  1. High resolution x-ray microtomography of biological samples: Requirements and strategies for satisfying them

    Energy Technology Data Exchange (ETDEWEB)

    Loo, B.W. Jr. [Univ. of California, San Francisco, CA (United States)]|[Univ. of California, Davis, CA (United States)]|[Lawrence Berkeley National Lab., CA (United States); Rothman, S.S. [Univ. of California, San Francisco, CA (United States)]|[Lawrence Berkeley National Lab., CA (United States)

    1997-02-01

    High resolution x-ray microscopy has been made possible in recent years primarily by two new technologies: microfabricated diffractive lenses for soft x-rays with about 30-50 nm resolution, and high brightness synchrotron x-ray sources. X-ray microscopy occupies a special niche in the array of biological microscopic imaging methods. It extends the capabilities of existing techniques mainly in two areas: a previously unachievable combination of sub-visible resolution and multi-micrometer sample size, and new contrast mechanisms. Because of the soft x-ray wavelengths used in biological imaging (about 1-4 nm), XM is intermediate in resolution between visible light and electron microscopies. Similarly, the penetration depth of soft x-rays in biological materials is such that the ideal sample thickness for XM falls in the range of 0.25 - 10 {mu}m, between that of VLM and EM. XM is therefore valuable for imaging of intermediate level ultrastructure, requiring sub-visible resolutions, in intact cells and subcellular organelles, without artifacts produced by thin sectioning. Many of the contrast producing and sample preparation techniques developed for VLM and EM also work well with XM. These include, for example, molecule specific staining by antibodies with heavy metal or fluorescent labels attached, and sectioning of both frozen and plastic embedded tissue. However, there is also a contrast mechanism unique to XM that exists naturally because a number of elemental absorption edges lie in the wavelength range used. In particular, between the oxygen and carbon absorption edges (2.3 and 4.4 nm wavelength), organic molecules absorb photons much more strongly than does water, permitting element-specific imaging of cellular structure in aqueous media, with no artifically introduced contrast agents. For three-dimensional imaging applications requiring the capabilities of XM, an obvious extension of the technique would therefore be computerized x-ray microtomography (XMT).

  2. Biological sample collector

    Science.gov (United States)

    Murphy, Gloria A.

    2010-09-07

    A biological sample collector is adapted to a collect several biological samples in a plurality of filter wells. A biological sample collector may comprise a manifold plate for mounting a filter plate thereon, the filter plate having a plurality of filter wells therein; a hollow slider for engaging and positioning a tube that slides therethrough; and a slide case within which the hollow slider travels to allow the tube to be aligned with a selected filter well of the plurality of filter wells, wherein when the tube is aligned with the selected filter well, the tube is pushed through the hollow slider and into the selected filter well to sealingly engage the selected filter well and to allow the tube to deposit a biological sample onto a filter in the bottom of the selected filter well. The biological sample collector may be portable.

  3. Enhanced Biological Sampling Data

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — This is a database of a variety of biological, reproductive, and energetic data collected from fish on the continental shelf in the northwest Atlantic Ocean....

  4. Biological Sample Monitoring Database (BSMDBS)

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — The Biological Sample Monitoring Database System (BSMDBS) was developed for the Northeast Fisheries Regional Office and Science Center (NER/NEFSC) to record and...

  5. Prediction uncertainty assessment of a systems biology model requires a sample of the full probability distribution of its parameters

    OpenAIRE

    Simon van Mourik; Cajo ter Braak; Hans Stigter; Jaap Molenaar

    2014-01-01

    Multi-parameter models in systems biology are typically ‘sloppy’: some parameters or combinations of parameters may be hard to estimate from data, whereas others are not. One might expect that parameter uncertainty automatically leads to uncertain predictions, but this is not the case. We illustrate this by showing that the prediction uncertainty of each of six sloppy models varies enormously among different predictions. Statistical approximations of parameter uncertainty may lead to dramatic...

  6. Microholographic imaging of biological samples

    International Nuclear Information System (INIS)

    A camera system suitable for x-ray microholography has been constructed. Visible light Fourier transform microholograms of biological samples and other test targets have been recorded and reconstructed digitally using a glycerol microdrop as a reference wave source. Current results give a resolution of ∼4 - 10 λ with λ = 514.5 nm. 11 refs., 1 fig

  7. Preparation of biological samples for SIMS analyses

    International Nuclear Information System (INIS)

    Full text: For the first time at ANSTO, a program of SIMS analysis of biological samples was undertaken. This presentation will discuss how the wide variety of samples were prepared, and the methods used to gain useful information from SIMS analysis. Lack of matrix-matched standards made quantification difficult, but the strength of SIMS lies in the ability to detect a wide range of stable isotopes with good spatial resolution. This makes the technique suitable for studying organisms that archive signature elements in their structure. Samples such as bivalve shells and crocodile osteoderms were vacuum-impregnated in resin to a size suitable for the SIMS sample holder. Polishing was followed by a sputter coating with gold to alleviate charging of the sample during SIMS analysis. Some samples were introduced directly on the sample holder, either stuck to a glass slide or simply held in place with spring and backing plate. The only treatment in this case was gold coating and degassing in a vacuum pumping station. The porous nature of materials such as leaves and stromatolites requires a period of time under vacuum to remove gases which could interfere with the ultra high vacuum required for SIMS analysis. A calcite standard was used for comparison of oxygen isotopic ratios, but the only matrix-matched standard was available for metal analysis of coral skeletons. Otherwise, the calcium content of the material was assumed to be uniform and acted as an internal standard from which isotopic ratios of other elements could be determined. SIMS analysis of biological samples demonstrated that some matrices could reveal an archive of pollution histories. These samples require matrix-matched standards if the trends observed from analyses are to be quantified

  8. Atomic force microscopy of biological samples.

    Science.gov (United States)

    Allison, David P; Mortensen, Ninell P; Sullivan, Claretta J; Doktycz, Mitchel J

    2010-01-01

    The ability to evaluate structural-functional relationships in real time has allowed scanning probe microscopy (SPM) to assume a prominent role in post genomic biological research. In this mini-review, we highlight the development of imaging and ancillary techniques that have allowed SPM to permeate many key areas of contemporary research. We begin by examining the invention of the scanning tunneling microscope (STM) by Binnig and Rohrer in 1982 and discuss how it served to team biologists with physicists to integrate high-resolution microscopy into biological science. We point to the problems of imaging nonconductive biological samples with the STM and relate how this led to the evolution of the atomic force microscope (AFM) developed by Binnig, Quate, and Gerber, in 1986. Commercialization in the late 1980s established SPM as a powerful research tool in the biological research community. Contact mode AFM imaging was soon complemented by the development of non-contact imaging modes. These non-contact modes eventually became the primary focus for further new applications including the development of fast scanning methods. The extreme sensitivity of the AFM cantilever was recognized and has been developed into applications for measuring forces required for indenting biological surfaces and breaking bonds between biomolecules. Further functional augmentation to the cantilever tip allowed development of new and emerging techniques including scanning ion-conductance microscopy (SICM), scanning electrochemical microscope (SECM), Kelvin force microscopy (KFM) and scanning near field ultrasonic holography (SNFUH). PMID:20672388

  9. Atomic force microscopy of biological samples

    Energy Technology Data Exchange (ETDEWEB)

    Doktycz, Mitchel John [ORNL

    2010-01-01

    The ability to evaluate structural-functional relationships in real time has allowed scanning probe microscopy (SPM) to assume a prominent role in post genomic biological research. In this mini-review, we highlight the development of imaging and ancillary techniques that have allowed SPM to permeate many key areas of contemporary research. We begin by examining the invention of the scanning tunneling microscope (STM) by Binnig and Rohrer in 1982 and discuss how it served to team biologists with physicists to integrate high-resolution microscopy into biological science. We point to the problems of imaging nonconductive biological samples with the STM and relate how this led to the evolution of the atomic force microscope (AFM) developed by Binnig, Quate, and Gerber, in 1986. Commercialization in the late 1980s established SPM as a powerful research tool in the biological research community. Contact mode AFM imaging was soon complemented by the development of non-contact imaging modes. These non-contact modes eventually became the primary focus for further new applications including the development of fast scanning methods. The extreme sensitivity of the AFM cantilever was recognized and has been developed into applications for measuring forces required for indenting biological surfaces and breaking bonds between biomolecules. Further functional augmentation to the cantilever tip allowed development of new and emerging techniques including scanning ion-conductance microscopy (SICM), scanning electrochemical microscope (SECM), Kelvin force microscopy (KFM) and scanning near field ultrasonic holography (SNFUH).

  10. Fluorine ion transmission through thin biological samples

    International Nuclear Information System (INIS)

    F2+ beam with 3 MeV is used to irradiate thin biological samples (onion inner surface membrane and kidney bean coat) in the transmission measurement, its current density is 400∼800 nA/cm2. Results show that the onion samples can be broken up quickly under ion irradiating; as to kidney bean samples, about 60% of the implanted ions penetrate the samples, most of them lose part of their energy, fewer ions are found to be able to transmit through the sample without energy loss. SEM experiments are carried out to study sample's damage induced by the ions irradiation

  11. Fluorine ion transmission through thin biological samples

    Institute of Scientific and Technical Information of China (English)

    XueJian-Ming; WangYu-Gang; 等

    1998-01-01

    F2+ beam with 3MeV is used to irradiate thin biological samples(onion inner suface membrane and kidney bean coat)in the transmission measurement ,its current density is 400-800nA/cm2,Results show that the onion samples can be broken up quickly under ion irradiating;as to kidney bean samples,about 60% of the implanted ions penetrate the samples,most of them lose part of their eneregy,fewer ions are found to be able to transmit through the sample without energy loss.SEM experiments are carried out to study sample's damage induced by the ions irradiation.

  12. Modular microfluidic system for biological sample preparation

    Energy Technology Data Exchange (ETDEWEB)

    Rose, Klint A.; Mariella, Jr., Raymond P.; Bailey, Christopher G.; Ness, Kevin Dean

    2015-09-29

    A reconfigurable modular microfluidic system for preparation of a biological sample including a series of reconfigurable modules for automated sample preparation adapted to selectively include a) a microfluidic acoustic focusing filter module, b) a dielectrophoresis bacteria filter module, c) a dielectrophoresis virus filter module, d) an isotachophoresis nucleic acid filter module, e) a lyses module, and f) an isotachophoresis-based nucleic acid filter.

  13. Discovering biological progression underlying microarray samples.

    Directory of Open Access Journals (Sweden)

    Peng Qiu

    2011-04-01

    Full Text Available In biological systems that undergo processes such as differentiation, a clear concept of progression exists. We present a novel computational approach, called Sample Progression Discovery (SPD, to discover patterns of biological progression underlying microarray gene expression data. SPD assumes that individual samples of a microarray dataset are related by an unknown biological process (i.e., differentiation, development, cell cycle, disease progression, and that each sample represents one unknown point along the progression of that process. SPD aims to organize the samples in a manner that reveals the underlying progression and to simultaneously identify subsets of genes that are responsible for that progression. We demonstrate the performance of SPD on a variety of microarray datasets that were generated by sampling a biological process at different points along its progression, without providing SPD any information of the underlying process. When applied to a cell cycle time series microarray dataset, SPD was not provided any prior knowledge of samples' time order or of which genes are cell-cycle regulated, yet SPD recovered the correct time order and identified many genes that have been associated with the cell cycle. When applied to B-cell differentiation data, SPD recovered the correct order of stages of normal B-cell differentiation and the linkage between preB-ALL tumor cells with their cell origin preB. When applied to mouse embryonic stem cell differentiation data, SPD uncovered a landscape of ESC differentiation into various lineages and genes that represent both generic and lineage specific processes. When applied to a prostate cancer microarray dataset, SPD identified gene modules that reflect a progression consistent with disease stages. SPD may be best viewed as a novel tool for synthesizing biological hypotheses because it provides a likely biological progression underlying a microarray dataset and, perhaps more importantly, the

  14. PIXE and its applications to biological samples

    International Nuclear Information System (INIS)

    Throughout this century, industrialized society has seriously affected the ecology by introducing huge amounts of pollutants into the atmosphere as well as marine and soil environments. On the other hand, it is known that these pollutants, in excess of certain levels of concentration, not only put at risk the life of living beings but may also cause the extinction of some species. It is therefore of basic importance to substantially increase quantitative determinations of trace element concentrations in biological specimens in order to assess the effects of pollutants. It is in this field that PIXE plays a key role in these studies, where its unique analytical properties are decisive. Moreover, since the importance of these research has been recognized in many countries, many scientists have been encouraged to continue or initiate new research programmes aimed to solve the worldwide pollution problem. This document presents an overview of those papers reporting the application of PIXE analysis to biological samples during this last decade of the 20th century and recounts the number of PIXE laboratories dedicating their efforts to find the clues of the biological effects of the presence of pollutants introduced in living beings. Sample preparation methods, different kinds of samples under study and the use of complementary analytical techniques are also illustrated. (author). 108 refs

  15. Fast x-ray fluorescence microtomography of hydrated biological samples.

    Directory of Open Access Journals (Sweden)

    Enzo Lombi

    Full Text Available Metals and metalloids play a key role in plant and other biological systems as some of them are essential to living organisms and all can be toxic at high concentrations. It is therefore important to understand how they are accumulated, complexed and transported within plants. In situ imaging of metal distribution at physiological relevant concentrations in highly hydrated biological systems is technically challenging. In the case of roots, this is mainly due to the possibility of artifacts arising during sample preparation such as cross sectioning. Synchrotron x-ray fluorescence microtomography has been used to obtain virtual cross sections of elemental distributions. However, traditionally this technique requires long data acquisition times. This has prohibited its application to highly hydrated biological samples which suffer both radiation damage and dehydration during extended analysis. However, recent advances in fast detectors coupled with powerful data acquisition approaches and suitable sample preparation methods can circumvent this problem. We demonstrate the heightened potential of this technique by imaging the distribution of nickel and zinc in hydrated plant roots. Although 3D tomography was still impeded by radiation damage, we successfully collected 2D tomograms of hydrated plant roots exposed to environmentally relevant metal concentrations for short periods of time. To our knowledge, this is the first published example of the possibilities offered by a new generation of fast fluorescence detectors to investigate metal and metalloid distribution in radiation-sensitive, biological samples.

  16. Strategies for Field Sampling When Large Sample Sizes are Required

    Science.gov (United States)

    Estimates of prevalence or incidence of infection with a pathogen endemic in a fish population can be valuable information for development and evaluation of aquatic animal health management strategies. However, hundreds of unbiased samples may be required in order to accurately estimate these parame...

  17. Biological sampling for marine radioactivity monitoring

    International Nuclear Information System (INIS)

    Strategies and methodologies for using marine organisms to monitor radioactivity in marine waters are presented. When the criteria for monitoring radioactivity is to determine routes of radionuclide transfer to man, the ''critical pathway'' approach is often applied. Alternatively, where information on ambient radionuclide levels and distributions is sought, the approach of selecting marine organisms as ''bioindicators'' of radioactivity is generally used. Whichever approach is applied, a great deal of knowledge is required about the physiology and ecology of the specific organism chosen. In addition, several criteria for qualifying as a bioindicator species are discussed; e.g., it must be a sedentary species which reflects the ambient radionuclide concentration at a given site, sufficiently long-lived to allow long-term temporal sampling, widely distributed to allow spatial comparisons, able to bioconcentrate the radionuclide to a relatively high degree, while showing a simple correlation between radionuclide content in its tissues with that in the surrounding waters. Useful hints on the appropriate species to use and the best way to collect and prepare organisms for radioanalysis are also given. It is concluded that benthic algae and bivalve molluscs generally offer the greatest potential for use as a ''bioindicator'' species in radionuclide biomonitoring programmes. Where knowledge on contribution to radiological dose is required, specific edible marine species should be the organisms of choice; however, both purposes can be served when the edible species chosen through critical pathway analysis is also an excellent bioaccumulator of the radionuclide of interest. (author)

  18. Biological and Environmental Research Network Requirements

    Energy Technology Data Exchange (ETDEWEB)

    Balaji, V. [Princeton Univ., NJ (United States). Earth Science Grid Federation (ESGF); Boden, Tom [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Cowley, Dave [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Dart, Eli [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States). ESNet; Dattoria, Vince [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States). ESNet; Desai, Narayan [Argonne National Lab. (ANL), Argonne, IL (United States); Egan, Rob [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Foster, Ian [Argonne National Lab. (ANL), Argonne, IL (United States); Goldstone, Robin [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Gregurick, Susan [U.S. Dept. of Energy, Washington, DC (United States). Biological Systems Science Division; Houghton, John [U.S. Dept. of Energy, Washington, DC (United States). Biological and Environmental Research (BER) Program; Izaurralde, Cesar [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Johnston, Bill [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States). ESNet; Joseph, Renu [U.S. Dept. of Energy, Washington, DC (United States). Climate and Environmental Sciences Division; Kleese-van Dam, Kerstin [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Lipton, Mary [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Monga, Inder [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States). ESNet; Pritchard, Matt [British Atmospheric Data Centre (BADC), Oxon (United Kingdom); Rotman, Lauren [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States). ESNet; Strand, Gary [National Center for Atmospheric Research (NCAR), Boulder, CO (United States); Stuart, Cory [Argonne National Lab. (ANL), Argonne, IL (United States); Tatusova, Tatiana [National Inst. of Health (NIH), Bethesda, MD (United States); Tierney, Brian [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States). ESNet; Thomas, Brian [Univ. of California, Berkeley, CA (United States); Williams, Dean N. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Zurawski, Jason [Internet2, Washington, DC (United States)

    2013-09-01

    The Energy Sciences Network (ESnet) is the primary provider of network connectivity for the U.S. Department of Energy (DOE) Office of Science (SC), the single largest supporter of basic research in the physical sciences in the United States. In support of SC programs, ESnet regularly updates and refreshes its understanding of the networking requirements of the instruments, facilities, scientists, and science programs that it serves. This focus has helped ESnet be a highly successful enabler of scientific discovery for over 25 years. In November 2012, ESnet and the Office of Biological and Environmental Research (BER) of the DOE SC organized a review to characterize the networking requirements of the programs funded by the BER program office. Several key findings resulted from the review. Among them: 1) The scale of data sets available to science collaborations continues to increase exponentially. This has broad impact, both on the network and on the computational and storage systems connected to the network. 2) Many science collaborations require assistance to cope with the systems and network engineering challenges inherent in managing the rapid growth in data scale. 3) Several science domains operate distributed facilities that rely on high-performance networking for success. Key examples illustrated in this report include the Earth System Grid Federation (ESGF) and the Systems Biology Knowledgebase (KBase). This report expands on these points, and addresses others as well. The report contains a findings section as well as the text of the case studies discussed at the review.

  19. Coherence and sampling requirements for diffractive imaging

    International Nuclear Information System (INIS)

    Coherent Diffractive Imaging (CDI) allows images to be reconstructed from diffraction patterns by solving the non-crystallographic phase problem for isolated nanostructures. We show that the Shannon sampling of diffraction intensities needed in CDI requires a coherence width about twice the lateral dimensions of the object, and that the linear number of detector pixels fixes the energy spread needed in the beam. The Shannon sampling, defined by the transform of the periodically repeated autocorrelation of the object, is related to Bragg scattering from an equivalent crystal, and shown to be consistent with the sampling of Young's fringes established by scattering from extreme points in the object. The results are relevant to the design of diffraction cameras for CDI and plans for femotosecond X-ray diffraction from individual proteins

  20. Biological Sample Ambient Preservation (BioSAP) Device Project

    Data.gov (United States)

    National Aeronautics and Space Administration — To address NASA's need for alternative methods for ambient preservation of human biological samples collected during extended spaceflight and planetary operations,...

  1. Predicting sample size required for classification performance

    Directory of Open Access Journals (Sweden)

    Figueroa Rosa L

    2012-02-01

    Full Text Available Abstract Background Supervised learning methods need annotated data in order to generate efficient models. Annotated data, however, is a relatively scarce resource and can be expensive to obtain. For both passive and active learning methods, there is a need to estimate the size of the annotated sample required to reach a performance target. Methods We designed and implemented a method that fits an inverse power law model to points of a given learning curve created using a small annotated training set. Fitting is carried out using nonlinear weighted least squares optimization. The fitted model is then used to predict the classifier's performance and confidence interval for larger sample sizes. For evaluation, the nonlinear weighted curve fitting method was applied to a set of learning curves generated using clinical text and waveform classification tasks with active and passive sampling methods, and predictions were validated using standard goodness of fit measures. As control we used an un-weighted fitting method. Results A total of 568 models were fitted and the model predictions were compared with the observed performances. Depending on the data set and sampling method, it took between 80 to 560 annotated samples to achieve mean average and root mean squared error below 0.01. Results also show that our weighted fitting method outperformed the baseline un-weighted method (p Conclusions This paper describes a simple and effective sample size prediction algorithm that conducts weighted fitting of learning curves. The algorithm outperformed an un-weighted algorithm described in previous literature. It can help researchers determine annotation sample size for supervised machine learning.

  2. Uranium-233 analysis of biological samples

    International Nuclear Information System (INIS)

    Two liquid scintillation techniques were compared for 233U analysis: a two-phase extraction system (D2EHPA) developed by Keough and Powers, 1970, for Pu analysis; and a single-phase emulsion system (TT21) that holds the total sample in suspension with the scintillator. The first system (D2EHPA) was superior in reducing background (two- to threefold) and in accommodating a larger sample volume (fivefold). Samples containing > 50 mg/ml of slats were not extracted quantitatively by D2EHPA

  3. PIXE - Analysis for environmental and biological samples

    International Nuclear Information System (INIS)

    The usefulness and accuracy of PIXE as an analytical tool in the study of trace elements in environmental samples of the Brazilian Cerrado are discussed. The report lists actual and forthcoming publications resulting from the study. The mechanism of exchange of elements in solution in water to aerosols has been investigated. For details of the procedure the reader is referred to an earlier report

  4. Microradiagraphy of biological samples with Timepix

    Czech Academy of Sciences Publication Activity Database

    Dammer, J.; Weyda, František; Beneš, J.; Sopko, V.; Jakůbek, J.; Vondráček, V.

    2011-01-01

    Roč. 6, C11005 (2011), s. 1-6. ISSN 1748-0221. [International workshop on radiation imaging detectors /13./. Zurich, 03.07.2011-07.07.2011] R&D Projects: GA MŠk 2B06005 Grant ostatní: GA MŠk(CZ) LC06041; GA AV ČR(CZ) IAA600550614; GA MŠk(CZ) 2B06007; Research Program(CZ) 6840770029; Research Program(CZ) 6840770040; GA MŠk-spolupráce s CERN(CZ) 1P04LA211 Institutional research plan: CEZ:AV0Z50070508 Keywords : X-ray detectors * X-ray radiography and digital radiography (DR) * pixelated detectors and associated VLSI electronics Subject RIV: EA - Cell Biology Impact factor: 1.869, year: 2011 http://iopscience.iop.org/1748-0221/6/11/C11005/pdf/1748-0221_6_11_C11005.pdf

  5. Biological sample preparation and 41Ca AMS measurement at LLNL

    International Nuclear Information System (INIS)

    Calcium metabolism in biology may be better understood by the use of 41Ca tracer, although requiring detection by accelerator mass spectrometry (AMS). Methodologies for preparation of urine samples and subsequent AMS measurement were investigated. Novel attempts at preparing CaH2 were unsuccessful, but CaF2 of sufficient purity could be produced by precipitation of calcium from urine as oxalate, followed by separation of calcium by cation exchange chromatography and washing the CaF2 precipitate. The presence of some remaining impurities could be compensated for by selecting the appropriate accelerated ion charge state for AMS. The use of projectile X-rays for isobar discrimination was explored as an alternative to the co nventional dE/dx detector. (orig.)

  6. Manipulation of biological samples using micro and nano techniques

    DEFF Research Database (Denmark)

    Castillo, Jaime; Dimaki, Maria; Svendsen, Winnie Edith

    2009-01-01

    The constant interest in handling, integrating and understanding biological systems of interest for the biomedical field, the pharmaceutical industry and the biomaterial researchers demand the use of techniques that allow the manipulation of biological samples causing minimal or no damage to thei...

  7. Micro and Nano Techniques for the Handling of Biological Samples

    DEFF Research Database (Denmark)

    Micro and Nano Techniques for the Handling of Biological Samples reviews the different techniques available to manipulate and integrate biological materials in a controlled manner, either by sliding them along a surface (2-D manipulation), or by gripping and moving them to a new position (3-D...

  8. Efficient Sample Preparation from Complex Biological Samples Using a Sliding Lid for Immobilized Droplet Extractions

    OpenAIRE

    Casavant, Benjamin P.; Guckenberger, David J.; Beebe, David J.; Berry, Scott M

    2014-01-01

    Sample preparation is a major bottleneck in many biological processes. Paramagnetic particles (PMPs) are a ubiquitous method for isolating analytes of interest from biological samples and are used for their ability to thoroughly sample a solution and be easily collected with a magnet. There are three main methods by which PMPs are used for sample preparation: (1) removal of fluid from the analyte-bound PMPs, (2) removal of analyte-bound PMPs from the solution, and (3) removal of the substrate...

  9. [Critical aspects in determining total radioactivity of biological samples].

    Science.gov (United States)

    Del Vecchio, M P; Paolini, M; Corsi, C; Bauer, C

    1989-03-01

    During measurements of radioactivity in some milk samples with liquid scintillation counter (about one year after the nuclear accident of Chernobyl) we have observed an increase of the values of scintillation fluid with the passing of time. Although this enhancement is absolutely small (about 2 c.p.m. in 500 min), it is very important for an exact measurement of samples at low counting, as those tested. Our protocol of measure provides for insertion of alternate blanks and samples in the automatic sample-holders of liquid scintillation counter. The values of measurement of samples are taken during the increase phase subtracting the value of blank interpolated on the increasing straight line from c.p.m. of sample. Finally, we report the collected values of the whole radioactivity in some milk samples: at least 5-6 nCi/L contrary to about 1 nCi/L of 137Cs reported by USL. In our opinion it is important to consider the whole radioactivity as measure of the overall biological danger of radioactive samples. In fact, this measurement takes into account also biologically very dangerous radionuclides as 3H, 14C, 90Sr. PMID:2765252

  10. Sampling and sample preparation methods for the analysis of trace elements in biological material

    International Nuclear Information System (INIS)

    The authors attempt to give a most systamtic possible treatment of the sample taking and sample preparation of biological material (particularly in human medicine) for trace analysis (e.g. neutron activation analysis, atomic absorption spectrometry). Contamination and loss problems are discussed as well as the manifold problems of the different consistency of solid and liquid biological materials, as well as the stabilization of the sample material. The process of dry and wet ashing is particularly dealt with, where new methods are also described. (RB)

  11. Overview of Mars Sample Hazard Analysis (Requirements Workshop Series)

    Science.gov (United States)

    Rummel, John D.

    2000-01-01

    Samples returned from Mars should be contained and treated as though potentially hazardous until proven otherwise. If sample containment cannot be verified en route to Earth, the sample and spacecraft should either be sterilized in space or not returned to Earth. Integrity of sample containment should be maintained through reentry and transfer to a receiving facility. Controlled distribution of unsterilized materials should only occur if analyses determine the sample not to contain a biological hazard. Planetary protection measures adopted for the first sample return should not be relaxed for subsequent missions without thorough scientific review and concurrence by an appropriate independent body.

  12. 40 CFR 141.22 - Turbidity sampling and analytical requirements.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 22 2010-07-01 2010-07-01 false Turbidity sampling and analytical... PROGRAMS (CONTINUED) NATIONAL PRIMARY DRINKING WATER REGULATIONS Monitoring and Analytical Requirements § 141.22 Turbidity sampling and analytical requirements. The requirements in this section apply...

  13. Preparation of Biological Samples Containing Metoprolol and Bisoprolol for Applying Methods for Quantitative Analysis

    Directory of Open Access Journals (Sweden)

    Corina Mahu Ştefania

    2015-12-01

    Full Text Available Arterial hypertension is a complex disease with many serious complications, representing a leading cause of mortality. Selective beta-blockers such as metoprolol and bisoprolol are frequently used in the management of hypertension. Numerous analytical methods have been developed for the determination of these substances in biological fluids, such as liquid chromatography coupled with mass spectrometry, gas chromatography coupled with mass spectrometry, high performance liquid chromatography. Due to the complex composition of biological fluids a biological sample pre-treatment before the use of the method for quantitative determination is required in order to remove proteins and potential interferences. The most commonly used methods for processing biological samples containing metoprolol and bisoprolol were identified through a thorough literature search using PubMed, ScienceDirect, and Willey Journals databases. Articles published between years 2005-2015 were reviewed. Protein precipitation, liquid-liquid extraction and solid phase extraction are the main techniques for the extraction of these drugs from plasma, serum, whole blood and urine samples. In addition, numerous other techniques have been developed for the preparation of biological samples, such as dispersive liquid-liquid microextraction, carrier-mediated liquid phase microextraction, hollow fiber-protected liquid phase microextraction, on-line molecularly imprinted solid phase extraction. The analysis of metoprolol and bisoprolol in human plasma, urine and other biological fluids provides important information in clinical and toxicological trials, thus requiring the application of appropriate extraction techniques for the detection of these antihypertensive substances at nanogram and picogram levels.

  14. Activation Analysis of Biological Samples of Forensic Interest

    International Nuclear Information System (INIS)

    In forensic (crime investigation) studies, samples of a biological origin are frequently used as evidence. Often it is necessary to compare one sample (associated with a victim or the scene of a crime) with another sample of the same general type (associated with a suspect in some way). The purpose of such comparisons is to establish, if possible, that - to a high degree of probability - the two samples have a common origin. Typically, all available relevant methods of comparison are utilized in such cases by the criminalist: microscopic examination; X-ray diffraction; infra-red, visible, and ultra-violet spectrometry; and various methods of elemental analysis. The forensic applications of high-flux thermal-neutron activation analysis (NAA) have shown great promise and are attracting considerable attention. The authors' laboratory has been engaged in such forensic NAA research and development studies for the past five years. (It also operates a non-profit Forensic Activation Analysis Service, available to all law enforcement agencies, for the NAA comparison of evidence samples involved in actual criminal cases. Samples from many actual cases have been thus examined.) In the United States, NAA results have now been successfully presented in court in some 20 actual cases. Some of the evidence-type materials of interest are non-biological; others are biological. Only the latter will be discussed in this paper. The principal evidence-type materials of a biological nature that have been examined in this laboratory by high-flux thermal-NAA to date are the following: hair, blood, faeces, urine, fingernails, skin, wood, tobacco, whisky, green plants, and marijuana. (In addition, a number of these evidence-type materials have also been studied in this laboratory by high-flux photonuclear activation analysis (PNAA); attention in this paper will be largely devoted to the thermal-NAA forensic studies.) The main topics to be reported upon in this paper are: (1) limits of

  15. 1330-N Waste Handling Facility waste designation sampling requirements

    International Nuclear Information System (INIS)

    This sampling and analysis requirements document details the protocols and responsibilities required to perform sampling and field screening for waste designation purposes. This Sampling and Analysis Plan (SAP) covers sample collection, field screening, sample analysis, sample shipping, and final report preparation for the characterization and designation of waste at the 1330-N Waste Handling Facility. At the direction of Field Support Waste Management (FSWM), this SAP may be used for sampling/field screening efforts at locations other than the 1330-N Waste Handling Facility

  16. Toxicological Analysis of Some Drugs of Abuse in Biological Samples

    Directory of Open Access Journals (Sweden)

    Anne Marie Ciobanu

    2015-10-01

    Full Text Available Consumption of drugs of abuse is a scourge of modern world. Abuse, drug addiction and their consequences are one of the major current problems of European society because of the significant repercussions in individual, family, social and economic level. In this context, toxicological analysis of the drugs of abuse in biological samples is a useful tool for: diagnosis of drug addiction, checking an auto-response, mandatory screening in some treatment programs, identification of a substance in the case of an overdose, determining compliance of the treatment. The present paper aims to address the needs of healthcare professionals involved in drugs addiction treatment through systematic presentation of information regarding their toxicological analysis. Basically, it is a tool that help you to select the suitable biological sample and the right collecting time, as well as the proper analysis technique, depending on the purpose of analysis, pharmacokinetic characteristics of the drugs of abuse, available equipment and staff expertise.

  17. Incubation Station for the Bacterial Growth Study in Biological Samples

    OpenAIRE

    Carlos Rafael Duharte Rodríguez; Ibrain Ceballo Acosta; Carmen B. Busoch Morlán; Ángel Regueiro Gómez

    2015-01-01

    This work shows the designing and characterization of a prototype of laboratory incubator as support of Microbiology research, in particular for the research of the bacterial growth in biological samples through optic methods (Turbidimetry) and electrometric measurements of bioimpedance. It shows the results of simulation and experimentation of the design proposed for the canals of measurement of the variables: temperature and humidity, with a high linearity from the adequate selection of the...

  18. Toxicological Analysis of Some Drugs of Abuse in Biological Samples

    OpenAIRE

    Anne Marie Ciobanu; Daniela Baconi; Cristian Bălălău; Carolina Negrei; Miriana Stan; Maria Bârcă

    2015-01-01

    Consumption of drugs of abuse is a scourge of modern world. Abuse, drug addiction and their consequences are one of the major current problems of European society because of the significant repercussions in individual, family, social and economic level. In this context, toxicological analysis of the drugs of abuse in biological samples is a useful tool for: diagnosis of drug addiction, checking an auto-response, mandatory screening in some treatment programs, identification of a substance ...

  19. Measurement of n-alkanals and hydroxyalkenals in biological samples.

    Science.gov (United States)

    Holley, A E; Walker, M K; Cheeseman, K H; Slater, T F

    1993-09-01

    A modified method was developed to measure nM levels of a range of n-alkanals and hydroxyalkenals in biological samples such as blood plasma and tissue homogenates and also in Folch lipid extracts of these samples. Butylated hydroxytoluene (BHT) and desferrioxamine (Desferal) were added to samples to prevent artifactual peroxidation. Aldehydes were reacted with 1,3-cyclohexanedione (CHD), cleaned up by solid-phase extraction on a Sep-Pak C18 cartridge and the fluorescent decahydroacridine derivatives resolved by reverse-phase high-performance liquid chromatography (HPLC) with gradient elution. A wider range of aldehydes was detected in lipid extracts of plasma and liver homogenate compared to whole (unextracted) samples. Human plasma contained nM levels of acetaldehyde, propanal, butanal, pentanal, hexanal, and heptanal. 4-Hydroxynonenal (0.93 nmol/g) and alkanals with two to six carbons (up to 7.36 nmol/g) were detected in rat liver. Recovery of aldehydes added to whole plasma or to lipid extracts of plasma was dependent on carbon chain length, varying from 95% for acetaldehyde to 8% for decanal. Recovery from biological samples was significantly less than that of standards taken through the Sep-Pak clean-up procedure, suggesting that aldehydes can bind to plasma protein and lipid components. PMID:8406128

  20. Chiral speciation of selenoamino acids in biological samples.

    Science.gov (United States)

    Chen, Beibei; He, Man; Zhong, Cheng; Hu, Bin

    2014-10-10

    In this paper, the "state of the art" of chiral speciation of selenoamino acids (SeAAs) in biological samples is critically reviewed. The significance and the features of such studies are highlighted. A special focus lies on chiral speciation of SeAAs by hyphenation techniques in which a chiral separation method (such as gas chromatography (GC), high performance liquid chromatography (HPLC) and capillary electrophoresis (CE)) is on-line coupled with an elemental specific detector, especially inductively coupled plasma mass spectrometry (ICP-MS). The advances in the development and application of hyphenation techniques in chiral speciation of SeAAs in biological samples are summarized and a perspective for future developments including sophisticated and innovative applications is discussed. Overall, HPLC-ICP-MS is more applicable than GC/CE-ICP-MS for chiral speciation of SeAAs. In the future, more novel chiral HPLC methods with high enantio-resolution, low cost and robustness, and their more applications in real biological samples analysis are expected. PMID:25130085

  1. Approximate sample sizes required to estimate length distributions

    Science.gov (United States)

    Miranda, L.E.

    2007-01-01

    The sample sizes required to estimate fish length were determined by bootstrapping from reference length distributions. Depending on population characteristics and species-specific maximum lengths, 1-cm length-frequency histograms required 375-1,200 fish to estimate within 10% with 80% confidence, 2.5-cm histograms required 150-425 fish, proportional stock density required 75-140 fish, and mean length required 75-160 fish. In general, smaller species, smaller populations, populations with higher mortality, and simpler length statistics required fewer samples. Indices that require low sample sizes may be suitable for monitoring population status, and when large changes in length are evident, additional sampling effort may be allocated to more precisely define length status with more informative estimators. ?? Copyright by the American Fisheries Society 2007.

  2. 40 CFR 141.174 - Filtration sampling requirements.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 22 2010-07-01 2010-07-01 false Filtration sampling requirements. 141... PROGRAMS (CONTINUED) NATIONAL PRIMARY DRINKING WATER REGULATIONS Enhanced Filtration and Disinfection-Systems Serving 10,000 or More People § 141.174 Filtration sampling requirements. (a)...

  3. Sample preparation techniques of biological material for isotope analysis

    International Nuclear Information System (INIS)

    Sample preparation is an essential step in all isotope-aided experiments but often it is not given enough attention. The methods of sample preparation are very important to obtain reliable and precise analytical data and for further interpretation of results. The size of a sample required for chemical analysis is usually very small (10mg-1500mg). On the other hand the amount of harvested plant material from plots in a field experiment is often bulky (several kilograms) and the entire sample is too large for processing. In addition, while approaching maturity many crops show not only differences in physical consistency but also a non-uniformity in 15N content among plant parts, requiring a plant fractionation or separation into parts (vegetative and reproductive) e.g. shoots and spikes, in case of small grain cereals, shoots and pods in case of grain legumes and tops and roots or beets (including crown) in case of sugar beet, etc. In any case the ultimate goal of these procedures is to obtain representative subsample harvested from greenhouse or field experiments for chemical analysis. Before harvesting an isotopic-aided experiment the method of sampling has to be selected. It should be based on the type of information required in relation to the objectives of the research and the availability of resources (staff, sample preparation equipment, analytical facilities, chemicals and supplies, etc.). 10 refs, 3 figs, 3 tabs

  4. Determinate the BPA in biological samples by spectrophotometry

    International Nuclear Information System (INIS)

    Boron neutron capture therapy (BNCT) is a new radiation therapy, of which clinical interest has focused primarily on the treatment of high-grade gliomas. At present, the most effective drug for BNCT is p-Boronophenylalanine (BPA), because it has little side effect and low toxicity, persisted longer in tumors compared with related molecules. The method of 3-Methoxy-Methylenimine H spectrophotometry was established to measure the concentration of 10B in biological samples. The biodistribution of the BPA was studied in normal mice. (authors)

  5. Incubation Station for the Bacterial Growth Study in Biological Samples

    Directory of Open Access Journals (Sweden)

    Carlos Rafael Duharte Rodríguez

    2015-12-01

    Full Text Available This work shows the designing and characterization of a prototype of laboratory incubator as support of Microbiology research, in particular for the research of the bacterial growth in biological samples through optic methods (Turbidimetry and electrometric measurements of bioimpedance. It shows the results of simulation and experimentation of the design proposed for the canals of measurement of the variables: temperature and humidity, with a high linearity from the adequate selection of the corresponding sensors and the analogue components of every canal, controlled with help of a microcontroller AT89C51 (ATMEL with adequate benefi ts for this type of application.

  6. Ethanol analysis from biological samples by dual rail robotic autosampler.

    Science.gov (United States)

    Morris-Kukoski, Cynthia L; Jagerdeo, Eshwar; Schaff, Jason E; LeBeau, Marc A

    2007-05-01

    Detection, identification, and quantitation of ethanol and other low molecular weight volatile compounds in liquid matrices by headspace gas chromatography-flame ionization detection (HS-GC-FID) and headspace gas chromatography-mass spectrometry (HS-GC-MS) are becoming commonly used practices in forensic laboratories. Although it is one of the most frequently utilized procedures, sample preparation is usually done manually. Implementing the use of a dual-rail, programmable autosampler can minimize many of the manual steps in sample preparation. The autosampler is configured so that one rail is used for sample preparation and the other rail is used as a traditional autosampler for sample introduction into the gas chromatograph inlet. The sample preparation rail draws up and sequentially adds a saturated sodium chloride solution and internal standard (0.08%, w/v acetonitrile) to a headspace vial containing a biological sample, a calibrator, or a control. Then, the analytical rail moves the sample to the agitator for incubation, followed by sampling of the headspace for analysis. Using DB-624 capillary columns, the method was validated on a GC-FID and confirmed with a GC-MS. The analytes (ethanol, acetonitrile) and possible interferences (acetaldehyde, methanol, pentane, diethyl ether, acetone, isopropanol, methylene chloride, n-propanol, and isovaleraldehyde) were baseline resolved for both the GC-FID and GC-MS methods. This method demonstrated acceptable linearity from 0 to 1500 mg/dL. The lower limit of quantitation (LOQ) was determined to be 17 mg/dL and the limit of detection was 5 mg/dL. PMID:17223393

  7. Explaining Choice and Share of Category Requirements of Biologic Meat

    NARCIS (Netherlands)

    P.C. Verhoef (Peter); K. Vlagsma-Brangule (Kristine)

    2003-01-01

    textabstractIn this paper we examine factors determining choice and consumption of biologic or organic meat. In our model explaining choice and share of category requirements, we consider economic/marketing variables (quality, price, and distribution), emotions (fear, empathy, andguilt), social norm

  8. Microsystem strategies for sample preparation in biological detection.

    Energy Technology Data Exchange (ETDEWEB)

    James, Conrad D.; Galambos, Paul C.; Bennett, Dawn Jonita (University of Maryland Baltimore County, Baltimore, MD); Manginell, Monica; Okandan, Murat; Acrivos, Andreas (The City College of New York, NY); Brozik, Susan Marie; Khusid, Boris (New Jersey Institute of Technology, Newark, NJ)

    2005-03-01

    The objective of this LDRD was to develop microdevice strategies for dealing with samples to be examined in biological detection systems. This includes three sub-components: namely, microdevice fabrication, sample delivery to the microdevice, and sample processing within the microdevice. The first component of this work focused on utilizing Sandia's surface micromachining technology to fabricate small volume (nanoliter) fluidic systems for processing small quantities of biological samples. The next component was to develop interfaces for the surface-micromachined silicon devices. We partnered with Micronics, a commercial company, to produce fluidic manifolds for sample delivery to our silicon devices. Pressure testing was completed to examine the strength of the bond between the pressure-sensitive adhesive layer and the silicon chip. We are also pursuing several other methods, both in house and external, to develop polymer-based fluidic manifolds for packaging silicon-based microfluidic devices. The second component, sample processing, is divided into two sub-tasks: cell collection and cell lysis. Cell collection was achieved using dielectrophoresis, which employs AC fields to collect cells at energized microelectrodes, while rejecting non-cellular particles. Both live and dead Staph. aureus bacteria have been collected using RF frequency dielectrophoresis. Bacteria have been separated from polystyrene microspheres using frequency-shifting dielectrophoresis. Computational modeling was performed to optimize device separation performance, and to predict particle response to the dielectrophoretic traps. Cell lysis is continuing to be pursued using microactuators to mechanically disrupt cell membranes. Novel thermal actuators, which can generate larger forces than previously tested electrostatic actuators, have been incorporated with and tested with cell lysis devices. Significant cell membrane distortion has been observed, but more experiments need to be

  9. The use of contrast agent for imaging biological samples

    Energy Technology Data Exchange (ETDEWEB)

    Dammer, J; Sopko, V; Jakubek, J [Institute of Experimental and Applied Physics, Czech Technical University in Prague, Horska 3a/22, CZ 12800 Prague 2 (Czech Republic); Weyda, F, E-mail: jiri.dammer@utef.cvut.cz [Biological center of the Academy of Sciences of the Czech Republic, Institute of Entomology, Branisovska 31, CZ-37005 Ceske Budejovice (Czech Republic)

    2011-01-15

    The technique of X-ray transmission imaging has been available for over a century and is still among the fastest and easiest approaches to the studies of internal structure of biological samples. Recent advances in semiconductor technology have led to the development of new types of X-ray detectors with direct conversion of interacting X-ray photon to an electric signal. Semiconductor pixel detectors seem to be specially promising; compared to the film technique, they provide single-quantum and real-time digital information about the objects being studied. We describe the recently developed radiographic apparatus, equipped with Medipix2 semiconductor pixel detector. The detector is used as an imager that counts individual photons of ionizing radiation, emitted by an X-ray tube (micro- or nano-focus FeinFocus). Thanks to the wide dynamic range of the Medipix2 detector and its high spatial resolution better than 1{mu}m, the setup is particularly suitable for radiographic imaging of small biological samples, including in-vivo observations with contrast agent (Optiray). Along with the description of the apparatus we provide examples of the use iodine contrast agent as a tracer in various insects as model organisms. The motivation of our work is to develop our imaging techniques as non-destructive and non-invasive. Microradiographic imaging helps detect organisms living in a not visible environment, visualize the internal biological processes and also to resolve the details of their body (morphology). Tiny live insects are an ideal object for our studies.

  10. The measurement of radioactive microspheres in biological samples

    International Nuclear Information System (INIS)

    Measurements of the distribution of radioactive microspheres are used in investigations of regional coronary blood flow, but the size and shape of the heart varies for different test animals, and the organ is frequently divided into smaller pieces for studies of regional perfusion. Errors are introduced by variations in the distribution of the radioactive source and the amount of Compton scatter in different samples. A technique has therefore been developed to allow the counting of these tissue samples in their original form, and correction factors have been derived to inter-relate the various counting geometries thus encountered. Dogs were injected with microspheres labelled with 141Ce, 51Cr or 85Sr. The tissue samples did not require remodelling to fit a standard container, and allowance was made for the inhomogeneous distribution in the blood samples. The activities in the centrifuged blood samples were correlated with those from the tissue samples by a calibration procedure involving comparisons of the counts from samples of microspheres embedded in sachets of gelatine, and similar samples mixed with blood and then centrifuged. The calibration data have indicated that 51Cr behaves anomalously, and its use as a label for microspheres may introduce unwarranted errors. A plane cylindrical 10 x 20 cm NaI detector was used, and a 'worst case' correction of 20% was found to be necessary for geometry effects. The accuracy of this method of correlating different geometries was tested by remodelling the same tissue sample into different sizes and comparing the results, and the validity of the technique was supported by agreement of the final results with previously published data. (U.K.)

  11. Spectroscopic analysis of bosentan in biological samples after a liquid-liquid microextraction

    Science.gov (United States)

    Sajedi-Amin, Sanaz; Assadpour-Zeynali, Karim; Panahi-Azar, Vahid; Kebriaeezadeh, Abbas; Khoubnasabjafari, Maryam; Ansarin, Khalil; Jouyban-Gharamaleki, Vahid; Jouyban, Abolghasem

    2015-01-01

    Introduction:Microextraction processes with UV-Vis measurement have been developed and validated for analysis of bosentan in biological samples. Methods:In this work, liquid–liquid microextraction procedures (DLLME & USAEME) were employed for cleanup, pre-concentration, and determination of bosentan in biological samples by UV-Vis spectroscopy at 270 nm. The method was validated and applied to the determination of bosentan in spiked serum, exhaled breath condensate and urine samples. Results:Various experimental factors including type of extraction and dispersive solvents and their volumes, pH, sonication time and centrifuging time were investigated. Under the optimum conditions, the method was linear in the range of 1.0–5.0 μg.mL-1, with coefficient of determination (R2) of > 0.998. The limit of detection (LOD) was 0.07 mg.L-1. Recovery of the target analyte in biological samples was 106.2%. The method could be easily applied for higher concentration of bosentan and needs more improvement for application in the pharmacokinetic investigations where more sensitive methods are required. Conclusion:A simple, low cost, precise and accurate spectrophotometric analysis of bosentan in biological samples after liquid-liquid microextraction were developed and validated for routine analyses. PMID:26929923

  12. Recommendations for sampling for prevention of hazards in civil defense. On analytics of chemical, biological and radioactive contaminations. Brief instruction for the CBRN (chemical, biological, radioactive, nuclear) sampling

    International Nuclear Information System (INIS)

    The recommendation for sampling for prevention of hazards in civil defense is describing the analytics of chemical, biological and radioactive contaminations and includes detail information on the sampling, protocol preparation and documentation procedures. The volume includes a separate brief instruction for the CBRN (chemical, biological, radioactive, nuclear) sampling.

  13. Micro-radiography of biological samples with medical contrast agents

    Energy Technology Data Exchange (ETDEWEB)

    Dammer, J., E-mail: jiri.dammer@lf1.cuni.cz [Charles University in Prague, First Faculty of Medicine, Salmovská 1, 120 00 Prague 2 (Czech Republic); Hospital Na Bulovce, Department of Radiological Physics, Budinova 2, 180 81 Prague 8 (Czech Republic); Institute of Experimental and Applied Physics, Czech Technical University in Prague, Horska 3a/22, 128 00 Prague 2 (Czech Republic); Weyda, F. [Faculty of Science, University of South Bohemia, Branisovska 31, 370 05 Ceske Budejovice (Czech Republic); Benes, J. [Charles University in Prague, First Faculty of Medicine, Salmovská 1, 120 00 Prague 2 (Czech Republic); Sopko, V. [Hospital Na Bulovce, Department of Radiological Physics, Budinova 2, 180 81 Prague 8 (Czech Republic); Institute of Experimental and Applied Physics, Czech Technical University in Prague, Horska 3a/22, 128 00 Prague 2 (Czech Republic); Gelbic, I. [Biology Centre, AS CR, Institute of Entomology, Department of Biochemistry and Physiology, Branisovska 31, CZ-37005 Ceske Budejovice (Czech Republic)

    2013-12-01

    Micro-radiography is an imaging technique that uses X-rays to study the internal structures of objects. This fast and easy imaging tool is based on differential X-ray attenuation by various tissues and structures within biological samples. The experimental setup described is based on the semiconductor pixel X-ray detector Medipix2 and X-ray micro-focus tube. Our micro-radiographic system has been recently used not only for the examination of internal structures of various arthropods and other biological objects but also for tracing some processes in selected model species (we used living larvae of mosquito Culex quinquefasciatus). Low concentrations of iodine, lanthanum or gold particles were used as a tracer (contrast agent). Such contrast agents increase the absorption of X-rays and allow a better visibility of internal structures of model organisms (especially the various cavities, pores, etc.). In addition, the movement of tracers in selected timing experiments demonstrates some physiological functions of digestive and excretory system.

  14. Micro-radiography of biological samples with medical contrast agents

    International Nuclear Information System (INIS)

    Micro-radiography is an imaging technique that uses X-rays to study the internal structures of objects. This fast and easy imaging tool is based on differential X-ray attenuation by various tissues and structures within biological samples. The experimental setup described is based on the semiconductor pixel X-ray detector Medipix2 and X-ray micro-focus tube. Our micro-radiographic system has been recently used not only for the examination of internal structures of various arthropods and other biological objects but also for tracing some processes in selected model species (we used living larvae of mosquito Culex quinquefasciatus). Low concentrations of iodine, lanthanum or gold particles were used as a tracer (contrast agent). Such contrast agents increase the absorption of X-rays and allow a better visibility of internal structures of model organisms (especially the various cavities, pores, etc.). In addition, the movement of tracers in selected timing experiments demonstrates some physiological functions of digestive and excretory system

  15. Pressure pulse induced-damage in live biological samples

    Science.gov (United States)

    Bo, C.; Balzer, J.; Godfrey, S.; Francois, M.; Saffell, J. L.; Rankin, S. M.; Proud, W. G.; Brown, K. A.

    2012-08-01

    Developing a cellular and molecular understanding of the nature of traumatic and post-traumatic effects of blast on live biological samples is critical for improving clinical outcomes. To analyze the effects of blast waves upon the cellular structures and the underlying physiological and biochemical changes, we have constructed an experimental platform capable of delivering compression waves, of amplitudes relevant to blast, to cell suspensions in a contained environment. Initial characterization of the system shows that cell cultures can be subjected to high-intensity compression waves up to 15 MPa in pressure and duration of 80 ± 10μs. Studies of mouse mesenchymal stem cells subjected to two different pressure impulses were analysed by cell counting, cell viability assays and microscopic evaluation: the experiments present evidence suggestive of increased levels of damage and loss of cellular integrity compared to uncompressed cell cultures.

  16. Digital holography microscopy in 3D biologic samples analysis

    Energy Technology Data Exchange (ETDEWEB)

    Ricardo, J O; Palacios, F; Palacios, G F; Sanchez, A [Department of Physics, University of Oriente (Cuba); Muramatsu, M [Department of General Physics, University of Sao Paulo - Sao Paulo (Brazil); Gesualdi, M [Engineering center, Models and Applied Social Science, UFABC - Sao Paulo (Brazil); Font, O [Department of Bio-ingeniering, University of Oriente - Santiago de Cuba (Cuba); Valin, J L [Mechanics Department, ISPJAE, Habana (Cuba); Escobedo, M; Herold, S [Department of Computation, University of Oriente (Cuba); Palacios, D F, E-mail: frpalaciosf@gmail.com [Department of Nuclear physics, University of Simon BolIva (Venezuela, Bolivarian Republic of)

    2011-01-01

    In this work it is used a setup for Digital Holography Microscopy (MHD) for 3D biologic samples reconstruction. The phase contrast image reconstruction is done by using the Double propagation Method. The system was calibrated and tested by using a micrometric scale and pure phase object respectively. It was simulated the human red blood cell (erythrocyte) and beginning from the simulated hologram the digital 3D phase image for erythrocytes it was calculated. Also there was obtained experimental holograms of human erythrocytes and its corresponding 3D phase images, being evident the correspondence qualitative and quantitative between these characteristics in the simulated erythrocyte and in the experimentally calculated by DHM in both cases.

  17. Digital holography microscopy in 3D biologic samples analysis

    International Nuclear Information System (INIS)

    In this work it is used a setup for Digital Holography Microscopy (MHD) for 3D biologic samples reconstruction. The phase contrast image reconstruction is done by using the Double propagation Method. The system was calibrated and tested by using a micrometric scale and pure phase object respectively. It was simulated the human red blood cell (erythrocyte) and beginning from the simulated hologram the digital 3D phase image for erythrocytes it was calculated. Also there was obtained experimental holograms of human erythrocytes and its corresponding 3D phase images, being evident the correspondence qualitative and quantitative between these characteristics in the simulated erythrocyte and in the experimentally calculated by DHM in both cases.

  18. Reflective interferometric chamber for quantitative phase imaging of biological sample dynamics

    OpenAIRE

    Shaked, Natan T.; Zhu, Yizheng; Badie, Nima; Bursac, Nenad; Wax, Adam

    2010-01-01

    We introduce a new interferometric setup for single-exposure wide-field holographic phase imaging of highly dynamic biological samples. In this setup, the interferometric signal originates from a specially designed reflective interferometric chamber (InCh), creating an off-axis interferogram on the output plane of the system. The setup only requires the InCh and a simple reflection-mode two lens imaging system, without the need for additional optical elements such as gratings in the beam path...

  19. Explaining Choice and Share of Category Requirements of Biologic Meat

    OpenAIRE

    Verhoef, Peter; Vlagsma-Brangule, Kristine

    2003-01-01

    textabstractIn this paper we examine factors determining choice and consumption of biologic or organic meat. In our model explaining choice and share of category requirements, we consider economic/marketing variables (quality, price, and distribution), emotions (fear, empathy, andguilt), social norms, environmental variables (environmental concern, green behavior, and perceived consumer effectiveness) as main antecedents of the choice and share of categoryrequirements of bio-meat. We also con...

  20. Microfluidic solutions enabling continuous processing and monitoring of biological samples: A review.

    Science.gov (United States)

    Karle, Marc; Vashist, Sandeep Kumar; Zengerle, Roland; von Stetten, Felix

    2016-07-27

    The last decade has witnessed tremendous advances in employing microfluidic solutions enabling Continuous Processing and Monitoring of Biological Samples (CPMBS), which is an essential requirement for the control of bio-processes. The microfluidic systems are superior to the traditional inline sensors due to their ability to implement complex analytical procedures, such as multi-step sample preparation, and enabling the online measurement of parameters. This manuscript provides a backgound review of microfluidic approaches employing laminar flow, hydrodynamic separation, acoustophoresis, electrophoresis, dielectrophoresis, magnetophoresis and segmented flow for the continuous processing and monitoring of biological samples. The principles, advantages and limitations of each microfluidic approach are described along with its potential applications. The challenges in the field and the future directions are also provided. PMID:27251944

  1. Transuranium analysis methodologies for biological and environmental samples

    International Nuclear Information System (INIS)

    Analytical procedures for the most abundant transuranium nuclides in the environment (i.e., plutonium and, to a lesser extent, americium) are available. There is a lack of procedures for doing sequential analysis for Np, Pu, Am, and Cm in environmental samples, primarily because of current emphasis on Pu and Am. Reprocessing requirements and waste disposal connected with the fuel cycle indicate that neptunium and curium must be considered in environmental radioactive assessments. Therefore it was necessary to develop procedures that determine all four of these radionuclides in the environment. The state of the art of transuranium analysis methodology as applied to environmental samples is discussed relative to different sample sources, such as soil, vegetation, air, water, and animals. Isotope-dilution analysis with 243Am (239Np) and 236Pu or 242Pu radionuclide tracers is used. Americium and curium are analyzed as a group, with 243Am as the tracer. Sequential extraction procedures employing bis(2-ethyl-hexyl)orthophosphoric acid (HDEHP) were found to result in lower yields and higher Am--Cm fractionation than ion-exchange methods

  2. Sampling requirements for forage quality characterization of rectangular hay bales

    Energy Technology Data Exchange (ETDEWEB)

    Sheaffer, C.C.; Martin, N.P.; Jewett, J.G.; Halgerson, J.; Moon, R.D.; Cuomo, G.R.

    2000-02-01

    Commercial lots of alfalfa (Medicago sativa L.) hay are often bought and sold on the basis of forage quality. Proper sampling is essential to obtain accurate forage quality results for pricing of alfalfa hay, but information about sampling is limited to small, 20- to 40-kg rectangular bales. Their objectives were to determine the within-bale variation in 400-kg rectangular bales and to determine the number and distribution of core samples required to represent the crude protein (CP), acid detergent fiber (ADF), neutral detergent fiber (NDF), and dry matter (DM) concentration in commercial lots of alfalfa hay. Four bales were selected from each of three hay lots and core sampled nine times per side for a total of 54 cores per bale. There was no consistent pattern of forage quality variation within bales. Averaged across lots, any portion of a bale was highly correlated with bale grand means for CP, ADF, NDF, and DM. Three lots of hay were probed six times per bale, one core per bale side from 55, 14, and 14 bales per lot. For determination of CP, ADF, NDF, and DM concentration, total core numbers required to achieve an acceptable standard error (SE) were minimized by sampling once per bale. Bootstrap analysis of data from the most variable hay lot suggested that forage quality of any lot of 400-kg alfalfa hay bales should be adequately represented by 12 bales sampled once per bale.

  3. Amchitka Island, Alaska, Biological Monitoring Report 2011 Sampling Results

    Energy Technology Data Exchange (ETDEWEB)

    None

    2013-09-01

    The Long-Term Surveillance and Maintenance (LTS&M) Plan for the U.S. Department of Energy (DOE) Office of Legacy Management (LM) Amchitka Island sites describes how LM plans to conduct its mission to protect human health and the environment at the three nuclear test sites located on Amchitka Island, Alaska. Amchitka Island, near the western end of the Aleutian Islands, is approximately 1,340 miles west-southwest of Anchorage, Alaska. Amchitka is part of the Aleutian Island Unit of the Alaska Maritime National Wildlife Refuge, which is administered by the U.S. Fish and Wildlife Service (USFWS). Since World War II, Amchitka has been used by multiple U.S. government agencies for various military and research activities. From 1943 to 1950, it was used as a forward air base for the U.S. Armed Forces. During the middle 1960s and early 1970s, the U.S. Department of Defense (DOD) and the U.S. Atomic Energy Commission (AEC) used a portion of the island as a site for underground nuclear tests. During the late 1980s and early 1990s, the U.S. Navy constructed and operated a radar station on the island. Three underground nuclear tests were conducted on Amchitka Island. DOD, in conjunction with AEC, conducted the first nuclear test (named Long Shot) in 1965 to provide data that would improve the United States' capability of detecting underground nuclear explosions. The second nuclear test (Milrow) was a weapons-related test conducted by AEC in 1969 as a means to study the feasibility of detonating a much larger device. Cannikin, the third nuclear test on Amchitka, was a weapons-related test detonated on November 6, 1971. With the exception of small concentrations of tritium detected in surface water shortly after the Long Shot test, radioactive fission products from the tests remain in the subsurface at each test location As a continuation of the environmental monitoring that has taken place on Amchitka Island since before 1965, LM in the summer of 2011 collected biological

  4. Amchitka Island, Alaska, Biological Monitoring Report 2011 Sampling Results

    International Nuclear Information System (INIS)

    The Long-Term Surveillance and Maintenance (LTS&M) Plan for the U.S. Department of Energy (DOE) Office of Legacy Management (LM) Amchitka Island sites describes how LM plans to conduct its mission to protect human health and the environment at the three nuclear test sites located on Amchitka Island, Alaska. Amchitka Island, near the western end of the Aleutian Islands, is approximately 1,340 miles west-southwest of Anchorage, Alaska. Amchitka is part of the Aleutian Island Unit of the Alaska Maritime National Wildlife Refuge, which is administered by the U.S. Fish and Wildlife Service (USFWS). Since World War II, Amchitka has been used by multiple U.S. government agencies for various military and research activities. From 1943 to 1950, it was used as a forward air base for the U.S. Armed Forces. During the middle 1960s and early 1970s, the U.S. Department of Defense (DOD) and the U.S. Atomic Energy Commission (AEC) used a portion of the island as a site for underground nuclear tests. During the late 1980s and early 1990s, the U.S. Navy constructed and operated a radar station on the island. Three underground nuclear tests were conducted on Amchitka Island. DOD, in conjunction with AEC, conducted the first nuclear test (named Long Shot) in 1965 to provide data that would improve the United States' capability of detecting underground nuclear explosions. The second nuclear test (Milrow) was a weapons-related test conducted by AEC in 1969 as a means to study the feasibility of detonating a much larger device. Cannikin, the third nuclear test on Amchitka, was a weapons-related test detonated on November 6, 1971. With the exception of small concentrations of tritium detected in surface water shortly after the Long Shot test, radioactive fission products from the tests remain in the subsurface at each test location As a continuation of the environmental monitoring that has taken place on Amchitka Island since before 1965, LM in the summer of 2011 collected biological and

  5. Hyperspectral imaging of nanoparticles in biological samples: Simultaneous visualization and elemental identification.

    Science.gov (United States)

    Peña, María Del Pilar Sosa; Gottipati, Abhishek; Tahiliani, Sahil; Neu-Baker, Nicole M; Frame, Mary D; Friedman, Adam J; Brenner, Sara A

    2016-05-01

    While engineered nanomaterials (ENMs) are increasingly incorporated into industrial processes and consumer products, the potential biological effects and health outcomes of exposure remain unknown. Novel advanced direct visualization techniques that require less time, cost, and resource investment than electron microscopy (EM) are needed for identifying and locating ENMs in biological samples. Hyperspectral imaging (HSI) combines spectrophotometry and imaging, using advanced optics and algorithms to capture a spectrum from 400 to 1000 nm at each pixel in an enhanced dark-field microscopic (EDFM) image. HSI-EDFM can be used to confirm the identity of the materials of interest in a sample and generate an image "mapping" their presence and location in a sample. Hyperspectral mapping is particularly important for biological samples, where ENM morphology is visually indistinct from surrounding tissue structures. While use of HSI (without mapping) is increasing, no studies to date have compared results from hyperspectral mapping with conventional methods. Thus, the objective of this study was to utilize EDFM-HSI to locate, identify, and map metal oxide ENMs in ex vivo histological porcine skin tissues, a toxicological model of cutaneous exposure, and compare findings with those of Raman spectroscopy (RS), energy-dispersive X-ray spectroscopy (EDS), and scanning electron microscopy (SEM). Results demonstrate that EDFM-HSI mapping is capable of locating and identifying ENMs in tissue, as confirmed by conventional methods. This study serves as initial confirmation of EDFM-HSI mapping as a novel and higher throughput technique for ENM identification in biological samples, and serves as the basis for further protocol development utilizing EDFM-HSI for semiquantitation of ENMs. Microsc. Res. Tech. 79:349-358, 2016. © 2016 Wiley Periodicals, Inc. PMID:26864497

  6. Determination of the sampling factor in biological standards using INAA and PIXE analysis

    International Nuclear Information System (INIS)

    Variations in the distribution of elemental concentrations in most biological materials suggest that a subsample, taken from a specimen containing the elements of interest, may not be representative of the specimen due to lack of homogeneity. It is therefore important when using a trace-element analysis technique, to know the representative mass, defined by a sampling factor for a given relative subsampling error, for whichever material is analysed and for each element detected. We have used two complementary techniques, instrumental neutron activation analysis (INAA) using short-lived radionuclides and proton-induced X-ray emission (PIXE) analysis to determine the concentration of 17 elements and obtain their sampling factors in a number of biological standards. In the case of PIXE a 2 MeV, 0.5 mm diameter proton beam was used and the sampling factor was expressed in terms of the number of spots on the target material required for a representative sample mass to be analysed. Six elements, Cl, Ca, Cu, K, Mn and Br, were detected by both techniques and results show that the values of the sampling factors are technique-dependent. (orig.)

  7. Biological samples positioning device for irradiations on a radial channel at the nuclear research reactor

    International Nuclear Information System (INIS)

    For the demand of an experimental device for biological samples positioning system for irradiations on a radial channel at the nuclear research reactor in operation was constructed and started up a device for the place and remove of the biological samples from the irradiation channels without interrupting the operation of the reactor. The economical valuations are effected comparing with another type of device with the same functions. This work formed part of an international project between Cuba and Brazil that undertook the study of the induced damages by various types of ionizing radiation in DNA molecules. Was experimentally tested the proposed solution, which demonstrates the practical validity of the device. As a result of the work, the experimental device for biological samples irradiations are installed and operating in the radial beam hole No3(BH3) for more than five years at the IEA-R1 Brazilian research reactor according to the solicited requirements the device. The designed device increases considerably the type of studies can be conducted in this reactor. Its practical application in research taking place in that facility, in the field of radiobiology and dosimetry, and so on is immediate

  8. Measurement of copper in biological samples by flame or electrothermal atomic absorption spectrometry.

    Science.gov (United States)

    Evenson, M A

    1988-01-01

    Guidelines presented here allow for copper analysis of biological materials by methods that are very sensitive, that require little sample preparation, that have few chemical or spectral interferences, that are inexpensive, and that require only usual care in contamination control. The commercial instruments for FAAS and ETAAS from Perkin-Elmer, from Varian, and from Instrumentation Laboratories Inc. (Allied Analytical Systems) all work well in either the flame or the flameless mode. Background correction techniques are not essential for copper analysis if care is taken with the sample preparation to minimize the background signals. Different types of burners will work adequately if one makes certain that the viscosity of the sample and the control products are similar to the calibration standards. Further, dilution of samples is preferred over increasing the viscosity of the calibration standards by the addition of a protein containing solution or a substance such as glycerol. A 1:10 dilution of blood plasma or serum with dilute nitric acid or water is all that is necessary for copper analysis by the FFAS methods. Cation and anion effects should be tested by bracketing the concentrations of the ions found in the sample with known amounts of ions in the sample solutions. Increasing the concentrations of the ions thought to interfere while keeping the copper concentration constant is another way to test for ion interferences.(ABSTRACT TRUNCATED AT 250 WORDS) PMID:3374386

  9. 9 CFR 113.3 - Sampling of biological products.

    Science.gov (United States)

    2010-01-01

    ... bacterial vaccines; (iii) Two samples of Coccidiosis Vaccine; (iv) Eighteen samples of Rabies Vaccine...) Twenty-two single-dose or 14 multiple-dose samples of Rabies Vaccine, Killed Virus; (viii) Sixteen single... be stated in the filed Outline of Production. (b) Unless otherwise prescribed by the...

  10. Entropic Sampling and Natural Selection in Biological Evolution

    OpenAIRE

    Choi, M. Y.; Lee, H. Y.; Kim, D.; Park, S H

    1996-01-01

    With a view to connecting random mutation on the molecular level to punctuated equilibrium behavior on the phenotype level, we propose a new model for biological evolution, which incorporates random mutation and natural selection. In this scheme the system evolves continuously into new configurations, yielding non-stationary behavior of the total fitness. Further, both the waiting time distribution of species and the avalanche size distribution display power-law behaviors with exponents close...

  11. Application of scanning electrochemical microscopy to biological samples

    OpenAIRE

    Lee, C.(Institute of Physics, Academia Sinica, Taipei, Taiwan); Kwak, J.; Bard, A J

    1990-01-01

    The scanning electrochemical microscope can be used in the feedback mode in two-dimensional scans over biological substrates to obtain topographic information at the micrometer level. In this mode, the effect of distance between a substrate (either conductive or insulating) and a scanning ultramicroelectrode tip on the electrolytic current flowing at the tip is recorded as a function of the tip x-y position. Scans of the upper surface of a grass leaf and the lower surface of a Ligustrum sinen...

  12. General guidelines for safe and expeditious international transport of samples subjected to biological dosimetry assessment

    International Nuclear Information System (INIS)

    It has been observed that victims of accidental overexposures show better chance of survival if they receive medical treatment early. The increased risk of scenarios involving mass casualties has stimulated the scientific community to develop tools that would help the medical doctors to treat victims. The biological dosimetry has become a routine test to estimate the dose, supplementing physical and clinical dosimetry. In case of radiation emergencies, in order to provide timely and effectively biological dosimetry assistance it is essential to guarantee an adequate transport of blood samples in principal, for providing support to countries that do not have bio-dosimetry laboratories. The objective of the present paper is to provide general guidelines, summarised in 10 points, for timely and proper receiving and sending of blood samples under National and International regulations, for safe and expeditious international transport. These guidelines cover the classification, packaging, marking, labelling, refrigeration and documentation requirements for the international shipping of blood samples and pellets, to provide assistance missions with a tool that would contribute with the preparedness for an effective bio-dosimetric response in cases of radiological or nuclear emergencies. (authors)

  13. The scope of detector Medipix2 in micro-radiography of biological samples

    Energy Technology Data Exchange (ETDEWEB)

    Dammer, J., E-mail: jiri.dammer@utef.cvut.cz [Institute of Experimental and Applied Physics, Czech Technical University in Prague, Horska 3a/22, CZ-12800 Prague 2 (Czech Republic); Weyda, F. [Biology Centre of the Academy of Sciences of the Czech Republic, Institute of Entomology, Branisovska 31, CZ-37005 Ceske Budejovice (Czech Republic); Faculty of Science, University of South Bohemia, Branisovska 31, CZ-37005 Ceske Budejovice (Czech Republic); Jakubek, J. [Institute of Experimental and Applied Physics, Czech Technical University in Prague, Horska 3a/22, CZ-12800 Prague 2 (Czech Republic); Skrabal, P. [Faculty of Biomedical Engineering, Czech Technical University in Prague, Nam. Sitna 3105, CZ-272 01 Kladno (Czech Republic); Sopko, V.; Vavrik, D. [Institute of Experimental and Applied Physics, Czech Technical University in Prague, Horska 3a/22, CZ-12800 Prague 2 (Czech Republic)

    2011-05-15

    We present our experimental setup devoted to high resolution X-ray micro-radiography that is suitable for imaging of small biological samples. The photon source is a FeinFocus micro-focus X-ray tube. The single photon counting pixel device Medipix2 serves as imaging area. Recently used imaging detectors as radiography films or scintillator detectors, cannot visualize required information about inner structure of scanned sample. Detectors Medipix2 do not suffer from so-called dark current noise and work in unlimited dynamic range. These features of detectors confer high quality and high contrast of final images. The radiographic imaging with detectors Medipix2 represents non-invasive and non-destructive method of investigation. Hereby, we demonstrate results of micro-radiographic study of internal structures of tiny biological samples. In addition to morphological and anatomical studies, we would like to present preliminary study of dynamic processes inside of organisms using micro-radiographic video-capturing.

