WorldWideScience

Sample records for blood biocompatibility assessment

  1. A novel microporous polyurethane blood conduit: biocompatibility assessment of the UTA arterial prosthesis by an organo-typic culture technique.

    Science.gov (United States)

    Sigot-Luizard, M F; Sigot, M; Guidoin, R; King, M; von Maltzahn, W W; Kowligi, R; Eberhart, R C

    1993-01-01

    An organotypic culture assay has been used to assess the biocompatibility and cytotoxicity of an arterial prosthesis developed at the University of Texas-Arlington (the UTA graft) from a structurally modified polyurethane (PU) elastomer (Tecoflex). The cell culture test was applied to the UTA graft after sterilization by ethylene oxide and by gamma radiation in two separate series. First, small specimens of the prosthesis were incubated for 7 days on a semisolid nutrient medium with their luminal surface in direct contact with endothelium explanted from the aorta of chick embryos. Second, the possibility of cytotoxic contaminants being leached from the polyurethane was assessed by immersing the biomaterial in the liquid culture medium for 5 days at 37 degrees C prior to conducting the organo-typic culture assay on a standard control surface. The structure of the UTA polyurethane prosthesis is porous, but the graft wall is impervious because it contains closed (i.e., noncommunicating) pores. In addition, four other vascular prostheses were included in the study for comparison. They were the Hydrophilic Mitrathane PU graft with a similar impervious, closed pore structure, an experimental Hydrophobic Mitrathane PU graft with a fibrous, open pore structure, and the commercial Impra and Reinforced Goretex expanded PTFE grafts. Following 7 days of cell culture, the biocompatibility and cytotoxicity of the various biomaterials were measured in terms of the area of migrating cells, the density of cells surrounding the explants, and the level of cell adhesion. Comparison of the results against control cultures demonstrated that the UTA graft, along with the other four prostheses, does not release cytotoxic extractables. Microscopic observations of its cultured surface indicated that the UTA graft promotes a high density of cell growth over a limited area, similar to the Hydrophilic Mitrathane graft. This level of biocompatibility is considered inferior to that of the two

  2. Cultures and co-cultures of human blood mononuclear cells and endothelial cells for the biocompatibility assessment of surface modified AISI 316L austenitic stainless steel.

    Science.gov (United States)

    Stio, Maria; Martinesi, Maria; Treves, Cristina; Borgioli, Francesca

    2016-12-01

    Samples of AISI 316L austenitic stainless steel were subjected either to grinding and polishing procedure, or to grinding and then low temperature glow-discharge nitriding treatment, or to grinding, nitriding and subsequently coating with collagen-I. Nitrided samples, even if only ground, show a higher corrosion resistance in PBS solution, in comparison with ground and polished AISI 316L. Biocompatibility was evaluated in vitro by incubating the samples with either peripheral blood mononuclear cells (PBMC) or human umbilical vein endothelial cells (HUVEC), tested separately or in co-culture. HUVEC-PBMC co-culture and co-incubation of HUVEC with PBMC culture medium, after the previous incubation of PBMC with metallic samples, allowed to determine whether the incubation of PBMC with the different samples might affect HUVEC behaviour. Many biological parameters were considered: cell proliferation, release of cytokines, matrix metalloproteinases (MMPs) and sICAM-1, gelatinolytic activity of MMPs, and ICAM-1 protein expression. Nitriding treatment, with or without collagen coating of the samples, is able to ameliorate some of the biological parameters taken into account. The obtained results point out that biocompatibility may be successfully tested in vitro, using cultures of normal human cells, as blood and endothelial cells, but more than one cell line should be used, separately or in co-culture, and different parameters should be determined, in particular those correlated with inflammatory phenomena.

  3. Assessment of the biocompatibility of mineral trioxide aggregate ...

    African Journals Online (AJOL)

    2015-02-11

    Feb 11, 2015 ... The biocompatibility of dental materials can be evaluated via in vitro ... with excellent adhesion to the dentine according to the manufacturer. ..... literature review – part II: Leakage and biocompatibility investigations. J Endod.

  4. Assessing biocompatibility of graphene oxide-based nanocarriers: A review.

    Science.gov (United States)

    Kiew, Siaw Fui; Kiew, Lik Voon; Lee, Hong Boon; Imae, Toyoko; Chung, Lip Yong

    2016-03-28

    Graphene oxide (GO)-based nanocarriers have been frequently studied due to their high drug loading capacity. However, the unsatisfactory biocompatibility of these GO-based nanocarriers hampers their use in clinical settings. This review discusses how each of the physicochemical characteristics (e.g., size, surface area, surface properties, number of layers and particulate states) and surface coatings on GO affect its in vitro and in vivo nanotoxicity. We provide an overview on the effect of GO properties on interactions with cells such as red blood cells, macrophages and cell lines, and experimental organisms including rodents, rabbits and Zebrafish, offering some guidelines for development of safe GO-based nanocarriers. We conclude the paper by outlining the challenges involving GO-based formulations and future perspectives of this research in the biomedical field.

  5. Detection of micro- and nano-sized biocompatible particles in the blood.

    Science.gov (United States)

    Gatti, A M; Montanari, S; Monari, E; Gambarelli, A; Capitani, F; Parisini, B

    2004-04-01

    The research deals with new scanning electron microscopic evaluations of the interface between blood and explanted temporary vena cava filters from patients affected by blood disorders. The biological tissues adherent to the filter and the small thrombi formed in vivo were detached from the metallic structure of the device, fixed, dehydrated and prepared for the histological and the electron microscopy. The analyses showed that both samples (thrombus and newly formed tissue) contained foreign, in some cases nano-sized, bodies. The chemistry of these particles was different and varied, and unusual compounds containing non-biocompatible elements like bismuth, lead, wolfram, tungsten were also detected. The interaction between these debris travelling in the blood stream and the blood itself leads to suspect that the formation of the thrombus can originate from these inorganic and inert foreign bodies that act as triggering agent of the blood coagulation.

  6. Biocompatibility assessment of a long-term wearable artificial pump-lung in sheep.

    Science.gov (United States)

    Zhou, Kang; Niu, Shuqiong; Bianchi, Giacomo; Wei, Xufeng; Garimella, Narayana; Griffith, Bartley P; Wu, Zhongjun J

    2013-08-01

    The purpose of this study was to assess the biocompatibility of a newly developed long-term wearable artificial pump-lung (APL) in a clinically relevant ovine animal model. The wearable APL device was implanted in five sheep through left thoracotomy. The device was connected between the right atrium and pulmonary artery and evaluated for 30 days. Three sheep were used as the sham control. Platelet activation was assessed by measuring platelet surface P-selectin (CD62P) expression with flow cytometry and plasma soluble P-selectin with an enzyme-linked immunosorbent assay. Thrombotic deposition on the device components and hollow fiber membranes were analyzed with digital imaging and scanning electron microscopy. Surface P-selectin of the APL and sham groups changed significantly over the study period, but without significant differences between the two groups. Soluble P-selectin for the two groups peaked in the first 24 h after the surgery. Soluble P-selectin of the APL group remained slightly elevated over the study period compared to the presurgical baseline value and was slightly higher compared to that of the sham group. Plasma free hemoglobin remained in the normal ranges in all the animals. In spite of the surgery-related alteration in laboratory tests and elevation of platelet activation status, the APL devices in all the animals functioned normally (oxygen transfer and blood pumping) during the 30-day study period. The device flow path and membrane surface were free of gross thrombus. Electron microscopy images showed only scattered thrombi on the fibers (membrane surface and weft). In summary, the APL exhibited excellent biocompatibility. Two forms of platelet activation, surgery-related and device-induced, in the animals implanted with the wearable APL were observed. The limited device-induced platelet activation did not cause gross thrombosis and impair the long-term device performance.

  7. Novel mussel-inspired Ti-6Al-4V surfaces with biocompatibility, blood ultra-drag reduction and superior durability.

    Science.gov (United States)

    Li, Qi; Tang, Fei; Wang, Chunze; Wang, Xiaohao

    2017-07-01

    In order to develop new Ti-based biomaterials with biocompatibility, blood ultra-drag reduction and superior durability, a novel fabrication combining simple electrochemical and chemical processes was proposed. After being modified by C14H19F13O3Si (FAS), a biocompatible TiO2-SiO2-polydopamine composite surface on Ti-6Al-4V substrate was obtained. The biocompatibility was evaluated using a series of in vitro test, revealing that compared with Ti-6Al-4V alloys, the surfaces exhibited a number of bio-advantages such as anti-platelet aggregation, anti-bovine serum albumin protein adsorption, a lower hemolysis rate (~0.7%) and non-cytotoxicity (the cell viability >88%). The test of human microvascular endothelial cells (HMEC) cultured on the specimens for 48h showed better cell proliferation of the surface. Moreover, we explored the blood dynamic characteristics of titanium alloy substrate biomaterial for the first time, with a focus on the effects of dopamine-reactant concentration on blood flow resistance. The results showed that, compared to titanium alloy material, the TiO2-SiO2 surface modified by 4mg·mL(-1) dopamine solution displayed the optimal blood drag reduction characteristics, reaching a 76% drag reduction. After a 2m (800 meshes, 3500Pa) sandpaper abrasion test, the surface still maintained a superior repellency of blood (contact angles>150°, sliding angles<10°). This practical method may expand the applications of biomedical implantation materials. Copyright © 2017 Elsevier B.V. All rights reserved.

  8. Hancornia speciosa latex for biomedical applications: physical and chemical properties, biocompatibility assessment and angiogenic activity.

    Science.gov (United States)

    Almeida, Luciane Madureira; Floriano, Juliana Ferreira; Ribeiro, Thuanne Pires; Magno, Lais Nogueira; da Mota, Lígia Souza Lima Silveira; Peixoto, Nei; Mrué, Fátima; Melo-Reis, Paulo; Lino Junior, Ruy de Souza; Graeff, Carlos Frederico de Oliveira; Gonçalves, Pablo José

    2014-09-01

    The latex obtained from Hancornia speciosa is used in folk medicine for treatment of several diseases, such as acne, warts, diabetes, gastritis and inflammation. In this work, we describe the biocompatibility assessment and angiogenic properties of H. speciosa latex and its potential application in medicine. The physical-chemical characterization was carried out following different methodologies (CHN elemental analyses; thermogravimetric analyses and Fourier transform infrared spectroscopy). The biocompatibility was evaluated through cytotoxicity and genotoxicity tests in fibroblast mouse cells and the angiogenic properties were evaluated using the chick chorioallantoic membrane (CAM) assay model. The physical-chemical results showed that the structure of Hancornia speciosa latex biomembrane is very similar to that of Hevea brasiliensis (commercially available product). Moreover, the cytotoxicity and genotoxicity assays showed that H. speciosa latex is biocompatible with life systems and can be a good biomaterial for medical applications. The CAM test showed the efficient ability of H. speciosa latex in neovascularization of tissues. The histological analysis was in accordance with the results obtained in the CAM assay. Our data indicate that the latex obtained from H. speciosa and eluted in water showed significant angiogenic activity without any cytotoxic or genotoxic effects on life systems. The same did not occur with H. speciosa latex stabilized with ammonia. Addition of ammonia does not have significant effects on the structure of biomembranes, but showed a smaller cell survival and a significant genotoxicity effect. This study contributes to the understanding of the potentialities of H. speciosa latex as a source of new phytomedicines.

  9. Nanocrystalline Diamond as a Coating for Joint Implants: Cytotoxicity and Biocompatibility Assessment

    Directory of Open Access Journals (Sweden)

    Margarida Amaral

    2008-01-01

    Full Text Available Nanocrystalline diamond (NCD coatings combine a very low surface roughness with the outstanding diamond properties, such as superlative hardness, low self-friction coefficient, high wear and corrosion resistance, and biotolerance, which are ideal features for applications in medicine (knee and hip replacement and surgical tools. The present work presents a comprehensive study of the cytotoxicity and biocompatibility of NCD films grown by hot-filament chemical vapour deposition (HFCVD technique, aiming such future applications. Cytotoxicity was evaluated in vitro by seeding human gingival fibroblasts on the NCD surface for 14 days, while specific biocompatibility was assessed on samples seeded with human bone marrow-derived osteoblasts during 21 days. The NCD coatings proved to be noncytotoxic in the preliminary human gingival fibroblast cell cultures, as denoted by a notable sequence of cell attachment, spreading, and proliferation events. In the specific biocompatibility assay envisaging bone tissue applications, NCD coatings induced human osteoblast proliferation and the stimulation of differentiation markers, compared to standard polystyrene tissue culture plates.

  10. Biocompatibility assessment of rice husk-derived biogenic silica nanoparticles for biomedical applications

    Energy Technology Data Exchange (ETDEWEB)

    Alshatwi, Ali A., E-mail: alshatwi@ksu.edu.sa; Athinarayanan, Jegan; Periasamy, Vaiyapuri Subbarayan

    2015-02-01

    Synthetic forms of silica have low biocompatibility, whereas biogenic forms have myriad beneficial effects in current toxicological applications. Among the various sources of biogenic silica, rice husk is considered a valuable agricultural biomass material and a cost-effective resource that can provide biogenic silica for biomedical applications. In the present study, highly pure biogenic silica nanoparticles (bSNPs) were successfully harvested from rice husks using acid digestion under pressurized conditions at 120 °C followed by a calcination process. The obtained bSNPs were subjected to phase identification analysis using X-ray diffraction, which revealed the amorphous nature of the bSNPs. The morphologies of the bSNPs were observed using transmission electron microscopy (TEM), which revealed spherical particles 10 to 30 nm in diameter. Furthermore, the biocompatibility of the bSNPs with human lung fibroblast cells (hLFCs) was investigated using a viability assay and assessing cellular morphological changes, intracellular ROS generation, mitochondrial transmembrane potential and oxidative stress-related gene expression. Our results revealed that the bSNPs did not have any significant incompatibility in these in vitro cell-based approaches. These preliminary findings suggest that bSNPs are biocompatible, could be the best alternative to synthetic forms of silica and are applicable to food additive and biomedical applications. - Highlights: • Simple, rapid and convenient process • Amorphous and spherical with 10–30 nm size SiO{sub 2} nanoparticles were fabricated. • Biogenic silica nanoparticles showed biocompatibility. • bSNPs are an alternative to synthetic forms of silica.

  11. Evaluation of the expansion of umbilical cord blood derived from CD133+ cells on biocompatible microwells

    Directory of Open Access Journals (Sweden)

    Mina Soufizomorrod

    2016-05-01

    Full Text Available Background: Hematopoietic stem cell transplantation (HSCT is a therapeutic approach for treatment of hematological malignancies and incompatibility of Bone marrow. Umbilical cord blood (UCB has known as an alternative for hematopoietic stem/progenitor cells (HPSC in allogeneic transplantation. The low volume of collected samples is the main hindrance in application of HPSC derived from umbilical cord blood. So, ex vivo expansion of HPSCs is the useful approach to overcome this restriction. The goal of using this system is to produce appropriate amount of hematopoietic stem cells, which have the ability of transplantation and long term haematopoiesis. Material & Methods: In current study CD133+ cells were isolated from cord blood (CB. Isolated cells were seeded on microwells. Then expanded cells proliferation rate and ability in colony formation were assessed and finally were compared with 2 Dimensional (2D culture systems. Results: Our findings demonstrated that CD133+ cells derived from UCB which were cultivated on microwells had significantly higher rate of proliferation in compared with routine cell culture systems. Conclusion: In Current study, it was shown that CD133+ cells’ proliferations which were seeded on PDMS microwells coated with collagen significantly increased. We hope that 3 dimensional (3D microenvironment which mimics the 3D structure of bone marrow can solve the problem of using UCB as an alternative source of bone marrow.

  12. Biocompatibility Assessment of Si-based Nano- and Micro-particles

    Science.gov (United States)

    Jaganathan, Hamsa; Godin, Biana

    2012-01-01

    Silicon is one of the most abundant chemical elements found on the Earth. Due to its unique chemical and physical properties, silicon based materials and their oxides (e.g. silica) have been used in several industries such as building and construction, electronics, food industry, consumer products and biomedical engineering/medicine. This review summarizes studies on effects of silicon and silica nano- and micro-particles on cells and organs following four main exposure routes, namely, intravenous, pulmonary, dermal and oral. Further, possible genotoxic effects of silica based nanoparticles are discussed. The review concludes with an outlook on improving and standardizing biocompatibility assessment for nano- and micro-particles. PMID:22634160

  13. The consequence of biologic graft processing on blood interface biocompatibility and mechanics.

    Science.gov (United States)

    Van de Walle, Aurore B; Uzarski, Joseph S; McFetridge, Peter S

    2015-09-01

    Processing ex vivo derived tissues to reduce immunogenicity is an effective approach to create biologically complex materials for vascular reconstruction. Due to the sensitivity of small diameter vascular grafts to occlusive events, the effect of graft processing on critical parameters for graft patency, such as peripheral cell adhesion and wall mechanics, requires detailed analysis. Isolated human umbilical vein sections were used as model allogenic vascular scaffolds that were processed with either: 1. sodium dodecyl sulfate (SDS), 2. ethanol/acetone (EtAc), or 3. glutaraldehyde (Glu). Changes in material mechanics were assessed via uniaxial tensile testing. Peripheral cell adhesion to the opaque grafting material was evaluated using an innovative flow chamber that allows direct observation of the blood-graft interface under physiological shear conditions. All treatments modified the grafts tensile strain and stiffness properties, with physiological modulus values decreasing from Glu 240±12 kPa to SDS 210±6 kPa and EtAc 140±3 kPa, Papplied to the umbilical vein scaffold were shown to modify structural mechanics and cell adhesion properties, with the EtAc treatment reducing thrombotic events relative to SDS treated samples. This approach allows time and cost effective prescreening of clinically relevant grafting materials to assess initial cell reactivity.

  14. Polysaccharide Fabrication Platforms and Biocompatibility Assessment as Candidate Wound Dressing Materials

    Directory of Open Access Journals (Sweden)

    Donald C. Aduba

    2017-01-01

    Full Text Available Wound dressings are critical for wound care because they provide a physical barrier between the injury site and outside environment, preventing further damage or infection. Wound dressings also manage and even encourage the wound healing process for proper recovery. Polysaccharide biopolymers are slowly becoming popular as modern wound dressings materials because they are naturally derived, highly abundant, inexpensive, absorbent, non-toxic and non-immunogenic. Polysaccharide biopolymers have also been processed into biomimetic platforms that offer a bioactive component in wound dressings that aid the healing process. This review primarily focuses on the fabrication and biocompatibility assessment of polysaccharide materials. Specifically, fabrication platforms such as electrospun fibers and hydrogels, their fabrication considerations and popular polysaccharides such as chitosan, alginate, and hyaluronic acid among emerging options such as arabinoxylan are discussed. A survey of biocompatibility and bioactive molecule release studies, leveraging polysaccharide’s naturally derived properties, is highlighted in the text, while challenges and future directions for wound dressing development using emerging fabrication techniques such as 3D bioprinting are outlined in the conclusion. This paper aims to encourage further investigation and open up new, disruptive avenues for polysaccharides in wound dressing material development.

  15. Resveratrol-Loaded Albumin Nanoparticles with Prolonged Blood Circulation and Improved Biocompatibility for Highly Effective Targeted Pancreatic Tumor Therapy

    Science.gov (United States)

    Geng, Tao; Zhao, Xia; Ma, Meng; Zhu, Gang; Yin, Ling

    2017-06-01

    Human serum albumin (HSA) is an intrinsic protein and important carrier that transports endogenous as well as exogenous substances across cell membranes. Herein, we have designed and prepared resveratrol (RV)-loaded HSA nanoparticles conjugating RGD (arginine-glycine-aspartate) via a polyethylene glycol (PEG) "bridge" (HRP-RGD NPs) for highly effective targeted pancreatic tumor therapy. HRP-RGD NPs possess an average size of 120 ± 2.6 nm with a narrow distribution, a homodisperse spherical shape, a RV encapsulation efficiency of 62.5 ± 4.21%, and a maximum RV release ratio of 58.4.2 ± 2.8% at pH 5.0 and 37 °C. In vitro biocompatibility of RV is improved after coating with HSA and PEG. Confocal fluorescence images show that HRP-RGD NPs have the highest cellular uptake ratio of 47.3 ± 4.6% compared to HRP NPs and HRP-RGD NPs with free RGD blocking, attributing to an RGD-mediated effect. A cell counting kit-8 (CCK-8) assay indicates that HRP-RGD NPs without RV (HP-RGD NPs) have nearly no cytotoxicity, but HRP-RGD NPs are significantly more cytotoxic to PANC-1 cells compared to free RV and HRP NPs in a concentration dependent manner, showing apoptotic morphology. Furthermore, with a formulated PEG and HSA coating, HRP-RGD NPs prolong the blood circulation of RV, increasing approximately 5.43-fold (t1/2). After intravenous injection into tumor-bearing mice, the content of HRP-RGD NPs in tumor tissue was proven to be approximately 3.01- and 8.1-fold higher than that of HRP NPs and free RV, respectively. Based on these results, HRP-RGD NPs were used in an in vivo anti-cancer study and demonstrated the best tumor growth suppression effect of all tested drugs with no relapse, high in vivo biocompatibility, and no significant systemic toxicity over 35 days treatment. These results demonstrate that HRP-RGD NPs with prolonged blood circulation and improved biocompatibility have high anti-cancer effects with promising future applications in cancer therapy.

  16. The Effect of Polymeric Nanoparticles on Biocompatibility of Carrier Red Blood Cells.

    Directory of Open Access Journals (Sweden)

    Daniel Pan

    Full Text Available Red blood cells (RBCs can be used for vascular delivery of encapsulated or surface-bound drugs and carriers. Coupling to RBC prolongs circulation of nanoparticles (NP, 200 nm spheres, a conventional model of polymeric drug delivery carrier enabling their transfer to the pulmonary vasculature without provoking overt RBC elimination. However, little is known about more subtle and potentially harmful effects of drugs and drug carriers on RBCs. Here we devised high-throughput in vitro assays to determine the sensitivity of loaded RBCs to osmotic stress and other damaging insults that they may encounter in vivo (e.g. mechanical, oxidative and complement insults. Sensitivity of these tests is inversely proportional to RBC concentration in suspension and our results suggest that mouse RBCs are more sensitive to damaging factors than human RBCs. Loading RBCs by NP at 1:50 ratio did not affect RBCs, while 10-50 fold higher NP load accentuated RBC damage by mechanical, osmotic and oxidative stress. This extensive loading of RBC by NP also leads to RBCs agglutination in buffer; however, addition of albumin diminished this effect. These results provide a template for analyses of the effects of diverse cargoes loaded on carrier RBCs and indicate that: i RBCs can tolerate carriage of NP at doses providing loading of millions of nanoparticles per microliter of blood; ii tests using protein-free buffers and mouse RBCs may overestimate adversity that may be encountered in humans.

  17. Application of finite element analysis for assessing biocompatibility of intra-arterial catheters and probes.

    Science.gov (United States)

    Bedingham, W; Neavin, T D

    1991-01-01

    A commercial finite element modeling program (FIDAP) was adapted to compute the fluid dynamics of laminar blood flow around an intra-arterial catheter and/or sensor probe. The model provided an accurate transient solution to the Navier-Stokes equations under pulsatile blood flow conditions. To simulate the compliance in the catheter tubing set, a second order convolution integral was incorporated into the boundary conditions. The saline drip rate and catheter compliance could be specified, and the bulk blood flow, blood pressure, and heart rate were varied to simulate specific patient conditions. Analysis of the transient solution was used to assess probable sites for thrombus activation and deposition. The transient velocity and pressure fields identified regions of separated flow and recirculation. The computed shear rates and stresses were used to predict hemolysis, platelet activation, and thrombus formation. Analysis of particle paths provided an estimate of residence times and thrombus deposition sites.

  18. Biocompatibility Assessment of Polyethylene Glycol-Poly L-Lysine-Poly Lactic-Co-Glycolic Acid Nanoparticles In Vitro and In Vivo.

    Science.gov (United States)

    Guo, Liting; Chen, Baoan; Liu, Ran; Xia, Guohua; Wang, Yonglu; Li, Xueming; Wei, Chen; Wang, Xuemei; Jiang, Hulin

    2015-05-01

    The present study was designed to evaluate the biocompatibility of nanoparticles polyethylene glycol (PEG)-poly L-lysine (PLL)-poly lactic-co-glycolic acid copolymer (PLGA) (PEG-PLL-PLGA) before clinical application. We applied some tests to assess the safety of PEG-PLL-PLGA nanoparticles (NPs). There was low cytotoxicity of PEG-PLL-PLGA NPs in vitro as detected by MTT assay. Cell apoptosis and intracellular accumulation of PEG-PLL-PLGA were determined by FCM assay. The apoptotic rate induced by nanoparticles and the fluorescence intensity of intracellular daunorubicin (DNR) demonstrated that DNR-PEG-PLL-PLGA could be taken up by the mouse fibroblast cells (L929 cells). Hemolysis test and micronucleus (MN) assay demonstrated that the nanoparticles have no obviously blood toxicity and genotoxicity. DNR-PEG-PLL-PLGA NPs were injected into mice through tail vein to calculate the median lethal dose (LD50), the results showed that they had a wide safe scale. Blood was taken by removing the eyeball of mice to study the influence of DNR-PEG-PLL-PLGA in hepatic and renal functions. The results revealed that there was no significant difference as compared with the control group. Interestingly, the pathologic changes of heart, liver, spleen, lung and kidney were observed in nanoparticles treated mice. Thus, this study demonstrates that PEG-PLL-PLGA NPs appear to be highly biocompatible and safe nanoparticles that can be suitable for further application in the treatment of tumor.

  19. In Vitro Models in BiocompatibilityAssessment for Biomedical-Grade Chitosan Derivatives in Wound Management

    Directory of Open Access Journals (Sweden)

    Lim Chin Keong

    2009-03-01

    Full Text Available One of the ultimate goals of wound healing research is to find effective healing techniques that utilize the regeneration of similar tissues. This involves the modification of various wound dressing biomaterials for proper wound management. The biopolymer chitosan (b-1,4-D-glucosamine has natural biocompatibility and biodegradability that render it suitable for wound management. By definition, a biocompatible biomaterial does not have toxic or injurious effects on biological systems. Chemical and physical modifications of chitosan influence its biocompatibility and biodegradability to an uncertain degree. Hence, the modified biomedical-grade of chitosan derivatives should be pre-examined in vitro in order to produce high-quality, biocompatible dressings. In vitro toxicity examinations are more favorable than those performed in vivo, as the results are more reproducible and predictive. In this paper, basic in vitro tools were used to evaluate cellular and molecular responses with regard to the biocompatibility of biomedical-grade chitosan. Three paramount experimental parameters of biocompatibility in vitro namely cytocompatibility, genotoxicity and skin pro-inflammatory cytokine expression, were generally reviewed for biomedical-grade chitosan as wound dressing.

  20. Assessment of the biocompatibility and stability of a gold nanoparticle collagen bioscaffold.

    Science.gov (United States)

    Grant, Sheila A; Spradling, Claire S; Grant, Daniel N; Fox, Derek B; Jimenez, Luis; Grant, David A; Rone, Rebecca J

    2014-02-01

    Collagen has been utilized as a scaffold for tissue engineering applications due to its many advantageous properties. However, collagen in its purified state is mechanically weak and prone to rapid degradation. To mitigate these effects, collagen can be crosslinked. Although enhanced mechanical properties and stability can be achieved by crosslinking, collagen can be rendered less biocompatible either due to changes in the overall microstructure or due to the cytotoxicity of the crosslinkers. We have investigated crosslinking collagen using gold nanoparticles (AuNPs) to enhance mechanical properties and resistance to degradation while also maintaining its natural microstructure and biocompatibility. Rat tail type I collagen was crosslinked with AuNPs using a zero-length crosslinker, 1-ethyl-3-(3-dimethylaminopropyl) carbodiimide (EDC). Several characterization studies were performed including electron microscopy, collagenase assays, ROS assays, and biocompatibility assays. The results demonstrated that AuNP-collagen scaffolds had increased resistance to degradation as compared to non-AuNP-collagen while still maintaining an open microstructure. Although the biocompatibility assays showed that the collagen and AuNP-collagen scaffolds are biocompatible, the AuNP-collagen demonstrated enhanced cellularity and glycoaminoglycans (GAG) production over the collagen scaffolds. Additionally, the Reactive Oxygen Species (ROS) assays indicated the ability of the AuNP-collagen to reduce oxidation. Overall, the AuNP-collagen scaffolds demonstrated enhanced biocompatibility and stability over non-AuNP scaffolds.

  1. Chemico-physical characterisation and in vivo biocompatibility assessment of DLC-coated coronary stents.

    Science.gov (United States)

    Castellino, Micaela; Stolojan, Vlad; Virga, Alessandro; Rovere, Massimo; Cabiale, Karine; Galloni, Marco R; Tagliaferro, Alberto

    2013-01-01

    The vast majority of stent thrombosis occurs in the acute and sub-acute phases and is more common in patients with acute coronary syndromes, due to the thrombotic milieu where stent struts are positioned. Stent thrombosis is likely due to incomplete tissue coverage of metallic stents as the contact between metallic stents and blood elements may lead to platelet adhesion and trigger vessel thrombosis. If a stent is covered after 7 days, the risk that it will be found uncovered at later stages is very low (<1%). In this article, we demonstrate that diamond-like carbon (DLC) coatings, deposited by physical vapour deposition, promote rapid endothelisation of coronary stent devices, with very low platelets activation, reducing thrombotic clots. We relate these behaviours to the surface and bulk material properties of the DLC films, subjected to a comprehensive chemico-physical characterisation using several techniques (X-ray photoelectron spectroscopy, atomic force microscopy, field-emission scanning electron microscope, transmission electron microscopy combined with electron energy loss spectroscopy, Raman and dispersive X-ray spectroscopy). In vivo studies, conducted on 24 pigs, have shown complete endothelisation after 7 days, with no fibrin mesh and with only rare monocytes scattered on the endothelial layer while 30 and 180 days tests have shown reduced inflammatory activation and a complete stabilisation of the vessel healing, with a minimal neointimal proliferation. The integral and permanent DLC film coating improves haemo- and bio-compatibility and leads to an excellent early vessel healing of the stent whilst the extremely thin strut thickness reduces the amount of late neointima and consequently the risk of late restenosis. These data should translate into a reduced acute and sub-acute stent thrombosis.

  2. Autophagy induction by silver nanowires: A new aspect in the biocompatibility assessment of nanocomposite thin films

    Energy Technology Data Exchange (ETDEWEB)

    Verma, Navin K. [Institute of Molecular Medicine, Trinity College Dublin (Ireland); Centre for Research on Adaptive Nanostructures and Nanodevices, Trinity College Dublin (Ireland); Conroy, Jennifer [Institute of Molecular Medicine, Trinity College Dublin (Ireland); Lyons, Philip E.; Coleman, Jonathan [Centre for Research on Adaptive Nanostructures and Nanodevices, Trinity College Dublin (Ireland); O' Sullivan, Mary P. [Institute of Molecular Medicine, Trinity College Dublin (Ireland); Kornfeld, Hardy [University of Massachusetts Medical School, Massachusetts (United States); Kelleher, Dermot [Institute of Molecular Medicine, Trinity College Dublin (Ireland); Volkov, Yuri, E-mail: yvolkov@tcd.ie [Institute of Molecular Medicine, Trinity College Dublin (Ireland); Centre for Research on Adaptive Nanostructures and Nanodevices, Trinity College Dublin (Ireland)

    2012-11-01

    Nanomaterials and their enabled products have increasingly been attracting global attention due to their unique physicochemical properties. Among these emerging products, silver nanowire (AgNW)-based thin films are being developed for their promising applications in next generation nanoelectronics and nanodevices. However, serious concerns remain about possible health and safety risks they may pose. Here, we employed a multi-modal systematic biocompatibility assessment of thin films incorporating AgNW. To represent the possible routes of nanomaterial entry during occupational or environmental exposure, we employed four different cell lines of epithelial, endothelial, gastric, and phagocytic origin. Utilizing a cell-based automated image acquisition and analysis procedure in combination with real-time impedance sensing, we observed a low level of cytotoxicity of AgNW, which was dependent on cell type, nanowire lengths, doses and incubation times. Similarly, no major cytotoxic effects were induced by AgNW-containing thin films, as detected by conventional cell viability and imaging assays. However, transmission electron microscopy and Western immunoblotting analysis revealed AgNW-induced autophasosome accumulation together with an upregulation of the autophagy marker protein LC3. Autophagy represents a crucial mechanism in maintaining cellular homeostasis, and our data for the first time demonstrate triggering of such mechanism by AgNW in human phagocytic cells. Finally, atomic force microscopy revealed significant changes in the topology of cells attaching and growing on these films as substrates. Our findings thus emphasize the necessity of comprehensive biohazard assessment of nanomaterials in modern applications and devices and a thorough analysis of risks associated with their possible contact with humans through occupational or environmental exposure. Highlights: ► Thin films containing nanomaterials are subject to increasing contact with humans. ► This

  3. Biocompatibility assessment of modified Portland cement in comparison with MTA® : In vivo and in vitro studies

    Directory of Open Access Journals (Sweden)

    I Khalil

    2012-01-01

    Full Text Available Aim: The aim of our study is to elaborate a new cement based on Portland cement (PC, Modified Portland Cement (MPC with modified chemical and physical properties that allow easier clinical manipulation and faster setting time than MTA® and then to evaluate its cytotoxicity in vitro and its biocompatibility in vivo in comparison with MTA® . Materials and Methods: Elaboration of MPC: Portland cement powder slenderly grinded to homogenize the particles, mixed with a radiopaque element and a setting time accelerator. A comparative in vitro study (MTS test of the toxic effect of MTA® and MPC with culture isolated from the calvaria of 18-day-old fetal Swiss OF1 mice are done. A comparative in vivo study of the biocompatibility of MTA® and MPC: Under general anaesthesia, three holes (2.5 mm were made in both the left and right femurs of six White New Zealand rabbits. In the first hole MPC is placed, in the second MTA® and the third one is left empty (negative control group. Three weeks after implantation, two rabbits are sacrificed, then two other rabbits over six weeks and the last two after twelve weeks. The neck of the femur is trimmed and prepared for undecalcified histological studies. Mann-Whitney test was used to analyze the results. Results: The cell viability test according to the morphological observations suggested the biocompatibility of the two biomaterials tested. The in vivo test showed similar biocompatibility between MTA® and MPC. Bone healing and minimal inflammatory response adjacent to MTA® and MPC implants were observed at all experimental periods (3, 6 and 12 weeks, suggesting that both materials are well tolerated. Conclusion: This pilot comparative study of MTA® and MPC showed no or very limited toxic effects of both cements in vitro and similar biocompatibility in vivo. However, additional in vivo and clinical studies should be done on MPC before it can be introduced in our clinical practice.

  4. Base-metal dental casting alloy biocompatibility assessment using a human-derived three-dimensional oral mucosal model.

    LENUS (Irish Health Repository)

    McGinley, E L

    2012-01-01

    Nickel-chromium (Ni-Cr) alloys used in fixed prosthodontics have been associated with type IV Ni-induced hypersensitivity. We hypothesised that the full-thickness human-derived oral mucosa model employed for biocompatibility testing of base-metal dental alloys would provide insights into the mechanisms of Ni-induced toxicity. Primary oral keratinocytes and gingival fibroblasts were seeded onto Alloderm™ and maintained until full thickness was achieved prior to Ni-Cr and cobalt-chromium (Co-Cr) alloy disc exposure (2-72 h). Biocompatibility assessment involved histological analyses with cell viability measurements, oxidative stress responses, inflammatory cytokine expression and cellular toxicity analyses. Inductively coupled plasma mass spectrometry analysis determined elemental ion release levels. We detected adverse morphology with significant reductions in cell viability, significant increases in oxidative stress, inflammatory cytokine expression and cellular toxicity for the Ni-Cr alloy-treated oral mucosal models compared with untreated oral mucosal models, and adverse effects were increased for the Ni-Cr alloy that leached the most Ni. Co-Cr demonstrated significantly enhanced biocompatibility compared with Ni-Cr alloy-treated oral mucosal models. The human-derived full-thickness oral mucosal model discriminated between dental alloys and provided insights into the mechanisms of Ni-induced toxicity, highlighting potential clinical relevance.

  5. In vitro biocompatibility assessment of Co-Cr-Mo dental cast alloy

    Directory of Open Access Journals (Sweden)

    Dimić Ivana

    2015-01-01

    Full Text Available Metallic materials, such as Co-Cr-Mo alloys, are exposed to aggressive conditions in the oral cavity which represents ideal environment for metallic ion release and biodegradation. The released metallic ions from dental materials can cause local and/or systemic adverse effects in the human body. Therefore, the dental materials are required to possess appropriate mechanical, physical, chemical and biological properties. The biocompatibility of metallic materials is very important for dental applications. Accordingly, the aim of this study was to examine metallic ion release and cytotoxicity of Co-30Cr-5Mo cast alloy as the initial phase of biocompatibility evaluation. Determination of human (MRC-5 and animal (L929 fibroblast cells viability was conducted using three in vitro test methods: colorimetric methyl-thiazol-tetrazolium (MTT test, dye exclusion test (DET and agar diffusion test (ADT. Furthermore, the cells morphology and growth were analyzed using scanning electron microscopy (SEM. The obtained results indicated that Co-30Cr-5Mo alloy did not release harmful elements in high concentrations that could cause detrimental effects on human and animal fibroblasts under the given experimental conditions. Moreover, the fibroblast cells showed good adhesion on the Co-30Cr-5Mo alloy surface. Therefore, it can be concluded that Co-30Cr-5Mo alloy is biocompatible material which can be safely used in dentistry. [Projekat Ministarstva nauke Republike Srbije, br. III 46010 i br. ON 174004

  6. Biocompatibility and biomineralization assessment of bioceramic-, epoxy-, and calcium hydroxide-based sealers.

    Science.gov (United States)

    Bueno, Carlos Roberto Emerenciano; Valentim, Diego; Marques, Vanessa Abreu Sanches; Gomes-Filho, João Eduardo; Cintra, Luciano Tavares Angelo; Jacinto, Rogério Castilho; Dezan-Junior, Eloi

    2016-06-14

    Obturation of the root canal system aims to fill empty spaces, promoting hermetic sealing and preventing bacterial activity in periapical tissues. This should provide optimal conditions for repair, stimulating the process of biomineralization. An endodontic sealer should be biocompatible once it is in direct contact with periapical tissues. The aim of this study was to evaluate the rat subcutaneous tissue response to implanted polyethylene tubes filled with Smartpaste Bio, Acroseal, and Sealapex and investigate mineralization ability of these endodontic sealers. Forty Wistar rats were assigned to the three sealers groups and control group, (n = 10 animals/group) and received subcutaneous implants containing the test sealers, and the control group were implanted with empty tubes. After days 7, 15, 30, and 60, animals were euthanized and polyethylene tubes were removed with the surrounding tissues. Inflammatory infiltrate and thickness of the fibrous capsule were histologically evaluated. Mineralization was analyzed by Von Kossa staining and polarized light. Data were tabulated and analyzed via Kruskal-Wallis and Dunn's test. All tested materials induced a moderate inflammatory reaction in the initial periods. Smartpaste Bio induced the mildest inflammatory reactions after day 15. No difference was observed among groups after days 30 or 60. Von Kossa-positive staining and birefringent structures observed under polarized light revealed a larger mineralization area in Sealapex-treated animals followed by Smartpaste Bio-treated animals. At the end of the experiment, all tested sealers were found to be biocompatible. All sealers induced biomineralization, except Acroseal, which induced a mild tissue reaction.

  7. Bare and protein-conjugated Fe3O4 ferromagnetic nanoparticles for utilization in magnetically assisted hemodialysis: biocompatibility with human blood cells

    Science.gov (United States)

    Stamopoulos, D.; Manios, E.; Gogola, V.; Benaki, D.; Bouziotis, P.; Niarchos, D.; Pissas, M.

    2008-12-01

    Magnetically assisted hemodialysis is a development of conventional hemodialysis and is based on the circulation of ferromagnetic nanoparticle-targeted binding substance conjugates (FN-TBS Cs) in the bloodstream of the patient and their eventual removal by means of a 'magnetic dialyzer'. Presented here is an in vitro investigation on the biocompatibility of bare Fe3O4 FNs and Fe3O4-bovine serum albumin Cs with blood cells, namely red blood cells (RBCs), white blood cells (WBCs) and platelets (Plts). Atomic force microscopy (AFM) and optical microscopy (OM) enabled the examination of blood cells at the nanometer and micrometer level, respectively. The observations made on FN- and C-maturated blood samples are contrasted to those obtained on FN- and C-free reference blood samples subjected to exactly the same maturation procedure. Qualitatively, both AFM and OM revealed no changes in the overall shape of RBCs, WBCs and Plts. Incidents where bare FNs or Cs were bound onto the surface of RBCs or internalized by WBCs were very rare. Detailed examination by means of OM proved that impaired coagulation of Plts is not initiated/promoted either by FNs or Cs. Quantitatively, the statistical analysis of the obtained AFM images from RBC surfaces clearly revealed that the mean surface roughness of RBCs maturated with bare FNs or Cs was identical to the one of reference RBCs.

  8. Nanotherapeutics in angiogenesis: synthesis and in vivo assessment of drug efficacy and biocompatibility in zebrafish embryos

    Directory of Open Access Journals (Sweden)

    Cheng J

    2011-09-01

    Full Text Available Jinping Cheng1*, Yan-Juan Gu2*, Yajun Wang3, Shuk Han Cheng1, Wing-Tak Wong21Department of Biology and Chemistry, The City University of Hong Kong, Kowloon, 2Department of Applied Biology and Chemical Technology, The Hong Kong Polytechnic University, Hung Hom, Kowloon, 3Department of Medicine, The University of Hong Kong, Pokfulam, Hong Kong, People's Republic of China *These authors contributed equally to this work Background: Carbon nanotubes have shown broad potential in biomedical applications, given their unique mechanical, optical, and chemical properties. In this pilot study, carbon nanotubes have been explored as multimodal drug delivery vectors that facilitate antiangiogenic therapy in zebrafish embryos. Methods: Three different agents, ie, an antiangiogenic binding site (cyclic arginine-glycine-aspartic acid, an antiangiogenic drug (thalidomide, and a tracking dye (rhodamine, were conjugated onto single-walled carbon nanotubes (SWCNT. The biodistribution, efficacy, and biocompatibility of these triple functionalized SWCNT were tested in mammalian cells and validated in transparent zebrafish embryos. Results: Accumulation of SWCNT-associated nanoconjugates in blastoderm cells facilitated drug delivery applications. Mammalian cell xenograft assays demonstrated that these antiangiogenic SWCNT nanoconjugates specifically inhibited ectopic angiogenesis in the engrafted zebrafish embryos. Conclusion: This study highlights the potential of using SWCNT for generating efficient nanotherapeutics. Keywords: carbon nanotubes, drug delivery, antiangiogenic therapy

  9. Biocompatibility assessment of spark plasma-sintered alumina-titanium cermets.

    Science.gov (United States)

    Guzman, Rodrigo; Fernandez-García, Elisa; Gutierrez-Gonzalez, Carlos F; Fernandez, Adolfo; Lopez-Lacomba, Jose Luis; Lopez-Esteban, Sonia

    2016-01-01

    Alumina-titanium materials (cermets) of enhanced mechanical properties have been lately developed. In this work, physical properties such as electrical conductivity and the crystalline phases in the bulk material are evaluated. As these new cermets manufactured by spark plasma sintering may have potential application for hard tissue replacements, their biocompatibility needs to be evaluated. Thus, this research aims to study the cytocompatibility of a novel alumina-titanium (25 vol. % Ti) cermet compared to its pure counterpart, the spark plasma sintered alumina. The influence of the particular surface properties (chemical composition, roughness and wettability) on the pre-osteoblastic cell response is also analyzed. The material electrical resistance revealed that this cermet may be machined to any shape by electroerosion. The investigated specimens had a slightly undulated topography, with a roughness pattern that had similar morphology in all orientations (isotropic roughness) and a sub-micrometric average roughness. Differences in skewness that implied valley-like structures in the cermet and predominance of peaks in alumina were found. The cermet presented a higher surface hydrophilicity than alumina. Any cytotoxicity risk associated with the new materials or with the innovative manufacturing methodology was rejected. Proliferation and early-differentiation stages of osteoblasts were statistically improved on the composite. Thus, our results suggest that this new multifunctional cermet could improve current alumina-based biomedical devices for applications such as hip joint replacements.

  10. Segmentation Method of Time-Lapse Microscopy Images with the Focus on Biocompatibility Assessment.

    Science.gov (United States)

    Soukup, Jindřich; Císař, Petr; Šroubek, Filip

    2016-06-01

    Biocompatibility testing of new materials is often performed in vitro by measuring the growth rate of mammalian cancer cells in time-lapse images acquired by phase contrast microscopes. The growth rate is measured by tracking cell coverage, which requires an accurate automatic segmentation method. However, cancer cells have irregular shapes that change over time, the mottled background pattern is partially visible through the cells and the images contain artifacts such as halos. We developed a novel algorithm for cell segmentation that copes with the mentioned challenges. It is based on temporal differences of consecutive images and a combination of thresholding, blurring, and morphological operations. We tested the algorithm on images of four cell types acquired by two different microscopes, evaluated the precision of segmentation against manual segmentation performed by a human operator, and finally provided comparison with other freely available methods. We propose a new, fully automated method for measuring the cell growth rate based on fitting a coverage curve with the Verhulst population model. The algorithm is fast and shows accuracy comparable with manual segmentation. Most notably it can correctly separate live from dead cells.

  11. Biocompatibility Assessment of PLCL-Sericin Copolymer Membranes Using Wharton’s Jelly Mesenchymal Stem Cells

    Directory of Open Access Journals (Sweden)

    Kewalin Inthanon

    2016-01-01

    Full Text Available Stem cells based tissue engineering requires biocompatible materials, which allow the cells to adhere, expand, and differentiate in a large scale. An ideal biomaterial for clinical application should be free from mammalian products which cause immune reactivities and pathogen infections. We invented a novel biodegradable poly(L-lactic-co-ε-caprolactone-sericin (PLCL-SC copolymer membrane which was fabricated by electrospinning. Membranes with concentrations of 2.5 or 5% (w/v SC exhibited qualified texture characteristics with a noncytotoxic release profile. The hydrophilic properties of the membranes were 35–40% higher than those of a standard PLCL and commercial polystyrene (PS. The improved characteristics of the membranes were due to an addition of new functional amide groups, C=O, N–H, and C–N, onto their surfaces. Degradation of the membranes was controllable, depending on the content proportion of SC. Results of thermogram indicated the superior stability and crystallinity of the membranes. These membranes enhanced human Wharton’s jelly mesenchymal stem cells (hWJMSC proliferation by increasing cyclin A and also promoted cell adhesion by upregulating focal adhesion kinase (FAK. On the membranes, hWJMSC differentiated into a neuronal lineage with the occurrence of nestin. These data suggest that PLCL-SC electrospun membrane represents some properties which will be useful for tissue engineering and medical applications.

  12. Thermal property and assessment of biocompatibility of poly(lactic-co-glycolic) acid/graphene nanocomposites

    Energy Technology Data Exchange (ETDEWEB)

    Adhikari, Ananta R., E-mail: aa8381@gmail.com [Texas Center for Superconductivity, University of Houston, Houston, Texas-77204 (United States); Rusakova, Irene; Chu, Wei-Kan [Texas Center for Superconductivity, University of Houston, Houston, Texas-77204 (United States); Department of Physics, University of Houston, Texas-77204 (United States); Haleh, Ardebili [Department of Mechanical Engineering, University of Houston, Texas, Texas-77204 (United States); Luisi, Jonathan; Panova, Neli I.; Laezza, Fernanda [Department of Pharmacology and Toxicology, University of Texas Medical Branch, Galveston, Texas-77555 (United States)

    2014-02-07

    Polymer-matrix nanocomposites based on Poly(lactic-co-glycolic) acid (PLGA) and Graphene platelets (GNPs) were studied. GNPs, nanomaterials with a 2D flat surface, were chosen with or without chemical modification in PLGA/GNP nanocomposites and their microstructure, thermal property, and their compatibility as scaffolds for cell growth were investigated. PLGA/GNP nanocomposites (0, 1, and 5 wt. % of GNPs) were prepared using a solution based technique. Transmission electron microscopy, X-ray diffraction, Differential scanning calorimeter, and Thermogravimetric analyzer were used to analyze morphology and thermal properties. This work demonstrated the role of GNPs flat surface to provide a favorable platform resulting in an enhanced PLGA crystallization. Functionalized GNPs suppress both the thermal stability and the crystallization of PLGA. Finally, to determine the potential usefulness of these scaffolds for biomedical applications, mammalian cells were cultured on various PLGA/GNP nanocomposites (0, 1, and 5 wt. % GNPs). 1 wt. % PLGA/GNP nanocomposites showed better biocompatibility for cell growth with/without graphenes functionalization compared to pure PLGA and 5 wt. % PLGA/GNP. The function of GNPs in PLGA/GNPs (1 wt. %) composites is to provide a stage for PLGA crystallization where cell growth is favored. These results provide strong evidence for a new class of materials that could be important for biomedical applications.

  13. Gold nanoparticles prepared by laser ablation in aqueous biocompatible solutions: assessment of safety and biological identity for nanomedicine applications

    Directory of Open Access Journals (Sweden)

    Correard F

    2014-11-01

    Full Text Available Florian Correard,1,2 Ksenia Maximova,3 Marie-Anne Estève,1,2 Claude Villard,1 Myriam Roy,4 Ahmed Al-Kattan,3 Marc Sentis,3 Marc Gingras,4 Andrei V Kabashin,3 Diane Braguer1,2 1Aix Marseille Université, INSERM, CR02 UMR_S911, Marseille, France; 2APHM, Hôpital Timone, Marseille, France; 3Aix Marseille Université, CNRS, LP3 UMR 7341, Marseille, France; 4Aix Marseille Université, CNRS, CINAM, UMR 7325 Marseille, France Abstract: Due to excellent biocompatibility, chemical stability, and promising optical properties, gold nanoparticles (Au-NPs are the focus of research and applications in nanomedicine. Au-NPs prepared by laser ablation in aqueous biocompatible solutions present an essentially novel object that is unique in avoiding any residual toxic contaminant. This paper is conceived as the next step in development of laser-ablated Au-NPs for future in vivo applications. The aim of the study was to assess the safety, uptake, and biological behavior of laser-synthesized Au-NPs prepared in water or polymer solutions in human cell lines. Our results showed that laser ablation allows the obtaining of stable and monodisperse Au-NPs in water, polyethylene glycol, and dextran solutions. The three types of Au-NPs were internalized in human cell lines, as shown by transmission electron microscopy. Biocompatibility and safety of Au-NPs were demonstrated by analyzing cell survival and cell morphology. Furthermore, incubation of the three Au-NPs in serum-containing culture medium modified their physicochemical characteristics, such as the size and the charge. The composition of the protein corona adsorbed on Au-NPs was investigated by mass spectrometry. Regarding composition of complement C3 proteins and apolipoproteins, Au-NPs prepared in dextran solution appeared as a promising drug carrier. Altogether, our results revealed the safety of laser-ablated Au-NPs in human cell lines and support their use for theranostic applications. Keywords: protein

  14. Kinetics of elimination and distribution in blood and liver of biocompatible ferrofluids based on Fe{sub 3}O{sub 4} nanoparticles: An EPR and XRF study

    Energy Technology Data Exchange (ETDEWEB)

    Gamarra, L.F. [Instituto de Ensino e Pesquisa, Hospital Israelita Albert Einstein, Sao Paulo 05651-901 (Brazil); Instituto de Fisica, Universidade de Sao Paulo, Sao Paulo 05315-970 (Brazil)], E-mail: lgamarra@if.usp.br; Pontuschka, W.M. [Instituto de Fisica, Universidade de Sao Paulo, Sao Paulo 05315-970 (Brazil); Amaro, E. [Instituto de Ensino e Pesquisa, Hospital Israelita Albert Einstein, Sao Paulo 05651-901 (Brazil); Instituto de Radiologia, Faculdade de Medicina, Universidade de Sao Paulo, Sao Paulo 05403-001 (Brazil); Costa-Filho, A.J. [Instituto de Fisica de Sao Carlos, Universidade de Sao Paulo, Sao Carlos 13560-970 (Brazil); Brito, G.E.S. [Instituto de Fisica, Universidade de Sao Paulo, Sao Paulo 05315-970 (Brazil); Vieira, E.D. [Instituto de Fisica de Sao Carlos, Universidade de Sao Paulo, Sao Carlos 13560-970 (Brazil); Carneiro, S.M. [Laboratorio de Biologia Celular, Instituto Butantan, Sao Paulo 05503-900 (Brazil); Escriba, D.M. [Instituto de Fisica, Universidade de Sao Paulo, Sao Paulo 05315-970 (Brazil); Falleiros, A.M.F. [Centro de Ciencias Biologicas, Universidade Estadual de Londrina 86051-990 (Brazil); Salvador, V.L. [Centro de aplicacoes e Lasers, IPEN, Sao Paulo 05508-000 (Brazil)

    2008-05-01

    In this study, we evaluated the biodistribution and the elimination kinetics of a biocompatible magnetic fluid, Endorem{sup TM}, based on dextran-coated Fe{sub 3}O{sub 4} nanoparticles endovenously injected into Winstar rats. The iron content in blood and liver samples was recorded using electron paramagnetic resonance (EPR) and X-ray fluorescence (XRF) techniques. The EPR line intensity at g = 2.1 was found to be proportional to the concentration of magnetic nanoparticles and the best temperature for spectra acquisition was 298 K. Both EPR and XRF analysis indicated that the maximum concentration of iron in the liver occurred 95 min after the ferrofluid administration. The half-life of the magnetic nanoparticles (MNP) in the blood was (11.6 {+-} 0.6) min measured by EPR and (12.6 {+-} 0.6) min determined by XRF. These results indicate that both EPR and XRF are very useful and appropriate techniques for the study of kinetics of ferrofluid elimination and biodistribution after its administration into the organism.

  15. Use of molecular indicators of inflammation to assess the biocompatibility of all-ceramic restorations.

    Science.gov (United States)

    Ariaans, Kirsten; Heussen, Nicole; Schiffer, Hanna; Wienert, Anna-Lena; Plümäkers, Birgit; Rink, Lothar; Wolfart, Stefan

    2016-02-01

    The purpose of this in vivo study was quantification of inflammatory reaction to ceramic restorations made from lithium disilicate and zirconia by measurement of the concentration of indicators of inflammation in the gingival crevicular fluid (GCF). Patients out of three prospective cohort-studies investigating three different all-ceramic restoration materials for crowns and fixed dental prostheses were included. Patients needed an associated, unrestored tooth to serve as control. GCF samples were taken from the sulcus of the restored teeth and the related controls (n = 59 pairs) and the concentrations of IL1-beta, IL-1ra and aMMP-8, as indicators of inflammation, were determined by use of ELISA tests. Periodontal status was also assessed clinically by measurement of pocket depth (PD), plaque index (PI) and bleeding on probing (BOP). The concentrations of the inflammation indicators were not significantly different between restored teeth and controls or between lithium disilicate and zirconia restorations (p > 0.05). Furthermore, no significant difference between PD of restored teeth and controls or between groups could be shown. Within the limitation of the study, treatment with all-ceramic restorations did not induce inflammatory reactions in a group of periodontal healthy patients. No differences between the gingiva reactions of lithium disilicate and zirconia restorations could be shown. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  16. Biocompatibility of three bioabsorbable membranes assessed in FGH fibroblasts and human osteoblast like cells culture.

    Science.gov (United States)

    Soares, Michelle Pereira Costa Mundim; Soares, Paulo Vinícius; Pereira, Analice Giovani; Moura, Camilla Christian Gomes; Soares, Priscila Barbosa Ferreira; Naves, Lucas Zago; de Magalhães, Denildo

    2014-08-06

    Specific physical and chemical features of the membranes may influence the healing of periodontal tissues after guided tissue regeneration (GTR). The aim of the present investigation was to analyze the biological effects of three bioabsorbable membranes. The hypothesis is that all tested membranes present similar biological effects. Human osteoblast like-cells (SaOs-2) and gingival fibroblasts FGH (BCRJ -RJ) were cultured in DMEM medium. The viability of the cells cultured on the membranes was assesses using 3-(4,5-Dimethylthiazol-2-yl)-2,5-diphenyltetrazolium bromide (MTT). Quantitative determination of activated human Transforming Growth Factor beta 1 (TGF-β1) on the supernatants of the cell culture was observed. Samples were examined using scanning electron microscope (SEM). SaOs2, in 24 hours, PLA group showed higher values when compared to other groups (P statistical significance values when compared two times. In 4 h and 24 h, for the fibroblasts group, significantly difference was found to PLA membrane, when compared with the other groups (p statistically significant difference (p analysis of culture supernatants of fibroblasts, in 24 hours, only PLA group presented significant difference (p = 0,008). The biomaterials analyzed did not show cytotoxicity, since no membrane presented lower results than the control group. PLA membrane presented the best performance due to its higher cell viability and absorbance levels of proliferation. Both collagen membranes showed similar results either when compared to each other or to the control group.

  17. The biocompatibility of a polyelectrolyte vitreous body substitute on a high resistance in vitro model of the blood-retinal barrier.

    Science.gov (United States)

    Strotmann, Falko; Wolf, Isabel; Galla, Hans-Joachim

    2013-09-01

    The vitreous body can be regarded as a fascinating simple but important tissue, since it represents the main compartment of the eye and plays a crucial role for proper vision. Several diseases require its removal with following substitution using a liquid artificial vitreous body replacement. We explore the biocompatibility of a poly(AMPS-Na(+))-graft-poly(NIPAAm) polyelectrolyte following the innovative concept of thermo-responsive behaviour, exhibiting enhanced shear viscosity at physiological temperatures. As a powerful model for the blood-retinal barrier, we use the well-established in vitro cell culture model based on highly differentiated porcine brain capillary endothelial cells. Via the quantification of the transendothelial electrical resistance and immunocytochemical staining of tight junction proteins, we are able to show that a barrier integrity affecting impact of the polyelectrolyte was only transient and nearly reversible. Furthermore, the polyelectrolyte hydrogel is characterized by the absence of any acute cell morphology, cell vitality or proliferation affecting impacts. It does not trigger acute apoptotic processes, as can be substantiated via caspase-3 activity and DNA fragmentation assays. In view of the results of this study, it is shown that the polyelectrolyte does not affect the vitality parameters of our porcine brain capillary endothelial cells. It can be suggested that the tested thermo-responsive polyelectrolyte does not affect the sensitive retinal barrier integrity. Thus from the cellular tolerance it might serve as a potential liquid artificial vitreous body replacement to overcome the most prominent difficulties of common vitreal endotamponades.

  18. Indium arsenide as a material for biological applications: Assessment of surface modifications, toxicity, and biocompatibility

    Science.gov (United States)

    Jewett, Scott A.

    III-V semiconductors such as InAs have recently been employed in a variety of applications where the electronic and optical characteristics of traditional, silicon-based materials are inadequate. InAs has a narrow band gap and very high electron mobility in the near-surface region, which makes it very attractive for high performance transistors, optical applications, and chemical sensing. However, InAs forms an unstable surface oxide layer in ambient conditions, which can corrode over time and leach toxic indium and arsenic components. Current research has gone into making InAs more attractive for biological applications through passivation of the surface by adlayer adsorption. In particular, wet-chemical methods are current routes of exploration due to their simplicity, low cost, and flexibility in the type of passivating molecule. This dissertation focuses on surface modifications of InAs using wet-chemical methods in order to further its use in biological applications. First, the adsorption of collagen binding peptides and mixed peptide/thiol adlayers onto InAs was assessed. X-ray photoelectron spectroscopy (XPS) along with atomic force microscopy (AFM) data suggested that the peptides successfully adsorbed onto InAs, but were only able to block oxide regrowth to a relatively low extent. This low passivation ability is due to the lack of covalent bonds of the peptide to InAs, which are necessary to effectively block oxide regrowth. The addition of a thiol, in the form of mixed peptide/thiol adlayers greatly enhanced passivation of InAs while maintaining peptide presence on the surface. Thiols form tight, covalent bonds with InAs, which prevents oxide regrowth. The presence of the collagen-binding peptide on the surface opens the door to subsequent modification with collagen or polyelectrolyte-based adlayers. Next, the stability and toxicity of modified InAs substrates were determined using inductively coupled plasma mass spectrometry (ICP-MS) and zebrafish

  19. Evaluation of menstrual blood stem cells seeded in biocompatible Bombyx mori silk fibroin scaffold for cardiac tissue engineering.

    Science.gov (United States)

    Rahimi, Maryam; Mohseni-Kouchesfehani, Homa; Zarnani, Amir-Hassan; Mobini, Sahba; Nikoo, Shohreh; Kazemnejad, Somaieh

    2014-08-01

    Recently, silk fibroin scaffolds have been introduced as novel and promising biomaterials in the field of cardiac tissue engineering. This study was designed to compare infiltration, proliferation, and cardiac differentiation potential of menstrual blood-derived stem cells (MenSCs) versus bone marrow-derived mesenchymal stem cells (BMSCs) in Bombyx mori-derived silk scaffold. Our primary data revealed that the fabricated scaffold has mechanical and physical qualities suitable for cardiac tissue engineering. The MenSCs tracking in scaffolds using immunofluorescent staining and scanning electron microscopy confirmed MenSCs attachment, penetration, and distribution within the porous scaffold matrix. Based on proliferation assay using propidium iodide DNA quantification, the significantly higher level of growth rates of both MenSCs and BMSCs was documented in scaffolds than that in two-dimensional culture (p < 0.01). The expression level of TNNT2, a bona fide cardiac differentiation marker, in BMSCs differentiated on silk scaffolds was markedly higher than those cultured in two-dimensional culture indicating the improvement of cardiac differentiation in the silk scaffolds. Furthermore, differentiated MenSCs exhibited higher expression of TNNT2 compared with induced BMSCs. It seems that silk scaffold-seeded MenSCs could be viewed as a novel, safe, natural, and accessible construct for cardiac tissue engineering. © The Author(s) 2014 Reprints and permissions: sagepub.co.uk/journalsPermissions.nav.

  20. Coating with Autologous Plasma Improves Biocompatibility of Mesh Grafts In Vitro: Development Stage of a Surgical Innovation

    Directory of Open Access Journals (Sweden)

    Holger Gerullis

    2013-01-01

    Full Text Available Purpose. To investigate mesh coating modalities with autologous blood components in a recently developed in vitro test system for biocompatibility assessment of alloplastic materials. Materials and Methods. Seven different mesh types, currently used in various indications, were randomly investigated. Meshes were coated prior to cultivation with autologous peripheral blood mononuclear cells (PBMCs, platelets, and blood plasma. Pretreated meshes were incubated over 6 weeks in a minced tissue assay, representative for fibroblasts, muscle cells, and endothelial cells originating from 10 different patients. Adherence of those tissues on the meshes was microscopically investigated and semiquantitatively assessed using a previously described scoring system. Results. Coating with peripheral blood mononuclear cells did not affect the adherence score, whereas coating with platelets and blood plasma increased the score suggesting improved biocompatibility in vitro. The previous ranking of native meshes remained consistent after coating. Conclusion. Plasma coating of meshes improves their biocompatibility score in a novel in vitro test system.

  1. Effects of peritoneal dialysis fluid biocompatibility on baroreflex sensitivity.

    Science.gov (United States)

    John, S G; Selby, N M; McIntyre, C W

    2008-04-01

    Conventional low biocompatibility peritoneal dialysis (PD) fluid composition has been driven by manufacturing expediency and cost limitations. PD is associated with significant acute changes in cardiovascular functional parameters, at least in part influenced by fluid composition. Short-term control of blood pressure (BP) is under control of the baroreflex arc. The aim of this study was to investigate the effects of PD fluid biocompatibility on baroreflex sensitivity (BRS). We studied 10 non-diabetic established continuous ambulatory PD patients, in a randomized crossover trial comparing conventional and biocompatible PD fluids. Systemic hemodynamics were continuously monitored using digital pulse-wave analysis. Plasma glucose and insulin were assessed during treatment with both 1.36% and 3.86% glucose-containing fluids. BRS was calculated offline from continuous BP and interbeat interval data. BRS was significantly higher with conventional PD fluid during both 1.36% (Pinsulin concentrations, and ultrafiltration volumes were significantly higher during the 3.86% dwell than the 1.36% dwell, but there were no differences between standard and biocompatible fluids. We have demonstrated for the first time that PD fluid biocompatibility rapidly affects BRS. These changes occur against a background of cardiovascular variability, hyperinsulinemia, and hyperglycemia. Further research is needed to explore the mechanism and, more importantly, the consequences of these findings.

  2. Date Fruits-Assisted Synthesis and Biocompatibility Assessment of Nickel Oxide Nanoparticles Anchored onto Graphene Sheets for Biomedical Applications.

    Science.gov (United States)

    Alshatwi, Ali A; Athinarayanan, Jegan; Periasamy, Vaiyapuri Subbarayan; Alatiah, Khalid A

    2017-02-01

    Nanographene- and graphene-based nanohybrids have garnered attention in the biomedical community owing to their biocompatibility, excellent aqueous processability, ease of cellular uptake, facile surface functionalization, and thermal and electrical conductivities. NiO nanoparticle-graphene nanohybrid (G-NiO) was synthesized by first depositing Ni(OH)2 onto the surface of graphene oxide (GO) sheets. The Ni(OH)2-GO hybrids were then reduced to G-NiO using date palm syrup at 85 °C. The prepared G-NiO nanohybrids were characterized by X-ray diffraction (XRD), field-emission scanning electron microscopy (FESEM), Fourier transform infrared spectroscopy, and energy-dispersive X-ray spectroscopy (EDX). The NiO nanoparticles, with a diameter of approximately 20-30 nm, were uniformly dispersed over the surface of the graphene sheets. The G-NiO hybrids exhibit biocompatibility in human mesenchymal stem cells (hMSCs) up to 100 μg/mL. The nanohybrids do not cause any significant changes in cellular and nuclear morphologies in hMSCs. The as-synthesized nanohybrids show excellent biocompatibility and could be a promising material for biomedical applications.

  3. Nano-CeO2 decorated graphene based chitosan nanocomposites as enzymatic biosensing platform: fabrication and cellular biocompatibility assessment.

    Science.gov (United States)

    De, Sriparna; Mohanty, Smita; Nayak, Sanjay Kumar

    2015-09-01

    The present study summarizes the designing of a green transducer phase based on nano-cerium oxide (CeO2) decorated reduced graphene oxide (RGO) reinforced chitosan nanocomposites as an effective enzyme immobilizer and bio-sensing matrix for glucose analyte. Also, it scrutinizes the biocompatibility and cell viability of the synthesized nanohybrid with human fibroblastic macrophage cell line. CeO2 nanoparticles (NPs) were successfully grown on graphene nanosheet in the presence of cationic surfactant followed by facile hydrothermal treatment. The eventual growth of synthesized CeO2 nanocrystals on the graphene layer was confirmed from X-ray diffraction (XRD), transmission electron microscopy (TEM) and Raman analysis. The biocompatibility of the synthesized nanohybrid was also evident from the MTT assay. Glucose oxidase (GOx) was employed on the green polymer nanocomposites modified FTO electrode to fabricate an enzymatic bioelectrode. The electroanalytical response of the GOx/nano-CeO2/RGO/CS/FTO bioelectrode towards electrooxidation of glucose analyte was investigated by electrochemical impedance (EIS) and cyclic voltammetry (CV) study. The resulting biosensor exhibited a good electrochemical response to glucose within the linear detection range of 0.05-6.5 mM with a low detection limit of 2 μM and a sensitivity of 7.198 μA mM(-1) cm(-2). The bioelectrode also showed good shelf life (~10 weeks) and negligible interfering ability under controlled environment. The obtained results indicate that nano-CeO2/RGO nanohybrid based chitosan nanocomposites achieve a biocompatible biosensing platform for effective enzyme immobilization due to the excellent synergistic effects between the CeO2 nanoparticles and graphene sheet.

  4. Synthesis of Gold Mediated Biocompatible Nanocomposite of Lactone Enriched Fraction from Sahadevi (Vernonia cinerea Lees): An Assessment of Antimalarial Potential.

    Science.gov (United States)

    Jyotshna; Shanker, Karuna; Khare, Puja; Tiwari, Nimisha; Mohanty, Shilpa; Bawankule, Dnyaneshwar U; Pal, Anirban

    2016-01-01

    Metals reduction into submicro/nano size through bhasma preparations for therapeutic use is well established in ancient traditional system of Indian medicines i.e. Ayurveda. Recently, nanotechnology has drawn the attention of researchers to develeope various size and shape nanoparicles / composite for number of applications.In this article, we report the enrichment of lactone enriched fraction (LEF) by liquid-liquid portioning of Vernonia cinerea metabolic extract and sysnthesis of mediated nano-gold composite (LEF-AuNPs) in single step process. The morphological characteristic based on transmission electron microscope (TEM) image analysis showed that LEF-AuNPs were predominantly nanopolygons and nanobots in shapes ranging from 50-200 nm in size. Abundance of phytochemicals in both LEF and LEF-AuNPs was dissimilar. In LEF, montanol- a diterpenoid, while in LEF-AuNPs, neophytadiene- a phytanes was the major compound. HPLC profile of relatively polar compounds also varied drastically. In-vitro biocompatibility, cytotoxicity [MTT (3-[4,5-dimethylthiazol-2-yl]-2,5 diphenyl tetrazolium bromide) based assay] and storage stabilitiy of LEF-AuNPs were evaluated. The moderate ability of LEF-AuNPs to restrict parasitaemia, extended mean survival time of mice infected with Plasmodium berghei and lack of any evident toxicity provides new opportunities for the safe delivery and applications of such nanocomposites in malaria therapy.

  5. Quantitative photoacoustic characterization of blood clot in blood: A mechanobiological assessment through spectral information

    Science.gov (United States)

    Biswas, Deblina; Vasudevan, Srivathsan; Chen, George C. K.; Sharma, Norman

    2017-02-01

    Formation of blood clots, called thrombus, can happen due to hyper-coagulation of blood. Thrombi, while moving through blood vessels can impede blood flow, an important criterion for many critical diseases like deep vein thrombosis and heart attacks. Understanding mechanical properties of clot formation is vital for assessment of severity of thrombosis and proper treatment. However, biomechanics of thrombus is less known to clinicians and not very well investigated. Photoacoustic (PA) spectral response, a non-invasive technique, is proposed to investigate the mechanism of formation of blood clots through elasticity and also differentiate clots from blood. Distinct shift (increase in frequency) of the PA response dominant frequency during clot formation is reported. In addition, quantitative differentiation of blood clots from blood has been achieved through parameters like dominant frequency and spectral energy of PA spectral response. Nearly twofold increases in dominant frequency in blood clots compared to blood were found in the PA spectral response. Significant changes in energy also help in quantitatively differentiating clots from blood, in the blood. Our results reveal that increase in density during clot formation is reflected in the PA spectral response, a significant step towards understanding the mechanobiology of thrombus formation. Hence, the proposed tool, in addition to detecting thrombus formation, could reveal mechanical properties of the sample through quantitative photoacoustic spectral parameters.

  6. Observational assessment and correlates to blood pressure of future ...

    African Journals Online (AJOL)

    Observational assessment and correlates to blood pressure of future ... of undiagnosed hypertension among undergraduate medical students and to ... Family history of hypertension or diabetes mellitus was not associated with hypertension.

  7. Clinical assessment of intraarterial blood gas monitor accuracy

    Science.gov (United States)

    Aziz, Salim; Spiess, R.; Roby, Paul; Kenny, Margaret

    1993-08-01

    The accuracy of intraarterial blood gas monitoring (IABGM) devices is challenging to assess under routine clinical conditions. When comparing discrete measurements by blood gas analyzer (BGA) to IABGM values, it is important that the BGA determinations (reference method) be as accurate as possible. In vitro decay of gas tensions caused by delay in BGA analysis is particularly problematic for specimens with high arterial oxygen tension (PaO2) values. Clinical instability of blood gases in the acutely ill patient may cause disagreement between BGA and IABGM values because of IABGM response time lag, particularly in the measurement of arterial blood carbon dioxide tension (PaCO2). We recommend that clinical assessments of IABGM accuracy by comparison with BGA use multiple bedside BGA instruments, and that blood sampling only occur during periods when IABGM values appear stable.

  8. Hydration Status of Patients Dialyzed with Biocompatible Peritoneal Dialysis Fluids.

    Science.gov (United States)

    Lichodziejewska-Niemierko, Monika; Chmielewski, Michał; Dudziak, Maria; Ryta, Alicja; Rutkowski, Bolesław

    2016-01-01

    Biocompatible fluids for peritoneal dialysis (PD) have been introduced to improve dialysis and patient outcome in end-stage renal disease. However, their impact on hydration status (HS), residual renal function (RRF), and dialysis adequacy has been a matter of debate. The aim of the study was to evaluate the influence of a biocompatible dialysis fluid on the HS of prevalent PD patients. ♦ The study population consisted of 18 prevalent PD subjects, treated with standard dialysis fluids. At baseline, 9 patients were switched to a biocompatible solution, low in glucose degradation products (GDPs) (Balance; Fresenius Medical Care, Bad Homburg, Germany). Hydration status was assessed through clinical evaluation, laboratory parameters, echocardiography, and bioimpedance spectroscopy over a 24-month observation period. ♦ During the study period, urine volume decreased similarly in both groups. At the end of the evaluation, there were also no differences in clinical (body weight, edema, blood pressure), laboratory (N-terminal pro-brain natriuretic peptide, NTproBNP), or echocardiography determinants of HS. However, dialysis ultrafiltration decreased in the low-GDP group and, at the end of the study, equaled 929 ± 404 mL, compared with 1,317 ± 363 mL in the standard-fluid subjects (p = 0.06). Hydration status assessed by bioimpedance spectroscopy was +3.64 ± 2.08 L in the low-GDP patients and +1.47 ± 1.61 L in the controls (p = 0.03). ♦ The use of a low-GDP biocompatible dialysis fluid was associated with a tendency to overhydration, probably due to diminished ultrafiltration in prevalent PD patients. Copyright © 2016 International Society for Peritoneal Dialysis.

  9. Current Imaging Modalities for assessing Ocular Blood Flow in Glaucoma

    OpenAIRE

    Mohindroo, Chirayu; Ichhpujani, Parul; Kumar, Suresh

    2016-01-01

    Glaucoma may be caused by an interplay of elevated intraocular pressure (IOP), vascular, genetic, anatomical, brain, and immune factors. The direct assessment of ocular hemodynam-ics offers promise for glaucoma detection, differentiation, and possibly new treatment modalities. All the methods currently in use to measure ocular blood flow have inherent limitations and measure different aspects of ocular blood flow. This review article attempts to provide detailed information on ocular perfu-si...

  10. Hematologic assessment in pet rats, mice, hamsters, and gerbils: blood sample collection and blood cell identification.

    Science.gov (United States)

    Lindstrom, Nicole M; Moore, David M; Zimmerman, Kurt; Smith, Stephen A

    2015-01-01

    Hamsters, gerbils, rats, and mice are presented to veterinary clinics and hospitals for prophylactic care and treatment of clinical signs of disease. Physical examination, history, and husbandry practice information can be supplemented greatly by assessment of hematologic parameters. As a resource for veterinarians and their technicians, this article describes the methods for collection of blood, identification of blood cells, and interpretation of the hemogram in mice, rats, gerbils, and hamsters.

  11. Hematological Assessment in Pet Guinea Pigs (Cavia porcellus): Blood Sample Collection and Blood Cell Identification.

    Science.gov (United States)

    Zimmerman, Kurt; Moore, David M; Smith, Stephen A

    2015-09-01

    Pet guinea pigs are presented to veterinary clinics for routine care and treatment of clinical diseases. In addition to obtaining clinical history and exam findings, diagnostic testing may be required, including hematological assessments. This article describes common blood collection methods, including venipuncture sites, the volume of blood that can be safely collected, and handling of the blood. Hematological parameters for normal guinea pigs are provided for comparison with in-house or commercial test results. A description of the morphology of guinea pig leukocytes is provided to assist in performing a differential count.

  12. Quality Assessment of Established and Emerging Blood Components for Transfusion

    Science.gov (United States)

    Marks, Denese C.

    2016-01-01

    Blood is donated either as whole blood, with subsequent component processing, or through the use of apheresis devices that extract one or more components and return the rest of the donation to the donor. Blood component therapy supplanted whole blood transfusion in industrialized countries in the middle of the twentieth century and remains the standard of care for the majority of patients receiving a transfusion. Traditionally, blood has been processed into three main blood products: red blood cell concentrates; platelet concentrates; and transfusable plasma. Ensuring that these products are of high quality and that they deliver their intended benefits to patients throughout their shelf-life is a complex task. Further complexity has been added with the development of products stored under nonstandard conditions or subjected to additional manufacturing steps (e.g., cryopreserved platelets, irradiated red cells, and lyophilized plasma). Here we review established and emerging methodologies for assessing blood product quality and address controversies and uncertainties in this thriving and active field of investigation. PMID:28070448

  13. Quality Assessment of Established and Emerging Blood Components for Transfusion.

    Science.gov (United States)

    Acker, Jason P; Marks, Denese C; Sheffield, William P

    2016-01-01

    Blood is donated either as whole blood, with subsequent component processing, or through the use of apheresis devices that extract one or more components and return the rest of the donation to the donor. Blood component therapy supplanted whole blood transfusion in industrialized countries in the middle of the twentieth century and remains the standard of care for the majority of patients receiving a transfusion. Traditionally, blood has been processed into three main blood products: red blood cell concentrates; platelet concentrates; and transfusable plasma. Ensuring that these products are of high quality and that they deliver their intended benefits to patients throughout their shelf-life is a complex task. Further complexity has been added with the development of products stored under nonstandard conditions or subjected to additional manufacturing steps (e.g., cryopreserved platelets, irradiated red cells, and lyophilized plasma). Here we review established and emerging methodologies for assessing blood product quality and address controversies and uncertainties in this thriving and active field of investigation.

  14. Quality Assessment of Established and Emerging Blood Components for Transfusion

    Directory of Open Access Journals (Sweden)

    Jason P. Acker

    2016-01-01

    Full Text Available Blood is donated either as whole blood, with subsequent component processing, or through the use of apheresis devices that extract one or more components and return the rest of the donation to the donor. Blood component therapy supplanted whole blood transfusion in industrialized countries in the middle of the twentieth century and remains the standard of care for the majority of patients receiving a transfusion. Traditionally, blood has been processed into three main blood products: red blood cell concentrates; platelet concentrates; and transfusable plasma. Ensuring that these products are of high quality and that they deliver their intended benefits to patients throughout their shelf-life is a complex task. Further complexity has been added with the development of products stored under nonstandard conditions or subjected to additional manufacturing steps (e.g., cryopreserved platelets, irradiated red cells, and lyophilized plasma. Here we review established and emerging methodologies for assessing blood product quality and address controversies and uncertainties in this thriving and active field of investigation.

  15. Biocompatibility Assessment of Poly(lactic acid) Films after Sterilization with Ethylene Oxide in Histological Study In Vivo with Wistar Rats and Cellular Adhesion of Fibroblasts In Vitro

    National Research Council Canada - National Science Library

    Michele Savaris; Gustavo L. Braga; Venina dos Santos; Glaucio A. Carvalho; Asdrubal Falavigna; Denise C. Machado; Christian Viezzer; Rosmary N. Brandalise

    2017-01-01

    .... The biocompatibility of poly(lactic acid) (PLA) films, shaped by compression, was evaluated after sterilization by ethylene oxide by a histological in vivo test with Wistar rats and cytotoxicity in cell adhesion in vitro...

