WorldWideScience

Sample records for biplanar open-wedge high

  1. Leg length change after opening wedge and closing wedge high tibial osteotomy: A meta-analysis.

    Science.gov (United States)

    Kim, Jun-Ho; Kim, Hyun-Jung; Lee, Dae-Hee

    2017-01-01

    Theoretical considerations suggest that leg length increases after opening wedge high tibial osteotomy (HTO) and decreases after closing wedge HTO; however, in vivo studies have yielded conflicting results. This meta-analysis therefore assessed changes in leg length after opening wedge and closing wedge HTO. All studies comparing pre- and postoperative leg length in patients who underwent opening and/or closing wedge HTO were included. Two reviewers independently recorded data from each study in terms of sample size as well as preoperative and postoperative leg length of open wedge and/or closed wedge HTO groups. Four studies were included in the meta-analysis. Although pooled results showed leg length changes from before to after surgery were -6.93 mm (95% confidence interval [CI]: -17.53 to 3.67 mm; P = 0.20) in opening wedge HTO and 1.97 mm (95% CI: -7.13 to 11.07 mm; P = 0.67) in closing wedge HTO, respectively, these values were statistically not significant. However, the difference in the pooled mean leg length change from before to after surgery between opening wedge and closing wedge HTO was 8 mm, a difference that was significant (95% CI: 6.53 to 9.46 mm; Pleg length was not statistically significant for either opening or closing wedge HTO. However, leg length change from before to after surgery was 8 mm greater for opening wedge HTO than for closing wedge HTO.

  2. Early weight bearing versus delayed weight bearing in medial opening wedge high tibial osteotomy: a randomized controlled trial.

    Science.gov (United States)

    Lansdaal, Joris Radboud; Mouton, Tanguy; Wascher, Daniel Charles; Demey, Guillaume; Lustig, Sebastien; Neyret, Philippe; Servien, Elvire

    2017-12-01

    The need for a period of non-weight bearing after medial opening wedge high tibial osteotomy remains controversial. It is hypothesized that immediate weight bearing after medial opening wedge high tibial osteotomy would have no difference in functional scores at one year compared to delayed weight bearing. Fifty patients, median age 54 years (range 40-65), with medial compartment osteoarthritis, underwent a medial opening wedge high tibial osteotomy utilizing a locking plate without bone grafting. Patients were randomized into an Immediate or a Delayed (2 months) weight bearing group. All patients were assessed at one-year follow-up and the two groups compared. The primary outcome measure was the IKS score. Secondary outcome measures included the IKDC score, the VAS pain score and rate of complications. The functional scores significantly improved in both groups. The IKS score increased from 142 ± 31 to 171 ± 26 in the Immediate group (p bearing after medial opening wedge high tibial osteotomy had no effect on functional scores at 1 year follow-up and did not significantly increase the complication rate. Immediate weight bearing after medial opening wedge high tibial osteotomy appears to be safe and can allow some patients a quicker return to activities of daily living and a decreased convalescence period. II.

  3. Preoperative varus laxity correlates with overcorrection in medial opening wedge high tibial osteotomy.

    Science.gov (United States)

    Ogawa, Hiroyasu; Matsumoto, Kazu; Ogawa, Takahiro; Takeuchi, Kentaro; Akiyama, Haruhiko

    2016-10-01

    Medial opening wedge high tibial osteotomy (HTO) is a realignment of the lower limb. Despite accurate preoperative planning and careful surgical techniques, many HTOs result in alignment correction errors. These alignment correction errors may be due to soft tissue laxity around the knee such as varus or valgus laxity. The purpose of this study was to examine the relationship of varus and valgus laxity of the knee and alignment correction errors, and to have a formula to predict the subsequent degree of these correction errors. Fifty knees from 41 patients undergoing opening wedge HTO for knee osteoarthritis were involved. Standing full-length anteroposterior radiographs of the lower limb and the tibia, and varus and valgus stress radiographs of the knee were used to evaluate alignment and joint laxity. Parameters were global correction (the change in the hip-knee-ankle angle), bony correction (the change in the medial proximal tibial angle), and soft tissue correction (global correction - bony correction). The average of global correction, bony correction, and soft tissue correction were 12.8° ± 4.3°, 9.4° ± 3.2°, and 3.4° ± 2.5°, respectively. Preoperative varus laxity was moderately correlated with soft tissue correction (R = 0.58), and in which the slope of the line in the scatter plot represented 0.59, implying that soft tissue correction increases by 0.59° for every 1° of preoperative varus laxity. Preoperative varus laxity is correlated with soft tissue correction, suggesting that more accurate alignment correction could be achieved by surgical planning taking into account preoperative varus laxity as a factor of soft tissue correction.

  4. Open Wedge High Tibial Osteotomy with Distal Tubercle Osteotomy Lessens Change in Patellar Position

    Directory of Open Access Journals (Sweden)

    Hoon Park

    2017-01-01

    Full Text Available The purpose of this study was to investigate the change in patellar position after open wedge high tibial osteotomy (OWHTO with distal tubercle osteotomy (DTO, comparing outcomes of conventional OWHTO in young adults with proximal tibia varus deformity but no arthritic manifestations. Thirty-three patients (mean age, 31.8 years subjected to OWHTO/DTO were matched with 30 patients (mean age, 33.5 years undergoing conventional OWHTO. Patellar position, as measured in pre- and postoperative standing lateral radiographs, was compared. Patellar height was assessed via Insall-Salvati ratio, modified Insall-Salvati ratio, Blackburne-Peel (BP index, Caton-Deschamps (CD index, and modified Miura-Kawamura index. Computed tomography was used to measure lateral patellar tilt and shift. In the OWHTO group, all patellar height indices decreased significantly following surgery. Although mean values of BP and CD indices decreased significantly in the OWHTO/DTO group, other determinants of patellar height showed no significant postoperative differences. Significant postoperative declines in average lateral patellar tilt were also evident in both groups, but pre- and postoperative lateral patellar shift did not differ significantly. OWHTO/DTO can be performed without significant changes in patellar height. The results obtained support that OWHTO/DTO is suitable for relatively young patients with proximal tibia vara but no arthritic change.

  5. High Rate of Recurrence Following Proximal Medial Opening Wedge Osteotomy for Correction of Moderate Hallux Valgus.

    Science.gov (United States)

    Iyer, Sravisht; Demetracopoulos, Constantine A; Sofka, Carolyn M; Ellis, Scott J

    2015-07-01

    The proximal medial opening wedge (PMOW) osteotomy has become more popular to treat moderate to severe hallux valgus with the recent development of specifically designed, low-profile modular plates. Despite the promising results previously reported in the literature, we have noted a high incidence of recurrence in patients treated with a PMOW. The purpose of this study was to report the clinical and radiographic outcomes of an initial cohort of patients treated with a PMOW osteotomy for moderate hallux valgus. We retrospectively analyzed prospectively gathered data on a cohort of 17 consecutive patients who were treated by the senior author using a PMOW osteotomy for moderate hallux valgus deformity. Average time to follow-up was 2.4 years (range, 1.0-3.5 years). The intermetatarsal angle (IMA), the hallux valgus angle (HVA), and the distal metatarsal articular angle (DMAA) were assessed on standard weightbearing radiographs of the foot preoperatively and at all follow-up visits. The Foot and Ankle Outcome Score (FAOS) was collected on all patients preoperatively and at final follow-up. Despite demonstrating good correction of their deformity initially, 11 of the 17 patients (64.7%) had evidence of recurrence of their hallux valgus deformity at final follow-up. Patients who recurred had a greater preoperative HVA (P = .023) and DMAA (P = .049) than patients who maintained their correction. Improvement in the quality-of-life subscale of the FAOS was noted at final follow-up for all patients (P = .05). There was no significant improvement in any of the other FAOS subscales. There was a high rate of recurrence of the hallux valgus deformity in this cohort of patients. Recurrence was associated with greater preoperative deformity and an increased preoperative DMAA. The PMOW without a concomitant distal metatarsal osteotomy may be best reserved for patients with mild hallux valgus deformity without an increased DMAA. Level IV, retrospective case series. © The Author

  6. Effect of Computer Navigation on Accuracy and Reliability of Limb Alignment Correction following Open-Wedge High Tibial Osteotomy: A Meta-Analysis

    OpenAIRE

    Han, Seung-Beom; Kim, Hyun Jung; Lee, Dae-Hee

    2017-01-01

    Background It is unclear whether computer navigation can improve the accuracy and reliability of targeted lower limb alignment correction following open-wedge high tibial osteotomy (HTO). This meta-analysis was designed to compare the accuracy and reliability of limb alignment correction between computer navigated and conventional open-wedge HTOs. Methods Studies that compared postoperative coronal alignment, including mechanical axis (MA) and weight bearing line (WBL) ratio, outliers of alig...

  7. Reliability of the imaging software in the preoperative planning of the open-wedge high tibial osteotomy.

    Science.gov (United States)

    Lee, Yong Seuk; Kim, Min Kyu; Byun, Hae Won; Kim, Sang Bum; Kim, Jin Goo

    2015-03-01

    The purpose of this study was to verify a recently developed picture-archiving and communications system-photoshop method by comparing reliabilities between real-size paper template and the PACS-photoshop methods in preoperative planning of open-wedge high tibial osteotomy. A prospective case series was conducted, including patients with medial osteoarthritis undergoing open-wedge high tibial osteotomy. In the preoperative planning, the picture-archiving and communications system-photoshop method and real-size paper template method were used simultaneously in all patients. Preoperative hip-knee-ankle angle, height, and angle of the osteotomy were evaluated. The reliability of this newly devised method was evaluated, and the consistency between the two methods was also evaluated using intra-class correlation coefficient. Using the picture-archiving and communications system-photoshop method, the mean correction angle and height of osteotomy gap of rater-1 were 11.7° ± 3.6° and 10.7 ± 3.6 mm, respectively. The mean correction angle and height of osteotomy gap of rater-2 were 12.0 ± 2.6 and 10.8 ± 3.6, respectively. The inter- and intra-rater reliabilities of the correction angle were 0.956 ~ 0.979 and 0.980 ~ 0.992, respectively. The inter- and intra-rater reliabilities of the height of the osteotomy gap were 0.968 ~ 0.985 and 0.971 ~ 0.994, respectively (p photoshop method, mean values of the correction angle and height of the osteotomy gap were 11.9° ± 3.6° and 10.8 ± 3.6 mm, respectively. Consistency between the two methods by comparing the means of the correction angle and the height of the osteotomy gap were 0.985 and 0.985, respectively (p photoshop method enables direct measurement of the height of the osteotomy gap with high reliability.

  8. Stress analysis of the tibial plateau according to the difference of blade path entry in opening wedge high tibial osteotomy

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Jun Woo; Xin, YuanZhu; Yang, Seok Jo [Chungnam National University, Daejeon (Korea, Republic of); Ji, Jong Hun; Panchal, Karnav; Kwon, Oh Soo [The Catholic University of Korea, Daejeon (Korea, Republic of)

    2015-03-15

    High tibial osteotomy (HTO) has been used to successfully treat patients with genu varus deformities that can improve mechanical function and condition in the knee joint. Clinical studies have reported that bow legs often occur with a concentrated load on the varus of the tibia. This study aimed to analyze and verify the clinical test data result by utilizing the three-dimensional (3D) static finite element method (FEM). The 3D model of lower extremities, which include the femur, tibia, meniscus, and knee articular cartilage, was created using the images from a computer tomography scan and magnetic resonance imaging. In this report, we compared changes in stress distribution and force reaction on the tibial plateau because of critical problems caused by unexpected changes in the tibial posterior-slope angle because of HTO. The results showed that the 5 .deg. wedge-angle virtual opening wedge HTO without and with the posterior-slope angle shows has a load concentration of approximately 60% and 45% in the medial region, respectively.

  9. EVALUATION OF FUNCTIONAL RESULTS OF MEDIAL OPENING WEDGE HIGH TIBIAL OSTEOTOMY FOR UNICOMPARTMENTAL OSTEOARTHRITIS VARUS KNEE

    Directory of Open Access Journals (Sweden)

    Shyam Sundar Bakki

    2017-01-01

    Full Text Available BACKGROUND Osteoarthritis commonly affects the medial compartment of knee giving rise to varus deformity in majority of cases. Significant varus deformity further aggravates the pathology due to medialisation of the weight bearing line osteotomy of the proximal tibia realigns this weight bearing axis, thereby relieving pressure on the damaged medial compartment. OWHTO is a promising option in this scenario because it is associated with high accuracy in correcting the deformity and less number of complications when compared to lateral closing wedge HTO or UKA. In this study, we evaluate the functional outcome of HTO in patients with unicompartmental osteoarthritis. MATERIALS AND METHODS This is a prospective study of patients who attended the orthopaedic outpatient clinic in Government Hospital, Kakinada, between August 2013 to August 2015. The patients were evaluated by clinical examination and weight bearing radiographs. The patients who were found to have unicompartmental osteoarthritis with knee pain not relieved by conservative management and who satisfy the inclusion criteria were selected. RESULTS Excellent results can be achieved by appropriate selection criteria and planning with long limb weight bearing radiographs. There is an excellent relief of pain, which can be achieved within first few months postoperatively, which is assessed by VAS score. The KSS- knee score is excellent in 35%, good in 40%, fair in 20% and poor in 5%. The KSS- function score is excellent in 30%, good in 45%, fair in 20% and poor in 5%. There is significant improvement in the range of movement of the knee joint postoperatively. CONCLUSION In this study, we conclude that medial OWHTO is the preferred modality for unicompartmental OA in those aged <60 years and in developing nations like India where squatting is an important function, it has major role as it can restore near normal knee function without disturbing anatomy.

  10. Radiographic and computed tomographic evaluation of bone union after medial opening wedge high tibial osteotomy with filling gap.

    Science.gov (United States)

    Kobayashi, Hideo; Akamatsu, Yasushi; Kumagai, Ken; Kusayama, Yoshihiro; Saito, Tomoyuki

    2017-10-01

    We evaluated bone union and remodelling in patients undergoing opening-wedge high tibial osteotomy (OWHTO) with bone gaps filled with beta-tricalcium phosphate. We examined the effectiveness of radiography and computed tomography (CT) for the evaluation of bone union and remodelling, and investigated whether lateral hinge fractures affected bone union. Sixty-six cases underwent OWHTO with a combination of a TomoFix plate and a bone substitute. Bone union and remodelling were assessed using the rating system for OWHTO at three and six months, postoperatively. Radiographic evaluation showed that bone union of the lateral hinge was 85% and 100% at three and six months, respectively. Based on CT evaluation, bone union of the lateral hinge and the flange was achieved in all cases at six months, and the bone union of the posterior cortex reached Zone 3 in 83% at six months. Based on radiographic evaluation, bone remodelling phases of bone substitute had progressed in each zone in six months compared with three months. Radiographic and CT analyses identified a Takeuchi type I hinge fracture in fourteen (21.2%) and five (7.6%) knees at two weeks postoperatively, respectively. There were no differences in bone union with and without the lateral hinge fracture. The use of CT enabled us to evaluate the bone union of the flange and the extent of the bone union of the posterior cortex. Plain radiographs are useful to evaluate bone union of the lateral hinge similar to CT analysis. The presence of a Takeuchi type I hinge fracture did not affect bone union. Copyright © 2017 Elsevier B.V. All rights reserved.

  11. Coronal subluxation of the proximal tibia relative to the distal femur after opening wedge high tibial osteotomy.

    Science.gov (United States)

    Akamatsu, Yasushi; Ohno, Satoshi; Kobayashi, Hideo; Kusayama, Yoshihiro; Kumagai, Ken; Saito, Tomoyuki

    2017-01-01

    The coronal subluxation of the proximal tibia relative to the distal femur is a common radiological finding in patients with knee osteoarthritis. The purpose was to evaluate whether the coronal subluxation was corrected after opening wedge high tibial osteotomy (OWHTO), and whether this subluxation was one cause of inconsistency between the actual and predicted alignments (correction loss). Fifty-one patients (55 knees) were treated with OWHTO. The change of location between the intersection points of the femoral and tibial axes on the tibial plateau (subluxation-C), the change of location between the lines through the most lateral points of the lateral femoral and tibial condyles (subluxation-L), and joint space angle (JSA) were compared in standing knee radiographs before and one year after OWHTO. The subluxation-C and subluxation-L were converted to a percentage of the tibial plateau width. The mean subluxation-C of 6.5% before OWHTO significantly increased to a mean subluxation-C of 7.3% one year after OWHTO. The mean subluxation-L of 6.3% and JSA of 4.5° before OWHTO significantly decreased to a subluxation-L of 1.8% and JSA of 3.3° one year after OWHTO. The change in subluxation-L correlated with the change in femorotibial angle and correction loss (r=0.634, P<0.001 and r=0.463, P<0.001, respectively). The proximal tibia shifted medially relative to the distal femur after OWHTO. This medial shift correlated with the correction loss. The coronal subluxation might be one cause of correction loss. Copyright © 2016 Elsevier B.V. All rights reserved.

  12. Studying the effect of medial open wedge high tibial osteotomy on the posterior slope of tibia among patients with Genu varum

    Directory of Open Access Journals (Sweden)

    Seyyed Raza Sharifzadeh

    2017-09-01

    Full Text Available Background A slight change in the posterior slope of tibia results in complications such as limited movement of knee joint and higher risks of Osteoarthritis. Aims The present research seeks to study levels of tibia’s posterior slope change and limited movement of knee joint and knee stability following medial open wedge osteotomy used to treat patients with genu varum. Methods The present research is a clinical trial conducted in the form of a before and after study on patients with genu varum resorting to Imam Reza (PBUH, Khanevade, and Fajr hospitals from 2009 to 2012. As many as 40 knees (32 patients were studied and the posterior slope of tibia before and after medial open wedge high tibial osteotomy was measured by someone totally unaware of the research using true lateral radiography. Movement limitation and stability of the knee was measured before and after the operation using scope of motion and Lachman and Drawer test. Paired sample test was used in this research and SPSS was used to analyse the data. Results The average posterior slope of tibia before the operation was 9.912, while this value changed to 11.625 after the operation signifying a significant increase. In terms of limited knee joint movement, 7 patients were diagnosed with grade 5 Extension LAG after operation, while the remaining 33 patients had a normal motion range (Extension LAG=0. Conclusion Medial open wedge osteotomy above tibia can help increase the posterior slope of tibia.

  13. Effect of Computer Navigation on Accuracy and Reliability of Limb Alignment Correction following Open-Wedge High Tibial Osteotomy: A Meta-Analysis

    Directory of Open Access Journals (Sweden)

    Seung-Beom Han

    2017-01-01

    Full Text Available Background. It is unclear whether computer navigation can improve the accuracy and reliability of targeted lower limb alignment correction following open-wedge high tibial osteotomy (HTO. This meta-analysis was designed to compare the accuracy and reliability of limb alignment correction between computer navigated and conventional open-wedge HTOs. Methods. Studies that compared postoperative coronal alignment, including mechanical axis (MA and weight bearing line (WBL ratio, outliers of alignment correction, and change in tibial posterior slope, following open-wedge HTO performed using computer navigated and conventional methods were included. Results. Ten studies were included in the meta-analysis. The MA (0.93°; 95% confidence interval [CI]: 0.45–1.41°; P<0.001 and WBL ratio (1.5%; 95% CI: 0.03–2.98%; P=0.048 were significantly greater for computer navigated HTO than for conventional HTO. Outliers of alignment correction after surgery were significantly lower in patients who underwent computer navigated HTO than in those who underwent conventional HTO (odds ratio: 0.25; 95% CI: 0.08–0.79; P=0.02. Changes in posterior tibial slope from before to after surgery, however, were similar for the two approaches. Conclusion. Computer navigated HTO resulted in slightly more valgus postoperative alignment and effectively reduced outliers of alignment correction but had no effect on change in posterior tibial slope when compared with conventional HTO.

  14. Survivorship of medial opening wedge high tibial osteotomy in the elderly: two to ten years of follow up.

    Science.gov (United States)

    Ruangsomboon, Pakpoom; Chareancholvanich, Keerati; Harnroongroj, Thos; Pornrattanamaneewong, Chaturong

    2017-10-01

    Medial opening wedge high tibial osteotomy (MOWHTO) is a well-accepted procedure, which has been widely used for pain relief and varus deformity correction in the osteoarthritic (OA) knee, especially in the young patient. However, in the elderly patient, the efficacy of this procedure is still unknown. Therefore, this study aims to evaluate the survivorship of MOWHTO in elderly patients as the primary outcome. The secondary outcome is to evaluate the loss of correction angle that is the common complication after MOWTHO. A retrospective study of 50 elderly patients (≥ 60 years) was conducted to track survivorship of MOWHTO. All patients were diagnosed with varus OA knee and underwent MOWHTO at our institute. The patients who had previous knee surgery or incomplete data were excluded. Medical records and radiographs of eligible patients were reviewed for recruiting the data. Survivorship of MOWHTO was analyzed using Kaplan-Meier curves. The starting point was the time of operation and the end point was the time of subsequent TKA. The loss of correction angle was defined as the change of medial proximal tibial angle (MPTA) between three months and one year post-operatively. The mean age of patients was 66 ± 5.0 years. The majority of patients were female (74%). The mean correction angle was 10.6 ± 3.6 degrees. The union rate of osteotomy site was 100%. In survival analysis, the median follow-up time was 6.0 ± 3.0 years. Two patients required subsequent conversions to TKA. The survivorship of MOWHTO at four years was 95.5% (95%CI, 96.0 to 98.0). For radiographic assessment, the loss of correction angle was 1.0 ± 0.5 degrees at one year post-operatively. This study proved that MOWHTO in patient ≥60 years had good mid-term survivorship with acceptable complications. This procedure can be the alternative option for the treatment of varus OA knee in the elderly.

  15. Clinical and Radiological Results with Second-Look Arthroscopic Findings after Open Wedge High Tibial Osteotomy without Arthroscopic Procedures for Medial Meniscal Root Tears.

    Science.gov (United States)

    Lee, Hyun Il; Park, Dongjun; Cho, Jinho

    2018-03-01

    To identify the structural integrity of the healing site after medial open wedge high tibial osteotomy (MOWHTO) in patients with a posterior root tear of the medial meniscus (PRTMM) and chondral lesion by second-look arthroscopy and to determine the clinical and radiological findings. From August 2010 to June 2016, 52 consecutive patients underwent MOWHTO and arthroscopic examination without a chondral resurfacing procedure and meniscal treatment for PRTMM. Twenty-four patients were available for second-look arthroscopic evaluation. The mean follow-up period was 19.5 months (range, 5 to 46 months). Clinical evaluation was based on the Lysholm knee scores and Hospital for Special Surgery (HSS) scores. There were 5 lax healing, 6 scar tissue, 13 failed healing of PRTMM. Definite change of chondral lesion was not observed. The Kellgren-Lawrence grade did not improve according to the follow-up plain radiograph. The mean Lysholm score improved from 34.7 preoperatively to 77.1 at the last follow-up, and the mean HSS score significantly increased from 36.5 to 82.4. This study revealed a low rate of healing potency of PRTMM and chondral lesion after MOWHTO without any attempt for meniscal treatment or chondral resurfacing. The cartilage and healing status of PRTMM was not associated with improved clinical outcomes and radiological findings.

  16. Management of an Infected Nonunion of an Opening-Wedge High Tibial Osteotomy with 2-Stage Implantation of Rotating Hinge Knee Prosthesis

    Directory of Open Access Journals (Sweden)

    Sandrine Mariaux

    2018-01-01

    Full Text Available Introduction. High tibial osteotomy (HTO is a frequent and effective treatment for unicompartmental gonarthritis. Only a few articles are focused on the treatment of infected nonunion. Patient and Method. A 50-year-old obese patient was operated on by medial opening-wedge HTO. She developed a painful nonunion treated by hardware removal, allograft, and plate fixation. However, the nonunion persisted. 2 years later, cellulitis appeared with an abscess adjacent to the HTO plate. Despite surgical debridement and antibiotics, septic knee arthritis occurred. In a situation of infected nonunion and septic arthritis with chondrolysis, she was scheduled for a 2-stage total knee replacement (TKR. The infected tibial articular block was first resected and replaced by a cement spacer. After a short interval, the TKR was implanted. After 2 years, the patient walked pain-free with good knee function. Discussion. In the literature, different efficient treatments exist for infected nonunion after HTO, but comprehensive studies are missing for a consensus treatment. Current data are mostly based on case reports, since this pathology is quite rare. Conclusion. In a difficult situation of infected nonunion with septic knee arthritis, we performed a 2-stage knee prosthesis implantation. This led to an early mobilization and fast recovery.

  17. Relaxation of the MCL after an Open-Wedge High Tibial Osteotomy results in decreasing contact pressures of the knee over time

    NARCIS (Netherlands)

    van Egmond, N.; Hannink, G.; Janssen, D.; Vrancken, A.C.; Verdonschot, N.; van Kampen, A.

    2017-01-01

    Purpose: The objective of this study was to investigate the effect of a medial open-wedge osteotomy (OWO) and the release of the superficial medial collateral ligament (MCL) on the tibiofemoral cartilage pressure, the MCL tension and the valgus laxity of the knee. Methods: Seven fresh-frozen, human

  18. Relaxation of the MCL after an Open-Wedge High Tibial Osteotomy results in decreasing contact pressures of the knee over time

    NARCIS (Netherlands)

    Egmond, N. van; Hannink, G.J.; Janssen, D.W.; Vrancken, A.C.; Verdonschot, N.J.; Kampen, A. van

    2017-01-01

    PURPOSE: The objective of this study was to investigate the effect of a medial open-wedge osteotomy (OWO) and the release of the superficial medial collateral ligament (MCL) on the tibiofemoral cartilage pressure, the MCL tension and the valgus laxity of the knee. METHODS: Seven fresh-frozen, human

  19. Static and fatigue strength of a novel anatomically contoured implant compared to five current open-wedge high tibial osteotomy plates.

    Science.gov (United States)

    Diffo Kaze, Arnaud; Maas, Stefan; Belsey, James; Hoffmann, Alexander; Pape, Dietrich

    2017-12-08

    The purpose of the present study was to compare the mechanical static and fatigue strength of the size 2 osteotomy plate "Activmotion" with the following five other common implants for the treatment of medial knee joint osteoarthritis: the TomoFix small stature, the TomoFix standard, the Contour Lock, the iBalance and the second generation PEEKPower. Six fourth-generation tibial bone composites underwent a medial open-wedge high tibial osteotomy (HTO), according to standard techniques, using size 2 Activmotion osteotomy plates. All bone-implant constructs were subjected to static compression load to failure and load-controlled cyclic fatigue failure testing, according to a previously defined testing protocol. The mechanical stability was investigated by considering different criteria and parameters: maximum forces, the maximum number of loading cycles, stiffness, the permanent plastic deformation of the specimens during the cyclic fatigue tests, and the maximum displacement range in the hysteresis loops of the cyclic loading responses. In each test, all bone-implant constructs with the size 2 Activmotion plate failed with a fracture of the lateral cortex, like with the other five previously tested implants. For the static compression tests the failure occurred in each tested implant above the physiological loading of slow walking (> 2400 N). The load at failure for the Activmotion group was the highest (8200 N). In terms of maximum load and number of cycles performed prior to failure, the size 2 Activmotion plate showed higher results than all the other tested implants except the ContourLock plate. The iBalance implant offered the highest stiffness (3.1 kN/mm) for static loading on the lateral side, while the size 2 Activmotion showed the highest stiffness (4.8 kN/mm) in cyclic loading. Overall, regarding all of the analysed strength parameters, the size 2 Activmotion plate provided equivalent or higher mechanical stability compared to the previously tested

  20. Ten-Year Results of Medial Open-Wedge High Tibial Osteotomy and Chondral Resurfacing in Severe Medial Osteoarthritis and Varus Malalignment.

    Science.gov (United States)

    Schuster, Philipp; Geßlein, Markus; Schlumberger, Michael; Mayer, Philipp; Mayr, Raul; Oremek, Damian; Frank, Sebastian; Schulz-Jahrsdörfer, Martin; Richter, Jörg

    2018-03-01

    High tibial osteotomy (HTO) is a widely used treatment option for medial osteoarthritis and varus malalignment, especially in young patients with early osteoarthritis. Limited outcome data are available for this procedure in severe osteoarthritis, and no long-term data are available using newer implants. To determine survivorship and functional results of medial open-wedge HTO combined with a chondral resurfacing (CR) procedure (abrasion plus microfracture) in severe medial osteoarthritis (Kellgren-Lawrence grade 3 and 4) and varus malalignment. Furthermore, factors that potentially influence the outcome were analyzed. Case series; Level of evidence, 4. From September 2005 to December 2008, all cases of HTO (fixation with an angular-stable internal fixator) combined with CR were prospectively surveyed with regard to survival (Kaplan-Meier-method, not requiring arthroplasty) and functional outcome (subjective International Knee Documentation Committee [IKDC] score). Cartilage regeneration at the time of hardware removal, tibial bone varus angle (TBVA), pre- and postoperative mechanical medial proximal tibial angle (MPTA), and postoperative alignment were analyzed with regard to the result. Seventy-nine knees were included (73 patients; mean age 50.9 ± 7.6 years). The follow-up rate was 90% at 10.0 ± 1.2 years (range, 8.3-12.1 years). Pre- and postoperative mechanical tibiofemoral axis were 9.6° ± 3.0° of varus and 0.6° ± 2.7° of valgus, respectively. Survival rate was 81.7% (95% CI, 72.5%-90.9%) at 10 years. Subjective IKDC score significantly improved from 44 ± 11 preoperatively to 70 ± 13 at one, 66 ± 15 at three, 66 ± 15 at five, and 65 ± 17 at ten years ( P 95°) with inferior functional outcome at final follow-up, respectively. Even in cases of severe medial osteoarthritis and varus malalignment, HTO in combination with a CR procedure is a good to excellent treatment option. The role of the CR procedure remains unclear. Although good results are

  1. Opening-wedge high tibial osteotomy without bone grafting in severe varus osteoarthritic knee. Rate and risk factors of non-union in 41 cases.

    Science.gov (United States)

    Siboni, R; Beaufils, P; Boisrenoult, P; Steltzlen, C; Pujol, N

    2018-03-16

    Using locking plates in opening-wedge high tibial osteotomy (OWHTO) via a medial opening theoretically allows early weight-bearing without need for bone or bone-substitute grafting. It incurs a risk of non-consolidation in case of large correction (> 10°), although rates and risk factors of non-union are not known. The present retrospective study compared OWHTO with correction 10°, with a view to determining: 1) complications rates (non-union) according to degree of correction, and 2) risk factors for such complications. OWHTO with correction greater than 10° without graft shows normal consolidation and allows early weight-bearing. Forty-one patients treated by OWHTO for medial osteoarthritis of the knee between January 2101 and November 2015 were included in a retrospective study. HKA angle was assessed by long-leg axis radiographs, preoperatively and at 3 months. Clinical and radiological follow-up at 6 weeks, 3 months and 6 months assessed consolidation in terms of >40% filling of the osteotomy site. Partial (contact) weight-bearing was allowed from the first postoperative day, with full weight-bearing at 6 weeks. Mean patient age was 59 ± 5 years. Mean body-mass index (BMI) was 30.3 ± 5.2; 17 patients (41.5%) had BMI >30. Mean initial HKA angle was 173.5° ± 3° (range, 167° - 178°) and mean correction was 10.7°± 2.7° (range, 5° - 15°). There were 27 corrections of 10° or more, and 14 less than 10°. At 3 months, mean HKA was 182.9° ± 2.5° (range, 178° - 187°). Twelve cases showed lateral tibial cortex fracture after opening. Thirty-six patients (87.8%) showed consolidation, at a mean 5 ± 3 months. Five patients showed osteotomy site non-union; in all these cases, the lateral cortex was broken initially (p=0.003); all had BMI >30 (mean, 37.2± 3.8; p 30 (OR=1.18; 95% CI, (1.03-1.41)) and correction ≥10° (OR=10.50; 95% CI, (2.49-53.86)) were associated with delayed consolidation. On multivariate analysis, only degree of osteotomy was

  2. Mechanism of bone incorporation of beta-TCP bone substitute in open wedge tibial osteotomy in patients.

    NARCIS (Netherlands)

    Gaasbeek, R.D.A.; Toonen, H.G.; Heerwaarden, R.J. van; Buma, P.

    2005-01-01

    A histological study was performed of bone biopsies from 16 patients (17 biopsies) treated with open wedge high tibial osteotomies for medial knee osteoarthritis. The open wedge osteotomies were filled with a wedge of osteoconductive beta tricalcium phosphate (beta-TCP) ceramic bone replacement. At

  3. Relaxation of the MCL after an Open-Wedge High Tibial Osteotomy results in decreasing contact pressures of the knee over time.

    Science.gov (United States)

    van Egmond, N; Hannink, G; Janssen, D; Vrancken, A C; Verdonschot, N; van Kampen, A

    2017-03-01

    The objective of this study was to investigate the effect of a medial open-wedge osteotomy (OWO) and the release of the superficial medial collateral ligament (MCL) on the tibiofemoral cartilage pressure, the MCL tension and the valgus laxity of the knee. Seven fresh-frozen, human cadaveric knees were used. Medial and lateral mean contact pressure (CP), peak contact pressure (peakCP), and contact area (CA) were measured using a pressure-sensitive film (I-Scan; Tekscan, Boston, MA). The MCL tension was measured using a custom-made device. These measurements were continuously recorded for 5 min after an OWO of 10°. After the osteotomy, the valgus laxity was measured with a handheld Newtonmeter. For one knee, the measurements were continued for 24 h. At the end, a complete release of the superficial MCL was performed and the measurements were repeated at 10°. There was relaxation of the MCL after the osteotomy; the tension dropped in 5 min with 10.7% (mean difference 20.5 N (95% CI 16.1-24.9)), and in 24 h, the tension decreased by 24.2% (absolute difference 38.8 N) (one knee). After the osteotomy, the mean CP, peakCP and CA increased in the medial compartment (absolute difference 0.17 MPa (95% CI 0.14-0.20), 0.27 MPa (95% CI 0.24-0.30), 132.9mm 2 (95% CI 67.7-198.2), respectively), and decreased in the lateral compartment (absolute difference 0.02 MPa (95% CI 0.03 -0.01), 0.08 MPa (95% CI 0.11 - 0.04), 47.0 mm 2 (95% CI -105.8 to 11.8), respectively). Only after a release of the superficial MCL, the mean CP, peak CP and CA significantly decreased in the medial compartment (absolute difference 0.17, 0.27 MPa, 119.8 mm 2 , respectively), and increased in the lateral compartment (absolute difference 0.02, 0.11 MPa, 52.4 mm 2 , respectively). After the release of the superficial MCL, a mean increase of 7.9° [mean difference - 0.1° (95% CI -1.9 to 1.6)] of the valgus laxity was found. A release of the superficial MCL helps achieve the goal of

  4. Open-wedge osteotomy using an internal plate fixator in patients with medial-compartment gonarthritis and varus malalignment

    DEFF Research Database (Denmark)

    Niemeyer, Philipp; Schmal, Hagen; Hauschild, Oliver

    2010-01-01

    PURPOSE: Our purpose was to evaluate the 3-year clinical results of patients with medial-compartment osteoarthritis of the knee and varus malalignment who underwent open-wedge high tibial osteotomy (HTO) with an internal plate fixator (TomoFix; Synthes, Solothurn, Switzerland). Clinical results...... of patients reported discomfort related to the implant at some point during the follow-up period (40.6%). CONCLUSIONS: Open-wedge osteotomy by use of the TomoFix system leads to reliable 3-year results. Results do not depend on the severity of medial cartilage defects, whereas partial-thickness defects...

  5. [Distal femoral osteotomy using a lateral opening wedge technique].

    Science.gov (United States)

    Feucht, M J; Mehl, J; Forkel, P; Imhoff, A B; Hinterwimmer, S

    2017-08-01

    To shift the weight-bearing axis of the lower limb medially by opening a lateral-based metaphyseal osteotomy at the distal femur. Femoral-based valgus malalignment and symptomatic lateral unicompartimental osteoarthritis, lateral hyperpression syndrome, cartilage therapy of the lateral compartment, lateral meniscal replacement/transplantation, medial instability with valgus thrust, reconstruction of the medial collateral ligament, patellar instability and/or maltracking. Advanced cartilage damage (>grade 2) or subtotal meniscal loss of the medial compartment, age >65 years (relative), nicotine abuse, body mass index >30, flexion contracture >25°, corrections with a wedge base >10 mm in case of congenital deformities, inflammatory or septic arthritis, severe osteoporosis. Lateral approach to the distal femur; biplanar osteotomy (frontal + axial osteotomy), gradual opening of the osteotomy, osteotomy fixation with a locking plate. Free range of motion. Partial weight bearing with 20 kg for 2 weeks, followed by progressive weight bearing thereafter. Mean improvement of knee scores from 20-30 points and mean 10-year survival rate of 80% in patients with lateral unicompartimental osteoarthritis. Mean complication rate of 9%.

  6. Management of valgus extra-articular calcaneus fracture malunions with a lateral opening wedge osteotomy.

    Science.gov (United States)

    Aly, Tarek

    2011-01-01

    A total of 34 cases of symptomatic valgus deformity of the hindfoot secondary to a malunited extra-articular calcaneal fracture were corrected with laterally based open wedge calcaneal osteotomy. The pre- and postoperative radiographic parameters were compared, and a postoperative clinical evaluation was performed using the American Orthopedic Foot and Ankle Society ankle and hindfoot scoring system. The mean follow-up period was 56.2 (range 24.1 to 97) months. The most significant radiographic changes were improvement in the talonavicular coverage angle (mean 17.3°) on the anteroposterior view. The mean postoperative American Orthopedic Foot and Ankle Society hindfoot and ankle score was 90, with 23 excellent, 8 good, and 3 poor results. Laterally based opening wedge osteotomy of the calcaneus is effective in the management of a valgus heel resulting from malunited extra-articular calcaneal fractures. Lateral decompression of the peroneal tendons and the sural nerve was achieved indirectly through opening wedge lateral calcaneal osteotomy that shifted the weight-bearing axis laterally. Copyright © 2011 American College of Foot and Ankle Surgeons. Published by Elsevier Inc. All rights reserved.

  7. Open wedge metatarsal osteotomy versus crescentic osteotomy to correct severe hallux valgus deformity

    DEFF Research Database (Denmark)

    Wester, Jens Ulrik; Hamborg-Petersen, Ellen; Herold, Niels

    2016-01-01

    BACKGROUND: Different techniques of proximal osteotomies have been introduced to correct severe hallux valgus. The open wedge osteotomy is a newly introduced method for proximal osteotomy. The aim of this prospective randomized study was to compare the radiological and clinical results after...... operation for severe hallux valgus, comparing the open wedge osteotomy to the crescentic osteotomy which is our traditional treatment. METHODS: Forty-five patients with severe hallux valgus (hallux valgus angle >35̊, and intermetatarsal angle >15̊) were included in this study. The treatment was proximal...... and 12 months after the operation. RESULTS: In group 1 the hallux valgus angle decreased from 39.0̊ to 24.1̊ after 4 months and 27.9̊ after 12 months. In group 2 the angle decreased from 38.3̊ to 21.4̊ after 4 months and 27.0̊ after 12 months. The intermetatarsal angle in group 1 was 19.0̊ preoperatively...

  8. Minimally invasive opening wedge tibia outpatient osteotomy, using screw-to-plate locking technique and a calcium phosphate cement.

    Science.gov (United States)

    Schwartz, Claude

    2018-01-10

    Medial knee osteoarthritis on angular varus deformity of a lower limb is very common. Open-wedge high tibial osteotomy is a treatment of choice if cartilage is not excessively worn (Allback 1 or 2). The technique based on a plate fixation and the bone defect filled with calcium phosphate cement is thoroughly described. Data at 1, 3, 6 months and 1 year of a 19 cases continuous and prospective series are collected and analysed. Mean age at the time of operation was 55 years. The average preoperative varus deformity was 5° and corrected to an average postoperative valgus of 4° (range 3°-6°). Each control includes the collection of eventual complications, the measurement of health status (quality of life and functional scores) and antero-posterior and lateral X-rays. All osteotomies were considered healed at 6 weeks without any correction loss except one, probably result of a technical error. There was no difference in clinical and functional results between the group and the literature, but the final result occurred earlier in the treatment when the bone defect was filled with either calcium phosphate cement. Faster recovery involved no specific complication and enabled outpatient treatment in a majority of patients.

  9. Open wedge metatarsal osteotomy versus crescentic osteotomy to correct severe hallux valgus deformity - A prospective comparative study.

    Science.gov (United States)

    Wester, Jens Ulrik; Hamborg-Petersen, Ellen; Herold, Niels; Hansen, Palle Bo; Froekjaer, Johnny

    2016-03-01

    Different techniques of proximal osteotomies have been introduced to correct severe hallux valgus. The open wedge osteotomy is a newly introduced method for proximal osteotomy. The aim of this prospective randomized study was to compare the radiological and clinical results after operation for severe hallux valgus, comparing the open wedge osteotomy to the crescentic osteotomy which is our traditional treatment. Forty-five patients with severe hallux valgus (hallux valgus angle >35̊, and intermetatarsal angle >15̊) were included in this study. The treatment was proximal open wedge osteotomy and fixation with plate (Hemax), group 1, or operation with proximal crescentic osteotomy and fixation with a 3mm cannulated screw, group 2. The mean age was 52 years (19-71). Forty-one females and four males were included. Clinical and radiological follow-ups were performed 4 and 12 months after the operation. In group 1 the hallux valgus angle decreased from 39.0̊ to 24.1̊ after 4 months and 27.9̊ after 12 months. In group 2 the angle decreased from 38.3̊ to 21.4̊ after 4 months and 27.0̊ after 12 months. The intermetatarsal angle in group 1 was 19.0̊ preoperatively, 11.6̊ after 4 months and 12.6̊ after 12 months. In group 2 the mean intermetatarsal angle was 18.9̊ preoperatively, 12.0̊ after 4 months and 12.6̊ after 12 months. The AOFAS score improved from 59.3 to 81.5 in group 1 and from 61.8 to 84.8 in group 2 respectively measured 12 months postoperatively. The relative length of the 1 metatarsal compared to 2 metatarsal bone was 0.88 and 0.87 preoperatively and 0.88 and 0.86 for group 1 and 2 respectively measured after 12 months. Crescentic osteotomy and open wedge osteotomy improve AOFAS score and VAS scores on patients operated with severe hallux valgus. No significant difference was found in the two groups looking at the postoperative improvement of HVA and IMA measured 4 and 12 months postoperatively. The postoperative VAS score and AOFAS score were

  10. Upright Biplanar Slot Scanning in Pediatric Orthopedics: Applications, Advantages, and Artifacts.

    Science.gov (United States)

    Hull, Nathan C; Binkovitz, Larry A; Schueler, Beth A; Kolbe, Amy B; Larson, A Noelle

    2015-07-01

    Digital slot scanning is a relatively new technology that has been used for imaging of pediatric orthopedic conditions such as scoliosis and leg-length discrepancies. This article will review the clinical applications, advantages, and unique artifacts of this new technology. Upright biplanar slot scanners acquire high-resolution radiographs simultaneously in two orthogonal planes with reduced radiation dose. Other advantages include a more physiologic weightbearing imaging position, improved Cobb angle measurements, and 3D modeling.

  11. Three-dimensional hindfoot alignment measurements based on biplanar radiographs: comparison with standard radiographic measurements

    Energy Technology Data Exchange (ETDEWEB)

    Sutter, Reto; Pfirrmann, Christian W.A.; Buck, Florian M. [University Hospital Balgrist, Department of Radiology, Zurich (Switzerland); University of Zurich, Zurich (Switzerland); Espinosa, Norman [University Hospital Balgrist, Department of Orthopedic Surgery, Zurich (Switzerland); University of Zurich, Zurich (Switzerland)

    2013-04-15

    To establish a hindfoot alignment measurement technique based on low-dose biplanar radiographs and compare with hindfoot alignment measurements on long axial view radiographs, which is the current reference standard. Long axial view radiographs and low-dose biplanar radiographs of a phantom consisting of a human foot skeleton embedded in acrylic glass (phantom A) and a plastic model of a human foot in three different hindfoot positions (phantoms B1-B3) were imaged in different foot positions (20 internal to 20 external rotation). Two independent readers measured hindfoot alignment on long axial view radiographs and performed 3D hindfoot alignment measurements based on biplanar radiographs on two different occasions. Time for three-dimensional (3D) measurements was determined. Intraclass correlation coefficients (ICC) were calculated. Hindfoot alignment measurements on long axial view radiographs were characterized by a large positional variation, with a range of 14 /13 valgus to 22 /27 varus (reader 1/2 for phantom A), whereas the range of 3D hindfoot alignment measurements was 7.3 /6.0 to 9.0 /10.5 varus (reader 1/2 for phantom A), with a mean and standard deviation of 8.1 {+-} 0.6/8.7 {+-} 1.4 respectively. Interobserver agreement was high (ICC = 0.926 for phantom A, and ICC = 0.886 for phantoms B1-B3), and agreement between different readouts was high (ICC = 0.895-0.995 for reader 1, and ICC = 0.987-0.994 for reader 2) for 3D measurements. Mean duration of 3D measurements was 84 {+-} 15/113 {+-} 15 s for reader 1/2. Three-dimensional hindfoot alignment measurements based on biplanar radiographs were independent of foot positioning during image acquisition and reader independent. In this phantom study, the 3D measurements were substantially more precise than the standard radiographic measurements. (orig.)

  12. First Metatarsal Proximal Opening Wedge Osteotomy for Correction of Hallux Valgus Deformity: Comparison of Straight versus Oblique Osteotomy

    Science.gov (United States)

    Han, Seung Hwan; Park, Eui Hyun; Jo, Joon; Koh, Yong Gon; Lee, Jin Woo; Choi, Woo Jin

    2015-01-01

    Purpose The aim of this study was to compare clinical and radiographic outcomes of proximal opening wedge osteotomy using a straight versus oblique osteotomy. Materials and Methods We retrospectively reviewed 104 consecutive first metatarsal proximal opening wedge osteotomies performed in 95 patients with hallux valgus deformity. Twenty-six feet were treated using straight metatarsal osteotomy (group A), whereas 78 feet were treated using oblique metatarsal osteotomy (group B). The hallux valgus angle (HVA), intermetatarsal angle (IMA), distal metatarsal articular angle, and distance from the first to the second metatarsal (distance) were measured for radiographic evaluation, whereas the American Orthopaedic Foot and Ankle Society (AOFAS) forefoot score was used for clinical evaluation. Results Significant corrections in the HVA, IMA, and distance from the first to the second metatarsal were obtained in both groups at the last follow-up (p<0.001). There was no difference in the mean IMA correction between the 2 groups (6.1±2.7° in group A and 6.0±2.1° in group B). However, a greater correction in the HVA and distance from the first to the second metatarsal were found in group B (HVA, 13.2±8.2°; distance, 25.1±0.2 mm) compared to group A (HVA, 20.9±7.7°; distance, 28.1±0.3 mm; p<0.001). AOFAS scores were improved in both groups. However, group B demonstrated a greater improvement relative to group A (p=0.005). Conclusion Compared with a straight first metatarsal osteotomy, an oblique first metatarsal osteotomy yielded better clinical and radiological outcomes. PMID:25837181

  13. First Metatarsophalangeal Contact Properties Following Proximal Opening Wedge and Scarf Osteotomies for Hallux Valgus Correction: A Biomechanical Study.