  14. Analysis of biological slurry samples by total x-ray fluorescence after in situ microwave digestion

    International Nuclear Information System (INIS)

    Biological slurry samples were analyzed by total reflection x-ray fluorescence (TXRF) after an in situ microwave digestion procedure on the quartz reflector. This method lead to the removal of the matrix by the digestion and permits the enrichment of the analites by using sample amounts higher than those normally used in TXRF for the thin layer requirement since the organic matrix is removed. In consequence, the pre-concentration of sample is performed and the detection capability is increased by a quasi direct method. The samples analyzed were the international IAEA blood standard, the SRM bovine liver 1577-a standard and fresh onion tissues. Slurries were prepared in three ways: a.- weighing a sample amount on the reflector and adding suprapure nitric acid and internal standard followed by microwave digestion, b.-weighing a sample amount and water with an appropriate concentration of the internal standard in an Eppendorf vial, taking then an aliquot to the quartz reflector for microwave digestion with suprapure nitric acid, c.- weighing a sample amount of fresh tissue, homogenising with high speed homegenator to obtain a slurry sample which can be diluted in an ependorf vial with water an the internal standard. Then an aliquot is taken to the reflector for microwave digestion with suprapure nitric acid. Further details of sample preparation procedures will be discussed during presentation. The analysis was carried out in a Canberra spectrometer using the Kalpha lines of the Ag and Mo tubes. The elements Ca, K, Fe, Cu, Zn, Se, Mn, Rb, Br, Sr were determined. The effect of the preparation procedure was evaluated by the accuracy and precision of the results for each element and the percent of recovery. (author)

  15. Surface-enhanced Raman scattering detection of silver nanoparticles in environmental and biological samples.

    Science.gov (United States)

    Guo, Huiyuan; Xing, Baoshan; Hamlet, Leigh C; Chica, Andrea; He, Lili

    2016-06-01

    Growing concerns over the potential release and threat of silver nanoparticles (AgNPs) to environmental and biological systems urge researchers to investigate their fate and behavior. However, current analytical techniques cannot meet the requirements for rapidly, sensitively and reliably probing AgNPs in complex matrices. Surface-enhanced Raman spectroscopy (SERS) has shown great capability for rapid detection of AgNPs based on an indicator molecule that can bind on the AgNP surface. The objective of this study was to exploit SERS to detect AgNPs in environmental and biological samples through optimizing the Raman indicator for SERS. Seven indicator molecules were selected and determined to obtain their SERS signals at optimal concentrations. Among them, 1,2-di(4-pyridyl)ethylene (BPE), crystal violet and ferric dimethyl-dithiocarbamate (ferbam) produced the highest SERS intensities. Further experiments on binding competition between each two of the three candidates showed that ferbam had the highest AgNPs-binding ability. The underlying mechanism lies in the strong binding affinity of ferbam with AgNPs via multiple sulfur atoms. We further validated ferbam to be an effective indicator for SERS detection of as low as 0.1mg/L AgNPs in genuine surface water and 0.57 mg/L in spinach juice. Moreover, limited interference on SERS detection of AgNPs was found from environmentally relevant inorganic ions, organic matter, inorganic particles, as well as biologically relevant components, demonstrating the ferbam-assisted SERS is an effective and sensitive method to detect AgNPs in complex environmental and biological samples. PMID:26956173

  16. Elemental analysis of biological samples using deuteron induced X-rays and charged particles

    International Nuclear Information System (INIS)

    A method for elemental analysis in biological samples is presented. Samples were exposed to 4 MeV deuterons and both charged particle and X-ray spectra were recorded. The method was tested on a biopsi of mouseliver and a blood-serum-sample and was found promising for rapid analysis of samples associated with small amounts of material (μg). (Auth.)

  17. Application of scanning electrochemical microscopy to biological samples.

    Science.gov (United States)

    Lee, C; Kwak, J; Bard, A J

    1990-03-01

    The scanning electrochemical microscope can be used in the feedback mode in two-dimensional scans over biological substrates to obtain topographic information at the micrometer level. In this mode, the effect of distance between a substrate (either conductive or insulating) and a scanning ultramicroelectrode tip on the electrolytic current flowing at the tip is recorded as a function of the tip x-y position. Scans of the upper surface of a grass leaf and the lower surface of a Ligustrum sinensis leaf (which show open stomata structures) immersed in aqueous solution are shown. Scans of the upper surface of an elodea leaf in the dark and under irradiation, where the tip reaction is the reduction of oxygen produced by photosynthesis, demonstrate the possibility of obtaining information about the distribution of reaction sites on the substrate surface. PMID:2308933

  18. The use contrast agent for imaging biological samples

    Czech Academy of Sciences Publication Activity Database

    Dammer, J.; Weyda, František; Sopko, V.; Jakůbek, J.

    2011-01-01

    Roč. 6, C01096 (2011), s. 1-7. ISSN 1748-0221. [International Workshop on Radiation Imaging Detectors /12./. Cambridge, 11.07.2010-15.7.2010] R&D Projects: GA MŠk 2B06005 Grant ostatní: Research Program(CZ) 6840770029; Research Program(CZ) 6840770040; GA AV ČR(CZ) IAA600550614; GA MŠk(CZ) 2B06007; GA MŠk(CZ) 1PO4LA211; GA MŠk(CZ) LC06041 Institutional research plan: CEZ:AV0Z50070508 Keywords : x-ray radiography and digital radiography (DR) * x-ray detectors * inspections with x-rays Subject RIV: EA - Cell Biology Impact factor: 1.869, year: 2011

  19. Adaptive optics for deeper imaging of biological samples.

    Science.gov (United States)

    Girkin, John M; Poland, Simon; Wright, Amanda J

    2009-02-01

    Optical microscopy has been a cornerstone of life science investigations since its first practical application around 400 years ago with the goal being subcellular resolution, three-dimensional images, at depth, in living samples. Nonlinear microscopy brought this dream a step closer, but as one images more deeply the material through which you image can greatly distort the view. By using optical devices, originally developed for astronomy, whose optical properties can be changed in real time, active compensation for sample-induced aberrations is possible. Submicron resolution images are now routinely recorded from depths over 1mm into tissue. Such active optical elements can also be used to keep conventional microscopes, both confocal and widefield, in optimal alignment. PMID:19272766

  20. Soft Robotic Grippers for Biological Sampling on Deep Reefs

    Science.gov (United States)

    Galloway, Kevin C.; Becker, Kaitlyn P.; Phillips, Brennan; Kirby, Jordan; Licht, Stephen; Tchernov, Dan; Gruber, David F.

    2016-01-01

    Abstract This article presents the development of an underwater gripper that utilizes soft robotics technology to delicately manipulate and sample fragile species on the deep reef. Existing solutions for deep sea robotic manipulation have historically been driven by the oil industry, resulting in destructive interactions with undersea life. Soft material robotics relies on compliant materials that are inherently impedance matched to natural environments and to soft or fragile organisms. We demonstrate design principles for soft robot end effectors, bench-top characterization of their grasping performance, and conclude by describing in situ testing at mesophotic depths. The result is the first use of soft robotics in the deep sea for the nondestructive sampling of benthic fauna.

  1. Specific methods for theophylline assay in biological samples

    International Nuclear Information System (INIS)

    The objective of monitoring theophylline plasma levels in in therapeutic work is well established, and the consequences of using unspecific analytical methods are obvious. For the determination of pharmacokinetic parameters, concentrations far below the therapeutic range must often be measured. Interferences acceptable in therapeutic monitoring of theophylline could cause severe inaccuracy at these drug levels. The term specificity and its meaning are discussed in general and in relation to the different steps of the analytical procedure (e.g., sampling and sample work-up). Different analytical methods for theophylline are discussed in terms of specificity. Plasma concentrations of paraxanthine (1,7-dimethylxanthine) - a metabolite of caffeine - as high as 3 μg/ml have been observed, and the compound can interfere in various theophylline assay methods. An example is given of the pharmacokinetic consequences. (author)

  2. Use of STM for analysis of surfaces of biological samples

    Science.gov (United States)

    Permjakov, N. K.; Ananyan, M. A.; Luskinovich, P. N.; Sorokovoi, V. I.; Saveliev, S. V.

    1999-04-01

    Scanning tunnelling microscopy (STM) was used to image the cell surfaces of the olfactory organ of the shark Carcharhinus longimanus and ectoderm of the frog Xenopus laevis blastulae of 1024 stages, as well as human low-density lipoproteins surface. The samples from two of these objects were prepared by using traditional techniques for scanning electron microscopy (SEM). The lipoprotein samples were prepared by drying in the air. A comparison of the STM images with the earlier obtained SEM images indicates that there are some earlier unknown details of the surface structures of receptor microvilli and support cell membranes of the olfactory organ of the shark. There was found a fold of membrane on the surface of the ectodermal frog embryo cells, which covered yolk granules. STM images of the lipoprotein surface were obtained without increasing conductivity treatment.

  3. The models of experimental magnetic measurements of various biological samples

    International Nuclear Information System (INIS)

    Complete text of publication follows. At the Geomagnetic Institute, in the Laboratory for paleomagnetism and archeomagnetism research and at the Geomagnetic Observatory, Grocka (GCK) during the period from November 2004 to February 2008 the researchers carried out experimental magnetic measurements of the total-intensity gradient of the magnetic field vector (changes in the total magnetisation vector) of various biomaterials. Measurements of the gradient total intensity of the magnetic field vector were carried out by GSM-19 magnetometers of high accuracy and recording resolution (accuracy: ΔF=0.1 nT; sampling rate: 1-5 per second). During these experimental biomagnetic measurements samples of water, tissue, blood, cotton, wool, pitch and magnetite-powder were used. In this study, the part of the biomagnetic measurement results relate to the water, blood and tissue. The results of the measurements of gradient total-intensity of the magnetic field for the biomaterial samples showed physical processes which are connected with the diamagnetic and paramagnetic properties of such biomaterials.

  4. Evaluation of biological sample preparation for immunosignature-based diagnostics.

    Science.gov (United States)

    Chase, Brian Andrew; Johnston, Stephen Albert; Legutki, Joseph Barten

    2012-03-01

    To address the need for a universal system to assess health status, we previously described a method termed "immunosignaturing" which splays the entire humoral antibody repertoire across a peptide microarray. Two important issues relative to the potential broad use of immunosignatures are sample preparation and stability. In the present study, we compared the immunosignatures developed from serum, plasma, saliva, and antibodies eluted from blood dried onto filter paper. We found that serum and plasma provide identical immunosignatures. Immunosignatures derived from dried blood also correlated well with those from nondried serum from the same individual. Immunosignatures derived from dried blood were capable of distinguishing naïve mice from those infected with influenza virus. Saliva was applied to the arrays, and the IgA immunosignature correlated strongly with that from dried blood. Finally, we demonstrate that dried blood retains immunosignature information even when exposed to high temperature. This work expands the potential diagnostic uses for immunosignatures. These features suggest that different forms of archival samples can be used for diagnosis development and that in prospective studies samples can be easily procured. PMID:22237890

  5. Elemental distribution and sample integrity comparison of freeze-dried and frozen-hydrated biological tissue samples with nuclear microprobe

    International Nuclear Information System (INIS)

    The analysis of biological samples in frozen-hydrated state with micro-PIXE technique at Jožef Stefan Institute (JSI) nuclear microprobe has matured to a point that enables us to measure and examine frozen tissue samples routinely as a standard research method. Cryotome-cut slice of frozen-hydrated biological sample is mounted between two thin foils and positioned on the sample holder. The temperature of the cold stage in the measuring chamber is kept below 130 K throughout the insertion of the samples and the proton beam exposure. Matrix composition of frozen-hydrated tissue is consisted mostly of ice. Sample deterioration during proton beam exposure is monitored during the experiment, as both Elastic Backscattering Spectrometry (EBS) and Scanning Transmission Ion Microscopy (STIM) in on–off axis geometry are recorded together with the events in two PIXE detectors and backscattered ions from the chopper in a single list-mode file. The aim of this experiment was to determine differences and similarities between two kinds of biological sample preparation techniques for micro-PIXE analysis, namely freeze-drying and frozen-hydrated sample preparation in order to evaluate the improvements in the elemental localisation of the latter technique if any. In the presented work, a standard micro-PIXE configuration for tissue mapping at JSI was used with five detection systems operating in parallel, with proton beam cross section of 1.0 × 1.0 μm2 and a beam current of 100 pA. The comparison of the resulting elemental distributions measured at the biological tissue prepared in the frozen-hydrated and in the freeze-dried state revealed differences in elemental distribution of particular elements at the cellular level due to the morphology alteration in particular tissue compartments induced either by water removal in the lyophilisation process or by unsatisfactory preparation of samples for cutting and mounting during the shock-freezing phase of sample preparation

  6. Elemental distribution and sample integrity comparison of freeze-dried and frozen-hydrated biological tissue samples with nuclear microprobe

    Science.gov (United States)

    Vavpetič, P.; Vogel-Mikuš, K.; Jeromel, L.; Ogrinc Potočnik, N.; Pongrac, P.; Drobne, D.; Pipan Tkalec, Ž.; Novak, S.; Kos, M.; Koren, Š.; Regvar, M.; Pelicon, P.

    2015-04-01

    The analysis of biological samples in frozen-hydrated state with micro-PIXE technique at Jožef Stefan Institute (JSI) nuclear microprobe has matured to a point that enables us to measure and examine frozen tissue samples routinely as a standard research method. Cryotome-cut slice of frozen-hydrated biological sample is mounted between two thin foils and positioned on the sample holder. The temperature of the cold stage in the measuring chamber is kept below 130 K throughout the insertion of the samples and the proton beam exposure. Matrix composition of frozen-hydrated tissue is consisted mostly of ice. Sample deterioration during proton beam exposure is monitored during the experiment, as both Elastic Backscattering Spectrometry (EBS) and Scanning Transmission Ion Microscopy (STIM) in on-off axis geometry are recorded together with the events in two PIXE detectors and backscattered ions from the chopper in a single list-mode file. The aim of this experiment was to determine differences and similarities between two kinds of biological sample preparation techniques for micro-PIXE analysis, namely freeze-drying and frozen-hydrated sample preparation in order to evaluate the improvements in the elemental localisation of the latter technique if any. In the presented work, a standard micro-PIXE configuration for tissue mapping at JSI was used with five detection systems operating in parallel, with proton beam cross section of 1.0 × 1.0 μm2 and a beam current of 100 pA. The comparison of the resulting elemental distributions measured at the biological tissue prepared in the frozen-hydrated and in the freeze-dried state revealed differences in elemental distribution of particular elements at the cellular level due to the morphology alteration in particular tissue compartments induced either by water removal in the lyophilisation process or by unsatisfactory preparation of samples for cutting and mounting during the shock-freezing phase of sample preparation.

  7. Elemental distribution and sample integrity comparison of freeze-dried and frozen-hydrated biological tissue samples with nuclear microprobe

    Energy Technology Data Exchange (ETDEWEB)

    Vavpetič, P., E-mail: primoz.vavpetic@ijs.si [Jožef Stefan Institute, Jamova 39, SI-1000 Ljubljana (Slovenia); Vogel-Mikuš, K. [Biotechnical Faculty, Department of Biology, University of Ljubljana, Jamnikarjeva 101, SI-1000 Ljubljana (Slovenia); Jeromel, L. [Jožef Stefan Institute, Jamova 39, SI-1000 Ljubljana (Slovenia); Ogrinc Potočnik, N. [Jožef Stefan Institute, Jamova 39, SI-1000 Ljubljana (Slovenia); FOM-Institute AMOLF, Science Park 104, 1098 XG Amsterdam (Netherlands); Pongrac, P. [Biotechnical Faculty, Department of Biology, University of Ljubljana, Jamnikarjeva 101, SI-1000 Ljubljana (Slovenia); Department of Plant Physiology, University of Bayreuth, Universitätstr. 30, 95447 Bayreuth (Germany); Drobne, D.; Pipan Tkalec, Ž.; Novak, S.; Kos, M.; Koren, Š.; Regvar, M. [Biotechnical Faculty, Department of Biology, University of Ljubljana, Jamnikarjeva 101, SI-1000 Ljubljana (Slovenia); Pelicon, P. [Jožef Stefan Institute, Jamova 39, SI-1000 Ljubljana (Slovenia)

    2015-04-01

    The analysis of biological samples in frozen-hydrated state with micro-PIXE technique at Jožef Stefan Institute (JSI) nuclear microprobe has matured to a point that enables us to measure and examine frozen tissue samples routinely as a standard research method. Cryotome-cut slice of frozen-hydrated biological sample is mounted between two thin foils and positioned on the sample holder. The temperature of the cold stage in the measuring chamber is kept below 130 K throughout the insertion of the samples and the proton beam exposure. Matrix composition of frozen-hydrated tissue is consisted mostly of ice. Sample deterioration during proton beam exposure is monitored during the experiment, as both Elastic Backscattering Spectrometry (EBS) and Scanning Transmission Ion Microscopy (STIM) in on–off axis geometry are recorded together with the events in two PIXE detectors and backscattered ions from the chopper in a single list-mode file. The aim of this experiment was to determine differences and similarities between two kinds of biological sample preparation techniques for micro-PIXE analysis, namely freeze-drying and frozen-hydrated sample preparation in order to evaluate the improvements in the elemental localisation of the latter technique if any. In the presented work, a standard micro-PIXE configuration for tissue mapping at JSI was used with five detection systems operating in parallel, with proton beam cross section of 1.0 × 1.0 μm{sup 2} and a beam current of 100 pA. The comparison of the resulting elemental distributions measured at the biological tissue prepared in the frozen-hydrated and in the freeze-dried state revealed differences in elemental distribution of particular elements at the cellular level due to the morphology alteration in particular tissue compartments induced either by water removal in the lyophilisation process or by unsatisfactory preparation of samples for cutting and mounting during the shock-freezing phase of sample preparation.

  8. Determination of Alkali Ions in Biological and Environmental Samples.

    Science.gov (United States)

    Hauser, Peter C

    2016-01-01

    An overview of the common methods for the determination of the alkali metals is given. These are drawn from all of the three principle branches of quantitative analysis and consist mainly of optical atomic spectrometric methods, ion-selective electrodes, and the separation methods of ion-chromatography and capillary electrophoresis. Their main characteristics and performance parameters are discussed. Important specific applications are also examined, namely clinical analysis, single cell analysis, the analysis of soil samples and hydroponic nutrient solutions, as well as the detection of the radioactive (137)Cs isotope. PMID:26860298

  9. A comparison of quantitative reconstruction techniques for PIXE-tomography analysis applied to biological samples

    Energy Technology Data Exchange (ETDEWEB)

    Beasley, D.G., E-mail: dgbeasley@ctn.ist.utl.pt [IST/C2TN, Universidade de Lisboa, Campus Tecnológico e Nuclear, E.N.10, 2686-953 Sacavém (Portugal); Alves, L.C. [IST/C2TN, Universidade de Lisboa, Campus Tecnológico e Nuclear, E.N.10, 2686-953 Sacavém (Portugal); Barberet, Ph.; Bourret, S.; Devès, G.; Gordillo, N.; Michelet, C. [Univ. Bordeaux, CENBG, UMR 5797, F-33170 Gradignan (France); CNRS, IN2P3, CENBG, UMR 5797, F-33170 Gradignan (France); Le Trequesser, Q. [Univ. Bordeaux, CENBG, UMR 5797, F-33170 Gradignan (France); CNRS, IN2P3, CENBG, UMR 5797, F-33170 Gradignan (France); Institut de Chimie de la Matière Condensée de Bordeaux (ICMCB, UPR9048) CNRS, Université de Bordeaux, 87 avenue du Dr. A. Schweitzer, Pessac F-33608 (France); Marques, A.C. [IST/IPFN, Universidade de Lisboa, Campus Tecnológico e Nuclear, E.N.10, 2686-953 Sacavém (Portugal); Seznec, H. [Univ. Bordeaux, CENBG, UMR 5797, F-33170 Gradignan (France); CNRS, IN2P3, CENBG, UMR 5797, F-33170 Gradignan (France); Silva, R.C. da [IST/IPFN, Universidade de Lisboa, Campus Tecnológico e Nuclear, E.N.10, 2686-953 Sacavém (Portugal)

    2014-07-15

    The tomographic reconstruction of biological specimens requires robust algorithms, able to deal with low density contrast and low element concentrations. At the IST/ITN microprobe facility new GPU-accelerated reconstruction software, JPIXET, has been developed, which can significantly increase the speed of quantitative reconstruction of Proton Induced X-ray Emission Tomography (PIXE-T) data. It has a user-friendly graphical user interface for pre-processing, data analysis and reconstruction of PIXE-T and Scanning Transmission Ion Microscopy Tomography (STIM-T). The reconstruction of PIXE-T data is performed using either an algorithm based on a GPU-accelerated version of the Maximum Likelihood Expectation Maximisation (MLEM) method or a GPU-accelerated version of the Discrete Image Space Reconstruction Algorithm (DISRA) (Sakellariou (2001) [2]). The original DISRA, its accelerated version, and the MLEM algorithm, were compared for the reconstruction of a biological sample of Caenorhabditis elegans – a small worm. This sample was analysed at the microbeam line of the AIFIRA facility of CENBG, Bordeaux. A qualitative PIXE-T reconstruction was obtained using the CENBG software package TomoRebuild (Habchi et al. (2013) [6]). The effects of pre-processing and experimental conditions on the elemental concentrations are discussed.

  10. A comparison of quantitative reconstruction techniques for PIXE-tomography analysis applied to biological samples

    International Nuclear Information System (INIS)

    The tomographic reconstruction of biological specimens requires robust algorithms, able to deal with low density contrast and low element concentrations. At the IST/ITN microprobe facility new GPU-accelerated reconstruction software, JPIXET, has been developed, which can significantly increase the speed of quantitative reconstruction of Proton Induced X-ray Emission Tomography (PIXE-T) data. It has a user-friendly graphical user interface for pre-processing, data analysis and reconstruction of PIXE-T and Scanning Transmission Ion Microscopy Tomography (STIM-T). The reconstruction of PIXE-T data is performed using either an algorithm based on a GPU-accelerated version of the Maximum Likelihood Expectation Maximisation (MLEM) method or a GPU-accelerated version of the Discrete Image Space Reconstruction Algorithm (DISRA) (Sakellariou (2001) [2]). The original DISRA, its accelerated version, and the MLEM algorithm, were compared for the reconstruction of a biological sample of Caenorhabditis elegans – a small worm. This sample was analysed at the microbeam line of the AIFIRA facility of CENBG, Bordeaux. A qualitative PIXE-T reconstruction was obtained using the CENBG software package TomoRebuild (Habchi et al. (2013) [6]). The effects of pre-processing and experimental conditions on the elemental concentrations are discussed

  11. Biology and thermal requirements of Spodoptera cosmioides (Walk.) (Lepidoptera: Noctuidae)

    Energy Technology Data Exchange (ETDEWEB)

    Bavaresco, Alvimar [EPAGRI, Estacao Experimetal de Canoinhas, SC (Brazil)]. E-mail: alvimarbavaresco@bol.com.br; Garcia, Mauro S.; Gruetzmacher, Anderson D.; Foresti, Josemar; Ringenberg, Rudiney [Universidade Federal de Pelotas (UFPel), RS (Brazil). Dept. de Fitossanidade

    2002-01-15

    The biology of Spodoptera cosmioides (Walk.) was studied under different temperatures and its thermal requirements were determined, aiming to aid the rearing of this insect in the laboratory. Embryonic and post-embryonic periods were evaluated at seven different temperatures (14, 18, 22, 25, 28, 30 and 32 deg C) under environmental chamber conditions, with 14h photophase. The caterpillars were reared on an artificial diet containing white bean, soybean meal, yeast extract, wheat germ and powder milk as source of protein. The extent of the embryonic period decreased with the increase of temperature within the 14 deg C to 25 deg C temperature range, remaining constant between 28 deg C and 32 deg C. For the other phases (caterpillar, pre-pupa and pupa) an inverse relationship between temperature and duration was observed within the 14 deg C to 30 deg C temperature range, extending to 32 deg C for pupae. Duration of pupal phase for males was larger than for females resulting in asynchronous adult emergence. The temperature thresholds for the embryonic, larval, pre-pupal, pupal periods and total cycle were 9.34 deg C, 11.65 deg C, 9.65 deg C, 11.08 deg C and 11.23 deg C, with thermal constants of 62,73 degree-days (DD), 254.61DD, 33.42DD, 177.55DD and 525.11DD, respectively. Evaluating the pupal phase alone, the threshold temperatures were 11.25 deg C for males and 10.81deg C for females, with thermal constants of 188.26DD for males and 165.47DD for females. For total cycle, the threshold temperature and the thermal constant for males were 11.28 deg C and 535.85DD, whereas for females the same variables had values of 11.15 deg C and 513.17DD. So, the most adequate temperature for the development of S. cosmioides is within the range of 25 deg C and 28 deg C, where 9.6 to 11.7 generations of the insect can be annually obtained, in laboratory conditions. (author)

  12. Biology and thermal requirements of Spodoptera cosmioides (Walk.) (Lepidoptera: Noctuidae)

    International Nuclear Information System (INIS)

    The biology of Spodoptera cosmioides (Walk.) was studied under different temperatures and its thermal requirements were determined, aiming to aid the rearing of this insect in the laboratory. Embryonic and post-embryonic periods were evaluated at seven different temperatures (14, 18, 22, 25, 28, 30 and 32 deg C) under environmental chamber conditions, with 14h photophase. The caterpillars were reared on an artificial diet containing white bean, soybean meal, yeast extract, wheat germ and powder milk as source of protein. The extent of the embryonic period decreased with the increase of temperature within the 14 deg C to 25 deg C temperature range, remaining constant between 28 deg C and 32 deg C. For the other phases (caterpillar, pre-pupa and pupa) an inverse relationship between temperature and duration was observed within the 14 deg C to 30 deg C temperature range, extending to 32 deg C for pupae. Duration of pupal phase for males was larger than for females resulting in asynchronous adult emergence. The temperature thresholds for the embryonic, larval, pre-pupal, pupal periods and total cycle were 9.34 deg C, 11.65 deg C, 9.65 deg C, 11.08 deg C and 11.23 deg C, with thermal constants of 62,73 degree-days (DD), 254.61DD, 33.42DD, 177.55DD and 525.11DD, respectively. Evaluating the pupal phase alone, the threshold temperatures were 11.25 deg C for males and 10.81deg C for females, with thermal constants of 188.26DD for males and 165.47DD for females. For total cycle, the threshold temperature and the thermal constant for males were 11.28 deg C and 535.85DD, whereas for females the same variables had values of 11.15 deg C and 513.17DD. So, the most adequate temperature for the development of S. cosmioides is within the range of 25 deg C and 28 deg C, where 9.6 to 11.7 generations of the insect can be annually obtained, in laboratory conditions. (author)

  13. Robotic, MEMS-based Multi Utility Sample Preparation Instrument for ISS Biological Workstation Project

    Data.gov (United States)

    National Aeronautics and Space Administration — This project will develop a multi-functional, automated sample preparation instrument for biological wet-lab workstations on the ISS. The instrument is based on a...

  14. Detection of heavy metals in biological samples through anodic stripping voltammetry

    OpenAIRE

    Buzea, Vlad; Florescu, Monica; Badea, Mihaela

    2012-01-01

    The toxicological aspects due to the presence of heavy metals in biological samples impose to have accurate and rapid methods for their detection. This paper is aimed to review approaches to anodic stripping voltammetry (ASV) determination of several heavy metals (lead, cadmium, copper, mercury, zinc) in biological matrices (blood, urine, saliva, tissue sample). Analytical performances (LOD, data linearity range, sensitivity) of the reviewed methods were presented for several electrochemical ...

  15. speciation of selenium in human biological samples using online hyphenation of HPLC and ICP-MS

    International Nuclear Information System (INIS)

    compounds. Hyphenated method of HPLC and ICP-MS is also a powerful technique for selenoprotein separation in biological samples. For this purpose, size exclusive chromatography (SEC) is a competent alternative, Proteins can be eluted according to their molecular weights, and selenoproteins or Se-containing proteins can be implied by the corresponding elemental signals detected by the online-coupled ICP-MS. But for an immature technique, only the evidence of Se. existence can be found. More strictly optimized conditions for analysis still remain for further study at present. The characterization of selenoprotein needs more detailed analysis, such as by 2D electrophoresis, ESI-MS and so on. More improvement is still required for this coupling technique with the progress of the analysis science.

  16. The study on human health and environment by neutron activation analysis of biological samples

    International Nuclear Information System (INIS)

    - Choice of samples for the research goal and survey of individual food habit and sampling for the meaningful statistical output - Development of the optimum analytical method for the analysis of trace elements in biological samples such as hair, blood, and foods. - Quantitative analysis of several samples to identify the source of trace elements into human body. - Evaluation in view of health and environment to the trace elements in various sources which can be introduced inside human body

  17. Sample validity in biological trace element and organic nutrient research studies

    International Nuclear Information System (INIS)

    The state of the art of the biological trace element investigations is overviewed. Questions of biological validity, such as the influence of the 'status of sampling' of human subjects on the concentrations of selected elements are studied. Analytical validity problems, e.g. stability of Cd, Hg and Pb concentration in selected specimens, stability of selected organic nutrients in NBS SRMs, etc. are also discussed. Finally, it is concluded that the development of new biological reference materials should take into account the multidisciplinary demands of biological trace element investigations. (author) 20 refs.; 6 tables

  18. Determination of steroid hormones in biological and environmental samples using green microextraction techniques: an overview.

    Science.gov (United States)

    Aufartová, Jana; Mahugo-Santana, Cristina; Sosa-Ferrera, Zoraida; Santana-Rodríguez, José Juan; Nováková, Lucie; Solich, Petr

    2011-10-17

    Residues of steroid hormones have become a cause for concern because they can affect the biological activity of non-target organisms. Steroid hormones are a potential risk for wildlife and humans through the consumption of contaminated food or water. Their determination requires extraction and clean-up steps, prior to detection, to reach low concentration levels. In recent years, a great effort has been made to develop new analytical methodologies, such as microextraction techniques, that reduce environmental pollution. Researchers have modified old methods to incorporate procedures that use less-hazardous chemicals or that use smaller amounts of them. They are able to do direct analysis using miniaturised equipment and reduced amounts of solvents and wastes. These accomplishments are the main objectives of green analytical chemistry. In this overview, we focus on microextraction techniques for the determination of steroid hormones in biological (e.g., human urine, human serum, fish, shrimp and prawn tissue and milk) and environmental (e.g., wastewaters, surface waters, tap waters, river waters, sewage sludges, marine sediments and river sediments) samples. We comment on the most recent applications in sorptive-microextraction modes, such as solid phase microextraction (SPME) with molecularly imprinted polymers (MIPs), in-tube solid-phase microextraction (IT-SPME), stir-bar sorptive extraction (SBSE) and microextraction in packed sorbent (MEPS). We also describe liquid-phase microextraction (LPME) approaches reported in the literature that are applied to the determination of steroid hormones. PMID:21907019

  19. Identification of cadmium in biological samples using neutron activation analysis with radiochemistry separations

    International Nuclear Information System (INIS)

    Chile's 7500 km coastline of the Southern Pacific ocean, with about 4500 km of continental coastline that contains a variety of different geographical zones. This variety means that there is a great diversity of marine resources such as fish, shellfish and seaweeds. The utilization of these resources has been increasing in recent years making this sector an economically important one. The catch as of May 2002 came to 1.9 million tons and exports of the different species amounted to US$611.5 million as of April. But this important economic resource is being threatened by the technical demands imposed by importing countries, mainly the specific requirements for sanitary certification for fishery export products, depending on the markets of destination. The chemical element cadmium is one of the most strictly controlled elements due some shellfish accumulate a large amount of this element and to its high toxicity. The Chilean standard's analytical procedures for cadmium determination in hydro biological products, which must be met by laboratories that certify and control these products for export, are now being evaluated. Through its Chemical Metrology Unit, the Chilean Nuclear Energy Commission is strongly supporting this sector by preparing the secondary reference or control materials, and it has developed and implemented nuclear analytical methods for the certification of these materials, which will be used mostly in collaborative studies. This work describes the methodology developed for the determination of cadmium in biological samples, particularly in shellfish and fish (author)

  20. Absorbed dose measurements using TLDS in biological samples from beta radiation

    Directory of Open Access Journals (Sweden)

    José Eduardo Manzoli

    2006-01-01

    Full Text Available Irradiation of samples in peculiar experimental apparatus, subject to radiation spread, requires a special evaluation of absorbed dose implanted to the sample. Indirect calibration of the irradiation source, obtained in a different apparatus, and the spread, usually of very difficult theoretical evaluation, can cause very serious measurement errors, sometimes reaching 50%. In this work, the procedure for dose evaluation in an apparatus for beta irradiation of samples, usually biological ones,is presented, making use of calibration curves, obtained by irradiation in advance of thermoluminescent detectors in air, and so irradiating them in the same position of the sample. An application in blood sample irradiation is also presented.A irradiação de amostras em arranjos experimentais peculiares sujeitos a espalhamento necessita de uma determinação própria da dose absorvida que a amostra irá receber. A calibração indireta da fonte de irradiação, que ocorre em arranjo diferente, e o espalhamento, geralmente de difícil estimativa teórica, podem causar erros de medição muito elevados, não raro atingindo 50%. Neste trabalho é apresentado o procedimento para determinação da dose absorvida em um arranjo para irradiação beta de amostras, normalmente biológicas, utilizando curvas de calibração obtidas pela irradiação de dosímetros termoluminescentes no ar, e os irradiando na mesma posição das amostras. É apresentado um exemplo de aplicação para amostra irradiada de sangue.

  1. Large area synchrotron X-ray fluorescence mapping of biological samples

    International Nuclear Information System (INIS)

    Large area mapping of inorganic material in biological samples has suffered severely from prohibitively long acquisition times. With the advent of new detector technology we can now generate statistically relevant information for studying cell populations, inter-variability and bioinorganic chemistry in large specimen. We have been implementing ultrafast synchrotron-based XRF mapping afforded by the MAIA detector for large area mapping of biological material. For example, a 2.5 million pixel map can be acquired in 3 hours, compared to a typical synchrotron XRF set-up needing over 1 month of uninterrupted beamtime. Of particular focus to us is the fate of metals and nanoparticles in cells, 3D tissue models and animal tissues. The large area scanning has for the first time provided statistically significant information on sufficiently large numbers of cells to provide data on intercellular variability in uptake of nanoparticles. Techniques such as flow cytometry generally require analysis of thousands of cells for statistically meaningful comparison, due to the large degree of variability. Large area XRF now gives comparable information in a quantifiable manner. Furthermore, we can now image localised deposition of nanoparticles in tissues that would be highly improbable to 'find' by typical XRF imaging. In addition, the ultra fast nature also makes it viable to conduct 3D XRF tomography over large dimensions. This technology avails new opportunities in biomonitoring and understanding metal and nanoparticle fate ex-vivo. Following from this is extension to molecular imaging through specific anti-body targeted nanoparticles to label specific tissues and monitor cellular process or biological consequence

  2. Hybrid random walk-linear discriminant analysis method for unwrapping quantitative phase microscopy images of biological samples

    Science.gov (United States)

    Kim, Diane N. H.; Teitell, Michael A.; Reed, Jason; Zangle, Thomas A.

    2015-11-01

    Standard algorithms for phase unwrapping often fail for interferometric quantitative phase imaging (QPI) of biological samples due to the variable morphology of these samples and the requirement to image at low light intensities to avoid phototoxicity. We describe a new algorithm combining random walk-based image segmentation with linear discriminant analysis (LDA)-based feature detection, using assumptions about the morphology of biological samples to account for phase ambiguities when standard methods have failed. We present three versions of our method: first, a method for LDA image segmentation based on a manually compiled training dataset; second, a method using a random walker (RW) algorithm informed by the assumed properties of a biological phase image; and third, an algorithm which combines LDA-based edge detection with an efficient RW algorithm. We show that the combination of LDA plus the RW algorithm gives the best overall performance with little speed penalty compared to LDA alone, and that this algorithm can be further optimized using a genetic algorithm to yield superior performance for phase unwrapping of QPI data from biological samples.

  3. Determination of uranium in seawater, biological samples and sediments using laser induced fluorescence spectrometry

    International Nuclear Information System (INIS)

    Uranium has been determined in seawater, biological samples and sediments using laser induced fluorescence spectrometry (LIFS). The biological samples and sediments are digested with a mixture of HNO3, HClO4 and HF. The conductivity of the seawater should be below 5.0 mS and the pH of the sample should be in the range 6.5-9.0. The volume of the reagent used to enhance the fluorescence intensity was 0.5 ml. Comparison with other methods was favorable, LIFS being rapid, simple and sensitive, and well suited to environmental monitoring. (author)

  4. Large Scale Computing and Storage Requirements for Biological and Environmental Research

    Energy Technology Data Exchange (ETDEWEB)

    DOE Office of Science, Biological and Environmental Research Program Office (BER),

    2009-09-30

    In May 2009, NERSC, DOE's Office of Advanced Scientific Computing Research (ASCR), and DOE's Office of Biological and Environmental Research (BER) held a workshop to characterize HPC requirements for BER-funded research over the subsequent three to five years. The workshop revealed several key points, in addition to achieving its goal of collecting and characterizing computing requirements. Chief among them: scientific progress in BER-funded research is limited by current allocations of computational resources. Additionally, growth in mission-critical computing -- combined with new requirements for collaborative data manipulation and analysis -- will demand ever increasing computing, storage, network, visualization, reliability and service richness from NERSC. This report expands upon these key points and adds others. It also presents a number of"case studies" as significant representative samples of the needs of science teams within BER. Workshop participants were asked to codify their requirements in this"case study" format, summarizing their science goals, methods of solution, current and 3-5 year computing requirements, and special software and support needs. Participants were also asked to describe their strategy for computing in the highly parallel,"multi-core" environment that is expected to dominate HPC architectures over the next few years.

  5. Sample-size requirements for evaluating population size structure

    Science.gov (United States)

    Vokoun, J.C.; Rabeni, C.F.; Stanovick, J.S.

    2001-01-01

    A method with an accompanying computer program is described to estimate the number of individuals needed to construct a sample length-frequency with a given accuracy and precision. First, a reference length-frequency assumed to be accurate for a particular sampling gear and collection strategy was constructed. Bootstrap procedures created length-frequencies with increasing sample size that were randomly chosen from the reference data and then were compared with the reference length-frequency by calculating the mean squared difference. Outputs from two species collected with different gears and an artificial even length-frequency are used to describe the characteristics of the method. The relations between the number of individuals used to construct a length-frequency and the similarity to the reference length-frequency followed a negative exponential distribution and showed the importance of using 300-400 individuals whenever possible.

  6. Neutron beam preparation with Am-Be source for analysis of biological samples with PGNAA method

    International Nuclear Information System (INIS)

    Material analysis with prompt gamma neutron activation analysis (PGNAA) requires a proper geometrical arrangement for equipments in laboratory. Application of PGNAA in analysis of biological samples, due to small size of sample, needs attention to the dimension of neutron beam. In our work, neutron source has been made of 241Am-Be type. Activity of 241Am was 20 Ci which lead to neutron source strength of 4.4 x 107 neutrons per second. Water has been considered as the basic shielding material for the neutron source. The effect of various concentration of boric acid in the reduction of intensity of fast and thermal components of the neutron beam and gamma ray has been investigated. Gamma ray is produced by (α, n) reaction in Am-Be source (4.483 MeV), neutron capture by hydrogen (2.224 MeV), and neutron capture by boron (0.483 MeV). Various types of neutron and gamma ray dosimeters have been employed including BF3 and NE-213 detectors to detect fast and thermal neutrons. BGO scintillation detector has been used for gamma ray spectroscopy. It is shown that the gamma and neutron radiation dose due to direct beam is of the same magnitude as the dose due to radiation scattered in the laboratory ambient. It is concluded that 14 kg boric acid dissolved in 1,000 kg water is the optimum solution to surround the neutron source. The experimental results have been compared with Monte Carlo simulation. (author)

  7. Improved Butanol-Methanol (BUME) Method by Replacing Acetic Acid for Lipid Extraction of Biological Samples.

    Science.gov (United States)

    Cruz, Mutya; Wang, Miao; Frisch-Daiello, Jessica; Han, Xianlin

    2016-07-01

    Extraction of lipids from biological samples is a critical step in lipidomics, especially for shotgun lipidomics where lipid extracts are directly infused into a mass spectrometer. The butanol-methanol (BUME) extraction method was originally developed to extract lipids from plasma samples with 1 % acetic acid. Considering some lipids are sensitive to acidic environments, we modified this protocol by replacing acetic acid with lithium chloride solution and extended the modified extraction to tissue samples. Although no significant reduction of plasmalogen levels in the acidic BUME extracts of rat heart samples was found, the modified method was established to extract various tissue samples, including rat liver, heart, and plasma. Essentially identical profiles of the majority of lipid classes were obtained from the extracts of the modified BUME and traditional Bligh-Dyer methods. However, it was found that neither the original, nor the modified BUME method was suitable for 4-hydroxyalkenal species measurement in biological samples. PMID:27245345

  8. Recent advances in particle-induced X-ray emission analysis applied to biological samples

    International Nuclear Information System (INIS)

    Papers reporting the application of particle induced X-ray emission (PIXE) analysis to biological samples continue to appear regularly in the literature. The majority of these papers deal with blood, hair, and other common body organs while a few deal with biological samples from the environnment. A variety of sample preparation methods have been demonstrated, a number of which are improvements, refinements and extensions of the thick- and thin-sample preparation methods reported in the early development of PIXE. While many papers describe the development of PIXE techniques some papers are now describing applications of the methods to serious biological problems. The following two factors may help to stimulate more consistant use of the PIXE method. First, each PIXE facility should be organized to give rapid sample processing and should have available several sample preparation and handling methods. Second, those with the skill to use PIXE methods need to become closely associated with researches knowledge able in medical and biological sciences and they also need to become more involved in project planning and sample handling. (orig.)

  9. Membrane materials for storing biological samples intended for comparative nanotoxicological testing

    Science.gov (United States)

    Metelkin, A.; Kuznetsov, D.; Kolesnikov, E.; Chuprunov, K.; Kondakov, S.; Osipov, A.; Samsonova, J.

    2015-11-01

    The study is aimed at identifying the samples of most promising membrane materials for storing dry specimens of biological fluids (Dried Blood Spots, DBS technology). Existing sampling systems using cellulose fiber filter paper have a number of drawbacks such as uneven distribution of the sample spot, dependence of the spot spreading area on the individual biosample properties, incomplete washing-off of the sample due to partially inconvertible sorption of blood components on cellulose fibers, etc. Samples of membrane materials based on cellulose, polymers and glass fiber with applied biosamples were studied using methods of scanning electron microscopy, FT-IR spectroscopy and surface-wetting measurement. It was discovered that cellulose-based membrane materials sorb components of biological fluids inside their structure, while membranes based on glass fiber display almost no interaction with the samples and biological fluid components dry to films in the membrane pores between the structural fibers. This characteristic, together with the fact that membrane materials based on glass fiber possess sufficient strength, high wetting properties and good storage capacity, attests them as promising material for dry samples of biological fluids storage systems.

  10. Cadmium determination in biological samples using neutron activation analysis with radiochemical separations

    International Nuclear Information System (INIS)

    Chile has 7500 km of coastline on the Southern Pacific ocean,with about 4500 km of continental coastline that contains a variety of different geographical zones.This variety means that there is a great diversity of marine resources such as fish, shellfish and seaweeds. The utilization of these resources has been increasing in recent years making this sector an economically important one. The catch as of May 2002 came to 1.9 million tons and exports of the different species amounted to US$611.5 million as of April.But this important economic resource is being threatened by the technical demands imposed by importing countries, mainly the specific requirements for sanitary certification for fishery export products, depending on the markets of destination. The chemical element cadmium is one of the most strictly controlled elements due some shellfish accumulate a large amount of this element and to its high toxicity. The Chilean standard's analytical procedures for cadmium determination in hydro biological products, which must be met by laboratories that certify and control these products for export, are now being evaluated. Through its Chemical Metrology Unit, the Chilean Nuclear Energy Commission is strongly supporting this sector by preparing the secondary reference or control materials, and it has developed and implemented nuclear analytical methods for the certification of these materials, which will be used mostly in collaborative studies. This work describes the methodology developed for the determination of cadmium in biological samples, particularly in shellfish and fish. The method is based on neutron activation analysis with radiochemical separations, using the radioisotopes 115Cd and 115mIn, generated in the samples by bombarding with neutrons in a nuclear reactor. The samples were digested at 110oC with H2SO4 and H2O2 and then the radioactive cadmium element was separated from the other elements present in the samples using a Bio Rad AG 2-X8 resin

  11. Chemometric and Statistical Analyses of ToF-SIMS Spectra of Increasingly Complex Biological Samples

    Energy Technology Data Exchange (ETDEWEB)

    Berman, E S; Wu, L; Fortson, S L; Nelson, D O; Kulp, K S; Wu, K J

    2007-10-24

    Characterizing and classifying molecular variation within biological samples is critical for determining fundamental mechanisms of biological processes that will lead to new insights including improved disease understanding. Towards these ends, time-of-flight secondary ion mass spectrometry (ToF-SIMS) was used to examine increasingly complex samples of biological relevance, including monosaccharide isomers, pure proteins, complex protein mixtures, and mouse embryo tissues. The complex mass spectral data sets produced were analyzed using five common statistical and chemometric multivariate analysis techniques: principal component analysis (PCA), linear discriminant analysis (LDA), partial least squares discriminant analysis (PLSDA), soft independent modeling of class analogy (SIMCA), and decision tree analysis by recursive partitioning. PCA was found to be a valuable first step in multivariate analysis, providing insight both into the relative groupings of samples and into the molecular basis for those groupings. For the monosaccharides, pure proteins and protein mixture samples, all of LDA, PLSDA, and SIMCA were found to produce excellent classification given a sufficient number of compound variables calculated. For the mouse embryo tissues, however, SIMCA did not produce as accurate a classification. The decision tree analysis was found to be the least successful for all the data sets, providing neither as accurate a classification nor chemical insight for any of the tested samples. Based on these results we conclude that as the complexity of the sample increases, so must the sophistication of the multivariate technique used to classify the samples. PCA is a preferred first step for understanding ToF-SIMS data that can be followed by either LDA or PLSDA for effective classification analysis. This study demonstrates the strength of ToF-SIMS combined with multivariate statistical and chemometric techniques to classify increasingly complex biological samples

  12. Sample preparation strategies for food and biological samples prior to nanoparticle detection and imaging

    DEFF Research Database (Denmark)

    Larsen, Erik Huusfeldt; Löschner, Katrin

    2014-01-01

    Accurate and precise characterization of metrics such as size, mass, shape etc. of nanoparticles (NPs) remains a challenging task. In order to determine quantitative metrics that are relevant in food monitoring or in risk assessment, an instrumental separation method like asymmetric field flow...... AFFF-ICP-MS fractograms, which corresponded to the enzymatic digests, showed a major nano-peak (about 80 % recovery of AgNPs spiked to the meat) plus new smaller peaks that eluted close to the void volume of the fractograms. Small, but significant shifts in retention time of AFFF peaks were observed...... for the meat sample extracts and the corresponding neat AgNP suspension, and rendered sizing by way of calibration with AgNPs as sizing standards inaccurate. In order to gain further insight into the sizes of the separated AgNPs, or their possible dissolved state, fractions of the AFFF eluate were...

  13. The Free Energy Requirements of Biological Organisms; Implications for Evolution

    Science.gov (United States)

    Wolpert, David

    2016-04-01

    Recent advances in nonequilibrium statistical physics have provided unprecedented insight into the thermodynamics of dynamic processes. The author recently used these advances to extend Landauer's semi-formal reasoning concerning the thermodynamics of bit erasure, to derive the minimal free energy required to implement an arbitrary computation. Here I extend this analysis, deriving the minimal free energy required by an organism to run a given (stochastic) map $\\pi$ from its sensor inputs to its actuator outputs. I use this result to calculate the input-output map $\\pi$ of an organism that optimally trades off the free energy needed to run $\\pi$ with the phenotypic fitness that results from implementing $\\pi$. I end with general discussion of the limits imposed on the rate of the terrestrial biosphere's information processing by the flux of sunlight on the Earth.

  14. On the accuracy of protein determination in large biological samples by prompt gamma neutron activation analysis

    International Nuclear Information System (INIS)

    A prompt gamma neutron activation analysis (PGNAA) facility has been developed for the determination of nitrogen and thus total protein in large volume biological samples or the whole body of small animals. In the present work, the accuracy of nitrogen determination by PGNAA in phantoms of known composition as well as in four raw ground meat samples of about 1 kg mass was examined. Dumas combustion and Kjeldahl techniques were also used for the assessment of nitrogen concentration in the meat samples. No statistically significant differences were found between the concentrations assessed by the three techniques. The results of this work demonstrate the applicability of PGNAA for the assessment of total protein in biological samples of 0.25-1.5 kg mass, such as a meat sample or the body of small animal even in vivo with an equivalent radiation dose of about 40 mSv

  15. Presence of pesticide residues in water, sediment and biological samples taken from aquatic environments in Honduras

    International Nuclear Information System (INIS)

    The objective of this study was to detect the presence of persistent pesticides in water, sediment and biological samples taken from aquatic environments in Honduras during the period 1995-98. Additionally, the LC50 for 2 fungicides and 2 insecticides on post-larval Penaeus vannamei was determined in static water bioassays. A total of 80 water samples, 16 sediment samples and 7 biological samples (fish muscle tissue) were analyzed for detection of organochlorine and organophosphate pesticide residues. The results of sample analyses indicate a widespread contamination of Honduran continental and coastal waters with organochlorine pesticides. Most detections were of low (50 values and were therefore found to be much more toxic to the post-larval shrimp than the fungicides tridemorph and propiconazole. (author)

  16. Quantitation of vitamin B6 in biological samples by isotope dilution mass spectrometry

    International Nuclear Information System (INIS)

    Methods have been developed for the simultaneous quantitative analysis of vitamin B6 forms in biological samples by isotope dilution mass spectrometry using deuterated forms of pyridoxine, pyridoxal, pyridoxamine, and pyridoxic acid. The biological fluid or tissue sample was homogenized and then treated with a cocktail containing appropriate amounts of each deuterated vitamer, as well as the deuterated, phosphorylated vitamer forms. The individual vitamers were isolated from the homogenate by a complex high-performance liquid chromatographic procedure that provided separate fractions for each of the six vitamers found in biological samples. Aldehydic B6 vitamers were reduced to the alcohol form prior to acetylation and analysis by gas chromatography/mass spectrometry (GC/MS). The three resulting vitamers were analyzed by electron ionization GC/MS using a silicone capillary column. The methods have been applied to analysis of vitamin B6 in liver, milk, urine, and feces at levels as low as 0.02 nmol/ml

  17. A pre-treatment device designed for tritium analysis in biological samples

    International Nuclear Information System (INIS)

    Objective: To design a new pre-treatment device and to evaluate its efficiency in order to monitor the tritium levels in biological samples. Methods: The detection efficiency of tritium was determined with standard tritiated water. Recovery of tritiated water and organically bound tritium (OBT) were detected with high, medium and low activities of standard tritiated water and 3H-TdR (tritiated thymidine), respectively. Comparison of three kinds of biological samples using different pre-treatment devices was shown. Results: The standard curve can be used in environmental tritium measurement and the detection efficiency for tritium was 23.3%. When 40.0 g rice with standard HTO or 3H-TdR was pretreated with this device, the average recovery of HTO and OBT was about 95.4% , which showed good reproducibility.The comparison results were similar. Conclusions: The pre-treatment device can be used to survey the OBT in environmental biological samples. (authors)

  18. Quantitation of vitamin B6 in biological samples by isotope dilution mass spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Hachey, D.L.; Coburn, S.P.; Brown, L.T.; Erbelding, W.F.; DeMark, B.; Klein, P.D.

    1985-11-15

    Methods have been developed for the simultaneous quantitative analysis of vitamin B6 forms in biological samples by isotope dilution mass spectrometry using deuterated forms of pyridoxine, pyridoxal, pyridoxamine, and pyridoxic acid. The biological fluid or tissue sample was homogenized and then treated with a cocktail containing appropriate amounts of each deuterated vitamer, as well as the deuterated, phosphorylated vitamer forms. The individual vitamers were isolated from the homogenate by a complex high-performance liquid chromatographic procedure that provided separate fractions for each of the six vitamers found in biological samples. Aldehydic B6 vitamers were reduced to the alcohol form prior to acetylation and analysis by gas chromatography/mass spectrometry (GC/MS). The three resulting vitamers were analyzed by electron ionization GC/MS using a silicone capillary column. The methods have been applied to analysis of vitamin B6 in liver, milk, urine, and feces at levels as low as 0.02 nmol/ml.

  19. Energy-filtered transmission electron microscopy of biological samples on highly transparent carbon nanomembranes

    CERN Document Server

    Rhinow, Daniel; Weber, Nils-Eike; Beyer, André; Gölzhäuser, Armin; Kühlbrandt, Werner; Hampp, Norbert; Turchanin, Andrey; 10.1016/j.ultramic.2011.01.028

    2011-01-01

    Ultrathin carbon nanomembranes (CNM) comprising crosslinked biphenyl precursors have been tested as support films for energy-filtered transmission electron microscopy (EFTEM) of biological specimens. Due to their high transparency CNM are ideal substrates for electron energy loss spectroscopy (EELS) and electron spectroscopic imaging (ESI) of stained and unstained biological samples. Virtually background-free elemental maps of tobacco mosaic virus (TMV) and ferritin have been obtained from samples supported by ~ 1 nm thin CNM. Furthermore, we have tested conductive carbon nanomembranes (cCNM) comprising nanocrystalline graphene, obtained by thermal treatment of CNM, as supports for cryoEM of ice-embedded biological samples. We imaged ice-embedded TMV on cCNM and compared the results with images of ice-embedded TMV on conventional carbon film (CC), thus analyzing the gain in contrast for TMV on cCNM in a quantitative manner. In addition we have developed a method for the preparation of vitrified specimens, sus...

  20. Energy-filtered transmission electron microscopy of biological samples on highly transparent carbon nanomembranes

    International Nuclear Information System (INIS)

    Ultrathin carbon nanomembranes (CNM) comprising crosslinked biphenyl precursors have been tested as support films for energy-filtered transmission electron microscopy (EFTEM) of biological specimens. Due to their high transparency CNM are ideal substrates for electron energy loss spectroscopy (EELS) and electron spectroscopic imaging (ESI) of stained and unstained biological samples. Virtually background-free elemental maps of tobacco mosaic virus (TMV) and ferritin have been obtained from samples supported by ∼1 nm thin CNM. Furthermore, we have tested conductive carbon nanomembranes (cCNM) comprising nanocrystalline graphene, obtained by thermal treatment of CNM, as supports for cryoEM of ice-embedded biological samples. We imaged ice-embedded TMV on cCNM and compared the results with images of ice-embedded TMV on conventional carbon film (CC), thus analyzing the gain in contrast for TMV on cCNM in a quantitative manner. In addition we have developed a method for the preparation of vitrified specimens, suspended over the holes of a conventional holey carbon film, while backed by ultrathin cCNM. -- Research highlights: → We examine ultrathin carbon nanomembranes (CNM) as supports for biological TEM. → CNM comprise crosslinked biphenyl precursors. → CNM supports enable background-free elemental mapping of heavy and light elements. → We perform cryoEM of ice-embedded biological samples on graphene-like conductive CNM.

  1. Classification and Cluster Analysis of Complex Time-of-Flight Secondary Ion Mass Spectrometry for Biological Samples

    OpenAIRE

    Reichenbach, Stephen E; Tian, Xue; Tao, Qingping; Henderson, Alex

    2009-01-01

    Identifying and separating subtly different biological samples is one of the most critical tasks in biological analysis. Time-of-flight secondary ion mass spectrometry (ToF-SIMS) is becoming a popular and important technique in the analysis of biological samples, because it can detect molecular information and characterize chemical composition. ToF-SIMS spectra of biological samples are enormously complex with large mass ranges and many peaks. As a result the classification and cluster analys...

  2. 77 FR 13339 - Report on the Performance of Drug and Biologics Firms in Conducting Postmarketing Requirements...

    Science.gov (United States)

    2012-03-06

    ...Under the Food and Drug Administration Modernization Act of 1997 (Modernization Act), the Food and Drug Administration (FDA) is required to report annually in the Federal Register on the status of postmarketing requirements and commitments required of, or agreed upon by, holders of approved drug and biological products. This notice is the Agency's report on the status of the studies and......

  3. On multielement analysis of biological samples with the aid of neutron activation

    International Nuclear Information System (INIS)

    A main objective of this study was elucidation of problems of sampling and sample preparation methods for multielement analysis of environmental and biological specimens. Another was assessment of the potentials of multielement neutron activation analysis (NAA) in environmental and biological research. In an attempt to explain the great differences in the elemental concentration ranges between biopsy and autopsy samples as reported in the literature, it was shown that post mortem changes induce great variations in the apparent elemental composition of autopsy specimens resulting in serious systematic errors. Applications of NAA to analysis of tissues of experimental animals, human tissues in health and disease, and environmental samples are illustrated with several examples. The suitability of NAA for routine analysis of elements such as Cr, Mo and Se, which are difficult to determine by other methods has been specially discussed. (author)

  4. American College Biology and Zoology Course Requirements: A de facto Standardized Curriculum.

    Science.gov (United States)

    Heppner, Frank; And Others

    Without a formal mechanism to produce consensus, American colleges generally have come to agree on what constitutes an appropriate set of course requirements for Biology and Zoology majors. This report describes a survey of American four-year colleges and universities offering biology and/or zoology degrees. Questionnaires were sent to 741 biology…

  5. Molecularly Imprinted Solid-Phase Extraction and Liquid Chromatography for Biological Samples

    OpenAIRE

    Möller, Kristina

    2006-01-01

    This thesis focuses on the use of molecularly imprinted polymers as selective sorbents for solid-phase extraction (MISPE). The MISPE methods developed were mainly intended for use with biological samples, such as human urine and blood plasma. These body fluids are complex samples, which often need an effective clean-up step before analysis to reduce the levels of possible interfering substances from the matrix, especially if the analytes are present in trace amounts. Solid-phase extraction (S...

  6. Great Meteor East: an interim report on biological sampling and general relationship to physical oceanography

    International Nuclear Information System (INIS)

    The report deals with work carried out in June/July 1985 on RRS Discovery Cruise 156 to GME. The general physical oceanography of the area and the vertical distribution of chlorophyll a and nutrients are described. Primary production measurements and results are discussed in detail. Biological sampling of benthic and pelagic animals is described together with the subsequent laboratory treatment of the samples and some preliminary data on midwater biomass. (author)

  7. Total Integrated Sample Preparation for Microfluidic Immunoassays in Complex Biological Matrices

    OpenAIRE

    Apori, Akwasi Asare

    2011-01-01

    A high-throughput protein analysis platform with integrated sample preparation is developed to address the identified technology gaps in biomarker validation, clinical and point-of-care diagnostics. The goals of the technology are to automate and integrate protein sample preparation with electrokinetic separations, implement immunoassays capable of processing raw biological fluids, and perform high-throughput protein assays targeted for disease diagnosis.Integration of multiple functions is ...

  8. Determination of element concentrations in biological reference materials by solid sampling and other analytical methods

    Energy Technology Data Exchange (ETDEWEB)

    Schauenburg, H.; Weigert, P. (Bundesgesundheitsamt, Berlin (Germany). Centre for Surveillance and Health Evaluation of Environmental Chemicals (ZEBS))

    1992-04-01

    Using solid sampling with graphite furnace atomic absorption spectrometry (GFAAS), values for cadmium, copper, lead and zinc in six biological reference materials were obtained from up to four laboratories participating in three collaborative studies. These results are compared with those obtained with other methods used in routine analysis from laboratories of official food control. Under certain conditions solid sampling with GFAAS seems to be suitable for routine analysis as well as conventional methods. (orig.).

  9. Optimization of dielectrophoretic separation and concentration of pathogens in complex biological samples

    Science.gov (United States)

    Bisceglia, E.; Cubizolles, M.; Mallard, F.; Pineda, F.; Francais, O.; Le Pioufle, B.

    2013-05-01

    Sample preparation is a key issue of modern analytical methods for in vitro diagnostics of diseases with microbiological origins: methods to separate bacteria from other elements of the complex biological samples are of great importance. In the present study, we investigated the DEP force as a way to perform such a de-complexification of the sample by extracting micro-organisms from a complex biological sample under a highly non-uniform electric field in a micro-system based on an interdigitated electrodes array. Different parameters were investigated to optimize the capture efficiency, such as the size of the gap between the electrodes and the height of the capture channel. These parameters are decisive for the distribution of the electric field inside the separation chamber. To optimize these relevant parameters, we performed numerical simulations using COMSOL Multiphysics and correlated them with experimental results. The optimization of the capture efficiency of the device has first been tested on micro-organisms solution but was also investigated on human blood samples spiked with micro-organisms, thereby mimicking real biological samples.

  10. Integrated quantification and identification of aldehydes and ketones in biological samples

    NARCIS (Netherlands)

    Siegel, David; Meinema, Anne C; Permentier, Hjalmar; Hopfgartner, Gérard; Bischoff, Rainer

    2014-01-01

    The identification of unknown compounds remains to be a bottleneck of mass spectrometry (MS)-based metabolomics screening experiments. Here, we present a novel approach which facilitates the identification and quantification of analytes containing aldehyde and ketone groups in biological samples by

  11. A self-contained polymeric cartridge for automated biological sample preparationa

    OpenAIRE

    Xu, Guolin; Lee, Daniel Yoke San; Xie, Hong; Chiew, Deon; Hsieh, Tseng-Ming; Ali, Emril Mohamed; Lun Looi, Xing; Li, Mo-Huang; Ying, Jackie Y.

    2011-01-01

    Sample preparation is one of the most crucial processes for nucleic acids based disease diagnosis. Several steps are required for nucleic acids extraction, impurity washes, and DNA/RNA elution. Careful sample preparation is vital to the obtaining of reliable diagnosis, especially with low copies of pathogens and cells. This paper describes a low-cost, disposable lab cartridge for automatic sample preparation, which is capable of handling flexible sample volumes of 10 μl to 1 ml. This plastic ...

  12. Fast quantitative retardance imaging of biological samples using quadri-wave interferometry (Conference Presentation)

    Science.gov (United States)

    Aknoun, Sherazade; Bon, Pierre; Savatier, Julien; Monneret, Serge; Wattellier, Benoit F.

    2016-03-01

    We describe the use of polarized spatially coherent illumination to perform linear retardance imaging and measurements of semi-transparent biological samples using a quantitative phase imaging technique [1]. Quantitative phase imaging techniques [2-5] are used in microscopy for the imaging of semi-transparent samples and gives information about the optical path difference (OPD). The strength of those techniques is their non-invasive (the sample is not labelled) and fast approach. However, this high contrast is non-specific and cannot be linked to specific properties of the sample. To overcome this limitation, we propose to use polarized light in combination with QPI. Indeed, anisotropy has been used to reveal ordered fibrous structures in biological samples without any staining or labelling with polarized light microscopy [6-8]. Recent studies have shown polarimetry as a potential diagnostic tool for various dermatological diseases on thick tissue samples [9]. Particularly, specific collagen fibers spatial distribution has been demonstrated to be a signature for the optical diagnosis and prognosis of cancer in tissues [10]. In this paper, we describe a technical improvement of our technique based on high-resolution quadri-wave lateral shearing interferometry (QWLSI) and liquid crystal retarder to perform quantitative linear birefringence measurements on biological samples. The system combines a set of quantitative phase images with different excitation polarizations to create birefringence images. These give information about the local retardance and orientation of biological anisotropic components. We propose using a commercial QWLSI [11] (SID4Bio, Phasics SA, Saint Aubin, France) directly plugged onto a lateral video port of an inverted microscope (TE2000-U, Nikon, Japan). We are able to take retardance images in less than 1 second which allows us to record dynamic phenomena (living cells study) and make high speed acquisitions to reconstruct tissues virtual

  13. Technical assessment of compliance with work place air sampling requirements at T Plant. Revision No. 1

    International Nuclear Information System (INIS)

    The US DOE requires its contractors to conduct air sampling to detect and evaluate airborne radioactive material in the workplace. Hanford Reservation T Plant compliance with workplace air sampling requirements has been assessed. Requirements, basis for determining compliance and recommendations are included

  14. Quantitative and dynamic measurements of biological fresh samples with X-ray phase contrast tomography

    International Nuclear Information System (INIS)

    Quantitative measurements of biological fresh samples based on three-dimensional densitometry using X-ray phase contrast tomography are presented. X-ray phase contrast tomography using a Talbot grating interferometer was applied to biological fresh samples which were not fixed by any fixatives. To achieve a high-throughput measurement for the fresh samples the X-ray phase contrast tomography measurement procedure was improved. The three-dimensional structure of a fresh mouse fetus was clearly depicted as a mass density map using X-ray phase contrast tomography. The mouse fetus measured in the fresh state was then fixed by formalin and measured in the fixed state. The influence of the formalin fixation on soft tissue was quantitatively evaluated by comparing the fresh and fixed samples. X-ray phase contrast tomography was also applied to the dynamic measurement of a biological fresh sample. Morphological changes of a ring-shaped fresh pig aorta were measured tomographically under different degrees of stretching

  15. Quantitative and dynamic measurements of biological fresh samples with X-ray phase contrast tomography

    Energy Technology Data Exchange (ETDEWEB)

    Hoshino, Masato, E-mail: hoshino@spring8.or.jp; Uesugi, Kentaro [Japan Synchrotron Radiation Research Institute, 1-1-1 Kouto, Sayo, Hyogo 679-5198 (Japan); Tsukube, Takuro [Japanese Red Cross Kobe Hospital, 1-3-1 Wakinohamakaigandori, Chuo-ku, Kobe, Hyogo 651-0073 (Japan); Yagi, Naoto [Japan Synchrotron Radiation Research Institute, 1-1-1 Kouto, Sayo, Hyogo 679-5198 (Japan)

    2014-10-08

    Quantitative measurements of biological fresh samples based on three-dimensional densitometry using X-ray phase contrast tomography are presented. X-ray phase contrast tomography using a Talbot grating interferometer was applied to biological fresh samples which were not fixed by any fixatives. To achieve a high-throughput measurement for the fresh samples the X-ray phase contrast tomography measurement procedure was improved. The three-dimensional structure of a fresh mouse fetus was clearly depicted as a mass density map using X-ray phase contrast tomography. The mouse fetus measured in the fresh state was then fixed by formalin and measured in the fixed state. The influence of the formalin fixation on soft tissue was quantitatively evaluated by comparing the fresh and fixed samples. X-ray phase contrast tomography was also applied to the dynamic measurement of a biological fresh sample. Morphological changes of a ring-shaped fresh pig aorta were measured tomographically under different degrees of stretching.

  16. Electromembrane extraction as a rapid and selective miniaturized sample preparation technique for biological fluids

    DEFF Research Database (Denmark)

    Gjelstad, Astrid; Pedersen-Bjergaard, Stig; Seip, Knut Fredrik

    2015-01-01

    organic solvent, and into an aqueous receiver solution. The extraction is promoted by application of an electrical field, causing electrokinetic migration of the charged analytes. The method has shown to perform excellent clean-up and selectivity from complicated aqueous matrices like biological fluids......This special report discusses the sample preparation method electromembrane extraction, which was introduced in 2006 as a rapid and selective miniaturized extraction method. The extraction principle is based on isolation of charged analytes extracted from an aqueous sample, across a thin film of....... Technical aspects of electromembrane extraction, important extraction parameters as well as a handful of examples of applications from different biological samples and bioanalytical areas are discussed in the paper....

  17. Toward greener analytical techniques for the absolute quantification of peptides in pharmaceutical and biological samples.

    Science.gov (United States)

    Van Eeckhaut, Ann; Mangelings, Debby

    2015-09-10

    Peptide-based biopharmaceuticals represent one of the fastest growing classes of new drug molecules. New reaction types included in the synthesis strategies to reduce the rapid metabolism of peptides, along with the availability of new formulation and delivery technologies, resulted in an increased marketing of peptide drug products. In this regard, the development of analytical methods for quantification of peptides in pharmaceutical and biological samples is of utmost importance. From the sample preparation step to their analysis by means of chromatographic or electrophoretic methods, many difficulties should be tackled to analyze them. Recent developments in analytical techniques emphasize more and more on the use of green analytical techniques. This review will discuss the progresses in and challenges observed during green analytical method development for the quantification of peptides in pharmaceutical and biological samples. PMID:25864956

  18. Simultaneous determination of arsenic and selenium in biological samples by HG-AFS

    Energy Technology Data Exchange (ETDEWEB)

    Sun, Hanwen; Liu, Zhanfeng; Shi, Hongmei [Hebei University, College of Chemistry and Environmental Science, Baoding (China); Wu, Wenjuan [Third Hospital of Hebei Medical University, Department of Radiology, Shijiazhuang 050051 (China); Li, Liqing [Hebei University, College of Chemistry and Environmental Science, Baoding (China); Taishan College, Department of Chemistry, Shan Dong Taian (China)

    2005-06-01

    A new method is proposed for simultaneous determination of traces of arsenic (As) and selenium (Se) in biological samples by hydride-generation double-channel non-dispersive atomic-fluorescence spectrometry (HG-AFS) from tartaric acid media. The effects of analytical conditions on fluorescence signal intensity were investigated and optimized. Interferences from coexisting ions were evaluated. Under optimum conditions linear response ranges above 20 {mu}g L{sup -1} for As and 32 {mu}g L{sup -1} for Se were obtained with detection limits of 0.13 and 0.12 {mu}g L{sup -1}, respectively. The precision for elevenfold determination of As at the 4 {mu}g L{sup -1} level and of Se at the 8 {mu}g L{sup -1} level were 2.7 and 1.9% (RSD), respectively. Recoveries of 92.5-95.5% for As and 101.2-108.4% for Se were obtained for four biological samples and two certified biological reference materials. The proposed method has the advantages of simple operation, high sensitivity, and high efficiency; it was successfully used for simultaneous determination of As and Se in biological samples. (orig.)

  19. Inductively coupled plasma mass spectrometry in the analysis of biological samples and pharmaceutical drugs

    Science.gov (United States)

    Ossipov, K.; Seregina, I. F.; Bolshov, M. A.

    2016-04-01

    Inductively coupled plasma mass spectrometry (ICP-MS) is widely used in the analysis of biological samples (whole blood, serum, blood plasma, urine, tissues, etc.) and pharmaceutical drugs. The shortcomings of this method related to spectral and non-spectral interferences are manifested in full measure in determination of the target analytes in these complex samples strongly differing in composition. The spectral interferences are caused by similarity of masses of the target component and sample matrix components. Non-spectral interferences are related to the influence of sample matrix components on the physicochemical processes taking place during formation and transportation of liquid sample aerosols into the plasma, on the value and spatial distribution of plasma temperature and on the transmission of the ion beam from the interface to mass spectrometer detector. The review is devoted to analysis of different mechanisms of appearance of non-spectral interferences and to ways for their minimization or elimination. Special attention is paid to the techniques of biological sample preparation, which largely determine the mechanisms of the influence of sample composition on the results of element determination. The ways of lowering non-spectral interferences by instrumental parameter tuning and application of internal standards are considered. The bibliography includes 189 references.

  20. Will Women Diagnosed with Breast Cancer Provide Biological Samples for Research Purposes?

    Directory of Open Access Journals (Sweden)

    Shelley A Harris

    Full Text Available Little is known about the response rates for biological sample donation and attitudes towards control recruitment, especially in younger women. The goals of this pilot study were to determine in women recently diagnosed with breast cancer, the proportion of cases willing to provide biological samples and for purposes of control recruitment, contact information for friends or colleagues.A population-based sample of breast cancer cases (n = 417, 25-74 years was recruited from the Ontario Cancer Registry in 2010 and self-administered questionnaires were completed to determine willingness to provide samples (spot or 24-hr urine, saliva, blood and contact information for friends/colleagues for control recruitment. Using Χ2 analyses of contingency tables we evaluated if these proportions varied by age group (<45 and 45+ and other factors such as ethnicity, education, income, body mass index (BMI, smoking status and alcohol consumption.Cases were willing to provide blood samples, by visiting a clinic (62% or by having a nurse visit the home (61%. Moreover, they would provide saliva (73%, and morning or 24-hr urine samples (66% and 52%. Younger cases (≤45 were 3 times (OR more likely more than older cases to agree to collect morning urine (95% CI: 1.15-8.35. Only 26% of cases indicated they would provide contact information of friends or work colleagues to act as controls. Educated cases were more likely to agree to provide samples, and cases who consumed alcohol were more willing to provide contact information. Ethnicity, income, BMI and smoking had little effect on response rates.Reasonable response rates for biological sample collection should be expected in future case controls studies in younger women, but other methods of control selection must be devised.

  1. Methods for collection and analysis of aquatic biological and microbiological samples

    Science.gov (United States)

    Britton, L.J.; Greeson, P.E.