  16. The prevalence and assessment of blood transfusions in newborns

    Directory of Open Access Journals (Sweden)

    Hajieh Borna

    2017-06-01

    Full Text Available Background: Blood transfusion is common in infants. Due to the weakened immune system of newborns and the risk of blood transfusion complications, it is necessary to pay more attention following or after to blood transfusion. The aim of this study was to evaluate the frequency and risk factors of blood transfusions in hospitalized neonates. Methods: A cross-sectional study was performed on 1106 infants admitted in the neonatal intensive care unit (NICU of Mustafa Khomeini University Hospital, Tehran, Iran, from spring 2009 to 2012. Frequency and the reason for of blood components transfusion including fresh frozen plasma, platelets, whole blood, packed red blood cells, cryoprecipitate and relationship with gestational age, sex, birth weight, Apgar score, duration of hospitalization, use of mechanical ventilation were assessed. Statistical analysis was performed with SPSS statistical software, version 16 (IBM, Armonk, NY, USA and statistical test, chi-square test, independent t-test and analysis of variance (ANOVA. Results: Among 1106 infants admitted to the neonatal intensive care unit, 221 infants (%19.98 received blood products. 82 of all (37% were female and 139 (%63 were female. 113 (51% of neonate were preterm and 108 (48% were term. From 361 times of blood transfusions, 121 infant (54.75% received at least one blood product. The frequency of blood transfusion was between 39 and 1 times, with an average of 3.65 times per infant. Frequency of fresh frozen plasma infusion was 173 (47.9%, packed cell 122 (33%, platelet 32 (8.8%, cryoprecipitate 20 (5.1% and whole blood 3 unit (0.83%. The most common causes for fresh frozen plasma transfusion was replacement therapy 140 (80%, for packed cell, to correct symptomatic anemia 68 (55.6%, for platelet transfusions was to prevent bleeding in  neonates with thrombocytopenia 20 (62.5% and cryoprecipitate for bleeding caused by DIC in 18 infant (90%. There was significant relation between frequency of

  17. Biocompatibility Assessment of Novel Bioresorbable Alloys Mg-Zn-Se and Mg-Zn-Cu for Endovascular Applications: In- Vitro Studies

    OpenAIRE

    Persaud-Sharma, Dharam; Budiansky, Noah; McGoron, Anthony J

    2013-01-01

    Previous studies have shown that using biodegradable magnesium alloys such as Mg-Zn and Mg-Zn-Al possess the appropriate mechanical properties and biocompatibility to serve in a multitude of biological applications ranging from endovascular to orthopedic and fixation devices. The objective of this study was to evaluate the biocompatibility of novel as-cast magnesium alloys Mg-1Zn-1Cu wt.% and Mg-1Zn-1Se wt.% as potential implantable biomedical materials, and compare their biologically effecti...

  18. Donor Infectious Disease Testing Multinational assessment of blood ...

    African Journals Online (AJOL)

    Donor Infectious Disease Testing Multinational assessment of blood-borne virus testing and transfusion safety on the African continent... ... AFRICAN JOURNALS ONLINE (AJOL) · Journals · Advanced Search · USING AJOL · RESOURCES ... for poor quality, to define a consensus strategy based on appropriate assays; and

  19. Biocompatibility of composite resins

    OpenAIRE

    Sayed Mostafa Mousavinasab

    2011-01-01

    Dental materials that are used in dentistry should be harmless to oral tissues, so they should not contain any leachable toxic and diffusible substances that can cause some side effects. Reports about probable biologic hazards, in relation to dental resins, have increased interest to this topic in dentists. The present paper reviews the articles published about biocompatibility of resin-restorative materials specially resin composites and monomers which are mainly based on Bis-GMA and concern...

  20. Biocompatible implant surface treatments.

    Science.gov (United States)

    Pattanaik, Bikash; Pawar, Sudhir; Pattanaik, Seema

    2012-01-01

    Surface plays a crucial role in biological interactions. Surface treatments have been applied to metallic biomaterials in order to improve their wear properties, corrosion resistance, and biocompatibility. A systematic review was performed on studies investigating the effects of implant surface treatments on biocompatibility. We searched the literature using PubMed, electronic databases from 1990 to 2009. Key words such as implant surface topography, surface roughness, surface treatment, surface characteristics, and surface coatings were used. The search was restricted to English language articles published from 1990 to December 2009. Additionally, a manual search in the major dental implant journals was performed. When considering studies, clinical studies were preferred followed by histological human studies, animal studies, and in vitro studies. A total of 115 articles were selected after elimination: clinical studies, 24; human histomorphometric studies, 11; animal histomorphometric studies, 46; in vitro studies, 34. The following observations were made in this review: · The focus has shifted from surface roughness to surface chemistry and a combination of chemical manipulations on the porous structure. More investigations are done regarding surface coatings. · Bone response to almost all the surface treatments was favorable. · Future trend is focused on the development of osteogenic implant surfaces. Limitation of this study is that we tried to give a broader overview related to implant surface treatments. It does not give any conclusion regarding the best biocompatible implant surface treatment investigated till date. Unfortunately, the eventually selected studies were too heterogeneous for inference of data.

  1. Assessment of maternal cerebral blood flow in patients with preeclampsia

    Directory of Open Access Journals (Sweden)

    Mandić Vesna

    2005-01-01

    Full Text Available Introduction Systemic vasoconstrktion in preeclamptic patients increases vascular resistance, and is manifested by increased arterial blood flow velocity. The aim of the study is to evaluate if there is a change of Doppler indices in maternal medial cerbral artery (MCA in severe preeclampsia due to: 1 severity of clinical symptoms, 2 the beginning of eclamptic attack and 3 the application of anticonvidsive therapy. Material and methods A prospective clinical study included 92 pregnant women, gestational age 28-36 weeks. They were divided into three groups: normotensive (n=30, mild preeclampsia (n=33, and severe preeclampsia (n=29. We investigated maternal cerebral circulation by assessing the MCA. We registrated: pulsatility index (Pi, resistance index (Ri, Systolic/diastolic ratio (S/D, and the maximum systolic, end diastolic and medium velocity. Patients with severe preeclampsia were divided into two subgroups: subgroup 1 included patients without symptoms of threatening eclampsia (n=18; 62.06%; while subgroup 2 included those with symptoms of preeclampsia (n=11; 37.94%. All patients with severe preeclampsia were treated with magnesium sulfate (MgSO4, and cerebral blood flow was measured before and after the treatment. Statistical analysis was done by oneway ANOVA, Student t-test and t-paired sample test. The difference was considered to be significant if p < 0.05. Results Significantly increased Pi, Ri and all velocities were established in the group of patients with severe preeclampsia compared with the other two groups. In the group with severe preeclamsia we registrated significantly increased values of all velocities (patients with signs of threatening eclampsia. After MgSO4 treatment in patients with severe preeclampsia significantly decreased values of Pi, Ri, S/D ratio and all velocities were registered. Discussion In the studied group of patients with severe preclampsia we found increased velocity values, Pi and Ri, especially in

  2. Biocompatibility Assessment of Poly(lactic acid Films after Sterilization with Ethylene Oxide in Histological Study In Vivo with Wistar Rats and Cellular Adhesion of Fibroblasts In Vitro

    Directory of Open Access Journals (Sweden)

    Michele Savaris

    2017-01-01

    Full Text Available Biomaterials must meet certain fundamental requirements for their usage in living beings, such as biocompatibility, bifunctionality, and sterilizability, without having chemical and structural changes. The biocompatibility of poly(lactic acid (PLA films, shaped by compression, was evaluated after sterilization by ethylene oxide by a histological in vivo test with Wistar rats and cytotoxicity in cell adhesion in vitro. The cytotoxicity test was performed by the reduction of tetrazolium salt (MTT. Thermal and chemical changes in PLA films concerning the proposed sterilization process and characteristics were not observed to evidence polymer degradation due to sterilization. The analysis of the cytotoxicity by the MTT method has shown that the sterilized PLA films are not cytotoxic. The adhesion and proliferation of fibroblasts on PLA films were homogeneously distributed over the evaluation period, showing an elongated appearance with unnumbered cytoplasmic extensions and cell-cell interactions. By examining the biocompatibility in a histological study, a mild tissue inflammation was observed with the presence of fibrosis in the samples that had been exposed for 21 days in the rats’ bodies. PLA films sterilized with ethylene oxide did not exhibit cell adhesion in vitro and toxicity to the surrounding tissue in vivo and they may be used in future in vivo testing, according to histological findings in Wistar rats in the present study.

  3. Biocompatibility of composite resins

    Directory of Open Access Journals (Sweden)

    Sayed Mostafa Mousavinasab

    2011-01-01

    Full Text Available Dental materials that are used in dentistry should be harmless to oral tissues, so they should not contain any leachable toxic and diffusible substances that can cause some side effects. Reports about probable biologic hazards, in relation to dental resins, have increased interest to this topic in dentists. The present paper reviews the articles published about biocompatibility of resin-restorative materials specially resin composites and monomers which are mainly based on Bis-GMA and concerns about their degradation and substances which may be segregated into oral cavity.

  4. Quantitative photoacoustic assessment of red blood cell aggregation under pulsatile blood flow: experimental and theoretical approaches

    Science.gov (United States)

    Bok, Tae-Hoon; Hysi, Eno; Kolios, Michael C.

    2017-03-01

    In the present paper, the optical wavelength dependence on the photoacoustic (PA) assessment of the pulsatile blood flow was investigated by means of the experimental and theoretical approaches analyzing PA radiofrequency spectral parameters such as the spectral slope (SS) and mid-band fit (MBF). For the experimental approach, the pulsatile flow of human whole blood at 60 bpm was imaged using the VevoLAZR system (40-MHz-linear-array probe, 700-900 nm illuminations). For the theoretical approach, a Monte Carlo simulation for the light transmit into a layered tissue phantom and a Green's function based method for the PA wave generation was implemented for illumination wavelengths of 700, 750, 800, 850 and 900 nm. The SS and MBF for the experimental results were compared to theoretical ones as a function of the illumination wavelength. The MBF increased with the optical wavelength in both theory and experiments. This was expected because the MBF is representative of the PA magnitude, and the PA signal from red blood cell (RBC) is dependent on the molar extinction coefficient of oxyhemoglobin. On the other hand, the SS decreased with the wavelength, even though the RBC size (absorber size which is related to the SS) cannot depend on the illumination wavelength. This conflicting result can be interpreted by means of the changes of the fluence pattern for different illumination wavelengths. The SS decrease with the increasing illumination wavelength should be further investigated.

  5. Variability in blood and blood component utilization as assessed by an anesthesia information management system.

    Science.gov (United States)

    Frank, Steven M; Savage, Will J; Rothschild, Jim A; Rivers, Richard J; Ness, Paul M; Paul, Sharon L; Ulatowski, John A

    2012-07-01

    Data can be collected for various purposes with anesthesia information management systems. The authors describe methods for using data acquired from an anesthesia information management system to assess intraoperative utilization of blood and blood components. Over an 18-month period, data were collected on 48,086 surgical patients at a tertiary care academic medical center. All data were acquired with an automated anesthesia recordkeeping system. Detailed reports were generated for blood and blood component utilization according to surgical service and surgical procedure, and for individual surgeons and anesthesiologists. Transfusion hemoglobin trigger and target concentrations were compared among surgical services and procedures, and between individual medical providers. For all patients given erythrocytes, the mean transfusion hemoglobin trigger was 8.4 ± 1.5, and the target was 10.2 ± 1.5 g/dl. Variation was significant among surgical services (trigger range: 7.5 ± 1.2-9.5 ± 1.1, P = 0.0001; target range: 9.1 ± 1.2-11.3 ± 1.4 g/dl, P = 0.002), surgeons (trigger range: 7.2 ± 0.7-9.8 ± 1.0, P = 0.001; target range: 8.8 ± 0.9-11.8 ± 1.3 g/dl, P = 0.001), and anesthesiologists (trigger range: 7.2 ± 0.8-9.6 ± 1.2, P = 0.001; target range: 9.0 ± 0.9-11.7 ± 1.3 g/dl, P = 0.0004). The use of erythrocyte salvage, fresh frozen plasma, and platelets varied threefold to fourfold among individual surgeons compared with their peers performing the same surgical procedure. The use of data acquired from an anesthesia information management system allowed a detailed analysis of blood component utilization, which revealed significant variation among surgical services and surgical procedures, and among individual anesthesiologists and surgeons compared with their peers. Incorporating these methods of data acquisition and analysis into a blood management program could reduce unnecessary transfusions, an outcome that may increase patient safety and reduce costs.

  6. Application and biocompatibility of a new absorbable magnesium alloy stent in blood vessels%新型可吸收镁合金支架在血管内应用及生物相容性

    Institute of Scientific and Technical Information of China (English)

    赵辉; 雷民

    2016-01-01

    BACKGROUND: In vivo animal experiments have found that magnesium al oy stents can be completely degraded in a slow, orderly and non-toxic manner fol owing the vascular remodeling. OBJECTIVE: To investigate the applied effect and biocompatibility of a new type of magnesium al oy stent in blood vessels. METHODS: Forty-two crossbreed dogs were implanted with absorbable magnesium al oy stents via the coronary artery or left femoral artery. At days 1, 3, 5 and weeks 1, 2, 3, 4 after implantation, coronary or femoral artery angiography, inflammatory factor detection and morphological analysis targeting intimal hyperplasia were performed. RESULTS AND CONCLUSION: At 1 day after implantation, the stents had the complete shape and were ful y extended; at 3 days after implantation, the stents were degraded partial y; at 1 week after implantation, the stents were degraded completely. Within 1-3 weeks after implantation, the levels of tumor necrosis factor α, interleukin-6 and interleukin-8 continued to decrease. At 2 and 3 weeks after implantation, the target vessels presented with mild intimal hyperplasia. As time went on, the hyperplasia area increased gradual y, and the percentage of intimal hyperplasia increased gradual y. Blood magnesium concentration remained unchanged before and after stent implantation. The results show that the new absorbable magnesium al oy stent can be completely degraded within 1 week after stent implantation and has good biocompatibility.%背景:动物体内实验发现,可吸收镁合金支架随着血管结构重塑的完成,可通过缓慢、有序、无毒害降解方式在体内完全降解。目的:探讨新型血管内可吸收镁合金支架在血管内的应用效果及生物相容性。方法:取42只防疫杂种犬,均于冠状动脉或者左侧股动脉置入可吸收镁合金支架,置入后1 d、3 d、5 d、1周、2周、3周、4周,进行冠状动脉或股动脉造影、炎性因子检测及靶血管内膜增生面

  7. Biocompatibility of Niobium Coatings

    Directory of Open Access Journals (Sweden)

    René Olivares-Navarrete

    2011-09-01

    Full Text Available Niobium coatings deposited by magnetron sputtering were evaluated as a possible surface modification for stainless steel (SS substrates in biomedical implants. The Nb coatings were deposited on 15 mm diameter stainless steel substrates having an average surface roughness of 2 mm. To evaluate the biocompatibility of the coatings three different in vitro tests, using human alveolar bone derived cells, were performed: cellular adhesion, proliferation and viability. Stainless steel substrates and tissue culture plastic were also studied, in order to give comparative information. No toxic response was observed for any of the surfaces, indicating that the Nb coatings act as a biocompatible, bioinert material. Cell morphology was also studied by immune-fluorescence and the results confirmed the healthy state of the cells on the Nb surface. X-ray diffraction analysis of the coating shows that the film is polycrystalline with a body centered cubic structure. The surface composition and corrosion resistance of both the substrate and the Nb coating were also studied by X-ray photoelectron spectroscopy and potentiodynamic tests. Water contact angle measurements showed that the Nb surface is more hydrophobic than the SS substrate.

  8. Blood compatibility of zinc-calcium phosphate conversion coating on Mg-1.33Li-0.6Ca alloy

    Science.gov (United States)

    Zou, Yu-Hong; Zeng, Rong-Chang; Wang, Qing-Zhao; Liu, Li-Jun; Xu, Qian-Qian; Wang, Chuang; Liu, Zhi-Wei

    2016-09-01

    Magnesium alloys as a new class of biomaterials possess biodegradability and biocompatibility in comparison with currently used metal implants. However, their rapid corrosion rates are necessary to be manipulated by appropriate coatings. In this paper, a new attempt was used to develop a zinc-calcium phosphate (Zn-Ca-P) conversion coating on Mg-1.33Li-0.6Ca alloys to increase the biocompatibility and improve the corrosion resistance. In vitro blood biocompatibility of the alloy with and without the Zn-Ca-P coating was investigated to determine its suitability as a degradable medical biomaterial. Blood biocompatibility was assessed from the hemolysis test, the dynamic cruor time test, blood cell count and SEM observation of the platelet adhesion to membrane surface. The results showed that the Zn-Ca-P coating on Mg-1.33Li-0.6Ca alloys had good blood compatibility, which is in accordance with the requirements for medical biomaterials.

  9. Construction and accuracy assessment of patient-specific biocompatible drill template for cervical anterior transpedicular screw (ATPS insertion: an in vitro study.

    Directory of Open Access Journals (Sweden)

    Maoqing Fu

    Full Text Available BACKGROUND: With the properties of three-column fixation and anterior-approach-only procedure, anterior transpedicular screw (ATPS is ideal for severe multilevel traumatic cervical instabilities. However, the accurate insertion of ATPS remains challenging. Here we constructed a patient-specific biocompatible drill template and evaluated its accuracy in assisting ATPS insertion. METHODS: After ethical approval, 24 formalin-preserved cervical vertebrae (C2-C7 were CT scanned. 3D reconstruction models of cervical vertebra were obtained with 2-mm-diameter virtual pin tracts at the central pedicles. The 3D models were used for rapid prototyping (RP printing. A 2-mm-diameter Kirschner wire was then inserted into the pin tract of the RP model before polymethylmethacrylate was used to construct the patient-specific biocompatible drill template. After removal of the anterior soft tissue, a 2-mm-diameter Kirschner wire was inserted into the cervical pedicle with the assistance of drill template. Cadaveric cervical spines with pin tracts were subsequently scanned using the same CT scanner. A 3D reconstruction was performed of the scanned spines to get 3D models of the vertebrae containing the actual pin tracts. The deviations were calculated between 3D models with virtual and actual pin tracts at the middle point of the cervical pedicle. 3D models of 3.5 mm-diameter screws were used in simulated insertion to grade the screw positions. FINDINGS: The patient-specific biocompatible drill template was constructed to assist ATPS insertion successfully. There were no significant differences between medial/lateral deviations (P = 0.797 or between superior/inferior deviations (P = 0.741. The absolute deviation values were 0.82±0.75 mm and 1.10±0.96 mm in axial and sagittal planes, respectively. In the simulated insertion, the screws in non-critical position were 44/48 (91.7%. CONCLUSIONS: The patient-specific drill template is biocompatible, easy

  10. Self-assembled antimicrobial and biocompatible copolymer films on titanium.

    Science.gov (United States)

    Pfaffenroth, Cornelia; Winkel, Andreas; Dempwolf, Wibke; Gamble, Lara J; Castner, David G; Stiesch, Meike; Menzel, Henning

    2011-11-10

    Copolymers of 4-vinyl-N-hexylpyridinium bromide and dimethyl(2-methacryloyloxyethyl) phosphonate self-assemble to form ultrathin layers on titanium surfaces that show antimicrobial activity, and biocompatibility. The copolymer layers are characterized by contact angle measurements, ellipsometry and XPS. Antibacterial activity is assessed by investigation of adherence of S. mutans. Biocompatibility is rated based on human gingival fibroblast adhesion and proliferation. By balancing the opposing effects of the chemical composition on biocompatibility and antimicrobial activity, copolymer coatings are fabricated that are able to inhibit the growth of S. mutans on the surface but still show attachment of gingival fibroblasts, and therefore might prevent biofilm formation on implants.

  11. Biocompatibility of Resin-based Dental Materials

    OpenAIRE

    Keyvan Moharamzadeh; Ian M. Brook; Richard van Noort

    2009-01-01

    Oral and mucosal adverse reactions to resin-based dental materials have been reported. Numerous studies have examined thebiocompatibility of restorative dental materials and their components, and a wide range of test systems for the evaluation of the biological effects of these materials have been developed. This article reviews the biological aspects of resin-based dental materials and discusses the conventional as well as the new techniques used for biocompatibility assessment of dental mat...

  12. Assessing ABO/Rh Blood Group Frequency and Association with Asymptomatic Malaria among Blood Donors Attending Arba Minch Blood Bank, South Ethiopia

    Directory of Open Access Journals (Sweden)

    Getaneh Alemu

    2016-01-01

    Full Text Available Background. Determination of the various ABO/Rh blood group distributions and their association with malaria infection has paramount importance in the context of transfusion medicine and malaria control. Methods. Facility based cross-sectional study was conducted from February to June, 2015, to assess ABO/Rh blood groups distribution and their association with asymptomatic malaria. A structured questionnaire was used to collect data. Blood grouping was done using monoclonal antibodies. Thin and thick blood films were examined for Plasmodium parasites. Data were analyzed using SPSS version 20.0. Results. A total of 416 blood donors participated with median age of 22±0.29 (median ± standard error of the mean. Distribution of ABO phenotypes, in decreasing order, was O (175, 42.1%, A (136, 32.7%, B (87, 20.9%, and AB (18, 4.3%. Most of them were Rh+ (386, 92.8%. The overall malaria prevalence was 4.1% (17/416. ABO blood group is significantly associated with malaria infection (P=0.022. High rate of parasitemia was seen in blood group O donors (6.899, P=0.003 compared to those with other ABO blood groups. Conclusion. Blood groups O and AB phenotypes are the most and the least ABO blood groups, respectively. There is significant association between ABO blood group and asymptomatic malaria parasitemia.

  13. Assessing ABO/Rh Blood Group Frequency and Association with Asymptomatic Malaria among Blood Donors Attending Arba Minch Blood Bank, South Ethiopia.

    Science.gov (United States)

    Alemu, Getaneh; Mama, Mohammedaman

    2016-01-01

    Background. Determination of the various ABO/Rh blood group distributions and their association with malaria infection has paramount importance in the context of transfusion medicine and malaria control. Methods. Facility based cross-sectional study was conducted from February to June, 2015, to assess ABO/Rh blood groups distribution and their association with asymptomatic malaria. A structured questionnaire was used to collect data. Blood grouping was done using monoclonal antibodies. Thin and thick blood films were examined for Plasmodium parasites. Data were analyzed using SPSS version 20.0. Results. A total of 416 blood donors participated with median age of 22 ± 0.29 (median ± standard error of the mean). Distribution of ABO phenotypes, in decreasing order, was O (175, 42.1%), A (136, 32.7%), B (87, 20.9%), and AB (18, 4.3%). Most of them were Rh+ (386, 92.8%). The overall malaria prevalence was 4.1% (17/416). ABO blood group is significantly associated with malaria infection (P = 0.022). High rate of parasitemia was seen in blood group O donors (6.899, P = 0.003) compared to those with other ABO blood groups. Conclusion. Blood groups O and AB phenotypes are the most and the least ABO blood groups, respectively. There is significant association between ABO blood group and asymptomatic malaria parasitemia.

  14. Biocompatibility Assessment of Novel Bioresorbable Alloys Mg-Zn-Se and Mg-Zn-Cu for Endovascular Applications: In- Vitro Studies

    Science.gov (United States)

    Budiansky, Noah; McGoron, Anthony J.

    2013-01-01

    Previous studies have shown that using biodegradable magnesium alloys such as Mg-Zn and Mg-Zn-Al possess the appropriate mechanical properties and biocompatibility to serve in a multitude of biological applications ranging from endovascular to orthopedic and fixation devices. The objective of this study was to evaluate the biocompatibility of novel as-cast magnesium alloys Mg-1Zn-1Cu wt.% and Mg-1Zn-1Se wt.% as potential implantable biomedical materials, and compare their biologically effective properties to a binary Mg-Zn alloy. The cytotoxicity of these experimental alloys was evaluated using a tetrazolium based- MTS (3-(4,5-dimethylthiazol-2-yl)-5-(3-carboxymethoxyphenyl)-2-(4-sulfophenyl)-2H-tetrazolium) assay and a lactate dehydrogenase membrane integrity assay (LDH). The MTS assay was performed on extract solutions obtained from a 30-day period of alloy immersion and agitation in simulated body fluid to evaluate the major degradation products eluted from the alloy materials. Human foreskin fibroblast cell growth on the experimental magnesium alloys was evaluated for a 72 hour period, and cell death was quantified by measuring lactate dehydrogenase concentrations. Both Mg-Zn-Se and Mg-Zn-Cu alloys exhibit low cytotoxicity levels which are suitable for biomaterial applications. The Mg-Zn-Cu alloy was found to completely degrade within 72 hours, resulting in lower human foreskin fibroblast cell viability. The Mg-Zn-Se alloy was shown to be less cytotoxic than both the Mg-Zn-Cu and Mg-Zn alloys. PMID:24058329

  15. Biocompatibility Assessment of Novel Bioresorbable Alloys Mg-Zn-Se and Mg-Zn-Cu for Endovascular Applications: In- Vitro Studies.

    Science.gov (United States)

    Persaud-Sharma, Dharam; Budiansky, Noah; McGoron, Anthony J

    2013-01-01

    Previous studies have shown that using biodegradable magnesium alloys such as Mg-Zn and Mg-Zn-Al possess the appropriate mechanical properties and biocompatibility to serve in a multitude of biological applications ranging from endovascular to orthopedic and fixation devices. The objective of this study was to evaluate the biocompatibility of novel as-cast magnesium alloys Mg-1Zn-1Cu wt.% and Mg-1Zn-1Se wt.% as potential implantable biomedical materials, and compare their biologically effective properties to a binary Mg-Zn alloy. The cytotoxicity of these experimental alloys was evaluated using a tetrazolium based- MTS (3-(4,5-dimethylthiazol-2-yl)-5-(3-carboxymethoxyphenyl)-2-(4-sulfophenyl)-2H-tetrazolium) assay and a lactate dehydrogenase membrane integrity assay (LDH). The MTS assay was performed on extract solutions obtained from a 30-day period of alloy immersion and agitation in simulated body fluid to evaluate the major degradation products eluted from the alloy materials. Human foreskin fibroblast cell growth on the experimental magnesium alloys was evaluated for a 72 hour period, and cell death was quantified by measuring lactate dehydrogenase concentrations. Both Mg-Zn-Se and Mg-Zn-Cu alloys exhibit low cytotoxicity levels which are suitable for biomaterial applications. The Mg-Zn-Cu alloy was found to completely degrade within 72 hours, resulting in lower human foreskin fibroblast cell viability. The Mg-Zn-Se alloy was shown to be less cytotoxic than both the Mg-Zn-Cu and Mg-Zn alloys.

  16. Electrospinning of Biocompatible Nanofibers

    Science.gov (United States)

    Coughlin, Andrew J.; Queen, Hailey A.; McCullen, Seth D.; Krause, Wendy E.

    2006-03-01

    Artificial scaffolds for growing cells can have a wide range of applications including wound coverings, supports in tissue cultures, drug delivery, and organ and tissue transplantation. Tissue engineering is a promising field which may resolve current problems with transplantation, such as rejection by the immune system and scarcity of donors. One approach to tissue engineering utilizes a biodegradable scaffold onto which cells are seeded and cultured, and ideally develop into functional tissue. The scaffold acts as an artificial extracellular matrix (ECM). Because a typical ECM contains collagen fibers with diameters of 50-500 nm, electrostatic spinning (electrospinning) was used to mimic the size and structure of these fibers. Electrospinning is a novel way of spinning a nonwoven web of fibers on the order of 100 nm, much like the web of collagen in an ECM. We are investigating the ability of several biocompatible polymers (e.g., chitosan and polyvinyl alcohol) to form defect-free nanofiber webs and are studying the influence of the zero shear rate viscosity, molecular weight, entanglement concentration, relaxation time, and solvent on the resulting fiber size and morphology.

  17. Biocompatibility of Coronary Stents

    Directory of Open Access Journals (Sweden)

    Thamarasee M. Jeewandara

    2014-01-01

    Full Text Available Cardiovascular disease is the dominant cause of mortality in developed countries, with coronary artery disease (CAD a predominant contributor. The development of stents to treat CAD was a significant innovation, facilitating effective percutaneous coronary revascularization. Coronary stents have evolved from bare metal compositions, to incorporate advances in pharmacological therapy in what are now known as drug eluting stents (DES. Deployment of a stent overcomes some limitations of balloon angioplasty alone, but provides an acute stimulus for thrombus formation and promotes neointimal hyperplasia. First generation DES effectively reduced in-stent restenosis, but profoundly delay healing and are susceptible to late stent thrombosis, leading to significant clinical complications in the long term. This review characterizes the development of coronary stents, detailing the incremental improvements, which aim to attenuate the major clinical complications of thrombosis and restenosis. Despite these enhancements, coronary stents remain fundamentally incompatible with the vasculature, an issue which has largely gone unaddressed. We highlight the latest modifications and research directions that promise to more holistically design coronary implants that are truly biocompatible.

  18. [How do I assess requirement of a blood bank and its kind for a healthcare establishment?].

    Science.gov (United States)

    Lafeuillade, B; Tixier, A; Bliem, C; Meyer, F

    2014-12-01

    Access to blood components is required for healthcare establishments, particularly for emergency situation and hospital blood bank was often a response to this requirement. However, the complexity of regulation and economic pressures lead healthcare establishment to review regularly their need for a blood bank. This assessment requires analysis of need for transfusions in terms of delay, quantity and clinical situations to which they must respond. When a blood bank is required, three kinds could be under consideration: emergency blood bank, intermediate blood bank and issuance blood bank. According to requirements, advantages and disadvantages of each kind, healthcare establishments would select the most suitable one.

  19. Hemocompatibility and biocompatibility of antibacterial biomimetic hybrid films

    Energy Technology Data Exchange (ETDEWEB)

    Coll Ferrer, M. Carme [Department of Anesthesiology and Critical Care, University of Pennsylvania, Philadelphia, PA 19104 (United States); Department of Materials Science and Engineering, University of Pennsylvania, Philadelphia, PA 19104 (United States); Eckmann, Uriel N. [Department of Anesthesiology and Critical Care, University of Pennsylvania, Philadelphia, PA 19104 (United States); Composto, Russell J. [Department of Materials Science and Engineering, University of Pennsylvania, Philadelphia, PA 19104 (United States); Eckmann, David M., E-mail: eckmanndm@uphs.upenn.edu [Department of Anesthesiology and Critical Care, University of Pennsylvania, Philadelphia, PA 19104 (United States)

    2013-11-01

    In previous work, we developed novel antibacterial hybrid coatings based on dextran containing dispersed Ag NPs (∼ 5 nm, DEX-Ag) aimed to offer dual protection against two of the most common complications associated with implant surgery, infections and rejection of the implant. However, their blood-material interactions are unknown. In this study, we assess the hemocompatibility and biocompatibility of DEX-Ag using fresh blood and two cell lines of the immune system, monocytes (THP-1 cells) and macrophages (PMA-stimulated THP-1 cells). Glass, polyurethane (PU) and bare dextran (DEX) were used as reference surfaces. PU, DEX and DEX-Ag exhibited non-hemolytic properties. Relative to glass (100%), platelet attachment on PU, DEX and DEX-Ag was 15%, 10% and 34%, respectively. Further, we assessed cell morphology and viability, pro-inflammatory cytokines expression (TNF-α and IL-1β), pro-inflammatory eicosanoid expression (Prostaglandin E{sub 2}, PGE{sub 2}) and release of reactive oxygen species (ROS, superoxide and H{sub 2}O{sub 2}) following incubation of the cells with the surfaces. The morphology and cell viability of THP-1 cells were not affected by DEX-Ag whereas DEX-Ag minimized spreading of PMA-stimulated THP-1 cells and caused a reduction in cell viability (16% relative to other surfaces). Although DEX-Ag slightly enhanced release of ROS, the expression of pro-inflammatory cytokines remained minimal with similar levels of PGE{sub 2}, as compared to the other surfaces studied. These results highlight low toxicity of DEX-Ag and hold promise for future applications in vivo. - Highlights: • We examined specific blood-contact reactions of dextran doped with Ag NPs coatings. • Biocompatibility was assessed with THP-1 cells and PMA-stimulated THP-1 cells. • Glass, polyurethane and dextran were used as reference surfaces. • Hybrid coatings exhibited non-hemolytic properties. • Low toxicity, inflammatory response and ROS suggest potential for in vivo use.

  20. Blood Pressure and Global Risk Assessment in a Swedish Population

    OpenAIRE

    Jenny Eckner; Larsson, Charlotte A.; Lennart Råstam; Ulf Lindblad

    2012-01-01

    This study investigated the association between SCORE and the 2007 ESH-ESC blood pressure categories and explored achievements of blood pressure goals considering global risk. In 2001–2005, a random sample of inhabitants aged 30–74 years in southwestern Sweden was invited to a survey of cardiovascular risk factors. The study enrolled 2816 participants (participation rate 76%). Blood pressure was categorized according to the 2007 ESH-ESC guidelines. Global risk of 10-year CVD death was estimat...

  1. A Suprachoroidal Electrical Retinal Stimulator Design for Long-Term Animal Experiments and In Vivo Assessment of Its Feasibility and Biocompatibility in Rabbits

    Directory of Open Access Journals (Sweden)

    J. A. Zhou

    2008-01-01

    Full Text Available This article reports on a retinal stimulation system for long-term use in animal electrical stimulation experiments. The presented system consisted of an implantable stimulator which provided continuous electrical stimulation, and an external component which provided preset stimulation patterns and power to the implanted stimulator via a paired radio frequency (RF coil. A rechargeable internal battery and a parameter memory component were introduced to the implanted retinal stimulator. As a result, the external component was not necessary during the stimulation mode. The inductive coil pair was used to pass the parameter data and to recharge the battery. A switch circuit was used to separate the stimulation mode from the battery recharging mode. The implantable stimulator was implemented with IC chips and the electronics, except for the stimulation electrodes, were hermetically packaged in a biocompatible metal case. A polyimide-based gold electrode array was used. Surgical implantation into rabbits was performed to verify the functionality and safety of this newly designed system. The electrodes were implanted in the suprachoroidal space. Evoked cortical potentials were recorded during electrical stimulation of the retina. Long-term follow-up using OCT showed no chorioretinal abnormality after implantation of the electrodes.

  2. A suprachoroidal electrical retinal stimulator design for long-term animal experiments and in vivo assessment of its feasibility and biocompatibility in rabbits.

    Science.gov (United States)

    Zhou, J A; Woo, S J; Park, S I; Kim, E T; Seo, J M; Chung, H; Kim, S J

    2008-01-01

    This article reports on a retinal stimulation system for long-term use in animal electrical stimulation experiments. The presented system consisted of an implantable stimulator which provided continuous electrical stimulation, and an external component which provided preset stimulation patterns and power to the implanted stimulator via a paired radio frequency (RF) coil. A rechargeable internal battery and a parameter memory component were introduced to the implanted retinal stimulator. As a result, the external component was not necessary during the stimulation mode. The inductive coil pair was used to pass the parameter data and to recharge the battery. A switch circuit was used to separate the stimulation mode from the battery recharging mode. The implantable stimulator was implemented with IC chips and the electronics, except for the stimulation electrodes, were hermetically packaged in a biocompatible metal case. A polyimide-based gold electrode array was used. Surgical implantation into rabbits was performed to verify the functionality and safety of this newly designed system. The electrodes were implanted in the suprachoroidal space. Evoked cortical potentials were recorded during electrical stimulation of the retina. Long-term follow-up using OCT showed no chorioretinal abnormality after implantation of the electrodes.

  3. Biocompatible 3D printed magnetic micro needles

    KAUST Repository

    Kavaldzhiev, Mincho

    2017-01-30

    Biocompatible functional materials play a significant role in drug delivery, tissue engineering and single cell analysis. We utilized 3D printing to produce high aspect ratio polymer resist microneedles on a silicon substrate and functionalized them by iron coating. Two-photon polymerization lithography has been used for printing cylindrical, pyramidal, and conical needles from a drop cast IP-DIP resist. Experiments with cells were conducted with cylindrical microneedles with 630 ± 15 nm in diameter with an aspect ratio of 1:10 and pitch of 12 μm. The needles have been arranged in square shaped arrays with various dimensions. The iron coating of the needles was 120 ± 15 nm thick and has isotropic magnetic behavior. The chemical composition and oxidation state were determined using energy electron loss spectroscopy, revealing a mixture of iron and Fe3O4 clusters. A biocompatibility assessment was performed through fluorescence microscopy using calcein/EthD-1 live/dead assay. The results show a very high biocompatibility of the iron coated needle arrays. This study provides a strategy to obtain electromagnetically functional microneedles that benefit from the flexibility in terms of geometry and shape of 3D printing. Potential applications are in areas like tissue engineering, single cell analysis or drug delivery.

  4. Eicosanoid release as laboratory indicator of biocompatibility.

    Science.gov (United States)

    Mahiout, A; Jörres, A; Schultze, G; Meinhold, H; Kessel, M

    1989-06-01

    Biocompatibility evaluation of extracorporeal devices requires the establishment of sensitive indicators of blood cells/surface interactions. Among others, arachidonic acid derivatives, such as prostaglandins and thromboxanes, play an important role in the cell control systems. Hence, the release of eicosanoids during blood exposure to dialyzer membranes was investigated. Experiments included in vitro incubation of human blood with flat membranes (FM), as well as ex vivo perfusion of hollow fiber membranes (HFM) with blood from healthy volunteers in single-pass fashion. In both models, a significant release of prostaglandin E2 (PGE2) and thromboxane B2 (TXB2) was detected. In addition, the amount of eicosanoid release depended on the type of membrane tested. After a 10-min FM incubation with fresh blood, plasma concentrations of TXB2 and PGE2 were pronounced by polycarbonate when compared to Cuprophan and polyacrylonitrile. During 10 min of open loop perfusion of HFM, polymethylmethacrylate was the most active biomaterial, whereas the reactivity of Cuprophan was significantly lower. Among HFM, Hemophan was by far the less active. These results indicate that the release of eicosanoids represents a sensitive parameter of blood cells/membrane reactivity. Thus, the question arises as to whether or not the extracorporeal process of cyclooxygenase activity could contribute to the clinical side effects of chronical hemodialysis.

  5. Blood: Tests Used to Assess the Physiological and Immunological Properties of Blood

    Science.gov (United States)

    Quinn, J. G.; Tansey, E. A.; Johnson, C. D.; Roe, S. M.; Montgomery, L. E. A.

    2016-01-01

    The properties of blood and the relative ease of access to which it can be retrieved make it an ideal source to gauge different aspects of homeostasis within an individual, form an accurate diagnosis, and formulate an appropriate treatment regime. Tests used to determine blood parameters such as the erythrocyte sedimentation rate, hemoglobin…

  6. The Lectin Pathway of Complement and Biocompatibility

    DEFF Research Database (Denmark)

    Hein, Estrid; Garred, Peter

    2015-01-01

    In modern health technologies the use of biomaterials in the form of stents, haemodialysis tubes, artificial implants, bypass circuits etc. is rapidly expanding. The exposure of synthetic, foreign surfaces to the blood and tissue of the host, calls for strict biocompatibility in respect to contac...... been broadly documented. However, the specific role of lectin pathway and the pattern recognition molecules initiating the pathway has only been transiently investigated. Here we review the current data on the field....... activation, the coagulation system and the complement system. The complement system is an important part of the initial immune response and consists of fluid phase molecules in the blood stream. Three different activation pathways can initiate the complement system, the lectin, the classical...

  7. Home readings of blood pressure in assessment of hypertensive subjects

    DEFF Research Database (Denmark)

    Nielsen, P.E.; Myschetzky, P; Andersen, A R

    1986-01-01

    Out-patient clinic blood pressure (OPC-BP) was compared to home blood pressure (Home-BP) measured three times daily during a two week period in 122 consecutively referred hypertensive subjects. A semi-automatic device (TM-101) including a microphone for detection of Korotkoff-sounds, self......-deflation of cuff pressure and digital display of blood pressure was used. Mean difference between OPC-BP and Home-BP was systolic +13 mm Hg (range -21 - +100 mg Hg) and diastolic +5 mm Hg (range -27 - +36 mm Hg). Although a significant correlation could be demonstrated between Home-BP and OPC-BP, the inter...

  8. Effects of surface finishing conditions on the biocompatibility of a nickel-chromium dental casting alloy.

    LENUS (Irish Health Repository)

    McGinley, Emma Louise

    2011-07-01

    To assess the effects of surface finishing condition (polished or alumina particle air abraded) on the biocompatibility of direct and indirect exposure to a nickel-chromium (Ni-Cr) d.Sign®10 dental casting alloy on oral keratinocytes. Biocompatibility was performed by assessing cellular viability and morphology, metabolic activity, cellular toxicity and presence of inflammatory cytokine markers.

  9. Assessment of glycaemic, lipid and blood pressure control among ...

    African Journals Online (AJOL)

    Diabetes mellitus (DM) is a metabolic disorder primarily characterized by elevated blood glucose levels and microvascular andmacrovascular complications. ... are needed to reduce the likelihood of development of macrovascular disease.

  10. Synthetic cornea: biocompatibility and optics

    Science.gov (United States)

    Parel, Jean-Marie A.; Kaminski, Stefan; Fernandez, Viviana; Alfonso, E.; Lamar, Peggy; Lacombe, Emmanuel; Duchesne, Bernard; Dubovy, Sander; Manns, Fabrice; Rol, Pascal O.

    2002-06-01

    Purpose. Experimentally find a method to provide a safe surgical technique and an inexpensive and long lasting mesoplant for the restoration of vision in patients with bilateral corneal blindness due to ocular surface and stromal diseases. Methods. Identify the least invasive and the safest surgical technique for synthetic cornea implantation. Identify the most compatible biomaterials and the optimal shape a synthetic cornea must have to last a long time when implanted in vivo. Results. Penetrating procedures were deemed too invasive, time consuming, difficult and prone to long term complications. Therefore a non-penetrating delamination technique with central trephination was developed to preserve the integrity of Descemet's membrane and the anterior segment. Even though this approach limits the number of indications, it is acceptable since the majority of patients only have opacities in the stroma. The prosthesis was designed to fit in the removed tissue plane with its skirt fitted under the delaminated stroma. To improve retention, the trephination wall was made conical with the smallest opening on the anterior surface and a hat-shaped mesoplant was made to fit. The skirt was perforated in its perimeter to allow passage of nutrients and tissues ingrowths. To simplify the fabrication procedure, the haptic and optic were made of the same polymer. The intrastromal biocompatibility of several hydrogels was found superior to current clinically used PMMA and PTFE materials. Monobloc mesoplants made of 4 different materials were implanted in rabbits and followed weekly until extrusion occurred. Some remained optically clear allowing for fundus photography. Conclusions. Hydrogel synthetic corneas can be made to survive for periods longer than 1 year. ArF excimer laser photoablation studies are needed to determine the refractive correction potential of these mesoplants. A pilot FDA clinical trial is needed to assess the mesoplant efficacy and very long-term stability.

  11. Blood

    Science.gov (United States)

    ... Also, blood is either Rh-positive or Rh-negative. So if you have type A blood, it's either A positive or A negative. Which type you are is important if you need a blood transfusion. And your Rh factor could be important ...

  12. Using ambulatory blood pressure monitoring to assess blood pressure of firefighters with parental history of hypertension.

    Science.gov (United States)

    de Mattos, Carlos Eduardo; de Mattos, Marco Antonio; Toledo, Daniele Gusmão; de Siqueira Filho, Aristarco Gonçalves

    2006-12-01

    To evaluate the influence of family history of systemic arterial hypertension (FSAH) on the effect of stress from work in Uniformed Firefighters (BMCs) through Ambulatory Blood Pressure Monitoring (ABPM). A prospective case-control study. Sixty-six healthy BMC underwent ABPM during 12 hours of work at the Communication Center (CC). Thirty-four had hypertensive parents (group 1) and thirty-two had normotensive parents (group 2). Group I differed from group 2 in that it showed higher mean systolic (134.1 +/- 9.9 mmHg X 120.8 +/- 9.9 mmHg p pressure, in addition to greater systolic (31.4 +/- 25.6 % X 9.4 +/- 9.4 % p = 0.0001) and diastolic (28.3 +/- 26.6 % X 6.1 +/- 8.9 % p = 0.0001) loads. The prevalence of systemic arterial hypertension (SAH) in group 1 at the workplace was 32.3%. Monitored away from the job, these subjects showed normal blood pressure (functionally hypertensive). Group 2 revealed normal blood pressure (BP) at work. Higher blood pressure in BMC with hypertensive parents is explained independently by the SAH. Subjects who developed SAH during their work at the CC may be considered functionally hypertensive, whereas those with normotensive parents and who underwent psychological stress are free of blood pressure changes.

  13. Assessing the influence of mechanical ventilation on blood gases and blood pressure in rattlesnakes

    DEFF Research Database (Denmark)

    Bertelsen, Mads F.; Buchanan, Rasmus; Jensen, Heidi M.

    2015-01-01

    OBJECTIVE: To characterize the impact of mechanical positive pressure ventilation on heart rate (HR), arterial blood pressure, blood gases, lactate, glucose, sodium, potassium and calcium concentrations in rattlesnakes during anesthesia and the subsequent recovery period. STUDY DESIGN: Prospective...... ventilation at a tidal volume of 30 mL kg(-1) at 1 breath every 90 seconds, 5 breaths minute(-1) , or 15 breaths minute(-1) . Arterial blood was collected from indwelling catheters at 30, 40, and 60 minutes and 2, 6, and 24 hours following induction of anesthesia and analyzed for pH, PaO2 , PaCO2...... , and selected variables. Mean arterial blood pressure (MAP) and HR were recorded at 30, 40, 60 minutes and 24 hours. RESULTS: Spontaneous ventilation and 1 breath every 90 seconds resulted in a mild hypercapnia (PaCO2 22.4 ± 4.3 mmHg [3.0 ± 0.6 kPa] and 24.5 ± 1.6 mmHg [3.3 ± 0.2 kPa], respectively), 5 breaths...

  14. The Blood Compatibilities of Blood Purification Membranes and Other Materials Developed in Japan

    OpenAIRE

    Takaya Abe; Karen Kato; Tomoaki Fujioka; Tadao Akizawa

    2011-01-01

    The biocompatibilities in blood purification therapy are defined as “a concept to stipulate safety of blood purification therapy by an index based on interaction in the body arising from blood purification therapy itself.” The biocompatibilities are associated with not only materials to be used but also many factors such as sterilization method and eluted substance. It is often evaluated based on impacts on cellular pathways and on humoral pathways. Since the biocompatibilities of blood purif...

  15. Biocompatibility of Bletilla striata Microspheres as a Novel Embolic Agent

    Directory of Open Access Journals (Sweden)

    ShiHua Luo

    2015-01-01

    Full Text Available We have prepared Chinese traditional herb Bletilla striata into microspheres as a novel embolic agent for decades. The aim of this study was to evaluate the biocompatibility of Bletilla striata microspheres (BSMs. After a thermal test of BSMs in vitro, the cell biocompatibility of BSMs was investigated in mouse fibroblasts and human umbilical vein endothelial cells using the methyl tetrazolium (MTT assay. In addition, blood biocompatibility was evaluated. In vivo intramuscular implantation and renal artery embolization in rabbits with BSMs were used to examine the inflammatory response. The experimental rabbits did not develop any fever symptoms after injection of BSMs, and BSMs exhibited no cytotoxicity in cultured mouse fibroblasts and human umbilical vein endothelial cells. Additionally, BSMs exhibited high compatibility with red blood cells and no hemolysis activity. Intramuscular implantation with BSMs resulted in a gradually lessened mild inflammatory reaction that disappeared after eight weeks. The occlusion of small renal vessels was associated with a mild perivascular inflammatory reaction without significant renal and liver function damage. In conclusion, we believe that BSMs exhibit high biocompatibility and are a promising embolic agent.

  16. Biocompatibility of Bletilla striata Microspheres as a Novel Embolic Agent.

    Science.gov (United States)

    Luo, ShiHua; Song, SongLin; Zheng, ChuanSheng; Wang, Yong; Xia, XiangWen; Liang, Bin; Feng, GanSheng

    2015-01-01

    We have prepared Chinese traditional herb Bletilla striata into microspheres as a novel embolic agent for decades. The aim of this study was to evaluate the biocompatibility of Bletilla striata microspheres (BSMs). After a thermal test of BSMs in vitro, the cell biocompatibility of BSMs was investigated in mouse fibroblasts and human umbilical vein endothelial cells using the methyl tetrazolium (MTT) assay. In addition, blood biocompatibility was evaluated. In vivo intramuscular implantation and renal artery embolization in rabbits with BSMs were used to examine the inflammatory response. The experimental rabbits did not develop any fever symptoms after injection of BSMs, and BSMs exhibited no cytotoxicity in cultured mouse fibroblasts and human umbilical vein endothelial cells. Additionally, BSMs exhibited high compatibility with red blood cells and no hemolysis activity. Intramuscular implantation with BSMs resulted in a gradually lessened mild inflammatory reaction that disappeared after eight weeks. The occlusion of small renal vessels was associated with a mild perivascular inflammatory reaction without significant renal and liver function damage. In conclusion, we believe that BSMs exhibit high biocompatibility and are a promising embolic agent.

  17. Adhesion of biocompatible and biodegradable micropatterned surfaces

    NARCIS (Netherlands)

    Kaiser, J.S.; Kamperman, M.M.G.; Souza, E.J.; Schick, B.; Arzt, E.

    2011-01-01

    We studied the effects of pillar dimensions and stiffness of biocompatible and biodegradable micropatterned surfaces on adhesion on different compliant substrates. The micropatterned adhesives were based on biocompatible polydimethylsiloxane (PDMS) and biodegradable poly(lactic-co-glycolic) acid (PL

  18. Stretchable biocompatible electronics by embedding electrical circuitry in biocompatible elastomers.

    Science.gov (United States)

    Jahanshahi, Amir; Salvo, Pietro; Vanfleteren, Jan

    2012-01-01

    Stretchable and curvilinear electronics has been used recently for the fabrication of micro systems interacting with the human body. The applications range from different kinds of implantable sensors inside the body to conformable electrodes and artificial skins. One of the key parameters in biocompatible stretchable electronics is the fabrication of reliable electrical interconnects. Although very recent literature has reported on the reliability of stretchable interconnects by cyclic loading, work still needs to be done on the integration of electrical circuitry composed of rigid components and stretchable interconnects in a biological environment. In this work, the feasibility of a developed technology to fabricate simple electrical circuits with meander shaped stretchable interconnects is presented. Stretchable interconnects are 200 nm thin Au layer supported with polyimide (PI). A stretchable array of light emitting diodes (LEDs) is embedded in biocompatible elastomer using this technology platform and it features a 50% total elongation.

  19. An estimate of the prevalence of biocompatible and habitable planets.

    Science.gov (United States)

    Fogg, M J

    1992-01-01

    A Monte Carlo computer model of extra-solar planetary formation and evolution, which includes the planetary geochemical carbon cycle, is presented. The results of a run of one million galactic disc stars are shown where the aim was to assess the possible abundance of both biocompatible and habitable planets. (Biocompatible planets are defined as worlds where the long-term presence of surface liquid water provides environmental conditions suitable for the origin and evolution of life. Habitable planets are those worlds with more specifically Earthlike conditions). The model gives an estimate of 1 biocompatible planet per 39 stars, with the subset of habitable planets being much rarer at 1 such planet per 413 stars. The nearest biocompatible planet may thus lie approximately 14 LY distant and the nearest habitable planet approximately 31 LY away. If planets form in multiple star systems then the above planet/star ratios may be more than doubled. By applying the results to stars in the solar neighbourhood, it is possible to identify 28 stars at distances of < 22 LY with a non-zero probability of possessing a biocompatible planet.

  20. Biocompatible polysaccharide-based cryogels

    Energy Technology Data Exchange (ETDEWEB)

    Reichelt, Senta, E-mail: senta.reichelt@iom-leipzig.de [Leibniz Institute of Surface Modification, Permoserstr. 15, 04318 Leipzig (Germany); Becher, Jana; Weisser, Jürgen [Innovent e.V., Pruessingstr. 27B, 07745 Jena (Germany); Prager, Andrea; Decker, Ulrich [Leibniz Institute of Surface Modification, Permoserstr. 15, 04318 Leipzig (Germany); Möller, Stephanie; Berg, Albrecht; Schnabelrauch, Matthias [Innovent e.V., Pruessingstr. 27B, 07745 Jena (Germany)

    2014-02-01

    This study focuses on the development of novel biocompatible macroporous cryogels by electron-beam assisted free-radical crosslinking reaction of polymerizable dextran and hyaluronan derivatives. As a main advantage this straightforward approach provides highly pure materials of high porosity without using additional crosslinkers or initiators. The cryogels were characterized with regard to their morphology and their basic properties including thermal and mechanical characteristics, and swellability. It was found that the applied irradiation dose and the chemical composition strongly influence the material properties of the resulting cryogels. Preliminary cytotoxicity tests illustrate the excellent in vitro-cytocompatibility of the fabricated cryogels making them especially attractive as matrices in tissue regeneration procedures. - Graphical abstract: Electron-beam initiated synthesis of biocompatible cryogels based on natural polymers. - Highlights: • Successful electron-beam induced synthesis of dextran and hyaluronan cryogels. • Mechanical and thermal stable cryogels were obtained. • Excellent cytocompatibility of the materials was proven. • Promising materials for tissue engineering were developed.

  1. In vitro biocompatibility testing of some synthetic polymers used for the achievement of nervous conduits.

    Science.gov (United States)

    Mihai, R; Florescu, I P; Coroiu, V; Oancea, A; Lungu, M

    2011-08-15

    Biocompatible synthetic polymers are largely used in the bio-medical domain, tissue engineering and in controlled release of medicines. Polymers can be used in the achievement of cardiac and vascular devices, mammary implants, eye lenses, surgical threads, nervous conduits, adhesives, blood substitutes, etc. Our study was axed on the development of cytotoxicity tests for 3 synthetic polymers, namely polyvinyl alcohol, polyethylene glycol and polyvinyl chloride. These tests targeted to determine the viability and morphology of cells (fibroblasts) that were in indirect contact with the studied polymers. Cell viability achieved for all the studied synthetic polymers allowed their frame in biocompatible material category. Cell morphology did not significantly change, thus accomplishing a new biocompatibility criterion. The degree of biocompatibility of the studied polymers varied. Polyvinyl alcohol presented the highest grade of biocompatibility and polyvinyl chloride placed itself at the lowest limit of biocompatibility. The results achieved allowed the selection of those polymers that (by enhancing their degrees of biocompatibility due to the association with various biopolymers) will be used in the development of new biocompatible materials, useful in nervous conduits manufacture.

  2. Biocompatible and Bioeliminable Hydrophilic Polymers

    Institute of Scientific and Technical Information of China (English)

    Paolo; FerrutiUniversità

    2007-01-01

    1 Introduction This presentation will report on some recent results obtained in Milan on two polymer families of biomedical interest, namely poly(N-vinyl-2-pyrrolidinone) and polyamidoamines. 2 Results and DiscussionPoly(N-vinyl-2-pyrrolidinone) (PVP) is a well known bioactive and biocompatible polymer. In its soluble form, it is largely used as excipient of oral pharmaceutical formulations, especially for its high water solubilising power.In its crosslinked form, it plays a relevant role as biomateria...

  3. Doppler Assessment of Uterine Blood Flow in Recurrent Pregnancy Loss

    Directory of Open Access Journals (Sweden)

    Maryam Barzin

    2011-05-01

    Full Text Available Recurrent spontaneous abortion affects 2%-5% of"ncouples. Uterine perfusion is considered as one of the"nfactors that influences the success of implantation."nDuring the normal menstrual cycle, the impedance"nto uterine artery blood flow diminishes progressively"nduring the luteal phase, reaching the lowest values"nin the period coinciding with the implantation time."nImpedance of uterine arteries is a good indicator of"nthe possibility of a subsequent pregnancy. High blood"nflow resistance is associated with a reduced conception"nrate and women with lower pulsatility index values"nhave the highest possibility of becoming pregnant. An"nimpaired uterine perfusion could play a major role in"nthe pathogenesis of recurrent spontaneous abortion. In"nthis study, we examined sixty women with recurrent"nspontaneous abortion and a control group including"nthirty normal women with at least one previous"nuncomplicated pregnancy and without history of any"nabortion. Transvaginal sonography associated with"nDoppler flow measurement was performed during"nthe midluteal phase of a cycle in all women. The"nmeasurement of the ascending branch of both right"nand left uterine arteries was taken lateral to the cervix"nat the level of the internal os. The pulsatility and"nresistance index of both uterine arteries were calculated"nand compared in both groups. In this presentation we"nreport our finding in two groups. We also explain the"nexact method of study and present some interesting"ncases

  4. Whole blood treated with riboflavin and ultraviolet light: quality assessment of all blood components produced by the buffy coat method.

    Science.gov (United States)

    Schubert, Peter; Culibrk, Brankica; Karwal, Simrath; Serrano, Katherine; Levin, Elena; Bu, Daniel; Bhakta, Varsha; Sheffield, William P; Goodrich, Raymond P; Devine, Dana V

    2015-04-01

    Pathogen inactivation (PI) technologies are currently licensed for use with platelet (PLT) and plasma components. Treatment of whole blood (WB) would be of benefit to the blood banking community by saving time and costs compared to individual component treatment. However, no paired, pool-and-split study directly assessing the impact of WB PI on the subsequently produced components has yet been reported. In a "pool-and-split" study, WB either was treated with riboflavin and ultraviolet (UV) light or was kept untreated as control. The buffy coat (BC) method produced plasma, PLT, and red blood cell (RBC) components. PLT units arising from the untreated WB study arm were treated with riboflavin and UV light on day of production and compared to PLT concentrates (PCs) produced from the treated WB units. A panel of common in vitro variables for the three types of components was used to monitor quality throughout their respective storage periods. PCs derived from the WB PI treatment were of significantly better quality than treated PLT components for most variables. RBCs produced from the WB treatment deteriorated earlier during storage than untreated units. Plasma components showed a 3% to 44% loss in activity for several clotting factors. Treatment of WB with riboflavin and UV before production of components by the BC method shows a negative impact on all three blood components. PLT units produced from PI-treated WB exhibited less damage compared to PLT component treatment. © 2014 AABB.

  5. Biocompatible Peritoneal Dialysis Fluids: Clinical Outcomes

    Directory of Open Access Journals (Sweden)

    Yeoungjee Cho

    2012-01-01

    Full Text Available Peritoneal dialysis (PD is a preferred home dialysis modality and has a number of added advantages including improved initial patient survival and cost effectiveness over haemodialysis. Despite these benefits, uptake of PD remains relatively low, especially in developed countries. Wider implementation of PD is compromised by higher technique failure from infections (e.g., PD peritonitis and ultrafiltration failure. These are inevitable consequences of peritoneal injury, which is thought to result primarily from continuous exposure to PD fluids that are characterised by their “unphysiologic” composition. In order to overcome these barriers, a number of more biocompatible PD fluids, with neutral pH, low glucose degradation product content, and bicarbonate buffer have been manufactured over the past two decades. Several preclinical studies have demonstrated their benefit in terms of improvement in host cell defence, peritoneal membrane integrity, and cytokine profile. This paper aims to review randomised controlled trials assessing the use of biocompatible PD fluids and their effect on clinical outcomes.

  6. CARDIOVASCULAR RISK ASSESSMENT AND SUPPORT TECHNIQUES Whole blood viscosity assessment issues I: Extrapolation chart and reference values

    Directory of Open Access Journals (Sweden)

    Ezekiel Uba Nwose

    2010-04-01

    Full Text Available Background: There are many different methods for the assessment of whole blood viscosity, but not every pathology unit has equipment for any of the methods. However, a validated arithmetic method exists whereby whole blood viscosity can be extrapolated from haematocrit and total serum proteins. Aims: The objective of this work is to develop an algorithm in the form of a chart by which clinicians can easily extrapolate whole blood viscosity values in their consulting rooms or on the ward. Another objective is to suggest normal, subnormal and critical reference ranges applicable to this method. Materials and Methods: Whole blood viscosity at high shear stress was determined, from various possible pairs of haematocrit and total proteins. A chart was formulated so that whole blood viscosity can be extrapolated. After determination of two standard deviations from the mean and ascertainment of symmetric distribution, normal and abnormal reference ranges were defined. Results: The clinicians’ user-friendly chart is presented. Considering presumptive lower and upper limits, the continuum of ≤14.28, 14.29 – 15.00, 15.01 – 19.01, 19.02 – 19.39 and ≥19.40 (208 Sec-1 is obtained as reference ranges for critically low, subnormal low, normal, subnormal high and critically high whole blood viscosity levels respectively. Conclusion: This article advances a validated method to provide a user-friendly chart that would enable clinicians to assess whole blood viscosity for any patients who has results for full blood count and total proteins. It would make the assessment of whole blood viscosity costless and the neglect of a known cardiovascular risk factor less excusable.

  7. Assessing the association of severe malaria infection and ABO blood groups in northwestern Ethiopia.

    Science.gov (United States)

    Tadesse, Hailu; Tadesse, Kebede

    2013-12-01

    There is lack of adequate information on the association between severe malaria and some human genetic markers like ABO blood types. The study was undertaken to evaluate the association between severe malaria infection and ABO blood types among febrile patients attending Felegeselam Health Center, northwestern Ethiopia. A total of 398 febrile patients were examined for malaria and tested for ABO blood groups in December 2011. The blood samples were collected by finger pricking, stained with Giemsa and slides were examined microscopically. ABO blood group was determined by agglutination test using agglutinating A and B monoclonal anti-sera together with parasite load count. Chi-square and ANOVA tests were used to assess the difference between frequencies and means, respectively. Out of 398 acute febrile patients, 201 (50.5%) were found to be infected with Plasmodium parasites. Of which 194 (48.74%) and 7 (1.76%) belong to Plasmodium falciparum and P. vivax, respectively. The distribution of ABO blood groups was O (46%), A (27.1%), B (23.1%) and AB (3.8%). The percentage of severe malaria with respect to blood group A, B, AB and O was found to be 40, 34.1, 14.3 and 5.1%, respectively. The association of severe malaria with non 'O' blood types was statistically significant (χ2 = 31.246, p <0.01). The present findings indicate that individuals with blood groups A, B and AB are more susceptible for severe malaria infection than blood group O.

  8. Biocompatibility studies of polyacrylonitrile membranes modified with carboxylated polyetherimide

    Energy Technology Data Exchange (ETDEWEB)

    Senthilkumar, S.; Rajesh, S.; Jayalakshmi, A.; Mohan, D., E-mail: mohantarun@gmail.com

    2013-10-15

    Poly (ether-imide) (PEI) was carboxylated and used as the hydrophilic modification agent for the preparation of polyacrylonitrile (PAN) membranes. Membranes were prepared with different blend compositions of PAN and CPEI by diffusion induced precipitation. The modified membranes were characterized by thermo gravimetric analysis (TGA), mechanical analysis, scanning electron microscopy (SEM) and contact angle measurement to understand the influence of CPEI on the properties of the membranes. The biocompatibility studies exhibited reduced plasma protein adsorption, platelet adhesion and thrombus formation on the modified membrane surface. The complete blood count (CBC) results of CPEI incorporated membranes showed stable CBC values and significant decrease in the complement activation were also observed. In addition to good cytocompatibility, monocytes cultured on these modified membranes exhibited improved functional profiles in 3-(4, 5-dimethylthiazol-2-yl)-2, 5-diphenyl tetrazolium bromide (MTT) assay. Thus it could be concluded that PAN/CPEI membranes with excellent biocompatibility can be useful for hemodialysis. Highlights: • Carboxylated PEI was prepared and utilized as hydrophilic modification agent. • CPEI incorporated into PAN to improved biocompatibility and cyto compatibility • Biocompatibility of membranes was correlated with morphology and hydrophilicity. • Antifouling studies of the PAN/CPEI membranes was studied by BSA as model foulant.

  9. Contrast sensitivity, ocular blood flow and their potential role in assessing ischaemic retinal disease.

    Science.gov (United States)

    Shoshani, Yochai Z; Harris, Alon; Rusia, Deepam; Spaeth, George L; Siesky, Brent; Pollack, Ayala; Wirostko, Barbara

    2011-08-01

    To examine the definition, evaluation methodology, association to ocular blood flow and potential clinical value of contrast sensitivity (CS) testing in clinical and research settings, focusing in patients with ischemic retinal disease. A review of the medical literature focusing on CS and ocular blood flow in ischemic retinal disease. CS may be more sensitive than other methods at detecting subtle defects or improvements in primarily central retinal ganglion cell function early on in a disease process. CS testing attempts to provide spatial detection differences which are not directly assessed with standard visual acuity chart testing. Analyzing all studies that have assessed both CS change and ocular blood flow, it is apparent that both choroidal circulation and retinal circulation may have an important role in influencing CS. The concept that CS is directly influenced by ocular blood flow is supported by reviewing the studies involving both. Although the studies in the literature have not established a direct cause and effect relationship per se, the literature review makes it logical to assume that changes in retinal and choroidal blood flow influence CS. This raises the possibility that a subjective visual characteristic, specifically CS, may be able to be evaluated more objectively by studying blood flow. It appears appropriate to study the relationship between blood flow and CS more extensively to develop improved ways of measuring various aspects of blood flow to the eye and to best quantify early changes in visual function. © 2011 The Authors. Acta Ophthalmologica © 2011 Acta Ophthalmologica Scandinavica Foundation.

  10. An assessment of various blood collection and transfer methods used for malaria rapid diagnostic tests

    Directory of Open Access Journals (Sweden)

    Baik Fred

    2007-11-01

    Full Text Available Abstract Background Four blood collection and transfer devices commonly used for malaria rapid diagnostic tests (RDTs were assessed for their consistency, accuracy and ease of use in the hands of laboratory technicians and village health workers. Methods Laboratory technicians and village health workers collected blood from a finger prick using each device in random order, and deposited the blood either on filter paper or into a suitable casette-type RDT. Consistency and accuracy of volume delivered was determined by comparing the measurements of the resulting blood spots/heights with the measurements of laboratory-prepared pipetted standard volumes. The effect of varying blood volumes on RDT sensitivity and ease of use was also observed. Results There was high variability in blood volume collected by the devices, with the straw and the loop, the most preferred devices, usually transferring volumes greater than intended, while the glass capillary tube and the plastic pipette transferring less volume than intended or none at all. Varying the blood volume delivered to RDTs indicated that this variation is critical to RDT sensitivity only when the transferred volume is very low. Conclusion None of the blood transfer devices assessed performed consistently well. Adequate training on their use is clearly necessary, with more development efforts for improved designs to be used by remote health workers, in mind.

  11. Glucometer as a chairside device to assess blood glucose in periodontal patients

    Directory of Open Access Journals (Sweden)

    G N Bala Raghavendra

    2010-01-01

    Full Text Available Background: Diabetes mellitus is a common finding in the medical history of patients receiving treatment for periodontal disease. The incidence of diabetes is on the rise worldwide. Virtually, every dentist and especially the periodontist are likely to encounter an increasing number of undiagnosed diabetic patients. The conventional laboratory methods employed to detect blood glucose are time consuming and require elaborative equipment. The advent of blood glucose monitors allows the clinician to assess blood glucose at the chair side. Materials and Methods: The use of gingival capillary blood as a marker for blood glucose estimation using glucometer against the conventional laboratory method has been assessed in 60 diabetics and 70 controls. Results: The correlation between gingival and finger-stick blood was r = 0.996, P<0.001 in diabetics and controls. Correlation between gingival and laboratory method was r = 0.994, P<0.001 in cases and controls. Conclusion: The results suggest that capillary blood from the outer surface of gingiva provide an acceptable source for measuring blood glucose.

  12. Estimation of indocyanine green concentration in blood from fluorescence emission: application to hemodynamic assessment during hemodialysis

    Science.gov (United States)

    Maarek, Jean-Michel I.; Holschneider, Daniel P.

    2009-09-01

    There is considerable interest in assessing cardiovascular function noninvasively in patients receiving hemodialysis. A possible approach is to measure the blood concentration of bolus-injected indocyanine green dye and to apply the dye-dilution method for estimating cardiac output and blood volume. Blood ICG concentration can be derived from a measurement of the ICG fluorescence through the dialysis tubing if a simple and unique calibration relationship can be established between transmural fluorescence intensity and blood ICG concentration. We investigated this relationship using Monte Carlo simulations of light transport in blood with varying hematocrit and ICG concentrations and performed empiric measurements of optical absorption and ICG fluorescence emission to confirm our findings. The ICG fluorescence intensity measured at the blood surface, as well as the light intensity remitted by the blood, varied as hematocrit changes modified the absorption and scattering characteristics of the blood. Calibration relationships were developed between fluorescence intensity and ICG concentration that accounted for hematocrit changes. Combining the backreflected fluorescence and the reflected light measured near the point of illumination provided optimal signal intensity, linearity, and robustness to hematocrit changes. These results provide a basis for developing a noninvasive approach to derive optically circulating blood ICG concentration in hemodialysis circuits.

  13. Longitudinal assessment of high blood pressure in children with nonalcoholic fatty liver disease.

    Science.gov (United States)

    Schwimmer, Jeffrey B; Zepeda, Anne; Newton, Kimberly P; Xanthakos, Stavra A; Behling, Cynthia; Hallinan, Erin K; Donithan, Michele; Tonascia, James

    2014-01-01

    Nonalcoholic fatty liver disease (NAFLD) affects 9.6% of children and may put these children at elevated risk of high blood pressure and subsequent cardiovascular morbidity and mortality. Therefore, we sought to determine the prevalence of and risk factors for high blood pressure in children with NAFLD. Cohort study performed by the NIDDK NASH Clinical Research Network. There were 484 children with NAFLD ages 2 to 17 at enrollment; 382 children were assessed both at enrollment and 48 weeks afterwards. The main outcomes were high blood pressure at baseline and persistent high blood pressure at both baseline and 48 weeks. Prevalence of high blood pressure at baseline was 35.8% and prevalence of persistent high blood pressure was 21.4%. Children with high blood pressure were significantly more likely to have worse steatosis than children without high blood pressure (mild 19.8% vs. 34.2%, moderate 35.0% vs. 30.7%, severe 45.2% vs. 35.1%; P = 0.003). Higher body mass index, low-density lipoprotein, and uric acid were independent risk factors for high blood pressure (Odds Ratios: 1.10 per kg/m2, 1.09 per 10 mg/dL, 1.25 per mg/dL, respectively). Compared to boys, girls with NAFLD were significantly more likely to have persistent high blood pressure (28.4% vs.18.9%; P = 0.05). In conclusion, NAFLD is a common clinical problem that places children at substantial risk for high blood pressure, which may often go undiagnosed. Thus blood pressure evaluation, control, and monitoring should be an integral component of the clinical management of children with NAFLD.

  14. Longitudinal assessment of high blood pressure in children with nonalcoholic fatty liver disease.

    Directory of Open Access Journals (Sweden)

    Jeffrey B Schwimmer

    Full Text Available Nonalcoholic fatty liver disease (NAFLD affects 9.6% of children and may put these children at elevated risk of high blood pressure and subsequent cardiovascular morbidity and mortality. Therefore, we sought to determine the prevalence of and risk factors for high blood pressure in children with NAFLD.Cohort study performed by the NIDDK NASH Clinical Research Network. There were 484 children with NAFLD ages 2 to 17 at enrollment; 382 children were assessed both at enrollment and 48 weeks afterwards. The main outcomes were high blood pressure at baseline and persistent high blood pressure at both baseline and 48 weeks.Prevalence of high blood pressure at baseline was 35.8% and prevalence of persistent high blood pressure was 21.4%. Children with high blood pressure were significantly more likely to have worse steatosis than children without high blood pressure (mild 19.8% vs. 34.2%, moderate 35.0% vs. 30.7%, severe 45.2% vs. 35.1%; P = 0.003. Higher body mass index, low-density lipoprotein, and uric acid were independent risk factors for high blood pressure (Odds Ratios: 1.10 per kg/m2, 1.09 per 10 mg/dL, 1.25 per mg/dL, respectively. Compared to boys, girls with NAFLD were significantly more likely to have persistent high blood pressure (28.4% vs.18.9%; P = 0.05.In conclusion, NAFLD is a common clinical problem that places children at substantial risk for high blood pressure, which may often go undiagnosed. Thus blood pressure evaluation, control, and monitoring should be an integral component of the clinical management of children with NAFLD.

  15. Umbilical cord blood lactate: a valuable tool in the assessment of fetal metabolic acidosis

    DEFF Research Database (Denmark)

    Gjerris, A.C.; Staer-Jensen, J.; Jorgensen, J.S.

    2008-01-01

    OBJECTIVE: The aim of the present study was (1) to evaluate the relationship between umbilical cord arterial blood lactate and pH, standard base excess (SBE), and actual base excess (ABE) at delivery and (2) to suggest a cut-off level of umbilical cord arterial blood lactate in predicting fetal...... asphyxia using ROC-curves, where an ABE value less than -12 was used as "gold standard" for significant intrapartum asphyxia. STUDY DESIGN: This is a descriptive study of umbilical cord arterial blood samples from 2554 singleton deliveries. The deliveries took place at the Department of Obstetrics...... and Gynaecology, Hvidovre University Hospital, Copenhagen, Denmark where umbilical cord blood sampling and blood gas analysis is part of the routine assessment of all newborns. RESULTS: We found significant correlations between lactate and pH (r=-0.73), lactate and SBE (r=-0.76), and lactate and ABE (r=-0...

  16. Blood compounds irradiation process: assessment of absorbed dose using Fricke and Thermoluminescent dosimetric systems

    Energy Technology Data Exchange (ETDEWEB)

    Soares, Gabriela de Amorim; Squair, Peterson Lima; Pinto, Fausto Carvalho; Belo, Luiz Claudio Meira; Grossi, Pablo Andrade [Centro de Desenvolvimento da Tecnologia Nuclear (CDTN-CNEN/MG), Belo Horizonte, MG (Brazil)], e-mail: gas@cdtn.br, e-mail: pls@cdtn.br, e-mail: fcp@cdtn.br, e-mail: lcmb@cdtn.br, e-mail: pabloag@cdtn.br

    2009-07-01

    The assessment of gamma absorbed doses in irradiation facilities allows the quality assurance and control of the irradiation process. The liability of dose measurements is assign to the metrological procedures adopted including the uncertainty evaluation. Fricke and TLD 800 dosimetric systems were used to measure absorbed dose in the blood compounds using the methodology presented in this paper. The measured absorbed doses were used for evaluating the effectiveness of the irradiation procedure and the gamma dose absorption inside the irradiation room of a gamma irradiation facility. The radiation eliminates the functional and proliferative capacities of donor T-lymphocytes, preventing Transfusion associated graft-versus-host disease (TA-GVHD), a possible complication of blood transfusions. The results show the applicability of such dosimetric systems in quality assurance programs, assessment of absorbed doses in blood compounds and dose uniformity assign to the blood compounds irradiation process by dose measurements in a range between 25 Gy and 100 Gy. (author)

  17. Non-invasive assessment of pulmonary blood supply after staged repair of pulmonary atresia.

    OpenAIRE

    Del Torso, S.; Kelly, M J; Kalff, V; Stellin, G; Mee, R B; Venables, A W

    1985-01-01

    Radionuclide studies were performed to determine pulmonary blood flow in six children who had undergone surgery for pulmonary atresia, ventricular septal defect, and hypoplastic pulmonary arteries with or without major aortopulmonary collateral arteries. Lung blood flow was assessed from both particle perfusion lung scans and the pulmonary and systemic phase of a radionuclide dynamic flow study. Five patients had perfusion defects identified on the particle perfusion lung scan. In three of th...

  18. A content validated questionnaire for assessment of self reported venous blood sampling practices

    Directory of Open Access Journals (Sweden)

    Bölenius Karin

    2012-01-01

    Full Text Available Abstract Background Venous blood sampling is a common procedure in health care. It is strictly regulated by national and international guidelines. Deviations from guidelines due to human mistakes can cause patient harm. Validated questionnaires for health care personnel can be used to assess preventable "near misses"--i.e. potential errors and nonconformities during venous blood sampling practices that could transform into adverse events. However, no validated questionnaire that assesses nonconformities in venous blood sampling has previously been presented. The aim was to test a recently developed questionnaire in self reported venous blood sampling practices for validity and reliability. Findings We developed a questionnaire to assess deviations from best practices during venous blood sampling. The questionnaire contained questions about patient identification, test request management, test tube labeling, test tube handling, information search procedures and frequencies of error reporting. For content validity, the questionnaire was confirmed by experts on questionnaires and venous blood sampling. For reliability, test-retest statistics were used on the questionnaire answered twice. The final venous blood sampling questionnaire included 19 questions out of which 9 had in total 34 underlying items. It was found to have content validity. The test-retest analysis demonstrated that the items were generally stable. In total, 82% of the items fulfilled the reliability acceptance criteria. Conclusions The questionnaire could be used for assessment of "near miss" practices that could jeopardize patient safety and gives several benefits instead of assessing rare adverse events only. The higher frequencies of "near miss" practices allows for quantitative analysis of the effect of corrective interventions and to benchmark preanalytical quality not only at the laboratory/hospital level but also at the health care unit/hospital ward.

  19. The effect of electrostatic heparin/collagen layer-by-layer coating degradation on the biocompatibility

    Science.gov (United States)

    Chen, Jialong; Huang, Nan; Li, Quanli; Chu, Chun H.; Li, Jun; Maitz, Manfred F.

    2016-01-01

    Electrostatic layer-by-layer coatings of heparin and collagen have been suggested before to improve the biocompatibility of blood-contacting devices. However, to our knowledge, there have been no systematic studies about the effect of degradation of this coating on its biocompatibility, anticoagulant properties and the cyto-compatibility. The purpose of this study was to design an in vitro experiment in this regard that can assess the degradation behavior and the biocompatibility change of the coating. The coating degradation in physiological saline (PS) under static and dynamic condition was monitored by DR-FTIR, SEM, AFM and water contact angle, moreover, heparin densities on the topmost surface and the release heparin every day were measured by toluidine blue O (TBO) assay. The results showed that the degradation rate of the coating in is much faster under flow and shear conditions than during static incubation, and only very limited collagen and heparin remain on the surface after 15 days incubation in dynamic condition. With the degradation, the hemocompatibility of the coating got worse, especially when incubated under dynamic conditions. The degradation products of the coating do not lead to coagulation but behave -as heparin- anticoagulant. The compatibility of the coating to endothelial cells improved within 15d incubation in static medium, but it for degradation under dynamic conditions, it improved for 5d but at 15d incubation, it was almost as low as for the bare substrate. These results highlight the necessity for appropriate testing of newly developed coatings not only in the initial state but also after extended exposure to a physiological ambient.

  20. Bioglass: A novel biocompatible innovation

    Directory of Open Access Journals (Sweden)

    Vidya Krishnan

    2013-01-01

    Full Text Available Advancement of materials technology has been immense, especially in the past 30 years. Ceramics has not been new to dentistry. Porcelain crowns, silica fillers in composite resins, and glass ionomer cements have already been proved to be successful. Materials used in the replacement of tissues have come a long way from being inert, to compatible, and now regenerative. When hydroxyapatite was believed to be the best biocompatible replacement material, Larry Hench developed a material using silica (glass as the host material, incorporated with calcium and phosphorous to fuse broken bones. This material mimics bone material and stimulates the regrowth of new bone material. Thus, due to its biocompatibility and osteogenic capacity it came to be known as "bioactive glass-bioglass." It is now encompassed, along with synthetic hydroxyapatite, in the field of biomaterials science known as "bioactive ceramics." The aim of this article is to give a bird′s-eye view, of the various uses in dentistry, of this novel, miracle material which can bond, induce osteogenesis, and also regenerate bone.

