WorldWideScience

Sample records for blood concentration measurements

  1. Correlation between glucose concentrations in serum, plasma, and whole blood measured by a point-of-care glucometer and serum glucose concentration measured by an automated biochemical analyzer for canine and feline blood samples.

    Science.gov (United States)

    Tauk, Barbara S; Drobatz, Kenneth J; Wallace, Koranda A; Hess, Rebecka S

    2015-06-15

    To investigate the correlation between glucose concentrations in serum, plasma, and whole blood measured by a point-of-care glucometer (POCG) and serum glucose concentration measured by a biochemical analyzer. Prospective clinical study. 96 blood samples from 80 dogs and 90 blood samples from 65 cats. Serum, plasma, and whole blood were obtained from each blood sample. The glucose concentrations in serum, plasma, and whole blood measured by a POCG were compared with the serum glucose concentration measured by a biochemical analyzer by use of the Lin concordance correlation coefficient (ρc) and Bland-Altman plots. For both canine and feline samples, glucose concentrations in serum and plasma measured by the POCG were more strongly correlated with the serum glucose concentration measured by the biochemical analyzer (ρc, 0.98 for both canine serum and plasma; ρc, 0.99 for both feline serum and plasma) than was that in whole blood (ρc, 0.62 for canine samples; ρc, 0.90 for feline samples). The mean difference between the glucose concentrations determined by the biochemical analyzer and the POCG in serum, plasma, and whole blood was 0.4, 0.3, and 31 mg/dL, respectively, for canine samples and 7, 6, and 32 mg/dL, respectively, for feline samples. Results indicated that use of a POCG to measure glucose concentrations in serum or plasma may increase the accuracy and reliability of diagnostic and treatment decisions associated with glucose homeostasis disorders in dogs and cats.

  2. Comparison of spectroscopically measured tissue alcohol concentration to blood and breath alcohol measurements

    Science.gov (United States)

    Ridder, Trent D.; Ver Steeg, Benjamin J.; Laaksonen, Bentley D.

    2009-09-01

    Alcohol testing is an expanding area of interest due to the impacts of alcohol abuse that extend well beyond drunk driving. However, existing approaches such as blood and urine assays are hampered in some testing environments by biohazard risks. A noninvasive, in vivo spectroscopic technique offers a promising alternative, as no body fluids are required. The purpose of this work is to report the results of a 36-subject clinical study designed to characterize tissue alcohol measured using near-infrared spectroscopy relative to venous blood, capillary blood, and breath alcohol. Comparison of blood and breath alcohol concentrations demonstrated significant differences in alcohol concentration [root mean square of 9.0 to 13.5 mg/dL] that were attributable to both assay accuracy and precision as well as alcohol pharmacokinetics. A first-order kinetic model was used to estimate the contribution of alcohol pharmacokinetics to the differences in concentration observed between the blood, breath, and tissue assays. All pair-wise combinations of alcohol assays were investigated, and the fraction of the alcohol concentration variance explained by pharmacokinetics ranged from 41.0% to 83.5%. Accounting for pharmacokinetic concentration differences, the accuracy and precision of the spectroscopic tissue assay were found to be comparable to those of the blood and breath assays.

  3. Prompt gamma-ray spectrometry for measurement of B-10 concentration in brain tissue and blood

    International Nuclear Information System (INIS)

    Nakagawa, Yoshinobu; Kitamura, Katsuji; Kobayashi, Toru; Matsumoto, Keizo; Hatanaka, Hiroshi.

    1993-01-01

    Boron-10 (B-10) concentration in the brain tissue and blood was measured continuously for 24 hours after injection of the B-10 compound in live rabbits using prompt gamma-ray spectrometry. Following injection of B-10 compound (Na 2 B 12 H 11 SH, 50mg/kg) dissolved in physiological saline, B-10 concentration was continuously measured in the brain tissue. Intermittently the concentration of B-10 in blood and cerebro-spinal fluid (CSF) was also measured. In 10 minutes after the injection of B-10 compound, the level of B-10 concentration reached the peak of 400-500 ppm in blood and 20-30 ppm in the normal brain tissue. In 60 minutes the level of B-10 concentration rapidly decreased and then a gradual decline was observed. The value was 15-30 ppm at 3 hours after injection, 5-10 ppm at 6 hours and 2-5 ppm at 24 hours in the blood. The concentration in the brain tissue was 3-8 ppm at 3 hours, 2-5 ppm at 6 hours and below 1.5 ppm at 24 hours. B-10 concentration in cerebro-spinal fluid was below 1 ppm. B-10 concentration was also measured in the brain tumor and blood in the human cases at boron neutron capture therapy (BNCT). These data studied by prompt gamma-ray spectrometry are very important and useful to decide the irradiation time. (author)

  4. Study on the mechanism of human blood glucose concentration measuring using mid-infrared spectral analysis technology

    Science.gov (United States)

    Li, Xiang

    2016-10-01

    All forms of diabetes increase the risk of long-term complications. Blood glucose monitoring is of great importance for controlling diabetes procedure, preventing the complications and improving the patient's life quality. At present, the clinical blood glucose concentration measurement is invasive and could be replaced by noninvasive spectroscopy analytical techniques. The mid-infrared spectral region contains strong characteristic and well-defined absorption bands. Therefore, mid-infrared provides an opportunity for monitoring blood glucose invasively with only a few discrete bonds. Although the blood glucose concentration measurement using mid-infrared spectroscopy has a lot of advantages, the disadvantage is also obvious. The absorption in this infrared region is fundamental molecular group vibration. Absorption intensity is very strong, especially for biological molecules. In this paper, it figures out that the osmosis rate of glucose has a certain relationship with the blood glucose concentration. Therefore, blood glucose concentration could be measured indirectly by measuring the glucose exudate in epidermis layer. Human oral glucose tolerance tests were carried out to verify the correlation of glucose exudation in shallow layer of epidermis layer and blood glucose concentration. As it has been explained above, the mid-infrared spectral region contains well-defined absorption bands, the intensity of absorption peak around 1123 cm-1 was selected to measure the glucose and that around 1170 cm-1 was selected as reference. Ratio of absorption peak intensity was recorded for each set of measurement. The effect and importance of the cleaning the finger to be measured before spectrum measuring are discussed and also verified by experiment.

  5. Plasma concentrations of blood coagulation factor VII measured by immunochemical and amidolytic methods

    DEFF Research Database (Denmark)

    Bladbjerg, E-M; Gram, J; Jespersen, J

    2000-01-01

    Ever since the coagulant activity of blood coagulation factor VII (FVII:C) was identified as a risk indicator of cardiac death, a large number of studies have measured FVII protein concentrations in plasma. FVII protein concentrations are either measured immunologically with an ELISA method (FVII...

  6. Quantitative spatially resolved measurement of tissue chromophore concentrations using photoacoustic spectroscopy: application to the measurement of blood oxygenation and haemoglobin concentration

    Science.gov (United States)

    Laufer, Jan; Delpy, Dave; Elwell, Clare; Beard, Paul

    2007-01-01

    A new approach based on pulsed photoacoustic spectroscopy for non-invasively quantifying tissue chromophore concentrations with high spatial resolution has been developed. The technique is applicable to the quantification of tissue chromophores such as oxyhaemoglobin (HbO2) and deoxyhaemoglobin (HHb) for the measurement of physiological parameters such as blood oxygen saturation (SO2) and total haemoglobin concentration. It can also be used to quantify the local accumulation of targeted contrast agents used in photoacoustic molecular imaging. The technique employs a model-based inversion scheme to recover the chromophore concentrations from photoacoustic measurements. This comprises a numerical forward model of the detected time-dependent photoacoustic signal that incorporates a multiwavelength diffusion-based finite element light propagation model to describe the light transport and a time-domain acoustic model to describe the generation, propagation and detection of the photoacoustic wave. The forward model is then inverted by iteratively fitting it to measurements of photoacoustic signals acquired at different wavelengths to recover the chromophore concentrations. To validate this approach, photoacoustic signals were generated in a tissue phantom using nanosecond laser pulses between 740 nm and 1040 nm. The tissue phantom comprised a suspension of intralipid, blood and a near-infrared dye in which three tubes were immersed. Blood at physiological haemoglobin concentrations and oxygen saturation levels ranging from 2% to 100% was circulated through the tubes. The signal amplitude from different temporal sections of the detected photoacoustic waveforms was plotted as a function of wavelength and the forward model fitted to these data to recover the concentrations of HbO2 and HHb, total haemoglobin concentration and SO2. The performance was found to compare favourably to that of a laboratory CO-oximeter with measurement resolutions of ±3.8 g l-1 (±58 µM) and ±4

  7. Quantitative spatially resolved measurement of tissue chromophore concentrations using photoacoustic spectroscopy: application to the measurement of blood oxygenation and haemoglobin concentration

    Energy Technology Data Exchange (ETDEWEB)

    Laufer, Jan; Delpy, Dave; Elwell, Clare; Beard, Paul [Department of Medical Physics and Bioengineering, University College London, Malet Place Engineering Building, London WC1E 6BT (United Kingdom)

    2007-01-07

    A new approach based on pulsed photoacoustic spectroscopy for non-invasively quantifying tissue chromophore concentrations with high spatial resolution has been developed. The technique is applicable to the quantification of tissue chromophores such as oxyhaemoglobin (HbO{sub 2}) and deoxyhaemoglobin (HHb) for the measurement of physiological parameters such as blood oxygen saturation (SO{sub 2}) and total haemoglobin concentration. It can also be used to quantify the local accumulation of targeted contrast agents used in photoacoustic molecular imaging. The technique employs a model-based inversion scheme to recover the chromophore concentrations from photoacoustic measurements. This comprises a numerical forward model of the detected time-dependent photoacoustic signal that incorporates a multiwavelength diffusion-based finite element light propagation model to describe the light transport and a time-domain acoustic model to describe the generation, propagation and detection of the photoacoustic wave. The forward model is then inverted by iteratively fitting it to measurements of photoacoustic signals acquired at different wavelengths to recover the chromophore concentrations. To validate this approach, photoacoustic signals were generated in a tissue phantom using nanosecond laser pulses between 740 nm and 1040 nm. The tissue phantom comprised a suspension of intralipid, blood and a near-infrared dye in which three tubes were immersed. Blood at physiological haemoglobin concentrations and oxygen saturation levels ranging from 2% to 100% was circulated through the tubes. The signal amplitude from different temporal sections of the detected photoacoustic waveforms was plotted as a function of wavelength and the forward model fitted to these data to recover the concentrations of HbO{sub 2} and HHb, total haemoglobin concentration and SO{sub 2}. The performance was found to compare favourably to that of a laboratory CO-oximeter with measurement resolutions of {+-}3

  8. Quantitative spatially resolved measurement of tissue chromophore concentrations using photoacoustic spectroscopy: application to the measurement of blood oxygenation and haemoglobin concentration

    International Nuclear Information System (INIS)

    Laufer, Jan; Delpy, Dave; Elwell, Clare; Beard, Paul

    2007-01-01

    A new approach based on pulsed photoacoustic spectroscopy for non-invasively quantifying tissue chromophore concentrations with high spatial resolution has been developed. The technique is applicable to the quantification of tissue chromophores such as oxyhaemoglobin (HbO 2 ) and deoxyhaemoglobin (HHb) for the measurement of physiological parameters such as blood oxygen saturation (SO 2 ) and total haemoglobin concentration. It can also be used to quantify the local accumulation of targeted contrast agents used in photoacoustic molecular imaging. The technique employs a model-based inversion scheme to recover the chromophore concentrations from photoacoustic measurements. This comprises a numerical forward model of the detected time-dependent photoacoustic signal that incorporates a multiwavelength diffusion-based finite element light propagation model to describe the light transport and a time-domain acoustic model to describe the generation, propagation and detection of the photoacoustic wave. The forward model is then inverted by iteratively fitting it to measurements of photoacoustic signals acquired at different wavelengths to recover the chromophore concentrations. To validate this approach, photoacoustic signals were generated in a tissue phantom using nanosecond laser pulses between 740 nm and 1040 nm. The tissue phantom comprised a suspension of intralipid, blood and a near-infrared dye in which three tubes were immersed. Blood at physiological haemoglobin concentrations and oxygen saturation levels ranging from 2% to 100% was circulated through the tubes. The signal amplitude from different temporal sections of the detected photoacoustic waveforms was plotted as a function of wavelength and the forward model fitted to these data to recover the concentrations of HbO 2 and HHb, total haemoglobin concentration and SO 2 . The performance was found to compare favourably to that of a laboratory CO-oximeter with measurement resolutions of ±3.8 g l -1 (±58

  9. Transcutaneous Measurement of Blood Analyte Concentration Using Raman Spectroscopy

    Science.gov (United States)

    Barman, Ishan; Singh, Gajendra P.; Dasari, Ramachandra R.; Feld, Michael S.

    2008-11-01

    Diabetes mellitus is a chronic disorder, affecting nearly 200 million people worldwide. Acute complications, such as hypoglycemia, cardiovascular disease and retinal damage, may occur if the disease is not adequately controlled. As diabetes has no known cure, tight control of glucose levels is critical for the prevention of such complications. Given the necessity for regular monitoring of blood glucose, development of non-invasive glucose detection devices is essential to improve the quality of life in diabetic patients. The commercially available glucose sensors measure the interstitial fluid glucose by electrochemical detection. However, these sensors have severe limitations, primarily related to their invasive nature and lack of stability. This necessitates the development of a truly non-invasive glucose detection technique. NIR Raman Spectroscopy, which combines the substantial penetration depth of NIR light with the excellent chemical specificity of Raman spectroscopy, provides an excellent tool to meet the challenges involved. Additionally, it enables simultaneous determination of multiple blood analytes. Our laboratory has pioneered the use of Raman spectroscopy for blood analytes' detection in biological media. The preliminary success of our non-invasive glucose measurements both in vitro (such as in serum and blood) and in vivo has provided the foundation for the development of feasible clinical systems. However, successful application of this technology still faces a few hurdles, highlighted by the problems of tissue luminescence and selection of appropriate reference concentration. In this article we explore possible avenues to overcome these challenges so that prospective prediction accuracy of blood analytes can be brought to clinically acceptable levels.

  10. Establishing traceability of photometric absorbance values for accurate measurements of the haemoglobin concentration in blood

    Science.gov (United States)

    Witt, K.; Wolf, H. U.; Heuck, C.; Kammel, M.; Kummrow, A.; Neukammer, J.

    2013-10-01

    Haemoglobin concentration in blood is one of the most frequently measured analytes in laboratory medicine. Reference and routine methods for the determination of the haemoglobin concentration in blood are based on the conversion of haeme, haemoglobin and haemiglobin species into uniform end products. The total haemoglobin concentration in blood is measured using the absorbance of the reaction products. Traceable absorbance measurement values on the highest metrological level are a prerequisite for the calibration and evaluation of procedures with respect to their suitability for routine measurements and their potential as reference measurement procedures. For this purpose, we describe a procedure to establish traceability of spectral absorbance measurements for the haemiglobincyanide (HiCN) method and for the alkaline haematin detergent (AHD) method. The latter is characterized by a higher stability of the reaction product. In addition, the toxic hazard of cyanide, which binds to the iron ion of the haem group and thus inhibits the oxygen transport, is avoided. Traceability is established at different wavelengths by applying total least-squares analysis to derive the conventional quantity values for the absorbance from the measured values. Extrapolation and interpolation are applied to get access to the spectral regions required to characterize the Q-absorption bands of the HiCN and AHD methods, respectively. For absorbance values between 0.3 and 1.8, the contributions of absorbance measurements to the total expanded uncertainties (95% level of confidence) of absorbance measurements range from 1% to 0.4%.

  11. Ammonia concentrations in canine whole blood, EDTA-anticoagulated whole blood, and plasma measured by use of a point-of-care ammonia meter.

    Science.gov (United States)

    Odunayo, Adesola; Tobias, Karen M; Okafor, Chika C; Flatland, Bente

    2017-11-01

    OBJECTIVE To investigate the use of canine whole blood (WB) for measurement of ammonia concentration by use of a point-of-care ammonia meter and to compare results of measuring ammonia concentrations in WB, EDTA-anticoagulated WB, and plasma. ANIMALS 40 client-owned dogs. PROCEDURES A blood sample (2 mL) was obtained from each dog. One drop of WB was immediately applied to a test strip for evaluation with an ammonia meter. The remainder of the blood sample was placed in an EDTA-containing tube, and 1 drop of EDTA-anticoagulated WB was applied to a test strip. The remaining EDTA-anticoagulated WB sample was centrifuged, and the plasma was harvested and placed on ice. One drop of plasma was applied to a test strip; the remainder of the plasma sample was transported on ice and used for ammonia measurement with a reference laboratory instrument. All samples were tested within 1 hour after sample collection. Results were evaluated to detect significant differences in ammonia concentration. RESULTS Ammonia concentrations did not differ significantly between WB and EDTA-anticoagulated WB and between plasma samples measured with the meter and reference laboratory instrument. However, median ammonia concentration was significantly higher in plasma than in WB or EDTA-anti-coagulated WB. CONCLUSIONS AND CLINICAL RELEVANCE Anticoagulant-free WB was a valid sample for measurement by use of the ammonia meter. Plasma samples had higher ammonia concentrations than did WB samples. Results for each sample type should be interpreted by use of specimen- and method-specific reference intervals.

  12. Evaluation of the agreement among three handheld blood glucose meters and a laboratory blood analyzer for measurement of blood glucose concentration in Hispaniolan Amazon parrots (Amazona ventralis).

    Science.gov (United States)

    Acierno, Mark J; Mitchell, Mark A; Schuster, Patricia J; Freeman, Diana; Sanchez-Migallon Guzman, David; Tully, Thomas N

    2009-02-01

    To determine the degree of agreement between 3 commercially available point-of-care blood glucose meters and a laboratory analyzer for measurement of blood glucose concentrations in Hispaniolan Amazon parrots (Amazona ventralis). 20 healthy adult Hispaniolan Amazon parrots. A 26-gauge needle and 3-mL syringe were used to obtain a blood sample (approx 0.5 mL) from a jugular vein of each parrot. Small volumes of blood (0.6 to 1.5 microL) were used to operate each of the blood glucose meters, and the remainder was placed into lithium heparin microtubes and centrifuged. Plasma was harvested and frozen at -30 degrees C. Within 5 days after collection, plasma samples were thawed and plasma glucose concentrations were measured by means of the laboratory analyzer. Agreement between pairs of blood glucose meters and between each blood glucose meter and the laboratory analyzer was evaluated by means of the Bland-Altman method, and limits of agreement (LOA) were calculated. None of the results of the 3 blood glucose meters agreed with results of the laboratory analyzer. Each point-of-care blood glucose meter underestimated the blood glucose concentration, and the degree of negative bias was not consistent (meter A bias, -94.9 mg/dL [LOA, -148.0 to -41.7 mg/dL]; meter B bias, -52 mg/dL [LOA, -107.5 to 3.5 mg/dL]; and meter C bias, -78.9 mg/dL [LOA, -137.2 to -20.6 mg/dL]). On the basis of these results, use of handheld blood glucose meters in the diagnosis or treatment of Hispaniolan Amazon parrots and other psittacines cannot be recommended.

  13. Measuring Blood Glucose Concentrations in Photometric Glucometers Requiring Very Small Sample Volumes.

    Science.gov (United States)

    Demitri, Nevine; Zoubir, Abdelhak M

    2017-01-01

    Glucometers present an important self-monitoring tool for diabetes patients and, therefore, must exhibit high accuracy as well as good usability features. Based on an invasive photometric measurement principle that drastically reduces the volume of the blood sample needed from the patient, we present a framework that is capable of dealing with small blood samples, while maintaining the required accuracy. The framework consists of two major parts: 1) image segmentation; and 2) convergence detection. Step 1 is based on iterative mode-seeking methods to estimate the intensity value of the region of interest. We present several variations of these methods and give theoretical proofs of their convergence. Our approach is able to deal with changes in the number and position of clusters without any prior knowledge. Furthermore, we propose a method based on sparse approximation to decrease the computational load, while maintaining accuracy. Step 2 is achieved by employing temporal tracking and prediction, herewith decreasing the measurement time, and, thus, improving usability. Our framework is tested on several real datasets with different characteristics. We show that we are able to estimate the underlying glucose concentration from much smaller blood samples than is currently state of the art with sufficient accuracy according to the most recent ISO standards and reduce measurement time significantly compared to state-of-the-art methods.

  14. Different top-down approaches to estimate measurement uncertainty of whole blood tacrolimus mass concentration values.

    Science.gov (United States)

    Rigo-Bonnin, Raül; Blanco-Font, Aurora; Canalias, Francesca

    2018-05-08

    Values of mass concentration of tacrolimus in whole blood are commonly used by the clinicians for monitoring the status of a transplant patient and for checking whether the administered dose of tacrolimus is effective. So, clinical laboratories must provide results as accurately as possible. Measurement uncertainty can allow ensuring reliability of these results. The aim of this study was to estimate measurement uncertainty of whole blood mass concentration tacrolimus values obtained by UHPLC-MS/MS using two top-down approaches: the single laboratory validation approach and the proficiency testing approach. For the single laboratory validation approach, we estimated the uncertainties associated to the intermediate imprecision (using long-term internal quality control data) and the bias (utilizing a certified reference material). Next, we combined them together with the uncertainties related to the calibrators-assigned values to obtain a combined uncertainty for, finally, to calculate the expanded uncertainty. For the proficiency testing approach, the uncertainty was estimated in a similar way that the single laboratory validation approach but considering data from internal and external quality control schemes to estimate the uncertainty related to the bias. The estimated expanded uncertainty for single laboratory validation, proficiency testing using internal and external quality control schemes were 11.8%, 13.2%, and 13.0%, respectively. After performing the two top-down approaches, we observed that their uncertainty results were quite similar. This fact would confirm that either two approaches could be used to estimate the measurement uncertainty of whole blood mass concentration tacrolimus values in clinical laboratories. Copyright © 2018 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  15. Comparison of a Point-of-Care Glucometer and a Laboratory Autoanalyzer for Measurement of Blood Glucose Concentrations in Domestic Pigeons ( Columba livia domestica).

    Science.gov (United States)

    Mohsenzadeh, Mahdieh Sadat; Zaeemi, Mahdieh; Razmyar, Jamshid; Azizzadeh, Mohammad

    2015-09-01

    Biochemical analysis is necessary for diagnosis and monitoring of diseases in birds; however, the small volume of blood that can be safely obtained from small avian species often limits laboratory diagnostic testing. Consequently, a suitable methodology requiring only a small volume of blood must be used. This study was designed to compare blood glucose concentrations in domestic pigeons ( Columba livia domestica) as measured by a commercial, handheld, human glucometer and a standard autoanalyzer. During the first phase of the study, whole blood samples obtained from 30 domestic pigeons were used to measure the blood glucose concentration with a glucometer, the packed cell volume (PCV), and the total erythrocyte count (nRBC). Plasma separated from the each sample was then used to obtain the plasma glucose concentration with the autoanalyzer. During the second phase of the study, 30 pigeons were assigned to 2 equal groups (n = 15). Hypoglycemia or hyperglycemia was induced in each group by intravenous injection of insulin or glucose, respectively. Blood was collected and processed, and glucose concentrations, PCV, and nRBC were measured as previously described. Linear-regression models demonstrated a significant relationship between results measured by the glucometer and autoanalyzer results from normoglycemic (correlation coefficient [R] = 0.43, P = .02), hypoglycemic (R = 0.95; P < .001), and hyperglycemic (R = 0.81; P < .001) birds. The results of this study suggest that we can predict the real blood-glucose concentration of pigeons by using results obtained by a glucometer.

  16. IFCC reference measurement procedure for substance concentration determination of total carbon dioxide in blood, plasma or serum

    NARCIS (Netherlands)

    Burnett, RW; Covington, AK; Fogh-Andersen, N; Kulpmann, WR; Lewenstam, A; Mas, AHJ; VanKessel, AL; Zijlstra, WG

    A reference measurement procedure for substance concentration determination of total CO, in blood, plasma (the anticoagulant is usually heparin) or serum is described. The document covers the principle of the method, the materials and equipment needed and essential aspects of the procedure. The

  17. Thresholds of whole-blood β-hydroxybutyrate and glucose concentrations measured with an electronic hand-held device to identify ovine hyperketonemia.

    Science.gov (United States)

    Pichler, M; Damberger, A; Schwendenwein, I; Gasteiner, J; Drillich, M; Iwersen, M

    2014-03-01

    Metabolic disorders, especially hyperketonemia, are very common in dairy sheep. The whole-blood concentrations of β-hydroxybutyrate (BHBA) and glucose can be determined by commercially available electronic hand-held devices, which are used in human medicine and for the detection of ketosis in dairy cows. The aim of this study was to evaluate the suitability of the hand-held device Precision Xceed (PX; Abbott Diabetes Care Inc., Abbott Park, IL) to detect hyperketonemia in ewes. An additional objective of this study was to evaluate the agreement between samples obtained by minimal invasive venipuncture of an ear vein and measurements of whole-blood samples from the jugular vein (vena jugularis, v. jug.). Blood samples taken from the v. jug. were collected from 358 ewes on 4 different farms. These samples and a blood drop obtained from an ear vein were analyzed simultaneously on farm with the PX. For method comparison, the samples obtained from the v. jug. were also analyzed by standard methods, which served as the gold standard at the Central Laboratory of the University of Veterinary Medicine Vienna, Austria. The correlation coefficients between the serum BHBA concentration and the concentrations measured with the hand-held meter in the whole blood from an ear vein and the v. jug. were 0.94 and 0.96, respectively. The correlation coefficients of plasma and whole-blood glucose concentration were 0.68 for the v. jug. and 0.47 for the ear vein. The mean glucose concentration was significantly lower in animals classified as hyperketonemic (BHBA ≥ 1.6 mmol/L) compared with healthy ewes. Whole-blood concentrations of BHBA and glucose measured with the PX from v. jug. showed a constant negative bias of 0.15 mmol/L and 8.4 mg/dL, respectively. Hence, a receiver operating characteristic analysis was performed to determine thresholds for the PX to detect hyperketonemia in ewes. This resulted in thresholds for moderate ketosis of BHBA concentrations of 0.7 mmol/L in blood

  18. Determination of natural in vivo noble-gas concentrations in human blood.

    Directory of Open Access Journals (Sweden)

    Yama Tomonaga

    Full Text Available Although the naturally occurring atmospheric noble gases He, Ne, Ar, Kr, and Xe possess great potential as tracers for studying gas exchange in living beings, no direct analytical technique exists for simultaneously determining the absolute concentrations of these noble gases in body fluids in vivo. In this study, using human blood as an example, the absolute concentrations of all stable atmospheric noble gases were measured simultaneously by combining and adapting two analytical methods recently developed for geochemical research purposes. The partition coefficients determined between blood and air, and between blood plasma and red blood cells, agree with values from the literature. While the noble-gas concentrations in the plasma agree rather well with the expected solubility equilibrium concentrations for air-saturated water, the red blood cells are characterized by a distinct supersaturation pattern, in which the gas excess increases in proportion to the atomic mass of the noble-gas species, indicating adsorption on to the red blood cells. This study shows that the absolute concentrations of noble gases in body fluids can be easily measured using geochemical techniques that rely only on standard materials and equipment, and for which the underlying concepts are already well established in the field of noble-gas geochemistry.

  19. Exercise timing and blood lactate concentrations in individuals with type 2 diabetes.

    Science.gov (United States)

    Heden, Timothy D; Liu, Ying; Kanaley, Jill A

    2017-07-01

    The purpose of this study was to characterize how resistance exercise prior to or after a meal alters fasting and postprandial blood lactate concentrations in individuals with type 2 diabetes. Obese individuals with type 2 diabetes (N = 12) completed three 2-day trials, including (i) no exercise (NoEx), (ii) resistance exercise prior to dinner (Ex-M), and (iii) resistance exercise beginning at 45 min postdinner (M-Ex). During day 1 of each trial, fasting and postprandial blood lactate concentrations, perceived exertion, and substrate oxidation were measured, and subsequently on day 2 the following morning fasting blood lactate was measured. The premeal lactate incremental area under the curve (iAUC) during Ex-M (109 ± 66 mmol·L -1 ·1.6 h -1 ) was over 100-fold greater (P 0.05). Perceived exertion, substrate oxidation, or fasting blood lactate concentrations the day after testing were not different between trials. Blood lactate concentrations during acute resistance exercise are greater when exercise is performed in the postprandial period. Acute resistance exercise performed the night prior does not alter fasting blood lactate concentrations the following morning.

  20. Association of sputum and blood eosinophil concentrations with clinical measures of COPD severity: an analysis of the SPIROMICS cohort.

    Science.gov (United States)

    Hastie, Annette T; Martinez, Fernando J; Curtis, Jeffrey L; Doerschuk, Claire M; Hansel, Nadia N; Christenson, Stephanie; Putcha, Nirupama; Ortega, Victor E; Li, Xingnan; Barr, R Graham; Carretta, Elizabeth E; Couper, David J; Cooper, Christopher B; Hoffman, Eric A; Kanner, Richard E; Kleerup, Eric; O'Neal, Wanda K; Paine, Richard; Peters, Stephen P; Alexis, Neil E; Woodruff, Prescott G; Han, MeiLan K; Meyers, Deborah A; Bleecker, Eugene R

    2017-12-01

    Increased concentrations of eosinophils in blood and sputum in chronic obstructive pulmonary disease (COPD) have been associated with increased frequency of exacerbations, reduced lung function, and corticosteroid responsiveness. We aimed to assess whether high eosinophil concentrations in either sputum or blood are associated with a severe COPD phenotype, including greater exacerbation frequency, and whether blood eosinophils are predictive of sputum eosinophils. We did a multicentre observational study analysing comprehensive baseline data from SPIROMICS in patients with COPD aged 40-80 years who had a smoking history of at least 20 pack-years, recruited from six clinical sites and additional subsites in the USA between Nov 12, 2010, and April 21, 2015. Inclusion criteria for this analysis were SPIROMICS baseline visit data with complete blood cell counts and, in a subset, acceptable sputum counts. We stratified patients on the basis of blood and sputum eosinophil concentrations and compared their demographic characteristics, as well as results from questionnaires, clinical assessments, and quantitative CT (QCT). We also analysed whether blood eosinophil concentrations reliably predicted sputum eosinophil concentrations. This study is registered with ClinicalTrials.gov (NCT01969344). Of the 2737 patients recruited to SPIROMICS, 2499 patients were smokers and had available blood counts, and so were stratified by mean blood eosinophil count: 1262 patients with low (George Respiratory Questionnaire symptom scores (p=0·037), and increased wheezing (p=0·018), but no evidence of an association with COPD exacerbations (p=0·35) or the other indices of COPD severity, such as emphysema measured by CT density, COPD assessment test scores, Body-mass index, airflow Obstruction, Dyspnea, and Exercise index, or Global Initiative for Chronic Obstructive Lung Disease stage. Blood eosinophil counts showed a weak but significant association with sputum eosinophil counts

  1. Variation of pH-measurement in platelet concentrates

    NARCIS (Netherlands)

    van der Meer, P. F.; van Zanten, A. P.; Pietersz, R. N.; Reesink, H. W.

    2001-01-01

    To measure pH in platelet concentrates, blood gas analysers with different calibration principles may be used. In this study, variances observed in pH measurements with two types of blood gas analysers were investigated. pH was measured in crystalloid solutions (platelet additive solution (PAS-II),

  2. [Study of blood concentration analysis for formate in acute methanol poisoning].

    Science.gov (United States)

    Morikawa, Go; Okazawa, Katsuko; Shimizu, Takahiro; Otagiri, Sayoko; Fuwa, Fumiko; Nakagawa, Saori; Yamato, Susumu

    2015-09-01

    A 53-year-old woman ingested about 300 mL of 95% methanol. After immediate ethanol antagonist therapy and hemodialysis, she recovered completely. Few days later, the plasma concentration of methanol and formate was measured. A gas chromatography was used for the plasma methanol concentration measurement, and a colorimetric method was used for plasma formate concentration measurement (Formate Colorimetric Assay Kit; BioVision, California, USA). Patient's plasma methanol concentration before hemodialysis was 676.9 mg/dL and plasma formate concentration was 16.9 mg/dL. By removing blood methanol and formate using hemodialysis before formate accumulations in the body, the patient was discharged without any sequelae. We were able to obtain correlation between a gas chromatography and colorimetric method without gas chromatography-mass spectrometry, with good correlation coefficients. The sensitivity was sufficient for analyzing blood sample. Monitoring formate concentration is useful in determining the treatment and evaluating the prognosis of methanol poisoning. We suggest that this colorimetric method is useful in a facility with no access to a gas chromatography in order to measure a plasma formate concentration.

  3. Evaluation of an Electrochemical Point-of-Care Meter for Measuring Glucose Concentration in Blood from Periparturient Dairy Cattle.

    Science.gov (United States)

    Megahed, A A; Hiew, M W H; Townsend, J R; Messick, J B; Constable, P D

    2015-01-01

    The Precision Xtra(®) meter is a promising low cost electrochemical point-of-care unit for measuring blood glucose concentration ([gluc]) in cattle blood. The meter uses an algorithm that assumes the intra-erythrocyte [gluc] equals the plasma [gluc] on a molal basis, and that the hematocrit is similar in humans and cattle. The primary objective was to determine the accuracy of the meter for measuring plasma [gluc] in dairy cattle. Secondary objectives were to characterize the influence of hematocrit and sample temperature on the measured value for [gluc]. A total of 106 periparturient Holstein-Friesian cattle. Blood and plasma samples (1,109) were obtained and Deming regression and Bland-Altman plots were used to determine the accuracy of the meter against the reference method (plasma hexokinase assay). Multivariable regression and linear regression were used to determine the effect of hematocrit and sample temperature on the plasma [gluc] measured by the meter. Intra-erythrocyte [gluc] was 18% of plasma [gluc] on a molar basis. Sample temperature had a significant linear effect on plasma [gluc] as measured by the meter for 3/5 plasma samples when measured [gluc] > 160 mg/dL. The meter utilizes an algorithm that is optimized for human blood and is inaccurate when applied to bovine blood. Until a cattle-specific algorithm is developed, we recommend using plasma as the analyte instead of blood and calculating plasma [gluc] using the equation: [gluc] = 0.66 × [gluc]p-meter + 15, where [gluc]p-meter is the value reported by the meter. If blood is measured, then we recommend using the equation: [gluc] = 0.90 × [gluc]b-meter + 15. Copyright © 2015 The Authors. Journal of Veterinary Internal Medicine published by Wiley Periodicals, Inc. on behalf of the American College of Veterinary Internal Medicine.

  4. Prediction Methods for Blood Glucose Concentration

    DEFF Research Database (Denmark)

    “Recent Results on Glucose–Insulin Predictions by Means of a State Observer for Time-Delay Systems” by Pasquale Palumbo et al. introduces a prediction model which in real time predicts the insulin concentration in blood which in turn is used in a control system. The method is tested in simulation...... EEG signals to predict upcoming hypoglycemic situations in real-time by employing artificial neural networks. The results of a 30-day long clinical study with the implanted device and the developed algorithm are presented. The chapter “Meta-Learning Based Blood Glucose Predictor for Diabetic......, but the insulin amount is chosen using factors that account for this expectation. The increasing availability of more accurate continuous blood glucose measurement (CGM) systems is attracting much interest to the possibilities of explicit prediction of future BG values. Against this background, in 2014 a two...

  5. Accurate measurement of peripheral blood mononuclear cell concentration using image cytometry to eliminate RBC-induced counting error.

    Science.gov (United States)

    Chan, Leo Li-Ying; Laverty, Daniel J; Smith, Tim; Nejad, Parham; Hei, Hillary; Gandhi, Roopali; Kuksin, Dmitry; Qiu, Jean

    2013-02-28

    Peripheral blood mononuclear cells (PBMCs) have been widely researched in the fields of immunology, infectious disease, oncology, transplantation, hematological malignancy, and vaccine development. Specifically, in immunology research, PBMCs have been utilized to monitor concentration, viability, proliferation, and cytokine production from immune cells, which are critical for both clinical trials and biomedical research. The viability and concentration of isolated PBMCs are traditionally measured by manual counting with trypan blue (TB) using a hemacytometer. One of the common issues of PBMC isolation is red blood cell (RBC) contamination. The RBC contamination can be dependent on the donor sample and/or technical skill level of the operator. RBC contamination in a PBMC sample can introduce error to the measured concentration, which can pass down to future experimental assays performed on these cells. To resolve this issue, RBC lysing protocol can be used to eliminate potential error caused by RBC contamination. In the recent years, a rapid fluorescence-based image cytometry system has been utilized for bright-field and fluorescence imaging analysis of cellular characteristics (Nexcelom Bioscience LLC, Lawrence, MA). The Cellometer image cytometry system has demonstrated the capability of automated concentration and viability detection in disposable counting chambers of unpurified mouse splenocytes and PBMCs stained with acridine orange (AO) and propidium iodide (PI) under fluorescence detection. In this work, we demonstrate the ability of Cellometer image cytometry system to accurately measure PBMC concentration, despite RBC contamination, by comparison of five different total PBMC counting methods: (1) manual counting of trypan blue-stained PBMCs in hemacytometer, (2) manual counting of PBMCs in bright-field images, (3) manual counting of acetic acid lysing of RBCs with TB-stained PBMCs, (4) automated counting of acetic acid lysing of RBCs with PI-stained PBMCs

  6. Ammonia concentrations in arterial blood, venous blood, and cerebrospinal fluid of dogs with and without congenital extrahepatic portosystemic shunts.

    Science.gov (United States)

    Or, Matan; Devriendt, Nausikaa; Kitshoff, Adriaan M; Peremans, Kathelijne; Vandermeulen, Eva; Paepe, Dominique; Polis, Ingeborgh; Martlé, Valentine; de Rooster, Hilde

    2017-11-01

    OBJECTIVE To compare ammonia concentrations in arterial blood, venous blood, and CSF samples of dogs with and without extrahepatic portosystemic shunts (EHPSS). ANIMALS 19 dogs with congenital EHPSS and 6 healthy control dogs. PROCEDURES All dogs underwent a physical examination and then were anesthetized for transsplenic portal scintigraphy to confirm the presence or absence of EHPSS. While dogs were anesthetized, arterial and venous blood samples and a CSF sample were simultaneously collected for determination of ammonia concentration, which was measured by use of a portable blood ammonia analyzer (device A) and a nonportable biochemical analyzer (device B). Results were compared between dogs with EHPSS and control dogs. RESULTS Arterial, venous, and CSF ammonia concentrations for dogs with EHPSS were significantly greater than those for control dogs. For dogs with EHPSS, ammonia concentrations in both arterial and venous blood samples were markedly increased from the reference range. There was a strong positive correlation between arterial and venous ammonia concentrations and between blood (arterial or venous) and CSF ammonia concentrations. CONCLUSIONS AND CLINICAL RELEVANCE Results indicated that blood and CSF ammonia concentrations in dogs with EHPSS were greater than those for healthy dogs and were strongly and positively correlated, albeit in a nonlinear manner. This suggested that the permeability of the blood-brain barrier to ammonia may be abnormally increased in dogs with EHPSS, but further investigation of the relationship between blood or CSF ammonia concentration and clinical signs of hepatic encephalopathy or the surgical outcome for dogs with EHPSS is warranted.

  7. Characterization of the analytic performance of an electrochemical point-of-care meter for measuring β-hydroxybutyrate concentration in blood and plasma from periparturient dairy cattle.

    Science.gov (United States)

    Megahed, Ameer A; Hiew, Mark W H; Townsend, Jonathan R; Constable, Peter D

    2017-06-01

    The Precision Xtra electrochemical meter is widely used to measure blood β-hydroxybutyrate concentration (BHBb) in dairy cattle. The meter uses an algorithm optimized for human blood that assumes the HCT in cattle is the same as in people, and that intra-erythrocyte β-hydroxybutyrate (BHBe) and plasma β-hydroxybutyrate (BHBp) concentration are equivalent. The first objective was to characterize the analytic performance of the meter for measuring BHBb and BHBp in dairy cattle. The second objective was to characterize the influence of HCT and sample temperature on BHBp concentration measured by the meter. Blood and plasma samples were obtained from 106 periparturient Holstein cattle and 15 lactating Holstein cows with experimentally induced electrolyte and acid-base imbalances. Meter performance was evaluated using Deming regression and Bland-Altman plots. Multivariable linear regression was used to determine the effect of HCT and sample temperature on BHBb and BHBp concentration, respectively. The meter was linear up to BHB = 3.0 mmol/L as measured by the reference method, equivalent to meter values for BHBb > 4.5 mmol/L and BHBp > 5.2 mmol/L. An increase in HCT resulted in higher BHBb concentration. This result was partially explained by BHBe being much lower than BHBp. Changes in sample temperature caused a linear change in measured BHBp whenever BHBp > 3.0 mmol/L. Meter accuracy was markedly dependent on the BHBe-to-BHBp ratio and consequently the HCT. Therefore, the algorithm used by the meter should be revised when applied to bovine blood for improved accuracy. © 2017 American Society for Veterinary Clinical Pathology.

  8. Uranium concentration measurements in human blood for some governorates in Iraq using CR-39 track detector

    International Nuclear Information System (INIS)

    Tawfiq, N.F.; Ali, L.T.; Al-Jobouri, H.A.

    2013-01-01

    The sensitive and simple technique of fission track etch has been applied to determine trace concentration of uranium in blood samples for occupational and non-occupational workers, male and female, using CR-39 track detector that is employed for registration of induced fission tracks. The results show that the highest recorded uranium concentration in human blood of workers in the ministry of Science and Technology were 1.90 ppb (male, 36 years old, 12 years' work experience, and living in Basrah governorate) and minimum concentration 0.26 ppb (female, 40 years old, 10 years' work experience, and living in Baghdad), while for non-occupational worker, the maximum uranium concentration was 1.76 ppb (female, 63 years old, and living in Al-Muthana) and minimum concentration was 0.28 ppb (female, 20 years old, and living in Baghdad). It has also been found that the uranium concentration in human blood samples of workers in the ministry of Science and Technology are higher than those of non-occupational workers, and the uranium concentrations for female workers and for non-occupational workers were higher than those for male workers and non-occupational workers. (author)

  9. Optoacoustic monitoring of blood hemoglobin concentration: a pilot clinical study

    Science.gov (United States)

    Petrova, Irina Y.; Esenaliev, Rinat O.; Petrov, Yuriy Y.; Brecht, Hans-Peter F.; Svensen, Christer H.; Olsson, Joel; Deyo, Donald J.; Prough, Donald S.

    2005-07-01

    The optoacoustic technique is noninvasive, has high spatial resolution, and potentially can be used to measure the total hemoglobin concentration ([THb]) continuously and accurately. We performed in vitro measurements in blood and in vivo tests in healthy volunteers. Our clinical protocol included rapid infusion of intravenous saline to simulate rapid change in the [THb] during fluid therapy or surgery. Optoacoustic measurements were made from the wrist area overlying the radial artery for more than 1 h. The amplitude of the optoacoustic signal generated in the radial artery closely followed the [THb] measured directly in concurrently collected blood samples.

  10. Predictors of blood trihalomethane concentrations in NHANES 1999-2006.

    Science.gov (United States)

    Riederer, Anne M; Dhingra, Radhika; Blount, Benjamin C; Steenland, Kyle

    2014-07-01

    Trihalomethanes (THMs) are water disinfection by-products that have been associated with bladder cancer and adverse birth outcomes. Four THMs (bromoform, chloroform, bromodichloromethane, dibromochloromethane) were measured in blood and tap water of U.S. adults in the National Health and Nutrition Examination Survey (NHANES) 1999-2006. THMs are metabolized to potentially toxic/mutagenic intermediates by cytochrome p450 (CYP) 2D6 and CYP2E1 enzymes. We conducted exploratory analyses of blood THMs, including factors affecting CYP2D6 and CYP2E1 activity. We used weighted multivariable regressions to evaluate associations between blood THMs and water concentrations, survey year, and other factors potentially affecting THM exposure or metabolism (e.g., prescription medications, cruciferous vegetables, diabetes, fasting, pregnancy, swimming). From 1999 to 2006, geometric mean blood and water THM levels dropped in parallel, with decreases of 32%-76% in blood and 38%-52% in water, likely resulting, in part, from the lowering of the total THM drinking water standard in 2002-2004. The strongest predictors of blood THM levels were survey year and water concentration (n = 4,232 total THM; n = 4,080 bromoform; n = 4,582 chloroform; n = 4,374 bromodichloromethane; n = 4,464 dibromochloromethane). We detected statistically significant inverse associations with diabetes and eating cruciferous vegetables in all but the bromoform model. Medications did not consistently predict blood levels. Afternoon/evening blood samples had lower THM concentrations than morning samples. In a subsample (n = 230), air chloroform better predicted blood chloroform than water chloroform, suggesting showering/bathing was a more important source than drinking. We identified several factors associated with blood THMs that may affect their metabolism. The potential health implications require further study.

  11. Usefulness of estimation of blood procalcitonin concentration versus C-reactive protein concentration and white blood cell count for therapeutic monitoring of sepsis in neonates

    Directory of Open Access Journals (Sweden)

    Agnieszka Kordek

    2014-12-01

    Full Text Available Aim: This study was intended to assess the clinical usefulness of blood procalcitonin (PCT concentrations for the diagnosis and therapeutic monitoring of nosocomial neonatal sepsis.Material/Methods: The enrolment criterion was sepsis clinically manifesting after three days of life. PCT concentrations were measured in venous blood from 52 infected and 88 uninfected neonates. The results were interpreted against C-reactive protein (CRP concentrations and white blood cell counts (WBC.Results: Differences between the two groups in PCT and CRP concentrations were highly significant. No significant differences between the groups were noted for WBC. The threshold value on the receiver operator characteristic curve was 2.06 ng/mL for PCT (SE 75%; SP 80.68%; PPV 62.22%; NPV 88.75%; AUC 0.805, 5.0 mg/L for CRP (SE 67.44%; SP 73.68%; PPV 42.02%; NPV 88.89%; AUC 0.801, and 11.9 x109/L for WBC (SE 51.16%; SP 50.68%; PPV 23.16%; NPV 78.13%; AUC 0.484. Procalcitonin concentrations decreased 24 hours after initiation of antibiotic therapy and reverted to the control level after 5-7 days. C-reactive protein concentrations began to decline after two days of antibiotic therapy but were still higher than in the control group after 5-7 days of treatment. No significant changes in WBC during the treatment were observed.Conclusions: Procalcitonin concentrations in blood appear to be of use for the diagnosis and therapeutic monitoring of nosocomial infections in neonates as this parameter demonstrates greater sensitivity and specificity than C-reactive protein. White blood cell counts appear to be of little diagnostic value in the early phase of infection or for therapeutic monitoring.

  12. Estimation of individual response in finger blood concentration change under occlusion on human arm using speckle patterns

    Science.gov (United States)

    Yokoi, Naomichi; Shinohara, Tomomi; Okazaki, Syunya; Funamizu, Hideki; Kyoso, Masaki; Shimatani, Yuichi; Yuasa, Tomonori; Aizu, Yoshihisa

    2017-07-01

    We have developed the method for imaging blood flow and blood concentration change by using laser speckle in fiber illumination. We experimentally discuss the relationship of blood occlusion condition and individual response of blood concentration change measured by the method.

  13. The relationship between exsanguination blood lactate concentration and carcass quality in slaughter pigs.

    Science.gov (United States)

    Edwards, L N; Engle, T E; Correa, J A; Paradis, M A; Grandin, T; Anderson, D B

    2010-07-01

    A group of 128 cross-bred barrows were used to determine the relationship between exsanguination blood lactate concentration ([LAC]) and carcass quality following commercial marketing conditions. After 10h of feed withdrawal, pigs were loaded on a truck with a hydraulically lifted second deck and transported approximately 1h to the slaughter facility. Pigs were rested for 8h and stunned with carbon dioxide. Blood lactate concentration was measured on exsanguination blood. Fourteen pork quality measurements were obtained following normal post-mortem processing. Pearson correlations were used to determine the relationships between [LAC] and the meat quality parameters. Exsanguination blood lactate concentration ranged from 4 to 19.7 mM. Higher lactate was associated with lower 60 min pH (P=0.0004) and higher drip loss (P=0.02). These results suggest that under low-stress loading and standard marketing conditions, exsanguination [LAC] is predictive of the rate of early post-mortem metabolism. Copyright 2010 Elsevier Ltd. All rights reserved.

  14. Serial changes in plasma K concentration during storage of irradiation blood products

    International Nuclear Information System (INIS)

    Togashi, Kazue; Yamada, Keiko; Otake, Sachiko; Saito, Yukiko; Sugimura, Kazuhito; Takahashi, Hoyu

    1996-01-01

    Irradiation of blood products is highly effective in the prevention of transfusion-associated graft-versus-host disease (GVHD). In order to assess the safe storage period of irradiated blood products, serial changes in plasma K, red cell 2,3-diphosphoglycerate (2,3-DPG) and lactic acid concentrations of whole blood and M·A·P-added red cell concentrate (RC-M·A·P) during storage at 5degC were measured after irradiation with 137 Cs by IBL 437C (CIS bio international). Plasma K concentration did not change immediately after irradiation, but increased more rapidly and in a radiation dose-dependent manner in the irradiated products than nonirradiated products. The changes in red cell 2,3-DPG and lactic acid concentrations were not affected by irradiation but were rather dependent on the storage period after blood collection. Plasma K concentrations of whole blood and RC-M·A·P irradiated with 25 Gy increased at 5 and 3 days, respectively, to the K levels observed after the storage of nonirradiated products for 21 days. It is therefore recommended that whole blood be used within 5 days and RC-M·A·P within 3 days when stored after irradiation with 25 Gy. (author)

  15. Predictors of Blood Trihalomethane Concentrations in NHANES 1999–2006

    Science.gov (United States)

    Dhingra, Radhika; Blount, Benjamin C.; Steenland, Kyle

    2014-01-01

    Background: Trihalomethanes (THMs) are water disinfection by-products that have been associated with bladder cancer and adverse birth outcomes. Four THMs (bromoform, chloroform, bromodichloromethane, dibromochloromethane) were measured in blood and tap water of U.S. adults in the National Health and Nutrition Examination Survey (NHANES) 1999–2006. THMs are metabolized to potentially toxic/mutagenic intermediates by cytochrome p450 (CYP) 2D6 and CYP2E1 enzymes. Objectives: We conducted exploratory analyses of blood THMs, including factors affecting CYP2D6 and CYP2E1 activity. Methods: We used weighted multivariable regressions to evaluate associations between blood THMs and water concentrations, survey year, and other factors potentially affecting THM exposure or metabolism (e.g., prescription medications, cruciferous vegetables, diabetes, fasting, pregnancy, swimming). Results: From 1999 to 2006, geometric mean blood and water THM levels dropped in parallel, with decreases of 32%–76% in blood and 38%–52% in water, likely resulting, in part, from the lowering of the total THM drinking water standard in 2002–2004. The strongest predictors of blood THM levels were survey year and water concentration (n = 4,232 total THM; n = 4,080 bromoform; n = 4,582 chloroform; n = 4,374 bromodichloromethane; n = 4,464 dibromochloromethane). We detected statistically significant inverse associations with diabetes and eating cruciferous vegetables in all but the bromoform model. Medications did not consistently predict blood levels. Afternoon/evening blood samples had lower THM concentrations than morning samples. In a subsample (n = 230), air chloroform better predicted blood chloroform than water chloroform, suggesting showering/bathing was a more important source than drinking. Conclusions: We identified several factors associated with blood THMs that may affect their metabolism. The potential health implications require further study. Citation: Riederer AM, Dhingra R

  16. Cutpoints for screening blood glucose concentrations in healthy senior cats.

    Science.gov (United States)

    Reeve-Johnson, Mia K; Rand, Jacquie S; Vankan, Dianne; Anderson, Stephen T; Marshall, Rhett; Morton, John M

    2017-12-01

    Objectives The objectives of this study were to determine the reference interval for screening blood glucose in senior cats, to apply this to a population of obese senior cats, to compare screening and fasting blood glucose, to assess whether screening blood glucose is predicted by breed, body weight, body condition score (BCS), behaviour score, fasting blood glucose and/or recent carbohydrate intake and to assess its robustness to changes in methodology. Methods The study included a total of 120 clinically healthy client-owned cats aged 8 years and older of varying breeds and BCSs. Blood glucose was measured at the beginning of the consultation from an ear/paw sample using a portable glucose meter calibrated for cats, and again after physical examination from a jugular sample. Fasting blood glucose was measured after overnight hospitalisation and fasting for 18-24 h. Results The reference interval upper limit for screening blood glucose was 189 mg/dl (10.5 mmol/l). Mean screening blood glucose was greater than mean fasting glucose. Breed, body weight, BCS, behaviour score, fasting blood glucose concentration and amount of carbohydrate consumed 2-24 h before sampling collectively explained only a small proportion of the variability in screening blood glucose. Conclusions and relevance Screening blood glucose measurement represents a simple test, and cats with values from 117-189 mg/dl (6.5-10.5 mmol/l) should be retested several hours later. Cats with initial screening blood glucose >189 mg/dl (10.5 mmol/l), or a second screening blood glucose >116 mg/dl (6.4 mmol/l) several hours after the first, should have fasting glucose and glucose tolerance measured after overnight hospitalisation.

  17. Manganese concentration in the spinal cords and blood corpuscles of amyotrophic lateral sclerosis patients

    Energy Technology Data Exchange (ETDEWEB)

    Miyata, Satoru; Toyoshima, Masanori; Otsuki, Yuzo; Nagata, Hiroshi; Nakamura, Shigenobu (Kyoto Univ. (Japan). Faculty of Medicine)

    1981-11-01

    Manganese concentration in the spinal cord tissues and the blood corpuscles from patients with amyotrophic lateral sclerosis (ALS) and other diseases were measured by neutron activation analysis. The mean manganese concentration in the spinal cord from ALS patients was significantly higher than that from control subjects, especially in the anterior horn of the cervical cord. In order to determine the manganese concentration in blood corpuscles by neutron activation analysis, it was necessary to subtract /sup 56/Mn derived from the /sup 56/Fe(n, p)/sup 56/Mn reaction. The mean Mn concentration in the blood corpuscles from ALS patients seems to be lower than that from patients with other diseases. Fe, Se, Rb and Zn concentrations in the blood corpuscles from ALS patients were not different from those of patients with other diseases.

  18. Manganese concentration in the spinal cords and blood corpuscles of amyotrophic lateral sclerosis patients

    International Nuclear Information System (INIS)

    Miyata, Satoru; Toyoshima, Masanori; Otsuki, Yuzo; Nagata, Hiroshi; Nakamura, Shigenobu

    1981-01-01

    Manganese concentration in the spinal cord tissues and the blood corpuscles from patients with amyotrophic lateral sclerosis (ALS) and other diseases were measured by neutron activation analysis. The mean manganese concentration in the spinal cord from ALS patients was significantly higher than that from control subjects, especially in the anterior horn of the cervical cord. In order to determine the manganese concentration in blood corpuscles by neutron activation analysis, it was necessary to subtract 56 Mn derived from the 56 Fe(n, p) 56 Mn reaction. The mean Mn concentration in the blood corpuscles from ALS patients seems to be lower than that from patients with other diseases. Fe, Se, Rb and Zn concentrations in the blood corpuscles from ALS patients were not different from those of patients with other diseases. (author)

  19. Perfluoroalkyl Acid Concentrations in Blood Samples Subjected to Transportation and Processing Delay.

    Science.gov (United States)

    Bach, Cathrine Carlsen; Henriksen, Tine Brink; Bossi, Rossana; Bech, Bodil Hammer; Fuglsang, Jens; Olsen, Jørn; Nohr, Ellen Aagaard

    2015-01-01

    In studies of perfluoroalkyl acids, the validity and comparability of measured concentrations may be affected by differences in the handling of biospecimens. We aimed to investigate whether measured plasma levels of perfluoroalkyl acids differed between blood samples subjected to delay and transportation prior to processing and samples with immediate processing and freezing. Pregnant women recruited at Aarhus University Hospital, Denmark, (n = 88) provided paired blood samples. For each pair of samples, one was immediately processed and plasma was frozen, and the other was delayed and transported as whole blood before processing and freezing of plasma (similar to the Danish National Birth Cohort). We measured 12 perfluoroalkyl acids and present results for compounds with more than 50% of samples above the lower limit of quantification. For samples taken in the winter, relative differences between the paired samples ranged between -77 and +38% for individual perfluoroalkyl acids. In most cases concentrations were lower in the delayed and transported samples, e.g. the relative difference was -29% (95% confidence interval -30; -27) for perfluorooctane sulfonate. For perfluorooctanoate there was no difference between the two setups [corresponding estimate 1% (0, 3)]. Differences were negligible in the summer for all compounds. Transport of blood samples and processing delay, similar to conditions applied in some large, population-based studies, may affect measured perfluoroalkyl acid concentrations, mainly when outdoor temperatures are low. Attention to processing conditions is needed in studies of perfluoroalkyl acid exposure in humans.

  20. Measurement of organ blood flow using tritiated water. II. Uterine blood flow in conscious pregnant ewes

    International Nuclear Information System (INIS)

    Brown, B.W.; Oddy, V.H.; Jones, A.W.

    1982-01-01

    Total uterine blood flow was measured with a tritiated water (TOH) diffusion method and with radioactive microspheres in six, conscious, pregnant ewes. With continuous infusion of TOH, equilibrium between the TOH concentration in utero-ovarian venous blood and arterial blood was attained within 50 min of the start of the infusion. The concentration of TOH in uterine and foetal tissue and in foetal blood water was the same as that in uterine venous water by 40 min; at this time, the concentration of TOH in the water of amniotic and allantoic fluids was 96% of that in uterine venous blood water. Estimates of total uterine blood flow obtained using TOH were highly correlated with those obtained with microspheres and the corresponding mean flow values obtained with the two techniques did not significantly differ. The percentage of the total uterine blood flow passing through arteriovenous anastomoses ranged from 1.4 to 3.3%

  1. Evaluation of CF/CM, concentration ratios for elements in fetus to mother, using cord blood and maternal blood

    International Nuclear Information System (INIS)

    Watanabe, Y.; Yukawa, M.; Kim, H.S.; Nishimura, Y.; Osada, H.; Sekiya, S.

    2000-01-01

    ICRP recommends age-dependent dose evaluation for intakes of radionuclides by inhalation and ingestion, and gave age-specific biokinetic models and dose coefficients (doses per unit intake) for infants, children and adults in the publications. Dose coefficients are also needed for the assessment of exposures received in utero and after birth by the offspring of the woman who has received intakes of radionuclides. In the model that has been adopted by ICRP, the doses to the developing fetus are calculated using CF/CM values, concentration ratios for radionuclides in the fetus and the maternal tissues. The purpose of this study is to evaluate the CF/CM of each radionuclide by the measurement of element concentration in cord blood and maternal blood. Blood samples were obtained from 35 mothers who delivered in Department of Obstetrics and Gynecology of Chiba University. Just after the delivery, unbiblical cord blood was sampled. Maternal blood was also obtained from the arm vein within 30 minutes after the delivery. The serum was separated from the blood sample with centrifugation. About 50 mg of freezer-dried whole blood and serum were digested with 0.5 ml of 65% ultra-pure nitric acid and 0.2 ml of 30% hydrogen peroxide in a microwave digester. The diluted solutions were used for the determination of elements by ICP-MS (Inductively Coupled Plasma Mass Spectrometry) and ICP-AES (Inductively Coupled Plasma Atomic Emission Spectrometry). The elements determined in these samples included Mg, K, Ca, Mn, Fe, Cu, Zn, Se, Rb, Sr and Cs. The concentration of Cu was higher in the maternal blood than in the cord blood in both whole blood and serum. On the other hand, Mn and Fe were higher in the cord blood. The differences of concentration ratios among elements and the differences among tissues will be discussed. (author)

  2. A method for estimation of plasma albumin concentration from the buffering properties of whole blood

    DEFF Research Database (Denmark)

    Rees, Stephen Edward; Diemer, Tue; Kristensen, Søren Risom

    2012-01-01

    measurements of acid-base and oxygenation status. This article presents and evaluates a new method for doing so. MATERIALS AND METHODS: The mathematical method for estimating plasma albumin concentration is described. To evaluate the method at numerous albumin concentrations, blood from 19 healthy subjects......PURPOSE: Hypoalbuminemia is strongly associated with poor clinical outcome. Albumin is usually measured at the central laboratory rather than point of care, but in principle, information exists in the buffering properties of whole blood to estimate plasma albumin concentration from point of care...

  3. Single-cell measurement of red blood cell oxygen affinity

    OpenAIRE

    Caprio, Di; Stokes, Chris; Higgins, John M.; Schonbrun, Ethan

    2015-01-01

    Oxygen is transported throughout the body by hemoglobin in red blood cells. While the oxygen affinity of blood is well understood and is routinely assessed in patients by pulse oximetry, variability at the single-cell level has not been previously measured. In contrast, single-cell measurements of red blood cell volume and hemoglobin concentration are taken millions of times per day by clinical hematology analyzers and are important factors in determining the health of the hematologic system....

  4. Circadian melatonin concentration rhythm is lost in pregnant women with altered blood pressure rhythm.

    Science.gov (United States)

    Tranquilli, A L; Turi, A; Giannubilo, S R; Garbati, E

    2004-03-01

    We assessed the correlation between the rhythm of melatonin concentration and circadian blood pressure patterns in normal and hypertensive pregnancy. Ambulatory 24-h blood pressure and blood samples every 4 h were monitored in 16 primigravidae who had shown an abnormal circadian blood pressure pattern (eight pre-eclamptic and eight normotensive) in pregnancy and 6-12 months after pregnancy. The circadian rhythm was analyzed by chronobiological measures. Eight normotensive women with maintained blood pressure rhythm served as controls. During pregnancy, melatonin concentration was significantly higher in pre-eclamptic than in normotensive women (pre-eclampsia, 29.4 +/- 1.9 pg/ml, normotensin, altered rhythm, 15.6 +/- 2.1; controls, 22.7 +/- 1.8; p lost in all pregnant women with loss of blood pressure rhythm. After pregnancy, normotensive women showed a reappearance of both melatonin and blood pressure rhythm, whereas pre-eclamptic women showed a reappearance of blood pressure but not melatonin rhythm. The loss of blood pressure rhythm in pregnancy is consistent with the loss of melatonin concentration rhythm. In pre-eclamptic women, the normalization of blood pressure rhythm, while melatonin rhythm remained altered, suggests a temporal or causal priority of circadian concentration of melatonin in the determination of blood pressure trend.

  5. Fasting blood glucose and haemoglobin concentrations of healthy ...

    African Journals Online (AJOL)

    Menstruation is associated with loss of blood monthly in women of reproductive age. In some women this physiological phenomenon is also associated with some complaints such as menstrual pain, vomiting, and tiredness. We investigated the fasting blood glucose concentration and hemoglobin concentration before and ...

  6. Measurement of regional cerebral blood flow using one-point venous blood sampling and causality model. Evaluation by comparing with conventional continuous arterial blood sampling method

    International Nuclear Information System (INIS)

    Mimura, Hiroaki; Sone, Teruki; Takahashi, Yoshitake

    2008-01-01

    Optimal setting of the input function is essential for the measurement of regional cerebral blood flow (rCBF) based on the microsphere model using N-isopropyl-4-[ 123 I]iodoamphetamine ( 123 I-IMP), and usually the arterial 123 I-IMP concentration (integral value) in the initial 5 min is used for this purpose. We have developed a new convenient method in which 123 I-IMP concentration in arterial blood sample is estimated from that in venous blood sample. Brain perfusion single photon emission computed tomography (SPECT) with 123 I-IMP was performed in 110 cases of central nervous system disorders. The causality was analyzed between the various parameters of SPECT data and the ratio of octanol-extracted arterial radioactivity concentration during the first 5 min (Caoct) to octanol-extracted venous radioactivity concentration at 27 min after intravenous injection of 123 I-IMP (Cvoct). A high correlation was observed between the measured and estimated values of Caoct/Cvoct (r=0.856) when the following five parameters were included in the regression formula: radioactivity concentration in venous blood sampled at 27 min (Cv), Cvoct, Cvoct/Cv, and total brain radioactivity counts that were measured by a four-head gamma camera 5 min and 28 min after 123 I-IMP injection. Furthermore, the rCBF values obtained using the input parameters estimated by this method were also highly correlated with the rCBF values measured using the continuous arterial blood sampling method (r=0.912). These results suggest that this method would serve as the new, convenient and less invasive method of rCBF measurement in clinical setting. (author)

  7. No relationship between cerebral blood flow velocity and cerebrovascular reserve capacity and contemporaneously measured glucose and insulin concentrations in diabetes mellitus

    NARCIS (Netherlands)

    Fülesdi, B.; Limburg, M.; Bereczki, D.; Molnár, C.; Michels, R. P.; Leányvári, Z.; Csiba, L.

    1999-01-01

    Blood glucose and insulin concentrations have been reported to influence cerebral hemodynamics. We studied the relationship between actual blood glucose and insulin concentrations and resting cerebral blood flow velocity in the middle cerebral artery and cerebrovascular reserve capacity after

  8. Laser system for measuring small changes in plasma tracer concentrations.

    Science.gov (United States)

    Klaesner, J W; Pou, N A; Parker, R E; Galloway, R L; Roselli, R J

    1996-01-01

    The authors developed a laser-diode system that can be used for on-line optical concentration measurements in physiologic systems. Previous optical systems applied to whole blood have been hampered by artifacts introduced by red blood cells (RBCs). The system introduced here uses a commercially available filter cartridge to separate RBCs from plasma before plasma concentration measurements are made at a single wavelength. The filtering characteristics of the Cellco filter cartridge (#4007-10, German-town, MD) were adequate for use in the on-line measurement system. The response time of the filter cartridge was less than 40 seconds, and the sieving characteristics of the filter for macromolecules were excellent, with filtrate-to-plasma albumin ratios of 0.98 +/- 0.11 for studies in sheep and 0.94 +/- 0.15 for studies in dogs. The 635-nm laser diode system developed was shown to be more sensitive than the spectrophotometer used in previous studies (Klaesner et al., Annals of Biomedical Engineering, 1994; 22, 660-73). The new system was used to measure the product of filtration coefficient (Kfc) and reflection coefficient for albumin (delta f) in an isolated canine lung preparation. The delta fKfc values [mL/(cmH2O.min.100 g dry lung weight)] measured with the laser diode system (0.33 +/- 0.22) compared favorably with the delta fKfc obtained using a spectrophotometer (0.27 +/- 0.20) and with the Kfc obtained using the blood-corrected gravimetric method (0.32 +/- 0.23). Thus, this new optical system was shown to accurately measure plasma concentration changes in whole blood for physiologic levels of Kfc. The same system can be used with different optical tracers and different source wavelengths to make optical plasma concentration measurements for other physiologic applications.

  9. A method for estimating radioactive cesium concentrations in cattle blood using urine samples.

    Science.gov (United States)

    Sato, Itaru; Yamagishi, Ryoma; Sasaki, Jun; Satoh, Hiroshi; Miura, Kiyoshi; Kikuchi, Kaoru; Otani, Kumiko; Okada, Keiji

    2017-12-01

    In the region contaminated by the Fukushima nuclear accident, radioactive contamination of live cattle should be checked before slaughter. In this study, we establish a precise method for estimating radioactive cesium concentrations in cattle blood using urine samples. Blood and urine samples were collected from a total of 71 cattle on two farms in the 'difficult-to-return zone'. Urine 137 Cs, specific gravity, electrical conductivity, pH, sodium, potassium, calcium, and creatinine were measured and various estimation methods for blood 137 Cs were tested. The average error rate of the estimation was 54.2% without correction. Correcting for urine creatinine, specific gravity, electrical conductivity, or potassium improved the precision of the estimation. Correcting for specific gravity using the following formula gave the most precise estimate (average error rate = 16.9%): [blood 137 Cs] = [urinary 137 Cs]/([specific gravity] - 1)/329. Urine samples are faster to measure than blood samples because urine can be obtained in larger quantities and has a higher 137 Cs concentration than blood. These advantages of urine and the estimation precision demonstrated in our study, indicate that estimation of blood 137 Cs using urine samples is a practical means of monitoring radioactive contamination in live cattle. © 2017 Japanese Society of Animal Science.

  10. Measurement of plasma adenosine concentration: methodological and physiological considerations

    International Nuclear Information System (INIS)

    Gewirtz, H.; Brown, P.; Most, A.S.

    1987-01-01

    This study tested the hypothesis that measurements of plasma adenosine concentration made on samples of blood obtained in dipyridamole and EHNA (i.e., stopping solution) may be falsely elevated as a result of ongoing in vitro production and accumulation of adenosine during sample processing. Studies were performed with samples of anticoagulated blood obtained from anesthesized domestic swine. Adenosine concentration of ultra filtrated plasma was determined by HPLC. The following parameters were evaluated: (i) rate of clearance of [ 3 H]adenosine added to plasma, (ii) endogenous adenosine concentration of matched blood samples obtained in stopping solution alone, stopping solution plus EDTA, and perchloric acid (PCA), (iii) plasma and erythrocyte endogenous adenosine concentration in nonhemolyzed samples, and (iv) plasma adenosine concentration of samples hemolyzed in the presence of stopping solution alone or stopping solution plus EDTA. We observed that (i) greater than or equal to 95% of [ 3 H]adenosine added to plasma is removed from it by formed elements of the blood in less than 20 s, (ii) plasma adenosine concentration of samples obtained in stopping solution alone is generally 10-fold greater than that of matched samples obtained in stopping solution plus EDTA, (iii) deliberate mechanical hemolysis of blood samples obtained in stopping solution alone resulted in substantial augmentation of plasma adenosine levels in comparison with matched nonhemolyzed specimens--addition of EDTA to stopping solution prevented this, and (iv) adenosine content of blood samples obtained in PCA agreed closely with the sum of plasma and erythrocyte adenosine content of samples obtained in stopping solution plus EDTA

  11. Postmortem Femoral Blood Concentrations of Risperidone

    DEFF Research Database (Denmark)

    Linnet, Kristian; Johansen, Sys Stybe

    2014-01-01

    Postmortem femoral blood concentrations of the antipsychotic drug risperidone and the active metabolite 9-hydroxyrisperidone were determined by an achiral LC-MS/MS method in 38 cases. The cause of death was classified as unrelated to risperidone in 30 cases, in which the sum of the concentration ...

  12. Precision and accuracy of blood glucose measurements using three different instruments.

    Science.gov (United States)

    Nowotny, B; Nowotny, P J; Strassburger, K; Roden, M

    2012-02-01

    Assessment of insulin sensitivity by dynamic metabolic tests such as the hyperinsulinemic euglycemic clamp critically relies on the reproducible and fast measurement of blood glucose concentrations. Although various instruments have been developed over the last decades, little is known as to the accuracy and comparability. We therefore compared the best new instrument with the former gold standard instruments to measure glucose concentrations in metabolic tests. Fasting blood samples of 15 diabetic and 10 healthy subjects were collected into sodium-fluoride tubes, spiked with glucose (0, 2.8, 6.9 and 11.1 mmol/l) and measured either as whole blood (range 3.3-26.3 mmol/l) or following centrifugation as plasma (range 3.9-32.0 mmol/l). Plasma samples were analyzed in the YSI-2300 STAT plus (YSI), EKF Biosen C-Line (EKF) and the reference method, Beckman Glucose analyzer-II (BMG), whole blood samples in EKF instruments with YSI as reference method. The average deviation of the EKF from the reference, BMG, was 3.0 ± 3.5% without any concentration-dependent variability. Glucose measurements by YSI were in good agreement with that by BMG (plasma) and EKF (plasma and whole blood) up to concentrations of 13.13 mmol/l (0.5 ± 3.7%), but deviation increased to -6.2 ± 3.8% at higher concentrations. Precision (n = 6) was ±2.2% (YSI), ±3.9% (EKF) and ±5.2% (BMG). The EKF instrument is comparable regarding accuracy and precision to the reference method BMG and can be used in metabolic tests, while the YSI showed a systematic shift at higher glucose concentrations. Based on these results we decided to replace BMG with EKF instrument in metabolic tests. © 2012 The Authors. Diabetic Medicine © 2012 Diabetes UK.

  13. Novel system using microliter order sample volume for measuring arterial radioactivity concentrations in whole blood and plasma for mouse PET dynamic study.

    Science.gov (United States)

    Kimura, Yuichi; Seki, Chie; Hashizume, Nobuya; Yamada, Takashi; Wakizaka, Hidekatsu; Nishimoto, Takahiro; Hatano, Kentaro; Kitamura, Keishi; Toyama, Hiroshi; Kanno, Iwao

    2013-11-21

    This study aimed to develop a new system, named CD-Well, for mouse PET dynamic study. CD-Well allows the determination of time-activity curves (TACs) for arterial whole blood and plasma using 2-3 µL of blood per sample; the minute sample size is ideal for studies in small animals. The system has the following merits: (1) measures volume and radioactivity of whole blood and plasma separately; (2) allows measurements at 10 s intervals to capture initial rapid changes in the TAC; and (3) is compact and easy to handle, minimizes blood loss from sampling, and delay and dispersion of the TAC. CD-Well has 36 U-shaped channels. A drop of blood is sampled into the opening of the channel and stored there. After serial sampling is completed, CD-Well is centrifuged and scanned using a flatbed scanner to define the regions of plasma and blood cells. The length measured is converted to volume because the channels have a precise and uniform cross section. Then, CD-Well is exposed to an imaging plate to measure radioactivity. Finally, radioactivity concentrations are computed. We evaluated the performance of CD-Well in in vitro measurement and in vivo (18)F-fluorodeoxyglucose and [(11)C]2-carbomethoxy-3β-(4-fluorophenyl) tropane studies. In in vitro evaluation, per cent differences (mean±SE) from manual measurement were 4.4±3.6% for whole blood and 4.0±3.5% for plasma across the typical range of radioactivity measured in mouse dynamic study. In in vivo studies, reasonable TACs were obtained. The peaks were captured well, and the time courses coincided well with the TAC derived from PET imaging of the heart chamber. The total blood loss was less than 200 µL, which had no physiological effect on the mice. CD-Well demonstrates satisfactory performance, and is useful for mouse PET dynamic study.

  14. Measurement of concentrations of whole blood levels of choline, betaine, and dimethylglycine and their relations to plasma levels.

    Science.gov (United States)

    Awwad, Hussain Mohamad; Kirsch, Susanne H; Geisel, Juergen; Obeid, Rima

    2014-04-15

    We aimed at developing a method for the measurement of choline and its metabolites in whole blood (WB). After an extraction step, quantification of choline, betaine, and dimethylglycine (DMG) was performed using ultra performance liquid chromatography tandem mass spectrometry (UPLC-MS/MS). Plasma and WB metabolites were evaluated in a group of 61 elderly people. The calibration curves were linear (r(2)>0.997) for all compounds. The inter- and intra-assay coefficients of variation for all analytes were 90% and the relative matrix effect were ≤4.0%. The median concentrations of choline, betaine, and DMG were 11.3, 27.8, and 5.9μmol/L in plasma and 66.6, 165, and 13.7μmol/L in WB, respectively. There were positive correlations between WB and plasma markers; for choline (r=0.42), betaine (r=0.61), and DMG (r=0.56) (all p≤0.001). The concentrations of betaine in WB and plasma were significantly higher in men than in women. The concentrations of WB choline and DMG did not differ significantly according to sex. In conclusion, we have established a reliable method for measuring choline metabolites in WB. The concentrations of WB choline, betaine, and DMG seem to reflect intracellular concentrations of these metabolites. Copyright © 2014 Elsevier B.V. All rights reserved.

  15. Influence of peripheral blood hemoglobin concentration on the result of radiotherapy for nasopharyngeal carcinoma

    International Nuclear Information System (INIS)

    He Beiwa; Zhang Guofen; Zhao Yutian; Wang Zhenwu; Xu Min; Hu Yulin

    2002-01-01

    Objective: To determine the influence of peripheral blood hemoglobin concentration on the radiotherapy result of nasopharyngeal carcinoma (NPC). Methods: From January 1989 to December 1998, 304 patients with pathologically confirmed NPC received radical radiation. There were 209 males and 95 females. The ages ranged from 16 to 77 years with a median of 42. All patients were irradiated by 60 Co or 6 MV external beam with a total dose of 64 - 76 Gy for the primary tumor and 46 - 77 Gy for the cervical lymph nodes. The peripheral blood hemoglobin concentration for all patients was measured before, during and after radiotherapy. These patients were divided into three groups according to the peripheral blood hemoglobin concentration before radiotherapy: anemia ( 160 g/L), and into two groups according to the change in the peripheral blood hemoglobin concentration during radiotherapy as increased and decreased groups. Results: All patients were followed with a follow-up rate of 90.5%. The peripheral blood hemoglobin concentration had a significant effect on the survival of NPC patients. Its decrease or increase during radiotherapy affected the survival and local control rates of NPC patients. Conclusions: The change of peripheral hemoglobin concentration affecting the oxygen content in the blood, can influence the local control and survival rates of NPC patients. Increase results in higher survival

  16. Serum selenium concentration in maternal and umbilical cord blood. Relation to course and outcome of pregnancy

    DEFF Research Database (Denmark)

    Bro, S; Berendtsen, H; Nørgaard, J

    1988-01-01

    The present knowledge of the role of selenium in human fetal and neonatal development is sparse. In this study we measured serum selenium concentrations in maternal and umbilical cord blood from 500 Danish mothers at delivery, looking for a relationship between various maternal and fetal complica......The present knowledge of the role of selenium in human fetal and neonatal development is sparse. In this study we measured serum selenium concentrations in maternal and umbilical cord blood from 500 Danish mothers at delivery, looking for a relationship between various maternal and fetal...... complications and selenium values. In mothers with uncomplicated pregnancies and deliveries serum selenium concentrations were 0.84 +/- 0.19 mumol/l (mean +/- SD), whereas in cord blood from full-term babies born adequate for gestational age and with no malformations serum selenium concentrations were 0...

  17. The determination of chromium-50 in human blood and its utilization for blood volume measurements

    International Nuclear Information System (INIS)

    Zeisler, R.; Young, I.

    1986-01-01

    Possible relationships between insufficient blood volume increases during pregnancy and infant mortality could be established with an adequate measurement procedure. An accurate and precise technique for blood volume measurements has been found in the isotope dilution technique using chromium-51 as a label for red blood cells. However, in a study involving pregnant women, only stable isotopes can be used for labeling. Stable chromium-50 can be determined in total blood samples before and after dilution experiments by neutron activation analysis (NAA) or mass spectrometry. However, both techniques may be affected by insufficient sensitivity and contamination problems at the inherently low natural chromium concentrations to be measured in the blood. NAA procedures involving irradiations with highly thermalized neutrons at a fluence rate of 2x10 13 n/cm 2 xs and low background gamma spectrometry are applied to the analysis of total blood. Natural levels of chromium-50 in human and animal blood have been found to be <0.1 ng/mL; i.e., total chromium levels of <3 ng/mL. Based on the NAA procedure, a new approach to the blood volume measurement via chromium-50 isotope dilution has been developed which utilizes the ratio of the induced activities of chromium-51 to the iron-59 in three blood samples taken from each individual, namely blank, labeled and diluted labeled blood. (author)

  18. Respiratory ammonia output and blood ammonia concentration during incremental exercise

    NARCIS (Netherlands)

    Ament, W; Huizenga, [No Value; Kort, E; van der Mark, TW; Grevink, RG; Verkerke, GJ

    The aim of this study was to investigate whether the increase of ammonia concentration and lactate concentration in blood was accompanied by an increased expiration of ammonia during graded exercise. Eleven healthy subjects performed an incremental cycle ergometer test. Blood ammonia, blood lactate

  19. Single-cell measurement of red blood cell oxygen affinity.

    Science.gov (United States)

    Di Caprio, Giuseppe; Stokes, Chris; Higgins, John M; Schonbrun, Ethan

    2015-08-11

    Oxygen is transported throughout the body by hemoglobin (Hb) in red blood cells (RBCs). Although the oxygen affinity of blood is well-understood and routinely assessed in patients by pulse oximetry, variability at the single-cell level has not been previously measured. In contrast, single-cell measurements of RBC volume and Hb concentration are taken millions of times per day by clinical hematology analyzers, and they are important factors in determining the health of the hematologic system. To better understand the variability and determinants of oxygen affinity on a cellular level, we have developed a system that quantifies the oxygen saturation, cell volume, and Hb concentration for individual RBCs in high throughput. We find that the variability in single-cell saturation peaks at an oxygen partial pressure of 2.9%, which corresponds to the maximum slope of the oxygen-Hb dissociation curve. In addition, single-cell oxygen affinity is positively correlated with Hb concentration but independent of osmolarity, which suggests variation in the Hb to 2,3-diphosphoglycerate (2-3 DPG) ratio on a cellular level. By quantifying the functional behavior of a cellular population, our system adds a dimension to blood cell analysis and other measurements of single-cell variability.

  20. Relationship between maternal sodium intake and blood lead concentration during pregnancy.

    Science.gov (United States)

    Lee, Yo A; Hwang, Ji-Yun; Kim, Hyesook; Kim, Ki Nam; Ha, Eun-Hee; Park, Hyesook; Ha, Mina; Kim, Yangho; Hong, Yun-Chul; Chang, Namsoo

    2013-03-14

    Pb is released from bone stores during pregnancy, which constitutes a period of increased bone resorption. A high Na intake has been found to be negatively associated with Ca and adversely associated with bone metabolism. It is possible that a high Na intake during pregnancy increases the blood Pb concentration; however, no previous study has reported on the relationship between Na intake and blood Pb concentration. We thus have investigated this relationship between Na intake and blood Pb concentrations, and examined whether this relationship differs with Ca intake in pregnant Korean women. Blood Pb concentrations were analysed in 1090 pregnant women at mid-pregnancy. Dietary intakes during mid-pregnancy were estimated by a 24 h recall method covering the use of dietary supplements. Blood Pb concentrations in whole-blood samples were analysed using graphite furnace atomic absorption spectrophotometry. Multiple regression analysis performed after adjustment for covariates revealed that maternal Na intake was positively associated with blood Pb concentration during pregnancy, but only when Ca intake was below the estimated average requirement for pregnant Korean women (P= 0·001). The findings of the present study suggest that blood Pb concentration during pregnancy could be minimised by dietary recommendations that include decreased Na and increased Ca intakes.

