WorldWideScience

Sample records for biological samples requirements

  1. Standard reporting requirements for biological samples in metabolomics experiments: Microbial and in vitro biology experiments

    NARCIS (Netherlands)

    Werf, M.J. van der; Takors, R.; Smedsgaard, J.; Nielsen, J.; Ferenci, T.; Portais, J.C.; Wittmann, C.; Hooks, M.; Tomassini, A.; Oldiges, M.; Fostel, J.; Sauer, U.

    2007-01-01

    With the increasing use of metabolomics as a means to study a large number of different biological research questions, there is a need for a minimal set of reporting standards that allow the scientific community to evaluate, understand, repeat, compare and re-investigate metabolomics studies. Here w

  2. High resolution x-ray microtomography of biological samples: Requirements and strategies for satisfying them

    Energy Technology Data Exchange (ETDEWEB)

    Loo, B.W. Jr. [Univ. of California, San Francisco, CA (United States)]|[Univ. of California, Davis, CA (United States)]|[Lawrence Berkeley National Lab., CA (United States); Rothman, S.S. [Univ. of California, San Francisco, CA (United States)]|[Lawrence Berkeley National Lab., CA (United States)

    1997-02-01

    High resolution x-ray microscopy has been made possible in recent years primarily by two new technologies: microfabricated diffractive lenses for soft x-rays with about 30-50 nm resolution, and high brightness synchrotron x-ray sources. X-ray microscopy occupies a special niche in the array of biological microscopic imaging methods. It extends the capabilities of existing techniques mainly in two areas: a previously unachievable combination of sub-visible resolution and multi-micrometer sample size, and new contrast mechanisms. Because of the soft x-ray wavelengths used in biological imaging (about 1-4 nm), XM is intermediate in resolution between visible light and electron microscopies. Similarly, the penetration depth of soft x-rays in biological materials is such that the ideal sample thickness for XM falls in the range of 0.25 - 10 {mu}m, between that of VLM and EM. XM is therefore valuable for imaging of intermediate level ultrastructure, requiring sub-visible resolutions, in intact cells and subcellular organelles, without artifacts produced by thin sectioning. Many of the contrast producing and sample preparation techniques developed for VLM and EM also work well with XM. These include, for example, molecule specific staining by antibodies with heavy metal or fluorescent labels attached, and sectioning of both frozen and plastic embedded tissue. However, there is also a contrast mechanism unique to XM that exists naturally because a number of elemental absorption edges lie in the wavelength range used. In particular, between the oxygen and carbon absorption edges (2.3 and 4.4 nm wavelength), organic molecules absorb photons much more strongly than does water, permitting element-specific imaging of cellular structure in aqueous media, with no artifically introduced contrast agents. For three-dimensional imaging applications requiring the capabilities of XM, an obvious extension of the technique would therefore be computerized x-ray microtomography (XMT).

  3. Biological sample collector

    Science.gov (United States)

    Murphy, Gloria A.

    2010-09-07

    A biological sample collector is adapted to a collect several biological samples in a plurality of filter wells. A biological sample collector may comprise a manifold plate for mounting a filter plate thereon, the filter plate having a plurality of filter wells therein; a hollow slider for engaging and positioning a tube that slides therethrough; and a slide case within which the hollow slider travels to allow the tube to be aligned with a selected filter well of the plurality of filter wells, wherein when the tube is aligned with the selected filter well, the tube is pushed through the hollow slider and into the selected filter well to sealingly engage the selected filter well and to allow the tube to deposit a biological sample onto a filter in the bottom of the selected filter well. The biological sample collector may be portable.

  4. Enhanced Biological Sampling Data

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — This is a database of a variety of biological, reproductive, and energetic data collected from fish on the continental shelf in the northwest Atlantic Ocean. Species...

  5. Biological Sampling Variability Study

    Energy Technology Data Exchange (ETDEWEB)

    Amidan, Brett G. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Hutchison, Janine R. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States)

    2016-11-08

    There are many sources of variability that exist in the sample collection and analysis process. This paper addresses many, but not all, sources of variability. The main focus of this paper was to better understand and estimate variability due to differences between samplers. Variability between days was also studied, as well as random variability within each sampler. Experiments were performed using multiple surface materials (ceramic and stainless steel), multiple contaminant concentrations (10 spores and 100 spores), and with and without the presence of interfering material. All testing was done with sponge sticks using 10-inch by 10-inch coupons. Bacillus atrophaeus was used as the BA surrogate. Spores were deposited using wet deposition. Grime was coated on the coupons which were planned to include the interfering material (Section 3.3). Samples were prepared and analyzed at PNNL using CDC protocol (Section 3.4) and then cultured and counted. Five samplers were trained so that samples were taken using the same protocol. Each sampler randomly sampled eight coupons each day, four coupons with 10 spores deposited and four coupons with 100 spores deposited. Each day consisted of one material being tested. The clean samples (no interfering materials) were run first, followed by the dirty samples (coated with interfering material). There was a significant difference in recovery efficiency between the coupons with 10 spores deposited (mean of 48.9%) and those with 100 spores deposited (mean of 59.8%). There was no general significant difference between the clean and dirty (containing interfering material) coupons or between the two surface materials; however, there was a significant interaction between concentration amount and presence of interfering material. The recovery efficiency was close to the same for coupons with 10 spores deposited, but for the coupons with 100 spores deposited, the recovery efficiency for the dirty samples was significantly larger (65

  6. Prediction uncertainty assessment of a systems biology model requires a sample of the full probability distribution of its parameters

    NARCIS (Netherlands)

    Mourik, van S.; Braak, ter C.J.F.; Stigter, J.D.; Molenaar, J.

    2014-01-01

    Multi-parameter models in systems biology are typically ‘sloppy’: some parameters or combinations of parameters may be hard to estimate from data, whereas others are not. One might expect that parameter uncertainty automatically leads to uncertain predictions, but this is not the case. We illustrate

  7. Atomic force microscopy of biological samples

    Energy Technology Data Exchange (ETDEWEB)

    Doktycz, Mitchel John [ORNL

    2010-01-01

    The ability to evaluate structural-functional relationships in real time has allowed scanning probe microscopy (SPM) to assume a prominent role in post genomic biological research. In this mini-review, we highlight the development of imaging and ancillary techniques that have allowed SPM to permeate many key areas of contemporary research. We begin by examining the invention of the scanning tunneling microscope (STM) by Binnig and Rohrer in 1982 and discuss how it served to team biologists with physicists to integrate high-resolution microscopy into biological science. We point to the problems of imaging nonconductive biological samples with the STM and relate how this led to the evolution of the atomic force microscope (AFM) developed by Binnig, Quate, and Gerber, in 1986. Commercialization in the late 1980s established SPM as a powerful research tool in the biological research community. Contact mode AFM imaging was soon complemented by the development of non-contact imaging modes. These non-contact modes eventually became the primary focus for further new applications including the development of fast scanning methods. The extreme sensitivity of the AFM cantilever was recognized and has been developed into applications for measuring forces required for indenting biological surfaces and breaking bonds between biomolecules. Further functional augmentation to the cantilever tip allowed development of new and emerging techniques including scanning ion-conductance microscopy (SICM), scanning electrochemical microscope (SECM), Kelvin force microscopy (KFM) and scanning near field ultrasonic holography (SNFUH).

  8. [The ethical implications of conserving biological samples].

    Science.gov (United States)

    Tazzite, A; Roky, R; Avard, D

    2009-09-01

    The conservation and use of biological samples become more and more frequent all around the world. Biobanks of human body substances (blood, urine, DNA, tissues, cells, etc.), and personal data associated with them are created. They have a double character as they are collections of both human biological samples and personal data. In some cases, the gametes, reproductive tissues, embryos, foetal tissue after abortion or even specimens of dead donors are collected and conserved. Although biobanks raise hopes in both the development of new therapies, new drugs and their integration into clinical medicine, they also point to concerns related to ethical questions such as: the principles of information, the consent of the persons concerned, the confidentiality about the personal data, and in some cases discrimination and stigmatisation. Other ethical aspects could raise gradually as research advance. Research being carried out on human sample requires informed free consent from the person who should be able to consent. The donor must be sufficiently informed about the process of research, the purpose, benefits and the risks involved in participating in this research. In the case of persons unable to give consent such minors or persons with mental disabilities, special measures are undertaken. Once the consent was given, the right of withdrawal has been consistently supported by the various declarations and regulations, but some oppose this right for a number of reasons particularly in the case of research on the samples without risk of physical exposure. In this case the notion of human body integrity is different than in research involving therapeutic or clinical intervention. In the case of withdrawal of consent, the samples should be destroyed, but the anonymous results arising from them and their analysis are not affected. What is the case for future uses? Should the researcher obtain again the consent from the donor for a secondary use of the samples? This is a

  9. Biological Environmental Sampling Technologies Assessment

    Science.gov (United States)

    2015-12-01

    Nano Intelligent Detection System (NIDS) ........................5 2.3 BBI Detection BWA Integrated Multiplex Assay and Sampling System (IMASS...the samples can be collected ft2 Informational only Not provided N/A N/A Info only GRAND TOTAL 920 5 2.2 ANP Technologies Nano Intelligent ...from all types of surfaces and absorb unknown liquids. The Aklus Shield system can also be used to sample debris, soil, or vegetation . For this

  10. Accelerator mass spectrometry of small biological samples.

    Science.gov (United States)

    Salehpour, Mehran; Forsgard, Niklas; Possnert, Göran

    2008-12-01

    Accelerator mass spectrometry (AMS) is an ultra-sensitive technique for isotopic ratio measurements. In the biomedical field, AMS can be used to measure femtomolar concentrations of labeled drugs in body fluids, with direct applications in early drug development such as Microdosing. Likewise, the regenerative properties of cells which are of fundamental significance in stem-cell research can be determined with an accuracy of a few years by AMS analysis of human DNA. However, AMS nominally requires about 1 mg of carbon per sample which is not always available when dealing with specific body substances such as localized, organ-specific DNA samples. Consequently, it is of analytical interest to develop methods for the routine analysis of small samples in the range of a few tens of microg. We have used a 5 MV Pelletron tandem accelerator to study small biological samples using AMS. Different methods are presented and compared. A (12)C-carrier sample preparation method is described which is potentially more sensitive and less susceptible to contamination than the standard procedures.

