal log odds ratio effects of primary interest, while an ancillary model part describes the mean count of a Poisson or negative binomial process in terms of nuisance regression parameters. Asymptotic efficiency of the logistic model parameter estimators of the two-part models is evaluated with respect to ordinary logistic regression. Simulations are used to assess the properties of the models with respect to power and Type I error, the latter investigated under both misspecified and correctly specified models. The methods are applied to data from a randomized clinical trial of three toothpaste formulations to prevent incident dental caries in a large population of Scottish schoolchildren. © The Author(s) 2014.

  12. Vote Counting as Mathematical Proof

    DEFF Research Database (Denmark)

    Schürmann, Carsten; Pattinson, Dirk

    2015-01-01

    then consists of a sequence (or tree) of rule applications and provides an independently checkable certificate of the validity of the result. This reduces the need to trust, or otherwise verify, the correctness of the vote counting software once the certificate has been validated. Using a rule...

  13. Counting SET-free sets

    OpenAIRE

    Harman, Nate

    2016-01-01

    We consider the following counting problem related to the card game SET: How many $k$-element SET-free sets are there in an $n$-dimensional SET deck? Through a series of algebraic reformulations and reinterpretations, we show the answer to this question satisfies two polynomiality conditions.

  14. Repeatability of differential goat bulk milk culture and associations with somatic cell count, total bacterial count, and standard plate count

    OpenAIRE

    Koop, G.; Dik, N.; Nielen, M.; Lipman, L.J.A.

    2010-01-01

    The aims of this study were to assess how different bacterial groups in bulk milk are related to bulk milk somatic cell count (SCC), bulk milk total bacterial count (TBC), and bulk milk standard plate count (SPC) and to measure the repeatability of bulk milk culturing. On 53 Dutch dairy goat farms, 3 bulk milk samples were collected at intervals of 2 wk. The samples were cultured for SPC, coliform count, and staphylococcal count and for the presence of Staphylococcus aureus. Furthermore, SCC ...

  15. INTRAOPERATIVE PREDONATION CONTRIBUTES TO BLOOD SAVING

    NARCIS (Netherlands)

    SCHONBERGER, JPAM; BREDEE, JJ; TJIAN, D; EVERTS, PAM; WILDEVUUR, CRH

    1993-01-01

    The merits of reinfusing prebypass-removed autologous blood (intraoperative predonation) to salvage blood and improve postoperative hemostasis are still debated, specifically for patients at a higher risk for bleeding. To evaluate the effect of intraoperative predonation on the platelet count, blood

  16. Feasibility study of white blood cell count in cerebrospinal fluid and hydrothorax and ascites with Sysmex ;XN-1000 hematology analyzer%SYSMEX XN-1000血球仪在脑脊液和胸腹水白细胞计数中的可行性探讨

    Institute of Scientific and Technical Information of China (English)

    叶小英; 范春丽; 陆敏; 卞洁

    2016-01-01

    Objective To analyze the feasibility of using body fluid module of Sysmex XN-1000 hematology analyzer for white blood cell count in the cerebrospinal fluid (CSF), hydrothorax and ascites. Methods Microscope method and Sysmex XN-1000 hematology analyzer were used to analyze 183 samples of CSF, hydrothorax and ascites at the same time. The measured results were divided into three groups:group A:0~1 000×106/L, B:1 001~5 000×106/L, C:>5 000×106/L. The results were statistically analyzed. Results Compared with the results of microscope, the results of Sysmex XN-1000 hematology analyzer showed no statistically significant difference (P>0.05). The correlation coeffi-cients of group A, B, C were 0.993, 0.984, 0.996, with the regression equation of y=1.007x-1.072, y=1.003+19.776x, y=1.241-1 419.365x, respectively. Conclusion The body fluid module of Sysmex XN-1000 hematology analyzer can be used for white blood cell count in clinical CSF and hydrothorax and ascites, with simple operation and reliable results. When the instrument is alarmed on the sample test, we should use manual microscopy review to improve the veracity and reliability of the results.%目的:探讨SYSMEX XN-1000血液分析仪(简称SYSMEX XN-1000)的体液模式在脑脊液和胸腹水白细胞计数中应用的可行性。方法分别采用手工显微镜镜检法和SYSMEX XN-1000对183例脑脊液和胸腹水标本进行白细胞计数,将所测结果按A:(0~1000)×106/L,B:(1001~5000)×106/L,C:>5000×106/L分为三组,分别进行统计学分析。结果与手工显微镜镜检法相比,SYSMEX XN-1000所测结果差异无统计学意义(P>0.05)。A、B、C三组的相关系数分别为0.993、0.984、0.996,A组回归方程为y=1.007x-1.072,B组回归方程为y=1.003x+19.776,C组回归方程为y=1.241x-1419.365。结论 SYSMEX XN-1000血液分析仪可用于临床脑脊液和胸腹水中白细胞计数,其操作简单易行,结果稳定可靠,但如果仪器进行样品

  17. Theory of photoelectron counting statistics

    International Nuclear Information System (INIS)

    Blake, J.

    1980-01-01

    The purpose of the present essay is to provide a detailed analysis of those theoretical aspects of photoelectron counting which are capable of experimental verification. Most of our interest is in the physical phenomena themselves, while part is in the mathematical techniques. Many of the mathematical methods used in the analysis of the photoelectron counting problem are generally unfamiliar to physicists interested in the subject. For this reason we have developed the essay in such a fashion that, although primary interest is focused on the physical phenomena, we have also taken pains to carry out enough of the analysis so that the reader can follow the main details. We have chosen to present a consistently quantum mechanical version of the subject, in that we follow the Glauber theory throughout. (orig./WL)

  18. Bayesian Kernel Mixtures for Counts.

    Science.gov (United States)

    Canale, Antonio; Dunson, David B

    2011-12-01

    Although Bayesian nonparametric mixture models for continuous data are well developed, there is a limited literature on related approaches for count data. A common strategy is to use a mixture of Poissons, which unfortunately is quite restrictive in not accounting for distributions having variance less than the mean. Other approaches include mixing multinomials, which requires finite support, and using a Dirichlet process prior with a Poisson base measure, which does not allow smooth deviations from the Poisson. As a broad class of alternative models, we propose to use nonparametric mixtures of rounded continuous kernels. An efficient Gibbs sampler is developed for posterior computation, and a simulation study is performed to assess performance. Focusing on the rounded Gaussian case, we generalize the modeling framework to account for multivariate count data, joint modeling with continuous and categorical variables, and other complications. The methods are illustrated through applications to a developmental toxicity study and marketing data. This article has supplementary material online.

  19. Accuracy of Platelet Counting by Optical and Impedance Methods in Patients with Thrombocytopaenia and Microcytosis

    Directory of Open Access Journals (Sweden)

    Mohamed-Rachid Boulassel

    2015-11-01

    Full Text Available Objectives: Obtaining accurate platelet counts in microcytic blood samples is challenging, even with the most reliable automated haematology analysers. The CELL-DYN™ Sapphire (Abbott Laboratories, Chicago, Illinois, USA analyser uses both optical density and electronic impedance methods for platelet counting. This study aimed to evaluate the accuracy of optical density and electrical impedance methods in determining true platelet counts in thrombocytopaenic samples with microcytosis as defined by low mean corpuscular volume (MCV of red blood cells. Additionally, the impact of microcytosis on platelet count accuracy was evaluated. Methods: This study was carried out between February and December 2014 at the Haematology Laboratory of the Sultan Qaboos University Hospital in Muscat, Oman. Blood samples were collected and analysed from 189 patients with thrombocytopaenia and MCV values of <76 femtolitres. Platelet counts were tested using both optical and impedance methods. Stained peripheral blood films for each sample were then reviewed as a reference method to confirm platelet counts. Results: The platelet counts estimated by the impedance method were on average 30% higher than those estimated by the optical method (P <0.001. The estimated intraclass correlation coefficient was 0.52 (95% confidence interval: 0.41–0.62, indicating moderate reliability between the methods. The degree of agreement between methods ranged from -85.5 to 24.3 with an estimated bias of -30, suggesting that these methods generate different platelet results. Conclusion: The impedance method significantly overestimated platelet counts in microcytic and thrombocytopaenic blood samples. Further attention is therefore needed to improve the accuracy of platelet counts, particularly for patients with conditions associated with microcytosis.

  20. Card counting in continuous time

    OpenAIRE

    Andersson, Patrik

    2012-01-01

    We consider the problem of finding an optimal betting strategy for a house-banked casino card game that is played for several coups before reshuffling. The sampling without replacement makes it possible to take advantage of the changes in the expected value as the deck is depleted, making large bets when the game is advantageous. Using such a strategy, which is easy to implement, is known as card counting. We consider the case of a large number of decks, making an approximat...

  1. Correlation of routine haematological parameters between normal maternal blood and the cord blood of healthy newborns in selected hospitals of karachi

    International Nuclear Information System (INIS)

    Qaiser, D.H.; Ghori, G.M.; Sandila, M.P.; Omair, A.

    2013-01-01

    Objective: To determine any significant correlation between the routine haematological parameters of maternal blood and umbilical cord blood of their respective newborns. Study Design: Cross sectional study. Place and Duration of Study: The study was conducted at four public and private hospitals of Karachi including Sindh Government Qatar Hospital, Sindh Government Hospital, Liaquatabad, Ziauddin University Hospital and Chinniot Maternity and Child Hospital, respectively from July 2006 to April 2008. Methodology: Three milliliters venous blood was collected in EDTA containing tube for complete blood count of mothers before delivery. Five milliliters cord blood was collected from the umbilical cord of the babies immediately after delivery by clamping and cutting the babies' end of the cord. For haematological parameters a standard coultergram was done including haemoglobin, RBCs count, haematocrit (HCT), mean corpuscular volume (MCV), mean corpuscular haemoglobin (MCH), mean corpuscular haemoglobin concentration (MCHC), white blood cell count, differential leukocyte count and platelet count. Pearson's correlation co-efficient was used to determine an association between the maternal and cord blood parameters. Results: A total of 404 maternal and umbilical cord blood samples were analyzed. All the blood parameters including haemoglobin, RBCs count, HCT, MCV, MCH, white blood cell count, differential leukocyte count and platelet count were found to be high in cord blood as compared to the maternal blood, but they showed a very weak to negligible correlation. Mean Corpuscular Haemoglobin Concentration (MCHC), showed a moderate correlation. Conclusion: Routine haematological parameters of newborns are independent of maternal routine haematological parameters. (author)

  2. Reproducibility of Manual Platelet Estimation Following Automated Low Platelet Counts

    Directory of Open Access Journals (Sweden)

    Zainab S Al-Hosni

    2016-11-01

    Full Text Available Objectives: Manual platelet estimation is one of the methods used when automated platelet estimates are very low. However, the reproducibility of manual platelet estimation has not been adequately studied. We sought to assess the reproducibility of manual platelet estimation following automated low platelet counts and to evaluate the impact of the level of experience of the person counting on the reproducibility of manual platelet estimates. Methods: In this cross-sectional study, peripheral blood films of patients with platelet counts less than 100 × 109/L were retrieved and given to four raters to perform manual platelet estimation independently using a predefined method (average of platelet counts in 10 fields using 100× objective multiplied by 20. Data were analyzed using intraclass correlation coefficient (ICC as a method of reproducibility assessment. Results: The ICC across the four raters was 0.840, indicating excellent agreement. The median difference of the two most experienced raters was 0 (range: -64 to 78. The level of platelet estimate by the least-experienced rater predicted the disagreement (p = 0.037. When assessing the difference between pairs of raters, there was no significant difference in the ICC (p = 0.420. Conclusions: The agreement between different raters using manual platelet estimation was excellent. Further confirmation is necessary, with a prospective study using a gold standard method of platelet counts.

  3. Monitoring Milk Somatic Cell Counts

    Directory of Open Access Journals (Sweden)

    Gheorghe Şteţca

    2014-11-01

    Full Text Available The presence of somatic cells in milk is a widely disputed issue in milk production sector. The somatic cell counts in raw milk are a marker for the specific cow diseases such as mastitis or swollen udder. The high level of somatic cells causes physical and chemical changes to milk composition and nutritional value, and as well to milk products. Also, the mastitic milk is not proper for human consumption due to its contribution to spreading of certain diseases and food poisoning. According to these effects, EU Regulations established the maximum threshold of admitted somatic cells in raw milk to 400000 cells / mL starting with 2014. The purpose of this study was carried out in order to examine the raw milk samples provided from small farms, industrial type farms and milk processing units. There are several ways to count somatic cells in milk but the reference accepted method is the microscopic method described by the SR EN ISO 13366-1/2008. Generally samples registered values in accordance with the admissible limit. By periodical monitoring of the somatic cell count, certain technological process issues are being avoided and consumer’s health ensured.

  4. Eosinophil count, allergies, and rejection in pediatric heart transplant recipients.

    Science.gov (United States)

    Arbon, Kate S; Albers, Erin; Kemna, Mariska; Law, Sabrina; Law, Yuk

    2015-08-01

    Allograft rejection and long-term immunosuppression remain significant challenges in pediatric heart transplantation. Pediatric recipients are known to have fewer rejection episodes and to develop more allergic conditions than adults. A T-helper 2 cell dominant phenotype, manifested clinically by allergies and an elevated eosinophil count, may be associated with immunologic quiescence in transplant recipients. This study assessed whether the longitudinal eosinophil count and an allergic phenotype were associated with freedom from rejection. This single-center, longitudinal, observational study included 86 heart transplant patients monitored from 1994 to 2011. Post-transplant biannual complete blood counts, allergic conditions, and clinical characteristics related to rejection risk were examined. At least 1 episode of acute cellular rejection (ACR) occurred in 38 patients (44%), antibody-mediated rejection (AMR) occurred in 11 (13%), and 49 patients (57%) were diagnosed with an allergic condition. Patients with ACR or AMR had a lower eosinophil count compared with non-rejectors (p = 0.011 and p = 0.022, respectively). In the multivariable regression analysis, the presence of panel reactive antibodies to human leukocyte antigen I (p = 0.014) and the median eosinophil count (p = 0.011) were the only independent covariates associated with AMR. Eosinophil count (p = 0.010) and female sex (p = 0.009) were independent risk factors for ACR. Allergic conditions or young age at transplant were not protective from rejection. This study demonstrates a novel association between a high eosinophil count and freedom from rejection. Identifying a biomarker for low rejection risk may allow a reduction in immunosuppression. Further investigation into the role of the T-helper 2 cell phenotype and eosinophils in rejection quiescence is warranted. Copyright © 2015 International Society for Heart and Lung Transplantation. Published by Elsevier Inc. All rights reserved.

  5. Allogeneic Peripheral Blood Stem Cell Harvest

    Indian Academy of Sciences (India)

    First page Back Continue Last page Overview Graphics. Allogeneic Peripheral Blood Stem Cell Harvest. Mobilization protocol. G-CSF 10 mcg/Kg / day for 5 days. Pheresis. Cobe Spectra; Haemonetics mcs+. Enumeration. CD34 counts; Cfu-GM assays.

  6. ESTUDO DO LEUCOGRAMA COMO MONITOR DO 2-1 FOSFATO DISSÓDICO DE BETAMETASONA DO FOSFATO DISSÓDICO/ACETATO DE DEXAMETASONA, EM CÃES QUE RECEBERAM TRANSPLANTES COM CÓRNEAS DE SUÍNOS WHITE BLOOD COUNT AS A 2-1 BETAMETHASONE DISSODIC FOSFHATE AND DEXAMETHASONE DISSODIC FOSPHATE/ACETATE MONITOR IN SWINE CORNEA TRANSPLANTED DOGS

    Directory of Open Access Journals (Sweden)

    Larissa Franco de Araújo

    2007-09-01

    . Each animal had swine cornea implanted into the left eye. The swine cornea was obtained at Casa de Banha Caçula, a slaughterhouse, and conserved in a humid chamber during a maximum 6 hour period. Each animal received 4 mg dissodic fosphate/acetate dexamethasone IM and was instilled one drop of gentamycin sulphate/betametbasone dissodic fosphate, maintaining ocular medication 4 times/day and intramuscular medication once a week until euthanasia. Each animal had blood samples collected on day 0, before surgery, and on day 14 and 28 to analyse white blood count as a monitor of corticosteroids, imunocellular supressor drugs. From ten blood samples collected on day 0, 80% didn’t present any alterations, 10% presented leukocytosis with neutrophilia and 10% weren’t submitted to analysis. Due to the fact that three animals had been euthanized between days 14 and 21, these samples (40%, were analyzed and compared with these collected on day 0. Five animals (50% had their samples examined on day 28. On both days 14 and 28, there were 100% neutrophilia, 100% eosinophilia and 44.4% lymphocytopenia, indicating imunocellular supression.

    KEY-WORDS: Corticosteroids; xenotransplants; cornea; canine; swine.

  7. Assessment of the background count to measure the left ventricular ejection fraction with a nuclear stethoscope

    International Nuclear Information System (INIS)

    Doi, Mayumi; Hiroe, Michiaki; Marumo, Fumiaki; Itoh, Haruki; Taniguchi, Koichi.