  1. Maternal adiposity and maternal and cord blood concentrations of vitamin D [25(OHD3

    Directory of Open Access Journals (Sweden)

    Fernanda F.A. Simões

    2016-10-01

    Full Text Available Obesity is associated with lower concentrations of vitamin D [25(OHD3] in children, adolescents and adults, but it remains unclear whether maternal adiposity influences maternal and foetal concentrations of this vitamin. The objective of this cross-sectional study was to assess the relationship between maternal adiposity and maternal and cord blood concentrations of vitamin D. It involved 101 mother–newborn pairs from a public maternity in Sao Paulo city, Brazil. Demographic, socioeconomic and obstetric data, as well as anthropometry, physical activity and vitamin D supplementation during pregnancy, were investigated. Maternal adiposity was assessed by bioelectrical impedance. Maternal and cord blood concentrations of vitamin D were measured by high-performance liquid chromatography. Two multiple linear regression models that included maternal and cord blood vitamin D concentrations as outcomes and maternal adiposity as independent variable were used. No association was observed between maternal adiposity and maternal or cord blood concentrations of vitamin D. Maternal vitamin D concentration was associated with race, physical activity and vitamin D supplementation (adj. R2 = 0.74. Cord blood vitamin D concentration was associated with maternal vitamin D concentration (adj. R2 = 0.24. Although fat mass quantification is important to understand vitamin D status during all stages of life, this may not be true in pregnancy as race, vitamin D supplementation and physical activity appeared to be more relevant to vitamin D status. Understanding vitamin D metabolism in pregnancy may elucidate how or if adiposity influences maternal vitamin D status and how it impacts vitamin D transport to the foetus.

  2. Emergency transfusion of patients with unknown blood type with blood group O Rhesus D positive red blood cell concentrates: a prospective, single-centre, observational study.

    Science.gov (United States)

    Selleng, Kathleen; Jenichen, Gregor; Denker, Kathrin; Selleng, Sixten; Müllejans, Bernd; Greinacher, Andreas

    2017-05-01

    Emergency patients with unknown blood type usually receive O Rhesus D negative (RhD-) red blood cell concentrates until their blood group is determined to prevent RhD+ related adverse transfusion reactions. As 85% of individuals are RhD+, this consumption of O RhD- red blood cell concentrates contributes to shortages of O RhD- red blood cell concentrates, sometimes forcing transfusion of known RhD- patients with RhD+ red blood cell concentrates. Here we report the outcome of this transfusion policy transfusing all emergency patients with unknown blood type with O RhD+ red blood cell concentrates. In this prospective single-centre observational study done between Jan 1, 2001, and Dec 31, 2015, we assessed all consecutive RhD- patients at the University Medicine Greifswald who received RhD+ red blood cell concentrates (emergency patients with unknown blood type; and RhD- patients receiving RhD+ red blood cell concentrates during RhD- red blood cell concentrate shortages). No patients were excluded. The primary endpoint was anti-D allo-immunisation at 2 months follow-up or later. Patients were followed up and tested for immunisation against red blood cell antigens using the direct antiglobulin test and an antibody screen every 3-5 days for 4 weeks or until death, or hospital discharge. Surviving patients were screened for development of anti-D antibodies for up to 12 months (at the predefined timepoints 2, 3, 6, and 12 months) after RhD+ red blood cell transfusion. 437 emergency patients, of whom 85 (20%) were RhD-, received 2836 RhD+ red blood cell concentrates. The overall risk of inducing anti-D antibodies (in all 437 recipients) was 17 (4%, 95% CI 2·44-6·14) of 437 (assuming all patients lost to follow-up developed anti-D allo-immunisation). During this period, 110 known RhD- patients received RhD+ red blood cell concentrates during RhD- red blood cell concentrate shortages. Of these, 29 (26%; 95% CI 19·0-35·3) developed anti-D allo-immunisation (assuming all

  3. Postmortem Quetiapine Reference Concentrations in Brain and Blood

    DEFF Research Database (Denmark)

    Skov, Louise; Johansen, Sys Stybe; Linnet, Kristian

    2015-01-01

    and related to concentrations in postmortem blood. For cases, where quetiapine was unrelated to the cause of death (N 5 36), the 10–90 percentiles for quetiapine concentrations in brain tissue were 0.030 – 1.54 mg/kg (median 0.48 mg/kg, mean 0.79 mg/kg). Corresponding blood 10 –90 percentile values were 0.......007 – 0.39 mg/kg (median 0.15 mg/kg, mean 0.19 mg/kg), giving brain –blood ratio 10 –90 percentiles of 2.31 – 6.54 (median 3.87, mean 4.32). Both correspond well to the limited amount of data found in the literature. For cases where quetiapine was a contributing factor to death (N 5 5), the median value......Brain tissue is a useful alternative to blood in postmortem forensic investigations, but scarcity of information on reference concentrations in brain tissue makes interpretation challenging. Here we present a study of 43 cases where the antipsychotic drug quetiapine was quantified in brain tissue...

  4. CSF and blood oxytocin concentration changes following intranasal delivery in macaque.

    Directory of Open Access Journals (Sweden)

    Olga Dal Monte

    Full Text Available Oxytocin (OT in the central nervous system (CNS influences social cognition and behavior, making it a candidate for treating clinical disorders such as schizophrenia and autism. Intranasal administration has been proposed as a possible route of delivery to the CNS for molecules like OT. While intranasal administration of OT influences social cognition and behavior, it is not well established whether this is an effective means for delivering OT to CNS targets. We administered OT or its vehicle (saline to 15 primates (Macaca mulatta, using either intranasal spray or a nebulizer, and measured OT concentration changes in the cerebral spinal fluid (CSF and in blood. All subjects received both delivery methods and both drug conditions. Baseline samples of blood and CSF were taken immediately before drug administration. Blood was collected every 10 minutes after administration for 40 minutes and CSF was collected once post-delivery, at the 40 minutes time point. We found that intranasal administration of exogenous OT increased concentrations in both CSF and plasma compared to saline. Both delivery methods resulted in similar elevations of OT concentration in CSF, while the changes in plasma OT concentration were greater after nasal spray compared to nebulizer. In conclusion our study provides evidence that both nebulizer and nasal spray OT administration can elevate CSF OT levels.

  5. Blood Concentrations of Cadmium and Lead in Multiple Sclerosis Patients from Iran.

    Science.gov (United States)

    Aliomrani, Mehdi; Sahraian, Mohammad Ali; Shirkhanloo, Hamid; Sharifzadeh, Mohammad; Khoshayand, Mohammad Reza; Ghahremani, Mohammad Hossein

    2016-01-01

    Since industrial revolution heavy metals such as lead (Pb) and cadmium (Cd) have been extensively dispersed in environment which, unknown biological effects and prolong biological half-life make them as a major hazard to human health. In addition, the sharp increase in Multiple sclerosis incidence rateshas been recorded in Iran. The propose of this study was to measuring blood lead and cadmium concentration and their correlation with smoking habit in a group of 69 RRMS patients and 74 age/gender-matched healthy individuals resident in Tehran as most polluted city in Iran. All subjects were interviewed regarding age, medical history, possible chemical exposure, acute or chronic diseases, smoking and dietary habits. Blood Pb and Cd levels were measured by double beam GBC plus 932 atomic absorption spectrometer. Our result indicated a significant difference in Cd level (p = 0.006) in which, MS patients had higher blood concentration (1.82 ± 0.13 μg/L) in comparison with healthy individuals (1.47 ± 0.11 μg/L). A comparable blood Cd level to similar recent study (1.78 µg/L vs.1.82 µg/L) was observed. With respect to Pb there was no significant difference between cases and controls, however the geometric means of blood Pb concentration were considerably higher in males than in females in MS patients (57.1 ± 33.7 μg/L vs . 36.7 ± 21.9 μg/L. P = 0.02). Taking into consideration tobacco smoking, an elevated contents of each metal were observed in smoker subjects (p<0.0001). A significant correlation between cigarette smoking and risk of multiple sclerosis was shown before. Thus, high level of Cd in smokers might affect the susceptibility to multiple sclerosis and could increase the risk of disease development.

  6. Determination of blood cell subtype concentrations from frozen whole blood samples using TruCount beads.

    Science.gov (United States)

    Langenskiöld, Cecilia; Mellgren, Karin; Abrahamsson, Jonas; Bemark, Mats

    2016-06-24

    In many studies it would be advantageous if blood samples could be collected and analyzed using flow cytometry at a later stage. Ideally, sample collection should involve little hands-on time, allow for long-term storage, and minimally influence the samples. Here we establish a flow cytometry antibody panel that can be used to determine granulocytes, monocytes, and lymphocyte subset concentrations in fresh and frozen whole blood using TruCount technology. The panel can be used on fresh whole-blood samples as well as whole-blood samples that have been frozen after mixing with 10% DMSO. Concentrations in frozen and fresh sample is highly correlated both when frozen within 4 h and the day after collection (r ≥ 0.98), and the estimated concentration in frozen samples was between 91 and 94% of that in fresh samples for all cell types. Using this method whole-blood samples can be frozen using a simple preparation method, and stored long-term before accurate determination of cell concentration. This allows for standardized analysis of the samples at a reference laboratory in multi-center studies. © 2016 International Clinical Cytometry Society. © 2016 International Clinical Cytometry Society.

  7. Measurements of total lead concentrations and of lead isotope ratios in whole blood by use of inductively coupled plasma source mass spectrometry

    International Nuclear Information System (INIS)

    Delves, H.T.; Campbell, M.J.

    1988-01-01

    Methods are described for the accurate and precise determination of total lead and its isotopic composition in whole blood using inductively coupled plasma source mass spectrometry (ICP-MS). Sensitivities of up to 3 x 10 6 counts s -1 for 208 Pb at a total lead concentration of 5 μmol l -1 (1 μg ml -1 ) enabled total blood lead levels to be measured in 4 min per sample, with a detection limit of 0.072 μmol l -1 (15 μg l -1 ). The agreement between ICP-MS and atomic absorption spectrometry (AAS) for this analysis was excellent: ICP-MS 0.996 x AAS -0.0165 μmol l -1 ; r 0.994. Isotope ratio measurements required 15 min to achieve the required accuracy and precision both of which were generally better than 0.5% for 206 Pb: 207 Pb and 208 Pb: 206 Pb isotopic lead ratios. The ICP-MS data for these ratios in ten quality control blood specimens has a mean bias relative to isotope dilution mass spectrometry of -0.412% for 206 Pb: 207 Pb ratios and of +0.055% for the 208 Pb: 206 Pb ratios. This level of accuracy and that of the total blood lead measurements is sufficient to permit application of these ICP-MS methods to environmental studies. (author)

  8. Photoacoustic determination of glucose concentration in whole blood by a near-infrared laser diode

    Science.gov (United States)

    Zhao, Zuomin; Myllylae, Risto A.

    2001-06-01

    The near-infrared photoacoustic technique is recognized as a potential method for the non-invasive determination of human glucose, because near-infrared light can incident a few millimeters into human tissue, where it produces an acoustic wave capable of carrying information about the composition of the tissue. This paper demonstrates a photoacoustic glucose measurement in a blood sample as a step toward a non-invasive measurement. The experimental apparatus consists of a near-infrared laser diode operating with 4 micro joules pulse energy at 905 nm, a roller pump connected to a silicon plastic tube and a cuvette for circulating the blood sample. In addition, the apparatus comprises a PZT piezoelectric transducer integrated with a battery-powered preamplifier to receive the photoacoustic signal. During the experiment, a glucose solution is mixed into a human blood sample to change its concentration. Although the absorption coefficient of glucose is much smaller than that of blood in the near-infrared region, the osmotic and hydrophilic properties of glucose decrease the reduced scattering coefficient of blood caused by the dissolved glucose surrounding the blood cells. This changes the distribution of the absorbed optical energy in blood, which, in turn, produces a change in the photoacoustic signal. Our experiment demonstrates that signal amplitudes in fresh and stored blood samples in crease about 7% and 10%, respectively, when the glucose concentration reaches the upper limit of the physiological region (500 mg/dl).

  9. Effect of exercise on erythrocyte count and blood activity concentration after technetium-99m in vivo red blood cell labeling

    International Nuclear Information System (INIS)

    Konstom, M.A.; Tu'meh, S.; Wynne, J.; Beck, J.R.; Kozlowski, J.; Holman, B.L.

    1982-01-01

    The effects of exercise on blood radiotracer concentration after technetium-99m in vivo red blood cell labeling was studied. After red blood cell labeling, 13 subjects underwent maximal supine bicycle exercise. Radioactivity, analyzed with a well counter, was measured in heparinized venous blood samples drawn at rest and during peak exercise. Changes in activity were compared with changes in erythrocyte count. Activity and erythrocyte counts increased in erythrocyte count (r=0.78), but did not correlate with either duration of exercise or maximal heart rate. Twenty minutes after termination of exercise, activity and erythrocyte count had decreased from peak exercise values but remained higher than preexercise values. In nine nonexercised control subjects, samples drawn 20 minutes apart showed no change in activity or in erythrocyte count. It was concluded that exercise increases blood activity, primarily because of an increase in erythrocyte count. During radionuclide ventriculography, blood activity must be measured before and after any intervention, particularly exercise, before a change in left ventricular activity can be attributed to a change in left ventricular volume

  10. Concentrations of Water-Soluble Vitamins in Blood and Urinary Excretion in Patients with Diabetes Mellitus

    Directory of Open Access Journals (Sweden)

    Hiromi Iwakawa

    2016-01-01

    Full Text Available We examined the concentrations of water-soluble vitamins in blood and urinary excretion of 22 patients with type 2 diabetes mellitus (type 2DM and 20 healthy control participants. Macronutrient and vitamin intakes of type 2DM subjects were measured using a weighed food record method. Control participants consumed a semipurified diet for eight days. Multiple linear regression models were used to determine whether significant differences existed in vitamin concentrations in blood independent of age, sex, and other confounding factors. Concentrations of vitamins B2, B6, C, niacin, and folate in blood were significantly lower in type 2DM subjects than in controls, independent of confounding factors. Renal clearances of vitamins B6, C, niacin, and folate were significantly higher in type 2DM subjects than in controls. In conclusion, concentrations of vitamins B2, B6, C, niacin, and folate in blood were significantly lower in type 2DM subjects than in controls, independent of confounding factors; based on the evidence of increased urinary clearance of these vitamins, the lower levels were likely due to impaired reabsorption processes.

  11. Concentrations of Water-Soluble Vitamins in Blood and Urinary Excretion in Patients with Diabetes Mellitus.

    Science.gov (United States)

    Iwakawa, Hiromi; Nakamura, Yasuyuki; Fukui, Tomiho; Fukuwatari, Tsutomu; Ugi, Satoshi; Maegawa, Hiroshi; Doi, Yukio; Shibata, Katsumi

    2016-01-01

    We examined the concentrations of water-soluble vitamins in blood and urinary excretion of 22 patients with type 2 diabetes mellitus (type 2DM) and 20 healthy control participants. Macronutrient and vitamin intakes of type 2DM subjects were measured using a weighed food record method. Control participants consumed a semipurified diet for eight days. Multiple linear regression models were used to determine whether significant differences existed in vitamin concentrations in blood independent of age, sex, and other confounding factors. Concentrations of vitamins B2, B6, C, niacin, and folate in blood were significantly lower in type 2DM subjects than in controls, independent of confounding factors. Renal clearances of vitamins B6, C, niacin, and folate were significantly higher in type 2DM subjects than in controls. In conclusion, concentrations of vitamins B2, B6, C, niacin, and folate in blood were significantly lower in type 2DM subjects than in controls, independent of confounding factors; based on the evidence of increased urinary clearance of these vitamins, the lower levels were likely due to impaired reabsorption processes.

  12. Carbon monoxide concentration in donated blood: relation to cigarette smoking and other sources.

    Science.gov (United States)

    Aberg, Anna-Maja; Sojka, Birgitta Nilsson; Winsö, Ola; Abrahamsson, Pernilla; Johansson, Göran; Larsson, Jan Erik

    2009-02-01

    Carbon monoxide (CO) is normally present in the human body due to endogenous production of CO. CO can also be inhaled by exposure to external sources such as cigarette smoke, car exhaust, and fire. The purpose of this study was to investigate CO concentrations in blood from 410 blood donors at the blood center in Umeå, Sweden. To further evaluate the effects of cigarette smoking on CO concentrations, the elimination time for CO was examined in six volunteer smokers after a smoked cigarette. Blood samples from whole blood donors were obtained during the blood center's routine operation. In connection with blood donations, demographic and behavioral data were collected from the donors. The CO concentration was determined using gas chromatography. The majority of blood donors had approximately the same CO concentration (mean, 84.5 micromol/L). In 6 percent of the samples, the concentrations were higher than 130 micromol per L. The highest CO concentration was 561 micromol per L. The main source for these high CO concentrations appeared to be cigarette smoking. In the volunteer smokers, the elimination time after a smoked cigarette varied significantly, with elimination half-lives from 4.7 to 8.4 hours. These results show that blood bank red blood cell bags may have CO concentrations above the physiologic level. The time interval between cigarette smoking and blood donation seems to be a particularly important factor for elevated CO concentrations.

  13. Elements concentrations and relationship of whole blood and urine in 40 identical adult men in China

    International Nuclear Information System (INIS)

    Zhu, H.D.; Wu, Q; Fan, T.J.; Liu, Q.F; Wang, J.Y; Wang, N.F; Liu, H.S; Wang, X.Y; Ou-Yang, L.; Liu, Y.Q.; Xie, Q.

    2008-01-01

    Objective: To determine elemental concentrations in whole blood and 24 hr. urine of identical adult men, relative daily urinary excretion and verify relationship between both of concentrations in the blood and urine. Methods: During the same time as sampling organ or tissue samples from autopsy, whole blood and 24 hr. urine samples of identical subjects were obtained from each of 10 healthy adult male volunteers, living in 4 areas with different dietary types in China. The concentrations of 56 elements in both the two kinds of samples were analyzed by using ICP-MS as the principal, assisted with ICP-AES as well GFAAS techniques and necessary QC measures. The concentrations of urinary creatinine in the urine samples were determined by using spectrophotometric method. Results: Concentrations of both the 56 elements in these whole blood and urine samples of identical subjects and urinary creatinine and related daily urinary excretions were obtained. Conclusion: This research obtained the new data on both concentrations of these elements in whole blood and urine samples of identical subjects and their daily urinary excretions for the first time in China. These results have provided preliminary basis for understanding concentrations of these elements in the whole blood, daily urinary excretions of identical subjects as well their differences for different areas, and developing relative background values and parameters for Chinese Reference Man. Furthermore, the obtained results have been compared with both internal and external literature data and discussed. (author)

  14. The boron concentration measurement by the prompt gamma-ray analysis device at JRR-4

    International Nuclear Information System (INIS)

    Hori, N.; Torii, Y.; Yamamoto, K.; Kishi, T.; Takada, J.

    2000-01-01

    In determining the dose for BNCT, it is important to measure the boron concentration in blood as well as the thermal neutron fluence. To attain an accurate measurement of the boron concentration in the whole blood at about 30 ppm, the Prompt Gamma-ray Analysis (PGA) is adopted to enable the measurement with a high degree of accuracy in short time, since the chemical analysis technique has some difficulties on it. In order to install the PGA device in a swimming pool type research reactor JRR-4, the super-mirror for obtaining the necessary neutron flux in the space over the pool surface was perpendicularly placed, because the reactor had no horizontal experiment tube for this kind of use. As the accurate measurement of the boron concentration in whole blood using PGA is enabled herewith, the first medical irradiation for BNCT at JRR-4 was carried out on October 25, 1999. (author)

  15. Altering plasma sodium concentration rapidly changes blood pressure during haemodialysis.

    Science.gov (United States)

    Suckling, Rebecca J; Swift, Pauline A; He, Feng J; Markandu, Nirmala D; MacGregor, Graham A

    2013-08-01

    Plasma sodium is increased following each meal containing salt. There is an increasing interest in the effects of plasma sodium concentration, and it has been suggested that it may have direct effects on blood pressure (BP) and possibly influences endothelial function. Experimental increases of plasma sodium concentration rapidly raise BP even when extracellular volume falls. Ten patients with end-stage renal failure established on haemodialysis were studied during the first 2 h of dialysis without fluid removal during this period. They were randomized to receive haemodialysis with (i) dialysate sodium concentration prescribed to 135 mmol/L and (ii) 145 mmol/L in random order in a prospective, single-blinded crossover study. BP measurements and blood samples were taken every 30 min. Pre-dialysis sitting BP was 137/76 ± 7/3 mmHg. Lower dialysate sodium concentration (135 mmol/L) reduced plasma sodium concentration [139.49 ± 0.67 to 135.94 ± 0.52 mmol/L (P area under the curve (AUC) 15823.50 ± 777.15 (mmHg)min] compared with 145 mmol/L [AUC 17018.20 ± 1102.17 (mmHg)min], mean difference 1194.70 ± 488.41 (mmHg)min, P < 0.05. There was a significant positive relationship between change in plasma sodium concentration and change in systolic BP. This direct relationship suggests that a fall of 1 mmol/L in plasma sodium concentration would be associated with a 1.7 mmHg reduction in systolic BP (P < 0.05). The potential mechanism for the increase in BP seen with salt intake may be through small but significant changes in plasma sodium concentration.

  16. Characterization of blood donors with high haemoglobin concentration

    DEFF Research Database (Denmark)

    Magnussen, K; Hasselbalch, H C; Ullum, H

    2013-01-01

    Background and Objectives  The literature contains little on the prevalence and causes of high predonation haemoglobin levels among blood donors. This study aimed to characterize and develop an algorithm to manage would-be donors with polycythaemia. Materials and Methods  Between November 2009...... and November 2011, we offered haematology consultations to blood donors with repeated haemoglobin concentration (Hb) above the WHO limit for polycythaemia vera (PV) (10·2 and 11·5 mm/16·5 and 18·5 g/dl for women and men, respectively). Investigation of such donors included Hb, haematocrit, mean cell volume......, erythropoietin, ferritin, platelet count and leucocyte count, JAK2 V617 and JAK2 exon12 analysis, as well as other routine measurements. Results  Among 46 such donors, 39 had a history of smoking, which contributes to erythrocytosis. Two had PV, five had severe hypertension, one of them because of renal artery...

  17. Correlation between airborne manganese concentration at the workstations in the iron foundry and manganese concentration in workers’ blood

    Directory of Open Access Journals (Sweden)

    Seyedtaghi Mirmohammadi

    2017-08-01

    Full Text Available Background: Manganese (Mn used as raw material for melting process in the ferrous foundry is considered as hazardous neurotoxic substance because it accumulates in the central nervous system and may cause neurological disorders. The furnace-men and melting department workers are potentially exposed to manganese particles or fume in the workplace. The objective of the research has been to investigate the sources and levels of manganese exposure in the foundry by correlation of blood-manganese (B-Mn and air-manganese (air-Mn measurement. Material and Methods: Air-Mn and Mn of blood serum were measured involving workers who worked in a big-sized foundry during 1 year. The standard method of the Occupational Safety and Health Administration (OSHA ID-121 was used for air and blood assessment and atomic absorption spectroscopy (AAS was carried out for air and blood sample analysis. Results: The air sampling results have revealed that there is a high exposure to manganese (4.5 mg/m3 in the workplace as compared to the National Institute for Occupational Safety and Health’s (NIOSH time weighted average (the reference time-weighted average (TWA = 1 mg/m3. The average blood serum Mn concentration was 2.745 μg/l for subjects working for shorter than 3 months and 274.85 μg/l for subjects working 3–12 months. Conclusions: Against the research hypothesis there was no correlation between the air-Mn concentration and the B-Mn (serum level of manganese in the serum of the exposed subjects. It may be due to short time of air sampling of manganese airborne particles, and a real-time monitoring of airborne manganese particles is suggested for any future study. Med Pr 2017;68(4:449–458

  18. Evaluation of the correlation between transcutaneous measurement andconcentration ofbilirubin inthe blood serum ofa newborn

    Directory of Open Access Journals (Sweden)

    Małgorzata Morawiecka-Pietrzak

    2016-09-01

    Full Text Available Aim: Due to the potential toxicity of high concentrations of bilirubin, newborns are monitored in terms of the potential emergence of a group at risk of the development of severe hyperbilirubinaemia and, rarely, encephalopathy and kernicterus. The transcutaneous measurement of bilirubin, as a non-invasive method, is applied in neonatal centres. The paper presents an evaluation of the correlation between the transcutaneous measurement and the concentration of bilirubin in the blood serum of a newborn, taking into consideration the reduction of the necessity to carry out blood tests related to the transcutaneous measurement. Material and method: The analysis comprised 1,076 medical histories of newborns hospitalised at the Department of Neonatology of the Municipal Hospital in Zabrze in the period from 1 January to 31 December 2013 (a primary referral centre. The inclusion criteria for the study were: performing a simultaneous transcutaneous measurement and a blood serum concentration measurement of bilirubin, gestational age ≥35 Hbd and birth weight >2,500 g. 272 children were qualified for the study. Results: Boys constituted 51.7%, and girls 48.3% of the research group. The mean gestational age was 38.7 Hbd and the mean birth weight was 3,323.4 g; 67.8% of the children were born by natural labour and 32.2% – by caesarean section. The mean Apgar score in the 5th minute was 9.8 points. The measurement of the concentration of bilirubin was performed on average on the 3.9 day of life. The mean transcutaneous measurement was 9.67 mg% (2.7–17.2 mg% and the mean concentration of bilirubin in the blood serum was 13.18 mg% (7.0–19.8 mg%; the difference was 3.5 mg% (p < 0.0001. A statistically significant positive correlation was found between the concentrations of bilirubin obtained in the transcutaneous measurement and the concentrations in the blood serum (according to Spearman, r

  19. Cancer and blood concentrations of the comutagen harmane in essential tremor.

    Science.gov (United States)

    Louis, Elan D; Pellegrino, Kathryn M; Factor-Litvak, Pam; Rios, Eileen; Jiang, Wendy; Henchcliffe, Claire; Zheng, Wei

    2008-09-15

    Blood concentrations of harmane, a tremor-producing neurotoxin, are elevated in essential tremor (ET). Harmane is also a comutagen. Using a case-control design, we compared the prevalence of cancer in ET cases vs. controls, and determined whether blood harmane concentrations are elevated among ET cases with cancer. 66/267 (24.7%) ET cases vs. 55/331 (16.6%) controls had cancer (adjusted OR 1.52, 95% CI 1.01-2.30, P = 0.04). Among specific cancer types, colon cancer was more prevalent in ET cases than controls (2.6% vs. 0.6%, P = 0.04). Log blood harmane concentration was higher in ET cases vs. controls (P = 0.02) and in participants with vs. without cancer (P = 0.02). Log blood harmane concentration was highest in ET cases with cancer when compared with other groups (P = 0.009). These links between cancer and ET and between high blood harmane and cancer in ET deserve further study. (c) 2007 Movement Disorder Society.

  20. Anthroposophic lifestyle influences the concentration of metals in placenta and cord blood

    International Nuclear Information System (INIS)

    Fagerstedt, Sara; Kippler, Maria; Scheynius, Annika; Gutzeit, Cindy; Mie, Axel; Alm, Johan; Vahter, Marie

    2015-01-01

    Allergic diseases develop in genetically susceptible individuals in a complex interplay with the environment, usually early in life. We have previously shown that the anthroposophic lifestyle is associated with reduced risk of allergic disease in children, but details on the influencing environmental factors are largely unknown. This study aims to elucidate if anthroposophic lifestyle influences fetal exposure to selected toxic and essential elements. Randomly selected non-smoking mothers with (n=40) and without (n=40) anthroposophic lifestyle from the prospective birth cohort ALADDIN were included. Concentrations of 12 toxic and essential elements were analyzed in full term placentas and in the erythrocyte fractions of maternal peripheral blood and of umbilical cord blood, using inductively coupled plasma mass spectrometry. Cadmium concentrations in maternal blood and placenta were significantly higher in mothers with an anthroposophic lifestyle (p<0.001), while concentrations in cord blood were generally low, irrespective of lifestyle. Cobalt concentrations were higher in both maternal blood, placenta and cord blood in the anthroposophic group. Lead concentrations were higher in maternal blood and cord blood, but not placenta, of mothers with anthroposophic lifestyle. Analysis of covariance, including lifestyle, parity, maternal age, gestational age, vegetarian diet, use of herbal medicine and occupation in the model, showed that mainly the anthroposophic lifestyle was significantly associated with cadmium concentrations. In conclusion, women with an anthroposophic lifestyle had higher concentrations of cadmium, cobalt and lead concentrations. Cadmium concentrations might have been influenced by a diet rich in vegetables and/or low iron status of the mothers. - Highlights: • Toxic elements in mother–newborn pairs in relation to anthroposophic lifestyle. • Anthroposophic lifestyle was associated with higher levels of cadmium, cobalt and lead. • A diet rich

  1. Anthroposophic lifestyle influences the concentration of metals in placenta and cord blood

    Energy Technology Data Exchange (ETDEWEB)

    Fagerstedt, Sara [The Department of Clinical Science and Education, Södersjukhuset, Karolinska Institutet, Stockholm (Sweden); Kippler, Maria [Institute of Environmental Medicine, Karolinska Institutet, Box 210, 171 77 Stockholm (Sweden); Scheynius, Annika; Gutzeit, Cindy [Department of Medicine Solna, Translational Immunology Unit, Karolinska Institutet and University Hospital, Stockholm (Sweden); Mie, Axel [The Department of Clinical Science and Education, Södersjukhuset, Karolinska Institutet, Stockholm (Sweden); Alm, Johan [The Department of Clinical Science and Education, Södersjukhuset, Karolinska Institutet, Stockholm (Sweden); Sachs' Children and Youth Hospital, Södersjukhuset, Stockholm (Sweden); Vahter, Marie, E-mail: marie.vahter@ki.se [Institute of Environmental Medicine, Karolinska Institutet, Box 210, 171 77 Stockholm (Sweden)

    2015-01-15

    Allergic diseases develop in genetically susceptible individuals in a complex interplay with the environment, usually early in life. We have previously shown that the anthroposophic lifestyle is associated with reduced risk of allergic disease in children, but details on the influencing environmental factors are largely unknown. This study aims to elucidate if anthroposophic lifestyle influences fetal exposure to selected toxic and essential elements. Randomly selected non-smoking mothers with (n=40) and without (n=40) anthroposophic lifestyle from the prospective birth cohort ALADDIN were included. Concentrations of 12 toxic and essential elements were analyzed in full term placentas and in the erythrocyte fractions of maternal peripheral blood and of umbilical cord blood, using inductively coupled plasma mass spectrometry. Cadmium concentrations in maternal blood and placenta were significantly higher in mothers with an anthroposophic lifestyle (p<0.001), while concentrations in cord blood were generally low, irrespective of lifestyle. Cobalt concentrations were higher in both maternal blood, placenta and cord blood in the anthroposophic group. Lead concentrations were higher in maternal blood and cord blood, but not placenta, of mothers with anthroposophic lifestyle. Analysis of covariance, including lifestyle, parity, maternal age, gestational age, vegetarian diet, use of herbal medicine and occupation in the model, showed that mainly the anthroposophic lifestyle was significantly associated with cadmium concentrations. In conclusion, women with an anthroposophic lifestyle had higher concentrations of cadmium, cobalt and lead concentrations. Cadmium concentrations might have been influenced by a diet rich in vegetables and/or low iron status of the mothers. - Highlights: • Toxic elements in mother–newborn pairs in relation to anthroposophic lifestyle. • Anthroposophic lifestyle was associated with higher levels of cadmium, cobalt and lead. • A diet rich

  2. Measurement of cyclosporine concentrations in whole blood: HPLC and radioimmunoassay with a specific monoclonal antibody and 3H- or 125I-labeled ligand compared

    International Nuclear Information System (INIS)

    Wolf, B.A.; Daft, M.C.; Koenig, J.W.; Flye, M.W.; Turk, J.W.; Scott, M.G.

    1989-01-01

    We compared cyclosporine concentrations in whole blood as measured by HPLC and by RIA with a monoclonal antibody specific for cyclosporine with 3 H- or 125 I-labeled cyclosporine ligand. The 3 H-RIA kit slightly underestimated cyclosporine concentrations (greater than 600 micrograms/L) in comparison with HPLC. Over a wide range of concentrations, cyclosporine measured with the 125 I-RIA kit correlated well with HPLC (slope = 0.99, n = 301, r = 0.98), observed for samples from recipients of kidney, heart, or liver allografts (respective slopes: 1.01, 0.93, and 1.00). The 125 I-RIA standard curve was linear to 1000 micrograms of cyclosporine per liter. Inter- and intra-assay CVs for 125 I-RIA measurements of cyclosporine were less than or equal to 7%. Evidently, the 125 I-RIA kit involving a monoclonal antibody specific for cyclosporine is equivalent to the HPLC assay and can replace it for therapeutic drug monitoring of cyclosporine therapy

  3. Evaluation of droplet digital PCR for quantification of residual leucocytes in red blood cell concentrates.

    Science.gov (United States)

    Doescher, A; Loges, U; Petershofen, E K; Müller, T H

    2017-11-01

    Enumeration of residual white blood cells in leucoreduced blood components is essential part of quality control. Digital PCR has substantially facilitated quantitative PCR and was thus evaluated for measurements of leucocytes. Target for quantification of leucocytes by digital droplet PCR was the blood group gene RHCE. The SPEF1 gene was added as internal control for the entire assay starting with automated DNA extraction. The sensitivity of the method was determined by serial dilutions of standard samples. Quality control samples were analysed within 24 h, 7 days and 6 months after collection. Routine samples from leucodepleted red blood cell concentrates (n = 150) were evaluated in parallel by flow-cytometry (LeucoCount) and by digital PCR. Digital PCR reliably detected at least 0·4 leucocytes per assay. The mean difference between PCR and flow-cytometric results from 150 units was -0·01 (±1·0). DNA samples were stable for up to at least six months. PCR measurement of leucocytes in samples from plasma and platelet concentrates also provided valid results in a pilot study. Droplet digital PCR to enumerate leucocytes offers an alternative for quality control of leucoreduced blood products. Sensitivity, specificity and reproducibility are comparable to flow-cytometry. The option to collect samples over an extended period of time and the automatization introduce attractive features for routine quality control. © 2017 International Society of Blood Transfusion.

  4. The Cut-off Value of Blood Mercury Concentration in Relation to Insulin Resistance

    Directory of Open Access Journals (Sweden)

    Seok-Hoon Lee

    2017-09-01

    Full Text Available Background : Increased blood mercury concentration is associated with inflammation, and chronic inflammation can cause insulin resistance. We examined the cut-off value of blood mercury in relation to an increased score on the homeostasis model assessment for insulin resistance (HOMA-IR. Methods : We used data from the Korean National Health and Nutrition Examination Survey (2008–2010. Relevant data from 5,184 subjects (2,523 men and 2,661 women were analyzed cross-sectionally. General linear analysis was performed to evaluate the relationship between HOMA-IR score and blood mercury concentration. In addition, we determined the cut-off value of blood mercury concentration in relation to increased HOMA-IR score (> 2.34 using an ROC curve. Results : The mean value of blood mercury concentration in men and women was 5.88 μg/L and 4.11 μg/L, respectively. In men, comparing to the first quartile, HOMA-IR score increased significantly in the third and fourth blood mercury quartiles. In women, however, the increase in HOMA-IR score was not significant. The cut-off value that best represented the association between increased HOMA-IR score and blood mercury concentration in men was found to be 4.71 μg/L. Conclusion : Blood mercury concentration was associated with increased HOMA-IR score in men, and the cut-off value of blood mercury concentration that was correlated with increased HOMA-IR score was around 4.71 μg/L.

  5. Radioimmunoassay for measurement of thyroxine (T4) and triiodothyonine (T3) in blood serum

    International Nuclear Information System (INIS)

    Chopra, I.J.

    1975-01-01

    This invention relates to a highly accurate, rapid and simple estimation of thyroxine (T 4 ) directly from blood serum and also relates to the accurate measurement of triiodo-L-thyronine (T 3 ) directly from blood serum. More specifically, the invention relates to a rapid, specific and reliable radioimmunoassay (RIA) technique for measurement of both T 4 and T 3 in unextracted serum. The method requires very small amounts of serum, e.g., 25 microliters (μl) to measure T 4 concentration in nearly all specimens representing clinical states of eu-, hypo- and hyperthyroidism, and 250 μl to measure T 3 concentrations in specimens representing most clinical states

  6. Outcome prediction value of determination of cord blood ADM concentrations in neonates with perinatal asphyxia events

    International Nuclear Information System (INIS)

    Zhang Shifa; Zhou Mingxiong; Zhang Xinlu

    2006-01-01

    Objective: To investigate the clinical value of determination of cord blood adrenomedullin (ADM) concentration for predicting development of hypoxic ischemic encephalopathy (HIE) in neonates suffered from perinatal asphyxia. Methods: Cord blood plasma ADM concentrations were measured with RIA in 77 full-ferm neonates with perinatal asphyxia and 30 controls. Results: In the 77 neonates with perinatal asphyxia, 32 developed clinical evidence of HIE within 7 days after birth (HIE group) and 45 didn't (non-HIE group). Cord blood plasma ADM concentrations in the HIE group (160.30 ± 41.3pg/ml) were significantly higher than those in the non-HIE group (112.26 ± 22.90 pg/ml) and controls (102.90 ± 19.43pg/ml). The cord blood plasma ADH concentrations in HIE group were also significantly positively correlated with the severity of the disease (r s = 0. 752, P < 0. 01 ). From our data, taking 117.93pg/ml as cut-off value for diagnosis of HIE would result in a sensitivity of 90.63%, specificity of 80%, and accuracy of 84.42%. Conclusion: High level of ADM in cord blood of neonates with perinatal asphyxia (≥117.93pg/ml) would predict development of HIE with a reasonable accuracy. (authors)

  7. Temporal stability of blood lead concentrations in adults exposed only to environmental lead

    Energy Technology Data Exchange (ETDEWEB)

    Delves, H T; Sherlock, J C; Quinn, M J

    1984-08-01

    The temporal stability of blood lead concentrations of 21 health adults (14 men and 7 women) exposed only to environmental lead was assessed by analysis of 253 blood specimens collected serially over periods from 7 to 11 months. The women had lower blood lead concentrations (mean 8.5, range 7.4-10.8 micrograms/100 ml) than did the men (mean 12.2, range 8.6-15.8 micrograms/100 ml). These are within the expected ranges for non-occupationally exposed persons. Blood lead concentrations in the serial specimens from both men and women changed very little over the study period, with standard deviations of less than 0.5 micrograms/100 ml for the majority of individual mean concentrations: for all except low subjects the standard deviations were less than 0.8 micrograms/100 ml. Two subjects showed significant changes in blood lead concentrations during the study. A temporary increase in oral lead intake was identified for one of these subjects. In the absence of substantial changes in lead exposure blood lead levels in adults are remarkably stable and for their environmental monitoring a single blood lead concentration is an excellent biological indicator.

  8. Effect of exercise on erythrocyte count and blood activity concentration after /sup 99m/Tc in vivo red blood cell labeling

    International Nuclear Information System (INIS)

    Konstam, M.A.; Tu'meh, S.; Wynne, J.; Beck, J.R.; Kozlowski, J.; Holman, B.L.

    1982-01-01

    We studied the effect of exercise on blood radiotracer concentration after /sup 99m/Tc in vivo red blood cell labeling. After red blood cell labeling, 13 subjects underwent maximal supine bicycle exercise. Radioactivity, analyzed with a well counter, was measured in heparinized venous blood samples drawn at rest and during peak exercise. Changes in activity were compared with changes in erythrocyte count. Activity and erythrocyte counts increased during exercise in all 13 subjects. Percent increase in activity correlated with percent increase in erythrocyte count (r . -0.78), but did not correlate with either duration of exercise or maximal heart rate. Twenty minutes after termination of exercise, activity and erythrocyte count had decreased from peak exercise values but remained higher than preexercise values. In nine nonexercised control subjects, samples drawn 20 minutes apart showed no change in activity or in erythrocyte count. We conclude that exercise increases blood activity, primarily because of an increase in erythrocyte count. During radionuclide ventriculography, blood activity must be measured before and after any intervention, particularly exercise, before a change in left ventricular activity can be attributed to a change in left ventricular volume

  9. Measurement of cerebral blood flow the blood sampling method using 99mTc-ECD. Simultaneous scintigram scanning of arterial blood samples and the brain with a gamma camera

    International Nuclear Information System (INIS)

    Hachiya, Takenori; Inugami, Atsushi; Iida, Hidehiro; Mizuta, Yoshihiko; Kawakami, Takeshi; Inoue, Minoru

    1999-01-01

    To measure regional cerebral blood flow (rCBF) by blood sampling using 99m Tc-ECD we devised a method of measuring the radioactive concentration in arterial blood sample with a gamma camera. In this method the head and a blood sample are placed within the same visual field to record the SPECT data of both specimens simultaneously. The results of an evaluation of the counting rate performance, applying the 30 hours decaying method using 99m Tc solution showed that this method is not comparable to the well-type scintillation counter and in clinical cases the active concentration in arterial blood sample remained well within the dynamic range. In addition, examination of the influence of scattered radiation from the brain by the dilution method showed that it was negligible at a distance of more than 7.5 cm between the brain and the arterial blood sample. In the present study we placed a head-shaped phantom next to the sample. The results of the examinations suggested that this method is suitable for clinical application, and because it does not require a well-type scintillation counter, it is expected to find wide application. (author)

  10. Measurement of Androgen and Estrogen Concentrations in Cord Blood: Accuracy, Biological Interpretation and Applications to Understanding Human Behavioural Development

    Directory of Open Access Journals (Sweden)

    Lauren P Hollier

    2014-05-01

    Full Text Available Accurately measuring hormone exposure during prenatal life presents a methodological challenge and there is currently no ‘gold standard’ approach. Ideally, circulating fetal hormone levels would be measured at repeated time points during pregnancy. However, it is not currently possible to obtain fetal blood samples without significant risk to the fetus, and therefore surrogate markers of fetal hormone levels must be utilized. Umbilical cord blood can be readily obtained at birth and largely reflects fetal circulation in late gestation. This review examines the accuracy and biological interpretation of the measurement of androgens and estrogens in cord blood. The use of cord blood hormones to understand and investigate human development is then discussed.

  11. Study of Gamma-Hydroxybutyric Acid (GHB Concentrations in Postmortem Blood and Urine

    Directory of Open Access Journals (Sweden)

    Huda M Hassan

    2015-12-01

    Full Text Available Gamma-hydroxybutyric acid (GHB is present in blood and urine of the general population as an endogenous compound. The published concentrations in postmortem blood ranged from 0-168 mg/L in cases with no previous history of GHB use. Interpretation of GHB results should be carefully considered due to the wide distribution of endogenous concentrations. The objectives of this study are to evaluate and verify the accuracy of a proposed published (50 mg/L cut-off in 120 blood and 64 urine samples in postmortem cases selected randomly, and to identify GHB-related fatalities. GHB was determined by gas chromatography– mass spectrometry (GC–MS after extraction of the blood and urine in the presence of the internal standard GHB-D6.  The GHB concentration in majority of the blood samples (95% was ≤ 50 mg/L, while in 81% it ranged from 10-50 mg/L. In 95% of the urine samples, the GHB concentration ranged from 10-20 mg/L while 82% of the samples had a concentration of 500 mg/L. The proposed published GHB concentration of 50 mg/L may be used as a cut-off to distinguish between natural endogenous concentrations and exogenous use, but this is not sufficient by itself. The detected GHB concentrations, both in vivo and in postmortem samples, require careful interpretation, not only due to its endogenous nature, but also due to the possibility of postmortem production and also due to its rapid metabolism and excretion.In order to distinguish the endogenous GHB concentration from those reflecting abusive GHB levels, defining a specific cut-off value in biological samples is very crucial. Other matrices, such as vitreous humour, femoral blood and hair must also be considered when interpreting postmortem GHB concentrations.

  12. Mass Spectrometry Method to Measure Membrane Proteins in Dried Blood Spots for the Detection of Blood Doping Practices in Sport.

    Science.gov (United States)

    Cox, Holly D; Eichner, Daniel

    2017-09-19

    The dried blood spot (DBS) matrix has significant utility for applications in the field where venous blood collection and timely shipment of labile blood samples is difficult. Unfortunately, protein measurement in DBS is hindered by high abundance proteins and matrix interference that increases with hematocrit. We developed a DBS method to enrich for membrane proteins and remove soluble proteins and matrix interference. Following a wash in a series of buffers, the membrane proteins are digested with trypsin and quantitated by parallel reaction monitoring mass spectrometry methods. The DBS method was applied to the quantification of four cell-specific cluster of differentiation (CD) proteins used to count cells by flow cytometry, band 3 (CD233), CD71, CD45, and CD41. We demonstrate that the DBS method counts low abundance cell types such as immature reticulocytes as well as high abundance cell types such as red blood cells, white blood cells, and platelets. When tested in 82 individuals, counts obtained by the DBS method demonstrated good agreement with flow cytometry and automated hematology analyzers. Importantly, the method allows longitudinal monitoring of CD protein concentration and calculation of interindividual variation which is difficult by other methods. Interindividual variation of band 3 and CD45 was low, 6 and 8%, respectively, while variation of CD41 and CD71 was higher, 18 and 78%, respectively. Longitudinal measurement of CD71 concentration in DBS over an 8-week period demonstrated intraindividual variation 17.1-38.7%. Thus, the method may allow stable longitudinal measurement of blood parameters currently monitored to detect blood doping practices.

  13. Effect of ground cinnamon on postprandial blood glucose concentration in normal-weight and obese adults.

    Science.gov (United States)

    Magistrelli, Ashley; Chezem, Jo Carol

    2012-11-01

    In healthy normal-weight adults, cinnamon reduces blood glucose concentration and enhances insulin sensitivity. Insulin resistance, resulting in increased fasting and postprandial blood glucose and insulin levels, is commonly observed in obese individuals. The objective of the study was to compare declines in postprandial glycemic response in normal-weight and obese subjects with ingestion of 6 g ground cinnamon. In a crossover study, subjects consumed 50 g available carbohydrate in instant farina cereal, served plain or with 6 g ground cinnamon. Blood glucose concentration, the main outcome measure, was assessed at minutes 0, 15, 30, 45, 60, 90, and 120. Repeated-measures analysis of variance evaluated the effects of body mass index (BMI) group, dietary condition, and time on blood glucose. Paired t-test assessed blood glucose at individual time points and glucose area under the curve (AUC) between dietary conditions. Thirty subjects between the ages of 18 and 30 years, 15 with BMIs between 18.5 and 24.9 and 15 with BMIs of 30.0 or more, completed the study. There was no significant difference in blood glucose between the two BMI groups at any time point. However, in a combined analysis of all subjects, the addition of cinnamon to the cereal significantly reduced 120-minute glucose AUC (P=0.008) and blood glucose at 15 (P=0.001), 30 (Pblood glucose was significantly higher with cinnamon consumption (Pglucose response in normal weight and obese adults. Copyright © 2012 Academy of Nutrition and Dietetics. Published by Elsevier Inc. All rights reserved.

  14. Cancer and Blood Concentrations of the Co-mutagen Harmane in Essential Tremor

    Science.gov (United States)

    Louis, Elan D.; Pellegrino, Kathryn M.; Factor-Litvak, Pam; Rios, Eileen; Jiang, Wendy; Henchcliffe, Claire; Zheng, Wei

    2008-01-01

    Background Blood concentrations of harmane, a tremor-producing neurotoxin, are elevated in essential tremor (ET). Harmane is also a co-mutagen. Objective To compare the prevalence of cancer in ET cases vs. controls, and determine whether blood harmane concentrations are elevated among ET cases with cancer. Methods Case-control design. Results 66/267 (24.7%) ET cases vs. 55/331 (16.6%) controls had cancer (adjusted OR 1.52, 95% CI 1.01 – 2.30, p = 0.04). Among specific cancer types, colon cancer was more prevalent in ET cases than controls (2.6% vs. 0.6%, p = 0.04). Log blood harmane concentration was higher in ET cases vs. controls (p = 0.02) and in participants with vs. without cancer (p = 0.02). Log blood harmane concentration was highest in ET cases with cancer when compared with other groups (p = 0.009). Discussion These links between cancer and ET and between high blood harmane and cancer in ET deserve further study. PMID:18709680

  15. Concentrations of metals in blood and feathers of nestling ospreys (Pandion haliaetus) in Chesapeake and Delaware Bays

    Science.gov (United States)

    Rattner, B.A.; Golden, N.H.; Toschik, P.C.; McGowan, P.C.; Custer, T.W.

    2008-01-01

    In 2000, 2001, and 2002, blood and feather samples were collected from 40-45-day-old nestling ospreys (Pandion haliaetus) from Chesapeake Bay and Delaware Bay and River. Concentrations of 18 metals, metalloids, and other elements were determined in these samples by inductively coupled plasma-mass spectroscopy, and Hg concentrations were measured by cold vapor atomic absorption spectroscopy. When compared to concurrent reference areas (South, West, and Rhode Rivers), mean As and Hg concentrations in blood were greater (p nestlings from the highly industrialized Elizabeth River compared to the rural reference area. When compared to the concurrent reference area, mean Al, Ba, Hg, Mn, and Pb concentrations in feathers were substantially greater (p nestlings from northern Delaware Bay and River had greater concentrations (p nestling feathers from Delaware were frequently greater than in the Chesapeake. The present findings and those of related reproductive studies suggest that concentrations of several heavy metals (e.g., Cd, Hg, Pb) in nestling blood and feathers from Chesapeake and Delaware Bays were below toxicity thresholds and do not seem to be affecting chick survival during the nestling period.

  16. Performance IQ in children is associated with blood cadmium concentration in early pregnancy.

    Science.gov (United States)

    Jeong, Kyoung Sook; Park, Hyewon; Ha, Eunhee; Hong, Yun-Chul; Ha, Mina; Park, Hyesook; Kim, Bung-Nyun; Lee, Bo-Eun; Lee, Soo-Jeong; Lee, Kyung Yeon; Kim, Ja Hyeong; Kim, Yangho

    2015-04-01

    To investigate whether performance IQ in children is associated with maternal blood cadmium concentration in early pregnancy. The present study is a component of the Mothers' and Children's Environmental Health (MOCEH) study, a multi-center birth cohort project in Korea that began in 2006. The study cohort consisted of 119 children whose mothers underwent testing of blood cadmium during early pregnancy. All children were evaluated using the Korean version of the Wechsler Preschool and Primary Scale of Intelligence, revised edition (WPPSI-R), at 60 months of age. Multivariate linear regression analysis was performed to analyze the correlation between IQ in children and maternal blood cadmium concentration in early pregnancy, after adjustment for covariates. Maternal blood cadmium concentration during early pregnancy was inversely associated with performance IQ, after adjustment for covariates such as sex, educational levels of both parents, family income, and maternal BMI. Maternal blood cadmium concentration, however, was not associated with cognitive IQ. Performance IQ in children is associated with maternal blood cadmium concentration in early pregnancy. Copyright © 2014 Elsevier GmbH. All rights reserved.

  17. In vivo Raman measurement of levofloxacin lactate in blood using a nanoparticle-coated optical fiber probe

    Science.gov (United States)

    Liu, Shupeng; Rong, Ming; Zhang, Heng; Chen, Na; Pang, Fufei; Chen, Zhenyi; Wang, Tingyun; Yan, Jianshe

    2016-01-01

    Monitoring drug concentrations in vivo is very useful for adjusting a drug dosage during treatment and for drug research. Specifically, cutting-edge “on-line” drug research relies on knowing how drugs are metabolized or how they interact with the blood in real-time. Thus, this study explored performing in vivo Raman measurements of the model drug levofloxacin lactate in the blood using a nanoparticle-coated optical fiber probe (optical fiber nano-probe). The results show that we were able to measure real-time changes in the blood concentration of levofloxacin lactate, suggesting that this technique could be helpful for performing drug analyses and drug monitoring in a clinical setting without repeatedly withdrawing blood from patients. PMID:27231590

  18. Carbon monoxide and COHb concentration in blood in various circumstances

    Energy Technology Data Exchange (ETDEWEB)

    Modic, J. [Faculty of Mechanical Engineering, University of Ljubljana, Ljubljana (Slovenia)

    2003-07-01

    On the basis of known medical experiments we find out the correlation between the concentration of carbon monoxide (CO) in inhaling air and the concentration of carboxihemoglobyne (COHb) in human blood. All internal combustion engines produce exhaust gases containing noxious compounds: carbon monoxide, nitrogen oxides (NO{sub x}), carbon oxides (CxHy) and smoke. In a living room is important the smoke of cigarettes, smoke of furnaces, improper ventilation. In tunnel is most dangerous the carbon monoxide if it exceeds an allowable level. In human blood the carbon monoxide causes increasing the concentration of carboxihemoglobyne and in this case the hypoxia of web. With help of mathematical model the concentrations of some dangerous substances at the end of tunnel were calculated. For this case a differential equation also was developed and it shows the correlation between concentration of carbon monoxide in the air and concentration of carboxihemoglobyne in the blood. The constructed mathematical model shows circumstances in the tunnel (velocity of air moving as effect of induction, concentration of noxious substances and criterial number). Also a corresponding computer program was developed, which makes possible a quick and simple calculation. All the results are proved by experiments. Finally the differential equation was done, which shows a temporal connection between both parameters as a function of tunnel characteristics. (author)

  19. Measurements of vitamin B12 in human blood serum using resonance Raman spectroscopy

    Science.gov (United States)

    Tsiminis, G.; Schartner, E. P.; Brooks, J. L.; Hutchinson, M. R.

    2016-12-01

    Vitamin B12 (cobalamin and its derivatives) deficiency has been identified as a potential modifiable risk factor for dementia and Alzheimer's disease. Chronic deficiency of vitamin B12 has been significantly associated with an increased risk of cognitive decline. An effective and efficient method for measuring vitamin B12 concentration in human blood would enable ongoing tracking and assessment of this potential modifiable risk factor. In this work we present an optical sensor based on resonance Raman spectroscopy for rapid measurements of vitamin B12 in human blood serum. The measurement takes less than a minute and requires minimum preparation (centrifuging) of the collected blood samples.

  20. Reference Brain/Blood Concentrations of Citalopram, Duloxetine, Mirtazapine and Sertraline

    DEFF Research Database (Denmark)

    Nedahl, Michael; Johansen, Sys Stybe; Linnet, Kristian

    2018-01-01

    Postmortem blood samples may not accurately reflect antemortem drug concentrations, as the levels of some drugs increase due to postmortem redistribution (PMR). The brain has been suggested as an alternative sampling site. The anatomically secluded site of the brain limits redistribution and prol.......85), whereas the median citalopram/N-desmethylcitalopram ratio was higher in brain (9.1) than blood (4.1). The results of this study may serve as reference concentrations in brain for forensic cases....

  1. Blood serum concentrations of kynurenic acid in patients diagnosed with recurrent depressive disorder, depression in bipolar disorder, and schizoaffective disorder treated with electroconvulsive therapy.

    Science.gov (United States)

    Olajossy, Marcin; Olajossy, Bartosz; Wnuk, Sebastian; Potembska, Emilia; Urbańska, Ewa

    2017-06-18

    The aim of the present study was to compare blood serum kynurenic acid (KYNA) concentrations measured before ECT and after 1, 6 and 12 electroconvulsive treatment (ECT) sessions in patients with diagnoses of recurrent depressive disorder (RDD), depression in bipolar disorder (DBD) and schizoaffective disorder (SAD). The study group comprised of 50 patients with ICD-10 diagnoses of RDD, DBD and SAD. Blood serum KYNA concentrations were determined and clinical assessment was performed using the MADRS and the GAF scale. Significant differences were found in blood serum KYNA levels between RDD, DBD and SAD patients treated with electroconvulsive therapy and healthy controls: 1) KYNA concentrations in DBD patients measured before ECT and after 12 ECT sessions were significantly lower than in the control group; 2) KYNA concentrations in the serum of RDD patients measured before ECT and after one and 12 ECT sessions were significantly lower than in the control group, while those measured after 6 ECT session did not differ significantly from KYNA concentrations in healthy controls; 3) higher pre-treatment blood serum concentrations of KYNA in DBD patients correlated with a higher number of illness phases and poorer general functioning before treatment; 4) significant relationships were found between higher blood serum concentrations of KYNA in RDD patients after 1 ECT session and male gender, and between higher KYNA concentrations after 6 ECT sessions and increased depression and poorer functioning before treatment in those patients. Results show that KYNA concentrations in all diagnostic groups were lower before ECT (not statistically significant for the SAD group) and that there were no significant changes in those concentrations (compared with the baseline) during ECT.

  2. Blood Contamination in Saliva: Impact on the Measurement of Salivary Oxidative Stress Markers

    Directory of Open Access Journals (Sweden)

    Natália Kamodyová

    2015-01-01

    Full Text Available Salivary oxidative stress markers represent a promising tool for monitoring of oral diseases. Saliva can often be contaminated by blood, especially in patients with periodontitis. The aim of our study was to examine the impact of blood contamination on the measurement of salivary oxidative stress markers. Saliva samples were collected from 10 healthy volunteers and were artificially contaminated with blood (final concentration 0.001–10%. Next, saliva was collected from 12 gingivitis and 10 control patients before and after dental hygiene treatment. Markers of oxidative stress were measured in all collected saliva samples. Advanced oxidation protein products (AOPP, advanced glycation end products (AGEs, and antioxidant status were changed in 1% blood-contaminated saliva. Salivary AOPP were increased in control and patients after dental treatment (by 45.7% and 34.1%, p<0.01. Salivary AGEs were decreased in patients after microinjury (by 69.3%, p<0.001. Salivary antioxidant status markers were decreased in both control and patients after dental treatment (p<0.05 and p<0.01. One % blood contamination biased concentrations of salivary oxidative stress markers. Saliva samples with 1% blood contamination are visibly discolored and can be excluded from analyses without any specific biochemic detection of blood constituents. Salivary markers of oxidative stress were significantly altered in blood-contaminated saliva in control and patients with gingivitis after dental hygiene treatment.

  3. Storage time of platelet concentrates and risk of a positive blood culture

    DEFF Research Database (Denmark)

    Kreuger, Aukje L; Rostgaard, Klaus; Middelburg, Rutger A

    2018-01-01

    BACKGROUND: Concern of transfusion-transmitted bacterial infections has been the major hurdle to extend shelf life of platelet (PLT) concentrates. We aimed to investigate the association between storage time and risk of positive blood cultures at different times after transfusion. STUDY DESIGN...... AND METHODS: We performed a nationwide cohort study among PLT transfusion recipients in Denmark between 2010 and 2012, as recorded in the Scandinavian Donations and Transfusions (SCANDAT2) database. Linking with a nationwide database on blood cultures (MiBa), we compared the incidence of a positive blood......) of a positive blood culture the day after transfusion of at least one old PLT concentrate was 0.77 (95% confidence interval [CI], 0.54-1.09) compared to transfusion of fresh PLT concentrates. The incidence rate of a positive blood culture was lower the day after receiving one old compared to one fresh PLT...

  4. BLOOD LEAD CONCENTRATION AND DELAYED PUBERTY IN GIRLS

    Science.gov (United States)

    Background Environmental lead exposure has been linked to alterations in growth and endocrine function. It is not known whether such exposure affects pubertal development.Methods We analyzed the relations between blood lead concentration and pubertal...

  5. Whole-Blood Taurine Concentrations in Cats With Intestinal Disease.

    Science.gov (United States)

    Kathrani, A; Fascetti, A J; Larsen, J A; Maunder, C; Hall, E J

    2017-07-01

    Increased delivery of taurine-conjugated bile acids to the distal bowel can lead to dysbiosis resulting in colitis in mouse models of inflammatory bowel disease. A similar situation also could occur in cats with intestinal disease and might therefore result in decreased whole-body taurine concentration. To determine whether whole-blood taurine concentrations are decreased at the time of diagnosis in cats with intestinal disease and to correlate concentrations with clinical and laboratory variables. Twenty-one cats with chronic inflammatory enteropathy and 7 cats with intestinal neoplasia from the University of Bristol. Cats that had undergone a thorough investigation consisting of a CBC, serum biochemistry, serum cobalamin and folate concentrations, transabdominal ultrasound examination and histopathology of intestinal biopsy specimens, as well as additional testing if indicated, were included. Whole-blood from these cats collected at the time of histologic diagnosis and stored in ethylenediaminetetraacetic acid was retrospectively analyzed for taurine with an automated high-performance liquid chromatography amino acid analyzer. Although whole-blood taurine concentrations remained within the reference range, those cats with predominantly large intestinal clinical signs had significantly lower concentrations than did cats with small intestinal and mixed bowel clinical signs (P = 0.033) and this difference also was significant when assessed only in cats with chronic inflammatory enteropathy (P = 0.019). Additional studies are needed to determine whether large intestinal signs in cats with chronic inflammatory enteropathy are caused by alterations in the microbiota arising as a consequence of increased delivery of taurine-conjugated bile acids. Copyright © 2017 The Authors. Journal of Veterinary Internal Medicine published by Wiley Periodicals, Inc. on behalf of the American College of Veterinary Internal Medicine.

  6. Blood cadmium concentration and lipid profile in Korean adults

    International Nuclear Information System (INIS)

    Kim, Kisok

    2012-01-01

    Although animal experiments have shown that cadmium exposure induces alterations in lipid profiles, no epidemiological study of this relationship has been performed. The objective of this study was to evaluate the association between blood cadmium concentration and blood lipid levels in Korean adults. A cross-sectional study comprising participants (n=3903) aged 20 years or older from the 2005, 2008, and 2009 Korea National Health and Nutrition Examination Surveys was conducted. Demographic characteristics and dietary intake were obtained from the participants by questionnaire, and cadmium and lipid levels were determined by analysis of blood samples. After adjusting for demographic and dietary factors, blood concentration of cadmium was positively associated with the risk of low high-density lipoprotein cholesterol (HDL-C) in a dose-dependent manner (p for trend <0.001). In addition, the odds ratios (ORs) of a high triglyceride to HDL-C ratio was significantly increased in the high blood cadmium groups [OR=1.36; 95% confidence interval (CI), 1.03–1.79 for fourth quintile and OR=1.41; 95% CI, 1.07–1.86 for fifth quintile] compared with the lowest quintile group. However, high blood cadmium was not associated with a risk of high total cholesterol, high low-density lipoprotein cholesterol, or high triglycerides. These data suggest that an increased cadmium body burden increases the risk of dyslipidemia, mainly due to the increased risk of low HDL-C and the high ratio of triglycerides to HDL-C.

  7. Blood cadmium concentration and lipid profile in Korean adults

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Kisok [Department of Public Health, Keimyung University, 1000 Shindang-dong, Daegu 704-701 (Korea, Republic of)

    2012-01-15

    Although animal experiments have shown that cadmium exposure induces alterations in lipid profiles, no epidemiological study of this relationship has been performed. The objective of this study was to evaluate the association between blood cadmium concentration and blood lipid levels in Korean adults. A cross-sectional study comprising participants (n=3903) aged 20 years or older from the 2005, 2008, and 2009 Korea National Health and Nutrition Examination Surveys was conducted. Demographic characteristics and dietary intake were obtained from the participants by questionnaire, and cadmium and lipid levels were determined by analysis of blood samples. After adjusting for demographic and dietary factors, blood concentration of cadmium was positively associated with the risk of low high-density lipoprotein cholesterol (HDL-C) in a dose-dependent manner (p for trend <0.001). In addition, the odds ratios (ORs) of a high triglyceride to HDL-C ratio was significantly increased in the high blood cadmium groups [OR=1.36; 95% confidence interval (CI), 1.03-1.79 for fourth quintile and OR=1.41; 95% CI, 1.07-1.86 for fifth quintile] compared with the lowest quintile group. However, high blood cadmium was not associated with a risk of high total cholesterol, high low-density lipoprotein cholesterol, or high triglycerides. These data suggest that an increased cadmium body burden increases the risk of dyslipidemia, mainly due to the increased risk of low HDL-C and the high ratio of triglycerides to HDL-C.

  8. PET measurement of FK506 concentration in a monkey model of stroke

    International Nuclear Information System (INIS)

    Murakami, Yoshihiro; Takamatsu, Hiroyuki; Noda, Akihiro; Osoda, Kazuhiko; Nishimura, Shintaro

    2007-01-01

    Introduction: The immunosuppressive agent FK506 (tacrolimus) has neuroprotective properties in an experimental model of cerebral ischemia. To improve the accuracy of clinical studies in acute stroke, a clinical dose setting should be based on the brain concentration, but not on the blood concentration of agents in humans. We have already established a measurement method using PET for FK506 concentration in the normal monkey brain, which could be applicable for human study; however, under ischemic conditions, in this study, we aimed to examine the brain concentration of FK506 in a monkey model of stroke. Methods: Studies were performed on six male cynomolgus monkeys (Macaca fascicularis) and a middle cerebral artery (MCA) occlusion model was used. Regional cerebral blood flow (rCBF) was measured by an intravenous injection of [ 15 O]H 2 O 165 min after MCA occlusion. FK506 (0.1 mg/kg) containing [ 11 C]FK506 was intravenously injected into the monkeys 180 min after MCA occlusion, and dynamic PET images were acquired for 30 min after administration. FK506 concentrations in the brain were calculated in moles per liter (M) units using the specific activity of injected FK506. Results: MCA occlusion produced ischemia, confirmed by rCBF measurement before the administration of [ 11 C]FK506. Fifteen minutes after FK506 (0.1 mg/kg) administration, the concentrations in the contralateral and ipsilateral cortex were 22.4±6.4 and 19.7±4.0 ng/g, respectively. Conclusion: We successfully measured the brain concentration of FK506 in a monkey model of stroke. The difference between the contralateral and ipsilateral concentrations of FK506 was not significant. This characteristic that FK506 readily penetrates ischemic tissue as well as normal tissue might explain the neuroprotective effect of FK506 in the ischemic brain and is suitable for the treatment of stroke patients

  9. Dietary thiamin and riboflavin intake and blood thiamin and riboflavin concentrations in college swimmers undergoing intensive training.

    Science.gov (United States)

    Sato, Akiko; Shimoyama, Yoshimitsu; Ishikawa, Tomoji; Murayama, Nobuko

    2011-06-01

    The purpose of this study was to examine the effect of high-intensity physical activity during training on the biochemical status of thiamin and riboflavin in athletes. Thiamin and riboflavin concentrations in whole blood of a group of 19 athletes (6 men and 13 women) were measured during a low-intensity preparatory period and compared with measurements taken during a high-intensity training period. Additional variables measured included anthropometric characteristics, estimated energy expenditure during swim training, distance covered, resting energy expenditure obtained by indirect calorimetry, estimated energy requirement per day, and dietary intake of energy, thiamin, and riboflavin estimated from 3-day food records. For both male and female subjects, no major changes were observed in anthropometric characteristics or dietary intake, but energy expenditure during swim training per day significantly increased in the intensive-training period (496 ± 0 kcal in the preparation period compared with 995 ± 96 kcal in the intensive-training period for male subjects [p riboflavin was unchanged. These results suggest that intense training affects thiamin concentration, but not riboflavin concentration, in the whole blood of college swimmers.

  10. Measurement of hydroxylated PCB metabolites for Slovakia maternal blood serums

    Energy Technology Data Exchange (ETDEWEB)

    Park, J.S.; Athanasiadou, M; Bergman, A. [Stockholm Univ., Stockholm (Sweden); Charles, J.; Zhao, G.; Hertz-Picciotto, I. [California Univ., Sacramento, CA (United States); Petrik, J.; Kocan, A; Trnovec, T. [Bratislava Inst. of Preventive and Clinical Medicine, Bratislava (Slovakia)

    2005-07-01

    Although it is known that polychlorinated biphenyls (PCBs) have adverse impacts on human health, it is not clear if human health impacts are caused by the PCBs or their related hydroxylated (OH) PCB metabolite compounds. This study measured OH-PCB metabolites in the maternal blood serum specimens from the Svidnik and Michalovce areas in eastern Slovakia where PCBs were intensively produced and inadequately disposed. The aim of the study was to characterize and quantify levels of specific OH-PCB metabolites in Slovakian maternal serums exposed to high environmental PCB levels. All specimens were analyzed for PCBs, and a subset of the samples was analyzed for OH-PCB metabolites. The Wallenburg blood extraction method was adopted to separate the OH-PCBs from the blood serums. Final eluates and calibration standards were spiked with PCB209 as an injection standard before gas chromatography (GC) analysis. OH-PCBs in the samples range from 75{+-}9 per cent to 101{+-}11 per cent. Median concentrations of OH-PCB metabolites of Michalovce samples were approximately twice as high as for the Svidnik samples. Concentrations of OH-PCBs of Michalovce blood samples were comparable to samples obtained from northern Canadian female Inuit and Faroe Island females, and were considered to be among the highest OH-PCB concentrations obtained in human blood. It was concluded that further research is needed to understand the placental transfer of OH-PCBs to the fetus, as well as epidemiological approaches to determine the relationship between the exposure of OH-PCB metabolites and child development. 12 refs., 2 figs.

  11. Blood lead exposure concentrations in mottled ducks (Anas fulvigula) on the upper Texas coast

    Science.gov (United States)

    McDowell, Stephen K.; Conway, Warren C.; Haukos, David A.; Moon, Jena A.; Comer, Christopher E.; Hung, I-Kuai

    2015-01-01

    The mottled duck (Anas fulvigula) is a non-migratory waterfowl species dependent upon coastal marsh systems, including those on the Texas Chenier Plain National Wildlife Refuge (NWR) Complex, and considered a regional indicator species of marsh habitat quality. Research from the early 1970s, 1990s, and early-2000s indicated that mottled ducks continued to exhibit elevated wing-bone lead (Pb) concentrations, decades after implementation of non-toxic shot regulations. However, wing-bone concentrations reflect lifetime accumulation of Pb, whereas blood Pb concentrations reflect more recent exposure. To identify current potentially relevant temporal windows of Pb exposure, we collected 260 blood samples from mottled ducks during summer (n=124) and winter (n=136) from 2010–2012 on the Texas Chenier Plain NWR Complex. We quantified baseline blood Pb concentrations for all ages of mottled ducks, and hypothesized that blood lead concentrations would remain elevated above background levels (200 µg L–1) despite the 1983 and 1991 lead shot bans. Blood Pb concentrations ranged from below detection limits to >12,000 µg L–1, where >200 µg L–1 was associated with exposure levels above background concentrations. Male mottled ducks had the greatest blood Pb concentrations (30 times greater than females) with concentrations greater during winter than summer. Likewise, the proportion of exposed (>200 µg L–1) females increased from 14%–47% from summer to winter, respectively. Regardless of sex, adult mottled duck blood Pb concentrations were five times greater than juveniles, particularly during winter. We identified five plausible models that influenced blood Pb levels where year, site, and interactions among age*sex*season and between age*season were included in the top-ranked models. Frequency of exposure was greatest during winter, increasing from 12% in summer to 55% in winter, indicating that a temporal exposure window to environmental Pb exists between nesting

  12. Concentrations of isoflavones and their metabolites in the blood of pregnant and non-pregnant heifers fed soy bean.

    Science.gov (United States)

    Woclawek-Potocka, Izabela; Piskula, Mariusz Krzysztof; Bah, Mamadou; Siemieniuch, Marta Jolanta; Korzekwa, Anna; Brzezicka, Edyta; Skarzynski, Dariusz Jan

    2008-10-01

    The present study compared the changes in isoflavones (daidzein and genistein) and their metabolite (equol and para-ethyl-phenol) concentrations in the blood plasma of cyclic and pregnant heifers after feeding with soy bean. Twelve healthy heifers were divided into three groups: cyclic heifers (days 8-12 of the estrous cycle; control group; n=4), an early pregnancy group (2 months pregnant; n=4) and a late pregnancy group (8 months pregnant; n=4). All heifers were fed a single dose of 2.5 kg of soy bean and then blood samples were taken from the jugular vein for 8 h at predetermined intervals. The concentrations of soy bean-derived isoflavones and their active metabolites were measured in the blood plasma on an HPLC system. In the blood plasma of the early- and late-pregnant heifers, we found lower concentrations and time-dependent decreases in daidzein and genistein in comparison to cyclic heifers (P0.05). In conclusion, physiological status (cyclicity or pregnancy) of the females influenced the concentrations of isoflavone metabolites in the blood plasma of the heifers. The stage of pregnancy affects isoflavone absorption, biotransformation and metabolism differently and results in higher concentrations of active metabolites of isoflavones during early pregnancy in comparison to their lower concentrations during late pregnancy. Therefore, we surmise that cows are more sensitive to active isoflavone metabolite actions during early pregnancy than cyclic heifers and heifers in late pregnancy.

  13. Single Sodium Pyruvate Ingestion Modifies Blood Acid-Base Status and Post-Exercise Lactate Concentration in Humans

    Directory of Open Access Journals (Sweden)

    Robert A. Olek

    2014-05-01

    Full Text Available This study examined the effect of a single sodium pyruvate ingestion on a blood acid-base status and exercise metabolism markers. Nine active, but non-specifically trained, male subjects participated in the double-blind, placebo-controlled, crossover study. One hour prior to the exercise, subjects ingested either 0.1 g·kg−1 of body mass of a sodium pyruvate or placebo. The capillary blood samples were obtained at rest, 60 min after ingestion, and then three and 15 min after completing the workout protocol to analyze acid-base status and lactate, pyruvate, alanine, glucose concentrations. The pulmonary gas exchange, minute ventilation and the heart rate were measured during the exercise at a constant power output, corresponding to ~90% O2max. The blood pH, bicarbonate and the base excess were significantly higher after sodium pyruvate ingestion than in the placebo trial. The blood lactate concentration was not different after the ingestion, but the post-exercise was significantly higher in the pyruvate trial (12.9 ± 0.9 mM than in the placebo trial (10.6 ± 0.3 mM, p < 0.05 and remained elevated (nonsignificant after 15 min of recovery. The blood pyruvate, alanine and glucose concentrations, as well as the overall pulmonary gas exchange during the exercise were not affected by the pyruvate ingestion. In conclusion, the sodium pyruvate ingestion one hour before workout modified the blood acid-base status and the lactate production during the exercise.

  14. Alcohol intoxication at Swedish football matches: A study using biological sampling to assess blood alcohol concentration levels among spectators.

    Directory of Open Access Journals (Sweden)

    Natalie Durbeej

    Full Text Available Alcohol use and alcohol-related problems, including accidents, vandalism and violence, at sporting events are of increased concern in Sweden and other countries. The relationship between alcohol use and violence has been established and can be explained by the level of intoxication. Given the occurrence of alcohol use and alcohol-related problems at sporting events, research has assessed intoxication levels measured through biological sampling among spectators. This cross-sectional study aimed to assess the level of alcohol intoxication among spectators at football matches in the Swedish Premier Football League. Spectators were randomly selected and invited to participate in the study. Alcohol intoxication was measured with a breath analyser for Blood Alcohol Concentration levels, and data on gender, age, and recent alcohol use were gathered through a face-to-face interview. Blood Alcohol Concentration samples from 4420 spectators were collected. Almost half (46.8% had a positive Blood Alcohol Concentration level, with a mean value of 0.063%, while 8.9% had a Blood Alcohol Concentration level ≥ 0.1%, with a mean value of 0.135%. Factors that predicted a higher Blood Alcohol Concentration level included male gender (p = 0.005, lower age (p < 0.001, attending a local derby (p < 0.001, alcohol use prior to having entered the arena (p < 0.001, attending a weekend match (p < 0.001, and being a spectator at supporter sections (p < 0.001. About half of all spectators at football matches in the Swedish Premier Football League drink alcohol in conjunction with the match. Approximately one tenth have a high level of alcohol intoxication.

  15. Plasma concentrations of endothelial vasoactive substances in clinically healthy subjects. associations with urinary albumin excretion and ambulatory blood pressure

    DEFF Research Database (Denmark)

    Clausen, P; Jensen, J S; Jensent, G

    2000-01-01

    controls with normoalbuminuria. Plasma concentration of ET-1 was measured using an ELISA method and plasma concentration of nitrate/nitrite using a photometric method. Twenty-four-hour blood pressure was measured using a portable recorder (TM-2421). No significant differences in the concentrations...... of nitrate/nitrite and ET-1 were found between the groups, e.g. 21 (10-105) vs. 18 (11 -152) (p=0.33) and 0.98 (0.58 1.95) vs. 1.10 (0.54 -1.50) (p = 0.27), respectively. However, plasma nitrate/nitrite was significantly positively correlated to systolic and diastolic blood pressure in subjects...... in clinically healthy subjects. However, nitrate/nitrite is positively correlated to BP only in subjects with normoalbuminuria, and ET-1 is positively correlated to BP only in subjects with elevated UAE....

  16. The effect of increased centrifugation temperature on the quality of red-blood-cell concentrates of automated whole blood processing.

    Science.gov (United States)

    Weinigel, C; Rummler, S; Barz, D

    2013-10-01

    There are manual and automated methods to separate whole blood (WB) available. The Atreus whole blood processing system is an automated method, which combines centrifugation and expression of components into a single device. A major difference to conventional methods is that centrifugation temperature is not controlled at 22°C. The aim of this study was to examine the influence of increased centrifugation temperatures on the quality of red-blood-cell concentrates (RCC) after active cooling of WB prior to processing. A total of 28 WB were processed: 16 at centrifugation temperatures of up to 28°C (1st protocol) and 12 at 34°C (2nd protocol). RCC quality parameters were tested weekly for 42 days. Red-blood-cell concentrates (RCC) quality complied with the European and German guidelines. Haemolysis was not significantly different throughout storage. Significant statistical differences were detected between both protocols in potassium concentration at the end of storage and in ATP levels at the day of processing. Centrifugation temperatures of up to 34°C are well tolerated by the red blood cells with minimal interference with the RCC quality parameters. © 2013 International Society of Blood Transfusion.

  17. Blood Pressure Measurement: Clinic, Home, Ambulatory, and Beyond

    Science.gov (United States)

    Drawz, Paul E.; Abdalla, Mohamed; Rahman, Mahboob

    2014-01-01

    Blood pressure has traditionally been measured in the clinic setting using the auscultory method and a mercury sphygmomanometer. Technological advances have led to improvements in measuring clinic blood pressure and allowed for measuring blood pressures outside the clinic. This review outlines various methods for evaluating blood pressure and the clinical utility of each type of measurement. Home blood pressures and 24 hour ambulatory blood pressures have improved our ability to evaluate risk for target organ damage and hypertension related morbidity and mortality. Measuring home blood pressures may lead to more active participation in health care by patients and has the potential to improve blood pressure control. Ambulatory blood pressure monitoring enables the measuring nighttime blood pressures and diurnal changes, which may be the most accurate predictors of risk associated with elevated blood pressure. Additionally, reducing nighttime blood pressure is feasible and may be an important component of effective antihypertensive therapy. Finally, estimating central aortic pressures and pulse wave velocity are two of the newer methods for assessing blood pressure and hypertension related target organ damage. PMID:22521624

  18. Reference Ranges of Serum Blood Urea Nitrogen, Creatinine Concentration and Ultrasonographic Measurement of the Kidneys in Term Healthy Newborns in the Neonatal Period

    Directory of Open Access Journals (Sweden)

    Şebnem Kader

    2017-12-01

    Full Text Available Objective: Acute kidney injury is an important problem in neonates. We conducted a cross-sectional prospective study to determine normal serum blood urea nitrogen, creatinine reference ranges and ranges of ultrasonographic measurement of kidneys in healthy term newborns. Study Design: Blood samples were collected from total 357 healthy newborns at birth (n=45, 1st (n=30, 3rd (n=61, 7th (n=34, 10th (n=132, 14th (n=36, and 28th (n=19 days of life. Renal ultrasonographic was performed by the same two radiologists on 81 newborns aged 10 days. Results: Serum blood urea nitrogen and creatinine concentrations have reached to the highest level at the first day of life and have returned to cord level at the third day of life. There were gradually decrease in serum blood urea nitrogen and creatinine levels after the first day of life. There were significant difference in both right and left renal length, width, and volumes in terms of gender and these parameters were statistically higher in boys than girls (p<0.05. Birth weight of the boys (3548±539g was statistically higher than girls (3307±405 g (p=0.028. There was a positive correlation between birth weight and right (r=0.38, p=0.000 and left kidney volumes (r=0.44, p=0.000. Conclusion: Our findings showed that measured blood urea nitrogen and creatinine levels changed in accordance with postnatal days and there was a positive correlation between kidney volume and birth weight of newborns. We concluded that these findings are important for evaluation of acute kidney injury and for screening of for urinary tract anomalies in neonates

  19. Blood lead concentrations in Alaskan tundra swans: linking breeding and wintering areas with satellite telemetry.

    Science.gov (United States)

    Ely, Craig R; Franson, J Christian

    2014-04-01

    Tundra swans (Cygnus columbianus) like many waterfowl species are susceptible to lead (Pb) poisoning, and Pb-induced mortality has been reported from many areas of their wintering range. Little is known however about Pb levels throughout the annual cycle of tundra swans, especially during summer when birds are on remote northern breeding areas where they are less likely to be exposed to anthropogenic sources of Pb. Our objective was to document summer Pb levels in tundra swans throughout their breeding range in Alaska to determine if there were population-specific differences in blood Pb concentrations that might pose a threat to swans and to humans that may consume them. We measured blood Pb concentrations in tundra swans at five locations in Alaska, representing birds that winter in both the Pacific Flyway and Atlantic Flyway. We also marked swans at each location with satellite transmitters and coded neck bands, to identify staging and wintering sites and determine if winter site use correlated with summer Pb concentrations. Blood Pb levels were generally low (<0.2 μg/ml) in swans across all breeding areas. Pb levels were lower in cygnets than adults, suggesting that swans were likely exposed to Pb on wintering areas or on return migration to Alaska, rather than on the summer breeding grounds. Blood Pb levels varied significantly across the five breeding areas, with highest concentrations in birds on the North Slope of Alaska (wintering in the Atlantic Flyway), and lowest in birds from the lower Alaska Peninsula that rarely migrate south for winter.

  20. The effect of interior lead hazard controls on children's blood lead concentrations: a systematic evaluation.

    Science.gov (United States)

    Haynes, Erin; Lanphear, Bruce P; Tohn, Ellen; Farr, Nick; Rhoads, George G

    2002-01-01

    Dust control is often recommended to prevent children's exposure to residential lead hazards, but the effect of these controls on children's blood lead concentrations is uncertain. We conducted a systematic review of randomized, controlled trials of low-cost, lead hazard control interventions to determine the effect of lead hazard control on children's blood lead concentration. Four trials met the inclusion criteria. We examined mean blood lead concentration and elevated blood lead concentrations (> or = 10 microg/dL, > or = 15 microg/dL, and > or = 20 microg/dL) and found no significant differences in mean change in blood lead concentration for children by random group assignment (children assigned to the intervention group compared with those assigned to the control group). We found no significant difference between the intervention and control groups in the percentage of children with blood lead > or = 10 microg/dL, 29% versus 32% [odds ratio (OR), 0.85; 95% confidence interval (CI), 0.56-1.3], but there was a significant difference in the percentage of children with blood lead > or = 15 microg/dL between the intervention and control groups, 6% versus 14% (OR, 0.40; 95% CI, 0.21-0.80) and in the percentage of children with blood lead > or = 20 microg/dL between the intervention and control groups, 2% versus 6% (OR, 0.29; 95% CI, 0.10-0.85). We conclude that although low-cost, interior lead hazard control was associated with 50% or greater reduction in the proportion of children who had blood lead concentrations exceeding 15 microg/dL and > or = 20 microg/dL, there was no substantial effect on mean blood lead concentration.