    Science.gov (United States)

    Kia, Cameron; Yoshida, Ryu; Cote, Mark; DiVenere, Jessica; Geaney, Lauren E

    2017-04-01

    Proximal opening wedge osteotomy (POWO) is an established procedure for moderate to severe hallux valgus. A common concern of this procedure is that it results in lengthening of the first metatarsal, which could cause increased intra-articular pressure of the first metatarsophalangeal joint (MTP) and may ultimately lead to arthritis because of these altered mechanics. The purpose of this study was to use a cadaveric model to compare intra-articular pressures and articulating contact properties of the MTP joint following either scarf osteotomy or POWO. Fresh-frozen cadaveric below-knee specimens with pre-existing hallux valgus (n = 12) and specimens without hallux valgus (n = 6, control group) were used. The hallux valgus specimens were stratified into 2 groups (n = 6 each): POWO or scarf osteotomy. The groups were matched based on the degree of deformity. Peak intra-articular pressure, force, and area were measured in all normal, preoperative, and postoperative specimens with a simulated weightbearing model. These measurements were made with a pressure transducer placed within the first MTP joint. Postoperatively POWO group had slightly higher contact forces and pressures compared to the scarf group and lower contact forces and pressures than those of the normal group but were not statistically significant ( P > .05). Normal specimens had higher intra-articular force, pressure, and area than postoperative specimens but the difference was not found to be significant. First metatarsal lengthening was found in both the scarf and POWO specimens; however, neither increase was found to be significant ( P > .05). The results from this study show that after operative correction, contact properties of the fist MTP joint among normal, POWO, and scarf osteotomy groups revealed no significant differences. First MTP joints in those with hallux valgus had significantly lower contact force and pressure compared to those without hallux valgus. With little long-term outcomes of

  14. Complicações da osteotomia em cunha de abertura medial do joelho: estudo retrospectivo Complications following medial opening wedge osteotomy of the knee: retrospective study

    Directory of Open Access Journals (Sweden)

    Wilson Alves de Mello Junior

    2011-01-01

    Full Text Available OBJETIVO: Realizar um levantamento retrospectivo das complicações mais frequentes da osteotomia tibial alta (OTA em cunha de abertura medial. Esse procedimento vem a cada vez ganhando mais espaço no tratamento da artrose do joelho como uma das opções para pacientes jovens e ativos. Apesar dos resultados satisfatórios e seus benefícios, não é procedimento isento de complicações. MÉTODOS: Foram avaliados, retrospectivamente, todos os pacientes submetidos à OTA supratuberositária medial de cunha de abertura e fixados com placa do tipo Puddu, realizadas no período de 1 de outubro de 1987 a 30 de outubro de 2008, no Hospital e Maternidade Celso Pierro da Pontifícia Universidade Católica de Campinas (PUC-Campinas e no Instituto Wilson Mello em Campinas. Foram excluídos pacientes com menos de 12 meses de seguimento, com prontuários incompletos, e os que tinham osteotomias bilaterais. RESULTADOS: Dos 67 casos avaliados, 55 eram do sexo masculino e 12 do feminino, com média de idade de 49,5 anos. O tamanho médio da cunha foi de 10,15mm e as complicações mais frequentes foram dor moderada e grave (13,04%, seguida de rigidez (6,52%, quebra de material (4,4%, fratura da cortical lateral intraoperatória (4,4% e infecção (4,4%. CONCLUSÃO: Foi observado aumento de probabilidade de complicações quando há retardo na consolidação da osteotomia (p OBJECTIVE: To retrospectively survey the most frequent complications from medial opening wedge high-tibial osteotomy. This procedure is becoming increasingly important in treating knee arthrosis, as one of the options for young and active patients. Despite satisfactory results and its benefits, it is not a complication -free procedure. METHODS: All cases of medial opening wedge high-tibial osteotomy above the tibial tubercle with fixation using a Puddu plate that were performed at the Celso Pierro Hospital and Maternity Hospital, Pontifical Catholic University of Campinas (PUC -Campinas

  15. Correction of moderate to severe hallux valgus with combined proximal opening wedge and distal chevron osteotomies: a reliable technique.

    Science.gov (United States)

    Jeyaseelan, L; Chandrashekar, S; Mulligan, A; Bosman, H A; Watson, A J S

    2016-09-01

    The mainstay of surgical correction of hallux valgus is first metatarsal osteotomy, either proximally or distally. We present a technique of combining a distal chevron osteotomy with a proximal opening wedge osteotomy, for the correction of moderate to severe hallux valgus. We reviewed 45 patients (49 feet) who had undergone double osteotomy. Outcome was assessed using the American Orthopaedic Foot and Ankle Society (AOFAS) and the Short Form (SF) -36 Health Survey scores. Radiological measurements were undertaken to assess the correction. The mean age of the patients was 60.8 years (44.2 to 75.3). The mean follow-up was 35.4 months (24 to 51). The mean AOFAS score improved from 54.7 to 92.3 (p hallux valgus and intermetatarsal angles were improved from 41.6(o) to 12.8(o) (p < 0.001) and from 22.1(o) to 7.1(o), respectively (p < 0.001). The mean distal metatarsal articular angle improved from 23(o) to 9.7(o). The mean sesamoid position, as described by Hardy and Clapham, improved from 6.8 to 3.5. The mean length of the first metatarsal was unchanged. The overall rate of complications was 4.1% (two patients). These results suggest that a double osteotomy of the first metatarsal is a reliable, safe technique which, when compared with other metatarsal osteotomies, provides strong angular correction and excellent outcomes with a low rate of complications. Cite this article: Bone Joint J 2016;98-B:1202-7. ©2016 The British Editorial Society of Bone & Joint Surgery.

  16. Robust femur condyle disambiguation on biplanar X-rays.

    Science.gov (United States)

    Serrurier, Antoine; Quijano, Sergio; Nizard, Remy; Skalli, Wafa

    2012-12-01

    Three-dimensional (3D) reconstruction of the skeleton from biplanar X-rays relies on scarce information digitalised by an operator on both frontal and lateral radiographs. In clinical routine, difficulties occur for non-skilled operators to discriminate the medial from the lateral femur condyle on the lateral view. Our study proposes an algorithm able to detect automatically a possible inversion of the two condyles by the operator at an early stage of the reconstruction process. It relies on the computation of two 3D femur surfaces, one directly from the operator digitalisation and the other from the same digitalisation with medial and lateral condyles automatically swapped. Pairs of virtual biplanar X-rays are computed for both reconstructions and the closest pair to the original X-rays is selected on the basis of similarity measures, pointing the correct 3D surface. The algorithm shows a success rate higher than 85% for both asymptomatic and pathological femurs whatever the initial condyle digitalisation of the operator, bringing automatically non-skilled operators acting in clinical routine to the level of skilled operators. This study validates moreover the proof-of-concept of automatic shape adjustments of a 3D surface on the basis of similarity measures in the process of 3D reconstruction from biplanar X-rays. Copyright © 2012 IPEM. Published by Elsevier Ltd. All rights reserved.

  17. Optimization reconstruction method of object profile using flexible laser plane and bi-planar references.

    Science.gov (United States)

    Xu, Guan; Yuan, Jing; Li, Xiaotao; Su, Jian

    2018-01-24

    An optimization method to reconstruct the object profile is performed by using a flexible laser plane and bi-planar references. The bi-planar references are considered as flexible benchmarks to realize the transforms among two world coordinate systems on the bi-planar references, the camera coordinate system and the image coordinate system. The laser plane is confirmed by the intersection points between the bi-planar references and laser plane. The 3D camera coordinates of the intersection points between the laser plane and a measured object are initially reconstructed by the image coordinates of the intersection points, the intrinsic parameter matrix and the laser plane. Meanwhile, an optimization function is designed by the parameterized differences of the reconstruction distances with the help of a target with eight markers, and the parameterized reprojection errors of feature points on the bi-planar references. The reconstruction method with the bi-planar references is evaluated by the difference comparisons between true distances and standard distances. The mean of the reconstruction errors of the initial method is 1.01 mm. Moreover, the mean of the reconstruction errors of the optimization method is 0.93 mm. Therefore, the optimization method with the bi-planar references has great application prospects in the profile reconstruction.

  18. Comparative Study Between Pedicle Subtraction Osteotomy (PSO) and Closing-Opening Wedge Osteotomy (Fish-Mouth PSO) for Sagittal Plane Deformity Correction.

    Science.gov (United States)

    Park, Jong-Hwa; Hyun, Seung-Jae; Kim, Ki-Jeong; Jahng, Tae-Ahn

    2017-08-01

    A retrospective study. To evaluate the safety and efficacy of closing-opening wedge osteotomy (fish-mouth pedicle subtraction osteotomy [PSO]), for sagittal plane deformity correction and to compare the radiographical outcomes for patients undergoing conventional- and fish-mouth PSO. The closing-opening wedge osteotomy has been developed to achieve a large magnitude of correction at a single level for patients with severe fixed sagittal imbalance. We retrospectively reviewed the medical records and the radiographs of patients who underwent PSO by a single surgeon between June 2012 and December 2015. Forty patients were included and were divided into 2 groups according to surgical technique (fish-mouth- vs. conventional PSO group). Radiographical measurements included pelvic incidence, thoracic kyphosis, lumbar lordosis, global kyphosis (GK), sagittal vertical axis, osteotomized vertebra angle (OVA), and the height of the osteotomized vertebra (HOV). The preoperative, immediate postoperative, ultimate follow-up and correction of thoracic kyphosis, lumbar lordosis, thoracolumbar junction, and sagittal vertical axis did not show significant differences between the groups. Preoperative GK and OVA were significantly larger in fish-mouth group (GK: 47.1° ± 28.8° vs. 23.7° ± 16.0°, P PSO group (GK: 48.8° ± 24.5° vs. 34.8° ± 17.4°, P PSO group (2.3 vs. 1.7 cm, P PSO and PSO group, respectively. Fish-mouth PSO can provide a larger magnitude of correction compared to classic PSO without compromising spinal cord function for fixed sagittal plane deformity. 3.

  19. Error Analysis and Experimental Study of a Bi-Planar Parallel Mechanism in a Pedicle Screw Robot System.

    Science.gov (United States)

    Duan, Qingjuan; Du, Zhijiang; Yu, Hongjian; Wang, Yongfeng; Dong, Wei

    2016-11-30

    Due to the urgent need for high precision surgical equipment for minimally invasive spinal surgery, a novel robot-assistant system was developed for the accurate placement of pedicle screws in lumbar spinal surgeries. The structure of the robot was based on a macro-micro mechanism, which includes a serial mechanism (macro part) and a bi-planar 5R parallel mechanism (micro part). The macro part was used to achieve a large workspace, while the micro part was used to obtain high stiffness and accuracy. Based on the transfer function of dimension errors, the factors affecting the accuracy of the end effectors were analyzed. Then the manufacturing errors and joint angle error on the position-stance of the end effectors were investigated. Eventually, the mechanism of the strain energy produced by the deformation of linkage via forced assembly and displacements of the output point were calculated. The amount of the transfer errors was quantitatively analyzed by the simulation. Experimental tests show that the error of the bi-planar 5R mechanism can be controlled no more than 1 mm for translation and 1° for rotation, which satisfies the required absolute position accuracy of the robot.

  20. Minimally Invasive Cochlear Implantation Assisted by Bi-planar Device: An Exploratory Feasibility Study in vitro

    Directory of Open Access Journals (Sweden)

    Jia Ke

    2016-01-01

    Conclusions: This exploratory study demonstrated the safety of the newly developed image-guided minimally invasive cochlear implantation assisted by the bi-planar device and established the operational procedures. Further, more in vitro experiments are needed to improve the system operation and its safety.

  1. Effect and safety of early weight-bearing on the outcome after open-wedge high tibial osteotomy: a systematic review and meta-analysis.

    Science.gov (United States)

    Lee, O-Sung; Ahn, Soyeon; Lee, Yong Seuk

    2017-07-01

    The purpose of this systematic review and meta-analysis was to evaluate the effectiveness and safety of early weight-bearing by comparing clinical and radiological outcomes between early and traditional delayed weight-bearing after OWHTO. A rigorous and systematic approach was used. The methodological quality was also assessed. Results that are possible to be compared in two or more than two articles were presented as forest plots. A 95% confidence interval was calculated for each effect size, and we calculated the I 2 statistic, which presents the percentage of total variation attributable to the heterogeneity among studies. The random-effects model was used to calculate the effect size. Six articles were included in the final analysis. All case groups were composed of early full weight-bearing within 2 weeks. All control groups were composed of late full weight-bearing between 6 weeks and 2 months. Pooled analysis was possible for the improvement in Lysholm score, but there was no statistically significant difference shown between groups. Other clinical results were also similar between groups. Four studies reported mechanical femorotibial angle (mFTA) and this result showed no statistically significant difference between groups in the pooled analysis. Furthermore, early weight-bearing showed more favorable results in some radiologic results (osseointegration and patellar height) and complications (thrombophlebitis and recurrence). Our analysis supports that early full weight-bearing after OWHTO using a locking plate leads to improvement in outcomes and was comparable to the delayed weight-bearing in terms of clinical and radiological outcomes. On the contrary, early weight-bearing was more favorable with respect to some radiologic parameters and complications compared with delayed weight-bearing.

  2. 3D Modeling of Lower Extremities With Biplanar Radiographs: Reliability of Measures on Subsequent Examinations.

    Science.gov (United States)

    Westberry, David E; Carpenter, Ashley M

    2017-08-02

    Biplanar radiography with 3-dimensional (3D) modeling (EOS) provides a comprehensive assessment of lower limb alignment in an upright weight-bearing position with less radiation than conventional radiography. A study was performed to assess the consistency and reliability of 2 lower extremity 3D biplanar radiograph models created at least 1 year apart in a pediatric population. All patients who had 2 lower extremity radiographic evaluations with EOS performed at visits a minimum of 1 year apart were reviewed. Digital radiographs, of lower extremities in both frontal and sagittal planes, were acquired simultaneously, using the EOS system. The 3D reconstruction of the images was achieved utilizing the SterEOS software. Pelvic position, femoral and tibial anatomy, and the torsional profile were evaluated and compared using t tests. In total, 53 patients with a mean age of 11.7 years (range, 6.1 to 18.9 y) met inclusion criteria. When comparing 3D models between visits, minimal differences were noted in proximal femoral anatomy and pelvic alignment (pelvic incidence, sacral slope, sagittal tilt, neck shaft angle). Expected differences in femoral and tibial length corresponded with normal longitudinal growth between visits. Sagittal plane knee position varied widely between examinations. Femoral and/or tibial rotational osteotomies were performed in 37% of extremities between examinations. After femoral derotational osteotomy, a significant difference in femoral anteversion was appreciated when comparing preoperative and postoperative 3D models. However, this difference was less than the expected difference based on the anatomic correction achieved intraoperatively. No differences were noted in tibial torsion measures after tibial derotational osteotomy. The 3D modeling based on biplanar radiographs provides consistent and reliable measures of pelvic and hip joint anatomy of the lower extremity. Patient positioning may influence the reproducibility of knee alignment

  3. Low-dose biplanar skeletal survey versus digital skeletal survey in multiple myeloma

    International Nuclear Information System (INIS)

    Boutry, Nathalie; Dutouquet, Bastien; Cotten, Anne; Leleu, Xavier; Vieillard, Marie-Helene; Duhamel, Alain

    2013-01-01

    To evaluate the low-dose biplanar (LDB) skeletal survey (SS) for the assessment of focal bone involvement in patients with multiple myeloma (MM) as compared with digital SS and to compare the two techniques in terms of image quality, patient comfort and radiation exposure. Fifty-six consecutive patients with newly diagnosed or first relapsed MM underwent LDB and digital SS on the same day. These were assessed by two radiologists for the detection of focal bone lesions. In the case of discordance, whole-body MR imaging was performed. Image quality, patient comfort and radiation dose were also assessed. Fifty-six patients (M:30, F:26, mean age, 62 years) with newly diagnosed (n = 21) or first relapse MM (n = 35) were enrolled. A total of 473 bone lesions in 46 patients (82 %) were detected. Out of that total, digital SS detected significantly more lesions than LDB SS (451 [95.35 %] versus 467 [98.73 %]), especially in osteopenic and obese patients. Overall patient satisfaction was greater with LDB SS (48.6 %) compared with digital SS (2.7 %). The radiation dose was significantly reduced (by a factor of 7.8) with the LDB X-ray device. Low-dose biplanar skeletal surveys cannot replace digital SS in all patients suffering from multiple myeloma. (orig.)

  4. Low-dose biplanar skeletal survey versus digital skeletal survey in multiple myeloma

    Energy Technology Data Exchange (ETDEWEB)

    Boutry, Nathalie [University Hospital of Jeanne de Flandre and University of Lille 2, Departments of Pediatric and Musculoskeletal Imaging, Lille (France); University Hospital of Jeanne de Flandre and University of Lille 2, Department of Pediatric Imaging, Lille (France); Hopital Jeanne de Flandre, Service de Radiopediatrie, Lille (France); Dutouquet, Bastien; Cotten, Anne [University Hospital of Roger Salengro and University of Lille 2, Department of Musculoskeletal Imaging, Lille (France); Leleu, Xavier [University Hospital of Claude Huriez and University of Lille 2, Clinical Hematology Department, Lille (France); Vieillard, Marie-Helene [University Hospital of Roger Salengro and University of Lille 2, Rheumatology Department, Lille (France); Duhamel, Alain [University of Lille 2, Department of Medical Statistics, Lille (France)

    2013-08-15

    To evaluate the low-dose biplanar (LDB) skeletal survey (SS) for the assessment of focal bone involvement in patients with multiple myeloma (MM) as compared with digital SS and to compare the two techniques in terms of image quality, patient comfort and radiation exposure. Fifty-six consecutive patients with newly diagnosed or first relapsed MM underwent LDB and digital SS on the same day. These were assessed by two radiologists for the detection of focal bone lesions. In the case of discordance, whole-body MR imaging was performed. Image quality, patient comfort and radiation dose were also assessed. Fifty-six patients (M:30, F:26, mean age, 62 years) with newly diagnosed (n = 21) or first relapse MM (n = 35) were enrolled. A total of 473 bone lesions in 46 patients (82 %) were detected. Out of that total, digital SS detected significantly more lesions than LDB SS (451 [95.35 %] versus 467 [98.73 %]), especially in osteopenic and obese patients. Overall patient satisfaction was greater with LDB SS (48.6 %) compared with digital SS (2.7 %). The radiation dose was significantly reduced (by a factor of 7.8) with the LDB X-ray device. Low-dose biplanar skeletal surveys cannot replace digital SS in all patients suffering from multiple myeloma. (orig.)

  5. A hybrid optimization method for biplanar transverse gradient coil design

    International Nuclear Information System (INIS)

    Qi Feng; Tang Xin; Jin Zhe; Jiang Zhongde; Shen Yifei; Meng Bin; Zu Donglin; Wang Weimin

    2007-01-01

    The optimization of transverse gradient coils is one of the fundamental problems in designing magnetic resonance imaging gradient systems. A new approach is presented in this paper to optimize the transverse gradient coils' performance. First, in the traditional spherical harmonic target field method, high order coefficients, which are commonly ignored, are used in the first stage of the optimization process to give better homogeneity. Then, some cosine terms are introduced into the series expansion of stream function. These new terms provide simulated annealing optimization with new freedoms. Comparison between the traditional method and the optimized method shows that the inhomogeneity in the region of interest can be reduced from 5.03% to 1.39%, the coil efficiency increased from 3.83 to 6.31 mT m -1 A -1 and the minimum distance of these discrete coils raised from 1.54 to 3.16 mm

  6. Benefits and unexpected artifacts of biplanar digital slot-scanning imaging in children.

    Science.gov (United States)

    Blumer, Steven L; Dinan, David; Grissom, Leslie E

    2014-07-01

    Biplanar digital slot-scanning allows for relatively low-dose orthopedic imaging, an advantage in imaging children given the growing concerns regarding radiosensitivity. We have used this system for approximately 1 year for orthopedic imaging of the spine and lower extremities. We have noted advantages of using the digital slot-scanning system when compared with computed radiographic and standard digital radiographic imaging systems, but we also found unexpected but common imaging artifacts that are the direct result of the imaging method and that have not been reported. This pictorial essay serves to familiarize radiologists with the advantages of the digital slot-scanning system as well as imaging artifacts common with this new technology.

  7. Filling Transitions in Acute and Open Wedges.

    Czech Academy of Sciences Publication Activity Database

    Malijevský, Alexandr; Parry, A.O.

    2015-01-01

    Roč. 91, č. 5 (2015), s. 052401 ISSN 1539-3755 R&D Projects: GA ČR GA13-09914S Grant - others:EPSRC(GB) EP/J009636/1; EPSRC(GB) EP/I019111/1 Institutional support: RVO:67985858 Keywords : wetting transitions * wedges * density functional theory Subject RIV: CF - Physical ; Theoretical Chemistry Impact factor: 2.288, year: 2014

  8. Using biplanar fluoroscopy to guide radiopaque vascular injections: a new method for vascular imaging.

    Directory of Open Access Journals (Sweden)

    Haley D O'Brien

    Full Text Available Studying vascular anatomy, especially in the context of relationships with hard tissues, is of great interest to biologists. Vascular studies have provided significant insight into physiology, function, phylogenetic relationships, and evolutionary patterns. Injection of resin or latex into the vascular system has been a standard technique for decades. There has been a recent surge in popularity of more modern methods, especially radiopaque latex vascular injection followed by CT scanning and digital "dissection." This technique best displays both blood vessels and bone, and allows injections to be performed on cadaveric specimens. Vascular injection is risky, however, because it is not a standardizable technique, as each specimen is variable with regard to injection pressure and timing. Moreover, it is not possible to view the perfusion of injection medium throughout the vascular system of interest. Both data and rare specimens can therefore be lost due to poor or excessive perfusion. Here, we use biplanar video fluoroscopy as a technique to guide craniovascular radiopaque latex injection. Cadaveric domestic pigs (Sus scrofa domestica and white-tailed deer (Odocoileus virginianus were injected with radiopaque latex under guidance of fluoroscopy. This method was found to enable adjustments, in real-time, to the rate, location, and pressure at which latex is injected in order to avoid data and specimen loss. In addition to visualizing the injection process, this technique can be used to determine flow patterns, and has facilitated the development of consistent markers for complete perfusion.

  9. In vitro quantification of the performance of model-based mono-planar and bi-planar fluoroscopy for 3D joint kinematics estimation.

    Science.gov (United States)

    Tersi, Luca; Barré, Arnaud; Fantozzi, Silvia; Stagni, Rita

    2013-03-01

    Model-based mono-planar and bi-planar 3D fluoroscopy methods can quantify intact joints kinematics with performance/cost trade-off. The aim of this study was to compare the performances of mono- and bi-planar setups to a marker-based gold-standard, during dynamic phantom knee acquisitions. Absolute pose errors for in-plane parameters were lower than 0.6 mm or 0.6° for both mono- and bi-planar setups. Mono-planar setups resulted critical in quantifying the out-of-plane translation (error mono- (error mono-planar in-plane pose parameters is comparable to bi-planar, but with halved computational costs, halved segmentation time and halved ionizing radiation dose. Bi-planar analysis better compensated for the out-of-plane uncertainty that is differently propagated to relative kinematics depending on the setup. To take its full benefits, the motion task to be investigated should be designed to maintain the joint inside the visible volume introducing constraints with respect to mono-planar analysis.

  10. Comparison of radiation dose, workflow, patient comfort and financial break-even of standard digital radiography and a novel biplanar low-dose X-ray system for upright full-length lower limb and whole spine radiography.

    Science.gov (United States)

    Dietrich, Tobias J; Pfirrmann, Christian W A; Schwab, Alexander; Pankalla, Katja; Buck, Florian M

    2013-07-01

    To compare the radiation dose, workflow, patient comfort, and financial break-even of a standard digital radiography and a biplanar low-dose X-ray system. A standard digital radiography system (Ysio, Siemens Healthcare, Erlangen, Germany) was compared with a biplanar X-ray unit (EOS, EOS imaging, Paris, France) consisting of two X-ray tubes and slot-scanning detectors, arranged at an angle of 90° allowing simultaneous vertical biplanar linear scanning in the upright patient position. We compared data of standing full-length lower limb radiographs and whole spine radiographs of both X-ray systems. Dose-area product was significantly lower for radiographs of the biplanar X-ray system than for the standard digital radiography system (e.g. whole spine radiographs; standard digital radiography system: 392.2 ± 231.7 cGy*cm(2) versus biplanar X-ray system: 158.4 ± 103.8 cGy*cm(2)). The mean examination time was significantly shorter for biplanar radiographs compared with standard digital radiographs (e.g. whole spine radiographs: 449 s vs 248 s). Patients' comfort regarding noise was significantly higher for the standard digital radiography system. The financial break-even point was 2,602 radiographs/year for the standard digital radiography system compared with 4,077 radiographs/year for the biplanar X-ray unit. The biplanar X-ray unit reduces radiation exposure and increases subjective noise exposure to patients. The biplanar X-ray unit demands a higher number of examinations per year for the financial break-even point, despite the lower labour cost per examination due to the shorter examination time.

  11. Comparison of radiation dose, workflow, patient comfort and financial break-even of standard digital radiography and a novel biplanar low-dose X-ray system for upright full-length lower limb and whole spine radiography

    Energy Technology Data Exchange (ETDEWEB)

    Dietrich, Tobias J.; Pfirrmann, Christian W.A.; Pankalla, Katja; Buck, Florian M. [Orthopedic University Hospital Balgrist, Department of Radiology, Zurich (Switzerland); University of Zurich, Zurich (Switzerland); Schwab, Alexander [University of Zurich, Zurich (Switzerland); Orthopedic University Hospital Balgrist, Department of Finances, Zurich (Switzerland)

    2013-07-15

    To compare the radiation dose, workflow, patient comfort, and financial break-even of a standard digital radiography and a biplanar low-dose X-ray system. A standard digital radiography system (Ysio, Siemens Healthcare, Erlangen, Germany) was compared with a biplanar X-ray unit (EOS, EOS imaging, Paris, France) consisting of two X-ray tubes and slot-scanning detectors, arranged at an angle of 90 allowing simultaneous vertical biplanar linear scanning in the upright patient position. We compared data of standing full-length lower limb radiographs and whole spine radiographs of both X-ray systems. Dose-area product was significantly lower for radiographs of the biplanar X-ray system than for the standard digital radiography system (e.g. whole spine radiographs; standard digital radiography system: 392.2 {+-} 231.7 cGy*cm{sup 2} versus biplanar X-ray system: 158.4 {+-} 103.8 cGy*cm{sup 2}). The mean examination time was significantly shorter for biplanar radiographs compared with standard digital radiographs (e.g. whole spine radiographs: 449 s vs 248 s). Patients' comfort regarding noise was significantly higher for the standard digital radiography system. The financial break-even point was 2,602 radiographs/year for the standard digital radiography system compared with 4,077 radiographs/year for the biplanar X-ray unit. The biplanar X-ray unit reduces radiation exposure and increases subjective noise exposure to patients. The biplanar X-ray unit demands a higher number of examinations per year for the financial break-even point, despite the lower labour cost per examination due to the shorter examination time. (orig.)

  12. Influence of patient axial malpositioning on the trueness and precision of pelvic parameters obtained from 3D reconstructions based on biplanar radiographs

    International Nuclear Information System (INIS)

    Ghostine, Bachir; Assi, Ayman; Sauret, Christophe; Skalli, Wafa; Bakouny, Ziad; Khalil, Nour; Ghanem, Ismat

    2017-01-01

    Radiographs are often performed to assess pelvic and hip parameters, but results depend upon correct pelvis positioning. Three-dimensional (3D) reconstruction from biplanar-radiographs should provide parameters that are less sensitive to pelvic orientation, but this remained to be evaluated. Computerized-tomographic scans of six patients were used both as a reference and for generating simulated frontal and lateral radiographs. These simulated radiographs were generated while introducing axial rotations of the pelvis ranging from 0 to 20 . Simulated biplanar-radiographs were utilized by four operators, three times each, to perform pelvic 3D-reconstructions. These reconstructions were used to assess the trueness, precision and global uncertainty of radiological pelvic and hip parameters for each position. In the neutral position, global uncertainty ranged between ± 2 for pelvic tilt and ± 9 for acetabular posterior sector angle and was mainly related to precision errors (ranging from 1.5 to 7 ). With increasing axial rotation, global uncertainty increased and ranged between ± 5 for pelvic tilt and ± 11 for pelvic incidence, sacral slope and acetabular anterior sector angle, mainly due to precision errors. Radiological parameters obtained from 3D-reconstructions, based on biplanar-radiographs, are less sensitive to axial rotation compared to plain radiographs. However, the axial rotation should nonetheless not exceed 10 . (orig.)

  13. Influence of patient axial malpositioning on the trueness and precision of pelvic parameters obtained from 3D reconstructions based on biplanar radiographs

    Energy Technology Data Exchange (ETDEWEB)

    Ghostine, Bachir; Assi, Ayman [Institut de Biomecanique Humaine Georges Charpak, Arts et Metiers ParisTech, Paris (France); University of Saint-Joseph, Laboratory of Biomechanics and Medical Imaging, Faculty of Medicine, Beirut (Lebanon); Sauret, Christophe; Skalli, Wafa [Institut de Biomecanique Humaine Georges Charpak, Arts et Metiers ParisTech, Paris (France); Bakouny, Ziad; Khalil, Nour [University of Saint-Joseph, Laboratory of Biomechanics and Medical Imaging, Faculty of Medicine, Beirut (Lebanon); Ghanem, Ismat [University of Saint-Joseph, Laboratory of Biomechanics and Medical Imaging, Faculty of Medicine, Beirut (Lebanon); University of Saint-Joseph, Hotel-Dieu de France Hospital, Beirut (Lebanon)

    2017-03-15

    Radiographs are often performed to assess pelvic and hip parameters, but results depend upon correct pelvis positioning. Three-dimensional (3D) reconstruction from biplanar-radiographs should provide parameters that are less sensitive to pelvic orientation, but this remained to be evaluated. Computerized-tomographic scans of six patients were used both as a reference and for generating simulated frontal and lateral radiographs. These simulated radiographs were generated while introducing axial rotations of the pelvis ranging from 0 to 20 . Simulated biplanar-radiographs were utilized by four operators, three times each, to perform pelvic 3D-reconstructions. These reconstructions were used to assess the trueness, precision and global uncertainty of radiological pelvic and hip parameters for each position. In the neutral position, global uncertainty ranged between ± 2 for pelvic tilt and ± 9 for acetabular posterior sector angle and was mainly related to precision errors (ranging from 1.5 to 7 ). With increasing axial rotation, global uncertainty increased and ranged between ± 5 for pelvic tilt and ± 11 for pelvic incidence, sacral slope and acetabular anterior sector angle, mainly due to precision errors. Radiological parameters obtained from 3D-reconstructions, based on biplanar-radiographs, are less sensitive to axial rotation compared to plain radiographs. However, the axial rotation should nonetheless not exceed 10 . (orig.)

  14. Correction accuracy and collateral laxity in open versus closed wedge high tibial osteotomy. A one-year randomised controlled study.

    NARCIS (Netherlands)

    Gaasbeek, R.D.A.; Nicolaas, L.; Rijnberg, W.J.; Loon, C.J.M. van; Kampen, A. van

    2010-01-01

    In a randomised clinical trial in 50 patients with symptomatic osteoarthritis of the medial compartment of the knee, the clinical results of high tibial osteotomy (HTO) according to the open wedge osteotomy (OWO) and closed wedge osteotomy (CWO) were compared. In both groups locked plate fixation

  15. Radiographic evaluation of the distal radius using two novel biplanar "pitch-and-roll" views: a preliminary cadaveric study.

    Science.gov (United States)

    Boyce, Brandon M; Ryu, Jaiyoung

    2009-12-01

    This study's objective was to compare the use of two biplanar angled radiographs versus standard posterioanterior (PA) and lateral radiographs in determining preservation of the articular space with regard to pin placement in the distal radius. Various combinations of inclination (pitch) and clockwise/counterclockwise rotation (roll) were used to determine the best view of the distal radius articular surface. Optimum visualization of the articular surface presented at 12 degrees inclination plus 15 degrees counterclockwise rotation for the PA view and 22 degrees inclination and 15 degrees counterclockwise rotation for the lateral view. Ten cadaveric forearms were dissected, and ten Kirschner wires (K-wires) were placed at specific surfaces of the distal radius. Each K-wire was countersunk 2 mm below the chondral surface so all K-wires resided within the subchondral bone. Each forearm was radiographed in four views; PA, lateral, pitch-and-roll PA (PR-PA), and pitch-and-roll lateral (PR-lateral). Four blinded reviewers evaluated the radiographs and marked whether they were certain, relatively certain, or uncertain that the K-wires did not penetrate into the articular space. Reviewers demonstrated significantly less uncertainty about intraarticular penetration (p < 0.005) with both the PR-PA and PR-lateral views compared with standard PA and lateral views. The biconcave nature of the distal radius makes it extremely difficult to visualize placement of hardware with respect to the articular surface using standard radiographs. The use of PR-PA and PR-lateral views significantly improves the surgeon's ability to judge the position of hardware in the distal radius compared to standard radiographic views, thus allowing for more meaningful clinical decision in post-operative radiographs.

  16. Low-dose biplanar radiography can be used in children and adolescents to accurately assess femoral and tibial torsion and greatly reduce irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Meyrignac, Olivier; Baunin, Christiane; Vial, Julie; Sans, Nicolas [CHU Toulouse Purpan, Department of Radiology, Toulouse Cedex 9 (France); Moreno, Ramiro [ALARA Expertise, Oberhausbergen (France); Accadbled, Franck; Gauzy, Jerome Sales de [Hopital des Enfants, Department of Orthopedics, Toulouse Cedex 9 (France); Sommet, Agnes [Universite Paul Sabatier, Department of Fundamental Pharmaco-Clinical Pharmacology, Toulouse (France)

    2015-06-01

    To evaluate in children the agreement between femoral and tibial torsion measurements obtained with low-dose biplanar radiography (LDBR) and CT, and to study dose reduction ratio between these two techniques both in vitro and in vivo. Thirty children with lower limb torsion abnormalities were included in a prospective study. Biplanar radiographs and CTs were performed for measurements of lower limb torsion on each patient. Values were compared using Bland-Altman plots. Interreader and intrareader agreements were evaluated by intraclass correlation coefficients. Comparative dosimetric study was performed using an ionization chamber in a tissue-equivalent phantom, and with thermoluminescent dosimeters in 5 patients. Average differences between CT and LDBR measurements were -0.1 ±1.1 for femoral torsion and -0.7 ±1.4 for tibial torsion. Interreader agreement for LDBR measurements was very good for both femoral torsion (FT) (0.81) and tibial torsion (TT) (0.87). Intrareader agreement was excellent for FT (0.97) and TT (0.89). The ratio between CT scan dose and LDBR dose was 22 in vitro (absorbed dose) and 32 in vivo (skin dose). Lower limb torsion measurements obtained with LDBR are comparable to CT measurements in children and adolescents, with a considerably reduced radiation dose. (orig.)

  17. 1980 Volvo award in clinical sciences. Assessment of patients with low-back pain by biplanar radiographic measurement of intervertebral motion.

    Science.gov (United States)

    Stokes, I A; Wilder, D G; Frymoyer, J W; Pope, M H

    1981-01-01

    Abnormalities of intervertebral joint motion including hypermobility, reduced mobility, torsional abnormality, and displacement of the center of rotation have been associated with degenerative change. However, measurement of these signs in plane X-ray films is handicapped by the three-dimensional motion and geometry of the spine. This study aimed to relate three-dimensional motion of the joints to their pathological state. We have used biplanar radiography to measure intervertebral motion during voluntary movements by patients with low back pain. Primary (or intentional) and coupled motions were measured by a refined technique, along with disc shear and facet joint motion. Abnormalities were found, especially in the "coupled" motions which were related to narrowed disc space, and to proximity to previous fusions. There was asymmetry of motion specific to joints with herniated nucleus pulposus.

  18. Plantar-flexion of the ankle joint complex in terminal stance is initiated by subtalar plantar-flexion: A bi-planar fluoroscopy study.

    Science.gov (United States)

    Koo, Seungbum; Lee, Kyoung Min; Cha, Young Joo

    2015-10-01

    Gross motion of the ankle joint complex (AJC) is a summation of the ankle and subtalar joints. Although AJC kinematics have been widely used to evaluate the function of the AJC, the coordinated movements of the ankle and subtalar joints are not well understood. The purpose of this study was to accurately quantify the individual kinematics of the ankle and subtalar joints in the intact foot during ground walking by using a bi-planar fluoroscopic system. Bi-planar fluoroscopic images of the foot and ankle during walking and standing were acquired from 10 healthy subjects. The three-dimensional movements of the tibia, talus, and calcaneus were calculated with a three-dimensional/two-dimensional registration method. The skeletal kinematics were quantified from 9% to 86% of the full stance phase because of the limited camera speed of the X-ray system. At the beginning of terminal stance, plantar-flexion of the AJC was initiated in the subtalar joint on average at 75% ranging from 62% to 76% of the stance phase, and plantar-flexion of the ankle joint did not start until 86% of the stance phase. The earlier change to plantar-flexion in the AJC than the ankle joint due to the early plantar-flexion in the subtalar joint was observed in 8 of the 10 subjects. This phenomenon could be explained by the absence of direct muscle insertion on the talus. Preceding subtalar plantar-flexion could contribute to efficient and stable ankle plantar-flexion by locking the midtarsal joint, but this explanation needs further investigation. Copyright © 2015 Elsevier B.V. All rights reserved.

  19. Three-dimensional measurements of the lower extremity in children and adolescents using a low-dose biplanar X-ray device

    International Nuclear Information System (INIS)

    Gheno, Ramon; Nectoux, Eric; Herbaux, Bernard; Baldisserotto, Matteo; Glock, Luiz; Cotten, Anne; Boutry, Nathalie

    2012-01-01

    To evaluate three-dimensional (3D) measurements of the lower extremity using a biplanar low-dose X-ray device in children and adolescents. Firstly, 3D measurements of eight dried bones were analysed by a biplanar low-dose X-ray device (LDX) using stereoscopic software and compared with 3D computed tomography (CT). Secondly, 47 lower limbs of children and adolescents were studied using LDX two-dimensional (2D) and 3D measurements. Both parts were evaluated for femoral and tibial lengths and mechanical angles, frontal and lateral knee angulations, and the femoral neck-shaft angle. The 3D specimen comparison between LDX and CT measurements showed no significant differences: femoral length (P = 0.069), tibial length (P = 0.059), femoral mechanical angle (P = 0.475), tibial mechanical angle (P = 0.067), frontal knee angulation (P = 0.198), lateral knee angulation (P = 0.646) and femoral neck-shaft angle (P = 0.068). The comparison between LDX 2D and 3D measurements showed significant differences in tibial length (P = 0.003), femoral mechanical angle (P < 0.001) and femoral neck-shaft angle (P = 0.001); other parameters were unremarkable. The 3D LDX system presented reliable measurements compared with 3D CT. Differences between LDX 2D and 3D measurements were noted in the femoral mechanical angle, femoral neck-shaft angle and tibial length. Moderate to good interobserver agreement for the 3D LDX measurements were found. (orig.)

  20. Development of a bio-mechanical model of the spine based on 3D internal-external relationships: bi-planar radiography and Moire fringes

    International Nuclear Information System (INIS)

    Saunier-Koell, P.

    2010-11-01

    Nowadays, radiography is the gold standard for the follow up of spinal pathologies. Furthermore, bi-planar radiography allows the assessment of vertebrae configuration, by 3-dimensional (3D) reconstruction. However, multiple radiographic examinations during childhood and adolescence increase the risk of breast cancer among women. To reduce radiation doses, some radiographic assessments could be replaced by the back surface evaluation. This kind of non-invasive procedure allows for acquisition of many clinical parameters useful for spinal pathologies diagnosis and follow-up. Moreover, with an appropriate bio mechanical model, the back surface measurements could be used to estimate the spine configuration. The aim of this thesis is to develop and implement such a model based on personalized internal and external data. The Biomod 3S device has been developed by the company AXS MEDICAL SAS, Bordeaux, France. It offers the possibility of simultaneous acquisitions of X-rays and Moire fringes to obtain 3D reconstructions of the spine and the back surface. Such acquisitions on fifteen scoliotic subjects have enabled us to assess several relationships between internal 3D parameters (for example axial rotation of vertebrae) and external 3D parameters (for example rib hump). The spine configuration and the back surface obtained during this acquisition will also be used as initial position to develop (with Scilab) the multi-body model. The other data used by the model are the back surface in a second position and constraints obtained from the surface in both positions (for example displacement of C7 vertebra). The model has been validated on nine healthy subjects, whose 3D spine and back surface were reconstructed in several positions (standing, leaning forward, sitting) from MRI acquisitions. Moreover, the model has been operated on a pathological subject. This work has explored and utilized many spine and back surface information and leads the way to non-invasive diagnosis

  1. Correction for Patient Sway in Radiographic Biplanar Imaging for Three-Dimensional Reconstruction of the Spine: In Vitro Study of a New Method

    Energy Technology Data Exchange (ETDEWEB)

    Legaye, J. (Dept. of Orthopedic Surgery, Univ. of Louvain - Mont-Godinne, Yvoir (Belgium)); Saunier, P.; Dumas, R. (Univ. of Lyon 1 - INRETS, Villeurbanne (France)); Vallee, C. (Radiology Dept., Hpital Raymond Poincare, Garches (France))

    2009-08-15

    Background: Three-dimensional (3D) reconstructions of the spine in the upright position are classically obtained using two-dimensional, non-simultaneous radiographic imaging. However, a subject's sway between exposures induces inaccuracy in the 3D reconstructions. Purpose: To evaluate the impact of patient sway between successive radiographic exposures, and to test if 3D reconstruction accuracy can be improved by a corrective method with simultaneous Moire-X-ray imaging. Material and Methods: Using a calibrated deformable phantom perceptible by both techniques (Moire and X-ray), the 3D positional and rotational vertebral data from 3D reconstructions with and without the corrective procedure were compared to the corresponding data of computed tomography (CT) scans, considered as a reference. All were expressed in the global axis system, as defined by the Scoliosis Research Society. Results: When a sagittal sway of 10 deg occurred between successive biplanar X-rays, the accuracy of the 3D reconstruction without correction was 8.8 mm for the anteroposterior vertebral locations and 6.4 deg for the sagittal orientations. When the corrective method was applied, the accuracy was improved to 1.3 mm and 1.5 deg, respectively. Conclusion: 3D accuracy improved significantly by using the corrective method, whatever the subject's sway. This technique is reliable for clinical appraisal of the spine, if the subject's sway does not exceed 10 deg. For greater sway, improvement persists, but a risk of lack of accuracy exists

  2. Measuring physiological and pathological femoral anteversion using a biplanar low-dose X-ray system: validity, reliability, and discriminative ability in cerebral palsy

    Energy Technology Data Exchange (ETDEWEB)

    Thepaut, Matthias [Laboratoire de Traitement de l' Information Medicale, INSERM U1101, Brest (France); CHRU de Brest, Hopital Morvan, Service de chirurgie pediatrique, Brest (France); Brochard, Sylvain [Laboratoire de Traitement de l' Information Medicale, INSERM U1101, Brest (France); CHRU de Brest, Hopital Morvan, Service de Medecine Physique et de Readaptation, Brest (France); Universite de Bretagne Occidentale, Brest (France); Leboucher, Julien [Laboratoire de Traitement de l' Information Medicale, INSERM U1101, Brest (France); Lempereur, Mathieu [Laboratoire de Traitement de l' Information Medicale, INSERM U1101, Brest (France); CHRU de Brest, Hopital Morvan, Service de Medecine Physique et de Readaptation, Brest (France); Stindel, Eric [Laboratoire de Traitement de l' Information Medicale, INSERM U1101, Brest (France); CHRU de Brest, La Cavale Blanche, Service d' Orthopedie-Traumatologie, Brest (France); Universite de Bretagne Occidentale, Brest (France); Tissot, Valentin [CHRU de Brest, Service de radiologie, Brest (France); Borotikar, Bhushan S. [Laboratoire de Traitement de l' Information Medicale, INSERM U1101, Brest (France); Institut Mines-Telecom, Telecom Bretagne, Brest (France)

    2016-02-15

    The aims of this study were to evaluate the concurrent validity and reliability of a low-dose biplanar X-ray system (Ld-BPR) for the measurement of femoral anteversion (FA) by comparing Ld-BPR-based three-dimensional measures with CT-scan-based measures and to assess the discriminative ability of this method in children with cerebral palsy. Fifty dry femora were scanned using both a CT scan and the Ld-BPR system. Ten femora were artificially modified to mimic a range of anteversion from -30 to +60 and scanned by both modalities. FA was quantified using the images from both modalities and statistically compared for concurrent validity. Intra- and inter-observer reliability of the Ld-BPR system was also determined. Further, Ld-BPR data from 16 hemiplegic and 22 diplegic children were analyzed for its discriminative ability. The concurrent validity between the Ld-BPR and CT-scan measures was excellent (R {sup 2} = 0.83-0.84) and no significant differences were found. The intra- and inter-trial reliability were excellent (ICCs = 0.98 and 0.97) with limits of agreement of (-2.28 ; +2.65 ) and (-2.76 ; +3.38 ) respectively. Further, no significant effects of angle or method were found in the sample of modified femora. Ld-BPR measures for FA were significantly different between healthy and impaired femora. The excellent concurrent validity with the CT scan modality, the excellent reliability, and the ability to discriminate pathological conditions evaluated by this study make this radiological method suitable for a validated use across hospitals and research institutes. (orig.)

  3. Femoral and tibial torsion measurements in children and adolescents: comparison of MRI and 3D models based on low-dose biplanar radiographs

    Energy Technology Data Exchange (ETDEWEB)

    Rosskopf, Andrea B.; Buck, Florian M.; Pfirrmann, Christian W.A. [University Hospital Balgrist, Radiology, Zurich (Switzerland); University of Zurich, Faculty of Medicine, Zurich (Switzerland); Ramseier, Leonhard E. [University of Zurich, Faculty of Medicine, Zurich (Switzerland); University Hospital Balgrist, Department of Orthopedic Surgery, Zurich (Switzerland)

    2017-04-15

    The aim of our study was to evaluate the reliability and interchangeability of femoral (FT) and tibial torsion (TT) measurements in children using magnetic resonance (MR) imaging compared to measurements on 3D models based on biplanar radiographs (BPR). FT and TT were measured in 60 children (mean age 10.1 years; range 6.2-16.2 years; 28 female) using axial MR images by two readers. MR measurements were compared to measurements based on BPR-3D models by two separate independent readers. Interreader and intermethod agreements were calculated using descriptive statistics, the intraclass correlation coefficient (ICC), and Bland-Altman analysis. FT/TT was -8.4 -54.1 /0 -45.9 on MR images and -13 -63 /4 -52 for measurements on BPR-3D models. The median of difference between the two methods was -0.18 (range -13.6 -19.1 ) for FT and -0.20 (range -18.4 -9.5 ) for TT, respectively. Interreader agreement (ICC) of FT/TT measurements was 0.98/0.96 on MR images and 0.98/0.94 on BPR 3D models. Intermethod agreement (ICC) for MR measurements was 0.95 [95% confidence interval (CI), 0.93-0.96] for FT and of 0.86 (CI, 0.24-0.95) for TT. Mean interreader differences at MR were 3.1 (0.0 -8.0 ) for FT and 3.2 (0.1 -9.5 ) for TT. On Bland-Altman plots all measurements were within the 95% limit of agreement (-10.8 ; 11.5 for FT; -14.6 ; 4.2 ) for TT - except for five measurements of FT and six measurements of TT. FT measurements on MR images are comparable to measurements using BPR-3D models. TT measurements differ between the two modalities, but the discrepancy is comparable to measurement variations between CT and BPR. (orig.)