  1. The Biocompatibility of Wool Keratin

    Institute of Scientific and Technical Information of China (English)

    LIU Mei; YU Wei-dong; WANG Xue-lei

    2007-01-01

    Keratin is the major structural fibrous protein providing outer covering such as hair, wool, feathers, etc. When being used as a kind of biomaterials, the biocompatibility of wool keratin is one of the most critical questions. By now, there has not been systemic study on the biocompatibiiity of keratin. Therefore, in this article we used the procedures of skin irritation, haemolysis and subcutaneous implantation according to ISO 10993 to study it. Moreover, the Fourier transform-infrared (FTIR) spectroscopy was utilized to analyse the impurity and structure modification of wool keratin film. The part of the animal tests showed that the wool keratin films prepared by authors were biocompatible. But the residual of sodium dodecyi sulfate (SDS) affected the results of other tests. Consequently, the wool keratin membrane is one kind of favourable and promising biomaterial for biomedical and histological utilization. The residual SDS used as an agent should be eliminated from the keratin solution or membrane completely if for biological usage. In conclusion, wool keratin, as a kind of natural protein, prospectively could be applied in biomedical materials and scaffolds of tissue engineering.

  2. Biocompatibility of plasma nanostructured biopolymers

    Energy Technology Data Exchange (ETDEWEB)

    Slepičková Kasálková, N. [Department of Solid State Engineering, Institute of Chemical Technology, 166 28 Prague (Czech Republic); Slepička, P., E-mail: petr.slepicka@vscht.cz [Department of Solid State Engineering, Institute of Chemical Technology, 166 28 Prague (Czech Republic); Bačáková, L. [Institute of Physiology, Academy of Sciences of the Czech Republic 142 20 Prague (Czech Republic); Sajdl, P. [Department of Power Engineering, Institute of Chemical Technology, 166 28 Prague (Czech Republic); Švorčík, V. [Department of Solid State Engineering, Institute of Chemical Technology, 166 28 Prague (Czech Republic)

    2013-07-15

    Many areas of medicine such as tissue engineering requires not only mastery of modification techniques but also thorough knowledge of the interaction of cells with solid state substrates. Plasma treatment can be used to effective modification, nanostructuring and therefore can significantly change properties of materials. In this work the biocompatibility of the plasma nanostructured biopolymers substrates was studied. Changes in surface chemical structure were studied by X-ray photoelectron spectroscopy (XPS). The morphology pristine and modified samples were determined using atomic force microscopy (AFM). The surface wettability was determined by goniometry from contact angle. Biocompatibility was determined by in vitro tests, the rat vascular smooth muscle cells (VSMCs) were cultivated on the pristine and plasma modified biopolymer substrates. Their adhesion, proliferation, spreading and homogeneous distribution on polymers was monitored. It was found that the plasma treatment leads to rapid decrease of contact angle for all samples. Contact angle decreased with increasing time of modification. XPS measurements showed that plasma treatment leads to changes in ratio of polar and non-polar groups. Plasma modification was accompanied by a change of surface morphology. Biological tests found that plasma treatment have positive effect on cells adhesion and proliferation cells and affects the size of cell’s adhesion area. Changes in plasma power or in exposure time influences the number of adhered and proliferated cells and their distribution on biopolymer surface.

  3. Factors influencing alginate gel biocompatibility.

    Science.gov (United States)

    Tam, Susan K; Dusseault, Julie; Bilodeau, Stéphanie; Langlois, Geneviève; Hallé, Jean-Pierre; Yahia, L'Hocine

    2011-07-01

    Alginate remains the most popular polymer used for cell encapsulation, yet its biocompatibility is inconsistent. Two commercially available alginates were compared, one with 71% guluronate (HiG), and the other with 44% (IntG). Both alginates were purified, and their purities were verified. After 2 days in the peritoneal cavity of C57BL/6J mice, barium (Ba)-gel and calcium (Ca)-gel beads of IntG alginate were clean, while host cells were adhered to beads of HiG alginate. IntG gel beads, however, showed fragmentation in vivo while HiG gel beads stayed firm. The physicochemical properties of the sodium alginates and their gels were thoroughly characterized. The intrinsic viscosity of IntG alginate was 2.5-fold higher than that of HiG alginate, suggesting a greater molecular mass. X-ray photoelectron spectroscopy indicated that both alginates were similar in elemental composition, including low levels of counterions in all gels. The wettabilities of the alginates and gels were also identical, as measured by contact angles of water on dry films. Ba-gel beads of HiG alginate resisted swelling and degradation when immersed in water, much more than the other gel beads. These results suggest that the main factors contributing to the biocompatibility of gels of purified alginate are the mannuronate/guluronate content and/or intrinsic viscosity.

  4. The impact of contact angle on the biocompatibility of biomaterials.

    Science.gov (United States)

    Menzies, Kara L; Jones, Lyndon

    2010-06-01

    Biomaterials may be defined as artificial materials that can mimic, store, or come into close contact with living biological cells or fluids and are becoming increasingly popular in the medical, biomedical, optometric, dental, and pharmaceutical industries. Within the ophthalmic industry, the best example of a biomaterial is a contact lens, which is worn by approximately 125 million people worldwide. For biomaterials to be biocompatible, they cannot illicit any type of unfavorable response when exposed to the tissue they contact. A characteristic that significantly influences this response is that related to surface wettability, which is often determined by measuring the contact angle of the material. This article reviews the impact of contact angle on the biocompatibility of tissue engineering substrates, blood-contacting devices, dental implants, intraocular lenses, and contact lens materials.

  5. [Histamine releasing activity of dental materials as the indicator of their biocompatibility].

    Science.gov (United States)

    Babakhin, A A; Volozhin, A I; Dubova, L V; Lebedenko, I Iu; Babakhina, Iu A; Zhuravleva, A A; Diubuske, L M

    2008-01-01

    Different types of dental materials (DM) were studied for their capacity to release histamine in vitro from basophils of whole blood of allergic patients and healthy donors using automated and computerized glass fiber-based leukocyte histamine release test (LHRT). It was shown that some types of DM possessed ability to release histamine from basophils and some didn't. There were no differences in histamine releaseability from basophils obtained from allergic patients and healthy donors. LHRT gives opportunity to recognize of DM possessing high or low histamine releaseability as well as to detect individual sensitivity to different DM. Thus, LHRT can be used for preliminary assessment of DM for their biocompatibility and also for individual selection of suitable DM for particular patient to avoid unwanted side effects.

  6. Assessing the association of severe malaria infection and ABO blood groups in northwestern Ethiopia

    Directory of Open Access Journals (Sweden)

    Hailu Tadesse

    2013-12-01

    Full Text Available Background & objectives: There is lack of adequate information on the association between severe malaria and some human genetic markers like ABO blood types. The study was undertaken to evaluate the association between severe malaria infection and ABO blood types among febrile patients attending Felegeselam Health Center, northwestern Ethiopia. Methods: A total of 398 febrile patients were examined for malaria and tested for ABO blood groups in December 2011. The blood samples were collected by finger pricking, stained with Giemsa and slides were examined microscopically. ABO blood group was determined by agglutination test using agglutinating A and B monoclonal anti-sera together with parasite load count. Chi-square and ANOVA tests were used to assess the difference between frequencies and means, respectively. Results: Out of 398 acute febrile patients, 201 (50.5% were found to be infected with Plasmodium parasites. Of which 194 (48.74% and 7 (1.76% belong to Plasmodium falciparum and P. vivax, respectively. The distribution of ABO blood groups was O (46%, A (27.1%, B (23.1% and AB (3.8%. The percentage of severe malaria with respect to blood group A, B, AB and O was found to be 40, 34.1, 14.3 and 5.1%, respectively. The association of severe malaria with non 'O' blood types was statistically significant (χ2 = 31.246, p <0.01. Interpretation & conclusion: The present findings indicate that individuals with blood groups A, B and AB are more susceptible for severe malaria infection than blood group O.

  7. Using venous blood gas analysis in the assessment of COPD exacerbations: a prospective cohort study.

    Science.gov (United States)

    McKeever, Tricia M; Hearson, Glenn; Housley, Gemma; Reynolds, Catherine; Kinnear, William; Harrison, Tim W; Kelly, Anne-Maree; Shaw, Dominick E

    2016-03-01

    Identifying acute hypercapnic respiratory failure is crucial in the initial management of acute exacerbations of COPD. Guidelines recommend obtaining arterial blood samples but these are more difficult to obtain than venous. We assessed whether blood gas values derived from venous blood could replace arterial at initial assessment. Patients requiring hospital treatment for an exacerbation of COPD had paired arterial and venous samples taken. Bland-Altman analyses were performed to assess agreement between arterial and venous pH, CO2 and HCO3-. The relationship between SpO2 and SaO2 was assessed. The number of attempts and pain scores for each sample were measured. 234 patients were studied. There was good agreement between arterial and venous measures of pH and HC)3- (mean difference 0.03 and -0.04, limits of agreement -0.05 to 0.11 and -2.90 to 2.82, respectively), and between SaO2 and SpO2 (in patients with an SpO2 of >80%). Arterial sampling required more attempts and was more painful than venous (mean pain score 4 (IQR 2-5) and 1 (IQR 0-2), respectively, pArterial sampling is more difficult and more painful than venous sampling. There is good agreement between pH and HCO3- values derived from venous and arterial blood, and between pulse oximetry and arterial blood gas oxygen saturations. These agreements could allow the initial assessment of COPD exacerbations to be based on venous blood gas analysis and pulse oximetry, simplifying the care pathway and improving the patient experience. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

  8. Dynamic in vivo biocompatibility of angiogenic peptide amphiphile nanofibers.

    Science.gov (United States)

    Ghanaati, Shahram; Webber, Matthew J; Unger, Ronald E; Orth, Carina; Hulvat, James F; Kiehna, Sarah E; Barbeck, Mike; Rasic, Angela; Stupp, Samuel I; Kirkpatrick, C James

    2009-10-01

    Biomaterials that promote angiogenesis have great potential in regenerative medicine for rapid revascularization of damaged tissue, survival of transplanted cells, and healing of chronic wounds. Supramolecular nanofibers formed by self-assembly of a heparin-binding peptide amphiphile and heparan sulfate-like glycosaminoglycans were evaluated here using a dorsal skinfold chamber model to dynamically monitor the interaction between the nanofiber gel and the microcirculation, representing a novel application of this model. We paired this model with a conventional subcutaneous implantation model for static histological assessment of the interactions between the gel and host tissue. In the static analysis, the heparan sulfate-containing nanofiber gels were found to persist in the tissue for up to 30 days and revealed excellent biocompatibility. Strikingly, as the nanofiber gel biodegraded, we observed the formation of a de novo vascularized connective tissue. In the dynamic experiments using the dorsal skinfold chamber, the material again demonstrated good biocompatibility, with minimal dilation of the microcirculation and only a few adherent leukocytes, monitored through intravital fluorescence microscopy. The new application of the dorsal skinfold model corroborated our findings from the traditional static histology, demonstrating the potential use of this technique to dynamically evaluate the biocompatibility of materials. The observed biocompatibility and development of new vascularized tissue using both techniques demonstrates the potential of these angiogenesis-promoting materials for a host of regenerative strategies.

  9. Broadband diffuse optical spectroscopy assessment of hemorrhage- and hemoglobin-based blood substitute resuscitation

    Science.gov (United States)

    Lee, Jangwoen; Kim, Jae G.; Mahon, Sari; Tromberg, Bruce J.; Mukai, David; Kreuter, Kelly; Saltzman, Darin; Patino, Renee; Goldberg, Robert; Brenner, Matthew

    2009-07-01

    Hemoglobin-based oxygen carriers (HBOCs) are solutions of cell-free hemoglobin (Hb) that have been developed for replacement or augmentation of blood transfusion. It is important to monitor in vivo tissue hemoglobin content, total tissue hemoglobin [THb], oxy- and deoxy-hemoglobin concentrations ([OHb], [RHb]), and tissue oxygen saturation (StO2=[OHb]/[THb]×100%) to evaluate effectiveness of HBOC transfusion. We designed and constructed a broadband diffuse optical spectroscopy (DOS) prototype system to measure bulk tissue absorption and scattering spectra between 650 and 1000 nm capable of accurately determining these tissue hemoglobin component concentrations in vivo. Our purpose was to assess the feasibility of using DOS to optically monitor tissue [OHb], [RHb], StO2, and total tissue hemoglobin concentration ([THb]=[OHb]+[RHb]) during HBOC infusion using a rabbit hypovolemic shock model. The DOS prototype probe was placed on the shaved inner thigh muscle of the hind leg to assess concentrations of [OHb], [RHb], [THb], as well as StO2. Hemorrhagic shock was induced in intubated New Zealand white rabbits (N=6) by withdrawing blood via a femoral arterial line to 20% blood loss (10-15 cc/kg). Hemoglobin glutamer-200 (Hb-200) 1:1 volume resuscitation was administered following the hemorrhage. These values were compared against traditional invasive measurements, serum hemoglobin concentration (sHGB), systemic blood pressure, heart rate, and blood gases. DOS revealed increases of [THb], [OHb], and tissue hemoglobin oxygen saturation after Hb-200 infusion, while blood total hemoglobin values continued did not increase; we speculate, due to hyperosmolality induced hemodilution. DOS enables noninvasive in vivo monitoring of tissue hemoglobin and oxygenation parameters during shock and volume expansion with HBOC and potentially enables the assessment of efficacy of resuscitation efforts using artificial blood substitutes.

  10. Design guidelines for an umbilical cord blood stem cell therapy quality assessment model

    Science.gov (United States)

    Januszewski, Witold S.; Michałek, Krzysztof; Yagensky, Oleksandr; Wardzińska, Marta

    The paper enlists the pivotal guidelines for producing an empirical umbilical cord blood stem cell therapy quality assessment model. The methodology adapted was single equation linear model with domain knowledge derived from MEDAFAR classification. The resulting model is ready for therapeutical application.

  11. In vivo biocompatibility evaluation of some Bidens tripartita extracts in rats.

    Science.gov (United States)

    Sandu, R B; Tarţău, L; Miron, A; Zagnat, M; Ghiciuc, C M; Lupuşoru, C E

    2013-01-01

    Adaptogens represent a class of herbs frequently used as a unique and natural alternative medicine and herbal remedy for treating the many forms of stress and different other pathological conditions. Bidens tripartite, a flowering plant from the genus Bidens, family Compositae, subfamily Asteroideae was widely used in traditional medicine for its antiseptic, anti-inflammatory, antioxidant, astringent, diuretic, febrifuge, narcotic and sedative effects. Phytochemical analysis of this plant has revealed the presence of flavonoids, xanthophylls, volatile oil, acetylene and polyacetylene, sterols, aurones, chalcones, caffeine and tannins. The in vivo biocompatibility evaluation of two extracts from Bidens tripartita plant in rats. The vegetable product used for the study was obtained after maceration and extraction in alcohol. Flower powder was dissolved in absolute chloroform, re-extracted and filtered. After a complete dryness the product was extracted by the addition of ethanol then evaporated. The chemical composition of the extracts was determined. The administered dose of Bidens tripartita retained was 1/20 of lethal dose 50 (LD50). The experiment was carried out on white male Wistar rats (200-250g) divided into 3 groups of 7 animals each treated intraperitoneally as follows: Group I (Control): distilled water 0.1ml/10g weight; Group II (coded BT-alcoholic): 200mg/kbw alcoholic Bidens tripartita extract; Group III (coded BT-aqueous): 250mg/kbw aqueous Bidens tripartita extract. The biocompatibility properties of alcoholic and aqueous extracts from Bidens tritartita were studied by assessing their effects on blood count and serum biochemical tests. The following immune parameters: phagocytic capacity of peripheral neutrophils (NBT test) and serum complement activity were also evaluated. The data were presented as +/- SD and significance was tested by SPSS for Windows version 13.0 and ANOVA method. Experimental protocol was implemented according to the

  12. The Blood Compatibilities of Blood Purification Membranes and Other Materials Developed in Japan

    Directory of Open Access Journals (Sweden)

    Takaya Abe

    2011-01-01

    Full Text Available The biocompatibilities in blood purification therapy are defined as “a concept to stipulate safety of blood purification therapy by an index based on interaction in the body arising from blood purification therapy itself.” The biocompatibilities are associated with not only materials to be used but also many factors such as sterilization method and eluted substance. It is often evaluated based on impacts on cellular pathways and on humoral pathways. Since the biocompatibilities of blood purification therapy in particular hemodialysis are not just a prognostic factor for dialysis patients but a contributory factor for long-term complications, it should be considered with adequate attention. It is important that blood purification therapy should be performed by consistently evaluating not only risks associated with these biocompatibilities but also the other advantages obtained from treatments. In this paper, the biocompatibilities of membrane and adsorption material based on Japanese original which are used for blood purification therapy are described.

  13. Non invasive blood flow assessment in diabetic foot ulcer using laser speckle contrast imaging technique

    Science.gov (United States)

    Jayanthy, A. K.; Sujatha, N.; Reddy, M. Ramasubba; Narayanamoorthy, V. B.

    2014-03-01

    Measuring microcirculatory tissue blood perfusion is of interest for both clinicians and researchers in a wide range of applications and can provide essential information of the progress of treatment of certain diseases which causes either an increased or decreased blood flow. Diabetic ulcer associated with alterations in tissue blood flow is the most common cause of non-traumatic lower extremity amputations. A technique which can detect the onset of ulcer and provide essential information on the progress of the treatment of ulcer would be of great help to the clinicians. A noninvasive, noncontact and whole field laser speckle contrast imaging (LSCI) technique has been described in this paper which is used to assess the changes in blood flow in diabetic ulcer affected areas of the foot. The blood flow assessment at the wound site can provide critical information on the efficiency and progress of the treatment given to the diabetic ulcer subjects. The technique may also potentially fulfill a significant need in diabetic foot ulcer screening and management.

  14. Altered phase interactions between spontaneous blood pressure and flow fluctuations in type 2 diabetes mellitus: Nonlinear assessment of cerebral autoregulation

    Science.gov (United States)

    Hu, Kun; Peng, C. K.; Huang, Norden E.; Wu, Zhaohua; Lipsitz, Lewis A.; Cavallerano, Jerry; Novak, Vera

    2008-04-01

    Cerebral autoregulation is an important mechanism that involves dilatation and constriction in arterioles to maintain relatively stable cerebral blood flow in response to changes of systemic blood pressure. Traditional assessments of autoregulation focus on the changes of cerebral blood flow velocity in response to large blood pressure fluctuations induced by interventions. This approach is not feasible for patients with impaired autoregulation or cardiovascular regulation. Here we propose a newly developed technique-the multimodal pressure-flow (MMPF) analysis, which assesses autoregulation by quantifying nonlinear phase interactions between spontaneous oscillations in blood pressure and flow velocity during resting conditions. We show that cerebral autoregulation in healthy subjects can be characterized by specific phase shifts between spontaneous blood pressure and flow velocity oscillations, and the phase shifts are significantly reduced in diabetic subjects. Smaller phase shifts between oscillations in the two variables indicate more passive dependence of blood flow velocity on blood pressure, thus suggesting impaired cerebral autoregulation. Moreover, the reduction of the phase shifts in diabetes is observed not only in previously-recognized effective region of cerebral autoregulation (type 2 diabetes mellitus alters cerebral blood flow regulation over a wide frequency range and that this alteration can be reliably assessed from spontaneous oscillations in blood pressure and blood flow velocity during resting conditions. We also show that the MMPF method has better performance than traditional approaches based on Fourier transform, and is more suitable for the quantification of nonlinear phase interactions between nonstationary biological signals such as blood pressure and blood flow.

  15. Dynamic and quantitative assessment of blood coagulation using optical coherence elastography

    Science.gov (United States)

    Xu, Xiangqun; Zhu, Jiang; Chen, Zhongping

    2016-04-01

    Reliable clot diagnostic systems are needed for directing treatment in a broad spectrum of cardiovascular diseases and coagulopathy. Here, we report on non-contact measurement of elastic modulus for dynamic and quantitative assessment of whole blood coagulation using acoustic radiation force orthogonal excitation optical coherence elastography (ARFOE-OCE). In this system, acoustic radiation force (ARF) is produced by a remote ultrasonic transducer, and a shear wave induced by ARF excitation is detected by the optical coherence tomography (OCT) system. During porcine whole blood coagulation, changes in the elastic property of the clots increase the shear modulus of the sample, altering the propagating velocity of the shear wave. Consequently, dynamic blood coagulation status can be measured quantitatively by relating the velocity of the shear wave with clinically relevant coagulation metrics, including reaction time, clot formation kinetics and maximum shear modulus. The results show that the ARFOE-OCE is sensitive to the clot formation kinetics and can differentiate the elastic properties of the recalcified porcine whole blood, blood added with kaolin as an activator, and blood spiked with fibrinogen.

  16. Rapid multi-wavelength optical assessment of circulating blood volume without a priori data

    Science.gov (United States)

    Loginova, Ekaterina V.; Zhidkova, Tatyana V.; Proskurnin, Mikhail A.; Zharov, Vladimir P.

    2016-03-01

    The measurement of circulating blood volume (CBV) is crucial in various medical conditions including surgery, iatrogenic problems, rapid fluid administration, transfusion of red blood cells, or trauma with extensive blood loss including battlefield injuries and other emergencies. Currently, available commercial techniques are invasive and time-consuming for trauma situations. Recently, we have proposed high-speed multi-wavelength photoacoustic/photothermal (PA/PT) flow cytometry for in vivo CBV assessment with multiple dyes as PA contrast agents (labels). As the first step, we have characterized the capability of this technique to monitor the clearance of three dyes (indocyanine green, methylene blue, and trypan blue) in an animal model. However, there are strong demands on improvements in PA/PT flow cytometry. As additional verification of our proof-of-concept of this technique, we performed optical photometric CBV measurements in vitro. Three label dyes—methylene blue, crystal violet and, partially, brilliant green—were selected for simultaneous photometric determination of the components of their two-dye mixtures in the circulating blood in vitro without any extra data (like hemoglobin absorption) known a priori. The tests of single dyes and their mixtures in a flow system simulating a blood transfusion system showed a negligible difference between the sensitivities of the determination of these dyes under batch and flow conditions. For individual dyes, the limits of detection of 3×10-6 M‒3×10-6 M in blood were achieved, which provided their continuous determination at a level of 10-5 M for the CBV assessment without a priori data on the matrix. The CBV assessment with errors no higher than 4% were obtained, and the possibility to apply the developed procedure for optical photometric (flow cytometry) with laser sources was shown.

  17. Assessment of blood coagulation under various flow conditions with ultrasound backscattering.

    Science.gov (United States)

    Huang, Chih-Chung; Wang, Shyh-Hau

    2007-12-01

    Several in vitro studies have employed ultrasonic techniques to detect varying properties of coagulating blood under static or stirred conditions. Most of those studies mainly addressed on the development and feasibility of modalities and however were not fully considering the effect of blood flow. To better elucidate this issue, ultrasonic backscattering were measured from the coagulating porcine blood circulated in a mock flow loop with various steady laminar flows at mean shear rates from 10 to 100 s(-1). A 3 ml of 0.5 M CaCl2 solution for inducing blood coagulation was added to that of 30 ml blood circulated in the conduit. For each measurement carried out with a 10-MHz transducer, backscattered signals digitized at 100-MHz sampling frequency were acquired for a total of 20 min at temporal resolution of 50 A-lines per s. The integrated backscatter (IB) was calculated for assessing backscattering properties of coagulating blood. The results show that blood coagulation tended to be increased corresponding to the addition of CaCl2 solution: the IB was increased approximately 6.1 +/- 0.6 (mean +/- standard deviation), 5.4 +/- 0.9, and 4.5 +/- 1.2 dB at 310 +/- 62, 420 +/- 88, and 610 +/- 102 s associated with mean shear rates of 10, 40, and 100 s(-1), respectively. The rate of increasing IB for evaluating the growth of clot was estimated to be 0.075 +/- 0.017, 0.052 +/- 0.027, and 0.038 +/- 0.012 delta dB delta s(-1) corresponding to the increase of mean shear rates. These results consistently demonstrate that higher shear rate tends to prolong the duration for the flowing blood to be coagulated and to decrease the rate of IB. Moreover, the laminar flow was changed to turbulent flow during that the blood was clotting discerned by spatial variations of ultrasound backscattering in the conduit. All these results validate that ultrasound backscattering is feasible to be utilized for detecting and assessing blood coagulation under dynamic conditions.

  18. Assessment of changes in liver blood flow after food intake—comparison of ICG clearance and echo-Doppler

    OpenAIRE

    Burggraaf, J; Schoemaker, H C; Cohen, A F

    1996-01-01

    Echo-Doppler measurements of portal venous blood flow in intrahepatic branches and indocyanine green (ICG) clearance after continuous i.v. infusion as measure for liver blood flow were compared to evaluate the increase in splanchnic blood flow after food intake. It was shown that both methods assessed the changes in flow in a similar manner. Changes in blood flow in intrahepatic portal vein branches measured with echo-Doppler adequately predicted the change in ICG concentrations. Hence, echo-...

  19. Transfer function analysis for the assessment of cerebral autoregulation using spontaneous oscillations in blood pressure and cerebral blood flow

    NARCIS (Netherlands)

    Abeelen, A.S.S. van den; Beek, A.H. van; Slump, C.H.; Panerai, R.B.; Claassen, J.A.H.R.

    2014-01-01

    Cerebral autoregulation (CA) is a key mechanism to protect the brain against excessive fluctuations in blood pressure (BP) and maintain cerebral blood flow. Analyzing the relationship between spontaneous BP and cerebral blood flow velocity (CBFV) using transfer function analysis is a widely used tec

  20. Increased DNA damage in blood cells of rat treated with lead as assessed by comet assay

    Directory of Open Access Journals (Sweden)

    Mohammad Arif

    2008-06-01

    Full Text Available A growing body of evidence suggests that oxidative stress is the key player in the pathogenesis of lead-induced toxicity. The present study investigated lead induced oxidative DNA damage, if any in rat blood cells by alkaline comet assay. Lead was administered intraperitoneally to rats at doses of 25, 50 and 100 mg/kg body weight for 5 days consecutively. Blood collected on day six from sacrificed lead-treated rats was used to assess the extent of DNA damage by comet assay which entailed measurement of comet length, olive tail moment, tail DNA (% and tail length. The results showed that treatment with lead significantly increased DNA damage in a dose-dependent manner. Therefore, our data suggests that lead treatment is associated with oxidative stress-induced DNA damage in rat blood cells which could be used as an early bio-marker of lead-toxicity.

  1. Peripheral venous blood gas analysis: An alternative to arterial blood gas analysis for initial assessment and resuscitation in emergency and intensive care unit patients.

    Science.gov (United States)

    Awasthi, Shilpi; Rani, Raka; Malviya, Deepak

    2013-01-01

    Arterial blood gas (ABG) analysis is the gold standard method for assessment of oxygenation and acid base analysis, yielding valuable information about a variety of disease process. This study is aimed to determine the extent of correlation between arterial and peripheral venous samples for blood gases and acid base status in critically ill and emergency department patients and to evaluate if venous sample may be a better alternative for initial assessment and resuscitation. The prospective study was conducted on 45 patients of either sex in the age group of 15-80 years of intensive care unit and emergency ward. Relevant history, presenting complaints, vital signs, and indication for testing were recorded. Arterial and peripheral venous samples were drawn simultaneously in a pre-heparinized syringe and analyzed immediately for blood gases and acid base status. Mean difference and Pearson's product moment correlation coefficient was used to compare the result. After statistical evaluation, the present study shows minimal mean difference and good correlation (r > 0.9) between arterial and peripheral venous sample for blood gases and acid base status. Correlation in PO2 measurement was poor (r blood may be a useful alternative to arterial blood during blood gas analysis obviating the need for arterial puncture in difficult clinical situation especially trauma patients, for initial emergency department assessment and early stages of resuscitation.

  2. Biocompatibility of crystalline opal nanoparticles

    Directory of Open Access Journals (Sweden)

    Hernández-Ortiz Marlen

    2012-10-01

    Full Text Available Abstract Background Silica nanoparticles are being developed as a host of biomedical and biotechnological applications. For this reason, there are more studies about biocompatibility of silica with amorphous and crystalline structure. Except hydrated silica (opal, despite is presents directly and indirectly in humans. Two sizes of crystalline opal nanoparticles were investigated in this work under criteria of toxicology. Methods In particular, cytotoxic and genotoxic effects caused by opal nanoparticles (80 and 120 nm were evaluated in cultured mouse cells via a set of bioassays, methylthiazolyldiphenyl-tetrazolium-bromide (MTT and 5-bromo-2′-deoxyuridine (BrdU. Results 3T3-NIH cells were incubated for 24 and 72 h in contact with nanocrystalline opal particles, not presented significant statistically difference in the results of cytotoxicity. Genotoxicity tests of crystalline opal nanoparticles were performed by the BrdU assay on the same cultured cells for 24 h incubation. The reduction of BrdU-incorporated cells indicates that nanocrystalline opal exposure did not caused unrepairable damage DNA. Conclusions There is no relationship between that particles size and MTT reduction, as well as BrdU incorporation, such that the opal particles did not induce cytotoxic effect and genotoxicity in cultured mouse cells.

  3. [Comparative assessing the effects of angelica root and chuanxiong on the hemorheology and the blood coagulation function in acute blood stasis rats].

    Science.gov (United States)

    Li, Wei-Xia; Tang, Yu-Ping; Guo, Jian-Ming

    2012-06-01

    To comparatively assess the effects of angelica root and chuanxiong on the hemorheology and the blood coagulation function in acute blood stasis rats. Ice water bath and subcutaneous injection of adrenaline were both used to establish the acute blood stasis rat model. The whole blood viscosity, plasma viscosity, erythrocyte sedimentation rate (ESR), and haematocrit were tested to observe the effects of angelica root and chuanxiong on the hemorheology of blood stasis rats. The prothrombin time (PT), activated partial thromboplastin time (APTT), and plasma fibrinogen (FIB) were tested to observe the effects of angelica root and chuanxiong on the blood coagulation function of blood stasis rats. Finally all those indices were integrated to the total activating blood circulation effect value to assess the total effects of angelica root and chuanxiong on activating blood circulation and dissipating blood stasis. Compared with the normal control group, the hemorheological indices obviously increased, PT and APTT were obviously shortened, and the FIB content obviously increased in the model group. Compared with the model group, the water extracts, alcohol extracts, water-alcohol extracts of angelica root, chuanxiong, angelica root and chuanxiong 1:1, and angelica root and chuanxiong 1.5:1 could decrease the hemorheological indices, prolong the PT and APTT, and significantly reduce the content of FIB. Under the condition of the same preparation method, the alcohol extract of angelica root and chuanxiong 1:1 showed the best total effect. As for the single herbs, chuanxiong had better effect than angelica root on the total effects of activating blood circulation and dissipating blood stasis. Under the condition of the same ratio, the alcohol extracts of angelica root and chuanxiong showed better total effects of activating blood circulation and dissipating blood stasis than water extracts and water-alcohol extracts. The angelica root and chuanxiong could obviously improve the

  4. Laboratory assessment of the hypertensive individual. Value of the main guidelines for high blood pressure

    Directory of Open Access Journals (Sweden)

    Reis Rafael S.

    1999-01-01

    Full Text Available OBJECTIVE: To determine if abnormal laboratory findings are more common in individuals with hypertension and in those with other risk factors, such as obesity, smoking and alcohol ingestion. METHODS: A study was carried out in the general outpatient clinics of a university hospital (145 individuals without previous diagnosis of hypertension and the following variables were assessed: high blood pressure (as defined by the VI Joint National Committee on Prevention, Detection and Treatment of High Blood Pressure - VI JNC, obesity [calculated using body mass index (BMI], tobacco use, and alcoholic ingestion. The laboratory examinations consisted of the following tests: hemogram, glycemia, uric acid, potassium, total/HDL-fraction cholesterol, triglycerides, calcium and creatinine. RESULTS: High blood pressure was not associated with a higher number of abnormal laboratory tests. Hypertensive individuals with a BMI > or = 25kg/m² or normotensive obese individuals, however, had a higher frequency of diabetes (12X, hypertriglyceridemia (3X, and hypercholesterolemia (2X, as compared with hypertensive individuals with BMI <25kg/m² and preobese/normal weight normotensive individuals. CONCLUSION: High blood pressure is not associated with a higher frequency of abnormal laboratory tests. The association of high blood pressure and obesity, however, increases the detection of diabetes and dyslipidemias.

  5. Clinical Assessment of Intraventricular Blood Transport in Patients Undergoing Cardiac Resynchronization Therapy

    Science.gov (United States)

    Rossini, Lorenzo; Martinez-Legazpi, P.; Benito, Y.; Perez Del Villar, C.; Gonzalez-Mansilla, A.; Barrio, A.; Yotti, R.; Kahn, A. M.; Shadden, S. C.; Fernandez-Aviles, F.; Bermejo, J.; Del Alamo, J. C.

    2015-11-01

    In the healthy heart, left ventricular (LV) filling generates flow patterns which have been proposed to optimize blood transport by coupling diastole and systole phases. We present a novel image-based method to assess how flow patterns influence LV blood transport in patients undergoing cardiac resynchronization therapy (CRT). Solving the advection equation with time-varying inflow boundary conditions allows to track the transport of blood entering the LV in the different filling waves, as well as the transport barriers which couple filling and ejection. The velocity fields were obtained using echocardiographic color Doppler velocimetry, which provides two-dimensional time-resolved flow maps in the apical long axis three-chamber view of the LV. We analyze flow transport in a group of patients with CRT devices as well as in healthy volunteers. In the patients under CRT, the device programming was varied to analyze flow transport under different values of the atrioventricular (AV) conduction delay and to model tachycardia. This analysis illustrates how CRT influences the transit of blood inside the LV, contributes to conserving kinetic energy and favors the generation of hemodynamic forces that accelerate blood in the direction of the LV outflow tract.

  6. Robustness of arterial blood gas analysis for assessment of respiratory safety pharmacology in rats.

    Science.gov (United States)

    Whiteside, Garth T; Hummel, Michele; Boulet, Jamie; Beyenhof, Jessica D; Strenkowski, Bryan; John, Janet Dell; Knappenberger, Terri; Maselli, Harry; Koetzner, Lee

    2016-01-01

    Whole body plethysmography using unrestrained animals is a common technique for assessing the respiratory risk of new drugs in safety pharmacology studies in rats. However, wide variations in experimental technique make cross laboratory comparison of data difficult and raise concerns that non-appropriate conditions may mask the deleterious effects of test compounds - in particular with suspected respiratory depressants. Therefore, the objective of this study was to evaluate the robustness of arterial blood gas analysis as an alternative to plethysmography in rats. We sought to do this by assessing the effect of different vehicles and times post-surgical catheterization on blood gas measurements, in addition to determining sensitivity to multiple opioids. Furthermore, we determined intra-lab variability from multiple datasets utilizing morphine and generated within a single lab and lastly, inter-lab variability was measured by comparing datasets generated in two separate labs. Overall, our data show that arterial blood gas analysis is a measure that is both flexible in terms of experimental conditions and highly sensitive to respiratory depressants, two key limitations when using plethysmography. As such, our data strongly advocate the adoption of arterial blood gas analysis as an investigative approach to reliably examine the respiratory depressant effects of opioids. Copyright © 2015 Elsevier Inc. All rights reserved.

  7. Biocompatibility evaluation of different alginates and alginate-based microcapsules.

    Science.gov (United States)

    Orive, G; Carcaboso, A M; Hernández, R M; Gascón, A R; Pedraz, J L

    2005-01-01

    Biocompatibility of biomaterials and biomaterial-based medical devices is a critical issue for the long-term function on multiple therapeutic systems. In the past few years, there has been an increasing interest in producing more biocompatible biomaterials and in developing novel assays to analyze the quality of the products. In this study, a battery of in vitro techniques to assess the biocompatibility of alginates with different compositions and purities and alginate-based microcapsules is presented. Study of the protein and polyphenol content of the alginates revealed clear differences between the nonpurified and the purified alginates. A similar behavior was observed when the mitogenic activity and the tumor necrosis factor-alphasecretion induced by the alginates were assessed. Interestingly, when the latter two techniques were adapted to evaluate the different alginate microcapsules, a correlation with the results obtained for the alginate samples was observed. These results reinforce the idea of using the full battery of assays here reported to screen alginates and alginate-based microcapsules before implantation.

  8. [IN VIVO EVALUATION OF POLYCAPROLACTONE-HYDROXYAPATITE SCAFFOLD BIOCOMPATIBILITY].

    Science.gov (United States)

    Ivanov, A N; Kozadaev, M N; Bogomolova, N V; Matveeva, O V; Puchinyan, D M; Norkin, I A; Sal'kovskii, Yu E; Lyubun, G P

    2015-01-01

    Biocompatibility is one of the main and very important properties for scaffolds. The aim of the present study was to investigate cells population dynamics in vivo in the process of original polycaprolactone-hydroxyapatite scaffold colonization, as well as tissue reactions to the implantation to assess the biocompatibility of the matrix. It has been found that tissue reactive changes in white rats subside completely up to the 21st day after subcutaneous polycaprolactone-hydroxyapatite scaffold implantation. Matrix was actively colonized by connective tissue cells in the period from the 7th to the 21st day of the experiment. However, intensive scaffold vascularization started from the 14th day after implantation. These findings suggest a high degree of the polycaprolactone-hydroxyapatite scaffold biocompatiblilitye.

  9. Assessment of cerebral blood flow autoregulation (CBF AR) with rheoencephalography (REG): studies in animals

    Science.gov (United States)

    Popovic, Djordje; Bodo, Michael; Pearce, Frederick; van Albert, Stephen; Garcia, Alison; Settle, Tim; Armonda, Rocco

    2013-04-01

    The ability of cerebral vasculature to regulate cerebral blood flow (CBF) in the face of changes in arterial blood pressure (SAP) or intracranial pressure (ICP) is an important guard against secondary ischemia in acute brain injuries, and official guidelines recommend that therapeutic decisions be guided by continuous monitoring of CBF autoregulation (AR). The common method for CBF AR monitoring, which rests on real-time derivation of the correlation coefficient (PRx) between slow oscillations in SAP and ICP is, however, rarely used in clinical practice because it requires invasive ICP measurements. This study investigated whether the correlation coefficient between SAP and the pulsatile component of the non-invasive transcranial bioimpedance signal (rheoencephalography, REG) could be used to assess the state and lower limit of CBF AR. The results from pigs and rhesus macaques affirm the utility of REG; however, additional animal and clinical studies are warranted to assess selectivity of automatic REG-based evaluation of CBF AR.

  10. Rheoencephalography (REG) as a Non-Invasive Monitoring Alternative for the Assessment of Brain Blood Flow

    Science.gov (United States)

    2004-09-01

    bioimpedance (rheoencephalography - REG) measurement as a non-invasive, continuous method for assessing the status of cerebral blood flow (CBF) in combat...Dunster KR, Colditz PB, Ward LC. Noninvasive measurement of cerebral bioimpedance for detection of cerebral edema in the neonatal piglet. Brain Res...REG measurements and DC impedance (Ro) were recorded simultaneously on a portable IBM compatible computer using CODAS (DATAQ, Inc., Akron, OH) data

  11. The use of finger-stick blood to assess lactate in critically ill surgical patients.

    Science.gov (United States)

    Sabat, Joseph; Gould, Scott; Gillego, Ezra; Hariprashad, Anita; Wiest, Christine; Almonte, Shailyn; Lucido, David J; Gave, Asaf; Leitman, I Michael; Eiref, Simon D

    2016-09-01

    Using finger-stick capillary blood to assess lactate from the microcirculation may have utility in treating critically ill patients. Our goals were to determine how finger-stick capillary lactate correlates with arterial lactate levels in patients from the surgical intensive care unit, and to compare how capillary and arterial lactate trend over time in patients undergoing resuscitation for shock. Capillary whole blood specimens were obtained from finger-sticks using a lancet, and assessed for lactate via a handheld point-of-care device as part of an "investigational use only" study. Comparison was made to arterial blood specimens that were assessed for lactate by standard laboratory reference methods. 40 patients (mean age 68, mean APACHEII 18, vasopressor use 62%) were included. The correlation between capillary and arterial lactate levels was 0.94 (p < 0.001). Capillary lactate measured slightly higher on average than paired arterial values, with a mean difference 0.99 mmol/L. In patients being resuscitated for septic and hemorrhagic shock, capillary and arterial lactate trended closely over time: rising, peaking, and falling in tandem. Clearance of capillary and arterial lactate mirrored clinical improvement, normalizing in all patients except two that expired. Finger-stick capillary lactate both correlates and trends closely with arterial lactate in critically ill surgical patients, undergoing resuscitation for shock.

  12. A biocompatible magnetic film: synthesis and characterization

    OpenAIRE

    Chatterjee, Jhunu; Haik, Yousef; Chen, Ching Jen

    2004-01-01

    Background Biotechnology applications of magnetic gels include biosensors, targeted drug delivery, artificial muscles and magnetic buckles. These gels are produced by incorporating magnetic materials in the polymer composites. Methods A biocompatible magnetic gel film has been synthesized using polyvinyl alcohol. The magnetic gel was dried to generate a biocompatible magnetic film. Nanosized iron oxide particles (γ-Fe2O3, ~7 nm) have been used to produce the magnetic gel. Results The surface ...

  13. [Assessment of arterial wall stiffness by 24-hour blood pressure monitoring].

    Science.gov (United States)

    Korneva, V A; Kuznetsova, T Yu

    2016-01-01

    Arterial wall stiffness is an early marker of cardiovascular diseases. The gold standard for assessment of the stiffness of large vessels is presently pulse wave velocity (PWV). Work is in progress on the study of the reference values of PWV in people of different genders and ages. 24-hour blood pressure (BP) monitoring is not only a procedure that can estimate diurnal BP variability, but also monitor the indicators of vascular wall stiffness in a number of cases over a 24-hour period. The given review highlights the pathophysiology of arterial stiffness, methods for its assessment, and the aspects of use in therapeutic practice.

  14. Carbon Fiber Biocompatibility for Implants

    Directory of Open Access Journals (Sweden)

    Richard Petersen

    2016-01-01

    Full Text Available Carbon fibers have multiple potential advantages in developing high-strength biomaterials with a density close to bone for better stress transfer and electrical properties that enhance tissue formation. As a breakthrough example in biomaterials, a 1.5 mm diameter bisphenol-epoxy/carbon-fiber-reinforced composite rod was compared for two weeks in a rat tibia model with a similar 1.5 mm diameter titanium-6-4 alloy screw manufactured to retain bone implants. Results showed that carbon-fiber-reinforced composite stimulated osseointegration inside the tibia bone marrow measured as percent bone area (PBA to a great extent when compared to the titanium-6-4 alloy at statistically significant levels. PBA increased significantly with the carbon-fiber composite over the titanium-6-4 alloy for distances from the implant surfaces of 0.1 mm at 77.7% vs. 19.3% (p < 10−8 and 0.8 mm at 41.6% vs. 19.5% (p < 10−4, respectively. The review focuses on carbon fiber properties that increased PBA for enhanced implant osseointegration. Carbon fibers acting as polymer coated electrically conducting micro-biocircuits appear to provide a biocompatible semi-antioxidant property to remove damaging electron free radicals from the surrounding implant surface. Further, carbon fibers by removing excess electrons produced from the cellular mitochondrial electron transport chain during periods of hypoxia perhaps stimulate bone cell recruitment by free-radical chemotactic influences. In addition, well-studied bioorganic cell actin carbon fiber growth would appear to interface in close contact with the carbon-fiber-reinforced composite implant. Resulting subsequent actin carbon fiber/implant carbon fiber contacts then could help in discharging the electron biological overloads through electrochemical gradients to lower negative charges and lower concentration.

  15. Assessing regional cerebral blood flow in depression using 320-slice computed tomography.

    Directory of Open Access Journals (Sweden)

    Yiming Wang

    Full Text Available While there is evidence that the development and course of major depressive disorder (MDD symptomatology is associated with vascular disease, and that there are changes in energy utilization in the disorder, the extent to which cerebral blood flow is changed in this condition is not clear. This study utilized a novel imaging technique previously used in coronary and stroke patients, 320-slice Computed-Tomography (CT, to assess regional cerebral blood flow (rCBF in those with MDD and examine the pattern of regional cerebral perfusion. Thirty nine participants with depressive symptoms (Hamilton Depression Rating Scale 24 (HAMD24 score > 20, and Self-Rating Depression Scale (SDS score > 53 and 41 healthy volunteers were studied. For all subjects, 3 ml of venous blood was collected to assess hematological parameters. Transcranial Doppler (TCD ultrasound was utilized to measure parameters of cerebral artery rCBFV and analyse the Pulsatility Index (PI. 16 subjects (8 =  MDD; 8 =  healthy also had rCBF measured in different cerebral artery regions using 320-slice CT. Differences among groups were analyzed using ANOVA and Pearson's tests were employed in our statistical analyses. Compared with the control group, whole blood viscosity (including high\\middle\\low shear rateand hematocrit (HCT were significantly increased in the MDD group. PI values in different cerebral artery regions and parameters of rCBFV in the cerebral arteries were decreased in depressive participants, and there was a positive relationship between rCBFV and the corresponding vascular rCBF in both gray and white matter. rCBF of the left gray matter was lower than that of the right in MDD. Major depression is characterized by a wide range of CBF impairments and prominent changes in gray matter blood flow. 320-slice CT appears to be a valid and promising tool for measuring rCBF, and could thus be employed in psychiatric settings for biomarker and treatment response purposes.

  16. 应用牙器官培养模型评价粘结剂的生物相容性%Biocompatibility assessment of two dental bonding agents with a rat tooth organ culture model

    Institute of Scientific and Technical Information of China (English)

    张金艳; 雷港; 于金华; 张光东

    2012-01-01

    AIM: To assess the biocompatibility of two dental bonding agents by rat loath organ culture model in vitro. METHODS: Cavities were prepared on labial surface of freshly extracted mandibular and maxillary incisors of 28-day old SD rat. The cavity walls were randomly conditionded with two dental bonding agents, Prime & Bond NT (PB) and Adper Prompt (AP), respectively. Non-conditioned walls served as control. After bonding, the cavities were filled with resin. The samples were maintained in sterile DMEM culture medium containing of fetal calf serum for one week. After culture, the tooth tissues were fixed in 10% formalin for 24h,followed by a demineralization process in 10% formic acid for 72 h and embedded in paraffin wax. Longitudinal sections of each tooth slice were cut with a microtome and stained with haematoxylin and eosin. Cell numbers within the dental pulp complex of each tooth slice were counted mstomorphometrically at X 40 magnification. RESULTS; Immediately after cavity filling, cells in subodontoblast cell layer aggregated in PB treated group, while a loss of morphologically intact odonloblast cells was found in AP treated group. Morphological changes were observed within the dentine-pulp complex of both PB and AP groups. After seven days culture, necrotic pulp cells were observed in AP group. While numbers of odontoblast cells decreased in PB group. Both groups showed morphological changes. CONCLUSION; Prime & Bond NT and Adper Prompt have cytotoxicity to dental pulp, and AP is more cytotoxic than PB at early stage.%目的:应用大鼠全牙器官培养模型对两种牙科粘结剂进行生物相容性评价.方法:在新鲜拔除的4周龄SD大鼠切牙唇面制洞,随机分成3组:对照组(不涂粘结剂);AP组(涂Adper Prompt粘结剂)和PB组(涂Prime &Bond NT粘结剂),3组洞壁做相应处理后光照10 s后填入树脂,分别于术后即刻和体外全牙培养1周两个时间点,40 g/L多聚甲醛(PBS)固定,100 g/L甲酸脱矿,常规切

  17. [Joint application of mathematic models in assessing the residual risk of hepatitis C virus transmitted through blood transfusion].

    Science.gov (United States)

    Wang, Xun; Jia, Yao; Xie, Yun-zheng; Li, Xiu-mei; Liu, Xiao-ying; Wu, Xiao-fei

    2011-09-01

    The practicable and effective methods for residual risk assessment on transfusion-transmitted disease was to establish the mathematic models. Based on the characteristics of the repeat donors which donated their blood on a regular base, a model of sero-conversion during the interval of donations was established to assess the incidence of the repeat donors. Based on the characteristics of the prevalence in the population, a model of 'prevalence increased with the age of the donor' was established to assess the incidence of those first-time donors. And based on the impact of the windows period through blood screening program, a model of residual risk associated with the incidence and the length of the windows period was established to assess the residual risk of blood transfusion. In this paper, above said 3 kinds of mathematic models were jointly applied to assess the residual risk of hepatitis C virus (HCV) which was transmitted through blood transfusion in Shanghai, based on data from the routine blood collection and screening program. All the anti-HCV unqualified blood donations were confirmed before assessment. Results showed that the residual risk of HCV transmitted through blood transfusion during Jan. 1(st), 2007 to Dec. 31(st), 2008 in Shanghai was 1:101 000. Data showed that the results of residual risk assessment with mathematic models was valuable. The residual risk of transfusion-transmitted HCV in Shanghai was at a safe level, according to the results in this paper.

  18. Zr{sub 61}Ti{sub 2}Cu{sub 25}Al{sub 12} metallic glass for potential use in dental implants: Biocompatibility assessment by in vitro cellular responses

    Energy Technology Data Exchange (ETDEWEB)

    Li, Jing [School of Stomatology, China Medical University, 117 Nanjing North Sreet, Shenyang, 110002 (China); Shi, Ling-ling; Zhu, Zhen-dong; He, Qiang [Shenyang National Laboratory for Materials Science, Institute of Metal Research, Chinese Academy of Sciences, 72 Wenhua Road, Shenyang, 110016 (China); Ai, Hong-jun, E-mail: aih0620@yahoo.com.cn [School of Stomatology, China Medical University, 117 Nanjing North Sreet, Shenyang, 110002 (China); Xu, Jian, E-mail: jianxu@imr.ac.cn [Shenyang National Laboratory for Materials Science, Institute of Metal Research, Chinese Academy of Sciences, 72 Wenhua Road, Shenyang, 110016 (China)

    2013-05-01

    In comparison with titanium and its alloys, Zr{sub 61}Ti{sub 2}Cu{sub 25}Al{sub 12} (ZT1) bulk metallic glass (BMG) manifests a good combination of high strength, high fracture toughness and lower Young's modulus. To examine its biocompatibility required for potential use in dental implants, this BMG was used as a cell growth subtract for three types of cell lines, L929 fibroblasts, human umbilical vein endothelial cells (HUVEC), and osteoblast-like MG63 cells. For a comparison, these cell lines were in parallel cultured and grown also on commercially pure titanium (CP-Ti) and Ti6–Al4–V alloy (Ti64). Cellular responses on the three metals, including adhesion, morphology and viability, were characterized using the SEM visualization and CCK-8 assay. Furthermore, real-time RT-PCR was used to measure the activity of integrin β, alkaline phosphatase (ALP) and type I collagen (COL I) in adherent MG63 cells. As indicated, in all cases of three cell lines, no significant differences in the initial attachment and viability/proliferation were found between ZT1, CP-Ti, and Ti64 until 5 d of incubation period. It means that the biocompatibility in cellular response for ZT1 BMG is comparable to Ti and its alloys. For gene expression of integrin β, ALP and COL I, mRNA level from osteoblast cells grown on ZT1 substrates is significantly higher than that on the CP-Ti and Ti64. It suggests that the adhesion and differentiation of osteoblasts grown on ZT1 are even superior to those on the CP-Ti and Ti64 alloy, then promoting bone formation. The good biocompatibility of ZT1 BMG is associated with the formation of zirconium oxide layer on the surface and good corrosion-resistance in physiological environment. Quantitative analysis of Real-time PCR for MG63 cells cultured on Zr{sub 61}Ti{sub 2}Cu{sub 25}Al{sub 12} BMG, CP-Ti, and Ti64 as well as plastic as a control at several incubation periods. Relative amounts of (a) integrin β, (b) ALP, and (c) COL I (*p < 0

  19. Quantitative immunohistochemical assessment of blood and lymphatic microcirculation in cutaneous lichen planus lesions.

    Science.gov (United States)

    Výbohová, Desanka; Mellová, Yvetta; Adamicová, Katarína; Adamkov, Marián; Hešková, Gabriela

    2015-06-01

    Latest advances have brought to light the hypothesis that angiogenesis and lymphangiogenesis are tightly connected to some chronic inflammatory diseases. The present study focuses on immunohistochemical assessment of the quantitative changes in the blood and lymphatic microcirculatory bed in common chronic dermatosis - cutaneous lichen planus. Double immunohistochemistry with CD34 and podoplanin antibodies was used to detect blood and lymphatic endothelium, while anti-human VEGF was used for the observation of a key angiogenesis and lymphangiogenesis inducer. Morphometric analysis was performed with QuickPhoto Micro image analysis software. Results confirmed statistically significant enlargement of both the blood and lymphatic microcirculatory beds. Compared to healthy skin, cutaneous lichen planus lesions revealed 1.6 times enlarged blood microcirculatory bed and 1.8 times enlarged lymphatic microcirculatory bed. Vascular endothelial growth factor (VEGF) expression in lesional skin was significantly higher in the epidermis (19.1 times increase) than in the dermis (10.3 times increase). These findings indicate a tight association of angiogenesis and lymphangiogenesis with the pathogenesis of cutaneous lichen planus.

  20. Systematic assessment of blood circulation time of functionalized upconversion nanoparticles in the chick embryo

    Science.gov (United States)

    Nadort, Annemarie; Liang, Liuen; Grebenik, Ekaterina; Guller, Anna; Lu, Yiqing; Qian, Yi; Goldys, Ewa; Zvyagin, Andrei

    2015-12-01

    Nanoparticle-based delivery of drugs and contrast agents holds great promise in cancer research, because of the increased delivery efficiency compared to `free' drugs and dyes. A versatile platform to investigate nanotechnology is the chick embryo chorioallantoic membrane tumour model, due to its availability (easy, cheap) and accessibility (interventions, imaging). In our group, we developed this model using several tumour cell lines (e.g. breast cancer, colon cancer). In addition, we have synthesized in-house silica coated photoluminescent upconversion nanoparticles with several functional groups (COOH, NH2, PEG). In this work we will present the systematic assessment of their in vivo blood circulation times. To this end, we injected chick embryos grown ex ovo with the functionalized UCNPs and obtained a small amount of blood at several time points after injection to create blood smears The UCNP signal from the blood smears was quantified using a modified inverted microscope imaging set-up. The results of this systematic study are valuable to optimize biochemistry protocols and guide nanomedicine advancement in the versatile chick embryo tumour model.

  1. Functional assessment of lesion severity without using the pressure wire: coronary imaging and blood flow simulation.

    Science.gov (United States)

    Papafaklis, Michail I; Mavrogiannis, Michail C; Siogkas, Panagiotis K; Lakkas, Lampros S; Katsouras, Christos S; Fotiadis, Dimitrios I; Michalis, Lampros K

    2017-09-19

    Hemodynamic indices derived from measurements with the pressure wire (primarily fractional flow reserve [FFR]) have been established as a reliable tool for assessing coronary stenoses and improving clinical decision making. However, the use of the pressure wire constitutes a hurdle for the universal adoption of physiology-guided patient management. Technological advancements have enabled the large-scale application of blood flow simulation (computational fluid dynamics [CFD]) to medical imaging, thereby enabling the virtual assessment of coronary physiology. Areas covered: This review summarizes the stand-alone non-invasive (coronary computed tomographic imaging) and invasive (coronary angiography) imaging approaches which were initially used for predicting FFR, and focuses on the use of blood flow modeling for functional assessment of coronary lesions in clinical practice. Expert commentary: Validation studies of CFD-derived methodologies for functional assessment have shown that virtual indices correlate well and have good diagnostic accuracy compared to pressure wire-FFR despite inherent limitations of spatial resolution and assumptions regarding boundary conditions in flow modeling. Beyond point-to-point agreement with FFR, further studies are needed to demonstrate the clinical safety/efficacy of these computational tools regarding patient outcomes. Such evidence base could support the incorporation of these methodologies into routine patient management for decision making and reliable risk stratification.

  2. Biomechanical and biocompatibility characteristics of electrospun polymeric tracheal scaffolds.

    Science.gov (United States)

    Ajalloueian, Fatemeh; Lim, Mei Ling; Lemon, Greg; Haag, Johannes C; Gustafsson, Ylva; Sjöqvist, Sebastian; Beltrán-Rodríguez, Antonio; Del Gaudio, Costantino; Baiguera, Silvia; Bianco, Alessandra; Jungebluth, Philipp; Macchiarini, Paolo

    2014-07-01

    The development of tracheal scaffolds fabricated based on electrospinning technique by applying different ratios of polyethylene terephthalate (PET) and polyurethane (PU) is introduced here. Prior to clinical implantation, evaluations of biomechanical and morphological properties, as well as biocompatibility and cell adhesion verifications are required and extensively performed on each scaffold type. However, the need for bioreactors and large cell numbers may delay the verification process during the early assessment phase. Hence, we investigated the feasibility of performing biocompatibility verification using static instead of dynamic culture. We performed bioreactor seeding on 3-dimensional (3-D) tracheal scaffolds (PET/PU and PET) and correlated the quantitative and qualitative results with 2-dimensional (2-D) sheets seeded under static conditions. We found that an 8-fold reduction for 2-D static seeding density can essentially provide validation on the qualitative and quantitative evaluations for 3-D scaffolds. In vitro studies revealed that there was notably better cell attachment on PET sheets/scaffolds than with the polyblend. However, the in vivo outcomes of cell seeded PET/PU and PET scaffolds in an orthotopic transplantation model in rodents were similar. They showed that both the scaffold types satisfied biocompatibility requirements and integrated well with the adjacent tissue without any observation of necrosis within 30 days of implantation.

  3. Mean Blood Pressure Assessment during Post-Exercise: Result from Two Different Methods of Calculation

    Directory of Open Access Journals (Sweden)

    Gianmarco Sainas, Raffaele Milia, Girolamo Palazzolo, Gianfranco Ibba, Elisabetta Marongiu, Silvana Roberto, Virginia Pinna, Giovanna Ghiani, Filippo Tocco, Antonio Crisafulli

    2016-09-01

    Full Text Available At rest the proportion between systolic and diastolic periods of the cardiac cycle is about 1/3 and 2/3 respectively. Therefore, mean blood pressure (MBP is usually calculated with a standard formula (SF as follows: MBP = diastolic blood pressure (DBP + 1/3 [systolic blood pressure (SBP – DBP]. However, during exercise this proportion is lost because of tachycardia, which shortens diastole more than systole. We analysed the difference in MBP calculation between the SF and a corrected formula (CF which takes into account changes in the diastolic and systolic periods caused by exercise-induced tachycardia. Our hypothesis was that the SF potentially induce a systematic error in MBP assessment during recovery after exercise. Ten healthy males underwent two exercise-recovery tests on a cycle-ergometer at mild-moderate and moderate-heavy workloads. Hemodynamics and MBP were monitored for 30 minutes after exercise bouts. The main result was that the SF on average underestimated MBP by –4.1 mmHg with respect to the CF. Moreover, in the period immediately after exercise, when sustained tachycardia occurred, the difference between SF and CF was large (in the order of -20-30 mmHg. Likewise, a systematic error in systemic vascular resistance assessment was present. It was concluded that the SF introduces a substantial error in MBP estimation in the period immediately following effort. This equation should not be used in this situation.

  4. The Quality Assessment of Stored Red Blood Cells Probed Using Atomic-Force Microscopy

    Directory of Open Access Journals (Sweden)

    I. M. Lamzin

    2014-01-01

    Full Text Available At the moment the suitability of stored red blood cells (sRBC for transfusion is checked by routine methods such as haemoglobin estimation and the level of haemolysis. These methods cannot characterize directly the quality of the membranes of sRBC. The aim of this work is to assess the quality of sRBC based on such criteria as the membrane’s stiffness and the size and the form of sRBC. Materials and Methods. We have investigated 5 series of dry cytosmears of the sRBC which had been kept in blood bank in a period from 1 to 35 days. After AFM imaging, in every specimen, 5 RBC were chosen at random; the diameter, the height, and the stiffness were measured on each of them. Results. The present study shows high increase of the mean values of YM and height of RBC after 35 days of storage and decrease of the mean values of their diameter. Conclusion. Statistically significant high increase of the mean values of YM indicates the decrease of the elasticity of the cells in the course of storing of the RBC. This parameter along with the morphological characteristics can be used as criterion for assessment of applicability of the sRBC for blood transfusion.

  5. The quality assessment of stored red blood cells probed using atomic-force microscopy.

    Science.gov (United States)

    Lamzin, I M; Khayrullin, R M

    2014-01-01

    At the moment the suitability of stored red blood cells (sRBC) for transfusion is checked by routine methods such as haemoglobin estimation and the level of haemolysis. These methods cannot characterize directly the quality of the membranes of sRBC. The aim of this work is to assess the quality of sRBC based on such criteria as the membrane's stiffness and the size and the form of sRBC. Materials and Methods. We have investigated 5 series of dry cytosmears of the sRBC which had been kept in blood bank in a period from 1 to 35 days. After AFM imaging, in every specimen, 5 RBC were chosen at random; the diameter, the height, and the stiffness were measured on each of them. Results. The present study shows high increase of the mean values of YM and height of RBC after 35 days of storage and decrease of the mean values of their diameter. Conclusion. Statistically significant high increase of the mean values of YM indicates the decrease of the elasticity of the cells in the course of storing of the RBC. This parameter along with the morphological characteristics can be used as criterion for assessment of applicability of the sRBC for blood transfusion.

  6. Quantitative assessment of regional myocardial blood flow with thallium-201 and SPECT.

    Science.gov (United States)

    Iida, H; Eberl, S

    1998-01-01

    Thallium-201 has been used extensively as a myocardial perfusion agent and to assess myocardial viability. Unlike other 99mTc-labeled agents such as 99mTc-sestamibi and 99mTc-tetrofosmine, the regional concentration of 201Tl varies with time, and its kinetics make it a potential candidate for estimating absolute physiologic parameters with kinetic model analysis. This article outlines a strategy for quantitative assessment of regional myocardial blood flow in man using 201Tl and dynamic single photon emission computed tomography (SPECT). Quantitatively accurate SPECT images that are proportional to the true radioactivity distribution are prerequisites for model-based kinetic analysis. Our technique for quantitative SPECT includes ordered-subset maximum likelihood-expectation maximization (ML-EM) reconstruction with transmission data-based attenuation correction and transmission-dependent convolution subtraction scatter correction. A three-compartment model was found to reproduce the observed regional time-activity curves well, and dog experiments demonstrated that influx rate constant (K1) values estimated from the dynamic SPECT data correlated well with absolute myocardial blood flow determined by in vitro microspheres for a physiologically wide range of flows. Several possible strategies for simplifying the study procedures, without compromising accuracy, are also presented, which should make absolute quantitation of regional myocardial blood flow feasible using 201Tl and a conventional SPECT camera in a clinical setting.

  7. Mean Blood Pressure Assessment during Post-Exercise: Result from Two Different Methods of Calculation.

    Science.gov (United States)

    Sainas, Gianmarco; Milia, Raffaele; Palazzolo, Girolamo; Ibba, Gianfranco; Marongiu, Elisabetta; Roberto, Silvana; Pinna, Virginia; Ghiani, Giovanna; Tocco, Filippo; Crisafulli, Antonio

    2016-09-01

    At rest the proportion between systolic and diastolic periods of the cardiac cycle is about 1/3 and 2/3 respectively. Therefore, mean blood pressure (MBP) is usually calculated with a standard formula (SF) as follows: MBP = diastolic blood pressure (DBP) + 1/3 [systolic blood pressure (SBP) - DBP]. However, during exercise this proportion is lost because of tachycardia, which shortens diastole more than systole. We analysed the difference in MBP calculation between the SF and a corrected formula (CF) which takes into account changes in the diastolic and systolic periods caused by exercise-induced tachycardia. Our hypothesis was that the SF potentially induce a systematic error in MBP assessment during recovery after exercise. Ten healthy males underwent two exercise-recovery tests on a cycle-ergometer at mild-moderate and moderate-heavy workloads. Hemodynamics and MBP were monitored for 30 minutes after exercise bouts. The main result was that the SF on average underestimated MBP by -4.1 mmHg with respect to the CF. Moreover, in the period immediately after exercise, when sustained tachycardia occurred, the difference between SF and CF was large (in the order of -20-30 mmHg). Likewise, a systematic error in systemic vascular resistance assessment was present. It was concluded that the SF introduces a substantial error in MBP estimation in the period immediately following effort. This equation should not be used in this situation.

  8. IMMUNOTOXICOLOGICAL ASPECTS OF BIOCOMPATIBILITY OF TITANIUM

    Directory of Open Access Journals (Sweden)

    Maya Lyapina

    2017-05-01

    Full Text Available Titanium (Ti is a non-essential metal element. TiO2 is used predominantly in the form of micro and nanoparticles in consumer products, including cosmetics and food. Because of its excellent biocompatibility, the trade-pure titan and its alloys are widely used as an alternative to certain metals in invasive medicine, surgery, dental medicine. Contemporary data concerning the sources of exposure to titanium, immune reactions to Ti alloys, current knowledge and perspectives of diagnosis of sensitization or allergic reactions to titanium are discussed. Conclusion: TiO2 is much more stable than pure Ti and alloys used in the implants, that should be taken into account when conducting research and analysing the results. The evidence of possible toxic effects is insufficient. It is difficult to assess the frequency of Ti allergy due to the uncertainty of diagnostic methods, but it is believed that it is very low. This is supported by the evidence that Ti and TiO2 (often as NP doesn’t penetrate through the healthy skin. Skin patch testing with currently available formulations of Ti and TiO2 has no significant value in clinical practice, and currently, it is assumed that there is no reliable method for diagnosis Ti allergy. The functional analysis of cytokine release and investigation of genetic characteristics could be useful for individual risk assessment in dental implantology. Such studies may also help to investigate separately early and late implant loss, as well as to develop new diagnostic tools.

  9. Doppler backscatter properties of a blood-mimicking fluid for Doppler performance assessment.

    Science.gov (United States)

    Ramnarine, K V; Hoskins, P R; Routh, H F; Davidson, F

    1999-01-01

    The Doppler backscatter properties of a blood-mimickig fluid (BMF) were studied to evaluate its suitability for use in a Doppler flow test object. Measurements were performed using a flow rig with C-flex tubing and BMF flow produced by a roller pump or a gear pump. A SciMed Doppler system was used to measure the backscattered Doppler power with a root-mean-square power meter connected to the audio output. Studies investigated the dependence of the backscattered Doppler power of the BMF with: circulation time; batch and operator preparations; storage; sieve size; flow speed; and pump type. A comparison was made with human red blood cells resuspended in saline. The backscatter properties are stable and within International Electrotechnical Commission requirements. The BMF is suitable for use in a test object for Doppler performance assessment.

  10. Central blood pressure assessment using 24-hour brachial pulse wave analysis

    Directory of Open Access Journals (Sweden)

    Muiesan ML

    2014-10-01

    Full Text Available Maria Lorenza Muiesan, Massimo Salvetti, Fabio Bertacchini, Claudia Agabiti-Rosei, Giulia Maruelli, Efrem Colonetti, Anna Paini Clinica Medica, Department of Clinical and Experimental Sciences, University of Brescia, Brescia, Italy Abstract: This review describes the use of central blood pressure (BP measurements during ambulatory monitoring, using noninvasive devices. The principles of measuring central BP by applanation tonometry and by oscillometry are reported, and information on device validation studies is described. The pathophysiological basis for the differences between brachial and aortic pressure is discussed. The currently available methods for central aortic pressure measurement are relatively accurate, and their use has important clinical implications, such as improving diagnostic and prognostic stratification of hypertension and providing a more accurate assessment of the effect of treatment on BP. Keywords: aortic blood pressure measurements, ambulatory monitoring, pulse wave analysis

  11. Biocompatibility evaluation of NiTi SMA stent via intervenient therapy

    Institute of Scientific and Technical Information of China (English)

    FENG; Jing-su; LIU; Kun-peng; KOU; Ya-ming

    2005-01-01

    NiTi shape memory alloy (SMA) stent with film are the long-term implanted medical devices which could be used in human's organ, such as esophagus, bile duct, urethra-prostate and blood vessel, by intervene therapy. It is very important to have a good biocompatibility for implanted device. According to standard ISO 10993, we completed biocompatibility evaluation of NiTi stent that included following tests: cytotoxicity, sensitization, genotoxicity, hemolysis and acute systemic toxicity, The results of tests qualify the NiTi stent, and provide an optimistic conclusion for the eventual use of NiTi stent as implanted medical devices.

  12. MR assessment of absolute myocardial blood flow and vasodilator flow reserve in patients with hypertrophic cardiomyopathy

    Energy Technology Data Exchange (ETDEWEB)

    Kawada, Nanaka; Sakuma, Hajime; Takeda, Kan; Nakagawa, Tsuyoshi; Yamakado, Tetsu; Nakano, Takeshi [Mie Univ., Tsu (Japan). School of Medicine

    1997-04-01

    Absolute coronary blood flow per myocardial mass and coronary flow reserve for the entire left ventricle were evaluated in normals and in patients with hypertrophic cardiomyopathy (HCM) by using fast cine MR imaging and fast velocity encoded cine (VENC) MR imaging. Nine healthy volunteers and 8 patients with HCM were studied with a 1.5 T imager. Breath-hold cine MR images encompassing the whole left ventricle were acquired on short axis imaging planes in order to evaluate myocardial mass. A fast VENC MR images were obtained to measure blood flow volume in the coronary sinus before and after dipyridamole administration (TR/TE=15/5 ms, FOV=28 x 22 cm, slice thickness=5 mm). Coronary flow reserve was calculated as a ratio of hyperemic to baseline coronary flow volumes. In the baseline state, coronary blood flow per myocardial mass was significantly lower in patients with HCM than in normal myocardium (0.56{+-}0.23 vs. 0.78{+-}0.27 ml/min/g, p<0.05). After dipyridamole administration, coronary blood flow per myocardial mass in patients with HCM increased substantially less than that in healthy subjects (0.99{+-}0.38 vs. 2.22{+-}0.55 ml/min/g, p<0.01), resulting in the significantly decreased coronary flow reserve ratio in HCM in comparison with that in normal myocardium (1.86{+-}0.56 vs. 3.11{+-}1.37, p<0.05). In conclusion, breath-hold velocity encoded cine MR imaging is a noninvasive technique which can provide assessments of altered coronary blood flow volume per myocardial mass and vasodilator flow reserve in patients with HCM. (author)

  13. Computational assessment of the effects of a pulsatile pump on toxin removal in blood purification

    Directory of Open Access Journals (Sweden)

    Shim Eun

    2010-06-01

    Full Text Available Abstract Background For blood purification systems using a semipermeable membrane, the convective mass transfer by ultrafiltration plays an important role in toxin removal. The increase in the ultrafiltration rate can improve the toxin removal efficiency of the device, ultimately reducing treatment time and cost. In this study, we assessed the effects of pulsatile flow on the efficiency of the convective toxin removal in blood purification systems using theoretical methods. Methods We devised a new mathematical lumped model to assess the toxin removal efficiency of blood purification systems in patients, integrating the mass transfer model for a human body with a dialyser. The human body model consists of a three-compartment model of body fluid dynamics and a two-compartment model of body solute kinetics. We simulated three types of blood purification therapy with the model, hemofiltration, hemodiafiltration, and high-flux dialysis, and compared the simulation results in terms of toxin (urea and beta-2 microglobulin clearance and the treatment dose delivered under conditions of pulsatile and non-pulsatile pumping. In vivo experiments were also performed to verify the model results. Results Simulation results revealed that pulsatile flow improved the convective clearance of the dialyser and delivered treatment dose for all three types of therapy. Compared with the non-pulsatile pumping method, the increases in the clearance of urea and beta-2 microglobulin with pulsatile pumping were highest with hemofiltration treatment (122.7% and 122.7%, respectively, followed by hemodiafiltration (3.6% and 8.3%, respectively, and high-flux dialysis (1.9% and 4.7%, respectively. EKRc and std Kt/V averaged 28% and 23% higher, respectively, in the pulsatile group than in the non-pulsatile group with hemofiltration treatment. Conclusions The pulsatile effect was highly advantageous for all of the toxins in the hemofiltration treatment and for β2-microglobulin in

  14. [Cerebral blood flow assessment of preterm infants during respiratory therapy with the expiratory flow increase technique].

    Science.gov (United States)

    Bassani, Mariana Almada; Caldas, Jamil Pedro Siqueira; Netto, Abimael Aranha; Marba, Sérgio Tadeu Martins

    2016-06-01

    To assess the impact of respiratory therapy with the expiratory flow increase technique on cerebral hemodynamics of premature newborns. This is an intervention study, which included 40 preterm infants (≤34 weeks) aged 8-15 days of life, clinically stable in ambient air or oxygen catheter use. Children with heart defects, diagnosis of brain lesion and/or those using vasoactive drugs were excluded. Ultrasonographic assessments with transcranial Doppler flowmetry were performed before, during and after the increase in expiratory flow session, which lasted 5minutes. Cerebral blood flow velocity and resistance and pulsatility indices in the pericallosal artery were assessed. Respiratory physical therapy did not significantly alter flow velocity at the systolic peak (p=0.50), the end diastolic flow velocity (p=0.17), the mean flow velocity (p=0.07), the resistance index (p=0.41) and the pulsatility index (p=0.67) over time. The expiratory flow increase technique did not affect cerebral blood flow in clinically-stable preterm infants. Copyright © 2015 Sociedade de Pediatria de São Paulo. Publicado por Elsevier Editora Ltda. All rights reserved.

  15. Cerebral blood flow assessment of preterm infants during respiratory therapy with the expiratory flow increase technique

    Directory of Open Access Journals (Sweden)

    Mariana Almada Bassani

    2016-06-01

    Full Text Available Abstract Objective: To assess the impact of respiratory therapy with the expiratory flow increase technique on cerebral hemodynamics of premature newborns. Methods: This is an intervention study, which included 40 preterm infants (≤34 weeks aged 8-15 days of life, clinically stable in ambient air or oxygen catheter use. Children with heart defects, diagnosis of brain lesion and/or those using vasoactive drugs were excluded. Ultrasonographic assessments with transcranial Doppler flowmetry were performed before, during and after the increase in expiratory flow session, which lasted 5min. Cerebral blood flow velocity and resistance and pulsatility indices in the pericallosal artery were assessed. Results: Respiratory physical therapy did not significantly alter flow velocity at the systolic peak (p=0.50, the end diastolic flow velocity (p=0.17, the mean flow velocity (p=0.07, the resistance index (p=0.41 and the pulsatility index (p=0.67 over time. Conclusions: The expiratory flow increase technique did not affect cerebral blood flow in clinically-stable preterm infants.

  16. Assessment of skin flaps using optically based methods for measuring blood flow and oxygenation.

    Science.gov (United States)

    Payette, Jeri R; Kohlenberg, Elicia; Leonardi, Lorenzo; Pabbies, Arone; Kerr, Paul; Liu, Kan-Zhi; Sowa, Michael G

    2005-02-01

    The objective of this study was to compare two noninvasive techniques, laser Doppler and optical spectroscopy, for monitoring hemodynamic changes in skin flaps. Animal models for assessing these changes in microvascular free flaps and pedicle flaps were investigated. A 2 x 3-cm free flap model based on the epigastric vein-artery pair and a reversed MacFarlane 3 x 10-cm pedicle flap model were used in this study. Animals were divided into four groups, with groups 1 (n = 6) and 2 (n = 4) undergoing epigastric free flap surgery and groups 3 (n = 3) and 4 (n = 10) undergoing pedicle flap surgery. Groups 1 and 4 served as controls for each of the flap models. Groups 2 and 3 served as ischemia-reperfusion models. Optical spectroscopy provides a measure of hemoglobin oxygen saturation and blood volume, and the laser Doppler method measures blood flow. Optical spectroscopy proved to be consistently more reliable in detecting problems with arterial in flow compared with laser Doppler assessments. When spectroscopy was used in an imaging configuration, oxygen saturation images of the entire flap were generated, thus creating a visual picture of global flap health. In both single-point and imaging modes the technique was sensitive to vessel manipulation, with the immediate post operative images providing an accurate prediction of eventual outcome. This series of skin flap studies suggests a potential role for optical spectroscopy and spectroscopic imaging in the clinical assessment of skin flaps.

  17. Assessment of the levels of hexachlorocyclohexane in blood samples from Mexico.

    Science.gov (United States)

    Trejo-Acevedo, Antonio; Rivero-Pérez, Norma Edith; Flores-Ramirez, Rogelio; Orta-García, Sandra Teresa; Pruneda-Álvarez, Lucia Guadalupe; Pérez-Maldonado, Iván N

    2012-06-01

    The aim of this study was to evaluate hexachlorocyclohexane (HCH) exposure in children living in nine hot spots in four Mexican states. We analyzed HCH (α, β, and γ-isomers) in blood using gas chromatography/mass spectrometry. HCH exposure level in 261 children was assessed and approximately 75 % of the children studied had detectable levels of HCH. These levels ranged from 188 to 40,096.7 ng/g lipid. The highest mean levels were found in Lacanja (5,446.9 ng/g lipid), an indigenous community in Chiapas, Mexico. Our data indicate high exposure to HCH in children living in these communities.

  18. The Quality Assessment of Stored Red Blood Cells Probed Using Atomic-Force Microscopy

    OpenAIRE

    Lamzin, I. M.; Khayrullin, R. M.

    2014-01-01

    At the moment the suitability of stored red blood cells (sRBC) for transfusion is checked by routine methods such as haemoglobin estimation and the level of haemolysis. These methods cannot characterize directly the quality of the membranes of sRBC. The aim of this work is to assess the quality of sRBC based on such criteria as the membrane’s stiffness and the size and the form of sRBC. Materials and Methods. We have investigated 5 series of dry cytosmears of the sRBC which had been kept in b...

  19. Efficiency and biocompatibility of a polyethylene glycol grafted cellulosic membrane during hemodialysis.

    Science.gov (United States)

    Akizawa, T; Kino, K; Koshikawa, S; Ikada, Y; Kishida, A; Yamashita, M; Imamura, K

    1989-01-01

    Dialytic efficiency and biocompatibility of a new modified cellulose membrane (NMC) were examined in vitro and clinically. NMC was obtained by grafting polyethylene-glycol (PEG) chains to the membrane surface of ordinary cellulose (OC), and it was expected that the random movement of PEG chains would prevent blood cells and large plasma proteins from coming into contact with the membrane surface, resulting in improving the biocompatibility and thrombogenicity of the membrane. Surface characteristics of NMC were rendered anionic and hydrophilic, however, the activations of complement and platelet systems were clearly suppressed in NMC. Minimum heparin requirement for hemodialysis was significantly lower with NMC than with OC dialyzer. No significant difference in solute and water removal was observed between the two dialyzers. These results indicate that NMC can provide increased biocompatibility and antithrombogenic effect while retaining the essential dialysis efficiency of OC.

  20. A rheological and microscopical characterization of biocompatible ferrofluids

    Energy Technology Data Exchange (ETDEWEB)

    Nowak, J., E-mail: johannes.nowak@tu-dresden.de [Chair of Magnetofluiddynamics, Measuring and Automation Technology, Technische Universität Dresden, 01069 Germany (Germany); Wolf, D. [Triebenberg Laboratory, Technische Universität Dresden, 01328 Germany (Germany); Odenbach, S. [Chair of Magnetofluiddynamics, Measuring and Automation Technology, Technische Universität Dresden, 01069 Germany (Germany)

    2014-03-15

    There is an increasing interest in suspensions of magnetic nanoparticles in the biomedical area. Those ferrofluids are e.g. used for magnetic resonance imaging and emerging research focuses on employing the fluids for magnetic drug targeting or magnetic particle heating as a potential treatment for cancer. For these applications the knowledge of the suspensions' thermophysical properties is of major interest to guarantee a safe and effective application. Therefore the flow behavior cannot be neglected as it might significantly influence the execution of the aforementioned applications. In this experimental study two biocompatible ferrofluids were investigated. Rheological measurements were carried out using rotational rheometry. To allow an interpretation of the fluids' behavior the microscopic make-up was investigated using dynamic light scattering and transmission electron microscopy. Measurements of diluted ferrofluids were carried out as a first step to simulate the rheological behavior reflecting the concentration of magnetic nanoparticles found in blood flow for most biomedical applications of such fluids. The detected strong effects show the potential to significantly influence application and handling of the biocompatible ferrofluids in the medical area and should therefore be taken into account for further research as well as for the application of such fluids. - Highlights: • The rheology of biocompatible multicore ferrofluids is influenced by magnetic fields. • The flow curves can be described by the Herschel–Bulkley model. • A connection between the magnetoviscous effect and the particle size is found. • The strong magnetoviscous effect exists even if the fluids are diluted. • The connection between the effect and the dilution is mathematically described.