  11. Fluorine ion transmission through thin biological samples

    Institute of Scientific and Technical Information of China (English)

    XueJian-Ming; WangYu-Gang; 等

    1998-01-01

    F2+ beam with 3MeV is used to irradiate thin biological samples(onion inner suface membrane and kidney bean coat)in the transmission measurement ,its current density is 400-800nA/cm2,Results show that the onion samples can be broken up quickly under ion irradiating;as to kidney bean samples,about 60% of the implanted ions penetrate the samples,most of them lose part of their eneregy,fewer ions are found to be able to transmit through the sample without energy loss.SEM experiments are carried out to study sample's damage induced by the ions irradiation.

  12. Discovering biological progression underlying microarray samples.

    Directory of Open Access Journals (Sweden)

    Peng Qiu

    2011-04-01

    Full Text Available In biological systems that undergo processes such as differentiation, a clear concept of progression exists. We present a novel computational approach, called Sample Progression Discovery (SPD, to discover patterns of biological progression underlying microarray gene expression data. SPD assumes that individual samples of a microarray dataset are related by an unknown biological process (i.e., differentiation, development, cell cycle, disease progression, and that each sample represents one unknown point along the progression of that process. SPD aims to organize the samples in a manner that reveals the underlying progression and to simultaneously identify subsets of genes that are responsible for that progression. We demonstrate the performance of SPD on a variety of microarray datasets that were generated by sampling a biological process at different points along its progression, without providing SPD any information of the underlying process. When applied to a cell cycle time series microarray dataset, SPD was not provided any prior knowledge of samples' time order or of which genes are cell-cycle regulated, yet SPD recovered the correct time order and identified many genes that have been associated with the cell cycle. When applied to B-cell differentiation data, SPD recovered the correct order of stages of normal B-cell differentiation and the linkage between preB-ALL tumor cells with their cell origin preB. When applied to mouse embryonic stem cell differentiation data, SPD uncovered a landscape of ESC differentiation into various lineages and genes that represent both generic and lineage specific processes. When applied to a prostate cancer microarray dataset, SPD identified gene modules that reflect a progression consistent with disease stages. SPD may be best viewed as a novel tool for synthesizing biological hypotheses because it provides a likely biological progression underlying a microarray dataset and, perhaps more importantly, the

  13. 9 CFR 113.3 - Sampling of biological products.

    Science.gov (United States)

    2010-01-01

    ... nonviral Master Seeds requiring cell culture propagation. For Master Seeds isolated or passed in a cell... additional species. For Master Seeds grown in cell culture and intended for use in more than one species, an... 9 Animals and Animal Products 1 2010-01-01 2010-01-01 false Sampling of biological products....

  14. The application of ESEM to biological samples

    Energy Technology Data Exchange (ETDEWEB)

    McGregor, J E; Donald, A M, E-mail: jem60@cam.ac.u [Cavendish Laboratory, University of Cambridge, J. J. Thomson Avenue, Cambridge CB3 OHE (United Kingdom)

    2010-07-01

    The Environmental Scanning Electron Microscope (ESEM) differs from a conventional SEM in that a differential pumping system maintains a pressure of gas (typically H{sub 2}O) in the specimen chamber whilst the gun remains at high vacuum. Ionizing collisions between electrons and these gas molecules create positive ions which drift down onto the sample neutralising specimen charge. It is therefore possible to image insulating samples without the need for metallic coating. The presence of water vapour in the chamber also means that a high relative humidity can be maintained and samples can be imaged in a hydrated state without the need for dehydration and fixation. These features suggest that ESEM could be well suited to imaging biological samples undergoing natural biological processes. We present a proof of principle study on the closure of stomatal pores in Tradescantia andersonia leaf tissue. An imaging protocol is developed and the advantages and limitations of this technique are discussed. Images of Vicia fabaleaf tissue are also presented. Challenges include minimising beam damage and reconciling the need for an adequate physiological temperature and a low gas pressure favourable for imaging, with the thermodynamic constraints on achieving a high relative humidity.

  15. Measurement of NO in biological samples.

    Science.gov (United States)

    Csonka, C; Páli, T; Bencsik, P; Görbe, A; Ferdinandy, P; Csont, T

    2015-03-01

    Although the physiological regulatory function of the gasotransmitter NO (a diatomic free radical) was discovered decades ago, NO is still in the frontline research in biomedicine. NO has been implicated in a variety of physiological and pathological processes; therefore, pharmacological modulation of NO levels in various tissues may have significant therapeutic value. NO is generated by NOS in most of cell types and by non-enzymatic reactions. Measurement of NO is technically difficult due to its rapid chemical reactions with a wide range of molecules, such as, for example, free radicals, metals, thiols, etc. Therefore, there are still several contradictory findings on the role of NO in different biological processes. In this review, we briefly discuss the major techniques suitable for measurement of NO (electron paramagnetic resonance, electrochemistry, fluorometry) and its derivatives in biological samples (nitrite/nitrate, NOS, cGMP, nitrosothiols) and discuss the advantages and disadvantages of each method. We conclude that to obtain a meaningful insight into the role of NO and NO modulator compounds in physiological or pathological processes, concomitant assessment of NO synthesis, NO content, as well as molecular targets and reaction products of NO is recommended.

  16. Mars Sample Handling and Requirements Panel (MSHARP)

    Science.gov (United States)

    Carr, Michael H.; McCleese, Daniel J.; Bada, Jeffrey L.; Bogard, Donald D.; Clark, Benton C.; DeVincenzi, Donald; Drake, Michael J.; Nealson, Kenneth H.; Papike, James J.; Race, Margaret S.; Stahl, David

    1999-01-01

    In anticipation of the return of samples from Mars toward the end of the first decade of the next century, NASA's Office of Space Sciences chartered a panel to examine how Mars samples should be handled. The panel was to make recommendations in three areas: (1) sample collection and transport back to Earth; (2) certification of the samples as nonhazardous; and (3) sample receiving, curation, and distribution. This report summarizes the findings of that panel. The samples should be treated as hazardous until proven otherwise. They are to be sealed within a canister on Mars, and the canister is not to be opened until within a Biosafety Hazard Level 4 (BSL-4) containment facility here on Earth. This facility must also meet or exceed the cleanliness requirements of the Johnson Space Center (JSC) facility for curation of extraterrestrial materials. A containment facility meeting both these requirements does not yet exist. Hazard assessment and life detection experiments are to be done at the containment facility, while geochemical characterization is being performed on a sterilized subset of the samples released to the science community. When and if the samples are proven harmless, they are to be transferred to a curation facility, such as that at JSC.

  17. Fast x-ray fluorescence microtomography of hydrated biological samples.

    Directory of Open Access Journals (Sweden)

    Enzo Lombi

    Full Text Available Metals and metalloids play a key role in plant and other biological systems as some of them are essential to living organisms and all can be toxic at high concentrations. It is therefore important to understand how they are accumulated, complexed and transported within plants. In situ imaging of metal distribution at physiological relevant concentrations in highly hydrated biological systems is technically challenging. In the case of roots, this is mainly due to the possibility of artifacts arising during sample preparation such as cross sectioning. Synchrotron x-ray fluorescence microtomography has been used to obtain virtual cross sections of elemental distributions. However, traditionally this technique requires long data acquisition times. This has prohibited its application to highly hydrated biological samples which suffer both radiation damage and dehydration during extended analysis. However, recent advances in fast detectors coupled with powerful data acquisition approaches and suitable sample preparation methods can circumvent this problem. We demonstrate the heightened potential of this technique by imaging the distribution of nickel and zinc in hydrated plant roots. Although 3D tomography was still impeded by radiation damage, we successfully collected 2D tomograms of hydrated plant roots exposed to environmentally relevant metal concentrations for short periods of time. To our knowledge, this is the first published example of the possibilities offered by a new generation of fast fluorescence detectors to investigate metal and metalloid distribution in radiation-sensitive, biological samples.