    1993-01-01

    The nuclear stethoscope is a newly developed device for monitoring left ventricular ejection fraction (EF) with a pair of cadmium telluride detector for both left ventricular count (first channel) and background count (second channel). Although it is useful for evaluating the cardiac function during exercise, the methodology of the calculation for distinguishing the net ventricular blood count from the background count has not been established yet. In order to establish a reasonable method to calculate EF, we measured EF using a nuclear stethoscope and conventional gated blood pool scintigraphy in 20 healthy volunteers. All subjects underwent two supine ergometer exercise tests consisting of the 3 stages for the nuclear stethoscope and blood pool scintigraphy. The EF was determined with the following three methods for the nuclear stethoscope: 1) Cut-off level was fixed at 70% of first channel, 2) Cut-off level at 75%, and 3) Cut-off level was determined by the background count obtained from second channel. There was a poor relationship between the EFs obtained from gated blood scintigraphy and the EFs from the nuclear stethoscope calculated by any of these methods. Regarding the EF calculated using the background count, however, the delta values of EF between rest and any of the 3 stages during exercise correlated closely to those EF from blood scintigraphy. When we apply the EF-at-rest value obtained from blood pool scintigraphy to analysis with the nuclear stethoscope, the EFs of 3 stages indicated good correlation (Stage I r=0.91, Stage II r=0.82, Stage III r=0.69). These results suggest that detecting the background count is useful in order to measure the left ventricular EF with the nuclear stethoscope. Since the absolute value of EF does not necessarily correlate to that from blood pool scintigraphy in this mehod, it is recommended to evaluate only the changing values of the EF. (author)

  8. Assessment of the background count to measure the left ventricular ejection fraction with a nuclear stethoscope

    Energy Technology Data Exchange (ETDEWEB)

    Doi, Mayumi; Hiroe, Michiaki; Marumo, Fumiaki (Tokyo Medical and Dental Univ. (Japan). School of Medicine); Itoh, Haruki; Taniguchi, Koichi

    1993-06-01

    The nuclear stethoscope is a newly developed device for monitoring left ventricular ejection fraction (EF) with a pair of cadmium telluride detector for both left ventricular count (first channel) and background count (second channel). Although it is useful for evaluating the cardiac function during exercise, the methodology of the calculation for distinguishing the net ventricular blood count from the background count has not been established yet. In order to establish a reasonable method to calculate EF, we measured EF using a nuclear stethoscope and conventional gated blood pool scintigraphy in 20 healthy volunteers. All subjects underwent two supine ergometer exercise tests consisting of the 3 stages for the nuclear stethoscope and blood pool scintigraphy. The EF was determined with the following three methods for the nuclear stethoscope: (1) Cut-off level was fixed at 70% of first channel, (2) Cut-off level at 75%, and (3) Cut-off level was determined by the background count obtained from second channel. There was a poor relationship between the EFs obtained from gated blood scintigraphy and the EFs from the nuclear stethoscope calculated by any of these methods. Regarding the EF calculated using the background count, however, the delta values of EF between rest and any of the 3 stages during exercise correlated closely to those EF from blood scintigraphy. When we apply the EF-at-rest value obtained from blood pool scintigraphy to analysis with the nuclear stethoscope, the EFs of 3 stages indicated good correlation (Stage I r=0.91, Stage II r=0.82, Stage III r=0.69). These results suggest that detecting the background count is useful in order to measure the left ventricular EF with the nuclear stethoscope. Since the absolute value of EF does not necessarily correlate to that from blood pool scintigraphy in this mehod, it is recommended to evaluate only the changing values of the EF. (author).

  9. Psychosocial factors and T lymphocyte counts in Brazilian peacekeepers.

    Science.gov (United States)

    Silva, Angela M Monteiro da; Speranza, Francisco A B; Ishii, Solange Kiyoko; Hirata, Raphael; Mattos-Guaraldi, Ana Luíza; Milagres, Lucimar Gonçalves

    2015-02-01

    To investigate the associations between psychosocial factors and peripheral blood CD4 and CD8 T lymphocyte numbers in Brazilian peacekeepers. Venous blood was collected from 759 peacekeepers who had just returned from a peace mission in Haiti. Among the 759 soldiers, 642 individuals completed the psychosocial measures. CD4 and CD8 T lymphocyte counts were measured by flow cytometry using a commercially available kit. Psychosocial factors, including military peace force stressors, clinical stress, anxiety and depression, were recorded. As a reference for T lymphocyte numbers, we measured T lymphocyte counts in 75 blood donors from the Instituto de Biologia do Exército, Rio de Janeiro. The median numbers of CD4 and CD8 T lymphocytes in the blood donors were 819 cells/µl and 496 cells/µl, respectively, with a CD4:CD8 ratio of 1.6. Significantly (p<0.05) lower CD4 T cell counts (759 cells/µl) were recorded for peacekeepers, with similar CD8 levels (548 cells/µl) and smaller CD4:CD8 ratios (1.3, p<0.001) compared to blood donors. These differences were due to a group of 14 military personnel with CD4 and CD8 medians of 308 and 266 cells/µl, respectively. Only one (7.1%) of these 14 individuals was diagnosed with clinical stress compared with 13.5% of the individuals with normal levels of CD4 T lymphocytes. One individual out of 628 (0.16%) had a Lipp's Stress Symptom Inventory score of 3, indicating near exhaustion. The prevalence of psychological disorders was low and there were no associations with CD4 or CD8 T cell numbers.

  10. Repeatability of differential goat bulk milk culture and associations with somatic cell count, total bacterial count, and standard plate count

    NARCIS (Netherlands)

    Koop, G.; Dik, N.; Nielen, M.; Lipman, L.J.A.

    2010-01-01

    The aims of this study were to assess how different bacterial groups in bulk milk are related to bulk milk somatic cell count (SCC), bulk milk total bacterial count (TBC), and bulk milk standard plate count (SPC) and to measure the repeatability of bulk milk culturing. On 53 Dutch dairy goat farms,

  11. Nearest neighbors by neighborhood counting.

    Science.gov (United States)

    Wang, Hui

    2006-06-01

    Finding nearest neighbors is a general idea that underlies many artificial intelligence tasks, including machine learning, data mining, natural language understanding, and information retrieval. This idea is explicitly used in the k-nearest neighbors algorithm (kNN), a popular classification method. In this paper, this idea is adopted in the development of a general methodology, neighborhood counting, for devising similarity functions. We turn our focus from neighbors to neighborhoods, a region in the data space covering the data point in question. To measure the similarity between two data points, we consider all neighborhoods that cover both data points. We propose to use the number of such neighborhoods as a measure of similarity. Neighborhood can be defined for different types of data in different ways. Here, we consider one definition of neighborhood for multivariate data and derive a formula for such similarity, called neighborhood counting measure or NCM. NCM was tested experimentally in the framework of kNN. Experiments show that NCM is generally comparable to VDM and its variants, the state-of-the-art distance functions for multivariate data, and, at the same time, is consistently better for relatively large k values. Additionally, NCM consistently outperforms HEOM (a mixture of Euclidean and Hamming distances), the "standard" and most widely used distance function for multivariate data. NCM has a computational complexity in the same order as the standard Euclidean distance function and NCM is task independent and works for numerical and categorical data in a conceptually uniform way. The neighborhood counting methodology is proven sound for multivariate data experimentally. We hope it will work for other types of data.

  12. CalCOFI Egg Counts Positive Tows

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Fish egg counts and standardized counts for eggs captured in CalCOFI icthyoplankton nets (primarily vertical [Calvet or Pairovet], oblique [bongo or ring nets], and...

  13. CalCOFI Larvae Counts Positive Tows

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Fish larvae counts and standardized counts for eggs captured in CalCOFI icthyoplankton nets (primarily vertical [Calvet or Pairovet], oblique [bongo or ring nets],...

  14. Alaska Steller Sea Lion Pup Count Database

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — This database contains counts of Steller sea lion pups on rookeries in Alaska made between 1961 and 2015. Pup counts are conducted in late June-July. Pups are...

  15. SPERM COUNT DISTRIBUTIONS IN FERTILE MEN

    Science.gov (United States)

    Sperm concentration and count are often used as indicators of environmental impacts on male reproductive health. Existing clinical databases may be biased towards subfertile men with low sperm counts and less is known about expected sperm count distributions in cohorts of fertil...

  16. Platelet counting using the Coulter electronic counter.

    Science.gov (United States)

    Eggleton, M J; Sharp, A A

    1963-03-01

    A method for counting platelets in dilutions of platelet-rich plasm using the Coulter electronic counter is described.(1) The results obtained show that such platelet counts are at least as accurate as the best methods of visual counting. The various technical difficulties encountered are discussed.

  17. Count-doubling time safety circuit

    International Nuclear Information System (INIS)

    Keefe, D.J.; McDowell, W.P.; Rusch, G.K.

    1981-01-01

    There is provided a nuclear reactor count-factor-increase time monitoring circuit which includes a pulse-type neutron detector, and means for counting the number of detected pulses during specific time periods. Counts are compared and the comparison is utilized to develop a reactor scram signal, if necessary

  18. Count-doubling time safety circuit

    Science.gov (United States)

    Rusch, Gordon K.; Keefe, Donald J.; McDowell, William P.

    1981-01-01

    There is provided a nuclear reactor count-factor-increase time monitoring circuit which includes a pulse-type neutron detector, and means for counting the number of detected pulses during specific time periods. Counts are compared and the comparison is utilized to develop a reactor scram signal, if necessary.

  19. DC KIDS COUNT e-Databook Indicators

    Science.gov (United States)

    DC Action for Children, 2012

    2012-01-01

    This report presents indicators that are included in DC Action for Children's 2012 KIDS COUNT e-databook, their definitions and sources and the rationale for their selection. The indicators for DC KIDS COUNT represent a mix of traditional KIDS COUNT indicators of child well-being, such as the number of children living in poverty, and indicators of…

  20. How much do women count if they not counted?

    Directory of Open Access Journals (Sweden)

    Federica Taddia

    2006-01-01

    Full Text Available The condition of women throughout the world is marked by countless injustices and violations of the most fundamental rights established by the Universal Declaration of human rights and every culture is potentially prone to commit discrimination against women in various forms. Women are worse fed, more exposed to physical violence, more exposed to diseases and less educated; they have less access to, or are excluded from, vocational training paths; they are the most vulnerable among prisoners of conscience, refugees and immigrants and the least considered within ethnic minorities; from their very childhood, women are humiliated, undernourished, sold, raped and killed; their work is generally less paid compared to men’s work and in some countries they are victims of forced marriages. Such condition is the result of old traditions that implicit gender-differentiated education has long promoted through cultural models based on theories, practices and policies marked by discrimination and structured differentially for men and women. Within these cultural models, the basic educational institutions have played and still play a major role in perpetuating such traditions. Nevertheless, if we want to overcome inequalities and provide women with empowerment, we have to start right from the educational institutions and in particular from school, through the adoption of an intercultural approach to education: an approach based on active pedagogy and on methods of analysis, exchange and enhancement typical of socio-educational animation. The intercultural approach to education is attentive to promote the realisation of each individual and the dignity and right of everyone to express himself/herself in his/her own way. Such an approach will give women the opportunity to become actual agents of collective change and to get the strength and wellbeing necessary to count and be counted as human beings entitled to freedom and equality, and to have access to all

  1. Donating Blood

    Science.gov (United States)

    ... The medical history includes questions that help blood bank staff decide if a person is healthy enough to donate blood. They'll ... Food and Drug Administration (FDA) regulates U.S. blood banks. All blood ... operating. Sometimes people who donate blood notice a few minor side ...

  2. Serum inhibin-b in fertile men is strongly correlated with low but not high sperm counts: a coordinated study of 1,797 European and US men

    DEFF Research Database (Denmark)

    Jørgensen, Niels; Liu, Fan; Andersson, Anna-Maria

    2010-01-01

    To describe associations between serum inhibin-b and sperm counts, adjusted for effect of time of blood sampling, in larger cohorts than have been previously reported.......To describe associations between serum inhibin-b and sperm counts, adjusted for effect of time of blood sampling, in larger cohorts than have been previously reported....

  3. What's Blood?

    Science.gov (United States)

    ... Body Make Blood? It's not made in a kitchen, but blood has ingredients, just like a recipe. ... these ingredients together and you have blood — an essential part of the circulatory system. Thanks to your ...

  4. Blood typing

    Science.gov (United States)

    ... detect these minor antigens. It is done before transfusions, except in emergency situations. Alternative Names Cross matching; Rh typing; ABO blood typing; Blood group; Anemia - immune hemolytic blood type; ...

  5. Blood smear

    Science.gov (United States)

    ... smear URL of this page: //medlineplus.gov/ency/article/003665.htm Blood smear To use the sharing features on this ... view of cellular parasites Malaria, photomicrograph of cellular parasites Red blood cells, sickle cells Red blood cells, sickle and ...

  6. Radon counting statistics - a Monte Carlo investigation

    International Nuclear Information System (INIS)

    Scott, A.G.

    1996-01-01

    Radioactive decay is a Poisson process, and so the Coefficient of Variation (COV) of open-quotes nclose quotes counts of a single nuclide is usually estimated as 1/√n. This is only true if the count duration is much shorter than the half-life of the nuclide. At longer count durations, the COV is smaller than the Poisson estimate. Most radon measurement methods count the alpha decays of 222 Rn, plus the progeny 218 Po and 214 Po, and estimate the 222 Rn activity from the sum of the counts. At long count durations, the chain decay of these nuclides means that every 222 Rn decay must be followed by two other alpha decays. The total number of decays is open-quotes 3Nclose quotes, where N is the number of radon decays, and the true COV of the radon concentration estimate is 1/√(N), √3 larger than the Poisson total count estimate of 1/√3N. Most count periods are comparable to the half lives of the progeny, so the relationship between COV and count time is complex. A Monte-Carlo estimate of the ratio of true COV to Poisson estimate was carried out for a range of count periods from 1 min to 16 h and three common radon measurement methods: liquid scintillation, scintillation cell, and electrostatic precipitation of progeny. The Poisson approximation underestimates COV by less than 20% for count durations of less than 60 min

  7. Discrete calculus methods for counting

    CERN Document Server

    Mariconda, Carlo

    2016-01-01

    This book provides an introduction to combinatorics, finite calculus, formal series, recurrences, and approximations of sums. Readers will find not only coverage of the basic elements of the subjects but also deep insights into a range of less common topics rarely considered within a single book, such as counting with occupancy constraints, a clear distinction between algebraic and analytical properties of formal power series, an introduction to discrete dynamical systems with a thorough description of Sarkovskii’s theorem, symbolic calculus, and a complete description of the Euler-Maclaurin formulas and their applications. Although several books touch on one or more of these aspects, precious few cover all of them. The authors, both pure mathematicians, have attempted to develop methods that will allow the student to formulate a given problem in a precise mathematical framework. The aim is to equip readers with a sound strategy for classifying and solving problems by pursuing a mathematically rigorous yet ...

  8. Counting paths with Schur transitions

    Energy Technology Data Exchange (ETDEWEB)

    Díaz, Pablo [Department of Physics and Astronomy, University of Lethbridge, Lethbridge, Alberta, T1K 3M4 (Canada); Kemp, Garreth [Department of Physics, University of Johannesburg, P.O. Box 524, Auckland Park 2006 (South Africa); Véliz-Osorio, Alvaro, E-mail: aveliz@gmail.com [Mandelstam Institute for Theoretical Physics, University of the Witwatersrand, WITS 2050, Johannesburg (South Africa); School of Physics and Astronomy, Queen Mary, University of London, Mile End Road, London E1 4NS (United Kingdom)

    2016-10-15

    In this work we explore the structure of the branching graph of the unitary group using Schur transitions. We find that these transitions suggest a new combinatorial expression for counting paths in the branching graph. This formula, which is valid for any rank of the unitary group, reproduces known asymptotic results. We proceed to establish the general validity of this expression by a formal proof. The form of this equation strongly hints towards a quantum generalization. Thus, we introduce a notion of quantum relative dimension and subject it to the appropriate consistency tests. This new quantity finds its natural environment in the context of RCFTs and fractional statistics; where the already established notion of quantum dimension has proven to be of great physical importance.

  9. Mass counting of radioactivity samples

    International Nuclear Information System (INIS)

    Oesterlin, D.L.; Obrycki, R.F.

    1977-01-01

    A method and apparatus for concurrently counting a plurality of radioactive samples is claimed. The position sensitive circuitry of a scintillation camera is employed to sort electrical pulses resulting from scintillations according to the geometrical locations of scintillations causing those pulses. A scintillation means, in the form of a scintillating crystal material or a liquid scintillator, is positioned proximate to an array of radioactive samples. Improvement in the accuracy of pulse classification may be obtained by employing collimating means. If a plurality of scintillation crystals are employed to measure the iodine-125 content of samples, a method and means are provided for correcting for variations in crystal light transmission properties, sample volume, and sample container radiation absorption. 2 claims, 7 drawing figures

  10. Interpretation of serum antibody response to Anoplocephala perfoliata in relation to parasite burden and faecal egg count

    DEFF Research Database (Denmark)

    Kjaer, L.N.; Lungholt, M.M.; Nielsen, M.K.

    2007-01-01

    of development and gross pathological mucosal lesions were recorded and compared with serum antibody responses and faecal egg counts. Faecal egg counts were determined in samples from A. perfoliata infected horses using a semi-quantitative centrifugation/flotation technique. Blood samples collected at slaughter...

  11. Association of peripheral total and differential leukocyte counts with obesity-related complications in young adults.

    Science.gov (United States)

    Yoshimura, Aya; Ohnishi, Shunsuke; Orito, Chieko; Kawahara, Yukako; Takasaki, Hiroyo; Takeda, Hiroshi; Sakamoto, Naoya; Hashino, Satoshi

    2015-01-01

    Obesity has been demonstrated to be associated with elevated leukocytes in adults and children. This study assessed the associations between peripheral total and differential leukocyte counts and obesity-related complications in young adults. 12 obese (median age 21.5 (range 19-28) years, median BMI 35.7 (range 32.0-44.9) kg/m(2)) and 11 normal (median age 23 (range 18-27) years, median BMI 19.5 (range 18.1-21.7) kg/m(2)) adults were enrolled. Complete blood count and serum levels of liver enzymes, fasting blood glucose, insulin and lipids were measured, and the homeostasis model assessment of insulin resistance was calculated. Fat mass was calculated using a bioimpedance analysis device, and ultrasonography was performed to measure fat thickness and to detect fatty change of the liver. Total leukocyte and monocyte counts were significantly increased in obese young adults. Total leukocyte count was associated with liver enzyme levels, insulin resistance as well as visceral and subcutaneous fat thickness. Neutrophil count was associated with insulin resistance. Lymphocyte count was associated with serum liver enzymes, insulin resistance, and dyslipidemia. Monocyte count was associated with serum liver enzyme, insulin resistance, visceral and subcutaneous fat thickness, body fat mass, and percentage body fat. The results of this study suggest that chronic low-grade systemic inflammation is associated with obesity-related complications such as nonalcoholic fatty liver disease, insulin resistance, and dyslipidemia in young adults. © 2015 S. Karger GmbH, Freiburg.