  1. A capillary viscometer designed for the characterization of biocompatible ferrofluids

    Science.gov (United States)

    Nowak, J.; Odenbach, S.

    2016-08-01

    Suspensions of magnetic nanoparticles are receiving a growing interest in biomedical research. These ferrofluids can, e.g., be used for the treatment of cancer, making use of the drug targeting principle or using an artificially induced heating. To enable a safe application the basic properties of the ferrofluids have to be well understood, including the viscosity of the fluids if an external magnetic field is applied. It is well known that the viscosity of ferrofluids rises if a magnetic field is applied, where the rise depends on shear rate and magnetic field strength. In case of biocompatible ferrofluids such investigations proved to be rather complicated as the experimental setup should be close to the actual application to allow justified predictions of the effects which have to be expected. Thus a capillary viscometer, providing a flow situation comparable to the flow in a blood vessel, has been designed. The glass capillary is exchangeable and different inner diameters can be used. The range of the shear rates has been adapted to the range found in the human organism. The application of an external magnetic field is enabled with two different coil setups covering the ranges of magnetic field strengths required on the one hand for a theoretical understanding of particle interaction and resulting changes in viscosity and on the other hand for values necessary for a potential biomedical application. The results show that the newly designed capillary viscometer is suitable to measure the magnetoviscous effect in biocompatible ferrofluids and that the results appear to be consistent with data measured with rotational rheometry. In addition, a strong change of the flow behaviour of a biocompatible ferrofluid was proven for ranges of the shear rate and the magnetic field strength expected for a potential biomedical application.

  2. Rapid assessment of iron in blood plasma and serum by spectrophotometry with cloud-point extraction.

    Science.gov (United States)

    Samarina, Tatyana; Proskurnin, Mikhail

    2015-01-01

    Rapid photometric assessment of iron in blood plasma and serum by a simple procedure after the extraction of iron(II) complex with 1-nitroso-2-naphthol in the micellar phase of a nonionic surfactant at the cloud point upon heating (pH range is 4.5-6.3) is proposed. The procedure trueness was verified using a standard reference protocol using bathophenanthroline. The advantages of the procedure are higher sensitivity than the reference protocol: the limit of detection is 0.03 μg/mL, the limit of quantitation is 0.1 μg/mL, the determination range is 0.1 - 2.8 μg/mL (RSD 0.02-0.10). Copper does not interfere with the iron assessment.

  3. Mobile phone based laser speckle contrast imager for assessment of skin blood flow

    Science.gov (United States)

    Jakovels, Dainis; Saknite, Inga; Krievina, Gita; Zaharans, Janis; Spigulis, Janis

    2014-10-01

    Assessment of skin blood flow is of interest for evaluation of skin viability as well as for reflection of the overall condition of the circulatory system. Laser Doppler perfusion imaging (LDPI) and laser speckle contrast imaging (LASCI) are optical techniques used for assessment of skin perfusion. However, these systems are still too expensive and bulky to be widely available. Implementation of such techniques as connection kits for mobile phones have a potential for primary diagnostics. In this work we demonstrate simple and low cost LASCI connection kit for mobile phone and its comparison to laser Doppler perfusion imager. Post-occlusive hyperemia and local thermal hyperemia tests are used to compare both techniques and to demonstrate the potential of LASCI device.

  4. New Criteria for Assessing the Accuracy of Blood Glucose Monitors meeting, October 28, 2011.

    Science.gov (United States)

    Walsh, John; Roberts, Ruth; Vigersky, Robert A; Schwartz, Frank

    2012-03-01

    Glucose meters (GMs) are routinely used for self-monitoring of blood glucose by patients and for point-of-care glucose monitoring by health care providers in outpatient and inpatient settings. Although widely assumed to be accurate, numerous reports of inaccuracies with resulting morbidity and mortality have been noted. Insulin dosing errors based on inaccurate GMs are most critical. On October 28, 2011, the Diabetes Technology Society invited 45 diabetes technology clinicians who were attending the 2011 Diabetes Technology Meeting to participate in a closed-door meeting entitled New Criteria for Assessing the Accuracy of Blood Glucose Monitors. This report reflects the opinions of most of the attendees of that meeting. The Food and Drug Administration (FDA), the public, and several medical societies are currently in dialogue to establish a new standard for GM accuracy. This update to the FDA standard is driven by improved meter accuracy, technological advances (pumps, bolus calculators, continuous glucose monitors, and insulin pens), reports of hospital and outpatient deaths, consumer complaints about inaccuracy, and research studies showing that several approved GMs failed to meet FDA or International Organization for Standardization standards in postapproval testing. These circumstances mandate a set of new GM standards that appropriately match the GMs' analytical accuracy to the clinical accuracy required for their intended use, as well as ensuring their ongoing accuracy following approval. The attendees of the New Criteria for Assessing the Accuracy of Blood Glucose Monitors meeting proposed a graduated standard and other methods to improve GM performance, which are discussed in this meeting report.

  5. Fourier Analysis of Peripheral Blood Pressure and Flow in Intraoperative Assessment of Infrainguinal Arterial Reconstructions

    Directory of Open Access Journals (Sweden)

    Cheshmedzhiev Mihail V.

    2014-08-01

    Full Text Available AIM: To assess infrainguinal arterial reconstructions by intraoperative flowmetry under the distal anastomosis using a fast Fourier transformation; calculate and compare the amplitude ratios of peripheral arterial blood pressure and volume flow before and after drug-induced vasodilation of occluded bypass grafts and bypass grafts that have been patent at least for 1 year. To find what magnitude of the change of these ratios indicate a long-term patency of the bypass grafting. PATIENTS AND METHODS: We compared the results of the intraoperative flowmetry tests of 97 patients with infrainguinal arterial reconstructions. The patients were divided into two groups based on the graft status: the grafts in 49 patients were patent for at least a year, and 48 patients had failed bypass. We used a fast Fourier transform (FFT of the pressure and blood flow waves and compared the ratios of their amplitudes before and after administration of a vasodilator drug into the graft. Comparing the ratios obtained before and those after administration of the drug we quantified their change in each group and analysed them. RESULTS: After a drug-induced vasodilation, the blood pressure and flow amplitude ratios for the group with compromised reconstructions were less than 1.9 times smaller than those before drug infusion, while for the group with bypass grafts that had been functional for at least 12 months the ratios declined by more than 1.9≈2 times. CONCLUSION: The magnitude of the change of amplitude ratios of the peripheral pressure and volume flow after drug-induced vasodilation can be used to make an assessment of the bypass graft and the distal arterial segment.

  6. [Single-donor (apheresis) platelets and pooled whole-blood-derived platelets--significance and assessment of both blood products].

    Science.gov (United States)

    Hitzler, Walter E

    2014-01-01

    The transfusion efficacy of ATK, which contain fully functional platelets, is beyond all doubt. The equivalence of ATK and PTK has been subject of many studies. Some of those studies show the superiority of ATK's, while others do not, but there have been no studies that demonstrated a superiority of PTK's. The superiority of platelets stored in plasma and in third generation additive solution was demonstrated in clinical studies; therefore, it cannot be said that all the platelet concentrates on the German market are equivalent in efficacy. Of decisive importance, above all, is the risk of transfusion-transmitted infections with known pathogens, or those not yet discovered. This risk is different for ATK compared to PTK. Taking this difference in risk and the difference in donor exposure of transfused patients into account, it can definitely be said that ATK and PTK are not equivalent. In 2012, the Robert-Koch-Institute (RKI) published a mathematical risk model for different platelet concentrates and assessed the risk of transmitting known pathogens such as HIV, HCV, and HBV. The risk was higher for PTK compared to ATK. The relative risks for PTK derived from 4BCs were 2.2 (95%--CI: 2.1-2.4) for HIV, 2.7 (95%--CI: 2.5-3.0) for HCV, and 2.2 (95%--CI: 2.8-3.7) for HBV. At the present time, these are the relative risks of transfusion-transmitted infections with the traditional pathogens for PTK compared to ATK. In addition to the RKI assessed risks, there is the theoretical risk of a new, unknown agent, transmitted through blood exposure. The magnitude of this risk is hardly predictable for PTK. The experience gathered so far, especially in the last three decades, with the emergence of HIV, prions, and West Nil virus, shows that the biological nature of a next transfusion-transmissible infectious agent cannot be predictable. This agent, if we think at a conventional sexually transmissible agent with nucleic acid and long latent period, would spread first in areas with

  7. Clinical assessment of quality of life of the patients with chronic blood transfusion and chelation therapy

    Directory of Open Access Journals (Sweden)

    Tamil Selvan

    2014-01-01

    Full Text Available Background: The patient with hemoglobinopathy like thalassemia major (TM, bone marrow dysfunction, and sickle cell disease are requiring chronic blood transfusion for their life time to survive. Among these, TM is one of the most common hemoglobinopathy worldwide. Objective: This study is done to assess the quality of life (QOL of the patients with chronic blood transfusion and chelation therapy. Materials and Methods: The QOL scores were obtained through the self-administered SF-36 questionnaire. The study subjects were asked to answer the SF-36 questionnaire once every 3 months. Results: After 6 months, the SF 36 general health mean score was 63.58 ± 12.98 (P < 0.05. The highest mean score was 69.37 ± 11.61. The mean difference after the final reviews was statistically significant. Conclusion: The preponderance of scores used to assess QOL suggests that there is a direct and independent effect on QOL when treated with transfusion and iron-chelation therapy.

  8. Photoacoustic ultrasound spectroscopy for assessing red blood cell aggregation and oxygenation

    Science.gov (United States)

    Hysi, Eno; Saha, Ratan K.; Kolios, Michael C.

    2012-12-01

    Red blood cell (RBC) aggregation and oxygenation are important markers for a variety of blood disorders. No current technique is capable of simultaneously measuring aggregation/oxygenation levels noninvasively. We propose using photoacoustic ultrasound spectroscopy (PAUS) for assessing both phenomena. This technique relies on frequency-domain analysis of the PA signals by extracting parameters such as the ultrasound spectral slope and the midband fit. To investigate the effect of hematocrit, aggregation, and oxygenation levels on PAUS parameters, a Monte Carlo-based theoretical model and an experimental protocol using porcine RBCs were developed. The samples were illuminated at 750 and 1064 nm and changes in the PAUS parameters were compared to the oxygen-dependent optical absorption coefficients to assess the oxygenation level. Good agreement between the theoretical and experimental spectral parameters was obtained for the spectral slope of the nonaggregated spectra (˜0.3 dB/MHz). The experimental midband fit increased by ˜5 dB for the largest aggregate size. Based on the analysis of the PA signals, the oxygen saturation level of the most aggregated sample was >20% greater than the nonaggregated sample. The results provide a framework for using PA signals' spectroscopic parameters for monitoring the aggregation and oxygenation levels of RBCs.

  9. Biocompatibility evaluation of magnetosomes formed by Acidithiobacillus ferrooxidans

    Energy Technology Data Exchange (ETDEWEB)

    Yan Lei [Institute of Microbiology, School of Life Sciences, Lanzhou University, Lanzhou, 730000 (China); College of Life Science and Technology, Heilongjiang Bayi Agricultural University, Daqing, 163319 (China); Yue Xiaoxuan [Institute of Microbiology, School of Life Sciences, Lanzhou University, Lanzhou, 730000 (China); Zhang Shuang [College of Life Science and Technology, Heilongjiang Bayi Agricultural University, Daqing, 163319 (China); Chen Peng [Institute of Microbiology, School of Life Sciences, Lanzhou University, Lanzhou, 730000 (China); GIBT, Gansu Institute of Business and Technology, Yannan Road 18, Lanzhou, 730010 (China); Xu Zhiliang; Li Yang [Institute of Microbiology, School of Life Sciences, Lanzhou University, Lanzhou, 730000 (China); Li Hongyu, E-mail: hekouyanlei@gmail.com [Institute of Microbiology, School of Life Sciences, Lanzhou University, Lanzhou, 730000 (China)

    2012-10-01

    Magnetite nanocrystal has been extensively used in biomedical field. Currently, an interesting alternative to synthetic magnetic Fe{sub 3}O{sub 4} nanoparticles, called magnetosome, has been found in magnetotactic bacteria. It has been reported that Acidithiobacillus ferrooxidans (At. ferrooxidans) has a potential to synthesize magnetosome. In this study, transmission electron microscope (TEM) was used to analyze the magnetite particles in At. ferrooxidans BY-3. The magnetosomes formed by this bacterium were isolated by a method combining ultracentrifugation and magnetic separation. Crystalline phase and surface functional group of the magnetosomes were investigated by X-ray diffraction (XRD) and Fourier transform infrared spectroscopy (FTIR), respectively. Biocompatibility of the magnetosomes was systematically evaluated at various concentrations (0.5, 1.0, 2.0 and 4.0 mg/ml). MTT test, hemolysis assay and Micronucleus Test were carried out to evaluate in vitro cytotoxicity, blood toxicity and genotoxicity of magnetosomes, respectively. Under these conditions, magnetosomes showed no cytotoxic, genotoxic and hemolytic effects up to 4.0 mg/ml indicating good biocompatibility of these biological nanoparticles. These revealed that the magnetosomes might have a potential for biotechnological and biomedical applications in the future. - Highlights: Black-Right-Pointing-Pointer The production of magnetosomes from At. ferrooxidans has been easily available. Black-Right-Pointing-Pointer Several techniques are used to characterize properties of the magnetosomes. Black-Right-Pointing-Pointer The magnetosomes have no cytotoxicity, no hemolysis activity and no genotoxicity.

  10. Difficulties in assessing brain death in a case of benzodiazepine poisoning with persistent cerebral blood flow.

    Science.gov (United States)

    Marrache, Frédéric; Mégarbane, Bruno; Pirnay, Stéphane; Rhaoui, Abdel; Thuong, Marie

    2004-10-01

    Assessing brain death may sometimes be difficult, with isoelectric EEG following psychotrope overdoses or normal cerebral blood flow (CBF) persisting despite brain death in the case of ventricular drainage or craniotomy. A 42-year-old man, resuscitated after cardiac arrest following a suicidal ingestion of ethanol, bromazepam and zopiclone, was admitted in deep coma. On day 4, his brainstem reflexes and EEG activity disappeared. On day 5, his serum bromazepam concentration was 817 ng/ml (therapeutic: 80-150). The patient was unresponsive to 1 mg of flumazenil. MRI showed diffuse cerebral swelling. CBF assessed by angiography and Doppler remained normal and EEG isoelectric until he died on day 8 with multiorgan failure. There was a discrepancy between the clinically and EEG-assessed brain death, and CBF persistence. We hypothesized that brain death, resulting from diffuse anoxic injury, may lead, in the absence of major intracranial hypertension, to angiographic misdiagnoses. Therefore, EEG remains useful to assess diagnosis in such unusual cases.

  11. A capillary viscometer designed for the characterization of biocompatible ferrofluids

    Energy Technology Data Exchange (ETDEWEB)

    Nowak, J., E-mail: johannes.nowak@tu-dresden.de; Odenbach, S.

    2016-08-01

    Suspensions of magnetic nanoparticles are receiving a growing interest in biomedical research. These ferrofluids can, e.g., be used for the treatment of cancer, making use of the drug targeting principle or using an artificially induced heating. To enable a safe application the basic properties of the ferrofluids have to be well understood, including the viscosity of the fluids if an external magnetic field is applied. It is well known that the viscosity of ferrofluids rises if a magnetic field is applied, where the rise depends on shear rate and magnetic field strength. In case of biocompatible ferrofluids such investigations proved to be rather complicated as the experimental setup should be close to the actual application to allow justified predictions of the effects which have to be expected. Thus a capillary viscometer, providing a flow situation comparable to the flow in a blood vessel, has been designed. The glass capillary is exchangeable and different inner diameters can be used. The range of the shear rates has been adapted to the range found in the human organism. The application of an external magnetic field is enabled with two different coil setups covering the ranges of magnetic field strengths required on the one hand for a theoretical understanding of particle interaction and resulting changes in viscosity and on the other hand for values necessary for a potential biomedical application. The results show that the newly designed capillary viscometer is suitable to measure the magnetoviscous effect in biocompatible ferrofluids and that the results appear to be consistent with data measured with rotational rheometry. In addition, a strong change of the flow behaviour of a biocompatible ferrofluid was proven for ranges of the shear rate and the magnetic field strength expected for a potential biomedical application. - Highlights: • A capillary viscometer to characterize biocompatible ferrofluids is presented. • Shear rates and capillary diameters

  12. Plasmonic biocompatible silver-gold alloyed nanoparticles.

    Science.gov (United States)

    Sotiriou, Georgios A; Etterlin, Gion Diego; Spyrogianni, Anastasia; Krumeich, Frank; Leroux, Jean-Christophe; Pratsinis, Sotiris E

    2014-11-14

    The addition of Au during scalable synthesis of nanosilver drastically minimizes its surface oxidation and leaching of toxic Ag(+) ions. These biocompatible and inexpensive silver-gold nanoalloyed particles exhibit superior plasmonic performance than commonly used pure Au nanoparticles, and as such these nanoalloys have great potential in theranostic applications.

  13. Study of biocompatible and biological materials

    CERN Document Server

    Pecheva, Emilia

    2017-01-01

    The book gives an overview on biomineralization, biological, biocompatible and biomimetic materials. It reveals the use of biomaterials alone or in composites, how their performance can be improved by tailoring their surface properties by external factors and how standard surface modification techniques can be applied in the area of biomaterials to beneficially influence their growth on surfaces.

  14. Assessment of differential pulmonary blood flow using perfusion magnetic resonance imaging: comparison with radionuclide perfusion scintigraphy.

    Science.gov (United States)

    Molinari, Francesco; Fink, Christian; Risse, Frank; Tuengerthal, Siegfried; Bonomo, Lorenzo; Kauczor, Hans-Ulrich

    2006-08-01

    We sought to assess the agreement between lung perfusion ratios calculated from pulmonary perfusion magnetic resonance imaging (MRI) and those calculated from radionuclide (RN) perfusion scintigraphy. A retrospective analysis of MR and RN perfusion scans was conducted in 23 patients (mean age, 60 +/- 14 years) with different lung diseases (lung cancer = 15, chronic obstructive pulmonary disease = 4, cystic fibrosis = 2, and mesothelioma = 2). Pulmonary perfusion was assessed by a time-resolved contrast-enhanced 3D gradient-echo pulse sequence using parallel imaging and view sharing (TR = 1.9 milliseconds; TE = 0.8 milliseconds; parallel imaging acceleration factor = 2; partition thickness = 4 mm; matrix = 256 x 96; in-plane spatial resolution = 1.87 x 3.75 mm; scan time for each 3D dataset = 1.5 seconds), using gadolinium-based contrast agents (injection flow rate = 5 mL/s, dose = 0.1 mmol/kg of body weight). The peak concentration (PC) of the contrast agent bolus, the pulmonary blood flow (PBF), and blood volume (PBV) were computed from the signal-time curves of the lung. Left-to-right ratios of pulmonary perfusion were calculated from the MR parameters and RN counts. The agreement between these ratios was assessed for side prevalence (sign test) and quantitatively (Deming-regression). MR and RN ratios agreed on side prevalence in 21 patients (91%) with PC, in 20 (87%) with PBF, and in 17 (74%) with PBV. The MR estimations of left-to-right perfusion ratios correlated significantly with those of RN perfusion scans (P lung. Further studies in a larger group of patients are required to fully confirm the clinical suitability of this imaging method.

  15. Assessment of ABO blood grouping and secretor status in the saliva of the patients with oral potentially malignant disorders.

    Science.gov (United States)

    Rai, Pragati; Acharya, Swetha; Hallikeri, Kaveri

    2015-01-01

    Secretor status may possibly be one of the factors in the etiopathogenesis of oral precancerous lesions and subsequently cancer. Studies have shown the relationship between the pathogenesis of disease and secretor status. They have made known that secretor status is a possible factor influencing disease status. Studies have revealed the association between blood groups and specific diseases. To assess any association of ABO blood grouping with oral potentially malignant disorders (OPMDs) and to examine whether there is any difference in the saliva secretor status in the patients with OPMDs and healthy controls. The study consisted of 90 subjects, with 45 patients assigned to two groups (a) Patients with potentially malignant disorders and (b) healthy controls. ABO blood grouping was done and 1 ml of unstimulated saliva was collected in a sterile test tube. The Wiener agglutination test was performed to analyze the secretor status in both the groups. Chi-square test and odd ratio were used to assess the relationship between ABO blood group and OPMDs. Chi-square test was performed to assess the relationship between secretor status and OPMDs. Probability level was fixed at ABO blood groups and OPMDs (P > 0.05). The study confirms the inability to secrete blood group antigens in the saliva of patients with OPMDs which could be regarded as a host risk factor. Results could not propose a relationship between ABO blood group and OPMDs.

  16. CLINICAL ASSESSMENT OF FUNCTIONAL OUTCOME IN LATERAL EPICONDYLITIS MANAGED BY LOCAL INFILTRATION OF AUTOLOGOUS BLOOD

    Directory of Open Access Journals (Sweden)

    Dr. Ajay Bharti

    2010-01-01

    Full Text Available Lateral epicondylitis is a well known elbow disorder known to affect a variety of population. Though the disorder is expected to affect a lot of sports personnel, the incidence is not uncommon in persons of household activities. The management comprises of conservative to operative with a dilemma of what to be done in most of the affected population. A large number of interventions have been tried to delineate the best modality but none of them proved to be conclusive. The aim of the present study was to prove the efficacy of cheapest possible interventional modality autologous blood for treatment of Lateral Epicondylitis. Twenty five patients of Tennis elbow were included in this study who have attended the OPD of GSVM Medical College and associated LLR Hospital, Kanpur from November 2007 to April 2008 and fulfilled inclusion and exclusion criteria. 78% were females, mostly housewives involved in regular household activities. All the patients were infiltrated autologous blood with local anaesthetic infiltration. Patients were deprived of regular activities for 3 weeks after infiltration. Follow up was done at weekly interval for 2 weeks and then at 6th week and 12th week. Assessment was done using Visual Analogue Scale ( VAS and Verhaar et al scoring system. Total follow up period was 3 months. We observed that the mean VAS score improved from preinfiltrative 6.40±1.22 to 0.48±1.53 with p value being < .001. 64% patients showed excellent results and 32% showed good results as per Verhaar et al scoring system on 12 weeks follow up. One patient did not respond to this procedure and showed poor result as per Verhaar et al score. Therefore, autologous blood infiltration is a safe and effective modality in treatment of Lateral Epicondylitis.

  17. Assessment of persistent organic pollutants levels in blood samples from Quintana Roo, Mexico.

    Science.gov (United States)

    Antonio, Trejo-Acevedo; Edith, Rivero-Pérez Norma; Rogelio, Flores-Ramírez; Fernando, Díaz-Barriga; Catalina, Ochoa Angeles; Nelinho, Pérez-Maldonado Iván

    2013-06-01

    The Stockholm Convention on persistent organic pollutants (POPs) sought to determine baseline exposures to POPs in the general population; however, in developing countries, exposure to these chemicals in hot spots may be an issue of public health considering its magnitude. Therefore, the aim of this study was to assess the levels of POPs in the blood of children living in three communities in the Southeastern Region of Mexico. During 2007, we studied a total of 96 healthy children (aged 6-12 years). Quantitative analyses were performed using gas chromatography coupled with mass spectrometry. High levels of p,p'-DDT and its principal metabolite, p,p'-DDE, were found in the blood of children living in the three communities studied, the levels ranged from 463.5 to 9046.3 ng/g lipid and from 490.8 to 57,712.4 ng/g lipid for DDT and DDE, respectively. In addition, high levels of lindane (γ-HCH) were found, with mean levels ranging between 575.4 and 6580.6 ng/g lipid. Moreover, children living in the study region were also exposed to polychlorinated biphenyls (PCBs), and the levels of these compounds in the blood of children were very similar between the communities with mean levels of around 3000 ng/g lipid (total PCBs). In conclusion, we demonstrated that children living in the studied communities were exposed to complex chemical mixtures (DDT, DDE, lindane and PCBs) rather than to individual compounds. Therefore, in future studies it is important to understand the potential interactions between the components of these mixtures. Copyright © 2012 Elsevier GmbH. All rights reserved.

  18. Patients' confidence in methods of blood pressure assessment and their reported adherence to antihypertensive medications.

    Science.gov (United States)

    Alvarez, Paul; Zeng, Jennifer; Tuttle, Laura; Viera, Anthony J

    2017-10-01

    Adherence to antihypertensive medications is often less than optimal. Research suggests that patients have limited confidence regarding whether office blood pressure (BP) assessments represent their 'true' BP, which may further promote poor adherence to BP-lowering medication. We assessed peoples' confidence in the methods of BP assessment and examined the associations between patients' confidence levels and medication adherence comparing office and home BP-monitoring techniques. We surveyed US adults aged 30 years or older (N=1010), all of whom had undergone an office BP measurement within the past 6 months. Respondents who indicated being prescribed antihypertensive medication (N=429) were asked to indicate their level of confidence on a 1-9 scale that BP measurements represented their true BP, and their adherence to antihypertensive medication using the eight-item Morisky Medical Adherence Scale (MMAS-8). Respondents had equal confidence that both office BP measurements and home monitoring measurements reflected their true BP (median=7). Respondents indicated that they would have slightly more confidence in ambulatory BP monitoring (median=8). As respondents' confidence in the assessments of BP from office measurements and home monitoring increased from 1 to 9, the mean MMAS-8 score, adjusted for age, race, and education, increased from 5.38 to 6.25 (P=0.053) and from 5.50 to 6.14 (P=0.25), respectively. As patients' confidence in a BP assessment method increases, so too does their reported adherence to prescribed antihypertensive medications. This finding further supports the incorporation of methods in which patients can feel confident that the measurements are representative of their 'true' BP.

  19. Blood oxygen-level dependent functional assessment of cerebrovascular reactivity: Feasibility for intraoperative 3 Tesla MRI.

    Science.gov (United States)

    Fierstra, Jorn; Burkhardt, Jan-Karl; van Niftrik, Christiaan Hendrik Bas; Piccirelli, Marco; Pangalu, Athina; Kocian, Roman; Neidert, Marian Christoph; Valavanis, Antonios; Regli, Luca; Bozinov, Oliver

    2017-02-01

    To assess the feasibility of functional blood oxygen-level dependent (BOLD) MRI to evaluate intraoperative cerebrovascular reactivity (CVR) at 3 Tesla field strength. Ten consecutive neurosurgical subjects scheduled for a clinical intraoperative MRI examination were enrolled in this study. In addition to the clinical protocol a BOLD sequence was implemented with three cycles of 44 s apnea to calculate CVR values on a voxel-by-voxel basis throughout the brain. The CVR range was then color-coded and superimposed on an anatomical volume to create high spatial resolution CVR maps. Ten subjects (mean age 34.8 ± 13.4; 2 females) uneventfully underwent the intraoperative BOLD protocol, with no complications occurring. Whole-brain CVR for all subjects was (mean ± SD) 0.69 ± 0.42, whereas CVR was markedly higher for tumor subjects as compared to vascular subjects, 0.81 ± 0.44 versus 0.33 ± 0.10, respectively. Furthermore, color-coded functional maps could be robustly interpreted for a whole-brain assessment of CVR. We demonstrate that intraoperative BOLD MRI is feasible in creating functional maps to assess cerebrovascular reactivity throughout the brain in subjects undergoing a neurosurgical procedure. Magn Reson Med 77:806-813, 2017. © 2016 International Society for Magnetic Resonance in Medicine. © 2016 International Society for Magnetic Resonance in Medicine.

  20. Toward laboratory blood test-comparable photometric assessments for anemia in veterinary hematology

    Science.gov (United States)

    Kim, Taehoon; Choi, Seung Ho; Lambert-Cheatham, Nathan; Xu, Zhengbin; Kritchevsky, Janice E.; Bertin, Francois-René; Kim, Young L.

    2016-10-01

    Anemia associated with intestinal parasites and malnutrition is the leading cause of morbidity and mortality in small ruminants worldwide. Qualitative scoring of conjunctival redness has been developed so that farmers can gauge anemia in sheep and goats to identify animals that require treatment. For clinically relevant anemia diagnosis, complete blood count-comparable quantitative methods often rely on complicated and expensive optical instruments, requiring detailed spectral information of hemoglobin. We report experimental and numerical results for simple, yet reliable, noninvasive hemoglobin detection that can be correlated with laboratory-based blood hemoglobin testing for anemia diagnosis. In our pilot animal study using calves, we exploit the third eyelid (i.e., palpebral conjunctiva) as an effective sensing site. To further test spectrometer-free (or spectrometerless) hemoglobin assessments, we implement full spectral reconstruction from RGB data and partial least square regression. The unique combination of RGB-based spectral reconstruction and partial least square regression could potentially offer uncomplicated instrumentation and avoid the use of a spectrometer, which is vital for realizing a compact and inexpensive hematology device for quantitative anemia detection in the farm field.

  1. Assessment of a continuous blood gas monitoring system in animals during circulatory stress

    Directory of Open Access Journals (Sweden)

    Renzulli Attilio

    2011-01-01

    Full Text Available Abstract Background The study was aimed to determine the measurement accuracy of The CDI™ blood parameter monitoring system 500 (Terumo Cardiovascular Systems Corporation, Ann Arbor MI in the real-time continuous measurement of arterial blood gases under different cardiocirculatory stress conditions Methods Inotropic stimulation (Dobutamine 2.5 and 5 μg/kg/min, vasoconstriction (Arginine-vasopressin 4, 8 and 16 IU/h, hemorrhage (-10%, -20%, -35%, and -50% of the theoretical volemia, and volume resuscitation were induced in ten swine (57.4 ± 10.7 Kg.Intermittent blood gas assessments were carried out using a routine gas analyzer at any experimental phase and compared with values obtained at the same time settings during continuous monitoring with CDI™ 500 system. The Bland-Altman analysis was employed. Results Bias and precision for pO2 were - 0.06 kPa and 0.22 kPa, respectively (r2 = 0.96; pCO2 - 0.02 kPa and 0.15 kPa, respectively; pH -0.001 and 0.01 units, respectively ( r2 = 0.96. The analysis showed very good agreement for SO2 (bias 0.04,precision 0.33, r2 = 0.95, Base excess (bias 0.04,precision 0.28, r2 = 0.98, HCO3 (bias 0.05,precision 0.62, r2 = 0.92,hemoglobin (bias 0.02,precision 0.23, r2 = 0.96 and K+ (bias 0.02, precision 0.27, r2 = 0.93. The sensor was reliable throughout the experiment during hemodynamic variations. Conclusions Continuous blood gas analysis with the CDI™ 500 system was reliable and it might represent a new useful tool to accurately and timely monitor gas exchange in critically ill patients. Nonetheless, our findings need to be confirmed by larger studies to prove its reliability in the clinical setting.

  2. Hyperventilation-induced reduction in cerebral blood flow: Assessment by positron emission tomography

    Energy Technology Data Exchange (ETDEWEB)

    Bednarczyk, E.M.; Rutherford, W.F.; Leisure, G.P.; Munger, M.A.; Panacek, E.A.; Miraldi, F.D.; Green, J.A. (Case Western Reserve Univ. School of Medicine, Cleveland, OH (USA))

    1990-05-01

    The use of positron emission tomography (PET) has been well documented as a relatively noninvasive method of measuring cerebral blood flow (CBF), both globally and regionally. The utility of readily detecting alterations in CBF is apparent, particularly when applied to the evaluation of therapeutic interventions thought to influence CBF. We report the effects of hypocapnia, an experimental condition of known cerebral vasoconstriction, in ten normal volunteers. Subjects had brain blood flow evaluated utilizing H215O as the positron emitter before and after approximately five minutes of hyperventilation. Baseline CBF was measured as a mean +/- SD of 61.2 +/- 16.3 mL/min/100 g of tissue. Mean baseline arterial blood gas values were PaO2 107.4 +/- 14 mm Hg, PaCO2 37.7 +/- 0.89 mm Hg, and pH 7.39 (calculated from mean (H+)). Post hyperventilation, global CBF was measured as 31.1 +/- 10.8 mL/min/100 g. Mean arterial blood gas values were PaO2 141.7 +/- 21 mm Hg, PaCO2 19.7 +/- 5 mm Hg, and pH 7.63 (calculated from mean (H+)). CBF decreased by a mean of 49.5 +/- 11 percent. Data analysis using the Student's t-test showed a significant change over baseline in PaCO2 (p less than 0.001) and CBF (p less than 0.001), in the hyperventilated state. Correlations were noted between the decrease in CBF and change in PaCO2 (r = 0.81) as well as between hyperventilation PaCO2 and the change in CBF (r = 0.97). We conclude that, as measured by PET, CBF decreases significantly during a state of artificial hyperventilation to a degree consistent with results seen using other methods. PET appears to be a valuable tool in the assessment of interventions that could influence CBF.

  3. Biocompatibility and Surface Studies of Microwave CVD Diamond Films

    Science.gov (United States)

    Davis, Brian; Garguilo, J. M.; Koeck, F. A. M.; Nemanich, R. J.; Price, K. J.

    2002-03-01

    The structure and surface properties of a variety of diamond and diamond like carbon films were studied at the nano-scale, in an attempt to assess the biocompatibility of these surfaces. The process of microwave chemical vapor deposition was used to deposit undoped diamond, nitrogen doped diamond, diamond with a titanium monolayer, and diamond-like carbon samples. The contact angles of de-ionized water droplets on the surface of the samples were measured to analyze the surface energy of each film. The rms roughness values of the diamond films measured by atomic force microscopy were also used in determining surface characteristics. Surface treatments of hydrogen passivation, and oxidization were applied to the surface of each film. Hydrogen passivation of the undoped diamond, and nitrogen doped diamond surfaces increases the contact angle on average 30 degrees. Oxidation of the surface decreases the contact angle on average 20 degrees. The surface treatments did not significantly change the contact angle of the diamond like carbon films. Protein adsorption is the first event to take place at a tissue/material interface of an implant into the body, and fibrinogen is the major surface protein, which initiates coagulation and inflammation in the body. The adsorption of fibrinogen was used as an indicator of the biocompatibility of these diamond materials. Fibrinogen was applied to the diamond, and diamond like carbon films. A correlation between contact angle/surface energy, roughness, and the fibrinogen adsorption of these diamond surfaces is reported. There was no significant change in the contact angles following the application of fibrinogen to the surface of the films. This could indicate the biocompatibility of the diamond films. This work supported by the NSF REU program at NCSU and a Physical Sciences Student Research grant from MSU.

  4. D-dimer is useful in assessing the vulnerable blood in elderly patients with coronary disease

    Institute of Scientific and Technical Information of China (English)

    Yansong Zheng; Qiang Zeng; Liping Zhang; Liufa Duan; Kunlun He; Qiufu Zheng

    2008-01-01

    Background and objective The value of D-dimer in the risk stratification of patients with coronary artery diseas(CAD)and the relationship between D-dimer and the diseased coronary arteries remains controversial or unclear.especially in the elderly.Thisstudy was to evaluate the usefulness of D-djmer as a biomarker in assessing the vuinerable blood in the elderly patients with coronarydisease.Methods Sixty elderly (≥60 years old)male patients with suspected CAD were enrolled in this prospective study.Patients were divided into CAD group(n=41,10 with stable angina and 31 with unstable angina)and control group(n=19)according to their coronary angiography Results Clinicalinformation including age,body mass index(BMI),smoking index,and thecomplications of Primary hypertension or diabetes.and CAD family history was collected.Venous blood was sampled serially for thedetermination of total cholesterol,HDL cholesterol,LDL cholesterol,triglycerides,apoAl,apoB,glucose,uric acid,homocysteine(Hey),hs-CRP,soluble thrombomodulin(sTM),and marker of fibrinolytic system and hypercoagulability,such as D-dimer,fibrinogen,etc.The extent of coronary atherosclerosis was assessed.using the Gensini scoring system on the basis of coronary angiography.Results Compared with the controls.the patients with CAD had significantly higher levels of D-dimer.D-dimer level wassignificantly correlated to age.hs-CR P.Hcy,and PAI-1.Patients with D-dimer levels in the top triplicate of D-dimer level hadsignificantly higher prevalence of unstable angina compared with patients in the lowest triplicate(OR=4.8,Z=3.28,P=0.001).In anordinal logistic regression.the OR value ofdeveloping more serious CAD augmented 3.1-foid with each increasing triplicate of D-dimer.Patients with unstable angina had a significantly higher level of D-dimer than the controls(P=0.005),and an increasing trend comparedwith patients with stable angina (P=0.059).whereas there was no difference between the patients with stable angina and

  5. Assessment of high blood pressure patients in the third year’s Surgical Clinic of the Dentistry course at Cesumar

    OpenAIRE

    Menin, Cristiane; Bortoloto, Flávia Gongora; Gustavo Jacobucci FARAH; Filho, Liogi Iwaki; Iwaki, Lílian Cristina Vessoni; Leite, Pablo C. Comelli; Gentini, Raquel Forlani

    2007-01-01

    With the increase of arterial hypertension in the Brazilian population, it has become essential to point out to undergraduate students the need for a thorough clinical examination of patients, and the special care with high blood pressure patients, especially in a surgical clinic where complications may be severe. The objective of this work has been to assess the number of high blood pressure patients that come the Surgical Clinic of the Dentistry course of CESUMAR, and find out if these pati...

  6. Regional cerebral blood flow imaging assessment of brain function reconstruction in elderly hemiplegia patients by body weight support treadmill training

    Institute of Scientific and Technical Information of China (English)

    Wenqing Wang; Yongping Liu; Diqing Wang; Yanshuang Li; Jinglai Hao; Hongwei Zhang; Sheng Bi; Changshui Weng

    2011-01-01

    The mechanism underlying body weight support treadmill training in elderly hemiplegic stroke patients is largely unknown. This study aimed to elucidate the changes of cortical blood flow in seven elderly patients with post-stroke hemiplegia before and after body weight support treadmill training by semi-quantitative analysis of regional cerebral blood flow assessed by single photon emission computed tomography. Body weight support treadmill training for 6 months was effective in improving cerebral blood flow and promoting the walking speed and balance recovery in elderly patients with post-stroke hemiplegia.

  7. The biocompatibility evaluation of mPEG-PLGA-PLL copolymer and different LA/GA ratio effects for biocompatibility.

    Science.gov (United States)

    He, Zelai; Wang, Qi; Sun, Ying; Shen, Ming; Zhu, Mingjie; Gu, Malin; Wang, Yi; Duan, Yourong

    2014-01-01

    Biomaterial poly(lactic-co-glycolic acid) (PLGA), a FDA-approved material for clinical application, showed broad prospects in the past, but gradually can no longer meet present clinical developments and requirements, which we synthesized monomethoxy(polyethylene glycol)-poly(D,L-lactic-co-glycolic acid)-poly(L-lysine) (mPEG-PLGA-PLL) (PEAL) and have had some relevant reports. But studies on biocompatibility and the impacts of LA and GA ratio (LA/GA=60/40, 70/30, and 80/20) in main material have not yet been reported. Hemolysis experiment indicates that the hemolysis rate of PEAL extraction medium is less than 5%. Whole blood clotting time (CT), plasma recalcification time, activated partial thromboplastin time, prothrombin time evaluations, and dynamic CT assay show that the anticoagulant time of PEAL copolymer for blood is longer than that under negative and positive control. Protein adsorption assay indicates that PEAL films adsorb less protein than PLGA films (p0.05). Complement activation test shows that PEAL surface does not induce complement activation. CCK8 measurement shows that the relative growth rates of Huh7, L02, and L929 cells co-incubated with PEAL nanoparticles (NPs) are more than 90%. PEAL NPs co-incubated with 5% foetal bovine serum or 2% bovine serum albumin, through dynamic light scattering assay, remain stable. Different concentrations of PEAL NPs co-incubated with zebrafish embryos at 6-72 h post fertilization show that comparing with negative control, 10, 100, or 500 μM of NPs for embryos development has no significant effects (p>0.05), only 1000 or 2000 μM of NPs has some effects (p<0.05). It is concluded that the PEAL copolymer, with excellent biocompatibility, proves to be a high-safety dose as drug carrier and implant candidate in vivo.

  8. Biodegradation and in vivo biocompatibility of rosin: a natural film-forming polymer.

    Science.gov (United States)

    Satturwar, Prashant M; Fulzele, Suniket V; Dorle, Avinash K

    2003-10-22

    The specific aim of the present study was to investigate the biodegradation and biocompatibility characteristics of rosin, a natural film-forming polymer. Both in vitro as well as in vivo methods were used for assessment of the same. The in vitro degradation of rosin films was followed in pH 7.4 phosphate buffered saline at 37 degrees C and in vivo by subdermal implantation in rats for up to 90 days. Initial biocompatibility was followed on postoperative days 7, 14, 21, and 28 by histological observations of the surrounding tissues around the implanted films. Poly (DL-lactic-co-glycolic acid) (PLGA) (50:50) was used as reference material for biocompatibility. Rate and extent of degradation were followed in terms of dry film weight loss, molecular weight (MW) decline, and surface morphological changes. Although the rate of in vitro degradation was slow, rosin-free films showed complete degradation between 60 and 90 days following subdermal implantation in rats. The films degraded following different rates, in vitro and in vivo, but the mechanism followed was primarily bulk degradation. Rosin films demonstrated inflammatory reactions similar to PLGA, indicative of good biocompatibility. Good biocompatibility comparable to PLGA is demonstrated by the absence of necrosis or abscess formation in the surrounding tissues. The study provides valuable insight, which may lead to new applications of rosin in the field of drug delivery.

  9. The 2015 Canadian Hypertension Education Program recommendations for blood pressure measurement, diagnosis, assessment of risk, prevention, and treatment of hypertension.

    Science.gov (United States)

    Daskalopoulou, Stella S; Rabi, Doreen M; Zarnke, Kelly B; Dasgupta, Kaberi; Nerenberg, Kara; Cloutier, Lyne; Gelfer, Mark; Lamarre-Cliche, Maxime; Milot, Alain; Bolli, Peter; McKay, Donald W; Tremblay, Guy; McLean, Donna; Tobe, Sheldon W; Ruzicka, Marcel; Burns, Kevin D; Vallée, Michel; Ramesh Prasad, G V; Lebel, Marcel; Feldman, Ross D; Selby, Peter; Pipe, Andrew; Schiffrin, Ernesto L; McFarlane, Philip A; Oh, Paul; Hegele, Robert A; Khara, Milan; Wilson, Thomas W; Brian Penner, S; Burgess, Ellen; Herman, Robert J; Bacon, Simon L; Rabkin, Simon W; Gilbert, Richard E; Campbell, Tavis S; Grover, Steven; Honos, George; Lindsay, Patrice; Hill, Michael D; Coutts, Shelagh B; Gubitz, Gord; Campbell, Norman R C; Moe, Gordon W; Howlett, Jonathan G; Boulanger, Jean-Martin; Prebtani, Ally; Larochelle, Pierre; Leiter, Lawrence A; Jones, Charlotte; Ogilvie, Richard I; Woo, Vincent; Kaczorowski, Janusz; Trudeau, Luc; Petrella, Robert J; Hiremath, Swapnil; Stone, James A; Drouin, Denis; Lavoie, Kim L; Hamet, Pavel; Fodor, George; Grégoire, Jean C; Fournier, Anne; Lewanczuk, Richard; Dresser, George K; Sharma, Mukul; Reid, Debra; Benoit, Geneviève; Feber, Janusz; Harris, Kevin C; Poirier, Luc; Padwal, Raj S

    2015-05-01

    The Canadian Hypertension Education Program reviews the hypertension literature annually and provides detailed recommendations regarding hypertension diagnosis, assessment, prevention, and treatment. This report provides the updated evidence-based recommendations for 2015. This year, 4 new recommendations were added and 2 existing recommendations were modified. A revised algorithm for the diagnosis of hypertension is presented. Two major changes are proposed: (1) measurement using validated electronic (oscillometric) upper arm devices is preferred over auscultation for accurate office blood pressure measurement; (2) if the visit 1 mean blood pressure is increased but blood pressure measurements using ambulatory blood pressure monitoring (preferably) or home blood pressure monitoring should be performed before visit 2 to rule out white coat hypertension, for which pharmacologic treatment is not recommended. A standardized ambulatory blood pressure monitoring protocol and an update on automated office blood pressure are also presented. Several other recommendations on accurate measurement of blood pressure and criteria for diagnosis of hypertension have been reorganized. Two other new recommendations refer to smoking cessation: (1) tobacco use status should be updated regularly and advice to quit smoking should be provided; and (2) advice in combination with pharmacotherapy for smoking cessation should be offered to all smokers. The following recommendations were modified: (1) renal artery stenosis should be primarily managed medically; and (2) renal artery angioplasty and stenting could be considered for patients with renal artery stenosis and complicated, uncontrolled hypertension. The rationale for these recommendation changes is discussed.

  10. Clinical effects of a polyethylene glycol grafted cellulose membrane on thrombogenicity and biocompatibility during hemodialysis.

    Science.gov (United States)

    Akizawa, T; Kino, K; Kinugasa, E; Koshikawa, S; Ikada, Y; Kishida, A; Hatanaka, Y; Imamura, K

    1990-01-01

    The biocompatibility and thrombogenicity of polyethylene-glycol (PEG)-grafted cellulose hemodialysis (HD) membranes (PEGC) were investigated in cross-over HD of five HD patients with ordinary cellulose (OC). The PEGC significantly suppressed transient leukocyte and thrombocytopenia, and release of C3a, beta-thromboglobulin and platelet factor 4, in corresponding with the quantity of grafted PEG. HD with PEGC resulted in lower granulocyte elastase production, protein and blood cells adsorption on the membrane surface than those with OC. Minimum heparin in HD with PEGC was three times lower than that with OC, with the thrombin-antithrombin III complex elevation lower than that in HD with OC. The results indicate that the grafted PEG effectively suppresses blood and membrane interaction, thus improving biocompatibility and reducing thrombogenicity in clinical HD.

  11. Storage and use of Newborn Screening Blood Specimens for Research: Assessing Public Opinion in Illinois.

    Science.gov (United States)

    Hart, Alexa; Petros, Michael; Charrow, Joel; Nash, Claudia; Wicklund, Catherine

    2015-06-01

    Storage and use of residual dried blood spots (DBS) from newborn screening (NBS) for research purposes has been a topic of elevated interest following high profile disputes between genetic privacy advocacy groups and state NBS programs. Our objective was to assess public opinion in Illinois regarding storage and use of residual DBS for research. Five hundred twenty-six Illinois residents completed a survey assessing attitudes about research uses for DBS, storage length, and consent issues. Over 80 % of respondents expressed agreement with questions regarding research uses of DBS. Eighty-three percent of respondents were in favor of storage for at least one year with 44 % favoring indefinite storage. Respondents with higher educational attainment were more likely to support research use of DBS and less likely to desire contact for each future study (P research or to favor long-term storage (P public health program. Trust in the public health service of NBS must be protected through transparency in the policy process.

  12. Assessment of acetylcholinesterase and butyrylcholinesterase activities in blood plasma of agriculture workers

    Directory of Open Access Journals (Sweden)

    V Dhananjayan

    2012-01-01

    Full Text Available Background: Cholinesterase determination indicates whether the person has been under pesticide exposure is not. It is recommended that the worker′s cholinesterase level should be assessed for workers at a pesticide applied region. Hence, cholinesterase activities in blood samples of agricultural workers exposed to vegetables and grape cultivation with age matched, unexposed workers, who never had any exposure to pesticides, were estimated. Methods: The detailed occupational history and lifestyle characters were obtained by questionnaire. Cholinesterase activity was determined by the method of Ellman as modified by Chambers and Chambers. Results: AChE was ranging from 1.65 to 3.54μmoles/min/ml in exposed subjects where as it was ranged from 2.22 to 3.51μmoles/min/ml in control subjects. BChE activity was ranging from 0.16 to 5.2μmoles/min/ml among exposed subjects, where as it was ranged from 2.19 to 5.06μmoles/min/ml in control subjects. The results showed statistically significant reduction in enzyme activities (AChE 14%; BChE 56% among exposed subjects. Conclusion: It was concluded that the reduction in cholinesterase activity may lead to varieties of effects. Hence it is compulsory to use protective gadgets during pesticide spray. Further a continuous biomonitoring study is recommended to assess pesticide exposure.

  13. Biocompatibility of photopolymers for additive manufacturing

    Directory of Open Access Journals (Sweden)

    Leonhardt Stefan

    2016-09-01

    Full Text Available To establish photopolymers for the production of class II or class III medical products by additive manufacturing it is essential to know which components of photopolymeric systems, consisting of monomers, photoinitiators and additives, are the determining factors on their biocompatible properties. In this study the leachable substances of a cured photopolymeric system were eluted and identified by HPLC-MS detection. In addition the cured photopolymer was testes for cytotoxicity and genotoxicity according to DIN EN ISO 10993 for long time applications. The results showed that uncured residual monomers are the determining factor on the biocompatible properties of the photopolymeric system. Strategies to reduce these residual monomers in the cured photopolymer are presented.

  14. In vivo MRI biocompatibility evaluation of functionalized carbon fibers in reaction with soft tissues

    Directory of Open Access Journals (Sweden)

    Prokić B.B.

    2012-01-01

    Full Text Available In modern medicine implants are very important and so is their design and choice of materials. Almost equally important is the choice of imaging technique used to in vivo monitor their fate and biocompatibility. The aim of this study was to evaluate the ability of magnetic resonance imaging (MRI in monitoring the biocompatibility of two newly designed carbon fibers. We have analyzed the interaction of surface functionalized carbon fibers (basic and acidic with muscle and subcutaneous tissues of rabbits. MRI techniques showed to be useful in longitudinal monitoring of the surrounding tissues, assessment of biocompatibility of new implants, and in the distinction of in vivo surgical edema from inflammation. Histopathology confirmed MRI results, thus showing that MRI has a great potential for in vivo studies of such materials. [Projekat Ministarstva nauke Republike Srbije, br. III 45006 and III 41005

  15. Characterization and Biocompatibility of Biopolyester Nanofibers

    OpenAIRE

    Tang Hui Ying; Tetsuji Yamaoka; Tadahisa Iwata; Daisuke Ishii

    2009-01-01

    Biodegradable nanofibers are expected to be promising scaffold materials for biomedical engineering, however, biomedical applications require control of the degradation behavior and tissue response of nanofiber scaffolds in vivo. For this purpose, electrospun nanofibers of poly(hydroxyalkanoate)s (PHAs) and poly(lactide)s (PLAs) were subjected to degradation tests in vitro and in vivo. In this review, characterization and biocompatibility of nanofibers derived from PHAs and PLAs are described...

  16. In vitro biocompatibility testing of some synthetic polymers used for the achievement of nervous conduits

    OpenAIRE

    Mihai, R; Florescu, IP; Coroiu, V; Oancea, A.; Lungu, M.

    2011-01-01

    Biocompatible synthetic polymers are largely used in the bio–medical domain, tissue engineering and in controlled release of medicines. Polymers can be used in the achievement of cardiac and vascular devices, mammary implants, eye lenses, surgical threads, nervous conduits, adhesives, blood substitutes, etc. Our study was axed on the development of cytotoxicity tests for 3 synthetic polymers, namely polyvinyl alcohol, polyethylene glycol and polyvinyl chloride. These tests targeted to determi...

  17. Assessment of a five-color flow cytometric assay for verifying automated white blood cell differentials

    Institute of Scientific and Technical Information of China (English)

    HUANG Chun-mei; YU Lian-hui; PU Cheng-wei; WANG Xin; WANG Geng; SHEN Li-song; WANG Jian-zhong

    2013-01-01

    Background White blood cell (WBC) counts and differentials performed using an automated cell counter typically require manual microscopic review.However,this last step is time consuming and requires experienced personnel.We evaluated the clinical efficiency of using flow cytometry (FCM) employing a six-antibody/five-color reagent for verifying automated WBC differentials.Methods A total of 56 apparently healthy samples were assessed using a five-color flow cytometer to verify the normal reference ranges of WBC differentials.WBC differentials of 622 samples were also determined using both a cell counter and FCM.These results were then confirmed using manual microscopic methods.Results The probabilities for all of the parameters of WBC differentials exceeded the corresponding normal reference ranges by no more than 7.5%.The resulting WBC differentials were well correlated between FCM and the cell counter (r >0.88,P <0.001),except in the case of basophils.Neutrophils,lymphocytes,and eosinophils were well correlated between FCM and standard microscopic cytology assessment (r >0.80,P <0.001).The sensitivities of FCM for identification of immature granulocytes and blast cells (72.03% and 22.22%,respectively) were higher than those of the cell counter method (44.92% and 11.11%,respectively).The specificities of FCM were all above 85%,substantially better than those of the cell counter method.Conclusion These five-color FCM assays could be applied to accurately verify abnormal results of automated assessment of WBC differentials.

  18. [Assessment at distance of a self-measurement of blood pressure education program: The PEA].

    Science.gov (United States)

    Atallah, A; Pham Hoang Minh, A; Billy-Brissac, R; Dinarque, C

    2015-06-01

    Current recommendations advocate self-measurement of blood pressure (SMBP) for the diagnosis and monitoring of high blood pressure (HBP). The "PEA" is an education program of the HTA GWAD network. Its mission is to train hypertensive patients with SMBP. The objective of this study is to evaluate between 6 months to 1 year after the efficiency of this program on the theoretical and practical knowledge of patients, as well as their behavior towards hypertension. Hundred and twenty patients were included in the study. In an interview, their knowledge was assessed using a questionnaire. The acquisition of the technique, reading and figures transcription, purchase of a SMBP device were also evaluated. The average questionnaire score was 5.7/13 (σ=2.7) before the educational session, 9.5/13 (σ=1.9) 1 week after the educational session. This improvement persisted over time with 8.9/13 (σ=2.9) correct answers 6 months to 1 year later. Exactly 73.3% (n=88/120) had a self-measurement device. Among them, 44.3% (n=39/88) practiced SMBP before medical consultations and 10% systematically did it before each medical consultation. A number of 84.2% (n=101/120) mastered the technique and 76.7% (n=92/120) of patients knew how to transcribe figures. Reading and understanding figures were acquired by 61.7% (n=74/120) of patients. A high level of education was correlated with a high level of practice. PEA is a sustainable solid and stable education program. However, the practice of SMBP is not yet systematic and remains to be encouraged in some patients. Given this situation, the network offers improvements in its program: highlighting of objectives, calendar reminder, "coaching" nurse.

  19. Assessing the Nutritional Status and Blood Glutathione Level for Preschool Children

    Directory of Open Access Journals (Sweden)

    Hanaa H. Elsayed * and Amr Abd El-Hafez

    2006-12-01

    Full Text Available This study was designed to assessment nutrition status and blood glutathione (GSH level for preschool children. Subjects and methods: The study included 70 (boys and girls preschool children at aged from 2-5 years. Children was randomly selected from the out patients clinic at the National Nutrition Institute Cairo. Weigh and height were measured for them to evaluate the effect of nutrients on bodies, dietary intake was collected for the children were subjected to estimation of (Energy, Protein, Fat, Carbohydrate, vitamins A, folic acid and minerals iron, zinc and selenium in their daily diet. Blood samples were collected to determine hemoglobin, glutathione and total protein concentration. Results: The dietary analysis showed that, every nutrient was lower than the requirement except total protein was higher than the recommend. Stunting showed (25.5% of boys and (20% of girls, underweight (23% of boys and 14% of girls were the problems among preschool children. A glutathione deficiency was found among 97% of boys and 100% of girls. The hemoglobin ratio 77.1% from children was equal or less than normal concentration. Total protein noticed 82.9% of boys and 85.7 of girls in normal value. Conclusion: There was little quantity of nutrients intake, glutathione level and growth. The study can be recommended to improve their daily dietary intake and nutrition habits by education programs for their parents or supplement of studied cases with special ferrous and protein specially contains sulphur amino acids in daily diet to cover Recommended Dietary Allowances and can improve tissue GSH concentration

  20. Assessment of DDT and DDE levels in soil, dust, and blood samples from Chihuahua, Mexico.

    Science.gov (United States)

    Martínez, Fernando Díaz-Barriga; Trejo-Acevedo, Antonio; Betanzos, Angel F; Espinosa-Reyes, Guillermo; Alegría-Torres, Jorge Alejandro; Maldonado, Iván Nelinho Pérez

    2012-02-01

    The aim of this study was to assess levels of DDT and DDE in two environmental matrices (soil and dust) and to investigate the blood levels of these insecticides in exposed children living in a north Mexican state (Chihuahua) where DDT was sprayed several years ago during (1) health campaigns for the control of malaria and (2) agricultural activities. DDT and DDE were analyzed by gas chromatography/mass spectrometry. In general, lower levels were found in household outdoor samples. The levels in outdoor samples ranged from 0.001 to 0.788 mg/kg for DDT and from 0.001 to 0.642 mg/kg for DDE. The levels in indoor samples ranged from 0.001 to 15.47 mg/kg for DDT and from 0.001 to 1.063 mg/kg for DDE. Similar results to those found in indoor soil were found in dust, in which the levels ranged from 0.001 to 95.87 mg/kg for DDT and from 0.001 to 0.797 mg/kg for DDE. Moreover, blood levels showed that all of the communities studied had been exposed to DDT and/or DDE, indicating a general past or present exposure to DDT. It is important to note that the quotient DDT/DDE in all matrices was always >1. Whether the people living in our study area are at risk is an issue that deserves further analysis. However, applying precautionary principles, it is important to initiate a risk-reduction program to decrease exposure to DDT and its metabolites in people living in this area.

  1. Biocompatibility of TiO2 nanotubes with different topographies.

    Science.gov (United States)

    Wang, Yu; Wen, Cuie; Hodgson, Peter; Li, Yuncang

    2014-03-01

    The biological response of osteoblast cells to implant materials depends on the topography and physico-chemistry of the implant surface and this determines the cell behavior such as shaping, adhesion and proliferation, and finally the cell fate. In this study, titanium (Ti) was anodized to create different topographies of titania nanotubes (TNTs) to investigate the cell behavior to them. TNTs with and without a highly ordered nanoporous layer on their top surface were fabricated using two-step and one-step anodizing processes, respectively. The TNTs without a highly ordered nanoporous layer on the top surface exhibited a rougher surface, higher surface energy and better hydrophilicity than the TNTs with such a layer. Osteoblast-like cells (SaOS2) were used to assess the biocompatibility of the TNTs with different topographies in comparison to bare cp-Ti. Results indicated that TNTs can enhance the proliferation and adhesion of osteoblast-like cells. TNTs without a highly ordered nanoporous layer exhibited better biocompatibility than the TNTs covered by such a nanoporous layer. Cell morphology observation using confocal microscopy and SEM indicated that SaOS2 cells that were adhered to the TNTs without the highly ordered nanoporous layer showed the longest filopodia compared to TNTs with a highly ordered nanoporous layer and bare cp-Ti.

  2. Metallic zinc exhibits optimal biocompatibility for bioabsorbable endovascular stents.

    Science.gov (United States)

    Bowen, Patrick K; Guillory, Roger J; Shearier, Emily R; Seitz, Jan-Marten; Drelich, Jaroslaw; Bocks, Martin; Zhao, Feng; Goldman, Jeremy

    2015-11-01

    Although corrosion resistant bare metal stents are considered generally effective, their permanent presence in a diseased artery is an increasingly recognized limitation due to the potential for long-term complications. We previously reported that metallic zinc exhibited an ideal biocorrosion rate within murine aortas, thus raising the possibility of zinc as a candidate base material for endovascular stenting applications. This study was undertaken to further assess the arterial biocompatibility of metallic zinc. Metallic zinc wires were punctured and advanced into the rat abdominal aorta lumen for up to 6.5months. This study demonstrated that metallic zinc did not provoke responses that often contribute to restenosis. Low cell densities and neointimal tissue thickness, along with tissue regeneration within the corroding implant, point to optimal biocompatibility of corroding zinc. Furthermore, the lack of progression in neointimal tissue thickness over 6.5months or the presence of smooth muscle cells near the zinc implant suggest that the products of zinc corrosion may suppress the activities of inflammatory and smooth muscle cells.

  3. Metallic Zinc Exhibits Optimal Biocompatibility for Bioabsorbable Endovascular Stents

    Science.gov (United States)

    Bowen, Patrick K.; Guillory, Roger J.; Shearier, Emily R.; Seitz, Jan-Marten; Drelich, Jaroslaw; Bocks, Martin; Zhao, Feng; Goldman, Jeremy

    2015-01-01

    Although corrosion resistant bare metal stents are considered generally effective, their permanent presence in a diseased artery is an increasingly recognized limitation due to the potential for long-term complications. We previously reported that metallic zinc exhibited an ideal biocorrosion rate within murine aortas, thus raising the possibility of zinc as a candidate base material for endovascular stenting applications. This study was undertaken to further assess the arterial biocompatibility of metallic zinc. Metallic zinc wires were punctured and advanced into the rat abdominal aorta lumen for up to 6.5 months. This study demonstrated that metallic zinc did not provoke responses that often contribute to restenosis. Low cell densities and neointimal tissue thickness, along with tissue regeneration within the corroding implant, point to optimal biocompatibility of corroding zinc. Furthermore, the lack of progression in neointimal tissue thickness over 6.5 months or the presence of smooth muscle cells near the zinc implant suggest that the products of zinc corrosion may suppress the activities of inflammatory and smooth muscle cells. PMID:26249616

  4. Accessing the biocompatibility of layered double hydroxide by intramuscular implantation: histological and microcirculation evaluation

    Science.gov (United States)

    Cunha, Vanessa Roberta Rodrigues; de Souza, Rodrigo Barbosa; da Fonseca Martins, Ana Maria Cristina Rebello Pinto; Koh, Ivan Hong Jun; Constantino, Vera Regina Leopoldo

    2016-01-01

    Biocompatibility of layered double hydroxides (LDHs), also known as hydrotalcite-like materials or double metal hydroxides, was investigated by in vivo assays via intramuscular tablets implantation in rat abdominal wall. The tablets were composed by chloride ions intercalated into LDH of magnesium/aluminum (Mg2Al-Cl) and zinc/aluminum (Zn2Al-Cl). The antigenicity and tissue integration capacity of LDHs were assessed histologically after 7 and 28 days post-implantation. No fibrous capsule nearby the LDH was noticed for both materials as well any sign of inflammatory reactions. Sidestream Dark Field imaging, used to monitor in real time the microcirculation in tissues, revealed overall integrity of the microcirculatory network neighboring the tablets, with no blood flow obstruction, bleeding and/or increasing of leukocyte endothelial adhesion. After 28 days Mg2Al-Cl promoted multiple collagen invaginations (mostly collagen type-I) among its fragments while Zn2Al-Cl induced predominantly collagen type–III. This work supports previous results in the literature about LDHs compatibility with living matter, endorsing them as functional materials for biomedical applications. PMID:27480483

  5. PP13, maternal ABO blood groups and the risk assessment of pregnancy complications.

    Directory of Open Access Journals (Sweden)

    Nandor Gabor Than

    Full Text Available BACKGROUND: Placental Protein 13 (PP13, an early biomarker of preeclampsia, is a placenta-specific galectin that binds beta-galactosides, building-blocks of ABO blood-group antigens, possibly affecting its bioavailability in blood. METHODS AND FINDINGS: We studied PP13-binding to erythrocytes, maternal blood-group effect on serum PP13 and its performance as a predictor of preeclampsia and intrauterine growth restriction (IUGR. Datasets of maternal serum PP13 in Caucasian (n = 1078 and Hispanic (n = 242 women were analyzed according to blood groups. In vivo, in vitro and in silico PP13-binding to ABO blood-group antigens and erythrocytes were studied by PP13-immunostainings of placental tissue-microarrays, flow-cytometry of erythrocyte-bound PP13, and model-building of PP13--blood-group H antigen complex, respectively. Women with blood group AB had the lowest serum PP13 in the first trimester, while those with blood group B had the highest PP13 throughout pregnancy. In accordance, PP13-binding was the strongest to blood-group AB erythrocytes and weakest to blood-group B erythrocytes. PP13-staining of maternal and fetal erythrocytes was revealed, and a plausible molecular model of PP13 complexed with blood-group H antigen was built. Adjustment of PP13 MoMs to maternal ABO blood group improved the prediction accuracy of first trimester maternal serum PP13 MoMs for preeclampsia and IUGR. CONCLUSIONS: ABO blood group can alter PP13-bioavailability in blood, and it may also be a key determinant for other lectins' bioavailability in the circulation. The adjustment of PP13 MoMs to ABO blood group improves the predictive accuracy of this test.

  6. PP13, Maternal ABO Blood Groups and the Risk Assessment of Pregnancy Complications

    Science.gov (United States)

    Than, Nandor Gabor; Romero, Roberto; Meiri, Hamutal; Erez, Offer; Xu, Yi; Tarquini, Federica; Barna, Laszlo; Szilagyi, Andras; Ackerman, Ron; Sammar, Marei; Fule, Tibor; Karaszi, Katalin; Kovalszky, Ilona; Dong, Zhong; Kim, Chong Jai; Zavodszky, Peter; Papp, Zoltan; Gonen, Ron

    2011-01-01

    Background Placental Protein 13 (PP13), an early biomarker of preeclampsia, is a placenta-specific galectin that binds beta-galactosides, building-blocks of ABO blood-group antigens, possibly affecting its bioavailability in blood. Methods and Findings We studied PP13-binding to erythrocytes, maternal blood-group effect on serum PP13 and its performance as a predictor of preeclampsia and intrauterine growth restriction (IUGR). Datasets of maternal serum PP13 in Caucasian (n = 1078) and Hispanic (n = 242) women were analyzed according to blood groups. In vivo, in vitro and in silico PP13-binding to ABO blood-group antigens and erythrocytes were studied by PP13-immunostainings of placental tissue-microarrays, flow-cytometry of erythrocyte-bound PP13, and model-building of PP13 - blood-group H antigen complex, respectively. Women with blood group AB had the lowest serum PP13 in the first trimester, while those with blood group B had the highest PP13 throughout pregnancy. In accordance, PP13-binding was the strongest to blood-group AB erythrocytes and weakest to blood-group B erythrocytes. PP13-staining of maternal and fetal erythrocytes was revealed, and a plausible molecular model of PP13 complexed with blood-group H antigen was built. Adjustment of PP13 MoMs to maternal ABO blood group improved the prediction accuracy of first trimester maternal serum PP13 MoMs for preeclampsia and IUGR. Conclusions ABO blood group can alter PP13-bioavailability in blood, and it may also be a key determinant for other lectins' bioavailability in the circulation. The adjustment of PP13 MoMs to ABO blood group improves the predictive accuracy of this test. PMID:21799738

  7. A comparison of blood gases, biochemistry, and hematology to ecomorphology in a health assessment of pinfish (Lagodon rhomboides

    Directory of Open Access Journals (Sweden)

    Sara Collins

    2016-08-01

    Full Text Available Despite the promise of hematological parameters and blood chemistry in monitoring the health of marine fishes, baseline data is often lacking for small fishes that comprise central roles in marine food webs. This study establishes blood chemistry and hematological baseline parameters for the pinfish Lagodon rhomboides, a small marine teleost that is among the most dominant members of near-shore estuarine communities of the Atlantic Ocean and Gulf of Mexico. Given their prominence, pinfishes are an ideal candidate species to use as a model for monitoring changes across a wide range of near-shore marine communities. However, pinfishes exhibit substantial morphological differences associated with a preference for feeding in primarily sea-grass or sand dominated habitats, suggesting that differences in the foraging ecology of individuals could confound health assessments. Here we collect baseline data on the blood physiology of pinfish while assessing the relationship between blood parameters and measured aspects of feeding morphology using data collected from 37 individual fish. Our findings provide new baseline health data for this important near shore fish species and find no evidence for a strong linkage between blood physiology and either sex or measured aspects of feeding morphology. Comparing our hematological and biochemical data to published results from other marine teleost species suggests that analyses of trends in blood value variation correlated with major evolutionary transitions in ecology will shed new light on the physiological changes that underlie the successful diversification of fishes.

  8. A comparison of blood gases, biochemistry, and hematology to ecomorphology in a health assessment of pinfish (Lagodon rhomboides).

    Science.gov (United States)

    Collins, Sara; Dornburg, Alex; Flores, Joseph M; Dombrowski, Daniel S; Lewbart, Gregory A

    2016-01-01

    Despite the promise of hematological parameters and blood chemistry in monitoring the health of marine fishes, baseline data is often lacking for small fishes that comprise central roles in marine food webs. This study establishes blood chemistry and hematological baseline parameters for the pinfish Lagodon rhomboides, a small marine teleost that is among the most dominant members of near-shore estuarine communities of the Atlantic Ocean and Gulf of Mexico. Given their prominence, pinfishes are an ideal candidate species to use as a model for monitoring changes across a wide range of near-shore marine communities. However, pinfishes exhibit substantial morphological differences associated with a preference for feeding in primarily sea-grass or sand dominated habitats, suggesting that differences in the foraging ecology of individuals could confound health assessments. Here we collect baseline data on the blood physiology of pinfish while assessing the relationship between blood parameters and measured aspects of feeding morphology using data collected from 37 individual fish. Our findings provide new baseline health data for this important near shore fish species and find no evidence for a strong linkage between blood physiology and either sex or measured aspects of feeding morphology. Comparing our hematological and biochemical data to published results from other marine teleost species suggests that analyses of trends in blood value variation correlated with major evolutionary transitions in ecology will shed new light on the physiological changes that underlie the successful diversification of fishes.

  9. Assessing Acceptability of Short Message Service Based Interventions towards Becoming Future Voluntary Blood Donors

    Directory of Open Access Journals (Sweden)

    Sana Saleem

    2014-01-01

    Full Text Available All blood bank services, especially those of developing countries, face a major shortfall of blood donations due to lack of voluntary blood donors. Our study aims to evaluate the acceptability of Short Message Service based interventions towards becoming voluntary blood donors among medical university students of Karachi, Pakistan. Methods. A total of 350 medical students were approached in medical universities of Karachi, Pakistan, using a nonprobability convenient sampling technique. Data collectors administered a self-made questionnaire to each participant using an interview based format. All data was recorded and analyzed on SPSS 16. Results. 350 participants, having a mean age of 21.47 ± 1.36, were included in our study with 30.6% (107/350 being males and 69.4% (243/350 being females. 93.4% (327/350 of participants agreed that donating blood was healthy, but only 26% had donated blood in the past with 79.1% donating voluntarily. 65.7% (230/350 of the participants agreed to take part in Short Message Service based behavioral interventions to become voluntary blood donors with 69.7% (244/350 also agreeing that Short Message Service reminders will promote them to donate blood more often. Conclusion. With university students willing to become voluntary blood donors, Pakistani blood banks can carry out Short Message Service based interventions to encourage them to donate blood.

  10. Assessing Acceptability of Short Message Service Based Interventions towards Becoming Future Voluntary Blood Donors.

    Science.gov (United States)

    Saleem, Sana; Wasim, Anum; Sabih, Sidra; Khan, Ayisha Farooq; Rizvi, Madiha Hasan; Jillani, Umaima Ayesha; Syed, Mujtaba Jamal; Mumtaz, Madiha; Mumtaz, Yasmeen; Shehzad, Abdul Moid; Dawani, Om; Khan, Saima; Munir, Sheheryar; Asad, Nava; Kazi, Abdul Nafey

    2014-01-01

    All blood bank services, especially those of developing countries, face a major shortfall of blood donations due to lack of voluntary blood donors. Our study aims to evaluate the acceptability of Short Message Service based interventions towards becoming voluntary blood donors among medical university students of Karachi, Pakistan. Methods. A total of 350 medical students were approached in medical universities of Karachi, Pakistan, using a nonprobability convenient sampling technique. Data collectors administered a self-made questionnaire to each participant using an interview based format. All data was recorded and analyzed on SPSS 16. Results. 350 participants, having a mean age of 21.47 ± 1.36, were included in our study with 30.6% (107/350) being males and 69.4% (243/350) being females. 93.4% (327/350) of participants agreed that donating blood was healthy, but only 26% had donated blood in the past with 79.1% donating voluntarily. 65.7% (230/350) of the participants agreed to take part in Short Message Service based behavioral interventions to become voluntary blood donors with 69.7% (244/350) also agreeing that Short Message Service reminders will promote them to donate blood more often. Conclusion. With university students willing to become voluntary blood donors, Pakistani blood banks can carry out Short Message Service based interventions to encourage them to donate blood.

  11. An Assessment of Whole Blood and Fractions by Nested PCR as a DNA Source for Diagnosing Canine Ehrlichiosis and Anaplasmosis

    Directory of Open Access Journals (Sweden)

    Tereza Emmanuelle de Farias Rotondano

    2012-01-01

    Full Text Available Ehrlichiosis and anaplasmosis are tick-borne diseases. Ehrlichia canis and Anaplasma platys infect mainly white cells and platelets, respectively. The main DNA source for PCR is peripheral blood, but the potential of blood cell fractions has not been extensively investigated. This study aims at assessment of whole blood (WB and blood fractions potential in nested PCR (nPCR to diagnose canine ehrlichiosis and anaplasmosis. The 16S rRNA gene was amplified in 71.4, 17.8, 31.57, and 30% of the WB, granulocyte (G, mononuclear cells (M, and buffy coat (BC samples. Compared to the WB, the sensitivity of the PCR was 42.86% for the M, and BC fractions, 21.43% for the G, and 33.33% for the blood clot (C. There was fair agreement between the WB and M, BC and C, and slight with the G. Fair agreement occurred between the nPCR and morulae in the blood smear. One animal was coinfected with A. platys and E. canis. This study provided the first evidence of A. platys infection in dogs in Paraíba, Brazil, and demonstrated that WB is a better DNA source than blood fractions to detect Ehrlichia and Anaplasma by nPCR, probably because of the plasma bacterial concentration following host cell lysis.

  12. Invasively Measured Aortic Systolic Blood Pressure and Office Systolic Blood Pressure in Cardiovascular Risk Assessment: A Prospective Cohort Study

    DEFF Research Database (Denmark)

    Laugesen, Esben; Knudsen, Søren T; Hansen, Klavs W

    2016-01-01

    myocardial infarction, stroke, and death. Discrimination and reclassification were assessed using Harrell's C and the Continuous Net Reclassification Index. Data were analyzed with and without stratification by diabetes mellitus status. During a median follow-up period of 3.7 years (range: 0.1-10.8 years......), 422 strokes, 511 myocardial infarctions, and 1530 deaths occurred. Both office and aortic systolic BP were associated with stroke in patients with diabetes mellitus (hazard ratio per 10 mm Hg, 1.18 [95% confidence interval, 1.07-1.30] and 1.14 [95% confidence interval, 1.05-1.24], respectively...

  13. Decreased microvascular cerebral blood flow assessed by diffuse correlation spectroscopy after repetitive concussions in mice.

    Science.gov (United States)

    Buckley, Erin M; Miller, Benjamin F; Golinski, Julianne M; Sadeghian, Homa; McAllister, Lauren M; Vangel, Mark; Ayata, Cenk; Meehan, William P; Franceschini, Maria Angela; Whalen, Michael J

    2015-12-01

    Repetitive concussions are associated with long-term cognitive dysfunction that can be attenuated by increasing the time intervals between concussions; however, biomarkers of the safest rest interval between injuries remain undefined. We hypothesize that deranged cerebral blood flow (CBF) is a candidate biomarker for vulnerability to repetitive concussions. Using a mouse model of human concussion, we examined the effect of single and repetitive concussions on cognition and on an index of CBF (CBFi) measured with diffuse correlation spectroscopy. After a single mild concussion, CBFi was reduced by 35±4% at 4 hours (Pconcussions spaced 1 day apart, CBFi was also reduced from preinjury levels 4 hours after each concussion but had returned to preinjury levels by 72 hours after the final concussion. Interestingly, in this repetitive concussion model, lower CBFi values measured both preinjury and 4 hours after the third concussion were associated with worse performance on the Morris water maze assessed 72 hours after the final concussion. We conclude that low CBFi measured either before or early on in the evolution of injury caused by repetitive concussions could be a useful predictor of cognitive outcome.

  14. Diabetes Technology: Markers, Monitoring, Assessment, and Control of Blood Glucose Fluctuations in Diabetes

    Directory of Open Access Journals (Sweden)

    Boris P. Kovatchev

    2012-01-01

    Full Text Available People with diabetes face a life-long optimization problem: to maintain strict glycemic control without increasing their risk for hypoglycemia. Since the discovery of insulin in 1921, the external regulation of diabetes by engineering means has became a hallmark of this optimization. Diabetes technology has progressed remarkably over the past 50 years—a progress that includes the development of markers for diabetes control, sophisticated monitoring techniques, mathematical models, assessment procedures, and control algorithms. Continuous glucose monitoring (CGM was introduced in 1999 and has evolved from means for retroactive review of blood glucose profiles to versatile reliable devices, which monitor the course of glucose fluctuations in real time and provide interactive feedback to the patient. Technology integrating CGM with insulin pumps is now available, opening the field for automated closed-loop control, known as the artificial pancreas. Following a number of in-clinic trials, the quest for a wearable ambulatory artificial pancreas is under way, with a first prototype tested in outpatient setting during the past year. This paper discusses key milestones of diabetes technology development, focusing on the progress in the past 10 years and on the artificial pancreas—still not a cure, but arguably the most promising treatment of diabetes to date.

  15. Malabsorption Blood Test: Assessing Fat Absorption in Patients with Cystic Fibrosis and Pancreatic Insufficiency

    Science.gov (United States)

    Mascarenhas, Maria R.; Mondick, John; Barrett, Jeffrey S.; Wilson, Martha; Stallings, Virginia A.; Schall, Joan I.

    2015-01-01

    The Malabsorption Blood Test (MBT), consisting of pentadecanoic acid (PA), a free fatty acid and triheptadecanoic acid (THA), a triglyceride that requires pancreatic lipase for absorption of the heptadecanoic acid (HA), was developed to assess fat malabsorption in patients with cystic fibrosis (CF) and pancreatic insufficiency (PI). The objective was to construct a population pharmacokinetic (PK) model to describe PA and HA disposition in healthy subjects and CF subjects. A model was simultaneously fit to PA and HA concentrations, consisting of one compartment disposition and a transit model to describe absorption. PA bioavailability estimates for CF subjects without pancreatic enzyme administration [1.07 (0.827,1.42)] and with enzymes [0.88 (0.72,1.09)] indicated PA absorption comparable to healthy subjects. HA bioavailability in CF without enzyme administration was 0.0292 (0.0192,0.0459), and with enzymes increased to 0.606 (0.482,0.823). In CF, compared to taking enzymes with the MBT, HA bioavailability was further decreased by factors of 0.829 (0.664,0.979) and 0.78 (0.491,1.13) with enzymes taken 30 and 60 minutes after MBT, respectively. The MBT detected differences in fat absorption in subjects with CF with and without enzyme administration and with changes in enzyme timing. Future studies will address application of the MBT in CF and other malabsorption diagnoses. PMID:25689042

  16. Assessment of regional pulmonary blood flow using (68)Ga-DOTA PET.

    Science.gov (United States)

    Velasco, Carlos; Mateo, Jesus; Santos, Arnoldo; Mota-Cobian, Adriana; Herranz, Fernando; Pellico, Juan; Mota, Ruben A; España, Samuel; Ruiz-Cabello, Jesus

    2017-12-01

    In vivo determination of regional pulmonary blood flow (PBF) is a valuable tool for the evaluation of many lung diseases. In this study, the use of (68)Ga-DOTA PET for the in vivo quantitative determination of regional PBF is proposed. This methodology was implemented and tested in healthy pigs and validated using fluorescent microspheres. The study was performed on young large white pigs (n = 4). To assess the reproducibility and consistency of the method, three PET scans were obtained for each animal. Each radiotracer injection was performed simultaneously to the injection of fluorescent microspheres. PBF images were generated applying a two-compartment exchange model over the dynamic PET images. PET and microspheres values were compared by regression analysis and Bland-Altman plot. The capability of the proposed technique to produce 3D regional PBF images was demonstrated. The correlation evaluation between (68)Ga-DOTA PET and microspheres showed a good and significant correlation (r = 0.74, P PET imaging with the use of (68)Ga/(68)Ge generators. Thus, (68)Ga-DOTA PET emerges as a potential inexpensive method for measuring PBF in clinical settings with an extended use.

