WorldWideScience

Sample records for bipolar pacemaker current

  1. Does bipolar pacemaker current activate blood platelets?

    DEFF Research Database (Denmark)

    Gjesdal, Grunde; Hansen, Annebirthe Bo; Brandes, Axel

    2009-01-01

    to the pacemaker can. METHODS: Platelet-rich plasma was prepared from two healthy subjects. Platelet reactivity to the agonist ADP was tested in paired samples in an aggregometer in a case/control setup. RESULTS: Eighteen of 46 tested pairs of platelet-rich plasma showed increased reactivity in the paced sample......OBJECTIVE: The aim of this study was to investigate whether bipolar pacemaker current lead can activate blood platelets. The null hypothesis was that 1 minute of electrical stimulation of platelets would not influence their subsequent reactivity to adenosine diphosphate (ADP). BACKGROUND: Both...... platelets and muscle cells contain actin and myosin filaments, and both cells are activated following calcium influx. Muscle cells open their calcium channels and contract when exposed to an electric current. Current through a bipolar pacemaker lead will expose a small volume of blood, including platelets...

  2. Pacemaker

    Science.gov (United States)

    ... heart disease or for people who have had heart transplants . Children, teens, and adults can use pacemakers. Before ... also may give you antibiotics to prevent infection. First, your doctor will insert a needle into a ...

  3. Hyperpolarization-activated current, If, in mathematical models of rabbit sinoatrial node pacemaker cells

    NARCIS (Netherlands)

    Verkerk, Arie O.; Wilders, Ronald

    2013-01-01

    A typical feature of sinoatrial (SA) node pacemaker cells is the presence of an ionic current that activates upon hyperpolarization. The role of this hyperpolarization-activated current, If, which is also known as the "funny current" or "pacemaker current," in the spontaneous pacemaker activity of

  4. Electrophysiological Evidence for Intrinsic Pacemaker Currents in Crayfish Parasol Cells.

    Directory of Open Access Journals (Sweden)

    DeForest Mellon

    Full Text Available I used sharp intracellular electrodes to record from parasol cells in the semi-isolated crayfish brain to investigate pacemaker currents. Evidence for the presence of the hyperpolarization-activated inward rectifier potassium current was obtained in about half of the parasol cells examined, where strong, prolonged hyperpolarizing currents generated a slowly-rising voltage sag, and a post-hyperpolarization rebound. The amplitudes of both the sag voltage and the depolarizing rebound were dependent upon the strength of the hyperpolarizing current. The voltage sag showed a definite threshold and was non-inactivating. The voltage sag and rebound depolarization evoked by hyperpolarization were blocked by the presence of 5-10 mM Cs2+ ions, 10 mM tetraethyl ammonium chloride, and 10 mM cobalt chloride in the bathing medium, but not by the drug ZD 7288. Cs+ ions in normal saline in some cells caused a slight increase in mean resting potential and a reduction in spontaneous burst frequency. Many of the neurons expressing the hyperpolarization-activated inward potassium current also provided evidence for the presence of the transient potassium current IA, which was inferred from experimental observations of an increased latency of post-hyperpolarization response to a depolarizing step, compared to the response latency to the depolarization alone. The latency increase was reduced in the presence of 4-aminopyridine (4-AP, a specific blocker of IA. The presence of 4-AP in normal saline also induced spontaneous bursting in parasol cells. It is conjectured that, under normal physiological conditions, these two potassium currents help to regulate burst generation in parasol cells, respectively, by helping to maintain the resting membrane potential near a threshold level for burst generation, and by regulating the rate of rise of membrane depolarizing events leading to burst generation. The presence of post-burst hyperpolarization may depend upon IA channels in

  5. Pacemaker neuron and network oscillations depend on a neuromodulator-regulated linear current

    Directory of Open Access Journals (Sweden)

    Shunbing Zhao

    2010-05-01

    Full Text Available Linear leak currents have been implicated in the regulation of neuronal excitability, generation of neuronal and network oscillations, and network state transitions. Yet, few studies have directly tested the dependence of network oscillations on leak currents or explored the role of leak currents on network activity. In the oscillatory pyloric network of decapod crustaceans neuromodulatory inputs are necessary for pacemaker activity. A large subset of neuromodulators is known to activate a single voltage-gated inward current IMI, which has been shown to regulate the rhythmic activity of the network and its pacemaker neurons. Using the dynamic clamp technique, we show that the crucial component of IMI for the generation of oscillatory activity is only a close-to-linear portion of the current-voltage relationship. The nature of this conductance is such that the presence or the absence of neuromodulators effectively regulates the amount of leak current and the input resistance in the pacemaker neurons. When deprived of neuromodulatory inputs, pyloric oscillations are disrupted; yet, a linear reduction of the total conductance in a single neuron within the pacemaker group recovers not only the pacemaker activity in that neuron, but also leads to a recovery of oscillations in the entire pyloric network. The recovered activity produces proper frequency and phasing that is similar to that induced by neuromodulators. These results show that the passive properties of pacemaker neurons can significantly affect their capacity to generate and regulate the oscillatory activity of an entire network, and that this feature is exploited by neuromodulatory inputs.

  6. Pacemaker Dependency after Cardiac Surgery: A Systematic Review of Current Evidence.

    Science.gov (United States)

    Steyers, Curtis M; Khera, Rohan; Bhave, Prashant

    2015-01-01

    Severe postoperative conduction disturbances requiring permanent pacemaker implantation frequently occur following cardiac surgery. Little is known about the long-term pacing requirements and risk factors for pacemaker dependency in this population. We performed a systematic review of the literature addressing rates and predictors of pacemaker dependency in patients requiring permanent pacemaker implantation after cardiac surgery. Using a comprehensive search of the Medline, Web of Science and EMBASE databases, studies were selected for review based on predetermined inclusion and exclusion criteria. A total of 8 studies addressing the endpoint of pacemaker-dependency were identified, while 3 studies were found that addressed the recovery of atrioventricular (AV) conduction endpoint. There were 10 unique studies with a total of 780 patients. Mean follow-up ranged from 6-72 months. Pacemaker dependency rates ranged from 32%-91% and recovery of AV conduction ranged from 16%-42%. There was significant heterogeneity with respect to the definition of pacemaker dependency. Several patient and procedure-specific variables were found to be independently associated with pacemaker dependency, but these were not consistent between studies. Pacemaker dependency following cardiac surgery occurs with variable frequency. While individual studies have identified various perioperative risk factors for pacemaker dependency and non-resolution of AV conduction disease, results have been inconsistent. Well-conducted studies using a uniform definition of pacemaker dependency might identify patients who will benefit most from early permanent pacemaker implantation after cardiac surgery.

  7. Intracardiac Origin of Heart Rate Variability, Pacemaker Funny Current and their Possible Association with Critical Illness

    Science.gov (United States)

    Papaioannou, Vasilios E; Verkerk, Arie O; Amin, Ahmed S; de Bakker, Jaques MT

    2013-01-01

    Heart rate variability (HRV) is an indirect estimator of autonomic modulation of heart rate and is considered a risk marker in critical illness, particularly in heart failure and severe sepsis. A reduced HRV has been found in critically ill patients and has been associated with neuro-autonomic uncoupling or decreased baroreflex sensitivity. However, results from human and animal experimental studies indicate that intracardiac mechanisms might also be responsible for interbeat fluctuations. These studies have demonstrated that different membrane channel proteins and especially the so-called ‘funny’ current (If), an hyperpolarization-activated, inward current that drives diastolic depolarization resulting in spontaneous activity in cardiac pacemaker cells, are altered during critical illness. Furthermore, membrane channels kinetics seem to have significant impact upon HRV, whose early decrease might reflect a cellular metabolic stress. In this review article we present research findings regarding intracardiac origin of HRV, at the cellular level and in both isolated sinoatrial node and whole ex vivo heart preparations. In addition, we will review results from various experimental studies that support the interrelation between If and HRV during endotoxemia. We suggest that reduced HRV during sepsis could also be associated with altered pacemaker cell membrane properties, due to ionic current remodeling. PMID:22920474

  8. Heart pacemaker - discharge

    Science.gov (United States)

    Cardiac pacemaker implantation - discharge; Artificial pacemaker - discharge; Permanent pacemaker - discharge; Internal pacemaker - discharge; Cardiac resynchronization therapy - discharge; CRT - discharge; ...

  9. Bipolar latch with compensated keep-alive current

    Directory of Open Access Journals (Sweden)

    Dr. Hans Gustat

    2015-03-01

    Full Text Available A permanent current in addition to the main clocked current is sometimes used to increase the maximum clock rate of a bipolar latch. Although it speeds up the activation of a clocked differential stage, it deteriorates the latch function by the additional current in the inactive phase of each differential stage. Thus, a keep-alive current must be kept small with respect to the main clocked current. In this Letter, a compensation technique is shown avoiding the erroneous output of a keep-alive current. It still speeds up the activation of the main transistor pair, but results in a constant symmetric offset without affecting the differential value of the output voltage. In simulations of flip-flops and clocked comparators, this compensated keep-alive current has a much larger effect on the maximum clock rate than the uncompensated keep-alive current used so far.

  10. Current irritability robustly related to current and prior anxiety in bipolar disorder.

    Science.gov (United States)

    Yuen, Laura D; Miller, Shefali; Wang, Po W; Hooshmand, Farnaz; Holtzman, Jessica N; Goffin, Kathryn C; Shah, Saloni; Ketter, Terence A

    2016-08-01

    Although current irritability and current/prior anxiety have been associated in unipolar depression, these relationships are less well understood in bipolar disorder (BD). We investigated relationships between current irritability and current/prior anxiety as well as other current emotions and BD illness characteristics. Outpatients referred to the Stanford Bipolar Disorders Clinic during 2000-2011 were assessed with the Systematic Treatment Enhancement Program for BD (STEP-BD) Affective Disorders Evaluation. Prevalence and clinical correlates of current irritability and current/prior anxiety and other illness characteristics were examined. Among 497 BD outpatients (239 Type I, 258 Type II; 58.1% female; mean ± SD age 35.6 ± 13.1 years), 301 (60.6%) had baseline current irritability. Patients with versus without current irritability had significantly higher rates of current anxiety (77.1% versus 42.9%, p anxiety disorder (73.1% versus 52.6%, p anxiety than to current anhedonia, sadness, or euphoria (all p anxiety associations persisted across current predominant mood states. Current irritability was more robustly related to past anxiety than to all other assessed illness characteristics, including 1° family history of mood disorder, history of alcohol/substance use disorder, bipolar subtype, and current syndromal/subsyndromal depression (all p anxiety. Further studies are warranted to assess longitudinal clinical implications of relationships between irritability and anxiety in BD. Copyright © 2016 Elsevier Ltd. All rights reserved.

  11. Analysis of subthreshold pace-maker currents in chick embryonic heart cells.

    Science.gov (United States)

    Clay, J R; Shrier, A

    1981-03-01

    1. Small re-aggregates of cells dissociated from the ventricles of 7-day-old chick embryonic hearts beat spontaneously in low external potassium concentration (Ko = 1.3 mM) tissue culture medium. This activity was blocked by the addition of tetrodotoxin (TTX) or potassium ions to the external medium. 2. A two-micro-electrode voltage-clamp technique was used to analyse the subthreshold currents responsible for the pace-maker depolarization. 3. Voltage-clamp steps 6-10 sec in duration revealed a time-dependent current having first order kinetics. Its membrane potential range of steady-state activation was -90 to -60 mV. 4. The current kinetics were qualitatively similar to those of Hodgkin & Huxley (1952b) with a peak time constant of approximately 1 sec at V = -75 mV. The kinetics were independent of Ko. 5. The time-dependent current was attributed to gated membrane channels. The fully activated current-voltage (I-V) relation of the channels was determined from the ratio of the amplitudes of the time-dependent currents during and after voltage-clamp steps following the procedure of Noble & Tsien (1968). 6. The fully activated I-V relation displayed inward rectification with negative slope conductance at potentials more than 15 mV positive to its reversal potential. Changes of Ko shifted the I-V curve along the voltage axis like a potassium electrode. 7. The time-independent (background) current was obtained by subtracting the gated channel current from the steady-state I-V curve. This current also rectified in the inward direction. 8. The inwardly rectifying I-V relations were theoretically described by a channel having a row of ion-selective sites along which ions move in a single file (Hodgkin & Keynes, 1955), and a membrane-bound particle which blocked the channel in a voltage-dependent manner. 9. The relationship of the voltage-clamp results to spontaneous activity is discussed and comparisons are made with measurements from whole embryonic heart and other

  12. Pacemaker (image)

    Science.gov (United States)

    A pacemaker is a small, battery-operated electronic device which is inserted under the skin to help the heart beat regularly and at an appropriate rate. The pacemaker has leads that travel through a large vein ...

  13. Intracellular Ca(2+) release from endoplasmic reticulum regulates slow wave currents and pacemaker activity of interstitial cells of Cajal.

    Science.gov (United States)

    Zhu, Mei Hong; Sung, Tae Sik; O'Driscoll, Kate; Koh, Sang Don; Sanders, Kenton M

    2015-04-15

    Interstitial cells of Cajal (ICC) provide pacemaker activity in gastrointestinal muscles that underlies segmental and peristaltic contractions. ICC generate electrical slow waves that are due to large-amplitude inward currents resulting from anoctamin 1 (ANO1) channels, which are Ca(2+)-activated Cl(-) channels. We investigated the hypothesis that the Ca(2+) responsible for the stochastic activation of ANO1 channels during spontaneous transient inward currents (STICs) and synchronized activation of ANO1 channels during slow wave currents comes from intracellular Ca(2+) stores. ICC, obtained from the small intestine of Kit(+/copGFP) mice, were studied under voltage and current clamp to determine the effects of blocking Ca(2+) uptake into stores and release of Ca(2+) via inositol 1,4,5-trisphosphate (IP3)-dependent and ryanodine-sensitive channels. Cyclocpiazonic acid, thapsigargin, 2-APB, and xestospongin C inhibited STICs and slow wave currents. Ryanodine and tetracaine also inhibited STICs and slow wave currents. Store-active compounds had no direct effects on ANO1 channels expressed in human embryonic kidney-293 cells. Under current clamp, store-active drugs caused significant depolarization of ICC and reduced spontaneous transient depolarizations (STDs). After block of ryanodine receptors with ryanodine and tetracaine, repolarization did not restore STDs. ANO1 expressed in ICC has limited access to cytoplasmic Ca(2+) concentration, suggesting that pacemaker activity depends on Ca(2+) dynamics in restricted microdomains. Our data from studies of isolated ICC differ somewhat from studies on intact muscles and suggest that release of Ca(2+) from both IP3 and ryanodine receptors is important in generating pacemaker activity in ICC. Copyright © 2015 the American Physiological Society.

  14. Intracellular Ca2+ release from endoplasmic reticulum regulates slow wave currents and pacemaker activity of interstitial cells of Cajal

    Science.gov (United States)

    Zhu, Mei Hong; Sung, Tae Sik; O'Driscoll, Kate; Koh, Sang Don

    2015-01-01

    Interstitial cells of Cajal (ICC) provide pacemaker activity in gastrointestinal muscles that underlies segmental and peristaltic contractions. ICC generate electrical slow waves that are due to large-amplitude inward currents resulting from anoctamin 1 (ANO1) channels, which are Ca2+-activated Cl− channels. We investigated the hypothesis that the Ca2+ responsible for the stochastic activation of ANO1 channels during spontaneous transient inward currents (STICs) and synchronized activation of ANO1 channels during slow wave currents comes from intracellular Ca2+ stores. ICC, obtained from the small intestine of Kit+/copGFP mice, were studied under voltage and current clamp to determine the effects of blocking Ca2+ uptake into stores and release of Ca2+ via inositol 1,4,5-trisphosphate (IP3)-dependent and ryanodine-sensitive channels. Cyclocpiazonic acid, thapsigargin, 2-APB, and xestospongin C inhibited STICs and slow wave currents. Ryanodine and tetracaine also inhibited STICs and slow wave currents. Store-active compounds had no direct effects on ANO1 channels expressed in human embryonic kidney-293 cells. Under current clamp, store-active drugs caused significant depolarization of ICC and reduced spontaneous transient depolarizations (STDs). After block of ryanodine receptors with ryanodine and tetracaine, repolarization did not restore STDs. ANO1 expressed in ICC has limited access to cytoplasmic Ca2+ concentration, suggesting that pacemaker activity depends on Ca2+ dynamics in restricted microdomains. Our data from studies of isolated ICC differ somewhat from studies on intact muscles and suggest that release of Ca2+ from both IP3 and ryanodine receptors is important in generating pacemaker activity in ICC. PMID:25631870

  15. Cardiac Pacemakers

    International Nuclear Information System (INIS)

    Fiandra, O.; Espasandin, W.; Fiandra, H.

    1984-01-01

    A complete survey of physiological biophysical,clinical and engineering aspects of cardiac facing,including the history and an assessment of possible future developments.Among the topics studied are: pacemakers, energy search, heart stimulating with pacemakers ,mathematical aspects of the electric cardio stimulation chronic, pacemaker implants,proceeding,treatment and control

  16. Correlates of current suicide risk among Thai patients with bipolar I disorder: findings from the Thai Bipolar Disorder Registry

    Directory of Open Access Journals (Sweden)

    Suttajit S

    2013-11-01

    Full Text Available Sirijit Suttajit,1 Suchat Paholpak,2 Somrak Choovanicvong,3 Khanogwan Kittiwattanagul,4 Wetid Pratoomsri,5 Manit Srisurapanont1On behalf of the Thai Bipolar Registry Group1Department of Psychiatry, Chiang Mai University, Chiang Mai, 2Department of Psychiatry, Khon Kaen University, Khon Kaen, 3Srithanya Hospital, Nonthaburi, 4Khon Kaen Rajanagarindra Psychiatric Hospital, Khon Kaen, 5Chachoengsao Hospital, Chachoengsao, ThailandBackground: The Thai Bipolar Disorder Registry was a prospective, multisite, naturalistic study conducted in 24 hospitals across Thailand. This study aimed to examine the correlates of current suicide risk in Thai patients with bipolar I disorder.Methods: Participants were adult inpatients or outpatients with bipolar disorder, based on the Diagnosis and Statistical Manual of Mental Disorders, fourth edition. All were assessed by using the Mini International Neuropsychiatric Interview (MINI, version 5. The severity of current suicide risk was determined by using the total score of the MINI suicidality module. Mood symptoms were assessed by using the Young Mania Rating Scale and the Montgomery Asberg Depression Rating Scale.Results: The data of 383 bipolar I disorder patients were included in the analyses. Of these, 363 (94.8% were outpatients. The mean (standard deviation of the MINI suicide risk score was 1.88 (5.0. The demographic/clinical variables significantly associated with the MINI suicide risk scores included age, number of overall previous episodes, the Young Mania Rating Scale score, the Montgomery Asberg Depression Rating Scale scores, and the Clinical Global Impression Severity of Illness Scale for Bipolar Disorder mania score, depression score, and overall score. The variables affecting the differences of suicide risk scores between or among groups were type of first mood episode, a history of rapid cycling, anxiety disorders, and alcohol use disorders. The stepwise multiple linear regression model revealed

  17. Chronopotentiometry for the advanced current-voltage characterisation of bipolar membranes

    NARCIS (Netherlands)

    Wilhelm, F.G.; van der Vegt, N.F.A.; Wessling, Matthias; Strathmann, H.

    2001-01-01

    Compared to steady-state current¿voltage curves, chronopotentiometric measurements allow us to distinguish the contributions to the overall electric potential difference across a bipolar membrane. In this paper, the characteristic values of the electric potential difference across the bipolar

  18. Behaviour of bipolar membranes at high current density. Water diffusion limitation

    NARCIS (Netherlands)

    Krol, J.J.; Jansink, M.G.J.; Wessling, Matthias; Strathmann, H.

    1998-01-01

    In this paper the behaviour of bipolar membranes at very high current density is discussed. Current–voltage curves are determined, both for the Tokuyama Soda BP-1 and the WSI Technologies bipolar membrane. The current–voltage curves are characterised by an inflection point at which a drastic

  19. Current and Emerging Therapies for the Management of Bipolar Disorders

    Directory of Open Access Journals (Sweden)

    Rif S. El-Mallakh

    2011-01-01

    Full Text Available Bipolar disorder is a complex condition to treat because agents that may be effective for a specific phase may not be effective for other phases, or may even worsen the overall course of the illness. Over the last decade there has been an increase in research activity in the treatment of bipolar illness. There are now several agents that are well established for the treatment of acute mania (lithium, divalproex, carbamazepine, nearly all antipsychotics, acute bipolar depression (lamotrigine, quetiapine, olanzapine/fluoxetine combination, and relapse prevention (lithium, lamotrigine, divalproex, most second generation antipsychotics. There are also novel treatments that are being studied for all three phases. These include eslicarbazepine, cariprazine, MEM-1003, memantine, tamoxifen and pentazocine for acute mania; pramipexole, modafinil, armodafinil, divalproex, lurasidone, agomelatine, cariprazine, lisedexamfetamine, riluzole, RG-2417, bifeprunox, ropinirole, GSK1014802, and magnetic stimulation for bipolar depression; and asenapine, lurasidone, and cariprazine for relapse prevention. Additionally, there are accumulating data that antidepressants, particularly serotoninergic ones, are not particularly effective in acute bipolar depression and may worsen the course of the illness.

  20. Prospective randomized comparative study of bipolar versus direct current electrocoagulation for treatment of bleeding internal hemorrhoids.

    Science.gov (United States)

    Randall, G M; Jensen, D M; Machicado, G A; Hirabayashi, K; Jensen, M E; You, S; Pelayo, E

    1994-01-01

    Internal hemorrhoids are the most common cause of lower gastrointestinal bleeding. Although new anoscopic therapies are available, few comparative randomized studies have evaluated them in regard to long-term efficacy, recurrence rates, and safety. Our purpose was to compare the treatment of internal hemorrhoids with direct current (Ultroid, Cabot Medical, Langhorn, Pa.) and bipolar (BICAP, Circon ACMI, Stamford, Conn.) hemorrhoid probes. One hundred patients with symptomatic internal hemorrhoids were randomized: 50 to direct current electrocoagulation and 50 to bipolar electrocoagulation. Follow-up and treatment were at 3- to 4-weekly intervals; two to three hemorrhoid segments were treated at each session until relief of symptoms (bleeding, prolapse, and discharge) and a reduction in hemorrhoid size to grade 1 or 0 were noted. The hemorrhoids of 98% of all patients studied were grade 2 or 3; 2% of patients had grade 1 hemorrhoids and none had grade 4 hemorrhoids. At 1 year after treatment, most patients had no (69%) or only mild (23%) recurrence, and a few had severe, symptomatic (8%) hemorrhoid recurrence. A greater recurrence rate was noted after direct current treatment (34%) than bipolar treatment (29%). In contrast, rebleeding at 1 year occurred less frequently after direct current treatment (5%) than after bipolar treatment (20%). Our conclusions were as follows: (1) Both direct current and bipolar probes were effective for control of chronic bleeding from grade 1 to 3 internal hemorrhoids. (2) Bipolar probe was significantly faster than direct current probe. (3) Direct current treatment produced fewer complications than bipolar treatment (12% versus 14%). (4) Recurrence rates were low after 1 year with either device (8%).(ABSTRACT TRUNCATED AT 250 WORDS)

  1. Advanced Pacemaker

    Science.gov (United States)

    1990-01-01

    Synchrony, developed by St. Jude Medical's Cardiac Rhythm Management Division (formerly known as Pacesetter Systems, Inc.) is an advanced state-of-the-art implantable pacemaker that closely matches the natural rhythm of the heart. The companion element of the Synchrony Pacemaker System is the Programmer Analyzer APS-II which allows a doctor to reprogram and fine tune the pacemaker to each user's special requirements without surgery. The two-way communications capability that allows the physician to instruct and query the pacemaker is accomplished by bidirectional telemetry. APS-II features 28 pacing functions and thousands of programming combinations to accommodate diverse lifestyles. Microprocessor unit also records and stores pertinent patient data up to a year.

  2. New Concepts in Pacemaker Syndrome

    Directory of Open Access Journals (Sweden)

    D. Michael Farmer

    2004-10-01

    Full Text Available After implantation of a permanent pacemaker, patients may experience severe symptoms of dyspnea, palpitations, malaise, and syncope resulting from pacemaker syndrome. Although pacemaker syndrome is most often ascribed to the loss of atrioventricular (A-V synchrony, more recent data may also implicate left ventricular dysynchrony caused by right ventricular pacing. Previous studies have not shown reductions in mortality or stroke with rate-modulated dual-chamber (DDDR pacing as compared to ventricular-based (VVI pacing. The benefits in A-V sequential pacing with the DDDR mode are likely mitigated by the interventricular (V-V dysynchrony imposed by the high percentage of ventricular pacing commonly seen in the DDDR mode. Programming DDDR pacemakers to encourage intrinsic A-V conduction and reduce right ventricular pacing will likely decrease heart failure and pacemaker syndrome. Studies are currently ongoing to address these questions.

  3. Heart pacemaker

    Science.gov (United States)

    ... labels Implantable cardioverter defibrillator - discharge Low-salt diet Mediterranean diet Surgical wound care - open Images Pacemaker References Epstein AE, DiMarco JP, Ellenbogen KA, et al. 2012 ACCF/AHA/HRS focused update incorporated into the ACCF/AHA/HRS 2008 guidelines for device-based ...

  4. Improved Model for Increased Surface Recombination Current in Irradiated Bipolar Junction Transistors

    Science.gov (United States)

    Barnaby, H. J.; Vermeire, B.; Campola, M. J.

    2015-08-01

    Current gain degradation in irradiated bipolar junction transistors is primarily due to excess base current caused by enhanced carrier recombination in the emitter-base space-charge region (SCR). Radiation-induced traps at the interface between silicon and the bipolar base oxide facilitate the recombination process primarily above the sensitive emitter-base junction. This leads to an increase in surface recombination current in the SCR, which is a non-ideal component of the BJT's base current characteristic under active bias conditions. In this paper, we derive a precise analytical model for surface recombination current that captures bias dependencies typically omitted from traditional models. This improved model is validated by comparisons to these traditional approaches.

  5. Developmental changes in subthreshold pace-maker currents in chick embryonic heart cells.

    Science.gov (United States)

    Clay, J R; Shrier, A

    1981-03-01

    1. Small re-aggregates of cells dissociated from the ventricles of 12-or 17-day-old chick embryonic hearts have beating properties in low potassium tissue culture medium which differ from re-aggregates prepared from 7-day-old hearts; 12-day preparations either beat with a slower rate than comparable-size 7-day preparations or they are quiescent; 17-day preparations usually do not beat. 2. A two-micro-electrode voltage-clamp technique was used to analyse the membrane currents in these preparations in the -120 to -40 mV potential range. 3. A potassium ion membrane current was measured in 12-day and 17-day preparations which was qualitatively similar to the potassium ion current measured in 7-day preparations (Clay & Shrier, 1981). It differed in that its amplitude was diminished in the ratio 1:0.2:0.03 over the 7-, 12- and 17-day sequence. Furthermore, its maximum time constant was 2 sec at both 12 and 17 days, as compared to 1 sec at 7 days, and its membrane potential range of activation was -80 to -70 mV at 12 and 17 days, as compared to -90 to -60 mV at 7 days. 4. The background current also changed with development, becoming less inward over the 7-, 12- and 17-day sequence. The voltage dependence of this change suggested that it was caused by a developmental decrease of the background sodium current. 5. The change in the background component is primarily responsible for the loss of automaticity over the 7-, 12-, and 17-day sequence.

  6. Subclavian Vein Stenosis/Occlusion Following Transvenous Cardiac Pacemaker and Defibrillator Implantation: Incidence, Pathophysiology and Current Management

    Directory of Open Access Journals (Sweden)

    Brian O'Leary

    2015-08-01

    Full Text Available Subclavian vein stenosis is a common, but usually asymptomatic, complication following cardiac device placement. In addition to reviewing the literature on incidence, pathogenesis and management options for this important clinical problem, we describe two cases of symptomatic subclavian vein occlusion following pacemaker/defibrillator placement and successful treatment with venoplasty and stenting.

  7. Current trends in use of implantable cardioverter defibrillators and cardiac resynchronization therapy with a pacemaker or defibrillator in Japanese pediatric patients: results from a nationwide questionnaire survey.

    Science.gov (United States)

    Suzuki, Tsugutoshi; Sumitomo, Naokata; Yoshimoto, Jun; Miyazaki, Aya; Hinokiyama, Kazuhiro; Ushinohama, Hiroya; Yasukochi, Satoshi

    2014-01-01

    In Japan, the use of implantable cardioverter defibrillators (ICDs), cardiac resynchronization therapy with a biventricular pacemaker (CRTP) and CRT with a defibrillator (CRTD) in children has not been studied statistically, and dual-chamber (DDD) pacemakers are still used for pediatric CRT because of current government regulations. Data were obtained from 15 children's and 74 general hospitals through a questionnaire survey regarding the aforementioned therapies performed before 2012 in Japanese children (<16 years old). ICD, CRT with DDD, CRTP and CRTD were used in 64 (42%), 47 (31%), 34 (22%) and 7 (5%), respectively, of all cases reported (n=152). Among all CRTP and CRT-DDD cases (n=81), the use of DDD accounted for 41% in general hospitals vs. 89% in children's hospitals, and CRT-DDD and CRTP were effective in 67 cases (83%). Of 64 ICD cases, appropriate shocks were experienced in 28 cases (44%), and inappropriate shocks in 19 cases (29%). Additionally, data from the Japan Arrhythmia Device Industry Association obtained for overall device usage analysis revealed that CRTP was more commonly used in children than in adults. There is an increasing need for pediatric device therapy, especially CRTP. However, many children's hospitals were still using DDD pacemakers in 2012. Although the demand for device therapy in children may be small, it is indispensable in pediatric cardiology.

  8. The kinetics and temperature dependence of the pace-maker current if in sheep Purkinje fibres.

    Science.gov (United States)

    Hart, G

    1983-04-01

    The kinetic properties of the if channel in shortened sheep Purkinje fibres were investigated using a two-micro-electrode voltage-clamp technique in the presence of Ba2+, Mn2+ and tetrodotoxin (TTX). The time course of the hyperpolarization-activated if currents (DiFrancesco, 1981 b) at potentials within the activation range was found to depend on whether the channel was switching 'on' or 'off'. At potentials positive to the half-activation point if decay was faster than if onset; at potentials negative to the half-activation point if onset was faster than if decay. The time courses of if onset and decay become similar only at potentials close to the centre of the activation range. If a single exponential was fitted to the time course of if switching, the time constant (tau y) was found to vary as a function of potential from approximately 50 msec to several seconds. The tau y - voltage relation is an extremely steep bell-shaped distribution. Reducing external Na+ (range 140-17.5 mM) did not alter the voltage dependence of the if time course. Increasing external K+ (range 5-60 mM) shifted the if time constants and activation curve by similar amounts in a depolarizing direction. The temperature dependence of if was investigated over the range 27.5-41 degrees C. Cooling reversibly slowed the time course of if activation with a Q10 of 3.13 (S.D. +/- 0.85, n = 62). A reversible reduction in the slope of the fully-activated current-voltage relation was observed on cooling, the Q10 being 1.35 (S.D. +/- 0.07), and was usually accompanied by a small depolarizing shift of the half-activation point and the reversal potential Ef. It is concluded that the if time course shows a marked potential dependence and does not obey Hodgkin-Huxley kinetics. Its temperature dependence resembles that of if in the sino-atrial node (DiFrancesco & Ojeda, 1980).

  9. Cognitive and family correlates of current suicidal ideation in children with bipolar disorder.

    Science.gov (United States)

    Weinstein, Sally M; Van Meter, Anna; Katz, Andrea C; Peters, Amy T; West, Amy E

    2015-03-01

    Suicidality among youth with bipolar disorder is an extreme, but largely unaddressed, public health problem. The current study examined the psychosocial characteristics differentiating youth with varying severities of suicidal ideation that may dictate targets for suicide prevention interventions. Participants included 72 youth aged 7-13 (M=9.19, SD=1.61) with DSM-IV-TR bipolar I, II, or NOS and a parent/caregiver. Current suicidal ideation and correlates were assessed at intake, including: demographics and clinical factors (diagnosis, symptom severity, psychiatric comorbidity); child factors (cognitive risk and quality of life); and family factors (parenting stress, family cohesion, and family rigidity). Current ideation was prevalent in this young sample: 41% endorsed any ideation, and 31% endorsed active forms. Depression symptoms, quality of life, hopelessness, self-esteem, and family rigidity differentiated youth with increasing ideation severity. Separate logistic regressions examined all significant child- and family-level factors, controlling for demographic and clinical variables. Greater family rigidity and lower self-esteem remained significant predictors of current planful ideation. Diagnosis, index episode, comorbidity, and mania severity did not differentiate non-ideators from those with current ideation. Limitations include the small sample to examine low base-rate severe ideation, cross-sectional analyses and generalizability of findings beyond the outpatient clinical sample. Findings underscore the importance of assessing and addressing suicidality in preadolescent youth with bipolar disorder, before youth progress to more severe suicidal behaviors. Results also highlight child self-esteem and family rigidity as key treatment targets to reduce suicide risk in pediatric bipolar disorder. Copyright © 2014 Elsevier B.V. All rights reserved.

  10. Bipolar programmable current supply for superconducting nuclear magnetic resonance magnets

    Science.gov (United States)

    Koivuniemi, Jaakko; Luusalo, Reeta; Hakonen, Pertti

    1998-09-01

    In high resolution continuous-wave nuclear magnetic resonance (NMR) work well-reproducible, linear sweeps of current are needed. We have developed a microcontroller based programmable current supply, tested with superconducting magnets with inductance of 10 mH and 10 H. We achieved a resolution and noise of 4 ppm. The supply has an internal sweep with programmable ramping rate and a possibility for remote operation from a computer with either GPIB or RS232 interface. It is based on an 18-bit D/A converter. The maximum output current is ±10 A, the sweep rate can be set between 1 μA/s-140 mA/s, and the maximum output voltage is ±2.5 V. In work at ultralow temperatures, especially in superconducting quantum interference device NMR, all rf interference to the experiment should be avoided. One of the sources of this kind of unwanted input is the digital switching noise of fast logic devices. We discuss this problem in the context of our design.

  11. Bipolar Junction Transistors in Two-Dimensional WSe2 with Large Current and Photocurrent Gains.

    Science.gov (United States)

    Agnihotri, Pratik; Dhakras, Prathamesh; Lee, Ji Ung

    2016-07-13

    In the development of semiconductor devices, the bipolar junction transistor (BJT) features prominently as being the first solid state transistor that helped to usher in the digital revolution. For any new semiconductor, therefore, the fabrication and characterization of the BJT are important for both technological importance and historical significance. Here, we demonstrate a BJT device in exfoliated TMD semiconductor WSe2. We use buried gates to electrostatically create doped regions with back-to-back p-n junctions. We demonstrate two central characteristics of a bipolar device: current gain when operated as a BJT and a photocurrent gain when operated as a phototransistor. We demonstrate a current gain of 1000 and photocurrent gain of 40 and describe features that enhance these properties due to the doping technique that we employ.

  12. Cardiac pacemaker

    International Nuclear Information System (INIS)

    Kolenik, S.A.

    1976-01-01

    The construction of a cardiac pacemaker is described which is characterized by particularly small dimensions, small weight and long life duration. The weight is under 100g, the specific weight under 1.7. Mass inertia forces which occur through acceleration and retardation processes, thus remain below the threshold values, above which one would have to reckon with considerable damaging of the surrounding body tissue. The maintaining of small size and slight weight is achieved by using an oscillator on COSMOS basis, where by considerably lower energy consumption, amongst others the lifetimes of the batteries used - a lithium anode with thionyl chloride electrolyte - is extended to over 5 years. The reliability can be increased by the use of 2 or more batteries. The designed dimension are 20x60x60 mm 3 . (ORU/LH) [de

  13. CONDENSED MATTER: ELECTRONIC STRUCTURE, ELECTRICAL, MAGNETIC, AND OPTICAL PROPERTIES: Thermal analytic model of current gain for bipolar junction transistor-bipolar static induction transistor compound device

    Science.gov (United States)

    Zhang, You-Run; Zhang, Bo; Li, Ze-Hong; Lai, Chang-Jin; Li, Zhao-Ji

    2009-02-01

    This paper proposes a thermal analytical model of current gain for bipolar junction transistor-bipolar static induction transistor (BJT-BSIT) compound device in the low current operation. It also proposes a best thermal compensating factor to the compound device that indicates the relationship between the thermal variation rate of current gain and device structure. This is important for the design of compound device to be optimized. Finally, the analytical model is found to be in good agreement with numerical simulation and experimental results. The test results demonstrate that thermal variation rate of current gain is below 10% in 25 °C-85°C and 20% in -55°C-25°C.

  14. Tunneling, Current Gain, and Transconductance in Silicon-Germanium Heterojunction Bipolar Transistors Operating at Millikelvin Temperatures

    Science.gov (United States)

    Davidović, D.; Ying, H.; Dark, J.; Wier, B. R.; Ge, L.; Lourenco, N. E.; Omprakash, A. P.; Mourigal, M.; Cressler, J. D.

    2017-08-01

    Quantum-transport measurements in advanced silicon-germanium heterojunction bipolar transistors (SiGe HBTs) are presented and analyzed, including tunneling spectroscopy of discrete impurity levels localized within the transistor and the dependence on an applied magnetic field. The collector current at millikelvin temperatures is well accounted for by ideal electron tunneling throughout the entire base. The amplification principle at millikelvin temperatures is fundamentally quantum mechanical in nature: an increase in base voltage, requiring a moderate base current, creates an equal and opposite decrease in the tunneling barrier seen by the electrons in the emitter, thereby increasing the collector current significantly more than the base current, producing current gain. Highly scaled SiGe HBTs operate predictably at millikelvin temperatures, thus opening the possibility of viable SiGe millikelvin circuitry.

  15. Physical processes of current gain in InAs bipolar junction transistors

    Science.gov (United States)

    Wu, X.; Averett, K. L.; Maimon, S.; Koch, M. W.; Wicks, G. W.

    2004-01-01

    InAs bipolar junction transistors (BJTs), grown by molecular beam epitaxy, are reported with common emitter current gains ( β's) as large as 400. The factors affecting the common emitter current gain have been studied by estimating the magnitudes of the base transport factor ( αT) and emitter injection efficiency ( γ). This has been accomplished by studying a sequence of InAs BJTs with varying emitter doping densities, NE. Minority carrier diffusion length in the base ( LB), αT, and γ have been extracted from measured electrical characteristics. The results of the study of these InAs BJTs are as follows: L B≈0.4 μm, αT≈98% and γ ranges from 92% to nearly 100% depending on NE. This knowledge of the magnitudes of the injection efficiencies suggests when it would be useful to move from the simple BJT structure to the more advanced heterojunction bipolar transistor (HBT) structure. Lower γ BJTs would be improved, however high- γ BJTs would benefit little, by the use of the widegap emitters of HBTs. The method developed here to estimate γ, αT and LB is not specific to InAs BJTs, but should be useful for study of BJTs and HBTs in any material system.

  16. Effect of the interface recombination current fluctuations on 1/f noise of gated lateral bipolar transistors

    Science.gov (United States)

    Romas, Gregory G., Jr.; Ul Hoque, Md Mazhar; Celik-Butler, Zeynep

    2003-05-01

    A gated lateral bipolar transistor is a bulk lateral BJT in parallel with a MOSFET at the surface. The base current components such as surface recombination and space charge recombination currents are two of the dominant noise sources in the lateral BJT. If the gate is biased such that the MOSFET is in the off-state by accumulating carriers underneath the oxide in the base surface, the noise contribution by these two base current (Ib) components can be better understood. The carrier accumulation in the base surface can be modulated with different gate bias, which in turn will affect the fluctuation of the surface recombination current component. In this paper, noise power spectral density of gated lateral PNP transistors, fabricated in Texas Instruments Standard Bipolar Process, has been discussed. The base current noise power spectral density (SIb) was extracted from the cross-correlation noise spectrum measured between the base and the collector circuits for different gate biasing conditions. Based on the frequency exponent dependence of the noise power spectral density, it was found that the noise in the low frequency range is in the form of 1/f noise. SIb was found to be the dominant noise source for these devices as the coherence between the base and collector power spectral density was very close to 1. SIb was extracted for a base current range of 8 nA to 1microA for a gate bias range of 0V to 40V. The SPICE noise model parameters, AF and KF were also determined for each case from the dependence of SIb on Ib. The noise was measured on devices with different base width values.

  17. Tunneling Current of Electron in Armchair Graphene Nanoribbon Bipolar Transistor Model Using Transfer Matrix Method

    Science.gov (United States)

    Fahmi, A. K.; Hasanah, L.; Rusdiana, D.; Aminudin, A.; Suhendi, E.

    2017-03-01

    The tunneling current of n-p-n bipolar junction transistor AGNR-based is modeled with semi-numerical method. The exponential solution from Schrödinger equation is used and solved analytically. The potential profile of n-p-n BJT divided into several segments in the numerical method. Then, the solved analytical result is used in the numerical method to compute the electron transmittance. Transfer Matrix Method (TMM) is the numerical method used to compute the electron transmittance. From the calculated transmittance the tunneling current can be computed by using Landauer formula with aid of Gauss-Legendre Quadrature (GLQ). Next, the tunneling current is computed with several change of variables which are base-emitter voltage (VBE), base-collector voltage (VBC), temperature and the AGNR’s width. The computed tunneling current shows that the larger value of applied voltage for both VBE and VBC results in larger value of tunneling current. At the lower temperature, the current is larger. The computed tunneling current shows that at wider width of AGNR, the current is also larger. This is due to the decreased band-gap energy (Eg) because of the wider width of AGNR.

  18. The influence of current mood state, number of previous affective episodes and predominant polarity on insight in bipolar disorder.

    Science.gov (United States)

    de Assis da Silva, Rafael; Mograbi, Daniel C; Camelo, Evelyn Vieira Miranda; Peixoto, Ursula; Santana, Cristina Maria Teixeira; Landeira-Fernandez, Jesus; Morris, Robin G; Cheniaux, Elie

    2017-11-01

    Although many studies have explored the effect of current affective episodes on insight into bipolar disorder, the potential interaction between current mood state and previous affective episodes has not been consistently investigated. To explore the influence of dominant polarity, number of previous affective episodes and current affective state on insight in bipolar disorder patients in euthymia or mania. A total of 101 patients with bipolar disorder were recruited for the study, including 58 patients in euthymia (30 with no defined predominant polarity and 28 with manic predominant polarity) and 43 in mania (26 with no defined predominant polarity and 17 with manic predominant polarity). Patients underwent a clinical assessment and insight was evaluated through the Insight Scale for Affective Disorders. Bipolar disorder patients in mania had worse insight than those in euthymia, with no effect of dominant polarity. In addition, positive psychotic symptoms showed a significant effect on insight and its inclusion as a covariate eliminated differences related to mood state. Finally, the number of previous manic or depressive episodes did not correlate with insight level. Mania is a predictor of loss of insight into bipolar disorder. However, it is possible that its contribution is linked to the more frequent presence of psychotic symptoms in this state. Dominant polarity and number/type of previous affective episodes have a limited impact on insight.

  19. Leadless Pacemakers: State of the Art and Future Perspectives.

    Science.gov (United States)

    Della Rocca, Domenico G; Gianni, Carola; Di Biase, Luigi; Natale, Andrea; Al-Ahmad, Amin

    2018-03-01

    Leadless pacemaker therapy is a new technology that aims at avoiding lead- and pocket-related complications of conventional transvenous and epicardial pacing. To date, 2 self-contained leadless pacemakers for right ventricular pacing have been clinically available: the Nanostim Leadless Pacemaker System and the Micra Transcatheter Pacing System. Additionally, a new multicomponent leadless pacemaker for endocardial left ventricular pacing has been proposed as an alternative choice for cardiac resynchronization therapy. In this review, we describe the state of the art of leadless pacing and compare the currently available devices with traditional transvenous leadless pacemakers. Copyright © 2017 Elsevier Inc. All rights reserved.

  20. Lifetime anxiety disorder and current anxiety symptoms associated with hastened depressive recurrence in bipolar disorder.

    Science.gov (United States)

    Shah, Saloni; Kim, Jane P; Park, Dong Yeon; Kim, Hyun; Yuen, Laura D; Do, Dennis; Dell'Osso, Bernardo; Hooshmand, Farnaz; Miller, Shefali; Wang, Po W; Ketter, Terence A

    2017-09-01

    To assess differential relationships between lifetime anxiety disorder/current anxiety symptoms and longitudinal depressive severity in bipolar disorder (BD). Stanford BD Clinic outpatients enrolled during 2000-2011 were assessed with the Systematic Treatment Enhancement Program for BD (STEP-BD) Affective Disorders Evaluation and followed with the STEP-BD Clinical Monitoring Form while receiving naturalistic treatment for up to two years. Baseline unfavorable illness characteristics/current mood symptoms and times to depressive recurrence/recovery were compared in patients with versus without lifetime anxiety disorder/current anxiety symptoms. Among 105 currently recovered patients, lifetime anxiety disorder was significantly associated with 10/27 (37.0%) demographic/other unfavorable illness characteristics/current mood symptoms/current psychotropics, hastened depressive recurrence (driven by earlier onset age), and a significantly (> two-fold) higher Kaplan-Meier estimated depressive recurrence rate, whereas current anxiety symptoms were significantly associated with 10/27 (37.0%) demographic/other unfavorable illness characteristics/current mood symptoms/current psychotropics and hastened depressive recurrence (driven by lifetime anxiety disorder), but only a numerically higher Kaplan-Meier estimated depressive recurrence rate. In contrast, among 153 currently depressed patients, lifetime anxiety disorder/current anxiety symptoms were not significantly associated with time to depressive recovery or depressive recovery rate. American tertiary BD clinic referral sample, open naturalistic treatment. Research is needed regarding differential relationships between lifetime anxiety disorder and current anxiety symptoms and hastened/delayed depressive recurrence/recovery - specifically whether lifetime anxiety disorder versus current anxiety symptoms has marginally more robust association with hastened depressive recurrence, and whether both have marginally more robust

  1. Bipolar square-wave current source for transient electromagnetic systems based on constant shutdown time.

    Science.gov (United States)

    Wang, Shilong; Yin, Changchun; Lin, Jun; Yang, Yu; Hu, Xueyan

    2016-03-01

    Cooperative work of multiple magnetic transmitting sources is a new trend in the development of transient electromagnetic system. The key is the bipolar current waves shutdown, concurrently in the inductive load. In the past, it was difficult to use the constant clamping voltage technique to realize the synchronized shutdown of currents with different peak values. Based on clamping voltage technique, we introduce a new controlling method with constant shutdown time. We use the rising time to control shutdown time and use low voltage power source to control peak current. From the viewpoint of the circuit energy loss, by taking the high-voltage capacitor bypass resistance and the capacitor of the passive snubber circuit into account, we establish the relationship between the rising time and the shutdown time. Since the switch is not ideal, we propose a new method to test the shutdown time by the low voltage, the high voltage and the peak current. Experimental results show that adjustment of the current rising time can precisely control the value of the clamp voltage. When the rising time is fixed, the shutdown time is unchanged. The error for shutdown time deduced from the energy consumption is less than 6%. The new controlling method on current shutdown proposed in this paper can be used in the cooperative work of borehole and ground transmitting system.

  2. Measurements of monopolar and bipolar current spreads using forward-masking with a fixed probe.

    Science.gov (United States)

    Bingabr, Mohamed G; Espinoza-Varas, Blas; Sigdel, Saroj

    2014-05-01

    This research employed a forward-masking paradigm to estimate the current spread of monopolar (MP) and bipolar (BP) maskers, with current amplitudes adjusted to elicit the same loudness. Since the spatial separation between active and return electrodes is smaller in BP than in MP configurations, the BP current spread is more localized and presumably superior in terms of speech intelligibility. Because matching the loudness requires higher current in BP than in MP stimulation, previous forward-masking studies show that BP current spread is not consistently narrower across subjects or electrodes within a subject. The present forward-masking measures of current spread differ from those of previous studies by using the same BP probe electrode configuration for both MP and BP masker configurations, and adjusting the current levels of the MP and BP maskers so as to match them in loudness. With this method, the estimate of masker current spread would not be contaminated by differences in probe current spread. Forward masking was studied in four cochlear implant patients, two females and two males, with speech recognition scores higher than 50%; that is, their auditory-nerve survival status was more than adequate to carry out the experiments. The data showed that MP and BP masker configurations produce equivalent masking patterns (and current spreads) in three participants. A fourth participant displayed asymmetrical patterns with enhancement rather than masking in some cases, especially when the probe and masker were at the same location. This study showed equivalent masking patterns for MP and BP maskers when the BP masker current amplitude was increased to match the loudness of the MP masker, and the same BP probe configuration is used with both maskers. This finding could help to explain why cochlear implant users often fail to accrue higher speech intelligibility benefit from BP stimulation.

  3. Characterization and correction of eddy-current artifacts in unipolar and bipolar diffusion sequences using magnetic field monitoring

    Science.gov (United States)

    Chan, Rachel W.; von Deuster, Constantin; Giese, Daniel; Stoeck, Christian T.; Harmer, Jack; Aitken, Andrew P.; Atkinson, David; Kozerke, Sebastian

    2014-07-01

    Diffusion tensor imaging (DTI) of moving organs is gaining increasing attention but robust performance requires sequence modifications and dedicated correction methods to account for system imperfections. In this study, eddy currents in the "unipolar" Stejskal-Tanner and the velocity-compensated "bipolar" spin-echo diffusion sequences were investigated and corrected for using a magnetic field monitoring approach in combination with higher-order image reconstruction. From the field-camera measurements, increased levels of second-order eddy currents were quantified in the unipolar sequence relative to the bipolar diffusion sequence while zeroth and linear orders were found to be similar between both sequences. Second-order image reconstruction based on field-monitoring data resulted in reduced spatial misalignment artifacts and residual displacements of less than 0.43 mm and 0.29 mm (in the unipolar and bipolar sequences, respectively) after second-order eddy-current correction. Results demonstrate the need for second-order correction in unipolar encoding schemes but also show that bipolar sequences benefit from second-order reconstruction to correct for incomplete intrinsic cancellation of eddy-currents.

  4. Compliance current dependence of conversion between bipolar, unipolar, and threshold resistance switching in Mn3O4 films

    Directory of Open Access Journals (Sweden)

    Shuxiang Wu

    2015-08-01

    Full Text Available We report deterministic conversion between bipolar, unipolar and threshold resistance switching in Pt/Mn3O4/Pt memory devices via tuning compliance current. The conversion between bipolar and unipolar switching is reversible, while that between memory switching and threshold switching is irreversible. The nonvolatile bipolar resistance switching behaviors could be attributed to modification of Schottky barrier at Pt/Mn3O4 interface due to the migration of positively charged oxygen vacancies. With the increase of current, the incomplete filament formed in the set operation of bipolar switching could continue to grow and until completely form. The subsequent rupture and formation of filament consisting of oxygen vacancies under electric field are responsible for the unipolar resistance switching. Further increase of compliance current causes the volatile threshold switching behavior in the Pt/Mn3O4/Pt devices, which could be originated from formation and rupture of filament consisting of Mn ions due to the high Joule heat generated by large current.

  5. Permanent Leadless Cardiac Pacemaker Therapy: A Comprehensive Review.

    Science.gov (United States)

    Tjong, Fleur V Y; Reddy, Vivek Y

    2017-04-11

    A new technology, leadless pacemaker therapy, was recently introduced clinically to address lead- and pocket-related complications in conventional transvenous pacemaker therapy. These leadless devices are self-contained right ventricular single-chamber pacemakers implanted by using a femoral percutaneous approach. In this review of available clinical data on leadless pacemakers, early results with leadless devices are compared with historical results with conventional single-chamber pacing. Both presently manufactured leadless pacemakers show similar complications, which are mostly related to the implant procedure: cardiac perforation, device dislocation, and femoral vascular access site complications. In comparison with conventional transvenous single-chamber pacemakers, slightly higher short-term complication rates have been observed: 4.8% for leadless pacemakers versus 4.1% for conventional pacemakers. The complication rate of the leadless pacemakers is influenced by the implanter learning curve for this new procedure. No long-term outcome data are yet available for the leadless pacemakers. Larger leadless pacing trials, with long-term follow-up and direct randomized comparison with conventional pacing systems, will be required to define the proper clinical role of these leadless systems. Although current leadless pacemakers are limited to right ventricular pacing, future advanced, communicating, multicomponent systems are expected to expand the potential benefits of leadless therapy to a larger patient population. © 2017 American Heart Association, Inc.

  6. Mathematical Models of Cardiac Pacemaking Function

    Directory of Open Access Journals (Sweden)

    Pan eLi

    2013-10-01

    Full Text Available Over the past half century, there has been intense and fruitful interaction between experimental and computational investigations of cardiac function. This interaction has, for example, led to deep understanding of cardiac excitation-contraction coupling; how it works, as well as how it fails. However, many lines of inquiry remain unresolved, among them the initiation of each heartbeat. The sinoatrial node, a cluster of specialized pacemaking cells in the right atrium of the heart, spontaneously generates an electro-chemical wave that spreads through the atria and through the cardiac conduction system to the ventricles, initiating the contraction of cardiac muscle essential for pumping blood to the body. Despite the fundamental importance of this primary pacemaker, this process is still not fully understood, and ionic mechanisms underlying cardiac pacemaking function are currently under heated debate. Several mathematical models of sinoatrial node cell membrane electrophysiology have been constructed as based on different experimental data sets and hypotheses. As could be expected, these differing models offer diverse predictions about cardiac pacemaking activities. This paper aims to present the current state of debate over the origins of the pacemaking function of the sinoatrial node. Here, we will specifically review the state-of-the-art of cardiac pacemaker modeling, with a special emphasis on current discrepancies, limitations, and future challenges.

  7. What Is a Pacemaker?

    Science.gov (United States)

    ... your pacemaker. • If you work around industrial microwaves, electricity, cars or other large motors, ask your doctor about possible effects. Can I use a cell phone or microwave oven if I have a pacemaker? Microwave ovens, electric blankets, remote controls for TV and other common ...

  8. Mixed states in bipolar disorder - changes in DSM-5 and current treatment recommendations.

    Science.gov (United States)

    Betzler, Felix; Stöver, Laura Apollonia; Sterzer, Philipp; Köhler, Stephan

    2017-11-01

    Mixed states in affective disorders represent a particular challenge in clinical routine, characterized by a complicated course of treatment and a worse treatment response. Clinical features of mixed states and the Diagnostic and Statistical Manual of Mental Disorders (DSM-5) criteria are presented and critical discussed. We then performed a systematic review using the terms 'bipolar', 'mixed' and 'randomized' to evaluate current treatment options. For pharmacological treatment of mixed states in total, there is still insufficient data from RCTs. However, there is some evidence for efficacy in mixed states from RCTs for atypical antipsychotics, especially olanzapine, aripiprazole and asenapine as well as mood stabilizers as valproate and carbamazepine. Mixed states are of a high clinical relevance and the DSM-5 criteria substantially reduced the diagnostic threshold. Besides advantages of a better characterization of patients with former DSM-IV-defined mixed episodes, disadvantages arise for example differential diagnoses with a substantial overlap in symptoms such as borderline personality disorders. Atypical antipsychotics, valproate and carbamazepine demonstrated efficacy in a limited sample of RCTs. The number of RCTs in the treatment of mixed states is highly limited. Furthermore, nearly all studies were funded by pharmaceutical companies which may lead to an underestimation of classical mood stabilizers such as lithium.

  9. Empirically supported psychosocial interventions for bipolar disorder: Current state of the research.

    Science.gov (United States)

    Salcedo, Stephanie; Gold, Alexandra K; Sheikh, Sana; Marcus, Peter H; Nierenberg, Andrew A; Deckersbach, Thilo; Sylvia, Louisa G

    2016-09-01

    Bipolar disorder requires psychiatric medications, but even guideline-concordant treatment fails to bring many patients to remission or keep them euthymic. To address this gap, researchers have developed adjunctive psychotherapies. The purpose of this paper is to critically review the evidence for the efficacy of manualized psychosocial interventions for bipolar disorder. We conducted a search of the literature to examine recent (2007-present), randomized controlled studies of the following psychotherapy interventions for bipolar disorder: psychoeducation (PE), cognitive behavioral therapy (CBT), interpersonal and social rhythm therapy (IPSRT), dialectical behavior therapy (DBT), mindfulness-based cognitive therapy (MBCT), and family therapies such as family focused therapy (FFT). All of the psychotherapy interventions appear to be effective in reducing depressive symptoms. Psychoeducation and CBT are associated with increased time to mood episode relapse or recurrence. MBCT has demonstrated a particular effectiveness in improving depressive and anxiety symptoms. Online psychotherapy interventions, programs combining one or more psychotherapy interventions, and targeted interventions centering on particular symptoms have been the focus of recent, randomized controlled studies in bipolar disorder. Psychotherapy interventions for the treatment of bipolar disorder have substantial evidence for efficacy. The next challenge will to disseminate these psychotherapies into the community. Copyright © 2016 Elsevier B.V. All rights reserved.

  10. [Analysis of pacemaker ECGs].

    Science.gov (United States)

    Israel, Carsten W; Ekosso-Ejangue, Lucy; Sheta, Mohamed-Karim

    2015-09-01

    The key to a successful analysis of a pacemaker electrocardiogram (ECG) is the application of the systematic approach used for any other ECG without a pacemaker: analysis of (1) basic rhythm and rate, (2) QRS axis, (3) PQ, QRS and QT intervals, (4) morphology of P waves, QRS, ST segments and T(U) waves and (5) the presence of arrhythmias. If only the most obvious abnormality of a pacemaker ECG is considered, wrong conclusions can easily be drawn. If a systematic approach is skipped it may be overlooked that e.g. atrial pacing is ineffective, the left ventricle is paced instead of the right ventricle, pacing competes with intrinsic conduction or that the atrioventricular (AV) conduction time is programmed too long. Apart from this analysis, a pacemaker ECG which is not clear should be checked for the presence of arrhythmias (e.g. atrial fibrillation, atrial flutter, junctional escape rhythm and endless loop tachycardia), pacemaker malfunction (e.g. atrial or ventricular undersensing or oversensing, atrial or ventricular loss of capture) and activity of specific pacing algorithms, such as automatic mode switching, rate adaptation, AV delay modifying algorithms, reaction to premature ventricular contractions (PVC), safety window pacing, hysteresis and noise mode. A systematic analysis of the pacemaker ECG almost always allows a probable diagnosis of arrhythmias and malfunctions to be made, which can be confirmed by pacemaker control and can often be corrected at the touch of the right button to the patient's benefit.

  11. Do current national and international guidelines have specific recommendations for older adults with bipolar disorder?

    DEFF Research Database (Denmark)

    Dols, Annemiek; Kessing, Lars Vedel; Strejilevich, Sergio A

    2016-01-01

    a variety of sources have become available in recent years. It is expected that at least some of this emerging information on OABD would be incorporated into treatment guidelines available to clinicians around the world. METHODS: The International Society of Bipolar Disorders OABD task force compiled......OBJECTIVE: Older adults with bipolar disorder (OABD) are a growing segment of patients with bipolar disorder (BD) for which specific guidelines are warranted. Although, OABD are frequently excluded from randomized controlled trials due to their age or somatic comorbidity, more treatment data from...... mental health workforce with geriatric expertise, it is critical that additional effort and resources be devoted to studying treatment interventions specific to OABD and that treatment guidelines reflect research findings. Copyright © 2016 John Wiley & Sons, Ltd....

  12. Cytokines in bipolar disorder

    DEFF Research Database (Denmark)

    Munkholm, Klaus; Vinberg, Maj; Vedel Kessing, Lars

    2012-01-01

    to affective state. METHODS: We conducted a systemtic review of studies measuring endogenous cytokine concentrations in patients with bipolar disorder and a meta-analysis, reporting results according to the PRISMA statement. RESULTS: Thirteen studies were included, comprising 556 bipolar disorder patients......BACKGROUND: Current research and hypothesis regarding the pathophysiology of bipolar disorder suggests the involvement of immune system dysfunction that is possibly related to disease activity. Our objective was to systematically review evidence of cytokine alterations in bipolar disorder according...

  13. The clinical trajectory of emerging bipolar disorder among the high-risk offspring of bipolar parents: current understanding and future considerations.

    Science.gov (United States)

    Duffy, A; Vandeleur, C; Heffer, N; Preisig, M

    2017-11-22

    Relatively little is known about the onset of bipolar disorder, yet the early illness course is already associated with significant morbidity and mortality. Therefore, characterizing the bipolar illness trajectory is key to risk prediction and early intervention advancement. In this narrative review, we discuss key findings from prospective longitudinal studies of the high-risk offspring of bipolar parents and related meta-analyses that inform us about the clinical trajectory of emerging bipolar disorder. Challenges such as phenotypic and etiologic heterogeneity and the non-specificity of early symptoms and syndromes are highlighted. Implications of the findings for both research and clinical practice are discussed. Bipolar disorder in young people at familial risk does not typically onset with a hypomanic or manic episode. Rather the first activated episode is often preceded by years of impairing psychopathological states that vary over development and across emerging bipolar subtype. Taking heterogeneity into account and adopting a more comprehensive approach to diagnosis seems necessary to advance earlier identification and our understanding of the onset of bipolar disorder.

  14. Final generic environmental statement on the routine use of plutonium-powered cardiac pacemakers. Update of information on power sources for pacemakers

    International Nuclear Information System (INIS)

    1979-05-01

    The Final Environmental Statement on Routine Use of Plutonium-Powered Cardiac Pacemakers (FES) was issued in July 1976. Supplement 1, prepared in 1978, updates the FES with respect to power sources for pacemakers. Particular attention is given to the non-nuclear lithium batteries as alternatives to 238-Pu power sources in pacemakers. Supplement 1 also considers the current extent of pacemaker use and makeup of the patient population and concludes that the FES' conclusion is still valid that distribution of 238-Pu powered pacemakers for routine use should be authorized subject to specific conditions

  15. Attentional biases for emotional facial stimuli in currently depressed patients with bipolar disorder

    Directory of Open Access Journals (Sweden)

    Lemke Leyman

    2009-01-01

    Full Text Available En comparación con las numerosas investigaciones centradas en los factores de vulnerabilidad cognitiva que subyacen en el inicio y el desarrollo del trastorno depresivo mayor, los estudios que investigan el procesamiento disfuncional de la información emocional en el trastorno bipolar siguen siendo escasos. Por ello, el presente estudio experimental ha analizado la naturaleza y el curso temporal de los sesgos atencionales en pacientes depresivos con trastorno bipolar. Un total de catorce pacientes deprimidos con Trastorno Bipolar I (TB y catorce participantes controles no deprimidos (CN, emparejados en edad, sexo y nivel educativo, realizaron una modificación emocional de la tarea de señalización espacial. Las señales consistían en expresiones faciales de enfado, neutrales y positivas presentadas durante 200 y 1.000 ms. Los pacientes con TB mostraron un mayor efecto de validación de las señales en las caras de enfado y presentaron más dificultades a la hora de desvincular la atención de las expresiones faciales de enfado y de alegría en comparación con los participantes CN, que por el contrario, demostraron un «sesgo protector» distanciado de la información negativa. Este patrón diferenciado de procesamiento atencional solo se halló en la fase inicial del procesamiento de la información en una presentación de 200 ms de duración. Estos resultados demuestran la existencia de déficits en las fases iniciales del procesamiento atencional de la información emocional en pacientes deprimidos bipolares en comparación con los controles sanos.

  16. Effect of parasitic series resistances and spurious currents on the extracted temperature of a bipolar junction transistor.

    Science.gov (United States)

    Mimila-Arroyo, J

    2013-12-01

    Verster's proposition to directly extract the temperature of a bipolar junction transistor using its collector current is widely used. However, the resulting temperature is low accurate even when calibrated. Here, it is demonstrated that the misuse of the emitter current instead of the collector one, because of the presence of spurious currents other than the injection-diffusion one and transistor parasitic series resistances both contribute to the observed inaccuracy. Particularly parasitic series resistances increase the inaccuracy and introduce a strong dependence of the extracted temperature on the collector currents used to extract the temperature; the higher those resistances the higher the inaccuracy. A proposition is made to reduce the effect of those resistances on the inaccuracy of this thermometric element, which allows obtaining a more accurate value on a wider range of the collector probe currents.

  17. Evolução do conceito e controvérsias atuais sobre o transtorno bipolar do humor Bipolar disorder: evolution of the concept and current controversies

    Directory of Open Access Journals (Sweden)

    José Alberto Del Porto

    2004-10-01

    Full Text Available O autor revê o conceito de transtorno bipolar como um processo em evolução. Suas raízes podem ser encontradas no trabalho de Araeteus da Capadócia, que assumia serem a melancolia e a mania duas formas da mesma doença. A compreensão atual da doença bipolar começou na França, através dos trabalhos de Falret (1851 e Baillarguer (1854. Os conceitos fundamentais de Kraepelin mudaram as bases da nosologia psiquiátrica, e o conceito unitário de Kraepelin sobre a insanidade maníaco-depressiva passou a ser amplamente aceito. Depois de Kraepelin, no entanto, as idéias de Kleist e Leonhard, na Alemanha, e o trabalho subseqüente de Angst, Perris e Winokur enfatizaram a distinção entre as formas monopolares e bipolares da depressão. Mais recentemente a ênfase mudou novamente para o espectro bipolar, que em suas formas leves expande-se às bordas dos temperamentos normais. Finalizando, o autor sumariza os aspectos polêmicos da nosologia da doença bipolar e seus limites com as esquizofrenias, a doença esquizoafetiva e as psicoses ciclóides.The author reviews the evolution of the concept of bipolar disorder as an ongoing process. Its roots can be found in the work of Araeteus of Capadocia, who assumed that melancholia and mania were two forms of the same disease. The modern understanding of bipolar disorder began in France, through the work of Falret (1851 and Baillarger (1854. The pivotal concepts of Emil Kraepelin changed the basis of psychiatric nosology, and Kraepelin's unitary concept of manic-depressive insanity was largely accepted. Kraepelin and Weigandt's ideas on mixed states were the cornerstone of this unitary concept. After Kraepelin, however, the ideas of Kleist and Leonhard, in Germany, as well as the work of Angst, Perris and Winokur, emphasized the distinction between unipolar and bipolar forms of depression. More recently, the emphasis has shifted again to the bipolar spectrum, which, in its mild forms, expanded to the

  18. Waiting for a pacemaker

    DEFF Research Database (Denmark)

    Risgaard, B.; Elming, H.; Jensen, G.V.

    2012-01-01

    AimsTo determine waiting period-related morbidity, mortality, and adverse events in acute patients waiting for a permanent pacemaker (PPM).Methods and resultsA retrospective chart review of all PPM implantations in Region Zealand, Denmark, in 2009 was conducted. Patients were excluded if they were...... event during the waiting period. The present study indicates that a waiting period is dangerous as it is associated with an increased risk of adverse events. Acute PPMs should be implanted with a 24-h pacemaker implantation service capacity. Published on behalf of the European Society of Cardiology. All...

  19. Improving Treatment Adherence in Bipolar Disorder: A Review of Current Psychosocial Treatment Efficacy and Recommendations for Future Treatment Development

    Science.gov (United States)

    Gaudiano, Brandon A.; Weinstock, Lauren M.; Miller, Ivan W.

    2008-01-01

    Treatment adherence is a frequent problem in bipolar disorder, with research showing that more than 60% of bipolar patients are at least partially nonadherent to medications. Treatment nonadherence is consistently predictive of a number of negative outcomes in bipolar samples, and the discontinuation of mood stabilizers places these patients at…

  20. Do current national and international guidelines have specific recommendations for older adults with bipolar disorder? A brief report.

    Science.gov (United States)

    Dols, Annemiek; Kessing, Lars Vedel; Strejilevich, Sergio A; Rej, Soham; Tsai, Shang-Ying; Gildengers, Ariel G; Almeida, Osvaldo P; Shulman, Kenneth I; Sajatovic, Martha

    2016-12-01

    Older adults with bipolar disorder (OABD) are a growing segment of patients with bipolar disorder (BD) for which specific guidelines are warranted. Although, OABD are frequently excluded from randomized controlled trials due to their age or somatic comorbidity, more treatment data from a variety of sources have become available in recent years. It is expected that at least some of this emerging information on OABD would be incorporated into treatment guidelines available to clinicians around the world. The International Society of Bipolar Disorders OABD task force compiled and compared recommendations from current national and international guidelines that specifically address geriatric or older individuals with BD (from year 2005 onwards). There were 34 guidelines, representing six continents and 19 countries. The majority of guidelines had no separate section on OABD. General principles for treating OABD with medication are recommended to be similar to those for younger adults, with special caution for side effects due to somatic comorbidity and concomitant medications. Therapeutic lithium serum levels are suggested to be lower but recommendations are very general and mostly not informed by specific research evidence. There is a lack of emphasis of OABD-specific issues in existing guidelines. Given the substantial clinical heterogeneity in BD across the life span, along with the rapidly expanding population of older individuals worldwide, and limited mental health workforce with geriatric expertise, it is critical that additional effort and resources be devoted to studying treatment interventions specific to OABD and that treatment guidelines reflect research findings. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.

  1. Metabolic syndrome in subjects with bipolar disorder and major depressive disorder in a current depressive episode: Population-based study: Metabolic syndrome in current depressive episode.

    Science.gov (United States)

    Moreira, Fernanda Pedrotti; Jansen, Karen; Cardoso, Taiane de Azevedo; Mondin, Thaíse Campos; Magalhães, Pedro Vieira da Silva; Kapczinski, Flávio; Souza, Luciano Dias de Mattos; da Silva, Ricardo Azevedo; Oses, Jean Pierre; Wiener, Carolina David

    2017-09-01

    To assess the differences in the prevalence of the metabolic syndrome (MetS) and their components in young adults with bipolar disorder (BD) and major depressive disorder (MDD) in a current depressive episode. This was a cross-sectional study with young adults aged 24-30 years old. Depressive episode (bipolar or unipolar) was assessed using the Mini International Neuropsychiatric Interview - Plus version (MINI Plus). The MetS was assessed using the National Cholesterol Education Program Adult Treatment Panel III (NCEP/ATP III). The sample included 972 subjects with a mean age of 25.81 (±2.17) years. Both BD and MDD patients showed higher prevalence of MetS compared to the population sample (BD = 46.9%, MDD = 35.1%, population = 22.1%, p obesity were observed in both BD and MDD individuals with current depressive episode compared to the general population. Moreover, there was a significant difference on BMI values in the case of BD and MDD subjects (p = 0.016). Metabolic components were significantly associated with the presence of depressive symptoms, independently of the diagnosis. Copyright © 2017. Published by Elsevier Ltd.

  2. Improvement of Current Gain in Triple Ion Implanted 4H-SiC Bipolar Junction Transistor with Etched Extrinsic Base Regions

    Science.gov (United States)

    Tajima, Taku; Nakamura, Tadashi; Satoh, Masataka; Nakamura, Tohru

    We demonstrate triple ion implanted 4H-SiC bipolar junction transistor (BJT). By etching the extrinsic base regions using inductively coupled plasma dry etching, the characteristics of triple ion implanted 4H-SiC BJT were significantly improved. Maximum common emitter current gain was improved from 1.7 to 7.5.