  18. Biological and Environmental Research Network Requirements

    Energy Technology Data Exchange (ETDEWEB)

    Balaji, V. [Princeton Univ., NJ (United States). Earth Science Grid Federation (ESGF); Boden, Tom [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Cowley, Dave [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Dart, Eli [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States). ESNet; Dattoria, Vince [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States). ESNet; Desai, Narayan [Argonne National Lab. (ANL), Argonne, IL (United States); Egan, Rob [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Foster, Ian [Argonne National Lab. (ANL), Argonne, IL (United States); Goldstone, Robin [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Gregurick, Susan [U.S. Dept. of Energy, Washington, DC (United States). Biological Systems Science Division; Houghton, John [U.S. Dept. of Energy, Washington, DC (United States). Biological and Environmental Research (BER) Program; Izaurralde, Cesar [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Johnston, Bill [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States). ESNet; Joseph, Renu [U.S. Dept. of Energy, Washington, DC (United States). Climate and Environmental Sciences Division; Kleese-van Dam, Kerstin [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Lipton, Mary [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Monga, Inder [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States). ESNet; Pritchard, Matt [British Atmospheric Data Centre (BADC), Oxon (United Kingdom); Rotman, Lauren [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States). ESNet; Strand, Gary [National Center for Atmospheric Research (NCAR), Boulder, CO (United States); Stuart, Cory [Argonne National Lab. (ANL), Argonne, IL (United States); Tatusova, Tatiana [National Inst. of Health (NIH), Bethesda, MD (United States); Tierney, Brian [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States). ESNet; Thomas, Brian [Univ. of California, Berkeley, CA (United States); Williams, Dean N. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Zurawski, Jason [Internet2, Washington, DC (United States)

    2013-09-01

    The Energy Sciences Network (ESnet) is the primary provider of network connectivity for the U.S. Department of Energy (DOE) Office of Science (SC), the single largest supporter of basic research in the physical sciences in the United States. In support of SC programs, ESnet regularly updates and refreshes its understanding of the networking requirements of the instruments, facilities, scientists, and science programs that it serves. This focus has helped ESnet be a highly successful enabler of scientific discovery for over 25 years. In November 2012, ESnet and the Office of Biological and Environmental Research (BER) of the DOE SC organized a review to characterize the networking requirements of the programs funded by the BER program office. Several key findings resulted from the review. Among them: 1) The scale of data sets available to science collaborations continues to increase exponentially. This has broad impact, both on the network and on the computational and storage systems connected to the network. 2) Many science collaborations require assistance to cope with the systems and network engineering challenges inherent in managing the rapid growth in data scale. 3) Several science domains operate distributed facilities that rely on high-performance networking for success. Key examples illustrated in this report include the Earth System Grid Federation (ESGF) and the Systems Biology Knowledgebase (KBase). This report expands on these points, and addresses others as well. The report contains a findings section as well as the text of the case studies discussed at the review.

  19. [Biological material sampling for atomic absorption analysis].

    Science.gov (United States)

    Makarenko, N P; Ganebnykh, E V

    2007-01-01

    The optimum conditions have been chosen for mineralization of biological material for the atomic absorption determination of toxic metals, by using a [Russian characters: see text]-01 laboratory furnace (Gefest) upon exposure to high temperature, pressure, and microwave field. The completeness of dissection of biological material by microwave mineralization is shown under the optimal conditions.

  20. Estrogenic flavonoids: structural requirements for biological activity.

    Science.gov (United States)

    Miksicek, R J

    1995-01-01

    A systematic survey of polycyclic phenols has been performed to identify members of this chemical group with estrogenic activity. Twelve compounds were found to be able to stimulate the transcriptional activity of the human estrogen receptor expressed in cultured cells by transient transfection. These natural estrogens belong to several distinct, but chemically related classes including chalcones, flavanones, flavones, flavonols, and isoflavones. Selected examples of estrogenic flavonoids were further analyzed to determine their biological potencies and their relative affinities for binding to the estrogen receptor. These data are interpreted with respect to the molecular structure of polycyclic phenols required for hormonal activity as nonsteroidal estrogens.

  1. Predicting sample size required for classification performance

    Directory of Open Access Journals (Sweden)

    Figueroa Rosa L

    2012-02-01

    Full Text Available Abstract Background Supervised learning methods need annotated data in order to generate efficient models. Annotated data, however, is a relatively scarce resource and can be expensive to obtain. For both passive and active learning methods, there is a need to estimate the size of the annotated sample required to reach a performance target. Methods We designed and implemented a method that fits an inverse power law model to points of a given learning curve created using a small annotated training set. Fitting is carried out using nonlinear weighted least squares optimization. The fitted model is then used to predict the classifier's performance and confidence interval for larger sample sizes. For evaluation, the nonlinear weighted curve fitting method was applied to a set of learning curves generated using clinical text and waveform classification tasks with active and passive sampling methods, and predictions were validated using standard goodness of fit measures. As control we used an un-weighted fitting method. Results A total of 568 models were fitted and the model predictions were compared with the observed performances. Depending on the data set and sampling method, it took between 80 to 560 annotated samples to achieve mean average and root mean squared error below 0.01. Results also show that our weighted fitting method outperformed the baseline un-weighted method (p Conclusions This paper describes a simple and effective sample size prediction algorithm that conducts weighted fitting of learning curves. The algorithm outperformed an un-weighted algorithm described in previous literature. It can help researchers determine annotation sample size for supervised machine learning.

  2. Biological Sample Ambient Preservation (BioSAP) Device Project

    Data.gov (United States)

    National Aeronautics and Space Administration — To address NASA's need for alternative methods for ambient preservation of human biological samples collected during extended spaceflight and planetary operations,...

  3. Micro and Nano Techniques for the Handling of Biological Samples

    DEFF Research Database (Denmark)

    Micro and Nano Techniques for the Handling of Biological Samples reviews the different techniques available to manipulate and integrate biological materials in a controlled manner, either by sliding them along a surface (2-D manipulation), or by gripping and moving them to a new position (3-D...

  4. Manipulation of biological samples using micro and nano techniques

    DEFF Research Database (Denmark)

    Castillo, Jaime; Dimaki, Maria; Svendsen, Winnie Edith

    2009-01-01

    The constant interest in handling, integrating and understanding biological systems of interest for the biomedical field, the pharmaceutical industry and the biomaterial researchers demand the use of techniques that allow the manipulation of biological samples causing minimal or no damage to thei...

  5. Solid-phase microextraction for the analysis of biological samples

    NARCIS (Netherlands)

    Theodoridis, G; Koster, EHM; de Jong, GJ

    2000-01-01

    Solid-phase microextraction (SPME) has been introduced for the extraction of organic compounds from environmental samples. This relatively new extraction technique has now also gained a lot of interest in a broad field of analysis including food, biological and pharmaceutical samples. SPME has a num

  6. Stability of glufosfamide in phosphate buffers and in biological samples.

    Science.gov (United States)

    Sun, Yuming; Chen, Xiaoyan; Xu, Haiyan; Guan, Zhongmin; Zhong, Dafang

    2006-03-07

    Glufosfamide is a new, potential chemotherapeutic agent currently under investigation. Stability of glufosfamide was investigated in sodium phosphate buffers with different pH and temperature and in biological samples. Glufosfamide and isophosphamide mustard were quantified simultaneously using a liquid chromatography-ion trap mass spectrometric method; precision and accuracy were within 15% for each analyte. Glufosfamide was stable in neutral buffers, but decomposed to form isophosphoramide mustard under acidic and basic conditions, which was pH- and temperature-dependent. The stability of glufosfamide varied in different biological samples. Results indicated that glufosfamide was unstable in some biological samples, such as the small intestine, smooth muscles, pancreas and urine, especially in the small intestine homogenate, with a half-life of 1.1 h. But the pH (<8) and beta-glucosidase of the tissue homogenate was found to have negligible contribution to the degradation of glufosfamide. The enzymatic inhibition experiment with the specific inhibitor, saccharo-1,4-lactone, demonstrated that it was glucuronidase that resulted in the degradation of glufosfamide in small intestine homogenate. Methanol was recommended to be used to homogenize the tissue in an ice water bath, and the container for urine collection should also be maintained in an ice water bath, and all the biological samples collected should be preserved in frozen condition until analysis.

  7. 40 CFR 141.174 - Filtration sampling requirements.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 22 2010-07-01 2010-07-01 false Filtration sampling requirements. 141... PROGRAMS (CONTINUED) NATIONAL PRIMARY DRINKING WATER REGULATIONS Enhanced Filtration and Disinfection-Systems Serving 10,000 or More People § 141.174 Filtration sampling requirements. (a)...

  8. Using electron microscopy to calculate optical properties of biological samples.

    Science.gov (United States)

    Wu, Wenli; Radosevich, Andrew J; Eshein, Adam; Nguyen, The-Quyen; Yi, Ji; Cherkezyan, Lusik; Roy, Hemant K; Szleifer, Igal; Backman, Vadim

    2016-11-01

    The microscopic structural origins of optical properties in biological media are still not fully understood. Better understanding these origins can serve to improve the utility of existing techniques and facilitate the discovery of other novel techniques. We propose a novel analysis technique using electron microscopy (EM) to calculate optical properties of specific biological structures. This method is demonstrated with images of human epithelial colon cell nuclei. The spectrum of anisotropy factor g, the phase function and the shape factor D of the nuclei are calculated. The results show strong agreement with an independent study. This method provides a new way to extract the true phase function of biological samples and provides an independent validation for optical property measurement techniques.

  9. Preparation of Biological Samples Containing Metoprolol and Bisoprolol for Applying Methods for Quantitative Analysis

    Directory of Open Access Journals (Sweden)

    Corina Mahu Ştefania

    2015-12-01

    Full Text Available Arterial hypertension is a complex disease with many serious complications, representing a leading cause of mortality. Selective beta-blockers such as metoprolol and bisoprolol are frequently used in the management of hypertension. Numerous analytical methods have been developed for the determination of these substances in biological fluids, such as liquid chromatography coupled with mass spectrometry, gas chromatography coupled with mass spectrometry, high performance liquid chromatography. Due to the complex composition of biological fluids a biological sample pre-treatment before the use of the method for quantitative determination is required in order to remove proteins and potential interferences. The most commonly used methods for processing biological samples containing metoprolol and bisoprolol were identified through a thorough literature search using PubMed, ScienceDirect, and Willey Journals databases. Articles published between years 2005-2015 were reviewed. Protein precipitation, liquid-liquid extraction and solid phase extraction are the main techniques for the extraction of these drugs from plasma, serum, whole blood and urine samples. In addition, numerous other techniques have been developed for the preparation of biological samples, such as dispersive liquid-liquid microextraction, carrier-mediated liquid phase microextraction, hollow fiber-protected liquid phase microextraction, on-line molecularly imprinted solid phase extraction. The analysis of metoprolol and bisoprolol in human plasma, urine and other biological fluids provides important information in clinical and toxicological trials, thus requiring the application of appropriate extraction techniques for the detection of these antihypertensive substances at nanogram and picogram levels.