  4. Patella height changes post high tibial osteotomy

    Directory of Open Access Journals (Sweden)

    Siew Ghim Gooi

    2017-01-01

    Full Text Available Background: Medial opening wedge high tibial osteotomy (HTO is a well-described treatment in early medial compartmental osteoarthritis of the knee. However, two undesirable sequelae may follow –patella baja and changes in the posterior tibial slope (TS. Materials and Methods: We conducted a retrospective study in patients who underwent HTO in our center between September 2009 and February 2017. Preoperative and 6-week postoperative long-leg weight bearing films and lateral knee radiographs were assessed. Pre- and postoperative radiological measurements include the Caton-Deschamps Index (CDI, the mechanical axis deviation (MAD, and the posterior TS. Independant t-test and Pearson correlation test were performed. Results: A total of 106 knees were recruited. The mean age was 48.8 ± 10.8 years. 66 (62.3% and 40 (37.7% knees were from males and females, respectively. The mean pre- and postoperative measurements was (−9.70° ± 3.67° to 0.08° ± 2.80° (−varus; +valgus for the MAD, (7.14° ± 1.78° to 8.72° ± 3.11° for posterior TS, and (0.93° ± 0.084° to 0.82° ± 0.13° for CDI (P ≤ 0.001 for all. The association between patella height change and the level of osteotomy (supra-tubercle vs. infra-tubercle was statistically significant (P < 0.001. A supra-tubercle osteotomy cut significantly lowering patella height (P = 0.011. There was otherwise no statistically significant correlations between patella height changes and the correction angle (P = 0.187 or posterior TS change (P = 0.744. Conclusions: A medial opening wedge HTO above the tibial tubercle was significantly associated with lowering patella height or reducing CDI postoperatively. Based on our results, we would recommend the use of an infra-tubercle osteotomy during the corrective surgery to prevent the complication of patella baja.

  5. Development of a bio-mechanical model of the spine based on 3D internal-external relationships: bi-planar radiography and Moire fringes; Developpement d'un modele biomecanique du rachis base sur les relations 3D internes - externes: radiographie bi-planaire et franges de Moire

    Energy Technology Data Exchange (ETDEWEB)

    Saunier-Koell, P.

    2010-11-15

    Nowadays, radiography is the gold standard for the follow up of spinal pathologies. Furthermore, bi-planar radiography allows the assessment of vertebrae configuration, by 3-dimensional (3D) reconstruction. However, multiple radiographic examinations during childhood and adolescence increase the risk of breast cancer among women. To reduce radiation doses, some radiographic assessments could be replaced by the back surface evaluation. This kind of non-invasive procedure allows for acquisition of many clinical parameters useful for spinal pathologies diagnosis and follow-up. Moreover, with an appropriate bio mechanical model, the back surface measurements could be used to estimate the spine configuration. The aim of this thesis is to develop and implement such a model based on personalized internal and external data. The Biomod 3S device has been developed by the company AXS MEDICAL SAS, Bordeaux, France. It offers the possibility of simultaneous acquisitions of X-rays and Moire fringes to obtain 3D reconstructions of the spine and the back surface. Such acquisitions on fifteen scoliotic subjects have enabled us to assess several relationships between internal 3D parameters (for example axial rotation of vertebrae) and external 3D parameters (for example rib hump). The spine configuration and the back surface obtained during this acquisition will also be used as initial position to develop (with Scilab) the multi-body model. The other data used by the model are the back surface in a second position and constraints obtained from the surface in both positions (for example displacement of C7 vertebra). The model has been validated on nine healthy subjects, whose 3D spine and back surface were reconstructed in several positions (standing, leaning forward, sitting) from MRI acquisitions. Moreover, the model has been operated on a pathological subject. This work has explored and utilized many spine and back surface information and leads the way to non-invasive diagnosis

  6. Biplanar variable angle x-ray examining apparatus

    International Nuclear Information System (INIS)

    Grady, J.K.

    1986-01-01

    This invention relates to radiological equipment, particularly to apparatus for supporting and maneuvering a plurality of radiological examination sets to permit simultaneous or sequential exposure through different planes of an organ. The apparatus comprises: a first radiological examining set including a radiation source, receptor, and support for holding the source and receptor along an axis; and a second examining set with the source and receptor aligned to intersect the first axis at a common isocenter. The first support means is rotatable independently of the second support means about a rotational axis intersecting the common isocenter. The support means for one radiological examining set comprises two arms respectively carrying the radiation source and the radiation receptor of the one set and means reciprocally supporting the respective arms for movement independently of each other parallel to the rotational axis, whereby a series of substantially simultaneous radiological examinations can be made on both radiation axes through the subject at variable angles between the axes

  7. Transperineal seed-implantation guided by biplanar transrectal ultrasound

    International Nuclear Information System (INIS)

    Holm, H.H.; Torp-Pedersen, S.; Myschetzky, P.

    1990-01-01

    A new method for precise transperineal placement of therapeutic sources in prostatic cancer is described. The method is a modification of the technique described in 1983 by Holm and coworkers. Insertion of needles is monitored by transverse as well as longitudinal transrectal ultrasound

  8. Transperineal seed-implantation guided by biplanar transrectal ultrasound

    DEFF Research Database (Denmark)

    Holm, Hans Henrik; Torp-Pedersen, S; Myschetzky, P

    1990-01-01

    A new method for precise transperineal placement of therapeutic sources in prostatic cancer is described. The method is a modification of the technique described in 1983 by Holm and coworkers. Insertion of needles is monitored by transverse as well as longitudinal transrectal ultrasound....

  9. Optimization of planar high-dose-rate implants

    International Nuclear Information System (INIS)

    Zwicker, Robert D.; Arthur, Douglas W.; Kavanagh, Brian D.; Mohan, Radhe; Schmidt-Ullrich, Rupert K.

    1999-01-01

    Purpose: Brachytherapy has long been used to deliver localized radiation to the breast and other cancer sites. For interstitial implants, proper source positioning is critical in obtaining satisfactory dose distributions. The present work examines techniques for optimizing source guide placement in high-dose-rate (HDR) biplanar implants, and examines the effects of suboptimal catheter placement. Methods and Materials: Control of individual dwell times in HDR implants allows a high degree of dose uniformity in planes parallel to the implant planes. Biplanar HDR implants can be considered optimized when the dose at the implant center is equal to the dose at the symmetric target boundaries. It is shown that this optimal dose uniformity is achieved when the interplanar separation is related to the target thickness T through the direct proportionality, s = T/√2. To quantify the significance of source positioning, the average dose and a related quantity, equivalent uniform dose (EUD), were calculated inside the treatment volume for two conditions of suboptimal catheter geometry. In one case, the interplanar spacing was varied from 1 cm up to the target thickness T, while a second study examined the effects of off-center placement of the implant planes. Results: Both the average dose and EUD were minimized when the interplanar spacing satisfied the relationship s = T/ √2. EUD, however, was significantly smaller than the average dose, indicating a reduced relative cell killing in the high dose regions near the dwell points. It was also noted that in contrast to the average dose, the EUD is a relatively weak function of catheter misplacement, suggesting that the biological consequences of suboptimal implant geometry may be less significant than is indicated by the increase in average dose. Conclusion: A concise formula can be used to determine the interplanar separation needed for optimal dose uniformity in Manchester-type implants. Deviations from optimal source

  10. Combined intra-articular and varus opening wedge osteotomy for lateral depression and valgus malunion of the proximal part of the tibia. Surgical technique

    NARCIS (Netherlands)

    Kerkhoffs, G.M.M.J.; Rademakers, M.V.; Altena, M.; Marti, R.K.

    2009-01-01

    BACKGROUND: Reconstructive surgical measures for treatment of posttraumatic deformities of the lateral tibial plateau are seldom reported on in the literature. We report the long-term follow-up results of a consecutive series of reconstructive osteotomies performed to treat depression and valgus

  11. Combined intra-articular and varus opening wedge osteotomy for lateral depression and valgus malunion of the proximal part of the Tibia

    NARCIS (Netherlands)

    Kerkhoffs, Gino M. M. J.; Rademakers, Maarten V.; Altena, Mark; Marti, Rene K.

    2008-01-01

    Background: Reconstructive surgical measures for treatment of posttraumatic deformities of the lateral tibial plateau are seldom reported on in the literature. We report the long-term follow-up results of a consecutive series of reconstructive osteotomies performed to treat depression and valgus

  12. Unexplained proximal tibiofibular joint pain after high tibial osteotomy

    Directory of Open Access Journals (Sweden)

    Enrique Adrian Testa

    2014-01-01

    Full Text Available Problems of the proximal tibiofibular joint (pTFj after high tibial osteotomy (HTO are rare. With this case report, we strive to highlight the importance of investigating the pTFj in patients with unexplained knee pain after HTO. A 44 year old male patient presented with diffuse pain on his left knee 3 years after medial opening wedge HTO due to medial compartment overloading in a varus knee. Patient described persistent anterior tibial and lateral knee pain. 2 years after HTO, patient underwent implant removal but the knee pain persisted. As the reason for the persistent pain was not identified, further radiological evaluation was done. Single photon emission computerized tomography/computerized tomography (SPECT/CT revealed that there was no increased uptake within the tibiofemoral joint, indicating a biologically well performed correction of the varus deformity. However, markedly increased tracer uptake was found at the pTFj. On the inherent axial CT scans, it was seen that the proximal screws were too long and placed within the pTFj. Along with this a severe osteoarthritis of the pTFj was identified. The cause of the patient′s pain was then confirmed by a CT guided infiltration of local anesthetic. An arthrodesis of the pTFj was performed and at 12 months followup after the arthrodesis the patient was pain free. This case highlights how important it is to evaluate the pTFj in patients with unexplained pain after HTO. SPECT/CT was helpful in identifying the patient′s problem in this challenging case.

  13. Change in gait after high tibial osteotomy: A systematic review and meta-analysis.

    Science.gov (United States)

    Lee, Seung Hoon; Lee, O-Sung; Teo, Seow Hui; Lee, Yong Seuk

    2017-09-01

    We conducted a meta-analysis to analyze how high tibial osteotomy (HTO) changes gait and focused on the following questions: (1) How does HTO change basic gait variables? (2) How does HTO change the gait variables in the knee joint? Twelve articles were included in the final analysis. A total of 383 knees was evaluated. There were 237 open wedge (OW) and 143 closed wedge (CW) HTOs. There were 4 level II studies and 8 level III studies. All studies included gait analysis and compared pre- and postoperative values. One study compared CWHTO and unicompartmental knee arthroplasty (UKA), and another study compared CWHTO and OWHTO. Five studies compared gait variables with those of healthy controls. One study compared operated limb gait variables with those in the non-operated limb. Gait speed, stride length, knee adduction moment, and lateral thrust were major variables assessed in 2 or more studies. Walking speed increased and stride length was increased or similar after HTO compared to the preoperative value in basic gait variables. Knee adduction moment and lateral thrust were decreased after HTO compared to the preoperative knee joint gait variables. Change in co-contraction of the medial side muscle after surgery differed depending on the degree of frontal plane alignment. The relationship between change in knee adduction moment and change in mechanical axis angle was controversial. Based on our systematic review and meta-analysis, walking speed and stride length increased after HTO. Knee adduction moment and lateral thrust decreased after HTO compared to the preoperative values of gait variables in the knee joint. Copyright © 2017 Elsevier B.V. All rights reserved.

  14. Ritidoplastia compuesta biplanar con restauración de volúmenes

    OpenAIRE

    R.A. Vallarta-Rodríguez; J.J. Ruiz-Treviño; F. Guerrero; E. Ferrero; B.E. Vélez

    2015-01-01

    Las técnicas actuales de rejuvenecimiento facial son producto de años de refinamiento técnico y la máxima expresión de la destreza del cirujano plástico moderno. El rejuvenecimiento del tercio medio facial ha retomado interés recientemente dado que permite reposicionar en bloque los tejidos de la región malar a su posición juvenil original. Como efecto agregado, atenúa el surco nasogeniano por tracción tisular secundaria. Para lograr este efecto se han descrito múltiples abordajes, planos de ...

  15. Ritidoplastia compuesta biplanar con restauración de volúmenes

    Directory of Open Access Journals (Sweden)

    R.A. Vallarta-Rodríguez

    2015-12-01

    Full Text Available Las técnicas actuales de rejuvenecimiento facial son producto de años de refinamiento técnico y la máxima expresión de la destreza del cirujano plástico moderno. El rejuvenecimiento del tercio medio facial ha retomado interés recientemente dado que permite reposicionar en bloque los tejidos de la región malar a su posición juvenil original. Como efecto agregado, atenúa el surco nasogeniano por tracción tisular secundaria. Para lograr este efecto se han descrito múltiples abordajes, planos de disección y métodos de fijación tisular. Las más recientes tendencias quirúrgicas han cambiado el objetivo de la ritidoplastia clásica de ser un procedimiento ablativo, al reposicionamiento volumétrico sin tensión. Este cambio de paradigma permite renovar la arquitectura facial propia del paciente, brindando un resultado más natural, más duradero y con menos complicaciones. Nuestro objetivo es presentar una alternativa quirúrgica para la ritidoplastia manipulando independientemente los vectores tisulares, y permitiendo el restablecimiento volumétrico tridimensional de la región malar. Esto brinda un resultado natural, juvenil y duradero sin el efecto de cara contra el viento que otras técnicas de ritidoplastia ofrecen. Nos permite además tratar la región frontal y cervical en el mismo procedimiento quirúrgico, contribuyendo a un rejuvenecimiento facial integral.

  16. The value of indirect biplanar- and corrected reconstructions for brain CT

    International Nuclear Information System (INIS)

    Imai, Yutaka; Wako, Tadashi; Kasuga, Toshio; Maruyama, Kiyoshi; Kobayashi, Toshio

    1980-01-01

    The normal and pathological anatomy of the brain can be studied in different cross-section planes. Our method employs routine and overlapping scans to reconstruct orthogonal or multiplanar views. All the scans were done with an EMI-1010 scanner, and our studies were carried out by means of the already established computer, TEAC T-16, of the scinticamera and the computer of ECLIPS S/200 of the CT-system in the Department of Radiology, Shinshu University Hospital. The first case is an infarction with scans taken at 15-day intervals done with 5 mm overlapping scans. Both coronal and sagittal views allowed an excellent study of the dimensions of the lesion. Corrected reconstruction to the transverse view from the reconstructed sagittal view was also useful. The second case is a left frontal glioma observed with routine scans. The reconstructed sagittal image shows, postoperative, two loculated spaces, though only a single space was seen in the original scans. The third case is a medulloblastoma of the posterior fossa. Both sagittal and coronal views allowed an exhaustive study of the dimensions of the lesion, as well as of its relation to the ventricular system, in both pre- and postoperative studies with routine scans. The three different planes for the reconstruction of the images are complementary, are of clinical interest, and are particularly useful for an accurate localization of lesions, either for surgical or for radiation-therapy-planning purposes. (author)

  17. A radiolucent chair for sitting-posture radiographs in non-ambulatory children: use in biplanar digital slot-scanning

    International Nuclear Information System (INIS)

    Bouloussa, Houssam; Dubory, Arnaud; Bachy, Manon; Seiler, Catherine; Morel, Baptiste; Vialle, Raphael

    2015-01-01

    EOS imaging (EOS System; EOS imaging, Paris, France) enables fast 2-D/3-D imaging of children in standing load-bearing position. Non-ambulatory children with neuromuscular scoliosis need evaluation of their spinal balance while in a normal daily position. We designed a customized chair fitting the EOS patient-area dimensions to obtain images in natural sitting postures. The chair is a 360 rotating orthopaedic chair made of fully radiolucent polyethylene and equipped with an adjustable headrest and three-point belts. Out of 41 consecutive patients, 36 (88%, 95% confidence interval 74-96%) had successful imaging. In most patients with severe neuromuscular trunk deformities, the EOS system combined with our chair was useful for assessing preoperative trunk collapse, pelvic obliquity and postoperative corrections in all planes. This specific device changed our daily practice for the assessment of spinal deformities in non-ambulatory patients. (orig.)

  18. A radiolucent chair for sitting-posture radiographs in non-ambulatory children: use in biplanar digital slot-scanning

    Energy Technology Data Exchange (ETDEWEB)

    Bouloussa, Houssam; Dubory, Arnaud; Bachy, Manon [Universite Pierre et Marie Curie-Paris 6, Armand Trousseau Hospital, Department of Pediatric Orthopaedics, Paris Cedex 12 (France); Seiler, Catherine [Groupe Lagarrigue, Clichy (France); Morel, Baptiste [Universite Pierre et Marie Curie-Paris 6, Armand Trousseau Hospital, Department of Pediatric Imaging, Paris (France); Vialle, Raphael [Universite Pierre et Marie Curie-Paris 6, Armand Trousseau Hospital, Department of Pediatric Orthopaedics, Paris Cedex 12 (France); Armand Trousseau Hospital, The MAMUTH Hospital-University Department for Innovative Therapies in Musculoskeletal Diseases, Paris (France)

    2015-11-15

    EOS imaging (EOS System; EOS imaging, Paris, France) enables fast 2-D/3-D imaging of children in standing load-bearing position. Non-ambulatory children with neuromuscular scoliosis need evaluation of their spinal balance while in a normal daily position. We designed a customized chair fitting the EOS patient-area dimensions to obtain images in natural sitting postures. The chair is a 360 rotating orthopaedic chair made of fully radiolucent polyethylene and equipped with an adjustable headrest and three-point belts. Out of 41 consecutive patients, 36 (88%, 95% confidence interval 74-96%) had successful imaging. In most patients with severe neuromuscular trunk deformities, the EOS system combined with our chair was useful for assessing preoperative trunk collapse, pelvic obliquity and postoperative corrections in all planes. This specific device changed our daily practice for the assessment of spinal deformities in non-ambulatory patients. (orig.)

  19. A radiolucent chair for sitting-posture radiographs in non-ambulatory children: use in biplanar digital slot-scanning.

    Science.gov (United States)

    Bouloussa, Houssam; Dubory, Arnaud; Seiler, Catherine; Morel, Baptiste; Bachy, Manon; Vialle, Raphaël

    2015-11-01

    EOS imaging (EOS System; EOS imaging, Paris, France) enables fast 2-D/3-D imaging of children in standing load-bearing position. Non-ambulatory children with neuromuscular scoliosis need evaluation of their spinal balance while in a normal daily position. We designed a customized chair fitting the EOS patient-area dimensions to obtain images in natural sitting postures. The chair is a 360° rotating orthopaedic chair made of fully radiolucent polyethylene and equipped with an adjustable headrest and three-point belts. Out of 41 consecutive patients, 36 (88%, 95% confidence interval 74-96%) had successful imaging. In most patients with severe neuromuscular trunk deformities, the EOS system combined with our chair was useful for assessing preoperative trunk collapse, pelvic obliquity and postoperative corrections in all planes. This specific device changed our daily practice for the assessment of spinal deformities in non-ambulatory patients.

  20. Three-dimensional reconstructions for asymptomatic and cerebral palsy children's lower limbs using a biplanar X-ray system: A feasibility study

    Energy Technology Data Exchange (ETDEWEB)

    Assi, Ayman, E-mail: ayman.assi@gmail.com [Laboratoire de Biomécanique, Arts et Métiers ParisTech, Paris (France); Laboratory of Biomechanics, Faculty of Medicine, University of Saint-Joseph, Beirut (Lebanon); Gait and Motion Analysis Lab, SESOBEL, Beirut (Lebanon); Chaibi, Yasmina, E-mail: yasmina.chaibi@gmail.com [Laboratoire de Biomécanique, Arts et Métiers ParisTech, Paris (France); Presedo, Ana, E-mail: a.presedo@gmail.com [Laboratoire de Biomécanique, Arts et Métiers ParisTech, Paris (France); Hôpital Robert Debré, Paris (France); Dubousset, Jean, E-mail: jean.dubousset@wanadoo.fr [Laboratoire de Biomécanique, Arts et Métiers ParisTech, Paris (France); Ghanem, Ismat, E-mail: ghanem.i@dm.net.lb [Laboratory of Biomechanics, Faculty of Medicine, University of Saint-Joseph, Beirut (Lebanon); Gait and Motion Analysis Lab, SESOBEL, Beirut (Lebanon); Hôpital Hôtel Dieu de France, Beirut (Lebanon); Skalli, Wafa, E-mail: wafa.skalli@ensam.eu [Laboratoire de Biomécanique, Arts et Métiers ParisTech, Paris (France)

    2013-12-01

    The aim of this study is to explore the feasibility of 3D subject-specific skeletal reconstructions of lower limb in children using stereoradiography, and to assess uncertainty of clinical and anatomical parameters for children with cerebral palsy and for healthy children. The stereoradiography technique, using the EOS{sup ®} system (Eos-imaging{sup ®}), is based on the acquisition of two simultaneous digital anteroposterior and lateral X-rays, from head to feet in standing position and at low radiation dose. This technique allows subject-specific skeletal 3D reconstructions. Five children with cerebral palsy (CP) and 5 typically developing children (TD) were included in the study. Two operators performed the lower limb reconstructions twice. Tridimensional reconstructions were feasible for children over the age of 5 years. The study of reproducibility of anatomical parameters defining skeletal alignment showed uncertainties under 3° for the neck shaft angle, the femoral mechanical angle, and for the femoral and tibial torsions. The maximum degree of uncertainty was obtained for the femoral tibial rotation (4° for healthy children and 3.5° for children with CP)

  1. Three-dimensional quantitative analysis of the proximal femur and the pelvis in children and adolescents using an upright biplanar slot-scanning X-ray system

    Energy Technology Data Exchange (ETDEWEB)

    Szuper, Kinga; Schlegl, Adam Tibor; Vermes, Csaba; Somoskeoey, Szabolcs; Than, Peter [University of Pecs, Department of Orthopaedics, Institute of Musculoskeletal Surgery, Clinical Centre, Pecs (Hungary); Leidecker, Eleonora [University of Pecs, Institute of Physiotherapy and Nutritional Sciences, Faculty of Health Sciences, Pecs (Hungary)

    2015-03-01

    The anatomy and biomechanics of the pelvis and lower limbs play a key role in the development of orthopaedic disorders. This study aimed to establish normal reference standards for the measurement of gender-specific pelvic and femoral parameters in children and adolescents with the EOS 2-D/3-D system. EOS 2-D images of 508 individuals (ages 4-16 years) were obtained as part of routine diagnostics. Patients with lower limb abnormalities were excluded. Pelvic and femoral surface 3-D models were generated and clinical parameters calculated by sterEOS 3-D reconstruction software. Data were evaluated using Spearman correlation, paired-samples and independent-samples t-test and linear regression analysis. Changes in anatomical parameters were found to correlate with age and gender in (1) femoral mechanical axis length: 27.3-43.7 cm (males), 25.5-41.2 cm (females), (2) femoral head diameter: 29.4-46.1 mm (males), 27.7-41.3 mm (females), (3) femoral offset: 26.8-42.4 mm (males), 25.5-37.9 mm (females) and (4) femoral neck length: 35.1-52.9 mm (males), 32.8-48.1 mm (females). There was no gender-specific correlation for the neck shaft angle with values from 130.4 to 129.3 , for femoral torsion (22.5 -19.4 ), for sacral slope (39.0 -44.4 ) and for lateral pelvic tilt (5.1 mm-6.2 mm). Sagittal pelvic tilt exhibited no significant correlation with age showing average values of 6.5 . The EOS 2-D/3-D system proved to be a valuable method in the evaluation of female and male developmental changes in pelvic and lower limb anatomical parameters, in normal individuals younger than 16 years of age. (orig.)

  2. Comparison of plantar pressure, clinical, and radiographic changes of the forefoot after biplanar Austin osteotomy and triplanar Boc osteotomy in patients with mild hallux valgus.

    Science.gov (United States)

    Cancilleri, Francesco; Marinozzi, Andrea; Martinelli, Nicolò; Ippolito, Massimiliano; Spiezia, Filippo; Ronconi, Paolo; Denaro, Vincenzo

    2008-08-01

    Boc's modification of the Austin procedure is a triplane distal osteotomy that achieves shortening and plantarflexion of the first metatarsal with a lateral translation of the metatarsal head. The clinical results and influence of the Austin and Boc osteotomies on plantar pressure have been compared retrospectively. The patients were divided into two groups: 30 Austin and 30 Boc osteotomies were performed with a mean followup of 37 (range, 29 to 56) months. Sixty patients with mild hallux valgus deformities and central metatarsalgia, took part in the study. Pressure measurements were performed with a Diagnostic Support system footplate. The average postoperative American Orthopaedic Foot and Ankle Society score of the Austin group was 81.9 and 86.4 for the Boc group. The pressure distributions under the fourth and fifth metatarsal head were comparable in both groups (p>0.05). The Austin group showed decreased load bearing under the hallux and the first metatarsal head (p0.05). The Boc group showed decreased weightbearing under the hallux with better load distribution beneath the second and the third metatarsal head (pBoc triplane osteotomy seems to restore more physiologic loading of the forefoot in comparison to the Austin procedure, reducing the incidence of painful callus under the second and third metatarsal head.

  3. Three-dimensional reconstructions for asymptomatic and cerebral palsy children's lower limbs using a biplanar X-ray system: A feasibility study

    International Nuclear Information System (INIS)

    Assi, Ayman; Chaibi, Yasmina; Presedo, Ana; Dubousset, Jean; Ghanem, Ismat; Skalli, Wafa

    2013-01-01

    The aim of this study is to explore the feasibility of 3D subject-specific skeletal reconstructions of lower limb in children using stereoradiography, and to assess uncertainty of clinical and anatomical parameters for children with cerebral palsy and for healthy children. The stereoradiography technique, using the EOS ® system (Eos-imaging ® ), is based on the acquisition of two simultaneous digital anteroposterior and lateral X-rays, from head to feet in standing position and at low radiation dose. This technique allows subject-specific skeletal 3D reconstructions. Five children with cerebral palsy (CP) and 5 typically developing children (TD) were included in the study. Two operators performed the lower limb reconstructions twice. Tridimensional reconstructions were feasible for children over the age of 5 years. The study of reproducibility of anatomical parameters defining skeletal alignment showed uncertainties under 3° for the neck shaft angle, the femoral mechanical angle, and for the femoral and tibial torsions. The maximum degree of uncertainty was obtained for the femoral tibial rotation (4° for healthy children and 3.5° for children with CP)

  4. High arch

    Science.gov (United States)

    ... pes cavus. High arch is the opposite of flat feet . ... High foot arches are much less common than flat feet. They are more likely to be caused by a bone (orthopedic) or nerve (neurological) condition. Unlike ...

  5. High Line

    DEFF Research Database (Denmark)

    Kiib, Hans

    2015-01-01

    . The High Line project has been carried out as part of an open conversion strategy. The result is a remarkable urban architectural project, which works as a catalyst for the urban development of Western Manhattan. The greater project includes the restoration and reuse of many old industrial buildings......At just over 10 meters above street level, the High Line extends three kilometers through three districts of Southwestern Manhattan in New York. It consists of simple steel construction, and previously served as an elevated rail line connection between Penn Station on 34th Street and the many...... in close proximity to the park bridge and new projects being added to fit the context. The outcome is a conglomeration of non-contemporary urban activities along the High Line, where mechanical workshops, small wholesale stores. etc. mix with new exclusive residential buildings, eminent cafés...

  6. High Turbulence

    CERN Multimedia

    EuHIT, Collaboration

    2015-01-01

    As a member of the EuHIT (European High-Performance Infrastructures in Turbulence - see here) consortium, CERN is participating in fundamental research on turbulence phenomena. To this end, the Laboratory provides European researchers with a cryogenic research infrastructure (see here), where the first tests have just been performed.

  7. High Class

    Science.gov (United States)

    Waldecker, Mark

    2005-01-01

    Education administrators make buying decisions for furniture based on many factors. Cost, durability, functionality, safety and aesthetics represent just a few. Those issues always will be important, but gaining greater recognition in recent years has been the role furniture plays in creating positive, high-performance learning environments. The…

  8. Highly dominating, highly authoritarian personalities.

    Science.gov (United States)

    Altemeyer, Bob

    2004-08-01

    The author considered the small part of the population whose members score highly on both the Social Dominance Orientation scale and the Right-Wing Authoritarianism scale. Studies of these High SDO-High RWAs, culled from samples of nearly 4000 Canadian university students and over 2600 of their parents and reported in the present article, reveal that these dominating authoritarians are among the most prejudiced persons in society. Furthermore, they seem to combine the worst elements of each kind of personality, being power-hungry, unsupportive of equality, manipulative, and amoral, as social dominators are in general, while also being religiously ethnocentric and dogmatic, as right-wing authoritarians tend to be. The author suggested that, although they are small in number, such persons can have considerable impact on society because they are well-positioned to become the leaders of prejudiced right-wing political movements.

  9. Highly efficient high temperature electrolysis

    DEFF Research Database (Denmark)

    Hauch, Anne; Ebbesen, Sune; Jensen, Søren Højgaard

    2008-01-01

    electrolysis is favourable from a thermodynamic point of view, because a part of the required energy can be supplied as thermal heat, and the activation barrier is lowered increasing the H-2 production rate. Only two types of cells operating at high temperature (above 200 degrees C) have been described...... electrolysis using SOECs is competitive to H-2 production from fossil fuels at electricity prices below 0.02-0.03 is an element of per kWh. Though promising SOEC results on H-2 production have been reported a substantial R&D is still required to obtain inexpensive, high performing and long-term stable...

  10. High Energy $\

    CERN Multimedia

    2002-01-01

    This experiment is a high statistics exposure of BEBC filled with hydrogen to both @n and &bar.@n beams. The principal physics aims are : \\item a) The study of the production of charmed mesons and baryons using fully constrained events. \\end{enumerate} b) The study of neutral current interactions on the free proton. \\item c) Measurement of the cross-sections for production of exclusive final state N* and @D resonances. \\item d) Studies of hadronic final states in charged and neutral current reactions. \\item e) Measurement of inclusive charged current cross-sections and structure functions. \\end{enumerate}\\\\ \\\\ The neutrino flux is determined by monitoring the flux of muons in the neutrino shield. The Internal Picket Fence and External Muon Identifier of BEBC are essential parts of the experiment. High resolution cameras are used to search for visible decays of short-lived particles.

  11. High energy

    International Nuclear Information System (INIS)

    Bonner, B.E.; Roberts, J.B. Jr.

    1993-01-01

    We report here on progress made for the period from December 1, 1992 (the date of submission of our latest progress report) to November 30, 1993 for DOE Grant No. DE-FG05-92ER40717. The new results from the SMC experiment have generated a buzz of theoretical activity. Our involvement with the D0 experiment and the upgrade has increased substantially during the past two years so that we now have six people heavily committed and making what can only be described as a large and disproportionate impact on D0 physics output. Some of the new developments made here at Rice in Neural Network and Probability Density Estimation techniques for data analysis promise to have applications both in D0 and beyond. We report a load of new results from our high-p t jet photoproduction experiment. In addition we have been working on KTeV, albeit without having adequate funding for this work. Progress on the theoretical front has been nothing short of amazing, as is reported herein. In a grand lecture tour during this sabbatical year, Paul Stevenson has already reported his breakthroughs at ten institutions, including CERN, Oxford, Cambridge, Rutherford Lab, Imperial College, and Durham University. The group at Rice University has had an exceptionally productive year and we are justifiably proud of the progress which is reported here

  12. Comparison of Puddu osteotomy with or without autologous bone grafting: a prospective clinical trial

    Directory of Open Access Journals (Sweden)

    Marcus Ceregatti Passarelli

    Full Text Available ABSTRACT Objectives: To test the hypothesis that autologous iliac bone grafts do not enhance clinical results and do not decrease complication rates in patients undergoing medial opening-wedge high tibial , osteotomy. Methods: Forty patients allocated in a randomized, two-armed, double-blinded clinical trial were evaluated between 2007 and 2010. One group received bone graft, and the other group was left without filling the osteotomy defect. The primary outcome was the Knee Society Score. , Radiographic measurement of the frontal anatomical femoral-tibial angle and the progression of osteoarthritis according to the modified Ahlback classification were used as secondary outcomes., Results: There was no difference in KSS scale between the graft group (64.4 ± 21.8 and the graftless group (61.6 ± 17.3; p= 0.309. There was no difference of angle between the femur and tibia in the frontal plane between the groups (graft, = 184 ± 4.6 degrees, graftless = 183.4 ± 5.1 degrees; p= 1.0, indicating that there is no loss of correction due to the lack of the graft. There was significant aggravation of osteoarthritis in a greater number of patients in a graft group (p= 0.005 . Conclusion: Autologous iliac bone graft does not improve clinical outcomes in medium and long-term follow-up of medial opening-wedge high tibial osteotomy fixed with a first generation Puddu plate in the conditions of this study.

  13. High Combustion Research Facility

    Data.gov (United States)

    Federal Laboratory Consortium — At NETL's High-Pressure Combustion Research Facility in Morgantown, WV, researchers can investigate new high-pressure, high-temperature hydrogen turbine combustion...

  14. High Blood Pressure (Hypertension)

    Science.gov (United States)

    ... Print Page Text Size: A A A Listen High Blood Pressure (Hypertension) Nearly 1 in 3 American adults has high ... weight. How Will I Know if I Have High Blood Pressure? High blood pressure is a silent problem — you ...

  15. High Performance Networks for High Impact Science

    Energy Technology Data Exchange (ETDEWEB)

    Scott, Mary A.; Bair, Raymond A.

    2003-02-13

    This workshop was the first major activity in developing a strategic plan for high-performance networking in the Office of Science. Held August 13 through 15, 2002, it brought together a selection of end users, especially representing the emerging, high-visibility initiatives, and network visionaries to identify opportunities and begin defining the path forward.

  16. Hyperglycemia (High Blood Glucose)

    Medline Plus

    Full Text Available ... Español Hyperglycemia (High Blood Glucose) Hyperglycemia is the technical term for high blood glucose (blood sugar). High ... We Are Research Leaders We Support Your Doctor Student Resources Patient Access to Research Research Resources Practice ...

  17. Hyperglycemia (High Blood Glucose)

    Medline Plus

    Full Text Available ... Español Hyperglycemia (High Blood Glucose) Hyperglycemia is the technical term for high blood glucose (blood sugar). High ... Type 2 Diabetes program to get help and support during your first year. Featured Book Type 2 ...

  18. High Blood Cholesterol

    Science.gov (United States)

    ... To Health Topics / High Blood Cholesterol High Blood Cholesterol Also known as Hypercholesterolemia High blood cholesterol is ... Lipid panel tests to check for healthy blood cholesterol levels Doctors use lipid panels to check whether ...

  19. High Blood Pressure Facts

    Science.gov (United States)

    ... Stroke Heart Disease Cholesterol Salt Million Hearts® WISEWOMAN High Blood Pressure Facts Recommend on Facebook Tweet Share Compartir On ... Top of Page CDC Fact Sheets Related to High Blood Pressure High Blood Pressure Pulmonary Hypertension Heart Disease Signs ...

  20. High Blood Pressure

    Science.gov (United States)

    ... normal blood pressure 140/90 or higher is high blood pressure Between 120 and 139 for the top number, ... prehypertension. Prehypertension means you may end up with high blood pressure, unless you take steps to prevent it. High ...

  1. Development of high strength, high temperature ceramics

    Science.gov (United States)

    Hall, W. B.

    1982-01-01

    Improvement in the high-pressure turbopumps, both fuel and oxidizer, in the Space Shuttle main engine were considered. The operation of these pumps is limited by temperature restrictions of the metallic components used in these pumps. Ceramic materials that retain strength at high temperatures and appear to be promising candidates for use as turbine blades and impellers are discussed. These high strength materials are sensitive to many related processing parameters such as impurities, sintering aids, reaction aids, particle size, processing temperature, and post thermal treatment. The specific objectives of the study were to: (1) identify and define the processing parameters that affect the properties of Si3N4 ceramic materials, (2) design and assembly equipment required for processing high strength ceramics, (3) design and assemble test apparatus for evaluating the high temperature properties of Si3N4, and (4) conduct a research program of manufacturing and evaluating Si3N4 materials as applicable to rocket engine applications.

  2. High Throughput Facility

    Data.gov (United States)

    Federal Laboratory Consortium — Argonne?s high throughput facility provides highly automated and parallel approaches to material and materials chemistry development. The facility allows scientists...

  3. Hyperglycemia (High Blood Glucose)

    Medline Plus

    Full Text Available ... Diagnosing Diabetes and Learning About Prediabetes Type 2 Diabetes Risk Test Lower Your Risk Healthy Eating Overweight Smoking High Blood Pressure Physical Activity High Blood ...

  4. Bumball: Highly Engaging, Highly Inclusive, and Highly Entertaining

    Science.gov (United States)

    Hall, Amber; Barney, David; Wilkinson, Carol

    2014-01-01

    Physical educators are always looking for new and exciting games and activities in which students can participate. This article describes Bumball, a high-intensity game that provides the opportunity for students to use many common game skills, such as hand-eye coordination, passing to a target, running, playing defense, and getting to an open…

  5. Editorial Commentary: Results of Biplanar Fluoroscopy With 3-Dimensional Analysis in Patients With Rotator Cuff Tears Challenge the Concept of Superior Translation of the Humeral Head and Must Be Interpreted With Caution.

    Science.gov (United States)

    Rossi, Michael J

    2016-03-01

    Kinematic analysis of patients with rotator cuff tears shows unexpected inferior, rather than superior, translation of the humeral head. This paradox challenges conventional thought, but limitations addressed by the authors temper the results and leave the question open for future study. Copyright © 2016 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.

  6. Why high energy physics

    International Nuclear Information System (INIS)

    Diddens, A.N.; Van de Walle, R.T.

    1981-01-01

    An argument is presented for high energy physics from the point of view of the practitioners. Three different angles are presented: The cultural consequence and scientific significance of practising high energy physics, the potential application of the results and the discovery of high energy physics, and the technical spin-offs from the techniques and methods used in high energy physics. (C.F.)

  7. High performance pulse generator

    Science.gov (United States)

    Grothaus, Michael G.; Moran, Stuart L.; Hardesty, Leonard W.

    1992-06-01

    The device is a compact Marx-type generator capable of producing a high-voltage burst of pulses having risetimes less than 10 nanoseconds at repetition rates up to 10 kHz. High-pressure hydrogen switches are used as the switching elements to achieve high rep-rate. A small coaxial design provides low inductance and a fast risetime. The device may be used as a high-rep-rate high-voltage trigger generator, or as a high-voltage pulse source capable of producing up to 1 MV pulses at high repetition rates.

  8. High Temperature, High Power Piezoelectric Composite Transducers

    Directory of Open Access Journals (Sweden)

    Hyeong Jae Lee

    2014-08-01

    Full Text Available Piezoelectric composites are a class of functional materials consisting of piezoelectric active materials and non-piezoelectric passive polymers, mechanically attached together to form different connectivities. These composites have several advantages compared to conventional piezoelectric ceramics and polymers, including improved electromechanical properties, mechanical flexibility and the ability to tailor properties by using several different connectivity patterns. These advantages have led to the improvement of overall transducer performance, such as transducer sensitivity and bandwidth, resulting in rapid implementation of piezoelectric composites in medical imaging ultrasounds and other acoustic transducers. Recently, new piezoelectric composite transducers have been developed with optimized composite components that have improved thermal stability and mechanical quality factors, making them promising candidates for high temperature, high power transducer applications, such as therapeutic ultrasound, high power ultrasonic wirebonding, high temperature non-destructive testing, and downhole energy harvesting. This paper will present recent developments of piezoelectric composite technology for high temperature and high power applications. The concerns and limitations of using piezoelectric composites will also be discussed, and the expected future research directions will be outlined.

  9. High Temperature, High Power Piezoelectric Composite Transducers

    Science.gov (United States)

    Lee, Hyeong Jae; Zhang, Shujun; Bar-Cohen, Yoseph; Sherrit, StewarT.

    2014-01-01

    Piezoelectric composites are a class of functional materials consisting of piezoelectric active materials and non-piezoelectric passive polymers, mechanically attached together to form different connectivities. These composites have several advantages compared to conventional piezoelectric ceramics and polymers, including improved electromechanical properties, mechanical flexibility and the ability to tailor properties by using several different connectivity patterns. These advantages have led to the improvement of overall transducer performance, such as transducer sensitivity and bandwidth, resulting in rapid implementation of piezoelectric composites in medical imaging ultrasounds and other acoustic transducers. Recently, new piezoelectric composite transducers have been developed with optimized composite components that have improved thermal stability and mechanical quality factors, making them promising candidates for high temperature, high power transducer applications, such as therapeutic ultrasound, high power ultrasonic wirebonding, high temperature non-destructive testing, and downhole energy harvesting. This paper will present recent developments of piezoelectric composite technology for high temperature and high power applications. The concerns and limitations of using piezoelectric composites will also be discussed, and the expected future research directions will be outlined. PMID:25111242

  10. Highly Accreting Quasars at High Redshift

    Directory of Open Access Journals (Sweden)

    Mary L. Martínez-Aldama

    2018-01-01

    Full Text Available We present preliminary results of a spectroscopic analysis for a sample of type 1 highly accreting quasars (L/LEdd ~ 1.0 at high redshift, z ~2–3. The quasars were observed with the OSIRIS spectrograph on the GTC 10.4 m telescope located at the Observatorio del Roque de los Muchachos in La Palma. The highly accreting quasars were identified using the 4D Eigenvector 1 formalism, which is able to organize type 1 quasars over a broad range of redshift and luminosity. The kinematic and physical properties of the broad line region have been derived by fitting the profiles of strong UV emission lines such as Aliiiλ1860, Siiii]λ1892 and Ciii]λ1909. The majority of our sources show strong blueshifts in the high-ionization lines and high Eddington ratios which are related with the productions of outflows. The importance of highly accreting quasars goes beyond a detailed understanding of their physics: their extreme Eddington ratio makes them candidates standard candles for cosmological studies.

  11. High temperature, high power piezoelectric composite transducers.

    Science.gov (United States)

    Lee, Hyeong Jae; Zhang, Shujun; Bar-Cohen, Yoseph; Sherrit, Stewart

    2014-08-08

    Piezoelectric composites are a class of functional materials consisting of piezoelectric active materials and non-piezoelectric passive polymers, mechanically attached together to form different connectivities. These composites have several advantages compared to conventional piezoelectric ceramics and polymers, including improved electromechanical properties, mechanical flexibility and the ability to tailor properties by using several different connectivity patterns. These advantages have led to the improvement of overall transducer performance, such as transducer sensitivity and bandwidth, resulting in rapid implementation of piezoelectric composites in medical imaging ultrasounds and other acoustic transducers. Recently, new piezoelectric composite transducers have been developed with optimized composite components that have improved thermal stability and mechanical quality factors, making them promising candidates for high temperature, high power transducer applications, such as therapeutic ultrasound, high power ultrasonic wirebonding, high temperature non-destructive testing, and downhole energy harvesting. This paper will present recent developments of piezoelectric composite technology for high temperature and high power applications. The concerns and limitations of using piezoelectric composites will also be discussed, and the expected future research directions will be outlined.

  12. High concentration agglomerate dynamics at high temperatures.

    Science.gov (United States)

    Heine, M C; Pratsinis, S E

    2006-11-21

    The dynamics of agglomerate aerosols are investigated at high solids concentrations that are typical in industrial scale manufacture of fine particles (precursor mole fraction larger than 10 mol %). In particular, formation and growth of fumed silica at such concentrations by chemical reaction, coagulation, and sintering is simulated at nonisothermal conditions and compared to limited experimental data and commercial product specifications. Using recent chemical kinetics for silica formation by SiCl4 hydrolysis and neglecting aerosol polydispersity, the evolution of the diameter of primary particles (specific surface area, SSA), hard- and soft-agglomerates, along with agglomerate effective volume fraction (volume occupied by agglomerate) is investigated. Classic Smoluchowski theory is fundamentally limited for description of soft-agglomerate Brownian coagulation at high solids concentrations. In fact, these high concentrations affect little the primary particle diameter (or SSA) but dominate the soft-agglomerate diameter, structure, and volume fraction, leading to gelation consistent with experimental data. This indicates that restructuring and fragmentation should affect product particle characteristics during high-temperature synthesis of nanostructured particles at high concentrations in aerosol flow reactors.

  13. Hyperglycemia (High Blood Glucose)

    Medline Plus

    Full Text Available ... Risk Healthy Eating Overweight Smoking High Blood Pressure Physical Activity High Blood Glucose My Health Advisor Tools To Know Your Risk Alert Day Diabetes Basics Home Symptoms Diagnosis America's Diabetes Challenge Type ...

  14. Hyperglycemia (High Blood Glucose)

    Medline Plus

    Full Text Available ... Prediabetes Type 2 Diabetes Risk Test Lower Your Risk Healthy Eating Overweight Smoking High Blood Pressure Physical Activity High Blood Glucose My Health Advisor Tools To Know Your Risk Alert Day Diabetes Basics Home Symptoms Diagnosis America's ...

  15. Hyperglycemia (High Blood Glucose)

    Medline Plus

    Full Text Available ... Risk Test Lower Your Risk Healthy Eating Overweight Smoking High Blood Pressure Physical Activity High Blood Glucose ... Day in the Life of Diabetes Famous People Working to Stop Diabetes Common Terms Diabetes Statistics Infographics ...

  16. Hyperglycemia (High Blood Glucose)

    Medline Plus

    Full Text Available ... to Give Close Are You at Risk? Home Prevention Diagnosing Diabetes and Learning About Prediabetes Type 2 Diabetes Risk Test Lower Your Risk Healthy Eating Overweight Smoking High Blood Pressure Physical Activity High Blood Glucose ...

  17. Hyperglycemia (High Blood Glucose)

    Medline Plus

    Full Text Available ... Healthy Eating Overweight Smoking High Blood Pressure Physical Activity High Blood Glucose My Health Advisor Tools To ... Started Safely Get And Stay Fit Types of Activity Weight Loss Assess Your Lifestyle Getting Started Food ...

  18. Hyperglycemia (High Blood Glucose)

    Medline Plus

    Full Text Available ... Overweight Smoking High Blood Pressure Physical Activity High Blood Glucose My Health Advisor Tools To Know Your Risk Alert Day Diabetes Basics Home Symptoms Diagnosis America's Diabetes Challenge Type 1 Type 2 Facts About Type 2 Enroll ...

  19. Hyperglycemia (High Blood Glucose)

    Medline Plus

    Full Text Available ... Diabetes Risk Test Lower Your Risk Healthy Eating Overweight Smoking High Blood Pressure Physical Activity High Blood ... For Parents & Kids Safe at School Everyday Life Children and Type 2 Diabetes Know Your Rights Employment ...

  20. Hyperglycemia (High Blood Glucose)

    Medline Plus

    Full Text Available ... 2 Diabetes Risk Test Lower Your Risk Healthy Eating Overweight Smoking High Blood Pressure Physical Activity High ... What Can I Drink? Fruit Dairy Food Tips Eating Out Quick Meal Ideas Snacks Nutrient Content Claims ...

  1. Hyperglycemia (High Blood Glucose)

    Medline Plus

    Full Text Available ... Prediabetes Type 2 Diabetes Risk Test Lower Your Risk Healthy Eating Overweight Smoking High Blood Pressure Physical Activity High Blood Glucose My Health Advisor Tools To Know Your Risk Alert Day ...

  2. High blood pressure medications

    Science.gov (United States)

    ... this page: //medlineplus.gov/ency/article/007484.htm High blood pressure medicines To use the sharing features on this page, please enable JavaScript. Treating high blood pressure will help prevent problems such as heart disease, ...

  3. High blood pressure - children

    Science.gov (United States)

    ... this page: //medlineplus.gov/ency/article/007696.htm High blood pressure - children To use the sharing features on this page, please enable JavaScript. High blood pressure (hypertension) is an increase in the force of ...

  4. Hyperglycemia (High Blood Glucose)

    Medline Plus

    Full Text Available ... Risk Healthy Eating Overweight Smoking High Blood Pressure Physical Activity High Blood Glucose My Health Advisor Tools ... Find Your Local Office Find your local diabetes education program Calendar of Events Wellness Lives Here Awareness ...