  1. Measuring high-sensitivity cardiac troponin T blood concentration in population surveys.

    OpenAIRE

    Lazzarino, AI; Mindell, JS

    2017-01-01

    Introduction The blood test for high-sensitivity cardiac troponin T (HS-CTnT) has been proposed as a marker of cardiovascular risk in the general population, as it is associated with subsequent incidence of cardiovascular events and mortality. We aimed at evaluating the feasibility of HS-CTnT testing within large nationally-representative population surveys in which blood samples are collected during household visits, shipped using the standard civil postal service, and then frozen for subseq...

  2. Measuring high-sensitivity cardiac troponin T blood concentration in population surveys

    OpenAIRE

    Lazzarino, A. I.; Mindell, J. S.

    2017-01-01

    INTRODUCTION: The blood test for high-sensitivity cardiac troponin T (HS-CTnT) has been proposed as a marker of cardiovascular risk in the general population, as it is associated with subsequent incidence of cardiovascular events and mortality. We aimed at evaluating the feasibility of HS-CTnT testing within large nationally-representative population surveys in which blood samples are collected during household visits, shipped using the standard civil postal service, and then frozen for subse...

  3. Assessment of local changes of cerebral perfusion and blood concentration by ultrasound harmonic B-mode contrast measurement in piglet.

    NARCIS (Netherlands)

    Wijk, M.C. van; Klaessens, J.H.G.M.; Hopman, J.C.W.; Liem, K.D.; Thijssen, J.M.

    2003-01-01

    This study tested the hypothesis that changes in the blood concentration, and possibly in the perfusion, of different areas in the brain can be assessed by the use of ultrasound contrast agent (CA) and (linear) echo densitometry. The experiments were performed with piglets (n=3) under general

  4. Consumption of lead-shot cervid meat and blood lead concentrations in a group of adult Norwegians.

    Science.gov (United States)

    Meltzer, H M; Dahl, H; Brantsæter, A L; Birgisdottir, B E; Knutsen, H K; Bernhoft, A; Oftedal, B; Lande, U S; Alexander, J; Haugen, M; Ydersbond, T A

    2013-11-01

    Several recent investigations have reported high concentrations of lead in samples of minced cervid meat. This paper describes findings from a Norwegian study performed in 2012 among 147 adults with a wide range of cervid game consumption. The main aim was to assess whether high consumption of lead-shot cervid meat is associated with increased concentration of lead in blood. A second aim was to investigate to what extent factors apart from game consumption explain observed variability in blood lead levels. Median (5 and 95 percentile) blood concentration of lead was 16.6 µg/L (7.5 and 39 µg/L). An optimal multivariate linear regression model for log-transformed blood lead indicated that cervid game meat consumption once a month or more was associated with approximately 31% increase in blood lead concentrations. The increase seemed to be mostly associated with consumption of minced cervid meat, particularly purchased minced meat. However, many participants with high and long-lasting game meat intake had low blood lead concentrations. Cervid meat together with number of bullet shots per year, years with game consumption, self-assembly of bullets, wine consumption and smoking jointly accounted for approximately 25% of the variation in blood lead concentrations, while age and sex accounted for 27% of the variance. Blood lead concentrations increased approximately 18% per decade of age, and men had on average 30% higher blood lead concentrations than women. Hunters who assembled their own ammunition had 52% higher blood lead concentrations than persons not making ammunition. In conjunction with minced cervid meat, wine intake was significantly associated with increased blood lead. Our results indicate that hunting practices such as use of lead-based ammunition, self-assembling of lead containing bullets and inclusion of lead-contaminated meat for mincing to a large extent determine the exposure to lead from cervid game consumption. © 2013 Elsevier Inc. All rights

  5. Trace-element measurement in human blood samples

    International Nuclear Information System (INIS)

    Hamidian, M.R.; Ebrahimi-Fakhar, F.

    1992-01-01

    It is conceivable that some essential elements such as zinc, iron, calcium, copper, phosphorus, selenium, etc., have a major impact on biological and metabolical functions in the human body. The concentration of these elements is normally very minute and changes within a naturally set tolerance. The accurate measurement of these elements in biological samples, such as in blood, is one of the objectives of medical physics in diagnosis. There are many sophisticated methods to measure the accurate amount of each element in biological samples. The methods used in this project are a combination of proton-induced X-ray emission (PIXE) and neutron activation analysis (NAA). The PIXE and NAA are fast and reliable techniques for multielement analysis at the level of parts per million and less

  6. Blood glucose measurement with multiple quantum cascade lasers using hollow-optical fiber-based ATR spectroscopy

    Science.gov (United States)

    Yoshioka, K.; Kino, S.; Matsuura, Y.

    2018-02-01

    For non-invasive blood glucose measurement, a measurement system based on mid-infrared ATR spectroscopy equipped with a combination of a QCL as a light source and a hollow-optical fiber as a beam delivery medium is developed. Firstly the measurement sensitivity of the system is evaluated by using glucose solutions and the result shows a significant correlation between optical absorbance and solution concentration. It is also confirmed that the system has a sensitivity that is enough for blood glucose measurement. Then optical absorption of human lips in the mid-infrared wavelength region is measured using a QCL with a wavenumber of 1080 cm-1 where human tissue exhibits strong absorption of glucose and its metabolites. As a result, the measured absorption follows the change of blood glucose well with a time delay of around 10 minutes and correlation factor between the absorbance and the blood glucose level is 0.42.

  7. Cadmium, lead and mercury concentrations and their influence on morphological parameters in blood donors from different age groups from southern Poland.

    Science.gov (United States)

    Janicka, Monika; Binkowski, Łukasz J; Błaszczyk, Martyna; Paluch, Joanna; Wojtaś, Włodzimierz; Massanyi, Peter; Stawarz, Robert

    2015-01-01

    Due to industrial development, environmental contamination with metals increases which leads to higher human exposure via air, water and food. In order to evaluate the level of the present exposition, the concentrations of metals can be measured in such biological materials as human blood. In this study, we assessed the concentrations of cadmium (Cd), mercury (Hg) and lead (Pb) in blood samples from male blood donors from southern Poland (Europe) born in 1994 (n=30) and between 1947 and 1955 (n=30). Higher levels of Pb were seen in the group of older men (4.48 vs 2.48μg/L), whereas the Hg levels were lower (1.78 vs 4.28μg/L). Cd concentrations did not differ between age groups (0.56μg/L). The levels of Cd and Pb in older donors were significantly correlated (Spearman R 0.5135). We also observed a positive correlation between the number of red blood cells (RBC) and Hg concentrations in the older group (Spearman R 0.4271). Additionally, we noted numerous correlations among morphological parameters. Based on our results, we can state that metals influence the blood morphology and their concentrations in blood vary among age groups. Copyright © 2014 Elsevier GmbH. All rights reserved.

  8. Blood harmane concentrations and dietary protein consumption in essential tremor.

    Science.gov (United States)

    Louis, E D; Zheng, W; Applegate, L; Shi, L; Factor-Litvak, P

    2005-08-09

    Beta-carboline alkaloids (e.g., harmane) are highly tremorogenic chemicals. Animal protein (meat) is the major dietary source of these alkaloids. The authors previously demonstrated that blood harmane concentrations were elevated in patients with essential tremor (ET) vs controls. Whether this difference is due to greater animal protein consumption by patients or their failure to metabolize harmane is unknown. The aim of this study was to determine whether patients with ET and controls differ with regard to 1) daily animal protein consumption and 2) the correlation between animal protein consumption and blood harmane concentration. Data on current diet were collected with a semiquantitative food frequency questionnaire and daily calories and consumption of animal protein and other food types was calculated. Blood harmane concentrations were log-transformed (logHA). The mean logHA was higher in 106 patients than 161 controls (0.61 +/- 0.67 vs 0.43 +/- 0.72 g(-10)/mL, p = 0.035). Patients and controls consumed similar amounts of animal protein (50.2 +/- 19.6 vs 49.4 +/- 19.1 g/day, p = 0.74) and other food types (animal fat, carbohydrates, vegetable fat) and had similar caloric intakes. In controls, logHA was correlated with daily consumption of animal protein (r = 0.24, p = 0.003); in patients, there was no such correlation (r = -0.003, p = 0.98). The similarity between patients and controls in daily animal protein consumption and the absence of the normal correlation between daily animal protein consumption and logHA in patients suggests that another factor (e.g., a metabolic defect) may be increasing blood harmane concentration in patients.

  9. Effect of hemoglobin adjustment on the precision of mercury concentrations in maternal and cord blood

    DEFF Research Database (Denmark)

    Kim, Byung Mi; Choi, Anna L.; Ha, Eun Hee

    2014-01-01

    to be less precise than suggested by laboratory quality data, we studied the interrelationships of mercury concentrations with hemoglobin in paired maternal and cord blood samples from a Faroese birth cohort (N=514) and the Mothers and Children[U+05F3]s Environmental Health study in Korea (n=797). Linear...... and cord blood for hemoglobin improved their precision, while no significant effect of the selenium concentration in maternal blood was found. Adjustment of blood-mercury concentrations for hemoglobin is therefore recommended. © 2014 Elsevier Inc....

  10. Carbohydrate ingestion before and during soccer match play and blood glucose and lactate concentrations.

    Science.gov (United States)

    Russell, Mark; Benton, David; Kingsley, Michael

    2014-01-01

    The ingestion of carbohydrate (CHO) before and during exercise and at halftime is commonly recommended to soccer players for maintaining blood glucose concentrations throughout match play. However, an exercise-induced rebound glycemic response has been observed in the early stages of the second half of simulated soccer-specific exercise when CHO-electrolyte beverages were consumed regularly. Therefore, the metabolic effects of CHO beverage consumption throughout soccer match play remain unclear. To investigate the blood glucose and blood lactate responses to CHOs ingested before and during soccer match play. Crossover study. Applied research study. Ten male outfield academy soccer players (age = 15.6 ± 0.2 years, height = 1.74 ± 0.02 m, mass = 65.3 ± 1.9 kg, estimated maximal oxygen consumption = 58.4 ± 0.8 mL·kg(-1)·min(-1)). Players received a 6% CHO-electrolyte solution or an electrolyte (placebo) solution 2 hours before kickoff, before each half (within 10 minutes), and every 15 minutes throughout exercise. Blood samples were obtained at rest, every 15 minutes during the match (first half: 0-15, 15-30, and 30-45 minutes; second half: 45-60, 60-75, and 75-90 minutes) and 10 minutes into the halftime break. Metabolic responses (blood glucose and blood lactate concentrations) and markers of exercise intensity (heart rate) were recorded. Supplementation influenced the blood glucose response to exercise (time × treatment interaction effect: P ≤ .05), such that glucose concentrations were higher at 30 to 45 minutes in the CHO than in the placebo condition. However, in the second half, blood glucose concentrations were similar between conditions because of transient reductions from peak values occurring in both trials at halftime. Blood lactate concentrations were elevated above those at rest in the first 15 minutes of exercise (time-of-sample effect: P interaction effect: P = .49). Ingestion of a 6% CHO-electrolyte beverage before and during soccer match

  11. Postmortem Blood Concentrations of R- and S-Enantiomers of Methadone and EDDP in Drug Users: Influence of Co-Medication and P-glycoprotein Genotype

    DEFF Research Database (Denmark)

    Buchard, Anders; Linnet, Kristian; Johansen, Sys Stybe

    2010-01-01

    We investigated toxicological and pharmacogenetic factors that could influence methadone toxicity using postmortem samples. R- and S-methadone were measured in femoral blood from 90 postmortem cases, mainly drug users. The R-enantiomer concentrations significantly exceeded that of the S-enantiome......We investigated toxicological and pharmacogenetic factors that could influence methadone toxicity using postmortem samples. R- and S-methadone were measured in femoral blood from 90 postmortem cases, mainly drug users. The R-enantiomer concentrations significantly exceeded that of the S...

  12. Nitrate-Rich Vegetables Increase Plasma Nitrate and Nitrite Concentrations and Lower Blood Pressure in Healthy Adults.

    Science.gov (United States)

    Jonvik, Kristin L; Nyakayiru, Jean; Pinckaers, Philippe Jm; Senden, Joan Mg; van Loon, Luc Jc; Verdijk, Lex B

    2016-05-01

    Dietary nitrate is receiving increased attention due to its reported ergogenic and cardioprotective properties. The extent to which ingestion of various nitrate-rich vegetables increases postprandial plasma nitrate and nitrite concentrations and lowers blood pressure is currently unknown. We aimed to assess the impact of ingesting different nitrate-rich vegetables on subsequent plasma nitrate and nitrite concentrations and resting blood pressure in healthy normotensive individuals. With the use of a semirandomized crossover design, 11 men and 7 women [mean ± SEM age: 28 ± 1 y; mean ± SEM body mass index (BMI, in kg/m(2)): 23 ± 1; exercise: 1-10 h/wk] ingested 4 different beverages, each containing 800 mg (∼12.9 mmol) nitrate: sodium nitrate (NaNO3), concentrated beetroot juice, a rocket salad beverage, and a spinach beverage. Plasma nitrate and nitrite concentrations and blood pressure were determined before and up to 300 min after beverage ingestion. Data were analyzed using repeated-measures ANOVA. Plasma nitrate and nitrite concentrations increased after ingestion of all 4 beverages (P nitrate concentrations were similar for all treatments (all values presented as means ± SEMs: NaNO3: 583 ± 29 μmol/L; beetroot juice: 597 ± 23 μmol/L; rocket salad beverage: 584 ± 24 μmol/L; spinach beverage: 584 ± 23 μmol/L). Peak plasma nitrite concentrations were different between treatments (NaNO3: 580 ± 58 nmol/L; beetroot juice: 557 ± 57 nmol/L; rocket salad beverage: 643 ± 63 nmol/L; spinach beverage: 980 ± 160 nmol/L; P = 0.016). When compared with baseline, systolic blood pressure declined 150 min after ingestion of beetroot juice (from 118 ± 2 to 113 ± 2 mm Hg; P nitrate-rich beetroot juice, rocket salad beverage, and spinach beverage effectively increases plasma nitrate and nitrite concentrations and lowers blood pressure to a greater extent than sodium nitrate. These findings show that nitrate-rich vegetables can be used as dietary nitrate

  13. Blood and dried blood spot telomere length measurement by qPCR: assay considerations.

    Directory of Open Access Journals (Sweden)

    DeAnna L Zanet

    Full Text Available Measurement of telomere length is crucial for the study of telomere maintenance and its role in molecular pathophysiology of diseases and in aging. Several methods are used to measure telomere length, the choice of which usually depends on the type and size of sample to be assayed, as well as cost and throughput considerations. The goal of this study was to investigate the factors that may influence the reliability of qPCR-based relative telomere length measurements in whole blood. Day to day intra-individual variability, types of blood anticoagulant, sample storage conditions, processing and site of blood draw were investigated. Two qPCR-based methods to measure telomere length (monoplex vs. multiplex were also investigated and showed a strong correlation between them. Freezing and thawing of the blood and storage of the blood at 4°C for up to 4 days did not affect telomere length values. Telomere lengths in dried blood spots were significantly higher than both whole blood and peripheral mononuclear blood cells, and were highly correlated with both. We found that telomere length measurements were significantly higher in dried blood spots collected directly from fingertip prick compared to dried blood spots prepared with anticoagulated whole blood collected from the finger, and non-blotted whole blood taken from both finger and arm venipuncture. This suggests that DNA from cells blotted on paper is not equivalent to that collected from venipuncture whole blood, and caution should be taken when comparing between blood sample types.

  14. Blood Glucose and Insulin Concentrations after Octreotide Administration in Horses With Insulin Dysregulation.

    Science.gov (United States)

    Frank, N; Hermida, P; Sanchez-Londoño, A; Singh, R; Gradil, C M; Uricchio, C K

    2017-07-01

    Octreotide is a somatostatin analog that suppresses insulin secretion. We hypothesized that octreotide would suppress insulin concentrations in horses and that normal (N) horses and those with insulin dysregulation (ID) would differ significantly in their plasma glucose and insulin responses to administration of octreotide. Twelve horses, N = 5, ID = 7. Prospective study. An oral sugar test was performed to assign horses to N and ID groups. Octreotide (1.0 μg/kg IV) was then administered, and blood was collected at 0, 5, 10, 15, 20, 25, 30, 45, 60, 75, and 90 minute, and 2, 3, 4, 6, 8, 12, and 24 hour for measurement of glucose and insulin concentrations. Area under the curve (AUC) values were calculated. Mean AUC values for glucose and insulin did not differ between normal (n = 5) and ID (n = 7) groups after octreotide injection. Significant time (P glucose and insulin concentrations. A group × time interaction (P = .091) was detected for insulin concentrations after administration of octreotide, but the group (P = .33) effect was not significant. Octreotide suppresses insulin secretion, resulting in hyperglycemia, and then concentrations increase above baseline as glycemic control is restored. Our hypothesis that octreotide causes insulin concentrations to decrease in horses was supported, but differences between N and ID groups did not reach statistical significance when blood glucose and insulin responses were compared. The utility of an octreotide response test remains to be determined. Copyright © 2017 The Authors. Journal of Veterinary Internal Medicine published by Wiley Periodicals, Inc. on behalf of the American College of Veterinary Internal Medicine.

  15. Concentrations of selenium, mercury, and lead in blood of emperor geese in western Alaska

    Science.gov (United States)

    Franson, J.C.; Schmutz, J.A.; Creekmore, L.H.; Fowler, A.C.

    1999-01-01

    We found up to 10 ppm wet weight of selenium in blood samples collected from emperor geese (Chen canagica) on their breeding grounds on the Yukon‐Kuskokwim Delta in western Alaska, USA. Incubating adult females captured in late May through mid‐June 1997 had significantly higher concentrations of selenium in their blood (mean = 5.60 ppm) than adult females captured during wing molt in late July 1996 (mean = 2.78 ppm). Females that nested early or were in good body condition had higher concentrations of selenium in their blood than did other nesting females. Blood samples from 4 of 29 goslings had detectable levels of selenium (mean = 0.14 ppm). Our findings suggest that emperor geese are exposed to more selenium in the marine environment of their wintering and staging areas on the Alaska Peninsula than on the breeding grounds. The highest concentration of mercury found in the blood of emperor geese was 0.24 ppm. One bird had a blood lead concentration of 0.67 ppm, but 82% had no detectable lead in their blood, suggesting that lead exposure from the ingestion of lead shot poses little threat for emperor geese in western Alaska, contrary to findings reported for sympatric spectacled eiders (Somateria fischeri).

  16. What Happens to Blood Glucose Concentrations After Oral Treatment for Neonatal Hypoglycemia?

    Science.gov (United States)

    Harris, Deborah L; Gamble, Greg D; Weston, Philip J; Harding, Jane E

    2017-11-01

    To determine the change in blood glucose concentration after oral treatment of infants with hypoglycemia in the first 48 hours after birth. We analyzed data from 227 infants with hypoglycemia (blood glucose dextrose or placebo gel plus feeding with formula, expressed breast milk, or breast feeding. The overall mean increase in blood glucose concentration was 11.7 mg/dL (95% CI 10.4-12.8). The increase was greater after buccal dextrose gel than after placebo gel (+3.0 mg/dL; 95% CI 0.7-5.3; P = .01) and greater after infant formula than after other feedings (+3.8 mg/dL; 95% CI 0.8-6.7; P = .01). The increase in blood glucose concentration was not affected by breast feeding (+2.0 mg/dL; 95% CI -0.3 to 44.2; P = .09) or expressed breast milk (-1.4 mg/dL; 95% CI -3.7 to 0.9; P = .25). However, breast feeding was associated with reduced requirement for repeat gel treatment (OR = 0.52; 95% CI 0.28-0.94; P = .03). Treatment of infants with hypoglycemia with dextrose gel or formula is associated with increased blood glucose concentration and breast feeding with reduced need for further treatment. Dextrose gel and breast feeding should be considered for first-line oral treatment of infants with hypoglycemia. Copyright © 2017 Elsevier Inc. All rights reserved.

  17. Home blood pressure measurement in elderly patients with cognitive impairment: comparison of agreement between relative-measured blood pressure and automated blood pressure measurement.

    Science.gov (United States)

    Plichart, Matthieu; Seux, Marie-Laure; Caillard, Laure; Chaussade, Edouard; Vidal, Jean-Sébastien; Boully, Clémence; Hanon, Olivier

    2013-08-01

    Home blood pressure measurement (HBPM) is recommended by guidelines for hypertension management. However, this method might be difficult to use in elderly individuals with cognitive disorders. Our aim was to assess the agreement and the feasibility of HBPM by a relative as compared with 24-h ambulatory blood pressure monitoring (ABPM) in elderly patients with dementia. Sixty outpatients with dementia aged 75 years and older with office hypertension (≥140/90 mmHg) were subjected successively to HBPM by a trained relative and 24-h ABPM. The order of the two methods was randomized. Current guidelines' thresholds for the diagnosis of hypertension were used. The mean (SD) age of the patients was 80.8 (6.1) years (55% women) and the mean (SD) mini-mental state examination score was 20.1 (6.9). The feasibility of relative-HBPM was very high, with a 97% success rate (defined by ≥12/18 measurements reported). The blood pressure measurements were highly correlated between the two methods (r=0.75 and 0.64 for systolic blood pressure and diastolic blood pressure, respectively; Pmethods for the diagnosis of sustained hypertension and white-coat hypertension was excellent (overall agreement, 92%; κ coefficient, 0.81; 95% CI, 0.61-0.93). Similar results were found for daytime-ABPM. In cognitively impaired elderly patients, HBPM by a relative using an automated device was a good alternative to 24-h ABPM.

  18. [Comparison of invasive blood pressure measurement in the aorta with indirect oscillometric blood pressure measurement at the wrist and forearm].

    Science.gov (United States)

    Saul, F; Aristidou, Y; Klaus, D; Wiemeyer, A; Lösse, B

    1995-09-01

    Indirectly measured blood pressure at the wrist or upper arm was compared with directly measured values in the aortic arch during routinely performed diagnostic cardiac catheterization in 100 patients (31-80 years, mean 59.3 years, 60% males). The noninvasive measurements were carried out by oscillometric devices, NAiS Blood Pressure Watch for measurements at the wrist, and Hestia OZ80 at the upper arm. Systolic blood pressure measured at the wrist was 4.3 +/- 14.1 mm Hg, and the diastolic value 6.0 +/- 8.9 mm Hg higher than when measured at the aortic arch; the difference was significant in both cases. Correlation coefficients were 0.85 for systolic and 0.71 for diastolic blood pressure. In 16% of the patients the systolic blood pressure at the wrist differed more than +/- 20 mm Hg. The diastolic blood pressure at the wrist measured more than +/- 20 mm Hg higher than in the aorta in 5% of the patients. At the upper arm mean systolic values were not different to the aorta. The diastolic pressure was 9.3 +/- 9.8 mm Hg higher in the aorta than at the upper arm. To verify the accuracy of values measured with the NAiS Blood Pressure Watch compared with the standard technique at the upper arm, sequential measurements were made at wrist and ipsilateral upper arm in the same group of 100 patients. The systolic blood pressure at the left wrist was 3.4 +/- 13.3 mm Hg higher and the diastolic pressure 3.8 +/- 9.5 mm Hg lower than at the upper arm. Only 53% of systolic values lay within a range of +/- 10 mm Hg. The correspondence between wrist and upper arm values was better for diastolic blood pressure, the values differing by less than +/- 10 mm Hg in two-thirds of patients. Self-measurement of arterial blood pressure with an oscillometric device at the wrist can be recommended only in individual cases with a difference of simultaneously measured values at the upper arm of less than +/- 10 mm Hg for systolic and diastolic blood pressures. The standard method for indirectly

  19. Thyroid Hormone and Blood Metabolites Concentration of Gilts Superovulated Prior to Mating

    Directory of Open Access Journals (Sweden)

    RA Mege

    2009-05-01

    Full Text Available An experiment was conducted to study injection of pregnant mare serum gonadotrophin (PMSG and human chorionic gonadotrophin (hCG as superovulation agent in gilts to improve thyroid hormone and blood metabolites concentraton. In this experiment, 48 gilts were assigned into four groups of twelve gilts injected with PMSG dan hCG dose levels of 0, 600, 1200 and 1800 IU/gilt. Injections were conducted three days before estrus. During gestation, gilts were placed in colony pigpen. On days 15, 35, and 70 of gestation blood collected to determine triiodothyronine, tetraiodothyronine, tryglicerides, glucose, protein and bood nitrogen urea concentration. The resuts showed that superovulation dose levels of 600 to 1200 IU/gilt increased concentration of thyroid hormone (triiodothyronine and tetraiodothyronine/thyroxin and blood metabolite (triglycerides, glucose, and protein, but decreased blood urea nitrogen in gestation ages 15, 35, and 70 days. It is concluded that superovulation with dose of 600 to 1200 IU can improve of gilts metabolite hormone and blood metabolites. (Animal Production 11(2: 88-95 (2009Key Words: gilts, superovulation, metabolite hormone, blood metabolites

  20. First measurement of radon transfer. Water - skin - blood - air

    International Nuclear Information System (INIS)

    Philipsborn, H. von; Grunewald, W.A.

    2000-01-01

    While radon is disliked in uranium mines and homes, it is used medically in radon spas for the treatment of several ailments. The transfer of radon gas from water, through skin into blood and into expiratory air was studied completely for the first time for a person resting 20-30 min in radon water. For waterborne radon concentrations of 1500±100 Bq/L, 4±1 Bq/L were measured in the blood and 2.4±0.5 kBq/m 3 (Bq/L) in the expiratory air. The results can be understood according to the principles of physiology. The nature of the experiments excluded persons other than the authors. Hence the study has been radiometric (physical), not clinical (medical). (orig.)

  1. Perfluoroalkyl Acid Concentrations in Blood Samples Subjected to Transportation and Processing Delay

    DEFF Research Database (Denmark)

    Bach, Cathrine Carlsen; Henriksen, Tine Brink; Bossi, Rossana

    2015-01-01

    and transportation prior to processing and samples with immediate processing and freezing. METHODS: Pregnant women recruited at Aarhus University Hospital, Denmark, (n = 88) provided paired blood samples. For each pair of samples, one was immediately processed and plasma was frozen, and the other was delayed...... and transported as whole blood before processing and freezing of plasma (similar to the Danish National Birth Cohort). We measured 12 perfluoroalkyl acids and present results for compounds with more than 50% of samples above the lower limit of quantification. RESULTS: For samples taken in the winter, relative...... differences between the paired samples ranged between -77 and +38% for individual perfluoroalkyl acids. In most cases concentrations were lower in the delayed and transported samples, e.g. the relative difference was -29% (95% confidence interval -30; -27) for perfluorooctane sulfonate. For perfluorooctanoate...

  2. Blood pressure and anthropometric measurements in healthy ...

    African Journals Online (AJOL)

    Methods. We measured the blood pressures of 650 healthy, randomly ... In addition, blood pressure measurement should be a part of the routine clinical examination of children. ... familial risk factors.2 ... common cause of elevated blood pressure in children.4 They ... sphygmomanometer (Accoson, hospital model BS 274,.

  3. Association between the blood concentrations of ammonia and carnitine/amino acid of schizophrenic patients treated with valproic acid.

    Science.gov (United States)

    Ando, Masazumi; Amayasu, Hideaki; Itai, Takahiro; Yoshida, Hisahiro

    2017-01-01

    Administration of valproic acid (VPA) is complicated with approximately 0.9% of patients developing hyperammonemia, but the pathogenesis of this adverse effect remains to be clarified. The aim of the present study was to search for mechanisms associated with VPA-induced hyperammonemia in the light of changes in serum amino acids concentrations associated with the urea cycle of schizophrenic patients. Blood samples (10 mL) were obtained from 37 schizophrenic patients receiving VPA for the prevention of violent behaviors in the morning after overnight fast. Blood concentrations of ammonia, VPA, free carnitine, acyl-carnitine, and 40 amino acids including glutamate and citrulline were measured for each patient. Univariate and multivariate regression analyses were performed to identify amino acids or concomitantly administered drugs that were associated with variability in the blood concentrations of ammonia. The blood ammonia level was positively correlated with the serum glutamate concentration ( r  = 0.44, p  < 0.01) but negatively correlated with glutamine ( r  = -0.41, p  = 0.01), citrulline ( r  = -0.42, p  = 0.01), and glycine concentrations ( r  = -0.54, p  < 0.01). It was also revealed that the concomitant administration of the mood stabilizers ( p  = 0.04) risperidone ( p  = 0.03) and blonanserin ( p  < 0.01) was positively associated with the elevation of the blood ammonia level. We hypothisized that VPA would elevate the blood ammonia level of schizophrenic patients. The observed changes in serum amino acids are compatible with urea cycle dysfunction, possibly due to reduced carbamoyl-phosphate synthase 1 (CPS1) activity. We conclude that VPA should be prudently prescribed to schizophrenic patients, particularly those receiving mood stabilizers or certain antipsychotics.

  4. The effect of single low-dose dexamethasone on blood glucose concentrations in the perioperative period: a randomized, placebo-controlled investigation in gynecologic surgical patients.

    Science.gov (United States)

    Murphy, Glenn S; Szokol, Joseph W; Avram, Michael J; Greenberg, Steven B; Shear, Torin; Vender, Jeffery S; Gray, Jayla; Landry, Elizabeth

    2014-06-01

    The effect of single low-dose dexamethasone therapy on perioperative blood glucose concentrations has not been well characterized. In this investigation, we examined the effect of 2 commonly used doses of dexamethasone (4 and 8 mg at induction of anesthesia) on blood glucose concentrations during the first 24 hours after administration. Two hundred women patients were randomized to 1 of 6 groups: Early-control (saline); Early-4 mg (4 mg dexamethasone); Early-8 mg (8 mg dexamethasone); Late-control (saline); Late-4 mg (4 mg dexamethasone); and Late-8 mg (8 mg dexamethasone). Blood glucose concentrations were measured at baseline and 1, 2, 3, and 4 hours after administration in the early groups and at baseline and 8 and 24 hours after administration in the late groups. The incidence of hyperglycemic events (the number of patients with at least 1 blood glucose concentration >180 mg/dL) was determined. Blood glucose concentrations increased significantly over time in all control and dexamethasone groups (from median baselines of 94 to 102 mg/dL to maximum medians ranging from 141 to 161.5 mg/dL, all P < 0.001). Blood glucose concentrations did not differ significantly between the groups receiving dexamethasone (either 4 or 8 mg) and those receiving saline at any measurement time. The incidence of hyperglycemic events did not differ in any of the early (21%-28%, P = 0.807) or late (13%-24%, P = 0.552) groups. Because blood glucose concentrations during the first 24 hours after administration of single low-dose dexamethasone did not differ from those observed after saline administrations, these results suggest clinicians need not avoid using dexamethasone for nausea and vomiting prophylaxis out of concerns related to hyperglycemia.

  5. Assessing pharmacy students' ability to accurately measure blood pressure using a blood pressure simulator arm.

    Science.gov (United States)

    Bottenberg, Michelle M; Bryant, Ginelle A; Haack, Sally L; North, Andrew M

    2013-06-12

    To compare student accuracy in measuring normal and high blood pressures using a simulator arm. In this prospective, single-blind, study involving third-year pharmacy students, simulator arms were programmed with prespecified normal and high blood pressures. Students measured preset normal and high diastolic and systolic blood pressure using a crossover design. One hundred sixteen students completed both blood pressure measurements. There was a significant difference between the accuracy of high systolic blood pressure (HSBP) measurement and normal systolic blood pressure (NSBP) measurement (mean HSBP difference 8.4 ± 10.9 mmHg vs NSBP 3.6 ± 6.4 mmHg; pdifference between the accuracy of high diastolic blood pressure (HDBP) measurement and normal diastolic blood pressure (NDBP) measurement (mean HDBP difference 6.8 ± 9.6 mmHg vs. mean NDBP difference 4.6 ± 4.5 mmHg; p=0.089). Pharmacy students may need additional instruction and experience with taking high blood pressure measurements to ensure they are able to accurately assess this important vital sign.

  6. Assessing Pharmacy Students’ Ability to Accurately Measure Blood Pressure Using a Blood Pressure Simulator Arm

    Science.gov (United States)

    Bryant, Ginelle A.; Haack, Sally L.; North, Andrew M.

    2013-01-01

    Objective. To compare student accuracy in measuring normal and high blood pressures using a simulator arm. Methods. In this prospective, single-blind, study involving third-year pharmacy students, simulator arms were programmed with prespecified normal and high blood pressures. Students measured preset normal and high diastolic and systolic blood pressure using a crossover design. Results. One hundred sixteen students completed both blood pressure measurements. There was a significant difference between the accuracy of high systolic blood pressure (HSBP) measurement and normal systolic blood pressure (NSBP) measurement (mean HSBP difference 8.4 ± 10.9 mmHg vs NSBP 3.6 ± 6.4 mmHg; pdifference between the accuracy of high diastolic blood pressure (HDBP) measurement and normal diastolic blood pressure (NDBP) measurement (mean HDBP difference 6.8 ± 9.6 mmHg vs. mean NDBP difference 4.6 ± 4.5 mmHg; p=0.089). Conclusions. Pharmacy students may need additional instruction and experience with taking high blood pressure measurements to ensure they are able to accurately assess this important vital sign. PMID:23788809

  7. Post mortem concentrations of endogenous gamma hydroxybutyric acid (GHB) and in vitro formation in stored blood and urine samples.

    Science.gov (United States)

    Busardò, Francesco Paolo; Bertol, Elisabetta; Vaiano, Fabio; Baglio, Giovanni; Montana, Angelo; Barbera, Nunziata; Zaami, Simona; Romano, Guido

    2014-10-01

    Gamma-hydroxybutyrate (GHB) is a central nervous system depressant, primarily used as a recreational drug of abuse with numerous names. It has also been involved in various instances of drug-facilitated sexual assault due to its potential incapacitating effects. The first aim of this paper is to measure the post-mortem concentration of endogenous GHB in whole blood and urine samples of 30 GHB free-users, who have been divided according to the post-mortem interval (PMI) in three groups (first group: 24-36h; second group: 37-72h; third group: 73-192h), trying to evaluate the role of PMI in affecting post mortem levels. Second, the Authors have evaluated the new formation of GHB in vitro in blood and urine samples of the three groups, which have been stored at -20°C, 4°C and 20°C over a period of one month. The concentrations were measured by GC-MS after liquid-liquid extraction according to the method validated and published by Elliot (For. Sci. Int., 2003). For urine samples, GHB concentrations were creatinine-normalized. In the first group the GHB mean concentration measured after autopsy was: 2.14mg/L (range 0.54-3.21mg/L) in blood and 3.90mg/g (range 0.60-4.81mg/g) in urine; in the second group it was: 5.13mg/L (range 1.11-9.60mg/L) in blood and 3.93mg/g (range 0.91-7.25mg/g) in urine; in the third group it was: 11.8mg/L (range 3.95-24.12mg/L) in blood and 9.83mg/g (range 3.67-21.90mg/g) in urine. The results obtained in blood and urine samples showed a statistically significant difference among groups (pblood and urine samples a mean difference at 20°C compared to -20°C not statistically significant at the 10% level. These findings allow us to affirm that the PMI strongly affects the post mortem production of GHB in blood and urine samples. Regarding the new formation of GHB in vitro both in blood and urine samples of the three groups, which have been stored at -20°C, 4°C and 20°C over a period of one month, although there was no significant increases of

  8. Power law relation between particle concentrations and their sizes in the blood plasma

    International Nuclear Information System (INIS)

    Kirichenko, M N; Chaikov, L L; Zaritskii, A R

    2016-01-01

    This work is devoted to the investigation of sizes and concentrations of particles in blood plasma by dynamic light scattering (DLS). Blood plasma contains many different proteins and their aggregates, microparticles and vesicles. Their sizes, concentrations and shapes can give information about donor's health. Our DLS study of blood plasma reveals unexpected dependence: with increasing of the particle sizes r (from 1 nm up to 1 μm), their concentrations decrease as r -4 (almost by 12 orders). We found also that such dependence was repeated for model solution of fibrinogen and thrombin with power coefficient is -3,6. We believe that this relation is a fundamental law of nature that shows interaction of proteins (and other substances) in biological liquids. (paper)

  9. Blood mercury concentration, fish consumption and anthropometry in Chinese children: A national study.

    Science.gov (United States)

    Gao, Zhen-Yan; Li, Min-Ming; Wang, Ju; Yan, Jin; Zhou, Can-Can; Yan, Chong-Huai

    2018-01-01

    This study sought to obtain national cross-sectional data for blood mercury levels and risk factors for mercury exposure in Chinese children aged 0 to 6years to provide evidence to support preventive measures for reducing childhood blood mercury levels. A multi-stage, stratified, clustered random sampling survey was conducted May 2013-Mar 2015. Shanghai, Jilin, Shanxi, Guangdong, Qinghai, Yunnan and Hubei, which are located in seven different geographical regions in China, were selected as the study field. A total of 14,202 children aged 0-6years participated in the study. Whole-blood venous samples (3ml) were collected from the subjects for mercury exposure assessment. The DMA-80 was applied for mercury detection, and a health questionnaire gathering information on related confounders was completed by the subjects' parents of the subjects after they received guidance from the investigators. A general linear model was used for the primary descriptive statistical analysis. Odds ratios (ORs) and 95%CIs for the risk factors were estimated using unconditional logistic regression. A total of 14,202 eligible samples were collected. The mean mercury level was 1.39μg/L. Other results were as follows: median 1.23μg/L, p25 0.86μg/L, p75 1.73μg/L, and GM 1.10μg/L. Of the seven geographical regions, Qinghai, in northwestern China, had a median mercury level of 0.37μg/L, which was significantly lower than the mercury level in Guangdong, in southeastern China (2.01μg/L). The median blood mercury level of children in suburban areas was 1.34μg/L, which was remarkably higher than that of children in rural areas (1.09μg/L). Dichotomous subgroups were generated using the median mercury concentration. Unconditional logistic regression analysis revealed that fish consumption may contribute to increased blood mercury levels (pmercury concentrations and the children's anthropometric characteristics (BMI; pmercury concentrations among Chinese children aged 0-6years were

  10. Blood gas sample spiking with total parenteral nutrition, lipid emulsion, and concentrated dextrose solutions as a model for predicting sample contamination based on glucose result.

    Science.gov (United States)

    Jara-Aguirre, Jose C; Smeets, Steven W; Wockenfus, Amy M; Karon, Brad S

    2018-05-01

    Evaluate the effects of blood gas sample contamination with total parenteral nutrition (TPN)/lipid emulsion and dextrose 50% (D50) solutions on blood gas and electrolyte measurement; and determine whether glucose concentration can predict blood gas sample contamination with TPN/lipid emulsion or D50. Residual lithium heparin arterial blood gas samples were spiked with TPN/lipid emulsion (0 to 15%) and D50 solutions (0 to 2.5%). Blood gas (pH, pCO2, pO2), electrolytes (Na+, K+ ionized calcium) and hemoglobin were measured with a Radiometer ABL90. Glucose concentration was measured in separated plasma by Roche Cobas c501. Chart review of neonatal blood gas results with glucose >300 mg/dL (>16.65 mmol/L) over a seven month period was performed to determine whether repeat (within 4 h) blood gas results suggested pre-analytical errors in blood gas results. Results were used to determine whether a glucose threshold could predict contamination resulting in blood gas and electrolyte results with greater than laboratory-defined allowable error. Samples spiked with 5% or more TPN/lipid emulsion solution or 1% D50 showed glucose concentration >500 mg/dL (>27.75 mmol/L) and produced blood gas (pH, pO 2 , pCO 2 ) results with greater than laboratory-defined allowable error. TPN/lipid emulsion, but not D50, produced greater than allowable error in electrolyte (Na + ,K + ,Ca ++ ,Hb) results at these concentrations. Based on chart review of 144 neonatal blood gas results with glucose >250 mg/dL received over seven months, four of ten neonatal intensive care unit (NICU) patients with glucose results >500 mg/dL and repeat blood gas results within 4 h had results highly suggestive of pre-analytical error. Only 3 of 36 NICU patients with glucose results 300-500 mg/dL and repeat blood gas results within 4 h had clear pre-analytical errors in blood gas results. Glucose concentration can be used as an indicator of significant blood sample contamination with either TPN

  11. Glucose concentration in capillary blood of dairy cows obtained by a minimally invasive lancet technique and determined with three different hand-held devices.

    Science.gov (United States)

    Mair, B; Drillich, M; Klein-Jöbstl, D; Kanz, P; Borchardt, S; Meyer, L; Schwendenwein, I; Iwersen, M

    2016-02-24

    Dairy cows have a massive demand for glucose at the onset of lactation. A poor adaption to this period leads to an excessive negative energy balance with an increased risk for ketosis and impaired animal health and production. Besides the measurement of ketones, analysing the glucose concentration in blood is reported as helpful instrument for diagnosis and differentiation of ketosis. Monitoring metabolic parameters requires multiple blood sampling. In other species, new blood sampling techniques have been introduced in which small amounts of blood are rapidly analysed using electronic hand-held devices. The objective of this study was to evaluate the suitability of capillary blood for blood glucose measurement in dairy cows using the hand-held devices FreeStyle Precision (FSP, Abbott), GlucoMen LX Plus (GLX, A. Menarini) and the WellionVet GLUCO CALEA, (WGC, MED TRUST). In total, 240 capillary blood samples were obtained from dry and fresh lactating Holstein-Friesian cows. Blood was collected from the skin of the exterior vulva by using a lancet. For method comparison, additional blood samples were taken from a coccygeal vessel and analyzed in a laboratory. Glucose concentrations measured by a standard laboratory method were defined as the criterion standard. The Pearson correlation coefficients between the glucose concentrations analyzed in capillary blood with the devices and the reference were 73% for the FSP, 81% for the GLX and 41% for the WGC. Bland-Altman plots showed biases of -18.8 mg/dL for the FSP, -11.2 mg/dL for the GLX and +20.82 mg/dL for the WGC. The optimized threshold determined by a Receiver Operating Characteristics analysis to detect hyperglycemia using the FSP was 43 mg/dL with a sensitivity (Se) and specificity (Sp) of 76 and 80%. Using the GLX and WGC optimized thresholds were 49 mg/dL (Se = 92%, Sp = 85%) and 95 mg/dL (Se = 39%, Sp = 92%). The results of this study demonstrate good performance characteristics for the GLX

  12. Blood BDNF concentrations reflect brain-tissue BDNF levels across species

    DEFF Research Database (Denmark)

    Klein, Anders B; Williamson, Rebecca; Santini, Martin A

    2011-01-01

    Brain-derived neurotrophic factor (BDNF) is involved in synaptic plasticity, neuronal differentiation and survival of neurons. Observations of decreased serum BDNF levels in patients with neuropsychiatric disorders have highlighted the potential of BDNF as a biomarker, but so far there have been...... no studies directly comparing blood BDNF levels to brain BDNF levels in different species. We examined blood, serum, plasma and brain-tissue BDNF levels in three different mammalian species: rat, pig, and mouse, using an ELISA method. As a control, we included an analysis of blood and brain tissue from...... conditional BDNF knockout mice and their wild-type littermates. Whereas BDNF could readily be measured in rat blood, plasma and brain tissue, it was undetectable in mouse blood. In pigs, whole-blood levels of BDNF could not be measured with a commercially available ELISA kit, but pig plasma BDNF levels (mean...

  13. Blood BDNF concentrations reflect brain-tissue BDNF levels across species

    DEFF Research Database (Denmark)

    Klein, Anders B; Williamson, Rebecca; Santini, Martin A

    2011-01-01

    no studies directly comparing blood BDNF levels to brain BDNF levels in different species. We examined blood, serum, plasma and brain-tissue BDNF levels in three different mammalian species: rat, pig, and mouse, using an ELISA method. As a control, we included an analysis of blood and brain tissue from......Brain-derived neurotrophic factor (BDNF) is involved in synaptic plasticity, neuronal differentiation and survival of neurons. Observations of decreased serum BDNF levels in patients with neuropsychiatric disorders have highlighted the potential of BDNF as a biomarker, but so far there have been...... conditional BDNF knockout mice and their wild-type littermates. Whereas BDNF could readily be measured in rat blood, plasma and brain tissue, it was undetectable in mouse blood. In pigs, whole-blood levels of BDNF could not be measured with a commercially available ELISA kit, but pig plasma BDNF levels (mean...

  14. Individual and environmental risk factors for high blood lead concentrations in Danish indoor shooters.

    Science.gov (United States)

    Grandahl, Kasper; Suadicani, Poul; Jacobsen, Peter

    2012-08-01

    International studies have shown blood lead at levels causing health concern in recreational indoor shooters. We hypothesized that Danish recreational indoor shooters would also have a high level of blood lead, and that this could be explained by shooting characteristics and the physical environment at the shooting range. This was an environmental case study of 58 male and female shooters from two indoor shooting ranges with assumed different ventilation and cleaning conditions. Information was obtained on general conditions including age, gender, tobacco and alcohol use, and shooting conditions: weapon type, number of shots fired, frequency of stays at the shooting range and hygiene habits. A venous blood sample was drawn to determine blood lead concentrations; 14 non-shooters were included as controls. Almost 60% of the shooters, hereof five out of 14 women, had a blood lead concentration above 0.48 micromol/l, a level causing long-term health concern. All controls had blood lead values below 0.17 micromol/l. Independent significant associations with blood lead concentrations above 0.48 micromol/l were found for shooting at a poorly ventilated range, use of heavy calibre weapons, number of shots and frequency of stays at the shooting range. A large proportion of Danish recreational indoor shooters had potentially harmful blood lead concentrations. Ventilation, amounts of shooting, use of heavy calibre weapons and stays at the shooting ranges were independently associated with increased blood lead. The technical check at the two ranges was performed by the Danish Technological Institute and costs were defrayed by the Danish Rifle Association. To pay for the analyses of blood lead, the study was supported by the The Else & Mogens Wedell-Wedellsborg Foundation. The Danish Regional Capital Scientific Ethics Committee approved the study, protocol number H-4-2010-130.

  15. Blood selenium concentrations and enzyme activities related to glutathione metabolism in wild emperor geese

    Science.gov (United States)

    Franson, J. Christian; Hoffman, David J.; Schmutz, Joel A.

    2002-01-01

    In 1998, we collected blood samples from 63 emperor geese (Chen canagica) on their breeding grounds on the Yukon-Kuskokwim Delta (YKD) in western Alaska, USA. We studied the relationship between selenium concentrations in whole blood and the activities of glutathione peroxidase and glutathione reductase in plasma. Experimental studies have shown that plasma activities of these enzymes are useful biomarkers of selenium-induced oxidative stress, but little information is available on their relationship to selenium in the blood of wild birds. Adult female emperor geese incubating their eggs in mid-June had a higher mean concentration of selenium in their blood and a greater activity of glutathione peroxidase in their plasma than adult geese or goslings that were sampled during the adult flight feathermolting period in late July and early August. Glutathione peroxidase activity was positively correlated with the concentration of selenium in the blood of emperor geese, and the rate of increase relative to selenium was greater in goslings than in adults. The activity of glutathione reductase was greatest in the plasma of goslings and was greater in molting adults than incubating females but was not significantly correlated with selenium in the blood of adults or goslings. Incubating female emperor geese had high selenium concentrations in their blood, accompanied by increased glutathione peroxidase activity consistent with early oxidative stress. These findings indicate that further study of the effects of selenium exposure, particularly on reproductive success, is warranted in this species.

  16. Blood lipid concentrations and lipoprotein patterns in captive and wild American black bears (Ursus americanus).

    Science.gov (United States)

    Frank, Nicholas; Elliott, Sarah B; Allin, Shawn B; Ramsay, Edward C

    2006-02-01

    To compare blood lipid concentrations and lipoprotein patterns for captive and wild American black bears (Ursus americanus). 7 captive and 9 wild adult (> or = 4 years old) black bears. Blood was collected from 2 groups of captive black bears (groups A and B) and 1 group of wild black bears (group C). Blood triglyceride (TG) and cholesterol concentrations were compared among groups. Plasma lipoproteins were isolated by use of a self-generating gradient of iodixanol, and lipoprotein patterns were compared between groups A and B. Captive bears (mean +/- SD, 187.8 +/- 44.4 kg) weighed significantly more than wild bears (mean, 104.8 +/- 41.4 kg), but mean body weight did not differ between groups A and B. Mean blood TG concentrations for groups B (216.8 +/- 16.0 mg/dL) and C (190.7 +/- 34.0 mg/dL) were significantly higher than that of group A (103.9 +/- 25.3 mg/dL). Mean blood cholesterol concentration was also significantly higher for group B (227.8 +/- 8.2 mg/dL) than for groups A (171.7 +/- 35.5 mg/dL) or C (190.8 +/- 26.8 mg/dL). Mean very-low-density lipoprotein TG and low-density lipoprotein cholesterol concentrations were 2- and 3-fold higher, respectively, for group B, compared with concentrations for group A. Blood lipid concentrations vary significantly among populations of black bears. Plasma lipoprotein patterns of captive bears differed significantly between colonies and may have reflected differences in diet or management practices.

  17. Seafood Consumption and Blood Mercury Concentrations in Jamaican Children With and Without Autism Spectrum Disorders

    Science.gov (United States)

    Samms-Vaughan, Maureen; Loveland, Katherine A.; Ardjomand-Hessabi, Manouchehr; Chen, Zhongxue; Bressler, Jan; Shakespeare-Pellington, Sydonnie; Grove, Megan L.; Bloom, Kari; Pearson, Deborah A.; Lalor, Gerald C.; Boerwinkle, Eric

    2014-01-01

    Mercury is a toxic metal shown to have harmful effects on human health. Several studies have reported high blood mercury concentrations as a risk factor for autism spectrum disorders (ASDs), while other studies have reported no such association. The goal of this study was to investigate the association between blood mercury concentrations in children and ASDs. Moreover, we investigated the role of seafood consumption in relation to blood mercury concentrations in Jamaican children. Based on data for 65 sex- and age-matched pairs (2–8 years), we used a General Linear Model to test whether there is an association between blood mercury concentrations and ASDs. After controlling for the child’s frequency of seafood consumption, maternal age, and parental education, we did not find a significant difference (P = 0.61) between blood mercury concentrations and ASDs. However, in both cases and control groups, children who ate certain types of seafood (i.e., salt water fish, sardine, or mackerel fish) had significantly higher (all P mercury concentration which were about 3.5 times that of children living in the US or Canada. Our findings also indicate that Jamaican children with parents who both had education up to high school are at a higher risk of exposure to mercury compared to children with at least one parent who had education beyond high school. Based on our findings, we recommend additional education to Jamaican parents regarding potential hazards of elevated blood mercury concentrations, and its association with seafood consumption and type of seafood. PMID:22488160

  18. HEMOFILTRATION AND COUPLED PLASMA FILTRATION ADSORPTION IMPACT ON TACROLIMUS BLOOD CONCENTRATION IN RENAL TRANSPLANT RECIPIENTS

    Directory of Open Access Journals (Sweden)

    A.V. Vatazin

    2014-01-01

    Full Text Available Aim. To study the effect of hemofi ltration and coupled plasma fi ltration adsorption on tacrolimus blood concentration in renal transplant recipients.Methods and results. The study included 8 renal transplant recipients. In these patients immediately after the operation was performed the coupled plasma fi ltration adsorption with hemofiltration using a cartridge Mediasorb to reduce the severity of reperfusion injury. We have found that during this extracorporeal blood correction procedure there was statistically not signifi cant decrease of tacrolimus blood concentration. However, concentration of tacrolimus remained in the therapeutic range even after the procedure and it was not signifi cantly different from the control point С0.Conclusion. Coupled plasma fi ltration adsorption is safe in renal transplant recipients and has no signifi cant impact on tacrolimus blood concentration. However, the downward trend in the concentration of tacrolimus in the course of these procedures, especially in continuous or semicontinuous mode, as well as in patients with low hematocrit and hypoalbuminemia, requires individual monitoring.

  19. The Effect of Different Types of Musculoskeletal Injuries on Blood Concentration of Serum Amyloid A in Thoroughbred Racehorses

    Science.gov (United States)

    Turło, Agnieszka; Cywińska, Anna; Czopowicz, Michał; Witkowski, Lucjan; Niedźwiedź, Artur; Słowikowska, Malwina; Borowicz, Hieronim; Jaśkiewicz, Anna; Winnicka, Anna

    2015-01-01

    Background Training-induced muscle, skeletal and joint trauma may result in acute phase response reflected by the changes in the blood concentration of serum amyloid A (SAA) in racehorses. It remains yet unclear if such systemic reaction could be triggered by sport injuries and what is the impact of different types of musculoskeletal trauma on SAA concentrations in racehorses. This study aimed to determine changes in the SAA blood concentration in racehorses with different types of injuries of musculoskeletal system. Materials and Methods The study involved 28 racehorses diagnosed after the race with bone fractures (n = 7), dorsal metacarpal disease (n = 11), joint trauma (n = 4) or tendon and muscle trauma (n = 6) and 28 healthy control racehorses. Serum samples were collected twice, between 1 and 4 days of the injury or succesful completion of the race. SAA concentration was measured using the commercial ELISA kit. Differences between mean SAA concentration in respective groups were analyzed using ANOVA and Tukey post-hoc test. Results Mean SAA concentration within the first 4 days of the injury of muscle and tendon was significantly higher than in bone fractures, dorsal metacarpal disease, joint trauma or in the healthy horses (p<0,001). There were no significant differences between the other groups. Conclusions Strain injuries of muscle and tendons can cause a moderate increase in SAA blood concentration in racehorses, reflecting the occurrence of the acute phase response. Similar reaction is not observed in the stress-related bone injuries. PMID:26466121

  20. The Effect of Different Types of Musculoskeletal Injuries on Blood Concentration of Serum Amyloid A in Thoroughbred Racehorses.

    Directory of Open Access Journals (Sweden)

    Agnieszka Turło

    Full Text Available Training-induced muscle, skeletal and joint trauma may result in acute phase response reflected by the changes in the blood concentration of serum amyloid A (SAA in racehorses. It remains yet unclear if such systemic reaction could be triggered by sport injuries and what is the impact of different types of musculoskeletal trauma on SAA concentrations in racehorses. This study aimed to determine changes in the SAA blood concentration in racehorses with different types of injuries of musculoskeletal system.The study involved 28 racehorses diagnosed after the race with bone fractures (n = 7, dorsal metacarpal disease (n = 11, joint trauma (n = 4 or tendon and muscle trauma (n = 6 and 28 healthy control racehorses. Serum samples were collected twice, between 1 and 4 days of the injury or succesful completion of the race. SAA concentration was measured using the commercial ELISA kit. Differences between mean SAA concentration in respective groups were analyzed using ANOVA and Tukey post-hoc test.Mean SAA concentration within the first 4 days of the injury of muscle and tendon was significantly higher than in bone fractures, dorsal metacarpal disease, joint trauma or in the healthy horses (p<0,001. There were no significant differences between the other groups.Strain injuries of muscle and tendons can cause a moderate increase in SAA blood concentration in racehorses, reflecting the occurrence of the acute phase response. Similar reaction is not observed in the stress-related bone injuries.

  1. Reference ranges for hematocrit and blood hemoglobin concentration during the neonatal period: data from a multihospital health care system.

    Science.gov (United States)

    Jopling, Jeffery; Henry, Erick; Wiedmeier, Susan E; Christensen, Robert D

    2009-02-01

    "Reference ranges" are developed when it is impossible or inappropriate to establish "normal ranges" by drawing blood on healthy normal volunteers. Reference ranges for the hematocrit and the blood hemoglobin concentration of newborn infants have previously been reported from relatively small sample sizes by using measurement methods that now are considered outmoded. We sought to develop reference ranges for hematocrit and hemoglobin during the neonatal period (28 days) by using very large sample sizes and modern hematology analyzers, accounting for gestational and postnatal age and gender. Data were assembled from a multihospital health care system after exclusion of patients with a high likelihood of an abnormal value and those who were receiving blood transfusions. During the interval from 22 to 40 weeks' gestation, the hematocrit and blood hemoglobin concentration increased approximately linearly. For every week advance in gestational age, the hematocrit increased by 0.64% and the hemoglobin concentration increased by 0.21 g/dL. No difference was seen on the basis of gender. During the 4-hour interval after birth, hematocrit/hemoglobin values of late preterm and term neonates (35-42 weeks' gestation) increased by 3.6% +/- 0.5% (mean +/- SD), those of neonates of 29 to 34 weeks' gestation remained unchanged, and those of hematocrit/hemoglobin occurred. The figures presented herein describe reference ranges for hematocrit and blood hemoglobin concentration during the neonatal period, accounting for gestational and postnatal age.

  2. Impact of Endogenous and Exogenous Interferences on Clinical Chemistry Parameters Measured on Blood Gas Analyzers.

    Science.gov (United States)

    Grieme, Caleb V; Voss, Dena R; Davis, Scott R; Krasowski, Matthew D

    2017-03-01

    The prevalence of hemolysis, icterus, and lipemia (HIL) was determined for residual whole blood specimens analyzed for clinical chemistry parameters on blood gas analyzers. The frequency and potential impact of exogenous interference from iodide, salicylate, and thiocyanate (metabolite of sodium nitroprusside) on analysis of whole blood chloride was also assessed. Over an approximately two month period at an academic medical center, indices for HIL were determined on Roche cobas c502 analyzers for 1,986 residual whole blood specimens that had been previously analyzed for clinical chemistry parameters on Radiometer ABL90 FLEX blood gas analyzers. To examine exogenous interferences, retrospective analysis was performed over multiple years to ascertain whether patient samples analyzed for whole blood chloride were potentially affected by interference from iodide, salicylate, or thiocyanate. Some degree of hemolysis (defined as hemolysis index of greater than 60) was present in 9.7% of the whole blood specimens. Increasing rates of hemolysis were associated with higher whole blood potassium concentrations. Nearly 60% of specimens with potassium concentrations between 6.0 and 6.9 mEq/L had hemolysis indices of 100 or greater, and 75% of specimens with a potassium concentration of 7.0 mEq/L or greater were severely hemolyzed (hemolysis index of 300 or greater). In contrast to the hemolysis results, icterus and lipemia were determined to have minimal impact on patient results. For the exogenous interferences, we did not identify any patient samples where elevated salicylate levels or pharmaceutical iodide administration overlapped with whole blood chloride analysis (out of 75,887 and 169,229 total chloride measurements, respectively). We did, however, find that for patients receiving nitroprusside therapy in the inpatient setting, whole blood chloride concentrations were significantly higher during nitroprusside therapy [106.7 +/- 6.2 mEq/L (mean, SD)] compared to before

  3. Effects of Fatty Liver Induced by Excess Orotic Acid on B-Group Vitamin Concentrations of Liver, Blood, and Urine in Rats.

    Science.gov (United States)

    Shibata, Katsumi; Morita, Nobuya; Kawamura, Tomoyo; Tsuji, Ai; Fukuwatari, Tsutomu

    2015-01-01

    Fatty liver is caused when rats are given orotic acid of the pyrimidine base in large quantities. The lack of B-group vitamins suppresses the biosynthesis of fatty acids. We investigated how orotic acid-induced fatty liver affects the concentrations of liver, blood, and urine B-group vitamins in rats. The vitamin B6 and B12 concentrations of liver, blood, and urine were not affected by orotic acid-induced fatty liver. Vitamin B2 was measured only in the urine, but was unchanged. The liver, blood, and urine concentrations of niacin and its metabolites fell dramatically. Niacin and its metabolites in the liver, blood, and urine were affected as expected. Although the concentrations of vitamin B1, pantothenic acid, folate, and biotin in liver and blood were decreased by orotic acid-induced fatty liver, these urinary excretion amounts showed a specific pattern toward increase. Generally, as for the typical urinary excretion of B-group vitamins, these are excreted when the body is saturated. However, the ability to sustain vitamin B1, pantothenic acid, folate, and biotin decreased in fatty liver, which is hypothesized as a specific phenomenon. This metabolic response might occur to prevent an abnormally increased biosynthesis of fatty acids by orotic acid.

  4. Glucose concentration and blood acid-basis status in high-yielding dairy cows during heat stress

    Directory of Open Access Journals (Sweden)

    Vujanac Ivan

    2011-01-01

    Full Text Available The objective of this work was to examine the effect of heat stress on glucose and pH values in blood of high-yielding dairy cows in the early stage of lactation, as well as to determine whether the changes in these parameters are interdependent under such conditions. An experiment was performed on high-yielding dairy cows during the summer and the spring periods. Forty cows were selected, twenty each for the two periods under investigation. In the course of the experiment, the temperature humidity index (THI was determined for the entire period of investigations, and then also the average daily THI, nightmorning THI (average value of hourly THI measured from 22h on the previous day until 10h of the current day, as well as the day-night THI (average value of hourly THI measured during the period from 10h to 22h of the current day. The pH and glucose concentration were determined in blood samples taken in the morning and afternoon of days 30, 60, and 90 of lactation during the spring and summer periods of the investigations. Based on the results for the THI, it was established that the animals were not exposed to the effect of extreme heat stress during the spring period of investigations, while they were periodically exposed to moderate but also extreme heat stress during the summer, in particular in the afternoon hours. It can be concluded from the results obtained for the blood pH that the cows were in respiratory alkalosis during the summer in the morning and afternoon hours on day 30, in the afternoon hours of days 60 and 90 of lactation, as well as in the afternoon on day 90 of lactation during the spring period of investigations. During the summer period, there were no statistically significant differences between the pH value determined in the morning and afternoon hours on day 30 of lactation, while the pH value was significantly higher in the afternoon hours than in the morning hours on days 60 and 90 of lactation. There were no

  5. Oscillometric blood pressure measurements: differences between measured and calculated mean arterial pressure.

    NARCIS (Netherlands)

    Kiers, H.D.; Hofstra, J.M.; Wetzels, J.F.M.

    2008-01-01

    Mean arterial pressure (MAP) is often used as an index of overall blood pressure. In recent years, the use of automated oscillometric blood pressure measurement devices is increasing. These devices directly measure and display MAP; however, MAP is often calculated from systolic blood pressure (SBP)

  6. Measurement of limb blood flow using technetium-labelled red blood cells

    Energy Technology Data Exchange (ETDEWEB)

    Parkin, A; Robinson, P.J.; Wiggins, P.A.; Leveson, S.H.; Salter, M.C.P.; Matthews, I.F.; Ware, F.M.

    1986-05-01

    A method for measuring blood flow below the knee during reactive hyperaemia induced by 3 min of arterial occlusion has been developed. Subjects are positioned with lower limbs within the field of view of a gamma camera and pneumatic cuffs are placed below the knees to isolate the blood and induce a hyperaemic response. The remaining blood pool is labelled with /sup 99/Tcsup(m)-labelled red cells. Blood flows have been derived from the initial gradients of time-activity curves and from equilibrium blood sampling. The technique has been validated using a tissue-equivalent leg phantom and peristaltic pump. The method has been applied to a small group of patients with peripheral vascular disease and to normal controls. The mean value (+-SD) of limb perfusion for normal controls was found to be 16.4 +- 3.0 ml/100 ml/min and for patients with intermittent claudication was 5.1 +- 2.6 ml/100 ml/min. Flow measurements are found to correlate with clinical findings and with symptoms. Reproducibility (established by repeated measurements) is high. The method is well tolerated even by patients suffering from rest pain.

  7. Modification of a two blood sample method used for measurement of GFR with 99mTc-DTPA.

    Science.gov (United States)

    Surma, Marian J; Płachcińska, Anna; Kuśmierek, Jacek

    2018-01-01

    Measurements of GFR may be performed with a slope/intercept method (S/I), using only two blood samples taken in strictly defined time points. The aim of the study was to modify this method in order to extend time intervals suitable for blood sampling. Modification was based on a variation of a Russel et al. model parameter, selection of time intervals suitable for blood sampling and assessment of uncertainty of calculated results. Archived values of GFR measurements of 169 patients with different renal function, from 5.5 to 179 mL/min, calculated with a multiple blood sample method were used. Concentrations of a radiopharmaceutical in consecutive minutes, from 60th to 190th after injection, were calculated theoretically, using archived parameters of biexponential functions describing a decrease in 99mTc-DTPA concentration in blood plasma with time. These values, together with injected activities, were treated as measurements and used for S/I clearance calculations. Next, values of S/I clearance were compared with the multiple blood sample method in order to calculate suitable values of exponent present in a Russel's model, for every combination of two blood sampling time points. A model was considered accurately fitted to measured values when SEE ≤ 3.6 mL/min. Assessments of uncertainty of obtained results were based on law of error superposition, taking into account mean square prediction error and also errors introduced by pipetting, time measurement and stochastic radioactive decay. The accepted criteria resulted in extension of time intervals suitable for blood sampling to: between 60 and 90 minutes after injection for the first sample and between 150 and 180 minutes for the second sample. Uncertainty of results was assessed as between 4 mL/min for GFR = 5-10 mL/min and 8 mL/min for GFR = 180 mL/min. Time intervals accepted for blood sampling fully satisfy nuclear medicine staff and ensure proper determination of GFR. Uncertainty of results is entirely

  8. Weekday variation in triglyceride concentrations in 1.8 million blood samples

    DEFF Research Database (Denmark)

    Jaskolowski, Jörn; Ritz, Christian; Sjödin, Anders Mikael

    2017-01-01

    BACKGROUND: Triglyceride (TG) concentration is used as a marker of cardio-metabolic risk. However, diurnal and possibly weekday variation exists in TG concentrations. OBJECTIVE: To investigate weekday variation in TG concentrations among 1.8 million blood samples drawn between 2008 and 2015 from...... variations in TG concentrations were recorded for out-patients between the age of 9 to 26 years, with up to 20% higher values on Mondays compared to Fridays (all PTriglyceride concentrations were highest after the weekend and gradually declined during the week. We suggest that unhealthy...

  9. On-chip sample preparation for complete blood count from raw blood.

    Science.gov (United States)

    Nguyen, John; Wei, Yuan; Zheng, Yi; Wang, Chen; Sun, Yu

    2015-03-21

    This paper describes a monolithic microfluidic device capable of on-chip sample preparation for both RBC and WBC measurements from whole blood. For the first time, on-chip sample processing (e.g. dilution, lysis, and filtration) and downstream single cell measurement were fully integrated to enable sample preparation and single cell analysis from whole blood on a single device. The device consists of two parallel sub-systems that perform sample processing and electrical measurements for measuring RBC and WBC parameters. The system provides a modular environment capable of handling solutions of various viscosities by adjusting the length of channels and precisely controlling mixing ratios, and features a new 'offset' filter configuration for increased duration of device operation. RBC concentration, mean corpuscular volume (MCV), cell distribution width, WBC concentration and differential are determined by electrical impedance measurement. Experimental characterization of over 100,000 cells from 10 patient blood samples validated the system's capability for performing on-chip raw blood processing and measurement.

  10. Concentrations of heavy metals (lead, manganese, cadmium) in blood and urine of former uranium workers

    International Nuclear Information System (INIS)

    Apostolova, D.; Pavlova, S.; Paskalev, Z.

    1999-01-01

    Uranium ores contain heavy metals and other stable chemical elements as oxides, hydro-carbonates, sulphates, etc. During chemical processing of ore they could be transformed into compounds soluble in biologic liquids. The purpose of this study was to determine the combined intoxication of uranium miners and millers by heavy metals and radiation. Heavy metal (lead, manganese and cadmium) concentrations in blood and urine od 149 former uranium miners and millers were determined by AAS method. Data of significantly increased lead and manganese concentration in blood (p<0.05) of two groups were established in comparison with a control group. There is no statistical significant differences in the cadmium concentrations. The lead and manganese blood levels at the uranium millers were significant higher than those of the uranium miner group (p<0.05). Tendency towards increased blood lead concentrations of uranium millers depending on the length of service was established

  11. BLOOD SELENIUM CONCENTRATION AFFECT MASTITIS AND MILK QUALITY IN DAIRY COWS

    Directory of Open Access Journals (Sweden)

    Davidov Ivana

    2013-02-01

    Full Text Available Milk quality is usually defined in terms of mastitis. Milk with somatic cell count low then 400.000/ml and visibly normal (no clots is considered high quality. Thirty Holstein cows were used in the study to determine affect blood serum selenium concentration on mastitis and milk quality. Cows received ad libitum access to potable water and daily 0.3 mg/kg inorganic selenium supplementation in food. Blood and milk samples were taken at first and sixth lactating month. Mean selenium blood serum concentrations were found to be lower within first lactating month, and then increased in the sixth lactating month. Average somatic cell count at first lactating month was 450.000/ml of milk and at sixth lactating month was 355.000/ml. On the basis of these results it can be conclude that selenium have importance in proper functioning of the mammary glands of cows, and in reducing mastitis and in improving milk quality.

  12. Validation of NIRS in measuring tissue hemoglobin concentration and oxygen saturation on ex vivo and isolated limb models

    Science.gov (United States)

    Xu, Xiaorong; Zhu, Wen; Padival, Vikram; Xia, Mengna; Cheng, Xuefeng; Bush, Robin; Christenson, Linda; Chan, Tim; Doherty, Tim; Iatridis, Angelo

    2003-07-01

    Photonify"s tissue spectrometer uses Near-Infrared Spectroscopy for real-time, noninvasive measurement of hemoglobin concentration and oxygen saturation [SO2] of biological tissues. The technology was validated by a series of ex vivo and animal studies. In the ex vivo experiment, a close loop blood circulation system was built, precisely controlling the oxygen saturation and the hemoglobin concentration of a liquid phantom. Photonify"s tissue spectrometer was placed on the surface of the liquid phantom for real time measurement and compared with a gas analyzer, considered the gold standard to measure oxygen saturation and hemoglobin concentration. In the animal experiment, the right hind limb of each dog accepted onto the study was surgically removed. The limb was kept viable by connecting the femoral vein and artery to a blood-primed extracorporeal circuit. Different concentrations of hemoglobin were obtained by adding designated amount of saline solution into the perfusion circuit. Photonify"s tissue spectrometers measured oxygen saturation and hemoglobin concentration at various locations on the limb and compared with gas analyzer results. The test results demonstrated that Photonify"s tissue spectrometers were able to detect the relative changes in tissue oxygen saturation and hemoglobin concentration with a high linear correlation compared to the gas analyzer

  13. Context-aware patient guidance during blood pressure self-measurement

    DEFF Research Database (Denmark)

    Sandager, Puk; Lindahl, Camilla; Schlütter, Jacob Mørup

    2013-01-01

    The importance of accurate measurement of blood pressure in the screening and management of hypertension during pregnancy is well established. Blood pressure levels can be measured manually by healthcare staff or by using a blood pressure self-measurement device, either at home or in the clinic...... the blood pressure self-measurement process. Preliminary results indicate that such active and context-aware guidance leads to more reliable measurements by inhibiting non-adherent patient behavior...

  14. Chromium and cobalt ion concentrations in blood and serum following various types of metal-on-metal hip arthroplasties

    DEFF Research Database (Denmark)

    Jantzen, Christopher; Jørgensen, Henrik L; Duus, Benn R

    2013-01-01

    Widely different metal ion concentrations in blood and serum have been reported with metal-on-metal (MoM) implants. We reviewed the literature on blood and serum ion concentrations of chromium (Cr) and cobalt (Co) following various MoM hip arthroplasties.......Widely different metal ion concentrations in blood and serum have been reported with metal-on-metal (MoM) implants. We reviewed the literature on blood and serum ion concentrations of chromium (Cr) and cobalt (Co) following various MoM hip arthroplasties....

  15. Uranium concentration in blood samples of Southern Iraqi leukemia patients using CR-39 track detector

    International Nuclear Information System (INIS)

    Al-Hamzawi, A.A.; Al-Qadisiyah University, Qadisiyah; Jaafar, M.S.; Tawfiq, N.F.

    2014-01-01

    The simple and effective technique of fission track etch has been applied to determine trace concentration of uranium in human blood samples taken from two groups of male and female participants: leukemia patients and healthy subjects group. The blood samples of leukemia patients and healthy subjects were collected from three key southern governorates namely, Basrah, Muthanna and Dhi-Qar. These governorates were the centers of intensive military activities during the 1991 and 2003 Gulf wars, and the discarded weapons are still lying around in these regions. CR-39 track detector was used for registration of induced fission tracks. The results show that the highest recorded uranium concentration in the blood samples of leukemia patients was 4.71 ppb (female, 45 years old, from Basrah) and the minimum concentration was 1.91 ppb (male, 3 years old, from Muthanna). For healthy group, the maximum uranium concentration was 2.15 ppb (female, 55 years old, from Basrah) and the minimum concentration was 0.86 ppb (male, 5 years old, from Dhi-Qar). It has been found that the uranium concentrations in human blood samples of leukemia patients are higher than those of the healthy group. These uranium concentrations in the leukemia patients group were significantly different (P < 0.001) from those in the healthy group. (author)

  16. Relation of whole blood carboxyhemoglobin concentration to ambient carbon monoxide exposure estimated using regression.

    Science.gov (United States)

    Rudra, Carole B; Williams, Michelle A; Sheppard, Lianne; Koenig, Jane Q; Schiff, Melissa A; Frederick, Ihunnaya O; Dills, Russell

    2010-04-15

    Exposure to carbon monoxide (CO) and other ambient air pollutants is associated with adverse pregnancy outcomes. While there are several methods of estimating CO exposure, few have been evaluated against exposure biomarkers. The authors examined the relation between estimated CO exposure and blood carboxyhemoglobin concentration in 708 pregnant western Washington State women (1996-2004). Carboxyhemoglobin was measured in whole blood drawn around 13 weeks' gestation. CO exposure during the month of blood draw was estimated using a regression model containing predictor terms for year, month, street and population densities, and distance to the nearest major road. Year and month were the strongest predictors. Carboxyhemoglobin level was correlated with estimated CO exposure (rho = 0.22, 95% confidence interval (CI): 0.15, 0.29). After adjustment for covariates, each 10% increase in estimated exposure was associated with a 1.12% increase in median carboxyhemoglobin level (95% CI: 0.54, 1.69). This association remained after exclusion of 286 women who reported smoking or being exposed to secondhand smoke (rho = 0.24). In this subgroup, the median carboxyhemoglobin concentration increased 1.29% (95% CI: 0.67, 1.91) for each 10% increase in CO exposure. Monthly estimated CO exposure was moderately correlated with an exposure biomarker. These results support the validity of this regression model for estimating ambient CO exposures in this population and geographic setting.

  17. Temperature and time stability of whole blood lactate: implications for feasibility of pre-hospital measurement

    Directory of Open Access Journals (Sweden)

    Watkins Timothy R

    2011-05-01

    Full Text Available Abstract Background To determine the time and temperature stability of whole blood lactate using experimental conditions applicable to the out-of-hospital environment. Findings We performed a prospective, clinical laboratory-based study at an academic hospital. Whole blood lactate was obtained by venipuncture from five post-prandial, resting subjects. Blood was stored in lithium heparinized vacutainers in three temperature conditions: 1 room temperature (20°C, 2 wrapped in a portable, instant ice pack (0°C, or 3 wet ice (0°C. Lactate concentrations (mmol/L were measured at 0, 5, 10, 20, and 30 minutes after sampling, and compared using repeated measures analysis of variance. Mean baseline lactate among resting subjects (N = 5 was 1.24 mmol/L (95%CI: 0.49,1.98 mmol/L. After 30 minutes, lactate concentration increased, on average, by 0.08 mmol/L (95%CI: 0.02,0.13 mmol/L, 0.18 mmol/L (95%CI: 0.07,0.28 mmol/L, and 0.36 mmol/L (95%CI: 0.24,0.47 mmol/L when stored in wet ice, ice pack, and room temperature, respectively. The increase in lactate was similar in samples wrapped in portable ice pack or stored in wet ice at all time points (p > 0.05, and met criteria for equivalence at 30 minutes. However, lactate measurements from whole blood stored at room temperature were significantly greater, on average, than wet ice or portable ice pack within five and ten minutes, respectively (p Conclusions Whole blood lactate measurements using samples stored in a portable ice pack are similar to wet ice for up to 30 minutes. These conditions are applicable to the out-of-hospital environment, and should inform future studies of pre-hospital measurement of lactate.

  18. Palpatory method of measuring diastolic blood pressure

    Directory of Open Access Journals (Sweden)

    Dinesh Sahu

    2010-01-01

    Conclusion: The palpatory method would be very useful where frequent blood pressure measurement are being done manually like in wards, in busy OPD, patient on treadmill and also whenever stethoscope is not available. The blood pressure can be measured in noisy environment too.

  19. The fluctuation of blood glucose, insulin and glucagon concentrations before and after insulin therapy in type 1 diabetes

    Science.gov (United States)

    Arif, Idam; Nasir, Zulfa

    2015-09-01

    A dynamical-systems model of plasma glucose, insulin and glucagon concentrations has been developed to investigate the effects of insulin therapy on blood glucose, insulin and glucagon regulations in type 1 diabetic patients. Simulation results show that the normal regulation of blood glucose concentration depends on insulin and glucagon concentrations. On type 1 diabetic case, the role of insulin on regulating blood glucose is not optimal because of the destruction of β cells in pancreas. These β cells destructions cause hyperglycemic episode affecting the whole body metabolism. To get over this, type 1 diabetic patients need insulin therapy to control the blood glucose level. This research has been done by using rapid acting insulin (lispro), long-acting insulin (glargine) and the combination between them to know the effects of insulin therapy on blood glucose, insulin and glucagon concentrations. Simulation results show that these different types of insulin have different effects on blood glucose concentration. Insulin therapy using lispro shows better blood glucose control after consumption of meals. Glargin gives better blood glucose control between meals and during sleep. Combination between lispro and glargine shows better glycemic control for whole day blood glucose level.

  20. Red blood cell 2,3-diphosphoglycerate concentration and in vivo P50 during early critical illness.

    Science.gov (United States)

    Ibrahim, Ezz el din S; McLellan, Stuart A; Walsh, Timothy S

    2005-10-01

    To measure red blood cell 2,3-diphosphoglycerate (RBC 2,3-DPG) concentrations in early critical illness; to investigate factors associated with high or low RBC 2,3-DPG levels; to calculate in vivo P50 in patients with early critical illness; and to explore the relationship between RBC 2,3-DPG and intensive care mortality. Prospective cohort study. General medical-surgical intensive care unit (ICU) of a major Scottish teaching hospital. One-hundred eleven critically ill patients during the first 24 hrs in the ICU with no history of chronic hematologic disorders or RBC transfusion within 24 hrs and 34 age- and sex-matched healthy reference subjects. None. We measured RBC 2,3-DPG concentration, plasma biochemistry values, and arterial blood gas parameters. On average, RBC 2,3-DPG was lower among critically ill patients than controls (mean [sd], 14.1 [6.3] vs. 16.7 [3.7] mumol/g hemoglobin; p = .004) and had a wider range of values (patients, 3.2-32.5 mumol/g hemoglobin; reference group, 9.1-24.3). Regression analysis indicated a strong independent association between plasma pH and RBC 2,3-DPG (B, 32.15 [95% confidence interval, 19.07-46.22], p level was normal (3.8 kPa) but varied widely among patients (range, 2.0-5.5 kPa). RBC 2,3-DPG concentration was similar for ICU survivors and nonsurvivors. RBC 2,3-DPG concentrations vary widely among critically ill patients. Acidosis is associated with lower RBC 2,3-DPG concentrations, but anemia is not associated with a compensatory increase in RBC 2,3-DPG early in critical illness. Lower RBC 2,3-DPG concentrations during the first 24 hrs of intensive care are not associated with higher ICU mortality.

  1. Rational and timely haemostatic interventions following cardiac surgery - coagulation factor concentrates or blood bank products.

    Science.gov (United States)

    Tang, Mariann; Fenger-Eriksen, Christian; Wierup, Per; Greisen, Jacob; Ingerslev, Jørgen; Hjortdal, Vibeke; Sørensen, Benny

    2017-06-01

    Cardiac surgery may cause a serious coagulopathy leading to increased risk of bleeding and transfusion demands. Blood bank products are commonly first line haemostatic intervention, but has been associated with hazardous side effect. Coagulation factor concentrates may be a more efficient, predictable, and potentially a safer treatment, although prospective clinical trials are needed to further explore these hypotheses. This study investigated the haemostatic potential of ex vivo supplementation of coagulation factor concentrates versus blood bank products on blood samples drawn from patients undergoing cardiac surgery. 30 adults were prospectively enrolled (mean age=63.9, females=27%). Ex vivo haemostatic interventions (monotherapy or combinations) were performed in whole blood taken immediately after surgery and two hours postoperatively. Fresh-frozen plasma, platelets, cryoprecipitate, fibrinogen concentrate, prothrombin complex concentrate (PCC), and recombinant FVIIa (rFVIIa) were investigated. The haemostatic effect was evaluated using whole blood thromboelastometry parameters, as well as by thrombin generation. Immediately after surgery the compromised maximum clot firmness was corrected by monotherapy with fibrinogen or platelets or combination therapy with fibrinogen. At two hours postoperatively the coagulation profile was further deranged as illustrated by a prolonged clotting time, a reduced maximum velocity and further diminished maximum clot firmness. The thrombin lagtime was progressively prolonged and both peak thrombin and endogenous thrombin potential were compromised. No monotherapy effectively corrected all haemostatic abnormalities. The most effective combinations were: fibrinogen+rFVIIa or fibrinogen+PCC. Blood bank products were not as effective in the correction of the coagulopathy. Coagulation factor concentrates appear to provide a more optimal haemostasis profile following cardiac surgery compared to blood bank products. Copyright © 2017

  2. The concentration of glucose, insuline, thyroxine (T4), triiodthyronine (T3) and gastrine in the maternal blood, in the umbilical cord blood of their outcomes in the neonatal blood samples

    International Nuclear Information System (INIS)

    Osuch-Jaczewska, R.; Tomala, J.; Adamska, S.; Bielecka, W.; Mikulska, M.; Kalacinska, M.; Sieron, G.

    1978-01-01

    In the blood samples collected from the mothers, from the umbilical cord of their outcomes and from these neonates after 24 hours of life following estimations were performed collaterally: The concentration of insulin in 50 mothers and their fetuses and in 34 neonates, concentration of thyroxine (T 4 ) in 70 mothers and their fetuses and in 32 neonates, triiodothyronine binding coefficient (WWT 3 ) in 60 mothers and their fetuses and neonates, concentration of gastrine in 23 mothers and their fetuses and in 5 neonates. Besides that the concentration of glucose in total blood was established in 300 mothers - their fetuses and neonates. The insuline, WWT 3 and gastrine were estimated by radioimmune techniques and T 4 by radiocompetitive technique. The glucose concentration - with the aid of o-toluidine method. Basing on the results, the paper suggests that the fetus and the newborn represent independent unit in the aspect of regulation of the glucose concentration, secretion of insuline, T 3 , T 4 and gastrine, notwithstanding the possibility of transplacental passage of these hormones exists the correlation coefficients between the maternal and fetal blood concentrations of insuline, T 4 and WWT 3 were significant. The cord-blood glucose concentration exhibits a marked correlation with the maternal glicemia. Physiologic, asymptomatic hyperinsulinemia and hyperthyreosis and an increase of gastrine concentration demonstrate the presence, in the fetal and neonatal organisms, of certain compensatory-regulating mechanisms stimulating and inhibiting with feed-back properties, which guarantee the environmental homeostasis. (author)

  3. Plotting of Ethylene Glycol Blood Concentrations Using Linear Regression before and during Hemodialysis in a Case of Intoxication and Pharmacokinetic Review.