    1988-01-01

    Chapter A4, methods for collection and analyses of aquatic biological and microbiological samples, contains methods used by the U.S. Geological Survey to collect, preserve, and analyze waters to determine their biological and microbiological properties. Part 1 consists of detailed descriptions of more than 45 individual methods, including those for bacteria, phytoplankton, zooplankton, seston, periphyton, macrophytes, benthic invertebrates, fish and other vertebrates, cellular contents, productivity and bioassay. Each method is summarized, and the applications, interferences, apparatus, reagents, analyses, calculations, reporting of results, precisions, and references are given. Part 2 consists of a glossary. Part 3 is a list of taxonomic references. (USGS)

  2. A supplement to "Methods for collection and analysis of aquatic biological and microbiological samples"

    Science.gov (United States)

    1979-01-01

    The report contains methods used by the U.S. Geological Survey to collect, preserve, and analyze waters to determine their biological and microbiological properties. It supplements, "Methods for Collection and Analysis of Aquatic Biological and Microbiological Samples" (TWRI, Book 5, Chapter A4, 1977, edited by P. E. Greeson, T. A. Ehlke, G. A. Irwin, B. W. Lium, and K. V. Slack). Included in the supplement are 5 new methods, a new section of selected taxonomic references for Ostracoda, and 6 revised methods.

  3. Robust identification of noncoding RNA from transcriptomes requires phylogenetically-informed sampling.

    Directory of Open Access Journals (Sweden)

    Stinus Lindgreen

    2014-10-01

    Full Text Available Noncoding RNAs are integral to a wide range of biological processes, including translation, gene regulation, host-pathogen interactions and environmental sensing. While genomics is now a mature field, our capacity to identify noncoding RNA elements in bacterial and archaeal genomes is hampered by the difficulty of de novo identification. The emergence of new technologies for characterizing transcriptome outputs, notably RNA-seq, are improving noncoding RNA identification and expression quantification. However, a major challenge is to robustly distinguish functional outputs from transcriptional noise. To establish whether annotation of existing transcriptome data has effectively captured all functional outputs, we analysed over 400 publicly available RNA-seq datasets spanning 37 different Archaea and Bacteria. Using comparative tools, we identify close to a thousand highly-expressed candidate noncoding RNAs. However, our analyses reveal that capacity to identify noncoding RNA outputs is strongly dependent on phylogenetic sampling. Surprisingly, and in stark contrast to protein-coding genes, the phylogenetic window for effective use of comparative methods is perversely narrow: aggregating public datasets only produced one phylogenetic cluster where these tools could be used to robustly separate unannotated noncoding RNAs from a null hypothesis of transcriptional noise. Our results show that for the full potential of transcriptomics data to be realized, a change in experimental design is paramount: effective transcriptomics requires phylogeny-aware sampling.

  4. Constructing Database for Drugs and its Application to Biological Sample by HPTLC and GC/MS

    Energy Technology Data Exchange (ETDEWEB)

    Yoo, Y.C.; Park, S.W.; Lim, M.A.; Baeck, S.K.; Park, S.Y.; Lee, J.S.; Lee, J.S. [National Institute of Scientific investigation, Seoul (Korea); Lho, D.S. [Korea Institute of Science and Technology, Seoul (Korea)

    2000-04-01

    For the identification of unknown drugs in biological samples, we attempted rapid high performance thin layer chromatographic method which is sensitive and selective chromatographic analysis of high performance thin layer chromatography (HPTLC) with automated TLC sampler and ultra-violet (UV) scanner. We constructed HPTLC database (DB) on two hundred five drugs by using the data of Rf values and UV spectra (scan 200-360 nm) as well as gas chromatography/mass spectrometry (GC/MS) DB on ninety six drugs by using the data of relative retention time (RRT) on lidocain and mass spectra. After extracting drugs in geological sample by solid phase extraction (Clean Screen ZSDAU020), we applied them to HPTLC and GC/MS DB. Drugs, especially extracted from biological samples, showed good matching ratio to HPTLC DB and these drugs were confirmed by GC/MS. In conclusion, this DB system is thought to be very useful method for the screening of unknown drugs in biological samples. (author). 9 refs., 2 tabs., 6 figs.

  5. Analysis of parallel optical sampling rate and ADC requirements in digital coherent receivers

    DEFF Research Database (Denmark)

    Lorences Riesgo, Abel; Galili, Michael; Peucheret, Christophe

    2012-01-01

    We comprehensively assess analog-to-digital converter requirements in coherent digital receiver schemes with parallel optical sampling. We determine the electronic requirements in accordance with the properties of the free running local oscillator.......We comprehensively assess analog-to-digital converter requirements in coherent digital receiver schemes with parallel optical sampling. We determine the electronic requirements in accordance with the properties of the free running local oscillator....

  6. Electroanalytical Determination of Danofloxacin in Biological Samples Using Square Wave Voltammetry

    Directory of Open Access Journals (Sweden)

    Chirley Vanessa Boone

    2014-10-01

    Full Text Available The voltammetric behavior of danofloxacin (DFX has been studied, in aqueous solution, on a glassy carbon electrode using square wave voltammetry (SWV as electroanalytical technique. After optimization of the experimental conditions, DFX was analyzed in spiked biologic samples using a Britton-Robinson buffer with pH = 5.0 as the supporting electrolyte. Oxidation occurs at 0.98 V vs. Ag/AgCl in a two-electron process controlled by adsorption of the electrogenerated products on the electrode surface. A acceptable recovery was obtained for assay of spiked biologic samples, with value of 98.7% for the swine urine and 95.3 % for the bovine urine.

  7. Estimate of beta and gamma contamination in vegetable and animal biologic samples using GM detectors

    International Nuclear Information System (INIS)

    The paper presents the use of a large area Geiger-Mueller Detector (GMD) with aluminium window of 50 mm thickness (3,4 mg/cm2) in a measuring chain in order to estimate the beta and gamma contamination of biologic samples. The technical data for GMD are: - window area for gamma radiation: 300 cm2; - grid transmission: 80%; - operating voltage: 1100 - 1300 V; - minimum detectable beta energy: 125 keV; - dead time: 250 ms; - background (shielded with 100 mm Pb + 1 mm Cu): 6 pulses/s; - service life: 5 x 108 counts. Using this GMD together with a set of large area beta standard sources and a set of point gamma sources we could estimate beta and gamma contamination in the energy range 125 keV - 2.5 MeV for biologic samples. (authors)

  8. Correction of radiation absorption on biological samples using Rayleigh to Compton scattering ratio

    Science.gov (United States)

    Pereira, Marcelo O.; Conti, Claudio de Carvalho; dos Anjos, Marcelino J.; Lopes, Ricardo T.

    2012-06-01

    The aim of this work was to develop a method to correct the absorbed radiation (the mass attenuation coefficient curve) in low energy (E gamma-ray source of 241Am (59.54 keV) also applied to certified biological samples of milk powder, hay powder and bovine liver (NIST 1557B). In addition, six methods of effective atomic number determination were used as described in literature to determinate the Rayleigh to Compton scattering ratio (R/C), in order to calculate the mass attenuation coefficient. The results obtained by the proposed method were compared with those obtained using the transmission method. The experimental results were in good agreement with transmission values suggesting that the method to correct radiation absorption presented in this paper is adequate for biological samples.

  9. Radioisotope Sample Measurement Techniques in Medicine and Biology. Proceedings of the Symposium on Radioisotope Sample Measurement Techniques

    International Nuclear Information System (INIS)

    The medical and biological applications of radioisotopes depend on two basically different types of measurements, those on living subjects in vivo and those on samples in vitro. The International Atomic Energy Agency has in the past held several meetings on in vivo measurement techniques, notably whole-body counting and radioisotope scanning. The present volume contains the Proceedings of the first Symposium the Agency has organized to discuss the various aspects of techniques for sample measurement in vitro. The range of these sample measurement techniques is very wide. The sample may weigh a few milligrams or several hundred grams, and may be in the gaseous, liquid or solid state. Its radioactive content may consist of a single, known radioisotope or several unknown ones. The concentration of radioactivity may be low, medium or high. The measurements may be made manually or automatically and any one of the many radiation detectors now available may be used. The 53 papers presented at the Symposium illustrate the great variety of methods now in use for radioactive- sample measurements. The first topic discussed is gamma-ray spectrometry, which finds an increasing number of applications in sample measurements. Other sections of the Proceedings deal with: the use of computers in gamma-ray spectrometry and multiple tracer techniques; recent developments in activation analysis where both gamma-ray spectrometry and computing techniques are applied; thin-layer and paper radio chromatographic techniques for use with low energy beta-ray emitters; various aspects of liquid scintillation counting techniques in the measurement of alpha- and beta-ray emitters, including chemical and colour quenching; autoradiographic techniques; calibration of equipment; and standardization of radioisotopes. Finally, some applications of solid-state detectors are presented; this section may be regarded as a preview of important future developments. The meeting was attended by 203 participants

  10. Specific determination of clinical and toxicological important substances in biological samples by LC-MS

    International Nuclear Information System (INIS)

    This thesis of this dissertation is the specific determination of clinical and toxicological important substances in biological samples by LC-MS. Nicotine was determined in serum after application of nicotine plaster and nicotine nasal spray with HPLC-ESI-MS. Cotinine was determined direct in urine with HPLC-ESI-MS. Short time anesthetics were determined in blood and cytostatics were determined in liquor with HPLC-ESI-MS. (botek)

  11. Assessment of the differential linear coherent scattering coefficient of biological samples

    International Nuclear Information System (INIS)

    New differential linear coherent scattering coefficient, μCS, data for four biological tissue types (fat pork, tendon chicken, adipose and fibroglandular human breast tissues) covering a large momentum transfer interval (0.07≤q≤70.5 nm-1), resulted from combining WAXS and SAXS data, are presented in order to emphasize the need to update the default data-base by including the molecular interference and the large-scale arrangements effect. The results showed that the differential linear coherent scattering coefficient demonstrates influence of the large-scale arrangement, mainly due to collagen fibrils for tendon chicken and fibroglandular breast samples, and triacylglycerides for fat pork and adipose breast samples at low momentum transfer region. While, at high momentum transfer, the μCS reflects effects of molecular interference related to water for tendon chicken and fibroglandular samples and, fatty acids for fat pork and adipose samples.

  12. Correction of radiation absorption on biological samples using Rayleigh to Compton scattering ratio

    Energy Technology Data Exchange (ETDEWEB)

    Pereira, Marcelo O., E-mail: marcelocefetrj@gmail.com [Nuclear Instrumentation Laboratory, PEN/COPPE/UFRJ, Rio de Janeiro (Brazil); Basic Disciplines Department, CEFET-RJ Uned Nova Iguacu, Rio de Janeiro (Brazil); Conti, Claudio de Carvalho [Radiation Protection and Dosimetry Institute, CNEN/IRD, Rio de Janeiro (Brazil); Anjos, Marcelino J. dos [Nuclear Instrumentation Laboratory, PEN/COPPE/UFRJ, Rio de Janeiro (Brazil); Physics Institute, State University of Rio de Janeiro, Rio de Janeiro (Brazil); Lopes, Ricardo T. [Nuclear Instrumentation Laboratory, PEN/COPPE/UFRJ, Rio de Janeiro (Brazil)

    2012-06-01

    The aim of this work was to develop a method to correct the absorbed radiation (the mass attenuation coefficient curve) in low energy (E < 30 keV) applied to a biological matrix based on the Rayleigh to Compton scattering ratio and the effective atomic number. For calibration, scattering measurements were performed on standard samples of radiation produced by a gamma-ray source of {sup 241}Am (59.54 keV) also applied to certified biological samples of milk powder, hay powder and bovine liver (NIST 1557B). In addition, six methods of effective atomic number determination were used as described in literature to determinate the Rayleigh to Compton scattering ratio (R/C), in order to calculate the mass attenuation coefficient. The results obtained by the proposed method were compared with those obtained using the transmission method. The experimental results were in good agreement with transmission values suggesting that the method to correct radiation absorption presented in this paper is adequate for biological samples.

  13. Application of Compton suppression spectrometry in the improvement of nuclear analytical techniques for biological samples

    International Nuclear Information System (INIS)

    Compton Suppression Factors (SF) and Compton Reduction Factors (RF) of the UT Austin's Compton suppression spectrometer being parameters characterizing the system performance were measured using ''1''3''7Cs and ''6''0Co point sources. The system performance was evaluated as a function of energy and geometry. The (P/C), A(P/C), (P/T), Cp, and Ce were obtained for each of the parameters. The natural background reduction factor in the anticoincidence mode and that of normal mode was calculated and its effect on the detection limit of biological samples evaluated. Applicability of the spectrometer and the method for biological samples was tested in the measurement of twenty-four elements (Ba, Sr, I, Br, Cu, V, Mg, Na, Cl, Mn, Ca, Sn, In, K, Mo, Cd, Zn, As, Sb, Ni, Rb, Cs, Fe, and Co) commonly found in food, milk, tea and tobacco items. They were determined from seven National Institute for Standard and Technology (NIST) certified reference materials (rice flour, oyster tissue, non-fat powdered milk, peach leaves, tomato leaves, apple leaves, and citrus leaves). Our results shows good agreement with the NIST certified values, indicating that the method developed in the present study is suitable for the determination of aforementioned elements in biological samples without undue interference problems

  14. Sampling designs matching species biology produce accurate and affordable abundance indices

    Directory of Open Access Journals (Sweden)

    Grant Harris

    2013-12-01

    Full Text Available Wildlife biologists often use grid-based designs to sample animals and generate abundance estimates. Although sampling in grids is theoretically sound, in application, the method can be logistically difficult and expensive when sampling elusive species inhabiting extensive areas. These factors make it challenging to sample animals and meet the statistical assumption of all individuals having an equal probability of capture. Violating this assumption biases results. Does an alternative exist? Perhaps by sampling only where resources attract animals (i.e., targeted sampling, it would provide accurate abundance estimates more efficiently and affordably. However, biases from this approach would also arise if individuals have an unequal probability of capture, especially if some failed to visit the sampling area. Since most biological programs are resource limited, and acquiring abundance data drives many conservation and management applications, it becomes imperative to identify economical and informative sampling designs. Therefore, we evaluated abundance estimates generated from grid and targeted sampling designs using simulations based on geographic positioning system (GPS data from 42 Alaskan brown bears (Ursus arctos. Migratory salmon drew brown bears from the wider landscape, concentrating them at anadromous streams. This provided a scenario for testing the targeted approach. Grid and targeted sampling varied by trap amount, location (traps placed randomly, systematically or by expert opinion, and traps stationary or moved between capture sessions. We began by identifying when to sample, and if bears had equal probability of capture. We compared abundance estimates against seven criteria: bias, precision, accuracy, effort, plus encounter rates, and probabilities of capture and recapture. One grid (49 km2 cells and one targeted configuration provided the most accurate results. Both placed traps by expert opinion and moved traps between capture

  15. Sampling designs matching species biology produce accurate and affordable abundance indices

    Science.gov (United States)

    Farley, Sean; Russell, Gareth J.; Butler, Matthew J.; Selinger, Jeff

    2013-01-01

    Wildlife biologists often use grid-based designs to sample animals and generate abundance estimates. Although sampling in grids is theoretically sound, in application, the method can be logistically difficult and expensive when sampling elusive species inhabiting extensive areas. These factors make it challenging to sample animals and meet the statistical assumption of all individuals having an equal probability of capture. Violating this assumption biases results. Does an alternative exist? Perhaps by sampling only where resources attract animals (i.e., targeted sampling), it would provide accurate abundance estimates more efficiently and affordably. However, biases from this approach would also arise if individuals have an unequal probability of capture, especially if some failed to visit the sampling area. Since most biological programs are resource limited, and acquiring abundance data drives many conservation and management applications, it becomes imperative to identify economical and informative sampling designs. Therefore, we evaluated abundance estimates generated from grid and targeted sampling designs using simulations based on geographic positioning system (GPS) data from 42 Alaskan brown bears (Ursus arctos). Migratory salmon drew brown bears from the wider landscape, concentrating them at anadromous streams. This provided a scenario for testing the targeted approach. Grid and targeted sampling varied by trap amount, location (traps placed randomly, systematically or by expert opinion), and traps stationary or moved between capture sessions. We began by identifying when to sample, and if bears had equal probability of capture. We compared abundance estimates against seven criteria: bias, precision, accuracy, effort, plus encounter rates, and probabilities of capture and recapture. One grid (49 km2 cells) and one targeted configuration provided the most accurate results. Both placed traps by expert opinion and moved traps between capture sessions, which

  16. Sampling and Analysis Instruction for the Demolition of the Masonry Block for the 108-F Biological Laboratory

    International Nuclear Information System (INIS)

    This sampling and analysis instruction (SAI) has been prepared to clearly define the sampling and analysis activities to be performed in support of the demolition and disposition (or disposal) of the 108-F Biological Laboratory masonry block walls

  17. Standards in biological dosimetry: A requirement to perform an appropriate dose assessment.

    Science.gov (United States)

    Voisin, Philippe

    2015-11-01

    Every year, many countries perform a significant number of investigations based on biological radiation dose assessment to check suspected or true overexposure by irradiation of radiation workers and individuals of the general population. The scoring of dicentrics in peripheral blood lymphocytes has gradually become the "gold standard" for the biodosimetry-based assessment of accidental situations. Nevertheless, other "classical" biodosimetric methods such as micronuclei, prematurely condensed chromosomes (PCC) and FISH translocations are relevant in some exposure situations, also for surveillance of groups of populations at risk. Historical international intercomparison studies have shown discrepancies among dose-effect curves used to estimate doses from blood samples irradiated between 0 and 4Gy. Recent experimental work performed by the biological dosimetry laboratory of the French Institute for Radiation Protection and Nuclear Safety (IRSN) has shown the impact of some blood harvesting parameters on the mitotic index, and consequently on the quality of dose assessment. Therefore, it was relevant to define the best Quality Assurance (QA) and Quality Control (QC) criteria to harmonize protocols among biodosimetry laboratories. Complementary with several editions of an IAEA technical manual, ISO standards were written with the view of considering the most used chromosome aberrations assays: dicentrics and micronuclei. An important feature of these standards is to address the organization of population triage and laboratories networking that would be required in case of a large nuclear event or malicious act involving radioactive material. These ISO standards are relevant and helpful to implement a coordinated response of several biodosimetry networks in Europe, Japan, Canada, and to support European programs such as MULTIBIODOSE and RENEB. A new important ISO standard on the use of FISH translocations in retrospective dosimetry is now being drafted. PMID:26520381

  18. Preconcentration and determination of heavy metals in water, sediment and biological samples

    Directory of Open Access Journals (Sweden)

    Shirkhanloo Hamid

    2011-01-01

    Full Text Available In this study, a simple, sensitive and accurate column preconcentration method was developed for the determination of Cd, Cu and Pb ions in river water, urine and sediment samples by flame atomic absorption spectrometry. The procedure is based on the retention of the analytes on a mixed cellulose ester membrane (MCEM column from buffered sample solutions and then their elution from the column with nitric acid. Several parameters, such as pH of the sample solution, volume of the sample and eluent and flow rates of the sample were evaluated. The effects of diverse ions on the preconcentration were also investigated. The recoveries were >95 %. The developed method was applied to the determination of trace metal ions in river water, urine and sediment samples, with satisfactory results. The 3δ detection limits for Cu, Pb and Cd were found to be 2, 3 and 0.2 μg dm−3, respectively. The presented procedure was successfully applied for determination of the copper, lead and cadmium contents in real samples, i.e., river water and biological samples.

  19. Sample Size Requirements for Structural Equation Models: An Evaluation of Power, Bias, and Solution Propriety

    Science.gov (United States)

    Wolf, Erika J.; Harrington, Kelly M.; Clark, Shaunna L.; Miller, Mark W.

    2013-01-01

    Determining sample size requirements for structural equation modeling (SEM) is a challenge often faced by investigators, peer reviewers, and grant writers. Recent years have seen a large increase in SEMs in the behavioral science literature, but consideration of sample size requirements for applied SEMs often relies on outdated rules-of-thumb.…

  20. Critique of Hanford Waste Vitrification Plant off-gas sampling requirements

    International Nuclear Information System (INIS)

    Off-gas sampling and monitoring activities needed to support operations safety, process control, waste form qualification, and environmental protection requirements of the Hanford Waste Vitrification Plant (HWVP) have been evaluated. The locations of necessary sampling sites have been identified on the basis of plant requirements, and the applicability of Defense Waste Processing Facility (DWPF) reference sampling equipment to these HWVP requirements has been assessed for all sampling sites. Equipment deficiencies, if present, have been described and the bases for modifications and/or alternative approaches have been developed

  1. Biological rhythms, metabolic syndrome and current depressive episode in a community sample.

    Science.gov (United States)

    Moreira, Fernanda Pedrotti; Jansen, Karen; Mondin, Thaíse Campos; Cardoso, Taiane de Azevedo; Magalhães, Pedro Vieira da Silva; Kapczinski, Flavio; Frey, Benicio N; Oses, Jean Pierre; Souza, Luciano Dias de Mattos; da Silva, Ricardo Azevedo; Wiener, Carolina David

    2016-10-01

    The purpose of this study was to assess the disruption in biological rhythms and metabolic syndrome (MetS) in individuals with depressive episode. This was a cross-sectional, population-based study with a representative sample of 905 young adults. Current depressive episode were confirmed by a psychologist using the Mini International Neuropsychiatric Interview (MINI)-Plus. Self-reported biological rhythms were assessed using the Biological Rhythms Interview of Assessment in Neuropsychiatry (BRIAN). MetS was defined using modified NCEP/ATPIII criteria. Significant main effects of current depressive episode (p<0.001, η(2)=0.163) and MetS (p=0.001, η(2)=0.011) were observed on total BRIAN score. There was a significant interaction between depression and MetS in total biological rhythm scores (p=0.002, η(2)=0.011) as well as sleep (p=0.001, η(2)=0.016) and social domains (p<0.001, η(2)=0.014). In the depressive group, subjects with MetS had a higher disruption in total BRIAN scores (p=0.010), sleep domain (p=0.004), social domain (p=0.005) and in the eating pattern domain approached the level of significance (p=0.098), when compared to subjects with no MetS. The results of the present study showed that self-reported disruptions in biological rhythms are associated with key components of the MetS in community adults with MDD. The understanding of the complex interactions between biological rhythms, MetS and depression are important in the development of preventive and therapeutic strategies. PMID:27343724

  2. 40 CFR 80.1348 - What gasoline sample retention requirements apply to refiners and importers?

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 16 2010-07-01 2010-07-01 false What gasoline sample retention... PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) REGULATION OF FUELS AND FUEL ADDITIVES Gasoline Benzene Sampling, Testing and Retention Requirements § 80.1348 What gasoline sample retention...

  3. Direct Observation of Wet Biological Samples by Graphene Liquid Cell Transmission Electron Microscopy.

    Science.gov (United States)

    Park, Jungwon; Park, Hyesung; Ercius, Peter; Pegoraro, Adrian F; Xu, Chen; Kim, Jin Woong; Han, Sang Hoon; Weitz, David A

    2015-07-01

    Recent development of liquid phase transmission electron microscopy (TEM) enables the study of specimens in wet ambient conditions within a liquid cell; however, direct structural observation of biological samples in their native solution using TEM is challenging since low-mass biomaterials embedded in a thick liquid layer of the host cell demonstrate low contrast. Furthermore, the integrity of delicate wet samples is easily compromised during typical sample preparation and TEM imaging. To overcome these limitations, we introduce a graphene liquid cell (GLC) using multilayer graphene sheets to reliably encapsulate and preserve biological samples in a liquid for TEM observation. We achieve nanometer scale spatial resolution with high contrast using low-dose TEM at room temperature, and we use the GLC to directly observe the structure of influenza viruses in their native buffer solution at room temperature. The GLC is further extended to investigate whole cells in wet conditions using TEM. We also demonstrate the potential of the GLC for correlative studies by TEM and fluorescence light microscopy imaging. PMID:26065925

  4. Evaluation of a gas chromatography method for azelaic acid determination in selected biological samples

    Directory of Open Access Journals (Sweden)

    Mahdi Garelnabi

    2010-09-01

    Full Text Available Background: Azelaic acid (AzA is the best known dicarboxilic acid to have pharmaceutical benefits and clinical applications and also to be associated with some diseases pathophysiology. Materials and Methods: We extracted and methylesterified AzA and determined its concentration in human plasma obtained from healthy individuals and also in mice fed AzA containing diet for three months. Results: AzA was detected in Gas Chromatography (GC and confirmed by Liquid chromatography mass spectrometry (LCMS, and gas chromatography mass spectrometry (GCMC. Our results have shown that AzA can be determined efficiently in selected biological samples by GC method with 1nM limit of detection (LoD and the limit of quantification (LoQ; was established at 50nM. Analytical Sensitivity as assayed by hexane demonstrated an analytical sensitivity at 0.050nM. The method has demonstrated 8-10% CV batch repeatability across the sample types and 13-18.9% CV for the Within-Lab Precision analysis. The method has shown that AzA can efficiently be recovered from various sample preparation including liver tissue homogenate (95% and human plasma (97%. Conclusions: Because of its simplicity and lower limit of quantification, the present method provides a useful tool for determining AzA in various biological sample preparations.

  5. Offer of rapid testing and alternative biological samples as practical tools to implement HIV screening programs.

    Science.gov (United States)

    Parisi, Maria Rita; Soldini, Laura; Di Perri, Giovanni; Tiberi, Simon; Lazzarin, Adriano; Lillo, Flavia B

    2009-10-01

    Implementation of HIV testing has the objective to increase screening, identify and counsel persons with infection, link them to clinical services and reduce transmission. Rapid tests and/or alternative biological samples (like oral fluid) give the option for a better general consent in approaching screening, immediate referral of HIV positives to medical treatment and partner notification. We tested the performance characteristics of an oral fluid-based rapid HIV test (Rapidtest HIV lateral flow-Healthchem diag. LLC) in comparison with routinely utilized methods in a selected population of known positive (N = 121) or negative (N = 754) subjects. The sensitivity of the rapid test was 99.1% (one false negative sample) and the specificity 98.8%. Five negatives showed a faint reactivity, 3 of these were reactive also in the reference test, one with a p24 only reaction in Western blot. If these 3 samples were excluded from the analysis the specificity increases to 99.2%. Results from our study confirm that, although a continuous improvement of the test performance is still needed to minimize false negative and positive results, rapid test and alternative biological samples may contribute to HIV prevention strategies by reaching a larger population particularly when and where regular screening procedures are difficult to obtain. PMID:20128446

  6. Demonstration Exercise of a Validated Sample Collection Method for Powders Suspected of Being Biological Agents in Georgia 2006

    International Nuclear Information System (INIS)

    August 7, 2006 the state of Georgia conducted a collaborative sampling exercise between the Georgia National Guard 4th Civil Support Team Weapons of Mass Destruction (CST-WMD) and the Georgia Department of Human Resources Division of Public Health demonstrating a recently validated bulk powder sampling method. The exercise was hosted at the Federal Law Enforcement Training Center (FLETC) at Glynn County, Georgia and involved the participation of the Georgia Emergency Management Agency (GEMA), Georgia National Guard, Georgia Public Health Laboratories, the Federal Bureau of Investigation Atlanta Office, Georgia Coastal Health District, and the Glynn County Fire Department. The purpose of the exercise was to demonstrate a recently validated national sampling standard developed by the American Standards and Test Measures (ASTM) International; ASTM E2458 Standard Practice for Bulk Sample Collection and Swab Sample Collection of Visible Powders Suspected of Being Biological Agents from Nonporous Surfaces. The intent of the exercise was not to endorse the sampling method, but to develop a model for exercising new sampling methods in the context of existing standard operating procedures (SOPs) while strengthening operational relationships between response teams and analytical laboratories. The exercise required a sampling team to respond real-time to an incident cross state involving a clandestine bio-terrorism production lab found within a recreational vehicle (RV). Sample targets consisted of non-viable gamma irradiated B. anthracis Sterne spores prepared by Dugway Proving Ground. Various spore concentration levels were collected by the ASTM method, followed by on- and off-scene analysis utilizing the Center for Disease Control (CDC) Laboratory Response Network (LRN) and National Guard Bureau (NGB) CST mobile Analytical Laboratory Suite (ALS) protocols. Analytical results were compared and detailed surveys of participant evaluation comments were examined. I will present

  7. Mapping molecular orientational distributions for biological sample in 3D (Conference Presentation)

    Science.gov (United States)

    HE, Wei; Ferrand, Patrick; Richter, Benjamin; Bastmeyer, Martin; Brasselet, Sophie

    2016-04-01

    Measuring molecular orientation properties is very appealing for scientists in molecular and cell biology, as well as biomedical research. Orientational organization at the molecular scale is indeed an important brick to cells and tissues morphology, mechanics, functions and pathologies. Recent work has shown that polarized fluorescence imaging, based on excitation polarization tuning in the sample plane, is able to probe molecular orientational order in biological samples; however this applies only to information in 2D, projected in the sample plane. To surpass this limitation, we extended this approach to excitation polarization tuning in 3D. The principle is based on the decomposition of any arbitrary 3D linear excitation in a polarization along the longitudinal z-axis, and a polarization in the transverse xy-sample plane. We designed an interferometer with one arm generating radial polarization light (thus producing longitudinal polarization under high numerical aperture focusing), the other arm controlling a linear polarization in the transverse plane. The amplitude ratio between the two arms can vary so as to get any linear polarized excitation in 3D at the focus of a high NA objective. This technique has been characterized by polarimetry imaging at the back focal plane of the focusing objective, and modeled theoretically. 3D polarized fluorescence microscopy is demonstrated on actin stress fibers in non-flat cells suspended on synthetic polymer structures forming supporting pillars, for which heterogeneous actin orientational order could be identified. This technique shows a great potential in structural investigations in 3D biological systems, such as cell spheroids and tissues.

  8. 9 CFR 113.51 - Requirements for primary cells used for production of biologics.

    Science.gov (United States)

    2010-01-01

    ... biological product shall be shown free of mycoplasma as prescribed in § 113.28. The sample for testing shall...) Monolayers of avian origin shall be maintained for at least 14 days and shall be subcultured at least once.... (ii) Monolayers not of avian origin shall be maintained for at least 28 days and shall be...

  9. A direct solid sampling analysis method for the detection of silver nanoparticles in biological matrices.

    Science.gov (United States)

    Feichtmeier, Nadine S; Ruchter, Nadine; Zimmermann, Sonja; Sures, Bernd; Leopold, Kerstin

    2016-01-01

    Engineered silver nanoparticles (AgNPs) are implemented in food contact materials due to their powerful antimicrobial properties and so may enter the human food chain. Hence, it is desirable to develop easy, sensitive and fast analytical screening methods for the determination of AgNPs in complex biological matrices. This study describes such a method using solid sampling high-resolution continuum source graphite furnace atomic absorption spectrometry (GFAAS). A recently reported novel evaluation strategy uses the atomization delay of the respective GFAAS signal as significant indicator for AgNPs and thereby allows discrimination of AgNPs from ionic silver (Ag(+)) in the samples without elaborate sample pre-treatment. This approach was further developed and applied to a variety of biological samples. Its suitability was approved by investigation of eight different food samples (parsley, apple, pepper, cheese, onion, pasta, maize meal and wheat flour) spiked with ionic silver or AgNPs. Furthermore, the migration of AgNPs from silver-impregnated polypropylene food storage boxes to fresh pepper was observed and a mussel sample obtained from a laboratory exposure study with silver was investigated. The differences in the atomization delays (Δt(ad)) between silver ions and 20-nm AgNPs vary in a range from -2.01 ± 1.38 s for maize meal to +2.06 ± 1.08 s for mussel tissue. However, the differences were significant in all investigated matrices and so indicative of the presence/absence of AgNPs. Moreover, investigation of model matrices (cellulose, gelatine and water) gives the first indication of matrix-dependent trends. Reproducibility and homogeneity tests confirm the applicability of the method. PMID:26483187

  10. Stability of heroin, 6-monoacetylmorphine, and morphine in biological samples and validation of an LC–MS assay for delayed analyses of pharmacokinetic samples in rats

    OpenAIRE

    Jones, Jessica M.; Raleigh, Michael D.; Pentel, Paul R.; Harmon, Theresa M.; Keyler, Daniel E.; Remmel, Rory P.; Birnbaum, Angela K

    2012-01-01

    Degradation of heroin to 6-monoacetylmorphine (6-MAM) and then morphine happens rapidly in vivo and in vitro. The rates of heroin and 6-MAM degradation depend on the type of biological samples, and the duration and conditions of storage. In order to optimize conditions for measuring heroin and its metabolites in samples collected for pharmacokinetic studies in rats, we investigated the time course of degradation of heroin, 6-MAM, and morphine in four biological matrices: rat blood, rat brain ...

  11. Monitoring prion protein expression in complex biological samples by SERS for diagnostic applications

    International Nuclear Information System (INIS)

    Surface-enhanced Raman spectroscopy (SERS) allows a new insight into the analysis of cell physiology. In this work, the difficulty of producing suitable substrates that, besides permitting the amplification of the Raman signal, do not interact with the biological material causing alteration, has been overcome by a combined method of hydrothermal green synthesis and thermal annealing. The SERS analysis of the cell membrane has been performed with special attention to the cellular prion protein PrPC. In addition, SERS has also been used to reveal the prion protein-Cu(II) interaction in four different cell models (B104, SH-SY5Y, GN11, HeLa), expressing PrPC at different levels. A significant implication of the current work consists of the intriguing possibility of revealing and quantifying prion protein expression in complex biological samples by a cheap SERS-based method, replacing the expensive and time-consuming immuno-assay systems commonly employed.

  12. Bayesian model comparison and parameter inference in systems biology using nested sampling.

    Science.gov (United States)

    Pullen, Nick; Morris, Richard J

    2014-01-01

    Inferring parameters for models of biological processes is a current challenge in systems biology, as is the related problem of comparing competing models that explain the data. In this work we apply Skilling's nested sampling to address both of these problems. Nested sampling is a Bayesian method for exploring parameter space that transforms a multi-dimensional integral to a 1D integration over likelihood space. This approach focuses on the computation of the marginal likelihood or evidence. The ratio of evidences of different models leads to the Bayes factor, which can be used for model comparison. We demonstrate how nested sampling can be used to reverse-engineer a system's behaviour whilst accounting for the uncertainty in the results. The effect of missing initial conditions of the variables as well as unknown parameters is investigated. We show how the evidence and the model ranking can change as a function of the available data. Furthermore, the addition of data from extra variables of the system can deliver more information for model comparison than increasing the data from one variable, thus providing a basis for experimental design. PMID:24523891

  13. Bayesian model comparison and parameter inference in systems biology using nested sampling.

    Directory of Open Access Journals (Sweden)

    Nick Pullen

    Full Text Available Inferring parameters for models of biological processes is a current challenge in systems biology, as is the related problem of comparing competing models that explain the data. In this work we apply Skilling's nested sampling to address both of these problems. Nested sampling is a Bayesian method for exploring parameter space that transforms a multi-dimensional integral to a 1D integration over likelihood space. This approach focuses on the computation of the marginal likelihood or evidence. The ratio of evidences of different models leads to the Bayes factor, which can be used for model comparison. We demonstrate how nested sampling can be used to reverse-engineer a system's behaviour whilst accounting for the uncertainty in the results. The effect of missing initial conditions of the variables as well as unknown parameters is investigated. We show how the evidence and the model ranking can change as a function of the available data. Furthermore, the addition of data from extra variables of the system can deliver more information for model comparison than increasing the data from one variable, thus providing a basis for experimental design.

  14. Rapid methods to detect organic mercury and total selenium in biological samples

    Directory of Open Access Journals (Sweden)

    Basu Niladri

    2011-01-01

    Full Text Available Abstract Background Organic mercury (Hg is a global pollutant of concern and selenium is believed to afford protection against mercury risk though few approaches exist to rapidly assess both chemicals in biological samples. Here, micro-scale and rapid methods to detect organic mercury ( Results For organic Hg, samples are digested using Tris-HCl buffer (with sequential additions of protease, NaOH, cysteine, CuSO4, acidic NaBr followed by extraction with toluene and Na2S2O3. The final product is analyzed via commercially available direct/total mercury analyzers. For Se, a fluorometric assay has been developed for microplate readers that involves digestion (HNO3-HClO4 and HCl, conjugation (2,3-diaminonaphthalene, and cyclohexane extraction. Recovery of organic Hg (86-107% and Se (85-121% were determined through use of Standard Reference Materials and lemon shark kidney tissues. Conclusions The approaches outlined provide an easy, rapid, reproducible, and cost-effective platform for monitoring organic Hg and total Se in biological samples. Owing to the importance of organic Hg and Se in the pathophysiology of Hg, integration of such methods into established research monitoring efforts (that largely focus on screening total Hg only will help increase understanding of Hg's true risks.

  15. Analytical approaches for assaying metallodrugs in biological samples: recent methodological developments and future trends.

    Science.gov (United States)

    Timerbaev, Andrei; Sturup, Stefan

    2012-03-01

    Contemporary medicine increasingly relies on metal-based drugs and correspondingly growing in importance is the monitoring of the drugs and their metabolites in biological samples. Over the last decade, a range of analytical techniques have been developed in order to improve administration strategies for clinically approved compounds and understand pharmacokinetics, pharmacodynamics, and metabolism of new drugs so as ultimately to make their clinical development more effective. This paper gives an overview of various separation and detection methods, as well as common sample preparation strategies, currently in use to achieve the intended goals. The critical discussion of existing analytical technologies encompasses notably their detection capability, ability to handle biological matrices with minimum pretreatment, sample throughput, and cost efficiency. The main attention is devoted to those applications that are progressed to real-world biosamples and selected examples are given to illustrate the overall performance and applicability of advanced analytical systems. Also emphasized is the emerging role of inductively coupled plasma mass spectrometry (ICP-MS), both as a standalone instrument (for determination of metals originating from drug compounds) and as an element-specific detector in combinations with liquid chromatography or capillary electrophoresis (for drug metabolism studies). An increasing number of academic laboratories are using ICP-MS technology today, and this review will focus on the analytical possibilities of ICP-MS which would before long provide the method with the greatest impact on the clinical laboratory. PMID:21838702

  16. 76 FR 36019 - Amendments to Sterility Test Requirements for Biological Products

    Science.gov (United States)

    2011-06-21

    ... or other material (e.g., bulk material or active pharmaceutical ingredient (API), in-process material... November 20, 1973 (38 FR 32048), we reorganized and republished the biologics regulations, which included... requirements. On March 11, 1976 (41 FR 10427) and March 2, 1979 (44 FR 11754), we updated Sec. 610.12...

  17. Magnetic induction spectroscopy: non-contact measurement of the electrical conductivity spectra of biological samples

    International Nuclear Information System (INIS)

    Measurement of the electrical conductivity of biological tissues as a function of frequency, often termed ‘bioelectrical impedance spectroscopy (BIS)’, provides valuable information on tissue structure and composition. In implementing BIS though, there can be significant practical difficulties arising from the electrode–sample interface which have likely limited its deployment in industrial applications. In magnetic induction spectroscopy (MIS) these difficulties are eliminated through the use of fully non-contacting inductive coupling between the sensors and sample. However, inductive coupling introduces its own set of technical difficulties, primarily related to the small magnitudes of the induced currents and their proportionality with frequency. This paper describes the design of a practical MIS system incorporating new, highly-phase-stable electronics and compares its performance with that of electrode-based BIS in measurements on biological samples including yeast suspensions in saline (concentration 50–400 g l−1) and solid samples of potato, cucumber, tomato, banana and porcine liver. The shapes of the MIS spectra were in good agreement with those for electrode-based BIS, with a residual maximum discrepancy of 28%. The measurement precision of the MIS was 0.05 S m−1 at 200 kHz, improving to 0.01 S m−1 at a frequency of 20 MHz, for a sample volume of 80 ml. The data-acquisition time for each MIS measurement was 52 s. Given the value of spectroscopic conductivity information and the many advantages of obtaining these data in a non-contacting manner, even through electrically-insulating packaging materials if necessary, it is concluded that MIS is a technique with considerable potential for monitoring bio-industrial processes and product quality. (paper)

  18. 3D nanoscale imaging of biological samples with laboratory-based soft X-ray sources

    Science.gov (United States)

    Dehlinger, Aurélie; Blechschmidt, Anne; Grötzsch, Daniel; Jung, Robert; Kanngießer, Birgit; Seim, Christian; Stiel, Holger

    2015-09-01

    In microscopy, where the theoretical resolution limit depends on the wavelength of the probing light, radiation in the soft X-ray regime can be used to analyze samples that cannot be resolved with visible light microscopes. In the case of soft X-ray microscopy in the water-window, the energy range of the radiation lies between the absorption edges of carbon (at 284 eV, 4.36 nm) and oxygen (543 eV, 2.34 nm). As a result, carbon-based structures, such as biological samples, posses a strong absorption, whereas e.g. water is more transparent to this radiation. Microscopy in the water-window, therefore, allows the structural investigation of aqueous samples with resolutions of a few tens of nanometers and a penetration depth of up to 10μm. The development of highly brilliant laser-produced plasma-sources has enabled the transfer of Xray microscopy, that was formerly bound to synchrotron sources, to the laboratory, which opens the access of this method to a broader scientific community. The Laboratory Transmission X-ray Microscope at the Berlin Laboratory for innovative X-ray technologies (BLiX) runs with a laser produced nitrogen plasma that emits radiation in the soft X-ray regime. The mentioned high penetration depth can be exploited to analyze biological samples in their natural state and with several projection angles. The obtained tomogram is the key to a more precise and global analysis of samples originating from various fields of life science.

  19. Non-destructive high-resolution thermal imaging techniques to evaluate wildlife and delicate biological samples

    Energy Technology Data Exchange (ETDEWEB)

    Lavers, C; Franklin, P; Franklin, P; Plowman, A; Sayers, G; Bol, J; Shepard, D; Fields, D, E-mail: brnc-radarcomms1@nrta.mod.u [Sensors Team, Plymouth University at Britannia Royal Naval College, Dartmouth, Devon (United Kingdom) and Paignton Zoological Park, Paignton, Devon (United Kingdom); Thermal Wave Imaging, Inc., 845 Livernoise St, Ferndale, MI (United States); Buckfast Butterfly and Otter Sanctuary, Buckfast, Devon (United Kingdom)

    2009-07-01

    Thermal imaging cameras now allows routine monitoring of dangerous yet endangered wildlife in captivity. This study looks at the potential applications of radiometrically calibrated thermal data to wildlife, as well as providing parameters for future materials applications. We present a non-destructive active testing technique suitable for enhancing imagery contrast of thin or delicate biological specimens yielding improved thermal contrast at room temperature, for analysis of sample thermal properties. A broad spectrum of animals is studied with different textured surfaces, reflective and emissive properties in the infra red part of the electromagnetic spectrum. Some surface features offer biomimetic materials design opportunities.

  20. Quenching effect of iron on uranium concentration measurements by fluorimetry in biological samples

    International Nuclear Information System (INIS)

    Iron is considered as a strong quencher that reduce the uranium fluorescence in biological sample. This effect was studied by two methods. In the first method iron concentration was fixed to study the effect on different uranium standard solutions. In the second method the concentration of uranium standard solutions were fixed while different amounts of iron were added if has been found that the quenching effect of iron is the same in low concentration of uranium, while in high concentration of uranium the quenching effect is greater. (author). 1 ref., 4 tabs

  1. Imaging material properties of biological samples with a Force Feedback Microscope

    CERN Document Server

    Costa, Luca; Newman, Emily; Zubieta, Chloe; Chevrier, Joel; Comin, Fabio

    2013-01-01

    Mechanical properties of biological samples have been imaged with a force feedback microscope. The force, force gradient and the dissipation are simultaneously measured quantitatively from solely the knowledge of the spring constant. The results are preliminary but demonstrate that the method can be used to measure material properties, it is robust and produce quantitative high force resolution measurements of interaction characteristics. The small stiffness and oscillation of the cantilever results in an vibrational energy much smaller than the thermal energy, reducing the interaction to a minimum. Because the lever is over-damped, the excitation frequency can be chosen arbitrarily.

  2. On the Applications of IBA Techniques to Biological Samples Analysis: PIXE and RBS

    International Nuclear Information System (INIS)

    The analytical techniques based on ion beams or IBA techniques give quantitative information on elemental concentration in samples of a wide variety of nature. In this work, we focus on PIXE technique, analyzing thick target biological specimens (TTPIXE), using 3 MeV protons produced by an electrostatic accelerator. A nuclear microprobe was used performing PIXE and RBS simultaneously, in order to solve the uncertainties produced in the absolute PIXE quantifying. The advantages of using both techniques and a nuclear microprobe are discussed. Quantitative results are shown to illustrate the multielemental resolution of the PIXE technique; for this, a blood standard was used

  3. Separation Technique for the Determination of Highly Polar Metabolites in Biological Samples

    Directory of Open Access Journals (Sweden)

    Yusuke Iwasaki

    2012-08-01

    Full Text Available Metabolomics is a new approach that is based on the systematic study of the full complement of metabolites in a biological sample. Metabolomics has the potential to fundamentally change clinical chemistry and, by extension, the fields of nutrition, toxicology, and medicine. However, it can be difficult to separate highly polar compounds. Mass spectrometry (MS, in combination with capillary electrophoresis (CE, gas chromatography (GC, or high performance liquid chromatography (HPLC is the key analytical technique on which emerging "omics" technologies, namely, proteomics, metabolomics, and lipidomics, are based. In this review, we introduce various methods for the separation of highly polar metabolites.

  4. Three approaches for direct analysis of biological samples by Total reflection X-Ray Fluorescence analysis

    International Nuclear Information System (INIS)

    One of the main advantages of the Total reflection X-Ray Fluorescence technique is feasibility of the direct analysis of the sample. taking in account this fact, three methods for the direct analysis of biological samples were evaluated For the evaluation of the method of Compton peak standardization serum, brain tissue, urine and amniotic fluid matrices were analyzed using compton Peak and the elements Co, and V as internal standard. In the case the sample itself is used as calibration standard. The method is reliable for the analysis of serum and brain tissue samples. The analytical quality of the results was similar to that obtained by the conventional method. The results were in good agreements with those obtained by the atomic absorption technique. The second method was applied to the certified Bovine Liver Standard sample 1577a. Experimental conditions for the microwave acid digestion of the solid sample directly on the quartz reflector were found, The percent of recovery of the elements S, Ci, K, Ca, Mn, Fe, Cu, Zn, Se, Br, and Rb carried between 85% and 115% and The precision was below the 10% of relative standards deviations for ten independent replicates. In the third method the concept of chemical modifications is adapted to the Total reflection X-Ray Fluorescence technique. In these experiments the main objective was the elimination of Chlorine from the matrix following the in situ addition of the reactive ammonium nitrate and heating. The method was applied to high saline content samples, i.e. amniotic fluid samples, Special care was given to the volatile elements and to the quality of the thin layer. an enhancement of the sensitivity was found for those elements with signals near the chlorine k-Alfa signal after the modifications procedure

  5. Sample sizing of biological materials analyzed by energy dispersion X-ray fluorescence

    International Nuclear Information System (INIS)

    Analytical portions used in chemical analyses are usually less than 1g. Errors resulting from the sampling are barely evaluated, since this type of study is a time-consuming procedure, with high costs for the chemical analysis of large number of samples. The energy dispersion X-ray fluorescence - EDXRF is a non-destructive and fast analytical technique with the possibility of determining several chemical elements. Therefore, the aim of this study was to provide information on the minimum analytical portion for quantification of chemical elements in biological matrices using EDXRF. Three species were sampled in mangroves from the Pernambuco, Brazil. Tree leaves were washed with distilled water, oven-dried at 60 deg C and milled until 0.5 mm particle size. Ten test-portions of approximately 500 mg for each species were transferred to vials sealed with polypropylene film. The quality of the analytical procedure was evaluated from the reference materials IAEA V10 Hay Powder, SRM 2976 Apple Leaves. After energy calibration, all samples were analyzed under vacuum for 100 seconds for each group of chemical elements. The voltage used was 15 kV and 50 kV for chemical elements of atomic number lower than 22 and the others, respectively. For the best analytical conditions, EDXRF was capable of estimating the sample size uncertainty for further determination of chemical elements in leaves. (author)

  6. Microwave-assisted digestion procedures for biological samples with diluted nitric acid: identification of reaction products.

    Science.gov (United States)

    Gonzalez, Mário H; Souza, Gilberto B; Oliveira, Regina V; Forato, Lucimara A; Nóbrega, Joaquim A; Nogueira, Ana Rita A

    2009-07-15

    Microwave-assisted sample preparation using diluted nitric acid solutions is an alternative procedure for digesting organic samples. The efficiency of this procedure depends on the chemical properties of the samples and in this work it was evaluated by the determination of crude protein amount, fat and original carbon. Soybeans grains, bovine blood, bovine muscle and bovine viscera were digested in a cavity-microwave oven using oxidant mixtures in different acid concentrations. The digestion efficiency was evaluated based on the determination of residual carbon content and element recoveries using inductively coupled plasma optical emission spectrometry (ICP OES). In order to determine the main residual organic compounds, the digests were characterized by nuclear magnetic resonance ((1)H NMR). Subsequently, studies concerning separation of nitrobenzoic acid isomers were performed by ion pair reversed phase liquid chromatography using a C18 stationary phase, water:acetonitrile:methanol (75:20:5, v/v/v)+0.05% (v/v) TFA as mobile phase and ultraviolet detection at 254 nm. Sample preparation based on diluted acids proved to be feasible and a recommendable alternative for organic sample digestion, reducing both the reagent volumes and the variability of the residues as a result of the process of decomposition. It was shown that biological matrices containing amino acids, proteins and lipids in their composition produced nitrobenzoic acid isomers and other organic compounds after cleavage of chemical bonds. PMID:19559896

  7. Sample sizing of biological materials analyzed by energy dispersion X-ray fluorescence

    Energy Technology Data Exchange (ETDEWEB)

    Paiva, Jose D.S.; Franca, Elvis J.; Magalhaes, Marcelo R.L.; Almeida, Marcio E.S.; Hazin, Clovis A., E-mail: dan-paiva@hotmail.com, E-mail: ejfranca@cnen.gov.br, E-mail: marcelo_rlm@hotmail.com, E-mail: maensoal@yahoo.com.br, E-mail: chazin@cnen.gov.b [Centro Regional de Ciencias Nucleares do Nordeste (CRCN-NE/CNEN-PE), Recife, PE (Brazil)

    2013-07-01

    Analytical portions used in chemical analyses are usually less than 1g. Errors resulting from the sampling are barely evaluated, since this type of study is a time-consuming procedure, with high costs for the chemical analysis of large number of samples. The energy dispersion X-ray fluorescence - EDXRF is a non-destructive and fast analytical technique with the possibility of determining several chemical elements. Therefore, the aim of this study was to provide information on the minimum analytical portion for quantification of chemical elements in biological matrices using EDXRF. Three species were sampled in mangroves from the Pernambuco, Brazil. Tree leaves were washed with distilled water, oven-dried at 60 deg C and milled until 0.5 mm particle size. Ten test-portions of approximately 500 mg for each species were transferred to vials sealed with polypropylene film. The quality of the analytical procedure was evaluated from the reference materials IAEA V10 Hay Powder, SRM 2976 Apple Leaves. After energy calibration, all samples were analyzed under vacuum for 100 seconds for each group of chemical elements. The voltage used was 15 kV and 50 kV for chemical elements of atomic number lower than 22 and the others, respectively. For the best analytical conditions, EDXRF was capable of estimating the sample size uncertainty for further determination of chemical elements in leaves. (author)

  8. ASPIRE: An automated sample positioning and irradiation system for radiation biology experiments at Inter University Accelerator Centre, New Delhi

    International Nuclear Information System (INIS)

    An automated irradiation setup for biology samples has been built at Inter University Accelerator Centre (IUAC), New Delhi, India. It can automatically load and unload 20 biology samples in a run of experiment. It takes about 20 min [2% of the cell doubling time] to irradiate all the 20 samples. Cell doubling time is the time taken by the cells (kept in the medium) to grow double in numbers. The cells in the samples keep growing during entire of the experiment. The fluence irradiated to the samples is measured with two silicon surface barrier detectors. Tests show that the uniformity of fluence and dose of heavy ions reaches to 2% at the sample area in diameter of 40 mm. The accuracy of mean fluence at the center of the target area is within 1%. The irradiation setup can be used to the studies of radiation therapy, radiation dosimetry and molecular biology at the heavy ion accelerator. - Highlights: • Automated positioning and irradiation setup for biology samples at IUAC is built. • Loading and unloading of 20 biology samples can be automatically carried out. • Biologicals cells keep growing during entire experiment. • Fluence and dose of heavy ions are measured by two silicon barrier detectors. • Uniformity of fluence and dose of heavy ions at sample position reaches to 2%

  9. Combined LIBS-Raman for remote detection and characterization of biological samples

    Science.gov (United States)

    Anderson, Aaron S.; Mukundan, Harshini; McInroy, Rhonda E.; Clegg, Samuel M.

    2015-03-01

    Laser-Induced Breakdown Spectroscopy (LIBS) and Raman Spectroscopy have rich histories in the analysis of a wide variety of samples in both in situ and remote configurations. Our team is working on building a deployable, integrated Raman and LIBS spectrometer (RLS) for the parallel elucidation of elemental and molecular signatures under Earth and Martian surface conditions. Herein, results from remote LIBS and Raman analysis of biological samples such as amino acids, small peptides, mono- and disaccharides, and nucleic acids acquired under terrestrial and Mars conditions are reported, giving rise to some interesting differences. A library of spectra and peaks of interest were compiled, and will be used to inform the analysis of more complex systems, such as large peptides, dried bacterial spores, and biofilms. These results will be presented and future applications will be discussed, including the assembly of a combined RLS spectroscopic system and stand-off detection in a variety of environments.

  10. Towards a new method for the quantification of metabolites in the biological sample

    International Nuclear Information System (INIS)

    The quantification of metabolites is a key step in drug development. The aim of this Ph.D. work was to study the feasibility of a new method for this quantification, in the biological sample, without the drawbacks (cost, time, ethics) of the classical quantification methods based on metabolites synthesis or administration to man of the radiolabelled drug. Our strategy consists in determining the response factor, in mass spectrometry, of the metabolites. This approach is based on tritium labelling of the metabolites, ex vivo, by isotopic exchange. The labelling step was studied with deuterium. Metabolites of a model drug, recovered from in vitro or urinary samples, were labelled by three ways (Crab tree's catalyst ID2, deuterated trifluoroacetic acid or rhodium chloride ID20). Then, the transposition to tritium labelling was studied and the first results are very promising for the ultimate validation of the method. (author)

  11. Enzymatic determination of carbon-14 labeled L-alanine in biological samples

    International Nuclear Information System (INIS)

    A method for determination of L-alanine-specific radioactivity in biological samples is presented. This method is based on the specific enzymatic transformation of L-alanine to pyruvic acid hydrazone catalyzed by the enzyme L-alanine dehydrogenase, formation of the pyruvic acid 2,4-dinitrophenylhydrazone derivative, and quantitative trapping in Amberlite XAD-7 columns, followed by radioactivity counting of the lipophilic eluate. No interferences from other 14C-labeled materials such as D-glucose, glycerol, L-lactate, L-serine, L-glutamate, L-phenylalanine, glycine, L-leucine, and L-arginine were observed. This inexpensive and high-speed method is applicable to the simultaneous determination of L-alanine-specific radioactivity for a large number of samples

  12. Enzymatic determination of carbon-14 labeled L-alanine in biological samples

    Energy Technology Data Exchange (ETDEWEB)

    Serra, F.; Palou, A.; Pons, A.

    1987-07-15

    A method for determination of L-alanine-specific radioactivity in biological samples is presented. This method is based on the specific enzymatic transformation of L-alanine to pyruvic acid hydrazone catalyzed by the enzyme L-alanine dehydrogenase, formation of the pyruvic acid 2,4-dinitrophenylhydrazone derivative, and quantitative trapping in Amberlite XAD-7 columns, followed by radioactivity counting of the lipophilic eluate. No interferences from other UC-labeled materials such as D-glucose, glycerol, L-lactate, L-serine, L-glutamate, L-phenylalanine, glycine, L-leucine, and L-arginine were observed. This inexpensive and high-speed method is applicable to the simultaneous determination of L-alanine-specific radioactivity for a large number of samples.

  13. Preparation of chitosan grafted graphite composite for sensitive detection of dopamine in biological samples.

    Science.gov (United States)

    Palanisamy, Selvakumar; Thangavelu, Kokulnathan; Chen, Shen-Ming; Gnanaprakasam, P; Velusamy, Vijayalakshmi; Liu, Xiao-Heng

    2016-10-20

    The accurate detection of dopamine (DA) levels in biological samples such as human serum and urine are essential indicators in medical diagnostics. In this work, we describe the preparation of chitosan (CS) biopolymer grafted graphite (GR) composite for the sensitive and lower potential detection of DA in its sub micromolar levels. The composite modified electrode has been used for the detection of DA in biological samples such as human serum and urine. The GR-CS composite modified electrode shows an enhanced oxidation peak current response and low oxidation potential for the detection of DA than that of electrodes modified with bare, GR and CS discretely. Under optimum conditions, the fabricated GR-CS composite modified electrode shows the DPV response of DA in the linear response ranging from 0.03 to 20.06μM. The detection limit and sensitivity of the sensor were estimated as 0.0045μM and 6.06μA μM(-1)cm(-2), respectively. PMID:27474582

  14. Separation and enrichment of trace ractopamine in biological samples by uniformly-sized molecularly imprinted polymers

    Institute of Scientific and Technical Information of China (English)

    Ya Li; Qiang Fua; Meng Liu; Yuan-Yuan Jiao; Wei Du; Chong Yu; Jing Liu; Chun Chang; Jian Lu

    2012-01-01

    In order to prepare a high capacity packing material for solid-phase extraction with specific recognition ability of trace ractopamine in biological samples, uniformly-sized, molecularly imprinted polymers (MIPs) were prepared by a multi-step swelling and polymerization method using methacrylic acid as a functional monomer, ethylene glycol dimethacrylate as a cross-linker, and toluene as a porogen respectively. Scanning electron microscope and specific surface area were employed to identify the characteristics of MIPs. Ultraviolet spectroscopy, Fourier transform infrared spectroscopy, Scatchard analysis and kinetic study were performed to interpret the specific recognition ability and the binding process of MIPs. The results showed that, compared with other reports, MIPs synthetized in this study showed high adsorption capacity besides specific recognition ability. The adsorption capacity of MIPs was 0.063 mmol/g at 1 mmol/L ractopamine concentra- tion with the distribution coefficient 1.70. The resulting MIPs could be used as solid-phase extraction materials for separation and enrichment of trace ractopamine in biological samples.

  15. Computer program for sample sizes required to determine disease incidence in fish populations

    Science.gov (United States)

    Ossiander, Frank J.; Wedemeyer, Gary

    1973-01-01

    A computer program is described for generating the sample size tables required in fish hatchery disease inspection and certification. The program was designed to aid in detection of infectious pancreatic necrosis (IPN) in salmonids, but it is applicable to any fish disease inspection when the sampling plan follows the hypergeometric distribution.

  16. Probabilistic Requirements (Partial) Verification Methods Best Practices Improvement. Variables Acceptance Sampling Calculators: Empirical Testing. Volume 2

    Science.gov (United States)

    Johnson, Kenneth L.; White, K. Preston, Jr.

    2012-01-01

    The NASA Engineering and Safety Center was requested to improve on the Best Practices document produced for the NESC assessment, Verification of Probabilistic Requirements for the Constellation Program, by giving a recommended procedure for using acceptance sampling by variables techniques as an alternative to the potentially resource-intensive acceptance sampling by attributes method given in the document. In this paper, the results of empirical tests intended to assess the accuracy of acceptance sampling plan calculators implemented for six variable distributions are presented.

  17. Methylmercury determination in biological samples using electrothermal atomic absorption spectrometry after acid leaching extraction

    Energy Technology Data Exchange (ETDEWEB)

    Saber-Tehrani, Mohammad; Hashemi-Moghaddam, Hamid; Givianrad, Mohammad Hadi; Abroomand-Azar, Parviz [Islamic Azad University, Department of Chemistry, Science and Research Branch, Tehran (Iran)

    2006-11-15

    An efficient and sensitive method for the determination of methylmercury in biological samples was developed based on acid leaching extraction of methylmercury into toluene. Methylmercury in the organic phase was determined by electrothermal atomic absorption spectrometry (ETAAS). The methylmercury signal was enhanced and the reproducibility increased by formation of certain complexes and addition of Pd-DDC modifier. The complex of methylmercury with DDC produced the optimum analytical signal in terms of sensitivity and reproducibility compared to complexes with dithizone, cysteine, 1,10-phenanthroline, and diethyldithiocarbamate. Method performance was optimized by modifying parameters such as temperature of mineralization, atomization, and gas flow rate. The limit of detection for methylmercury determination was 0.015 {mu}g g{sup -1} and the RSD of the whole procedure was 12% for human teeth samples (n=5) and 15.8% for hair samples (n=5). The method's accuracy was investigated by using NIES-13 and by spiking the samples with different amounts of methylmercury. The results were in good agreement with the certified values and the recoveries were 88-95%. (orig.)

  18. Label-free three-dimensional reconstruction of biological samples (Conference Presentation)

    Science.gov (United States)

    Aknoun, Sherazade; Bon, Pierre; Savatier, Julien; Monneret, Serge; Wattellier, Benoit F.

    2016-03-01

    We describe the use of spatially incoherent illumination combined with quantitative phase imaging (QPI) [1] to make tridimensional reconstruction of semi-transparent biological samples. Quantitative phase imaging is commonly used with coherent illumination for the relatively simple interpretation of the phase measurement. We propose to use spatially incoherent illumination which is known to increase lateral and axial resolution compared to classical coherent illumination. The goal is to image thick samples with intracellular resolution [2]. The 3D volume is imaged by axially scanning the sample with a quadri-wave lateral shearing interferometer used as a conventional camera while using spatially incoherent white-light illumination (native microscope halogen source) or NIR light. We use a non-modified inverted microscope equipped with a Z-axis piezo stage. A z-stack is recorded by objective translation along the optical axis. The main advantages of this approach are its easy implementation, compared to the other state-of-the-art diffraction tomographic setups, and its speed which makes even label-free 3D living sample imaging possible. A deconvolution algorithm is used to compensate for the loss in contrast due to spatially incoherent illumination. This makes the tomographic volume phase values quantitative. Hence refractive index could be recovered from the optical slices. We will present tomographic reconstruction of cells, thick fixed tissue of few tens of micrometers using white light, and the use of NIR light to reach deeper planes in the tissue.

  19. Label-free three dimensional reconstruction of biological samples (Conference Presentation)

    Science.gov (United States)

    Aknoun, Sherazade; Bon, Pierre; Savatier, Julien; Monneret, Serge; Wattellier, Benoit F.

    2016-03-01

    We describe the use of spatially incoherent illumination combined with quantitative phase imaging (QPI) [1] to make tridimensional reconstruction of semi-transparent biological samples. Quantitative phase imaging is commonly used with coherent illumination for the relatively simple interpretation of the phase measurement. We propose to use spatially incoherent illumination which is known to increase lateral and axial resolution compared to classical coherent illumination. The goal is to image thick samples with intracellular resolution [2]. The 3D volume is imaged by axially scanning the sample with a quadri-wave lateral shearing interferometer used as a conventional camera while using spatially incoherent white-light illumination (native microscope halogen source) or NIR light. We use a non-modified inverted microscope equipped with a Z-axis piezo stage. A z-stack is recorded by objective translation along the optical axis. The main advantages of this approach are its easy implementation, compared to the other state-of-the-art diffraction tomographic setups, and its speed which makes even label-free 3D living sample imaging possible. A deconvolution algorithm is used to compensate for the loss in contrast due to spatially incoherent illumination. This makes the tomographic volume phase values quantitative. Hence refractive index could be recovered from the optical slices. We will present tomographic reconstruction of cells, thick fixed tissue of few tens of micrometers using white light, and the use of NIR light to reach deeper planes in the tissue.

  20. 40 CFR 80.335 - What gasoline sample retention requirements apply to refiners and importers?

    Science.gov (United States)

    2010-07-01

    ... certify that the procedures meet the requirements of the ASTM procedures required under 40 CFR 80.330. (d... 40 Protection of Environment 16 2010-07-01 2010-07-01 false What gasoline sample retention... PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) REGULATION OF FUELS AND FUEL ADDITIVES Gasoline...

  1. The study of trace element distribution in biological samples with NAA for human health

    International Nuclear Information System (INIS)

    A one day representative mixed diet of an adult Korean was collected from the data based on the food intake of 108 healthy subjects between the ages 20 and 50. Sampling for the Korean total diet was carried out by the way of using a market basket study based on the Korean standard food consumption scheme reported by the Korean Nutrition Society. Average consumption frequency of different food items for a one day representative mixed diet of an adult Korean and the amount of each item to prepare a one day Korean representative total diet are surveyed. The analytical methods involve both instrumental and radiochemical neutron activation techniques developed for the determination of the elements Cs, I, Sr, Th and U in various kinds of food samples. Concentrations of trace elements including 5 important elements for radiological protection, U, Th, Cs, Sr and I in the Korean total diet and the 4 most frequently consumed Korean foodstuffs have been analyzed by neutron activation analysis. Detection limits for U, Th, Sr and I were improved to ppb levels by radiochemical separation after neutron irradiation. Five biological NIST reference materials were also analyzed for quality control of the analysis. Seventeen trace elements in the Korean total diet and four Korean representative foodstuffs were also analyzed quantitatively by instrumental neutron activation analysis. The elemental distributions in supplemental healthy food and Korean and Chinese origin oriental medicine were also identified. The amount of trace elements ingested with the hair analysis of oriental medicine takers were estimated. The amounts of trace elements inhaled with the analysis of foundry air, blood and hair of foundry workers were also estimated. The basic estimation method in view of health and environment with the neutron activation analysis of biological samples such as foods and hair was established with the result. Nationwide usage system of the NAA facility in Hanaro in many different and

  2. Molecular dynamics simulations of biological membranes and membrane proteins using enhanced conformational sampling algorithms.

    Science.gov (United States)

    Mori, Takaharu; Miyashita, Naoyuki; Im, Wonpil; Feig, Michael; Sugita, Yuji

    2016-07-01

    This paper reviews various enhanced conformational sampling methods and explicit/implicit solvent/membrane models, as well as their recent applications to the exploration of the structure and dynamics of membranes and membrane proteins. Molecular dynamics simulations have become an essential tool to investigate biological problems, and their success relies on proper molecular models together with efficient conformational sampling methods. The implicit representation of solvent/membrane environments is reasonable approximation to the explicit all-atom models, considering the balance between computational cost and simulation accuracy. Implicit models can be easily combined with replica-exchange molecular dynamics methods to explore a wider conformational space of a protein. Other molecular models and enhanced conformational sampling methods are also briefly discussed. As application examples, we introduce recent simulation studies of glycophorin A, phospholamban, amyloid precursor protein, and mixed lipid bilayers and discuss the accuracy and efficiency of each simulation model and method. This article is part of a Special Issue entitled: Membrane Proteins edited by J.C. Gumbart and Sergei Noskov. PMID:26766517

  3. Rare earth analysis in human biological samples by atomic absorption using electrothermal atomization

    International Nuclear Information System (INIS)

    The determination of Sc and seven rare earth elements, Nd, Sm, Dy, Ho, Eu, Tm, and Yb, in biological samplesby atomic absorption spectrophotometric analysis (AAS) using electrothermal atomization in a pyrolytic graphite tube is shown to be rapid, precise and accurate. The technique utilizes the method of standard additions and linear regression analysis to determine results from peak area data. Inter-elemental interferences are negligible. The elements found sensitive enough for this type of analysis are, in order of decreasing sensitivity, Yb, Eu, Tm, Dy, Sc, Ho, Sm and Nd. The determination in these types of materials of Gd and elements less sensitive to AAS detection than Gd does not appear to be feasible. Results are presented on the concentrations of these elements in 41 samples from human subjects, cows and vegetables with normal environmental exposure to the rare earth elements. The composite percent mean deviation in peak-area readings for all samples and all elements examined was 4%. The mean standard error in the results among samples was about 6.5%

  4. Early history of regulatory requirements for poultry biologics in the United States.

    Science.gov (United States)

    Espeseth, David A; Lasher, Hiram

    2010-12-01

    Congress passed the Virus-Serum-Toxin Act in 1913, giving the U.S. Department of Agriculture (USDA) authority to prevent the importation or interstate shipment of worthless, contaminated, dangerous, or harmful veterinary biological products. The passage of this act marked the beginning of regulatory requirements for veterinary biological products in the United States. In 1913, only a few biologics establishments produced products for the poultry industry. The first license issued by the USDA for a poultry product was in 1918 to the University of California, Berkeley, for fowlpox vaccine. The list of biological products for poultry grew slowly in the 1920s. However, this began to change with the licensing of laryngotracheitis vaccine in 1933; pigeonpox vaccine in 1939; several Newcastle disease vaccines (inactivated in 1946, Roakin strain in 1948, B1 strain in 1950, and La Sota strain in 1952); and the first bronchitis vaccine in 1953. With the development of these and other new products, the biologics industry began to move its emphasis on hog cholera serum and virus to one based on the production of numerous new vaccines and bacterial products. The USDA's approach to the regulation of biologics in the early 1950s was still geared to the production of hog cholera products; however, as a result of the intervention of a group of dedicated poultry scientists, who were concerned about the poor performance of Newcastle disease vaccines, this soon changed. This presentation describes the initiation and development of modern standards for poultry biologics that occurred as a result of this intervention. The development and improvement of standards and regulatory requirements to address mycoplasma, leukosis, and other extraneous virus contaminations in chicken embryo origin products are reviewed. The licensing of products to meet new and emerging disease problems in the poultry industry and the close interaction among research scientists, poultry industry, biologics

  5. Monitoring prion protein expression in complex biological samples by SERS for diagnostic applications

    Energy Technology Data Exchange (ETDEWEB)

    Manno, D; Filippo, E; Fiore, R; Serra, A [Dipartimento di Scienza dei Materiali, Universita del Salento, Lecce (Italy); Urso, E; Rizzello, A; Maffia, M [Dipartimento di Scienze e Tecnologie Biologiche ed Ambientali, Universita del Salento, Lecce (Italy)

    2010-04-23

    Surface-enhanced Raman spectroscopy (SERS) allows a new insight into the analysis of cell physiology. In this work, the difficulty of producing suitable substrates that, besides permitting the amplification of the Raman signal, do not interact with the biological material causing alteration, has been overcome by a combined method of hydrothermal green synthesis and thermal annealing. The SERS analysis of the cell membrane has been performed with special attention to the cellular prion protein PrP{sup C}. In addition, SERS has also been used to reveal the prion protein-Cu(II) interaction in four different cell models (B104, SH-SY5Y, GN11, HeLa), expressing PrP{sup C} at different levels. A significant implication of the current work consists of the intriguing possibility of revealing and quantifying prion protein expression in complex biological samples by a cheap SERS-based method, replacing the expensive and time-consuming immuno-assay systems commonly employed.

  6. Determination of rhenium in biological and environmental samples by radiochemical neutron activation analysis

    International Nuclear Information System (INIS)

    Radiochemical neutron activation procedures using liquid-liquid extraction with tetraphenylarsonium chloride in chloroform from 1 M HCl and solid extraction with ALIQUAT 336 incorporated in a polyacrylonitrile binding matrix from 0.1 M HCl were developed for accurate determination of rhenium in biological and environmental samples at the sub-ng.g-1 level. Concentrations of Re in the range of 0.1 to 2.4 ng.g-1 were determined in several botanical reference materials (RM), while in a RM of road dust a value of approx. 10 ng.g-1 was found. Significantly elevated values of Re, up to 90 ng.g-1, were found in seaweed (brown algae). Results for Re in the brown algae Fucus vesiculosus in which elevated 99Tc values had previously been determined suggest possible competition between Re and Tc in the accumulation process. (author)

  7. Double-stacked dielectric ring resonator for EPR measurements of biological samples

    Energy Technology Data Exchange (ETDEWEB)

    Jaworski, M.; Sienkiewicz, A. [Inst. of Physics, Polish Academy of Sciences, Warsaw (Poland); Scholes, C.P. [Chemistry Dept., State Univ. of New York at Albany, Albany, NY (United States)

    1997-12-31

    We discuss the microwave properties of a newly developed double-stacked dielectric ring resonator (DR) for applications in Electron Paramagnetic Resonance (EPR) spectroscopy. This design leads to a substantial improvement of the signal-to-noise ratio (S/N), as well as enables one to measure biological samples characterized by high dielectric losses and often limited in supply. The paper presents a new theoretical approach for calculating the resonant frequency, resonator filling factor and resonator Q-factor for the double DR system. The comparison of experimentally and theoretically determined technical parameters reveals a very good accuracy that is better than 1% for the resonant frequency. (author). 9 refs, 6 figs, 1 tab.