  3. Protection of pacemaker wearers: effects on magnetic fields on the operation of implanted cardiac pacemakers

    International Nuclear Information System (INIS)

    Souques, M.; Lambrozo, J.; Frank, R.; Himbert, C.

    2002-01-01

    The aim of this study was to assess the changes in the behavior of cardiac pacemakers exposed to 50 and 60 Hz magnetic fields generated by industrial current and 20 to 50 khz magnetic fields generated by a household in a booming period - the induction cook top - and to study the incidence of these changes in a population of subjects with implanted pacemakers. This will enabled to give patients advices about dealing with electric transport lines and facilities and with induction cook tops and to advise manufacturers about the risks involved

  4. Magnetic bipolar transistor

    OpenAIRE

    Fabian, Jaroslav; Zutic, Igor; Sarma, S. Das

    2003-01-01

    A magnetic bipolar transistor is a bipolar junction transistor with one or more magnetic regions, and/or with an externally injected nonequilibrium (source) spin. It is shown that electrical spin injection through the transistor is possible in the forward active regime. It is predicted that the current amplification of the transistor can be tuned by spin.

  5. Biological Rhythms Workshop IB: neurophysiology of SCN pacemaker function.

    Science.gov (United States)

    Kuhlman, S J

    2007-01-01

    Pacemakers are functional units capable of generating oscillations that synchronize downstream rhythms. In mammals, the suprachiasmatic nucleus (SCN) of the hypothalamus is a circadian pacemaker composed of individual neurons that intrinsically express a near 24-hour rhythm in gene expression. Rhythmic gene expression is tightly coupled to a rhythm in spontaneous firing rate via intrinsic daily regulation of potassium current. Recent progress in the field indicates that SCN pacemaking is a specialized property that emerges from intrinsic features of single cells, structural connectivity among cells, and activity dynamics within the SCN. The focus of this chapter is on how Nature built a functional pacemaker from many individual oscillators that is capable of coordinating the daily timing of essential brain and physiological processes.

  6. Pacemaker Use Following Heart Transplantation

    Science.gov (United States)

    Mallidi, Hari R.; Bates, Michael

    2017-01-01

    Background: The incidence of permanent pacemaker implantation after orthotopic heart transplantation has been reported to be 2%-24%. Transplanted hearts usually exhibit sinus rhythm in the operating room following reperfusion, and most patients do not exhibit significant arrhythmias during the postoperative period. However, among the patients who do exhibit abnormalities, pacemakers may be implanted for early sinus node dysfunction but are rarely used after 6 months. Permanent pacing is often required for atrioventricular block. A different cohort of transplant patients presents later with bradycardia requiring pacemaker implantation, reported to occur in approximately 1.5% of patients. The objectives of this study were to investigate the indications for pacemaker implantation, compare the need for pacemakers following bicaval vs biatrial anastomosis, and examine the long-term outcomes of heart transplant patients who received pacemakers. Methods: For this retrospective, case-cohort, single-institution study, patients were identified from clinical research and administrative transplant databases. Information was supplemented with review of the medical records. Standard statistical techniques were used, with chi-square testing for categorical variables and the 2-tailed t test for continuous variables. Survival was compared with the use of log-rank methods. Results: Between January 1968 and February 2008, 1,450 heart transplants were performed at Stanford University. Eighty-four patients (5.8%) were identified as having had a pacemaker implanted. Of these patients, 65.5% (55) had the device implanted within 30 days of transplantation, and 34.5% (29) had late implantation. The mean survival of patients who had an early pacemaker implant was 6.4 years compared to 7.7 years for those with a late pacemaker implant (Ppacemaker implantation. Starting in 1997, a bicaval technique was used for implantation. The incidence of pacemaker implantation by technique was 2.0% for

  7. A novel 4H-SiC lateral bipolar junction transistor structure with high voltage and high current gain

    Science.gov (United States)

    Deng, Yong-Hui; Xie, Gang; Wang, Tao; Sheng, Kuang

    2013-09-01

    In this paper, a novel structure of a 4H-SiC lateral bipolar junction transistor (LBJT) with a base field plate and double RESURF in the drift region is presented. Collector-base junction depletion extension in the base region is restricted by the base field plate. Thin base as well as low base doping of the LBJT therefore can be achieved under the condition of avalanche breakdown. Simulation results show that thin base of 0.32 μm and base doping of 3 × 1017 cm-3 are obtained, and corresponding current gain is as high as 247 with avalanche breakdown voltage of 3309 V when the drift region length is 30 μm. Besides, an investigation of a 4H-SiC vertical BJT (VBJT) with comparable breakdown voltage (3357 V) shows that the minimum base width of 0.25 μm and base doping as high as 8 × 1017 cm-3 contribute to a maximum current gain of only 128.

  8. Defibrillator/monitor/pacemakers.

    Science.gov (United States)

    1998-02-01

    This study updates our May-June 1993 Evaluation of defibrillator/monitor/pacemakers, published in Health Devices 22(5-6), in which we tested eight units from six suppliers. For this Update Evaluation, we tested three additional units, each from a different supplier. We also present update information, including some new ratings, for most of the previously evaluated units. We judged the new units against the same basic criteria and rated and ranked them using the same scheme--with some minor revisions--as in our original Evaluation. We judged the suitability of these units for three primary clinical applications: (1) general crash-cart use, (2) prehospital (emergency medical service [EMS]) use, and (3) in-hospital transport use. Because our criteria have changed slightly since the original study, we have repeated them in this issue. The test methods have not changed significantly and can be found in the original 1993 Evaluation. For more detailed information about this technology, the environments in which these units are used, and the factors to consider when selecting this type of device, we encourage readers to refer to the following sections in the original Evaluation: the Clinical Perspective "The Importance of Early Defibrillation"; the Clinical and Technical Overview; and the Selection and Use Guide for Defibrillator/Monitor/Pacemakers.

  9. High current gain 4H-SiC bipolar junction transistor

    Science.gov (United States)

    Yourun, Zhang; Jinfei, Shi; Ying, Liu; Chengchun, Sun; Fei, Guo; Bo, Zhang

    2016-04-01

    A novel 4H-SiC BJT of high current gain with a suppressing surface traps effect has been proposed. It is effective to improve the current gain due to the lower electrons density in the surface region by extending the emitter metal to overlap the passivation layer on the extrinsic base surface. The electrons trapped in the extrinsic base surface induce the degeneration of SiC BJTs device performance. By modulating the electron recombination rate, the novel structure can increase the current gain to 63.2% compared with conventional ones with the compatible process technology. Optimized sizes are an overlapped metal length of 4 μm, as well as an oxide layer thickness of 50 nm. Project supported by the National Natural Science Foundation of China (Nos. 61306093, 61401075).

  10. Optical beam induced current measurements based on two-photon absorption process in 4H-SiC bipolar diodes

    Energy Technology Data Exchange (ETDEWEB)

    Hamad, H.; Raynaud, C.; Bevilacqua, P.; Tournier, D.; Planson, D. [Ampère Laboratory - UMR 5005, 21, Avenue Jean Capelle, 69621 Villeurbanne Cedex (France); Vergne, B. [Franco-Allemand Institute of Saint-Louis ISL, 5, Rue du Général Cassagnou, 68300 Saint-Louis (France)

    2014-02-24

    Using a pulsed green laser with a wavelength of 532 nm, a duration pulse of ∼1 ns, and a mean power varying between 1 and 100 mW, induced photocurrents have been measured in 4H-SiC bipolar diodes. Considering the photon energy (2.33 eV) and the bandgap of 4H-SiC (3.2 eV), the generation of electron-hole pair by the conventional single photon absorption process should be negligible. The intensity of the measured photocurrents depends quadratically on the power beam intensity. This clearly shows that they are generated using two-photon absorption process. As in conventional OBIC (Optical Beam Induced Current), the measurements give an image of the electric field distribution in the structure under test, and the minority carrier lifetime can be extracted from the decrease of the photocurrent at the edge of the structure. The extracted minority carrier lifetime of 210 ns is consistent with results obtained in case of single photon absorption.

  11. Optical beam induced current measurements based on two-photon absorption process in 4H-SiC bipolar diodes

    International Nuclear Information System (INIS)

    Hamad, H.; Raynaud, C.; Bevilacqua, P.; Tournier, D.; Planson, D.; Vergne, B.

    2014-01-01

    Using a pulsed green laser with a wavelength of 532 nm, a duration pulse of ∼1 ns, and a mean power varying between 1 and 100 mW, induced photocurrents have been measured in 4H-SiC bipolar diodes. Considering the photon energy (2.33 eV) and the bandgap of 4H-SiC (3.2 eV), the generation of electron-hole pair by the conventional single photon absorption process should be negligible. The intensity of the measured photocurrents depends quadratically on the power beam intensity. This clearly shows that they are generated using two-photon absorption process. As in conventional OBIC (Optical Beam Induced Current), the measurements give an image of the electric field distribution in the structure under test, and the minority carrier lifetime can be extracted from the decrease of the photocurrent at the edge of the structure. The extracted minority carrier lifetime of 210 ns is consistent with results obtained in case of single photon absorption

  12. Ultra-high resolution steady-state micro-thermometry using a bipolar direct current reversal technique

    Science.gov (United States)

    Wu, Jason Yingzhi; Wu, Wei; Pettes, Michael Thompson

    2016-09-01

    The suspended micro-thermometry measurement technique is one of the most prominent methods for probing the in-plane thermal conductance of low dimensional materials, where a suspended microdevice containing two built-in platinum resistors that serve as both heater and thermometer is used to measure the temperature and heat flow across a sample. The presence of temperature fluctuations in the sample chamber and background thermal conductance through the device, residual gases, and radiation are dominant sources of error when the sample thermal conductance is comparable to or smaller than the background thermal conductance, on the order of 300 pW/K at room temperature. In this work, we present a high resolution thermal conductance measurement scheme in which a bipolar direct current reversal technique is adopted to replace the lock-in technique. We have demonstrated temperature resolution of 1.0-2.6 mK and thermal conductance resolution of 1.7-26 pW/K over a temperature range of 30-375 K. The background thermal conductance of the suspended microdevice is determined accurately by our method and allows for straightforward isolation of this parasitic signal. This simple and high-throughput measurement technique yields an order of magnitude improvement in resolution over similarly configured lock-in amplifier techniques, allowing for more accurate investigation of fundamental phonon transport mechanisms in individual nanomaterials.

  13. Prefronto-Cerebellar Transcranial Direct Current Stimulation Improves Sleep Quality in Euthymic Bipolar Patients: A Brief Report

    Directory of Open Access Journals (Sweden)

    Amedeo Minichino

    2014-01-01

    Full Text Available Introduction. Sleep problems are common in bipolar disorder (BD and may persist during the euthymic phase of the disease. The aim of the study was to improve sleep quality of euthymic BD patients through the administration of prefronto-cerebellar transcranial direct current stimulation (tDCS. Methods. 25 euthymic outpatients with a diagnosis of BD Type I or II have been enrolled in the study. tDCS montage was as follows: cathode on the right cerebellar cortex and anode over the left dorsolateral prefrontal cortex (DLPFC; the intensity of stimulation was set at 2 mA and delivered for 20 min/die for 3 consecutive weeks. The Pittsburgh Sleep Quality Index (PSQI was used to assess sleep quality at baseline and after the tDCS treatment. Results. PSQI total score and all PSQI subdomains, with the exception of “sleep medication,” significantly improved after treatment. Discussion. This is the first study where a positive effect of tDCS on the quality of sleep in euthymic BD patients has been reported. As both prefrontal cortex and cerebellum may play a role in regulating sleep processes, concomitant cathodal (inhibitory stimulation of cerebellum and anodal (excitatory stimulation of DLPFC may have the potential to modulate prefrontal-thalamic-cerebellar circuits leading to improvements of sleep quality.

  14. Influence of D-net (EUROPEAN GSM-standard) cellular telephones on implanted pacemakers in children.

    Science.gov (United States)

    Elshershari, Huda; Celiker, Alpay; Ozer, Sema; Ozme, Sencan

    2002-09-01

    This study was designed to evaluate possible interactions between digital cellular telephones and implanted pacemakers in children. The study comprised 95 patients (53 males and 42 females) with a mean age of 11.5 +/- 4.6 years (range 1-22 years). The average time from pacemaker implantation was 2.5 years (range 1 month-12 years). Fourteen (15%) devices were dual chamber and the remaining were single chamber pacemakers. The following companies manufactured the pacemakers tested: Medtronic (n = 42), Telectronics (n = 9), Vitatron (n = 16), Pacesetter (n = 19), CPI (n = 8), and Biotronik (n = 1). All the patients were tested in the supine position during continuous ECG monitoring. After completion of the routine pacemaker check, the effects of the European Global system for mobile communication (GSM) was tested using two cellular telephone models (Ericsson GA 628 and Siemens S 25, 2-W power). For this purpose, atrial and ventricular sensitivity settings were programmed to the most sensitive values, and the tests were carried out in the unipolar and bipolar sensing modes. The evaluation was performed during ringing, switching on/off, and conversation phase with the cellular telephone positioned over the pulse generator and around the pacemaker pocket. A malfunction of the pacemaker was not observed in any patient. Only 1 (1%) of 95 patients showed a brief oversensing problem during calls with the cellular telephone. In this case, an AAIR pacemaker was implanted transvenously in a subcutaneous pocket and the sensing defect occurred only with the unipolar sensing mode and was not reproducible. Once the source of interference was removed, no sensing defect was detected and the patient remained asymptomatic. No symptoms were experienced in this study. The authors believe that pacemaker dependent patients with nonprotected pulse generators manufactured at the beginning of 1990s may be tested by their physicians for possible interferences before they use a digital cellular

  15. Predictors for permanent pacemaker implantation after concomitant surgical ablation for atrial fibrillation.

    Science.gov (United States)

    Pecha, Simon; Schäfer, Timm; Yildirim, Yalin; Ahmadzade, Teymour; Willems, Stephan; Reichenspurner, Hermann; Wagner, Florian Mathias

    2014-03-01

    Concomitant surgical atrial fibrillation (AF) ablation is a safe and feasible procedure, recommended in guidelines. Pacemaker dependency is a known complication of AF ablation. We sought to determine independent predictors for pacemaker implantation after surgical AF ablation. Between January 2003 and November 2012, 594 patients underwent concomitant surgical AF ablation. Various energy sources, including cryoablation (n = 139), unipolar radiofrequency (n = 278), and bipolar radiofrequency (n = 177), were used. Left atrial (n = 463, 77.9%) and biatrial (n = 131, 22.1%) ablation was performed. Univariate and multivariate logistic regression analysis was used to identify independent predictors for pacemaker implantation within 30 days after surgical AF ablation. The mean patient's age was 68.6 ± 9.4 years, and 66.8% were male. No major ablation-related complications occurred. A total of 41 (6.9%) of patients received pacemaker implantation during the 30-day follow-up period. Indications for pacemaker implantation were atrioventricular block in 25 (60.9%) of patients, sinus bradycardia or sinus arrest in 9 (22.0%) of patients, and bradyarrhythmia in 7 (17.1%) of patients. Demographic data, type of surgical procedure, and type of energy source did not have a significant impact on pacemaker implantation rate. However, biatrial ablation led to a significant pacemaker implantation rate compared with isolated left-sided ablation (6.3% vs 13.6%; P = .028). Concomitant surgical AF ablation showed a pacemaker implantation rate of 6.9% after 30-day follow-up. Univariate and multivariate analysis showed biatrial lesion set as the only statistically significant predictor for pacemaker implantation after surgical AF ablation. Copyright © 2014 The American Association for Thoracic Surgery. Published by Mosby, Inc. All rights reserved.

  16. Bipolar Disorder

    Science.gov (United States)

    Bipolar disorder is a serious mental illness. People who have it go through unusual mood changes. They go ... The down feeling is depression. The causes of bipolar disorder aren't always clear. It runs in families. ...

  17. Bipolar Disorder in Children

    Science.gov (United States)

    2014-01-01

    Although bipolar disorder historically was thought to only occur rarely in children and adolescents, there has been a significant increase in children and adolescents who are receiving this diagnosis more recently (Carlson, 2005). Nonetheless, the applicability of the current bipolar disorder diagnostic criteria for children, particularly preschool children, remains unclear, even though much work has been focused on this area. As a result, more work needs to be done to further the understanding of bipolar symptoms in children. It is hoped that this paper can assist psychologists and other health service providers in gleaning a snapshot of the literature in this area so that they can gain an understanding of the diagnostic criteria and other behaviors that may be relevant and be informed about potential approaches for assessment and treatment with children who meet bipolar disorder criteria. First, the history of bipolar symptoms and current diagnostic criteria will be discussed. Next, assessment strategies that may prove helpful for identifying bipolar disorder will be discussed. Then, treatments that may have relevance to children and their families will be discussed. Finally, conclusions regarding work with children who may have a bipolar disorder diagnosis will be offered. PMID:24800202

  18. Bipolar Disorder in Children

    Directory of Open Access Journals (Sweden)

    Kimberly Renk

    2014-01-01

    Full Text Available Although bipolar disorder historically was thought to only occur rarely in children and adolescents, there has been a significant increase in children and adolescents who are receiving this diagnosis more recently (Carlson, 2005. Nonetheless, the applicability of the current bipolar disorder diagnostic criteria for children, particularly preschool children, remains unclear, even though much work has been focused on this area. As a result, more work needs to be done to further the understanding of bipolar symptoms in children. It is hoped that this paper can assist psychologists and other health service providers in gleaning a snapshot of the literature in this area so that they can gain an understanding of the diagnostic criteria and other behaviors that may be relevant and be informed about potential approaches for assessment and treatment with children who meet bipolar disorder criteria. First, the history of bipolar symptoms and current diagnostic criteria will be discussed. Next, assessment strategies that may prove helpful for identifying bipolar disorder will be discussed. Then, treatments that may have relevance to children and their families will be discussed. Finally, conclusions regarding work with children who may have a bipolar disorder diagnosis will be offered.

  19. Development of the cardiac pacemaker

    Science.gov (United States)

    Liang, Xingqun; Evans, Sylvia M.

    2017-01-01

    The sinoatrial node (SAN) is the dominant pacemaker of the heart. Abnormalities in SAN formation and function can cause sinus arrhythmia, including sick sinus syndrome and sudden death. A better understanding of genes and signaling pathways that regulate SAN development and function is essential to develop more effective treatment to sinus arrhythmia, including biological pacemakers. In this review, we briefly summarize the key processes of SAN morphogenesis during development, and focus on the transcriptional network that drives SAN development. PMID:27770149

  20. Two-dimensional analysis of the interface state effect on current gain for a 4H-SiC bipolar junction transistor

    Science.gov (United States)

    Zhang, You-Run; Zhang, Bo; Li, Zhao-Ji; Deng, Xiao-Chuan

    2010-06-01

    This paper studies two-dimensional analysis of the surface state effect on current gain for a 4H-SiC bipolar junction transistor (BJT). Simulation results indicate the mechanism of current gain degradation, which is surface Fermi level pinning leading to a strong downward bending of the energy bands to form the channel of surface electron recombination current. The experimental results are well-matched with the simulation, which is modeled by exponential distributions of the interface state density replacing the single interface state trap. Furthermore, the simulation reveals that the oxide quality of the base emitter junction interface is very important for 4H-SiC BJT performance.

  1. Safety of the Wearable Cardioverter Defibrillator (WCD) in Patients with Implanted Pacemakers.

    Science.gov (United States)

    Schmitt, Joern; Abaci, Guezine; Johnson, Victoria; Erkapic, Damir; Gemein, Christopher; Chasan, Ritvan; Weipert, Kay; Hamm, Christian W; Klein, Helmut U

    2017-03-01

    The wearable cardioverter defibrillator (WCD) is an important approach for better risk stratification, applied to patients considered to be at high risk of sudden arrhythmic death. Patients with implanted pacemakers may also become candidates for use of the WCD. However, there is a potential risk that pacemaker signals may mislead the WCD detection algorithm and cause inappropriate WCD shock delivery. The aim of the study was to test the impact of different types of pacing, various right ventricular (RV) lead positions, and pacing modes for potential misleading of the WCD detection algorithm. Sixty patients with implanted pacemakers received the WCD for a short time and each pacing mode (AAI, VVI, and DDD) was tested for at least 30 seconds in unipolar and bipolar pacing configuration. In case of triggering the WCD detection algorithm and starting the sequence of arrhythmia alarms, shock delivery was prevented by pushing of the response buttons. In six of 60 patients (10%), continuous unipolar pacing in DDD mode triggered the WCD detection algorithm. In no patient, triggering occurred with bipolar DDD pacing, unipolar and bipolar AAI, and VVI pacing. Triggering was independent of pacing amplitude, RV pacing lead position, and pulse generator implantation site. Unipolar DDD pacing bears a high risk of false triggering of the WCD detection algorithm. Other types of unipolar pacing and all bipolar pacing modes do not seem to mislead the WCD detection algorithm. Therefore, patients with no reprogrammable unipolar DDD pacing should not become candidates for the WCD. © 2016 Wiley Periodicals, Inc.

  2. What patients with bipolar disorder and major depressive disorder perceive as adverse life events precipitating a current major depressive episode

    Directory of Open Access Journals (Sweden)

    Robyn Anne van Schoor

    2015-05-01

    Full Text Available Background. Adverse life events (ALEs as precipitants of a major depressive episode (MDE have been the subject of many studies. These studies indicate an increase in ALEs in the 6 months preceding an MDE. Objectives. The study examined what participants, suffering from major depressive disorder (MDD or bipolar disorder (BD, perceived as the precipitating ALE of a current MDE. The severity and categories of ALEs were compared between these two patient groups. Methods. Consenting, adult inpatients were sourced from Weskoppies Hospital, Steve Biko Academic Hospital, Tshwane District Hospital, Denmar Psychiatric Hospital and Vista Clinic in the Pretoria area. A semi-structured questionnaire was used to obtain demographic data and the diagnosis. Information regarding the course of the disorder, including the number of previous MDEs and the age at which the first MDE occurred, was also obtained. The perceived precipitating ALE was detailed for each participant. A severity value referred to as a Life Change Unit Score (LCU score, based on the Recent Life Changes Questionnaire (RLCQ by Miller and Rahe, was then assigned to each participant’s perceived precipitant. Results. Of the 64 participants, 12.7 % were experiencing a first MDE. In those participants who had experienced prior episodes the average number (standard deviation (SD of previous episodes was 3.86 (2.46. The mean approximate age (SD at first onset of an MDE was 24.81 (10.9 years. The BD group had significantly more previous MDEs than the MDD group. Although the average LCU scores were higher in the BD group than the MDD group this did not reach statistical significance. Therefore, this study could not find a difference in the severity of the perceived precipitants between the BD group and MDD group. However, when the LCU scores were analysed within subcategories of the RLCQ, it was found that participants with BD perceived significantly more problems associated with the workplace as

  3. Pacemakers and Implantable Defibrillators - Multiple Languages

    Science.gov (United States)

    ... 简体中文) Expand Section Pacemaker - 简体中文 (Chinese, Simplified (Mandarin dialect)) Bilingual PDF Health Information Translations Chinese, Traditional (Cantonese dialect) (繁體中文) Expand Section Pacemaker - ...

  4. [Antidepressants in bipolar disorder].

    Science.gov (United States)

    Courtet, P; Samalin, L; Olié, E

    2011-12-01

    Whereas mania defines the bipolar disorder, depression is the major challenge of treatment. In general, depressions are more frequent, longer, with a major prognostic impact in terms of disability and suicide. How should we treat a patient with bipolar depression? Antidepressants are the treatment of choice for depression, but not in the bipolar disorder. In this context, we have traditionally accepted that antidepressants are effective but they were inducing a significant risk of destabilization of the bipolar disorder, because of the transitions to mania and rapid cycling. Current data reconsider both the two aspects of this risk-benefit ratio. The effectiveness of antidepressants finally seems very limited, especially after the more recent studies with a robust methodology. Manic switches and rapid cycling may not be increased, particularly with new antidepressants and mood stabilizer combinations. The current literature reminds us that these course's modalities are inherent to the disease, with numerous risk factors, and among them, exposure to antidepressants. Who are the bipolar patients who only get the benefits of antidepressant treatment? Research will tell. They are in any case limited. How to navigate in our treatment strategies ? By choosing first drugs that demonstrated efficacy in bipolar depression. When the situation is more complex, "primum non nocere" should lead to support the prescription of the antidepressant in association with mood stabilizer. Copyright © 2011 L’Encéphale. Published by Elsevier Masson SAS.. All rights reserved.

  5. Effects of irradiation on the components of implantable pacemakers

    CERN Document Server

    Kawamura, S; Kuga, N; Shiba, T; Hirose, T; Fujimoto, H; Toyoshima, T; Hyodo, K; Matoba, M

    2003-01-01

    The purpose of this study was to examine the effects of irradiation on implantable pacemaker components. The pacemaker was divided into three components: lead wire and electrode, battery, and electrical circuit, and each component was irradiated by X-ray and electron beams, respectively. The pacemaker parameters were measured by both telemetry data of the programmer and directly measured data from the output terminal. The following results were obtained. For the lead wire and electrode, there was no effect on the pacemaker function due to irradiation by X-ray and electron beams. In the case of battery irradiation, there was no change in battery voltage or current up to 236 Gy X-ray dose. In the electrical circuit, the pacemaker reverted to the regular beating rate (fixed-rate mode) immediately after the start of X-ray irradiation, and it continued in this mode during irradiation. In patients with their own heartbeat rhythm, changing to the fixed-rate mode may cause dangerous conditions such as ventricular fib...

  6. Wireless power transfer for a pacemaker application.

    Science.gov (United States)

    Vulfin, Vladimir; Sayfan-Altman, Shai; Ianconescu, Reuven

    2017-05-01

    An artificial pacemaker is a small medical device that uses electrical impulses, delivered by electrodes contracting the heart muscles, to regulate the beating of the heart. The pacemaker is implanted under the skin, and uses for many years regular non-rechargeable batteries. However, the demand for rechargeable batteries in pacemakers increased, and the aim of this work is to design an efficient charging system for pacemakers.

  7. Early Intervention in Bipolar Disorder.

    Science.gov (United States)

    Vieta, Eduard; Salagre, Estela; Grande, Iria; Carvalho, André F; Fernandes, Brisa S; Berk, Michael; Birmaher, Boris; Tohen, Mauricio; Suppes, Trisha

    2018-01-24

    Bipolar disorder is a recurrent disorder that affects more than 1% of the world population and usually has its onset during youth. Its chronic course is associated with high rates of morbidity and mortality, making bipolar disorder one of the main causes of disability among young and working-age people. The implementation of early intervention strategies may help to change the outcome of the illness and avert potentially irreversible harm to patients with bipolar disorder, as early phases may be more responsive to treatment and may need less aggressive therapies. Early intervention in bipolar disorder is gaining momentum. Current evidence emerging from longitudinal studies indicates that parental early-onset bipolar disorder is the most consistent risk factor for bipolar disorder. Longitudinal studies also indicate that a full-blown manic episode is often preceded by a variety of prodromal symptoms, particularly subsyndromal manic symptoms, therefore supporting the existence of an at-risk state in bipolar disorder that could be targeted through early intervention. There are also identifiable risk factors that influence the course of bipolar disorder, some of them potentially modifiable. Valid biomarkers or diagnosis tools to help clinicians identify individuals at high risk of conversion to bipolar disorder are still lacking, although there are some promising early results. Pending more solid evidence on the best treatment strategy in early phases of bipolar disorder, physicians should carefully weigh the risks and benefits of each intervention. Further studies will provide the evidence needed to finish shaping the concept of early intervention.

  8. 21 CFR 870.3670 - Pacemaker charger.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Pacemaker charger. 870.3670 Section 870.3670 Food... DEVICES CARDIOVASCULAR DEVICES Cardiovascular Prosthetic Devices § 870.3670 Pacemaker charger. (a) Identification. A pacemaker charger is a device used transcutaneously to recharge the batteries of a rechargeable...

  9. 21 CFR 870.3700 - Pacemaker programmers.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Pacemaker programmers. 870.3700 Section 870.3700...) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Prosthetic Devices § 870.3700 Pacemaker programmers. (a) Identification. A pacemaker programmer is a device used to change noninvasively one or more of...

  10. Automatic Capture Verification in Pacemakers (Autocapture – Utility and Problems

    Directory of Open Access Journals (Sweden)

    Ruth Kam

    2004-04-01

    Full Text Available The concept of a closed – loop feedback system, that would automatically assess pacing threshold and self -adjust pacing output to ensure consistent myocardial capture, has many appeals. Enhancing patient safety in cases of an unexpected rise in threshold, reduced current drain, hence prolonging battery longevity and reducing the amount of physician intervention required are just some of the advantages. Autocapture (AC is a proprietary algorithm developed by St Jude Medical CRMD, Sylmar, CA, USA, (SJM that was the first to commercially provide these automatic functions in a single chamber pacemaker (Microny and Regency, and subsequently in a dual chamber pacemaker (Affinity, Entity and Identity family of pacemakers. This article reviews the conditions necessary for AC verification and performance and the problems encountered in clinical practice.

  11. Syncope in Patients with Pacemakers

    OpenAIRE

    Sutton, Richard

    2015-01-01

    Syncope in a pacemaker patient is a serious symptom but it is rarely due a pacemaker system malfunction. Syncope occurs in about 5 % of patients paced for atrioventricular (AV) block in 5 years, 18% in those paced for sinus node disease in 10 years, 20 % of those paced for carotid sinus syndrome in 5 years and 5–55 % of those older patients paced for vasovagal syncope in 2 years. The vastly different results in vasovagal syncope depend on the results of tilt testing, where those with negative...

  12. Noise-induced effects on multicellular biopacemaker spontaneous activity: Differences between weak and strong pacemaker cells

    Science.gov (United States)

    Aghighi, Alireza; Comtois, Philippe

    2017-09-01

    Self-organization of spontaneous activity of a network of active elements is important to the general theory of reaction-diffusion systems as well as for pacemaking activity to initiate beating of the heart. Monolayer cultures of neonatal rat ventricular myocytes, consisting of resting and pacemaker cells, exhibit spontaneous activation of their electrical activity. Similarly, one proposed approach to the development of biopacemakers as an alternative to electronic pacemakers for cardiac therapy is based on heterogeneous cardiac cells with resting and spontaneously beating phenotypes. However, the combined effect of pacemaker characteristics, density, and spatial distribution of the pacemaker cells on spontaneous activity is unknown. Using a simple stochastic pattern formation algorithm, we previously showed a clear nonlinear dependency of spontaneous activity (occurrence and amplitude of spontaneous period) on the spatial patterns of pacemaker cells. In this study, we show that this behavior is dependent on the pacemaker cell characteristics, with weaker pacemaker cells requiring higher density and larger clusters to sustain multicellular activity. These multicellular structures also demonstrated an increased sensitivity to voltage noise that favored spontaneous activity at lower density while increasing temporal variation in the period of activity. This information will help researchers overcome the current limitations of biopacemakers.

  13. [Wide QRS tachycardia preceded by pacemaker spikes].

    Science.gov (United States)

    Romero, M; Aranda, A; Gómez, F J; Jurado, A

    2014-04-01

    The differential diagnosis and therapeutic management of wide QRS tachycardia preceded by pacemaker spike is presented. The pacemaker-mediated tachycardia, tachycardia fibrillo-flutter in patients with pacemakers, and runaway pacemakers, have a similar surface electrocardiogram, but respond to different therapeutic measures. The tachycardia response to the application of a magnet over the pacemaker could help in the differential diagnosis, and in some cases will be therapeutic, as in the case of a tachycardia-mediated pacemaker. Although these conditions are diagnosed and treated in hospitals with catheterization laboratories using the application programmer over the pacemaker, patients presenting in primary care clinic and emergency forced us to make a diagnosis and treat the haemodynamically unstable patient prior to referral. Copyright © 2012 Sociedad Española de Médicos de Atención Primaria (SEMERGEN). Publicado por Elsevier España. All rights reserved.

  14. First Degree Pacemaker Exit Block

    Directory of Open Access Journals (Sweden)

    Johnson Francis

    2016-10-01

    Full Text Available Usually atrial and ventricular depolarizations follow soon after the pacemaker stimulus (spike on the ECG. But there can be an exit block due to fibrosis at the electrode - tissue interface at the lead tip. This can increase the delay between the spike and atrial or ventricular depolarization.

  15. Bipolar and unipolar resistive switching behaviors of sol–gel-derived SrTiO3 thin films with different compliance currents

    International Nuclear Information System (INIS)

    Tang, M H; Wang, Z P; Zeng, Z Q; Xu, X L; Wang, G Y; Zhang, L B; Xiao, Y G; Yang, S B; Jiang, B; Li, J C; He, J

    2011-01-01

    The SrTiO 3 (STO) thin films on a Pt/Ti/SiO 2 /Si substrate were synthesized using a sol–gel method to form a metal–insulator–metal structure. This device shows the bipolar resistance switching (BRS) behavior for a compliance current I cc of less than 0.1 mA but exhibits soft breakdown at a higher level of compliance current. A transition from the BRS behavior to the stable unipolar resistive switching behavior (URS) was also observed. We found that the BRS behavior may be controlled by the structure interface while the URS behavior is likely bulk controlled. Our study indicates that the external compliance current is a key factor in resistance switching phenomenon of STO thin films

  16. Effects of base doping and carrier lifetime on differential current gain and temperature coefficient of 4H-SiC power bipolar junction transistors

    Science.gov (United States)

    Niu, X.; Fardi, H.

    2012-04-01

    4H-SiC NPN bipolar junction transistor (BJT) is studied systematically by performing two-dimensional numerical simulations. Several design issues are discussed. Depending on the doping concentration of the base and the carrier lifetimes, both positive and negative temperature coefficients in the common emitter current gain could exist in 4H-SiC NPN BJTs with aluminium-doped base. The temperature coefficients of the current gain at different base doping concentrations and different carrier lifetimes have been determined. A high base doping concentration can reduce the requirement for the carrier lifetime in order to obtain negative temperature coefficient in current gain. Device simulations are performed to evaluate the carrier lifetimes by fitting the measured output IC -VCE curves. An excellent fitting is obtained and the base electron lifetime and the emitter hole lifetime are extracted to be about 22 and 5.7 ns, respectively.

  17. Pacemakers and Implantable Defibrillators: MedlinePlus Health Topic

    Science.gov (United States)

    ... ClinicalTrials.gov: Pacemaker, Artificial (National Institutes of Health) Journal Articles References and abstracts from MEDLINE/PubMed (National ... Leadless Cardiac Pacemakers: The Next Evolution in Pacemaker Technology. ... on Pacemakers and Implantable Defibrillators is the National Heart, Lung, and Blood Institute Other Languages Find health information in languages other than English on Pacemakers and ...

  18. The “Funny” Current (If Inhibition by Ivabradine at Membrane Potentials Encompassing Spontaneous Depolarization in Pacemaker Cells

    Directory of Open Access Journals (Sweden)

    Yael Yaniv

    2012-07-01

    Full Text Available Recent clinical trials have shown that ivabradine (IVA, a drug that inhibits the funny current (If in isolated sinoatrial nodal cells (SANC, decreases heart rate and reduces morbidity and mortality in patients with cardiovascular diseases. While IVA inhibits If, this effect has been reported at essentially unphysiological voltages, i.e., those more negative than the spontaneous diastolic depolarization (DD between action potentials (APs. We tested the relative potency of IVA to block If over a wide range of membrane potentials, including those that encompass DD governing to the SANC spontaneous firing rate. A clinically relevant IVA concentration of 3 μM to single, isolated rabbit SANC slowed the spontaneous AP firing rate by 15%. During voltage clamp the maximal If was 18 ± 3 pA/pF (at −120 mV and the maximal If reduction by IVA was 60 ± 8% observed at −92 ± 4 mV. At the maximal diastolic depolarization (~−60 mV If amplitude was only −2.9 ± 0.4 pA/pF, and was reduced by only 41 ± 6% by IVA. Thus, If amplitude and its inhibition by IVA at physiologically relevant membrane potentials are substantially less than that at unphysiological (hyperpolarized membrane potentials. This novel finding more accurately describes how IVA affects SANC function and is of direct relevance to numerical modeling of SANC automaticity.

  19. Bipolar disorder

    Science.gov (United States)

    ... of pleasure in activities once enjoyed Loss of self-esteem Thoughts of death or suicide Trouble getting to ... other. This is called rapid cycling. Exams and Tests To diagnose bipolar disorder, the provider may do ...

  20. Bipolar disorder

    Directory of Open Access Journals (Sweden)

    F Colin

    2013-08-01

    Full Text Available Bipolar disorder (BD presents in different phases over time and is oftencomplicated by comorbid conditions such as substance-use disordersand anxiety disorders. Treatment usually involves pharmacotherapywith combinations of different classes of medications and frequentmedication revisions.

  1. Validation of the Russian version of the Hypomania Checklist (HCL-32) for the detection of Bipolar II disorder in patients with a current diagnosis of recurrent depression.

    Science.gov (United States)

    Mosolov, S N; Ushkalova, A V; Kostukova, E G; Shafarenko, A A; Alfimov, P V; Kostyukova, A B; Angst, J

    2014-02-01

    There are no validated screening tools for Bipolar Disorder (BD) in Russia. To validate the Russian version of the HCL-32 for the detection of Bipolar II disorder (BD II) in patients with Recurrent Depressive Disorder (RDD). 409 patients with a current diagnosis of RDD were recruited. The diagnosis was confirmed by the validated Russian version of the Mini International Neuropsychiatric Interview (MINI). Another investigator interviewed the patients using the НСL-32 questions. The total HCL-32 score in patients with BD II was significantly higher than in patients with RDD: 18.2 (4.22) versus 10.85 (5.81) (pRussian version of the HCL-32 displayed a good ratio of sensitivity to specificity and can be recommended as a validated screening instrument. An 8-item version of HCL needs further research. Limitations include the specific nature of the sample, the HCL-32 assessment carried out by a psychiatrist, no comparison with other BD screening scales. The results of the 8-item version may be sample and culture dependent. © 2013 Elsevier B.V. All rights reserved.

  2. A Review on Pacemakers: Device Types, Operating Modes and Pacing Pulses. Problems Related to the Pacing Pulses Detection

    Directory of Open Access Journals (Sweden)

    Valentin Tsibulko

    2014-06-01

    Full Text Available A pacemaker is a small battery-operated medical device that delivers electrical impulses to the heart in order to guarantee regular contractions. Depending on the number of active leads the pacemakers are single chamber, dual chamber and bi-ventricular. According to their programming the devices could be with fixed-rate, 'on demand' and rate-responsitive. The operating mode of the pacemaker depends on the paced chamber, the sensed chamber, the response to a sensed electrical signal and the rate modulation. Two types of pacing are recognized - unipolar and bipolar, represented with different pacing artifacts in the ECG signal. The pacing pulse on the skin surface usually have very fast rising edges of the order of 10 µs or less and could be as small as few hundreds µV. The pacing artifacts detection is important since they indicate the presence of a pacemaker and help to evaluate the reaction of the heart. All pertinent medical standards require the pacing artifacts to be captured and indicated on the screen of the device. This paper presents a short review on pacemakers - reasons for implementation, device types, different operation modes and pacing pulses. It reveals some common problems with the detection of pacemaker's artifacts.

  3. Spanish Pacemaker Registry. 14th Official Report of the Spanish Society of Cardiology Working Group on Cardiac Pacing (2016).

    Science.gov (United States)

    Cano Pérez, Óscar; Pombo Jiménez, Marta; Fidalgo Andrés, María Luisa; Lorente Carreño, Diego; Coma Samartín, Raúl

    2017-12-01

    This report describes the results of analysis of implanted pacemakers reported to the Spanish Pacemaker Registry. The analysis was based on information provided by the European Pacemaker Identification Card. Information was received from 115 hospitals, with a total of 12 697 cards, representing 32.3% of the estimated activity. Use of conventional and resynchronization pacemakers was 818 and 79 units per million inhabitants, respectively. A total of 200 leadless pacemakers were implanted. The mean age of the patients receiving an implant was 77.8 years, and 52% of devices were implanted in persons older than 80 years. In all, 74.9% were first implants and 23.4% corresponded to generator exchange. Endocardial leads were bipolar, 82.9% with active fixation, and 16.1% had magnetic resonance imaging protection. Most patients received bicameral sequential pacing, although single chamber pacing VVI(R) was used in 26.7% of the patients with sick sinus syndrome and in 23.8% of those with atrioventricular block, despite sinus rhythm. Total use of pacemaker generators in Spain has increased by 1.6% compared with 2015. Most implanted leads have active fixation and less than 20% have magnetic resonance imaging protection. Age and sex directly influenced pacing mode selection, which could be improved in around 32% of patients. Copyright © 2017 Sociedad Española de Cardiología. Published by Elsevier España, S.L.U. All rights reserved.

  4. Syncope in Patients with Pacemakers.

    Science.gov (United States)

    Sutton, Richard

    2015-12-01

    Syncope in a pacemaker patient is a serious symptom but it is rarely due a pacemaker system malfunction. Syncope occurs in about 5 % of patients paced for atrioventricular (AV) block in 5 years, 18% in those paced for sinus node disease in 10 years, 20 % of those paced for carotid sinus syndrome in 5 years and 5-55 % of those older patients paced for vasovagal syncope in 2 years. The vastly different results in vasovagal syncope depend on the results of tilt testing, where those with negative tests approach results in pacing for AV block and those with a positive tilt test show no better results than with no pacemaker. The implication of tilt results is that a hypotensive tendency is clearly demonstrated by tilt positivity pointing to syncope recurrence with hypotension. This problem may be addressed by treatment with vasoconstrictor drugs in those who are suited or, more commonly, a reduction or cessation of hypotensive therapy in hypertensive patients. Other causes of syncope such as tachyarrhythmias are rare. The clinical approach to patients who report syncope is detailed.

  5. The nuclear pacemaker: Is renewed interest warranted

    International Nuclear Information System (INIS)

    Parsonnet, V.; Berstein, A.D.; Perry, G.Y.

    1990-01-01

    From 1973 through 1987, 155 radioisotope-powered nuclear pacemakers were implanted in 132 patients at the Newark Beth Israel Medical Center. The longevity of the first 15 devices, all of which were fixed-rate (VOO) pacemakers, was significantly better than that of 15 lithium-chemistry demand (VVI) pacemakers used as control devices (p = 0.0002). Of the entire cohort of 155 nuclear pacemakers, 136 were VVI devices and 19 were VOO units. The patients with VOO pacemakers needed reoperations more often than did those with VVI pacemakers, chiefly for mode change (p less than 0.001). Power-source failure was observed in only 1 case, but 47 nuclear pacemakers were removed for other reasons, including component malfunction (15 units), mode change (12 units), high pacing thresholds (8 units) and lead or connector problems (5 units). The actuarial survival at 15 years was 99% for power sources and 82% for the entire pacing systems (pulse generators plus leads). The frequency of malignancy was similar to that of the population at large and primary tumor sites were randomly distributed. Deaths most commonly were due to cardiac causes (68%). Thus, nuclear pacemakers are safe and reliable and their greater initial cost appears to be offset by their longevity and the resulting decrease in the frequency of reoperations. It is reasonable to suggest that further use be made of long-lasting nuclear power sources for modern pacemakers and other implantable rhythm-management devices

  6. On the Evolution of the Cardiac Pacemaker

    Science.gov (United States)

    Burkhard, Silja; van Eif, Vincent; Garric, Laurence; Christoffels, Vincent M.; Bakkers, Jeroen

    2017-01-01

    The rhythmic contraction of the heart is initiated and controlled by an intrinsic pacemaker system. Cardiac contractions commence at very early embryonic stages and coordination remains crucial for survival. The underlying molecular mechanisms of pacemaker cell development and function are still not fully understood. Heart form and function show high evolutionary conservation. Even in simple contractile cardiac tubes in primitive invertebrates, cardiac function is controlled by intrinsic, autonomous pacemaker cells. Understanding the evolutionary origin and development of cardiac pacemaker cells will help us outline the important pathways and factors involved. Key patterning factors, such as the homeodomain transcription factors Nkx2.5 and Shox2, and the LIM-homeodomain transcription factor Islet-1, components of the T-box (Tbx), and bone morphogenic protein (Bmp) families are well conserved. Here we compare the dominant pacemaking systems in various organisms with respect to the underlying molecular regulation. Comparative analysis of the pathways involved in patterning the pacemaker domain in an evolutionary context might help us outline a common fundamental pacemaker cell gene programme. Special focus is given to pacemaker development in zebrafish, an extensively used model for vertebrate development. Finally, we conclude with a summary of highly conserved key factors in pacemaker cell development and function. PMID:29367536

  7. Pacemaker rate and depolarization block in nigral dopamine neurons: a somatic sodium channel balancing act

    Science.gov (United States)

    Tucker, Kristal R.; Huertas, Marco A.; Horn, John P.; Canavier, Carmen C.; Levitan, Edwin S.

    2012-01-01

    Midbrain dopamine (DA) neurons are slow intrinsic pacemakers that undergo depolarization (DP) block upon moderate stimulation. Understanding DP block is important because it has been correlated with the clinical efficacy of chronic antipsychotic drug treatment. Here we describe how voltage-gated sodium (NaV) channels regulate DP block and pacemaker activity in DA neurons of the substantia nigra using rat brain slices. The distribution, density and gating of NaV currents were manipulated by blocking native channels with tetrodotoxin and by creating virtual channels and anti-channels with dynamic clamp. Although action potentials initiate in the axon initial segment (AIS) and NaV channels are distributed in multiple dendrites, selective reduction of NaV channel activity in the soma was sufficient to decrease pacemaker frequency and increase susceptibility to DP block. Conversely, increasing somatic NaV current density raised pacemaker frequency and lowered susceptibility to DP block. Finally, when NaV currents were restricted to the soma, pacemaker activity occurred at abnormally high rates due to excessive local subthreshold NaV current. Together with computational simulations, these data show that both the slow pacemaker rate and the sensitivity to DP block that characterizes DA neurons result from the low density of somatic NaV channels. More generally, we conclude that the somatodendritic distribution of NaV channels is a major determinant of repetitive spiking frequency. PMID:23077037

  8. Feasibility of pacemaker therapy after dynamic cardiomyoplasty

    NARCIS (Netherlands)

    Van den Berg, MP; Nagelkerke, D; Brouwer, RMHJ; Mulder, H; De Boer, H; Crijns, HJGM

    1999-01-01

    A 54-year-old man presented with total atrioventricular (AV) block 3 months after dynamic cardiomyoplasty was performed because of heart failure due to idiopathic dilated cardiomyopathy. Though the cardiomyostimulator acted as a back-up pacemaker, a DDDR pacemaker was implanted to optimize

  9. On the Evolution of the Cardiac Pacemaker

    NARCIS (Netherlands)

    Burkhard, Silja; van Eif, Vincent; Garric, Laurence; Christoffels, Vincent M; Bakkers, Jeroen

    2017-01-01

    The rhythmic contraction of the heart is initiated and controlled by an intrinsic pacemaker system. Cardiac contractions commence at very early embryonic stages and coordination remains crucial for survival. The underlying molecular mechanisms of pacemaker cell development and function are still not

  10. Biofilm on artificial pacemaker: fiction or reality?

    Science.gov (United States)

    Santos, Ana Paula Azevedo; Watanabe, Evandro; Andrade, Denise de

    2011-11-01

    Cardiac pacing through cardiac pacemaker is one of the most promising alternatives in the treatment of arrhythmias, but it can cause reactions natural or complex reactions, either early or late. This study aimed to describe the scientific evidence on the risk of infection and biofilm formation associated with cardiac pacemaker. This is a study of integrative literature review. It included 14 publications classified into three thematic categories: diagnosis (microbiological and/or clinical), complications and therapy of infections. Staphylococcus epidermidis and Staphylococcus aureus were the microorganisms most frequently isolated. It was not possible to determine the incidence of infection associated with pacemakers, since the studies were generally of prevalence. In terms of therapy, the complete removal of pacemakers stood out, especially in cases of suspected biofilm. Still controversial is the use of systemic antibiotic prophylaxis in reducing the incidence of infection associated with implantation of a pacemaker.

  11. Surgical removal of infected transvenous pacemaker leads.

    Science.gov (United States)

    Frame, R; Brodman, R F; Furman, S; Andrews, C A; Gross, J N

    1993-12-01

    Infection, though uncommon, can be the most lethal of all potential complications following transvenous pacemaker implantation. Eradication of infection associated with pacemakers requires complete removal of all hardware, including inactive leads. Since 1972, 5,089 patients have had 8,508 pacemaker generators implanted at Montefiore Medical Center. There were 91 infections (1.06%); four of our patients required surgical removal. Nine additional patients were referred for surgical removal of infected transvenous pacemaker leads from other institutions. Surgical methods for removal included use of cardiopulmonary bypass or inflow occlusion. Surgery may be safely used in unstable or elderly patients and should not be reserved as a last resort. This article reviews our surgical experience removing infected pacemaker leads at Montefiore Medical Center.

  12. Inward-rectifying potassium (Kir) channels regulate pacemaker activity in spinal nociceptive circuits during early life

    Science.gov (United States)

    Li, Jie; Blankenship, Meredith L.; Baccei, Mark L.

    2013-01-01

    Pacemaker neurons in neonatal spinal nociceptive circuits generate intrinsic burst-firing and are distinguished by a lower “leak” membrane conductance compared to adjacent, non-bursting neurons. However, little is known about which subtypes of leak channels regulate the level of pacemaker activity within the developing rat superficial dorsal horn (SDH). Here we demonstrate that a hallmark feature of lamina I pacemaker neurons is a reduced conductance through inward-rectifying potassium (Kir) channels at physiological membrane potentials. Differences in the strength of inward rectification between pacemakers and non-pacemakers indicate the presence of functionally distinct Kir currents in these two populations at room temperature. However, Kir currents in both groups showed high sensitivity to block by extracellular Ba2+ (IC50 ~ 10 µM), which suggests the presence of ‘classical’ Kir (Kir2.x) channels in the neonatal SDH. The reduced Kir conductance within pacemakers is unlikely to be explained by an absence of particular Kir2.x isoforms, as immunohistochemical analysis revealed the expression of Kir2.1, Kir2.2 and Kir2.3 within spontaneously bursting neurons. Importantly, Ba2+ application unmasked rhythmic burst-firing in ~42% of non-bursting lamina I neurons, suggesting that pacemaker activity is a latent property of a sizeable population of SDH cells during early life. In addition, the prevalence of spontaneous burst-firing within lamina I was enhanced in the presence of high internal concentrations of free Mg2+, consistent with its documented ability to block Kir channels from the intracellular side. Collectively, the results indicate that Kir channels are key modulators of pacemaker activity in newborn central pain networks. PMID:23426663

  13. Resonant Hall effect under generation of a self-sustaining mode of spin current in nonmagnetic bipolar conductors with identical characters between holes and electrons

    Science.gov (United States)

    Sakai, Masamichi; Takao, Hiraku; Matsunaga, Tomoyoshi; Nishimagi, Makoto; Iizasa, Keitaro; Sakuraba, Takahito; Higuchi, Koji; Kitajima, Akira; Hasegawa, Shigehiko; Nakamura, Osamu; Kurokawa, Yuichiro; Awano, Hiroyuki

    2018-03-01

    We have proposed an enhancement mechanism of the Hall effect, the signal of which is amplified due to the generation of a sustaining mode of spin current. Our analytic derivations of the Hall resistivity revealed the conditions indispensable for the observation of the effect: (i) the presence of the transverse component of an effective electric field due to spin splitting in chemical potential in addition to the longitudinal component; (ii) the simultaneous presence of holes and electrons each having approximately the same characteristics; (iii) spin-polarized current injection from magnetized electrodes; (iv) the boundary condition for the transverse current (J c, y = 0). The model proposed in this study was experimentally verified by using van der Pauw-type Hall devices consisting of the nonmagnetic bipolar conductor YH x (x ≃ 2) and TbFeCo electrodes. Replacing Au electrodes with TbFeCo electrodes alters the Hall resistivity from the ordinary Hall effect to the anomalous Hall-like effect with an enhancement factor of approximately 50 at 4 T. We interpreted the enhancement phenomenon in terms of the present model.

  14. Radiotherapy for breast cancer and pacemaker

    International Nuclear Information System (INIS)

    Menard, J.; Campana, F.; Bollet, M.A.; Dendale, R.; Fournier-Bidoz, N.; Marchand, V.; Mazal, A.; Fourquet, A.; Kirova, Y.M.; Kirov, K.M.; Esteve, M.

    2011-01-01

    Purpose. - Patients with permanent cardiac pacemakers occasionally require radiotherapy. Therapeutic Irradiation may cause pacemakers to malfunction due to the effects of ionizing radiation or electromagnetic interference. We studied the breast cancer patients who needed breast and/or chest wall and lymph node irradiation to assess the feasibility and tolerance in this population of patients. Patients and methods. - From November 2008 to December 2009, more than 900 patients received radiotherapy for their breast cancer in our department using megavoltage linear accelerator (X 4-6 MV and electrons). Among them, seven patients were with permanent pacemaker. All patients have been treated to the breast and chest wall and/or lymph nodes. Total dose to breast and/or chest wall was 50 Gy/25 fractions and 46 Gy/23 fractions to lymph nodes. Patients who underwent conserving surgery followed by breast irradiation were boosted when indicated to tumour bed with 16 Gy/8 fractions. All patients were monitored everyday in presence of radiation oncologist to follow the function of their pacemaker. All pacemakers were controlled before and after radiotherapy by the patients' cardiologist. Results. - Seven patients were referred in our department for postoperative breast cancer radiotherapy. Among them, only one patient was declined for radiotherapy and underwent mastectomy without radiotherapy. In four cases the pacemaker was repositioned before the beginning of radiotherapy. Six patients, aged between 48 and 84 years underwent irradiation for their breast cancer. Four patients were treated with conserving surgery followed by breast radiotherapy and two with mastectomy followed by chest wall and internal mammary chain, supra- and infra-clavicular lymph node irradiation. The dose to the pacemaker generator was kept below 2 Gy. There was no pacemaker dysfunction observed during the radiotherapy. Conclusion. - The multidisciplinary work with position change of the pacemaker before

  15. Bipolar Disorder (For Teens)

    Science.gov (United States)

    ... Staying Safe Videos for Educators Search English Español Bipolar Disorder KidsHealth / For Teens / Bipolar Disorder What's in this ... Disorder Print en español Trastorno bipolar What Is Bipolar Disorder? Bipolar disorders are one of several medical conditions ...

  16. Neutrality in bipolar structures

    DEFF Research Database (Denmark)

    Montero, Javier; Rodríguez, J. Tinguaro; Franco, Camilo

    2014-01-01

    In this paper, we want to stress that bipolar knowledge representation naturally allows a family of middle states which define as a consequence different kinds of bipolar structures. These bipolar structures are deeply related to the three types of bipolarity introduced by Dubois and Prade, but our...... approach offers a systematic explanation of how such bipolar structures appear and can be identified....

  17. 21 CFR 870.3620 - Pacemaker lead adaptor.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Pacemaker lead adaptor. 870.3620 Section 870.3620...) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Prosthetic Devices § 870.3620 Pacemaker lead adaptor. (a) Identification. A pacemaker lead adaptor is a device used to adapt a pacemaker lead so that it...

  18. 21 CFR 870.3640 - Indirect pacemaker generator function analyzer.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Indirect pacemaker generator function analyzer... Indirect pacemaker generator function analyzer. (a) Identification. An indirect pacemaker generator function analyzer is an electrically powered device that is used to determine pacemaker function or...

  19. Pacemakers charging using body energy

    Science.gov (United States)

    Bhatia, Dinesh; Bairagi, Sweeti; Goel, Sanat; Jangra, Manoj

    2010-01-01

    Life-saving medical implants like pacemakers and defibrillators face a big drawback that their batteries eventually run out and patients require frequent surgery to have these batteries replaced. With the advent of technology, alternatives can be provided for such surgeries. To power these devices, body energy harvesting techniques may be employed. Some of the power sources are patient's heartbeat, blood flow inside the vessels, movement of the body parts, and the body temperature (heat). Different types of sensors are employed, such as for sensing the energy from the heartbeat the piezoelectric and semiconducting coupled nanowires are used that convert the mechanical energy into electricity. Similarly, for sensing the blood flow energy, nanogenerators driven by ultrasonic waves are used that have the ability to directly convert the hydraulic energy in human body to electrical energy. Another consideration is to use body heat employing biothermal battery to generate electricity using multiple arrays of thermoelectric generators built into an implantable chip. These generators exploit the well-known thermocouple effect. For the biothermal device to work, it needs a 2°C temperature difference across it. But there are many parts of the body where a temperature difference of 5°C exists – typically in the few millimeters just below the skin, where it is planned to place this device. This study focuses on using body heat as an alternative energy source to recharge pacemaker batteries and other medical devices and prevent the possibility of life-risk during repeated surgery. PMID:21814432

  20. Pacemakers charging using body energy.

    Science.gov (United States)

    Bhatia, Dinesh; Bairagi, Sweeti; Goel, Sanat; Jangra, Manoj

    2010-01-01

    Life-saving medical implants like pacemakers and defibrillators face a big drawback that their batteries eventually run out and patients require frequent surgery to have these batteries replaced. With the advent of technology, alternatives can be provided for such surgeries. To power these devices, body energy harvesting techniques may be employed. Some of the power sources are patient's heartbeat, blood flow inside the vessels, movement of the body parts, and the body temperature (heat). Different types of sensors are employed, such as for sensing the energy from the heartbeat the piezoelectric and semiconducting coupled nanowires are used that convert the mechanical energy into electricity. Similarly, for sensing the blood flow energy, nanogenerators driven by ultrasonic waves are used that have the ability to directly convert the hydraulic energy in human body to electrical energy. Another consideration is to use body heat employing biothermal battery to generate electricity using multiple arrays of thermoelectric generators built into an implantable chip. These generators exploit the well-known thermocouple effect. For the biothermal device to work, it needs a 2°C temperature difference across it. But there are many parts of the body where a temperature difference of 5°C exists - typically in the few millimeters just below the skin, where it is planned to place this device. This study focuses on using body heat as an alternative energy source to recharge pacemaker batteries and other medical devices and prevent the possibility of life-risk during repeated surgery.

  1. Pacemakers charging using body energy

    Directory of Open Access Journals (Sweden)

    Dinesh Bhatia

    2010-01-01

    Full Text Available Life-saving medical implants like pacemakers and defibrillators face a big drawback that their batteries eventually run out and patients require frequent surgery to have these batteries replaced. With the advent of technology, alternatives can be provided for such surgeries. To power these devices, body energy harvesting techniques may be employed. Some of the power sources are patient′s heartbeat, blood flow inside the vessels, movement of the body parts, and the body temperature (heat. Different types of sensors are employed, such as for sensing the energy from the heartbeat the piezoelectric and semiconducting coupled nanowires are used that convert the mechanical energy into electricity. Similarly, for sensing the blood flow energy, nanogenerators driven by ultrasonic waves are used that have the ability to directly convert the hydraulic energy in human body to electrical energy. Another consideration is to use body heat employing biothermal battery to generate electricity using multiple arrays of thermoelectric generators built into an implantable chip. These generators exploit the well-known thermocouple effect. For the biothermal device to work, it needs a 2°C temperature difference across it. But there are many parts of the body where a temperature difference of 5°C exists - typically in the few millimeters just below the skin, where it is planned to place this device. This study focuses on using body heat as an alternative energy source to recharge pacemaker batteries and other medical devices and prevent the possibility of life-risk during repeated surgery.

  2. Spanish Pacemaker Registry. Eleventh official report of the Spanish Society of Cardiology Working Group on Cardiac Pacing (2013).

    Science.gov (United States)

    Coma Samartín, Raúl; Cano Pérez, Óscar; Pombo Jiménez, Marta

    2014-12-01

    The present report summarizes the analysis of pacemaker implantation and replacement data sent to the Spanish Pacemaker Registry in 2013, with specific discussion of pacing mode selection. This study was based on information obtained from the European Pacemaker Patient Identification Card. Information was received on 118 hospital centers, with a total of 12 831 cards, or 35% of the estimated activity. There were 755 and 58.1 conventional and resynchronization devices per million population, respectively. The mean age of patients receiving an implant was 77.4 years. Men received 59.5% of first implantations and 56.6% of replacements. Most implantations and generator replacements were performed in patients older than 80 years. Almost all endocardial leads used were bipolar, and 78.7% of leads had an active fixation mechanism. Despite being in sinus rhythm, 24% of patients with sick sinus syndrome and 25% of those with atrioventricular block were paced in VVIR mode. The use of pacemaker generators and resynchronization devices per million population continues to increase in Spain. Active fixation mechanisms predominate for leads but just 20% of leads are compatible with magnetic resonance imaging. The factors influencing the correct selection of pacing mode were age and, to a lesser extent, the type of atrioventricular block, and sex. Implementation of home monitoring of pacemakers remains low. Copyright © 2014 Sociedad Española de Cardiología. Published by Elsevier Espana. All rights reserved.

  3. Bipolar disorder: an update | Outhoff | South African Family Practice

    African Journals Online (AJOL)

    Bipolar disorder, characterised by alternating discrete episodes of (hypo)mania and depression, provides unique diagnostic and treatment challenges. Updated diagnostic (DSM-5) and current pharmacological treatment recommendations are briefly reviewed here. Keywords: bipolar disorder; diagnosis; evidence-based ...

  4. What is Bipolar Disorder?

    Science.gov (United States)

    ... affect friends and family? For More Information Share Bipolar Disorder Download PDF Download ePub Order a free hardcopy ... brochure will give you more information. What is bipolar disorder? Bipolar disorder is a serious brain illness. It ...

  5. Ventricular perforation by pacemaker lead repaired with two hemostatic devices.

    Science.gov (United States)

    Prestipino, Filippo; Nenna, Antonio; Casacalenda, Adele; Chello, Massimo

    2014-01-01

    Cardiac perforation is a rare, but potentially serious, complication of pacemaker implantation that may develop days or weeks after implantation. In the current case, 92-year-old man underwent permanent pacemaker implantation, but he presented 3 weeks later with severe symptoms. Computed tomography showed protrusion of the tip of the ventricular electrode through the right ventricle and into the chest wall. During an urgent surgical intervention, the lead was disconnected and extracted. A sealing hemostatic device and an hemostatic patch were applied to repair the ventricle; the procedure was uneventfull. This case demonstrates how the correct diagnosis of ventricular perforation is crucial, and should be followed immediately by surgical planning. The hemostatic patch is a valuable alternative to sutures in patients with thin and fragile ventricular wall, unable to undergo stitching. Copyright © 2014 The Authors. Published by Elsevier Ltd.. All rights reserved.

  6. Transtorno bipolar

    Directory of Open Access Journals (Sweden)

    Alda Martin

    1999-01-01

    Full Text Available Os resultados de estudos de famílias sugerem que o transtorno bipolar tenha uma base genética. Essa hipótese foi reforçada em estudos de adoção e de gêmeos. A herança do transtorno bipolar é complexa, envolve vários genes, além de apresentar heterogeneidade e interação entre fatores genéticos e não-genéticos. Achados, que já foram replicados, já implicaram os cromossomos 4, 12, 18 e 21, entre outros, na busca por genes de suscetibilidade. Os resultados mais promissores foram obtidos através de estudos de ligação. Por outro lado, os estudos de associação geraram dados interessantes, mas ainda vagos. Os estudos de populações de pacientes homogêneos e a melhor definição do fenótipo deverão contribuir para avanços futuros. A identificação dos genes relacionados ao transtorno bipolar irá permitir o melhor entendimento e tratamento dessa doença.

  7. Minimally Invasive Epicardial Pacemaker Implantation in Neonates with Congenital Heart Block.

    Science.gov (United States)

    Costa, Roberto; Silva, Katia Regina da; Martinelli Filho, Martino; Carrillo, Roger

    2017-10-01

    Few studies have characterized the surgical outcomes following epicardial pacemaker implantation in neonates with congenital complete atrioventricular block (CCAVB). This study sought to assess the long-term outcomes of a minimally invasive epicardial approach using a subxiphoid access for pacemaker implantation in neonates. Between July 2002 and February 2015, 16 consecutive neonates underwent epicardial pacemaker implantation due to CCAVB. Among these, 12 (75.0%) had congenital heart defects associated with CCAVB. The patients had a mean age of 4.7 ± 5.3 days and nine (56.3%) were female. Bipolar steroid-eluting epicardial leads were implanted in all patients through a minimally invasive subxiphoid approach and fixed on the diaphragmatic ventricular surface. The pulse generator was placed in an epigastric submuscular position. All procedures were successful, with no perioperative complications or early deaths. Mean operating time was 90.2 ± 16.8 minutes. None of the patients displayed pacing or sensing dysfunction, and all parameters remained stable throughout the follow-up period of 4.1 ± 3.9 years. Three children underwent pulse generator replacement due to normal battery depletion at 4.0, 7.2, and 9.0 years of age without the need of ventricular lead replacement. There were two deaths at 12 and 325 days after pacemaker implantation due to bleeding from thrombolytic use and progressive refractory heart failure, respectively. Epicardial pacemaker implantation through a subxiphoid approach in neonates with CCAVB is technically feasible and associated with excellent surgical outcomes and pacing lead longevity.

  8. Management of radiation oncology patients with a pacemaker or ICD : A new comprehensive practical guideline in The Netherlands

    NARCIS (Netherlands)

    Hurkmans, Coen W.; Knegjens, Joost L.; Oei, Bing S.; Maas, Ad J. J.; Uiterwaal, G. J.; van der Borden, Arnoud J.; Ploegmakers, Marleen M. J.; van Erven, Lieselot

    2012-01-01

    Current clinical guidelines for the management of radiotherapy patients having either a pacemaker or implantable cardioverter defibrillator (both CIEDs: Cardiac Implantable Electronic Devices) do not cover modern radiotherapy techniques and do not take the patient's perspective into account.

  9. Pacemaker

    Science.gov (United States)

    ... Heart and Vascular Diseases Precision Medicine Activities Obesity, Nutrition, and Physical Activity Population and Epidemiology Studies Women’s Health All Science A-Z Grants and Training Grants and Training ...

  10. Prefronto–cerebellar transcranial direct current stimulation improves visuospatial memory, executive functions, and neurological soft signs in patients with euthymic bipolar disorder

    Directory of Open Access Journals (Sweden)

    Minichino A

    2015-08-01

    Full Text Available Amedeo Minichino, Francesco Saverio Bersani, Laura Bernabei, Francesco Spagnoli, Lucilla Vergnani, Alessandra Corrado, Ines Taddei, Massimo Biondi, Roberto Delle Chiaie Department of Neurology and Psychiatry, Sapienza University of Rome, Rome, Italy Objective: The aim of the study was to improve neuropsychological functioning of euthymic patients with bipolar disorder (BD using transcranial direct current stimulation (tDCS applied to cerebellar and prefrontal cortices.Methods: Twenty-five BD outpatients underwent prefrontal (anodal and cerebellar (cathodal tDCS for 3 consecutive weeks. All participants were assessed through the Rey Complex Figure Test delay and copy and the Neurological Examination Scale at baseline and after therapy with tDCS.Results: After tDCS treatment, patients showed significant improvements in visuospatial memory tasks. Patients with worse baseline cognitive performances also showed a significant improvement in executive functioning tasks. Neurological Examination Scale total score and motor coordination subscale significantly improved.Conclusion: Prefrontal-excitatory and cerebellar-inhibitory stimulations in euthymic BD patients may lead to better neurocognitive performances. This improvement could result from the modulation of prefronto–thalamic–cerebellar circuit activity pattern, which can be disrupted in BD. Keywords: cerebellum, dorsolateral prefrontal cortex, neuropsychology, cognition 

  11. Interference with cardiac pacemakers by magnetic resonance imaging: are there irreversible changes at 0.5 Tesla?

    Science.gov (United States)

    Vahlhaus, C; Sommer, T; Lewalter, T; Schimpf, R; Schumacher, B; Jung, W; Lüderitz, B

    2001-04-01

    The safety and feasibility of magnetic resonance imaging (MRI) in patients with cardiac pacemakers is an issue of gaining significance. The effect of MRI on patients' pacemaker systems has only been analyzed retrospectively in some case reports. Therefore, this study prospectively investigated if MRI causes irreversible changes in patients' pacemaker systems. The effect of MRI at 0.5 Tesla on sensing and stimulation thresholds, lead impedance and battery voltage, current, and impedance was estimated during 34 MRI examinations in 32 patients with implanted pacemakers. After measurements at baseline and with documentation of intrinsic rhythm and modification of the pacing mode, patients underwent MRI. The rest of the function time of the pacemaker was calculated. Measurements were again performed after 99.5 +/- 29.6 minutes (mean +/- SD), immediately after MRI examination, and 3 months later. Lead impedance and sensing and stimulation thresholds did not change after MRI. Battery voltage decreased immediately after MRI and recovered 3 months later. Battery current and impedance tended to increase. The calculated rest of function time did not change immediately after MRI. MRI affected neither pacemaker programmed data, nor the ability to interrogate, program, or use telemetry. Surprisingly, in the gantry of the scanner, temporary deactivation of the reed switch occurred in 12 of 32 patients when positioned in the center of the magnetic field. Missing activation of the reed switch through the static magnetic field at 0.5 Tesla is not unusual. MRI at 0.5 Tesla does not cause irreversible changes in patients' pacemaker systems.

  12. Quality assessment of pacemaker implantations in Denmark

    DEFF Research Database (Denmark)

    Møller, M; Arnsbo, P; Asklund, Mogens

    2002-01-01

    AIMS: Quality assessment of therapeutic procedures is essential to insure a cost-effective health care system. Pacemaker implantation is a common procedure with more than 500,000 implantations world-wide per year, but the general complication rate is not well described. We studied procedure related...... complications for all implantations performed in an entire nation over a 3-year period. METHODS AND RESULTS: A prospective study of complications related to 99% of the 5648 primary pacemaker implantations performed in the 12 Danish pacemaker centres in 1997-1999 was carried out. Overall 76% of the patients...... received a physiological pacemaker system and 91% received the optimal pacing mode according to international guidelines. Perioperative complications requiring reoperation were: haematoma 0.3%, atrial lead related 1.9%, ventricular lead related 1.7%. Late complications requiring reoperation were: infection...