    Science.gov (United States)

    Kim, Youngho

    2015-01-01

    Introduction. As blood concentration measurement of commonly abused alcohol is readily available, the equation was proposed in previous publication to predict the change of their concentration. The change of ethylene glycol (EG) concentrations was studied in a case of intoxication to estimate required time for hemodialysis (HD) using linear regression. Case Report. A 55-year-old female with past medical history of seizure disorder, bipolar disorder, and chronic pain was admitted due to severe agitation. The patient was noted to have metabolic acidosis with elevated anion gap and acute kidney injury, which prompted blood concentration measurement of commonly abused alcohol. Her initial EG concentration was 26.45 mmol/L. Fomepizole therapy was initiated, soon followed by HD to enhance clearance. Discussion. Plotting of natural logarithm of EG concentrations over time showed that EG elimination follows first-order kinetics and predicts the change of its concentration well. Pharmacokinetic review revealed minimal elimination of EG by alcohol dehydrogenase (ADH) which could be related to genetic predisposition for ADH activity and home medications as well as presence of propylene glycol. Pharmacokinetics of EG is relatively well studied with published parameters. Consideration and application of pharmacokinetics could assist in management of EG intoxication including HD planning.

  4. Concentration of Lead, Mercury, Cadmium, Aluminum, Arsenic and Manganese in Umbilical Cord Blood of Jamaican Newborns

    Directory of Open Access Journals (Sweden)

    Mohammad H. Rahbar

    2015-04-01

    Full Text Available The objective of this study was to characterize the concentrations of lead, mercury, cadmium, aluminum, and manganese in umbilical cord blood of Jamaican newborns and to explore the possible association between concentrations of these elements and certain birth outcomes. Based on data from 100 pregnant mothers and their 100 newborns who were enrolled from Jamaica in 2011, the arithmetic mean (standard deviation concentrations of cord blood lead, mercury, aluminum, and manganese were 0.8 (1.3 μg/dL, 4.4 (2.4 μg/L, 10.9 (9.2 μg/L, and 43.7 (17.7 μg/L, respectively. In univariable General Linear Models, the geometric mean cord blood aluminum concentration was higher for children whose mothers had completed their education up to high school compared to those whose mothers had any education beyond high school (12.2 μg/L vs. 6.4 μg/L; p < 0.01. After controlling for maternal education level and socio-economic status (through ownership of a family car, the cord blood lead concentration was significantly associated with head circumference (adjusted p < 0.01. Our results not only provide levels of arsenic and the aforementioned metals in cord blood that could serve as a reference for the Jamaican population, but also replicate previously reported significant associations between cord blood lead concentrations and head circumference at birth in other populations.

  5. Concentration of Lead, Mercury, Cadmium, Aluminum, Arsenic and Manganese in Umbilical Cord Blood of Jamaican Newborns

    Science.gov (United States)

    Rahbar, Mohammad H.; Samms-Vaughan, Maureen; Dickerson, Aisha S.; Hessabi, Manouchehr; Bressler, Jan; Coore Desai, Charlene; Shakespeare-Pellington, Sydonnie; Reece, Jody-Ann; Morgan, Renee; Loveland, Katherine A.; Grove, Megan L.; Boerwinkle, Eric

    2015-01-01

    The objective of this study was to characterize the concentrations of lead, mercury, cadmium, aluminum, and manganese in umbilical cord blood of Jamaican newborns and to explore the possible association between concentrations of these elements and certain birth outcomes. Based on data from 100 pregnant mothers and their 100 newborns who were enrolled from Jamaica in 2011, the arithmetic mean (standard deviation) concentrations of cord blood lead, mercury, aluminum, and manganese were 0.8 (1.3 μg/dL), 4.4 (2.4 μg/L), 10.9 (9.2 μg/L), and 43.7 (17.7 μg/L), respectively. In univariable General Linear Models, the geometric mean cord blood aluminum concentration was higher for children whose mothers had completed their education up to high school compared to those whose mothers had any education beyond high school (12.2 μg/L vs. 6.4 μg/L; p < 0.01). After controlling for maternal education level and socio-economic status (through ownership of a family car), the cord blood lead concentration was significantly associated with head circumference (adjusted p < 0.01). Our results not only provide levels of arsenic and the aforementioned metals in cord blood that could serve as a reference for the Jamaican population, but also replicate previously reported significant associations between cord blood lead concentrations and head circumference at birth in other populations. PMID:25915835

  6. Novel idea to monitor and measure blood hemoglobin noninvasively ...

    African Journals Online (AJOL)

    Measuring blood hematocrit noninvasively is reviewed in this paper. Although there is an inclination to measure the hematocrit by determining the bioelectrical impedance of the blood, in vitro experimental methods still remain practically inapplicable. The blood sample size is determined when blood samples are examined.

  7. Blood pressure measurement in obese patients: comparison between upper arm and forearm measurements.

    Science.gov (United States)

    Pierin, Angela M G; Alavarce, Débora C; Gusmão, Josiane L; Halpern, Alfredo; Mion, Décio

    2004-06-01

    It is well known that blood pressure measurement with a standard 12-13 cm wide cuff is erroneous for large arms. To compare arm blood pressure measurements with an appropriate cuff and forearm blood pressure measurements (BPM) with a standard cuff, and both measurements by the Photopletismography (Finapres) method. One hundred and twenty-nine obese patients were studied (body mass index=40+/-7 kg/m2). The patients had three arm BPM taken by an automatic oscillometric device using an appropriate cuff and three forearm BPM with a standard cuff in the sitting position after a five-minute rest. Data were analysed by the analysis of variance. The correction values were obtained by the linear regression test. Systolic and diastolic arm BPM with an appropriate cuff were significantly lower (pforearm BPM with a standard cuff. The measurements obtained by Finapres were significantly lower (pforearm systolic and diastolic blood pressures and upper arm diastolic blood pressure. The equation to correct BPM in forearm in obese patients with arm circumference between 32-44 cm was: systolic BPM=33.2+/-0.68 x systolic forearm BPM, and diastolic BPM=25.2+0.59 x forearm diastolic BPM. This study showed that forearm blood pressure measurement overestimates the values of arm blood pressure measurement. In addition, it is possible to correct forearm BPM with an equation.

  8. Differences in iron concentration in whole blood of animal models using NAA

    International Nuclear Information System (INIS)

    Bahovschi, V; Zamboni, C B; Silva, L F F Lopes; Metairon, S; Medeiros, I M M A

    2015-01-01

    In this study Neutron Activation Analysis technique (NAA) was applied to determine Fe concentration in whole blood samples of several animal models such as: mice (Mus musculus), Golden Hamster (Mesocricetus auratus), Wistar rats, Albinic Rabbits of New Zealand, Golden Retriever dogs and Crioulabreed horses. These results were compared with human whole blood estimation to check their similarities. (paper)

  9. Differences in iron concentration in whole blood of animal models using NAA

    Science.gov (United States)

    Bahovschi, V.; Zamboni, C. B.; Lopes Silva, L. F. F.; Metairon, S.; Medeiros, I. M. M. A.

    2015-07-01

    In this study Neutron Activation Analysis technique (NAA) was applied to determine Fe concentration in whole blood samples of several animal models such as: mice (Mus musculus), Golden Hamster (Mesocricetus auratus), Wistar rats, Albinic Rabbits of New Zealand, Golden Retriever dogs and Crioulabreed horses. These results were compared with human whole blood estimation to check their similarities.

  10. A simple and rapid method for measurement of 10B-para-boronophenylalanine in the blood for boron neutron capture therapy using fluorescence spectrophotometry

    International Nuclear Information System (INIS)

    Kashino, Genro; Fukutani, Satoshi; Suzuki, Minoru

    2009-01-01

    10 B deriving from 10 B-para-boronophenylalanine (BPA) and 10 B-borocaptate sodium (BSH) have been detected in blood samples of patients undergoing boron neutron capture therapy (BNCT) using prompt gamma ray spectrometer or Inductively Coupled Plasma (ICP) method, respectively. However, the concentration of each compound cannot be ascertained because boron atoms in both molecules are the target in these assays. Here, we propose a simple and rapid method to measure only BPA by detecting fluorescence based on the characteristics of phenylalanine. 10 B concentrations of blood samples from human or mice were estimated by the fluorescence intensities at 275 nm of a BPA excited by light of wavelength 257 nm using a fluorescence spectrophotometer. The relationship between fluorescence to increased BPA concentration showed a positive linear correlation. Moreover, we established an adequate condition for BPA measurement in blood samples containing BPA, and the estimated 10 B concentrations of blood samples derived from BPA treated mice were similar between the values obtained by our method and those by ICP method. This new assay will be useful to estimate BPA concentration in blood samples obtained from patients undergoing BNCT especially in a combination use of BSH and BPA. (author)

  11. Impact of Ficoll density gradient centrifugation on major and trace element concentrations in erythrocytes and blood plasma.

    Science.gov (United States)

    Lu, Ying; Ahmed, Sultan; Harari, Florencia; Vahter, Marie

    2015-01-01

    Ficoll density gradient centrifugation is widely used to separate cellular components of human blood. We evaluated the suitability to use erythrocytes and blood plasma obtained from Ficoll centrifugation for assessment of elemental concentrations. We determined 22 elements (from Li to U) in erythrocytes and blood plasma separated by direct or Ficoll density gradient centrifugation, using inductively coupled plasma mass spectrometry. Compared with erythrocytes and blood plasma separated by direct centrifugation, those separated by Ficoll had highly elevated iodine and Ba concentration, due to the contamination from the Ficoll-Paque medium, and about twice as high concentrations of Sr and Mo in erythrocytes. On the other hand, the concentrations of Ca in erythrocytes and plasma were markedly reduced by the Ficoll separation, to some extent also Li, Co, Cu, and U. The reduced concentrations were probably due to EDTA, a chelator present in the Ficoll medium. Arsenic concentrations seemed to be lowered by Ficoll, probably in a species-specific manner. The concentrations of Mg, P, S, K, Fe, Zn, Se, Rb, and Cs were not affected in the erythrocytes, but decreased in plasma. Concentrations of Mn, Cd, and Pb were not affected in erythrocytes, but in plasma affected by EDTA and/or pre-analytical contamination. Ficoll separation changed the concentrations of Li, Ca, Co, Cu, As, Mo, I, Ba, and U in erythrocytes and blood plasma, Sr in erythrocytes, and Mg, P, S, K, Fe, Zn, Se, Rb and Cs in blood plasma, to an extent that will invalidate evaluation of deficiencies or excess intakes. Copyright © 2014 Elsevier GmbH. All rights reserved.

  12. Influence of Estimated Training Status on Anti and Pro-Oxidant Activity, Nitrite Concentration, and Blood Pressure in Middle-Aged and Older Women.

    Science.gov (United States)

    Jacomini, André M; Dias, Danielle da Silva; Brito, Janaina de Oliveira; da Silva, Roberta F; Monteiro, Henrique L; Llesuy, Susana; De Angelis, Kátia; Amaral, Sandra L; Zago, Anderson S

    2017-01-01

    The purpose of this study was to compare the association between anti and pro-oxidant activity, nitrite concentration, and blood pressure (BP) in middle-aged and older women with different levels of estimated training status (TS). The sample consisted of 155 females (50-84 years) who were submitted to a physical examination to evaluate estimated TS through the "Functional Fitness Battery Test," BP measurements, and plasma blood samples to evaluate pro-oxidant and antioxidant activity and nitrite concentrations. Participants were separated by age into a middle-aged group (<65 years) and an older (≥65 years) group and then subdivided in each group according to TS. Blood biochemistry was similar between groups. On the other hand, protein oxidation was lower in participants with higher TS, independent of age. Older females with higher TS presented higher nitrite concentrations, lower lipoperoxidation, and lower values of BP compared with those with lower TS. Lower GPx activity was observed in participants with higher TS compared with middle-aged with lower TS. Thus, our results suggest that good levels of TS may be associated with lower oxidative stress and higher nitrite concentration and may contribute to maintain normal or reduced blood pressure values.

  13. Measurement of regional cerebral blood flow by intravenous administation of 133 xenon

    International Nuclear Information System (INIS)

    Ryding, E.

    1986-01-01

    Reviewing the background and the theory for rCFB measurements the following conditions are established for the use of flow measurement with 133-Xenon as a reliable indicator for indirect measurements of cerebral functional activity. 1. There is a strict coupling between rCBF and regional metabolism. This condition can only be considered to be fulfilled in the normal non-anoxic bran tissue. 2. There is a close correlation between the tissue and the venous concentration of 133-Xenin which can be reliably approximated by the blood-brain partition coefficient. This condition can be considered to be fullfilled in the normal flow range, but not in pathological conditions such as cerebrovascular occlusions. 3. Intercompartment diffusion of 133-Xenon has no significant effect upon the measurement of rCBF values. This condition appear to share its limitations for fulfilement with condition 2. 4. There is no significant contamination by the extracerebral flow components at IH or IV rCBF measurements. 5. There is a negligible 'look through' effect from surrounding areas to region with focal high or low blood flow. (U.W.)

  14. The measurement of limb blood flow using technetium-labelled red blood cells

    International Nuclear Information System (INIS)

    Parkin, A; Robinson, P.J.; Wiggins, P.A.; Leveson, S.H.; Salter, M.C.P.; Matthews, I.F.; Ware, F.M.

    1986-01-01

    A method for measuring blood flow below the knee during reactive hyperaemia induced by 3 min of arterial occlusion has been developed. Subjects are positioned with lower limbs within the field of view of a gamma camera and pneumatic cuffs are placed below the knees to isolate the blood and induce a hyperaemic response. The remaining blood pool is labelled with 99 Tcsup(m)-labelled red cells. Blood flows have been derived from the initial gradients of time-activity curves and from equilibrium blood sampling. The technique has been validated using a tissue-equivalent leg phantom and peristaltic pump. The method has been applied to a small group of patients with peripheral vascular disease and to normal controls. The mean value (+-SD) of limb perfusion for normal controls was found to be 16.4+-3.0 ml/100 ml/min and for patients with intermittent claudication was 5.1+-2.6 ml/100 ml/min. Flow measurements are found to correlate with clinical findings and with symptoms. Reproducibility (established by repeated measurements) is high. The method is well tolerated even by patients suffering from rest pain. (author)

  15. Arterialized and venous blood lactate concentration difference during different exercise intensities

    Directory of Open Access Journals (Sweden)

    Leandro C. Felippe

    2017-06-01

    Conclusion: These results suggest a delayed lactate appearance in the venous blood, which is accentuated at higher exercise intensities. The lactate measured in arterialized and venous blood is interchangeable only when blood samples are collected at least 10 minutes after the exercise starts.

  16. Blood cadmium concentrations and environmental exposure sources in newcomer South and East Asian women in the Greater Toronto Area, Canada

    International Nuclear Information System (INIS)

    Wiseman, C.L.S.; Parnia, A.; Chakravartty, D.; Archbold, J.; Zawar, N.; Copes, R.; Cole, D.C.

    2017-01-01

    Background: Immigrant women are often identified as being particularly vulnerable to environmental exposures and health effects. The availability of biomonitoring data on newcomers is limited, thus, presenting a challenge to public health practitioners in the identification of priorities for intervention. Objectives: In fulfillment of data needs, the purpose of this study was to characterize blood concentrations of cadmium (Cd) among newcomer women of reproductive age (19–45 years of age) living in the Greater Toronto Area (GTA), Canada and to assess potential sources of environmental exposures. Methods: A community-based model, engaging peer researchers from the communities of interest, was used for recruitment and follow-up purposes. Blood samples were taken from a total of 211 newcomer women from South and East Asia, representing primary, regional origins of immigrants to the GTA, and environmental exposure sources were assessed via telephone survey. Metal concentrations were measured in blood samples (diluted with 0.5% (v/v) ammonium hydroxide and 0.1% (v/v) octylphenol ethoxylate) using a quadrupole ICP-MS. Survey questions addressed a wide range of environmental exposure sources, including dietary and smoking patterns and use of nutritional supplements, herbal products and cosmetics. Results: A geometric mean (GM) blood Cd concentration of 0.39 µg/L (SD:±2.07 µg/L) was determined for study participants (min/max: <0.045 µg /L (LOD)/2.36 µg/L). Several variables including low educational attainment (Relative Ratio (RR) (adjusted)=1.50; 95% CI 1.17–1.91), milk consumption (RR (adjusted)=0.86; 95% CI 0.76–0.97), and use of zinc supplements (RR (adjusted)=0.76; 95% CI 0.64–0.95) were observed to be significantly associated with blood Cd concentrations in the adjusted regression model. The variable domains socioeconomic status (R 2 adj =0.11) and country of origin (R 2 adj =0.236) were the strongest predictors of blood Cd. Conclusion: Blood Cd

  17. Blood cadmium concentrations and environmental exposure sources in newcomer South and East Asian women in the Greater Toronto Area, Canada

    Energy Technology Data Exchange (ETDEWEB)

    Wiseman, C.L.S., E-mail: clare.wiseman@utoronto.ca [School of the Environment, University of Toronto (Canada); Dalla Lana School of Public Health, University of Toronto (Canada); Parnia, A.; Chakravartty, D. [Dalla Lana School of Public Health, University of Toronto (Canada); Archbold, J. [Toronto Public Health (Canada); Zawar, N. [Dalla Lana School of Public Health, University of Toronto (Canada); Copes, R. [Dalla Lana School of Public Health, University of Toronto (Canada); Public Health Ontario (Canada); Cole, D.C. [School of the Environment, University of Toronto (Canada); Dalla Lana School of Public Health, University of Toronto (Canada)

    2017-04-15

    Background: Immigrant women are often identified as being particularly vulnerable to environmental exposures and health effects. The availability of biomonitoring data on newcomers is limited, thus, presenting a challenge to public health practitioners in the identification of priorities for intervention. Objectives: In fulfillment of data needs, the purpose of this study was to characterize blood concentrations of cadmium (Cd) among newcomer women of reproductive age (19–45 years of age) living in the Greater Toronto Area (GTA), Canada and to assess potential sources of environmental exposures. Methods: A community-based model, engaging peer researchers from the communities of interest, was used for recruitment and follow-up purposes. Blood samples were taken from a total of 211 newcomer women from South and East Asia, representing primary, regional origins of immigrants to the GTA, and environmental exposure sources were assessed via telephone survey. Metal concentrations were measured in blood samples (diluted with 0.5% (v/v) ammonium hydroxide and 0.1% (v/v) octylphenol ethoxylate) using a quadrupole ICP-MS. Survey questions addressed a wide range of environmental exposure sources, including dietary and smoking patterns and use of nutritional supplements, herbal products and cosmetics. Results: A geometric mean (GM) blood Cd concentration of 0.39 µg/L (SD:±2.07 µg/L) was determined for study participants (min/max: <0.045 µg /L (LOD)/2.36 µg/L). Several variables including low educational attainment (Relative Ratio (RR) (adjusted)=1.50; 95% CI 1.17–1.91), milk consumption (RR (adjusted)=0.86; 95% CI 0.76–0.97), and use of zinc supplements (RR (adjusted)=0.76; 95% CI 0.64–0.95) were observed to be significantly associated with blood Cd concentrations in the adjusted regression model. The variable domains socioeconomic status (R{sup 2}{sub adj}=0.11) and country of origin (R{sup 2}{sub adj}=0.236) were the strongest predictors of blood Cd. Conclusion

  18. Blood pressure measurement: one arm or both arm?

    Science.gov (United States)

    Kulkarni, Prasad K; Shekhar, Susheela; Reddy, B N; Nirmala, B C

    2011-09-01

    Guidelines for measuring blood pressure includes measurement of blood pressure on both arms but it is often ignored. Our case report aims at highlighting the need follow the guidelines. A 60 year old 59 kg weighing male asymptomatic patient without any comobidities was posted for bilateral inguinal hernia repair. The interarm blood pressure difference was discovered incidentally during his preanaesthetic evalution. On further evaluation patient was found to be having subclavian stenosis on left side which was asymptomatic. Intraoperative and post operative period was uneventful. Blood pressure measurement should be done in accordance with the stipulated guidelines. Inter arm blood pressure difference should be noted in all patients as not only for diagnosis and treatment of hypertension but also as a tool to diagnose asymptomatic peripheral vascular disesase.

  19. The need for blood alcohol concentration (BAC) legislation in Nigeria

    African Journals Online (AJOL)

    The pharmacology, clinical and sports implications of indulgence in alcohol and the debate on its legal status are highlighted in this article. The information presented could offer both clinical and safety benefits to psychomotor tasks executors and road safety professionals. Keywords: Blood alcohol concentration (BAC), ...

  20. Postmortem Femoral Blood Reference Concentrations of Aripiprazole, Chlorprothixene, and Quetiapine

    DEFF Research Database (Denmark)

    Skov, Louise; Johansen, Sys Stybe; Linnet, Kristian

    2015-01-01

    no or only limited postmortem redistribution for aripiprazole, chlorprothixene with metabolite, and quetiapine in these cases. One fatality caused by chlorprothixene with a blood level of 0.90 mg/kg was recorded, and in six cases chlorprothixene was judged to be contributing to death with concentrations 0...

  1. Analysis of Blood Concentrations of Zinc, Germanium, and Lead and Relevant Environmental Factors in a Population Sample from Shandong Province, China

    Directory of Open Access Journals (Sweden)

    Long Li

    2017-02-01

    Full Text Available Trace elements, including zinc (Zn and germanium (Ge, are essential for health; deficiency or excess levels of trace elements results is harmful. As a result of industrial and agricultural production, Pb widely exists in people’s living environment. It is absorbed mainly through the respiratory and digestive tracts, producing systemic harm. Reference values for a normal, healthy population are necessary for health assessment, prevention and treatment of related diseases, and evaluation of occupational exposures. Reference ranges for the Chinese population have not been established. From March 2009 to February 2010; we collected data and blood samples (n = 1302 from residents aged 6–60 years living in Shandong Province, China. We measured blood concentrations of Zn, Ge, and Pb using inductively coupled plasma mass spectrometry to determine reference ranges. Results were stratified by factors likely to affect the concentrations of these trace elements: sex, use of cosmetics or hair dye, age, alcohol intake, smoking habits, and consumption of fried food. The overall geometric mean (GM concentrations (95% confidence interval were 3.14 (3.08–3.20 mg/L for Zn, 19.9 (19.3–20.6 μg/L for Ge, and 24.1 (23.2–25.1 μg/L for Pb. Blood Zn concentrations were higher in women than in men (p < 0.001, while the opposite was found for Pb (p < 0.001 and sex did not influence Ge (p = 0.095. Alcohol use was associated with higher blood concentrations of Zn (p = 0.002, Ge (p = 0.002, and Pb (p = 0.001. The GM concentration of Zn was highest in 20–30-year-olds (p < 0.001, while Pb concentrations were highest in 12–16-year-olds (p < 0.001. Use of hair dye was associated with lower blood concentrations of Ge (p < 0.05. GM blood concentrations of Pb differed significantly between those who consumed fried foods 1–2 times/month (18.7 μg/L, 1–2 times/week (20.9 μg/L, and every day (28.5 μg/L; p < 0.001. Blood Pb concentrations were higher in subjects

  2. Blood alcohol concentration testing and reporting by the states : traffic tech.

    Science.gov (United States)

    2012-08-01

    Accurate and complete data on blood alcohol concentration : (BAC) levels for drivers in fatal crashes are critical in monitoring : alcohol-impaired-driving rates across the country, developing : alcohol-impaired-driving programs, and evaluating : the...

  3. Monthly variation in faeces:blood concentration ratio of persistent organic pollutants over the first year of life: a case study of one infant

    International Nuclear Information System (INIS)

    Chen, Yiqin; McLachlan, Michael S.; Kaserzon, Sarit; Wang, Xianyu; Weijs, Liesbeth; Gallen, Michael; Toms, Leisa-Maree L.; Li, Yan; Aylward, Lesa L.; Sly, Peter D.; Mueller, Jochen F.

    2016-01-01

    Previous studies have found that the concentrations of a range of persistent organic pollutants (POPs) in faeces is linearly proportional to the POP concentrations in blood of human adults irrespective of age and gender. In order to investigate the correlation between POP concentrations in faeces and blood in infants, the monthly variation of POP concentrations in faeces over the first year of life of one infant was investigated in this study and compared to modelled blood concentrations. Faecal samples were collected from one male infant daily. The samples were pooled by month and analysed for three selected POPs (2,2 ′ ,4,4 ′ ,5,5 ′ -Hexachlorobiphenyl (PCB153), p,p′-dichlorodiphenyldichloroethylene (p,p′-DDE) and 2,2 ′ ,4,4′-tetrabromodiphenyl ether (BDE47)). The POP concentrations in faecal samples increased for the first four months by a factor of 2.9, 4.9 and 1.4 for PCB153, BDE47, and p,p′-DDE, respectively. The faecal concentrations of all POPs decreased rapidly following the introduction of formula and solid food to the diet and subsequent weaning of the infant. Further, a one-compartment model was developed to estimate the daily POP concentrations in the blood of the infant. The POP concentrations in blood were predicted to vary much less over the first year than those observed in faeces. The faeces:blood concentration ratio of selected POPs (K fb ) differed significantly (P<0.0001) between the period before and after weaning, and observed changes in K fb are far greater than the uncertainty in the estimated K fb . A more stable K fb after weaning indicates the possibility of applying the stable K fb values for non-invasive assessment of internal exposure in infants after weaning. The intra-individual variation in K fb in infants is worthy of further investigation. - Highlights: • Measured POPs concentrations in faecal samples decreased rapidly following weaning. • Ratio of faecal:blood concentrations (K fb ) changed over the first

  4. Estimation of chloroform inhalation dose by other routes based on the relationship of area under the blood concentration-time curve (AUC)-inhalation dose to chloroform distribution in the blood of rats.

    Science.gov (United States)

    Take, Makoto; Takeuchi, Tetsuya; Haresaku, Mitsuru; Matsumoto, Michiharu; Nagano, Kasuke; Yamamoto, Seigo; Takamura-Enya, Takeji; Fukushima, Shoji

    2014-01-01

    The present study investigated the time-course changes of concentration of chloroform (CHCl3) in the blood during and after exposure of male rats to CHCl3 by inhalation. Increasing the dose of CHCl3 in the inhalation exposed groups caused a commensurate increase in the concentration of CHCl3 in the blood and the area under the blood concentration-time curve (AUC). There was good correlation (r = 0.988) between the inhalation dose and the AUC/kg body weight. Based on the AUC/kg body weight-inhalation dose curve and the AUC/kg body weight after oral administration, inhalation equivalent doses of orally administered CHCl3 were calculated. Calculation of inhalation equivalent doses allows the body burden due to CHCl3 by inhalation exposure and oral exposure to be directly compared. This type of comparison facilitates risk assessment in humans exposed to CHCl3 by different routes. Our results indicate that when calculating inhalation equivalent doses of CHCl3, it is critical to include the AUC from the exposure period in addition to the AUC after the end of the exposure period. Thus, studies which measure the concentration of volatile organic compounds in the blood during the inhalation exposure period are crucial. The data reported here makes an important contribution to the physiologically based pharmacokinetic (PBPK) database of CHCl3 in rodents.

  5. Geographic and temporal patterns of variation in total mercury concentrations in blood of harlequin ducks and blue mussels from Alaska.

    Science.gov (United States)

    Savoy, Lucas; Flint, Paul; Zwiefelhofer, Denny; Brant, Heather; Perkins, Christopher; Taylor, Robert; Lane, Oksana; Hall, Jeff; Evers, David; Schamber, Jason

    2017-04-15

    We compared total mercury (Hg) concentrations in whole blood of harlequin ducks (Histrionicus histrionicus) sampled within and among two geographically distinct locations and across three years in southwest Alaska. Blue mussels were collected to assess correlation between Hg concentrations in locally available forage and birds. Mercury concentrations in harlequin duck blood were significantly higher at Unalaska Island (0.31±0.19 mean±SD, μg/g blood) than Kodiak Island (0.04±0.02 mean±SD, μg/g blood). We found no evidence for annual variation in blood Hg concentration between years at Unalaska Island. However, blood Hg concentration did vary among specific sampling locations (i.e., bays) at Unalaska Island. Findings from this study demonstrate harlequin ducks are exposed to environmental sources of Hg, and whole blood Hg concentrations are associated with their local food source. Copyright © 2017 Elsevier Ltd. All rights reserved.

  6. Reduced blood flow increases the in vivo ammonium ion concentration in the RIF-1 tumor

    International Nuclear Information System (INIS)

    Constantinidis, Ioannis; Gamcsik, Michael P.

    1995-01-01

    Purpose: Previous studies from our laboratory have suggested that pooling of ammonium in tumor tissues may be caused by its inefficient removal due to the poor vasculature commonly found in tumors. The purpose of these experiments was to validate the relationship between tumor ammonium ion concentration and tumor blood flow, and to determine whether large concentrations of ammonium ion detected by Nuclear Magnetic Resonance (NMR) spectroscopy are either produced within the tumor or simply imported into the tumor through the blood stream. Methods and Materials: To test this hypothesis, we reduced blood flow in subcutaneously grown Radiation Induced Fibrosarcoma-1 (RIF-1) tumors, either by creating partial ischemia with a bolus injection of hydralazine or by occlusion with surgical sutures. 14 N and 31 P NMR spectroscopy were used to detect the presence of ammonium, and to assess the bioenergetic status of the tumors, respectively. Results: A correlation between ammonium ion concentration and (PCr(P i )) ratio was established for untreated tumors. An increase in the in vivo tumor ammonium ion concentration was observed for every tumor that experienced a reduction in blood flow caused by either hydralazine injection or suture ligation. Changes in ammonium ion concentration paralleled changes in the bioenergetics of hydralazine-treated tumors. Conclusion: Our results support the hypothesis that a reduction in tumor blood flow is responsible for the accumulation of ammonium in tumors, and that detected ammonium originated from within the tumor

  7. THE EFFECT OF BLOOD AND MILK SERUM ZINC CONCENTRATION ON MILK SOMATIC CELL COUNT IN DAIRY COWS

    Directory of Open Access Journals (Sweden)

    Ivana Davidov

    2016-11-01

    Full Text Available The objective of this study was to evaluate the effect of blood and milk zinc concentration on somatic cell count and occurrence of subclinical mastitis cases. The study was performed on thirty Holstein cows approximate same body weight, ages 3 to 5 years, with equally milk production. Blood samples were taken after the morning milking from the caudal vein and milk from all four quarters was taken before morning milking. All samples of blood and milk were taken to determined zinc, using inductively coupled plasma mass spectrometry. 37.67% (11/30 cows have blood serum zinc concentration below 7µmol/l, and 63.33% or 19/30 cows have blood serum zinc concentration higher then 13µmol/l. Also 30% (9/30 cows have somatic cell count lower then 400.000/ml which indicate absence of subclinical mastitis, but 70% (21/30 cows have somatic cell count higher then 400.000/ml which indicate subclinical mastitis. Results indicate that cows with level of zinc in blood serum higher then 13 µmol/l have lower somatic cell count. Cows with lower zinc blood serum concentration then 7 µmol/l have high somatic cell count and high incidence of subclinical mastitis. According to results in this research there is no significant effect of milk serum zinc concentration on somatic cell count in dairy cows.

  8. Suspected hypoglycaemia in out patient practice: accuracy of dried blood spot analysis.

    Science.gov (United States)

    Parker, D R; Bargiota, A; Cowan, F J; Corrall, R J

    1997-12-01

    The assay of dried blood spots on filter paper to determine blood glucose concentration has been used to detect hypoglycaemia in out patients. We assessed the accuracy of this approach in assaying blood glucose concentrations in the hypoglycaemic range. Volunteers were rendered hypoglycaemic by intravenous infusion of insulin. The glucose concentration in simultaneously taken blood samples was measured either fresh or after drying on filter paper. Twenty-four healthy young volunteers and 9 patients with insulin-dependent diabetes were studied. Plasma glucose concentrations were measured using a standard auto analyser glucose oxidase method. Whole blood taken simultaneously was placed on prepared filter paper and allowed to dry; glucose concentration was then measured using a well-established technique. A correction factor was applied to convert the glucose concentration of plasma to that of whole blood. The relationship between glucose concentrations measured by the two methods was determined by regression coefficient. In the unequivocally hypoglycaemic range (plasma dried blood spot glucose concentrations significantly correlated with standard plasma glucose concentrations (r = 0.81; P dried blood spot method had a sensitivity of 91%. In the range designated probable hypoglycaemia (plasma dried blood spot method was 100% in both ranges. Measurement of glucose concentrations in dried blood spots is specific and sensitive in the hypoglycaemic range. The present study indicates that hypoglycaemia may be excluded or confirmed respectively when levels in excess of 3.7 or below 2.8 mmol/l are found in uncorrected dried blood spot analysis.

  9. An evaluation of the use of blood metabolite concentrations as ...

    African Journals Online (AJOL)

    The aim of this study was to determine whether blood metabolite concentrations in free-ranging indigenous goats are sensitive to expected variations in nutrient supply, and whether they could be used to evaluate different kidding seasons at two locations subject to similar seasonal variations in terms of nutrient supply.

  10. A Western Diet Pattern Is Associated with Higher Concentrations of Blood and Bone Lead among Middle-Aged and Elderly Men.

    Science.gov (United States)

    Wang, Xin; Ding, Ning; Tucker, Katherine L; Weisskopf, Marc G; Sparrow, David; Hu, Howard; Park, Sung Kyun

    2017-07-01

    Background: Little is known about the effects of overall dietary pattern on lead concentration. Objective: We examined the association of overall dietary patterns, derived from a semiquantitative food frequency questionnaire, with bone and blood lead concentrations. Methods: These longitudinal analyses included mostly non-Hispanic white, middle-aged-to-elderly men from the Veterans Affairs Normative Aging Study. Long-term lead exposures were measured as tibia and patella lead concentrations by using K-shell-X-ray fluorescence. Short-term lead exposures were measured as blood lead concentrations by using graphite furnace atomic absorption spectroscopy. Dietary pattern scores were derived by using factor analysis. Linear mixed-effects models were utilized to predict blood lead concentrations among 983 men, aged 44-92 y at baseline, with a total of 3273 observations (during 1987-2008). We constructed linear regression models to determine the relations between dietary patterns and bone lead concentrations among 649 participants with an age range of 49-93 y. Results: Two major dietary patterns were identified: a prudent dietary pattern, characterized by high intakes of fruit, legumes, vegetables, whole grains, poultry, and seafood; and a Western dietary pattern, characterized by high intakes of processed meat, red meat, refined grains, high-fat dairy products, French fries, butter, and eggs. After adjusting for age, smoking status, body mass index, total energy intake, education, occupation, neighborhood-based education and income level, men in the highest tertile of the Western pattern score (compared with the lowest) had 0.91 μg/dL (95% CI: 0.41, 1.42 μg/dL) higher blood lead, 5.96 μg/g (95% CI: 1.76, 10.16 μg/g) higher patella lead, and 3.83 μg/g (95% CI: 0.97, 6.70 μg/g) higher tibia lead. No significant association was detected with the prudent dietary pattern in the adjusted model. Conclusions: These findings suggest that the Western diet is associated with

  11. Glucose concentration in capillary blood of dairy cows obtained by a minimally invasive lancet technique and determined with three different hand-held devices

    OpenAIRE

    Mair, B.; Drillich, M.; Klein-J?bstl, D.; Kanz, P.; Borchardt, S.; Meyer, L.; Schwendenwein, I.; Iwersen, M.

    2016-01-01

    Background Dairy cows have a massive demand for glucose at the onset of lactation. A poor adaption to this period leads to an excessive negative energy balance with an increased risk for ketosis and impaired animal health and production. Besides the measurement of ketones, analysing the glucose concentration in blood is reported as helpful instrument for diagnosis and differentiation of ketosis. Monitoring metabolic parameters requires multiple blood sampling. In other species, new blood samp...

  12. Study of measurement of the alcohol biomarker phosphatidylethanol (PEth) in dried blood spot (DBS) samples and application of a volumetric DBS device.

    Science.gov (United States)

    Beck, Olof; Kenan Modén, Naama; Seferaj, Sabina; Lenk, Gabriel; Helander, Anders

    2018-04-01

    Phosphatidylethanol (PEth) is a group of phospholipids formed in cell membranes following alcohol consumption. PEth measurement in whole blood samples is established as a specific alcohol biomarker with clinical and medico-legal applications. This study further evaluated the usefulness of dried blood spot (DBS) samples collected on filter paper for PEth measurement. Specimens used were surplus volumes of venous whole blood sent for routine LC-MS/MS quantification of PEth 16:0/18:1, the major PEth homolog. DBS samples were prepared by pipetting blood on Whatman 903 Protein Saver Cards and onto a volumetric DBS device (Capitainer). The imprecision (CV) of the DBS sample amount based on area and weight measurements of spot punches were 23-28%. Investigation of the relationship between blood hematocrit and PEth concentration yielded a linear, positive correlation, and at around 1.0-1.5μmol/L PEth 16:0/18:1, the PEth concentration increased by ~0.1μmol/L for every 5% increase in hematocrit. There was a close agreement between the PEth concentrations obtained with whole blood samples and the corresponding results using Whatman 903 (PEth DBS =1.026 PEth WB +0.013) and volumetric device (PEth DBS =1.045 PEth WB +0.016) DBS samples. The CV of PEth quantification in DBS samples at concentrations≥0.05μmol/L were ≤15%. The present results further confirmed the usefulness of DBS samples for PEth measurement. Copyright © 2018 Elsevier B.V. All rights reserved.

  13. Measurement of bone blood flow in sheep

    International Nuclear Information System (INIS)

    Rosenthal, M.S.; Lehner, C.E.; Pearson, D.W.; Kanikula, T.; Adler, G.; Venci, R.; Lanphier, E.H.; DeLuca, P.M. Jr.

    1984-01-01

    Bone blood flow in sheep tibia has been estimated via the measurement of the perfusion limited clearance of 41 Ar from the bone mineral matrix following fast neutron activation of 44 Ca. Tibia blood flows were estimated for the intact sheep, and after the installation of an intramedullary pressure tap to elevate bone marrow pressure by saline infusion. The results indicate that normal blood flow in the tibia is in the range of 1.1 to 3.7 ml/100ml-min in the intact animal and at normal marrow pressure. With an elevated intramedullary pressure of approximately 100 mmHg, the bone blood flow measured varied around 0.5 to 1.1 ml/100ml-min. 12 refs., 5 figs., 1 tab

  14. Blood parameters and apparent digestibility of concentrate with rice oil for horses

    Directory of Open Access Journals (Sweden)

    Helio Alberto Cumani Garcia

    2013-10-01

    Full Text Available Apparent digestibility coefficients and serum parameters were measured to evaluate the effect of supplementing feed concentrates with rice bran oil in horses. Twelve horses (6 males and 6 females with a mean age of 18 ± 4 months old and mean live weight of 306 ± 22.6 kg were used. Treatments consisted of increasing rice bran oil concentrate levels of 0, 3.5, 7.0, 10.5, 14.0 and 17.5%, considering a daily intake of 2.25% live weight on a dry matter basis. A dietary effect of supplementation on the apparent digestibility of gross energy (y = 64.55 - 0.58x was observed (P0.05. Supplementation did not affect serum glucose levels (P>0.05, but cholesterol was affected (P0.05. A dietary effect on the triglyceride (y = 15.73 - 0.96x + 0.0524x² and HDL (high-density lipoprotein (y = 45.24 + 1.0499x parameters was observed (P<0.01. While the use of rice bran oil does affect blood parameters associated with lipid metabolism, rice bran oil levels up to 17.5% concentrate do not negatively affect the apparent digestibility of dietary nutrients.

  15. Correlation between blood lead concentration and iron deficiency in ...

    African Journals Online (AJOL)

    Results: We studied 223 cases including 98 control children and 125 patients. All children had lead intoxication. Mean (±SD) blood lead concentration in the control group was 57.1 ± 25.3 (ranged 20-212) μg/dl and in the patient group was 57 ± 20.4 (ranged 10.9-159) μg/dl with no significant difference (P value = 0.713).

  16. Serial blood pressure measurements

    Directory of Open Access Journals (Sweden)

    N.R. Koehler

    2002-05-01

    Full Text Available The objective of the present investigation was to study the effects of a 60-s interval of venous congestion between two noninvasive measurements of arterial blood pressure (ABP on the fluctuation of ABP, assessed by the standard deviation of the differences between two readings. ABP was measured in 345 successive patients, at rest, four times each. For 269 participants, one pair of readings was obtained with a 60-s interval and the other pair without an interval. For 76 patients, the first pair was read at the same interval, and the second pair had venous congestion interposed and there was no waiting interval. There was no increased ABP oscillation, either when there was no interval between ABP readings, or when venous congestion was interposed compared to pairs of ABP measurements performed with a 60-s interval. There was no increase in ABP oscillations when successive ABP readings were taken without an interval or even with venous congestion interposed. Contrary to the present belief, there seems to be no loss of reliability when blood pressure recordings are taken immediately one after another, in the clinical setting.

  17. Effect of concentrate level on feeding behavior and rumen and blood parameters in dairy goats: relationships between behavioral and physiological parameters and effect of between-animal variability.

    Science.gov (United States)

    Giger-Reverdin, S; Rigalma, K; Desnoyers, M; Sauvant, D; Duvaux-Ponter, C

    2014-07-01

    This work aimed first to compare 2 diets differing in their percentage of concentrate [low (LO): 30% concentrate vs. High (HI): 60% concentrate] by measuring simultaneously feeding behavior, rumen parameters, blood and plasma parameters, and milk yield and composition in 8 mid-lactation goats. The second aim was to study the interrelationships between these variables and to analyze the between-animal variability to better understand the between-animal differences in acidosis susceptibility. All of the animals received the 2 diets ad libitum as total mixed ration according to a crossover design of two 4-wk periods. Mean daily DMI was similar between the 2 diets but the variability was higher for the HI than for the LO diet. Goats produced more milk when fed the HI diet compared with the LO diet but with a lower fat:protein ratio (0.81 vs. 0.99). They ate more rapidly the HI than the LO diet but stopped eating sooner after the afternoon feed allowance, and spent less time chewing. The increase in concentrate percentage modified rumen parameters: the pH and acetate:propionate ratio decreased and total VFA, ammonia, and soluble carbohydrate concentrations increased. Hematocrit, plasma NEFA, and blood K and Ca concentrations decreased but glycemia and uremia increased. Other parameters were not modified: milk fat content, blood pH, and bicarbonate and Na concentrations. A large between-animal variability was detected for all the measured parameters, especially for feeding behavior, with important consequences on rumen and blood parameters. This work confirmed the effects of a high percentage of concentrate on feeding behavior, rumen and blood parameters, and milk production, and some known relationships such as the positive link between rumen pH and chewing index. It also pointed out other relationships between parameters seldom measured at the same time, such as rumen redox potential or blood pH and chewing index, or the negative link between blood and rumen pH. When

  18. Concentration of glucose, insuline, thyroxine (T/sub 4/), triiodthyronine (T/sub 3/) and gastrine in the maternal blood, in the umbilical cord blood of their outcomes in the neonatal blood samples

    Energy Technology Data Exchange (ETDEWEB)

    Osuch-Jaczewska, R; Tomala, J; Adamska, S; Bielecka, W; Mikulska, M; Kalacinska, M; Sieron, G [Slaska Akademia Medyczna, Katowice (Poland)

    1978-01-01

    In the blood samples collected from the mothers, from the umbilical cord of their outcomes and from these neonates after 24 hours of life the following estimations were performed collaterally: The concentration of insulin in 50 mothers and their fetuses and in 34 neonates, concentration of thyroxine (T/sub 4/) in 70 mothers and their fetuses and in 32 neonates, triiodothyronine binding coefficient (WWT/sub 3/) in 60 mothers and their fetuses and neonates, concentration of gastrine in 23 mothers and their fetuses and in 5 neonates. Besides that the concentration of glucose in total blood was established in 300 mothers - their fetuses and neonates. The insuline, WWT/sub 3/ and gastrine were estimated by radioimmune techniques and T/sub 4/ by radiocompetitive technique. The glucose concentration - with the aid of o-toluidine method. Basing on the results, the paper suggests that the fetus and the newborn represent independent unit in the aspect of regulation of the glucose concentration, secretion of insuline, T/sub 3/, T/sub 4/ and gastrine, notwithstanding the possibility of transplacental passage of these hormones exists the correlation coefficients between the maternal and fetal blood concentrations of insuline, T/sub 4/ and WWT/sub 3/ were significant. The cord-blood glucose concentration exhibits a marked correlation with the maternal glicemia. Physiologic, asymptomatic hyperinsulinemia and hyperthyreosis and an increase of gastrine concentration demonstrate the presence, in the fetal and neonatal organisms, of certain compensatory-regulating mechanisms stimulating and inhibiting with feed-back properties, which guarantee the environmental homeostasis.

  19. Elevated blood harmane (1-methyl-9H-pyrido[3,4-b]indole) concentrations in essential tremor.

    Science.gov (United States)

    Louis, Elan D; Jiang, Wendy; Pellegrino, Kathryn M; Rios, Eileen; Factor-Litvak, Pam; Henchcliffe, Claire; Zheng, Wei

    2008-03-01

    Essential tremor (ET) is a widespread late-life neurological disease. Genetic and environmental factors likely play an etiological role. Harmane (1-methyl-9H-pyrido[3,4-b]indole) is a potent tremor-producing neurotoxin. In 2002, we demonstrated elevated blood harmane concentrations in an initial sample of 100 ET cases compared to 100 controls. Between 2002 and 2007, we assembled a new and larger sample of ET cases and controls. We now attempt to replicate our previous findings. Cases and controls were frequency-matched on age, gender, and race. Blood harmane concentrations were quantified by high-performance liquid chromatography. Subjects comprised 150 ET cases and 135 controls (mean age 65.3+/-15.5 vs. 65.5+/-14.2 years, p=0.94). Mean log blood harmane concentration was approximately 50% higher in cases than controls (0.50+/-0.54g(-10)/ml vs. 0.35+/-0.62g(-10)/ml, p=0.038). In a logistic regression analysis, log blood harmane concentration was associated with ET (OR(adjusted) 1.56, 95% CI 1.01-2.42, p=0.04), and odds of ET was 1.90 (95% CI 1.07-3.39, p=0.029) in the highest versus lowest log blood harmane tertile. Log blood harmane was highest in ET cases with familial ET (0.53+/-0.57g(-10)/ml), intermediate in cases with sporadic ET (0.43+/-0.45g(-10)/ml) and lowest in controls (0.35+/-0.62g(-10)/ml) (test for trend, p=0.026). Blood harmane appears to be elevated in ET. The higher concentrations in familial ET suggests that the mechanism may involve genetic factors.

  20. Copeptin, a surrogate marker for arginine vasopressin secretion, is associated with higher glucose and insulin concentrations but not higher blood pressure in obese men

    DEFF Research Database (Denmark)

    Asferg, C L; Andersen, Ulrik Bjørn; Linneberg, A

    2014-01-01

    distribution. METHODS: In 103 obese men (mean age ± standard deviation: 49.4 ± 10.2 years) and 27 normal weight control men (mean age: 51.5 ± 8.4 years), taking no medication, we measured 24-h ambulatory blood pressure, fasting blood concentrations of copeptin, lipids, glucose and insulin, and determined body...... blood pressure (r = 0.11, P = 0.29), 24-h diastolic blood pressure (r = 0.11, P = 0.28), BMI (r = 0.09, P = 0.37), total body fatness percentage (r = 0.10, P = 0.33), android fat mass percentage (r = 0.04, P = 0.66) or serum triglyceride concentrations (r = 0.04; P = 0.68). In contrast, plasma copeptin......, and is associated with abnormalities in glucose and insulin metabolism, but not with higher blood pressure or an android fat distribution in obese men....

  1. Plasma concentration of ionized calcium in healthy iguanas.

    Science.gov (United States)

    Dennis, P M; Bennett, R A; Harr, K E; Lock, B A

    2001-08-01

    To measure plasma concentration of ionized calcium in healthy green iguanas. Prospective study. 9 juvenile and 21 (10 male, 11 female) adult iguanas. Blood samples were obtained from each iguana, and plasma calcium, glucose, phosphorus, uric acid, total protein, albumin, globulin, potassium, and ionized calcium concentrations, aspartate transaminase (AST) activity, and pH were measured. Heparinized blood was used for measurement of ionized calcium concentration and blood pH. A CBC was also performed to assess the health of the iguanas. Significant differences were not detected among the 3 groups (juveniles, males, and females) with regard to ionized calcium concentration. Mean ionized calcium concentration measured in blood was 1.47 +/- 0.105 mmol/L. Significant differences were detected between juveniles and adults for values of phosphorus, glucose, total protein, albumin, globulin, and AST activity. Ionized calcium concentration provides a clinical measurement of the physiologically active calcium in circulation. Evaluation of physiologically active calcium in animals with suspected calcium imbalance that have total plasma calcium concentrations within reference range or in gravid animals with considerably increased total plasma calcium concentrations is vital for determining a therapeutic plan. Accurate evaluation of calcium status will provide assistance in the diagnosis of renal disease and seizures and allow for better evaluation of the health status of gravid female iguanas.

  2. Diabetes mellitus, fasting blood glucose concentration, and risk of vascular disease

    DEFF Research Database (Denmark)

    Sarwar, N; Gao, P; Seshasai, S R Kondapally

    2010-01-01

    BACKGROUND: Uncertainties persist about the magnitude of associations of diabetes mellitus and fasting glucose concentration with risk of coronary heart disease and major stroke subtypes. We aimed to quantify these associations for a wide range of circumstances. METHODS: We undertook a meta-analysis...... of individual records of diabetes, fasting blood glucose concentration, and other risk factors in people without initial vascular disease from studies in the Emerging Risk Factors Collaboration. We combined within-study regressions that were adjusted for age, sex, smoking, systolic blood pressure, and body......-mass index to calculate hazard ratios (HRs) for vascular disease. FINDINGS: Analyses included data for 698 782 people (52 765 non-fatal or fatal vascular outcomes; 8.49 million person-years at risk) from 102 prospective studies. Adjusted HRs with diabetes were: 2.00 (95% CI 1.83-2.19) for coronary heart...

  3. Peripheral vascular effects on auscultatory blood pressure measurement.

    Science.gov (United States)

    Rabbany, S Y; Drzewiecki, G M; Noordergraaf, A

    1993-01-01

    Experiments were conducted to examine the accuracy of the conventional auscultatory method of blood pressure measurement. The influence of the physiologic state of the vascular system in the forearm distal to the site of Korotkoff sound recording and its impact on the precision of the measured blood pressure is discussed. The peripheral resistance in the arm distal to the cuff was changed noninvasively by heating and cooling effects and by induction of reactive hyperemia. All interventions were preceded by an investigation of their effect on central blood pressure to distinguish local effects from changes in central blood pressure. These interventions were sufficiently moderate to make their effect on central blood pressure, recorded in the other arm, statistically insignificant (i.e., changes in systolic [p cooling experiments was statistically significant (p < 0.001). Moreover, both measured systolic (p < 0.004) and diastolic (p < 0.001) pressure decreases during the reactive hyperemia experiments were statistically significant. The findings demonstrate that alteration in vascular state generates perplexing changes in blood pressure, hence confirming experimental observations by earlier investigators as well as predictions by our model studies.

  4. Influence of Estimated Training Status on Anti and Pro-Oxidant Activity, Nitrite Concentration, and Blood Pressure in Middle-Aged and Older Women

    Science.gov (United States)

    Jacomini, André M.; Dias, Danielle da Silva; Brito, Janaina de Oliveira; da Silva, Roberta F.; Monteiro, Henrique L.; Llesuy, Susana; De Angelis, Kátia; Amaral, Sandra L.; Zago, Anderson S.

    2017-01-01

    The purpose of this study was to compare the association between anti and pro-oxidant activity, nitrite concentration, and blood pressure (BP) in middle-aged and older women with different levels of estimated training status (TS). The sample consisted of 155 females (50–84 years) who were submitted to a physical examination to evaluate estimated TS through the “Functional Fitness Battery Test,” BP measurements, and plasma blood samples to evaluate pro-oxidant and antioxidant activity and nitrite concentrations. Participants were separated by age into a middle-aged group (<65 years) and an older (≥65 years) group and then subdivided in each group according to TS. Blood biochemistry was similar between groups. On the other hand, protein oxidation was lower in participants with higher TS, independent of age. Older females with higher TS presented higher nitrite concentrations, lower lipoperoxidation, and lower values of BP compared with those with lower TS. Lower GPx activity was observed in participants with higher TS compared with middle-aged with lower TS. Thus, our results suggest that good levels of TS may be associated with lower oxidative stress and higher nitrite concentration and may contribute to maintain normal or reduced blood pressure values. PMID:28326041

  5. Measurement of the arterial concentration of Gd-DTPA using MRI: a step toward quantitative perfusion imaging

    DEFF Research Database (Denmark)

    Fritz-Hansen, T; Rostrup, Egill; Larsson, H B

    1996-01-01

    A noninvasive method using an inversion recovery turbo-FLASH for dynamic measurement of the arterial input function represented by the bolus passage of Gd-DTPA in the descending aorta is presented, and the results are compared with the input function obtained by arterial blood samples. A good...... accordance between the two input functions was found, indicating that it is possible to measure the input function to the myocardium using MRI. A variation between the two concentration curves of 5% at upslope, 2.7% at peak point, and ... inversion time peak concentration....

  6. Blood folate concentrations among women of childbearing age by race/ethnicity and acculturation, NHANES 2001-2010.

    Science.gov (United States)

    Marchetta, Claire M; Hamner, Heather C

    2016-01-01

    Hispanic women have higher rates of neural tube defects and report lower total folic acid intakes than non-Hispanic white (NHW) women. Total folic acid intake, which is associated with neural tube defect risk reduction, has been found to vary by acculturation factors (i.e. language preference, country of origin, or time spent in the United States) among Hispanic women. It is unknown whether this same association is present for blood folate status. The objective of this research was to assess the differences in serum and red blood cell (RBC) folate concentrations between NHW women and Mexican American (MA) women and among MA women by acculturation factors. Cross-sectional data from the 2001-2010 National Health and Nutrition Examination Survey (NHANES) were used to investigate how blood folate concentrations differ among NHW or MA women of childbearing age. The impact of folic acid supplement use on blood folate concentrations was also examined. MA women with lower acculturation factors had lower serum and RBC folate concentrations compared with NHW women and to their more acculturated MA counterparts. Consuming a folic acid supplement can minimize these disparities, but MA women, especially lower acculturated MA women, were less likely to report using supplements. Public health efforts to increase blood folate concentrations among MA women should consider acculturation factors when identifying appropriate interventions. © 2014 John Wiley & Sons Ltd.

  7. Determination of Blood Glucose Concentration by Using Wavelet Transform and Neural Networks

    Directory of Open Access Journals (Sweden)

    Vajravelu Ashok

    2013-03-01

    Full Text Available Background: Early and non-invasive determination of blood glucose level is of great importance. We aimed to present a new technique to accurately infer the blood glucose concentration in peripheral blood flow using non-invasive optical monitoring system.Methods: The data for the research were obtained from 900 individuals. Of them, 750 people had diabetes mellitus (DM. The system was designed using a helium neon laser source of 632.8 nm wavelength with 5mW power, photo detectors and digital storage oscilloscope. The laser beam was directed through a single optical fiber to the index finger and the scattered beams were collected by the photo detectors placed circumferentially to the transmitting fiber. The received signals were filtered using band pass filter and finally sent to a digital storage oscilloscope. These signals were then decomposed into approximation and detail coefficients using modified Haar Wavelet Transform. Back propagation neural and radial basis functions were employed for the prediction of blood glucose concentration.Results: The data of 450 patients were randomly used for training, 225 for testing and the rest for validation. The data showed that outputs from radial basis function were nearer to the clinical value. Significant variations could be seen from signals obtained from patients with DM and those without DM.Conclusion: The proposed non-invasive optical glucose monitoring system is able to predict the glucose concentration by proving that there is a definite variation in hematological distribution between patients with DM and those without DM.

  8. Photoacoustic measurements of red blood cell oxygen saturation in blood bags in situ

    Science.gov (United States)

    Pinto, Ruben N.; Bagga, Karan; Douplik, Alexandre; Acker, Jason P.; Kolios, Michael C.

    2017-03-01

    Red blood cell (RBC) transfusion is a critical component of the health care services. RBCs are stored in blood bags in hypothermic temperatures for a maximum of 6 weeks post donation. During this in vitro storage period, RBCs have been documented to undergo changes in structure and function due to mechanical and biochemical stress. Currently, there are no assessment methods that monitor the quality of RBCs within blood bags stored for transfusion. Conventional assessment methods require the extraction of samples, consequently voiding the sterility of the blood bags and potentially rendering them unfit for transfusions. It is hypothesized that photoacoustic (PA) technology can provide a rapid and non-invasive indication of RBC quality. In this study, a novel PA setup was developed for the acquisition of oxygen saturation (SO2) of two blood bags in situ. These measurements were taken throughout the lifespan of the blood bags (42 days) and compared against the clinical gold standard method of the blood gas analyzer (BGA). SO2 values of the blood bags increased monotonically throughout the storage period. A strong correlation between PA SO2 and BGA SO2 was found, however, PA values were on average 3.5% lower. Both techniques found the bags to increase by an SO2 of approximately 20%, and measured very similar rates of SO2 change. Future work will be focused on determining the cause of discrepancy between SO2 values acquired from PA versus BGA, as well as establishing links between the measured SO2 increase and other changes in RBC in situ.

  9. Psychomotor performance, subjective and physiological effects and whole blood Δ⁹-tetrahydrocannabinol concentrations in heavy, chronic cannabis smokers following acute smoked cannabis.

    Science.gov (United States)

    Schwope, David M; Bosker, Wendy M; Ramaekers, Johannes G; Gorelick, David A; Huestis, Marilyn A

    2012-07-01

    Δ⁹-Tetrahydrocannabinol (THC) is the illicit drug most frequently observed in accident and driving under the influence of drugs investigations. Whole blood is often the only available specimen collected during such investigations, yet few studies have examined relationships between cannabis effects and whole blood concentrations following cannabis smoking. Nine male and one female heavy, chronic cannabis smokers resided on a closed research unit and smoked ad libitum one 6.8% THC cannabis cigarette. THC, 11-hydroxy-THC and 11-nor-9-carboxy-THC were quantified in whole blood and plasma. Assessments were performed before and up to 6 h after smoking, including subjective [visual analog scales (VAS) and Likert scales], physiological (heart rate, blood pressure and respirations) and psychomotor (critical-tracking and divided-attention tasks) measures. THC significantly increased VAS responses and heart rate, with concentration-effect curves demonstrating counter-clockwise hysteresis. No significant differences were observed for critical-tracking or divided-attention task performance in this cohort of heavy, chronic cannabis smokers. The cannabis influence factor was not suitable for quantifying psychomotor impairment following cannabis consumption and was not precise enough to determine recent cannabis use with accuracy. These data inform our understanding of impairment and subjective effects following acute smoked cannabis and interpretation of whole blood cannabinoid concentrations in forensic investigations.

  10. Critical evaluation of blood volume measurements during hemodialysis.

    Science.gov (United States)

    Dasselaar, Judith J; van der Sande, Frank M; Franssen, Casper F M

    2012-01-01

    Devices that continuously measure relative blood volume (RBV) changes during hemodialysis (HD) are increasingly used for the prevention of dialysis hypotension and fine-tuning of dry weight. However, RBV measurements are subject to various limitations. First, RBV devices provide information on relative blood volume changes but not on absolute blood volume. Since blood volume varies with the hydration status, identical reductions of RBV may result in very different absolute blood volumes at the end of HD. Second, RBV changes underestimate the change of total blood volume due to translocation of lower-hematocrit blood from the microcirculation to the central circulation. Third, changes in posture before and during HD, food intake, exercise, and administration of intravenous fluids may influence the validity of the RBV measurement. Fourth, results obtained by various RBV devices show large interdevice differences. Finally, although a fall in blood volume is an important factor in dialysis hypotension, frank dialysis hypotension only occurs when the cardiovascular compensatory mechanisms can no longer compensate for the reduction in blood volume. Therefore, the dialysis staff should not exclusively focus on RBV, but also search for opportunities in the dialysis prescription to facilitate cardiovascular compensatory mechanisms, e.g. by lowering dialysate temperature. In the opinion of the authors, routine RBV monitoring should be used with caution until the major conceptual and methodological problems that are inherent to the indirect RBV estimation are clarified. Copyright © 2012 S. Karger AG, Basel.

  11. The optimum measurement precision evaluation for blood components using near-infrared spectra on 1000-2500 nm

    Science.gov (United States)

    Zhang, Ziyang; Sun, Di; Han, Tongshuai; Guo, Chao; Liu, Jin

    2016-10-01

    In the non-invasive blood components measurement using near infrared spectroscopy, the useful signals caused by the concentration variation in the interested components, such as glucose, hemoglobin, albumin etc., are relative weak. Then the signals may be greatly disturbed by a lot of noises in various ways. We improved the signals by using the optimum path-length for the used wavelength to get a maximum variation of transmitted light intensity when the concentration of a component varies. And after the path-length optimization for every wavelength in 1000-2500 nm, we present the detection limits for the components, including glucose, hemoglobin and albumin, when measuring them in a tissue phantom. The evaluated detection limits could be the best reachable precision level since it assumed the measurement uses a high signal-to-noise ratio (SNR) signal and the optimum path-length. From the results, available wavelengths in 1000-2500 nm for the three component measurements can be screened by comparing their detection limit values with their measurement limit requirements. For other blood components measurement, the evaluation their detection limits could also be designed using the method proposed in this paper. Moreover, we use an equation to estimate the absorbance at the optimum path-length for every wavelength in 1000-2500 nm caused by the three components. It could be an easy way to realize the evaluation because adjusting the sample cell's size to the precise path-length value for every wavelength is not necessary. This equation could also be referred to other blood components measurement using the optimum path-length for every used wavelength.

  12. Non-invasive method to detect the changes of glucose concentration in whole blood using photometric technique.

    Science.gov (United States)

    Rajan, Shiny Amala Priya; Towe, Bruce C

    2014-01-01

    A non-invasive method is developed to monitor rapid changes in blood glucose levels in diabetic patients. The system depends on an optical cell built with a LED that emits light of wavelength 535nm, which is a peak absorbance of hemoglobin. As the glucose concentration in blood decreases, its osmolarity also decreases and the Red Blood Cells (RBCs) swell and decrease the path length absorption coefficient. Decreasing absorption coefficient increases the transmission of light through the whole blood. The system was tested with a constructed optical cell that held whole blood in a capillary tube. As expected the light transmitted to the photodiode increases with decreasing glucose concentration. The average response time of the system was between 30-40 seconds.

  13. Monthly variation in faeces:blood concentration ratio of persistent organic pollutants over the first year of life: a case study of one infant

    Energy Technology Data Exchange (ETDEWEB)

    Chen, Yiqin, E-mail: y.chen16@uq.edu.au [The University of Queensland, National Research Centre for Environmental Toxicology (Australia); McLachlan, Michael S. [Department of Environmental Science and Analytical Chemistry (ACES), Stockholm University (Sweden); Kaserzon, Sarit; Wang, Xianyu; Weijs, Liesbeth; Gallen, Michael [The University of Queensland, National Research Centre for Environmental Toxicology (Australia); Toms, Leisa-Maree L. [School of Public Health and Social Work and Institute of Health and Biomedical Innovation, Faculty of Health, Queensland University of Technology (Australia); Li, Yan [The University of Queensland, National Research Centre for Environmental Toxicology (Australia); Aylward, Lesa L. [The University of Queensland, National Research Centre for Environmental Toxicology (Australia); Summit Toxicology, LLP, Falls Church, VA (United States); Sly, Peter D. [Children’s Health and Environment Program, Queensland Children’s Medical Research Institute, Brisbane (Australia); Child Health Research Centre, The University of Queensland (Australia); Mueller, Jochen F. [The University of Queensland, National Research Centre for Environmental Toxicology (Australia)

    2016-05-15

    Previous studies have found that the concentrations of a range of persistent organic pollutants (POPs) in faeces is linearly proportional to the POP concentrations in blood of human adults irrespective of age and gender. In order to investigate the correlation between POP concentrations in faeces and blood in infants, the monthly variation of POP concentrations in faeces over the first year of life of one infant was investigated in this study and compared to modelled blood concentrations. Faecal samples were collected from one male infant daily. The samples were pooled by month and analysed for three selected POPs (2,2{sup ′},4,4{sup ′},5,5{sup ′}-Hexachlorobiphenyl (PCB153), p,p′-dichlorodiphenyldichloroethylene (p,p′-DDE) and 2,2{sup ′},4,4′-tetrabromodiphenyl ether (BDE47)). The POP concentrations in faecal samples increased for the first four months by a factor of 2.9, 4.9 and 1.4 for PCB153, BDE47, and p,p′-DDE, respectively. The faecal concentrations of all POPs decreased rapidly following the introduction of formula and solid food to the diet and subsequent weaning of the infant. Further, a one-compartment model was developed to estimate the daily POP concentrations in the blood of the infant. The POP concentrations in blood were predicted to vary much less over the first year than those observed in faeces. The faeces:blood concentration ratio of selected POPs (K{sub fb}) differed significantly (P<0.0001) between the period before and after weaning, and observed changes in K{sub fb} are far greater than the uncertainty in the estimated K{sub fb}. A more stable K{sub fb} after weaning indicates the possibility of applying the stable K{sub fb} values for non-invasive assessment of internal exposure in infants after weaning. The intra-individual variation in K{sub fb} in infants is worthy of further investigation. - Highlights: • Measured POPs concentrations in faecal samples decreased rapidly following weaning. • Ratio of faecal:blood

  14. Relationship of concentrations of cortisol in hair with health, biomarkers in blood, and reproductive status in dairy cows.

    Science.gov (United States)

    Burnett, Tracy A; Madureira, Augusto M L; Silper, Bruna F; Tahmasbi, Abdolmansour; Nadalin, Audrey; Veira, Douglas M; Cerri, Ronaldo L A

    2015-07-01

    Hair cortisol has been used to measure chronic stress in dairy cows as it offers the advantage of being noninvasive, fast, and able to indicate levels of cortisol over long periods. The aim of this study was to determine the associations between hair cortisol with clinical disorders, reproductive status, and the development of subclinical endometritis in dairy cows. Furthermore, we aimed to determine the association between hair cortisol concentrations and blood markers associated with metabolic status and acute inflammation. In experiment 1, cows (n=64) were hair sampled every 3wk from the tail switch beginning at calving (d 0) until d 126 for cortisol analysis; blood samples were collected every 3wk from d 0 until 42 for β-hydroxybutyrate and glucose analysis. In experiment 2, cows (n=54) were chosen retrospectively by diagnosis of subclinical endometritis (END), subclinical endometritis and at least 1 clinical disease (END+CLIN), or as healthy (control) using a cytobrush and ultrasonography at 30±3d in milk. At the same time, animals were hair sampled for cortisol analysis and blood sampled for haptoglobin and ceruloplasmin analysis. Health records were recorded throughout both experimental periods. Animals with clinical disease presented higher cortisol concentrations than clinically healthy animals in experiment 1 [geometric mean (95% confidence interval); 8.8 (7.8, 9.9) vs. 10.7 (9.6, 12.0) pg/mg]; however, animals diagnosed with subclinical endometritis in experiment 2 did not differ in hair cortisol concentrations [11.7 (9.8, 14.0), 12.2 (9.3, 15.9), 10.5 (8.1, 13.6) pg/mg for control, END, and END+CLIN, respectively]. In experiment 1, an effect of sample day was noted, where d 21 had higher cortisol concentrations than d 42, 84, and 126, but not from d 0 for both parities. Within both experiments, a parity effect was present where multiparous animals consistently had higher cortisol concentrations than primiparous animals. Multiparous cows that became

  15. Examination of androgen- and estrogen concentrations in the blood of male dogs with and without perineal hernia

    International Nuclear Information System (INIS)

    Pemsel, K.

    1985-10-01

    Concentrations of dehydroepiandrosterone, androstendione and testosterone were measured in the blood of male dogs by radioimmunoassay. Mean values were 0.67 - 1.51 ng/ml DHA, 1.06 -1.30 ng/ml AD, 1.52 - 1.92 ng/ml T and 22 - 25 pg/ml total oestrogens. The hypothesis that a hormonal unbalance is an important etiological factor in hermia perinealis of dogs could not be corroborated. (P.W.)

  16. Postmortem Brain and Blood Reference Concentrations of Alprazolam, Bromazepam, Chlordiazepoxide, Diazepam, and their Metabolites and a Review of the Literature

    DEFF Research Database (Denmark)

    Skov, Louise; Holm, Karen Marie Dollerup; Johansen, Sys Stybe

    2016-01-01

    with median brain-blood ratios ranging from 1.1 to 2.3. A positive correlation between brain and blood concentrations was found with R(2) values from 0.51 to 0.95. Our reported femoral blood concentrations concur with literature values, but sparse information on brain concentration was available. Drug...

  17. In vivo evaluation of femoral blood flow measured with magnetic resonance

    International Nuclear Information System (INIS)

    Henriksen, O.; Staahlberg, F.; Thomsen, C.; Moegelvang, J.; Persson, B.; Lund Univ.

    1989-01-01

    Quantitative measurements of blood flow based on magnetic resonance imaging (MRI) using conventional multiple spin echo sequences were evaluated in vivo in healthy young volunteers. Blood flow was measured using MRI in the femoral vein. The initial slope of the multiple spin echo decay curve, corrected for the T2 decay of non-flowing blood was used to calculate the blood flow. As a reference, the blood flow in the femoral artery was measured simultaneously with an invasive indicator dilution technique. T2 of non-flowing blood was measured in vivo in popliteal veins during regional circulatory arrest. The mean T2 of non-flowing blood was found to be 105±31 ms. The femoral blood flow ranged between 0 and 643 ml/min measured with MRI and between 280 and 531 ml/min measured by the indicator dilution technique. There was thus poor agreement between the two methods. The results indicate that in vivo blood flow measurements made with MRI based on wash-out effects, commonly used in multiple spin echo imaging, do not give reliable absolute values for blood flow in the femoral artery or vein. (orig.)

  18. Effect of breathing fluctuations on cerebral blood flow in demented patients and its correction method using end-tidal CO/sub 2/ concentration

    Energy Technology Data Exchange (ETDEWEB)

    Komatani, Akio; Yamaguchi, Koichi; Kera, Masahiro; Takanashi, Toshiyasu; Shinohara, Masao; Kawakatsu, Shinobu; Yazaki, Mitsuyasu

    1989-02-01

    During mouthpiece respiration of Xe-133 for a measurement of regional cerebral blood flow (rCBF), the breathing pattern of patients fluctuated and it caused a change of end-tidal CO/sub 2/ concentration that had an excellent correlation with PaCO/sub 2/ in patients without respiratory disease. The end-tidal CO/sub 2/ concentration of demented patients varied within lower ranges than senile control group. The range of fluctuation on the end-tidal CO/sub 2/ concentration was dependent on the type and the degree of dementia, and it fluctuated most widely at the middle stage of Alzheimer disease. Mean cerebral blood flow increased by 13.9% for each l% increase in end-tidal CO/sub 2/ concentration (3.6%/mmHg PaCO/sub 2/) in the case of demented patients without cerebrovascular disease. To improve the reliability of rCBF in demented patients, especially in Alzheimer disease, the correction of rCBF data for end-tidal CO/sub 2/ concentration should be performed.

  19. Blood Lead Concentrations in Jamaican Children with and without Autism Spectrum Disorder

    Science.gov (United States)

    Rahbar, Mohammad H.; Samms-Vaughan, Maureen; Dickerson, Aisha S.; Loveland, Katherine A.; Ardjomand-Hessabi, Manouchehr; Bressler, Jan; Shakespeare-Pellington, Sydonnie; Grove, Megan L.; Pearson, Deborah A.; Boerwinkle, Eric

    2014-01-01

    Autism Spectrum Disorder (ASD) is a neurodevelopmental disorder manifesting by early childhood. Lead is a toxic metal shown to cause neurodevelopmental disorders in children. Several studies have investigated the possible association between exposure to lead and ASD, but their findings are conflicting. Using data from 100 ASD cases (2–8 years of age) and their age- and sex-matched typically developing controls, we investigated the association between blood lead concentrations (BLC) and ASD in Jamaican children. We administered a questionnaire to assess demographic and socioeconomic information as well as exposure to potential lead sources. We used General Linear Models (GLM) to assess the association of BLC with ASD status as well as with sources of exposure to lead. In univariable GLM, we found a significant difference between geometric mean blood lead concentrations of ASD cases and controls (2.25 μg/dL cases vs. 2.73 μg/dL controls, p < 0.05). However, after controlling for potential confounders, there were no significant differences between adjusted geometric mean blood lead concentrations of ASD cases and controls (2.55 μg/dL vs. 2.72 μg/dL, p = 0.64). Our results do not support an association between BLC and ASD in Jamaican children. We have identified significant confounders when assessing an association between ASD and BLC. PMID:25546274

  20. Blood Lead Concentrations in Jamaican Children with and without Autism Spectrum Disorder

    Directory of Open Access Journals (Sweden)

    Mohammad H. Rahbar

    2014-12-01

    Full Text Available Autism Spectrum Disorder (ASD is a neurodevelopmental disorder manifesting by early childhood. Lead is a toxic metal shown to cause neurodevelopmental disorders in children. Several studies have investigated the possible association between exposure to lead and ASD, but their findings are conflicting. Using data from 100 ASD cases (2–8 years of age and their age- and sex-matched typically developing controls, we investigated the association between blood lead concentrations (BLC and ASD in Jamaican children. We administered a questionnaire to assess demographic and socioeconomic information as well as exposure to potential lead sources. We used General Linear Models (GLM to assess the association of BLC with ASD status as well as with sources of exposure to lead. In univariable GLM, we found a significant difference between geometric mean blood lead concentrations of ASD cases and controls (2.25 μg/dL cases vs. 2.73 μg/dL controls, p < 0.05. However, after controlling for potential confounders, there were no significant differences between adjusted geometric mean blood lead concentrations of ASD cases and controls (2.55 μg/dL vs. 2.72 μg/dL, p = 0.64. Our results do not support an association between BLC and ASD in Jamaican children. We have identified significant confounders when assessing an association between ASD and BLC.

  1. Development of a high-sensitivity and portable cell using Helmholtz resonance for noninvasive blood glucose-level measurement based on photoacoustic spectroscopy.

    Science.gov (United States)

    Tachibana, K; Okada, K; Kobayashi, R; Ishihara, Y

    2016-08-01

    We describe the possibility of high-sensitivity noninvasive blood glucose measurement based on photoacoustic spectroscopy (PAS). The demand for noninvasive blood glucose-level measurement has increased due to the explosive increase in diabetic patients. We have developed a noninvasive blood glucose-level measurement based on PAS. The conventional method uses a straight-type resonant cell. However, the cell volume is large, which results in a low detection sensitivity and difficult portability. In this paper, a small-sized Helmholtz-type resonant cell is proposed to improve detection sensitivity and portability by reducing the cell dead volume. First, the acoustic property of the small-sized Helmholtz-type resonant cell was evaluated by performing an experiment using a silicone rubber. As a result, the detection sensitivity of the small-sized Helmholtz-type resonant cell was approximately two times larger than that of the conventional straight-type resonant cell. In addition, the inside volume was approximately 30 times smaller. Second, the detection limits of glucose concentration were estimated by performing an experiment using glucose solutions. The experimental results showed that a glucose concentration of approximately 1% was detected by the small-sized Helmholtz-type resonant cell. Although these results on the sensitivity of blood glucose-level measurement are currently insufficient, they suggest that miniaturization of a resonance cell is effective in the application of noninvasive blood glucose-level measurement.

  2. Measurement of adenosine triphosphate and 2,3-diphosphoglycerate in stored blood with 31P nuclear magnetic resonance spectroscopy.

    Science.gov (United States)

    Ambruso, D R; Hawkins, B; Johnson, D L; Fritzberg, A R; Klingensmith, W C; McCabe, E R

    1986-06-01

    Conditions for blood storage are chosen to assure adequate levels of adenosine triphosphate (ATP) and 2,3-diphosphoglycerate (2,3-DPG). Because of the invasive nature of the techniques, biochemical assays are not routinely used to measure levels of these compounds in stored blood. However, 31P NMR spectroscopy measures phosphorylated intermediates in intact cells and could be used without disruption of the storage pack. We compared levels of ATP and 2,3-DPG measured by 31P spectroscopy and standard enzyme-linked biochemical assays in whole blood (WB) and packed red blood cells (PRBCs) at weekly intervals during a 35-day storage period. NMR demonstrated a marked decrease in 2,3-DPG and an increase in inorganic phosphate after the first week of storage. No significant differences in ATP concentrations were seen in WB during the storage period, but a significant decrease in ATP in PRBCs was documented. There was good agreement in levels of ATP and 2,3-DPG measured by NMR and biochemical techniques. 31P NMR spectroscopy is a noninvasive technique for measuring ATP and 2,3-DPG which has a potential use in quality assurance of stored blood.

  3. Blood lead concentration and related factors in Korea from the 2008 National Survey for Environmental Pollutants in the Human Body.

    Science.gov (United States)

    Jeong, Seong Wook; Lee, Chae Kwan; Suh, Chun Hui; Kim, Kun Hyung; Son, Byung Chul; Kim, Jeong Ho; Lee, Jong Tae; Lee, Soo Woong; Park, Yeong Beom; Lee, Jong Wha; Yu, Seung-Do; Moon, Chan Seok; Kim, Dae Hwan; Lee, Sang Yoon

    2014-11-01

    This study evaluated blood lead concentrations in the Korean general population and the correlation between various exposure sources using data from the 2008 Korea National Survey for Environmental Pollutants in the Human Body (National Institute of Environmental Research, Korea). The general and occupational characteristics were gathered from 5136 participants who were 20 years of age and older using a structured questionnaire. Blood lead concentrations were analyzed using an atomic absorption spectrophotometer. Statistical analysis was performed using multiple linear regressions of the log lead concentrations to the independent variables such as age, gender, smoke, herbal medication and drug consumption, drinking water, and living area. Geometric mean (GM) blood lead concentrations in Korean adults were 19.7 μg/l. The blood lead concentrations increased with age; the highest concentrations were found in the 50-69-year age group (pdrug consumption were higher than those who did not (plead concentration (plead concentration (plead concentration, but not significantly. For drinking water, the underground water (spring or well water) drinking group had higher concentrations than other types of water drinking groups, but not significantly (p=0.063). The blood lead concentrations by occupation were significant (plead concentrations tended to decrease with increasing delivery times, but not significantly. The blood lead concentration (GM) of the general adult population in Korea has decreased over time from 45.8 μg/l (1999) to 19.7 μg/l (2008). Although it is still higher than in other countries such as the United States and Canada, it is rapidly decreasing. Gender, age, smoking and alcohol drinking status, herbal medication and drug consumption, education level, living area and occupation were significantly related to the blood lead concentrations in Korea. Copyright © 2014. Published by Elsevier GmbH.

  4. Auscultatory versus oscillometric measurement of blood pressure in octogenarians

    DEFF Research Database (Denmark)

    Rosholm, Jens-Ulrik; Pedersen, Sidsel Arnspang; Matzen, Lars

    2012-01-01

    Auscultatory measurement using a sphygmomanometer has been the predominant method for clinical estimation of blood pressure, but it is now rapidly being replaced by oscillometric measurement.......Auscultatory measurement using a sphygmomanometer has been the predominant method for clinical estimation of blood pressure, but it is now rapidly being replaced by oscillometric measurement....

  5. In vivo measurements of brain glucose transport using the reversible michaelis-menten model and simultaneous measurements of cerebral blood flow changes during hypoglycemia

    OpenAIRE

    Choi, I.-Y.; Lee, S.-P.; Kim, S.-G.; Gruetter, R.

    2001-01-01

    Glucose is the major substrate that sustains normal brain function. When the brain glucose concentration approaches zero, glucose transport across the blood-brain barrier becomes rate limiting for metabolism during, for example, increased metabolic activity and hypoglycemia. Steady-state brain glucose concentrations in α-chloralose anesthetized rats were measured noninvasively as a function of plasma glucose. The relation between brain and plasma glucose was linear at 4.5 to 30 mmol/L plasma ...

  6. Optoacoustic measurements of human placenta and umbilical blood oxygenation

    Science.gov (United States)

    Nanovskaya, T. N.; Petrov, I. Y.; Petrov, Y.; Patrikeeva, S. L.; Ahmed, M. S.; Hankins, G. D. V.; Prough, D. S.; Esenaliev, R. O.

    2016-03-01

    Adequate oxygenation is essential for normal embryogenesis and fetal growth. Perturbations in the intrauterine oxidative environment during pregnancy are associated with several pathophysiological disorders such as pregnancy loss, preeclampsia, and intrauterine growth restriction. We proposed to use optoacoustic technology for monitoring placental and fetal umbilical blood oxygenation. In this work, we studied optoacoustic monitoring of oxygenation in placenta and umbilical cord blood ex vivo using technique of placenta perfusion. We used a medical grade, nearinfrared, tunable, optoacoustic system developed and built for oxygenation monitoring in blood vessels and in tissues. First, we calibrated the system for cord blood oxygenation measurements by using a CO-Oximeter (gold standard). Then we performed validation in cord blood circulating through the catheters localized on the fetal side of an isolated placental lobule. Finally, the oxygenation measurements were performed in the perfused placental tissue. To increase or decrease blood oxygenation, we used infusion of a gas mixture of 95% O2 + 5% CO2 and 95% N2 + 5% CO2, respectively. In placental tissue, up to four cycles of changes in oxygenation were performed. The optoacoustically measured oxygenation in circulating cord blood and in placental lobule closely correlated with the actual oxygenation data measured by CO-Oximeter. We plan to further test the placental and cord blood oxygenation monitoring with optoacoustics in animal and clinical studies.

  7. Performance of a coincidence based blood activity monitor

    International Nuclear Information System (INIS)

    Moses, W.W.