  12. Counting Zero: Rethinking Feminist Epistemologies

    Directory of Open Access Journals (Sweden)

    Xin Liu

    2017-10-01

    Full Text Available This article concerns feminist engagements with epistemologies. Feminist epistemologies have revealed and challenged the exclusions and denigrations at work in knowledge production processes. And yet, the emphasis on the partiality of knowledge and the non-innocence of any subject position also cast doubt on the possibility of feminist political communities. In view of this, it has been argued that the very parameter of epistemology poses limitations for feminism, for it leads to either political paralysis or prescriptive politics that in fact undoes the political of politics. From a different perspective, decolonial feminists argue for radical epistemic disobedience and delinking the move beyond the confines of Western systems of knowledge and its extractive knowledge economy. Nevertheless, the oppositional logic informs both feminist epistemologies and its critiques, which I argue is symptomatic of the epistemic habits of academic feminism. This article ends with a preliminary reconsideration of the question of origin through the figure of zero. It asks whether it might be possible to conceive of feminist epistemologies as performing the task of counting zero – accounting for origin, wholeness, and universality – that takes into account specificities without forfeiting coalition and claims to knowledge.

  13. Heterogeneous counting on filter support media

    International Nuclear Information System (INIS)

    Long, E.; Kohler, V.; Kelly, M.J.

    1976-01-01

    Many investigators in the biomedical research area have used filter paper as the support for radioactive samples. This means that a heterogeneous counting of sample sometimes results. The count rate of a sample on a filter will be affected by positioning, degree of dryness, sample application procedure, the type of filter, and the type of cocktail used. Positioning of the filter (up or down) in the counting vial can cause a variation of 35% or more when counting tritiated samples on filter paper. Samples of varying degrees of dryness when added to the counting cocktail can cause nonreproducible counts if handled improperly. Count rates starting at 2400 CPM initially can become 10,000 CPM in 24 hours for 3 H-DNA (deoxyribonucleic acid) samples dried on standard cellulose acetate membrane filters. Data on cellulose nitrate filters show a similar trend. Sample application procedures in which the sample is applied to the filter in a small spot or on a large amount of the surface area can cause nonreproducible or very low counting rates. A tritiated DNA sample, when applied topically, gives a count rate of 4,000 CPM. When the sample is spread over the whole filter, 13,400 CPM are obtained with a much better coefficient of variation (5% versus 20%). Adding protein carrier (bovine serum albumin-BSA) to the sample to trap more of the tritiated DNA on the filter during the filtration process causes a serious beta absorption problem. Count rates which are one-fourth the count rate applied to the filter are obtained on calibrated runs. Many of the problems encountered can be alleviated by a proper choice of filter and the use of a liquid scintillation cocktail which dissolves the filter. Filter-Solv has been used to dissolve cellulose nitrate filters and filters which are a combination of cellulose nitrate and cellulose acetate. Count rates obtained for these dissolved samples are very reproducible and highly efficient

  14. Leveraging multiple datasets for deep leaf counting

    OpenAIRE

    Dobrescu, Andrei; Giuffrida, Mario Valerio; Tsaftaris, Sotirios A

    2017-01-01

    The number of leaves a plant has is one of the key traits (phenotypes) describing its development and growth. Here, we propose an automated, deep learning based approach for counting leaves in model rosette plants. While state-of-the-art results on leaf counting with deep learning methods have recently been reported, they obtain the count as a result of leaf segmentation and thus require per-leaf (instance) segmentation to train the models (a rather strong annotation). Instead, our method tre...

  15. Resonance ionization spectroscopy: Counting noble gas atoms

    International Nuclear Information System (INIS)

    Hurst, G.S.; Payne, M.G.; Chen, C.H.; Willis, R.D.; Lehmann, B.E.; Kramer, S.D.

    1981-01-01

    The purpose of this paper is to describe new work on the counting of noble gas atoms, using lasers for the selective ionization and detectors for counting individual particles (electrons or positive ions). When positive ions are counted, various kinds of mass analyzers (magnetic, quadrupole, or time-of-flight) can be incorporated to provide A selectivity. We show that a variety of interesting and important applications can be made with atom-counting techniques which are both atomic number (Z) and mass number (A) selective. (orig./FKS)

  16. 白细胞计数、C反应蛋白联合呼吸道病原体抗体检测在小儿肺炎的早期诊断价值%Value of white blood cell count, C-reactive protein combined with respiratory pathogen antibody in the early diagnosis of pneumonia in children

    Institute of Scientific and Technical Information of China (English)

    傅雅浓

    2017-01-01

    Objective To investigate the effects of procalcitonin(PCT),C-reactive protein(CRP)and white blood cell count(WBC)in children with different pathogenic infectious diseases diagnostic value.Methods 1300 cases of hospitalized pneumonia fromJanuary 2013 to January 2016in our hospital were selected,and the CRP,WBC,PCT and pathogens were examined and compared.Results The positive rate of CRP was 13.53%,among the 1 300 cases,the number of CRP positive was the highest among the 5 years old in the group,and there was no significant difference between the two groups.The levels of serum PCT,CRP and WBC in bacterial infection group were significantly higher than those in virus infection group,the level of CRP in mycoplasma pneumoniae infection group was significantly higher than that in virus infection group,the levels of PCT and WBC in patients with bacterial infection were significantly higher than those in Mycoplasma infection group,the difference was statistically significant(P 0.05ng/mL,CRP> 6mg/L and WBC>10×109/L were 91.07%and 90.78%respectively.The positive predictive value was 87.95%,negative predictive value of 90.78%,compared to CRP and WBC diagnosis of sensitivity,specificity were significantly increased.Conclusion When the clinical diagnosis of infection in children can be diagnosed,the first application of WBC for testing,to be initially screening,followed by CRP and pathogen detection of the disease to conduct a comprehensive assessment and identification.%目的 探讨血清降钙素原(procalcitonin,PCT)、C 反应蛋白(C-reactive protein,CRP)及白细胞计数(white blood cellcou nt,WBC)的测定在儿童不同病原感染性疾病中的诊断价值.方法 选取2013年1月~2016年1月慈溪市妇幼保健院收治的1 300 例住院肺炎患儿,对其CRP、WBC、PCT 及病原体进行检测并比较.结果 CRP 的阳性率为13.53%,1 300 例患儿中,CRP 阳性例数在5 岁组中,各类病原体感染组间表达差异无统计学意

  17. Whole-body counting 1990

    International Nuclear Information System (INIS)

    Strand, P.; Selnaes, T.D.

    1990-01-01

    In order to determine the doses from radiocesium in foods after the Chernobyl accident, four groups were chosen in 1987. Two groups, presumed to have a large consumption of food items with a high radiocesium content, were selected. These were Lapp reindeer breeders from central parts of Norway, and hunters a.o. from the municipality of Oeystre Slidre. Two other groups were randomly selected, one from the municipality of Sel, and one from Oslo. The persons in these two groups were presumed to have an average diet. The fall-out in Sel was fairly large (100 kBq/m 2 ), whereas in Oslo the fall-out level was low (2 kBq/m 2 ). The persons in each group were monitored once a year with whole-body counters, and in connection with these countings dietary surveys were preformed. In 1990 the Sel-group and the Lapps in central parts of Norway were followed. Average whole-body activity in each group is compared to earlier years's results, and an average yearly effective dose equivalent is computed. The Sel-group has an average whole-body activity of 2800 Bq for men, and 690 Bq for women. Compared to earlier years, there is a steady but slow decrease in whole-body activities. Yearly dose is calculated to 0.06 mSv for 1990. The Lapps in central parts of Norway have an average whole-body content of 23800 Bq for men and 13600 Bq for women. This results in an average yearly dose of 0.9 mSv for the individuals in the group. Compared to earlier years, the Lapp group show a decrease in whole-body contents since 1988. This decrease is larger among men than women. 5 refs., 8 figs., 6 tabs

  18. A novel method for detecting and counting overlapping tracks in SSNTD by image processing techniques

    International Nuclear Information System (INIS)

    Ab Azar, N.; Babakhani, A.; Broumandnia, A.; Sepanloo, K.

    2016-01-01

    Overlapping object detection and counting is a challenge in image processing. A new method for detecting and counting overlapping circles is presented in this paper. This method is based on pattern recognition and feature extraction using “neighborhood values“ in an object image by implementation of image processing techniques. The junction points are detected by assignment of a value for each pixel in an image. As is shown, the neighborhood values for junction points are larger than the values for other points. This distinction of neighborhood values is the main feature which can be utilized to identify the junction points and to count the overlapping tracks. This method can be used for recognizing and counting charged particle tracks, blood cells and also cancer cells. The method is called “Track Counting based on Neighborhood Values” and is symbolized by “TCNV”. - Highlights: • A new method is introduced to recognize nuclear tracks by image processing. • The method is used to specify neighborhood pixels in junction points in overlapping tracks. • Enhanced method of counting overlapping tracks. • New counting system has linear behavior in counting tracks with density less than 300,000 tracks per cm"2. • In the new method, the overlap tracks can be recognized even to 10× tracks and more.

  19. Error in laboratory report data for platelet count assessment in patients suspicious for dengue: a note from observation

    Directory of Open Access Journals (Sweden)

    Somsri Wiwanitkit

    2016-08-01

    Full Text Available Dengue is a common tropical infection that is still a global health threat. An important laboratory parameter for the management of dengue is platelet count. Platelet count is an useful test for diagnosis and following up on dengue. However, errors in laboratory reports can occur. This study is a retrospective analysis on laboratory report data of complete blood count in cases with suspicious dengue in a medical center within 1 month period during the outbreak season on October, 2015. According to the studied period, there were 184 requests for complete blood count for cases suspected for dengue. From those 184 laboratory report records, errors can be seen in 12 reports (6.5%. This study demonstrates that there are considerable high rate of post-analytical errors in laboratory reports. Interestingly, the platelet count in those erroneous reports can be unreliable and ineffective or problematic when it is used for the management of dengue suspicious patients.

  20. System and method of liquid scintillation counting

    International Nuclear Information System (INIS)

    Rapkin, E.

    1977-01-01

    A method of liquid scintillation counting utilizing a combustion step to overcome quenching effects comprises novel features of automatic sequential introduction of samples into a combustion zone and automatic sequential collection and delivery of combustion products into a counting zone. 37 claims, 13 figures

  1. Is It Counting, or Is It Adding?

    Science.gov (United States)

    Eisenhardt, Sara; Fisher, Molly H.; Thomas, Jonathan; Schack, Edna O.; Tassell, Janet; Yoder, Margaret

    2014-01-01

    The Common Core State Standards for Mathematics (CCSSI 2010) expect second grade students to "fluently add and subtract within 20 using mental strategies" (2.OA.B.2). Most children begin with number word sequences and counting approximations and then develop greater skill with counting. But do all teachers really understand how this…

  2. Current status of liquid scintillation counting

    International Nuclear Information System (INIS)

    Klingler, G.W.

    1981-01-01

    Scintillation counting of alpha particles has been used since the turn of the century. The advent of pulse shape discrimination has made this method of detection accurate and reliable. The history, concepts and development of scintillation counting and pulse shape discrimination are discussed. A brief look at the ongoing work in the consolidation of components now used for pulse shape discrimination is included

  3. Lazy reference counting for the Microgrid

    NARCIS (Netherlands)

    Poss, R.; Grelck, C.; Herhut, S.; Scholz, S.-B.

    2012-01-01

    This papers revisits non-deferred reference counting, a common technique to ensure that potentially shared large heap objects can be reused safely when they are both input and output to computations. Traditionally, thread-safe reference counting exploit implicit memory-based communication of counter

  4. A Word Count of Modern Arabic Prose.

    Science.gov (United States)

    Landau, Jacob M.

    This book presents a word count of Arabic prose based on 60 twentieth-century Egyptian books. The text is divided into an alphabetical list and a word frequency list. This word count is intended as an aid in the: (1) writing of primers and the compilation of graded readers, (2) examination of the vocabulary selection of primers and readers…

  5. 2013 Kids Count in Colorado! Community Matters

    Science.gov (United States)

    Colorado Children's Campaign, 2013

    2013-01-01

    "Kids Count in Colorado!" is an annual publication of the Children's Campaign, providing state and county level data on child well-being factors including child health, education, and economic status. Since its first release 20 years ago, "Kids Count in Colorado!" has become the most trusted source for data and information on…

  6. Blood transfusions

    Science.gov (United States)

    ... this page: //medlineplus.gov/ency/patientinstructions/000431.htm Blood transfusions To use the sharing features on this page, ... There are many reasons you may need a blood transfusion: After knee or hip replacement surgery, or other ...

  7. Blood Types

    Science.gov (United States)

    ... positive or Rh-negative blood may be given to Rh-positive patients. The rules for plasma are the reverse: ... ethnic and racial groups have different frequency of the main blood types in their populations. Approximately ...

  8. Blood Conservation.

    Science.gov (United States)

    Martin, Jeremiah T; Ferraris, Victor A

    2015-01-01

    Patient blood management requires multi-modality and multidisciplinary collaboration to identify patients who are at increased risk of requiring blood transfusion and therefore decrease exposure to blood products. Transfusion is associated with poor postoperative outcomes, and guidelines exist to minimize transfusion requirements. This review highlights recent studies and efforts to apply patient blood management across disease processes and health care systems. Copyright © 2015 Elsevier Inc. All rights reserved.

  9. Validation of an automated colony counting system for group A Streptococcus.

    Science.gov (United States)

    Frost, H R; Tsoi, S K; Baker, C A; Laho, D; Sanderson-Smith, M L; Steer, A C; Smeesters, P R

    2016-02-08

    The practice of counting bacterial colony forming units on agar plates has long been used as a method to estimate the concentration of live bacteria in culture. However, due to the laborious and potentially error prone nature of this measurement technique, an alternative method is desirable. Recent technologic advancements have facilitated the development of automated colony counting systems, which reduce errors introduced during the manual counting process and recording of information. An additional benefit is the significant reduction in time taken to analyse colony counting data. Whilst automated counting procedures have been validated for a number of microorganisms, the process has not been successful for all bacteria due to the requirement for a relatively high contrast between bacterial colonies and growth medium. The purpose of this study was to validate an automated counting system for use with group A Streptococcus (GAS). Twenty-one different GAS strains, representative of major emm-types, were selected for assessment. In order to introduce the required contrast for automated counting, 2,3,5-triphenyl-2H-tetrazolium chloride (TTC) dye was added to Todd-Hewitt broth with yeast extract (THY) agar. Growth on THY agar with TTC was compared with growth on blood agar and THY agar to ensure the dye was not detrimental to bacterial growth. Automated colony counts using a ProtoCOL 3 instrument were compared with manual counting to confirm accuracy over the stages of the growth cycle (latent, mid-log and stationary phases) and in a number of different assays. The average percentage differences between plating and counting methods were analysed using the Bland-Altman method. A percentage difference of ±10 % was determined as the cut-off for a critical difference between plating and counting methods. All strains measured had an average difference of less than 10 % when plated on THY agar with TTC. This consistency was also observed over all phases of the growth

  10. What is the value of routinely testing full blood count, electrolytes and urea, and pulmonary function tests before elective surgery in patients with no apparent clinical indication and in subgroups of patients with common comorbidities: a systematic review of the clinical and cost-effective literature.

    Science.gov (United States)

    Czoski-Murray, C; Lloyd Jones, M; McCabe, C; Claxton, K; Oluboyede, Y; Roberts, J; Nicholl, J P; Rees, A; Reilly, C S; Young, D; Fleming, T

    2012-12-01

    The evidence base which supported the National Institute for Health and Clinical Excellence (NICE) published Clinical Guideline 3 was limited and 50% was graded as amber. However, the use of tests as part of pre-operative work-up remains a low-cost but high-volume activity within the NHS, with substantial resource implications. The objective of this study was to identify, evaluate and synthesise the published evidence on the clinical effectiveness and cost-effectiveness of the routine use of three tests, full blood counts (FBCs), urea and electrolytes tests (U&Es) and pulmonary function tests, in the pre-operative work-up of otherwise healthy patients undergoing minor or intermediate surgery in the NHS. The aims of this study were to estimate the clinical effectiveness and cost-effectiveness of routine pre-operative testing of FBC, electrolytes and renal function and pulmonary function in adult patients classified as American Society of Anaesthesiologists (ASA) grades 1 and 2 undergoing elective minor (grade 1) or intermediate (grade 2) surgical procedures; to compare NICE recommendations with current practice; to evaluate the cost-effectiveness of mandating or withdrawing each of these tests in this patient group; and to identify the expected value of information and whether or not it has value to the NHS in commissioning further primary research into the use of these tests in this group of patients. The following electronic bibliographic databases were searched: (1) BIOSIS; (2) Cumulative Index to Nursing and Allied Health Literature; (3) Cochrane Database of Systematic Reviews; (4) Cochrane Central Register of Controlled Trials; (5) EMBASE; (6) MEDLINE; (7) MEDLINE In-Process & Other Non-Indexed Citations; (8) NHS Database of Abstracts of Reviews of Effects; (9) NBS Health Technology Assessment Database; and (10) Science Citation Index. To identify grey and unpublished literature, the Cochrane Register of Controlled Trials, National Research Register Archive

  11. Standardization of {sup 241}Am by digital coincidence counting, liquid scintillation counting and defined solid angle counting

    Energy Technology Data Exchange (ETDEWEB)

    Balpardo, C., E-mail: balpardo@cae.cnea.gov.a [Laboratorio de Metrologia de Radioisotopos, CNEA, Buenos Aires (Argentina); Capoulat, M.E.; Rodrigues, D.; Arenillas, P. [Laboratorio de Metrologia de Radioisotopos, CNEA, Buenos Aires (Argentina)

    2010-07-15

    The nuclide {sup 241}Am decays by alpha emission to {sup 237}Np. Most of the decays (84.6%) populate the excited level of {sup 237}Np with energy of 59.54 keV. Digital coincidence counting was applied to standardize a solution of {sup 241}Am by alpha-gamma coincidence counting with efficiency extrapolation. Electronic discrimination was implemented with a pressurized proportional counter and the results were compared with two other independent techniques: Liquid scintillation counting using the logical sum of double coincidences in a TDCR array and defined solid angle counting taking into account activity inhomogeneity in the active deposit. The results show consistency between the three methods within a limit of a 0.3%. An ampoule of this solution will be sent to the International Reference System (SIR) during 2009. Uncertainties were analysed and compared in detail for the three applied methods.