  5. Hyperglycemia (High Blood Glucose)

    Medline Plus

    Full Text Available ... Risk Test Lower Your Risk Healthy Eating Overweight Smoking High Blood Pressure Physical Activity High Blood Glucose ... Clinical Practice Guidelines Patient Education Materials Scientific Sessions Journals for Professionals Professional Books Patient Access to Research ...

  6. Hyperglycemia (High Blood Glucose)

    Medline Plus

    Full Text Available ... and Learning About Prediabetes Type 2 Diabetes Risk Test Lower Your Risk Healthy Eating Overweight Smoking High Blood Pressure Physical Activity High Blood Glucose My Health Advisor Tools ...

  7. Hyperglycemia (High Blood Glucose)

    Medline Plus

    Full Text Available ... Test Lower Your Risk Healthy Eating Overweight Smoking High Blood Pressure Physical Activity High Blood Glucose My Health Advisor ... Quick Meal Ideas Snacks Nutrient Content Claims Understanding Carbohydrates Types of Carbohydrates Carbohydrate Counting Make Your Carbs ...

  8. Preventing High Blood Pressure

    Science.gov (United States)

    ... Heart Disease Cholesterol Salt Million Hearts® WISEWOMAN Preventing High Blood Pressure: Healthy Living Habits Recommend on Facebook Tweet Share ... meal and snack options can help you avoid high blood pressure and its complications. Be sure to eat plenty ...

  9. High blood pressure - infants

    Science.gov (United States)

    Hypertension - infants ... and blood vessels The health of the kidneys High blood pressure in infants may be due to kidney or ... blood vessel of the kidney) In newborn babies, high blood pressure is often caused by a blood clot in ...

  10. Hyperglycemia (High Blood Glucose)

    Medline Plus

    Full Text Available ... Diagnosing Diabetes and Learning About Prediabetes Type 2 Diabetes Risk Test Lower Your Risk Healthy Eating Overweight Smoking High Blood Pressure Physical Activity High Blood Glucose My Health Advisor ...

  11. Hyperglycemia (High Blood Glucose)

    Medline Plus

    Full Text Available ... and Learning About Prediabetes Type 2 Diabetes Risk Test Lower Your Risk Healthy Eating Overweight Smoking High Blood Pressure Physical Activity High Blood Glucose My Health ...

  12. High speed data acquisition

    International Nuclear Information System (INIS)

    Cooper, P.S.

    1997-07-01

    A general introduction to high speed data acquisition system techniques in modern particle physics experiments is given. Examples are drawn from the SELEX(E78 1) high statistics charmed baryon production and decay experiment now taking data at Fermilab

  13. Hyperglycemia (High Blood Glucose)

    Medline Plus

    Full Text Available ... symptoms include the following: High blood glucose High levels of sugar in the urine Frequent urination Increased ... you should check and what your blood glucose levels should be. Checking your blood and then treating ...

  14. High current and high power superconducting rectifiers

    NARCIS (Netherlands)

    ten Kate, Herman H.J.; Bunk, P.B.; Britton, R.B.; van de Klundert, L.J.M.

    1981-01-01

    Results on three experimental superconducting rectifiers are reported. Two of them are 1 kA low frequency flux pumps, one thermally and magnetically switched. The third is a low-current high-frequency magnetically switched rectifier which can use the mains directly.

  15. New high performances fluoroelastomers

    Energy Technology Data Exchange (ETDEWEB)

    Arcella, Vincenzo; Brinati, Giulio; Apostolo, Marco [Ausimont R and D, Bollate (Italy)

    1997-03-01

    Fluoroelastomers are amorphous polymers designed for high demanding applications in hostile environments. The presence of fluorine in the polymer backbone imparts to the structure the ability to withstand very high temperatures and, at the same time, high resistance to chemical attack. However, the presence of fluorine is also a source of drawbacks, such as high chain stiffness and difficulties to obtain permanent networks. In the present paper recent Ausimont developments in the field of fluoroelastomers are presented.

  16. High-pressure microbiology

    National Research Council Canada - National Science Library

    Michiels, Chris; Bartlett, Douglas Hoyt; Aertsen, Abram

    2008-01-01

    ... . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1. High Hydrostatic Pressure Effects in the Biosphere: from Molecules to Microbiology * Filip Meersman and Karel Heremans . . . . . . . . . . . . 2. Effects...

  17. High energy neutron radiography

    International Nuclear Information System (INIS)

    Gavron, A.; Morley, K.; Morris, C.; Seestrom, S.; Ullmann, J.; Yates, G.; Zumbro, J.

    1996-01-01

    High-energy spallation neutron sources are now being considered in the US and elsewhere as a replacement for neutron beams produced by reactors. High-energy and high intensity neutron beams, produced by unmoderated spallation sources, open potential new vistas of neutron radiography. The authors discuss the basic advantages and disadvantages of high-energy neutron radiography, and consider some experimental results obtained at the Weapons Neutron Research (WNR) facility at Los Alamos

  18. Tunable high pressure lasers

    Science.gov (United States)

    Hess, R. V.

    1976-01-01

    Atmospheric transmission of high energy CO2 lasers is considerably improved by high pressure operation which, due to pressure broadening, permits tuning the laser lines off atmospheric absorption lines. Pronounced improvement is shown for horizontal transmission at altitudes above several kilometers and for vertical transmission through the entire atmosphere. Applications of tunable high pressure CO2 lasers to energy transmission and to remote sensing are discussed along with initial efforts in tuning high pressure CO2 lasers.

  19. High resolution, high speed ultrahigh vacuum microscopy

    International Nuclear Information System (INIS)

    Poppa, Helmut

    2004-01-01

    The history and future of transmission electron microscopy (TEM) is discussed as it refers to the eventual development of instruments and techniques applicable to the real time in situ investigation of surface processes with high resolution. To reach this objective, it was necessary to transform conventional high resolution instruments so that an ultrahigh vacuum (UHV) environment at the sample site was created, that access to the sample by various in situ sample modification procedures was provided, and that in situ sample exchanges with other integrated surface analytical systems became possible. Furthermore, high resolution image acquisition systems had to be developed to take advantage of the high speed imaging capabilities of projection imaging microscopes. These changes to conventional electron microscopy and its uses were slowly realized in a few international laboratories over a period of almost 40 years by a relatively small number of researchers crucially interested in advancing the state of the art of electron microscopy and its applications to diverse areas of interest; often concentrating on the nucleation, growth, and properties of thin films on well defined material surfaces. A part of this review is dedicated to the recognition of the major contributions to surface and thin film science by these pioneers. Finally, some of the important current developments in aberration corrected electron optics and eventual adaptations to in situ UHV microscopy are discussed. As a result of all the path breaking developments that have led to today's highly sophisticated UHV-TEM systems, integrated fundamental studies are now possible that combine many traditional surface science approaches. Combined investigations to date have involved in situ and ex situ surface microscopies such as scanning tunneling microscopy/atomic force microscopy, scanning Auger microscopy, and photoemission electron microscopy, and area-integrating techniques such as x-ray photoelectron

  20. Early College High Schools

    Science.gov (United States)

    Dessoff, Alan

    2011-01-01

    For at-risk students who stand little chance of going to college, or even finishing high school, a growing number of districts have found a solution: Give them an early start in college while they still are in high school. The early college high school (ECHS) movement that began with funding from the Bill and Melinda Gates Foundation 10 years ago…

  1. High performance systems

    Energy Technology Data Exchange (ETDEWEB)

    Vigil, M.B. [comp.

    1995-03-01

    This document provides a written compilation of the presentations and viewgraphs from the 1994 Conference on High Speed Computing given at the High Speed Computing Conference, {open_quotes}High Performance Systems,{close_quotes} held at Gleneden Beach, Oregon, on April 18 through 21, 1994.

  2. High pressure and high temperature apparatus

    Science.gov (United States)

    Voronov, Oleg A.

    2005-09-13

    A design for high pressure/high temperature apparatus and reaction cell to achieve .about.30 GPa pressure in .about.1 cm volume and .about.100 GPa pressure in .about.1 mm volumes and 20-5000.degree. C. temperatures in a static regime. The device includes profiled anvils (28) action on a reaction cell (14, 16) containing the material (26) to be processed. The reaction cell includes a heater (18) surrounded by insulating layers and screens. Surrounding the anvils are cylindrical inserts and supporting rings (30-48) whose hardness increases towards the reaction cell. These volumes may be increased considerably if applications require it, making use of presses that have larger loading force capability, larger frames and using larger anvils.

  3. High frequency, high power capacitor development

    Science.gov (United States)

    White, C. W.; Hoffman, P. S.

    1983-01-01

    A program to develop a special high energy density, high power transfer capacitor to operate at frequency of 40 kHz, 600 V rms at 125 A rms plus 600 V dc bias for space operation. The program included material evaluation and selection, a capacitor design was prepared, a thermal analysis performed on the design. Fifty capacitors were manufactured for testing at 10 kHz and 40 kHz for 50 hours at Industrial Electric Heating Co. of Columbus, Ohio. The vacuum endurance test used on environmental chamber and temperature plate furnished by Maxwell. The capacitors were energized with a special power conditioning apparatus developed by Industrial Electric Heating Co. Temperature conditions of the capacitors were monitored by IEHCo test equipment. Successful completion of the vacuum endurance test series confirmed achievement of the main goal of producing a capacitor or reliable operation at high frequency in an environment normally not hospitable to electrical and electronic components. The capacitor developed compared to a typical commercial capacitor at the 40 kHz level represents a decrease in size and weight by a factor of seven.

  4. High performance homes

    DEFF Research Database (Denmark)

    Beim, Anne; Vibæk, Kasper Sánchez

    2014-01-01

    Can prefabrication contribute to the development of high performance homes? To answer this question, this chapter defines high performance in more broadly inclusive terms, acknowledging the technical, architectural, social and economic conditions under which energy consumption and production occur....... Consideration of all these factors is a precondition for a truly integrated practice and as this chapter demonstrates, innovative project delivery methods founded on the manufacturing of prefabricated buildings contribute to the production of high performance homes that are cost effective to construct, energy...

  5. High temperature refrigerator

    International Nuclear Information System (INIS)

    Steyert, W.A. Jr.

    1978-01-01

    A high temperature magnetic refrigerator is described which uses a Stirling-like cycle in which rotating magnetic working material is heated in zero field and adiabatically magnetized, cooled in high field, then adiabatically demagnetized. During this cycle the working material is in heat exchange with a pumped fluid which absorbs heat from a low temperature heat source and deposits heat in a high temperature reservoir. The magnetic refrigeration cycle operates at an efficiency 70% of Carnot

  6. High Redshift GRBs

    Science.gov (United States)

    Gehrels, Neil; Cannizzo, John K.

    2012-01-01

    The Swift mission has opened a new, high redshift window on the universe. In this review we provide an overview of gamma-ray burst (GRB) science, describe the Swift mission, discuss high-z GRBs and tools for high-z studies, and look forward at future capabilities. A new mission concept - Lobster - is described that would monitor the X-ray sky at order of magnitude higher sensitivity than current missions.

  7. High-Temperature Superconductivity

    Science.gov (United States)

    Tanaka, Shoji

    2006-12-01

    A general review on high-temperature superconductivity was made. After prehistoric view and the process of discovery were stated, the special features of high-temperature superconductors were explained from the materials side and the physical properties side. The present status on applications of high-temperature superconductors were explained on superconducting tapes, electric power cables, magnets for maglev trains, electric motors, superconducting quantum interference device (SQUID) and single flux quantum (SFQ) devices and circuits.

  8. High temperature refrigerator

    Science.gov (United States)

    Steyert, Jr., William A.

    1978-01-01

    A high temperature magnetic refrigerator which uses a Stirling-like cycle in which rotating magnetic working material is heated in zero field and adiabatically magnetized, cooled in high field, then adiabatically demagnetized. During this cycle said working material is in heat exchange with a pumped fluid which absorbs heat from a low temperature heat source and deposits heat in a high temperature reservoir. The magnetic refrigeration cycle operates at an efficiency 70% of Carnot.

  9. High enthalpy gas dynamics

    CERN Document Server

    Rathakrishnan, Ethirajan

    2014-01-01

    This is an introductory level textbook which explains the elements of high temperature and high-speed gas dynamics. written in a clear and easy to follow style, the author covers all the latest developments in the field including basic thermodynamic principles, compressible flow regimes and waves propagation in one volume covers theoretical modeling of High Enthalpy Flows, with particular focus on problems in internal and external gas-dynamic flows, of interest in the fields of rockets propulsion and hypersonic aerodynamics High enthalpy gas dynamics is a compulsory course for aerospace engine

  10. High blood cholesterol levels

    Science.gov (United States)

    Cholesterol - high; Lipid disorders; Hyperlipoproteinemia; Hyperlipidemia; Dyslipidemia; Hypercholesterolemia ... There are many types of cholesterol. The ones talked about most are: ... lipoprotein (HDL) cholesterol -- often called "good" cholesterol ...

  11. Athletes at High Altitude.

    Science.gov (United States)

    Khodaee, Morteza; Grothe, Heather L; Seyfert, Jonathan H; VanBaak, Karin

    2016-01-01

    Athletes at different skill levels perform strenuous physical activity at high altitude for a variety of reasons. Multiple team and endurance events are held at high altitude and may place athletes at increased risk for developing acute high altitude illness (AHAI). Training at high altitude has been a routine part of preparation for some of the high level athletes for a long time. There is a general belief that altitude training improves athletic performance for competitive and recreational athletes. A review of relevant publications between 1980 and 2015 was completed using PubMed and Google Scholar. Clinical review. Level 3. AHAI is a relatively uncommon and potentially serious condition among travelers to altitudes above 2500 m. The broad term AHAI includes several syndromes such as acute mountain sickness (AMS), high altitude pulmonary edema (HAPE), and high altitude cerebral edema (HACE). Athletes may be at higher risk for developing AHAI due to faster ascent and more vigorous exertion compared with nonathletes. Evidence regarding the effects of altitude training on athletic performance is weak. The natural live high, train low altitude training strategy may provide the best protocol for enhancing endurance performance in elite and subelite athletes. High altitude sports are generally safe for recreational athletes, but they should be aware of their individual risks. Individualized and appropriate acclimatization is an essential component of injury and illness prevention.

  12. High voltage engineering

    CERN Document Server

    Rizk, Farouk AM

    2014-01-01

    Inspired by a new revival of worldwide interest in extra-high-voltage (EHV) and ultra-high-voltage (UHV) transmission, High Voltage Engineering merges the latest research with the extensive experience of the best in the field to deliver a comprehensive treatment of electrical insulation systems for the next generation of utility engineers and electric power professionals. The book offers extensive coverage of the physical basis of high-voltage engineering, from insulation stress and strength to lightning attachment and protection and beyond. Presenting information critical to the design, selec

  13. Hyperglycemia (High Blood Glucose)

    Medline Plus

    Full Text Available ... A A A Listen En Español Hyperglycemia (High Blood Glucose) Hyperglycemia is the technical term for high ... function (data) { $('#survey-errors').remove(); $('.survey-form .form-group .survey-alert-wrap').remove(); if (data.submitSurveyResponse.success == ' ...

  14. High Blood Pressure (Hypertension)

    Science.gov (United States)

    ... other risk factors, like diabetes, you may need treatment. How does high blood pressure affect pregnant women? A few women will get ... HIV, Birth Control Heart Health for Women Pregnancy Menopause More Women's Health ... High Blood Pressure--Medicines to Help You Women and Diabetes Heart ...

  15. Hyperglycemia (High Blood Glucose)

    Medline Plus

    Full Text Available ... Diagnosing Diabetes and Learning About Prediabetes Type 2 Diabetes Risk Test Lower Your Risk Healthy Eating Overweight Smoking High Blood Pressure Physical Activity High Blood Glucose My Health Advisor Tools To Know Your Risk Alert Day Diabetes Basics ...

  16. Hyperglycemia (High Blood Glucose)

    Medline Plus

    Full Text Available ... Research & Practice Ways to Give Close Are You at Risk? Home Prevention Diagnosing Diabetes and Learning About Prediabetes Type 2 Diabetes Risk Test Lower Your Risk Healthy Eating Overweight Smoking High Blood Pressure Physical Activity High Blood Glucose ...

  17. Very high energy colliders

    International Nuclear Information System (INIS)

    Richter, B.

    1986-03-01

    The luminosity and energy requirements are considered for both proton colliders and electron-positron colliders. Some of the basic design equations for high energy linear electron colliders are summarized, as well as design constraints. A few examples are given of parameters for very high energy machines. 4 refs., 6 figs

  18. Proxmox high availability

    CERN Document Server

    Cheng, Simon MC

    2014-01-01

    If you want to know the secrets of virtualization and how to implement high availability on your services, this is the book for you. For those of you who are already using Proxmox, this book offers you the chance to build a high availability cluster with a distributed filesystem to further protect your system from failure.

  19. High coking value pitch

    Energy Technology Data Exchange (ETDEWEB)

    Miller, Douglas J.; Chang, Ching-Feng; Lewis, Irwin C.; Lewis, Richard T.

    2014-06-10

    A high coking value pitch prepared from coal tar distillate and has a low softening point and a high carbon value while containing substantially no quinoline insolubles is disclosed. The pitch can be used as an impregnant or binder for producing carbon and graphite articles.

  20. Hyperglycemia (High Blood Glucose)

    Medline Plus

    Full Text Available ... around 4:00 a.m. to 5:00 a.m.). What are the Symptoms of Hyperglycemia? The signs and symptoms include the following: High blood glucose High levels of sugar in the urine Frequent urination Increased ...

  1. High Productivity Aluminum Manufacturing

    Science.gov (United States)

    2013-07-01

    recommended not to continue this program to the planned second year, Phase 2 tasks. 15. SUBJECT TERMS butt welding, LCS, high deposition , GMAW...10 Figure 1B High Deposition GMAW...and length of the “stem of wine glass” for each weld condition

  2. High-Conflict Divorce.

    Science.gov (United States)

    Johnston, Janet R.

    1994-01-01

    Reviews available research studies of high-conflict divorce and its effects on children. Factors believed to contribute to high-conflict divorce are explored, and a model of their interrelationships is proposed. Dispute resolution, intervention, and prevention programs are discussed, and implications for social policy are outlined. (SLD)

  3. Hyperglycemia (High Blood Glucose)

    Medline Plus

    Full Text Available ... You at Risk? Home Prevention Diagnosing Diabetes and Learning About Prediabetes Type 2 Diabetes Risk Test Lower Your Risk Healthy Eating Overweight Smoking High Blood Pressure Physical Activity High Blood Glucose My Health Advisor Tools To Know Your Risk Alert Day Diabetes Basics ...

  4. Hyperglycemia (High Blood Glucose)

    Medline Plus

    Full Text Available ... Risk Healthy Eating Overweight Smoking High Blood Pressure Physical Activity High Blood Glucose My Health Advisor Tools To Know ... We Support Your Doctor Clinical Practice Guidelines Patient Education Materials Scientific ... for School Projects How to Reference Our Site Diabetes Basics ...

  5. Inexpensive high vacuum feedthroughs.

    Science.gov (United States)

    Gerber, S.; Post, D.

    1973-01-01

    Description of the use of rigid coaxial cable in the construction of high vacuum coaxial and coaxial push-pull rotary motion feedthroughs. This type of feedthroughs is shown to be extremely cheap and simple to make and modify. It can be used for moderately high voltages and provides a continuous, well shielded, low-noise feedthrough cable in any desired configuration.

  6. Hyperglycemia (High Blood Glucose)

    Medline Plus

    Full Text Available ... Type 2 Diabetes Risk Test Lower Your Risk Healthy Eating Overweight Smoking High Blood Pressure Physical Activity High ... Holiday Meal Planning What Can I Eat? Making Healthy Food Choices Diabetes ... Tips Eating Out Quick Meal Ideas Snacks Nutrient Content Claims ...

  7. Hyperglycemia (High Blood Glucose)

    Medline Plus

    Full Text Available ... Your Carbs Count Glycemic Index Low-Calorie Sweeteners Sugar and Desserts Fitness Exercise & Type 1 Diabetes Get Started Safely Get And Stay Fit Types ... the following: High blood glucose High levels of sugar in the ... Part of managing your diabetes is checking your blood glucose often. Ask your ...

  8. High-pressure apparatus

    NARCIS (Netherlands)

    Schepdael, van L.J.M.; Bartels, P.V.; Berg, van den R.W.

    1999-01-01

    The invention relates to a high-pressure device (1) having a cylindrical high-pressure vessel (3) and prestressing means in order to exert an axial pressure on the vessel. The vessel (3) can have been formed from a number of layers of composite material, such as glass, carbon or aramide fibers which

  9. High potassium level

    Science.gov (United States)

    ... level URL of this page: //medlineplus.gov/ency/article/001179.htm High potassium level To use the sharing features on this page, ... There are often no symptoms with a high level of potassium. When symptoms do occur, they may include: Nausea Slow, weak, or irregular pulse Sudden collapse, when ...

  10. High temperature sensor

    Science.gov (United States)

    Tokarz, Richard D.

    1982-01-01

    A high temperature sensor includes a pair of electrical conductors separated by a mass of electrical insulating material. The insulating material has a measurable resistivity within the sensor that changes in relation to the temperature of the insulating material within a high temperature range (1,000 to 2,000 K.). When required, the sensor can be encased within a ceramic protective coating.

  11. High-pressure crystallography

    Science.gov (United States)

    Katrusiak, A.

    2008-01-01

    The history and development of high-pressure crystallography are briefly described and examples of structural transformations in compressed compounds are given. The review is focused on the diamond-anvil cell, celebrating its 50th anniversary this year, the principles of its operation and the impact it has had on high-pressure X-ray diffraction.

  12. High assurance services computing

    CERN Document Server

    2009-01-01

    Covers service-oriented technologies in different domains including high assurance systemsAssists software engineers from industry and government laboratories who develop mission-critical software, and simultaneously provides academia with a practitioner's outlook on the problems of high-assurance software development

  13. Chemistry of high energies

    International Nuclear Information System (INIS)

    Bugaenko, L.T.; Kuz'min, M.G.; Polak, L.S.

    1988-01-01

    An attempt was made to integrate plasma chemistry, radiation chemistry and photochemistry under the name of ''Chemistry of high energies''. Theoretical background of these disciplines, as well as principles of their technology (methods of energy supply, methods of absorbed energy determination, apparatus and processes) are considered. Application of processes of high energy chemistry in engineering is discussed. 464 refs.; 85 figs.; 59 tabs

  14. High Performance Marine Vessels

    CERN Document Server

    Yun, Liang

    2012-01-01

    High Performance Marine Vessels (HPMVs) range from the Fast Ferries to the latest high speed Navy Craft, including competition power boats and hydroplanes, hydrofoils, hovercraft, catamarans and other multi-hull craft. High Performance Marine Vessels covers the main concepts of HPMVs and discusses historical background, design features, services that have been successful and not so successful, and some sample data of the range of HPMVs to date. Included is a comparison of all HPMVs craft and the differences between them and descriptions of performance (hydrodynamics and aerodynamics). Readers will find a comprehensive overview of the design, development and building of HPMVs. In summary, this book: Focuses on technology at the aero-marine interface Covers the full range of high performance marine vessel concepts Explains the historical development of various HPMVs Discusses ferries, racing and pleasure craft, as well as utility and military missions High Performance Marine Vessels is an ideal book for student...

  15. High current high accuracy IGBT pulse generator

    International Nuclear Information System (INIS)

    Nesterov, V.V.; Donaldson, A.R.

    1995-05-01

    A solid state pulse generator capable of delivering high current triangular or trapezoidal pulses into an inductive load has been developed at SLAC. Energy stored in a capacitor bank of the pulse generator is switched to the load through a pair of insulated gate bipolar transistors (IGBT). The circuit can then recover the remaining energy and transfer it back to the capacitor bank without reversing the capacitor voltage. A third IGBT device is employed to control the initial charge to the capacitor bank, a command charging technique, and to compensate for pulse to pulse power losses. The rack mounted pulse generator contains a 525 μF capacitor bank. It can deliver 500 A at 900V into inductive loads up to 3 mH. The current amplitude and discharge time are controlled to 0.02% accuracy by a precision controller through the SLAC central computer system. This pulse generator drives a series pair of extraction dipoles

  16. High redshift quasars and high metallicities

    Science.gov (United States)

    Ferland, Gary J.

    1997-01-01

    A large-scale code called Cloudy was designed to simulate non-equilibrium plasmas and predict their spectra. The goal was to apply it to studies of galactic and extragalactic emission line objects in order to reliably deduce abundances and luminosities. Quasars are of particular interest because they are the most luminous objects in the universe and the highest redshift objects that can be observed spectroscopically, and their emission lines can reveal the composition of the interstellar medium (ISM) of the universe when it was well under a billion years old. The lines are produced by warm (approximately 10(sup 4)K) gas with moderate to low density (n less than or equal to 10(sup 12) cm(sup -3)). Cloudy has been extended to include approximately 10(sup 4) resonance lines from the 495 possible stages of ionization of the lightest 30 elements, an extension that required several steps. The charge transfer database was expanded to complete the needed reactions between hydrogen and the first four ions and fit all reactions with a common approximation. Radiative recombination rate coefficients were derived for recombination from all closed shells, where this process should dominate. Analytical fits to Opacity Project (OP) and other recent photoionization cross sections were produced. Finally, rescaled OP oscillator strengths were used to compile a complete set of data for 5971 resonance lines. The major discovery has been that high redshift quasars have very high metallicities and there is strong evidence that the quasar phenomenon is associated with the birth of massive elliptical galaxies.

  17. High-pressure microfluidics

    Science.gov (United States)

    Hjort, K.

    2015-03-01

    When using appropriate materials and microfabrication techniques, with the small dimensions the mechanical stability of microstructured devices allows for processes at high pressures without loss in safety. The largest area of applications has been demonstrated in green chemistry and bioprocesses, where extraction, synthesis and analyses often excel at high densities and high temperatures. This is accessible through high pressures. Capillary chemistry has been used since long but, just like in low-pressure applications, there are several potential advantages in using microfluidic platforms, e.g., planar isothermal set-ups, large local variations in geometries, dense form factors, small dead volumes and precisely positioned microstructures for control of reactions, catalysis, mixing and separation. Other potential applications are in, e.g., microhydraulics, exploration, gas driven vehicles, and high-pressure science. From a review of the state-of-art and frontiers of high pressure microfluidics, the focus will be on different solutions demonstrated for microfluidic handling at high pressures and challenges that remain.

  18. High power VME system

    International Nuclear Information System (INIS)

    Murakami, T.

    1990-01-01

    While the power consumption of CAMAC and VME modules is less than 40 watts per module and that of TKO and FASTBUS is much more, the former group consumes twice as much power per unit surface area as the latter group. The area occupied by components amounts to 60 percent of the total board area in TKO Super Controller Head Module and to 83 percent in VME Memory Partner module. Such a high packing density results in a high power density, and cooling of such modules becomes difficult. Despite these, such electronics systems with very high packing density are expected to become popular. The present report summarizes studies on various aspects of high power systems. The studies cover the cooling, routing power, and resistance to fire. A forced air cooling unit for TKO is developed. It serves to achieve a very high air flow rate for cooling, but high power systems would require better temperature compensation than other systems since one cannot expect a uniform ambient temperature distribution to be achieved over the board surface. It might even prohibit high resolution circuits to function to full capacity. Another study is made on a backplane that can supply much more current than conventional ones. A special power connector is developed which can supply currents up to 50 ampere. (N.K.)

  19. High current ion sources

    International Nuclear Information System (INIS)

    Brown, I.G.

    1989-06-01

    The concept of high current ion source is both relative and evolutionary. Within the domain of one particular kind of ion source technology a current of microamperers might be 'high', while in another area a current of 10 Amperes could 'low'. Even within the domain of a single ion source type, what is considered high current performance today is routinely eclipsed by better performance and higher current output within a short period of time. Within their fields of application, there is a large number of kinds of ion sources that can justifiably be called high current. Thus, as a very limited example only, PIGs, Freemen sources, ECR sources, duoplasmatrons, field emission sources, and a great many more all have their high current variants. High current ion beams of gaseous and metallic species can be generated in a number of different ways. Ion sources of the kind developed at various laboratories around the world for the production of intense neutral beams for controlled fusion experiments are used to form large area proton deuteron beams of may tens of Amperes, and this technology can be used for other applications also. There has been significant progress in recent years in the use of microwave ion sources for high current ion beam generation, and this method is likely to find wide application in various different field application. Finally, high current beams of metal ions can be produced using metal vapor vacuum arc ion source technology. After a brief consideration of high current ion source design concepts, these three particular methods are reviewed in this paper

  20. High flying physics

    International Nuclear Information System (INIS)

    Anon.

    1981-01-01

    Cosmic ray physicists have always had to aim high. In the constant search for interactions produced as close as possible to the immensely high primary particles entering the earth's atmosphere from outer space, they have installed experiments on high mountain peaks and flown detectors aloft in balloons. In these studies, there have been periodic sightings of remarkable configurations of secondary particles. These events, many of which bear exotic names like Centauro, Andromeda, Texas Lone Star, etc., frequently defy explanation in terms of conventional physics ideas and give a glimpse of what may lie beyond the behaviour seen so far under laboratory conditions

  1. High voltage test techniques

    CERN Document Server

    Kind, Dieter

    2001-01-01

    The second edition of High Voltage Test Techniques has been completely revised. The present revision takes into account the latest international developments in High Voltage and Measurement technology, making it an essential reference for engineers in the testing field.High Voltage Technology belongs to the traditional area of Electrical Engineering. However, this is not to say that the area has stood still. New insulating materials, computing methods and voltage levels repeatedly pose new problems or open up methods of solution; electromagnetic compatibility (EMC) or components and systems al

  2. High-density lipoprotein cholesterol: How High

    Directory of Open Access Journals (Sweden)

    G Rajagopal

    2012-01-01

    Full Text Available The high-density lipoprotein cholesterol (HDL-C is considered anti-atherogenic good cholesterol. It is involved in reverse transport of lipids. Epidemiological studies have found inverse relationship of HDL-C and coronary heart disease (CHD risk. When grouped according to HDL-C, subjects having HDL-C more than 60 mg/dL had lesser risk of CHD than those having HDL-C of 40-60 mg/dL, who in turn had lesser risk than those who had HDL-C less than 40 mg/dL. No upper limit for beneficial effect of HDL-C on CHD risk has been identified. The goals of treating patients with low HDL-C have not been firmly established. Though many drugs are known to improve HDL-C concentration, statins are proven to improve CHD risk and mortality. Cholesteryl ester transfer protein (CETP is involved in metabolism of HDL-C and its inhibitors are actively being screened for clinical utility. However, final answer is still awaited on CETP-inhibitors.

  3. High-tech entrepreneurship

    DEFF Research Database (Denmark)

    Bernasconi, Michel; Harris, Simon; Mønsted, Mette

    planning models, and also means that the management skills used in this area must be more responsive to issues of risk, uncertainty and evaluation than in conventional business opportunities. Whilst entrepreneurial courses do reflect the importance of high-tech businesses, they often lack the resources......; entrepreneurial finance; marketing technological innovations; and high-tech incubation management. Including case studies to give practical insights into genuine business examples, this comprehensive book has a distinctly 'real-world' focus throughout.Edited by a multi-national team, this comprehensive book...... focuses on the blend of theory and practice needed to inform advanced entrepreneurship students of the specifics of high-tech start-ups. Key topics covered include: uncertainty and innovation; entrepreneurial finance; marketing technological innovations; and high-tech incubation management...

  4. Hyperglycemia (High Blood Glucose)

    Medline Plus

    Full Text Available ... your blood and then treating high blood glucose early will help you avoid problems associated with hyperglycemia. ... to detect hyperglycemia so you can treat it early — before it gets worse. If you're new ...

  5. High-Speed Photography

    International Nuclear Information System (INIS)

    Paisley, D.L.; Schelev, M.Y.

    1998-01-01

    The applications of high-speed photography to a diverse set of subjects including inertial confinement fusion, laser surgical procedures, communications, automotive airbags, lightning etc. are briefly discussed. (AIP) copyright 1998 Society of Photo-Optical Instrumentation Engineers

  6. High Performance Macromolecular Material

    National Research Council Canada - National Science Library

    Forest, M

    2002-01-01

    .... In essence, most commercial high-performance polymers are processed through fiber spinning, following Nature and spider silk, which is still pound-for-pound the toughest liquid crystalline polymer...

  7. High Performance Macromolecular Materials

    National Research Council Canada - National Science Library

    Forest, M. G; Choate, Eric; Zheng, Xiaoyu; Zhou, Ruhai; Cui, Zhenlu; Zhou, Hong

    2006-01-01

    ... property characterization. The materials considered are nano-rods and nano-clays in aqueous and polymeric solvents, which are flight technology targets for high performance properties ranging from electrical, thermal...

  8. Responsive design high performance

    CERN Document Server

    Els, Dewald

    2015-01-01

    This book is ideal for developers who have experience in developing websites or possess minor knowledge of how responsive websites work. No experience of high-level website development or performance tweaking is required.

  9. High energy astrophysics

    International Nuclear Information System (INIS)

    Engel, A.R.

    1979-01-01

    High energy astrophysical research carried out at the Blackett Laboratory, Imperial College, London is reviewed. Work considered includes cosmic ray particle detection, x-ray astronomy, gamma-ray astronomy, gamma and x-ray bursts. (U.K.)

  10. High-tech entrepreneurship

    DEFF Research Database (Denmark)

    Bernasconi, Michel; Harris, Simon; Mønsted, Mette

    ; entrepreneurial finance; marketing technological innovations; and high-tech incubation management. Including case studies to give practical insights into genuine business examples, this comprehensive book has a distinctly 'real-world' focus throughout.Edited by a multi-national team, this comprehensive book......High-tech businesses form a crucial part of entrepreneurial activity - in some ways representing very typical examples of entrepreneurship, yet in some ways representing quite different challenges. The uncertainty in innovation and advanced technology makes it difficult to use conventional economic...... focuses on the blend of theory and practice needed to inform advanced entrepreneurship students of the specifics of high-tech start-ups. Key topics covered include: uncertainty and innovation; entrepreneurial finance; marketing technological innovations; and high-tech incubation management...

  11. Physics and high technology

    International Nuclear Information System (INIS)

    Shao Liqin; Ma Junru.

    1992-01-01

    At present, the development of high technology has opened a new chapter in world's history of science and technology. This review describes the great impact of physics on high technology in six different fields (energy technology, new materials, information technology, biotechnology, space technology, and Ocean technology). It is shown that the new concepts and new methods created in physics and the special conditions and measurements established for physics researches not only deepen human's knowledge about nature but also point out new directions for engineering and technology. The achievements in physics have been more and more applied to high technology, while the development of high technology has explored some new research areas and raised many novel, important projects for physics. Therefore, it is important for us to strengthen the research on these major problems in physics

  12. High Velocity Gas Gun

    Science.gov (United States)

    1988-01-01

    A video tape related to orbital debris research is presented. The video tape covers the process of loading a High Velocity Gas Gun and firing it into a mounted metal plate. The process is then repeated in slow motion.

  13. Hyperglycemia (High Blood Glucose)

    Medline Plus

    Full Text Available ... and Learning About Prediabetes Type 2 Diabetes Risk Test Lower Your Risk Healthy Eating Overweight Smoking High ... You at Risk? Diagnosis Lower Your Risk Risk Test Alert Day Prediabetes My Health Advisor Tools to ...

  14. Hyperglycemia (High Blood Glucose)

    Medline Plus

    Full Text Available ... Type 2 About Us Online Community Meal Planning Sign In Search: Search More Sites Search ≡ Are You ... m.). What are the Symptoms of Hyperglycemia? The signs and symptoms include the following: High blood glucose ...

  15. High Plains Aquifer

    Data.gov (United States)

    Kansas Data Access and Support Center — These digital maps contain information on the altitude of the base, the extent, and the 1991 potentiometric surface (i.e. altitude of the water table) of the High...

  16. High Blood Pressure

    Science.gov (United States)

    ... can help you control high blood pressure. These habits include: Healthy eating Being physically active Maintaining a healthy weight Limiting alcohol intake Managing and coping with stress To help make lifelong lifestyle changes, try making ...

  17. Hyperglycemia (High Blood Glucose)

    Medline Plus

    Full Text Available ... and eAG Hypoglycemia (Low blood glucose) Hyperglycemia (High blood glucose) Dawn Phenomenon Checking for Ketones Tight Diabetes Control donate en -- A Future Without Diabetes - a-future- ...

  18. Very high multiplicity physics

    CERN Document Server

    Mandjavidze, I D

    2001-01-01

    The status of the programme of studying processes with high multiplicity, when inelasticity is close to unity, is considered. The definition of the processes under study is given, and the motivation of investigations and the experimentally observed predictions are discussed

  19. Hyperglycemia (High Blood Glucose)

    Medline Plus

    Full Text Available ... Blood Pressure Physical Activity High Blood Glucose My Health Advisor Tools To Know Your Risk Alert Day ... DKA (Ketoacidosis) & Ketones Kidney Disease (Nephropathy) Gastroparesis Mental Health Step On Up Treatment & Care Blood Glucose Testing ...

  20. High Resolution Elevation Contours

    Data.gov (United States)

    Minnesota Department of Natural Resources — This dataset contains contours generated from high resolution data sources such as LiDAR. Generally speaking this data is 2 foot or less contour interval.

  1. Hypertension (High Blood Pressure)

    Science.gov (United States)

    ... Add less salt to your food and avoid fast food and other foods that are high in salt. Know your blood pressure and have it ... a Health Problem Cholesterol Smart Snacking Yoga for Stress Relief ...

  2. Hyperglycemia (High Blood Glucose)

    Medline Plus

    Full Text Available ... such as family conflicts or school or dating problems. You may have experienced the dawn phenomenon (a ... high blood glucose early will help you avoid problems associated with hyperglycemia. How Do I Treat Hyperglycemia? ...

  3. HIGH-ALTITUDE ILLNESS

    Directory of Open Access Journals (Sweden)

    Dwitya Elvira

    2015-05-01

    Full Text Available AbstrakHigh-altitude illness (HAI merupakan sekumpulan gejala paru dan otak yang terjadi pada orang yang baru pertama kali mendaki ke ketinggian. HAI terdiri dari acute mountain sickness (AMS, high-altitude cerebral edema (HACE dan high-altitude pulmonary edema (HAPE. Tujuan tinjauan pustaka ini adalah agar dokter dan wisatawan memahami risiko, tanda, gejala, dan pengobatan high-altitude illness. Perhatian banyak diberikan terhadap penyakit ini seiring dengan meningkatnya popularitas olahraga ekstrim (mendaki gunung tinggi, ski dan snowboarding dan adanya kemudahan serta ketersediaan perjalanan sehingga jutaan orang dapat terpapar bahaya HAI. Di Pherice, Nepal (ketinggian 4343 m, 43% pendaki mengalami gejala AMS. Pada studi yang dilakukan pada tempat wisata di resort ski Colorado, Honigman menggambarkan kejadian AMS 22% pada ketinggian 1850 m sampai 2750 m, sementara Dean menunjukkan 42% memiliki gejala pada ketinggian 3000 m. Aklimatisasi merupakan salah satu tindakan pencegahan yang dapat dilakukan sebelum pendakian, selain beberapa pengobatan seperti asetazolamid, dexamethasone, phosopodiestrase inhibitor, dan ginko biloba.Kata kunci: high-altitude illness, acute mountain sickness, edema cerebral, pulmonary edema AbstractHigh-altitude illness (HAI is symptoms of lung and brain that occurs in people who first climb to altitude. HAI includes acute mountain sickness (AMS, high-altitude cerebral edema (HACE and high altitude pulmonary edema (HAPE. The objective of this review was to understand the risks, signs, symptoms, and treatment of high-altitude illness. The attention was given to this disease due to the rising popularity of extreme sports (high mountain climbing, skiing and snowboarding and the ease and availability of the current travelling, almost each year, millions of people could be exposed to the danger of HAI. In Pherice, Nepal (altitude 4343 m, 43% of climbers have symptoms of AMS. Furthermore, in a study conducted at sites in

  4. High-pressure tritium

    International Nuclear Information System (INIS)

    Coffin, D.O.

    1976-01-01

    Some solutions to problems of compressing and containing tritium gas to 200 MPa at 700 0 K are discussed. The principal emphasis is on commercial compressors and high-pressure equipment that can be easily modified by the researcher for safe use with tritium. Experience with metal bellows and diaphragm compressors has been favorable. Selection of materials, fittings, and gauges for high-pressure tritium work is also reviewed briefly

  5. High speed heterostructure devices

    CERN Document Server

    Beer, Albert C; Willardson, R K; Kiehl, Richard A; Sollner, T C L Gerhard

    1994-01-01

    Volume 41 includes an in-depth review of the most important, high-speed switches made with heterojunction technology. This volume is aimed at the graduate student or working researcher who needs a broad overview andan introduction to current literature. Key Features * The first complete review of InP-based HFETs and complementary HFETs, which promise very low power and high speed * Offers a complete, three-chapter review of resonant tunneling * Provides an emphasis on circuits as well as devices.

  6. High performance polymeric foams

    International Nuclear Information System (INIS)

    Gargiulo, M.; Sorrentino, L.; Iannace, S.

    2008-01-01

    The aim of this work was to investigate the foamability of high-performance polymers (polyethersulfone, polyphenylsulfone, polyetherimide and polyethylenenaphtalate). Two different methods have been used to prepare the foam samples: high temperature expansion and two-stage batch process. The effects of processing parameters (saturation time and pressure, foaming temperature) on the densities and microcellular structures of these foams were analyzed by using scanning electron microscopy

  7. High Performance Concrete

    Directory of Open Access Journals (Sweden)

    Traian Oneţ

    2009-01-01

    Full Text Available The paper presents the last studies and researches accomplished in Cluj-Napoca related to high performance concrete, high strength concrete and self compacting concrete. The purpose of this paper is to raid upon the advantages and inconveniences when a particular concrete type is used. Two concrete recipes are presented, namely for the concrete used in rigid pavement for roads and another one for self-compacting concrete.

  8. High energy positron imaging

    International Nuclear Information System (INIS)

    Chen Shengzu

    2003-01-01

    The technique of High Energy Positron Imaging (HEPI) is the new development and extension of Positron Emission Tomography (PET). It consists of High Energy Collimation Imaging (HECI), Dual Head Coincidence Detection Imaging (DHCDI) and Positron Emission Tomography (PET). We describe the history of the development and the basic principle of the imaging methods of HEPI in details in this paper. Finally, the new technique of the imaging fusion, which combined the anatomical image and the functional image together are also introduced briefly

  9. High-temperature sensor

    Science.gov (United States)

    Not Available

    1981-01-29

    A high temperature sensor is described which includes a pair of electrical conductors separated by a mass of electrical insulating material. The insulating material has a measurable resistivity within the sensor that changes in relation to the temperature of the insulating material within a high temperature range (1000 to 2000/sup 0/K). When required, the sensor can be encased within a ceramic protective coating.

  10. High temperature pressure gauge

    Science.gov (United States)

    Echtler, J. Paul; Scandrol, Roy O.

    1981-01-01

    A high temperature pressure gauge comprising a pressure gauge positioned in fluid communication with one end of a conduit which has a diaphragm mounted in its other end. The conduit is filled with a low melting metal alloy above the diaphragm for a portion of its length with a high temperature fluid being positioned in the remaining length of the conduit and in the pressure gauge.

  11. Aspirated High Pressure Compressor

    Science.gov (United States)

    2006-08-01

    suggested by the General Electric Company based on an advanced military engine concept intended for high speed flight. The resultant high flight...section, consisting of the two rotors, each on an computed points. The peak pressure ratio is 3.08 and the peak independent, electric motor-driven...instrumentation along Moto . .. ,oto2 with the test error analysis were given by Onnee [14). SFlywheel 2 BLOWDOWN OPERATION T--’..Exit-t-rottle

  12. High Caloric Diet for ALS Patients: High Fat, High Carbohydrate or High Protein

    Directory of Open Access Journals (Sweden)

    Sarvin Sanaie

    2015-01-01

    Full Text Available ALS is a fatal motor neurodegenerative disease characterized by muscle atrophy and weakness, dysarthria, and dysphagia. The mean survival of ALS patients is three to five years, with 50% of those diagnosed dying within three years of onset (1. A multidisciplinary approach is crucial to set an appropriate plan for metabolic and nutritional support in ALS. Nutritional management incorporates a continuous assessment and implementation of dietary modifications throughout the duration of the disease. The nutritional and metabolic approaches to ALS should start when the diagnosis of ALS is made and should become an integral part of the continuous care to the patient, including nutritional surveillance, dietary counseling, management of dysphagia, and enteral nutrition when needed. Malnutrition and lean body mass loss are frequent findings in ALS patients necessitating comprehensive energy requirement assessment for these patients. Malnutrition is an independent prognostic factor for survival in ALS with a 7.7 fold increase in risk of death. Malnutrition is estimated to develop in one quarter to half of people with ALS (2. Adequate calorie and protein provision would diminish muscle loss in this vulnerable group of patients. Although appropriate amount of energy to be administered is yet to be established, high calorie diet is expected to be effective for potential improvement of survival; ALS patients do not normally receive adequate  intake of energy. A growing number of clinicians suspect that a high calorie diet implemented early in their disease may help people with ALS meet their increased energy needs and extend their survival. Certain high calorie supplements appear to be safe and well tolerated by people with ALS according to studies led by Universitäts klinikum Ulm's and, appear to stabilize body weight within 3 months. In a recent study by Wills et al., intake of high-carbohydrate low-fat supplements has been recommended in ALS patients (3

  13. High availability using virtualization

    International Nuclear Information System (INIS)

    Calzolari, Federico; Arezzini, Silvia; Ciampa, Alberto; Mazzoni, Enrico; Domenici, Andrea; Vaglini, Gigliola

    2010-01-01

    High availability has always been one of the main problems for a data center. Till now high availability was achieved by host per host redundancy, a highly expensive method in terms of hardware and human costs. A new approach to the problem can be offered by virtualization. Using virtualization, it is possible to achieve a redundancy system for all the services running on a data center. This new approach to high availability allows the running virtual machines to be distributed over a small number of servers, by exploiting the features of the virtualization layer: start, stop and move virtual machines between physical hosts. The 3RC system is based on a finite state machine, providing the possibility to restart each virtual machine over any physical host, or reinstall it from scratch. A complete infrastructure has been developed to install operating system and middleware in a few minutes. To virtualize the main servers of a data center, a new procedure has been developed to migrate physical to virtual hosts. The whole Grid data center SNS-PISA is running at the moment in virtual environment under the high availability system.

  14. High temperature storage loop :

    Energy Technology Data Exchange (ETDEWEB)

    Gill, David Dennis; Kolb, William J.

    2013-07-01

    A three year plan for thermal energy storage (TES) research was created at Sandia National Laboratories in the spring of 2012. This plan included a strategic goal of providing test capability for Sandia and for the nation in which to evaluate high temperature storage (>650ÀC) technology. The plan was to scope, design, and build a flow loop that would be compatible with a multitude of high temperature heat transfer/storage fluids. The High Temperature Storage Loop (HTSL) would be reconfigurable so that it was useful for not only storage testing, but also for high temperature receiver testing and high efficiency power cycle testing as well. In that way, HTSL was part of a much larger strategy for Sandia to provide a research and testing platform that would be integral for the evaluation of individual technologies funded under the SunShot program. DOEs SunShot program seeks to reduce the price of solar technologies to 6/kWhr to be cost competitive with carbon-based fuels. The HTSL project sought to provide evaluation capability for these SunShot supported technologies. This report includes the scoping, design, and budgetary costing aspects of this effort

  15. High availability using virtualization

    Science.gov (United States)

    Calzolari, Federico

    2009-10-01

    High availability has always been one of the main problems for a data center. Till now high availability was achieved by host per host redundancy, a highly expensive method in terms of hardware and human costs. A new approach to the problem can be offered by virtualization. Using virtualization, it is possible to achieve a redundancy system for all the services running on a data center. This new approach to high availability allows to share the running virtual machines over the servers up and running, by exploiting the features of the virtualization layer: start, stop and move virtual machines between physical hosts. The system (3RC) is based on a finite state machine with hysteresis, providing the possibility to restart each virtual machine over any physical host, or reinstall it from scratch. A complete infrastructure has been developed to install operating system and middleware in a few minutes. To virtualize the main servers of a data center, a new procedure has been developed to migrate physical to virtual hosts. The whole Grid data center SNS-PISA is running at the moment in virtual environment under the high availability system. As extension of the 3RC architecture, several storage solutions have been tested to store and centralize all the virtual disks, from NAS to SAN, to grant data safety and access from everywhere. Exploiting virtualization and ability to automatically reinstall a host, we provide a sort of host on-demand, where the action on a virtual machine is performed only when a disaster occurs.