    1989-12-01

    A new device has been constructed that measures the positron emitting radio-tracer concentration in arterial blood by extracting blood with a peristaltic pump, then measuring the activity concentration by detecting coincident pairs of 511 keV photons with a pair of heavy inorganic scintillators attached to photomultiplier tubes. The sensitivity of this device is experimentally determined to be 610 counts/second per μCi/ml, and has a paralyzing dead time of 1.2 μs, so is capable of measuring blood activity concentration as high as 1 mCi/ml. Its performance is compared to two other blood monitoring methods: discrete blood samples counted with a well counter and device that uses a plastic scintillator to directly detect positrons. The positron detection efficiency of this device for 18 F is greater than the plastic scintillation counter, and also eliminates the radioisotope dependent correction factors necessary to convert count rate to absolute concentration. Coincident photon detection also has the potential of reducing the background compared to direct positron detection, thereby increasing the minimum detectable isotope concentration. 10 refs., 6 figs

  8. In vivo evaluation of femoral blood flow measured with magnetic resonance

    DEFF Research Database (Denmark)

    Henriksen, O; Ståhlberg, F; Thomsen, C

    1989-01-01

    , corrected for the T2 decay of non-flowing blood was used to calculate the blood flow. As a reference, the blood flow in the femoral artery was measured simultaneously with an invasive indicator dilution technique. T2 of non-flowing blood was measured in vivo in popliteal veins during regional circulatory...... arrest. The mean T2 of non-flowing blood was found to be 105 +/- 31 ms. The femoral blood flow ranged between 0 and 643 ml/min measured with MRI and between 280 and 531 ml/min measured by the indicator dilution technique. There was thus poor agreement between the two methods. The results indicate......Quantitative measurements of blood flow based on magnetic resonance imaging (MRI) using conventional multiple spin echo sequences were evaluated in vivo in healthy young volunteers. Blood flow was measured using MRI in the femoral vein. The initial slope of the multiple spin echo decay curve...

  9. TREATMENT OF HYPERTENSION USING TELEMEDICAL HOME BLOOD PRESSURE MEASUREMENTS

    DEFF Research Database (Denmark)

    Hoffmann-Petersen, N; Lauritzen, T; Bech, J N

    2015-01-01

    OBJECTIVE: Telemonitoring of home blood pressure measurements (TBPM) is a new and promising supplement to diagnosis, control and treatment of hypertension. We wanted to compare the outcome of antihypertensive treatment based on TBPM and conventional monitoring of blood pressure. DESIGN AND METHOD...... of the measurements and subsequent communication by telephone or E-mail. In the control group, patients received usual care. Primary outcome was reduction in daytime ambulatory blood pressure measurements (ABPM) from baseline to 3 months' follow-up. RESULTS: In both groups, daytime ABPM decreased significantly....../181), p = 0.34. Blood pressure reduction in the TBPM group varied with the different practices. CONCLUSIONS: No further reduction in ABPM or number of patients reaching blood pressure targets was observed when electronic transmission of TBPM was applied in the treatment of hypertension by GPs. Thus...

  10. Relationship of blood lead levels to obstetric outcome

    Energy Technology Data Exchange (ETDEWEB)

    Angell, N.F.; Lavery, J.P.

    1982-01-01

    Lead represents a significant environmental hazard to pregnant women and their offspring. Exposure to high environmental levels of lead has been associated with spontaneous abortion, premature rupture of fetal membranes (PROM), and preterm delivery. The relationship between lower exposures and obstetric complications is unknown. The concentration of lead in the blood was measured in 635 specimens of umbilical cord blood collected at delivery. No relationship was found between concentrations of lead in cord blood and the incidence of PROM, preterm delivery, preeclampsia, or meconium staining. Maternal and infant capillary blood was collected 24 hours post partum from 154 of these deliveries. The concentrations of lead in the blood did not vary significantly among cord, infant, and maternal samples, and the three measurements were highly correlated. Levels of zinc protoporphyrin (ZnP) were increased in cord blood as compared with mothers' blood, but no concentration-response relationships between the ratio of cord ZnP to maternal ZnP and lead were found.

  11. Trial on MR portal blood flow measurement with phase contrast technique

    International Nuclear Information System (INIS)

    Tsunoda, Masatoshi; Kimoto, Shin; Togami, Izumi

    1991-01-01

    Portal blood flow measurement is considered to be important for the analysis of hemodynamics in various liver diseases. The Doppler ultrasound method has been used extensively during the past several years for measuring portal blood flow, as a non-invasive method. However, the Doppler ultrasound technique do not allow the portal blood flow to be measured in cases of obesity, with much intestinal gas, and so on. In this study, we attempted to measure the blood flow in the main trunk of portal vein as an application of MR phase contrast technique to the abdominal region. In the flow phantom study, the flow volumes and the velocities measured by phase contrast technique showed a close correlation with those measured by electromagnetic flowmeter. In the clinical study with 10 healthy volunteers, various values of portal blood flow were obtained. Mean portal blood flow could be measured within the measuring time (about 8 minutes) under natural breathing conditions. Phase contrast technique is considered to be useful for the non-invasive measurement of portal blood flow. (author)

  12. Measurement of blood coagulation with considering RBC aggregation through a microchip-based light transmission aggregometer.

    Science.gov (United States)

    Lim, Hyunjung; Nam, Jeonghun; Xue, Shubin; Shin, Sehyun

    2011-01-01

    Even though blood coagulation can be tested by various methods and techniques, the effect of RBC aggregation on blood coagulation is not fully understood. The present study monitored clot formation in a microchip-based light transmission aggregometer. Citrated blood samples with and without the addition of calcium ion solution were initially disaggregated by rotating a stirrer in the microchip. After abrupt stop of the rotating stirrer, the transmitted light intensity over time was recorded. The syllectogram (light intensity vs. time graph) manifested a rapid increase that is associated with RBC aggregation followed by a decrease that is associated with blood coagulation. The time to reach the peak point was used as a new index of coagulation time (CT) and ranged from 200 to 500 seconds in the present measurements. The CT was inversely proportional to the concentration of fibrinogen, which enhances RBC aggregation. In addition, the CT was inversely proportional to the hematocrit, which is similar to the case of the prothrombin time (PT), as measured by a commercial coagulometer. Thus, we carefully concluded that RBC aggregation should be considered in tests of blood coagulation.

  13. Prediction Methods for Blood Glucose Concentration

    DEFF Research Database (Denmark)

    -day workshop on the design, use and evaluation of prediction methods for blood glucose concentration was held at the Johannes Kepler University Linz, Austria. One intention of the workshop was to bring together experts working in various fields on the same topic, in order to shed light from different angles...... discussions which allowed to receive direct feedback from the point of view of different disciplines. This book is based on the contributions of that workshop and is intended to convey an overview of the different aspects involved in the prediction. The individual chapters are based on the presentations given...... in the process of writing this book: All authors for their individual contributions, all reviewers of the book chapters, Daniela Hummer for the entire organization of the workshop, Boris Tasevski for helping with the typesetting, Florian Reiterer for his help editing the book, as well as Oliver Jackson and Karin...

  14. Measurement of the ultrasound attenuation and dispersion in whole human blood and its components from 0-70 MHz.

    Science.gov (United States)

    Treeby, Bradley E; Zhang, Edward Z; Thomas, Alison S; Cox, Ben T

    2011-02-01

    The ultrasound attenuation coefficient and dispersion from 0-70 MHz in whole human blood and its components (red blood cells and plasma) at 37°C is reported. The measurements are made using a fixed path substitution technique that exploits optical mechanisms for the generation and detection of ultrasound. This allows the measurements to cover a broad frequency range with a single source and receiver. The measured attenuation coefficient and dispersion in solutions of red blood cells and physiological saline for total haemoglobin concentrations of 10, 15 and 20 g/dL are presented. The attenuation coefficient and dispersion in whole human blood taken from four healthy volunteers by venipuncture is also reported. The power law dependence of the attenuation coefficient is shown to vary across the measured frequency range. This is due to the varying frequency dependence of the different mechanisms responsible for the attenuation. The attenuation coefficient measured at high frequencies is found to be significantly higher than that predicted by historical power law parameters. A review of the attenuation mechanisms in blood along with previously reported experimental measurements is given. Values for the sound speed and density in the tested samples are also presented. Copyright © 2011 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.

  15. Reductions in red blood cell 2,3-diphosphoglycerate concentration during continuous renal replacment therapy.

    Science.gov (United States)

    Sharma, Shilpa; Brugnara, Carlo; Betensky, Rebecca A; Waikar, Sushrut S

    2015-01-07

    Hypophosphatemia is a frequent complication during continuous renal replacement therapy (CRRT), a dialytic technique used to treat AKI in critically ill patients. This study sought to confirm that phosphate depletion during CRRT may decrease red blood cell (RBC) concentration of 2,3-diphosphoglycerate (2,3-DPG), a crucial allosteric effector of hemoglobin's (Hgb's) affinity for oxygen, thereby leading to impaired oxygen delivery to peripheral tissues. Phosphate mass balance studies were performed in 20 patients with severe AKI through collection of CRRT effluent. RBC concentrations of 2,3-DPG, venous blood gas pH, and oxygen partial pressure required for 50% hemoglobin saturation (P50) were measured at CRRT initiation and days 2, 4, and 7. Similar measurements were obtained on days 0 and 2 in a reference group of 10 postsurgical patients, most of whom did not have AKI. Associations of 2,3-DPG with laboratory parameters and clinical outcomes were examined using mixed-effects and Cox regression models. Mean 2,3-DPG levels decreased from a mean (±SD) of 13.4±3.4 µmol/g Hgb to 11.0±3.1 µmol/g Hgb after 2 days of CRRT (Plevels decreased from 29.7±4.4 mmHg to 26.7±4.0 mmHg (Plevels after 2 days of CRRT were not significantly lower than those in the reference group on day 2. Among patients receiving CRRT, 2,3-DPG decreased by 0.53 µmol/g Hgb per 1 g phosphate removed (95% confidence interval 0.38 to 0.68 µmol/g Hgb; P<0.001). Greater reductions in 2,3-DPG were associated with higher risk for death (hazard ratio, 1.43; 95% confidence interval, 1.09 to 1.88; P=0.01). CRRT-induced phosphate depletion is associated with measurable reductions in RBC 2,3-DPG concentration and a shift in the O2:Hgb affinity curve even in the absence of overt hypophosphatemia. 2,3-DPG reductions may be associated with higher risk for in-hospital death and represent a potentially avoidable complication of CRRT. Copyright © 2015 by the American Society of Nephrology.

  16. Essential and toxic element concentrations in blood and urine and their associations with diet: results from a Norwegian population study including high-consumers of seafood and game.

    Science.gov (United States)

    Birgisdottir, B E; Knutsen, H K; Haugen, M; Gjelstad, I M; Jenssen, M T S; Ellingsen, D G; Thomassen, Y; Alexander, J; Meltzer, H M; Brantsæter, A L

    2013-10-01

    The first aim of the study was to evaluate calculated dietary intake and concentrations measured in blood or urine of essential and toxic elements in relation to nutritional and toxicological reference values. The second aim was to identify patterns of the element concentrations in blood and urine and to identify possible dietary determinants of the concentrations of these elements. Adults with a known high consumption of environmental contaminants (n=111), and a random sample of controls (n=76) answered a validated food frequency questionnaire (FFQ). Complete data on biological measures were available for 179 individuals. Blood and urine samples were analyzed for selenium, iodine, arsenic, mercury, cadmium and lead. Principal component analysis was used to identify underlying patterns of correlated blood and urine concentrations. The calculated intakes of selenium, iodine, inorganic arsenic and mercury were within guideline levels. For cadmium 24% of the high consumer group and 8% of the control group had intakes above the tolerable weekly intake. Concentrations of lead in blood exceeded the bench-mark dose lower confidence limits for some participants. However, overall, the examined exposures did not give rise to nutritional or toxicological concerns. Game consumption was associated with lead in blood (B(ln) 0.021; 95%CI:0.010, 0.031) and wine consumption. Seafood consumption was associated with urinary cadmium in non-smokers (B(ln) 0.009; 95%CI:0.003, 0.015). A novel finding was a distinct pattern of positively associated biological markers, comprising iodine, selenium, arsenic and mercury (eigenvalue 3.8), reflecting seafood intake (B 0.007; 95%CI:0.004, 0.010). The study clearly demonstrates the significance of seafood as a source of both essential nutrients and toxic elements simultaneously and shows that exposure to various essential and toxic elements can be intertwined. © 2013 Elsevier B.V. All rights reserved.

  17. Our experience of blood flow measurements using radioactive tracers

    International Nuclear Information System (INIS)

    Danet, Bernard.

    1974-01-01

    A critical study of blood flow measuring methods is proposed. After a review of the various diffusible and non-diffusible radioactive tracers and the corresponding detector systems, the principles which allow to measure blood flow from the data so obtained, are studied. There is a different principle of flow measurement for each type of tracer. The theory of flow measurement using non-diffusible tracers (human serum albumin labelled with 131 I or sup(99m)Tc, 113 In-labelled siderophiline) and its application to cardiac flow measurement are described first. Then the theory of flow measurement using diffusible tracers ( 133 Xe, 85 Kr) and its application to measurement of blood flow through tissues (muscles and kidney particularly) are described. A personal experience of this various flow measurements is reported. The results obtained, the difficulties encountered and the improvments proposed are developed [fr

  18. Testicular Cell Indices and Peripheral Blood Testosterone Concentrations in Relation to Age and Semen Quality in Crossbred (Holstein Friesian×Tharparkar Bulls

    Directory of Open Access Journals (Sweden)

    S. K. Rajak

    2014-11-01

    Full Text Available Present study analyzed the changes in peripheral blood testosterone concentrations and testicular cytogram in relation to age and semen quality in crossbred males. Three different age groups of crossbred males viz. bull calves (6 months, n = 5, young bulls (15 months, n = 5 and adult bulls (4 to 6 years, n = 8 were utilized for the study. Testicular fine needle aspiration cytology technique was used to quantify testicular cytology and their indices. Peripheral blood testosterone concentrations were measured using enzyme-linked immunosorbent assay method. Semen samples collected from adult bulls were microscopically evaluated for quality parameters. Mean peripheral blood testosterone concentrations in bull calves, young bulls and adult bulls were 2.28±0.09 ng/mL, 1.42±0.22 ng/mL and 5.66±1.08 ng/mL respectively, and that in adult bulls were significantly different (p<0.01 from young bulls and bull calves. There was no significant difference between the proportion of different testicular cells in bull calves and young bulls. Between young and adult bulls, significant differences (p<0.01 were observed in the proportion of spermatocytes, spermatozoa, and sperm: Sertoli cell ratio. The proportions of Sertoli cells showed a significant difference (p<0.01 between the three age groups. The number of primary spermatocytes had a positive correlation with peripheral blood testosterone concentrations in bull calves (r = 0.719, p<0.01. Number of Sertoli cells per 100 germ cells was negatively correlated with blood testosterone concentration in young bulls (r = −0.713, p<0.01. Among different semen parameters in adult bulls, ejaculate volume (r = 0.790, p<0.05 had positive relationship, and sperm motility had significant negative correlation (r = −0.711, p<0.05 with testosterone concentrations. The number of Sertoli cells and Sertoli cell index had a positive correlation with various semen quality parameters (p<0.001. Results of the present study

  19. The Effects of Feeding Raw Fiber Concentrate on Growth Performance and Blood Metabolites of Suckling Holstein Calves

    OpenAIRE

    Mehdi Dehghan-Banadaky; Fridoon Niazi; Mohsen Ghiasvand

    2012-01-01

    Sixteen female Holstein calves allocated in three treatments including: 1: control, 2: fed raw fiber concentrate (RFC) for 45 days and 3: fed RFC for 90 days. RFC supplement (Vitacel® 200) was added to milk immediately before feeding (10 g/L milk). Withers height and body weights of calves were measured monthly. Individual dry matter intake was recorded daily. Blood samples were taken monthly. The result showed that calves consumed RFC had significantly greater weaning an...

  20. Serial alterations in digital hemodynamics and endothelin-1 immunoreactivity, platelet-neutrophil aggregation, and concentrations of nitric oxide, insulin, and glucose in blood obtained from horses following carbohydrate overload.

    Science.gov (United States)

    Eades, Susan C; Stokes, Ashley M; Johnson, Philip J; LeBlanc, Casey J; Ganjam, Venkataseshu K; Buff, Preston R; Moore, Rustin M

    2007-01-01

    To quantify changes in endothelium-derived factors and relate those changes to various aspects of digital hemodynamics during the prodromal stages of carbohydrate overload (CHO)-induced laminitis in horses. 20 adult horses without abnormalities of the digit. Digital and jugular venous blood samples were collected at 1-hour intervals (for assessment of endothelin-1 [ET-1] immunoreactivity and measurement of glucose, insulin, and nitric oxide [NO] concentrations) or 4-hour intervals (CBC and platelet-neutrophil aggregate assessment) for 8 hours or 16 hours after induction of CHO-associated laminitis in horses treated with an ET-1 antagonist. Effects of treatment, collection site, and time and the random effects of horse on each variable were analyzed by use of a repeated-measures model. Where treatment and collection site had no significant effect, data were combined. Compared with baseline values, CHO resulted in changes in several variables, including a significant increase from baseline in digital blood ET-like immunoreactivity at 11 hours; digital blood ET-like immunoreactivity was significantly greater than that in jugular venous blood at 8, 9, 11, and 12 hours. Digital and jugular venous blood concentrations of glucose increased from baseline significantly at 3, 4, and 5 hours; insulin concentration increased significantly at 5 hours; and the number of platelet-neutrophil aggregates increased significantly at 12 hours. In horses, concurrent increases in venous blood ET-1 immunoreactivity, insulin and glucose concentrations, and platelet-neutrophil aggregates support a role of endothelial dysfunction in the pathogenesis of CHO-induced laminitis.

  1. The optimal scheme of self blood pressure measurement as determined from ambulatory blood pressure recordings

    NARCIS (Netherlands)

    Verberk, Willem J.; Kroon, Abraham A.; Kessels, Alfons G. H.; Lenders, Jacques W. M.; Thien, Theo; van Montfrans, Gert A.; Smit, Andries J.; de Leeuw, Peter W.

    Objective To determine how many self-measurements of blood pressure (BP) should be taken at home in order to obtain a reliable estimate of a patient's BP. Design Participants performed self blood pressure measurement (SBPM) for 7 days (triplicate morning and evening readings). In all of them, office

  2. [Influence of an infusion of 5- or 20% glucose solution on blood glucose and inorganic phosphate concentrations in dairy cows].

    Science.gov (United States)

    Aldaek, T A A; Failing, K; Wehrend, A; Klymiuk, M C

    2011-01-01

    The study was performed to evaluate the influence of an intravenous infusion of 5% and 20% dextrose solution on the plasma concentration of glucose and inorganic phosphate in healthy, dairy cows. Ten healthy, lactating, nonpregnant 3 to 6 year-old Holstein-Friesian cows were included in this investigation. The daily milk yield was 20.3±2.7 liters. Blood plasma concentrations of inorganic phosphate and glucose were determined before, during, immediately and 60 minutes after infusion of 0.9% physiological saline, 5% or 20% dextrose solution. A statistically significant influence of dextrose infusion on blood glucose concentration was observed. After 20% dextrose infusion (200 g dextrose) the blood glucose concentration increased by approximately 13.26 mmol/l. The administration of 5% dextrose solution (50 g dextrose) yielded an increase of blood glucose concentration by 3.31 mmol/l. There was no significant correlation between plasma inorganic phosphate concentrations and infusion of 0.9% saline, 5% or 20% dextrose solution. Intravenous administration of 1000 ml of 5% or 20% dextrose solution does not induce a lasting plasma phosphate reduction and is suitable for elevating the blood glucose concentration.

  3. Concentrations of ions in blood or athletes using NAA

    International Nuclear Information System (INIS)

    Kovacs, Luciana; Zamboni, Cibele B.; Loureno, Thiago F.; Nunes, Lazaro A.S.; Macedo, Denise V.

    2011-01-01

    Sodium (Na), chlorine (Cl) and potassium (K) are widely distributed in the body and are the mainly of body fluids electrolytes. K is the major intracellular ion. Na and Cl are the major extracellular ions. Therefore, Na and Cl can be regarded as the most important osmotically active electrolytes. The concentrations of these ions in body fluids are very tightly controlled. These electrolytes play central roles in electrolytic balances and current, in osmotic control, in the transport of organic metabolites by cells, and stabilization of poly electrolytes in cells. In this study Na, Cl and K levels were investigated in blood of athletes submitted to physical exercise at Laboratorio de Bioquimica do Exercicio (LABEX/UNICAMP - Brazil) using Neutron Activation Analyses (NAA) technique. The blood samples were collected from six male athletes, ranging from 18 to 26 years old, before and after the physical training. These results were compared with the rest condition (before start the physical exercise), as well as with the control group (subjects of same age but not involved with physical activities), for checking the performance of the athletes during and after the exercise. The nuclear procedure adopted as NAA, it can be an alternative procedure to perform biochemistry analyses in blood, mainly when the biological material is scarce. (author)

  4. Multicentre standardisation of a clinical grade procedure for the preparation of allogeneic platelet concentrates from umbilical cord blood

    Science.gov (United States)

    Rebulla, Paolo; Pupella, Simonetta; Santodirocco, Michele; Greppi, Noemi; Villanova, Ida; Buzzi, Marina; De Fazio, Nicola; Grazzini, Giuliano

    2016-01-01

    Background In addition to a largely prevalent use for bleeding prophylaxis, platelet concentrates from adult blood have also been used for many years to prepare platelet gels for the repair of topical skin ulcers. Platelet gel can be obtained by activation of fresh, cryopreserved, autologous or allogeneic platelet concentrates with calcium gluconate, thrombin and/or batroxobin. The high content of tissue regenerative factors in cord blood platelets and the widespread availability of allogeneic cord blood units generously donated for haematopoietic transplant but unsuitable for this use solely because of low haematopoietic stem cell content prompted us to develop a national programme to standardise the production of allogeneic cryopreserved cord blood platelet concentrates (CBPC) suitable for later preparation of clinical-grade cord blood platelet gel. Materials and methods Cord blood units collected at public banks with total nucleated cell counts 150×109/L and volume >50 mL, underwent soft centrifugation within 48 hours of collection. Platelet-rich plasma was centrifuged at high speed to obtain a CBPC with target platelet concentration of 800–1,200×109/L, which was cryopreserved, without cryoprotectant, below −40 °C. Results During 14 months, 13 banks produced 1,080 CBPC with mean (± standard deviation) volume of 11.4±4.4 mL and platelet concentration of 1,003±229×109/L. Total platelet count per CBPC was 11.3±4.9×109. Platelet recovery from cord blood was 47.7±17.8%. About one-third of cord blood units donated for haematopoietic transplant could meet the requirements for preparation of CBPC. The cost of preparation was € 160.92/CBPC. About 2 hours were needed for one technician to prepare four CBPC. Discussion This study yielded valuable scientific and operational information regarding the development of clinical trials using allogeneic CBPC. PMID:26509822

  5. Risk analysis and detection of thrombosis by measurement of electrical resistivity of blood.

    Science.gov (United States)

    Sapkota, Achyut; Asakura, Yuta; Maruyama, Osamu; Kosaka, Ryo; Yamane, Takashi; Takei, Masahiro

    2013-01-01

    Monitoring of thrombogenic process is very important in ventricular assistance devices (VADs) used as temporary or permanent measures in patients with advanced heart failure. Currently, there is a lack of a system which can perform a real-time monitoring of thrombogenic activity. Electrical signals vary according to the change in concentration of coagulation factors as well as the distribution of blood cells, and thus have potential to detect the thrombogenic process in an early stage. In the present work, we have made an assessment of an instrumentation system exploiting the electrical properties of blood. The experiments were conducted using bovine blood. Electrical resistance tomography with eight-electrode sensor was used to monitor the spatio-temporal change in electrical resistivity of blood in thrombogenic and non-thrombogenic condition. Under non-thrombogenic condition, the resistivity was uniform across the cross-section and average resistivity monotonically decreased with time before remaining almost flat. In contrary, under thrombogenic condition, there was non-uniform distribution across the cross-section, and average resistivity fluctuated with time.

  6. The relative nutritive value of irradiated spray-dried blood powder and heat-sterilized blood meal as measured in combination with whey protein

    International Nuclear Information System (INIS)

    Downes, T.E.H.; Nourse, L.D.; Siebrits, F.K.; Hastings, J.W.

    1987-01-01

    A method of processing blood meal in which nutritive value of the protein is preserved is described, since appreciable losses occur in the nutritive value of the protein when prepared by heat sterilization with drying at atmospheric pressure in steam jacketed vessels. Blood was spray dried and irradiated at an intensity of 10 kGy. Collectively the heat of spray drying and irradiation was effective in killing both the virus plaque-forming units and the bacteria, thus producing a commercially acceptable sterile product of higher nutritive value. The relative nutritive values (RNV) of 50:50 protein were 0,56 for whey protein concentrate plus heat-sterilized blood meal and 0.90 for whey protein concentrate plus irradiated spray-dried blood powder. Whey protein concentrate used as a control has a RNV of 1,0

  7. Smartphone-based Continuous Blood Pressure Measurement Using Pulse Transit Time.

    Science.gov (United States)

    Gholamhosseini, Hamid; Meintjes, Andries; Baig, Mirza; Linden, Maria

    2016-01-01

    The increasing availability of low cost and easy to use personalized medical monitoring devices has opened the door for new and innovative methods of health monitoring to emerge. Cuff-less and continuous methods of measuring blood pressure are particularly attractive as blood pressure is one of the most important measurements of long term cardiovascular health. Current methods of noninvasive blood pressure measurement are based on inflation and deflation of a cuff with some effects on arteries where blood pressure is being measured. This inflation can also cause patient discomfort and alter the measurement results. In this work, a mobile application was developed to collate the PhotoPlethysmoGramm (PPG) waveform provided by a pulse oximeter and the electrocardiogram (ECG) for calculating the pulse transit time. This information is then indirectly related to the user's systolic blood pressure. The developed application successfully connects to the PPG and ECG monitoring devices using Bluetooth wireless connection and stores the data onto an online server. The pulse transit time is estimated in real time and the user's systolic blood pressure can be estimated after the system has been calibrated. The synchronization between the two devices was found to pose a challenge to this method of continuous blood pressure monitoring. However, the implemented continuous blood pressure monitoring system effectively serves as a proof of concept. This combined with the massive benefits that an accurate and robust continuous blood pressure monitoring system would provide indicates that it is certainly worthwhile to further develop this system.

  8. The use of Fourier-transform infrared spectroscopy for the quantitative determination of glucose concentration in whole blood

    International Nuclear Information System (INIS)

    Shen, Y C; Davies, A G; Linfield, E H; Elsey, T S; Taday, P F; Arnone, D D

    2003-01-01

    Fourier-transform infrared transmission spectroscopy has been used for the determination of glucose concentration in whole blood samples from 28 patients. A 4-vector partial least-squares calibration model, using the spectral range 950-1200 cm -1 , yielded a standard-error-of-prediction of 0.59 mM for an independent test set. For blood samples from a single patient, we found that the glucose concentration was proportional to the difference between the values of the second derivative spectrum at 1082 cm -1 and 1093 cm -1 . This indicates that spectroscopy at these two specific wavenumbers alone could be used to determine the glucose concentration in blood plasma samples from a single patient, with a prediction error of 0.95 mM

  9. Noninvasive measurement of postocclusive parameters in human forearm blood by near infrared spectroscopy

    Science.gov (United States)

    Rao, K. Prahlad; Radhakrishnan, S.; Reddy, M. Ramasubba

    2005-04-01

    Near infrared (NIR) light in the wavelength range from 700 to 900 nm can pass through skin, bone and other tissues relatively easily. As a result, NIR techniques allow a noninvasive assessment of hemoglobin saturation for a wide range of applications, such as in the study of muscle metabolism, the diagnosis of vascular disorders, brain imaging, and breast cancer detection. Near infrared Spectroscopy (NIRS) is an effective tool to measure the hemoglobin concentration in the tissues, which can discriminate optically the oxy- and deoxy- hemoglobin species because of their different near-infrared absorption spectra. We have developed an NIRS probe consisting of a laser diode of 830 nm wavelength and a PIN photodiode in reflectance mode. We have selected a set of healthy volunteers (mean age 30, range 26-40 years) for the study. The probe is placed on forearm of each subject and the backscattered light intensity is measured by occluding the blood flow at 210, 110 and 85 mmHg pressures. Recovery time, peak time and time after 50% release of the cuff pressure are determined from the optical densities during the post occlusive state of forearm. These parameters are useful for determining the transient increase in blood flow after the release of blood occlusion. Clinically, the functional aspects of blood flow in the limbs could be evaluated noninvasively by NIRS.

  10. Blood harmane, blood lead, and severity of hand tremor: evidence of additive effects.

    Science.gov (United States)

    Louis, Elan D; Factor-Litvak, Pam; Gerbin, Marina; Slavkovich, Vesna; Graziano, Joseph H; Jiang, Wendy; Zheng, Wei

    2011-03-01

    Tremor is a widespread phenomenon in human populations. Environmental factors are likely to play an etiological role. Harmane (1-methyl-9H-pyrido[3,4-β]indole) is a potent tremor-producing β-carboline alkaloid. Lead is another tremor-producing neurotoxicant. The effects of harmane and lead with respect to tremor have been studied in isolation. We tested the hypothesis that tremor would be particularly severe among individuals who had high blood concentrations of both of these toxicants. Blood concentrations of harmane and lead were each quantified in 257 individuals (106 essential tremor cases and 151 controls) enrolled in an environmental epidemiological study. Total tremor score (range = 0-36) was a clinical measure of tremor severity. The total tremor score ranged from 0 to 36, indicating that a full spectrum of tremor severities was captured in our sample. Blood harmane concentration correlated with total tremor score (p = 0.007), as did blood lead concentration (p = 0.045). The total tremor score was lowest in participants with both low blood harmane and lead concentrations (8.4 ± 8.2), intermediate in participants with high concentrations of either toxicant (10.5 ± 9.8), and highest in participants with high concentrations of both toxicants (13.7 ± 10.4) (p=0.01). Blood harmane and lead concentrations separately correlated with total tremor scores. Participants with high blood concentrations of both toxicants had the highest tremor scores, suggesting an additive effect of these toxicants on tremor severity. Given the very high population prevalence of tremor disorders, identifying environmental determinants is important for primary disease prevention. Copyright © 2010 Elsevier Inc. All rights reserved.

  11. Challenges in standardization of blood pressure measurement at the population level.

    Science.gov (United States)

    Tolonen, Hanna; Koponen, Päivikki; Naska, Androniki; Männistö, Satu; Broda, Grazyna; Palosaari, Tarja; Kuulasmaa, Kari

    2015-04-10

    Accurate blood pressure measurements are needed in clinical practice, intervention studies and health examination surveys. Blood pressure measurements are sensitive: their accuracy can be affected by measurement environment, behaviour of the subject, measurement procedures, devices used for the measurement and the observer. To minimize errors in blood pressure measurement, a standardized measurement protocol is needed. The European Health Examination Survey (EHES) Pilot project was conducted in 2009-2012. A pilot health examination survey was conducted in 12 countries using a standardized protocol. The measurement protocols used in each survey, training provided for the measurers, measurement data, and observations during site visits were collected and evaluated to assess the level of standardization. The EHES measurement protocol for blood pressure was followed accurately in all 12 pilot surveys. Most of the surveys succeeded in organizing a quiet and comfortable measurement environment, and staff instructed survey participants appropriately before examination visits. In all surveys, blood pressure was measured three times, from the right arm in a sitting posture. The biggest variation was in the device used for the blood pressure measurement. It is possible to reach a high level of standardization for blood pressure measurements across countries and over time. A detailed, standardized measurement protocol, and adequate training and monitoring during the fieldwork and centrally organized quality assessment of the data are needed. The recent EU regulation banning the sale of mercury sphygmomanometer in European Union Member States has set new challenges for the standardization of measurement devices since the validity of oscillometric measurements is device-specific and performance of aneroid devices depends very much on calibration.

  12. Continuous measurements of outdoor radon concentrations

    International Nuclear Information System (INIS)

    Iida, T.; Ikebe, Y.; Suzuki, K.; Ueno, K.; Komura, K.; Kato, I.; Jin Yihe

    1993-01-01

    The authors studied and developed an electrostatic 222 Rn monitor and have measured continuously outdoor radon ( 222 Rn) concentrations at Nagoya University since 1985. Four 222 Rn monitors were newly constructed to measure outdoor 222 Rn concentrations at other locations. The 222 Rn concentrations at Nagoya and Kasugai show a clear diurnal variation in autumn, and a seasonal pattern of a spring-summer minimum and a autumn-winter maximum. The results at Toki are the same pattern as that at Nagoya except spring. The concentrations at Kanazawa show a slight seasonal variation. A clear diurnal variation is observed in summer. (4 figs.)

  13. Automatic noninvasive measurement of systolic blood pressure using photoplethysmography

    Directory of Open Access Journals (Sweden)

    Glik Zehava

    2009-10-01

    Full Text Available Abstract Background Automatic measurement of arterial blood pressure is important, but the available commercial automatic blood pressure meters, mostly based on oscillometry, are of low accuracy. Methods In this study, we present a cuff-based technique for automatic measurement of systolic blood pressure, based on photoplethysmographic signals measured simultaneously in fingers of both hands. After inflating the pressure cuff to a level above systolic blood pressure in a relatively slow rate, it is slowly deflated. The cuff pressure for which the photoplethysmographic signal reappeared during the deflation of the pressure-cuff was taken as the systolic blood pressure. The algorithm for the detection of the photoplethysmographic signal involves: (1 determination of the time-segments in which the photoplethysmographic signal distal to the cuff is expected to appear, utilizing the photoplethysmographic signal in the free hand, and (2 discrimination between random fluctuations and photoplethysmographic pattern. The detected pulses in the time-segments were identified as photoplethysmographic pulses if they met two criteria, based on the pulse waveform and on the correlation between the signal in each segment and the signal in the two neighboring segments. Results Comparison of the photoplethysmographic-based automatic technique to sphygmomanometry, the reference standard, shows that the standard deviation of their differences was 3.7 mmHg. For subjects with systolic blood pressure above 130 mmHg the standard deviation was even lower, 2.9 mmHg. These values are much lower than the 8 mmHg value imposed by AAMI standard for automatic blood pressure meters. Conclusion The photoplethysmographic-based technique for automatic measurement of systolic blood pressure, and the algorithm which was presented in this study, seems to be accurate.

  14. Blood metals concentration in type 1 and type 2 diabetics.

    Science.gov (United States)

    Forte, Giovanni; Bocca, Beatrice; Peruzzu, Angela; Tolu, Francesco; Asara, Yolande; Farace, Cristiano; Oggiano, Riccardo; Madeddu, Roberto

    2013-12-01

    Mechanisms for the onset of diabetes and the development of diabetic complications remain under extensive investigations. One of these mechanisms is abnormal homeostasis of metals, as either deficiency or excess of metals, can contribute to certain diabetic outcomes. Therefore, this paper will report the blood levels of chromium (Cr), copper (Cu), iron (Fe), manganese (Mn), mercury (Hg), nickel (Ni), lead (Pb), selenium (Se), and zinc (Zn) in subjects with type 1 diabetes (n = 192, mean age 48.8 years, mean disease duration 20.6 years), type 2 diabetes (n = 68, mean age 68.4 years, mean disease duration 10.2 years), and in control subjects (n = 59, mean age 57.2 years), and discuss the results indicating their possible role in diabetes. The metal concentrations were measured by sector field inductively coupled plasma mass spectrometry after microwave-induced acid digestion of blood samples. The accuracy was checked using a blood-based certified reference material, and recoveries of all elements were in the range of 92-101 % of certified values. Type 1 diabetes was found to be associated with Cr (p = 0.02), Mn (p < 0.001), Ni (p < 0.001), Pb (p = 0.02), and Zn (p < 0.001) deficiency, and type 2 diabetes with Cr (p = 0.014), Mn (p < 0.001), and Ni (p < 0.001) deficiency. These deficiencies were appreciated also subdividing the understudied patients for gender and age groups. Furthermore, in type 1 diabetes, there was a positive correlation between Pb and age (p < 0.001, ρ = 0.400) and Pb and BMI (p < 0.001, ρ = 0.309), while a negative correlation between Fe and age (p = 0.002, ρ = -0.218). In type 2 diabetes, there was a negative correlation between Fe and age (p = 0.017, ρ = -0.294) and Fe and BMI (p = 0.026, ρ = -0.301). Thus, these elements may play a role in both forms of diabetes and combined mineral supplementations could have beneficial effects.

  15. Low Red Blood Cell Vitamin C Concentrations Induce Red Blood Cell Fragility: A Link to Diabetes Via Glucose, Glucose Transporters, and Dehydroascorbic Acid

    Directory of Open Access Journals (Sweden)

    Hongbin Tu

    2015-11-01

    Full Text Available Strategies to prevent diabetic microvascular angiopathy focus on the vascular endothelium. Because red blood cells (RBCs are less deformable in diabetes, we explored an original concept linking decreased RBC deformability to RBC ascorbate and hyperglycemia. We characterized ascorbate concentrations from human and mouse RBCs and plasma, and showed an inverse relationship between RBC ascorbate concentrations and deformability, measured by osmotic fragility. RBCs from ascorbate deficient mice were osmotically sensitive, appeared as spherocytes, and had decreased β-spectrin. These aberrancies reversed with ascorbate repletion in vivo. Under physiologic conditions, only ascorbate's oxidation product dehydroascorbic acid (DHA, a substrate for facilitated glucose transporters, was transported into mouse and human RBCs, with immediate intracellular reduction to ascorbate. In vitro, glucose inhibited entry of physiologic concentrations of dehydroascorbic acid into mouse and human RBCs. In vivo, plasma glucose concentrations in normal and diabetic mice and humans were inversely related to respective RBC ascorbate concentrations, as was osmotic fragility. Human RBC β-spectrin declined as diabetes worsened. Taken together, hyperglycemia in diabetes produced lower RBC ascorbate with increased RBC rigidity, a candidate to drive microvascular angiopathy. Because glucose transporter expression, DHA transport, and its inhibition by glucose differed for mouse versus human RBCs, human experimentation is indicated.

  16. Whole body [O-15]water pharmacokinetics measured in blood

    NARCIS (Netherlands)

    Maguire, RP; Spyrou, NM; Leenders, KL

    A simple pharmacokinetic model to explain the time course of [0-15]water in human whole blood after bolus injection is described. The model has been derived from measurements in twelve healthy volunteers who were measured repeatedly, resulting in 67 datasets, made in the context of PET blood flow

  17. Variation in heart rate and blood lactate concentration in freestyle kytesurfing.

    Science.gov (United States)

    Camps, A; Vercruyssen, F; Brisswalter, J

    2011-06-01

    The aim of this paper was to evaluate the physiological demands of freestyle kitesurfing. Ten elite subjects performed an incremental running test on a treadmill and a three 7 min simulated freestyle heats of kitesurfing in MW (Midwind) condition ranging from 15 to 22 knots. Oxygen uptake (VO(2)) was estimated from the heart rate (HR) recorded during the freestyle trial using the individual HR-VO(2) relationship determined during the incremental test. Blood lactate concentration [Lab] was measured at rest and 3 min after the exercise completion. 3 experienced kitesurfers acted as judges to better simulate competition conditions. Linear relationship was demonstrated between scores and % HR(max) on water (r=-0.764, Pat the end of crossing trial (5.2±0.8 mmol L(-1)). This first analysis of freestyle kitesurfing suggests that the energy demand is sustained by both aerobic and anaerobic metabolism during a MW condition and freestyle event of kitesurfing.

  18. Determining lead concentration in the blood of primary school children in Damascus city and suburbs

    International Nuclear Information System (INIS)

    Al-Merey, R.; Al-Ghali, M.; Mortada, S.

    2006-01-01

    Due to the fact that lead is a relatively common element in nature and one of the most pollutant elements which man kind is exposed to in densely populated cities that have a large number of vehicles using leaded petrol which has bad effects on human health particularly children, it is found necessary to scan the health situation related to lead exposure in Damascus. The present work focuses on determining the concentration of lead in the blood of primary school children in Damascus city and some schools in the suburbs of Damascus. 546 blood samples were collected from school children in Damascus city and 183 blood samples from school children in the suburbs of Damascus. Parameters such as student's environmental, social and behavioral information were taken into consideration and correlate with lead concentration in students blood samples. Results showed that 76.3% of the samples have more than 10 μg/100 ml of lead in the blood. Which has lead to the following health effects: Decrease in hemoglobin and vitamin-D, Effects on central nervous system, Deterioration in children growth, decreasing in IQ, and kidney failure. (Authors)

  19. Determining lead concentration in the blood of primary school children in Damascus city and suburbs

    International Nuclear Information System (INIS)

    Al-Merey, R.; Galee, M.; Mortada, S.

    2005-05-01

    Due to the fact that lead is a relatively common element in nature and one of the most pollutant elements which man kind is exposed to in densely populated cities that have a large number of vehicles using leaded petrol which has bad effects on human health particularly children, it is found necessary to scan the health situation related to lead exposure in Damascus. The present work focuses on determining the concentration of lead in the blood of primary school children in Damascus city and some schools in the suburbs of Damascus. 546 blood samples were collected from school children in Damascus city and 183 blood samples from school children in the suburbs of Damascus. Parameters such as student's environmental, social and behavioral information were taken into consideration and correlate with lead concentration in students blood samples. Results showed that 76.3% of the samples have more than 10 μg/100 ml of lead in the blood. Which has lead to the following health effects: Decrease in hemoglobin and vitamin-D, Effects on central nervous system, Deterioration in children growth, decreasing in IQ, and kidney failure. (Authors)

  20. Detection of haemoglobins with abnormal oxygen affinity by single blood gas analysis and 2,3-diphosphoglycerate measurement.

    Science.gov (United States)

    Guerrini, G; Morabito, A; Samaja, M

    2000-10-01

    The aim is to determine if a single measurement of blood 2,3-diphosphoglycerate combined with gas analysis (pH, PCO2, PO2 and saturation) can identify the cause of an altered blood-oxygen affinity: the presence of an abnormal haemoglobin or a red cell disorder. The population (n=94) was divided into healthy controls (A, n=14), carriers of red cell disorders (B, n=72) and carriers of high oxygen affinity haemoglobins (C, n=8). Those variables were measured both in samples equilibrated at selected PCO2 and PO2 and in venous blood. In the univariable approach applied to equilibrated samples, we correctly identified C subjects in 93.6% or 96.8% of the cases depending on the selected variable, the standard P50 (PO2 at which 50% of haemoglobin is oxygenated) or a composite variable calculated from the above measurements. After introducing the haemoglobin concentration as a further discriminating variable, the A and B subjects were correctly identified in 91.9% or 94.2% of the cases, respectively. These figures become 93.0% or 86.1%, and 93.7% or 94.9% of the cases when using direct readings from venous blood, thereby avoiding the blood equilibration step. This test is feasible also in blood samples stored at 4 degrees C for 48 h, or at room temperature for 8 h.

  1. A 125I-radioimmunoassay for measuring androstenedione in serum and in blood-spot samples from neonates

    International Nuclear Information System (INIS)

    Thomson, S.; Wallace, A.M.; Cook, B.

    1989-01-01

    We developed a radioimmunoassay with a gamma-emitting radioligand to measure androstenedione in human serum and in dried blood-spot samples from newborns. Antisera were raised in rabbits against androstenedione linked to bovine serum albumin at positions 3, 6, or 11 on the steroid nucleus. Radioligands were prepared by linking [ 125 I]iodohistamine at positions 3, 6, or 11. Linkages were through either carboxymethyloxime or hemisuccinate bridges. All label and antibody combinations were examined, and the most sensitive and specific combination (antiserum raised against androstenedione-3-carboxymethyloxime-bovine serum albumin with an androstenedione-carboxymethyloxime-[ 125 I]iodohistamine label) was selected for full evaluation. We report the performance of these selected reagents in an immunoassay for androstenedione in both serum and dried blood-spot samples from neonates. We measured concentrations of androstenedione in serum under normal and pathological conditions such as congenital adrenal hyperplasia and polycystic ovarian disease. Diurnal variation in normal men was observed. Androstenedione was measured in blood spots from neonates born at term or prematurely, with respiratory distress syndrome, or with congenital adrenal hyperplasia

  2. Higher blood harmane (1-methyl-9H-pyrido[3,4-b]indole) concentrations correlate with lower olfactory scores in essential tremor.

    Science.gov (United States)

    Louis, Elan D; Rios, Eileen; Pellegrino, Kathryn M; Jiang, Wendy; Factor-Litvak, Pam; Zheng, Wei

    2008-05-01

    Harmane (1-methyl-9H-pyrido[3,4-b]indole), a neurotoxin, may be an environmental risk factor for essential tremor (ET). Harmane and related chemicals are toxic to the cerebellum. Whether it is through this mechanism (cerebellar toxicity) that harmane leads to ET is unknown. Impaired olfaction may be a feature of cerebellar disease. To determine whether blood harmane concentrations correlate with olfactory test scores in patients with ET. Blood harmane concentrations were quantified using high performance liquid chromatography. Odor identification testing was performed with the University of Pennsylvania Smell Identification Test (UPSIT). In 83 ET cases, higher log blood harmane concentration was correlated with lower UPSIT score (rho=-0.46, p<0.001). 25/40 (62.5%) cases with high log blood harmane concentration (based on a median split) had low UPSIT scores (based on a median split) vs. 12/43 (27.9%) ET cases with low log blood harmane concentration (adjusted odd ratios (OR) 4.04, 95% confidence intervals (CI) 1.42-11.50, p=0.009). When compared with the low log blood harmane tertile, the odds of olfactory dysfunction were 2.64 times higher in cases in the middle tertile and 10.95 times higher in cases in the high tertile. In 69 control subjects, higher log blood harmane concentration was not correlated with lower UPSIT score (rho=0.12, p=0.32). Blood harmane concentrations were correlated with UPSIT scores in ET cases but not controls. These analyses set the stage for postmortem studies to further explore the role of harmane as a cerebellar toxin in ET.

  3. Simultaneous determination of size and refractive index of red blood cells by light scattering measurements

    International Nuclear Information System (INIS)

    Ghosh, N.; Buddhiwant, P.; Uppal, A.; Majumder, S.K.; Patel, H.S.; Gupta, P.K.

    2006-01-01

    We present a fast and accurate approach for simultaneous determination of both the mean diameter and refractive index of a collection of red blood cells (RBCs). The approach uses the peak frequency of the power spectrum and the corresponding phase angle obtained by performing Fourier transform on the measured angular distribution of scattered light to determine these parameters. Results on the measurement of two important clinical parameters, the mean cell volume and mean cell hemoglobin concentration of a collection of RBCs, are presented

  4. Method comparison and validation of a prototype device for measurement of ionized calcium concentrations cow-side against a point-of-care instrument and a benchtop blood-gas analyzer reference method.

    Science.gov (United States)

    Neves, R C; Stokol, T; Bach, K D; McArt, J A A

    2018-02-01

    The objective of this study was to assess an optimized ion-selective electrode Ca-module prototype as a potential cow-side device for ionized Ca (iCa) measurements in bovine blood. A linearity experiment showed no deviation from linearity over a range of iCa concentrations compared with a commercial point-of-care (POC) device commonly used in the field (POC VS ; VetScan i-STAT, Abaxis North America, Union City, CA) and a laboratory gold standard benchtop blood-gas analyzer [reference analyzer (RA); ABL-800 FLEX, Radiometer Medical, Copenhagen, Denmark]. Coefficient of variation on 3 samples with high, within-range, and low iCa concentrations ranged from 1.0 to 3.9% for the prototype. A follow-up validation experiment was performed, in which our objectives were to (1) assess the performance of the prototype cow-side against the POC VS (farm gold-standard) using fresh non-anticoagulated whole-blood samples; (2) assess the performance of the prototype and the POC VS against the RA in a diagnostic laboratory using blood collected in a heparin-balanced syringe; and (3) assess the agreement of the prototype and POC VS on-farm (fresh non-anticoagulated whole blood) against the RA on heparin-balanced blood. Finally, sensitivity and specificity of the results obtained by the prototype and the POC VS cow-side compared with the results obtained by the laboratory RA using 3 different iCa cut points for classification of subclinical hypocalcemia were calculated. A total of 101 periparturient Holstein cows from 3 dairy farms in New York State were used for the second experiment. Ionized Ca results from the prototype cow-side were, on average, 0.06 mmol/L higher than the POC VS . With heparin-balanced samples under laboratory conditions, the prototype and POC VS measured an average 0.04 mmol/L higher and lower, respectively, compared with the RA. Results from the prototype and POC VS cow-side were 0.01 mmol/L higher and 0.05 mmol/L lower, respectively, compared with results from

  5. FK concentrator outdoor measurements

    OpenAIRE

    Hernández Sanz, Maikel; Vilaplana, J., J.; Benitez Gimenez, Pablo; Mohedano,, Rubén; Zamora Herranz, Pablo; Miñano Dominguez, Juan Carlos; Mendes Lopes, Joao

    2013-01-01

    The FK is a two-stage optical concentrator for CPV, composed by a Fresnel lens working as POE and a refractive element working as SOE. Both elements perform Köhler integration, for uniform irradiance purposes. The FK has demonstrated that compares very well with other Fresnel-based concentrator optics. Recent on-sun measurements carried out on an FK mono-module prototype have already shown outstanding results, achieving electrical efficiencies over 34%. Further optimization of optical design ...

  6. Measurements of natural 41Ca concentrations

    International Nuclear Information System (INIS)

    Steinhof, A.

    1989-05-01

    Atomic mass spectroscopic examinations on 41 Ca were carried out in the UNILAC accelerator. A sensitivity of about 10 -15 was achieved. This would allow the measurement of present natural 41 Ca concentrations as soon as the problem of the transmission determination is solved. In this respect suggestions were worked out and their feasibility discussed. The detection of 41 Ca-ions is especially free of background when high UNILAC-energies are applied. An estimation showed a background level corresponding with a 41 Ca concentration of less then 10 -17 referred to 40 Ca. Besides an independent concept for the electromagnetic concentration of 41 Ca with variable concentration factors was developed. After being concentrated up to 50 respectively 25 times the initial concentration in the GSI mass separator, the 41 Ca concentration of three recent deer bones found in the Odenwald was measured by atomic mass spectroscopy in the 14UD-Pelletron Tandem in Rehovot (Israel). The measured 41 Ca concentrations ranged between 10 -14 to 10 -13 with consideration of the concentration factor. A theoretical study of the 41 Ca production in the earth's surface based on cosmic radiation illustrates the influence of trace elements on the neutron flux and thus on the 41 Ca production. This influence might be a possible explanation for the observed amplitude of variation of the 41 Ca concentration in recent bones which are of decisive importance for the feasibility of 41 Ca-related dating. In this work a method is suggested that does not depend on the amplitude of variation mentioned above and which would allow the determination of the erosion rate of rocks by its 41 Ca concentrations. (orig./HP) [de

  7. Factors Related to Blood Hydroxychloroquine Concentration in Patients With Systemic Lupus Erythematosus.

    Science.gov (United States)

    Yeon Lee, Ji; Lee, Jennifer; Ki Kwok, Seung; Hyeon Ju, Ji; Su Park, Kyung; Park, Sung-Hwan

    2017-04-01

    To identify factors associated with blood concentrations of hydroxychloroquine (HCQ) and its major metabolite, N-desethylhydroxychloroquine (DHCQ), in patients with systemic lupus erythematosus (SLE; lupus) receiving long-term oral HCQ treatment. SLE patients who had been taking HCQ for more than 3 months were recruited. Various clinical characteristics, laboratory values, and SLE Disease Activity Index (SLEDAI) scores were examined. The concentrations of HCQ and DHCQ ([HCQ] and [DHCQ]) were measured by liquid chromatography mass spectrometry, and the relationship between [HCQ], [DHCQ], and [HCQ]:[DHCQ] ratio to various factors was investigated. In total, 189 SLE patients receiving long-term HCQ treatment were included in the analysis. The median (interquartile range [IQR]) [HCQ] was 515 (IQR 353-720) ng/ml, the median [DHCQ] was 417 (IQR 266-591) ng/ml, and the median [HCQ]:[DHCQ] ratio was 1.3 (range 1.0-1.7). [HCQ] was closely associated with [DHCQ] (r = 0.81, P < 0.0001). The weight-adjusted oral HCQ dose was strongly associated with both [HCQ] (P < 0.001) and [DHCQ] (P < 0.001). Time since last dose was associated with [HCQ] (P < 0.001). No statistically significant association was found between renal function or smoking and [HCQ] or [DHCQ]. Use of additional immunosuppressants increased both [HCQ] and [DHCQ] after adjusting for possible confounders (P = 0.04 and P = 0.03, respectively). The lower SLEDAI score was significantly related to higher [HCQ], after adjusting for age, sex, weight-adjusted HCQ dose, time since last dose, number of other immunosuppressants, and smoking status (P = 0.007). Various factors affected blood levels of [HCQ], [DHCQ], or the [HCQ]:[DHCQ] ratio of SLE patients receiving long-term oral HCQ treatment. Notably, higher [HCQ] was associated with a lower SLEDAI score in our typical outpatient clinic population with lupus. © 2016, American College of Rheumatology.

  8. Measuring Concentration in Data with an Exogenous Order

    OpenAIRE

    Abedieh, Jasmin; Groll, Andreas; Eugster, Manuel J. A.

    2013-01-01

    Concentration measures order the statistical units under observation according to their market share. However, there are situations where an order according to an exogenous variable is more appropriate or even required. The present article introduces a generalized definition of market concentration and defines a corresponding concentration measure. It is shown that this generalized concept of market concentration satisfies the common axioms of (classical) concentration measures. In an appl...

  9. A Negative Correlation Between Blood Glucose and Acetone Measured in Healthy and Type 1 Diabetes Mellitus Patient Breath.

    Science.gov (United States)

    Rydosz, Artur

    2015-07-01

    Exhaled acetone analysis has long been recognized as a supplementary tool for diagnosis and monitoring diabetes, especially type 1 diabetes. It is essential, therefore to determine the relationship between exhaled acetone concentration and glucose in blood. Usually, a direct linear correlation between this both compounds has been expected. However, in some cases we can observe a reverse correlation. When blood glucose was increasing, breath acetone declined. The breath analysis as a supplementary tool for diagnosing and monitoring diabetes makes sense only in case of utilization of portable analyzers. This need has created a market for gas sensors. However, commercially available acetone gas sensors are developed for measuring samples at several tens part per million. The exhaled acetone concentration was measured using commercial acetone gas sensor (TGS 822, 823 Figaro, Arlington Heights, IL, USA Inc) with micropreconcentrator in low temperature cofired ceramics. The reference analyzer-mass spectrometry (HPR-20 QIC, Hiden Analytical, Warrington, UK) was used. Twenty-two healthy volunteers with no history of any respiratory disease participated in the research, as did 31 patients diagnosed with type 1 diabetes. Respectively, 3 healthy volunteer and 5 type 1 diabetes mellitus subjects with reverse trend were selected. The linear fitting coefficient various from 0.1139 to 0.9573. Therefore, it is necessary to determine the correlation between blood glucose concentrations and under different conditions, for example, insulin levels, as well as correlate the results with clinical tests, for example, Hb1Ac. It is well known that the concentration of acetone is strongly influenced by diet, insulin treatment, and so on. Therefore, much more complex analysis with long-term measurements are required. Thus, presented results should be regarded as tentative, and validation studies with the analysis of clinical test and in a large number of patients, including control groups

  10. Simple technique for measuring relative renal blood flow

    International Nuclear Information System (INIS)

    Shames, D.M.; Korobkin, M.

    1976-01-01

    To determine whether externally monitored early renal uptake of 131 I-hippurate is proportional to renal blood flow, the renal uptake of 131 -hippurate at 1 to 2 min after injection was compared with the renal accumulation of radioactive carbonized microspheres in dogs. A renal artery catheter equipped with a balloon was used to decrease renal blood flow unilaterally. One minute after the intravenous injection of 100 μCi of 131 I-hippurate, about 1 μCi of either 85 Sr- or 95 Nb-labeled carbon microspheres was injected into the left ventricle. Radioactivity was measured over both kidneys. The total radioactivity within each kidney region of interest was corrected for background and integrated over the 1 to 2 min interval after injection. Thirteen measurements of relative renal blood flow were made for seven dogs. The dogs were then killed and both kidneys were excised and counted for the radioactivity of the microspheres. The 1 to 2-min relative renal uptake of 131 I-hippurate correlated well with relative microsphere uptake, suggesting that relative renal blood flow can be simply determined from the external measurements of renal uptake of 131 I-hippurate

  11. Recalculation of measured fuel nuclide concentrations

    International Nuclear Information System (INIS)

    Moeller, W.

    1984-01-01

    The concentrations and concentration ratios of heavy fuel nuclides determined in the Central Institute for Nuclear Research Rossendorf on the basis of destructive burnup measurements are compared with the results of microburnup calculations. The possibility is discussed to improve the results by taking into account the spectral characteristics at the positions of the measuring samples. (author)

  12. Liver kinetics of glucose analogs measured in pigs by PET: importance of dual-input blood sampling

    DEFF Research Database (Denmark)

    Munk, O L; Bass, L; Roelsgaard, K

    2001-01-01

    -input functions were very similar. CONCLUSION: Compartmental analysis of MG and FDG kinetics using dynamic PET data requires measurements of dual-input activity concentrations. Using the dual-input function, physiologically reasonable parameter estimates of K1, k2, and Vp were obtained, whereas the use......Metabolic processes studied by PET are quantified traditionally using compartmental models, which relate the time course of the tracer concentration in tissue to that in arterial blood. For liver studies, the use of arterial input may, however, cause systematic errors to the estimated kinetic...... parameters, because of ignorance of the dual blood supply from the hepatic artery and the portal vein to the liver. METHODS: Six pigs underwent PET after [15O]carbon monoxide inhalation, 3-O-[11C]methylglucose (MG) injection, and [18F]FDG injection. For the glucose scans, PET data were acquired for 90 min...

  13. The influence of sodium propionate on blood glucose, insulin and cortisol concentrations in calves of different ages

    Directory of Open Access Journals (Sweden)

    Biljana Radojičić

    2016-01-01

    Full Text Available The process of gluconeogenesis in ruminants is under the direct influence of insulin and glucocorticoid hormones. The goal of this study was to determine the effects of added Na-propionate on the neuroendocrine regulation of blood glucose in calves at three specific physiological periods: on exclusive milk nutrition; on mixed milk and forage nutrition; and with established ruminant digestion. The influence of Na-propionate on blood glucose, insulin and cortisol concentrations was examined in the same 20 female Holstein calves at different stages of forestomach development (15 days, 2 months, and 4 months of age of calves. Group 1 of calves (n = 10 received Na-propionate intravenously; group 2 (n = 10 received Na-propionate mixed in milk. Blood sampling was performed 1 and 3 h after Na-propionate administration. After i.v. administration of Na-propionate, a significant increase (P < 0.05 in blood glucose concentration was observed 1 h after administration only in calves aged 2 and 4 months; blood insulin concentration was significantly higher (P < 0.01 1 and 3 h after i.v. administration in 2-month-old calves; and cortisol concentration increased (P < 0.01 1 h after administration in each selected calf in all testing periods. Orally administered Na-propionate led to a significant increase (P < 0.01 of insulin concentration 1 and 3 h after administration in 15-day-old calves, and 3 h after administration in 2-month-old calves. Based on these results it could be assumed that i.v. and p.o. administration of Na-propionate affects the neuroendocrine regulation of glycaemia in calves of different age.

  14. X-ray PIV measurements of blood flows without tracer particles

    International Nuclear Information System (INIS)

    Kim, Guk Bae; Lee, Sang Joon

    2006-01-01

    We analyzed the non-Newtonian flow characteristics of blood moving in a circular tube flow using an X-ray PIV method and compared the experimental results with hemodynamic models. The X-ray PIV method was improved for measuring quantitative velocity fields of blood flows using a coherent synchrotron X-ray. Without using any contrast media, this method can visualize flow pattern of blood by enhancing the phase-contrast and interference characteristics of blood cells. The enhanced X-ray images were achieved by optimizing the sample-to-scintillator distance, the sample thickness, and hematocrit in detail. The quantitative velocity fields of blood flows inside opaque conduits were obtained by applying a two-frame PIV algorithm to the X-ray images of the blood flows. The measured velocity data show typical features of blood flow such as the yield stress and shear-thinning effects. (orig.)

  15. Self-monitoring of blood glucose measurements and glycaemic ...

    African Journals Online (AJOL)

    Background. Intensive diabetes management requires intensive insulin treatment and self-monitoring of blood glucose (SMBG) measurements to obtain immediate information on the status of the blood glucose level and to obtain data for pattern analysis on which meal planning, insulin and lifestyle adjustments can be ...

  16. Association of adiposity measures with blood lipids and blood pressure in children aged 8-11 years.

    Science.gov (United States)

    Vizcaíno, Vicente Martínez; Aguilar, Fernando Salcedo; Martínez, Montserrat Solera; López, Mairena Sánchez; Gutiérrez, Ricardo Franquelo; Rodríguez-Artalejo, Fernando

    2007-09-01

    To examine the association of body mass index (BMI), triceps skinfold thickness (TST) and percentage body fat (%BF) from bioelectrical impedance analysis (BIA) with blood lipids, systolic blood pressure (SBP) and diastolic blood pressure (DBP) in children. Cross-sectional study was conducted on 1280 schoolchildren aged 8-11 years from the Cuenca province (Spain). Data collection was conducted under standardized conditions, taking several measurements of each variable to enhance accuracy. Analyses were performed using age-adjusted correlation coefficients, and multiple linear regression adjusted for age, BMI, TST and %BF. Correlations between %BF and apolipoprotein (apo) B, total cholesterol, low-density lipoprotein cholesterol (LDL-c), total cholesterol/HDL-c ratio and DBP were higher than those for BMI and TST. In contrast, the correlations between BMI, and apo A-I and SBP were higher than those for %BF and TST. The results were similar across the sexes. The correlations between each of the three measures of body fatness, and blood lipids and blood pressure were highest in children with greatest BMI and %BF. When analyses were adjusted for the three body fatness measures, %BF showed stronger associations than did BMI or TST with blood lipids and blood pressure, with the exception of apo A-I and SBP, which were more closely associated with BMI. %BF from BIA is more strongly associated than either BMI or TST with most of the blood lipid fractions in schoolchildren aged 8-11 years.

  17. Cortisol and prolactin concentrations during repeated blood sample collection from freely moving, mouse-sized mammals (Phodopus spp.).

    Science.gov (United States)

    Reburn, C J; Wynne-Edwards, K E

    2000-04-01

    Validation of a method for obtaining blood samples that does not change cortisol or prolactin concentrations yet allows serial blood samples to be collected from animals under anesthesia, without prior handling, from freely interacting social groups of small mammals. Results from five experiments are reported. Male dwarf hamsters (Phodopus spp.) were housed in modified home cages under continuous flow of compressed air that could be switched to isoflurane in O2 vehicle without approaching the cages. Dwarf hamsters respond to manual restraint with behavioral distress and increase in the concentration of the dominant glucocorticoid, cortisol, and decrease in prolactin concentration. Both effects are evident within one minute. In contrast, when this new method was used, neither cortisol nor prolactin changed in response to repeated sample collection (up to 8 successive samples at 2 hour intervals), prolonged isoflurane exposure, or substantial blood volume reduction (30%). Prolactin concentration was suppressed and cortisol concentration was increased in response to stimuli from other hamsters tested without anesthesia. Suppression of prolactin concentration was graded in response to the degree of stress and equaled the pharmacologic reduction caused by bromocryptine mesylate (50 microg of CB154 x 3 days). The technique is superior to alternatives for studies of behavioral endocrinology of freely interacting small mammals.

  18. Placental blood flow measurements with radioisotopes in the pregnant guinea pig

    International Nuclear Information System (INIS)

    Schmitt, R.; Giese, W.; Kurz, C.S.; Kuenzel, W.

    1976-01-01

    In 15 pregnant guinea pigs near term the blood flow (BF) of the myometrium and the placenta as well as the cardiac output were measured with 99 Tcsup(m)-labelled microspheres. In front of one placenta the clearance of 133 Xe was estimated in the same animal. For the 133 Xe measurement a theoretical concept is presented. The mean placental BF is 105ml/(minx100g)(SD:84) for 99 Tcsup(m) and 244(SD:80)ml/(minx100g) for 133 Xe. The difference in both flow values is assumed to be related to foetal placental BF. The placental blood flow is also related to the location of the placenta in the uterine horn. The ratio of myometrial blood flow to placental blood flow decreased with an increase in the mean arterial blood pressure. The measurements are a preliminary report of an attempt to compare two different methods in measuring placental blood flow. (author)

  19. Noninvasive measurement of blood flow and extraction fraction

    Energy Technology Data Exchange (ETDEWEB)

    Peters, A.M.; Gunasekera, R.D.; Henderson, B.L.; Brown, J.; Lavender, J.P.; De Souza, M.; Ash, J.M.; Gilday, D.L.

    1987-10-01

    We describe the theory of a technique for the noninvasive measurement of organ blood flow which is based on the principle of fractionation of cardiac output and is applicable with any recirculating gamma emitting tracer. The technique effectively determines the count rate that would be recorded over the organ if the tracer behaved like radiolabelled microspheres and was completely trapped in the organ's vascular bed on first pass. After correction for organ depth, the estimated first pass activity plateau, expressed as a fraction of the injected dose is equal to the organ's fraction of the cardiac output (CO). By extending the theory, organ extraction fraction of extractable tracers or mean transit time of nonextractable tracers can be measured. The technique was applied to the measurement of renal blood flow in the native and transplanted kidney, splenic blood flow, the extraction fraction of DTPA by the kidney and of sulphur colloid by the spleen.

  20. Noninvasive measurement of blood flow and extraction fraction

    International Nuclear Information System (INIS)

    Peters, A.M.; Gunasekera, R.D.; Henderson, B.L.; Brown, J.; Lavender, J.P.; De Souza, M.; Ash, J.M.; Gilday, D.L.

    1987-01-01

    We describe the theory of a technique for the noninvasive measurement of organ blood flow which is based on the principle of fractionation of cardiac output and is applicable with any recirculating gamma emitting tracer. The technique effectively determines the count rate that would be recorded over the organ if the tracer behaved like radiolabelled microspheres and was completely trapped in the organ's vascular bed on first pass. After correction for organ depth, the estimated first pass activity plateau, expressed as a fraction of the injected dose is equal to the organ's fraction of the cardiac output (CO). By extending the theory, organ extraction fraction of extractable tracers or mean transit time of nonextractable tracers can be measured. The technique was applied to the measurement of renal blood flow in the native and transplanted kidney, splenic blood flow, the extraction fraction of DTPA by the kidney and of sulphur colloid by the spleen. (author)

  1. Study on the Changes in Enzyme and Insulin-like Growth Factor-1 Concentrations in Blood Serum and Growth Characteristics of Velvet Antler during the Antler Growth Period in Sika Deer (

    Directory of Open Access Journals (Sweden)

    Jaehyun Park

    2015-09-01

    Full Text Available This study was conducted to investigate changes in blood enzyme parameters and to evaluate the relationship between insulin-like growth factor-1 (IGF-1, antler growth and body weight during the antler growth of sika deer (Cervus nippon. Serum enzyme activity and IGF-1 concentrations were measured in blood samples collected from the jugular and femoral veins at regular intervals during the antler growth period. Blood samples were taken in the morning from fasted stags (n = 12 which were healthy and showed no clinical signs of disease. Alfalfa was available ad libitum and concentrates were given at 1% of body weight to all stags. The experimental diet was provided at 9 am with water available at all times. There were no significant differences in alkaline phosphatase, aspartate aminotransferase, and alanine aminotransferase during antler growth, but alkaline phosphatase concentrations increased with antler growth progression, and the highest alkaline phosphatase concentration was obtained 55 days after antler casting. Serum IGF-1 concentrations measured from blood samples taken from the jugular vein during antler growth, determined that levels of IGF-1 was associated with body weight and antler growth patterns. Serum IGF-1 concentrations were higher at the antler cutting date than other sampling dates. Antler length increased significantly during antler growth (p<0.001, and there was a similar trend to between right and left beams. Body weight increased with antler growth but was not significant. Consequently it appeared that serum alkaline phosphatase concentration was related to antler growth and both antler growth and body weight were associated positively with IGF-1 concentrations during antler growth.

  2. Relationship between blood harmane and harmine concentrations in familial essential tremor, sporadic essential tremor and controls.

    Science.gov (United States)

    Louis, Elan D; Jiang, Wendy; Gerbin, Marina; Mullaney, Mary M; Zheng, Wei

    2010-12-01

    Harmane, a potent tremor-producing β-carboline alkaloid, may play a role in the etiology of essential tremor (ET). Blood harmane concentrations are elevated in ET cases compared with controls yet the basis for this elevation remains unknown. Decreased metabolic conversion (harmane to harmine) is one possible explanation. Using a sample of >500 individuals, we hypothesized that defective metabolic conversion of harmane to harmine might underlie the observed elevated harmane concentration in ET, and therefore expected to find a higher harmane to harmine ratio in familial ET than in sporadic ET or controls. Blood harmane and harmine concentrations were quantified by high performance liquid chromatography. There were 78 familial ET cases, 187 sporadic ET cases, and 276 controls. Blood harmane and harmine concentrations were correlated with one another (Spearman's r=0.24, p<0.001). The mean (±SD) harmane/harmine ratio=23.4±90.9 (range=0.1-987.5). The harmane/harmine ratio was highest in familial ET (46.7±140.4), intermediate in sporadic ET (28.3±108.1), and lowest in controls (13.5±50.3) (p=0.03). In familial ET cases, there was no association between this ratio and tremor severity (Spearman's r=0.08, p=0.48) or tremor duration (Spearman's r=0.14, p=0.24). The basis for the elevated blood harmane concentration, particularly in familial ET, is not known, although the current findings (highest harmane/harmine ratio in familial ET cases) lends support to the possibility that it could be the result of a genetically-driven reduction in harmane metabolism. Copyright © 2010 Elsevier Inc. All rights reserved.

  3. Platelet aggregation and quality control of platelet concentrates produced in the Amazon Blood Bank

    Directory of Open Access Journals (Sweden)

    Maria José Dantas Coêlho

    2011-01-01

    Full Text Available BACKGROUND: The study of platelet aggregation is essential to assess in vitro platelet function by different platelet activation pathways. OBJECTIVE: To assess aggregation and biochemical parameters of random platelet concentrates produced at the Fundação HEMOAM using the quality control tests defined by law. METHODS: Whole blood samples from 80 donors and the respective platelet concentrate units were tested. Platelet concentrates were tested (platelet count, aggregation and pH on days 1, 3 and 5 of storage. Additionally a leukocyte count was done only on day 1 and microbiological tests on day 5 of storage. Collagen and adenosine diphosphate were used as inducing agonists for platelet aggregation testing. RESULTS: Donor whole blood had normal aggregation (aggregation with adenosine diphosphate = 67% and with collagen = 78%. The median aggregation in platelet concentrates with adenosine diphosphate was low throughout storage (18% on day 1, 7% on day 3 and 6% on day 5 and the median aggregation with collagen was normal only on day 1 and low thereafter (54.4% on day 1, 20.5% on day 3 and 9% on day 5. CONCLUSION: Although the results were within the norms required by law, platelet concentrates had low aggregation rates. We suggest the inclusion of a functional assessment test for the quality control of platelet concentrates for a more effective response to platelet replacement therapy.

  4. Signal quality measures for unsupervised blood pressure measurement

    International Nuclear Information System (INIS)

    Abdul Sukor, J; Redmond, S J; Lovell, N H; Chan, G S H

    2012-01-01

    Accurate systolic and diastolic pressure estimation, using automated blood pressure measurement, is difficult to achieve when the transduced signals are contaminated with noise or interference, such as movement artifact. This study presents an algorithm for automated signal quality assessment in blood pressure measurement by determining the feasibility of accurately detecting systolic and diastolic pressures when corrupted with various levels of movement artifact. The performance of the proposed algorithm is compared to a manually annotated reference scoring (RS). Based on visual representations and audible playback of Korotkoff sounds, the creation of the RS involved two experts identifying sections of the recorded sounds and annotating sections of noise contamination. The experts determined the systolic and diastolic pressure in 100 recorded Korotkoff sound recordings, using a simultaneous electrocardiograph as a reference signal. The recorded Korotkoff sounds were acquired from 25 healthy subjects (16 men and 9 women) with a total of four measurements per subject. Two of these measurements contained purposely induced noise artifact caused by subject movement. Morphological changes in the cuff pressure signal and the width of the Korotkoff pulse were extracted features which were believed to be correlated with the noise presence in the recorded Korotkoff sounds. Verification of reliable Korotkoff pulses was also performed using extracted features from the oscillometric waveform as recorded from the inflatable cuff. The time between an identified noise section and a verified Korotkoff pulse was the key feature used to determine the validity of possible systolic and diastolic pressures in noise contaminated Korotkoff sounds. The performance of the algorithm was assessed based on the ability to: verify if a signal was contaminated with any noise; the accuracy, sensitivity and specificity of this noise classification, and the systolic and diastolic pressure

  5. Cine-CT measurement of cortical renal blood flow

    International Nuclear Information System (INIS)

    Jaschke, W.R.; Gould, R.G.; Cogan, M.G.; Sievers, R.; Lipton, M.J.

    1987-01-01

    A modified indicator-dilution technique using radiographic contrast material and a cine-CT scanner was used to measure blood flow in the renal cortex of dogs. To validate this technique, CT measurements were correlated with simultaneous measurements of flow determined by radioactive microspheres. Measurements were taken during euvolemic conditions and after hemorrhage. Thirty-nine measurements were compared, covering a flow range from 1 to 7 ml min-1 g-1, and a good correlation was found between the cine-CT and microsphere results (r = 0.93; p less than 0.001). Additionally, cine-CT measurements were made of the mean transit time (MTT) of contrast material through the renal cortex, and the reciprocal of these MTT values was also well correlated to microsphere determined flow (r = 0.94; p less than 0.001). Thus, cine-CT appears to be a promising new technique for measuring renal blood flow

  6. A rapid liquid chromatography tandem mass spectrometry-based method for measuring propranolol on dried blood spots.

    Science.gov (United States)

    Della Bona, Maria Luisa; Malvagia, Sabrina; Villanelli, Fabio; Giocaliere, Elisa; Ombrone, Daniela; Funghini, Silvia; Filippi, Luca; Cavallaro, Giacomo; Bagnoli, Paola; Guerrini, Renzo; la Marca, Giancarlo

    2013-05-05

    Propranolol, a non-selective beta blocker drug, is used in young infants and newborns for treating several heart diseases; its pharmacokinetics has been extensively evaluated in adult patients using extrapolation to treat pediatric population. The purpose of the present study was to develop and validate a method to measure propranolol levels in dried blood spots. The analysis was performed by using liquid chromatography/tandem mass spectrometry operating in multiple reaction monitoring mode. The calibration curve in matrix was linear in the concentration range of 2.5-200 μg/L with correlation coefficient r=0.9996. Intra-day and inter-day precisions and biases were less than 8.0% (n=10) and 11.5% (n=10) respectively. The recoveries ranged from 94 to 100% and the matrix effect did not result in a severe signal suppression. Propranolol on dried blood spot showed a good stability at three different temperatures for one month. This paper describes a micromethod for measuring propranolol levels on dried blood spot, which determines a great advantage in neonates or young infants during pharmacokinetic studies because of less invasive sampling and small blood volume required. Copyright © 2013 Elsevier B.V. All rights reserved.

  7. Hemoglobin in samples with leukocytosis can be measured on ABL 700 series blood gas analyzers

    NARCIS (Netherlands)

    Scharnhorst, V.; Laar, van der P.D.; Vader, H.

    2003-01-01

    To compare lactate, bilirubin and Hemoglobin F concentrations obtained on ABL 700 series blood gas analyzers with those from laboratory methods. Pooled neonatal plasma, cord blood and adult plasma samples were used for comparison of bilirubin, hemoglobin F and lactate concentrations respectively.

  8. Blood carboxyhaemoglobin and cyanide levels in fire survivors

    Energy Technology Data Exchange (ETDEWEB)

    Clark, C.J.; Campbell, D.; Reid, W.H.

    1981-06-20

    Blood carboxyhaemoglobin and cyanide concentrations were measured in 53 fire survivors, 36 of whom had clinical evidence of smoke inhalation. Carboxyhaemoglobin and cyanide levels were raised only in patients with smoke inhalation. Blood carboxyhaemoglobin measurement can be used to confirm the diagnosis of severe smoke inhalation in cases in which the clinical data are inconclusive, provided that the time of sampling after exposure is taken into account. A nomogram has been constructed for this purpose. There is no quick method of measuring blood cyanide levels, but the close relation between cyanide and carboxyhaemoglobin levels suggests that carboxyhaemoglobin concentrations, which can be rapidly and easily measured, could be used to identify those who might benefit from treatment with cyanide antidotes.

  9. The relation between the blood benzodiazepine concentration and performance in suspected impaired drivers

    NARCIS (Netherlands)

    Smink, B.E.; Lusthof, K.J.; de Gier, J.J.; Uges, D.R.; Egberts, A.C.

    2008-01-01

    Several experimental studies have shown a negative influence of benzodiazepines on driving skills. The objective of this study is to study the relationship between the blood concentration of benzodiazepines and the influence on performance in field sobriety tests. A retrospective case file

  10. Measurement of tritium concentration in urine

    International Nuclear Information System (INIS)

    Sekiyama, Shigenobu; Deshimaru, Takehide

    1979-01-01

    Concerning the safety management of the advanced thermal reactor ''Fugen'', the internal exposure management for tritium is important, because heavy water is used as the moderator in the reactor, and tritium is produced in the heavy water. Tritium is the radioactive nuclide with the maximum β-ray energy of 18 keV, and the radiation exposure is limited to the internal exposure in human bodies, as tritium is taken in through the skin and by breathing. The tritium concentration in urine of the operators of the Fugen plant was measured. As for tritium measurement, the analysis of raw urine, the analysis after passing through mixed ion exchange resin and the analysis after distillation are applied. The scintillator, the liquid scintillation counter, the ion exchange resin and the distillator are introduced. The preliminary survey was conducted on the urine sample, the scintillator the calibration, etc. The measuring condition, the measurement of efficiency, and the limitation of detection with various background are explained, with the many experimental data and the calculating formula. Concerning the measured tritium concentration in urine, the tritium concentrations in distilled urine, raw urine and the urine refined with ion exchange resin were compared, and the correlation formulae are presented. The actual tritium concentration value in urine was less than 50 pci/ml. The measuring methods of raw urine and the urine refined with ion exchange resin are adequate as they are quick and accurate. (Nakai, Y.)

  11. BLOOD METABOLIC HORMONES AND LEPTIN IN GROWING LAMBS

    Directory of Open Access Journals (Sweden)

    Zvonko Antunović

    2010-12-01

    Full Text Available The aim of this paper is to determine the concentration of blood metabolic hormones and leptin levels in growing lambs. The research was carried out on Tsigai lambs in two periods (suckling and fattening during the winter feeding season. Lambs were suckling and ate a food mixture and alfalfa hay ad libitum, while during the fattening period they were fed only with the above mentioned mixture and alfalfa hay ad libitum. Their blood was analyzed on 35th and 75th day of age. Concentrations of minsulin, leptin and thyroid hormones were determined in the blood serum of lambs during both periods. In the blood of fattening lambs significantly higher (P0.05 insulin concentrations (1.05 and 0.54 μU/mL, were determined, compared to suckling lambs. A significant strong positive correlation between serum leptin and insulin (r = 0.85, P0.05. The concentration of thyroid hormones did not significantly differ depending on the period of measurement. These changes indicate that the measurement concentrations of metabolic hormones and leptin in blood are very important in order to understand the changes of metabolism and nutrient supply in growing lambs.

  12. Concentration of total proteins in blood plasma of chickens hatched from irradiated eggs with low dose gamma radiation

    International Nuclear Information System (INIS)

    Vilic, M.; Kraljevic, P.; Miljanic, S.; Simpraga, M.