  8. Magnetically responsive polycaprolactone nanoparticles for progesterone screening in biological and environmental samples using gas chromatography.

    Science.gov (United States)

    Es'haghi, Zarrin; Nezhadali, Azizollah; Khatibi, Aram-Dokht

    2016-08-01

    A new Fe3O4/poly(є-caprolactone) (PCL) magnetite nanocomposite was fabricated and used as a sorbent for magnetically mediated PCL microspheres solid-phase extraction (MM-PCL-SPE) followed by gas chromatography-flame ionization detection (GC-FID) for monitoring of progesterone (PGN) hormone in biological and environmental matrices, namely blood serum, tap water, urine, and hospital wastewater. The nanomagnetite core of the sorbent was synthesized by a co-precipitation method. Magnetic nanoparticles (MNPs) were then microencapsulated with PCL microspheres using emulsion polymerization. The nanocomposite was characterized by scanning electron microscopy (SEM) and Fourier transform infrared spectroscopy (FTIR). The magnetite sorbent can be effectively dispersed in aqueous solution and attracted to an external magnetic field. The MM-PCL-SPE process for PGN assay involved (a) dispersion of the sorbent in the donor phase aqueous solution with sonication, (b) exposure to a magnetic field to collect sorbent that had adsorbed the analyte, and (c) solvent desorption of extracted PGN for GC-FID analysis. The work demonstrates the usefulness of MM-PCL-SPE in the rapid and sensitive monitoring of trace amounts of PGN in real samples. The limit of detection (LOD) and limit of quantification (LOQ) were 1.00 and 3.30 ng/mL, respectively. The relative recoveries in real samples were adequate. Linearity was observed over a wide range of 2.2-10,000.0 ng/mL in aqueous media and urine and 0.01-70.0 μg/mL in blood serum. Graphical Abstract In this research new Fe3O4/poly(є-caprolactone) (PCL) magnetite microspheres were developed as an efficient sorbent for solid-phase extraction of progesterone hormone in biological and environmental matrices. PMID:27299775

  9. Integrated quantification and identification of aldehydes and ketones in biological samples.

    Science.gov (United States)

    Siegel, David; Meinema, Anne C; Permentier, Hjalmar; Hopfgartner, Gérard; Bischoff, Rainer

    2014-05-20

    The identification of unknown compounds remains to be a bottleneck of mass spectrometry (MS)-based metabolomics screening experiments. Here, we present a novel approach which facilitates the identification and quantification of analytes containing aldehyde and ketone groups in biological samples by adding chemical information to MS data. Our strategy is based on rapid autosampler-in-needle-derivatization with p-toluenesulfonylhydrazine (TSH). The resulting TSH-hydrazones are separated by ultrahigh-performance liquid chromatography (UHPLC) and detected by electrospray ionization-quadrupole-time-of-flight (ESI-QqTOF) mass spectrometry using a SWATH (Sequential Window Acquisition of all Theoretical Fragment-Ion Spectra) data-independent high-resolution mass spectrometry (HR-MS) approach. Derivatization makes small, poorly ionizable or retained analytes amenable to reversed phase chromatography and electrospray ionization in both polarities. Negatively charged TSH-hydrazone ions furthermore show a simple and predictable fragmentation pattern upon collision induced dissociation, which enables the chemo-selective screening for unknown aldehydes and ketones via a signature fragment ion (m/z 155.0172). By means of SWATH, targeted and nontargeted application scenarios of the suggested derivatization route are enabled in the frame of a single UHPLC-ESI-QqTOF-HR-MS workflow. The method's ability to simultaneously quantify and identify molecules containing aldehyde and ketone groups is demonstrated using 61 target analytes from various compound classes and a (13)C labeled yeast matrix. The identification of unknowns in biological samples is detailed using the example of indole-3-acetaldehyde. PMID:24745975

  10. Determination of total mercury and methylmercury in biological samples by photochemical vapor generation

    Energy Technology Data Exchange (ETDEWEB)

    Vieira, Mariana A.; Ribeiro, Anderson S.; Curtius, Adilson J. [Universidade Federal de Santa Catarina, Departamento de Quimica, Florianopolis, SC (Brazil); Sturgeon, Ralph E. [National Research Council Canada, Institute for National Measurement Standards, Ottawa, ON (Canada)

    2007-06-15

    Cold vapor atomic absorption spectrometry (CV-AAS) based on photochemical reduction by exposure to UV radiation is described for the determination of methylmercury and total mercury in biological samples. Two approaches were investigated: (a) tissues were digested in either formic acid or tetramethylammonium hydroxide (TMAH), and total mercury was determined following reduction of both species by exposure of the solution to UV irradiation; (b) tissues were solubilized in TMAH, diluted to a final concentration of 0.125% m/v TMAH by addition of 10% v/v acetic acid and CH{sub 3}Hg{sup +} was selectively quantitated, or the initial digests were diluted to 0.125% m/v TMAH by addition of deionized water, adjusted to pH 0.3 by addition of HCl and CH{sub 3}Hg{sup +} was selectively quantitated. For each case, the optimum conditions for photochemical vapor generation (photo-CVG) were investigated. The photochemical reduction efficiency was estimated to be {proportional_to}95% by comparing the response with traditional SnCl{sub 2} chemical reduction. The method was validated by analysis of several biological Certified Reference Materials, DORM-1, DORM-2, DOLT-2 and DOLT-3, using calibration against aqueous solutions of Hg{sup 2+}; results showed good agreement with the certified values for total and methylmercury in all cases. Limits of detection of 6 ng/g for total mercury using formic acid, 8 ng/g for total mercury and 10 ng/g for methylmercury using TMAH were obtained. The proposed methodology is sensitive, simple and inexpensive, and promotes ''green'' chemistry. The potential for application to other sample types and analytes is evident. (orig.)

  11. Determination of gadolinium-based MRI contrast agents in biological and environmental samples: A review

    Energy Technology Data Exchange (ETDEWEB)

    Telgmann, Lena [University of Münster, Institute of Inorganic and Analytical Chemistry, Münster (Germany); Sperling, Michael [University of Münster, Institute of Inorganic and Analytical Chemistry, Münster (Germany); European Virtual Institute for Speciation Analysis (EVISA), Münster (Germany); Karst, Uwe, E-mail: uk@uni-muenster.de [University of Münster, Institute of Inorganic and Analytical Chemistry, Münster (Germany)

    2013-02-18

    Highlights: ► All major methods for the analysis of Gd-based MRI contrast agents are discussed. ► Biological and environmental samples are covered. ► Pharmacokinetics and species transformation can be investigated. ► The figures of merit as limit of detection and analysis time are described. -- Abstract: The development of analytical methods and strategies to determine gadolinium and its complexes in biological and environmental matrices is evaluated in this review. Gadolinium (Gd) chelates are employed as contrast agents for magnetic resonance imaging (MRI) since the 1980s. In general they were considered as safe and well-tolerated, when in 2006, the disease nephrogenic systemic fibrosis (NSF) was connected to the administration of MRI contrast agents based on Gd. Pathogenesis and etiology of NSF are yet unclear and called for the development of several analytical methods to obtain elucidation in this field. Determination of Gd complex stability in vitro and in vivo, as well as the quantification of Gd in body fluids like blood and urine was carried out. Separation of the Gd chelates was achieved with high performance liquid chromatography (HPLC) and capillary electrophoresis (CE). For detection, various methods were employed, including UV–vis absorbance and fluorescence spectroscopy, electrospray ionization mass spectrometry (ESI-MS) and inductively coupled plasma mass spectrometry (ICP-MS). A second challenge for analysts was the discovery of high concentrations of anthropogenic Gd in surface waters draining populated areas. The source could soon be determined to be the increasing administration of Gd complexes during MRI examinations. Identification and quantification of the contrast agents was carried out in various surface and groundwater samples to determine the behavior and fate of the Gd chelates in the environment. The improvement of limits of detection (LOD) and limits of quantification (LOQ) was and still is the goal of past and ongoing

  12. Microscopic linear liquid streams in vacuum: Injection of solvated biological samples into X-ray free electron lasers

    International Nuclear Information System (INIS)

    Microscopic linear liquid free-streams offer a means of gently delivering biological samples into a probe beam in vacuum while maintaining the sample species in a fully solvated state. By employing gas dynamic forces to form the microscopic liquid stream (as opposed to a conventional solid-walled convergent nozzle), liquid free-streams down to 300 nm diameter have been generated. Such 'Gas Dynamic Virtual Nozzles' (GDVN) are ideally suited to injecting complex biological species into an X-ray Free Electron Laser (XFEL) to determine the structure of the biological species via Serial Femtosecond Crystallography (SFX). GDVN injector technology developed for this purpose is described.

  13. Introduction of a cryosectioning-ToF-SIMS instrument for analysis of non-dehydrated biological samples

    Science.gov (United States)

    Möller, J.; Beumer, A.; Lipinsky, D.; Arlinghaus, H. F.

    2006-07-01

    Tof-SIMS and laser-SNMS are becoming increasingly important tools for analysing the elemental and molecular distribution in biological samples. We have developed the prototype of an in-vacuum cryosectioning instrument directly attached to a ToF-SIMS/laser-SNMS instrument, which allows preparing and analyzing frozen non-dehydrated biological samples. Due to unavoidable effects during the handling, storing, and preparation of frozen samples, even inside the vacuum, it must be ensured that the analyzed surface is from the sample and not a preparation artefact. To this effect, a model structure, similar to the biological samples and with a defined chemical composition, was analyzed under varying thermal treatment before and during analysis, respectively, in order to identify a balance between evaporating and subliming adsorbed materials and the effect of freeze-drying on the measured signal.

  14. Definition of nearly zero-energy building requirements based on a large building sample

    International Nuclear Information System (INIS)

    According to the recast of the Energy Performance Building Directive, Member States must give an exact definition for nearly zero-energy buildings to be introduced from 2018/2020. The requirement system stipulating the sustainable development of the building sector is usually based on the analysis of a few reference buildings, combining energy efficiency measures and HVAC systems. The risk of this method is that depending on the assumptions either the requirements do not provide sufficient incentives for energy saving measures and renewables or the requirements cannot be fulfilled with rational solutions in many cases. Our method is based on the artificial generation of a large building sample, where the buildings are defined by geometric and other parameters. Due to the large number of combinations, the effect of many variables appear in the results, with the deviations reflecting the sensitivity of the energy balance. The requirements are set based on some fundamental considerations and the statistical analysis of the sample. The method is demonstrated on the example of setting the requirements for residential buildings in Hungary. The proposed requirements are validated against the common European targets. The suggested method is suitable for developing building energy regulation threshold values, certification schemes or benchmarking values. - Highlights: • We analyse the European nearly zero-energy building definition. • We present a method for setting requirements based on a large building sample. • We demonstrate the method for residential buildings in Hungary. • We compare the results with the European targets

  15. Speciation of trace elements in biological samples by nuclear analytical and related techniques coupled with chemical and biochemical separation

    International Nuclear Information System (INIS)

    In the past, most analytical problems relating to biological systems were addressed by measuring the total concentrations of elements. Now there is increasing interest of the importance of their chemical forms, in which an element is present in biological systems, e.g., the oxidation state, the binding state with macromolecules, or even the molecular structure. The biological effects of chromium, which is classified as an essential nutrient, are dependent upon its oxidation. state. In general, trivalent chromium is biochemically active, whereas hexavalent chromium is considered to be toxic. Mercury is one of serious environmental persistent pollutants. However, organic forms of mercury are known to possess much higher toxicity than inorganic mercury. Therefore, information on speciation is critically required in order to better understanding of their bioavailability, metabolism, transformation, and toxicity in vivo. Recently, chemical speciation of selenium, mercury, copper, zinc, iron, and so on, has been investigated by INAA, ICP-MS, XRF, EXAFS and related techniques combined with chemical and biochemical separation (extraction, chromatography, gel electrophoresis, etc.). INAA, XRF, and ICP-MS have superior advantages in aspect of multielemental analysis with high accuracy and sensitivity, which render the possibility of analyzing various elements of interest simultaneously. These offline or online techniques have been flexibly applied to different biological matrixes, such as human hair, serum, urine, various tissues and organs in our researches. In addition, EXAFS provides structural information about the moiety of metal centers up to a distance of approximately 4-5 Anstrom. For instance, hepatocellular carcinoma (HCC) is one of the most common cancers worldwide. Imbalance of elements, such as Se, Zn, Fe, Cu, Cd, Ca, etc., has been found in the whole blood or serum of patients with HCC. We found that the profiles of Se, Cd, Fe, Zn and Cu-containing proteins

  16. Study on the determination of palladium in biological samples by the method of neutron activation analysis

    International Nuclear Information System (INIS)

    Palladium is one of platinum group elements present in the nature at very low concentrations. However with the use of this element in the automobile catalyzers Pd became a new pollutant. Besides, Pd has been studied in the preparation of new antitumour drugs. Consequently, there is a need to determine Pd concentrations in biological and environmental samples. This study presents palladium results obtained in the analysis of biological samples and reference materials using instrumental thermal and epithermal neutron activation analysis (INAA and ENAA). The solvent extraction and solid phase extraction separation methods were also applied before ENAA. The samples analyzed in this study were, reference material BCR 723 - Palladium, Platinum and Rhodium in road dust, CCQM-P63 automotive catalyst material of the Proficiency Test and bovine tissue samples containing palladium prepared in the laboratory. Samples and palladium synthetic standard were irradiated at the IEA-R1 nuclear research reactor under thermal neutron flux of about 4 x 10 12 n cm-2 s-1, during a period of 4 and 16 h for INAA and ENAA, respectively. The induced gamma activity of 109Pd to the sample and standard was measured using a hyper pure Ge detector coupled to a gamma ray spectrometer. The palladium concentration was calculated by comparative method. The gamma ray energy of 109Pd radioisotope measured was of 88.0 keV, located in a spectrum region of low energy where occurs the interference of X rays, 'Bremsstrahlung' radiations, as well as Compton effect of 24Na. The pre-separation of palladium from interfering elements by solvent extraction was performed using dimethylglyoxime complexant and chloroform as diluent. In the case of the pre separation procedure using solid reversed phase column, the palladium was retained using N,N-diethyl-N'-benzoyl thiourea complexant and eluted using ethanol. Aliquots of the resulting solutions from the pre-separations, free of interfering elements, were transferred

  17. Applying a low energy HPGe detector gamma ray spectrometric technique for the evaluation of Pu/Am ratio in biological samples

    International Nuclear Information System (INIS)

    The estimation of Pu/241Am ratio in the biological samples is an important input for the assessment of internal dose received by the workers. The radiochemical separation of Pu isotopes and 241Am in a sample followed by alpha spectrometry is a widely used technique for the determination of Pu/241Am ratio. However, this method is time consuming and many times quick estimation is required. In this work, Pu/241Am ratio in the biological sample was estimated with HPGe detector based measurements using gamma/X-rays emitted by these radionuclides. These results were compared with those obtained from alpha spectroscopy of sample after radiochemical analysis and found to be in good agreement. - Highlights: • High resolution gamma ray spectroscopy technique with low energy HPGe detector is used for the measurement of Pu isotopes and 241Am in biological samples. • Results obtained with gamma ray spectroscopy compared well with the results obtained from radiochemical analysis of sample followed by α-spectroscopy. • Results of this study will be useful for assessment and medical management of Pu/241Am embedded in tissue of workers

  18. A user-friendly robotic sample preparation program for fully automated biological sample pipetting and dilution to benefit the regulated bioanalysis.

    Science.gov (United States)

    Jiang, Hao; Ouyang, Zheng; Zeng, Jianing; Yuan, Long; Zheng, Naiyu; Jemal, Mohammed; Arnold, Mark E

    2012-06-01

    Biological sample dilution is a rate-limiting step in bioanalytical sample preparation when the concentrations of samples are beyond standard curve ranges, especially when multiple dilution factors are needed in an analytical run. We have developed and validated a Microsoft Excel-based robotic sample preparation program (RSPP) that automatically transforms Watson worklist sample information (identification, sequence and dilution factor) to comma-separated value (CSV) files. The Freedom EVO liquid handler software imports and transforms the CSV files to executable worklists (.gwl files), allowing the robot to perform sample dilutions at variable dilution factors. The dynamic dilution range is 1- to 1000-fold and divided into three dilution steps: 1- to 10-, 11- to 100-, and 101- to 1000-fold. The whole process, including pipetting samples, diluting samples, and adding internal standard(s), is accomplished within 1 h for two racks of samples (96 samples/rack). This platform also supports online sample extraction (liquid-liquid extraction, solid-phase extraction, protein precipitation, etc.) using 96 multichannel arms. This fully automated and validated sample dilution and preparation process has been applied to several drug development programs. The results demonstrate that application of the RSPP for fully automated sample processing is efficient and rugged. The RSPP not only saved more than 50% of the time in sample pipetting and dilution but also reduced human errors. The generated bioanalytical data are accurate and precise; therefore, this application can be used in regulated bioanalysis. PMID:22357562

  19. Assessment of DDT levels in selected environmental media and biological samples from Mexico and Central America.

    Science.gov (United States)

    Pérez-Maldonado, Iván N; Trejo, Antonio; Ruepert, Clemens; Jovel, Reyna del Carmen; Méndez, Mónica Patricia; Ferrari, Mirtha; Saballos-Sobalvarro, Emilio; Alexander, Carlos; Yáñez-Estrada, Leticia; Lopez, Dania; Henao, Samuel; Pinto, Emilio R; Díaz-Barriga, Fernando

    2010-03-01

    Taking into account the environmental persistence and the toxicity of DDT, the Pan American Health Organization (PAHO) organized a surveillance program in Mesoamerica which included the detection of residual DDT in environmental (soil) and biological samples (fish tissue and children's blood). This program was carried out in communities from Mexico, Guatemala, El Salvador, Honduras, Nicaragua, Costa Rica and Panama. This paper presents the first report of that program. As expected, the results show that the levels for [summation operator] DDT in soil (outdoor or indoor) and fish samples in the majority of the locations studied are below guidelines. However, in some locations, we found children with high concentrations of DDT as in Mexico (mean level 50.2 ng/mL). Furthermore, in some communities and for some matrices, the DDT/DDE quotient is higher than one and this may reflect a recent DDT exposure. Therefore, more efforts are needed to avoid exposure and to prevent the reintroduction of DDT into the region. In this regard it is important to know that under the surveillance of PAHO and with the support of UNEP, a regional program in Mesoamerica for the collection and disposal of DDT and other POPs stockpiles is in progress. PMID:20092871

  20. Synchrotron-based X-ray fluorescence, imaging and elemental mapping from biological samples

    Indian Academy of Sciences (India)

    D V Rao; M Swapna; R Cesareo; A Brunetti; T Akatsuka; T Yuasa; T Takeda; G E Gigante

    2011-02-01

    The present study utilized the new hard X-ray microspectroscopy beamline facility, X27A, available at NSLS, BNL, USA, for elemental mapping. This facility provided the primary beam in a small spot of the order of ∼ 10 m, for focussing. With this spatial resolution and high flux throughput, the synchrotron-based X-ray fluorescent intensities for Mn, Fe, Zn, Cr, Ti and Cu were measured using a liquid-nitrogen-cooled 13-element energy-dispersive high-purity germanium detector. The sample is scanned in a `step-and-repeat’ mode for fast elemental mapping measurements and generated elemental maps at 8, 10 and 12 keV, from a small animal shell (snail). The accumulated trace elements, from these biological samples, in small areas have been identified. Analysis of the small areas will be better suited to establish the physiology of metals in specific structures like small animal shell and the distribution of other elements.

  1. 3D surface scan of biological samples with a Push-broom Imaging Spectrometer

    Science.gov (United States)

    Yao, Haibo; Kincaid, Russell; Hruska, Zuzana; Brown, Robert L.; Bhatnagar, Deepak; Cleveland, Thomas E.

    2013-08-01

    The food industry is always on the lookout for sensing technologies for rapid and nondestructive inspection of food products. Hyperspectral imaging technology integrates both imaging and spectroscopy into unique imaging sensors. Its application for food safety and quality inspection has made significant progress in recent years. Specifically, hyperspectral imaging has shown its potential for surface contamination detection in many food related applications. Most existing hyperspectral imaging systems use pushbroom scanning which is generally used for flat surface inspection. In some applications it is desirable to be able to acquire hyperspectral images on circular objects such as corn ears, apples, and cucumbers. Past research describes inspection systems that examine all surfaces of individual objects. Most of these systems did not employ hyperspectral imaging. These systems typically utilized a roller to rotate an object, such as an apple. During apple rotation, the camera took multiple images in order to cover the complete surface of the apple. The acquired image data lacked the spectral component present in a hyperspectral image. This paper discusses the development of a hyperspectral imaging system for a 3-D surface scan of biological samples. The new instrument is based on a pushbroom hyperspectral line scanner using a rotational stage to turn the sample. The system is suitable for whole surface hyperspectral imaging of circular objects. In addition to its value to the food industry, the system could be useful for other applications involving 3-D surface inspection.

  2. Methods of biological fluids sample preparation - biogenic amines, methylxanthines, water-soluble vitamins.

    Science.gov (United States)

    Płonka, Joanna

    2015-01-01

    In recent years demands on the amount of information that can be obtained from the analysis of a single sample have increased. For time and economic reasons it is necessary to examine at the same time larger number of compounds, and compounds from different groups. This can best be seen in such areas as clinical analysis. In many diseases, the best results for patients are obtained when treatment fits the individual characteristics of the patient. Dosage monitoring is important at the beginning of therapy and in the full process of treatment. In the treatment of many diseases biogenic amines (dopamine, serotonin) and methylxanthines (theophylline, theobromine, caffeine) play an important role. They are used as drugs separately or in combination with others to support and strengthen the action of other drugs - for example, the combination of caffeine and paracetamol. Vitamin supplementation may be also an integral part of the treatment process. Specification of complete sample preparation parameters for extraction of the above compounds from biological matrices has been reviewed. Particular attention was given to the preparation stage and extraction methods. This review provides universal guidance on establishing a common procedures across laboratories to facilitate the preparation and analysis of all discussed compounds. PMID:25381720

  3. Biological Monitoring of Human Exposure to Neonicotinoids Using Urine Samples, and Neonicotinoid Excretion Kinetics.

    Directory of Open Access Journals (Sweden)

    Kouji H Harada

    Full Text Available Neonicotinoids, which are novel pesticides, have entered into usage around the world because they are selectively toxic to arthropods and relatively non-toxic to vertebrates. It has been suggested that several neonicotinoids cause neurodevelopmental toxicity in mammals. The aim was to establish the relationship between oral intake and urinary excretion of neonicotinoids by humans to facilitate biological monitoring, and to estimate dietary neonicotinoid intakes by Japanese adults.Deuterium-labeled neonicotinoid (acetamiprid, clothianidin, dinotefuran, and imidacloprid microdoses were orally ingested by nine healthy adults, and 24 h pooled urine samples were collected for 4 consecutive days after dosing. The excretion kinetics were modeled using one- and two-compartment models, then validated in a non-deuterium-labeled neonicotinoid microdose study involving 12 healthy adults. Increased urinary concentrations of labeled neonicotinoids were observed after dosing. Clothianidin was recovered unchanged within 3 days, and most dinotefuran was recovered unchanged within 1 day. Around 10% of the imidacloprid dose was excreted unchanged. Most of the acetamiprid was metabolized to desmethyl-acetamiprid. Spot urine samples from 373 Japanese adults were analyzed for neonicotinoids, and daily intakes were estimated. The estimated average daily intake of these neonicotinoids was 0.53-3.66 μg/day. The highest intake of any of the neonicotinoids in the study population was 64.5 μg/day for dinotefuran, and this was <1% of the acceptable daily intake.

  4. Determination of fluorine in environmental and biological samples by neutron and photon activation analysis

    International Nuclear Information System (INIS)

    In NAA, two analytical reactions, viz. 19F(n,γ)20F (T(1/2) =11.0 s, E(gamma) =1633.6 keV) and 19F(n,p)19O (T(1/2) =26.9 s, E(gamma) =197.1 keV) with thermal and fast neutrons, respectively, can be used. Due to the short half-lives of the activation products, only non-destructive, instrumental NAA (INAA) is feasible. Unfortunately, neither of the analytical reactions is interference-free: the reaction 23Na(n,α)20F with fast neutrons interferes with the former, the reaction 18O(n,γ)19O with thermal neutrons interferes with the latter. The interference free detection limits for irradiation of several types of biological materials at thermal and fast neutron fluency rates of 8.1013 cm-2 s-1 and 2.1013 cm-2 s -1, respectively, are in the range of 0.3 to 2 μg g-1 for both reactions. The actual detection limits for biological samples, however, are significantly higher, at least by one order of magnitude, due to the above interferences. In addition, the detection limit of the 19F(n,γ)20F reaction is strongly influenced by the Al content, particularly in environmental samples, due to the overwhelming activity of 28Al created even after a very short irradiation (10 s). Thus, fluorine can usually be determined in this type of samples at levels of several hundreds to thousands of μg g-1. The pseudocyclic mode of INAA improves the detection limit only slightly - by a factor of 2 after four cycles, by a factor of 3.2 after ten cycles, etc. The determination of fluorine by PAA is based on the reaction 19F(γ,n)18F (T(1/2) = 1.83 h, E(gamma) = 511.0 keV) that is free from nuclear interferences for irradiation with up to 20-MeV bremsstrahlung. In contrast to NAA, radiochemical separation is mandatory for low-level assay of fluorine by PAA because the radionuclide 18F is a pure positron emitter. Therefore, a radiochemical PAA procedure (RPAA) was developed and tested for analysis of biological materials. It is based on alkaline-oxidative fusion with Na2O2 + NaOH followed by

  5. Characterisation of radiation field for irradiation of biological samples at nuclear reactor-comparison of twin detector and recombination methods

    International Nuclear Information System (INIS)

    Central Laboratory for Radiological Protection is involved in achieving scientific project on biological dosimetry. The project includes irradiation of blood samples in radiation fields of nuclear reactor. A simple facility for irradiation of biological samples has been prepared at horizontal channel of the nuclear reactor MARIA in NCBJ in Poland. The radiation field, composed mainly of gamma radiation and thermal neutrons, has been characterised in terms of tissue kerma using twin-detector technique and recombination chambers. Radiobiological measurements in neutron radiation fields always should be accompanied with careful dosimetric measurement because of large variations in composition and neutron energy. In the case of measurements described here, the main problem was the requirement of precise determination of neutron absorbed dose. It was decided to use two measuring methods-twin-detector and recombination method, both based on the use of ionisation chambers. The application of the same type of detectors greatly simplified and shortened the measuring campaign. Total kerma rate was determined with the same chamber for both methods, whereas the determination of?γ is independent and the measured values could be compared for cross-check of the results. The use of combined recombination method using concepts of RMM and RIQ appeared to be very useful. The value of RIQ for neutrons alone was additionally determined and can be used in further evaluation of radiobiological data. Time needed for the determination of saturation curve makes it possible to observe stability of the beam. It was concluded that the neutron kerma rate was high enough to perform radiobiological irradiations. Stability of the beam was very good and continuous monitoring of the beam intensity was practically needed only for the case of unexpected changes in the reactor operation. (authors)

  6. Phosphorus in biological standards and samples by thermal neutron irradiation and β-counting

    International Nuclear Information System (INIS)

    A nondestructive NAA method based on the reaction 31P(n,γ)32P (T1/2 = 14.23 d) has been developed where the product nucleus, a pure β-emitter with end point energy 1.71 MeV is measured by using an end window G.M counter and an Al filter of 27 mg x cm-2. 32P was identified by measuring Eβ using Feather's analysis and its half-life was found to be 15.3±0.2 days in standard reference materials (SRMs) and samples. For most reference materials (RMs) from NIST (USA) and IAEA (Vienna), our values agree within ±5% of the certified values. A variety of biological samples have also been analyzed and our values are in the range; medicinal herbs (n 43), 0.29-5.23 mg/g; bhasmas (n = 19), 0.09-51.4 mg/g; vegetables (n = 8), 1.85-5.73 mg/g; lentils (n = 6), 2.1-5.5 mg/g; flours (n = 6), 1.3-3.3 mg/g; vegetarian diet (n = 5), 2.41-2.90 mg/g; fish (n = 43), 3.61-36.8 mg/g; human and animal milk (n = 6), 1.24-7.95 mg/g; commercial milk powders (n = 14), 2.76-11.9 mg/g; water from various sources (n = 14), 1-417 μg/l; human and animal blood (n = 9), 1.00-15.0 mg/g; cancerous and healthy breast tissue (n = 60), 1.00-8.63 mg/g; human hair (n = 43), 0.12-5.81 mg/g, where n is the number of samples analyzed. The method is simple, fast, and nondestructive and provides data within ±5% error limit with a detection limit of 0.1 mg/g. (author)

  7. Decommissioning samples from the Ft. Lewis, WA, solvent refined coal pilot plant: chemical analysis and biological testing

    Energy Technology Data Exchange (ETDEWEB)

    Weimer, W.C.; Wright, C.W.

    1985-10-01

    This report presents the results from chemical analyses and limited biological assays of three sets of samples from the Ft. Lewis, WA solvent refined coal (SRC) pilot plant. The samples were collected during the process of decommissioning this facility. Chemical composition was determined for chemical class fractions of the samples by using high-resolution gas chromatography (GC), high-resolution GC/mass spectrometry (MS) and high-resolution MS. Biological activity was measuring using both the histidine reversion microbial mutagenicity assay with Salmonella typhimurium, TA98 and an initiation/promotion mouse-skin tumorigenicity assay. 19 refs., 7 figs., 27 tabs.

  8. The determination of americium, curium and californium in biological samples by combined solvent extraction-liquid scintillation counting

    International Nuclear Information System (INIS)

    A method has been developed to extract Am, Cm and Cf from ashed biological samples dissolved in 8 M LiN03-10-2 M HN03 into a liquid/scintillation cocktail. This new method reduces tissue and instrument background and allows use of a larger sample for analysis than when using a commercial gelling cocktail. The extractant cocktail is 20% N,N,N-trioctyl-N-methylammonium chloride dissolved in toluene containing the scintillators p-terphenyl and 1,4-bis-2-(5-phenyl-oxazolyl)-benzene. Several different types of biological samples were analyzed and radionuclide recoveries greater than 90% were obtained in all cases. (author)

  9. In-focus electron microscopy of frozen-hydrated biological samples with a Boersch phase plate

    Energy Technology Data Exchange (ETDEWEB)

    Barton, B.; Rhinow, D.; Walter, A.; Schroeder, R. [Max Planck Institute of Biophysics, Max-von-Laue Str. 3, 60438 Frankfurt am Main (Germany); Benner, G.; Majorovits, E.; Matijevic, M.; Niebel, H. [Carl Zeiss NTS GmbH, D-73447 Oberkochen (Germany); Mueller, H.; Haider, M. [CEOS GmbH, Englerstr. 26, 69126 Heidleberg (Germany); Lacher, M.; Schmitz, S.; Holik, P. [Caesar Research Center, Ludwig-Erhard-Allee 2, D-53175 Bonn (Germany); Kuehlbrandt, W., E-mail: werner.kuehlbrandt@mpibp-frankfurt.mpg.de [Max Planck Institute of Biophysics, Max-von-Laue Str. 3, 60438 Frankfurt am Main (Germany)

    2011-12-15

    We report the implementation of an electrostatic Einzel lens (Boersch) phase plate in a prototype transmission electron microscope dedicated to aberration-corrected cryo-EM. The combination of phase plate, C{sub s} corrector and Diffraction Magnification Unit (DMU) as a new electron-optical element ensures minimal information loss due to obstruction by the phase plate and enables in-focus phase contrast imaging of large macromolecular assemblies. As no defocussing is necessary and the spherical aberration is corrected, maximal, non-oscillating phase contrast transfer can be achieved up to the information limit of the instrument. A microchip produced by a scalable micro-fabrication process has 10 phase plates, which are positioned in a conjugate, magnified diffraction plane generated by the DMU. Phase plates remained fully functional for weeks or months. The large distance between phase plate and the cryo sample permits the use of an effective anti-contaminator, resulting in ice contamination rates of <0.6 nm/h at the specimen. Maximal in-focus phase contrast was obtained by applying voltages between 80 and 700 mV to the phase plate electrode. The phase plate allows for in-focus imaging of biological objects with a signal-to-noise of 5-10 at a resolution of 2-3 nm, as demonstrated for frozen-hydrated virus particles and purple membrane at liquid-nitrogen temperature. -- Highlights: Black-Right-Pointing-Pointer We implement an electrostatic Boersch phase plate into a dedicated prototypical TEM. Black-Right-Pointing-Pointer Phase contrast aberration-corrected electron microscope (PACEM) includes a diffraction magnification unit (DMU). Black-Right-Pointing-Pointer DMU minimizes obstruction of low spatial frequencies by the phase plate. Black-Right-Pointing-Pointer In-focus phase contrast generation is demonstrated for frozen-hydrated biological specimens.

  10. Supercritical fluid carbon dioxide extraction and liquid chromatographic separation with electrochemical detection of methylmercury from biological samples

    Science.gov (United States)

    Simon, N.S.

    1997-01-01

    Using the coupled methods presented in this paper, methylmercury can be accurately and rapidly extracted from biological samples by modified supercritical fluid carbon dioxide and quantitated using liquid chromatography with reductive electrochemical detection. Supercritical fluid carbon dioxide modified with methanol effectively extracts underivatized methylmercury from certified reference materials Dorm-1 (dogfish muscle) and Dolt-2 (dogfish liver). Calcium chloride and water, with a ratio of 5:2 (by weight), provide the acid environment required for extracting methylmercury from sample matrices. Methylmercury chloride is separated from other organomercury chloride compounds using HPLC. The acidic eluent, containing 0.06 mol L-1 NaCl, insures the presence of methylmercury chloride and facilitates the reduction of mercury on a glassy carbon electrode. If dual glassy carbon electrodes are used, a positive peak is observed at -0.65 to -0.70 V and a negative peak is observed at -0.90V with the organomercury compounds that were tested. The practical detection limit for methylmercury is 5 X 10-8 mol L-1 (1 X 10-12 tool injected) when a 20 ??L injection loop is used.

  11. Sample preparation of biological macromolecular assemblies for the determination of high-resolution structures by cryo-electron microscopy.

    Science.gov (United States)

    Stark, Holger; Chari, Ashwin

    2016-02-01

    Single particle cryo-EM has recently developed into a powerful tool to determine the 3D structure of macromolecular complexes at near-atomic resolution, which allows structural biologists to build atomic models of proteins. All technical aspects of cryo-EM technology have been considerably improved over the last two decades, including electron microscopic hardware, image processing software and the ever growing speed of computers. This leads to a more widespread use of the technique, and it can be anticipated that further automation of electron microscopes and image processing tools will soon fully shift the focus away from the technological aspects, onto biological questions that can be answered. In single particle cryo-EM, no crystals of a macromolecule are required. In contrast to X-ray crystallography, this significantly facilitates structure determination by cryo-EM. Nevertheless, a relatively high level of biochemical control is still essential to obtain high-resolution structures by cryo-EM, and it can be anticipated that the success of the cryo-EM technology goes hand in hand with further developments of sample purification and preparation techniques. This will allow routine high-resolution structure determination of the many macromolecular complexes of the cell that until now represent evasive targets for X-ray crystallographers. Here we discuss the various biochemical tools that are currently available and the existing sample purification and preparation techniques for cryo-EM grid preparation that are needed to obtain high-resolution images for structure determination. PMID:26671943

  12. SAMPLING AND CALIBRATION REQUIREMENTS FOR OPTICAL REFLECTANCE SOIL PROPERTY SENSORS FOR KOREAN PADDY SOILS

    Science.gov (United States)

    Optical diffuse reflectance sensing has potential for rapid and reliable on-site estimation of soil properties. For good results, proper calibration to measured soil properties is required. One issue is whether it is necessary to develop calibrations using samples from the specific area or areas (e....

  13. Technical assessment of compliance with workplace air sampling requirements in the 300 Area

    International Nuclear Information System (INIS)

    The purpose of this Technical Work Document is to satisfy HSRCM-1, the ''Hanford Site Radiological Control Manual.'' Article 551.4 of that manual states a requirement for a documented study of facility workplace air sampling programs (WPAS). This first revision of the original Supporting Document covers the period from January 1, 1995 to December 31, 1995. HSRCM-1 is the primary guidance for radiological control at Westinghouse Hanford Company (WHC). It was written to implement DOE/EH-0256T ''US Department of Energy Radiological Control Manual'' as it applies to programs at Hanford. As such, it complies with Title 10, Part 835 of the Code of Federal Regulations. There are also several Department of Energy (DOE) Orders, national consensus standards, and reports that provide criteria, standards, and requirements for workplace air sampling programs. This document provides a summary of these, as they apply to WHC facility workplace air sampling programs. This document also provides an evaluation of the compliance of 300 Areas' workplace air sampling program to the criteria, standards, and requirements and documents compliance with the requirements where appropriate. Where necessary, it also indicates changes needed to bring specific locations into compliance. The areas evaluated were the 340 Facility, the Advanced Reactor Operations Division Facilities, the N Reactor Fuels Supply Facility, and The Geotechnical Engineering Laboratory

  14. Technical assessment of workplace air sampling requirements at tank farm facilities. Revision 2

    International Nuclear Information System (INIS)

    Tank Farm facilities compliance with the workplace air sampling (WPAS) program has been assessed. Requirements bases for determining compliance and recommendations are included. In the current condition all buildings are in compliance with the WPAS program. This document also supersedes WHC-SD-SQA-TA-20012, revision 0

  15. Sample Size Requirements in Single- and Multiphase Growth Mixture Models: A Monte Carlo Simulation Study

    Science.gov (United States)

    Kim, Su-Young

    2012-01-01

    Just as growth mixture models are useful with single-phase longitudinal data, multiphase growth mixture models can be used with multiple-phase longitudinal data. One of the practically important issues in single- and multiphase growth mixture models is the sample size requirements for accurate estimation. In a Monte Carlo simulation study, the…

  16. Biology and thermal requirements to Trichogramma spp. selection for Ecdytolopha aurantiana control

    International Nuclear Information System (INIS)

    The purpose of this work was to evaluate the potential of Trichogramma atopovirilia Oatman and Platner, 1983 and T. pretiosum Riley, 1879 as agents of control of Ecdytolopha aurantiana (Lima, 1927) (Lepidoptera: Tortricidae), an important Citrus pest in Sao Paulo State (South-East Brazil). In order to provide subsidies to programs of biological control with these parasitoids, studies of biology in different temperatures, thermal requirements and parasitism capacity were carried out. The temperatures (18, 20, 22, 25, 28, 30, and 32 deg C) did not affect the sex ratio, however, female longevity of both species was higher at 22 and 25 deg C. The temperature of 25 deg C tended to be more suitable to both emergency rate and female longevity. The egg-adult period for both Trichogramma species was inversely proportional to temperature. The thermal requirements of the two species were very close, about 108 DD (degree days). Neither the natural rearing host, E. aurantiana, nor the alternative host Anagasta kuehniella (Zeller, 1879) (Lepidoptera, Pyralidae), affected the number of parasitized eggs per Trichogramma female. The parasitism rate and the number of emerged adults per egg on E. aurantiana eggs were higher than on A. kuehniella eggs. However, the emergency rate was higher when the parasitoids were reared on A. kuehniella eggs. Both Trichogramma species could be tested in the field for citrus fruit borer control. The thermal requirements and the parasitism capacity also could be good parameters for selection of Trichogramma species/strains. (author)

  17. Analysis of inorganic elements in biological samples of C57BL/6J mouse strain using INAA

    Energy Technology Data Exchange (ETDEWEB)

    Metairon, Sabrina; Zamboni, Cibele B.; Suzuki, Miriam F.; Kovacs, Luciana, E-mail: metairon@usp.br, E-mail: czamboni@ipen.br, E-mail: mfsuzuki@ipen.br, E-mail: lukovacs@gmail.com [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil); Bueno Junior, Carlos R., E-mail: carmao11@yahoo.com.br [Universidade de Sao Paulo (IB/USP), Sao Paulo, SP (Brazil). Instituto de Biociencias. Centro de Estudos do Genoma Humano

    2013-07-01

    The research for new medicine, vaccines and other products of interest in health area, for any disease, requires several in vivo tests using animal models on experiments for clinical analysis of actions in organism, focusing on the relation between these and the responses or reactions to their use, allowing or not their use in human being. The present investigation deals with the determination of elements concentration (Ca, Cl, K, Mg and Na) of clinical relevance in kidney and liver of C57BL/6J mice strain using the Instrumental Neutron Activation Analysis technique. Particularly, the C57BL/6J strain is one of the most widely used mice genetically modified for human disease studies. The biological samples were collected from 2 month old adult mice bred in the Biotherium (animal breeding) of UNIFESP (Federal University of Sao Paulo, Brasil) and at Human Genome Research Center (University of Sao Paulo, Brasil) and Biotechnology Center (IPEN, Sao Paulo, Brasil). The measurements were performed in the nuclear reactor IEA-R1 (3.5-4.5MW, pool type) at IPEN. These data will allow researchers to optimize their studies, both in terms of cost and time, by knowing the basal reference values in blood and organs of this strain. Additionally, this analytical procedure meets the needs of the world tendency that emphasizes the requirements to propose alternative methods for clinical research that contribute to animal welfare. (author)

  18. Analytical methods for the quantification of bisphenol A, alkylphenols, phthalate esters, and perfluoronated chemicals in biological samples.

    Science.gov (United States)

    Nakazawa, Hiroyuki; Iwasaki, Yusuke; Ito, Rie

    2014-01-01

    Our modern society has created a large number of chemicals that are used for the production of everyday commodities including toys, food packaging, cosmetic products, and building materials. We enjoy a comfortable and convenient lifestyle with access to these items. In addition, in specialized areas, such as experimental science and various medical fields, laboratory equipment and devices that are manufactured using a wide range of chemical substances are also extensively employed. The association between human exposure to trace hazardous chemicals and an increased incidence of endocrine disease has been recognized. However, the evaluation of human exposure to such endocrine disrupting chemicals is therefore imperative, and the determination of exposure levels requires the analysis of human biological materials, such as blood and urine. To obtain as much information as possible from limited sample sizes, highly sensitive and reliable analytical methods are also required for exposure assessments. The present review focuses on effective analytical methods for the quantification of bisphenol A (BPA), alkylphenols (APs), phthalate esters (PEs), and perfluoronated chemicals (PFCs), which are chemicals used in the production of everyday commodities. Using data obtained from liquid chromatography/mass spectrometry (LC/MS) and LC/MS/MS analyses, assessments of the risks to humans were also presented based on the estimated levels of exposure to PFCs. PMID:24420241

  19. Analysis of inorganic elements in biological samples of C57BL/6J mouse strain using INAA

    International Nuclear Information System (INIS)

    The research for new medicine, vaccines and other products of interest in health area, for any disease, requires several in vivo tests using animal models on experiments for clinical analysis of actions in organism, focusing on the relation between these and the responses or reactions to their use, allowing or not their use in human being. The present investigation deals with the determination of elements concentration (Ca, Cl, K, Mg and Na) of clinical relevance in kidney and liver of C57BL/6J mice strain using the Instrumental Neutron Activation Analysis technique. Particularly, the C57BL/6J strain is one of the most widely used mice genetically modified for human disease studies. The biological samples were collected from 2 month old adult mice bred in the Biotherium (animal breeding) of UNIFESP (Federal University of Sao Paulo, Brasil) and at Human Genome Research Center (University of Sao Paulo, Brasil) and Biotechnology Center (IPEN, Sao Paulo, Brasil). The measurements were performed in the nuclear reactor IEA-R1 (3.5-4.5MW, pool type) at IPEN. These data will allow researchers to optimize their studies, both in terms of cost and time, by knowing the basal reference values in blood and organs of this strain. Additionally, this analytical procedure meets the needs of the world tendency that emphasizes the requirements to propose alternative methods for clinical research that contribute to animal welfare. (author)

  20. A self-contained polymeric cartridge for automated biological sample preparation.

    Science.gov (United States)

    Xu, Guolin; Lee, Daniel Yoke San; Xie, Hong; Chiew, Deon; Hsieh, Tseng-Ming; Ali, Emril Mohamed; Lun Looi, Xing; Li, Mo-Huang; Ying, Jackie Y

    2011-09-01

    Sample preparation is one of the most crucial processes for nucleic acids based disease diagnosis. Several steps are required for nucleic acids extraction, impurity washes, and DNA/RNA elution. Careful sample preparation is vital to the obtaining of reliable diagnosis, especially with low copies of pathogens and cells. This paper describes a low-cost, disposable lab cartridge for automatic sample preparation, which is capable of handling flexible sample volumes of 10 μl to 1 ml. This plastic cartridge contains all the necessary reagents for pathogen and cell lysis, DNA/RNA extraction, impurity washes, DNA/RNA elution and waste processing in a completely sealed cartridge. The entire sample preparation processes are automatically conducted within the cartridge on a desktop unit using a pneumatic fluid manipulation approach. Reagents transportation is achieved with a combination of push and pull forces (with compressed air and vacuum, respectively), which are connected to the pneumatic inlets at the bottom of the cartridge. These pneumatic forces are regulated by pinch valve manifold and two pneumatic syringe pumps within the desktop unit. The performance of this pneumatic reagent delivery method was examined. We have demonstrated the capability of the on-cartridge RNA extraction and cancer-specific gene amplification from 10 copies of MCF-7 breast cancer cells. The on-cartridge DNA recovery efficiency was 54-63%, which was comparable to or better than the conventional manual approach using silica spin column. The lab cartridge would be suitable for integration with lab-chip real-time polymerase chain reaction devices in providing a portable system for decentralized disease diagnosis. PMID:22662036

  1. Data Quality Objectives for Regulatory Requirements for Hazardous and Radioactive Air Emissions Sampling and Analysis

    International Nuclear Information System (INIS)

    This document describes the results of the data quality objective (DQO) process undertaken to define data needs for state and federal requirements associated with toxic, hazardous, and/or radiological air emissions under the jurisdiction of the River Protection Project (RPP). Hereafter, this document is referred to as the Air DQO. The primary drivers for characterization under this DQO are the regulatory requirements pursuant to Washington State regulations, that may require sampling and analysis. The federal regulations concerning air emissions are incorporated into the Washington State regulations. Data needs exist for nonradioactive and radioactive waste constituents and characteristics as identified through the DQO process described in this document. The purpose is to identify current data needs for complying with regulatory drivers for the measurement of air emissions from RPP facilities in support of air permitting. These drivers include best management practices; similar analyses may have more than one regulatory driver. This document should not be used for determining overall compliance with regulations because the regulations are in constant change, and this document may not reflect the latest regulatory requirements. Regulatory requirements are also expected to change as various permits are issued. Data needs require samples for both radionuclides and nonradionuclide analytes of air emissions from tanks and stored waste containers. The collection of data is to support environmental permitting and compliance, not for health and safety issues

  2. Fast screening of ketamine in biological samples based on molecularly imprinted photonic hydrogels

    Energy Technology Data Exchange (ETDEWEB)

    Meng, Liang [Department of Forensic Science, People' s Public Security University of China, Beijing (China); Meng, Pinjia, E-mail: mengpinjia@163.com [Department of Forensic Science, People' s Public Security University of China, Beijing (China); Zhang, Qingqing; Wang, Yanji [Department of Forensic Science, People' s Public Security University of China, Beijing (China)

    2013-04-10

    Graphical abstract: A novel label-free colorimetric chemosensor: with the increase in the concentration of ketamine, the Bragg diffraction peak of MIPHs gradually shifted to the longer wavelength region. Accompanying the peak shift, the color change of MIPHs was also observed obviously: from green to red. Highlights: ► We developed the label-free colorimetric MIPHs for handy and fast screening of ketamine. ► The obvious color change of MIPHs was observed upon ketamine. ► The MIPHs exhibited good sensing abilities in an aqueous environment. ► The sensing mechanisms of the water-compatible MIPHs were investigated. ► The MIPHs were employed to screening ketamine in real biological samples. -- Abstract: A novel label-free colorimetric chemosensor was developed for handy and fast screening of ketamine with high sensitivity and specificity based on molecularly imprinted photonic hydrogels (MIPHs) that combined the colloidal-crystal with molecular imprinting technique. The unique inverse opal arrays with a thin polymer wall in which the imprinted nanocavities of ketamine moleculars distributed allowed high sensitive, quick responsive, specific detection of the target analyte, and good regenerating ability in an aqueous environment. Due to the hierarchical inverse opal structural characteristics, the specific ketamine molecular recognition process can induce obvious swelling of the MIPHs to be directly transferred into visually perceptible optical signal (change in color) which can be detected by the naked eye through Bragg diffractive shifts of ordered macroporous arrays. In order to enhance the recognition ability in aqueous environments, the MIPHs were designed as water-compatible and synthesized in a water–methanol system. The molecular recognition mechanisms were investigated. The proposed MIPHs were successfully employed to screen trace level ketamine in human urine and saliva samples, exhibiting high sensitivity, rapid response, and specificity in the

  3. Nanoparticle sensor for label free detection of swine DNA in mixed biological samples

    International Nuclear Information System (INIS)

    We used 40 ± 5 nm gold nanoparticles (GNPs) as colorimetric sensor to visually detect swine-specific conserved sequence and nucleotide mismatch in PCR-amplified and non-amplified mitochondrial DNA mixtures to authenticate species. Colloidal GNPs changed color from pinkish-red to gray-purple in 2 mM PBS. Visually observed results were clearly reflected by the dramatic reduction of surface plasmon resonance peak at 530 nm and the appearance of new features in the 620-800 nm regions in their absorption spectra. The particles were stabilized against salt-induced aggregation upon the adsorption of single-stranded DNA. The PCR products, without any additional processing, were hybridized with a 17-base probe prior to exposure to GNPs. At a critical annealing temperature (55 0C) that differentiated matched and mismatched base pairing, the probe was hybridized to pig PCR product and dehybridized from the deer product. The dehybridized probe stuck to GNPs to prevent them from salt-induced aggregation and retained their characteristic red color. Hybridization of a 27-nucleotide probe to swine mitochondrial DNA identified them in pork-venison, pork-shad and venison-shad binary admixtures, eliminating the need of PCR amplification. Thus the assay was applied to authenticate species both in PCR-amplified and non-amplified heterogeneous biological samples. The results were determined visually and validated by absorption spectroscopy. The entire assay (hybridization plus visual detection) was performed in less than 10 min. The LOD (for genomic DNA) of the assay was 6 μg ml-1 swine DNA in mixed meat samples. We believe the assay can be applied for species assignment in food analysis, mismatch detection in genetic screening and homology studies between closely related species.

  4. Nanoparticle sensor for label free detection of swine DNA in mixed biological samples

    Science.gov (United States)

    Ali, M. E.; Hashim, U.; Mustafa, S.; Che Man, Y. B.; Yusop, M. H. M.; Bari, M. F.; Islam, Kh N.; Hasan, M. F.

    2011-05-01

    We used 40 ± 5 nm gold nanoparticles (GNPs) as colorimetric sensor to visually detect swine-specific conserved sequence and nucleotide mismatch in PCR-amplified and non-amplified mitochondrial DNA mixtures to authenticate species. Colloidal GNPs changed color from pinkish-red to gray-purple in 2 mM PBS. Visually observed results were clearly reflected by the dramatic reduction of surface plasmon resonance peak at 530 nm and the appearance of new features in the 620-800 nm regions in their absorption spectra. The particles were stabilized against salt-induced aggregation upon the adsorption of single-stranded DNA. The PCR products, without any additional processing, were hybridized with a 17-base probe prior to exposure to GNPs. At a critical annealing temperature (55 °C) that differentiated matched and mismatched base pairing, the probe was hybridized to pig PCR product and dehybridized from the deer product. The dehybridized probe stuck to GNPs to prevent them from salt-induced aggregation and retained their characteristic red color. Hybridization of a 27-nucleotide probe to swine mitochondrial DNA identified them in pork-venison, pork-shad and venison-shad binary admixtures, eliminating the need of PCR amplification. Thus the assay was applied to authenticate species both in PCR-amplified and non-amplified heterogeneous biological samples. The results were determined visually and validated by absorption spectroscopy. The entire assay (hybridization plus visual detection) was performed in less than 10 min. The LOD (for genomic DNA) of the assay was 6 µg ml - 1 swine DNA in mixed meat samples. We believe the assay can be applied for species assignment in food analysis, mismatch detection in genetic screening and homology studies between closely related species.

  5. Fast screening of ketamine in biological samples based on molecularly imprinted photonic hydrogels

    International Nuclear Information System (INIS)

    Graphical abstract: A novel label-free colorimetric chemosensor: with the increase in the concentration of ketamine, the Bragg diffraction peak of MIPHs gradually shifted to the longer wavelength region. Accompanying the peak shift, the color change of MIPHs was also observed obviously: from green to red. Highlights: ► We developed the label-free colorimetric MIPHs for handy and fast screening of ketamine. ► The obvious color change of MIPHs was observed upon ketamine. ► The MIPHs exhibited good sensing abilities in an aqueous environment. ► The sensing mechanisms of the water-compatible MIPHs were investigated. ► The MIPHs were employed to screening ketamine in real biological samples. -- Abstract: A novel label-free colorimetric chemosensor was developed for handy and fast screening of ketamine with high sensitivity and specificity based on molecularly imprinted photonic hydrogels (MIPHs) that combined the colloidal-crystal with molecular imprinting technique. The unique inverse opal arrays with a thin polymer wall in which the imprinted nanocavities of ketamine moleculars distributed allowed high sensitive, quick responsive, specific detection of the target analyte, and good regenerating ability in an aqueous environment. Due to the hierarchical inverse opal structural characteristics, the specific ketamine molecular recognition process can induce obvious swelling of the MIPHs to be directly transferred into visually perceptible optical signal (change in color) which can be detected by the naked eye through Bragg diffractive shifts of ordered macroporous arrays. In order to enhance the recognition ability in aqueous environments, the MIPHs were designed as water-compatible and synthesized in a water–methanol system. The molecular recognition mechanisms were investigated. The proposed MIPHs were successfully employed to screen trace level ketamine in human urine and saliva samples, exhibiting high sensitivity, rapid response, and specificity in the

  6. Nanoparticle sensor for label free detection of swine DNA in mixed biological samples

    Energy Technology Data Exchange (ETDEWEB)

    Ali, M E; Hashim, U [Institute of Nano Electronic Engineering (INNE), Universiti Malaysia Perlis, Lot 104-108, Tingkat 1, Block A, Taman Pertiwi Indah, Jalan Kangar-Alor Star, Seriab, 01000 Kangar, Perlis (Malaysia); Mustafa, S; Che Man, Y B; Yusop, M H M [Halal Products Research Institute, Universiti Putra Malaysia, 43400 UPM Serdang, Selangor (Malaysia); Bari, M F [School of Materials Engineering, University Malaysia Perlis, Seriab 01000, Kangar, Perlis (Malaysia); Islam, Kh N [Department of Preclinical Sciences, Faculty of Veterinary Medicine, Universiti Putra Malaysia, 43400 UPM Serdang, Selangor (Malaysia); Hasan, M F, E-mail: uda@unimap.edu.my [Department of Crop Science, Faculty of Agriculture, Universiti Putra Malaysia, 43400 UPM Serdang, Selangor (Malaysia)

    2011-05-13

    We used 40 {+-} 5 nm gold nanoparticles (GNPs) as colorimetric sensor to visually detect swine-specific conserved sequence and nucleotide mismatch in PCR-amplified and non-amplified mitochondrial DNA mixtures to authenticate species. Colloidal GNPs changed color from pinkish-red to gray-purple in 2 mM PBS. Visually observed results were clearly reflected by the dramatic reduction of surface plasmon resonance peak at 530 nm and the appearance of new features in the 620-800 nm regions in their absorption spectra. The particles were stabilized against salt-induced aggregation upon the adsorption of single-stranded DNA. The PCR products, without any additional processing, were hybridized with a 17-base probe prior to exposure to GNPs. At a critical annealing temperature (55 {sup 0}C) that differentiated matched and mismatched base pairing, the probe was hybridized to pig PCR product and dehybridized from the deer product. The dehybridized probe stuck to GNPs to prevent them from salt-induced aggregation and retained their characteristic red color. Hybridization of a 27-nucleotide probe to swine mitochondrial DNA identified them in pork-venison, pork-shad and venison-shad binary admixtures, eliminating the need of PCR amplification. Thus the assay was applied to authenticate species both in PCR-amplified and non-amplified heterogeneous biological samples. The results were determined visually and validated by absorption spectroscopy. The entire assay (hybridization plus visual detection) was performed in less than 10 min. The LOD (for genomic DNA) of the assay was 6 {mu}g ml{sup -1} swine DNA in mixed meat samples. We believe the assay can be applied for species assignment in food analysis, mismatch detection in genetic screening and homology studies between closely related species.

  7. Non-target time trend screening: a data reduction strategy for detecting emerging contaminants in biological samples

    OpenAIRE

    Plassmann, Merle M.; Tengstrand, Erik; Åberg, K. Magnus; Benskin, Jonathan P.

    2016-01-01

    Non-targeted mass spectrometry-based approaches for detecting novel xenobiotics in biological samples are hampered by the occurrence of naturally fluctuating endogenous substances, which are difficult to distinguish from environmental contaminants. Here, we investigate a data reduction strategy for datasets derived from a biological time series. The objective is to flag reoccurring peaks in the time series based on increasing peak intensities, thereby reducing peak lists to only those which m...

  8. BORRELIA BURGDORFERI DNA IN BIOLOGICAL SAMPLES FROM PATIENTS WITH SARCOIDOSIS USING THE POLYMERASE CHAIN REACTION TECHNIQUE

    Institute of Scientific and Technical Information of China (English)

    连伟; 罗慰慈

    1995-01-01

    Polymerase chain reaction (PCR) was used to detect the presence of Borretia burgdoferi DNA in biological samples from patients with sarcoidcsis. The target DNA sequence was of chromosomal origin. The amplified DNA sequence was analyzed by agarose gel electrophoresis, PAGE with silver staining, and the identity of amplified DNA was confirmed by restriction enzyme cleavage and DNA-DNA hybridlzation with a 32P-labelled probe. The assay was sensitive to fewer than two copies of B. burgdor feri genome, even in the presence of a 104-fold excess of human eukaryotic DNA, and was also specific to different B. burgdorferl strains tested. Sera seroiogieally positive to B. burgdorferi (n=26), broncbemlveolar lavage fluid and supematant of BALF (n=26) and peripheral blood (n=9) from sarcoidosis patients were tested. The positive rate was low (4/26, 2/26, and 0/9, respectively). It was considered that DNA from B. bur gdor feri may be identified in a minority of patients with s,arcoidosis, and it may play a pathogenetic rote in such cases. More studies need to be done before advancing the hypothesis of an etiologic role of B. burgdorferi in sarcoidosis.

  9. Substrate-zymography: a still worthwhile method for gelatinases analysis in biological samples.

    Science.gov (United States)

    Ricci, Serena; D'Esposito, Vittoria; Oriente, Francesco; Formisano, Pietro; Di Carlo, Angelina

    2016-08-01

    Matrix metallo-proteinases (MMPs) are a family of zinc-dependent endopeptidases, capable of degrading all the molecular components of extracellular matrix. A class of MMPs is gelatinases which includes gelatinase A or MMP-2 (72 kDa) and gelatinase B or MMP-9 (92 kDa), which have been shown to play critical roles in pathophysiology of many human disease and, in particular, cancer progression. For these reasons they obtained a great interest as potential non-invasive biomarker in providing useful clinical information in cancer diagnosis and therapy. A sensitive and unexpensive method for analysis of gelatinases is the gelatine zymography, which allows to measure the relative amounts of active and inactive enzymes in body fluids and tissue extracts. The procedure involves the electrophoretic separation of proteins under denaturing but non reducing conditions through a polyacrylamide gel containing a synthetic substrate (gelatin). The aim of this mini-review has been to describe the general principles of gelatine zymography technique, underling the main advantages and disadvantages. Even though an improvement of this method is necessary for a better applicability in laboratory medicine, gelatine zymography represents the most convenient method to detect the activity of the different gelatinases from a wide range of biological samples. PMID:26641968

  10. The method of radioactive tracer for measuring the amount of inorganic nanoparticles in biological samples

    Science.gov (United States)

    Buzulukov, Yu; Antsiferova, A.; Demin, V. A.; Demin, V. F.; Kashkarov, P.

    2015-11-01

    The method to measure the mass of inorganic nanoparticles in biological (or any other samples) using nanoparticles labeled with radioactive tracers is developed and applied to practice. The tracers are produced in original nanoparticles by radioactive activation of some of their atomic nuclei. The method of radioactive tracers demonstrates a sensitivity, specificity and accuracy equal or better than popular methods of optical and mass spectrometry, or electron microscopy and has some specific advantages. The method can be used for study of absorption, distribution, metabolism and excretion in living organism, as well as in ecological and fundamental research. It was used in practice to study absorption, distribution, metabolism and excretion of nanoparticles of Ag, Au, Se, ZnO, TiO2 as well as to study transportation of silver nanoparticles through the barriers of blood-brain, placenta and milk gland of rats. Brief descriptions of data obtained in experiments with application of this method included in the article. The method was certified in Russian Federation standard system GOST-R and recommended by the Russian Federation regulation authority ROSPOTREBNADZOR for measuring of toxicokinetic and organotropy parameters of nanoparticles.

  11. Synthesis of [13C6]-labelled phenethylamine derivatives for drug quantification in biological samples.

    Science.gov (United States)

    Karlsen, Morten; Liu, HuiLing; Berg, Thomas; Johansen, Jon Eigill; Hoff, Bård Helge

    2014-05-15

    The availability of high-quality (13)C-labelled internal standards will improve accurate quantification of narcotics and drugs in biological samples. Thus, the synthesis of 10 [(13)C6]-labelled phenethylamine derivatives, namely amphetamine, methamphetamine, 3,4-methylenedioxyamphetamine, 3,4-methylenedioxymethamphetamine, 3,4-methylenedioxy-N-ethylamphetamine, 4-methoxyamphetamine, 4-methoxymethamphetamine, 3,5-dimethoxyphenethylamine 4-bromo-2,5-dimethoxyphenethylamine and 2,5-dimethoxy-4-iodophenethylamine, have been undertaken. [(13)C6]-Phenol proved to be an excellent starting material for making (13)C-labelled narcotic substances in the phenethylamine class, and a developed Stille-type coupling enabled an efficient synthesis of the 3,4-methylenedioxy and 4-methoxy derivatives. The pros and cons of alternative routes and transformations are also discussed. The [(13)C6]-labelled compounds are intended for use as internal standards in forensic analysis, health sciences and metabolomics studies by gas chromatography-mass spectrometry and liquid chromatography-tandem mass spectrometry. PMID:24634286

  12. Development of novel separation techniques for biological samples in capillary electrophoresis

    Energy Technology Data Exchange (ETDEWEB)

    Chang, H.T.

    1994-07-27

    This dissertation includes three different topics: general introduction of capillary electrophoresis (CE); gradient in CE and CE in biological separations; and capillary gel electrophoresis (CGE) for DNA separation. Factors such as temperature, viscosity, pH, and the surface of capillary walls affecting the separation performance are demonstrated. A pH gradient between 3.0 and 5.2 is useful to improve the resolution among eight different organic acids. A flow gradient due to the change in the concentration of surfactant, which is able to coat to the capillary wall to change the flow rate and its direction, is also shown as a good way to improve the resolution for organic compounds. A temperature gradient caused by joule heat is shown by voltage programming to enhance the resolution and shorten the separation time for several phenolic compounds. The author also shows that self-regulating dynamic control of electroosmotic flow in CE by simply running separation in different concentrations of surfactant has less matrix effect on the separation performance. One of the most important demonstrations in this dissertation is that the author proposes on-column reaction which gives several advantages including the use of a small amount of sample, low risk of contamination, and time saving and kinetic features. The author uses this idea with laser induced fluorescence (LIF) as a detection mode to detect an on-column digestion of sub-ng of protein. This technique also is applied to single cell analysis in the group.

  13. Dimensional comparison between amplitude-modulation atomic force microscopy and scanning ion conductance microscopy of biological samples

    Science.gov (United States)

    Kim, Joonhui; Choi, MyungHoon; Jung, Goo-Eun; Rahim Ferhan, Abdul; Cho, Nam-Joon; Cho, Sang-Joon

    2016-08-01

    The range of scanning probe microscopy (SPM) applications for atomic force microscopy (AFM) is expanding in the biological sciences field, reflecting an increasing demand for tools that can improve our fundamental understanding of the physics behind biological systems. However, the complexity associated with applying SPM techniques in biomedical research hampers the full exploitation of its capabilities. Recently, the development of scanning ion conductance microscopy (SICM) has overcome these limitations and enabled contact-free, high resolution imaging of live biological specimens. In this work, we demonstrate the limitation of AFM for imaging biological samples in liquid due to artifacts arising from AFM tip–sample interaction, and how SICM imaging is able to overcome those limitations with contact-free scanning. We also demonstrate that SICM measurements, when compared to AFM, show better fit to the actual dimensions of the biological samples. Our results highlight the superiority of SICM imaging, enabling it to be widely adopted as a general and versatile research tool for biological studies in the nanoscale.

  14. Generation of parameters required for estimation of organically bound tritium in plant samples

    International Nuclear Information System (INIS)

    This paper presents the results of estimation of model parameters, required for calculation of Organically Bound Tritium, namely fractional water content (WCp) and water equivalent factor (WEQp) of a few plant samples commonly observed at Kaiga site. Paper also presents the results of estimation of exchangeable and non exchangeable hydrogen atoms present in those plant samples. Fractional water content of leafy vegetables varied from 0.76 to 0.95, that of fruit samples varied from 0.72 to 0.96, that of leafy vegetable sample varied from 0.69 to 0.97 and that of cereals varied from 0.04 to 0.29. Water equivalent factor is found to be more or less constant irrespective of the sample type. The total hydrogen content in the dry matter is more or less constant even though relative concentration of various constituents such as protein, fat and carbohydrate are different for different types of samples. The carbon bound hydrogen atoms in the dry matter are more than those bound to atoms other than carbon in the samples considered in this work. (author)

  15. Characteristic and maintenance requirements for the sampling pump of the stationary gaseous effluent monitor

    International Nuclear Information System (INIS)

    The stationary gaseous effluent monitor is equipment intended for continuously monitoring radioactivity in gaseous effluents released from the nuclear facilities. This monitor consists of sampling, detection and control assemblies. The sampling pump is a most integral part of the sampling assembly and required to be operated with an appropriate pressure to keep the continuous monitoring. However, in 1998, the failures of sampling pumps had successively occurred. This was due to the overload in pressure at the intake or the outlet. To prevent from the failures of sampling pumps, the overload characteristics and the mean time between failures (MTBF) were investigated. The following results were obtained. (1) The performance and tolerance tests with rapid increase of air pressure were carried out. The sampling pumps could withstand two or three times higher pressure than the regularly operating pressure during a few minutes. But, after that, the pump suddenly fell down by an over-current relay (OCR). (2) The MTBF were analyzed on the basis of the maintenance and repair records over a period from 1988 to 1998. The MTBF of a sampling pump were in the range from 7,600 to 35,500 hours. For a preventive maintenance, the consumption parts, such as a carbon blade and a bearing of rotor shaft, etc., should be replaced periodically. (author)

  16. Method development for mass spectrometry based molecular characterization of fossil fuels and biological samples

    Science.gov (United States)

    Mahat, Rajendra K.

    In an analytical (chemical) method development process, the sample preparation step usually determines the throughput and overall success of the analysis. Both targeted and non-targeted methods were developed for the mass spectrometry (MS) based analyses of fossil fuels (coal) and lipidomic analyses of a unique micro-organism, Gemmata obscuriglobus. In the non-targeted coal analysis using GC-MS, a microwave-assisted pressurized sample extraction method was compared with the traditional extraction method, such as Soxhlet. On the other hand, methods were developed to establish a comprehensive lipidomic profile and to confirm the presence of endotoxins (a.k.a. lipopolysaccharides, LPS) in Gemmata.. The performance of pressurized heating techniques employing hot-air oven and microwave irradiation were compared with that of Soxhlet method in terms of percentage extraction efficiency and extracted analyte profiles (via GC-MS). Sub-bituminous (Powder River Range, Wyoming, USA) and bituminous (Fruitland formation, Colorado, USA) coal samples were tested. Overall 30-40% higher extraction efficiencies (by weight) were obtained with a 4 hour hot-air oven and a 20 min microwave-heating extraction in a pressurized container when compared to a 72 hour Soxhlet extraction. The pressurized methods are 25 times more economic in terms of solvent/sample amount used and are 216 times faster in term of time invested for the extraction process. Additionally, same sets of compounds were identified by GC-MS for all the extraction methods used: n-alkanes and diterpanes in the sub-bituminous sample, and n-alkanes and alkyl aromatic compounds in the bituminous coal sample. G. obscuriglobus, a nucleated bacterium, is a micro-organism of high significances from evolutionary, cell and environmental biology standpoints. Although lipidomics is an essential tool in microbiological systematics and chemotaxonomy, complete lipid profile of this bacterium is still lacking. In addition, the presence of

  17. Metais pesados em amostras biológicas de bovinos Heavy metals in cattle biological samples

    Directory of Open Access Journals (Sweden)

    Maria Verônica de Souza

    2009-09-01

    Full Text Available O objetivo deste trabalho foi determinar a concentração de metais pesados no sangue (Pb, Ni e Cd, soro (Cu e Zn, pelo e leite (Pb, Ni, Cd, Cu e Zn de bovinos criados em área industrializada (com siderúrgicas e não-industrial do Estado de Minas Gerais, em amostras coletadas em duas épocas (inverno e verão, buscando avaliar a contaminação em animais em função do ambiente de exposição e da estação do ano. O local de criação dos animais afetou significativamente somente a concentração de Cu obtida nas amostras de soro, com maiores valores determinados no grupo de bovinos da região industrializada. A época de amostragem afetou a concentração dos metais Cu (soro, Zn (soro e leite, Pb (sangue e Cd (sangue e pelo, com as determinações efetuadas no verão proporcionando maiores teores do que as executadas no inverno, à exceção do Cd avaliado no pelo. Interações significativas (PThe aim of this research was to determine the heavy metals concentration in blood (Pb, Ni and Cd, serum (Cu and Zn, hair and milk (Pb, Ni, Cd, Cu and Zn of cattle raised in industrial (with steel mill and non-industrial areas in Minas Gerais, Brazil. The samples were collected during summer and winter, aiming to verify animals contamination related to environment and year season. The environment significantly influenced the concentration of Cu obtained on serum samples, with higher values for cattle from the industrialized area. The sampling time affected the concentration of Cu (serum, Zn (serum and milk, Pb (blood and Cd (blood and hair, with higher values for summer, except for Cd measured on hair. Meaningful interactions (P<0.05 between environment and year season were identified for Cu (hair and milk, Zn (hair and Ni (serum, hair and milk. The results obtained show that the presence of steel mills in a determined area does not mean, necessarily that higher concentration of heavy metals will be found in cattle biological matrices. The seasonality

  18. Production and use of mycotoxins uniformly enriched with stable isotopes for their dosage in biological samples: (3) Tools for pharmacokinetics and as internal standards

    International Nuclear Information System (INIS)

    Pharmacological studies of exogenous compounds often encounter problems: these compounds are in such infinitesimal amount in their biological matrices, that they require particular detection method. We have implemented an alternative method to the usual radioactivity, based on incorporation of stable isotopes, through the example of biosynthesis of uniformly 13C enriched mycotoxins. The isotopic cluster obtained from a 10% 13C enrichment of several mycotoxins (and their metabolites) can be easily recovered from biological tissue samples by mass spectrometry allowing an easy discrimination from natural non-enriched compounds. We illustrate such pharmacological approaches by in vitro zearalenone metabolism. Such enriched compound can also be used as internal standard with high reliability in order to quantify mycotoxins in contaminated food samples. (authors)

  19. Automated extraction of DNA from reference samples from various types of biological materials on the Qiagen BioRobot EZ1 Workstation

    DEFF Research Database (Denmark)

    Stangegaard, Michael; Jørgensen, Mads; Hansen, Anders Johannes;

    2009-01-01

    We have validated and implemented a protocol for DNA extraction from various types of biological materials using a Qiagen BioRobot EZ1 Workstation. The sample materials included whole blood, blood from deceased, buccal cells on Omni swabs and FTA Cards, blood on FTA Cards and cotton swabs, and...... muscle biopsies. The DNA extraction was validated according to EN/ISO 17025 for the STR kits AmpFlSTR« Identifiler« and AmpFlSTR« Yfiler« (Applied Biosystems). Of 298 samples extracted, 11 (4%) did not yield acceptable results. In conclusion, we have demonstrated that extraction of DNA from various types...... of biological material can be performed quickly and without the use of hazardous chemicals, and that the DNA may be successfully STR typed according to the requirements of forensic genetic investigations accredited according to EN/ISO 17025...