  13. Bipolar Disorder and Obsessive Compulsive Disorder Comorbidity

    Directory of Open Access Journals (Sweden)

    Necla Keskin

    2014-08-01

    Full Text Available The comorbidity of bipolar disorder and anxiety disorders is a well known concept. Obsessive-compulsive disorder is the most commonly seen comorbid anxiety disorder in bipolar patients. Some genetic variants, neurotransmitters especially serotonergic systems and second-messenger systems are thought to be responsible for its etiology. Bipolar disorder alters the clinical aspects of obsessive compulsive disorder and is associated with poorer outcome. The determination of comorbidity between bipolar disorder and obsessive compulsive disorder is quite important for appropriate clinical management and treatment. [Psikiyatride Guncel Yaklasimlar - Current Approaches in Psychiatry 2014; 6(4.000: 429-437

  14. Amorphous silicon germanium carbide photo sensitive bipolar junction transistor with a base-contact and a continuous tunable high current gain

    Energy Technology Data Exchange (ETDEWEB)

    Bablich, A., E-mail: andreas.bablich@uni-siegen.de [Department of Electrical and Computer Engineering, Institute for Microsystem Technologies, University of Siegen, Hoelderlinstrasse 3, 57076 Siegen (Germany); Merfort, C., E-mail: merfort@imt.e-technik.uni-siegen.de [Department of Electrical and Computer Engineering, Institute for Microsystem Technologies, University of Siegen, Hoelderlinstrasse 3, 57076 Siegen (Germany); Eliasz, J., E-mail: jacek.eliasz@student.uni-siegen.de [Department of Electrical and Computer Engineering, Institute for Microsystem Technologies, University of Siegen, Hoelderlinstrasse 3, 57076 Siegen (Germany); Schäfer-Eberwein, H., E-mail: heiko.schaefer@uni-siegen.de [Department of Electrical and Computer Engineering, Institute of High Frequency and Quantum Electronics, University of Siegen, Hoelderlinstrasse 3, 57076 Siegen (Germany); Haring-Bolivar, P., E-mail: peter.haring@uni-siegen.de [Department of Electrical and Computer Engineering, Institute of High Frequency and Quantum Electronics, University of Siegen, Hoelderlinstrasse 3, 57076 Siegen (Germany); Boehm, M., E-mail: markus.boehm@uni-siegen.de [Department of Electrical and Computer Engineering, Institute for Microsystem Technologies, University of Siegen, Hoelderlinstrasse 3, 57076 Siegen (Germany)

    2014-05-02

    In this paper, the design, fabrication and characterization of an amorphous silicon germanium carbide (a-SiGeC:H) photo sensitive bipolar junction transistor (PS-BJT) with three terminals are presented. Whereas the current gain of similar transistor devices presented in the past (Wu et al., 1984; Hwang et al., 1993; Nascetti and Caputo, 2002; Chang et al., 1985a,b; Wu et al, 1985; Hong et al., 1990) can only be controlled with photo induced charge generation, the n–i–δp–i–n structure developed features a contacted base to provide the opportunity to adjust the current gain optically and electrically, too. Electron microscope-, current-/voltage- and spectral measurements were performed to study the PS-BJT behavior and calculate the electrical and optical current gain. The spectral response maximum of the base–collector diode has a value of 170 mA/W applying a base–collector voltage of − 1 V and is located at 620 nm. The base–emitter diode reaches a sensitivity of 25.7 mA/W at 530 nm with a base-emitter voltage of − 3 V. The good a-Si:H transport properties are validated in a μτ-product of 4.6 × 10{sup −6} cm{sup 2} V s, which is sufficient to reach a continuous base- and photo-tunable current gain of up to − 126 at a base current of I{sub B} = + 10 nA and a collector–emitter voltage of V{sub CE} = − 3 V. The transistor obtains a maximum collector current of − 65.5 μA (V{sub CE} = − 3 V) and + 56.2 μA (V{sub CE} = + 3 V) at 10,000 lx 5300 K white-light illumination. At 3300 lx, the electrical current gain reaches a value of + 100 (V{sub CE} = + 2 V) at I{sub B} = 10 nA. With a negative base current of I{sub B} = − 10 nA the electrical gain can be adjusted between 87 (V{sub CE} = + 2 V) and − 106 (V{sub CE} = -3 V), respectively. When no base charge is applied, the transistor is “off” for V{sub CE} > − 3 V. Reducing the base current increases the electrical current gain. Operating with a voltage V{sub CE} of just ± 2 V

  15. Modeling suicide in bipolar disorders.

    Science.gov (United States)

    Malhi, Gin S; Outhred, Tim; Das, Pritha; Morris, Grace; Hamilton, Amber; Mannie, Zola

    2018-02-19

    Suicide is a multicausal human behavior, with devastating and immensely distressing consequences. Its prevalence is estimated to be 20-30 times greater in patients with bipolar disorders than in the general population. The burden of suicide and its high prevalence in bipolar disorders make it imperative that our current understanding be improved to facilitate prediction of suicide and its prevention. In this review, we provide a new perspective on the process of suicide in bipolar disorder, in the form of a novel integrated model that is derived from extant knowledge and recent evidence. A literature search of articles on suicide in bipolar disorder was conducted in recognized databases such as Scopus, PubMed, and PsycINFO using the keywords "suicide", "suicide in bipolar disorders", "suicide process", "suicide risk", "neurobiology of suicide" and "suicide models". Bibliographies of identified articles were further scrutinized for papers and book chapters of relevance. Risk factors for suicide in bipolar disorders are well described, and provide a basis for a framework of epigenetic mechanisms, moderated by neurobiological substrates, neurocognitive functioning, and social inferences within the environment. Relevant models and theories include the diathesis-stress model, the bipolar model of suicide and the ideation-to-action models, the interpersonal theory of suicide, the integrated motivational-volitional model, and the three-step theory. Together, these models provide a basis for the generation of an integrated model that illuminates the suicidal process, from ideation to action. Suicide is complex, and it is evident that a multidimensional and integrated approach is required to reduce its prevalence. The proposed model exposes and provides access to components of the suicide process that are potentially measurable and may serve as novel and specific therapeutic targets for interventions in the context of bipolar disorder. Thus, this model is useful not only

  16. Bipolar disorder: an overview

    African Journals Online (AJOL)

    which is the reason that up to 69% of patients with BD are misdiagnosed.1 Bipolar ... Cyclothymic disorder. • Substance/medication induced bipolar and related disorder. • Bipolar and related disorder due to another medical condition ... patients. Keywords: bipolar disorder, mania, depression, pharmacological management.

  17. Pacemaker diagnostics in atrial fibrillation: limited usefulness for therapy initiation in a pacemaker practice.

    Science.gov (United States)

    Yedlapati, Neeraja; Fisher, John D

    2014-09-01

    We aimed to determine the practical value of pacemaker diagnostics for atrial fibrillation (AF) in an unselected general pacemaker practice, specifically workflow and initiation of anticoagulation or antiarrhythmic drug (AAD) therapy. We prospectively followed consecutive pacemaker interrogations over a period of 1 year to identify patients with AF (burden from 1% to 99%). We contacted referring physicians with AF details, and then determined whether the information resulted in therapeutic changes. Of the 1,100 pacemakers interrogated, 728 were dual chamber (DDDs) with AF diagnostic capability. AF was recorded in 73 (10%) but seven had limited information, leaving 66 patients; of these, 42 (63%) patients were already anticoagulated and in five (7%) patients, anticoagulation had been stopped because of complications. Initial diagnosis of AF was made by the pacemaker in 17 patients (26% of 66; 2% of 728); four (6% of 66) patients were newly initiated on anticoagulation. Of the 66 patients, 17 patients were already on AADs; 49 (74%) had satisfactory rate control or had other issues; only two (3% of 66; 0.3% of 728) received new AADs. Of 728 patients with DDD pacemakers, only 17 were newly discovered to have AF, and six (0.8%) had changes in medications based on the pacemaker data. Adding pacemaker-derived data to existing clinical information had little therapeutic impact, due to a combination of cumbersome workflow, and because AF was usually known to practitioners. Developments in automated monitoring systems may provide more accessible and therapeutically useful information. ©2014 Wiley Periodicals, Inc.

  18. Voltage regulator for battery power source. [using a bipolar transistor

    Science.gov (United States)

    Black, J. M. (Inventor)

    1979-01-01

    A bipolar transistor in series with the battery as the control element also in series with a zener diode and a resistor is used to maintain a predetermined voltage until the battery voltage decays to very nearly the predetermined voltage. A field effect transistor between the base of the bipolar transistor and a junction between the zener diode and resistor regulates base current of the bipolar transistor, thereby regulating the conductivity of the bipolar transistor for control of the output voltage.

  19. Integrated neurobiology of bipolar disorder

    Directory of Open Access Journals (Sweden)

    Vladimir eMaletic

    2014-08-01

    Full Text Available From a neurobiological perspective there is no such thing as bipolar disorder. Rather, it is almost certainly the case that many somewhat similar, but subtly different, pathological conditions produce a disease state that we currently diagnose as bipolarity. This heterogeneity—reflected in the lack of synergy between our current diagnostic schema and our rapidly advancing scientific understanding of the condition—limits attempts to articulate an integrated perspective on bipolar disorder. However, despite these challenges, scientific findings in recent years are beginning to offer a provisional unified field theory of the disease. This theory sees bipolar disorder as a suite of related neurodevelopmental conditions with interconnected functional abnormalities that often appear early in life and worsen over time. In addition to accelerated loss of volume in brain areas known to be essential for mood regulation and cognitive function, consistent findings have emerged at a cellular level, providing evidence that bipolar disorder is reliably associated with dysregulation of glial-neuronal interactions. Among these glial elements are microglia—the brain’s primary immune elements, which appear to be overactive in the context of bipolarity. Multiple studies now indicate that inflammation is also increased in the periphery of the body in both the depressive and manic phases of the illness, with at least some return to normality in the euthymic state. These findings are consistent with changes in the HPA axis, which are known to drive inflammatory activation. In summary, the very fact that no single gene, pathway or brain abnormality is likely to ever account for the condition is itself an extremely important first step in better articulating an integrated perspective on both its ontological status and pathogenesis. Whether this perspective will translate into the discovery of innumerable more homogeneous forms of bipolarity is one of the great

  20. Aggregatibacter aphrophilus pacemaker endocarditis: a case report.

    Science.gov (United States)

    Patel, Sahil R; Patel, Nishi H; Borah, Amit; Saltzman, Heath

    2014-12-08

    Aggregatibacter bacteria are a rare cause of endocarditis in adults. They are part of a group of organisms known as HACEK--Haemophilus, Aggregatibacter, Cardiobacter, Eikenella, and Kingella. Among these organisms, several Haemophilus species have been reclassified under the genus Aggregatibacter. Very few cases of Aggregatibacter endocarditis in patients with pacemaker devices have been reported. We present here what we believe to be the first case of Aggregatibacter aphrophilus pacemaker endocarditis. A 62-year-old African American male with a medical history significant for dual-chamber pacemaker placement in 1996 for complete heart block with subsequent lead manipulation in 2007, presented to his primary care doctor with fever, chills, night sweats, fatigue, and ten-pound weight loss over a four-month period. Physical examination revealed a new murmur and jugular venous distension which prompted initiation of antibiotics for suspicion of endocarditis. Both sets of initial blood cultures were positive for A. aphrophilus. Transesophageal echocardiogram revealed vegetations on the tricuspid valve and the right ventricular pacemaker lead (Figure 1). This case highlights the importance of identifying rare causes of endocarditis and recognizing that treatment may not differ from the standard treatment for typical presentations. The patient received intravenous ceftriaxone for his endocarditis for a total of six weeks. Upon device removal, temporary jugular venous pacing wires were placed. After two weeks of antibiotic treatment and no clinical deterioration, a new permanent pacemaker was placed and the patient was discharged home. This is the first case of A. aphrophilus endocarditis in a patient with a permanent pacemaker. Our patient had no obvious risk factors other than poor dentition and a history of repeated pacemaker lead manipulation. This suggests that valvulopathies secondary to repeated lead manipulation can be clinically significant factors in morbidity

  1. Toward a complex system understanding of bipolar disorder: A chaotic model of abnormal circadian activity rhythms in euthymic bipolar disorder.

    Science.gov (United States)

    Hadaeghi, Fatemeh; Hashemi Golpayegani, Mohammad Reza; Jafari, Sajad; Murray, Greg

    2016-08-01

    In the absence of a comprehensive neural model to explain the underlying mechanisms of disturbed circadian function in bipolar disorder, mathematical modeling is a helpful tool. Here, circadian activity as a response to exogenous daily cycles is proposed to be the product of interactions between neuronal networks in cortical (cognitive processing) and subcortical (pacemaker) areas of the brain. To investigate the dynamical aspects of the link between disturbed circadian activity rhythms and abnormalities of neurotransmitter functioning in frontal areas of the brain, we developed a novel mathematical model of a chaotic system which represents fluctuations in circadian activity in bipolar disorder as changes in the model's parameters. A novel map-based chaotic system was developed to capture disturbances in circadian activity across the two extreme mood states of bipolar disorder. The model uses chaos theory to characterize interplay between neurotransmitter functions and rhythm generation; it aims to illuminate key activity phenomenology in bipolar disorder, including prolonged sleep intervals, decreased total activity and attenuated amplitude of the diurnal activity rhythm. To test our new cortical-circadian mathematical model of bipolar disorder, we utilized previously collected locomotor activity data recorded from normal subjects and bipolar patients by wrist-worn actigraphs. All control parameters in the proposed model have an important role in replicating the different aspects of circadian activity rhythm generation in the brain. The model can successfully replicate deviations in sleep/wake time intervals corresponding to manic and depressive episodes of bipolar disorder, in which one of the excitatory or inhibitory pathways is abnormally dominant. Although neuroimaging research has strongly implicated a reciprocal interaction between cortical and subcortical regions as pathogenic in bipolar disorder, this is the first model to mathematically represent this

  2. Bipolar Items

    Directory of Open Access Journals (Sweden)

    Nishiguchi Sumiyo

    2016-12-01

    Full Text Available This article asserts that the Japanese wide-scope mo ‘even’ in simple sentences are bipolar items (BPIs antilicensed or forbidden by negation and licensed in a non-monotonic (NM environment. BPIs share the features of negative polarity items (NPIs as well as positive polarity items (PPIs. The Dutch ooit ‘ever’, the Serbo-Croatian i-series ‘and/even’, and the Hungarian is-series ‘and/even’ are antilicensed by clausemate negation and licensed by extraclausal negation (van der Wouden, 1997; Progovac, 1994; Szabolcsi, 2002 or non-monotonic negative (and positive, for Serbo-Croatian emotive predicates. Adding an NPI rescues BPIs in uncomfortable clausemate negation.

  3. Quetiapine monotherapy for bipolar depression

    Directory of Open Access Journals (Sweden)

    Michael E Thase

    2008-03-01

    Full Text Available Michael E ThaseDepartments of Psychiatry, University of Pennsylvania School of Medicine, Philadelphia, PA, USA; the Philadelphia Veterans Affairs Medical Center, Philadelphia, PA, USA; and the University of Pittsburgh Medical Center, Pittsburgh, PA, USAAbstract: Bipolar depression is more common, disabling, and difficult-to-treat than the manic and hypomanic phases that define bipolar disorder. Unlike the treatment of so-called “unipolar” depressions, antidepressants generally are not indicated as monotherapies for bipolar depressions and recent studies suggest that - even when used in combination with traditional mood stabilizers – antidepressants may have questionable value for bipolar depression. The current practice is that mood stabilizers are initiated first as monotherapies; however, the antidepressant efficacy of lithium and valproate is modest at best. Within this context the role of atypical antipsychotics is being evaluated. The combination of olanzapine and the antidepressant fluoxetine was the first treatment to receive regulatory approval in the US specifically for bipolar I depression. Quetiapine was the second medication to be approved for this indication, largely as the result of two pivotal trials known by the acronyms of BOLDER (BipOLar DEpRession I and II. Both studies demonstrated that two doses of quetiapine (300 mg and 600 mg given once daily at bedtime were significantly more effective than placebo, with no increased risk of patients switching into mania. Pooling the two studies, quetiapine was effective for both bipolar I and bipolar II depressions and for patients with (and without a history of rapid cycling. The two doses were comparably effective in both studies. Although the efficacy of quetiapine monotherapy has been established, much additional research is necessary. Further studies are needed to more fully investigate dose-response relationships and comparing quetiapine monotherapy to other mood stabilizers

  4. Runaway pacemaker: a still existing complication and therapeutic guidelines

    DEFF Research Database (Denmark)

    Mickley, H; Andersen, C; Nielsen, L H

    1989-01-01

    Runaway pacemaker is a rare, but still existing potential lethal complication in permanent pacemakers. Within 4 1/2 years, we saw two cases of runaway pacemaker in patients with multiprogrammable, VVI pacemakers (Siemens-Elema, Model 668). In both cases a pacemaker-induced ventricular tachycardia...... (rate 240-260 beats/min) was documented. One patient died. Runaway pacemakers must be exchanged as soon as possible. Until this can be accomplished, different emergency maneuvers should be tried. As documented in the cases presented, placing a magnet over the pacemaker may result in a lower, more...... pacemaker may be connected to the permanent pacing lead. Thereafter, the lead can be safely cut. As an alternative, a temporary transvenous pacing lead may be established prior to disconnecting the permanent pacing lead....

  5. Drugs and pacemakers for vasovagal, carotid sinus and situational syncope

    NARCIS (Netherlands)

    Romme, Jacobus J. C. M.; Reitsma, Johannes B.; Black, Catherine N.; Colman, Nancy; Scholten, Rob J. P. M.; Wieling, Wouter; van Dijk, Nynke

    2011-01-01

    Background Neurally mediated reflex syncope is the most common cause of transient loss of consciousness. In patients not responding to nonpharmacological treatment, pharmacological or pacemaker treatment might be considered. Objectives To examine the effects of pharmacological therapy and pacemaker

  6. Pacemaker patients’ perspective and experiences in a pacemaker outpatient clinic in relation to test intervals of the pacemaker

    DEFF Research Database (Denmark)

    Lauberg, Astrid; Hansen, Tina; Pedersen, Trine Pernille Dahl

    an evident decline in quality of life regarding psychological and social aspects 6 month after the implantation in terms of cognitive function, work ability, and sexual activity. Mlynarski et al (2009) have found correlations between pacemaker implantation and anxiety and depression. Aim The aim...... the pacemaker and psychological reactions. Patients with pacemakers older than 3 months lacked communication with fellowmen. Conclusion The patients express receiving competent and professional treatment when visiting the outpatient clinic, there seems to be a discrepancy between the long test intervals...... and the critical period in which anxiety and depression may occur. Minor problems and questions may grow into fatal conditions if the patients are not offered an opportunity to discuss this with experts. Patients are not informed that it is possible to discuss problems that imply psychological topics and they do...

  7. Setups for in vitro assessment of RFID interference on pacemakers

    International Nuclear Information System (INIS)

    Mattei, E; Censi, F; Delogu, A; Ferrara, A; Calcagnini, G

    2013-01-01

    The aim of this study is to propose setups for in vitro assessment of RFID (radiofrequency identification) interference on pacemakers (PM). The voltage induced at the input stage of the PM by low-frequency (LF) and high-frequency (HF) RFID transmitters has been used to quantify the amount of the interference. A commercial PM was modified in order to measure the voltage at its input stage when exposed to a sinusoidal signal at 125 kHz and 13.56 MHz. At both frequencies, two antennas with different dimensions (diameter = 10 cm and 30 cm, respectively) were used to generate the interfering field, and the induced voltage was measured between the lead tip and the PM case (unipolar voltage), and between the tip and ring electrodes (bipolar voltage). The typical lead configurations adopted in similar studies or proposed by international standards, as well as lead paths closer to actual physiological implants were tested. At 125 kHz, the worst-case condition differs for the two antennas: the 10 cm antenna induced the highest voltage in the two-loop spiral configuration, whereas the 30 cm antenna in the 225 cm 2 loop configuration. At 13.56 MHz, the highest voltage was observed for both the antennas in the 225 cm 2 loop configuration. Bipolar voltages were found to be lower than the unipolar voltages induced in the same configurations, this difference being not as high as one could expect from theoretical considerations. The worst-case scenario, in terms of the induced voltage at the PM input stage, has been identified both for LF and HF readers, and for two sizes of transmitting antennas. These findings may provide the basis for the definition of a standard implant configuration and a lead path to test the EMI effects of LF and HF RFID transmitters on active implantable devices. (paper)

  8. Spanish Pacemaker Registry. Twelfth Official Report of the Spanish Society of Cardiology Working Group on Cardiac Pacing (2014).

    Science.gov (United States)

    Cano Pérez, Óscar; Pombo Jiménez, Marta; Coma Samartín, Raúl

    2015-12-01

    This report describes the results of the analysis of pacemaker implant and replacement data submitted to the Spanish Pacemaker Registry in 2014, with special reference to pacing mode selection. The report is based on the processing of information provided by the European Pacemaker Patient Identification Card. Information was received from 117 hospitals, with a total of 12 358 cards, representing 34% of estimated activity. Use of conventional generators and resynchronization devices was 784 and 64.4 units per million population, respectively. The mean age of patients receiving an implant was 77.3 years. Men received 59% of implants and 56.4% of replacements. Most patients receiving generator implants and replacements were in the age range 80 to 89 years. Most endocardial leads used were bipolar, and 84.2% had an active fixation system. Pacing was in VVI/R mode despite being in sinus rhythm in 24.7% of patients with sick sinus syndrome and 24% of those with atrioventricular block. The use of pacemaker generators and resynchronization devices per million population continued to increase. Most implanted leads had active fixation and approximately 20% had magnetic resonance imaging protection. Age and sex directly influenced pacing mode selection, which could have been improved in more than 20% of cases. Copyright © 2015 Sociedad Española de Cardiología. Published by Elsevier España, S.L.U. All rights reserved.

  9. The pacemaker-twiddler's syndrome: an infrequent cause of pacemaker failure.

    Science.gov (United States)

    Salahuddin, Mohammad; Cader, Fathima Aaysha; Nasrin, Sahela; Chowdhury, Mashhud Zia

    2016-01-20

    The pacemaker-twiddler's syndrome is an uncommon cause of pacemaker malfunction. It occurs due to unintentional or deliberate manipulation of the pacemaker pulse generator within its skin pocket by the patient. This causes coiling of the lead and its dislodgement, resulting in failure of ventricular pacing. More commonly reported among elderly females with impaired cognition, the phenomenon usually occurs in the first year following pacemaker implantation. Treatment involves repositioning of the dislodged leads and suture fixation of the lead and pulse generator within its pocket. An 87 year old Bangladeshi lady who underwent a single chamber ventricular pacemaker (VVI mode: i.e. ventricle paced, ventricle sensed, inhibitory mode) implantation with the indication of complete heart block, and presented to us again 7 weeks later, with syncopal attacks. She admitted to repeatedly manipulating the pacemaker generator in her left pectoral region. Physical examination revealed a heart rate of 42 beats/minute, blood pressure 140/80 mmHg and bilateral crackles on lung auscultation. She had no cognitive deficit. An immediate electrocardiogram showed complete heart block with pacemaker spikes and failure to capture. Chest X-ray showed coiled and retracted right ventricular lead and rotated pulse generator. An emergent temporary pace maker was set at a rate of 60 beats per minute. Subsequently, she underwent successful lead repositioning with strong counselling to avoid further twiddling. Twiddler's syndrome should be considered as a cause of pacemaker failure in elderly patients presenting with bradyarrythmias following pacemaker implantation. Chest X-ray and electrocardiograms are simple and easily-available first line investigations for its diagnosis. Lead repositioning is required, however proper patient education and counselling against further manipulation is paramount to long-term management.

  10. 21 CFR 870.3710 - Pacemaker repair or replacement material.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Pacemaker repair or replacement material. 870.3710... (CONTINUED) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Prosthetic Devices § 870.3710 Pacemaker repair or replacement material. (a) Identification. A pacemaker repair or replacement material is an...

  11. 21 CFR 870.3730 - Pacemaker service tools.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Pacemaker service tools. 870.3730 Section 870.3730...) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Prosthetic Devices § 870.3730 Pacemaker service tools. (a) Identification. Pacemaker service tools are devices such as screwdrivers and Allen wrenches...

  12. 21 CFR 870.5550 - External transcutaneous cardiac pacemaker (noninvasive).

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false External transcutaneous cardiac pacemaker... § 870.5550 External transcutaneous cardiac pacemaker (noninvasive). (a) Identification. An external transcutaneous cardiac pacemaker (noninvasive) is a device used to supply a periodic electrical pulse intended to...

  13. 21 CFR 870.3720 - Pacemaker electrode function tester.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Pacemaker electrode function tester. 870.3720... (CONTINUED) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Prosthetic Devices § 870.3720 Pacemaker electrode function tester. (a) Identification. A pacemaker electrode function tester is a device which is...

  14. 21 CFR 870.3650 - Pacemaker polymeric mesh bag.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Pacemaker polymeric mesh bag. 870.3650 Section 870...) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Prosthetic Devices § 870.3650 Pacemaker polymeric mesh bag. (a) Identification. A pacemaker polymeric mesh bag is an implanted device used to hold a...

  15. 21 CFR 870.3630 - Pacemaker generator function analyzer.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Pacemaker generator function analyzer. 870.3630... (CONTINUED) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Prosthetic Devices § 870.3630 Pacemaker generator function analyzer. (a) Identification. A pacemaker generator function analyzer is a device that is...

  16. 21 CFR 870.3610 - Implantable pacemaker pulse generator.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Implantable pacemaker pulse generator. 870.3610 Section 870.3610 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES... pacemaker pulse generator. (a) Identification. An implantable pacemaker pulse generator is a device that has...

  17. 21 CFR 870.1750 - External programmable pacemaker pulse generator.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false External programmable pacemaker pulse generator... External programmable pacemaker pulse generator. (a) Identification. An external programmable pacemaker pulse generators is a device that can be programmed to produce one or more pulses at preselected...

  18. 21 CFR 870.3600 - External pacemaker pulse generator.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false External pacemaker pulse generator. 870.3600 Section 870.3600 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES... pacemaker pulse generator. (a) Identification. An external pacemaker pulse generator is a device that has a...

  19. 21 CFR 870.3690 - Pacemaker test magnet.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Pacemaker test magnet. 870.3690 Section 870.3690...) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Prosthetic Devices § 870.3690 Pacemaker test magnet. (a) Identification. A pacemaker test magnet is a device used to test an inhibited or triggered type...

  20. Analysis of a five year experience of permanent pacemaker ...

    African Journals Online (AJOL)

    Introduction: Permanent pacemaker implantation is available in Nigeria. There is however no national registry or framework for pacemaker data collection. A pacemaker database has been developed in our institution and the results are analyzed in this study. Methods: The study period was between January 2008 and ...

  1. Reflex sympathetic dystrophy following pacemaker insertion.

    Science.gov (United States)

    Londhey, Vikram A; Singh, Nishant; Kini, Seema

    2011-09-01

    A 55 year old male presented with pain and swelling over dorsum of right hand and small joints, and loss of sweating over right hand since two months. He was a known case of mitral valve prolapse (MVP) with mitral regurgitation and complete heart block for which pacemaker was implanted 1 year back. Bilateral wrist X-ray was suggestive of pronounced demineralization (osteopenia) in the right hand. He was thus diagnosed to have reflex sympathetic dystrophy syndrome (RSDS) considered to be induced by pacemaker insertion. After treatment with amitryptiline and indomethacin his symptoms dramatically improved.

  2. Nuclear-powered pacemaker fuel cladding study

    International Nuclear Information System (INIS)

    Shoup, R.L.

    1976-07-01

    The fabrication of fuel capsules with refractory metal and alloy clads used in nuclear-powered cardiac pacemakers precludes the expedient dissolution of the clad in inorganic acid solutions. An experiment to measure penetration rates of acids on commonly used fuel pellet clads indicated that it is not impossible, but that it would be very difficult to dissolve the multiple cladding. This work was performed because of a suggestion that a 238 PuO 2 -powered pacemaker could be transformed into a terrorism weapon

  3. Genetics of bipolar disorder

    Directory of Open Access Journals (Sweden)

    Kerner B

    2014-02-01

    Full Text Available Berit Kerner Semel Institute for Neuroscience and Human Behavior, University of California, Los Angeles, Los Angeles, CA, USA Abstract: Bipolar disorder is a common, complex genetic disorder, but the mode of transmission remains to be discovered. Many researchers assume that common genomic variants carry some risk for manifesting the disease. The research community has celebrated the first genome-wide significant associations between common single nucleotide polymorphisms (SNPs and bipolar disorder. Currently, attempts are under way to translate these findings into clinical practice, genetic counseling, and predictive testing. However, some experts remain cautious. After all, common variants explain only a very small percentage of the genetic risk, and functional consequences of the discovered SNPs are inconclusive. Furthermore, the associated SNPs are not disease specific, and the majority of individuals with a “risk” allele are healthy. On the other hand, population-based genome-wide studies in psychiatric disorders have rediscovered rare structural variants and mutations in genes, which were previously known to cause genetic syndromes and monogenic Mendelian disorders. In many Mendelian syndromes, psychiatric symptoms are prevalent. Although these conditions do not fit the classic description of any specific psychiatric disorder, they often show nonspecific psychiatric symptoms that cross diagnostic boundaries, including intellectual disability, behavioral abnormalities, mood disorders, anxiety disorders, attention deficit, impulse control deficit, and psychosis. Although testing for chromosomal disorders and monogenic Mendelian disorders is well established, testing for common variants is still controversial. The standard concept of genetic testing includes at least three broad criteria that need to be fulfilled before new genetic tests should be introduced: analytical validity, clinical validity, and clinical utility. These criteria are

  4. Types of Bipolar Disorder

    Science.gov (United States)

    ... many people have bipolar disorder along with another illness such as anxiety disorder, substance abuse, or an eating disorder. People with ... are sometimes misdiagnosed with schizophrenia. Anxiety and ADHD: ... such as bipolar disorder. Risk Factors Scientists are ...

  5. The influence of radiation therapy on cardiac pacemakers

    International Nuclear Information System (INIS)

    Coles, J.R.; Ciddor, G.S.

    1980-01-01

    The results of an investigation to determine the influence on pacemaking of ionizing radiation and electromagnetic radiation from a number of radiotherapy machines are reported. In vitro tests were carried out on unipolar cardiac pacemakers of the ventricular inhibited type. The pacemakers were largely unaffected by the environment of clinical radiotherapy machines. Ionizing radiation had no detrimental effect on the pacemakers and electromagnetic interference caused only temporary single-beat inhibition at most. With the betatron used, malfunction of the pacemakers regularly occurred whilst in their inhibited made of operation. The demand function became disabled allowing competitive asynchronous pulses to be produced

  6. Cardiac Pacemaker Insertion in the South-South Region of Nigeria ...

    African Journals Online (AJOL)

    TNHJOURNALPH

    MEMORIA. URT. L. TEACHING. SPECIALI. HOSPITAL. ST. HOSPITAL. (BMSH). The Challenges To Pacemaker Insertion. In South-South Nigeria. The challenges based on the current state are that medical tourism booms to the detriment of capacity and infrastructural development in the sub region. In addition many tertiary.

  7. Psychotic and Bipolar Disorders: Bipolar Disorder.

    Science.gov (United States)

    Holder, Sarah D

    2017-04-01

    Bipolar disorder is a severe chronic mental illness that affects a large number of individuals. This disorder is separated into two major types, bipolar I disorder, with mania and typically recurrent depression, and bipolar II disorder, with recurrent major depression and hypomania. Patients with bipolar disorder spend the majority of time experiencing depression, and this typically is the presenting symptom. Because outcomes are improved with earlier diagnosis and treatment, physicians should maintain a high index of suspicion for bipolar disorder. The most effective long-term treatments are lithium and valproic acid, although other drugs also are used. In addition to referral to a mental health subspecialist for initiation and management of drug treatment, patients with bipolar disorder should be provided with resources for psychotherapy. Several comorbidities commonly associated with bipolar disorder include other mental disorders, substance use disorders, migraine headaches, chronic pain, stroke, metabolic syndrome, and cardiovascular disease. Family physicians who care for patients with bipolar disorder should focus their efforts on prevention and management of comorbidities. These patients should be assessed continually for risk of suicide because they are at high risk and their suicide attempts tend to be successful. Written permission from the American Academy of Family Physicians is required for reproduction of this material in whole or in part in any form or medium.

  8. Pacemaker stimulus amplitude alteration without loss of capture: an unusual ECG finding in cardiac tamponade from pacemaker lead perforation.

    Science.gov (United States)

    Suksaranjit, P; Prasidthrathsint, K

    2014-01-01

    A variation in pacemaker stimulus amplitude can represent pacemaker system dysfunction from generator malfunction, lead insulation defect, lead fracture, or artefact of digital signal processing of the electrocardiography recorder. Pacemaker lead perforation into the pericardial space typically results in loss of capture which was not demonstrated in our patient. In summary, we report an unusual ECG finding of pacemaker stimulus amplitude alteration without loss of capture in the setting of cardiac tamponade from pacemaker lead perforation. Copyright © 2013 Australian and New Zealand Society of Cardiac and Thoracic Surgeons (ANZSCTS) and the Cardiac Society of Australia and New Zealand (CSANZ). Published by Elsevier B.V. All rights reserved.

  9. Pseudo SVT in the pacemaker patient.

    Science.gov (United States)

    Modi, Simon; Barker, Diane; Cooper, Robert; Patwala, Ash; Hall, Mark

    2012-07-01

    This is an interesting report of a supraventricular tachycardia in a paced patient with intermittent atrioventricular nodal block. Only electrophysiology testing revealed the correct diagnosis. Images explain how pacemaker timing cycles and refractory periods can confuse an otherwise straightforward diagnosis. ©2010, The Authors. Journal compilation ©2010 Wiley Periodicals, Inc.

  10. Quality assessment of pacemaker implantations in Denmark

    DEFF Research Database (Denmark)

    Møller, M; Arnsbo, P; Asklund, Mogens

    2002-01-01

    AIMS: Quality assessment of therapeutic procedures is essential to insure a cost-effective health care system. Pacemaker implantation is a common procedure with more than 500,000 implantations world-wide per year, but the general complication rate is not well described. We studied procedure relat...

  11. The Drosophila melanogaster circadian pacemaker circuit

    Indian Academy of Sciences (India)

    2008-12-07

    Dec 7, 2008 ... large variety of tissues in the fly such as the eye, brain, pro- boscis, antennae, wings, abdomen, Malpighian tubules and testes (Plautz et al. 1997; Giebultowicz 2001). Although cell-autonomous circadian function is attributed to several tissues in Drosophila, circadian pacemaker neurons located in the brain ...

  12. Keeping the Rhythm : Cardiac Pacemaker Cell Development

    NARCIS (Netherlands)

    Burkhard, Silja

    2017-01-01

    The heart is the first organ to form and function in the developing vertebrate embryo. Its proper morphogenesis and function is crucial for survival. Here we focus on the development and characterization of a highly specialized subset of cardiac cells, the pacemaker cells. In the mammalian heart,

  13. Nutrition and Bipolar Depression.

    Science.gov (United States)

    Beyer, John L; Payne, Martha E

    2016-03-01

    As with physical conditions, bipolar disorder is likely to be impacted by diet and nutrition. Patients with bipolar disorder have been noted to have relatively unhealthy diets, which may in part be the reason they also have an elevated risk of metabolic syndrome and obesity. An improvement in the quality of the diet should improve a bipolar patient's overall health risk profile, but it may also improve their psychiatric outcomes. New insights into biological dysfunctions that may be present in bipolar disorder have presented new theoretic frameworks for understanding the relationship between diet and bipolar disorder. Copyright © 2016 Elsevier Inc. All rights reserved.

  14. Measuring pacemaker dose: A clinical perspective

    Energy Technology Data Exchange (ETDEWEB)

    Studenski, Matthew T., E-mail: matthew.studenski@jeffersonhospital.org [Department of Radiation Oncology at the Jefferson Medical College and Kimmel Cancer Center, Thomas Jefferson University, Philadelphia, PA (United States); Xiao Ying; Harrison, Amy S. [Department of Radiation Oncology at the Jefferson Medical College and Kimmel Cancer Center, Thomas Jefferson University, Philadelphia, PA (United States)

    2012-07-01

    Recently in our clinic, we have seen an increased number of patients presenting with pacemakers and defibrillators. Precautions are taken to develop a treatment plan that minimizes the dose to the pacemaker because of the adverse effects of radiation on the electronics. Here we analyze different dosimeters to determine which is the most accurate in measuring pacemaker or defibrillator dose while at the same time not requiring a significant investment in time to maintain an efficient workflow in the clinic. The dosimeters analyzed here were ion chambers, diodes, metal-oxide-semiconductor field effect transistor (MOSFETs), and optically stimulated luminescence (OSL) dosimeters. A simple phantom was used to quantify the angular and energy dependence of each dosimeter. Next, 8 patients plans were delivered to a Rando phantom with all the dosimeters located where the pacemaker would be, and the measurements were compared with the predicted dose. A cone beam computed tomography (CBCT) image was obtained to determine the dosimeter response in the kilovoltage energy range. In terms of the angular and energy dependence of the dosimeters, the ion chamber and diode were the most stable. For the clinical cases, all the dosimeters match relatively well with the predicted dose, although the ideal dosimeter to use is case dependent. The dosimeters, especially the MOSFETS, tend to be less accurate for the plans, with many lateral beams. Because of their efficiency, we recommend using a MOSFET or a diode to measure the dose. If a discrepancy is observed between the measured and expected dose (especially when the pacemaker to field edge is <10 cm), we recommend analyzing the treatment plan to see whether there are many lateral beams. Follow-up with another dosimeter rather than repeating multiple times with the same type of dosimeter. All dosimeters should be placed after the CBCT has been acquired.

  15. Bipolar Treatment: Are Bipolar I and Bipolar II Treated Differently?

    Science.gov (United States)

    ... management strategies. In addition to medications and other types of treatment, successful management of your bipolar disorder includes living a healthy lifestyle, such as getting enough sleep, eating a healthy diet and being physically active. ...

  16. Sexuality and Sexual Dysfunctions in Bipolar Disorder

    Directory of Open Access Journals (Sweden)

    Zeynep Namli

    2016-12-01

    Full Text Available In the clinical course of bipolar disorder, there is a reduction in sexual will during depressive episodes and inappopriate sexual experiences and hypersexuality occurs during manic episodes. Up to now, studies focused on sexual side effects of drugs. Sexual violence, sexually transmitted diseases, contraception methods, unplanned pregnancies need to be assessed carefully in bipolar disorder patients. This review focused on sexuality and sexual dysfunctions in the course of bipolar disorder. [Psikiyatride Guncel Yaklasimlar - Current Approaches in Psychiatry 2016; 8(4.000: 309-320

  17. Ion bipolar junction transistors.

    Science.gov (United States)

    Tybrandt, Klas; Larsson, Karin C; Richter-Dahlfors, Agneta; Berggren, Magnus

    2010-06-01

    Dynamic control of chemical microenvironments is essential for continued development in numerous fields of life sciences. Such control could be achieved with active chemical circuits for delivery of ions and biomolecules. As the basis for such circuitry, we report a solid-state ion bipolar junction transistor (IBJT) based on conducting polymers and thin films of anion- and cation-selective membranes. The IBJT is the ionic analogue to the conventional semiconductor BJT and is manufactured using standard microfabrication techniques. Transistor characteristics along with a model describing the principle of operation, in which an anionic base current amplifies a cationic collector current, are presented. By employing the IBJT as a bioelectronic circuit element for delivery of the neurotransmitter acetylcholine, its efficacy in modulating neuronal cell signaling is demonstrated.

  18. Pacemakers and implantable cardioverter defibrillators - general and anesthetic considerations

    Directory of Open Access Journals (Sweden)

    Amy G. Rapsang

    2014-06-01

    Full Text Available A pacemaking system consists of an impulse generator and lead or leads to carry the electrical impulse to the patient's heart. Pacemaker and implantable cardioverter defibrillator codes were made to describe the type of pacemaker or implantable cardioverter defibrillator implanted. Indications for pacing and implantable cardioverter defibrillator implantation were given by the American College of Cardiologists. Certain pacemakers have magnet-operated reed switches incorporated; however, magnet application can have serious adverse effects; hence, devices should be considered programmable unless known otherwise. When a device patient undergoes any procedure (with or without anesthesia, special precautions have to be observed including a focused history/physical examination, interrogation of pacemaker before and after the procedure, emergency drugs/temporary pacing and defibrillation, reprogramming of pacemaker and disabling certain pacemaker functions if required, monitoring of electrolyte and metabolic disturbance and avoiding certain drugs and equipments that can interfere with pacemaker function. If unanticipated device interactions are found, consider discontinuation of the procedure until the source of interference can be eliminated or managed and all corrective measures should be taken to ensure proper pacemaker function should be done. Post procedure, the cardiac rate and rhythm should be monitored continuously and emergency drugs and equipments should be kept ready and consultation with a cardiologist or a pacemaker-implantable cardioverter defibrillator service may be necessary.

  19. Pacemaker recycling: A notion whose time has come.

    Science.gov (United States)

    Runge, Mason W; Baman, Timir S; Davis, Sheldon; Weatherwax, Kevin; Goldman, Ed; Eagle, Kim A; Crawford, Thomas C

    2017-04-26

    The purpose of this paper is to summarize the need, feasibility, safety, legality, and ethical perspectives of pacemaker reutilization in low- and middle-income countries (LMICs). It will also describe, in-depth, Project My Heart Your Heart (PMHYH) as a model for pacemaker reuse in LMICs. The primary source of the discussion points in this paper is a collection of 14 publications produced by the research team at the University of Michigan and its collaborative partners. The need for pacemaker reutilization in LMICs is evident. Numerous studies show that the concept of pacemaker reutilization in LMICs is feasible. Infection and device malfunction are the main concerns in regard to pacemaker reutilization, yet many studies have shown that pacemaker reuse is not associated with increased infection risk or higher mortality compared with new device implantation. Under the right circumstances, the ethical and legal bases for pacemaker reutilization are supported. PMHYH is a proof of concept pacemaker donation initiative that has allowed funeral home and crematory directors to send explanted devices to an academic center for evaluation and re-sterilization before donation to underserved patients in LMICs. The time is now to pursue large-scale studies and trials of pacemaker reuse for the betterment of society. PMHYH is leading the way in the effort and is poised to conduct a prospective randomized, non-inferiority, multicenter study to confirm the clinical efficacy and safety of pacemaker reuse, for clinical and legal support.

  20. Pacemaker deactivation: withdrawal of support or active ending of life?

    Science.gov (United States)

    Huddle, Thomas S; Amos Bailey, F

    2012-12-01

    In spite of ethical analyses assimilating the palliative deactivation of pacemakers to commonly accepted withdrawings of life-sustaining therapy, many clinicians remain ethically uncomfortable with pacemaker deactivation at the end of life. Various reasons have been posited for this discomfort. Some cardiologists have suggested that reluctance to deactivate pacemakers may stem from a sense that the pacemaker has become part of the patient's "self." The authors suggest that Daniel Sulmasy is correct to contend that any such identification of the pacemaker is misguided. The authors argue that clinicians uncomfortable with pacemaker deactivation are nevertheless correct to see it as incompatible with the traditional medical ethics of withdrawal of support. Traditional medical ethics is presently taken by many to sanction pacemaker deactivation when such deactivation honors the patient's right to refuse treatment. The authors suggest that the right to refuse treatment applies to treatments involving ongoing physician agency. This right cannot underwrite patient demands that physicians reverse the effects of treatments previously administered, in which ongoing physician agency is no longer implicated. The permanently indwelling pacemaker is best seen as such a treatment. As such, its deactivation in the pacemaker-dependent patient is best seen not as withdrawal of support but as active ending of life. That being the case, clinicians adhering to the usual ethical analysis of withdrawal of support are correct to be uncomfortable with pacemaker deactivation at the end of life.

  1. Magnetic Resonance Imaging in Nondependent Pacemaker Patients with Pacemakers and Defibrillators with a Nearly Depleted Battery.

    Science.gov (United States)

    Okamura, Hideo; Padmanabhan, Deepak; Watson, Robert E; Dalzell, Connie; Acker, Nancy; Jondal, Mary; Romme, Abby L; Cha, Yong-Mei; Asirvatham, Samuel J; Felmlee, Joel P; Friedman, Paul A

    2017-05-01

    Magnetic resonance imaging (MRI) in patients with non-MRI-conditional cardiac implantable electronic devices (CIEDs) has been shown to be safe when performed under closely monitored protocols. However, the safety of MRI in patients with devices with a nearly depleted battery has not been reported. Prospective data were collected between January 2008 and May 2015 in patients with non-MRI-conditional CIEDs undergoing clinically indicated MRI under institutional protocol. Patients who were pacemaker dependent were excluded. Patients whose devices were at elective replacement indicator (ERI) at the time of MRI or close to ERI (ERI or replacement for battery depletion within 3 months of scan) were identified through database review and analyzed for clinical events. MRI scans (n = 569) were performed in 442 patients. Of these, we identified 13 scans performed with a nearly depleted battery in nine patients. All scans with implantable cardioverter defibrillators (ICDs, n = 9) were uneventful. However, two scans with pacemakers close to ERI resulted in a power-on-reset (PoR) event. One scan with a pacemaker close to ERI that was programmed to DOO mode reached ERI during MRI and automatically changed to VVI mode. Additionally, one scan with a pacemaker at ERI did not allow programming. All pacemakers with events were implanted before 2005. Patients with pacemakers and ICDs with a nearly depleted battery can safely undergo MRI when patients are not pacemaker dependent. Attention should be paid because old devices can result in PoR or ERI during MRI, which may lead to oversensing and inhibition of pacing. © 2017 Wiley Periodicals, Inc.

  2. Excitation model of pacemaker cardiomyocytes of cardiac conduction system

    Science.gov (United States)

    Grigoriev, M.; Babich, L.

    2015-11-01

    Myocardium includes typical and atypical cardiomyocytes - pacemakers, which form the cardiac conduction system. Excitation from the atrioventricular node in normal conditions is possible only in one direction. Retrograde direction of pulses is impossible. The most important prerequisite for the work of cardiomyocytes is the anatomical integrity of the conduction system. Changes in contractile force of the cardiomyocytes, which appear periodically, are due to two mechanisms of self-regulation - heterometric and homeometric. Graphic course of the excitation pulse propagation along the heart muscle more accurately reveals the understanding of the arrhythmia mechanism. These models have the ability to visualize the essence of excitation dynamics. However, they do not have the proper forecasting function for result estimation. Integrative mathematical model enables further investigation of general laws of the myocardium active behavior, allows for determination of the violation mechanism of electrical and contractile function of cardiomyocytes. Currently, there is no full understanding of the topography of pacemakers and ionic mechanisms. There is a need for the development of direction of mathematical modeling and comparative studies of the electrophysiological arrangement of cells of atrioventricular connection and ventricular conduction system.

  3. Integrated Neurobiology of Bipolar Disorder

    Science.gov (United States)

    Maletic, Vladimir; Raison, Charles

    2014-01-01

    From a neurobiological perspective there is no such thing as bipolar disorder. Rather, it is almost certainly the case that many somewhat similar, but subtly different, pathological conditions produce a disease state that we currently diagnose as bipolarity. This heterogeneity – reflected in the lack of synergy between our current diagnostic schema and our rapidly advancing scientific understanding of the condition – limits attempts to articulate an integrated perspective on bipolar disorder. However, despite these challenges, scientific findings in recent years are beginning to offer a provisional “unified field theory” of the disease. This theory sees bipolar disorder as a suite of related neurodevelopmental conditions with interconnected functional abnormalities that often appear early in life and worsen over time. In addition to accelerated loss of volume in brain areas known to be essential for mood regulation and cognitive function, consistent findings have emerged at a cellular level, providing evidence that bipolar disorder is reliably associated with dysregulation of glial–neuronal interactions. Among these glial elements are microglia – the brain’s primary immune elements, which appear to be overactive in the context of bipolarity. Multiple studies now indicate that inflammation is also increased in the periphery of the body in both the depressive and manic phases of the illness, with at least some return to normality in the euthymic state. These findings are consistent with changes in the hypothalamic–pituitary–adrenal axis, which are known to drive inflammatory activation. In summary, the very fact that no single gene, pathway, or brain abnormality is likely to ever account for the condition is itself an extremely important first step in better articulating an integrated perspective on both its ontological status and pathogenesis. Whether this perspective will translate into the discovery of innumerable more homogeneous forms of

  4. Electronic monitoring in bipolar disorder.

    Science.gov (United States)

    Faurholt-Jepsen, Maria

    2018-03-01

    Major reasons for the insufficient effects of current treatment options in bipolar disorder include delayed intervention for prodromal depressive and manic symptoms and decreased adherence to psychopharmacological treatment. The reliance on subjective information and clinical evaluations when diagnosing and assessing the severity of depressive and manic symptoms calls for less biased and more objective markers. By using electronic devices, fine-grained data on complex psychopathological aspects of bipolar disorder can be evaluated unobtrusively over the long term. Moreover, electronic data could possibly represent candidate markers of diagnosis and illness activity in bipolar disorder and allow for early and individualized intervention for prodromal symptoms outside clinical settings. 
The present dissertation concerns the use of electronic monitoring as a marker and treatment intervention in bipolar disorder and investigated the scientific literature and body of evidence within the area, which includes ten original study reports and two systematic reviews, one of which included a meta-analysis, conducted by the author of the dissertation. 
Taken together, the literature presented in this dissertation illustrates that 1) smartphone-based electronic self-monitoring of mood seems to reflect clinically assessed depressive and manic symptoms and enables the long-term characterization of mood

instability in bipolar disorder; 2) preliminary results suggest that smartphone-based automatically generated data (e.g. the number of text messages sent/day; the number of incoming and outgoing calls/day; the number of changes in cell tower IDs/day; and voice features) seem to reflect clinically assessed depressive and manic symptoms in bipolar disorder; 3) smartphone-based electronic self-monitoring had no effects on the severity of depressive and manic symptoms in bipolar disorder, according to a randomized controlled trial; and 4) electronic monitoring of psychomotor

  5. Bipolar soft connected, bipolar soft disconnected and bipolar soft compact spaces

    Directory of Open Access Journals (Sweden)

    Muhammad Shabir

    2017-06-01

    Full Text Available Bipolar soft topological spaces are mathematical expressions to estimate interpretation of data frameworks. Bipolar soft theory considers the core features of data granules. Bipolarity is important to distinguish between positive information which is guaranteed to be possible and negative information which is forbidden or surely false. Connectedness and compactness are the most important fundamental topological properties. These properties highlight the main features of topological spaces and distinguish one topology from another. Taking this into account, we explore the bipolar soft connectedness, bipolar soft disconnectedness and bipolar soft compactness properties for bipolar soft topological spaces. Moreover, we introduce the notion of bipolar soft disjoint sets, bipolar soft separation, and bipolar soft hereditary property and study on bipolar soft connected and disconnected spaces. By giving the detailed picture of bipolar soft connected and disconnected spaces we investigate bipolar soft compact spaces and derive some results related to this concept.

  6. Pacemaker lead related tricuspid stenosis: a report of two cases

    OpenAIRE

    Heaven, D; Henein, M; Sutton, R

    2000-01-01

    Only four cases of tricuspid stenosis related to endocardial pacemaker leads have been reported. Two further cases associated with perforation of a tricuspid valve leaflet by a pacemaker lead are presented: a 46 year old woman and a 60 year old man. It is possible that tricuspid valve disease related to endocardial pacemaker and non-thoracotomy defibrillator leads is underrecognised. Diagnosis requires clinical suspicion and the use of Doppler echocardiography. Recent evidence of fibrosis aff...

  7. Genetics of bipolar disorder.

    Science.gov (United States)

    Kerner, Berit

    2014-01-01

    Bipolar disorder is a common, complex genetic disorder, but the mode of transmission remains to be discovered. Many researchers assume that common genomic variants carry some risk for manifesting the disease. The research community has celebrated the first genome-wide significant associations between common single nucleotide polymorphisms (SNPs) and bipolar disorder. Currently, attempts are under way to translate these findings into clinical practice, genetic counseling, and predictive testing. However, some experts remain cautious. After all, common variants explain only a very small percentage of the genetic risk, and functional consequences of the discovered SNPs are inconclusive. Furthermore, the associated SNPs are not disease specific, and the majority of individuals with a "risk" allele are healthy. On the other hand, population-based genome-wide studies in psychiatric disorders have rediscovered rare structural variants and mutations in genes, which were previously known to cause genetic syndromes and monogenic Mendelian disorders. In many Mendelian syndromes, psychiatric symptoms are prevalent. Although these conditions do not fit the classic description of any specific psychiatric disorder, they often show nonspecific psychiatric symptoms that cross diagnostic boundaries, including intellectual disability, behavioral abnormalities, mood disorders, anxiety disorders, attention deficit, impulse control deficit, and psychosis. Although testing for chromosomal disorders and monogenic Mendelian disorders is well established, testing for common variants is still controversial. The standard concept of genetic testing includes at least three broad criteria that need to be fulfilled before new genetic tests should be introduced: analytical validity, clinical validity, and clinical utility. These criteria are currently not fulfilled for common genomic variants in psychiatric disorders. Further work is clearly needed before genetic testing for common variants in

  8. High rate lithium-thionyl chloride bipolar battery development

    Energy Technology Data Exchange (ETDEWEB)

    Russell, P.G.; Goebel, F. [Yardney Technical Products, Inc., Pawcatuck, CT (United States)

    1994-12-31

    The lithium/thionyl chloride system is capable of providing both high power and high energy density when cells containing thin components are arranged in a bipolar configuration. Electrode current densities in excess of 300mA/cm{sup 2} are achieved during pulse discharge. The present work is concerned with bipolar cell design, cathode evaluation, component manufacturing methods, and the assembly and testing of bipolar modules containing up to 150 cells.

  9. The rationale and design of the Micra Transcatheter Pacing Study: safety and efficacy of a novel miniaturized pacemaker.

    Science.gov (United States)

    Ritter, Philippe; Duray, Gabor Z; Zhang, Shu; Narasimhan, Calambur; Soejima, Kyoko; Omar, Razali; Laager, Verla; Stromberg, Kurt; Williams, Eric; Reynolds, Dwight

    2015-05-01

    Recent advances in miniaturization technologies and battery chemistries have made it possible to develop a pacemaker small enough to implant within the heart while still aiming to provide similar battery longevity to conventional pacemakers. The Micra Transcatheter Pacing System is a miniaturized single-chamber pacemaker system that is delivered via catheter through the femoral vein. The pacemaker is implanted directly inside the right ventricle of the heart, eliminating the need for a device pocket and insertion of a pacing lead, thereby potentially avoiding some of the complications associated with traditional pacing systems. The Micra Transcatheter Pacing Study is currently undergoing evaluation in a prospective, multi-site, single-arm study. Approximately 720 patients will be implanted at up to 70 centres around the world. The study is designed to have a continuously growing body of evidence and data analyses are planned at various time points. The primary safety and efficacy objectives at 6-month post-implant are to demonstrate that (i) the percentage of Micra patients free from major complications related to the Micra system or implant procedure is significantly higher than 83% and (ii) the percentage of Micra patients with both low and stable thresholds is significantly higher than 80%. The safety performance benchmark is based on a reference dataset of 977 subjects from 6 recent pacemaker studies. The Micra Transcatheter Pacing Study will assess the safety and efficacy of a miniaturized, totally endocardial pacemaker in patients with an indication for implantation of a single-chamber ventricular pacemaker. NCT02004873. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2015. For permissions please email: journals.permissions@oup.com.

  10. Recurrent syncope in a hypertensive subject with vascular cognitive impairment and permanent pacemaker

    Directory of Open Access Journals (Sweden)

    Alberto Mazza

    2012-09-01

    Full Text Available Syncope following permanent pacemaker (PM implantation is a nightmare for electrophysiologists. We describe a case of daily recurrent syncope in an 84-year-old man having a dual-chamber pacemaker implanted for complete atrio-ventricular block occurred 4 years before the admission to our department. He had a history of arterial hypertension, parossistic atrial fibrillation, chronic obstructive pulmonary disease, stage-III chronic renal failure, mild vascular cognitive impairment and glaucoma. The initial work-up including electrocardiogram (ECG, repeated PM inter- rogations, Holter electrocardiogram, blood pressure measurement in orthostatic position, complete blood count, serum glycaemia, electrolytes and thyroid function tests showed normal findings. Syncope occurred in lying position and during 90° left clockwise neck rotation and was associated to pallor, sweating, tonic-clonic seizures and transient self-limited loss of consciousness lasting a few seconds. Electroencephalogram was normal. During continuous ECG monitoring, the right rotation of the head determined a ventricular asystolic pause lasting 9 seconds associated with loss of consciousness. Restoration of sinus rhythm was observed after bringing back the head in axis. The PM interrogation, performed during pacing failure, recorded low impedance of bipolar ventricular lead, suggesting a damage in lead insulation. It is likely that lead movements during clockwise neck rotation produced an intermittent short circuit that prevented sufficient energy delivery to the myocardium with a consequence of sudden loss of capture.

  11. 76 FR 53851 - Effective Date of Requirement for Premarket Approval for Cardiovascular Permanent Pacemaker...

    Science.gov (United States)

    2011-08-30

    ... Approval for Cardiovascular Permanent Pacemaker Electrode; Correction AGENCY: Food and Drug Administration... development protocol for the class III preamendments device: Cardiovascular permanent pacemaker electrode. The...

  12. Cardiac pacemakers in magnetic fields of a shunt reactor at a 400 kV substation.

    Science.gov (United States)

    Korpinen, Leena; Kuisti, Harri; Tarao, Hiroo; Elovaara, Jarmo; Virtanen, Vesa

    2015-01-01

    The use of cardiac pacemakers (PMs) increases in Western countries. The aim of the study is to investigate cardiac pacemakers (PMs) using a human-shaped phantom in magnetic fields of a shunt reactor at a 400 kV substation. We performed seven PM experiments using a phantom. Two locations close to the shunt reactors were chosen. The magnetic field exposure was over 1000 µT in one location and over 600 µT in the other one. The magnetic field exposure did not disturb the tested five different PMs (in unipolar or bipolar configurations). It can be stated that in our experiment, the magnetic field exposure (over 600 µT and over 1000 µT) did not disturb the PMs (in unipolar or bipolar configurations). Since we only studied some PMs, it is possible that the magnetic field exposure at 400 kV substations can cause disturbances to other PMs. However, the risk of disturbances does not seem to be high.

  13. Novel approach to epicardial pacemaker implantation in patients with limited venous access.

    Science.gov (United States)

    Costa, Roberto; Scanavacca, Mauricio; da Silva, Kátia Regina; Martinelli Filho, Martino; Carrillo, Roger

    2013-11-01

    Limited venous access in certain patients increases the procedural risk and complexity of conventional transvenous pacemaker implantation. The purpose of this study was to determine a minimally invasive epicardial approach using pericardial reflections for dual-chamber pacemaker implantation in patients with limited venous access. Between June 2006 and November 2011, 15 patients underwent epicardial pacemaker implantation. Procedures were performed through a minimally invasive subxiphoid approach and pericardial window with subsequent fluoroscopy-assisted lead placement. Mean patient age was 46.4 ± 15.3 years (9 male [(60.0%], 6 female [40.0%]). The new surgical approach was used in patients determined to have limited venous access due to multiple abandoned leads in 5 (33.3%), venous occlusion in 3 (20.0%), intravascular retention of lead fragments from prior extraction in 3 (20.0%), tricuspid valve vegetation currently under treatment in 2 (13.3%), and unrepaired intracardiac defects in 2 (13.3%). All procedures were successful with no perioperative complications or early deaths. Mean operating time for isolated pacemaker implantation was 231.7 ± 33.5 minutes. Lead placement on the superior aspect of right atrium, through the transverse sinus, was possible in 12 patients. In the remaining 3 patients, the atrial lead was implanted on the left atrium through the oblique sinus, the postcaval recess, or the left pulmonary vein recess. None of the patients displayed pacing or sensing dysfunction, and all parameters remained stable throughout the follow-up period of 36.8 ± 25.1 months. Epicardial pacemaker implantation through pericardial reflections is an effective alternative therapy for those patients requiring physiologic pacing in whom venous access is limited. © 2013 Heart Rhythm Society. All rights reserved.

  14. Percutaneously injectable fetal pacemaker: electronics, pacing thresholds, and power budget.

    Science.gov (United States)

    Nicholson, Adriana; Chmait, Ramen; Bar-Cohen, Yaniv; Zheng, Kaihui; Loeb, Gerald E

    2012-01-01

    We are developing a cardiac pacemaker that is designed to be implanted percutaneously into a fetus to treat complete heart block and consequent hydrops fetalis, which is otherwise fatal. One of the most significant considerations for this device is the technical challenges presented by the battery and charging system. The size of the device is limited to about 3 mm in diameter; batteries on this scale have very small charge capacities. The smaller capacity means that the device needs to be designed so that it uses as little current as possible and so that its battery can be recharged wirelessly. We determined the pacing thresholds for a simple relaxation oscillator that can be assembled from discrete, surface mount components and analyzed the power consumption of the device given different electrode configurations and stimulus parameters. An inductive recharging system will be required for some patients; it is feasible within the package constraints and under development.

  15. Bipolar Disorder - Multiple Languages

    Science.gov (United States)

    ... MP3 Bipolar Disorder (An Introduction) - English MP4 Bipolar Disorder (An Introduction) - español (Spanish) MP4 Healthy Roads Media Characters not displaying correctly on this page? See language display issues . Return to the MedlinePlus Health Information ...

  16. A Functional Analysis of Circadian Pacemakers in Nocturnal Rodents. IV. Entrainment : Pacemaker as Clock

    NARCIS (Netherlands)

    Pittendrigh, Colin S.; Daan, Serge

    1976-01-01

    1. In the first part of the paper, the model of non-parametric entrainment of circadian pacemakers is tested for the case of nocturnal rodents. The model makes use of the available data on freerunning period (τ) in constant darkness and on phase response curves (PRC) for short light pulses. It is

  17. Cardiovascular patients' experiences of living with pacemaker: Qualitative study.

    Science.gov (United States)

    Ghojazadeh, Morteza; Azami-Aghdash, Saber; Sohrab-Navi, Zahra; Kolahdouzan, Kasra

    2015-09-01

    A pacemaker implantation is considered major life event for cardiovascular patients, so they will probably have very interesting experiences of living with this device. The aim of this study was to explore the experiences of cardiovascular patients living with the pacemaker. In this qualitative study, 27 patients were chosen through purposive sampling to achieve data saturation, and their experiences were examined using semi-structured interviews. The patients' statements were recorded with their consent and analyzed using content analysis method. Participants' experiences included three main themes: "Problems and limitations," "feeling and dealing with pacemaker", and "sources of comfort" and 10 sub-themes including: physical problems, financial problems, social problems, the first encounter, the feeling of living with the pacemaker, how to cope with pacemaker, satisfaction with pacemaker, good family support, hospital and hospital staff performance, and role of religious beliefs. Planning to solve social problems, identifying and changing feelings of patients using pacemakers, reinforcing the resources of comfort especially family support seem to be necessary steps for improving quality of life and impact of using pacemaker.

  18. Pelvic-floor rehabilitation, Part 1: Comparison of two surface electrode placements during stimulation of the pelvic-floor musculature in women who are continent using bipolar interferential currents.

    Science.gov (United States)

    Dumoulin, C; Seaborne, D E; Quirion-DeGirardi, C; Sullivan, S J

    1995-12-01

    Electrical stimulation of the pelvic floor is used as an adjunct in the conservative treatment of urinary incontinence. No consensus exists, however, regarding electrode placements for optimal stimulation of the pelvic-floor musculature. The purpose of this study was to compare two different bipolar electrode placements, one suggested by Laycock and Green (L2) the other by Dumoulin (D2), during electrical stimulation with interferential currents of the pelvic-floor musculature in continent women, using a two-group crossover design. Ten continent female volunteers, ranging in age from 20 to 39 years (mean = 27.3, SD = 5.6), were randomly assigned to one of two study groups. Each study group received neuromuscular electrical stimulation (NMES) of the pelvic-floor musculature using both electrode placements, the order of application being reversed for each group. Force of contraction was measured as pressure (in centimeters of water [cm H2O]) exerted on a vaginal pressure probe attached to a manometer. Data were analyzed using a two-way, mixed-model analysis of variance. No difference in pressure was observed between the two electrode placements. Differences in current amplitude were observed, with the D2 electrode placement requiring less current amplitude to produce a maximum recorded pressure on the manometer. Subjective assessment by the subjects revealed a preference for the D2 electrode placement (7 of 10 subjects). The lower current amplitudes required with the D2 placement to obtain recordings comparable to those obtained with the L2 technique suggest a more comfortable stimulation of the pelvic-floor muscles. The lower current amplitudes required also suggest that greater increases in pressure might be obtained with the D2 placement by increasing the current amplitude while remaining within the comfort threshold. These results will help to define treatment guidelines for a planned clinical study investigating the effects of NMES and exercise in the treatment

  19. Electrical resistivity change in Al:ZnO thin films dynamically deposited by bipolar pulsed direct-current sputtering and a remote plasma source

    International Nuclear Information System (INIS)

    Yang, Wonkyun; Joo, Junghoon

    2010-01-01

    The Al-doped ZnO (AZO) thin films for a transparent conducting oxide in solar cell devices were deposited by bipolar pulsed dc magnetron sputtering. This work was performed in an in-line type system and investigated AZO films in a static deposition mode and dynamic one, which is more important in the practical fields. Because of this dynamic deposition process, the zigzagged columnar structure was observed. This resulted in the decreasing electrical property, optical properties, and surface roughness. As a deposition in the dynamic mode, the resistivity increased from 1.64x10 -3 to 2.50x10 -3 Ω cm, as compared to that in the static mode, and the transmittance also decreased from 83.9% to 78.3%. To recover the disadvantage, a remote plasma source (RPS) was supported between the substrate and target for reducing zigzagged formation during the deposition. The deposition rate decreased by using RPS, but the electrical and optical properties of films got better than only dynamic mode. The resistivity and transmittance in the dynamic mode using RPS were 2.1x10 -3 Ω cm and 85.5%, respectively. In this study, the authors found the possibility to advance the electrical and optical properties of AZO thin films in the industry mode.

  20. The cardiac pacemaker patient. Might the pacer be directly irradiated?

    International Nuclear Information System (INIS)

    Tsekos, A.; Momm, F.; Brunner, M.; Guttenberger, R.

    2000-01-01

    According to recommendations listed in a recent review, pacemakers generally should not be irradiated directly. They should be shielded from ionizing radiation or their position changed. Direct irradiation can cause pacemaker failure. There are no clinical signals to indicate a near failure. When controlling pacemaker function, there is often a change in the magnetic frequency before malfunction occurs. If a malfunction results in a partial heart failure only, there would be enough time to implant another pacemaker. As can be seen from a case described here, a policy of 'wait and see' may be adopted even if there are changes in the magnetic frequency. if there is any danger to the patient's life, the feasibility of using an external pacemaker system may be explored, especially in cases where there is a strong need for radiotherapy (severe pain, infiltration of plexus). Risks and benefits should be carefully weighed and discussed with the patient

  1. Properties of Bipolar Fuzzy Hypergraphs

    OpenAIRE

    Akram, M.; Dudek, W. A.; Sarwar, S.

    2013-01-01

    In this article, we apply the concept of bipolar fuzzy sets to hypergraphs and investigate some properties of bipolar fuzzy hypergraphs. We introduce the notion of $A-$ tempered bipolar fuzzy hypergraphs and present some of their properties. We also present application examples of bipolar fuzzy hypergraphs.

  2. Clear cell hidradenocarcinoma developing in pacemaker pocket.

    Science.gov (United States)

    Reyes, Cesar V

    2008-11-01

    An octagenerian woman developed clear cell hidradenocarcinoma, a rare neoplasm of eccrine sweat gland origin, 4 years following pacemaker implantation in her right lateral chest. The tumor immunohistochemically mimicked a metastatic lobular breast carcinoma, for example, strongly positive estrogen, weakly positive progesterone, and weakly reactive mammoglobin. A complete surgical excision of the tumor was complemented with ipsilateral dissection of involved adjacent axillary lymph nodes. Recommended irradiation was refused by the patient. Retrospective 3-year mammogram review, 2-year postsurgery follow-up, and complete postmortem evaluation failed to prove a primary breast malignancy or other metastatic lesion elsewhere.

  3. Pacemaker syndrome with sub-acute left ventricular systolic dysfunction in a patient with a dual-chamber pacemaker: consequence of lead switch at the header.

    Science.gov (United States)

    Khurwolah, Mohammad Reeaze; Vezi, Brian Zwelethini

    In the daily practice of pacemaker insertion, the occurrence of atrial and ventricular lead switch at the pacemaker box header is a rare and unintentional phenomenon, with less than five cases reported in the literature. The lead switch may have dire consequences, depending on the indication for the pacemaker. One of these consequences is pacemaker syndrome, in which the normal sequence of atrial and ventricular activation is impaired, leading to sub-optimal ventricular filling and cardiac output. It is important for the attending physician to recognise any worsening of symptoms in a patient who has recently had a permanent pacemaker inserted. In the case of a dual-chamber pacemaker, switching of the atrial and ventricular leads at the pacemaker box header should be strongly suspected. We present an unusual case of pacemaker syndrome and right ventricular-only pacinginduced left ventricular systolic dysfunction in a patient with a dual-chamber pacemaker.

  4. Pacemaker implantation complication rates in elderly and young patients

    Directory of Open Access Journals (Sweden)

    Özcan KS

    2013-08-01

    Full Text Available Kazim Serhan Özcan, Damirbek Osmonov, Servet Altay, Cevdet Dönmez, Ersin Yildirim, Ceyhan Türkkan, Baris Güngör, Ahmet Ekmekçi, Ahmet Taha Alper, Kadir Gürkan, İzzet ErdinlerDepartment of Cardiology, Siyami Ersek Cardiovascular and Thoracic Surgery Center, Istanbul, TurkeyAims: To evaluate the complication rate differences between elderly and younger patients who receive a permanent pacemaker implantation.Methods: We reviewed all cases admitted to our institution between January 2008 and June 2009 with symptomatic bradyarrhythmia for whom a permanent pacemaker was implanted. Beginning in June 2009, we prospectively collected data from all patients with the same diagnosis and procedure. The frequency of complications due to the pacemaker implantation procedure was evaluated and compared between young (<70 years old and elderly (≥70 years old patients.Results: Among 574 patients with a permanent pacemaker, 259 patients (45.1% were below and 315 patients (54.9% were above or at 70 years of age. There were 240 (92.7% and 19 (7.3% dual-chamber pacemaker (DDD and single-chamber pacemaker (VVI implanted patients in the younger group, and 291 (76.8% and 73 (23.2% DDD and VVI pacemaker implanted patients in the elderly group, respectively. The complication rate was 39 (15.1% out of 259 young patients and 24 (7.6% out of 315 elderly patients. Postprocedural complications were statistically lower in the elderly patients than in younger patients (P = 0.005.Conclusion: A pacemaker implantation performed by an experienced operator is a safe procedure for patients of advanced age. The patients who are above 70 years old may have less complication rates than the younger patients.Keywords: complications of pacemaker implantation, elderly patients, permanent pacemaker

  5. 76 FR 47085 - Effective Date of Requirement for Premarket Approval for a Pacemaker Programmer

    Science.gov (United States)

    2011-08-04

    ... Approval for a Pacemaker Programmer AGENCY: Food and Drug Administration, HHS. ACTION: Proposed rule... preamendments device pacemaker programmers. The agency is also summarizing its proposed findings regarding the... Subject to This Proposal--Pacemaker Programmers (21 CFR 870.3700) A. Identification A pacemaker programmer...

  6. 21 CFR 870.3680 - Cardiovascular permanent or temporary pacemaker electrode.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Cardiovascular permanent or temporary pacemaker... § 870.3680 Cardiovascular permanent or temporary pacemaker electrode. (a) Temporary pacemaker electrode—(1) Identification. A temporary pacemaker electrode is a device consisting of flexible insulated...