  17. Assessment of local changes of cerebral perfusion and blood concentration by ultrasound harmonic B-mode contrast measurement in piglet.

    NARCIS (Netherlands)

    Wijk, M.C. van; Klaessens, J.H.G.M.; Hopman, J.C.W.; Liem, K.D.; Thijssen, J.M.

    2003-01-01

    This study tested the hypothesis that changes in the blood concentration, and possibly in the perfusion, of different areas in the brain can be assessed by the use of ultrasound contrast agent (CA) and (linear) echo densitometry. The experiments were performed with piglets (n=3) under general anesth

  18. Biocompatibility of hydrophilic silica-coated CdTe quantum dots and magnetic nanoparticles

    Science.gov (United States)

    Ruan, Jing; Wang, Kan; Song, Hua; Xu, Xin; Ji, Jiajia; Cui, Daxiang

    2011-12-01

    Fluorescent magnetic nanoparticles exhibit great application prospects in biomedical engineering. Herein, we reported the effects of hydrophilic silica-coated CdTe quantum dots and magnetic nanoparticles (FMNPs) on human embryonic kidney 293 (HEK293) cells and mice with the aim of investigating their biocompatibility. FMNPs with 150 nm in diameter were prepared, and characterized by high-resolution transmission electron microscopy and photoluminescence (PL) spectra and magnetometer. HEK293 cells were cultured with different doses of FMNPs (20, 50, and 100μ g/ml) for 1-4 days. Cell viability and adhesion ability were analyzed by CCK8 method and Western blotting. 30 mice were randomly divided into three groups, and were, respectively, injected via tail vein with 20, 60, and 100 μg FMNPs, and then were, respectively, raised for 1, 7, and 30 days, then their lifespan, important organs, and blood biochemical parameters were analyzed. Results show that the prepared water-soluble FMNPs had high fluorescent and magnetic properties, less than 50 μg/ml of FMNPs exhibited good biocompatibility to HEK293 cells, the cell viability, and adhesion ability were similar to the control HEK293 cells. FMNPs primarily accumulated in those organs such as lung, liver, and spleen. Lung exposed to FMNPs displayed a dose-dependent inflammatory response, blood biochemical parameters such as white blood cell count (WBC), alanine aminotransferase (ALT), and aspartate aminotransferase (AST), displayed significant increase when the FMNPs were injected into mice at dose of 100μg. In conclusion, FMNPs exhibit good biocompatibility to cells under the dose of less than 50 μg/ml, and to mice under the dose of less than 2mg/kg body weight. The FMNPs' biocompatibility must be considered when FMNPs are used for in vivo diagnosis and therapy.

  19. Assessment of Blood Contamination in Biological Fluids Using MALDI-TOF MS.

    Science.gov (United States)

    Laks, Katrina; Kirsipuu, Tiina; Dmitrijeva, Tuuli; Salumets, Andres; Palumaa, Peep

    2016-06-01

    Biological fluid sample collection often includes the risk of blood contamination that may alter the proteomic profile of biological fluid. In proteomics studies, exclusion of contaminated samples is usually based on visual inspection and counting of red blood cells in the sample; analysis of specific blood derived proteins is less used. To fill the gap, we developed a fast and sensitive method for ascertainment of blood contamination in crude biological fluids, based on specific blood-derived protein, hemoglobin detection by MALDI-TOF MS. The MALDI-TOF MS based method allows detection of trace hemoglobin with the detection limit of 0.12 nM. UV-spectrometry, which was used as reference method, was found to be less sensitive. The main advantages of the presented method are that it is fast, effective, sensitive, requires very small sample amount and can be applied for detection of blood contamination in various biological fluids collected for proteomics studies. Method applicability was tested on human cerebrospinal and follicular fluid, which proteomes generally do not contain hemoglobin, however, which possess high risk for blood contamination. Present method successfully detected the blood contamination in 12 % of cerebrospinal fluid and 24 % of follicular fluid samples. High percentage of contaminated samples accentuates the need for initial inspection of proteomic samples to avoid incorrect results from blood proteome overlap.

  20. Assessing anxiety levels and empathic tendency in blood and platelet donors.

    Science.gov (United States)

    Kılıç, Suar Çakı; Doğan, Erdoğan; Sevimligül, Gülgün; Yücel, Birsen; Bolat, Fatih; Kavakçı, Onder; Sencan, Mehmet

    2013-06-01

    In spite of a constantly-increasing requirement for blood transfusion in the world, blood donation does not exhibit an increase at the same rate. In Turkey with a population of 74 million, only 15 per 10,000 people donate blood regularly and rate of voluntary blood donation is very low compared to developed countries. The aim of this study is to determine empathic level of donors and anxiety levels of blood and platelet donors and also to enable comfort and motivation of donors by taking precautions for reducing their anxieties. This prospective and descriptive study was conducted with 100 voluntary donors (50 blood donors, 50 platelet donors) who admitted to Blood Centre of Cumhuriyet University Hospital between 15 March 2012 and 30 April 2012. Average age of these donors was 27 (19-48)years. The mean scores of donors from Empathic Tendency Scale (ETS), State Anxiety Invertory (SAI) and Trait Anxiety Inventory (TAI) were 70 (49-83), 40 (33-45) and 34 (30-44), respectively. ETS score of those donating blood/platelet for the first time was low, >1 is higher in those who donated previously. SAI and TAI scores of blood donors were higher than those of platelet donors (pempathy. Donation made during the continuous disclosure is an important factor for being a donor.

  1. Biocompatibility of MIM 316L stainless steel

    Institute of Scientific and Technical Information of China (English)

    ZHU Shai-hong; WANG Guo-hui; ZHAO Yan-zhong; LI Yi-ming; ZHOU Ke-chao; HUANG Bai-yun

    2005-01-01

    To evaluate the bioeompatibility of MIM 316L stainless steel, the percentage of S-period cells were detected by flow cytometry after L929 incubated with extraction of MIM 316L stainless steel, using titanium implant materials of clinical application as the contrast. Both materials were implanted in animal and the histopathological evaluations were carried out. The statistical analyses show that there are no significant differences between two groups (P>0.05), which demonstrates that MIM 316L stainless steel has a good biocompatibility.

  2. Assessment of turbulent viscous stress using ICOSA 4D Flow MRI for prediction of hemodynamic blood damage

    Science.gov (United States)

    Ha, Hojin; Lantz, Jonas; Haraldsson, Henrik; Casas, Belen; Ziegler, Magnus; Karlsson, Matts; Saloner, David; Dyverfeldt, Petter; Ebbers, Tino

    2016-12-01

    Flow-induced blood damage plays an important role in determining the hemodynamic impact of abnormal blood flow, but quantifying of these effects, which are dominated by shear stresses in highly fluctuating turbulent flow, has not been feasible. This study evaluated the novel application of turbulence tensor measurements using simulated 4D Flow MRI data with six-directional velocity encoding for assessing hemodynamic stresses and corresponding blood damage index (BDI) in stenotic turbulent blood flow. The results showed that 4D Flow MRI underestimates the maximum principal shear stress of laminar viscous stress (PLVS), and overestimates the maximum principal shear stress of Reynolds stress (PRSS) with increasing voxel size. PLVS and PRSS were also overestimated by about 1.2 and 4.6 times at medium signal to noise ratio (SNR) = 20. In contrast, the square sum of the turbulent viscous shear stress (TVSS), which is used for blood damage index (BDI) estimation, was not severely affected by SNR and voxel size. The square sum of TVSS and the BDI at SNR >20 were underestimated by less than 1% and 10%, respectively. In conclusion, this study demonstrated the feasibility of 4D Flow MRI based quantification of TVSS and BDI which are closely linked to blood damage.

  3. Biocompatible yogurt carbon dots: evaluation of utilization for medical applications

    Science.gov (United States)

    Dinç, Saliha; Kara, Meryem; Demirel Kars, Meltem; Aykül, Fatmanur; Çiçekci, Hacer; Akkuş, Mehmet

    2017-09-01

    In this study, carbon dots (CDs) were produced from yogurt, a fermented milk product, via microwave-assisted process (800 W) in 30 min without using any additional chemical agents. Yogurt CDs had outstanding nitrogen and oxygen ratios. These dots were monodisperse and about 2 nm sized. The toxicological assessments of yogurt carbon dots in human cancer cells and normal epithelial cells and their fluorescence imaging in living cell system were carried out. Yogurt carbon dots had intense fluorescent signal under confocal microscopy and good fluorescence stability in living cell system. The resulting yogurt carbon dots exhibited high biocompatibility up to 7.1 mg/mL CD concentration which may find utilization in medical applications such as cellular tracking, imaging and drug delivery. Yogurt carbon dots have potential to be good diagnostic agents to visualize cancer cells which may be developed as a therapeutic carrier.

  4. Synthesis of biocompatible multicolor luminescent carbon dots for bioimaging applications

    Directory of Open Access Journals (Sweden)

    Nagaprasad Puvvada, B N Prashanth Kumar, Suraj Konar, Himani Kalita, Mahitosh Mandal and Amita Pathak

    2012-01-01

    Full Text Available Water-soluble carbon dots (C-dots were prepared through microwave-assisted pyrolysis of an aqueous solution of dextrin in the presence of sulfuric acid. The C-dots produced showed multicolor luminescence in the entire visible range, without adding any surface-passivating agent. X-ray diffraction and Fourier transform infrared spectroscopy studies revealed the graphitic nature of the carbon and the presence of hydrophilic groups on the surface, respectively. The formation of uniformly distributed C-dots and their luminescent properties were, respectively, revealed from transmission electron microscopy and confocal laser scanning microscopy. The biocompatible nature of C-dots was confirmed by a cytotoxicity assay on MDA-MB-468 cells and their cellular uptake was assessed through a localization study.

  5. An Assessment of a Rapid Microwave Thawing Procedure for Frozen Red Blood Cells.

    Science.gov (United States)

    1992-08-01

    Restall CJ, Leonard PF, Taswell HF, Holaday RE. A microwave blood warmer: preliminary report. Anesthesia and Analgesia 4,5(5):625-628, 1967. 9. duPlessis...Leonard PF, Restall CJ, Taswell HF, Fairbanks VF. Microwave warming of bank blood. Anesthesia and Analgesia 50(2):302-305, 1971’ 12. Stapies PJ

  6. Umbilical cord blood lactate: a valuable tool in the assessment of fetal metabolic acidosis

    DEFF Research Database (Denmark)

    Gjerris, Anne Cathrine Roslev; Staer-Jensen, Jette; Jørgensen, Jan Stener

    2008-01-01

    The aim of the present study was (1) to evaluate the relationship between umbilical cord arterial blood lactate and pH, standard base excess (SBE), and actual base excess (ABE) at delivery and (2) to suggest a cut-off level of umbilical cord arterial blood lactate in predicting fetal asphyxia using...

  7. Evaluation of changes of intracranial blood flow after carotid artery stenting using digital subtraction angiography flow assessment

    Institute of Scientific and Technical Information of China (English)

    Hajime; Wada; Masato; Saito; Kyousuke; Kamada

    2015-01-01

    AIM: To evaluate the changes of intracranial blood flow after carotid artery stenting(CAS), using the flow assessment application "Flow-Insight", which was developed in our department.METHODS: Twenty patients treated by CAS participated in this study. We analyzed the change in concentration of the contrast media at the anterior-posterior and profile view image with the flow assessment application "Flow-Insight". And we compared the results with N-isopropyl-p-[123I] iodoamphetamine-single-photon emission computed tomography(IMP SPECT) performed before and after the treatment. RESULTS: From this study, 200% of the parameter "blood flow" change in the post/pre-treatment is suggested as the critical line of the hyperperfusion syndrome arise. Although the observed blood flow increase in the digital subtraction angiography system did not strongly correlate with the rate of increase of SPECT, the "Flow-Insight" reflected the rate of change of the vessels well. However, for patients with reduced reserve blood flow before CAS, a highly elevated site was in agreement with the site analysis results. CONCLUSION: We concluded that the cerebral angiography flow assessment application was able to more finely reveal hyperperfusion regions in the brain after CAS compared to SPECT.

  8. Compact Laser Doppler Flowmeter (LDF Fundus Camera for the Assessment of Retinal Blood Perfusion in Small Animals.

    Directory of Open Access Journals (Sweden)

    Marielle Mentek

    Full Text Available Noninvasive techniques for ocular blood perfusion assessment are of crucial importance for exploring microvascular alterations related to systemic and ocular diseases. However, few techniques adapted to rodents are available and most are invasive or not specifically focused on the optic nerve head (ONH, choroid or retinal circulation. Here we present the results obtained with a new rodent-adapted compact fundus camera based on laser Doppler flowmetry (LDF.A confocal miniature flowmeter was fixed to a specially designed 3D rotating mechanical arm and adjusted on a rodent stereotaxic table in order to accurately point the laser beam at the retinal region of interest. The linearity of the LDF measurements was assessed using a rotating Teflon wheel and a flow of microspheres in a glass capillary. In vivo reproducibility was assessed in Wistar rats with repeated measurements (inter-session and inter-day of retinal arteries and ONH blood velocity in six and ten rats, respectively. These parameters were also recorded during an acute intraocular pressure increase to 150 mmHg and after heart arrest (n = 5 rats.The perfusion measurements showed perfect linearity between LDF velocity and Teflon wheel or microsphere speed. Intraclass correlation coefficients for retinal arteries and ONH velocity (0.82 and 0.86, respectively indicated strong inter-session repeatability and stability. Inter-day reproducibility was good (0.79 and 0.7, respectively. Upon ocular blood flow cessation, the retinal artery velocity signal substantially decreased, whereas the ONH signal did not significantly vary, suggesting that it could mostly be attributed to tissue light scattering.We have demonstrated that, while not adapted for ONH blood perfusion assessment, this device allows pertinent, stable and repeatable measurements of retinal blood perfusion in rats.

  9. Umbilical cord blood androgen levels in girls and boys assessed by gas chromatography-tandem mass spectrometry.

    Science.gov (United States)

    Lundell, Anna-Carin; Ryberg, Henrik; Vandenput, Liesbeth; Rudin, Anna; Ohlsson, Claes; Tivesten, Åsa

    2017-07-01

    Androgen exposure of the fetus during gestation plays an important role in human physiology and pathophysiology, but assessment of androgens, in particular dihydrotestosterone (DHT), in human umbilical cord blood is technically challenging. The aim of this study was to assess umbilical cord androgen levels, including DHT, at birth by a highly sensitive assay, and study their association with sex of the infant, sex-hormone-binding globulin (SHBG) levels, and gestational age at delivery. Swedish infants (27 girls, 26 boys) were recruited at maternity care clinics in Southern Sweden. Umbilical cord blood levels of dehydroepiandrosterone (DHEA), androstenedione, testosterone and DHT at delivery were assessed by a gas chromatography-tandem mass spectrometry assay. Cord blood levels of DHT were 2.4-fold higher in boys (median 27.8pg/mL) than in girls (11.5pg/mL), while the sex difference was less pronounced for testosterone (1.3-fold higher in boys) and non-significant for DHEA and androstenedione. Gestational age at delivery associated inversely with DHT levels in boys and with DHEA levels in girls. There was a strong inverse correlation between SHBG and DHEA in both sexes, while there were no associations between SHBG and testosterone or DHT levels. In conclusion, using state of the art technology, we report that there is a pronounced sexual dimorphism in human umbilical cord blood DHT levels. The possibility to assess a complete androgen profile in human cord blood opens up for future increased understanding of the biological impact of the fetal androgen milieu. Copyright © 2017 Elsevier Ltd. All rights reserved.

  10. Biocompatibility and Effectiveness Evaluation of a New Hemostatic Embolization Agent: Thrombin Loaded Alginate Calcium Microsphere

    Directory of Open Access Journals (Sweden)

    Fengqi Xuan

    2017-01-01

    Full Text Available Background. Until now, there has been no ideal embolization agent for hemorrhage in interventional treatment. In this study, the thrombin was encapsulated in alginate calcium microsphere using electrostatic droplet technique to produce new embolization agent: thrombin loaded alginate calcium microspheres (TACMs. Objectives. The present work was to evaluate the biocompatibility and hemostatic efficiency of TACMs. Methods. Cell cytotoxicity, hemolysis, and superselective embolization of dog liver arteries were performed to investigate the biocompatibility of TACMs. To clarify the embolic effect of TACMs mixed thrombus in vivo, hepatic artery injury animal model of 6 beagles was established and transcatheter artery embolization for bleeding was performed. Results. Coculture with VECs revealed the noncytotoxicity of TACMs, and the hemolysis experiment was negligible. Moreover, the histological study of TACMs in liver blood vessel showed signs of a slight inflammatory reaction. The results of transcatheter application of TACMs mixed thrombus for bleeding showed that the blood flow was shut down completely after the TACMs mixed thrombus was delivered and the postprocedural survival rate of animal models at 12 weeks was 100%. Conclusions. With their good biocompatibility and superior hemostatic efficiency, TACMs might be a promising new hemostatic agent with a wide range of potential applications.

  11. Biocompatibility and Effectiveness Evaluation of a New Hemostatic Embolization Agent: Thrombin Loaded Alginate Calcium Microsphere

    Science.gov (United States)

    Xuan, Fengqi; Rong, Jingjing; Liang, Ming; Zhang, Xuwen; Sun, Jingyang; Zhao, Lijun; Li, Yang; Liu, Dan; Li, Fei; Wang, Xiaozeng

    2017-01-01

    Background. Until now, there has been no ideal embolization agent for hemorrhage in interventional treatment. In this study, the thrombin was encapsulated in alginate calcium microsphere using electrostatic droplet technique to produce new embolization agent: thrombin loaded alginate calcium microspheres (TACMs). Objectives. The present work was to evaluate the biocompatibility and hemostatic efficiency of TACMs. Methods. Cell cytotoxicity, hemolysis, and superselective embolization of dog liver arteries were performed to investigate the biocompatibility of TACMs. To clarify the embolic effect of TACMs mixed thrombus in vivo, hepatic artery injury animal model of 6 beagles was established and transcatheter artery embolization for bleeding was performed. Results. Coculture with VECs revealed the noncytotoxicity of TACMs, and the hemolysis experiment was negligible. Moreover, the histological study of TACMs in liver blood vessel showed signs of a slight inflammatory reaction. The results of transcatheter application of TACMs mixed thrombus for bleeding showed that the blood flow was shut down completely after the TACMs mixed thrombus was delivered and the postprocedural survival rate of animal models at 12 weeks was 100%. Conclusions. With their good biocompatibility and superior hemostatic efficiency, TACMs might be a promising new hemostatic agent with a wide range of potential applications. PMID:28303245

  12. Validation of the Use of Dried Blood Spot (DBS Method to Assess Vitamin A Status

    Directory of Open Access Journals (Sweden)

    Elham Fallah

    2012-12-01

    Full Text Available Background: Vitamin A deficiency is an important dietary deficiency in the world. Thus, the ne-cessity of screening for deficient populations is obvious. This paper introduces a fast, cheap and relatively reliable method called “dried blood spot” (DBS method in screening the deficient populations. The validity of this method for retinol measurement was investigated.Method: The “precision” and “agreement” criteria of the DBS method were assessed. The preci-sion was calculated and compared with those of plasma using F-test. The agreement was eva-luated using Bland-Altman plot.Results: The imprecision of retinol measurements in dried spots was not significantly different from those of the control (plasma. A good correlation coefficient (r2=0.78 was obtained for dried spots’ retinol measurements versus plasma’s retinol analysis (P < 0.01. Paired t-test showed no significant difference between the DBS and retinol methods on a group level. Imprecision of DBS measurement was acceptable, compared to that of the plasma method. The difference be-tween these two methods was not statistically significant on a group level.Conclusion: Application of DBS standard samples, in which a part of the plasma was replaced with the artificial plasma, was shown to be a reliable calibration mean for retinol measurements in DBS samples. Retinol in dried spots was stable for 90 days. Overall, the DBS method provided a precise measurement of retinol, showing results that were comparable with the measurement of retinol in plasma.

  13. Perfluoroalkyl and polyfluoroalkyl substances in cord blood of newborns in Shanghai, China: Implications for risk assessment.

    Science.gov (United States)

    Wang, Bin; Chen, Qian; Shen, Lixiao; Zhao, Shasha; Pang, Weiyi; Zhang, Jun

    2016-12-01

    Perfluoroalkyl and polyfluoroalkyl substances (PFASs) are commonly used in industrial applications and consumer products, and their potential health impacts are of concern, especially for vulnerable population like fetuses. However, in utero exposure to PFASs and health implications are far from fully characterized in China. To fill in the gap, we analyzed 10 PFASs in cord plasma samples (N=687) collected in Shanghai between 2011 and 2012, one of the regions widely polluted with PFASs in China. A questionnaire survey on maternal and diet-related factors was conducted. Except for perfluoroheptanoic acid (PFHpA) and perfluorooctane sulfonamide (PFOSA), all other PFASs were detected in ˃90% of the samples. Perfluorooctanoic acid (PFOA) was the most predominant PFAS (median value: 6.96ng/mL), followed by perfluorooctane sulfonate (PFOS) (2.48ng/mL). PFOA and PFOS combined contributed to 80% of the total PFASs. The final multiple regression models showed that maternal factors including maternal age, body mass index, gestational age, economic status and educational level as well as consumption of fish and wheat were significantly related with concentrations of PFASs in cord blood. The risk assessment using the hazard quotients (HQs) approach on the basis of plasma PFAS levels indicated no potential concern for developmental toxicity in the local newborns. The results demonstrate the unique profiles of local prenatal exposure to PFASs, suggesting that PFOA has been the primary human exposure due to its widespread use and pollution. Special attention to high PFOA exposure and confirmation of potential determinants should be taken as a priority in the future plan for risk management and actions in this area.

  14. Significance of assess the iron reserves of severe renal anemia patients before and after blood transfusion

    Institute of Scientific and Technical Information of China (English)

    Gui-Fen Zhang

    2015-01-01

    Objective:To study the significance of evaluating hemoglobin and iron reserves in the severe renal anemia patient before and after blood transfusion, to guide clinical treatment.Methods:Simple randomly selected 120 patients in phase 5 of chronic renal failure from the department of nephrology, who are regular dialysis with severe renal anemia, according to the situation of iron reserves before blood transfusion, patients will be divided into its reserves of iron deficiency and iron overload group and normal group, and the three groups were divided into 1 U and 2 U group. Comparing the change of different unit quantity of hemoglobin, serum iron, iron, protein and total iron binding force before and after blood transfusion and variation is compared between groups.Results: Three groups of patients with 1U blood transfusion ,Hemoglobin, serum iron and ferritin, total iron binding force, transferrin saturation are higher before a blood transfusion,The differences were statistically significant; before and after blood transfusion hemoglobin, serum iron and ferritin, total iron binding force, transferrin saturation change in 1 U group normal iron reserves compared with Insufficient iron reserves 1 U group has no statistically significant difference, iron overload 1 U group before and after blood transfusion hemoglobin, serum iron and ferritin, total iron binding force, transferrin saturation change significantly greater than Insufficient iron reserves 1 U group and 1U with normal iron reserves group, the differences were statistically significant; Three groups of patients blood transfusion after 2 U, hemoglobin, serum iron and ferritin, total iron binding force, transferrin saturation were higher before a blood transfusion, differences were statistically significant; iron overload 2 U group before and after blood transfusion hemoglobin, serum iron and ferritin, total iron binding force, transferrin saturation change significantly greater than Insufficient iron reserves 2

  15. Polyurethane biocompatible silver bionanocomposites for biomedical applications

    Science.gov (United States)

    Filip, D.; Macocinschi, D.; Paslaru, E.; Munteanu, B. S.; Dumitriu, R. P.; Lungu, M.; Vasile, C.

    2014-11-01

    Bionanocomposite membranes based on polyurethane (PU), extracellular matrix (EM), and silver nanoparticles (AgNPs) were prepared by applying both solvent casting method and electrospinning/electrospraying method. PU-EM-Ag compositions were electrospun/electrosprayed onto PU membrane to realize improved biocompatible biomaterials. Surface morphological characteristics and wettability properties were investigated by SEM and AFM techniques and water contact angle measurements. Water contact angle depends on surface chemistry and the two methods employed for preparation of biomembranes as well as roughness of the membrane surfaces. Rheological study brings information on electrospinability of the polymer solutions/dispersions. Silver nanoparticles greatly influence the electrospinability of the polymer dispersions because of the increase in dynamic viscosity with the increasing silver content. Native PU and PU incorporated with low contents of AgNPs less than 0.3 % show high cell proliferation and good biocompatibility. The electrospun PU-EM-Ag nanobiocomposite membranes bring the advantage of using of low amounts of bioactive and biocidal components. The obtained silver nanobiocomposite membranes possess good bioactivity and non-cytotoxicity necessary for biomedical device applications. The obtained nanobiocomposite membranes are expected to find application for medical devices such as urinary catheters, wound dressings, etc.

  16. Biocompatibility of polymethylmethacrylate resins used in dentistry.

    Science.gov (United States)

    Gautam, Rupali; Singh, Raghuwar D; Sharma, Vinod P; Siddhartha, Ramashanker; Chand, Pooran; Kumar, Rakesh

    2012-07-01

    Biocompatibility or tissue compatibility describes the ability of a material to perform with an appropriate host response when applied as intended. Poly-methylmethacrylate (PMMA) based resins are most widely used resins in dentistry, especially in fabrication of dentures and orthodontic appliances. They are considered cytotoxic on account of leaching of various potential toxic substances, most common being residual monomer. Various in vitro and in vivo experiments and cell based studies conducted on acrylic based resins or their leached components have shown them to have cytotoxic effects. They can cause mucosal irritation and tissue sensitization. These studies are not only important to evaluate the long term clinical effect of these materials, but also help in further development of alternate resins. This article reviews information from scientific full articles, reviews, or abstracts published in dental literature, associated with biocompatibility of PMMA resins and it is leached out components. Published materials were searched in dental literature using general and specialist databases, like the PubMED database.

  17. Biocompatibility of Soft-Templated Mesoporous Carbons

    Energy Technology Data Exchange (ETDEWEB)

    Gencoglu, Maria F. [Michigan Technological Univ., Houghton, MI (United States). Dept. of Chemical Engineering; Spurri, Amanda [Widener Univ., Chester, PA (United States). Dept. of Chemical Engineering; Franko, Mitchell [Widener Univ., Chester, PA (United States). Dept. of Chemical Engineering; Chen, Jihua [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States). Center for Nanophase Materials Science (CNMS); Hensley, Dale K. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States). Center for Nanophase Materials Science (CNMS); Heldt, Caryn L. [Michigan Technological Univ., Houghton, MI (United States). Dept. of Chemical Engineering; Saha, Dipendu [Widener Univ., Chester, PA (United States). Dept. of Chemical Engineering

    2014-08-21

    We report that soft-templated mesoporous carbon is morphologically a non-nano type of carbon. It is a relatively newer variety of biomaterial, which has already demonstrated its successful role in drug delivery applications. To investigate the toxicity and biocompatibility, we introduced three types of mesoporous carbons with varying synthesis conditions and pore textural properties. We compared the Brunauer–Emmett–Teller (BET) surface area and pore width and performed cytotoxicity experiments with HeLa cells, cell viability studies with fibroblast cells and hemocomapatibility studies. Cytotoxicity tests reveal that two of the carbons are not cytotoxic, with cell survival over 90%. The mesoporous carbon with the highest surface area showed slight toxicity (~70% cell survival) at the highest carbon concentration of 500 μg/mL. Fibroblast cell viability assays suggested high and constant viability of over 98% after 3 days with no apparent relation with materials property and good visible cell-carbon compatibility. No hemolysis (<1%) was confirmed for all the carbon materials. Protein adsorption experiments with bovine serum albumin (BSA) and fibrinogen revealed a lower protein binding capacity of 0.2–0.6 mg/m2 and 2–4 mg/m2 for BSA and fibrinogen, respectively, with lower binding associated with an increase in surface area. The results of this study confirm the biocompatibility of soft-templated mesoporous carbons.

  18. Antimicrobial and biocompatible properties of nanomaterials.

    Science.gov (United States)

    Ul-Islam, M; Shehzad, A; Khan, S; Khattak, W A; Ullah, M W; Park, J K

    2014-01-01

    The rapid development of drug-resistant characteristics in pathogenic viral, bacterial, and fungal species and the consequent spread of infectious diseases are currently receiving serious attention. Indeed, there is a pressing demand to explore novel materials and develop new strategies that can address these issues of serious concern. Nanomaterials are currently proving to be the most capable therapeutic agents to cope with such hazards. The exceptional physiochemical properties and impressive antimicrobial capabilities of nanoparticles have provoked their utilization in biomedical fields. Nanomaterials of both organic and inorganic nature have shown the capabilities of disrupting microbial cells through different mechanisms. Along with the direct influence on the microbial cell membrane, DNA and proteins, these nanomaterials produce reactive oxygen species (ROS) that damage cell components and viruses. Currently, a serious hazard associated with these antimicrobial nanomaterials is their toxicity to human and animal cells. Extensive studies have reported the dose, time, and cell-dependent toxicology of various nanomaterials, and some have shown excellent biocompatible properties. Nevertheless, there is still debate regarding the use of nanomaterials for medical applications. Therefore, in this review, the antimicrobial activities of various nanomaterials with details of their acting mechanisms were compiled. The relative toxic and biocompatible behavior of nanomaterials emphasized in this study provides information pertaining to their practical applicability in medical fields.

  19. A numerical performance assessment of a commercial cardiopulmonary by-pass blood heat exchanger.

    Science.gov (United States)

    Consolo, Filippo; Fiore, Gianfranco B; Pelosi, Alessandra; Reggiani, Stefano; Redaelli, Alberto

    2015-06-01

    We developed a numerical model, based on multi-physics computational fluid dynamics (CFD) simulations, to assist the design process of a plastic hollow-fiber bundle blood heat exchanger (BHE) integrated within the INSPIRE(TM), a blood oxygenator (OXY) for cardiopulmonary by-pass procedures, recently released by Sorin Group Italia. In a comparative study, we analyzed five different geometrical design solutions of the BHE module. Quantitative geometrical-dependent parameters providing a comprehensive evaluation of both the hemo- and thermo-dynamics performance of the device were extracted to identify the best-performing prototypical solution. A convenient design configuration was identified, characterized by (i) a uniform blood flow pattern within the fiber bundle, preventing blood flow shunting and the onset of stagnation/recirculation areas and/or high velocity pathways, (ii) an enhanced blood heating efficiency, and (iii) a reduced blood pressure drop. The selected design configuration was then prototyped and tested to experimentally characterize the device performance. Experimental results confirmed numerical predictions, proving the effectiveness of CFD modeling as a reliable tool for in silico identification of suitable working conditions of blood handling medical devices. Notably, the numerical approach limited the need for extensive prototyping, thus reducing the corresponding machinery costs and time-to-market.

  20. Facile preparation of heparinized polysulfone membrane assisted by polydopamine/polyethyleneimine co-deposition for simultaneous LDL selectivity and biocompatibility

    Science.gov (United States)

    Wang, Liwei; Fang, Fei; Liu, Yang; Li, Jing; Huang, Xiaojun

    2016-11-01

    Low-density lipoprotein (LDL) gains worldwide attention for decades as the key risk factor to atherosclerosis that progressively deteriorating into cardiovascular diseases. Until recent years, LDL-apheresis comes to be extensively used as a direct and efficient LDL removal method, with LDL adsorption materials particularly important. In this paper, a new strategy based on the co-deposition of polydopamine (PDA) with polyethylenimine (PEI) onto polysulfone (PSf) membranes, then subsequent heparinization by amino-carbonyl reactions, to achieve LDL selectivity and simultaneous biocompatibility, is proposed. Surface properties of modified PSf membranes are characterized by ATR-FTIR, XPS, FESEM, Zeta potential and WCA measurements. LDL adsorption ability is investigated by ELISA, while blood biocompatibility is evaluated by platelet adhesion experiments. Results suggest that heparin-modified PSf membranes show high selectivity for LDL removal and fine biocompatibility in contact with plasma, as excellent potential materials for LDL-apheresis.

  1. EURASIAN MINERAL WATER: MATHEMATICAL MODELING, CLASSIFICATION AND ASSESSMENT OF THEIR IMPACT ON THE BIOCHEMICAL COMPOSITION OF HUMAN BLOOD

    Directory of Open Access Journals (Sweden)

    Nikolay Kornilov

    2014-06-01

    Full Text Available In the article the results of comparative analysis of the composition of the Eurasian hydromineral resources and the assessment of their impact on the physiological condition of a human organism according to biochemical studies of venous blood are presented. Processing of initial data on the composition and properties of mineral waters chloride-hydrocarbonate, sulphate- hydrocarbonate and chloride-sulphate types and venous blood are made using the method of mathematical modeling, developed by the authors of this article. It is shown that in the balneological impact of hydromineral resources on the body in the blood increases the hemoglobin and oxygen, decreases glucose, and acid-base pH shifted to high alkalinity.

  2. Melanin and blood concentration in a human skin model studied by multiple regression analysis: assessment by Monte Carlo simulation

    Science.gov (United States)

    Shimada, M.; Yamada, Y.; Itoh, M.; Yatagai, T.

    2001-09-01

    Measurement of melanin and blood concentration in human skin is needed in the medical and the cosmetic fields because human skin colour is mainly determined by the colours of melanin and blood. It is difficult to measure these concentrations in human skin because skin has a multi-layered structure and scatters light strongly throughout the visible spectrum. The Monte Carlo simulation currently used for the analysis of skin colour requires long calculation times and knowledge of the specific optical properties of each skin layer. A regression analysis based on the modified Beer-Lambert law is presented as a method of measuring melanin and blood concentration in human skin in a shorter period of time and with fewer calculations. The accuracy of this method is assessed using Monte Carlo simulations.

  3. Implementation of laser speckle contrast analysis as connection kit for mobile phone for assessment of skin blood flow

    Science.gov (United States)

    Jakovels, Dainis; Saknite, Inga; Spigulis, Janis

    2014-05-01

    Laser speckle contrast analysis (LASCA) offers a non-contact, full-field, and real-time mapping of capillary blood flow and can be considered as an alternative method to Laser Doppler perfusion imaging. LASCA technique has been implemented in several commercial instruments. However, these systems are still too expensive and bulky to be widely available. Several optical techniques have found new implementations as connection kits for mobile phones thus offering low cost screening devices. In this work we demonstrate simple implementation of LASCA imaging technique as connection kit for mobile phone for primary low-cost assessment of skin blood flow. Stabilized 650 nm and 532 nm laser diode modules were used for LASCA illumination. Dual wavelength illumination could provide additional information about skin hemoglobin and oxygenation level. The proposed approach was tested for arterial occlusion and heat test. Besides, blood flow maps of injured and provoked skin were demonstrated.

  4. The immobilization of recombinant human tropoelastin on metals using a plasma-activated coating to improve the biocompatibility of coronary stents.

    Science.gov (United States)

    Waterhouse, Anna; Yin, Yongbai; Wise, Steven G; Bax, Daniel V; McKenzie, David R; Bilek, Marcela M M; Weiss, Anthony S; Ng, Martin K C

    2010-11-01

    Current endovascular stents have sub-optimal biocompatibility reducing their clinical efficacy. We previously demonstrated a plasma-activated coating (PAC) that covalently bound recombinant human tropoelastin (TE), a major regulator of vascular cells in vivo, to enhance endothelial cell interactions. We sought to develop this coating to enhance its mechanical properties and hemocompatibility for application onto coronary stents. The plasma vapor composition was altered by incorporating argon, nitrogen, hydrogen or oxygen to modulate coating properties. Coatings were characterized for 1) surface properties, 2) mechanical durability, 3) covalent protein binding, 4) endothelial cell interactions and 5) thrombogenicity. The N(2)/Ar PAC had optimal mechanical properties and did not delaminate after stent expansion. The N(2)/Ar PAC was mildly hydrophilic and covalently bound the highest proportion of TE, which enhanced endothelial cell proliferation. Acute thrombogenicity was assessed in a modified Chandler loop using human blood. Strikingly, the N(2)/Ar PAC alone reduced thrombus weight by ten-fold compared to 316L SS, a finding unaltered with immobilized TE. Serum soluble P-selectin was reduced on N(2)/Ar PAC and N(2)/Ar PAC + TE (p < 0.05), consistent with reduced platelet activation. We have demonstrated a coating for metal alloys with multifaceted biocompatibility that resists delamination and is non-thrombogenic, with implications for improving coronary stent efficacy.

  5. Orthostatic leg blood volume changes assessed by near-infrared spectroscopy

    DEFF Research Database (Denmark)

    Truijen, J; Kim, Y S; Krediet, C T P

    2012-01-01

    posture, volume accumulation in small blood vessels contributes significantly to the total fluid volume accumulated in the legs. Considering that near-infrared spectroscopy (NIRS) tracks postural blood volume changes within the small blood vessels of the lower leg, we evaluated the NIRS-determined changes...... separate days (n = 8). In response to HUT, an initially fast increase in [O(2)Hb] was followed by a gradual decline, while [HHb] increased continuously. The increase in [tHb] during HUT was closely related to the increase in total leg volume (r(2) = 0.95 ± 0.03). After tilt back, [O(2)Hb] declined below...

  6. Quantitative assessment of the impact of blood pulsation on images of the pupil in infrared light.

    Science.gov (United States)

    Koprowski, Robert; Szmigiel, Marta; Kasprzak, Henryk; Wróbel, Zygmunt; Wilczyński, Sławomir

    2015-08-01

    Pulsation in the blood vessels of the eye has a big impact on the dynamics of the entire eyeball and its individual elements. Blood pulsation in the retina can be recorded by the pupil, whose size is also subject to dynamic changes. The study involved synchronous measurements of pupil size using a high-speed camera, and blood pulsation using a pulse oximeter placed on the ear lobe. In addition, there were no metrologically significant differences in the phase shift between the average brightness of the individual pupil quadrants. Blood pulsation in other ocular tissues can affect the dynamics of the optical properties of the eye. As demonstrated in this paper, it affects the pupil behavior and its parameters to a considerable extent.

  7. Angiostrongylosis-related restrictive pneumopathy assessed by arterial blood gas analysis in a dog.

    Science.gov (United States)

    Csöndes, Judit; Majoros, Gábor; Lajos, Zoltán; Psáder, Roland; Vajdovich, Péter; Manczur, Ferenc; Máthé, Ákos

    2015-03-01

    Pulmonary angiostrongylosis was diagnosed by the Baermann method and larval identification from faecal and bronchoalveolar lavage samples in a five-month- old male mongrel dog with dyspnoea and cough. Arterial blood gas analysis indicated arterial hypoxaemia and restrictive pneumopathy. In addition to the palliative treatment, fenbendazole was administered (50 mg/kg/24 h per os) for 14 days. The respiratory signs subsided within a short time clinically, but serial arterial blood gas analysis demonstrated an ongoing ventilation disorder. Repeated haematology, thoracic radiography, bronchoscopy and blood gas analysis were performed to follow the course of the disease. The most severe eosinophilia was detected after the beginning of the anthelmintic therapy, and the arterial pO2 level was permanently low. Arterial blood gas analysis provided the most adequate information about the course of the pneumopathy and it greatly facilitated the patient's medical management.

  8. An assessment of contemporary atomic spectroscopic techniques for the determination of lead in blood and urine matrices

    Science.gov (United States)

    Parsons, Patrick J.; Geraghty, Ciaran; Verostek, Mary Frances

    2001-09-01

    The preparation and validation of a number of clinical reference materials for the determination of lead in blood and urine is described. Four candidate blood lead reference materials (Lots, 047-050), and four candidate urine lead reference materials (Lots, 034, 035, 037 and 038), containing physiologically-bound lead at clinically relevant concentrations, were circulated to up to 21 selected laboratories specializing in this analysis. Results from two interlaboratory studies were used to establish certified values and uncertainty estimates for these reference materials. These data also provided an assessment of current laboratory techniques for the measurement of lead in blood and urine. For the blood lead measurements, four laboratories used electrothermal atomization AAS, three used anodic stripping voltammetry and one used both ETAAS and ICP-MS. For the urine lead measurements, 11 laboratories used ETAAS (most with Zeeman background correction) and 10 used ICP-MS. Certified blood lead concentrations, ±S.D., ranged from 5.9±0.4 μg/dl (0.28±0.02 μmol/l) to 76.0±2.2 μg/dl (3.67±0.11 μmol/l) and urine lead concentrations ranged from 98±5 μg/l (0.47±0.02 μmol/l) to 641±36 μg/l (3.09±0.17 μmol/l). The highest concentration blood lead material was subjected to multiple analyses using ETAAS over an extended time period. The data indicate that more stringent internal quality control practices are necessary to improve long-term precision. While the certification of blood lead materials was accomplished in a manner consistent with established practices, the urine lead materials proved more troublesome, particularly at concentrations above 600 μg/l (2.90 μmol/l).

  9. The 2014 Canadian Hypertension Education Program recommendations for blood pressure measurement, diagnosis, assessment of risk, prevention, and treatment of hypertension.

    Science.gov (United States)

    Dasgupta, Kaberi; Quinn, Robert R; Zarnke, Kelly B; Rabi, Doreen M; Ravani, Pietro; Daskalopoulou, Stella S; Rabkin, Simon W; Trudeau, Luc; Feldman, Ross D; Cloutier, Lyne; Prebtani, Ally; Herman, Robert J; Bacon, Simon L; Gilbert, Richard E; Ruzicka, Marcel; McKay, Donald W; Campbell, Tavis S; Grover, Steven; Honos, George; Schiffrin, Ernesto L; Bolli, Peter; Wilson, Thomas W; Lindsay, Patrice; Hill, Michael D; Coutts, Shelagh B; Gubitz, Gord; Gelfer, Mark; Vallée, Michel; Prasad, G V Ramesh; Lebel, Marcel; McLean, Donna; Arnold, J Malcolm O; Moe, Gordon W; Howlett, Jonathan G; Boulanger, Jean-Martin; Larochelle, Pierre; Leiter, Lawrence A; Jones, Charlotte; Ogilvie, Richard I; Woo, Vincent; Kaczorowski, Janusz; Burns, Kevin D; Petrella, Robert J; Hiremath, Swapnil; Milot, Alain; Stone, James A; Drouin, Denis; Lavoie, Kim L; Lamarre-Cliche, Maxime; Tremblay, Guy; Hamet, Pavel; Fodor, George; Carruthers, S George; Pylypchuk, George B; Burgess, Ellen; Lewanczuk, Richard; Dresser, George K; Penner, S Brian; Hegele, Robert A; McFarlane, Philip A; Khara, Milan; Pipe, Andrew; Oh, Paul; Selby, Peter; Sharma, Mukul; Reid, Debra J; Tobe, Sheldon W; Padwal, Raj S; Poirier, Luc

    2014-05-01

    Herein, updated evidence-based recommendations for the diagnosis, assessment, prevention, and treatment of hypertension in Canadian adults are detailed. For 2014, 3 existing recommendations were modified and 2 new recommendations were added. The following recommendations were modified: (1) the recommended sodium intake threshold was changed from ≤ 1500 mg (3.75 g of salt) to approximately 2000 mg (5 g of salt) per day; (2) a pharmacotherapy treatment initiation systolic blood pressure threshold of ≥ 160 mm Hg was added in very elderly (age ≥ 80 years) patients who do not have diabetes or target organ damage (systolic blood pressure target in this population remains at hypertension to only those ≥ 50 years of age. The 2 new recommendations are: (1) advice to be cautious when lowering systolic blood pressure to target levels in patients with established coronary artery disease if diastolic blood pressure is ≤ 60 mm Hg because of concerns that myocardial ischemia might be exacerbated; and (2) the addition of glycated hemoglobin (A1c) in the diagnostic work-up of patients with newly diagnosed hypertension. The rationale for these recommendation changes is discussed. In addition, emerging data on blood pressure targets in stroke patients are discussed; these data did not lead to recommendation changes at this time. The Canadian Hypertension Education Program recommendations will continue to be updated annually.

  10. [Numerical assessment of impeller features of centrifugal blood pump based on fast hemolysis approximation model].

    Science.gov (United States)

    Shou, Chen; Guo, Yongjun; Su, Lei; Li, Yongqian

    2014-12-01

    The impeller profile, which is one of the most important factors, determines the creation of shear stress which leads to blood hemolysis in the internal flow of centrifugal blood pump. The investigation of the internal flow field in centrifugal blood pump and the estimation of the hemolysis within different impeller profiles will provide information to improve the performance of centrifugal blood pump. The SST kappa-omega with low Reynolds correction was used in our laboratory to study the internal flow fields for four kinds of impellers of centrifugal blood pump. The flow fields included distributions of pressure field, velocity field and shear stress field. In addition, a fast numerical hemolysis approximation was adopted to calculate the normalized index of hemolysis (NIH). The results indicated that the pressure field distribution in all kinds of blood pump were reasonable, but for the log spiral impeller pump, the vortex and backflow were much lower than those of the other pumps, and the high shear stress zone was just about 0.004%, and the NIH was 0.0089.

  11. Chitosan-coated mesoporous MIL-100(Fe) nanoparticles as improved bio-compatible oral nanocarriers

    Science.gov (United States)

    Hidalgo, T.; Giménez-Marqués, M.; Bellido, E.; Avila, J.; Asensio, M. C.; Salles, F.; Lozano, M. V.; Guillevic, M.; Simón-Vázquez, R.; González-Fernández, A.; Serre, C.; Alonso, M. J.; Horcajada, P.

    2017-03-01

    Nanometric biocompatible Metal-Organic Frameworks (nanoMOFs) are promising candidates for drug delivery. Up to now, most studies have targeted the intravenous route, related to pain and severe complications; whereas nanoMOFs for oral administration, a commonly used non-invasive and simpler route, remains however unexplored. We propose here the biofriendly preparation of a suitable oral nanocarrier based on the benchmarked biocompatible mesoporous iron(III) trimesate nanoparticles coated with the bioadhesive polysaccharide chitosan (CS). This method does not hamper the textural/structural properties and the sorption/release abilities of the nanoMOFs upon surface engineering. The interaction between the CS and the nanoparticles has been characterized through a combination of high resolution soft X-ray absorption and computing simulation, while the positive impact of the coating on the colloidal and chemical stability under oral simulated conditions is here demonstrated. Finally, the intestinal barrier bypass capability and biocompatibility of CS-coated nanoMOF have been assessed in vitro, leading to an increased intestinal permeability with respect to the non-coated material, maintaining an optimal biocompatibility. In conclusion, the preservation of the interesting physicochemical features of the CS-coated nanoMOF and their adapted colloidal stability and progressive biodegradation, together with their improved intestinal barrier bypass, make these nanoparticles a promising oral nanocarrier.

  12. Soft and Stretchable Sensor Using Biocompatible Electrodes and Liquid for Medical Applications

    Science.gov (United States)

    Ranzani, Tommaso; Liu, Hongbin; Nefti-Meziani, Samia; Althoefer, Kaspar; Menciassi, Arianna

    2015-01-01

    Abstract This article introduces a soft and stretchable sensor composed of silicone rubber integrating a conductive liquid-filled channel with a biocompatible sodium chloride (NaCl) solution and novel stretchable gold sputtered electrodes to facilitate the biocompatibility of the sensor. By stretching the sensor, the cross section of the channel deforms, thus leading to a change in electrical resistance. The functionalities of the sensor have been validated experimentally: changes in electrical resistance are measured as a function of the applied strain. The experimentally measured values match theoretical predictions, showing relatively low hysteresis. A preliminary assessment on the proposed sensor prototype shows good results with a maximum tested strain of 64%. The design optimization of the saline solution, the electrodes, and the algebraic approximations derived for integrating the sensors in a flexible manipulator for surgery has been discussed. The contribution of this article is the introduction of the biocompatible and stretchable gold sputtered electrodes integrated with the NaCl-filled channel rubber as a fully biocompatible solution for measuring deformations in soft and stretchable medical instruments. PMID:27625915

  13. Chitosan-coated mesoporous MIL-100(Fe) nanoparticles as improved bio-compatible oral nanocarriers

    Science.gov (United States)

    Hidalgo, T.; Giménez-Marqués, M.; Bellido, E.; Avila, J.; Asensio, M. C.; Salles, F.; Lozano, M. V.; Guillevic, M.; Simón-Vázquez, R.; González-Fernández, A.; Serre, C.; Alonso, M. J.; Horcajada, P.

    2017-01-01

    Nanometric biocompatible Metal-Organic Frameworks (nanoMOFs) are promising candidates for drug delivery. Up to now, most studies have targeted the intravenous route, related to pain and severe complications; whereas nanoMOFs for oral administration, a commonly used non-invasive and simpler route, remains however unexplored. We propose here the biofriendly preparation of a suitable oral nanocarrier based on the benchmarked biocompatible mesoporous iron(III) trimesate nanoparticles coated with the bioadhesive polysaccharide chitosan (CS). This method does not hamper the textural/structural properties and the sorption/release abilities of the nanoMOFs upon surface engineering. The interaction between the CS and the nanoparticles has been characterized through a combination of high resolution soft X-ray absorption and computing simulation, while the positive impact of the coating on the colloidal and chemical stability under oral simulated conditions is here demonstrated. Finally, the intestinal barrier bypass capability and biocompatibility of CS-coated nanoMOF have been assessed in vitro, leading to an increased intestinal permeability with respect to the non-coated material, maintaining an optimal biocompatibility. In conclusion, the preservation of the interesting physicochemical features of the CS-coated nanoMOF and their adapted colloidal stability and progressive biodegradation, together with their improved intestinal barrier bypass, make these nanoparticles a promising oral nanocarrier. PMID:28256600

  14. Development of novel biocompatible hybrid nanocomposites based on polyurethane-silica prepared by sol gel process.

    Science.gov (United States)

    Rashti, Ali; Yahyaei, Hossein; Firoozi, Saman; Ramezani, Sara; Rahiminejad, Ali; Karimi, Roya; Farzaneh, Khadijeh; Mohseni, Mohsen; Ghanbari, Hossein

    2016-12-01

    Due to high biocompatibility, polyurethane has found many applications, particularly in development of biomedical devices. A new nanocomposite based on thermoset polyurethane and silica nanoparticles was synthesized using sol-gel method. Sol-gel process was fulfilled in two acidic and basic conditions by using tetraethylorthosilicate (TEOS) and trimethoxyisocyanatesilane as precursors. The hybrid films characterized for mechanical and surface properties using tensile strength, contact angle, ATR-FTIR and scanning electron microscopy. Biocompatibility and cytotoxicity of the hybrids were assessed using standard MTT, LDH and TUNEL assays. The results revealed that incorporation of silica nanoparticles was significantly improved tensile strength and mechanical properties of the hybrids. Based on the contact angle results, silica nanoparticles increased hydrophilicity of the hybrids. Biocompatibility by using human lung epithelial cell line (MRC-5) demonstrated that the hybrids were significantly less cytotoxic compared to pristine polymer as tested by MTT and LDH assays. TUNEL assay revealed no signs of apoptosis in all tested samples. The results of this study demonstrated that incorporation of silica nanoparticles into polyurethane lead to the enhancement of biocompatibility, indicating that these hybrids could potentially be used in biomedical field in particular as a new coating for medical implants.

  15. Modified titanium surface with gelatin nano gold composite increases osteoblast cell biocompatibility

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Young-Hee; Bhattarai, Govinda [Department of Oral Biochemistry, School of Dentistry and Institute of Oral Bioscience, BK21 program, Chonbuk National University, Jeonju (Korea, Republic of); Aryal, Santosh [Department of Bionanosystem Engineering, Chonbuk National University, Jeonju (Korea, Republic of); Lee, Nan-Hee [Department of Oral Biochemistry, School of Dentistry and Institute of Oral Bioscience, BK21 program, Chonbuk National University, Jeonju (Korea, Republic of); Lee, Min-Ho [Department of Dental Biomaterials, School of Dentistry and Institute of Oral Bioscience, BK21 program, Chonbuk National University, Jeonju (Korea, Republic of); Kim, Tae-Gun [Department of Conservative Dentistry, School of Dentistry, Chonbuk National University, Jeonju (Korea, Republic of); Jhee, Eun-Chung [Department of Oral Biochemistry, School of Dentistry and Institute of Oral Bioscience, BK21 program, Chonbuk National University, Jeonju (Korea, Republic of); Kim, Hak-Yong [Department of Bionanosystem Engineering, Chonbuk National University, Jeonju (Korea, Republic of); Yi, Ho-Keun, E-mail: yihokn@chonbuk.ac.kr [Department of Oral Biochemistry, School of Dentistry and Institute of Oral Bioscience, BK21 program, Chonbuk National University, Jeonju (Korea, Republic of)

    2010-08-01

    This study examined the gelatin nano gold (GnG) composite for surface modification of titanium in addition to insure biocompatibility on dental implants or biomaterials. The GnG composite was constructed by gelatin and hydrogen tetrachloroaurate in presence of reducing agent, sodium borohydrate (NabH{sub 4}). The GnG composite was confirmed by UV-VIS spectroscopy and transmission electron microscopy (TEM). A dipping method was used to modify the titanium surface by GnG composite. Surface was characterized by scanning electron microscopy (SEM) and energy dispersive X-ray (EDX). The MC-3T3 E1 cell viability was assessed by trypan blue and the expression of proteins to biocompatibility were analyzed by Western blotting. The GnG composite showed well dispersed character, the strong absorption at 530 nm, roughness, regular crystal and clear C, Na, Cl, P, and Au signals onto titanium. Further, this composite allowed MC-3T3 E1 growth and viability compared to gelatin and pure titanium. It induced ERK activation and the expression of cell adherent molecules, FAK and SPARC, and growth factor, VEGF. However, GnG decreased the level of SAPK/JNK. This shows that GnG composite coated titanium surfaces have a good biocompatibility for osteoblast growth and attachment than in intact by simple and versatile dipping method. Furthermore, it offers good communication between cell and implant surfaces by regulating cell signaling and adherent molecules, which are useful to enhance the biocompatibility of titanium surfaces.

  16. Modified titanium surface with gelatin nano gold composite increases osteoblast cell biocompatibility

    Science.gov (United States)

    Lee, Young-Hee; Bhattarai, Govinda; Aryal, Santosh; Lee, Nan-Hee; Lee, Min-Ho; Kim, Tae-Gun; Jhee, Eun-Chung; Kim, Hak-Yong; Yi, Ho-Keun

    2010-08-01

    This study examined the gelatin nano gold (GnG) composite for surface modification of titanium in addition to insure biocompatibility on dental implants or biomaterials. The GnG composite was constructed by gelatin and hydrogen tetrachloroaurate in presence of reducing agent, sodium borohydrate (NabH 4). The GnG composite was confirmed by UV-VIS spectroscopy and transmission electron microscopy (TEM). A dipping method was used to modify the titanium surface by GnG composite. Surface was characterized by scanning electron microscopy (SEM) and energy dispersive X-ray (EDX). The MC-3T3 E1 cell viability was assessed by trypan blue and the expression of proteins to biocompatibility were analyzed by Western blotting. The GnG composite showed well dispersed character, the strong absorption at 530 nm, roughness, regular crystal and clear C, Na, Cl, P, and Au signals onto titanium. Further, this composite allowed MC-3T3 E1 growth and viability compared to gelatin and pure titanium. It induced ERK activation and the expression of cell adherent molecules, FAK and SPARC, and growth factor, VEGF. However, GnG decreased the level of SAPK/JNK. This shows that GnG composite coated titanium surfaces have a good biocompatibility for osteoblast growth and attachment than in intact by simple and versatile dipping method. Furthermore, it offers good communication between cell and implant surfaces by regulating cell signaling and adherent molecules, which are useful to enhance the biocompatibility of titanium surfaces.

  17. The biocompatibility of porous vs non-porous bone cements: a new methodological approach

    Directory of Open Access Journals (Sweden)

    C. Dall'Oca

    2014-06-01

    Full Text Available Composite cements have been shown to be biocompatible, bioactive, with good mechanical properties and capability to bind to the bone. Despite these interesting characteristic, in vivo studies on animal models are still incomplete and ultrastructural data are lacking. The acquisition of new ultrastructural data is hampered by uncertainties in the methods of preparation of histological samples due to the use of resins that melt methacrylate present in bone cement composition. A new porous acrylic cement composed of polymethylmetacrylate (PMMA and β-tricalciumphosphate (β-TCP was developed and tested on an animal model. The cement was implanted in femurs of 8 New Zealand White rabbits, which were observed for 8 weeks before their sacrifice. Histological samples were prepared with an infiltration process of LR white resin and then the specimens were studied by X-rays, histology and scanning electron microscopy (SEM. As a control, an acrylic standard cement, commonly used in clinical procedures, was chosen. Radiographic ultrastructural and histological exams have allowed finding an excellent biocompatibility of the new porous cement. The high degree of osteointegration was demonstrated by growth of neo-created bone tissue inside the cement sample. Local or systemic toxicity signs were not detected. The present work shows that the proposed procedure for the evaluation of biocompatibility, based on the use of LR white resin allows to make a thorough and objective assessment of the biocompatibility of porous and non-porous bone cements.

  18. Biocompatibility of Advanced Manufactured Titanium Implants—A Review

    Directory of Open Access Journals (Sweden)

    Alfred T. Sidambe

    2014-12-01

    Full Text Available Titanium (Ti and its alloys may be processed via advanced powder manufacturing routes such as additive layer manufacturing (or 3D printing or metal injection moulding. This field is receiving increased attention from various manufacturing sectors including the medical devices sector. It is possible that advanced manufacturing techniques could replace the machining or casting of metal alloys in the manufacture of devices because of associated advantages that include design flexibility, reduced processing costs, reduced waste, and the opportunity to more easily manufacture complex or custom-shaped implants. The emerging advanced manufacturing approaches of metal injection moulding and additive layer manufacturing are receiving particular attention from the implant fabrication industry because they could overcome some of the difficulties associated with traditional implant fabrication techniques such as titanium casting. Using advanced manufacturing, it is also possible to produce more complex porous structures with improved mechanical performance, potentially matching the modulus of elasticity of local bone. While the economic and engineering potential of advanced manufacturing for the manufacture of musculo-skeletal implants is therefore clear, the impact on the biocompatibility of the materials has been less investigated. In this review, the capabilities of advanced powder manufacturing routes in producing components that are suitable for biomedical implant applications are assessed with emphasis placed on surface finishes and porous structures. Given that biocompatibility and host bone response are critical determinants of clinical performance, published studies of in vitro and in vivo research have been considered carefully. The review concludes with a future outlook on advanced Ti production for biomedical implants using powder metallurgy.

  19. Biocompatibility of Advanced Manufactured Titanium Implants—A Review

    Science.gov (United States)

    Sidambe, Alfred T.

    2014-01-01

    Titanium (Ti) and its alloys may be processed via advanced powder manufacturing routes such as additive layer manufacturing (or 3D printing) or metal injection moulding. This field is receiving increased attention from various manufacturing sectors including the medical devices sector. It is possible that advanced manufacturing techniques could replace the machining or casting of metal alloys in the manufacture of devices because of associated advantages that include design flexibility, reduced processing costs, reduced waste, and the opportunity to more easily manufacture complex or custom-shaped implants. The emerging advanced manufacturing approaches of metal injection moulding and additive layer manufacturing are receiving particular attention from the implant fabrication industry because they could overcome some of the difficulties associated with traditional implant fabrication techniques such as titanium casting. Using advanced manufacturing, it is also possible to produce more complex porous structures with improved mechanical performance, potentially matching the modulus of elasticity of local bone. While the economic and engineering potential of advanced manufacturing for the manufacture of musculo-skeletal implants is therefore clear, the impact on the biocompatibility of the materials has been less investigated. In this review, the capabilities of advanced powder manufacturing routes in producing components that are suitable for biomedical implant applications are assessed with emphasis placed on surface finishes and porous structures. Given that biocompatibility and host bone response are critical determinants of clinical performance, published studies of in vitro and in vivo research have been considered carefully. The review concludes with a future outlook on advanced Ti production for biomedical implants using powder metallurgy. PMID:28788296

  20. Biocompatibility of Advanced Manufactured Titanium Implants-A Review.

    Science.gov (United States)

    Sidambe, Alfred T

    2014-12-19

    Titanium (Ti) and its alloys may be processed via advanced powder manufacturing routes such as additive layer manufacturing (or 3D printing) or metal injection moulding. This field is receiving increased attention from various manufacturing sectors including the medical devices sector. It is possible that advanced manufacturing techniques could replace the machining or casting of metal alloys in the manufacture of devices because of associated advantages that include design flexibility, reduced processing costs, reduced waste, and the opportunity to more easily manufacture complex or custom-shaped implants. The emerging advanced manufacturing approaches of metal injection moulding and additive layer manufacturing are receiving particular attention from the implant fabrication industry because they could overcome some of the difficulties associated with traditional implant fabrication techniques such as titanium casting. Using advanced manufacturing, it is also possible to produce more complex porous structures with improved mechanical performance, potentially matching the modulus of elasticity of local bone. While the economic and engineering potential of advanced manufacturing for the manufacture of musculo-skeletal implants is therefore clear, the impact on the biocompatibility of the materials has been less investigated. In this review, the capabilities of advanced powder manufacturing routes in producing components that are suitable for biomedical implant applications are assessed with emphasis placed on surface finishes and porous structures. Given that biocompatibility and host bone response are critical determinants of clinical performance, published studies of in vitro and in vivo research have been considered carefully. The review concludes with a future outlook on advanced Ti production for biomedical implants using powder metallurgy.

  1. Assessment of carbon monoxide values in smokers: a comparison of carbon monoxide in expired air and carboxyhaemoglobin in arterial blood

    DEFF Research Database (Denmark)

    Andersson, Mette F; Møller, Ann M

    2010-01-01

    Smoking increases perioperative complications. Carbon monoxide concentrations can estimate patients' smoking status and might be relevant in preoperative risk assessment. In smokers, we compared measurements of carbon monoxide in expired air (COexp) with measurements of carboxyhaemoglobin (COHb) ......) in arterial blood. The objectives were to determine the level of correlation and to determine whether the methods showed agreement and evaluate them as diagnostic tests in discriminating between heavy and light smokers....

  2. Significant and sustaining elevation of blood oxygen induced by Chinese cupping therapy as assessed by near-infrared spectroscopy

    OpenAIRE

    Li, Ting; Li, Yaoxian; Lin, Yu; Li, Kai

    2016-01-01

    Cupping therapy has been used in traditional Chinese medicine for thousands of years to relieve muscle pain/tendency/fatigue and to cure or reduce symbols of other diseases. However, its therapeutic effect is sparsely interpreted in the language of modern physiology. To objectively evaluate its therapeutic effect, we focused on dry cupping treatment and utilized near-infrared spectroscopy (NIRS) to assess the concentration change in oxy-hemoglobin ([HbO2]), deoxy-hemoglobin ([Hb]), and blood ...

  3. Biocompatibility of KLD-12 Peptide Hydrogel as a Scaffold in Tissue Engineering of Intervertebral Discs in Rabbits

    Institute of Scientific and Technical Information of China (English)

    孙建华; 郑启新; 吴永超; 刘郁东; 郭晓东; 伍卫刚

    2010-01-01

    KLD-12 peptide with a sequence of AcN-KLDLKLDLKLDL-CNH2 was synthesized and its biocompatibility was assessed in animals.Rabbit MSCs were cultured in the hydrogel for 2 weeks.Live cells were counted by using Calcein-AM/PI fluorescence staining.MTT was employed to assess the viability of MSCs cultured in KLD-12 peptide solution of 0.01%,0.03%,and 0.05%.Hemolysis test,skin irritation test and implantation test were conducted to evaluate its biocompatibility with host tissues.Our results demonstrated that the ...

  4. Si-based Nanoparticles: a biocompatibility study

    Science.gov (United States)

    Rivolta, I.; Lettiero, B.; Panariti, A.; D'Amato, R.; Maurice, V.; Falconieri, M.; Herlein, N.; Borsella, E.; Miserocchi, G.

    2010-10-01

    Exposure to silicon nanoparticles (Si-NPs) may occur in professional working conditions or for people undergoing a diagnostic screening test. Despite the fact that silicon is known as a non-toxic material, in the first case the risk is mostly related to the inhalation of nanoparticles, thus the most likely route of entry is across the lung alveolar epithelium. In the case of diagnostic imaging, nanoparticles are usually injected intravenously and Si-NPs could impact on the endothelial wall. In our study we investigated the interaction between selected Si-based NPs and an epithelial lung cell line. Our data showed that, despite the overall silicon biocompatibility, however accurate studies of the potential toxicity induced by the nanostructure and engineered surface characteristics need to be accurately investigated before Si nanoparticles can be safely used for in vivo applications as bio-imaging, cell staining and drug delivery.

  5. Jet blown PTFE for control of biocompatibility

    Science.gov (United States)

    Leibner, Evan Scott

    The development of fully hemocompatible cardiovascular biomaterials will have a major impact on the practice of modern medicine. Current artificial surfaces, unlike native vascular surfaces, are not able to control clot and thrombus formation. Protein interactions are an important component in hemocompatibility and can result in decreased patency due to thrombus formation or surface passivation which can improve endothelization. It is believed that controlling these properties, specifically the nanometer sizes of the fibers on the material's surface, will allow for better control of biological responses. The biocompatibility of Teflon, a widely used polymer for vascular grafts, would be improved with nanostructured control of surface features. Due to the difficultly in processing polytetrafluoroethylene (PTFE), it has not been possible to create nanofibrous PTFE surfaces. The novel technique of Jet Blowing allows for the formation of nanostructured PTFE (nPTFE). A systematic investigation into controlling polymer properties by varying the processing conditions of temperature, pressure, and gas used in the Jet Blowing allows for an increased understanding of the effects of plasticization on the material's properties. This fundamental understanding of the material science behind the Jet Blowing process has enabled control of the micro and nanoscale structure of nPTFE. While protein adsorption, a key component of biocompatibility, has been widely studied, it is not fully understood. Major problems in the field of biomaterials include a lack of standard protocols to measure biocompatibility, and inconstant literature on protein adsorption. A reproducible protocol for measuring protein adsorption onto superhydrophobic surfaces (ePTFE and nPTFE) has been developed. Both degassing of PBS buffer solutions and evacuation of the air around the expanded PTFE (ePTFE) prior to contact with protein solutions are essential. Protein adsorption experiments show a four

  6. Characterization and Biocompatibility of Biopolyester Nanofibers

    Directory of Open Access Journals (Sweden)

    Tang Hui Ying

    2009-10-01

    Full Text Available Biodegradable nanofibers are expected to be promising scaffold materials for biomedical engineering, however, biomedical applications require control of the degradation behavior and tissue response of nanofiber scaffolds in vivo. For this purpose, electrospun nanofibers of poly(hydroxyalkanoates (PHAs and poly(lactides (PLAs were subjected to degradation tests in vitro and in vivo. In this review, characterization and biocompatibility of nanofibers derived from PHAs and PLAs are described. In particular, the effects of the crystalline structure of poly[(R-3-hydroxybutyrate], stereocomplex structure of PLA, and monomer composition of PHA on the degradation behaviors are described in detail. These studies show the potential of biodegradable polyester nanofibers as scaffold material, for which suitable degradation rate and regulated interaction with surrounding tissues are required.

  7. Chromatography paper as a low-cost medium for accurate spectrophotometric assessment of blood hemoglobin concentration.

    Science.gov (United States)

    Bond, Meaghan; Elguea, Carlos; Yan, Jasper S; Pawlowski, Michal; Williams, Jessica; Wahed, Amer; Oden, Maria; Tkaczyk, Tomasz S; Richards-Kortum, Rebecca

    2013-06-21

    Anemia affects a quarter of the world's population, and a lack of appropriate diagnostic tools often prevents treatment in low-resource settings. Though the HemoCue 201+ is an appropriate device for diagnosing anemia in low-resource settings, the high cost of disposables ($0.99 per test in Malawi) limits its availability. We investigated using spectrophotometric measurement of blood spotted on chromatography paper as a low-cost (paper, and a bench-top spectrophotometer validated the approach before the development of a low-cost reader. We optimized impregnating paper with chemicals to lyse red blood cells, paper type, drying time, wavelengths measured, and sensitivity to variations in volume of blood, and we validated our approach using patient samples. Lysing the blood cells with sodium deoxycholate dried in Whatman Chr4 chromatography paper gave repeatable results, and the absorbance difference between 528 nm and 656 nm was stable over time in measurements taken up to 10 min after sample preparation. The method was insensitive to the amount of blood spotted on the paper over the range of 5 μL to 25 μL. We created a low-cost, handheld reader to measure the transmission of paper cuvettes at these optimal wavelengths. Training and validating our method with patient samples on both the spectrometer and the handheld reader showed that both devices are accurate to within 2 g dL(-1) of the HemoCue device for 98% and 95% of samples, respectively.

  8. DOSE-DEPENDENT EFFECT OF MOLYBDENUM ON PORCINE BLOOD CELLS: IN VITRO ASSESSMENT

    Directory of Open Access Journals (Sweden)

    Marcela Capcarová

    2013-10-01

    Full Text Available The aim of this study was to examine the effect of molybdenum (Mo on selected haematological parameters of porcine blood in vitro. The samples of blood were treated with an ammonium molybdate (NH46.Mo7O24.4H2O for 4 hours at 37oC in the concentrations 10, 100, and 1000 µg.ml-1 (E1, E2, and E3 group. Blood without Mo addition served as the control (C. Selected haematological parameters (WBC – total white blood cell count, LYM – lymphocyte count, GRA – granulocyte count, RBC – red blood cell count, HGB – haemoglobin, HCT – haematocrit and PLT – platelet count were measured using haematological analyser Abacus junior VET. Significant decrease in WBC, LYM, and GRA in the group with the highest dose of Mo (E3 against other groups (C, E1, and E2 was observed. Other results were not influenced by Mo exposure. Our results suggest that Mo can cause the changes and imbalance in immune system.

  9. Effect of Surface Modification on Microbiol Polyhydroxyalkanoate Films on Biocompatibility

    Institute of Scientific and Technical Information of China (English)

    杨霰霜; 赵锴; 陈金春; 夏彩虹; 陈国强

    2001-01-01

    The purpose of this study was to investigate in vitro biocompatibility of a new type of polymer, polyhydroxybutyrate-co-hexanoate (PHBHHx). The hydrophilicity and biocompatibility were studied with two kinds of enzymes, amylase BAN480L and lipase Novozym388. The degree of hydrophilicity was observed using contact angle measurements. In vitro biocompatibility evaluations were carried out by direct incubation of mouse fibroblast cell line L929 on the polyhydroxyalkanoate (PHA) films. The samples treated with BAN480L showed that the PHA biocompatibility increased while the hydrophilicity decreased. Relative to untreated samples, the number of cells on the Novozym388 modified PHBHHx significant decrease as the hydrophilicity also decreased. The results indicated that other surface characteristics besides hydrophilicity influence the biocompatibility of PHBHHx films.

  10. Biocompatibility of a Self-Assembled Crosslinkable Hyaluronic Acid Nanogel.

    Science.gov (United States)

    Pedrosa, Sílvia Santos; Pereira, Paula; Correia, Alexandra; Moreira, Susana; Rocha, Hugo; Gama, Francisco Miguel

    2016-11-01

    Hyaluronic acid nanogel (HyA-AT) is a redox sensitive crosslinkable nanogel, obtained through the conjugation of a thiolated hydrophobic molecule to the hyaluronic acid chain. Engineered nanogel was studied for its biocompatibility, including immunocompatibility and hemocompatability. The nanogel did not compromise the metabolic activity or cellular membrane integrity of 3T3, microvascular endothelial cells, and RAW 264.7 cell lines, as determined by the 3-[4,5-dimethylthiazol-2-yl]-2,5-diphenyl tetrazolium bromide and lactate dehydrogenase release assays. Also, we didn't observe any apoptotic effect on these cell lines through the Annexin V-FITC test. Furthermore, the nanogel cell internalization was analyzed using murine bone marrow derived macrophages, and the in vivo and ex vivo biodistribution of the Cy5.5 labeled nanogel was monitored using a non-invasive near-infrared fluorescence imaging system. The HyA-AT nanogel exhibits fairly a long half-live in the blood stream, thus showing potential for drug delivery applications.

  11. In vitro biocompatibility evaluation of surface-modified titanium alloys.

    Science.gov (United States)

    Treves, Cristina; Martinesi, Maria; Stio, Maria; Gutiérrez, Alejandro; Jiménez, José Antonio; López, María Francisca

    2010-03-15

    The present work is aimed to evaluate the effects of a surface modification process on the biocompatibility of three vanadium-free titanium alloys with biomedical applications interest. Chemical composition of alloys investigated, in weight %, were Ti-7Nb-6Al, Ti-13Nb-13Zr, and Ti-15Zr-4Nb. An easy and economic method intended to improve the biocompatibiblity of these materials consists in a simple thermal treatment at high temperature, 750 degrees C, in air for different times. The significance of modification of the surface properties to the biological response was studied putting in contact both untreated and thermally treated alloys with human cells in culture, Human Umbilical Vein Endothelial Cells (HUVEC) and Human Peripheral Blood Mononuclear Cells (PBMC). The TNF-alpha release data indicate that thermal treatment improves the biological response of the alloys. The notable enhancement of the surface roughness upon oxidation could be related with the observed reduction of the TNF-alpha levels for treated alloys. A different behavior of the two cell lines may be observed, when adhesion molecules (ICAM-1 and VCAM-1 in HUVEC, ICAM-1, and LFA-1 in PBMC) were determined, PBMC being more sensitive than HUVEC to the contact with the samples. The data also distinguish surface composition and corrosion resistance as significant parameters for the biological response.

  12. Facile synthesis, silanization, and biodistribution of biocompatible quantum dots.

    Science.gov (United States)

    Ma, Nan; Marshall, Ann F; Gambhir, Sanjiv S; Rao, Jianghong

    2010-07-19

    A facile strategy for the synthesis of silica-coated quantum dots (QDs) for in vivo imaging is reported. All the QD synthesis and silanization steps are conducted in water and methanol under mild conditions without involving any organometallic precursors or high-temperature, oxygen-free environments. The as-prepared silica-coated QDs possess high quantum yields and are extremely stable in mouse serum. In addition, the silanization method developed here produces nanoparticles with small sizes that are difficult to achieve via conventional silanization methods. The silica coating helps to prevent the exposure of the QD surface to the biological milieu and therefore increases the biocompatibility of QDs for in vivo applications. Interestingly, the silica-coated QDs exhibit a different biodistribution pattern from that of commercially available Invitrogen QD605 (carboxylate) with a similar size and emission wavelength. The Invitrogen QD605 exhibits predominant liver (57.2% injected dose (ID) g(-1)) and spleen (46.1% ID g(-1)) uptakes 30 min after intravenous injection, whereas the silica-coated QDs exhibit much lower liver (16.2% ID g(-1)) and spleen (3.67% ID g(-1)) uptakes but higher kidney uptake (8.82% ID g(-1)), blood retention (15.0% ID g(-1)), and partial renal clearance. Overall, this straightforward synthetic strategy paves the way for routine and customized synthesis of silica-coated QDs for biological use.

  13. Early nocturnal blood pressure changes in diabetic autonomic neuropathy assessed by Fourier series.

    Science.gov (United States)

    Germano, G; Caparra, A; Valentino, S; Germano, U; Coia, F; Cassone-Faldetta, M; De Mattia, G; Santucci, A; Balsano, F

    1993-08-01

    The 24 h periodic pattern of blood pressure was studied in 44 patients with diabetes mellitus (14 type 1, 30 type 2; mean duration of disease 6.5 +/- 1.8 years) in good metabolic control but with abnormal cardiovascular reflex responses; of these 21 were normotensive and 23 hypertensive. All had abnormal responses to at least two out of four tests: deep breathing, lying to standing, Valsalva manoeuvre and postural hypotension. Two sex- and age-matched groups, consisting of 20 normotensive and 20 hypertensive diabetic patients without dysautonomia, were studied as controls. Each patient underwent ambulatory blood pressure monitoring for at least 24 h, using an auscultatory automatic device. Data were analysed using the sum of three periodic functions (Fourier partial sum). In the diabetic normotensive groups, the absolute blood pressure fell to its night-time minimum more rapidly, and increased to its morning maximum more slowly, in those with abnormal cardiovascular reflexes than in the controls (nightly blood pressure decrease -5.8/-4.7 vs. -3.8/-4.0 mmHg/h; increase 4.7/3.6 vs. 5.9/6.1 mmHg/h). The same behaviour was found in both hypertensive groups but the amplitude of the differences was more marked (blood pressure nocturnal decrease -7.7/-7.1 vs. -4.3/-3.9 mmHg/h; increase 3.2/2.1 vs. 5.8/4.3 mmHg/h). This analysis of 24 h ambulatory blood pressure data may be of value in diagnosis and evaluation of autonomic deficits.

  14. The Influence of Low Platelet Count on Whole Blood Aggregometry Assessed by Multiplate

    DEFF Research Database (Denmark)

    Stissing, Trine; Dridi, Nadia P; Ostrowski, Sisse R;

    2011-01-01

    The Multiplate, a whole blood (WB) platelet function test, has shown promising results identifying patients on antiplatelet therapy at increased risk of rethrombosis. In the present study, the influence of low platelet count on platelet aggregation was analyzed and compared with aggregation results...... in an artificial matrix, platelet-rich plasma (PRP). Heparinized and citrated blood was diluted with autologous plasma to platelet concentrations 200 to 25 × 10(9)/L in WB samples (n = 10) and 200 to 100 × 10(9)/L in PRP samples (n = 7). The platelet aggregation was investigated by the ADP-, ASPI-, COL-, and TRAP...

  15. Potential for error when assessing blood cyanide concentrations in fire victims.

    Science.gov (United States)

    Moriya, F; Hashimoto, Y

    2001-11-01

    The present study explores toxicologic significance of blood cyanide concentrations in fire victims. Headspace gas chromatography was used for cyanide detection. Analysis of blood samples from ten fire victims (postmortem interval = 8 h to 3 to 5 d) detected zero to 11.9 mg/L of cyanide and a large difference in cyanide concentrations among victims. Carboxyhemoglobin (COHb) saturation was in the range of 24.9 to 84.2%. To examine the effects of methemoglobinemia and postmortem interval on blood cyanide concentrations in fire victims, an experiment was carried out using rabbits as the animal model. The rabbits were sacrificed by intramuscular injection of 1 mL/kg 2% potassium cyanide 5 min after intravenous injection of 0.33 mL/kg of 3% sodium nitrite (Group A, n = 3) or physiological saline (Group B, n = 6). Average methemoglobin contents immediately before potassium cyanide administration were 6.9 and 0.8% in Groups A and B, respectively. Average cyanide concentrations in cardiac blood at the time of death were 47.4 and 3.56 mg/L, respectively. When blood-containing hearts of the rabbits (n = 3 for Group B) were left at 46 degrees C for the first 1 h, at 20 to 25 degrees C for the next 23 h and then at 4 degrees C for 48 h, approximately 85 and 46% of the original amounts of blood cyanide disappeared within 24 h in Groups A and B, respectively. After the 72-h storage period, 37 and 10%, respectively, of the original amounts of cyanide remained in the blood. When the other three hearts in Group B were left at 20 to 25 degrees C for the last 48 h without refrigeration, cyanide had disappeared almost completely by the end of the experiment. The present results and those published in the literature demonstrate that the toxic effects of cyanide on fire victims should not be evaluated based solely on the concentration in blood.