  20. Production and use of mycotoxins uniformly enriched with stable isotopes for their dosage in biological samples: (3) Tools for pharmacokinetics and as internal standards

    Energy Technology Data Exchange (ETDEWEB)

    Bravin, F.; Delaforge, M.; Duca, R.C. [CNRS, URA 2096, F-91191 Gif Sur Yvette (France); Bravin, F.; Delaforge, M.; Duca, R.C. [CEA Saclay, DSV, DBJC, SBFM, F-91191 Gif Sur Yvette (France); Pean, M. [CEA Cadarache, DEVM, GRAP, St Paul Les Durance (France); Puel, O. [INRA, Lab Pharmacol Toxicol, UR 66, Toulouse (France)

    2007-07-01

    Pharmacological studies of exogenous compounds often encounter problems: these compounds are in such infinitesimal amount in their biological matrices, that they require particular detection method. We have implemented an alternative method to the usual radioactivity, based on incorporation of stable isotopes, through the example of biosynthesis of uniformly {sup 13}C enriched mycotoxins. The isotopic cluster obtained from a 10% {sup 13}C enrichment of several mycotoxins (and their metabolites) can be easily recovered from biological tissue samples by mass spectrometry allowing an easy discrimination from natural non-enriched compounds. We illustrate such pharmacological approaches by in vitro zearalenone metabolism. Such enriched compound can also be used as internal standard with high reliability in order to quantify mycotoxins in contaminated food samples. (authors)

  1. Sample requirements and design of an inter-laboratory trial for radiocarbon laboratories

    International Nuclear Information System (INIS)

    An on-going inter-comparison programme which is focused on assessing and establishing consensus protocols to be applied in the identification, selection and sub-sampling of materials for subsequent 14C analysis is described. The outcome of the programme will provide a detailed quantification of the uncertainties associated with 14C measurements including the issues of accuracy and precision. Such projects have become recognised as a fundamental aspect of continuing laboratory quality assurance schemes, providing a mechanism for the harmonisation of measurements and for demonstrating the traceability of results. The design of this study and its rationale are described. In summary, a suite of core samples has been defined which will be made available to both AMS and radiometric laboratories. These core materials are representative of routinely dated material and their ages span the full range of the applied 14C time-scale. Two of the samples are of wood from the German and Irish dendrochronologies, thus providing a direct connection to the master dendrochronological calibration curve. Further samples link this new inter-comparison to past studies. Sample size and precision have been identified as being of paramount importance in defining dating confidence, and so several core samples have been identified for more in-depth study of these practical issues. In addition to the core samples, optional samples have been identified and prepared specifically for either AMS and/or radiometric laboratories. For AMS laboratories, these include bone, textile, leather and parchment samples. Participation in the study requires a commitment to a minimum of 10 core analyses, with results to be returned within a year

  2. Data Quality Objectives for Regulatory Requirements for Hazardous and Radioactive Air Emissions Sampling and Analysis

    Energy Technology Data Exchange (ETDEWEB)

    MULKEY, C.H.

    1999-07-06

    This document describes the results of the data quality objective (DQO) process undertaken to define data needs for state and federal requirements associated with toxic, hazardous, and/or radiological air emissions under the jurisdiction of the River Protection Project (RPP). Hereafter, this document is referred to as the Air DQO. The primary drivers for characterization under this DQO are the regulatory requirements pursuant to Washington State regulations, that may require sampling and analysis. The federal regulations concerning air emissions are incorporated into the Washington State regulations. Data needs exist for nonradioactive and radioactive waste constituents and characteristics as identified through the DQO process described in this document. The purpose is to identify current data needs for complying with regulatory drivers for the measurement of air emissions from RPP facilities in support of air permitting. These drivers include best management practices; similar analyses may have more than one regulatory driver. This document should not be used for determining overall compliance with regulations because the regulations are in constant change, and this document may not reflect the latest regulatory requirements. Regulatory requirements are also expected to change as various permits are issued. Data needs require samples for both radionuclides and nonradionuclide analytes of air emissions from tanks and stored waste containers. The collection of data is to support environmental permitting and compliance, not for health and safety issues. This document does not address health or safety regulations or requirements (those of the Occupational Safety and Health Administration or the National Institute of Occupational Safety and Health) or continuous emission monitoring systems. This DQO is applicable to all equipment, facilities, and operations under the jurisdiction of RPP that emit or have the potential to emit regulated air pollutants.

  3. Data Quality Objectives for Regulatory Requirements for Hazardous and Radioactive Air Emissions Sampling and Analysis

    International Nuclear Information System (INIS)

    This document describes the results of the data quality objective (DQO) process undertaken to define data needs for state and federal requirements associated with toxic, hazardous, and/or radiological air emissions under the jurisdiction of the River Protection Project (RPP). Hereafter, this document is referred to as the Air DQO. The primary drivers for characterization under this DQO are the regulatory requirements pursuant to Washington State regulations, that may require sampling and analysis. The federal regulations concerning air emissions are incorporated into the Washington State regulations. Data needs exist for nonradioactive and radioactive waste constituents and characteristics as identified through the DQO process described in this document. The purpose is to identify current data needs for complying with regulatory drivers for the measurement of air emissions from RPP facilities in support of air permitting. These drivers include best management practices; similar analyses may have more than one regulatory driver. This document should not be used for determining overall compliance with regulations because the regulations are in constant change, and this document may not reflect the latest regulatory requirements. Regulatory requirements are also expected to change as various permits are issued. Data needs require samples for both radionuclides and nonradionuclide analytes of air emissions from tanks and stored waste containers. The collection of data is to support environmental permitting and compliance, not for health and safety issues. This document does not address health or safety regulations or requirements (those of the Occupational Safety and Health Administration or the National Institute of Occupational Safety and Health) or continuous emission monitoring systems. This DQO is applicable to all equipment, facilities, and operations under the jurisdiction of RPP that emit or have the potential to emit regulated air pollutants

  4. Technical assessment of workplace air sampling requirements at tank farm facilities. Revision 1

    International Nuclear Information System (INIS)

    WHC-CM-1-6 is the primary guidance for radiological control at Westinghouse Hanford Company (WHC). It was written to implement DOE N 5480.6 ''US Department of Energy Radiological Control Manual'' as it applies to programs at Hanford which are now overseen by WHC. As such, it complies with Title 10, Part 835 of the Code of Federal Regulations. In addition to WHC-CM-1-6, there is HSRCM-1, the ''Hanford Site Radiological Control Manual'' and several Department of Energy (DOE) Orders, national consensus standards, and reports that provide criteria, standards, and requirements for workplace air sampling programs. This document provides a summary of these, as they apply to WHC facility workplace air sampling programs. This document also provides an evaluation of the compliance of Tank Farms' workplace air sampling program to the criteria, standards, and requirements and documents compliance with the requirements where appropriate. Where necessary, it also indicates changes needed to bring specific locations into compliance

  5. Latest developments and opportunities for 3D analysis of biological samples by confocal mu-XRF

    Energy Technology Data Exchange (ETDEWEB)

    Perez, Roberto D., E-mail: danperez@famaf.unc.edu.a [FaMAF, Universidad Nacional de Cordoba, Ciudad Universitaria, 5000 Cordoba (Argentina); CONICET, Rivadavia 1917, 1033 Buenos Aires (Argentina); Sanchez, Hector J. [FaMAF, Universidad Nacional de Cordoba, Ciudad Universitaria, 5000 Cordoba (Argentina); CONICET, Rivadavia 1917, 1033 Buenos Aires (Argentina); Perez, Carlos A. [Laboratorio Nacional de Luz Sincrotron-LNLS, POB 6192, 13084-971 Campinas, SP (Brazil); Rubio, Marcelo [FaMAF, Universidad Nacional de Cordoba, Ciudad Universitaria, 5000 Cordoba (Argentina); CONICET, Rivadavia 1917, 1033 Buenos Aires (Argentina); CEPROCOR, Ministerio de Ciencia y Tecnologia de Cordoba, 5164 Santa Maria de Punilla, Cordoba (Argentina)

    2010-02-15

    X-ray fluorescence analysis performed with a primary radiation focused in the micrometer range is known as micro-X-ray fluorescence (mu-XRF). It is characterized by a penetration depth higher than other micro-analytical methods, reaching hundreds of micrometers in biological samples. This characteristic of the X-ray beam can be employed in 3D analysis. An innovative method to perform 3D analysis by mu-XRF is the so-called confocal setup. The confocal setup consists of X-ray lenses in the excitation as well as in the detection channel. In this configuration, a micro-volume defined by the overlap of the foci of both X-ray lenses is analyzed. Scanning this micro-volume through the sample can be used to perform a study in three dimensions. At present, X-ray lenses used in confocal mu-XRF experiments are mainly glass capillaries and polycapillaries. Glass capillaries are used in the excitation channel with sources of high photon flux like synchrotron radiation. Half polycapillaries or conical polycapillary concentrators are used almost exclusively in the detection channel. Spatial resolution of the confocal mu-XRF depends on the dimensions of the foci of both X-ray lenses. The overlap of these foci forms an ellipsoid which is the probing volume of the confocal setup. The axis length of the probing volume reported in confocal mu-XRF experiments are of order of few tens of micrometer. In our confocal setup, we used a commercial glass monocapillary in the excitation channel and a monolithic half polycapillary in the detection channel. The polycapillary was home-made by means of drawing of multibundles of glass capillaries in a heating furnace. The experiment was carried out at the beamline D09B-XRF of the Synchrotron Light National Laboratory (Laboratorio Nacional de Luz Sincrotron, LNLS) using white beam. A model for the theoretical description of X-ray fluorescence intensity registered by confocal mu-XRF was introduced by Malzer and Kanngiebetaer [2005. A model for the

  6. Determination of thorium and uranium in biological samples by inductively coupled plasma mass spectrometry using internal standardisation

    International Nuclear Information System (INIS)

    The Th and U contents of six typical biological samples (for example US NIST SRMs and Japan NIES CRMs) were determined by inductively coupled plasma mass spectrometry (ICP-MS). The internal standardisation method was adopted to compensate for non-spectroscopic interferences arising from matrix elements in the sample solution. Bismuth and Tl were chosen as the internal standards, and the effect of the matrix on the behaviour of their signals was monitored by adding several elements to the NIST human lung sample. It would appear that elements of similar mass give similar signal responses, thus In is unsuitable as the internal standard in this instance. After correction by either Bi or Tl internal standardisation, the results for the Th and U concentrations agreed well with literature values, showing that both are applicable for the determination of Th and U in biological samples. (author)

  7. Correlations among Five Variables and the Biology Performance of a Sample of Jamaican High School Students

    Science.gov (United States)

    Blair-Walters, Shonette; Soyibo, Kola

    2004-01-01

    This study investigates whether or not (a) 252 Jamaican high school students (168 boys, 84 girls, 171 grade 10 and 81 grade 11 students) had favourable attitudes to biology, (b) their level of biology performance was satisfactory, (c) there were significant differences in their performance based on their gender, grade level, school-type,…

  8. The scientific and technical requirements for biology at Australia's Replacement Research Reactor

    International Nuclear Information System (INIS)

    A Symposium and Workshop on Neutrons for Biology was held in the School of Biochemistry and Molecular Biology at the University of Melbourne, under the auspices of AINSE, Univ of Melbourne and ANSTO. Invited talks were given on the subjects of Genome, small-angle neutron scattering (SANS) as a critical framework for understanding bio-molecular, neutron diffraction at high and low resolution, and the investigation of viruses and large-scale biological structures using neutrons. There were also talks from prominent NMR practitioners and X-ray protein crystallographers, with substantial discussion about how the various methods might fit together in the future. Significant progress was made on defining Australia's needs, which include a strong push to use SANS and reflectometry for the study of macromolecular complexes and model membranes, and a modest network of supporting infrastructure in Brisbane, Melbourne and the Sydney Basin. Specific recommendations were that the small-angle neutron scattering and reflectometry instruments in the Replacement Research Reactor (RRR) be pursued with high priority, that there be no specific effort to provide high-resolution protein-crystallography facilities at the RRR, but that a watching brief be kept on instrumentation and sample-preparation technologies elsewhere. A watch be kept on inelastic and quasielastic neutron scattering capabilities elsewhere, although these methods will not initially be pursued at the RRR and that should be input from this community into the design of the biochemistry/chemistry laboratories at the Replacement Research Reactor. It was also recommended that a small number of regional facilities be established (or enhanced) to allow users to perform deuteration of biomolecules. These facilities would be of significant value to the NMR and neutron scattering communities

  9. Data Quality Objectives for Regulatory Requirements for Dangerous Waste Sampling and Analysis

    International Nuclear Information System (INIS)

    This document describes sampling and analytical requirements needed to meet state and federal regulations for dangerous waste (DW). The River Protection Project (RPP) is assigned to the task of storage and interim treatment of hazardous waste. Any final treatment or disposal operations, as well as requirements under the land disposal restrictions (LDRs), fall in the jurisdiction of another Hanford organization and are not part of this scope. The requirements for this Data Quality Objective (DQO) Process were developed using the RPP Data Quality Objective Procedure (Banning 1996), which is based on the U.S. Environmental Protection Agency's (EPA) Guidance for the Data Quality Objectives Process (EPA 1994). Hereafter, this document is referred to as the DW DQO. Federal and state laws and regulations pertaining to waste contain requirements that are dependent upon the composition of the waste stream. These regulatory drivers require that pertinent information be obtained. For many requirements, documented process knowledge of a waste composition can be used instead of analytical data to characterize or designate a waste. When process knowledge alone is used to characterize a waste, it is a best management practice to validate the information with analytical measurements

  10. Accelerator mass spectrometry analysis of 14C-oxaliplatin concentrations in biological samples and 14C contents in biological samples and antineoplastic agents

    Science.gov (United States)

    Toyoguchi, Teiko; Kobayashi, Takeshi; Konno, Noboru; Shiraishi, Tadashi; Kato, Kazuhiro; Tokanai, Fuyuki

    2015-10-01

    Accelerator mass spectrometry (AMS) is expected to play an important role in microdose trials. In this study, we measured the 14C concentration in 14C-oxaliplatin-spiked serum, urine and supernatant of fecal homogenate samples in our Yamagata University (YU) - AMS system. The calibration curves of 14C concentration in serum, urine and supernatant of fecal homogenate were linear (the correlation coefficients were ⩾0.9893), and the precision and accuracy was within the acceptance criteria. To examine a 14C content of water in three vacuum blood collection tubes and a syringe were measured. 14C was not detected from water in these devices. The mean 14C content in urine samples of 6 healthy Japanese volunteers was 0.144 dpm/mL, and the intra-day fluctuation of 14C content in urine from a volunteer was little. The antineoplastic agents are administered to the patients in combination. Then, 14C contents of the antineoplastic agents were quantitated. 14C contents were different among 10 antineoplastic agents; 14C contents of paclitaxel injection and docetaxel hydrate injection were higher than those of the other injections. These results indicate that our quantitation method using YU-AMS system is suited for microdosing studies and that measurement of baseline and co-administered drugs might be necessary for the studies in low concentrations.

  11. Development of a biaxial compression device for biological samples: preliminary experimental results for a closed cell foam.

    Science.gov (United States)

    Little, J P; Tevelen, G; Adam, C J; Evans, J H; Pearcy, M J

    2009-07-01

    Biological tissues are subjected to complex loading states in vivo and in order to define constitutive equations that effectively simulate their mechanical behaviour under these loads, it is necessary to obtain data on the tissue's response to multiaxial loading. Single axis and shear testing of biological tissues is often carried out, but biaxial testing is less common. We sought to design and commission a biaxial compression testing device, capable of obtaining repeatable data for biological samples. The apparatus comprised a sealed stainless steel pressure vessel specifically designed such that a state of hydrostatic compression could be created on the test specimen while simultaneously unloading the sample along one axis with an equilibrating tensile pressure. Thus a state of equibiaxial compression was created perpendicular to the long axis of a rectangular sample. For the purpose of calibration and commissioning of the vessel, rectangular samples of closed cell ethylene vinyl acetate (EVA) foam were tested. Each sample was subjected to repeated loading, and nine separate biaxial experiments were carried out to a maximum pressure of 204 kPa (30 psi), with a relaxation time of two hours between them. Calibration testing demonstrated the force applied to the samples had a maximum error of 0.026 N (0.423% of maximum applied force). Under repeated loading, the foam sample demonstrated lower stiffness during the first load cycle. Following this cycle, an increased stiffness, repeatable response was observed with successive loading. While the experimental protocol was developed for EVA foam, preliminary results on this material suggest that this device may be capable of providing test data for biological tissue samples. The load response of the foam was characteristic of closed cell foams, with consolidation during the early loading cycles, then a repeatable load-displacement response upon repeated loading. The repeatability of the test results demonstrated the

  12. Critical tests for determination of microbiological quality and biological activity in commercial vermicompost samples of different origins.

    Science.gov (United States)

    Grantina-Ievina, Lelde; Andersone, Una; Berkolde-Pīre, Dace; Nikolajeva, Vizma; Ievinsh, Gederts

    2013-12-01

    The aim of the present paper was to show that differences in biological activity among commercially produced vermicompost samples can be found by using a relatively simple test system consisting of microorganism tests on six microbiological media and soilless seedling growth tests with four vegetable crop species. Significant differences in biological properties among analyzed samples were evident both at the level of microbial load as well as plant growth-affecting activity. These differences were mostly manufacturer- and feedstock-associated, but also resulted from storage conditions of vermicompost samples. A mature vermicompost sample that was produced from sewage sludge still contained considerable number of Escherichia coli. Samples from all producers contained several potentially pathogenic fungal species such as Aspergillus fumigatus, Pseudallescheria boidii, Pseudallescheria fimeti, Pseudallescheria minutispora, Scedosporium apiospermum, Scedosporium prolificans, Scopulariopsis brevicaulis, Stachybotrys chartarum, Geotrichum spp., Aphanoascus terreus, and Doratomyces columnaris. In addition, samples from all producers contained plant growth-promoting fungi from the genera Trichoderma and Mortierella. The described system can be useful both for functional studies aiming at understanding of factors affecting quality characteristics of vermicompost preparations and for routine testing of microbiological quality and biological activity of organic waste-derived composts and vermicomposts. PMID:23504062

  13. Development of a radiochemical neutron activation analysis procedure for determination of rhenium in biological and environmental samples at ultratrace level

    Czech Academy of Sciences Publication Activity Database

    Kučera, Jan; Byrne, A. R.; Mizera, Jiří; Lučaníková, M.; Řanda, Zdeněk

    2006-01-01

    Roč. 269, č. 2 (2006), s. 251-257. ISSN 0236-5731 R&D Projects: GA ČR(CZ) GA203/04/0943 Institutional research plan: CEZ:AV0Z10480505 Keywords : radiochemical neutron activation analysis * rhenium * biological and environmental samples Subject RIV: CB - Analytical Chemistry, Separation Impact factor: 0.509, year: 2006

  14. Interaction between selenium and mercury in biological samples of Pakistani myocardial infarction patients at different stages as related to controls.

    Science.gov (United States)

    Afridi, Hassan Imran; Kazi, Tasneem Gul; Talpur, Farah Naz; Kazi, Atif; Arain, Sadaf Sadia; Arain, Salma Aslam; Brahman, Kapil Dev; Panhwar, Abdul Haleem; Naeemullah

    2014-05-01

    It has been speculated that trace elements may a play role in the pathogenesis of heart diseases. In the present study, we aimed to assess the levels of selenium (Se) and mercury (Hg) in biological samples (whole blood, urine, and scalp hair) of myocardial infarction (MI) patients of both genders (age range 45-60 years) at the first, second, and third heart attack (n = 130), hospitalized in a cardiac ward of a civil hospital of Hyderabad City (Pakistan). For comparison, healthy age-matched referent subjects (n = 61) of both genders were also selected. Se and Hg in biological samples were measured by electrothermal atomic absorption spectrometry and cold vapor atomic absorption spectrometry, prior to microwave acid digestion, respectively. The validity of the methodology was checked by biological certified reference materials. During this study, 78 % of the 32 registered patients of third MI attack (aged >50 years) died. The concentration of Se was decreased in scalp hair and blood samples of MI patients, while Hg was higher in all biological samples as compared to referent subjects. Se concentration was inversely associated with the risk of MI attacks in both genders. These results add to an increasing body of evidence that Se is a protective element for cardiovascular health. PMID:24643467

  15. Sample size requirements and analysis of tag recoveries for paired releases of lake trout

    Science.gov (United States)

    Elrod, Joseph H.; Frank, Anthony

    1990-01-01

    A simple chi-square test can be used to analyze recoveries from a paired-release experiment to determine whether differential survival occurs between two groups of fish. The sample size required for analysis is a function of (1) the proportion of fish stocked, (2) the expected proportion at recovery, (3) the level of significance (a) at which the null hypothesis is tested, and (4) the power (1-I?) of the statistical test. Detection of a 20% change from a stocking ratio of 50:50 requires a sample of 172 (I?=0.10; 1-I?=0.80) to 459 (I?=0.01; 1-I?=0.95) fish. Pooling samples from replicate pairs is sometimes an appropriate way to increase statistical precision without increasing numbers stocked or sampling intensity. Summing over time is appropriate if catchability or survival of the two groups of fish does not change relative to each other through time. Twelve pairs of identical groups of yearling lake trout Salvelinus namaycush were marked with coded wire tags and stocked into Lake Ontario. Recoveries of fish at ages 2-8 showed differences of 1-14% from the initial stocking ratios. Mean tag recovery rates were 0.217%, 0.156%, 0.128%, 0.121%, 0.093%, 0.042%, and 0.016% for ages 2-8, respectively. At these rates, stocking 12,100-29,700 fish per group would yield samples of 172-459 fish at ages 2-8 combined.

  16. Exploring the cellular and tissue uptake of nanomaterials in a range of biological samples using multimodal nonlinear optical microscopy

    Science.gov (United States)

    Johnston, Helinor J.; Mouras, Rabah; Brown, David M.; Elfick, Alistair; Stone, Vicki

    2015-12-01

    The uptake of nanomaterials (NMs) by cells is critical in determining their potential biological impact, whether beneficial or detrimental. Thus, investigation of NM internalization by cells is a common consideration in hazard and efficacy studies. There are currently a number of approaches that are routinely used to investigate NM-cell interactions, each of which have their own advantages and limitations. Ideally, imaging modalities used to investigate NM uptake by cells should not require the NM to be labelled (e.g. with fluorophores) to facilitate its detection. We present a multimodal imaging approach employing a combination of label-free microscopies that can be used to investigate NM-cell interactions. Coherent anti-Stokes Raman scattering microscopy was used in combination with either two-photon photoluminescence or four-wave mixing (FWM) to visualize the uptake of gold or titanium dioxide NMs respectively. Live and fixed cell imaging revealed that NMs were internalized by J774 macrophage and C3A hepatocyte cell lines (15-31 μg ml-1). Sprague Dawley rats were exposed to NMs (intratracheal instillation, 62 μg) and NMs were detected in blood and lung leucocytes, lung and liver tissue, demonstrating that NMs could translocate from the exposure site. Obtained data illustrate that multimodal nonlinear optical microscopy may help overcome current challenges in the assessment of NM cellular uptake and biodistribution. It is therefore a powerful tool that can be used to investigate unlabelled NM cellular and tissue uptake in three dimensions, requires minimal sample preparation, and is applicable to live and fixed cells.

  17. Quality assurance and reference material requirements and considerations for environmental sample analysis in nuclear forensics

    International Nuclear Information System (INIS)

    Full text: High-sensitivity nuclear environmental sampling and analysis techniques have been proven in their ability to verify declared nuclear activities, as well as to assist in the detection of undeclared nuclear activities and facilities. Following the Gulf War, the capability and revealing power of environmental sampling and analysis techniques to support international safeguards was demonstrated and subsequently adopted by the International Atomic Energy Agency (IAEA) as routine safeguards measures in safeguards inspections and verifications. In addition to having been proved useful in international safeguards, environmental sampling and analysis techniques have demonstrated their utility in identifying the origins of 'orphaned' nuclear material, as well as the origin of intercepted smuggled nuclear material. Today, environmental sampling and analysis techniques are now being applied in six broad areas to support nonproliferation, disarmament treaty verification, national and international nuclear security, and environmental stewardship of weapons production activities. Consequently, more and more laboratories around the world are establishing capabilities or expanding capabilities to meet these growing applications, and as such requirements for quality assurance and control are increasing. The six areas are: 1) Nuclear safeguards; 2) Nuclear forensics/illicit trafficking; 3) Ongoing monitoring and verification (OMV); 4) Comprehensive Test Ban Treaty (CTBT); 5) Weapons dismantlement/materials disposition; and 6) Research and development (R and D)/environmental stewardship/safety. Application of environmental sampling and analysis techniques and resources to illicit nuclear material trafficking, while embodying the same basic techniques and resources, does have unique requirements for sample management, handling, protocols, chain of custody, archiving, and data interpretation. These requirements are derived from needs of how data from nuclear forensics

  18. State of the art of environmentally friendly sample preparation approaches for determination of PBDEs and metabolites in environmental and biological samples: A critical review.

    Science.gov (United States)

    Berton, Paula; Lana, Nerina B; Ríos, Juan M; García-Reyes, Juan F; Altamirano, Jorgelina C

    2016-01-28

    Green chemistry principles for developing methodologies have gained attention in analytical chemistry in recent decades. A growing number of analytical techniques have been proposed for determination of organic persistent pollutants in environmental and biological samples. In this light, the current review aims to present state-of-the-art sample preparation approaches based on green analytical principles proposed for the determination of polybrominated diphenyl ethers (PBDEs) and metabolites (OH-PBDEs and MeO-PBDEs) in environmental and biological samples. Approaches to lower the solvent consumption and accelerate the extraction, such as pressurized liquid extraction, microwave-assisted extraction, and ultrasound-assisted extraction, are discussed in this review. Special attention is paid to miniaturized sample preparation methodologies and strategies proposed to reduce organic solvent consumption. Additionally, extraction techniques based on alternative solvents (surfactants, supercritical fluids, or ionic liquids) are also commented in this work, even though these are scarcely used for determination of PBDEs. In addition to liquid-based extraction techniques, solid-based analytical techniques are also addressed. The development of greener, faster and simpler sample preparation approaches has increased in recent years (2003-2013). Among green extraction techniques, those based on the liquid phase predominate over those based on the solid phase (71% vs. 29%, respectively). For solid samples, solvent assisted extraction techniques are preferred for leaching of PBDEs, and liquid phase microextraction techniques are mostly used for liquid samples. Likewise, green characteristics of the instrumental analysis used after the extraction and clean-up steps are briefly discussed. PMID:26755134

  19. Nanobarcoding: detecting nanoparticles in biological samples using in situ polymerase chain reaction

    Directory of Open Access Journals (Sweden)

    Eustaquio T

    2012-11-01

    Full Text Available Trisha Eustaquio, James F LearyWeldon School of Biomedical Engineering, Purdue University, West Lafayette, IN, USABackground: Determination of the fate of nanoparticles (NPs in a biological system, or NP biodistribution, is critical in evaluating an NP formulation for nanomedicine. Current methods to determine NP biodistribution are greatly inadequate, due to their limited detection thresholds. Herein, proof of concept of a novel method for improved NP detection based on in situ polymerase chain reaction (ISPCR, coined “nanobarcoding,” is demonstrated.Methods: Nanobarcoded superparamagnetic iron oxide nanoparticles (NB-SPIONs were characterized by dynamic light scattering, zeta potential, and hyperspectral imaging measurements. Cellular uptake of Cy5-labeled NB-SPIONs (Cy5-NB-SPIONs was imaged by confocal microscopy. The feasibility of the nanobarcoding method was first validated by solution-phase PCR and “pseudo”-ISPCR before implementation in the model in vitro system of HeLa human cervical adenocarcinoma cells, a cell line commonly used for ISPCR-mediated detection of human papilloma virus (HPV.Results: Dynamic light-scattering measurements showed that NB conjugation stabilized SPION size in different dispersion media compared to that of its precursor, carboxylated SPIONs (COOH-SPIONs, while the zeta potential became more positive after NB conjugation. Hyperspectral imaging confirmed NB conjugation and showed that the NB completely covered the SPION surface. Solution-phase PCR and pseudo-ISPCR showed that the expected amplicons were exclusively generated from the NB-SPIONs in a dose-dependent manner. Although confocal microscopy revealed minimal cellular uptake of Cy5-NB-SPIONs at 50 nM over 24 hours in individual cells, ISPCR detected definitive NB-SPION signals inside HeLa cells over large sample areas.Conclusion: Proof of concept of the nanobarcoding method has been demonstrated in in vitro systems, but the technique needs further

  20. Single-step microwave assisted headspace liquid-phase microextraction of trihalomethanes and haloketones in biological samples.

    Science.gov (United States)

    Alsharaa, Abdulnaser; Basheer, Chanbasha; Sajid, Muhammad

    2015-12-15

    A single-step microwave assisted headspace liquid-phase microextraction (MA-HS-LPME) method was developed for determination of trihalomethanes (THMs) and haloketones (HKs) in biological samples. In this method, a porous membrane envelope was filled with few microliters of extraction solvent and then placed inside the microwave extraction vial. A PTFE ring was designed to support the membrane envelope over a certain height inside the vial. An optimum amount of biological sample was placed in the vial equipped with magnetic stirrer. After that nitric acid was added to the vial for digestion of biological sample. The sample was digested and the volatile THMs and HKs were extracted at headspace in the solvent containing porous membrane. After simultaneous digestion and extraction, the extract was injected to gas chromatography/mass spectrometry for analysis. Factors affecting the extraction efficiency were optimized to achieve higher extraction performance. Quantification was carried out over a concentration range of 0.3-100ngg(-1) for brominated compounds while for the chlorinated ones linear range was between 0.5-100ngg(-1). Limit of detections (LODs) were ranged from 0.051 to 0.110ngg(-1) while limit of quantification (LOQ) were in the range of 0.175-0.351ngg(-1). The relative standard deviations (RSDs) of the calibrations were ranged between 1.1 and 6.8%. The MA-HS-LPME was applied for the determination of trace level THMs and HKs in fish tissue and green alga samples. PMID:26571453

  1. Characterization of carbon nanotubes and analytical methods for their determination in environmental and biological samples: A review

    International Nuclear Information System (INIS)

    Highlights: • Analytical techniques for characterization of CNTs: classification, description and examples. • Determination methods for CNTs in biological and environmental samples. • Future trends and perspectives for characterization and determination of CNTs. - Abstract: In the present paper, a critical overview of the most commonly used techniques for the characterization and the determination of carbon nanotubes (CNTs) is given on the basis of 170 references (2000–2014). The analytical techniques used for CNT characterization (including microscopic and diffraction, spectroscopic, thermal and separation techniques) are classified, described, and illustrated with applied examples. Furthermore, the performance of sampling procedures as well as the available methods for the determination of CNTs in real biological and environmental samples are reviewed and discussed according to their analytical characteristics. In addition, future trends and perspectives in this field of work are critically presented

  2. Characterization of carbon nanotubes and analytical methods for their determination in environmental and biological samples: A review

    Energy Technology Data Exchange (ETDEWEB)

    Herrero-Latorre, C., E-mail: carlos.herrero@usc.es; Álvarez-Méndez, J.; Barciela-García, J.; García-Martín, S.; Peña-Crecente, R.M.

    2015-01-01

    Highlights: • Analytical techniques for characterization of CNTs: classification, description and examples. • Determination methods for CNTs in biological and environmental samples. • Future trends and perspectives for characterization and determination of CNTs. - Abstract: In the present paper, a critical overview of the most commonly used techniques for the characterization and the determination of carbon nanotubes (CNTs) is given on the basis of 170 references (2000–2014). The analytical techniques used for CNT characterization (including microscopic and diffraction, spectroscopic, thermal and separation techniques) are classified, described, and illustrated with applied examples. Furthermore, the performance of sampling procedures as well as the available methods for the determination of CNTs in real biological and environmental samples are reviewed and discussed according to their analytical characteristics. In addition, future trends and perspectives in this field of work are critically presented.

  3. Air sampling in the workplace to meet the new part 20 requirements

    International Nuclear Information System (INIS)

    The US Nuclear Regulatory Commission is developing a Regulatory Guide on air sampling in the workplace to meet the requirements of the revised Part 20. The guide will be accompanied by a technical manual describing and giving examples of how to meet the recommendations in the guide. Draft versions of the guide and manual are scheduled to be published for public comment this year. A final guide and manual, revised to consider the public comments, are scheduled to be published in 1992. This talk will summarize some of the more important features of the guide and manual. In particular, the talk will discuss how to demonstrate that samples taken to estimate worker intakes are representative of the air inhaled by workers and what measurements are necessary if a licensee wants to adjust derived air concentrations to account for particle size

  4. Biological sample collection and processing in an on site laboratory in Estonian shale oil mine - BIOMODEM study

    International Nuclear Information System (INIS)

    Full text: The BIOMED-concerted action 'BIOMarkers for Occupational Diesel exhaust Exposure Monitoring (BIOMODEM)' project implied biological sampling from 100 workers of an Estonian shale oil mine. Experiences from pilot studies in Ostrava in Czech Republic and Kotla-Jaerve in Estonia stressed the need of fast processing and storage of biological samples Therefore, in the main study a field laboratory was set up in a building at the mine. Urine samples were collected pre-shift and post-shift after one workday and after 3-4 workdays. Urine samples were separated into 6 aliquots and stored at -200C. Blood samples were collected in CPT-tubes and processed with isolation of lymphocytes, erythrocytes and plasma. The detailed steps in the processing will be presented together with yields of cell populations compared with amount of blood processed. The samples were stored in liquid nitrogen on site and transported on dry ice to laboratories in the United Kingdom, Denmark and Tallinn. The transport of processed samples was taken care of by the project participants to avoid delay with consequent thawing. (author)

  5. A New Sample Substrate for Imaging and Correlating Organic and Trace Metal Composition in Biological Cells and Tissues

    International Nuclear Information System (INIS)

    Many disease processes involve alterations in the chemical makeup of tissue. Synchrotron-based infrared (IR) and X-ray fluorescence (XRF) microscopes are becoming increasingly popular tools for imaging the organic and trace metal compositions of biological materials, respectively, without the need for extrinsic labels or stains. Fourier transform infrared microspectroscopy (FTIRM) provides chemical information on the organic components of a material at a diffraction-limited spatial resolution of 2-10 μm in the mid-infrared region. The synchrotron X-ray fluorescence (SXRF) microprobe is a complementary technique used to probe trace element content in the same systems with a similar spatial resolution. However to be most beneficial, it is important to combine the results from both imaging techniques on a single sample, which requires precise overlap of the IR and X-ray images. In this work, we have developed a sample substrate containing a gold grid pattern on its surface, which can be imaged with both the IR and X-ray microscopes. The substrate consists of a low trace element glass slide that has a gold grid patterned on its surface, where the major and minor parts of the grid contain 25 and 12 nm gold, respectively. This grid pattern can be imaged with the IR microscope because the reflectivity of gold differs as a function of thickness. The pattern can also be imaged with the SXRF microprobe because the Au fluorescence intensity changes with gold thickness. The tissue sample is placed on top of the patterned substrate. The grid pattern's IR reflectivity image and the gold SXRF image are used as fiducial markers for spatially overlapping the IR and SXRF images from the tissue. Results show that IR and X-ray images can be correlated precisely, with a spatial resolution of less than one pixel (i.e., 2-3 microns). The development of this new tool will be presented along with applications to paraffin-embedded metalloprotein crystals, Alzheimer's disease, and hair

  6. Comparison between Monte Carlo simulation and measurement with a 3D polymer gel dosimeter for dose distributions in biological samples

    International Nuclear Information System (INIS)

    In this research, we used a 135 MeV/nucleon carbon-ion beam to irradiate a biological sample composed of fresh chicken meat and bones, which was placed in front of a PAGAT gel dosimeter, and compared the measured and simulated transverse-relaxation-rate (R2) distributions in the gel dosimeter. We experimentally measured the three-dimensional R2 distribution, which records the dose induced by particles penetrating the sample, by using magnetic resonance imaging. The obtained R2 distribution reflected the heterogeneity of the biological sample. We also conducted Monte Carlo simulations using the PHITS code by reconstructing the elemental composition of the biological sample from its computed tomography images while taking into account the dependence of the gel response on the linear energy transfer. The simulation reproduced the experimental distal edge structure of the R2 distribution with an accuracy under about 2 mm, which is approximately the same as the voxel size currently used in treatment planning. (paper)

  7. Comparison between Monte Carlo simulation and measurement with a 3D polymer gel dosimeter for dose distributions in biological samples

    Science.gov (United States)

    Furuta, T.; Maeyama, T.; Ishikawa, K. L.; Fukunishi, N.; Fukasaku, K.; Takagi, S.; Noda, S.; Himeno, R.; Hayashi, S.

    2015-08-01

    In this research, we used a 135 MeV/nucleon carbon-ion beam to irradiate a biological sample composed of fresh chicken meat and bones, which was placed in front of a PAGAT gel dosimeter, and compared the measured and simulated transverse-relaxation-rate (R2) distributions in the gel dosimeter. We experimentally measured the three-dimensional R2 distribution, which records the dose induced by particles penetrating the sample, by using magnetic resonance imaging. The obtained R2 distribution reflected the heterogeneity of the biological sample. We also conducted Monte Carlo simulations using the PHITS code by reconstructing the elemental composition of the biological sample from its computed tomography images while taking into account the dependence of the gel response on the linear energy transfer. The simulation reproduced the experimental distal edge structure of the R2 distribution with an accuracy under about 2 mm, which is approximately the same as the voxel size currently used in treatment planning.

  8. Biologic

    CERN Document Server

    Kauffman, L H

    2002-01-01

    In this paper we explore the boundary between biology and the study of formal systems (logic). In the end, we arrive at a summary formalism, a chapter in "boundary mathematics" where there are not only containers but also extainers ><, entities open to interaction and distinguishing the space that they are not. The boundary algebra of containers and extainers is to biologic what boolean algebra is to classical logic. We show how this formalism encompasses significant parts of the logic of DNA replication, the Dirac formalism for quantum mechanics, formalisms for protein folding and the basic structure of the Temperley Lieb algebra at the foundations of topological invariants of knots and links.

  9. Determining the number of samples required for decisions concerning remedial actions at hazardous waste sites

    International Nuclear Information System (INIS)

    The processing of collecting, analyzing, and assessing the data needed to make to make decisions concerning the cleanup of hazardous waste sites is quite complex and often very expensive. This is due to the many elements that must be considered during remedial investigations. The decision maker must have sufficient data to determine the potential risks to human health and the environment and to verify compliance with regulatory requirements, given the availability of resources allocated for a site, and time constraints specified for the completion of the decision making process. It is desirable to simplify the remedial investigation procedure as much as possible to conserve both time and resources while, simultaneously, minimizing the probability of error associated with each decision to be made. With this in mind, it is necessary to have a practical and statistically valid technique for estimating the number of on-site samples required to ''guarantee'' that the correct decisions are made with a specified precision and confidence level. Here, we will examine existing methodologies and then develop our own approach for determining a statistically defensible sample size based on specific guidelines that have been established for the risk assessment process

  10. Sample size requirements for in situ vegetation and substrate classifications in shallow, natural Nebraska Lakes

    Science.gov (United States)

    Paukert, C.P.; Willis, D.W.; Holland, R.S.

    2002-01-01

    We assessed the precision of visual estimates of vegetation and substrate along transects in 15 shallow, natural Nebraska lakes. Vegetation type (submergent or emergent), vegetation density (sparse, moderate, or dense), and substrate composition (percentage sand, muck, and clay; to the nearest 10%) were estimated at 25-70 sampling sites per lake by two independent observers. Observer agreement for vegetation type was 92%. Agreement ranged from 62.5% to 90.1% for substrate composition. Agreement was also high (72%) for vegetation density estimates. The relatively high agreement between estimates was likely attributable to the homogeneity of the lake habitats. Nearly 90% of the substrate sites were classified as 0% clay, and over 68% as either 0% or 100% sand. When habitats were homogeneous, less than 40 sampling sites per lake were required for 95% confidence that habitat composition was within 10% of the true mean, and over 100 sites were required when habitats were heterogeneous. Our results suggest that relatively high precision is attainable for vegetation and substrate mapping in shallow, natural lakes.

  11. Determination of cobalt in biological samples by line-source and high-resolution continuum source graphite furnace atomic absorption spectrometry using solid sampling or alkaline treatment

    International Nuclear Information System (INIS)

    Two procedures for the determination of Co in biological samples by graphite furnace atomic absorption spectrometry (GF AAS) were compared: solid sampling (SS) and alkaline treatment with tetramethylammonium hydroxide (TMAH) using two different instruments for the investigation: a conventional line-source (LS) atomic absorption spectrometer and a prototype high-resolution continuum source atomic absorption spectrometer. For the direct introduction of the solid samples, certified reference materials (CRM) were ground to a particle size ≤50 μm. Alkaline treatment was carried out by placing about 250 mg of the sample in polypropylene flasks, adding 2 mL of 25% m/v tetramethylammonium hydroxide and de-ionized water. Due to its unique capacity of providing a 3-D spectral plot, a high-resolution continuum source (HR-CS) graphite furnace atomic absorption spectrometry was used as a tool to evaluate potential spectral interferences, including background absorption for both sample introduction procedures, revealing that a continuous background preceded the atomic signal for pyrolysis temperatures lower than 700 deg. C. Molecular absorption bands with pronounced rotational fine structure appeared for atomization temperatures >1800 deg. C probably as a consequence of the formation of PO. After optimization had been carried out using high resolution continuum source atomic absorption spectrometry, the optimized conditions were adopted also for line-source atomic absorption spectrometry. Six biological certified reference materials were analyzed, with calibration against aqueous standards, resulting in agreement with the certified values (according to the t-test for a 95% confidence level) and in detection limits as low as 5 ng g-1

  12. Determination of the Biologically Relevant Sampling Depth for Terrestrial and Aquatic Ecological Risk Assessments (Final Report)

    Science.gov (United States)

    This technical paper provides defensible approximations for what the depth of the biologically active zone, or “biotic zone” is within certain environments. The methods used in this study differ somewhat between Part 1 (Terrestrial Biotic Zone) and Part 2 (Aquatic Biotic Zone). ...

  13. Active Learning Not Associated with Student Learning in a Random Sample of College Biology Courses

    OpenAIRE

    Andrews, T M; Leonard, M. J.; Colgrove, C. A.; Kalinowski, S T

    2011-01-01

    Previous research has suggested that adding active learning to traditional college science lectures substantially improves student learning. However, this research predominantly studied courses taught by science education researchers, who are likely to have exceptional teaching expertise. The present study investigated introductory biology courses randomly selected from a list of prominent colleges and universities to include instructors representing a broader population. We examined the rela...

  14. Active Learning "Not" Associated with Student Learning in a Random Sample of College Biology Courses

    Science.gov (United States)

    Andrews, T. M.; Leonard, M. J.; Colgrove, C. A.; Kalinowski, S. T.

    2011-01-01

    Previous research has suggested that adding active learning to traditional college science lectures substantially improves student learning. However, this research predominantly studied courses taught by science education researchers, who are likely to have exceptional teaching expertise. The present study investigated introductory biology courses…

  15. The use of reference materials in the elemental analysis of biological samples

    International Nuclear Information System (INIS)

    Reference materials (RMs) are useful to compare the accuracy and precision of laboratories and techniques. The desirable properties of biological reference materials are listed, and the problems of production, homogenization and storage described. At present there are only 10 biological RMs available compared with 213 geological and 520 metallurgical RMs. There is a need for more biological RMs including special materials for microprobe analysis and for in vivo activation analysis. A study of 650 mean values for elements in RM Kale, analysed by many laboratories, leads to the following conclusions. 61% of the values lie within +-10% of the best mean, and 80% lie within +-20% of the best mean. Atomic absorption spectrometry gives results that are 5-30% high for seven elements, while intrumental neutron activation analysis gives low and imprecise results for K. Other techniques with poor interlaboratory precision include neutron activation for Mg, polarography for Zn and arc-spectrometry for many elements. More than half the values for elements in Kale were obtained by neutron activation, confirming the importance of this technique and the need for RMs. As a rough estimate, 6 x 109 elemental analyses of biological materials are carried out each year, mostly by medical, agricultural and food scientists. It seems likely that a substantial percentage of these are inaccurate, a situation that might be improved by quality control using standard RMs. (author)

  16. A review of the known biological characteristics of the Great Meteor East site together with a sampling programme for a biological site assessment

    International Nuclear Information System (INIS)

    Existing biological information on GME is reviewed. In common with most other oceanic areas there is very little data available from depths below 2000m. There is virtually no direct benthic information and none at all on the midwater/benthic boundary layer. Existing data from a wider geographic area are relevant to GME but the applicability of such data varies according to the hydrography. A sampling programme is outlined which will allow a comprehensive quantitative and qualitative assessment of the midwater and benthic ecosystems. Particular attention will be paid to the interactions between benthic and midwater communities just above the sea floor. (author)

  17. Validated capillary electrophoretic assays for disaccharide composition analysis of galactosaminoglycans in biologic samples and drugs/nutraceuticals.

    Science.gov (United States)

    Asimakopoulou, Athanasia P; Malavaki, Christina; Afratis, Nikolaos A; Theocharis, Achilleas D; Lamari, Fotini N; Karamanos, Nikos K

    2015-01-01

    Capillary electrophoresis is a separation technique with high resolving power and sensitivity with applications in glycosaminoglycan analysis. In this chapter, we present validated protocols for determining the variously sulfated chondroitin or dermatan sulfate-derived disaccharides. These approaches involve degradation of the polysaccharides with specific chondro/dermato-lyases and electrophoretic analysis with capillary zone electrophoresis in a low pH operating buffer and reversed polarity. This methodology has been applied to drug/nutraceutical formulations or to biologic samples (blood serum, lens capsule) and has been validated. Analysis of biologic tissue samples is often more demanding in terms of detection sensitivity, and thus concentration pretreatment steps and/or a derivatization step with 2-aminoacridone are often advisable. PMID:25325950

  18. Supercritical Fluid Extraction and Ultra Performance Liquid Chromatography of Respiratory Quinones for Microbial Community Analysis in Environmental and Biological Samples

    OpenAIRE

    Koichi Fujie; Hiroyuki Daimon; Yoichi Atsuta; Muhammad Hanif

    2012-01-01

    Microbial community structure plays a significant role in environmental assessment and animal health management. The development of a superior analytical strategy for the characterization of microbial community structure is an ongoing challenge. In this study, we developed an effective supercritical fluid extraction (SFE) and ultra performance liquid chromatography (UPLC) method for the analysis of bacterial respiratory quinones (RQ) in environmental and biological samples. RQ profile analysi...

  19. Cone-beam x-ray phase contrast tomography of biological samples; Optimization of contrast, resolution and field of view

    OpenAIRE

    Bartels, Matthias

    2013-01-01

    Three-dimensional information of entire objects can be obtained by the remarkable technique of computed tomography (CT). In combination with phase sensitive X-ray imaging high contrast for soft tissue structures can be achieved as opposed to CT based on classical radiography. In this work biological samples ranging from micrometer sized single cells over multi-cellular nerve tissue to entire millimeter sized organs are investigated by use of cone-beam propagationbased X-ray phase contrast. Op...

  20. X-ray-induced photo-chemistry and X-ray absorption spectroscopy of biological samples

    OpenAIRE

    George, Graham N.; Pickering, Ingrid J.; Pushie, M. Jake; Nienaber, Kurt; Hackett, Mark J.; Ascone, Isabella; Hedman, Britt; Hodgson, Keith O.; Aitken, Jade B.; Levina, Aviva; Glover, Christopher; Lay, Peter A.

    2012-01-01

    X-ray-induced photo-chemistry of metal sites within biological molecules is a concern for X-ray absorption spectroscopy, X-ray crystallography and other techniques in which samples are illuminated with X-rays. The effects of X-ray-induced photo-chemistry are reviewed and the methods used to mitigate these in X-ray absorption spectroscopy are outlined.

  1. Quantitative and dynamic measurements of biological fresh samples with X-ray phase contrast tomography

    OpenAIRE

    Hoshino, Masato; Uesugi, Kentaro; Tsukube, Takuro; Yagi, Naoto

    2014-01-01

    X-ray phase contrast tomography using a Talbot grating interferometer was applied to biological fresh samples which were not fixed by any fixatives. To achieve a high-throughput measurement for the fresh samples the X-ray phase contrast tomography measurement procedure was improved. The three-dimensional structure of a fresh mouse fetus was clearly depicted as a mass density map using X-ray phase contrast tomography. The mouse fetus measured in the fresh state was then fixed by formalin and m...

  2. The ethics of research on stored biological samples: outcomes of a Workshop.

    Science.gov (United States)

    Vaz, Manjulika; Sridhar, T S; Pai, Sanjay A

    2016-01-01

    Research is often conducted using laboratory samples and data. The ethical issues that arise in a study involving residual samples are considerably different from those arising in a prospective study. Some of these ethical issues concern the risks to confidentiality, individual autonomy, trust in and credibility of the researcher or the research, commercialisation and even the nomenclature involved. PMID:27260824

  3. Conceptual design and sampling procedures of the biological programme of NuukBasic

    DEFF Research Database (Denmark)

    Aastrup, Peter; Nymand, Josephine; Raundrup, Katrine;

    uorescence in three series of plots. Arthropods are sampled by means of yellow pitfall traps as well as in window traps. Microarthropods are sampled in soil cores and extracted in an extractor by gradually heating up soil. The avifauna is monitored with special emphasis on passerine birds. Only few...

  4. Gelatin embedding: a novel way to preserve biological samples for terahertz imaging and spectroscopy

    Science.gov (United States)

    Fan, Shuting; Ung, Benjamin; Parrott, Edward P. J.; Pickwell-MacPherson, Emma

    2015-04-01

    Sample dehydration has traditionally been a challenging problem in ex vivo terahertz biomedical experiments as water content changes significantly affect the terahertz properties and can diminish important contrast features. In this paper, we propose a novel method to prevent sample dehydration using gelatin embedding. By looking at terahertz image data and calculating the optical properties of the gelatin-embedded sample, we find that our method successfully preserves the sample for at least 35 h, both for imaging and spectroscopy. Our novel preservation method demonstrates for the first time the capability to simultaneously maintain sample structural integrity and prevent dehydration at room temperature. This is particularly relevant for terahertz studies of freshly excised tissues but could be beneficial for other imaging and spectroscopy techniques.

  5. Biological Monitoring of human exposure to neonicotinoids using urine samples, and neonicotinoid excretion kinetics

    OpenAIRE

    Harada, Kouji H; Tanaka, Keiko; Sakamoto, Hiroko; Imanaka, Mie; Niisoe, Tamon; Hitomi, Toshiaki; Kobayashi, Hatasu; Okuda, Hiroko; Inoue, Sumiko; Kusakawa, Koichi; Oshima, Masayo; Watanabe, Kiyohiko; Yasojima, Makoto; Takasuga, Takumi; Koizumi, Akio

    2016-01-01

    [Background] Neonicotinoids, which are novel pesticides, have entered into usage around the world because they are selectively toxic to arthropods and relatively non-Toxic to vertebrates. It has been suggested that several neonicotinoids cause neurodevelopmental toxicity in mammals. The aim was to establish the relationship between oral intake and urinary excretion of neonicotinoids by humans to facilitate biological monitoring, and to estimate dietary neonicotinoid intakes by Japanese adults...

  6. Preparation of Biological Samples Containing Metoprolol and Bisoprolol for Applying Methods for Quantitative Analysis

    OpenAIRE

    Corina Mahu Ştefania; Monica Hăncianu; Luminiţa Agoroaei; Anda Cristina Coman Băbuşanu; Elena Butnaru

    2015-01-01

    Arterial hypertension is a complex disease with many serious complications, representing a leading cause of mortality. Selective beta-blockers such as metoprolol and bisoprolol are frequently used in the management of hypertension. Numerous analytical methods have been developed for the determination of these substances in biological fluids, such as liquid chromatography coupled with mass spectrometry, gas chromatography coupled with mass spectrometry, high performance liquid chromatography. ...

  7. Estimating the biological value of soft-bottom sediments with sediment profile imaging and grab sampling

    OpenAIRE

    Van Hoey, G.; Birchenough, S.N.R.; Hostens, K.

    2014-01-01

    Biological value estimation is based on a set of assessment questions and several thresholds to delineate areas of ecological importance (e.g. biodiversity). An existing framework, that was specifically designed to assess the ecosystem biodiversity, was expanded by adding new questions on the productivity, functionality and biogeochemical status of benthic habitats. The additional ecological and sedimentological information was collected by using sediment profile imagery (SPI) and grab sampli...

  8. Nanotherapeutics with anthracyclines: methods of determination and quantification of anthracyclines in biological samples

    Czech Academy of Sciences Publication Activity Database

    Koziolová, Eva; Janoušková, Olga; Chytil, Petr; Studenovský, Martin; Kostka, Libor; Etrych, Tomáš

    2015-01-01

    Roč. 64, Suppl. 1 (2015), S1-S10. ISSN 0862-8408 R&D Projects: GA MŠk(CZ) EE2.3.30.0029; GA MŠk(CZ) ED1.1.00/02.0109 Institutional support: RVO:61389013 Keywords : anthracycline * nanocarrier * quantification Subject RIV: EB - Genetics ; Molecular Biology Impact factor: 1.293, year: 2014 http://www.biomed.cas.cz/physiolres/pdf/64%20Suppl%201/64_S1.pdf

  9. Stability of heroin, 6-monoacetylmorphine, and morphine in biological samples and validation of an LC-MS assay for delayed analyses of pharmacokinetic samples in rats.

    Science.gov (United States)

    Jones, Jessica M; Raleigh, Michael D; Pentel, Paul R; Harmon, Theresa M; Keyler, Daniel E; Remmel, Rory P; Birnbaum, Angela K

    2013-02-23

    Degradation of heroin to 6-monoacetylmorphine (6-MAM) and then morphine happens rapidly in vivo and in vitro. The rates of heroin and 6-MAM degradation depend on the type of biological samples, and the duration and conditions of storage. In order to optimize conditions for measuring heroin and its metabolites in samples collected for pharmacokinetic studies in rats, we investigated the time course of degradation of heroin, 6-MAM, and morphine in four biological matrices: rat blood, rat brain homogenate, bovine serum, and human plasma under various conditions. Analyte concentrations were measured by LC-MS. The goal was to identify conditions that allow maximum flexibility in scheduling sample collection and analysis, as well as gain more information on the stability of heroin in blood and tissue samples. A solid-phase extraction method with ice-cold solvents, sodium fluoride (NaF) and a low pH (3.0) maintained sample stability. Quality controls were within 94.0-105% of the target value. Variability was 4.0-8.9% for all analytes within the range of 5-200 ng/mL for heroin, 5-1000 ng/mL for 6-MAM, and 10-200 ng/mL for morphine. Heroin degradation to 6-MAM was faster in rat whole blood than in plasma, and faster in rat plasma than in rat brain homogenate. Maintaining NaF at 4 mg/mL throughout processing enhanced stability; higher NaF concentrations added to whole blood caused hemolysis. Samples processed through solid phase extraction and stored as dried pellets at 80°C constituted the most stable environment for heroin, and was superior to the storing of samples in solution prior to or after extraction. Nevertheless, post-extraction heroin and 6-MAM levels declined by 6.7-8.3% over one week in rat plasma under these conditions, and by <1-4.7% in bovine serum or human plasma. PMID:23245263

  10. Assessment of beta-emitter radionuclides in biological samples using liquid scintillation counting. Application to the study of internal doses in molecular and cellular biology techniques

    International Nuclear Information System (INIS)

    The radioisotopic techniques used in Molecular and Cellular Biology involve external and internal irradiation risk. It is necessary to control the possible internal contamination associated to the development of these techniques. The internal contamination risk can be due to physical and chemical properties of the labelled compounds, aerosols generated during the performance technique. The aim of this work was to estimate the possible intake of specific beta emitters during the technique development and to propose the required criterions to perform Individual Monitoring. The most representative radioisotopic techniques were selected attending their potential risk of internal contamination. Techniques were analysed applying IAEA methodology according to the used activity in each technique. It was necessary to identify the worker groups that would require individual monitoring on the base of their specific risk. Different measurement procedures were applied to study the possible intake in group risk and more than 160 persons were measured by in vitro bioassay. (Author) 96 refs

  11. Environmental contaminants in water, sediment and biological samples from Playa Lakes in southeastern New Mexico - 1992

    Data.gov (United States)

    US Fish and Wildlife Service, Department of the Interior — Sediment, water, bird tissue, and invertebrates were collected from 10 playa lakes in Southeastern New Mexico in 1991 and 1992. These samples were analyzed for a...

  12. Study of performance characteristics of a radiochemical method to determine uranium in biological samples

    International Nuclear Information System (INIS)

    In this paper is described a methodology to calculate detection limit (Ld), quantification level (Lq) and minimum detectable activity (MDA) in a radiochemical method for determination of uranium in urine samples. The concentration is measured by fluorimetry and alpha gross activity using liquid scintillation counting (LSC). The calculation of total propagated uncertainty on a spike sample is presented. Furthermore, the major sources of uncertainty and percentage contribution in both measurements are assessed. (author)

  13. Two-dimensional SDS-PAGE fractionation of biological samples for biomarker discovery

    OpenAIRE

    Rabilloud, Thierry; Triboulet, Sarah

    2013-01-01

    Two-dimensional electrophoresis is still a very valuable tool in proteomics, due to its reproducibility and its ability to analyze complete proteins. However, due to its sensitivity to dynamic range issues, its most suitable use in the frame of biomarker discovery is not on very complex fluids such as plasma, but rather on more proximal, simpler fluids such as CSF, urine, or secretome samples. Here, we describe the complete workflow for the analysis of such dilute samples by two-dimensional e...

  14. Protease inhibitors as possible pitfalls in proteomic analyses of complex biological samples

    OpenAIRE

    Clifton, James; Huang, Feilei; Rucevic, Marijana; Cao, Lulu; Hixson, Douglas; Josic, Djuro

    2011-01-01

    Sample preparation, especially protein and peptide fractionation prior to identification by mass spectrometry (MS) are typically applied to reduce sample complexity. The second key element in this process is proteolytic digestion that is performed mostly by trypsin. Optimization of this step is an important factor in order to achieve both speed and better performance of proteomic analysis, and tryptic digestion prior to the MS analysis is topic of many studies. To date, only few studies pay a...

  15. Integrating clinical and biological information in a shanghai biobank: an introduction to the sample repository and information sharing platform project.

    Science.gov (United States)

    Cui, Wenbin; Zheng, Peiyong; Yang, Jiahong; Zhao, Rong; Gao, Jiechun; Yu, Guangjun

    2015-02-01

    Biobanks are important resources and central tools for translational medicine, which brings scientific research outcomes to clinical practice. The key purpose of biobanking in translational medicine and other medical research is to provide biological samples that are integrated with clinical information. In 2008, the Shanghai Municipal Government launched the "Shanghai Tissue Bank" in an effort to promote research in translational medicine. Now a sharing service platform has been constructed to integrate clinical practice and biological information that can be used in diverse medical and pharmaceutical research studies. The platform collects two kinds of data: sample data and clinical data. The sample data are obtained from the hospital biobank management system, and mainly include the donors' age, gender, marital status, sample source, sample type, collection time, deposit time, and storage method. The clinical data are collected from the "Hospital-Link" system (a medical information sharing system that connects 23 tertiary hospitals in Shanghai). The main contents include donors' corresponding medication information, test reports, inspection reports, and hospital information. As of the end of September 2014, the project has a collection of 16,020 donors and 148,282 samples, which were obtained from 12 medical institutions, and automatically acquired donors' corresponding clinical data from the "Hospital-Link" system for 6830 occurrences. This project will contribute to scientific research at medical institutions in Shanghai, and will also support the development of the biopharmaceutical industry. In this article, we will describe the significance, the construction phases, the application prospects, and benefits of the sample repository and information sharing service platform. PMID:25686046

  16. The scope of detector Medipix2 in micro-radiography of biological samples

    Czech Academy of Sciences Publication Activity Database

    Dammer, J.; Weyda, František; Jakůbek, J.; Škrabal, P.; Sopko, V.; Vavřík, D.

    2011-01-01

    Roč. 633, č. 1 (2011), s. 175-176. ISSN 0168-9002. [International Workshop on Radiation Imaging Detector s /11./. Praha, 29.06.2009-03.07.2009] R&D Projects: GA MŠk 2B06005 Grant ostatní: Ministerstvo školství(CZ) 6840770040; GA MŠk(CZ) 1P04LA211; GA MŠk(CZ) LC06041 Institutional research plan: CEZ:AV0Z50070508 Keywords : x-ray imaging * digital radiography * photon and x-ray detector s Subject RIV: EA - Cell Biology Impact factor: 1.207, year: 2011

  17. Supercritical fluid extraction and ultra performance liquid chromatography of respiratory quinones for microbial community analysis in environmental and biological samples.

    Science.gov (United States)

    Hanif, Muhammad; Atsuta, Yoichi; Fujie, Koichi; Daimon, Hiroyuki

    2012-01-01

    Microbial community structure plays a significant role in environmental assessment and animal health management. The development of a superior analytical strategy for the characterization of microbial community structure is an ongoing challenge. In this study, we developed an effective supercritical fluid extraction (SFE) and ultra performance liquid chromatography (UPLC) method for the analysis of bacterial respiratory quinones (RQ) in environmental and biological samples. RQ profile analysis is one of the most widely used culture-independent tools for characterizing microbial community structure. A UPLC equipped with a photo diode array (PDA) detector was successfully applied to the simultaneous determination of ubiquinones (UQ) and menaquinones (MK) without tedious pretreatment. Supercritical carbon dioxide (scCO(2)) extraction with the solid-phase cartridge trap proved to be a more effective and rapid method for extracting respiratory quinones, compared to a conventional organic solvent extraction method. This methodology leads to a successful analytical procedure that involves a significant reduction in the complexity and sample preparation time. Application of the optimized methodology to characterize microbial communities based on the RQ profile was demonstrated for a variety of environmental samples (activated sludge, digested sludge, and compost) and biological samples (swine and Japanese quail feces). PMID:22391598

  18. Supercritical Fluid Extraction and Ultra Performance Liquid Chromatography of Respiratory Quinones for Microbial Community Analysis in Environmental and Biological Samples

    Directory of Open Access Journals (Sweden)

    Koichi Fujie

    2012-03-01

    Full Text Available Microbial community structure plays a significant role in environmental assessment and animal health management. The development of a superior analytical strategy for the characterization of microbial community structure is an ongoing challenge. In this study, we developed an effective supercritical fluid extraction (SFE and ultra performance liquid chromatography (UPLC method for the analysis of bacterial respiratory quinones (RQ in environmental and biological samples. RQ profile analysis is one of the most widely used culture-independent tools for characterizing microbial community structure. A UPLC equipped with a photo diode array (PDA detector was successfully applied to the simultaneous determination of ubiquinones (UQ and menaquinones (MK without tedious pretreatment. Supercritical carbon dioxide (scCO2 extraction with the solid-phase cartridge trap proved to be a more effective and rapid method for extracting respiratory quinones, compared to a conventional organic solvent extraction method. This methodology leads to a successful analytical procedure that involves a significant reduction in the complexity and sample preparation time. Application of the optimized methodology to characterize microbial communities based on the RQ profile was demonstrated for a variety of environmental samples (activated sludge, digested sludge, and compost and biological samples (swine and Japanese quail feces.

  19. Development of tomographic reconstruction algorithms for the PIXE analysis of biological samples

    International Nuclear Information System (INIS)

    The development of 3-dimensional microscopy techniques offering a spatial resolution of 1 μm or less has opened a large field of investigation in Cell Biology. Amongst them, an interesting advantage of ion beam micro-tomography is its ability to give quantitative results in terms of local concentrations in a direct way, using Particle Induced X-ray Emission (PIXET) combined to Scanning Transmission Ion Microscopy (STIMT) Tomography. After a brief introduction of existing reconstruction techniques, we present the principle of the DISRA code, the most complete written so far, which is the basis of the present work. We have modified and extended the DISRA algorithm by considering the specific aspects of biologic specimens. Moreover, correction procedures were added in the code to reduce noise in the tomograms. For portability purpose, a Windows graphic interface was designed to easily enter and modify experimental parameters used in the reconstruction, and control the several steps of data reduction. Results of STIMT and PIXET experiments on reference specimens and on human cancer cells will be also presented. (author)

  20. Evaluation of biological samples for specimen banking and biomonitoring by nuclear methods

    International Nuclear Information System (INIS)

    In a pilot program for environmental specimen banking, human livers and marine mussels (Mytilus edulis) were sampled, analyzed and banked. Nuclear methods played a major role in the evaluation of the samples by providing concentration data for up to 37 major, mineral, and trace elements. Instrumental neutron activation analysis was complemented by neutron-capture prompt gamma activation analysis, radiochemical separations and, for the mussels, by instrumental X-ray fluorescence analysis. A cryogenic homogenization procedure was applied for sample preparation and evaluated. Assessment of accuracy was made by analyzing Standard Reference Materials and by intercomparing the techniques. Results are reported for 66 individual human liver specimens, collected at three locations in the United States, and for batches of 65 mussels from a collection made at Narragansett Bay, RI. 19 references, 23 figures, 4 tables

  1. Determination of trace elements in biological samples by inductively coupled plasma mass spectrometry with tetramethylammonium hydroxide solubilization at room temperature.

    Science.gov (United States)

    Batista, Bruno Lemos; Grotto, Denise; Rodrigues, Jairo Lisboa; Souza, Vanessa Cristina de Oliveira; Barbosa, Fernando

    2009-07-30

    A simple method for sample preparation of biological samples for trace elements determination by inductively coupled plasma mass spectrometry (ICP-MS) is described. Prior to analysis, 75 mg of the biological samples were accurately weighed into (15 mL) conical tubes. Then, 1 mL of 50% (v/v) tetramethylammonium hydroxide (TMAH) solution was added to the samples, incubated at room temperature for 12 h and the volume made up to 10 mL with a solution containing 0.5% (v/v) HNO(3), 0.01% (v/v) Triton X-100 and 10 microg L(-1) of Rh. After preparation samples may be stored at -20 degrees C during 3 days until the analysis by ICP-MS. With these conditions, the use of the dynamic reaction cell was only mandatory for chromium determination. Method detection limits were 0.2145, 0.0020, 0.0051, 0.0017, 0.0027, 0.0189, 0.02, 0.5, 0.1, 0.0030, 0.0043, 0.0066, 0.0009, 0.020, 0.0043, 0.1794, 0.1 microg(-1) for Al, As, Ba, Cd, Co, Cr, Cu, Fe, Mg, Mn, Mo, Pb, Sb, Se, Sr, V and Zn, respectively. Validation data are provided based on the analysis of six certified reference materials (CRMs) purchased from the National Institute of Standards and Technology (NIST) and National Research Council Canada (NRCC). Additional validation was provided by the analysis of brain, kidney, liver and heart samples collected from rats and analyzed by the proposed method and by using microwave digestion. PMID:19523552

  2. Estimating risk at a Superfund site using passive sampling devices as biological surrogates in human health risk models

    OpenAIRE

    Allan, Sarah E.; Sower, Gregory J.; Anderson, Kim A.

    2011-01-01

    Passive sampling devices (PSDs) sequester the freely dissolved fraction of lipophilic contaminants, mimicking passive chemical uptake and accumulation by biomembranes and lipid tissues. Public Health Assessments that inform the public about health risks from exposure to contaminants through consumption of resident fish are generally based on tissue data, which can be difficulties to obtain and requires destructive sampling. The purpose of this study is to apply PSD data in a Public Health Ass...

  3. Phase microscopy of technical and biological samples through random phase modulation with a difuser

    DEFF Research Database (Denmark)

    Almoro, Percival; Pedrini, Giancarlo; Gundu, Phanindra Narayan; Osten, Wolfgang; Hanson, Steen Grüner

    2010-01-01

    A technique for phase microscopy using a phase diffuser and a reconstruction algorithm is proposed. A magnified specimen wavefront is projected on the diffuser plane that modulates the wavefront into a speckle field. The speckle patterns at axially displaced planes are sampled and used in an iter...

  4. Development of a radioimmunoassay for the determination of buprenorphine in biological samples

    International Nuclear Information System (INIS)

    The development of a specific and sensitive radioimmunoassay for the detection of buprenorphine in urine samples is described. With minor adjustments, the assay was also applied to the analysis for buprenorphine in plasma samples. The 2-diazobenzoic acid derivative of buprenorphine has been prepared as a hapten. The immunization of rabbits with the hapten-bovine serum albumin conjugate resulted in the production of antibodies, which cross-reacted with N-dealkylbuprenophine up to about the 90% level. The antibodies showed very low cross-reactivities with the 3-O-glucuronides and with the structural analogue etorphine. The assay was mainly used to prescreen for buprenorphine in urine samples of persons suspected of Temgesic misuse and to determine buprenorphine in plasma samples. A linear calibration graph for buprenorphine was obtained after logit-log regression. The spiking recovery study showed a linear regression. Intra-and inter-assay relative standard deviations were -1 (Student's t-distribution, p 0.01, degrees of freedom = 8). (Author)

  5. Analysis of mercury and selenium in biological samples by neutron activation analysis

    International Nuclear Information System (INIS)

    In the present work, hair samples from populations suspected of contamination by mercury, in the localities of Serra do Navio, Vila Nova and Tartarugalzinho, in the State of Amapa, were analyzed. Hair samples of children under odontopediatric treatment were also analyzed for mercury, in order to study the possibility of transfer of mercury from the dental amalgam and also to obtain data of hair mercury in a control population of children. Another step of the work was the development of a method for the determination of selenium, by using the short-lived radioisotope 77mSe. After the certification of the method it was applied to the analysis of hair, nails and a vitamin supplement. A comparison was made with the results obtain ed by using the long-lived radioisotope of selenium, 75Se. The results obtained for mercury in the hair samples of populations living in the State of Amapa have shown that the mercury concentrations in these populations are much higher than in the controls. As for the hair samples of children under treatment with mercury amalgam, no significant differences were found in the concentrations of mercury after the treatment. On the other hand, these data were important to obtain data for a control population of children. The results obtained by using the radioisotope 77mSe showed that the method developed was suitable for the analyzed matrixes and the results were similar to the ones obtained by employing the usual AANI method, with the radioisotope 75Se. (author)

  6. Direct analysis of environmental and biological samples for total mercury with comparison of sequential atomic absorption and fluorescence measurements from a single combustion event

    International Nuclear Information System (INIS)

    A Direct Mercury Analyzer (DMA) based on sample combustion, concentration of mercury by amalgamation with gold, and cold vapor atomic absorption spectrometry (CVAAS) was coupled to a mercury-specific cold vapor atomic fluorescence spectrometer (CVAFS). The purpose was to evaluate combustion-AFS, a technique which is not commercially available, for low-level analysis of mercury in environmental and biological samples. The experimental setup allowed for comparison of dual measurements of mercury (AAS followed by AFS) for a single combustion event. The AFS instrument control program was modified to properly time capture of mercury from the DMA, avoiding deleterious combustion products from reaching its gold traps. Calibration was carried out using both aqueous solutions and solid reference materials. The absolute detection limits for mercury were 0.002 ng for AFS and 0.016 ng for AAS. Recoveries for reference materials ranged from 89% to 111%, and the precision was generally found to be <10% relative standard deviation (RSD). The two methods produced similar results for samples of hair, finger nails, coal, soil, leaves and food stuffs. However, for samples with mercury near the AAS detection limit (e.g., filter paper spotted with whole blood and segments of tree rings) the signal was still quantifiable with AFS, demonstrating the lower detection limit and greater sensitivity of AFS. This study shows that combustion-AFS is feasible for the direct analysis of low levels of mercury in solid samples that would otherwise require time-consuming and contamination-prone digestion.