  7. Generation of locomotion rhythms without inhibition in vertebrates: the search for pacemaker neurons.

    Science.gov (United States)

    Li, Wen-Chang

    2011-12-01

    Locomotion rhythms are thought to be generated by neurons in the central-pattern-generator (CPG) circuit in the spinal cord. Synaptic connections in the CPG and pacemaker properties in certain CPG neurons, both may contribute to generation of the rhythms. In the half-center model proposed by Graham Brown a century ago, reciprocal inhibition plays a critical role. However, in all vertebrate preparations examined, rhythmic motor bursts can be induced when inhibition is blocked in the spinal cord. Without inhibition, neuronal pacemaker properties may become more important in generation of the rhythms. Pacemaker properties have been found in motoneurons and some premotor interneurons in different vertebrates and they can be dependent on N-Methyl-d-aspartate (NMDA) receptors (NMDAR) or rely on other ionic currents like persistent inward currents. In the swimming circuit of the hatchling Xenopus tadpole, there is substantial evidence that emergent network properties can give rise to swimming rhythms. During fictive swimming, excitatory interneurons (dINs) in the caudal hindbrain fire earliest on each swimming cycle and their spikes drive the firing of other CPG neurons. Regenerative dIN firing itself relies on reciprocal inhibition and background excitation. We now find that the activation of NMDARs can change dINs from firing singly at rest to current injection to firing repetitively at swimming frequencies. When action potentials are blocked, some intrinsic membrane potential oscillations at about 10 Hz are revealed, which may underlie repetitive dIN firing during NMDAR activation. In confirmation of this, dIN repetitive firing persists in NMDA when synaptic transmission is blocked by Cd(2+). When inhibition is blocked, only dINs and motoneurons are functional in the spinal circuit. We propose that the conditional intrinsic NMDAR-dependent pacemaker firing of dINs can drive the production of swimming-like rhythms without the participation of inhibitory

  8. Same-Single-Cell Analysis of Pacemaker-Specific Markers in Human Induced Pluripotent Stem Cell-Derived Cardiomyocyte Subtypes Classified by Electrophysiology

    Science.gov (United States)

    Yechikov, Sergey; Copaciu, Raul; Gluck, Jessica M.; Deng, Wenbin; Chiamvimonvat, Nipavan; Chan, James W.; Lieu, Deborah K.

    2018-01-01

    Insights into the expression of pacemaker-specific markers in human induced pluripotent stem cell (hiPSC)-derived cardiomyocyte subtypes can facilitate the enrichment and track differentiation and maturation of hiPSC-derived pacemaker-like cardiomyocytes. To date, no study has directly assessed gene expression in each pacemaker-, atria-, and ventricular-like cardiomyocyte subtype derived from hiPSCs since currently the subtypes of these immature cardiomyocytes can only be identified by action potential profiles. Traditional acquisition of action potentials using patch-clamp recordings renders the cells unviable for subsequent analysis. We circumvented these issues by acquiring the action potential profile of a single cell optically followed by assessment of protein expression through immunostaining in that same cell. Our same-single-cell analysis for the first time revealed expression of proposed pacemaker-specific markers—hyperpolarization-activated cyclic nucleotide-modulated (HCN)4 channel and Islet (Isl)1—at the protein level in all three hiPSC-derived cardiomyocyte subtypes. HCN4 expression was found to be higher in pacemaker-like hiPSC-derived cardiomyocytes than atrial- and ventricular-like subtypes but its downregulation over time in all subtypes diminished the differences. Isl1 expression in pacemaker-like hiPSC-derived cardiomyocytes was initially not statistically different than the contractile subtypes but did become statistically higher than ventricular-like cells with time. Our observations suggest that although HCN4 and Isl1 are differentially expressed in hiPSC-derived pacemaker-like relative to ventricular-like cardiomyocytes, these markers alone are insufficient in identifying hiPSC-derived pacemaker-like cardiomyocytes. PMID:27434649

  9. Neck Pain One Week after Pacemaker Generator Replacement.

    Science.gov (United States)

    Graham, Ross F; Wightman, John M

    2015-07-01

    The incidence of cardiac pacemaker implantation has risen markedly in the past three decades, making awareness of possible postprocedural complications critical to the emergency physician. This case is the first documented instance of internal jugular (IJ) deep vein thrombosis (DVT) from an uncomplicated pacemaker generator replacement. A patient presented to an Emergency Department with a 2-day history of mild left temporal headache migrating to his left neck. The patient did not volunteer this information, but review of systems revealed a temporary transvenous pacemaker inserted through the right IJ vein 1 week previously during a routine exchange of a left-sided cardiac pacemaker generator. Manipulation of the existing pacemaker wires entering the left subclavian vein was minimal. Computed tomographic angiography of the neck demonstrated near-complete thrombotic occlusion of the entire length of his left IJ vein. This required hospital admission for observation and treatment with anticoagulation. WHY SHOULD AN EMERGENCY PHYSICIAN BE AWARE OF THIS?: DVT, with thrombotic extension into adjacent vessels anywhere along the course of pacemaker wires, should be considered by the emergency provider in the evaluation of head, neck, or upper extremity symptoms after recent or remote implantation or manipulation of a transvenous cardiac pacemaker, including generator replacement. Failure to identify and treat appropriately could result in significant morbidity and mortality from airway edema, septic thrombophlebitis, superior vena cava syndrome, superior sagittal sinus thrombosis, or pulmonary embolism. Published by Elsevier Inc.

  10. Modern Perspectives on Numerical Modeling of Cardiac Pacemaker Cell

    Science.gov (United States)

    Maltsev, Victor A.; Yaniv, Yael; Maltsev, Anna V.; Stern, Michael D.; Lakatta, Edward G.

    2015-01-01

    Cardiac pacemaking is a complex phenomenon that is still not completely understood. Together with experimental studies, numerical modeling has been traditionally used to acquire mechanistic insights in this research area. This review summarizes the present state of numerical modeling of the cardiac pacemaker, including approaches to resolve present paradoxes and controversies. Specifically we discuss the requirement for realistic modeling to consider symmetrical importance of both intracellular and cell membrane processes (within a recent “coupled-clock” theory). Promising future developments of the complex pacemaker system models include the introduction of local calcium control, mitochondria function, and biochemical regulation of protein phosphorylation and cAMP production. Modern numerical and theoretical methods such as multi-parameter sensitivity analyses within extended populations of models and bifurcation analyses are also important for the definition of the most realistic parameters that describe a robust, yet simultaneously flexible operation of the coupled-clock pacemaker cell system. The systems approach to exploring cardiac pacemaker function will guide development of new therapies, such as biological pacemakers for treating insufficient cardiac pacemaker function that becomes especially prevalent with advancing age. PMID:24748434

  11. Routine chest radiography after permanent pacemaker implantation: Is it necessary?

    Directory of Open Access Journals (Sweden)

    Edwards N

    2005-01-01

    Full Text Available Background and Aims: Chest radiographs (CXRs are performed routinely after permanent pacemaker implantation to identify pacemaker lead position and exclude pneumothorax. We assessed the clinical value and need for this procedure. Design: Retrospective analysis of pacemaker data and CXRs following permanent pacemaker insertion between December 2002 and February 2004. Materials and Methods: Post-procedural CXRs were available in 125/126 consecutive patients after either first endocardial pacemaker implantation or insertion of at least one new lead. Subclavian vein puncture was used for venous access in all cases. CXRs were examined to establish the incidence of pneumothorax and assess pacing lead positions. The clinical records were examined in all patients who had subsequent CXRs or a further pacemaker procedure to identify the indication for these and to establish whether CXR had influenced patient management. Results: In total, 192 post-procedural CXRs were performed, either postero-anterior (PA and/or lateral views. Ventricular and/or atrial pacing lead contour and electrode position was considered radiographically appropriate in 86% CXRs. Fourteen per cent of post-procedural radiographs were considered to have radiologically sub-optimal pacemaker lead positioning. None of the patients with these "abnormal" radiographs experienced subsequent pacemaker complications or had further radiographs recorded at a later date. Later repeat CXRs were performed in 16 patients (13% but only 3 patients (2% had pacing abnormalities as the primary indication. All three had satisfactory pacing lead position on initial post-implantation and later radiographs, but required further procedures for lead re-positioning. Iatrogenic pneumothorax occurred in one patient (incidence 0.8% in our series. CXR confirmed the clinical diagnosis and allowed an assessment of size to guide treatment. Conclusion: Routine CXR after permanent pacemaker insertion is not necessary in

  12. Genetics of bipolar disorder

    OpenAIRE

    Kerner, Berit

    2014-01-01

    Berit Kerner Semel Institute for Neuroscience and Human Behavior, University of California, Los Angeles, Los Angeles, CA, USA Abstract: Bipolar disorder is a common, complex genetic disorder, but the mode of transmission remains to be discovered. Many researchers assume that common genomic variants carry some risk for manifesting the disease. The research community has celebrated the first genome-wide significant associations between common single nucleotide polymorphisms (SNPs) and bipolar ...

  13. Of pacemakers and statistics: the actuarial method extended.

    Science.gov (United States)

    Dussel, J; Wolbarst, A B; Scott-Millar, R N; Obel, I W

    1980-01-01

    Pacemakers cease functioning because of either natural battery exhaustion (nbe) or component failure (cf). A study of four series of pacemakers shows that a simple extension of the actuarial method, so as to incorporate Normal statistics, makes possible a quantitative differentiation between the two modes of failure. This involves the separation of the overall failure probability density function PDF(t) into constituent parts pdfnbe(t) and pdfcf(t). The approach should allow a meaningful comparison of the characteristics of different pacemaker types.

  14. Acute pericarditis with cardiac tamponade induced by pacemaker implantation.

    Science.gov (United States)

    Shingaki, Masami; Kobayashi, Yutaka; Suzuki, Haruo

    2015-11-01

    An 87-year-old woman was diagnosed with third-degree atrioventricular block and underwent pacemaker implantation. On postoperative day 12, she experienced cardiac tamponade that was suspected on computed tomography to be caused by lead perforation; therefore, we performed open-heart surgery. However, we could not identify a perforation site on the heart, and drained a 400-mL exudative pericardial effusion. Subsequently, we diagnosed the pericardial effusion as due to pericarditis induced by pacemaker implantation. It is sometimes difficult to distinguish pericarditis from pacemaker lead perforation, so both should be included in the differential diagnosis. © The Author(s) 2014.

  15. Allergy to pacemaker silicone compounds: recognition and surgical management.

    Science.gov (United States)

    Oprea, Mihaela L; Schnöring, Heike; Sachweh, Jörg S; Ott, Hagen; Biertz, Julia; Vazquez-Jimenez, Jaime F

    2009-04-01

    Silicone is a widely used biomaterial. Contact allergy, particularly to silicone components of pacemaker coatings, is uncommon. We present a 12-year-old girl with a history of complex congenital heart disease and acquired complete heart block excluding transvenous lead placement. Contact allergy to silicone led to multiple surgical interventions until the etiology for recurrent pacemaker wound complications was discovered. The key to diagnosis was a specific manufacturer's patch test. Complete removal of the former pacing system and placement of custom-made silicone free pacemaker components and epicardial use of silicone free transvenous leads were essential for successful therapy.

  16. [Twiddler's syndrome as the cause of pacemaker electrode displacement].

    Science.gov (United States)

    Grønbech, Keea Treu; Hansen, Michael Gilså

    2013-04-08

    Twiddler's syndrome is a rare cause of pacemaker electrode displacement. The displacement is caused by the patient's manipulation with the pacemaker, so the electrode is retracted. We describe a case of a 79-year-old overweight woman with a known psychiatric anamnesis, who was admitted twice with twiddler's syndrome. Age and overweight are known risk factors for twiddler's syndrome; and in this case the patient's psychiatric habitus was probably an additional risk factor. Before performing a pacemaker implantation it is important to take the patient's risk factors into account, and thus consider submuscular implantation.

  17. [Genetics of bipolar disorder].

    Science.gov (United States)

    Budde, M; Forstner, A J; Adorjan, K; Schaupp, S K; Nöthen, M M; Schulze, T G

    2017-07-01

    Bipolar disorder (BD) has a multifactorial etiology. Its development is influenced by genetic as well as environmental factors. Large genome-wide association studies (GWAS), in which genetic risk allelic variants for the disorder could be replicated for the first time, marked the breakthrough in the identification of the responsible risk genes. In addition to these common genetic variants with moderate effects identified by GWAS, rare variants with a higher penetrance are expected to play a role in disease development. The results of recent studies suggest that copy number variants might contribute to BD development, although to a lesser extent than in other psychiatric disorders, such as schizophrenia or autism. Results from the initial next generation sequencing studies indicate an enrichment of rare variants in pathways and genes that were previously found to be associated with BD. In the field of pharmacogenetics, a risk gene that influences the individual variance in the response to lithium treatment was identified for the first time in a recent large international GWAS. Currently the reported risk alleles do not sufficiently explain the phenotypic variance to be used for individual prediction of disease risk, disease course or response to medication. Future genetic research will provide important insights into the biological basis of BD by the identification of additional genes associated with BD. This knowledge of genetics will help identify potential etiological subgroups as well as cross-diagnostic disease mechanisms.

  18. Nanofluidic diode and bipolar transistor.

    Science.gov (United States)

    Daiguji, Hirofumi; Oka, Yukiko; Shirono, Katsuhiro

    2005-11-01

    Theoretical modeling of ionic distribution and transport in a nanochannel containing a surface charge on its wall, 30 nm high and 5 microm long, suggests that ionic current can be controlled by locally modifying the surface charge density through a gate electrode, even if the electrical double layers are not overlapped. When the surface charge densities at the right and left halves of a channel are the same absolute value but of different signs, this could form the basis of a nanofluidic diode. When the surface charge density at the middle part of a channel is modified, this could form the basis of a nanofluidic bipolar transistor.

  19. Bipolar magnetic semiconductor in silicene nanoribbons

    Energy Technology Data Exchange (ETDEWEB)

    Farghadan, Rouhollah, E-mail: rfarghadan@kashanu.ac.ir

    2017-08-01

    Highlights: • A new electronic phase for silicene nanoribbon in the presence of electric and magnetic fields. • Bipolar magnetic semiconductor with controllable spin-flip and spin-conserved gaps in silicene. • Robust bipolar magnetic semiconductor features in a rough silicene. • Perfect and reversible spin polarization in silicene nanoribbon junctions. - Abstract: A theoretical study was presented on generation of spin polarization in silicene nanoribbons using the single-band tight-binding approximation and the non-equilibrium Green’s function formalism. We focused on the effect of electric and exchange magnetic fields on the spin-filter capabilities of zigzag-edge silicene nanoribbons in the presence of the intrinsic spin-orbit interaction. The results show that a robust bipolar magnetic semiconductor with controllable spin-flip and spin-conserved gaps can be obtained when exchange magnetic and electric field strengths are both larger than the intrinsic spin-orbit interaction. Therefore, zigzag silicene nanoribbons could act as bipolar and perfect spin filter devices with a large spin-polarized current and a reversible spin polarization in the vicinity of the Fermi energy. We also investigated the effect of edge roughness and found that the bipolar magnetic semiconductor features are robust against edge disorder in silicene nanoribbon junctions. These results may be useful in multifunctional spin devices based on silicene nanoribbons.

  20. Bipolar magnetic semiconductor in silicene nanoribbons

    International Nuclear Information System (INIS)

    Farghadan, Rouhollah

    2017-01-01

    Highlights: • A new electronic phase for silicene nanoribbon in the presence of electric and magnetic fields. • Bipolar magnetic semiconductor with controllable spin-flip and spin-conserved gaps in silicene. • Robust bipolar magnetic semiconductor features in a rough silicene. • Perfect and reversible spin polarization in silicene nanoribbon junctions. - Abstract: A theoretical study was presented on generation of spin polarization in silicene nanoribbons using the single-band tight-binding approximation and the non-equilibrium Green’s function formalism. We focused on the effect of electric and exchange magnetic fields on the spin-filter capabilities of zigzag-edge silicene nanoribbons in the presence of the intrinsic spin-orbit interaction. The results show that a robust bipolar magnetic semiconductor with controllable spin-flip and spin-conserved gaps can be obtained when exchange magnetic and electric field strengths are both larger than the intrinsic spin-orbit interaction. Therefore, zigzag silicene nanoribbons could act as bipolar and perfect spin filter devices with a large spin-polarized current and a reversible spin polarization in the vicinity of the Fermi energy. We also investigated the effect of edge roughness and found that the bipolar magnetic semiconductor features are robust against edge disorder in silicene nanoribbon junctions. These results may be useful in multifunctional spin devices based on silicene nanoribbons.

  1. Endocardial Pacemaker Implantation in Neonates and Infants

    Directory of Open Access Journals (Sweden)

    Canan Ayabakan

    2006-04-01

    Full Text Available Transvenous pacemaker lead implantation is the preferred method of pacing in adult patients. Lead performance and longevity are superior and the implantation approach can be performed under local anaesthetic with a very low morbidity. In children, and especially in neonates and infants, the epicardial route was traditionally chosen until the advent of smaller generators and lead implantation techniques that allowed growth of the child without lead displacement. Endocardial implantation is not universally accepted, however, as there is an incidence of venous occlusion of the smaller veins of neonates and infants with concerns for loss of venous access in the future. Growing experience with lower profile leads, however, reveals that endocardial pacing too can be performed with low morbidity and good long-term results in neonates and infants.

  2. Neutron absorbed dose in a pacemaker CMOS

    Energy Technology Data Exchange (ETDEWEB)

    Borja H, C. G.; Guzman G, K. A.; Valero L, C. Y.; Banuelos F, A.; Hernandez D, V. M.; Vega C, H. R. [Universidad Autonoma de Zacatecas, Unidad Academica de Estudios Nucleares, Calle Cipres No. 10, Fracc. La Penuela, 98068 Zacatecas (Mexico); Paredes G, L., E-mail: candy_borja@hotmail.com [ININ, Carretera Mexico-Toluca s/n, 52750 Ocoyoacac, Estado de Mexico (Mexico)

    2011-11-15

    The absorbed dose due to neutrons by a Complementary Metal Oxide Semiconductor (CMOS) has been estimated using Monte Carlo methods. Eventually a person with a pacemaker becomes a patient that must be treated by radiotherapy with a linear accelerator; the pacemaker has integrated circuits as CMOS that are sensitive to intense and pulsed radiation fields. When the Linac is working in Bremsstrahlung mode an undesirable neutron field is produced due to photoneutron reactions; these neutrons could damage the CMOS putting the patient at risk during the radiotherapy treatment. In order to estimate the neutron dose in the CMOS a Monte Carlo calculation was carried out where a full radiotherapy vault room was modeled with a W-made spherical shell in whose center was located the source term of photoneutrons produced by a Linac head operating in Bremsstrahlung mode at 18 MV. In the calculations a phantom made of tissue equivalent was modeled while a beam of photoneutrons was applied on the phantom prostatic region using a field of 10 x 10 cm{sup 2}. During simulation neutrons were isotropically transported from the Linac head to the phantom chest, here a 1 {theta} x 1 cm{sup 2} cylinder made of polystyrene was modeled as the CMOS, where the neutron spectrum and the absorbed dose were estimated. Main damages to CMOS are by protons produced during neutron collisions protective cover made of H-rich materials, here the neutron spectrum that reach the CMOS was calculated showing a small peak around 0.1 MeV and a larger peak in the thermal region, both connected through epithermal neutrons. (Author)

  3. Radiation Damage In Advanced Bipolar Transistors

    Science.gov (United States)

    Zoutendyk, John A.; Goben, Charles A.; Berndt, Dale F.

    1989-01-01

    Report describes measurements of common-emitter current gains (hFE) of advanced bipolar silicon transistors before, during, and after irradiation with 275-MeV bromine ions, 2.5-MeV electrons, and conductivity rays from cobalt-60 atoms.

  4. Intra-cardiac pacemaker infection: Surgical management and outcome

    Directory of Open Access Journals (Sweden)

    Sameh Elameen

    2016-05-01

    Conclusion: Explantation of the complete pacemaker system has proved a reliable method to eradicate infection. Complications were rare, except in patients who present lately in a critically ill condition and septic shock.

  5. Magnetic resonance imaging safety in pacemaker and implantable cardioverter defibrillator patients: how far have we come?

    Science.gov (United States)

    Nordbeck, Peter; Ertl, Georg; Ritter, Oliver

    2015-01-01

    Magnetic resonance imaging (MRI) has long been regarded a general contraindication in patients with cardiovascular implanted electronic devices such as cardiac pacemakers or cardioverter defibrillators (ICDs) due to the risk of severe complications and even deaths caused by interactions of the magnetic resonance (MR) surrounding and the electric devices. Over the last decade, a better understanding of the underlying mechanisms responsible for such potentially life-threatening complications as well as technical advances have allowed an increasing number of pacemaker and ICD patients to safely undergo MRI. This review lists the key findings from basic research and clinical trials over the last 20 years, and discusses the impact on current day clinical practice. With ‘MR-conditional’ devices being the new standard of care, MRI in pacemaker and ICD patients has been adopted to clinical routine today. However, specific precautions and specifications of these devices should be carefully followed if possible, to avoid patient risks which might appear with new MR technology and further increasing indications and patient numbers. PMID:25796053

  6. Complete atrial-specific knockout of sodium-calcium exchange eliminates sinoatrial node pacemaker activity.

    Directory of Open Access Journals (Sweden)

    Sabine Groenke

    Full Text Available The origin of sinoatrial node (SAN pacemaker activity in the heart is controversial. The leading candidates are diastolic depolarization by "funny" current (If through HCN4 channels (the "Membrane Clock" hypothesis, depolarization by cardiac Na-Ca exchange (NCX1 in response to intracellular Ca cycling (the "Calcium Clock" hypothesis, and a combination of the two ("Coupled Clock". To address this controversy, we used Cre/loxP technology to generate atrial-specific NCX1 KO mice. NCX1 protein was undetectable in KO atrial tissue, including the SAN. Surface ECG and intracardiac electrograms showed no atrial depolarization and a slow junctional escape rhythm in KO that responded appropriately to β-adrenergic and muscarinic stimulation. Although KO atria were quiescent they could be stimulated by external pacing suggesting that electrical coupling between cells remained intact. Despite normal electrophysiological properties of If in isolated patch clamped KO SAN cells, pacemaker activity was absent. Recurring Ca sparks were present in all KO SAN cells, suggesting that Ca cycling persists but is uncoupled from the sarcolemma. We conclude that NCX1 is required for normal pacemaker activity in murine SAN.

  7. Pacemaker lead fracture without an increase in lead impedance caused by cardiac fibroma

    Directory of Open Access Journals (Sweden)

    Daisuke Sato

    2013-12-01

    Full Text Available We report the case of a 64-year-old man who had a permanent pacemaker with a unipolar silicone electrode positioned in the right ventricle in 1989 for sinus node dysfunction. On a routine checkup in June 2011, a 28-mm-diameter mass was discovered, which appeared to adhere to the tricuspid valve and the ventricular lead. The size of the mass did not change for the next 6 months, and the lead impedance was maintained at around 500–600 Ω. Because pacing failure was observed in January 2012, he underwent an urgent pacemaker check; however, the lead impedance was found not to have increased greatly (689 Ω. Nevertheless, the pacemaker lead was noted to be fractured at the tricuspid level. His echocardiogram showed new severe tricuspid regurgitation and a floating mass around the lead. We extracted the fractured lead, enucleated the tumor, replaced the tricuspid valve, and placed an epicardial lead. Macroscopic examination revealed that the tumor surrounded the fractured lead and covered the stump. Pathological examination revealed that the tumor was composed of fibrous connective tissue. We presumed that electric current continued to flow through the stump of the fractured unipolar lead to the generator, and this might have caused the limited increase in lead impedance.

  8. From two competing oscillators to one coupled-clock pacemaker cell system

    Science.gov (United States)

    Yaniv, Yael; Lakatta, Edward G.; Maltsev, Victor A.

    2015-01-01

    At the beginning of this century, debates regarding “what are the main control mechanisms that ignite the action potential (AP) in heart pacemaker cells” dominated the electrophysiology field. The original theory which prevailed for over 50 years had advocated that the ensemble of surface membrane ion channels (i.e., “M-clock”) is sufficient to ignite rhythmic APs. However, more recent experimental evidence in a variety of mammals has shown that the sarcoplasmic reticulum (SR) acts as a “Ca2+-clock” rhythmically discharges diastolic local Ca2+ releases (LCRs) beneath the cell surface membrane. LCRs activate an inward current (likely that of the Na+/Ca2+ exchanger) that prompts the surface membrane “M-clock” to ignite an AP. Theoretical and experimental evidence has mounted to indicate that this clock “crosstalk” operates on a beat-to-beat basis and determines both the AP firing rate and rhythm. Our review is focused on the evolution of experimental definition and numerical modeling of the coupled-clock concept, on how mechanisms intrinsic to pacemaker cell determine both the heart rate and rhythm, and on future directions to develop further the coupled-clock pacemaker cell concept. PMID:25741284

  9. Successful pacing using a batteryless sunlight-powered pacemaker.

    Science.gov (United States)

    Haeberlin, Andreas; Zurbuchen, Adrian; Schaerer, Jakob; Wagner, Joerg; Walpen, Sébastien; Huber, Christoph; Haeberlin, Heinrich; Fuhrer, Juerg; Vogel, Rolf

    2014-10-01

    Today's cardiac pacemakers are powered by batteries with limited energy capacity. As the battery's lifetime ends, the pacemaker needs to be replaced. This surgical re-intervention is costly and bears the risk of complications. Thus, a pacemaker without primary batteries is desirable. The goal of this study was to test whether transcutaneous solar light could power a pacemaker. We used a three-step approach to investigate the feasibility of sunlight-powered cardiac pacing. First, the harvestable power was estimated. Theoretically, a subcutaneously implanted 1 cm(2) solar module may harvest ∼2500 µW from sunlight (3 mm implantation depth). Secondly, ex vivo measurements were performed with solar cells placed under pig skin flaps exposed to a solar simulator and real sunlight. Ex vivo measurements under real sunlight resulted in a median output power of 4941 µW/cm(2) [interquartile range (IQR) 3767-5598 µW/cm(2), median skin flap thickness 3.0 mm (IQR 2.7-3.3 mm)]. The output power strongly depended on implantation depth (ρSpearman = -0.86, P pacemaker powered by a 3.24 cm(2) solar module was implanted in vivo in a pig to measure output power and to pace. In vivo measurements showed a median output power of >3500 µW/cm(2) (skin flap thickness 2.8-3.84 mm). Successful batteryless VVI pacing using a subcutaneously implanted solar module was performed. Based on our results, we estimate that a few minutes of direct sunlight (irradiating an implanted solar module) allow powering a pacemaker for 24 h using a suitable energy storage. Thus, powering a pacemaker by sunlight is feasible and may be an alternative energy supply for tomorrow's pacemakers. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2014. For permissions please email: journals.permissions@oup.com.

  10. ARTERIAL HYPERTENSION AND MEDICAL SUPPORT OF PATIENTS WITH PERMANENT PACEMAKERS

    Directory of Open Access Journals (Sweden)

    T. A. Derienko

    2016-06-01

    Full Text Available The review is devoted to clinical problems of arterial hypertension (AH in patients with implanted pacemakers (EKS and cardiac resynchronization therapy (CRT. Indications for pacemaker implantation and CRT are considered, especially the purpose and effectiveness of angiotensin-converting enzyme (ACE inhibitors, angiotensin II receptor antagonists (ARA, sartans, beta-blockers (BAB, diuretics, calcium channel blockers. We prove that the CRT and cardiac pacing and do not cancel, bur modify drug therapy of AH.

  11. ARTERIAL HYPERTENSION AND MEDICAL SUPPORT OF PATIENTS WITH PERMANENT PACEMAKERS

    OpenAIRE

    T. A. Derienko

    2016-01-01

    The review is devoted to clinical problems of arterial hypertension (AH) in patients with implanted pacemakers (EKS) and cardiac resynchronization therapy (CRT). Indications for pacemaker implantation and CRT are considered, especially the purpose and effectiveness of angiotensin-converting enzyme (ACE) inhibitors, angiotensin II receptor antagonists (ARA, sartans), beta-blockers (BAB), diuretics, calcium channel blockers. We prove that the CRT and cardiac pacing and do not cancel, bur modify...

  12. Family environment patterns in families with bipolar children.

    Science.gov (United States)

    Belardinelli, Cecilia; Hatch, John P; Olvera, Rene L; Fonseca, Manoela; Caetano, Sheila C; Nicoletti, Mark; Pliszka, Steven; Soares, Jair C

    2008-04-01

    We studied the characteristics of family functioning in bipolar children and healthy comparison children. We hypothesized that the family environment of bipolar children would show greater levels of dysfunction as measured by the Family Environment Scale (FES). We compared the family functioning of 36 families that included a child with DSM-IV bipolar disorder versus 29 comparison families that included only healthy children. All subjects and their parents were assessed with the K-SADS-PL interview. The parents completed the FES to assess their current family functioning. Multivariate analysis of variance was used to compare the family environment of families with and without offspring with bipolar disorder. Parents of bipolar children reported lower levels of family cohesion (pconflict (pfamilies where a parent had a history of mood disorders compared to families where parents had no history of mood disorders. Length of illness in the affected child was inversely associated with family cohesion (r=-0.47, p=0.004). Due to the case-control design of the study, we cannot comment on the development of these family problems or attribute their cause specifically to child bipolar disorder. Families with bipolar children show dysfunctional patterns related to interpersonal interactions and personal growth. A distressed family environment should be addressed when treating children with bipolar disorder.

  13. Depression and Bipolar Support Alliance

    Science.gov (United States)

    Depression and Bipolar Support Alliance Crisis Hotline Information Coping with a Crisis Suicide Prevention Information Psychiatric Hospitalization ... sign-up Education info, training, events Mood Disorders Depression Bipolar Disorder Anxiety Screening Center Co-occurring Illnesses/ ...

  14. Bipolar Affective Disorder and Migraine

    Directory of Open Access Journals (Sweden)

    Birk Engmann

    2012-01-01

    Full Text Available This paper consists of a case history and an overview of the relationship, aetiology, and treatment of comorbid bipolar disorder migraine patients. A MEDLINE literature search was used. Terms for the search were bipolar disorder bipolar depression, mania, migraine, mood stabilizer. Bipolar disorder and migraine cooccur at a relatively high rate. Bipolar II patients seem to have a higher risk of comorbid migraine than bipolar I patients have. The literature on the common roots of migraine and bipolar disorder, including both genetic and neuropathological approaches, is broadly discussed. Moreover, bipolar disorder and migraine are often combined with a variety of other affective disorders, and, furthermore, behavioural factors also play a role in the origin and course of the diseases. Approach to treatment options is also difficult. Several papers point out possible remedies, for example, valproate, topiramate, which acts on both diseases, but no first-choice treatments have been agreed upon yet.

  15. Pacemaker implantation after catheter ablation for atrial fibrillation.

    Science.gov (United States)

    Deshmukh, Abhishek J; Yao, Xiaoxi; Schilz, Stephanie; Van Houten, Holly; Sangaralingham, Lindsey R; Asirvatham, Samuel J; Friedman, Paul A; Packer, Douglas L; Noseworthy, Peter A

    2016-01-01

    Sinus node dysfunction requiring pacemaker implantation is commonly associated with atrial fibrillation (AF), but may not be clinically apparent until restoration of sinus rhythm with ablation or cardioversion. We sought to determine frequency, time course, and predictors for pacemaker implantation after catheter ablation, and to compare the overall rates to a matched cardioversion cohort. We conducted a retrospective analysis using a large US commercial insurance database and identified 12,158 AF patients who underwent catheter ablation between January 1, 2005 and December 31, 2012. Over an average of 2.4 years of follow-up, 5.6 % of the patients underwent pacemaker implantation. Using the Cox proportional hazards models, we found that risk of risks of pacemaker implantation was associated with older age (50-64 and ≥65 versus pacemaker implantation between ablation patients and propensity score (PS)-matched cardioversion groups (3.5 versus. 4.1 % at 1 year and 8.8 versus 8.3 % at 5 years). Overall, pacemaker implantation occurs in about 1/28 patients within 1 year of catheter ablation. The overall implantation rate decreased between 2005 and 2012. Furthermore, the risk after ablation is similar to cardioversion, suggesting that patients require pacing due to a common underlying electrophysiologic substrate, rather than the ablation itself.

  16. A high current gain gate-controlled lateral bipolar junction transistor with 90 nm CMOS technology for future RF SoC applications

    Science.gov (United States)

    Chen, Shuo-Mao; Fang, Yean-Kuen; Yeh, Wen-Kuan; Lee, I. C.; Chiang, Yen-Ting

    2008-08-01

    A CMOS-compatible gate-controlled lateral BJT (GC-LBJT) was prepared with a conventional 90 nm CMOS technology for radio frequency system-on-chip (RF SoC) applications. The emitter injection efficiency and the doping profile in P-well were optimized by properly controlling source, drain, and well implants. Consequently, the GC-LBJT with a gate length of 0.15 μm can achieve a current gain over 2000 and 17/19 GHz for the fT/fmax, respectively, which are 1000%, 200%, and 60% improvements in current gain, fT and fmax, respectively as compared to the LBJT reported previously.

  17. Is sodium current present in human sinoatrial node cells?

    NARCIS (Netherlands)

    Verkerk, Arie O.; Wilders, Ronald; van Borren, Marcel M. G. J.; Tan, Hanno L.

    2009-01-01

    Pacemaker activity of the sinoatrial node has been studied extensively in various animal species, but is virtually unexplored in man. As such, it is unknown whether the fast sodium current (I-Na) plays a role in the pacemaker activity of the human sinoatrial node. Recently, we had the unique

  18. Depressive and bipolar disorders

    DEFF Research Database (Denmark)

    Kessing, Lars Vedel; Hansen, Hanne Vibe; Demyttenaere, Koen

    2005-01-01

    BACKGROUND: There is increasing evidence that attitudes and beliefs are important in predicting adherence to treatment and medication in depressive and bipolar disorders. However, these attitudes have received little study in patients whose disorders were sufficiently severe to require...... hospitalization. METHOD: The Antidepressant Compliance Questionnaire (ADCQ) was mailed to a large population of patients with depressive or bipolar disorder, representative of patients treated in hospital settings in Denmark. RESULTS: Of the 1005 recipients, 49.9% responded to the letter. A large proportion....... Moreover, their partners agreed on these negative views. Women had a more negative view of the doctor-patient relationship than men, and patients with a depressive disorder had a more negative view of antidepressants than patients with bipolar disorder. The number of psychiatric hospitalizations...

  19. Impact of Pacemaker Lead Characteristics on Pacemaker Related Infection and Heart Perforation: A Nationwide Population-Based Cohort Study.

    Directory of Open Access Journals (Sweden)

    Yu-Sheng Lin

    Full Text Available Several risk factors for pacemaker (PM related complications have been reported. However, no study has investigated the impact of lead characteristics on pacemaker-related complications.Patients who received a new pacemaker implant from January 1997 to December 2011 were selected from the Taiwan National Health Insurance Database. This population was grouped according to the pacemaker lead characteristics in terms of fixation and insulation. The impact of the characteristics of leads on early heart perforation was analyzed by multivariable logistic regression analysis, while the impact of the lead characteristics on early and late infection and late heart perforation over a three-year period were analyzed using Cox regression. This study included 36,104 patients with a mean age of 73.4±12.5 years. In terms of both early and late heart perforations, there were no significant differences between groups across the different types of fixation and insulations. In the multivariable Cox regression analysis, the pacemaker-related infection rate was significantly lower in the active fixation only group compared to either the both fixation (OR, 0.23; 95% CI, 0.07-0.80; P = 0.020 or the passive fixation group (OR, 0.26; 95% CI, 0.08-0.83; P = 0.023.There was no difference in heart perforation between active and passive fixation leads. Active fixation leads were associated with reduced risk of pacemaker-related infection.

  20. Impact of Pacemaker Lead Characteristics on Pacemaker Related Infection and Heart Perforation: A Nationwide Population-Based Cohort Study.

    Science.gov (United States)

    Lin, Yu-Sheng; Chen, Tien-Hsing; Hung, Sheng-Ping; Chen, Dong Yi; Mao, Chun-Tai; Tsai, Ming-Lung; Chang, Shih-Tai; Wang, Chun-Chieh; Wen, Ming-Shien; Chen, Mien-Cheng

    2015-01-01

    Several risk factors for pacemaker (PM) related complications have been reported. However, no study has investigated the impact of lead characteristics on pacemaker-related complications. Patients who received a new pacemaker implant from January 1997 to December 2011 were selected from the Taiwan National Health Insurance Database. This population was grouped according to the pacemaker lead characteristics in terms of fixation and insulation. The impact of the characteristics of leads on early heart perforation was analyzed by multivariable logistic regression analysis, while the impact of the lead characteristics on early and late infection and late heart perforation over a three-year period were analyzed using Cox regression. This study included 36,104 patients with a mean age of 73.4±12.5 years. In terms of both early and late heart perforations, there were no significant differences between groups across the different types of fixation and insulations. In the multivariable Cox regression analysis, the pacemaker-related infection rate was significantly lower in the active fixation only group compared to either the both fixation (OR, 0.23; 95% CI, 0.07-0.80; P = 0.020) or the passive fixation group (OR, 0.26; 95% CI, 0.08-0.83; P = 0.023). There was no difference in heart perforation between active and passive fixation leads. Active fixation leads were associated with reduced risk of pacemaker-related infection.

  1. Spanish Pacemaker Registry. Thirteenth Official Report of the Spanish Society of Cardiology Working Group on Cardiac Pacing (2015).

    Science.gov (United States)

    Pombo Jiménez, Marta; Cano Pérez, Óscar; Fidalgo Andrés, María Luisa; Lorente Carreño, Diego; Coma Samartín, Raúl

    2016-12-01

    We describe the results of the analysis of the devices implanted and conveyed to the Spanish Pacemaker Registry in 2015. The report is based on the processing of information provided by the European Pacemaker Patient Identification Card. We received information from 111 hospitals, with a total of 12 555 cards, representing 32.1% of all the estimated activity. The use of conventional generators and resynchronization devices was 820 and 73 units per million population, respectively. The mean age of the patients receiving an implantation was 77.7 years, and more than 50% of the devices were implanted in patients over 80 years of age. Overall, 58.6% of the implants and 58.8% of the replacements were performed in men. All of the endocardial leads employed were bipolar, 81.5% had an active fixation system, and 16.5% were compatible with magnetic resonance. Although dual chamber sequential pacing continues to be more widespread, pacing with VVI/R mode is used because up to 23.8% of the patients with sinus node disease are in sinus rhythm, as are 24.1% of those with atrioventricular block. The total use of pacemaker generators in Spain has increased by about 5% with respect to 2014. The majority of the leads implanted are of active fixation, and less than 20% are protected from magnetic resonance. The factors directly related to the selection of pacing mode are age and sex. In around 20% of patients, the choice of the pacing mode could be improved. Copyright © 2016 Sociedad Española de Cardiología. Published by Elsevier España, S.L.U. All rights reserved.

  2. Novel multiple criteria decision making methods based on bipolar neu trosophic sets and bipolar neutrosophic graphs

    OpenAIRE

    Muhammad Akram; Musavarah Sarwar

    2017-01-01

    In this research article, we present certain notions of bipolar neutrosophic graphs. We study the dominating and independent sets of bipolar neutrosophic graphs. We describe novel multiple criteria decision making methods based on bipolar neutrosophic sets and bipolar neutrosophic graphs.

  3. [Right heart failure after pacemaker implantation].

    Science.gov (United States)

    Gallego Galiana, Juan; López Castellanos, Genoveva; Gioia, Francesca; Ruiz Ortega, Raúl Antonio; Cobo Reinoso, Maria Eugenia; Manzano Espinosa, Luis

    2015-06-22

    Severe tricuspid regurgitation (TR) secondary to interference pacemaker (PM) cable is a rare cause of progressive right heart failure (HF), which can worsen patient outcomes. We present 3 clinical cases of right HF secondary to TR after PM implantation. In these patients the clinic is right HF, which can appear early, as in our second patient, or after years of implementation of the PM, as in the first and third patients. The diagnosis is confirmed by echocardiography, the most accurate 3D, followed by transesophageal. The 2D transthoracic can not detect it, because it has low sensitivity for TR associated with PM. Medical treatment is always the first choice, since any other procedure carries significant morbidity and mortality. Probably this is a condition that we will diagnose with increasing frequency, because there are more and more patients with devices and, at the same time, the diagnostic tools are improving. Copyright © 2015 Elsevier España, S.L.U. All rights reserved.

  4. Discrete bipolar universal integrals

    Czech Academy of Sciences Publication Activity Database

    Greco, S.; Mesiar, Radko; Rindone, F.

    2014-01-01

    Roč. 252, č. 1 (2014), s. 55-65 ISSN 0165-0114 R&D Projects: GA ČR GAP402/11/0378 Institutional support: RVO:67985556 Keywords : bipolar integral * universal integral * Choquet integral Subject RIV: BA - General Mathematics Impact factor: 1.986, year: 2014 http://library.utia.cas.cz/separaty/2014/E/mesiar-0432224.pdf

  5. Antidepressants for the acute treatment of bipolar depression: a systematic review and meta-analysis.

    Science.gov (United States)

    Sidor, Michelle M; Macqueen, Glenda M

    2011-02-01

    The role of antidepressants in the acute treatment of bipolar depression remains a contentious issue. A previous meta-analysis of randomized controlled trials (RCTs) concluded that antidepressants were effective and safe for bipolar depression. Several trials published since then suggest that antidepressants may not be as beneficial as previously concluded. The current systematic review and meta-analyses reexamine the efficacy and safety of antidepressant use for the acute treatment of bipolar depression. EMBASE, MEDLINE, CINAHL, PsycINFO, and the Cochrane Central Register of Controlled Trials databases were searched for double-blind RCTs published from 2003 to 2009 using the following diagnostic medical subject heading (MESH) terms: bipolar disorder, bipolar depression, bipolar I disorder, bipolar II disorder, bipolar III disorder, bipolar mania, cyclothymia, manic depressive psychosis, mixed mania and depression, and rapid cycling and bipolar disorder. Databases of trial registries were also searched for unpublished RCTs. These searches were supplemented by hand searches of relevant articles and review articles. Trials that compared acute (antidepressant treatment with either an active drug or a placebo comparator in adult bipolar patients, depressive phase were eligible for inclusion. Main outcome measures were clinical response, remission, and affective switch. Six RCTs (N = 1,034) were identified since publication in 2004 of the first meta-analysis that assessed antidepressant use in the acute treatment of bipolar depression. These studies were combined with earlier studies for a total of 15 studies containing 2,373 patients. Antidepressants were not statistically superior to placebo or other current standard treatment for bipolar depression. Antidepressants were not associated with an increased risk of switch. Studies that employed more sensitive criteria to define switch did report elevated switch rates for antidepressants. Although antidepressants were

  6. [Spouses and bipolar disorder].

    Science.gov (United States)

    Ellouze, F; Ayedi, S; Cherif, W; Ben Abla, T; M'rad, M F

    2011-02-01

    To assess the quality of life of a population of spouses of bipolar patients compared with a control population. We conducted a cross-sectional study which included two groups: a group of 30 spouses of patients followed for bipolar I disorder according to DSM IV criteria and a second group of 30 subjects from the general population. Both groups were matched by age, sex, marital status and socioeconomic level. This device was designed to limit the differences between the two groups solely those of the bipolar illness. Evaluating the quality of life was achieved using the quality of life scale: SF-36. This is a scale that has already been translated and validated in dialect Arabic. Regarding sociodemographic variables, the two study groups differed only for: recreation, friendly relations and the couple relationship that included more and better skills among the control group. In the categorical approach, the quality of life was impaired in 60% of spouses and 40% of controls with a statistically significant difference. The following standardized dimensions: mental health (D4), limitation due to mental health (D5), life and relationship with others (D6) and perceived health (D8) and mental component (CM) were significantly altered in patients' spouses compared to controls. We found significant differences between the two groups for: overall average score (51.1 vs. 68.2), mental health (D4), limitation due to mental health (D5), life and relationship with others (D6), perceived health (D8) and perceived health (D8) standards. The impairment of quality of life of bipolar patients' spouses is related to the extra responsibility, stress, financial problems and health problems, stigma, and loss of security of the person loved. Considering the consequences that the appearance of bipolar disorder on the patient's spouse may have, certain measures must be proposed to improve their quality of life. Copyright © 2010 L'Encéphale, Paris. Published by Elsevier Masson SAS. All

  7. Patients exposure from fluoroscopic guided pacemaker implantation procedures

    Energy Technology Data Exchange (ETDEWEB)

    Alkhorayef, M.; Babikir, E. [King Saud University, College of Applied Sciences, Radiological Sciences Department, P. O. Box 10219, Riyadh 11433 (Saudi Arabia); Sulieman, A. [Prince Sattam bin Abdulaziz University, College of Applied Medical Sciences, Radiology and Medical Imaging Department, P. O. Box 422, Alkharj 11942 (Saudi Arabia); Daar, E. [University of Jordan, Faculty of Science, Department of Physics, Amman 11942 (Jordan); Alnaaimi, M.; Alduaij, M. [Kuwait Cancer Control Centre, Department of Nuclear Medicine, Shwiekh (Kuwait); Bradley, D., E-mail: malkhorayef@ksu.edu.sa [University of Surrey, Centre for Nuclear and Radiation Physics, Guildford, Surrey, GU2 7XH (United Kingdom)

    2016-10-15

    A pacemaker, which is used for heart re synchronization with electrical impulses, is used to manage many clinical conditions. Recently, the frequency of the pacemaker implantation procedures increased 50% worldwide. During this procedure, patients and staff can be exposed to excessive radiation exposure. Wide range of doses was reported in previous studies, suggesting that optimization of this procedure is not fulfilled yet. This study aims to evaluate the patient and staff radiation doses during cardiac pacemaker procedure and quantify the patient effective dose. A total of 145 procedures were performed for five pacemakers procedures (VVI, VVIR, VVD, VVDR and DDDR) two hospitals were evaluated. Patients doses were measured using the kerma-area product meter. Effective doses were estimated using software based on Monte Carlo simulation from National Radiological Protection Board. The effective dose values were used to estimate the cancer risk from pacemaker procedure. Patients demographic data, exposure parameters for both fluoroscopy and radiography were quantified. The mean patients doses (Gy. cm{sup 2}) for VVI, VVIR, VVD, VVDR and DDDR was 1.52±0.13 (1.43-1.61), 3.28±2.34 (0.29-8.73), 3.04±1.67 (1.57-4.86), 6.04±2.326 and 19.2±3.6 (5.43-30.2), respectively, per procedure. The overall patients effective dose is 1.1 mSv per procedure. (Author)

  8. Implantable Cardiac Pacemakers – 50 Years from the First Implantation

    Directory of Open Access Journals (Sweden)

    Ratko Magjarević

    2010-01-01

    Overview: Development of implantable cardiac pacemaker was enabled by another important invention, the silicon transistor. h ough the invention of suitable lithium cells as appropriate power supply was essential for prolongation of battery life cycle and for increased reliability of pacemakers, main milestones in the development were associated with technological breakthroughs in electronics: from transistors, which introduced such features as small size and low power consumption, to hybrid and integrated circuits, which enabled programmability, microprocessors, which added more options in programming (multiprogrammability, diagnostics and telemetry, and the ICT (information communication technology that enabled physicians remote access to patients and interrogation of their implantable devices. Conclusions: Implantable pacemakers are reliable devices indicated for a wide range of dif erent therapies of cardiac rhythm disorders and heart failure. h ere is still a lot to learn about the physiology of a normal heart and even more about the failing heart. Modern pacemakers provide physicians valuable information from pacemakers’ memory via the built-in telemetry system. h ese information help physicians to better understand pathologic processes within the heart, thus contributing to the development of new ideas for treatment of diseases and for precise tailoring of the therapy to the patient’s needs. Although implantable pacemakers have reached the level of mature technology, they will continue to develop with therapies and diagnostics to facilitate a higher quality of life.

  9. Safety of Laser Interstitial Thermal Therapy in Patients With Pacemakers.

    Science.gov (United States)

    Grewal, Sanjeet S; Gorny, Krzysztof R; Favazza, Christopher P; Watson, Robert E; Kaufmann, Timothy J; Van Gompel, Jamie J

    2018-02-10

    Laser interstitial thermal therapy (LiTT) has increasingly been used as a treatment option for medically refractory epilepsy, tumors, and radiation necrosis. The use of LiTT requires intraoperative magnetic resonance (MR) thermography. This can become an issue in patients with other implanted therapeutic devices such as pacemakers and vagal nerve stimulators due to concerns regarding increases in the specific absorption rate (SAR). This is a technical case report demonstrating a successfully and safely performed LiTT in a 1.5-T magnetic resonance imaging (MRI) in a patient with a pacemaker for mesial temporal sclerosis. An 83-yr-old gentleman who had an implanted cardiac pacemaker presented with medically intractable epilepsy and was confirmed to have mesial temporal sclerosis on imaging. Video electroencephalography demonstrated concordant ipsilateral seizures and semiology. He underwent LiTT for ablation of the mesial temporal lobe. This was performed with the below described protocol with a cardiology nurse monitoring the patient's cardiac condition and a physicist monitoring SAR, and MR imaging quality without any adverse events. This study reports on a protocol of cardiac and MR SAR to safely perform MR-guided LiTT in the setting of traditional pacemakers in patients who are not pacemaker dependent. Copyright © 2018 by the Congress of Neurological Surgeons

  10. ON BIPOLAR SINGLE VALUED NEUTROSOPHIC GRAPHS

    OpenAIRE

    Broumi, Said; Talea, Mohamed; Bakali, Assia; Smarandache, Florentin

    2016-01-01

    In this article, we combine the concept of bipolar neutrosophic set and graph theory. We introduce the notions of bipolar single valued neutrosophic graphs, strong bipolar single valued neutrosophic graphs, complete bipolar single valued neutrosophic graphs, regular bipolar single valued neutrosophic graphs and investigate some of their related properties.

  11. Abordagens psicoterápicas no transtorno bipolar Psychoterapeutic approach in bipolar disorder

    Directory of Open Access Journals (Sweden)

    Paulo Knapp

    2005-01-01

    Full Text Available Embora o tratamento farmacológico seja essencial para o tratamento do transtorno bipolar, apenas 40% de todos os pacientes que aderem às medicações permanecem assintomáticos durante o período de seguimento, o que tem levado ao desenvolvimento de intervenções psicoterápicas associadas. O objetivo deste artigo é examinar as evidências atuais da eficácia de intervenções psicoterápicas no tratamento do transtorno bipolar. Foi realizada uma pesquisa bibliográfica por meio do MedLine, PsychoINFO, Lilacs e Cochrane Data Bank, até o ano de 2004, em que foram procurados artigos originais e revisões sobre as abordagens psicoterápicas utilizadas no tratamento do transtorno bipolar. Há várias abordagens que podem se mostrar úteis no tratamento do transtorno bipolar. A psicoeducação e a terapia cognitivo-comportamental apresentam as evidências mais consistentes e são as técnicas mais amplamente estudadas. As intervenções envolvendo familiares e a terapia interpessoal e de ritmo social se mostram tratamentos eficazes em determinadas situações. Há alguns estudos empregando a terapia psicodinâmica no transtorno bipolar, mas são estudos com limitações metodológicas. Apesar de haver evidências demonstrando a eficácia de determinadas abordagens psicoterápicas no transtorno bipolar, ainda é necessária a realização de estudos posteriores que comprovem tais dados e que desenvolvam tratamentos baseados em modelos etiológicos e que identifiquem tratamentos específicos para as diferentes fases e tipos de transtorno bipolar.Although pharmacological treatment is essential for treating bipolar disorder, less than half of all medication compliant patients are non-symptomatic during follow-up, which has led to developments of adjunctive psychosocial interventions. This paper examines the current evidence for effectiveness of psychotherapeutic interventions in the treatment of bipolar disorder. Searches were undertaken through Med

  12. Bipolar disorder and dementia: where is the link?

    Science.gov (United States)

    Masouy, Anaïs; Chopard, Gilles; Vandel, Pierre; Magnin, Eloi; Rumbach, Lucien; Sechter, Daniel; Haffen, Emmanuel

    2011-03-01

    Cognitive disorders appearing in the course of bipolar disease have been identified, and recent studies have defined the neuropsychological characteristics of this pathology, which includes attention, executive function, memory and language disorders. However, questions remain concerning the appearance of dementia symptoms over the course of bipolar disorder in certain patients: is it a chance association or is there a connection between bipolar disorders and dementia? If the latter hypothesis is considered, what is the nature of the dementia, which might be considered as a dementia specific to bipolar disorder? Current clinical, neuropsychological and cerebral imaging data are inconclusive, but similarities with frontotemporal dementia might be highlighted. Functional imaging studies might provide answers as well as more specific tests in neuropsychology. The cause of cognitive damage in bipolar disease also raises questions concerning a neurodevelopmental or neurodegenerative process, because several factors seem to influence cognition and these two processes might occur simultaneously. Long-term studies are necessary to determine whether cognitive deterioration in bipolar disease is stable or progressive. There might also be different neurobiological subgroups of patients with bipolar disease. © 2011 The Authors. Psychogeriatrics © 2011 Japanese Psychogeriatric Society.

  13. Contribution of small conductance K+ channels to sinoatrial node pacemaker activity: insights from atrial-specific Na+ /Ca2+ exchange knockout mice.

    Science.gov (United States)

    Torrente, Angelo G; Zhang, Rui; Wang, Heidi; Zaini, Audrey; Kim, Brian; Yue, Xin; Philipson, Kenneth D; Goldhaber, Joshua I

    2017-06-15

    Repolarizing currents through K + channels are essential for proper sinoatrial node (SAN) pacemaking, but the influence of intracellular Ca 2+ on repolarization in the SAN is uncertain. We identified all three isoforms of Ca 2+ -activated small conductance K + (SK) channels in the murine SAN. SK channel blockade slows repolarization and subsequent depolarization of SAN cells. In the atrial-specific Na + /Ca 2+ exchanger (NCX) knockout mouse, cellular Ca 2+ accumulation during spontaneous SAN pacemaker activity produces intermittent hyperactivation of SK channels, leading to arrhythmic pauses alternating with bursts of pacing. These findings suggest that Ca 2+ -sensitive SK channels can translate changes in cellular Ca 2+ into a repolarizing current capable of modulating pacemaking. SK channels are a potential pharmacological target for modulating SAN rate or treating SAN dysfunction, particularly under conditions characterized by abnormal increases in diastolic Ca 2+ . Small conductance K + (SK) channels have been implicated as modulators of spontaneous depolarization and electrical conduction that may be involved in cardiac arrhythmia. However, neither their presence nor their contribution to sinoatrial node (SAN) pacemaker activity has been investigated. Using quantitative PCR (q-PCR), immunostaining and patch clamp recordings of membrane current and voltage, we identified all three SK isoforms (SK1, SK2 and SK3) in mouse SAN. Inhibition of SK channels with the specific blocker apamin prolonged action potentials (APs) in isolated SAN cells. Apamin also slowed diastolic depolarization and reduced pacemaker rate in isolated SAN cells and intact tissue. We investigated whether the Ca 2+ -sensitive nature of SK channels could explain arrhythmic SAN pacemaker activity in the atrial-specific Na + /Ca 2+ exchange (NCX) knockout (KO) mouse, a model of cellular Ca 2+ overload. SAN cells isolated from the NCX KO exhibited higher SK current than wildtype (WT) and apamin

  14. [Pediatric bipolar disorder - case report of a bipolar patient with disease onset in childhood and adolescence: implications for diagnosis and therapy].

    Science.gov (United States)

    Lackner, N; Birner, A; Bengesser, S A; Reininghaus, B; Kapfhammer, H P; Reininghaus, E

    2014-11-01

    In recent years, intense controversies have evolved about the existence and exact diagnostic criteria of pediatric bipolar affective disorder. The present study aims to discuss pediatric bipolar affective disorder based on the current literature focussing on the diagnostic prospects. Based on a case study, a process of bipolar disorder developed in childhood is depicted exemplarily. Because of the high comorbidity and overlapping symptoms of paediatric bipolar affective disorder and other psychiatric disorders, the major impact of the differential diagnosis has to be stressed. An early diagnosis and the treatment possibilities are discussed. © Georg Thieme Verlag KG Stuttgart · New York.

  15. 77 FR 39924 - Effective Date of Requirement for Premarket Approval for Cardiovascular Permanent Pacemaker...

    Science.gov (United States)

    2012-07-06

    ... Approval for Cardiovascular Permanent Pacemaker Electrode AGENCY: Food and Drug Administration, HHS. ACTION... protocol (PDP) for the cardiovascular permanent pacemaker electrode. The Agency has summarized its findings... cardiovascular permanent pacemaker electrode. In accordance with section 515(b)(2)(A) of the FD&C Act, FDA...

  16. [TRENDS OF PERMANENT PACEMAKER IMPLANTATION IN A SINGLE CENTER OVER A 20-YEAR PERIOD].

    Science.gov (United States)

    Antonelli, Dante; Ilan, Limor Bushar; Freedberg, Nahum A; Feldman, Alexander; Turgeman, Yoav

    2015-05-01

    To review the changes in permanent pacemaker implantation indications, pacing modes and patients' demographics over a 20-year period. We retrospectively retrieved data on patients who underwent first implantation of the pacemaker between 1-1-1991 and 31-12-2010. One thousand and nine (1,009) patients underwent a first pacemaker implantation during that period; 535 were men (53%), their mean age was 74.6±19.5 years; the highest rate of implanted pacemaker was in patients ranging in age from 70-79 years, however there was an increasing number of patients aged over 80 years. The median survival time after initial pacemaker implantation was 8 years. Syncope was the most common symptom (62.5%) and atrioventricular block was the most common electrocardiographic indication (56.4%) leading to pacemaker implantation. There was increased utilization of dual chamber and rate responsive pacemakers over the years. There was no difference regarding mode selection between genders. Pacemaker implantation rates have increased over a 20-year period. Dual chamber replaced most of the single ventricular chamber pacemaker and rate responsive pacemakers became the norm. The data of a small volume center are similar to those reported in pacemaker surveys of high volume pacemaker implantation centers. They confirm adherence to the published guidelines for pacing.

  17. 77 FR 37570 - Effective Date of Requirement for Premarket Approval for a Pacemaker Programmer

    Science.gov (United States)

    2012-06-22

    ... Approval for a Pacemaker Programmer AGENCY: Food and Drug Administration, HHS. ACTION: Final rule. SUMMARY... approval application (PMA) or a notice of completion of a product development protocol (PDP) for pacemaker... for the pacemaker programmer (the August 2011 proposed rule). In accordance with section 515(b)(2)(A...

  18. [Study on Chaotic Detection Method of Pacemaker Contact-Less Power Supply].

    Science.gov (United States)

    Zhou, Chenghu; Huang, Mingming; Li, Songtao

    2015-12-01

    In order to improve the reliability of cardiac pacemaker contact-less power supply technology, this paper proposes a novel application of wireless feedback voltage stabilizing technology to adjust heart disease patients with inner power supply filter circuit output voltage and current control method, to keep the output voltage stability, and to ensure that the super capacitor and cardiac pacemaker to get a stable power supply. To implement the real-time accurate voltage control with considering the primary and secondary side inductance coupling coefficient changes, the change of the external power supply voltage and load, it is necessary to test thee real-time and accurate output voltage and current value after rectifying filtering. Therefore, based on the chaotic control theory, we adopted method of phase diagram on the basis of the quick observation after rectifying filtering, so that the method of voltage and current could improve the detection time of the circuit. The phase diagram of proposed control method can be divided into 8 segments, and we got 7 zero-extreme points. When these zero-extreme points are detected, according to extreme points of the zero instantaneous values, the corresponding average values of voltage and current were obtained. Simulation and experimental results showed that using the above method can shorten the response time to less than switch devices 1/2 switching cycles, thus validating the effectiveness and feasibility of the proposed detection algorithm.

  19. Radioisotope-powered cardiac pacemaker program. Clinical studies of the nuclear pacemaker model NU-5. Final report

    International Nuclear Information System (INIS)

    1980-06-01

    Beginning in February, 1970, the Nuclear Materials and Equipment Corporation (NUMEC) undertook a program to design, develop and manufacture a radioisotope powered cardiac pacemaker system. The scope of technical work was specified to be: establish system, component, and process cost reduction goals using the prototype Radioisotope Powered Cardiac Pacemaker (RCP) design and develop production techniques to achieve these cost reduction objectives; fabricate radioisotope powered fueled prototype cardiac pacemakers (RCP's) on a pilot production basis; conduct liaison with a Government-designated fueling facility for purposes of defining fueling requirements, fabrication and encapsulation procedures, safety design criteria and quality control and inspection requirements; develop and implement Quality Assurance and Reliability Programs; conduct performance, acceptance, lifetime and reliability tests of fueled RCP's in the laboratory; conduct liaison with the National Institutes of Health and with Government specified medical research institutions selected for the purpose of undertaking clinical evaluation of the RCP in humans; monitor and evaluate, on a continuing basis, all test data; and perform necessary safety analyses and tests. Pacemaker designs were developed and quality assurance and manufacturing procedures established. Prototype pacemakers were fabricated. A total of 126 radioisotope powered units were implanted and have been followed clinically for approximately seven years. Four (4) of these units have failed. Eighty-three (83) units remain implanted and satisfactorily operational. An overall failure rate of less than the target 0.15% per month has been achieved

  20. Pacemaker Placement in Patients with Stroke-Mediated Autonomic Dysregulation

    Directory of Open Access Journals (Sweden)

    Ali A. Alsaad

    2017-01-01

    Full Text Available Lateral medullary syndrome (LMS is an ischemic disease of the medulla oblongata, which involves the territory of the posterior inferior cerebellar artery. Lateral medullary syndrome is often missed as the cause of autonomic dysregulation in patients with recent brain stem stroke. Due to the location of the baroreceptor regulatory center in the lateral medulla oblongata, patients with LMS occasionally have autonomic dysregulation-associated clinical manifestations. We report a case of LMS-associated autonomic dysregulation. The case presented as sinus arrest and syncope, requiring permanent pacemaker placement. A dual-chamber pacemaker was placed, after failure of conservative measures to alleviate the patient’s symptoms. Our case shows the importance of recognizing LMS as a potential cause for life-threatening arrhythmias, heart block, and symptomatic bradycardia. Placement of permanent pacemaker may be necessary in some patients with LMS presenting with syncope, secondary to sinus arrest.

  1. Pacemaker patients' perception of unsafe activities: a survey

    Directory of Open Access Journals (Sweden)

    Shafquat Azam

    2008-11-01

    Full Text Available Abstract Background Cardiac pacing is a recognized and widely used treatment for patients presenting with bradycardia. Physicians expect patients to return to normal activities almost immediately post implantation. However, patients themselves may perceive interference to pacemaker function by various routine activities and devices, and hence continue to lead restricted, disabled lives. The aim of this study is to determine if routine activities are perceived by pacemaker patients to interfere with their device function. Methods A descriptive cross sectional survey was carried out on consecutive patients at the pacemaker clinic at a public hospital in Karachi, Pakistan. A 47-question tool was developed and tested. Patients' perceptions of safety of performing various routine activities, along with socio-demographic data were recorded. Results The final sample included 93 adult patients (45% males. 41% were illiterate. 77.4% recalled receiving counselling at implantation, predominantly from the implanting physician and house staff. A considerable proportion of patients considered many routine activities unsafe including driving automobiles (28%, passing through metal detectors (31%, bending over (37%, and sleeping on the side of the pacemaker (30%. Also considered unsafe were operation of household appliances- TV/VCR (television/video cassette recorders (53%, irons (55% and electrical wall switches (56%. For nearly all variables neither literacy nor history of counselling improved incorrect perceptions. Conclusion This study shows that our pacemaker patients perceive many routine activities as unsafe, potentially leading to disabling life style modifications. The tremendous investment in pacemaker technology to improve patient performance is not going to pay dividends if patients continue to remain disabled due to incorrect perceptions. Further studies are required to determine the reasons for these misperceptions, and to determine if these

  2. Outpatient diagnosis and clinical presentation of bipolar youth.

    Science.gov (United States)

    Saxena, Kirti; Nakonezny, Paul A; Simmons, Alex; Mayes, Taryn; Walley, Annie; Emslie, Graham

    2009-08-01

    Many children and adolescents in the community do not fit the classic Diagnostic and Statistical Manual of Mental Disorders (DSM-IV-TR) criteria for Bipolar Disorder, Type I., and bipolar disorder, not otherwise specified (BPNOS) is often the "catch all" diagnosis. Significant research has been conducted to better understand the phenomenology of the spectrum of bipolar disorder; however, there are presently different operational definitions for bipolar disorder, in both clinical and research settings. A recent study, The Course and Outcome of Bipolar Youth (COBY) provided preliminary validation for diagnosing BPNOS. Using these COBY research definitions for BPNOS, we examined the clinical presentation and the prior history of psychotropic medication usage of youth with BPI vs. BPNOS presenting to an outpatient clinic. The initial evaluation consisted of a direct clinical interview with the parent(s) and the patient. Standardized rating scales such as the Young Mania Rating Scale and the Quick Inventory of Depressive Symptoms were used to assess current mood states. The Clinical Global Impressions Scale-Severity was used to assess the overall functioning of bipolar youth. Age, comorbidities, and family histories of 68 bipolar youth in the clinic are similar to what other studies have reported. BPNOS youth have significant functional impairment which is comparable to the BPI youth. Both bipolar groups are equally likely to have similar prior exposure to psychotropic medications. BPNOS is a serious illness the diagnostic guidelines for which are still debatable. Until further clarification of this diagnosis, the COBY definitions for BPNOS can be used in a clinic. The use of stringent criteria for diagnosing the bipolar spectrum disorders allows for careful differential diagnoses of psychiatric illnesses.

  3. The Australian and New Zealand cardiac pacemaker and implantable cardioverter-defibrillator survey: calendar year 2013.

    Science.gov (United States)

    Mond, Harry G; Crozier, Ian

    2015-03-01

    A pacemaker (PM) and implantable cardioverter-defibrillator (ICD) survey was undertaken in Australia and New Zealand for calendar year 2013. For 2013, PMs sold as new implants in Australia was 15,203 (12,523 in 2009) and implanted in New Zealand were 1,641 (1,277 in 2009). The number of new PM implants per million population 652 for Australia (565 were in 2009) and 367 for New Zealand (299 in 2009). Although PM replacements rose in New Zealand, there was a fall in Australia as a result of improved power source service life. Pulse generator types sold in Australia were predominantly dual chamber 74% (71% in 2009) and implanted in New Zealand 59% (54% in 2009). There were 661 biventricular PMs implanted in Australia (446 in 2009) and 83 in New Zealand (45 in 2009). Transvenous pacing leads were overwhelmingly bipolar with preferences for active fixation leads, although, since 2009, there has been a minor resurgence in Australia of passive fixation lead usage in the atrium from 20 to ∼24%. There was also a marked increase in the ICD implants with 3904 new implants in Australia (3555 in 2009) and 423 in New Zealand (329 in 2009). The new ICD implants per million population were 167 for Australia (160 in 2009) and 95 for New Zealand (77 in 2009). Biventricular ICD implants increased significantly in both Australia (2211) and New Zealand (118). Published by Elsevier B.V.

  4. Life expectancy in bipolar disorder

    DEFF Research Database (Denmark)

    Kessing, Lars Vedel; Vradi, Eleni; Andersen, Per Kragh

    2015-01-01

    OBJECTIVE: Life expectancy in patients with bipolar disorder has been reported to be decreased by 11 to 20 years. These calculations are based on data for individuals at the age of 15 years. However, this may be misleading for patients with bipolar disorder in general as most patients have a later...... onset of illness. The aim of the present study was to calculate the remaining life expectancy for patients of different ages with a diagnosis of bipolar disorder. METHODS: Using nationwide registers of all inpatient and outpatient contacts to all psychiatric hospitals in Denmark from 1970 to 2012 we...... remaining life expectancy in bipolar disorder and that of the general population decreased with age, indicating that patients with bipolar disorder start losing life-years during early and mid-adulthood. CONCLUSIONS: Life expectancy in bipolar disorder is decreased substantially, but less so than previously...

  5. [Development and research of temporary demand pacemaker with electrocardiosignal display].

    Science.gov (United States)

    Fan, Shounian; Jiang, Chenxi; Cai, Yunchang; Pan, Yangzhong; Yang, Tianhe; Wu, Qiang; Zheng, Yaxi; Liu, Xiaoqiao; Li, Shiying

    2004-08-01

    A temporary demand pacemaker with electrocardiosignal display is introduced in this paper. Double way low-noise electrocardiosignal preamplifier, amplitude limiter, high and low pass filter, 50 Hz notch filter, TTL level generator and stimulating pulse formation circuit are components of the hardware electrocircuit. The demand pacing and the electrocardiosignal display are separately controlled by the software in which the double microcontrollers communications technique is used. In this study, liquid crystal display is firstly used in body surface electrocardiosignal display or intracardial electrophysiologic signal display when the temporary demand pacemaker is installed and put into use. The machine has proven clinically useful and can be of wide appliation.

  6. Interference with the pacemakers of two workers at electricity substations.

    Science.gov (United States)

    Butrous, G S; Bexton, R S; Barton, D G; Male, J C; Camm, A J

    1983-11-01

    Pacemaker function was tested in two electricity substation workers exposed to high tension electric fields. High intensity electric fields induced reversion to the interference mode, producing in one case competitive rhythm and in the other inappropriately slow pacing which resulted in asymptomatic pauses of up to 2.5 s. A suit designed to shield the body from the effects of high intensity electric fields was tried and proved to be effective in protecting the pacemaker, allowing it to function normally in the substations.

  7. Bipolar Disorder and Alcoholism: Are They Related?

    Science.gov (United States)

    ... Is there a connection between bipolar disorder and alcoholism? Answers from Daniel K. Hall-Flavin, M.D. Bipolar disorder and alcoholism often occur together. Although the association between bipolar ...

  8. Transcatheter leadless pacemaker implantation in a patient with a transvenous dual-chamber pacemaker already in place.

    Science.gov (United States)

    Karjalainen, Pasi P; Nammas, Wail; Paana, Tuomas

    2016-01-01

    An 83-year-old lady had a DDDR pacemaker inserted in 1997 for symptomatic atrioventricular block. She underwent battery replacement in 2008. In 2010, she developed atrial fibrillation; the pacemaker was switched to VVIR mode. During the last 2years, ventricular lead threshold increased progressively. In December 2015, she presented for elective battery replacement. After successful battery replacement, the ventricular lead threshold remained high; therefore, we implanted a leadless transcatheter pacemaker, via femoral vein access, using a dedicated catheter delivery system. Electrical measurements at this stage revealed a pacing threshold of 0.28V at 0.24msec, and an impedance of 650Ω. Copyright © 2016 Elsevier Inc. All rights reserved.

  9. [Creativity and bipolar disorder].

    Science.gov (United States)

    Maçkalı, Zeynep; Gülöksüz, Sinan; Oral, Timuçin

    2014-01-01

    The relationship between creativity and bipolar disorder has been an intriguing topic since ancient times. Early studies focused on describing characteristics of creative people. From the last quarter of the twentieth century, researchers began to focus on the relationship between mood disorders and creativity. Initially, the studies were based on biographical texts and the obtained results indicated a relationship between these two concepts. The limitations of the retrospective studies led the researchers to develop systematic investigations into this area. The systematic studies that have focused on artistic creativity have examined both the prevalence of mood disorders and the creative process. In addition, a group of researchers addressed the relationship in terms of affective temperaments. Through the end of the 90's, the scope of creativity was widened and the notion of everyday creativity was proposed. The emergence of this notion led researchers to investigate the associations of the creative process in ordinary (non-artist) individuals. In this review, the descriptions of creativity and creative process are mentioned. Also, the creative process is addressed with regards to bipolar disorder. Then, the relationship between creativity and bipolar disorder are evaluated in terms of aforementioned studies (biographical, systematic, psychobiographical, affective temperaments). In addition, a new model, the "Shared Vulnerability Model" which was developed to explain the relationship between creativity and psychopathology is introduced. Finally, the methodological limitations and the suggestions for resolving these limitations are included.