  12. An Adaptive Smoother for Counting Measurements

    International Nuclear Information System (INIS)

    Kondrasovs Vladimir; Coulon Romain; Normand Stephane

    2013-06-01

    Counting measurements associated with nuclear instruments are tricky to carry out due to the stochastic process of the radioactivity. Indeed events counting have to be processed and filtered in order to display a stable count rate value and to allow variations monitoring in the measured activity. Smoothers (as the moving average) are adjusted by a time constant defined as a compromise between stability and response time. A new approach has been developed and consists in improving the response time while maintaining count rate stability. It uses the combination of a smoother together with a detection filter. A memory of counting data is processed to calculate several count rate estimates using several integration times. These estimates are then sorted into the memory from short to long integration times. A measurement position, in terms of integration time, is then chosen into this memory after a detection test. An inhomogeneity into the Poisson counting process is detected by comparison between current position estimate and the other estimates contained into the memory in respect with the associated statistical variance calculated with homogeneous assumption. The measurement position (historical time) and the ability to forget an obsolete data or to keep in memory a useful data are managed using the detection test result. The proposed smoother is then an adaptive and a learning algorithm allowing an optimization of the response time while maintaining measurement counting stability and converging efficiently to the best counting estimate after an effective change in activity. This algorithm has also the specificity to be low recursive and thus easily embedded into DSP electronics based on FPGA or micro-controllers meeting 'real life' time requirements. (authors)

  13. Long term observation on absolute lymphocyte counts in the adult health study sample, Hiroshima and Nagasaki

    International Nuclear Information System (INIS)

    Oesterle, S.N.; Norman, J.E. Jr.

    1980-01-01

    Total peripheral blood lymphocytes were evaluated by age and exposure status in the Adult Health Study population during three examination cycles between 1958 and 1972. No radiation effect was observed, but a significant drop in the absolute lymphocyte counts of those aged 70 years and over and a corresponding maximum for persons aged 50 - 59 was observed. (author)

  14. The effect of volume and quenching on estimation of counting efficiencies in liquid scintillation counting

    International Nuclear Information System (INIS)

    Knoche, H.W.; Parkhurst, A.M.; Tam, S.W.

    1979-01-01

    The effect of volume on the liquid scintillation counting performance of 14 C-samples has been investigated. A decrease in counting efficiency was observed for samples with volumes below about 6 ml and those above about 18 ml when unquenched samples were assayed. Two quench-correction methods, sample channels ratio and external standard channels ratio, and three different liquid scintillation counters, were used in an investigation to determine the magnitude of the error in predicting counting efficiencies when small volume samples (2 ml) with different levels of quenching were assayed. The 2 ml samples exhibited slightly greater standard deviations of the difference between predicted and determined counting efficiencies than did 15 ml samples. Nevertheless, the magnitude of the errors indicate that if the sample channels ratio method of quench correction is employed, 2 ml samples may be counted in conventional counting vials with little loss in counting precision. (author)

  15. Cord Blood

    Directory of Open Access Journals (Sweden)

    Saeed Abroun

    2014-05-01

    Full Text Available   Stem cells are naïve or master cells. This means they can transform into special 200 cell types as needed by body, and each of these cells has just one function. Stem cells are found in many parts of the human body, although some sources have richer concentrations than others. Some excellent sources of stem cells, such as bone marrow, peripheral blood, cord blood, other tissue stem cells and human embryos, which last one are controversial and their use can be illegal in some countries. Cord blood is a sample of blood taken from a newborn baby's umbilical cord. It is a rich source of stem cells, umbilical cord blood and tissue are collected from material that normally has no use following a child’s birth. Umbilical cord blood and tissue cells are rich sources of stem cells, which have been used in the treatment of over 80 diseases including leukemia, lymphoma and anemia as bone marrow stem cell potency.  The most common disease category has been leukemia. The next largest group is inherited diseases. Patients with lymphoma, myelodysplasia and severe aplastic anemia have also been successfully transplanted with cord blood. Cord blood is obtained by syringing out the placenta through the umbilical cord at the time of childbirth, after the cord has been detached from the newborn. Collecting stem cells from umbilical blood and tissue is ethical, pain-free, safe and simple. When they are needed to treat your child later in life, there will be no rejection or incompatibility issues, as the procedure will be using their own cells. In contrast, stem cells from donors do have these potential problems. By consider about cord blood potency, cord blood banks (familial or public were established. In IRAN, four cord blood banks has activity, Shariati BMT center cord blood bank, Royan familial cord blood banks, Royan public cord blood banks and Iranian Blood Transfusion Organ cord blood banks. Despite 50,000 sample which storage in these banks, but the

  16. Radiation Counting System Software Using Visual Basic

    International Nuclear Information System (INIS)

    Nanda Nagara; Didi Gayani

    2009-01-01

    It has been created a Gamma Radiation Counting System using interface card, which paired with Personal Computer (PC) and operated by the Visual Basic program. The program was set through varied menu selections such as ”Multi Counting” , ”Counting and Record” and ”View Data”. An interface card for data acquisition was formed by using AMD9513 components as a counter and timer which can be programmed. This counting system was tested and used in waste facility in PTNBR and the result is quite good. (author)

  17. Algorithm for counting large directed loops

    Energy Technology Data Exchange (ETDEWEB)

    Bianconi, Ginestra [Abdus Salam International Center for Theoretical Physics, Strada Costiera 11, 34014 Trieste (Italy); Gulbahce, Natali [Theoretical Division and Center for Nonlinear Studies, Los Alamos National Laboratory, NM 87545 (United States)

    2008-06-06

    We derive a Belief-Propagation algorithm for counting large loops in a directed network. We evaluate the distribution of the number of small loops in a directed random network with given degree sequence. We apply the algorithm to a few characteristic directed networks of various network sizes and loop structures and compare the algorithm with exhaustive counting results when possible. The algorithm is adequate in estimating loop counts for large directed networks and can be used to compare the loop structure of directed networks and their randomized counterparts.

  18. Counts and colors of faint galaxies

    International Nuclear Information System (INIS)

    Kron, R.G.

    1980-01-01

    The color distribution of faint galaxies is an observational dimension which has not yet been fully exploited, despite the important constraints obtainable for galaxy evolution and cosmology. Number-magnitude counts alone contain very diluted information about the state of things because galaxies from a wide range in redshift contribute to the counts at each magnitude. The most-frequently-seen type of galaxy depends on the luminosity function and the relative proportions of galaxies of different spectral classes. The addition of color as a measured quantity can thus considerably sharpen the interpretation of galaxy counts since the apparent color depends on the redshift and rest-frame spectrum. (Auth.)

  19. Thrombocytopenia responding to red blood cell transfusion

    International Nuclear Information System (INIS)

    Mubarak, Ahmad A.; Awidi, Abdalla; Rasul, Kakil I.; Al-Homsi, Ussama

    2004-01-01

    Three patients with severe symptomatic iron defficiency anemia and thrombocytopenia had a significant rise in the platelet count a few days following packed red blood cell transfusion. Pretransfusion platelet count of of patient one was 17x10/L. 22x10/Lin patient two and 29x10/L in patient three. On the 6th day of post tranfusion, the platelet count rose to 166x10/Lin patient one, 830x10/L in patient two and 136x10/L in patient three. The possible mechcnism behind such an unreported observation are discussed. (author)

  20. Skin tags: A link between lesional mast cell count/tryptase expression and obesity and dyslipidemia

    Directory of Open Access Journals (Sweden)

    Samar Abdallah M Salem

    2013-01-01

    Full Text Available Background:The etiology of skin tags (STs is not fully understood. A relation to diabetes mellitus and obesity was suggested. Few studies of possible mast cells (MCs involvement were reported. Tyrptase is a mast cell mediator and a potent fibroblast growth factor. It may provide a molecular link between mast cell activation and fibrosis. Aims: The aim was to assess clinical and laboratory findings in patients with STs, and the possible link between obesity, dyslipidemia, and lesional MC count/tryptase expression. Materials and Methods: A total of 20 patients with STs were subjected to clinical examination, estimation of body mass index (BMI, fasting blood glucose (FBG, postprandial blood glucose (PPBG, serum cholesterol and triglycerides, abdominal ultrasound for fatty liver assessment, in addition to study of MCs through staining for MC tryptase in two skin biopsies; lesional and nonlesional (control. Results:All patients showed abnormally high BMI and hypertriglyceridemia, with abnormal sonographic pattern in 15 patients (75%. STs number positively correlated with the age of patients. STs showed significantly higher MC counts and tryptase expression, compared with control skin ( P < 0.001, with no correlation of the STs number or MC count with BMI, FBG, PPBG or serum cholesterol. Obese patients showed a significantly higher MC count than overweight and there was a positive correlation between MC count and serum triglycerides. Axilla and under breast STs showed a higher MC count compared with other sites. Conclusions:STs seem to be related to obesity and hypertriglyceridemia. MCs with their tryptase are possibly involved in pathogenesis of STs. MC count is related to the associated factors; obesity and serum triglycerides. MC tryptase expression is a reliable method for accurate tissue MC counting.

  1. Optimal method for collection of umbilical cord blood: an Egyptian trial for a public cord blood bank.

    Science.gov (United States)

    Bassiouny, M R; El-Chennawi, F; Mansour, A K; Yahia, S; Darwish, A

    2015-06-01

    Umbilical cord blood (UCB) contains stem cells and can be used as an alternative to bone marrow transplantation. Engraftment is dependent on the total nucleated cell (TNC) and CD34+ cell counts of the cord blood units. This study was designed to evaluate the effect of the method of collection of the UCB on the yield of the cord blood units. Informed consent was obtained from 100 eligible mothers for donation of cord blood. Both in utero and ex utero methods were used for collection. The cord blood volume was measured. The TNC and the CD34+ cell counts were enumerated. We have found that in utero collection gave significantly larger volumes of cord blood and higher TNC counts than ex utero collection. There was no significant difference between both methods regarding the CD34+ cell counts. This study revealed a significant correlation between the volume of the collected cord blood and both TNC and CD34+ cell counts. It is better to collect cord blood in utero before placental delivery to optimize the quality of the cord blood unit. © 2015 AABB.

  2. Cardiac blood pool emission tomography

    International Nuclear Information System (INIS)

    Itti, R.; Philippe, L.; Lorgeron, J.M.; Charbonnier, B.; Raynaud, P.; Brochier, M.

    1983-01-01

    After blood pool labeling using technetium-99m, a series of cardiac pictures is acquired during the rotation of a gamma-camera about the patient. Computer processing leads to reconstruction of various tomographic slices from the original planar projection. Electrocardiographic gating selects the different phases of the cardiac cycle. Individual slices through the left ventricular region are added in order to provide ''thick'' slices on which global and regional parameters of the left ventricular function can be determined. Due to the proportionality existing between count rates and labeled blood volumes, any geometrical model can be avoided. The delineation of regions of interest for count integration is made easier due to the absence of superimposition of structures; no correction for background is necessary. Tomography thus appears to be more consistent and more accurate than the classical methods using planar projections. In addition, right ventricular morphological and kinetic studies can be performed in the same conditions as for the left ventricle [fr

  3. A measurement technique for counting processes

    International Nuclear Information System (INIS)

    Cantoni, V.; Pavia Univ.; De Lotto, I.; Valenziano, F.

    1980-01-01

    A technique for the estimation of first and second order properties of a stationary counting process is presented here which uses standard instruments for analysis of a continuous stationary random signal. (orig.)

  4. Why calories count: from science to politics

    National Research Council Canada - National Science Library

    Nestle, Marion; Nesheim, Malden C

    2012-01-01

    .... They are also hard to understand. In Why Calories Count, Marion Nestle and Malden Nesheim explain in clear and accessible language what calories are and how they work, both biologically and politically...

  5. CoC Housing Inventory Count Reports

    Data.gov (United States)

    Department of Housing and Urban Development — Continuum of Care (CoC) Homeless Assistance Programs Housing Inventory Count Reports are a snapshot of a CoC’s housing inventory, available at the national and state...

  6. VSRR Provisional Drug Overdose Death Counts

    Data.gov (United States)

    U.S. Department of Health & Human Services — This data contains provisional counts for drug overdose deaths based on a current flow of mortality data in the National Vital Statistics System. National...

  7. Regression Models For Multivariate Count Data.

    Science.gov (United States)

    Zhang, Yiwen; Zhou, Hua; Zhou, Jin; Sun, Wei

    2017-01-01

    Data with multivariate count responses frequently occur in modern applications. The commonly used multinomial-logit model is limiting due to its restrictive mean-variance structure. For instance, analyzing count data from the recent RNA-seq technology by the multinomial-logit model leads to serious errors in hypothesis testing. The ubiquity of over-dispersion and complicated correlation structures among multivariate counts calls for more flexible regression models. In this article, we study some generalized linear models that incorporate various correlation structures among the counts. Current literature lacks a treatment of these models, partly due to the fact that they do not belong to the natural exponential family. We study the estimation, testing, and variable selection for these models in a unifying framework. The regression models are compared on both synthetic and real RNA-seq data.

  8. Count rate effect in proportional counters

    International Nuclear Information System (INIS)

    Bednarek, B.

    1980-01-01

    A new concept is presented explaining changes in spectrometric parameters of proportional counters which occur due to varying count rate. The basic feature of this concept is that the gas gain of the counter remains constant in a wide range of count rate and that the decrease in the pulse amplitude and the detorioration of the energy resolution observed are the results of changes in the shape of original current pulses generated in the active volume of the counter. In order to confirm the validity of this statement, measurements of the gas amplification factor have been made in a wide count rate range. It is shown that above a certain critical value the gas gain depends on both the operating voltage and the count rate. (author)

  9. Atom counting with accelerator mass spectrometry

    International Nuclear Information System (INIS)

    Kutschera, Walter

    1995-01-01

    A brief review of the current status and some recent applications of accelerator mass spectrometry (AMS) are presented. Some connections to resonance ionization mass spectroscopy (RIS) as the alternate atom counting method are discussed

  10. Internal dosimetry by whole body counting techniques

    International Nuclear Information System (INIS)

    Sharma, R.C.

    1995-01-01

    Over decades, whole body counting and bioassay - the two principal methods of internal dosimetry have been most widely used to assess, limit and control the intakes of radioactive materials and the consequent internal doses by the workers in nuclear industry. This paper deals with the whole body counting techniques. The problems inherent in the interpretation of monitoring data and likely future directions of development in the assessments of internal doses by direct methods are outlined. (author). 14 refs., 9 figs., 1 tab

  11. How to count an introduction to combinatorics

    CERN Document Server

    Allenby, RBJT

    2010-01-01

    What's It All About? What Is Combinatorics? Classic Problems What You Need to Know Are You Sitting Comfortably? Permutations and Combinations The Combinatorial Approach Permutations CombinationsApplications to Probability Problems The Multinomial Theorem Permutations and Cycles Occupancy Problems Counting the Solutions of Equations New Problems from Old A ""Reduction"" Theorem for the Stirling Numbers The Inclusion-Exclusion Principle Double Counting Derangements A Formula for the Stirling NumbersStirling and Catalan Numbers Stirling Numbers Permutations and Stirling Numbers Catalan Numbers Pa

  12. Accuracy and precision in activation analysis: counting

    International Nuclear Information System (INIS)

    Becker, D.A.

    1974-01-01

    Accuracy and precision in activation analysis was investigated with regard to counting of induced radioactivity. The various parameters discussed include configuration, positioning, density, homogeneity, intensity, radioisotopic purity, peak integration, and nuclear constants. Experimental results are presented for many of these parameters. The results obtained indicate that counting errors often contribute significantly to the inaccuracy and imprecision of analyses. The magnitude of these errors range from less than 1 percent to 10 percent or more in many cases

  13. Remote system for counting of nuclear pulses

    International Nuclear Information System (INIS)

    Nieves V, J.A.; Garcia H, J.M.; Aguilar B, M.A.

    1999-01-01

    In this work, it is describe technically the remote system for counting of nuclear pulses, an integral system of the project radiological monitoring in a petroleum distillation tower. The system acquires the counting of incident nuclear particles in a nuclear detector which process this information and send it in serial form, using the RS-485 toward a remote receiver, which can be a Personal computer or any other device capable to interpret the communication protocol. (Author)

  14. Use of the lymphocyte count as a diagnostic screen in adults with suspected Epstein-Barr virus infectious mononucleosis.

    Science.gov (United States)

    Biggs, Timothy C; Hayes, Stephen M; Bird, Jonathan H; Harries, Philip G; Salib, Rami J

    2013-10-01

    To evaluate the predictive diagnostic accuracy of the lymphocyte count in Epstein-Barr virus-related infectious mononucleosis (IM). Retrospective case note and blood results review within a university-affiliated teaching hospital. A retrospective review of 726 patients undergoing full blood count and Monospot testing was undertaken. Monospot testing outcomes were compared with the lymphocyte count, examining for significant statistical correlations. With a lymphocyte count of ≤4 × 10(9) /L, 99% of patients had an associated negative Monospot result (sensitivity of 84% and specificity of 94%). A group subanalysis of the population older than 18 years with a lymphocyte count ≤4 × 10(9) /L revealed that 100% were Monospot negative (sensitivity of 100% and specificity of 97%). A lymphocyte count of ≤4 × 10(9) /L correlated significantly with a negative Monospot result. A lymphocyte count of ≤4 × 10(9) /L appears to be a highly reliable predictor of a negative Monospot result, particularly in the population aged >18 years. Pediatric patients, and adults with strongly suggestive symptoms and signs of IM, should still undergo Monospot testing. However, in adults with more subtle symptoms and signs, representing the vast majority, Monospot testing should be restricted to those with a lymphocyte count >4 × 10(9) /L. NA Copyright © 2013 The American Laryngological, Rhinological and Otological Society, Inc.