    2005-01-01

    It is known that low-dose ionising radiation may have stimulating effects on chickens. Low doses may also cause changes in the concentration of blood plasma total proteins, glucose and cholesterol in chickens. This study investigates the effects of low dose gamma-radiation on the concentration of total proteins in the blood plasma of chickens hatched from eggs irradiated with a dose of 0.15 Gy on incubation days 7 and 19. Results were compared with the control group (chickens hatched from non-irradiated eggs). After hatching, all other conditions were the same for both groups. Blood samples were drawn from the heart, and later from the wing vein on days 1, 3, 5, 7,10, 20, 30 and 42. The concentration of total proteins was determined spectrophotometrically using Boehringer Mannheim GmbH optimised kits. The concentration of total proteins in blood plasma in chickens hatched from eggs irradiated with 0.15 Gy on incubation day 7 showed a statistically significant decrease on the sampling day 3 (P less than 0.05) and 7 (P less than 0.01). The concentration of total proteins in blood plasma in chickens hatched from eggs irradiated with 0.15 Gy on incubation day 19 showed a statistically significant increase only on sampling day 1 (P less than 0.05). These results suggest that exposure of eggs to 0.15 Gy of gamma-radiation on the 7th and 19th day of incubation could produce different effects on the protein metabolism in chickens.(author)

  13. Concentration and correlations of perfluoroalkyl substances in whole blood among subjects from three different geographical areas in Korea

    Energy Technology Data Exchange (ETDEWEB)

    Cho, Chon Rae; Lam, Nguyen Hoang [College of Fisheries and Ocean Sciences, Chonnam National University, Yeosu 550-749 (Korea, Republic of); Cho, Byung Mann [Department of Preventive Medicine and Occupational Medicine, School of Medicine, Pusan National University, Yangsan 626-770 (Korea, Republic of); Kannan, Kurunthachalam [Wadsworth Center, New York State Department of Health and Department of Environmental Health Sciences, School of Public Health, State University of New York at Albany, Empire State Plaza PO Box 509, Albany, NY 12201-0509 (United States); Cho, Hyeon Seo, E-mail: hscho@jnu.ac.kr [College of Fisheries and Ocean Sciences, Chonnam National University, Yeosu 550-749 (Korea, Republic of)

    2015-04-15

    Toxicity and persistence of perfluorinated alkyl substances (PFASs) in human have raised considerable concern and several biomonitoring studies throughout the world reported the widespread occurrence of these compounds in human tissues. However, information regarding influence of geographic, lifestyle and demographic factor on PFAS levels in human blood tissues is limited. In this study, whole blood samples collected in 2006–2007 from 319 donors from suburban Seoul (Suwon and Yongin), Busan and Yeosu in Korea were analyzed for perfluorooctane sulfonate (PFOS), perfluorooctanoate (PFOA), perfluorononanoate (PFNA), perfluorohexane sulfonate (PFHxS) and perfluorooctane sulfonamide (PFOSA). Blood donors classified into seven age groups with ages ranging from 8 to 82 years, and different lifestyles and socio-economic status. PFOS (median = 4.15 ng/mL) was found at the highest concentration with a maximum concentration of 59.1 ng/mL. The concentrations of other PFASs were in the decreasing order of; PFOA (median = 1.30 ng/mL) > PFNA (median = 0.85 ng/mL) > PFHxS (median = 0.47 ng/mL) > PFOSA (median = 0.12 ng/mL). Geographical differences in the concentrations of five target PFASs were found. Significant positive relationships between PFAS concentrations and the age of the donors were found. Gender-related differences were found in the concentrations of PFOA, PFNA, PFHxS and PFOSA. No association was found between PFAS levels and several lifestyle factors and socio-economic status which included drinking habit, furniture/carpet in an indoor environment and monthly income. Occupation was an important determinant for PFNA and PFHxS concentrations in the whole blood. Except for PFOSA, significant associations were noted between PFASs concentrations and smoking habit. The results of this study provide information for further public health monitoring and safety management for PFASs in Korea. - Highlights: • Significant geographical differences in PFAS levels in whole

  14. Concentration and correlations of perfluoroalkyl substances in whole blood among subjects from three different geographical areas in Korea

    International Nuclear Information System (INIS)

    Cho, Chon Rae; Lam, Nguyen Hoang; Cho, Byung Mann; Kannan, Kurunthachalam; Cho, Hyeon Seo

    2015-01-01

    Toxicity and persistence of perfluorinated alkyl substances (PFASs) in human have raised considerable concern and several biomonitoring studies throughout the world reported the widespread occurrence of these compounds in human tissues. However, information regarding influence of geographic, lifestyle and demographic factor on PFAS levels in human blood tissues is limited. In this study, whole blood samples collected in 2006–2007 from 319 donors from suburban Seoul (Suwon and Yongin), Busan and Yeosu in Korea were analyzed for perfluorooctane sulfonate (PFOS), perfluorooctanoate (PFOA), perfluorononanoate (PFNA), perfluorohexane sulfonate (PFHxS) and perfluorooctane sulfonamide (PFOSA). Blood donors classified into seven age groups with ages ranging from 8 to 82 years, and different lifestyles and socio-economic status. PFOS (median = 4.15 ng/mL) was found at the highest concentration with a maximum concentration of 59.1 ng/mL. The concentrations of other PFASs were in the decreasing order of; PFOA (median = 1.30 ng/mL) > PFNA (median = 0.85 ng/mL) > PFHxS (median = 0.47 ng/mL) > PFOSA (median = 0.12 ng/mL). Geographical differences in the concentrations of five target PFASs were found. Significant positive relationships between PFAS concentrations and the age of the donors were found. Gender-related differences were found in the concentrations of PFOA, PFNA, PFHxS and PFOSA. No association was found between PFAS levels and several lifestyle factors and socio-economic status which included drinking habit, furniture/carpet in an indoor environment and monthly income. Occupation was an important determinant for PFNA and PFHxS concentrations in the whole blood. Except for PFOSA, significant associations were noted between PFASs concentrations and smoking habit. The results of this study provide information for further public health monitoring and safety management for PFASs in Korea. - Highlights: • Significant geographical differences in PFAS levels in whole

  15. A sup 125 I-radioimmunoassay for measuring androstenedione in serum and in blood-spot samples from neonates

    Energy Technology Data Exchange (ETDEWEB)

    Thomson, S.; Wallace, A.M.; Cook, B. (Stobhill Hospital, Glasgow (England))

    1989-08-01

    We developed a radioimmunoassay with a gamma-emitting radioligand to measure androstenedione in human serum and in dried blood-spot samples from newborns. Antisera were raised in rabbits against androstenedione linked to bovine serum albumin at positions 3, 6, or 11 on the steroid nucleus. Radioligands were prepared by linking ({sup 125}I)iodohistamine at positions 3, 6, or 11. Linkages were through either carboxymethyloxime or hemisuccinate bridges. All label and antibody combinations were examined, and the most sensitive and specific combination (antiserum raised against androstenedione-3-carboxymethyloxime-bovine serum albumin with an androstenedione-carboxymethyloxime-({sup 125}I)iodohistamine label) was selected for full evaluation. We report the performance of these selected reagents in an immunoassay for androstenedione in both serum and dried blood-spot samples from neonates. We measured concentrations of androstenedione in serum under normal and pathological conditions such as congenital adrenal hyperplasia and polycystic ovarian disease. Diurnal variation in normal men was observed. Androstenedione was measured in blood spots from neonates born at term or prematurely, with respiratory distress syndrome, or with congenital adrenal hyperplasia.

  16. Role of Metabolic Genes in Blood Aluminum Concentrations of Jamaican Children with and without Autism Spectrum Disorder

    Directory of Open Access Journals (Sweden)

    Mohammad H. Rahbar

    2016-11-01

    Full Text Available Aluminum is a neurotoxic metal with known health effects in animals and humans. Glutathione-S-transferase (GST genes and enzymes play a major role in detoxification of several heavy metals. Besides a direct relationship with oxidative stress; aluminum decreases GST enzyme activities. Using data from 116 Jamaican children; age 2–8 years; with Autism Spectrum Disorder (ASD and 116 sex- and age-matched typically developing (TD children; we investigated the association of polymorphisms in three GST genes (GSTP1; GSTM1; and GSTT1 with mean blood aluminum concentrations in children with and without ASD. Using log-transformed blood aluminum concentration as the dependent variable in a linear regression model; we assessed the additive and interactive effects of ASD status and polymorphisms in the three aforementioned GST genes in relation to blood aluminum concentrations. Although none of the additive effects were statistically significant (all p > 0.16; we observed a marginally significant interaction between GSTP1 Ile105Val (rs1695 and ASD status (p = 0.07; even after controlling for parental education level and consumption of avocado; root vegetables; and tuna (canned fish. Our findings indicate a significantly lower (p < 0.03 adjusted geometric mean blood aluminum concentration for TD children who had the Val/Val genotype (14.57 µg/L; compared with those with Ile/Ile or Ile/Val genotypes who had an adjusted geometric mean of 23.75 µg/L. However; this difference was not statistically significant among the ASD cases (p = 0.76. Our findings indicate that ASD status may be a potential effect modifier when assessing the association between GSTP1 rs1695 and blood aluminum concentrations among Jamaican children. These findings require replication in other populations.

  17. Noninvasive measurement of cardiopulmonary blood volume: evaluation of the centroid method

    International Nuclear Information System (INIS)

    Fouad, F.M.; MacIntyre, W.J.; Tarazi, R.C.

    1981-01-01

    Cardiopulmonary blood volume (CPV) and mean pulmonary transit time (MTT) determined by radionuclide measurements (Tc-99m HSA) were compared with values obtained from simultaneous dye-dilution (DD) studies (indocyanine green). The mean transit time was obtained from radionuclide curves by two methods: the peak-to-peak time and the interval between the two centroids determined from the right and left-ventricular time-concentration curves. Correlation of dye-dilution MTT and peak-to-peak time was significant (r = 0.79, p < 0.001), but its correlation with centroid-derived values was better (r = 0.86, p < 0.001). CPV values (using the centroid method for radionuclide technique) correlated significantly with values derived from dye-dilution curves (r = 0.74, p < 0.001). Discrepancies between the two were greater the more rapid the circulation (r = 0.61, p < 0.01), suggesting that minor inaccuracies of dye-dilution methods, due to positioning or delay of the system, can become magnified in hyperkinetic conditions. The radionuclide method is simple, repeatable, and noninvasive, and it provides simultaneous evaluation of pulmonary and systemic hemodynamics. Further, calculation of the ratio of cardiopulmonary to total blood volume can be used as an index of overall venous distensibility and relocation of intravascular blood volume

  18. Basal blood parameters of horses subjected to aerobic activity fed with lipidic concentrated

    Directory of Open Access Journals (Sweden)

    Kátia de Oliveira

    2012-02-01

    Full Text Available The feeding diets were evaluated containing low and high levels of soybean oil for horses athletes subjected to two protocols of aerobic training on the response of basal blood biochemical parameters. Four horses were used in latin square design with treatments in a 2 x 2 factorial arrangement. Treatments consisted levels of 5 and 15% oil concentrates and two aerobic training, 40' and 60' minutes. Plasmatic parameters were monitored, triglyceride (TG, total cholesterol (TC, glucose (GLU and lactate (LAC, during basal metabolism. The TG, TC, GLU and LAC from horses at rest were not affected (P> 0.05 neither of diet and physical activity, 0.21, 3.79, 4.18, 0.93 mmol L-1, respectively. It can be concluded that offer concentrate with high content of soybean oil to athletic horses in aerobic activities can be performed without altering the blood biochemical profile of basal metabolism.

  19. Immunocapture and microplate-based activity and quantity measurement of pyruvate dehydrogenase in human peripheral blood mononuclear cells.

    Science.gov (United States)

    Liu, Xiaowen; Pervez, Hira; Andersen, Lars W; Uber, Amy; Montissol, Sophia; Patel, Parth; Donnino, Michael W

    2015-01-01

    Pyruvate dehydrogenase (PDH) activity is altered in many human disorders. Current methods require tissue samples and yield inconsistent results. We describe a modified method for measuring PDH activity from isolated human peripheral blood mononuclear cells (PBMCs). RESULTS/METHODOLOGY: We found that PDH activity and quantity can be successfully measured in human PBMCs. Freeze-thaw cycles cannot efficiently disrupt the mitochondrial membrane. Processing time of up to 20 h does not affect PDH activity with proteinase inhibitor addition and a detergent concentration of 3.3% showed maximum yield. Sample protein concentration is correlated to PDH activity and quantity in human PBMCs from healthy subjects. Measuring PDH activity from PBMCs is a novel, easy and less invasive way to further understand the role of PDH in human disease.

  20. The colour of blood in skin: a comparison of Allen's test and photonics simulations.

    Science.gov (United States)

    Välisuo, Petri; Kaartinen, Ilkka; Kuokkanen, Hannu; Alander, Jarmo

    2010-11-01

    The colour of the skin reflects many physiological and pathological states of an individual. Usually, the skin colour is examined by the bare eye alone. Several scaling systems have been developed to quantify the sensory evaluation of skin colour. In this work, the reflectance of the skin is measured directly using an objective instrument. Haemoglobin inside the dermal circulation is one of the key factors of skin colour and it also has a major role in the appearance of many skin lesions and scars. To quantitatively measure and analyse such conditions, the relation between the skin colour and the haemoglobin concentration in the skin needs to be resolved. To examine the effect of blood concentration on the skin colour, five Allen's tests were performed on 20 persons. The skin colour change was measured using a spectrophotometer by changing the blood concentration by the Allen's test. Light interaction with the skin was simulated with a Monte Carlo model, tuning the blood concentration parameter until the simulated and the measured spectra matched, yielding the relationship between the skin colour and the blood concentration. The simulation produced spectra similar to those measured. The change in the blood concentration in the simulation model and in the skin produced changes similar to the spectra. The reflectance of the skin was found to be a nonlinear function of the blood concentration. The relationship found between skin colour and blood concentration makes it possible to quantify those skin conditions expressed by blood volume better than plain colour. © 2010 John Wiley & Sons A/S.

  1. Concentration and limit behaviors of stationary measures

    Science.gov (United States)

    Huang, Wen; Ji, Min; Liu, Zhenxin; Yi, Yingfei

    2018-04-01

    In this paper, we study limit behaviors of stationary measures of the Fokker-Planck equations associated with a system of ordinary differential equations perturbed by a class of multiplicative noise including additive white noise case. As the noises are vanishing, various results on the invariance and concentration of the limit measures are obtained. In particular, we show that if the noise perturbed systems admit a uniform Lyapunov function, then the stationary measures form a relatively sequentially compact set whose weak∗-limits are invariant measures of the unperturbed system concentrated on its global attractor. In the case that the global attractor contains a strong local attractor, we further show that there exists a family of admissible multiplicative noises with respect to which all limit measures are actually concentrated on the local attractor; and on the contrary, in the presence of a strong local repeller in the global attractor, there exists a family of admissible multiplicative noises with respect to which no limit measure can be concentrated on the local repeller. Moreover, we show that if there is a strongly repelling equilibrium in the global attractor, then limit measures with respect to typical families of multiplicative noises are always concentrated away from the equilibrium. As applications of these results, an example of stochastic Hopf bifurcation and an example with non-decomposable ω-limit sets are provided. Our study is closely related to the problem of noise stability of compact invariant sets and invariant measures of the unperturbed system.

  2. Measurement of concentration of heavy water

    International Nuclear Information System (INIS)

    Tsukamoto, Yuichi; Kondo, Mitsuo; Sakurai, Naoyuki

    1979-01-01

    The concentration of heavy water is measured as one of the technical management in the Fugen plant. The heavy water is used as the moderator in the reactor. The measuring method depends on the theory of light absorption. The light absorption range of heavy water spreads from near infrared to infrared zone. The near infrared absorption was adopted for the purpose, as the absorption is much larger in infrared zone, and the measurement has to be conducted, limiting the apparent absorption. This measuring method is available to determine the concentration of heavy water in the broad range exactly. The preparation of heavy water sample and the measurement of the absorption spectra of near infrared ray are explained, as the experimental procedure. The sample cell was made of quartz, and the spectroscope was the Hitachi 323 type. The resolving power is 100 nm and 27 nm for the wave length of 1000 nm and 2500 nm, respectively. Concerning the measured results, the absorption was recorded in the wave length range from 600 nm to 2600 nm, and for the heavy water concentration range from 0 to 99.77 wt. %. The peaks of absorption were located at the wave length of 1450, 1660, 1920, 1970, 2020 and 2600 nm. The three kinds of fundamental vibration mode of the molecules of both light and heavy water are shown, and the peaks belong to H 2 O, HDO and D 2 O, respectively. The relation between the absorption and the heavy water concentration, and that between the transmissivity and the wave length are shown, when the cell thickness was varied to 5 mm and 20 mm, and the heavy water concentration to 21%, 62% and 99.85%. (Nakai, Y.)

  3. Estimating the measurement uncertainty in forensic blood alcohol analysis.

    Science.gov (United States)

    Gullberg, Rod G

    2012-04-01

    For many reasons, forensic toxicologists are being asked to determine and report their measurement uncertainty in blood alcohol analysis. While understood conceptually, the elements and computations involved in determining measurement uncertainty are generally foreign to most forensic toxicologists. Several established and well-documented methods are available to determine and report the uncertainty in blood alcohol measurement. A straightforward bottom-up approach is presented that includes: (1) specifying the measurand, (2) identifying the major components of uncertainty, (3) quantifying the components, (4) statistically combining the components and (5) reporting the results. A hypothetical example is presented that employs reasonable estimates for forensic blood alcohol analysis assuming headspace gas chromatography. These computations are easily employed in spreadsheet programs as well. Determining and reporting measurement uncertainty is an important element in establishing fitness-for-purpose. Indeed, the demand for such computations and information from the forensic toxicologist will continue to increase.

  4. Noninvasive measurement of blood glucose level using mid-infrared quantum cascade lasers

    Science.gov (United States)

    Yoshioka, Kiriko; Kino, Saiko; Matsuura, Yuji

    2017-04-01

    For non-invasive measurement of blood glucose level, attenuated total reflection (ATR) absorption spectroscopy system using a QCL as a light source was developed. The results of measurement of glucose solutions showed that the system had a sensitivity that was enough for blood glucose measurement. In-vivo measurement using the proposed system based on QCL showed that there was a correlation between absorptions measured with human lips and blood glucose level.

  5. Arterio-venous concentration difference of [51Cr]EDTA after a single injection in man. Significance of renal function and local blood flow

    DEFF Research Database (Denmark)

    Rehling, M; Hyldstrup, L; Henriksen, Jens Henrik Sahl

    1989-01-01

    , whereas the difference was very sensitive to even small changes in forearm blood flow within the physiological range. For measurement of renal plasma clearance it is recommended to use one long period: from the time of injection until 300 min p.i. or longer. If the clearance period is too short, the use...... introduced in the measurement of renal plasma clearance and total plasma clearance by using venous blood samples instead of arterial. In 13 patients with GFR ranging from 29 to 150 ml min-1, Ca was higher than Cv immediately after the injection. After mean 38 min (range 12-82 min) the two curves crossed...... of venous samples will overestimate the true renal clearance. Plasma clearance determined by venous and arterial blood samples does not differ significantly as long as the concentration is followed from the time of injection and a long period is applied. When simplified plasma clearance techniques are used...

  6. Design of a thermal neutron field by 252Cf source for measurement of 10B concentrations in the blood samples for BNCT

    International Nuclear Information System (INIS)

    Naito, H.; Sakurai, Y.; Maruhashi, A.

    2006-01-01

    10 B concentrations in the blood samples for BNCT has been estimated due to amounts of prompt gamma rays from 10 B in the fields of thermal neutrons from a special guide tube attached to research reactor. A system using radioisotopes as the source of thermal neutron fields has advantages that are convenient and low cost because it doesn't need running of a reactor or an accelerator. The validity of 252 Cf as a neutron source for 10 B concentrations detection system was investigated. This system is composed of D 2 O moderator, Pb reflector/filter, C reflector, and LiF filter. A thermal neutron field with low background gamma-rays is obtained. A large source of 252 Cf is required to obtain a sufficient flux. (author)

  7. Comparison of a New Cobinamide-Based Method to a Standard Laboratory Method for Measuring Cyanide in Human Blood

    Science.gov (United States)

    Swezey, Robert; Shinn, Walter; Green, Carol; Drover, David R.; Hammer, Gregory B.; Schulman, Scott R.; Zajicek, Anne; Jett, David A.; Boss, Gerry R.

    2013-01-01

    Most hospital laboratories do not measure blood cyanide concentrations, and samples must be sent to reference laboratories. A simple method is needed for measuring cyanide in hospitals. The authors previously developed a method to quantify cyanide based on the high binding affinity of the vitamin B12 analog, cobinamide, for cyanide and a major spectral change observed for cyanide-bound cobinamide. This method is now validated in human blood, and the findings include a mean inter-assay accuracy of 99.1%, precision of 8.75% and a lower limit of quantification of 3.27 µM cyanide. The method was applied to blood samples from children treated with sodium nitroprusside and it yielded measurable results in 88 of 172 samples (51%), whereas the reference laboratory yielded results in only 19 samples (11%). In all 19 samples, the cobinamide-based method also yielded measurable results. The two methods showed reasonable agreement when analyzed by linear regression, but not when analyzed by a standard error of the estimate or paired t-test. Differences in results between the two methods may be because samples were assayed at different times on different sample types. The cobinamide-based method is applicable to human blood, and can be used in hospital laboratories and emergency rooms. PMID:23653045

  8. Measurement of regional pulmonary blood volume in patients with increased pulmonary blood flow or pulmonary arterial hypertension

    International Nuclear Information System (INIS)

    Wollmer, P.; Rozcovek, A.; Rhodes, C.G.; Allan, R.M.; Maseri, A.

    1984-01-01

    The effects of chronic increase in pulmonary blood flow and chronic pulmonary hypertension on regional pulmonary blood volume was measured in two groups of patients. One group of patients had intracardiac, left-to-right shunts without appreciable pulmonary hypertension, and the other consisted of patients with Eisenmenger's syndrome or primary pulmonary hypertension, i.e. patients with normal or reduced blood flow and severe pulmonary hypertension. A technique based on positron tomography was used to measure lung density (by transmission scanning) and regional pulmonary blood volume (after inhalation of /sup 11/CO). The distribution of pulmonary blood volume was more uniform in patients with chronic increase in pulmonary blood flow than in normal subjects. There were also indications of an absolute increase in intrapulmonary blood volume by about 15%. In patients with chronic pulmonary arterial hypertension, the distribution of pulmonary blood volume was also abnormally uniform. There was, however, no indication that overall intrapulmonary blood volume was substantially different from normal subjects. The abnormally uniform distribution of pulmonary blood volume can be explained by recruitment and/or dilatation of vascular beds. Intrapulmonary blood volume appears to be increased in patients with intracardiac, left-to-right shunts. With the development of pulmonary hypertension, intrapulmonary blood volume falls, which may be explained by reactive changes in the vasculature and/or obliteration of capillaries

  9. Blood vitamin D(3) metabolite concentrations of adult female bearded dragons (Pogona vitticeps) remain stable after ceasing UVb exposure.

    Science.gov (United States)

    Oonincx, D G A B; van de Wal, M D; Bosch, G; Stumpel, J B G; Heijboer, A C; van Leeuwen, J P T M; Hendriks, W H; Kik, M

    2013-07-01

    Vitamin D deficiency can lead to several health problems collectively called metabolic bone disease (MBD). One commonly kept reptile species prone to develop MBD if managed incorrectly is the bearded dragon (Pogona vitticeps). This study aimed to determine the extent to which adult female bearded dragons fed a diet low in vitamin D can use stored vitamin D and its metabolites to maintain plasma 25(OH)D(3) and 1,25(OH)(2)D(3) concentrations after discontinuing UVb exposure. Blood samples of healthy adult female bearded dragons, exposed to UVb radiation for over 6 months were collected (day 0) after which UVb exposure was discontinued for 83 days and blood was collected. Blood plasma was analysed for concentrations of total Ca, total P, ionized Ca, uric acid, 25(OH)D(3) and 1,25(OH)(2)D(3). There was no significant change in plasma 25(OH)D(3) and 1,25(OH)(2)D(3) concentrations during the study. While total Ca and P in whole blood was found to significantly decrease over time (P dragons, previously exposed to UVb, are able to maintain blood vitamin D metabolite concentrations when UVb exposure is discontinued for a period of up to 83 days. Copyright © 2013 Elsevier Inc. All rights reserved.

  10. The increased concentration of 2,3-diphosphoglycerate in red blood cells of spontaneously hypertensive rats.

    Science.gov (United States)

    Przybylski, J; Skotnicka-Fedorowicz, B; Lisiecka, A; Siński, M; Abramczyk, P

    1997-12-01

    It has been recognised that high haemoglobin oxygen capacity is essential for the development of high blood pressure in spontaneously hypertensive rats. In the present study we have found increased concentration of 2,3 diphosphoglycerate (2,3-DPG) in red blood cells of spontaneously hypertensive rats (SHR) of Okamoto-Aoki strain. As 2,3-DPG is the major factor decreasing haemoglobin affinity to oxygen, our finding suggests that at given value of pO2 oxygen delivery to the tissue of SHR would be increased. Therefore increased concentration of 2,3-DPG in red blood cells of SHR would be of the pathophysiological meaning by promoting autoregulatory increase in total vascular resistance in this strain of rats. The mechanism responsible for enhanced synthesis of 2,3-DPG in SHR remains unclear. Intracellular alkalosis due to either hypocapnia and/or an enhanced activity of Na+/H+ antiporter occurring in SHR are the most plausible explanations for the above finding.

  11. Interlaboratory comparability of serum cotinine measurements at smoker and nonsmoker concentration levels: A round-robin study

    Science.gov (United States)

    Jacob, Peyton; Holiday, David B.; Benowitz, Neal L.; Sosnoff, Connie S.; Doig, Mira V.; Feyerabend, Colin; Aldous, Kenneth M.; Sharifi, Mehran; Kellogg, Mark D.; Langman, Loralie J.

    2009-01-01

    Introduction: Cotinine, the primary proximate metabolite of nicotine, is commonly measured as an index of exposure to tobacco in both active users of tobacco and nonsmokers with possible exposure to secondhand smoke (SHS). A number of laboratories have implemented analyses for measuring serum cotinine in recent years, but there have been few interlaboratory comparisons of the results. Among nonsmokers exposed to SHS, the concentration of cotinine in blood can be quite low, and extensive variability in these measurements has been reported in the past. Methods: In this study, a group of seven laboratories, all experienced in serum cotinine analysis, measured eight coded serum pools with concentrations ranging from background levels of about 0.05 ng/ml to relatively high concentrations in the active smokers range. All laboratories used either gas–liquid chromatography with nitrogen–phosphorus detection or liquid chromatography with mass spectrometric detection. Results: All seven laboratories reliably measured the cotinine concentrations in samples that were within the range of their methods. In each case, the results for the pools were correctly ranked in order, and no significant interlaboratory bias was observed at the 5% level of significance for results from any of the pools. Discussion: We conclude that present methods of chromatographic analysis of serum cotinine, as used by these experienced laboratories, are capable of providing accurate and precise results in both the smoker and the nonsmoker concentration range. PMID:19933777

  12. Blood Biochemistry and Plasma Corticosterone Concentration in Broiler Chickens Under Heat Stress

    Directory of Open Access Journals (Sweden)

    Elvis Alexander Díaz López

    2014-07-01

    Full Text Available High ambient temperatures cause susceptibility to heat stress in broiler chickens, generating metabolic changes. This paper seeks to determine the changes in blood biochemistry and plasma corticosterone concentration, as well as in glucose, total protein, albumin, globulin, sodium, chlorine, potassium, magnesium, phosphorus, and calcium in broiler chickens under chronic heat stress and at ambient temperature conditions at the Colombian Amazonian piedmont. 21-days-old male chickens of two lines were studied, distributed in an unrestricted random design, in a two-factor scheme, with four treatments. Five repetitions per treatment were performed, and 25 animals per experimental unit examined. Broilers were fed a basic diet of corn and soybean meal with 3,100 kcal ME and 19.5% protein until they reached 42 days of age. The line factor had no effect on the evaluated variables (p ≥ 0.05. However, there was statistically significant difference (p ≤ 0.05 in all variables when concentrations of metabolites in broilers under chronic heat stress were compared to those of chickens exposed to ambient temperatures at the Colombian Amazon piedmont. In conclusion, blood biochemistry suffered significant changes under both experimental temperatures, with more physiological detriment in broilers under chronic heat stress. Concentration of corticosterone became the most sensitive and consistent indicator of the physiological condition of chronic heat stress.

  13. [Mobile Health: IEEE Standard for Wearable Cuffless Blood Pressure Measuring Devices].

    Science.gov (United States)

    Zhou, Xia; Wu, Wenli; Bao, Shudi

    2015-07-01

    IEEE Std 1708-2014 breaks through the traditional standards of cuff based blood pressure measuring devices and establishes a normative definition of wearable cuffless blood pressure measuring devices and the objective performance evaluation of this kind of devices. This study firstly introduces the background of the new standard. Then, the standard details will be described, and the impact of cuffless blood pressure measuring devices with the new standard on manufacturers and end users will be addressed.

  14. Preanalytical Biases in the Measurement of Human Blood Sphingolipids

    Directory of Open Access Journals (Sweden)

    Robert Brunkhorst

    2018-05-01

    Full Text Available Dysregulation of blood sphingolipids is an emerging topic in clinical science. The objective of this study was to determine preanalytical biases that typically occur in clinical and translational studies and that influence measured blood sphingolipid levels. Therefore, we collected blood samples from four healthy male volunteers to investigate the effect of storage conditions (time, temperature, long-term storage, freeze–thaw cycles, blood drawing (venous or arterial sampling, prolonged venous compression, and sample preparation (centrifugation, freezing on sphingolipid levels measured by LC-MS/MS. Our data show that sphingosine 1-phosphate (S1P and sphinganine 1-phosphate (SA1P were upregulated in whole blood samples in a time- and temperature-dependent manner. Increased centrifugation at higher speeds led to lower amounts of S1P and SA1P. All other preanalytical biases did not significantly alter the amounts of S1P and SA1P. Further, in almost all settings, we did not detect differences in (dihydroceramide levels. In summary, besides time-, temperature-, and centrifugation-dependent changes in S1P and SA1P levels, sphingolipids in blood remained stable under practically relevant preanalytical conditions.

  15. Effect of age on heart rate, blood lactate concentration, packed cell volume and hemoglobin to exercise in Jeju crossbreed horses

    Directory of Open Access Journals (Sweden)

    Ok-Deuk Kang

    2017-01-01

    Full Text Available Abstract Background This study aimed to analyze the on heart rate, blood lactate concentration, packed cell volume (PCV and hemoglobin (Hb response after conducting exercise in endurance horses. Methods A total of 20 healthy 3–9-years-old Jeju crossbreed mares (5.95 ± 2.24 year of age and 312.65 ± 13.59 kg of weight currently participating the endurance competition were used. The field tests selected for the experiment was gallop (approximately 8.3 m/s along the selected 2.5 km course (a natural forest trail, not artificial road; a closed loop course. The horses were divided into three groups according to their age; 3–4 years of age (G1, 3.29 ± 0.49 year, 6–7 years of age (G2, 6.42 ± 0.53, and 8–9 years of age (G3, 8.50 ± 0.55. The measurements times for the heart rate, blood lactate concentration, PCV, and Hb analysis were conducted before exercise (T0, shortly after exercise (T1, 15 min after exercise (T2, and 30 min after exercise (T3, respectively. Data was analyzed using an analysis of covariance (ANCOVA for repeated measures with times and groups. Results The results of the comparison depending on the passage of rest time after exercise suggest that the heart rate and blood lactate concentration of three groups at T2 significantly decreased compared to T1 (p < 0.001. PCV of the G2 and G3 groups were significantly decreased at T2 compared to T1 (p < 0.01. Hb values at G2 (p < 0.01 and G3 (p < 0.001 groups were significantly decreased at T2 as compared to T1. However, heart rate, blood lactate concentration, PCV and Hb level at T1 showed no difference in the comparison of horses from different age groups with the exception of G3 group in terms of heart rate. Conclusion The physiologic and hematological responses of horses during recovery time after 2,500 m exercise with gallop were no significant difference among the groups. These data are useful as a response evaluation method for

  16. The effect of lipid emulsion of different concentration on blood flow velocity: an experimental study

    International Nuclear Information System (INIS)

    Li Qiang; Wang Maoqiang; Duan Liuxin; Song Peng; Ao Guokun

    2009-01-01

    Objective: To investigate the function mechanism of lipid emulsion (LE), used as a carrier, by observing the effect of intra-arterial infusion of LE in different concentration and dosage on blood flow velocity. Methods: According to the concentration and dosage used in arterial infusion, the experiments were divided into four groups:group A (20% LE, 2 ml), group B (20% LE, 20 ml), group C (30% LE, 2 ml) and group D (30% LE, 20 ml). Two healthy hybrid dogs were used for the study. Under DSA guidance, the 4 F catheter was placed in the splenic artery and in the hepatic artery respectively. DSA frames were counted in order to calculate the time that the contrast took from the catheter tip to the selected tertiary branches of the splenic or hepatic artery. Results LE infusion, regardless of its concentration level or its dosage, could reduce the blood velocity. The lasting time and the maximal peak value of the blood velocity reduction were significantly different among groups (P < 0.05). The lasting time was 5 minutes, 5-10 minutes, 20 minutes and 20-30 minutes among group A, B, C and D, respectively. The peak value of the reduction appeared at the 18th frames (1.44 s), 30th frames (2.4 s), 9th frames (0.9 s) and 14th frames (1.12 s) in group A, B, C and D, respectively. Conclusion Intra-arterial infusion of LE can reduce the blood flow velocity. The lasting time of the reduction in 30% LE groups is longer than that in 20% LE groups, while the blood velocity reduction in 30% LE groups is less than that in 20% LE groups. (authors)

  17. Lactate and ammonia concentration in blood and sweat during incremental cycle ergometer exercise

    NARCIS (Netherlands)

    Ament, W; Huizenga, [No Value; Mook, GA; Gips, CH; Verkerke, GJ

    It is known that the concentrations of ammonia and lactate in blood increase during incremental exercise. Sweat also contains lactate and ammonia. The aim of the present study was to investigate the physiological response of lactate and ammonia in plasma and sweat during a stepwise incremental cycle

  18. Decrease in Ionized and Total Magnesium Blood Concentrations in Endurance Athletes Following an Exercise Bout Restores within Hours-Potential Consequences for Monitoring and Supplementation.

    Science.gov (United States)

    Terink, Rieneke; Balvers, Michiel G J; Hopman, Maria T; Witkamp, Renger F; Mensink, Marco; Gunnewiek, Jacqueline M T Klein

    2017-06-01

    Magnesium is essential for optimal sport performance, generating an interest to monitor its status in athletes. However, before measuring magnesium status in blood could become routine, more insight into its diurnal fluctuations and effects of exercise itself is necessary. Therefore, we measured the effect of an acute bout of exercise on ionized (iMg) and total plasma magnesium (tMg) in blood obtained from 18 healthy well-trained endurance athletes (age, 31.1 ± 8.1 yr.; VO 2max , 50.9 ± 7.5 ml/kg/min) at multiple time points, and compared this with a resting situation. At both days, 7 blood samples were taken at set time points (8:30 fasted, 11:00, 12:30, 13:30, 15:00, 16:00, 18:30). The control day was included to correct for a putative diurnal fluctuation of magnesium. During the exercise day, athletes performed a 90 min bicycle ergometer test (70% VO 2max ) between 11:00 and 12:30. Whole blood samples were analyzed for iMg and plasma for tMg concentrations. Both concentrations decreased significantly after exercise (0.52 ± 0.04-0.45 ± 0.03 mmol/L and 0.81 ± 0.07-0.73 ± 0.06 mmol/L, respectively, p exercise. These findings suggest that timing of blood sampling to analyze Mg status is important. Additional research is needed to establish the recovery time after different types of exercise to come to a general advice regarding the timing of magnesium status assessment in practice.

  19. Blood harmane (1-methyl-9H-pyrido[3,4-b]indole) concentration in essential tremor cases in Spain.

    Science.gov (United States)

    Louis, Elan D; Benito-León, Julian; Moreno-García, Sara; Vega, Saturio; Romero, Juan Pablo; Bermejo-Pareja, Felix; Gerbin, Marina; Viner, Amanda S; Factor-Litvak, Pam; Jiang, Wendy; Zheng, Wei

    2013-01-01

    Environmental correlates for essential tremor (ET) are largely unexplored. The search for such environmental factors has involved the study of a number of neurotoxins. Harmane (1-methyl-9H-pyrido[3,4-b]indole) is a potent tremor-producing toxin. In two prior case-control studies in New York, we demonstrated that blood harmane concentration was elevated in ET patients vs. controls, and especially in familial ET cases. These findings, however, have been derived from a study of cases ascertained through a single tertiary referral center in New York. Our objective was to determine whether blood harmane concentrations are elevated in familial and sporadic ET cases, ascertained from central Spain, compared to controls without ET. Blood harmane concentrations were quantified by a well-established high performance liquid chromatography method. The median harmane concentrations were: 2.09 g(-10)/ml (138 controls), 2.41 g(-10)/ml (68 sporadic ET), and 2.90 g(-10)/ml (62 familial ET). In an unadjusted logistic regression analysis, log blood harmane concentration was not significantly associated with diagnosis (familial ET vs. control): odds ratio=1.56, p=0.26. In a logistic regression analysis that adjusted for evaluation start time, which was an important confounding variable, the odds ratio increased to 2.35, p=0.049. Blood harmane levels were slightly elevated in a group of familial ET cases compared to a group of controls in Spain. These data seem to further extend our observations from New York to a second cohort of ET cases in Spain. This neurotoxin continues to be a source of interest for future confirmatory research. Copyright © 2012 Elsevier Inc. All rights reserved.

  20. Advances towards reliable identification and concentration determination of rare cells in peripheral blood

    Science.gov (United States)

    Alemany Server, R.; Martens, D.; Jans, K.; Bienstman, P.; Hill, D.

    2016-03-01

    Through further development, integration and validation of micro-nano-bio and biophotonics systems FP7 CanDo is developing an instrument that will permit highly reproducible and reliable identification and concentration determination of rare cells in peripheral blood for two key societal challenges, early and low cost anti-cancer drug efficacy determination and cancer diagnosis/monitoring. A cellular link between the primary malignant tumour and the peripheral metastases, responsible for 90% of cancerrelated deaths, has been established in the form of circulating tumour cells (CTCs) in peripheral blood. Furthermore, the relatively short survival time of CTCs in peripheral blood means that their detection is indicative of tumour progression thereby providing in addition to a prognostic value an evaluation of therapeutic efficacy and early recognition of tumour progression in theranostics. In cancer patients however blood concentrations are very low (=1 CTC/1E9 cells) and current detection strategies are too insensitive, limiting use to prognosis of only those with advanced metastatic cancer. Similarly, problems occur in therapeutics with anti-cancer drug development leading to lengthy and costly trials often preventing access to market. The novel cell separation/Raman analysis technologies plus nucleic acid based molecular characterization of the CanDo platform will provide an accurate CTC count with high throughput and high yield meeting both key societal challenges. Being beyond the state of art it will lead to substantial share gains not just in the high end markets of drug discovery and cancer diagnostics but due to modular technologies also in others. Here we present preliminary DNA hybridization sensing results.

  1. Hepatitis B Virus Blood Screening: Need for Reappraisal of Blood Safety Measures?

    Directory of Open Access Journals (Sweden)

    Daniel Candotti

    2018-02-01

    Full Text Available Over the past decades, the risk of HBV transfusion–transmission has been steadily reduced through the recruitment of volunteer donors, the selection of donors based on risk-behavior evaluation, the development of increasingly more sensitive hepatitis B antigen (HBsAg assays, the use of hepatitis B core antibody (anti-HBc screening in some low-endemic countries, and the recent implementation of HBV nucleic acid testing (NAT. Despite this accumulation of blood safety measures, the desirable zero risk goal has yet to be achieved. The residual risk of HBV transfusion–transmission appears associated with the preseroconversion window period and occult HBV infection characterized by the absence of detectable HBsAg and extremely low levels of HBV DNA. Infected donations tested false-negative with serology and/or NAT still persist and derived blood components were shown to transmit the virus, although rarely. Questions regarding the apparent redundancy of some safety measures prompted debates on how to reduce the cost of HBV blood screening. In particular, accumulating data strongly suggests that HBsAg testing may add little, if any HBV risk reduction value when HBV NAT and anti-HBc screening also apply. Absence or minimal acceptable infectious risk needs to be assessed before considering discontinuing HBsAg. Nevertheless, HBsAg remains essential in high-endemic settings where anti-HBc testing cannot be implemented without compromising blood availability. HBV screening strategy should be decided according to local epidemiology, estimate of the infectious risk, and resources.

  2. Rapid Point of Care Analyzer for the Measurement of Cyanide in Blood

    Science.gov (United States)

    Ma, Jian; Ohira, Shin-Ichi; Mishra, Santosh K.; Puanngam, Mahitti; Dasgupta, Purnendu K.; Mahon, Sari B.; Brenner, Matthew; Blackledge, William; Boss, Gerry R.

    2011-01-01

    A simple, sensitive optical analyzer for the rapid determination of cyanide in blood in point of care applications is described. HCN is liberated by the addition of 20% H3PO4 and is absorbed by a paper filter impregnated with borate-buffered (pH 9.0) hydroxoaquocobinamide Hereinafter called cobinamide). Cobinamide on the filter changes color from orange (λmax = 510 nm) to violet (λmax = 583 nm) upon reaction with cyanide. This color change is monitored in the transmission mode by a light emitting diode (LED) with a 583 nm emission maximum and a photodiode detector. The observed rate of color change increases 10x when the cobinamide solution for filter impregnation is prepared in borate-buffer rather than in water. The use of a second LED emitting at 653 nm and alternate pulsing of the LEDs improve the limit of detection by 4x to ~ 0.5 μM for a 1 mL blood sample. Blood cyanide levels of imminent concern (≥ 10 μM) can be accurately measured in ~ 2 min. The response is proportional to the mass of cyanide in the sample – smaller sample volumes can be successfully used with proportionate change in the concentration LODs. Bubbling air through the blood-acid mixture was found effective for mixing of the acid with the sample and the liberation of HCN. A small amount of ethanol added to the top of the blood was found to be the most effective means to prevent frothing during aeration. The relative standard deviation (RSD) for repetitive determination of blood samples containing 9 μM CN was 1.09% (n=5). The technique was compared blind with a standard microdiffusion-spectrophotometric method used for the determination of cyanide in rabbit blood. The results showed good correlation (slope 1.05, r2 0.9257); independent calibration standards were used. PMID:21553921

  3. Automated Office Blood Pressure Measurement.

    Science.gov (United States)

    Myers, Martin G

    2018-04-01

    Manual blood pressure (BP) recorded in routine clinical practice is relatively inaccurate and associated with higher readings compared to BP measured in research studies in accordance with standardized measurement guidelines. The increase in routine office BP is the result of several factors, especially the presence of office staff, which tends to make patients nervous and also allows for conversation to occur. With the disappearance of the mercury sphygmomanometer because of environmental concerns, there is greater use of oscillometric BP recorders, both in the office setting and elsewhere. Although oscillometric devices may reduce some aspects of observer BP measurement error in the clinical setting, they are still associated with higher BP readings, known as white coat hypertension (for diagnosis) or white coat effect (with treated hypertension). Now that fully automated sphygmomanometers are available which are capable of recording several readings with the patient resting quietly, there is no longer any need to have office staff present when BP is being recorded. Such readings are called automated office blood pressure (AOBP) and they are both more accurate than conventional manual office BP and not associated with the white coat phenomena. AOBP readings are also similar to the awake ambulatory BP and home BP, both of which are relatively good predictors of cardiovascular risk. The available evidence suggests that AOBP should now replace manual or electronic office BP readings when screening patients for hypertension and also after antihypertensive drug therapy is initiated. Copyright © 2018. The Korean Society of Cardiology.

  4. Essential and toxic element concentrations in blood and urine and their associations with diet: Results from a Norwegian population study including high-consumers of seafood and game

    Energy Technology Data Exchange (ETDEWEB)

    Birgisdottir, B.E.; Knutsen, H.K.; Haugen, M.; Gjelstad, I.M. [Division of Environmental Medicine, Norwegian Institute of Public Health, Oslo (Norway); Jenssen, M.T.S. [Norwegian Institute for Water Research, Oslo (Norway); Ellingsen, D.G.; Thomassen, Y. [National Institute of Occupational Health, Oslo (Norway); Alexander, J. [Office of the Director-General, Norwegian Institute of Public Health, Oslo (Norway); Meltzer, H.M. [Division of Environmental Medicine, Norwegian Institute of Public Health, Oslo (Norway); Brantsæter, A.L., E-mail: Anne.Lise.Brantsaeter@fhi.no [Division of Environmental Medicine, Norwegian Institute of Public Health, Oslo (Norway)

    2013-10-01

    The first aim of the study was to evaluate calculated dietary intake and concentrations measured in blood or urine of essential and toxic elements in relation to nutritional and toxicological reference values. The second aim was to identify patterns of the element concentrations in blood and urine and to identify possible dietary determinants of the concentrations of these elements. Adults with a known high consumption of environmental contaminants (n = 111), and a random sample of controls (n = 76) answered a validated food frequency questionnaire (FFQ). Complete data on biological measures were available for 179 individuals. Blood and urine samples were analyzed for selenium, iodine, arsenic, mercury, cadmium and lead. Principal component analysis was used to identify underlying patterns of correlated blood and urine concentrations. The calculated intakes of selenium, iodine, inorganic arsenic and mercury were within guideline levels. For cadmium 24% of the high consumer group and 8% of the control group had intakes above the tolerable weekly intake. Concentrations of lead in blood exceeded the bench-mark dose lower confidence limits for some participants. However, overall, the examined exposures did not give rise to nutritional or toxicological concerns. Game consumption was associated with lead in blood (B{sub ln} 0.021; 95%CI:0.010, 0.031) and wine consumption. Seafood consumption was associated with urinary cadmium in non-smokers (B{sub ln} 0.009; 95%CI:0.003, 0.015). A novel finding was a distinct pattern of positively associated biological markers, comprising iodine, selenium, arsenic and mercury (eigenvalue 3.8), reflecting seafood intake (B 0.007; 95%CI:0.004, 0.010). The study clearly demonstrates the significance of seafood as a source of both essential nutrients and toxic elements simultaneously and shows that exposure to various essential and toxic elements can be intertwined. - Highlights: • A study on interplay and sources of six different

  5. Essential and toxic element concentrations in blood and urine and their associations with diet: Results from a Norwegian population study including high-consumers of seafood and game

    International Nuclear Information System (INIS)

    Birgisdottir, B.E.; Knutsen, H.K.; Haugen, M.; Gjelstad, I.M.; Jenssen, M.T.S.; Ellingsen, D.G.; Thomassen, Y.; Alexander, J.; Meltzer, H.M.; Brantsæter, A.L.

    2013-01-01

    The first aim of the study was to evaluate calculated dietary intake and concentrations measured in blood or urine of essential and toxic elements in relation to nutritional and toxicological reference values. The second aim was to identify patterns of the element concentrations in blood and urine and to identify possible dietary determinants of the concentrations of these elements. Adults with a known high consumption of environmental contaminants (n = 111), and a random sample of controls (n = 76) answered a validated food frequency questionnaire (FFQ). Complete data on biological measures were available for 179 individuals. Blood and urine samples were analyzed for selenium, iodine, arsenic, mercury, cadmium and lead. Principal component analysis was used to identify underlying patterns of correlated blood and urine concentrations. The calculated intakes of selenium, iodine, inorganic arsenic and mercury were within guideline levels. For cadmium 24% of the high consumer group and 8% of the control group had intakes above the tolerable weekly intake. Concentrations of lead in blood exceeded the bench-mark dose lower confidence limits for some participants. However, overall, the examined exposures did not give rise to nutritional or toxicological concerns. Game consumption was associated with lead in blood (B ln 0.021; 95%CI:0.010, 0.031) and wine consumption. Seafood consumption was associated with urinary cadmium in non-smokers (B ln 0.009; 95%CI:0.003, 0.015). A novel finding was a distinct pattern of positively associated biological markers, comprising iodine, selenium, arsenic and mercury (eigenvalue 3.8), reflecting seafood intake (B 0.007; 95%CI:0.004, 0.010). The study clearly demonstrates the significance of seafood as a source of both essential nutrients and toxic elements simultaneously and shows that exposure to various essential and toxic elements can be intertwined. - Highlights: • A study on interplay and sources of six different elements • The

  6. Surface dust wipes are the best predictors of blood leads in young children with elevated blood lead levels

    Energy Technology Data Exchange (ETDEWEB)

    Gulson, Brian, E-mail: brian.gulson@mq.edu.au [Graduate School of the Environment, Macquarie University, North Ryde NSW 2109 (Australia); CSIRO Earth Science and Resource Engineering, North Ryde NSW 2113 (Australia); Anderson, Phil [Information and Statistics Group, Australian Institute of Health and Welfare, Canberra ACT 2601 (Australia); Faculty of Health, University of Canberra, Canberra ACT 2601 (Australia); Taylor, Alan [Department of Psychology, Macquarie University, Sydney NSW 2109 (Australia)

    2013-10-15

    Background: As part of the only national survey of lead in Australian children, which was undertaken in 1996, lead isotopic and lead concentration measurements were obtained from children from 24 dwellings whose blood lead levels were ≥15 µg/dL in an attempt to determine the source(s) of their elevated blood lead. Comparisons were made with data for six children with lower blood lead levels (<10 µg/dL). Methods: Thermal ionisation and isotope dilution mass spectrometry were used to determine high precision lead isotopic ratios ({sup 208}Pb/{sup 206}Pb, {sup 207}Pb/{sup 206}Pb and {sup 206}Pb/{sup 204}Pb) and lead concentrations in blood, dust from floor wipes, soil, drinking water and paint (where available). Evaluation of associations between blood and the environmental samples was based on the analysis of individual cases, and Pearson correlations and multiple regression analyses based on the whole dataset. Results and discussion: The correlations showed an association for isotopic ratios in blood and wipes (r=0.52, 95% CI 0.19–0.74), blood and soil (r=0.33, 95% CI −0.05–0.62), and blood and paint (r=0.56, 95% CI 0.09–0.83). The regression analyses indicated that the only statistically significant relationship for blood isotopic ratios was with dust wipes (B=0.65, 95% CI 0.35–0.95); there were no significant associations for lead concentrations in blood and environmental samples. There is a strong isotopic correlation of soils and house dust (r=0.53, 95% CI 0.20–0.75) indicative of a common source(s) for lead in soil and house dust. In contrast, as with the regression analyses, no such association is present for bulk lead concentrations (r=−0.003, 95% CI −0.37–0.36), the most common approach employed in source investigations. In evaluation of the isotopic results on a case by case basis, the strongest associations were for dust wipes and blood. -- Highlights: • Children with elevated blood lead ≥15 µg/dL compared with a group with <10

  7. Effect of prenatal exposure to different salt concentration on the third month's weight and blood pressure in wistar rat

    International Nuclear Information System (INIS)

    Fereidoun, H.

    2009-01-01

    In utero alterations in fluid and electrolyte endocrine systems may result in permanent effects on offspring. A low sodium intake during prenatal life jeopardizes growth in young rats, prenatal high-salt diet in Sprague-Dawley rats caused an increase in MAP at postnatal day 30. The objective of this study was to determine the effect of prenatal exposure to different salt concentrations on the third month's weight and blood pressure in Wistar rat. This study was performed at the Department of Physiology, Isfahan University of Medical Science, Isfahan, Iran, over a period from 1998 to 2003. Six groups of rat, 1 male and 5 female in each group were exposed to 0.5, 1, 1.4, 1.6, 1.8 and 2 percent of salt concentrations during pre-pregnancy, pregnancy and lactation period, another test group consumed distilled water and control group used Isfahan tap water, other living conditions for all groups were similar. Exposure to different salt concentrations on the third month's weight and blood pressure was evaluated. Prenatal exposure to 0.5 and 1% salt concentrations gives birth to more alive and healthy infants, and third month's weight increased significantly, but blood pressure was not influenced significantly. Salt concentrations higher than 1% increased the maternal and infant mortality rate and blood pressure significantly, but some concentrations decreased third month's weight significantly. Level of dietary salt during intrauterine development can influence on the number of alive and healthy infants, birth weight, third month' weight and blood pressure significantly. There is no need to introduce a salt restricted diet in prenatal care, a balanced diet in sodium during pregnancy is recommended, high salt diet creates harmful effect. (author)

  8. Blood (Breath) Alcohol Concentration Rates of College Football Fans on Game Day

    Science.gov (United States)

    Glassman, Tavis; Braun, Robert; Reindl, Diana M.; Whewell, Aubrey

    2011-01-01

    The purpose of this study was to determine the Blood (breath) Alcohol Concentration (BrAC) rates of college football fans on game day. Researchers employed a time-series study design, collecting data at home football games at a large university in the Midwest. Participants included 536 individuals (64.4% male) ages 18-83 (M = 28.44, SD = 12.32).…

  9. Blood cell labeling with technetium-99m. II. Measurement of circulating blood volume by sup(99m)Tc-labeled red blood cells

    Energy Technology Data Exchange (ETDEWEB)

    Uchida, T; Yoshida, H; Matsuda, S; Kimura, H; Miura, N [Fukushima Medical Coll. (Japan)

    1978-02-01

    Using a labeling method with sup(99m)Tc-pertechnetate to red blood cells (RBC), circulating blood volume was measured in comparison with that from /sup 51/Cr-labeled RBC method. The technique is easier than already published methods, because CIS kit for sup(99m)Tc-RBC labeling (TCK-11) became to be available recently. Two mls of ACD-anticoagulated blood were withdrawn and 0.5 ml of reducing reagent prepared just before use was added to blood, waiting 5 minutes and discarding the serum after centrifugation, then adding 100 ..mu..Ci of sup(99m)Tc. After washing the labeled cells by isotonic saline, cells were re-suspended in 10 ml of saline and injected to the subject. Blood specimen was obtained 10, 30, 60 and 120 minutes after infusion and blood volume was calculated by the usual way. Circulating blood volume by sup(99m)Tc was well correlated with that by /sup 51/Cr (=0.98, p 0.01), however, the value calculated from sup(99m)Tc were 4.8 percent higher than those by /sup 51/Cr, which suggested the elution of sup(99m)Tc from labeled RBC. sup(99m)Tc method has the advantages that higher radioactivity can be obtained in small amount of blood, which is useful in the determination of blood volume in children or in small animals in the laboratory. The measurement of blood volume of the mouse was done by using sup(99m)Tc method. The results were 1.70 +- 0.06 ml (6.35 +- 0.18%/gm), which coincided with the values reported previously. Because of it's short half life and low radiation dosage to the patients, sup(99m)Tc method will be recommended in the field of pediatrics or in patients with polycythemia or congestive heart failure, who are requested the repeated measurement of blood volume.

  10. The effect of a standardized protocol for iron supplementation to blood donors low in hemoglobin concentration.

    Science.gov (United States)

    Magnussen, Karin; Bork, Nanna; Asmussen, Lisa

    2008-04-01

    Iron deficiency leading to low hemoglobin concentration (cHb) is a common problem for blood donors as well as for blood banks. A standardized protocol offering iron supplementation based on P-ferritin determination may help to reduce the problem and retain donors. This was a prospective study where 879 blood donors, presenting with cHb at or below the limit of acceptance for donation, were included. The predonation cHb result was read after donation. The donors received 50 iron tablets (JernC or Ferrochel, 100 or 25 mg elemental iron, respectively), and samples for P-ferritin, mean corpuscular volume, and control of cHb were secured. Based on a P-ferritin level of less than 60 microg per L, 20 iron tablets were offered after all following donations. Mean cHb was 7.6 mmol per L (122 g/L) and 8.2 mmol per L (132 g/L) in women and men, respectively. In 80 percent of the women and 48 percent of the men, iron stores were low (P-ferritin protocol offering iron supplementation and simple oral and written advice based on P-ferritin measurements is effective in normalizing cHb and retaining donors presenting with cHb at or below the limit of acceptance for donation.

  11. Immunocapture and microplate-based activity and quantity measurement of pyruvate dehydrogenase in human peripheral blood mononuclear cells

    Science.gov (United States)

    Liu, Xiaowen; Pervez, Hira; Andersen, Lars W; Uber, Amy; Montissol, Sophia; Patel, Parth; Donnino, Michael W

    2015-01-01

    Background Pyruvate dehydrogenase (PDH) activity is altered in many human disorders. Current methods require tissue samples and yield inconsistent results. We describe a modified method for measuring PDH activity from isolated human peripheral blood mononuclear cells (PBMCs). Results/Methodology We found that PDH activity and quantity can be successfully measured in human PBMCs. Freeze-thaw cycles cannot efficiently disrupt the mitochondrial membrane. Processing time of up to 20 h does not affect PDH activity with proteinase inhibitor addition and a detergent concentration of 3.3% showed maximum yield. Sample protein concentration is correlated to PDH activity and quantity in human PBMCs from healthy subjects. Conclusion Measuring PDH activity from PBMCs is a novel, easy and less invasive way to further understand the role of PDH in human disease. PMID:25826140

  12. Concentrations of Polychlorinated Biphenyls and Organochlorine Pesticides in Umbilical Cord Blood Serum of Newborns in Kingston, Jamaica

    Directory of Open Access Journals (Sweden)

    Mohammad H. Rahbar

    2016-10-01

    Full Text Available To date much of the biomonitoring related to exposure to polychlorinated biphenyls (PCBs and organochlorine (OC pesticides is from middle to high income countries, including the U.S., Canada and Europe, but such data are lacking for the majority of low to middle income countries. Using data from 64 pregnant mothers who were enrolled in 2011, we aimed to assess the concentrations of the aforementioned toxins in umbilical cord blood serum of 67 Jamaican newborns. For 97 of the 100 PCB congeners and 16 of the 17 OC pesticides, all (100% concentrations were below their respective limits of detection (LOD. Mean (standard deviation (SD lipid-adjusted concentrations in cord blood serum for congeners PCB-153, PCB-180, PCB-206 and total PCB were 14.25 (3.21, 7.16 (1.71, 7.30 (1.74 and 28.15 (6.03 ng/g-lipid, respectively. The means (SD for the 4,4′-dichlorodiphenyldichloroethylene (DDE-hexane fraction and total-DDE were 61.61 (70.78 and 61.60 (70.76 ng/g-lipid, respectively. Compared to the U.S. and Canada, the concentrations of these toxins were lower in cord-blood serum of Jamaican newborns. We discuss that these differences could be partly due to differences in dietary patterns in these countries. Despite limitations in our dataset, our results provide information on the investigated toxins in cord blood serum that could serve as a reference for Jamaican newborns.

  13. Absorption and peak blood alcohol concentration after drinking beer, wine, or spirits.

    Science.gov (United States)

    Mitchell, Mack C; Teigen, Erin L; Ramchandani, Vijay A

    2014-05-01

    Both the amount and the rate of absorption of ethanol (EtOH) from alcoholic beverages are key determinants of the peak blood alcohol concentration (BAC) and exposure of organs other than gut and liver. Previous studies suggest EtOH is absorbed more rapidly in the fasting than in the postprandial state. The concentration of EtOH and the type of beverage may determine gastric emptying/absorption of EtOH. The pharmacokinetics of EtOH were measured in 15 healthy men after consumption of 0.5 g of EtOH/kg body weight. During this 3-session crossover study, subjects consumed in separate sessions, beer (5.1% v/v), white wine (12.5% v/v), or vodka/tonic (20% v/v) over 20 minutes following an overnight fast. BAC was measured by gas chromatography at multiple points after consumption. Peak BAC (Cmax ) was significantly higher (p wine (61.7 ± 10.8 mg/dl) or beer (50.3 ± 9.8 mg/dl) and was significantly higher (p wine than beer. The time to Cmax occurred significantly earlier (p wine (54 ± 14 minutes) or beer (62 ± 23 minutes). Six subjects exceeded a Cmax of 80 mg/dl after vodka/tonic, but none exceeded this limit after beer or wine. The area under the concentration-time curve (AUC) was significantly greater after drinking vodka/tonic (p wine or beer. Comparison of AUCs indicated the relative bioavailability of EtOH was lower after drinking beer. Findings indicate that BAC is higher after drinking vodka/tonic than beer or wine after fasting. A binge pattern is significantly more likely to result in BAC above 80 mg/dl after drinking vodka/tonic than beer or wine. Men drinking on an empty stomach should know BAC will vary depending on beverage type and the rate and amount of EtOH. © 2014 The Authors. Alcoholism: Clinical and Experimental Research published by Wiley Periodicals, Inc. on behalf of Research Society on Alcoholism.

  14. Measurement of regional hepatic blood flow by scintiphotosplenoportography

    Energy Technology Data Exchange (ETDEWEB)

    Kashiwagi, T; Kimura, K; Kamada, T; Abe, H [Osaka Univ. (Japan). Dept. of Radiology and Nuclear Medicine

    1978-08-01

    A new technique for estimating regional hepatic blood flow using the inert gas washout technique and scintillation camera following injection of /sup 133/Xe into the spleen is presented. This technique is easily, rapidly and repeatedly performed and permits the measurement of nutrient hepatic tissue blood flow. Measurement of regional hepatic blood flow in right and/or left lobes was performed in 28 patients. In all but one patient the right lobar flow value was equal to or greater than the left one. The right lobar flow was 86.20 +- 12.83 ml/100 gm/min in 3 patients without liver disease, 75.12 +- 14.54 ml/100 gm/min in 12 with chronic hepatitis and 51.24 +- 17.13 ml/100 gm/min in 11 with liver cirrhosis. This result suggests that hepatic tissue blood flow is significantly decreased in patients with liver cirrhosis. Scintillation camera images of initial xenon distribution in combination with monitor of washout curves over the liver also provide more information on the presence of extra- and intrahepatic shunts. Therefore, this technique appears to be clinically useful in evaluation of hemodynamic phenomena associated with liver diseases.

  15. Critical Evaluation of Blood Volume Measurements during Hemodialysis

    NARCIS (Netherlands)

    Dasselaar, Judith J.; van der Sande, Frank M.; Franssen, Casper F. M.

    2012-01-01

    Devices that continuously measure relative blood volume (RBV) changes during hemodialysis (HD) are increasingly used for the prevention of dialysis hypotension and fine-tuning of dry weight. However, RBV measurements are subject to various limitations. First, RBV devices provide information on

  16. Changes of very low-density lipoprotein concentration in hepatic blood from cows with fasting-induced hepatic lipidosis.

    Science.gov (United States)

    Oikawa, Shin; Mizunuma, Yuko; Iwasaki, Yukari; Tharwat, Mohamed

    2010-10-01

    The purpose of this study was to evaluate changes of very low-density lipoprotein (VLDL) components in hepatic blood (HB) from 5 nonlactating nonpregnant cows fasted from days 0 to 3 and subsequently refed to day 10 and, in addition, to assess those of other lipoproteins. Increased phospholipid concentrations in each lipoprotein after the start of fasting suggested their availability for the surface lipids of lipoproteins. Although the VLDL-triglyceride (TG) concentration in HB from all cows increased on day 1, the value on day 4 became similar to that on day 0. However, the concentration on day 10 was significantly increased. In all cows, the decreased ratio of the VLDL-TG concentration in HB to the non-esterified fatty acids (NEFA) concentration in portal blood (PB) on day 4 appeared to reflect relatively decreased secretion of TG as VLDL by NEFA excessively mobilized to the liver via PB. The markedly increased ratio on day 10 was considered to contribute to the improvement of hepatic lipidosis.

  17. Determination of lead and zinc concentrations in the blood and liver of the captive common green iguana (Iguana iguana).

    Science.gov (United States)

    Burns, Russell P; Paul-Murphy, Joanne

    2009-09-01

    Heavy metal toxicosis is a well-known phenomenon in wild, captive-animal, and domestic animal medicine. However, the occurrence among reptiles is not well documented. One reason for this is the lack of information regarding reference blood and tissue levels of heavy metals in reptiles. To determine normal blood lead, plasma zinc, and liver lead and zinc concentrations, blood and liver samples were collected from 4 adult and 16 juvenile, healthy green iguanas (Iguana iguana). Lead and zinc levels were measured using atomic absorption spectroscopy. Using the mean +/- two SD as the normal reference range, the present study suggests the following for captive common green iguana: 1) whole blood lead level: 0.06 +/- 0.06 microg/ml; 2) plasma zinc level: 2.68 +/- 1.66 microg/ml; 3) liver lead level (wet-weight basis): <1.0 +/- 0.0 microg/g; 4) liver lead level (dry-weight basis): <3.0 +/- 0.0 microg/g; 5) liver zinc level (wet-weight basis): 24.9 +/- 11.6 microg/g; and 6) liver zinc level (dry-weight basis): 83.4 +/- 44.6 microg/g. These values are fairly consistent with published reference levels in other mammalian and avian species.

  18. Saliva oxytocin measures do not reflect peripheral plasma concentrations after intranasal oxytocin administration in men.

    Science.gov (United States)

    Quintana, Daniel S; Westlye, Lars T; Smerud, Knut T; Mahmoud, Ramy A; Andreassen, Ole A; Djupesland, Per G

    2018-05-16

    Oxytocin plays an important role in social behavior. Thus, there has been significant research interest for the role of the oxytocin system in several psychiatric disorders, and the potential of intranasal oxytocin administration to treat social dysfunction. Measurement of oxytocin concentrations in saliva are sometimes used to approximate peripheral levels of oxytocin; however, the validity of this approach is unclear. In this study, saliva and plasma oxytocin was assessed after two doses of Exhalation Delivery System delivered intranasal oxytocin (8 IU and 24 IU), intravenous oxytocin (1 IU) and placebo in a double-dummy, within-subjects design with men. We found that intranasal oxytocin (8 IU and 24 IU) administration increased saliva oxytocin concentrations in comparison to saliva oxytocin concentration levels after intravenous and placebo administration. Additionally, we found that saliva oxytocin concentrations were not significantly associated with plasma oxytocin concentrations after either intranasal or intravenous oxytocin administration. Altogether, we suggest that saliva oxytocin concentrations do not accurately index peripheral oxytocin after intranasal or intravenous oxytocin administration, at least in men. The data indicates that elevated oxytocin saliva levels after nasal delivery primarily reflect exogenous administered oxytocin that is cleared from the nasal cavity to the oropharynx, and is therefore a weak surrogate for peripheral blood measurements. Copyright © 2018 Elsevier Inc. All rights reserved.

  19. Ammonia concentration and bacterial evaluation of feline whole blood and packed red blood cell units stored for transfusion

    Directory of Open Access Journals (Sweden)

    Eva Spada

    2014-10-01

    Full Text Available Ammonia concentrations increase in human, canine and equine WB and PRBC units during storage. The aim of this study was to determine the effect of storage on ammonia concentration in feline WB and PRBC units stored in a veterinary blood bank and to evaluate possible correlations with bacterial contamination. Ammonia concentration was evaluated in 15 WB units and 2 PRBC units on day 1 and at the end of storage after 35 and 42 days, respectively. In an additional 5 WB units and 4 PRBC units ammonia concentrations were determined daily until the day the normal reference range was exceeded and then weekly to the end of storage. All units were evaluated for bacterial contamination. Ammonia increased markedly during storage as a linear function over time. On the 35th and 42th day of storage at 4±2°C mean±SD ammonia concentration reached 909±158 µg/dl and 1058±212 µg/dl in WB and PRBC units, respectively. Bacterial culture was negative in all units. High ammonia concentrations in stored WB and PRBC units could result in toxicity, particularly in feline recipients with liver failure, portosystemic shunts or those receiving large transfusion volumes. Clinical in vivo studies evaluating the effects on recipients should be performed.

  20. Contribution of dietary patterns to blood heavy metal concentrations in Korean adults: findings from the Fifth Korea National Health and Nutrition Examination Survey 2010.

    Science.gov (United States)

    Chung, Hye-Kyung; Park, Ju Yeon; Cho, Yoonsu; Shin, Min-Jeong

    2013-12-01

    The aim of the present study was to evaluate the associations between dietary patterns and blood levels of lead and mercury in Korean adults. A total of 858 Korean adults (≥20 years) who participated in the Korea National Health and Nutrition Examination Survey (KNHANES) V-1 2010 were included in this study. Data of biochemical measurements including blood lead and mercury levels, nutrients intakes and anthropometric measurements were acquired. 'Balanced diet', 'Grain and kimchi', and 'Alcohol and noodle' dietary patterns were derived from a factor analysis, and the subjects were divided into tertiles by each dietary pattern score. A logistic multiple regression analysis showed that the balanced diet pattern was negatively associated with blood levels of lead before and after adjustment. On the other hand, the alcohol and noodle pattern was positively associated with blood lead and mercury levels. These results indicate that the alcohol and noodle dietary pattern characterized by high alcohol consumption and lack of various foods, and the balanced dietary pattern, including vegetable, fish, meat and milk intake, was associated with the blood concentrations of heavy metals in Korean adults. Copyright © 2013 Elsevier Ltd. All rights reserved.

  1. [Changes in the blood concentrations of interleukins and electrolytes in miners working in deep coal mines].

    Science.gov (United States)

    Belkina, E B; Rebrov, B A; Rebrova, O A; Stroilo, N G; Voloshinovich, A R

    2001-01-01

    Miners working in deep coal mines, engaged in hard physical work under most harsh mine conditions demonstrate a striking imbalance between pro- and antiinflammatory cytokines and a rise in the blood levels of electrolytes K+ and Na+ as well. The analysis performed revealed a direct correlation between the level of blood concentration of IL-6 and that of K+, Na+.

  2. Blind Deconvolution for Distributed Parameter Systems with Unbounded Input and Output and Determining Blood Alcohol Concentration from Transdermal Biosensor Data.

    Science.gov (United States)

    Rosen, I G; Luczak, Susan E; Weiss, Jordan

    2014-03-15

    We develop a blind deconvolution scheme for input-output systems described by distributed parameter systems with boundary input and output. An abstract functional analytic theory based on results for the linear quadratic control of infinite dimensional systems with unbounded input and output operators is presented. The blind deconvolution problem is then reformulated as a series of constrained linear and nonlinear optimization problems involving infinite dimensional dynamical systems. A finite dimensional approximation and convergence theory is developed. The theory is applied to the problem of estimating blood or breath alcohol concentration (respectively, BAC or BrAC) from biosensor-measured transdermal alcohol concentration (TAC) in the field. A distributed parameter model with boundary input and output is proposed for the transdermal transport of ethanol from the blood through the skin to the sensor. The problem of estimating BAC or BrAC from the TAC data is formulated as a blind deconvolution problem. A scheme to identify distinct drinking episodes in TAC data based on a Hodrick Prescott filter is discussed. Numerical results involving actual patient data are presented.

  3. The position of the arm during blood pressure measurement in sitting position.

    Science.gov (United States)

    Adiyaman, Ahmet; Verhoeff, Rutger; Lenders, Jacques W M; Deinum, Jaap; Thien, Theo

    2006-12-01

    Determining the influence of the position of the arm on blood pressure measurement in the sitting position. Blood pressure of 128 individuals (the majority being treated hypertensive patients) visiting the outpatient clinic was measured simultaneously on both arms with arms in two different positions. First, both arms were placed at the chair support level and blood pressure was measured three times on both arms after 10 min of rest. Subsequently, while still remaining in the same sitting position, five blood pressure measurements were made simultaneously at both arms with one arm placed on the desk and one arm placed and supported at heart level (mid-sternal). The arm placed at heart level served as the reference arm. The choice of which arm was placed at desk level and which arm was placed at heart level was randomized. Both at desk level and at chair support level, mean (+/-SD) systolic and diastolic blood pressures were higher than blood pressure at heart level by 6.1/5.7+/-4.6/3.1 and 9.3/9.4+/-5.4/3.4 mmHg, respectively. The effect of the height differences between the arm positions on the blood pressure readings was smaller than predicted (0.49 mmHg/cm systolic and 0.47 mmHg/cm diastolic). No significant correlation was found between blood pressure difference in the different arm positions (desk and heart level) and age, sex, weight or baseline blood pressure. Different arm positions below heart level have significant effects on blood pressure readings. The leading guidelines about arm position during blood pressure measurement are not in accordance with the arm position used in the Framingham study, the most frequently used study for risk estimations.

  4. Association between secondhand smoke exposure and blood lead and cadmium concentration in community dwelling women: the fifth Korea National Health and Nutrition Examination Survey (2010-2012).

    Science.gov (United States)

    Jung, Se Young; Kim, Suyeon; Lee, Kiheon; Kim, Ju Young; Bae, Woo Kyung; Lee, Keehyuck; Han, Jong-Soo; Kim, Sarah

    2015-07-16

    To assess the association between secondhand smoke exposure and blood lead and cadmium concentration in women in South Korea. Population-based cross-sectional study. South Korea (Korea National Health and Nutrition Examination Survey V). 1490 non-smoking women who took part in the fifth Korea National Health and Nutrition Examination Survey (2010-2012), in which blood levels of lead and cadmium were measured. The primary outcome was blood levels of lead and cadmium in accordance with the duration of secondhand smoke exposure. The adjusted mean level of blood cadmium in women who were never exposed to secondhand smoke was 1.21 (0.02) µg/L. Among women who were exposed less than 1 h/day, the mean cadmium level was 1.13 (0.03) µg/L, and for those exposed for more than 1 h, the mean level was 1.46 (0.06) µg/L. In particular, there was a significant association between duration of secondhand smoke exposure at the workplace and blood cadmium concentration. The adjusted mean level of blood cadmium concentration in the never exposed women's group was less than that in the 1 h and more exposed group, and the 1 h and more at workplace exposed group: 1.20, 1.24 and 1.50 µg/L, respectively. We could not find any association between lead concentration in the blood and secondhand smoke exposure status. This study showed that exposure to secondhand smoke and blood cadmium levels are associated. Especially, there was a significant association at the workplace. Therefore, social and political efforts for reducing the exposure to secondhand smoke at the workplace are needed in order to promote a healthier working environment for women. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  5. Impact of Biological Feedback and Incentives on Blood Fatty Acid Concentrations, Including Omega-3 Index, in an Employer-Based Wellness Program.

    Science.gov (United States)

    McBurney, Michael I; Bird, Julia K

    2017-08-05

    Eicosapentaenoic acid (EPA, C20:5n-3) and docosahexaenoic acid (DHA, C22:6n-3) are important fatty acids for the retina and brain. More than 95% of Americans have suboptimal EPA + DHA blood concentrations. This cross-sectional employer-based study assessed whole blood fatty acid levels of volunteers participating in an onsite wellness biometric screening program and was designed to determine if an incentive, a $5 coupon for a 90-day supply of fish oil supplement typically costing $18-30, stimulated incremental dietary behavior change relative to nutritional status assessment alone to increase EPA + DHA concentrations. Volunteers completed a dietary survey and finger stick blood samples were collected to be analyzed for fatty acid composition. In addition, 636 individuals participated in the initial onsite biometric screening. Three months later, and without prior knowledge, all employees were invited to a second screening. At the second screening, 198 employees volunteered for the first time and 149 employees had a second test (17.9%). At baseline, the average age ( n = 834) was 45 year and omega-3 index was 5.0% with 41% female. EPA + DHA concentration, i.e., omega-3 index, was significantly lower in men (4.8%) than women (5.2%), as were DHA and linoleic acid (LA) concentrations ( p omega-3 index was positively and linearly associated with omega-3 intake. Only 4% of volunteers had an omega-3 index >8% on initial screening. Among the 149 individuals with two measurements, omega-3 intake from supplements, but not food, increased significantly from 258 to 445 mg/d ( p omega-3 index (+0.21, p omega-3 supplement.

  6. Blood pressure self-measurement in the obstetric waiting room

    DEFF Research Database (Denmark)

    Wagner, Stefan; Kamper, Christina H.; Toftegaard, Thomas Skjødeberg

    2013-01-01

    a reliable blood pressure reading. Results: We found that the patients did not adhere to given instructions when performing blood pressure self-measurement in the waiting room. None of the 81 patients adhered to all six inves- tigated recommendations, while around a quarter adhered to five out of six...

  7. Cerebral distribution of 133Xe and blood flow measured with high purity germanium

    International Nuclear Information System (INIS)

    Reich, T.; Rusinek, H.; Youdin, M.; Clagnaz, M.

    1985-01-01

    Distribution of cerebral blood flow was measured with an array of 200 ultra-pure germanium radiation detectors and 133 Xe by inhalation. The array sees the head as a composite of different subvolumes and enables measurement of the concentration history of tracer every 1-10 sec in each subvolume simultaneously. Subvolume mean flows, (fm), and partition coefficients, lambda m, are derived by compartmental analysis of tissue concentration washout curves. Errors from cross talk, scalp radiation, look through, and assumed partition coefficients are eliminated. Average fm adjusted for 40 mm Hg PACO 2 in 14 cortical subvolumes (7 right, 7 left) of four normal 21-24 year old controls ranged from 50 to 60 ml/100 cc tissue/min, and lambda m ranged from 0.97 to 1.14. Average fm and lambda m in white matter was 24 ml/100 cc/min and 1.42 - 1.14 respectively. During CO 2 inhalation, right and left hemispheric fm increased 6.4% and 5.7%/mm Hg respectively, whereas white matter fm increased 2.2% and 3.4% mm Hg respectively. There was no systematic difference between front and back or dominant vs non-dominant sides. Three 73-84 year old controls had reduced fm and CO 2 reactivity in all subvolumes, lambda m was in the same range as in younger controls. Two patients with intracranial cerebrovascular disease showed excellent localization of ischemic subvolumes. One patient with asymptomatic unilateral 98% stenosis of the internal carotid artery had a similar distribution of blood flow in both hemispheres

  8. Measurement of Finger Blood Flow in Raynauds Phenomenon by Radionuclide Angiography

    International Nuclear Information System (INIS)

    Lim, Sang Moo; Chung, June Key; Lee, Myung Chul; Kim, Sang Joon; Choi, Sung Jae; Koh, Chang Soon

    1987-01-01

    In Raynauds phenomenon, the authors measured finger blood flow after ice water exposure by analyzing the time activity curve of radionuclide angiography on both hands. The results were as follows: 1) The digital blood flow did not decrease after ice water exposure in normal subjects. 2) In the patients with Raynauds phenomenon, there were two groups: the one had decreased digital blood flow after cold exposure, and the other had paradoxically increased digital blood flow after cold exposure. 3) There was no difference in the digital blood flow of hand in room temperature between the normal and the patients with reduced digital blood flow after cold exposure, but the digital blood flow of the hand in room temperature was markedly reduced in the patients with paradoxically increased flow after cold exposure. 4) In the static image the difference was not significant in comparison with the dynamic study, because it represents pooling of the blood in the vein rather than flow. 5) After the treatment with nifedipine, the digital blood flow increased. In conclusion, the radionuclide angiography was useful in measuring the digital blood flow in Raynauds phenomenon, and further studies with various drugs is expected.

  9. Effect of Low Dose Gamma Radiation Upon the Concentration of Calcium and Inorganic Phosphorus in the Blood Plasma of Chickens

    International Nuclear Information System (INIS)

    Kraljevic, P.; Vilic, M.; Miljanic, S.; Simpraga, M.

    2003-01-01

    In our previous paper it has been showed that the irradiation of chickens eggs before incubation by low dose gamma irradiation effects upon growth of the chickens hatched from irradiated eggs as well as upon activity of ALT and AST, and on the concentration of total proteins, glucose and cholesterol in the blood plasma of those chickens. Therefore in this paper an attempt was made to determine the effects of irradiation of eggs by low dose of ionizing radiation on the 19th day of incubation upon the concentration of calcium (Ca) and inorganic phosphorus (P) in the blood plasma of chickens hatched from irradiated eggs. The eggs of heavy breeding chickens (Gent, line COBB 500) were irradiated by a dose of 0.15 Gy gamma radiation (6 0C o source) on the 19th day of incubation. Along with the chickens, which were hatched from irradiated eggs, there was a control group of chickens hatched from nonirradiated eggs. All other conditions were the same for both groups. After hatching, blood samples were taken on day 1, 3, 5, 7, 10, 20, 30 and 42. The concentration of Ca was determined calorimetrically using Randox optimized kits, while the concentration of P was determined by Herbos dijagnostika Sisak (Croatia) optimized kits. The concentration of Ca in the blood plasma of chickens hatched from irradiated eggs was significantly increased on the first day, while it was decreased on the day 42. The concentration of P was decreased on the first day in blood plasma of chickens hatched from irradiated eggs. The fact that the concentration of both minerals in blood plasma of chickens hatched from irradiated eggs was significantly changed on the first day proves that the irradiation of eggs by low dose of ionizing radiation on the nineteenth day of incubation had an effect on metabolism of both minerals in those chickens. (author)

  10. Blood flow and blood volume in the femoral heads of healthy adults according to age. Measurement with positron emission tomography (PET)

    International Nuclear Information System (INIS)

    Kubo, Toshikazu; Kimori, Kokuto; Nakamura, Fuminori; Inoue, Shigehiro; Fujioka, Mikihiro; Ueshima, Keiichiro; Hirasawa, Yasusuke; Ushijima, Yo; Nishimura, Tsunehiko

    2001-01-01

    To deepen understanding of hemodynamics in the femoral head, i.e., the essential factor in clarifying pathogenesis of hip disorders, this study examined blood flow and blood volume in the femoral heads of healthy adults, and their changes with age, by using positron emission tomography (PET). In 16 healthy adult males (age: 20-78 years old, mean age: 42 years), blood flow was measured by means of the H 2 15 O dynamic study method, and blood volume was measured by means of the 15 O-labeled carbon monoxide bolus inhalation method. Blood flow was 1.68-6.47 ml/min/100 g (mean ±SD: 3.52±1.2), and blood volume was 1.67-6.03 ml/100 g (mean ±SD: 3.00±1.27). Blood flow significantly decreased (p<0.01) with age, and blood volume significantly increased (P<0.05). PET was useful in the measurement of blood flow and blood volume in the femoral heads. With age, physiological hemodynamic changes also increased in femoral heads. (author)

  11. The toxicological significance of post-mortem drug concentrations in bile.

    Science.gov (United States)

    Ferner, Robin E; Aronson, Jeffrey K

    2018-01-01

    Some authors have proposed that post-mortem drug concentrations in bile are useful in estimating concentrations in blood. Both The International Association of Forensic Toxicologists (TIAFT) and the US Federal Aviation Administration recommend that samples of bile should be obtained in some circumstances. Furthermore, standard toxicological texts compare blood and bile concentrations, implying that concentrations in bile are of forensic value. To review the evidence on simultaneous measurements of blood and bile drug concentrations reported in the medical literature. We made a systematic search of EMBASE 1980-2016 using the search terms ("bile/" OR "exp drug bile level/concentration/") AND "drug blood level/concentration/", PubMed 1975-2017 for ("bile[tw]" OR "biliary[tw]") AND ("concentration[tw]" OR "concentrations[tw]" OR "level[tw]" OR "levels[tw]") AND "post-mortem[tw]" and also MEDLINE 1990-2016 for information on drugs whose biliary concentrations were mentioned in standard textbooks. The search was limited to human studies without language restrictions. We also examined recent reviews, indexes of relevant journals and citations in Web of Science and Google Scholar. We calculated the bile:blood concentration ratio. The searches together yielded 1031 titles with abstracts. We scanned titles and abstracts for relevance and retrieved 230, of which 161 were considered further. We excluded 49 papers because: the paper reported only one case (30 references); the data referred only to a metabolite (1); the work was published before 1980 (3); the information concerned only samples taken during life (10); or the paper referred to a toxin or unusual recreational drug (5). The remaining 112 papers provided data for analysis, with at least two observations for each of 58 drugs. Bile:blood concentration ratios: Median bile:blood concentration ratios varied from 0.18 (range 0.058-0.32) for dextromoramide to 520 (range 0.62-43,000) for buprenorphine. Median bile

  12. Relevance of EDTA carryover during blood collection.

    Science.gov (United States)

    Cadamuro, Janne; Felder, Thomas Klaus; Oberkofler, Hannes; Mrazek, Cornelia; Wiedemann, Helmut; Haschke-Becher, Elisabeth

    2015-07-01

    The order of draw is regarded as a preanalytical issue to prevent carryover of additives during blood collection. Our objective was to prove the theory of ethylenediaminetetraacetic acid (EDTA) carryover for a closed vacuum system and the influence of EDTA on concentrations of selected biomarkers. To test the carryover of EDTA, a blood collection with tripotassium EDTA (K3EDTA) and subsequent non-additive tubes was simulated using distilled water as substitute for blood. EDTA concentrations were measured by tandem mass spectrometry. Then we added increasing concentrations of EDTA to heparinized blood and measured routine biomarkers, thereby simulating a carryover of EDTA whole blood and pure EDTA, respectively. Additionally, we tested for EDTA contamination and biomarker alteration in samples collected from 10 healthy volunteers by a syringe with subsequent transfer into sample tubes. No EDTA contamination was detected in samples collected subsequent to a K3EDTA tube when adhering to guidelines of blood sampling. Magnesium, calcium, and potassium levels were altered by artificial K3EDTA whole-blood contamination as well as when adding 1 μL pure K3EDTA. Iron values were altered at EDTA concentrations of 4.4 mmol/L. All other parameters remained unaffected. A slight EDTA carryover was observed in syringe collection and subsequent transfer into EDTA and heparin tubes, however, without any biomarker alteration. An EDTA carryover during blood collection using a closed vacuum system is highly unlikely. Even if carryover of EDTA whole blood occurs, an absolute volume larger than 10 μL would be necessary to alter test results. However, contamination of samples with preloaded pure K3EDTA solution by severe neglect of current recommendations in blood collection may significantly alter testing results.

  13. Student measurement of blood pressure using a simulator arm compared with a live subject's arm.

    Science.gov (United States)

    Lee, Jennifer J; Sobieraj, Diana M; Kuti, Effie L

    2010-06-15

    To compare accuracy of blood pressure measurements using a live subject and a simulator arm, and to determine students' preferences regarding measurement. This was a crossover study comparing blood pressure measurements from a live subject and a simulator arm. Students completed an anonymous survey instrument defining opinions on ease of measurement. Fifty-seven students completed blood pressure measurements on live subjects while 72 students completed blood pressure measurements using the simulator arm. There were no significant systematic differences between the 2 measurement techniques. Systolic blood pressure measurements from a live subject arm were less likely to be within 4 mm Hg compared with measurements of a simulator arm. Diastolic blood pressure measurements were not significantly different between the 2 techniques. Accuracy of student measurement of blood pressure using a simulator arm was similar to the accuracy with a live subject. There was no difference in students' preferences regarding measurement techniques.