  16. High Altitude and Heart

    Directory of Open Access Journals (Sweden)

    Murat Yalcin

    2011-04-01

    Full Text Available Nowadays, situations associated with high altitude such as mountaineering, aviation increasingly draw the attention of people. Gas pressure decreases and hypoxia is encountered when climbing higher. Physiological and pathological responses of human body to different heights are different. Therefore, physiological and pathological changes that may occur together with height and to know the clinical outcomes of these are important . Acute mountain sickness caused by high altitude and high altitude cerebral edema are preventable diseases with appropriate precautions. Atmospheric oxygen decreasing with height, initiates many adaptive mechanisms. These adaptation mechanisms and acclimatization vary widely among individuals because of reasons such as environmental factors, exercise and cold. High altitude causes different changes in the cardiovascular system with various mechanisms. Although normal individuals easily adapt to these changes, this situation can lead to undesirable results in people with heart disease. For this reason, it should be known the effective evaluation of the people with known heart disease before traveling to high altitude and the complications due to the changes with height and the recommendations can be made to these patients. [TAF Prev Med Bull 2011; 10(2.000: 211-222

  17. Clustering high dimensional data

    DEFF Research Database (Denmark)

    Assent, Ira

    2012-01-01

    for clustering are required. Consequently, recent research has focused on developing techniques and clustering algorithms specifically for high-dimensional data. Still, open research issues remain. Clustering is a data mining task devoted to the automatic grouping of data based on mutual similarity. Each cluster......High-dimensional data, i.e., data described by a large number of attributes, pose specific challenges to clustering. The so-called ‘curse of dimensionality’, coined originally to describe the general increase in complexity of various computational problems as dimensionality increases, is known...... that provide different cluster models and different algorithmic approaches for cluster detection. Common to all approaches is the fact that they require some underlying assessment of similarity between data objects. In this article, we provide an overview of the effects of high-dimensional spaces...

  18. High-energy detector

    Science.gov (United States)

    Bolotnikov, Aleksey E [South Setauket, NY; Camarda, Giuseppe [Farmingville, NY; Cui, Yonggang [Upton, NY; James, Ralph B [Ridge, NY

    2011-11-22

    The preferred embodiments are directed to a high-energy detector that is electrically shielded using an anode, a cathode, and a conducting shield to substantially reduce or eliminate electrically unshielded area. The anode and the cathode are disposed at opposite ends of the detector and the conducting shield substantially surrounds at least a portion of the longitudinal surface of the detector. The conducting shield extends longitudinally to the anode end of the detector and substantially surrounds at least a portion of the detector. Signals read from one or more of the anode, cathode, and conducting shield can be used to determine the number of electrons that are liberated as a result of high-energy particles impinge on the detector. A correction technique can be implemented to correct for liberated electron that become trapped to improve the energy resolution of the high-energy detectors disclosed herein.

  19. Theoretical high energy physics

    International Nuclear Information System (INIS)

    Lee, T.D.

    1993-01-01

    Brief reports are given on the work of several professors. The following areas are included: quantum chromodynamics calculations using numerical lattice gauge theory and a high-speed parallel computer; the ''spin wave'' description of bosonic particles moving on a lattice with same-site exclusion; a high-temperature expansion to 13th order for the O(4)-symmetric φ 4 model on a four-dimensional F 4 lattice; spin waves and lattice bosons; superconductivity of C 60 ; meson-meson interferometry in heavy-ion collisions; baryon number violation in the Standard Model in high-energy collisions; hard thermal loops in QCD; electromagnetic interactions of anyons; the relation between Bose-Einstein and BCS condensations; Euclidean wormholes with topology S 1 x S 2 x R; vacuum decay and symmetry breaking by radiative corrections; inflationary solutions to the cosmological horizon and flatness problems; and magnetically charged black holes

  20. High resolution data acquisition

    Science.gov (United States)

    Thornton, G.W.; Fuller, K.R.

    1993-04-06

    A high resolution event interval timing system measures short time intervals such as occur in high energy physics or laser ranging. Timing is provided from a clock, pulse train, and analog circuitry for generating a triangular wave synchronously with the pulse train (as seen in diagram on patent). The triangular wave has an amplitude and slope functionally related to the time elapsed during each clock pulse in the train. A converter forms a first digital value of the amplitude and slope of the triangle wave at the start of the event interval and a second digital value of the amplitude and slope of the triangle wave at the end of the event interval. A counter counts the clock pulse train during the interval to form a gross event interval time. A computer then combines the gross event interval time and the first and second digital values to output a high resolution value for the event interval.

  1. High voltage power supply

    Science.gov (United States)

    Ruitberg, A. P.; Young, K. M. (Inventor)

    1985-01-01

    A high voltage power supply is formed by three discrete circuits energized by a battery to provide a plurality of concurrent output signals floating at a high output voltage on the order of several tens of kilovolts. In the first two circuits, the regulator stages are pulse width modulated and include adjustable ressistances for varying the duty cycles of pulse trains provided to corresponding oscillator stages while the third regulator stage includes an adjustable resistance for varying the amplitude of a steady signal provided to a third oscillator stage. In the first circuit, the oscillator, formed by a constant current drive network and a tuned resonant network included a step up transformer, is coupled to a second step up transformer which, in turn, supplies an amplified sinusoidal signal to a parallel pair of complementary poled rectifying, voltage multiplier stages to generate the high output voltage.

  2. High brightness electron accelerator

    International Nuclear Information System (INIS)

    Sheffield, R.L.; Carlsten, B.E.; Young, L.M.

    1994-01-01

    A compact high brightness linear accelerator is provided for use, e.g., in a free electron laser. The accelerator has a first plurality of accelerating cavities having end walls with four coupling slots for accelerating electrons to high velocities in the absence of quadrupole fields. A second plurality of cavities receives the high velocity electrons for further acceleration, where each of the second cavities has end walls with two coupling slots for acceleration in the absence of dipole fields. The accelerator also includes a first cavity with an extended length to provide for phase matching the electron beam along the accelerating cavities. A solenoid is provided about the photocathode that emits the electrons, where the solenoid is configured to provide a substantially uniform magnetic field over the photocathode surface to minimize emittance of the electrons as the electrons enter the first cavity. 5 figs

  3. High-tech entrepreneurship

    DEFF Research Database (Denmark)

    Bernasconi, Michel; Harris, Simon; Mønsted, Mette

    High-tech businesses form a crucial part of entrepreneurial activity - in some ways representing very typical examples of entrepreneurship, yet in some ways representing quite different challenges. The uncertainty in innovation and advanced technology makes it difficult to use conventional economic......; entrepreneurial finance; marketing technological innovations; and high-tech incubation management. Including case studies to give practical insights into genuine business examples, this comprehensive book has a distinctly 'real-world' focus throughout.Edited by a multi-national team, this comprehensive book...... planning models, and also means that the management skills used in this area must be more responsive to issues of risk, uncertainty and evaluation than in conventional business opportunities. Whilst entrepreneurial courses do reflect the importance of high-tech businesses, they often lack the resources...

  4. High-pressure crystallography.

    Science.gov (United States)

    McMahon, Malcolm I

    2012-01-01

    The ability of pressure to change inter-atomic distances strongly leads to a wide range of pressure-induced phenomena at high pressures: for example metallisation, amorphisation, superconductivity and polymerisation. Key to understanding these phenomena is the determination of the crystal structure using x-ray or neutron diffraction. The tools necessary to compress matter above 1 million atmospheres (1 Megabar or 100 GPa) were established by the mid 1970s, but it is only since the early 1990s that we have been able to determine the detailed crystal structures of materials at such pressures. In this chapter I briefly review the history of high-pressure crystallography, and describe the techniques used to obtain and study materials at high pressure. Recent crystallographic studies of elements are then used to illustrate what is now possible using modern detectors and synchrotron sources. Finally, I speculate as to what crystallographic studies might become possible over the next decade.

  5. High performance homes

    DEFF Research Database (Denmark)

    Beim, Anne; Vibæk, Kasper Sánchez

    2014-01-01

    Can prefabrication contribute to the development of high performance homes? To answer this question, this chapter defines high performance in more broadly inclusive terms, acknowledging the technical, architectural, social and economic conditions under which energy consumption and production occur....... Consideration of all these factors is a precondition for a truly integrated practice and as this chapter demonstrates, innovative project delivery methods founded on the manufacturing of prefabricated buildings contribute to the production of high performance homes that are cost effective to construct, energy...... efficient to operate and valuable for building communities. Herein discussed are two successful examples of low energy prefabricated housing projects built in Copenhagen Denmark, which embraced both the constraints and possibilities offered by prefabrication....

  6. High energy radiation detector

    International Nuclear Information System (INIS)

    Vosburgh, K.G.

    1975-01-01

    The high energy radiation detector described comprises a set of closely spaced wedge reflectors. Each wedge reflector is composed of three sides forming identical isoceles triangles with a common apex and an open base forming an equilateral triangle. The length of one side of the base is less than the thickness of the coat of material sensitive to high energy radiation. The wedge reflectors reflect the light photons spreading to the rear of the coat in such a way that each reflected track is parallel to the incident track of the light photon spreading rearwards. The angle of the three isosceles triangles with a common apex is between 85 and 95 deg. The first main surface of the coat of high energy radiation sensitive material is in contact with the projecting edges of the surface of the wedge reflectors of the reflecting element [fr

  7. JUNOS High Availability

    CERN Document Server

    Sonderegger, James; Milne, Kieran; Palislamovic, Senad

    2009-01-01

    Whether your network is a complex carrier or just a few machines supporting a small enterprise, JUNOS High Availability will help you build reliable and resilient networks that include Juniper Networks devices. With this book's valuable advice on software upgrades, scalability, remote network monitoring and management, high-availability protocols such as VRRP, and more, you'll have your network uptime at the five, six, or even seven nines -- or 99.99999% of the time. Rather than focus on "greenfield" designs, the authors explain how to intelligently modify multi-vendor networks. You'll learn

  8. High Pressure Biomass Gasification

    Energy Technology Data Exchange (ETDEWEB)

    Agrawal, Pradeep K [Georgia Tech Research Corporation, Atlanta, GA (United States)

    2016-07-29

    According to the Billion Ton Report, the U.S. has a large supply of biomass available that can supplement fossil fuels for producing chemicals and transportation fuels. Agricultural waste, forest residue, and energy crops offer potential benefits: renewable feedstock, zero to low CO2 emissions depending on the specific source, and domestic supply availability. Biomass can be converted into chemicals and fuels using one of several approaches: (i) biological platform converts corn into ethanol by using depolymerization of cellulose to form sugars followed by fermentation, (ii) low-temperature pyrolysis to obtain bio-oils which must be treated to reduce oxygen content via HDO hydrodeoxygenation), and (iii) high temperature pyrolysis to produce syngas (CO + H2). This last approach consists of producing syngas using the thermal platform which can be used to produce a variety of chemicals and fuels. The goal of this project was to develop an improved understanding of the gasification of biomass at high pressure conditions and how various gasification parameters might affect the gasification behavior. Since most downstream applications of synags conversion (e.g., alcohol synthesis, Fischer-Tropsch synthesis etc) involve utilizing high pressure catalytic processes, there is an interest in carrying out the biomass gasification at high pressure which can potentially reduce the gasifier size and subsequent downstream cleaning processes. It is traditionally accepted that high pressure should increase the gasification rates (kinetic effect). There is also precedence from coal gasification literature from the 1970s that high pressure gasification would be a beneficial route to consider. Traditional approach of using thermogravimetric analyzer (TGA) or high-pressure themogravimetric analyzer (PTGA) worked well in understanding the gasification kinetics of coal gasification which was useful in designing high pressure coal gasification processes. However

  9. High availability IT services

    CERN Document Server

    Critchley, Terry

    2014-01-01

    This book starts with the basic premise that a service is comprised of the 3Ps-products, processes, and people. Moreover, these entities and their sub-entities interlink to support the services that end users require to run and support a business. This widens the scope of any availability design far beyond hardware and software. It also increases the potential for service failure for reasons beyond just hardware and software; the concept of logical outages. High Availability IT Services details the considerations for designing and running highly available ""services"" and not just the systems

  10. High-level verification

    CERN Document Server

    Lerner, Sorin; Kundu, Sudipta

    2011-01-01

    Given the growing size and heterogeneity of Systems on Chip (SOC), the design process from initial specification to chip fabrication has become increasingly complex. This growing complexity provides incentive for designers to use high-level languages such as C, SystemC, and SystemVerilog for system-level design. While a major goal of these high-level languages is to enable verification at a higher level of abstraction, allowing early exploration of system-level designs, the focus so far for validation purposes has been on traditional testing techniques such as random testing and scenario-based

  11. High loading uranium plate

    International Nuclear Information System (INIS)

    Wiencek, T.C.; Domagala, R.F.; Thresh, H.R.

    1990-01-01

    Two embodiments of a high uranium fuel plate are disclosed which contain a meat comprising structured uranium compound confined between a pari of diffusion bonded ductile metal cladding plates uniformly covering the meat, the meat hiving a uniform high fuel loading comprising a content of uranium compound greater than about 45 Vol. % at a porosity not greater than about 10 Vol. %. In a first embodiment, the meat is a plurality of parallel wires of uranium compound. In a second embodiment, the meat is a dispersion compact containing uranium compound. The fuel plates are fabricated by a hot isostatic pressing process

  12. High-pressure apparatus

    OpenAIRE

    Schepdael, van, L.J.M.; Bartels, P.V.; Berg, van den, R.W.

    1999-01-01

    The invention relates to a high-pressure device (1) having a cylindrical high-pressure vessel (3) and prestressing means in order to exert an axial pressure on the vessel. The vessel (3) can have been formed from a number of layers of composite material, such as glass, carbon or aramide fibers which are oriented in the peripheral direction and are embedded in a matrix of epoxy resin or polyurethane. By applying the axial prestress to the pressure vessel (3), the tangential stress is distribut...

  13. Theoretical high energy physics

    International Nuclear Information System (INIS)

    Lee, T.D.

    1991-01-01

    This report discusses theoretical research in high energy physics at Columbia University. Some of the research topics discussed are: quantum chromodynamics with dynamical fermions; lattice gauge theory; scattering of neutrinos by photons; atomic physics constraints on the properties of ultralight-ultraweak gauge bosons; black holes; Chern- Simons physics; S-channel theory of superconductivity; charged boson system; gluon-gluon interactions; high energy scattering in the presence of instantons; anyon physics; causality constraints on primordial magnetic manopoles; charged black holes with scalar hair; properties of Chern-Aimona-Higgs solitons; and extended inflationary universe

  14. CT Measurement of Range of Motion of Ankle and Subtalar Joints Following Two Lateral Column Lengthening Procedures

    NARCIS (Netherlands)

    Beimers, Lijkele; Louwerens, Jan W. K.; Tuijthof, Gabrielle Josephine Maria; Jonges, Remmet; van Dijk, C. N. Niek; Blankevoort, Leendert

    2012-01-01

    Background: Lateral column lengthening (LCL) has become an accepted procedure for the operative treatment of the flexible flatfoot deformity. Hindfoot arthrodesis via a calcaneocuboid distraction arthrodesis (CCDA) has been considered a less favourable surgical option than the anterior open wedge

  15. High School Principals and the High School Journalism Program.

    Science.gov (United States)

    Peterson, Jane W.

    A study asked selected high school principals to respond to statements about the value of high school journalism to the high school student and about the rights and responsibilities of the high school journalist. These responses were then checked against such information as whether or not the high school principal had worked on a high school…

  16. Theoretical high energy physics

    International Nuclear Information System (INIS)

    Lee, T.D.

    1992-01-01

    This progress report discusses research by Columbia University staff in high energy physics. Some of the topics discussed are as follows: lattice gauge theory; quantum chromodynamics; parity doublets; solitons; baryon number violation; black holes; magnetic monopoles; gluon plasma; Chern-Simons theory; and the inflationary universe

  17. High surface area calcite

    Science.gov (United States)

    Schultz, L. N.; Andersson, M. P.; Dalby, K. N.; Müter, D.; Okhrimenko, D. V.; Fordsmand, H.; Stipp, S. L. S.

    2013-05-01

    Calcite (CaCO3) is important in many fields—in nature, because it is a component of aquifers, oil reservoirs and prospective CO2 storage sites, and in industry, where it is used in products as diverse as paper, toothpaste, paint, plastic and aspirin. It is difficult to obtain high purity calcite with a high surface area but such material is necessary for industrial applications and for fundamental calcite research. Commercial powder is nearly always contaminated with growth inhibitors such as sugars, citrate or pectin and most laboratory synthesis methods deliver large precipitates, often containing vaterite or aragonite. To address this problem, we (i) adapted the method of carbonating a Ca(OH)2 slurry with CO2 gas to develop the first simple, cheap, safe and reproducible procedure using common laboratory equipment, to obtain calcite that reproducibly had a surface area of 14-17 m2/g and (ii) conducted a thorough characterization of the product. Scanning electron microscopy (SEM) revealed nanometer scale, rhombohedral crystals. X-ray diffraction (XRD), X-ray photoelectron spectroscopy (XPS) and infrared spectroscopy (IR) confirmed highly crystalline, pure calcite that more closely resembles the dimensions of the biogenic calcite produced by algae in coccoliths than other methods for synthesizing calcite. We suggest that this calcite is useful when purity and high surface area are important.

  18. High Density Matter

    Directory of Open Access Journals (Sweden)

    Stone J.R.

    2013-12-01

    Full Text Available The microscopic composition and properties of matter at super-saturation densities have been the subject of intense investigation for decades. The scarcity of experimental and observational data has led to the necessary reliance on theoretical models. There remains great uncertainty in these models which, of necessity, have to go beyond the over-simple assumption that high density matter consists only of nucleons and leptons. Heavy strange baryons, mesons and quark matter in different forms and phases have to be included to fulfil basic requirements of fundamental laws of physics. In this contribution latest developments in construction of the Equation of State (EoS of high-density matter at zero and finite temperature assuming different composition of matter will be discussed. Critical comparison of model EoS with available experimental data from heavy ion collisions and observations on neutron stars, including gravitational mass, radii and cooling patterns and data on X-ray burst sources and low mass X-ray binaries are made. Fundamental differences between the EoS of low-density, high temperature matter, such as is created in heavy ion collisions and of high-density, low temperature compact objects is discussed.

  19. High voltage electrical injuries

    International Nuclear Information System (INIS)

    Janjua, S.A.

    2002-01-01

    Objective: To highlight the devastating nature and consequences of high voltage electrical injuries and to stress the need for its prevention. Design: It was a retrospective study. Place and duration of study: The study was conducted at Army Burn Centre, Combined Military Hospital Kharian Cantonment, between January 1,1998 to December 31, 2000. Subjects and Methods: All the patients reporting to Army Burn Centre with high voltage electrical injuries were included in the study. The epidemiology of these injuries were studied along with the pattern of their management and outcome in terms of mortality and morbidity. Results: Of all the patients admitted to the Army Burn Center, 5.94% were affected with electrical injuries. They were predominantly males in a ratio of 9.75:1 and mostly in the 3rd and 4th decades of their lives. Seventy percent of these injuries were injuries were work-related and 75% had associated surface burns. There was significant mortality rate of 18.6% and a limb amputation rate of 80% along with professional disability rate of 91% rendering it a highly morbid condition. Conclusion: This study stresses the necessity to educate the general public with regard to the devastating nature of high voltage electrical injury and highlight the importance of prevention. (author)

  20. Hyperglycemia (High Blood Glucose)

    Medline Plus

    Full Text Available ... Monthly In Memory In Honor Become a Member En Español Type 1 Type 2 About Us Online ... Print Page Text Size: A A A Listen En Español Hyperglycemia (High Blood Glucose) Hyperglycemia is the ...

  1. High Energy Materials

    Indian Academy of Sciences (India)

    IAS Admin

    Propellants used in rockets, pyrotechnics used in festivities, explosives used for military purposes, blasting chemicals used in construction activities, etc., are high energy materials. There is a lot of fascinating chemistry and interesting history behind them. This article gives an overview of these aspects, with somewhat more ...

  2. High speed preprocessing system

    Indian Academy of Sciences (India)

    system. The hardware used came in three PCBs of standard double Euro card of size of. 233.4 mm 220 mm excluding the motherboard. The system has passed all MIL-STD qualification tests as below: * Low temperature test: À30 C for duration 16 h and last one hour operational. * High temperature test: ‡55 C for duration ...

  3. High Energy Materials

    Indian Academy of Sciences (India)

    IAS Admin

    Propellants used in rockets, pyrotechnics used in festivities, explosives used for ... working of rockets, and the chemistry of fireworks. 1. Introduction. High energy materials are compounds which store chemical energy. They are either single compounds like trinitrotoluene. (TNT) containing .... ets stabilized by bamboo sticks.

  4. Fascination at high pressures

    International Nuclear Information System (INIS)

    Chidambaram, R.

    1992-01-01

    Research at high pressures has developed into an interdisciplinary area which has important implications for and applications in the areas of physics, chemistry, materials sciences, planetary sciences, biology, engineering sciences and technology. The state of-the-art in this field is reviewed and future directions are indicated. (M.G.B.)

  5. Investing in High School

    Science.gov (United States)

    Green, Daniel G.

    2012-01-01

    Strapped for cash, a Massachusetts high school creates its own venture capital fund to incentivize teachers to create programs that improve student learning. The result has been higher test scores and higher job satisfaction. One important program is credited with helping close the achievement gap at the school, while others have helped ambitious…

  6. CSTI High Capacity Power

    International Nuclear Information System (INIS)

    Winter, J.M.

    1989-01-01

    The SP-100 program was established in 1983 by DOD, DOE, and NASA as a joint program to develop the technology necessary for space nuclear power systems for military and civil application. During FY-86 and 87, the NASA SP-100 Advanced Technology Program was devised to maintain the momentum of promising technology advancement efforts started during Phase 1 of SP-100 and to strengthen, in key areas, the chances for successful development and growth capability of space nuclear reactor power systems for future space applications. In FY-88, the Advanced Technology Program was incorporated into NASA's new Civil Space Technology Initiative (CSTI). The CSTI Program was established to provide the foundation for technology development in automation and robotics, information, propulsion, and power. The CSTI High Capacity Power Program builds on the technology efforts of the SP-100 program, incorporates the previous NASA SP-100 Advanced Technology project, and provides a bridge to NASA Project Pathfinder. The elements of CSTI High Capacity Power development include Conversion Systems, Thermal Management, Power Management, System Diagnostics, and Environmental Interactions. Technology advancement in all areas, including materials, is required to assure the high reliability and 7 to 10 year lifetime demanded for future space nuclear power systems. The overall program will develop and demonstrate the technology base required to provide a wide range of modular power systems as well as allowing mission independence from solar and orbital attitude requirements. Several recent advancements in CSTI High Capacity power development will be discussed

  7. high-poverty schools

    African Journals Online (AJOL)

    leadership in high-poverty schools? Investigations conducted at six successful ..... (not only motivate) others, to build team spirit and pride, and to seek and explore every possible opportunity, source and ..... The key ingredients of school success appear to'be the principal's passion for upliftment, the teachers' commitment ...

  8. Danish High Performance Concretes

    DEFF Research Database (Denmark)

    Nielsen, M. P.; Christoffersen, J.; Frederiksen, J.

    1994-01-01

    In this paper the main results obtained in the research program High Performance Concretes in the 90's are presented. This program was financed by the Danish government and was carried out in cooperation between The Technical University of Denmark, several private companies, and Aalborg University...

  9. Ghana's high forests

    NARCIS (Netherlands)

    Oduro, K.A.

    2016-01-01

    Deforestation and forest degradation in the tropics have been receiving both scientific and political attention in recent decades due to its impacts on the environment and on human livelihoods. In Ghana, the continuous decline of forest resources and the high demand for timber have raised

  10. High Brightness OLED Lighting

    Energy Technology Data Exchange (ETDEWEB)

    Spindler, Jeffrey [OLEDWorks LLC; Kondakova, Marina [OLEDWorks LLC; Boroson, Michael [OLEDWorks LLC; Hamer, John [OLEDWorks LLC

    2016-05-25

    In this work we describe the technology developments behind our current and future generations of high brightness OLED lighting panels. We have developed white and amber OLEDs with excellent performance based on the stacking approach. Current products achieve 40-60 lm/W, while future developments focus on achieving 80 lm/W or higher.

  11. Highly Skilled Migrants

    DEFF Research Database (Denmark)

    Hvidt, Martin

    2016-01-01

    . It is pointed out that while the system facilitated speedy entry to the job market, the lack of inclusion in the Gulf economies of the migrants, the lack of long-term prospects of residing in the countries and the highly asymmetric power balance between sponsor and migrant, provides few incentives...

  12. High-Sensitivity Spectrophotometry.

    Science.gov (United States)

    Harris, T. D.

    1982-01-01

    Selected high-sensitivity spectrophotometric methods are examined, and comparisons are made of their relative strengths and weaknesses and the circumstances for which each can best be applied. Methods include long path cells, noise reduction, laser intracavity absorption, thermocouple calorimetry, photoacoustic methods, and thermo-optical methods.…

  13. Life at High Temperatures

    Indian Academy of Sciences (India)

    Home; Journals; Resonance – Journal of Science Education; Volume 10; Issue 9. Life at High Temperatures. Ramesh Maheshwari. General Article Volume 10 Issue 9 September 2005 pp 23-36. Fulltext. Click here to view fulltext PDF. Permanent link: http://www.ias.ac.in/article/fulltext/reso/010/09/0023-0036. Keywords.

  14. Ghana's high forests

    NARCIS (Netherlands)

    Oduro, K.A.

    2016-01-01

    Deforestation and forest degradation in the tropics have been receiving both scientific and political attention in recent decades due to its impacts on the environment and on human livelihoods. In Ghana, the continuous decline of forest resources and the high demand for timber have raised

  15. High School Book Fairs

    Science.gov (United States)

    Fitzgerald, Marianne

    2006-01-01

    Many secondary students have given up the joy of reading. When asked why they don't read for pleasure, students came up with many different reasons, the first being lack of time. High school students are busy with after school jobs, sports, homework, etc. With the growing number of students enrolled in AP classes, not only is there not much time…

  16. High luminosity particle colliders

    International Nuclear Information System (INIS)

    Palmer, R.B.; Gallardo, J.C.

    1997-03-01

    The authors consider the high energy physics advantages, disadvantages and luminosity requirements of hadron (pp, p anti p), lepton (e + e - , μ + μ - ) and photon-photon colliders. Technical problems in obtaining increased energy in each type of machine are presented. The machines relative size are also discussed

  17. High frequency electromagnetic dosimetry

    CERN Document Server

    Sánchez-Hernández, David A

    2009-01-01

    Along with the growth of RF and microwave technology applications, there is a mounting concern about the possible adverse effects over human health from electromagnetic radiation. Addressing this issue and putting it into perspective, this groundbreaking resource provides critical details on the latest advances in high frequency electromagnetic dosimetry.

  18. Hyperglycemia (High Blood Glucose)

    Medline Plus

    Full Text Available ... In Memory In Honor Become a Member En Español Type 1 Type 2 About Us Online Community ... Page Text Size: A A A Listen En Español Hyperglycemia (High Blood Glucose) Hyperglycemia is the technical ...

  19. High-resolution echocardiography

    Science.gov (United States)

    Nathan, R.

    1979-01-01

    High resolution computer aided ultrasound system provides two-and three-dimensional images of beating heart from many angles. System provides means for determining whether small blood vessels around the heart are blocked or if heart wall is moving normally without interference of dead and noncontracting muscle tissue.

  20. High temperature superconductivity: Proceedings

    International Nuclear Information System (INIS)

    Bedell, K.S.; Coffey, D.; Meltzer, D.E.; Pines, D.; Schrieffer, J.R.

    1990-01-01

    This book is the result of a symposium at Los Alamos in 1989 on High Temperature Superconductivity. The topics covered include: phenomenology, quantum spin liquids, spin space fluctuations in the insulating and metallic phases, normal state properties, and numerical studies and simulations. (JF)

  1. High Temperature Electrolysis

    DEFF Research Database (Denmark)

    Elder, Rachael; Cumming, Denis; Mogensen, Mogens Bjerg

    2015-01-01

    High temperature electrolysis of carbon dioxide, or co-electrolysis of carbon dioxide and steam, has a great potential for carbon dioxide utilisation. A solid oxide electrolysis cell (SOEC), operating between 500 and 900. °C, is used to reduce carbon dioxide to carbon monoxide. If steam is also i...

  2. Rocky Mountain High.

    Science.gov (United States)

    Hill, David

    2001-01-01

    Describes Colorado's Eagle Rock School, which offers troubled teens a fresh start by transporting them to a tuition- free campus high in the mountains. The program encourages spiritual development as well as academic growth. The atmosphere is warm, loving, structured, and nonthreatening. The article profiles several students' experiences at the…

  3. High strength ferritic alloy

    International Nuclear Information System (INIS)

    1977-01-01

    A high strength ferritic steel is specified in which the major alloying elements are chromium and molybdenum, with smaller quantities of niobium, vanadium, silicon, manganese and carbon. The maximum swelling is specified for various irradiation conditions. Rupture strength is also specified. (U.K.)

  4. High Blood Pressure

    Science.gov (United States)

    ... effects on blood pressure. Finding out what genetic patterns contribute to high blood pressure risk. NHLBI-funded researchers identified dozens of ... whether a low-sodium and low-calorie eating pattern, along with aerobic exercise, can improve blood pressure in patients who do not respond to ...

  5. Nuclei in high forms

    International Nuclear Information System (INIS)

    Szymanski, Z.; Berger, J.F.; Heenen, P.H.; Heyde, K.; Haas, B.; Janssens, R.; Paya, D.; Gogny, D.; Huber, G.; Bjoernholm, S.; Brack, M.

    1991-01-01

    The purpose of 1991 Joliot-Curie Summer School is to review the most advances in the understanding of the nuclei physics after the considerable progress in gamma spectroscopy. It covers the following topics: Highly and super-deformed nuclei, nuclear structures, mean-field approach and beyond, fission isomers, nuclear excitations with long lifetime and metal clusters

  6. High Selectivity Oxygen Delignification

    Energy Technology Data Exchange (ETDEWEB)

    Arthur J. Ragauskas

    2005-09-30

    The overall objective of this program was to develop improved extended oxygen delignification (EOD) technologies for current U.S. pulp mill operations. This was accomplished by: (1) Identifying pulping conditions that optimize O and OO performance; (2) Identifying structural features of lignin that enhance reactivity towards EOD of high kappa pulps; (3) Identifying factors minimizing carbohydrate degradation and improve pulp strength of EOD high kappa pulps; (4) Developing a simple, reproducible method of quantifying yield gains from EOD; and (5) Developing process conditions that significantly reduce the capital requirements of EOD while optimizing the yield benefits. Key research outcomes included, demonstrating the use of a mini-O sequence such as (E+O)Dkf:0.05(E+O) or Dkf:0.05(E+O)(E+O) without interstage washing could capture approximately 60% of the delignification efficiency of a conventional O-stage without the major capital requirements associated with an O-stage for conventional SW kraft pulps. The rate of formation and loss of fiber charge during an O-stage stage can be employed to maximize net fiber charge. Optimal fiber charge development and delignification are two independent parameters and do not parallel each other. It is possible to utilize an O-stage to enhance overall cellulosic fiber charge of low and high kappa SW kraft pulps which is beneficial for physical strength properties. The application of NIR and multi-variant analysis was developed into a rapid and simple method of determining the yield of pulp from an oxygen delignification stage that has real-world mill applications. A focus point of this program was the demonstration that Kraft pulping conditions and oxygen delignification of high and low-kappa SW and HW pulps are intimately related. Improved physical pulp properties and yield can be delivered by controlling the H-factor and active alkali charge. Low AA softwood kraft pulp with a kappa number 30 has an average improvement of 2% in

  7. High population increase rates.

    Science.gov (United States)

    1991-09-01

    In addition to its economic and ethnic difficulties, the USSR faces several pressing demographic problems, including high population increase rates in several of its constituent republics. It has now become clear that although the country's rigid centralized planning succeeded in covering the basic needs of people, it did not lead to welfare growth. Since the 1970s, the Soviet economy has remained sluggish, which as led to increase in the death and birth rates. Furthermore, the ideology that held that demography could be entirely controlled by the country's political and economic system is contradicted by current Soviet reality, which shows that religion and ethnicity also play a significant role in demographic dynamics. Currently, Soviet republics fall under 2 categories--areas with high or low natural population increase rates. Republics with low rates consist of Christian populations (Armenia, Moldavia, Georgia, Byelorussia, Russia, Lithuania, Estonia, Latvia, Ukraine), while republics with high rates are Muslim (Tadzhikistan, Uzbekistan, Turkmenistan, Kirgizia, Azerbaijan Kazakhstan). The later group has natural increase rates as high as 3.3%. Although the USSR as a whole is not considered a developing country, the later group of republics fit the description of the UNFPA's priority list. Another serious demographic issue facing the USSR is its extremely high rate of abortion. This is especially true in the republics of low birth rates, where up to 60% of all pregnancies are terminated by induced abortions. Up to 1/5 of the USSR's annual health care budget is spent on clinical abortions -- money which could be better spent on the production of contraceptives. Along with the recent political and economic changes, the USSR is now eager to deal with its demographic problems.

  8. High voltage pulse generator

    Science.gov (United States)

    Fasching, George E.

    1977-03-08

    An improved high-voltage pulse generator has been provided which is especially useful in ultrasonic testing of rock core samples. An N number of capacitors are charged in parallel to V volts and at the proper instance are coupled in series to produce a high-voltage pulse of N times V volts. Rapid switching of the capacitors from the paralleled charging configuration to the series discharging configuration is accomplished by using silicon-controlled rectifiers which are chain self-triggered following the initial triggering of a first one of the rectifiers connected between the first and second of the plurality of charging capacitors. A timing and triggering circuit is provided to properly synchronize triggering pulses to the first SCR at a time when the charging voltage is not being applied to the parallel-connected charging capacitors. Alternate circuits are provided for controlling the application of the charging voltage from a charging circuit to be applied to the parallel capacitors which provides a selection of at least two different intervals in which the charging voltage is turned "off" to allow the SCR's connecting the capacitors in series to turn "off" before recharging begins. The high-voltage pulse-generating circuit including the N capacitors and corresponding SCR's which connect the capacitors in series when triggered "on" further includes diodes and series-connected inductors between the parallel-connected charging capacitors which allow sufficiently fast charging of the capacitors for a high pulse repetition rate and yet allow considerable control of the decay time of the high-voltage pulses from the pulse-generating circuit.

  9. High Voltage Seismic Generator

    Science.gov (United States)

    Bogacz, Adrian; Pala, Damian; Knafel, Marcin

    2015-04-01

    This contribution describes the preliminary result of annual cooperation of three student research groups from AGH UST in Krakow, Poland. The aim of this cooperation was to develop and construct a high voltage seismic wave generator. Constructed device uses a high-energy electrical discharge to generate seismic wave in ground. This type of device can be applied in several different methods of seismic measurement, but because of its limited power it is mainly dedicated for engineering geophysics. The source operates on a basic physical principles. The energy is stored in capacitor bank, which is charged by two stage low to high voltage converter. Stored energy is then released in very short time through high voltage thyristor in spark gap. The whole appliance is powered from li-ion battery and controlled by ATmega microcontroller. It is possible to construct larger and more powerful device. In this contribution the structure of device with technical specifications is resented. As a part of the investigation the prototype was built and series of experiments conducted. System parameter was measured, on this basis specification of elements for the final device were chosen. First stage of the project was successful. It was possible to efficiently generate seismic waves with constructed device. Then the field test was conducted. Spark gap wasplaced in shallowborehole(0.5 m) filled with salt water. Geophones were placed on the ground in straight line. The comparison of signal registered with hammer source and sparker source was made. The results of the test measurements are presented and discussed. Analysis of the collected data shows that characteristic of generated seismic signal is very promising, thus confirms possibility of practical application of the new high voltage generator. The biggest advantage of presented device after signal characteristics is its size which is 0.5 x 0.25 x 0.2 m and weight approximately 7 kg. This features with small li-ion battery makes

  10. High energy photon response

    International Nuclear Information System (INIS)

    Cummings, F.M.; Yoder, R.C.; Endres, G.W.R.; Kathren, R.L.

    1981-01-01

    This study examines the response of the Hanford 4-chip and 5-chip dosimeter to high energy photons. The dose response of the Hanford Multipurpose Personnel Diometer (HMPD) to photons with energies greater than 0.65 MeV has been evaluated relative to the dose produced by photons from a 60 Co. source. The penetrating dose determined with the HMPD is compared to the 1 cm depth dose in tissue measured with an extrapolation chamber. The results of the study indicate that the HMPD can be used to estimate the 1 cm depth dose in tissue from photons with energies between 0.65 MeV and 3.0 MeV to within an accuracy of 15%. However, the 1 cm depth dose is underestimated by 38% when the dosimeter is irradiated in a beam of very high energy photons produced by bombarding a tungsten target with 25 MeV electrons

  11. Melt Cast High Explosives

    Directory of Open Access Journals (Sweden)

    Stanisław Cudziło

    2014-12-01

    Full Text Available [b]Abstract[/b]. This paper reviews the current state and future developments of melt-cast high explosives. First the compositions, properties and methods of preparation of trinitrotoluene based (TNT conventional mixtures with aluminum, hexogen (RDX or octogen (HMX are described. In the newer, less sensitive explosive formulations, TNT is replaced with dinitroanisole (DNANDNANDNAN and nitrotriazolone (NTONTONTO, nitroguanidine (NG or ammonium perchlorate (AP are the replacement for RDRDX and HMX. Plasticized wax or polymer-based binder systems for melt castable explosives are also included. Hydroxyl terminated polybutadiene (HPTB is the binder of choice, but polyethylene glycol, and polycaprolactone with energetic plasticizers are also used. The most advanced melt-cast explosives are compositions containing energetic thermoplastic elastomers and novel highly energetic compounds (including nitrogen rich molecules in whose particles are nanosized and practically defect-less.[b]Keywords[/b]: melt-cast explosives, detonation parameters

  12. Timetabling at High Schools

    DEFF Research Database (Denmark)

    Sørensen, Matias

    High school institutions face a number of important planning problems during each schoolyear. This Ph.D. thesis considers two of these planning problems: The High School Timetabling Problem (HSTP) and the Consultation Timetabling Problem (CTP). Furthermore a framework for handling various planning...... problems is considered, known as the Generalized Meeting Planning Problem (GMPP). The view taken on these problems is that they are mathematical optimization problems, where the goal is to _nd the optimal solution (from the set of all feasible solutions). This view allows state-of-the-art methods from....... The second part contains the main scienti_c papers composed during the Ph.D. study. The third part of the thesis also contains scienti_c papers, but these are included as an appendix. In the HSTP, the goal is to obtain a timetable for the forthcoming school-year. A timetable consists of lectures scheduled...

  13. High-Performance Networking

    CERN Multimedia

    CERN. Geneva

    2003-01-01

    The series will start with an historical introduction about what people saw as high performance message communication in their time and how that developed to the now to day known "standard computer network communication". It will be followed by a far more technical part that uses the High Performance Computer Network standards of the 90's, with 1 Gbit/sec systems as introduction for an in depth explanation of the three new 10 Gbit/s network and interconnect technology standards that exist already or emerge. If necessary for a good understanding some sidesteps will be included to explain important protocols as well as some necessary details of concerned Wide Area Network (WAN) standards details including some basics of wavelength multiplexing (DWDM). Some remarks will be made concerning the rapid expanding applications of networked storage.

  14. High temperature structural silicides

    International Nuclear Information System (INIS)

    Petrovic, J.J.

    1997-01-01

    Structural silicides have important high temperature applications in oxidizing and aggressive environments. Most prominent are MoSi 2 -based materials, which are borderline ceramic-intermetallic compounds. MoSi 2 single crystals exhibit macroscopic compressive ductility at temperatures below room temperature in some orientations. Polycrystalline MoSi 2 possesses elevated temperature creep behavior which is highly sensitive to grain size. MoSi 2 -Si 3 N 4 composites show an important combination of oxidation resistance, creep resistance, and low temperature fracture toughness. Current potential applications of MoSi 2 -based materials include furnace heating elements, molten metal lances, industrial gas burners, aerospace turbine engine components, diesel engine glow plugs, and materials for glass processing

  15. High temperature probe

    Science.gov (United States)

    Swan, Raymond A.

    1994-01-01

    A high temperature probe for sampling, for example, smokestack fumes, and is able to withstand temperatures of 3000.degree. F. The probe is constructed so as to prevent leakage via the seal by placing the seal inside the water jacket whereby the seal is not exposed to high temperature, which destroys the seal. The sample inlet of the probe is also provided with cooling fins about the area of the seal to provide additional cooling to prevent the seal from being destroyed. Also, a heated jacket is provided for maintaining the temperature of the gas being tested as it passes through the probe. The probe includes pressure sensing means for determining the flow velocity of an efficient being sampled. In addition, thermocouples are located in various places on the probe to monitor the temperature of the gas passing there through.

  16. High energy nuclear physics

    International Nuclear Information System (INIS)

    Meyer, J.

    1988-01-01

    The 1988 progress report of the High Energy Nuclear Physics laboratory (Polytechnic School, France), is presented. The Laboratory research program is focused on the fundamental physics of interactions, on the new techniques for the acceleration of charged particles and on the nuclei double beta decay. The experiments are performed on the following topics: the measurement of the π 0 inclusive production and the photons production in very high energy nuclei-nuclei interactions and the nucleon stability. Concerning the experiments under construction, a new detector for LEP, the study and simulation of the hadronic showers in a calorimeter and the H1 experiment (HERA), are described. The future research programs and the published papers are listed [fr

  17. High thermal load component

    International Nuclear Information System (INIS)

    Fuse, Toshiaki; Tachikawa, Nobuo.

    1996-01-01

    A cooling tube made of a pure copper is connected to the inner portion of an armour (heat resistant member) made of an anisotropic carbon/carbon composite (CFC) material. The CFC material has a high heat conductivity in longitudinal direction of fibers and has low conductivity in perpendicular thereto. Fibers extending in the armour from a heat receiving surface just above the cooling tube are directly connected to the cooling tube. A portion of the fibers extending from a heat receiving surface other than portions not just above the cooling tube is directly bonded to the cooling tube. Remaining fibers are disposed so as to surround the cooling tube. The armour and the cooling tube are soldered using an active metal flux. With such procedures, high thermal load components for use in a thermonuclear reactor are formed, which are excellent in a heat removing characteristic and hardly causes defects such as crackings and peeling. (I.N.)

  18. High temperature measuring device

    Science.gov (United States)

    Tokarz, Richard D.

    1983-01-01

    A temperature measuring device for very high design temperatures (to 2,000.degree. C.). The device comprises a homogenous base structure preferably in the form of a sphere or cylinder. The base structure contains a large number of individual walled cells. The base structure has a decreasing coefficient of elasticity within the temperature range being monitored. A predetermined quantity of inert gas is confined within each cell. The cells are dimensionally stable at the normal working temperature of the device. Increases in gaseous pressure within the cells will permanently deform the cell walls at temperatures within the high temperature range to be measured. Such deformation can be correlated to temperature by calibrating similarly constructed devices under known time and temperature conditions.

  19. High field electron linacs

    International Nuclear Information System (INIS)

    Le Duff, J.

    1985-12-01

    High field electron linacs are considered as potential candidates to provide very high energies beyond LEP. Since almost twenty years not much improvement has been made on linac technologies as they have been mostly kept at low and medium energies to be used as injectors for storage rings. Today, both their efficiency and their performances are being reconsidered, and for instance the pulse compression sheme developed at SLAC and introduced to upgrade the energy of that linac is a first step towards a new generation of linear accelerators. However this is not enough in terms of power consumption and more development is needed to improve both the efficiency of accelerating structures and the performances of RF power sources

  20. Prospects at high energies

    International Nuclear Information System (INIS)

    Quigg, C.

    1988-11-01

    I discuss some possibilities for neutrino experiments in the fixed-target environment of the SPS, Tevatron, and UNK, with their primary proton beams of 0.4, 0.9, and 3.0 TeV. The emphasis is on unfinished business: issues that have been recognized for some time, but not yet resolved. Then I turn to prospects for proton-proton colliders to explore the 1-TeV scale. I review the motivation for new physics in the neighborhood of 1 TeV and mention some discovery possibilities for high-energy, high-luminosity hadron colliders and the implications they would have for neutrino physics. I raise the possibility of the direct study of neutrino interactions in hadron colliders. I close with a report on the status of the SSC project. 38 refs., 17 figs

  1. High altitude organic gold

    DEFF Research Database (Denmark)

    Pouliot, Mariève; Pyakurel, Dipesh; Smith-Hall, Carsten

    2018-01-01

    . Heightened demand in China over the past 15 years, coupled with limited production, has led to a price hike and increased economic importance of harvests to rural households throughout the species’ range. There is, however, limited knowledge on the actors and profit distribution in the O. sinensis production...... by collectors, limited value enhancement, and a high degree of network and territorial embeddedness. Conclusions O. sinensis income is of major economic importance for rural households at the margin of its distribution range in Nepal. Production networks operated by informal actors establishing trust......Ethnopharmacological relevance Ophiocordyceps sinensis (Berk.) G.H.Sung, J.M.Sung, Hywel-Jones & Spatafora, a high altitude Himalayan fungus-caterpillar product found in alpine meadows in China, Bhutan, Nepal, and India, has been used in the Traditional Chinese Medicine system for over 2000 years...

  2. High resolution (transformers.

    Science.gov (United States)

    Garcia-Souto, Jose A; Lamela-Rivera, Horacio

    2006-10-16

    A novel fiber-optic interferometric sensor is presented for vibrations measurements and analysis. In this approach, it is shown applied to the vibrations of electrical structures within power transformers. A main feature of the sensor is that an unambiguous optical phase measurement is performed using the direct detection of the interferometer output, without external modulation, for a more compact and stable implementation. High resolution of the interferometric measurement is obtained with this technique (transformers are also highlighted.

  3. High Solids Coating System

    Science.gov (United States)

    1979-04-01

    SITATEMENT rot tho ahatrai .nti,,ed in IfllorM 0, It diIIIorenl Itroft I.port) 15L %UPPLEMENTARY NOTES 19, KEY WORDS (Continiou on roveaou oido It...yji1 :𔃻ppeŽ r prt rni j Lr ,, [VQ I urt, her eL ve.Luprnent into high solids coating systems. The Acryloid AU-568 hns many of the desirable properties

  4. High Nitrogen Stainless Steel

    Science.gov (United States)

    2011-07-19

    crack growth (FCG) test (ASTM E 647-95a) - square bar specimen of 0.4x0.4x2.8 in. in L-orientation with a Charpy notch at the mid- length for SCC...Hydrogen Embrittlement in Steel by the Increment Loading Technique. Fractography: After the stress-life fatigue tests , the fracture surface morphology...NAWCADPAX/TR-2011/162 HIGH NITROGEN STAINLESS STEEL by E. U. Lee R. Taylor 19 July 2011 Approved for

  5. Highly Concurrent Scalar Processing.

    Science.gov (United States)

    1986-01-01

    rearrangement arise from data dependencies between instructions, hence it is critical that artificial - dependencies are eliminated whenever possible...An important class of artificial depen- *. dencies arise due to register reuse. In the following example, no parallelism can be • . exploited in the...specific procedure call site. The use of inteligent procedure expansion techniques is expected to be crucial to the achievement of high performance

  6. High voltage generator

    Science.gov (United States)

    Schwemin, A. J.