  7. Development of a micro-XRF system for biological samples based on proton-induced quasimonochromatic X-rays

    International Nuclear Information System (INIS)

    We have developed a micro-XRF system based on a proton-induced quasimonochromatic X-ray (QMXR) microbeam for in vivo measurement of biological samples. A 2.5-MeV proton beam impinged normally on a Cu foil target that was slightly thicker than the proton range. The emitted QMXR behind the Cu target was focused with a polycapillary X-ray half lens. For application to analysis of wet or aquatic samples, we prepared a QMXR beam with an incident angle of 45° with respect to the horizontal plane by using a dipole magnet in order to bend the primary proton beam downward by 45°. The focal spot size of the QMXR microbeam on a horizontal sample surface was evaluated to be 250 × 350 μm by a wire scanning method. A microscope camera with a long working distance was installed perpendicular to the sample surface to identify the analyzed position on the sample. The fluorescent radiation from the sample was collected by a Si-PIN photodiode X-ray detector. Using the setup above, we were able to successfully measure the accumulation and distribution of Co in the leaves of a free-floating aquatic plant on a dilute Co solution surface

  8. Development of a micro-XRF system for biological samples based on proton-induced quasimonochromatic X-rays

    Science.gov (United States)

    Ploykrachang, K.; Hasegawa, J.; Kondo, K.; Fukuda, H.; Oguri, Y.

    2014-07-01

    We have developed a micro-XRF system based on a proton-induced quasimonochromatic X-ray (QMXR) microbeam for in vivo measurement of biological samples. A 2.5-MeV proton beam impinged normally on a Cu foil target that was slightly thicker than the proton range. The emitted QMXR behind the Cu target was focused with a polycapillary X-ray half lens. For application to analysis of wet or aquatic samples, we prepared a QMXR beam with an incident angle of 45° with respect to the horizontal plane by using a dipole magnet in order to bend the primary proton beam downward by 45°. The focal spot size of the QMXR microbeam on a horizontal sample surface was evaluated to be 250 × 350 μm by a wire scanning method. A microscope camera with a long working distance was installed perpendicular to the sample surface to identify the analyzed position on the sample. The fluorescent radiation from the sample was collected by a Si-PIN photodiode X-ray detector. Using the setup above, we were able to successfully measure the accumulation and distribution of Co in the leaves of a free-floating aquatic plant on a dilute Co solution surface.

  9. Development of a micro-XRF system for biological samples based on proton-induced quasimonochromatic X-rays

    Energy Technology Data Exchange (ETDEWEB)

    Ploykrachang, K., E-mail: ploykrachang.k.aa@m.titech.ac.jp [Research Laboratory for Nuclear Reactors, Tokyo Institute of Technology, 2-12-1 Ookayama, Meguro-ku, Tokyo 152-8550 (Japan); Hasegawa, J. [Department of Energy Sciences, Interdisciplinary Graduate School of Science and Engineering, Tokyo Institute of Technology, 4259 Nagatsuta-cho, Midori-ku, Yokohama 226-8502 (Japan); Kondo, K.; Fukuda, H.; Oguri, Y. [Research Laboratory for Nuclear Reactors, Tokyo Institute of Technology, 2-12-1 Ookayama, Meguro-ku, Tokyo 152-8550 (Japan)

    2014-07-15

    We have developed a micro-XRF system based on a proton-induced quasimonochromatic X-ray (QMXR) microbeam for in vivo measurement of biological samples. A 2.5-MeV proton beam impinged normally on a Cu foil target that was slightly thicker than the proton range. The emitted QMXR behind the Cu target was focused with a polycapillary X-ray half lens. For application to analysis of wet or aquatic samples, we prepared a QMXR beam with an incident angle of 45° with respect to the horizontal plane by using a dipole magnet in order to bend the primary proton beam downward by 45°. The focal spot size of the QMXR microbeam on a horizontal sample surface was evaluated to be 250 × 350 μm by a wire scanning method. A microscope camera with a long working distance was installed perpendicular to the sample surface to identify the analyzed position on the sample. The fluorescent radiation from the sample was collected by a Si-PIN photodiode X-ray detector. Using the setup above, we were able to successfully measure the accumulation and distribution of Co in the leaves of a free-floating aquatic plant on a dilute Co solution surface.

  10. A Sensitive Cell-Based Assay to Measure the Doxycycline Concentration in Biological Samples

    NARCIS (Netherlands)

    W. Kleibeuker; X. Zhou; M. Centlivre; N. Legrand; M. Page; N. Almond; B. Berkhout; A.T. Das

    2009-01-01

    Doxycycline (DOX) is widely used as a pharmacological agent and as an effector molecule in inducible gene expression systems. For most applications, it is important to determine whether the DOX concentration reaches the level required for optimal efficacy. We developed a sensitive bioassay for measu

  11. Determination of lead in biological samples of children with different physiological consequences using cloud point extraction method.

    Science.gov (United States)

    Shah, Faheem; Kazi, Tasneem Gul; Ullah, Naeem; Afridi, Hassan Imran

    2013-06-01

    In present study, lead (Pb) level in biological samples of children with physiological disorders (liver, bone, and gastrointestinal; age ranged 1-10 years) have been assessed. For comparison purpose, age-matched healthy children were also selected. Cloud point extraction (CPE) was employed for preconcentration of Pb in acid-digested biological samples prior to its determination by flame atomic absorption spectrometry (FAAS). Dithizone (diphenylthiocarbazone) and nonionic surfactant Triton X-114 (TX-114) were used as complexing reagent and extractant, respectively. The effects of several experimental variables on proposed CPE were evaluated. Under the optimum experimental conditions, the observed detection limit (LOD) and the enhancement factor (EF) were 0.08 μg L(-1) and 53, respectively. Relative standard deviation (RSD) of 10 μg L(-1) Pb was 3.4 %. It was observed that children with liver-, bone-, and gastrointestinal-related disorders had three- to fourfold higher Pb level in blood and scalp hair samples. PMID:23625698

  12. Interaction of cadmium and zinc in biological samples of smokers and chewing tobacco female mouth cancer patients

    Energy Technology Data Exchange (ETDEWEB)

    Kazi, Tasneem Gul, E-mail: tgkazi@yahoo.com [National Center of Excellence in Analytical Chemistry, University of Sindh, Jamshoro 76080 (Pakistan); Wadhwa, Sham Kumar, E-mail: wadhwashamkumar@yahoo.com [National Center of Excellence in Analytical Chemistry, University of Sindh, Jamshoro 76080 (Pakistan); Afridi, Hassan Imran, E-mail: hassanimranafridi@yahoo.com [National Center of Excellence in Analytical Chemistry, University of Sindh, Jamshoro 76080 (Pakistan); Kazi, Naveed, E-mail: tgkazi@yahoo.com [Liaquat University of Medical and Health Sciences, Jamshoro 76080 (Pakistan); Kandhro, Ghulam Abbas [National Center of Excellence in Analytical Chemistry, University of Sindh, Jamshoro 76080 (Pakistan); Baig, Jamil Ahmed, E-mail: jab_mughal@yahoo.com [National Center of Excellence in Analytical Chemistry, University of Sindh, Jamshoro 76080 (Pakistan); Shah, Abdul Qadir, E-mail: aqshah07@yahoo.com [National Center of Excellence in Analytical Chemistry, University of Sindh, Jamshoro 76080 (Pakistan); Kolachi, Nida Fatima [National Center of Excellence in Analytical Chemistry, University of Sindh, Jamshoro 76080 (Pakistan); Arain, Muhammad Balal, E-mail: bilal_ku2004@yahoo.com [Department of Mathematics and Basic Sciences, NED University of Engineering and Technology, Karachi 75270 (Pakistan)

    2010-04-15

    Epidemiologic studies suggest that zinc (Zn) deficiency and high accumulation of cadmium (Cd) may be associated with increased risk of cancer. The incidence of mouth cancer has increased among females, who possess habits of chewing tobacco with gradients (areca nut and betel quid) and smoking tobacco in Pakistan. In present study, we measured the concentration of Cd and Zn in 96 mouth cancer patients (MCPs) and 110 female controls/referents (67 smoker and chewing tobacco), while 43 have none of smoking and chewing tobacco habits, belongs to different cities of Pakistan. Both controls and patients have same age group (ranged 35-65 years), socio-economic status, localities and dietary habits. The Zn and Cd were determined by flame/graphite furnace atomic absorption spectrophotometer, prior to microwave assisted acid digestion method. The Cd/Zn ratio in both biological samples was also calculated. The results of this study showed that the mean value of Zn was lower, while the mean concentration of Cd was higher in the blood and scalp hair samples of MCPs as compared to control subjects (p < 0.001). The controls chewing and smoking tobacco have high level of Cd in both biological samples as compared to those have not smoking or chewing tobacco (p < 0.012). The Cd/Zn ratio was higher in MCPs than control subjects. This study is compelling evidence in support of positive associations between cadmium, cigarette smoking, deficiency of Zn and cancer risk.

  13. Sensor structure concepts for the analysis or local radiation exposure of biological samples at terahertz and millimeter wave frequencies

    Science.gov (United States)

    Dornuf, Fabian; Dörr, Roland; Lämmle, David; Schlaak, Helmut F.; Krozer, Viktor

    2016-03-01

    We have studied several sensor concepts for biomedical applications operating in the millimeter wave and terahertz range. On one hand, rectangular waveguide structure were designed and extended with microfluidic channels. In this way a simple analysis of aqueous solutions at various waveguide bands is possible. In our case, we focused on the frequency range between 75 GHz and 110 GHz. On the other hand, planar sensor structures for aqueous solutions have been developed based on coplanar waveguides. With these planar sensors it is possible to concentrate the interaction volume on small sensor areas, which achieve a local exposure of the radiation to the sample. When equipping the sensor with microfluidic structures the sample volume could be reduced significantly and enabled a localized interaction with the sensor areas. The sensors are designed to exhibit a broadband behavior up to 300 GHz. Narrow-band operation can also be achieved for potentially increased sensitivity by using resonant structures. Several tests with Glucose dissolved in water show promising results for the distinction of different glucose levels at millimeter wave frequencies. The planar structures can also be used for the exposure of biological cells or cell model systems like liposomes with electromagnetic radiation. Several studies are planned to distinguish on one hand the influence of millimeter wave exposure on biological systems and also to have a spectroscopic method which enables the analysis of cell processes, like membrane transport processes, with millimeter wave and terahertz frequencies by focusing the electric field directly on the analyzing sample.

  14. Interaction of cadmium and zinc in biological samples of smokers and chewing tobacco female mouth cancer patients

    International Nuclear Information System (INIS)

    Epidemiologic studies suggest that zinc (Zn) deficiency and high accumulation of cadmium (Cd) may be associated with increased risk of cancer. The incidence of mouth cancer has increased among females, who possess habits of chewing tobacco with gradients (areca nut and betel quid) and smoking tobacco in Pakistan. In present study, we measured the concentration of Cd and Zn in 96 mouth cancer patients (MCPs) and 110 female controls/referents (67 smoker and chewing tobacco), while 43 have none of smoking and chewing tobacco habits, belongs to different cities of Pakistan. Both controls and patients have same age group (ranged 35-65 years), socio-economic status, localities and dietary habits. The Zn and Cd were determined by flame/graphite furnace atomic absorption spectrophotometer, prior to microwave assisted acid digestion method. The Cd/Zn ratio in both biological samples was also calculated. The results of this study showed that the mean value of Zn was lower, while the mean concentration of Cd was higher in the blood and scalp hair samples of MCPs as compared to control subjects (p < 0.001). The controls chewing and smoking tobacco have high level of Cd in both biological samples as compared to those have not smoking or chewing tobacco (p < 0.012). The Cd/Zn ratio was higher in MCPs than control subjects. This study is compelling evidence in support of positive associations between cadmium, cigarette smoking, deficiency of Zn and cancer risk.

  15. Correlation of Arsenic Levels in Smokeless Tobacco Products and Biological Samples of Oral Cancer Patients and Control Consumers.

    Science.gov (United States)

    Arain, Sadaf S; Kazi, Tasneem G; Afridi, Hassan I; Talpur, Farah N; Kazi, Atif G; Brahman, Kapil D; Naeemullah; Panhwar, Abdul H; Kamboh, Muhammad A

    2015-12-01

    It has been extensively reported that chewing of smokeless tobacco (SLT) can lead to cancers of oral cavity. In present study, the relationship between arsenic (As) exposure via chewing/inhaling different SLT products in oral cancer patients have or/not consumed SLT products was studied. The As in different types of SLT products (gutkha, mainpuri, and snuff) and biological (scalp hair and blood) samples of different types of oral cancer patients and controls were analyzed. Both controls and oral cancer patients have same age group (ranged 30-60 years), socio-economic status, localities, and dietary habits. The concentrations of As in SLT products and biological samples were measured by electrothermal atomic absorption spectrophotometer after microwave-assisted acid digestion. The validity and accuracy of the methodology were checked by certified reference materials. The resulted data of present study indicates that the concentration of As was significantly higher in scalp hair and blood samples of oral cancer patients than those of controls (p0.01). The intake of As via consuming different SLT may have synergistic effects, in addition to other risk factors associated with oral cancer. PMID:25975948

  16. Computational approaches and metrics required for formulating biologically realistic nanomaterial pharmacokinetic models

    International Nuclear Information System (INIS)

    The field of nanomaterial pharmacokinetics is in its infancy, with major advances largely restricted by a lack of biologically relevant metrics, fundamental differences between particles and small molecules of organic chemicals and drugs relative to biological processes involved in disposition, a scarcity of sufficiently rich and characterized in vivo data and a lack of computational approaches to integrating nanomaterial properties to biological endpoints. A central concept that links nanomaterial properties to biological disposition, in addition to their colloidal properties, is the tendency to form a biocorona which modulates biological interactions including cellular uptake and biodistribution. Pharmacokinetic models must take this crucial process into consideration to accurately predict in vivo disposition, especially when extrapolating from laboratory animals to humans since allometric principles may not be applicable. The dynamics of corona formation, which modulates biological interactions including cellular uptake and biodistribution, is thereby a crucial process involved in the rate and extent of biodisposition. The challenge will be to develop a quantitative metric that characterizes a nanoparticle's surface adsorption forces that are important for predicting biocorona dynamics. These types of integrative quantitative approaches discussed in this paper for the dynamics of corona formation must be developed before realistic engineered nanomaterial risk assessment can be accomplished. (paper)

  17. Computational approaches and metrics required for formulating biologically realistic nanomaterial pharmacokinetic models

    Science.gov (United States)

    Riviere, Jim E.; Scoglio, Caterina; Sahneh, Faryad D.; Monteiro-Riviere, Nancy A.

    2013-01-01

    The field of nanomaterial pharmacokinetics is in its infancy, with major advances largely restricted by a lack of biologically relevant metrics, fundamental differences between particles and small molecules of organic chemicals and drugs relative to biological processes involved in disposition, a scarcity of sufficiently rich and characterized in vivo data and a lack of computational approaches to integrating nanomaterial properties to biological endpoints. A central concept that links nanomaterial properties to biological disposition, in addition to their colloidal properties, is the tendency to form a biocorona which modulates biological interactions including cellular uptake and biodistribution. Pharmacokinetic models must take this crucial process into consideration to accurately predict in vivo disposition, especially when extrapolating from laboratory animals to humans since allometric principles may not be applicable. The dynamics of corona formation, which modulates biological interactions including cellular uptake and biodistribution, is thereby a crucial process involved in the rate and extent of biodisposition. The challenge will be to develop a quantitative metric that characterizes a nanoparticle's surface adsorption forces that are important for predicting biocorona dynamics. These types of integrative quantitative approaches discussed in this paper for the dynamics of corona formation must be developed before realistic engineered nanomaterial risk assessment can be accomplished.

  18. Trace determination of uranium and thorium in biological samples by radiochemical neutron activation analysis

    International Nuclear Information System (INIS)

    Radiochemical neutron activation analysis (RNAA) is an excellent method for determining uranium and thorium; it offers unique possibilities for their ultratrace analysis using selective radiochemical separations. Regarding the favourably sensitive nuclear characteristics of uranium and of thorium with respect to RNAA, but the different half-lives of their induced nuclides, two different approaches were used. In the first approach uranium and thorium were determined separately via 239U, 239Np and 233Pa. In the second approach these elements were 239239233 determined simultaneously in a single sample using U and/or Np and Pa. Isolation of induced nuclides was based on separation by extraction and/or anion exchange chromatography. Chemical yields were measured in each sample aliquot using added 235U, 238Np and 231Pa radioisotopic tracers. (author)

  19. Organochlorine pesticides in sediment and biological samples from the coastal lagoons of Nicaragua

    International Nuclear Information System (INIS)

    A study was carried out on the Pacific coast of Nicaragua to investigate the contamination of the coastal lagoons with residues of agricultural pesticides. Samples were taken during 1995 from the areas of Estero Real, Padre Ramos, Maderas Negras, Naranjo and Paso Caballos, and during 1996 from Aposentillo to Estero Barquito - Posoltega River. Analysis of the samples of sediment and aquatic life (fishes, oysters and bivalves) showed that they were contaminated with organochlorine pesticides. The pesticides found in the highest concentrations were toxaphene (1,734 μg.kg-1) and p,p-DDE (275 μg kg-1). These data indicate widespread contamination of the ecosystem with organochlorine pesticides in the main Pacific coastal lagoons of Nicaragua, resulting from intensive agricultural use of pesticides during the past decades. The contamination has been carried from the agricultural areas to the coastal lagoons by the rivers passing through the cultivated areas. (author)

  20. Replica exchange with solute tempering: A method for sampling biological systems in explicit water

    OpenAIRE

    Liu, Pu; Kim, Byungchan; Friesner, Richard A.; Berne, B. J.

    2005-01-01

    An innovative replica exchange (parallel tempering) method called replica exchange with solute tempering (REST) for the efficient sampling of aqueous protein solutions is presented here. The method bypasses the poor scaling with system size of standard replica exchange and thus reduces the number of replicas (parallel processes) that must be used. This reduction is accomplished by deforming the Hamiltonian function for each replica in such a way that the acceptance probability for the exchang...

  1. Surface plasmon resonance: advances of label-free approaches in the analysis of biological samples

    Czech Academy of Sciences Publication Activity Database

    Riedel, Tomáš; Majek, P.; Rodriguez-Emmenegger, Cesar; Brynda, Eduard

    2014-01-01

    Roč. 6, č. 24 (2014), s. 3325-3336. ISSN 1757-6180 R&D Projects: GA ČR(CZ) GBP205/12/G118; GA MŠk(CZ) EE2.3.30.0029; GA MŠk(CZ) ED1.1.00/02.0109 Institutional support: RVO:61389013 Keywords : surface plasmon resonance sensors * polymer brushes * human serum samples Subject RIV: CE - Biochemistry Impact factor: 3.003, year: 2014

  2. Label-free quantification of Tacrolimus in biological samples by atomic force microscopy

    Energy Technology Data Exchange (ETDEWEB)

    Menotta, Michele, E-mail: michele.menotta@uniurb.it [Department of Biomolecular Sciences, University of Urbino “Carlo Bo” via Saffi 2, Urbino (Italy); Biagiotti, Sara [Department of Biomolecular Sciences, University of Urbino “Carlo Bo” via Saffi 2, Urbino (Italy); Streppa, Laura [Physics Laboratory, CNRS-ENS, UMR 5672, Lyon (France); Cell and Molecular Biology Laboratory, CNRS-ENS Lyon, UMR 5239, IFR128, Lyon (France); Rossi, Luigia; Magnani, Mauro [Department of Biomolecular Sciences, University of Urbino “Carlo Bo” via Saffi 2, Urbino (Italy)

    2015-07-16

    Highlights: • Tacrolimus is a potent immunosuppressant drug that has to be continually monitored. • We present an atomic force microscope approach for quantification of Tacrolimus in blood samples. • Detection and quantification have been successfully achieved. - Abstract: In the present paper we describe an atomic force microscopy (AFM)-based method for the quantitative analysis of FK506 (Tacrolimus) in whole blood (WB) samples. Current reference methods used to quantify this immunosuppressive drug are based on mass spectrometry. In addition, an immunoenzymatic assay (ELISA) has been developed and is widely used in clinic, even though it shows a small but consistent overestimation of the actual drug concentration when compared with the mass spectrometry method. The AFM biosensor presented herein utilises the endogen drug receptor, FKBP12, to quantify Tacrolimus levels. The biosensor was first assayed to detect the free drug in solution, and subsequently used for the detection of Tacrolimus in blood samples. The sensor was suitable to generate a dose–response curve in the full range of clinical drug monitoring. A comparison with the clinically tested ELISA assay is also reported.

  3. Non-target time trend screening: a data reduction strategy for detecting emerging contaminants in biological samples.

    Science.gov (United States)

    Plassmann, Merle M; Tengstrand, Erik; Åberg, K Magnus; Benskin, Jonathan P

    2016-06-01

    Non-targeted mass spectrometry-based approaches for detecting novel xenobiotics in biological samples are hampered by the occurrence of naturally fluctuating endogenous substances, which are difficult to distinguish from environmental contaminants. Here, we investigate a data reduction strategy for datasets derived from a biological time series. The objective is to flag reoccurring peaks in the time series based on increasing peak intensities, thereby reducing peak lists to only those which may be associated with emerging bioaccumulative contaminants. As a result, compounds with increasing concentrations are flagged while compounds displaying random, decreasing, or steady-state time trends are removed. As an initial proof of concept, we created artificial time trends by fortifying human whole blood samples with isotopically labelled standards. Different scenarios were investigated: eight model compounds had a continuously increasing trend in the last two to nine time points, and four model compounds had a trend that reached steady state after an initial increase. Each time series was investigated at three fortification levels and one unfortified series. Following extraction, analysis by ultra performance liquid chromatography high-resolution mass spectrometry, and data processing, a total of 21,700 aligned peaks were obtained. Peaks displaying an increasing trend were filtered from randomly fluctuating peaks using time trend ratios and Spearman's rank correlation coefficients. The first approach was successful in flagging model compounds spiked at only two to three time points, while the latter approach resulted in all model compounds ranking in the top 11 % of the peak lists. Compared to initial peak lists, a combination of both approaches reduced the size of datasets by 80-85 %. Overall, non-target time trend screening represents a promising data reduction strategy for identifying emerging bioaccumulative contaminants in biological samples. Graphical abstract

  4. Evaluating HBsAg rapid test performance for different biological samples from low and high infection rate settings & populations

    OpenAIRE

    Cruz, Helena Medina; Scalioni, Leticia de Paula; de Paula, Vanessa Salete; da Silva, Elisangela Ferreira; do Ó, Kycia Maria Rodrigues; Milagres, Flavio Augusto Pádua; Cruz, Marcelo Santos; Bastos, Francisco Inácio; Pollo-Flores, Priscila; Leal, Erotildes; Motta-Castro, Ana Rita Coimbra; Pilotto, José Henrique; Lewis-Ximenez, Lia Laura; Lampe, Elisabeth; Villar, Livia Melo

    2015-01-01

    Background Rapid tests (RTs) might have several advantages over standard laboratory procedures, increasing access to diagnosis, especially among vulnerable populations and/or those living in remote areas. The aim of this study was to evaluate the performance of RTs for the detection of hepatitis B virus surface antigen (HBsAg) in samples from different populations/settings. Methods Three RTs for HBsAg detection (Vikia® HBsAg, HBsAg Teste Rápido®, and Imuno-Rápido HBsAg®) and different biologi...

  5. High-resolution, high-transmission soft x-ray spectrometer for the study of biological samples

    OpenAIRE

    Heske, C.

    2009-01-01

    We present a variable line-space grating spectrometer for soft s-rays that coverst the photon energy range between 130 and 650 eV. The optical design is based on the Hettrick-Underwood principle and tailored to synchrotron-based studies of radiation-sensitive biological samples. The spectrometer is able to record the entire spectral range in one shot, i.e., without any mechanical motion, at a resolving power of 1200 or better. Despite is slitless design, such a resolving power can be achieved...

  6. High-resolution, high-transmission soft x-ray spectrometer for the study of biological samples

    OpenAIRE

    Fuchs, Oliver

    2010-01-01

    We present a variable line-space grating spectrometer for soft x-rays that covers the photon energy range between 130 and 650 eV. The optical design is based on the Hettrick-Underwood principle and tailored to synchrotron-based studies of radiation-sensitive biological samples. The spectrometer is able to record the entire spectral range in one shot, i.e., without any mechanical motion, at a resolving power of 1200 or better. Despite its slitless design, such a resolving power can be achieved...

  7. Personal air sampling and biological monitoring of occupational exposure to the soil fumigant cis-1,3-dichloropropene

    OpenAIRE

    Brouwer, E.J.; Verplanke, A.J.W.; Boogaard, P J; Bloemen, L.J.; Sittert, van, N.J.; Christian, F.E.; Stokkentreeff, M; Dijksterhuis, A.; Mulder, A.; Wolff, de, F.A.; K¿hler, A.

    2000-01-01

    OBJECTIVES—To assess exposure of commercial application workers to the nematocide cis-1,3-dichloropropene (cis-DCP).
METHODS—The study was conducted during the annual application season, August to 15 November, in the starch potato growing region in The Netherlands. 14 Application workers collected end of shift urine samples on each fumigation day (n=119). The mercapturic acid metabolite N-acetyl-S-(cis-3-chloro-2-propenyl)-L-cysteine (cis-DCP-MA) in urine was used for biological monitoring of...

  8. Applications of High Resolution Laser Induced Breakdown Spectroscopy for Environmental and Biological Samples

    Energy Technology Data Exchange (ETDEWEB)

    Martin, Madhavi Z [ORNL; Labbe, Nicole [ORNL; Wagner, Rebekah J. [Pennsylvania State University, University Park, PA

    2013-01-01

    This chapter details the application of LIBS in a number of environmental areas of research such as carbon sequestration and climate change. LIBS has also been shown to be useful in other high resolution environmental applications for example, elemental mapping and detection of metals in plant materials. LIBS has also been used in phytoremediation applications. Other biological research involves a detailed understanding of wood chemistry response to precipitation variations and also to forest fires. A cross-section of Mountain pine (pinceae Pinus pungen Lamb.) was scanned using a translational stage to determine the differences in the chemical features both before and after a fire event. Consequently, by monitoring the elemental composition pattern of a tree and by looking for abrupt changes, one can reconstruct the disturbance history of a tree and a forest. Lastly we have shown that multivariate analysis of the LIBS data is necessary to standardize the analysis and correlate to other standard laboratory techniques. LIBS along with multivariate statistical analysis makes it a very powerful technology that can be transferred from laboratory to field applications with ease.

  9. Identifying Variables Responsible for Clustering in Discriminant Analysis of Data from Infrared Microspectroscopy of a Biological Sample

    NARCIS (Netherlands)

    Martin, Francis L.; German, Matthew J.; Wit, Ernst; Fearn, Thomas; Ragavan, Narasimhan; Pollock, Hubert M.

    2007-01-01

    In the biomedical field, infrared (IR) spectroscopic studies can involve the processing of data derived from many samples, divided into classes such as category of tissue (e.g., normal or cancerous) or patient identity. We require reliable methods to identify the class-specific information on which

  10. An intercomparison of γ-spectrometry on two samples of biological origin by eight laboratories in four countries

    International Nuclear Information System (INIS)

    This report gives details of the first inter-laboratory comparison of γ-spectrometry to be run within SPERA, the South Pacific Environmental Radioactivity Association since its inauguration in 1991. Laboratories in Australia, Chile, French Polynesia and New Zealand participated in the exercise. Two 'unknown' samples of biological origin were analysed. The first was a sample of milk powder derived from IAEA reference material. This sample provided an assessment of overall accuracy of 134Cs, 137Cs and 40K determinations. The second sample consisted of dried fish flesh including natural 40K and spiked with a mixed nuclide solution containing 210Pb, 109Cd, 54Mn, 60Co and trace 133Ba. Together the samples gave information on analytical precision over a range of energies and activities. When the results were compared with the recommended values and confidence intervals of the IAEA reference material, the overall accuracy of the γ-spectrometry analytical procedures was found to be good. The average mean values for combined laboratory data fell within the recommended value ranges for each isotope. Ninety percent of the individual laboratory isotope mean values were within two standard errors of the 95% confidence interval of the standard, 75% were within 1 s.e., and 33% of the analyses fell within the confidence interval. The largest sources of error were derived from reporting and calculating of results which gave a 16% gross error rate. (Author)

  11. Optimisation of Pt sensitivity in PIXE analysis of thin biological samples

    International Nuclear Information System (INIS)

    To obtain Pt concentration distributions in tumor biopsies, micro-PIXE is used. The limit of detection (LOD) for Pt is determined by the background production cross section together with the production cross section for the Pt-L lines. Both are functions of the type and energy of the projectile. In order to optimise the experimental conditions, the proton energy is varied from 2.5 to 5 MeV and the corresponding X-ray spectra are analysed. The optimum LOD is about 1 μg/g for a sample thickness of 1 mg/cm2 and a total charge of 100 μC. A study is performed to investigate the possibility of elemental analysis by means of α excitation. The corresponding LOD is 6 μg/g with 200 μC charge (He++ was used). For α excitation, sample damage limits the beam current and, thus, causes a tremendous increase in the measurement time. (orig.)

  12. 3-Dimensional quantitative detection of nanoparticle content in biological tissue samples after local cancer treatment

    Energy Technology Data Exchange (ETDEWEB)

    Rahn, Helene, E-mail: helene.rahn@gmail.com [Institute of Fluid Mechanics, Chair of Magnetofluiddynamics, Technische Universitaet Dresden, Dresden 01069 (Germany); Alexiou, Christoph [ENT-Department, Section for Experimental Oncology and Nanomedicine (Else Kröner-Fresenius-Stiftungsprofessur), University Hospital Erlangen, Waldstraße 1, Erlangen 91054 (Germany); Trahms, Lutz [Physikalisch-Technische Bundesanstalt, Abbestraße 2-12, Berlin 10587 (Germany); Odenbach, Stefan [Institute of Fluid Mechanics, Chair of Magnetofluiddynamics, Technische Universitaet Dresden, Dresden 01069 (Germany)

    2014-06-01

    X-ray computed tomography is nowadays used for a wide range of applications in medicine, science and technology. X-ray microcomputed tomography (XµCT) follows the same principles used for conventional medical CT scanners, but improves the spatial resolution to a few micrometers. We present an example of an application of X-ray microtomography, a study of 3-dimensional biodistribution, as along with the quantification of nanoparticle content in tumoral tissue after minimally invasive cancer therapy. One of these minimal invasive cancer treatments is magnetic drug targeting, where the magnetic nanoparticles are used as controllable drug carriers. The quantification is based on a calibration of the XµCT-equipment. The developed calibration procedure of the X-ray-µCT-equipment is based on a phantom system which allows the discrimination between the various gray values of the data set. These phantoms consist of a biological tissue substitute and magnetic nanoparticles. The phantoms have been studied with XµCT and have been examined magnetically. The obtained gray values and nanoparticle concentration lead to a calibration curve. This curve can be applied to tomographic data sets. Accordingly, this calibration enables a voxel-wise assignment of gray values in the digital tomographic data set to nanoparticle content. Thus, the calibration procedure enables a 3-dimensional study of nanoparticle distribution as well as concentration. - Highlights: • Local cancer treatments are promising in reducing negative side effects occurring during conventional chemotherapy. • The nanoparticles play an important role in delivering drugs to the designated area during local cancer treatments as magnetic drug targeting. • We study the nanoparticles distribution in tumor tissue after magnetic drug targeting with X-ray computed tomography. • We achieved a 3-dimensional quantification of the nanoparticles content in tumor tissue out of digital tomographic data.

  13. Photonic Crystal Optical Tweezers with High Efficiency for Live Biological Samples and Viability Characterization

    Science.gov (United States)

    Jing, Peifeng; Wu, Jingda; Liu, Gary W.; Keeler, Ethan G.; Pun, Suzie H.; Lin, Lih Y.

    2016-01-01

    We propose and demonstrate a new optical trapping method for single cells that utilizes modulated light fields to trap a wide array of cell types, including mammalian, yeast, and Escherichia coli cells, on the surface of a two-dimensional photonic crystal. This method is capable of reducing the required light intensity, and thus minimizing the photothermal damage to living cells, thereby extending cell viability in optical trapping and cell manipulation applications. To this end, a thorough characterization of cell viability in optical trapping environments was performed. This study also demonstrates the technique using spatial light modulation in patterned manipulation of live cell arrays over a broad area.

  14. High-resolution, high-transmission soft x-ray spectrometer for the study of biological samples.

    Science.gov (United States)

    Fuchs, O; Weinhardt, L; Blum, M; Weigand, M; Umbach, E; Bär, M; Heske, C; Denlinger, J; Chuang, Y-D; McKinney, W; Hussain, Z; Gullikson, E; Jones, M; Batson, P; Nelles, B; Follath, R

    2009-06-01

    We present a variable line-space grating spectrometer for soft x-rays that covers the photon energy range between 130 and 650 eV. The optical design is based on the Hettrick-Underwood principle and tailored to synchrotron-based studies of radiation-sensitive biological samples. The spectrometer is able to record the entire spectral range in one shot, i.e., without any mechanical motion, at a resolving power of 1200 or better. Despite its slitless design, such a resolving power can be achieved for a source spot as large as (30 x 3000) microm2, which is important for keeping beam damage effects in radiation-sensitive samples low. The high spectrometer efficiency allows recording of comprehensive two-dimensional resonant inelastic soft x-ray scattering (RIXS) maps with good statistics within several minutes. This is exemplarily demonstrated for a RIXS map of highly oriented pyrolytic graphite, which was taken within 10 min. PMID:19566192

  15. High-resolution, high-transmission soft x-ray spectrometer for the study of biological samples

    International Nuclear Information System (INIS)

    We present a variable line-space grating spectrometer for soft x-rays that covers the photon energy range between 130 and 650 eV. The optical design is based on the Hettrick-Underwood principle and tailored to synchrotron-based studies of radiation-sensitive biological samples. The spectrometer is able to record the entire spectral range in one shot, i.e., without any mechanical motion, at a resolving power of 1200 or better. Despite its slitless design, such a resolving power can be achieved for a source spot as large as (30x3000) μm2, which is important for keeping beam damage effects in radiation-sensitive samples low. The high spectrometer efficiency allows recording of comprehensive two-dimensional resonant inelastic soft x-ray scattering (RIXS) maps with good statistics within several minutes. This is exemplarily demonstrated for a RIXS map of highly oriented pyrolytic graphite, which was taken within 10 min.

  16. k0-INAA application at IPEN Neutron Activation Laboratory by using the k0-IAEA program: biological sample analysis

    International Nuclear Information System (INIS)

    The results obtained in the application of the k0-standardization method at LAN-IPEN for biological matrices analysis, by using the k0-IAEA software, provided by the International Atomic Energy Agency (IAEA), are presented. The flux parameters f and a of the IEA-R1 reactor were determined for the pneumatic irradiation facility and for one selected irradiation position, 24B/shelf2, for short and long irradiations, respectively. In order to obtain these parameters, the bare triple-monitor method with 197Au-96Zr-94Zr was used. In order to evaluate the accuracy and precision of the methodology, the biological reference materials Peach Leaves (NIST SRM 1547), Mixed Polish Herbs (INCT-MPH-2) e Tomato Leaves (NIST SRM 1573a) were analyzed. The statistical criteria Relative Errors (bias, %), Coefficient of Variation (CV) and U-score were applied to the obtained results (mean of six replicates). The relative errors (bias, %) in relation to certified values, were, for most elements, in the range of 0 e 30. The Coefficients of Variation were below 20%, showing a good reproducibility of the results. The U-score test showed that all results, except Na in Peach Leaves and in Tomato Leaves, were within 95% confidence interval. These results point out to a promising use of the k0-INAA method at LAN-IPEN for biological sample analysis. (author)

  17. Determination and validation of the elastic moduli of small and complex biological samples: bone and keratin in bird beaks.

    Science.gov (United States)

    Soons, Joris; Herrel, Anthony; Aerts, Peter; Dirckx, Joris

    2012-06-01

    In recent years, there has been a surge in the development of finite-element (FE) models aimed at testing biological hypotheses. For example, recent modelling efforts suggested that the beak in Darwin's finches probably evolved in response to fracture avoidance. However, knowledge of the material properties of the structures involved is crucial for any model. For many biological structures, these data are not available and may be difficult to obtain experimentally given the complex nature of biological structures. Beaks are interesting as they appear to be highly optimized in some cases. In order to understand the biomechanics of this small and complex structure, we have been developing FE models that take into account the bilayered structure of the beak consisting of bone and keratin. Here, we present the results of efforts related to the determination and validation of the elastic modulus of bone and keratin in bird beaks. The elastic moduli of fresh and dried samples were obtained using a novel double-indentation technique and through an inverse analysis. A bending experiment is used for the inverse analysis and the validation of the measurements. The out-of-plane displacements during loading are measured using digital speckle pattern interferometry. PMID:22090286

  18. Rapid localization of carbon 14-labeled molecules in biological samples by ion mass microscopy

    International Nuclear Information System (INIS)

    We report here on the ability of secondary ion mass spectrometry (SIMS) to provide rapid imaging of the intracellular distribution of 14C-labeled molecules. The validity of this method, using mass discrimination of carbon 14 atoms, was assessed by imaging the distribution of two molecules of well-known metabolism, [14C]-thymidine and [14C]-uridine, incorporated by human fibroblasts in culture. As expected, 14C ion images showed the presence of [14C]-thymidine in the nucleus of dividing cells, whereas [14C]-uridine was present in the cytoplasm as well as the nucleus of all cells, with a large concentration in the nucleoli. The time required to obtain the distribution images with the SMI 300 microscope was less than 6 min, whereas microautoradiography, the classical method for mapping the tissue distribution of 14C-labeled molecules, usually requires exposure times of several months. Secondary ion mass spectrometry using in situ mass discrimination is proposed here as a very sensitive method which permits rapid imaging of the subcellular distribution of molecules labeled with carbon 14

  19. Polybrominated diphenyl ethers in water, sediment, soil, and biological samples from different industrial areas in Zhejiang, China

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Junxia; Lin, Zhenkun [Zhejiang Provincial Key Lab for Technology and Application of Model Organisms, Institute of Watershed Science and Environmental Ecology, Wenzhou Medical College, Wenzhou 325035 (China); Lin, Kuangfei [School of Resources and Environmental Engineering, East China University of Science and Technology/State Environmental Protection Key Laboratory of Environmental Risk Assessment and Control on Chemical Process, Shanghai 200237 (China); Wang, Chunyan [Zhejiang Provincial Key Lab for Technology and Application of Model Organisms, Institute of Watershed Science and Environmental Ecology, Wenzhou Medical College, Wenzhou 325035 (China); Zhang, Wei [School of Resources and Environmental Engineering, East China University of Science and Technology/State Environmental Protection Key Laboratory of Environmental Risk Assessment and Control on Chemical Process, Shanghai 200237 (China); Cui, Changyuan [Zhejiang Provincial Key Lab for Technology and Application of Model Organisms, Institute of Watershed Science and Environmental Ecology, Wenzhou Medical College, Wenzhou 325035 (China); Lin, Junda [Department of Biological Sciences, Florida Institute of Technology, Melbourne, FL 32901 (United States); Dong, Qiaoxiang, E-mail: dqxdong@163.com [Zhejiang Provincial Key Lab for Technology and Application of Model Organisms, Institute of Watershed Science and Environmental Ecology, Wenzhou Medical College, Wenzhou 325035 (China); Huang, Changjiang, E-mail: cjhuang5711@163.com [Zhejiang Provincial Key Lab for Technology and Application of Model Organisms, Institute of Watershed Science and Environmental Ecology, Wenzhou Medical College, Wenzhou 325035 (China)

    2011-12-15

    Highlights: Black-Right-Pointing-Pointer We examined PBDE concentrations in various matrices from different industrial areas. Black-Right-Pointing-Pointer Elevated PBDE levels were found in areas with low-voltage electrical manufactures. Black-Right-Pointing-Pointer Areas with e-waste recycling activities also had higher PBDE concentrations. Black-Right-Pointing-Pointer PBDE content and composition in water samples varied from one area to another. Black-Right-Pointing-Pointer PBDE composition in sediment/soil and biological samples was predominated by BDE-209. - Abstract: Polybrominated diphenyl ethers (PBDEs) have been used extensively in electrical and electronic products, but little is known about their distribution in the environment surrounding the manufacturing factories. This study reports PBDE contamination in various matrices from the location (Liushi, Zhejiang province) that produces more than 70% of the low-voltage electrical appliances in China. Additionally, PBDE contamination was compared with other industries such as the e-waste recycling business (Fengjiang) in the same region. Specifically, we measured seven PBDE congeners (BDEs - 47, 99, 100, 153, 154, 183, and 209) in water, sediment, soil, plant, and animal tissues from four different areas in this region. The present study revealed elevated PBDE concentrations in all matrices collected from Liushi and Fengjiang in comparison with highly industrialized areas without significant PBDE contamination sources. In water samples, there were large variations of PBDE content and composition across different areas. In sediment/soil and biological samples, BDE-209 was the predominant congener and this could be due to the abundant usage of deca-BDE mixtures in China. Our findings provide the very first data on PBDE contamination in the local environments surrounding the electronics industry, and also reveal widespread PBDE contamination in highly industrialized coastal regions of China.

  20. A bench-top K X-ray fluorescence system for quantitative measurement of gold nanoparticles for biological sample diagnostics

    Science.gov (United States)

    Ricketts, K.; Guazzoni, C.; Castoldi, A.; Royle, G.

    2016-04-01

    Gold nanoparticles can be targeted to biomarkers to give functional information on a range of tumour characteristics. X-ray fluorescence (XRF) techniques offer potential quantitative measurement of the distribution of such heavy metal nanoparticles. Biologists are developing 3D tissue engineered cellular models on the centimetre scale to optimise targeting techniques of nanoparticles to a range of tumour characteristics. Here we present a high energy bench-top K-X-ray fluorescence system designed for sensitivity to bulk measurement of gold nanoparticle concentration for intended use in such thick biological samples. Previous work has demonstrated use of a L-XRF system in measuring gold concentrations but being a low energy technique it is restricted to thin samples or superficial tumours. The presented system comprised a high purity germanium detector and filtered tungsten X-ray source, capable of quantitative measurement of gold nanoparticle concentration of thicker samples. The developed system achieved a measured detection limit of between 0.2 and 0.6 mgAu/ml, meeting specifications of biologists and being approximately one order of magnitude better than the detection limit of alternative K-XRF nanoparticle detection techniques. The scatter-corrected K-XRF signal of gold was linear with GNP concentrations down to the detection limit, thus demonstrating potential in GNP concentration quantification. The K-XRF system demonstrated between 5 and 9 times less sensitivity than a previous L-XRF bench-top system, due to a fundamental limitation of lower photoelectric interaction probabilities at higher K-edge energies. Importantly, the K-XRF technique is however less affected by overlying thickness, and so offers future potential in interrogating thick biological samples.

  1. Introduction of ice protective film for 3D microscale analysis of biological sample

    Energy Technology Data Exchange (ETDEWEB)

    Iwanami, T. [Institute of Industrial Science, University of Tokyo, Meguro-ku, Tokyo 153-8505 (Japan)], E-mail: iwanami@iis.u-tokyo.ac.jp; Kinoshita, K. [Institute of Industrial Science, University of Tokyo, Meguro-ku, Tokyo 153-8505 (Japan); Nojima, M. [Institute of Industrial Science, University of Tokyo, Meguro-ku, Tokyo 153-8505 (Japan); Research Institute for Science and Technology, Tokyo University of Science, Noda-shi, Chiba 278-8510 (Japan); Owari, M. [Institute of Industrial Science, University of Tokyo, Meguro-ku, Tokyo 153-8505 (Japan); Enviromental Science Center, University of Tokyo, Bunkyo-ku, Tokyo 113-0033 (Japan)

    2008-12-15

    It is urgently necessary for secondary ion mass spectrometry (SIMS) analysis to overcome influence on the compositional distribution of the sample in vacuum chamber. In this study, we investigated the handling of the ice protective film in techniques such as the gallium focused ion beam (Ga FIB) etching. Here we demonstrate the technique with frozen Hymenochirus boettgeri red blood cell. The red blood cells covered with an ice protective film were cross-sectioned by using Ga FIB, and the two-dimensional SIMS mapping over the cross-section was carried out. The distributions of Na and K were observed on the cross-section and surface of red blood cell with ice protective film. This result agrees qualitatively with physiological intracellular and extracellular concentrations of vital cells. The technique used for SIMS was proved to be a reliable method, preserving the cells in their living state.

  2. Determination of boron in biological samples for the needs of neutron capture therapy

    International Nuclear Information System (INIS)

    Monitoring the actual concentration of 10B in a patient's blood is a prerequisite for determining the start and length of patient irradiation. The Prompt Gamma Ray Analysis (PGRA) method enables this nuclide to be determined rapidly and reliably within the region of 1 to 100 ppm. In this method, the characteristic line at 478 keV from the nuclear reaction 10B+n → 7Li+α+γ during sample exposure to thermal neutrons is used to determine boron. The facility which has been built up for this purpose comprises, in particular, a large-volume semiconductor detector for recording gamma rays emerging from the radiative neutron capture on the target

  3. Development of an improved immunoassay for detection of sorLA in cells and biological samples

    DEFF Research Database (Denmark)

    Andersen, Olav Michael; Thakurta, Ishita Guha; West, Mark J.

    bead releases singlet oxygen which triggers a series of chemical reactions in the acceptor beads causing a sharp peak of light emission at 615 nm. A series of experiments were designed to optimize the assay by conjugation of the beads to various anti-sorLA antibodies, cross titrations of the antibodies......, spike and recovery experiments to check matrix interference, signal to noise ratio determined for the counts, and comparison of our novel immunoassay in terms of sensitivity with existing methods. Results: Our results show that as compared to traditional methods, AlphaLISA is a sensitive and rapid assay......, which can be automated suitably for determination of sorLA in large sample batches. It also shows high recovery and signal to noise ratio. Conclusions: The results support the development of an improved method for measuring sorLA quantitatively, which could further prove as an important tool in...

  4. Simulated radioactive decontamination of biological samples using a portable DNA extraction instrument for rapid DNA profiling.

    Science.gov (United States)

    Frégeau, Chantal J; Dalpé, Claude

    2016-02-01

    A portable DNA extraction instrument was evaluated for its ability to decontaminate blood and saliva samples deposited on different surfaces (metal, plastic and glass) contaminated with stable isotopes of cobalt (Co), cesium (Cs), and strontium (Sr) as equivalents to their radiogenic (60)Co, (137)Cs, and (90)Sr isotopes, respectively, that could be released during a nuclear weapon accident or a radiological dispersal device (RDD) detonation. Despite the very high contamination levels tested in this study, successful removal of greater than 99.996% of the Co, Cs, Sr contaminants was achieved based on inductively coupled plasma-mass spectrometry (ICP-MS) and neutron activation analyses carried out on all liquids (including DNA eluates) and solid waste produced during automated DNA extraction. The remaining amounts of Co, Cs and Sr in the DNA eluates, when converted to dose rates (corresponding to (60)Co, (137)Cs and (90)Sr), were determined to be below the recommended dose limits for the general public in most of the scenarios tested. The presence of Co, Cs and Sr contaminants in the cell lysates had no adverse impact on the binding of DNA onto the magnetic DNA IQ™ beads. DNA yields were similar to uncontaminated controls. The remaining Co, Cs and Sr in the DNA eluates did not interfere with real-time PCR DNA quantification. In addition, the quality of the AmpFlSTR(®) Identifiler(®) profiles derived in 26min using an accelerated protocol was very good and comparable to controls. This study emphasizes the use of an accelerated process involving a portable DNA extraction instrument to significantly reduce radioactive dose rates to allow contaminated samples to be processed safely in a forensic mobile laboratory to expedite the identification of individuals potentially involved in the dispersal of nuclear or other radioactive materials. PMID:26773226

  5. Optimization of a radiochemistry method for plutonium determination in biological samples

    International Nuclear Information System (INIS)

    Plutonium has been widely used for civilian an military activities. Nevertheless, the methods to control work exposition have not evolved in the same way, remaining as one of the major challengers for the radiological protection practice. Due to the low acceptable incorporation limit, the usual determination is based on indirect methods in urine samples. Our main objective was to optimize a technique used to monitor internal contamination of workers exposed to Plutonium isotopes. Different parameters were modified and their influence on the three steps of the method was evaluated. Those which gave the highest yield and feasibility were selected. The method involves: 1-) Sample concentration (coprecipitation); 2-) Plutonium purification; and 3-) Source preparation by electrodeposition. On the coprecipitation phase, changes on temperature and concentration of the carrier were evaluated. On the ion-exchange separation, changes on the type of the resin, elution solution for hydroxylamine (concentration and volume), length and column recycle were evaluated. Finally, on the electrodeposition phase, we modified the following: electrolytic solution, pH and time. Measures were made by liquid scintillation counting and alpha spectrometry (PIPS). We obtained the following yields: 88% for coprecipitation (at 60 C degree with 2 ml of CaHPO4), 71% for ion-exchange (resins AG 1x8 Cl- 100-200 mesh, hydroxylamine 0.1N in HCl 0.2N as eluent, column between 4.5 and 8 cm), and 93% for electrodeposition (H2SO4-NH4OH, 100 minutes and pH from 2 to 2.8). The expand uncertainty was 30% (NC 95%), the decision threshold (Lc) was 0.102 Bq/L and the minimum detectable activity was 0.218 Bq/L of urine. We obtained an optimized method to screen workers exposed to Plutonium. (author)

  6. Trace level determination of molybdenum in environmental and biological samples using surfactant-mediated liquid-liquid extraction

    International Nuclear Information System (INIS)

    A novel and sensitive spectrophotometric method for the determination of molybdenum at trace levels in environmental and biological samples is proposed. The method is based on the reaction of Mo (V) with thiocyanate (SCN-) and methyltrioctyl ammonium chloride (MTOAC) in acidic medium. The red colored complex of molybdenum is extracted with N-phenylbenzimidoyl thiourea (PBITU) in 1-pentanol for its determination by spectrophotometry. The sensitivity of the present method is higher than other conventional thiocyanate method, due to the use of MTOAC in liquid-liquid extraction. The value of molar absorptivity of the complex with respect to molybdenum is 7.6 x 104 L mol-1 cm-1 at 470 nm. The limit of detection of the metal is 5 ng mL-1. The system obeys Beer's law between 20 and 1000 ng mL-1 with slope, intercept and correlation coefficient values of 0.81, 2.5 x 10-3 and +0.999, respectively. Most of the metal ions tested did not interfere in the determination of molybdenum. The proposed method has been successfully applied for the determination of the molybdenum in environmental and biological samples

  7. Trace level determination of molybdenum in environmental and biological samples using surfactant-mediated liquid-liquid extraction

    Energy Technology Data Exchange (ETDEWEB)

    Shrivas, Kamlesh [Department of Chemistry, National Sun Yat-Sen University, Kaohsiung 804, Taiwan (China)], E-mail: shrikam@rediffmail.com; Agrawal, Kavita [Department of Chemistry, Raipur Institute of Technology, Mandir Hasaud, Chhatauna Raipur, CG 492101 (India); Harmukh, Neetu [Chhattisgarh State Minor Forest Produce, Co-operative Federation Ltd., Raipur, CG (India)

    2009-01-15

    A novel and sensitive spectrophotometric method for the determination of molybdenum at trace levels in environmental and biological samples is proposed. The method is based on the reaction of Mo (V) with thiocyanate (SCN{sup -}) and methyltrioctyl ammonium chloride (MTOAC) in acidic medium. The red colored complex of molybdenum is extracted with N-phenylbenzimidoyl thiourea (PBITU) in 1-pentanol for its determination by spectrophotometry. The sensitivity of the present method is higher than other conventional thiocyanate method, due to the use of MTOAC in liquid-liquid extraction. The value of molar absorptivity of the complex with respect to molybdenum is 7.6 x 10{sup 4} L mol{sup -1} cm{sup -1} at 470 nm. The limit of detection of the metal is 5 ng mL{sup -1}. The system obeys Beer's law between 20 and 1000 ng mL{sup -1} with slope, intercept and correlation coefficient values of 0.81, 2.5 x 10{sup -3} and +0.999, respectively. Most of the metal ions tested did not interfere in the determination of molybdenum. The proposed method has been successfully applied for the determination of the molybdenum in environmental and biological samples.

  8. DeepQuanTR: MALDI-MS-based label-free quantification of proteins in complex biological samples.

    Science.gov (United States)

    Fugmann, Tim; Neri, Dario; Roesli, Christoph

    2010-07-01

    The quantification of changes in protein abundance in complex biological specimens is essential for proteomic studies in basic and applied research. Here we report on the development and validation of the DeepQuanTR software for identification and quantification of differentially expressed proteins using LC-MALDI-MS. Following enzymatic digestion, HPLC peptide separation and normalization of MALDI-MS signal intensities to the ones of internal standards, the software extracts peptide features, adjusts differences in HPLC retention times and performs a relative quantification of features. The annotation of multiple peptides to the corresponding parent protein allows the definition of a Protein Quant Value, which is related to protein abundance and which allows inter-sample comparisons. The performance of DeepQuanTR was evaluated by analyzing 24 samples deriving from human serum spiked with different amounts of four proteins and eight complex samples of vascular proteins, derived from surgically resected human kidneys with cancer following ex vivo perfusion with a reactive ester biotin derivative. The identification and experimental validation of proteins, which were differentially regulated in cancerous lesions as compared with normal kidney, was used to demonstrate the power of DeepQuanTR. This software, which can easily be used with established proteomic methodologies, facilitates the relative quantification of proteins derived from a wide variety of different samples. PMID:20455210

  9. Determination of Physicals, Chemical, Biologicals and Radioactivity Parameters of Sediments and Water Samples of Seropan River of First Period

    International Nuclear Information System (INIS)

    Seropan river water quality as residential water resources can be controlled by physical, chemical, and biological parameters. The water quality with the parameters of temperature, suspended solid (SS), gross β radioactivity, hardwater, COD, BOD, Escherichia Coli have been experimentally conducted. The sediment and water samples have been taken at February and August 2006. Measurement result of Seropan river water quality showed that the temperature was 28°C, maximum SS was 48 mg/L, maximum pH was 6.8 maximum hardwater was 257.49 mg/L, maximum COD was 8 mg/L, maximum BOD was 4.9 mg/L, maximum bacteria E. coli > 2400 mpn/100 mL, maximum water gross β was 0.9071 Bq/L. All the parameters were lower than maximum permissible for water condition that decided by Governor of Yogyakarta Special Province No/214/Kpts/1991 and Public Health Minister of Republic of Indonesia Number 907/Menkes/SK/VlI/2002. Sediment sample can not be evaluated because it was not included yet in the river water quality natural radionuclides gamma transmitter identified in river water samples were Tl-208 and K-40. More element detected in sediment samples, they were, Tl-208, Ac-228, Ra-226, Pb-212, Pb-214, Bi-214, Ac-228, Ac-228 and of K-40. (author)

  10. On-line preconcentration and determination of mercury in biological and environmental samples by cold vapor-atomic absorption spectrometry

    International Nuclear Information System (INIS)

    An on-line procedure for the determination of traces of total mercury in environmental and biological samples is described. The present methodology combines cold vapor generation associated to atomic absorption spectrometry (CV-AAS) with preconcentration of the analyte on a minicolumn packed with activated carbon. The retained analyte was quantitatively eluted from the minicolumn with nitric acid. After that, volatile specie of mercury was generated by merging the acidified sample and sodium tetrahydroborate(III) in a continuous flow system. The gaseous analyte was subsequently introduced via a stream of Ar carrier into the atomizer device. Optimizations of both, preconcentration and mercury volatile specie generation variables were carried out using two level full factorial design (23) with 3 replicates of the central point. Considering a sample consumption of 25 mL, an enrichment factor of 13-fold was obtained. The detection limit (3σ) was 10 ng L-1 and the precision (relative standard deviation) was 3.1% (n = 10) at the 5 μg L-1 level. The calibration curve using the preconcentration system for mercury was linear with a correlation coefficient of 0.9995 at levels near the detection limit up to at least 1000 μg L-1. Satisfactory results were obtained for the analysis of mercury in tap water and hair samples

  11. Determination of long-lived radionuclides in biological samples collected at Mururoa by a scientific delegation headed by the IAEA

    International Nuclear Information System (INIS)

    An international intercomparison exercise was conducted by the IAEA in 1994 on the edible fractions of biological samples collected in Mururoa. This article presents the results of additional measurements made on the inedible parts of marine samples, i.e., the gonads, viscera and livers of fish (groupers) and the hepatopancreas or viscera of mollusks (giant clams and turbos). The spread of data as a function of sampling locations has been investigated, while the concentration factors for several long-lived radionuclides have been determined and discussed. Plutonium-239/240 concentration data for giant clam flesh and hepatopancreas appear to be very close (approximately 0.6 Bq/kg wet weight), whereas 60Co concentrations are 100 times less in flesh (3 Bq/kg wet weight) than in hepatopancreas. As regards groupers, 239/240Pu and 60Co concentrations in flesh are very low and close to the detection limit. These concentration values are 100 to 500 times lower than those recorded in livers. As for turbos, plutonium and 60Co concentrations in viscera are 5 to 10 times higher than in soft parts. Based on these data, it becomes possible to determine which fractions of marine samples should be analyzed first in order to detect minute traces of 60Co, 137Cs and plutonium in Polynesia. (author)

  12. Perfluorooctanesulfonate and related fluorochemicals in biological samples from the north coast of Colombia

    Energy Technology Data Exchange (ETDEWEB)

    Olivero-Verbel, Jesus [Environmental and Computational Chemistry Group, Department of Chemistry, University of Cartagena, A.A. 6541 Cartagena (Colombia)]. E-mail: jesusolivero@yahoo.com; Tao, Lin [Wadsworth Center, New York State Department of Health and Department of Environmental Health Sciences, State University of New York at Albany, Empire State Plaza, PO Box 509, Albany, NY 12201-0509 (United States); Johnson-Restrepo, Boris [Environmental and Computational Chemistry Group, Department of Chemistry, University of Cartagena, A.A. 6541 Cartagena (Colombia); Wadsworth Center, New York State Department of Health and Department of Environmental Health Sciences, State University of New York at Albany, Empire State Plaza, PO Box 509, Albany, NY 12201-0509 (United States); Guette-Fernandez, Jorge [Environmental and Computational Chemistry Group, Department of Chemistry, University of Cartagena, A.A. 6541 Cartagena (Colombia); Baldiris-Avila, Rosa [Environmental and Computational Chemistry Group, Department of Chemistry, University of Cartagena, A.A. 6541 Cartagena (Colombia); O' byrne-Hoyos, Indira [Environmental and Computational Chemistry Group, Department of Chemistry, University of Cartagena, A.A. 6541 Cartagena (Colombia); Kannan, Kurunthachalam [Wadsworth Center, New York State Department of Health and Department of Environmental Health Sciences, State University of New York at Albany, Empire State Plaza, PO Box 509, Albany, NY 12201-0509 (United States)

    2006-07-15

    Perfluorinated compounds are widespread pollutants of toxicological importance that have been detected in environmental matrices. However, little is known on their distribution in South America. In this study, distribution of perfluorooctanesulfonate (PFOS), perfluorooctanoic acid (PFOA), perfluorohexanesulfonate (PFHxS), and perfluorooctanesulfonamide (PFOSA) was determined in the bile of mullet, Mugil incilis, and in tissues of pelicans (Pelecanus occidentalis) collected from North Colombia. Analysis was performed by HPLC mass spectrometry after ion-pair extraction. PFOS was found in all bile samples and PFOA and PFHxS were detected at lower frequency. Average concentrations of PFOS, PFOA, and PFHxS in bile of fish from Cartagena Bay, an industrialized site, and Totumo marsh, a reference site, were 3673, 370, 489 and 713, 47.4, 1.27 ng/mL, respectively. PFOS concentrations in pelican organs decreased in the order of spleen > liver > lung > kidney > brain > heart > muscle. These results suggest, for the first time, that perfluorinated compounds are also found in wildlife from Latin American countries. - Perfluorooctanesulfonate and related perfluorinated compounds have been found in a tropical ecosystem of South America.

  13. Perfluorooctanesulfonate and related fluorochemicals in biological samples from the north coast of Colombia

    International Nuclear Information System (INIS)

    Perfluorinated compounds are widespread pollutants of toxicological importance that have been detected in environmental matrices. However, little is known on their distribution in South America. In this study, distribution of perfluorooctanesulfonate (PFOS), perfluorooctanoic acid (PFOA), perfluorohexanesulfonate (PFHxS), and perfluorooctanesulfonamide (PFOSA) was determined in the bile of mullet, Mugil incilis, and in tissues of pelicans (Pelecanus occidentalis) collected from North Colombia. Analysis was performed by HPLC mass spectrometry after ion-pair extraction. PFOS was found in all bile samples and PFOA and PFHxS were detected at lower frequency. Average concentrations of PFOS, PFOA, and PFHxS in bile of fish from Cartagena Bay, an industrialized site, and Totumo marsh, a reference site, were 3673, 370, 489 and 713, 47.4, 1.27 ng/mL, respectively. PFOS concentrations in pelican organs decreased in the order of spleen > liver > lung > kidney > brain > heart > muscle. These results suggest, for the first time, that perfluorinated compounds are also found in wildlife from Latin American countries. - Perfluorooctanesulfonate and related perfluorinated compounds have been found in a tropical ecosystem of South America

  14. Radioreceptor assay for analysis of fentanyl and its analogs in biological samples

    International Nuclear Information System (INIS)

    The assay is based on the competition of these drugs with [3H] fentanyl for opioid receptors in membrane preparations of rat forebrain in vitro. The binding in stereospecific, reversible and saturable. Scatchard plots of saturation suggest the presence of high and low affinity binding sites. Morphine and hydromorphone complete with [3H]fentanyl for the opioid receptor, but other morphine-like compounds were relatively weak displacers of [3H]fentanyl. Many other commonly abused drugs do not compete with [3H]fentanyl for the opioid receptors. Urine samples from animals injected with fentanyl, (±)-cis-3-methylfentanyl, alpha-methylfentanyl, butyrylfentanyl and benzylfentanyl were analyzed by radioreceptor assay, radioimmunoassay, and gas chromatography/mass spectrometry. Urinary analysis of fentanyl showed a good correlation with these three methods; however, discrepancies were observed in the analysis of fentanyl analogs. This radioreceptor assay is well-suited as an initial assay for the detection of active analogs of fentanyl in urine with good correlation with other techniques in the analysis of fentanyl; however, there is substantial disagreement between techniques in the quantitation of fentanyl analogs. The implications of these discrepancies are discussed

  15. Radioreceptor assay for analysis of fentanyl and its analogs in biological samples

    Energy Technology Data Exchange (ETDEWEB)

    Alburges, M.E.

    1988-01-01

    The assay is based on the competition of these drugs with ({sup 3}H) fentanyl for opioid receptors in membrane preparations of rat forebrain in vitro. The binding in stereospecific, reversible and saturable. Scatchard plots of saturation suggest the presence of high and low affinity binding sites. Morphine and hydromorphone complete with ({sup 3}H)fentanyl for the opioid receptor, but other morphine-like compounds were relatively weak displacers of ({sup 3}H)fentanyl. Many other commonly abused drugs do not compete with ({sup 3}H)fentanyl for the opioid receptors. Urine samples from animals injected with fentanyl, ({plus minus})-cis-3-methylfentanyl, alpha-methylfentanyl, butyrylfentanyl and benzylfentanyl were analyzed by radioreceptor assay, radioimmunoassay, and gas chromatography/mass spectrometry. Urinary analysis of fentanyl showed a good correlation with these three methods; however, discrepancies were observed in the analysis of fentanyl analogs. This radioreceptor assay is well-suited as an initial assay for the detection of active analogs of fentanyl in urine with good correlation with other techniques in the analysis of fentanyl; however, there is substantial disagreement between techniques in the quantitation of fentanyl analogs. The implications of these discrepancies are discussed.

  16. Sensitive ergotamine determination in pharmaceuticals and biological samples using cloud point preconcentration and spectrofluorimetric detection.

    Science.gov (United States)

    Wang, Chien C; Fernández, Liliana P; Gómez, María Roxana

    2013-03-20

    A new cloud point extraction (CPE) method for ergotamine analysis using fluorimetric detection is described. Ergotamine from an aqueous solution was preconcentrated into a smaller surfactant-rich phase using nonionic surfactant polyoxyethylene(7.5)nonylphenylether (PONPE 7.5). Differently from the conventional CPE procedure in which the resulting surfactant-rich phase is diluted by a fluidificant before its analysis, in this method the fluorescence measurements were carried out directly onto the undiluted surfactant-rich phase. The high viscosity provided by the undiluted surfactant rich phase greatly improved the fluorescence emission of ergotamine, leading to a total enhancement factor of 1325. This spectral advantage plus the preconcentration factor achieved, contributed to the method sensitivity allowing the ergotamine determination at trace level concentration. Under optimal experimental conditions, a linear calibration curve was obtained from 3.81×10(-7) to 1.10μgmL(-1), with detection and quantification limits of 0.11 and 0.38pgmL(-1), respectively. The accuracy and versatility of the present methodology were proved by analyzing ergotamine in real samples of different natures such as pharmaceuticals, urine and saliva. PMID:23473254

  17. Signal and Image Processing of Optical Coherence Tomography at 1310 nm Wavelength for Non Biological Samples

    Directory of Open Access Journals (Sweden)

    Yogesh Rao

    2015-04-01

    Full Text Available OCT is a recently developed optical interferometric technique for non-invasive diagnostic medical imaging in vivo; the most sensitive optical imaging modality.OCT finds its application in ophthalmology, blood flow estimation and cancer diagnosis along with many non biomedical applications. The main advantage of OCT is its high resolution which is in µm range and depth of penetration in mm range. Unlike other techniques like X rays and CT scan, OCT does not comprise any x ray source and therefore no radiations are involved. This research work discusses the basics of spectral domain OCT (SD-OCT, experimental setup, data acquisition and signal processing involved in OCT systems. Simulation of OCT involving modelling and signal processing, carried out on Lab VIEW platform has been discussed. Using the experimental setup, some of the non biomedical samples have been scanned. The signal processing and image processing of the scanned data was carried out in MATLAB and Lab VIEW, some of the results thus obtained have been discussed in the end.

  18. Lead and cadmium determinations by atomic absorption technique in biological samples: blood, placenta and umbilical cord

    International Nuclear Information System (INIS)

    In order to determine the possibility contamination of lead and cadmium in pregnant women living in the mining-smelting city of La Oroya in Peru, lead and cadmium concentrations were assessed in maternal blood (pre-birth), umbilical cord blood and placental tissue. Forty deliveries with normal evolution were evaluated between October 2002 and January 2003. Samples were analyzed by atomic absorption on a graphite furnace at the Peruvian Institute of Nuclear Energy (IPEN) laboratories. Results are summarized as follows: a) Mean lead concentrations in maternal blood (MB), umbilical cord blood (UCB) and placental tissue (PT) were 27.23 μg/dL, 18.48 μg/dL and 363.97 μg/100g, respectively; b) Mean cadmium concentrations in MB, UCB and PT were 8.82 μg/dL, 12,0 μg/dL and 104,44 μg/100g, respectively; c) The correlation coefficient between lead concentration in maternal blood and umbilical cord was 0.122; d). The correlation coefficient of cadmium concentration between MB and UCB was 0.223; e). The correlation coefficient of lead concentration between MB and PT was 0.189; f). The correlation coefficient of cadmium concentration between MB and PT was 0.633. Trans-placental transport of lead was 67.84% (27,23 μg/dL in MB vs. 18.48 μg/dL in UCB); whereas in the case of cadmium, the concentration in UC (12,00 μg/dL) was greater than in MB (8.82 μg/dL.). These results could indicate that the placenta acts as a barrier trapping lead and cadmium. This barrier is efficient for lead since the concentration in cord blood is inferior to maternal blood but it is less efficient for cadmium. (author)

  19. Surfactant-Assisted Nanodrop Spectrophotometer Determination of Iron(III) in a Single Drop of Food, Biological, and Environmental Samples

    Science.gov (United States)

    Sharma, A.; Tapadia, K.; Sahin, R.; Shrivas, K.

    2016-01-01

    A surfactant-assisted nanodrop spectrophotometric (NDS) method has been developed for the determination of the iron(III) content in single drops (1 μ L) of food, biological, and or environmental sample using disodium 1-nitroso-2-naphthol-3,6-sulfonate (Nitroso-R salt) as a complexing agent and Tween-80 as non-ionic surfactant at pH 4.0. This method is based on the formation of a complex between the Fe(III) present in a sample and the Nitroso-R-salt in the presence of a surfactant to form a green-colored Fe(III)-Nitroso-R salt complex, which can be measured using a NDS method at a λ max = 710 nm. This system was found to obey Beer's law at concentrations in the range of 50-5000 μ g/L with slope, intercept and correlation coefficient values of 0.683, 0.102, and 0.986, respectively. The molar absorptivity of the complex in terms of the Fe(III) content was determined to be 4.86 × 10 5 L· mol -1 · cm -1 . The detection limit and %RSD values of the method were found to be 17 × 10-3 mg/L and ±1.3706%, respectively. This newly developed method was successfully applied to the determination of the Fe(III) content in single drops of food, biological, and environmental samples, and the results were compared with those obtained by atomic absorption spectrometry.

  20. Analysis of Turbulence Datasets using a Database Cluster: Requirements, Design, and Sample Applications

    Science.gov (United States)

    Meneveau, Charles

    2007-11-01

    The massive datasets now generated by Direct Numerical Simulations (DNS) of turbulent flows create serious new challenges. During a simulation, DNS provides only a few time steps at any instant, owing to storage limitations within the computational cluster. Therefore, traditional numerical experiments done during the simulation examine each time slice only a few times before discarding it. Conversely, if a few large datasets from high-resolution simulations are stored, they are practically inaccessible to most in the turbulence research community, who lack the cyber resources to handle the massive amounts of data. Even those who can compute at that scale must run simulations again forward in time in order to answer new questions about the dynamics, duplicating computational effort. The result is that most turbulence datasets are vastly underutilized and not available as they should be for creative experimentation. In this presentation, we discuss the desired features and requirements of a turbulence database that will enable its widest access to the research community. The guiding principle of large databases is ``move the program to the data'' (Szalay et al. ``Designing and mining multi-terabyte Astronomy archives: the Sloan Digital Sky Survey,'' in ACM SIGMOD, 2000). However, in the case of turbulence research, the questions and analysis techniques are highly specific to the client and vary widely from one client to another. This poses particularly hard challenges in the design of database analysis tools. We propose a minimal set of such tools that are of general utility across various applications. And, we describe a new approach based on a Web services interface that allows a client to access the data in a user-friendly fashion while allowing maximum flexibility to execute desired analysis tasks. Sample applications will be discussed. This work is performed by the interdisciplinary ITR group, consisting of the author and Yi Li(1), Eric Perlman(2), Minping Wan(1

  1. Determination of arsenenic compounds in environmental and biological samples with LAMMA and HPLC-ICP-MS

    International Nuclear Information System (INIS)

    Different arsonium salts and alkyl- or aryl arsine sulfides were analyzed with a Laser-Microprobe-Mass-Analyzer (LAMMA-500). The positive-ion spectra of the arsonium salts showed clear signals for the (CH3)3AsR+ fragment. In the positive-ion spectra of alkyl- or arylarsine sulfides these arsenic compounds the molecular ions R3AsS+ were never observed, but in most of the spectra the protonated parent compounds R3AsSH2+ were present. The negative-ion spectra showed mainly fragments S-n (n = 1, 2, 3, 4) and AsSn (n = 1, 2, 3). Chlorella vulgaris Beijerinck var. vulgaris with a concentration of 13,000 mg As/kg dry mass were analyzed with the LAMMA-500 to identify arsenic compounds. Surprisingly, arsenic could not be detected by the LAMMA technique at these high arsenic concentrations. Electron microscopy of Chlorella cells reveals, that particles adhered at the surface of the cells. Scanning transmission electron microscopy showed a high correlation between the arsenic concentration and the iron concentration in these particles. Algae may protect themselves from high arsenic concentrations, by precipitating FeAsO4 at the cell surface. Different Chlorella sp. were grown to investigate the arsenic tolerance of Chlorella strains. Chlorella Boehm and Chlorella Kessleri grew better in arsenic-containing than in arsenic-free media. The growth of Chlorella 108 was depressed in high-arsenic media. After harvesting, the algal biomass was extracted and arsenic compounds determined in the extracts with HPLC-ICP-MS. Approximately 98 % of the total arsenic were present as arsenic acid. A method for the simultaneous identification and quantification of arsenocholine, arsenous acid, dimethylarsinic acid, arsenobetaine, methylarsonic acid, and arsenic acid at concentrations below 1 μg/L was developed. The developed HPLC-MPN-ICP-MS system allows the determination of arsenic compounds in urine sample at concentrations of 0.5 μg As/L with a relative standard deviation of 20 %. (author)

  2. New Approach to Purging Monitoring Wells: Lower Flow Rates Reduce Required Purging Volumes and Sample Turbidity

    Science.gov (United States)

    It is generally accepted that monitoring wells must be purged to access formation water to obtain “representative” ground water quality samples. Historically anywhere from 3 to 5 well casing volumes have been removed prior to sample collection to evacuate the standing well water...