  10. International Society for Bipolar Disorders Task Force on Suicide

    DEFF Research Database (Denmark)

    Schaffer, Ayal; Isometsä, Erkki T; Tondo, Leonardo

    2015-01-01

    significantly associated with suicide attempts were: female gender, younger age at illness onset, depressive polarity of first illness episode, depressive polarity of current or most recent episode, comorbid anxiety disorder, any comorbid substance use disorder, alcohol use disorder, any illicit substance use......OBJECTIVES: Bipolar disorder is associated with a high risk of suicide attempts and suicide death. The main objective of the present study was to identify and quantify the demographic and clinical correlates of attempted and completed suicide in people with bipolar disorder. METHODS: Within...... the framework of the International Society for Bipolar Disorders Task Force on Suicide, a systematic review of articles published since 1980, characterized by the key terms bipolar disorder and 'suicide attempts' or 'suicide', was conducted, and data extracted for analysis from all eligible articles...

  11. Bipolar Disorder and Diabetes Mellitus

    Directory of Open Access Journals (Sweden)

    Sermin Kesebir

    2010-04-01

    Full Text Available Comorbid endocrine and cardiovascular situations with bipolar disorder usually result from the bipolar disorder itself or as a consequence of its treatment. With habits and lifestyle, genetic tendency and side effects, this situation is becoming more striking. Subpopulations of bipolar disorders patients should be considered at high risk for diabetes mellitus. The prevalence of diabetes mellitus in bipolar disorder may be three times greater than in the general population. Comorbidity of diabetes causes a pathophysiological overlapping in the neurobiological webs of bipolar cases. Signal mechanisms of glycocorticoid/insulin and immunoinflammatory effector systems are junction points that point out the pathophysiology between bipolar disorder and general medical cases susceptible to stress. Glycogen synthetase kinase (GSK-3 is a serine/treonine kinase and inhibits the transport of glucose stimulated by insulin. It is affected in diabetes, cancer, inflammation, Alzheimer disease and bipolar disorder. Hypoglycemic effect of lithium occurs via inhibiting glycogen synthetase kinase. When comorbid with diabetes, the other disease -for example bipolar disorder, especially during its acute manic episodes-, causes a serious situation that presents its influences for a lifetime. Choosing pharmacological treatment and treatment adherence are another important interrelated areas. The aim of this article is to discuss and review the etiological, clinical and therapeutic properties of diabetes mellitus and bipolar disorder comorbidity.

  12. 'A pacemaker in my heart' -- classification of questions asked by pacemaker patients as a basis for intervention.

    Science.gov (United States)

    Rassin, Michal; Zilcha, Lia; Gross, Dalia

    2009-01-01

    The research aimed to identify the information patients find necessary, following pacemaker implantation. Although pacemaker devices do not have an adverse impact on lifestyle, they evoke anxiety related to the patient's activities and lifestyle. Survey. A convenience sample of participants was taken from the entire population of patients who attended the cardiology clinic between January-June 2007; 274 individual meetings were held with 123 pacemaker patients in three periods, reflecting different stages of recovery. In the meeting, patients were invoked to ask any question they may have regarding pacemaker implantation. The questions were collected from the patients and categorised chronologically, in accordance with their frequency in three periods, reflecting different stages of recovery. Eight categories, representing common issues and content were raised: motion and effort, environmental influences, personal hygiene, knowledge concerning the pacemaker operation, medical treatment, eating and drinking, clothing and general questions. Findings show that the common factor for most of the questions was the loss of confidence in the various aspects of life. The largest relative question proportion was in the motion and effort (27%) (e.g. may I swim? how many kg may I lift?) and environmental influences (26%) (e.g. may I use a cellular phone? may I use a shaving machine?). A coherent, continuous pattern was found, characterising the different points of measurement where, at the first point, questions were characterised as more existential, related to daily routine activities and as time passed and patients were exposed to non-daily activities and conditions, other questions were raised. Pacemaker implant guidance should be based upon experimental evidence, arranged according to each category's relative weight and take into account the patient's point of view.

  13. An unusual case of pacemaker failure: complete disconnection of connector block and battery of a subpectorally implanted dual chamber pacemaker.

    Science.gov (United States)

    Mellert, Fritz; Esmailzadeh, Bahman; Schneider, Christian; Haushofer, Marcus; Schimpf, Rainer; Wolpert, Christian; Preusse, Claus J; Lüderitz, Berndt; Welz, Armin

    2002-04-01

    Local trauma to patients with implanted pacemaker devices may result in lead fracture or breakage of the lead socket with leakage of fluid into the connector system. This report describes an unusual case of complete entrance and exit block in a subpectorally implanted dual chamber pacemaker due to total disconnection and dislodgement of header block and battery part. Damage may be caused by an interaction of machine fatigue/manufacturing defective and fixation of the header with unusual movability of the battery, leading to breakage with intermittent malfunction and consecutive bradycardia and syncope.

  14. Methodological recommendations for cognition trials in bipolar disorder by the International Society for Bipolar Disorders Targeting Cognition Task Force

    DEFF Research Database (Denmark)

    Miskowiak, K W; Burdick, K E; Martinez-Aran, A

    2017-01-01

    OBJECTIVES: To aid the development of treatment for cognitive impairment in bipolar disorder, the International Society for Bipolar Disorders (ISBD) convened a task force to create a consensus-based guidance paper for the methodology and design of cognition trials in bipolar disorder. METHODS...... of treatments to illness stage and using a multimodal approach. CONCLUSIONS: This ISBD task force guidance paper provides the first consensus-based recommendations for cognition trials in bipolar disorder. Adherence to these recommendations will likely improve the sensitivity in detecting treatment efficacy...... or partly remitted patients. It is strongly encouraged that trials exclude patients with current substance or alcohol use disorders, neurological disease or unstable medical illness, and keep non-study medications stable. Additional methodological considerations include neuroimaging assessments, targeting...

  15. Pacemaker optimization guided by echocardiography in cardiac resynchronization therapy

    Directory of Open Access Journals (Sweden)

    Trifunović Danijela

    2009-01-01

    Full Text Available Introduction. Cardiac resynchronization therapy (CRT or biventricular pacing is a contemporary treatment in the management of advanced heart failure. Echocardiography plays an evolving and important role in patient selection for CRT, follow-up of acute and chronic CRT effects and optimization of device settings after biventricular pacemaker implantation. In this paper we illustrate usefulness of echocardiography for successful AV and VV timing optimization in patients with CRT. A review of up-to-date literature concerning rationale for AV and VV delay optimization, echocardiographic protocols and current recommendations for AV and VV optimization after CRT are also presented. Outline of Cases. The first case is of successful AV delay optimization guided by echocardiography in a patient with dilated cardiomyopathy treated with CRT is presented. Pulsed blood flow Doppler was used to detect mitral inflow while programming different duration of AV delay. The AV delay with optimal transmittal flow was established. The optimal mitral flow was the one with clearly defined E and A waves and maximal velocity time integral (VTI of the mitral flow. Improvement in clinical status and reverse left ventricle remodelling with improvement of ejection fraction was registered in our patient after a month. The second case presents a patient with heart failure caused by dilated cardiomyopathy; six months after CRT implantation the patient was still NYHA class III and with a significantly depressed left ventricular ejection fraction. Optimization of VV interval guided by echocardiography was undertaken measuring VTI of the left ventricular outflow tract (LVOT during programming of different VV intervals. The optimal VV interval was determined using a maximal LVOT VTI. A month after VV optimization our patient showed improvement in LV ejection fraction. Conclusion. Optimal management of patients treated with CRT integrate both clinical and echocardiographic follow

  16. Is bipolar disorder specifically associated with aggression?

    Science.gov (United States)

    Ballester, Javier; Goldstein, Tina; Goldstein, Benjamin; Obreja, Mihaela; Axelson, David; Monk, Kelly; Hickey, MaryBeth; Iyengar, Satish; Farchione, Tiffany; Kupfer, David J; Brent, David; Birmaher, Boris

    2012-01-01

    Objective Several studies have suggested that bipolar disorder (BP) in adults is associated with aggressive behaviors. However, most studies have only included inpatients and have not taken possible confounding factors into consideration. The goal of this study was to compare the prevalence of aggression in subjects with BP compared to subjects with other non-BP psychopathology and healthy controls. Methods Subjects with bipolar I disorder (BP-I) and bipolar II disorder (BP-II) (n = 255), non-BP psychopathology (n = 85), and healthy controls (n = 84) were recruited. Aggression was measured using the Aggression Questionnaire (AQ). Group comparisons were adjusted for demographic and clinical differences (e.g., comorbid disorders) and multiple comparisons. The effects of the subtype of BP, current versus past episode, polarity of current episode, psychosis, the presence of irritable mania/hypomania only, and pharmacological treatment were examined. Results Subjects with BP showed significantly higher total and subscale AQ scores (raw and T-scores) when compared with subjects with non-BP psychopathology and healthy controls. Exclusion of subjects with current mood episodes and those with common comorbid disorders yielded similar results. There were no effects of BP subtype, polarity of the current episode, irritable manic/hypomanic episodes only, or current use of pharmacological treatments. Independent of the severity of BP and polarity of the episode, those in a current mood episode showed significantly higher AQ scores than those not in a current mood episode. Subjects with current psychosis showed significantly higher total AQ score, hostility, and anger than those without current psychosis. Conclusions Subjects with BP display greater rates of anger and aggressive behaviors, especially during acute and psychotic episodes. Early identification and management of these behaviors is warranted. PMID:22548901

  17. Prophylactic antibiotic for pacemaker surgery: what is optimal ...

    African Journals Online (AJOL)

    One of them, a bed-ridden patient developed severe pocket infection necessitating explantation and replacement 3 weeks later. Conclusions: We noted with satisfaction that short regime of prophylactic parentral ceftriaxone is effective in preventing pacemaker infection and there is no need for the long regimen. Niger Med J.

  18. 238Pu sources for cardiac pacemakers. II. Control

    International Nuclear Information System (INIS)

    Pottier, R.; Merigot, S.

    1976-01-01

    The method and the apparatus used for thermal (power) and radioactive control of radioisotopic sources for pacemakers are briefly described. The cybernetic system is also presented, which assumes almost automatically the monitoring of control, mechanical and electronic works, data processing, the measurements and computations, and the works related to quality control [fr

  19. A pacemaker for asystole in breath-holding spells

    OpenAIRE

    Legge, Leah M; Kantoch, Michal J; Seshia, Shashi S; Soni, Reeni

    2002-01-01

    Two cases of young children with frequent severe breath-holding spells complicated by prolonged asystole and seizures are reported. A ventricular pacemaker was implanted in each child, and both have subsequently remained free of syncope, although they continue to exhibit breath-holding behaviour.

  20. Deactivation of Pacemaker: Ethical Approach or Managerial Failure?

    Directory of Open Access Journals (Sweden)

    Macková Marie

    2017-12-01

    Full Text Available The decision about the deactivation of a pacemaker must be the result of a multicriteria decision-making process where the legal, ethical and effectiveness aspects must be taken into account and delicately balanced, while also considering the risk of managerial failure. Academic as well as professional discussion is necessary because there is a whole range of question marks on this topic and all the aspects mentioned above. The aim of this paper is to contribute to the debate by presenting the views of Czech physicians about the possibility of deactivation of the pacemaker in patients in terminal states. Based on the results of our research, the following steps are recommended to enable the deactivation of pacemakers in the Czech environment. Before the patient’s own indication of pacemaker therapy, treatment should be discussed with the patient in detail, including complications and deactivation options. Czech ethical consultant services should be set up in Czech hospitals. And last but not least, they should take an opinion on this issue as well as the professional society.

  1. [Mid-dermal elastolysis after insertion of a pacemaker].

    Science.gov (United States)

    Kottler, D; Lefèvre, A; Balme, B; Martin-Bourret, V; Zaharia, D; Skowron, F

    2015-11-01

    Mid-dermal elastolysis (MDE) is a rare acquired disease of elastic tissue histologically characterized by focal loss of elastic fibres within the mid-dermis. While the mechanisms leading to MDE remain unknown, increased degradation of elastic fibres may be involved. Many factors potentially triggering such degradation have been suggested. A 58-year-old man consulted for an asymptomatic reticulated eruption that began in the area of a pacemaker implanted six weeks earlier. The eruption consisted of erythematous polycyclic and coalescing macules with a wrinkled centre. Histopathology with orcein staining revealed focal loss of elastic fibres in the superficial reticular dermis only. Hypersensitivity reaction to any components of the pacemaker was ruled out by means of allergy exploration. Laboratory investigations including autoimmunological and haematological factors were unremarkable. A diagnosis was made of a reticular variant of MDE following insertion of a pacemaker. We report the second case of MDE following the insertion of a pacemaker, which could have triggered an inflammatory response directed specifically towards the elastic fibres. Copyright © 2015 Elsevier Masson SAS. All rights reserved.

  2. A pacemaker for asystole in breath-holding spells

    Science.gov (United States)

    Legge, Leah M; Kantoch, Michal J; Seshia, Shashi S; Soni, Reeni

    2002-01-01

    Two cases of young children with frequent severe breath-holding spells complicated by prolonged asystole and seizures are reported. A ventricular pacemaker was implanted in each child, and both have subsequently remained free of syncope, although they continue to exhibit breath-holding behaviour. PMID:20046299

  3. Regulation of basal and reserve cardiac pacemaker function by interactions of cAMP mediated PKA-dependent Ca2+ cycling with surface membrane channels

    Science.gov (United States)

    Vinogradova, Tatiana M.; Lakatta, Edward G.

    2009-01-01

    Decades of intensive research of primary cardiac pacemaker, the sinoatrial node, have established potential roles of specific membrane channels in the generation of the diastolic depolarization, the major mechanism allowing sinoatrial node cells generate spontaneous beating. During the last three decades, multiple studies made either in the isolated sinoatrial node or sinoatrial node cells have demonstrated a pivotal role of Ca2+ and, specifically Ca2+-release from sarcoplasmic reticulum, for spontaneous beating of cardiac pacemaker. Recently, spontaneous, rhythmic local subsarcolemmal Ca2+ releases from ryanodine receptors during late half of the diastolic depolarization have been implicated as a vital factor in the generation of sinoatrial node cells spontaneous firing. Local Ca2+ releases are driven by a unique combination of high basal cAMP production by adenylyl cyclases, high basal cAMP degradation by phosphodiesterases and a high level of cAMP-mediated PKA-dependent phosphorylation. These local Ca2+ releases activate an inward Na+-Ca2+ exchange current which accelerates the terminal diastolic depolarization rate and, thus, controls the spontaneous pacemaker firing. Both the basal primary pacemaker beating rate and its modulation via β-adrenergic receptor stimulation appear to be critically dependent upon intact RyR function and local subsarcolemmal sarcoplasmic reticulum generated Ca2+ releases. This review aspires to integrate the traditional viewpoint that has emphasized the supremacy of the ensemble of surface membrane ion channels in spontaneous firing of the primary cardiac pacemaker, and these novel perspectives of cAMP-mediated PKA-dependent Ca2+ cycling in regulation of the heart pacemaker clock, both in the basal state and during β-adrenergic receptor stimulation. PMID:19573534

  4. Hemodynamic instability after pulmonary veins isolation in a patient with dual chamber pacemaker: The phantom injury of the ventricular lead.

    Science.gov (United States)

    Kiuchi, Márcio Galindo; Lobato, Guilherme Miglioli; Chen, Shaojie

    2017-06-01

    The standard treatment of sinus node dysfunction (SND) is the pacemaker implantation, and the ideal methodology for the management of atrial fibrillation (AF) is rhythm control, but this is sometimes very hard to accomplish. For such actions, complete isolation of all pulmonary veins (PVI) is currently widely accepted as the best endpoint. In this case, we report a female patient, 81 years old, with controlled hypertension, without coronary artery disease, bearer of bilateral knee replacement, and dual chamber pacemaker implanted 1.5 years ago owing to sinus node disease, presenting the following symptoms: presyncope episodes associated with sustained irregular palpitation tachycardia. The evaluation of the pacemaker-recorded episodes of atrial fibrillation, the echocardiogram-presented normal systolic function and measurements, as well as the resting myocardial scintigraphy and with drug use did not demonstrate ischemia and/or fibrosis. The patient was in use of valsartan 320 mg daily, amlodipine 10 mg daily, sotalol hydrochloride 120 mg 2 times daily, and dabigatran 110 mg 2 times daily. At the end of the PVI, the patient presented hemodynamic instability, with a decrease in heart rate to 30 bpm and invasive arterial blood pressure to 60/30 mmHg. The pericardial puncture was quickly carried out with the possibility of cardiac tamponade as the first hypothesis, but no pericardial effusion was found. Next, we detected acute capture loss from the ventricular pacemaker lead, unvarying with high voltage and pulse width, even with stable impedance, sense and keeping the same position visualized by fluoroscopy. And there was soon afterwards induction of sustained ventricular tachycardia degenerating to spontaneous ventricular fibrillation. Electrical cardioversion-defibrillation was performed with 200J, and the sinus rhythm was reestablished, but there was a dead short, and the pacemaker generator was burned and disabled. So, we can speculate that

  5. Myers Briggs Type Indicator and Tridimensional Personality Questionnaire differences between bipolar patients and unipolar depressed patients.

    Science.gov (United States)

    Janowsky, D S; Morter, S; Hong, L; Howe, L

    1999-12-01

    The current study was designed to compare personality differences between bipolar patients and unipolar depressed patients, as evaluated on the Myers Briggs Type Indicator (MBTI) and the Tridimensional Personality Questionnaire (TPQ). A group of bipolar and a group of unipolar depressed patients filled out the MBTI, the TPQ, the Beck Depression Inventory, and the CAGE questionnaire. The two groups were compared with each other as to responses on the above surveys, and subgroups of bipolar depressed and bipolar patients with manic symptoms were also compared. Bipolar patients were found to be significantly more extroverted (p = 0.004) and less judging (p = 0.007) on the MBTI. They were significantly more novelty seeking (p = 0.004) and less harm avoidant (p = 0.002) on the TPQ. Of the above differences, only the TPQ harm avoidance scale appeared strongly linked to the patients' level of depression. Significant differences in personality exist between bipolar disorder and unipolar depressed patients.

  6. The impact of bipolar depression.

    Science.gov (United States)

    Post, Robert M

    2005-01-01

    Bipolar disorder is a chronic, intermittent illness that is associated with high morbidity and mortality. In addition, patients with bipolar disorder often have comorbid psychiatric conditions (such as anxiety disorders, alcohol or substance abuse, and eating disorders) or medical disorders (such as obesity), which result in increased burden of illness for the patients, family members, and treating clinicians. Although bipolar disorder consists of recurring episodes of mania and depression, patients spend more time depressed than manic. Bipolar depression is associated with a greater risk of suicide and of impairment in work, social, or family life than mania. This health burden also results in direct and indirect economic costs to the individual and society at large. Bipolar depression is often undiagnosed or misdiagnosed as unipolar depression, resulting in incorrect or inadequate treatment. Available treatments for bipolar depression include medications such as lithium, selected anticonvulsants, and the atypical antipsychotics. Traditional antidepressants are not recommended as monotherapy for bipolar depression as they can induce switching to mania. Early and accurate diagnosis, aggressive management, and earlier prophylactic treatment regimens are needed to overcome the impact of depressive episodes in patients with bipolar disorder.

  7. Bipolar zinc/oxygen battery development

    Energy Technology Data Exchange (ETDEWEB)

    Mueller, S. [Paul Scherrer Inst. (PSI), Villigen (Switzerland); Schlatter, C. [Swiss Federal Inst. of Technology, Lausanne (Switzerland)

    1997-06-01

    A bipolar electrically rechargeable Zn/O{sub 2} battery has been developed. Reticulated copper foam served as substrate for the zinc deposit on the anodic side, and La{sub 0.6}Ca{sub 0.4}CoO{sub 3}-catalyzed bifunctional oxygen electrodes were used on the cathodic side of the cells. The 100 cm{sup 2} unit cell had an open circuit voltage of 1,4 V(O{sub 2}) in moderately alkaline electrolyte. The open circuit voltage and the peak power measured for a stack containing seven cells were ca. 10V and 90W, respectively. The current-potential behaviour was determined as a function of the number of bipolar cells, and the maximum discharge capacity was determined at different discharge rates. (author) 4 figs., 1 ref.

  8. Scientific attitudes towards bipolar disorders

    Directory of Open Access Journals (Sweden)

    Mohammad-Hossein Biglu

    2014-02-01

    Full Text Available Introduction: Bipolar disorder is a psychiatric condition that is also called manic-depressive disease. It causes unusual changes in mood, energy, activity levels, and the ability to carry out day-to-day tasks. In the present study, 3 sets of data were considered and analyzed: first, all papers categorized under Bipolar Disorders in Science Citation Index Expanded (SCI-E database through 2001-2011; second, papers published by the international journal of Bipolar Disorders indexed in SCI-E during a period of 11 years; and third, all papers distributed by the international journal of Bipolar Disorders indexed in MEDLINE during the period of study. Methods: The SCI-E database was used to extract all papers indexed with the topic of Bipolar Disorders as well as all papers published by The International Journal of Bipolar Disorders. Extraction of data from MEDLINE was restricted to the journals name from setting menu. The Science of Science Tool was used to map the co-authorship network of papers published by The International Journal of Bipolar Disorders through 2009-2011. Results: Analysis of data showed that the majority of publications in the subject area of bipolar disorders indexed in SCI-E were published by The International Journal of Bipolar Disorders. Although journal articles consisted of 59% of the total publication type in SCI-E, 65% of publications distributed by The Journal of Bipolar Disorders were in the form of meetingabstracts. Journal articles consisted of only 23% of the total publications. USA was the leading country regarding sharing data in the field of bipolar disorders followed by England, Canada, and Germany. Conclusion: The editorial policy of The International Journal of Bipolar Disorders has been focused on new themes and new ways of researching in the subject area of bipolar disorder. Regarding the selection of papers for indexing, the SCI-E database selects data more comprehensively than MEDLINE. The number of papers

  9. Generation of metal composition gradients by means of bipolar electrodeposition

    International Nuclear Information System (INIS)

    Tisserant, Gwendoline; Fattah, Zahra; Ayela, Cédric; Roche, Jérome; Plano, Bernard; Zigah, Dodzi; Goudeau, Bertrand; Kuhn, Alexander; Bouffier, Laurent

    2015-01-01

    Highlights: • A bipolar electrochemistry approach for the preparation of surface gradients is reported. • Several metals are simultaneously deposited on a bipolar electrode. • The elemental composition and thickness of the deposit varies alongside the bipolar electrode. • The deposit affects the surface properties and exhibits a barcode feature. - Abstract: Bipolar electrochemistry is an unconventional technique that currently encounters a renewal of interest due to modern applications in the fields of analytical chemistry or materials science. The approach is particularly relevant for the preparation of asymmetric objects or surfaces such as Janus particles for example. Bipolar electrochemistry allows spatially controlled deposition of various layers from electroactive precursors, selectively at one side of a bipolar electrode. We report here the concomitant cathodic deposition of up to three different metals at the same time in a single experiment. The deposits were characterized by optical and electron microscopy imaging as well as profilometry and energy dispersive X-ray spectroscopy. As a result, the deposited layer is composed of several areas exhibiting both a composition and a thickness gradient. Such a variation directly modifies the optical and electronic properties alongside the surface and gives access to the design of composite surfaces exhibiting a visual gradient feature.

  10. Aberrant cerebellar connectivity in bipolar disorder with psychosis.

    Science.gov (United States)

    Shinn, Ann K; Roh, Youkyung S; Ravichandran, Caitlin T; Baker, Justin T; Öngür, Dost; Cohen, Bruce M

    2017-07-01

    The cerebellum, which modulates affect and cognition in addition to motor functions, may contribute substantially to the pathophysiology of mood and psychotic disorders, such as bipolar disorder. A growing literature points to cerebellar abnormalities in bipolar disorder. However, no studies have investigated the topographic representations of resting state cerebellar networks in bipolar disorder, specifically their functional connectivity to cerebral cortical networks. Using a well-defined cerebral cortical parcellation scheme as functional connectivity seeds, we compared ten cerebellar resting state networks in 49 patients with bipolar disorder and a lifetime history of psychotic features and 55 healthy control participants matched for age, sex, and image signal-to-noise ratio. Patients with psychotic bipolar disorder showed reduced cerebro-cerebellar functional connectivity in somatomotor A, ventral attention, salience, and frontoparietal control A and B networks relative to healthy control participants. These findings were not significantly correlated with current symptoms. Patients with psychotic bipolar disorder showed evidence of cerebro-cerebellar dysconnectivity in selective networks. These disease-related changes were substantial and not explained by medication exposure or substance use. Therefore, they may be mechanistically relevant to the underlying susceptibility to mood dysregulation and psychosis. Cerebellar mechanisms deserve further exploration in psychiatric conditions, and this study's findings may have value in guiding future studies on pathophysiology and treatment of mood and psychotic disorders, in particular.

  11. Computer modeling of electrical and thermal performance during bipolar pulsed radiofrequency for pain relief

    Energy Technology Data Exchange (ETDEWEB)

    Pérez, Juan J. [Instituto de Investigación Interuniversitario en Bioingeniería y Tecnología Orientada al Ser Humano, Universitat Politècnica de València, Valencia 46022 (Spain); Pérez-Cajaraville, Juan J. [Pain Unit and Department of Anesthesia and Critical Care, Clínica Universidad de Navarra, University of Navarra, Pamplona 31008 (Spain); Muñoz, Víctor [Neurotherm Spain, Barcelona 08303 (Spain); Berjano, Enrique, E-mail: eberjano@eln.upv.es [Biomedical Synergy, Electronic Engineering Department, Universitat Politècnica de València 46022 (Spain)

    2014-07-15

    Purpose: Pulsed RF (PRF) is a nonablative technique for treating neuropathic pain. Bipolar PRF application is currently aimed at creating a “strip lesion” to connect the electrode tips; however, the electrical and thermal performance during bipolar PRF is currently unknown. The objective of this paper was to study the temperature and electric field distributions during bipolar PRF. Methods: The authors developed computer models to study temperature and electric field distributions during bipolar PRF and to assess the possible ablative thermal effect caused by the accumulated temperature spikes, along with any possible electroporation effects caused by the electrical field. The authors also modeled the bipolar ablative mode, known as bipolar Continuous Radiofrequency (CRF), in order to compare both techniques. Results: There were important differences between CRF and PRF in terms of electrical and thermal performance. In bipolar CRF: (1) the initial temperature of the tissue impacts on temperature progress and hence on the thermal lesion dimension; and (2) at 37 °C, 6-min of bipolar CRF creates a strip thermal lesion between the electrodes when these are separated by a distance of up to 20 mm. In bipolar PRF: (1) an interelectrode distance shorter than 5 mm produces thermal damage (i.e., ablative effect) in the intervening tissue after 6 min of bipolar RF; and (2) the possible electroporation effect (electric fields higher than 150 kV m{sup −1}) would be exclusively circumscribed to a very small zone of tissue around the electrode tip. Conclusions: The results suggest that (1) the clinical parameters considered to be suitable for bipolar CRF should not necessarily be considered valid for bipolar PRF, and vice versa; and (2) the ablative effect of the CRF mode is mainly due to its much greater level of delivered energy than is the case in PRF, and therefore at same applied energy levels, CRF, and PRF are expected to result in same outcomes in terms of

  12. Novel multiple criteria decision making methods based on bipolar neutrosophic sets and bipolar neutrosophic graphs

    OpenAIRE

    Muhammad, Akram; Musavarah, Sarwar

    2016-01-01

    In this research study, we introduce the concept of bipolar neutrosophic graphs. We present the dominating and independent sets of bipolar neutrosophic graphs. We describe novel multiple criteria decision making methods based on bipolar neutrosophic sets and bipolar neutrosophic graphs. We also develop an algorithm for computing domination in bipolar neutrosophic graphs.

  13. Parasitic bipolar amplification in a single event transient and its temperature dependence

    International Nuclear Information System (INIS)

    Liu Zheng; Chen Shu-Ming; Chen Jian-Jun; Qin Jun-Rui; Liu Rong-Rong

    2012-01-01

    Using three-dimensional technology computer-aided design (TCAD) simulation, parasitic bipolar amplification in a single event transient (SET) current of a single transistor and its temperature dependence are studied. We quantify the contributions of different current components in a SET current pulse, and it is found that the proportion of parasitic bipolar amplification in total collected charge is about 30% in both 130-nm and 90-nm technologies. The temperature dependence of parasitic bipolar amplification and the mechanism of the SET pulse are also investigated and quantified. The results show that the proportion of charge induced by parasitic bipolar increases with rising temperature, which illustrates that the parasitic bipolar amplification plays an important role in the charge collection of a single transistor

  14. An actigraphy study investigating sleep in bipolar I patients, unaffected siblings and controls

    NARCIS (Netherlands)

    Verkooijen, Sanne; van Bergen, Annet H.; Knapen, Stefan E.; Vreeker, Annabel; Abramovic, Lucija; Pagani, Lucia; Jung, Yoon; Riemersma-van der Lek, Rixt; Schoevers, Robert A.; Takahashi, Joseph S.; Kahn, René S.; Boks, Marco P.M.; Ophoff, Roel A.

    2017-01-01

    Objectives Disturbances in sleep and waking patterns are highly prevalent during mood episodes in bipolar disorder. The question remains whether these disturbances persist during phases of euthymia and whether they are heritable traits of bipolar disorder. The current study investigates objective

  15. An actigraphy study investigating sleep in bipolar I patients, unaffected siblings and controls

    NARCIS (Netherlands)

    Verkooijen, Sanne; van Bergen, Annet H.; Knapen, Stefan E.; Vreeker, Annabel; Abramovic, Lucija; Pagani, Lucia; Jung, Yoon; Riemersma-van der Lek, Rixt; Schoevers, Robert A.; Takahashi, Joseph S.; Kahn, Rene S.; Boks, Marco P. M.; Ophoff, Roel A.

    2017-01-01

    Objectives: Disturbances in sleep and waking patterns are highly prevalent during mood episodes in bipolar disorder. The question remains whether these disturbances persist during phases of euthymia and whether they are heritable traits of bipolar disorder. The current study investigates objective

  16. Transdiagnostic Treatment of Bipolar Disorder and Comorbid Anxiety with the Unified Protocol: A Clinical Replication Series

    Science.gov (United States)

    Ellard, Kristen K.; Deckersbach, Thilo; Sylvia, Louisa G.; Nierenberg, Andrew A.; Barlow, David H.

    2012-01-01

    Bipolar disorder (BD) is a chronic, debilitating disorder with recurrent manic and depressive episodes. More than 75% of bipolar patients have a current or lifetime diagnosis of a comorbid anxiety disorder. Comorbid anxiety in BD is associated with greater illness severity, greater functional impairment, and poorer illness-related outcomes.…

  17. Bipolar pulse forming line

    Science.gov (United States)

    Rhodes, Mark A.

    2008-10-21

    A bipolar pulse forming transmission line module for linear induction accelerators having first, second, third, fourth, and fifth planar conductors which form an interleaved stack with dielectric layers between the conductors. Each conductor has a first end, and a second end adjacent an acceleration axis. The first and second planar conductors are connected to each other at the second ends, the fourth and fifth planar conductors are connected to each other at the second ends, and the first and fifth planar conductors are connected to each other at the first ends via a shorting plate adjacent the first ends. The third planar conductor is electrically connectable to a high voltage source, and an internal switch functions to short a high voltage from the first end of the third planar conductor to the first end of the fourth planar conductor to produce a bipolar pulse at the acceleration axis with a zero net time integral. Improved access to the switch is enabled by an aperture through the shorting plate and the proximity of the aperture to the switch.

  18. Tritium separation from light and heavy water by bipolar electrolysis

    International Nuclear Information System (INIS)

    Ramey, D.W.; Petek, M.; Taylor, R.D.; Kobisk, E.H.; Ramey, J.; Sampson, C.A.

    1979-10-01

    Use of bipolar electrolysis with countercurrent electrolyte flow to separate hydrogen isotopes was investigated for the removal of tritium from light water effluents or from heavy water moderator. Deuterium-tritium and protium-tritium separation factors occurring on a Pd-25% Ag bipolar electrode were measured to be 2.05 to 2.16 and 11.6 to 12.4 respectively, at current densities between 0.21 and 0.50 A cm -2 , and at 35 to 90 0 C. Current densities up to 0.3 A cm -2 have been achieved in continuous operation, at 80 to 90 0 C, without significant gas formation on the bipolar electrodes. From the measured overvoltage at the bipolar electrodes and the electrolyte conductivity the power consumption per stage was calculated to be 3.0 kwh/kg H 2 O at 0.2 A cm -2 and 5.0 kwh/kg H 2 O at 0.5 A cm -2 current density, compared to 6.4 and 8.0 kwh/kg H 2 O for normal electrolysis. A mathematical model derived for hydrogen isotope separation by bipolar electrolysis, i.e., for a square cascade, accurately describes the results for protium-tritium separation in two laboratory scale, multistage experiments with countercurrent electrolyte flow; the measured tiritum concentration gradient through the cascade agreed with the calculated values

  19. Conceptual design of GaN betavoltaic battery using in cardiac pacemaker

    International Nuclear Information System (INIS)

    Mohamadian, M.; Feghhi, S.A. H.; Afarideh, H.

    2007-01-01

    Introduction: Pacemaker is an electronic biomedical device which stimulates and regulates or amplify the human heartbeat by delivering weak electrical pulses to the cardiac muscle at regular intervals when its natural regulating mechanisms break down. Developments in design and implementation of power source in adjacent to advances in electronic circuitry is an important aspect in optimization of pacemakers. For instance, many implant patients continue to outlive their batteries and require costly and risky replacement surgery. So such device needs to have high energy density power source and maintain a stable current and voltage for a long period of time to avoid frequent replacements. In addition, the size is also an important consideration for implantable batteries. Betavoltaic batteries are being researched as a suitable source for these applications. Also, these batteries have vast application in which the replacement of batteries is highly inconvenient, such as in oil and mining industries, which often place sensors in dangerous or hard-to-reach locations. The purpose of the present investigation is determination of the optimal parameters of low energy GaN betavoltaic battery in artificial cardiac pacemakers using MCNP code which have higher efficiency than those available with previous devices, especially thermoelectric converters (∼15%). Material and Methods: In this design, two p-n diode structures from GaN semiconductor were used to collect the charge from a layer of 6 3Ni as a source which is centered between the two p-n junctions. MCNP simulation results have been used to determine the amount of electron current from interaction of beta particles in p-n junctions. Results and Discussion: Calculation results indicate that the short circuit current, open circuit voltage and efficiency of a single device are 1.1 μA/cm 2 , 2.7 volt and 25%, respectively. Also, it's concluded that with suitable arrangement of these single devices, one could construct a

  20. Asenapine for bipolar disorder

    Directory of Open Access Journals (Sweden)

    Scheidemantel T

    2015-12-01

    Full Text Available Thomas Scheidemantel,1 Irina Korobkova,2 Soham Rej,3,4 Martha Sajatovic1,2 1University Hospitals Case Medical Center, 2Case Western Reserve University School of Medicine, Cleveland, OH, USA; 3Department of Psychiatry, University of Toronto, Toronto, ON, 4Geri PARTy Research Group, Jewish General Hospital, Montreal, QC, Canada Abstract: Asenapine (Saphris® is an atypical antipsychotic drug which has been approved by the US Food and Drug Administration for the treatment of schizophrenia in adults, as well as the treatment of acute manic or mixed episodes of bipolar I in both adult and pediatric populations. Asenapine is a tetracyclic drug with antidopaminergic and antiserotonergic activity with a unique sublingual route of administration. In this review, we examine and summarize the available literature on the safety, efficacy, and tolerability of asenapine in the treatment of bipolar disorder (BD. Data from randomized, double-blind trials comparing asenapine to placebo or olanzapine in the treatment of acute manic or mixed episodes showed asenapine to be an effective monotherapy treatment in clinical settings; asenapine outperformed placebo and showed noninferior performance to olanzapine based on improvement in the Young Mania Rating Scale scores. There are limited data available on the use of asenapine in the treatment of depressive symptoms of BD, or in the maintenance phase of BD. The available data are inconclusive, suggesting the need for more robust data from prospective trials in these clinical domains. The most commonly reported adverse effect associated with use of asenapine is somnolence. However, the somnolence associated with asenapine use did not cause significant rates of discontinuation. While asenapine was associated with weight gain when compared to placebo, it appeared to be modest when compared to other atypical antipsychotics, and its propensity to cause increases in hemoglobin A1c or serum lipid levels appeared to be

  1. Subjective consequences of permanent pacemaker therapy in patients under the age of retirement

    DEFF Research Database (Denmark)

    Mickley, H; Petersen, J; Nielsen, B L

    1989-01-01

    During a 5-year period, 81 patients ages 20 to 60 years old had implantation of a permanent cardiac pacemaker at the University Hospital, Odense. At follow-up, during 1985, the 73 survivors received a semi-structured questionnaire regarding subjective consequences of pacemaker therapy, and 72...... people (98.6%) agreed to participate. The mean pacing period (range) was 33.8 (11-72) months. Surgical intervention was required in 14 patients (19.4%) during follow-up. Regarding all symptoms 67 patients (93.1%) perceived benefit from the pacemaker. The effectiveness of cardiac pacing was most...... or a sensation of "impulses"/palpitations. To the majority (49 patients or 68.1%) pacemaker treatment did not influence quality of sexual activity. Six patients (8.3%) perceived an improvement, whereas a corresponding number felt deterioration in sexual activity following pacemaker implantation. Pacemaker...

  2. [Use of a temporal cardiac pacemaker in patients undergoing a major non-cardiac surgery].

    Science.gov (United States)

    Robles González, L; Vázquez Cabrales, A; Chiw Castillo, G; Sánchez Ibarra, J H; Pérez Redondo, H

    1978-01-01

    This is a report of the use of transvenous temporal pacemaker in 18 patients, with an average age of 59.3 years, that under want non cardiac major surgery. They did not have cardiac simptoms but had conduction abnormalities in the preoperative electrocardiogram. A pacemaker was implanted as a prophylaxis against arrythmia during the transoperative and postoperative periods. There was no incidence of transoperative arrythmia. Three patients died in the immediate postoperative period, two due to duffuse carcinomatosis and one due to diabetic acidosis. The average duration of the implanted pacemaker was 12.7 days, and three patients required a permanent pacemaker. Case five is exemplificative of the benefits of the temporal pacemaker, he had a preoperative electrocardiogram showing trifascicular block, he was taken to the operating room and anesthesia was induced, the patient had a cardiac arrest but recovered without secuela; latter on a temporal pacemaker was inserted and the patient had surgery without cardiac problems.

  3. Complex regional pain syndrome type I following pacemaker implantation

    Directory of Open Access Journals (Sweden)

    Sangita Kamath

    2015-12-01

    Full Text Available A 70-year-old woman presented with burning pain and swelling over dorsum of right hand and small joints of the fingers, associated with redness, feeling of warmth, and stiffness of the fingers, with inability to bend the fingers since 2 months. The symptoms were progressively increasing in intensity for the past 1 month. There was no history of fever or trauma to the hand. Two months before her symptoms started, she had permanent pacemaker implanted for complete heart block with syncope. She was hypertensive and was on regular medication. Her X-ray of right hand showed decreased bone density (demineralisation, suggestive of osteopenia. A diagnosis of reflex sympathetic dystrophy syndrome or complex regional pain syndrome type I induced by pacemaker insertion was made. She was treated with amitriptyline and steroids, after which her symptoms improved dramatically.

  4. Transient apical dyskinesia with a pacemaker: Electrocardiographic features.

    Science.gov (United States)

    Núñez-Gil, Iván J; Feltes, Gisela I; Mejía-Rentería, Hernán D; Biagioni, Corina; De Agustín, J Alberto; Vivas, David; Fernández-Ortiz, Antonio

    2015-04-01

    Transient apical dyskinesia syndromes present features similar to acute coronary syndromes, but with normal coronary arteries and rapid complete resolution of wall motion alterations. We report the case of a 73-year-old woman who was admitted to hospital because of typical chest pain at rest after her brother's death. She had had a pacemaker implanted in 2001. Troponin levels were elevated and apical hypokinesia was shown by ventriculography and echocardiography, with normal coronary arteries. Evolving ECG alterations were observed in spite of the continued pacing rhythm. All these alterations were fully resolved after discharge. This case shows that, even in the presence of a pacemaker, evolving ECG alterations can be observed in Takotsubo syndrome. Copyright © 2014 Sociedade Portuguesa de Cardiologia. Published by Elsevier España. All rights reserved.

  5. A brief review of exercise, bipolar disorder, and mechanistic pathways

    Science.gov (United States)

    Thomson, Daniel; Turner, Alyna; Lauder, Sue; Gigler, Margaret E.; Berk, Lesley; Singh, Ajeet B.; Pasco, Julie A.; Berk, Michael; Sylvia, Louisa

    2015-01-01

    Despite evidence that exercise has been found to be effective in the treatment of depression, it is unclear whether these data can be extrapolated to bipolar disorder. Available evidence for bipolar disorder is scant, with no existing randomized controlled trials having tested the impact of exercise on depressive, manic or hypomanic symptomatology. Although exercise is often recommended in bipolar disorder, this is based on extrapolation from the unipolar literature, theory and clinical expertise and not empirical evidence. In addition, there are currently no available empirical data on program variables, with practical implications on frequency, intensity and type of exercise derived from unipolar depression studies. The aim of the current paper is to explore the relationship between exercise and bipolar disorder and potential mechanistic pathways. Given the high rate of medical co-morbidities experienced by people with bipolar disorder, it is possible that exercise is a potentially useful and important intervention with regard to general health benefits; however, further research is required to elucidate the impact of exercise on mood symptomology. PMID:25788889

  6. A brief review of exercise, bipolar disorder and mechanistic pathways

    Directory of Open Access Journals (Sweden)

    Daniel eThomson

    2015-03-01

    Full Text Available Despite evidence that exercise has been found to be effective in the treatment of depression, it is unclear whether these data can be extrapolated to bipolar disorder. Available evidence for bipolar disorder is scant, with no existing randomised controlled trials having tested the impact of exercise on depressive, manic or hypomanic symptomatology. Although exercise is often recommended in bipolar disorder, this is based on extrapolation from the unipolar literature, theory and clinical expertise and not empirical evidence. In addition, there are currently no available empirical data on program variables, with practical implications on frequency, intensity and type of exercise derived from unipolar depression studies. The aim of the current paper is to explore the relationship between exercise and bipolar disorder and potential mechanistic pathways. Given the high rate of medical co-morbidities experienced by people with bipolar disorder, it is possible that exercise is a potentially useful and important intervention with regard to general health benefits; however, further research is required to elucidate the impact of exercise on mood symptomology.

  7. Leadless pacemaker extraction from a single-center perspective.

    Science.gov (United States)

    González Villegas, Elkin; Al Razzo, Omar; Silvestre García, Jorge; Mesa García, José

    2018-02-01

    Leadless pacemaker can be considered as a technical revolution in cardiac pacing devices, with clear advantages over conventional pacemakers in overcoming all lead-related complications. However, the management of these devices once they reach the end of life (EOL) of the battery is still controversial. In the next years, there will be an increase in the need to define a clear strategy in the management of leadless PM once they reach their EOL. Safe extraction of these devices will define in a great manner this strategy METHODS: We performed the extraction of three functioning Nanostim leadless pacemaker prophylactically in two females and one male patients as part of the Nanostim battery depletion field action recommendation. All patients had a prior transesophageal 3D echocardiography to determine the device intracardiac mobility and the extent of possible endothelialization. For the extractions, we used the Nanostim Retrieval Catheter S1RSIN (St. Jude Medical, St. Paul, MN, USA), which is a proprietary catheter provided by the manufacturing company based on a lasso. Complete extraction of the devices was achieved in all patients using a relatively short fluoroscopic time (16, 19, and 12 minutes). The extraction of leadless pacemakers can be considered as a safe and feasible procedure using the tools provided by the manufacturer and designed for the extraction. However, a very low threshold must be maintained to avoid any risk to the patients. Our extraction time ranges are between 983 and 1,070 days, nevertheless it is necessary to gather more long-term data to assess the feasibility and safety of these procedures. © 2017 Wiley Periodicals, Inc.

  8. Plethyzmography in assessment of hemodynamic results of pacemaker functions programming

    Science.gov (United States)

    Wojciechowski, Dariusz; Sionek, Piotr; Peczalski, Kazimierz; Janusek, Dariusz

    2011-01-01

    The paper presents potential role of plethyzmography in optimization of heart hemodynamic function during pacemaker programming. The assessment of optimal stroke volume in patients, with implanted dual chamber pacemaker (DDD), by plethyzmography was a goal of the study. The data were collected during pacing rhythm. 20 patients (8 female and 12 male, average 77.4+/-4.6 years) with dual chamber pacemaker (DDD) and with pacing rhythm during routine pacemaker control and study tests were incorporated in the study group. Hemodynamic parameters were assessed during modification of atrio-ventricular delay (AVD) for pacing rhythm of 70 bpm and 90 bpm. The time of atrioventricular was programmed with 20 ms steps within range 100-200 ms and data were recorded with two minutes delay between two consecutive measurements. Stroke volume (SV) and cardiac output (CO) were calculated from plethyzmographic signal by using Beatscope software (TNO Holand). Highest SV calculated for given pacing rhythm was named optimal stroke volume (OSV) and consequently highest cardiac output was named maximal cardiac output (MCO). The time of atrio-ventricular delay for OSV was named optimal atrioventricular delay (OAVD). The results have showed: mean values of OAVD for 70 bpm - 152+/-33 ms and for 90 bpm -149+/-35 ms, shortening of the mean OAVD time caused by increase of pacing rate from 70 bpm to 90 bpm what resulted in statistically significant decrease of OSV with not statistically significant increase of MCO. The analysis of consecutive patients revealed three types of response to increase of pacing rhythm: 1. typical-shortening of OAVD, 2. neutral-no change of OAVD and 3.atypical-lengthening of OAVD.

  9. Identification and functional characterization of cardiac pacemaker cells in zebrafish.

    Directory of Open Access Journals (Sweden)

    Federico Tessadori

    Full Text Available In the mammalian heart a conduction system of nodes and conducting cells generates and transduces the electrical signals evoking myocardial contractions. Specialized pacemaker cells initiating and controlling cardiac contraction rhythmicity are localized in an anatomically identifiable structure of myocardial origin, the sinus node. We previously showed that in mammalian embryos sinus node cells originate from cardiac progenitors expressing the transcription factors T-box transcription factor 3 (Tbx3 and Islet-1 (Isl1. Although cardiac development and function are strikingly conserved amongst animal classes, in lower vertebrates neither structural nor molecular distinguishable components of a conduction system have been identified, questioning its evolutionary origin. Here we show that zebrafish embryos lacking the LIM/homeodomain-containing transcription factor Isl1 display heart rate defects related to pacemaker dysfunction. Moreover, 3D reconstructions of gene expression patterns in the embryonic and adult zebrafish heart led us to uncover a previously unidentified, Isl1-positive and Tbx2b-positive region in the myocardium at the junction of the sinus venosus and atrium. Through their long interconnecting cellular protrusions the identified Isl1-positive cells form a ring-shaped structure. In vivo labeling of the Isl1-positive cells by transgenic technology allowed their isolation and electrophysiological characterization, revealing their unique pacemaker activity. In conclusion we demonstrate that Isl1-expressing cells, organized as a ring-shaped structure around the venous pole, hold the pacemaker function in the adult zebrafish heart. We have thereby identified an evolutionary conserved, structural and molecular distinguishable component of the cardiac conduction system in a lower vertebrate.

  10. Modeling the dual pacemaker system of the tau mutant hamster.

    Science.gov (United States)

    Oda, G A; Menaker, M; Friesen, W O

    2000-06-01

    Circadian pacemakers in many animals are compound. In rodents, a two-oscillator model of the pacemaker composed of an evening (E) and a morning (M) oscillator has been proposed based on the phenomenon of "splitting" and bimodal activity peaks. The authors describe computer simulations of the pacemaker in tau mutant hamsters viewed as a system of mutually coupled E and M oscillators. These mutant animals exhibit normal type 1 PRCs when released into DD but make a transition to a type 0 PRC when held for many weeks in DD. The two-oscillator model describes particularly well some recent behavioral experiments on these hamsters. The authors sought to determine the relationships between oscillator amplitude, period, PRC, and activity duration through computer simulations. Two complementary approaches proved useful for analyzing weakly coupled oscillator systems. The authors adopted a "distinct oscillators" view when considering the component E and M oscillators and a "system" view when considering the system as a whole. For strongly coupled systems, only the system view is appropriate. The simulations lead the authors to two primary conjectures: (1) the total amplitude of the pacemaker system in tau mutant hamsters is less than in the wild-type animals, and (2) the coupling between the unit E and M oscillators is weakened during continuous exposure of hamsters to DD. As coupling strength decreases, activity duration (alpha) increases due to a greater phase difference between E and M. At the same time, the total amplitude of the system decreases, causing an increase in observable PRC amplitudes. Reduced coupling also increases the relative autonomy of the unit oscillators. The relatively autonomous phase shifts of E and M oscillators can account for both immediate compression and expansion of activity bands in tau mutant and wild-type hamsters subjected to light pulses.

  11. Involvement of MAPKs and PLC Pathways in Modulation of Pacemaking Activity by So-Cheong-Ryong-Tang in Interstitial Cells of Cajal from Murine Small Intestine

    Directory of Open Access Journals (Sweden)

    Min Woo Hwang

    2013-01-01

    Full Text Available Purpose. Interstitial cells of Cajal (ICCs are the pacemaker cells that generate slow waves in the gastrointestinal (GI tract. We have aimed to investigate the effects of Socheongryong-Tang (SCRT in ICCs from mouse’s small intestine. Methods. The whole-cell patch-clamp configuration was used to record membrane potentials from cultured ICCs. Intracellular Ca2+ ([Ca2+]i increase was studied in cultured ICCs using fura-2 AM. Results. ICCs generated pacemaker potentials in mouse’s small intestine. SCRT produced membrane depolarization in current clamp mode. Y25130 (5-HT3 receptor antagonist and RS39604 (5-HT4 receptor antagonist blocked SCRT-induced membrane depolarizations, whereas SB269970 (5-HT7 receptor antagonist did not. When GDP-β-S (1 mM was in the pipette solution, SCRT did not induce the membrane depolarizations. [Ca2+]i analysis showed that SCRT increased [Ca2+]i. In the presence of PD98059 (p42/44 MAPK inhibitor, SCRT did not produce membrane depolarizations. In addition, SB203580 (p38 MAPK inhibitor and JNK inhibitors blocked the depolarizations by SCRT in pacemaker potentials. Furthermore, the membrane depolarizations by SCRT were not inhibited by U-73122, an active phospholipase C (PLC inhibitor, but by U-73343, an inactive PLC inhibitor. Conclusion. These results suggest that SCRT might affect GI motility by the modulation of pacemaker activity through MAPKs and PLC pathways in the ICCs.

  12. Modulation of Pacemaker Potentials by Pyungwi-San in Interstitial Cells of Cajal from Murine Small Intestine - Pyungwi-San and Interstitial Cells of Cajal -

    Directory of Open Access Journals (Sweden)

    Kim Jung Nam

    2013-03-01

    Full Text Available Objective: Pyungwi-san (PWS plays a role in a number of physiologic and pharmacologic functions in many organs. Interstitial cells of Cajal (ICCs are pacemaker cells that generate slow waves in the gastrointestinal (GI tract. We aimed to investigate the beneficial effects of PWS in mouse small-intestinal ICCs. Methods: Enzymatic digestion was used to dissociate ICCs from the small intestine of a mouse. The wholecell patch-clamp configuration was used to record membrane potentials from the cultured ICCs. Results: ICCs generated pacemaker potentials in the GI tract. PWS produced membrane depolarization in the current clamp mode. Pretreatment with a Ca2+-free solution and a thapsigargin, a Ca2+-ATPase, inhibitor in the endoplasmic reticulum, eliminated the generation of pacemaker potentials. However, only when the thapsigargin was applied in a bath solution, the membrane depolarization was not produced by PWS. Furthermore, the membrane depolarizations due to PWS were inhibited not by U-73122, an active phospholipase C inhibitor, but by chelerythrine and calphostin C, protein kinase C inhibitors. Conclusions: These results suggest that PWS might affect GI motility by modulating the pacemaker activity in the ICCs.

  13. Brain magnetic resonance imaging examination in a patient with non-magnetic resonance conditional pacemaker

    Directory of Open Access Journals (Sweden)

    Toshiko Nakai, MD

    2017-10-01

    Full Text Available Clinical dilemmas arise when patients with a non-magnetic resonance (MR conditional pacemaker are required to undergo magnetic resonance imaging (MRI. We encountered a pacemaker patient with debilitating non-motor symptoms of Parkinson׳s disease, who required an MRI prior to deep brain stimulation (DBS surgery. MRI was performed safely without adverse events despite the presence of a conventional pacemaker.

  14. Indirect bipolar electrodeposition.

    Science.gov (United States)

    Loget, Gabriel; Roche, Jérome; Gianessi, Eugenio; Bouffier, Laurent; Kuhn, Alexander

    2012-12-12

    Based on the principles of bipolar electrochemistry, localized pH gradients are generated at the surface of conducting particles in solution. This allows the toposelective deposition of inorganic and organic polymer layers via a pH-triggered precipitation mechanism. Due to the intrinsic symmetry breaking of the process, the concept can be used to generate in a straightforward way Janus particles, with one section consisting of deposits obtained from non-electroactive precursors. These indirect electrodeposits, such as SiO(2), TiO(2), or electrophoretic paints, can be further used as an immobilization matrix for other species like dyes or nanoparticles, thus opening promising perspectives for the synthesis of a variety of bifunctional objects with a controlled shape.

  15. Hypersexuality and couple relationships in bipolar disorder: A review.

    Science.gov (United States)

    Kopeykina, Irina; Kim, Hae-Joon; Khatun, Tasnia; Boland, Jennifer; Haeri, Sophia; Cohen, Lisa J; Galynker, Igor I

    2016-05-01

    with comorbid substance use as well as inpatient, outpatient, symptomatic and euthymic patients, may limit the generalizability of results. Although bipolar patients experience disease-specific sexual problems of mania-induced hypersexuality and specific effects of mood cycling on couple relationships, the existing literature is mostly outdated and lacks a consistent definition of hypersexuality. Novel research is needed to address sexual symptomatology in bipolar disorder within the context of current sexual, cultural and gender norms. Copyright © 2016. Published by Elsevier B.V.

  16. Physiological effects of light on the human circadian pacemaker

    Science.gov (United States)

    Shanahan, T. L.; Czeisler, C. A.

    2000-01-01

    The physiology of the human circadian pacemaker and its influence and on the daily organization of sleep, endocrine and behavioral processes is an emerging interest in science and medicine. Understanding the development, organization and fundamental properties underlying the circadian timing system may provide insight for the application of circadian principles to the practice of clinical medicine, both diagnostically (interpretation of certain clinical tests are dependent on time of day) and therapeutically (certain pharmacological responses vary with the time of day). The light-dark cycle is the most powerful external influence acting upon the human circadian pacemaker. It has been shown that timed exposure to light can both synchronize and reset the phase of the circadian pacemaker in a predictable manner. The emergence of detectable circadian rhythmicity in the neonatal period is under investigation (as described elsewhere in this issue). Therefore, the pattern of light exposure provided in the neonatal intensive care setting has implications. One recent study identified differences in both amount of sleep time and weight gain in infants maintained in a neonatal intensive care environment that controlled the light-dark cycle. Unfortunately, neither circadian phase nor the time of day has been considered in most clinical investigations. Further studies with knowledge of principles characterizing the human circadian timing system, which governs a wide array of physiological processes, are required to integrate these findings with the practice of clinical medicine.

  17. Percutaneous Extraction of Transvenous Permanent Pacemaker/Defibrillator Leads

    Directory of Open Access Journals (Sweden)

    Stylianos Paraskevaidis

    2014-01-01

    Full Text Available Background. Widespread use of cardiovascular implantable electronic devices has inevitably increased the need for lead revision/replacement. We report our experience in percutaneous extraction of transvenous permanent pacemaker/defibrillator leads. Methods. Thirty-six patients admitted to our centre from September 2005 through October 2012 for percutaneous lead extraction were included. Lead removal was attempted using Spectranetics traction-type system (Spectranetics Corp., Colorado, CO, USA and VascoExtor countertraction-type system (Vascomed GmbH, Weil am Rhein, Germany. Results. Lead extraction was attempted in 59 leads from 36 patients (27 men, mean ± SD age 61±5 years, with permanent pacemaker (n=25, defibrillator (n=8, or cardiac resynchronisation therapy (n=3 with a mean ± SD implant duration of 50±23 months. The indications for lead removal included pocket infection (n=23, endocarditis (n=2, and ventricular (n=10 and atrial lead dysfunction (n=1. Traction device was used for 33 leads and countertraction device for 26 leads. Mean ± SD fluoroscopy time was 4±2 minutes/lead for leads implanted 48 months (n=21, P=0.03. Complete procedural success rate was 91.7% and clinical procedural success rate was 100%, while lead procedural success rate was 95%. Conclusions. In conclusion, percutaneous extraction of transvenous permanent pacemaker/defibrillator leads using dedicated removal tools is both feasible and safe.

  18. Minimally invasive resynchronization pacemaker: a pediatric animal model.

    Science.gov (United States)

    Jordan, Christopher P; Wu, Kyle; Costello, John P; Ishibashi, Nobuyuki; Krieger, Axel; Kane, Timothy D; Kim, Peter; Berul, Charles I

    2013-12-01

    We developed a minimally invasive epicardial pacemaker implantation method for infants and congenital heart disease patients for whom a transvenous approach is contraindicated. The piglet is an ideal model for technical development. In 5 piglets we introduced a needle through subxiphoid approach under thoracoscopic guidance, inserting a wire into the pericardial space. Pacing leads were affixed to the left ventricular free wall and left atrial appendage. After verifying functionality with atrial and ventricular pacing and sensing, animals were euthanized. Pacemaker monitoring occurred daily for 4 days in the fifth animal. Through minimally invasive pericardial access, we directly visualized and fixated pacing leads to the left ventricle and left atrial appendage, successfully pacing atrium and ventricle. Epicardial structures were visualized. One piglet had contralateral pneumothorax, which resolved with needle decompression. No other adverse events occurred. Minimally invasive epicardial pacemaker implantation in an infant model is feasible and effective. This innovation may be of value for pacing and resynchronization in infants and congenital heart disease patients. Survival studies with permanent generator implantation are under way. Copyright © 2013 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  19. A Systematic Review of Economic Evaluations of Pacemaker Telemonitoring Systems.

    Science.gov (United States)

    López-Villegas, Antonio; Catalán-Matamoros, Daniel; Martín-Saborido, Carlos; Villegas-Tripiana, Irene; Robles-Musso, Emilio

    2016-02-01

    Over the last decade, telemedicine applied to pacemaker monitoring has undergone extraordinary growth. It is not known if telemonitoring is more or less efficient than conventional monitoring. The aim of this study was to carry out a systematic review analyzing the available evidence on resource use and health outcomes in both follow-up modalities. We searched 11 databases and included studies published up until November 2014. The inclusion criteria were: a) experimental or observational design; b) studies based on complete economic evaluations; c) patients with pacemakers, and d) telemonitoring compared with conventional hospital monitoring. Seven studies met the inclusion criteria, providing information on 2852 patients, with a mean age of 81 years. The main indication for device implantation was atrioventricular block. With telemonitoring, cardiovascular events were detected and treated 2 months earlier than with conventional monitoring, thus reducing length of hospital stay by 34% and reducing routine and emergency hospital visits as well. There were no significant intergroup differences in perceived quality of life or number of adverse events. The cost of telemonitoring was 60% lower than that of conventional hospital monitoring. Compared with conventional monitoring, cardiovascular events were detected earlier and the number or hospitalizations and hospital visits was reduced with pacemaker telemonitoring. In addition, the costs associated with follow-up were lower with telemonitoring. Copyright © 2015 Sociedad Española de Cardiología. Published by Elsevier España, S.L.U. All rights reserved.

  20. Pacemaker lead perforation of the right ventricle associated with Moraxella phenylpyruvica infection in a dog.

    Science.gov (United States)

    Ciavarella, A; Nimmo, J; Hambrook, L

    2016-04-01

    A 13-year-old neutered male Border Collie was presented with acute onset syncope, weakness and anorexia 10 months after transvenous pacemaker implantation. The patient was laterally recumbent, bradycardic (36 beats/min) and febrile (40.7°C) on presentation. An electrocardiogram (ECG) revealed recurrence of third-degree atrioventricular block with a ventricular escape rhythm. Fluoroscopy identified migration of the pacemaker tip through the apex of the right ventricle. Echocardiography failed to reveal any evidence of pericardial effusion or cardiac tamponade. Full postmortem was performed after euthanasia. The pacemaker lead had perforated the apex of the right ventricle and lodged in the right pleural space. Culture of blood (taken antemortem), pericardial sac, right ventricular wall (surrounding pacemaker lead), pacemaker lead tip and pericardial fluid revealed a pure growth of Moraxella phenylpyruvica. Bacteraemia associated with M. phenylpyruvica has never been reported in the dog, but sporadic cases are reported in humans. Infection could have resulted from either pre-existing myocarditis or opportunistic infection and bacteraemia post pacemaker implantation. Evaluation of the pacemaker function at regular intervals would allow early detection of poor pacemaker-to-myocardium contact, which would prompt further investigation of pacemaker lead abnormalities such as perforation. © 2016 Australian Veterinary Association.

  1. Interference of cardiac pacemaker and implantable cardioverter-defibrillator activity during electronic dental device use.

    Science.gov (United States)

    Roedig, Jason J; Shah, Jignesh; Elayi, Claude Samy; Miller, Craig S

    2010-05-01

    The authors conducted a study to determine if electromagnetic interference of cardiac pacemaker and implantable cardioverter-defibrillator (ICD) activity occurs during the operation of electronic dental devices. The authors tested nine electronic dental devices in vitro to assess their ability to interfere with the function of two pacemakers and two ICDs as determined by electrocardiographic telemetry. The pacing activity of both pacemakers and the dual-chamber ICD were inhibited during operation of the battery-operated composite curing light at between 2 and 10 centimeters from the generator or leads. The use of the ultrasonic scaler interfered with the pacing activity of the dual-chamber pacemaker at between 17 and 23 cm from the generator or leads, the single-chamber pacemaker at 15 cm from the generator or leads and both ICDs at 7 cm from the leads. The operation of the ultrasonic cleaning system interfered with the activity of the dual-chamber pacemaker at between 15 and 23 cm from the generator or leads, and of the single-chamber pacemaker at 12 cm. Operation of the electric toothbrush, electrosurgical unit, electric pulp tester, high- and low-speed handpieces, and an amalgamator did not alter pacing function. Select electronic dental devices interfere with pacemakers' and ICDs' sensing and pacing activity in vitro. Use of the ultrasonic scaler, ultrasonic cleaning system and battery-operated composite curing light may produce deleterious effects in patients who have pacemakers or ICDs.

  2. Successful Interventional Management for Pulmonary Arterial Injury Secondary to Pacemaker Implantation

    Directory of Open Access Journals (Sweden)

    Hiroyuki Tokue

    2016-01-01

    Full Text Available Subclavian vein puncture is a relatively fast and safe technique to access the right heart for placement of pacemaker leads. Hemothorax related to injury of the pulmonary artery (PA is a rare complication of subclavian vein access but can be life-threatening. We report a case of hemothorax occurring after subclavian vein puncture for pacemaker implantation. No cases of transcatheter arterial embolization for PA injury secondary to pacemaker implantation have been reported. Understanding of this rare complication after pacemaker implantation along with its specific clinical presentation may lead to early diagnosis and intervention.

  3. Multiple photoreceptor systems control the swim pacemaker activity in box jellyfish

    DEFF Research Database (Denmark)

    Garm, Anders Lydik; Mori, S.

    2009-01-01

    Like all other cnidarian medusae, box jellyfish propel themselves through the water by contracting their bell-shaped body in discrete swim pulses. These pulses are controlled by a swim pacemaker system situated in their sensory structures, the rhopalia. Each medusa has four rhopalia each...... with a similar set of six eyes of four morphologically different types. We have examined how each of the four eye types influences the swim pacemaker. Multiple photoreceptor systems, three of the four eye types, plus the rhopalial neuropil, affect the swim pacemaker. The lower lens eye inhibits the pacemaker...

  4. [Psychoeducation and interpersonal and social rhythm therapy for bipolar disorder].

    Science.gov (United States)

    Mizushima, Hiroko

    2011-01-01

    In treating bipolar disorder, specific psychotherapies in adjunct to pharmacotherapy have been shown to be effective in preventing new episodes and treating depressive episodes. Among those, interpersonal and social rhythm therapy (IPSRT) developed by Frank, amalgamation of interpersonal psychotherapy (IPT) with behavioral therapy focused on social rhythm has been shown to be an efficacious adjunct to mediation in preventing new episodes in bipolar I patients and in treating depression in bipolar I arid II disorder. IPSRT has also been shown to enhance total functioning, relationship functioning and life satisfaction among patients with bipolar disorder, even after pretreatment functioning and concurrent depression were covaried. IPSRT was designed to directly address the major pathways to recurrence in bipolar disorder, namely medication nonadherence, stressful life events, and disruptions in social rhythms. IPT, originated by Klerman et al., is a strategic time-limited psychotherapy focused on one or two of four current interpersonal problem areas (ie, grief, interpersonal role disputes, role transitions, and interpersonal dificits). In IPSRT, the fifth problem area "grief for the lost healthy self" has been added in order to promote acceptance of the diagnosis and the need for life-long treatment. Social rhythm therapy is a behavioral approach aiming at increasing regularity of social rhythms using the Social Rhythm Metric (SRM), a chart to record daily social activities including how stimulating they were, developed from observation that disruptions in social rhythms often trigger affective episodes in patients with bipolar disorder. IPSRT also appears to be a promising intervention for a subset of individuals with bipolar II depression as monotherapy for the acute treatment.

  5. Basic Principles of Interpersonal Social Rhythm Therapy in Bipolar Disorder

    Directory of Open Access Journals (Sweden)

    Gokben Hizli Sayar

    2014-08-01

    Full Text Available Interpersonal Social Rhythm Therapy is a psychotherapy modality that helps the patient recognize the relationship between disruptions in social rhythms and the onset of previous episodes of psychiatric disorders. It uses psychoeducation and behavioral techniques to maintain social rhythm and sleep/wake regularity. It is closely related to and ldquo;social zeitgeber theory and rdquo; that emphasizes the importance that social rhythm regularity may play in synchronization of circadian rhythms in individuals with or at risk for bipolar spectrum disorders. Interpersonal and social rhythm therapy have been shown to stabilize social rhythms and enhance course and outcome in bipolar disorder. This review focuses on the theoretical principles and the basic steps of interpersonal and social rhythm therapy as a psychotherapy approach in bipolar disorder. PubMed, Scopus, Google Scholar databases were searched without temporal restriction. Search terms included interpersonal social rhythm therapy, bipolar, mood disorders. Abstracts were reviewed for relevance, and randomized controlled trials of interpersonal and social rhythm therapy in bipolar disorder selected. These researches also summarized on the final part of this review. [Psikiyatride Guncel Yaklasimlar - Current Approaches in Psychiatry 2014; 6(4.000: 438-446

  6. Cognitive functions in the euthymic patients with bipolar disorder

    International Nuclear Information System (INIS)

    Ozdel, O.; Karadag, F.; Atesci, Figen C.; Oguzhanoglu, N.K.; Cabuk, T.

    2007-01-01

    Recent studies have focused on the nature of dysfunction in bipolar patients. The purpose of the current study was to investigate cognitive performance of individuals with bipolar disorder compared to healthy control subjects during a well-established euthymic period. The sample consisted of 27 bipolar euthymic patients and 21 control subjects. Verbal and visual memory performance, attention, executive functions and psychological functions were evaluated for each participant. Bipolar patients showed significant attentional deficit and executive dysfunction and also poor performance on verbal and visual memory tasks compared to the controls. Illness duration and lifetime total episode number and previous episode with psychotic features was associated with worsened performance on attention, executive and memory tasks. Psychological functioning was not associated with cognitive deficit. The present study showed persistent cognitive impairment on inhibitory control and selective attention as well as poor performance on verbal and visual memory tests in a group of bipolar euthymic patients. The impaired neuropsychological performance was associated with psychotic features. Attentional dysfunction seemed to be a trait abnormality for the sample studied. (author)

  7. Stigma experiences in bipolar patients: the impact upon functioning.

    Science.gov (United States)

    Thomé, E S; Dargél, A A; Migliavacca, F M; Potter, W A; Jappur, D M C; Kapczinski, F; Ceresér, K M

    2012-10-01

    The aim of this study was to investigate the impact of self-rated stigma and functioning in patients with bipolar disorder in South Brazil. This is a cross-sectional study. Sixty participants with bipolar disorder were recruited from an outpatient Bipolar Disorder Program. Experiences with and impact of perceived stigma were evaluated using the Inventory of Stigmatizing Experiences. Functional impairment was assessed with the Functioning Assessment Short Test (FAST). Higher scores of self-perceived stigma were correlated with higher FAST scores, indicating more disability. After linear correlation analysis, current depressive symptoms, age at onset of treatment, age at diagnosis and functioning were correlated with self-perceived stigma. The study demonstrated a correlation between stigma and poor functioning in bipolar disorder. Perceived stigma is really important to individuals with bipolar disorder, both to how they experience their illness and to its results on functioning. Potential consequences of such results for mental health care professionals are discussed. Differential clinical features, sociocultural factors and the sample size limit the generalization of the present findings. © 2011 Blackwell Publishing.

  8. PEM fuel cell bipolar plate material requirements for transportation applications

    Energy Technology Data Exchange (ETDEWEB)

    Borup, R.L.; Stroh, K.R.; Vanderborgh, N.E. [Los Alamos National Lab., NM (United States)] [and others

    1996-04-01

    Cost effective bipolar plates are currently under development to help make proton exchange membrane (PEM) fuel cells commercially viable. Bipolar plates separate individual cells of the fuel cell stack, and thus must supply strength, be electrically conductive, provide for thermal control of the fuel stack, be a non-porous materials separating hydrogen and oxygen feed streams, be corrosion resistant, provide gas distribution for the feed streams and meet fuel stack cost targets. Candidate materials include conductive polymers and metal plates with corrosion resistant coatings. Possible metals include aluminium, titanium, iron/stainless steel and nickel.

  9. Connectivity of Pacemaker Neurons in the Neonatal Rat Superficial Dorsal Horn

    Science.gov (United States)

    Ford, Neil C.; Arbabi, Shahriar; Baccei, Mark L.