  14. Measurement of Uranium in Blood-Plasma of Bavarian Females

    International Nuclear Information System (INIS)

    Chaudhri, M.A.; Watling, R.J.

    2011-01-01

    It has recently been reported that the water supply in some parts of Bavaria (Germany) contains Uranium. In order to study its effects we have determined the concentrations of U in the blood plasma of 25 females. All the females came from Bavaria and were not on any medication. Blood samples were drawn from a superficial arm vein, centrifuged and plasma extracted. The plasma samples were freeze-dried and analysed in our Analytical Laboratory in Perth, Western Australia by using the technique of ICP-MS. The U contents found varied from less than 0.1 to 8.2 ppb (6.6 ng/L to 543 ng/L)

  15. Nondestructive measurement for radionuclide concentration distribution in soil column

    International Nuclear Information System (INIS)

    Ogawa, Hiromichi; Ohnuki, Toshihiko; Yamamoto, Tadatoshi; Wadachi, Yoshiki

    1985-01-01

    A nondestructive method has been studied for determining the concentration of radionuclide (Cs-137) distributed in a soil column. The concentration distribution was calculated from the counting rate distribution using the efficiency matrix of a detector. The concentration distribution obtained by this method, with measuring efficiencies of theoretical calculation, coincides well with that obtained by the destructive sampling method. This method is, therefore, found to be effective for the measurement of one dimensional concentration distribution. The measuring limit of this method is affected not only by the radionuclide concentration but also by the shape of concentration distribution in a soil column and also by the way it is divided into concentration blocks. It is found that, the radioactive concentration up to 2.6 x 10 -4 μCi/g (9.62 Bq/g), and also the distribution up to where the concentration reduces to half at every 1 cm of depth, can be measured by this system. The concentration blocks can be divided into 1 cm of thickness as a minimum value. (author)

  16. Relationships between recall of perceived exertion and blood lactate concentration in a judo competition.

    Science.gov (United States)

    Serrano, M A; Salvador, A; González-Bono, E G; Sanchís, C; Suay, F

    2001-06-01

    Relationships between perceived exertion and blood lactate have usually been studied in laboratory or training contexts but not in competition, the most important setting in which sports performance is evaluated. The purpose of this study was to examine the relationships between psychological and physiological indices of the physical effort in a competition setting, taking into account the duration of effort. For this, we employed two Ratings of Perceived Exertion (RPE and CR-10) and lactic acid plasma concentration as a biological marker of the effort performed. 13 male judo fighters who participated in a sports club competition provided capillary blood samples to assay lactate concentrations and indicated on scale their Recall of Perceived Exertion in the total competition and again in just the Last Fight to compare the usefulness of RPE and CR-10 in assessing discrete bouts of effort and a whole session. Analysis showed that perceived exertion or the effort made during the whole competition was positively and significantly related to maximal lactate concentration and lactate increase in competition, thus extending the validity of this scale to sports contests. The Recall of Perceived Exertion scores were not significantly correlated with the duration of effort.

  17. Determination of NIR informative wavebands for transmission non-invasive blood glucose measurement using a Fourier transform spectrometer

    Science.gov (United States)

    Yang, Wenming; Liao, Ningfang; Cheng, Haobo; Li, Yasheng; Bai, Xueqiong; Deng, Chengyang

    2018-03-01

    Non-invasive blood glucose measurement using near infrared (NIR) spectroscopy relies on wavebands that provide reliable information about spectral absorption. In this study, we investigated wavebands which are informative for blood glucose in the NIR shortwave band (900˜1450 nm) and the first overtone band (1450˜1700 nm) through a specially designed NIR Fourier transform spectrometer (FTS), which featured a test fixture (where a sample or subject's finger could be placed) and all-reflective optics, except for a Michelson structure. Different concentrations of glucose solution and seven volunteers who had undergone oral glucose tolerance tests (OGTT) were studied to acquire transmission spectra in the shortwave band and the first overtone band. Characteristic peaks of glucose absorption were identified from the spectra of glucose aqueous solution by second-order derivative processing. The wavebands linked to blood glucose were successfully estimated through spectra of the middle fingertip of OGTT participants by a simple linear regression and correlation coefficient. The light intensity difference showed that glucose absorption in the first overtone band was much more prominent than it was in the shortwave band. The results of the SLR model established from seven OGTTs in total on seven participants enabled a positive estimation of the glucose-linked wavelength. It is suggested that wavebands with prominent characteristic peaks, a high correlation coefficient between blood glucose and light intensity difference and a relatively low standard deviation of predicted values will be the most informative wavebands for transmission non-invasive blood glucose measurement methods. This work provides a guidance for waveband selection for the development of non-invasive NIR blood glucose measurement.

  18. PIXE analysis of chinese chicken-blood stone

    International Nuclear Information System (INIS)

    Lin, E.K.; Wang, C.W.; Yu, Y.C.; Liu, T.Y.; Cheng, H.S.; Zhu, H.X.; Yang, H.J.

    1999-01-01

    This paper reports the chemical compositions of chicken-blood stone Ji Xue Shi measured by Proton Induced X-ray Emission (PIXE). The experimental result show that for the red portion of chicken-blood stone, the concentration of Hg is as high as 20 wt%, and the concentration of S can be above 10 wt%. For the non-red portion the main chemical compositions are Al 2 O 3 and SiO 2 . The obtained chemical compositions are close to those of kaolinite for Balin chicken-blood stone, and of pyrophyllite for Changhua chicken-blood stone, respectively. So far many Changhua chicken-blood stones and Balin chicken-blood stones were found in China, the PIXE method can be used to explore the provenance of available chicken-blood stones. (author)

  19. Blood pressure measurement of all five fingers by strain gauge plethysmography

    DEFF Research Database (Denmark)

    Hirai, M; Nielsen, S L; Lassen, N A

    1976-01-01

    of the other fingers was measured using a 24-mm-wide cuff. Blood pressure at the proximal phalanx was higher than that at the intermediate phalanx in all fingers except finger V. The difference of blood pressure values corresponded well with circumference of the finger. In 15 normal subjects, blood pressure...... at the proximal phalanx was compared in fingers I, III, IV, and V, using 16, 20, 24 and 24 mm wide cuffs. Finger blood pressure was closest to arm systolic blood pressure when a 24-mm or 27-mm-wide cuff was used in fingers I, III, and IV, and with a 20-mm-wide cuff in finger V. As the standard deviation......The aim of the present paper was to study the methodological problems involved in measuring systolic blood pressure in all five fingers by the strain gauge technique. In 24 normal subjects, blood pressure at the proximal phalanx of finger I and both at the proximal and the intermediate phalanx...

  20. Elevated blood harmane (1-methyl-9H-pyrido[3,4-b]indole) concentrations in Parkinson's disease.

    Science.gov (United States)

    Louis, Elan D; Michalec, Monika; Jiang, Wendy; Factor-Litvak, Pam; Zheng, Wei

    2014-01-01

    Parkinson's disease (PD) is a late-life neurodegenerative disease. Genetic and environmental factors play an etiological role. Harmane (1-methyl-9H-pyrido[3,4-b]indole) is a potent tremor-producing neurotoxin that shows structural resemblance to 1-methyl-4-phenyl-1,2,3,6-tetrahydropyridine (MPTP). In 2002 and 2007, we demonstrated elevated blood harmane concentrations [HA] in essential tremor (ET) cases. We now assessed whether blood [HA] were elevated in Parkinson's disease (PD) as well. Blood [HA] were quantified by high performance liquid chromatography. Subjects comprised 113 PD cases and 101 controls. Mean log blood [HA] in PD cases was double that of controls (0.59±0.63 g(-10)/ml vs. 0.27±0.63 g(-10)/ml, p<0.001). A non-parametric test on non-transformed data (median blood [HA]=3.31 g(-10)/ml in cases and 1.44 g(-10)/ml in controls) also showed this difference (p<0.001). In unadjusted and then adjusted logistic regression analyses, log blood [HA] was associated with PD (odds ratio [OR]unadjusted 2.31, 95% confidence interval [CI] 1.46-3.67, p<0.001; OR(adjusted) 2.54, 95% CI 1.55-4.16, p<0.001). In PD, log blood [HA] co-varied with family history, being lowest in PD cases with no family history (0.54±0.60 g(-10)/ml) and highest in PD cases with a family history of both ET and PD (0.84±0.68 g(-10)/ml) (p=0.06). Blood harmane appears to be elevated in PD. The finding needs to be reproduced in additional cohorts to assess its generalizability. The higher concentration in familial PD suggests that the mechanism may involve genetic factors. Copyright © 2013 Elsevier Inc. All rights reserved.

  1. Effects of Contrast Media on Blood Rheology: Comparison in Humans, Pigs, and Sheep

    International Nuclear Information System (INIS)

    Laurent, Alexandre; Durussel, Jean Jacques; Dufaux, Jacques; Penhouet, Laurence; Bailly, Anne Laure; Bonneau, Michel; Merland, Jean Jacques

    1999-01-01

    Purpose: To compare whole blood viscosity and erythrocyte aggregation in humans, pigs, and sheep, before and after adding water-soluble iodinated contrast medium (CM). Methods: Two CMs were studied: iopromide (nonionic) and ioxaglate (ionic). The blood-CM viscosity was measured with a Couette viscometer. Erythrocyte aggregation was measured with an erythroaggregometer. Results: The blood-CM viscosity was increased up to +20% (relative to pure blood) with a CM concentration of 0%-10%. At CM concentrations from 10% to 50%, the viscosity decreased. The disaggregation shear stress was increased (relative to pure blood) at low CM concentration (0%-10%). When the CM concentration increased from 10% to 20%, the disaggregation shear stress was decreased, except with the pig blood-ioxaglate mixture. Conclusion: At low CM concentration the blood viscosity was increased in pig, sheep, and humans and the disaggregation shear stress was increased in pig and humans. The aggregation of sheep blood was too low to be detected by the erythroaggregometer. This rise can be explained by the formation of poorly deformable echinocytes. At higher CM concentration, the viscosity and the disaggregation shear stress decreased in relation to the blood dilution. We conclude that pig blood and sheep blood can both be used to study the effect of CM injection on blood viscosity. Nevertheless, the rheologic behavior of pig blood in terms of erythrocyte aggregation is closer to that of human blood than is sheep blood when mixed with CM. Pigs could thus be more suitable than sheep for in vivo studies of CM miscibility with blood during selective cannulation procedures

  2. The Chronic and Acute Effects of Exercise Upon Selected Blood Measures.

    Science.gov (United States)

    Roitman, J. L.; Brewer, J. P.

    This study investigated the effects of chronic and acute exercise upon selected blood measures and indices. Nine male cross-country runners were studied. Red blood count, hemoglobin, and hematocrit were measured using standard laboratory techniques; mean corpuscular volume (MCV), mean corpuscular hemoglobin, and mean corpuscular hemoglobin…

  3. Blood doping by cobalt. Should we measure cobalt in athletes?

    Directory of Open Access Journals (Sweden)

    Guidi Gian

    2006-07-01

    Full Text Available Abstract Background Blood doping is commonplace in competitive athletes who seek to enhance their aerobic performances through illicit techniques. Presentation of the hypothesis Cobalt, a naturally-occurring element with properties similar to those of iron and nickel, induces a marked and stable polycythemic response through a more efficient transcription of the erythropoietin gene. Testing the hypothesis Although little information is available so far on cobalt metabolism, reference value ranges or supplementation in athletes, there is emerging evidence that cobalt is used as a supplement and increased serum concentrations are occasionally observed in athletes. Therefore, given the athlete's connatural inclination to experiment with innovative, unfair and potentially unhealthy doping techniques, cobalt administration might soon become the most suited complement or surrogate for erythropoiesis-stimulating substances. Nevertheless, cobalt administration is not free from unsafe consequences, which involve toxic effects on heart, liver, kidney, thyroid and cancer promotion. Implications of the hypothesis Cobalt is easily purchasable, inexpensive and not currently comprehended within the World Anti-Doping Agency prohibited list. Moreover, available techniques for measuring whole blood, serum, plasma or urinary cobalt involve analytic approaches which are currently not practical for antidoping laboratories. Thus more research on cobalt metabolism in athletes is compelling, along with implementation of effective strategies to unmask this potentially deleterious doping practice

  4. Red blood cell-deformability measurement: review of techniques.

    Science.gov (United States)

    Musielak, M

    2009-01-01

    Cell-deformability characterization involves general measurement of highly complex relationships between cell biology and physical forces to which the cell is subjected. The review takes account of the modern technical solutions simulating the action of the force applied to the red blood cell in macro- and microcirculation. Diffraction ektacytometers and rheoscopes measure the mean deformability value for the total red blood cell population investigated and the deformation distribution index of individual cells, respectively. Deformation assays of a whole single cell are possible by means of optical tweezers. The single cell-measuring setups for micropipette aspiration and atomic force microscopy allow conducting a selective investigation of deformation parameters (e.g., cytoplasm viscosity, viscoelastic membrane properties). The distinction between instrument sensitivity to various RBC-rheological features as well as the influence of temperature on measurement are discussed. The reports quoted confront fascinating possibilities of the techniques with their medical applications since the RBC-deformability has the key position in the etiology of a wide range of conditions.

  5. Enhanced nutrition improves growth and increases blood adiponectin concentrations in very low birth weight infants

    Directory of Open Access Journals (Sweden)

    Elin W. Blakstad

    2016-12-01

    Full Text Available Background: Adequate nutrient supply is essential for optimal postnatal growth in very low birth weight (VLBW, birth weight<1,500 g infants. Early growth may influence the risk of metabolic syndrome later in life. Objective: To evaluate growth and blood metabolic markers (adiponectin, leptin, and insulin-like growth factor-1 (IGF-1 in VLBW infants participating in a randomized nutritional intervention study. Design: Fifty VLBW infants were randomized to an enhanced nutrient supply or a standard nutrient supply. Thirty-seven infants were evaluated with growth measurements until 2 years corrected age (CA. Metabolic markers were measured at birth and 5 months CA. Results: Weight gain and head growth were different in the two groups from birth to 2 years CA (weight gain: pinteraction=0.006; head growth: pinteraction=0.002. The intervention group improved their growth z-scores after birth, whereas the control group had a pronounced decline, followed by an increase and caught up with the intervention group after discharge. At 5 months CA, adiponectin concentrations were higher in the intervention group and correlated with weight gain before term (r=0.35 and nutrient supply (0.35≤r≤0.45. Leptin concentrations correlated with weight gain after term and IGF-1 concentrations with length growth before and after term and head growth after term (0.36≤r≤0.53. Conclusion: Enhanced nutrient supply improved early postnatal growth and may have prevented rapid catch-up growth later in infancy. Adiponectin concentration at 5 months CA was higher in the intervention group and correlated positively with early weight gain and nutrient supply. Early nutrition and growth may affect metabolic markers in infancy.Clinical Trial Registration (ClinicalTrials.gov no.: NCT01103219

  6. Aortic blood flow subtraction: an alternative method for measuring total renal blood flow in conscious dogs

    DEFF Research Database (Denmark)

    Sandgaard, N C F; Andersen, J L; Holstein-Rathlou, N-H

    2002-01-01

    We have measured total renal blood flow (TRBF) as the difference between signals from ultrasound flow probes implanted around the aorta above and below the renal arteries. The repeatability of the method was investigated by repeated, continuous infusions of angiotensin II and endothelin-1 seven...... arterial blood pressure by 49% and decreased TRBF by 12%, providing an increase in renal vascular resistance of 69%. Dynamic analysis showed autoregulation of renal blood flow in the frequency range ... of TRBF by aortic blood flow subtraction is a practical and reliable method that allows direct comparison of excretory function and renal blood flow from two kidneys. The method also allows direct comparison between TRBF and flow in the caudal aorta....

  7. Benzene in blood as a biomarker of low level occupational exposure

    Energy Technology Data Exchange (ETDEWEB)

    Brugnone, F.; Perbellini, L.; Romeo, L.; Cerpelloni, M.; Bianchin, M.; Tonello, A. [Institute of Occupational Medicine, University of Verona, Policlinico Borgo Roma, 37134 Verona (Italy)

    1999-09-01

    The occupational airborne exposure to benzene of 150 workers employed in petrol stations and a refinery plant was assessed using personal sampling pumps. All workers provided blood samples after the end of work and on the following morning before resuming work. Benzene concentrations in the blood of 243 non-occupationally-exposed subjects were also measured. The median occupational benzene exposure for all 150 workers studied was 80 {mu}g/m{sup 3}. Overall median blood benzene of all workers was 251 ng/l at the end of the shift, and 174 ng/l the following morning. The benzene concentrations measured in blood collected the following morning proved to be significantly lower than those measured at the end of the shift. Median blood benzene for the 243 'normal' subjects was 128 ng/l, which was significantly lower than that measured in the workers before a new work shift. The median blood benzene concentration was significantly higher in smokers than in non-smokers, both in the general population (210 ng/l vs. 110 ng/l) and in the exposed workers at the end of the shift (476 ng/l vs. 132 ng/l) and the following morning (360 ng/l vs. 99 ng/l). End-of-shift blood benzene correlated significantly with environmental exposure; this correlation was better in the 83 non-smokers than in the 67 smokers. In non-smokers with the median benzene occupational exposure of 50 {mu}g/m{sup 3}, no difference was found in blood benzene concentration in exposed and non-exposed subjects.

  8. Association of PNC, BC, and PM2.5 Measured at a Central Monitoring Site with Blood Pressure in a Predominantly Near Highway Population

    Directory of Open Access Journals (Sweden)

    Mei Chung

    2015-03-01

    Full Text Available Elevated blood pressure is an indicator of cardiovascular stress and increased risk of cardiovascular-related morbidity and mortality. There is emerging evidence suggesting air pollutants, including particulate matter (PM, could promote hypertension, thereby increasing cardiovascular disease risk. Repeated measurement analyses were conducted to examine the associations of three types of PM with systolic blood pressure (SBP, diastolic blood pressure (DBP, and pulse pressure (PP in 220 participants, (mean age = 58.5 years from the Community Assessment of Freeway Exposure and Health study (CAFEH, most of whom live near a major highway. Ambient levels of air pollutants including particle number concentration (PNC; a measure of ultrafine particle (UFP concentration, fine PM (PM2.5, Particle diameter <2.5 µm, and black carbon (BC were measured at a central site <7 km from the study areas. Central sites are good at capturing short-term temporal trends in pollution associated with meteorological changes over regional areas. Linear mixed-effect models that accounted for repeated measures within one person were used to examine the associations between blood pressure variables and daily average of ambient PNC, PM2.5, or BC, controlling for demographic characteristics and major confounders including temperature. Our PNC model predicted that a higher PNC of 10,000 particles/cm3 was associated with higher DBP of 2.40 mmHg (p = 0.03, independent of other factors in the model. There were no significant associations for PM2.5 or BC. Post hoc subgroup analyses by obesity status showed that positive associations of DBP with PNC were more pronounced among obese individuals than non-obese individuals. These results suggested that PNC levels are associated with increased blood pressure, which may contribute to cardiovascular disease risk. More research is needed to assess the relationship between PNC and blood pressure and to address possible residual confounding.

  9. Agreement between direct and indirect blood pressure measurements obtained from anesthetized Hispaniolan Amazon parrots.

    Science.gov (United States)

    Acierno, Mark J; da Cunha, Anderson; Smith, Julie; Tully, Thomas N; Guzman, David Sanchez-Migallon; Serra, Verna; Mitchell, Mark A

    2008-11-15

    To determine the level of agreement between direct and indirect blood pressure measurements obtained from healthy Hispaniolan Amazon parrots (Amazona ventralis) anesthetized with isoflurane. Validation study. 16 healthy adult Hispaniolan Amazon parrots. Parrots were anesthetized, and a 26-gauge, 19-mm catheter was placed percutaneously in the superficial ulnar artery for direct measurement of systolic, mean, and diastolic arterial pressures. Indirect blood pressure measurements were obtained with a Doppler ultrasonic flow detector and an oscillometric unit. The Bland-Altman method was used to compare direct and indirect blood pressure values. There was substantial disagreement between direct systolic arterial blood pressure and indirect blood pressure measurements obtained with the Doppler detector from the wing (bias, 24 mm Hg; limits of agreement, -37 to 85 mm Hg) and from the leg (bias, 14 mm Hg; limits of agreement, -14 to 42 mm Hg). Attempts to obtain indirect blood pressure measurements with the oscillometric unit were unsuccessful. Results suggested that there was substantial disagreement between indirect blood pressure measurements obtained with a Doppler ultrasonic flow detector in anesthetized Hispaniolan Amazon parrots and directly measured systolic arterial blood pressure.

  10. Noninvasive blood pressure measurement scheme based on optical fiber sensor

    Science.gov (United States)

    Liu, Xianxuan; Yuan, Xueguang; Zhang, Yangan

    2016-10-01

    Optical fiber sensing has many advantages, such as volume small, light quality, low loss, strong in anti-jamming. Since the invention of the optical fiber sensing technology in 1977, optical fiber sensing technology has been applied in the military, national defense, aerospace, industrial, medical and other fields in recent years, and made a great contribution to parameter measurement in the environment under the limited condition .With the rapid development of computer, network system, the intelligent optical fiber sensing technology, the sensor technology, the combination of computer and communication technology , the detection, diagnosis and analysis can be automatically and efficiently completed. In this work, we proposed a noninvasive blood pressure detection and analysis scheme which uses optical fiber sensor. Optical fiber sensing system mainly includes the light source, optical fiber, optical detector, optical modulator, the signal processing module and so on. wavelength optical signals were led into the optical fiber sensor and the signals reflected by the human body surface were detected. By comparing actual testing data with the data got by traditional way to measure the blood pressure we can establish models for predicting the blood pressure and achieve noninvasive blood pressure measurement by using spectrum analysis technology. Blood pressure measurement method based on optical fiber sensing system is faster and more convenient than traditional way, and it can get accurate analysis results in a shorter period of time than before, so it can efficiently reduce the time cost and manpower cost.

  11. Nonsmoker Exposure to Secondhand Cannabis Smoke. III. Oral Fluid and Blood Drug Concentrations and Corresponding Subjective Effects.

    Science.gov (United States)

    Cone, Edward J; Bigelow, George E; Herrmann, Evan S; Mitchell, John M; LoDico, Charles; Flegel, Ronald; Vandrey, Ryan

    2015-09-01

    The increasing use of highly potent strains of cannabis prompted this new evaluation of human toxicology and subjective effects following passive exposure to cannabis smoke. The study was designed to produce extreme cannabis smoke exposure conditions tolerable to drug-free nonsmokers. Six experienced cannabis users smoked cannabis cigarettes [5.3% Δ(9)-tetrahydrocannabinol (THC) in Session 1 and 11.3% THC in Sessions 2 and 3] in a closed chamber. Six nonsmokers were seated alternately with smokers during exposure sessions of 1 h duration. Sessions 1 and 2 were conducted with no ventilation and ventilation was employed in Session 3. Oral fluid, whole blood and subjective effect measures were obtained before and at multiple time points after each session. Oral fluid was analyzed by ELISA (4 ng/mL cutoff concentration) and by LC-MS-MS (limit of quantitation) for THC (1 ng/mL) and total THCCOOH (0.02 ng/mL). Blood was analyzed by LC-MS-MS (0.5 ng/mL) for THC, 11-OH-THC and free THCCOOH. Positive tests for THC in oral fluid and blood were obtained for nonsmokers up to 3 h following exposure. Ratings of subjective effects correlated with the degree of exposure. Subjective effect measures and amounts of THC absorbed by nonsmokers (relative to smokers) indicated that extreme secondhand cannabis smoke exposure mimicked, though to a lesser extent, active cannabis smoking. © The Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  12. Development of an aptamer-based concentration method for the detection of Trypanosoma cruzi in blood.

    Directory of Open Access Journals (Sweden)

    Rana Nagarkatti

    Full Text Available Trypanosoma cruzi, a blood-borne parasite, is the etiological agent of Chagas disease. T. cruzi trypomastigotes, the infectious life cycle stage, can be detected in blood of infected individuals using PCR-based methods. However, soon after a natural infection, or during the chronic phase of Chagas disease, the number of parasites in blood may be very low and thus difficult to detect by PCR. To facilitate PCR-based detection methods, a parasite concentration approach was explored. A whole cell SELEX strategy was utilized to develop serum stable RNA aptamers that bind to live T. cruzi trypomastigotes. These aptamers bound to the parasite with high affinities (8-25 nM range. The highest affinity aptamer, Apt68, also demonstrated high specificity as it did not interact with the insect stage epimastigotes of T. cruzi nor with other related trypanosomatid parasites, L. donovani and T. brucei, suggesting that the target of Apt68 was expressed only on T. cruzi trypomastigotes. Biotinylated Apt68, immobilized on a solid phase, was able to capture live parasites. These captured parasites were visible microscopically, as large motile aggregates, formed when the aptamer coated paramagnetic beads bound to the surface of the trypomastigotes. Additionally, Apt68 was also able to capture and aggregate trypomastigotes from several isolates of the two major genotypes of the parasite. Using a magnet, these parasite-bead aggregates could be purified from parasite-spiked whole blood samples, even at concentrations as low as 5 parasites in 15 ml of whole blood, as detected by a real-time PCR assay. Our results show that aptamers can be used as pathogen specific ligands to capture and facilitate PCR-based detection of T. cruzi in blood.

  13. Cutaneous and subcutaneous blood flow measurements in psoriasis

    International Nuclear Information System (INIS)

    Klemp, P.

    1987-01-01

    The experiments - published in 7 papers in The Journal of Investigative Dermatology 1983-86 - have demonstrated: 1. The accuracy of the local 133 Xe washout method is about 15% for estimation of the cutaneous blood flow (CBF), and about 10% for subcutaneous blood flow measurements (SBF). In measurements of absolute CBF values a graphic curve resolution of the washout curve should alwaus be performed. Otherwise the CBF might be considerably underestimated. 2. CdTe(Cl) mini-detectors can be attached directly to the skin, and might yield measurements of both CBF and SBF that can substitute for those made with conventional detectors. 3. The laser Doppler measurements could not be correlated to quantitative measurements of the CBF. 4. The tissue-to-blood partition coefficient for 133 Xe of lesional psoriatic skin (LS) is increased. 5. In untreated, LS of patients with active psoriasis the CBF is about a factor of 10 times higher than the CBF of normal individuals. In non-lesional skin (NLS) of patients with active psoriasis the CBF is about a factor of 2 higher than the CBF of normal individuals. However, the CBF did not differ in NLS of patients with minimal skin manifestations. The high CBF decreases gradualy during antipsoriatic treatment. 6. A paradoxical autoregulation of the CBF was observed in LS. 7. The high CBF is not due to a maximally dilated vascular bed. 8. The SBF in LS areas was a factor of higher than the SBF in normal individuals. 9. A normal, local regulation of the SBF was found. (author)

  14. Coagulation measurement from whole blood using vibrating optical fiber in a disposable cartridge.

    Science.gov (United States)

    Yaraş, Yusuf Samet; Gündüz, Ali Bars; Sağlam, Gökhan; Ölçer, Selim; Civitçi, Fehmi; Baris, İbrahim; Yaralioğlu, Göksenin; Urey, Hakan

    2017-11-01

    In clinics, blood coagulation time measurements are performed using mechanical measurements with blood plasma. Such measurements are challenging to do in a lab-on-a-chip (LoC) system using a small volume of whole blood. Existing LoC systems use indirect measurement principles employing optical or electrochemical methods. We developed an LoC system using mechanical measurements with a small volume of whole blood without requiring sample preparation. The measurement is performed in a microfluidic channel where two fibers are placed inline with a small gap in between. The first fiber operates near its mechanical resonance using remote magnetic actuation and immersed in the sample. The second fiber is a pick-up fiber acting as an optical sensor. The microfluidic channel is engineered innovatively such that the blood does not block the gap between the vibrating fiber and the pick-up fiber, resulting in high signal-to-noise ratio optical output. The control plasma test results matched well with the plasma manufacturer's datasheet. Activated-partial-thromboplastin-time tests were successfully performed also with human whole blood samples, and the method is proven to be effective. Simplicity of the cartridge design and cost of readily available materials enable a low-cost point-of-care device for blood coagulation measurements. (2017) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE).

  15. Relationship between the change of ethological status and concentration of certain cytokines in blood in experimental desynchronosis under led lighting.

    Science.gov (United States)

    Osikov, M V; Ogneva, O I

    2016-01-01

    Changing the natural rhythm of day and night leads to the development of DS, disruption of coordinated muscular activity, adequate behavioral activity, a decrease of attention in the performance of night work by experts in various fields. Changes ethological status may potentiate or weaken the changes in the indices of immune status, contribute to the formation of allostatic load at desynchronosis. To investigate the relationship between changes ethological status and concentration of certain cytokines in peripheral blood in experimental desynchronosis under LED lighting. The study was performed on 158 adult guinea pigs, which were randomly assigned into 2 groups: 1 group- animals in the conditions of standard fixed (12 h light / 12 h dark) LED lighting (SFSDO); 2 group- animals with jet lag in terms of LED lighting (DESSDO). Light desynchronosis created by keeping animals at clock coverage for 30 days. Behavioral activity was studied in the test «open field» cognitive function was assessed using aqueous «labyrinth» Morris. By ELISA was determined on the apparatus in the peripheral blood concentration of interleukin - 4 (IL-4), interferon-gamma (IFN-g), melatonin, cortisol via specific for guinea pig test systems. It was found that in animals of DS in terms of LED lighting in the dynamics of 10-30 days of observation show signs of anxiety, depression orienting-exploratory behavior, reduce the long-term memory and learning ability, spatial orientation disorders. It found that when a jet lag LED lighting conditions for 10 days, 20 days and 30 days in peripheral blood melatonin concentration decreases, the concentration of cortisol rises. In peripheral blood decreased IL-4 concentrations of 20 and 30 days, reducing the concentration of IFN-g at 30 days. Based on the results of correlation analysis, ethological change status and progress of cognitive function with a decrease in the blood concentration of IL-4 and IFN-g, the concentration of melatonin increase

  16. Using the area under the curve to reduce measurement error in predicting young adult blood pressure from childhood measures.

    Science.gov (United States)

    Cook, Nancy R; Rosner, Bernard A; Chen, Wei; Srinivasan, Sathanur R; Berenson, Gerald S

    2004-11-30

    Tracking correlations of blood pressure, particularly childhood measures, may be attenuated by within-person variability. Combining multiple measurements can reduce this error substantially. The area under the curve (AUC) computed from longitudinal growth curve models can be used to improve the prediction of young adult blood pressure from childhood measures. Quadratic random-effects models over unequally spaced repeated measures were used to compute the area under the curve separately within the age periods 5-14 and 20-34 years in the Bogalusa Heart Study. This method adjusts for the uneven age distribution and captures the underlying or average blood pressure, leading to improved estimates of correlation and risk prediction. Tracking correlations were computed by race and gender, and were approximately 0.6 for systolic, 0.5-0.6 for K4 diastolic, and 0.4-0.6 for K5 diastolic blood pressure. The AUC can also be used to regress young adult blood pressure on childhood blood pressure and childhood and young adult body mass index (BMI). In these data, while childhood blood pressure and young adult BMI were generally directly predictive of young adult blood pressure, childhood BMI was negatively correlated with young adult blood pressure when childhood blood pressure was in the model. In addition, racial differences in young adult blood pressure were reduced, but not eliminated, after controlling for childhood blood pressure, childhood BMI, and young adult BMI, suggesting that other genetic or lifestyle factors contribute to this difference. 2004 John Wiley & Sons, Ltd.

  17. Hydrogen clearance: Assessment of technique for measurement of skin-flap blood flow in pigs

    International Nuclear Information System (INIS)

    Thomson, J.G.; Kerrigan, C.L.

    1991-01-01

    The hydrogen clearance technique has been used for many years by investigators to determine brain blood flow and has been partially validated in this setting using other methods of blood flow measurement. The method has been modified to allow blood flow measurements in skin, but the accuracy of H2 clearance for measuring skin blood flow has not been determined. Multiple blood flow measurements were performed using H2 clearance and radioactive microspheres on skin flaps and control skin in pigs. On 12 pigs, a total of 117 flap and 42 control skin measurements were available for analysis. There was no significant difference between the two techniques in measuring mean control skin blood flow. In skin flaps, H2 clearance was significantly correlated to microsphere-measured blood flow, but it consistently gave an overestimate. Sources of error may include injury to the tissues by insertion of electrodes, consumption of H2 by the electrodes, or diffusion of H2 from the relatively ischemic flap to its well-vascularized bed. Further studies are necessary to determine the cause of this error and to measure the technique's accuracy in skeletal muscle and other flaps

  18. [Ischemic Changes in the Electrocardiogram and Circulatory Collapse Accompanied by Severe Anemia Owing to the Delay of Red Blood Cell Concentrate Transfusion in Two Patients with Intraoperative Massive Bleeding].

    Science.gov (United States)

    Horiuchi, Toshinori; Noguchi, Teruo; Kurita, Naoko; Yamaguchi, Ayako; Takeda, Masafumi; Sha, Keiichi; Nagahata, Toshihiro

    2016-01-01

    We present two patients developing intraoperative massive bleeding and showed ischemic changes in the electrocardiogram and circulatory collapse accompanied by severe anemia owing to the delay of red blood cell concentrate transfusion. One patient underwent hepatectomy and the other pancreaticoduodenectomy. Their lowest hemoglobin concentration was around 2 g x dl(-1), and they showed ischemic changes in the electrocardiogram and severe decreases in blood pressure. The former received compatible red blood cell concentrate and the latter received uncrossmatched same blood group red blood cell concentrate immediately, and their electrocardiogram and blood pressure quickly improved. To avoid life-threatening anemia, emergency red blood cell concentrate transfusion including compatible different blood group transfusion should be applied for intraoperative massive bleeding.

  19. Reliable blood pressure self-measurement in the obstetric waiting room

    DEFF Research Database (Denmark)

    Wagner, Stefan; Kamper, C. H.; Rasmussen, Niels H

    2014-01-01

    Background: Patients often fail to adhere to clinical recommendations when using current blood pressure self-measurement (BPSM) methods and equipment. As existing BPSM equipment is not able to detect non-adherent behavior, this could result in misdiagnosis and treatment error. To overcome...... patients scheduled for self-measuring their blood pressure (BP) in the waiting room at an obstetrics department's outpatient clinic to perform an additional BPSM using ValidAid. We then compared the automatically measured and classified values from ValidAid with our manual observations. Results: We found...

  20. Assessing the Association between Natural Food Folate Intake and Blood Folate Concentrations: A Systematic Review and Bayesian Meta-Analysis of Trials and Observational Studies

    Directory of Open Access Journals (Sweden)

    Claire M. Marchetta

    2015-04-01

    Full Text Available Folate is found naturally in foods or as synthetic folic acid in dietary supplements and fortified foods. Adequate periconceptional folic acid intake can prevent neural tube defects. Folate intake impacts blood folate concentration; however, the dose-response between natural food folate and blood folate concentrations has not been well described. We estimated this association among healthy females. A systematic literature review identified studies (1 1992–3 2014 with both natural food folate intake alone and blood folate concentration among females aged 12–49 years. Bayesian methods were used to estimate regression model parameters describing the association between natural food folate intake and subsequent blood folate concentration. Seven controlled trials and 29 observational studies met the inclusion criteria. For the six studies using microbiologic assay (MA included in the meta-analysis, we estimate that a 6% (95% Credible Interval (CrI: 4%, 9% increase in red blood cell (RBC folate concentration and a 7% (95% CrI: 1%, 12% increase in serum/plasma folate concentration can occur for every 10% increase in natural food folate intake. Using modeled results, we estimate that a natural food folate intake of ≥450 μg dietary folate equivalents (DFE/day could achieve the lower bound of an RBC folate concentration (~1050 nmol/L associated with the lowest risk of a neural tube defect. Natural food folate intake affects blood folate concentration and adequate intakes could help women achieve a RBC folate concentration associated with a risk of 6 neural tube defects/10,000 live births.

  1. Assessing the association between natural food folate intake and blood folate concentrations: a systematic review and Bayesian meta-analysis of trials and observational studies.

    Science.gov (United States)

    Marchetta, Claire M; Devine, Owen J; Crider, Krista S; Tsang, Becky L; Cordero, Amy M; Qi, Yan Ping; Guo, Jing; Berry, Robert J; Rosenthal, Jorge; Mulinare, Joseph; Mersereau, Patricia; Hamner, Heather C

    2015-04-10

    Folate is found naturally in foods or as synthetic folic acid in dietary supplements and fortified foods. Adequate periconceptional folic acid intake can prevent neural tube defects. Folate intake impacts blood folate concentration; however, the dose-response between natural food folate and blood folate concentrations has not been well described. We estimated this association among healthy females. A systematic literature review identified studies (1 1992-3 2014) with both natural food folate intake alone and blood folate concentration among females aged 12-49 years. Bayesian methods were used to estimate regression model parameters describing the association between natural food folate intake and subsequent blood folate concentration. Seven controlled trials and 29 observational studies met the inclusion criteria. For the six studies using microbiologic assay (MA) included in the meta-analysis, we estimate that a 6% (95% Credible Interval (CrI): 4%, 9%) increase in red blood cell (RBC) folate concentration and a 7% (95% CrI: 1%, 12%) increase in serum/plasma folate concentration can occur for every 10% increase in natural food folate intake. Using modeled results, we estimate that a natural food folate intake of ≥ 450 μg dietary folate equivalents (DFE)/day could achieve the lower bound of an RBC folate concentration (~ 1050 nmol/L) associated with the lowest risk of a neural tube defect. Natural food folate intake affects blood folate concentration and adequate intakes could help women achieve a RBC folate concentration associated with a risk of 6 neural tube defects/10,000 live births.

  2. Effect measure modification of blood lead-air lead slope factors.

    Science.gov (United States)

    Richmond-Bryant, Jennifer; Meng, Qingyu; Cohen, Jonathan; Davis, J Allen; Svendsgaard, David; Brown, James S; Tuttle, Lauren; Hubbard, Heidi; Rice, Joann; Kirrane, Ellen; Vinikoor-Imler, Lisa; Kotchmar, Dennis; Hines, Erin; Ross, Mary

    2015-01-01

    There is abundant literature finding that susceptibility factors, including race and ethnicity, age, and housing, directly influence blood lead levels. No study has explored how susceptibility factors influence the blood lead-air lead relationship nationally. The objective is to evaluate whether susceptibility factors act as effect measure modifiers on the blood lead-air lead relationship. Participant level blood lead data from the 1999 to 2008 National Health and Nutrition Examination Survey were merged with air lead data from the US Environmental Protection Agency. Linear mixed effects models were run with and without an air lead interaction term for age group, sex, housing age, or race/ethnicity to determine whether these factors are effect measure modifiers for all ages combined and for five age brackets. Age group and race/ethnicity were determined to be effect measure modifiers in the all-age model and for some age groups. Being a child (1-5, 6-11, and 12-19 years) or of Mexican-American ethnicity increased the effect estimate. Living in older housing (built before 1950) decreased the effect estimate for all models except for the 1-5-year group, where older housing was an effect measure modifier. These results are consistent with the peer-reviewed literature of time-activity patterns, ventilation, and toxicokinetics.

  3. Workplace aerosol mass concentration measurement using optical particle counters.

    Science.gov (United States)

    Görner, Peter; Simon, Xavier; Bémer, Denis; Lidén, Göran

    2012-02-01

    Direct-reading aerosol measurement usually uses the optical properties of airborne particles to detect and measure particle concentration. In the case of occupational hygiene, mass concentration measurement is often required. Two aerosol monitoring methods are based on the principle of light scattering: optical particle counting (OPC) and photometry. The former analyses the light scattered by a single particle, the latter by a cloud of particles. Both methods need calibration to transform the quantity of scattered light detected into particle concentration. Photometers are simpler to use and can be directly calibrated to measure mass concentration. However, their response varies not only with aerosol concentration but also with particle size distribution, which frequently contributes to biased measurement. Optical particle counters directly measure the particle number concentration and particle size that allows assessment of the particle mass provided the particles are spherical and of known density. An integrating algorithm is used to calculate the mass concentration of any conventional health-related aerosol fraction. The concentrations calculated thus have been compared with simultaneous measurements by conventional gravimetric sampling to check the possibility of field OPC calibration with real workplace aerosols with a view to further monitoring particle mass concentration. Aerosol concentrations were measured in the food industry using the OPC GRIMM® 1.108 and the CIP 10-Inhalable and CIP 10-Respirable (ARELCO®) aerosol samplers while meat sausages were being brushed and coated with calcium carbonate. Previously, the original OPC inlet had been adapted to sample inhalable aerosol. A mixed aerosol of calcium carbonate and fungi spores was present in the workplace. The OPC particle-size distribution and an estimated average particle density of both aerosol components were used to calculate the mass concentration. The inhalable and respirable aerosol fractions

  4. Second measurement of morning systolic blood pressure is more closely associated with albuminuria.

    Science.gov (United States)

    Sakabe, Kazumi; Fukui, Michiaki; Ushigome, Emi; Hamaguchi, Masahide; Tanaka, Toru; Atsuta, Haruhiko; Ohnishi, Masayoshi; Oda, Yohei; Hasegawa, Goji; Nakamura, Naoto

    2012-08-01

    It is important to control blood pressure as well as to control blood glucose for the prevention of diabetic nephropathy. However, to our knowledge, there are no reports investigating which blood pressure, including morning, evening and clinic, is more closely associated with albuminuria and whether one measurement is sufficient or not in patients with Type 2 diabetes. We measured morning, evening and clinic blood pressure and compared the area under the curve (AUC) of blood pressure for urinary albumin excretion equal to or more than 30 mg/g creatinine using receiver-operating characteristic curve analyses and odds ratio for albuminuria defined as urinary albumin excretion equal to or more than 30 mg/g creatinine in 858 patients with Type 2 diabetes. Odds ratio (95% confidence interval (CI)) of morning, evening and clinic systolic blood pressure for albuminuria was 1.034 (1.024 - 1.044), 1.033 (1.023 - 1.043) and 1.013 (1.055 - 1.021), respectively (p AUC of morning, evening and clinic systolic blood pressure was 0.644 (0.628 - 0.700) (p AUC of the second morning systolic blood pressure was greater than the first (p = 0.033). The second measurement of morning systolic blood pressure is more closely associated with albuminuria than the first measurement of the morning in addition to clinic systolic blood pressure.

  5. Impact of Biological Feedback and Incentives on Blood Fatty Acid Concentrations, Including Omega-3 Index, in an Employer-Based Wellness Program

    Directory of Open Access Journals (Sweden)

    Michael I. McBurney

    2017-08-01

    Full Text Available Eicosapentaenoic acid (EPA, C20:5n-3 and docosahexaenoic acid (DHA, C22:6n-3 are important fatty acids for the retina and brain. More than 95% of Americans have suboptimal EPA + DHA blood concentrations. This cross-sectional employer-based study assessed whole blood fatty acid levels of volunteers participating in an onsite wellness biometric screening program and was designed to determine if an incentive, a $5 coupon for a 90-day supply of fish oil supplement typically costing $18–30, stimulated incremental dietary behavior change relative to nutritional status assessment alone to increase EPA + DHA concentrations. Volunteers completed a dietary survey and finger stick blood samples were collected to be analyzed for fatty acid composition. In addition, 636 individuals participated in the initial onsite biometric screening. Three months later, and without prior knowledge, all employees were invited to a second screening. At the second screening, 198 employees volunteered for the first time and 149 employees had a second test (17.9%. At baseline, the average age (n = 834 was 45 year and omega-3 index was 5.0% with 41% female. EPA + DHA concentration, i.e., omega-3 index, was significantly lower in men (4.8% than women (5.2%, as were DHA and linoleic acid (LA concentrations (p < 0.05. Baseline omega-3 index was positively and linearly associated with omega-3 intake. Only 4% of volunteers had an omega-3 index >8% on initial screening. Among the 149 individuals with two measurements, omega-3 intake from supplements, but not food, increased significantly from 258 to 445 mg/d (p < 0.01 at the second test as did the omega-3 index (+0.21, p < 0.02. In this employed population, only 1% redeemed a coupon for an omega-3 supplement.

  6. Comparison of concentrations of drugs between blood samples with and without fluoride additive-important findings for Δ9-tetrahydrocannabinol and amphetamine.

    Science.gov (United States)

    Wiedfeld, Christopher; Krueger, Julia; Skopp, Gisela; Musshoff, Frank

    2018-02-17

    Fluoride is a common stabilizing agent in forensic toxicology to avoid the frequent problem of degradation of drugs in blood samples especially described for cocaine. In cases only samples with addition of fluoride are available, it is a crucial question if also concentrations of common drugs other than cocaine (amphetamines, opiates and cannabinoids) are affected by fluoride. So far, there are only rare literature data available on discrepant results especially for Δ 9 -tetrahydrocannabinol (THC). In this study, comparative analysis of positive tested paired routine plasma/serum samples (n = 375), collected at the same time point (one device with and one without fluoride), was carried out with special focus on cannabinoids. Samples were measured with validated routine liquid chromatography-tandem mass spectrometry methods for THC, 11-hydroxy-THC (THC-OH), 11-nor-9-carboxy-THC (THC-COOH), cocaine, benzoylecgonine, ecgonine methyl ester, morphine, codeine, amphetamine, methamphetamine, 3,4-methylenedioxymethamphetamine, 3,4-methylenedioxyamphetamine, and 3,4-methylenedioxyethylamphetamine, and results were statistically evaluated. Beside the expected stabilization effect on cocaine and the consequently reduced concentration of ecgonine methyl ester in fluoride samples, benzoylecgonine was elevated compared to respective samples without fluoride. Most importantly, new findings were significantly reduced mean concentrations of THC (- 17%), THC-OH (- 17%), and THC-COOH (- 22%) in fluoride samples. Mean amphetamine concentration was significantly higher in samples with the additive (+ 6%). For the other amphetamine type of drugs as well as for morphine and codeine, no significant differences could be seen. Whenever specified thresholds have been set, such as in most European countries, the use of different blood sample systems may result in a motorist being differently charged or prosecuted. The findings will support forensic toxicologists at the

  7. SPECT measurements of cerebral blood volume before and after acetazolamide in occlusive cerebrovascular diseases

    International Nuclear Information System (INIS)

    Inoue, Yusuke; Momose, Toshimitsu; Machida, Kikuo; Honda, Norinari; Nishikawa, Junichi; Sasaki, Yasuhito.

    1994-01-01

    Cerebral blood volume before and after acetazolamide was measured by SPECT to evaluate cerebral vasodilatory capacity in eight patients with cerebrovascular disease and five control subjects. Two SPECT measurements were performed serially, and acetazolamide was administered between them. The ratio of increase in hemispheric blood volume was calculated, and it was compared with the results of cerebral blood flow and cerebral blood volume measurements. A cerebral vasodilatory capacity map, the image after acetazolamide minus the baseline image, was also produced. Acetazolamide increased hemispheric blood volume in all subjects. The ratio of increase was lower in the involved hemispheres of the patients with unilateral carotid disease than in the uninvolved hemispheres of the patients and control subjects. The ratio of concordance with blood flow and blood volume measurements was approximated at 80%. Cerebral vasodilatory capacity mapping revealed three defects compatible with the clinical data. SPECT measurements of cerebral blood volume after acetazolamide can be performed following baseline SPECT with no additional radiotracer, and may be helpful to assess hemodynamic status. (author)

  8. BREATHING 100% O2 HAS NO EFFECT ON BLOOD LACTATE CONCENTRATION DURING A SHORT PASSIVE RECOVERY FROM EXHAUSTIVE EXERCISE

    Directory of Open Access Journals (Sweden)

    Bartholomew Kay

    2005-06-01

    exercise would not affect the rate of blood LA- clearance in a relatively fit and homogenous subject pool. Seven men aged 21 ± 0 years, body mass 83 ± 19 kg [means ± SD]: peak incremental cycling power output 410 ± 19 W, [mean ± SE] were recruited on the basis of heterogeneity of maximum power output and time to exhaustion (coefficients of variation: 0.12 and 0.11 respectively. On two occasions separated by 7-days, subjects' resting blood LA- concentrations were determined at the same time of day (YSI-1500 Sport, USA following 20-minutes of postural stasis and a 12-h fast. An identical maximal-incremental power output cycle ergometer (Lode, Netherlands protocol was then used on each occasion to elicit both acute muscular exhaustion, and an accumulation blood LA-. The exercise comprised a fixed cadence of 90 RPM, starting at 50 W and increasing by 50 W·min-1 until exhaustion (or until the same period of exercise time had elapsed on the second occasion. Subjects breathed ambient air during both exercise trials. Immediately following the exercise, subjects were assisted to a chair beside the ergometer, where they remained for the next 5-minutes. During one trial, subjects breathed either ambient air or 100% O2 during the recovery period. The order of trials was randomised. Blood LA- was analyzed every minute during the 5-minute recovery periods; beginning at time 'zero' (immediately upon being seated post-exercise i.e. six samples per trial. Figure 1 illustrates the blood LA- concentration (mean ± SE for each trial at each reading. Alpha was set at 0.05. The data were subjected to three-way (treatment, time, and treatment x time ANOVA with repeated measures. The results indicate no significant effect of the treatment (p = 0.22, a significant effect of time (p = 0.0004, however no interaction was observed (p = 0.41. The current results therefore support our hypothesis. We conclude that if expedited LA- clearance from the blood provides any benefit to recovery from acute

  9. Blood Lead Concentrations in 1–3 Year Old Lebanese Children: A Cross-sectional study

    OpenAIRE

    Salem George; Mikati Mohamed; Kouzi Sarah; Muwakkit Samar; Nabulsi Mona; Nuwayhid Iman; Ariss Majd

    2003-01-01

    Abstract Background Childhood lead poisoning has not made the list of national public health priorities in Lebanon. This study aims at identifying the prevalence and risk factors for elevated blood lead concentrations (B-Pb ≥ 100 μg/L) among 1–3 year old children. It also examines the need for universal blood lead screening. Methods This is a cross-sectional study of 281 well children, presenting to the pediatric ambulatory services at the American University of Beirut Medical Center in 1997–...

  10. Determination of Microbial Nitrogen Production by Using Urinary Allantoin and Blood Metabolite Concentrate in Growing Brahman Cattle Fed the Different Proportion of Roughage and Concentrate in Diets

    International Nuclear Information System (INIS)

    Suthikrai, Wanvipa; Usawang, Sungwon; Kijsamrej, Suriya; Sophon, Sunpetch; Jetana, Thongsuk

    2003-06-01

    Determination of microbial nitrogen synthesis by using urinary allantoin and blood metabolite for evaluating the efficiency of feed utilization, in this study was conducted by using four Brahman bulls (about 1 year old). Animals were fed ad libitum with 4 fixed diets of four combinations of pineapple fibre (P) and concentrate (C) in the proportions, on dry matter basis of 0.8:0.2 (P80:C20), 0.6:0.04(P60:C40), 0.4:0.6(P40:C60) and 0.2:0.8 (P20:C80). The experiment was designed as a 4x4 Latin square design The Results showed that increasing in the proportion of concentrate linearly increased the rumen microbial nitrogen production (p<0.001), the concentrations of Insulin and urea-N in plasma and the concentration of urea-N in the urine, but not affected on the concentrations of glucose and creatinine in plasma. In conclusion, the using of allantoin urinary associated with blood metabolite can evaluate the accuracy in evaluation of feed utilization in Brahman cattle

  11. Perioperative blood saving measures in total hip and knee arthroplasty

    NARCIS (Netherlands)

    Horstmann, W.G.

    2011-01-01

    This dissertation explores and discusses different aspects of blood loss and blood-saving measures in total hip and knee arthroplasty. Background: Worldwide, approximately 1 million total hip and 1 million total knee prostheses are implanted each year. Total hip arthroplasty and total

  12. Effect of hematocrit and systolic blood pressure on cerebral blood flow in newborn infants

    International Nuclear Information System (INIS)

    Younkin, D.P.; Reivich, M.; Jaggi, J.L.; Obrist, W.D.; Delivoria-Papadopoulos, M.

    1987-01-01

    The effects of hematocrit and systolic blood pressure on cerebral blood flow were measured in 15 stable, low birth weight babies. CBF was measured with a modification of the xenon-133 ( 133 Xe) clearance technique, which uses an intravenous bolus of 133 Xe, an external chest detector to estimate arterial 133 Xe concentration, eight external cranial detectors to measure cephalic 133 Xe clearance curves, and a two-compartmental analysis of the cephalic 133 Xe clearance curves to estimate CBF. There was a significant inverse correlation between hematocrit and CBF, presumably due to alterations in arterial oxygen content and blood viscosity. Newborn CBF varied independently of systolic blood pressure between 60 and 84 mm Hg, suggesting an intact cerebrovascular autoregulatory mechanism. These results indicate that at least two of the factors that affect newborn animal CBF are operational in human newborns and may have important clinical implications

  13. Local application of 133Xenon for measurement of regional cerebral blood flow (rCBF) during halothane, enflurane, and isoflurane anesthesia in humans

    International Nuclear Information System (INIS)

    Eintrei, C.; Leszniewski, W.; Carlsson, C.

    1985-01-01

    It is well known that halothane causes an increase in cerebral blood flow (CBF). In this study the effects of halothane, enflurane, and isoflurane on regional cerebral blood flow (rCBF) in humans were determined in the presence of 70% N 2 O at a combined MAC concentration of 1.5. CBF was determined in 24 patients from the washout of locally applied 133 Xenon with the use of an external scintillation. All 24 patients (control n = 6, halothane n = 6, enflurane n = 6, and isoflurane n = 6) were undergoing neurosurgical procedures. All patients were anesthetized with thiopental, fentanyl, droperidol, and 70% N 2 O in oxygen and paralyzed with pancuronium. The measurements were performed after the dura had been opened and before definitive surgery. The first measurement was done in the absence of any volatile agent, and the wash-out curve was registered for 6 min. The second measurement was done after one of the volatile agents had been added for at least 20 min and had reached a concentration of 0.58% for halothane, 1.14% for enflurane, or 1.0% for isoflurane in the expiratory gases in order to obtain about 1.5 MAC with each volatile anesthetic. The anesthetic concentrations were measured with the Engstroem multigas analyzer EMMA. The physiologic variables changed very little throughout the period of observation. Body temperature, heart rate, blood pressure, PaCO 2 , and PaO 2 were stable. Ephedrine was used to maintain a stable arterial pressure. At approximately 1.5 MAC, halothane (plus N 2 O) increased rCBF to nearly three times (166%) the control value, while enflurane induced only a slight increase (35%) in rCBF

  14. Aquatic respiration rate measurements at low oxygen concentrations.

    Directory of Open Access Journals (Sweden)

    Moritz Holtappels

    Full Text Available Despite its huge ecological importance, microbial oxygen respiration in pelagic waters is little studied, primarily due to methodological difficulties. Respiration measurements are challenging because of the required high resolution of oxygen concentration measurements. Recent improvements in oxygen sensing techniques bear great potential to overcome these limitations. Here we compare 3 different methods to measure oxygen consumption rates at low oxygen concentrations, utilizing amperometric Clark type sensors (STOX, optical sensors (optodes, and mass spectrometry in combination with (18-18O2 labeling. Oxygen concentrations and consumption rates agreed well between the different methods when applied in the same experimental setting. Oxygen consumption rates between 30 and 400 nmol L(-1 h(-1 were measured with high precision and relative standard errors of less than 3%. Rate detection limits in the range of 1 nmol L(-1 h(-1 were suitable for rate determinations in open ocean water and were lowest at the lowest applied O2 concentration.

  15. Repeat exposure to ciguatoxin leads to enhanced and sustained thermoregulatory, pain threshold and motor activity responses in mice: relationship to blood ciguatoxin concentrations.

    Science.gov (United States)

    Bottein Dechraoui, Marie-Yasmine; Rezvani, Amir H; Gordon, Christopher J; Levin, Edward D; Ramsdell, John S

    2008-04-03

    Ciguatera is a common illness in tropical and subtropical regions that manifests in complex and long-lived symptoms which are more severe in subsequent exposures. This study measures central and peripheral neurologic signs, in parallel with blood toxin levels, in mice exposed once or twice (at 3 days interval) to a sublethal dose of ciguatoxin P-CTX-1 (0.26ng/g via i.p.). Mice were implanted with radiotransmitters to monitor motor activity and core temperature. A single exposure to ciguatoxin elicited an immediate and transient decrease in motor activity and temperature, and subsequent long-lasting thermoregulatory dysfunction resulting in stabilized body temperature around 36.0 degrees C with no observable circadian rhythm. The hypothermic response and the reduced activity were enhanced with a second exposure with 30% of the mice dying within 7h. Measurement of the peripheral nervous system by the tail flick assay revealed increased latency with a single ciguatoxin exposure, and a greater effect following the second exposure. Toxin was measurable in blood up to 3 days following the first exposure; at the 1h time point the concentrations were significantly elevated after a second exposure. These findings indicate an early response to ciguatoxin manifest in a central response to lower body temperature and reduce motor activity and a more persistent effect on the peripheral system leading to spinal heat antinociception and delayed fever-like response. The greater neurological response to a second ciguatoxin exposure was associated with elevated concentrations of ciguatoxin in the blood solely over the first hour of exposure. In conclusion, a single exposure to toxin exerts a significant neurological response which may be enhanced with subsequent exposure.

  16. Traceable measurements of the activity concentration in air

    International Nuclear Information System (INIS)

    Paul, Annette; Honig, Anja; Forkel-Wirth, Doris; Mueller, Andre; Marcos, Alicia

    2002-01-01

    The nuclear reactions induced by high energetic protons in heavy targets such as UC 2 and ThC cause a particular, complex radiation protection task at facilities like ISOLDE: the measurement of a mixture of different isotopes of the radioactive noble gas radon and the radon progenies in air. The knowledge of their respective activity concentration is fundamental for exposure assessments. Due to the complex mixture of activity concentrations in air, its precise determination is quite difficult. Therefore, a new procedure for taking reference samples was developed and implemented for the traceable measurement of the activity concentration of radioactive ions (e.g., radon progenies) in air. This technique is combined by measuring α-particles with a multi-wire ionization chamber for the parallel on-line determination of the activity concentration of different radon isotopes

  17. Grape juice concentrate prevents oxidative DNA damage in peripheral blood cells of rats subjected to a high-cholesterol diet.

    Science.gov (United States)

    Aguiar, Odair; Gollücke, Andréa Pittelli Boiago; de Moraes, Bárbara Bueno; Pasquini, Gabriela; Catharino, Rodrigo Ramos; Riccio, Maria Francesca; Ihara, Silvia Saiuli Miki; Ribeiro, Daniel Araki

    2011-03-01

    The goal of the present study was to investigate whether subchronic treatment with grape juice concentrate is able to protect liver and peripheral blood cells against cholesterol-induced injury in rats. The effects of the grape juice concentrate treatment on histopathological changes, immunohistochemistry for cyclo-oxygenase-2 (COX-2), and basal and oxidative DNA damage induced by H2O2 using a single-cell gel (comet) assay were evaluated. Male Wistar rats (n 18) were divided into three groups: group 1--negative control; group 2--cholesterol at 1 % (w/w) in their diet, treated for 5 weeks; group 3--cholesterol at 1 % in their chow, treated for 5 weeks, and grape juice concentrate at 222 mg/d in their drinking-water in the final week only. The results indicated that the treatment with grape juice concentrate did not show remarkable differences regarding liver tissue in group 3 compared with group 2. However, grape juice concentrate was able to decrease oxidative DNA damage induced by H2O2 in peripheral blood cells, as depicted by the tail moment results. COX-2 expression in the liver did not show statistically significant differences (P>0·05) between groups. Taken together, the present results suggest that the administration of subchronic grape juice concentrate prevents oxidative DNA damage in peripheral blood cells.

  18. Influence of drugs of abuse and alcohol upon patients admitted to acute psychiatric wards: physician's assessment compared to blood drug concentrations.

    Science.gov (United States)

    Mordal, Jon; Medhus, Sigrid; Holm, Bjørn; Mørland, Jørg; Bramness, Jørgen G

    2013-06-01

    In acute psychiatric services, rapid and accurate detection of psychoactive substance intake may be required for appropriate diagnosis and intervention. The aim of this study was to investigate the relationship between (a) drug influence as assessed by physicians and (b) blood drug concentrations among patients admitted to acute psychiatric wards. We also explored the possible effects of age, sex, and psychotic symptoms on physician's assessment of drug influence. In a cross-sectional study, the sample comprised 271 consecutive admissions from 2 acute psychiatric wards. At admission, the physician on call performed an overall judgment of drug influence. Psychotic symptoms were assessed with the positive subscale of the Positive and Negative Syndrome Scale. Blood samples were screened for a wide range of psychoactive substances, and quantitative results were used to calculate blood drug concentration scores. Patients were judged as being under the influence of drugs and/or alcohol in 28% of the 271 admissions. Psychoactive substances were detected in 56% of the blood samples. Altogether, 15 different substances were found; up to 8 substances were found in samples from 1 patient. Markedly elevated blood drug concentration scores were estimated for 15% of the patients. Physician's assessment was positively related to the blood drug concentration scores (r = 0.52; P < 0.001), to symptoms of excitement, and to the detection of alcohol, cannabis, and amphetamines. The study demonstrates the major impact of alcohol and drugs in acute psychiatric settings and illustrates the challenging nature of the initial clinical assessment.

  19. Effects of barium concentration on oropharyngeal swallow timing measures.

    Science.gov (United States)

    Stokely, Shauna L; Molfenter, Sonja M; Steele, Catriona M

    2014-02-01

    Videofluoroscopy is commonly used for evaluating oropharyngeal swallowing but requires radiopaque contrast (typically barium). Prior studies suggest that some aspects of swallowing, including timing measures of oral and pharyngeal bolus transit, vary depending on barium concentration. The aim of our study was to identify timing differences in healthy swallowing between "thin" (40 % w/v concentration) and "ultrathin" (22 % w/v concentration) barium solutions. Twenty healthy adults (Ten women; mean age = 31 years) each performed a series of three noncued 5-ml swallows each of ultrathin and thin liquid barium solutions in videofluoroscopy. Timing measures were compared between barium concentrations using a mixed-model ANOVA. The measures of interest were stage transition duration, pharyngeal transit time, and duration of upper esophageal sphincter opening. Significant differences were observed in the timing measures of swallowing with respect to barium concentration. In all cases, longer durations were seen with the higher barium concentration. Barium concentration influences timing parameters in healthy swallowing, even between ultrathin and thin concentrations. Clinicians need to understand and control for the impact of different barium stimuli on swallowing physiology.

  20. Fetal plasma erythropoietin concentration in severe growth retardation.

    Science.gov (United States)

    Snijders, R J; Abbas, A; Melby, O; Ireland, R M; Nicolaides, K H

    1993-02-01

    The aim of this study was to determine whether hypoxemia induces an increase in plasma erythropoietin concentration in human fetal life and, if so, whether this response stimulates fetal erythropoiesis. The plasma erythropoietin concentration in blood samples from 33 small-for-gestational-age fetuses at 26 to 38 weeks' gestation was measured. Measurements were compared with the reference range for gestation, and associations with PO2, pH, and erythroblast and erythrocyte counts were examined. The mean plasma erythropoietin concentration in the small-for-gestational-age fetuses was significantly increased, and the degree of increase was significantly associated both with fetal acidemia and, more strongly, with fetal erythroblastosis. Erythropoietin production in response to tissue hypoxia occurs from at least 26 weeks' gestation with measurable physiologic effects on erythropoiesis. Furthermore, more accurate assessment of tissue oxygenation may be obtained by measuring the erythroblast count rather than the blood pH.

  1. Pulmonary blood flow distribution measured by radionuclide computed tomography

    International Nuclear Information System (INIS)

    Maeda, H.; Itoh, H.; Ishii, Y.

    1982-01-01

    Distributions of pulmonary blood flow per unit lung volume were measured in sitting patients with a radionuclide computed tomography (RCT) by intravenously administered Tc-99m macroaggregates of human serum albumin (MAA). Four different types of distribution were distinguished, among which a group referred as type 2 had a three zonal blood flow distribution as previously reported (West and co-workers, 1964). The pulmonary arterial pressure (Pa) and the venous pressure (Pv) were determined in this group of distribution. These values showed satifactory agreements with the pulmonary artery pressure (Par) and the capillary wedged pressure (Pcw) measured by Swan-Ganz catheter in eighteen supine patients. Those good correlations enable to establish a noninvasive methodology for measurement of pulmonary vascular pressures

  2. Simple Radiowave-Based Method For Measuring Peripheral Blood Flow Project

    Science.gov (United States)

    Oliva-Buisson, Yvette J.

    2014-01-01

    Project objective is to design small radio frequency based flow probes for the measurement of blood flow velocity in peripheral arteries such as the femoral artery and middle cerebral artery. The result will be the technological capability to measure peripheral blood flow rates and flow changes during various environmental stressors such as microgravity without contact to the individual being monitored. This technology may also lead to an easier method of detecting venous gas emboli during extravehicular activities.

  3. HbA1c measurements from dried blood spots : validation and patient satisfaction

    NARCIS (Netherlands)

    Fokkema, Margaretha; Bakker, Andries J; de Boer, Fokje; Kooistra, Jeltsje; de Vries, Sifra; Wolthuis, Albert

    2009-01-01

    Background: This study evaluates HbA1c measurements from dried blood spots collected on filter paper and compares HbA1c from filter paper (capillary blood) with HbA1c measured in venous blood. Methods: Patient satisfaction was evaluated using a questionnaire. The performance with the filter paper

  4. Directly measuring spinal cord blood flow and spinal cord perfusion pressure via the collateral network: correlations with changes in systemic blood pressure.

    Science.gov (United States)

    Kise, Yuya; Kuniyoshi, Yukio; Inafuku, Hitoshi; Nagano, Takaaki; Hirayasu, Tsuneo; Yamashiro, Satoshi

    2015-01-01

    During thoracoabdominal surgery in which segmental arteries are sacrificed over a large area, blood supply routes from collateral networks have received attention as a means of avoiding spinal cord injury. The aim of this study was to investigate spinal cord blood supply through a collateral network by directly measuring spinal cord blood flow and spinal cord perfusion pressure experimentally. In beagle dogs (n = 8), the thoracoabdominal aorta and segmental arteries L1-L7 were exposed, and a temporary bypass was created for distal perfusion. Next, a laser blood flow meter was placed on the spinal dura mater in the L5 region to measure the spinal cord blood flow. The following were measured simultaneously when the direct blood supply from segmental arteries L2-L7 to the spinal cord was stopped: mean systemic blood pressure, spinal cord perfusion pressure (blood pressure within the aortic clamp site), and spinal cord blood flow supplied via the collateral network. These variables were then investigated for evidence of correlations. Positive correlations were observed between mean systemic blood pressure and spinal cord blood flow during interruption of segmental artery flow both with (r = 0.844, P flow with and without distal perfusion (r = 0.803, P network from outside the interrupted segmental arteries, and high systemic blood pressure (∼1.33-fold higher) was needed to obtain the preclamping spinal cord blood flow, whereas 1.68-fold higher systemic blood pressure was needed when distal perfusion was halted. Spinal cord blood flow is positively correlated with mean systemic blood pressure and spinal cord perfusion pressure under spinal cord ischemia caused by clamping a wide range of segmental arteries. In open and endovascular thoracic and thoracoabdominal surgery, elevating mean systemic blood pressure is a simple and effective means of increasing spinal cord blood flow, and measuring spinal cord perfusion pressure seems to be useful for monitoring

  5. Effect of prewarming the forearm on the measurement of regional cerebral blood flow with one-point venous sampling by autoradiography method

    International Nuclear Information System (INIS)

    Itoh, Youko H.; Kurabe, Teruhisa; Kazaoka, Yoshiaki; Ishiguchi, Tsuneo; Kawashima, Sadao

    2004-01-01

    Autoradiography (ARG) using 123 I-iodoamphetamine ( 123 I-IMP) is widely performed as an efficient method of measuring local cerebral blood flow. Recently, ARG by a single collection of venous blood has been appreciated as a simple method. In this study, we investigated the effect of warming of the site for collecting venous blood (forearm). The coefficient of correlation of the local cerebral blood flow value obtained from arterial and venous blood samples was 0.766 (p<0.05) in the group without warming (38 patients). The coefficient of correlation similarly obtained in the group with warming (53 patients) was 0.908 (p<0.05). The difference in the correlation efficient was significant (p<0.05) between the two groups. From these results it was concluded that warming the blood-collecting site decreased the difference between the arterial and venous radioactive concentrations and increased the precision of the test. (author)

  6. Blood harmane (1-methyl-9H-pyrido[3,4-b]indole) concentrations in essential tremor: repeat observation in cases and controls in New York.

    Science.gov (United States)

    Louis, Elan D; Jiang, Wendy; Gerbin, Marina; Viner, Amanda S; Factor-Litvak, Pam; Zheng, Wei

    2012-01-01

    Essential tremor (ET) is a widespread late-life neurological disease. Genetic and environmental factors are likely to play important etiological roles. Harmane (1-methyl-9H-pyrido[3,4-b]indole) is a potent tremor-producing neurotoxin. Previously, elevated blood harmane concentrations were demonstrated in ET cases compared to controls, but these observations have all been cross-sectional, assessing each subject at only one time point. Thus, no one has ever repeat-assayed blood harmane in the same subjects twice. Whether the observed case-control difference persists at a second time point, years later, is unknown. The current goal was to reassess a sample of our ET cases and controls to determine whether blood harmane concentration remained elevated in ET at a second time point. Blood harmane concentrations were quantified by a well-established high-performance liquid chromatography method in 63 ET cases and 70 controls. A mean of approximately 6 yr elapsed between the initial and this subsequent blood harmane determination. The mean log blood harmane concentration was significantly higher in cases than controls (0.30 ± 0.61 g(-10)/ml versus 0.08 ± 0.55 g(-10)/ml), and the median value in cases was double that of controls: 0.22 g(-10)/ml versus 0.11 g(-10)/ml. The log blood harmane concentration was highest in cases with a family history of ET. Blood harmane concentration was elevated in ET cases compared to controls when reassessed at a second time point several years later, indicating what seems to be a stable association between this environmental toxin and ET.

  7. Optical sensor technology for a noninvasive continuous monitoring of blood components

    Science.gov (United States)

    Kraitl, Jens; Timm, Ulrich; Lewis, Elfed; Ewald, Hartmut

    2010-02-01

    NIR-spectroscopy and Photoplethysmography (PPG) is used for a measurement of blood components. The absorptioncoefficient of blood differs at different wavelengths. This fact is used to calculate the optical absorbability characteristics of blood which is yielding information about blood components like hemoglobin (Hb), carboxyhemoglobin (CoHb) and arterial oxygen saturation (SpO2). The measured PPG time signals and the ratio between the peak to peak pulse amplitudes are used for a measurement of these parameters. Hemoglobin is the main component of red blood cells. The primary function of Hb is the transport of oxygen from the lungs to the tissue and carbon dioxide back to the lungs. The Hb concentration in human blood is an important parameter in evaluating the physiological status of an individual and an essential parameter in every blood count. Currently, invasive methods are used to measure the Hb concentration, whereby blood is taken from the patient and subsequently analyzed. Apart from the discomfort of drawing blood samples, an added disadvantage of this method is the delay between the blood collection and its analysis, which does not allow real time patient monitoring in critical situations. A noninvasive method allows pain free continuous on-line patient monitoring with minimum risk of infection and facilitates real time data monitoring allowing immediate clinical reaction to the measured data.

  8. The position of the arm during blood pressure measurement in sitting position.

    NARCIS (Netherlands)

    Adiyaman, A.; Verhoeff, R.; Lenders, J.W.M.; Deinum, J.; Thien, Th.

    2006-01-01

    OBJECTIVE: Determining the influence of the position of the arm on blood pressure measurement in the sitting position. METHODS: Blood pressure of 128 individuals (the majority being treated hypertensive patients) visiting the outpatient clinic was measured simultaneously on both arms with arms in

  9. Effect of feeding glucose, fructose, and inulin on blood glucose and insulin concentrations in normal ponies and those predisposed to laminitis.

    Science.gov (United States)

    Borer, K E; Bailey, S R; Menzies-Gow, N J; Harris, P A; Elliott, J

    2012-09-01

    Identification of ponies (Equus caballus) at increased risk of pasture-associated laminitis would aid in the prevention of the disease. Insulin resistance has been associated with laminitis and could be used to identify susceptible individuals. Insulin resistance may be diagnosed by feeding supplementary water-soluble carbohydrate (WSC) and measuring blood glucose and insulin concentrations. The aim of this study was to assess the glycemic and insulinemic responses of 7 normal (NP) and 5 previously laminitic (PLP), mixed breed, native UK ponies fed glucose, fructose, and inulin [1 g/(kg·d) for 3 d] or no supplementary WSC (control) in spring and fall after a 7-d adaptation to a pasture or hay diet. Blood samples were taken for 12 h after feeding on each day, and baseline and peak concentrations and area under the curve (AUC) for glucose and insulin were recorded. Linear mixed models were used for statistical analysis. Differences between PLP and NP groups were most marked after glucose feeding with differences in peak glucose (P = 0.02) and peak insulin (P = 0.016) concentrations. Season and diet adaptation also affected results. Peak concentrations of glucose and insulin occurred 2 to 4 h after WSC feeding. Peak insulin concentration was greater and more variable in fall, particularly in PLP adapted to fall pasture. Baseline glucose and insulin concentrations varied between individuals and with season and diet adaptation but were not greater in PLP than NP. Insulin AUC was greater in PLP than NP after feeding both glucose and fructose (P = 0.017), but there were no differences between PLP and NP in glucose AUC. Glycemic and insulinemic changes were less (P ≤ 0.05) after feeding fructose than glucose, although differences between PLP and NP were still evident. Minimal changes in glucose and insulin concentrations occurred after inulin feeding. Measurement of peak insulin 2 h after feeding of a single dose of glucose (1 g/kg) may be a simple and practical way to

  10. Limitations of quantitative photoacoustic measurements of blood oxygenation in small vessels

    International Nuclear Information System (INIS)

    Sivaramakrishnan, Mathangi; Maslov, Konstantin; Zhang, Hao F; Stoica, George; Wang, Lihong V

    2007-01-01

    We investigate the feasibility of obtaining accurate quantitative information, such as local blood oxygenation level (sO 2 ), with a spatial resolution of about 50 μm from spectral photoacoustic (PA) measurements. The optical wavelength dependence of the peak values of the PA signals is utilized to obtain the local blood oxygenation level. In our in vitro experimental models, the PA signal amplitude is found to be linearly proportional to the blood optical absorption coefficient when using ultrasonic transducers with central frequencies high enough such that the ultrasonic wavelengths are shorter than the light penetration depth into the blood vessels. For an optical wavelength in the 578-596 nm region, with a transducer central frequency that is above 25 MHz, the sensitivity and accuracy of sO 2 inversion is shown to be better than 4%. The effect of the transducer focal position on the accuracy of quantifying blood oxygenation is found to be negligible. In vivo oxygenation measurements of rat skin microvasculature yield results consistent with those from in vitro studies, although factors specific to in vivo measurements, such as the spectral dependence of tissue optical attenuation, dramatically affect the accuracy of sO 2 quantification in vivo

  11. Nurse-measured or ambulatory blood pressure in routine hypertension care

    NARCIS (Netherlands)

    Veerman, D. P.; van Montfrans, G. A.

    1993-01-01

    Nurses are considered to evoke less white-coat hypertension, and might therefore be able to estimate average blood pressure as well as and more conveniently than ambulatory monitoring. The objective of the present study was to determine the correspondence between blood pressure measured by a doctor

  12. Immunoproteasome in the blood plasma of children with acute appendicitis, and its correlation with proteasome and UCHL1 measured by SPR imaging biosensors.

    Science.gov (United States)

    Matuszczak, E; Sankiewicz, A; Debek, W; Gorodkiewicz, E; Milewski, R; Hermanowicz, A

    2018-01-01

    The aim of this study was to determinate the immunoproteasome concentration in the blood plasma of children with appendicitis, and its correlation with circulating proteasome and ubiquitin carboxyl-terminal hydrolase L1 (UCHL1). Twenty-seven children with acute appendicitis, managed at the Paediatric Surgery Department, were included randomly into the study (age 2 years 9 months up to 14 years, mean age 9·5 ± 1 years). There were 10 girls and 17 boys; 18 healthy, age-matched subjects, admitted for planned surgeries served as controls. Mean concentrations of immunoproteasome, 20S proteasome and UCHL1 in the blood plasma of children with appendicitis before surgery 24 h and 72 h after the appendectomy were higher than in the control group. The immunoproteasome, 20S proteasome and UCHL1 concentrations in the blood plasma of patients with acute appendicitis were highest before surgery. The immunoproteasome, 20S proteasome and UCHL1 concentration measured 24 and 72 h after the operation decreased slowly over time and still did not reach the normal range (P appendicitis. © 2017 British Society for Immunology.

  13. Traceable measurements of the activity concentration in air

    CERN Document Server

    Paul, A; Forkel-Wirth, Doris; Müller, A; Marcos, A

    2002-01-01

    The nuclear reactions induced by high energetic protons in heavy targets such as UC/sub 2/ and ThC cause a particular, complex radiation protection task at facilities like ISOLDE: the measurement of a mixture of different isotopes of the radioactive noble gas radon and the radon progenies in air. The knowledge of their respective activity concentration is fundamental for exposure assessments. Due to the complex mixture of activity concentrations in air, its precise determination is quite difficult. Therefore, a new procedure for taking reference samples was developed and implemented for the traceable measurement of the activity concentration of radioactive ions (e.g., radon progenies) in air. This technique is combined by measuring alpha -particles with a multi-wire ionization chamber for the parallel on-line determination of the activity concentration of different radon isotopes. (10 refs).

  14. Comparative study of the concentration of salivary and blood glucose in type 2 diabetic patients.

    Science.gov (United States)

    Vasconcelos, Ana Carolina U; Soares, Maria Sueli M; Almeida, Paulo C; Soares, Teresa C

    2010-06-01

    The objective of the present study was to comparatively evaluate the concentrations of blood and salivary glucose as well as salivary flow and xerostomia in type 2 diabetic and non-diabetic patients. The mean salivary glucose level in diabetic patients was 14.03 +/-16.76 mg/dl and 6.35 +/- 6.02 mg/dl (P = 0.036) in the control group. The mean capillary blood glucose level in diabetic patients was 213 +/- 88 mg/dl, while that in non-diabetic patients was 99 +/- 14 mg/dl (P = 0.000). The mean value for resting salivary flow was 0.21 +/- 0.16 ml/min in diabetic patients and 0.33 +/- 0.20 ml/min in the control group (P = 0.002). The stimulated salivary flow was lower in the group of diabetic patients, with a mean of 0.63 +/- 0.43 ml/min, whereas the control group showed a mean of 1.20 +/- 0.70 ml/min (P = 0.000). Of the diabetic patients, 45% exhibited hyposalivation, in contrast to 2.5% of the non-diabetic patients (P = 0.000). Xerostomia was reported in 12.5% of diabetic patients and 5% of non-diabetic patients (P = 0.23). We can conclude that salivary glucose concentration was significantly higher in the experimental group and that there was no correlation between salivary and blood glucose concentrations in diabetic patients. The total salivary flow was significantly reduced in diabetic patients and there was no significant difference as to the presence of xerostomia in both groups.

  15. Evaluation of hematologic, blood gas, and select biochemical variables in ovine whole blood stored in CPDA-1 bags.

    Science.gov (United States)

    Sousa, Rejane S; Barrêto, Raimundo A; Sousa, Isadora K F; Chaves, Dowglish F; Soares, Herbert S; Barros, Isabella O; Minervino, Antonio H H; Ortolani, Enrico L

    2013-03-01

    The economic consequences from mortality of sheep after blood loss can be considerable. To date there are no reports addressing hematologic, blood gas, and biochemical changes in ovine blood stored in CPDA-1 bags. The aim of this study was to investigate hematologic, blood gas, and biochemical alterations resulting from storage of ovine blood in CPDA-1 bags to establish transfusion protocols in sheep. From each of 7 healthy 8-month-old sheep 450 mL of blood were collected into CPDA-1 bags and stored for 35 days in at 3-6°C. Samples were taken from the bags at days 0, 7, 14, 21, and 35. Whole blood was used to assess PCV, MCV, RBC count, pH, pO2 , pCO2 , and concentrations of bicarbonate, sodium, and lactate. Plasma was used to measure potassium, hemoglobin, and glucose concentrations. The PCV remained stable throughout the storage period, while plasma hemoglobin and MCV began to increase on days 7 and 21, respectively. The RBC count began to decrease on day 21. Blood pH decreased and pCO2 increased steadily throughout the storage period. Potassium concentration increased from 3.8 to 18.3 mmol/L on day 7 and remained high thereafter. In contrast, sodium concentration began to decrease on day 7. The results show that ovine blood undergoes hematologic, blood gas, and biochemical changes during storage. Further studies are required to establish RBC viability in CPDA-1 bags after a storage period of 35 days. © 2012 American Society for Veterinary Clinical Pathology.

  16. Relationship between haemoglobin concentration and packed cell volume in cattle blood samples

    Directory of Open Access Journals (Sweden)

    Paa-Kobina Turkson

    2015-02-01

    Full Text Available A convention that has been adopted in medicine is to estimate haemoglobin (HB concentration as a third of packed cell volume (PCV or vice versa. The present research set out to determine whether a proportional relationship exists between PCV and Hb concentration in cattle blood samples, and to assess the validity of the convention of estimating Hb concentration as a third of PCV. A total of 440 cattle in Ghana from four breeds (Ndama, 110; West African Short Horn, 110; Zebu, 110 and Sanga, 110 were bled for haematological analysis, specifically packed cell volume, using the microhaematocrit technique and haemoglobin concentration using the cyanmethaemoglobin method. Means, standard deviations, standard errors of mean and 95% confidence intervals were calculated. Trendline analyses generated linear regression equations from scatterplots. For all the cattle, a significant and consistent relationship (r = 0.74 was found between Hb concentration and PCV (%. This was expressed as Hb concentration (g/dL = 0.28 PCV + 3.11. When the Hb concentration was estimated by calculating it as a third of PCV, the relationship was expressed in linear regression as Hb concentration (g/dL = 0.83 calculated Hb + 3.11. The difference in the means of determined (12.2 g/dL and calculated (10.9 g/dL Hb concentrations for all cattle was significant (p < 0.001, whereas the difference in the means of determined Hb and corrected calculated Hb was not significant. In conclusion, a simplified relationship of Hb (g/dL = (0.3 PCV + 3 may provide a better estimate of Hb concentration from the PCV of cattle.