  3. Measurement of X-ray mass attenuation coefficients in biological and geological samples in the energy range of 7–12 keV

    International Nuclear Information System (INIS)

    Information about X-ray mass attenuation coefficients in different materials is necessary for accurate X-ray fluorescent analysis. The X-ray mass attenuation coefficients for energy of 7–12 keV were measured in biological (Mussel and Oyster tissues, blood, hair, liver, and Cabbage leaves) and geological (Baikal sludge, soil, and Alaskite granite) samples. The measurements were carried out at the EXAFS Station of Siberian Synchrotron Radiation Center (VEPP-3). Obtained experimental mass attenuation coefficients were compared with theoretical values calculated for some samples. - Highlights: • The X-ray attenuation coefficients were measured in biological and geological samples. • The difference between the attenuation coefficients in biological samples reached 47%. • The liver sample had the smallest attenuation coefficients. • The theoretical values for liver sample differ from the experimental ones by 2%

  4. Enhanced Biological Phosphorus Removal from Dairy Manure to Meet Nitrogen:Phosphorus Crop Nutrient Requirements

    OpenAIRE

    Yanosek, Kristina Anne

    2002-01-01

    Over the last two decades, livestock operations have become highly concentrated due to growing trends towards larger, more confined facilities and a decrease in cropland on smaller farms. This has led to greater amounts of excess manure nutrients on farms, increasing the potential for nutrient pollution of water bodies from runoff. The purpose of this study was to determine if enhanced biological phosphorus removal (EBPR) is a viable alternative for managing excess manure nutrients on dairy...

  5. Historical precedence and technical requirements of biological weapons use : a threat assessment.

    Energy Technology Data Exchange (ETDEWEB)

    Estes, Daniel P.; Vogel, Kathleen Margaret; Gaudioso, Jennifer Marie; Hickok, Lauren T.; Jung, Danielle F.; Barnett, Natalie Beth; Frerichs, Rebecca L.; Salerno, Reynolds Mathewson

    2004-05-01

    The threat from biological weapons is assessed through both a comparative historical analysis of the patterns of biological weapons use and an assessment of the technological hurdles to proliferation and use that must be overcome. The history of biological weapons is studied to learn how agents have been acquired and what types of states and substate actors have used agents. Substate actors have generally been more willing than states to use pathogens and toxins and they have focused on those agents that are more readily available. There has been an increasing trend of bioterrorism incidents over the past century, but states and substate actors have struggled with one or more of the necessary technological steps. These steps include acquisition of a suitable agent, production of an appropriate quantity and form, and effective deployment. The technological hurdles associated with the steps present a real barrier to producing a high consequence event. However, the ever increasing technological sophistication of society continually lowers the barriers, resulting in a low but increasing probability of a high consequence bioterrorism event.

  6. Rapid Isolation and Determination of Flavones in Biological Samples Using Zinc Complexation Coupled with High-Performance Liquid Chromatography.

    Science.gov (United States)

    Sun, Chenghe; Wang, Hecheng; Wang, Yingping; Xiao, Shengyuan

    2016-01-01

    Chlorophyll-type contaminants are commonly encountered in the isolation and determination of flavones of plant aerial plant parts. Heme is also a difficult background substance in whole blood analysis. Both chlorophyll and heme are porphyrin type compounds. In this study, a rapid method for isolating flavones with 5-hydroxyl or ortho-hydroxyl groups from biological samples was developed based on the different solubilities of porphyrin-metal and flavone-metal complexes. It is important that other background substances, e.g., proteins and lipids, are also removed from flavones without an additional processing. The recoveries of scutellarin, baicalin, baicalein, wogonoside and wogonin, which are the primary constituents of Scutellaria baicalensis (skullcaps) were 99.65% ± 1.02%, 98.98% ± 0.73%, 99.65% ± 0.03%, 97.59% ± 0.09% and 95.19% ± 0.47%, respectively. As a sample pretreatment procedure, this method was coupled to high-performance liquid chromatography (HPLC) with good separation, sensitivity and linearity and was applied to determine the flavone content in different aerial parts of S. baicalensis and in dried blood spot samples. PMID:27537870

  7. Rapid Isolation and Determination of Flavones in Biological Samples Using Zinc Complexation Coupled with High-Performance Liquid Chromatography

    Directory of Open Access Journals (Sweden)

    Chenghe Sun

    2016-08-01

    Full Text Available Chlorophyll-type contaminants are commonly encountered in the isolation and determination of flavones of plant aerial plant parts. Heme is also a difficult background substance in whole blood analysis. Both chlorophyll and heme are porphyrin type compounds. In this study, a rapid method for isolating flavones with 5-hydroxyl or ortho-hydroxyl groups from biological samples was developed based on the different solubilities of porphyrin-metal and flavone-metal complexes. It is important that other background substances, e.g., proteins and lipids, are also removed from flavones without an additional processing. The recoveries of scutellarin, baicalin, baicalein, wogonoside and wogonin, which are the primary constituents of Scutellaria baicalensis (skullcaps were 99.65% ± 1.02%, 98.98% ± 0.73%, 99.65% ± 0.03%, 97.59% ± 0.09% and 95.19% ± 0.47%, respectively. As a sample pretreatment procedure, this method was coupled to high-performance liquid chromatography (HPLC with good separation, sensitivity and linearity and was applied to determine the flavone content in different aerial parts of S. baicalensis and in dried blood spot samples.

  8. Assessment of selenium and mercury in biological samples of normal and night blindness children of age groups (3-7) and (8-12) years.

    Science.gov (United States)

    Afridi, Hassan Imran; Kazi, Tasneem Gul; Talpur, Farah Naz; Kazi, Atif; Arain, Sadaf Sadia; Arain, Salma Aslam; Brahman, Kapil Dev; Panhwar, Abdul Haleem; Khan, Naeemullah; Arain, Mariam Shazadi; Ali, Jamshed

    2015-03-01

    The causes of night blindness in children are multifactorial and particular consideration has been given to childhood nutritional deficiency, which is the most common problem found in underdeveloped countries. Such deficiency can result in physiological and pathological processes that in turn influence biological sample composition. This study was designed to compare the levels of selenium (Se) and mercury (Hg) in scalp hair, blood, and urine of night blindness children age ranged (3-7) and (8-12) years of both genders, comparing them to sex- and age-matched controls. A microwave-assisted wet acid digestion procedure was developed as a sample pretreatment for the determination of Se and Hg in biological samples of night blindness children. The proposed method was validated by using conventional wet digestion and certified reference samples of hair, blood, and urine. The Se and Hg in biological samples were measured by electrothermal atomic absorption spectrometry and cold vapor atomic absorption spectrometry, prior to microwave acid digestion, respectively. The concentration of Se was decreased in scalp hair and blood samples of male and female night blindness children while Hg was higher in all biological samples as compared to referent subjects. The Se concentration was inversely associated with the risk of night blindness in both genders. These results add to an increasing body of evidence that Se is a protecting element for night blindness. These data present guidance to clinicians and other professional investigating deficiency of essential micronutrients in biological samples (scalp hair and blood) of night blindness children. PMID:25655123

  9. Microwave assisted digestion of organoarsenic compounds for the determination of total arsenic in aqueous, biological, and sediment samples using FI-HG-ETAAS (P8)

    International Nuclear Information System (INIS)

    Full text: A microwave assisted wet digestion method for organo-arsenic compounds and subsequent determination of total arsenic in aqueous, biological and sediment samples by means of flow injection hydride generation electrothermal atomic absorption spectrometry is described. Sodium persulfate, sodium fluoride and nitric acid serve as digestion reagents, which allow a quantitative transformation of organo-arsenic compounds to hydride forming species in a commercial microwave sample preparation system. Arsenic recovery from aqueous testing solutions of dimethylarsinic acid, phenylarsonic acid and tetraphenylarsonium chloride at initial concentrations of 100 μg l-1 and 10 μg l-1 is complete, even in the presence of an excess of organic carbon or fatty acids. Arsenic recovery from aqueous arsenobetaine solutions with the same initial concentrations is also complete if high pressure vessels and a higher concentration of fluoride ions are used, whereas the addition of organic carbon leads to a decrease in arsenic recovery of about 2 % to 5 %. In all cases, residual carbon contents are close to the limit of detection for the applied analytical method (15 mg l-1). Results of arsenic analysis in reference standard materials revealed a significant dependence on the material's nature. Sediment samples and plant materials show recoveries for arsenic around 100 % after a single-step digestion in medium pressure (30 bar) tetrafluorometoxil liners. Seafood usually require either the use of high pressure vessels (75 bar) or a second digestion step if medium pressure vessels are used. (author)

  10. Minimum and Maximum Times Required to Obtain Representative Suspended Sediment Samples

    Science.gov (United States)

    Gitto, A.; Venditti, J. G.; Kostaschuk, R.; Church, M. A.

    2014-12-01

    Bottle sampling is a convenient method of obtaining suspended sediment measurements for the development of sediment budgets. While these methods are generally considered to be reliable, recent analysis of depth-integrated sampling has identified considerable uncertainty in measurements of grain-size concentration between grain-size classes of multiple samples. Point-integrated bottle sampling is assumed to represent the mean concentration of suspended sediment but the uncertainty surrounding this method is not well understood. Here we examine at-a-point variability in velocity, suspended sediment concentration, grain-size distribution, and grain-size moments to determine if traditional point-integrated methods provide a representative sample of suspended sediment. We present continuous hour-long observations of suspended sediment from the sand-bedded portion of the Fraser River at Mission, British Columbia, Canada, using a LISST laser-diffraction instrument. Spectral analysis suggests that there are no statistically significant peak in energy density, suggesting the absence of periodic fluctuations in flow and suspended sediment. However, a slope break in the spectra at 0.003 Hz corresponds to a period of 5.5 minutes. This coincides with the threshold between large-scale turbulent eddies that scale with channel width/mean velocity and hydraulic phenomena related to channel dynamics. This suggests that suspended sediment samples taken over a period longer than 5.5 minutes incorporate variability that is larger scale than turbulent phenomena in this channel. Examination of 5.5-minute periods of our time series indicate that ~20% of the time a stable mean value of volumetric concentration is reached within 30 seconds, a typical bottle sample duration. In ~12% of measurements a stable mean was not reached over the 5.5 minute sample duration. The remaining measurements achieve a stable mean in an even distribution over the intervening interval.

  11. Solvent-dependent turn-on probe for dual monitoring of Ag+ and Zn2+ in living biological samples

    International Nuclear Information System (INIS)

    Highlights: • A solvent-dependent probe was presented for dual monitoring of Ag+ and Zn2+. • The probe exhibited special selectivity and sensitivity at physiological range. • The mechanism was investigated both experimentally and computationally. • The probe was highly suitable for mapping Ag+ and Zn2+ in biological samples. - Abstract: A novel, solvent-dependent “off–on” probe with benzoylthiourea moiety as the functional receptor and fluorescein as the fluorophore was designed for monitoring of Ag+ in EtOH–H2O (2:8, v/v) solution and Zn2+ in CH3CN–H2O (2:8, v/v) solution at physiological range with sufficient selectivity and sensitivity. The Ag+ promoted desulfurization of thiosemicarbazide functionality in formation of the 1,3,4-oxadiazole and the coordination of Zn2+ to the O atom and N atom of the spoirolactam moiety and the S atom of the benzoylthiourea moiety were investigated to be the power that promoted the fluorescent enhancement. This probe was tested highly suitable for mapping Ag+ and Zn2+ in living human osteosarcoma MG-63 cells and microbial cell–EPS–mineral aggregates, thus, providing a wonderful candidate for tracking Ag+ and Zn2+ in biological organisms and processes

  12. The Constitutive Content of the Crime of Refusal or Evasion from Collecting Biological Samples in the Romanian Criminal Law

    Directory of Open Access Journals (Sweden)

    Minodora-Ioana BĂLAN-RUSU

    2015-03-01

    Full Text Available In the paper we have examined the constitutive content of the offense of refusal or evasion from collecting biological samples, with elements of similarity and differences between the current and the old law. The comparative examination is useful as it allows the identification and application of a more favorable criminal law, in the case where such an offense is committed under the influence of the old law and it is to be finally judged after the entry into force of the new law. This work continues and completes the monograph “Offenses against traffic safety on public roads in the Romanian criminal law”, published in 2014 (Universul Juridic. The work can be useful to judicial bodies responsible for law enforcement, and academics from law schools (teachers, students and master students. The innovations consist in examining the constitutive content and the elements of similarity and differences between the two regulations.

  13. Development of a radiochemical neutron activation analysis procedure for determination of rhenium in biological and environmental samples at ultratrace level

    International Nuclear Information System (INIS)

    Radiochemical neutron activation procedures using liquid-liquid extraction with tetraphenylarsonium chloride in chloroform from 1M HCl and solid extraction with ALIQUAT 336 incorporated in a polyacrylonitrile binding matrix from 0.1M HCl were developed for accurate determination of rhenium in biological and environmental samples at the sub-ng x g-1 level. Concentrations of Re in the range of 0.1 to 2.4 ng x g-1 were determined in several botanical reference materials (RM), while in a RM of road dust a value of ∼ 10 ng x g-1 was found. Significantly elevated values of Re, up to 90 ng x g-1 were found in seaweed (brown algae). Results for Re in the brown algae Fucus vesiculosus in which elevated 99Tc values had previously been determined suggested possible competition between Re and Tc in the accumulation process. (author)

  14. Copper and zinc level in biological samples from healthy subjects of vegetarian food habit in reference to community environment

    Energy Technology Data Exchange (ETDEWEB)

    Bhattacharya, R.D.; Patel, T.S.; Pandya, C.B.

    1985-04-01

    Many epidemiologists have found a correlation between copper and zinc in the community environment and diseases, such as myocardial and vascular pathologies, and diabetes. The purpose of this study was to investigate the total daily intake of these two metals in cooked food, drinking water and air and their respective levels in blood and urine. A chronobiological methodology has been adopted to establish the reference values of these two metals in biological samples. It has been observed that the daily intake of copper is within the recommended value, whereas its urinary excretion is high. The daily intake of zinc is below the recommended value and its urinary excretion is also high. Both the metals showed a temporal oscillation pattern in blood and urine. A possible chronic zinc deficiency has been anticipated in this particular ethnic group of vegetarian food habit.

  15. Development of ultrasound-assisted extraction for mercury speciation studies in biological samples using HPLC-ID-ICP-MS

    International Nuclear Information System (INIS)

    An efficient and simple ultrasound-assisted extraction method has been developed to determine inorganic and methyl mercury in biological samples by high performance liquid chromatography coupled with isotope dilution inductively coupled plasma mass spectrometry (HPLC-ID- ICP-MS). The operational parameters of ultrasound-assisted extraction, such as extractant composition, sonication time and extraction temperature, were optimized. The interconversion between CH3198Hg+ and 198Hg2+ during the operation was monitored by isotopic mercury-198 tracer technique. The efficiency of the extraction of inorganic and methyl mercury in biological samples was evaluated by total mercury determination using inductively coupled plasmas mass spectrometry. The best optimal extraction parameters are 30 minutes at 50 degree C for sonication using 0.05% (m/v) cysteine and 0.05% (v/v) 2-mercaptoethanol as extractant. The recovery of inorganic and methyl mercury was validated by four certified reference materials, including IAEA MA-B-3/TM tuna fish, NIST 1566a bovine liver, IAEA 350 fish mussel and GBW 07601 human hair. As for speciation study, a key point is that the original elemental speciation should be kept during the processing. Therefore, the above four certified reference materials spiked with CH3198Hg+ and 198Hg2+ were used to investigate the interconversion of methyl mercury into inorganic mercury or vice versa during the extraction. The CH3198Hg+ and 198Hg2+ were determined by high performance liquid chromatography coupled with inductively coupled plasma mass spectrometry. The data show that the interconversion between CH3198Hg+ and 198Hg2+ during the operation is negligible. This extraction method is more simple and convenient than the common used ones and is more suitable for simultaneous determination of inorganic and methyl mercury by HPLC-ICP-MS technique.

  16. Probabilistic Requirements (Partial) Verification Methods Best Practices Improvement. Variables Acceptance Sampling Calculators: Derivations and Verification of Plans. Volume 1

    Science.gov (United States)

    Johnson, Kenneth L.; White, K, Preston, Jr.

    2012-01-01

    The NASA Engineering and Safety Center was requested to improve on the Best Practices document produced for the NESC assessment, Verification of Probabilistic Requirements for the Constellation Program, by giving a recommended procedure for using acceptance sampling by variables techniques. This recommended procedure would be used as an alternative to the potentially resource-intensive acceptance sampling by attributes method given in the document. This document contains the outcome of the assessment.

  17. Determination of As, Cd, Cu, Hg and Pb in biological samples by modern electrothermal atomic absorption spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Sardans, Jordi, E-mail: j.sardans@creaf.uab.ca [Ecophysiological and Global Change Unit CSIC-CREAF, Edifici C, Universitat Autonoma de Barcelona, Bellaterra 08193, Barcelona (Spain); Montes, Fernando [Departamento de Ciencias Analiticas, Facultad de Ciencias, Universidad Nacional de Educacion a Distancia (UNED), C/ Senda del Rey 9. 28040 Madrid (Spain); Penuelas, Josep [Ecophysiological and Global Change Unit CSIC-CREAF, Edifici C, Universitat Autonoma de Barcelona, Bellaterra 08193, Barcelona (Spain)

    2010-02-15

    of this technique that reaches figures of merit equivalent to Inductively coupled plasma mass spectrometry (ICP-MS). Herein is presented an overview of recent advances and applications of (ETAAS) for the determination of As, Cd, Cu, Hg and Pb in biological samples drawn from studies over the last decade.

  18. NG09 And CTBT On-Site Inspection Noble Gas Sampling and Analysis Requirements

    Science.gov (United States)

    Carrigan, Charles R.; Tanaka, Junichi

    2010-05-01

    A provision of the Comprehensive Test Ban Treaty (CTBT) allows on-site inspections (OSIs) of suspect nuclear sites to determine if the occurrence of a detected event is nuclear in origin. For an underground nuclear explosion (UNE), the potential success of an OSI depends significantly on the containment scenario of the alleged event as well as the application of air and soil-gas radionuclide sampling techniques in a manner that takes into account both the suspect site geology and the gas transport physics. UNE scenarios may be broadly divided into categories involving the level of containment. The simplest to detect is a UNE that vents a significant portion of its radionuclide inventory and is readily detectable at distance by the International Monitoring System (IMS). The most well contained subsurface events will only be detectable during an OSI. In such cases, 37 Ar and radioactive xenon cavity gases may reach the surface through either "micro-seepage" or the barometric pumping process and only the careful siting of sampling locations, timing of sampling and application of the most site-appropriate atmospheric and soil-gas capturing methods will result in a confirmatory signal. The OSI noble gas field tests NG09 was recently held in Stupava, Slovakia to consider, in addition to other field sampling and analysis techniques, drilling and subsurface noble gas extraction methods that might be applied during an OSI. One of the experiments focused on challenges to soil-gas sampling near the soil-atmosphere interface. During withdrawal of soil gas from shallow, subsurface sample points, atmospheric dilution of the sample and the potential for introduction of unwanted atmospheric gases were considered. Tests were designed to evaluate surface infiltration and the ability of inflatable well-packers to seal out atmospheric gases during sample acquisition. We discuss these tests along with some model-based predictions regarding infiltration under different near

  19. Evaluation of non-invasive biological samples to monitor Staphylococcus aureus colonization in great apes and lemurs.

    Directory of Open Access Journals (Sweden)

    Frieder Schaumburg

    Full Text Available INTRODUCTION: Reintroduction of endangered animals as part of conservational programs bears the risk of importing human pathogens from the sanctuary to the natural habitat. One bacterial pathogen that serves as a model organism to analyze this transmission is Staphylococcus aureus as it can colonize and infect both humans and animals. The aim of this study was to evaluate the utility of various biological samples to monitor S. aureus colonization in great apes and lemurs. METHODS: Mucosal swabs from wild lemurs (n=25, Kirindy, Madagascar, feces, oral and genital swabs from captive chimpanzees (n=58, Ngamba and Entebbe, Uganda and fruit wadges and feces from wild chimpanzees (n=21, Taï National Parc, Côte d'Ivoire were screened for S. aureus. Antimicrobial resistance and selected virulence factors were tested for each isolate. Sequence based genotyping (spa typing, multilocus sequence typing was applied to assess the population structure of S. aureus. RESULTS: Oro-pharyngeal carriage of S. aureus was high in lemurs (72%, n=18 and captive chimpanzees (69.2%, n=27 and 100%, n=6, respectively. Wild chimpanzees shed S. aureus through feces (43.8, n=7 and fruit wadges (54.5, n=12. Analysis of multiple sampling revealed that two samples are sufficient to detect those animals which shed S. aureus through feces or fruit wadges. Genotyping showed that captive animals are more frequently colonized with human-associated S. aureus lineages. CONCLUSION: Oro-pharyngeal swabs are useful to screen for S. aureus colonization in apes and lemurs before reintroduction. Duplicates of stool and fruit wadges reliably detect S. aureus shedding in wild chimpanzees. We propose to apply these sampling strategies in future reintroduction programs to screen for S. aureus colonization. They may also be useful to monitor S. aureus in wild populations.

  20. 40 CFR 258.53 - Ground-water sampling and analysis requirements.

    Science.gov (United States)

    2010-07-01

    ... control. (b) The ground-water monitoring program must include sampling and analytical methods that are...-water protection standard, the test shall be done at a Type I error level no less than 0.01 for each... ground-water monitoring data, the specific type of control chart and its associated parameter...

  1. Is Mars Sample Return Required Prior to Sending Humans to Mars?

    Science.gov (United States)

    Carr, Michael; Abell, Paul; Allwood, Abigail; Baker, John; Barnes, Jeff; Bass, Deborah; Beaty, David; Boston, Penny; Brinkerhoff, Will; Budney, Charles; Charles, John; Delory, Greg; Desai, Prasun; DesMarais, David; Drake, Brett; Hamilton, Victoria; Head, Jim; Heldmann, Jen; Hoffman, Steve; Kass, David; Lim, Darlene; Meyer, Michael; Munk, Michelle; Murchie, Scott; Rivkin, Andy

    2012-01-01

    Prior to potentially sending humans to the surface of Mars, it is fundamentally important to return samples from Mars. Analysis in Earth's extensive scientific laboratories would significantly reduce the risk of human Mars exploration and would also support the science and engineering decisions relating to the Mars human flight architecture. The importance of measurements of any returned Mars samples range from critical to desirable, and in all cases these samples will would enhance our understanding of the Martian environment before potentially sending humans to that alien locale. For example, Mars sample return (MSR) could yield information that would enable human exploration related to 1) enabling forward and back planetary protection, 2) characterizing properties of Martian materials relevant for in situ resource utilization (ISRU), 3) assessing any toxicity of Martian materials with respect to human health and performance, and 4) identifying information related to engineering surface hazards such as the corrosive effect of the Martian environment. In addition, MSR would be engineering 'proof of concept' for a potential round trip human mission to the planet, and a potential model for international Mars exploration.

  2. Is routine karyotyping required in prenatal samples with a molecular or metabolic referral?

    Directory of Open Access Journals (Sweden)

    Kooper Angelique JA

    2012-01-01

    Full Text Available Abstract As a routine, karyotyping of invasive prenatal samples is performed as an adjunct to referrals for DNA mutation detection and metabolic testing. We performed a retrospective study on 500 samples to assess the diagnostic value of this procedure. These samples included 454 (90.8% chorionic villus (CV and 46 (9.2% amniocenteses specimens. For CV samples karyotyping was based on analyses of both short-term culture (STC and long-term culture (LTC cells. Overall, 19 (3.8% abnormal karyotypes were denoted: four with a common aneuploidy (trisomy 21, 18 and 13, two with a sex chromosomal aneuploidy (Klinefelter syndrome, one with a sex chromosome mosaicism and twelve with various autosome mosaicisms. In four cases a second invasive test was performed because of an abnormal finding in the STC. Taken together, we conclude that STC and LTC karyotyping has resulted in a diagnostic yield of 19 (3.8% abnormal cases, including 12 cases (2.4% with an uncertain significance. From a diagnostic point of view, it is desirable to limit uncertain test results as secondary test findings. Therefore, we recommend a more targeted assay, such as e.g. QF-PCR, as a replacement of the STC and to provide parents the autonomy to choose between karyotyping and QF-PCR.

  3. Poly(A)-binding proteins are required for diverse biological processes in metazoans.

    Science.gov (United States)

    Smith, Richard W P; Blee, Tajekesa K P; Gray, Nicola K

    2014-08-01

    PABPs [poly(A)-binding proteins] bind to the poly(A) tail of eukaryotic mRNAs and are conserved in species ranging from yeast to human. The prototypical cytoplasmic member, PABP1, is a multifunctional RNA-binding protein with roles in global and mRNA-specific translation and stability, consistent with a function as a central regulator of mRNA fate in the cytoplasm. More limited insight into the molecular functions of other family members is available. However, the consequences of disrupting PABP function in whole organisms is less clear, particularly in vertebrates, and even more so in mammals. In the present review, we discuss current and emerging knowledge with respect to the functions of PABP family members in whole animal studies which, although incomplete, already underlines their biological importance and highlights the need for further intensive research in this area. PMID:25110030

  4. Voltammetric method for sensitive determination of herbicide picloram in environmental and biological samples using boron-doped diamond film electrode

    International Nuclear Information System (INIS)

    The voltammetric behavior and determination of picloram, a member of a pyridine herbicide family, was for the first time investigated on a boron doped diamond film electrode using cyclic and differential pulse voltammetry. The influence of supporting electrolyte and scan rate on the current response of picloram was examined to select the optimum experimental conditions. It was found that picloram provided one well-shaped oxidation peak at very positive potential (+1.5 V vs. Ag/AgCl electrode) in strong acidic medium. At optimized differential pulse voltammetric parameters, the current response of picloram was proportionally linear in the concentration range from 0.5 to 48.07 μmol L−1 and the low limit of detection of 70 nmol L−1 as well as good repeatability (relative standard deviation of 2.6% at 10 μmol L−1 for n = 11) were obtained on unmodified boron-doped diamond film electrode. The proposed method was successfully applied in analysis of environmental (tap and natural water) and biological (human urine) samples spiked with picloram with good accuracy (relative standard deviations less than 5% for all samples, n = 5). By this way, the boron-doped diamond could introduce a green (environmentally acceptable) alternative to mercury electrodes for the monitoring of herbicides

  5. Application of slurry nebulization to trace elemental analysis of some biological samples by inductively coupled plasma mass spectrometry

    International Nuclear Information System (INIS)

    The application of slurry nebulization/inductively coupled plasma mass spectrometry (ICP-MS) to trace elemental analysis of biological samples has been investigated. Three standard samples of the National Institute of Standards and Technology (NIST) were dispersed in 1% aqueous Triton X-100 solution by grinding with a planetary micronizing mill. The resulting slurries were nebulized into an ICP without any additional treatments. The 1% (m/v) slurry of the NIST bovine liver showed no significant influence on cone blockage and signal suppression/enhancement. Detection limit, precision and accuracy were discussed for the determination of 24 elements of interest in bovine liver, rice flour and pine needles. Detection limits ranged from 0.0001 μg g-1 for U to 0.52 μg g-1 for Zn at the effective integrating time of 10 s. For high mass elements, low blank values were obtained, yielding excellent limits (-1). Acceptable accuracy and precision were obtained for most of the elements in the NIST bovine liver and rice flour, even for the volatile elements, such as As, Se and Br. However, relatively poor accuracy was obtained for the analysis of pine needles. (orig.)

  6. Determination of the samples required of water-sensitive paper in experiments related spray technology

    Directory of Open Access Journals (Sweden)

    Alexandre Ballarotti Nascimento

    2013-12-01

    Full Text Available The raise in the numbers of samples increase the confidence level of the results. However little is know about the minimum number of water-sensitive papers cards that must be used in studies of spray technology. Thus, the aim of this paper was to determine the minimum number of water-sensitive papers cards used in spray experiments, based on the variables: percentage of coverage, number of drops per cm2 and volume median diameter (VMD. It were realized an experiment in factorial design 2x2 with five replicates, each containing 36 cards. With the objective to have variability among the treatments, the factors involveed were nozzles (TR110-01 and ULD120-015 and operational pressures (138 and 276 kPa, because the size of droplets is modified even by the nozzle as by operational pressures. As estimative precision, the mean errors assumed was 20%, 15% and 10%, that generated numbers of samples as: 7, 12 and 26, respectively, for percentage of coverage; 5, 8 and 16, respectively, for number of drops per cm2; and 1.2 and 4 respectively, for volume median diameter (VMD. Analysis of variance complemented by Tukey test at 5% probability were realized for the average of 36 cards and the average of the minimum number of papers (samples determined. Comparing statically the averages obtained in the experiment for each variable for n=36 samples and n= samples determined at 20% error, noted that the results are identical in both situations, demonstrating that spray rates and different droplet sizes influenced directly in the parameters evaluated. It is possible to conclude that the minimum number of water-sensitive papers cards per repetition (1 m2 for this experiment is 7,5, and 1 for percentage of coverage, number of droplet per cm2 and volume median diameter (VMD, respectively.

  7. 40 CFR 141.24 - Organic chemicals, sampling and analytical requirements.

    Science.gov (United States)

    2010-07-01

    ... approved by the Director of the Federal Register in accordance with 5 U.S.C. 552(a) and 1 CFR part 51...) Editorial Note: For Federal Register citations affecting § 141.24, see the List of CFR Sections Affected... analytical requirements. 141.24 Section 141.24 Protection of Environment ENVIRONMENTAL PROTECTION...

  8. Mars Sample Return: The Next Step Required to Revolutionize Knowledge of Martian Geological and Climatological History

    Science.gov (United States)

    Mittlefehldt, D. W.

    2012-01-01

    The capability of scientific instrumentation flown on planetary orbiters and landers has made great advances since the signature Viking mission of the seventies. At some point, however, the science return from orbital remote sensing, and even in situ measurements, becomes incremental, rather than revolutionary. This is primarily caused by the low spatial resolution of such measurements, even for landed instrumentation, the incomplete mineralogical record derived from such measurements, the inability to do the detailed textural, mineralogical and compositional characterization needed to demonstrate equilibrium or reaction paths, and the lack of chronological characterization. For the foreseeable future, flight instruments will suffer from this limitation. In order to make the next revolutionary breakthrough in understanding the early geological and climatological history of Mars, samples must be available for interrogation using the full panoply of laboratory-housed analytical instrumentation. Laboratory studies of samples allow for determination of parageneses of rocks through microscopic identification of mineral assemblages, evaluation of equilibrium through electron microbeam analyses of mineral compositions and structures, determination of formation temperatures through secondary ion or thermal ionization mass spectrometry (SIMS or TIMS) analyses of stable isotope compositions. Such details are poorly constrained by orbital data (e.g. phyllosilicate formation at Mawrth Vallis), and incompletely described by in situ measurements (e.g. genesis of Burns formation sediments at Meridiani Planum). Laboratory studies can determine formation, metamorphism and/or alteration ages of samples through SIMS or TIMS of radiogenic isotope systems; a capability well-beyond flight instrumentation. Ideally, sample return should be from a location first scouted by landers such that fairly mature hypotheses have been formulated that can be tested. However, samples from clastic

  9. Mercury in Environmental and Biological Samples Using Online Combustion with Sequential Atomic Absorption and Fluorescence Measurements: A Direct Comparison of Two Fundamental Techniques in Spectrometry

    Science.gov (United States)

    Cizdziel, James V.

    2011-01-01

    In this laboratory experiment, students quantitatively determine the concentration of an element (mercury) in an environmental or biological sample while comparing and contrasting the fundamental techniques of atomic absorption spectrometry (AAS) and atomic fluorescence spectrometry (AFS). A mercury analyzer based on sample combustion,…

  10. Design and development of a miniaturised total chemical analysis system for on-line lactate and glucose monitoring in biological samples

    NARCIS (Netherlands)

    Dempsey, Eithne; Diamond, Dermot; Smyth, Malcolm R.; Urban, Gerald; Jobst, Gerhard; Moser, Isabella; Verpoorte, Elisabeth M.J.; Manz, Andreas; Widmer, H. Michael; Rabenstein, Kai; Freaney, Rosemarie

    1997-01-01

    A miniaturised Total chemical Analysis System (μTAS) for glucose and lactate measurement in biological samples constructed based on an integrated microdialysis sampling and detection system. The complete system incorporates a microdialysis probe for intravascular monitoring in an ex vivo mini-shunt

  11. Chemical Data for Rock, Sediment, Biological, Precipitate, and Water Samples from Abandoned Copper Mines in Prince William Sound, Alaska

    Science.gov (United States)

    Koski, Randolph A.; Munk, LeeAnn

    2007-01-01

    Introduction In the early 20th century, approximately 6 million metric tons of copper ore were mined from numerous deposits located along the shorelines of fjords and islands in Prince William Sound, Alaska. At the Beatson, Ellamar, and Threeman mine sites (fig. 1), rocks containing Fe, Cu, Zn, and Pb sulfide minerals are exposed to chemical weathering in abandoned mine workings and remnant waste piles that extend into the littoral zone. Field investigations in 2003 and 2005 as well as analytical data for rock, sediment, precipitate, water, and biological samples reveal that the oxidation of sulfides at these sites is resulting in the generation of acid mine drainage and the transport of metals into the marine environment (Koski and others, 2008; Stillings and others, 2008). At the Ellamar and Threeman sites, plumes of acidic and metal-enriched water are flowing through beach gravels into the shallow offshore environment. Interstitial water samples collected from beach sediment at Ellamar have low pH levels (to ~3) and high concentrations of metals including iron, copper, zinc, cobalt, lead, and mercury. The abundant precipitation of the iron sulfate mineral jarosite in the Ellamar gravels also signifies a low-pH environment. At the Beatson mine site (the largest copper mine in the region) seeps containing iron-rich microbial precipitates drain into the intertidal zone below mine dumps (Foster and others, 2008). A stream flowing down to the shoreline from underground mine workings at Beatson has near-neutral pH, but elevated levels of zinc, copper, and lead (Stillings and others, 2008). Offshore sediment samples at Beatson are enriched in these metals. Preliminary chemical data for tissue from marine mussels collected near the Ellamar, Threeman, and Beatson sites reveal elevated levels of copper, zinc, and lead compared to tissue in mussels from other locations in Prince William Sound (Koski and others, 2008). Three papers presenting results of this ongoing

  12. Global requirements for DNA sample collections: results of a survey of 204 ethics committees in 40 countries.

    Science.gov (United States)

    Ricci, D S; Broderick, E D; Tchelet, A; Hong, F; Mayevsky, S; Mohr, D M; Schaffer, M E; Warner, A W; Hakkulinen, P; Snapir, A

    2011-04-01

    The Industry Pharmacogenomics Working Group has an interest in attaining a better understanding of global requirements for sample collections intended for pharmacogenetics research. To have adequately powered pharmacogenetics studies representative of the clinical trial population, it is important to collect DNA samples from a majority of consenting study participants under many institutional review board/ethics committee (IRB/EC) jurisdictions. A survey was distributed to gather information from local and central IRBs/ECs. The survey included questions related to the approval of pharmacogenetics studies, collection and banking of samples, and return of data to subjects. A total of 204 responses were received from global IRBs/ECs with pharmacogenetic experience. The data show that requirements for approval of pharmacogenetic research differ between IRBs/ECs within and between countries but not between regions of the United States. A better understanding of differing requirements should facilitate global sample collection of DNA for pharmacogenetics research and may provide the basis for harmonized regulations for collection of genetic samples in the future. PMID:21346753

  13. Stable isotope gas chromatography-tandem mass spectrometry determination of aminoethylcysteine ketimine decarboxylated dimer in biological samples.

    Science.gov (United States)

    Tsikas, Dimitrios; Evans, Christopher E; Denton, Travis T; Mitschke, Anja; Gutzki, Frank-Mathias; Pinto, John T; Khomenko, Tetyana; Szabo, Sandor; Cooper, Arthur J L

    2012-11-01

    Aminoethylcysteine ketimine decarboxylated dimer (AECK-DD; systematic name: 1,2-3,4-5,6-7,8-octahydro-1,8a-diaza-4,6-dithiafluoren-9(8aH)-one) is a previously described metabolite of cysteamine that has been reported to be present in mammalian brain, urine, plasma, and cells in culture and vegetables and to possess potent antioxidative properties. Here, we describe a stable isotope gas chromatography-tandem mass spectrometry (GC-MS/MS) method for specific and sensitive determination of AECK-DD in biological samples. (13)C(2)-labeled AECK-DD was synthesized and used as the internal standard. Derivatization was carried out by N-pentafluorobenzylation with pentafluorobenzyl bromide in acetonitrile. Quantification was performed by selected reaction monitoring of the mass transitions m/z 328 to 268 for AECK-DD and m/z 330 to 270 for [(13)C(2)]AECK-DD in the electron capture negative ion chemical ionization mode. The procedure was systematically validated for human plasma and urine samples. AECK-DD was not detectable in human plasma above approximately 4nM but was present in urine samples of healthy humans at a maximal concentration of 46nM. AECK-DD was detectable in rat brain at very low levels of approximately 8pmol/g wet weight. Higher levels of AECK-DD were detected in mouse brain (∼1nmol/g wet weight). Among nine dietary vegetables evaluated, only shallots were found to contain trace amounts of AECK-DD (∼6.8pmol/g fresh tissue). PMID:22858756

  14. Analysis of proteins in biological samples by capillary sieving electrophoresis with postcolumn derivatization/laser-induced fluorescence detection.

    Science.gov (United States)

    Kaneta, Takashi; Ogura, Takehito; Imasaka, Totaro

    2011-04-01

    Previously, we have demonstrated postcolumn derivatization of proteins separated by capillary sieving electrophoresis (CSE), in which naphthalene-2,3-dicarbaldehyde was employed as a fluorogenic labeling reagent. Standard proteins separated by CSE were reacted with naphthalene-2,3-dicarbaldehyde in the presence of 2-mercaptoethanol (2-ME) which plays a role of a reducing agent in the derivatization reaction. To improve the sensitivity, we attempted the use of ethanethiol instead of 2-ME. Ethanethiol showed 1.4- to 4.5-fold lower limits of detection for proteins than 2-ME. Furthermore, we found that 8-aminopyrene-1,3,6-trisulfonate (APTS) is a good marker for relative electrophoretic mobilities of proteins in CSE. Since APTS is a fluorescent and trivalent anion, it generates strong fluorescence and migrates faster than any of the proteins. Therefore, we employed APTS as a marker to obtain the relative electrophoretic mobilities of proteins. The present method was applied to the analyses of proteins in biological samples. Human Ewing's family tumor cell line 'RDES' was used as a sample. The cultured cells were lysed with a buffer containing Tris-HCl, NaCl, sodium dodecyl sulfate, and 2-ME. After denaturation, the lysate was directly introduced into the capillary. Several peaks, which would correspond to proteins with molecular mass ranging from 10 to 93 kDa, were found in the cell lysate. In addition, we measured a milk sample by the CSE with postcolumn derivatization. The electropherogram showed five major peaks which corresponded to α-lactalbumin, β-lactoglobulin, κ-casein, bovine serum albumin, and mixture of α- and β-casein. PMID:21449073

  15. The IAEA worldwide intercomparison exercises (1990-1997). Determination of trace elements in marine sediments and biological samples

    International Nuclear Information System (INIS)

    Four major worldwide intercomparison exercises for the determination of trace elements in various environmental matrices were completed by the IAEA Marine Environment Laboratory since 1990: SD-M-2/TM, deep sea marine sediment; IAEA-350, tuna fish homogenate; IAEA-356, contaminated coastal sediment and IAEA-140, sea plant (Fucus sp.). These intercomparison exercises aim at enabling individual laboratories to monitor their performance. The results of these exercises allowed us to make an overall evaluation of the quality of data provided for environmental assessment and to identify the trends of analytical performance in the determination of trace elements over the years. The number of participants in each exercise varied between 68 and 130, and permits statistical evaluation of the performance for a number of elements. For each intercomparison exercise, the performance of the participant laboratories was assessed by comparing reported results with established reference values calculating 'Z-scores'. The results show that for each sample matrix, the values reported by some laboratories were far from satisfactory in the earlier exercises, in particular for Cd, Cr and Pb. Nevertheless, over time, a general improvement of performance can clearly be seen for all elements. Moreover, there was a noticeable increase in the number of laboratories with good performance in the two most recent exercises, observed both for biological and for sediment matrices. However, the determination of trace elements such as Cd, Cr, Pb and Hg in low level environmental samples still remains a major challenge to the analysts. For this reason and in order to assess the current performance of laboratories for low environmental levels of contaminants, the future intercomparison exercises will concentrate on low level sediment and fish samples

  16. Sample requirements and design of an inter-laboratory trial for radiocarbon laboratories

    OpenAIRE

    Bryant, C.; Carmi, [No Value; Cook, G; Gulliksen, S; Harkness, D; Heinemeier, J.; McGee, E.; Naysmith, P.; G. Possnert; van der Plicht, H; VAN STRYDONCK, M; Carmi, Israel

    2000-01-01

    An on-going inter-comparison programme which is focused on assessing and establishing consensus protocols to be applied in the identification, selection and sub-sampling of materials for subsequent C-14 analysis is described. The outcome of the programme will provide a detailed quantification of the uncertainties associated with C-14 measurements including the issues of accuracy and precision. Such projects have become recognised as a fundamental aspect of continuing laboratory quality assura...

  17. Pre-Mission Input Requirements to Enable Successful Sample Collection by A Remote Field/EVA Team

    Science.gov (United States)

    Cohen, B. A.; Lim, D. S. S.; Young, K. E.; Brunner, A.; Elphic, R. E.; Horne, A.; Kerrigan, M. C.; Osinski, G. R.; Skok, J. R.; Squyres, S. W.; Saint-Jacques, D.; Heldmann, J. L.

    2016-01-01

    The FINESSE (Field Investigations to Enable Solar System Science and Exploration) team, part of the Solar System Exploration Virtual Institute (SSERVI), is a field-based research program aimed at generating strategic knowledge in preparation for human and robotic exploration of the Moon, near-Earth asteroids, Phobos and Deimos, and beyond. In contract to other technology-driven NASA analog studies, The FINESSE WCIS activity is science-focused and, moreover, is sampling-focused with the explicit intent to return the best samples for geochronology studies in the laboratory. We used the FINESSE field excursion to the West Clearwater Lake Impact structure (WCIS) as an opportunity to test factors related to sampling decisions. We examined the in situ sample characterization and real-time decision-making process of the astronauts, with a guiding hypothesis that pre-mission training that included detailed background information on the analytical fate of a sample would better enable future astronauts to select samples that would best meet science requirements. We conducted three tests of this hypothesis over several days in the field. Our investigation was designed to document processes, tools and procedures for crew sampling of planetary targets. This was not meant to be a blind, controlled test of crew efficacy, but rather an effort to explicitly recognize the relevant variables that enter into sampling protocol and to be able to develop recommendations for crew and backroom training in future endeavors.

  18. Ultra-trace determination of arsenic species in environmental waters, food and biological samples using a modified aluminum oxide nanoparticle sorbent and AAS detection after multivariate optimization

    International Nuclear Information System (INIS)

    We describe a simple and efficient method for solid phase extraction and speciation of trace quantities of arsenic. It is based on the use of functionalized aluminum oxide nanoparticles and does not require any oxidation or reduction steps. The experimental parameters affecting extraction and quantitation were optimized using fractional factorial design methods. Adsorbed arsenic was eluted from the sorbent with 1 M hydrochloric acid and determined by graphite furnace atomic absorption spectrometry. Preconcentration factors up to 750 were achieved depending on the sample volume. Studies on potential interferences by various anions and cations showed the method to be highly selective. Under optimum conditions, the calibration plots are linear in the 5.0 to 280 ng L−1 and 8.0 to 260 ng L−1 concentration ranges for As(III) and total arsenic, respectively. The detection limits (calculated for S/N ratios of 3) are 1.81 and 1.97 ng L−1 for As(III) and total arsenic, respectively. The method was successfully applied to the determination and speciation of arsenic in (spiked) environmental, food and biological samples and gave good recoveries. The method was validated using a certified geological reference material. (author)

  19. Processes and procedures for a worldwide biological samples distribution; product assurance and logistic activities to support the mice drawer system tissue sharing event

    Science.gov (United States)

    Benassai, Mario; Cotronei, Vittorio

    The Mice Drawer System (MDS) is a scientific payload developed by the Italian Space Agency (ASI), it hosted 6 mice on the International Space Station (ISS) and re-entered on ground on November 28, 2009 with the STS 129 at KSC. Linked to the MDS experiment, a Tissue Sharing Program (TSP), was developed in order to make available to 16 Payload Investigators (PI) (located in USA, Canada, EU -Italy, Belgium and Germany -and Japan) the biological samples coming from the mice. ALTEC SpA (a PPP owned by ASI, TAS-I and local institutions) was responsible to support the logistics aspects of the MDS samples for the first MDS mission, in the frame of Italian Space Agency (ASI) OSMA program (OSteoporosis and Muscle Atrophy). The TSP resulted in a complex scenario, as ASI, progressively, extended the original OSMA Team also to researchers from other ASI programs and from other Agencies (ESA, NASA, JAXA). The science coordination was performed by the University of Genova (UNIGE). ALTEC has managed all the logistic process with the support of a specialized freight forwarder agent during the whole shipping operation phases. ALTEC formalized all the steps from the handover of samples by the dissection Team to the packaging and shipping process in a dedicated procedure. ALTEC approached all the work in a structured way, performing: A study of the aspects connected to international shipments of biological samples. A coopera-tive work with UNIGE/ASI /PIs to identify all the needs of the various researchers and their compatibility. A complete revision and integration of shipment requirements (addresses, tem-peratures, samples, materials and so on). A complete definition of the final shipment scenario in terms of boxes, content, refrigerant and requirements. A formal approach to identification and selection of the most suited and specialized Freight Forwarder. A clear identification of all the processes from sample dissection by PI Team, sample processing, freezing, tube preparation

  20. Double-salting out assisted liquid-liquid extraction (SALLE) HPLC method for estimation of temozolomide from biological samples.

    Science.gov (United States)

    Jain, Darshana; Athawale, Rajani; Bajaj, Amrita; Shrikhande, Shruti

    2014-11-01

    The role of temozolomide (TMZ) in treatment of high grade gliomas, melanomas and other malignancies is being defined by the current clinical developmental trials. Temozolomide belongs to the group of alkylating agents and is prescribed to patients suffering from most aggressive forms of brain tumors. The estimation techniques for temozolomide from the extracted plasma or biological samples includes high-performance liquid chromatography with UV detection (HPLC-UV), micellar electrokinetic capillary chromatography (MKEC) and liquid chromatography coupled to mass spectroscopy (LC-MS). These methods suffer from disadvantages like low resolution, low sensitivity, low recovery or cost involvement. An analytical method possessing capacity to estimate low quantities of TMZ in plasma samples with high extraction efficiency (%) and high resolution with cost effectiveness needs to be developed. Cost effective, robust and low plasma component interfering HPLC method using salting out liquid-liquid extraction (SALLE) technique was developed and validated for estimation of drug from plasma samples. The extraction efficiency (%) with conventional LLE technique with methanol, ethyl acetate, dichloromethane and acetonitrile was found to be 5.99±2.45, 45.39±4.56, 46.04±1.14 and 46.23±3.67 respectively. Extraction efficiency (%) improved with SALLE where sodium chloride was used as an electrolyte and was found to be 6.80±5.56, 52.01±3.13, 62.69±2.11 and 69.20±1.18 with methanol, ethyl acetate, dichloromethane and acetonitrile as organic solvent. Upon utilization of two salts for extraction (double salting liquid-liquid extraction) the extraction efficiency (%) was further improved and was twice of LLE. It was found that double salting liquid-liquid extraction technique yielded extraction efficiency (%) of 11.71±5.66, 55.62±3.44, 77.28±2.89 and 87.75±0.89. Hence a method based on double SALLE was developed for quantification of TMZ demonstrating linearity in the range of

  1. Requirements for representative sampling for fluvial fish assemblages – literary review

    Directory of Open Access Journals (Sweden)

    Potyó, I.

    2012-12-01

    Full Text Available Fish are good indicators of long-term changes of fluvial ecosystems therefore, assessment of fish assemblages is frequently used in evaluation of the ecological status of surface waters, especially since the implementation of the EU Water Framework Directive. Long-term changes of fish fauna and old-time abundance of fish populations in the Danube can be documented by historical data of fisheries. Direct detection of long-term changes of fish populations in large rivers is a difficult task due to large-scale temporal and spatial variability of fish distribution. The present study provides a review of river fish sampling methods, with special attention to approaches based on electrofishing. Our goal is to develop a standard monitoring method in large rivers to get more reliable and consistent data for description of long-term changes of fish populations.

  2. An improved lectin-based method for the detection of mucin-type O-glycans in biological samples.

    Science.gov (United States)

    Lee, Cheng-Siang; Muthusamy, Arivalagan; Abdul-Rahman, Puteri Shafinaz; Bhavanandan, Veer P; Hashim, Onn Haji

    2013-06-21

    Mucins and mucin-type glycoproteins, collectively referred to as mucin-type O-glycans, are implicated in many important biological functions and pathological conditions, including malignancy. Presently, there is no reliable method to measure the total mucin-type O-glycans of a sample, which may contain one or more of these macromolecules of unknown structures. We report the development of an improved microassay that is based on the binding of lectins to the unique and constant GalNAc-Ser/Thr structural feature of mucin-type O-glycans. Since the sugar-amino acid linkage in the mucin-type O-glycans is invariably cryptic, we first chemically removed the heterogeneous peripheral and core saccharides of model glycoconjugates before examining for their interactions using an enzyme-linked lectin assay (ELLA). Desialylation of the model glycoconjugates led to maximal binding of the lectins but additional treatments such as Smith degradation did not result in increased binding. Of the lectins tested for their ability to probe the desialylated O-glycans, jacalin showed the highest sensitivity followed by champedak galactose binding (CGB) lectin and Vicia villosa agglutinin. Further improvement in the sensitivity of ELLA was achieved by using microtiter plates that were pre-coated with the CGB lectin, which increased the specificity of the assay to mucin-type O-glycans. Finally, the applicability of the developed sandwich ELLA to crude samples was demonstrated by estimating trace quantities of the mucin-type O-glycans in the human serum. PMID:23665615

  3. High temperature liquid chromatography-inductively coupled plasma mass spectrometry for the determination of arsenosugars in biological samples.

    Science.gov (United States)

    Terol, Amanda; Ardini, Francisco; Grotti, Marco; Todolí, José Luis

    2012-11-01

    The potential of high temperature liquid chromatography (HTLC) with detection by inductively coupled plasma mass spectrometry (ICP-MS) for the determination of arsenosugars in marine organisms was examined for the first time. The retention behavior of four naturally occurring dimethylarsinoylribosides was studied on a graphite column using plain water as mobile phase. An aqueous solution of pH 8, ionic strength 13.8mM and containing 2% (v/v) of methanol, along with a column temperature of 120°C and a liquid flow rate of 1.0 mL/min, were selected as the optimal conditions, as they allowed the separation of the four arsenosugars in less than 18 min, without any interferences due to other common arsenic species (arsenite, arsenate, dimethylarsinate, methylarsonate and arsenobetaine). The run time could be further decreased to 12 min by working at 1.5 mL/min, although with a 3-4 times loss of sensitivity. The procedural limits of detection were 0.03-0.04 μg As/g dry mass, and the precision of the procedure ranged from 4% for arsenosugar glycerol to 18% for arsenosugar sulfate (RSD%, n=5). The developed method was applied to a number of representative biological samples, such as algae and crustaceans, providing results consistent with previous studies. In the red algae samples, the most of extracted arsenic was as arsenosugars (81-97%), mainly arsenosugar phosphate (56-94%). On the other hand, lower concentrations of these compounds were found in the crustacean, accounting for about 15% of the extracted arsenic. PMID:22995196

  4. Chemical derivatization for enhancing sensitivity during LC/ESI-MS/MS quantification of steroids in biological samples: a review.

    Science.gov (United States)

    Higashi, Tatsuya; Ogawa, Shoujiro

    2016-09-01

    Sensitive and specific methods for the detection, characterization and quantification of endogenous steroids in body fluids or tissues are necessary for the diagnosis, pathological analysis and treatment of many diseases. Recently, liquid chromatography/electrospray ionization-tandem mass spectrometry (LC/ESI-MS/MS) has been widely used for these purposes due to its specificity and versatility. However, the ESI efficiency and fragmentation behavior of some steroids are poor, which lead to a low sensitivity. Chemical derivatization is one of the most effective methods to improve the detection characteristics of steroids in ESI-MS/MS. Based on this background, this article reviews the recent advances in chemical derivatization for the trace quantification of steroids in biological samples by LC/ESI-MS/MS. The derivatization in ESI-MS/MS is based on tagging a proton-affinitive or permanently charged moiety on the target steroid. Introduction/formation of a fragmentable moiety suitable for the selected reaction monitoring by the derivatization also enhances the sensitivity. The stable isotope-coded derivatization procedures for the steroid analysis are also described. PMID:26454158

  5. Programmable selected ion monitoring for quantitative analysis of biological samples with a GC-MS-computer system

    International Nuclear Information System (INIS)

    Maximum sensitivity of a mass spectrometer used as a detector for a gas chromatograph can be achieved by monitoring only the ion current at a single mass per charge. However, greater confidence in the analytical results can be achieved by monitoring at least 2 ions from a compound of interest. Since a biological sample may contain several different compounds of interest, it may be desirable to monitor as many as 8 to 12 different ions so that all components may be quantified. However, the greater the number of ions monitored, the poorer the signal to noise ratio available for monitoring any given ion current. A compromise between obtaining maximum sensitivity and confidence in analytical results can be achieved by monitoring only 2 or 3 ions during any given time interval of the gas chromatogram when the corresponding compounds are expected to emerge from the GC. This procedure is illustrated with a computer (PDP-12A)-controlled dodecapole gas chromatograph-mass spectrometer with analyses of prostaglandins and biogenic amines

  6. Stability Study and Kinetic Monitoring of Cefquinome Sulfate Using Cyclodextrin-Based Ion-Selective Electrode: Application to Biological Samples.

    Science.gov (United States)

    Yehia, Ali M; Arafa, Reham M; Abbas, Samah S; Amer, Sawsan M

    2016-01-01

    Two novel cefquinome sulfate (CFQ)-selective electrodes were performed with dibutyl sebacate as a plasticizer using a polymeric matrix of polyvinyl chloride. Sensor 1 was prepared using sodium tetraphenylborate as a cation exchanger without incorporation of ionophore, whereas 2-hydroxy propyl β-cyclodextrin was used as ionophore in sensor 2. A stable, reliable, and linear response was obtained in concentration ranges 3.2 × 10(-5) to 1 × 10(-2) mol/L and 1 × 10(-5) to 1 × 10(-2) mol/L for sensors 1 and 2, respectively. Both sensors could be sufficiently applied for quantitative determination of CFQ in the presence of degradation products either in bulk powder or in pharmaceutical formulations. Sensor 2 provided better selectivity and sensitivity, wider linearity range, and higher performance. Therefore it was used successfully for accurate determination of CFQ in biological fluids such as spiked plasma and milk samples. Furthermore, an online kinetic study was applied to the CFQ alkaline degradation process to estimate the reaction rate and half-life with feasible real-time monitoring. The developed sensors were found to be fast, accurate, sensitive, and precise compared with the manufacturer's reversed-phase chromatographic method. PMID:26822094

  7. FACE Analysis as a Fast and Reliable Methodology to Monitor the Sulfation and Total Amount of Chondroitin Sulfate in Biological Samples of Clinical Importance

    Directory of Open Access Journals (Sweden)

    Evgenia Karousou

    2014-06-01

    Full Text Available Glycosaminoglycans (GAGs due to their hydrophilic character and high anionic charge densities play important roles in various (pathophysiological processes. The identification and quantification of GAGs in biological samples and tissues could be useful prognostic and diagnostic tools in pathological conditions. Despite the noteworthy progress in the development of sensitive and accurate methodologies for the determination of GAGs, there is a significant lack in methodologies regarding sample preparation and reliable fast analysis methods enabling the simultaneous analysis of several biological samples. In this report, developed protocols for the isolation of GAGs in biological samples were applied to analyze various sulfated chondroitin sulfate- and hyaluronan-derived disaccharides using fluorophore-assisted carbohydrate electrophoresis (FACE. Applications to biologic samples of clinical importance include blood serum, lens capsule tissue and urine. The sample preparation protocol followed by FACE analysis allows quantification with an optimal linearity over the concentration range 1.0–220.0 µg/mL, affording a limit of quantitation of 50 ng of disaccharides. Validation of FACE results was performed by capillary electrophoresis and high performance liquid chromatography techniques.

  8. METHODS FOR DETERMINING AGITATOR MIXING REQUIREMENTS FOR A MIXING & SAMPLING FACILITY TO FEED WTP (WASTE TREATMENT PLANT)

    Energy Technology Data Exchange (ETDEWEB)

    GRIFFIN PW

    2009-08-27

    The following report is a summary of work conducted to evaluate the ability of existing correlative techniques and alternative methods to accurately estimate impeller speed and power requirements for mechanical mixers proposed for use in a mixing and sampling facility (MSF). The proposed facility would accept high level waste sludges from Hanford double-shell tanks and feed uniformly mixed high level waste to the Waste Treatment Plant. Numerous methods are evaluated and discussed, and resulting recommendations provided.

  9. [Critical Study of the last jurisprudence of the Supreme Court on requirements and guarantees regarding DNA sampling from suspects].

    Science.gov (United States)

    de Hoyos Sancho, Montserrat

    2012-01-01

    A critical study will be made of recent jurisprudence of Spanish Supreme Court in relation to the principal requirements that current legislation establishes for so-called "DNA testing", specially in connection with the rules on lawful evidence. In particular, the various hypotheses and circumstances that might concur in the collection of tissue samples from the suspect will be analyzed, as well as questions relating to the need, or otherwise, of legal assistance during such an act. PMID:23115827

  10. Effect of sample preparation techniques on the concentrations and distributions of elements in biological tissues using µSRXRF: a comparative study

    International Nuclear Information System (INIS)

    Routine tissue sample preparation using chemical fixatives is known to preserve the morphology of the tissue being studied. A competitive method, cryofixation followed by freeze drying, involves no chemical agents and maintains the biological function of the tissue. The possible effects of both sample preparation techniques in terms of the distribution of bio-metals (calcium (Ca), copper (Cu) zinc (Zn), and iron (Fe) specifically) in human skin tissue samples was investigated. Micro synchrotron radiation x-ray fluorescence (μSRXRF) was used to map bio-metal distribution in epidermal and dermal layers of human skin samples from various locations of the body that have been prepared using both techniques. For Ca, Cu and Zn, there were statistically significant differences between the epidermis and dermis using the freeze drying technique (p = 0.02, p < 0.01, and p < 0.01, respectively). Also using the formalin fixed, paraffin embedded technique the levels of Ca, Cu and Zn, were significantly different between the epidermis and dermis layers (p = 0.03, p < 0.01, and p < 0.01, respectively). However, the difference in levels of Fe between the epidermis and dermis was unclear and further analysis was required. The epidermis was further divided into two sub-layers, one mainly composed of the stratum corneum and the other deeper layer, the stratum basale. It was found that the difference between the distribution of Fe in the two epidermal layers using the freeze drying technique resulted in a statistically significant difference (p = 0.012). This same region also showed a difference in Fe using the formalin fixed, paraffin embedded technique (p < 0.01). The formalin fixed, paraffin embedded technique also showed a difference between the deeper epidermal layer and the dermis (p < 0.01). It can be concluded that studies involving Ca, Cu and Zn might show similar results using both sample preparation techniques, however studies involving Fe would need more

  11. Tripodal chelating ligand-based sensor for selective determination of Zn(II) in biological and environmental samples

    Energy Technology Data Exchange (ETDEWEB)

    Kumar Singh, Ashok; Mehtab, Sameena; Singh, Udai P.; Aggarwal, Vaibhave [Indian Institute of Technology-Roorkee, Department of Chemistry, Roorkee (India)

    2007-08-15

    Potassium hydrotris(N-tert-butyl-2-thioimidazolyl)borate [KTt{sup t-Bu}] and potassium hydrotris(3-tert-butyl-5-isopropyl-l-pyrazolyl)borate [KTp{sup t-Bu,i-Pr}] have been synthesized and evaluated as ionophores for preparation of a poly(vinyl chloride) (PVC) membrane sensor for Zn(II) ions. The effect of different plasticizers, viz. benzyl acetate (BA), dioctyl phthalate (DOP), dibutyl phthalate (DBP), tributyl phosphate (TBP), and o-nitrophenyl octyl ether (o-NPOE), and the anion excluders sodium tetraphenylborate (NaTPB), potassium tetrakis(p-chlorophenyl)borate (KTpClPB), and oleic acid (OA) were studied to improve the performance of the membrane sensor. The best performance was obtained from a sensor with a of [KTt{sup t-Bu}] membrane of composition (mg): [KTt{sup t-Bu}] (15), PVC (150), DBP (275), and NaTPB (4). This sensor had a Nernstian response (slope, 29.4 {+-} 0.2 mV decade of activity) for Zn{sup 2+} ions over a wide concentration range (1.4 x 10{sup -7} to 1.0 x 10{sup -1} mol L{sup -1}) with a limit of detection of 9.5 x 10{sup -8} mol L{sup -1}. It had a relatively fast response time (12 s) and could be used for 3 months without substantial change of the potential. The membrane sensor had very good selectivity for Zn{sup 2+} ions over a wide variety of other cations and could be used in a working pH range of 3.5-7.8. The sensor was also found to work satisfactorily in partially non-aqueous media and could be successfully used for estimation of zinc at trace levels in biological and environmental samples. (orig.)

  12. Tripodal chelating ligand-based sensor for selective determination of Zn(II) in biological and environmental samples.

    Science.gov (United States)

    Singh, Ashok Kumar; Mehtab, Sameena; Singh, Udai P; Aggarwal, Vaibhave

    2007-08-01

    Potassium hydrotris(N-tert-butyl-2-thioimidazolyl)borate [KTtt-Bu] and potassium hydrotris(3-tert-butyl-5-isopropyl-l-pyrazolyl)borate [KTpt-Bu,i-Pr] have been synthesized and evaluated as ionophores for preparation of a poly(vinyl chloride) (PVC) membrane sensor for Zn(II) ions. The effect of different plasticizers, viz. benzyl acetate (BA), dioctyl phthalate (DOP), dibutyl phthalate (DBP), tributyl phosphate (TBP), and o-nitrophenyl octyl ether (o-NPOE), and the anion excluders sodium tetraphenylborate (NaTPB), potassium tetrakis(p-chlorophenyl)borate (KTpClPB), and oleic acid (OA) were studied to improve the performance of the membrane sensor. The best performance was obtained from a sensor with a of [KTtt-Bu] membrane of composition (mg): [KTtt-Bu] (15), PVC (150), DBP (275), and NaTPB (4). This sensor had a Nernstian response (slope, 29.4+/-0.2 mV decade of activity) for Zn2+ ions over a wide concentration range (1.4x10(-7) to 1.0x10(-1) mol L(-1)) with a limit of detection of 9.5x10(-8) mol L(-1). It had a relatively fast response time (12 s) and could be used for 3 months without substantial change of the potential. The membrane sensor had very good selectivity for Zn2+ ions over a wide variety of other cations and could be used in a working pH range of 3.5-7.8. The sensor was also found to work satisfactorily in partially non-aqueous media and could be successfully used for estimation of zinc at trace levels in biological and environmental samples. PMID:17622519

  13. Target and non-target screening strategies for organic contaminants, residues and illicit substances in food , environmental and human biological samples by UHPLC-QTOF-MS

    OpenAIRE

    Hernández Hernández, Félix; Díaz San Pedro, Ramón; Sancho Llopis, Juan Vicente; Ibáñez Martínez, María

    2012-01-01

    In this paper, we illustrate the potential of ultra-high performance liquid chromatography (UHPLC) coupled with hybrid quadrupole time-of-flight mass spectrometry (QTOF MS) for large scale screening of organic contaminants in different types of samples. Thanks to the full-spectrum acquisition at satisfactory sensitivity, it is feasible to apply both (post)-target and non-target approaches for the rapid qualitative screening of organic pollutants in food, biological and environmental samples. ...

  14. Experiences performed at the C:R: Saluggia of ENEA in low-level determination of plutonium in biological and environmental samples

    International Nuclear Information System (INIS)

    This report describes some experiences performed at the Research Center Saluggia of ENEA concerning low-level determination of plutonium in biological and environmental samples, with discussions of practical analytical problems. The main characteristics and properties of plutonium with emphasis to aqueous solutions chemistry and environmental behaviour are also reported

  15. TRLFS Studies on Indirect Determination of U(IV) in Biological Samples Containing Mixed U(IV/VI) Species

    International Nuclear Information System (INIS)

    The microbial-mediated metal reduction process has been viewed as a long-term remedial approach for in situ immobilization of radionuclide under anaerobic conditions in aquifers and saturated soils. Such approach depends on the fact that many radionuclides of concern including uranium are redox active and less soluble in their reduced form. Thus, the interaction of uranium with microorganisms has been the subject of considerable effort over the past decade. Uranium reduction occurs as a result of dynamic metabolic activity of microbials and biochemical reactions. The typical incubation system of uranium reducing bacteria such as sulfate-reducing Desulfovibrionales contains various geochemical components including electron donors (e.g., acetate, lactate, ethanol, thiol or glucose), anionic electron acceptors (sulfate and nitrate) and metal ions (Fe(II/III), Mn, Ni, etc.). The anoxic growth of bacteria results in uranium reduction by forming U(IV) aggregates or colloids. In most studies the isolation of U(IV) from U(VI) largely depends on filtration of precipitates and centrifugal separation of colloidal particles. Such U(IV) species were subsequently analyzed via ICP-MS for elemental uranium or kinetic phosphorescence analysis (KPA) in form of U(VI) although the relative proportion of U(IV) and U(VI) in the frozen samples can be estimated using X-ray absorption spectroscopy. However, recent studies report the formation of extracellular uranite nanoparticles, which may suspend in the resultant filtrate and supernatant solutions. Thus, the development of an analytical technique capable of estimating the dissolved or suspended U(IV) species is further required for better understanding of the bacterial-mediated uranium sequestration and dissolution process. In this study we explore the possibility of using TRLFS (time-resolved laser-induced fluorescence spectroscopy) to indirectly measure the concentration of U(IV) as well as that of U(VI) in bacterial culture media

  16. Marco Polo - a mission to return a sample from a Near-Earth Object - science requirements and operational scenarios

    OpenAIRE

    Koschny, Detlef; Barucci, Antonella; Yoshikawa, Makoto; Böhnhardt, Hermann; Brucato, John; Coradini, Marcello; Dotto, Elisabetta; Franchi, Ian; Green, Simon F.; Josset, Jean-Luc; Kawaguchi, Junichiro; Michel, Patrick; Muinonen, Karri; Oberst, Jürgen; Yano, Hajime

    2009-01-01

    Marco Polo is a mission to return a sample from a Near-Earth Object of primitive type (class C or D). It is foreseen as a collaborative effort between the Japanese Space Agency (JAXA) and the European Space Agency (ESA). Marco Polo is currently in a Phase-A study. This paper focuses on the scientific requirements provided to the industrial study consortia in Europe as well as the possible mission scenario at the target object in order to achieve the overall mission science objectives. The ...

  17. [Micro-determination of fluoride in biological samples by pyrohydrolysis and flow-injection analysis using a fluoride ion-selective electrode].

    Science.gov (United States)

    Itai, K

    1991-02-01

    An apparatus has been developed for the isolation of fluoride in biological samples through pyrohydrolysis. With this apparatus, it is possible to determine both organic and inorganic fluorocompounds with a recovery close to 100% and precision within 5%. The high recovery rate can be expected even for highly heat-resistant compounds such as CaF2, without using WO3 as a catalyst. For determination of the isolated fluoride, a separate apparatus was developed in which flow-injection analysis was used in conjunction with a fluoride ion-selective electrode as a detector. With this apparatus, fluoride in a sample solution with a volume as small as 0.2 ml, and at a concentration as low as 0.5 microgram/l, can be determined within 3 minutes with a precision of several percent. Combined use of the two apparatuses makes it possible to determine fluoride in different biological samples within 10-15 minutes with a precision of several percent, free from external contamination. By selecting suitable conditions for analysis and using a 1 g sample, it is possible to determine fluoride at a concentration as low as 5 ng/g. By employing these apparatuses, the fluoride content in different biological samples has been determine and the effectiveness of their use confirmed. PMID:2051632

  18. Sample preparation for inductively coupled plasma mass spectrometric determination of the zinc-70 to zinc-68 isotope ratio in biological samples

    International Nuclear Information System (INIS)

    Sample preparation was optimized for the 70Zn:68Zn isotope ratio determinations performed with inductively coupled plasma mass spectrometry in blood, faeces and urine from human pre-term babies after oral or intravenous administration of enriched 70Zn. The preparation techniques achieved complete decomposition, matrix separation, maximum preconcentration and minimum contamination. After sample decomposition, Zn was extracted into CCl4 with ammonium pyrrolidin-1-yldithioformate and back extracted into 1.2 mol dm-3 HNO3 for analysis. Residual chloride resulting from dissolved CCl4 in the acid led to interference by 35Cl2+, and the procedure was modified to evaporate the CCl4. Extraction was unnecessary for faecal samples. Under optimized conditions the 70Zn:68Zn isotope ratio can be measured with acceptable precision (200 ng cm-3 in the analytical solution). (Author)

  19. Development of a Univariate Membrane-Based Mid-Infrared Method for Protein Quantitation and Total Lipid Content Analysis of Biological Samples

    Directory of Open Access Journals (Sweden)

    Ivona Strug

    2014-01-01

    Full Text Available Biological samples present a range of complexities from homogeneous purified protein to multicomponent mixtures. Accurate qualification of such samples is paramount to downstream applications. We describe the development of an MIR spectroscopy-based analytical method offering simultaneous protein quantitation (0.25–5 mg/mL and analysis of total lipid or detergent species, as well as the identification of other biomolecules present in biological samples. The method utilizes a hydrophilic PTFE membrane engineered for presentation of aqueous samples in a dried format compatible with fast infrared analysis. Unlike classical quantification techniques, the reported method is amino acid sequence independent and thus applicable to complex samples of unknown composition. By comparison to existing platforms, this MIR-based method enables direct quantification using minimal sample volume (2 µL; it is well-suited where repeat access and limited sample size are critical parameters. Further, accurate results can be derived without specialized training or knowledge of IR spectroscopy. Overall, the simplified application and analysis system provides a more cost-effective alternative to high-throughput IR systems for research laboratories with minimal throughput demands. In summary, the MIR-based system provides a viable alternative to current protein quantitation methods; it also uniquely offers simultaneous qualification of other components, notably lipids and detergents.

  20. Polymer monolithic capillary microextraction on-line coupled with inductively coupled plasma-mass spectrometry for the determination of trace Au and Pd in biological samples

    Science.gov (United States)

    Liu, Xiaolan; He, Man; Chen, Beibei; Hu, Bin

    2014-11-01

    A novel method based on on-line polymer monolithic capillary microextraction (CME)-inductively coupled plasma mass spectrometry (ICP-MS) was developed for the determination of trace Au and Pd in biological samples. For this purpose, poly(glycidyl methacrylate-ethylene dimethacrylate) monolith was prepared and functionalized with mercapto groups. The prepared monolith exhibited good selectivity to Au and Pd, and good resistance to strong acid with a long life span. Factors affecting the extraction efficiency of CME, such as sample acidity, sample flow rate, eluent conditions and coexisting ion interference were investigated in detail. Under the optimal conditions, the limits of detection (LODs, 3σ) were 5.9 ng L- 1 for Au and 8.3 ng L- 1 for Pd, and the relative standard deviations (RSDs, c = 50 ng L -1, n = 7) were 6.5% for Au and 1.1% for Pd, respectively. The developed method was successfully applied to the determination of Au and Pd in human urine and serum samples with the recovery in the range of 84-118% for spiked samples. The developed on-line polymer monolithic CME-ICP-MS method has the advantages of rapidity, simplicity, low sample/reagent consumption, high sensitivity and is suitable for the determination of trace Au and Pd in biological samples with limited amount available and complex matrix.