  15. Recursive algorithms for phylogenetic tree counting.

    Science.gov (United States)

    Gavryushkina, Alexandra; Welch, David; Drummond, Alexei J

    2013-10-28

    In Bayesian phylogenetic inference we are interested in distributions over a space of trees. The number of trees in a tree space is an important characteristic of the space and is useful for specifying prior distributions. When all samples come from the same time point and no prior information available on divergence times, the tree counting problem is easy. However, when fossil evidence is used in the inference to constrain the tree or data are sampled serially, new tree spaces arise and counting the number of trees is more difficult. We describe an algorithm that is polynomial in the number of sampled individuals for counting of resolutions of a constraint tree assuming that the number of constraints is fixed. We generalise this algorithm to counting resolutions of a fully ranked constraint tree. We describe a quadratic algorithm for counting the number of possible fully ranked trees on n sampled individuals. We introduce a new type of tree, called a fully ranked tree with sampled ancestors, and describe a cubic time algorithm for counting the number of such trees on n sampled individuals. These algorithms should be employed for Bayesian Markov chain Monte Carlo inference when fossil data are included or data are serially sampled.

  16. Preverbal and verbal counting and computation.

    Science.gov (United States)

    Gallistel, C R; Gelman, R

    1992-08-01

    We describe the preverbal system of counting and arithmetic reasoning revealed by experiments on numerical representations in animals. In this system, numerosities are represented by magnitudes, which are rapidly but inaccurately generated by the Meck and Church (1983) preverbal counting mechanism. We suggest the following. (1) The preverbal counting mechanism is the source of the implicit principles that guide the acquisition of verbal counting. (2) The preverbal system of arithmetic computation provides the framework for the assimilation of the verbal system. (3) Learning to count involves, in part, learning a mapping from the preverbal numerical magnitudes to the verbal and written number symbols and the inverse mappings from these symbols to the preverbal magnitudes. (4) Subitizing is the use of the preverbal counting process and the mapping from the resulting magnitudes to number words in order to generate rapidly the number words for small numerosities. (5) The retrieval of the number facts, which plays a central role in verbal computation, is mediated via the inverse mappings from verbal and written numbers to the preverbal magnitudes and the use of these magnitudes to find the appropriate cells in tabular arrangements of the answers. (6) This model of the fact retrieval process accounts for the salient features of the reaction time differences and error patterns revealed by experiments on mental arithmetic. (7) The application of verbal and written computational algorithms goes on in parallel with, and is to some extent guided by, preverbal computations, both in the child and in the adult.

  17. Seed counting system evaluation using arduino microcontroller

    Directory of Open Access Journals (Sweden)

    Paulo Fernando Escobar Paim

    2018-01-01

    Full Text Available The development of automated systems has been highlighted in the most diverse productive sectors, among them, the agricultural sector. These systems aim to optimize activities by increasing operational efficiency and quality of work. In this sense, the present work has the objective of evaluating a prototype developed for seed count in laboratory, using Arduino microcontroller. The prototype of the system for seed counting was built using a dosing mechanism commonly used in seeders, electric motor, Arduino Uno, light dependent resistor and light emitting diode. To test the prototype, a completely randomized design (CRD was used in a two-factorial scheme composed of three groups defined according to the number of seeds (500, 1000 and 1500 seeds tested, three speeds of the dosing disc that allowed the distribution in 17, 21 and 32 seeds per second, with 40 repetitions evaluating the seed counting prototype performance in different speeds. The prototype of the bench counter showed a moderate variability of seed number of counted within the nine tests and a high precision in the seed count on the distribution speeds of 17 and 21 seeds per second (s-1 up to 1500 seeds tested. Therefore, based on the observed results, the developed prototype presents itself as an excellent tool for counting seeds in laboratory.

  18. The Eosinophil Count Tends to Be Negatively Associated with Levels of Serum Glucose in Patients with Adrenal Cushing Syndrome

    Directory of Open Access Journals (Sweden)

    Younghak Lee

    2017-09-01

    Full Text Available BackgroundCushing syndrome is characterized by glucose intolerance, cardiovascular disease, and an enhanced systemic inflammatory response caused by chronic exposure to excess cortisol. Eosinopenia is frequently observed in patients with adrenal Cushing syndrome, but the relationship between the eosinophil count in peripheral blood and indicators of glucose level in patients with adrenal Cushing syndrome has not been determined.MethodsA retrospective study was undertaken of the clinical and laboratory findings of 40 patients diagnosed with adrenal Cushing syndrome at Chungnam National University Hospital from January 2006 to December 2016. Clinical characteristics, complete blood cell counts with white blood cell differential, measures of their endocrine function, description of imaging studies, and pathologic findings were obtained from their medical records.ResultsEosinophil composition and count were restored by surgical treatment of all of the patients with adrenal Cushing disease. The eosinophil count was inversely correlated with serum and urine cortisol, glycated hemoglobin, and inflammatory markers in the patients with adrenal Cushing syndrome.ConclusionSmaller eosinophil populations in patients with adrenal Cushing syndrome tend to be correlated with higher levels of blood sugar and glycated hemoglobin. This study suggests that peripheral blood eosinophil composition or count may be associated with serum glucose levels in patients with adrenal Cushing syndrome.

  19. The Eosinophil Count Tends to Be Negatively Associated with Levels of Serum Glucose in Patients with Adrenal Cushing Syndrome.

    Science.gov (United States)

    Lee, Younghak; Yi, Hyon Seung; Kim, Hae Ri; Joung, Kyong Hye; Kang, Yea Eun; Lee, Ju Hee; Kim, Koon Soon; Kim, Hyun Jin; Ku, Bon Jeong; Shong, Minho

    2017-09-01

    Cushing syndrome is characterized by glucose intolerance, cardiovascular disease, and an enhanced systemic inflammatory response caused by chronic exposure to excess cortisol. Eosinopenia is frequently observed in patients with adrenal Cushing syndrome, but the relationship between the eosinophil count in peripheral blood and indicators of glucose level in patients with adrenal Cushing syndrome has not been determined. A retrospective study was undertaken of the clinical and laboratory findings of 40 patients diagnosed with adrenal Cushing syndrome at Chungnam National University Hospital from January 2006 to December 2016. Clinical characteristics, complete blood cell counts with white blood cell differential, measures of their endocrine function, description of imaging studies, and pathologic findings were obtained from their medical records. Eosinophil composition and count were restored by surgical treatment of all of the patients with adrenal Cushing disease. The eosinophil count was inversely correlated with serum and urine cortisol, glycated hemoglobin, and inflammatory markers in the patients with adrenal Cushing syndrome. Smaller eosinophil populations in patients with adrenal Cushing syndrome tend to be correlated with higher levels of blood sugar and glycated hemoglobin. This study suggests that peripheral blood eosinophil composition or count may be associated with serum glucose levels in patients with adrenal Cushing syndrome. Copyright © 2017 Korean Endocrine Society

  20. Blood conservation with membrane oxygenators and dipyridamole.

    Science.gov (United States)

    Teoh, K H; Christakis, G T; Weisel, R D; Madonik, M M; Ivanov, J; Wong, P Y; Mee, A V; Levitt, D; Benak, A; Reilly, P

    1987-07-01

    Cardiopulmonary bypass induces platelet activation and dysfunction, which result in platelet deposition and depletion. Reduced platelet numbers and abnormal platelet function may contribute to postoperative bleeding. A membrane oxygenator may preserve platelets and reduce bleeding more than a bubble oxygenator, and the antiplatelet agent dipyridamole may protect platelets intraoperatively and reduce bleeding postoperatively. A prospective randomized trial was performed in 44 patients undergoing elective coronary artery bypass grafting to assess the effects of the membrane oxygenator and dipyridamole on platelet counts, platelet activation products, and postoperative bleeding. Patients who were randomized to receive a bubble oxygenator and no dipyridamole had the lowest postoperative platelet counts, the greatest blood loss, and the most blood products transfused. Platelet counts were highest and blood loss was least in patients randomized to receive a membrane oxygenator and dipyridamole (p less than .05). A bubble oxygenator with dipyridamole and a membrane oxygenator without dipyridamole resulted in intermediate postoperative platelet counts and blood loss. Arterial thromboxane B2 and platelet factor 4 concentrations were elevated on cardiopulmonary bypass in all groups. Both the membrane oxygenator and dipyridamole were independently effective (by multivariate analysis) in preserving platelets. Optimal blood conservation was achieved with a membrane oxygenator and dipyridamole.

  1. Automated cell counts on CSF samples: A multicenter performance evaluation of the GloCyte system.

    Science.gov (United States)

    Hod, E A; Brugnara, C; Pilichowska, M; Sandhaus, L M; Luu, H S; Forest, S K; Netterwald, J C; Reynafarje, G M; Kratz, A

    2018-02-01

    Automated cell counters have replaced manual enumeration of cells in blood and most body fluids. However, due to the unreliability of automated methods at very low cell counts, most laboratories continue to perform labor-intensive manual counts on many or all cerebrospinal fluid (CSF) samples. This multicenter clinical trial investigated if the GloCyte System (Advanced Instruments, Norwood, MA), a recently FDA-approved automated cell counter, which concentrates and enumerates red blood cells (RBCs) and total nucleated cells (TNCs), is sufficiently accurate and precise at very low cell counts to replace all manual CSF counts. The GloCyte System concentrates CSF and stains RBCs with fluorochrome-labeled antibodies and TNCs with nucleic acid dyes. RBCs and TNCs are then counted by digital image analysis. Residual adult and pediatric CSF samples obtained for clinical analysis at five different medical centers were used for the study. Cell counts were performed by the manual hemocytometer method and with the GloCyte System following the same protocol at all sites. The limits of the blank, detection, and quantitation, as well as precision and accuracy of the GloCyte, were determined. The GloCyte detected as few as 1 TNC/μL and 1 RBC/μL, and reliably counted as low as 3 TNCs/μL and 2 RBCs/μL. The total coefficient of variation was less than 20%. Comparison with cell counts obtained with a hemocytometer showed good correlation (>97%) between the GloCyte and the hemocytometer, including at very low cell counts. The GloCyte instrument is a precise, accurate, and stable system to obtain red cell and nucleated cell counts in CSF samples. It allows for the automated enumeration of even very low cell numbers, which is crucial for CSF analysis. These results suggest that GloCyte is an acceptable alternative to the manual method for all CSF samples, including those with normal cell counts. © 2017 John Wiley & Sons Ltd.

  2. Photon counting and fluctuation of molecular movement

    International Nuclear Information System (INIS)

    Inohara, Koichi

    1978-01-01

    The direct measurement of the fluctuation of molecular motions, which provides with useful information on the molecular movement, was conducted by introducing photon counting method. The utilization of photon counting makes it possible to treat the molecular system consisting of a small number of molecules like a radioisotope in the detection of a small number of atoms, which are significant in biological systems. This method is based on counting the number of photons of the definite polarization emitted in a definite time interval from the fluorescent molecules excited by pulsed light, which are bound to the marked large molecules found in a definite spatial region. Using the probability of finding a number of molecules oriented in a definite direction in the definite spatial region, the probability of counting a number of photons in a definite time interval can be calculated. Thus the measurable count rate of photons can be related with the fluctuation of molecular movement. The measurement was carried out under the condition, in which the probability of the simultaneous arrival of more than two photons at a detector is less than 1/100. As the experimental results, the resolving power of photon-counting apparatus, the frequency distribution of the number of photons of some definite polarization counted for 1 nanosecond are shown. In the solution, the variance of the number of molecules of 500 on the average is 1200, which was estimated from the experimental data by assuming normal distribution. This departure from the Poisson distribution means that a certain correlation does exist in molecular movement. In solid solution, no significant deviation was observed. The correlation existing in molecular movement can be expressed in terms of the fluctuation of the number of molecules. (Nakai, Y.)

  3. Leukocytic Response and Peripheral Venous Blood Lymphocyte Apoptosis as a Marker of Tissue Ischemia in Acute Massive Blood Loss

    Directory of Open Access Journals (Sweden)

    N. V. Borovkova

    2013-01-01

    Full Text Available Objective: to estimate the level of peripheral venous blood lymphocyte apoptosis and intraoperative hypoxia in victims with acute massive blood loss. Subjects and methods. Twenty-two patients with open and close chest and abdominal traumas complicated by acute massive blood loss were examined. All the patients were emergently operated on to stop bleeding. Tissue metabolism was evaluated from gases, acid-base parameters, and plasma lactate, glucose, potassium, and sodium levels. Apoptosis of mononuclear cells was studied and dead leukocytes were counted using flow cytometry. Results. Preoperatively, the victims were found to have venous hypoxemia, hyperlactatemia, hyperglycemia, moderate leukocytosis, and higher dead leukocyte counts. There were also raised counts of lymphocytes coming into the process of apoptosis. A significant relationship was found between monocyte counts and hypoxia values. At the end of surgery, oxygen balance values became stable and exerted an effect on the count of leukocytes, the relative level of granulocytes, the relative and absolute counts of dead and damaged leukocytes, and the concentration of lymphocytes in the victims’ venous blood during the early stages of apoptosis, as evidenced by nonlinear regression models. Conclusion. The indicators of immunocompetent cell apoptosis and the count of venous blood dead leukocytes along with lactate levels and venous hypoxemia parameters reflect the degree of tissue hypoxia and may be used as specific markers.

  4. Blood irradiation

    International Nuclear Information System (INIS)

    Chandy, Mammen

    1998-01-01

    Viable lymphocytes are present in blood and cellular blood components used for transfusion. If the patient who receives a blood transfusion is immunocompetent these lymphocytes are destroyed immediately. However if the patient is immunodefficient or immunosuppressed the transfused lymphocytes survive, recognize the recipient as foreign and react producing a devastating and most often fatal syndrome of transfusion graft versus host disease [T-GVHD]. Even immunocompetent individuals can develop T-GVHD if the donor is a first degree relative since like the Trojan horse the transfused lymphocytes escape detection by the recipient's immune system, multiply and attack recipient tissues. T-GVHD can be prevented by irradiating the blood and different centers use doses ranging from 1.5 to 4.5 Gy. All transfusions where the donor is a first degree relative and transfusions to neonates, immunosuppressed patients and bone marrow transplant recipients need to be irradiated. Commercial irradiators specifically designed for irradiation of blood and cellular blood components are available: however they are expensive. India needs to have blood irradiation facilities available in all large tertiary institutions where immunosuppressed patients are treated. The Atomic Energy Commission of India needs to develop a blood irradiator which meets international standards for use in tertiary medical institutions in the country. (author)

  5. BLOOD DONATION

    CERN Document Server

    SC Unit

    2008-01-01

    A blood donation, organized by EFS (Etablissement Français du Sang) of Annemasse will take place On Wednesday 12 November 2008, from 8:30 to 16:00, at CERN Restaurant 2 If possible, please, bring your blood group Card.

  6. Blood donation

    CERN Multimedia

    GS Department

    2009-01-01

    A blood donation is organised by the Cantonal Hospital of Geneva On Thursday 19 March 2009 from 9 a.m. to 5 p.m. CERN RESTAURANT 2 Number of donations during the last blood donations :135 donors in July 2008 122 donors in November 2008 Let’s do better in 2009 !!! Give 30 minutes of your time to save lives...

  7. Noun Countability; Count Nouns and Non-count Nouns, What are the Syntactic Differences Between them?

    Directory of Open Access Journals (Sweden)

    Azhar A. Alkazwini

    2016-11-01

    Full Text Available Words that function as the subjects of verbs, objects of verbs or prepositions and which can have a plural form and possessive ending are known as nouns. They are described as referring to persons, places, things, states, or qualities and might also be used as an attributive modifier. In this paper, classes and subclasses of nouns shall be presented, then, noun countability branching into count and non-count nous shall be discussed. A number of present examples illustrating differences between count and non-count nouns and this includes determiner-head-co-occurrence restrictions of number, subject-verb agreement, in addition to some exceptions to this agreement rule shall be discussed. Also, the lexically inherent number in nouns and how inherently plural nouns are classified in terms of (+/- count are illustrated. This research will discuss partitive construction of count and non-count nouns, nouns as attributive modifier and, finally, conclude with the fact that there are syntactic difference between count and non-count in the English Language.

  8. Benjamin Thompson, Count Rumford Count Rumford on the nature of heat

    CERN Document Server

    Brown, Sanborn C

    1967-01-01

    Men of Physics: Benjamin Thompson - Count Rumford: Count Rumford on the Nature of Heat covers the significant contributions of Count Rumford in the fields of physics. Count Rumford was born with the name Benjamin Thompson on March 23, 1753, in Woburn, Massachusetts. This book is composed of two parts encompassing 11 chapters, and begins with a presentation of Benjamin Thompson's biography and his interest in physics, particularly as an advocate of an """"anti-caloric"""" theory of heat. The subsequent chapters are devoted to his many discoveries that profoundly affected the physical thought

  9. Effect of Graded Levels of Soybean Hull on Blood, Carcass and ...

    African Journals Online (AJOL)

    Each treatment was replicated 3 times with 2 pigs per replicate placed on concrete-floored pens. ... Results showed that pigs fed the control diets had comparable (p>0.05) packed cell volume (PCV), hemoglobin concentration (Hb), red blood cell counts (RBC), white blood cell counts (WBC), mean corpuscular hemoglobin ...

  10. It counts who counts: an experimental evaluation of the importance of observer effects on spotlight count estimates

    DEFF Research Database (Denmark)

    Sunde, Peter; Jessen, Lonnie

    2013-01-01

    observers with respect to their ability to detect and estimate distance to realistic animal silhouettes at different distances. Detection probabilities were higher for observers experienced in spotlighting mammals than for inexperienced observers, higher for observers with a hunting background compared...... with non-hunters and decreased as function of age but were independent of sex or educational background. If observer-specific detection probabilities were applied to real counting routes, point count estimates from inexperienced observers without a hunting background would only be 43 % (95 % CI, 39...