  16. Oxygen saturation, red blood cell tissue fraction and speed resolved perfusion - A new optical method for microcirculatory assessment.

    Science.gov (United States)

    Jonasson, Hanna; Fredriksson, Ingemar; Pettersson, Anders; Larsson, Marcus; Strömberg, Tomas

    2015-11-01

    We have developed a new fiber-optic system that combines diffuse reflectance spectroscopy (DRS) and laser Doppler Flowmetry (LDF) for a multi-modal assessment of the microcirculation. Quantitative data is achieved with an inverse Monte Carlo algorithm based on an individually adaptive skin model. The output parameters are calculated from the model and given in absolute units: hemoglobin oxygen saturation (%), red blood cell (RBC) tissue fraction (%), and the speed resolved RBC perfusion separated into three speed regions; 0-1mm/s, 1-10mm/s and above 10mm/s (% mm/s). The aim was to explore microcirculatory parameters using the new optical method, integrating DRS and LDF in a joint skin model, during local heating of the dorsal foot and venous and arterial occlusion of the forearm in 23 healthy subjects (age 20-28years). There were differences in the three speed regions in regard to blood flow changes due to local heating, where perfusion for high speeds increased the most. There was also a high correlation between changes in oxygenation and changes in perfusion for higher speeds. Oxygen saturation at baseline was 44% on foot, increasing to 83% at plateau after heating. The larger increase in perfusion for higher speeds than for lower speeds together with the oxygenation increase during thermal provocation, shows a local thermoregulatory blood flow in presumably arteriolar dermal vessels. In conclusion, there are improved possibilities to assess microcirculation using integrated DRS and LDF in a joint skin model by enabling both oxygenation and speed resolved blood flow assessment simultaneously and in the same skin site. Output parameters in absolute units may also yield new insights about the microcirculatory system.

  17. Dynamic Perfusion CT Assessment of the Blood-Brain Barrier Permeability : First Pass versus Delayed Acquisition

    NARCIS (Netherlands)

    Dankbaar, J. W.; Hom, J.; Schneider, T.; Cheng, S. -C.; Lau, B. C.; van der Schaaf, I.; Virmani, S.; Pohlman, S.; Dillon, W. P.; Wintermark, M.

    2008-01-01

    BACKGROUND AND PURPOSE: The Patlak model has been applied to first-pass perfusion CT (PCT) data to extract information on blood-brain barrier permeability (BBBP) to predict hemorrhagic transformation in patients with acute stroke. However, the Patlak model was originally described for the delayed st

  18. Assessment of malathion and its effects on leukocytes in human blood samples

    Science.gov (United States)

    Sharma, Amit Kumar; Tiwari, Udita; Gaur, Mulayam Singh; Tiwari, Rajeev Kumar

    2016-01-01

    Abstract In the present paper, we report a reproducible, cost effective, fast response method for detection of malathion and its effects on leukocytes in different human blood groups. Spectroscopic methods (UV-Vis spectrometry) and Fourier transform infrared coupled with solid phase extraction were applied for analyzing malathion content in human blood plasma. The spiking levels of malathion in the range of 0.1-1.7 µg/mL were extracted from blood plasma samples using SPE. The present active functional groups (C = O; P-O-C; -OH; P = S) were also characterized. The recovery rate of malathion was 80%±4.5%. The calculated correlation coefficient was 0.9799, indicating the linearity of the results. The limit of detection (LOD) and limit of quantification (LOQ) were (0.1-1.7) µg/mL and (0.3-1.5) µg/mL, respectively. Malathion <1.0 µg/mL showed no significant change while higher levels of malathion exposure (1.5 µg/mL and 3.0 µg/mL) reduced the number of white blood cells. In conclusion, the spectroscopic results may be useful to understand the mechanism of other pesticides such as methyl parathion and parathion.

  19. Assessment of viable bacteria and bacterial DNA in blood and bloodstain specimens stored under various conditions.

    Science.gov (United States)

    Hosokawa-Muto, Junji; Fujinami, Yoshihito; Mizuno, Natsuko

    2013-11-01

    Microbial forensic specimens that are collected at biocrime and bioterrorism scenes include blood, tissue, cloths containing biological fluids, swabs, water, soil, and aerosols. It is preferable that pathogens in such specimens are alive and kept in a steady state. Specimens may be stored for a prolonged period before analysis; therefore, it is important to understand the effect of the storage conditions on the pathogens contained within the specimens. In this study, we prepared blood and bloodstain specimens containing Gram-negative or -positive bacteria, stored the samples for 482 days under various conditions, and measured viable bacterial counts and total bacterial contents in the samples. Viable bacteria were preserved well in the samples stored at -30 and -80 °C, but were diminished or undetectable in the samples stored at 4 °C and room temperature. The total bacterial content was maintained in the blood samples stored at -30 and -80 °C and in the bloodstain samples stored under all temperature conditions, but decreased in the blood samples stored at 4 °C and room temperature. This study showed that the storage conditions affected viable bacteria and bacterial DNA and that freezing and drying were significant for their long-term storage. We provide important information for the storage of microbial forensic specimens.

  20. Assessing the blood pressure waveform of the carotid artery using an ultrasound image processing method

    Energy Technology Data Exchange (ETDEWEB)

    Soleimani, Effat; Mokhtari-Dizaji, Manijhe [Dept. of Medical Physics, Tarbiat Modares University, Tehran (Iran, Islamic Republic of); Fatouraee, Nasser [Dept. of Medical Engineering, Amirkabir University of Technology, Tehran (Iran, Islamic Republic of); Saben, Hazhir [Dept. Radiology, Imaging Center of Imam Khomaini Hospital, Tehran Medical Sciences University, Tehran (Iran, Islamic Republic of)

    2017-04-15

    The aim of this study was to introduce and implement a noninvasive method to derive the carotid artery pressure waveform directly by processing diagnostic sonograms of the carotid artery. Ultrasound image sequences of 20 healthy male subjects (age, 36±9 years) were recorded during three cardiac cycles. The internal diameter and blood velocity waveforms were extracted from consecutive sonograms over the cardiac cycles by using custom analysis programs written in MATLAB. Finally, the application of a mathematical equation resulted in time changes of the arterial pressure. The resulting pressures were calibrated using the mean and the diastolic pressure of the radial artery. A good correlation was found between the mean carotid blood pressure obtained from the ultrasound image processing and the mean radial blood pressure obtained using a standard digital sphygmomanometer (R=0.91). The mean absolute difference between the carotid calibrated pulse pressures and those measured clinically was -1.333±6.548 mm Hg. The results of this study suggest that consecutive sonograms of the carotid artery can be used for estimating a blood pressure waveform. We believe that our results promote a noninvasive technique for clinical applications that overcomes the reproducibility problems of common carotid artery tonometry with technical and anatomical causes.

  1. The Assessment of Cytotoxicity and Genotoxicity of Mirtazapine in Human Blood Lymphocytes Using Micronucleus Test

    Directory of Open Access Journals (Sweden)

    M Norizadeh tazehkand

    2015-02-01

    Results: MN formation was not significantly induced at 24- and 48-h treatment periods when compared with control but Nuclear division index (NDI significantly decreased at all concentrations for two treatment periods. Conclusion: Mirtazapine was not genetoxic but was cytotoxic in human peripheral blood lymphocytes. According to this study mirtazapine has cytotoxic effects on human's cells.

  2. Longitudinal assessment of blood-brain barrier leakage during epileptogenesis in rats. A quantitative MRI study.

    NARCIS (Netherlands)

    van Vliet, E.A.; Otte, W.M.; Gorter, J.A.; Dijkhuizen, R.M.; Wadman, W.J.

    2014-01-01

    The blood-brain barrier (BBB) plays an important role in the homeostasis of the brain. BBB dysfunction has been implicated in the pathophysiology of various neurological disorders, including epilepsy in which it may contribute to disease progression. Precise understanding of BBB dynamics during epil

  3. Short communication: Assessing urea transport from milk to blood in dairy cows

    NARCIS (Netherlands)

    Spek, J.W.; Dijkstra, J.; Borne, van den J.J.G.C.; Bannink, A.

    2012-01-01

    The concentration of urea in milk (MUC) has emerged as a potentially useful tool to predict urinary N excretion. Various factors may affect the relationship between MUC and urinary N excretion, including transport characteristics of urea from blood to milk and vice versa. The main objective of this

  4. Assessment of erythrocyte aggregation in whole blood samples by light backscattering: clinical applications

    Science.gov (United States)

    Priezzhev, Alexander V.; Firsov, Nikolai N.; Vyshlova, Marina G.; Lademann, Juergen; Richter, Heike; Kiesewetter, Holger; Mueller, Gerhard J.

    1999-05-01

    We report on the results of a collaborative effort made in the field of optical diagnostics of whole blood samples to study the ability of red blood cells to aggregate in a Couette chamber. We studied a possibility to quantitatively measure this ability as a function of the physiological state of blood donors. The aggregometer designed by the Russian coauthors of this paper and described in their earlier publications (see e.g. Proc SPIE 1884, 2100, 2678, 2982) was extensively used in the experiments performed in the Rheumatology Institute in Moscow and in the Charite Clinic in Berlin. The following parameters were measured: two characteristic times of RBC aggregation and the average spontaneous aggregation rate in the state of stasis, the average hydrodynamic strength of all aggregates and that of the largest aggregates. Different algorithms of the remission signal processing for the quantitative evaluation of the above parameters were compared. Reproducible alterations of the parameters from their normal values were obtained for blood samples from individuals suffering auto-immune disease and diabetes. Statistical data is reported proving high efficiency of the technique for the diagnostics of rheological disorders. Basing on these data the quantitative criteria of the heaviness of hemorheological state of the patients are proposed that are important for choosing specific therapies for which the patient is minimally resistant.

  5. Retinal hemodynamic oxygen reactivity assessed by perfusion velocity, blood oximetry and vessel diameter measurements

    DEFF Research Database (Denmark)

    Klefter, Oliver Niels; Lauritsen, Anne Øberg; Larsen, Michael

    2015-01-01

    PURPOSE: To test the oxygen reactivity of a fundus photographic method of measuring macular perfusion velocity and to integrate macular perfusion velocities with measurements of retinal vessel diameters and blood oxygen saturation. METHODS: Sixteen eyes in 16 healthy volunteers were studied at two...... measurements may provide comprehensive information about retinal metabolism....

  6. Scalp blood lactate for intra-partum assessment of fetal metabolic acidosis

    NARCIS (Netherlands)

    Heinis, A.M.; Spaanderman, M.E.A.; Gunnewiek, J.M.; Lotgering, F.K.

    2011-01-01

    Objective. To study to what extent the fetal scalp blood lactate concentration during labor correlates with fetal scalp pH and base deficit, and metabolic acidosis at birth, and to suggest lactate cut-off values to serve as indicators for either reassurance or immediate intervention. Design. A retro

  7. A comparative assessment of nursing students' cognitive knowledge of blood transfusion using lecture and simulation.

    Science.gov (United States)

    Flood, Lisa S; Higbie, Julie

    2016-01-01

    Professional nurses must have the knowledge and skills to safely administer blood products and monitor for life-threatening complications. Nurse educators should ensure that student nurses also learn how to safely administer blood products; however students rarely have the opportunity to witness and manage adverse transfusion reactions. Despite the low incidence of rare adverse transfusion reactions, nursing students must be able to immediately recognize transfusion reactions, implement appropriate interventions, and communicate effectively with health care providers. To reinforce blood transfusion knowledge, practice technical skills, and promote management of adverse reactions, a human patient simulation experience was created for baccalaureate nursing students to provide application of related classroom content. Using a quasi-experimental design, students who received a related didactic lecture preceding the simulation were compared with students who did not receive the lecture. The lecture group's pre/posttest mean scores (n = 42) were significantly higher than the no lecture group's mean scores (n = 44). This simulation design included proper blood administration procedures, patient monitoring, management of transfusion reactions, and practice with interdisciplinary communication. Participation in a human patient simulation following a related didactic lecture may be useful to strengthen cognitive learning and help bridge the didactic-clinic gap.

  8. The Influence of Low Platelet Count on Whole Blood Aggregometry Assessed by Multiplate

    DEFF Research Database (Denmark)

    Stissing, Trine; Dridi, Nadia P; Ostrowski, Sisse R

    2011-01-01

    in an artificial matrix, platelet-rich plasma (PRP). Heparinized and citrated blood was diluted with autologous plasma to platelet concentrations 200 to 25 × 10(9)/L in WB samples (n = 10) and 200 to 100 × 10(9)/L in PRP samples (n = 7). The platelet aggregation was investigated by the ADP-, ASPI-, COL-, and TRAP...

  9. Dynamic Perfusion CT Assessment of the Blood-Brain Barrier Permeability : First Pass versus Delayed Acquisition

    NARCIS (Netherlands)

    Dankbaar, J. W.; Hom, J.; Schneider, T.; Cheng, S. -C.; Lau, B. C.; van der Schaaf, I.; Virmani, S.; Pohlman, S.; Dillon, W. P.; Wintermark, M.

    2008-01-01

    BACKGROUND AND PURPOSE: The Patlak model has been applied to first-pass perfusion CT (PCT) data to extract information on blood-brain barrier permeability (BBBP) to predict hemorrhagic transformation in patients with acute stroke. However, the Patlak model was originally described for the delayed st

  10. Liver function in Huntington's disease assessed by blood biochemical analyses in a clinical setting

    DEFF Research Database (Denmark)

    Nielsen, Signe Marie Borch; Vinther-Jensen, Tua; Nielsen, Jørgen E.

    2016-01-01

    , the manifest HD gene-expansion carriers displayed moderate increases in total cholesterol and blood glucose relative to the premanifest HD gene-expansion carriers, as well as increased C-reactive protein relative to HD gene-expansion negative controls. Our results show that LFT values are elevated more...

  11. Whole blood viscosity assessment issues IV: Prevalence in acute phase inflammation

    Directory of Open Access Journals (Sweden)

    Ezekiel Uba Nwose

    2010-08-01

    Full Text Available Background: Hyperviscosity syndrome has been suggested as not simply an acute reaction. Yet, erythrocyte sedimentation rate is associated with whole blood viscosity and it is an indirect acute phase inflammation marker. Aims: This work investigates the prevalence of hyperviscosity in acute phase inflammation. Materials and Methods: Archived clinical pathology data for the period of 1999 to 2008 were utilized. 40,632-cases tested for C-reactive protein and/or erythrocyte sedimentation rate from five alternate years, which were concomitantly tested for haematocrit and total proteins, were extracted. The prevalence of abnormal viscosity associated with positive results of C-reactive protein and erythrocyte sedimentation rate were evaluated. Results: Hyperviscosity is infrequently associated with positive C-reactive protein (2.9% and erythrocyte sedimentation rate (2.7% sub-populations, and are not statistically different from their respective negative sub-populations. Normoviscosity is significantly more prevalent in the positive sub-populations (p < 0.01. Further analyses indicate that prevalence of acute phase inflammation is statistically significantly less in hyperviscosity compared to normoviscosity sub-population (p < 0.00001. Actual blood viscosity level increases with level of inflammation though. Conclusion: The study demonstrates that although blood viscosity level may increase with inflammation, hyperviscosity is not frequent in, or sensitive to acute phase inflammation. It portends that whole blood viscosity is not unspecific as acute phase inflammation markers. It calls for clinicians to consider utilizing whole blood viscosity in disease conditions where stasis is implicated, in which it is specific and valuable. It would also benefit to establish whether hyperviscosity is a chronic phase inflammation marker.

  12. Assessing the Effect of Simultaneous Exposure to Noise and Cigarette Smoke on Workers’ Blood Pressure

    Science.gov (United States)

    Rahimpour, Farzane; Rafiei Manesh, Ehsan; Jarahi, Lida; Eghbali, Saba

    2016-01-01

    Introduction: Noise, as the most common pollutant in the industrial environment, can lead to hearing loss and negatively affect other organs such as the cardiovascular system. Cigarette smoking is a popular habit among some workers, and can also have a negative effect on the cardiovascular system. This study was aimed to investigate the effect of simultaneous exposure to noise and cigarette smoke on the blood pressure of workers at a manufacturing factory. Materials and Methods: This cross-sectional study enrolled 604 workers at a steel factory. Information relating to workers’ demography, employment, and risk factors were recorded. Based on the level of smoking per day, workers exposed to noise fell into one of the four following groups: 1) Non-smokers exposed to noise <85 DB; 2) Smokers exposed to noise <85 DB; 3) Non-smokers exposed to noise ≥85 DB; 4) Smokers exposed to noise ≥85 DB. A t-test, analysis of variance (ANOVA), and logistic regression were applied for analysis using SPSS v11.5. Results: The prevalence of hypertension, cigarette smoking, and exposure to noise ≥85 DB was 11.6%, 15.3%, and 56.4%, respectively, among the workers. The mean systolic blood pressure (SBP) and diastolic blood pressure (DBP) were 112.3 and 73.9 mmHg, respectively. A significant difference was observed between systolic and diastolic blood pressures in four groups (P=0.001). Posthoc test showed a significant difference between groups 1 and 3 (P=0.001). Regression analysis indicated no significant difference in workers who were simultaneously exposed to noise and cigarette smoke. Conclusion: This study demonstrates that noise is an important factor in terms of hypertension, with no significant differences observed in the prevalence of hypertension between workers who were simultaneously exposed to noise and cigarette smoke. It is suggested that workers’ blood pressure should be regularly monitored in noisy environments. PMID:28008392

  13. Assessment of blood donation intention among medical students in Pakistan--An application of theory of planned behavior.

    Science.gov (United States)

    Faqah, Anadil; Moiz, Bushra; Shahid, Fatima; Ibrahim, Mariam; Raheem, Ahmed

    2015-12-01

    Theory of Planned Behavior proposes a model which can measure how human actions are guided. It has been successfully utilized in the context of blood donation. We employed a decision-making framework to determine the intention of blood donation among medical students who have never donated blood before the study. Survey responses were collected from 391 medical students from four various universities on a defined questionnaire. The tool composed of 20 questions that were formulated to explain donation intention based on theory of planned behavior. The construct included questions related to attitude, subjective norm and perceived behavior control, descriptive norm, moral norm, anticipated regret, donation anxiety and religious norm. Pearson's correlational relationships were measured between independent and dependent variables of intention to donate blood. ANOVA was applied to observe the model fit; a value of 0.000 was considered statistically significant. A multiple regression analysis was conducted to explore the relative importance of the main independent variables in the prediction of intention. Multi-collinearity was also evaluated to determine that various independent variables determine the intention. The reliability of measures composed of two items was assessed using inter-item correlations. Three hundred and ninety-one medical students (M:F; 1:2.2) with mean age of 21.96 years ± 1.95 participated in this study. Mean item score was 3.8 ± 0.83. Multiple regression analysis suggested that perceived behavioral control, anticipated regret and attitude were the most influential factors in determining intention of blood donation. Donation anxiety was least correlated and in fact bore a negative correlation with intention. ANOVA computed an F value of 199.082 with a p-value of 0.000 indicating fitness of model. The value of R square and adjusted R square was 0.811 and 0.807 respectively indicating strong correlation between various independent and dependent

  14. Comparative proteomics evaluation of plasma exosome isolation techniques and assessment of the stability of exosomes in normal human blood plasma.

    Science.gov (United States)

    Kalra, Hina; Adda, Christopher G; Liem, Michael; Ang, Ching-Seng; Mechler, Adam; Simpson, Richard J; Hulett, Mark D; Mathivanan, Suresh

    2013-11-01

    Exosomes are nanovesicles released by a variety of cells and are detected in body fluids including blood. Recent studies have highlighted the critical application of exosomes as personalized targeted drug delivery vehicles and as reservoirs of disease biomarkers. While these research applications have created significant interest and can be translated into practice, the stability of exosomes needs to be assessed and exosome isolation protocols from blood plasma need to be optimized. To optimize methods to isolate exosomes from blood plasma, we performed a comparative evaluation of three exosome isolation techniques (differential centrifugation coupled with ultracentrifugation, epithelial cell adhesion molecule immunoaffinity pull-down, and OptiPrep(TM) density gradient separation) using normal human plasma. Based on MS, Western blotting and microscopy results, we found that the OptiPrep(TM) density gradient method was superior in isolating pure exosomal populations, devoid of highly abundant plasma proteins. In addition, we assessed the stability of exosomes in plasma over 90 days under various storage conditions. Western blotting analysis using the exosomal marker, TSG101, revealed that exosomes are stable for 90 days. Interestingly, in the context of cellular uptake, the isolated exosomes were able to fuse with target cells revealing that they were indeed biologically active.

  15. Biocompatibility studies of silk fibroin-based artificial nerve grafts in vitro and in vivo

    Institute of Scientific and Technical Information of China (English)

    2007-01-01

    Silk fibroin (SF) has been used extensively in the biomedical field including tissue engineering for the generation of artificial bones, skins or ligaments. We have previously reported on good in vitro biocompatibility of SF fibers with peripheral nerve tissues and cells. In the present study, we developed a novel design of the SF-based artificial nerve graft (SF graft) which was composed of a SF-nerve guidance conduit (NGC) inserted with SF fibers. MTT assay was performed to determine the cytotoxicity of the SF-NGC extract fluid on the cultured L929 cells derived from an immortalized mouse fibroblast cell line. In addition, this SF graft was implanted into adult rats for bridging a 10-mm long sciatic nerve defect. The following-up experiments at initial stage (1-4 week) of nerve regeneration including routine blood tests and histochemical investigation were conducted to evaluate the in vivo biocompatibility of the SF graft with peripheral nerves. The results demonstrated that the SF-NGC graft was biocompatible with the surrounding tissues and cells due to its low inflammatory potential with a grade O under the U. S. Pharmacopeia guidelines and it was generally suitable to a certain degree for bridging peripheral nerve defects in virtue of supporting Schwann cell adherence, expansion and migration. Therefore the SF graft is a promising alternative to classical autografts for peripheral nerve repair.

  16. Functional biocompatibility testing of silicone breast implants and a novel classification system based on surface roughness.

    Science.gov (United States)

    Barr, S; Hill, E W; Bayat, A

    2017-06-27

    Increasing numbers of women undergo breast implantation for cosmetic and reconstructive purposes. Contracture of the fibrous capsule, which encases the implant leads to significant pain and reoperation. Texture, wettability and the cellular reaction to implant surfaces are poorly understood determinants of implant biocompatibility. The aim of this study was to evaluate the in-vitro characteristics of a range of commercial available implants using a macrophage based assay of implant biocompatibility and a quantitative assessment of wettability and texture. Thirteen commercially available surfaces were subjected to wettability and texture characterisation using scanning and laser confocal microscopy. THP-1 macrophages were cultured on their surfaces and assessed using Integrin αV immunocytochemistry, SEM and RT-PCR for the expression of TNF-Alpha, IL-6, IL-10 and a cytokine array for the production of TNF-alpha, IL-10, IL-1RA and IL1β; important indicators of inflammation and macrophage polarization. Textured surfaces can be accurately sub-categorized dependent upon roughness and re-entrant features into four main types (macro, micro, meso and nano-textured surfaces). Significant (P based on roughness and present a macrophage based assay of breast implant biocompatibility with a quantitative assessment of implant wettability and texture. The breast implant surface-cell interaction is variable and sufficient to alter healing response and capsular contracture fate in-vivo. Copyright © 2017 The Authors. Published by Elsevier Ltd.. All rights reserved.

  17. Zirconium phosphate nanoplatelets: a biocompatible nanomaterial for drug delivery to cancer

    Science.gov (United States)

    Saxena, Vipin; Diaz, Agustin; Clearfield, Abraham; Batteas, James D.; Hussain, Muhammad Delwar

    2013-02-01

    The objective of this study was to evaluate the biocompatibility of zirconium phosphate (ZrP) nanoplatelets (NPs), and their use in drug delivery. ZrP and doxorubicin-intercalated ZrP (DOX:ZrP) NPs were characterized by using X-Ray Powder Diffraction (XRPD), Thermogravimetric Analysis (TGA), Transmission Electron Micrography (TEM), Scanning Electron Microscopy (SEM) and Atomic Force Microscopy (AFM). Biocompatibility of ZrP NPs was evaluated in human embryonic kidney (HEK-293), breast cancer (MCF-7), metastatic breast cancer (MDA-MB-231), ovarian cancer (OVCAR-3), resistant cancer (NCI-RES/ADR) cells and mouse macrophage (RAW 264.7) cell lines. Hemocompatibility of ZrP NPs was evaluated with human red blood cells. Simulated body fluid (SBF) of pH 7.4 was used to determine the in vitro release of doxorubicin from DOX:ZrP NPs. Cellular uptake and in vitro cytotoxicity studies of DOX:ZrP NPs were determined in MDA-MB-231. The ZrP nanomaterial can be prepared in the 100-200 nm size range with a platelet-like shape. The ZrP NPs themselves are biocompatible, hemocompatible and showed no toxicity to the macrophage cells. ZrP NPs can intercalate high loads (35% w/w) of doxorubicin between their layers. The release of DOX was sustained for about 2 weeks. DOX:ZrP NPs showed higher cellular uptake and increased cytotoxicity than free DOX in MDA-MB-231 cells. ZrP NPs are highly biocompatible, can intercalate large amounts of drugs and sustain the release of drugs. ZrP NPs improved the cellular uptake and cytotoxicity of DOX to MDA-MB-231 cells. ZrP NPs are promising nanocarriers for drug delivery in cancer therapy.The objective of this study was to evaluate the biocompatibility of zirconium phosphate (ZrP) nanoplatelets (NPs), and their use in drug delivery. ZrP and doxorubicin-intercalated ZrP (DOX:ZrP) NPs were characterized by using X-Ray Powder Diffraction (XRPD), Thermogravimetric Analysis (TGA), Transmission Electron Micrography (TEM), Scanning Electron Microscopy (SEM

  18. Assessing peripheral blood cell profile of Yorkshire pigs divergently selected for residual feed intake.

    Science.gov (United States)

    Mpetile, Z; Young, J M; Gabler, N K; Dekkers, J C M; Tuggle, C K

    2015-03-01

    The cost of feed is a serious issue in the pork industry, contributing about 65 to 75% of the total production cost. To prevent economic losses and decreased productivity of the herd, it is important to select for animals that eat less for the same lean gain, or more efficient animals. Residual feed intake (RFI) is the difference between observed feed intake and expected feed intake based on estimated maintenance and production requirements. Selection for decreased RFI, or more efficient animals, is a potential solution to higher feed costs in pig production. However, animals that are highly selected for decreased RFI may have reduced energy input to the immune system and fail to withstand diseases and stressors after infection that negatively impact profitability. The objective of this study was to evaluate differences in circulating blood cell profiles at a young age between 2 lines of Yorkshire pigs that were divergently selected for RFI as well as the heritability of these traits, to investigate effects of selection for RFI on immune system parameters, and to identify potential biomarkers for feed efficiency. Previous work has shown that the 2 lines had diverged for IGF-1 in serum in young pigs and, therefore, this stage was investigated for other potential physiological differences. Blood samples were drawn for a complete blood count (CBC) analysis from 517 gilts and barrows, ages 35 to 42 d, across the 2 lines. In general, the low-RFI line had lower numbers of specific types of white blood cells but higher hemoglobin concentration and red blood cell volume compared to the high-RFI line. No significant correlations were found between CBC traits and RFI across and within the lines (0.05 < < 0.1). Of the 15 CBC traits that were measured, 3 were highly heritable (0.56 < < 0.62), 9 were moderately heritable (0.12 < < 0.47), and 3 were lowly heritable ( < 0.12), suggesting a substantial genetic component for CBC traits and that selection for CBC traits could be

  19. Integrative assessment of kick boxers’ brain blood circulation and bio-electrical activity in conditions of correction technologies’ application

    Directory of Open Access Journals (Sweden)

    Romanov Y.N.

    2016-06-01

    Full Text Available Purpose: to scientifically substantiate the role of para-vertebral impacts on blood circulation and bio-electrical activity of kick boxers’ cortex. Material: in the research participated kick boxers (main group, n=62 and university students (control group, n=25 of 18-23 years’ age. Assessment of para-vertebral impacts with device Armos and classic massage was fulfilled with the help of the following methodic: trans-cranial dopplerography of head main arteries and cortex EEG of the tested. Results: it was found that with the help of para-vertebral impacts by device Armos linear velocity of cerebral blood flow reduces to normal limits and in- and inter-hemispheres’ interaction strength increases. Conclusions: para-vertebral impacts by device Armos activate integrative processes and inter-hemispheres’ interactions of different cortex areas of kick boxers. It can witness about better formation of functional systems, ensuring sports efficiency.

  20. Development of screening assays for nanoparticle toxicity assessment in human blood: preliminary studies with charged Au nanoparticles.

    Science.gov (United States)

    Love, Sara A; Thompson, John W; Haynes, Christy L

    2012-09-01

    As nanoparticles have found increased use in both consumer and medical applications, corresponding increases in possible exposure to humans necessitate studies examining the impacts of these nanomaterials in biological systems. This article examines the effects of approximately 30-nm-diameter gold nanoparticles, with positively and negatively charged surface coatings in human blood. Here, we study the exposure effects, with up to 72 h of exposure to 5, 15, 25 and 50 µg/ml nanoparticles on hemolysis, reactive oxygen species (ROS) generation and platelet aggregation in subsets of cells from human blood. Assessing viability with hemolysis, results show significant changes in a concentration-dependent fashion. Rates of ROS generation were investigated using the dichlorofluorscein diacetate-based assay as ROS generation is a commonly suspected mechanism of nanoparticle toxicity; herein, ROS was not a significant factor. Optical monitoring of platelet aggregation revealed that none of the examined nanoparticles induced aggregation upon short-term exposure.

  1. Regional myocardial blood flow, metabolism and function assessed noninvasively by positron emission tomography

    Energy Technology Data Exchange (ETDEWEB)

    Schelbert, H.R.; Phelps, M.E.; Hoffman, E.; Huang, S.; Kuhl, D.E.

    1979-01-01

    Positron emission computed tomography is a new technique for the noninvasive measure of myocardial blood flow, mechanical function and, in particular, metabolism. The capability of this new study means is due to the technological innovations of the imaging device and the availability of radioactive tracers that are specific for blood flow and metabolism. The device permits recording of cross-sectional images of the left ventricular myocardium that reflect quantitatively regional tracer tissue concentrations. By employing tracer kinetic models this new technique permits the measurement of regional glucose and fatty acid metabolism of the heart. While already an important new tool for investigative studies into cardiac physiology and pathophysiology, the clinical utility of positron emission tomography remains to be defined.

  2. Metabolic targets of endocrine disrupting chemicals assessed by cord blood transcriptome profiling

    DEFF Research Database (Denmark)

    Remy, Sylvie; Govarts, Eva; Wens, Britt

    2016-01-01

    Early life exposure to endocrine disrupting chemicals (EDCs) has been frequently associated with impaired perinatal growth, an important risk factor for later onset of metabolic disorders. We analyzed whether the cord blood transcriptome showed early indications of alterations in metabolic......’ pathways were significantly enriched in relation to p,p′-DDE. Transcriptional changes at birth suggest a role for specific metabolic targets as a link between prenatal EDC exposure and metabolic disorders later in life. © 2016 Elsevier Inc....

  3. [Cord blood procalcitonin in the assessment of early-onset neonatal sepsis].

    Science.gov (United States)

    Oria de Rueda Salguero, Olivia; Beceiro Mosquera, José; Barrionuevo González, Marta; Ripalda Crespo, María Jesús; Olivas López de Soria, Cristina

    2017-08-01

    Early diagnosis of early-onset neonatal sepsis (EONS) is essential to reduce morbidity and mortality. Procalcitonin (PCT) in cord blood could provide a diagnosis of infected patients from birth. To study the usefulness and safety of a procedure for the evaluation of newborns at risk of EONS, based on the determination of PCT in cord blood. Neonates with infectious risk factors, born in our hospital from October 2013 to January 2015 were included. They were processed according to an algorithm based on the values of cord blood procalcitonin (< 0.6ng/ml versus ≥0.6ng/ml). They were later classified as proved infection, probable, or no infection. Of the 2,519 infants born in the study period, 136 met inclusion criteria. None of 120 cases with PCT<0.6ng/ml in cord blood developed EONS (100% negative predictive value). On the other hand, of the 16 cases with PCT ≥0.6ng/ml, 10 were proven or probably infected (62.5% positive predictive value). The sensitivity of the PCT against infection was 100%, with a specificity of 95.2% (area under the receiver operator curve 0.969). The incidence of infection in the study group was 7.4%, and 26.1% in cases with maternal chorioamnionitis. 21 newborn (15.4%) received antibiotic therapy. The studied protocol has shown to be effective and safe to differentiate between patients with increased risk of developing an EONS, in those where the diagnostic and therapeutic approach was more interventionist, versus those with less likelihood of sepsis, who would benefit from a more conservative management. Copyright © 2016 Asociación Española de Pediatría. Publicado por Elsevier España, S.L.U. All rights reserved.

  4. Fast and Specific Assessment of the Halogenating Peroxidase Activity in Leukocyte-enriched Blood Samples.

    Science.gov (United States)

    Flemmig, Jörg; Schwarz, Pauline; Bäcker, Ingo; Leichsenring, Anna; Lange, Franziska; Arnhold, Jürgen

    2016-07-28

    In this paper a protocol for the quick and standardized enrichment of leukocytes from small whole blood samples is described. This procedure is based on the hypotonic lysis of erythrocytes and can be applied to human samples as well as to blood of non-human origin. The small initial sample volume of about 50 to 100 µl makes this method applicable to recurrent blood sampling from small laboratory animals. Moreover, leukocyte enrichment is achieved within minutes and with low material efforts regarding chemicals and instrumentation, making this method applicable in multiple laboratory environments. Standardized purification of leukocytes is combined with a highly selective staining method to evaluate halogenating peroxidase activity of the heme peroxidases, myeloperoxidase (MPO) and eosinophil peroxidase (EPO), i.e., the formation of hypochlorous and hypobromous acid (HOCl and HOBr). While MPO is strongly expressed in neutrophils, the most abundant immune cell type in human blood as well as in monocytes, the related enzyme EPO is exclusively expressed in eosinophils. The halogenating activity of these enzymes is addressed by using the almost HOCl- and HOBr-specific dye aminophenyl fluorescein (APF) and the primary peroxidase substrate hydrogen peroxide. Upon subsequent flow cytometry analysis all peroxidase-positive cells (neutrophils, monocytes, eosinophils) are distinguishable and their halogenating peroxidase activity can be quantified. Since APF staining may be combined with the application of cell surface markers, this protocol can be extended to specifically address leukocyte sub-fractions. The method is applicable to detect HOCl and HOBr production both in human and in rodent leukocytes. Given the widely and diversely discussed immunological role of these enzymatic products in chronic inflammatory diseases, this protocol may contribute to a better understanding of the immunological relevance of leukocyte-derived heme peroxidases.

  5. In vivo fast equilibrium microextraction by stable and biocompatible nanofiber membrane sandwiched in microfluidic device.

    Science.gov (United States)

    Wu, Qian; Wu, Dapeng; Guan, Yafeng

    2013-12-03

    In vivo analysis poses higher requirements about the biocompatibility, selectivity and speed of analytical method. In this study, an in vivo fast equilibrium microextraction method was developed with a biocompatible core-sheath electrospun nanofiber membrane sandwiched within a microfluidic unit. The polystyrene/collagen core-sheath nanofiber membrane was coaxially electrospun and strengthened with in situ glutaraldehyde cross-linking. This membrane not only kept high mass transfer rate, large extraction capacity and biomatrix resistance as our previously proposed membrane (Anal. Chem. 2013, 85 (12), 5924-5932), but also got much better mechanical strength and stability in water. The microfluidic device was designed to sandwich the membrane, and the blood in vivo can be introduced into it and get contact with the membrane repetitively. With this membrane and device, a 2-min equilibrium in vivo extraction method was established, validated in a simulated blood circulation system, and was used to monitor the pharmacokinetic profiles of desipramine in rabbits. The free and total concentration of desipramine in vivo was monitored with 10-min interval almost without rabbit blood consumed. The results met well with those of in vitro extraction, and a correlation factor of 0.99 was obtained.

  6. Overview of Stabilizing Ligands for Biocompatible Quantum Dot Nanocrystals

    Directory of Open Access Journals (Sweden)

    Aaron Clapp

    2011-11-01

    Full Text Available Luminescent colloidal quantum dots (QDs possess numerous advantages as fluorophores in biological applications. However, a principal challenge is how to retain the desirable optical properties of quantum dots in aqueous media while maintaining biocompatibility. Because QD photophysical properties are directly related to surface states, it is critical to control the surface chemistry that renders QDs biocompatible while maintaining electronic passivation. For more than a decade, investigators have used diverse strategies for altering the QD surface. This review summarizes the most successful approaches for preparing biocompatible QDs using various chemical ligands.

  7. FABRICATION AND BIOCOMPATIBILITY OF CELL OUTER MEMBRANE MIMETIC SURFACES

    Institute of Scientific and Technical Information of China (English)

    Ming-ming Zong; Yong-kuan Gong

    2011-01-01

    The surface design used for improving biocompatibility is one of the most important issues for the fabrication of medical devices. For mimicking the ideal surface structure of cell outer membrane, a large number of polymers bearing phosphorylcholine (PC) groups have been employed to modify the surfaces of biomaterials and medical devices. It has been demonstrated that the biocompatibility of the modified materials whose surface is required to interact with a living organism has been obviously improved by introducing PC groups. In this review, the fabrication strategies of cell outer membrane mimetic surfaces and their resulted biocompatibilities were summarized.

  8. Investigation into Effects of Scanning Speed on in Vitro Biocompatibility of Selective Laser Melted 316L Stainless Steel Parts

    Directory of Open Access Journals (Sweden)

    Shang Yitong

    2017-01-01

    Full Text Available In recent years, selective laser melting (SLM has gained an important place in fabrication due to their strong individualization which cannot be manufactured using conventional processes such as casting or forging. By proper control of the SLM processing parameters, characteristics of the alloy can be optimized. In the present work, 316L stainless steel (SS, as a widely used biomedical material, is investigated in terms of the effects of scanning speed on in vitro biocompatibility during SLM process. Cytotoxicity assay is adopted to assess the in vitro biocompatibility. The results show the scanning speed strongly affects the in vitro biocompatibility of 316L SS parts and with prolongs of incubation time, the cytotoxicity increase and the in vitro biocompatibility gets worse. The optimal parameters are determined as follows: scanning speed of 900 mm/s, laser power of 195 W, hatch spacing of 0.09 mm and layer thickness of 0.02 mm. The processing parameters lead to the change of surface morphology and microstructures of samples, which can affect the amount of toxic ions release, such as Cr, Mo and Co, that can increase risks to patient health and reduce the biocompatibility.

  9. Material Biocompatibility for PCR Microfluidic Chips

    KAUST Repository

    Kodzius, Rimantas

    2010-04-23

    As part of the current miniaturization trend, biological reactions and processes are being adapted to microfluidics devices. PCR is the primary method employed in DNA amplification, its miniaturization is central to efforts to develop portable devices for diagnostics and testing purposes. A problem is the PCR-inhibitory effect due to interaction between PCR reagents and the surrounding environment, which effect is increased in high-surface-are-to-volume ration microfluidics. In this study, we evaluated the biocompatibility of various common materials employed in the fabrication of microfluidic chips, including silicon, several kinds of silicon oxide, glasses, plastics, wax, and adhesives. Two-temperature PCR was performed with these materials to determine their PCR-inhibitory effect. In most of the cases, addition of bovine serum albumin effectively improved the reaction yield. We also studied the individual PCR components from the standpoint of adsorption. Most of the materials did not inhibit the DNA, whereas they did show noticeable interaction with the DNA polymerase. Our test, instead of using microfluidic devices, can be easily conducted in common PCR tubes using a standard bench thermocycler. Our data supports an overview of the means by which the materials most bio-friendly to microfluidics can be selected.

  10. Microfresado de polímeros biocompatibles

    Directory of Open Access Journals (Sweden)

    Yenny Marcela Orozco O.

    2012-01-01

    Full Text Available En este artículo se presentan resultados de una investigación llevada a cabo en micromecanizado de polímeros biocompatibles. Se describen los procesos de fabricación de micropartes con el fin de mostrar los niveles de precisión y escalas dimensionales alcanzables con un centro de micromecanizado Kern Evo. Adicionalmente, se muestran los resultados de una serie de pruebas de microcorte realizadas con fresas de tungsteno de 100 um de diámetro sobre probetas de PMMA (Polimetilmetacrilato, grado médico para determinar los parámetros que minimizan el tamaño de las rebabas generadas. Para caracterizar tanto superficies generadas, como condiciones iniciales y finales de las herramientas se emplearon técnicas de microscopía óptica y electrónica. Los resultados referentes a las primeras pruebas de mecanizado indican que en el control de las características dimensionales se deben vigilar aspectos como la profundidad de corte establecida, el método de sujeción seleccionado y la tolerancia de alineación de la pieza; incluso deben controlarse las condiciones ambientales del recinto donde opera el equipo.

  11. Fabrication and Biocompatibility of Electrospun Silk Biocomposites

    Science.gov (United States)

    Wei, Kai; Kim, Byoung-Suhk; Kim, Ick-Soo

    2011-01-01

    Silk fibroin has attracted great interest in tissue engineering because of its outstanding biocompatibility, biodegradability and minimal inflammatory reaction. In this study, two kinds of biocomposites based on regenerated silk fibroin are fabricated by electrospinning and post-treatment processes, respectively. Firstly, regenerated silk fibroin/tetramethoxysilane (TMOS) hybrid nanofibers with high hydrophilicity are prepared, which is superior for fibroblast attachment. The electrospinning process causes adjacent fibers to ‘weld’ at contact points, which can be proved by scanning electron microscope (SEM). The water contact angle of silk/tetramethoxysilane (TMOS) composites shows a sharper decrease than pure regenerated silk fibroin nanofiber, which has a great effect on the early stage of cell attachment behavior. Secondly, a novel tissue engineering scaffold material based on electrospun silk fibroin/nano-hydroxyapatite (nHA) biocomposites is prepared by means of an effective calcium and phosphate (Ca–P) alternate soaking method. nHA is successfully produced on regenerated silk fibroin nanofiber within several min without any pre-treatments. The osteoblastic activities of this novel nanofibrous biocomposites are also investigated by employing osteoblastic-like MC3T3-E1 cell line. The cell functionality such as alkaline phosphatase (ALP) activity is ameliorated on mineralized silk nanofibers. All these results indicate that this silk/nHA biocomposite scaffold material may be a promising biomaterial for bone tissue engineering. PMID:24957869

  12. ADHESION OF BIOCOMPATIBLE TiNb COATING

    Directory of Open Access Journals (Sweden)

    Tomas Kolegar

    2017-06-01

    Full Text Available Preparation of a coating with a high quality requires good adhesion of the film to the substrate. The paper deals with the adhesion of biocompatible TiNb coating with different base materials. Several materials such as titanium CP grade 2, titanium alloys Ti6Al4V and stainless steel AISI 316L were measured. Testing samples were made in the shape of small discs. Those samples were coated with a TiNb layer by using the PVD method (magnetron sputtering. Onto the measured layer of TiNb an assistant cylinder was stuck using a high strength epoxy adhesive E1100S. The sample with the assistant cylinder was fixed into a special fixture and the whole assembly underwent pull-off testing for adhesion. The main result of this experiment was determining the strength needed to peel the layer and morphology and size of the breakaway. As a result, we will be able to determine the best base material and conditions where the coating will be remain intact with the base material.

  13. Effect of biologically active coating on biocompatibility of Nitinol devices designed for the closure of intra-atrial communications

    NARCIS (Netherlands)

    Kong, XQ; Grabitz, RG; van Oeveren, W; Klee, D; van Kooten, TG; Freudenthal, F; Qing, M; von Bernuth, G; Seghaye, MC

    2002-01-01

    Anti-thrombogenicity and rapid endothelialisation are prerequisites for the use of closure devices of intra-atrial communications in order to reduce the risk of cerebral embolism. The purpose of this study was therefore to assess the effect of bioactive coatings on biocompatibility of Nitinol coils

  14. Biocompatibility of microcapsules for cell immobilization elaborated with different type of alginates.

    Science.gov (United States)

    Orive, G; Ponce, S; Hernández, R M; Gascón, A R; Igartua, M; Pedraz, J L

    2002-09-01

    The biocompatibility of alginate-PLL-alginate (APA) microcapsules has been evaluated with respect to impurity levels. The impurity content of three different alginates (a raw high M-alginate, a raw high G-alginate and a purified high G-alginate) has been determined and the in vivo antigenic response of APA beads made with each alginate assessed. Results show that purification of the alginate not only reduces the total amount of impurities (63% less in polyphenols, 91.45% less in endotoxins and 68.5% less in protein in relation to raw high M-alginate), but also avoids an antibody response when microcapsules of this material are implanted in mice. In contrast, raw alginates produced a detectable antibody response though the differences in their impurity content. Consequently, this work revealed that purity of the alginate rather than their chemical composition, is probably of greater importance in determining microcapsule biocompatibility.

  15. Avaliação da biocompatibilidade de implantes mamários de silicone esterilizados por calor seco e pelo óxido de etileno Biocompatibility assessment of silicone gel breast implants sterilized by dry-heat and by ethylene oxide

    Directory of Open Access Journals (Sweden)

    Janice Campos de Azevedo

    2006-06-01

    Full Text Available Os implantes mamários de silicone têm sido empregados, tanto nas cirurgias de aumento de mama, quanto na reconstrução do tecido mamário. A segurança biológica deste tipo de implante deve ser garantida, pois, em função da esterilização estes materiais, podem sofrer alterações oriundas dos processos esterilizantes por comprometimento da estrutura química dos polímeros. O objetivo deste trabalho consistiu na avaliação da biocompatibilidade de implantes mamários preenchidos com gel de silicone, de superfície lisa e texturizada submetidos à esterilização por calor seco e óxido de etileno. Empregou-se, para tanto, método in vitro, avaliando a citotoxicidade pelo método de captura do vermelho neutro, utilizando a linhagem celular NCTC clone 929. Os resultados obtidos demonstraram não haver comprometimento da biocompatibilidade dos biomateriais submetidos aos dois processos (calor seco e óxido de etileno, assim como comprovaram a eficácia de ambos na esterilização dos implantes.Silicone breast implants have been widely used for mammary augmentation and reconstruction surgery. Biological safety of these implants can be altered by sterilization methods. This study consisted of the biocompatibility assessment of smooth and textured silicone gel breast implants sterilized by dry-heat and ethylene oxide through cell viability, employing neutral red uptake method. The NCTC clone 929 cell were employed and the results showed no cytotoxicity of implants after both sterilization processes.

  16. Effects of GSM 900 MHz on middle cerebral artery blood flow assessed by transcranial Doppler sonography.

    Science.gov (United States)

    Ghosn, Rania; Thuróczy, György; Loos, Nathalie; Brenet-Dufour, Valérie; Liabeuf, Sophie; de Seze, René; Selmaoui, Brahim

    2012-12-01

    Mobile phone use has increased worldwide but its possible effects on the brain remain unclear. The aim of the present study was to investigate the effect of acute exposure to a radio frequency electromagnetic field (RF EMF) generated by a mobile phone operating in the Global System for Mobile Communication (GSM) 900 MHz on cerebral blood flow. Twenty-nine volunteers attended two experimental sessions: a sham exposure session and a real exposure session in a cross-over double-blind study in which a mobile phone was positioned on the left side of the head. In one session, the mobile phone was operated without RF radiation (sham phone) and in the other study it was operated with RF radiation (real phone) for 20 min. Thus, each subject served as its own control. Middle cerebral artery blood flow was monitored noninvasively by transcranial Doppler sonography to measure middle cerebral artery blood flow velocity. Pulsatility index and resistance index were also evaluated. A voluntary breath holding physiological test was carried out as a positive control for testing cerebral vasoreactivity. Hemodynamic variables were recorded and analyzed before, during and after mobile phone exposure. No significant changes were detected in studied variables in middle cerebral arteries during sham or real exposure. In the exposed side the cerebral blood flow velocity, the pulsatility index and the resistance index during sham and real exposure were respectively: [61.9 ± 1.3, 61.7 ± 1.3 cm/s (P = 0.89)]; [0.93 ± 0.03, 0.90 ± 0.02 (P = 0.84)] and [0.58 ± 0.01, 0.58 ± 0.01 (P = 0.96)] at baseline; and [60.6 ± 1.3, 62 ± 1.6 cm/s (P = 0.40)]; [0.91 ± 0.03, 0.87 ± 0.03 (P = 0.97)]; [0.57 ± 0.01, 0.56 ± 0.01 (P = 0.82)] after 20 min of exposure. Twenty minutes of RF exposure to a mobile phone does not seem to affect the cerebral circulation.

  17. Vectorization of copper complexes via biocompatible and biodegradable PLGA nanoparticles.

    Science.gov (United States)

    Courant, T; Roullin, V G; Cadiou, C; Delavoie, F; Molinari, M; Andry, M C; Gafa, V; Chuburu, F

    2010-04-23

    A double emulsion-solvent diffusion approach with fully biocompatible materials was used to encapsulate copper complexes within biodegradable nanoparticles, for which the release kinetics profiles have highlighted their potential use for a prolonged circulating administration.

  18. Vectorization of copper complexes via biocompatible and biodegradable PLGA nanoparticles

    Science.gov (United States)

    Courant, T.; Roullin, V. G.; Cadiou, C.; Delavoie, F.; Molinari, M.; Andry, M. C.; Gafa, V.; Chuburu, F.

    2010-04-01

    A double emulsion-solvent diffusion approach with fully biocompatible materials was used to encapsulate copper complexes within biodegradable nanoparticles, for which the release kinetics profiles have highlighted their potential use for a prolonged circulating administration.

  19. Vectorization of copper complexes via biocompatible and biodegradable PLGA nanoparticles

    Energy Technology Data Exchange (ETDEWEB)

    Courant, T; Roullin, V G; Andry, M C [Institut de Chimie Moleculaire de Reims, CNRS UMR 6229, UFR Pharmacie Reims, 51 rue Cognacq-Jay, F-51100 Reims (France); Cadiou, C; Chuburu, F [Institut de Chimie Moleculaire de Reims, CNRS UMR 6229, UFR des Sciences Exactes et Naturelles, Batiment 18-Europol' Agro, BP 1039, F-51687 Reims Cedex 2 (France); Delavoie, F [Laboratoire de Microscopie Electronique Analytique, INSERM UMRS 926, 21 rue Clement Ader, F-51685 Reims Cedex 2 (France); Molinari, M [Laboratoire de Microscopies et d' Etudes des Nanostructures, UFR des Sciences, Universite de Reims Champagne-Ardenne, 21 rue Clement Ader, F-51685 Reims Cedex 2 (France); Gafa, V, E-mail: gaelle.roullin@univ-reims.fr, E-mail: francoise.chuburu@univ-reims.fr [EA4303 ' Inflammation et Immunite de l' Epithelium Respiratoire' , IFR53, UFR de Pharmacie, Universite de Reims Champagne-Ardenne, 51 rue Cognacq-Jay, F-51100 Reims (France)

    2010-04-23

    A double emulsion-solvent diffusion approach with fully biocompatible materials was used to encapsulate copper complexes within biodegradable nanoparticles, for which the release kinetics profiles have highlighted their potential use for a prolonged circulating administration.

  20. Histopathology of biocompatible hydroxylapatite-polyethylene composite in ossiculoplasty

    NARCIS (Netherlands)

    Meijer, AGW; Segenhout, HM; Albers, FWJ; van de Want, HJL

    2002-01-01

    The biocompatibility of hydroxylapatite-polyethylene composite implants (HAPEX, Smith and Nephew) was investigated in this study. Eleven middle ear prostheses, removed during revision surgery, have been examined by light microscopy, transmission electron microscopy and scanning electron microscopy.

  1. Choice of blood rheology model has minor impact on computational assessment of shear stress mediated vascular risk

    CERN Document Server

    Bernabeu, Miguel O; Groen, Derek; Carver, Hywel B; Hetherington, James; Krüger, Timm; Coveney, Peter V

    2012-01-01

    Perturbations to the homeostatic distribution of mechanical forces exerted by blood on the endothelial layer have been correlated with vascular pathologies including intracranial aneurysms and atherosclerosis. Recent computational work suggests that in order to correctly characterise such forces, the shear-thinning properties of blood must be taken into account. To the best of our knowledge, these findings have never been compared against experimentally observed pathological thresholds. In the current work, we apply the three-band diagram (TBD) analysis due to Gizzi et al. to assess the impact of the choice of blood rheology model on a computational model of the right middle cerebral artery. Our results show that the differences between the wall shear stress predicted by a Newtonian model and the well known Carreau-Yasuda generalized Newtonian model are only significant if the vascular pathology under study is associated with a pathological threshold in the range 0.94 Pa to 1.56 Pa, where the results of the T...

  2. Dose assessment by quantification of chromosome aberrations and micronuclei in peripheral blood lymphocytes from patients exposed to gamma radiation

    Energy Technology Data Exchange (ETDEWEB)

    Silva-Barbosa, Isvania; Pereira-MagnataI, Simey; Amaral, Ademir [Pernambuco Univ., Recife, PE (Brazil). Dept. de Energia Nuclear. Grupo de Estudos em Radioprotecao e Radioecologia - GERAR; Sotero, Graca [Fundacao de Hematologia e Hemoterapia, Recife, PE (Brazil); Melo, Homero Cavalcanti [Hospital do Cancer, Recife, PE (Brazil). Centro de Radioterapia de Pernambuco]. E-mail: isvania@uol.com.br

    2005-07-15

    Scoring of unstable chromosome aberrations (dicentrics, rings and fragments) and micronuclei in circulating lymphocytes are the most extensively studied biological means for estimating individual exposure to ionizing radiation (IR), which can be used as complementary methods to physical dosimetry or when the latter cannot be performed. In this work, the quantification of the frequencies of chromosome aberrations and micronuclei were carried out based on cytogenetic analyses of peripheral blood samples from 5 patients with cervical uterine cancer following radiotherapy in order to evaluate the absorbed dose as a result of partial-body exposure to 60Co source. Blood samples were collected from each patient in three phases of the treatment: before irradiation, 24 h after receiving 0.08 Gy and 1.8 Gy, respectively. The results presented in this report emphasize biological dosimetry, employing the quantification of chromosome aberrations and micronuclei in lymphocytes from peripheral blood, as an important methodology of dose assessment for either whole or partial-body exposure to IR.

  3. Changing the "Normal Range" for Blood Pressure from 140/90 to 130/Any Improves Risk Assessment.

    Science.gov (United States)

    Fulks, Michael; Stout, Robert L; Dolan, Vera F

    2015-01-01

    Objective .- Redefine the "normal" reference range for blood pressure from <140/90 to one that more effectively identifies individuals with increased mortality risk. Method .- Data from the recently published 2014 CRL blood pressure study was used. It includes 2,472,706 life insurance applicants tested by Clinical Reference Laboratory from 1993 to 2007 with follow-up for vital status using the September 2011 Social Security Death Master File. Various upper limits of blood pressure (BP in mm Hg) were evaluated to determine if any was superior to the current, commonly used limit of 140/90 in identifying individuals with increased mortality risk. Results .- An alternative reference range using a systolic BP (SBP) <130 with any diastolic BP (DBP) included 84% of life insurance applicants. It had a lower mortality rate and narrower range of relative risk than <140/90, including 89% as many applicants but only 68% as many deaths. This pattern of lives and deaths was consistent across age and sex. Conclusion .- Switching to a "normal" reference range of SBP <130 offers superior risk assessment relative to using BP <140/90 while still including a sufficient percentage of the population.

  4. ASSESSMENT OF VERTEBRAL ARTERIES BLOOD FLOW SPECTRAL DOPPLER INDICES IN COMPARISON WITH INTERNAL AND COMMON CAROTID ARTERIES BLOOD FLOW SPECTRAL DOPPLER INDICES

    Directory of Open Access Journals (Sweden)

    H. Mazaher

    2007-05-01

    Full Text Available Vertebrobasilar insufficiency is the cause of cerebrovascular accidents in 20% of cases. There are few reports regarding spectral Doppler indices (SDIs of vertebral arteries (VAs normal blood flow. The objective of this study was to provide basic reference data about SDIs of VAs normal blood flow separately and in comparison with internal carotid arteries (ICAs and common carotid arteries (CCAs normal blood flows SDIs. This cross-sectional study performed on 70 normal patients. Color Doppler sonography (CDS and spectral Doppler sonography (SDS of right and left VAs (RVA and LVA, right and left CCAs (RCCA and LCCA, right and left ICAs (RICA and LICA, were performed. The mean PSV, EDV, and RI values of RVA blood flow were as 41.60 ± 9.6 cm/s, 14.60 ± 3.7 cm/s and 0.65 ± 0.06, and the mean PSV, EDV and RI values of LVA blood flow were as 42.20 ± 10.2 cm/s, 15.20 ± 4.2 cm/s, and 0.64 ± 0.05, respectively. There was not statistically significant difference between the mean PSV, EDV and RI values of RVA and LVA blood flows. The mean PSV and EDV values of VAs blood flows were significantly lower than the values of CCAs and ICCAs blood flows, respectively. The mean RI value of VAs blood flows was significantly lower than the mean RI Value of CCAs blood flows, but there was not statistically significant difference between the mean RI value of VAs blood flows and the mean RI value of ICAs blood flows.

  5. Blood compatibility assessment of polymers used in drug eluting stent coatings.

    Science.gov (United States)

    Szott, Luisa Mayorga; Irvin, Colleen A; Trollsas, Mikael; Hossainy, Syed; Ratner, Buddy D

    2016-06-15

    Differences in thrombosis rates have been observed clinically between different drug eluting stents. Such differences have been attributed to numerous factors, including stent design, injury created by the catheter delivery system, coating application technologies, and the degree of thrombogenicity of the polymer. The relative contributions of these factors are generally unknown. This work focuses on understanding the thrombogenicity of the polymer by examining mechanistic interactions with proteins, human platelets, and human monocytes of a number of polymers used in drug eluting stent coatings, in vitro. The importance for blood interactions of adsorbed albumin and the retention of albumin was suggested by the data. Microscopic imaging and immunostaining enhanced the interpretation of results from the lactate dehydrogenase cell counting assay and provided insight into platelet interactions, total quantification, and morphometry. In particular, highly spread platelets may be surface-passivating, possibly inhibiting ongoing thrombotic events. In many of the assays used here, poly(vinylidene fluoride-co-hexafluoropropylene) (PVDF-HFP) showed a differentiated protein deposition pattern that may contribute to the explanation of the consistently thromboresistant blood-materials interaction for fluororpolymers cited in literature. These results are supportive of one of several possible factors contributing to the good thromboresistant clinical safety performance of PVDF-HFP coated drug eluting stents.

  6. At what age group blood pressure discontinue to increase? An assessment using change-point analysis

    Directory of Open Access Journals (Sweden)

    Khalib A. Latiff

    2010-05-01

    Full Text Available Aim To study at what age group blood pressure ceases to increase for women and men.Methods Applying change-point technique, we used our existing database - mega base-line cross-sectional Hulu Langat Health Study that was initiated in 2000 - to locate the most appropriate age limit in planning promotive, preventive and controlling strategies against systolic hypertension.Results Systolic hypertension was found to be constantly increasing for both gender right from the early age until the middle age group. However, women achieved the systolic peak 15 years earlier (at 41-45 years old than men (at 56-60 years old. Systolic blood pressure was steadily declined after the peak.Conclusions Hypertension intervention, we recommend age before 40 (women and 55 (men be the most appropriate period to apply various public health intervention, after that, the action must be exclusively curative. (Med J Indones 2010; 19:136-41Keywords: change-point analysis, public health intervention, systolic hypertension

  7. Comparison of arterial and capillary blood gas values in poisoning department assessment.

    Science.gov (United States)

    Eizadi-Mood, Nastaran; Alfred, Sam; Yaraghi, Ahmad; Huynh, Chanh; Moghadam, Ali Shayesteh

    2009-10-01

    The aim of this study was to compare simultaneously obtained arterial and capillary blood gas (CBG) values in comatose-poisoned patients presented with stable vital signs. Forty-five adult patients with a diagnosis of coma because of poisoning and stable vital signs were included in this prospective study. With respect to pH, the arterial blood gas (ABG) and CBG values correlated satisfactorily (r(2) = .91) and had an acceptable limit of agreements (LOAs; -0.04 to 0.06). With respect to base excess (BE), the ABG and CBG values correlated well (r(2) = .85), but their 95% LOAs seem too wide to allow substitution (-4.4 to 2.7). PCO(2) (r(2) = .61), HCO(3) (r(2) = .71) and PO(2) (r(2) = .53) correlated less reliably. A capillary PCO(2) of 51.7 mm Hg had a sensitivity of 100% and a specificity of 95.12% for detecting hypercarbia (area under the curve, 0.99; 95% Confidence Interval, 0.90-0.99; p analysis for pH may be a reliable substitute for ABG analysis in the initial evaluation of patients presenting with coma and stable vital signs to the poisoning emergency department (PED). Subsequent ABG may be required in patients with capillary PCO(2) > 51.7 mm Hg.

  8. [Assessment of relative biological effectiveness of tritium using chromosome aberration frequency in human blood lymphocytes].

    Science.gov (United States)

    Snigireva, G P; Khaĭmovich, T I; Nagiba, V I

    2010-01-01

    The aim of this work is to determine Relative Biological Effectiveness (RBE) of tritium beta-irradiation using chromosome aberration frequency in peripheral blood lymphocytes after radiation exposure in vitro and in vivo. The results of the experimental estimation of tritium beta-irradiation RBE in comparison with 60Co gamma-irradiation using analysis of unstable chromosome aberration frequencies in peripheral blood lymphocytes in reference to concrete conditions of the investigation were presented. It was demonstrated that tritium beta-irradiation is in total more effective than gamma-irradiation up to 1 Gy. RBE of tritium beta-irradiation was determined as 2.2 at minimum doses and decreased at higher doses (1 Gy) up to 1.25. For the first time results of the comparative analysis of frequencies of stable chromosome aberrations in two groups of professional nuclear workers (town Sarov) exposed to chronic tritium beta- and gamma-irradiation in remote period were presented. The grater RBE of tritium beta-irradiation was demonstrated. It has been estimated as 2.5.

  9. Blood flow measurement using digital subtraction angiography for assessing hemodialysis access function

    Science.gov (United States)

    Koirala, Nischal; Setser, Randolph M.; Bullen, Jennifer; McLennan, Gordon

    2017-03-01

    Blood flow rate is a critical parameter for diagnosing dialysis access function during fistulography where a flow rate of 600 ml/min in arteriovenous graft or 400-500 ml/min in arteriovenous fistula is considered the clinical threshold for fully functioning access. In this study, a flow rate computational model for calculating intra-access flow to evaluate dialysis access patency was developed and validated in an in vitro set up using digital subtraction angiography. Flow rates were computed by tracking the bolus through two regions of interest using cross correlation (XCOR) and mean arrival time (MAT) algorithms, and correlated versus an in-line transonic flow meter measurement. The mean difference (mean +/- standard deviation) between XCOR and in-line flow measurements for in vitro setup at 3, 6, 7.5 and 10 frames/s was 118+/-63 37+/-59 31+/-31 and 46+/-57 ml/min respectively while for MAT method it was 86+/-56 57+/-72 35+/-85 and 19+/-129 ml/min respectively. The result of this investigation will be helpful for selecting candidate algorithms while blood flow computational tool is developed for clinical application.

  10. Facile Fabrication and Characterization of a PDMS-Derived Candle Soot Coated Stable Biocompatible Superhydrophobic and Superhemophobic Surface.

    Science.gov (United States)

    Iqbal, R; Majhy, B; Sen, A K

    2017-09-13

    We report a simple, inexpensive, rapid, and one-step method for the fabrication of a stable and biocompatible superhydrophobic and superhemophobic surface. The proposed surface comprises candle soot particles embedded in a mixture of PDMS+n-hexane serving as the base material. The mechanism responsible for the superhydrophobic behavior of the surface is explained, and the surface is characterized based on its morphology and elemental composition, wetting properties, mechanical and chemical stability, and biocompatibility. The effect of %n-hexane in PDMS, the thickness of the PDMS+n-hexane layer (in terms of spin coating speed) and sooting time on the wetting property of the surface is studied. The proposed surface exhibits nanoscale surface asperities (average roughness of 187 nm), chemical compositions of soot particles, very high water and blood repellency along with excellent mechanical and chemical stability and excellent biocompatibility against blood sample and biological cells. The water contact angle and roll-off angle is measured as 160° ± 1° and 2°, respectively, and the blood contact angle is found to be 154° ± 1°, which indicates that the surface is superhydrophobic and superhemophobic. The proposed superhydrophobic and superhemophobic surface offers significantly improved (>40%) cell viability as compared to glass and PDMS surfaces.

  11. Biocompatible glass-ceramic materials for bone substitution.

    Science.gov (United States)

    Vitale-Brovarone, Chiara; Verné, Enrica; Robiglio, Lorenza; Martinasso, Germana; Canuto, Rosa A; Muzio, Giuliana

    2008-01-01

    A new bioactive glass composition (CEL2) in the SiO(2)-P(2)O(5)-CaO-MgO-K(2)O-Na(2)O system was tailored to control pH variations due to ion leaching phenomena when the glass is in contact with physiological fluids. CEL2 was prepared by a traditional melting-quenching process obtaining slices that were heat-treated to obtain a glass-ceramic material (CEL2GC) that was characterized thorough SEM analysis. Pre-treatment of CEL2GC with SBF was found to enhance its biocompatibility, as assessed by in vitro tests. CEL2 powder was then used to synthesize macroporous glass-ceramic scaffolds. To this end, CEL2 powders were mixed with polyethylene particles within the 300-600 microm size-range and then pressed to obtain crack-free compacted powders (green). This was heat-treated to remove the organic phase and to sinter the inorganic phase, leaving a porous structure. The biomaterial thus obtained was characterized by X-ray diffraction, SEM equipped with EDS, density measurement, image analysis, mechanical testing and in vitro evaluation, and found to be a glass-ceramic macroporous scaffold with uniformly distributed and highly interconnected porosity. The extent and size-range of the porosity can be tailored by varying the amount and size of the polyethylene particles.

  12. Spheroid model study comparing the biocompatibility of Biodentine and MTA.

    Science.gov (United States)

    Pérard, Matthieu; Le Clerc, Justine; Watrin, Tanguy; Meary, Fleur; Pérez, Fabienne; Tricot-Doleux, Sylvie; Pellen-Mussi, Pascal

    2013-06-01

    The primary objective of this study was to assess the biological effects of a new dentine substitute based on Ca₃SiO₅ (Biodentine™) for use in pulp-capping treatment, on pseudo-odontoblastic (MDPC-23) and pulp (Od-21) cells. The secondary objective was to evaluate the effects of Biodentine and mineral trioxide aggregate (MTA) on gene expression in cultured spheroids. We used the acid phosphatase assay to compare the biocompatibility of Biodentine and MTA. Cell differentiation was investigated by RT-qPCR. We investigated the expression of genes involved in odontogenic differentiation (Runx2), matrix secretion (Col1a1, Spp1) and mineralisation (Alp). ANOVA and PLSD tests were used for data analysis. MDPC-23 cells cultured in the presence of MTA had higher levels of viability than those cultured in the presence of Biodentine and control cells on day 7 (P = 0.0065 and P = 0.0126, respectively). For Od-21 cells, proliferation rates on day 7 were significantly lower in the presence of Biodentine or MTA than for control (P MTA than in those cultured in the presence of Biodentine and in control cells. Biodentine and MTA may modify the proliferation of pulp cell lines. Their effects may fluctuate over time, depending on the cell line considered. The observed similarity between Biodentine and MTA validates the indication for direct pulp-capping claimed by the manufacturers.

  13. Assessment of blood loss and need for transfusion during bimaxillary surgery with or without maxillary setback.

    Science.gov (United States)

    Choi, Bong-Kyoon; Yang, Eun-Jung; Oh, Kap Sung; Lo, Lun-Jou

    2013-02-01

    The objective of this study was to compare the blood loss, transfusion needs, and operation times in subjects who underwent bimaxillary surgery with versus without maxillary setback. A retrospective chart review was completed in all patients who underwent bimaxillary surgery from March 2009 to August 2010. The inclusion criterion was the availability of a complete chart record. Patients were divided into 1 of 2 groups based on maxillary setback procedure. The predictive variable was the treatment group. The primary outcome variable was blood loss as measured by the change in hemoglobin. The secondary outcome variables were operation time and transfusion need. The other study variables were a patient's characteristics (ie, age and gender). Mann-Whitney test was performed to compare unpaired samples. Student t test was performed to compare operation time. Multiple regression analysis was used to analyze the adjusted relation among the study variables. There were 82 patients (17 male and 65 female; mean age, 28.0 ± 4.9 yr; age range, 18 to 35 yr) who underwent bimaxillary surgery in this study. The mean hemoglobin decreases were 1.72 g/dL (standard deviation, 0.67 g/dL) in the nonsetback group and 2.37 g/dL (standard deviation, 0.76 g/dL) in the setback group. The average operation times were 158.24 ± 30.36 minutes (range, 127.88 to 188.6 min) in the nonsetback group and 194.35 ± 29.20 minutes (range, 165.15 to 223.55 min) in the setback group. Transfusion was not performed in any patient. After adjusting for potential factors, the multiple regression model showed that the treatment group was associated with blood loss (P < .0001) and operation time (P < .0001). This study shows that intraoperative bleeding and operation time increased significantly in patients undergoing mandibular ramus osteotomy and Le Fort I osteotomy with maxillary setback. However, transfusion generally is not required during 2-jaw surgery, regardless of maxillary setback. Copyright © 2013

  14. Introducing Contactless Blood Pressure Assessment Using a High Speed Video Camera.

    Science.gov (United States)

    Jeong, In Cheol; Finkelstein, Joseph

    2016-04-01

    Recent studies demonstrated that blood pressure (BP) can be estimated using pulse transit time (PTT). For PTT calculation, photoplethysmogram (PPG) is usually used to detect a time lag in pulse wave propagation which is correlated with BP. Until now, PTT and PPG were registered using a set of body-worn sensors. In this study a new methodology is introduced allowing contactless registration of PTT and PPG using high speed camera resulting in corresponding image-based PTT (iPTT) and image-based PPG (iPPG) generation. The iPTT value can be potentially utilized for blood pressure estimation however extent of correlation between iPTT and BP is unknown. The goal of this preliminary feasibility study was to introduce the methodology for contactless generation of iPPG and iPTT and to make initial estimation of the extent of correlation between iPTT and BP "in vivo." A short cycling exercise was used to generate BP changes in healthy adult volunteers in three consecutive visits. BP was measured by a verified BP monitor simultaneously with iPTT registration at three exercise points: rest, exercise peak, and recovery. iPPG was simultaneously registered at two body locations during the exercise using high speed camera at 420 frames per second. iPTT was calculated as a time lag between pulse waves obtained as two iPPG's registered from simultaneous recoding of head and palm areas. The average inter-person correlation between PTT and iPTT was 0.85 ± 0.08. The range of inter-person correlations between PTT and iPTT was from 0.70 to 0.95 (p high speed camera can be potentially utilized for unobtrusive contactless monitoring of abrupt blood pressure changes in a variety of settings. The initial prototype system was able to successfully generate approximation of pulse transit time and showed high intra-individual correlation between iPTT and BP. Further investigation of the proposed approach is warranted.

  15. ASSESSMENT OF ERYTHROCYTE PERIPHERAL BLOOD AND ACTIVITY OF HEMOST ASIS IN PATIENTS WITH CER VICAL CANCER

    Directory of Open Access Journals (Sweden)

    N. I. Stuklov

    2016-01-01

    Full Text Available Despite the availability and informative value of methods that facilitate the diagnosis, cervical cancer (CC does not lose its leading position as one of the most common cancers of the reproductive system in women worldwide. High prevalence of anemia and thrombotic complications in this group determines not only the quality of life of patients, but the outcome of the underlying disease. The purpose of the study was to determine the patterns of change in erythrocyte of peripheral blood and the state of vascular-platelet and coagulation hemostasis in patients with cervical cancer depending on the stage of disease and histological variant of the tumor.Materials and methods. We investigated the performance of erythron, thrombocytic and coagulation hemostasis in 74 patients with cervical cancer (mean age 46,49 ± 11,78 years. Blood analysis was performed in the initial evaluation of patients in the prehospital phase.Results. It is proved that the spread of the tumor outside the cervix exerts a systemic influence on hematopoiesis, hemostasis, significantly increasing the risk of venous thromboembolism and hematogenous dissemination of the disease (metastasis. In the case of adenocarcinoma and dimorphic (glandular-squamous cervical cancer we proved the significant increase in soluble fibrin-monomer complexes, fibrinogen, and with glandular-squamous-cell cervical cancer and hypercoagulability (decrease thrombin time, which requires mandatory and differentiated prevention of venous thromboembolism even in the early stages of these morphological variants of the disease.Conclusions. Cervical cancer has a systemic effect on the blood and hemostasis. A statistically significant decrease in the concentration of hemoglobin and increased erythrocyte sedimentation rate is determined in the second stage of the disease. The increase in the prevalence of cervical cancer and the presence of glandular component in the morphological

  16. Immune status assessment by abundance of IFN-alpha and IFN-gamma mRNA in chicken blood.

    Science.gov (United States)

    Novak, R; Ester, K; Savić, V; Sekellick, M J; Marcus, P I; Lowenthal, J W; Vainio, O; Ragland, W L

    2001-08-01

    Avian diseases, including such viral infection as infectious bursal disease, infectious anemia, and Marek's disease, often cause immunosuppression, leading to more severe infection, problems with secondary infection, and inadequate responses to vaccination. Immunosuppression thus causes serious economic losses in commercial poultry production. To date, methods for assessing immune status have been too slow to be of practical help. Reasoning that immunosuppression should be reflected by reduced production of interferons (IFN) in response to a viral antigen, we have developed competitive nucleic acid hybridization microtiter plate assays for chicken IFN-alpha (ChIFN-alpha) and ChIFN-gamma mRNA. To evaluate the assay, chickens were challenged with inactivated Newcastle disease virus (iNDV). Whole blood samples were collected at various times subsequently and preserved with a cationic detergent. Later, total RNA was extracted, and mRNA for both ChIFN-alpha and ChIFN-gamma was measured. Both rose from undetectable levels to reach a peak by 4 h, remained high for about 3 days, and fell to undetectable levels by day 5. Results were similar in chickens aged between 1 and 28 days. In later experiments, blood was collected 4 h after viral challenge. When chickens were immunosuppressed by administering 4-5 mg cyclophosphamide (CY) daily for 3 days and challenged with iNDV, they transcribed less ChIFN-alpha and ChIFN-gamma mRNA, and their antibody response was impaired. Our results suggest that suspected immunosuppression in a commercial flock could be assessed within 2-3 days by challenging birds with iNDV and measuring the amounts of ChIFN-alpha and ChIFN-gamma mRNA in blood obtained 2-4 h later.

  17. Biocompatibility of mannuronic acid-rich alginates.

    Science.gov (United States)

    Klöck, G; Pfeffermann, A; Ryser, C; Gröhn, P; Kuttler, B; Hahn, H J; Zimmermann, U

    1997-05-01

    Highly purified algin preparations free of adverse contaminants with endotoxins and other mitogens recently became available by a new purification process (Klöck et al., Appl. Microbiol. Biotechnol., 1994, 40, 638-643). An advantage of this purification protocol is that it can be applied to alginates with various ratios of mannuronic acid to guluronic acid. High mannuronic acid alginate capsules are of particular practical interest for cell transplantation and for biohybrid organs, because mannuronate-rich alginates are usually less viscous, allowing one to make gels with a higher alginate content. This will increase their stability and reduce the diffusion permeability and could therefore protect immobilized cells more efficiently against the host immune system. Here we report the biocompatibility of purified, mannuronic acid-rich alginate (68% mannuronate residues) in a series of in vitro, as well as in vivo, assays. In contrast to raw alginate extracts, the purified product showed no mitogenic activity towards murine lymphocytes in vitro. Its endotoxin content was reduced to the level of the solvent. Animal studies with these new, purified algin formulations revealed the absence of a mitogen-induced foreign body reaction, even when the purified material (after cross-linking with Ba2+ ions) is implanted into animal models with elevated macrophage activity (diabetes-prone BB/OK rat). Thus, alginate capsules with high mannuronic acid content become available for applications such as implantation. In addition to the utilization as implantable cell reactors in therapy and biotechnology, these purified algins have broad application potential as ocular fillings, tissue replacements, microencapsulated growth factors and/or interleukins or slow-release dosage forms of antibodies, surface coatings of sensors and other invasive medical devices, and in encapsulation of genetically engineered cells for gene therapy.

  18. Improving Corrosion Resistance and Biocompatibility of Magnesium Alloy by Sodium Hydroxide and Hydrofluoric Acid Treatments

    Directory of Open Access Journals (Sweden)

    Chang-Jiang Pan

    2016-12-01

    Full Text Available Owing to excellent mechanical property and biodegradation, magnesium-based alloys have been widely investigated for temporary implants such as cardiovascular stent and bone graft; however, the fast biodegradation in physiological environment and the limited surface biocompatibility hinder their clinical applications. In the present study, magnesium alloy was treated by sodium hydroxide (NaOH and hydrogen fluoride (HF solutions, respectively, to produce the chemical conversion layers with the aim of improving the corrosion resistance and biocompatibility. The results of attenuated total reflectance Fourier transform infrared spectroscopy (ATR-FTIR and X-ray photoelectron spectroscopy (XPS indicated that the chemical conversion layers of magnesium hydroxide or magnesium fluoride were obtained successfully. Sodium hydroxide treatment can significantly enhance the surface hydrophilicity while hydrogen fluoride treatment improved the surface hydrophobicity. Both the chemical conversion layers can obviously improve the corrosion resistance of the pristine magnesium alloy. Due to the hydrophobicity of magnesium fluoride, HF-treated magnesium alloy showed the relative better corrosion resistance than that of NaOH-treated substrate. According to the results of hemolysis assay and platelet adhesion, the chemical surface modified samples exhibited improved blood compatibility as compared to the pristine magnesium alloy. Furthermore, the chemical surface modified samples improved cytocompatibility to endothelial cells, the cells had better cell adhesion and proliferative profiles on the modified surfaces. Due to the excellent hydrophilicity, the NaOH-treated substrate displayed better blood compatibility and cytocompatibility to endothelial cells than that of HF-treated sample. It was considered that the method of the present study can be used for the surface modification of the magnesium alloy to enhance the corrosion resistance and biocompatibility.

  19. Assessment of the levels of polybrominated diphenyl ethers in blood samples from Guadalajara, Jalisco, Mexico.

    Science.gov (United States)

    Orta-Garcia, Sandra Teresa; León-Moreno, Lilia Carolina; González-Vega, Carolina; Dominguez-Cortinas, Gabriela; Espinosa-Reyes, Guillermo; Pérez-Maldonado, Iván N

    2012-10-01

    The purpose of this study was to measure levels of polybrominated diphenyl ethers (PBDEs) in the blood of children (50 individuals) living in Guadalajara, Jalisco, Mexico. We analyzed six PBDE congeners by gas chromatography-mass spectrometry. Total PBDE levels ranged from not detectable (nd) to 15.2 μg/L on a whole-weight basis and from nd to 6,435 ng/g lipid on a lipid-weight basis. The dominant congener in our study was BDE-153, followed by BDE-154, BDE-99, BDE-100, and BDE-47. Levels of BDE-209 were below the detection limit. Our data indicate that children living in the areas studied in this work are exposed to high levels of PBDEs.