  10. Toxicological Analysis of Some Drugs of Abuse in Biological Samples

    Directory of Open Access Journals (Sweden)

    Anne Marie Ciobanu

    2015-10-01

    Full Text Available Consumption of drugs of abuse is a scourge of modern world. Abuse, drug addiction and their consequences are one of the major current problems of European society because of the significant repercussions in individual, family, social and economic level. In this context, toxicological analysis of the drugs of abuse in biological samples is a useful tool for: diagnosis of drug addiction, checking an auto-response, mandatory screening in some treatment programs, identification of a substance in the case of an overdose, determining compliance of the treatment. The present paper aims to address the needs of healthcare professionals involved in drugs addiction treatment through systematic presentation of information regarding their toxicological analysis. Basically, it is a tool that help you to select the suitable biological sample and the right collecting time, as well as the proper analysis technique, depending on the purpose of analysis, pharmacokinetic characteristics of the drugs of abuse, available equipment and staff expertise.

  11. Analytical methodologies for the determination of benzodiazepines in biological samples.

    Science.gov (United States)

    Persona, Karolina; Madej, Katarzyna; Knihnicki, Paweł; Piekoszewski, Wojciech

    2015-09-10

    Benzodiazepine drugs belong to important and most widely used medicaments. They demonstrate such therapeutic properties as anxiolytic, sedative, somnifacient, anticonvulsant, diastolic and muscle relaxant effects. However, despite the fact that benzodiazepines possess high therapeutic index and are considered to be relatively safe, their use can be dangerous when: (1) co-administered with alcohol, (2) co-administered with other medicaments like sedatives, antidepressants, neuroleptics or morphine like substances, (3) driving under their influence, (4) using benzodiazepines non-therapeutically as drugs of abuse or in drug-facilitated crimes. For these reasons benzodiazepines are still studied and determined in a variety of biological materials. In this article, sample preparation techniques which have been applied in analysis of benzodiazepine drugs in biological samples have been reviewed and presented. The next part of the article is focused on a review of analytical methods which have been employed for pharmacological, toxicological or forensic study of this group of drugs in the biological matrices. The review was preceded by a description of the physicochemical properties of the selected benzodiazepines and two, very often coexisting in the same analyzed samples, sedative-hypnotic drugs.

  12. Using biological samples in epidemiological research on drugs of abuse

    Directory of Open Access Journals (Sweden)

    Hallvard Gjerde

    2011-12-01

    Full Text Available Blood, oral fluid (saliva, urine and hair are the most commonly used biological matrices for drug testing in epidemiological drug research. Other biological matrices may also be used for selected purposes. Blood reflects recent drug intake and may be used to assess impairment. Oral fluid reflects drug presence in blood and thereby also recent intake, but drug concentrations in this matrix cannot be used to accurately estimate concentrations in blood. Urine reflects drug use during the last few days and in some cases for a longer period, but does not indicate the dose size or frequency of use. Hair reflects drug use during several months, but is a poor matrix for detecting use of cannabis. If using a single drug dose, this can be detected in blood and urine if the sample is taken within the detection timeframes, in most cases also in oral fluid. Single drug use is most often insufficient for producing a positive test result in a sample of hair. For cocaine and amphetamine, weekly use may be needed, while for cannabis a positive result is not guaranteed even after daily use. Refusal rates are lowest for oral fluid and highest for blood and hair samples. The analytical costs are lowest for urine and highest for hair. Combined use of questionnaires/interviews and drug testing detects more drug use than when using only one of those methods and is therefore expected to give more accurate data.

  13. Direct analysis of biological samples by total reflection X-ray fluorescence

    Energy Technology Data Exchange (ETDEWEB)

    Lue M, Marco P. [Unidad de Analisis Instrumental, Departamento de Quimica y Suelos, Decanato de Agronomia, Universidad Centro-occidental Lisandro Alvarado, Apartado Postal 4076, Cabudare 3023 (Venezuela)]. E-mail: luemerumarco@yahoo.es; Hernandez-Caraballo, Edwin A. [Instituto Venezolano-Andino para la Investigacion Quimica (IVAIQUIM), Facultad de Ciencias, Universidad de los Andes, Merida 5101 (Venezuela)

    2004-08-31

    The technique of total reflection X-ray fluorescence (TXRF) is well suited for the direct analysis of biological samples due to the low matrix interferences and simultaneous multi-element nature. Nevertheless, biological organic samples are frequently analysed after digestion procedures. The direct determination of analytes requires shorter analysis time, low reactive consumption and simplifies the whole analysis process. On the other hand, the biological/clinical samples are often available in minimal amounts and routine studies require the analysis of large number of samples. To overcome the difficulties associated with the analysis of organic samples, particularly of solid ones, different procedures of sample preparation and calibration to approach the direct analysis have been evaluated: (1) slurry sampling, (2) Compton peak standardization, (3) in situ microwave digestion, (4) in situ chemical modification and (5) direct analysis with internal standardization. Examples of analytical methods developed by our research group are discussed. Some of them have not been previously published, illustrating alternative strategies for coping with various problems that may be encountered in the direct analysis by total reflection X-ray fluorescence spectrometry.

  14. Sample Size Requirements for Estimating Pearson, Spearman and Kendall Correlations.

    Science.gov (United States)

    Bonett, Douglas G.; Wright, Thomas A.

    2000-01-01

    Reviews interval estimates of the Pearson, Kendall tau-alpha, and Spearman correlates and proposes an improved standard error for the Spearman correlation. Examines the sample size required to yield a confidence interval having the desired width. Findings show accurate results from a two-stage approximation to the sample size. (SLD)

  15. Incubation Station for the Bacterial Growth Study in Biological Samples

    Directory of Open Access Journals (Sweden)

    Carlos Rafael Duharte Rodríguez

    2015-12-01

    Full Text Available This work shows the designing and characterization of a prototype of laboratory incubator as support of Microbiology research, in particular for the research of the bacterial growth in biological samples through optic methods (Turbidimetry and electrometric measurements of bioimpedance. It shows the results of simulation and experimentation of the design proposed for the canals of measurement of the variables: temperature and humidity, with a high linearity from the adequate selection of the corresponding sensors and the analogue components of every canal, controlled with help of a microcontroller AT89C51 (ATMEL with adequate benefi ts for this type of application.

  16. Explaining Choice and Share of Category Requirements of Biologic Meat

    NARCIS (Netherlands)

    P.C. Verhoef (Peter); K. Vlagsma-Brangule (Kristine)

    2003-01-01

    textabstractIn this paper we examine factors determining choice and consumption of biologic or organic meat. In our model explaining choice and share of category requirements, we consider economic/marketing variables (quality, price, and distribution), emotions (fear, empathy, andguilt), social norm

  17. Microsystem strategies for sample preparation in biological detection.

    Energy Technology Data Exchange (ETDEWEB)

    James, Conrad D.; Galambos, Paul C.; Bennett, Dawn Jonita (University of Maryland Baltimore County, Baltimore, MD); Manginell, Monica; Okandan, Murat; Acrivos, Andreas (The City College of New York, NY); Brozik, Susan Marie; Khusid, Boris (New Jersey Institute of Technology, Newark, NJ)

    2005-03-01

    The objective of this LDRD was to develop microdevice strategies for dealing with samples to be examined in biological detection systems. This includes three sub-components: namely, microdevice fabrication, sample delivery to the microdevice, and sample processing within the microdevice. The first component of this work focused on utilizing Sandia's surface micromachining technology to fabricate small volume (nanoliter) fluidic systems for processing small quantities of biological samples. The next component was to develop interfaces for the surface-micromachined silicon devices. We partnered with Micronics, a commercial company, to produce fluidic manifolds for sample delivery to our silicon devices. Pressure testing was completed to examine the strength of the bond between the pressure-sensitive adhesive layer and the silicon chip. We are also pursuing several other methods, both in house and external, to develop polymer-based fluidic manifolds for packaging silicon-based microfluidic devices. The second component, sample processing, is divided into two sub-tasks: cell collection and cell lysis. Cell collection was achieved using dielectrophoresis, which employs AC fields to collect cells at energized microelectrodes, while rejecting non-cellular particles. Both live and dead Staph. aureus bacteria have been collected using RF frequency dielectrophoresis. Bacteria have been separated from polystyrene microspheres using frequency-shifting dielectrophoresis. Computational modeling was performed to optimize device separation performance, and to predict particle response to the dielectrophoretic traps. Cell lysis is continuing to be pursued using microactuators to mechanically disrupt cell membranes. Novel thermal actuators, which can generate larger forces than previously tested electrostatic actuators, have been incorporated with and tested with cell lysis devices. Significant cell membrane distortion has been observed, but more experiments need to be

  18. The use of contrast agent for imaging biological samples

    Energy Technology Data Exchange (ETDEWEB)