  11. Protecting count queries in study design.

    Science.gov (United States)

    Vinterbo, Staal A; Sarwate, Anand D; Boxwala, Aziz A

    2012-01-01

    Today's clinical research institutions provide tools for researchers to query their data warehouses for counts of patients. To protect patient privacy, counts are perturbed before reporting; this compromises their utility for increased privacy. The goal of this study is to extend current query answer systems to guarantee a quantifiable level of privacy and allow users to tailor perturbations to maximize the usefulness according to their needs. A perturbation mechanism was designed in which users are given options with respect to scale and direction of the perturbation. The mechanism translates the true count, user preferences, and a privacy level within administrator-specified bounds into a probability distribution from which the perturbed count is drawn. Users can significantly impact the scale and direction of the count perturbation and can receive more accurate final cohort estimates. Strong and semantically meaningful differential privacy is guaranteed, providing for a unified privacy accounting system that can support role-based trust levels. This study provides an open source web-enabled tool to investigate visually and numerically the interaction between system parameters, including required privacy level and user preference settings. Quantifying privacy allows system administrators to provide users with a privacy budget and to monitor its expenditure, enabling users to control the inevitable loss of utility. While current measures of privacy are conservative, this system can take advantage of future advances in privacy measurement. The system provides new ways of trading off privacy and utility that are not provided in current study design systems.

  12. Delta count-rate monitoring system

    International Nuclear Information System (INIS)

    Van Etten, D.; Olsen, W.A.

    1985-01-01

    A need for a more effective way to rapidly search for gamma-ray contamination over large areas led to the design and construction of a very sensitive gamma detection system. The delta count-rate monitoring system was installed in a four-wheel-drive van instrumented for environmental surveillance and accident response. The system consists of four main sections: (1) two scintillation detectors, (2) high-voltage power supply amplifier and single-channel analyzer, (3) delta count-rate monitor, and (4) count-rate meter and recorder. The van's 6.5-kW generator powers the standard nuclear instrument modular design system. The two detectors are mounted in the rear corners of the van and can be run singly or jointly. A solid-state bar-graph count-rate meter mounted on the dashboard can be read easily by both the driver and passenger. A solid-state strip chart recorder shows trends and provides a permanent record of the data. An audible alarm is sounded at the delta monitor and at the dashboard count-rate meter if a detected radiation level exceeds the set background level by a predetermined amount

  13. Platelet Counts in Insoluble Platelet-Rich Fibrin Clots: A Direct Method for Accurate Determination

    Directory of Open Access Journals (Sweden)

    Yutaka Kitamura

    2018-02-01

    Full Text Available Platelet-rich fibrin (PRF clots have been used in regenerative dentistry most often, with the assumption that growth factor levels are concentrated in proportion to the platelet concentration. Platelet counts in PRF are generally determined indirectly by platelet counting in other liquid fractions. This study shows a method for direct estimation of platelet counts in PRF. To validate this method by determination of the recovery rate, whole-blood samples were obtained with an anticoagulant from healthy donors, and platelet-rich plasma (PRP fractions were clotted with CaCl2 by centrifugation and digested with tissue-plasminogen activator. Platelet counts were estimated before clotting and after digestion using an automatic hemocytometer. The method was then tested on PRF clots. The quality of platelets was examined by scanning electron microscopy and flow cytometry. In PRP-derived fibrin matrices, the recovery rate of platelets and white blood cells was 91.6 and 74.6%, respectively, after 24 h of digestion. In PRF clots associated with small and large red thrombi, platelet counts were 92.6 and 67.2% of the respective total platelet counts. These findings suggest that our direct method is sufficient for estimating the number of platelets trapped in an insoluble fibrin matrix and for determining that platelets are distributed in PRF clots and red thrombi roughly in proportion to their individual volumes. Therefore, we propose this direct digestion method for more accurate estimation of platelet counts in most types of platelet-enriched fibrin matrix.

  14. BMI in relation to sperm count

    DEFF Research Database (Denmark)

    Sermondade, N; Faure, C; Fezeu, L

    2013-01-01

    BACKGROUND The global obesity epidemic has paralleled a decrease in semen quality. Yet, the association between obesity and sperm parameters remains controversial. The purpose of this report was to update the evidence on the association between BMI and sperm count through a systematic review...... with meta-analysis. METHODS A systematic review of available literature (with no language restriction) was performed to investigate the impact of BMI on sperm count. Relevant studies published until June 2012 were identified from a Pubmed and EMBASE search. We also included unpublished data (n = 717 men...... studies were included in the meta-analysis, resulting in a sample of 13 077 men from the general population and attending fertility clinics. Data were stratified according to the total sperm count as normozoospermia, oligozoospermia and azoospermia. Standardized weighted mean differences in sperm...

  15. Multiple sample, radioactive particle counting apparatus

    International Nuclear Information System (INIS)

    Reddy, R.R.V.; Kelso, D.M.

    1978-01-01

    An apparatus is described for determining the respective radioactive particle sample count being emitted from radioactive particle containing samples. It includes means for modulating the information on the radioactive particles being emitted from the samples, coded detecting means for sequentially detecting different respective coded combinations of the radioactive particles emitted from more than one but less than all of the samples, and processing the modulated information to derive the sample count for each sample. It includes a single light emitting crystal next to a number of samples, an encoder belt sequentially movable between the crystal and the samples. The encoder belt has a coded array of apertures to provide corresponding modulated light pulses from the crystal, and a photomultiplier tube to convert the modulated light pulses to decodable electrical signals for deriving the respective sample count

  16. CERN_DxCTA counting mode chip

    CERN Document Server

    Moraes, D; Nygård, E

    2008-01-01

    This ASIC is a counting mode front-end electronic optimized for the readout of CdZnTe/CdTe and silicon sensors, for possible use in applications where the flux of ionizing radiation is high. The chip is implemented in 0.25 μm CMOS technology. The circuit comprises 128 channels equipped with a transimpedance amplifier followed by a gain shaper stage with 21 ns peaking time, two discriminators and two 18-bit counters. The channel architecture is optimized for the detector characteristics in order to achieve the best energy resolution at counting rates of up to 5 M counts/second. The amplifier shows a linear sensitivity of 118 mV/fC and an equivalent noise charge of about 711 e−, for a detector capacitance of 5 pF. Complete evaluation of the circuit is presented using electronic pulses and pixel detectors.

  17. CERNDxCTA counting mode chip

    International Nuclear Information System (INIS)

    Moraes, D.; Kaplon, J.; Nygard, E.

    2008-01-01

    This ASIC is a counting mode front-end electronic optimized for the readout of CdZnTe/CdTe and silicon sensors, for possible use in applications where the flux of ionizing radiation is high. The chip is implemented in 0.25 μm CMOS technology. The circuit comprises 128 channels equipped with a transimpedance amplifier followed by a gain shaper stage with 21 ns peaking time, two discriminators and two 18-bit counters. The channel architecture is optimized for the detector characteristics in order to achieve the best energy resolution at counting rates of up to 5 M counts/second. The amplifier shows a linear sensitivity of 118 mV/fC and an equivalent noise charge of about 711 e - , for a detector capacitance of 5 pF. Complete evaluation of the circuit is presented using electronic pulses and pixel detectors

  18. Detection limits for radioanalytical counting techniques

    International Nuclear Information System (INIS)

    Hartwell, J.K.

    1975-06-01

    In low-level radioanalysis it is usually necessary to test the sample net counts against some ''Critical Level'' in order to determine if a given result indicates detection. This is an interpretive review of the work by Nicholson (1963), Currie (1968) and Gilbert (1974). Nicholson's evaluation of three different computational formulas for estimation of the ''Critical Level'' is discussed. The details of Nicholson's evaluation are presented along with a basic discussion of the testing procedures used. Recommendations are presented for calculation of confidence intervals, for reporting of analytical results, and for extension of the derived formula to more complex cases such as multiple background counts, multiple use of a single background count, and gamma spectrometric analysis

  19. [Effects of HiLo for two weeks on erythrocyte immune adhesion and leukocyte count of swimmers].

    Science.gov (United States)

    Zhao, Yong-Cai; Gao, Bing-Hong; Wu, Ge-Lin; Zhang, Jiu-Li

    2012-07-01

    To investigate the effects of living high-training low (HiLo) on innate immunity in blood of elite swimmers. Six female swimmers undertook HiLo for two weeks, erythrocyte adhesion function and counts of leukocyte were tested in different time of training period. Red blood cell C3b receptor ring rate (RBC-C3bRR) decreased and red blood cell immune complex matter ring rate (RBC-ICR) increased significantly (P < 0.05), the two markers returned to base line 1 week after training. Counts of leukocyte and granulocyte decreased significantly (P < 0.05), and they recovered 1 week after training; Counts of lymphocyte and monocyte decreased without significance during training and did not recovered after training. Immunity of erythrocyte and granulocyte decreased quickly, but lymphocyte and monocyte recovered slowly, swimmers were adaptive to the training.

  20. Effects of plutonium redistribution on lung counting

    International Nuclear Information System (INIS)

    Swinth, K.L.

    1976-01-01

    Early counts of Pu deposition in lungs will tend to overestimate lung contents since calibrations are performed with a uniform distribution and since a more favorable geometry exists in contaminated subjects because the activity is closer to the periphery of the lungs. Although the concentration into the outer regions of the lungs continues as evidenced by the autopsy studies, the counts performed by L X-rays will probably underestimate the lung content; because, simplistically, the geometry several years after exposure consists of a spherical shell with a point of activity in the center. This point of activity represents concentration in the lymph nodes from which the 60 keV gamma of 241 Am will be counted, but from which few of the L X-rays will be counted (this is an example of interorgan distribution). When a correction is made to the L X-ray intensity, the lymph node contribution will tend to increase the amount subtracted while correcting for 241 Am X-rays. It is doubtful that the relative increase in X-ray intensity by concentration in the pleural and sub-pleural regions will compensate for this effect. This will make the plutonium burden disappear while the 241 Am can still be detected. This effect has been observed in a case where counts with an intraesophageal probe indicated a substantial lymph node burden. In order to improve the accuracy of in vivo plutonium measurements, an improved understanding of pulmonary distribution and of distribution effects on in vivo counting are required

  1. Thrombocyte counts in malaria patients at East Kalimantan

    Science.gov (United States)

    Siagian, L. R. D.; Asfirizal, V.; Toruan, V. D. L.; Hasanah, N.

    2018-04-01

    Malaria still becoming a serious health problem in Indonesia. Beside disorders of erythrocytes, there are some data that Plasmodium caused the other blood cells like leukocyte and thrombocyte. In malaria, changes of thrombocyte is thrombocytopenia that would be a complication from malaria vivax or malaria falciparum. The aim of this study is to know the thrombocyte count of malaria patients in East Kalimantan. Design of this study is descriptic retrospective from medical record’s data from 2011-2016 in 7 hospitals (AW Syahranie at Samarinda, Kanudjoso at Balikpapan, Penajam Paser Utara at Panajam, AM Parikesit at Tenggarong, Taman Husada at Bontang, Kudungga at Sangata and Abdul Rivai at Tanjung Redeb. We collected the data from June-August 2017. There are 1041 malaria patients with male and female respectively 88.2% and 11.2%. The etiology of malaria were Plasmodium falciparum, Plasmodium vivax and mixed infection (P.f and P.v) respectively 62.6%, 38% and 6.1%. We found thrombocyte count was normal, decrease and increase respectively 11%, 85% and 1.7%. The degree of thrombocytopenia in malaria patients were mild (100.000-150.000/µl) 31.8%, moderate (50.000-100.000/µL) 45.6% and severe (malaria patients at East Kalimantan was thrombocytopenia with moderate degree of thrombocytopenia.

  2. Count-to-count time interval distribution analysis in a fast reactor

    International Nuclear Information System (INIS)

    Perez-Navarro Gomez, A.

    1973-01-01

    The most important kinetic parameters have been measured at the zero power fast reactor CORAL-I by means of the reactor noise analysis in the time domain, using measurements of the count-to-count time intervals. (Author) 69 refs

  3. Compositions and process for liquid scintillation counting

    International Nuclear Information System (INIS)

    1974-01-01

    Liquid scintillation counting compositions which include certain polyethoxylated poly(oxypropylene) emulsifiers allow stable dispersion of aqueous or other samples merely by shaking. Preferred are mixtures of such emulsifiers which give homogeneous monophasic-appearing dispersions over wide ranges of temperature and aqueous sample content. Certain of these emulsifiers, without being mixed, are of particular advantage when used in analysis of samples obtained through radioimmunoassay techniques which are extremely difficult to disperse. Certain of these emulsifiers, also without being mixed, uniformly give homogeneous monophasic-appearing aqueous counting samples over much wider ranges of aqueous sample content and temperature than prior sample emulsifiers

  4. Counting dyons in N=4 string theory

    CERN Document Server

    Dijkgraaf, R; Verlinde, Herman L

    1997-01-01

    We present a microscopic index formula for the degeneracy of dyons in four-dimensional N=4 string theory. This counting formula is manifestly symmetric under the duality group, and its asymptotic growth reproduces the macroscopic Bekenstein-Hawking entropy. We give a derivation of this result in terms of the type II five-brane compactified on K3, by assuming that its fluctuations are described by a closed string theory on its world-volume. We find that the degeneracies are given in terms of the denominator of a generalized super Kac-Moody algebra. We also discuss the correspondence of this result with the counting of D-brane states.

  5. Isospectral discrete and quantum graphs with the same flip counts and nodal counts

    Science.gov (United States)

    Juul, Jonas S.; Joyner, Christopher H.

    2018-06-01

    The existence of non-isomorphic graphs which share the same Laplace spectrum (to be referred to as isospectral graphs) leads naturally to the following question: what additional information is required in order to resolve isospectral graphs? It was suggested by Band, Shapira and Smilansky that this might be achieved by either counting the number of nodal domains or the number of times the eigenfunctions change sign (the so-called flip count) (Band et al 2006 J. Phys. A: Math. Gen. 39 13999–4014 Band and Smilansky 2007 Eur. Phys. J. Spec. Top. 145 171–9). Recent examples of (discrete) isospectral graphs with the same flip count and nodal count have been constructed by Ammann by utilising Godsil–McKay switching (Ammann private communication). Here, we provide a simple alternative mechanism that produces systematic examples of both discrete and quantum isospectral graphs with the same flip and nodal counts.

  6. Association of BPD and IVH with early neutrophil and white counts in VLBW neonates with gestational age <32 weeks

    Science.gov (United States)

    Palta, Mari; Sadek-Badawi, Mona; Carlton, David P

    2008-01-01

    Objectives To investigate associations between early low neutrophil count from routine blood samples, white blood count (WBC), pregnancy complications and neonatal outcomes for very low birth weight infants (VLBW ≤1500g) with gestational age <32 weeks. Patients and Methods Information was abstracted on all infants admitted to level III NICUs in Wisconsin 2003-2004. 1002 (78%) had differential and corrected total white counts within 2 ½ hours of birth. Data analyses included frequency tables, binary logistic, ordinal logistc and ordinary regression. Results Low neutrophil count (<1000/μL) was strongly associated with low WBC, pregnancy complications and antenatal steroids. Low neutrophil count predicted bronchopulmonary dysplasia severity level (BPD) (OR: 1.7, 95% CI: 1.1-2.7) and intraventricular hemorrhage (IVH) grade (OR: 2.2, 95% CI: 1.3-3.8). Conclusions Early neutrophil counts may have multiple causes interfering with their routine use as an inflammatory marker. Nonetheless, low neutrophil count has consistent independent associations with outcomes. PMID:18563166

  7. Osmolality - blood

    Science.gov (United States)

    ... water loss Poisoning from harmful substances such as ethanol , methanol , or ethylene glycol Problems producing urine In ... may be due to: Diabetes insipidus High blood sugar level ( hyperglycemia ) High level of nitrogen waste products ...

  8. Tainted blood

    DEFF Research Database (Denmark)

    Deleuran, Ida; Sheikh, Zainab Afshan; Hoeyer, Klaus

    2015-01-01

    The existing literature on donor screening in transfusion medicine tends to distinguish between social concerns about discrimination and medical concerns about safety. In this article, we argue that the bifurcation into social and medical concerns is problematic. We build our case on a qualitative...... study of the historical rise and current workings of safety practices in the Danish blood system. Here, we identify a strong focus on contamination in order to avoid 'tainted blood', at the expense of working with risks that could be avoided through enhanced blood monitoring practices. Of further...... significance to this focus are the social dynamics found at the heart of safety practices aimed at avoiding contamination. We argue that such dynamics need more attention, in order to achieve good health outcomes in transfusion medicine. Thus, we conclude that, to ensure continuously safe blood systems, we...

  9. Blood Clots

    Science.gov (United States)

    ... sitting for long periods. If you travel by airplane, walk the aisle periodically. For long car trips, ... Your-Risk-for-Excessive-Blood-Clotting_UCM_448771_Article.jsp. Accessed April 18, 2016. What causes excessive ...

  10. Blood Clots

    Science.gov (United States)

    ... Pregnancy Immobility (including prolonged inactivity, long trips by plane or car ) Smoking Oral contraceptives Certain cancers Trauma Certain surgeries Age (increased risk for people over age 60) A family history of blood clots Chronic inflammatory diseases Diabetes High ...

  11. Moving blood.

    Science.gov (United States)

    Pelis, K

    1997-01-01

    Our internationally acclaimed journalist Sanguinia has returned safely from her historic assignment. Travelling from Homeric Greece to British Romanticism, she was witness to blood drinking, letting, bathing, and transfusion. In this report, she explores connections between the symbolic and the sadistic; the mythic and the medical--all in an effort to appreciate the layered meanings our culture has given to the movement of blood between our bodies.

  12. Colour measurement and white blood cell recognition

    CERN Document Server

    Gelsema, E S

    1972-01-01

    As a part of a collaboration with NEMCH aimed at the automation of the differential white blood cell count, studies have been made of the different possibilities for using colour to help in the recognition process. Results are presented comparing data obtained with a microspectrophotometer and with a simulated three-colour scanner.

  13. Biology of Blood

    Science.gov (United States)

    ... switch to the Professional version Home Blood Disorders Biology of Blood Overview of Blood Resources In This ... Version. DOCTORS: Click here for the Professional Version Biology of Blood Overview of Blood Components of Blood ...

  14. Blood Clotting and Pregnancy

    Medline Plus

    Full Text Available ... Blood Basics Blood Disorders Anemia Bleeding Disorders Blood Cancers Blood Clots Blood Clotting and Pregnancy Clots and ... Increased maternal age Other medical illness (e.g., cancer, infection) back to top How are Blood Clots ...

  15. Blood Clotting and Pregnancy

    Medline Plus

    Full Text Available ... all publications For Patients Blood Basics Blood Disorders Anemia Bleeding Disorders Blood Cancers Blood Clots Blood Clotting and Pregnancy Clots and Travel DVT Myths vs. Facts Blood ...