  1. Intercomparison of inductively coupled plasma mass spectrometry, quantitative neutron capture radiography, and prompt gamma activation analysis for the determination of boron in biological samples.

    Science.gov (United States)

    Schütz, C L; Brochhausen, C; Hampel, G; Iffland, D; Kuczewski, B; Otto, G; Schmitz, T; Stieghorst, C; Kratz, J V

    2012-10-01

    Boron determination in blood and tissue samples is a crucial task especially for treatment planning, preclinical research, and clinical application of boron neutron capture therapy (BNCT). Comparison of clinical findings remains difficult due to a variety of analytical methods, protocols, and standard reference materials in use. This paper addresses the comparability of inductively coupled plasma mass spectrometry, quantitative neutron capture radiography, and prompt gamma activation analysis for the determination of boron in biological samples. It was possible to demonstrate that three different methods relying on three different principles of sample preparation and boron detection can be validated against each other and yield consistent results for both blood and tissue samples. The samples were obtained during a clinical study for the application of BNCT for liver malignancies and therefore represent a realistic situation for boron analysis. PMID:22918535

  2. Intercomparison of inductively coupled plasma mass spectrometry, quantitative neutron capture radiography, and prompt gamma activation analysis for the determination of boron in biological samples

    Energy Technology Data Exchange (ETDEWEB)

    Schuetz, C.L. [University of Mainz, Institute for Nuclear Chemistry, Mainz (Germany); Johannes Gutenberg-University of Mainz, Institute for Nuclear Chemistry, Mainz (Germany); Brochhausen, C. [University of Mainz, Institute of Pathology, Mainz (Germany); Hampel, G.; Iffland, D.; Schmitz, T.; Stieghorst, C.; Kratz, J.V. [University of Mainz, Institute for Nuclear Chemistry, Mainz (Germany); Kuczewski, B. [Regional Council Darmstadt, Darmstadt (Germany); Otto, G. [University of Mainz, Department of Hepatobiliary, Pancreatic and Transplantation Surgery, Mainz (Germany)

    2012-10-15

    Boron determination in blood and tissue samples is a crucial task especially for treatment planning, preclinical research, and clinical application of boron neutron capture therapy (BNCT). Comparison of clinical findings remains difficult due to a variety of analytical methods, protocols, and standard reference materials in use. This paper addresses the comparability of inductively coupled plasma mass spectrometry, quantitative neutron capture radiography, and prompt gamma activation analysis for the determination of boron in biological samples. It was possible to demonstrate that three different methods relying on three different principles of sample preparation and boron detection can be validated against each other and yield consistent results for both blood and tissue samples. The samples were obtained during a clinical study for the application of BNCT for liver malignancies and therefore represent a realistic situation for boron analysis. (orig.)

  3. Intercomparison of inductively coupled plasma mass spectrometry, quantitative neutron capture radiography, and prompt gamma activation analysis for the determination of boron in biological samples

    International Nuclear Information System (INIS)

    Boron determination in blood and tissue samples is a crucial task especially for treatment planning, preclinical research, and clinical application of boron neutron capture therapy (BNCT). Comparison of clinical findings remains difficult due to a variety of analytical methods, protocols, and standard reference materials in use. This paper addresses the comparability of inductively coupled plasma mass spectrometry, quantitative neutron capture radiography, and prompt gamma activation analysis for the determination of boron in biological samples. It was possible to demonstrate that three different methods relying on three different principles of sample preparation and boron detection can be validated against each other and yield consistent results for both blood and tissue samples. The samples were obtained during a clinical study for the application of BNCT for liver malignancies and therefore represent a realistic situation for boron analysis. (orig.)

  4. Gene-ontology enrichment analysis in two independent family-based samples highlights biologically plausible processes for autism spectrum disorders.

    LENUS (Irish Health Repository)

    Anney, Richard J L

    2012-02-01

    Recent genome-wide association studies (GWAS) have implicated a range of genes from discrete biological pathways in the aetiology of autism. However, despite the strong influence of genetic factors, association studies have yet to identify statistically robust, replicated major effect genes or SNPs. We apply the principle of the SNP ratio test methodology described by O\\'Dushlaine et al to over 2100 families from the Autism Genome Project (AGP). Using a two-stage design we examine association enrichment in 5955 unique gene-ontology classifications across four groupings based on two phenotypic and two ancestral classifications. Based on estimates from simulation we identify excess of association enrichment across all analyses. We observe enrichment in association for sets of genes involved in diverse biological processes, including pyruvate metabolism, transcription factor activation, cell-signalling and cell-cycle regulation. Both genes and processes that show enrichment have previously been examined in autistic disorders and offer biologically plausibility to these findings.

  5. Cryogenic coherent X-ray diffraction imaging of biological samples at SACLA: a correlative approach with cryo-electron and light microscopy.

    Science.gov (United States)

    Takayama, Yuki; Yonekura, Koji

    2016-03-01

    Coherent X-ray diffraction imaging at cryogenic temperature (cryo-CXDI) allows the analysis of internal structures of unstained, non-crystalline, whole biological samples in micrometre to sub-micrometre dimensions. Targets include cells and cell organelles. This approach involves preparing frozen-hydrated samples under controlled humidity, transferring the samples to a cryo-stage inside a vacuum chamber of a diffractometer, and then exposing the samples to coherent X-rays. Since 2012, cryo-coherent diffraction imaging (CDI) experiments have been carried out with the X-ray free-electron laser (XFEL) at the SPring-8 Ångstrom Compact free-electron LAser (SACLA) facility in Japan. Complementary use of cryo-electron microscopy and/or light microscopy is highly beneficial for both pre-checking samples and studying the integrity or nature of the sample. This article reports the authors' experience in cryo-XFEL-CDI of biological cells and organelles at SACLA, and describes an attempt towards reliable and higher-resolution reconstructions, including signal enhancement with strong scatterers and Patterson-search phasing. PMID:26919369

  6. Application of a powdered-internal-standard method combined with correction for self-absorption of x-rays to geological, environmental and biological samples

    International Nuclear Information System (INIS)

    Availability of a powdered internal standard method developed in the previous report has been investigated in detail for geological, mineralogical, environmental and biological samples. It is found that this method is effective for various powdered samples composed of high-Z elements. A computer program for correcting self-absorption of x-rays, which is based on the method we previously reported, was developed and it has been applied to soil samples of varied thickness. As a result, it is found that the method is quite effective even for a pretty thick target where particles overlap with each other. Moreover, the method was applied to several rock samples, which were prepared by grinding and consist of particles of divergent size, and found to be applicable. Lastly, the powered internal standard method was applied to a biological sample and found to be almost satisfactory, too. These results demonstrate the availability of the powdered internal standard method combined with the method of x-ray-absorption correction for samples in many research fields. (author)

  7. OXI-FLO: an instrument concept for the combined sample preparation and measurement of low energy beta radio-labelled biological samples

    International Nuclear Information System (INIS)

    The purpose of the development of the OXI-FLO instrument was to provide an automated system which will produce accurate, reproducible results at a cost which is competitive with current techniques, but which also provides savings in labor. An oxidizer, coupled with a liquid scintillation counter (LSC) has many advantages. The techniques of vial-less LSC was pioneered in this company, during the development of the RSP-β400 Sample Processor, therefore, the technology of transferring and counting a liquid in a stop-flow mode was readily available. The OXI-ONE Sample Oxidizer, also marketed by Radiomatic Instruments, lends itself naturally to the OXI-FLO concept, since the LSC vial is not an integral part of the oxidizer and can be substituted with a different device. These two technologies combined are the basis of the OXI-FLO instrument

  8. Ultra-Sensitive Elemental Analysis Using Plasmas 5.Speciation of Arsenic Compounds in Biological Samples by High Performance Liquid Chromatography-Inductively Coupled Plasma Mass Spectrometry System

    Science.gov (United States)

    Kaise, Toshikazu

    Arsenic originating from the lithosphere is widely distributed in the environment. Many arsenicals in the environment are in organic and methylated species. These arsenic compounds in drinking water or food products of marine origin are absorbed in human digestive tracts, metabolized in the human body, and excreted viatheurine. Because arsenic shows varying biological a spects depending on its chemical species, the biological characteristics of arsenic must be determined. It is thought that some metabolic pathways for arsenic and some arsenic circulation exist in aqueous ecosystems. In this paper, the current status of the speciation analysis of arsenic by HPLC/ICP-MS (High Performance Liquid Chromatography-Inductively Coupled Plasma Mass spectrometry) in environmental and biological samples is summarized using recent data.

  9. Critical comparison of radiometric and mass spectrometric methods for the determination of radionuclides in environmental, biological and nuclear waste samples

    DEFF Research Database (Denmark)

    Hou, Xiaolin; Roos, Per

    2008-01-01

    application in the environmental and biological researches, these radionuclides include H-3, C-14, Cl-36, Ca-41 Ni-59,Ni-63, Sr-89,Sr-90, Tc-99, I-129, Cs-135,Cs-137, Pb-210, Ra-226,Ra-228, Np-237, Am-241, and isotopes of thorium, uranium and plutonium. The application of on-line methods (flow injection...

  10. Integrating Math & Computer Skills in the Biology Classroom: An Example Using Spreadsheet Simulations to Teach Fundamental Sampling Concepts

    Science.gov (United States)

    Ray, Darrell L.

    2013-01-01

    Students often enter biology programs deficient in the math and computational skills that would enhance their attainment of a deeper understanding of the discipline. To address some of these concerns, I developed a series of spreadsheet simulation exercises that focus on some of the mathematical foundations of scientific inquiry and the benefits…

  11. Simultaneous multi-species determination of trimethyllead, monomethylmercury and three butyltin compounds by species-specific isotope dilution GC-ICP-MS in biological samples.

    Science.gov (United States)

    Poperechna, Nataliya; Heumann, Klaus G

    2005-09-01

    An accurate and sensitive multi-species species-specific isotope dilution GC-ICP-MS method was developed for the simultaneous determination of trimethyllead (Me3Pb+), monomethylmercury (MeHg+) and the three butyltin species Bu3Sn+, Bu2Sn2+, and BuSn3+ in biological samples. The method was validated by three biological reference materials (CRM 477, mussel tissue certified for butyltins; CRM 463, tuna fish certified for MeHg+; DORM 2, dogfish muscle certified for MeHg+). Under certain conditions, and with minor modifications of the sample pretreatment procedure, this method could also be transferred to environmental samples such as sediments, as demonstrated by analyzing sediment reference material BCR 646 (freshwater sediment, certified for butyltins). The detection limits of the multi-species GC-ICP-IDMS method for biological samples were 1.4 ng g(-1) for MeHg+, 0.06 ng g(-1) for Me3Pb+, 0.3 ng g(-1) for BuSn3+ and Bu3Sn+, and 1.2 ng g(-1) for Bu2Sn2+. Because of the high relevance of these heavy metal alkyl species to the quality assurance of seafood, the method was also applied to corresponding samples purchased from a supermarket. The methylated lead fraction in these samples, correlated to total lead, varied over a broad range (from 0.01% to 7.6%). On the other hand, the MeHg+ fraction was much higher, normally in the range of 80-100%. Considering that we may expect tighter legislative limitations on MeHg+ levels in seafood in the future, we found the highest methylmercury contents (up to 10.6 microg g(-1)) in two shark samples, an animal which is at the end of the marine food chain, whereas MeHg+ contents of less than 0.2 microg g(-1) were found in most other seafood samples; these results correlate with the idea that MeHg+ is usually of biological origin in the marine environment. The concentration of butyltins and the fraction of the total tin content that is from butyltins strongly depend on possible contamination, due to the exclusively anthropogenic

  12. Computed partial neutron cross-sections of 51V at 14 MeV for trace elemental analysis of biological samples

    International Nuclear Information System (INIS)

    The present paper describes the primary and secondary computed partial neutron reaction cross-sections at 14 MeV for 51V. The computations are based on the compound nucleus theory using an optical model potential and Newton's shell-dependent level density formula. The computed partial cross-sections have been compared with the available experimental values and are fairly in good agreement. These cross-sections have been used for the trace elemental analysis of biological samples like brain, muscle, liver, testes, lung, lymph nodes and blood of human subjects. The induced β-activity per gram of above biological samples per unit neutron flux have been computed for the reactions 51V(n,p)51Tisup(*) with Tsub(1/2)=5.8 min and 51V(n,α)48Scsup(*) with Tsub(1/2)=1.81 days and are tabulated. (author). 12 refs

  13. Preparation of biological samples for transmission X-ray microanalysis: a review of alternative procedures to the use of sectioned material

    International Nuclear Information System (INIS)

    Although transmission X-ray microanalysis of biological material has traditionally been carried out mainly on sectioned preparations, a number of alternative procedures exist. These are considered under three major headings - whole cell preparations, analysis of cell homogenates and biological fluids, and applications of the technique to microsamples of purified biochemicals. These three aspects provide a continuous range of investigative level - from the cellular to the molecular. The use of X-ray microanalysis with whole cell preparations is considered in reference to eukaryote (animal) cells and prokaryotes - where it has particular potential in environmental studies on bacteria. In the case of cell homogenates and biological fluids, the technique has been used mainly with microdroplets of animal material. The use of X-ray microanalysis with purified biochemicals is considered in relation to both particulate and non-particulate samples. In the latter category, the application of this technique for analysis of thin films of metalloprotein is particularly emphasised. It is concluded that wider use could be made of the range of preparative techniques available - both within a particular investigation, and in diverse fields of study. Transmission X-ray microanalysis has implications for environmental, physiological and molecular biology as well as cell biology

  14. A novel solid-phase microextraction method based on polymer monolith frit combining with high-performance liquid chromatography for determination of aldehydes in biological samples.

    Science.gov (United States)

    Xu, Hui; Wang, Shuyu; Zhang, Ganbing; Huang, Shiqiang; Song, Dandan; Zhou, Yanping; Long, Guangdou

    2011-03-25

    In this work, a polypropylene frit with porous network structure (20 μm pole size) was first utilized as the mould of polymer monolithic material, poly(methacrylic acid-co-ethylene glycol dimethacrylate) (MAA-co-EDMA) monolith was synthesized within channels and macropores of the frit. A simple and sensitive solid-phase microextraction method based on polymer monolith frit coupled with high-performance liquid chromatography (HPLC) was established and applied to analysis of hexanal and heptanal in biological samples (human urine and serum). In the method, small molecule metabolites (aldehydes) in biological samples derivatized with 2,4-dinitrophenylhydrazine (DNPH), and the formed hydrazones were extracted simultaneously on the monolithic frit and thereafter ultrasound-assisted desorbed with acetonitrile as elution solvent. The experimental parameters with regard to polymerization, derivatization and extraction were investigated. Under the optimal conditions, the linearity was in the range of 0.02-5.0 μmol L(-1) (r=0.9994) for both hexanal and heptanal and the limits of detection (S/N=3) were 0.81 nmol L(-1) for hexanal and 0.76 nmol L(-1) for heptanal. The relative standard deviations (RSDs, n=5) were less than 6.5% for the same monolithic frit and less than 8.9% for the different monolithic frits. Satisfactory recoveries ranging from 70.71% to 88.73% were obtained for the urine samples. The method possesses many advantages including simple setup, fast analysis, low cost, sufficient sensitivity, good biological compatibility and less organic solvent consumption. The proposed method is a useful assistant tool in the clinical early diagnosis of lung disease by monitoring aldehyde biomarker candidates in complex biological samples. PMID:21414440

  15. Systematic Analysis of Main Constituents in Rat Biological Samples after Oral Administration of the Methanol Extract of Fructus Aurantii by HPLC-ESI-MS/MS

    OpenAIRE

    Zhang, Jingze; Gao, Wenyuan; Liu, Zhen; Zhang, Zhidan; Liu, Changxiao

    2014-01-01

    High performance liquid chromatography (HPLC) with diode array detection (DAD) and electrospray ionization tandem mass spectrometry (ESI/MS/MS) was used to analyze the main components in the methanol extract of Fructus Aurantii (FA) and the metabolites in rat biological samples after oral administration of the methanol extract of FA. There were 31 constituents identified in the extract of FA including 2 alkaloids, 1 coumarin, 10 flavonoid glycosides and 18 ploymethoxylated flavones. According...

  16. Harmonically matched grating-based full-field quantitative high-resolution phase microscope for observing dynamics of transparent biological samples

    OpenAIRE

    Wu, Jigang; Yaqoob, Zahid; Heng, Xin; Yang, Changhuei

    2007-01-01

    We have developed a full-field high resolution quantitative phase imaging technique for observing dynamics of transparent biological samples. By using a harmonically matched diffraction grating pair (600 and 1200 lines/mm), we were able to obtain non-trivial phase difference (other than 0° or 180°) between the output ports of the gratings. Improving upon our previous design, our current system mitigates astigmatism artifacts and is capable of high resolution imaging. This system also em...

  17. Determination of Nitric Oxide-Derived Nitrite and Nitrate in Biological Samples by HPLC Coupled to Nitrite Oxidation

    OpenAIRE

    Wu, Anguo; Duan, Tingting; Tang, Dan; Xu, Youhua; Feng, Liang; Zheng, Zhaoguang; Zhu, Jiaxiao; Wang, Rushang; Zhu, Quan

    2013-01-01

    Nitrite and nitrate are main stable products of nitric oxide, a pivotal cellular signaling molecule, in biological fluids. Therefore, accurate measurement of the two ions is profoundly important. Nitrite is difficult to be determined for a larger number of interferences and unstable in the presence of oxygen. In this paper, a simple, cost-effective and accurate HPLC method for the determination of nitrite and nitrate was developed. On the basis of the reaction that nitrite is oxidized rapidly...

  18. Polymer monolithic capillary microextraction on-line coupled with inductively coupled plasma-mass spectrometry for the determination of trace Au and Pd in biological samples

    International Nuclear Information System (INIS)

    A novel method based on on-line polymer monolithic capillary microextraction (CME)-inductively coupled plasma mass spectrometry (ICP-MS) was developed for the determination of trace Au and Pd in biological samples. For this purpose, poly(glycidyl methacrylate-ethylene dimethacrylate) monolith was prepared and functionalized with mercapto groups. The prepared monolith exhibited good selectivity to Au and Pd, and good resistance to strong acid with a long life span. Factors affecting the extraction efficiency of CME, such as sample acidity, sample flow rate, eluent conditions and coexisting ion interference were investigated in detail. Under the optimal conditions, the limits of detection (LODs, 3σ) were 5.9 ng L−1 for Au and 8.3 ng L−1 for Pd, and the relative standard deviations (RSDs, c = 50 ng L−1, n = 7) were 6.5% for Au and 1.1% for Pd, respectively. The developed method was successfully applied to the determination of Au and Pd in human urine and serum samples with the recovery in the range of 84–118% for spiked samples. The developed on-line polymer monolithic CME-ICP-MS method has the advantages of rapidity, simplicity, low sample/reagent consumption, high sensitivity and is suitable for the determination of trace Au and Pd in biological samples with limited amount available and complex matrix. - Highlights: • An on-line CME-ICP-MS method was developed for Au and Pd analysis in human fluids. • Poly(GMA-EDMA-SH) monolith exhibited good selectivity for Au/Pd and acid-resistance. • The method is rapid, simple, and sensitive with low sample/reagents consumption

  19. Estimation of lead in biological samples of oral cancer patients chewing smokeless tobacco products by ionic liquid-based microextraction in a single syringe system.

    Science.gov (United States)

    Arain, Sadaf S; Kazi, Tasneem G; Arain, Asma J; Afridi, Hassan I; Arain, Muhammad B; Brahman, Kapil D; Naeemullah; Panhwar, Abdul H; Arain, Mariam S

    2015-08-01

    Several studies have reported that the chewing habit of smokeless tobacco (SLT) has been associated with oral cancer. The aim of the present study was to evaluate the trace levels of lead (Pb) in biological samples (blood, scalp hair) of oral cancer patients and referents of the same age group (range 30-60 years). As the concentrations of Pb are very low in biological samples, so a simple and efficient ionic liquid-based microextraction in a single syringe system has been developed, as a prior step to determination by flame atomic absorption spectrometry. In this procedure, the hydrophobic chelates of Pb with ammonium pyrrolidinedithiocarbamate (APDC) were extracted into fine droplets of 1-butyl-3-methylimidazolium hexafluorophosphate [C4MIM][PF6] within a syringe while using Triton X-114 as a dispersant. Factors influencing the microextraction efficiency and determination, such as pH of the sample, volume of [C4MIM][PF6] and Triton X-114, ligand concentration, and incubation time, were studied. To validate the proposed method, certified reference materials were analyzed and the results of Pb(2+) were in good agreement with certified values. At optimum experimental values of significant variables, detection limit and enhancement factor were found to be 0.412 μg/L and 80, respectively. The coexisting ions showed no obvious negative outcome on Pb preconcentration. The proposed method was applied satisfactorily for the preconcentration of Pb(2+) in acid-digested SLT and biological samples of the study population. It was observed that oral cancer patients who consumed different SLT products have 2-3-fold higher levels of Pb in scalp hair and blood samples as compared to healthy referents (p < 0.001). While 31.4-50.8% higher levels of Pb were observed in referents chewing different SLT products as compared to nonconsumers (p < 0.01). PMID:25903188

  20. Guidance for the management of patients with latent tuberculosis infection requiring biologic therapy in rheumatology and dermatology clinical practice.

    Science.gov (United States)

    Cantini, Fabrizio; Nannini, Carlotta; Niccoli, Laura; Iannone, Florenzo; Delogu, Giovanni; Garlaschi, Giacomo; Sanduzzi, Alessandro; Matucci, Andrea; Prignano, Francesca; Conversano, Michele; Goletti, Delia

    2015-06-01

    Since the introduction of biologics for the treatment of rheumatoid arthritis (RA), psoriatic arthritis (PsA), ankylosing spondylitis (AS), and psoriasis (Pso) an increased risk of tuberculosis (TB) reactivation in patients with latent tuberculosis infection (LTBI) has been recorded for anti-TNF agents, while a low or absent risk is associated with the non-anti-TNF targeted biologics. To reduce this risk several recommendation sets have been published over time, but in most of them the host-related risk, and the predisposing role to TB reactivation exerted by corticosteroids and by the traditional disease-modifying anti-rheumatic drugs has not been adequately addressed. Moreover, the management of the underlying disease, and the timing of biologic restarting in patients with TB occurrence have been rarely indicated. A multidisciplinary expert panel, the Italian multidisciplinary task force for screening of tuberculosis before and during biologic therapy (SAFEBIO), was constituted, and through a review of the literature, an evidence-based guidance for LTBI detection, identification of the individualized level of risk of TB reactivation, and practical management of patients with TB occurrence was formulated. The literature review confirmed a higher TB risk associated with monoclonal anti-TNF agents, a low risk for soluble receptor etanercept, and a low or absent risk for non-anti-TNF targeted biologics. Considering the TB reactivation risk associated with host demographic and clinical features, and previous or current non-biologic therapies, a low, intermediate, or high TB reactivation risk in the single patient was identified, thus driving the safest biologic choice. Moreover, based on the underlying disease activity measurement and the different TB risk associated with non-biologic and biologic therapies, practical indications for the treatment of RA, PsA, AS, and Pso in patients with TB occurrence, as well as the safest timing of biologic restarting, were provided

  1. Strontium-90 determination in biological and environmental samples by direct milking of its daughter product, yttrium-90

    International Nuclear Information System (INIS)

    A method is presented for the determination of 90Sr in environmental samples by direct milking of 90Y. Pyridine-2,6-dicarboxylic acid forms an anionic complex with yttrium which is retained on an anionic resin. Most of the matrix elements are washed out of the column as neutral or uncomplexed species and yttrium is eluted by increasing the ionic force of the eluent solution. This method gives yttrium recoveries between 65% to 85% for soil, grass, milk and bone samples with very high radiochemical purity (90Y average half-life of 66 ± 4 hours) and a detection limit of 0.3 Bq/kg of soil. The method supports a calcium content up to 3 g per sample without any decrease in yttrium yield, allowing the measurement of milk, milk-teeth and bone samples with no concentration step in one day. (author)

  2. Public views on the donation and use of human biological samples in biomedical research: a mixed methods study

    OpenAIRE

    Lewis, C.; Clotworthy, M.; Hilton, S; MaGee, C.; Robertson, M. J.; Stubbins, L.J.; Corfield, J.

    2013-01-01

    Objective A mixed methods study exploring the UK general public's willingness to donate human biosamples (HBSs) for biomedical research. Setting Cross-sectional focus groups followed by an online survey. Participants Twelve focus groups (81 participants) selectively sampled to reflect a range of demographic groups; 1110 survey responders recruited through a stratified sampling method with quotas set on sex, age, geographical location, socioeconomic group and ethnicity. Main outcom...

  3. Implementación de un protocolo de actuación para toma de muestras biológicas en juicios de paternidad/Implementation of a protocol for sampling biological tasters in trials of paternity

    Directory of Open Access Journals (Sweden)

    Daniel De La Barrera Escamilla

    2015-01-01

    Full Text Available The scientific and technological advances in forensic research has resulted in recent years in the use of various scientific applications such as Forensic Genetic; the possibility that this area is critical to the identification of persons and the establishment of biological relationship. Since in Mexico, expert evidence on Molecular and Forensic Genetics used in in family and civil trial´s matters, in order to recognize the relationship between individuals has a little over 10 years to be used actively, it is necessary that forensic experts involved in these judgments have a sampling protocol to ensure technical and legally correct way sample collection; and ensure safekeeping and processing them in the laboratory, the aim of which is meet the new requirements of orality.

  4. Quantitative evaluation of freeze-substitution effects on preservation of nuclear antigens during preparation of biological samples for immunoelectron microscopy

    Czech Academy of Sciences Publication Activity Database

    Sobol, Margaryta; Philimonenko, Vlada; Philimonenko, Anatoly; Hozák, Pavel

    2012-01-01

    Roč. 138, č. 1 (2012), s. 167-177. ISSN 0948-6143 R&D Projects: GA AV ČR KAN200520704; GA MŠk 2B06063; GA MŠk LC545; GA ČR GAP305/11/2232 Institutional research plan: CEZ:AV0Z50520514 Keywords : immuno-gold labeling * automated freeze-substitution * LR White * immunohistochemistry * high-pressure freezing Subject RIV: EB - Genetics ; Molecular Biology Impact factor: 2.613, year: 2012

  5. The influence of psychoeducation on regulating biological rhythm in a sample of patients with bipolar II disorder: a randomized clinical trial

    Directory of Open Access Journals (Sweden)

    Faria AD

    2014-06-01

    Full Text Available Augusto Duarte Faria,1 Luciano Dias de Mattos Souza,2 Taiane de Azevedo Cardoso,2 Karen Amaral Tavares Pinheiro,2 Ricardo Tavares Pinheiro,2 Ricardo Azevedo da Silva,2 Karen Jansen21Department of Clinical and Health Psychology, Universidade Federal do Rio Grande – FURG, Rio Grande, RS, Brazil; 2Health and Behavior Postgraduate Program, Universidade Católica de Pelotas – UCPEL, Pelotas, RS, BrazilIntroduction: Changes in biological rhythm are among the various characteristics of bipolar disorder, and have long been associated with the functional impairment of the disease. There are only a few viable options of psychosocial interventions that deal with this specific topic; one of them is psychoeducation, a model that, although it has been used by practitioners for some time, only recently have studies shown its efficacy in clinical practice.Aim: To assess if patients undergoing psychosocial intervention in addition to a pharmacological treatment have better regulation of their biological rhythm than those only using medication.Method: This study is a randomized clinical trial that compares a standard medication intervention to an intervention combined with drugs and psychoeducation. The evaluation of the biological rhythm was made using the Biological Rhythm Interview of Assessment in Neuropsychiatry, an 18-item scale divided in four areas (sleep, activity, social rhythm, and eating pattern. The combined intervention consisted of medication and a short-term psychoeducation model summarized in a protocol of six individual sessions of 1 hour each.Results: The sample consisted of 61 patients with bipolar II disorder, but during the study, there were 14 losses to follow-up. Therefore, the final sample consisted of 45 individuals (26 for standard intervention and 19 for combined. The results showed that, in this sample and time period evaluated, the combined treatment of medication and psychoeducation had no statistically significant impact on the

  6. Applied research and development of neutron activation analysis - The study on human health and environment by neutron activation analysis of biological samples

    Energy Technology Data Exchange (ETDEWEB)

    Cho, Seung Yeon; Yoo, Jong Ik; Lee, Jae Kwang; Lee, Sung Jun; Lee, Sang Sun; Jeon, Ki Hong; Na, Kyung Won; Kang, Sang Hun [Yonsei University, Seoul (Korea)

    2000-04-01

    With the development of the precise quantitative analytical method for the analysis of trace elements in the various biological samples such as hair and food, evaluation in view of health and environment to the trace elements in various sources which can be introduced inside human body was done. The trace elemental distribution in Korean total diet and representative food stuff was identified first. With the project the elemental distributions in supplemental healthy food and Korean and Chinese origin oriental medicine were identified. The amount of trace elements ingested with the hair analysis of oriental medicine takers were also estimated. The amounts of trace elements inhaled with the analysis of foundry air, blood and hair of foundry workers were also estimated. The basic estimation method in view of health and environment with the neutron activation analysis of biological samples such as foods and hair was established with the result. Nationwide usage system of the NAA facility in Hanaro in many different and important areas of biological area can be initiated with the results. The output of the project can support public heath, environment, and medical research area. The results can be applied for the process of micronutrients enhanced health food production and for the health safety and health status enhancement with the additional necessary data expansion and the development of various evaluation technique. 19 refs., 7 figs., 23 tabs. (Author)

  7. 40 CFR 80.581 - What are the batch testing and sample retention requirements for motor vehicle diesel fuel, NRLM...

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 16 2010-07-01 2010-07-01 false What are the batch testing and sample...; and ECA Marine Fuel Sampling and Testing § 80.581 What are the batch testing and sample retention... refiner and importer shall collect a representative sample from each batch of motor vehicle or NRLM...

  8. Determination of rare earth and other elements in standard biological samples by ICP-MS and activation analysis

    International Nuclear Information System (INIS)

    Various rare earth elements (REEs) in standard samples supplied by the IAEA namely mussel (IAEA-142) and lichen (IAEA-336) were examined by ICP-MS and INAA. For ICP-MS, 200 mg each of the samples were dissolved in conc. nitric acid using a microwave sample-preparation system. After repeated concentration-dilution procedures (final volume; 10-20 ml), 1 ml of the sample was supplied for assay. La, Ce, Pr, Nd, Sm, Eu, Gd, Tb, Dy, Ho, Er, Tm and Yb could be detected in the order of magnitude of 10-3 ng/g. Activation analysis carried out using 300 mg of the sample powders failed to detect REEs except La, Ce, Sm and Eu because of a strong interference due mainly to 24Na and 32P induced in the samples by irradiation. The REE patterns (NASC-normalized) obtained for both the organisms are of the same in their shapes except for all the values for sea animal mussel which are somewhat higher than those for land plant lichen. However, we found a large difference in the other elements contents between the two organisms. For example, Na, Cl, Mg, K, and Ca contents in mussel are about 26, 7, 4.5, 3.5, and 2 times, those in lichen. As the concentrations in the sea water for these elements is from 102 (K and Ca) to 103 (Na, Cl and Mg) order of magnitude higher than in the land water, the result seems reasonable to assume that the higher the concentration of the element around the organisms the higher its content in the organisms. (author)

  9. Method Performance of Total Mercury (Hg) Testing in the Biological Samples by Using Cold Vapour Atomic Absorption Spectrophotometer (CV-AAS)

    International Nuclear Information System (INIS)

    Method performance (validation) of total mercury (Hg) testing in the biological samples by using cold vapour atomic absorption spectrophotometer (CV-AAS) has been done. The objective of this research is to know the method performance of CV-AAS as one of points for the accreditation testing of laboratory according IS0/IEC 17025-2005. The method performance covering limit of detection (LOD), accuracy, precision and bias. As a standard material used SRM Oyster Tissue 15660 from Winopal Forshung Germany, whereas the biological samples were human hair. In principle of mercury testing for solid samples using CV-AAS is dissolving this sample and standard with 10 mL HNO3 supra pure into a closed quartz tube and heating at 150 °C for 4 hours. The concentration of mercury in each samples was determined at the condition of operation were stirring time (T1) 70 seconds, delay time (T2) 15 seconds, heating time (T3) 13 seconds and cooling time (T4) of 25 seconds. Mercury ion in samples are reduced with SnCl2 10 % in H2SO4 20 %, and then the vapour of mercury from reduction is passed in NaOH 20 % solution and aquatridest. The result of method performance were: limit of detection (LOD) = 0.085 ng, accuracy 99.70 %, precision (RSD) = 1.64 % and bias = 0.30 %. From the validation result showed that the content of mercury total was in the range of certified values. The total mercury content (Hg) in human hair were varied from 406.93 - 699.07 ppb. (author)

  10. MOUSE SKIN TUMOR INITIATION-PROMOTION AND COMPLETE CARCINOGENESIS BIOASSAYS: MECHANISMS AND BIOLOGICAL ACTIVITIES OF EMISSION SAMPLES

    Science.gov (United States)

    Extracts of soots obtained from various sources were applied to the skin of mice in an effort to identify carcinogens in these mixtures and to link these materials to the etiology of human cancer. Samples of coal chimney soot, coke oven materials, industrial carbon black, oil sha...

  11. Fast quantification of α-lipoic acid in biological samples and dietary supplements using batch injection analysis with amperometric detection.

    Science.gov (United States)

    Santos Pereira, Laise Nayra Dos; da Silva, Iranaldo Santos; Araújo, Thaylan Pinheiro; Tanaka, Auro Atsushi; Angnes, Lúcio

    2016-07-01

    Batch injection analysis (BIA) with amperometric detection, using a pyrolytic graphite electrode modified with cobalt phthalocyanine (PG/CoPc), was employed for determination of α-lipoic acid (ALA) in pharmaceutical product and in synthetic urine samples. The proposed BIA method is based on the application of a potential of +0.9V vs. Ag/AgCl, KCl sat, enabling quantification of ALA over a concentration range from 1.3×10(-6) to 1.0×10(-4)molL(-1), with a detection limit of 1.5×10(-8)molL(-1). A sampling rate of 180 injections per hour was attained and measurements of the reproducibility of successive injections (100µmolL(-1) ALA on the same electrode) showed a RSD of 2.11% for 40 successive injections. The new sensor was utilised for ALA quantification in a dietary pharmaceutical supplement and in synthetic urine and the results obtained for both samples were compared with parallel analysis using high performance liquid chromatography (HPLC), the method recommended by the United States Pharmacopeia. The results obtained were similar (at a 95% confidence level) and in the case of the synthetic urine sample (prepared with a known amount of ALA) the recovery was situated between 98.0% and 102.6%. PMID:27154671

  12. Towards tender X-rays with Zernike phase-contrast imaging of biological samples at 50 nm resolution.

    Science.gov (United States)

    Vartiainen, Ismo; Warmer, Martin; Goeries, Dennis; Herker, Eva; Reimer, Rudolph; David, Christian; Meents, Alke

    2014-07-01

    X-ray microscopy is a commonly used method especially in material science application, where the large penetration depth of X-rays is necessary for three-dimensional structural studies of thick specimens with high-Z elements. In this paper it is shown that full-field X-ray microscopy at 6.2 keV can be utilized for imaging of biological specimens with high resolution. A full-field Zernike phase-contrast microscope based on diffractive optics is used to study lipid droplet formation in hepatoma cells. It is shown that the contrast of the images is comparable with that of electron microscopy, and even better contrast at tender X-ray energies between 2.5 keV and 4 keV is expected. PMID:24971976

  13. Critical comparison of radiometric and mass spectrometric methods for the determination of radionuclides in environmental, biological and nuclear waste samples.

    Science.gov (United States)

    Hou, Xiaolin; Roos, Per

    2008-02-11

    The radiometric methods, alpha (alpha)-, beta (beta)-, gamma (gamma)-spectrometry, and mass spectrometric methods, inductively coupled plasma mass spectrometry, accelerator mass spectrometry, thermal ionization mass spectrometry, resonance ionization mass spectrometry, secondary ion mass spectrometry, and glow discharge mass spectrometry are reviewed for the determination of radionuclides. These methods are critically compared for the determination of long-lived radionuclides important for radiation protection, decommissioning of nuclear facilities, repository of nuclear waste, tracer application in the environmental and biological researches, these radionuclides include (3)H, (14)C, (36)Cl, (41)Ca, (59,63)Ni, (89,90)Sr, (99)Tc, (129)I, (135,137)Cs, (210)Pb, (226,228)Ra, (237)Np, (241)Am, and isotopes of thorium, uranium and plutonium. The application of on-line methods (flow injection/sequential injection) for separation of radionuclides and automated determination of radionuclides is also discussed. PMID:18215644

  14. Direct online HPLC-CV-AFS method for traces of methylmercury without derivatisation: a matrix-independent method for urine, sediment and biological tissue samples.

    Science.gov (United States)

    Brombach, Christoph-Cornelius; Gajdosechova, Zuzana; Chen, Bin; Brownlow, Andrew; Corns, Warren T; Feldmann, Jörg; Krupp, Eva M

    2015-01-01

    Mercury (Hg) is a global pollutant which occurs in different species, with methylmercury (MeHg) being the critical compound due to its neurotoxicity and bioaccumulation through the food chain. Methods for trace speciation of MeHg are therefore needed for a vast range of sample matrices, such as biological tissues, fluids, soils or sediments. We have previously developed an ultra-trace speciation method for methylmercury in water, based on a preconcentration HPLC cold vapour atomic fluorescence spectrometry (HPLC-CV-AFS) method. The focus of this work is mercury speciation in a variety of sample matrices to assess the versatility of the method. Certified reference materials were used where possible, and samples were spiked where reference materials were not available, e.g. human urine. Solid samples were submitted for commonly used digestion or extraction processes to obtain a liquid sample for injection into the analytical system. For MeHg in sediment samples, an extraction procedure was adapted to accommodate MeHg separation from high amounts of Hg(2+) to avoid an overload of the column. The recovery for MeHg determination was found to be in the range of 88-104% in fish reference materials (DOLT-2, DOLT-4, DORM-3), lobster (TORT-2), seaweed (IAEA-140/TM), sediments (ERM(®)-CC580) and spiked urine and has been proven to be robust, reliable, virtually matrix-independent and relatively cost-effective. Applications in the ultra-trace concentration range are possible using the preconcentration up to 200 mL, while for higher MeHg-containing samples, lower volumes can be applied. A comparison was carried out between species-specific isotope dilution gas chromatography inductively coupled plasma mass spectrometry (SSID-GC-ICP-MS) as the gold standard and HPLC-CV-AFS for biological tissues (liver, kidney and muscle of pilot whales), showing a slope of 1.008 and R (2) = 0.97, which indicates that the HPLC-CV-AFS method achieves well-correlated results for MeHg in

  15. Application of direct solid sample analysis for the determination of chlorine in biological materials using electrothermal vaporization inductively coupled plasma mass spectrometry

    International Nuclear Information System (INIS)

    This work describes a methodology developed to carry out Cl determination in biological materials using electrothermal vaporization inductively coupled plasma mass spectrometry and direct solid sample analysis. The solid samples were directly weighed into graphite ‘cups’ and inserted into the graphite furnace. The RF power and the carrier gas flow rate were optimized at 1300 W and 0.7 L min−1, respectively. Calibration could be carried out using aqueous standard solutions with pre-dried modifiers (Pd + Nd or Pd + Ca) or using solid certified reference materials with the same pre-dried modifiers or without the use of modifiers. The limit of quantification was determined as 5 μg g−1 under optimized conditions and the Cl concentration was determined in five certified reference materials with certified concentrations for Cl, in addition to three certified reference materials, for which certified values for Cl were unavailable; in the latter case, the results were compared with those obtained using high-resolution continuum source molecular absorption spectrometry. Good agreement at a 95% statistical confidence level was achieved between determined and certified or reference values. - Highlights: • Direct determination of chlorine in solid biological materials is described for the first time using ICP-MS. • Calibration against aqueous standards is feasible. • The method is accurate and sensitive, regardless of the composition of the solid sample

  16. Pitfalls in the analysis of the physiological antioxidant glutathione (GSH) and its disulfide (GSSG) in biological samples: An elephant in the room.

    Science.gov (United States)

    Giustarini, Daniela; Tsikas, Dimitrios; Colombo, Graziano; Milzani, Aldo; Dalle-Donne, Isabella; Fanti, Paolo; Rossi, Ranieri

    2016-04-15

    Glutathione (GSH) is the most abundant low-molecular-mass thiol within cells and one of the major antioxidant compounds in body fluids. Under pro-oxidant conditions, two GSH molecules donate one electron each and are converted into glutathione disulfide (GSSG). The GSH/GSSG molar ratio is considered a powerful index of oxidative stress and disease risk. Despite high interest in GSH/GSSG titration as measures of thiol redox balance, no broad agreement has yet been reached as to the best pre-analytical and analytical methods for the quantitation of these molecules in biological samples. Consequently, measured concentrations of GSH and GSSG and calculated GSH/GSSG molar ratios vary widely among laboratories. Here, we describe in detail the main analytical and pre-analytical problems related to the artificial oxidation of the sulfhydryl (SH) group of GSH that occur during sample manipulation. We underline how this aspect has been neglected for long time after its first description more than fifty years ago. Finally, selected reliable procedures and methods to measure GSH and GSSG in biological samples are discussed. PMID:26905452

  17. Application of direct solid sample analysis for the determination of chlorine in biological materials using electrothermal vaporization inductively coupled plasma mass spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Santos de Gois, Jefferson; Pereira, Éderson R. [Departamento de Química, Universidade Federal de Santa Catarina, 88040-970 Florianópolis, SC (Brazil); Welz, Bernhard [Departamento de Química, Universidade Federal de Santa Catarina, 88040-970 Florianópolis, SC (Brazil); INCT de Energia e Ambiente do CNPq (Brazil); Borges, Daniel L.G., E-mail: daniel.borges@ufsc.br [Departamento de Química, Universidade Federal de Santa Catarina, 88040-970 Florianópolis, SC (Brazil); INCT de Energia e Ambiente do CNPq (Brazil)

    2015-03-01

    This work describes a methodology developed to carry out Cl determination in biological materials using electrothermal vaporization inductively coupled plasma mass spectrometry and direct solid sample analysis. The solid samples were directly weighed into graphite ‘cups’ and inserted into the graphite furnace. The RF power and the carrier gas flow rate were optimized at 1300 W and 0.7 L min{sup −1}, respectively. Calibration could be carried out using aqueous standard solutions with pre-dried modifiers (Pd + Nd or Pd + Ca) or using solid certified reference materials with the same pre-dried modifiers or without the use of modifiers. The limit of quantification was determined as 5 μg g{sup −1} under optimized conditions and the Cl concentration was determined in five certified reference materials with certified concentrations for Cl, in addition to three certified reference materials, for which certified values for Cl were unavailable; in the latter case, the results were compared with those obtained using high-resolution continuum source molecular absorption spectrometry. Good agreement at a 95% statistical confidence level was achieved between determined and certified or reference values. - Highlights: • Direct determination of chlorine in solid biological materials is described for the first time using ICP-MS. • Calibration against aqueous standards is feasible. • The method is accurate and sensitive, regardless of the composition of the solid sample.

  18. Quantification of chlorine in zirconium oxide and biological samples by instrumental NAA utilizing PCF of Dhruva reactor

    International Nuclear Information System (INIS)

    Recently studies on chlorine contents in various samples are being pursued due to its corrosive nature. Chlorine present at trace level in various finished products as well as powder is used as a raw material for production of different types of zircaloys used as structural materials in nuclear technology. As a part of quality assurance program, it is necessary to quantify chlorine accurately with suitable and simple technique. In the present work we have applied instrumental neutron activation analysis (INAA) utilizing its short-lived activation product (38Cl, 37 min, 1642 and 2168 keV) for its estimation. Pneumatic Carrier Facility (PCF) of Dhruva reactor, BARC was used sample irradiation of zirconium oxide dry powder, synthetic wax and IAEA RMs 1515 (Apple leaves) and Lichen 336. (author)

  19. Mouse skin tumor initiation-promotion and complete carcinogenesis bioassays: mechanisms and biological activities of emission samples.

    OpenAIRE

    Nesnow, S; Triplett, L L; Slaga, T J

    1983-01-01

    Extracts of soots obtained from various sources were applied to the skin of mice in an effort to identify carcinogens in these mixtures and to link these materials to the etiology of human cancer. Samples of coal chimney soot, coke oven materials, industrial carbon black, oil shale soot, and gasoline vehicle exhaust materials have been examined by this method. The studies reported here have been constructed to compare the carcinogenic and tumorigenic potency of extracts from various particula...

  20. Biological Sampling and Analysis in Sinclair and Dyes Inlets, Washington: Chemical Analyses for 2007 Puget Sound Biota Study

    Energy Technology Data Exchange (ETDEWEB)

    Brandenberger, Jill M.; Suslick, Carolynn R.; Johnston, Robert K.

    2008-10-09

    Evaluating spatial and temporal trends in contaminant residues in Puget Sound fish and macroinvertebrates are the objectives of the Puget Sound Ambient Monitoring Program (PSAMP). In a cooperative effort between the ENVironmental inVESTment group (ENVVEST) and Washington State Department of Fish and Wildlife, additional biota samples were collected during the 2007 PSAMP biota survey and analyzed for chemical residues and stable isotopes of carbon (δ13C) and nitrogen (δ15N). Approximately three specimens of each species collected from Sinclair Inlet, Georgia Basin, and reference locations in Puget Sound were selected for whole body chemical analysis. The muscle tissue of specimens selected for chemical analyses were also analyzed for δ13C and δ15N to provide information on relative trophic level and food sources. This data report summarizes the chemical residues for the 2007 PSAMP fish and macro-invertebrate samples. In addition, six Spiny Dogfish (Squalus acanthias) samples were necropsied to evaluate chemical residue of various parts of the fish (digestive tract, liver, embryo, muscle tissue), as well as, a weight proportional whole body composite (WBWC). Whole organisms were homogenized and analyzed for silver, arsenic, cadmium, chromium, copper, nickel, lead, zinc, mercury, 19 polychlorinated biphenyl (PCB) congeners, PCB homologues, percent moisture, percent lipids, δ13C, and δ15N.

  1. A Simple Spectrophotometric Method for the Trace Determination of Zinc in Some Real, Environmental, Biological, Pharmaceutical, Milk and Soil Samples Using 5,7- Dibromo-8-hydroxyquinoline

    International Nuclear Information System (INIS)

    A very simple, ultra-sensitive and highly selective non-extractive spectrophotometric method for the determination of trace amount of zinc using 5,7-dibromo-8-hydroxyquinoline (DBHQ) has been developed. DBHQ reacts in a slightly acidic solution (0.000001-0.000007 M H/sub 2/SO/sub 4/) with zinc to give a pale-yellow chelate, which has an absorption maximum at 391 nm. The reaction is instantaneous and absorbance remains stable for over 24 hrs. The average molar absorption co-efficient and Sandell's sensitivity were found to be 1.62 x 10/sup 5/ L mol/sup -1/ cm/sup -1/ and 10 ng cm/sup -2/ of Zn, respectively. Linear calibration graphs were obtained for 0.02-4 mg L/sup -1/ of Zn having detection limit of 5 mu g L/sup -1/ and RSD 0 - 2%. The stoichiometric composition of the chelate is 1:2 (Zn : DBHQ). A large excess of over 50 cations, anions and some common complexing agents (such as chloride, azide, tartrate, EDTA, oxalate, SCN-etc) do not interfere in the determination. The method was successfully used in the determination of zinc in several Standard Reference Materials (alloys and steels) as well as in some environmental waters (potable and polluted), biological samples (human blood and urine), soil samples, milk samples, pharmaceutical samples and complex synthetic mixtures.The results of the proposed method for biological samples were comparable with AAS and were found to be in excellent agreement. The method has high precision and accuracy (s = +- 0.01 for 0.5 mg L/sup -1/). (author)

  2. A Simple Spectrophotometric Method for the Trace Determination of Zinc in Some Real, Environmental, Biological, Pharmaceutical, Milk and Soil Samples Using 5,7- Dibromo-8-hydroxyquinoline

    Directory of Open Access Journals (Sweden)

    M. Jamaluddin Ahmed

    2013-06-01

    Full Text Available A very simple, ultra-sensitive and highly selective non-extractive spectrophotometric method for the determination of trace amount of zinc using 5,7-dibromo-8-hydroxyquinoline (DBHQ has been developed. DBHQ reacts in a slightly acidic solution (0.000001-0.000007 M H2S04 with zinc to give a pale-yellow chelate, which has an absorption maximum at 391 nm. The reaction is instantaneous and absorbance remains stable for over 24 hrs. The average molar absorption co-efficient and Sandell's sensitivity were found to be 1.62 x 105 L mol -1 cm -1 and 10 ng cm-2 of Zn, respectively. Linear calibration graphs were obtained for 0.02-4 mg L-1 of Zn having detection limit of 5 µg L-1 and RSD 0 - 2%. The stoichiometric composition of the chelate is 1:2 (Zn : DBHQ. A large excess of over 50 cations, anions and some common complexing agents (such as chloride, azide, tartrate, EDTA, oxalate, SCN- etc do not interfere in the determination. The method was successfully used in the determination of zinc in several Standard Reference Materials (alloys and steels as well as in some environmental waters (potable and polluted, biological samples (human blood and urine, soil samples, milk samples, pharmaceutical samples and complex synthetic mixtures.The results of the proposed method for biological samples were comparable with AAS and were found to be in excellent agreement.The method has high precision and accuracy (s = ± 0.01 for 0.5 mg L-1.

  3. Radiotoxicological analyses of 239+240Pu and 241Am in biological samples by anion-exchange and extraction chromatography: a preliminary study for internal contamination evaluations

    International Nuclear Information System (INIS)

    Many biological samples (urines and faeces) have been analysed by means of chromatographic extraction columns, utilising two different resins (AG 1-X2 resin chloride and T.R.U.), in order to detect the possible internal contamination of 239+240Pu and 241Am, for some workers of a reprocessing nuclear plant in the decommissioning phase. The results obtained show on one hand the great suitability of the first resin for the determination of plutonium, and on the other the great selectivity of the second one for the determination of americium

  4. Report of the Planning Group on Commercial Catches, Discards and Biological Sampling (PGCCDBS), 17-21 February 2014. Horta (Azores), Portugal

    OpenAIRE

    ICES

    2014-01-01

    The Planning Group on Commercial Catches, Discards and Biological Sampling [PGCCDBS] (Co-Chairs: Mike Armstrong, UK, and Gráinne Ní Chonchúir, Ireland) met in Horta, the Azores, 17th February – 21st February 2014. The PGCCDBS was established in 2002 in response to the EC-ICES Memorandum of Understanding (MoU) requesting ICES to provide support for the EU Data Collection Framework (DCF). It implements the ICES Quality Assurance Framework to ensure that data sets and parameters supporting asses...

  5. Sampling Size Required for Determining Soil Carbon and Nitrogen Properties at Early Establishment of Second Rotation Hoop Pine Plantations in Subtropical Australia

    Institute of Scientific and Technical Information of China (English)

    2007-01-01

    Investigations into forest soils face the problem of the high level of spatial variability that is an inherent property of all forest soils. In order to investigate the effect of changes in residue management practices on soil properties in hoop pine (Araucaria cunninghamii Aiton ex A. Cunn.) plantations of subtropical Australia it was important to understand the intensity of sampling effort required to overcome the spatial variability induced by those changes. Harvest residues were formed into windrows to prevent nitrogen (N) losses through volatilisation and erosion that had previously occurred as a result of pile and burn operations. We selected second rotation (2R) hoop pine sites where the windrows (10-15 m apart) had been formed 1, 2 and 3 years prior to sampling in order to examine the spatial variability in soil carbon (C)and N and in potential mineralisable N (PMN) in the areas beneath and between (inter-) the windrows. We examined the implications of soil variability on the number of samples required to detect differences in means for specific soil properties,at different ages and at specified levels of accuracy. Sample size needed to accurately reflect differences between means was not affected by the position where the samples were taken relative to the windrows but differed according to the parameter to be sampled. The relative soil sampling size required for detecting differences between means of a soil property in the inter-windrow and beneath-windrow positions was highly dependent on the soil property assessed and the acceptable relative sampling error. An alternative strategy for soil sampling should be considered, if the estimated sample size exceeds 50 replications. The possible solution to this problem is collection of composite soil samples allowing a substantial reduction in the number of samples required for chemical analysis without loss in the precision of the mean estimates for a particular soil property.

  6. Determination of androgens and progestogens in environmental and biological samples using fabric phase sorptive extraction coupled to ultra-high performance liquid chromatography tandem mass spectrometry.

    Science.gov (United States)

    Guedes-Alonso, Rayco; Ciofi, Lorenzo; Sosa-Ferrera, Zoraida; Santana-Rodríguez, José Juan; Bubba, Massimo Del; Kabir, Abuzar; Furton, Kenneth G

    2016-03-11

    Androgens and progestogens are two important groups of endocrine disrupting compounds (EDCs) which are implicated to produce severe detrimental impact over aquatic biota, even at very low concentrations of ngL(-1). For this reason, one of the major challenges to analytical chemists is the development of sensitive and selective extraction processes which allow the rapid and green determination of these emerging pollutants at low concentrations in environmental samples. Fabric phase sorptive extraction is a new, highly sensitive, efficient and solvent minimized technique which combine the advantages of sol-gel derived microextraction sorbents and the rich surface chemistry of cellulose fabric substrate. This process has several advantages such as minimum usage of organic solvents, short extraction times, small sample volumes and high analyte preconcentration factors. In this study, an extraction method based on sorptive fabric phase coupled to ultra-high-performance liquid chromatography tandem mass spectrometry detection (FPSE-UHPLC-MS/MS) has been developed for the determination of four progestogens and six androgens in environmental and biological samples. All the parameters involved in the extraction, such as sample volume, extraction and desorption times, desorption solvent volume and sample pH values have been optimized. The developed method provides satisfactory limits of detection (between 1.7 and 264ngL(-1)), good recoveries and low relative standard deviations (below 10% in tap and osmosis water and below 20% in wastewater and urine). Subsequently, the method was used to analyse tap water, wastewater treated with different processing technologies and urine samples. The concentrations of the detected hormones ranged from 28.3 to 227.3 ngL(-1) in water samples and from 1.1 to 3.7μgL(-1) in urine samples. PMID:26858117

  7. Application of the brittle fracture technique (BFT) to homogenise biological samples and some observations regarding the distribution behaviour of the trace elements at different concentration levels in a biological matrix

    International Nuclear Information System (INIS)

    NAA was used to analyse K, P, Cl, Na, Fe, Zn, Rb, Mn, Se, Co, and Ag in bovine liver, before and after homogenization, using brittle fracture technique (BFT). The liver specimen analysed in this experiment did not present any extreme variation problem with respect to the trace element distribution profile in the liver matrix. Elaborate sample-handling and the possible influence of the interfering components such as resudial blood, blood vessels and fat on the concentration profile of the above mentioned elements are discussed. In another experiments using 60Co, 134Cs, 141Ce and 198Au radiotracers, the physical distribution of the added tracers following the process of biological matrix disintegration, for homogenization purposes was studied at 1 mg to 10 pg concentration levels. The results indicate that BFT is an efficient, clean and practical tool that meets the homogenization problems because of its suitability to practically all types of biomedical samples. (T.G.)

  8. Simultaneous multi-species determination of trimethyllead, monomethylmercury and three butyltin compounds by species-specific isotope dilution GC-ICP-MS in biological samples

    Energy Technology Data Exchange (ETDEWEB)

    Poperechna, Nataliya; Heumann, Klaus G. [Johannes Gutenberg-University Mainz (Germany). Institute of Inorganic Chemistry and Analytical Chemistry

    2005-09-01

    An accurate and sensitive multi-species species-specific isotope dilution GC-ICP-MS method was developed for the simultaneous determination of trimethyllead (Me{sub 3}Pb{sup +}), monomethylmercury (MeHg{sup +}) and the three butyltin species Bu{sub 3}Sn{sup +}, Bu{sub 2}Sn{sup 2+}, and BuSn{sup 3+} in biological samples. The method was validated by three biological reference materials (CRM 477, mussel tissue certified for butyltins; CRM 463, tuna fish certified for MeHg{sup +}; DORM 2, dogfish muscle certified for MeHg{sup +}). Under certain conditions, and with minor modifications of the sample pretreatment procedure, this method could also be transferred to environmental samples such as sediments, as demonstrated by analyzing sediment reference material BCR 646 (freshwater sediment, certified for butyltins). The detection limits of the multi-species GC-ICP-IDMS method for biological samples were 1.4 ng g{sup -1} for MeHg{sup +}, 0.06 ng g{sup -1} for Me{sub 3}Pb{sup +}, 0.3 ng g{sup -1} for BuSn{sup 3+} and Bu{sub 3}Sn{sup +}, and 1.2 ng g{sup -1} for Bu{sub 2}Sn{sup 2+}. Because of the high relevance of these heavy metal alkyl species to the quality assurance of seafood, the method was also applied to corresponding samples purchased from a supermarket. The methylated lead fraction in these samples, correlated to total lead, varied over a broad range (from 0.01% to 7.6%). On the other hand, the MeHg{sup +} fraction was much higher, normally in the range of 80-100%. Considering that we may expect tighter legislative limitations on MeHg{sup +} levels in seafood in the future, we found the highest methylmercury contents (up to 10.6 {mu}g g{sup -1}) in two shark samples, an animal which is at the end of the marine food chain, whereas MeHg{sup +} contents of less than 0.2 {mu}g g{sup -1} were found in most other seafood samples; these results correlate with the idea that MeHg{sup +} is usually of biological origin in the marine environment. The concentration of

  9. A rapid spectrophotometric method for the determination of mercury in environmental, biological, soil and plant samples using diphenylthiocarbazone

    OpenAIRE

    AHMED, M. Jamaluddin; Alam, Md Shah

    2003-01-01

    A simple, sensitive and highly selective direct spectrophotometric method for the determination of trace levels of mercury(II) in various samples is described. Diphenylthiocarbazone (dithizone) reacts in slightly acidic 50% aqueous 1,4-dioxane media (0.18–1.80 M sulphuric acid) with mercury(II) to give an orange chelate which has an absorption maximum at 488 nm. The average molar absorption co-efficient and Sandell's sensitivity were found to be 2.5×104l mol−1 cm−1 and 0.015 μg of Hg(II) cm−2...

  10. A comparative study of phosphopeptide-selective techniques for a sub-proteome of a complex biological sample.

    Science.gov (United States)

    Källsten, Malin; Bergquist, Jonas; Zhao, Hongxing; Konzer, Anne; Lind, Sara Bergström

    2016-03-01

    Phosphorylation of proteins is important for controlling cellular signaling and cell cycle regulatory events. The process is reversible and phosphoproteins normally constitute a minor part of the global proteome in a cell. Thus, sample preparation techniques tailored for phosphoproteome studies are continuously invented and evaluated. This paper aims at evaluating the performances of the most popular techniques for phospho-enrichments in sub-proteome analysis, such as viral proteomes expressed in human cells during infection. A two-species sample of Adenovirus type 2 infected human cells was used, and in-solution digestion, strong cation exchange (SCX), and electrostatic repulsion hydrophilic interaction chromatography (ERLIC) fractionation, and subsequent enrichment by TiO2, were compared with SDS-PAGE fractionation and in-gel digestion. Evaluation was focused on phosphopeptide detection in the sub-proteome. The results showed that the SCX+TiO2 or ERLIC+TiO2 combinations had the highest enrichment efficiencies, but SDS-PAGE fractionation and in-gel digestion resulted in the highest number of identified proteins and phosphopeptides. Furthermore, the study demonstrates the usefulness of applying as many orthogonal techniques as possible in deep phosphoproteome analysis, since the overlap between approaches was low. PMID:26886742

  11. Development of a methodology for low-energy X-ray absorption correction in biological samples using radiation scattering techniques

    International Nuclear Information System (INIS)

    Non-destructive techniques with X-ray, such as tomography, radiography and X-ray fluorescence are sensitive to the attenuation coefficient and have a large field of applications in medical as well as industrial area. In the case of X-ray fluorescence analysis the knowledge of photon X-ray attenuation coefficients provides important information to obtain the elemental concentration. On the other hand, the mass attenuation coefficient values are determined by transmission methods. So, the use of X-ray scattering can be considered as an alternative to transmission methods. This work proposes a new method for obtain the X-ray absorption curve through superposition peak Rayleigh and Compton scattering of the lines La e Lβ of Tungsten (Tungsten L lines of an X-ray tube with W anode). The absorption curve was obtained using standard samples with effective atomic number in the range from 6 to 16. The method were applied in certified samples of bovine liver (NIST 1577B) , milk powder and V-10. The experimental measurements were obtained using the portable system EDXRF of the Nuclear Instrumentation Laboratory (LIN-COPPE/UFRJ) with Tungsten (W) anode. (author)

  12. Dithizone chloroform single drop microextraction system combined with electrothermal atomic absorption spectrometry using Ir as permanent modifier for the determination of Cd in water and biological samples

    Science.gov (United States)

    Fan, Zhefeng; Zhou, Wei

    2006-07-01

    A simple and sensitive method using dithizone-chloroform single drop microextraction has been developed for separation and preconcentration of trace Cd prior to its determination by electrothermal atomic absorption spectrometry with Ir as permanent modifier. Parameters, such as pyrolysis and atomization temperature, solvent type, pH, dithizone concentration, extraction time, organic drop volume, stirring rate and sample volume were investigated. Under the optimized conditions, a detection limit (3 σ) of 0.7 ng/l and enrichment factor of 65 were achieved. The relative standard deviation was 7.4% ( c = 0.2 μg/l, n = 5). The developed method has been applied to the determination of trace Cd in water samples and biological reference materials with satisfactory results.

  13. Dithizone-chloroform single drop microextraction system combined with electrothermal atomic absorption spectrometry using Ir as permanent modifier for the determination of Cd in water and biological samples

    Energy Technology Data Exchange (ETDEWEB)

    Fan Zhefeng [Department of Chemistry, Shanxi Normal University, Linfen 041004 (China)]. E-mail: zhefengfan@163.com; Zhou Wei [Department of Chemistry, Shanxi Normal University, Linfen 041004 (China)

    2006-07-15

    A simple and sensitive method using dithizone-chloroform single drop microextraction has been developed for separation and preconcentration of trace Cd prior to its determination by electrothermal atomic absorption spectrometry with Ir as permanent modifier. Parameters, such as pyrolysis and atomization temperature, solvent type, pH, dithizone concentration, extraction time, organic drop volume, stirring rate and sample volume were investigated. Under the optimized conditions, a detection limit (3{sigma}) of 0.7 ng/l and enrichment factor of 65 were achieved. The relative standard deviation was 7.4% (c = 0.2 {mu}g/l, n = 5). The developed method has been applied to the determination of trace Cd in water samples and biological reference materials with satisfactory results.

  14. Formation of ternary complexes with MgATP: effects on the detection of Mg2+ in biological samples by bidentate fluorescent sensors.

    Science.gov (United States)

    Schwartz, Sarina C; Pinto-Pacheco, Brismar; Pitteloud, Jean-Philippe; Buccella, Daniela

    2014-03-17

    Fluorescent indicators based on β-keto-acid bidentate coordination motifs display superior metal selectivity profiles compared to current o-aminophenol-N,N,O-triacetic acid (APTRA) based chelators for the study of biological magnesium. These low denticity chelators, however, may allow for the formation of ternary complexes with Mg(2+) and common ligands present in the cellular milieu. In this work, absorption, fluorescence, and NMR spectroscopy were employed to study the interaction of turn-on and ratiometric fluorescent indicators based on 4-oxo-4H-quinolizine-3-carboxylic acid with Mg(2+) and ATP, the most abundant chelator of biological magnesium, thus revealing the formation of ternary complexes under conditions relevant to fluorescence imaging. The formation of ternary species elicits comparable or greater optical changes than those attributed to the formation of binary complexes alone. Dissociation of the fluorescent indicators from both ternary and binary species have apparent equilibrium constants in the low millimolar range at pH 7 and 25 °C. These results suggest that these bidentate sensors are incapable of distinguishing between free Mg(2+) and MgATP based on ratio or intensity-based steady-state fluorescence measurements, thus posing challenges in the interpretation of results from fluorescence imaging of magnesium in nucleotide-rich biological samples. PMID:24593871

  15. Reproductive Requirements and Life Cycle of Iberorhyzobius rondensis (Coleoptera: Coccinellidae), Potential Biological Control Agent of Matsucoccus feytaudi (Hemiptera: Matsucoccidae).

    Science.gov (United States)

    Tavares, C; Jactel, H; van Halder, I; Branco, M

    2015-06-01

    Several pine bast scales (Hemiptera: Matsucoccidae) are important pests of pine trees in the Northern Hemisphere. Some species are invasive and cause significant economic and environmental impacts. Such is the case with Matsucoccus feytaudi Ducasse, an invasive pest of maritime pine forests in Southeastern France, Italy, and Corsica. The ladybird Iberorhyzobius rondensis (Eizaguirre) is a recently described species that is endemic to the Iberian Peninsula and is a potential candidate for the biological control of M. feytaudi. However, little is known of the biology of I. rondensis. As part of the risk assessment study for a classical biological control program, the phenology and reproductive mechanisms of the beetle were analyzed. I. rondensis is univoltine and is seasonally synchronized with the phenology of the prey M. feytaudi, which is also univoltine. An obligatory reproductive diapause of 5-6 mo and the need to feed on the eggs of the prey to begin oviposition emerged as the two primary mechanisms that assure life cycle synchronization of the ladybird with its prey. Female fecundity was also higher when the ladybirds were fed M. feytaudi eggs. Life cycle synchronization with M. feytaudi and reproduction triggered by consumption of prey eggs indicate that I. rondensis is a promising biological control agent of the pine bast scale. PMID:26313991

  16. Simultaneous quantitative profiling of 20 isoprostanoids from omega-3 and omega-6 polyunsaturated fatty acids by LC-MS/MS in various biological samples.

    Science.gov (United States)

    Dupuy, Aude; Le Faouder, Pauline; Vigor, Claire; Oger, Camille; Galano, Jean-Marie; Dray, Cédric; Lee, Jetty Chung-Yung; Valet, Philippe; Gladine, Cécile; Durand, Thierry; Bertrand-Michel, Justine

    2016-05-19

    Isoprostanoids are a group of non-enzymatic oxygenated metabolites of polyunsaturated fatty acids. It belongs to oxylipins group, which are important lipid mediators in biological processes, such as tissue repair, blood clotting, blood vessel permeability, inflammation and immunity regulation. Recently, isoprostanoids from eicosapentaenoic, docosahexaenoic, adrenic and α-linolenic namely F3-isoprostanes, F4-neuroprostanes, F2-dihomo-isoprostanes and F1-phytoprostanes, respectively have attracted attention because of their putative contribution to health. Since isoprostanoids are derived from different substrate of PUFAs and can have similar or opposing biological consequences, a total isoprostanoids profile is essential to understand the overall effect in the testing model. However, the concentration of most isoprostanoids range from picogram to nanogram, therefore a sensitive method to quantify 20 isoprostanoids simultaneously was formulated and measured by liquid chromatography-tandem mass spectrometry (LC-MS/MS). The lipid portion from various biological samples was extracted prior to LC-MS/MS evaluation. For all the isoprostanoids LOD and LOQ, and the method was validated on plasma samples for matrix effect, yield of extraction and reproducibility were determined. The methodology was further tested for the isoprostanoids profiles in brain and liver of LDLR(-/-) mice with and without docosahexaenoic acid (DHA) supplementation. Our analysis showed similar levels of total F2-isoprostanes and F4-neuroprostanes in the liver and brain of non-supplemented LDLR(-/-) mice. The distribution of different F2-isoprostane isomers varied between tissues but not for F4-neuroprostanes which were predominated by the 4(RS)-4-F4t-neuroprostane isomer. DHA supplementation to LDLR(-/-) mice concomitantly increased total F4-neuroprostanes levels compared to F2-isoprostanes but this effect was more pronounced in the liver than brain. PMID:27126789

  17. A solid liquid extraction and preconcentration method for the atomic absorption spectrometric determination of trace cobalt in various alloys and biological samples

    International Nuclear Information System (INIS)

    Cobalt is quantitatively retained as cobalt-2-nitroso-4-sulfonic acid (nitros-S)-tetradecyldimethylbenzylammonium (TDBA+) ion-pair complex on microcrystalline naphthalene in the pH range 6.2-9.0 from a large volume of its aqueous solution of various complex samples. After filtration, the solid mass consisting of cobalt complex and naphthalene is dissolved in 5 ml of dimethylformamide (DMF) and the metal is determined by flame atomic absorption spectrometry (FAAS). Cobalt complex can alternatively be quantitatively adsorbed on tetradecyldimethylbenzylammonium chloride-naphthalene adsorbent packed in a column and determined similarly. The calibration curve is linear over the concentration range 0.2-11.5 μg of cobalt in 5 ml of the final DMF solution. In this case, 0.2 μg of cobalt may be concentrated in a column from 250 ml of aqueous sample where its concentration is as low as 0.8 ng/ml. Eight replicate determinations of 3.0 μg of cobalt in the final DMF solution give a mean absorbance of 0.045 with a relative standard deviation of 1.8%. The sensitivity for 1% absorption is 59 ng/ml. The interference of a large number of anions and cations on the determination of cobalt has been studied and the optimum conditions developed utilized for its trace determination in various alloys and biological samples. The method may also be used for the determination of cobalt in some environmental samples

  18. 4D (x-y-z-t) imaging of thick biological samples by means of Two-Photon inverted Selective Plane Illumination Microscopy (2PE-iSPIM)

    Science.gov (United States)

    Lavagnino, Zeno; Sancataldo, Giuseppe; D’Amora, Marta; Follert, Philipp; de Pietri Tonelli, Davide; Diaspro, Alberto; Cella Zanacchi, Francesca

    2016-04-01

    In the last decade light sheet fluorescence microscopy techniques, such as selective plane illumination microscopy (SPIM), has become a well established method for developmental biology. However, conventional SPIM architectures hardly permit imaging of certain tissues since the common sample mounting procedure, based on gel embedding, could interfere with the sample morphology. In this work we propose an inverted selective plane microscopy system (iSPIM), based on non-linear excitation, suitable for 3D tissue imaging. First, the iSPIM architecture provides flexibility on the sample mounting, getting rid of the gel-based mounting typical of conventional SPIM, permitting 3D imaging of hippocampal slices from mouse brain. Moreover, all the advantages brought by two photon excitation (2PE) in terms of reduction of scattering effects and contrast improvement are exploited, demonstrating an improved image quality and contrast compared to single photon excitation. The system proposed represents an optimal platform for tissue imaging and it smooths the way to the applicability of light sheet microscopy to a wider range of samples including those that have to be mounted on non-transparent surfaces.

  19. Determination of U, Th and Nb by ICP-MS in biological samples from a group non-occupationally exposed persons

    International Nuclear Information System (INIS)

    In order to have a good intake assessment for workers, by in vitro bioassay, appropriate methods to determine trace concentrations in urine and feces samples are required. Since the concentration of the radionuclides in the excretion samples of the workers shall be compared to the ones in the excretion samples of the members of the public. The adoption of this procedure is need to evaluate the contribution of the intake through diet ingestion or inhalation of particles in high background radiation areas, which can result in an increasing of the concentration of radionuclides in urine and feces samples due to environmental exposure independent of the occupational exposure. In Brazil, the radionuclides from the uranium and thorium series can be found associated to the ores. In order to carry out an evaluation of the internal contamination in workers from mine industry, specially niobium mine, the optimization of the methodology of the urine and feces sample preparation for determination of U, Th e Nb content using ICP-MS (Inductively Coupled Plasma - Mass Spectrometer) was need. For the feces sample preparation, the sample ash (400 deg C) was the first step, followed by the addition of the nitric, hydrofluoric and perchloric suprapur acids in PTFE recipient covered. The residue was dissolved with 2% nitric acid. For the urine samples, 1-ml aliquot was diluted in 2% nitric acid. A total of 23 feces samples and 25 urine samples from a group of inhabitants of Rio de Janeiro city, including children and adults, were analyzed. The results will be used as reference values in studies of evaluation of intake due to occupational exposure in Brazil. (author)

  20. 40 CFR 80.583 - What alternative sampling and testing requirements apply to importers who transport motor vehicle...

    Science.gov (United States)

    2010-07-01

    ... applicable. (b) Quality assurance program. The importer must conduct a quality assurance program, as specified in this paragraph (b), for each truck or rail car loading terminal. (1) Quality assurance samples... an independent laboratory, and the terminal operator must not know in advance when samples are to...