    1959-03-17

    A generator for producing relatively large currents at high voltages is described. In general, the invention comprises a plurality of capacitors connected in series by a plurality of switches alternately disposed with the capacitors. The above-noted circuit is mounted for movement with respect to contact members and switch closure means so that a load device and power supply are connected across successive numbers of capacitors, while the other capacitors are successively charged with the same power supply.

  7. High Speed Compressor Study

    Science.gov (United States)

    2011-12-21

    requirement for a high velocity and low force, and in this case the limit is typically the maximum stroke capability as determined by the springs...In a gas spring, hopefully there will be very little work done (if the losses are small), and the “P-V ” loop will be a thin “ sausage ...thickness). In this case the component, as designed for lower frequency operation, may still have plenty of ‘margin’ at higher frequencies

  8. High Resolution Spectral Analysis

    Science.gov (United States)

    2006-10-25

    liable methods for high resolution spectral analysis of multivariable processes, as well as to distance measures for quantitative assessment of...called "modern nonlinear spectral analysis methods " [27]. An alternative way to reconstruct /„(#), based on Tn, is the periodogram/correlogram f{6...eie). A homotopy method was proposed in [8, 9] leading to a differential equation for A(T) in a homotopy variable r. If the statistics are consistent

  9. Probability in High Dimension

    Science.gov (United States)

    2014-06-30

    set of methods, many of which have their origin in probability in Banach spaces , that arise across a broad range of contemporary problems in di↵erent...salesman problem, . . . • Probability in Banach spaces : probabilistic limit theorems for Banach - valued random variables, empirical processes, local...theory of Banach spaces , geometric functional analysis, convex geometry. • Mixing times and other phenomena in high-dimensional Markov chains. At

  10. Ultra high resolution tomography

    Energy Technology Data Exchange (ETDEWEB)

    Haddad, W.S.

    1994-11-15

    Recent work and results on ultra high resolution three dimensional imaging with soft x-rays will be presented. This work is aimed at determining microscopic three dimensional structure of biological and material specimens. Three dimensional reconstructed images of a microscopic test object will be presented; the reconstruction has a resolution on the order of 1000 A in all three dimensions. Preliminary work with biological samples will also be shown, and the experimental and numerical methods used will be discussed.

  11. Highly Autonomous Systems Workshop

    OpenAIRE

    Doyle, Richard; Rasmussen, Robert; Man, Guy; Patel, Keyur

    1998-01-01

    Researchers and technology developers from the National Aeronautics and Space Administration (NASA), other government agencies, academia, and industry recently met in Pasadena, California, to take stock of past and current work and future challenges in the application of AI to highly autonomous systems. The meeting was catalyzed by new opportunities in developing autonomous spacecraft for NASA and was in part a celebration of the fictional birth year of the HAL-9000 computer.

  12. High energy medical accelerators

    International Nuclear Information System (INIS)

    Mandrillon, P.

    1990-01-01

    The treatment of tumours with charged particles, ranging from protons to 'light ions' (carbon, oxygen, neon), has many advantages, but up to now has been little used because of the absence of facilities. After the successful pioneering work carried out with accelerators built for physics research, machines dedicated to this new radiotherapy are planned or already in construction. These high energy medical accelerators are presented in this paper. (author) 15 refs.; 14 figs.; 8 tabs

  13. Theoretical high energy physics

    International Nuclear Information System (INIS)

    Lee, T.D.

    1990-05-01

    This report discusses progress on theoretical high energy physics at Columbia University in New York City. Some of the topics covered are: Chern-Simons gauge field theories; dynamical fermion QCD calculations; lattice gauge theory; the standard model of weak and electromagnetic interactions; Boson-fermion model of cuprate superconductors; S-channel theory of superconductivity and axial anomaly and its relation to spin in the parton model

  14. High voltage pulse conditioning

    International Nuclear Information System (INIS)

    Springfield, R.M.; Wheat, R.M.

    1990-01-01

    This patent describes an apparatus for conditioning high voltage pulses from particle accelerators in order to shorten the rise times of the pulses. Flashover switches in the cathode stalk of the transmission line hold off conduction for a determinable period of time, reflecting the early portion of the pulses. Diodes upstream of the switches divert energy into the magnetic and electrostatic storage of the capacitance and inductance inherent to the transmission line until the switches close

  15. High Thermal Conductivity Materials

    CERN Document Server

    Shinde, Subhash L

    2006-01-01

    Thermal management has become a ‘hot’ field in recent years due to a need to obtain high performance levels in many devices used in such diverse areas as space science, mainframe and desktop computers, optoelectronics and even Formula One racing cars! Thermal solutions require not just taking care of very high thermal flux, but also ‘hot spots’, where the flux densities can exceed 200 W/cm2. High thermal conductivity materials play an important role in addressing thermal management issues. This volume provides readers a basic understanding of the thermal conduction mechanisms in these materials and discusses how the thermal conductivity may be related to their crystal structures as well as microstructures developed as a result of their processing history. The techniques for accurate measurement of these properties on large as well as small scales have been reviewed. Detailed information on the thermal conductivity of diverse materials including aluminum nitride (AlN), silicon carbide (SiC), diamond, a...

  16. High altitude dermatology

    Directory of Open Access Journals (Sweden)

    G K Singh

    2017-01-01

    Full Text Available Approximately, 140 million people worldwide live permanently at high altitudes (HAs and approximately another 40 million people travel to HA area (HAA every year for reasons of occupation, sports or recreation. In India, whole of Ladakh region, part of Northwest Kashmir, Northern part of Sikkim and Tenga valley of Arunachal are considered inhabited areas of HAA. The low quantity of oxygen, high exposure of ultraviolet (UV light, very low humidity, extreme subzero temperature in winter, high wind velocity, make this region difficult for lowlanders as well as for tourists. Acute mountain sickness, HA pulmonary edema, HA cerebral edema, and thromboembolic conditions are known to occur in HA. However, enough knowledge has not been shared on dermatoses peculiar to this region. Xerosis, UV-related skin disorders (tanning, photomelanosis, acute and chronic sunburn, polymorphic light eruption, chronic actinic dermatitis, actinic cheilitis, etc., cold injuries (frostbite, chilblains, acrocyanosis, erythrocyanosis, etc. nail changes (koilonychias, airborne contact dermatitis, insect bite reaction, and skin carcinoma (basal cell carcinomas, squamous cell carcinomas, and also rarely malignant melanoma are the dermatoses seen in HAAs. Early diagnosis and knowledge of HA dermatoses may prevent serious consequences of disease and improve the quality of life for the visitors as well as for native of the place.

  17. Very high energy colliders

    International Nuclear Information System (INIS)

    Richter, B.

    1985-05-01

    The conclusions are relatively simple, but represent a considerable challenge to the machine builder. High luminosity is essential. We may in the future discover some new kind of high cross section physics, but all we know now indicates that the luminosity has to increase as the square of the center of mass energy. A reasonable luminosity to scale from for electron machines would be 10 33 cm -2 s -1 at a center of mass energy of 3 TeV. The required emittances in very high energy machines are small. It will be a real challenge to produce these small emittances and to maintain them during acceleration. The small emittances probably make acceleration by laser techniques easier, if such techniques will be practical at all. The beam spot sizes are very small indeed. It will be a challenge to design beam transport systems with the necessary freedom from aberration required for these small spot sizes. It would of course help if the beta functions at the collision points could be reduced. Beam power will be large - to paraphrase the old saying, ''power is money'' - and efficient acceleration systems will be required

  18. High performance data transfer

    Science.gov (United States)

    Cottrell, R.; Fang, C.; Hanushevsky, A.; Kreuger, W.; Yang, W.

    2017-10-01

    The exponentially increasing need for high speed data transfer is driven by big data, and cloud computing together with the needs of data intensive science, High Performance Computing (HPC), defense, the oil and gas industry etc. We report on the Zettar ZX software. This has been developed since 2013 to meet these growing needs by providing high performance data transfer and encryption in a scalable, balanced, easy to deploy and use way while minimizing power and space utilization. In collaboration with several commercial vendors, Proofs of Concept (PoC) consisting of clusters have been put together using off-the- shelf components to test the ZX scalability and ability to balance services using multiple cores, and links. The PoCs are based on SSD flash storage that is managed by a parallel file system. Each cluster occupies 4 rack units. Using the PoCs, between clusters we have achieved almost 200Gbps memory to memory over two 100Gbps links, and 70Gbps parallel file to parallel file with encryption over a 5000 mile 100Gbps link.

  19. High energy physics

    International Nuclear Information System (INIS)

    Kernan, A.; Shen, B.C.; Ma, E.

    1997-01-01

    This proposal is for the continuation of the High Energy Physics program at the University of California at Riverside. In hadron collider physics the authors will complete their transition from experiment UA1 at CERN to the DZERO experiment at Fermilab. On experiment UA1 their effort will concentrate on data analysis at Riverside. At Fermilab they will coordinate the high voltage system for all detector elements. They will also carry out hardware/software development for the D0 muon detector. The TPC/Two-Gamma experiment has completed its present phase of data-taking after accumulating 160 pb - 1 of luminosity. The UC Riverside group will continue data and physics analysis and make minor hardware improvement for the high luminosity run. The UC Riverside group is participating in design and implementation of the data acquisition system for the OPAL experiment at LEP. Mechanical and electronics construction of the OPAL hadron calorimeter strip readout system is proceeding on schedule. Data analysis and Monte Carlo detector simulation efforts are proceeding in preparation for the first physics run when IEP operation comenses in fall 1989

  20. High energy physics

    Energy Technology Data Exchange (ETDEWEB)

    Kernan, A.; Shen, B.C.; Ma, E.

    1997-07-01

    This proposal is for the continuation of the High Energy Physics program at the University of California at Riverside. In hadron collider physics the authors will complete their transition from experiment UA1 at CERN to the DZERO experiment at Fermilab. On experiment UA1 their effort will concentrate on data analysis at Riverside. At Fermilab they will coordinate the high voltage system for all detector elements. They will also carry out hardware/software development for the D0 muon detector. The TPC/Two-Gamma experiment has completed its present phase of data-taking after accumulating 160 pb{sup {minus}}1 of luminosity. The UC Riverside group will continue data and physics analysis and make minor hardware improvement for the high luminosity run. The UC Riverside group is participating in design and implementation of the data acquisition system for the OPAL experiment at LEP. Mechanical and electronics construction of the OPAL hadron calorimeter strip readout system is proceeding on schedule. Data analysis and Monte Carlo detector simulation efforts are proceeding in preparation for the first physics run when IEP operation comenses in fall 1989.

  1. HIGH EFFICIENCY SYNGAS GENERATION

    Energy Technology Data Exchange (ETDEWEB)

    Robert J. Copeland; Yevgenia Gershanovich; Brian Windecker

    2005-02-01

    This project investigated an efficient and low cost method of auto-thermally reforming natural gas to hydrogen and carbon monoxide. Reforming is the highest cost step in producing products such as methanol and Fisher Tropsch liquids (i.e., gas to liquids); and reducing the cost of reforming is the key to reducing the cost of these products. Steam reforming is expensive because of the high cost of the high nickel alloy reforming tubes (i.e., indirectly fired reforming tubes). Conventional auto-thermal or Partial Oxidation (POX) reforming minimizes the size and cost of the reformers and provides a near optimum mixture of CO and hydrogen. However POX requires pure oxygen, which consumes power and significantly increases the cost to reforming. Our high efficiency process extracts oxygen from low-pressure air with novel oxygen sorbent and transfers the oxygen to a nickel-catalyzed reformer. The syngas is generated at process pressure (typically 20 to 40 bar) without nitrogen dilution and has a 1CO to 2H{sub 2} ratio that is near optimum for the subsequent production of Fisher-Tropsch liquid to liquids and other chemicals (i.e., Gas to Liquids, GTL). Our high process efficiency comes from the way we transfer the oxygen into the reformer. All of the components of the process, except for the oxygen sorbent, are commonly used in commercial practice. A process based on a longlived, regenerable, oxygen transfer sorbent could substantially reduce the cost of natural gas reforming to syngas. Lower cost syngas (CO + 2H{sub 2}) that is the feedstock for GTL would reduce the cost of GTL and for other commercial applications (e.g., methanol, other organic chemicals). The vast gas resources of Alaska's North Slope (ANS) offer more than 22 Tcf of gas and GTL production in this application alone, and could account for as much as 300,000 to 700,000 bpd for 20 to 30+ years. We developed a new sorbent, which is an essential part of the High Efficiency Oxygen Process (HOP). We tested

  2. Superconductivity under high pressure

    Energy Technology Data Exchange (ETDEWEB)

    Amaya, K.; Shimizu, K.; Takeda, K.; Tateiwa, N.; Muramatsu, T.; Ishizuka, M.; Kobayashi, T.C

    2003-05-01

    In part 1, we review techniques developed in our laboratory for producing the complex extreme condition of very low temperature and ultra-high pressure and those for measuring electrical resistance and magnetization of the sample confined in the extremely small space of the used pressure cell. In part 2, we review our experimental results in search for pressure-induced superconductivity, which have been obtained by the use of developed techniques. Typical examples are shown in the case of simple inorganic and organic molecular crystals, ionic crystals, and magnetic metals.

  3. High pressure induced superconductivity

    Energy Technology Data Exchange (ETDEWEB)

    Amaya, K.; Shimizu, K

    2003-10-15

    We have developed complex extreme condition of very low temperature down to 30 mK and ultra high pressure exceeding 200 GPa by assembling compact diamond anvil cell (DAC) on a powerful {sup 3}He/{sup 4}He dilution refrigerator. We have also developed measuring techniques of electrical resistance, magnetization and optical measurement for the sample confined in the sample space of the DAC. Using the newly developed apparatus and techniques, we have searched for superconductivity in various materials under pressure. In this paper, we will shortly review our newly developed experimental apparatus and techniques and discuss a few examples of pressure induced superconductivity which were observed recently.

  4. High energy neutrinos

    OpenAIRE

    Masip, M.

    2018-01-01

    We describe several components in the diffuse flux of high energy neutrinos reaching the Earth and discuss whether they could explain IceCube's observations. Then we focus on TeV neutrinos from the Sun. We show that this solar neutrino flux is correlated with the cosmic-ray shadow of the Sun measured by HAWC, and we find that it is much larger than the flux of atmospheric neutrinos. Stars like our Sun provide neutrinos with a very steep spectrum and no associated gammas. We argue that this is...

  5. Knees Lifted High

    Centers for Disease Control (CDC) Podcasts

    2008-08-04

    The Eagle Books are a series of four books that are brought to life by wise animal characters - Mr. Eagle, Miss Rabbit, and Coyote - who engage Rain That Dances and his young friends in the joy of physical activity, eating healthy foods, and learning from their elders about health and diabetes prevention. Knees Lifted High gives children fun ideas for active outdoor play.  Created: 8/4/2008 by National Center for Chronic Disease Prevention and Health Promotion (NCCDPHP).   Date Released: 8/5/2008.

  6. High Energy Halogen Chemistry.

    Science.gov (United States)

    1976-01-01

    WPIilPiPPW*PKiS>WW!!lipi»ra«35WTT’^ ! m ESPORT NO. OKR 1-5 (Annual) PERIOD COVERED: 1 DBCEM^SR 1971* THROUGH 1 DECEMBER 1975 f £ HIGH ENERGY...the 3-chloro- 2-butyl perchlorate thus prepared from cis-2-butene oxide was identical with that obtained from cis-2-butene and dichlorine heptoxide...and that from trans- 2-butene oxide was identical with the trans-2-butene product. Thus, the forma- tion of 3-chloro-2-butyl perchlorate from 2

  7. High Power Vanadate lasers

    CSIR Research Space (South Africa)

    Strauss, HJ

    2006-07-01

    Full Text Available ) Poor thermal contact between crystal and mount barb2right stronger thermal lenses and thermal stress barb2right bad beams and / or crystal damage. 2) Nd:GdVO4 spectrally very close to Nd:YVO4. Much uncertainty about the thermal properties barb2... properties during lasing can be made at two important wavelengths. 3) Pi-polarisation barb2rightWeakest thermal lens barb2right Ideal for high output power levels Future Work • Determine the thermal lens focal lengths over a wider range of pump powers...

  8. High energy physics

    International Nuclear Information System (INIS)

    Fortney, L.R.; Goshaw, A.T.; Walker, W.D.

    1991-01-01

    This progress report presents a review of research done over the past five years by the Duke High Energy Physics Group. This research has been centered at Fermilab where we have had a continuing involvement with both the Tevatron collider and fixed-target programs. In 1988 we began extensive detector R ampersand D for the SSC through its Major Subsystem Program. Duke has been an active member of the Solenoidal Detector Collaboration (SDC) since its formation. These last five years has also been used to finish the analysis of data from a series of hybrid bubble chamber experiments which formed the core of Duke's research program in the early 1980's

  9. High energy cosmic rays

    CERN Document Server

    Stanev, Todor

    2010-01-01

    Offers an accessible text and reference (a cosmic-ray manual) for graduate students entering the field and high-energy astrophysicists will find this an accessible cosmic-ray manual Easy to read for the general astronomer, the first part describes the standard model of cosmic rays based on our understanding of modern particle physics. Presents the acceleration scenario in some detail in supernovae explosions as well as in the passage of cosmic rays through the Galaxy. Compares experimental data in the atmosphere as well as underground are compared with theoretical models

  10. Shielding high energy accelerators

    CERN Document Server

    Stevenson, Graham Roger

    2001-01-01

    After introducing the subject of shielding high energy accelerators, point source, line-of-sight models, and in particular the Moyer model. are discussed. Their use in the shielding of proton and electron accelerators is demonstrated and their limitations noted. especially in relation to shielding in the forward direction provided by large, flat walls. The limitations of reducing problems to those using it cylindrical geometry description are stressed. Finally the use of different estimators for predicting dose is discussed. It is suggested that dose calculated from track-length estimators will generally give the most satisfactory estimate. (9 refs).

  11. High temperature reaction kinetics

    International Nuclear Information System (INIS)

    Jonah, C.D.; Beno, M.F.; Mulac, W.A.; Bartels, D.

    1985-01-01

    During the last year the dependence of the apparent rate of OD + CO on water pressure was measured at 305, 570, 865 and 1223 K. An explanation was found and tested for the H 2 O dependence of the apparent rate of OH(OD) + CO at high temperatures. The isotope effect for OH(D) with CO was determined over the temperature range 330 K to 1225 K. The reason for the water dependence of the rate of OH(OD) + CO near room temperatures has been investigated but no clear explanation has been found. 1 figure

  12. Theoretical High Energy Physics

    Energy Technology Data Exchange (ETDEWEB)

    Christ, Norman H.; Weinberg, Erick J.

    2014-07-14

    we provide reports from each of the six faculty supported by the Department of Energy High Energy Physics Theory grant at Columbia University. Each is followed by a bibliography of the references cited. A complete list of all of the publications in the 12/1/2010-04/30/2014 period resulting from research supported by this grant is provided in the following section. The final section lists the Ph.D. dissertations based on research supported by the grant that were submitted during this period.

  13. High-multiplicity processes

    International Nuclear Information System (INIS)

    Shelkov, G.; Sisakyan, A.; Mandzhavidze, I.

    1999-01-01

    We wish to demonstrate that investigation of asymptotically high multiplicity (AHM) hadron reactions may solve, or at least clear up, a number of problems unsolvable by other ways. We would lean upon the idea: (i) the reactions final state entropy is proportional to multiplicity and, by this reason, just in the AHM domain one may expect the equilibrium final state and (ii) the AHM final state is cold because of the energy-momentum conservation laws. This means that the collective phenomena may become important in the AHM domain. The possibility of hard processes dominance is considered also

  14. Highly excited atoms

    International Nuclear Information System (INIS)

    Kleppner, D.; Littman, M.G.; Zimmerman, M.L.

    1981-01-01

    Highly excited atoms are often called Rydberg atoms. These atoms have a wealth of exotic properties which are discussed. Of special interest, are the effects of electric and magnetic fields on Rydberg atoms. Ordinary atoms are scarcely affected by an applied electric or magnetic field; Rydberg atoms can be strongly distorted and even pulled apart by a relatively weak electric field, and they can be squeezed into unexpected shapes by a magnetic field. Studies of the structure of Rydberg atoms in electric and magnetic fields have revealed dramatic atomic phenomena that had not been observed before

  15. High-power electronics

    CERN Document Server

    Kapitsa, Petr Leonidovich

    1966-01-01

    High-Power Electronics, Volume 2 presents the electronic processes in devices of the magnetron type and electromagnetic oscillations in different systems. This book explores the problems of electronic energetics.Organized into 11 chapters, this volume begins with an overview of the motion of electrons in a flat model of the magnetron, taking into account the in-phase wave and the reverse wave. This text then examines the processes of transmission of electromagnetic waves of various polarization and the wave reflection from grids made of periodically distributed infinite metal conductors. Other

  16. ALICE High Level Trigger

    CERN Multimedia

    Alt, T

    2013-01-01

    The ALICE High Level Trigger (HLT) is a computing farm designed and build for the real-time, online processing of the raw data produced by the ALICE detectors. Events are fully reconstructed from the raw data, analyzed and compressed. The analysis summary together with the compressed data and a trigger decision is sent to the DAQ. In addition the reconstruction of the events allows for on-line monitoring of physical observables and this information is provided to the Data Quality Monitor (DQM). The HLT can process event rates of up to 2 kHz for proton-proton and 200 Hz for Pb-Pb central collisions.

  17. Clojure high performance programming

    CERN Document Server

    Kumar, Shantanu

    2013-01-01

    This is a short, practical guide that will teach you everything you need to know to start writing high performance Clojure code.This book is ideal for intermediate Clojure developers who are looking to get a good grip on how to achieve optimum performance. You should already have some experience with Clojure and it would help if you already know a little bit of Java. Knowledge of performance analysis and engineering is not required. For hands-on practice, you should have access to Clojure REPL with Leiningen.

  18. High resolution backscattering instruments

    International Nuclear Information System (INIS)

    Coldea, R.

    2001-01-01

    The principle of operation of indirect-geometry time-of-flight spectrometers are presented, including the IRIS at the ISIS spallation neutron source. The key features that make those types of spectrometers ideally suited for low-energy spectroscopy are: high energy resolution over a wide dynamic range, and simultaneous measurement over a large momentum transfer range provided by the wide angular detector coverage. To exemplify these features are discussed of single-crystal experiments of the spin dynamics in the two-dimensional frustrated quantum magnet Cs 2 CuCl 4 . (R.P.)

  19. High temperature superconductors

    CERN Document Server

    Paranthaman, Parans

    2010-01-01

    This essential reference provides the most comprehensive presentation of the state of the art in the field of high temperature superconductors. This growing field of research and applications is currently being supported by numerous governmental and industrial initiatives in the United States, Asia and Europe to overcome grid energy distribution issues. The technology is particularly intended for densely populated areas. It is now being commercialized for power-delivery devices, such as power transmission lines and cables, motors and generators. Applications in electric utilities include current limiters, long transmission lines and energy-storage devices that will help industries avoid dips in electric power.

  20. High dimensional entanglement

    CSIR Research Space (South Africa)

    Mc

    2012-07-01

    Full Text Available stream_source_info McLaren_2012.pdf.txt stream_content_type text/plain stream_size 2190 Content-Encoding ISO-8859-1 stream_name McLaren_2012.pdf.txt Content-Type text/plain; charset=ISO-8859-1 High dimensional... entanglement M. McLAREN1,2, F.S. ROUX1 & A. FORBES1,2,3 1. CSIR National Laser Centre, PO Box 395, Pretoria 0001 2. School of Physics, University of the Stellenbosch, Private Bag X1, 7602, Matieland 3. School of Physics, University of Kwazulu...

  1. High gradient superconducting quadrupoles

    International Nuclear Information System (INIS)

    Lundy, R.A.; Brown, B.C.; Carson, J.A.; Fisk, H.E.; Hanft, R.H.; Mantsch, P.M.; McInturff, A.D.; Remsbottom, R.H.

    1987-07-01

    Prototype superconducting quadrupoles with a 5 cm aperture and gradient of 16 kG/cm have been built and tested as candidate magnets for the final focus at SLC. The magnets are made from NbTi Tevatron style cable with 10 inner and 14 outer turns per quadrant. Quench performance and multipole data are presented. Design and data for a low current, high gradient quadrupole, similar in cross section but wound with a cable consisting of five insulated conductors are also discussed

  2. High performance AC drives

    CERN Document Server

    Ahmad, Mukhtar

    2010-01-01

    This book presents a comprehensive view of high performance ac drives. It may be considered as both a text book for graduate students and as an up-to-date monograph. It may also be used by R & D professionals involved in the improvement of performance of drives in the industries. The book will also be beneficial to the researchers pursuing work on multiphase drives as well as sensorless and direct torque control of electric drives since up-to date references in these topics are provided. It will also provide few examples of modeling, analysis and control of electric drives using MATLAB/SIMULIN

  3. High Test Peroxide High Sealing Conical Seal, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — High Test Peroxide (HTP) Highly Compatible High Sealing Conical Seals are necessary for ground test operations and space based applications. Current conical seals...

  4. DURIP95/Ultra High Precision Diagnostic High Temperature Laboratory

    National Research Council Canada - National Science Library

    Newaz, Golam M

    1997-01-01

    The DURIP grant was used to develop an efficient high temperature laboratory with high precision instruments to make deformation and load measurements in high temperature materials including advanced composites...

  5. High Performance Window Retrofit

    Energy Technology Data Exchange (ETDEWEB)

    Shrestha, Som S. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Hun, Diana E. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Desjarlais, Andre Omer [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States)

    2013-12-01

    The US Department of Energy (DOE) Office of Energy Efficiency and Renewable Energy (EERE) and Traco partnered to develop high-performance windows for commercial building that are cost-effective. The main performance requirement for these windows was that they needed to have an R-value of at least 5 ft2∙ F∙h/Btu. This project seeks to quantify the potential energy savings from installing these windows in commercial buildings that are at least 20 years old. To this end, we are conducting evaluations at a two-story test facility that is representative of a commercial building from the 1980s, and are gathering measurements on the performance of its windows before and after double-pane, clear-glazed units are upgraded with R5 windows. Additionally, we will use these data to calibrate EnergyPlus models that we will allow us to extrapolate results to other climates. Findings from this project will provide empirical data on the benefits from high-performance windows, which will help promote their adoption in new and existing commercial buildings. This report describes the experimental setup, and includes some of the field and simulation results.

  6. High energy magnetic spectroscopy

    International Nuclear Information System (INIS)

    Loewenhaupt, M.

    1984-01-01

    The purpose of this paper is twofold: (i) to elucidate the possibilities and limitations of neutron scattering experiments with high energy transfers at low momentum transfers from the view point of the kinematical conditions of the scattering process and (ii) to discuss some examples of high energy magnetic excitations in the field of 4f- and 5f- magnetism. The outcome of point (i) will determine the range of possible energy transfer i.e. will give a reasonable upper bound of 0.5 to leV of energy transfer for momentum transfers around 2 to 5 A -1 . This extends the available omega-range by roughly a factor of 10 compared to the conventional magnetic scattering at reactors. Any further, significant increase in energy transfer, however, is not very likely even with very powerful future spallation sources. Thus it is sufficient to restrict the discussion of possible magnetic experiments to energy transfer up to 0.5 or 1 eV

  7. Giant high occipital encephalocele

    Directory of Open Access Journals (Sweden)

    Agrawal Amit

    2016-03-01

    Full Text Available Encephaloceles are rare embryological mesenchymal developmental anomalies resulting from inappropriate ossification in skull through with herniation of intracranial contents of the sac. Encephaloceles are classified based on location of the osseous defect and contents of sac. Convexity encephalocele with osseous defect in occipital bone is called occipital encephalocele. Giant occipital encephaloceles can be sometimes larger than the size of baby skull itself and they pose a great surgical challenge. Occipital encephaloceles (OE are further classified as high OE when defect is only in occipital bone above the foramen magnum, low OE when involving occipital bone and foramen magnum and occipito-cervical when there involvement of occipital bone, foramen magnum and posterior upper neural arches. Chiari III malformation can be associated with high or low occipital encephaloceles. Pre-operatively, it is essential to know the size of the sac, contents of the sac, relation to the adjacent structures, presence or absence of venous sinuses/vascular structures and osseous defect size. Sometimes it becomes imperative to perform both CT and MRI for the necessary information. Volume rendered CT images can depict the relation of osseous defect to foramen magnum and provide information about upper neural arches which is necessary in classifying these lesions.

  8. High energy ion microprobes

    International Nuclear Information System (INIS)

    Nobiling, R.

    1983-01-01

    Analysis with high energy ion beams can be applied to microscopic samples or substructures of complex specimens by using nuclear or proton microprobes. Focusing of high energy ion beams requires specially designed collimators and lens systems. At present, beam diameters of 1 μm are obtained. The lateral resolution of the instruments, however, is not limited to this 1 μm. Consequently microprobe analysis with ion beams in favourable cases can provide better analytical possibilities and lateral resolution as compared with electron microprobes. Due to aberrations an improvement of beam diameters to less than 0.5-1 μm requires compensation of at least the chromatic aberration. The most important fields of application are mineralogy, materials science and biology. With nuclear reactions and PIXE (particle induced X-ray emission) the whole periodic table can be measured with detection limits down to the ppm level (weight fraction). The virtual lack of beam broadening by scattering in samples of a few μm thickness makes a kind of microscopic chemical tomography possible. (orig.)

  9. High temperature thermometric phosphors

    Science.gov (United States)

    Allison, Stephen W.; Cates, Michael R.; Boatner, Lynn A.; Gillies, George T.

    1999-03-23

    A high temperature phosphor consists essentially of a material having the general formula LuPO.sub.4 :Dy.sub.(x),Eu.sub.y) wherein: 0.1 wt %.ltoreq.x.ltoreq.20 wt % and 0.1 wt %.ltoreq.y.ltoreq.20 wt %. The high temperature phosphor is in contact with an article whose temperature is to be determined. The article having the phosphor in contact with it is placed in the environment for which the temperature of the article is to be determined. The phosphor is excited by a laser causing the phosphor to fluoresce. The emission from the phosphor is optically focused into a beam-splitting mirror which separates the emission into two separate emissions, the emission caused by the dysprosium dopant and the emission caused by the europium dopent. The separated emissions are optically filtered and the intensities of the emission are detected and measured. The ratio of the intensity of each emission is determined and the temperature of the article is calculated from the ratio of the intensities of the separate emissions.

  10. Thoracic Idiopathic Scoliosis Severity Is Highly Correlated with 3D Measures of Thoracic Kyphosis.

    Science.gov (United States)

    Sullivan, T Barrett; Reighard, Fredrick G; Osborn, Emily J; Parvaresh, Kevin C; Newton, Peter O

    2017-06-07

    Loss of thoracic kyphosis has been associated with thoracic idiopathic scoliosis. Modern 3-dimensional (3D) imaging systems allow more accurate characterization of the scoliotic deformity than traditional radiographs. In this study, we utilized 3D calculations to characterize the association between increasing scoliosis severity and changes in the sagittal and axial planes. Patients evaluated in a scoliosis clinic and determined to have either a normal spine or idiopathic scoliosis were included in the analysis. All underwent upright, biplanar radiography with 3D reconstructions. Two-dimensional (2D) measurements of the magnitude of the thoracic major curve and the thoracic kyphosis were recorded. Image processing and MATLAB analysis were utilized to produce a 3D calculation of thoracic kyphosis and apical vertebral axial rotation. Regression analysis was performed to determine the correlation of 2D kyphosis, 3D kyphosis, and apical axial rotation with the magnitude of the thoracic major curve. The 442 patients for whom 2D and 3D data were collected had a main thoracic curve magnitude ranging from 1° to 118°. Linear regression analysis of the 2D and 3D T5-T12 kyphosis versus main thoracic curve magnitude yielded significant models (p scoliosis magnitude increased, at a rate of more than half the increase in the main thoracic curve magnitude. Analysis confirmed a surprisingly strong correlation between scoliosis severity and loss of 3D kyphosis that was absent in the 2D analysis. A similarly strong correlation between curve magnitude and apical axial rotation was evident. These findings lend further credence to the concept that scoliosis progresses in the coronal, sagittal, and axial planes simultaneously. The findings of this study suggest that 3D assessment is critical for adequate characterization of the multiplanar deformity of idiopathic scoliosis and deformity in the sagittal plane is linked to deformity in the coronal plane. Increasing severity of coronal

  11. MANAGING HIGH-END, HIGH-VOLUME INNOVATIVE PRODUCTS

    Directory of Open Access Journals (Sweden)

    Gembong Baskoro

    2008-01-01

    Full Text Available This paper discuses the concept of managing high-end, high-volume innovative products. High-end, high-volume consumer products are products that have considerable influence to the way of life. Characteristic of High-end, high-volume consumer products are (1 short cycle time, (2 quick obsolete time, and (3 rapid price erosion. Beside the disadvantages that they are high risk for manufacturers, if manufacturers are able to understand precisely the consumer needs then they have the potential benefit or success to be the market leader. High innovation implies to high utilization of the user, therefore these products can influence indirectly to the way of people life. The objective of managing them is to achieve sustainability of the products development and innovation. This paper observes the behavior of these products in companies operated in high-end, high-volume consumer product.

  12. High energy astrophysical techniques

    CERN Document Server

    Poggiani, Rosa

    2017-01-01

    This textbook presents ultraviolet and X-ray astronomy, gamma-ray astronomy, cosmic ray astronomy, neutrino astronomy, and gravitational wave astronomy as distinct research areas, focusing on the astrophysics targets and the requirements with respect to instrumentation and observation methods. The purpose of the book is to bridge the gap between the reference books and the specialized literature. For each type of astronomy, the discussion proceeds from the orders of magnitude for observable quantities. The physical principles of photon and particle detectors are then addressed, and the specific telescopes and combinations of detectors, presented. Finally the instruments and their limits are discussed with a view to assisting readers in the planning and execution of observations. Astronomical observations with high-energy photons and particles represent the newest additions to multimessenger astronomy and this book will be of value to all with an interest in the field.

  13. High energy physics

    Energy Technology Data Exchange (ETDEWEB)

    Kernan, A.; Shen, B.C.; Ma, E.

    1997-07-01

    Hadron collider studies will focus on: (i) the search for the top quark with the newly installed D0 detector at the Fermilab Tevatron collider, (ii) the upgrade of the D0 detector to match the new main injector luminosity and (iii) R&D on silicon microstrip tracking devices for the SSC. High statistics studies of Z{sup 0} decay will continue with the OPAL detector at LEP. These studies will include a direct measurement of Z decay to neutrinos, the search for Higgs and heavy quark decays of Z. Preparations for the Large Scintillation Neutrino Detector (LSND) to measure neutrino oscillations at LAMPF will focus on data acquisition and testing of photomultiplier tubes. In the theoretical area E. Ma will concentrate on mass-generating radiative mechanisms for light quarks and leptons in renormalizable gauge field theories. J. Wudka`s program includes a detailed investigation of the magnetic-flip approach to the solar neutrino.

  14. High brightness electron sources

    Energy Technology Data Exchange (ETDEWEB)

    Sheffield, R.L.

    1995-07-01

    High energy physics accelerators and free electron lasers put increased demands on the electron beam sources. This paper describes the present research on attaining intense bright electron beams using photoinjectors. Recent results from the experimental programs will be given. The performance advantages and difficulties presently faced by researchers will be discussed, and the following topics will be covered. Progress has been made in photocathode materials, both in lifetime and quantum efficiency. Cesium telluride has demonstrated significantly longer lifetimes than cesium antimonide at 10{sup {minus}8} torr. However, the laser system is more difficult because cesium telluride requires quadrupled YLF instead of the doubled YLF required for cesium antimonide. The difficulty in using photoinjectors is primarily the drive laser, in particular the amplitude stability. Finally, emittance measurements of photoinjector systems can be complicated by the non-thermal nature of the electron beam. An example of the difficulty in measuring beam emittance is given.

  15. High Antibiotic Consumption

    DEFF Research Database (Denmark)

    Malo, Sara; José Rabanaque, María; Feja, Cristina

    2014-01-01

    as their exposure to antibiotics. Data on outpatient prescribing of antimicrobials (ATC J01) in 2010 were obtained from a prescription database covering Aragón (northeastern Spain). The antimicrobial consumption at the individual level was analysed both according to the volume of DDD and the number of packages...... purchased per year. Heavy antibiotic users were identified according to Lorenz curves and characterized by age, gender, and their antimicrobial prescription profile. Lorenz curves demonstrated substantial differences in the individual use of antimicrobials. Heavy antibiotic users (5% of individuals...... with highest consumption) were responsible for 21% of the total DDD consumed and received ≥6 packages per year. Elderly adults (≥60 years) and small children (0-9 years) were those exposed to the highest volume of antibiotics and with the most frequent exposure, respectively. Heavy users received a high...

  16. High Time Resolution Astrophysics

    CERN Document Server

    Phelan, Don; Shearer, Andrew

    2008-01-01

    High Time Resolution Astrophysics (HTRA) is an important new window to the universe and a vital tool in understanding a range of phenomena from diverse objects and radiative processes. This importance is demonstrated in this volume with the description of a number of topics in astrophysics, including quantum optics, cataclysmic variables, pulsars, X-ray binaries and stellar pulsations to name a few. Underlining this science foundation, technological developments in both instrumentation and detectors are described. These instruments and detectors combined cover a wide range of timescales and can measure fluxes, spectra and polarisation. These advances make it possible for HTRA to make a big contribution to our understanding of the Universe in the next decade.

  17. High Voltage Charge Pump

    KAUST Repository

    Emira, Ahmed A.

    2014-10-09

    Various embodiments of a high voltage charge pump are described. One embodiment is a charge pump circuit that comprises a plurality of switching stages each including a clock input, a clock input inverse, a clock output, and a clock output inverse. The circuit further comprises a plurality of pumping capacitors, wherein one or more pumping capacitors are coupled to a corresponding switching stage. The circuit also comprises a maximum selection circuit coupled to a last switching stage among the plurality of switching stages, the maximum selection circuit configured to filter noise on the output clock and the output clock inverse of the last switching stage, the maximum selection circuit further configured to generate a DC output voltage based on the output clock and the output clock inverse of the last switching stage.

  18. ULTRA HIGH VACUUM VALVE

    Science.gov (United States)

    Fry, W.A.

    1962-05-29

    A valve for high vacuum applications such as the CStellarator where chamber pressures as low as 2 x 10/sup -10/ mm Hg are necessary is designed with a line-of-sight path through the valve for visual inspection of the contents of reactants in such chambers. The valve comprises a turnable resilient metal ball having an aperture therethrough, means for selectively turning the ball to rotate the axis of its line-of-sight path, and soft, deformable opposing orifices that are movable relatively toward said ball to seal with opposite ball surfaces upon said movement of said axis of said line-of-sight path. The valve also includes a bellows seal connected between said orifices and internal actuating means that eliminates the requirement for gasketed turnable valve closing stems. (AEC)

  19. Highly resolving computerized tomography

    International Nuclear Information System (INIS)

    Kurtz, B.; Petersen, D.; Walter, E.

    1984-01-01

    With the development of highly-resolving devices for computerized tomography, CT diagnosis of the lumbar vertebral column has gained increasing importance. As an ambulatory, non-invasive method it has proved in comparative studies to be at least equivalent to myelography in the detection of dislocations of inter-vertebral disks (4,6,7,15). Because with modern devices not alone the bones, but especially the spinal soft part structures are clearly and precisely presented with a resolution of distinctly below 1 mm, a further improvement of the results is expected as experience will increase. The authors report on the diagnosis of the lumbar vertebral column with the aid of a modern device for computerized tomography and wish to draw particular attention to the possibility of doing this investigation as a routine, and to the diagnostic value of secondary reconstructions. (BWU) [de

  20. Superstructure high efficiency photovoltaics

    Science.gov (United States)

    Wagner, M.; So, L. C.; Leburton, J. P.

    1987-01-01

    A novel class of photovoltaic cascade structures is introduced which features multijunction upper subcells. These superstructure high efficiency photovoltaics (SHEP's) exhibit enhanced upper subcell spectral response because of the additional junctions which serve to reduce bulk recombination losses by decreasing the mean collection distance for photogenerated minority carriers. Two possible electrical configurations were studied and compared: a three-terminal scheme that allows both subcells to be operated at their individual maximum power points and a two-terminal configuration with an intercell ohmic contact for series interconnection. The three-terminal devices were found to be superior both in terms of beginning-of-life expectancy and radiation tolerance. Realistic simulations of three-terminal AlGaAs/GaAs SHEP's show that one sun AMO efficiencies in excess of 26 percent are possible.

  1. High level nuclear wastes

    International Nuclear Information System (INIS)

    Lopez Perez, B.

    1987-01-01

    The transformations involved in the nuclear fuels during the burn-up at the power nuclear reactors for burn-up levels of 33.000 MWd/th are considered. Graphs and data on the radioactivity variation with the cooling time and heat power of the irradiated fuel are presented. Likewise, the cycle of the fuel in light water reactors is presented and the alternatives for the nuclear waste management are discussed. A brief description of the management of the spent fuel as a high level nuclear waste is shown, explaining the reprocessing and giving data about the fission products and their radioactivities, which must be considered on the vitrification processes. On the final storage of the nuclear waste into depth geological burials, both alternatives are coincident. The countries supporting the reprocessing are indicated and the Spanish programm defined in the Plan Energetico Nacional (PEN) is shortly reviewed. (author) 8 figs., 4 tabs

  2. High Frequency Oscillatory Ventilation

    Directory of Open Access Journals (Sweden)

    AC Bryan

    1996-01-01

    Full Text Available High frequency oscillatory (HFO ventilation using low tidal volume and peak airway pressures is extremely efficient at eliminating carbon dioxide and raising pH in the newborn infant with acute respiratory failure. Improvement in oxygenation requires a strategy of sustained or repetitive inflations to 25 to 30 cm H2O in order to place the lung on the deflation limb of the pressure-volume curve. This strategy has also been shown to decrease the amount of secondary lung injury in animal models. Experience of the use of HFO ventilation as a rescue therapy as well as several published controlled trials have shown improved outcomes and a decrease in the use of extracorporeal membrane oxygenation when it has been used in newborns.

  3. High temperature metallic recuperator

    Science.gov (United States)

    Ward, M. E.; Solmon, N. G.; Smeltzer, C. E.

    1981-06-01

    An industrial 4.5 MM Btu/hr axial counterflow recuperator, fabricated to deliver 1600 F combustion air, was designed to handle rapid cyclic loading, a long life, acceptable costs, and a low maintenance requirement. A cost benefit anlysis of a high temperature waste heat recovery system utilizing the recurperator and components capable of 1600 F combustion air preheat shows that this system would have a payback period of less than two years. Fifteen companies and industrial associations were interviewed and expressed great interest in recuperation in large energy consuming industries. Determination of long term environmental effects on candidate recuperator tubing alloys was completed. Alloys found to be acceptable in the 2200 F flue gas environment of a steel billet reheat furnace, were identified.

  4. High pressure mechanical seal

    Science.gov (United States)

    Babel, Henry W. (Inventor); Anderson, Raymond H. (Inventor)

    1996-01-01

    A relatively impervious mechanical seal is formed between the outer surface of a tube and the inside surface of a mechanical fitting of a high pressure fluid or hydraulic system by applying a very thin soft metal layer onto the outer surface of the hard metal tube and/or inner surface of the hard metal fitting. The thickness of such thin metal layer is independent of the size of the tube and/or fittings. Many metals and alloys of those metals exhibit the requisite softness, including silver, gold, tin, platinum, indium, rhodium and cadmium. Suitably, the coating is about 0.0025 millimeters (0.10 mils) in thickness. After compression, the tube and fitting combination exhibits very low leak rates on the order or 10.sup.-8 cubic centimeters per second or less as measured using the Helium leak test.

  5. High energy physics

    International Nuclear Information System (INIS)

    Kernan, A.; Shen, B.C.; Ma, E.

    1997-01-01

    Hadron collider studies will focus on: (i) the search for the top quark with the newly installed D0 detector at the Fermilab Tevatron collider, (ii) the upgrade of the D0 detector to match the new main injector luminosity and (iii) R ampersand D on silicon microstrip tracking devices for the SSC. High statistics studies of Z 0 decay will continue with the OPAL detector at LEP. These studies will include a direct measurement of Z decay to neutrinos, the search for Higgs and heavy quark decays of Z. Preparations for the Large Scintillation Neutrino Detector (LSND) to measure neutrino oscillations at LAMPF will focus on data acquisition and testing of photomultiplier tubes. In the theoretical area E. Ma will concentrate on mass-generating radiative mechanisms for light quarks and leptons in renormalizable gauge field theories. J. Wudka's program includes a detailed investigation of the magnetic-flip approach to the solar neutrino

  6. High resolution ultrasonic densitometer

    International Nuclear Information System (INIS)

    Dress, W.B.

    1983-01-01

    The velocity of torsional stress pulses in an ultrasonic waveguide of non-circular cross section is affected by the temperature and density of the surrounding medium. Measurement of the transit times of acoustic echoes from the ends of a sensor section are interpreted as level, density, and temperature of the fluid environment surrounding that section. This paper examines methods of making these measurements to obtain high resolution, temperature-corrected absolute and relative density and level determinations of the fluid. Possible applications include on-line process monitoring, a hand-held density probe for battery charge state indication, and precise inventory control for such diverse fluids as uranium salt solutions in accountability storage and gasoline in service station storage tanks

  7. High temperature pipeline design

    Energy Technology Data Exchange (ETDEWEB)

    Greenslade, J.G. [Colt Engineering, Calgary, AB (Canada). Pipelines Dept.; Nixon, J.F. [Nixon Geotech Ltd., Calgary, AB (Canada); Dyck, D.W. [Stress Tech Engineering Inc., Calgary, AB (Canada)

    2004-07-01

    It is impractical to transport bitumen and heavy oil by pipelines at ambient temperature unless diluents are added to reduce the viscosity. A diluted bitumen pipeline is commonly referred to as a dilbit pipeline. The diluent routinely used is natural gas condensate. Since natural gas condensate is limited in supply, it must be recovered and reused at high cost. This paper presented an alternative to the use of diluent to reduce the viscosity of heavy oil or bitumen. The following two basic design issues for a hot bitumen (hotbit) pipeline were presented: (1) modelling the restart problem, and, (2) establishing the maximum practical operating temperature. The transient behaviour during restart of a high temperature pipeline carrying viscous fluids was modelled using the concept of flow capacity. Although the design conditions were hypothetical, they could be encountered in the Athabasca oilsands. It was shown that environmental disturbances occur when the fluid is cooled during shut down because the ground temperature near the pipeline rises. This can change growing conditions, even near deeply buried insulated pipelines. Axial thermal loads also constrain the design and operation of a buried pipeline as higher operating temperatures are considered. As such, strain based design provides the opportunity to design for higher operating temperature than allowable stress based design methods. Expansion loops can partially relieve the thermal stress at a given temperature. As the design temperature increase, there is a point at which above grade pipelines become attractive options, although the materials and welding procedures must be suitable for low temperature service. 3 refs., 1 tab., 10 figs.

  8. Galaxies at High Redshift

    Science.gov (United States)

    Bauer, F. E.