  16. Nevada Kids Count Data Book, 1997.

    Science.gov (United States)

    We Can, Inc., Las Vegas, NV.

    This Kids Count data book is the first to examine statewide indicators of the well being of Nevada's children. The statistical portrait is based on 15 indicators of child well being: (1) percent low birth-weight babies; (2) infant mortality rate; (3) percent of children in poverty; (4) percent of children in single-parent families; (5) percent of…

  17. Isospectral graphs with identical nodal counts

    International Nuclear Information System (INIS)

    Oren, Idan; Band, Ram

    2012-01-01

    According to a recent conjecture, isospectral objects have different nodal count sequences (Gnutzmann et al 2005 J. Phys. A: Math. Gen. 38 8921–33). We study generalized Laplacians on discrete graphs, and use them to construct the first non-trivial counterexamples to this conjecture. In addition, these examples demonstrate a surprising connection between isospectral discrete and quantum graphs. (paper)

  18. Phase-space quark counting rule

    Energy Technology Data Exchange (ETDEWEB)

    Wei-Gin, Chao; Lo, Shui-Yin [Academia Sinica, Beijing (China). Inst. of High Energy Physics

    1981-05-21

    A simple quark counting rule based on the phase-space consideration suggested before is used to fit all 39 recent experimental data points on inclusive reactions. Parameter-free relations are found to agree with experiments. Excellent detail fits are obtained for 11 inclusive reactions.

  19. Statistical tests to compare motif count exceptionalities

    Directory of Open Access Journals (Sweden)

    Vandewalle Vincent

    2007-03-01

    Full Text Available Abstract Background Finding over- or under-represented motifs in biological sequences is now a common task in genomics. Thanks to p-value calculation for motif counts, exceptional motifs are identified and represent candidate functional motifs. The present work addresses the related question of comparing the exceptionality of one motif in two different sequences. Just comparing the motif count p-values in each sequence is indeed not sufficient to decide if this motif is significantly more exceptional in one sequence compared to the other one. A statistical test is required. Results We develop and analyze two statistical tests, an exact binomial one and an asymptotic likelihood ratio test, to decide whether the exceptionality of a given motif is equivalent or significantly different in two sequences of interest. For that purpose, motif occurrences are modeled by Poisson processes, with a special care for overlapping motifs. Both tests can take the sequence compositions into account. As an illustration, we compare the octamer exceptionalities in the Escherichia coli K-12 backbone versus variable strain-specific loops. Conclusion The exact binomial test is particularly adapted for small counts. For large counts, we advise to use the likelihood ratio test which is asymptotic but strongly correlated with the exact binomial test and very simple to use.

  20. Photon counting with small pore microchannel plates

    International Nuclear Information System (INIS)

    Martindale, A.; Lapington, J.S.; Fraser, G.W.

    2007-01-01

    We describe the operation of microchannel plates (MCPs) with 3.2μm diameter channels as photon counting detectors of soft X-rays. Gain and temporal resolution measurements are compared with theoretical scaling laws for channel diameter. A minimum pulse width of 264ps is observed for a two stage multiplier at a total bias voltage of ∼1930V

  1. Alabama Kids Count 2002 Data Book.

    Science.gov (United States)

    Curtis, Apreill; Bogie, Don

    This Kids Count data book examines statewide trends in well-being of Alabamas children. The statistical portrait is based on 18 indicators in the areas of child health, education, safety, and security: (1) infant mortality rate; (2) low weight births; (3) child health index; (4) births to unmarried teens; (5) first grade retention; (6) school…

  2. Alabama Kids Count 2001 Data Book.

    Science.gov (United States)

    Curtis, Apreill; Bogie, Don

    This Kids Count data book examines statewide trends in well-being for Alabama's children. The statistical portrait is based on 17 indicators in the areas of health, education, safety, and security. The indicators are: (1) infant mortality rate; (2) low weight births; (3) child health index; (4) births to unmarried teens; (5) first grade retention;…

  3. Spontaneous Non-verbal Counting in Toddlers

    Science.gov (United States)

    Sella, Francesco; Berteletti, Ilaria; Lucangeli, Daniela; Zorzi, Marco

    2016-01-01

    A wealth of studies have investigated numerical abilities in infants and in children aged 3 or above, but research on pre-counting toddlers is sparse. Here we devised a novel version of an imitation task that was previously used to assess spontaneous focusing on numerosity (i.e. the predisposition to grasp numerical properties of the environment)…

  4. Stalking the count. Dracula, Fandom and Tourism

    NARCIS (Netherlands)

    S.L. Reijnders (Stijn)

    2011-01-01

    textabstractLarge numbers of tourists travel to Transylvania every year, looking for traces of Count Dracula. This article investigates why people feel the need to connect fictional stories, such as Dracula, with identifiable physical locations, and why they subsequently want to visit these

  5. Liquid scintillation counting (LSC) - an overview

    International Nuclear Information System (INIS)

    Ravi, S.; Mathew, K.M.

    2005-01-01

    In Liquid Scintillation Counting, the amount of light produced is proportional to the amount of radiation present in the sample and the energy of the light produced is proportional to the energy of the radiation that is present in the sample. This makes LSC a very convenient tool to measure radioactivity

  6. Counting Women's Work in Vietnam | IDRC - International ...

    International Development Research Centre (IDRC) Digital Library (Canada)

    2017-07-31

    Jul 31, 2017 ... These gender equality indicators are shedding light on girls' and women's ... Young people do a tremendous amount of unpaid care work at the ages when ... Read the report "Counting Women's Work in Vietnam" · View the ...

  7. Going Online to Make Learning Count

    Science.gov (United States)

    Brigham, Cathy; Klein-Collins, Rebecca

    2011-01-01

    Adult students often come to higher education with college-level learning that they have acquired outside of the classroom--from the workplace, military service, self-study, or hobbies. For decades, many forward-thinking colleges and universities have been offering services to evaluate that learning and award it college credit that counts towards…

  8. Health Advocacy--Counting the Costs

    Science.gov (United States)

    Dyall, Lorna; Marama, Maria

    2010-01-01

    Access to, and delivery of, safe and culturally appropriate health services is increasingly important in New Zealand. This paper will focus on counting the costs of health advocacy through the experience of a small non government charitable organisation, the Health Advocates Trust, (HAT) which aimed to provide advocacy services for a wide range of…

  9. The Fallacy of Word-Counts.

    Science.gov (United States)

    Engels, L.K.

    1968-01-01

    The greatest fallacy of word counts, the author maintains, lies in the fact that advocates of frequency lists stress the high percentage without telling the whole truth. It has become common to pretend that a frequency list of 3,000 words covers 95 percent of the language, that it enables a person to speak and understand a foreign language by…

  10. Counting Subspaces of a Finite Vector Space

    Indian Academy of Sciences (India)

    Home; Journals; Resonance – Journal of Science Education; Volume 15; Issue 11. Counting Subspaces of a Finite Vector Space – 1. Amritanshu Prasad. General Article Volume 15 Issue 11 November 2010 pp 977-987. Fulltext. Click here to view fulltext PDF. Permanent link:

  11. White blood cell subtypes and risk of type 2 diabetes.

    Science.gov (United States)

    Zhang, Hongmei; Yang, Zhen; Zhang, Weiwei; Niu, Yixin; Li, Xiaoyong; Qin, Li; Su, Qing

    2017-01-01

    It is reported that total white blood cell is associated with risk of diabetes mellitus. The present study is to investigate the relationship of white blood cell subsets with incidence of type 2 diabetes at baseline and 3year follow-up. We chose individuals without diabetes history as our study population; 8991 individuals were included at baseline. All of the participants underwent a 75-g OGTT at baseline. White blood cell count including all the subsets were measured along with all the other laboratory indices. The participants who were not diagnosed with type 2 diabetes according to the WHO 1999 diagnostic criteria underwent another 75-g OGTT at 3year follow-up. The total WBC count, neutrophil count, and lymphocyte count were significantly increased in subjects newly diagnosed with diabetes mellitus compared to non-DM subjects at baseline (all ptype 2 diabetes. Copyright © 2017 Elsevier Inc. All rights reserved.

  12. A comparison of positron-emitting blood pool imaging agents

    International Nuclear Information System (INIS)

    Hnatowich, D.J.; Kulprathipanja, S.; Evans, G.; Elmaleh, D.

    1979-01-01

    The three agents, 11 C-carboxyhaemoglobin, 68 Ga-transferrin and 68 Ga-labelled red cells have been compared in dogs to assess their relative merits for blood-pool imaging. For 1 h following administration of each agent, periodic blood samples were withdrawn for counting in a NaI (Tl) well counter while conventional two-dimensional images were obtained simultaneously on the Massachusetts General Hospital positron camera. Count rates in regions about the heart, liver and spleen were obtained for each image. The disappearance of blood activity as shown from the results of counting the blood samples and from the counting rates in regions about the heart was found to be identical within experimental error for the three agents. In the liver and spleen regions, the highest count rates were obtained with 68 Ga-transferrin and the lowest with 68 Ga-labelled red cells; count rates in these regions with labelled red cells were virtually constant throughout the 1 h study. It may be concluded that with the exceptions noted above, the three agents are approximately equivalent for blood-pool imaging. (author)

  13. More accurate thermal neutron coincidence counting technique

    International Nuclear Information System (INIS)

    Baron, N.

    1978-01-01

    Using passive thermal neutron coincidence counting techniques, the accuracy of nondestructive assays of fertile material can be improved significantly using a two-ring detector. It was shown how the use of a function of the coincidence count rate ring-ratio can provide a detector response rate that is independent of variations in neutron detection efficiency caused by varying sample moderation. Furthermore, the correction for multiplication caused by SF- and (α,n)-neutrons is shown to be separable into the product of a function of the effective mass of 240 Pu (plutonium correction) and a function of the (α,n) reaction probability (matrix correction). The matrix correction is described by a function of the singles count rate ring-ratio. This correction factor is empirically observed to be identical for any combination of PuO 2 powder and matrix materials SiO 2 and MgO because of the similar relation of the (α,n)-Q value and (α,n)-reaction cross section among these matrix nuclei. However the matrix correction expression is expected to be different for matrix materials such as Na, Al, and/or Li. Nevertheless, it should be recognized that for comparison measurements among samples of similar matrix content, it is expected that some function of the singles count rate ring-ratio can be defined to account for variations in the matrix correction due to differences in the intimacy of mixture among the samples. Furthermore the magnitude of this singles count rate ring-ratio serves to identify the contaminant generating the (α,n)-neutrons. Such information is useful in process control

  14. Project and construction of counting system for neutron probe

    International Nuclear Information System (INIS)

    Monteiro, W.P.

    1985-01-01

    A counting system was developed for coupling neutron probe aiming to register pulses produced by slow neutron interaction in the detector. The neutron probe consists of fast neutron source, thermal neutron detector, amplifier circuit and pulse counting circuit. The counting system is composed by counting circuit, timer and signal circuit. (M.C.K.)

  15. Correlation between total lymphocyte count, hemoglobin, hematocrit and CD4 count in HIV patients in Nigeria.

    Science.gov (United States)

    Emuchay, Charles Iheanyichi; Okeniyi, Shemaiah Olufemi; Okeniyi, Joshua Olusegun

    2014-04-01

    The expensive and technology limited setting of CD4 count testing is a major setback to the initiation of HAART in a resource limited country like Nigeria. Simple and inexpensive tools such as Hemoglobin (Hb) measurement and Total Lymphocyte Count (TLC) are recommended as substitute marker. In order to assess the correlations of these parameters with CD4 count, 100 "apparently healthy" male volunteers tested HIV positive aged ≥ 20 years but ≤ 40 years were recruited and from whom Hb, Hct, TLC and CD4 count were obtained. The correlation coefficients, R, the Nash-Sutcliffe Coefficient of Efficiency (CoE) and the p-values of the ANOVA model of Hb, Hct and TLC with CD4 count were assessed. The assessments show that there is no significant relationship of any of these parameters with CD4 count and the correlation coefficients are very weak. This study shows that Hb, Hct and TLC cannot be substitute for CD4 count as this might lead to certain individuals' deprivation of required treatment.

  16. Managing your blood sugar

    Science.gov (United States)

    Hyperglycemia - control; Hypoglycemia - control; Diabetes - blood sugar control; Blood glucose - managing ... sugar ( hypoglycemia ) Recognize and treat high blood sugar ( hyperglycemia ) Plan healthy meals Monitor your blood sugar (glucose) ...

  17. Hip Synovial Fluid Cell Counts in Children From a Lyme Disease Endemic Area.

    Science.gov (United States)

    Dart, Arianna H; Michelson, Kenneth A; Aronson, Paul L; Garro, Aris C; Lee, Thomas J; Glerum, Kimberly M; Nigrovic, Peter A; Kocher, Mininder S; Bachur, Richard G; Nigrovic, Lise E

    2018-05-01

    Patients with septic hip arthritis require surgical drainage, but they can be difficult to distinguish from patients with Lyme arthritis. The ability of synovial fluid white blood cell (WBC) counts to help discriminate between septic and Lyme arthritis of the hip has not been investigated. We assembled a retrospective cohort of patients ≤21 years of age with hip monoarticular arthritis and a synovial fluid culture obtained who presented to 1 of 3 emergency departments located in Lyme disease endemic areas. Septic arthritis was defined as a positive synovial fluid culture result or synovial fluid pleocytosis (WBC count ≥50 000 cells per µL) with a positive blood culture result. Lyme arthritis was defined as positive 2-tiered Lyme disease serology results and negative synovial fluid bacterial culture results. All other patients were classified as having other arthritis. We compared median synovial fluid WBC counts by arthritis type. Of the 238 eligible patients, 26 (11%) had septic arthritis, 32 (13%) had Lyme arthritis, and 180 (76%) had other arthritis. Patients with septic arthritis had a higher median synovial fluid WBC count (126 130 cells per µL; interquartile range 83 303-209 332 cells per µL) than patients with Lyme arthritis (53 955 cells per µL; interquartile range 33 789-73 375 cells per µL). Eighteen patients (56%) with Lyme arthritis had synovial fluid WBC counts ≥50 000 cells per µL. Of the 94 patients who underwent surgical drainage, 13 were later diagnosed with Lyme arthritis. In Lyme disease endemic areas, synovial fluid WBC counts cannot always help differentiate septic from Lyme arthritis. Rapid Lyme diagnostics could help avoid unnecessary operative procedures in patients with Lyme arthritis. Copyright © 2018 by the American Academy of Pediatrics.

  18. A counting-card circuit based on PCI bus

    International Nuclear Information System (INIS)

    Shi Jing; Li Yong; Chinese Academy of Sciences, Lanzhou; Su Hong; Dong Chengfu; Li Xiaogang; Ma Xiaoli

    2004-01-01

    A counting-card circuit based on PCI bus that we developed recently used for advanced personal computer will be introduced in this paper briefly. The maximum count capacity of this counting-card is 10 9 -1, ranging from 0 to 999 999 999, the maximum counting time range, 1 x 10 6 s, can be set in 1 cycle, the maximum counting rate is 20 MHz for positive input. (authors)

  19. TasselNet: counting maize tassels in the wild via local counts regression network.

    Science.gov (United States)

    Lu, Hao; Cao, Zhiguo; Xiao, Yang; Zhuang, Bohan; Shen, Chunhua

    2017-01-01

    Accurately counting maize tassels is important for monitoring the growth status of maize plants. This tedious task, however, is still mainly done by manual efforts. In the context of modern plant phenotyping, automating this task is required to meet the need of large-scale analysis of genotype and phenotype. In recent years, computer vision technologies have experienced a significant breakthrough due to the emergence of large-scale datasets and increased computational resources. Naturally image-based approaches have also received much attention in plant-related studies. Yet a fact is that most image-based systems for plant phenotyping are deployed under controlled laboratory environment. When transferring the application scenario to unconstrained in-field conditions, intrinsic and extrinsic variations in the wild pose great challenges for accurate counting of maize tassels, which goes beyond the ability of conventional image processing techniques. This calls for further robust computer vision approaches to address in-field variations. This paper studies the in-field counting problem of maize tassels. To our knowledge, this is the first time that a plant-related counting problem is considered using computer vision technologies under unconstrained field-based environment. With 361 field images collected in four experimental fields across China between 2010 and 2015 and corresponding manually-labelled dotted annotations, a novel Maize Tassels Counting ( MTC ) dataset is created and will be released with this paper. To alleviate the in-field challenges, a deep convolutional neural network-based approach termed TasselNet is proposed. TasselNet can achieve good adaptability to in-field variations via modelling the local visual characteristics of field images and regressing the local counts of maize tassels. Extensive results on the MTC dataset demonstrate that TasselNet outperforms other state-of-the-art approaches by large margins and achieves the overall best counting

  20. TasselNet: counting maize tassels in the wild via local counts regression network

    Directory of Open Access Journals (Sweden)

    Hao Lu

    2017-11-01

    Full Text Available Abstract Background Accurately counting maize tassels is important for monitoring the growth status of maize plants. This tedious task, however, is still mainly done by manual efforts. In the context of modern plant phenotyping, automating this task is required to meet the need of large-scale analysis of genotype and phenotype. In recent years, computer vision technologies have experienced a significant breakthrough due to the emergence of large-scale datasets and increased computational resources. Naturally image-based approaches have also received much attention in plant-related studies. Yet a fact is that most image-based systems for plant phenotyping are deployed under controlled laboratory environment. When transferring the application scenario to unconstrained in-field conditions, intrinsic and extrinsic variations in the wild pose great challenges for accurate counting of maize tassels, which goes beyond the ability of conventional image processing techniques. This calls for further robust computer vision approaches to address in-field variations. Results This paper studies the in-field counting problem of maize tassels. To our knowledge, this is the first time that a plant-related counting problem is considered using computer vision technologies under unconstrained field-based environment. With 361 field images collected in four experimental fields across China between 2010 and 2015 and corresponding manually-labelled dotted annotations, a novel Maize Tassels Counting (MTC dataset is created and will be released with this paper. To alleviate the in-field challenges, a deep convolutional neural network-based approach termed TasselNet is proposed. TasselNet can achieve good adaptability to in-field variations via modelling the local visual characteristics of field images and regressing the local counts of maize tassels. Extensive results on the MTC dataset demonstrate that TasselNet outperforms other state-of-the-art approaches by large

  1. Double hard scattering without double counting

    Energy Technology Data Exchange (ETDEWEB)

    Diehl, Markus [Deutsches Elektronen-Synchrotron (DESY), Hamburg (Germany); Gaunt, Jonathan R. [VU Univ. Amsterdam (Netherlands). NIKHEF Theory Group; Schoenwald, Kay [Deutsches Elektronen-Synchrotron (DESY), Zeuthen (Germany)

    2017-02-15

    Double parton scattering in proton-proton collisions includes kinematic regions in which two partons inside a proton originate from the perturbative splitting of a single parton. This leads to a double counting problem between single and double hard scattering. We present a solution to this problem, which allows for the definition of double parton distributions as operator matrix elements in a proton, and which can be used at higher orders in perturbation theory. We show how the evaluation of double hard scattering in this framework can provide a rough estimate for the size of the higher-order contributions to single hard scattering that are affected by double counting. In a numeric study, we identify situations in which these higher-order contributions must be explicitly calculated and included if one wants to attain an accuracy at which double hard scattering becomes relevant, and other situations where such contributions may be neglected.