  20. SPECIFICITIES OF THE SUBSET PROFILE OF PERIPHERAL BLOOD IN PATIENTS WITH GLIOBLASTOMA: PATHOGENETIC AND CLINICAL ASSESSMENTS

    Directory of Open Access Journals (Sweden)

    V. A. Chumakov

    2006-01-01

    Full Text Available Abstract. In glioblastoma (GB, it is necessary to take into consideration GB-associated secondary immunodeficiency (SID, so-called syndrome of tumor-associated SID (STASID. Cell subsets having effector and regulatory functions, play an important role in developing STASID, and their proportions in patients with different forms of GB can be of pathogenetic importance and have clinical value for treatment and rehabilitation scheduling as well. The most pathogenically and clinically important features of cell subsets profile of peripheral blood were analyzed in patients with different clinical and morphological types of GB. The patients were divided into three groups, i.e., groups I and II were formed by patients with STASID (marked and slightly marked SID, accordingly; group III – patients with SIDTAS (tumor-associated autoimmune syndrome, associated with SID. Marked suppression of cell immunity is typical of group I - imbalance in T-lymphocytes, in a number of specific subsets, and in subsets clusters, as well as disproportions in the immunoregulatory indexes. In group II, the subset profiles of blood were slightly different from the norm. In patients with SIDTAS, activation of cell immunity was evident, forming SID with signs of autoimmune syndrome, affecting effector and regulatory chains of immunity, and influencing the severity and forecast of the disease. Specific features of the immune status in patients with GB identified can be resulted from different clinicalmorphological types of the tumor; the latter are to be considered in differential diagnostics of clinical course of GB and in scheduling of clinical-immunological efficient anti-tumor pharmacotherapy in pre- and postoperative periods.

  1. [Assessment of the response of peripheral blood mononuclear leukocytes on Helicobacter pylori infection in children].

    Science.gov (United States)

    Czkwianianc, Elzbieta; Jarosińska, Agnieszka; Chmiela, Magdalena; Bajer, Anna; Bak-Romaniszyn, Leokadia; Płaneta-Małecka, Izabela; Rudnicka, Wiesława

    2003-01-01

    In the study the proliferative response of peripheral blood mononuclear leukocytes (PBML) from children with chronic dyspepsia (chr. d) to H.p. antigens was investigated. From 38 children aged 7-18, with chr. d., blood was collected just before upper GI endoscopy. Twenty one patients were found to be H.p. (+). PBML were used for the cultures and were stimulated with heat-killed H.p. G27 bacteria, heated and unheated glycine extract (GE) of H.p. G27 or with H.p. LPS containing Lewis X and Lewis Y determinants, in the presence or absence IL-2. The cell proliferation was estimated on the basis of [3H] - thymidine incorporation. In the cultures, the phenotype of responding cells was determined by an EIA with monoclonal antibody to human CD3, CD4 and CD8. PBML from patients H.p. (-), responded to killed H.p. bacteria and to heated GE more frequently and more intensively than PBML from the H.p.(+). IL-2 enhanced PBML response to these antigens. Unheated GE did not induce PBML proliferation even in the cultures with IL-2. LPS alone induced proliferation of PBML from 3 patients (2 H.p. - and 1 H.p.+). However, in the presence of IL-2, LPS induced proliferation of PBML from 15 patients. In the cultures of PBML stimulated with whole bacteria or heated EG, T cells dominated. In the cultures of PBML from H.p. (+) we found a higher percentage of CD8 cells in comparison with the cultures of PBML from H.p. (-). Data demonstrate a significant variation in the response of PBML from dyspeptic children to H.p. antigens.

  2. Biochemical assessment of growth factors and circulation of blood components contained in the different fractions obtained by centrifugation of venous blood.

    Science.gov (United States)

    Corigiano, M; Ciobanu, G; Baldoni, E; Pompa, G

    2014-01-01

    The aim of this study was to evaluate a biochemical marker with different elements of a normal blood serum and centrifuged blood serum after a different rotation system. For this technique, we used five fractions of a blood Concentrated Growth Factors system (bCGF) and a particular device for the different rotation program. Blood samples were collected from 10 volunteers aged between 35 and 55 in the Operative Unit of the “Sapienza” University of Rome with only a fraction of different biochemical elements. Through an individual blood phase separator tube of venous blood, active factions of serum and 4 fractions of red buffy coat were taken. The biochemical markers with 14 elements were examined at times: P1-11 minutes, P2-12minutes, P3-15 minutes. Exclusively biological materials which are normally applied in the regeneration techniques for different defects and lesions were used with this technique. After specific rotation programs, a different result was obtained for each cycle: P1, P2, P3. In test tubes obtained by separated blood, we observed a higher concentration of proteins, ions, and other antigens compared to normal blood plasma. Examining the biochemical results of different elements, we observed an increase (P≤0,01). Since each person’s DNA is different, we could not have the same results in 5 fractions of blood concentration, we did, however, find a good increase in only a fraction of proteins, immunoglobulin and different ions. We obtained five fractions after centrifugation, and we had an increase in different biochemical elements compared to normal blood (P≤0,01) which is significant at different times. These biochemical elements were stimulated by different growth factors, which are used by the immune system, and they induced the formation of hard and soft tissues and good regeneration.

  3. Assessment of whole blood thrombosis in a microfluidic device lined by fixed human endothelium

    NARCIS (Netherlands)

    Jain, Abhishek; Meer, van der Andries D.; Papa, Anne-Laure; Barrile, Riccardo; Lai, Angela; Schlechter, Benjamin L.; Otieno, Monicah A.; Louden, Calvert S.; Hamilton, Geraldine A.; Michelson, Alan D.; Frelinger, Andrew L.; Ingber, Donald E.

    2016-01-01

    The vascular endothelium and shear stress are critical determinants of physiological hemostasis and platelet function in vivo, yet current diagnostic and monitoring devices do not fully incorporate endothelial function under flow in their assessment and, therefore, they can be unreliable and inaccur

  4. Fabrication and biocompatibility in vitro of potassium titanate biological thin film/titanium alloy biological composite

    Institute of Scientific and Technical Information of China (English)

    QI Yumin; HE Yun; CUI Chunxiang; LIU Shuangjin; WANG Huifen

    2007-01-01

    A potassium titanate biological thin film/titanium alloy biological composite was fabricated by way of bionic chemistry.The biocompatibility fn vitro of Ti-15Mo-3Nb and the potassium titanate biological thin film/titanium alloy was studied using simulated body fluid cultivation,kinetic clotting of blood and osteoblast cell cultivation experiments in vitro.By comparing the biological properties of both materials,the following conclusions can be obtained:(1)The deposition of a calcium phosphate layer was not found on the surface of Ti-15Mo-3Nb,so it was bioinert.Because the network of potassium titanate biological thin film could induce the deposition of a calcium phosphate layer,this showed that it had excellent bioactivity.(2)According to the values of kinetic clotting,the blood coagulation time of the potassium titanate biological thin film was more than that of Ti-15Mo-3Nb.It was obvious that the potassium titanate biological thin film possessed good hemocompatibility.(3)The cell compatibility of both materials was very good.However,the growth trend and multiplication of osteoblast cells on the surface of potassium titanate biological thin film was better,which made for the concrescence of wounds during the earlier period.As a result,the potassium titanate biological thin film/titanium alloy showed better biocompatibility and bioactivity.

  5. Performance of a newly developed implantable centrifugal blood pump.

    Science.gov (United States)

    Tsukiya, T; Taenaka, Y; Tatsumi, E; Takano, H

    2001-01-01

    The performance of the newly developed implantable centrifugal blood pump was investigated in vitro. The pump was developed with the end goal of building a versatile system that includes a left ventricular assist system with an internal secondary battery or an implantable biventricular assist system with two implantable blood pumps. The hydrodynamic characteristics and efficiency of the blood pump were evaluated, and the mechanical damage to the blood caused by the blood pump was assessed through a hemolysis test using fresh goat blood. The pump could generate 120 mm Hg at a flow rate of 5 L/min and a motor speed of 2,500 rpm. The electric input power to the pump was approximately 5 watts under these working conditions. The hemolysis caused by the pump was a bit higher than that by the former model, but stayed within an acceptable range. Performance of the pump in vitro was considered sufficient for a left ventricular assist device, although further design improvement is necessary in terms of hemolysis and system efficiency to improve biocompatibility of the pump.

  6. Biocompatibility testing of a silicone maxillofacial prosthetic elastomer: soft tissue study in primates.

    Science.gov (United States)

    Wolfaardt, J F; Cleaton-Jones, P; Lownie, J; Ackermann, G

    1992-08-01

    Little information exists on the biocompatibility of maxillofacial prosthetic materials. Cosmesil material is a purpose-designed facial prosthetic elastomer that has an established clinical profile in humans but results of biocompatibility testing have not been published. Cosmesil, acrylic resin (positive control), black surgical gutta-percha (negative control), and Silastic 382 material (Dow Corning, Midland, Mich.) (reference control) were processed as custom-designed implants. The implants were inserted into five chacma baboons for a 12-week period in intraosseous, subperiosteal, submucosal, and intramuscular sites. The histologic assessment was based on a modified form of the FDI-ISO Technical Report 7405 for subcutaneous implants. An evaluation was made of capsule formation and inflammatory response. The statistical analysis involved a three-way ANOVA and a Tukey-Kramer Student range test. The critical level of statistical significance chosen was p less than 0.05. The study found that gutta-percha provoked a statistically significantly thicker capsule and a severe inflammatory response. Acrylic resin, Cosmesil material, and Silastic 382 material produced capsule formations and an inflammatory response that did not differ significantly. Cosmesil material is not manufactured as an implant material, but from the present findings it is considered acceptably biocompatible for its intended use where there may be contact with internal tissue spaces that are contiguous to external surfaces.

  7. Assessment of the toxic potential of engineered metal oxide nanomaterials using an acellular model: citrated rat blood plasma.

    Science.gov (United States)

    Gormley, Patrick Thomas; Callaghan, Neal Ingraham; MacCormack, Tyson James; Dieni, Christopher Anthony

    2016-10-01

    Citrated Sprague-Dawley rat blood plasma was used as a biologically relevant exposure medium to assess the acellular toxic potential of two metal oxide engineered nanomaterials (ENMs), zinc oxide (nZnO), and cerium oxide (nCeO2). Plasma was incubated at 37 °C for up to 48 h with ENM concentrations ranging between 0 and 200 mg/L. The degree of ENM-induced oxidation was assessed by assaying for reactive oxygen species (ROS) levels using dichlorofluorescein (DCF), pH, ferric reducing ability of plasma (FRAP), lipase activity, malondialdehyde (MDA), and protein carbonyls (PC). Whereas previous in vitro studies showed linear-positive correlations between ENM concentration and oxidative damage, our results suggested that low concentrations were generally pro-oxidant and higher concentrations appeared antioxidant or protective, as indicated by DCF fluorescence trends. nZnO and nCeO2 also affected pH in a manner dependent on concentration and elemental composition; higher nZnO concentrations maintained a more alkaline pH, while nCeO2 tended to decrease pH. No other biomarkers of oxidative damage (FRAP, MDA, PC, lipase activity) showed changes at any ENM concentration or time-point tested. Differential dissolution of the two ENMs was also observed, where as much as ∼31.3% of nZnO was instantaneously dissolved to Zn(2+ )and only negligible nCeO2 was degraded. The results suggest that the direct oxidative potential of nZnO and nCeO2 in citrated rat blood plasma is low, and that a physiological or immune response is needed to generate appreciable damage biomarkers. The data also highlight the need for careful consideration when selecting a model for assessing ENM toxicity.

  8. [Evaluation of biocompatibility of Ti-6Al-4V scaffolds fabricated by electron beam melting].

    Science.gov (United States)

    Wang, H; Zhao, B J; Yan, R Z; Wang, C; Luo, C C; Hu, M

    2016-11-09

    Objective: To investigate the biocompatibility of Ti-6Al-4V scaffolds fabricated by electron beam melting(EBM). Methods: Bone marrow mesenchymal stem cells(BMSC) co-cultured with Ti-6Al-4V specimens fabricated with EBM was prepared as experimental group and the regular cells culture was employed as control. The biocompatibility was detected using CCK-8 and cytoskeleton staining. The osteogenic differentiation ability was assessed using mineralization nodule formation. A 24 mm defect was created on the right mandibular body in 12 beagles. The mandibular defects were repaired with Ti-6Al-4V scaffolds mesh fabricated by EBM. General observation, CT and histology examination was carried out to evaluated the biocompatibility of Ti-6Al-4V scaffolds in vivo. Results: CCK-8 result showed the A values of the two groups had no significant difference(P >0.05). There was no significant difference between the two groups (P>0.05). Cytoskeletal staining showed that cells were fully stretched out and grew well on T-i6Al-4V specimen. The actin fibers were arranged in parallel and stained uniformly with fluorescent. After osteogenic culture, the quantity of the nodule formation of the experimental group and control group were 5.7±0.7 and 5.1 ± 0.6, respectively(P>0.05). All animals had tolerated the surgery and healed well. CT examination showed that Ti-6Al-4V scaffolds mesh had good retention with surrounding bone and the continuity of mandible was restored. Histological examination showed that no inflammation reaction or toxity was caused in the soft tissue surrounding the scaffolds and in the liver and kidney after implantation. Ti-6Al-4V scaffolds had good retention with surrounding bone. Conclusions: Ti-6Al-4V fabricated with electron beam melting has good biocompatibility.

  9. Design analysis and performance assessment of hybrid magnetic bearings for a rotary centrifugal blood pump.

    Science.gov (United States)

    Ren, Zhaohui; Jahanmir, Said; Heshmat, Hooshang; Hunsberger, Andrew Z; Walton, James F

    2009-01-01

    A hybrid magnetic bearing system was designed for a rotary centrifugal blood pump being developed to provide long-term circulatory support for heart failure patients. This design consists of two compact bearings to suspend the rotor in five degrees-of-freedom with single axis active control. Permanent magnets are used to provide passive radial support and electromagnets to maintain axial stability of the rotor. Characteristics of the passive radial and active thrust magnetic bearing system were evaluated by the electromagnetic finite element analysis. A proportional-integral-derivative controller with force balance algorithm was implemented for closed loop control of the magnetic thrust bearing. The control position is continuously adjusted based on the electrical energy in the bearing coils, and thus passive magnetic forces carry static thrust loads to minimize the bearing current. Performance of the magnetic bearing system with associated control algorithm was evaluated at different operating conditions. The bearing current was significantly reduced with the force balance control method and the power consumption was below 0.5 W under various thrust loads. The bearing parameters predicted by the analysis were validated by the experimental data.

  10. Biochemical adaptations in middle-distance runners: an assessment of blood and anthropometric parameters

    Directory of Open Access Journals (Sweden)

    Danila Di Majo

    2014-12-01

    Full Text Available In order to understand the mechanism underlying the physiological adaptation of purely aerobic workout, we investigated the effect of 2 months of training on nine males (17-22 year-old middle distance running agonistic athletes. Blood sample was collected in the morning to analyze: hematological parameters, lipid profile, liver function enzymes [glutamate oxaloacetate transaminase, glutamate pyruvate transaminase, gamma-glutamyl transferase (γ-GT] and skeletal and myocardial markers of muscle damage [creatin kinase (CK and creatin kinase MB (CK-MB]. Endurance training, as it implies high oxygen consumption, should increase reactive oxygen species, but it has been shown that exercise leads to increased activation of antioxidant defenses. In fact, serum levels of γ-GT enzyme and total CK were not increased. On the other hand, a statistical significant reduction of CKMB has been observed. There were not variations in hematological parameters. As far as the anthropometric value is concerned, after two months of training there was a change in weight (P<0.0001. Finally, any oxidative and biological stress was highlighted in the middle distance runners but, since this is a preliminary study, it would be of interest to replicate the study on a larger sample.

  11. Assessment of the levels of DDT and DDE in soil and blood samples from Tabasco, Mexico.

    Science.gov (United States)

    Torres-Dosal, Arturo; Martinez-Salinas, Rebeca Isabel; Hernandez-Benavides, Diego; Perez-Vazquez, Francisco Javier; Ilizaliturri-Hernandez, Cesar; Perez-Maldonado, Ivan Nelinho

    2012-12-01

    In Mexico, 1,1,1-trichloro-2,2-bis(p-chlorophenyl)ethane (DDT) was used until the year 2000, principally in agriculture and anti-paludal program health campaigns. The southeastern region of Mexico was an important area of malaria, and from 1957 DDT was applied indoors every 6 months, with a coverage of 2 g/m(2). The current study was performed in Tabasco, a Mexican state located in the southeastern region of Mexico. DDT and 1,1-dichloro-2,2-bis(4-chlorophenyl)ethene (DDE) were analyzed by gas chromatography/mass spectrometry. In general, low levels were found in household outdoor samples; the levels of DDT ranged from not detectable to 0.048 mg/kg, and of DDE from 0.001 to 0.068 mg/kg. An important finding was that, in all communities where DDT in blood was analyzed, exposure to DDT was found, indicating both past and present exposure. Although the levels found in this study were lower than other studies in Mexico, there is a need to evaluate whether the people living in the study area are at risk.

  12. Assessing the Causality between Blood Pressure and Retinal Vascular Caliber through Mendelian Randomisation

    Science.gov (United States)

    Li, Ling-Jun; Liao, Jiemin; Cheung, Carol Yim-Lui; Ikram, M. Kamran; Shyong, Tai E.; Wong, Tien-Yin; Cheng, Ching-Yu

    2016-02-01

    We aimed to determine the association between blood pressure (BP) and retinal vascular caliber changes that were free from confounders and reverse causation by using Mendelian randomisation. A total of 6528 participants from a multi-ethnic cohort (Chinese, Malays, and Indians) in Singapore were included in this study. Retinal arteriolar and venular caliber was measured by a semi-automated computer program. Genotyping was done using Illumina 610-quad chips. Meta-analysis of association between BP, and retinal arteriolar and venular caliber across three ethnic groups was performed both in conventional linear regression and Mendelian randomisation framework with a genetic risk score of BP as an instrumental variable. In multiple linear regression models, each 10 mm Hg increase in systolic BP, diastolic BP, and mean arterial BP (MAP) was associated with significant decreases in retinal arteriolar caliber of a 1.4, 3.0, and 2.6 μm, and significant decreases in retinal venular caliber of a 0.6, 0.7, and 0.9 μm, respectively. In a Mendelian randomisation model, only associations between DBP and MAP and retinal arteriolar narrowing remained yet its significance was greatly reduced. Our data showed weak evidence of a causal relationship between elevated BP and retinal arteriolar narrowing.

  13. Diagnostic tool for red blood cell membrane disorders: Assessment of a new generation ektacytometer.

    Science.gov (United States)

    Da Costa, Lydie; Suner, Ludovic; Galimand, Julie; Bonnel, Amandine; Pascreau, Tiffany; Couque, Nathalie; Fenneteau, Odile; Mohandas, Narla

    2016-01-01

    Inherited red blood cell (RBC) membrane disorders, such as hereditary spherocytosis, elliptocytosis and hereditary ovalocytosis, result from mutations in genes encoding various RBC membrane and skeletal proteins. The RBC membrane, a composite structure composed of a lipid bilayer linked to a spectrin/actin-based membrane skeleton, confers upon the RBC unique features of deformability and mechanical stability. The disease severity is primarily dependent on the extent of membrane surface area loss. RBC membrane disorders can be readily diagnosed by various laboratory approaches that include RBC cytology, flow cytometry, ektacytometry, electrophoresis of RBC membrane proteins and genetics. The reference technique for diagnosis of RBC membrane disorders is the osmotic gradient ektacytometry. However, in spite of its recognition as the reference technique, this technique is rarely used as a routine diagnosis tool for RBC membrane disorders due to its limited availability. This may soon change as a new generation of ektacytometer has been recently engineered. In this review, we describe the workflow of the samples shipped to our Hematology laboratory for RBC membrane disorder analysis and the data obtained for a large cohort of French patients presenting with RBC membrane disorders using a newly available version of the ektacytomer.

  14. Noncontact diffuse optical assessment of blood flow changes in head and neck free tissue transfer flaps

    Science.gov (United States)

    Huang, Chong; Radabaugh, Jeffrey P.; Aouad, Rony K.; Lin, Yu; Gal, Thomas J.; Patel, Amit B.; Valentino, Joseph; Shang, Yu; Yu, Guoqiang

    2015-07-01

    Knowledge of tissue blood flow (BF) changes after free tissue transfer may enable surgeons to predict the failure of flap thrombosis at an early stage. This study used our recently developed noncontact diffuse correlation spectroscopy to monitor dynamic BF changes in free flaps without getting in contact with the targeted tissue. Eight free flaps were elevated in patients with head and neck cancer; one of the flaps failed. Multiple BF measurements probing the transferred tissue were performed during and post the surgical operation. Postoperative BF values were normalized to the intraoperative baselines (assigning "1") for the calculation of relative BF change (rBF). The rBF changes over the seven successful flaps were 1.89±0.15, 2.26±0.13, and 2.43±0.13 (mean±standard error), respectively, on postoperative days 2, 4, and 7. These postoperative values were significantly higher than the intraoperative baseline values (pflap vascularity after the tissue transfer. By contrast, rBF changes observed from the unsuccessful flaps were 1.14 and 1.34, respectively, on postoperative days 2 and 4, indicating less flow recovery. Measurement of BF recovery after flap anastomosis holds the potential to act early to salvage ischemic flaps.

  15. Time-dependent biodistribution, clearance and biocompatibility of magnetic fibrin nanoparticles: an in vivo study

    Science.gov (United States)

    Prabu, Periyathambi; Vedakumari, Weslen S.; Sastry, Thotapalli P.

    2015-05-01

    Recently, bioretention and toxicity of injected nanoparticles in the body has drawn much attention in biomedical research. In the present study, 5 mg Fe per kg body weight of magnetic fibrin nanoparticles (MFNPs) were injected into mice intravenously and investigated for their blood clearance profile, biodistribution, haematology and pathology studies for a time period of 28 days. Moderately long circulation of MFNPs in blood was observed with probable degradation and excretion into the bloodstream via monoatomic iron forms. Inductively coupled plasma optical emission spectrometry (ICP-OES) and Prussian blue staining results showed increased accumulation of MFNPs in the liver, followed by spleen and other organs. Body weight, spleen/thymus indexes, haematology, serum biochemistry and histopathology studies demonstrated that MFNPs were biocompatible. These results suggest the feasibility of using MFNPs for drug delivery and imaging applications.

  16. [Study on biocompatibility of titanium alloys].

    Science.gov (United States)

    Kodama, T

    1989-06-01

    The biocompatibility of two different titanium alloys, Ti-6Al-4V ELI and Ti-5Al-2, 5Fe, and pure titanium were evaluated. The results were as follows: 1) Titanium alloys were implanted into the dorsal subcutaneous tissues of the Hartley guinea-pig for 12 weeks, immersed in calf serum or in Ringer's solution for 8 weeks. The surface changes of the titanium alloys were observed by SEM and the chemical composition was analyzed by XMA. No evident surface changes were found. 2) Three hundred mg, 200 mg and 100 mg of the powders of the tested materials were immersed in 2ml of Eagle's MEM, incubated for 1-7 days, 8-21 days and 22-70 days at 37 C degrees. The amount of metallic elements dissolved in the solutions was measured by ICP and AAS. The detected corrosion rates of V and Al contained in the solution, in which Ti-6Al-4V ELI 100 mg was immersed for 1-7 days, were 194.3 +/- 17.6 and 73.0 +/- 28, 1 pg/mg alloy/day, respectively. V was released more than Al. The amount of Ti was below the detectable limit. The solution Ti-5Al-2.5 Fe 100 mg immersed for 1-7 days contained 31.9 +/- 34.4 pg/mg alloy/day Fe and 25.7 +/- 6.3 pg/mg alloy/day Al. Only in the solution 300 mg immersed for 1-7 days was Ti detected at 1.4 pg/mg alloy/day. 3) By the bacterial mutation assay of Salmonella typhimurium TA 98, Salmonella typhimurium TA 100 and Escherichia coli WP2 uvrA, the solutions, in which the tested materials were immersed, were not found to be mutagenic. 4) By the UDS assay, the grain counts on autoradiography with the solutions, in which the tested materials were immersed, were not greater than the negative control. The results suggest an excellent corrosion resistance of the titanium alloys. Mutagenicity was negative by these mutation assays, indicating that the tested alloys and pure titanium are safe for humans and animals.

  17. Myocardial blood flow assessment with {sup 82}rubidium-PET imaging in patients with left bundle branch block

    Energy Technology Data Exchange (ETDEWEB)

    Falcao, Andrea; Chalela, William; Giorgi, Maria Clementina; Imada, Rodrigo; Soares Junior, Jose; Do Val, Renata; Oliveira, Marco Antonio; Izaki, Marisa; Kalil Filho, Roberto; Meneghetti, Jose C., E-mail: andrea.falcao@incor.usp.br [Universidade de Sao Paulo (InCor/USP), Sao Paulo, SP (Brazil). Hospital das Clinicas. Instituto do Coracao

    2015-11-15

    Objectives: Perfusion abnormalities are frequently seen in Single Photon Emission Computed Tomography (SPECT) when a left bundle branch block is present. A few studies have shown decreased coronary flow reserve in the left anterior descending territory, regardless of the presence of coronary artery disease. Objective: we sought to investigate rubidium-82 ({sup 82}Rb) positron emission tomography imaging in the assessment of myocardial blood flow and coronary flow reserve in patients with left bundle branch block. Methods: thirty-eight patients with left bundle branch block (GI), median age 63.5 years, 22 (58%) female, 12 with coronary artery disease (≥70%; GI-A) and 26 with no evidence of significant coronary artery disease (GI-B), underwent rest-dipyridamole stress {sup 82}Rb-positron emission tomography with absolute quantitative flow measurements using Cedars-Sinai software (mL/min/g). The relative myocardial perfusion and left ventricular ejection fraction were assessed in 17 segments. These parameters were compared with those obtained from 30 patients with normal {sup 82}Rb-positron emission tomography studies and without left bundle branch block (GII). Results: stress myocardial blood flow and coronary flow reserve were significantly lower in GI than in GII (p>0.05). The comparison of coronary flow reserve between GI-A and GI-B showed that it was different from the global coronary flow reserve (p<0.05) and the stress flow was significantly lower in the anterior than in the septal wall for both groups. Perfusion abnormalities were more prevalent in GI-A (p=0.06) and the left ventricular ejection fraction was not different between GI-A and GI-B, whereas it was lower in GI than in GII (p<0.001). Conclusion: the data confirm that patients with left bundle branch block had decreased myocardial blood flow and coronary flow reserve and coronary flow reserve assessed by {sup 82}Rb-positron emission tomography imaging may be useful in identifying coronary artery

  18. Dynamic contrast-enhanced MRI assessment of hyperemic fractional microvascular blood plasma volume in peripheral arterial disease: initial findings.

    Directory of Open Access Journals (Sweden)

    Bas Versluis

    Full Text Available OBJECTIVES: The aim of the current study was to describe a method that assesses the hyperemic microvascular blood plasma volume of the calf musculature. The reversibly albumin binding contrast agent gadofosveset was used in dynamic contrast-enhanced magnetic resonance imaging (DCE MRI to assess the microvascular status in patients with peripheral arterial disease (PAD and healthy controls. In addition, the reproducibility of this method in healthy controls was determined. MATERIALS AND METHODS: Ten PAD patients with intermittent claudication and 10 healthy control subjects were included. Patients underwent contrast-enhanced MR angiography of the peripheral arteries, followed by one DCE MRI examination of the musculature of the calf. Healthy control subjects were examined twice on different days to determine normative values and the interreader and interscan reproducibility of the technique. The MRI protocol comprised dynamic imaging of contrast agent wash-in under reactive hyperemia conditions of the calf musculature. Using pharmacokinetic modeling the hyperemic fractional microvascular blood plasma volume (V(p, unit: % of the anterior tibial, gastrocnemius and soleus muscles was calculated. RESULTS: V(p was significantly lower for all muscle groups in PAD patients (4.3±1.6%, 5.0±3.3% and 6.1±3.6% for anterior tibial, gastrocnemius and soleus muscles, respectively compared to healthy control subjects (9.1±2.0%, 8.9±1.9% and 9.3±2.1%. Differences in V(p between muscle groups were not significant. The coefficient of variation of V(p varied from 10-14% and 11-16% at interscan and interreader level, respectively. CONCLUSIONS: Using DCE MRI after contrast-enhanced MR angiography with gadofosveset enables reproducible assessment of hyperemic fractional microvascular blood plasma volume of the calf musculature. V(p was lower in PAD patients than in healthy controls, which reflects a promising functional (hemodynamic biomarker for the

  19. Impact of antihypertensive combination and monotreatments on blood pressure variability: assessment by old and new indices. Data from a large ambulatory blood pressure monitoring database.

    LENUS (Irish Health Repository)

    Parati, Gianfranco

    2014-06-01

    High 24-h ambulatory blood pressure (ABP) variability is associated with poor cardiovascular outcomes. We analysed a large ABP monitoring database containing data from hypertensive patients treated with telmisartan\\/amlodipine combination or various monotherapies with the aim of quantifying the 24-h distribution of blood pressure (BP) reduction by treatment through the smoothness index and of developing and testing a new treatment-on-variability index (TOVI) to quantify the effects of treatment on both mean BP and BP variability.

  20. Benzene exposure, assessed by urinary trans,trans-muconic acid, in urban children with elevated blood lead levels

    Energy Technology Data Exchange (ETDEWEB)

    Weaver, V.M.; Fitzwilliam, A.; Peters, H.L.; Groopman, J.D. [Johns Hopkins Univ. School of Hygiene and Public Health, Baltimore, MD (United States)] [and others

    1996-03-01

    A pilot study was performed to evaluate the feasibility of using trans, trans-muconic acid (MA) as a biomarker of environmental benzene exposure. A secondary aim was to provide data on the extent of exposure to selected toxicants in a unique population consisting of inner-city children who were already overexposed to one urban hazard, lead. Potential sources of benzene were assessed by a questionnaire. Exposure biomarkers included urinary MA and cotinine and blood lead. Mean MA was 176.6 {plus_minus} 341.7 ng/mg creatinine in the 79 children who participated. A wide range of values was found with as many as 10.1%, depending on the comparison study, above the highest levels reported in adults not exposed by occupation. Mean MA was increased in children evaluated in the afternoon compared to morning, those at or above the median for time spent playing near the street, and those studied in the first half of the investigation. MA levels were not associated with blood lead or, consistently, with either questionnaire environmental tobacco smoke (ETS) data or cotinine. As expected, the mean blood lead level was elevated (23.6 {mu}g/dl). Mean cotinine was also increased at 79.2 ng/mg creatinine. We conclude that the use of MA as a biomarker for environmental benzene exposure is feasible since it was detectable in 72% of subjects with a wide range of values present. In future studies, correlation of MA with personal air sampling in environmental exposure will be essential to fully interpret the significance of these findings. In addition, these inner-city children comprise a high risk group for exposure to environmental toxicants including ETS, lead, and probably benzene, based on questionnaire sources and its presence in ETS. 22 refs., 5 figs., 4 tabs.

  1. Assessing determinants of maternal blood concentrations for persistent organic pollutants and metals in the eastern and western Canadian Arctic.

    Science.gov (United States)

    Curren, Meredith S; Liang, Chun Lei; Davis, Karelyn; Kandola, Kami; Brewster, Janet; Potyrala, Mary; Chan, Hing Man

    2015-09-15

    Aboriginal peoples in the Canadian Arctic are exposed to persistent organic pollutants (POPs) and metals mainly through their consumption of a traditional diet of wildlife items. Recent studies indicate that many human chemical levels have decreased in the north, likely due to a combination of reduced global chemical emissions, dietary shifts, and risk mitigation efforts by local health authorities. Body burdens for chemicals in mothers can be further offset by breastfeeding, parity, and other maternal characteristics. We have assessed the impact of several dietary and maternal covariates following a decade of awareness of the contaminant issue in northern Canada, by performing multiple stepwise linear regression analyses from blood concentrations and demographic variables for 176 mothers recruited from Nunavut and the Northwest Territories during the period 2005-2007. A significant aboriginal group effect was observed for the modeled chemicals, except for lead and cadmium, after adjusting for covariates. Further, blood concentrations for POPs and metals were significantly associated with at least one covariate of older age, fewer months spent breastfeeding, more frequent eating of traditional foods, or smoking during pregnancy. Cadmium had the highest explained variance (72.5%) from just two significant covariates (current smoking status and parity). Although Inuit participants from the Northwest Territories consumed more traditional foods in general, Inuit participants from coastal communities in Nunavut continued to demonstrate higher adjusted blood concentrations for POPs and metals examined here. While this is due in part to a higher prevalence of marine mammals in the eastern Arctic diet, it is possible that other aboriginal group effects unrelated to diet may also contribute to elevated chemical body burdens in Canadian Arctic populations. Crown Copyright © 2015. Published by Elsevier B.V. All rights reserved.

  2. Assessment of the cytokine profile in peripheral blood mononuclear cells of naturally Sarcoptes scabiei var. canis infested dogs.

    Science.gov (United States)

    Singh, Shanker K; Dimri, Umesh; Sharma, Bhaskar; Saxena, Meeta; Kumari, Priyambada

    2014-12-15

    The mechanism of cytokine secretion from T lymphocytes plays an important role in the immune response of dogs and parasitic skin infestations. Assessment of the cytokine profile of naturally S. scabiei var. canis infested dogs could augment understanding of the pathobiology of canine sarcoptic mange. Therefore, the present study examined the cytokines in peripheral blood mononuclear cells of dogs suffering from sarcoptic mange. Thirteen dogs naturally infected with sarcoptic mange participated in the study. The dogs were found positive for S. scabiei var. canis mites in skin scraping examinations and revealed at least three clinical inclusion criteria. Another five clinically healthy dogs were kept as healthy controls. Peripheral blood mononuclear cells were isolated from heparinized blood samples and used for extraction of mRNA. Further, cDNA was synthesized by using 1 mg of mRNA by reverse transcription using oligonucleotide primers. Relative levels of cytokine expression were compared with normalized glyceraldehyde-3-phosphate dehydrogenase (GAPDH) transcripts. The levels of interleukin-4, interleukin-5 and transforming growth factor beta (TGF-β) mRNA expression in dogs with sarcoptic mange were significantly higher (P ≤ 0.01), whereas the level of tumor necrosis factor alpha (TNF-α) was significantly lower (P ≤ 0.01) in comparison with the healthy dogs. No remarkable difference was seen for interleukin-2 mRNA expression between these animals. An overproduction IL-4 and IL-5 might be involved in immuno-pathogenesis of canine sarcoptic mange. S. scabiei var. canis mites possibly induce an overproduction of TGF-β and reduced expression of TNF-α and thus could be conferring the immune suppression of infested dogs.

  3. Venous vs arterial blood gases in the assessment of patients presenting with an exacerbation of chronic obstructive pulmonary disease.

    Science.gov (United States)

    McCanny, Peter; Bennett, Kath; Staunton, Paul; McMahon, Geraldine

    2012-07-01

    The purpose of this study was to investigate the clinical correlation between arterial and venous blood gas (VBG) values in patients presenting to the emergency department (ED) with acute exacerbation of chronic obstructive pulmonary disease. A prospective study of patients with chronic obstructive pulmonary disease presenting to the ED with acute ventilatory compromise was done. Patients were included if their attending physician considered arterial blood gas sampling important in their initial assessment. Data from arterial and venous samples were compared using Spearman correlation and bias plot (Bland-Altman) methods. Ninety-four patients were enrolled in the study. Eighty-nine patients had complete data sets for analysis. Arterial hypercarbia was present in 30 patients (33.7%; range, 51-140.19 mm Hg). All cases of arterial hypercarbia were detected using VBG sampling when a screening cutoff of 45 mm Hg was applied (sensitivity, 100%; 95% confidence interval, 88.7%-100% and specificity, 34%; 95% confidence interval, 23.1%-46.6%). Bias plot revealed moderate agreement between arterial and venous Pco(2) with an average difference of 8.6 mm Hg and 95% limits of agreement of -7.84 to 25.05 mm Hg. For pH, mean difference between each group was 0.039 (range, -0.12 to 0.03). Linear regression analysis for pH demonstrated very close equivalence with a regression coefficient of 0.955, and Spearman correlation showed significant correlation of 0.826 (P = .001). Venous pH and HCO(3) values show excellent correlation with arterial values. Using a previously validated screening cutoff of 45 mm Hg, venous CO(2) has 100% sensitivity in detecting arterial hypercarbia. There is insufficient agreement between venous and arterial CO(2) for VBG to replace arterial blood gas in determining the degree of hypercarbia. Copyright © 2012 Elsevier Inc. All rights reserved.

  4. Assessing determinants of maternal blood concentrations for persistent organic pollutants and metals in the eastern and western Canadian Arctic

    Energy Technology Data Exchange (ETDEWEB)

    Curren, Meredith S., E-mail: meredith.curren@hc-sc.gc.ca [Chemicals Surveillance Bureau, Healthy Environments and Consumer Safety Branch, Health Canada, 269 Laurier Avenue West, Ottawa, Ontario (Canada); Liang, Chun Lei, E-mail: chun.lei.liang@hc-sc.gc.ca [Environmental Health Science and Research Bureau, Healthy Environments and Consumer Safety Branch, Health Canada, 50 Columbine Driveway, Tunney' s Pasture, Ottawa, Ontario (Canada); Davis, Karelyn, E-mail: karelyn.davis@hc-sc.gc.ca [Environmental Health Science and Research Bureau, Healthy Environments and Consumer Safety Branch, Health Canada, 50 Columbine Driveway, Tunney' s Pasture, Ottawa, Ontario (Canada); Kandola, Kami, E-mail: Kami_Kandola@gov.nt.ca [Government of the Northwest Territories, Yellowknife, Northwest Territories (Canada); Brewster, Janet, E-mail: jbrewster@gov.nu.ca [Government of Nunavut, Iqaluit, Nunavut (Canada); Potyrala, Mary, E-mail: mary_potyrala@yahoo.ca [Government of Nunavut, Iqaluit, Nunavut (Canada); Chan, Hing Man, E-mail: laurie.chan@uottawa.ca [Center for Advanced Research in Environmental Genomics, University of Ottawa, 20 Marie-Curie, Ottawa, Ontario (Canada)

    2015-09-15

    Aboriginal peoples in the Canadian Arctic are exposed to persistent organic pollutants (POPs) and metals mainly through their consumption of a traditional diet of wildlife items. Recent studies indicate that many human chemical levels have decreased in the north, likely due to a combination of reduced global chemical emissions, dietary shifts, and risk mitigation efforts by local health authorities. Body burdens for chemicals in mothers can be further offset by breastfeeding, parity, and other maternal characteristics. We have assessed the impact of several dietary and maternal covariates following a decade of awareness of the contaminant issue in northern Canada, by performing multiple stepwise linear regression analyses from blood concentrations and demographic variables for 176 mothers recruited from Nunavut and the Northwest Territories during the period 2005–2007. A significant aboriginal group effect was observed for the modeled chemicals, except for lead and cadmium, after adjusting for covariates. Further, blood concentrations for POPs and metals were significantly associated with at least one covariate of older age, fewer months spent breastfeeding, more frequent eating of traditional foods, or smoking during pregnancy. Cadmium had the highest explained variance (72.5%) from just two significant covariates (current smoking status and parity). Although Inuit participants from the Northwest Territories consumed more traditional foods in general, Inuit participants from coastal communities in Nunavut continued to demonstrate higher adjusted blood concentrations for POPs and metals examined here. While this is due in part to a higher prevalence of marine mammals in the eastern Arctic diet, it is possible that other aboriginal group effects unrelated to diet may also contribute to elevated chemical body burdens in Canadian Arctic populations. - Highlights: • In 2005–07, younger age was related to lower levels of chemicals in northern Canada. • Eastern

  5. No association between blood telomere length and longitudinally assessed diet or adiposity in a young adult Filipino population.

    Science.gov (United States)

    Bethancourt, Hilary J; Kratz, Mario; Beresford, Shirley A A; Hayes, M Geoffrey; Kuzawa, Christopher W; Duazo, Paulita L; Borja, Judith B; Eisenberg, Daniel T A

    2017-02-01

    Telomeres, DNA-protein structures that cap and protect chromosomes, are thought to shorten more rapidly when exposed to chronic inflammation and oxidative stress. Diet and nutritional status may be a source of inflammation and oxidative stress. However, relationships between telomere length (TL) and diet or adiposity have primarily been studied cross-sectionally among older, overweight/obese populations and yielded inconsistent results. Little is known about the relationship between diet or body composition and TL among younger, low- to normal-weight populations. It also remains unclear how cumulative exposure to a specific diet or body composition during the years of growth and development, when telomere attrition is most rapid, may be related to TL in adulthood. In a sample of 1459 young adult Filipinos, we assessed the relationship between blood TL at ages 20.8-22.5 and measures of BMI z-score, waist circumference, and diet collected between the ages of 8.5 and 22.5. TL was measured using monochrome multiplex quantitative PCR, and diet was measured using multiple 24-h recalls. We found no associations between blood TL and any of the measures of adiposity or between blood TL and the seven dietary factors examined: processed meats, fried/grilled meats and fish, non-fried fish, coconut oil, fruits and vegetables, bread and bread products, and sugar-sweetened beverages. Considering the inconsistencies in the literature and our null results, small differences in body composition and consumption of any single pro- or anti-inflammatory dietary component may not by themselves have a meaningful impact on telomere integrity, or the impact may differ across distinct ecological circumstances.

  6. Blood concentrations and risk assessment of persistent organochlorine compounds in newborn boys in Turkey. A pilot study.

    Science.gov (United States)

    Ulutaş, Onur Kenan; Çok, İsmet; Darendeliler, Feyza; Aydin, Banu; Çoban, Asuman; Henkelmann, Bernhard; Schramm, Karl-Werner

    2015-12-01

    Even early life in utero cannot provide a safe place for newborns. The first acquaintance with chemicals takes place in utero and/or with mother's milk after delivery. Besides legislations and bans to persistent organic pollutants (POPs), these chemicals are still affecting the general population especially the children as they are one of the populations most susceptible to chemicals, and also the health problems may arise in the future. Our objective is to collect the first data in newborns in Turkey to determine baseline levels of POPs in the general population and estimate the potential cancer risk related to exposure. Twenty-nine organochlorine pesticides (OCPs) and 18 polychlorinated biphenyl (PCB) congeners in blood samples of newborn boys (0-1 month old) who were born in İstanbul, Turkey, in 2010-2012 were evaluated with high-resolution gas chromatography-high-resolution mass spectrometry (HRGC/HRMS). Results for analyzed chlorinated compounds are as follows: hexachlorocyclohexane (ΣHCH) 1828 ± 3650 pg/g lipid, dichlorodiphenyltrichloroethane (ΣDDT) 10,000 ± 15,398 pg/g lipid, and ΣPCB 1068 ± 1823 pg/g lipid. 4,4'-DDT, 4,4'-dichlorodiphenyldichloroethylene (4,4'-DDE), hexachlorobenzene, and PCB 138 and 153 are the major contaminants. New POPs as lindane 61 ± 268 pg/g lipid, pentachlorobenzene 13 ± 74 pg/g lipid, and endosulfan 29 ± 106 pg/g lipid are also detected in blood. Estimated total risk for lifetime PCB exposure is less than 1 × 10(-5), an acceptable risk. Blood concentration levels will be important base data in the assessment of health concerns of newborns as well as for studies about how endocrine disruptors affect humans.

  7. Assessment of the in vivo genotoxicity of isomers of dinitrotoluene using the alkaline Comet and peripheral blood micronucleus assays.

    Science.gov (United States)

    Lent, Emily May; Crouse, Lee C B; Quinn, Michael J; Wallace, Shannon M

    2012-02-18

    Dinitrotoluene (DNT) is a nitroaromatic explosive that exists as six isomers; two major isomers (2,4- and 2,6-DNT) and four minor isomers (2,3-, 2,5-, 3,4-, and 3,5-DNT). DNT has been found in soil, surface water, and groundwater near ammunition production plants. The major isomers of DNT are classified as "likely to cause cancer in humans."In vitro studies have provided conflicting data regarding the genotoxicity of the minor isomers. Studies indicate that metabolism in the gut and liver are necessary to convert DNT to genotoxic compounds. As such, in the present study the genotoxicity of isomers of DNT was assessed using two in vivo genotoxicity assays. The Comet assay was used to detect DNA damage in liver cells from male Sprague-Dawley rats following oral exposure (14-day) to individual isomers of DNT. The micronucleus assay was conducted using flow cytometric analysis to detect chromosomal damage in peripheral blood. Treatment with 2,3-, 3,4-, 2,4-, 2,5- and 3,5-DNT did not induce DNA damage in liver cells or increase the frequency of micronucleated reticulocytes (MN-RET) in peripheral blood at the doses tested. Treatment with 2,6-DNT induced DNA damage in liver tissue at all doses tested, but did not increase the frequency of micronucleated reticulocytes (MN-RET) in peripheral blood. Thus, 2,4-DNT and the minor isomers were not genotoxic under these test conditions, while 2,6-DNT was genotoxic in the target tissue, the liver. These results support previous research which indicated that the hepatocarcinogenicity of technical grade DNT (TG-DNT) could be attributed to the 2,6-DNT isomer. Published by Elsevier B.V.

  8. Assessment of relationship between physical activity volume and blood lipids concentration in Hamedanian middle age men

    Directory of Open Access Journals (Sweden)

    Majid Jalili

    2012-06-01

    Full Text Available Background: Inactivity is a leading contributor to chronic health problems. Physical activity (PA is an important element in maintaining the health and functional ability in the population and has favorable effects on lipid profile in adults. Here, we examined the effects of pedometer-based PA (step/day in healthy middle age men. Methods: Height, weight, body mass index (BMI, and daily oxygen consumption (VO2peak were measured in 27 active and sedentary healthy middle aged men (40-65 yr. Subjects wore a pedometer throughout the day for three consecutive weeks, and average steps per day (physical activity volume were measured. Fasting serum concentrations of total cholesterol (TC, triglyceride (TG, high density lipoprotein-cholesterol (HDL-C, and low density lipoprotein-cholesterol (LDL-C were measured. Results: Mean of Daily steps in the Active group (AG (12632±3957 steps/day was significantly higher than sedentary group (SG (5347±1631step/day (p0.05. A significant correlation was found between average steps per day and TG (-0.424, P = 0.027 TC (-0.389, P = 0.045 TC/HDL-C (-0.469 P = 0.014 HDL-C/LDL-C (-0.390 P = 0.044 and Daily Oxygen Consumption (-0.853 P = 0.000. Conclusion: It seems that, healthy middle-aged men, who have more ambulatory activity (average of 12,500 step/day, have significantly better blood lipids’ profile.

  9. Subjective food hypersensitivity: assessment of enterochromaffin cell markers in blood and gut lavage fluid

    Directory of Open Access Journals (Sweden)

    Gregersen K

    2011-08-01

    Full Text Available Kine Gregersen1,2, Jørgen Valeur1,3, Kristine Lillestøl1,3, Livar Frøyland2, Pedro Araujo2, Gülen Arslan Lied1,3, Arnold Berstad1,31Institute of Medicine, University of Bergen, 2National Institute of Nutrition and Seafood Research; 3Department of Medicine, Section for Gastroenterology, Haukeland University Hospital, Bergen, NorwayBackground: Food hypersensitivity is commonly suspected, but seldom verified. Patients with subjective food hypersensitivity suffer from both intestinal and extraintestinal health complaints. Abnormalities of the enterochromaffin cells may play a role in the pathogenesis. The aim of this study was to investigate enterochromaffin cell function in patients with subjective food hypersensitivity by measuring serum chromogranin A (CgA and 5-hydroxytryptamine (5-HT, serotonin in gut lavage fluid.Methods: Sixty-nine patients with subjective food hypersensitivity were examined. Twenty-three patients with inflammatory bowel disease and 35 healthy volunteers were included as comparison groups. CgA was measured in serum by enzyme-linked immunosorbent assay. Gut lavage fluid was obtained by administering 2 L of polyethylene glycol solution intraduodenally. The first clear fluid passed per rectum was collected and 5-HT was analyzed by liquid chromatography tandem mass spectrometry.Results: Serum levels of CgA were significantly lower in patients with subjective food hypersensitivity than in healthy controls (P = 0.04. No differences were found in 5-HT levels in gut lavage fluid between patients with subjective food hypersensitivity and the control groups. There was no correlation between serum CgA and gut lavage 5-HT.Conclusion: Decreased blood levels of CgA suggest neuroendocrine alterations in patients with subjective food hypersensitivity. However, 5-HT levels in gut lavage fluid were normal.Keywords: food hypersensitivity, chromogranin A, serotonin, gut lavage fluid, liquid chromatography

  10. Assessment of aerobic capacity through blood and ventilatory responses in four different ergometers

    Directory of Open Access Journals (Sweden)

    Alessandro Moura Zagatto

    2013-04-01

    Full Text Available The objective of the study was to compare intensities of respiratory compensation point (RCP,anaerobic threshold at onset blood lactate accumulation (OBLA3,5, and anaerobic threshold at lactate abrupt increase (AnTLAC determined in four different ergometers. Hence, eleven table tennis players (19±1 years performed graded exercise tests on cycle ergometer, arm cranking ergometer, treadmill and specific table tennis test. The respiratory response and lactatemia were measured during the tests. We did not find significant diferences among RCP, AnTLAC and OBLA3,5 in arm cranking ergometer (63.4±4.8W, 66.9±4.5W and 64.5±6.1W, respectively, treadmill (11.4±0.4 km.h-1, 11.3±0.3 km.h-1 and 11.1±0.3 km.h-1, respectively, and specific table tennis test (40.5±1.8 bolas.min-1, 42.6±3.6bolas.min-1 and 42.8±5.6bolas.min-1,respectively. However, the OBLA 3,5 (131.9±6.6W was significantly lower than RCP (149.3±4.9W and AnTLAC (149.3±4.7W in the cycle ergometer. Strong and significant correlation coefficients were found in the specific test for all methods (r range 0.83 to 0.95, in arm cranking ergometer between RCP and OBLA 3,5 (r=0.78, and on treadmill running between OBLA3,5 and AnTLAC (r=0.76.Therefore, we conclude that RCP, OBLA3,5 and AnTLAC seem to correspond to the same physiological phenomenon, mostly during specific table tennis test.

  11. Assessment of the interaction of Portland cement-based materials with blood and tissue fluids using an animal model

    Science.gov (United States)

    Schembri Wismayer, P.; Lung, C. Y. K.; Rappa, F.; Cappello, F.; Camilleri, J.

    2016-01-01

    Portland cement used in the construction industry improves its properties when wet. Since most dental materials are used in a moist environment, Portland cement has been developed for use in dentistry. The first generation material is mineral trioxide aggregate (MTA), used in surgical procedures, thus in contact with blood. The aim of this study was to compare the setting of MTA in vitro and in vivo in contact with blood by subcutaneous implantation in rats. The tissue reaction to the material was also investigated. ProRoot MTA (Dentsply) was implanted in the subcutaneous tissues of Sprague-Dawley rats in opposite flanks and left in situ for 3 months. Furthermore the material was also stored in physiological solution in vitro. At the end of the incubation time, tissue histology and material characterization were performed. Surface assessment showed the formation of calcium carbonate for both environments. The bismuth was evident in the tissues thus showing heavy element contamination of the animal specimen. The tissue histology showed a chronic inflammatory cell infiltrate associated with the MTA. MTA interacts with the host tissues and causes a chronic inflammatory reaction when implanted subcutaneously. Hydration in vivo proceeds similarly to the in vitro model with some differences particularly in the bismuth oxide leaching patterns. PMID:27683067

  12. Assessment of gene expression in peripheral blood using RNAseq before and after weight restoration in anorexia nervosa.

    Science.gov (United States)

    Kim, Yunjung; Trace, Sara E; Crowley, James J; Brownley, Kimberly A; Hamer, Robert M; Pisetsky, David S; Sullivan, Patrick F; Bulik, Cynthia M

    2013-11-30

    We examined gene expression in the blood of six females with anorexia nervosa (AN) before and after weight restoration using RNAseq. AN cases (aged 19-39) completed clinical assessments and had blood drawn for RNA at hospital admission (T1,<~75% ideal body weight, IBW) and again at discharge (T2,≥ ~ 85% IBW). To examine the relationship between weight restoration and differential gene expression, normalized gene expression levels were analyzed using a paired design. We found 564 genes whose expression was nominally significantly different following weight restoration (p<0.01, 231 increased and 333 decreased). With a more stringent significance threshold (false discovery rate q<0.05), 67 genes met criteria for differential expression. Of the top 20 genes, CYP11A1, C16orf11, LINC00235, and CPA3 were down-regulated more than two-fold after weight restoration while multiple olfactory receptor genes (OR52J3, OR51L1, OR51A4, and OR51A2) were up-regulated more than two-fold after weight restoration. Pathway analysis revealed up-regulation of two broad pathways with largely overlapping genes, one related to protein secretion and signaling and the other associated with defense response to bacterial regulation. Although results are preliminary secondary to a small sample size, these data provide initial evidence of transcriptional alterations during weight restoration in AN. © 2013 Elsevier Ireland Ltd. All rights reserved.

  13. Assessment of DDT, DDE, and 1-hydroxypyrene levels in blood and urine samples in children from Chiapas Mexico.

    Science.gov (United States)

    Martínez-salinas, Rebeca I; Pérez-Maldonado, Iván N; Batres-Esquivel, Lilia E; Flores-Ramírez, Rogelio; Díaz-Barriga, Fernando

    2011-08-01

    The aim of this study was assess co-exposure to DDT, DDE (main DDT metabolite), and PAHs (1-hydroxypyrene) in areas where biomass is used to cook and to heat homes and where DDT was used to combat malaria transmission. During 2009, we analyzed a total of 190 blood and urine samples from children living in six communities in Mexico. Quantitative analyses of DDT and DDE were performed using gas chromatography coupled with mass spectrometry. Analyses of 1-hydroxypyrene were performed by HPLC using a fluorescence detector. In this work, we found high levels of DDT and its principal metabolite (DDE) in the blood of children living in four communities in Chiapas located in the southeastern region of Mexico (range,

  14. Assessment of red blood cell deformability in type 2 diabetes mellitus and diabetic retinopathy by dual optical tweezers stretching technique.

    Science.gov (United States)

    Agrawal, Rupesh; Smart, Thomas; Nobre-Cardoso, João; Richards, Christopher; Bhatnagar, Rhythm; Tufail, Adnan; Shima, David; Jones, Phil H; Pavesio, Carlos

    2016-03-15

    A pilot cross sectional study was conducted to investigate the role of red blood cells (RBC) deformability in type 2 diabetes mellitus (T2DM) without and with diabetic retinopathy (DR) using a dual optical tweezers stretching technique. A dual optical tweezers was made by splitting and recombining a single Nd:YAG laser beam. RBCs were trapped directly (i.e., without microbead handles) in the dual optical tweezers where they were observed to adopt a "side-on" orientation. RBC initial and final lengths after stretching were measured by digital video microscopy, and a Deformability index (DI) calculated. Blood from 8 healthy controls, 5 T2DM and 7 DR patients with respective mean age of 52.4 yrs, 51.6 yrs and 52 yrs was analysed. Initial average length of RBCs for control group was 8.45 ± 0.25 μm, 8.68 ± 0.49 μm for DM RBCs and 8.82 ± 0.32 μm for DR RBCs (p optical tweezers method can hence be reliably used to assess RBC deformability.

  15. PATIENT-SPECIFIC BLOOD DYNAMIC SIMULATIONS IN ASSESSING ENDOVASCULAR OCCLUSION OF INTRACRANIAL ANEURYSMS

    Institute of Scientific and Technical Information of China (English)

    CHEN Jia-liang; WANG Sheng-zhang; DING Guang-hong; YANG Xin-jian; LI Hai-yun

    2009-01-01

    According to recent studies, there are various potential predictors for surgical outcome for cerebral aneurysms. An accurate surgical outcome assessment would help make better-informed decisions and avoid the risk of rebleeding. It is well known that hemodynamic factors play an important role in the pathogenesis and treatment of intracranial aneurysms. In this article, a computational fluid dynamic analysis is applied to one patient-specific model of the cerebral aneurysm located at the tip of basilar artery, by which the differences of hemodynamic parameters before and after endovascular treatment may be evaluated. Based on the model, we show that the flow behavior near the neck of the aneurysm sees great differences after endovascular treatment as compared with that before treatment, which also affects the wall shear stress and the displacement distribution. In addition, our whole simulation process is based on a series of CFD commercial software packages, which are easily available for doctors to implement such a method in their daily practice. These results would be used to assess the outcome of endovascular treatment for the aneurysm occlusion.

  16. Assessing Optimal Blood Pressure in Patients With Asymptomatic Aortic Valve Stenosis The Simvastatin Ezetimibe in Aortic Stenosis Study (SEAS)

    DEFF Research Database (Denmark)

    Nielsen, O. W.; Sajadieh, A.; Sabbah, M.

    2016-01-01

    BACKGROUND: Evidence for treating hypertension in patients with asymptomatic aortic valve stenosis is scarce. We used data from the SEAS trial (Simvastatin Ezetimibe in Aortic Stenosis) to assess what blood pressure (BP) would be optimal. METHODS: A total of 1767 patients with asymptomatic aortic...... stenosis and no manifest atherosclerotic disease were analyzed. Outcomes were all-cause mortality, cardiovascular death, heart failure, stroke, myocardial infarction, and aortic valve replacement. BP was analyzed in Cox models as the cumulative average of serially measured BP and a time-varying covariate...... to 69 mm Hg taken as reference. Low systolic and diastolic BPs increased risk in patients with moderate aortic stenosis. With a time-varying systolic BP from 130 to 139 mm Hg used as reference, mortality was increased for systolic BP ≥160 mm Hg (HR, 1.7; P=0.033) and BP of 120 to 129 mm Hg (HR, 1.6; P=0...

  17. Variation in assessment of oxidatively damaged DNA in mononuclear blood cells by the comet assay with visual scoring

    DEFF Research Database (Denmark)

    Forchhammer, Lykke; Bräuner, Elvira Vaclavik; Folkmann, Janne Kjaersgaard;

    2008-01-01

    The comet assay is popular for assessments of genotoxicity, but the comparison of results between studies is challenging because of differences in experimental procedures and reports of DNA damage in different units. We investigated the variation of DNA damage in mononuclear blood cells (MNBCs......) measured by the comet assay with focus on the variation related to alkaline unwinding and electrophoresis time, number of cells scored, as well as the putative benefits of transforming the primary end points to common units by the use of reference standards and calibration curves. Eight experienced......-response relationships of cells exposed to gamma-radiation and it was possible to reduce the variation in oxidized purines in MNBCs from humans by adjusting the level of lesions with protocol-specific calibration curves. However, there was a difference in the level of DNA damage measured by different investigators...

  18. Quantitative assessment of blood flow reserve using {sup 99m}Tc-HMPAO in carotid stenosis

    Energy Technology Data Exchange (ETDEWEB)

    Garai, I.; Varga, J.; Galuska, L. [Department of Nuclear Medicine, University of Debrecen Medical and Health Centre, Debrecen (Hungary); Szomjak, E. [3. Department of Internal Medicine, University of Debrecen Medical and Health Centre, Debrecen (Hungary); Toth, C.; Olvaszto, S. [1. Department of Surgery, University of Debrecen Medical and Health Centre, Debrecen (Hungary); Bank, J. [Department of Neurology, Kenezy Hospital (Hungary); Ficzere, A. [Department of Neurology, University of Debrecen Medical and Health Centre, Debrecen (Hungary)

    2002-02-01

    Dynamic imaging of the inflow of technetium-99m hexamethylpropylene amine oxime (HMPAO) to the brain has been proved to allow estimation of the hemispherical cerebral blood flow (CBF) using the Patlak plot. In this study, we compared the hemispherical CBF (in ml/min/100 g) of different patient groups. A total of 25 patients (comprising 13 with migraine and 12 scheduled for endarterectomy owing to angiographically confirmed severe stenosis of the internal carotid artery on at least one side) underwent baseline and acetazolamide {sup 99m}Tc-HMPAO brain perfusion studies. In addition, acetazolamide {sup 99m}Tc-HMPAO studies were performed in 12 healthy subjects (no baseline study was performed for ethical reasons.) Dynamic studies were acquired by means of a dual-detector gamma camera with a large field of view (HELIX, Elscint). Special difference images were created to make definition of the aortic arch and hemispherical brain regions easier and more reproducible. A semi-automatic method was developed to determine the transit time from the aorta to the brain, making the generation of the Patlak plot even more robust. The baseline CBF values did not significantly depend on the disease (P>0.1), whereas the CBF values obtained after acetazolamide provocation did do so (ANOVA, P<0.001). Patients suffering from migraine showed a significant increase in global CBF values after acetazolamide provocation (paired t test, P<0.05), but we could not find any effect of the provocation in patients awaiting carotid endarterectomy, indicating a lack of cerebrovascular reserve capacity. Comparison of the results of the acetazolamide study in patients and the control group revealed the CBF values to be significantly lower in patients with carotid stenosis (two-sample t-test, P<0.001), but not in those with migraine (P>0.1). In summary, using quantitative analysis of {sup 99m}Tc-HMPAO brain studies we could objectively compare the CBF of patients suffering from different diseases

  19. Strength, corrosion resistance, and biocompatibility of ultrafine-grained Mg alloys after different modes of severe plastic deformation

    Science.gov (United States)

    Dobatkin, S. V.; Lukyanova, E. A.; Martynenko, N. S.; Anisimova, N. Yu; Kiselevskiy, M. V.; Gorshenkov, M. V.; Yurchenko, N. Yu; Raab, G. I.; Yusupov, V. S.; Birbilis, N.; Salishchev, G. A.; Estrin, Y. Z.

    2017-05-01

    The effect of severe plastic deformation on the structure, mechanical properties, corrosion resistance, and biocompatibility of the WE43 (Mg-Y-Nd-Zr) alloy earmarked for applications as bioresorbable material has been studied. The alloy was deformed by rotary swaging (RS), equal channel angular pressing (ECAP), and multiaxial deformation (MAD). The microstructure examination by transmission electron microscopy showed that all SPD modes lead to the formation of ultrafine-grained structure with a structural element size of 0.5-1 µm and the Mg12Nd phase particles 0.3 µm in size. The microstructure refinement by all three treatments resulted in strengthening of the alloy. ECAP and MAD also raised ductility to up to 12-17%, while RS increased the ultimate tensile strength to up to 415 MPa. The study of the corrosion properties showed that SPD does not affect the electrochemical corrosion of the alloy. Its biocompatibility in vitro was estimated after incubation of the samples with red blood cells (hemolysis study), white blood cells (cell viability assay), and mesenchymal stromal cells (cell proliferation analysis). The biodegradation rate in fetal bovine serum was also evaluated. ECAP and MAD were found to cause some deceleration of biodegradation by slowing down the gas formation in the biological fluid and, compared to MSC, to improve the biocompatibility of the WE43 alloy.

  20. Malachite green toxicity assessed on Asian catfish primary cultures of peripheral blood mononuclear cells by a proteomic analysis.

    Science.gov (United States)

    Pierrard, Marie-Aline; Kestemont, Patrick; Delaive, Edouard; Dieu, Marc; Raes, Martine; Silvestre, Frédéric

    2012-06-15

    The potential genotoxic and carcinogenic properties reported for malachite green (MG) and the frequent detection of MG residues in fish and fish products, despite the ban of MG, have recently generated great concern. Additional toxicological data are required for a better understanding of the mechanism of action and a more comprehensive risk assessment for the exposure of fish to this fungicide. To date, the use of fish peripheral blood mononuclear cells (PBMCs) has not been exploited as a tool in the assessment of the toxicity of chemicals. However, PBMCs are exposed to toxicants and can be easily collected by blood sampling. The present study aims at better understanding the effects of MG by a proteomic analysis of primary cultured PBMC from the Asian catfish, Pangasianodon hypophthalmus, exposed to MG. The two lowest concentrations of 1 and 10 ppb were selected based on the MTS (water soluble tetrazolium salts) cytotoxicity test. Using a proteomic analysis (2D-DIGE), we showed that 109 proteins displayed significant changes in abundance in PBMC exposed during 48 h to MG. Most of these proteins were successfully identified by nano LC-MS/MS and validated through the Peptide and Protein Prophet of Scaffold™ software, but only 19 different proteins were considered corresponding to a single identification per spot. Our data suggest that low concentrations of MG could affect the mitochondrial metabolic functions, impair some signal transduction cascades and normal cell division, stimulate DNA repair and disorganize the cytoskeleton. Altogether, these results confirm that the mitochondrion is a target of MG toxicity. Further studies on the identified proteins are needed to better understand the mechanisms of MG toxicity in fish produced for human consumption.

  1. Improved Methodology for Assessment of mRNA Levels in Blood of Patients with FMR1 Related Disorders

    Directory of Open Access Journals (Sweden)

    Godler David E

    2009-06-01

    do not conform to the conventional rRNA criteria can still be utilized to obtain biologically/clinically relevant data. Although, this strategy clearly has application for improved assessment of FMR1 mRNA toxicity in blood, it may also have more general implications for gene expression studies in fresh and archival tissues.

  2. Assessing endothelial function and providing calibrated UFMD data using a blood pressure cuff

    Energy Technology Data Exchange (ETDEWEB)

    Maltz, Jonathan S.

    2017-08-22

    Methods and apparatus are provided for assessing endothelial function in a mammal. In certain embodiments the methods involve using a cuff to apply pressure to an artery in a subject to determine a plurality of baseline values for a parameter related to endothelial function as a function of applied pressure (P.sub.m); b) applying a stimulus to the subject; and applying external pressure P.sub.m to the artery to determine a plurality of stimulus-effected values for the parameter related to endothelial function as a function of applied pressure (P.sub.m); where the baseline values are determined from measurements made when said mammal is not substantially effected by said stimulus and differences in said baseline values and said stimulus-effected values provide a measure of endothelial function in said mammal.

  3. Whole blood gene expression profiles to assess pathogenesis and disease severity in infants with respiratory syncytial virus infection.

    Directory of Open Access Journals (Sweden)

    Asuncion Mejias

    2013-11-01

    Full Text Available BACKGROUND: Respiratory syncytial virus (RSV is the leading cause of viral lower respiratory tract infection (LRTI and hospitalization in infants. Mostly because of the incomplete understanding of the disease pathogenesis, there is no licensed vaccine, and treatment remains symptomatic. We analyzed whole blood transcriptional profiles to characterize the global host immune response to acute RSV LRTI in infants, to characterize its specificity compared with influenza and human rhinovirus (HRV LRTI, and to identify biomarkers that can objectively assess RSV disease severity. METHODS AND FINDINGS: This was a prospective observational study over six respiratory seasons including a cohort of infants hospitalized with RSV (n = 135, HRV (n = 30, and influenza (n = 16 LRTI, and healthy age- and sex-matched controls (n = 39. A specific RSV transcriptional profile was identified in whole blood (training cohort, n = 45 infants; Dallas, Texas, US and validated in three different cohorts (test cohort, n = 46, Dallas, Texas, US; validation cohort A, n = 16, Turku, Finland; validation cohort B, n = 28, Columbus, Ohio, US with high sensitivity (94% [95% CI 87%-98%] and specificity (98% [95% CI 88%-99%]. It classified infants with RSV LRTI versus HRV or influenza LRTI with 95% accuracy. The immune dysregulation induced by RSV (overexpression of neutrophil, inflammation, and interferon genes, and suppression of T and B cell genes persisted beyond the acute disease, and immune dysregulation was greatly impaired in younger infants (<6 mo. We identified a genomic score that significantly correlated with outcomes of care including a clinical disease severity score and, more importantly, length of hospitalization and duration of supplemental O2. CONCLUSIONS: Blood RNA profiles of infants with RSV LRTI allow specific diagnosis, better understanding of disease pathogenesis, and assessment of disease severity. This study opens new avenues

  4. Double-echo perfusion-weighted MR imaging: basic concepts and application in brain tumors for the assessment of tumor blood volume and vascular permeability

    OpenAIRE

    Uematsu, Hidemasa; Maeda, Masayuki

    2006-01-01

    Perfusion-weighted magnetic resonance (MR) imaging using contrast agents plays a key role in characterizing tumors of the brain. We have shown that double-echo perfusion-weighted MR imaging (DEPWI) is potentially useful in assessing brain tumors. Quantitative indices, such as tumor blood volume, are obtained using DEPWI, which allows correction of underestimation of tumor blood volume due to leakage of contrast agents from tumor vessels, in addition to simultaneous acquisition of tumor vessel...

  5. Solubility of dense CO2 in two biocompatible acrylate copolymers

    Directory of Open Access Journals (Sweden)

    A. R. C. Duarte

    2006-06-01

    Full Text Available Biocompatible polymers and copolymers are frequently being used as part of controlled delivery systems. These systems can be prepared using a "clean and environment friendly" technology like supercritical fluids. One great advantage of this process is that compressed carbon dioxide has excellent plasticizing properties and can swell most biocompatible polymeric matrixes, thus promoting drug impregnation processes. Mass sorption of two acrylate biocompatible copolymers contact with supercritical carbon dioxide is reported. Equilibrium solubility of dense carbon dioxide in poly(methylmethacrylate-co-ethylhexylacrylate and poly(methylmethacrylate-co-ethylhexylacrylate-co-ethyleneglycoldimethacrylate was studied by a static method at 10.0 MPa and 313 K. The reticulated copolymer had Fickean behavior and its diffusion coefficient was calculated, under operating conditions.

  6. BIOCOMPATIBILITY EVALUATION OF XANTHAN/CHONDROITIN SULFATE HYDROGELS

    Directory of Open Access Journals (Sweden)

    Ana-Maria Oprea

    2012-03-01

    Full Text Available The in vitro and in vivo biocompatibility of xanthan/chondroitin sulfate hydrogels (X/CS in differentmixing ratios was investigated. The in vitro biocompatibility evaluation was performed by a chemiluminescent assayusing microorganisms such as Saccharomyces pombe. The cellular growth of S. pombe in presence of thexanthan/chondroitin sulfate hydrogels containing up to 20 % chondroitin sulfate was examinated comparatively withxanthan hydrogel.The in vivo evaluation was performed by toxicity test and subcutaneously implantation in rats. It has been establisheda lethal dose (LD50 bigger than 3200 mg/kg for all studied hydrogels, therefore they are nontoxic materials.The in vivo 30 days testing performed by subcutaneous implantation showed that the X/CS matrices were easilyabsorbed without side-effects, demonstrating their biocompatibility and effectiveness as potential drug delivery systems.

  7. Graft copolymerization of glycerol 1,3-diglycerolate diacrylate onto poly(3-hydroxyoctanoate) to improve physical properties and biocompatibility.

    Science.gov (United States)

    Kim, Hyung Woo; Chung, Moon Gyu; Kim, Young Baek; Rhee, Young Ha

    2008-10-01

    Glycerol 1,3-diglycerol diacrylate-grafted poly(3-hydroxyoctanoate) (GDD-g-PHO) copolymers were prepared by heating homogeneous solutions of PHO, GDD monomer and benzoylperoxide initiator. Experiments showed that GDD was successfully grafted onto the PHO chains and that the resulting copolymers had enhanced thermal properties and mechanical strengths. The surfaces and the bulk of GDD-g-PHO copolymers became more hydrophilic as the GDD grafting density in the copolymer increased. Measurements of the growth of Chinese hamster ovary cells and the adsorption of blood proteins and platelets in vitro showed that biocompatibility was also enhanced by grafting of GDD groups. These results indicate that the GDD-g-PHO copolymers are promising materials for biocompatible biomedical applications.

  8. Biocompatible SiO2 in the Fabrication of Stimuli-Responsive Hybrid Composites and Their Application Potential

    Directory of Open Access Journals (Sweden)

    Hasan Ahmad

    2015-01-01

    Full Text Available Organic/inorganic hybrid composite materials have been extensively studied as they combine the properties of inorganic material and organic polymer. Among the inorganic material biocompatible silica (SiO2 is an interesting candidate for application in biotechnology because such material is wide spread in nature as well as in medicine. During the last few decades, stimuli-responsive polymers are drawing much attention from the researchers for application versatility such as target-specific delivery of drug and corrosion inhibitors. Considering the biocompatibility and many such important properties as high cargo loading capacity, long blood circulation lifetime, enhanced permeability and retention, mechanical strength, and easy processability, combination of SiO2 particles with stimuli-responsive polymers is gaining attention over the last decade. This review article will report the progress made towards the development and application of stimuli-responsive hybrid composites based on SiO2.

  9. A pilot assessment of alpha-stat vs pH-stat arterial blood gas analysis after cardiac arrest.

    Science.gov (United States)

    Eastwood, Glenn M; Suzuki, Satoshi; Lluch, Cristina; Schneider, Antoine G; Bellomo, Rinaldo

    2015-02-01

    Resuscitated cardiac arrest (CA) patients typically receive therapeutic hypothermia, but arterial blood gases (ABGs) are often assessed after adjustment to 37°C (alpha-stat) instead of actual body temperature (pH-stat). We sought to compare alpha-stat and pH-stat assessment of PaO2 and PaCO2 in such patients. Using ABG data obtained during the first 24 hours of intensive care unit admission, we determined the impact of measured alpha vs calculated pH-stat on PaO2 and PaCO2 on patient classification and outcomes for CA patients. We assessed 1013 ABGs from 120 CA patients with a median age of patients 66 years (interquartile range, 50-76). Median alpha-stat PaO2 changed from 122 (95-156) to 107 (82-143) mm Hg with pH-stat and median PaCO2 from 39 (34-46) to 35 (30-41) mm Hg (both P < .001). Using the categories of hyperoxemia, normoxemia, and hypoxemia, pH-stat estimation of PaO2 reclassified approximately 20% of patients. Using the categories of hypercapnia, normocapnia, and hypocapnia, pH stat estimation of PaCO2 reclassified approximately 40% of patients. The mortality of patients in different PaO2 and PaCO2 categories was similar for pH-stat and alpha-stat. Using the pH-stat method, fewer resuscitated CA patients admitted to intensive care unit were classified as hyperoxemic or hypercapnic compared with alpha-stat. These findings suggest an impact of ABG assessment methodology on PaO2, PaCO2 , and patient classification but not on associated outcomes. Copyright © 2014 Elsevier Inc. All rights reserved.

  10. Blood sugar test - blood

    Science.gov (United States)

    ... blood glucose level ( hypoglycemia ) may be due to: Hypopituitarism (a pituitary gland disorder) Underactive thyroid gland or ... tonic-clonic seizure Glucagon blood test Glucagonoma Hyperthyroidism Hypopituitarism Hypothyroidism Insulinoma Low blood sugar Multiple endocrine neoplasia ( ...

  11. A novel method to in vitro evaluate biocompatibility of nanoscaled scaffolds.

    Science.gov (United States)

    Li, Xiaoming; Wang, Zheng; Zhao, Tianxiao; Yu, Bo; Fan, Yubo; Feng, Qingling; Cui, Fu-Zhai; Watari, Fumio

    2016-09-01

    This study provided a new method to in vitro evaluate the biocompatibility of nanoscaled scaffolds for tissue engineering with neutrophils other than ordinary cell culture. The neutrophils were separated from human peripheral blood of healthy subjects. In vitro degradation product of nanohydroxyapatite/collagen (nHAC), nanohydroxyapatite/collagen/poly (L-lactic acid) (nHACP), and nHACP reinforced by chitin fibers (nHACP/CF) in the D-Hank's Balanced Salt Solution (D-HBSS) was used as the testing solution, which was thereafter mixed with the neutrophils. It was shown that the cell survival rate in the testing solutions had no significant difference from that in the D-HBSS (control). However, from both gene and protein expression levels, the lactate dehydrogenase and tumor necrosis factor-alpha of the neutrophils in the nHACP/CF testing solution were found lowest during the whole testing period; the main reasons of which might be that the calcium release rate of the scaffold was slowest and that the pH value of its degradation solution was nearest to that of human body. Moreover, in vivo experiments showed that most inflammation reactions happened for nHAC and poly (L-lactic acid) groups, while the least inflammation reactions happened for nHACP/CF group in the subcutaneous dorsum of mice at 2 weeks after the surgery, which confirmed the in vitro findings. These results indicated that the pH value and the certain metal iron concentration of the nanoscaled scaffold degradation solution should be two important factors that significantly affect its biocompatibility. This study provides a simple and effective biocompatibility test method for biodegradable nanoscaled tissue engineering scaffolds. © 2016 Wiley Periodicals, Inc. J Biomed Mater Res Part A: 104A: 2117-2125, 2016. © 2016 Wiley Periodicals, Inc.

  12. The Comparison of Biocompatibility Properties between Ti Alloys and Fluorinated Diamond-Like Carbon Films

    Directory of Open Access Journals (Sweden)

    Chavin Jongwannasiri

    2012-01-01

    Full Text Available Titanium and titanium alloys have found several applications in the biomedical field due to their unique biocompatibility. However, there are problems associated with these materials in applications in which there is direct contact with blood, for instance, thrombogenesis and protein adsorption. Surface modification is one of the effective methods used to improve the performance of Ti and Ti alloys in these circumstances. In this study, fluorinated diamond-like carbon (F-DLC films are chosen to take into account the biocompatible properties compared with Ti alloys. F-DLC films were prepared on NiTi substrates by a plasma-based ion implantation (PBII technique using acetylene (C2H2 and tetrafluoromethane (CF4 as plasma sources. The structure of the films was characterized by Raman spectroscopy. The contact angle and surface energy were also measured. Protein adsorption was performed by treating the films with bovine serum albumin and fibrinogen. The electrochemical corrosion behavior was investigated in Hanks’ solution by means of a potentiodynamic polarization technique. Cytotoxicity tests were performed using MTT assay and dyed fluorescence. The results indicate that F-DLC films present their hydrophobic surfaces due to a high contact angle and low surface energy. These films can support the higher albumin-to-fibrinogen ratio as compared to Ti alloys. They tend to suppress the platelet adhesion. Furthermore, F-DLC films exhibit better corrosion resistance and less cytotoxicity on their surfaces. It can be concluded that F-DLC films can improve the biocompatibility properties of Ti alloys.

  13. Nepenthes khasiana mediated synthesis of stabilized gold nanoparticles: Characterization and biocompatibility studies.

    Science.gov (United States)

    Dhamecha, Dinesh; Jalalpure, Sunil; Jadhav, Kiran

    2016-01-01

    The current study summarizes a unique green process for the synthesis of gold nanoparticles by simple treatment of gold salts with aqueous extract of Nepenthes khasiana (NK)--a red listed medicinal plant and its characterization. Study on the effect of different process parameters like temperature, pH and stirring on surface and stability characteristics has been demonstrated. Formation of GNPs was visually observed by change in color from colorless to wine red and characterized by UV-Visible spectroscopy, FT-IR spectroscopy, Zetasizer, X-RD, ICP-AES, SEM-EDAX, AFM and TEM. In vitro stability studies of gold colloidal dispersion in various blood components suggest that, NK mediated GNPs exhibit remarkable in vitro stability in 2% bovine serum albumin, 2% human serum albumin (HSA), 0.2M histidine, and 0.2M cysteine but unstable in 5% NaCl solution and acidic pH. Biocompatibility of NK stabilized GNPs against normal mouse fibroblasts (L929) cell lines revealed nontoxic nature of GNPs and thus provides exceptional opportunities for their uses as nanomedicine for diagnosis and drug therapy. The role of antioxidant phytochemicals (flavonoids and polyphenols) of NK extract in synthesis of biocompatible and stabilized GNPs was demonstrated by estimating total flavonoid content, total phenolic content and total antioxidant capacity of extract before and after formation of GNPs. Fast and easy synthesis of biocompatible GNPs possesses unique physical and chemical features which serve as an advantage for its use in various biomedical applications. The overall approach designated in the present research investigation for the synthesis of GNPs is based on all 12 principles of green chemistry, in which no man-made chemical other than the gold chloride was used.