    Dammer, J; Sopko, V; Jakubek, J [Institute of Experimental and Applied Physics, Czech Technical University in Prague, Horska 3a/22, CZ 12800 Prague 2 (Czech Republic); Weyda, F, E-mail: jiri.dammer@utef.cvut.cz [Biological center of the Academy of Sciences of the Czech Republic, Institute of Entomology, Branisovska 31, CZ-37005 Ceske Budejovice (Czech Republic)

    2011-01-15

    The technique of X-ray transmission imaging has been available for over a century and is still among the fastest and easiest approaches to the studies of internal structure of biological samples. Recent advances in semiconductor technology have led to the development of new types of X-ray detectors with direct conversion of interacting X-ray photon to an electric signal. Semiconductor pixel detectors seem to be specially promising; compared to the film technique, they provide single-quantum and real-time digital information about the objects being studied. We describe the recently developed radiographic apparatus, equipped with Medipix2 semiconductor pixel detector. The detector is used as an imager that counts individual photons of ionizing radiation, emitted by an X-ray tube (micro- or nano-focus FeinFocus). Thanks to the wide dynamic range of the Medipix2 detector and its high spatial resolution better than 1{mu}m, the setup is particularly suitable for radiographic imaging of small biological samples, including in-vivo observations with contrast agent (Optiray). Along with the description of the apparatus we provide examples of the use iodine contrast agent as a tracer in various insects as model organisms. The motivation of our work is to develop our imaging techniques as non-destructive and non-invasive. Microradiographic imaging helps detect organisms living in a not visible environment, visualize the internal biological processes and also to resolve the details of their body (morphology). Tiny live insects are an ideal object for our studies.

  19. Spectroscopic analysis of bosentan in biological samples after a liquid-liquid microextraction

    Science.gov (United States)

    Sajedi-Amin, Sanaz; Assadpour-Zeynali, Karim; Panahi-Azar, Vahid; Kebriaeezadeh, Abbas; Khoubnasabjafari, Maryam; Ansarin, Khalil; Jouyban-Gharamaleki, Vahid; Jouyban, Abolghasem

    2015-01-01

    Introduction:Microextraction processes with UV-Vis measurement have been developed and validated for analysis of bosentan in biological samples. Methods:In this work, liquid–liquid microextraction procedures (DLLME & USAEME) were employed for cleanup, pre-concentration, and determination of bosentan in biological samples by UV-Vis spectroscopy at 270 nm. The method was validated and applied to the determination of bosentan in spiked serum, exhaled breath condensate and urine samples. Results:Various experimental factors including type of extraction and dispersive solvents and their volumes, pH, sonication time and centrifuging time were investigated. Under the optimum conditions, the method was linear in the range of 1.0–5.0 μg.mL-1, with coefficient of determination (R2) of > 0.998. The limit of detection (LOD) was 0.07 mg.L-1. Recovery of the target analyte in biological samples was 106.2%. The method could be easily applied for higher concentration of bosentan and needs more improvement for application in the pharmacokinetic investigations where more sensitive methods are required. Conclusion:A simple, low cost, precise and accurate spectrophotometric analysis of bosentan in biological samples after liquid-liquid microextraction were developed and validated for routine analyses. PMID:26929923

  20. Sample Size Requirements for Traditional and Regression-Based Norms.

    Science.gov (United States)

    Oosterhuis, Hannah E M; van der Ark, L Andries; Sijtsma, Klaas

    2016-04-01

    Test norms enable determining the position of an individual test taker in the group. The most frequently used approach to obtain test norms is traditional norming. Regression-based norming may be more efficient than traditional norming and is rapidly growing in popularity, but little is known about its technical properties. A simulation study was conducted to compare the sample size requirements for traditional and regression-based norming by examining the 95% interpercentile ranges for percentile estimates as a function of sample size, norming method, size of covariate effects on the test score, test length, and number of answer categories in an item. Provided the assumptions of the linear regression model hold in the data, for a subdivision of the total group into eight equal-size subgroups, we found that regression-based norming requires samples 2.5 to 5.5 times smaller than traditional norming. Sample size requirements are presented for each norming method, test length, and number of answer categories. We emphasize that additional research is needed to establish sample size requirements when the assumptions of the linear regression model are violated.

  1. Micro-radiography of biological samples with medical contrast agents

    Energy Technology Data Exchange (ETDEWEB)

    Dammer, J., E-mail: jiri.dammer@lf1.cuni.cz [Charles University in Prague, First Faculty of Medicine, Salmovská 1, 120 00 Prague 2 (Czech Republic); Hospital Na Bulovce, Department of Radiological Physics, Budinova 2, 180 81 Prague 8 (Czech Republic); Institute of Experimental and Applied Physics, Czech Technical University in Prague, Horska 3a/22, 128 00 Prague 2 (Czech Republic); Weyda, F. [Faculty of Science, University of South Bohemia, Branisovska 31, 370 05 Ceske Budejovice (Czech Republic); Benes, J. [Charles University in Prague, First Faculty of Medicine, Salmovská 1, 120 00 Prague 2 (Czech Republic); Sopko, V. [Hospital Na Bulovce, Department of Radiological Physics, Budinova 2, 180 81 Prague 8 (Czech Republic); Institute of Experimental and Applied Physics, Czech Technical University in Prague, Horska 3a/22, 128 00 Prague 2 (Czech Republic); Gelbic, I. [Biology Centre, AS CR, Institute of Entomology, Department of Biochemistry and Physiology, Branisovska 31, CZ-37005 Ceske Budejovice (Czech Republic)

    2013-12-01

    Micro-radiography is an imaging technique that uses X-rays to study the internal structures of objects. This fast and easy imaging tool is based on differential X-ray attenuation by various tissues and structures within biological samples. The experimental setup described is based on the semiconductor pixel X-ray detector Medipix2 and X-ray micro-focus tube. Our micro-radiographic system has been recently used not only for the examination of internal structures of various arthropods and other biological objects but also for tracing some processes in selected model species (we used living larvae of mosquito Culex quinquefasciatus). Low concentrations of iodine, lanthanum or gold particles were used as a tracer (contrast agent). Such contrast agents increase the absorption of X-rays and allow a better visibility of internal structures of model organisms (especially the various cavities, pores, etc.). In addition, the movement of tracers in selected timing experiments demonstrates some physiological functions of digestive and excretory system.

  2. Digital holography microscopy in 3D biologic samples analysis

    Energy Technology Data Exchange (ETDEWEB)

    Ricardo, J O; Palacios, F; Palacios, G F; Sanchez, A [Department of Physics, University of Oriente (Cuba); Muramatsu, M [Department of General Physics, University of Sao Paulo - Sao Paulo (Brazil); Gesualdi, M [Engineering center, Models and Applied Social Science, UFABC - Sao Paulo (Brazil); Font, O [Department of Bio-ingeniering, University of Oriente - Santiago de Cuba (Cuba); Valin, J L [Mechanics Department, ISPJAE, Habana (Cuba); Escobedo, M; Herold, S [Department of Computation, University of Oriente (Cuba); Palacios, D F, E-mail: frpalaciosf@gmail.com [Department of Nuclear physics, University of Simon BolIva (Venezuela, Bolivarian Republic of)

    2011-01-01

    In this work it is used a setup for Digital Holography Microscopy (MHD) for 3D biologic samples reconstruction. The phase contrast image reconstruction is done by using the Double propagation Method. The system was calibrated and tested by using a micrometric scale and pure phase object respectively. It was simulated the human red blood cell (erythrocyte) and beginning from the simulated hologram the digital 3D phase image for erythrocytes it was calculated. Also there was obtained experimental holograms of human erythrocytes and its corresponding 3D phase images, being evident the correspondence qualitative and quantitative between these characteristics in the simulated erythrocyte and in the experimentally calculated by DHM in both cases.

  3. Microfluidic solutions enabling continuous processing and monitoring of biological samples: A review.

    Science.gov (United States)

    Karle, Marc; Vashist, Sandeep Kumar; Zengerle, Roland; von Stetten, Felix

    2016-07-27

    The last decade has witnessed tremendous advances in employing microfluidic solutions enabling Continuous Processing and Monitoring of Biological Samples (CPMBS), which is an essential requirement for the control of bio-processes. The microfluidic systems are superior to the traditional inline sensors due to their ability to implement complex analytical procedures, such as multi-step sample preparation, and enabling the online measurement of parameters. This manuscript provides a backgound review of microfluidic approaches employing laminar flow, hydrodynamic separation, acoustophoresis, electrophoresis, dielectrophoresis, magnetophoresis and segmented flow for the continuous processing and monitoring of biological samples. The principles, advantages and limitations of each microfluidic approach are described along with its potential applications. The challenges in the field and the future directions are also provided.

  4. The NYC native air sampling pilot project: using HVAC filter data for urban biological incident characterization.

    Science.gov (United States)

    Ackelsberg, Joel; Leykam, Frederic M; Hazi, Yair; Madsen, Larry C; West, Todd H; Faltesek, Anthony; Henderson, Gavin D; Henderson, Christopher L; Leighton, Terrance

    2011-09-01

    Native air sampling (NAS) is distinguished from dedicated air sampling (DAS) devices (eg, BioWatch) that are deployed to detect aerosol disseminations of biological threat agents. NAS uses filter samples from heating, ventilation, and air conditioning (HVAC) systems in commercial properties for environmental sampling after DAS detection of biological threat agent incidents. It represents an untapped, scientifically sound, efficient, widely distributed, and comparably inexpensive resource for postevent environmental sampling. Calculations predict that postevent NAS would be more efficient than environmental surface sampling by orders of magnitude. HVAC filter samples could be collected from pre-identified surrounding NAS facilities to corroborate the DAS alarm and delineate the path taken by the bioaerosol plume. The New York City (NYC) Native Air Sampling Pilot Project explored whether native air sampling would be acceptable to private sector stakeholders and could be implemented successfully in NYC. Building trade associations facilitated outreach to and discussions with property owners and managers, who expedited contact with building managers of candidate NAS properties that they managed or owned. Nominal NAS building requirements were determined; procedures to identify and evaluate candidate NAS facilities were developed; data collection tools and other resources were designed and used to expedite candidate NAS building selection and evaluation in Manhattan; and exemplar environmental sampling playbooks for emergency responders were completed. In this sample, modern buildings with single or few corporate tenants were the best NAS candidate facilities. The Pilot Project successfully demonstrated that in one urban setting a native air sampling strategy could be implemented with effective public-private collaboration.