    2014-10-01

    Recent years have seen tremendous progress in finding and charactering star-forming galaxies at high redshifts across the electromagnetic spectrum, giving us a more complete picture of how galaxies evolve, both in terms of their stellar and gas content, as well as the growth of their central supermassive black holes. A wealth of studies now demonstrate that star formation peaked at roughly half the age of the Universe and drops precariously as we look back to very early times, and that their central monsters apparently growth with them. At the highest-redshifts, we are pushing the boundaries via deep surveys at optical, X-ray, radio wavelengths, and more recently using gamma-ray bursts. I will review some of our accomplishments and failures. Telescope have enabled Lyman break galaxies to be robustly identified, but the UV luminosity function and star formation rate density of this population at z = 6 - 8 seems to be much lower than at z = 2 - 4. High escape fractions and a large contribution from faint galaxies below our current detection limits would be required for star-forming galaxies to reionize the Universe. We have also found that these galaxies have blue rest-frame UV colours, which might indicate lower dust extinction at z > 5. There has been some spectroscopic confirmation of these Lyman break galaxies through Lyman-α emission, but the fraction of galaxies where we see this line drops at z > 7, perhaps due to the onset of the Gunn-Peterson effect (where the IGM is opaque to Lyman-α).

  9. High Purity Smelting Technology for Ultra-high Strength Steels

    Directory of Open Access Journals (Sweden)

    JIANG Zhouhua

    2017-12-01

    Full Text Available Ultra-high strength steel with high tensile strength, good toughness, high specific strength, modulus and other characteristics are widely used in aviation, aerospace and national defense and other fields. Ultra-high strength steel is preferred material for aircraft and aero-engines and other aviation equipments. The application of ultra-high strength steel represents a country's highest level of steel research and production, and it is also an important symbol of the development of national science and technology and national defense industry. The development and application of high purity smelting technology for manufacture of ultra-high strength steels at domestic and overseas is briefly reviewed in the paper, and then the control ability about the impurity elements such as S, P, O and N in typical ultra-high strength steels, and the research status and development trend of non-metallic inclusions control are discussed. The progress in research work of high purity smelting technology for ultra-high strength steels carried out by the authors in recent years has been introduced, it shows that the control level of impurity elements and non-metallic inclusion has been greatly improved, and it also creates a new route for China to manufacture the ultra-high strength steel with high alloy, especially with high purity for ultra-high strength stainless steel, bearing steel and gear steel. Finally, the development direction of high purity smelting technology of ultra-high strength steel in China is pointed out.

  10. FSU High Energy Physics

    Energy Technology Data Exchange (ETDEWEB)

    Prosper, Harrison B. [Florida State Univ., Tallahassee, FL (United States); Adams, Todd [Florida State Univ., Tallahassee, FL (United States); Askew, Andrew [Florida State Univ., Tallahassee, FL (United States); Berg, Bernd [Florida State Univ., Tallahassee, FL (United States); Blessing, Susan K. [Florida State Univ., Tallahassee, FL (United States); Okui, Takemichi [Florida State Univ., Tallahassee, FL (United States); Owens, Joseph F. [Florida State Univ., Tallahassee, FL (United States); Reina, Laura [Florida State Univ., Tallahassee, FL (United States); Wahl, Horst D. [Florida State Univ., Tallahassee, FL (United States)

    2014-12-01

    The High Energy Physics group at Florida State University (FSU), which was established in 1958, is engaged in the study of the fundamental constituents of matter and the laws by which they interact. The group comprises theoretical and experimental physicists, who sometimes collaborate on projects of mutual interest. The report highlights the main recent achievements of the group. Significant, recent, achievements of the group’s theoretical physicists include progress in making precise predictions in the theory of the Higgs boson and its associated processes, and in the theoretical understanding of mathematical quantities called parton distribution functions that are related to the structure of composite particles such as the proton. These functions are needed to compare data from particle collisions, such as the proton-proton collisions at the CERN Large Hadron Collider (LHC), with theoretical predictions. The report also describes the progress in providing analogous functions for heavy nuclei, which find application in neutrino physics. The report highlights progress in understanding quantum field theory on a lattice of points in space and time (an area of study called lattice field theory), the progress in constructing several theories of potential new physics that can be tested at the LHC, and interesting new ideas in the theory of the inflationary expansion of the very early universe. The focus of the experimental physicists is the Compact Muon Solenoid (CMS) experiment at CERN. The report, however, also includes results from the D0 experiment at Fermilab to which the group made numerous contributions over a period of many years. The experimental group is particularly interested in looking for new physics at the LHC that may provide the necessary insight to extend the standard model (SM) of particle physics. Indeed, the search for new physics is the primary task of contemporary particle physics, one motivated by the need to explain certain facts, such as the

  11. Neutron diffraction under high pressure and high temperature

    International Nuclear Information System (INIS)

    Komatsu, Kazuki

    2010-01-01

    Neutron diffraction study under high pressure and high temperature is reviewed from the technical point of view. Particularly, cell assembly for the high-PT neutron diffraction using a Paris-Edinburgh cell with the temperature calibration by neutron resonance spectroscopy is introduced. Notes on the errors relevant to high pressure and high temperature experiments in both monochromatic angle dispersive and time-of-flight methods are also discussed. (author)

  12. Highly Anisotropic Conductors.

    Science.gov (United States)

    Wan, Jiayu; Song, Jianwei; Yang, Zhi; Kirsch, Dylan; Jia, Chao; Xu, Rui; Dai, Jiaqi; Zhu, Mingwei; Xu, Lisha; Chen, Chaoji; Wang, Yanbin; Wang, Yilin; Hitz, Emily; Lacey, Steven D; Li, Yongfeng; Yang, Bao; Hu, Liangbing

    2017-11-01

    Composite materials with ordered microstructures often lead to enhanced functionalities that a single material can hardly achieve. Many biomaterials with unusual microstructures can be found in nature; among them, many possess anisotropic and even directional physical and chemical properties. With inspiration from nature, artificial composite materials can be rationally designed to achieve this anisotropic behavior with desired properties. Here, a metallic wood with metal continuously filling the wood vessels is developed, which demonstrates excellent anisotropic electrical, thermal, and mechanical properties. The well-aligned metal rods are confined and separated by the wood vessels, which deliver directional electron transport parallel to the alignment direction. Thus, the novel metallic wood composite boasts an extraordinary anisotropic electrical conductivity (σ || /σ ⊥ ) in the order of 10 11 , and anisotropic thermal conductivity (κ || /κ ⊥ ) of 18. These values exceed the highest reported values in existing anisotropic composite materials. The anisotropic functionality of the metallic wood enables it to be used for thermal management applications, such as thermal insulation and thermal dissipation. The highly anisotropic metallic wood serves as an example for further anisotropic materials design; other composite materials with different biotemplates/hosts and fillers can achieve even higher anisotropic ratios, allowing them to be implemented in a variety of applications. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  13. Chaos at High School

    Directory of Open Access Journals (Sweden)

    Tamás Meszéna

    2017-04-01

    Full Text Available We are faced with chaotic processes in many segments of our life: meteorology, environmental pollution, financial and economic processes, sociology, mechanics, electronics, biology, chemistry. The spreading of high-performance computers and the development of simulation methods made the examination of these processes easily available. Regular, periodic motions (pendulum, harmonic oscillatory motion, bouncing ball, as taught at secondary level, become chaotic even due minor changes. If it is true that the most considerable achievements of twentieth century physics were the theory of relativity, quantum mechanics and chaos theory, then it is presumably time to think about, examine and test how and to what extent chaos can be presented to the students. Here I would like to introduce a 12 lesson long facultative curriculum framework on chaos designed for students aged seventeen. The investigation of chaos phenomenon in this work is based on a freeware, “Dynamics Solver”. This software, with some assistance from the teacher, is suitable for classroom use at secondary level.

  14. HIGH TEMPERATURE VACUUM MIXER

    Directory of Open Access Journals (Sweden)

    E. D. Chertov

    2015-01-01

    Full Text Available The work is devoted to the creation of a new type of mixer to produce homogeneous mixtures of dissimilar materials applied to recycling of housing and communal services waste. The article describes the design of a dual-chamber device of the original high-temperature vacuum mixer, there investigated the processes occurring in the chambers of such devices. The results of theoretical and experimental research of the process of mixing recycled polyethylene with a mixture of "grinded food waste – Eco wool” are presented. The problem of the optimum choice of bending the curvilinear blades in the working volume of the seal, which is achieved by setting their profile in the form of involute arc of several circles of different radii, is examined . The dependences, allowing to define the limits of the changes of the main mode parameters the angular velocity of rotation of the working body of the mixer using two ways of setting the profile of the curvilinear blade mixer are obtained. Represented design of the mixer is proposed to use for a wide range of tasks associated with the mixing of the components with a strongly pronounced difference of physic al chemical properties and, in particular, in the production of composites out of housing and communal services waste.

  15. Flexible high speed CODEC

    Science.gov (United States)

    Wernlund, James V.

    1993-01-01

    HARRIS, under contract with NASA Lewis, has developed a hard decision BCH (Bose-Chaudhuri-Hocquenghem) triple error correcting block CODEC ASIC, that can be used in either a bursted or continuous mode. the ASIC contains both encoder and decoder functions, programmable lock thresholds, and PSK related functions. The CODEC provides up to 4 dB of coding gain for data rates up to 300 Mbps. The overhead is selectable from 7/8 to 15/16 resulting in minimal band spreading, for a given BER. Many of the internal calculations are brought out enabling the CODEC to be incorporated in more complex designs. The ASIC has been tested in BPSK, QPSK and 16-ary PSK link simulators and found to perform to within 0.1 dB of theory for BER's of 10(exp -2) to 10(exp -9). The ASIC itself, being a hard decision CODEC, is not limited to PSK modulation formats. Unlike most hard decision CODEC's, the HARRIS CODEC doesn't upgrade BER performance significantly at high BER's but rather becomes transparent.

  16. High Speed Ice Friction

    Science.gov (United States)

    Seymour-Pierce, Alexandra; Sammonds, Peter; Lishman, Ben

    2014-05-01

    Many different tribological experiments have been run to determine the frictional behaviour of ice at high speeds, ostensibly with the intention of applying results to everyday fields such as winter tyres and sports. However, experiments have only been conducted up to linear speeds of several metres a second, with few additional subject specific studies reaching speeds comparable to these applications. Experiments were conducted in the cold rooms of the Rock and Ice Physics Laboratory, UCL, on a custom built rotational tribometer based on previous literature designs. Preliminary results from experiments run at 2m/s for ice temperatures of 271 and 263K indicate that colder ice has a higher coefficient of friction, in accordance with the literature. These results will be presented, along with data from further experiments conducted at temperatures between 259-273K (in order to cover a wide range of the temperature dependent behaviour of ice) and speeds of 2-15m/s to produce a temperature-velocity-friction map for ice. The effect of temperature, speed and slider geometry on the deformation of ice will also be investigated. These speeds are approaching those exhibited by sports such as the luge (where athletes slide downhill on an icy track), placing the tribological work in context.

  17. High Power Coax Window

    International Nuclear Information System (INIS)

    Neubauer, M.L.; Dudas, A.; Sah, R.; Elliott, T.S.; Rimmer, R.A.; Stirbet, M.

    2010-01-01

    A superconducting RF (SRF) power coupler capable of handling 500 kW CW RF power is required for present and future storage rings and linacs. There are over 35 coupler designs for SRF cavities ranging in frequency from 325 to 1500 MHz. Coupler windows vary from cylinders to cones to disks, and RF power couplers are limited by the ability of ceramic windows to withstand the stresses due to heating and mechanical flexure. We propose a novel robust co-axial SRF coupler design which uses compressed window technology. This technology will allow the use of highly thermally conductive materials for cryogenic windows. Using compressed window techniques on disk co-axial windows will make significant improvements in the power handling of SRF couplers. We present the bench test results of two window assemblies back to back, as well as individual window VSWR in EIA3.125 coax. A vacuum test assembly was made and the windows baked out at 155C. The processes used to build windows is scalable to larger diameter coax and to higher power levels.

  18. High-Rise Zhivago

    Directory of Open Access Journals (Sweden)

    Elena Siemens

    2016-02-01

    Full Text Available This paper discusses the Taganka Theatre’s production of Pasternak’s Doctor Zhivago, staged in a remote Moscow suburb. Performed in a Soviet-built palace of culture, the show radically reinterpretsZhivago, transforming it from an intensely personal to a collective narrative. Drawing on a chapter from my book Theatre in Passing: A Moscow Photo-Diary (Intellect 2011, the paper refers to Marvin Carlson, who argues that theatre buildings and their locations greatly impact the overall meaning of a show. Citing evidence provided by cultural theorists, architectural critics, as well as authors and artists, I expand on my earlier discussion of suburbs – a fertile subject attracting a wealth of contradictory opinions. I illustrate my discussion with images of high-rises inspired by the avant-garde photographer Alexander Rodchenko, and pictures of soup cans and cases of Coca-Cola – my tribute to Andy Warhol, who, like Rodchenko, rejected the old in favour of the new. I conclude with a nostalgic shot of a single-family dwelling, reminiscent of the spaces depicted in Pasternak.

  19. High energy physics

    International Nuclear Information System (INIS)

    Kernan, A.; Shen, B.C.; Ma, E.

    1997-01-01

    This proposal is for the continuation of the High Energy Physics Program at the University of California, Riverside. In 1990, we will concentrate on analysis of LEP data from the OPAL detector. We expect to record 10 5 Z's by the end of 1989 and 10 6 in 1990. This data will be used to measure the number of quark-lepton families in the universe. In the second half of 1990 we will also be occupied with the installation of the D-Zero detector in the Tevatron Collider and the preparation of software for the 1991 run. A new initiative made possible by generous university support is a laboratory for detector development at UCR. The focus will be on silicon strip tracking detectors both for the D-Zero upgrade and for SSC physics. The theory program will pursue further various mass-generating radiative mechanisms for understanding small quark and lepton masses as well as some novel phenomenological aspects of supersymmetry

  20. Thermostating highly confined fluids.

    Science.gov (United States)

    Bernardi, Stefano; Todd, B D; Searles, Debra J

    2010-06-28

    In this work we show how different use of thermostating devices and modeling of walls influence the mechanical and dynamical properties of confined nanofluids. We consider a two dimensional fluid undergoing Couette flow using nonequilibrium molecular dynamics simulations. Because the system is highly inhomogeneous, the density shows strong fluctuations across the channel. We compare the dynamics produced by applying a thermostating device directly to the fluid with that obtained when the wall is thermostated, considering also the effects of using rigid walls. This comparison involves an analysis of the chaoticity of the fluid and evaluation of mechanical properties across the channel. We look at two thermostating devices with either rigid or vibrating atomic walls and compare them with a system only thermostated by conduction through vibrating atomic walls. Sensitive changes are observed in the xy component of the pressure tensor, streaming velocity, and density across the pore and the Lyapunov localization of the fluid. We also find that the fluid slip can be significantly reduced by rigid walls. Our results suggest caution in interpreting the results of systems in which fluid atoms are thermostated and/or wall atoms are constrained to be rigid, such as, for example, water inside carbon nanotubes.

  1. Diagnosis of High Blood Pressure

    Medline Plus

    Full Text Available ... are two main types of high blood pressure: primary and secondary high blood pressure. Primary High Blood Pressure Primary, ... plan based on whether you were diagnosed with primary or secondary high blood pressure and if there is a ...

  2. High density matter at RHIC

    Indian Academy of Sciences (India)

    ken. Color-superconducting and other phases may exist at high baryon density and low temperature [3], whereas at high temperature the quarks and gluons are de- confined and chiral symmetry is restored. The early universe descended from high. T at extremely small μB. Neutron star cores have high μB and very low T.

  3. High-efficiency CARM

    Energy Technology Data Exchange (ETDEWEB)

    Bratman, V.L.; Kol`chugin, B.D.; Samsonov, S.V.; Volkov, A.B. [Institute of Applied Physics, Nizhny Novgorod (Russian Federation)

    1995-12-31

    The Cyclotron Autoresonance Maser (CARM) is a well-known variety of FEMs. Unlike the ubitron in which electrons move in a periodical undulator field, in the CARM the particles move along helical trajectories in a uniform magnetic field. Since it is much simpler to generate strong homogeneous magnetic fields than periodical ones for a relatively low electron energy ({Brit_pounds}{le}1-3 MeV) the period of particles` trajectories in the CARM can be sufficiently smaller than in the undulator in which, moreover, the field decreases rapidly in the transverse direction. In spite of this evident advantage, the number of papers on CARM is an order less than on ubitron, which is apparently caused by the low (not more than 10 %) CARM efficiency in experiments. At the same time, ubitrons operating in two rather complicated regimes-trapping and adiabatic deceleration of particles and combined undulator and reversed guiding fields - yielded efficiencies of 34 % and 27 %, respectively. The aim of this work is to demonstrate that high efficiency can be reached even for a simplest version of the CARM. In order to reduce sensitivity to an axial velocity spread of particles, a short interaction length where electrons underwent only 4-5 cyclotron oscillations was used in this work. Like experiments, a narrow anode outlet of a field-emission electron gun cut out the {open_quotes}most rectilinear{close_quotes} near-axis part of the electron beam. Additionally, magnetic field of a small correcting coil compensated spurious electron oscillations pumped by the anode aperture. A kicker in the form of a sloping to the axis frame with current provided a control value of rotary velocity at a small additional velocity spread. A simple cavity consisting of a cylindrical waveguide section restricted by a cut-off waveguide on the cathode side and by a Bragg reflector on the collector side was used as the CARM-oscillator microwave system.

  4. High temperature materials and mechanisms

    CERN Document Server

    2014-01-01

    The use of high-temperature materials in current and future applications, including silicone materials for handling hot foods and metal alloys for developing high-speed aircraft and spacecraft systems, has generated a growing interest in high-temperature technologies. High Temperature Materials and Mechanisms explores a broad range of issues related to high-temperature materials and mechanisms that operate in harsh conditions. While some applications involve the use of materials at high temperatures, others require materials processed at high temperatures for use at room temperature. High-temperature materials must also be resistant to related causes of damage, such as oxidation and corrosion, which are accelerated with increased temperatures. This book examines high-temperature materials and mechanisms from many angles. It covers the topics of processes, materials characterization methods, and the nondestructive evaluation and health monitoring of high-temperature materials and structures. It describes the ...

  5. High Ra, high Pr convection with viscosity gradients

    Indian Academy of Sciences (India)

    First page Back Continue Last page Overview Graphics. High Ra, high Pr convection with viscosity gradients. Weak upward flow through mesh. Top fluid more viscous. Unstable layer Instability Convection.

  6. High regression rate, high density hybrid fuels, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — This SBIR program will investigate high energy density novel nanofuels combined with high density binders for use with an N2O oxidizer. Terves has developed...

  7. Highly Accurate Sensor for High-Purity Oxygen Determination Project

    Data.gov (United States)

    National Aeronautics and Space Administration — In this STTR effort, Los Gatos Research (LGR) and the University of Wisconsin (UW) propose to develop a highly-accurate sensor for high-purity oxygen determination....

  8. Turning High-Poverty Schools into High-Performing Schools

    Science.gov (United States)

    Parrett, William H.; Budge, Kathleen

    2012-01-01

    If some schools can overcome the powerful and pervasive effects of poverty to become high performing, shouldn't any school be able to do the same? Shouldn't we be compelled to learn from those schools? Although schools alone will never systemically eliminate poverty, high-poverty, high-performing (HP/HP) schools take control of what they can to…

  9. High Average Power, High Energy Short Pulse Fiber Laser System

    Energy Technology Data Exchange (ETDEWEB)

    Messerly, M J

    2007-11-13

    Recently continuous wave fiber laser systems with output powers in excess of 500W with good beam quality have been demonstrated [1]. High energy, ultrafast, chirped pulsed fiber laser systems have achieved record output energies of 1mJ [2]. However, these high-energy systems have not been scaled beyond a few watts of average output power. Fiber laser systems are attractive for many applications because they offer the promise of high efficiency, compact, robust systems that are turn key. Applications such as cutting, drilling and materials processing, front end systems for high energy pulsed lasers (such as petawatts) and laser based sources of high spatial coherence, high flux x-rays all require high energy short pulses and two of the three of these applications also require high average power. The challenge in creating a high energy chirped pulse fiber laser system is to find a way to scale the output energy while avoiding nonlinear effects and maintaining good beam quality in the amplifier fiber. To this end, our 3-year LDRD program sought to demonstrate a high energy, high average power fiber laser system. This work included exploring designs of large mode area optical fiber amplifiers for high energy systems as well as understanding the issues associated chirped pulse amplification in optical fiber amplifier systems.

  10. Ultra high vacuum broad band high power microwave window

    Science.gov (United States)

    Nguyen-Tuong, Viet; Dylla, III, Henry Frederick

    1997-01-01

    An improved high vacuum microwave window has been developed that utilizes high density polyethylene coated on two sides with SiOx, SiNx, or a combination of the two. The resultant low dielectric and low loss tangent window creates a low outgassing, low permeation seal through which broad band, high power microwave energy may be passed. No matching device is necessary and the sealing technique is simple. The features of the window are broad band transmission, ultra-high vacuum compatibility with a simple sealing technique, low voltage standing wave ratio, high power transmission and low cost.

  11. High Efficiency Power Converter for Low Voltage High Power Applications

    DEFF Research Database (Denmark)

    Nymand, Morten

    The topic of this thesis is the design of high efficiency power electronic dc-to-dc converters for high-power, low-input-voltage to high-output-voltage applications. These converters are increasingly required for emerging sustainable energy systems such as fuel cell, battery or photo voltaic based......, and remote power generation for light towers, camper vans, boats, beacons, and buoys etc. A review of current state-of-the-art is presented. The best performing converters achieve moderately high peak efficiencies at high input voltage and medium power level. However, system dimensioning and cost are often...

  12. High Temperature Electrostrictive Ceramics Project

    Data.gov (United States)

    National Aeronautics and Space Administration — TRS Technologies proposes to develop high temperature electrostrictors from bismuth-based ferroelectrics. These materials will exhibit high strain and low loss in...

  13. Diagnosis of High Blood Pressure

    Medline Plus

    Full Text Available ... treatment plans for high blood pressure that include lifelong lifestyle changes and medicines to control high blood ... Managing and coping with stress To help make lifelong lifestyle changes, try making one healthy lifestyle change ...

  14. High Blood Pressure - Multiple Languages

    Science.gov (United States)

    ... High Blood Pressure (Hypertension) - 简体中文 (Chinese, Simplified (Mandarin dialect)) Bilingual PDF Health Information Translations Chinese, Traditional (Cantonese dialect) (繁體中文) Expand Section High ...

  15. Diagnosis of High Blood Pressure

    Medline Plus

    Full Text Available ... Card can help you track your blood pressure. Pregnancy Planning High blood pressure can cause problems for ... control your blood pressure before and during the pregnancy. Some women develop high blood pressure during pregnancy. ...

  16. High Thermal Conductivity Composite Structures

    National Research Council Canada - National Science Library

    Bootle, John

    1999-01-01

    ... applications and space based radiators. The advantage of this material compared to competing materials that it can be used to fabricate high strength, high thermal conductivity, relatively thin structures less than 0.050" thick...

  17. Diagnosis of High Blood Pressure

    Medline Plus

    Full Text Available ... of physical activity Drinking too much alcohol Stress Family History A family history of high blood pressure raises the risk ... for high blood pressure and may run in families. Genetic causes of this condition are why family ...

  18. Assessing Highly-Creative Ability

    Science.gov (United States)

    Cowdroy, Rob; de Graaff, Erik

    2005-01-01

    This paper presents a psychological perspective of the educational dilemma of assessing highly (high-level) creative ability (with some connections to contemporary philosophical debate). Assessment of highly-creative ability is a topic of longstanding debate involving questions of what constitutes creativity; whether the creative mental process is…

  19. High average power supercontinuum sources

    Indian Academy of Sciences (India)

    The physical mechanisms and basic experimental techniques for the creation of high average spectral power supercontinuum sources is briefly reviewed. We focus on the use of high-power ytterbium-doped fibre lasers as pump sources, and the use of highly nonlinear photonic crystal fibres as the nonlinear medium.

  20. What Is High Blood Pressure?

    Science.gov (United States)

    ... Disease Venous Thromboembolism Aortic Aneurysm More What is High Blood Pressure? Updated:Feb 27,2018 First, let’s define high ... resources . This content was last reviewed October 2016. High Blood Pressure • Home • Get the Facts About HBP Introduction What ...

  1. High intensity circular proton accelerators

    International Nuclear Information System (INIS)

    Craddock, M.K.

    1987-12-01

    Circular machines suitable for the acceleration of high intensity proton beams include cyclotrons, FFAG accelerators, and strong-focusing synchrotrons. This paper discusses considerations affecting the design of such machines for high intensity, especially space charge effects and the role of beam brightness in multistage accelerators. Current plans for building a new generation of high intensity 'kaon factories' are reviewed. 47 refs

  2. Advances in high temperature chemistry

    CERN Document Server

    Eyring, Leroy

    1969-01-01

    Advances in High Temperature Chemistry, Volume 2 covers the advances in the knowledge of the high temperature behavior of materials and the complex and unfamiliar characteristics of matter at high temperature. The book discusses the dissociation energies and free energy functions of gaseous monoxides; the matrix-isolation technique applied to high temperature molecules; and the main features, the techniques for the production, detection, and diagnosis, and the applications of molecular beams in high temperatures. The text also describes the chemical research in streaming thermal plasmas, as w

  3. High-Performance Data Converters

    DEFF Research Database (Denmark)

    Steensgaard-Madsen, Jesper

    Novel techniques for multi-bit oversampled data conversion are described. State-of-the-art oversampled data converters are analyzed, leading to the conclusion that their performance is limited mainly by low-resolution signal representation. To increase the resolution, high-performance, high......, because that requires a high-resolution loop quantizer which introduces only a small delay. Generally, it is not acceptable to design the loop quantizer as a high-resolution flash quantizer because they require a large chip area and high power consumption. Pipeline techniques are proposed to circumvent...

  4. Concept for a new high resolution high intensity diffractometer

    Energy Technology Data Exchange (ETDEWEB)

    Stuhr, U. [Paul Scherrer Inst. (PSI), Villigen (Switzerland)

    1997-09-01

    A concept of a new time-of-flight powder-diffractometer for a thermal neutral beam tube at SINQ is presented. The design of the instrument optimises the contradictory conditions of high intensity and high resolution. The high intensity is achieved by using many neutron pulses simultaneously. By analysing the time-angle-pattern of the detected neutrons an assignment of the neutrons to a single pulse is possible. (author) 3 figs., tab., refs.

  5. High-Temperature Piezoelectric Sensing

    Science.gov (United States)

    Jiang, Xiaoning; Kim, Kyungrim; Zhang, Shujun; Johnson, Joseph; Salazar, Giovanni

    2014-01-01

    Piezoelectric sensing is of increasing interest for high-temperature applications in aerospace, automotive, power plants and material processing due to its low cost, compact sensor size and simple signal conditioning, in comparison with other high-temperature sensing techniques. This paper presented an overview of high-temperature piezoelectric sensing techniques. Firstly, different types of high-temperature piezoelectric single crystals, electrode materials, and their pros and cons are discussed. Secondly, recent work on high-temperature piezoelectric sensors including accelerometer, surface acoustic wave sensor, ultrasound transducer, acoustic emission sensor, gas sensor, and pressure sensor for temperatures up to 1,250 °C were reviewed. Finally, discussions of existing challenges and future work for high-temperature piezoelectric sensing are presented. PMID:24361928

  6. High permittivity gate dielectric materials

    CERN Document Server

    2013-01-01

    "The book comprehensively covers all the current and the emerging areas of the physics and the technology of high permittivity gate dielectric materials, including, topics such as MOSFET basics and characteristics, hafnium-based gate dielectric materials, Hf-based gate dielectric processing, metal gate electrodes, flat-band and threshold voltage tuning, channel mobility, high-k gate stack degradation and reliability, lanthanide-based high-k gate stack materials, ternary hafnia and lanthania based high-k gate stack films, crystalline high-k oxides, high mobility substrates, and parameter extraction. Each chapter begins with the basics necessary for understanding the topic, followed by a comprehensive review of the literature, and ultimately graduating to the current status of the technology and our scientific understanding and the future prospects."

  7. High-Temperature Piezoelectric Sensing

    Directory of Open Access Journals (Sweden)

    Xiaoning Jiang

    2013-12-01

    Full Text Available Piezoelectric sensing is of increasing interest for high-temperature applications in aerospace, automotive, power plants and material processing due to its low cost, compact sensor size and simple signal conditioning, in comparison with other high-temperature sensing techniques. This paper presented an overview of high-temperature piezoelectric sensing techniques. Firstly, different types of high-temperature piezoelectric single crystals, electrode materials, and their pros and cons are discussed. Secondly, recent work on high-temperature piezoelectric sensors including accelerometer, surface acoustic wave sensor, ultrasound transducer, acoustic emission sensor, gas sensor, and pressure sensor for temperatures up to 1,250 °C were reviewed. Finally, discussions of existing challenges and future work for high-temperature piezoelectric sensing are presented.

  8. Programmable high crystallinity carbon patterns

    Science.gov (United States)

    Wang, Xuewen; Wang, Hong; Gu, Yang; Fu, Wei; Zheng, Lu; Liu, Guowei; He, Yongmin; Long, Yi; Zhao, Wu; Zhang, Jie; Zhang, Ting; Liu, Zheng

    2017-06-01

    Carbon nanomaterials such as carbon nanotube and graphene are promising candidates for next-generation flexible electronics. However, the practical application of carbon electronics requires controlled fabrication of those materials with micro-patterned structures on flexible substrate at wafer-scale and low cost. Inspiring from the conventional photolithography process and pyrolysis of photoresist, herein, we demonstrate the synthesis of high-quality micro-patterned high crystallinity carbon. The method employed pre-patterned pyrolyzed photoresist as carbon precursors, in order to minimize the mobility of carbon during the high temperature growth, which results into high quality carbon patterns with a lateral resolution up to ~2 µm. The flexible carbon electronics are demonstrated by transferring the as-patterned high crystallinity carbon patterns to the flexible substrate, and showing asymmetric tensile-compressive response with high output resolution. These results will pave the way to the next-generation carbon-based flexible electronics and mechanical sensors.

  9. Another Innovation from High Tech High--Embedded Teacher Training

    Science.gov (United States)

    Griswold, Janie; Riordan, Rob

    2016-01-01

    High Tech High School's teaching internship program blends on-the-job work with classroom theory. Interns spend two years working as full teachers as they take courses. The program serves three large purposes: Train new teachers and build capacity in the HTH organization; train teachers in and beyond HTH for success in a wide range of contexts;…

  10. Insulin Resistance and Adipocytokine Levels in High Fat High ...

    African Journals Online (AJOL)

    The main objective of this study was to investigate the effects of high fat high fructose (HF/HFr) diet on the onset of the characteristics of the metabolic syndrome and the levels of some adipocytokines in growing male and female rats. Also we aimed to study the possible protective effects of cinnamon (CN) against HF/HFr diet ...

  11. Decay properties of high-lying single-particles modes

    NARCIS (Netherlands)

    Beaumel, D; Fortier, S; Gales, S; Guillot, J; LangevinJoliot, H; Laurent, H; Maison, JM; Vernotte, J; Bordewijck, J; Brandenburg, S; Krasznahorkay, A; Crawley, GM; Massolo, CP; Renteria, M; Khendriche, A

    1996-01-01

    The neutron decay of high-lying single-particle states in Ni-64, Zr-90, Sn-120 and (208)pb excited by means of the (alpha,He-3) reaction has been investigated at 120 MeV incident energy using the multidetector EDEN. The characteristics of this reaction are studied using inclusive spectra and angular

  12. High-voltage high-current triggering vacuum switch

    International Nuclear Information System (INIS)

    Alferov, D.F.; Bunin, R.A.; Evsin, D.V.; Sidorov, V.A.

    2012-01-01

    Experimental investigations of switching and breaking capacities of the new high current triggered vacuum switch (TVS) are carried out at various parameters of discharge current. It has been shown that the high current triggered vacuum switch TVS can switch repeatedly a current from units up to ten kiloampers with duration up to ten millisecond [ru

  13. Dosimetry of high energy radiation

    CERN Document Server

    Sahare, P D

    2018-01-01

    High energy radiation is hazardous to living beings and a threat to mankind. The correct estimation of the high energy radiation is a must and a single technique may not be very successful. The process of estimating the dose (the absorbed energy that could cause damages) is called dosimetry. This book covers the basic technical knowledge in the field of radiation dosimetry. It also makes readers aware of the dangers and hazards of high energy radiation.

  14. Ultra High Vacuum Sputtering System

    Science.gov (United States)

    1991-07-25

    NO. NO. Washington, D.C. 20332-6448 E.. 1,1. T IT LE (Incirot Securi ty Ciassificalion) (U L t ra High Vacuum Spattering System _1__ 12. PERSONAL...ABSTRACT (Continue on reuerse it necessary and identify by bioc, number) This grant provided for the purchase of an ultra high vacuum sputtering system, for...FOR GRANT FROM DEFENSE UNIVERSITY RESEARCH INSTRUMENTATION PROGRAM Grant no. AFOSR-89-0138 Date Submitted: 27 July, 1991 Title: Ultra High Vacuum Sputtering

  15. High energy neutrinos from GRBs

    CERN Document Server

    De Paolis, F; Orlando, D; Perrone, L

    2001-01-01

    It is by now recognized that GRBs can accelerate protons to relativistic energies and that high density media may be present nearby the source. We compute the high-energy gamma-ray and neutrino fluxes from the decay of pions produced through the interaction of accelerated protons with nucleons in the surrounding medium. Then, we estimate the flux of high-energy muons induced on a detector by upward-going neutrinos interacting through charge current processes with the surrounding matter.

  16. High n ballooning modes in highly elongated tokamaks

    International Nuclear Information System (INIS)

    An, C.H.; Bateman, G.

    1980-02-01

    An analytic study of stability against high n ballooning modes in highly elongated axisymmetric plasmas is presented and compared with computational results. From the equation for the marginal pressure gradient, it is found that the local shear plays an important role on the stability of elongated and shifted plasma, and that high elongation deteriorates the stability by decreasing the stabilizing effects of field line bending and local shear. The net contribution of the local shear to stability decreases with elongation and shift for strongly ballooning modes (eigenfunctions strongly localized near the outer edge of the toroidal flux surfaces) but increases for interchange modes (eigenfunctions more uniform along the flux surfaces). The computational study of high n ballooning modes in a highly elongated plasma reveals that lowering the aspect ratio and broadening the pressure profile enhance the marginal beta for β/sub p/ less than unity but severely reduce the marginal beta for β/sub p/ larger than unity

  17. High-brightness electron injectors

    International Nuclear Information System (INIS)

    Sheffield, R.L.

    1987-01-01

    Free-electron laser (FEL) oscillators and synchrotron light sources require pulse trains of high peak brightness and, in some applications, high-average power. Recent developments in the technology of photoemissive and thermionic electron sources in rf cavities for electron-linac injector applications offer promising advances over conventional electron injectors. Reduced emittance growth in high peak-current electron injectors may be achieved by using high field strengths and by linearizing the radial component of the cavity electric field at the expense of lower shunt impedance

  18. Gamma dosimetry of high doses

    International Nuclear Information System (INIS)

    Martinez C, T.; Galvan G, A.; Canizal, G.

    1991-01-01

    The gamma dosimetry of high doses is problematic in almost all the classic dosemeters either based on the thermoluminescence, electric, chemical properties, etc., because they are saturated to very high dose and they are no longer useful. This work carries out an investigation in the interval of high doses. The solid system of heptahydrate ferrous sulfate, can be used as solid dosemeter of routine for high doses of radiation. The proposed method is simple, cheap and it doesn't require sophisticated spectrophotometers or spectrometers but expensive and not common in some laboratories

  19. High Temperature Superconductor Resonator Detectors

    Data.gov (United States)

    National Aeronautics and Space Administration — High Temperature Superconductor (HTS) infrared detectors were studied for years but never matured sufficiently for infusion into instruments. Several recent...

  20. Brain Food at High Altitude.

    Science.gov (United States)

    Jain, Vishal

    2016-01-01

    Scenic view at high altitude is a pleasure to the eyes, but it has some shortcoming effects as well. High altitude can be divided into different categories, i.e., high altitude (3000-5000 ft), very high altitude (5000-8000 ft), and extreme altitude (above 8000 ft). Much of the population resides at high altitude, and others go there for tourism. Military personnel are also posted there to defend boundaries. As we ascent to high altitude, partial pressure of oxygen reduces, whereas concentration remains the same; this reduces the availability of oxygen to different body parts. This pathophysiological condition is known as hypobaric hypoxia (HH) which leads to oxidative stress and further causes cognitive dysfunction in some cases. Hypoxia causes neurodegeneration in different brain regions; however, the hippocampus is found to be more prone in comparison to other brain regions. As the hippocampus is affected most, therefore, spatial memory is impaired most during such condition. This chapter will give a brief review of the damaging effect of high altitude on cognition and also throw light on possible herbal interventions at high altitude, which can improve cognitive performance as well as provide protection against the deteriorating effect of hypobaric hypoxia at high altitude.

  1. Fabrication and surface characterization of photopatterned encapsulated micromagnets for microrobotics and microfluidics applications

    Science.gov (United States)

    Li, Hui; Leachman, William; Kershaw, Joe

    2016-11-01

    In this paper, encapsulated micromagnets with magnetic core surrounded by pure SU-8 were fabricated utilizing multilayer photolithography with a middle NdFeB magnetic composite layer. Various geometries of micromagnets were fabricated with high density magnetic core and high resolution features, showing magnetically response while still being biocompatible and chemically resistant and making them suitable for a wide range of microrobotics and microfluidics applications. Especially, crescent and C-channel micromagnets showed potential of microtransportation devices because of their interior reservoirs. Surface characterization of the micromagnets was conducted using closed-form solutions derived from the general biplanar surface characterization method. The fabrication method was evaluated and the process errors were found less than 1%.

  2. High power switching and other high power devices

    Science.gov (United States)

    Gundersen, Martin

    1992-09-01

    High power thyratrons and devices such as high power microwave sources have cathode-related performance limits. Research is described of a simple, robust 'super-emissive' cathode that produces greater than 10,000 A/sq cm from a macroscopic area (approx. 1 sq cm), and operates with a low pressure (approx. 0.1 torr), spatially uniform glow plasma (density greater than 1015 cu cm). The cathode also can operate as a hollow cathode, and is at the heart of the operation of the pseudospark and back-lighted thyratron. The physics of this hollow and super-emissive cathode is very rich. The hollow cathode geometry traps electrons in the hollow cathode backspace. The lifetime of these electrons enables them to ionize a spatially homogeneous high density glow, and this hollow cathode mode of operation is responsible for certain types of electron and ion beam behavior. A plasma cathode sheath that is formed during this phase leads to super-emissive behavior, which is responsible for high current emission. Super-emissive cathode thyratron-type switches (with higher peak current, voltage, di/dt) being developed for pulsed power switching of lasers, accelerators, high current and high coulomb transfer, Marx bank operation, transfer of technology to commercial applications, high current electron beams, and millimeter wave generation (1 to 100 GHz) are described.

  3. Project Synopsis for High School/High Tech

    Science.gov (United States)

    1997-01-01

    To help increase the diversity of workers at NASA centers it is necessary to provide students with disabilities the opportunities to explore careers in high technology. HIGH SCHOOL/HIGH TECH, an enrichment program, pioneered at Goddard Space Flight Center, successfully introduces students with disabilities to high tech careers. This community-based partnership serves as a model for three additional NASA sites-Ames Research Center, Johnson Space Flight Center, and Lewis Research Center. For a three year period beginning August 15, 1995, provide financial and technical support to a local agency in each NASA center area which serves persons with disabilities to enable a High School/High Tech program to develop and stand alone. Each project will develop a basis of cooperation with Ames, Johnson, and Lewis as well as a variety of community groups including the public schools, high tech employers, post-secondary education and training programs, rehabilitation agencies, and community economic development organizations. Throughout the startup period and thereafter, local youths with disabilities will have early exposure to professions in mathematics, science, and technology-related fields. This exposure will be multifaceted to insure adequate opportunity for realistic career exploration so these youths have an opportunity to test their interests and abilities. The exposure will be presented in the most supportive environment that is feasible.

  4. High Energy Density Sciences with High Power Lasers at SACLA

    Science.gov (United States)

    Kodama, Ryosuke

    2013-10-01

    One of the interesting topics on high energy density sciences with high power lasers is creation of extremely high pressures in material. The pressures of more than 0.1 TPa are the energy density corresponding to the chemical bonding energy, resulting in expectation of dramatic changes in the chemical reactions. At pressures of more than TPa, most of material would be melted on the shock Hugoniot curve. However, if the temperature is less than 1eV or lower than a melting point at pressures of more than TPa, novel solid states of matter must be created through a pressured phase transition. One of the interesting materials must be carbon. At pressures of more than TPa, the diamond structure changes to BC and cubic at more than 3TPa. To create such novel states of matter, several kinds of isentropic-like compression techniques are being developed with high power lasers. To explore the ``Tera-Pascal Science,'' now we have a new tool which is an x-ray free electron laser as well as high power lasers. The XFEL will clear the details of the HED states and also efficiently create hot dense matter. We have started a new project on high energy density sciences using an XFEL (SACLA) in Japan, which is a HERMES (High Energy density Revolution of Matter in Extreme States) project.

  5. High alcohol consumption causes high IgE levels but not high risk of allergic disease

    DEFF Research Database (Denmark)

    Lomholt, Frederikke K; Nielsen, Sune F; Nordestgaard, Børge G

    2016-01-01

    disease. Genetically, we explored potential causal relationships between alcohol consumption and IgE levels and allergic disease. RESULTS: The multivariable adjusted odds ratio for IgE levels greater than versus less than 150 kU/L and compared with subjects without allergic disease was 2.3 (95% CI, 2......BACKGROUND: High alcohol consumption is associated with high IgE levels in observational studies; however, whether high alcohol consumption leads to high IgE levels and allergic disease is unclear. OBJECTIVE: We tested the hypothesis that high alcohol consumption is associated with high IgE levels...... and allergic disease both observationally and genetically using a Mendelian randomization design free of reverse causation and largely free of confounding. METHODS: Among 111,408 subjects aged 20 to 100 years from the general population, 50,019 had plasma IgE measurements, and 102,270 were genotyped...

  6. Isolating highly connected induced subgraphs

    DEFF Research Database (Denmark)

    Penev, Irena; Thomasse, Stephan; Trotignon, Nicolas

    2016-01-01

    the existence of a highly connected subgraph. We give several variants of our result, and for each of these variants, we give asymptotics for the bounds. We also compute optimal values for the case when k = 2. Alon, Kleitman, Saks, Seymour, and Thomassen proved that in a graph of high chromatic number...

  7. Generation of high order modes

    CSIR Research Space (South Africa)

    Ngcobo, S

    2012-07-01

    Full Text Available This work deals with the generation of symmetrical high order Laguerre Gaussian modes. These high order Laguerre-Gaussian beams are generated by forcing the laser using an annular binary Diffractive Optical Element whose geometry is in connection...

  8. High p physics at STAR

    Indian Academy of Sciences (India)

    sub sub

    physics pp. 933–944. High p. T physics at STAR. SUBHASIS CHATTOPADHYAY, for the STAR Collaboration. Variable Energy Cyclotron Centre, 1/AF Bidhan Nagar, Kolkata 700 064, India. Abstract. We discuss the capabilities of STAR in exploring the physics at high pT in ultrarelativis- tic heavy-ion colisions from RHIC at.

  9. Green accounts & day high schools

    DEFF Research Database (Denmark)

    Jørgensen, Michael Søgaard

    1997-01-01

    The arcticle presents the concept of green accounts and describes how it can be used in the daily work and the teaching at day high schools.......The arcticle presents the concept of green accounts and describes how it can be used in the daily work and the teaching at day high schools....

  10. High Pressure Research on Materials

    Indian Academy of Sciences (India)

    ing high pressure are described. Empirical equations of state. (EOS) are illustrated for some standard materials. 1. Introduction. Pressure, like temperature is an important thermodynamic param- eter in our daily life. We use pressure cookers in our kitchen to cook food and use gas cylinders containing LPG at high pressures.

  11. Fluorescence for high school students

    NARCIS (Netherlands)

    Schultheiss, N.G.; Kool, T.W.

    2012-01-01

    In a not obligatory series of lessons for high school students in the Netherlands we discuss the fluorescence aspects of anthracene. These lessons were developed because HiSPARC (High school Project on Astrophysics Research with Cosmics) detection of cosmic rays are available for different secondary

  12. High temperature electronic gain device

    International Nuclear Information System (INIS)

    McCormick, J.B.; Depp, S.W.; Hamilton, D.J.; Kerwin, W.J.

    1979-01-01

    An integrated thermionic device suitable for use in high temperature, high radiation environments is described. Cathode and control electrodes are deposited on a first substrate facing an anode on a second substrate. The substrates are sealed to a refractory wall and evacuated to form an integrated triode vacuum tube

  13. High Pressure Research on Materials

    Indian Academy of Sciences (India)

    Home; Journals; Resonance – Journal of Science Education; Volume 12; Issue 6. High Pressure Research on Materials - Production and Measurement of High Pressures in the Laboratory. P Ch Sahu N V Chandra Shekar. General Article Volume 12 Issue 6 June 2007 pp 10-23 ...

  14. 1990s: High Capacity Backbones

    Indian Academy of Sciences (India)

    First page Back Continue Last page Overview Graphics. 1990s: High Capacity Backbones. Backbone capacities increased from 2.5 Gb/s to 100s of Gb/s during the 1990's. Wavelength division multiplexing with 160 waves of 10 Gb/s was commercially available. Several high-capacity backbones built in the US and Europe.

  15. High resolution X ray spectroscopy

    International Nuclear Information System (INIS)

    Bartiromo, R.

    1987-01-01

    This paper is devoted to a detailed discussion of the physical processes which are responsible for the emission spectra of H-like and He-like ion of high Z impurities in low density plasmas. The application of high resolution X-ray spectroscopy to the diagnostic of tokamak plasmas is also discussed and examples of the results obtained are presented

  16. CROPS : high tech agricultural robots

    NARCIS (Netherlands)

    Bontsema, J.; Hemming, J.; Pekkeriet, E.J.

    2014-01-01

    In the EU-funded CROPS (Clever Robots for Crops) project high tech robots are developed for site-specific spraying and selective harvesting of fruit and fruit vegetables. The harvesting robots are being designed to harvest high-value crops such as greenhouse vegetables, fruits in orchards and grapes

  17. Managing High Blood Pressure Medications

    Science.gov (United States)

    ... Artery Disease Venous Thromboembolism Aortic Aneurysm More Managing High Blood Pressure Medications Updated:Jan 10,2018 When your doctor ... checkup. This content was last reviewed October 2016. High Blood Pressure • Home • Get the Facts About HBP • Know Your ...

  18. Controlling your high blood pressure

    Science.gov (United States)

    Controlling hypertension ... when you wake up. For people with very high blood pressure, this is when they are most at risk ... 2014 evidence-based guideline for the management of high blood pressure in adults: report from the panel members appointed ...

  19. Common High Blood Pressure Myths

    Science.gov (United States)

    ... Artery Disease Venous Thromboembolism Aortic Aneurysm More Common High Blood Pressure Myths Updated:May 4,2018 Knowing the facts ... health. This content was last reviewed October 2016. High Blood Pressure • Home • Get the Facts About HBP Introduction What ...

  20. High Blood Pressure and Women

    Science.gov (United States)

    ... Peripheral Artery Disease Venous Thromboembolism Aortic Aneurysm More High Blood Pressure and Women Updated:Jan 29,2018 Pregnancy and ... Women . This content was last reviewed October 2016. High Blood Pressure • Home • Get the Facts About HBP • Know Your ...