  2. Process to Obtain Quick Counts from PREP

    Directory of Open Access Journals (Sweden)

    Martínez–Cruz M.Á.

    2011-10-01

    Full Text Available Considering the Preliminary Electoral Results Program (PERP as a database of the federal elections for president of the Mexican Republic, a methodology was developed in order to find representative samples of ballot boxes installed in the election’s day (quick count in different hours, due to its characteristics of gathering of information, the PREP in the first hours forms a non-representative sample of data. In a particular way, in the election of July 2, 2006, after 3 hours of opening the PREP, it was observed that the accuracy of the process of the quick counts was better than the one obtained by the IFE. Among other things, this allows to lower the cost, to increase the confidentiality of the ballot boxes used in the sampling and to distinguish in a precise moment the winning candidate long before PREP finishes.

  3. Frontal subregions mediating Elevator Counting task performance.

    Science.gov (United States)

    MacPherson, Sarah E; Turner, Martha S; Bozzali, Marco; Cipolotti, Lisa; Shallice, Tim

    2010-10-01

    Deficits in sustained attention may lead to action slips in everyday life as irrelevant action sequences are inappropriately triggered internally or by the environment. While deficits in sustained attention have been associated with damage to the frontal lobes of the brain, little is known about the role of the frontal lobes in the Elevator Counting subtest of the Test of Everyday Attention. In the current study, 55 frontal patients subdivided into medial, orbital and lateral subgroups, 18 patients with posterior lesions and 82 healthy controls performed the Elevator Counting task. The results revealed that patients with medial and left lateral prefrontal lesions were significantly impaired on the task compared to healthy controls. Research suggests that patients with medial lesions are susceptible to competition from task irrelevant schema; whereas the left lateral group in the current study may fail to keep track of the tones already presented. Copyright © 2010 Elsevier Ltd. All rights reserved.

  4. How fast can quantum annealers count?

    International Nuclear Information System (INIS)

    Hen, Itay

    2014-01-01

    We outline an algorithm for the quantum counting problem using adiabatic quantum computation (AQC). We show that the mechanism of quantum-adiabatic evolution may be utilized toward estimating the number of solutions to a problem, and not only to find them. Using local adiabatic evolution, a process in which the adiabatic procedure is performed at a variable rate, the problem of counting the number of marked items in an unstructured database is solved quadratically faster than the corresponding classical algorithm. The above algorithm provides further evidence for the potentially powerful capabilities of AQC as a paradigm for more efficient problem solving on a quantum computer, and may be used as the basis for solving more sophisticated problems. (paper)

  5. Scintillation counting: an extrapolation into the future

    International Nuclear Information System (INIS)

    Ross, H.H.

    1983-01-01

    Progress in scintillation counting is intimately related to advances in a variety of other disciplines such as photochemistry, photophysics, and instrumentation. And while there is steady progress in the understanding of luminescent phenomena, there is a virtual explosion in the application of semiconductor technology to detectors, counting systems, and data processing. The exponential growth of this technology has had, and will continue to have, a profound effect on the art of scintillation spectroscopy. This paper will review key events in technology that have had an impact on the development of scintillation science (solid and liquid) and will attempt to extrapolate future directions based on existing and projected capability in associated fields. Along the way there have been occasional pitfalls and several false starts; these too will be discussed as a reminder that if you want the future to be different than the past, study the past

  6. Going Online to Make Learning Count

    Directory of Open Access Journals (Sweden)

    Cathy Brigham

    2011-01-01

    Full Text Available Adult students often come to higher education with college-level learning that they have acquired outside of the classroom – from the workplace, military service, self-study, or hobbies. For decades, many forward-thinking colleges and universities have been offering services to evaluate that learning and award it college credit that counts towards a degree. However, for a range of reasons, not every institution can offer prior learning assessment (PLA in every discipline or for every student. With funding from several U.S. philanthropic organizations, the Council for Adult and Experiential Learning (CAEL is launching Learning Counts, a national online service that will offer students a range of opportunities to have their learning evaluated for college credit. This online service will expand the capacity of institutions offering PLA to students and provide an efficient and scalable delivery mechanism for the awarding of credit through PLA.

  7. Liquid scintillation counting analysis of cadmium-109

    International Nuclear Information System (INIS)

    Robinson, M.K.; Barfuss, D.W.

    1991-01-01

    Recently the authors have used radiolabled cadmium-109 to measure the transport of inorganic cadmium in renal proximal tubules. An anomaly discovered in the liquid scintillation counting analysis of Cd-109 which is not attributable to normal decay; it consists of a significant decrease in the measured count rate of small amounts of sample. The objective is to determine whether the buffer solution used in the membrane transport studies is causing precipitation of the cadmium or whether cadmium is being adsorbed by the glass. It was important to determine whether the procedure could be modified to correct this problem. The problem does not appear to be related to the use of the buffer or to adsorption of Cd onto glass. Correction based on using triated L-glucose in all of these experiments and calculating a correction factor for the concentration of cadmium

  8. Double hard scattering without double counting

    International Nuclear Information System (INIS)

    Diehl, Markus; Gaunt, Jonathan R.

    2017-02-01

    Double parton scattering in proton-proton collisions includes kinematic regions in which two partons inside a proton originate from the perturbative splitting of a single parton. This leads to a double counting problem between single and double hard scattering. We present a solution to this problem, which allows for the definition of double parton distributions as operator matrix elements in a proton, and which can be used at higher orders in perturbation theory. We show how the evaluation of double hard scattering in this framework can provide a rough estimate for the size of the higher-order contributions to single hard scattering that are affected by double counting. In a numeric study, we identify situations in which these higher-order contributions must be explicitly calculated and included if one wants to attain an accuracy at which double hard scattering becomes relevant, and other situations where such contributions may be neglected.

  9. Recent progress with digital coincidence counting

    International Nuclear Information System (INIS)

    Butcher, K.S.A.; Watt, G.C.; Alexiev, D.

    1999-01-01

    Digital Coincidence Counting (DCC) is a new technique, based on the older method of analogue coincidence counting. It has been developed by ANSTO as a faster more reliable means of determining the activity of ionising radiation samples. The technique employs a dual channel analogue to digital converter acquisition system for collecting pulse information from a 4Π beta detector and a NaI(Tl) gamma detector. The digitised pulse information is stored on a high speed hard disk and timing information for both channels is also stored. The data may subsequently be recalled and analysed using software based algorithms. The system is operational and results are now being routinely collected and analysed. Some of the early work is presented for Co-60, Na-22 and Sm-153

  10. Agreement of manual cell counts and automated counts of the scil Vet abc Plus(+) hematology analyzer for analysis of equine synovial fluid.

    Science.gov (United States)

    Van de Water, Eline; Oosterlinck, Maarten; Duchateau, Luc; Pille, Frederik

    2016-06-01

    The purpose of this study was to determine whether the scil Vet abc Plus(+) (SCIL Animal Care Company, Altorf, France), an impedance hematology analyzer, can accurately quantify and differentiate nucleated blood cells (NBCs) in equine synovial fluid. Synovial fluid samples (n=242) in different stages of experimentally induced inflammation were analyzed with and without hyaluronidase pretreatment and compared to manual hemocytometer counts and smear reviews. No significant effect of hyaluronidase pretreatment was observed. Total nucleated cell counts of the scil Vet abc Plus(+) were significantly higher compared to the manual method (P=0.02), yet the difference was small and clinically irrelevant (ratio manual/automated count equal to 0.97 with 95% CI [0.95, 1.00]). Differential cell counts of the scil Vet abc Plus(+) were not accurate. In conclusion, the scil Vet abc Plus(+) hematology analyzer is highly accurate for quantification, but not accurate for differentiation of NBCs in equine synovial fluid. Copyright © 2016 Elsevier Ltd. All rights reserved.

  11. Inventory verification measurements using neutron multiplicity counting

    International Nuclear Information System (INIS)

    Ensslin, N.; Foster, L.A.; Harker, W.C.; Krick, M.S.; Langner, D.G.

    1998-01-01

    This paper describes a series of neutron multiplicity measurements of large plutonium samples at the Los Alamos Plutonium Facility. The measurements were corrected for bias caused by neutron energy spectrum shifts and nonuniform multiplication, and are compared with calorimetry/isotopics. The results show that multiplicity counting can increase measurement throughput and yield good verification results for some inventory categories. The authors provide recommendations on the future application of the technique to inventory verification

  12. Counting graphene layers with very slow electrons

    Czech Academy of Sciences Publication Activity Database

    Frank, Luděk; Mikmeková, Eliška; Müllerová, Ilona; Lejeune, M.

    2015-01-01

    Roč. 106, 09 JAN (2015), 013117:1-5 ISSN 0003-6951 R&D Projects: GA TA ČR(CZ) TE01020118; GA MŠk(CZ) LO1212 Institutional support: RVO:68081731 Keywords : graphene * ultralow energy STEM * counting graphene layers * clean ing of graphene * 2D crystals Subject RIV: JA - Electronics ; Optoelectronics, Electrical Engineering Impact factor: 3.142, year: 2015

  13. Optimal Planar Orthogonal Skyline Counting Queries

    DEFF Research Database (Denmark)

    Brodal, Gerth Stølting; Larsen, Kasper Green

    2014-01-01

    counting queries, i.e. given a query rectangle R to report the size of the skyline of P\\cap R. We present a data structure for storing n points with integer coordinates having query time O(lg n/lglg n) and space usage O(n). The model of computation is a unit cost RAM with logarithmic word size. We prove...

  14. Total bacterial count and somatic cell count in refrigerated raw milk stored in communal tanks

    Directory of Open Access Journals (Sweden)

    Edmar da Costa Alves

    2014-09-01

    Full Text Available The current industry demand for dairy products with extended shelf life has resulted in new challenges for milk quality maintenance. The processing of milk with high bacterial counts compromises the quality and performance of industrial products. The study aimed to evaluate the total bacteria counts (TBC and somatic cell count (SCC in 768 samples of refrigerated raw milk, from 32 communal tanks. Samples were collected in the first quarter of 2010, 2011, 2012 and 2013 and analyzed by the Laboratory of Milk Quality - LQL. Results showed that 62.5%, 37.5%, 15.6% and 27.1% of the means for TBC in 2010, 2011, 2012 and 2013, respectively, were above the values established by legislation. However, we observed a significant reduction in the levels of total bacterial count (TBC in the studied periods. For somatic cell count, 100% of the means indicated values below 600.000 cells/mL, complying with the actual Brazilian legislation. The values found for the somatic cell count suggests the adoption of effective measures for the sanitary control of the herd. However, the results must be considered with caution as it highlights the need for quality improvements of the raw material until it achieves reliable results effectively.

  15. Bayesian analysis of energy and count rate data for detection of low count rate radioactive sources.

    Science.gov (United States)

    Klumpp, John; Brandl, Alexander

    2015-03-01

    A particle counting and detection system is proposed that searches for elevated count rates in multiple energy regions simultaneously. The system analyzes time-interval data (e.g., time between counts), as this was shown to be a more sensitive technique for detecting low count rate sources compared to analyzing counts per unit interval (Luo et al. 2013). Two distinct versions of the detection system are developed. The first is intended for situations in which the sample is fixed and can be measured for an unlimited amount of time. The second version is intended to detect sources that are physically moving relative to the detector, such as a truck moving past a fixed roadside detector or a waste storage facility under an airplane. In both cases, the detection system is expected to be active indefinitely; i.e., it is an online detection system. Both versions of the multi-energy detection systems are compared to their respective gross count rate detection systems in terms of Type I and Type II error rates and sensitivity.

  16. Blood Tests

    Science.gov (United States)

    ... of your immune system, which fights infections and diseases. Abnormal white blood cell levels may be a sign ... fall outside the normal range for many reasons. Abnormal results might be a sign of a disorder or disease. Other factors—such as diet, menstrual ...

  17. Monitoring of benzene-induced hematotoxicity in mice by serial leukocyte counting using a microcavity array.

    Science.gov (United States)

    Hosokawa, Masahito; Asami, Marie; Yoshino, Tomoko; Tsujimura, Noriyuki; Takahashi, Masayuki; Nakasono, Satoshi; Tanaka, Tsuyoshi; Matsunaga, Tadashi

    2013-02-15

    Monitoring of hematotoxicity, which requires serial blood collection, is difficult to carry out in small animals due to a lack of non-invasive, individual animal-appropriate techniques that enable enumeration of leukocyte subsets from limited amounts of whole blood. In this study, a microfluidic device equipped with a microcavity array that enables highly efficient separation of leukocytes from submicroliters of whole blood was applied for hematotoxicity monitoring in mice. The microcavity array can specifically separate leukocytes from whole blood based on differences in the size and deformability between leukocytes and other blood cells. Mouse leukocytes recovered on aligned microcavities were continuously processed for image-based immunophenotypic analysis. Our device successfully recovered almost 100% of mouse leukocytes in 0.1 μL of whole blood without the effect of serial blood collection such as changes in body weight and total leukocyte count. We assessed benzene-associated hematotoxicity in mice using this system. Mice were administered with benzene once daily and the depression of leukocyte numbers induced in individual mice was successfully monitored from tail vein blood collected every other day for 2 weeks. Serial monitoring of the leukocyte number in individual mice will contribute to the understanding of hematotoxicity and reduction of the number of animal experiment trials. Copyright © 2012 Elsevier B.V. All rights reserved.

  18. Evaluation of plasma eosinophil count and mean platelet volume in patients with coronary slow flow

    Directory of Open Access Journals (Sweden)

    Mehmet Demir

    2014-01-01

    Full Text Available OBJECTIVE: The pathophysiology of coronary slow flow has not been clearly defined, although multiple abnormalities including arteritis, endothelial dysfunction, and atherothrombosis, have been reported. It is known that eosinophils play an important role in inflammation, endothelial dysfunction, and thrombosis. We aimed to compare the eosinophil counts of coronary slow flow patients versus healthy controls. METHODS: This study included 50 coronary slow flow patients (19 males, mean age 65.6±13.7 years and 30 healthy controls (10 males, mean age 57.86±11.6 years. These participants were evaluated using concurrent routine biochemical tests as well as neutrophil, lymphocyte, and eosinophil counts and mean platelet volume (MPV, which were obtained from the whole blood count. These parameters were compared between groups. RESULTS: The baseline characteristics of the study groups were comparable. The coronary slow flow patients had a higher mean platelet volume and eosinophil count than the control group (8.38±0.86 vs 6.28±1.6 fL and 0.31±0.42 vs 0.09±0.05; p<0.001 and 0.008, respectively. CONCLUSION: Our study demonstrated a relationship between eosinophil count and MPV in patients with coronary slow flow.

  19. Metal ion levels and lymphocyte counts

    DEFF Research Database (Denmark)

    Penny, Jeannette Ø; Varmarken, Jens-Erik; Ovesen, Ole

    2013-01-01

    BACKGROUND AND PURPOSE: Wear particles from metal-on-metal arthroplasties are under suspicion for adverse effects both locally and systemically, and the DePuy ASR Hip Resurfacing System (RHA) has above-average failure rates. We compared lymphocyte counts in RHA and total hip arthroplasty (THA) an....../ppb. INTERPRETATION: Circulating T-lymphocyte levels may decline after surgery, regardless of implant type. Metal ions-particularly cobalt-may have a general depressive effect on T- and B-lymphocyte levels. Registered with ClinicalTrials.gov under # NCT01113762.......BACKGROUND AND PURPOSE: Wear particles from metal-on-metal arthroplasties are under suspicion for adverse effects both locally and systemically, and the DePuy ASR Hip Resurfacing System (RHA) has above-average failure rates. We compared lymphocyte counts in RHA and total hip arthroplasty (THA....... RESULTS: The T-lymphocyte counts for both implant types declined over the 2-year period. This decline was statistically significant for CD3(+)CD8(+) in the THA group, with a regression coefficient of -0.04 × 10(9)cells/year (95% CI: -0.08 to -0.01). Regression analysis indicated a depressive effect...

  20. Accuracy in activation analysis: count rate effects

    International Nuclear Information System (INIS)

    Lindstrom, R.M.; Fleming, R.F.

    1980-01-01

    The accuracy inherent in activation analysis is ultimately limited by the uncertainty of counting statistics. When careful attention is paid to detail, several workers have shown that all systematic errors can be reduced to an insignificant fraction of the total uncertainty, even when the statistical limit is well below one percent. A matter of particular importance is the reduction of errors due to high counting rate. The loss of counts due to random coincidence (pulse pileup) in the amplifier and to digitization time in the ADC may be treated as a series combination of extending and non-extending dead times, respectively. The two effects are experimentally distinct. Live timer circuits in commercial multi-channel analyzers compensate properly for ADC dead time for long-lived sources, but not for pileup. Several satisfactory solutions are available, including pileup rejection and dead time correction circuits, loss-free ADCs, and computed corrections in a calibrated system. These methods are sufficiently reliable and well understood that a decaying source can be measured routinely with acceptably small errors at a dead time as high as 20 percent