    2014-01-01

    Pacemaker neurons with an intrinsic ability to generate rhythmic burst-firing have been characterized in lamina I of the neonatal spinal cord, where they are innervated by high-threshold sensory afferents. However, little is known about the output of these pacemakers, as the neuronal populations which are targeted by pacemaker axons have yet to be identified. The present study combines patch clamp recordings in the intact neonatal rat spinal cord with tract-tracing to demonstrate that lamina I pacemaker neurons contact multiple spinal motor pathways during early life. Retrograde labeling of premotor interneurons with the trans-synaptic virus PRV-152 revealed the presence of burst-firing in PRV-infected lamina I neurons, thereby confirming that pacemakers are synaptically coupled to motor networks in the spinal ventral horn. Notably, two classes of pacemakers could be distinguished in lamina I based on cell size and the pattern of their axonal projections. While small pacemaker neurons possessed ramified axons which contacted ipsilateral motor circuits, large pacemaker neurons had unbranched axons which crossed the midline and ascended rostrally in the contralateral white matter. Recordings from identified spino-parabrachial and spino-PAG neurons indicated the presence of pacemaker activity within neonatal lamina I projection neurons. Overall, these results show that lamina I pacemakers are positioned to regulate both the level of activity in developing motor circuits as well as the ascending flow of nociceptive information to the brain, thus highlighting a potential role for pacemaker activity in the maturation of pain and sensorimotor networks in the CNS. PMID:25380417

  10. Why We Have to Use Cardiac Resynchronization Therapy-Pacemaker More.

    Science.gov (United States)

    Daubert, Jean-Claude; Martins, Raphaël; Leclercq, Christophe

    2015-12-01

    Both cardiac resynchronization therapy with a pacemaker (CRT-P) and with a biventricular implantable cardioverter-defibrillator (CRT-D) are electrical treatment modalities validated for the management of chronic heart failure. There is no strong scientific evidence that a CRT-D must be offered to all candidates. Common sense should limit the prescription of these costly and complicated devices. The choice of CRT-P is currently acceptable. A direction to explore could be to downgrade from CRT-D to CRT-P at the time of battery depletion in patients with large reverse remodeling and no ventricular tachycardia and ventricular fibrillation detected. Copyright © 2015 Elsevier Inc. All rights reserved.

  11. Bipolar Transistors Can Detect Charge in Electrostatic Experiments

    Science.gov (United States)

    Dvorak, L.

    2012-01-01

    A simple charge indicator with bipolar transistors is described that can be used in various electrostatic experiments. Its behaviour enables us to elucidate links between 'static electricity' and electric currents. In addition it allows us to relate the sign of static charges to the sign of the terminals of an ordinary battery. (Contains 7 figures…

  12. Modeling of the bipolar transistor under different pulse ionizing radiations

    Science.gov (United States)

    Antonova, A. M.; Skorobogatov, P. K.

    2017-01-01

    This paper describes a 2D model of the bipolar transistor 2T312 under gamma, X-ray and laser pulse ionizing radiations. Both the Finite Element Discretization and Semiconductor module of Comsol 5.1 are used. There is an analysis of energy deposition in this device under different radiations and the results of transient ionizing current response for some different conditions.

  13. Asymmetric bipolar membrane: A tool to improve product purity

    NARCIS (Netherlands)

    Balster, J.H.; Sumbharaju, R.; Srikantharajah, S.; Punt, Ineke G.M.; Stamatialis, Dimitrios; Jordan, V.; Wessling, Matthias

    2007-01-01

    Bipolar membranes (BPMs) are catalytic membranes for electro-membrane processes splitting water into protons and hydroxyl ions. To improve selectivity and current efficiency of BPMs, we prepare new asymmetric BPMs with reduced salt leakages. The flux of salt ions across a BPM is determined by the

  14. Assessing and addressing cognitive impairment in bipolar disorder

    DEFF Research Database (Denmark)

    Miskowiak, K W; Burdick, K E; Martinez-Aran, A

    2018-01-01

    OBJECTIVES: Cognition is a new treatment target to aid functional recovery and enhance quality of life for patients with bipolar disorder. The International Society for Bipolar Disorders (ISBD) Targeting Cognition Task Force aimed to develop consensus-based clinical recommendations on whether, when...... through these exchanges with no need for formal consensus methods. RESULTS: The identified questions were: (I) Should cognitive screening assessments be routinely conducted in clinical settings? (II) What are the most feasible screening tools? (III) What are the implications if cognitive impairment...... in Bipolar Disorder Rating Assessment, and (III) evaluate the impact of medication and comorbidity, refer patients for comprehensive neuropsychological evaluation when clinically indicated, and encourage patients to build cognitive reserve. Regarding question (IV), there is limited evidence for current...

  15. Peripheral blood brain-derived neurotrophic factor in bipolar disorder

    DEFF Research Database (Denmark)

    Munkholm, K; Vinberg, M; Kessing, L V

    2016-01-01

    subjects and between affective states in bipolar disorder patients, including assessment of the effect of treatment of acute episodes on BDNF levels. A systematic review of English language studies without considering publication status was conducted in PubMed (January 1950-November 2014), Embase (1974......Peripheral blood brain-derived neurotrophic factor (BDNF) has been proposed as a potential biomarker related to disease activity and neuroprogression in bipolar disorder, speculated to mirror alterations in brain expression of BDNF. The research area is rapidly evolving; however, recent...... investigations have yielded conflicting results with substantial variation in outcomes, highlighting the need to critically assess the state of current evidence. The aims of the study were to investigate differences in peripheral blood BDNF concentrations between bipolar disorder patients and healthy control...

  16. The effects of gamma irradiation on neutron displacement sensitivity of lateral PNP bipolar transistors

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Chenhui, E-mail: wangchenhui@nint.ac.cn; Chen, Wei; Liu, Yan; Jin, Xiaoming; Yang, Shanchao; Qi, Chao

    2016-09-21

    The effects of gamma irradiation on neutron displacement sensitivity of four types of lateral PNP bipolar transistors (LPNPs) with different neutral base widths, emitter widths and the doping concentrations of the epitaxial base region are studied. The physical mechanisms of the effects are explored by defect analysis using deep level transient spectroscopy (DLTS) techniques and numerical simulations of recombination process in the base region of the lateral PNP bipolar transistors, and are verified by the experiments on gate-controlled lateral PNP bipolar transistors (GCLPNPs) manufactured in the identical commercial bipolar process with different gate bias voltage. The results indicate that gamma irradiation increases neutron displacement damage sensitivity of lateral PNP bipolar transistors and the mechanism of this phenomenon is that positive charge induced by gamma irradiation enhances the recombination process in the defects induced by neutrons in the base region, leading to larger recombination component of base current and greater gain degradation.

  17. Electric modelling and image analysis of channel flow in bipolar plates

    Energy Technology Data Exchange (ETDEWEB)

    Martin, D.; Gonzalez, L.; Garcia-Alegre, M.C.; Guinea, D. [Instituto de Automatica Industrial, Consejo Superior de Investigaciones Cientificas, 28500 Arganda, Madrid (Spain); Guinea, D.M.; Moreno, B. [Instituto de Ceramica y Vidrio, Consejo Superior de Investigaciones Cientificas, Kelsen 5, 28049 Madrid (Spain)

    2007-07-15

    Bipolar plates are an essential part of Polymer Electrolyte Membrane Fuel Cells (PEMFC) and are related to fluid conduction. The topology of a bipolar plate is critical to the homogeneous distribution of the feeding gases over the accessible zone of the electrode. An electric model that simulates flow in bipolar plates and permits the optimisation of gas feeding in PEMFCs is proposed. As a first approach, an analogy is made between the gas pressure P and an electric voltage U in a circuit and a gas flow F and an electric current I. The fluidic resistance in a bipolar plate channel is thus R=P/F and is equivalent to the electric resistance R=U/I in a branch of a circuit. Computer image processing techniques allow the validation of the present flow estimation approach based on electrical variables. Separate plates were developed to experimentally implement a complete parallel bipolar topology. (author)

  18. Validity and reliability of the Cognitive Complaints in Bipolar Disorder Rating Assessment (COBRA) in Japanese patients with bipolar disorder.

    Science.gov (United States)

    Toyoshima, Kuniyoshi; Fujii, Yutaka; Mitsui, Nobuyuki; Kako, Yuki; Asakura, Satoshi; Martinez-Aran, Anabel; Vieta, Eduard; Kusumi, Ichiro

    2017-08-01

    In Japan, there are currently no reliable rating scales for the evaluation of subjective cognitive impairment in patients with bipolar disorder. We studied the relationship between the Japanese version of the Cognitive Complaints in Bipolar Disorder Rating Assessment (COBRA) and objective cognitive assessments in patients with bipolar disorder. We further assessed the reliability and validity of the COBRA. Forty-one patients, aged 16-64, in a remission period of bipolar disorder were recruited from Hokkaido University Hospital in Sapporo, Japan. The COBRA (Japanese version) and Frankfurt Complaint Questionnaire (FCQ), the gold standard in subjective cognitive assessment, were administered. A battery of neuropsychological tests was employed to measure objective cognitive impairment. Correlations among the COBRA, FCQ, and neuropsychological tests were determined using Spearman's correlation coefficient. The Japanese version of the COBRA had high internal consistency, good retest reliability, and concurrent validity-as indicated by a strong correlation with the FCQ. A significant correlation was also observed between the COBRA and objective cognitive measurements of processing speed. These findings are the first to demonstrate that the Japanese version of the COBRA may be clinically useful as a subjective cognitive impairment rating scale in Japanese patients with bipolar disorder. Copyright © 2017 Elsevier Ireland Ltd. All rights reserved.

  19. A graphite-coated carbon fiber epoxy composite bipolar plate for polymer electrolyte membrane fuel cell

    Science.gov (United States)

    Yu, Ha Na; Lim, Jun Woo; Suh, Jung Do; Lee, Dai Gil

    A PEMFC (polymer electrolyte membrane fuel cell or proton exchange membrane fuel cell) stack is composed of GDLs (gas diffusion layers), MEAs (membrane electrode assemblies), and bipolar plates. One of the important functions of bipolar plates is to collect and conduct the current from cell to cell, which requires low electrical bulk and interfacial resistances. For a carbon fiber epoxy composite bipolar plate, the interfacial resistance is usually much larger than the bulk resistance due to the resin-rich layer on the composite surface. In this study, a thin graphite layer is coated on the carbon/epoxy composite bipolar plate to decrease the interfacial contact resistance between the bipolar plate and the GDL. The total electrical resistance in the through-thickness direction of the bipolar plate is measured with respect to the thickness of the graphite coating layer, and the ratio of the bulk resistance to the interfacial contact resistance is estimated using the measured data. From the experiment, it is found that the graphite coating on the carbon/epoxy composite bipolar plate has 10% and 4% of the total electrical and interfacial contact resistances of the conventional carbon/epoxy composite bipolar plate, respectively, when the graphite coating thickness is 50 μm.

  20. Bipolar Disorder in Children and Teens

    Science.gov (United States)

    ... I do? Share Bipolar Disorder in Children and Teens Download PDF Download ePub Order a free hardcopy ... Think about death or suicide Can children and teens with bipolar disorder have other problems? Young people ...

  1. Interference of apex locator, pulp tester and diathermy on pacemaker function.

    Science.gov (United States)

    Sriman, Narayanan; Prabhakar, V; Bhuvaneswaran, J S; Subha, N

    2015-01-01

    The purpose of this study was to evaluate the effects of three electronic apex locators (EAL), electric pulp tester (EPT) and diathermy on pacemaker function in vitro. Three EALs: Root ZX (J. Morita Co., Tustin, CA, U.S.A.), Propex (Dentsply), Mini Apex locator (SybronEndo, Anaheim, CA, USA), EPT (Parkell pulp vitality tester Farmingdale, NY, USA) and Diathermy (Neomed 250 B) were tested for any interference with one pacemaker (A medtronic kappa KVDD901-serial number: PLE734632S). Directly connecting the pacemaker lead with the EAL/EPT/diathermy operating on a flat bench top, the telemetry wand was held directly over the pacemaker to monitor the pacing pattern for a period of 30 s. Pacemaker activity was continuously recorded on the telemetric programmer and electro gram (EGM) readings examined for pacer inhibition, noise reversion or inappropriate pacemaker pulses. All the three apex locators showed no pacing interference or background noise during its function or at rest. The EGM readings of EPT showed varying levels of background noise in between pacing however, this did not affect the normal pacing pattern and the pacing interval remained constant. EGM readings of diathermy showed an increase in the pacing interval (irregular pacing pattern) followed by complete inhibition of the pacing system. The tested EALs do not interfere with cardiac pacemaker function. The tested EPT showed varying levels of background noise but does not interfere with cardiac pacemaker function. Use of Diathermy interfered with the normal pacing, leading to complete inhibition of the pacing system.

  2. Sinus venosus atrial septal defect: a rare cause of misplacement of pacemaker leads

    Directory of Open Access Journals (Sweden)

    Bodian M

    2013-07-01

    Full Text Available Malick Bodian,1 Fatou Aw,1 Mouhamadou Bamba Ndiaye,1 Adama Kane,1 Modou Jobe,1 Alioune Tabane,1 Alassane Mbaye,2 Simon Antoine Sarr,1 Maboury Diao,1 Moustapha Sarr,1 Serigne Abdou Bâ1 1Department of Cardiology, Aristide Le Dantec Teaching Hospital, 2Grand Yoff General Hospital, Dakar, Senegal Abstract: Routine implantation of pacemakers and implantable cardioverter defibrillators is not commonly associated with complications. However, in some cases we see misplacement of pacemaker leads which is most often related to the presence of underlying cardiac anomalies. We report the case of misplacement of a pacemaker lead into the left ventricle of a 56-year-old patient paced in VVI/R mode and with a tined type pacemaker lead because of a symptomatic complete atrioventricular block. Electrocardiogram showed a pacemaker-generated rhythm with a right bundle branch block pattern. Chest X-ray showed the pacemaker lead located relatively high in relation to the diaphragm. Echocardiography visualized the pacemaker lead in the left heart chambers (atrium and ventricle, hence confirming its aberrant course. Further, the defect causing its passage to the left heart chambers was a sinus venosus atrial septal defect. The patient reported no complication related to the misplacement of the lead. After a brief period of oral anticoagulation, the lead was inserted into the right ventricle by percutaneous technique. Keywords: pacemaker, lead misplacement, sinus venosus atrial septal defect

  3. Pacemaker and radiotherapy in breast cancer: is targeted intraoperative radiotherapy the answer in this setting?

    International Nuclear Information System (INIS)

    Keshtgar, Mohammed RS; Eaton, David J; Reynolds, Claire; Pigott, Katharine; Davidson, Tim; Gauter-Fleckenstein, Benjamin; Wenz, Frederik

    2012-01-01

    We present the case of an 83 year old woman with a cardiac pacemaker located close in distance to a subsequently diagnosed invasive ductal carcinoma of the left breast. Short range intraoperative radiotherapy was given following wide local excision and sentinel node biopsy. The challenges of using ionising radiation with pacemakers is also discussed

  4. Dizzy Spells in a Patient with Hypertrophic Obstructive Cardiomyopathy and a Pacemaker

    OpenAIRE

    Wilschut, J. M.; de Voogt, W. G.

    2010-01-01

    Pacemaker syndrome represents the clinical consequences of the haemodynamic adverse effects of atrioventricular asynchrony during pacing. Patients suffering from hypertrophic cardiomyopathy may be particularly sensitive to these effects because of the importance of atrial systolic contribution to left ventricular diastolic filling. In this case report, we describe the symptoms and cause of pacemaker syndrome in a patient with hypertrophic obstructive cardiomyopathy.

  5. Subacute Right Ventricle Perforation by Pacemaker Lead Presenting with Left Hemothorax and Shock

    Directory of Open Access Journals (Sweden)

    Julianne Nichols

    2015-01-01

    Full Text Available Cardiac perforation by pacemaker is a rare but potentially fatal complication. Acute perforations occurring within twenty-four hours of insertion of pacemaker can lead to hemopericardium, cardiac tamponade, and death. Hemothorax occurring as an acute complication of pacemaker insertion is reported but extremely rare. Previously, hemothorax and shock as a subacute complication following pacemaker insertion have not been reported. We report the case of an 85-year-old patient who presented with shock from hemothorax caused by pacemaker perforation, two weeks after insertion. Device interrogation showed normal function. Chest X-ray and echocardiogram missed lead dislocation and the diagnosis was made on computed tomogram (CT of the chest. Following surgical repair, a new ventricular pacemaker was placed transvenously in the right ventricular septum. This case illustrates that CT scan of the chest should be performed in all patients in whom cardiac perforation by pacemaker is suspected but not diagnosed on chest X-ray and echocardiogram. Normal functioning of pacemaker on device interrogation does not exclude perforation.

  6. Subacute right ventricle perforation by pacemaker lead presenting with left hemothorax and shock.

    Science.gov (United States)

    Nichols, Julianne; Berger, Natalie; Joseph, Praveen; Datta, Debapriya

    2015-01-01

    Cardiac perforation by pacemaker is a rare but potentially fatal complication. Acute perforations occurring within twenty-four hours of insertion of pacemaker can lead to hemopericardium, cardiac tamponade, and death. Hemothorax occurring as an acute complication of pacemaker insertion is reported but extremely rare. Previously, hemothorax and shock as a subacute complication following pacemaker insertion have not been reported. We report the case of an 85-year-old patient who presented with shock from hemothorax caused by pacemaker perforation, two weeks after insertion. Device interrogation showed normal function. Chest X-ray and echocardiogram missed lead dislocation and the diagnosis was made on computed tomogram (CT) of the chest. Following surgical repair, a new ventricular pacemaker was placed transvenously in the right ventricular septum. This case illustrates that CT scan of the chest should be performed in all patients in whom cardiac perforation by pacemaker is suspected but not diagnosed on chest X-ray and echocardiogram. Normal functioning of pacemaker on device interrogation does not exclude perforation.

  7. Zebrafish heart as a model to study the integrative autonomic control of pacemaker function

    Science.gov (United States)

    Stoyek, Matthew R.; Quinn, T. Alexander; Croll, Roger P.

    2016-01-01

    The cardiac pacemaker sets the heart's primary rate, with pacemaker discharge controlled by the autonomic nervous system through intracardiac ganglia. A fundamental issue in understanding the relationship between neural activity and cardiac chronotropy is the identification of neuronal populations that control pacemaker cells. To date, most studies of neurocardiac control have been done in mammalian species, where neurons are embedded in and distributed throughout the heart, so they are largely inaccessible for whole-organ, integrative studies. Here, we establish the isolated, innervated zebrafish heart as a novel alternative model for studies of autonomic control of heart rate. Stimulation of individual cardiac vagosympathetic nerve trunks evoked bradycardia (parasympathetic activation) and tachycardia (sympathetic activation). Simultaneous stimulation of both vagosympathetic nerve trunks evoked a summative effect. Effects of nerve stimulation were mimicked by direct application of cholinergic and adrenergic agents. Optical mapping of electrical activity confirmed the sinoatrial region as the site of origin of normal pacemaker activity and identified a secondary pacemaker in the atrioventricular region. Strong vagosympathetic nerve stimulation resulted in a shift in the origin of initial excitation from the sinoatrial pacemaker to the atrioventricular pacemaker. Putative pacemaker cells in the sinoatrial and atrioventricular regions expressed adrenergic β2 and cholinergic muscarinic type 2 receptors. Collectively, we have demonstrated that the zebrafish heart contains the accepted hallmarks of vertebrate cardiac control, establishing this preparation as a viable model for studies of integrative physiological control of cardiac function by intracardiac neurons. PMID:27342878

  8. Iatrogenic perforation of the posterior mitral valve leaflet: a rare complication of pacemaker lead placement

    NARCIS (Netherlands)

    Konings, Thelma C.; Koolbergen, Dave R.; Bouma, Berto J.; Groenink, Maarten; Mulder, Barbara J.

    2008-01-01

    An inadvertently placed pacing lead in the left ventricle (LV) is a rare and often underdiagnosed complication of pacemaker implantation. We present a case of a 73-year-old woman who was evaluated for dyspnea, 10 years after transvenous pacemaker implantation. Transthoracic and transesophageal

  9. Twiddler-syndrom er en årsag til pacemaker elektrode displacering

    DEFF Research Database (Denmark)

    Grønbech, Keea Treu; Hansen, Michael Gilså

    2013-01-01

    Twiddler's syndrome is a rare cause of pacemaker electrode displacement. The displacement is caused by the patient's manipulation with the pacemaker, so the electrode is retracted. We describe a case of a 79-year-old overweight woman with a known psychiatric anamnesis, who was admitted twice...

  10. A forced desynchrony study of circadian pacemaker characteristics in seasonal affective disorder

    NARCIS (Netherlands)

    Koorengevel, Kathelijne M.; Beersma, Domien G.M.; den Boer, Johan; Hoofdakker, Rutger H. van den

    2002-01-01

    The circadian pacemaker is an endogenous clock that regulates oscillations in most physiological and psychological processes with a near 24-h period. In many species, this pacemaker triggers seasonal changes in behavior. The seasonality of symptoms and the efficacy of light therapy suggest

  11. Exercising control over bipolar disorder.

    Science.gov (United States)

    Malhi, Gin S; Byrow, Yulisha

    2016-11-01

    Following extensive research exercise has emerged as an effective treatment for major depressive disorder, and it is now a recognised therapy alongside other interventions. In contrast, there is a paucity of research examining the therapeutic effects of exercise for those with bipolar disorder. Given that dysfunctional reward processing is central to bipolar disorder, research suggests that exercise can perhaps be framed as a reward-related event that may have the potential to precipitate a manic episode. The behavioural activation system (BAS) is a neurobehavioural system that is associated with responding to reward and provides an appropriate framework to theoretically examine and better understand the effects of exercise treatment on bipolar disorder. This article discusses recent research findings and provides an overview of the extant literature related to the neurobiological underpinnings of BAS and exercise as they relate to bipolar disorder. This is important clinically because depending on mood state in bipolar disorder, we postulate that exercise could be either beneficial or deleterious with positive or negative effects on the illness. Clearly, this complicates the evaluation of exercise as a potential treatment in terms of identifying its optimal characteristics in this population. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.

  12. Patients With Co-Occurring Bipolar Disorder and Posttraumatic Stress Disorder: A Rapid Review of the Literature.

    Science.gov (United States)

    Cerimele, Joseph M; Bauer, Amy M; Fortney, John C; Bauer, Mark S

    2017-05-01

    To summarize the current literature on epidemiology, clinical correlates, and treatment of individuals with co-occurring bipolar disorder and posttraumatic stress disorder (PTSD). We conducted a focused, time-sensitive review called "rapid review" in November 2015, using keyword searches (including keywords bipolar disorder, post-traumatic stress disorder, PTSD, and others) in PubMed for studies of adults with co-occurring bipolar disorder and PTSD. Results were sorted and systematically searched. An article was excluded if it did not describe adult patients with co-occurring PTSD and bipolar disorder or did not report original data on epidemiology, clinical correlates, or treatment. Information on study characteristics including population studied and key findings were extracted onto a data collection tool. Thirty-two articles were included. Over two-thirds of articles reported epidemiology of co-occurring bipolar disorder and PTSD. Prevalence of PTSD among individuals with bipolar disorder ranged from 4% to 40%, with women and those with bipolar I versus bipolar II disorder experiencing higher prevalence of PTSD. Prevalence of bipolar disorder among individuals with PTSD ranged from 6% to 55%. Baseline PTSD or bipolar disorder was associated with incidence of the other illness. Individuals with co-occurring bipolar disorder and PTSD experienced high symptom burden and low quality of life. No studies evaluated prospective treatment of patients with co-occurring bipolar disorder and PTSD. Bipolar disorder and PTSD commonly co-occur and result in greater symptom burden than either condition alone. Few published treatment strategies exist for patients with both conditions. © Copyright 2017 Physicians Postgraduate Press, Inc.

  13. Differences in the ICD-10 diagnostic subtype of depression in bipolar disorder compared to recurrent depressive disorder

    DEFF Research Database (Denmark)

    Jensen, H.M.; Christensen, E.M.; Kessing, Lars Vedel

    2008-01-01

    Background: The aim of the study was to investigate whether patients with bipolar depression and patients with recurrent depressive disorder present with different subtypes of depressive episode as according to ICD-10. Sampling and Methods: All patients who got a diagnosis of bipolar affective......: Totally, 389 patients got a diagnosis of bipolar disorder, current episode of depression, and 5.391 patients got a diagnosis of recurrent depressive disorder, current episode of depression, at first contact. Compared with patients with a diagnosis of recurrent depressive disorder, patients with bipolar...... for patients with bipolar disorder, current episode of depression, compared with patients with a current depression as part of a recurrent depressive disorder (HR = 1.50, 95% CI = 1.20-1.86). Conclusions: The results consistently indicate that a depressive episode is severer and/or more often associated...

  14. Imunologia do transtorno bipolar Immunology of bipolar disorder

    Directory of Open Access Journals (Sweden)

    Izabela Guimarães Barbosa

    2009-01-01

    Full Text Available OBJETIVO: Pesquisas recentes têm implicado fatores imunes na patogênese de diversos transtornos neuropsiquiátricos. O objetivo do presente trabalho é revisar os trabalhos que investigaram a associação entre transtorno bipolar e alterações em parâmetros imunes. MÉTODOS: Artigos que incluíam as palavras-chave: "bipolar disorder", "mania", "immunology", "cytokines", "chemokines", "interleukins", "interferon" e "tumor necrosis factor" foram selecionados em uma revisão sistemática da literatura. As bases de dados avaliadas foram MedLine e Scopus, entre os anos de 1980 e 2008. RESULTADOS: Foram identificados 28 trabalhos que estudaram alterações imunes em pacientes com transtorno bipolar. Seis artigos investigaram genes relacionados à resposta imune; cinco, autoanticorpos; quatro, populações leucocitárias; 13, citocinas e/ou moléculas relacionadas à resposta imune e seis, leucócitos de pacientes in vitro. CONCLUSÕES: Embora haja evidências na literatura correlacionando o transtorno bipolar a alterações imunes, os dados não são conclusivos. O transtorno bipolar parece estar associado a níveis mais elevados de autoanticorpos circulantes, assim como à tendência à ativação imune com produção de citocinas pró-inflamatórias e redução de parâmetros anti-inflamatórios.OBJECTIVE: Emerging research has implicated immune factors in the pathogenesis of a variety of neuropsychiatric disorders. The objective of the present paper is to review the studies that investigated the association between bipolar disorder and immune parameters. METHODS: Papers that included the keywords "bipolar to disorder", "mania", "immunology", "cytokines", "chemokines", "interleukins", "interferon" and "tumor necrosis factor" were selected in a systematic review of the literature. The evaluated databases were MedLine and Scopus in the period between 1980 and 2008. RESULTS: Twenty eight works were found. Six studies investigated immune response

  15. Stroke rehabilitation therapy in a patient with a cardiac pacemaker for chronic atrial fibrillation.

    Science.gov (United States)

    Muramatsu, Hikaru; Koike, Kimiko

    2003-12-01

    A 65-year-old man was implanted with an artificial pacemaker for chronic bradycardic atrial fibrillation associated with hypertensive heart disease. Five years after the pacemaker implantation, he suffered from a cerebral embolism. Approximately 4.5 months after the ictus, he was transferred to the rehabilitation ward. He had flaccid left hemiplegia and severe disuse syndrome. He could not sit and could tilt his head up for only two minutes because of severe orthostatic hypotension. By modulating the rate-responsive mode of the pacemaker every 2-4 weeks, we were able to rehabilitate the patient. Thus, the patient could sit in a wheelchair for more than three hours. This case emphasizes the importance of examining the mode and function of a previously implanted artificial pacemaker. In accord with varying rehabilitation programs and gradual improvement in a patient's physical activities, periodic modulation of a programmable pacemaker can lead to a better functional outcome during rehabilitation therapy.

  16. A leadless pacemaker in the real-world setting

    DEFF Research Database (Denmark)

    Roberts, Paul R.; Clementy, Nicolas; Al Samadi, Faisal

    2017-01-01

    -approval setting. The safety end point was system- or procedure-related major complications at 30 days post implant. We compared the major complication rate with that of the 726 patients from the investigational study. Electrical performance was also characterized. Results The device was successfully implanted...... were low and stable. Conclusion Performance of the Micra transcatheter pacemaker in a real-world setting demonstrates a high rate (99.6%) of implant success and low rate (1.51%) of major complications through 30 days post implant. In particular, the rates of pericardial effusion, device dislodgement...

  17. Polyphosphonium-based ion bipolar junction transistors.

    Science.gov (United States)

    Gabrielsson, Erik O; Tybrandt, Klas; Berggren, Magnus

    2014-11-01

    Advancements in the field of electronics during the past few decades have inspired the use of transistors in a diversity of research fields, including biology and medicine. However, signals in living organisms are not only carried by electrons but also through fluxes of ions and biomolecules. Thus, in order to implement the transistor functionality to control biological signals, devices that can modulate currents of ions and biomolecules, i.e., ionic transistors and diodes, are needed. One successful approach for modulation of ionic currents is to use oppositely charged ion-selective membranes to form so called ion bipolar junction transistors (IBJTs). Unfortunately, overall IBJT device performance has been hindered due to the typical low mobility of ions, large geometries of the ion bipolar junction materials, and the possibility of electric field enhanced (EFE) water dissociation in the junction. Here, we introduce a novel polyphosphonium-based anion-selective material into npn-type IBJTs. The new material does not show EFE water dissociation and therefore allows for a reduction of junction length down to 2 μm, which significantly improves the switching performance of the ion transistor to 2 s. The presented improvement in speed as well the simplified design will be useful for future development of advanced iontronic circuits employing IBJTs, for example, addressable drug-delivery devices.

  18. Mathematical models of bipolar disorder

    Science.gov (United States)

    Daugherty, Darryl; Roque-Urrea, Tairi; Urrea-Roque, John; Troyer, Jessica; Wirkus, Stephen; Porter, Mason A.

    2009-07-01

    We use limit cycle oscillators to model bipolar II disorder, which is characterized by alternating hypomanic and depressive episodes and afflicts about 1% of the United States adult population. We consider two non-linear oscillator models of a single bipolar patient. In both frameworks, we begin with an untreated individual and examine the mathematical effects and resulting biological consequences of treatment. We also briefly consider the dynamics of interacting bipolar II individuals using weakly-coupled, weakly-damped harmonic oscillators. We discuss how the proposed models can be used as a framework for refined models that incorporate additional biological data. We conclude with a discussion of possible generalizations of our work, as there are several biologically-motivated extensions that can be readily incorporated into the series of models presented here.

  19. Complications of pacemaker therapy in adults with congenital heart disease: a multicenter study.

    Science.gov (United States)

    Opić, Petra; van Kranenburg, Matthijs; Yap, Sing-Chien; van Dijk, Arie P; Budts, Werner; Vliegen, Hubert W; van Erven, Lieselot; Can, Anil; Sahin, Gulhan; Theuns, Dominic A M J; Witsenburg, Maarten; Roos-Hesselink, Jolien W

    2013-10-09

    This study aims to investigate indications and complications of permanent cardiac pacing in adults with congenital heart disease (CHD). Two-hundred and seventy-four CHD patients were identified who underwent permanent pacemaker implantation between 1972 and 2009. The indication for pacing was acquired sinus node or AV node conduction disease (63%), sinus node or AV node conduction disease after cardiac surgery (28%), and drug/arrhythmia-related indications (9%). Patients with complex CHD received a pacemaker at younger age (23 versus 31 years, ppacemaker implantation (general population: 5.2%). The most common acute complications were lead dysfunction (4.0%), bleeding (2.6%), pocket infection (1.5%) and pneumothorax (1.5%). During a median follow-up of 12 years, pacemaker-related complications requiring intervention occurred in 95 patients (34.6%). The most common late pacemaker-related complications included lead failure (24.8%), pacemaker dysfunction/early battery depletion (5.1%), pacemaker migration (4.7%) and erosion (4.7%). Pacemaker implantation at younger age (pacemaker-related complication (adjusted hazard ratio 1.68, 95% confidence interval 1.07 to 2.63, p=0.023). The risk of periprocedural complications seems higher in the CHD population compared to the general population and more than one-third of CHD patients encountered a pacemaker-related complication during long-term follow-up. This risk increases for those who receive a pacemaker at younger age. Crown Copyright © 2013. Published by Elsevier Ireland Ltd. All rights reserved.

  20. Magnetic resonance imaging in patients with cardiac pacemakers: era of "MR Conditional" designs

    Directory of Open Access Journals (Sweden)

    Shellock Frank G

    2011-10-01

    Full Text Available Abstract Advances in cardiac device technology have led to the first generation of magnetic resonance imaging (MRI conditional devices, providing more diagnostic imaging options for patients with these devices, but also new controversies. Prior studies of pacemakers in patients undergoing MRI procedures have provided groundwork for design improvements. Factors related to magnetic field interactions and transfer of electromagnetic energy led to specific design changes. Ferromagnetic content was minimized. Reed switches were modified. Leads were redesigned to reduce induced currents/heating. Circuitry filters and shielding were implemented to impede or limit the transfer of certain unwanted electromagnetic effects. Prospective multicenter clinical trials to assess the safety and efficacy of the first generation of MR conditional cardiac pacemakers demonstrated no significant alterations in pacing parameters compared to controls. There were no reported complications through the one month visit including no arrhythmias, electrical reset, inhibition of generator output, or adverse sensations. The safe implementation of these new technologies requires an understanding of the well-defined patient and MR system conditions. Although scanning a patient with an MR conditional device following the strictly defined patient and MR system conditions appears straightforward, issues related to patients with pre-existing devices remain complex. Until MR conditional devices are the routine platform for all of these devices, there will still be challenging decisions regarding imaging patients with pre-existing devices where MRI is required to diagnose and manage a potentially life threatening or serious scenario. A range of other devices including ICDs, biventricular devices, and implantable physiologic monitors as well as guidance of medical procedures using MRI technology will require further biomedical device design changes and testing. The development and

  1. A pacemaker magnet check alone is sufficient for the majority of patients postpacemaker implant.

    Science.gov (United States)

    Jones, Michael A; Wong, Kelvin C K; Qureshi, Norman; Rajappan, Kim; Bashir, Yaver; Betts, Timothy R

    2014-12-01

    Patients postpacemaker implant can undergo a full assessment by pacing system programmer (PSP) or a magnet check. The former takes longer, but provides more detailed information; a magnet-mode assessment is faster, but provides only capture data in an asynchronous pacing mode. A magnet-mode assessment alone may be sufficient in most cases, and current clinical practice varies considerably. A retrospective single-center assessment of all pacemaker implants receiving PSP and magnet checks between September 2009 and April 2010. Patient records were reviewed. The results of PSP and magnet checks and any subsequent device-related management were noted. A total of 168 patients underwent pacemaker implantation, magnet-mode assessment, and then PSP interrogation during this period. Magnet-mode assessment revealed a problem in only one patient-failure of atrial capture, leading to subsequent atrial lead repositioning. None of the remaining 167 patients have a serious problem at PSP interrogation; six had minor issues at PSP check, none of which required repeat surgical intervention. The magnet-mode test only provides information on lead capture in an asynchronous pacing mode, which is the most essential data postoperatively. Our study has suggested that a magnet-mode assessment without PSP interrogation may be sufficient in the immediate postimplant assessment of these patients. Routine postimplant PSP interrogation is time consuming, labor intensive, and adds only minimal additional benefit to the safe management of these patients above and beyond a magnet check, coupled with informed assessment of the associated electrocardiogram/rhythm strip, clinical examination, and chest x-ray. ©2014 Wiley Periodicals, Inc.

  2. Transcultural aspects of bipolar disorder

    OpenAIRE

    Sanches, Marsal; Jorge, Miguel Roberto

    2004-01-01

    Considerando-se que existem diferenças importantes na maneira como as emoções são vivenciadas e expressas em diferentes culturas, a apresentação e o manejo do transtorno afetivo bipolar sofrem influência de fatores culturais. O presente artigo realiza uma breve revisão da evidência referente aos aspectos transculturais do transtorno bipolar.Cultural variations in the expression of emotions have been described. Consequently, there are cross-cultural influences on the diagnosis and management o...

  3. An update on adjunctive treatment options for bipolar disorder.

    Science.gov (United States)

    Dean, Olivia M; Gliddon, Emma; Van Rheenen, Tamsyn E; Giorlando, Francesco; Davidson, Sandra K; Kaur, Manreena; Ngo, Trung T; Williams, Lana J

    2018-03-01

    Bipolar disorder is a complex illness often requiring combinations of therapies to successfully treat symptoms. In recent years, there have been significant advancements in a number of therapies for bipolar disorder. It is therefore timely to provide an overview of current adjunctive therapeutic options to help treating clinicians to inform their patients and work towards optimal outcomes. Publications were identified from PubMed searches on bipolar disorder and pharmacotherapy, nutraceuticals, hormone therapy, psychoeducation, interpersonal and social rhythm therapy, cognitive remediation, mindfulness, e-Health and brain stimulation techniques. Relevant articles in these areas were selected for further review. This paper provides a narrative review of adjunctive treatment options and is not a systematic review of the literature. A number of pharmacotherapeutic, psychological and neuromodulation treatment options are available. These have varying efficacy but all have shown benefit to people with bipolar disorder. Due to the complex nature of treating the disorder, combination treatments are often required. Adjunctive treatments to traditional pharmacological and psychological therapies are proving useful in closing the gap between initial symptom remission and full functional recovery. Given that response to monotherapy is often inadequate, combination regimens for bipolar disorder are typical. Correspondingly, psychiatric research is working towards a better understanding of the disorder's underlying biology. Therefore, treatment options are changing and adjunctive therapies are being increasingly recognized as providing significant tools to improve patient outcomes. Towards this end, this paper provides an overview of novel treatments that may improve clinical outcomes for people with bipolar disorder. © 2018 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  4. Neuroleptic-induced deficit syndrome in bipolar disorder with psychosis

    Directory of Open Access Journals (Sweden)

    Ueda S

    2016-02-01

    Full Text Available Satoshi Ueda,1 Takeshi Sakayori,1 Ataru Omori,2 Hajime Fukuta,3 Takashi Kobayashi,3 Kousuke Ishizaka,1 Tomoyuki Saijo,4 Yoshiro Okubo1 1Department of Neuropsychiatry, Nippon Medical School, Tokyo, Japan; 2Tamachuo Hospital, Tokyo, Japan; 3Kurumegaoka Hospital, Tokyo, Japan; 4Saijo Clinic, Tokyo, Japan Abstract: Neuroleptics can induce not only physical adverse effects but also mental effects that produce deficit status in thought, affect, cognition, and behavior. This condition is known as neuroleptic-induced deficit syndrome (NIDS, which includes apathy, lack of initiative, anhedonia, indifference, blunted affect, and reduced insight into disease. Although this old concept now appears almost forgotten, neuroleptics, whether typical or atypical, can make depression or bipolar disorder resemble other more refractory conditions, readily leading to mistaken diagnosis and inappropriate treatment. The authors describe three cases of NIDS superimposed on depressive phase in bipolar disorder with psychosis, where the attending psychiatrist’s failure to recognize NIDS prevented patients from receiving effective treatment and achieving remission. All cases achieved remission after reduction of neuroleptics and intensive therapy, including electroconvulsive therapy, for bipolar depression. The concept of NIDS was originally introduced for schizophrenia, and it has rarely been highlighted in other diseases. In recent years, however, atypical antipsychotics are being more often administered to patients with bipolar disorder. Psychiatrists, therefore, should also remember and exercise caution regarding NIDS in the pharmacotherapy of bipolar disorder with and without psychosis. The authors believe that the concept of NIDS needs to be reappraised in current psychiatry. Keywords: neuroleptic-induced deficit syndrome (NIDS, bipolar disorder, psychosis, atypical antipsychotics, electroconvulsive therapy

  5. Positive Traits in the Bipolar Spectrum: The Space between Madness and Genius

    Science.gov (United States)

    Greenwood, Tiffany A.

    2017-01-01

    Bipolar disorder is a severe, lifelong mood disorder for which little is currently understood of the genetic mechanisms underlying risk. By examining related dimensional phenotypes, we may further our understanding of the disorder. Creativity has a historical connection with the bipolar spectrum and is particularly enhanced among unaffected first-degree relatives and those with bipolar spectrum traits. This suggests that some aspects of the bipolar spectrum may confer advantages, while more severe expressions of symptoms negatively influence creative accomplishment. Creativity is a complex, multidimensional construct with both cognitive and affective components, many of which appear to reflect a shared genetic vulnerability with bipolar disorder. It is suggested that a subset of bipolar risk variants confer advantages as positive traits according to an inverted-U-shaped curve with clinically unaffected allele carriers benefitting from the positive traits and serving to maintain the risk alleles in the population. The association of risk genes with creativity in healthy individuals (e.g., NRG1), as well as an overall sharing of common genetic variation between bipolar patients and creative individuals, provides support for this model. Current findings are summarized from a multidisciplinary perspective to demonstrate the feasibility of research in this area to reveal the mechanisms underlying illness. PMID:28277566

  6. Exfoliated MoS2 nanosheets loaded on bipolar exchange membranes interfaces as advanced catalysts for water dissociation

    DEFF Research Database (Denmark)

    Li, Jian; Morthensen, Sofie Thage; Zhu, Junyong

    2018-01-01

    Over the last few decades, ion exchange membranes have evolved from a laboratory tool to industrial products with significant technical and commercial impacts. Electrodialysis with bipolar membranes (EDBM) is a technology that can produce acids and bases from the corresponding salt solutions....... Bipolar membranes are key factors for splitting water at the interface of a cation and anion exchange layer in an electric field. The ideal bipolar membrane should have a low energy consumption, a high current efficiency and long-term stability. In order to investigate the catalytic effect of a monolayer...... this prediction. Furthermore, a bipolar membrane prepared at 90°C had a low swelling ratio of about 7.5% while maintaining a high water uptake of 71.6%. From the calculation of current efficiency and energy consumption, the bipolar membrane with a monolayer of MoS2 has a higher current efficiency (45...

  7. Micropatterning of a Bipolar Plate Using Direct Laser Melting Process

    Science.gov (United States)

    Jang, Jeong-hwan; Joo, Byeong-don; Mun, Sung-min; Moona, Young-hoon

    2010-06-01

    Direct laser melting (DLM) technology has been used to fabricate the micro-pattern of the bipolar plate in a direct methanol fuel cell (DMFC). A suitable approach to enhance the performance of the bipolar plate has been performed to optimize the DLM process. To fabricate the micro pattern, a DLM process with 316L stainless steel powder has been used. For the melted height of 1 mm, the DLM process conditions were optimized such as; laser power of 200 W, scan rate of 36.62 mm/s and the 8-layer structures. To characterize the effect of material type, the bipolar plates of various types were analyzed. In case of the 316L stainless steel DLM patterning, a current density of 297 mA/cm2 was achieved but the case of the 316L stainless steel plate, 248 mA/cm2 current density that is lower than that of other materials was achieved. The overall cell performance of 316L stainless steel DLM patterning bipolar plate was better than that of the 316L stainless steel plate. This has significant advantages for the micropatterning using DLM process. The use of 316L stainless steel powder material as micro pattern material will reduce the machining cost as well as volume of the fuel cell stack.

  8. Epidemiologia do transtorno bipolar Epidemiology of bipolar disorders

    Directory of Open Access Journals (Sweden)

    Maurício Silva de Lima

    2005-01-01

    Full Text Available A formulação de políticas em saúde mental depende essencialmente de informações a respeito da freqüência e distribuição dos transtornos mentais. Nas últimas duas décadas, pesquisas de base populacional em epidemiologia psiquiátrica têm sido conduzidas, gerando informações detalhadas sobre freqüência, fatores de risco, incapacidade social e utilização de serviços de saúde. Neste artigo, dados sobre a epidemiologia do transtorno bipolar (TB são discutidos, a partir de resultados de recentes pesquisas populacionais: o estudo da Área de Captação Epidemiológica do Instituto Nacional de Saúde Mental dos Estados Unidos (ECA-NIMH, a Pesquisa Nacional de Comorbidade (NCS, a Pesquisa de Morbidade Psiquiátrica na Grã-Bretanha (OPCS, o Estudo Brasileiro Multicêntrico de Morbidade Psiquiátrica e os estudos longitudinais conduzidos por Angst, em Zurique. As estimativas de prevalências de transtorno bipolar são relativamente baixas, independentemente do lugar onde a pesquisa foi conduzida, do tipo de instrumento diagnóstico usado e dos períodos de tempo para os quais a prevalência se aplica. A partir da introdução do conceito de espectro bipolar, ampliando as fronteiras diagnósticas do TB, as estimativas de prevalências encontradas são substancialmente mais altas. Tais estimativas, entretanto, ainda carecem de validação em estudos populacionais. O transtorno afetivo bipolar é igualmente prevalente entre homens e mulheres, sendo mais freqüente entre solteiros ou separados. Indivíduos acometidos têm maiores taxas de desemprego e estão mais sujeitos a utilizarem serviços médicos e serem hospitalizados. O custo e a eficácia dos tratamentos do TB devem ser balanceados com o alto custo individual e social associados à enfermidade.Information about the epidemiology of bipolar disorders is essential for providing a framework for the formulation of effective mental health policy. In the last two decades, population

  9. Mental Health Comorbidity in MS: Depression, Anxiety, and Bipolar Disorder.

    Science.gov (United States)

    Turner, Aaron P; Alschuler, Kevin N; Hughes, Abbey J; Beier, Meghan; Haselkorn, Jodie K; Sloan, Alicia P; Ehde, Dawn M

    2016-12-01

    Among individuals with multiple sclerosis (MS), mental health comorbidities play a significant role in contributing to secondary disability and detracting from quality of life. This review examines current evidence surrounding three mental health issues of particular relevance to MS: depression, anxiety, and bipolar disorder. We review what is known of the prevalence, correlates, screening mechanisms, and current treatment of each issue and provide recommendations for future areas of research.

  10. The Micra Leadless Transcatheter Pacemaker. Implantation and Mid-term Follow-up Results in a Single Center.

    Science.gov (United States)

    Martínez-Sande, José Luis; García-Seara, Javier; Rodríguez-Mañero, Moisés; Fernández-López, Xesús Alberte; González-Melchor, Laila; Redondo-Diéguez, Alfredo; González-Ferreiro, Rocío; González-Juanatey, José Ramón

    2017-04-01

    Currently, studies on the leadless pacemaker (Micra) have mostly been limited to clinical trials with less than 6 months' follow-up and they often fail to reflect real population outcomes. We sought to evaluate electrical parameters at implantation and chronologically during follow-up, as well as the safety of this new technique. This prospective, observational study included 30 consecutive patients, all ≥ 65 years, with an indication for single-chamber pacemaker implantation. Successful implantation was accomplished in all patients referred for leadless implantation. The mean age was 79.4±6.4 years (range, 66-89 years); 20 (66.6%) were men and 28 had permanent atrial fibrillation (93.3%); 1 had atrial tachycardia and 1 had sinus rhythm. Concomitant atrioventricular node ablation was performed immediately after implantation in 5 patients (16.6%), and implantation was performed after transcatheter aortic valve implantation in 2. The procedure was performed under an uninterrupted anticoagulation regimen (maximum INR 2.4) in 23 patients (76.6%). With the exception of 1 moderate pericardial effusion without tamponade, there were no severe complications. The mean follow-up was 5.3±3.3 months and 4 patients had more than 1 year of follow-up. Sensing and pacing parameters were stable both at implantation and during the short- to mid-term follow-up. Implantation of leadless pacemakers is feasible, safe and provides advantages over the conventional system. Further studies with longer follow-up periods will be needed before these devices become widely used in routine clinical practice. Copyright © 2016 Sociedad Española de Cardiología. Published by Elsevier España, S.L.U. All rights reserved.

  11. Mixed features in bipolar disorder.

    Science.gov (United States)

    Solé, Eva; Garriga, Marina; Valentí, Marc; Vieta, Eduard

    2017-04-01

    Mixed affective states, defined as the coexistence of depressive and manic symptoms, are complex presentations of manic-depressive illness that represent a challenge for clinicians at the levels of diagnosis, classification, and pharmacological treatment. The evidence shows that patients with bipolar disorder who have manic/hypomanic or depressive episodes with mixed features tend to have a more severe form of bipolar disorder along with a worse course of illness and higher rates of comorbid conditions than those with non-mixed presentations. In the updated Diagnostic and Statistical Manual of Mental Disorders (5th ed.; DSM-5), the definition of "mixed episode" has been removed, and subthreshold nonoverlapping symptoms of the opposite pole are captured using a "with mixed features" specifier applied to manic, hypomanic, and major depressive episodes. However, the list of symptoms proposed in the DSM-5 specifier has been widely criticized, because it includes typical manic symptoms (such as elevated mood and grandiosity) that are rare among patients with mixed depression, while excluding symptoms (such as irritability, psychomotor agitation, and distractibility) that are frequently reported in these patients. With the new classification, mixed depressive episodes are three times more common in bipolar II compared with unipolar depression, which partly contributes to the increased risk of suicide observed in bipolar depression compared to unipolar depression. Therefore, a specific diagnostic category would imply an increased diagnostic sensitivity, would help to foster early identification of symptoms and ensure specific treatment, as well as play a role in suicide prevention in this population.

  12. Transvenous permanent pacemaker implantation in dextrocardia: technique, challenges, outcome, and a brief review of literature.

    Science.gov (United States)

    Shenthar, Jayaprakash; Rai, Maneesh K; Walia, Rohit; Ghanta, Somasekhar; Sreekumar, Praveen; Reddy, Satish S

    2014-09-01

    Dextrocardia is a rare congenital anomaly. Pacemaker implantation in dextrocardia can be challenging because of the distorted anatomy and associated anomalies. The literature regarding implantation of pacemaker in dextrocardia is scarce. The study involved retrospective analysis of records of patients with dextrocardia who had undergone pacemaker implantation between January 2006 and July 2013 from a single centre. Six patients with dextrocardia (five males and one female) underwent permanent pacemaker implantation (PPI) between January 2006 and July 2013. Of them, three had situs solitus dextrocardia and three situs inversus dextrocardia. All three patients with situs solitus dextrocardia had associated corrected transposition of great arteries. The indication for pacemaker implantation was symptomatic complete atrioventricular (AV) block in four, high-grade AV block in one, and sinus node dysfunction in one patient. A favourable outcome was noted during a mean follow-up of 3.9 years (4 months to 7 years) with one patient needing a pulse generator replacement. Permanent pacemaker implantation in dextrocardia can be challenging because of the distorted anatomy. Use of a technique employing angiography to delineate chamber anatomy and relationship can assist the operator during such difficult PPIs. The medium- and long-term survival after a successful pacemaker implantation in dextrocardia is favourable. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2014. For permissions please email: journals.permissions@oup.com.

  13. Rhabdomyosarcoma associated with the lead wire of a pacemaker generator implant.

    Science.gov (United States)

    Thieman Mankin, Kelley M; Dunbar, Mark D; Toplon, David; Ginn, Pamela; Maisenbacher, Herbert W; Risselada, Marije

    2014-06-01

    An 11-year-old female spayed Labrador Retriever was presented for a draining, painful subcutaneous mass palpated over a previously implanted pacemaker generator. Infection was suspected and the mass was removed surgically. On cut surface, the mass was friable and mottled tan to brown with firm pale tan nodules, surrounding the pacemaker lead wire adjacent to the pacemaker generator. Cytologic interpretation of impression smears was consistent with a sarcoma, and suggestive of a rhabdomyosarcoma due to the presence of strap-like cells. On histopathologic examination, a highly invasive nodular mass surrounded the pacemaker lead, composed of pleomorphic round, spindle and strap cells, and multinucleated giant cells. The population exhibited microscopic invasion into the deep portion of the fibrous capsule surrounding the pacemaker generator. There were tumor emboli within small to medium subcutaneous veins adjacent to the mass. Immunohistochemically, the neoplastic cells stained positive for α-sarcomeric actin and vimentin, and negative for α-smooth muscle actin, consistent with a rhabdomyosarcoma arising at the site of the pacemaker generator. To our knowledge, this is the first report of a rhabdomyosarcoma associated with the lead wire of a pacemaker generator in a dog. © 2014 American Society for Veterinary Clinical Pathology and European Society for Veterinary Clinical Pathology.

  14. Evaluation of Death among the Patients Undergoing Permanent Pacemaker Implantation: A Competing Risks Analysis.

    Science.gov (United States)

    Ghaem, Haleh; Ghorbani, Mohammad; Zare Dorniani, Samira

    2017-06-01

    Permanent artificial pacemaker is one of the important therapies for treatment of cardiac conduction system problems. The present study aimed to determine the association between some predictive variables and all-cause and cause-specific mortality in the patients who had undergone pacemaker implantation. This study was conducted on 1207 patients who had undergone permanent pacemaker implantation in the hospitals affiliated with Shiraz University of Medical Sciences, Iran, from Mar 2002 to Mar 2012. The variables that existed in the patients' medical records included sex, diabetes mellitus, obesity, cerebrovascular accident, cardiomegaly, smoking, hypertension, ischemic heart disease, congenital heart disease, sick sinus syndrome, and atrial fibrillation. Competing risks model was used to assess the association between the predictive variables and cause-specific (i.e., cardiac and vascular) mortality. The patients' mean age was 66.32±17.92 yr (70.62±14.45 yr in the patients with single-chamber pacemakers vs. 61.91±17.69 yr in those with two-chamber pacemakers) ( P pacemaker decreased this risk. Obesity increased the risk of cardiac death, and diabetes mellitus and heart valve disease increased the risk of vascular death. The variables predicting mortality in all-cause model were completely different from those in cause-specific model. Moreover, death in such patients may occur due to reasons other than pacemaker. Therefore, future studies, particularly prospective ones, are recommended to use competing risks models.

  15. Survival time with pacemaker implantation for dogs diagnosed with persistent atrial standstill.

    Science.gov (United States)

    Cervenec, R M; Stauthammer, C D; Fine, D M; Kellihan, H B; Scansen, B A

    2017-06-01

    To evaluate survival time in dogs with persistent atrial standstill after pacemaker implantation and to compare the survival times for cardiac-related vs. non-cardiac deaths. Secondary objectives were to evaluate the effects of breed and the presence of congestive heart failure (CHF) at the time of diagnosis on survival time. Twenty dogs with persistent atrial standstill and pacemaker implantation. Medical records were searched to identify dogs diagnosed with persistent atrial standstill based on electrocardiogram that underwent pacemaker implantation. Survival after pacemaker implantation was analyzed using the Kaplan-Meier method. The median survival time after pacemaker implantation for all-cause mortality was 866 days. There was no significant difference (p=0.573) in median survival time for cardiac (506 days) vs. non-cardiac deaths (400 days). The presence of CHF at the time of diagnosis did not affect the survival time (P=0.854). No difference in median survival time was noted between breeds (P=0.126). Dogs with persistent atrial standstill have a median survival time of 866 days with pacemaker implantation, though a wide range of survival times was observed. There was no difference in the median survival time for dogs with cardiac-related deaths and those without. Patient breed and the presence of CHF before pacemaker implantation did not affect median survival time. Copyright © 2017 Elsevier B.V. All rights reserved.

  16. Outcome and management of pacemaker-induced superior vena cava syndrome.

    Science.gov (United States)

    Fu, Hai-Xia; Huang, Xin-Miao; Zhong, Li; Osborn, Michael J; Bjarnason, Haraldur; Mulpuru, Siva; Zhao, Xian-Xian; Friedman, Paul A; Cha, Yong-Mei

    2014-11-01

    We aimed to determine the long-term outcomes of percutaneous lead extraction and stent placement in patients with pacemaker-induced superior vena cava (SVC) syndrome. The study retrospectively screened patients who underwent lead extraction followed by central vein stent implantation at Mayo Clinic (Rochester, MN, USA), from January 2005 to December 2012, to identify the patients with pacemaker-induced SVC syndrome. Demographic, clinical, and follow-up characteristics of those patients were collected from electronic medical records. Six cases were identified. The mean (standard deviation) age was 56 (15) years (male, 67%). All patients had permanent dual-chamber pacemakers, with a mean 11-year history of pacemaker placement. The entire device system was explanted in five patients; one patient had a 21-year-old pacemaker lead that could not be removed. Eight stents were implanted in six patients: five patients had one stent, one patient had three. A new pacemaker system was reimplanted through the stented vein in five patients. Technical success was achieved in all patients, without any complication. Symptoms rapidly resolved in all patients after stent deployment. The mean follow-up duration was 48 months (range, 10-100 months). Three patients remained symptom free. Reintervention with percutaneous balloon venoplasty was successful in three patients with symptom recurrence. Percutaneous stent implantation after lead removal followed by reimplantation of leads is a feasible alternative therapy for pacemaker-induced SVC syndrome, although some cases may require repeat intervention. ©2014 Wiley Periodicals, Inc.

  17. Evaluation of cumulative effects of MR imaging on pacemaker systems at 1.5 Tesla.

    Science.gov (United States)

    Naehle, Claas P; Zeijlemaker, Volkert; Thomas, Daniel; Meyer, Carsten; Strach, Katharina; Fimmers, Rolf; Schild, Hans; Sommer, Torsten

    2009-12-01

    The purpose of this study was to evaluate possible cumulative effects of repeated magnetic resonance imaging (MRI) examinations on pacemaker systems in patients with cardiac pacemakers. The records of pacemaker patients who underwent repetitive MRI examinations in our institution were reviewed to identify patients who underwent two or more MRI examinations at 1.5T of any anatomical region. Using these criteria, a total of 47 patients who underwent a total 171 MRI examinations were identified and included in this study. Institutional Review Board approval for all pacemaker investigations was obtained. Written informed consent was obtained from all patients. Pacemakers were interrogated immediately before and after MR imaging, and after 3 months, including measurement of pacing capture threshold (PCT), lead impedance (LI), and battery voltage (BV). PCT, LI, and BV were analyzed for changes dependant on the number of MRI exams performed. Mean changes over time and changes between first and last pacemaker interrogation of PCT, LI, and BV were calculated. A statistically significant (P < 0.05), but clinically irrelevant trend for decrease in PCT and BV was found. No significant or clinically relevant changes in LI were observed. In this first study, no clinically relevant, cumulative changes in PCT, LI, or BV could be detected in PM patients who underwent two or more MRI examinations. However, a careful benefit/risk evaluation, among other MRI- and pacemaker-related safety precautions, remains mandatory, as clinically relevant alterations to the PM system cannot be excluded by all means.

  18. Placement Of Cardiac PacemaKEr Trial (POCKET) - rationale and design: a randomized controlled trial.

    Science.gov (United States)

    Magnusson, Peter; Wennström, Leo; Kastberg, Robert; Liv, Per

    2017-01-01

    A pacemaker system consists of one or two leads connected to a device that is implanted into a pocket formed just below the collarbone. This pocket is typically subcutaneous, that is, located just above the pectoral fascia. Even though the size of pacemakers has decreased markedly, complications due to superficial implants do occur. An alternative technique would be intramuscular placement of the pacemaker device, but there are no randomized controlled trials (RCTs) to support this approach, which is the rationale for the Placement Of Cardiac PacemaKEr Trial (POCKET). The aim is to study if intramuscular is superior to subcutaneous placement of a pacemaker pocket. In October 2016, we started to enroll 200 consecutive patients with an indication for bradycardia pacemaker implantation. Patients are randomized to random block sizes, stratified by age group (cut-off: 65 years) and sex, and then randomized to either subcutaneous or intramuscular implant. A concealed allocation procedure is employed, using sequentially numbered, sealed envelopes. Pocket site is blinded to the patient and in all subsequent care. The primary endpoint is patient overall satisfaction with the pocket location at 24 months as measured using a visual analog scale (VAS) 0-10. Secondary endpoints are: complications, patient-reported satisfaction at 1, 12, and 24 months (overall satisfaction, pain, discomfort, degree of unsightly appearance, movement problems, and sleep problems due to device). POCKET is a prospective interventional RCT designed to evaluate if intramuscular is superior to subcutaneous placement of a bradycardia pacemaker during a two-year follow-up.

  19. Cognitive processes and attitudes in bipolar disorder: a study into personality, dysfunctional attitudes and attention bias in patients with bipolar disorder and their relatives.

    Science.gov (United States)

    Jabben, Nienke; Arts, Baer; Jongen, Ellen M M; Smulders, Fren T Y; van Os, Jim; Krabbendam, Lydia

    2012-12-20

    Research in cognitive processes and attitudes in bipolar disorder is scarce and has provided mixed findings, possibly due to differences in current mood state. It is unclear whether alterations in cognitive processes and attitudes are only related to the depressive mood states of bipolar patients or also represent a vulnerability marker for the development of future (depressive) episodes. This was investigated in the current study. Both implicit (attentional bias for emotional words) and explicit (dysfunctional attitudes and personality characteristics) measures of cognitive processes and attitudes were assessed in 77 bipolar patients with varying levels of depressive symptoms (depressed=17, euthymic n=60), their healthy first-degree relatives (n=39) and a healthy control group (n=61). Analyses of variance were used to investigate differences between groups. Mildly depressed patients with bipolar disorder demonstrated an attentional bias away from positive emotional words and showed increased dysfunctional attitudes and higher levels of neuroticism. Euthymic patients were largely comparable to healthy controls and only differed from controls in higher levels of neuroticism. Relatives were similar to controls on all measures, although they significantly differed from bipolar patients in displaying less neuroticism and more extraversion. No firm conclusions regarding causality can be drawn from the associations that were found between cognitive processes and attitudes and the evolution of mood symptoms in bipolar disorder. Alterations in cognitive processes and attitudes in bipolar patients appear to be mostly related to the expression of mood symptomatology rather than to the vulnerability for bipolar disorder. Copyright © 2012 Elsevier B.V. All rights reserved.

  20. Pacemaker reed switch behavior in 0.5, 1.5, and 3.0 Tesla magnetic resonance imaging units: are reed switches always closed in strong magnetic fields?

    Science.gov (United States)

    Luechinger, Roger; Duru, Firat; Zeijlemaker, Volkert A; Scheidegger, Markus B; Boesiger, Peter; Candinas, Reto

    2002-10-01

    MRI is established as an important diagnostic tool in medicine. However, the presence of a cardiac pacemaker is usually regarded as a contraindication for MRI due to safety reasons. The aim of this study was to investigate the state of a pacemaker reed switch in different orientations and positions in the main magnetic field of 0.5-, 1.5-, and 3.0-T MRI scanners. Reed switches used in current pacemakers and ICDs were tested in 0.5-, 1.5-, and 3.0-T MRI scanners. The closure of isolated reed switches was evaluated for different orientations and positions relative to the main magnetic field. The field strengths to close and open the reed switch and the orientation dependency of the closed state inside the main magnetic field were investigated. The measurements were repeated using two intact pacemakers to evaluate the potential influence of the other magnetic components, like the battery. If the reed switches were oriented parallel to the magnetic fields, they closed at 1.0 +/- 0.2 mT and opened at 0.7 +/- 0.2 mT. Two different reed switch behaviors were observed at different magnetic field strengths. In low magnetic fields ( 200 mT), the reed switches opened in 50% of all tested orientations. No difference between the three scanners could be demonstrated. The reed switches showed the same behavior whether they were isolated or an integral part of the pacemakers. The reed switch in a pacemaker or an ICD does not necessarily remain closed in strong magnetic fields at 0.5, 1.5, or 3.0 T and the state of the reed switch may not be predictable with certainty in clinical situations.

  1. The role of psychological factors in bipolar disorder: prospective relationships between cognitive style, coping style and symptom expression.

    Science.gov (United States)

    Fletcher, Kathryn; Parker, Gordon; Manicavasagar, Vijaya

    2014-04-01

    Psychological factors contribute to bipolar disorder illness course, representing targets for psychological intervention. Research to date has focused on bipolar I disorder, extrapolating results to bipolar II disorder. The current study addresses this discrepancy by exploring cognitive and coping styles in patients diagnosed with bipolar I or II disorder. Participants were recruited from the Sydney-based Black Dog Institute. Diagnoses were derived via the MINI International Neuropsychiatric Interview. Baseline cognitive and coping style measures were completed, and mood symptoms assessed over a 6-month period. Clinician-rated mood status was assessed at follow-up to determine the predictive utility of cognitive and coping styles. The follow-up sample comprised 151 participants. Differential relationships between cognitive style, coping styles and mood symptoms emerged across the bipolar sub-types. Some key differences were that a broader set of negative cognitive styles were associated with bipolar II depression symptoms; while few relationships were observed between coping styles and bipolar II symptoms. Differences in cognitive and coping style relationships with symptom expression across bipolar I and II disorder may provide clinicians with fruitful guides for directing treatment interventions when relevant maladaptive styles are observed. Further exploration of differences in cognitive and coping styles in bipolar I and II disorder is warranted.

  2. Bipolar one diode-one resistor integration for high-density resistive memory applications.

    Science.gov (United States)

    Li, Yingtao; Lv, Hangbing; Liu, Qi; Long, Shibing; Wang, Ming; Xie, Hongwei; Zhang, Kangwei; Huo, Zongliang; Liu, Ming

    2013-06-07

    Different from conventional unipolar-type 1D-1R RRAM devices, a bipolar-type 1D-1R memory device concept is proposed and successfully demonstrated by the integration of Ni/TiOx/Ti diode and Pt/HfO2/Cu bipolar RRAM cell to suppress the undesired sneak current in a cross-point array. The bipolar 1D-1R memory device not only achieves self-compliance resistive switching characteristics by the reverse bias current of the Ni/TiOx/Ti diode, but also exhibits excellent bipolar resistive switching characteristics such as uniform switching, satisfactory data retention, and excellent scalability, which give it high potentiality for high-density integrated nonvolatile memory applications.

  3. Vertical bipolar charge plasma transistor with buried metal layer.

    Science.gov (United States)

    Nadda, Kanika; Kumar, M Jagadesh

    2015-01-19

    A self-aligned vertical Bipolar Charge Plasma Transistor (V-BCPT) with a buried metal layer between undoped silicon and buried oxide of the silicon-on-insulator substrate, is reported in this paper. Using two-dimensional device simulation, the electrical performance of the proposed device is evaluated in detail. Our simulation results demonstrate that the V-BCPT not only has very high current gain but also exhibits high BVCEO · f(T) product making it highly suitable for mixed signal high speed circuits. The proposed device structure is also suitable for realizing doping-less bipolar charge plasma transistor using compound semiconductors such as GaAs, SiC with low thermal budgets. The device is also immune to non-ideal current crowding effects cropping up at high current densities.

  4. A review of factors associated with greater likelihood of suicide attempts and suicide deaths in bipolar disorder: Part II of a report of the International Society for Bipolar Disorders Task Force on Suicide in Bipolar Disorder

    Science.gov (United States)

    Schaffer, Ayal; Isometsä, Erkki T; Azorin, Jean-Michel; Cassidy, Frederick; Goldstein, Tina; Rihmer, Zoltán; Sinyor, Mark; Tondo, Leonardo; Moreno, Doris H; Turecki, Gustavo; Reis, Catherine; Kessing, Lars Vedel; Ha, Kyooseob; Weizman, Abraham; Beautrais, Annette; Chou, Yuan-Hwa; Diazgranados, Nancy; Levitt, Anthony J; Zarate, Carlos A; Yatham, Lakshmi

    2018-01-01

    Objectives Many factors influence the likelihood of suicide attempts or deaths in persons with bipolar disorder. One key aim of the International Society for Bipolar Disorders Task Force on Suicide was to summarize the available literature on the presence and magnitude of effect of these factors. Methods A systematic review of studies published from 1 January 1980 to 30 May 2014 identified using keywords ‘bipolar disorder’ and ‘suicide attempts or suicide’. This specific paper examined all reports on factors putatively associated with suicide attempts or suicide deaths in bipolar disorder samples. Factors were subcategorized into: (1) sociodemographics, (2) clinical characteristics of bipolar disorder, (3) comorbidities, and (4) other clinical variables. Results We identified 141 studies that examined how 20 specific factors influenced the likelihood of suicide attempts or deaths. While the level of evidence and degree of confluence varied across factors, there was at least one study that found an effect for each of the following factors: sex, age, race, marital status, religious affiliation, age of illness onset, duration of illness, bipolar disorder subtype, polarity of first episode, polarity of current/recent episode, predominant polarity, mood episode characteristics, psychosis, psychiatric comorbidity, personality characteristics, sexual dysfunction, first-degree family history of suicide or mood disorders, past suicide attempts, early life trauma, and psychosocial precipitants. Conclusion There is a wealth of data on factors that influence the likelihood of suicide attempts and suicide deaths in people with bipolar disorder. Given the heterogeneity of study samples and designs, further research is needed to replicate and determine the magnitude of effect of most of these factors. This approach can ultimately lead to enhanced risk stratification for patients with bipolar disorder. PMID:26175498

  5. Ventricular oversensing of atrial electrical activity that inhibits VVI pacemaker and causes syncope

    Directory of Open Access Journals (Sweden)

    Elibet Chávez González

    2015-10-01

    Full Text Available Far-field oversensing of atrial electrical activity caused by a VVI pacemaker is a rare phenomenon; however, it may have serious clinical consequences. It has several causes and its timely identification may avoid a possible ventricular asystole. This article reports the case of a 72-year-old male who had a Biotronik Axios SR pacemaker implanted, in VVIR mode, six years ago, due to blocked atrial fibrillation. He suffered syncope due to pacemaker inhibition caused by ventricular oversensing of atrial electrical activity.

  6. W/kit gene required for interstitial cells of Cajal and for intestinal pacemaker activity

    DEFF Research Database (Denmark)

    Huizinga, J D; Thuneberg, L; Klüppel, M

    1995-01-01

    The pacemaker activity in the mammalian gut is responsible for generating anally propagating phasic contractions. The cellular basis for this intrinsic activity is unknown. The smooth muscle cells of the external muscle layers and the innervated cellular network of interstitial cells of Cajal......, which is closely associated with the external muscle layers of the mammalian gut, have both been proposed to stimulate pacemaker activity. The interstitial cells of Cajal were identified in the last century but their developmental origin and function have remained unclear. Here we show...... of Cajal associated with Auerbach's nerve plexus and intestinal pacemaker activity....

  7. Structural and functional changes in the somatosensory cortex in euthymic females with bipolar disorder.

    Science.gov (United States)

    Minuzzi, Luciano; Syan, Sabrina K; Smith, Mara; Hall, Alexander; Hall, Geoffrey Bc; Frey, Benicio N

    2017-12-01

    Current evidence from neuroimaging data suggests possible dysfunction of the fronto-striatal-limbic circuits in individuals with bipolar disorder. Somatosensory cortical function has been implicated in emotional recognition, risk-taking and affective responses through sensory modalities. This study investigates anatomy and function of the somatosensory cortex in euthymic bipolar women. In total, 68 right-handed euthymic women (bipolar disorder = 32 and healthy controls = 36) between 16 and 45 years of age underwent high-resolution anatomical and functional magnetic resonance imaging during the mid-follicular menstrual phase. The somatosensory cortex was used as a seed region for resting-state functional connectivity analysis. Voxel-based morphometry was used to evaluate somatosensory cortical gray matter volume between groups. We found increased resting-state functional connectivity between the somatosensory cortex and insular cortex, inferior prefrontal gyrus and frontal orbital cortex in euthymic bipolar disorder subjects compared to healthy controls. Voxel-based morphometry analysis showed decreased gray matter in the left somatosensory cortex in the bipolar disorder group. Whole-brain voxel-based morphometry analysis controlled by age did not reveal any additional significant difference between groups. This study is the first to date to evaluate anatomy and function of the somatosensory cortex in a well-characterized sample of euthymic bipolar disorder females. Anatomical and functional changes in the somatosensory cortex in this population might contribute to the pathophysiology of bipolar disorder.