  1. Computing in high energy physics

    International Nuclear Information System (INIS)

    Watase, Yoshiyuki

    1991-01-01

    The increasingly important role played by computing and computers in high energy physics is displayed in the 'Computing in High Energy Physics' series of conferences, bringing together experts in different aspects of computing - physicists, computer scientists, and vendors

  2. High-Average, High-Peak Current Injector Design

    CERN Document Server

    Biedron, S G; Virgo, M

    2005-01-01

    There is increasing interest in high-average-power (>100 kW), um-range FELs. These machines require high peak current (~1 kA), modest transverse emittance, and beam energies of ~100 MeV. High average currents (~1 A) place additional constraints on the design of the injector. We present a design for an injector intended to produce the required peak currents at the injector, eliminating the need for magnetic compression within the linac. This reduces the potential for beam quality degradation due to CSR and space charge effects within magnetic chicanes.

  3. Decay modes of high-lying excitations in nuclei

    International Nuclear Information System (INIS)

    Gales, S.

    1993-01-01

    Inelastic, charge-exchange and transfer reactions induced by hadronic probes at intermediate energies have revealed a rich spectrum of new high-lying modes embedded in the nuclear continuum. The investigation of their decay properties is believed to be a severe test of their microscopic structure as predicted by nuclear models. In addition the degree of damping of these simple modes in the nuclear continuum can be obtained by means of the measured branching ratios to the various decay channels as compared to statistical model calculations. As illustrative examples the decay modes of high-spin single-particle states and isovector resonances are discussed. (author) 23 refs.; 14 figs

  4. High-energy, high-rate materials processing

    Science.gov (United States)

    Marcus, H. L.; Bourell, D. L.; Eliezer, Z.; Persad, C.; Weldon, W.

    1987-12-01

    The increasingly available range of pulsed-power, high energy kinetic storage devices, such as low-inductance pulse-forming networks, compulsators, and homopolar generators, is presently considered as a basis for industrial high energy/high rate (HEHR) processing to accomplish shock hardening, drilling, rapid surface alloying and melting, welding and cutting, transformation hardening, and cladding and surface melting in metallic materials. Time-temperature-transformation concepts furnish the basis for a fundamental understanding of the potential advantages of this direct pulsed power processing. Attention is given to the HEHR processing of a refractory molybdenum alloy, a nickel-base metallic glass, tungsten, titanium aluminides, and metal-matrix composites.

  5. A new thermocouple with high stability, high reliability and high radioresistance

    International Nuclear Information System (INIS)

    Jiang Xiangying

    1989-01-01

    A new developed NiCrSi/NiSiMg thermocouple alloys and its sheathed thermocouple have high stability, reliability and radio-resistance. Their properties are much better than conventional NiCr/NiAl (type K) thermocouple and some properties are also better than Nicrosil/Nisil (Type N) thermocouple. These new thermocouple alloys and its sheathed thermocouple can be used in scientific research field where high accuracy is need and in nuclear or non-nuclear industries requiring high reliability

  6. High Energy Density Laboratory Astrophysics

    CERN Document Server

    Lebedev, Sergey V

    2007-01-01

    During the past decade, research teams around the world have developed astrophysics-relevant research utilizing high energy-density facilities such as intense lasers and z-pinches. Every two years, at the International conference on High Energy Density Laboratory Astrophysics, scientists interested in this emerging field discuss the progress in topics covering: - Stellar evolution, stellar envelopes, opacities, radiation transport - Planetary Interiors, high-pressure EOS, dense plasma atomic physics - Supernovae, gamma-ray bursts, exploding systems, strong shocks, turbulent mixing - Supernova remnants, shock processing, radiative shocks - Astrophysical jets, high-Mach-number flows, magnetized radiative jets, magnetic reconnection - Compact object accretion disks, x-ray photoionized plasmas - Ultrastrong fields, particle acceleration, collisionless shocks. These proceedings cover many of the invited and contributed papers presented at the 6th International Conference on High Energy Density Laboratory Astrophys...

  7. High Temperature, High Frequency Fuel Metering Valve, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — Active Signal Technologies and its subcontractor Moog propose to develop a high-frequency actuator driven valve intended to achieve TRL 6 by the end of Phase II....

  8. The CMS High Granularity Calorimeter for the High Luminosity LHC

    CERN Document Server

    Sauvan, Jean-baptiste

    2017-01-01

    The High Luminosity LHC (HL-LHC) will integrate 10 times more luminosity than the LHC, posing significant challenges for radiation tolerance and event pileup on detectors, especially for forward calorimetry, and hallmarks the issue for future colliders. As part of its HL-LHC upgrade program, the CMS collaboration is designing a High Granularity Calorimeter to replace the existing endcap calorimeters. It features unprecedented transverse and longitudinal segmentation for both electromagnetic (ECAL) and hadronic (HCAL) compartments. This will facilitate particle-flow calorimetry, where the fine structure of showers can be measured and used to enhance pileup rejection and particle identification, whilst still achieving good energy resolution. The ECAL and a large fraction of HCAL will be based on hexagonal silicon sensors of 0.5 - 1 cm$^2$ cell size, with the remainder of the HCAL based on highly-segmented scintillators with silicon photomultiplier (SiPM) readout. The intrinsic high-precision timing capabilities...

  9. Biomimetic polysaccharide nanocomposites of high cellulose content and high toughness.

    Science.gov (United States)

    Svagan, Anna J; Samir, My A S Azizi; Berglund, Lars A

    2007-08-01

    Plant cell walls combine mechanical stiffness, strength and toughness despite a highly hydrated state. Inspired by this, a nanostructured cellulose network is combined with an almost viscous polysaccharide matrix in the form of a 50/50 amylopectin-glycerol blend. Homogeneous films with a microfibrillated cellulose (MFC) nanofiber content in the range of 10-70 wt % are successfully cast. Characterization is carried out by dynamic mechanical analysis, field-emission scanning electron microscopy, X-ray diffraction, and mercury density measurements. The MFC is well dispersed and predominantly oriented random-in-the-plane. High tensile strength is combined with high modulus and very high work of fracture in the nanocomposite with 70 wt % MFC. The reasons for this interesting combination of properties include nanofiber and matrix properties, favorable nanofiber-matrix interaction, good dispersion, and the ability of the MFC network to maintain its integrity to a strain of at least 8%.

  10. Very-High Efficiency, High Power Laser Diodes, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — AdTech Photonics, in collaboration with the Center for Advanced Studies in Photonics Research (CASPR) at UMBC, is pleased to submit this proposal entitled ?Very-High...

  11. Combined high vacuum/high frequency fatigue tester

    Science.gov (United States)

    Honeycutt, C. R.; Martin, T. F.

    1971-01-01

    Apparatus permits application of significantly greater number of cycles or equivalent number of cycles in shorter time than conventional fatigue test machines. Environment eliminates problems associated with high temperature oxidation and with sensitivity of refractory alloy behavior to atmospheric contamination.

  12. Production of High-Intensity, Highly Charged Ions

    CERN Document Server

    Gammino, S.

    2013-12-16

    In the past three decades, the development of nuclear physics facilities for fundamental and applied science purposes has required an increasing current of multicharged ion beams. Multiple ionization implies the formation of dense and energetic plasmas, which, in turn, requires specific plasma trapping configurations. Two types of ion source have been able to produce very high charge states in a reliable and reproducible way: electron beam ion sources (EBIS) and electron cyclotron resonance ion sources (ECRIS). Multiple ionization is also obtained in laser-generated plasmas (laser ion sources (LIS)), where the high-energy electrons and the extremely high electron density allow step-by-step ionization, but the reproducibility is poor. This chapter discusses the atomic physics background at the basis of the production of highly charged ions and describes the scientific and technological features of the most advanced ion sources. Particular attention is paid to ECRIS and the latest developments, since they now r...

  13. A high temperature high pressure cell for quasielastic neutron scattering.

    Science.gov (United States)

    Yang, F; Kaplonski, J; Unruh, T; Mamontov, E; Meyer, A

    2011-08-01

    We present our recent development of a high temperature high pressure cell for neutron scattering. Combining a water cooled Nb1Zr pressure cell body with an internal heating furnace, the sample environment can reach temperatures of up to 1500 K at a pressure of up to 200 MPa at the sample position, with an available sample volume of about 700 mm(3). The cell material Nb1Zr is specifically chosen due to its reasonable mechanical strength at elevated temperatures and fairly small neutron absorption and incoherent scattering cross sections. With this design, an acceptable signal-to-noise ratio of about 10:1 can be achieved. This opens new possibilities for quasielastic neutron scattering studies on different types of neutron spectrometers under high temperature high pressure conditions, which is particularly interesting for geological research on, e.g., water dynamics in silicate melts.

  14. ULY JUP COSPIN HIGH FLUX TELESCOPE HIGH RES. ION FLUX

    Data.gov (United States)

    National Aeronautics and Space Administration — This data set contains ion flux data recorded by the COSPIN High Flux Telescope (HFT) during the Ulysses Jupiter encounter 1992-Jan-25 to 1992-Feb-18.

  15. High Temperature, High Frequency Fuel Metering Valve Project

    Data.gov (United States)

    National Aeronautics and Space Administration — Active Signal Technologies and its subcontractor Moog propose to develop a high-frequency actuator driven valve intended to achieve TRL 6 by the end of Phase II....

  16. HIGH FREQUENCY INDUCTION WELDING OF HIGH SILICON STEEL TUBES

    Directory of Open Access Journals (Sweden)

    Ricardo Miranda Alé

    2012-06-01

    Full Text Available High-Si steel is a low cost alternative for the fabrication of tubular structures resistant to atmospheric corrosion. However, the literature has often pointed out that steels presenting a higher Si content and/or a lower Mn/Si ratio have higher susceptibility to defects at the weld bond line during HFIW (High Frequency Induction Welding process, which has been widely used for manufacturing small diameter tubes. In this study the effect of the HFIW conditions on the quality of steel tubes with high-Si content and low Mn/Si ratio is investigated. The quality of welded tubes was determined by flare test and the defects in the bond line were identified by SEM. It has been found that higher welding speeds, V-convergence angles and power input should be applied in welding of high-Si steel, when compared to similar strength C-Mn steel.

  17. High Voltage in Noble Liquids for High Energy Physics

    Energy Technology Data Exchange (ETDEWEB)

    Rebel, B. [Fermilab; Bernard, E. [Yale U.; Faham, C. H. [LBL, Berkeley; Ito, T. M. [Los Alamos; Lundberg, B. [Maryland U.; Messina, M. [Columbia U.; Monrabal, F. [Valencia U., IFIC; Pereverzev, S. P. [LLNL, Livermore; Resnati, F. [Zurich, ETH; Rowson, P. C. [SLAC; Soderberg, M. [Fermilab; Strauss, T. [Bern U.; Tomas, A. [Imperial Coll., London; Va' vra, J. [SLAC; Wang, H. [UCLA

    2014-08-22

    A workshop was held at Fermilab November 8-9, 2013 to discuss the challenges of using high voltage in noble liquids. The participants spanned the fields of neutrino, dark matter, and electric dipole moment physics. All presentations at the workshop were made in plenary sessions. This document summarizes the experiences and lessons learned from experiments in these fields at developing high voltage systems in noble liquids.

  18. High energy astrophysics and high-altitude laboratories

    International Nuclear Information System (INIS)

    Lipari, P.; University La Sapienza, Rome

    2001-01-01

    These are some summary remarks given at the Chacaltaya meeting on cosmic ray physics, held in La Paz (Bolivia), July 23-27, 2000. The meeting covered a wide range of topics in cosmic ray physics and high energy astrophysics. This contribution briefly touches on some of the highlights of the meeting, and discusses the important role that high-altitude laboratories can have in the future of these fundamental fields

  19. Design and development of high voltage high power operational ...

    Indian Academy of Sciences (India)

    and R1. A pre unity gain low pass filter also included in the designed power opamp with a cut-off frequency of 30 KHz. This is basically to filter out the high frequency noise in the input signal due to its application of driving the Piezo Actuator. The capacitive loads and high gain will cause the oscillations. The closed loop gain ...

  20. High Efficiency Power Amplifier for High Frequency Radio Transmitters

    OpenAIRE

    Vasic, Miroslav; García Suárez, Oscar; Oliver Ramírez, Jesús Angel; Alou Cervera, Pedro; Díaz López, Daniel; Cobos Márquez, José Antonio; Gimeno Martín, Alejandro; Pardo Martin, José Manuel; Benavente Peces, César; Ortega González, Francisco Javier

    2010-01-01

    Modern transmitters usually have to amplify and transmit complex communication signals with simultaneous envelope and phase modulation. Due to this property of the transmitted signal, linear power amplifiers (class A, B or AB) are usually employed as a solution for the power amplifier stage. These amplifiers have high linearity, but suffer from low efficiency when the transmitted signal has high peak-to-average power ratio. The Kahn envelope elimination and restoration (EER) technique is used...

  1. Development of a high strength high toughness ausferritic steel

    Energy Technology Data Exchange (ETDEWEB)

    Putatunda, Susil K., E-mail: sputa@eng.wayne.edu [Department of Chemical Engineering and Material Science, Wayne State University, 5050 Anthony Wayne Dr., Detroit, MI 48202 (United States); Singar, Arjun V. [Department of Chemical Engineering and Material Science, Wayne State University, 5050 Anthony Wayne Dr., Detroit, MI 48202 (United States); Tackett, Ronald; Lawes, Gavin [Department of Physics and Astronomy, Wayne State University, Detroit, MI 48201 (United States)

    2009-07-15

    A new ausferritic steel with high strength and exceptionally high fracture toughness has been developed. This steel has been synthesized integrating concepts from Austempered Ductile Cast Iron (ADI) technology. The influence of the austempering temperature on the microstructure and mechanical properties of this steel at room temperature and ambient atmosphere has been examined. The effect of microstructure on the plane strain fracture toughness and on the magnetic, electrical, and thermal properties was also investigated. Compact tension and cylindrical tensile specimens prepared from the low alloy medium carbon steel with high silicon content were initially austenitized at 927 deg. C for 2 h and then subsequently austempered at several temperatures between 260 deg. C (500 F) and 400 deg. C (750 F) to produce different microstructures. The microstructures were characterized by X-ray diffraction, scanning electron microscopy and optical metallography. A combination of exceptionally high yield strength (1336 MPa) and a high fracture of toughness of 116 MPa{radical}m (a value comparable to maraging steel) was obtained in this steel after austempering at 316 deg. C (600 F) for 2 h. Potential applications of this steel include the inexpensive fabrication of armored plates and components requiring high reliability and durability.

  2. Psoriasis and high blood pressure.

    Science.gov (United States)

    Salihbegovic, Eldina Malkic; Hadzigrahic, Nermina; Suljagic, Edin; Kurtalic, Nermina; Sadic, Sena; Zejcirovic, Alema; Mujacic, Almina

    2015-02-01

    Psoriasis is a chronic skin ailment which can be connected with an increased occurrence of other illnesses, including high blood pressure. A prospective study has been conducted which included 70 patients affected by psoriasis, both genders, older than 18 years. Average age being 47,14 (SD= ±15,41) years, from that there were 36 men or 51,43 and 34 women or 48,57%. Average duration of psoriasis was 15,52 (SD=±12,54) years. Frequency of high blood pressure in those affected by psoriasis was 54,28%. Average age of the patients with psoriasis and high blood pressure was 53,79 year (SD=±14,15) and average duration of psoriasis was 17,19 years (SD=±13,51). Average values of PASI score were 16,65. Increase in values of PASI score and high blood pressure were statistically highly related (r=0,36, p=0,0001). Psoriasis was related to high blood pressure and there was a correlation between the severity of psoriasis and high blood pressure.

  3. Survey of Processing Methods for High Strength High Conductivity Wires for High Field Magnet Applications

    International Nuclear Information System (INIS)

    Han, K.; Embury, J.D.

    1998-01-01

    This paper will deal with the basic concepts of attaining combination of high strength and high conductivity in pure materials, in-situ composites and macrocomposites. It will survey current attainments, and outline where some future developments may lie in developing wire products that are close to the theoretical strength of future magnet applications

  4. Final report: High current capacity high temperature superconducting film based tape for high field magnets

    International Nuclear Information System (INIS)

    Ying Xin

    2000-01-01

    The primary goal of the program was to establish the process parameters for the continuous deposition of high quality, superconducting YBCO films on one meter lengths of buffered RABiTS tape using MOCVD and to characterize the potential utility of the resulting tapes in high field magnet applications

  5. Survey of Processing Methods for High Strength High Conductivity Wires for High Field Magnet Applications

    Energy Technology Data Exchange (ETDEWEB)

    Han, K.; Embury, J.D.

    1998-10-01

    This paper will deal with the basic concepts of attaining combination of high strength and high conductivity in pure materials, in-situ composites and macrocomposites. It will survey current attainments, and outline where some future developments may lie in developing wire products that are close to the theoretical strength of future magnet applications.

  6. Conference on High Energy Physics

    CERN Document Server

    2016-01-01

    Conference on High Energy Physics (HEP 2016) will be held from August 24 to 26, 2016 in Xi'an, China. This Conference will cover issues on High Energy Physics. It dedicates to creating a stage for exchanging the latest research results and sharing the advanced research methods. HEP 2016 will be an important platform for inspiring international and interdisciplinary exchange at the forefront of High Energy Physics. The Conference will bring together researchers, engineers, technicians and academicians from all over the world, and we cordially invite you to take this opportunity to join us for academic exchange and visit the ancient city of Xi’an.

  7. High-beta linac structures

    International Nuclear Information System (INIS)

    Schriber, S.O.

    1979-01-01

    Accelerating structures for high-beta linacs that have been and are in use are reviewed in terms of their performance. Particular emphasis is given to room-temperature structures and the disk-and-washer structure. The disk-and-washer structure has many attractive features that are discussed for pulsed high-gradient linacs, for 100% duty-cycle medium-gradient linacs and for high-current linacs requiring maximal amounts of stored energy in the electric fields available to the beam

  8. Ultrafast, high precision gated integrator

    Energy Technology Data Exchange (ETDEWEB)

    Wang, X.

    1995-01-01

    An ultrafast, high precision gated integrator has been developed by introducing new design approaches that overcome the problems associated with earlier gated integrator circuits. The very high speed is evidenced by the output settling time of less than 50 ns and 20 MHz input pulse rate. The very high precision is demonstrated by the total output offset error of less than 0.2mV and the output droop rate of less than 10{mu}V/{mu}s. This paper describes the theory of this new gated integrator circuit operation. The completed circuit test results are presented.

  9. High-speed photonics interconnects

    CERN Document Server

    Chrostowski, Lukas

    2013-01-01

    Dramatic increases in processing power have rapidly scaled on-chip aggregate bandwidths into the Tb/s range. This necessitates a corresponding increase in the amount of data communicated between chips, so as not to limit overall system performance. To meet the increasing demand for interchip communication bandwidth, researchers are investigating the use of high-speed optical interconnect architectures. Unlike their electrical counterparts, optical interconnects offer high bandwidth and negligible frequency-dependent loss, making possible per-channel data rates of more than 10 Gb/s. High-Speed

  10. Legal highs on the Internet.

    Science.gov (United States)

    Hillebrand, Jennifer; Olszewski, Deborah; Sedefov, Roumen

    2010-02-01

    This article describes the findings of a descriptive analysis of 27 online drug retailers selling legal alternatives to illegal drugs, commonly referred to as "herbal highs" and "legal highs" in 2008 . The study attempted to quantify the online availability of drug retailers, to describe common products and characteristics in EU-based retail sales. The findings highlight the concern about the lack of objective information about products offered, including potential risks to health. Systems should be developed to assess the contents of products and the accuracy of information provided on the Internet, alongside continued monitoring of this market for "legal high" substances.

  11. High gain high efficiency resonant DC-DC converter

    Science.gov (United States)

    Shang, Fei

    Low voltage power sources have played an important role in applications such as automotive system, renewable energy power generation and so on, where require a high gain DC-DC step-up converter. The converter is going to sustain a very high input current which can bring many design challenges in the existing topologies, such as high component current stress and power loss, complex and costly design for magnetic components, high input current ripple, etc. A new topology of high gain DCDC step-up converter proposed in this dissertation. The topology has many merits such as high gain capability, high efficiency, low components stress and requirement of the transformer, simple topology with less number of active switching devices, and easy to control. The dissertation carries out theoretical analysis of the proposed topology under different operating modes and the voltage gain has been deduced for each mode. The design of circuit components has been well studied, including the power devices current stress and power, the selection of transformer turns-ratio, the design method of the resonant tank and input current ripple. System dynamic state-space models are acquired by using generalized averaging method. Small signal model of the converter is achieved by linearization of the dynamic model around the operating points. The stability study indicates that the open loop system is stable at all operating points, except some operating points containing RHP zeros which can cause closed loop system unstable. The parameter sensitivity study shows that the system transfer function is not greatly affected by the variation of the leakage inductance and load resistance. A design of PI controller is implemented to achieve the output voltage regulation. Simulations have been carried out to validate the circuit operation and support the design analysis. A 2kW prototype has been built for experimental testing. The experimental results are in a good agreement with the theoretical

  12. High School Library Data Processing

    Directory of Open Access Journals (Sweden)

    Betty Flora

    1969-03-01

    Full Text Available Planning and operation of an automated high school library system is described which utilizes an IBM 1401 data processing system installed for teaching purposes. Book orfering, shelf listing and circulation have been computerized.

  13. Diagnosis of High Blood Pressure

    Medline Plus

    Full Text Available ... system activity , and blood vessel structure and function. Biology and High Blood Pressure Researchers continue to study ... and Your Heart U.S. Department of Health and Human Services' 2008 Physical Activity Guidelines for Americans Maintaining ...

  14. Problems of high energy physics

    International Nuclear Information System (INIS)

    Kadyshevskij, V.G.

    1989-01-01

    Some problems of high energy physics are discussed. The main attention is paid to describibg the standard model. The model comprises quantum chromodynamics and electroweak interaction theory. The problem of CP breaking is considered as well. 8 refs.; 1 tab

  15. High Temperature Materials Laboratory (HTML)

    Data.gov (United States)

    Federal Laboratory Consortium — The six user centers in the High Temperature Materials Laboratory (HTML), a DOE User Facility, are dedicated to solving materials problems that limit the efficiency...

  16. High Pressure Industrial Water Facility

    Science.gov (United States)

    1992-01-01

    In conjunction with Space Shuttle Main Engine testing at Stennis, the Nordberg Water Pumps at the High Pressure Industrial Water Facility provide water for cooling the flame deflectors at the test stands during test firings.

  17. SEDflume - High Shear Stress Flume

    Data.gov (United States)

    Federal Laboratory Consortium — The U.S. Army Corps of Engineers High Shear Stress flume (SEDflume) is designed for estimating erosion rates of fine-grained and mixed fine/coarse grained sediments...

  18. High-level-waste immobilization

    International Nuclear Information System (INIS)

    Crandall, J.L.

    1982-01-01

    Analysis of risks, environmental effects, process feasibility, and costs for disposal of immobilized high-level wastes in geologic repositories indicates that the disposal system safety has a low sensitivity to the choice of the waste disposal form

  19. Designing High-Trust Organizations

    DEFF Research Database (Denmark)

    Jagd, Søren

    The specific problem considered in this paper is what are the key issues to consider for managers involved in designing high-trust organizations, a design problem still not properly explored. This paper intends to take the first step in filling this lacuna. In the paper, I first present the exist......The specific problem considered in this paper is what are the key issues to consider for managers involved in designing high-trust organizations, a design problem still not properly explored. This paper intends to take the first step in filling this lacuna. In the paper, I first present...... the existing management and research literature on building high-trust organizations. Then I explore Alan Fox’s (1974) analysis of low-trust vs. high-trust dynamics which, I argue, may serve as a theoretically stronger basis for understanding the issues management have to consider when designing hightrust...... organizations...

  20. Engineering high quality medical software

    CERN Document Server

    Coronato, Antonio

    2018-01-01

    This book focuses on high-confidence medical software in the growing field of e-health, telecare services and health technology. It covers the development of methodologies and engineering tasks together with standards and regulations for medical software.

  1. Sleep in High Stress Occupations

    Science.gov (United States)

    Flynn-Evans, Erin

    2014-01-01

    High stress occupations are associated with sleep restriction, circadian misalignment and demanding workload. This presentation will provide an overview of sleep duration, circadian misalignment and fatigue countermeasures and performance outcomes during spaceflight and commercial aviation.

  2. Applications of high power microwaves

    International Nuclear Information System (INIS)

    Benford, J.; Swegle, J.

    1993-01-01

    The authors address a number of applications for HPM technology. There is a strong symbiotic relationship between a developing technology and its emerging applications. New technologies can generate new applications. Conversely, applications can demand development of new technological capability. High-power microwave generating systems come with size and weight penalties and problems associated with the x-radiation and collection of the electron beam. Acceptance of these difficulties requires the identification of a set of applications for which high-power operation is either demanded or results in significant improvements in peRFormance. The authors identify the following applications, and discuss their requirements and operational issues: (1) High-energy RF acceleration; (2) Atmospheric modification (both to produce artificial ionospheric mirrors for radio waves and to save the ozone layer); (3) Radar; (4) Electronic warfare; and (5) Laser pumping. In addition, they discuss several applications requiring high average power than border on HPM, power beaming and plasma heating

  3. High Blood Pressure in Pregnancy

    Science.gov (United States)

    ... of the baby. Controlling your blood pressure during pregnancy and getting regular prenatal care are important for ... your baby. Treatments for high blood pressure in pregnancy may include close monitoring of the baby, lifestyle ...

  4. High temperature superconductor accelerator magnets

    NARCIS (Netherlands)

    van Nugteren, J.

    2016-01-01

    For future particle accelerators bending dipoles are considered with magnetic fields exceeding 20T. This can only be achieved using high temperature superconductors (HTS). These exhibit different properties from classical low temperature superconductors and still require significant research and

  5. Diagnosis of High Blood Pressure

    Medline Plus

    Full Text Available ... physical activity Drinking too much alcohol Stress Family History A family history of high blood pressure raises the risk of ... Genetic causes of this condition are why family history is a risk factor for this condition. Screening ...

  6. Future demands highly integrated solutions

    Energy Technology Data Exchange (ETDEWEB)

    Mangler, Andreas [Rutronik Elektronische Bauelemente GmbH, Ispringen (Germany). Strategic Marketing

    2010-07-01

    The future energy supply with a high number of decentral power plants depends on the use of innovative system technology. It is a precondition for a well-functioning grid and power management over all voltage levels. (orig.)

  7. Research in high energy physics

    International Nuclear Information System (INIS)

    1992-01-01

    This report discusses research being conducted in high energy physics in the following areas; quantum chromodynamics; drift chambers; proton-antiproton interactions; particle decays; particle production; polarimeters; quark-gluon plasma; and conformed field theory

  8. Modular High Voltage Power Supply

    Energy Technology Data Exchange (ETDEWEB)

    Newell, Matthew R. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2017-05-18

    The goal of this project is to develop a modular high voltage power supply that will meet the needs of safeguards applications and provide a modular plug and play supply for use with standard electronic racks.

  9. Research in high energy physics

    International Nuclear Information System (INIS)

    1992-01-01

    This report discusses research being conducted in high energy physics in the following areas: quantum chromodynamics; drift chambers; proton-antiproton interactions; particle decays; particle production; polarimeters; quark-gluon plasma; and conformed field theory

  10. Computing in high energy physics

    International Nuclear Information System (INIS)

    Smith, Sarah; Devenish, Robin

    1989-01-01

    Computing in high energy physics has changed over the years from being something one did on a slide-rule, through early computers, then a necessary evil to the position today where computers permeate all aspects of the subject from control of the apparatus to theoretical lattice gauge calculations. The state of the art, as well as new trends and hopes, were reflected in this year's 'Computing In High Energy Physics' conference held in the dreamy setting of Oxford's spires. The conference aimed to give a comprehensive overview, entailing a heavy schedule of 35 plenary talks plus 48 contributed papers in two afternoons of parallel sessions. In addition to high energy physics computing, a number of papers were given by experts in computing science, in line with the conference's aim – 'to bring together high energy physicists and computer scientists'

  11. [Research in high energy physics

    International Nuclear Information System (INIS)

    1991-01-01

    This report discusses progress in the following research in high energy physics: The crystal ball experiment; delco at PEP; proton decay experiment; MACRO detector; mark III detector; SLD detector; CLEO II detector; and the caltech L3 group

  12. Diagnosis of High Blood Pressure

    Medline Plus

    Full Text Available ... management techniques include: Being physically active Listening to music or focusing on something calm or peaceful Performing ... multidisciplinary researchers on June 10, 2016, to share current scientific k... View all events on High Blood ...

  13. High temperature structural insulating material

    Science.gov (United States)

    Chen, W.Y.

    1984-07-27

    A high temperature structural insulating material useful as a liner for cylinders of high temperature engines through the favorable combination of high service temperature (above about 800/sup 0/C), low thermal conductivity (below about 0.2 W/m/sup 0/C), and high compressive strength (above about 250 psi). The insulating material is produced by selecting hollow ceramic beads with a softening temperature above about 800/sup 0/C, a diameter within the range of 20-200 ..mu..m, and a wall thickness in the range of about 2 to 4 ..mu..m; compacting the beads and a compatible silicate binder composition under pressure and sintering conditions to provide the desired structural form with the structure having a closed-cell, compact array of bonded beads.

  14. Medications for High Blood Pressure

    Science.gov (United States)

    ... Consumers Home For Consumers Consumer Updates Medications for High Blood Pressure Share Tweet Linkedin Pin it More sharing options Linkedin Pin it Email Print Hypertension tends to worsen with age and you cannot ...

  15. High blood pressure and diet

    Science.gov (United States)

    Hypertension - diet ... diet is a proven way to help control high blood pressure . These changes can also help you lose weight ... DIET The low-salt Dietary Approaches to Stop Hypertension (DASH) diet is proven to help lower blood ...

  16. Geographies of High Frequency Trading

    DEFF Research Database (Denmark)

    Grindsted, Thomas Skou

    2016-01-01

    This paper investigates the geographies of high frequency trading. Today shares shift hands within micro seconds, giving rise to a form of financial geographies termed algorithmic capitalism. This notion refers to the different spatio-temporalities produced by high frequency trading, under...... the valuation of time. As high frequency trading accelerates financial markets, the paper examines the spatio-temporalities of automated trading by the ways in which the speed of knowledge exploitation in financial markets is not only of interest, but also the expansion between different temporalities....... The paper demonstrates how the intensification of time-space compression produces radical new dynamics in the financial market and develops information rent in HFT as convertible to a time rent and a spatio-temporal rent. The final section discusses whether high frequency trading only responds to crises...

  17. High-End Scientific Computing

    Science.gov (United States)

    EPA uses high-end scientific computing, geospatial services and remote sensing/imagery analysis to support EPA's mission. The Center for Environmental Computing (CEC) assists the Agency's program offices and regions to meet staff needs in these areas.

  18. High Power Orbit Transfer Vehicle

    National Research Council Canada - National Science Library

    Gulczinski, Frank

    2003-01-01

    ... from Virginia Tech University and Aerophysics, Inc. to examine propulsion requirements for a high-power orbit transfer vehicle using thin-film voltaic solar array technologies under development by the Space Vehicles Directorate (dubbed PowerSail...

  19. MongoDB high availability

    CERN Document Server

    Mehrabani, Afshin

    2014-01-01

    This book has a perfect balance of concepts and their practical implementation along with solutions to make a highly available MongoDB server with clear instructions and guidance. If you are using MongoDB in a production environment and need a solution to make a highly available MongoDB server, this book is ideal for you. Familiarity with MongoDB is expected so that you understand the content of this book.

  20. Aspects of high temperature superconductivity

    International Nuclear Information System (INIS)

    Deutscher, G.

    1989-01-01

    We present some remarks on special features that distinguish the phenomenology of the new high T c oxides from that of the conventional superconductors. They include a measurable width of the critical region and a high sensitivity to crystallographic defects. A consistent Landau Ginsburg interpretation is possible, with a short coherence length <15 A and a penetration depth <900 A. The latter is somewhat smaller than the currently accepted value, and implies a broad band scheme

  1. RavenDB high performance

    CERN Document Server

    Ritchie, Brian

    2013-01-01

    RavenDB High Performance is comprehensive yet concise tutorial that developers can use to.This book is for developers & software architects who are designing systems in order to achieve high performance right from the start. A basic understanding of RavenDB is recommended, but not required. While the book focuses on advanced topics, it does not assume that the reader has a great deal of prior knowledge of working with RavenDB.

  2. High Speed Smoke Flow Visualization.

    Science.gov (United States)

    1981-03-01

    releasable to the National Technical Information Service (NTIS). At NTIS, it will be available to the general public, including foreign nations. This... information . 9 The initial work focused on the evaluation of the flow field within the high speed flow visualization tunnels and the optical and...with the high speed flow visuLl iza tion; it waIs used to take simul taneous smoke/Schlieren photographs. Siice it allowed for this unique method of

  3. Moire interferometry at high temperatures

    Science.gov (United States)

    Wu, Jau-Je

    1992-01-01

    The objective of this study was to provide an optical technique allowing full-field in-plane deformation measurements at high temperature by using high-sensitivity moire interferometry. This was achieved by a new approach of performing deformation measurements at high temperatures in a vacuum oven using an achromatic interferometer. The moire system setup was designed with particular consideration for the stability, compactness, flexibility, and ease of control. A vacuum testing environment was provided to minimize the instability of the patterns by protecting the optical instruments from the thermal convection currents. Also, a preparation procedure for the high-temperature specimen grating was developed with the use of the plasma-etched technique. Gold was used as a metallic layer in this procedure. This method was demonstrated on a ceramic block, metal/matrix composite, and quartz. Thermal deformation of a quartz specimen was successfully measured in vacuum at 980 degrees Celsius, with the sensitivity of 417 nm per fringe. The stable and well-defined interference patterns confirmed the feasibility of the developments, including the high-temperature moire system and high-temperature specimen grating. The moire system was demonstrated to be vibration-insensitive. Also, the contrast of interference fringes at high temperature was enhanced by means of a spatial filter and a narrow band interference filter to minimize the background noise from the flow of the specimen and heater. The system was verified by a free thermal expansion test of an aluminum block. Good agreement demonstrated the validity of the optical design. The measurements of thermal deformation mismatch were performed on a graphite/epoxy composite, a metal/matrix composite equipped with an optical fiber, and a cutting tool bit. A high-resolution data-reduction technique was used to measure the strain distribution of the cutting tool bit.

  4. HIMARS: A High Performance PBL

    Science.gov (United States)

    2014-08-01

    School hiMARS: A high PeRfoRMAnce Pbl By: Jacques S. Gansler and William Lucyshyn 18 56 U N IV ERSITY O F M A R Y L A N D UMD-LM-14-182 Report...REPORT TYPE 3. DATES COVERED 00-00-2014 to 00-00-2014 4. TITLE AND SUBTITLE HIMARS: A High Performance PBL 5a. CONTRACT NUMBER 5b. GRANT...11 The PBL Model ............................................................................................................. 12

  5. Handbook of High Resolution Spectroscopy

    OpenAIRE

    2011-01-01

    The field of High resolution Spectroscopy has been considerably extended and even redefined in some areas. Combining the knowledge of spectroscopy laser technology chemical computation and experiments Handbook of High resolution Spectroscopy provides a comprehensive survey of the whole field as it presents itself today with emphasis on the recent developments. This essential handbook for advanced research students graduate students and researchers takes a systematic approach through the rang...

  6. High to ultra-high power electrical energy storage.

    Science.gov (United States)

    Sherrill, Stefanie A; Banerjee, Parag; Rubloff, Gary W; Lee, Sang Bok

    2011-12-14

    High power electrical energy storage systems are becoming critical devices for advanced energy storage technology. This is true in part due to their high rate capabilities and moderate energy densities which allow them to capture power efficiently from evanescent, renewable energy sources. High power systems include both electrochemical capacitors and electrostatic capacitors. These devices have fast charging and discharging rates, supplying energy within seconds or less. Recent research has focused on increasing power and energy density of the devices using advanced materials and novel architectural design. An increase in understanding of structure-property relationships in nanomaterials and interfaces and the ability to control nanostructures precisely has led to an immense improvement in the performance characteristics of these devices. In this review, we discuss the recent advances for both electrochemical and electrostatic capacitors as high power electrical energy storage systems, and propose directions and challenges for the future. We asses the opportunities in nanostructure-based high power electrical energy storage devices and include electrochemical and electrostatic capacitors for their potential to open the door to a new regime of power energy.

  7. High Power High Efficiency Diode Laser Stack for Processing

    Science.gov (United States)

    Gu, Yuanyuan; Lu, Hui; Fu, Yueming; Cui, Yan

    2018-03-01

    High-power diode lasers based on GaAs semiconductor bars are well established as reliable and highly efficient laser sources. As diode laser is simple in structure, small size, longer life expectancy with the advantages of low prices, it is widely used in the industry processing, such as heat treating, welding, hardening, cladding and so on. Respectively, diode laser could make it possible to establish the practical application because of rectangular beam patterns which are suitable to make fine bead with less power. At this power level, it can have many important applications, such as surgery, welding of polymers, soldering, coatings and surface treatment of metals. But there are some applications, which require much higher power and brightness, e.g. hardening, key hole welding, cutting and metal welding. In addition, High power diode lasers in the military field also have important applications. So all developed countries have attached great importance to high-power diode laser system and its applications. This is mainly due their low performance. In this paper we will introduce the structure and the principle of the high power diode stack.

  8. High efficiency targets for high gain inertial confinement fusion

    International Nuclear Information System (INIS)

    Gardner, J.H.; Bodner, S.E.

    1986-01-01

    Rocket efficiencies as high as 15% are possible using short wavelength lasers and moderately high aspect ratio pellet designs. These designs are made possible by two recent breakthroughs in physics constraints. First is the development of the Induced Spatial Incoherence (ISI) technique which allows uniform illumination of the pellet and relaxes the constraint of thermal smoothing, permitting the use of short wavelength laser light. Second is the discovery that the Rayleigh-Taylor growth rate is considerably reduced at the short laser wavelengths. By taking advantage of the reduced constraints imposed by nonuniform laser illumination and Rayleigh-Taylor instability, pellets using 1/4 micron laser light and initial aspect ratios of about 10 (with in flight aspect ratios of about 150 to 200) may produce energy gains as high as 200 to 250

  9. Discovering highly informative feature set over high dimensions

    KAUST Repository

    Zhang, Chongsheng

    2012-11-01

    For many textual collections, the number of features is often overly large. These features can be very redundant, it is therefore desirable to have a small, succinct, yet highly informative collection of features that describes the key characteristics of a dataset. Information theory is one such tool for us to obtain this feature collection. With this paper, we mainly contribute to the improvement of efficiency for the process of selecting the most informative feature set over high-dimensional unlabeled data. We propose a heuristic theory for informative feature set selection from high dimensional data. Moreover, we design data structures that enable us to compute the entropies of the candidate feature sets efficiently. We also develop a simple pruning strategy that eliminates the hopeless candidates at each forward selection step. We test our method through experiments on real-world data sets, showing that our proposal is very efficient. © 2012 IEEE.

  10. High surface area electrode for high efficient microbial electrosynthesis

    Science.gov (United States)

    Nie, Huarong; Cui, Mengmeng; Lu, Haiyun; Zhang, Tian; Russell, Thomas; Lovley, Derek

    2012-02-01

    Microbial electrosynthesis, a process in which microorganisms directly accept electrons from an electrode to convert carbon dioxide and water into multi carbon organic compounds, affords a novel route for the generation of valuable products from electricity or even wastewater. The surface area of the electrode is critical for high production. A biocompatible, highly conductive, three-dimensional cathode was fabricated from a carbon nanotube textile composite to support the microorganism to produce acetate from carbon dioxide. The high surface area and macroscale porous structure of the intertwined CNT coated textile ?bers provides easy microbe access. The production of acetate using this cathode is 5 fold larger than that using a planar graphite electrode with the same volume. Nickel-nanowire-modified carbon electrodes, fabricated by microwave welding, increased the surface area greatly, were able to absorb more bacteria and showed a 1.5 fold increase in performance

  11. High point for CERN and high-temperature superconductors

    CERN Multimedia

    2007-01-01

    Amalia Ballarino is named the Superconductor Industry Person of the year 2006. Amalia Ballarino showing a tape of high-superconducting material used for the LHC current leads.The CERN project leader for the high-temperature superconducting current leads for the LHC, Amalia Ballarino, has received the award for "Superconductor Industry Person of the Year". This award, the most prestigious international award in the development and commercialization of superconductors, is presented by the leading industry newsletter "Superconductor Week". Amalia Ballarino was selected from dozens of nominations from around the world by a panel of recognized leading experts in superconductivity. "It is a great honour for me," says Amalia Ballarino. "It has been many years of hard work, and it’s a great satisfaction to see that the work has been completed successfully." Amalia Ballarino has been working on high-temperature superconducting materials sin...

  12. Note: High precision measurements using high frequency gigahertz signals

    Science.gov (United States)

    Jin, Aohan; Fu, Siyuan; Sakurai, Atsunori; Liu, Liang; Edman, Fredrik; Pullerits, Tõnu; Öwall, Viktor; Karki, Khadga Jung

    2014-12-01

    Generalized lock-in amplifiers use digital cavities with Q-factors as high as 5 × 108 to measure signals with very high precision. In this Note, we show that generalized lock-in amplifiers can be used to analyze microwave (giga-hertz) signals with a precision of few tens of hertz. We propose that the physical changes in the medium of propagation can be measured precisely by the ultra-high precision measurement of the signal. We provide evidence to our proposition by verifying the Newton's law of cooling by measuring the effect of change in temperature on the phase and amplitude of the signals propagating through two calibrated cables. The technique could be used to precisely measure different physical properties of the propagation medium, for example, the change in length, resistance, etc. Real time implementation of the technique can open up new methodologies of in situ virtual metrology in material design.

  13. High Molecular Weight Polybenzimidazole Membranes for High Temperature PEMFC

    DEFF Research Database (Denmark)

    Yang, Jingshuai; Cleemann, Lars Nilausen; Steenberg, T.

    2014-01-01

    tensile strength of 30.3 MPa at room temperature or 7.3 MPa at 130 °C and a proton conductivity of 0.14 S cm–1 at 160 °C. Fuel cell tests with H2 and air at 160 °C showed high open circuit voltage, power density and a low degradation rate of 1.5 μV h–1 at a constant load of 300 mA cm–2.......High temperature operation of proton exchange membrane fuel cells under ambient pressure has been achieved by using phosphoric acid doped polybenzimidazole (PBI) membranes. To optimize the membrane and fuel cells, high performance polymers were synthesized of molecular weights from 30 to 94 k...

  14. Microstructural evolution in high strength materials at high strain rates

    Science.gov (United States)

    Bassim, M. N.; Bolduc, M.; Odeshi, A. G.; Mirfarkraei, S.

    2006-08-01

    High strength materials such as used as armor plate have been investigated in torsion using Split Hopkinson Bars for the purpose of obtaining stress-strain curves and for examining the mechanism of plastic deformation in terms of mechanical instability due to thermal softening at high strain rates. A comparative study of the plastic deformation behavior of RHA steel, Aluminum 5083 H131 alloy and Tungsten A90S alloy under the loading condition at high strain rates is carried out and the effect of strain rate on shear flow stress and stress-strain profiles is presented. Strain rate sensitivities of the materials are evaluated and discussed with respect to mechanical instability and adiabatic shear strain localization.

  15. High Efficiency Power Converter for Low Voltage High Power Applications

    DEFF Research Database (Denmark)

    Nymand, Morten

    The topic of this thesis is the design of high efficiency power electronic dc-to-dc converters for high-power, low-input-voltage to high-output-voltage applications. These converters are increasingly required for emerging sustainable energy systems such as fuel cell, battery or photo voltaic based...... energy systems. Applications include systems for emergency power back-up (UPS), de-centralized combined heat and power systems, traction applications such as hybrid electrical vehicles, forklift trucks and special applications such as low emission power generation for truck and ship containers...... be applied to all isolated boost type converters and, in principle, an unlimited number of power stages can be paralleled. Feasibility and operation of the new topology are demonstrated on a dual 3 kW and a quad 10 kW prototype converter. Measured peak efficiency is 98.2% and worst case minimum efficiency...

  16. High bandgap III-V alloys for high efficiency optoelectronics

    Energy Technology Data Exchange (ETDEWEB)

    Alberi, Kirstin; Mascarenhas, Angelo; Wanlass, Mark

    2017-01-10

    High bandgap alloys for high efficiency optoelectronics are disclosed. An exemplary optoelectronic device may include a substrate, at least one Al.sub.1-xIn.sub.xP layer, and a step-grade buffer between the substrate and at least one Al.sub.1-xIn.sub.xP layer. The buffer may begin with a layer that is substantially lattice matched to GaAs, and may then incrementally increase the lattice constant in each sequential layer until a predetermined lattice constant of Al.sub.1-xIn.sub.xP is reached.

  17. Decay properties of high-lying single-particles modes

    Science.gov (United States)

    Beaumel, D.; Fortier, S.; Galès, S.; Guillot, J.; Langevin-Joliot, H.; Laurent, H.; Maison, J. M.; Vernotte, J.; Bordewijck, J.; Brandenburg, S.; Krasznahorkay, A.; Crawley, G. M.; Massolo, C. P.; Renteria, M.; Khendriche, A.

    1996-02-01

    The neutron decay of high-lying single-particle states in 64Ni, 90Zr, 120Sn and 208Pb excited by means of the (α, 3He) reaction has been investigated at 120 MeV incident energy using the multidetector EDEN. The characteristics of this reaction are studied using inclusive spectra and angular correlation analysis. The structure located between 11 and 15 MeV in 91Zr, and between 8 and 12 MeV excitation energy in 209Pb display large departures from a pure statistical decay. The corresponding non-statistical branching ratios are compared with the results of two theoretical calculations.

  18. High-lying doubly excited states of H-

    International Nuclear Information System (INIS)

    Ho, Y.K.

    1990-01-01

    We report a calculation for 1 S e resonance parameters in electron-hydrogen scattering converging on the N = 4 to N = 9 hydrogen thresholds. Resonance energy positions and widths are calculated by using a method of complex coordinate rotations, with quantum numbers K, T, N and n given to each resonant state. Results are compared with the recent R-matrix calculations for resonances below the N = 4 and N = 5 hydrogen thresholds, and with the hyperspherical coordinate calculations for resonances associated with the N = 6 - 9 hydrogen thresholds. The present results are also used to interpret the grandparent model for high-lying doubly excited two-electron atomic systems. (author)

  19. High-pressure-high-temperature treatment of natural diamonds

    CERN Document Server

    Royen, J V

    2002-01-01

    The results are reported of high-pressure-high-temperature (HPHT) treatment experiments on natural diamonds of different origins and with different impurity contents. The diamonds are annealed in a temperature range up to 2000 sup o C at stabilizing pressures up to 7 GPa. The evolution is studied of different defects in the diamond crystal lattice. The influence of substitutional nitrogen atoms, plastic deformation and the combination of these is discussed. Diamonds are characterized at room and liquid nitrogen temperature using UV-visible spectrophotometry, Fourier transform infrared spectrophotometry and photoluminescence spectrometry. The economic implications of diamond HPHT treatments are discussed.

  20. High efficiency transformation of E. coli by high voltage electroporation.

    OpenAIRE

    Dower, W J; Miller, J F; Ragsdale, C W

    1988-01-01

    E. coli can be transformed to extremely high efficiencies by subjecting a mixture of cells and DNA to brief but intense electrical fields of exponential decay waveform (electroporation). We have obtained 10(9) to 10(10) transformants/micrograms with strains LE392 and DH5 alpha, and plasmids pUC18 and pBR329. The process is highly dependent on two characteristics of the electrical pulse: the electric field strength and the pulse length (RC time constant). The frequency of transformation is a l...