  14. Biocompatibility study of two diblock copolymeric nanoparticles for biomedical applications by in vitro toxicity testing

    Science.gov (United States)

    Goñi-de-Cerio, Felipe; Mariani, Valentina; Cohen, Dror; Madi, Lea; Thevenot, Julie; Oliveira, Hugo; Uboldi, Chiara; Giudetti, Guido; Coradeghini, Rosella; Garanger, Elisabeth; Rossi, François; Portugal-Cohen, Meital; Oron, Miriam; Korenstein, Rafi; Lecommandoux, Sébastien; Ponti, Jessica; Suárez-Merino, Blanca; Heredia, Pedro

    2013-11-01

    Drugs used for chemotherapy normally carry out adverse, undesired effects. Nanotechnology brings about new horizons to tackle cancer disease with a different strategy. One of the most promising approaches is the use of nanocarriers to transport active drugs. These nanocarriers need to have special properties to avoid immune responses and toxicity, and it is critical to study these effects. Nanocarriers may have different nature, but polypeptide-based copolymers have attracted considerable attention for their biocompatibility, controlled and slow biodegradability as well as low toxicity. Little has been done regarding specific nanocarriers toxicity. In this study, we performed a thorough toxicological study of two different block copolymer nanoparticles (NPs); poly(trimethylene carbonate)- block-poly( l-glutamic acid) (PTMC- b-PGA) and poly(ethylene glycol)- block-poly( γ-benzyl- l-glutamate) (PEG- b-PBLG) with sizes between 113 and 131 nm. Low blood-serum-protein interaction was observed. Moreover, general toxicity assays and other endpoints (apoptosis or necrosis) showed good biocompatibility for both NPs. Reactive oxygen species increased in only two cell lines (HepG2 and TK6) in the presence of PTMC- b-PGA. Cytokine production study showed cytokine induction only in one cell line (A549). We also performed the same assays on human skin organ culture before and after UVB light treatment, with a moderate toxicity after treatment independent of NPs presence or absence. Interleukin 1 induction was also observed due to the combined effect of PEG- b-PBLG and UVB light irradiation. Future in vivo studies for biocompatibility and toxicity will provide more valuable information, but, so far, the findings presented here suggest the possibility of using these two NPs as nanocarriers for nanomedical applications, always taking into account the application procedure and the way in which they are implemented.

  15. The quantification of biocompatibility: toward a new definition

    Science.gov (United States)

    Ratner, Buddy

    2008-03-01

    Implantable medical devices, and the biomaterials that comprise them, form a 100B business worldwide. Medical devices save lives and/or improve the quality of life for millions. Tissue engineering also makes extensive use of biomaterials -- biomaterials are an enabling technology for tissue engineering. A central word to understanding the effectiveness of such materials and devices is biocompatibility. The word ``biocompatible'' is widely used in reference to biomaterials and medical devices and most everyone has some value understanding of its meaning. Many formal definitions have been proposed for this word, but it is still largely used in an imprecise manner. Four descriptions or definitions of biocompatibility will be reviewed: a widely adopted definition from a consensus conference, a surgeon's perspective on this word, the regulatory agency view and the factors that clearly influence biocompatibility. In this talk, the classical definition of biocompatibility will be contrasted to a newer definition embracing molecular concepts and the understanding of normal wound healing. The biological data on the in vivo healing responses of mammals to implants will be described. A strategy to improve the healing of biomaterials will be presented. It is based upon surface molecular engineering. First, non-specific protein adsorption must be inhibited. Strategies to achieve this design parameter will be presented. Then methods to deliver the specific protein signals will be addressed. Matricellular proteins such as osteopontin, thrombospondin 2 and SPARC will be introduced with an emphasis on exploiting the special reactivity of such proteins. A discussion of the influence of surface textures and porosities will also be presented. Finally a new scheme based upon macrophage phenotypic pathways will be proposed that may allow a quantitative measure of extent of biocompatibility.

  16. Cysteine modified polyaniline films improve biocompatibility for two cell lines

    Energy Technology Data Exchange (ETDEWEB)

    Yslas, Edith I., E-mail: eyslas@exa.unrc.edu.ar [Departamento de Biología Molecular, Universidad Nacional de Río Cuarto, Agencia Postal Nro3, X580BYA Río Cuarto (Argentina); Cavallo, Pablo; Acevedo, Diego F.; Barbero, César A. [Departamento de Química, Universidad Nacional de Río Cuarto, Agencia Postal Nro3, X580BYA Río Cuarto (Argentina); Rivarola, Viviana A. [Departamento de Biología Molecular, Universidad Nacional de Río Cuarto, Agencia Postal Nro3, X580BYA Río Cuarto (Argentina)

    2015-06-01

    This work focuses on one of the most exciting application areas of conjugated conducting polymers, which is cell culture and tissue engineering. To improve the biocompatibility of conducting polymers we present an easy method that involves the modification of the polymer backbone using L-cysteine. In this publication, we show the synthesis of polyaniline (PANI) films supported onto Polyethylene terephthalate (PET) films, and modified using cysteine (PANI-Cys) in order to generate a biocompatible substrate for cell culture. The PANI-Cys films are characterized by Fourier Transform infrared and UV–visible spectroscopy. The changes in the hydrophilicity of the polymer films after and before the modification were tested using contact angle measurements. After modification the contact angle changes from 86° ± 1 to 90° ± 1, suggesting a more hydrophylic surface. The adhesion properties of LM2 and HaCaT cell lines on the surface of PANI-Cys films in comparison with tissue culture plastic (TCP) are studied. The PANI-Cys film shows better biocompatibility than PANI film for both cell lines. The cell morphologies on the TCP and PANI-Cys film were examined by florescence and Atomic Force Microscopy (AFM). Microscopic observations show normal cellular behavior when PANI-Cys is used as a substrate of both cell lines (HaCaT and LM2) as when they are cultured on TCP. The ability of these PANI-Cys films to support cell attachment and growth indicates their potential use as biocompatible surfaces and in tissue engineering. - Highlights: • A new surface PANI-Cys was produced on films of polyethylene terephthalate. • The relationship between surface characteristics and biocompatibility is analyzed. • The PANI-Cys film presents good biocompatibility for two cell lines.

  17. Synthesis of Biocompatible Hydroxyapatite Using Chitosan Oligosaccharide as a Template

    Directory of Open Access Journals (Sweden)

    Jinyu Wang

    2015-11-01

    Full Text Available In this study, a novel biocompatible hydroxyapatite (HA was synthesized by using chitosan oligosaccharide (COS as a template. These HA samples were studied by Fourier transform infrared (FTIR spectroscopy, X-ray diffraction (XRD, X-ray photoelectron spectroscopy (XPS, and transmission electron microscopy (TEM. The biocompatibility of HA samples was evaluated via cell viability, cell morphology and alkaline phosphatase staining of MG-63 cell lines. The results show that HA synthesized in the presence of COS was favorable to proliferation and osteogenic differentiation of MG-63 cells. These hydroxyapatites are potentially attractive biomaterials for bone tissue engineering applications.

  18. [Study on biocompatibility of MIM 316L stainless steel].

    Science.gov (United States)

    Wang, Guohui; Zhu, Shaihong; Li, Yiming; Zhao, Yanzhong; Zhou, Kechao; Huang, Boyun

    2007-04-01

    This study was aimed to evaluate the biocompatibility of metal powder injection molding (MIM) 316L stainless steel. The percentage of S-period cells was detected by flow cytometry after L929 cells being incubated with extraction of MIM 316L stainless steel, and titanium implant materials for clinical application were used as control. In addition, both materials were implanted in animals and the histopathological evaluations were carried out. The statistical analyses show that there are no significant differences between the two groups (P > 0.05), which demonstrate that MIM 316L stainless steel has good biocompatibility.

  19. Assessment of Blood Flow in Hepatocellular Carcinoma: Correlations of Computed Tomography Perfusion Imaging and Circulating Angiogenic Factors

    Directory of Open Access Journals (Sweden)

    Chen-Pin Chou

    2013-08-01

    Full Text Available Hepatocellular carcinoma (HCC is a highly vascular tumor through the process of angiogenesis. To evaluate more non-invasive techniques for assessment of blood flow (BF in HCC, this study examined the relationships between BF of HCC measured by computer tomography (CT perfusion imaging and four circulating angiogenic factors in HCC patients. Interleukin 6 (IL-6, interleukin 8 (IL-8, vascular endothelial growth factor (VEGF, and platelet derived growth factor (PDGF in plasma were measured using Bio-Plex multiplex immunoassay in 21 HCC patients and eight healthy controls. Circulating IL-6, IL-8 and VEGF showed higher concentrations in HCC patients than in controls (p < 0.05, and predicted HCC occurrence better than chance (p < 0.01. Twenty-one patients with HCC received 21-phase liver imaging using a 64-slice CT. Total BF, arterial BF, portal BF, arterial fraction (arterial BF/total BF of the HCC and surrounding liver parenchyma, and HCC-parenchyma ratio were measured using a dual-vessel model. After analyzing the correlations between BF in HCC and four circulating angiogenic factors, we found that the HCC-parenchyma ratio of arterial BF showed a significantly positive correlation with the level of circulating IL-8 (p < 0.05. This circulating biomarker, IL-8, provides a non-invasive tool for assessment of BF in HCC.

  20. Blood pressure circadian pattern and physical exercise assessment by accelerometer and 7-day physical activity recall scale.

    Science.gov (United States)

    García-Ortiz, Luis; Recio-Rodríguez, José I; Puig-Ribera, Anna; Lema-Bartolomé, Jorge; Ibáñez-Jalón, Elisa; González-Viejo, Natividad; Guenaga-Saenz, Nahia; Agudo-Conde, Cristina; Patino-Alonso, Maria C; Gomez-Marcos, Manuel A

    2014-05-01

    The relationship between regular physical activity, measured objectively and by self-report, and the circadian pattern of 24-hour ambulatory arterial blood pressure (BP) has not been clarified. We performed a cross-sectional study in a cohort of healthy patients. We included 1,345 patients from the EVIDENT study (mean age 55 ± 14 years; 59.3% women). Physical activity was assessed using the 7-day physical activity recall (PAR) questionnaire (metabolic equivalents (MET)/hour/week) and the Actigraph GT3X accelerometer (counts/minute) for 7 days; ambulatory arterial BP was measured with a radial tonometer (B-pro device). The dipper-pattern patients showed a higher level of activity than nondipper patients, as assessed by accelerometer and 7-day PAR. Physical activity measures correlated positively with the percent drop in systolic BP (SBP; ρ = 0.19 to 0.11; P Physical activity, as evaluated by both the accelerometer and the 7-day PAR, was associated with a more marked nocturnal BP dip and, accordingly, a lower SBP and diastolic BP sleep to wake ratio. Clinical Trials.gov Identifier: NCT01083082.

  1. The 2013 Canadian Hypertension Education Program recommendations for blood pressure measurement, diagnosis, assessment of risk, prevention, and treatment of hypertension.

    Science.gov (United States)

    Hackam, Daniel G; Quinn, Robert R; Ravani, Pietro; Rabi, Doreen M; Dasgupta, Kaberi; Daskalopoulou, Stella S; Khan, Nadia A; Herman, Robert J; Bacon, Simon L; Cloutier, Lyne; Dawes, Martin; Rabkin, Simon W; Gilbert, Richard E; Ruzicka, Marcel; McKay, Donald W; Campbell, Tavis S; Grover, Steven; Honos, George; Schiffrin, Ernesto L; Bolli, Peter; Wilson, Thomas W; Feldman, Ross D; Lindsay, Patrice; Hill, Michael D; Gelfer, Mark; Burns, Kevin D; Vallée, Michel; Prasad, G V Ramesh; Lebel, Marcel; McLean, Donna; Arnold, J Malcolm O; Moe, Gordon W; Howlett, Jonathan G; Boulanger, Jean-Martin; Larochelle, Pierre; Leiter, Lawrence A; Jones, Charlotte; Ogilvie, Richard I; Woo, Vincent; Kaczorowski, Janusz; Trudeau, Luc; Petrella, Robert J; Milot, Alain; Stone, James A; Drouin, Denis; Lavoie, Kim L; Lamarre-Cliche, Maxime; Godwin, Marshall; Tremblay, Guy; Hamet, Pavel; Fodor, George; Carruthers, S George; Pylypchuk, George B; Burgess, Ellen; Lewanczuk, Richard; Dresser, George K; Penner, S Brian; Hegele, Robert A; McFarlane, Philip A; Sharma, Mukul; Reid, Debra J; Tobe, Sheldon W; Poirier, Luc; Padwal, Raj S

    2013-05-01

    We updated the evidence-based recommendations for the diagnosis, assessment, prevention, and treatment of hypertension in adults for 2013. This year's update includes 2 new recommendations. First, among nonhypertensive or stage 1 hypertensive individuals, the use of resistance or weight training exercise does not adversely influence blood pressure (BP) (Grade D). Thus, such patients need not avoid this type of exercise for fear of increasing BP. Second, and separately, for very elderly patients with isolated systolic hypertension (age 80 years or older), the target for systolic BP should be patients. We also discuss 2 additional topics at length (the pharmacological treatment of mild hypertension and the possibility of a diastolic J curve in hypertensive patients with coronary artery disease). In light of several methodological limitations, a recent systematic review of 4 trials in patients with stage 1 uncomplicated hypertension did not lead to changes in management recommendations. In addition, because of a lack of prospective randomized data assessing diastolic BP thresholds in patients with coronary artery disease and hypertension, no recommendation to set a selective diastolic cut point for such patients could be affirmed. However, both of these issues will be examined on an ongoing basis, in particular as new evidence emerges.

  2. Assessment of blood and oxygen delivery to flaps of rhesus using near infrared steady-state spectroscopy

    Institute of Scientific and Technical Information of China (English)

    2002-01-01

    Near infrared spectroscopy has been considered as a potentially ideal noninvasive technique for the postoperative monitoring of plastic surgery. In this study, 6 flaps were raised on rhesus monkeys' forearms. Blood and oxygen delivery to these flaps was monitored following vascular occlusions and inhalation of pure oxygen. Optical fibers were adopted in the probe of the oximeter so that the cutaneous detection could be performed in reflectance mode. Different and repeatable patterns of changes were measured following vascular occlusions on flaps. It is clear that the near infrared spectroscopy is capable of postoperatively monitoring vascular problems in flaps, especially the venous problem. Near infrared spectroscopy showed high sensitivity to detect the dynamic changes in flaps induced by inhalation of pure oxygen in this study. The experimental results indicated that it was potential to assess tissue viability utilizing the dynamic changes induced by some noninvasive stimulation (such as inhaling pure oxygen). It may be a new assessing method that is rapid, little influenced by other factors and less inconvenient to patients.

  3. Blood flow index using near-infrared spectroscopy and indocyanine green as a minimally invasive tool to assess respiratory muscle blood flow in humans.

    Science.gov (United States)

    Guenette, Jordan A; Henderson, William R; Dominelli, Paolo B; Querido, Jordan S; Brasher, Penelope M; Griesdale, Donald E G; Boushel, Robert; Sheel, A William

    2011-04-01

    Near-infrared spectroscopy (NIRS) in combination with indocyanine green (ICG) dye has recently been used to measure respiratory muscle blood flow (RMBF) in humans. This method is based on the Fick principle and is determined by measuring ICG in the respiratory muscles using transcutaneous NIRS in relation to the [ICG] in arterial blood as measured using photodensitometry. This method is invasive since it requires arterial cannulation, repeated blood withdrawals, and reinfusions. A less invasive alternative is to calculate a relative measure of blood flow known as the blood flow index (BFI), which is based solely on the NIRS ICG curve, thus negating the need for arterial cannulation. Accordingly, the purpose of this study was to determine whether BFI can be used to measure RMBF at rest and during voluntary isocapnic hyperpnea at 25, 40, 55, and 70% of maximal voluntary ventilation in seven healthy humans. BFI was calculated as the change in maximal [ICG] divided by the rise time of the NIRS-derived ICG curve. Intercostal and sternocleidomastoid muscle BFI were correlated with simultaneously measured work of breathing and electromyography (EMG) data from the same muscles. BFI showed strong relationships with the work of breathing and EMG for both respiratory muscles. The coefficients of determination (R(2)) comparing BFI vs. the work of breathing for the intercostal and sternocleidomastoid muscles were 0.887 (P < 0.001) and 0.863 (P < 0.001), respectively, whereas the R(2) for BFI vs. EMG for the intercostal and sternocleidomastoid muscles were 0.879 (P < 0.001) and 0.930 (P < 0.001), respectively. These data suggest that the BFI closely reflects RMBF in conscious humans across a wide range of ventilations and provides a less invasive and less technically demanding alternative to measuring RMBF.

  4. Comparison of blood aminotransferase methods for assessment of myopathy and hepatopathy in Florida manatees (Trichechus manatus latirostris).

    Science.gov (United States)

    Harr, Kendal E; Allison, Kathryn; Bonde, Robert K; Murphy, David; Harvey, John W

    2008-06-01

    Muscle injury is common in Florida manatees (Trichechus manatus latirostris). Plasma aspartate aminotransferase (AST) is frequently used to assess muscular damage in capture myopathy and traumatic injury. Therefore, accurate measurement of AST and alanine aminotransferase (ALT) is important in managed, free-ranging animals, as well as in those rehabilitating from injury. Activities of these enzymes, however, are usually not increased in manatees with either acute or chronic muscle damage, despite marked increases in plasma creatine kinase activity. It is hypothesized that this absence of response is due to apoenzymes in the blood not detected by commonly used veterinary assays. Addition of coenzyme pyridoxal-5-phosphate (P5P or vitamin B6) should, therefore, result in higher measured enzyme activities. The objective of this study was to determine the most accurate, precise, and diagnostically useful method for aminotransferase measurement in manatees that can be used in veterinary practices and diagnostic laboratories. Additionally, appropriate collection and storage techniques were assessed. The use of an optimized commercial wet chemical assay with 100 micromol P5P resulted in a positive bias of measured enzyme activities in a healthy population of animals. However, AST and ALT were still much lower than that typically observed in domestic animals and should not be used alone in the assessment of capture myopathy and muscular trauma. Additionally, the dry chemistry analyzer, typically used in clinics, reported significantly higher and less precise AST and ALT activities with poor correlation to those measured with wet chemical methods found in diagnostic laboratories. Therefore, these results cannot be clinically compared. Overall, the optimized wet chemical method was the most precise and diagnostically useful measurement of aminotransferase in samples. Additionally, there was a statistically significant difference between paired serum and plasma measurement

  5. Use of a whole blood competitive immunoassay for the assessment of worker exposures to propylene oxide at three manufacturing facilities.

    Science.gov (United States)

    Jones, Alan L; Van der Woord, Miriam; Bourrillon, François

    2005-04-01

    The level of N-(2-hydroxypropyl)valine adducts in haemoglobin has been shown to correlate well with workplace exposure to propylene oxide (PO). However, the analytical method, using the modified Edman degradation procedure, is prohibitively time-consuming and expensive for use as a routine workplace exposure measurement tool. As an alternative, AB Biomonitoring Ltd of Cardiff, Wales, developed a competitive immunoassay for the determination of N-(2-hydroxypropyl)valine adducts in human haemoglobin. Studies showed that whole blood samples analysed using an enzyme linked immunosorbent assay (ELISA) and the modified Edman degradation procedure over the concentration range 3.7-992 nmol N-(2-hydroxypropyl)valine g(-1) haemoglobin are in good agreement (correlation coefficient 0.998, n = 10). The intervariance and intravariance data indicate the repeatability of the ELISA method over the assay conditions employed and show that it is robust over its working range [2-200 pmol N-(2-hydroxypropyl)valine g(-1) haemoglobin]. The assay employs a whole blood matrix and has a working range of 2-6000 pmol g(-1) Hb (equivalent to up to 5 ppm PO exposure, 8 h per day, 5 days per week, over 4 months). The practicality of the assay was tested by assessing exposures to PO at three world-scale manufacturing sites in France and The Netherlands. Over 800 samples were taken over a 2 year period from operators, maintenance fitters and office staff. The data, typically immunoassay is a powerful tool for the exposure component of future epidemiology studies, as well as a definitive demonstration of the effectiveness of exposure controls.

  6. An integrative pharmacological approach to radio telemetry and blood sampling in pharmaceutical drug discovery and safety assessment

    Directory of Open Access Journals (Sweden)

    Kamendi Harriet W

    2011-01-01

    Full Text Available Abstract Background A successful integration of the automated blood sampling (ABS and telemetry (ABST system is described. The new ABST system facilitates concomitant collection of physiological variables with blood and urine samples for determination of drug concentrations and other biochemical measures in the same rat without handling artifact. Method Integration was achieved by designing a 13 inch circular receiving antenna that operates as a plug-in replacement for the existing pair of DSI's orthogonal antennas which is compatible with the rotating cage and open floor design of the BASi Culex® ABS system. The circular receiving antenna's electrical configuration consists of a pair of electrically orthogonal half-toroids that reinforce reception of a dipole transmitter operating within the coil's interior while reducing both external noise pickup and interference from other adjacent dipole transmitters. Results For validation, measured baclofen concentration (ABST vs. satellite (μM: 69.6 ± 23.8 vs. 76.6 ± 19.5, p = NS and mean arterial pressure (ABST vs. traditional DSI telemetry (mm Hg: 150 ± 5 vs.147 ± 4, p = NS variables were quantitatively and qualitatively similar between rats housed in the ABST system and traditional home cage approaches. Conclusion The ABST system offers unique advantages over traditional between-group study paradigms that include improved data quality and significantly reduced animal use. The superior within-group model facilitates assessment of multiple physiological and biochemical responses to test compounds in the same animal. The ABST also provides opportunities to evaluate temporal relations between parameters and to investigate anomalous outlier events because drug concentrations, physiological and biochemical measures for each animal are available for comparisons.

  7. Assessment of the genotoxic potential of contaminated estuarine sediments in fish peripheral blood: Laboratory versus in situ studies

    Energy Technology Data Exchange (ETDEWEB)

    Costa, Pedro M., E-mail: pmcosta@fct.unl.pt [IMAR-Instituto do Mar, Departamento de Ciencias e Engenharia do Ambiente, Faculdade de Ciencias e Tecnologia da Universidade Nova de Lisboa, 2829-516 Caparica (Portugal); Neuparth, Teresa S. [CIIMAR-Centro Interdisciplinar de Investigacao Marinha e Ambiental, Laboratorio de Toxicologia Ambiental, Universidade do Porto, Rua dos Bragas 289, 4050-123 Porto (Portugal); Caeiro, Sandra [IMAR-Instituto do Mar, Departamento de Ciencias e Engenharia do Ambiente, Faculdade de Ciencias e Tecnologia da Universidade Nova de Lisboa, 2829-516 Caparica (Portugal); Departamento de Ciencias e Tecnologia, Universidade Aberta, Rua da Escola Politecnica, 141, 1269-001 Lisboa (Portugal); Lobo, Jorge [IMAR-Instituto do Mar, Departamento de Ciencias e Engenharia do Ambiente, Faculdade de Ciencias e Tecnologia da Universidade Nova de Lisboa, 2829-516 Caparica (Portugal); Martins, Marta; Ferreira, Ana M.; Caetano, Miguel; Vale, Carlos [IPIMAR-INRB, Instituto Nacional dos Recursos Biologicos, Avenida de Brasilia, 1449-006 Lisboa (Portugal); Angel DelValls, T. [UNESCO/UNITWIN/WiCop Chair-Departamento de Quimica Fisica, Facultad de Ciencias del Mar y Ambientales, Universidad de Cadiz, Poligono rio San Pedro s/n, 11510 Puerto Real, Cadiz (Spain); Costa, Maria H. [IMAR-Instituto do Mar, Departamento de Ciencias e Engenharia do Ambiente, Faculdade de Ciencias e Tecnologia da Universidade Nova de Lisboa, 2829-516 Caparica (Portugal)

    2011-01-15

    Juvenile Senegalese soles (Solea senegalensis) were exposed to estuarine sediments through 28-day laboratory and in situ (field) bioassays. The sediments, collected from three distinct sites (a reference plus two contaminated) of the Sado Estuary (W Portugal) were characterized for total organic matter, redox potential, fine fraction and for the levels of metals, polycyclic aromatic hydrocarbons (PAHs) and organochlorines, namely polychlorinated biphenyls (PCBs) and dichloro diphenyl tricholoethane plus its main metabolites (DDTs). Genotoxicity was determined in whole peripheral blood by the single-cell gel electrophoresis (SCGE or 'comet') assay and by scoring erythrocytic nuclear abnormalities (ENA). Analysis was complemented with the determination of lipid peroxidation in blood plasma by the thiobarbituric acid reactive substances (TBARS) protocol and cell type sorting. The results showed that exposure to contaminated sediments induced DNA fragmentation and clastogenesis. Still, laboratory exposure to the most contaminated sediment revealed a possible antagonistic effect between metallic and organic contaminants that might have been enhanced by increased bioavailability. The laboratory assay caused a more pronounced increase in ENA whereas a very significant increase in DNA fragmentation was observed in field-tested fish exposed to the reference sediment, which is likely linked to increased lipid peroxidation that probably occurred due to impaired access to food. Influence of natural pathogens was ruled out by unaltered leukocyte counts. The statistical integration of data correlated lipid peroxidation with biological variables such as fish length and weight, whereas the genotoxicity biomarkers were more correlated to sediment contamination. It was demonstrated that laboratory and field bioassays for the risk assessment of sediment contamination may yield different genotoxicity profiles although both provided results that are in overall accordance with

  8. Assessment of the genotoxic potential of contaminated estuarine sediments in fish peripheral blood: laboratory versus in situ studies.

    Science.gov (United States)

    Costa, Pedro M; Neuparth, Teresa S; Caeiro, Sandra; Lobo, Jorge; Martins, Marta; Ferreira, Ana M; Caetano, Miguel; Vale, Carlos; DelValls, T Angel; Costa, Maria H

    2011-01-01

    Juvenile Senegalese soles (Solea senegalensis) were exposed to estuarine sediments through 28-day laboratory and in situ (field) bioassays. The sediments, collected from three distinct sites (a reference plus two contaminated) of the Sado Estuary (W Portugal) were characterized for total organic matter, redox potential, fine fraction and for the levels of metals, polycyclic aromatic hydrocarbons (PAHs) and organochlorines, namely polychlorinated biphenyls (PCBs) and dichloro diphenyl tricholoethane plus its main metabolites (DDTs). Genotoxicity was determined in whole peripheral blood by the single-cell gel electrophoresis (SCGE or "comet") assay and by scoring erythrocytic nuclear abnormalities (ENA). Analysis was complemented with the determination of lipid peroxidation in blood plasma by the thiobarbituric acid reactive substances (TBARS) protocol and cell type sorting. The results showed that exposure to contaminated sediments induced DNA fragmentation and clastogenesis. Still, laboratory exposure to the most contaminated sediment revealed a possible antagonistic effect between metallic and organic contaminants that might have been enhanced by increased bioavailability. The laboratory assay caused a more pronounced increase in ENA whereas a very significant increase in DNA fragmentation was observed in field-tested fish exposed to the reference sediment, which is likely linked to increased lipid peroxidation that probably occurred due to impaired access to food. Influence of natural pathogens was ruled out by unaltered leukocyte counts. The statistical integration of data correlated lipid peroxidation with biological variables such as fish length and weight, whereas the genotoxicity biomarkers were more correlated to sediment contamination. It was demonstrated that laboratory and field bioassays for the risk assessment of sediment contamination may yield different genotoxicity profiles although both provided results that are in overall accordance with sediment

  9. Anionic linear-globular dendrimers: biocompatible hybrid materials with potential uses in nanomedicine.

    Science.gov (United States)

    Alavidjeh, Mohammad Shafiee; Haririan, Ismaeil; Khorramizadeh, Mohammad Reza; Ghane, Zohre Zarei; Ardestani, Mehdi Shafiee; Namazi, Hassan

    2010-04-01

    The use of dendrimers as nano-sized excipients/vectors in biological and pharmaceutical systems is dependent on the investigation of their toxicological profiles in biological media. In this study, a series of mechanistic in vitro structure-associated cell toxicity evaluations was performed on the two generations of an anionic linear-globular dendrimer G1 and G2 (where PEG is the core, and citric acid is the periphery) each of which has a different size, charge, and MW. In vitro cytotoxicity behavior of the dendrimers with the methods like crystal violet staining, methyl thiazolyl tetrazolium (MTT), and lactate dehydrogenase (LDH) assays was analyzed. The cell death mechanisms (apoptosis-necrosis) induced by the dendrimers were also evaluated in HT1080 cell line. The impact of the dendrimers on the release of the pro-inflammatory cytokines like TNF-alpha (tumor necrosis factor alpha) and IL1-beta (interleukin 1 beta) was assessed in THP-1 cell line. Hemolysis assay and coagulation studies such as PT (prothrombin time) and APTT (activated partial thromboplastin time) on human blood samples were conducted to examine the interactions of the dendrimers with such bio-environments. The results of cell cytotoxicity experiments and the amounts of IL1-beta and TNF-alpha secretions from THP-1 cell line were consistent with the hemoglobin release from the erythrocytes and the results gained from the coagulation studies. In fact, no significant harmful effect was observed for the dendrimers up to the concentration of 0.5 mg/ml. Both apoptosis and necrosis were ascribed to cell death. The G1 with more flexibility, less negative charge, and greater poly dispersity in size versus the G2 displayed more toxicity than the G2 at the concentration of 1 mg/ml and above in most of the experiments. As a whole, these results suggest a biocompatible range for these hybrid structures up to the concentration of 0.5 mg/ml. Therefore, the potentiality for these structures to be employed in the

  10. Influence of Surfactant and Lipid Type on the Physicochemical Properties and Biocompatibility of Solid Lipid Nanoparticles

    Directory of Open Access Journals (Sweden)

    Carine Dal Pizzol

    2014-08-01

    Full Text Available Nine types of solid lipid nanoparticle (SLN formulations were produced using tripalmitin (TPM, glyceryl monostearate (GM or stearic acid (SA, stabilized with lecithin S75 and polysorbate 80. Formulations were prepared presenting PI values within 0.25 to 0.30, and the physicochemical properties, stability upon storage and biocompatibility were evaluated. The average particle size ranged from 116 to 306 nm, with a negative surface charge around −11 mV. SLN presented good stability up to 60 days. The SLN manufactured using SA could not be measured by DLS due to the reflective feature of this formulation. However, TEM images revealed that SA nanoparticles presented square/rod shapes with an approximate size of 100 nm. Regarding biocompatibility aspects, SA nanoparticles showed toxicity in fibroblasts, causing cell death, and produced high hemolytic rates, indicating toxicity to red blood cells. This finding might be related to lipid type, as well as, the shape of the nanoparticles. No morphological alterations and hemolytic effects were observed in cells incubated with SLN containing TPM and GM. The SLN containing TPM and GM showed long-term stability, suggesting good shelf-life. The results indicate high toxicity of SLN prepared with SA, and strongly suggest that the components of the formulation should be analyzed in combination rather than separately to avoid misinterpretation of the results.

  11. Influence of surfactant and lipid type on the physicochemical properties and biocompatibility of solid lipid nanoparticles.

    Science.gov (United States)

    Pizzol, Carine Dal; Filippin-Monteiro, Fabíola Branco; Restrepo, Jelver Alexander Sierra; Pittella, Frederico; Silva, Adny Henrique; Alves de Souza, Paula; Machado de Campos, Angela; Creczynski-Pasa, Tânia Beatriz

    2014-08-20

    Nine types of solid lipid nanoparticle (SLN) formulations were produced using tripalmitin (TPM), glyceryl monostearate (GM) or stearic acid (SA), stabilized with lecithin S75 and polysorbate 80. Formulations were prepared presenting PI values within 0.25 to 0.30, and the physicochemical properties, stability upon storage and biocompatibility were evaluated. The average particle size ranged from 116 to 306 nm, with a negative surface charge around -11 mV. SLN presented good stability up to 60 days. The SLN manufactured using SA could not be measured by DLS due to the reflective feature of this formulation. However, TEM images revealed that SA nanoparticles presented square/rod shapes with an approximate size of 100 nm. Regarding biocompatibility aspects, SA nanoparticles showed toxicity in fibroblasts, causing cell death, and produced high hemolytic rates, indicating toxicity to red blood cells. This finding might be related to lipid type, as well as, the shape of the nanoparticles. No morphological alterations and hemolytic effects were observed in cells incubated with SLN containing TPM and GM. The SLN containing TPM and GM showed long-term stability, suggesting good shelf-life. The results indicate high toxicity of SLN prepared with SA, and strongly suggest that the components of the formulation should be analyzed in combination rather than separately to avoid misinterpretation of the results.

  12. Research on the preparation, biocompatibility and bioactivity of magnesium matrix hydroxyapatite composite material.

    Science.gov (United States)

    Linsheng, Li; Guoxiang, Lin; Lihui, Li

    2016-08-12

    In this paper, magnesium matrix hydroxyapatite composite material was prepared by electrophoretic deposition method. The optimal process parameters of electrophoretic deposition were HA suspension concentration of 0.02 kg/L, aging time of 10 days and voltage of 60 V. Animal experiment and SBF immersion experiment were used to test the biocompatibility and bioactivity of this material respectively. The SD rats were divided into control group and implant group. The implant surrounding tissue was taken to do tissue biopsy, HE dyed and organizational analysis after a certain amount of time in the SD rat body. The biological composite material was soaked in SBF solution under homeothermic condition. After 40 days, the bioactivity of the biological composite material was evaluated by testing the growth ability of apatite on composite material. The experiment results showed that magnesium matrix hydroxyapatite biological composite material was successfully prepared by electrophoretic deposition method. Tissue hyperplasia, connective tissue and new blood vessels appeared in the implant surrounding soft tissue. No infiltration of inflammatory cells of lymphocytes and megakaryocytes around the implant was found. After soaked in SBF solution, a layer bone-like apatite was found on the surface of magnesium matrix hydroxyapatite biological composite material. The magnesium matrix hydroxyapatite biological composite material could promot calcium deposition and induce bone-like apatite formation with no cytotoxicity and good biocompatibility and bioactivity.

  13. Biocompatibility and favorable response of mesenchymal stem cells on fibronectin-gold nanocomposites.

    Directory of Open Access Journals (Sweden)

    Huey-Shan Hung

    Full Text Available A simple surface modification method, comprising of a thin coating with gold nanoparticles (AuNPs and fibronectin (FN, was developed to improve the biocompatibility required for cardiovascular devices. The nanocomposites from FN and AuNPs (FN-Au were characterized by the atomic force microscopy (AFM, UV-Vis spectrophotometry (UV-Vis, and Fourier transform infrared spectroscopy (FTIR. The biocompatibility of the nanocomposites was evaluated by the response of monocytes and platelets to the material surface in vitro. FN-Au coated surfaces demonstrated low monocyte activation and platelet activation. The behavior of human umbilical cord-derived mesenchymal stem cells (MSCs on FN-Au was further investigated. MSCs on FN-Au nanocomposites particularly that containing 43.5 ppm of AuNPs (FN-Au 43.5 ppm showed cell proliferation, low ROS generation, as well as increases in the protein expression levels of matrix metalloproteinase-9 (MMP-9 and endothelial nitric oxide synthase (eNOS, which may account for the enhanced MSC migration on the nanocomposites. These results suggest that the FN-Au nanocomposite thin film coating may serve as a potential and simple solution for the surface modification of blood-contacting devices such as vascular grafts.

  14. Biocompatible medical implant materials with binding sites for a biodegradable drug-delivery system

    Directory of Open Access Journals (Sweden)

    Al-Dubai H

    2011-10-01

    Full Text Available Haifa Al-Dubai1, Gisela Pittner1, Fritz Pittner1, Franz Gabor21Max F Perutz Laboratories, Department of Biochemistry, University of Vienna, Vienna, Austria; 2Department of Pharmaceutical Technology and Biopharmaceutics, Faculty of Life Sciences, University of Vienna, Vienna, AustriaAbstract: Feasibility studies have been carried out for development of a biocompatible coating of medical implant materials allowing the binding of biodegradable drug-delivery systems in a way that their reloading might be possible. These novel coatings, able to bind biodegradable nanoparticles, may serve in the long run as drug carriers to mediate local pharmacological activity. After biodegradation of the nanoparticles, the binding sites could be reloaded with fresh drug-delivering particles. As a suitable receptor system for the nanoparticles, antibodies are anchored. The design of the receptor is of great importance as any bio- or chemorecognitive interaction with other components circulating in the blood has to be avoided. Furthermore, the binding between receptor and the particles has to be strong enough to keep them tightly bound during their lifetime, but on the other hand allow reloading after final degradation of the particles. The nanoparticles suggested as a drug-delivery system for medical implants can be loaded with different pharmaceuticals such as antibiotics, growth factors, or immunosuppressives. This concept may enable the changing of medication, even after implantation of the medical device, if afforded by patients’ needs.Keywords: antibody immobilization, biocompatible coating, chitosan nanoparticles, drug targeting, medical device

  15. Preparation and biocompatibility evaluation of pectin and chitosan cryogels for biomedical application.

    Science.gov (United States)

    Konovalova, Mariya V; Markov, Pavel A; Durnev, Eugene A; Kurek, Denis V; Popov, Sergey V; Varlamov, Valery P

    2017-02-01

    Today, there is a need for the development of biomaterials with novel properties for biomedical purposes. The biocompatibility of materials is a key factor in determining its possible use in biomedicine. In this study, composite cryogels were obtained based on pectin and chitosan using ionic cryotropic gelation. For cryogel preparation, apple pectin (AP), Heracleum L. pectin (HP), and chitosan samples with different physical and chemical characteristics were used. The properties of pectin-chitosan cryogels were found to depend on the structural features and physicochemical characteristics of the pectin and chitosan within them. The addition of chitosan to cryogels can increase their mechanical strength, cause change in surface morphology, increase the degradation time, and enhance adhesion to biological tissues. Cryogels based on AP were less immunogenic when compared with cryogels from HP. Cryogels based on AP and HP were hemocompatible and the percentage of red blood cells hemolysis was less than 5%. Unlike cryogels based on HP, which exhibited moderate cytotoxicity, cryogels based on AP exhibited light cytotoxicity. Based on the results of low immunogenicity, light cytotoxicity data as well as a low level of hemolysis of composite cryogels based on AP and chitosan are biocompatible and can potentially be used in biomedicine. © 2016 Wiley Periodicals, Inc. J Biomed Mater Res Part A: 105A: 547-556, 2017.

  16. Phase III study on surface construction and biocompatibility of polymer materials as cardiovascular devices:coagulant and anti-coagulant surface modification

    Institute of Scientific and Technical Information of China (English)

    Chen Bao-lin; Wang Dong-an

    2015-01-01

    BACKGROUND: As the cardiovascular device, biomaterials applied under the blood-contact conditions should have anti-thrombotic, anti-biodegradable and anti-infective properties. OBJECTIVE: To develop novel polymer materials for implantation and intervention in cardiovascular tissue engineering and to explore the biocompatibility, blood compatibility and cytocompatibility of the surface-modified polymer biomaterials based on the coagulant and anti-coagulant coating modification. METHODS:We retrieved PubMed and WanFang databases for relevant articles publishing from 1983 to 2014. The key words were "biocompatibility, blood compatibility, biomedical materials, biomedical polymer materials" in English and Chinese, respectively. Those unrelated, outdated and repetitive papers were excluded. Literatures addressing the blood compatibility of biomedical polymer materials were summarized. RESULTS AND CONCLUSION: The blood-implant interaction and the anti-coagulant surface modification of biomaterials were analyzed. The biocompatibility, blood compatibility and cytocompatibility of the surface-modified polymer biomaterials were determined based on the coagulant and anti-coagulant coating modification. The coagulant and anti-coagulant surface modification of polymer biomaterials and the research on their biocompatibility and endothelial cel compatibility are crucial for developing novel polymer materials for implantation and intervention in cardiovascular tissue engineering. Through in-depth studies of the types and applications of polymer biomaterials, cardiovascular medical devices and implantable soft tissue substitutes, the differences between the surface and the body wil be reflected in the many layers of molecules extending from the surface to the body. Two major factors, surface energy and molecular mobility, determine the body/surface behaviors that include body/surface differences and phase separation. Considering the difference between the body/surface composition

  17. Peripheral white blood cells profile of biodegradable metal implant in mice animal model

    Science.gov (United States)

    Paramitha, Devi; Noviana, Deni; Estuningsih, Sri; Ulum, Mokhamad Fakhrul; Nasution, Ahmad Kafrawi; Hermawan, Hendra

    2015-09-01

    Biocompatibility or safety of the medical device is considered important. It can be determined by blood profile examination. The aim of this study was to assess the biocompatibility of biodegradable metal implant through peripheral white blood cells (WBCs) profile approach. Forty eight male ddy mice were divided into four groups according to the materials implanted: iron wire (Fe), magnesium rod (Mg), stainless steel surgical wire (SS316L) and control with sham (K). Implants were inserted and attached onto the right femoral bone on latero-medial region. In this study, peripheral white blood cells and leukocyte differentiation were the parameters examined. The result showed that the WBCs value of all groups were decreased at the first day after implantation, increased at the 10th day and continued increasing at the 30th day of observation, except Mg group which has decreased. Neutrophil, as an inflammatory cells, was increased at the early weeks and decreased at the day-30 after surgery in all groups. Despite, these values during the observation were still within the normal range. As a conclus ion, biodegradable metal implants lead to an inflammatory reaction, with no adverse effect on WBC value found.

  18. Peripheral white blood cells profile of biodegradable metal implant in mice animal model

    Energy Technology Data Exchange (ETDEWEB)

    Paramitha, Devi; Noviana, Deni, E-mail: deni@ipb.ac.id; Estuningsih, Sri [Faculty of Veterinary Medicine, Bogor Agricultural University (IPB), Bogor (Indonesia); Ulum, Mokhamad Fakhrul [Faculty of Veterinary Medicine, Bogor Agricultural University (IPB), Bogor (Indonesia); Faculty of Biosciences and Medical Engineering, Universiti Teknologi Malaysia (UTM), Johor Bahru (Malaysia); Nasution, Ahmad Kafrawi [Faculty of Biosciences and Medical Engineering, Universiti Teknologi Malaysia (UTM), Johor Bahru (Malaysia); Faculty of Engineering, Muhammadiyah University of Riau (UMRI), Pekanbaru (Indonesia); Hermawan, Hendra [Department of Mining, Metallurgical and Materials Engineering & CHU de Québec Research Center, Laval University (ULaval) (Canada)

    2015-09-30

    Biocompatibility or safety of the medical device is considered important. It can be determined by blood profile examination. The aim of this study was to assess the biocompatibility of biodegradable metal implant through peripheral white blood cells (WBCs) profile approach. Forty eight male ddy mice were divided into four groups according to the materials implanted: iron wire (Fe), magnesium rod (Mg), stainless steel surgical wire (SS316L) and control with sham (K). Implants were inserted and attached onto the right femoral bone on latero-medial region. In this study, peripheral white blood cells and leukocyte differentiation were the parameters examined. The result showed that the WBCs value of all groups were decreased at the first day after implantation, increased at the 10th day and continued increasing at the 30th day of observation, except Mg group which has decreased. Neutrophil, as an inflammatory cells, was increased at the early weeks and decreased at the day-30 after surgery in all groups. Despite, these values during the observation were still within the normal range. As a conclus ion, biodegradable metal implants lead to an inflammatory reaction, with no adverse effect on WBC value found.

  19. Corrosion resistance and biocompatibility of titanium surface coated with amorphous tantalum pentoxide

    Energy Technology Data Exchange (ETDEWEB)

    Sun, Ying-Sui [Department of Oral Biology, National Yang-Ming University, Taipei, Taiwan (China); Chang, Jean-Heng [Dental Department, Cheng Hsin General Hospital, Taipei, Taiwan (China); Huang, Her-Hsiung, E-mail: hhhuang@ym.edu.tw [Department of Dentistry, National Yang-Ming University, Taipei, Taiwan (China); Department of Dentistry, Taipei City Hospital, Taipei, Taiwan (China); Department of Stomatology, Taipei Veterans General Hospital, Taipei, Taiwan (China)

    2013-01-01

    Tantalum pentoxide (Ta{sub 2}O{sub 5}) possesses good corrosion resistance and biocompatibility. This study aimed to improve the corrosion resistance and biocompatibility of titanium (Ti) by coating it with an amorphous Ta{sub 2}O{sub 5} surface layer. An amorphous Ta{sub 2}O{sub 5} layer was prepared on the Ti surface using a simple hydrolysis–condensation process at room temperature. The surface characteristics of the test specimens were analyzed using X-ray photoelectron spectroscopy, glancing angle X-ray diffraction, field emission scanning electron microscopy, and contact angle measurements. The corrosion resistance of the test specimens was evaluated from the potentiodynamic polarization curves and ion release measurements in simulated blood plasma (SBP). The biocompatibility of the test specimens was evaluated in terms of the protein (albumin) adsorption, cell adhesion, and cell growth of human bone marrow mesenchymal stem cells (hBMSCs). The amorphous Ta{sub 2}O{sub 5} layer with a porous micro-/nano-scale topography, which was deposited on the Ti surface using a simple hydrolysis–condensation process, increased the corrosion resistance (i.e., increased the corrosion potential and decreased the anodic current and ion release) of the Ti in the SBP and improved the surface wettability, albumin adsorption, and cell adhesion. We conclude that the presence of an amorphous Ta{sub 2}O{sub 5} layer on the Ti surface increased the corrosion resistance and biocompatibility of Ti. - Highlights: ► Amorphous Ta{sub 2}O{sub 5} layer was coated on Ti using simple hydrolysis–condensation process. ► Ta{sub 2}O{sub 5} surface layer showed a micro-/nano-scale porous topography. ► Ta{sub 2}O{sub 5} layer enhanced wettability and corrosion resistance of Ti. ► Ta{sub 2}O{sub 5} layer enhanced protein adsorption, cell adhesion, and cell proliferation of Ti.

  20. Influence of Cu content on the cell biocompatibility of Ti–Cu sintered alloys

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, Erlin, E-mail: zhangel@atm.neu.edu.cn [Key Lab. for Anisotropy and Texture of Materials, Education Ministry of China, Northeastern University, Shenyang 110819 (China); Jiamusi University, Jiamusi 154007 (China); Zheng, Lanlan [Jiamusi University, Jiamusi 154007 (China); Liu, Jie [Key Lab. for Anisotropy and Texture of Materials, Education Ministry of China, Northeastern University, Shenyang 110819 (China); Dept. of Prosthodontics, The Affiliated Hospital of Medical College, Qingdao University, Qingdao 266003 (China); Bai, Bing [Dept. of Prosthodontics, School of Stomatology, China Medical University, Liaoning Institute of Dental Research, Shenyang 110001 (China); Liu, Cong [Jiamusi University, Jiamusi 154007 (China)

    2015-01-01

    The cell toxicity and the cell function of Ti–Cu sintered alloys with different Cu contents (2, 5, 10 and 25 wt.%, respectively) have been investigated in comparison with commercial pure titanium in order to assess the influence of Cu content on the cell biocompatibility of the Ti–Cu alloys. The cytotoxicity was studied by examining the MG63 cell response by CCK8 assessment. The cell morphology was evaluated by acridine orange/ethidium bromide (AO/EB) fluorescence and observed under scanning electronic microscopy (SEM). The cell function was monitored by measuring the AKP activity. It has been shown by the AO/EB morphology results that the cell death on both cp-Ti sample and Ti–Cu samples is due to apoptosis rather than necrosis. Although more apoptotic cells were found on the Ti–2Cu and Ti–5Cu samples, no evidence of Cu content dependent manner of apoptosis has been found. SEM observation indicated very good cell adhesion and spread on the cp-Ti sample and the Ti–Cu samples with different Cu contents. CCK8 results displayed that increase in the Cu content in Ti–Cu alloys does not bring about any difference in the cell viability. In addition, AKP test results indicated that no difference in the differentiation of MG63 was found between the cp-Ti and the Ti–Cu samples and among the Ti–Cu samples. All results indicated that Ti–Cu alloys exhibit very good cell biocompatibility and the Cu content up to 25 wt.% in the Ti–Cu alloys has no influence on the cell proliferation and differentiation. - Highlights: • The effect of Cu content on the cell biocompatibility has been investigated. • Cu content shows no influence on the cell proliferation. • Cu content shows no effect on the cell differentiation.

  1. Natural polysaccharide functionalized gold nanoparticles as biocompatible drug delivery carrier.

    Science.gov (United States)

    Pooja, Deep; Panyaram, Sravani; Kulhari, Hitesh; Reddy, Bharathi; Rachamalla, Shyam S; Sistla, Ramakrishna

    2015-09-01

    Biocompatibility is one of the major concerns with inorganic nanoparticles for their applications as drug delivery system. Natural compounds such as sugars, hydrocolloids and plant extracts have shown potential for the green synthesis of biocompatible gold nanoparticles. In this study, we report the synthesis of gum karaya (GK) stabilized gold nanoparticles (GKNP) and the application of prepared nanoparticles in the delivery of anticancer drugs. GKNP were characterized using different analytical techniques. GKNP exhibited high biocompatibility during cell survival study against CHO normal ovary cells and A549 human non-small cell lung cancer cells and during hemolytic toxicity studies. Gemcitabine hydrochloride (GEM), an anticancer drug, was loaded on the surface of nanoparticles with 19.2% drug loading efficiency. GEM loaded nanoparticles (GEM-GNP) showed better inhibition of growth of cancer cells in anti-proliferation and clonogenic assays than native GEM. This effect was correlated with higher reactive oxygen species generation by GEM-GNP in A549 cells than native GEM. In summary, GK has significant potential in the synthesis of biocompatible gold nanoparticles that could be used as prospective drug delivery carrier for anticancer drugs.

  2. In vivo biocompatibility of nanostructured Chitosan/Peo membranes

    Directory of Open Access Journals (Sweden)

    V.A.S. Vulcani

    2015-08-01

    Full Text Available Electrospinning is a technique that allows the preparation of nanofibers from various materials. Chitosan is a natural and abundant easily obtained polymer, which, in addition to those features, proved to be biocompatible. This work used nanostructured chitosan and polyoxyethylene membranes as subcutaneous implants in Wistar rats to evaluate the biocompatibility of the material. Samples of the material and tissues adjacent to the implant were collected 7, 15, 30, 45 and 60 days post-implantation. Macroscopic integration of the material to the tissues was observed in the samples and slides for histopathological examination that were prepared. It was noticed that the material does not stimulate the formation of adherences to the surrounding tissues and that there is initial predominance of neutrophilia and lymphocytosis, with a declining trend according to the increase of time, featuring a non-persistent acute inflammatory process. However, the material showed fast degradation, impairing the macroscopic observation after fifteen days of implantation. It was concluded that the material is biocompatible and that new studies should be conducted, modifying the time of degradation by changes in obtaining methods and verifying the biocompatibility in specific tissues for biomedical applications.

  3. Chemical design of biocompatible iron oxide nanoparticles for medical applications.

    Science.gov (United States)

    Ling, Daishun; Hyeon, Taeghwan

    2013-05-27

    Iron oxide nanoparticles are one of the most versatile and safe nanomaterials used in medicine. Recent progress in nanochemistry enables fine control of the size, crystallinity, uniformity, and surface properties of iron oxide nanoparticles. In this review, the synthesis of chemically designed biocompatible iron oxide nanoparticles with improved quality and reduced toxicity is discussed for use in diverse biomedical applications.

  4. Synthesis and characterization of biocompatible hydroxyapatite coated ferrite

    Indian Academy of Sciences (India)

    S Deb; J Giri; S Dasgupta; D Datta; D Bahadur

    2003-12-01

    Ferrite particles coated with biocompatible phases can be used for hyperthermia treatment of cancer. We have synthesized substituted calcium hexaferrite, which is not stable on its own but is stabilized with small substitution of La. Hexaferrite of chemical composition (CaO)0.75(La2O3)0.20(Fe2O3)6 was prepared using citrate gel method. Hydroxyapatite was prepared by precipitating it from aqueous solution of Ca(NO3)2 and (NH4)2HPO4 maintaining pH above 11. Four different methods were used for coating of hydroxyapatite on ferrite particles. SEM with EDX and X-ray diffraction analysis shows clear evidence of coating of hydroxy-apatite on ferrite particles. These coated ferrite particles exhibited coercive field up to 2 kOe, which could be made useful for hysteresis heating in hyperthermia. Studies by culturing BHK-21 cells and WBC over the samples show evidence of biocompatibility. SEM micrographs and cell counts give clear indication of cell growth on the surface of the sample. Finally coated ferrite particle was implanted in Kasaulli mouse to test its biocompatibility. The magnetic properties and biocompatibility studies show that these hydroxyapatite coated ferrites could be useful for hyperthermia.

  5. Biocompatibility of mineral trioxide aggregate and three new endodontic cements: An animal study

    Directory of Open Access Journals (Sweden)

    Mohammad-Ghasem Aminozarbian

    2012-01-01

    Conclusion: According to the results of the current study, biocompatibility of CAAC and WOLCA cement were comparable with that of MTA, but CAAC Plus induced an inflammatory response higher than MTA, therefore is not biocompatible.

  6. Ambulatory Blood Pressure Monitoring (ABPM) as the reference standard for diagnosis of hypertension and assessment of vascular risk in adults.

    Science.gov (United States)

    Hermida, Ramón C; Smolensky, Michael H; Ayala, Diana E; Portaluppi, Francesco

    2015-01-01

    New information has become available since the ISC, AAMCC, and SECAC released their first extensive guidedelines to improve the diagnosis and treatment of adult arterial hypertension. A critical assessment of evidence and a comparison of what international guidelines now propose are the basis for the following statements, which update the recommendations first issued in 2013. Office blood pressure (BP) measurements should no longer be considered to be the "gold standard" for the diagnosis of hypertension and assessment of cardiovascular risk. Relying on office BP, even when supplemented with at-home wake-time self-measurements, to identify high-risk individuals, disregarding circadian BP patterning and asleep BP level, leads to potential misclassification of 50% of all evaluated persons. Accordingly, ambulatory BP monitoring is the recommended reference standard for the diagnosis of true hypertension and accurate assessment of cardiovascular risk in all adults ≥18 yrs of age, regardless of whether office BP is normal or elevated. Asleep systolic BP mean is the most significant independent predictor of cardiovascular events. The sleep-time relative SBP decline adds prognostic value to the statistical model that already includes the asleep systolic BP mean and corrected for relevant confounding variables. Accordingly, the asleep systolic BP mean is the recommended protocol to diagnose hypertension, assess cardiovascular risk, and predict cardiovascular event-free interval. In men, and in the absence of compelling clinical conditions, reference thresholds for diagnosing hypertension are 120/70 mmHg for the asleep systolic/diastolic BP means derived from ambulatory BP monitoring. However, in women, in the absence of complicating co-morbidities, the same thresholds are lower by 10/5 mmHg, i.e., 110/65 mmHg for the asleep means. In high-risk patients, including those diagnosed with diabetes or chronic kidney disease, and/or those having experienced past

  7. Biocompatibility of acrylic resin after being soaked in sodium hypochlorite

    Directory of Open Access Journals (Sweden)

    Nike Hendrijatini

    2009-06-01

    Full Text Available Background: Acrylic resin as basic material for denture will stay on oral mucosa for a very long time. The polymerization of acrylic resin can be performed by conventional method and microwave, both produce different residual monomer at different toxicity. Acrylic resin can absorb solution, porous and possibly absorb disinfectantt as well, that may have toxic reaction with the tissue. Sodium Hypochlorite as removable denture disinfectant can be expected to be biocompatible to human body. The problem is how biocompatible acrylic resin which has been processed by conventional method and microwave method after being soaked in sodium hypochlorite solution. Purpose: The aim of this study was to understand in vitro biocompatibility of acrylic resin which has polimerated by conventional method and microwave after being soaked in sodium hypochlorite using tissue culture. Methods: Four groups of acrylic resin plate were produced, the first group was acrylic resin plate with microwave polymeration and soaked in sodium hypochlorite, the second group was acrylic resin plate with microwave polymeration but not soaked, the thirdwas one with conventional method and soaked and the last group was one with conventional method but not soaked, and in 1 control group. Each group consists of 7 plates. Biocompatibility test was performed in-vitro on each material using fibroblast tissue culture (BHK-21 cell-line. Result: The percentage between living cells and dead cells from materials which was given acrylic plate was wounted. The data was analyzed statistically with T test. Conclusion: The average value of living cells is higher in acrylic resin poimerization using microwave method compared to conventional method, in both soaked and non soaked (by sodium hypochlorite group. This means that sodium hypochlorite 0.5% was biocompatible to the mouth mucosa as removable denture disinfectant for 10 minutes soaking and washing afterwards.

  8. Increased peritoneal permeability at peritoneal dialysis initiation is a potential cardiovascular risk in patients using biocompatible peritoneal dialysis solution.

    Science.gov (United States)

    Hamasaki, Yoshifumi; Doi, Kent; Tanaka, Mototsugu; Kume, Haruki; Ishibashi, Yoshitaka; Enomoto, Yutaka; Fujita, Toshiro; Homma, Yukio; Nangaku, Masaomi; Noiri, Eisei

    2014-11-01

    Cardiovascular disease is a frequent cause of death in peritoneal dialysis patients. Biocompatible peritoneal dialysis solutions with neutral pH have been anticipated to reduce cardiovascular disease more than conventional peritoneal dialysis solutions with low pH, but it remains unclear which factors at peritoneal dialysis initiation increase cardiovascular risk in patients using biocompatible peritoneal dialysis solutions. This study was undertaken to investigate which clinical factors at peritoneal dialysis initiation, including peritoneal transport status, are associated with cardiovascular event in patients using biocompatible peritoneal dialysis solution. This retrospective cohort study of peritoneal dialysis patients using biocompatible solutions with neutral pH assessed relations of clinical parameters at peritoneal dialysis initiation to cardiovascular event during the subsequent five years. Of 102 patients who started peritoneal dialysis, cardiovascular event occurred in 18. Age, history of cardiovascular disease before peritoneal dialysis initiation, hemoglobin, serum albumin, C-reactive protein, peritoneal permeability defined by the ratio of dialysate to plasma creatinine concentration at 4 hr (D/Pcre) in peritoneal equilibration test (PET), number of patients in each PET category defined by D/Pcre, and peritoneal protein clearance significantly differed between patients with and without cardiovascular event. For patients divided according to PET category using Kaplan-Meier method, the group of high average to high peritoneal transporters exhibited significantly high incidence of cardiovascular event and mortality compared with the groups of low and low-average peritoneal transporters (Log rank; p=0.0003 and 0.005, respectively). A Cox proportional hazards model showed independent association of PET category classification with cardiovascular event. Peritoneal permeability expressed as PET category at peritoneal dialysis initiation is an independent

  9. Blood Basics

    Science.gov (United States)

    ... of ASH ASH Meeting on Hematologic Malignancies Consultative Hematology Course ASH Meeting on Lymphoma Biology ASH Workshop on Genome Editing Publications Blood The Hematologist ASH Clinical News ASH Self-Assessment Program Hematology , ASH Education Program About Awards Membership ASH Foundation ...

  10. Blood Clots

    Science.gov (United States)

    ... of ASH ASH Meeting on Hematologic Malignancies Consultative Hematology Course ASH Meeting on Lymphoma Biology ASH Workshop on Genome Editing Publications Blood The Hematologist ASH Clinical News ASH Self-Assessment Program Hematology , ASH Education Program About Awards Membership ASH Foundation ...

  11. Contribution of spiral artery blood flow changes assessed by transvaginal color Doppler sonography for predicting endometrial pathologies

    Directory of Open Access Journals (Sweden)

    Suna Kabil Kucur

    2013-01-01

    Full Text Available ive: To investigate the diagnostic value of blood flow measurements in spiral artery by transvaginal color Doppler sonography (CDS in predicting endometrial pathologies.Methods: Ninety-seven patients presenting with abnormal uterine bleeding and requiring endometrial assessment were included in this prospective observational study. Endometrial thickness, structure and echogenicity were recorded. Pulsatility index (PI and resistive index (RI of the spiral artery were measured by transvaginal CDS. Endometrial sampling was performed for all subjects. Sonographic and hystopathologic findings were compared.Results: The histopathological diagnoses were as follows; 39 cases (40.2% endometrial polyp, 9 cases (9.3% endometrial hyperplasia, 10 cases (10.3 submucous myoma, 7 cases (7.2% endometrium cancer, and 32 cases (33% nonspecific findings. The spiral artery PI in endometrium cancer group was highly significantly lower than other groups (p<0.01. The spiral artery RI was also significantly lower in the patients with malignant histology (p<0.05. Conclusion: Endometrial pathologies are associated significantly with endometrial spiral artery Doppler changes.Key words: Spiral artery, Doppler ultrasonography, endometrium

  12. Alterations of Regional Cerebral Blood Flow in Tinnitus Patients as Assessed Using Single-Photon Emission Computed Tomography.

    Directory of Open Access Journals (Sweden)

    Takashi Ueyama

    Full Text Available Tinnitus is the perception of phantom sound without an external auditory stimulus. Using neuroimaging techniques, such as positron emission tomography, electroencephalography, magnetoencephalography, and functional magnetic resonance imaging (fMRI, many studies have demonstrated that abnormal functions of the central nervous system are closely associated with tinnitus. In our previous research, we reported using resting-state fMRI that several brain regions, including the rectus gyrus, cingulate gyrus, thalamus, hippocampus, caudate, inferior temporal gyrus, cerebellar hemisphere, and medial superior frontal gyrus, were associated with tinnitus distress and loudness. To reconfirm these results and probe target regions for repetitive transcranial magnetic stimulation (rTMS, we investigated the regional cerebral blood flow (rCBF between younger tinnitus patients (<60 years old and the age-matched controls using single-photon emission computed tomography and easy Z-score imaging system. Compared with that of controls, the rCBF of tinnitus patients was significantly lower in the bilateral medial superior frontal gyri, left middle occipital gyrus and significantly higher in the bilateral cerebellar hemispheres and vermis, bilateral middle temporal gyri, right fusiform gyrus. No clear differences were observed between tinnitus patients with normal and impaired hearing. Regardless of the assessment modality, similar brain regions were identified as characteristic in tinnitus patients. These regions are potentially involved in the pathophysiology of chronic subjective tinnitus.

  13. Ex vivo Evans blue assessment of the blood brain barrier in three breast cancer brain metastasis models.

    Science.gov (United States)

    Do, John; Foster, Deshka; Renier, Corinne; Vogel, Hannes; Rosenblum, Sahar; Doyle, Timothy C; Tse, Victor; Wapnir, Irene

    2014-02-01

    The limited entry of anticancer drugs into the central nervous system represents a special therapeutic challenge for patients with brain metastases and is primarily due to the blood brain barrier (BBB). Albumin-bound Evans blue (EB) dye is too large to cross the BBB but can grossly stain tissue blue when the BBB is disrupted. The course of tumor development and the integrity of the BBB were studied in three preclinical breast cancer brain metastasis (BCBM) models. A luciferase-transduced braintropic clone of MDA-231 cell line was used. Nude mice were subjected to stereotactic intracerebral inoculation, mammary fat pad-derived tumor fragment implantation, or carotid artery injections. EB was injected 30 min prior to euthanasia at various timepoints for each of the BCBM model animals. Serial bioluminescent imaging demonstrated exponential tumor growth in all models. Carotid BCBM appeared as diffuse multifocal cell clusters. EB aided the localization of metastases ex vivo. Tumor implants stained blue at 7 days whereas gross staining was not evident until day 14 in the stereotactic model and day 28 for the carotid model. EB assessment of the integrity of the BBB provides useful information relevant to drug testing in preclinical BCBM models.

  14. Assessment of reduced-order unscented Kalman filter for parameter identification in 1-dimensional blood flow models using experimental data.

    Science.gov (United States)

    Caiazzo, A; Caforio, Federica; Montecinos, Gino; Muller, Lucas O; Blanco, Pablo J; Toro, Eluterio F

    2016-10-25

    This work presents a detailed investigation of a parameter estimation approach on the basis of the reduced-order unscented Kalman filter (ROUKF) in the context of 1-dimensional blood flow models. In particular, the main aims of this study are (1) to investigate the effects of using real measurements versus synthetic data for the estimation procedure (i.e., numerical results of the same in silico model, perturbed with noise) and (2) to identify potential difficulties and limitations of the approach in clinically realistic applications to assess the applicability of the filter to such setups. For these purposes, the present numerical study is based on a recently published in vitro model of the arterial network, for which experimental flow and pressure measurements are available at few selected locations. To mimic clinically relevant situations, we focus on the estimation of terminal resistances and arterial wall parameters related to vessel mechanics (Young's modulus and wall thickness) using few experimental observations (at most a single pressure or flow measurement per vessel). In all cases, we first perform a theoretical identifiability analysis on the basis of the generalized sensitivity function, comparing then the results owith the ROUKF, using either synthetic or experimental data, to results obtained using reference parameters and to available measurements.

  15. ASSESSMENT OF THE RESIDUAL TUMOR IN PATIENTS WITH MULTIPLE MYELOMA BASED ON THE ANALYSIS OF THE FREE LIGHT CHAINS OF IMMUNOGLOBULINS IN BLOOD SERUM

    Directory of Open Access Journals (Sweden)

    T. A. Мitina

    2013-01-01

    Full Text Available Efficiency of the multiple myeloma treatment with chemotherapy including bortezomib was assessed based on determination of the level of immunoglobulin free light chains in blood serum. The method enables estimation of changes in kinetic parameters of the residual tumor, detection of the disease course prognosis, and the choice of the optimal approach to the disease therapy.

  16. Classification of positive blood cultures: computer algorithms versus physicians' assessment - development of tools for surveillance of bloodstream infection prognosis using population-based laboratory databases

    Directory of Open Access Journals (Sweden)

    Gradel Kim O

    2012-09-01

    Full Text Available Abstract Background Information from blood cultures is utilized for infection control, public health surveillance, and clinical outcome research. This information can be enriched by physicians’ assessments of positive blood cultures, which are, however, often available from selected patient groups or pathogens only. The aim of this work was to determine whether patients with positive blood cultures can be classified effectively for outcome research in epidemiological studies by the use of administrative data and computer algorithms, taking physicians’ assessments as reference. Methods Physicians’ assessments of positive blood cultures were routinely recorded at two Danish hospitals from 2006 through 2008. The physicians’ assessments classified positive blood cultures as: a contamination or bloodstream infection; b bloodstream infection as mono- or polymicrobial; c bloodstream infection as community- or hospital-onset; d community-onset bloodstream infection as healthcare-associated or not. We applied the computer algorithms to data from laboratory databases and the Danish National Patient Registry to classify the same groups and compared these with the physicians’ assessments as reference episodes. For each classification, we tabulated episodes derived by the physicians’ assessment and the computer algorithm and compared 30-day mortality between concordant and discrepant groups with adjustment for age, gender, and comorbidity. Results Physicians derived 9,482 reference episodes from 21,705 positive blood cultures. The agreement between computer algorithms and physicians’ assessments was high for contamination vs. bloodstream infection (8,966/9,482 reference episodes [96.6%], Kappa = 0.83 and mono- vs. polymicrobial bloodstream infection (6,932/7,288 reference episodes [95.2%], Kappa = 0.76, but lower for community- vs. hospital-onset bloodstream infection (6,056/7,288 reference episodes [83.1%], Kappa = 0.57 and

  17. Hazard effects of nanoparticles in central nervous system: Searching for biocompatible nanomaterials for drug delivery.

    Science.gov (United States)

    Leite, Paulo Emílio Corrêa; Pereira, Mariana Rodrigues; Granjeiro, José Mauro

    2015-10-01

    Nanostructured materials are widely used in many applications of industry and biomedical fields. Nanoparticles emerges as potential pharmacological carriers that can be applied in the regenerative medicine, diagnosis and drug delivery. Different types of nanoparticles exhibit ability to cross the brain blood barrier (BBB) and accumulate in several brain areas. Then, efforts have been done to develop safer nanocarrier systems to treat disorders of central nervous system (CNS). However, several in vitro and in vivo studies demonstrated that nanoparticles of different materials exhibit a wide range of neurotoxic effects inducing neuroinflammation and cognitive impairment. For this reason, polymeric nanoparticles arise as a promisor alternative due to their biocompatible and biodegradable properties. After an overview of CNS location and neurotoxic effects of translocated nanoparticles, this review addresses the use of polymeric nanoparticles to the treatment of neuroinfectious diseases, as acquired immunodeficiency syndrome (AIDS) and meningitis.

  18. Deposition, characterization, and in vivo performance of parylene coating on general-purpose silicone for examining potential biocompatible surface modifications

    Energy Technology Data Exchange (ETDEWEB)

    Chou, Chia-Man [Division of Pediatric Surgery, Department of Surgery, Taichung Veterans General Hospital, 160, Sec. 3, Taichung Port Rd., Taichung 40705, Taiwan, ROC (China); Department of Medicine, National Yang-Ming University, 155, Sec. 2, Linong Street, Taipei 11221, Taiwan, ROC (China); Shiao, Chiao-Ju [Department of Materials Science and Engineering, Feng Chia University, 100, Wen-Hwa Rd., Taichung 40724, Taiwan, ROC (China); Chung, Chi-Jen, E-mail: cjchung@seed.net.tw [Department of Dental Technology and Materials Science, Central Taiwan University of Science and Technology, 666 Buzih Rd., Beitun District, Taichung 40601, Taiwan, ROC (China); He, Ju-Liang [Department of Materials Science and Engineering, Feng Chia University, 100, Wen-Hwa Rd., Taichung 40724, Taiwan, ROC (China)

    2013-12-31

    In this study, a thorough investigation of parylene coatings was conducted, as follows: microstructure (i.e., X-ray diffractometer (XRD) and cold field emission scanning electron microscope (FESEM)), mechanical property (i.e., pencil hardness and cross-cut adhesion test), surface property (i.e., water contact angle measurement, IR, and X-ray photoelectron spectroscopy (XPS)), and biocompatibility tests (i.e., fibroblast cell culture, platelet adhesion, and animal studies). The results revealed that parylene, a crystalline and brittle coating, exhibited satisfactory film adhesion and relative hydrophobicity, thereby contributing to its effective barrier properties. Fibroblast cell culturing on the parylene-deposited specimen demonstrated improved cell proliferation and equivalent to or superior blood compatibility than that of the medical-grade silicone (currently used clinically). In the animal study, parylene coatings exhibited similar subcutaneous inflammatory reactions compared with the medical-grade silicone. Both in vitro and in vivo tests demonstrated the satisfactory biocompatibility of parylene coatings. - Highlights: • A complete investigation to identify the characteristics of parylene coatings on general-purpose silicones. • Microstructures, surface properties and mechanical properties of parylene coatings were examined. • In vitro (Cell culture, platelet adhesion) tests and animal studies revealed satisfactory biocompatibility. • An alternative of medical-grade silicones is expected to be obtained.

  19. Surface construction and biocompatibility of polymeric used for cardiovascular medical device○

    Institute of Scientific and Technical Information of China (English)

    Chen Bao-lin; Wang Dong-an

    2013-01-01

    BACKGROUND:Biomaterials for the treatment of cardiovascular diseases must have anti-thrombotic, anti-biodegradability and anti-infective ability in the blood-contact condition. OBJECTIVE:To investigate the biocompatibility, blood compatibility and cytocompatibility of new implantable (interfered) polymer material (surface) used in cardiovascular tissue engineering. METHODS:The PubMed database and Wanfang database were retrieved for the related articles from 1967 to 2012 with the key words of“biocompatibility, lood compatibility, biomedical materials, biomedical polymer materials”. RESUTLS AND CONCLUSION:The graft copolymer surface and a block copolymer surfactant that can be used as biological materials were in-depth analyzed though analyzing the design requirements of type, application, cardiovascular medical devices and implantable soft tissue substitutes of polymeric biomaterials used for cardiovascular medicine. The results showed that the difference between the surface and noumenon wil be reflected on many molecular layers that extended from the surface to the noumenon, while the two main factors of surface energy and molecular motion determined the noumenon/surface behavior including the noumenon/surface difference and surface phase separation. If the understanding of the noumenon/surface consisting difference should be taking into consideration, the other determinant should be added too, that was the crystal ization behavior of each competent. If the one of the components contained in the graft copolymer surface and a block copolymer surfactant had higher crystal inity, the other components wil be squeezed out;crystal ization could also hindered the motion and diffusion of molecules, and eventual y, the incompatibility degree of two components of copolymers wil affect the phase separation tendency in the noumenon and surface layers.

  20. Biocompatible silicon wafer bonding for biomedical microdevices

    Science.gov (United States)

    Hansford, Derek; Desai, Tejal A.; Tu, Jay K.; Ferrari, Mauro

    1998-03-01

    In this paper,several candidate bonding materials are reviewed for use in biomedical microdevices. These include poly propylmethacrylate (PPMA), poly methylmethacrylate (PMMA), a copolymer of poly methacrylate and two types of silicone gels. They were evaluated based on their cytotoxicity and bond strength, as well as several other qualitative assessments. The cytotoxicity was determined through a cell growth assay protocol in which cells were grown on the various substrate and their growth was compared to cells grown on control substrate. The adhesive strength was assessed by using a pressurized plate test in which the adhesive interface was pressurized to failure. All of the substrate were found to be non-cytotoxic in an inert manner except for the industrial silicone adhesive gel. The adhesive strengths of the various materials are compared to each other and to previously published adhesive strengths. All of the materials were found to have a sufficient bonding strength for biomedical applications, but several other factors were determined that limit the use of each material.

  1. Comparison of blood aminotransferase methods for assessment of myopathy and hepatopathy in Florida manatees (Trichechus manatus latirostris)

    Science.gov (United States)

    Harr, K.E.; Allison, K.; Bonde, R.K.; Murphy, D.; Harvey, J.W.

    2008-01-01

    Muscle injury is common in Florida manatees (Trichechus manatus latirostris). Plasma aspartate amino-transferase (AST) is frequently used to assess muscular damage in capture myopathy and traumatic injury. Therefore, accurate measurement of AST and alanine aminotransferase (ALT) is important in managed, free-ranging animals, as well as in those rehabilitating from injury. Activities of these enzymes, however, are usually not increased in manatees with either acute or chronic muscle damage, despite marked increases in plasma creatine kinase activity. It is hypothesized that this absence of response is due to apoenzymes in the blood not detected by commonly used veterinary assays. Addition of coenzyme pyridoxal-5-phosphate (P5P or vitamin B6) should, therefore, result in higher measured enzyme activities. The objective of this study was to determine the most accurate, precise, and diagnostically useful method for aminotransferase measurement in manatees that can be used in veterinary practices and diagnostic laboratories. Additionally, appropriate collection and storage techniques were assessed. The use of an optimized commercial wet chemical assay with 100 ??mol P5P resulted in a positive bias of measured enzyme activities in a healthy population of animals. However, AST and ALT were still much lower than that typically observed in domestic animals and should not be used alone in the assessment of capture myopathy and muscular trauma. Additionally, the dry chemistry analyzer, typically used in clinics, reported significantly higher and less precise AST and ALT activities with poor correlation to those measured with wet chemical methods found in diagnostic laboratories. Therefore, these results cannot be clinically compared. Overall, the optimized wet chemical method was the most precise and diagnostically useful measurement of aminotransferase in samples. Additionally, there was a statistically significant difference between paired serum and plasma measurement

  2. Hypertension Canada's 2016 Canadian Hypertension Education Program Guidelines for Blood Pressure Measurement, Diagnosis, Assessment of Risk, Prevention, and Treatment of Hypertension.

    Science.gov (United States)

    Leung, Alexander A; Nerenberg, Kara; Daskalopoulou, Stella S; McBrien, Kerry; Zarnke, Kelly B; Dasgupta, Kaberi; Cloutier, Lyne; Gelfer, Mark; Lamarre-Cliche, Maxime; Milot, Alain; Bolli, Peter; Tremblay, Guy; McLean, Donna; Tobe, Sheldon W; Ruzicka, Marcel; Burns, Kevin D; Vallée, Michel; Prasad, G V Ramesh; Lebel, Marcel; Feldman, Ross D; Selby, Peter; Pipe, Andrew; Schiffrin, Ernesto L; McFarlane, Philip A; Oh, Paul; Hegele, Robert A; Khara, Milan; Wilson, Thomas W; Penner, S Brian; Burgess, Ellen; Herman, Robert J; Bacon, Simon L; Rabkin, Simon W; Gilbert, Richard E; Campbell, Tavis S; Grover, Steven; Honos, George; Lindsay, Patrice; Hill, Michael D; Coutts, Shelagh B; Gubitz, Gord; Campbell, Norman R C; Moe, Gordon W; Howlett, Jonathan G; Boulanger, Jean-Martin; Prebtani, Ally; Larochelle, Pierre; Leiter, Lawrence A; Jones, Charlotte; Ogilvie, Richard I; Woo, Vincent; Kaczorowski, Janusz; Trudeau, Luc; Petrella, Robert J; Hiremath, Swapnil; Drouin, Denis; Lavoie, Kim L; Hamet, Pavel; Fodor, George; Grégoire, Jean C; Lewanczuk, Richard; Dresser, George K; Sharma, Mukul; Reid, Debra; Lear, Scott A; Moullec, Gregory; Gupta, Milan; Magee, Laura A; Logan, Alexander G; Harris, Kevin C; Dionne, Janis; Fournier, Anne; Benoit, Geneviève; Feber, Janusz; Poirier, Luc; Padwal, Raj S; Rabi, Doreen M

    2016-05-01

    Hypertension Canada's Canadian Hypertension Education Program Guidelines Task Force provides annually updated, evidence-based recommendations to guide the diagnosis, assessment, prevention, and treatment of hypertension. This year, we present 4 new recommendations, as well as revisions to 2 previous recommendations. In the diagnosis and assessment of hypertension, automated office blood pressure, taken without patient-health provider interaction, is now recommended as the preferred method of measuring in-office blood pressure. Also, although a serum lipid panel remains part of the routine laboratory testing for patients with hypertension, fasting and nonfasting collections are now considered acceptable. For individuals with secondary hypertension arising from primary hyperaldosteronism, adrenal vein sampling is recommended for those who are candidates for potential adrenalectomy. With respect to the treatment of hypertension, a new recommendation that has been added is for increasing dietary potassium to reduce blood pressure in those who are not at high risk for hyperkalemia. Furthermore, in selected high-risk patients, intensive blood pressure reduction to a target systolic blood pressure ≤ 120 mm Hg should be considered to decrease the risk of cardiovascular events. Finally, in hypertensive individuals with uncomplicated, stable angina pectoris, either a β-blocker or calcium channel blocker may be considered for initial therapy. The specific evidence and rationale underlying each of these recommendations are discussed. Hypertension Canada's Canadian Hypertension Education Program Guidelines Task Force will continue to provide annual updates.

  3. Enhanced biocompatibility and osseointegration of calcium titanate coating on titanium screws in rabbit femur.

    Science.gov (United States)

    Wang, Zi-Li; He, Rong-Zhen; Tu, Bin; Cao, Xu; He, Jin-Shen; Xia, Han-Song; Liang, Chi; Zou, Min; Wu, Song; Wu, Zhen-Jun; Xiong, Kun

    2017-06-01

    This study aimed to examine the biocompatibility of calcium titanate (CaTiO3) coating prepared by a simplified technique in an attempt to assess the potential of CaTiO3 coat