  8. Access to Pharmacotherapy Amongst Women with Bipolar Disorder during Pregnancy: a Preliminary Study.

    Science.gov (United States)

    Byatt, Nancy; Cox, Lucille; Moore Simas, Tiffany A; Biebel, Kathleen; Sankaran, Padma; Swartz, Holly A; Weinreb, Linda

    2018-03-01

    Bipolar disorder among pregnant women has deleterious effects on birth and child outcomes and is currently under-detected, not addressed effectively, or exacerbated through inappropriate treatment. The goal of this study was to identify perspectives of pregnant and postpartum women with bipolar disorder on barriers and facilitators to psychiatric treatment during pregnancy. In-depth interviews were conducted with pregnant and postpartum women who scored ≥ 10 on the Edinburgh Postnatal Depression Scale and met DSM-IV criteria for bipolar disorder I, II or not otherwise specified using the Mini International Neuropsychiatric Interview version 5.0. Interviews were transcribed, and resulting data were analyzed using a grounded theory approach to identify barriers and facilitators to bipolar disorder treatment access in pregnancy. Participant identified barriers included perception that psychiatric providers lack training and experience in the treatment of psychiatric illness during pregnancy, are reluctant to treat bipolar disorder among pregnant women, and believe that pharmacotherapy is not needed for psychiatric illness during pregnancy. Facilitators included participants' perception that providers' acknowledge risks associated with untreated or undertreated psychiatric illness during pregnancy and provide psycho-education about the risks, benefits and alternatives to pharmacotherapy. Psychiatric providers are critically important to the treatment of bipolar disorder and need knowledge and skills necessary to provide care during the perinatal period. Advancing psychiatric providers' knowledge/skills may improve access to pharmacotherapy for pregnant women with bipolar disorder.

  9. Predicting bipolar disorder on the basis of phenomenology: implications for prevention and early intervention.

    Science.gov (United States)

    Malhi, Gin S; Bargh, Danielle M; Coulston, Carissa M; Das, Pritha; Berk, Michael

    2014-08-01

    Bipolar disorder is a multifaceted illness and there is often a substantial delay between the first onset of symptoms and diagnosis. Early detection has the potential to curtail illness progression and disorder-associated burden but it requires a clear understanding of the initial bipolar prodrome. This article summarizes the phenomenology of bipolar disorder with an emphasis on the initial prodrome, the evolution of the illness, and the implications for prevention and early intervention. A literature review was undertaken using Medline, Web of Science, and a hand search of relevant literature using keywords (e.g., phenomenology, initial or early symptoms, risk factors, and predictors/prediction). Findings from the literature were reviewed and synthesized and have been put into a clinical context. Bipolar disorder is a recurrent, persistent, and disabling illness that typically develops in adolescence or early adulthood. The literature search yielded 28 articles, in which mood lability, nonspecific, non-mood symptoms, and cyclothymic temperament were the most cited prodromal features. A small number of key prospective studies have provided evidence in support of an initial bipolar prodrome; however, methodological differences across studies have prohibited its clear delineation. It is, therefore, not currently possible to anticipate those who will develop bipolar disorder solely on the basis of early phenomenology. Accurate characterization of the bipolar disorder prodrome through high-quality, prospective research studies with adequate control groups will ultimately facilitate prompt and accurate diagnosis. © 2013 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  10. [Comorbidity of eating disorders and bipolar affective disorders].

    Science.gov (United States)

    Kamińska, Katarzyna; Rybakowski, Filip

    2006-01-01

    Eating disorders--anorexia nervosa, bulimia nervosa and eating disorders not otherwise specified (EDNOS) occur usually in young females. The significant pathogenic differences between patients who only restrict food, and patients with binge eating and compensatory behaviours, such as vomiting and purging were described. The prevalence of bipolar affective disorders--especially bipolar II and bipolar spectrum disorders (BS) may reach 5% in the general population. About half of the depressive episodes are associated with a "mild" bipolar disorder, and such a diagnosis is suggested by impulsivity and mood-instability. Previously, majority of research on the comorbidity between eating and affective disorders focused on depressive symptomatology, however difficulties in the reliable assessment of hypomania may obfuscate the estimation of the co-occurrence of eating disorders with BS. Epidemiological studies suggest the association between BS and eating disorders with binge episodes (bulimia nervosa, anorexia- bulimic type and EDNOS with binge episodes). Co-occurrence of such disorders with depressive symptoms probably suggests the diagnosis of BS, not recurrent depression. Bulimic behaviours, impulsivity and affective disorders might be related to the impairment of the serotonergic neurotransmission, which may result from the genetic vulnerability and early life trauma. Currently, the first-line pharmacological treatment of co-occurring eating disorders with binge episodes and BS are selective serotonin reuptake inhibitors. However in some cases, the use of mood-stabilising agents as monotherapy or in combination with serotonergic drugs may be helpful.

  11. Social cognition and functional capacity in bipolar disorder and schizophrenia.

    Science.gov (United States)

    Thaler, Nicholas S; Sutton, Griffin P; Allen, Daniel N

    2014-12-15

    Social cognition is a functionally relevant predictor of capacity in schizophrenia (SZ), though research concerning its value for bipolar disorder (BD) is limited. The current investigation examined the relationship between two social cognitive factors and functional capacity in bipolar disorder. This study included 48 individuals with bipolar disorder (24 with psychotic features) and 30 patients with schizophrenia. Multiple regression controlling for estimated IQ scores was used to assess the predictive value of social cognitive factors on the UCSD Performance-Based Functional Skills Assessment (UPSA). Results found that for the bipolar with psychosis and schizophrenia groups, the social/emotion processing factor predicted the UPSA. The theory of mind factor only predicted the UPSA for the schizophrenia group.. Findings support the clinical utility of evaluating emotion processing in individuals with a history of psychosis. For BD, theory of mind may be better explained by a generalized cognitive deficit. In contrast, social/emotion processing may be linked to distinct neurobiological processes associated with psychosis. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  12. [BIPOLAR DISORDER AS A MULTI-SYSTEM ILLNESS].

    Science.gov (United States)

    Fenchel, Daphna; Levkovitz, Yechiel; Kotler, Moshe

    2017-12-01

    Bipolar disorder is a chronic condition, characterized by high distress in patients and high suicide rates (30%). Most patients suffer from medical and other psychiatric comorbidities, which worsen the psychiatric symptoms and decrease the likelihood of remission. More than 70% of bipolar patients have cardio-metabolic symptoms, with higher rates compared to other psychiatric disorders. Cardiovascular disease is the major cause of high mortality rates in these patients, with 1.5-2 fold increased risk of mortality, compared to the general population without psychiatric symptoms. The rates of cardiovascular risk factors and their resulting increased mortality rates are similar to those found in schizophrenia. In addition to cardio-metabolic conditions, 50% of patients with bipolar disorder suffer from other medical symptoms, which are also associated with worse outcomes. Therefore, the current perspective is that bipolar disorder is not only a psychiatric disorder, but rather a multi-system illness, affecting the entire body. The optimal treatment for these patients should include diagnosis, monitoring and treatment of both psychiatric and physical symptoms, which would improve their prognosis.

  13. Pacemakers in large arrays of oscillators with nonlocal coupling

    Science.gov (United States)

    Jaramillo, Gabriela; Scheel, Arnd

    2016-02-01

    We model pacemaker effects of an algebraically localized heterogeneity in a 1 dimensional array of oscillators with nonlocal coupling. We assume the oscillators obey simple phase dynamics and that the array is large enough so that it can be approximated by a continuous nonlocal evolution equation. We concentrate on the case of heterogeneities with positive average and show that steady solutions to the nonlocal problem exist. In particular, we show that these heterogeneities act as a wave source. This effect is not possible in 3 dimensional systems, such as the complex Ginzburg-Landau equation, where the wavenumber of weak sources decays at infinity. To obtain our results we use a series of isomorphisms to relate the nonlocal problem to the viscous eikonal equation. We then use Fredholm properties of the Laplace operator in Kondratiev spaces to obtain solutions to the eikonal equation, and by extension to the nonlocal problem.

  14. Unusual Treatment of Pacemaker Pocket Infection: A Case Report

    Directory of Open Access Journals (Sweden)

    Ali Kazemisaeed

    2010-12-01

    Full Text Available Pocket infection of a cardiac device is usually treated by removing the device and re-implanting it in a new site after complete treatment of the infection. This report illustrates a complicated case of pocket infection in the wake of the implantation of a permanent pacemaker (cardiac resynchronization therapy. The patient was treated conservatively through daily irrigation and dressing, broad-spectrum antibiotics, and debridement without the device being removed; the generator was kept out of the pocket for 5 weeks and then re-implanted in the same location successfully. The method of treatment presented herein can be of value, not least in the elderly population who might experience life-threatening events following the replacement of their cardiac devices.

  15. Bipolar polygenic loading and bipolar spectrum features in major depressive disorder

    NARCIS (Netherlands)

    Wiste, Anna; Robinson, Elise B.; Milaneschi, Yuri; Meier, Sandra; Ripke, Stephan; Clements, Caitlin C.; Fitzmaurice, Garrett M.; Rietschel, Marcella; Penninx, Brenda W.; Smoller, Jordan W.; Perlis, Roy H.

    Objectives Family and genetic studies indicate overlapping liability for major depressive disorder and bipolar disorder. The purpose of the present study was to determine whether this shared genetic liability influences clinical presentation. Methods A polygenic risk score for bipolar disorder,

  16. A PROSPECTIVE STUDY COMPARING MONOPOLAR AND BIPOLAR TRANSURETHRAL RESECTION OF PROSTATE

    Directory of Open Access Journals (Sweden)

    L. N. Raju

    2016-07-01

    Full Text Available In the past few years, the bipolar technique of resecting the prostate has become available worldwide, and currently alongside other minimally invasive techniques, especially different laser modalities, challenges the monopolar transurethral resection of the prostate (TURP as being the gold standard in treating benign prostatic hyperplasia (BPH. The proposed advantages of bipolar resection are improved haemostasis, better intraoperative visualisation, use of saline as an irrigant, which reduces the risk for TUR syndrome, shorter catheterisation time and reduced hospital stay. This study compares monopolar and bipolar TURP with respect to safety, efficacy and complications. MATERIALS AND METHODS This study was performed in the Department of Urology, Rajarajeswari Medical College and Hospital, Bangalore from March 2015 to March 2016 after ethics committee clearance. Fifty patients with bladder outlet obstruction due to BPH were randomised into two groups (the first managed by standard monopolar TURP and the second managed by bipolar TURP. RESULTS Resection and operative time is comparable in both groups. Volume of the irrigation fluid used was less in Bipolar group, but this difference was statistically insignificant. In Bipolar TURP, change in Serum Na levels postoperatively is less compared to monopolar group and this difference is statistically significant. Postoperative catheter duration was found same in both groups. Although postoperative hospital stay and patients requiring blood transfusion was less in bipolar group, this difference was not found significant statistically. Postoperative complication rate in bipolar group was less but it was not statistically significant. CONCLUSION Bipolar TURP has an equivalent complication profile; however, the elimination of a patient return electrode pad and toxicity from hypo-osmolar irrigation fluids may provide an extra level of patient safety. Longer followup is needed to determine if this

  17. Latest generation of unipolar and bipolar steroid eluting leads: long-term comparison of electrical performance in atrium and ventricles.

    Science.gov (United States)

    Cornacchia, D; Fabbri, M; Puglisi, A; Moracchini, P; Bernasconi, M; Nastasi, M; Menozzi, C; Mascioli, G; Marotta, T; de Seta, F

    2000-07-01

    One hundred and seventy-three patients, mean age 74 years permanently paced with 123 atrial (53 unipolar, 70 bipolar) and 143 ventricular (73 unipolar, 70 bipolar) pacing leads were included in this study. The pacing leads were recent generation low surface area steroid eluting leads from one manufacturer: leads with silicone and polyurethane insulation were studied, and they were combined with generations of one pacemaker family from the same manufacturer permitting identical measurements to be made over a follow-up of 2 years. Pacing threshold was measured using pulse duration at a fixed voltage of 1.5 V: peak to peak P and R wave amplitude and pacing impedance at 2.5 V and 0.5 ms were all measured using the manufacturer's standard programmer. Although many significant differences, in the parameters measures, existed between atrium and ventricle and unipolar and bipolar configurations, none was felt to be of clinical significance. These data permit the physician to choose the lead type with regard to sensing performance and long-term lead integrity.

  18. A novel non invasive measurement of hemodynamic parameters: Comparison of single-chamber ventricular and dual-chamber pacemaker

    Directory of Open Access Journals (Sweden)

    Ingrid M. Pardede

    2008-03-01

    Full Text Available We carried out a cross sectional study to analyze hemodynamic parameters of single-chamber ventricular pacemaker compared with dual-chamber pacemaker by using thoracic electrical bioimpedance monitoring method (Physio Flow™ - a novel simple non-invasive measurement. A total of 48 consecutive outpatients comprised of 27 single chamber pacemaker and 21 dual chamber were analyzed. We measured cardiac parameters: heart rate, stroke volume index, cardiac output index, estimated ejection fraction, end diastolic volume, early diastolic function ratio, thoracic fluid index, and systemic parameters: left cardiac work index and systemic vascular resistance index. Baseline characteristic and pacemaker indication were similar in both groups. Cardiac parameters assessment revealed no significant difference between single-chamber pacemaker and dual-chamber pacemaker in heart rate, stroke volume index, cardiac index, estimated ejection fraction, end-diastolic volume, thoracic fluid index. There was significantly higher early diastolic function ratio in single-chamber pacemaker compared to dual-chamber pacemaker: 92% (10.2-187.7% vs. 100.6% (48.7-403.2%; p=0.006. Systemic parameters assessment revealed significantly higher left cardiac work index in single-chamber group than dual-chamber group 4.9 kg.m/m² (2.8-7.6 kg.m/m² vs. 4.3 kg.m/m² (2.9-7.2 kg.m/m²; p=0.004. There was no significant difference on systemic vascular resistance in single-chamber compared to dual-chamber pacemaker. Single-chamber ventricular pacemaker provides similar stroke volume, cardiac output and left cardiac work, compared to dual-chamber pacemaker. A non-invasive hemodynamic measurement using thoracic electrical bioimpedance is feasible for permanent pacemaker outpatients. (Med J Indones 2008; 17: 25-32Keywords: Permanent pacemaker, single chamber, dual chamber, thoracic electrical bioimpedance, hemodynamic parameter

  19. Analysis of a five year experience of permanent pacemaker implantation at a Nigerian Teaching Hospital: need for a national database

    Science.gov (United States)

    Falase, Bode; Sanusi, Michael; Johnson, Adeyemi; Akinrinlola, Fola; Ajayi, Reina; Oke, David

    2013-01-01

    Introduction Permanent pacemaker implantation is available in Nigeria. There is however no national registry or framework for pacemaker data collection. A pacemaker database has been developed in our institution and the results are analyzed in this study. Methods The study period was between January 2008 and December 2012. Patient data was extracted from a prospectively maintained database which was designed to include the fields of the European pacemaker patient identification code. Results Of the 51 pacemaker implants done, there were 29 males (56.9%) and 22 females (43.1%). Mean age was 68.2±12.7 years. Clinical indications were syncopal attacks in 25 patients (49%), dizzy spells in 15 patients (29.4%), bradycardia with no symptoms in 10 patients (17.7%) and dyspnoea in 2 patients (3.9%). The ECG diagnosis was complete heart block in 27 patients (53%), second degree heart block in 19 patients (37.2%) and sick sinus syndrome with bradycardia in 5 patients (9.8%). Pacemaker modes used were ventricular pacing in 29 patients (56.9%) and dual chamber pacing in 22 patients (43.1%). Files have been closed in 20 patients (39.2%) and 31 patients (60.8%) are still being followed up with median follow up of 26 months, median of 5 visits and 282 pacemaker checks done. Complications seen during follow up were 3 lead displacements (5.9%), 3 pacemaker infections (5.9%), 2 pacemaker pocket erosions (3.9%), and 1 pacemaker related death (2%). There were 5 non-pacemaker related deaths (9.8%). Conclusion Pacemaker data has been maintained for 5 years. We urge other implanting institutions in Nigeria to maintain similar databases and work towards establishment of a national pacemaker registry. PMID:24498465

  20. Psychosocial aspects and mental health in children after permanent pacemaker implantation

    DEFF Research Database (Denmark)

    Andersen, C; Hørder, K; Kristensen, L

    1994-01-01

    The present study was designed to evaluate the psychosocial status and the mental health of children receiving a permanent pacemaker during childhood. Nineteen children under the age of 19 years had a permanent pacemaker implanted. Contact was established to 15 of these patients, 7 girls and 8 boys......, and they were given a child-psychiatric evaluation consisting of a semi-structured and a child-psychiatric interview. The psychological interview used intelligence tests and the Draw-A-Person test as well as the Rorschach test. The patients had had their pacemakers during an average of 6.7 years (range 3......-14). Generally the psychological condition was strained in 7 families, in which psychiatric and social therapy had been necessary. The children's intelligence was within normal ranges, average IQ being 110 (range 80-135). The children had abnormal body image related to the pacemaker. Adults virtually incorporate...

  1. Machines in our hearts: the cardiac pacemaker, the implantable defibrillator, and American health care

    National Research Council Canada - National Science Library

    Jeffrey, Kirk

    2001-01-01

    ... A Device Reliability, Qualification Tests, and Improvements 291 APPENDIX B Number of Implantations 294 APPENDIX C ICHD Pacemaker Identification Code 296 Abbreviations 297 Notes 299 Bibliographical N...

  2. An Unusual Cause of Transient Ischemic Attack in a Patient with Pacemaker

    Directory of Open Access Journals (Sweden)

    Jagadeesh Kumar Kalavakunta

    2014-01-01

    Full Text Available Pacemaker lead malposition in various locations has been described in the literature. Lead malposition in left ventricle is a rare and an underdiagnosed complication. We present a 77-year-old man with history of atrial fibrillation and pacemaker placement who was admitted for transient ischemic attack. He was on aspirin, beta blocker, and warfarin with subtherapeutic international normalized ratio. His paced electrocardiogram showed right bundle-branch block, rather than the typical pattern of left bundle-branch block, suggesting pacemaker lead malposition. Further, his chest X-ray and echocardiogram confirmed the pacemaker lead position in the left ventricle instead of right ventricle. He refused surgical removal of the lead and we increased his warfarin dose. Diagnosis of lead malposition in left ventricle, though easy to identify in echocardiogram, requires high index of clinical suspicion. In asymptomatic patients, surgical removal may be deferred for treatment with lifelong anticoagulation.

  3. Magnetic Resonance Imaging in a Patient with a Dual Chamber Pacemaker

    Science.gov (United States)

    Millar, Lynne Martina; Robinson, Andrew George; O'Flaherty, Maurice Thomas; Eames, Niall; Johnston, Nicola; Heyburn, Gary

    2010-01-01

    Having a pacemaker has been seen an absolute contraindication to having an MRI scan. This has become increasingly difficult in clinical practice as insertion of pacemakers and implantable cardiac defibrillators is at an all time high. Here we outline a case where a 71-year-old male patient with a permanent pacemaker needed to have an MRI scan to ascertain the aetiology of his condition and help guide further management. Given this clinical dilemma, an emergency clinical ethics consultation was arranged. As a result the patient underwent an MRI scan safely under controlled conditions with a consultant cardiologist and radiologist present. The results of the MRI scan were then able to tailor further treatment. This case highlights that in certain conditions an MRI can be performed in patients with permanent pacemakers and outlines the role of clinical ethics committees in complex medical decision making. PMID:21331383

  4. Sikkerhed af magnetisk resonans-skanning hos patienter med pacemaker og implanterbar defibrillator

    DEFF Research Database (Denmark)

    Al-Sabagh, Kifah Hekmat; Christensen, Britta Ege; Thøgersen, Anna Margrethe

    2010-01-01

    INTRODUCTION: The presence of a cardiac implantable device is ICD considered an absolute contraindication to magnetic resonance imaging (MRI). The purpose of this study was to evaluate the safety of performing MRI in patients with cardiac pacemakers and ICDs that had a compelling clinical need...... for MRI examination. MATERIAL AND METHODS: During a period of nine years we have included 65 patients with cardiac devices (60 pacemakers and five ICDs) who underwent a total of 73 MRI examinations at 1.5 T. All pacemakers were reprogrammed before MRI to asynchronous mode to avoid MRI-induced inhibition...... safely in 63 patients. Inhibition of pacemaker output was observed in one patient and induction of ventricular fibrillation was observed in another with ICD. A significant increase in PCT was rare and only detected in 1% of all electrodes. CONCLUSION: MRI can be performed safely in patients...

  5. 76 FR 48058 - Effective Date of Requirement for Premarket Approval for Cardiovascular Permanent Pacemaker...

    Science.gov (United States)

    2011-08-08

    ...-documented case histories conducted by qualified experts, and reports of significant human experience with a... case reports, random experience, reports lacking sufficient details to permit scientific evaluation... Approval for Cardiovascular Permanent Pacemaker Electrode AGENCY: Food and Drug Administration, HHS. ACTION...

  6. The Improvement of the Atrial Flutter Rhythm upon the Removal of the Infected Permanent Pacemaker Lead

    Directory of Open Access Journals (Sweden)

    Ali Azari

    2015-06-01

    Full Text Available Pacemaker infection has multiple risk factors. Its presentation is most often similar to infected endocarditis and the diagnosis is made through studying blood cultures. Transesophageal echocardiography can confirm the diagnosis. The most common microorganisms are staphylococcus speciesis. As a matter of fact, complete pacemaker removal appears to be the only definite treatment. We presented a case of infected pacemaker lead which was firstly referred with fever and nephritic syndrome. She had intermittent atrial flutterrhythm. Therefore, a total infected pacemaker system was removed under cardiopulmonary bypass support. Yet, the lead was firmly attached to the septal leaflet of tricuspid valve while leaflet repair was needed. As a result, atrial flutter rhythm was converted into sinus rhythm after an incidental interruption of the macroreentrant circuit in the process of the tricuspid leaflet surgery.

  7. Magnetic Resonance Imaging in a Patient with a Dual Chamber Pacemaker

    Directory of Open Access Journals (Sweden)

    Lynne Martina Millar

    2010-01-01

    Full Text Available Having a pacemaker has been seen an absolute contraindication to having an MRI scan. This has become increasingly difficult in clinical practice as insertion of pacemakers and implantable cardiac defibrillators is at an all time high. Here we outline a case where a 71-year-old male patient with a permanent pacemaker needed to have an MRI scan to ascertain the aetiology of his condition and help guide further management. Given this clinical dilemma, an emergency clinical ethics consultation was arranged. As a result the patient underwent an MRI scan safely under controlled conditions with a consultant cardiologist and radiologist present. The results of the MRI scan were then able to tailor further treatment. This case highlights that in certain conditions an MRI can be performed in patients with permanent pacemakers and outlines the role of clinical ethics committees in complex medical decision making.

  8. Obesity and bipolar disorder: synergistic neurotoxic effects?

    Science.gov (United States)

    Liu, Celina S; Carvalho, André F; Mansur, Rodrigo B; McIntyre, Roger S

    2013-11-01

    Bipolar disorder (BD) is a disabling and chronic neuropsychiatric disorder that is typified by a complex illness presentation, episode recurrence and by its frequent association with psychiatric and medical comorbidities. Over the past decade, obesity has emerged as one of many comorbidities generating substantial concern in the BD population due to important prognostic implications. This comprehensive review details the bidirectional relationship between obesity and BD as evidenced by alterations in the structure and function of the central nervous system, in addition to greater depressive recurrence, cognitive dysfunction and risk of suicidality. Drawing on current research results, this article presents several putative mechanisms underlying the synergistic toxic effects and provides a framework for future treatment options for the obesity-BD comorbidity. There is a need for more large-scale prospective studies to investigate the bidirectional relationships between obesity and BD.

  9. SU-E-I-42: Normalized Embryo/fetus Doses for Fluoroscopically Guided Pacemaker Implantation Procedures Calculated Using a Monte Carlo Technique

    Energy Technology Data Exchange (ETDEWEB)

    Damilakis, J; Stratakis, J; Solomou, G [University of Crete, Heraklion (Greece)

    2014-06-01

    Purpose: It is well known that pacemaker implantation is sometimes needed in pregnant patients with symptomatic bradycardia. To our knowledge, there is no reported experience regarding radiation doses to the unborn child resulting from fluoroscopy during pacemaker implantation. The purpose of the current study was to develop a method for estimating embryo/fetus dose from fluoroscopically guided pacemaker implantation procedures performed on pregnant patients during all trimesters of gestation. Methods: The Monte Carlo N-Particle (MCNP) radiation transport code was employed in this study. Three mathematical anthropomorphic phantoms representing the average pregnant patient at the first, second and third trimesters of gestation were generated using Bodybuilder software (White Rock science, White Rock, NM). The normalized embryo/fetus dose from the posteroanterior (PA), the 30° left-anterior oblique (LAO) and the 30° right-anterior oblique (RAO) projections were calculated for a wide range of kVp (50–120 kVp) and total filtration values (2.5–9.0 mm Al). Results: The results consist of radiation doses normalized to a) entrance skin dose (ESD) and b) dose area product (DAP) so that the dose to the unborn child from any fluoroscopic technique and x-ray device used can be calculated. ESD normalized doses ranged from 0.008 (PA, first trimester) to 2.519 μGy/mGy (RAO, third trimester). DAP normalized doses ranged from 0.051 (PA, first trimester) to 12.852 μGy/Gycm2 (RAO, third trimester). Conclusion: Embryo/fetus doses from fluoroscopically guided pacemaker implantation procedures performed on pregnant patients during all stages of gestation can be estimated using the method developed in this study. This study was supported by the Greek Ministry of Education and Religious Affairs, General Secretariat for Research and Technology, Operational Program ‘Education and Lifelong Learning’, ARISTIA (Research project: CONCERT)

  10. [New conduction disturbances and pacemaker indications after CoreValve® transcatheter aortic valve replacement. Incidence and follow up in a single center experience].

    Science.gov (United States)

    Aversa, Eliana; Muratore, Claudio A; Nemesio, M Laura; Tentori, Maria Cristina; Payaslian, Miguel

    2015-01-01

    Transcatheter aortic valve implantation (TAVI) is currently reserved for patients with symptomatic aortic stenosis and high surgical risk. One major limiting factor related to TAVI procedural complications is conduction abnormalities and the need for permanent pacemaker implantation. Evaluate the incidence of new conduction disturbances and pacemaker indications in patients with TAVI CoreValve® prosthesis (Medtronic Inc. Minneapolis, Minnesota, United States). We included 28 patients, mean age 80 years. ECG parameters were evaluated previous and after implantation. All patients were monitorized during TAVI. Follow up Holter monitoring was performed at one, 6 and 12 months after the procedure and we also evaluated telemetry of implanted pacemaker. In previous ECG we found 7 patients had right bundle branch block and 7 patients had left bundle brunch block (LBBB). The post implant ECG showed 7 new LBBB: 3 during valvuloplasty and 4 on the end of it. Six patients required pacemaker implantation for permanent or paroxysmal complete AV block (CAVB). At one year follow up, 3 patients with LBBB during valvuloplasty had a normal ECG, one still had LBBB and one an asymptomatic CAVB found in Holter monitoring. Conduction abnormalities are frequent after CoreValve® aortic valve prosthesis implantation. The incidence of new LBBB was 25%. CAVB during or post TAVI require PM implantation. New LBBB may need a closer follow up because in a 3% of the cases it may progress to CAVB. Copyright © 2014 Instituto Nacional de Cardiología Ignacio Chávez. Published by Masson Doyma México S.A. All rights reserved.

  11. Unsplit bipolar pulse forming line

    Science.gov (United States)

    Rhodes, Mark A [Pleasanton, CA

    2011-05-24

    A bipolar pulse forming transmission line module and system for linear induction accelerators having first, second, third, and fourth planar conductors which form a sequentially arranged interleaved stack having opposing first and second ends, with dielectric layers between the conductors. The first and second planar conductors are connected to each other at the first end, and the first and fourth planar conductors are connected to each other at the second end via a shorting plate. The third planar conductor is electrically connectable to a high voltage source, and an internal switch functions to short at the first end a high voltage from the third planar conductor to the fourth planar conductor to produce a bipolar pulse at the acceleration axis with a zero net time integral. Improved access to the switch is enabled by an aperture through the shorting plate and the proximity of the aperture to the switch.

  12. Interference of apex locator, pulp tester and diathermy on pacemaker function

    OpenAIRE

    Narayanan Sriman; V Prabhakar; J S Bhuvaneswaran; N Subha

    2015-01-01

    Aim: The purpose of this study was to evaluate the effects of three electronic apex locators (EAL), electric pulp tester (EPT) and diathermy on pacemaker function in vitro. Materials and Methods: Three EALs: Root ZX (J. Morita Co., Tustin, CA, U.S.A.), Propex (Dentsply), Mini Apex locator (SybronEndo, Anaheim, CA, USA), EPT (Parkell pulp vitality tester Farmingdale, NY, USA) and Diathermy (Neomed 250 B) were tested for any interference with one pacemaker (A medtronic kappa KVDD901-serial ...

  13. A Fully Implantable Pacemaker for the Mouse: From Battery to Wireless Power

    Science.gov (United States)

    Zellmer, Erik R.; Weinheimer, Carla J.; MacEwan, Matthew R.; Cui, Sophia X.; Nerbonne, Jeanne M.; Efimov, Igor R.

    2013-01-01

    Animal models have become a popular platform for the investigation of the molecular and systemic mechanisms of pathological cardiovascular physiology. Chronic pacing studies with implantable pacemakers in large animals have led to useful models of heart failure and atrial fibrillation. Unfortunately, molecular and genetic studies in these large animal models are often prohibitively expensive or not available. Conversely, the mouse is an excellent species for studying molecular mechanisms of cardiovascular disease through genetic engineering. However, the large size of available pacemakers does not lend itself to chronic pacing in mice. Here, we present the design for a novel, fully implantable wireless-powered pacemaker for mice capable of long-term (>30 days) pacing. This design is compared to a traditional battery-powered pacemaker to demonstrate critical advantages achieved through wireless inductive power transfer and control. Battery-powered and wireless-powered pacemakers were fabricated from standard electronic components in our laboratory. Mice (n = 24) were implanted with endocardial, battery-powered devices (n = 14) and epicardial, wireless-powered devices (n = 10). Wireless-powered devices were associated with reduced implant mortality and more reliable device function compared to battery-powered devices. Eight of 14 (57.1%) mice implanted with battery-powered pacemakers died following device implantation compared to 1 of 10 (10%) mice implanted with wireless-powered pacemakers. Moreover, device function was achieved for 30 days with the wireless-powered device compared to 6 days with the battery-powered device. The wireless-powered pacemaker system presented herein will allow electrophysiology studies in numerous genetically engineered mouse models as well as rapid pacing-induced heart failure and atrial arrhythmia in mice. PMID:24194832

  14. Tilt-table testing of patients with pacemaker and recurrent syncope

    DEFF Research Database (Denmark)

    Nielsen, Christian E. Haarmark; Kanters, Jørgen K; Mehlsen, Jesper

    2016-01-01

    The diagnosis of recurrent syncope in patients with pacemakers (PM) is quite challenging and the etiology of syncope is often multifactorial. To portray the mechanism of syncope in PM patients, we report the results of head-up tilt table testing (HUT) in a series of patients with PM, originally...... with pacemakers has a high diagnostic yield. Although, the majority of patients had a vasodepressor or orthostatic hypotensive response, cardioinhibitory response leading to syncope was also seen....

  15. Frequency of pacemaker malfunction associated with monopolar electrosurgery during pulse generator replacement or upgrade surgery.

    Science.gov (United States)

    Lin, Yun; Melby, Daniel P; Krishnan, Balaji; Adabag, Selcuk; Tholakanahalli, Venkatakrishna; Li, Jian-Ming

    2017-08-01

    The aim of this study is to investigate the frequency of electrosurgery-related pacemaker malfunction. A retrospective study was conducted to investigate electrosurgery-related pacemaker malfunction in consecutive patients undergoing pulse generator (PG) replacement or upgrade from two large hospitals in Minneapolis, MN between January 2011 and January 2014. The occurrence of this pacemaker malfunction was then studied by using MAUDE database for all four major device vendors. A total of 1398 consecutive patients from 2 large tertiary referral centers in Minneapolis, MN undergoing PG replacement or upgrade surgery were retrospectively studied. Four patients (0.3% of all patients), all with pacemakers from St Jude Medical (2.8%, 4 of 142) had output failure or inappropriately low pacing rate below 30 bpm during electrosurgery, despite being programmed in an asynchronous mode. During the same period, 1174 cases of pacemaker malfunctions were reported on the same models in MAUDE database, 37 of which (3.2%) were electrosurgery-related. Twenty-four cases (65%) had output failure or inappropriate low pacing rate. The distribution of adverse events was loss of pacing (59.5%), reversion to backup pacing (32.4%), inappropriate low pacing rate (5.4%), and ventricular fibrillation (2.7%). The majority of these (78.5%) occurred during PG replacement at ERI or upgrade surgery. No electrosurgery-related malfunction was found in MAUDE database on 862 pacemaker malfunction cases during the same period from other vendors. Electrosurgery during PG replacement or upgrade surgery can trigger output failure or inappropriate low pacing rate in certain models of modern pacemakers. Cautions should be taken for pacemaker-dependent patients.

  16. Course of Subthreshold Bipolar Disorder in Youth: Diagnostic Progression from Bipolar Disorder Not Otherwise Specified

    Science.gov (United States)

    Axelson, David A.; Birmaher, Boris; Strober, Michael A.; Goldstein, Benjamin I.; Ha, Wonho; Gill, Mary Kay; Goldstein, Tina R.; Yen, Shirley; Hower, Heather; Hunt, Jeffrey I.; Liao, Fangzi; Iyengar, Satish; Dickstein, Daniel; Kim, Eunice; Ryan, Neal D.; Frankel, Erica; Keller, Martin B.

    2011-01-01

    Objective: To determine the rate of diagnostic conversion from an operationalized diagnosis of bipolar disorder not otherwise specified (BP-NOS) to bipolar I disorder (BP-I) or bipolar II disorder (BP-II) in youth over prospective follow-up and to identify factors associated with conversion. Method: Subjects were 140 children and adolescents…

  17. GABAergic neuroactive steroids: a new frontier in bipolar disorders?

    Directory of Open Access Journals (Sweden)

    Carta Mauro Giovanni

    2012-12-01

    Full Text Available Abstract Neurosteroids are synthesized in the brain and modulate brain excitability. There is increasing evidence of their sedative, anesthetic and antiseizure properties, as well as their influence on mood. Currently neurosteroids are classified as pregnane neurosteroids (allopregnanolone and allotetrahydrodeoxycorticosterone, androstane neurosteroids (androstanediol and etiocholanone or sulfated neurosteroids (pregnenolone sulfate and dehydroepiandrosterone sulfate. Both preclinical and clinical findings indicate that progesterone derivative neurosteroids such as allopregnanolone and allotetrahydrodeoxycorticosterone play a role in mood disorders. Clozapine and olanzapine, which were shown to be effective in stabilizing bipolar disorder, elevate pregnenolone levels in rat hippocampus, cerebral cortex, and serum. In lithium-treated mice, the blood levels of allopregnanolone and pregnenolone were elevated compared to control levels. Women diagnosed with bipolar disorder typically show symptomatic exacerbation in relation to the menstrual cycle, and show vulnerability to the onset or recurrence of mood disorders immediately after giving birth, when the levels of neurosteroid derivatives of progesterone drop. Whereas in women who had recovered from bipolar disorder, the plasma concentration of allopregnanolone was elevated compared to either healthy controls or women with major depressive disorder during the premenstrual period. During depressive episodes, blood level of allopregnanolone is low. Treatment with fluoxetine tends to stabilize the levels of neurosteroids in depression. These findings converge to suggest that these steroids have significant mood-stabilizing effect. This hypothesis is consistent with the observation that a number of anticonvulsants are effective therapies for bipolar disorder, a finding also consistent with the antiseizure properties of neurosteroids. Further exploration of action of neuroactive steroids is likely to

  18. Bipolar (spectrum) disorder and mood stabilization: standing at the crossroads?

    OpenAIRE

    De Fruyt, Jurgen; Demyttenaere, Koen

    2007-01-01

    Diagnosis and treatment of bipolar disorder has long been a neglected discipline. Recent years have shown an upsurge in bipolar research. When compared to major depressive disorder, bipolar research still remains limited and more expert based than evidence based. In bipolar diagnosis the focus is shifting from classic mania to bipolar depression and hypomania. There is a search for bipolar signatures in symptoms and course of major depressive episodes. The criteria for hypomania are softened,...

  19. [Bipolar disorders in DSM-5].

    Science.gov (United States)

    Severus, E; Bauer, M

    2014-05-01

    In spring 2013 the fifth edition of the Diagnostic and Statistical Manual of Mental Disorders (DSM-5) edited by the American Psychiatric Association was published. The DSM-5 has also brought some important changes regarding bipolar disorders. The goal of this manuscript is to review the novelties in DSM-5 and to evaluate the implications of these changes. The diagnostic criteria as well as the additional remarks provided in the running text of DSM-5 were carefully appraised. For the first time diagnostic criteria are provided for disorders which up to now have been considered as subthreshold bipolar disorders. Furthermore, mixed episodes were eliminated and instead a mixed specifier was introduced. An increase in goal-directed activity/energy is now one of the obligatory symptoms for a (hypo)manic episode. Diagnostic guidance is provided as to when a (hypo)manic episode that has developed during treatment with an antidepressant has to be judged to be causally related to antidepressants and when this episode has only occurred coincidentally with antidepressant use. While some of the novelties are clearly useful, e.g. addition of increased goal-directed activity/energy as obligatory symptom for (hypo)manic episodes, this remains to be demonstrated for others, such as the definition of various subthreshold bipolar disorders.

  20. The prevalence and correlates of alcohol use disorder amongst bipolar patients in a hospital setting, Malaysia.

    Science.gov (United States)

    Yee, Hway Ann; Loh, Huai Seng; Ng, Chong Guan

    2013-10-01

    To determine the prevalence of alcohol-use disorder and associated correlates amongst bipolar patients in a university hospital in Malaysia. In this cross-sectional study, a total of 121 bipolar disorder patients were included. Their alcohol use disorders were assessed with the Mini International Neuropsychiatric Interview (plus version) and the Addiction Severity Index-Lite-Clinical Factors version. The number of lifetime hospitalizations and the survival days (the number of days between the last discharge and the most current readmission) were calculated. The prevalence of alcohol-use disorder amongst bipolar patients was 18.2%. Indian ethnicity was the only demographic factor that was statistically associated with alcohol-use disorder (p suicidal attempt (p Malaysia. Since alcohol-use disorder, as well as the potential interactions with the course of the disorder, is highly prevalent amongst bipolar patients, alcohol use should be addressed in these patients.

  1. Rethinking emotion: cognitive reappraisal is an effective positive and negative emotion regulation strategy in bipolar disorder.

    Science.gov (United States)

    Gruber, June; Hay, Aleena C; Gross, James J

    2014-04-01

    Bipolar disorder involves difficulties with emotion regulation, yet the precise nature of these emotion regulatory difficulties is unclear. The current study examined whether individuals with remitted bipolar I disorder (n = 23) and healthy controls (n = 23) differ in their ability to use one effective and common form of emotion regulation, cognitive reappraisal. Positive, negative, and neutral films were used to elicit emotion, and participants were cued to watch the film carefully (i.e., uninstructed condition) or reappraise while measures of affect, behavior, and psychophysiology were obtained. Results showed that reappraisal was associated with reductions in emotion reactivity across subjective (i.e., positive and negative affect), behavioral (i.e., positive facial displays), and physiological (i.e., skin conductance) response domains across all participants. Results suggest that reappraisal may be an effective regulation strategy for both negative and positive emotion across both healthy adults and individuals with bipolar disorder. Discussion focuses on clinical and treatment implications for bipolar disorder.

  2. Doping To Reduce Base Resistances Of Bipolar Transistors

    Science.gov (United States)

    Lin, True-Lon

    1991-01-01

    Modified doping profile proposed to reduce base resistance of bipolar transistors. A p/p+ base-doping profile reduces base resistance without reducing current gain. Proposed low/high base-doping profile realized by such low-temperature deposition techniques as molecular-beam epitaxy, ultra-high-vacuum chemical-vapor deposition, and limited-reaction epitaxy. Produces desired doping profiles without excessive diffusion of dopant.

  3. Development of pacemaker properties and rhythmogenic mechanisms in the mouse embryonic respiratory network

    Science.gov (United States)

    Chevalier, Marc; Toporikova, Natalia; Simmers, John; Thoby-Brisson, Muriel

    2016-01-01

    Breathing is a vital rhythmic behavior generated by hindbrain neuronal circuitry, including the preBötzinger complex network (preBötC) that controls inspiration. The emergence of preBötC network activity during prenatal development has been described, but little is known regarding inspiratory neurons expressing pacemaker properties at embryonic stages. Here, we combined calcium imaging and electrophysiological recordings in mouse embryo brainstem slices together with computational modeling to reveal the existence of heterogeneous pacemaker oscillatory properties relying on distinct combinations of burst-generating INaP and ICAN conductances. The respective proportion of the different inspiratory pacemaker subtypes changes during prenatal development. Concomitantly, network rhythmogenesis switches from a purely INaP/ICAN-dependent mechanism at E16.5 to a combined pacemaker/network-driven process at E18.5. Our results provide the first description of pacemaker bursting properties in embryonic preBötC neurons and indicate that network rhythmogenesis undergoes important changes during prenatal development through alterations in both circuit properties and the biophysical characteristics of pacemaker neurons. DOI: http://dx.doi.org/10.7554/eLife.16125.001 PMID:27434668

  4. The East Asian Summer Monsoon in pacemaker experiments driven by ENSO

    Science.gov (United States)

    Ding, Hui; Greatbatch, Richard J.; Lu, Jian; Cash, Ben

    2015-03-01

    The variability of the East Asian summer monsoon (EASM) is studied using a pacemaker technique driven by ENSO in an atmospheric general circulation model (AGCM) coupled to a slab mixed layer model. In the pacemaker experiments, sea surface temperature (SST) is constrained to observations in the eastern equatorial Pacific through a q- flux that measures the contribution of ocean dynamics to SST variability, while the AGCM is coupled to the slab model. An ensemble of pacemaker experiments is analyzed using a multivariate EOF analysis to identify the two major modes of variability of the EASM. The results show that the pacemaker experiments simulate a substantial amount (around 45 %) of the variability of the first mode (the Pacific-Japan pattern) in ERA40 from 1979 to 1999. Different from previous work, the pacemaker experiments also simulate a large part (25 %) of the variability of the second mode, related to rainfall variability over northern China. Furthermore, we find that the lower (850 hPa) and the upper (200 hPa) tropospheric circulation of the first mode display the same degree of reproducibility whereas only the lower part of the second mode is reproducible. The basis for the success of the pacemaker experiments is the ability of the experiments to reproduce the observed relationship between El Niño Southern Oscillation (ENSO) and the EASM.

  5. Biological pacemaker created by minimally invasive somatic reprogramming in pigs with complete heart block

    Science.gov (United States)

    Hu, Yu-Feng; Dawkins, James Frederick; Cho, Hee Cheol; Marbán, Eduardo; Cingolani, Eugenio

    2016-01-01

    Somatic reprogramming by reexpression of the embryonic transcription factor T-box 18 (TBX18) converts cardiomyocytes into pacemaker cells. We hypothesized that this could be a viable therapeutic avenue for pacemaker-dependent patients afflicted with device-related complications, and therefore tested whether adenoviral TBX18 gene transfer could create biological pacemaker activity in vivo in a large-animal model of complete heart block. Biological pacemaker activity, originating from the intramyocardial injection site, was evident in TBX18-transduced animals starting at day 2 and persisted for the duration of the study (14 days) with minimal backup electronic pacemaker use. Relative to controls transduced with a reporter gene, TBX18-transduced animals exhibited enhanced autonomic responses and physiologically superior chronotropic support of physical activity. Induced sinoatrial node cells could be identified by their distinctive morphology at the site of injection in TBX18-transduced animals, but not in controls. No local or systemic safety concerns arose. Thus, minimally invasive TBX18 gene transfer creates physiologically relevant pacemaker activity in complete heart block, providing evidence for therapeutic somatic reprogramming in a clinically relevant disease model. PMID:25031269

  6. Electromagnetic immunity of implantable pacemakers exposed to wi-fi devices.

    Science.gov (United States)

    Mattei, Eugenio; Censi, Federica; Triventi, Michele; Calcagnini, Giovanni

    2014-10-01

    The purpose of this study is to evaluate the potential for electromagnetic interference (EMI) and to assess the immunity level of implantable pacemakers (PM) when exposed to the radiofrequency (RF) field generated by Wi-Fi devices. Ten PM from five manufacturers, representative of what today is implanted in patients, have been tested in vitro and exposed to the signal generated by a Wi-Fi transmitter. An exposure setup that reproduces the actual IEEE 802.11b/g protocol has been designed and used during the tests. The system is able to amplify the Wi-Fi signal and transmits at power levels higher than those allowed by current international regulation. Such approach allows one to obtain, in case of no EMI, a safety margin for PM exposed to Wi-Fi signals, which otherwise cannot be derived if using commercial Wi-Fi equipment. The results of this study mitigate concerns about using Wi-Fi devices close to PM: none of the PM tested exhibit any degradation of their performance, even when exposed to RF field levels five times higher than those allowed by current international regulation (20 W EIRP). In conclusion, Wi-Fi devices do not pose risks of EMI to implantable PM. The immunity level of modern PM is much higher than the transmitting power of RF devices operating at 2.4 GHz.

  7. An actigraphy study investigating sleep in bipolar I patients, unaffected siblings and controls.

    Science.gov (United States)

    Verkooijen, Sanne; van Bergen, Annet H; Knapen, Stefan E; Vreeker, Annabel; Abramovic, Lucija; Pagani, Lucia; Jung, Yoon; Riemersma-van der Lek, Rixt; Schoevers, Robert A; Takahashi, Joseph S; Kahn, René S; Boks, Marco P M; Ophoff, Roel A

    2017-01-15

    Disturbances in sleep and waking patterns are highly prevalent during mood episodes in bipolar disorder. The question remains whether these disturbances persist during phases of euthymia and whether they are heritable traits of bipolar disorder. The current study investigates objective sleep measures in a large sample of bipolar I patients, non-affected siblings and controls. A total of 107 bipolar disorder I patients, 74 non-affected siblings, and 80 controls were included. Sleep was measured with actigraphy over the course of 14 days. Seven sleep parameters were analyzed for group differences and their relationship with age at onset, number of episodes and psychotic symptoms using linear mixed model analysis to account for family dependencies. Patients had a longer sleep duration and later time of sleep offset compared to the non-affected siblings but these differences were entirely attributable to differences in mood symptoms. We found no difference between patients and controls or siblings and controls when the analyses were restricted to euthymic patients. None of the bipolar illness characteristics were associated with sleep. Medication use was not taken into account which may have influenced our findings and controls were younger compared to non-affected siblings. In the largest study to date, our findings suggest that recovered bipolar I patients and their siblings do not experience clinically significant sleep disturbances. Sleep disturbances are primarily a reflection of current mood state, but are unrelated to the course of the disorder. Copyright © 2016 Elsevier B.V. All rights reserved.

  8. Methodological recommendations for cognition trials in bipolar disorder by the International Society for Bipolar Disorders Targeting Cognition Task Force.

    Science.gov (United States)

    Miskowiak, K W; Burdick, K E; Martinez-Aran, A; Bonnin, C M; Bowie, C R; Carvalho, A F; Gallagher, P; Lafer, B; López-Jaramillo, C; Sumiyoshi, T; McIntyre, R S; Schaffer, A; Porter, R J; Torres, I J; Yatham, L N; Young, A H; Kessing, L V; Vieta, E

    2017-12-01

    To aid the development of treatment for cognitive impairment in bipolar disorder, the International Society for Bipolar Disorders (ISBD) convened a task force to create a consensus-based guidance paper for the methodology and design of cognition trials in bipolar disorder. The task force was launched in September 2016, consisting of 18 international experts from nine countries. A series of methodological issues were identified based on literature review and expert opinion. The issues were discussed and expanded upon in an initial face-to-face meeting, telephone conference call and email exchanges. Based upon these exchanges, recommendations were achieved. Key methodological challenges are: lack of consensus on how to screen for entry into cognitive treatment trials, define cognitive impairment, track efficacy, assess functional implications, and manage mood symptoms and concomitant medication. Task force recommendations are to: (i) enrich trials with objectively measured cognitively impaired patients; (ii) generally select a broad cognitive composite score as the primary outcome and a functional measure as a key secondary outcome; and (iii) include remitted or partly remitted patients. It is strongly encouraged that trials exclude patients with current substance or alcohol use disorders, neurological disease or unstable medical illness, and keep non-study medications stable. Additional methodological considerations include neuroimaging assessments, targeting of treatments to illness stage and using a multimodal approach. This ISBD task force guidance paper provides the first consensus-based recommendations for cognition trials in bipolar disorder. Adherence to these recommendations will likely improve the sensitivity in detecting treatment efficacy in future trials and increase comparability between studies. © 2017 The Authors Bipolar Disorders Published by John Wiley & Sons Ltd.

  9. Bipolar mixed features - Results from the comparative effectiveness for bipolar disorder (Bipolar CHOICE) study.

    Science.gov (United States)

    Tohen, Mauricio; Gold, Alexandra K; Sylvia, Louisa G; Montana, Rebecca E; McElroy, Susan L; Thase, Michael E; Rabideau, Dustin J; Nierenberg, Andrew A; Reilly-Harrington, Noreen A; Friedman, Edward S; Shelton, Richard C; Bowden, Charles L; Singh, Vivek; Deckersbach, Thilo; Ketter, Terence A; Calabrese, Joseph R; Bobo, William V; McInnis, Melvin G

    2017-08-01

    DSM-5 changed the criteria from DSM-IV for mixed features in mood disorder episodes to include non-overlapping symptoms of depression and hypomania/mania. It is unknown if, by changing these criteria, the same group would qualify for mixed features. We assessed how those meeting DSM-5 criteria for mixed features compare to those meeting DSM-IV criteria. We analyzed data from 482 adult bipolar patients in Bipolar CHOICE, a randomized comparative effectiveness trial. Bipolar diagnoses were confirmed through the MINI International Neuropsychiatric Interview (MINI). Presence and severity of mood symptoms were collected with the Bipolar Inventory of Symptoms Scale (BISS) and linked to DSM-5 and DSM-IV mixed features criteria. Baseline demographics and clinical variables were compared between mood episode groups using ANOVA for continuous variables and chi-square tests for categorical variables. At baseline, the frequency of DSM-IV mixed episodes diagnoses obtained with the MINI was 17% and with the BISS was 20%. Using DSM-5 criteria, 9% of participants met criteria for hypomania/mania with mixed features and 12% met criteria for a depressive episode with mixed features. Symptom severity was also associated with increased mixed features with a high rate of mixed features in patients with mania/hypomania (63.8%) relative to those with depression (8.0%). Data on mixed features were collected at baseline only and thus do not reflect potential patterns in mixed features within this sample across the study duration. The DSM-5 narrower, non-overlapping definition of mixed episodes resulted in fewer patients who met mixed criteria compared to DSM-IV. Copyright © 2017. Published by Elsevier B.V.

  10. [Thinking organization and defense mechanisms in bipolar disorders. Clinical and psychopathological study on bipolar I and bipolar II].

    Science.gov (United States)

    Lo Baido, Rosa; Di Blasi, Marie; Alfano, Pietro; Audino, Palma; Bellavia, Carmela; Blando, Anna Antonia; Merendino, Adelaide; Messina, Rossana; Poma, Maria Luisa; La Grutta, Sabina

    2013-01-01

    The aim of this research is to explore the psychical functioning in bipolar I or bipolar II disorder people through the analysis and comparison of their thought styles and defense patterns. 29 bipolar I and bipolar II people afferent to Palermo University Policlinical Psychriatic Hospital Department were selected during the whole 2009-2010 year. The following tests were administred: Wechsler Adult Intelligent Scale-R (WAIS-R) in order to measure the general cognitive function; Defense Mechanisms Inventory (DMI) in order to measure defense patterns. Afterwards, the results of the two tests were analysed and compared. Bipolar disorder people use cognitive mechanisms and defense strategies that are very different from standard population. Bipolar I subjects show both wider and more serious cognitive deterioration and stricter defense mechanisms than bipolar II subjects. Generally bipolar patients show an immature personality based on archaic mechanisms that can be found in all the spheres of their personality: emotions, cognition, Ego-strength, adaptability to reality. The peculiar achieved cognitive and defense profile leads to important considerations about how psychological strategies can contribute to use "bespoke" treatments for these patients.

  11. Use of an active fixation lead and a subpectoral pacemaker pocket may not avoid Twiddler′s syndrome

    Directory of Open Access Journals (Sweden)

    Floris E A Udink ten Cate

    2012-01-01

    Full Text Available Manipulation of a pacemaker with consequent malfunction of the device has been called Twiddler′s syndrome. Use of active-fixation leads and subpectoral pacemaker pockets has been considered to help in avoiding this problem. We describe a child in whom twiddling was not prevented despite implantation of a lumenless atrial lead and insertion of the pacemaker generator in a subpectoral pocket.

  12. Prevalence of cognitive impairment in major depression and bipolar disorder.

    Science.gov (United States)

    Douglas, Katie M; Gallagher, Peter; Robinson, Lucy J; Carter, Janet D; McIntosh, Virginia Vw; Frampton, Christopher Ma; Watson, Stuart; Young, Allan H; Ferrier, I Nicol; Porter, Richard J

    2018-01-18

    The current study examines prevalence of cognitive impairment in four mood disorder samples, using four definitions of impairment. The impact of premorbid IQ on prevalence was examined, and the influence of treatment response. Samples were: (i) 58 inpatients in a current severe depressive episode (unipolar or bipolar), (ii) 69 unmedicated outpatients in a mild to moderate depressive episode (unipolar or bipolar), (iii) 56 outpatients with bipolar disorder, in a depressive episode, and (iv) 63 outpatients with bipolar disorder, currently euthymic. Cognitive assessment was conducted after treatment in Studies 1 (6 weeks of antidepressant treatment commenced on admission) and 2 (16-week course of cognitive behaviour therapy or schema therapy), allowing the impact of treatment response to be assessed. All mood disorder samples were compared with healthy control groups. The prevalence of cognitive impairment was highest for the inpatient depression sample (Study 1), and lowest for the outpatient depression sample (Study 2). Substantial variability in rates was observed depending on the definition of impairment used. Correcting cognitive performance for premorbid IQ had a significant impact on the prevalence of cognitive impairment in the inpatient depression sample. There was minimal evidence that treatment response impacted on prevalence of cognitive impairment, except in the domain of psychomotor speed in inpatients. As interventions aiming to improve cognitive outcomes in mood disorders receive increasing research focus, the issue of setting a cut-off level of cognitive impairment for screening purposes becomes a priority. This analysis demonstrates important differences in samples likely to be recruited depending on the definition of cognitive impairment and begins to examine the importance of premorbid IQ in determining who is impaired. © 2018 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  13. Toward complementary ionic circuits: the npn ion bipolar junction transistor.

    Science.gov (United States)

    Tybrandt, Klas; Gabrielsson, Erik O; Berggren, Magnus

    2011-07-06

    Many biomolecules are charged and may therefore be transported with ionic currents. As a step toward addressable ionic delivery circuits, we report on the development of a npn ion bipolar junction transistor (npn-IBJT) as an active control element of anionic currents in general, and specifically, demonstrate actively modulated delivery of the neurotransmitter glutamic acid. The functional materials of this transistor are ion exchange layers and conjugated polymers. The npn-IBJT shows stable transistor characteristics over extensive time of operation and ion current switch times below 10 s. Our results promise complementary chemical circuits similar to the electronic equivalence, which has proven invaluable in conventional electronic applications.

  14. Poorer sustained attention in bipolar I than bipolar II disorder

    Directory of Open Access Journals (Sweden)

    Chen Shih-Heng

    2010-02-01

    Full Text Available Abstract Background Nearly all information processing during cognitive processing takes place during periods of sustained attention. Sustained attention deficit is among the most commonly reported impairments in bipolar disorder (BP. The majority of previous studies have only focused on bipolar I disorder (BP I, owing to underdiagnosis or misdiagnosis of bipolar II disorder (BP II. With the refinement of the bipolar spectrum paradigm, the goal of this study was to compare the sustained attention of interepisode patients with BP I to those with BP II. Methods In all, 51 interepisode BP patients (22 with BP I and 29 with BP II and 20 healthy controls participated in this study. The severity of psychiatric symptoms was assessed by the 17-item Hamilton Depression Rating Scale and the Young Mania Rating Scale. All participants undertook Conners' Continuous Performance Test II (CPT-II to evaluate sustained attention. Results After controlling for the severity of symptoms, age and years of education, BP I patients had a significantly longer reaction times (F(2,68 = 7.648, P = 0.001, worse detectability (d' values (F(2,68 = 6.313, P = 0.003 and more commission errors (F(2,68 = 6.182, P = 0.004 than BP II patients and healthy controls. BP II patients and controls scored significantly higher than BP I patients for d' (F = 6.313, P = 0.003. No significant difference was found among the three groups in omission errors and no significant correlations were observed between CPT-II performance and clinical characteristics in the three groups. Conclusions These findings suggested that impairments in sustained attention might be more representative of BP I than BP II after controlling for the severity of symptoms, age, years of education and reaction time on the attentional test. A longitudinal follow-up study design with a larger sample size might be needed to provide more information on chronological sustained attention deficit in BP patients, and to illustrate

  15. Test and Evaluation of the Zoll Medical Inc., PD2OOO Cardiac Monitor/Pacemaker/Defibrillator System

    National Research Council Canada - National Science Library

    Hade, Edward

    1997-01-01

    The Zoll PD2000 is a portable cardiac monitor, defibrillator and pacemaker that offers synchronized defibrillation, electrocardiogram monitoring, noninvasive temporary pacing and advisory capability...

  16. Clinical application of transvenous temporary cardiac pacemaker in performing extra-cranial carotid angiography and stent implantation

    International Nuclear Information System (INIS)

    Liu Juan; Yao Guoen; Zhou Huadong; Jiang Xiaojiang; Chen Qiao

    2012-01-01

    Objective: To assess the safety and effectiveness of transvenous temporary cardiac pacemaker in preventing hemodynamic instability occurred during the perioperative period of extra-cranial carotid angiography and stent implantation. Methods: Preoperative install of temporary cardiac pacemaker via left femoral vein was carried out in 41 patients who were at high risk for developing hemodynamic instability, which was followed by extra-cranial carotid angiography and stent implantation. The pacing rhythm of the pacemaker was fixed at 60 beats/min. During and after the procedure the patients were under close observation for the signs of discomfort symptoms as well as the changes in blood pressure and heart rate. The working condition of the pacemaker was also monitored. Results: All the installed pacemakers were technically and hemodynamically effective in producing electrical ventricular responses in all 25 patients who had received balloon dilatation of carotid in advance. Transient pacemaker activation appeared in 25 patients. The longest activation time was one day. During pacemaker activation, one patient developed symptomatic hypotension. The longest duration of hypotension lasted for 4 days. No pacemaker-related or procedure-related complications occurred. Conclusion: Hemodynamic instability is a common complication occurred during perioperative period of extra-cranial carotid angiography and stent implantation. As a prophylactic measure, preoperative placement of temporary cardiac pacemaker can promptly and effectively correct the hemodynamic disorders and prevent perioperative complications such as stroke, etc. Therefore, this technique is worth employing in clinical practice, and it is especially useful for patients with high risks. (authors)

  17. Trends in permanent pacemaker implantation in the United States from 1993 to 2009: increasing complexity of patients and procedures.

    Science.gov (United States)

    Greenspon, Arnold J; Patel, Jasmine D; Lau, Edmund; Ochoa, Jorge A; Frisch, Daniel R; Ho, Reginald T; Pavri, Behzad B; Kurtz, Steven M

    2012-10-16

    This study sought to define contemporary trends in permanent pacemaker use by analyzing a large national database. The Medicare National Coverage Determination for permanent pacemaker, which emphasized single-chamber pacing, has not changed significantly since 1985. We sought to define contemporary trends in permanent pacemaker use by analyzing a large national database. We queried the Nationwide Inpatient Sample to identify permanent pacemaker implants between 1993 and 2009 using the International Classification of Diseases-Ninth Revision-Clinical Modification procedure codes for dual-chamber (DDD), single-ventricular (VVI), single-atrial (AAI), or biventricular (BiV) devices. Annual permanent pacemaker implantation rates and patient demographics were analyzed. Between 1993 and 2009, 2.9 million patients received permanent pacemakers in the United States. Overall use increased by 55.6%. By 2009, DDD use increased from 62% to 82% (p pacemaker use fell from 36% to 14% (p = 0.01). Use of DDD devices was higher in urban, nonteaching hospitals (79%) compared with urban teaching hospitals (76%) and rural hospitals (72%). Patients with private insurance (83%) more commonly received DDD devices than Medicaid (79%) or Medicare (75%) recipients (p pacemakers in the United States. Although DDD device use is increasing, whereas single-chamber ventricular pacemaker use is decreasing. Patients are becoming older and have more medical comorbidities. These trends have important health care policy implications. Copyright © 2012 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  18. Is metabolic rate a universal 'pacemaker' for biological processes?

    Science.gov (United States)

    Glazier, Douglas S

    2015-05-01

    A common, long-held belief is that metabolic rate drives the rates of various biological, ecological and evolutionary processes. Although this metabolic pacemaker view (as assumed by the recent, influential 'metabolic theory of ecology') may be true in at least some situations (e.g. those involving moderate temperature effects or physiological processes closely linked to metabolism, such as heartbeat and breathing rate), it suffers from several major limitations, including: (i) it is supported chiefly by indirect, correlational evidence (e.g. similarities between the body-size and temperature scaling of metabolic rate and that of other biological processes, which are not always observed) - direct, mechanistic or experimental support is scarce and much needed; (ii) it is contradicted by abundant evidence showing that various intrinsic and extrinsic factors (e.g. hormonal action and temperature changes) can dissociate the rates of metabolism, growth, development and other biological processes; (iii) there are many examples where metabolic rate appears to respond to, rather than drive the rates of various other biological processes (e.g. ontogenetic growth, food intake and locomotor activity); (iv) there are additional examples where metabolic rate appears to be unrelated to the rate of a biological process (e.g. ageing, circadian rhythms, and molecular evolution); and (v) the theoretical foundation for the metabolic pacemaker view focuses only on the energetic control of biological processes, while ignoring the importance of informational control, as mediated by various genetic, cellular, and neuroendocrine regulatory systems. I argue that a comprehensive understanding of the pace of life must include how biological activities depend on both energy and information and their environmentally sensitive interaction. This conclusion is supported by extensive evidence showing that hormones and other regulatory factors and signalling systems coordinate the processes of

  19. Swimming in Deep Water: Childhood Bipolar Disorder

    Science.gov (United States)

    Senokossoff, Gwyn W.; Stoddard, Kim

    2009-01-01

    The authors focused on one parent's struggles in finding a diagnosis and intervention for a child who had bipolar disorder. The authors explain the process of identification, diagnosis, and intervention of a child who had bipolar disorder. In addition to the personal story, the authors provide information on the disorder and outline strategies…

  20. Bipolar disorder diagnosis: challenges and future directions

    Science.gov (United States)

    Phillips, Mary L; Kupfer, David J

    2018-01-01

    Bipolar disorder refers to a group of affective disorders, which together are characterised by depressive and manic or hypomanic episodes. These disorders include: bipolar disorder type I (depressive and manic episodes: this disorder can be diagnosed on the basis of one manic episode); bipolar disorder type II (depressive and hypomanic episodes); cyclothymic disorder (hypomanic and depressive symptoms that do not meet criteria for depressive episodes); and bipolar disorder not otherwise specified (depressive and hypomanic-like symptoms that do not meet the diagnostic criteria for any of the aforementioned disorders). Bipolar disorder type II is especially difficult to diagnose accurately because of the difficulty in differentiation of this disorder from recurrent unipolar depression (recurrent depressive episodes) in depressed patients. The identification of objective biomarkers that represent pathophysiologic processes that differ between bipolar disorder and unipolar depression can both inform bipolar disorder diagnosis and provide biological targets for the development of new and personalised treatments. Neuroimaging studies could help the identification of biomarkers that differentiate bipolar disorder from unipolar depression, but the problem in detection of a clear boundary between these disorders suggests that they might be better represented as a continuum of affective disorders. Innovative combinations of neuroimaging and pattern recognition approaches can identify individual patterns of neural structure and function that accurately ascertain where a patient might lie on a behavioural scale. Ultimately, an integrative approach, with several biological measurements using different scales, could yield patterns of biomarkers (biosignatures) to help identify biological targets for personalised and new treatments for all affective disorders. PMID:23663952

  1. Transient Stuttering in Catatonic Bipolar Patients

    Directory of Open Access Journals (Sweden)

    Anthony B. Joseph

    1991-01-01

    Full Text Available Two cases of transient stuttering occurring in association with catatonia and bipolar disorder are described. Affective decompensation has been associated with lateralized cerebral dysfunction, and it is hypothesized that in some bipolar catatonic patients a concomitant disorder of the lateralization of language function may lead to a variety of clinical presentations including aphasia, mutism, and stuttering.

  2. Cognitive behavioral therapy for bipolar disorders

    OpenAIRE

    Lotufo Neto, Francisco

    2004-01-01

    Descrição dos objetivos e principais técnicas da terapia comportamental cognitiva usadas para a psicoterapia das pessoas com transtorno bipolar.Objectives and main techniques of cognitive behavior therapy for the treatment of bipolar disorder patients are described.

  3. NO signaling in retinal bipolar cells.

    Science.gov (United States)

    Agurto, A; Vielma, A H; Cadiz, B; Couve, E; Schmachtenberg, O

    2017-08-01

    Nitric oxide (NO) is a neuromodulator involved in physiological and pathological processes in the retina. In the inner retina, a subgroup of amacrine cells have been shown to synthesize NO, but bipolar cells remain controversial as NO sources. This study correlates NO synthesis in dark-adapted retinas, through labeling with the NO marker DAF-FM, with neuronal nitric oxide synthase (nNOS) and inducible NOS expression, and presence of the NO receptor soluble guanylate cyclase in bipolar cells. NO containing bipolar cells were morphologically identified by dialysis of DAF fluorescent cells with intracellular dyes, or by DAF labeling followed by immunohistochemistry for nNOS and other cellular markers. DAF fluorescence was observed in all types of bipolar cells that could be identified, but the most intense DAF fluorescence was observed in bipolar cells with severed processes, supporting pathological NO signaling. Among nNOS expressing bipolar cells, type 9 was confirmed unequivocally, while types 2, 3a, 3b, 4, 5, 7, 8 and the rod bipolar cell were devoid of this enzyme. These results establish specific bipolar cell types as NO sources in the inner retina, and support the involvement of NO signaling in physiological and pathological processes in the inner retina. Copyright © 2017 Elsevier Ltd. All rights reserved.

  4. Bipolar Disorder and Cognitive Dysfunction: A Complex Link.

    Science.gov (United States)

    Cipriani, Gabriele; Danti, Sabrina; Carlesi, Cecilia; Cammisuli, Davide Maria; Di Fiorino, Mario

    2017-10-01

    The aim of this article was to describe the current evidence regarding phenomenon of cognitive functioning and dementia in bipolar disorder (BD). Cochrane Library and PubMed searches were conducted for relevant articles, chapters, and books published before 2016. Search terms used included "bipolar disorder," "cognitive dysfunction," and "dementia." At the end of the selection process, 159 studies were included in our qualitative synthesis. As result, cognitive impairments in BD have been previously considered as infrequent and limited to the affective episodes. Nowadays, there is evidence of stable and lasting cognitive dysfunctions in all phases of BD, including remission phase, particularly in the following domains: attention, memory, and executive functions. The cause of cognitive impairment in BD raises the question if it subtends a neurodevelopmental or a neurodegenerative process. Impaired cognitive functioning associated with BD may contribute significantly to functional disability, in addition to the distorted affective component usually emphasized.

  5. Placement Of Cardiac PacemaKEr Trial (POCKET – rationale and design: a randomized controlled trial

    Directory of Open Access Journals (Sweden)

    Peter Magnusson

    2017-04-01

    Full Text Available Background: A pacemaker system consists of one or two leads connected to a device that is implanted into a pocket formed just below the collarbone. This pocket is typically subcutaneous, that is, located just above the pectoral fascia. Even though the size of pacemakers has decreased markedly, complications due to superficial implants do occur. An alternative technique would be intramuscular placement of the pacemaker device, but there are no randomized controlled trials (RCTs to support this approach, which is the rationale for the Placement Of Cardiac PacemaKEr Trial (POCKET. The aim is to study if intramuscular is superior to subcutaneous placement of a pacemaker pocket. Methods: In October 2016, we started to enroll 200 consecutive patients with an indication for bradycardia pacemaker implantation. Patients are randomized to random block sizes, stratified by age group (cut-off: 65 years and sex, and then randomized to either subcutaneous or intramuscular implant. A concealed allocation procedure is employed, using sequentially numbered, sealed envelopes. Pocket site is blinded to the patient and in all subsequent care. The primary endpoint is patient overall satisfaction with the pocket location at 24 months as measured using a visual analog scale (VAS 0-10. Secondary endpoints are: complications, patient-reported satisfaction at 1, 12, and 24 months (overall satisfaction, pain, discomfort, degree of unsightly appearance, movement problems, and sleep problems due to device. Conclusions: POCKET is a prospective interventional RCT designed to evaluate if intramuscular is superior to subcutaneous placement of a bradycardia pacemaker during a two-year follow-up.

  6. Pacemakers in patients with familial dysautonomia--a review of experience with 20 patients.

    Science.gov (United States)

    Gold-von Simson, Gabrielle; Rutkowski, Monika; Berlin, Dena; Axelrod, Felicia B

    2005-02-01

    Familial dysautonomia (FD) is a genetic disease associated with a high incidence of sudden death. If fatal bradyarrhythmia is an etiological factor then the incidence of sudden death should decrease after pacemaker placement. Retrospective review of 596 registered FD patients revealed that 22 FD patients (3.7%) had pacemakers placed between December 1984 and June 2003. Clinical and electrocardiographic indications for placement and demographic data were assessed for 20 of the 22 patients (10 males, 10 females, ages 4 to 48 years). Two patients were excluded because of insufficient data. Prior to pacemaker placement, presenting symptoms were syncope and cardiac arrest, 16/20 (80%) and 6/20 (30 %), respectively. Asystole was the most frequent electrocardiographic finding and was documented in 17/20 patients (85 %). Other electrocardiographic abnormalities included bradycardia, AV block, prolonged QTc and prolonged JTc. The average duration of pacemaker utilization was 5.7 years (range 5 months to 14.5 years). Complications included infection (1 patient) and wire migration (2 patients). In the one patient with infection, the pacemaker was permanently removed. This patient then experienced multiple syncopal episodes and death. There were 7 other deaths. Three deaths occurred suddenly without preceding events, and 4 patients had non-cardiac causes of death. None of these 7 deceased patients had recurrence of syncope after pacemaker placement. In the 12 surviving patients, 6 had recurrence of syncope but none had cardiac arrest. Pacemaker placement may protect FD patients from fatal bradyarrhythmia and may decrease the incidence of syncope. However, data are limited and prospective analysis is needed.