  5. Direct observation of unstained wet biological samples by scanning-electron generation X-ray microscopy.

    Science.gov (United States)

    Ogura, Toshihiko

    2010-01-01

    Analytical tools of nanometre-scale resolution are indispensable in the fields of biology, physics and chemistry. One suitable tool, the soft X-ray microscope, provides high spatial resolution of visible light for wet specimens. For biological specimens, X-rays of water-window wavelength between carbon (284 eV; 4.3 nm) and oxygen (540 eV; 2.3 nm) absorption edges provide high-contrast imaging of biological samples in water. Among types of X-ray microscope, the transmission X-ray microscope using a synchrotron radiation source with diffractive zone plates offers the highest spatial resolution, approaching 15-10nm. However, even higher resolution is required to measure proteins and protein complexes in biological specimens; therefore, a new type of X-ray microscope with higher resolution that uses a simple light source is desirable. Here we report a novel scanning-electron generation X-ray microscope (SGXM) that demonstrates direct imaging of unstained wet biological specimens. We deposited wet yeasts in the space between two silicon nitride (Si(3)N(4)) films. A scanning electron beam of accelerating voltage 5 keV and current 1.6 nA irradiates the titanium (Ti)-coated Si(3)N(4) film, and the soft X-ray signal from it is detected by an X-ray photodiode (PD) placed below the sample. The SGXM can theoretically achieve better than 5 nm resolution. Our method can be utilized easily for various wet biological samples of bacteria, viruses, and protein complexes.

  6. Amchitka Island, Alaska, Biological Monitoring Report 2011 Sampling Results

    Energy Technology Data Exchange (ETDEWEB)

    None

    2013-09-01

    The Long-Term Surveillance and Maintenance (LTS&M) Plan for the U.S. Department of Energy (DOE) Office of Legacy Management (LM) Amchitka Island sites describes how LM plans to conduct its mission to protect human health and the environment at the three nuclear test sites located on Amchitka Island, Alaska. Amchitka Island, near the western end of the Aleutian Islands, is approximately 1,340 miles west-southwest of Anchorage, Alaska. Amchitka is part of the Aleutian Island Unit of the Alaska Maritime National Wildlife Refuge, which is administered by the U.S. Fish and Wildlife Service (USFWS). Since World War II, Amchitka has been used by multiple U.S. government agencies for various military and research activities. From 1943 to 1950, it was used as a forward air base for the U.S. Armed Forces. During the middle 1960s and early 1970s, the U.S. Department of Defense (DOD) and the U.S. Atomic Energy Commission (AEC) used a portion of the island as a site for underground nuclear tests. During the late 1980s and early 1990s, the U.S. Navy constructed and operated a radar station on the island. Three underground nuclear tests were conducted on Amchitka Island. DOD, in conjunction with AEC, conducted the first nuclear test (named Long Shot) in 1965 to provide data that would improve the United States' capability of detecting underground nuclear explosions. The second nuclear test (Milrow) was a weapons-related test conducted by AEC in 1969 as a means to study the feasibility of detonating a much larger device. Cannikin, the third nuclear test on Amchitka, was a weapons-related test detonated on November 6, 1971. With the exception of small concentrations of tritium detected in surface water shortly after the Long Shot test, radioactive fission products from the tests remain in the subsurface at each test location As a continuation of the environmental monitoring that has taken place on Amchitka Island since before 1965, LM in the summer of 2011 collected biological

  7. RNA SAMPLE PREPARATION APPLIED TO GENE EXPRESSION PROFILING FOR THE HORSE BIOLOGICAL PASSPORT.

    Science.gov (United States)

    Bailly-Chouriberry, Ludovic; Baudoin, Florent; Cormant, Florence; Glavieux, Yohan; Loup, Benoit; Garcia, Patrice; Popot, Marie-Agnès; Bonnaire, Yves

    2017-04-05

    The improvement of doping control is an on-going race. Techniques to fight against doping are usually based on the direct detection of drugs or their metabolites by analytical methods such as chromatography hyphenated to mass spectrometry after ad hoc sample preparation. Nowadays, omic methods constitute an attractive development and advances have been achieved particularly by application of molecular biology tools for detection of anabolic androgenic steroids (AAS), erythropoiesis-stimulating agent (ESA) or to control human growth hormone misuses. These interesting results across different animal species have suggested that modification of gene expression offers promising new methods of improving the window of detection of banned substances by targeting their effects on blood cell gene expression. In this context, the present study describes the possibility of using a modified version of the dedicated Human IVD (in vitro Diagnostics) PAXgene® Blood RNA Kit for horse gene expression analysis in blood collected on PAXgene® tubes applied to the Horse Biological Passport. The commercial kit was only approved for human blood samples and has required an optimization of specific technical requirements for equine blood samples. Improvements and recommendations were achieved for sample collection, storage and RNA extraction procedure. Following these developments, RNA yield and quality were demonstrated to be suitable for downstream gene expression analysis by qPCR techniques.

  8. Using electron microscopy to calculate optical properties of biological samples

    OpenAIRE

    Wu, Wenli; Radosevich, Andrew J.; Eshein, Adam; Nguyen, The-Quyen; Yi, Ji; Cherkezyan, Lusik; Roy, Hemant K.; Szleifer, Igal; Backman, Vadim

    2016-01-01

    The microscopic structural origins of optical properties in biological media are still not fully understood. Better understanding these origins can serve to improve the utility of existing techniques and facilitate the discovery of other novel techniques. We propose a novel analysis technique using electron microscopy (EM) to calculate optical properties of specific biological structures. This method is demonstrated with images of human epithelial colon cell nuclei. The spectrum of anisotropy...

  9. 28 CFR 28.22 - The requirement to preserve biological evidence.

    Science.gov (United States)

    2010-07-01

    ... biological evidence does not apply at the investigative stage of criminal cases, occurring prior to the... 28 Judicial Administration 1 2010-07-01 2010-07-01 false The requirement to preserve biological... Preservation of Biological Evidence § 28.22 The requirement to preserve biological evidence. (a)...

  10. Spectroscopic analysis of bosentan in biological samples after a liquid-liquid microextraction

    Directory of Open Access Journals (Sweden)

    Sanaz Sajedi-Amin

    2015-12-01

    Conclusion: A simple, low cost, precise and accurate spectrophotometric analysis of bosentan in biological samples after liquid-liquid microextraction were developed and validated for routine analyses.

  11. The scope of detector Medipix2 in micro-radiography of biological samples

    Energy Technology Data Exchange (ETDEWEB)

    Dammer, J., E-mail: jiri.dammer@utef.cvut.cz [Institute of Experimental and Applied Physics, Czech Technical University in Prague, Horska 3a/22, CZ-12800 Prague 2 (Czech Republic); Weyda, F. [Biology Centre of the Academy of Sciences of the Czech Republic, Institute of Entomology, Branisovska 31, CZ-37005 Ceske Budejovice (Czech Republic); Faculty of Science, University of South Bohemia, Branisovska 31, CZ-37005 Ceske Budejovice (Czech Republic); Jakubek, J. [Institute of Experimental and Applied Physics, Czech Technical University in Prague, Horska 3a/22, CZ-12800 Prague 2 (Czech Republic); Skrabal, P. [Faculty of Biomedical Engineering, Czech Technical University in Prague, Nam. Sitna 3105, CZ-272 01 Kladno (Czech Republic); Sopko, V.; Vavrik, D. [Institute of Experimental and Applied Physics, Czech Technical University in Prague, Horska 3a/22, CZ-12800 Prague 2 (Czech Republic)

    2011-05-15

    We present our experimental setup devoted to high resolution X-ray micro-radiography that is suitable for imaging of small biological samples. The photon source is a FeinFocus micro-focus X-ray tube. The single photon counting pixel device Medipix2 serves as imaging area. Recently used imaging detectors as radiography films or scintillator detectors, cannot visualize required information about inner structure of scanned sample. Detectors Medipix2 do not suffer from so-called dark current noise and work in unlimited dynamic range. These features of detectors confer high quality and high contrast of final images. The radiographic imaging with detectors Medipix2 represents non-invasive and non-destructive method of investigation. Hereby, we demonstrate results of micro-radiographic study of internal structures of tiny biological samples. In addition to morphological and anatomical studies, we would like to present preliminary study of dynamic processes inside of organisms using micro-radiographic video-capturing.