  17. Blood lactate recovery measurements, training, and performance during a 23-week period of competitive swimming.

    Science.gov (United States)

    Pelayo, P; Mujika, I; Sidney, M; Chatard, J C

    1996-01-01

    The purpose of this study was to relate measurements of blood lactate concentration, performance during a maximal anaerobic lactic test (MANLT) and training loads during a 23-week swimming season. Six elite 200-m freestyle male swimmers [mean age 19.5 (SD 1.6) years, height 184 (SD 5) cm and body mass 77.7 (SD 9.0) kg], participated in the study. The MANLT consisted of four all-out 50-m swims interspersed with 10-s recovery periods. Blood lactate concentrations were determined at 3 and 12-min post-exercise and were performed on weeks 2,6,10,14,18 and 21. Swimmers participated in 200-m freestyle competitions on weeks 1,7,13 and 23 (national championships). During weeks 1-10, training mostly involved aerobic exercise, while during weeks, 11-23, it involved anaerobic exercise. At 3-min and 12-min post-MANLT lactate concentrations varied throughout the season [range from 14.9 (SD 1.2) to 18.7 (SD 1.0) mmol.l-1] but demonstrated non-systematic variations. In contrast, the percentage of mean blood lactate decrease (% [La-]recovery) between min 3 and min 12 of the passive recovery post-MANLT increased from week 2 to 10 with aerobic training and decreased from week 10 to 21 with anaerobic training. The MANLT performance improved continuously throughout the season, while competition performance improved during the first three competitions but declined in the final championships, coinciding with the lowest % [La-]recovery and signs of overtraining, such as bad temper and increased sleeping heart rate. The results of this study indicated that % [La-]recovery could be an efficient marker for monitoring the impact of aerobic and anaerobic training and avoiding overtraining in elite 200-m swimmers.

  18. The impact of arm position on the measurement of orthostatic blood pressure.

    Science.gov (United States)

    Guss, David A; Abdelnur, Diego; Hemingway, Thomas J

    2008-05-01

    Blood pressure is a standard vital sign in patients evaluated in an Emergency Department. The American Heart Association has recommended a preferred position of the arm and cuff when measuring blood pressure. There is no formal recommendation for arm position when measuring orthostatic blood pressure. The objective of this study was to assess the impact of different arm positions on the measurement of postural changes in blood pressure. This was a prospective, unblinded, convenience study involving Emergency Department patients with complaints unrelated to cardiovascular instability. Repeated blood pressure measurements were obtained using an automatic non-invasive device with each subject in a supine and standing position and with the arm parallel and perpendicular to the torso. Orthostatic hypotension was defined as a difference of >or= 20 mm Hg systolic or >or= 10 mm Hg diastolic when subtracting standing from supine measurements. There were four comparisons made: group W, arm perpendicular supine and standing; group X, arm parallel supine and standing; group Y, arm parallel supine and perpendicular standing; and group Z, arm perpendicular supine and parallel standing. There were 100 patients enrolled, 55 men, mean age 44 years. Four blood pressure measurements were obtained on each patient. The percentage of patients meeting orthostatic hypotension criteria in each group was: W systolic 6% (95% CI 1%, 11%), diastolic 4% (95% CI 0%, 8%), X systolic 8% (95% CI 3%, 13%), diastolic 9% (95% CI 3%, 13%), Y systolic 19% (95% CI 11%, 27%), diastolic 30% (95% CI 21%, 39%), Z systolic 2% (95% CI 0%, 5%), diastolic 2% (95% CI 0%, 5%). Comparison of Group Y vs. X, Z, and W was statistically significant (p postural changes in blood pressure. The combination of the arm parallel when supine and perpendicular when standing may significantly overestimate the orthostatic change. Arm position should be held constant in supine and standing positions when assessing for orthostatic

  19. Prospective blood pressure measurement in renal transplant recipients.

    Science.gov (United States)

    David, V G; Yadav, B; Jeyaseelan, L; Deborah, M N; Jacob, S; Alexander, S; Varughese, S; John, G T

    2014-05-01

    Blood pressure (BP) control at home is difficult when managed only with office blood pressure monitoring (OBPM). In this prospective study, the reliability of BP measurements in renal transplant patients with OBPM and home blood pressure monitoring (HBPM) was compared with ambulatory blood pressure monitoring (ABPM) as the gold standard. Adult patients who had living-related renal transplantation from March 2007 to February 2008 had BP measured by two methods; OBPM and ABPM at pretransplantation, 2(nd), 4(th), 6(th), and 9(th) months and all the three methods: OBPM, ABPM, and HBPM at 6 months after transplantation. A total of 49 patients, age 35 ± 11 years, on prednisolone, tacrolimus, and mycophenolate were evaluated. A total of 39 were males (79.6%). Systolic BP (SBP) and diastolic BP (DBP) measured by OBPM were higher than HBPM when compared with ABPM. When assessed using OBPM and awake ABPM, both SBP and DBP were significantly overestimated by OBPM with mean difference of 3-12 mm Hg by office SBP and 6-8 mm Hg for office DBP. When HBPM was compared with mean ABPM at 6 months both the SBP and DBP were overestimated by and 7 mm Hg respectively. At 6 months post transplantation, when compared with ABPM, OBPM was more specific than HBPM in diagnosing hypertension (98% specificity, Kappa: 0.88 vs. 89% specificity, Kappa: 0.71). HBPM was superior to OBPM in identifying patients achieving goal BP (89% specificity, Kappa: 0.71 vs. 50% specificity Kappa: 0.54). In the absence of a gold standard for comparison the latent class model analysis still showed that ABPM was the best tool for diagnosing hypertension and monitoring patients reaching targeted control. OBPM remains an important tool for the diagnosis and management of hypertension in renal transplant recipients. HBPM and ABPM could be used to achieve BP control.

  20. Prospective blood pressure measurement in renal transplant recipients

    Directory of Open Access Journals (Sweden)

    V G David

    2014-01-01

    Full Text Available Blood pressure (BP control at home is difficult when managed only with office blood pressure monitoring (OBPM. In this prospective study, the reliability of BP measurements in renal transplant patients with OBPM and home blood pressure monitoring (HBPM was compared with ambulatory blood pressure monitoring (ABPM as the gold standard. Adult patients who had living-related renal transplantation from March 2007 to February 2008 had BP measured by two methods; OBPM and ABPM at pretransplantation, 2 nd , 4 th , 6 th , and 9 th months and all the three methods : OBPM, ABPM, and HBPM at 6 months after transplantation. A total of 49 patients, age 35 ± 11 years, on prednisolone, tacrolimus, and mycophenolate were evaluated. A total of 39 were males (79.6%. Systolic BP (SBP and diastolic BP (DBP measured by OBPM were higher than HBPM when compared with ABPM. When assessed using OBPM and awake ABPM, both SBP and DBP were significantly overestimated by OBPM with mean difference of 3-12 mm Hg by office SBP and 6-8 mm Hg for office DBP. When HBPM was compared with mean ABPM at 6 months both the SBP and DBP were overestimated by and 7 mm Hg respectively. At 6 months post transplantation, when compared with ABPM, OBPM was more specific than HBPM in diagnosing hypertension (98% specificity, Kappa : 0.88 vs. 89% specificity, Kappa : 0.71. HBPM was superior to OBPM in identifying patients achieving goal BP (89% specificity, Kappa : 0.71 vs. 50% specificity Kappa : 0.54. In the absence of a gold standard for comparison the latent class model analysis still showed that ABPM was the best tool for diagnosing hypertension and monitoring patients reaching targeted control. OBPM remains an important tool for the diagnosis and management of hypertension in renal transplant recipients. HBPM and ABPM could be used to achieve BP control.

  1. A microfluidic approach for hemoglobin detection in whole blood

    Directory of Open Access Journals (Sweden)

    Nikita Taparia

    2017-10-01

    Full Text Available Diagnosis of anemia relies on the detection of hemoglobin levels in a blood sample. Conventional blood analyzers are not readily available in most low-resource regions where anemia is prevalent, so detection methods that are low-cost and point-of-care are needed. Here, we present a microfluidic approach to measure hemoglobin concentration in a sample of whole blood. Unlike conventional approaches, our microfluidic approach does not require hemolysis. We detect the level of hemoglobin in a blood sample optically by illuminating the blood in a microfluidic channel at a peak wavelength of 540 nm and measuring its absorbance using a CMOS sensor coupled with a lens to magnify the image onto the detector. We compare measurements in microchannels with channel heights of 50 and 115 μm and found the channel with the 50 μm height provided a better range of detection. Since we use whole blood and not lysed blood, we fit our data to an absorption model that includes optical scattering in order to obtain a calibration curve for our system. Based on this calibration curve and data collected, we can measure hemoglobin concentration within 1 g/dL for severe cases of anemia. In addition, we measured optical density for blood flowing at a shear rate of 500 s-1 and observed it did not affect the nonlinear model. With this method, we provide an approach that uses microfluidic detection of hemoglobin levels that can be integrated with other microfluidic approaches for blood analysis.

  2. A microfluidic approach for hemoglobin detection in whole blood

    Science.gov (United States)

    Taparia, Nikita; Platten, Kimsey C.; Anderson, Kristin B.; Sniadecki, Nathan J.

    2017-10-01

    Diagnosis of anemia relies on the detection of hemoglobin levels in a blood sample. Conventional blood analyzers are not readily available in most low-resource regions where anemia is prevalent, so detection methods that are low-cost and point-of-care are needed. Here, we present a microfluidic approach to measure hemoglobin concentration in a sample of whole blood. Unlike conventional approaches, our microfluidic approach does not require hemolysis. We detect the level of hemoglobin in a blood sample optically by illuminating the blood in a microfluidic channel at a peak wavelength of 540 nm and measuring its absorbance using a CMOS sensor coupled with a lens to magnify the image onto the detector. We compare measurements in microchannels with channel heights of 50 and 115 μm and found the channel with the 50 μm height provided a better range of detection. Since we use whole blood and not lysed blood, we fit our data to an absorption model that includes optical scattering in order to obtain a calibration curve for our system. Based on this calibration curve and data collected, we can measure hemoglobin concentration within 1 g/dL for severe cases of anemia. In addition, we measured optical density for blood flowing at a shear rate of 500 s-1 and observed it did not affect the nonlinear model. With this method, we provide an approach that uses microfluidic detection of hemoglobin levels that can be integrated with other microfluidic approaches for blood analysis.

  3. Automatic Blood Pressure Measurements During Exercise

    Science.gov (United States)

    Weaver, Charles S.

    1985-01-01

    Microprocessor circuits and a computer algorithm for automatically measuring blood pressure during ambulatory monitoring and exercise stress testing have been under development at SRI International. A system that records ECG, Korotkov sound, and arm cuff pressure for off-line calculation of blood pressure has been delivered to NASA, and an LSLE physiological monitoring system that performs the algorithm calculations in real-time is being constructed. The algorithm measures the time between the R-wave peaks and the corresponding Korotkov sound on-set (RK-interval). Since the curve of RK-interval versus cuff pressure during deflation is predictable and slowly varying, windows can be set around the curve to eliminate false Korotkov sound detections that result from noise. The slope of this curve, which will generally decrease during exercise, is the inverse of the systolic slope of the brachial artery pulse. In measurements taken during treadmill stress testing, the changes in slopes of subjects with coronary artery disease were markedly different from the changes in slopes of healthy subjects. Measurements of slope and O2 consumption were also made before and after ten days of bed rest during NASA/Ames Research Center bed rest studies. Typically, the maximum rate of O2 consumption during the post-bed rest test is less than the maximum rate during the pre-bed rest test. The post-bed rest slope changes differ from the pre-bed rest slope changes, and the differences are highly correlated with the drop in the maximum rate of O2 consumption. We speculate that the differences between pre- and post-bed rest slopes are due to a drop in heart contractility.

  4. Student drinking patterns and blood alcohol concentration on commercially organised pub crawls in the UK.

    Science.gov (United States)

    Quigg, Zara; Hughes, Karen; Bellis, Mark A

    2013-12-01

    Commercial student pub crawls are associated with high levels of alcohol consumption, and are of growing concern amongst public health and student bodies. However, little is currently known about drinking behaviours whilst participating in these events. A questionnaire was implemented amongst 227 students attending commercial pub crawls across three UK events. Questions established alcohol consumption patterns up to the point of interview and throughout the remaining night out, and pub crawl experience. Breathalyser tests were used to measure breath alcohol concentration (converted to blood alcohol concentration [BAC]) at interview. Analyses used chi squared, Mann-Whitney U, Kruskal-Wallis and logistic regression. 94.3% of participants had consumed alcohol, 90.9% of whom reported preloading. Drinkers reported consuming a median of 10.0 alcohol units (80g of pure alcohol) up to the point of interview (range one-40.6), with estimated total consumption over the evening exceeding 16units (range three-70.6). Median BAC of drinkers at the time of interview was 0.10%BAC (range 0.00-0.27). High BAC (>0.08%; at interview) was associated with having not eaten food in the four hours prior (AOR 4.8, palcohol consumption before and during commercial pub crawls should aim to alter drinking behaviours such as preloading and rapid and excessive drinking. Organisers, local authorities, universities and students should all be involved in ensuring the effective management of pub crawls, including implementation of harm prevention measures. © 2013.

  5. Is there a necessity for individual blood water corrections when conductivity-based access blood flow measurements are made?

    Science.gov (United States)

    Huang, Shih-Han S; Heidenheim, Paul A; Gallo, Kerri; Jayakumar, Saumya; Lindsay, Robert M

    2011-01-01

    Access blood water flow rate (Qaw) can be measured during hemodialysis using an online effective ionic dialysance (EID) methodology. Fresenius employ this methodology in their 2008K dialysis machine. The machine computer converts Qaw to an access blood flow rate (Fresenius Qa) using a generic blood water constant (BWC). We wished to validate this BWC. 18 patients had Fresenius Qa measurements using the EID and these were compared with a 'gold standard' ultrasound dilution methodology (Transonic Qa). Qa values were also obtained by removing the BWC from Fresenius Qa values to obtain the Qaw and recorrecting it with individualized patient factors using hematocrit and total protein values (HctTp Qa). The measurements were repeated after 1 h. There were no significant differences between Fresenius and Transonic, nor between HctTp and Transonic Qa values (p > 0.17). There were strong correlations between both sets of values (r > 0.856; p Fresenius Qa pairs (r = 0.573; p > 0.07). It was surmised that the BWC was not valid post-dialysis. The generic BWC is comparable to individualized blood water correction factors when Qa measures are made early in dialysis and prior to ultrafiltration treatment. Copyright © 2011 S. Karger AG, Basel.

  6. Measurement of absolute bone blood flow by positron emission tomography

    Energy Technology Data Exchange (ETDEWEB)

    Nahmias, C.; Cockshott, W.P.; Garnett, E.S.; Belbeck, L.W.

    1986-03-01

    A method of measuring bone blood flow has been developed using /sup 18/F sodium fluoride and positron emission tomography. The blood flow levels are in line with those obtained experimentally from microsphere embolisation. This investigative method could be applied to elucidate a number of clinical questions involving bone perfusion.

  7. Noninvasive measurement of an index of renal blood flow

    International Nuclear Information System (INIS)

    Powers, T.A.; Rees, R.S.; Bowen, R.D.

    1983-01-01

    A new technique for the noninvasive measurement of an index of renal blood flow is described. The method utilizes ultrasound determined renal volume and radionuclide assessment of the mean transit time of a pertechnetate bolus through the kidneys. From this information a value for flow is calculated according to compartmental analysis principles. There is good correlation between renal blood flow estimated by this technique and that determined by microsphere injection

  8. Comparison of blood serum selenium concentrations from elderly population living in Sao Paulo city and literature data

    International Nuclear Information System (INIS)

    Saiki, Mitiko; Alves, Edson R.; Vasconcellos, Marina B.A.; Sumita, Nairo M.; Jaluul, Omar; Jacob Filho, Wilson

    2005-01-01

    Selenium is an essential nutrient of fundamental importance to human biology. This element is a component of the enzyme glutathione peroxidase that avoids the formation of free radicals protecting the organism against the oxidative damage. The Se concentrations in serum vary from one part of the world to another and this fact has been satisfactorily explained as a consequence of different Se intakes of the population. The main objective of this paper was the determination of serum Se concentrations in healthy elderly population included in a program for 'Successful Ageing' of the Hospital das Clinicas, Sao Paulo University Medical School. The blood samples were collected after a 12 h fast from 32 subjects aged 60 to 87 years. The blood was centrifuged after completely clotted and 4.0 mL of serum were freeze.dried for Se determination using neutron activation analysis. The serum samples and Se standard were irradiated for 16 h under a thermal neutron flux of de 5 x 10 12 n cm - '2 s -1 at the IEA-R1 nuclear reactor. Se was determined by measuring the gamma activity of 75 Se using an HGe detector coupled to a gamma ray spectrometer. The mean value of (0.92±0.07) μmol L -1 was obtained for serum Se concentration. This value is within the data used as reference values in clinical laboratories and those published in literature. Results obtained for certified reference materials NIST 1566b Oyster Tissue and NIST 1577b Bovine Liver showed good precision and agreed with the certified values. The relative standard deviation of the results was lower than 4.8 % and relative error lower than 0.97 %. Detection limit value obtained for serum Se determination was 0.003 μmol L-1. (author)

  9. Glucose Pump Test can be Used to Measure Blood Flow Rate of ...

    African Journals Online (AJOL)

    2018-02-07

    Feb 7, 2018 ... In 93 chronic hemodialysis patients with native AV fistula, blood flow rates were measured by Doppler US .... Arterial blood pressure from nonvascular access arm was measured by aneroid sphygmomanometer. The patients did not .... to detect differences in treatments across multiple test attempts. P < 0.05 ...

  10. The concentration of copper, zinc and molybdenum in serum and red blood cells of Filipinos

    International Nuclear Information System (INIS)

    Cruz, B. de la; Lansangan, L.M.; Asprer, G.A.; Paradero, R.R.; Acuna, T.T.

    1975-01-01

    Eighty-two samples of serum and red blood cells from 32 normal subjects and 50 patients with hypertension, old myocardial infarct and diabetes mellitus were analyzed by neutron activation analysis for copper, zinc and molybdenum. The mean value of copper in the normal serum (0.56 μg/g) was found to be lower than the reported mean values of 1.13 μg/g and 1.15 μg/g for foreign subjects. The mean value of copper in the normal red blood cells (0.55 μg/g) was also found to be lower than the reported values of 0.92 μg/g and 0.95 μg/g among foreigners. The mean concentration of copper in the serum of patients with hypertension and old myocardial infarct (1.02+-0.25 μg/g) and diabetes mellitus (1.06+-0.02 μg/g) were higher than the normal value of 0.56+-0.15 μg/g. The mean concentration of zinc in the serum of patients with hypertension and old myocardial infarct (0.74+-0.38 μg/g) and in diabetes mellitus (0.61+-0.33 μg/g) were lower than the normal value of 1.25+-0.58 μg/g. The level of copper in the red blood cells of patients with hypertension and old myocardial infarct (0.99+-0.62 μg/g) and diabetes mellitus (0.75+-0.39 μg/g) were found to be higher than the normal value of (0.55+-0.41) μg/g). The mean concentration of molybdenum in the red blood cells of patients with hypertension and old myocardial infarct (1.16+-0.73 μg/g) and diabetes mellitus (1.55+-0.91 μg/g) were higher than the normal level of 0.73+-0.43 μg/g. The results are discussed

  11. Optical measurement of blood flow in exercising skeletal muscle: a pilot study

    Science.gov (United States)

    Wang, Detian; Baker, Wesley B.; Parthasarathy, Ashwin B.; Zhu, Liguo; Li, Zeren; Yodh, Arjun G.

    2017-07-01

    Blood flow monitoring during rhythm exercising is very important for sports medicine and muscle dieases. Diffuse correlation spectroscopy(DCS) is a relative new invasive way to monitor blood flow but suffering from muscle fiber motion. In this study we focus on how to remove exercise driven artifacts and obtain accurate estimates of the increase in blood flow from exercise. Using a novel fast software correlator, we measured blood flow in forearm flexor muscles of N=2 healthy adults during handgrip exercise, at a sampling rate of 20 Hz. Combining the blood flow and acceleration data, we resolved the motion artifact in the DCS signal induced by muscle fiber motion, and isolated the blood flow component of the signal from the motion artifact. The results show that muscle fiber motion strongly affects the DCS signal, and if not accounted for, will result in an overestimate of blood flow more than 1000%. Our measurements indicate rapid dilation of arterioles following exercise onset, which enabled blood flow to increase to a plateau of 200% in 10s. The blood flow also rapidly recovered to baseline following exercise in 10s. Finally, preliminary results on the dependence of blood flow from exercise intensity changes will be discussed.

  12. Aortic blood pressure measured via EIT: investigation of different measurement settings.

    Science.gov (United States)

    Braun, Fabian; Proença, Martin; Rapin, Michael; Lemay, Mathieu; Adler, Andy; Grychtol, Bartłomiej; Solà, Josep; Thiran, Jean-Philippe

    2015-06-01

    Electrical impedance tomography (EIT) allows the measurement of intra-thoracic impedance changes related to cardiovascular activity. As a safe and low-cost imaging modality, EIT is an appealing candidate for non-invasive and continuous haemodynamic monitoring. EIT has recently been shown to allow the assessment of aortic blood pressure via the estimation of the aortic pulse arrival time (PAT). However, finding the aortic signal within EIT image sequences is a challenging task: the signal has a small amplitude and is difficult to locate due to the small size of the aorta and the inherent low spatial resolution of EIT. In order to most reliably detect the aortic signal, our objective was to understand the effect of EIT measurement settings (electrode belt placement, reconstruction algorithm). This paper investigates the influence of three transversal belt placements and two commonly-used difference reconstruction algorithms (Gauss-Newton and GREIT) on the measurement of aortic signals in view of aortic blood pressure estimation via EIT. A magnetic resonance imaging based three-dimensional finite element model of the haemodynamic bio-impedance properties of the human thorax was created. Two simulation experiments were performed with the aim to (1) evaluate the timing error in aortic PAT estimation and (2) quantify the strength of the aortic signal in each pixel of the EIT image sequences. Both experiments reveal better performance for images reconstructed with Gauss-Newton (with a noise figure of 0.5 or above) and a belt placement at the height of the heart or higher. According to the noise-free scenarios simulated, the uncertainty in the analysis of the aortic EIT signal is expected to induce blood pressure errors of at least ± 1.4 mmHg.

  13. Aortic blood pressure measured via EIT: investigation of different measurement settings

    International Nuclear Information System (INIS)

    Braun, Fabian; Proença, Martin; Rapin, Michael; Lemay, Mathieu; Solà, Josep; Adler, Andy; Grychtol, Bartłomiej; Thiran, Jean-Philippe

    2015-01-01

    Electrical impedance tomography (EIT) allows the measurement of intra-thoracic impedance changes related to cardiovascular activity. As a safe and low-cost imaging modality, EIT is an appealing candidate for non-invasive and continuous haemodynamic monitoring. EIT has recently been shown to allow the assessment of aortic blood pressure via the estimation of the aortic pulse arrival time (PAT). However, finding the aortic signal within EIT image sequences is a challenging task: the signal has a small amplitude and is difficult to locate due to the small size of the aorta and the inherent low spatial resolution of EIT. In order to most reliably detect the aortic signal, our objective was to understand the effect of EIT measurement settings (electrode belt placement, reconstruction algorithm). This paper investigates the influence of three transversal belt placements and two commonly-used difference reconstruction algorithms (Gauss–Newton and GREIT) on the measurement of aortic signals in view of aortic blood pressure estimation via EIT. A magnetic resonance imaging based three-dimensional finite element model of the haemodynamic bio-impedance properties of the human thorax was created. Two simulation experiments were performed with the aim to (1) evaluate the timing error in aortic PAT estimation and (2) quantify the strength of the aortic signal in each pixel of the EIT image sequences. Both experiments reveal better performance for images reconstructed with Gauss–Newton (with a noise figure of 0.5 or above) and a belt placement at the height of the heart or higher. According to the noise-free scenarios simulated, the uncertainty in the analysis of the aortic EIT signal is expected to induce blood pressure errors of at least ± 1.4 mmHg. (paper)

  14. The feasibility of measuring renal blood flow using transesophageal echocardiography in patients undergoing cardiac surgery.

    Science.gov (United States)

    Yang, Ping-Liang; Wong, David T; Dai, Shuang-Bo; Song, Hai-Bo; Ye, Ling; Liu, Jin; Liu, Bin

    2009-05-01

    There is no reliable method to monitor renal blood flow intraoperatively. In this study, we evaluated the feasibility and reproducibility of left renal blood flow measurements using transesophageal echocardiography during cardiac surgery. In this prospective noninterventional study, left renal blood flow was measured with transesophageal echocardiography during three time points (pre-, intra-, and postcardiopulmonary bypass) in 60 patients undergoing cardiac surgery. Sonograms from 6 subjects were interpreted by 2 blinded independent assessors at the time of acquisition and 6 mo later. Interobserver and intraobserver reproducibility were quantified by calculating variability and intraclass correlation coefficients. Patients with Doppler angles of >30 degrees (20 of 60 subjects) were eliminated from renal blood flow measurements. Left renal blood flow was successfully measured and analyzed in 36 of 60 (60%) subjects. Both interobserver and intraobserver variability were renal blood flow measurements were good to excellent (intraclass correlation coefficients 0.604-0.999). Left renal arterial luminal diameter for the pre, intra, and postcardiopulmonary bypass phases, ranged from 3.8 to 4.1 mm, renal arterial velocity from 25 to 35 cm/s, and left renal blood flow from 192 to 299 mL/min. In patients undergoing cardiac surgery, it was feasible in 60% of the subjects to measure left renal blood flow using intraoperative transesophageal echocardiography. The interobserver and intraobserver reproducibility of renal blood flow measurements was good to excellent.

  15. Relationship among visual field, blood flow, and neural structure measurements in glaucoma.

    Science.gov (United States)

    Hwang, John C; Konduru, Ranjith; Zhang, Xinbo; Tan, Ou; Francis, Brian A; Varma, Rohit; Sehi, Mitra; Greenfield, David S; Sadda, Srinivas R; Huang, David

    2012-05-17

    To determine the relationship among visual field, neural structural, and blood flow measurements in glaucoma. Case-control study. Forty-seven eyes of 42 patients with perimetric glaucoma were age-matched with 27 normal eyes of 27 patients. All patients underwent Doppler Fourier-domain optical coherence tomography to measure retinal blood flow and standard glaucoma evaluation with visual field testing and quantitative structural imaging. Linear regression analysis was performed to analyze the relationship among visual field, blood flow, and structure, after all variables were converted to logarithmic decibel scale. Retinal blood flow was reduced in glaucoma eyes compared to normal eyes (P flow and structural loss of rim area and retinal nerve fiber layer (RNFL). There was no correlation or paradoxical correlation between blood flow and structure. Multivariate regression analysis revealed that reduced blood flow and structural loss are independent predictors of visual field loss. Each dB decrease in blood flow was associated with at least 1.62 dB loss in mean deviation (P ≤ 0.001), whereas each dB decrease in rim area and RNFL was associated with 1.15 dB and 2.56 dB loss in mean deviation, respectively (P ≤ 0.03). There is a close link between reduced retinal blood flow and visual field loss in glaucoma that is largely independent of structural loss. Further studies are needed to elucidate the causes of the vascular dysfunction and potential avenues for therapeutic intervention. Blood flow measurement may be useful as an independent assessment of glaucoma severity.

  16. Association of lead concentration in colostrum, maternal and cord blood with newborn weight in polluted vs. non-polluted areas of Iran

    Directory of Open Access Journals (Sweden)

    Golmohammadi T.

    2007-10-01

    Full Text Available Background: Lead poisoning has proven to be one of the most important environmental health problems among developing countries with both direct and indirect effects on human life. Lead is known to cross the blood-brain barrier and placenta, and accumulates in soft and hard tissues. Lead can be excreted in urine, stool, milk, sweat, nails and saliva. During pregnancy and lactation, lead is released from bones into the blood along with Ca2+. The toxic effects of lead on various human tissues have been studied extensively, but few studies have addressed its impact on fetal development during pregnancy. Blood levels of lead are higher in people living in lead-polluted regions. It has been reported that Tehran (central and southern parts is the most problematic city in terms of lead poisoning.Methods: From 86 sets of mothers and newborns in a non-polluted area of rural Rasht, Iran, we examined specimens of maternal blood, cord blood and colostrum (86×3=258 and specimens from 85 sets of mothers and newborns in a polluted area of Tehran, Iran (85×3=255 for lead levels using atomic absorption spectrophotometry (AAS and analyzed the results by t-test, SPSS, and linear regression.Results: The mean blood lead concentrations of mothers, cord blood of newborns and colostrum were 7.6±4.1, 5.9±3 and 4.2±2.5 μg/dl, respectively, in the non-polluted area and 9.1±8.4, 6.5±5.2 and 5.8±5.5 μg/dl, respectively, in the polluted area. The mean weights of the newborns in non-polluted and polluted areas were 3.2±0.5 kg and 3.2±4.5 kg, respectively.Conclusions: Our data revealed an association between mean concentrations in blood lead of mothers and newborns and between mean concentrations of colostrum lead and newborn blood lead in both areas (p=0.01. There was no association between mean blood lead concentration of mothers with the weight of their newborns (p=0.89.

  17. Artificial neural networks to evaluate the boron concentration decreasing profile in Blood-BPA samples of BNCT patients

    Energy Technology Data Exchange (ETDEWEB)

    Garcia-Reiriz, Alejandro, E-mail: garciareiriz@gmail.com [Department of Analytical Chemistry, Faculty of Biochemical and Pharmaceutical Sciences, National University of Rosario, Rosario Institute of Chemistry (IQUIR-CONICET), Suipacha 531, Rosario S2002LRK (Argentina); Magallanes, Jorge [Comision Nacional de Energia Atomica, Av. Gral. Paz 1499, San Martin, B1650KNA, Buenos Aires (Argentina); Zupan, Jure [National Institute of Chemistry, Hajdrihova 19, SLO-1000 Ljubljana, Eslovenia (Slovenia); Liberman, Sara [Comision Nacional de Energia Atomica, Av. Gral. Paz 1499, San Martin, B1650KNA, Buenos Aires (Argentina)

    2011-12-15

    For the prediction of decay concentration profiles of the p-boronophenylalanine (BPA) in blood during BNCT treatment, a method is suggested based on Kohonen neural networks. The results of a model trained with the concentration profiles from the literature are described. The prediction of the model was validated by the leave-one-out method. Its robustness shows that it is mostly independent on small variations. The ability to fit retrospective experimental data shows an uncertainty lower than the two compartment model used previously. - Highlights: Black-Right-Pointing-Pointer We predicted decaying concentration profiles of BPA in blood during BNCT therapy. Black-Right-Pointing-Pointer Is suggested a method based on Kohonen neural networks. Black-Right-Pointing-Pointer The results show that it is very robust and mostly independent of small variations. Black-Right-Pointing-Pointer It has a better ability to fit retrospective experimental data. Black-Right-Pointing-Pointer The model could be progressively improved by adding new data to the training matrix.

  18. Artificial neural networks to evaluate the boron concentration decreasing profile in Blood-BPA samples of BNCT patients

    International Nuclear Information System (INIS)

    García-Reiriz, Alejandro; Magallanes, Jorge; Zupan, Jure; Líberman, Sara

    2011-01-01

    For the prediction of decay concentration profiles of the p-boronophenylalanine (BPA) in blood during BNCT treatment, a method is suggested based on Kohonen neural networks. The results of a model trained with the concentration profiles from the literature are described. The prediction of the model was validated by the leave-one-out method. Its robustness shows that it is mostly independent on small variations. The ability to fit retrospective experimental data shows an uncertainty lower than the two compartment model used previously. - Highlights: ► We predicted decaying concentration profiles of BPA in blood during BNCT therapy. ► Is suggested a method based on Kohonen neural networks. ► The results show that it is very robust and mostly independent of small variations. ► It has a better ability to fit retrospective experimental data. ► The model could be progressively improved by adding new data to the training matrix.

  19. Hybrid PIV-PTV technique for measuring blood flow in rat mesenteric vessels.

    Science.gov (United States)

    Ha, Hojin; Nam, Kweon-Ho; Lee, Sang Joon

    2012-11-01

    The micro-particle tracking velocimetry (μ-PTV) technique is used to obtain the velocity fields of blood flow in the microvasculature under in vivo conditions because it can provide the blood velocity distribution in microvessels with high spatial resolution. The in vivo μ-PTV technique usually requires a few to tens of seconds to obtain a whole velocity profile across the vessel diameter because of the limited number density of tracer particles under in vivo conditions. Thus, the μ-PTV technique alone is limited in measuring unsteady blood flows that fluctuate irregularly due to the heart beating and muscle movement in surrounding tissues. In this study, a new hybrid PIV-PTV technique was established by combining PTV and particle image velocimetry (PIV) techniques to resolve the drawbacks of the μ-PTV method in measuring blood flow in microvessels under in vivo conditions. Images of red blood cells (RBCs) and fluorescent particles in rat mesenteric vessels were obtained simultaneously. Temporal variations of the centerline blood velocity were monitored using a fast Fourier transform-based cross-correlation PIV method. The fluorescence particle images were analyzed using the μ-PTV technique to extract the spatial distribution of the velocity vectors. Data from the μ-PTV and PIV methods were combined to obtain a better estimate of the velocity profile in actual blood flow. This technique will be useful in investigating hemodynamics in microcirculation by measuring unsteady irregular blood flows more accurately. Copyright © 2012 Elsevier Inc. All rights reserved.

  20. Effect of Postural Change on Plasma Insulin Concentration in Normal Volunteer

    Energy Technology Data Exchange (ETDEWEB)

    Sung, Ho Kyung; Koh, Joo Whan; Joo, Jong Koo; Kim, Jin Yong; Lee, Jang Kyu [Korea Atomic Research Institute, Seoul (Korea, Republic of)

    1974-03-15

    The concentrations of some blood constituents are known to be influenced by the postural change. The blood glucose and insulin concentrations were measured, first, in the supine, and then (30 minutes later) in the erect positions under the fasting state. The effects of a duretic, furose-mide, were also studied under the same condition for 5 consecutive days. The materials were 5 healthy volunteers aging 20-29 years old with out any diabetic past, or family histories. The blood glucose was measured by the Nelson's method, and plasma insulin by the radioimmunoassay method. Following are the results; 1) The plasma insulin concentration in the erect position is slightly higher than in the supine position, however, the increase is statistically insignificant because of the notable individual variations in the values of the supine position. 2) Four out of 5 cases show the increase of about 80% of plasma insulin in the erect position, which is statistically significant if analyzed on the basis of frequency distribution. 3) The blood glucose concentration showed no postural changes. 4) The increase of the plasma insulin concentration in the erect position seems to the result of limited extra vasation of insulin in the lower extremities.

  1. Measurement of average radon gas concentration at workplaces

    International Nuclear Information System (INIS)

    Kavasi, N.; Somlai, J.; Kovacs, T.; Gorjanacz, Z.; Nemeth, Cs.; Szabo, T.; Varhegyi, A.; Hakl, J.

    2003-01-01

    In this paper results of measurement of average radon gas concentration at workplaces (the schools and kindergartens and the ventilated workplaces) are presented. t can be stated that the one month long measurements means very high variation (as it is obvious in the cases of the hospital cave and the uranium tailing pond). Consequently, in workplaces where the expectable changes of radon concentration considerable with the seasons should be measure for 12 months long. If it is not possible, the chosen six months period should contain summer and winter months as well. The average radon concentration during working hours can be differ considerable from the average of the whole time in the cases of frequent opening the doors and windows or using artificial ventilation. (authors)

  2. Comparative analysis of concentrations of lead, cadmium and mercury in cord blood, maternal blood, and breast milk, as well as persistent chlorinated hydrocarbons in maternal milk samples from Germany and Iran

    International Nuclear Information System (INIS)

    Javanmardi, F.

    2001-01-01

    The concentration of the heavy metals lead, cadmium and mercury in cord blood, maternal blood and breast milk has been studied. Lead and cadmium were analyzed by atomic absorption spectrometry. Mercury was determined using the flow-injection hydride technique. According to the concentrations of heavy metals and chlorinated hydrocarbons we ascertained for the region of Rendsburg, the toxic risk for infants relative to the consumption of contaminated maternal milk can be viewed as very slight. (orig.) [de

  3. Dramatic effect on Selenium concentration in blood serum due to the difference between the Hungarian and Indian dietary habits

    International Nuclear Information System (INIS)

    Szuecs, Z.; Lahiri, S.; Andrasi, D.; Kovacs, B.

    2012-01-01

    Complete text of publication follows. The importance of Selenium as trace element in animals, as well as in humans is well known. The deficiency of Selenium was observed in case of several heavy or fatal clinical events such as high infant mortality, premature, malformations and even prostate cancer. Hungary is in the top of their worldwide statistic with parallel of the low concentration of Selenium in soil as well as in food. The direct correlation can explain in Venezuela, where the prostate cancer is 'unknown disease'. The concentration of Selenium in India is higher than the worldwide level. Under the scientific bilateral cooperation 'Speciation dependent studies on physicochemical behavior of some elements in trace scale in natural and synthetic system' the Selenium was determined in human blood serum from the group of Hungarian and group of Indian patients. The samples were given in same time from each group. The main goal of the study was explain the effect of the traditional dietary habit for the level of Selenium. Therefore the samples were taken from the visiting scientist just arrived to the host institute as well as from the host scientists too. After 2 weeks stay the sampling was repeated, when the guest scientists eat the same food as the host scientists. The measurements were done in Thermo-2 ICP-MS from blood-serum separated by centrifuge. The results are summarized in Table 1. Dramatic effect was found for the level of Selenium in blood serum. As it was expected the Hungarian samples showed low concentration of Selenium in starting of the visit, as well as the high concentration was found in Indian sample, comparing to the Hungarian sample. After two weeks the Hungarian sample showed much higher concentration, however it was still less, than in Indian sample. Similar effect was found during the visit the Indian scientists in Hungary, however their Selenium concentration decreased not so spectacular due to the Selenium 'store' in body. The general

  4. Use of a blood gas analyzer and a laboratory autoanalyzer in routine practice to measure electrolytes in intensive care unit patients

    Directory of Open Access Journals (Sweden)

    Budak Yasemin U

    2012-08-01

    Full Text Available Abstract Background Electrolyte values are measured in most critically ill intensive care unit (ICU patients using both an arterial blood gas analyzer (ABG and a central laboratory auto-analyzer (AA. The aim of the present study was to investigate whether electrolyte levels assessed using an ABG and an AA were equivalent; data on sodium and potassium ion concentrations were examined. Methods We retrospectively studied patients hospitalized in the ICU between July and August 2011. Of 1,105 test samples, we identified 84 instances of simultaneous sampling of arterial and venous blood, where both Na+ and K+ levels were measured using a pHOx Stat Profile Plus L blood gas analyzer (Nova Biomedical, Waltham MA, USA and a Roche Modular P autoanalyzer (Roche Diagnostics, Mannheim, Germany. Statistical measures employed to compare the data included Spearman's correlation coefficients, paired Student’s t-tests, Deming regression analysis, and Bland-Altman plots. Results The mean sodium concentration was 138.1 mmol/L (SD 10.2 mmol/L using the ABG and 143.0 mmol/L (SD 10.5 using the AA (p + and Na+, with biases of 0.150-0.352 and −0.97-10.05 respectively; the associated correlation coefficients were 0.88 and 0.90. Conclusions We conclude that the ABG and AA do not yield equivalent Na+ and K+ data. Concordance between ABG and AA should be established prior to introduction of new ABG systems.

  5. A novel approach to office blood pressure measurement: 30-minute office blood pressure vs daytime ambulatory blood pressure

    NARCIS (Netherlands)

    Wel, M.C. van der; Buunk, I.E.; Weel, C. van; Thien, Th.; Bakx, J.C.

    2011-01-01

    PURPOSE: Current office blood pressure measurement (OBPM) is often not executed according to guidelines and cannot prevent the white-coat effect. Serial, automated, oscillometric OBPM has the potential to overcome both these problems. We therefore developed a 30-minute OBPM method that we compared

  6. Comparison of ambulatory blood pressure monitoring and office blood pressure measurements in obese children and adolescents.

    Science.gov (United States)

    Renda, Rahime

    2018-04-01

    Obesity in adults has been related to hypertension and abnormal nocturnal dipping of blood pressure, which are associated with poor cardiovascular and renal outcomes. Here, we aimed to resolve the relationship between the degree of obesity, the severity of hypertension and dipping status on ambulatory blood pressure in obese children. A total 72 patients with primary obesity aged 7 to 18 years (mean: 13.48 ± 3.25) were selected. Patients were divided into three groups based on body mass index (BMİ) Z-score. Diagnosis and staging of ambulatory hypertension based on 24-h blood pressure measurements, obtained from ambulatory blood pressure monitoring. Based on our ambulatory blood pressure data, 35 patients (48.6%) had hypertension, 7 (20%) had ambulatory prehypertension, 21 (60%) had hypertension, and 7 patients (20%) had severe ambulatory hypertension. There was a significant relationship between severity of hypertension and the degree of obesity (p lood pressure results and loads were similar between groups. Diastolic and mean arterial blood pressure levels during the night, diastolic blood pressure loads, and heart rate during the day were significantly higher in Group 3 (p lood pressure at night, mean arterial pressure at night, diastolic blood pressure loads and heart rate at day. Increase in BMI Z-score does not a significant impact on daytime blood pressure and nocturnal dipping status.

  7. Poor Reliability of Wrist Blood Pressure Self-Measurement at Home: A Population-Based Study.

    Science.gov (United States)

    Casiglia, Edoardo; Tikhonoff, Valérie; Albertini, Federica; Palatini, Paolo

    2016-10-01

    The reliability of blood pressure measurement with wrist devices, which has not previously been assessed under real-life circumstances in general population, is dependent on correct positioning of the wrist device at heart level. We determined whether an error was present when blood pressure was self-measured at the wrist in 721 unselected subjects from the general population. After training, blood pressure was measured in the office and self-measured at home with an upper-arm device (the UA-767 Plus) and a wrist device (the UB-542, not provided with a position sensor). The upper-arm-wrist blood pressure difference detected in the office was used as the reference measurement. The discrepancy between office and home differences was the home measurement error. In the office, systolic blood pressure was 2.5% lower at wrist than at arm (P=0.002), whereas at home, systolic and diastolic blood pressures were higher at wrist than at arm (+5.6% and +5.4%, respectively; Pblood pressure values likely because of a poor memory and rendition of the instructions, leading to the wrong position of the wrist. © 2016 American Heart Association, Inc.

  8. Concentrations of ions and metals in blood of amateur and elite runners using NAA

    International Nuclear Information System (INIS)

    Kovacs, L.; Zamboni, C.B.; Nunes, L.A.S.; Lourenco, T.F.; Macedo, D.V.

    2013-01-01

    Intense physical training is known to be associated with increased mineral losses through sweating (during the exercise) and also through urine (after the exercise). Nowadays physical training is recognized for adapting or damaging the muscles, depending on the intensity and duration of the effort, provoking detectable metabolic alterations in blood, mainly in the content of some ions. In this study Br, Ca, Cl, K, Mg, Na and S levels were investigated in blood of Brazilian athletes that were submitted to constant physical exercise, at Laboratorio de Bioquimica do Exercicio (LABEX/UNICAMP) using Neutron Activation Analyses technique (NAA). The blood samples were collected from male amateurs and elite athletes, ranging from 18 to 36 years old. The blood samples were irradiated in the nuclear reactor (IEA-R1, 3-4.5 MW, pool type) at IPEN/Sao Paulo-Brazil. The concentrations data were compared with the control group (subjects of same gender and age but not involved with physical activities). These data can be useful for evaluating the performance of endurance athletes during the period of competition preparation as well as to propose new evaluation of protocols not yet reported. (author)

  9. Effects of Zinc Supplementation on the Anthropometric Measurements, Lipid Profiles and Fasting Blood Glucose in the Healthy Obese Adults

    Directory of Open Access Journals (Sweden)

    Sepide Mahluji

    2013-02-01

    Full Text Available Purpose: The aim of this study was to assess the effects of zinc supplementation on anthropometric measures, improving lipid profile biomarkers, and fasting blood glucose level in obese people. Methods: This randomized, double- blind clinical trial was carried out on 60 obese participants in the 18-45 age range for one month. The participants were randomly divided into the intervention group, who received 30 mg/d zinc gluconate, and the placebo group who received 30mg/d starch. Anthropometric measurements (body mass index (BMI, weight and waist circumference were recorded before and at the end of study. Lipid profile biomarkers and fasting blood glucose were determined using enzymatic procedure. Analysis of Covariance (ANCOVA test was run to compare the post-treatment values of the two groups, and t-test was conducted to compare within group changes. Results: Serum zinc concentration was increased significantly in intervention group (p=0.024. BMI and body weight was significantly decreased (p=0.030 and p=0.020, respectively. Lipid profile biomarkers and fating blood glucose did not change significantly but triglyceride level was significantly decreased (p=0.006 in the intervention group. Conclusion: The obtained results indicate that zinc supplementation improves BMI, body weight, and triglyceride concentration without considerable effects on lipid profile and glucose level. Zinc can be suggested as a suitable supplementation therapy for obese people, but more studies are needed to verify the results.

  10. A novel wearable device for continuous, non-invasion blood pressure measurement.

    Science.gov (United States)

    Xin, Qin; Wu, Jianping

    2017-08-01

    In this paper, we have developed a wearable cuffless device for daily blood pressure (BP) measurement. We incorporated the light based sensor and other hard wares in a small volume for BP detection. With optimized algorithm, the real-time BP reading could be achieved, the data could be presented in the screen and be transmitted by internet of things (IoT) for history data comparison and multi-terminal viewing. Thus, further analysis provides the probability for diet or sports suggestion and alarm. We have measured BP from more than 60 subjects, compare to traditional mercury blood pressure meter, no obvious error in both systolic blood pressure (SBP) and diastolic blood pressure (DBP) are detected. Such device can be used for continues non-invasion BP detection, and further data docking and health analysis could be achieved. Copyright © 2017. Published by Elsevier Ltd.

  11. Uteroplacental blood flow measured by placental scintigraphy during epidural anaesthesia for caesarean section

    Energy Technology Data Exchange (ETDEWEB)

    Skjoeldebrand, A.; Eklund, J.; Johansson, H.; Lunell, N.-O.; Nylund, L.; Sarby, B.; Thornstroem, S. (Departments of Anaesthesiology, Obstetrics and Gynaecology and Medical Physics, Karolinska Institute at Huddinge University Hospital, Stockholm (Sweden))

    1990-01-01

    The uteroplacental blood flow was measured before and during epidural anaesthesia for caesarean section in 11 woman. The blood flow was measured with dynamic placental scintigraphy. After an i.v. injection of indium-113m chloride, the gamma radiation over the placenta was recorded with a computer-linked scintillation camera. The uteroplacental blood flow could be calculated from the isotope accumulation curve. The anaesthesia was performed with bupivacaine plain 0.5%, 18-22 ml and a preload of a balanced electrolyte solution 10 ml/kg b.w. was given. The placental blood flow decreased in eight patients and increased in three with a median change of -21%, not being statistically significant. No correlation between maternal blood pressure and placental blood flow was found. (author).

  12. Uteroplacental blood flow measured by placental scintigraphy during epidural anaesthesia for caesarean section

    International Nuclear Information System (INIS)

    Skjoeldebrand, A.; Eklund, J.; Johansson, H.; Lunell, N.-O.; Nylund, L.; Sarby, B.; Thornstroem, S.

    1990-01-01

    The uteroplacental blood flow was measured before and during epidural anaesthesia for caesarean section in 11 woman. The blood flow was measured with dynamic placental scintigraphy. After an i.v. injection of indium-113m chloride, the gamma radiation over the placenta was recorded with a computer-linked scintillation camera. The uteroplacental blood flow could be calculated from the isotope accumulation curve. The anaesthesia was performed with bupivacaine plain 0.5%, 18-22 ml and a preload of a balanced electrolyte solution 10 ml/kg b.w. was given. The placental blood flow decreased in eight patients and increased in three with a median change of -21%, not being statistically significant. No correlation between maternal blood pressure and placental blood flow was found. (author)

  13. Certain Red Blood Cell Indices of Maternal and Umbilical Cord ...

    African Journals Online (AJOL)

    Uche

    Background: Umbilical cord blood analysis may give a clue to the state of health of both pregnant mothers and their neonates. However ... Keywords: Umbilical cord blood; maternal blood; haemoglobin concentration; packed cell volume; red cell indices. Received on .... The packed cell volume was measured using the.

  14. Association between Blood Mercury Level and Visceral Adiposity in Adults

    Directory of Open Access Journals (Sweden)

    Jong Suk Park

    2017-01-01

    Full Text Available BackgroundFew studies have examined the association between mercury exposure and obesity. The aim of this study is to investigate the association between blood mercury concentrations and indices of obesity in adults.MethodsA total of 200 healthy subjects, aged 30 to 64 years, who had no history of cardiovascular or malignant disease, were examined. Anthropometric and various biochemical profiles were measured. Visceral adipose tissue (VAT was measured using dual-energy X-ray absorptiometry (DXA.ResultsAll subjects were divided into three groups according to blood mercury concentrations. Compared with the subjects in the lowest tertile of mercury, those in the highest tertile were more likely to be male; were current alcohol drinkers and smokers; had a higher body mass index (BMI, waist circumference (WC, and VAT; had higher levels of blood pressure, fasting glucose, and insulin resistance; and consumed more fish. The blood mercury concentration was significantly associated with anthropometric parameters, showing relationships with BMI, WC, and VAT. After adjusting for multiple risk factors, the odds ratios (ORs for high mercury concentration was significantly higher in the highest VAT tertile than in the lowest VAT tertile (OR, 2.66; 95% confidence interval, 1.05 to 6.62; P<0.05.ConclusionThe blood mercury concentration was significantly associated with VAT in healthy adults. Further studies are warranted to confirm our findings.

  15. Measuring the level of agreement between a veterinary and a human point-of-care glucometer and a laboratory blood analyzer in Hispaniolan Amazon parrots (Amazona ventralis).

    Science.gov (United States)

    Acierno, Mark J; Schnellbacher, Rodney; Tully, Thomas N

    2012-12-01

    Although abnormalities in blood glucose concentrations in avian species are not as common as they are in mammals, the inability to provide point-of-care glucose measurement likely results in underreporting and missed treatment opportunities. A veterinary glucometer that uses different optimization codes for specific groups of animals has been produced. To obtain data for a psittacine bird-specific optimization code, as well as to calculate agreement between the veterinary glucometer, a standard human glucometer, and a laboratory analyzer, blood samples were obtained from 25 Hispaniolan Amazon parrots (Amazona ventralis) in a 2-phase study. In the initial phase, blood samples were obtained from 20 parrots twice at a 2-week interval. For each sample, the packed cell volume was determined, and the blood glucose concentration was measured by the veterinary glucometer. The rest of each sample was placed into a lithium heparin microtainer tube and centrifuged, and plasma was removed and frozen at -30 degrees C. Within 5 days, tubes were thawed, and blood glucose concentrations were measured with a laboratory analyzer. The data from both procedures were used to develop a psittacine bird-specific code. For the second phase of the study, the same procedure was repeated twice at a 2-week interval in 25 birds to determine agreement between the veterinary glucometer, a standard human glucometer, and a laboratory analyzer. Neither glucometer was in good agreement with the laboratory analyzer (veterinary glucometer bias, 9.0; level of agreement, -38.1 to 56.2; standard glucometer bias, 69.4; level of agreement -17.8 to 156.7). Based on these results, the use of handheld glucometers in the diagnostic testing of Hispaniolan Amazon parrots and other psittacine birds cannot be recommended.

  16. The order of draw of blood specimens into additive containing tubes not affect potassium and calcium measurements.

    Science.gov (United States)

    Majid, A; Heaney, D C; Padmanabhan, N; Spooner, R

    1996-12-01

    The effect of order of draw when taking blood into tubes containing additive was investigated in 47 medical inpatients; 12 of these patients acted as a control group. The samples were analysed in the order in which they were withdrawn. The results of potassium and calcium concentrations did not differ significantly between groups. Manufacturers recommend a specific order of draw when taking blood using vacuum based blood collection systems, which are routinely used in many hospitals. The results of this study, however, show that order of draw has no effect on calcium or potassium concentrations.

  17. Clinical, blood gas and biochemical profile of diarrheic dairy calves fed starter concentrate containing citrus pulp as a replacement for corn

    Directory of Open Access Journals (Sweden)

    Marcelo Cezar Soares

    Full Text Available ABSTRACT: The objective of this study was to evaluate clinical signs, gas analysis, and metabolic effects of diarrhea in milk-fed calves consuming starter feed containing citrus pulp (CP as a replacement for corn. Twenty-four newborn Holstein male calves were distributed into treatments according to starter composition: (1 0% CP, (2 32% CP, (3 64% CP, on dry matter basis. The calves were housed in individual hutches, with free access to water and concentrate, and received 4 L/d of milk replacer. After diarrhea diagnosis, evaluations of fecal score, score of clinical signs and measurement of physiological parameters were performed three times a day during 3-d. Blood samples were collected for electrolytes, blood gases, and plasma biochemical analysis. Starter feed composition had no negative effect (P>0.05 on fecal score, characteristics of diarrheic stools and on the aggravation of diarrhea clinical signs. Biochemical, blood gases and electrolytes changes, as a function of starter composition, did not resulted (P>0.05 in dehydration, acidosis, or other metabolic disturbance animals. Total lactate and D-lactate plasma concentrations were higher for calves on control and 64% CP, and L-lactate was highest for the 64% CP; however, calves showed no signs of metabolic acidosis. Thermal comfort indexes influenced clinical and physiological parameters (P<0.05. Citrus pulp may replace corn in starter composition without prejudice to intestinal health or metabolism of young diarrheic calves.

  18. Overview of revised measures to prevent malaria transmission by blood transfusion in France.

    Science.gov (United States)

    Garraud, O; Assal, A; Pelletier, B; Danic, B; Kerleguer, A; David, B; Joussemet, M; de Micco, P

    2008-10-01

    Plasmodial transmission by blood donation is rare in non-endemic countries, but a very serious complication of blood transfusion. The French national blood service (Etablissement Français du Sang and Centre de Transfusion sanguine des Armees) intended to revise the measures to strengthen blood safety with regard to Plasmodiae as transmissible pathogens. To limit the risk of transmission during infusion, serious additive measures have been taken for more than a decade in France, which is the European country with the highest rate of exposure to imported plasmodial infections or malaria. These measures were revised and strengthened after the occurrence of a lethal transfusion-transmitted infection in 2002, but did not prevent another occurrence in 2006. This report examines the weaknesses of the systems and aims at emphasizing the safety measures already taken and addresses issues to best respond to that risk.

  19. Quantitative blood flow measurements in the small animal cardiopulmonary system using digital subtraction angiography

    Energy Technology Data Exchange (ETDEWEB)

    Lin Mingde; Marshall, Craig T.; Qi, Yi; Johnston, Samuel M.; Badea, Cristian T.; Piantadosi, Claude A.; Johnson, G. Allan [Department of Radiology, Center for In Vivo Microscopy and Department of Biomedical Engineering, Duke University Medical Center, Box 3302, Durham, North Carolina 27710 (United States); Division of Pulmonary and Critical Care Medicine and Center for Hyperbaric Medicine and Environmental Physiology, Duke University Medical Center, Box 3823, Durham, North Carolina 27710 (United States); Department of Radiology, Center for In Vivo Microscopy, Duke University Medical Center, Box 3302, Durham, North Carolina 27710 (United States); Department of Radiology, Center for In Vivo Microscopy and Department of Biomedical Engineering, Duke University Medical Center, Box 3302, Durham, North Carolina 27710 (United States); Department of Radiology, Center for In Vivo Microscopy, Duke University Medical Center, Box 3302, Durham, North Carolina 27710 (United States); Division of Pulmonary and Critical Care Medicine and Center for Hyperbaric Medicine and Environmental Physiology, Duke University Medical Center, Box 3823, Durham, North Carolina 27710 (United States); Department of Radiology, Center for In Vivo Microscopy and Department of Biomedical Engineering, Duke University Medical Center, Box 3302, Durham, North Carolina 27710 (United States)

    2009-11-15

    Purpose: The use of preclinical rodent models of disease continues to grow because these models help elucidate pathogenic mechanisms and provide robust test beds for drug development. Among the major anatomic and physiologic indicators of disease progression and genetic or drug modification of responses are measurements of blood vessel caliber and flow. Moreover, cardiopulmonary blood flow is a critical indicator of gas exchange. Current methods of measuring cardiopulmonary blood flow suffer from some or all of the following limitations--they produce relative values, are limited to global measurements, do not provide vasculature visualization, are not able to measure acute changes, are invasive, or require euthanasia. Methods: In this study, high-spatial and high-temporal resolution x-ray digital subtraction angiography (DSA) was used to obtain vasculature visualization, quantitative blood flow in absolute metrics (ml/min instead of arbitrary units or velocity), and relative blood volume dynamics from discrete regions of interest on a pixel-by-pixel basis (100x100 {mu}m{sup 2}). Results: A series of calibrations linked the DSA flow measurements to standard physiological measurement using thermodilution and Fick's method for cardiac output (CO), which in eight anesthetized Fischer-344 rats was found to be 37.0{+-}5.1 ml/min. Phantom experiments were conducted to calibrate the radiographic density to vessel thickness, allowing a link of DSA cardiac output measurements to cardiopulmonary blood flow measurements in discrete regions of interest. The scaling factor linking relative DSA cardiac output measurements to the Fick's absolute measurements was found to be 18.90xCO{sub DSA}=CO{sub Fick}. Conclusions: This calibrated DSA approach allows repeated simultaneous visualization of vasculature and measurement of blood flow dynamics on a regional level in the living rat.

  20. Quantitative blood flow measurements in the small animal cardiopulmonary system using digital subtraction angiography

    International Nuclear Information System (INIS)

    Lin Mingde; Marshall, Craig T.; Qi, Yi; Johnston, Samuel M.; Badea, Cristian T.; Piantadosi, Claude A.; Johnson, G. Allan

    2009-01-01

    Purpose: The use of preclinical rodent models of disease continues to grow because these models help elucidate pathogenic mechanisms and provide robust test beds for drug development. Among the major anatomic and physiologic indicators of disease progression and genetic or drug modification of responses are measurements of blood vessel caliber and flow. Moreover, cardiopulmonary blood flow is a critical indicator of gas exchange. Current methods of measuring cardiopulmonary blood flow suffer from some or all of the following limitations--they produce relative values, are limited to global measurements, do not provide vasculature visualization, are not able to measure acute changes, are invasive, or require euthanasia. Methods: In this study, high-spatial and high-temporal resolution x-ray digital subtraction angiography (DSA) was used to obtain vasculature visualization, quantitative blood flow in absolute metrics (ml/min instead of arbitrary units or velocity), and relative blood volume dynamics from discrete regions of interest on a pixel-by-pixel basis (100x100 μm 2 ). Results: A series of calibrations linked the DSA flow measurements to standard physiological measurement using thermodilution and Fick's method for cardiac output (CO), which in eight anesthetized Fischer-344 rats was found to be 37.0±5.1 ml/min. Phantom experiments were conducted to calibrate the radiographic density to vessel thickness, allowing a link of DSA cardiac output measurements to cardiopulmonary blood flow measurements in discrete regions of interest. The scaling factor linking relative DSA cardiac output measurements to the Fick's absolute measurements was found to be 18.90xCO DSA =CO Fick . Conclusions: This calibrated DSA approach allows repeated simultaneous visualization of vasculature and measurement of blood flow dynamics on a regional level in the living rat.

  1. TXRF 'measurements' of concentration distribution below the detection limit

    International Nuclear Information System (INIS)

    Kubala-Kukus, A.; Banas, D.; Braziewicz, J.; Majewska, U.; Mrowczynski, S.; Pajek, M.

    2000-01-01

    We demonstrate that a shape of the concentration distribution of the element in a set of samples, as measured by the TXRF method, can be determined even for the concentrations below the detection limit (DL). This can be done, when the measurements reporting the concentration below DL level are included properly in the analysis of the results. The method developed for such correction is presented and discussed. It is demonstrated that this correction is particularly important when the studied concentrations are close to the DL level of the method, which is a common case for TXRF. In the paper a precision of the developed correction is discussed in details, by using the results of numerical simulations of experiments for different concentration distributions and number of performed measurements. It is demonstrated that the factor, which limits the accuracy of the correction, is the number of measurements, not the correction procedure itself. The applicability and importance of the developed correction is demonstrated for routine TXRF analysis of different types of samples of bio-medical interest. (author)

  2. Placental weight, birth measurements, and blood pressure at age 8 years.

    OpenAIRE

    Moore, V M; Miller, A G; Boulton, T J; Cockington, R A; Craig, I H; Magarey, A M; Robinson, J S

    1996-01-01

    OBJECTIVE: To examine relationships between blood pressure during childhood and both placental weight and body size at birth, in an Australian population. DESIGN: A follow up study of a birth cohort, undertaken when cohort members were aged 8 years. SETTING: Adelaide, South Australia. SUBJECTS: 830 children born in the Queen Victoria Hospital in Adelaide, South Australia, during 1975-6. MAIN OUTCOME MEASURES: Systolic and diastolic blood pressure measured when the children were aged 8 years. ...

  3. Postmortem concentrations of gamma-hydroxybutyrate (GHB) in peripheral blood and brain tissue - Differentiating between postmortem formation and antemortem intake

    DEFF Research Database (Denmark)

    Thomsen, Ragnar; Rasmussen, Brian Schou; Johansen, Sys Stybe

    2017-01-01

    to fermentation processes. The endogenous nature of GHB leads to difficulty in interpretation of concentrations, as the source of GHB is not obvious. Postmortem brain and blood samples were collected from 221 individuals at autopsy. Of these, 218 were not suspected of having ingested GHB, while GHB intake....../kg (median 15.3mg/kg) in blood and not-detected to 9.8mg/kg (median 4.8mg/kg) in brain tissue. For case A, where intoxication with GHB was deemed to be the sole cause of death, the concentrations were 199 and 166mg/kg in blood and brain, respectively. For case B, where intoxication with GHB...

  4. A new approach for the carbon monoxide (CO) exposure diagnosis: measurement of total CO in human blood versus carboxyhemoglobin (HbCO).

    Science.gov (United States)

    Varlet, Vincent; De Croutte, Emma Lagroy; Augsburger, Marc; Mangin, Patrice

    2013-07-01

    The aim of the study is to present the application of a headspace-gas chromatography-mass spectrometry (HS-GC-MS) method for the determination of the carbon monoxide (CO) blood concentration and to compare it with carboxyhemoglobin (HbCO) saturation. In postmortem cases, the HbCO measured by spectrophotometry frequently leads to inaccurate results due to inadequate samples or analyses. The true role of CO intoxication in the death of a person could be misclassified. The estimation of HbCO from HS-GC-MS CO measurements provides helpful information by determining the total CO levels (CO linked to hemoglobin (HbCO) and CO dissociated from hemoglobin). The CO concentrations were converted in HbCO saturation levels to define cutoff blood CO values. CO limits were defined as less than 1 μmol/mL for living persons, less than 1.5 μmol/mL for dead persons without CO exposure, and greater than 3 μmol/mL for dead persons with clear CO poisoning. © 2013 American Academy of Forensic Sciences.

  5. TK Modeler version 1.0, a Microsoft® Excel®-based modeling software for the prediction of diurnal blood/plasma concentration for toxicokinetic use.

    Science.gov (United States)

    McCoy, Alene T; Bartels, Michael J; Rick, David L; Saghir, Shakil A

    2012-07-01

    TK Modeler 1.0 is a Microsoft® Excel®-based pharmacokinetic (PK) modeling program created to aid in the design of toxicokinetic (TK) studies. TK Modeler 1.0 predicts the diurnal blood/plasma concentrations of a test material after single, multiple bolus or dietary dosing using known PK information. Fluctuations in blood/plasma concentrations based on test material kinetics are calculated using one- or two-compartment PK model equations and the principle of superposition. This information can be utilized for the determination of appropriate dosing regimens based on reaching a specific desired C(max), maintaining steady-state blood/plasma concentrations, or other exposure target. This program can also aid in the selection of sampling times for accurate calculation of AUC(24h) (diurnal area under the blood concentration time curve) using sparse-sampling methodologies (one, two or three samples). This paper describes the construction, use and validation of TK Modeler. TK Modeler accurately predicted blood/plasma concentrations of test materials and provided optimal sampling times for the calculation of AUC(24h) with improved accuracy using sparse-sampling methods. TK Modeler is therefore a validated, unique and simple modeling program that can aid in the design of toxicokinetic studies. Copyright © 2012 Elsevier Inc. All rights reserved.

  6. Patients blood serum ferritin concentrations changes associated with Caesium-137 incorporation

    International Nuclear Information System (INIS)

    Shishkyina, V.V.; Chebotar'ova, E.D.; Zamyatyin, S.S.; Vlasenko, O.O.

    1993-01-01

    The results of radioimmune study of ferritin and carcinoembryonic antigen in 60 persons: 35 those who took part in liquidation of the Chernobyl accident and incorporated 25.9-70.4 MBq of Cesium-137,25 residents of Rivno Region with 7.4-203.5 MBq of the radionuclide in the organism are reported. The increased concentration of ferritin and carcinoembryonic antigen in blood serum was noted to be determined more often in the residents of the areas polluted with Caesium-137 than in l iquidators . The tumor markers levels depended to some extent on bad habits (smoking, alcohol) and existing chronic diseases of the alimentary system

  7. Peripheral blood volume influenced by various external factors

    Energy Technology Data Exchange (ETDEWEB)

    Ittner, A; Scheibe, J; Stoll, W [Friedrich-Schiller-Universitaet, Jena (German Democratic Republic). Bereich Medizin

    1982-01-01

    The dependence of the peripheral blood volume upon various exogenous factors was studied in male sports students using /sup 113m/InCl. The results obtained revealed that whole-body exertions and local muscular activity produce an increase of the blood volume in the lower extremities associated with increased blood circulation. The passive measures applied caused also an increase of the blood volume, but not in all of the subjects examined. Isometric concentrations led to a highly significant reduction of the peripheral blood volume. The scintigraphic method for the visualization of the blood volume in peripheral regions of the body can be regarded as suitable for the study of hemodynamics and for the substantiation of the efficiency of measures promoting restoration.

  8. Method of measuring blood flow by radiation

    International Nuclear Information System (INIS)

    Gildenberg, P.L.

    1977-01-01

    A method of measuring relative blood flow through at least a part of the body using penetrating radiation comprises transmitting a plurality of rays at an initial angle or initial mean angle through a planar slice of the body to define a first set of rays, transmitting a plurality of further sets of rays at angles or mean angles different from each other and from the initial angle or initial mean angle through the same planar slice of the body to define by the intersection of all such rays a two-dimensional matrix of elements of the body in the slice, measuring for each ray emerging from the body a number of over the period of time at least equal to a pulse interval representing the momentary sum of the transmissions or absorptions of the element of the body intersected by the ray, determining from the momentary signals momentary signals a difference signal representing the maximum difference between the momentary signals for each ray over the period of time, deriving sets of discrete difference signals corresponding to the sets of rays, the difference signals being indicative of the transmission or absorption of blood flowing through each element of the body in the matrix, and calculating from the difference signals resultant signals representing the transmissions or absorptions due to blood flow in the elements of the matrix. These resultant signals may be visually depicted on a cathode ray tube display, as a digital print-out, or as a photograph. 30 claims, 8 figures

  9. Influence on Calculated Blood Pressure of Measurement Posture for the Development of Wearable Vital Sign Sensors

    Directory of Open Access Journals (Sweden)

    Shouhei Koyama

    2017-01-01

    Full Text Available We studied a wearable blood pressure sensor using a fiber Bragg grating (FBG sensor, which is a highly accurate strain sensor. This sensor is installed at the pulsation point of the human body to measure the pulse wave signal. A calibration curve is built that calculates the blood pressure by multivariate analysis using the pulse wave signal and a reference blood pressure measurement. However, if the measurement height of the FBG sensor is different from the reference measurement height, an error is included in the reference blood pressure. We verified the accuracy of the blood pressure calculation with respect to the measurement height difference and the posture of the subject. As the difference between the measurement height of the FBG sensor and the reference blood pressure measurement increased, the accuracy of the blood pressure calculation decreased. When the measurement height was identical and only posture was changed, good accuracy was achieved. In addition, when calibration curves were built using data measured in multiple postures, the blood pressure of each posture could be calculated from a single calibration curve. This will allow miniaturization of the necessary electronics of the sensor system, which is important for a wearable sensor.

  10. Plasma Vitamin E and Blood Selenium Concentrations in Norwegian Dairy Cows: Regional Differences and Relations to Feeding and Health

    Directory of Open Access Journals (Sweden)

    Østerås O

    2005-12-01

    Full Text Available Plasma α-tocopherol (vit E and blood selenium (Se concentrations in February were determined in samples from 314 dairy cows in Norway, selected to provide a representative subset of the Norwegian dairy cow population. Each sample was followed by a questionnaire with information about feeding of the cow at the time of sampling. The results were correlated to herd data and to calving and health data for each cow from the Norwegian Dairy Herd Recording System and the Norwegian Cattle Health Recording System. The mean concentrations were 6.9 μg vit E per ml plasma and 0.16 μg Se per g blood. Both levels were highest in mid lactation. Plasma vit E varied with the amount of silage fed to the cow, while blood Se varied with the amount of concentrates and mineral supplements, and with geographical region. No differences in vit E or Se levels were found between cows with recorded treatments for mastitis, parturient paresis or reproductive disorders in the lactation during or immediately prior to sampling, and those without such treatments. For ketosis, a small difference in blood Se was found between the groups with or without recorded treatments. It is concluded that winter-fed lactating cows in Norway had an adequate plasma level of vit E and a marginal-to-adequate level of Se.

  11. Plasma Vitamin E and Blood Selenium Concentrations in Norwegian Dairy Cows: Regional Differences and Relations to Feeding and Health

    Directory of Open Access Journals (Sweden)

    Sivertsen T

    2006-12-01

    Full Text Available Plasma α-tocopherol (vit E and blood selenium (Se concentrations in February were determined in samples from 314 dairy cows in Norway, selected to provide a representative subset of the Norwegian dairy cow population. Each sample was followed by a questionnaire with information about feeding of the cow at the time of sampling. The results were correlated to herd data and to calving and health data for each cow from the Norwegian Dairy Herd Recording System and the Norwegian Cattle Health Recording System. The mean concentrations were 6.9 μg vit E per ml plasma and 0.16 μg Se per g blood. Both levels were highest in mid lactation. Plasma vit E varied with the amount of silage fed to the cow, while blood Se varied with the amount of concentrates and mineral supplements, and with geographical region. No differences in vit E or Se levels were found between cows with recorded treatments for mastitis, parturient paresis or reproductive disorders in the lactation during or immediately prior to sampling, and those without such treatments. For ketosis, a small difference in blood Se was found between the groups with or without recorded treatments. It is concluded that winter-fed lactating cows in Norway had an adequate plasma level of vit E and a marginal-to-adequate level of Se.

  12. Development and validation of a sensitive UPLC-MS/MS method for the quantitation of [(13)C]sucrose in rat plasma, blood, and brain: Its application to the measurement of blood-brain barrier permeability.

    Science.gov (United States)

    Miah, Mohammad K; Bickel, Ulrich; Mehvar, Reza

    2016-03-15

    Accurate and reproducible measurement of blood-brain barrier (BBB) integrity is critical in the assessment of the pathophysiology of the central nervous system disorders and in monitoring therapeutic effects. The widely-used low molecular weight marker [(14)C]sucrose is non-specific in the absence of chromatographic separation. The purpose of this study was to develop and validate a sensitive and reproducible LC-MS/MS method for the analysis of stable isotope-modified [(13)C12]sucrose in brain, plasma, and blood to determine BBB permeability to sucrose. After addition of internal standard (IS, [(13)C6]sucrose), the marker and IS were recovered from diluted rat blood, plasma, and brain homogenate by protein precipitation using acetonitrile. The recovery of the marker and IS was almost quantitative (90-106%) for all three matrices. The recovered samples were directly injected into an isocratic UPLC system with a run time of 6 min. Mass spectrometry was conducted using multiple reaction monitoring in negative mode. The method was linear (r(2)≥0.99) in the concentration ranges tested for the diluted blood and plasma (10-1000 ng/mL) and brain homogenate (1-200 ng/mL). The lower limit of quantitation of the assay was 0.5 pg injected on column. The assay was validated (n=5) based on acceptable intra- and inter-run accuracy and precision values. The method was successfully used for the measurement of serial blood and plasma and terminal brain concentrations of [(13)C12]sucrose after a single intravenous dose (10 mg/kg) of the marker to rats. As expected, the apparent brain uptake clearance values of [(13)C12]sucrose were low in healthy rats. The method may be useful for determination of the BBB integrity in animal models. Copyright © 2016 Elsevier B.V. All rights reserved.

  13. Reflective measurement of water concentration using millimeter wave illumination

    Science.gov (United States)

    Sung, Shijun; Bennett, David; Taylor, Zachary; Bajwa, Neha; Tewari, Priyamvada; Maccabi, Ashkan; Culjat, Martin; Singh, Rahul; Grundfest, Warren

    2011-04-01

    THz and millimeter wave technology have shown the potential to become a valuable medical imaging tool because of its sensitivity to water and safe, non-ionizing photon energy. Using the high dielectric constant of water in these frequency bands, reflectionmode THz sensing systems can be employed to measure water content in a target with high sensitivity. This phenomenology may lead to the development of clinical systems to measure the hydration state of biological targets. Such measurements may be useful in fast and convenient diagnosis of conditions whose symptoms can be characterized by changes in water concentration such as skin burns, dehydration, or chemical exposure. To explore millimeter wave sensitivity to hydration, a reflectometry system is constructed to make water concentration measurements at 100 GHz, and the minimum detectable water concentration difference is measured. This system employs a 100 GHz Gunn diode source and Golay cell detector to perform point reflectivity measurements of a wetted polypropylene towel as it dries on a mass balance. A noise limited, minimum detectable concentration difference of less than 0.5% by mass can be detected in water concentrations ranging from 70% to 80%. This sensitivity is sufficient to detect hydration changes caused by many diseases and pathologies and may be useful in the future as a diagnostic tool for the assessment of burns and other surface pathologies.

  14. Optical sensor technology for a noninvasive medical blood diagnosis

    Science.gov (United States)

    Kraitl, Jens; Ewald, Hartmut; Gehring, Hartmut

    2007-02-01

    NIR-spectroscopy and Photoplethysmography (PPG) and is used for a measurement of blood components. The fact that the absorption-coefficients μ a and scattering-coefficients μ s for blood differ at difference wavelengths has been exploited and is used for calculation of the optical absorbability characteristics of human blood yielding information on blood components like hemoglobin and oxygen saturation. The measured PPG time signals and the ratio between the peak to peak pulse amplitudes are used for a measurement of these parameters. A newly developed PMD device has been introduced. The non-invasive in-vivo multi-spectral method is based on the radiation of monochromatic light, emitted by laser diodes, through an area of skin on the finger. Deferrals between the proportions of hemoglobin and plasma in the intravasal volume should be detected photo-electrically by signal-analytic evaluation of the signals. The computed nonlinear coefficients are used for the measurement and calculation of the relative hemoglobin concentration change. Results with this photometric method to measure changes in the hemoglobin concentration were demonstrated during measurements with a hemodynamic model and healthy subjects. The PMD is suitable for non-invasive continuous online monitoring of one or more biologic constituent values. The objective of this development is to reduce the dependence on measurement techniques which require that a sample of blood be withdrawn from the patient for in-vitro analysis. Any invasive method used on the patient to obtain blood is accompanied by problems of inconvenience, stress, and discomfort. The patient is also exposed to the normal risks of infection associated with such invasive methods.

  15. Whole-blood viscosity and the insulin-resistance syndrome.

    Science.gov (United States)

    Høieggen, A; Fossum, E; Moan, A; Enger, E; Kjeldsen, S E

    1998-02-01

    In a previous study we found that elevated blood viscosity was linked to the insulin resistance syndrome, and we proposed that high blood viscosity may increase insulin resistance. That study was based on calculated viscosity. To determine whether directly measured whole-blood viscosity was related to the insulin-resistance syndrome in the same way as calculated viscosity had been found to be. Healthy young men were examined with the hyperinsulinemic isoglycemic glucose clamp technique, and we related insulin sensitivity (glucose disposal rate) to other metabolic parameters and to blood viscosity. We established a technique for direct measurement of whole-blood viscosity. There were statistically significant negative correlations between glucose disposal rate and whole-blood viscosity at low and high shear rates (r = -0.41, P = 0.007 for both, n = 42). Whole-blood viscosity was correlated positively (n = 15) to serum triglyceride (r = 0.54, P = 0.04) and total cholesterol (r = 0.52, P = 0.05), and negatively with high-density lipoprotein cholesterol (r = -0.53, P = 0.04) concentrations. Insulin sensitivity index was correlated positively to high-density lipoprotein cholesterol (r = 0.54, P = 0.04) and negatively to serum triglyceride (r = -0.69, P = 0.005) and to total cholesterol (r = -0.81, P = 0.0003) concentrations. The present results demonstrate for the first time that there is a negative relationship between directly measured whole-blood viscosity and insulin sensitivity as a part of the insulin-resistance syndrome. Whole-blood viscosity contributes to the total peripheral resistance, and these results support the hypothesis that insulin resistance has a hemodynamic basis.

  16. Concentration measurements of biodiesel in engine oil and in diesel fuel

    International Nuclear Information System (INIS)

    Mäder, A; Eskiner, M; Burger, C; Rossner, M; Krahl, J; Ruck, W

    2012-01-01

    This work comprised a method for concentration measurements of biodiesel in engine oil as well as biodiesel in diesel fuel by a measurement of the permittivity of the mixture at a frequency range from 100 Hz to 20 kHz. For this purpose a special designed measurement cell with high sensitivity was designed. The results for the concentration measurements of biodiesel in the engine oil and diesel fuel shows linearity to the measurement cell signal for the concentration of biodiesel in the engine oil between 0.5% Vol. to 10% Vol. and for biodiesel in the diesel fuel between 0% Vol. to 100% Vol. The method to measure the concentration of biodiesel in the engine oil or the concentration of biodiesel in the diesel fuel is very accurate and low concentration of about 0.5% Vol. biodiesel in engine oil or in diesel fuel can be measured with high accuracy.

  17. Radioimmunological assay of alpha-fetoprotein concentrations in blood serum samples from women in the first half of gestation

    International Nuclear Information System (INIS)

    Chomanski, M.; Grzes, A.

    1977-01-01

    In 66 unpregnant women and in 199 pregnant subjects (in the first half of pregnancy) the alpha-fetoprotein (α-FP) concentrations were determined in peripheric blood-serum samples. The α-FP was determined using radioimmunoo-assay technique where the addition of I 125 labelled protein was preceded by 3 hours lasting preincubation period. The free protein was separated from the bound by means of precipitation with a mixture of 96% ethanol and 34.5% ammonium acetate in a ratio 77.5 : 22.5. The patients were grouped into 5 subgroups according to the gestational age. The mean values of α-FP concentration demonstrated a steady increase along with the advancement of gestation. It is suggested that the concentration of this protein in the blood-serum samples may serve as a valuable parameter for the study of gestation development and the state of the fetus. (author)

  18. Blood pressure measurements in the ankle are not equivalent to ...

    African Journals Online (AJOL)

    Background. Blood pressure (BP) is often measured on the ankle in the emergency department (ED), but this has never been shown to be an acceptable alternative to measurements performed on the arm. Objective. To establish whether the differences between arm and ankle non-invasive BP measurements were clinically ...

  19. The increase in the cardiodepressant activity and vasopressin concentration in the sella turcica venous blood during vagal afferents stimulation or after angiotensin II infusion

    International Nuclear Information System (INIS)

    Goraca, A.; Orlowska-Majdak, M.; Traczyk, W.Z.

    1996-01-01

    It has previously been demonstrated that the cardiodepressant activity is present in the bovine hypothalamic extract and in the fluid incubating the posterior pituitary lobe i n situ . The present study was an attempt to reveal if the cardiodepressant factor and vasopressin were simultaneously released from the pituitary into blood. The samples of venous blood flowing from the sella turcica and, for comparison, from the posterior paw were collected in anesthetized rats. Blood from the sella turcica was collected with a fine cannula inserted into the internal maxillary vein. The concentration of vasopressin in blood plasma was determined by radioimmunoassay and cardiodepressant activity-using a biological test on a spontaneously discharged pacemaker tissue of the right auricle of the right heart atrium. Stimulation of the central ends of the cut vagus nerves or intra-arterial infusion of angiotensin II simultaneously caused an increase in the cardiodepressant activity and vasopressin concentration in the sella turcica venous blood. The cardiodepressant activity and vasopressin concentration was also enhanced to some degree in blood outflowing from the posterior paw. Present results indicate that both vasopressin and the cardiodepressant factor are released into blood from the posterior pituitary lobe. (author). 37 refs, 4 figs

  20. Re-evaluation of blood mercury, lead and cadmium concentrations in the Inuit population of Nunavik (Québec): a cross-sectional study

    Science.gov (United States)

    Fontaine, Julie; Dewailly, Éric; Benedetti, Jean-Louis; Pereg, Daria; Ayotte, Pierre; Déry, Serge

    2008-01-01

    Background Arctic populations are exposed to mercury, lead and cadmium through their traditional diet. Studies have however shown that cadmium exposure is most often attributable to tobacco smoking. The aim of this study is to examine the trends in mercury, lead and cadmium exposure between 1992 and 2004 in the Inuit population of Nunavik (Northern Québec, Canada) using the data obtained from two broad scale health surveys, and to identify sources of exposure in 2004. Methods In 2004, 917 adults aged between 18 and 74 were recruited in the 14 communities of Nunavik to participate to a broad scale health survey. Blood samples were collected and analysed for metals by inductively coupled plasma mass spectrometry, and dietary and life-style characteristics were documented by questionnaires. Results were compared with data obtained in 1992, where 492 people were recruited for a similar survey in the same population. Results Mean blood concentration of mercury was 51.2 nmol/L, which represent a 32% decrease (p < 0.001) between 1992 and 2004. Mercury blood concentrations were mainly explained by age (partial r2 = 0.20; p < 0.0001), and the most important source of exposure to mercury was marine mammal meat consumption (partial r2 = 0.04; p < 0.0001). In 2004, mean blood concentration of lead was 0.19 μmol/L and showed a 55% decrease since 1992. No strong associations were observed with any dietary source, and lead concentrations were mainly explained by age (partial r2 = 0.20.; p < 0.001). Blood cadmium concentrations showed a 22% decrease (p < 0.001) between 1992 and 2004. Once stratified according to tobacco use, means varied between 5.3 nmol/L in never-smokers and 40.4 nmol/L in smokers. Blood cadmium concentrations were mainly associated with tobacco smoking (partial r2 = 0.56; p < 0.0001), while consumption of caribou liver and kidney remain a minor source of cadmium exposure among never-smokers. Conclusion Important decreases in mercury, lead and cadmium exposure