  7. Placement Of Cardiac PacemaKEr Trial (POCKET – rationale and design: a randomized controlled trial

    Directory of Open Access Journals (Sweden)

    Peter Magnusson

    2017-04-01

    Full Text Available BackgroundA pacemaker system consists of one or two leads connected to a device that is implanted into a pocket formed just below the collarbone. This pocket is typically subcutaneous, that is, located just above the pectoral fascia. Even though the size of pacemakers has decreased markedly, complications due to superficial implants do occur. An alternative technique would be intramuscular placement of the pacemaker device, but there are no randomized controlled trials (RCTs to support this approach, which is the rationale for the Placement Of Cardiac PacemaKEr Trial (POCKET. The aim is to study if intramuscular is superior to subcutaneous placement of a pacemaker pocket.MethodsIn October 2016, we started to enroll 200 consecutive patients with an indication for bradycardia pacemaker implantation. Patients are randomized to random block sizes, stratified by age group (cut-off: 65 years and sex, and then randomized to either subcutaneous or intramuscular implant. A concealed allocation procedure is employed, using sequentially numbered, sealed envelopes. Pocket site is blinded to the patient and in all subsequent care. The primary endpoint is patient overall satisfaction with the pocket location at 24 months as measured using a visual analog scale (VAS 0-10. Secondary endpoints are: complications, patient-reported satisfaction at 1, 12, and 24 months (overall satisfaction, pain, discomfort, degree of unsightly appearance, movement problems, and sleep problems due to device.ConclusionsPOCKET is a prospective interventional RCT designed to evaluate if intramuscular is superior to subcutaneous placement of a bradycardia pacemaker during a two-year follow-up.

  8. Long-Term Mortality Effect of Early Pacemaker Implantation After Surgical Aortic Valve Replacement.

    Science.gov (United States)

    Greason, Kevin L; Lahr, Brian D; Stulak, John M; Cha, Yong-Mei; Rea, Robert F; Schaff, Hartzell V; Dearani, Joseph A

    2017-10-01

    The need for pacemaker implantation is a well-described complication of aortic valve replacement. Not so well described is the effect such an event has on long-term outcome. This study reviewed a 21-year experience at the Mayo Clinic (Rochester, Minnesota) with aortic valve replacement to understand the influence of early postoperative pacemaker implantation on long-term mortality rates more clearly. This study retrospectively reviewed the records of 5,842 patients without previous pacemaker implantation who underwent surgical aortic valve replacement from January 1993 through June 2014. The median age of these patients was 73 years (range, 65 to 79 years), the median ejection fraction was 62% (range, 53% to 68%), 3,853 patients were male (66%), and coronary artery bypass graft operation was performed in 2,553 (44%) of the patients studied. Early pacemaker implantation occurred in 146 patients (2.5%) within 30 days of surgical aortic valve replacement. The median follow-up of patients was 11.1 years (range, 5.8 to 16.5 years), and all-cause mortality rates were 2.4% at 30 days, 6.4% at 1 year, 23.1% at 5 years, 48.3% at 10 years, and 67.9% at 15 years postoperatively. Early pacemaker implantation was associated with an increased risk of death after multivariable adjustment for baseline patients' characteristics (hazard ratio, 1.49; 95% confidence interval, 1.20, 1.84; p pacemaker implantation as a complication of surgical aortic valve replacement is associated with an increased risk of long-term death. Valve replacement-related pacemaker implantation rates should be important considerations with respect to new valve replacement paradigms, especially in younger and lower-risk patients. Copyright © 2017 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  9. Case study thoracic radiotherapy in an elderly patient with pacemaker: The issue of pacing leads

    Energy Technology Data Exchange (ETDEWEB)

    Kirova, Youlia M., E-mail: youlia.kirova@curie.net [Department of Radiation Oncology, Institut Curie, Paris (France); Menard, Jean; Chargari, Cyrus; Mazal, Alejandro [Department of Radiation Oncology, Institut Curie, Paris (France); Kirov, Krassen [Department of Anesthesiology and Reanimation, Institut Curie, Paris (France)

    2012-07-01

    To assess clinical outcome of patients with pacemaker treated with thoracic radiation therapy for T8-T9 paravertebral chloroma. A 92-year-old male patient with chloroma presenting as paravertebral painful and compressive (T8-T9) mass was referred for radiotherapy in the Department of Radiation Oncology, Institut Curie. The patient presented with cardiac dysfunction and a permanent pacemaker that had been implanted prior. The decision of Multidisciplinary Meeting was to deliver 30 Gy in 10 fractions for reducing the symptoms and controlling the tumor growth. The patient received a total dose of 30 Gy in 10 fractions using 4-field conformal radiotherapy with 20-MV photons. The dose to pacemaker was 0.1 Gy but a part of the pacing leads was in the irradiation fields. The patient was treated the first time in the presence of his radiation oncologist and an intensive care unit doctor. Moreover, the function of his pacemaker was monitored during the entire radiotherapy course. No change in pacemaker function was observed during any of the radiotherapy fractions. The radiotherapy was very well tolerated without any side effects. The function of the pacemaker was checked before and after the radiotherapy treatment by the cardiologist and no pacemaker dysfunction was observed. Although updated guidelines are needed with acceptable dose criteria for implantable cardiac devices, it is possible to treat patients with these devices and parts encroaching on the radiation field. This case report shows we were able to safely treat our patient through a multidisciplinary approach, monitoring the patient during each step of the treatment.

  10. Case study thoracic radiotherapy in an elderly patient with pacemaker: The issue of pacing leads

    International Nuclear Information System (INIS)

    Kirova, Youlia M.; Menard, Jean; Chargari, Cyrus; Mazal, Alejandro; Kirov, Krassen

    2012-01-01

    To assess clinical outcome of patients with pacemaker treated with thoracic radiation therapy for T8-T9 paravertebral chloroma. A 92-year-old male patient with chloroma presenting as paravertebral painful and compressive (T8-T9) mass was referred for radiotherapy in the Department of Radiation Oncology, Institut Curie. The patient presented with cardiac dysfunction and a permanent pacemaker that had been implanted prior. The decision of Multidisciplinary Meeting was to deliver 30 Gy in 10 fractions for reducing the symptoms and controlling the tumor growth. The patient received a total dose of 30 Gy in 10 fractions using 4-field conformal radiotherapy with 20-MV photons. The dose to pacemaker was 0.1 Gy but a part of the pacing leads was in the irradiation fields. The patient was treated the first time in the presence of his radiation oncologist and an intensive care unit doctor. Moreover, the function of his pacemaker was monitored during the entire radiotherapy course. No change in pacemaker function was observed during any of the radiotherapy fractions. The radiotherapy was very well tolerated without any side effects. The function of the pacemaker was checked before and after the radiotherapy treatment by the cardiologist and no pacemaker dysfunction was observed. Although updated guidelines are needed with acceptable dose criteria for implantable cardiac devices, it is possible to treat patients with these devices and parts encroaching on the radiation field. This case report shows we were able to safely treat our patient through a multidisciplinary approach, monitoring the patient during each step of the treatment.

  11. Thyroid Functions and Bipolar Affective Disorder

    Directory of Open Access Journals (Sweden)

    Subho Chakrabarti

    2011-01-01

    Full Text Available Accumulating evidence suggests that hypothalamo-pituitary-thyroid (HPT axis dysfunction is relevant to the pathophysiology and clinical course of bipolar affective disorder. Hypothyroidism, either overt or more commonly subclinical, appears to the commonest abnormality found in bipolar disorder. The prevalence of thyroid dysfunction is also likely to be greater among patients with rapid cycling and other refractory forms of the disorder. Lithium-treatment has potent antithyroid effects and can induce hypothyroidism or exacerbate a preexisting hypothyroid state. Even minor perturbations of the HPT axis may affect the outcome of bipolar disorder, necessitating careful monitoring of thyroid functions of patients on treatment. Supplementation with high dose thyroxine can be considered in some patients with treatment-refractory bipolar disorder. Neurotransmitter, neuroimaging, and genetic studies have begun to provide clues, which could lead to an improved understanding of the thyroid-bipolar disorder connection, and more optimal ways of managing this potentially disabling condition.

  12. Diagnostic stability in pediatric bipolar disorder

    DEFF Research Database (Denmark)

    Vedel Kessing, Lars; Vradi, Eleni; Andersen, Per Kragh

    2015-01-01

    BACKGROUND: The diagnostic stability of pediatric bipolar disorder has not been investigated previously. The aim was to investigate the diagnostic stability of the ICD-10 diagnosis of pediatric mania/bipolar disorder.METHODS: All patients below 19 years of age who got a diagnosis of mania/bipolar...... disorder at least once in a period from 1994 to 2012 at psychiatric inpatient or outpatient contact in Denmark were identified in a nationwide register.RESULTS: Totally, 354 children and adolescents got a diagnosis of mania/bipolar disorder at least once; a minority, 144 patients (40.7%) got the diagnosis...... at the first contact whereas the remaining patients (210; 59.3%) got the diagnosis at later contacts before age 19. For the latter patients, the median time elapsed from first treatment contact with the psychiatric service system to the first diagnosis with a manic episode/bipolar disorder was nearly 1 year...

  13. 2017 Bipolar Plate Workshop Summary Report

    Energy Technology Data Exchange (ETDEWEB)

    Kopasz, John P. [Argonne National Lab. (ANL), Argonne, IL (United States); Benjamin, Thomas G. [Argonne National Lab. (ANL), Argonne, IL (United States); Schenck, Deanna [Argonne National Lab. (ANL), Argonne, IL (United States)

    2017-08-17

    The Bipolar Plate (BP) Workshop was held at USCAR1 in Southfield, Michigan on February 14, 2017 and included 63 participants from industry, government agencies, universities, and national laboratories with expertise in the relevant fields. The objective of the workshop was to identify research and development (R&D) needs, in particular early-stage R&D, for bipolar plates for polymer electrolyte membrane (PEM) fuel cells for transportation applications. The focus of the workshop was on materials, manufacturing, and design aspects of bipolar plates with the goal of meeting DOE’s 2020 bipolar plate targets. Of special interest was the cost target of ≤$3/kW for the bipolar plate.

  14. Association between history of psychosis and cardiovascular disease in bipolar disorder.

    Science.gov (United States)

    Prieto, Miguel L; McElroy, Susan L; Hayes, Sharonne N; Sutor, Bruce; Kung, Simon; Bobo, William V; Fuentes, Manuel E; Cuellar-Barboza, Alfredo B; Crow, Scott; Ösby, Urban; Chauhan, Mohit; Westman, Jeanette; Geske, Jennifer R; Colby, Colin L; Ryu, Euijung; Biernacka, Joanna M; Frye, Mark A

    2015-08-01

    To determine whether clinical features of bipolar disorder, such as history of psychosis, and cardiovascular disease (CVD) risk factors contribute to a higher risk of CVD among patients with bipolar disorder. This cross-sectional study included a sample of 988 patients with bipolar I or bipolar II disorder or schizoaffective bipolar type confirmed by the Structured Clinical Interview for DSM-IV-TR disorders (SCID). Medical comorbidity burden was quantified utilizing the Cumulative Illness Severity Rating Scale (CIRS). This 13-item organ-based scale includes cardiac disease severity quantification. Confirmed by medical record review, patients who scored 1 (current mild or past significant problem) or higher in the cardiac item were compared by logistic regression to patients who scored 0 (no impairment), adjusting for CVD risk factors that were selected using a backwards stepwise approach or were obtained from the literature. In a multivariate model, age [odds ratio (OR) = 3.03, 95% confidence interval (CI): 1.66-5.54, p bipolar disorder may reflect higher illness severity with associated cardiac comorbidity. Further studies are encouraged to clarify the effect of the disease burden (i.e., depression), lifestyle, and treatment interventions (i.e., atypical antipsychotics) on this risk association. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  15. Homocysteine as a potential biomarker in bipolar disorders: a critical review and suggestions for improved studies.

    Science.gov (United States)

    Ghanizadeh, Ahmad; Singh, Ajeet B; Berk, Michael; Torabi-Nami, Mohammad

    2015-07-01

    Homocysteine levels have been associated with major depression, but associations with bipolar disorder remain less clear. Some data suggest homocysteine levels have potential as a biomarker of treatment response; however the literature is mixed. Oxidized forms of homocysteine can be potentially neurotoxic leading to glutamate toxicity, apoptotic transformation and neurodegenerative processes. High homocysteine may be a risk biomarker for bipolar disorders, but the empirical base remains too weak for firm conclusions. This review discusses the current literature for homocysteine levels as a biomarker. It is premature to foreclose the utility of homocysteine levels as a biomarker for bipolar disorder due the methodological inadequacies in the existing literature. These methodological design issues include lack of control for the confounding variables of concurrent medication, phase of bipolar disorder, gender, age, nutritional status, thyroid, liver and renal function, smoking or lean body mass. Well-powered association studies with confounder control could help shed more light on the important clinical question of homocysteine's utility as a biomarker in bipolar disorder. Future experiments are needed to examine the outcome of interventions modulating homocysteine for treating bipolar disorder. Only prospective randomized control trials will provide definitive evidence of the utility of homocysteine as a biomarker or therapeutic target.

  16. Polarity of the first episode and time to diagnosis of bipolar I disorder.

    Science.gov (United States)

    Cha, Boseok; Kim, Jeong Hyun; Ha, Tae Hyon; Chang, Jae Seung; Ha, Kyooseob

    2009-06-01

    The current study explored the relationship between the polarity of the first episode and the timing of eventual diagnosis of bipolar I disorder, and associated clinical implications. Twelve years of clinical data from the medical records of 258 inpatients meeting DSM-III-R or DSM-IV criteria for bipolar I disorder were analyzed. Subjects were divided into two groups according to the polarity of the first episode: those with depressive polarity (FE-D), and those with manic polarity (FE-M). Comparisons were made between the two groups on variables associated with the timing of diagnosis and related outcomes. In population with bipolar I disorder, a significant longer time lapse from the first major mood episode to the confirmed diagnosis was associated with the FE-D group compared to the FE-M group [5.6 (+/-6.1) vs. 2.5 (+/-5.5) years, pschizophrenia and major depressive disorder while FE-M subjects tended to have prior diagnoses of bipolar disorder and schizophrenia. A significantly higher rate of suicide attempts was associated with the FE-D group compared to the FE-M group (12.7 vs. 1.7%, pdepressive polarity is likely to be followed by a considerable delay until an eventual confirmed diagnosis of bipolar I disorder. Given that first-episode depressive patients are particularly vulnerable to unfavorable clinical outcomes such as suicide attempts, a more systematic approach is needed to differentiate bipolar disorder among depressed patients in their early stages.

  17. The efficacy of cognitive-behavioral therapy in bipolar disorder: a quantitative meta-analysis.

    Science.gov (United States)

    Szentagotai, Aurora; David, Daniel

    2010-01-01

    The goal of the current study was to conduct a quantitative meta-analysis investigating the role of cognitive-behavioral therapy (CBT) as adjunctive treatment to medication for patients diagnosed with bipolar disorder. Studies included in the sample were identified through a computer search of articles in English in the MEDLINE database from January 1980 to March 2008. Key terms entered were cognitive and bipolar disorder, cognitive therapy and bipolar disorder, cognitive behavioral therapy and bipolar disorder, psychotherapy and bipolar disorder, and psychosocial and bipolar disorder. Inclusion criteria were (1) randomized clinical trial investigating the role of adjunctive CBT in patients diagnosed with bipolar disorder, (2) clearly defined CBT intervention, (3) the inclusion of a control group, and (4) sufficient data reported to allow calculation of effect sizes. Twelve randomized clinical trials were selected for analysis on the basis of these criteria. Effect sizes (Cohen d) were calculated according to published procedures. We found a low to medium overall effect size of CBT at posttreatment (d = -0.42, P cognitive-behavioral etiopathogenetic mechanisms (posttreatment d = -0.49, P case of relapse and/or recurrence (posttreatment d = -0.28). These effects on outcome categories were more evident at posttreatment compared to follow-up. Cognitive-behavioral therapy can be used as an adjunctive treatment to medication for patients with bipolar disorder, but new CBT strategies are needed to increase and enrich the impact of CBT at posttreatment and to maintain its benefits during follow-up. ©Copyright 2010 Physicians Postgraduate Press, Inc.

  18. Can bipolar disorder be viewed as a multi-system inflammatory disease?

    Science.gov (United States)

    Leboyer, Marion; Soreca, Isabella; Scott, Jan; Frye, Mark; Henry, Chantal; Tamouza, Ryad; Kupfer, David J.

    2012-01-01

    Background Patients with bipolar disorder are known to be at high risk of premature death. Comorbid cardio-vascular diseases are a leading cause of excess mortality, well above the risk associated with suicide. In this review, we explore comorbid medical disorders, highlighting evidence that bipolar disorder can be effectively conceptualized as a multi-systemic inflammatory disease. Methods We conducted a systematic PubMed search of all English-language articles recently published with bipolar disorder cross-referenced with the following terms: mortality and morbidity, cardio-vascular, diabetes, obesity, metabolic syndrome, inflammation, auto-antibody, retro-virus, stress, sleep and circadian rhythm. Results Evidence gathered so far suggests that the multi-system involvement is present from the early stages, and therefore requires proactive screening and diagnostic procedures, as well as comprehensive treatment to reduce progression and premature mortality. Exploring the biological pathways that could account for the observed link show that dysregulated inflammatory background could be a common factor underlying cardio-vascular and bipolar disorders. Viewing bipolar disorder as a multi-system disorder should help us to re-conceptualize disorders of the mind as “disorders of the brain and the body”. Limitations The current literature substantially lacks longitudinal and mechanistic studies, as well as comparison studies to explore the magnitude of the medical burden in bipolar disorder compared to major mood disorders as well as psychotic disorders. It is also necessary to look for subgroups of bipolar disorder based on their rates of comorbid disorders. Conclusions Comorbid medical illnesses in bipolar disorder might be viewed not only as the consequence of health behaviors and of psychotropic medications, but rather as an early manifestation of a multi-systemic disorder. Medical monitoring is thus a critical component of case assessment. Exploring common

  19. Treating nonspecific anxiety and anxiety disorders in patients with bipolar disorder: a review.

    Science.gov (United States)

    Rakofsky, Jeffrey J; Dunlop, Boadie W

    2011-01-01

    are recommended for treatment of anxiety disorders present in patients with bipolar disorder not currently experiencing an acute mood episode. © Copyright 2011 Physicians Postgraduate Press, Inc.

  20. Randomized, controlled trial of Interpersonal and Social Rhythm Therapy for young people with bipolar disorder.

    Science.gov (United States)

    Inder, Maree L; Crowe, Marie T; Luty, Suzanne E; Carter, Janet D; Moor, Stephanie; Frampton, Christopher M; Joyce, Peter R

    2015-03-01

    This randomized, controlled clinical trial compared the effect of interpersonal and social rhythm therapy (IPSRT) to that of specialist supportive care (SSC) on depressive outcomes (primary), social functioning, and mania outcomes over 26-78 weeks in young people with bipolar disorder receiving psychopharmacological treatment. Subjects were aged 15-36 years, recruited from a range of sources, and the patient groups included bipolar I disorder, bipolar II disorder, and bipolar disorder not otherwise specified. Exclusion criteria were minimal. Outcome measures were the Longitudinal Interval Follow-up Evaluation and the Social Adjustment Scale. Paired-sample t-tests were used to determine the significance of change from baseline to outcome period. Analyses of covariance were used to determine the impact of therapy, impact of lifetime and current comorbidity, interaction between comorbidity and therapy, and impact of age at study entry on depression. A group of 100 participants were randomized to IPSRT (n = 49) or SSC (n = 51). The majority had bipolar I disorder (78%) and were female (76%), with high levels of comorbidity. After treatment, both groups had improved depressive symptoms, social functioning, and manic symptoms. Contrary to our hypothesis, there was no significant difference between therapies. There was no impact of lifetime or current Axis I comorbidity or age at study entry. There was a relative impact of SSC for patients with current substance use disorder. IPSRT and SSC used as an adjunct to pharmacotherapy appear to be effective in reducing depressive and manic symptoms and improving social functioning in adolescents and young adults with bipolar disorder and high rates of comorbidity. Identifying effective treatments that particularly address depressive symptoms is important in reducing the burden of bipolar disorder. © 2014 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  1. Staging in bipolar disorder: from theoretical framework to clinical utility.

    Science.gov (United States)

    Berk, Michael; Post, Robert; Ratheesh, Aswin; Gliddon, Emma; Singh, Ajeet; Vieta, Eduard; Carvalho, Andre F; Ashton, Melanie M; Berk, Lesley; Cotton, Susan M; McGorry, Patrick D; Fernandes, Brisa S; Yatham, Lakshmi N; Dodd, Seetal

    2017-10-01

    ) explore the current level of evidence supporting the descriptive staging of the syndromal pattern of bipolar disorder; b) describe preliminary attempts at validation; c) make recommendations for the direction of further studies; and d) provide a distillation of the potential clinical implications of staging in bipolar disorder within a broader transdiagnostic framework. © 2017 World Psychiatric Association.

  2. DeepBipolar: Identifying genomic mutations for bipolar disorder via deep learning.

    Science.gov (United States)

    Laksshman, Sundaram; Bhat, Rajendra Rana; Viswanath, Vivek; Li, Xiaolin

    2017-09-01

    Bipolar disorder, also known as manic depression, is a brain disorder that affects the brain structure of a patient. It results in extreme mood swings, severe states of depression, and overexcitement simultaneously. It is estimated that roughly 3% of the population of the United States (about 5.3 million adults) suffers from bipolar disorder. Recent research efforts like the Twin studies have demonstrated a high heritability factor for the disorder, making genomics a viable alternative for detecting and treating bipolar disorder, in addition to the conventional lengthy and costly postsymptom clinical diagnosis. Motivated by this study, leveraging several emerging deep learning algorithms, we design an end-to-end deep learning architecture (called DeepBipolar) to predict bipolar disorder based on limited genomic data. DeepBipolar adopts the Deep Convolutional Neural Network (DCNN) architecture that automatically extracts features from genotype information to predict the bipolar phenotype. We participated in the Critical Assessment of Genome Interpretation (CAGI) bipolar disorder challenge and DeepBipolar was considered the most successful by the independent assessor. In this work, we thoroughly evaluate the performance of DeepBipolar and analyze the type of signals we believe could have affected the classifier in distinguishing the case samples from the control set. © 2017 Wiley Periodicals, Inc.

  3. Comparison of depressive episodes in bipolar disorder and in major depressive disorder within bipolar disorder pedigrees.

    Science.gov (United States)

    Mitchell, Philip B; Frankland, Andrew; Hadzi-Pavlovic, Dusan; Roberts, Gloria; Corry, Justine; Wright, Adam; Loo, Colleen K; Breakspear, Michael

    2011-10-01

    Although genetic epidemiological studies have confirmed increased rates of major depressive disorder among the relatives of people with bipolar affective disorder, no report has compared the clinical characteristics of depression between these two groups. To compare clinical features of depressive episodes across participants with major depressive disorder and bipolar disorder from within bipolar disorder pedigrees, and assess the utility of a recently proposed probabilistic approach to distinguishing bipolar from unipolar depression. A secondary aim was to identify subgroups within the relatives with major depression potentially indicative of 'genetic' and 'sporadic' subgroups. Patients with bipolar disorder types 1 and 2 (n = 246) and patients with major depressive disorder from bipolar pedigrees (n = 120) were assessed using the Diagnostic Interview for Genetic Studies. Logistic regression was used to identify distinguishing clinical features and assess the utility of the probabilistic approach. Hierarchical cluster analysis was used to identify subgroups within the major depressive disorder sample. Bipolar depression was characterised by significantly higher rates of psychomotor retardation, difficulty thinking, early morning awakening, morning worsening and psychotic features. Depending on the threshold employed, the probabilistic approach yielded a positive predictive value ranging from 74% to 82%. Two clusters within the major depressive disorder sample were found, one of which demonstrated features characteristic of bipolar depression, suggesting a possible 'genetic' subgroup. A number of previously identified clinical differences between unipolar and bipolar depression were confirmed among participants from within bipolar disorder pedigrees. Preliminary validation of the probabilistic approach in differentiating between unipolar and bipolar depression is consistent with dimensional distinctions between the two disorders and offers clinical utility in

  4. A YinYang bipolar fuzzy cognitive TOPSIS method to bipolar disorder diagnosis.

    Science.gov (United States)

    Han, Ying; Lu, Zhenyu; Du, Zhenguang; Luo, Qi; Chen, Sheng

    2018-05-01

    Bipolar disorder is often mis-diagnosed as unipolar depression in the clinical diagnosis. The main reason is that, different from other diseases, bipolarity is the norm rather than exception in bipolar disorder diagnosis. YinYang bipolar fuzzy set captures bipolarity and has been successfully used to construct a unified inference mathematical modeling method to bipolar disorder clinical diagnosis. Nevertheless, symptoms and their interrelationships are not considered in the existing method, circumventing its ability to describe complexity of bipolar disorder. Thus, in this paper, a YinYang bipolar fuzzy multi-criteria group decision making method to bipolar disorder clinical diagnosis is developed. Comparing with the existing method, the new one is more comprehensive. The merits of the new method are listed as follows: First of all, multi-criteria group decision making method is introduced into bipolar disorder diagnosis for considering different symptoms and multiple doctors' opinions. Secondly, the discreet diagnosis principle is adopted by the revised TOPSIS method. Last but not the least, YinYang bipolar fuzzy cognitive map is provided for the understanding of interrelations among symptoms. The illustrated case demonstrates the feasibility, validity, and necessity of the theoretical results obtained. Moreover, the comparison analysis demonstrates that the diagnosis result is more accurate, when interrelations about symptoms are considered in the proposed method. In a conclusion, the main contribution of this paper is to provide a comprehensive mathematical approach to improve the accuracy of bipolar disorder clinical diagnosis, in which both bipolarity and complexity are considered. Copyright © 2018 Elsevier B.V. All rights reserved.

  5. Interference of neodymium magnets with cardiac pacemakers and implantable cardioverter-defibrillators: an in vitro study.

    Science.gov (United States)

    Ryf, Salome; Wolber, Thomas; Duru, Firat; Luechinger, Roger

    2008-01-01

    Permanent magnets may interfere with the function of cardiac pacemakers and implantable cardioverter-defibrillators (ICDs). Neodymium-iron-boron (NdFeB) magnets have become widely available in recent years and are incorporated in various articles of daily life. We conducted an in-vitro study to evaluate the ability of NdFeB magnets for home and office use to cause interference with cardiac pacemakers and ICDs. The magnetic fields of ten NdFeB magnets of different size and shape were measured at increasing distances beginning from the surface until a field-strength (B-field) value of 0.5 mT was reached. Furthermore, for each magnet the distance was determined at which a sample pacemaker switched from magnet mode to normal mode. Depending on the size and remanence of individual magnets, a B-field value of 0.5 mT was found at distances ranging from 1.5 cm to 30 cm and a value of 1 mT at distances from 1 cm to 22 cm. The pacemaker behavior was influenced at distances from 1 cm to 24 cm. NdFeB magnets for home and office use may cause interference with cardiac pacemakers and ICDs at distances up to 24 centimeters. Patient education and product declarations should include information about the risk associated with these magnets.

  6. Pre-ejection period by radial artery tonometry supplements echo doppler findings during biventricular pacemaker optimization

    Directory of Open Access Journals (Sweden)

    Qamruddin Salima

    2011-07-01

    Full Text Available Abstract Background Biventricular (Biv pacemaker echo optimization has been shown to improve cardiac output however is not routinely used due to its complexity. We investigated the role of a simple method involving computerized pre-ejection time (PEP assessment by radial artery tonometry in guiding Biv pacemaker optimization. Methods Blinded echo and radial artery tonometry were performed simultaneously in 37 patients, age 69.1 ± 12.8 years, left ventricular (LV ejection fraction (EF 33 ± 10%, during Biv pacemaker optimization. Effect of optimization on echo derived velocity time integral (VTI, ejection time (ET, myocardial performance index (MPI, radial artery tonometry derived PEP and echo-radial artery tonometry derived PEP/VTI and PEP/ET indices was evaluated. Results Significant improvement post optimization was achieved in LV ET (286.9 ± 37.3 to 299 ± 34.6 ms, p Conclusion An acute shortening of PEP by radial artery tonometry occurs post Biv pacemaker optimization and correlates with improvement in hemodynamics by echo Doppler and may provide a cost-efficient approach to assist with Biv pacemaker echo optimization.

  7. Early Performance and Safety of the Micra Transcatheter Pacemaker in Pigs.

    Science.gov (United States)

    Bonner, Matthew; Eggen, Michael; Haddad, Tarek; Sheldon, Todd; Williams, Eric

    2015-11-01

    The Micra® Transcatheter Pacing System (TPS; Medtronic Inc., Minneapolis, MN, USA) is a miniaturized single-chamber pacemaker system that is delivered via catheter through the femoral vein. In this study, the electrical performance was compared between the TPS and a traditional leaded pacemaker. In addition, the safety profile of the two systems was compared by thorough monitoring for a number of adverse events. The TPS was implanted in the right ventricular apex of 10 Yucatan mini pigs and a Medtronic single-lead pacemaker (SLP) was implanted in the right ventricular apex of another 10 pigs and connected to a traditional pacemaker. The electrical performance of all devices was monitored for 12 weeks. The safety profile of each system was characterized using x-ray, computed tomography, ultrasound, blood work, and necropsy to monitor for a variety of adverse events. At implant the mean pacing thresholds were 0.58 ± 0.17 V @0.24 ms and 0.75 ± 0.29 V @0.21 ms for the TPS and the SLP respectively. After 12 weeks, mean thresholds were 0.94 ± 0.46 V and 1.85 ± 0.75 V (P pacemaker system. © 2015 Medtronic PLC. Pacing and Clinical Electrophysiology published by Wiley Periodicals, Inc.

  8. Characteristics and Prognosis of Pacemaker-Identified New-Onset Atrial Fibrillation in Japanese People.

    Science.gov (United States)

    Ogino, Yutaka; Ishikawa, Toshiyuki; Ishigami, Tomoaki; Matsumoto, Katsumi; Hosoda, Junya; Iguchi, Kouhei; Matsushita, Hirooki; Taguchi, Yuka; Horiguchi, Yoriko; Kimura, Kazuo

    2017-05-25

    The characteristics and prognosis of implanted pacemaker-identified new-onset atrial fibrillation (AF) in Japanese people has not been well evaluated.Methods and Results:A total of 395 consecutive patients with newly implanted pacemakers were retrospectively analyzed between January 2010 and December 2015 at Yokohama City University Hospital. Patients with a prior history of AF, VVI mode pacemaker, congenital heart disease, severe valvular heart disease, and cardiovascular surgery before pacemaker implantation were excluded. Among the remaining patients, 44 (21.3%) developed new AF during follow-up (mean follow-up, 1,115±651 days; range, 9-2,176 days). Patients with new-onset AF had a significantly higher CHADS 2 score (2.09±1.27 vs. 1.31±1.08, Ppacemaker-implanted patients with high CHADS 2 and CHA 2 DS 2 -VASc scores developed new-onset AF during a mean follow-up of 3.1 years; and pacemaker-identified AF was associated with an increased risk of worsening heart failure.

  9. Surgical outcome of Fontan conversion and arrhythmia surgery: Need a pacemaker?

    Science.gov (United States)

    Terada, Takafumi; Sakurai, Hajime; Nonaka, Toshimichi; Sakurai, Takahisa; Sugiura, Junya; Taneichi, Tetsuyoshi; Ohtsuka, Ryohei

    2014-07-01

    Atrial tachyarrhythmias are frequent complications in the late period after the Fontan procedure, and important risk factors for a poor prognosis. The impact of Fontan conversion and arrhythmia surgery in failed Fontan patients has been described in many reports. We evaluated our experience with Fontan conversion procedures, concomitant arrhythmia surgery, and pacemaker implantation. We reviewed the hospital records of 25 consecutive patients who underwent a Fontan conversion procedure from January 2004 to March 2012. Twenty-four patients had arrhythmia surgery using cryoablation and radiofrequency ablation at the time of conversion. A bilateral atrial maze procedure was performed in 6 patients, right-side maze in 15, and isthmus block in 3. Three patients with a diagnosis of corrected transposition of the great arteries underwent simultaneous pacemaker implantation electively. There was no early death and one late death during a mean follow-up period of 21.2 months. Three tachyarrhythmia recurrences developed, and there were 4 occurrences of sinus bradycardia. Five of these patients required postoperative pacemaker implantation. The mid-term results of Fontan conversion and arrhythmia surgery in our institute were satisfactory. The occurrence of unexpected postoperative pacemaker requirement was high in the patients who underwent a right atrial or bilateral atrial maze procedure. Pacemaker or lead implantation is recommended for patients planned to undergo a right-side or full maze procedure. © The Author(s) 2013 Reprints and permissions: sagepub.co.uk/journalsPermissions.nav.

  10. Pacemaker System Malfunction Resulting from External Electrical Cardioversion: A Case Report

    Directory of Open Access Journals (Sweden)

    Taku Nishida, MD

    2009-01-01

    Full Text Available In May 2005 a 68-year-old woman received a VDD pacemaker implantation in the right pectoral region at our hospital for the treatment of complete atrioventricular block. In July 2008, she was diagnosed with dilated cardiomyopathy based on histological testing. In November 2008, she developed syncope due to ventricular tachycardia while at another hospital. She underwent external electrical cardioversion with an anterior-lateral paddle position using a single shock of 100 J. This shock led to severe bradycardia resulting in a transfer to our hospital. The physician who provided the shock could not have been aware that the patient had an implanted pacemaker. The skin above the pulse generator was burned. The electrocardiogram showed no pacing spikes or ventricular escape rhythm. Investigation of the pacemaker 3 hours after cardioversion revealed reprogramming of the device and a marked rise in the lead impedance (>3,000 ohm. Removal of the generator and implantation of a biventricular cardioverter defibrillator were required. The emergency situation, the small size of the generator, the small incision made using the buried suture method, and the patient's obesity all probably contributed to the physician's not noticing the implanted pacemaker. It is important to increase awareness of the severe consequences that may follow if the physician administering external defibrillation does not know about the patient's implanted pacemaker.

  11. Recovery of Ventriculo-Atrial Conduction after Adrenaline in Patients Implanted with Pacemakers.

    Science.gov (United States)

    Cismaru, Gabriel; Gusetu, Gabriel; Muresan, Lucian; Rosu, Radu; Andronache, Marius; Matuz, Roxana; Puiu, Mihai; Mester, Petru; Miclaus, Maria; Pop, Dana; Mircea, Petru Adrian; Zdrenghea, Dumitru

    2015-07-01

    Ventriculo-atrial (VA) conduction can have negative consequences for patients with implanted pacemakers and defibrillators. There is concern whether impaired VA conduction could recover during stressful situations. Although the influence of isoproterenol and atropine are well established, the effect of adrenaline has not been studied systematically. The objective of this study was to determine if adrenaline can facilitate recovery of VA conduction in patients implanted with pacemakers. A prospective study was conducted on 61 consecutive patients during a 4-month period (April-July 2014). The presence of VA conduction was assessed during the pacemaker implantation procedure. In case of an impaired VA conduction, adrenaline infusio was used as a stress surrogate to test conduction recovery. The indications for pacemaker implantation were: sinus node dysfunction in 18 patients, atrioventricular (AV) block in 40 patients, binodal dysfunction (sinus node+ AV node) in two patients and other (carotid sinus syndrome) in one patient. In the basal state, 15/61 (24.6%) presented spontaneous VA conduction and 46/61 (75.4%) had no VA conduction. After administration of adrenaline, there was VA conduction recovery in 5/46 (10.9%) patients. Adrenaline infusion produced recovery of VA conduction in 10.9% of patients with absent VA conduction in a basal state. Recovery of VA conduction during physiological or pathological stresses could be responsible for the pacemaker syndrome, PMT episodes, or certain implantable cardiac defibrillator detection issues. © 2015 Wiley Periodicals, Inc.

  12. Can neuroimaging disentangle bipolar disorder?

    Science.gov (United States)

    Hozer, Franz; Houenou, Josselin

    2016-05-01

    Bipolar disorder heterogeneity is large, leading to difficulties in identifying neuropathophysiological and etiological mechanisms and hindering the formation of clinically homogeneous patient groups in clinical trials. Identifying markers of clinically more homogeneous groups would help disentangle BD heterogeneity. Neuroimaging may aid in identifying such groups by highlighting specific biomarkers of BD subtypes or clinical dimensions. We performed a systematic literature search of the neuroimaging literature assessing biomarkers of relevant BD phenotypes (type-I vs. II, presence vs. absence of psychotic features, suicidal behavior and impulsivity, rapid cycling, good vs. poor medication response, age at onset, cognitive performance and circadian abnormalities). Consistent biomarkers were associated with suicidal behavior, i.e. frontal/anterior alterations (prefrontal and cingulate grey matter, prefrontal white matter) in patients with a history of suicide attempts; and with cognitive performance, i.e. involvement of frontal and temporal regions, superior and inferior longitudinal fasciculus, right thalamic radiation, and corpus callosum in executive dysfunctions. For the other dimensions and sub-types studied, no consistent biomarkers were identified. Studies were heterogeneous both in methodology and outcome. Though theoretically promising, neuroimaging has not yet proven capable of disentangling subtypes and dimensions of bipolar disorder, due to high between-study heterogeneity. We issue recommendations for future studies. Copyright © 2016 Elsevier B.V. All rights reserved.

  13. A Fractional Bipolar Radiofrequency Device Combined with a Bipolar Radiofrequency and Infrared Light Treatment for Improvement in Facial Wrinkles and Overall Skin Tone and Texture.

    Science.gov (United States)

    Gold, Alan H; Pozner, Jason; Weiss, Robert

    2016-10-01

    A variety of techniques and energy-based technologies are currently utilized for the treatment of facial wrinkles. Fractional bipolar radiofrequency treatment and treatment with bipolar radiofrequency combined with infrared light have both been reported to be safe and effective for the non-invasive treatment of wrinkles and overall facial rejuvenation. A multicenter, prospective clinical trial evaluated a protocol of treatment with a device incorporating bipolar radiofrequency and infrared light followed by treatment with a fractional bipolar radiofrequency device for facial wrinkle reduction and improvement in the overall appearance of aged facial skin. Fifty-six patients with mild to moderate facial wrinkles received three full-face treatments (forehead, nose, cheeks, periorbital, and perioral areas) at 4 to 6 week intervals and were evaluated at 12 and 24 weeks after the last treatment. Clinical photographs at baseline and follow-ups were assessed by both the investigators and patients using the Global Aesthetic Improvement scale. Treatment safety was evaluated. Study participants also completed a satisfaction and improvement questionnaire. Fitzpatrick Wrinkling and Elastosis Score was decreased significantly at three months (P radiofrequency and infrared light treatment followed by fractionated bipolar radiofrequency treatment results in safe, well tolerated, and effective improvement in overall skin tone and texture and reduction of facial wrinkles. 4 Therapeutic. © 2016 The American Society for Aesthetic Plastic Surgery, Inc. Reprints and permission: journals.permissions@oup.com.

  14. Brief Report: A Family Risk Study Exploring Bipolar Spectrum Problems and Cognitive Biases in Adolescent Children of Bipolar Parents

    Science.gov (United States)

    Espie, Jonathan; Jones, Steven H.; Vance, Yvonne H.; Tai, Sara J.

    2012-01-01

    Children of parents with bipolar disorder are at increased risk of bipolar spectrum diagnoses. This cross-sectional study explores cognitive factors in the prediction of vulnerability to bipolar disorder. Adolescents at high-risk (with a parent with bipolar disorder; n = 23) and age and gender matched adolescents (n = 24) were recruited. Parent…

  15. Lower switch rate in depressed patients with bipolar II than bipolar I disorder treated adjunctively with second-generation antidepressants

    NARCIS (Netherlands)

    Altshuler, LL; Suppes, T; Nolen, WA; Leverich, G; Keck, PE; Frye, MA; Kupka, R; McElroy, SL; Grunze, H; Kitchen, CMR; Post, R; Black, D.O.

    Objectives: The authors compared the switch rate into hypomania/mania in depressed patients treated with second-generation antidepressants who had either bipolar I or bipolar II disorder. Method: In a 10-week trial, 184 outpatients with bipolar depression (134 with bipolar I disorder, 48 with

  16. Innovative approaches to bipolar disorder and its treatment

    Science.gov (United States)

    Cipriani, Andrea; Harmer, Catherine J.; Nobre, Anna C.; Saunders, Kate; Goodwin, Guy M.; Geddes, John R.

    2016-01-01

    All psychiatric disorders have suffered from a dearth of truly novel pharmacological interventions. In bipolar disorder, lithium remains a mainstay of treatment, six decades since its effects were serendipitously discovered. The lack of progress reflects several factors, including ignorance of the disorder's pathophysiology and the complexities of the clinical phenotype. After reviewing the current status, we discuss some ways forward. First, we highlight the need for a richer characterization of the clinical profile, facilitated by novel devices and new forms of data capture and analysis; such data are already promoting a reevaluation of the phenotype, with an emphasis on mood instability rather than on discrete clinical episodes. Second, experimental medicine can provide early indications of target engagement and therapeutic response, reducing the time, cost, and risk involved in evaluating potential mood stabilizers. Third, genomic data can inform target identification and validation, such as the increasing evidence for involvement of calcium channel genes in bipolar disorder. Finally, new methods and models relevant to bipolar disorder, including stem cells and genetically modified mice, are being used to study key pathways and drug effects. A combination of these approaches has real potential to break the impasse and deliver genuinely new treatments. PMID:27111134

  17. Violence in schizophrenia and bipolar disorder.

    Science.gov (United States)

    Volavka, Jan

    2013-03-01

    Although most psychiatric patients are not violent, serious mental illness is associated with increased risk of violent behavior. Most of the evidence available pertains to schizophrenia and bipolar disorder. MEDLINE data base was searched for articles published between 1966 and November 2012 using the combination of key words 'schizophrenia' or 'bipolar disorder' with 'aggression' or 'violence'. For the treatment searches, generic names were used in combination with key words 'schizophrenia' or 'bipolar disorder' and 'aggression' No language constraint was applied. Only articles dealing with adults were included. The lists of references were searched manually to find additional articles. There were statistically significant increases of risk of violence in schizophrenia and in bipolar disorder in comparison with general population. The evidence suggests that the risk of violence is greater in bipolar disorder than in schizophrenia. Most of the violence in bipolar disorder occurs during the manic phase. The risk of violence in schizophrenia and bipolar disorder is increased by comorbid substance use disorder. Violence among adults with schizophrenia may follow at least two distinct pathways-one associated with antisocial conduct, and another associated with the acute psychopathology of schizophrenia. Clozapine is the most effective treatment of aggressive behavior in schizophrenia. Emerging evidence suggests that olanzapine may be the second line of treatment. Treatment adherence is of key importance. Non-pharmacological methods of treatment of aggression in schizophrenia and bipolar disorder are increasingly important. Cognitive behavioral approaches appear to be effective in cases where pharmacotherapy alone does not suffice. Violent behavior of patients with schizophrenia and bipolar disorder is a public health problem. Pharmacological and non-pharmacological approaches should be used to treat not only violent behavior, but also contributing comorbidities such

  18. Complete Congenital Heart Block in a Neonatal Lupus Erythematosus Associated with Pulmonary Involvement without Pacemaker Implantation: A Case Report

    Directory of Open Access Journals (Sweden)

    Yazdan Ghandi

    2016-10-01

    Conclusion: This case report was conducted on a newborn with CCHB associated with pulmonary disorder. The newborn was intubated due to respiratory distress and did not need pacemaker implantation; however, after 8-month follow up, excellent outcomes were observed. It seems that atelectasis and mechanical ventilation can intolerance, and pacemaker implantation did not need in NLE with CCHB with narrowing QRS complex.

  19. Trends in service time of pacemakers in the Netherlands : A long-term nationwide follow-up study

    NARCIS (Netherlands)

    de Vries, L. M.; Leening, M. J. G.; Dijk, W. A.; Hooijschuur, C. A. M.; Stricker, B. H. C.; van Hemel, N. M.

    2017-01-01

    Aims: After decades of experience and strongly improved technology, service time of pacemaker generators is expected to increase. To test this hypothesis, we conducted a retrospective review of a large cohort of patients with a pacemaker. Methods: We reviewed data collected between 1984 and 2006 in

  20. Trends in service time of pacemakers in the Netherlands: A long-term nationwide follow-up study

    NARCIS (Netherlands)

    L.M. de Vries (Laura); M.J.G. Leening (Maarten); W.A. Dijk (Arnold); C.A.M. Hooijschuur (C. A M); B.H.Ch. Stricker (Bruno); N.M. van Hemel (Norbert)

    2017-01-01

    textabstractAims After decades of experience and strongly improved technology, service time of pacemaker generators is expected to increase. To test this hypothesis, we conducted a retrospective review of a large cohort of patients with a pacemaker. Methods We reviewed data collected between 1984

  1. Short- and long-term need for permanent pacemaker after transcatheter implantation of the Edwards Sapien aortic valve prosthesis.

    Science.gov (United States)

    Moreno, Raúl; Calvo, Luis; Sánchez-Recalde, Angel; Galeote, Guillermo; Jiménez-Valero, Santiago; López, Teresa; Plaza, Ignacio; González-Davia, Rosa; Ramírez, Ulises; Mesa, Jose Maria; Moreno-Gomez, Isidro; López-Sendón, José-Luis

    2015-11-01

    A permanent pacemaker is frequently needed after transcatheter aortic valve implantation, but the available data are mainly on the CoreValve system. To evaluate the need for new permanent pacemaker after implantation of the Edwards Sapien device, as well as related factors. We included the first 100 patients treated with the Edwards Sapien device at our institution. Of these, 12 had a permanent pacemaker before the procedure, and thus our study population was the remaining 88 patients. A permanent pacemaker was indicated in eight patients (9.1%) during hospitalization or at 30 days. After discharge, another four patients needed a pacemaker (at 42 days and three, 18, and 30 months). Two variables were associated with the need for pacemaker during hospitalization: previous dialysis (13% vs. 1%, p=0.042) and complete right bundle branch block before the procedure (25% vs. 5%, p=0.032). More than one month after the procedure, the characteristics associated with the need for pacemaker were plasma creatinine level (2.5±1.7 vs. 1.3±0.6 mg/dl, p=0.001) and previous myocardial infarction (50% vs. 10%, p=0.013). The rate of pacemaker implantation with the Edwards Sapien device was 9.1%. Right bundle branch block and dialysis were associated with this complication.

  2. Cardiac MRI in patients with complex CHD following primary or secondary implantation of MRI-conditional pacemaker system.

    Science.gov (United States)

    Al-Wakeel, Nadya; O h-Ici, Darach; Schmitt, Katharina R; Messroghli, Daniel R; Riesenkampff, Eugénie; Berger, Felix; Kuehne, Titus; Peters, Bjoern

    2016-02-01

    In patients with CHD, cardiac MRI is often indicated for functional and anatomical assessment. With the recent introduction of MRI-conditional pacemaker systems, cardiac MRI has become accessible for patients with pacemakers. The present clinical study aims to evaluate safety, susceptibility artefacts, and image reading of cardiac MRI in patients with CHD and MRI-conditional pacemaker systems. Material and methods CHD patients with MRI-conditional pacemaker systems and a clinical need for cardiac MRI were examined with a 1.5-T MRI system. Lead function was tested before and after MRI. Artefacts and image readings were evaluated using a four-point grading scale. A total of nine patients with CHD (mean age 34.0 years, range 19.5-53.6 years) received a total of 11 cardiac MRI examinations. Owing to clinical indications, seven patients had previously been converted from conventional to MRI-conditional pacemaker systems. All MRI examinations were completed without adverse effects. Device testing immediately after MRI and at follow-up showed no alteration of pacemaker device and lead function. Clinical questions could be addressed and answered in all patients. Cardiac MRI can be performed safely with high certainty of diagnosis in CHD patients with MRI-conditional pacemaker systems. In case of clinically indicated lead and box changing, CHD patients with non-MRI-conditional pacemaker systems should be considered for complete conversion to MRI-conditional systems.

  3. The proportion of asymptomatic recurrence after catheter ablation of atrial fibrillation in patients with a pacemaker for sick sinus syndrome

    Directory of Open Access Journals (Sweden)

    Yuki Osaka

    2017-09-01

    Conclusions: One-third of PAF patients with SSS and pacemakers recurred after multiple CA sessions. However, 65% of them were asymptomatic and difficult to be identified with conventional follow-up. Pacemaker interrogation significantly increased the detection rate of AF-recurrence.

  4. Prospective longitudinal course of aggression among adults with bipolar disorder

    Science.gov (United States)

    Ballester, Javier; Goldstein, Benjamin; Goldstein, Tina R; Yu, Haifeng; Axelson, David; Monk, Kelly; Hickey, Mary Beth; Diler, Rasim S; Sakolsky, Dara J; Sparks, Garrett; Iyengar, Satish; Kupfer, David J; Brent, David A; Birmaher, Boris

    2014-01-01

    Objectives Bipolar disorder (BP) has been associated with increased aggressive behaviors. However, all existing studies are cross-sectional and include forensic or inpatient populations and many do not take into account the effects of comorbid conditions. The goal of this study was to evaluate the longitudinal course of aggression among adult outpatients with BP compared with non-BP patients and healthy controls. Methods Subjects with bipolar I disorder (BP-I)/bipolar II disorder (BP-II) (n = 255), non-BP psychopathology (n = 85), and healthy controls (n = 84) (average 38.9 years, 78.7% female, and 84.9% Caucasian) were evaluated at intake and after two- and four-years of follow-up. Aggression was self-rated using the Aggression Questionnaire (AQ). Comparisons were adjusted for any significant demographic and clinical differences and for multiple comparisons. For subjects with BP, associations of AQ with subtype of BP, current versus past mood episodes, polarity and severity of the current episode, psychosis, and current pharmacological treatment were evaluated. Results In comparison with subjects with non-BP psychiatric disorders and healthy controls, subjects with BP showed persistently higher total and subscale AQ scores (raw and T-scores) during the four-year follow-up. There were no effects of BP subtype, severity or polarity of the current episode, psychosis, and current pharmacological treatments. Subjects in an acute mood episode showed significantly higher AQ scores than euthymic subjects. Conclusions BP, particularly during acute episodes, is associated with increased self-reported verbal and physical aggression, anger, and hostility. These results provide further evidence for the need of treatments to prevent mood recurrences and prompt treatment of acute mood episodes in subjects with BP. PMID:24372913

  5. Clinical and diagnostic implications of lifetime attention-deficit/hyperactivity disorder comorbidity in adults with bipolar disorder: data from the first 1000 STEP-BD participants.

    Science.gov (United States)

    Nierenberg, Andrew A; Miyahara, Sachiko; Spencer, Tom; Wisniewski, Stephen R; Otto, Michael W; Simon, Naomi; Pollack, Mark H; Ostacher, Michael J; Yan, Leslie; Siegel, Rebecca; Sachs, Gary S

    2005-06-01

    Systematic studies of children and adolescents with a diagnosis of bipolar disorder show that rates of attention-deficit/hyperactivity disorder (ADHD) range from 60% to 90%, but the prevalence and implications of ADHD in adults with bipolar disorder are less clear. The first consecutive 1000 adults with bipolar disorder enrolled in the National Institute of Mental Health's Systematic Treatment Enhancement Program for Bipolar Disorder (STEP-BD) were assessed for lifetime ADHD. The retrospective course of bipolar disorder, current mood state, and prevalence of other comorbid psychiatric diagnoses were compared for the groups with and without lifetime comorbid ADHD. The overall lifetime prevalence of comorbid ADHD in this large cohort of bipolar patients was 9.5% (95% confidence interval 7.6%-11.4%); 14.7% of male patients and 5.8% of female patients with bipolar disorder had lifetime ADHD. Patients with bipolar disorder and ADHD had the onset of their mood disorder approximately 5 years earlier. After adjusting for age of onset, those with ADHD comorbidity had shorter periods of wellness and were more frequently depressed. We found that patients with bipolar disorder comorbid with ADHD had a greater number of other comorbid psychiatric diagnoses compared with those without comorbid ADHD, with substantially higher rates of several anxiety disorders and alcohol and substance abuse and dependence. Lifetime ADHD is a frequent comorbid condition in adults with bipolar disorder, associated with a worse course of bipolar disorder and greater burden of other psychiatric comorbid conditions. Studies are needed that focus on the efficacy and safety of treating ADHD comorbid with bipolar disorder.

  6. Bipolar II disorder as a risk factor for postpartum depression.

    Science.gov (United States)

    Mandelli, Laura; Souery, Daniel; Bartova, Lucie; Kasper, Siegfried; Montgomery, Stuart; Zohar, Joseph; Mendlewicz, Julien; Serretti, Alessandro

    2016-11-01

    There is evidence for a bipolar diathesis in postpartum depression (PPD) and women presenting with a first PPD frequently receive a diagnosis of bipolar type II disorder (BD-II). However formal evidence for an association between BD-II and PPD has not yet been reported. In the present study we tested a potential association between BD-II and PPD. Parous women with a diagnosis of bipolar type I disorder (BD-I) (n=93), BD-II (n=36) or major depressive disorder (MDD) (n=444) were considered in the present study. All women were retrospectively evaluated for history of PPD (DSM-IV criteria) and other clinical and socio-demographic features. Women with a history of PDD (n=139, 24%) were younger, younger at illness onset and had more family history for BD compared to women without history of PPD (n=436, 75.9%). Half of BD-II women reported PPD (50%), compared to less than one-third of BD-I and MDD women (respectively 27.5% and 21.6%) (p=0.004). Limitations include the retrospective assessment of PPD and no available data about the timing of postpartum episodes, illness onset or psychiatric care before or after childbirth, and the number of postpartum episodes. BD-II may confer a remarkable risk for PPD, which may be even higher than that of women affected by BD-I disorder. Careful monitoring of BD-II women during the pregnancy and postpartum period, as well as assessment of bipolar features in women with a PPD without a current diagnosis of BD are recommended. Copyright © 2016 Elsevier B.V. All rights reserved.

  7. ESPECTRA: Searching the Bipolar Spectrum in Eating Disorder patients

    Directory of Open Access Journals (Sweden)

    Moreno Ricardo A

    2011-04-01

    Full Text Available Abstract Background Bipolar Disorder (BD is a chronic, recurrent and highly prevalent illness. Despite the need for correct diagnosis to allow proper treatment, studies have shown that reaching a diagnosis can take up to ten years due to the lack of recognition of the broader presentations of BD. Frequent comorbidities with other psychiatric disorders are a major cause of misdiagnosis and warrant thorough evaluation. Methods/Design ESPECTRA (Occurrence of Bipolar Spectrum Disorders in Eating Disorder Patients is a single-site cross-sectional study involving a comparison group, designed to evaluate the prevalence of bipolar spectrum in an eating disorder sample. Women aged 18-45 years will be evaluated using the SCID-P and Zurich criteria for diagnosis and the HAM-D, YOUNG, SCI-MOODS, HCL-32, BIS-11, BSQ, WHOQoL and EAS instruments for rating symptoms and measuring clinical correlates. Discussion The classificatory systems in psychiatry are based on categorical models that have been criticized for simplifying the diagnosis and leading to an increase in comorbidities. Some dimensional approaches have been proposed aimed at improving the validity and reliability of psychiatric disorder assessments, especially in conditions with high rates of comorbidity such as BD and Eating Disorder (ED. The Bipolar Spectrum (BS remains under-recognized in clinical practice and its definition is not well established in current diagnostic guidelines. Broader evaluation of psychiatric disorders combining categorical and dimensional views could contribute to a more realistic understanding of comorbidities and help toward establishing a prognosis.

  8. Tratamento do transtorno bipolar: eutimia Bipolar disorder treatment: euthymia

    Directory of Open Access Journals (Sweden)

    Fábio Gomes de Matos e Souza

    2005-01-01

    Full Text Available O transtorno bipolar é um quadro complexo caracterizado por episódios de depressão, mania ou hipomania e fases assintomáticas. O tratamento visa ao controle de episódios agudos e prevenção de novos episódios. O tratamento farmacológico iniciou-se com o lítio. Até o momento, o lítio permanece como o tratamento com mais evidências favoráveis na fase de manutenção. Outros tratamentos demonstram eficácia nessa fase, como o valproato, a carbamazepina e os antipsicóticos atípicos. Dos antipsicóticos atípicos o mais estudado nesta fase do tratamento é a olanzapina. Mais estudos prospectivos são necessários para confirmar a ação profilática de novos agentes.Bipolar disorder is a complex disorder characterized by depression episodes, mania or hypomania and asymptomatic phases. The treatment aims at the control of acute episodes and prevention of new episodes. The pharmacological treatment was inaugurated with lithium. Until the moment, lithium remains as the treatment with more favorable evidences in the maintenance phase. Other treatments demonstrate efficacy in this phase, as valproate, carbamazepine and atypical antipsychotics. Of the atypical antipsychotics, the most studied in this phase of treatment is olanzapine. More prospective studies are necessary to confirm prophylactic action of new agents.

  9. Ionizing radiations simulation on bipolar components

    International Nuclear Information System (INIS)

    Montagner, X.

    1999-01-01

    This thesis presents the ionizing radiation effects on bipolar components and more specially their behavior facing the total dose. The first part is devoted to the radiation environments with a special attention to the spatial environments and new emergent environments. The specificities of bipolar components are then presented and their behavior facing the interactions. The physical mechanisms bound to the dose rate are also discussed. The second part presents a physical analysis of degradations induced by the cumulated dosimetry on bipolar components and simulation with the ATLAS code. The third part exposes an electric empirical simulation induced by the cumulated dose in static conditions. (A.L.B.)

  10. Bipolar Disorder and Early Affective Trauma.

    Science.gov (United States)

    de Codt, Aloise; Monhonval, Pauline; Bongaerts, Xavier; Belkacemi, Ikram; Tecco, Juan Martin

    2016-09-01

    Bipolar disorder is a chronic psychiatric disease with a high prevalence and is a major psychosocial and medical burden. The exact etiological pathways of bipolar disorder are not fully understood. Genetic factors are known to play an important role in the etiology of bipolar disorder. However, high rates of discordance among identical twins and a growing body of evidence that environmental factors such as early stress can influence the onset and course of psychiatric diseases underline the importance of additional etiological mechanisms of bipolar disorders. There has been little investigation about early trauma in bipolar disorder. The aim of this study was to review the literature on the association between early traumatic interactions like child neglect, mistreatment, abuse or early parental separation and the occurrence of bipolar disorder in adulthood or impact on the course of the disease. Studies investigating associations between child neglect, mistreatment, abuse or early parental separation and occurrence of bipolar disorder in adulthood or impact on the course of the disease were searched in the Pubmed database. More than 700 articles were sorted independently by two of the authors using predefined criteria. Only research articles, reviews and meta-analyses were selected for this review. 53 articles met the inclusion criteria. To date, four systematic reviews partially addressed our research question. Early trauma is more frequently found in the past of bipolar patients than in the general population. Studies support a harmful effect of childhood trauma on the course of bipolar disease, with more anxious, depressive or psychotic symptoms, an early age of onset and a worse prognosis. Early trauma is more often found in the past of bipolar adult patients than the general population and studies support a harmful effect of childhood trauma on the course of bipolar disease, with more anxious, depressive or psychotic symptoms, an early age of onset and a

  11. Cognitive Behavioral Therapy in Bipolar Disorder

    Directory of Open Access Journals (Sweden)

    Zeynep Mackali

    2011-12-01

    Full Text Available Bipolar disorder is an early-onset, chronic disorder. It impairs occupational, social, and family functioning, which makes learning to adapt living with the disorder and its treatment critically important. Therefore, it has now become common knowledge that psychosocial interventions are also necessary in the treatment of bipolar disorder adjunctive to pharmacotherapy. Thus, whichever psychosocial interventions are more effective in bipolar disorder is a crucial research question. In this article, cognitive-behavioral therapy, which is applied adjunctive to pharmacotherapy, will be addressed and the findings of research about the effectiveness of these applications will be reviewed.

  12. Clinicians' assessments of bipolar disorder and substance abuse as predictors of suicidal behavior in acutely hospitalized psychiatric inpatients.

    Science.gov (United States)

    Comtois, Katherine Anne; Russo, Joan E; Roy-Byrne, Peter; Ries, Richard K

    2004-11-15

    Suicide is a major risk for those with bipolar disorder, a risk amplified by comorbid substance abuse in some, but not all, previous studies. To further explore the relationships of substance abuse, suicide, and bipolarity as they present in clinical practice, we analyzed standardized clinical data from a large acute psychiatric inpatient service. Standardized clinical evaluations of 7819 patients with diagnoses of bipolar depression (n=990), bipolar mania (n=948), unipolar depressive episode (n=3626), or schizophrenia-schizoaffective disorders (n=2255) were analyzed to evaluate the relationship between current substance-use problems, substance-induced symptoms, and a current suicide crisis, as well as lifetime suicide attempts, with logistic regressions adjusting for age, gender, and ethnicity. Across the combined groups, current substance-use problems were significantly associated with a lifetime suicide attempt (odds ratios [ORs] 1.6-2.5) and to a lesser degree to the admission suicide crisis (ORs 1-2.2). Among bipolar (depressed/manic) patients, but not other diagnostic groups, those with both current substance-use problems and substance-induced symptoms had even higher rates of a recent suicide crisis (ORs 1.5-3.1) and of a lifetime attempt (ORs 2.5-3.4). In bipolar patients, substance use disorder doubled and substance use disorder plus substance-induced symptoms tripled the suicidal risk. Implications for future research are discussed.

  13. [The computer assisted pacemaker clinic at the regional hospital of Udine (author's transl)].

    Science.gov (United States)

    Feruglio, G A; Lestuzzi, L; Carminati, D

    1978-01-01

    For a close follow-up of large groups of pacemaker patients and for evaluation of long term pacing on a reliable statistical basis, many pacemaker centers in the world are now using computer systems. A patient data system with structured display records, designed to give complete, comprehensive and surveyable information and which are immediately retrievable 24 hours a day, on display or printed sets, seems to offer an ideal solution. The pacemaker clinic at the Regional Hospital of Udine has adopted this type of system. The clinic in linked to a live, on-line patient data system (G/3, Informatica Friuli-Venezia Giulia). The input and retrieval of information are made through a conventional keyboard. The input formats have fixed headings with coded alternatives and a limited space for comments in free text. The computer edits the coded information to surveyable reviews. Searches can be made on coded information and data of interest.

  14. A Parametric Computational Model of the Action Potential of Pacemaker Cells.

    Science.gov (United States)

    Ai, Weiwei; Patel, Nitish D; Roop, Partha S; Malik, Avinash; Andalam, Sidharta; Yip, Eugene; Allen, Nathan; Trew, Mark L

    2018-01-01

    A flexible, efficient, and verifiable pacemaker cell model is essential to the design of real-time virtual hearts that can be used for closed-loop validation of cardiac devices. A new parametric model of pacemaker action potential is developed to address this need. The action potential phases are modeled using hybrid automaton with one piecewise-linear continuous variable. The model can capture rate-dependent dynamics, such as action potential duration restitution, conduction velocity restitution, and overdrive suppression by incorporating nonlinear update functions. Simulated dynamics of the model compared well with previous models and clinical data. The results show that the parametric model can reproduce the electrophysiological dynamics of a variety of pacemaker cells, such as sinoatrial node, atrioventricular node, and the His-Purkinje system, under varying cardiac conditions. This is an important contribution toward closed-loop validation of cardiac devices using real-time heart models.

  15. Progression along the Bipolar Spectrum: A Longitudinal Study of Predictors of Conversion from Bipolar Spectrum Conditions to Bipolar I and II Disorders

    Science.gov (United States)

    Alloy, Lauren B.; Urošević, Snežana; Abramson, Lyn Y.; Jager-Hyman, Shari; Nusslock, Robin; Whitehouse, Wayne G.; Hogan, Michael

    2011-01-01

    Little longitudinal research has examined progression to more severe bipolar disorders in individuals with “soft” bipolar spectrum conditions. We examine rates and predictors of progression to bipolar I and II diagnoses in a non-patient sample of college-age participants (n = 201) with high General Behavior Inventory scores and childhood or adolescent onset of “soft” bipolar spectrum disorders followed longitudinally for 4.5 years from the Longitudinal Investigation of Bipolar Spectrum (LIBS) project. Of 57 individuals with initial cyclothymia or bipolar disorder not otherwise specified (BiNOS) diagnoses, 42.1% progressed to a bipolar II diagnosis and 10.5% progressed to a bipolar I diagnosis. Of 144 individuals with initial bipolar II diagnoses, 17.4% progressed to a bipolar I diagnosis. Consistent with hypotheses derived from the clinical literature and the Behavioral Approach System (BAS) model of bipolar disorder, and controlling for relevant variables (length of follow-up, initial depressive and hypomanic symptoms, treatment-seeking, and family history), high BAS sensitivity (especially BAS Fun Seeking) predicted a greater likelihood of progression to bipolar II disorder, whereas early age of onset and high impulsivity predicted a greater likelihood of progression to bipolar I (high BAS sensitivity and Fun-Seeking also predicted progression to bipolar I when family history was not controlled). The interaction of high BAS and high Behavioral Inhibition System (BIS) sensitivities also predicted greater likelihood of progression to bipolar I. We discuss implications of the findings for the bipolar spectrum concept, the BAS model of bipolar disorder, and early intervention efforts. PMID:21668080

  16. Superior transseptal approach to mitral valve is associated with a higher need for pacemaker implantation than the left atrial approach

    DEFF Research Database (Denmark)

    Lukac, Peter; Hjortdal, Vibeke E; Pedersen, Anders K

    2006-01-01

    retrospectively evaluated. The surgeons used either the superior transseptal (group A) or left atrial approach (group B). The risk of pacemaker implantation associated with the superior transseptal approach as compared with the left atrial approach was estimated using the multivariate Cox regression analysis...... to adjust for possible confounders. RESULTS: We included 577 patients, 150 in group A and 427 in group B. Forty-four patients had a pacemaker implanted after the surgery; 17 in group A and 27 in group B (p = 0.010). The superior transseptal approach was an independent risk factor of pacemaker implantation...... in multivariate analysis (hazard ratio 2.2 [1.2 to 4.1], p = 0.014). Nineteen patients had a pacemaker implanted because of sinus node dysfunction; 9 in group A and 10 in group B (p = 0.017). Group A was an independent predictor of pacemaker implantation because of sinus node dysfunction in bivariate analyses...

  17. Risk of pacemaker implantation subsequent to radiotherapy for early-stage breast cancer in Denmark, 1982-2005

    DEFF Research Database (Denmark)

    Rehammar, Jens Christian; Videbaek, L.; Brock Johansen, J.

    2015-01-01

    . Objectives: The aim of this study was to examine the risk of severe conduction abnormalities evaluated by implantation of a pacemaker, subsequent to breast cancer radiotherapy. Methods: From the database of the Danish Breast Cancer Collaborative Group, we identified women treated with radiotherapy for early......-stage breast cancer in Denmark from 1982 to 2005. By record linkage to the Danish Pacemaker and ICD Registry information was retrieved on pacemaker implants subsequent to radiotherapy. Rate ratios (RR) of pacemaker implantation for left versus right sided breast cancer were calculated. Results: Among 18......,308 women treated with radiotherapy for early-stage breast cancer, 179 women had a pacemaker implanted subsequent to radiotherapy, 90 in 9,315 left sided and 89 in 8,993 right sided breast cancers. The unadjusted RR was 1.02 (0.76-1.36 95% CI, p=0.91) and the RR adjusted for year, age and time since...

  18. Gene- and cell-based bio-artificial pacemaker: what basic and translational lessons have we learned?

    Science.gov (United States)

    Li, R A

    2012-06-01

    Normal rhythms originate in the sino-atrial node, a specialized cardiac tissue consisting of only a few thousands of nodal pacemaker cells. Malfunction of pacemaker cells due to diseases or aging leads to rhythm generation disorders (for example, bradycardias and sick-sinus syndrome (SSS)), which often necessitate the implantation of electronic pacemakers. Although effective, electronic devices are associated with such shortcomings as limited battery life, permanent implantation of leads, lead dislodging, the lack of autonomic responses and so on. Here, various gene- and cell-based approaches, with a particular emphasis placed on the use of pluripotent stem cells and the hyperpolarization-activated cyclic nucleotide-gated-encoded pacemaker gene family, that have been pursued in the past decade to reconstruct bio-artificial pacemakers as alternatives will be discussed in relation to the basic biological insights and translational regenerative potential.

  19. Autaptic pacemaker mediated propagation of weak rhythmic activity across small-world neuronal networks

    Science.gov (United States)

    Yilmaz, Ergin; Baysal, Veli; Ozer, Mahmut; Perc, Matjaž

    2016-02-01

    We study the effects of an autapse, which is mathematically described as a self-feedback loop, on the propagation of weak, localized pacemaker activity across a Newman-Watts small-world network consisting of stochastic Hodgkin-Huxley neurons. We consider that only the pacemaker neuron, which is stimulated by a subthreshold periodic signal, has an electrical autapse that is characterized by a coupling strength and a delay time. We focus on the impact of the coupling strength, the network structure, the properties of the weak periodic stimulus, and the properties of the autapse on the transmission of localized pacemaker activity. Obtained results indicate the existence of optimal channel noise intensity for the propagation of the localized rhythm. Under optimal conditions, the autapse can significantly improve the propagation of pacemaker activity, but only for a specific range of the autaptic coupling strength. Moreover, the autaptic delay time has to be equal to the intrinsic oscillation period of the Hodgkin-Huxley neuron or its integer multiples. We analyze the inter-spike interval histogram and show that the autapse enhances or suppresses the propagation of the localized rhythm by increasing or decreasing the phase locking between the spiking of the pacemaker neuron and the weak periodic signal. In particular, when the autaptic delay time is equal to the intrinsic period of oscillations an optimal phase locking takes place, resulting in a dominant time scale of the spiking activity. We also investigate the effects of the network structure and the coupling strength on the propagation of pacemaker activity. We find that there exist an optimal coupling strength and an optimal network structure that together warrant an optimal propagation of the localized rhythm.

  20. Runtime Verification of Pacemaker Functionality Using Hierarchical Fuzzy Colored Petri-nets.

    Science.gov (United States)

    Majma, Negar; Babamir, Seyed Morteza; Monadjemi, Amirhassan

    2017-02-01

    Today, implanted medical devices are increasingly used for many patients and in case of diverse health problems. However, several runtime problems and errors are reported by the relevant organizations, even resulting in patient death. One of those devices is the pacemaker. The pacemaker is a device helping the patient to regulate the heartbeat by connecting to the cardiac vessels. This device is directed by its software, so any failure in this software causes a serious malfunction. Therefore, this study aims to a better way to monitor the device's software behavior to decrease the failure risk. Accordingly, we supervise the runtime function and status of the software. The software verification means examining limitations and needs of the system users by the system running software. In this paper, a method to verify the pacemaker software, based on the fuzzy function of the device, is presented. So, the function limitations of the device are identified and presented as fuzzy rules and then the device is verified based on the hierarchical Fuzzy Colored Petri-net (FCPN), which is formed considering the software limits. Regarding the experiences of using: 1) Fuzzy Petri-nets (FPN) to verify insulin pumps, 2) Colored Petri-nets (CPN) to verify the pacemaker and 3) To verify the pacemaker by a software agent with Petri-network based knowledge, which we gained during the previous studies, the runtime behavior of the pacemaker software is examined by HFCPN, in this paper. This is considered a developing step compared to the earlier work. HFCPN in this paper, compared to the FPN and CPN used in our previous studies reduces the complexity. By presenting the Petri-net (PN) in a hierarchical form, the verification runtime, decreased as 90.61% compared to the verification runtime in the earlier work. Since we need an inference engine in the runtime verification, we used the HFCPN to enhance the performance of the inference engine.