  12. Challenges of biological sample preparation for SIMS imaging of elements and molecules at subcellular resolution

    Energy Technology Data Exchange (ETDEWEB)

    Chandra, Subhash [Cornell SIMS Laboratory, Department of Earth and Atmospheric Sciences, Snee Hall, Cornell University, Ithaca, NY 14853 (United States)], E-mail: sc40@cornell.edu

    2008-12-15

    Secondary ion mass spectrometry (SIMS) based imaging techniques capable of subcellular resolution characterization of elements and molecules are becoming valuable tools in many areas of biology and medicine. Due to high vacuum requirements of SIMS, the live cells cannot be analyzed directly in the instrument. The sample preparation, therefore, plays a critical role in preserving the native chemical composition for SIMS analysis. This work focuses on the evaluation of frozen-hydrated and frozen freeze-dried sample preparations for SIMS studies of cultured cells with a CAMECA IMS-3f dynamic SIMS ion microscope instrument capable of producing SIMS images with a spatial resolution of 500 nm. The sandwich freeze-fracture method was used for fracturing the cells. The complimentary fracture planes in the plasma membrane were characterized by field-emission secondary electron microscopy (FESEM) in the frozen-hydrated state. The cells fractured at the dorsal surface were used for SIMS analysis. The frozen-hydrated SIMS analysis of individual cells under dynamic primary ion beam (O{sub 2}{sup +}) revealed local secondary ion signal enhancements correlated with the water image signals of {sup 19}(H{sub 3}O){sup +}. A preferential removal of water from the frozen cell matrix in the Z-axis was also observed. These complications render the frozen-hydrated sample type less desirable for subcellular dynamic SIMS studies. The freeze-drying of frozen-hydrated cells, either inside the instrument or externally in a freeze-drier, allowed SIMS imaging of subcellular chemical composition. Morphological evaluations of fractured freeze-dried cells with SEM and confocal laser scanning microscopy (CLSM) revealed well-preserved mitochondria, Golgi apparatus, and stress fibers. SIMS analysis of fractured freeze-dried cells revealed well-preserved chemical composition of even the most highly diffusible ions like K{sup +} and Na{sup +} in physiologically relevant concentrations. The high K

  13. Alteration of biological samples in speciation analysis of metalloproteins.

    Science.gov (United States)

    Wolf, Christian; Wenda, Nadine; Richter, Andrea; Kyriakopoulos, Antonios

    2007-10-01

    For investigations of metalloproteins by speciation analysis, the integrity of the protein-metal complexes before and during separation is crucial. Knowledge about potential alterations of the samples is thus essential to avoid misinterpretations of the analytical results. Chromatographic element profiles of different cytosolic samples from animal tissues were measured repeatedly to estimate the sample stability. The dependence of the signals on the dwell time of the sample in an autosampling device at 4 degrees C for a period of 10 h was observed. Alterations in the element content of different metal-containing fractions were quantified by means of recovery values. Some metalloprotein fractions (e.g. approximately 27-kDa arsenic, approximately 27-kDa iron and different zinc fractions) were stable or only minor alterations were observed and for their investigation an autosampling device is therefore suitable. However, most of the other metalloprotein fractions, especially nickel-containing proteins, showed major alterations: these samples should therefore be analysed immediately after preparation or directly after thawing.

  14. Surface-enhanced Raman scattering detection of silver nanoparticles in environmental and biological samples.

    Science.gov (United States)

    Guo, Huiyuan; Xing, Baoshan; Hamlet, Leigh C; Chica, Andrea; He, Lili

    2016-06-01

    Growing concerns over the potential release and threat of silver nanoparticles (AgNPs) to environmental and biological systems urge researchers to investigate their fate and behavior. However, current analytical techniques cannot meet the requirements for rapidly, sensitively and reliably probing AgNPs in complex matrices. Surface-enhanced Raman spectroscopy (SERS) has shown great capability for rapid detection of AgNPs based on an indicator molecule that can bind on the AgNP surface. The objective of this study was to exploit SERS to detect AgNPs in environmental and biological samples through optimizing the Raman indicator for SERS. Seven indicator molecules were selected and determined to obtain their SERS signals at optimal concentrations. Among them, 1,2-di(4-pyridyl)ethylene (BPE), crystal violet and ferric dimethyl-dithiocarbamate (ferbam) produced the highest SERS intensities. Further experiments on binding competition between each two of the three candidates showed that ferbam had the highest AgNPs-binding ability. The underlying mechanism lies in the strong binding affinity of ferbam with AgNPs via multiple sulfur atoms. We further validated ferbam to be an effective indicator for SERS detection of as low as 0.1mg/L AgNPs in genuine surface water and 0.57 mg/L in spinach juice. Moreover, limited interference on SERS detection of AgNPs was found from environmentally relevant inorganic ions, organic matter, inorganic particles, as well as biologically relevant components, demonstrating the ferbam-assisted SERS is an effective and sensitive method to detect AgNPs in complex environmental and biological samples.

  15. Deep Penetration of Charged Particles in Biological Samples

    Institute of Scientific and Technical Information of China (English)

    WANG Rui-Jin; MU Yu-Guang; ZHAO Ming-Wen; MA Yu-Chen; XIA Yue-Yuan; LIU Xiang-Dong; LIU Ji-Tian; ZHANG Jian-Hua; YU Zeng-Liang

    2001-01-01

    Experimental evidence of abnormally deep penetration in some botanical targets by low-energy ion beams is presented. The energy spectra of 818kev He+ ions penetrating a 70μm thick seed coat of maize, fruit peel of grape and of tomato all have a common feature. The leading edges of these broad spectra indicate that some of the penetrating ions pass through the thick targets easily and only lose a small fraction of their initial incident energy. Rutherford backscattering spectrometry and electron microprobe measurements are used to determine the argon concentration in multilayer samples of the seed coat of maize implanted by 200 kev Ar+ ions. The results show that about 10% of the Ar+ ions can penetrate deeper than ~l00 μm in these samples.

  16. Deep Penetration of Charged Particles in Biological Samples

    Science.gov (United States)

    Wang, Rui-Jin; Xia, Yue-Yuan; Mu, Yu-Guang; Zhao, Ming-Wen; Ma, Yu-Chen; Liu, Xiang-Dong; Zhang, Jian-Hua; Liu, Ji-Tian; Yu, Zeng-Liang

    2001-02-01

    Experimental evidence of abnormally deep penetration in some botanical targets by low-energy ion beams is presented. The energy spectra of 818 keV He+ ions penetrating a 70 µm thick seed coat of maize, fruit peel of grape and of tomato all have a common feature. The leading edges of these broad spectra indicate that some of the penetrating ions pass through the thick targets easily and only lose a small fraction of their initial incident energy. Rutherford backscattering spectrometry and electron microprobe measurements are used to determine the argon concentration in multilayer samples of the seed coat of maize implanted by 200 keV Ar+ ions. The results show that about 10% of the Ar+ ions can penetrate deeper than ~100 µm in these samples.

  17. Micro-differential scanning calorimeter for liquid biological samples

    Science.gov (United States)

    Wang, Shuyu; Yu, Shifeng; Siedler, Michael S.; Ihnat, Peter M.; Filoti, Dana I.; Lu, Ming; Zuo, Lei

    2016-10-01

    We developed an ultrasensitive micro-DSC (differential scanning calorimeter) for liquid protein sample characterization. This design integrated vanadium oxide thermistors and flexible polymer substrates with microfluidics chambers to achieve a high sensitivity (6 V/W), low thermal conductivity (0.7 mW/K), high power resolutions (40 nW), and well-defined liquid volume (1 μl) calorimeter sensor in a compact and cost-effective way. We further demonstrated the performance of the sensor with lysozyme unfolding. The measured transition temperature and enthalpy change were in accordance with the previous literature data. This micro-DSC could potentially raise the prospect of high-throughput biochemical measurement by parallel operation with miniaturized sample consumption.

  18. Surface-enhanced Raman scattering detection of silver nanoparticles in environmental and biological samples

    Energy Technology Data Exchange (ETDEWEB)

    Guo, Huiyuan [Stockbridge School of Agriculture, University of Massachusetts, Amherst, MA 01003 (United States); Xing, Baoshan, E-mail: bx@umass.edu [Stockbridge School of Agriculture, University of Massachusetts, Amherst, MA 01003 (United States); Hamlet, Leigh C.; Chica, Andrea [Stockbridge School of Agriculture, University of Massachusetts, Amherst, MA 01003 (United States); He, Lili, E-mail: lilihe@foodsci.umass.edu [Department of Food Science, University of Massachusetts, Amherst, MA 01003 (United States)

    2016-06-01

    Growing concerns over the potential release and threat of silver nanoparticles (AgNPs) to environmental and biological systems urge researchers to investigate their fate and behavior. However, current analytical techniques cannot meet the requirements for rapidly, sensitively and reliably probing AgNPs in complex matrices. Surface-enhanced Raman spectroscopy (SERS) has shown great capability for rapid detection of AgNPs based on an indicator molecule that can bind on the AgNP surface. The objective of this study was to exploit SERS to detect AgNPs in environmental and biological samples through optimizing the Raman indicator for SERS. Seven indicator molecules were selected and determined to obtain their SERS signals at optimal concentrations. Among them, 1,2-di(4-pyridyl)ethylene (BPE), crystal violet and ferric dimethyl-dithiocarbamate (ferbam) produced the highest SERS intensities. Further experiments on binding competition between each two of the three candidates showed that ferbam had the highest AgNPs-binding ability. The underlying mechanism lies in the strong binding affinity of ferbam with AgNPs via multiple sulfur atoms. We further validated ferbam to be an effective indicator for SERS detection of as low as 0.1 mg/L AgNPs in genuine surface water and 0.57 mg/L in spinach juice. Moreover, limited interference on SERS detection of AgNPs was found from environmentally relevant inorganic ions, organic matter, inorganic particles, as well as biologically relevant components, demonstrating the ferbam-assisted SERS is an effective and sensitive method to detect AgNPs in complex environmental and biological samples. - Graphical abstract: SERS signal intensity of ferbam indicates the concentration of AgNPs. - Highlights: • Ferbam was found to be the best indicator for SERS detection of AgNPs. • SERS was able to detect AgNPs in both environmental and biological samples. • Major components in the two matrices had limited effect on AgNP detection.

  19. Elemental distribution and sample integrity comparison of freeze-dried and frozen-hydrated biological tissue samples with nuclear microprobe

    Energy Technology Data Exchange (ETDEWEB)

    Vavpetič, P., E-mail: primoz.vavpetic@ijs.si [Jožef Stefan Institute, Jamova 39, SI-1000 Ljubljana (Slovenia); Vogel-Mikuš, K. [Biotechnical Faculty, Department of Biology, University of Ljubljana, Jamnikarjeva 101, SI-1000 Ljubljana (Slovenia); Jeromel, L. [Jožef Stefan Institute, Jamova 39, SI-1000 Ljubljana (Slovenia); Ogrinc Potočnik, N. [Jožef Stefan Institute, Jamova 39, SI-1000 Ljubljana (Slovenia); FOM-Institute AMOLF, Science Park 104, 1098 XG Amsterdam (Netherlands); Pongrac, P. [Biotechnical Faculty, Department of Biology, University of Ljubljana, Jamnikarjeva 101, SI-1000 Ljubljana (Slovenia); Department of Plant Physiology, University of Bayreuth, Universitätstr. 30, 95447 Bayreuth (Germany); Drobne, D.; Pipan Tkalec, Ž.; Novak, S.; Kos, M.; Koren, Š.; Regvar, M. [Biotechnical Faculty, Department of Biology, University of Ljubljana, Jamnikarjeva 101, SI-1000 Ljubljana (Slovenia); Pelicon, P. [Jožef Stefan Institute, Jamova 39, SI-1000 Ljubljana (Slovenia)

    2015-04-01

    The analysis of biological samples in frozen-hydrated state with micro-PIXE technique at Jožef Stefan Institute (JSI) nuclear microprobe has matured to a point that enables us to measure and examine frozen tissue samples routinely as a standard research method. Cryotome-cut slice of frozen-hydrated biological sample is mounted between two thin foils and positioned on the sample holder. The temperature of the cold stage in the measuring chamber is kept below 130 K throughout the insertion of the samples and the proton beam exposure. Matrix composition of frozen-hydrated tissue is consisted mostly of ice. Sample deterioration during proton beam exposure is monitored during the experiment, as both Elastic Backscattering Spectrometry (EBS) and Scanning Transmission Ion Microscopy (STIM) in on–off axis geometry are recorded together with the events in two PIXE detectors and backscattered ions from the chopper in a single list-mode file. The aim of this experiment was to determine differences and similarities between two kinds of biological sample preparation techniques for micro-PIXE analysis, namely freeze-drying and frozen-hydrated sample preparation in order to evaluate the improvements in the elemental localisation of the latter technique if any. In the presented work, a standard micro-PIXE configuration for tissue mapping at JSI was used with five detection systems operating in parallel, with proton beam cross section of 1.0 × 1.0 μm{sup 2} and a beam current of 100 pA. The comparison of the resulting elemental distributions measured at the biological tissue prepared in the frozen-hydrated and in the freeze-dried state revealed differences in elemental distribution of particular elements at the cellular level due to the morphology alteration in particular tissue compartments induced either by water removal in the lyophilisation process or by unsatisfactory preparation of samples for cutting and mounting during the shock-freezing phase of sample preparation.

  20. Elemental distribution and sample integrity comparison of freeze-dried and frozen-hydrated biological tissue samples with nuclear microprobe

    Science.gov (United States)

    Vavpetič, P.; Vogel-Mikuš, K.; Jeromel, L.; Ogrinc Potočnik, N.; Pongrac, P.; Drobne, D.; Pipan Tkalec, Ž.; Novak, S.; Kos, M.; Koren, Š.; Regvar, M.; Pelicon, P.

    2015-04-01

    The analysis of biological samples in frozen-hydrated state with micro-PIXE technique at Jožef Stefan Institute (JSI) nuclear microprobe has matured to a point that enables us to measure and examine frozen tissue samples routinely as a standard research method. Cryotome-cut slice of frozen-hydrated biological sample is mounted between two thin foils and positioned on the sample holder. The temperature of the cold stage in the measuring chamber is kept below 130 K throughout the insertion of the samples and the proton beam exposure. Matrix composition of frozen-hydrated tissue is consisted mostly of ice. Sample deterioration during proton beam exposure is monitored during the experiment, as both Elastic Backscattering Spectrometry (EBS) and Scanning Transmission Ion Microscopy (STIM) in on-off axis geometry are recorded together with the events in two PIXE detectors and backscattered ions from the chopper in a single list-mode file. The aim of this experiment was to determine differences and similarities between two kinds of biological sample preparation techniques for micro-PIXE analysis, namely freeze-drying and frozen-hydrated sample preparation in order to evaluate the improvements in the elemental localisation of the latter technique if any. In the presented work, a standard micro-PIXE configuration for tissue mapping at JSI was used with five detection systems operating in parallel, with proton beam cross section of 1.0 × 1.0 μm2 and a beam current of 100 pA. The comparison of the resulting elemental distributions measured at the biological tissue prepared in the frozen-hydrated and in the freeze-dried state revealed differences in elemental distribution of particular elements at the cellular level due to the morphology alteration in particular tissue compartments induced either by water removal in the lyophilisation process or by unsatisfactory preparation of samples for cutting and mounting during the shock-freezing phase of sample preparation.

  1. Nanocharacterization of Soft Biological Samples in Shear Mode with Quartz Tuning Fork Probes

    OpenAIRE

    Manel Puig-Vidal; Laura Gonzalez; Jorge Otero

    2012-01-01

    Quartz tuning forks are extremely good resonators and their use is growing in scanning probe microscopy. Nevertheless, only a few studies on soft biological samples have been reported using these probes. In this work, we present the methodology to develop and use these nanosensors to properly work with biological samples. The working principles, fabrication and experimental setup are presented. The results in the nanocharacterization of different samples in different ambients are presented by...

  2. A comparison of quantitative reconstruction techniques for PIXE-tomography analysis applied to biological samples

    Energy Technology Data Exchange (ETDEWEB)

    Beasley, D.G., E-mail: dgbeasley@ctn.ist.utl.pt [IST/C2TN, Universidade de Lisboa, Campus Tecnológico e Nuclear, E.N.10, 2686-953 Sacavém (Portugal); Alves, L.C. [IST/C2TN, Universidade de Lisboa, Campus Tecnológico e Nuclear, E.N.10, 2686-953 Sacavém (Portugal); Barberet, Ph.; Bourret, S.; Devès, G.; Gordillo, N.; Michelet, C. [Univ. Bordeaux, CENBG, UMR 5797, F-33170 Gradignan (France); CNRS, IN2P3, CENBG, UMR 5797, F-33170 Gradignan (France); Le Trequesser, Q. [Univ. Bordeaux, CENBG, UMR 5797, F-33170 Gradignan (France); CNRS, IN2P3, CENBG, UMR 5797, F-33170 Gradignan (France); Institut de Chimie de la Matière Condensée de Bordeaux (ICMCB, UPR9048) CNRS, Université de Bordeaux, 87 avenue du Dr. A. Schweitzer, Pessac F-33608 (France); Marques, A.C. [IST/IPFN, Universidade de Lisboa, Campus Tecnológico e Nuclear, E.N.10, 2686-953 Sacavém (Portugal); Seznec, H. [Univ. Bordeaux, CENBG, UMR 5797, F-33170 Gradignan (France); CNRS, IN2P3, CENBG, UMR 5797, F-33170 Gradignan (France); Silva, R.C. da [IST/IPFN, Universidade de Lisboa, Campus Tecnológico e Nuclear, E.N.10, 2686-953 Sacavém (Portugal)

    2014-07-15

    The tomographic reconstruction of biological specimens requires robust algorithms, able to deal with low density contrast and low element concentrations. At the IST/ITN microprobe facility new GPU-accelerated reconstruction software, JPIXET, has been developed, which can significantly increase the speed of quantitative reconstruction of Proton Induced X-ray Emission Tomography (PIXE-T) data. It has a user-friendly graphical user interface for pre-processing, data analysis and reconstruction of PIXE-T and Scanning Transmission Ion Microscopy Tomography (STIM-T). The reconstruction of PIXE-T data is performed using either an algorithm based on a GPU-accelerated version of the Maximum Likelihood Expectation Maximisation (MLEM) method or a GPU-accelerated version of the Discrete Image Space Reconstruction Algorithm (DISRA) (Sakellariou (2001) [2]). The original DISRA, its accelerated version, and the MLEM algorithm, were compared for the reconstruction of a biological sample of Caenorhabditis elegans – a small worm. This sample was analysed at the microbeam line of the AIFIRA facility of CENBG, Bordeaux. A qualitative PIXE-T reconstruction was obtained using the CENBG software package TomoRebuild (Habchi et al. (2013) [6]). The effects of pre-processing and experimental conditions on the elemental concentrations are discussed.

  3. Multiphoton imaging of biological samples during freezing and heating

    Science.gov (United States)

    Breunig, H. G.; Uchugonova, A.; König, K.

    2014-02-01

    We applied multiphoton microscopic imaging to observe freezing and heating effects in plant- and animal cell samples. The experimental setups consisted of a multiphoton imaging system and a heating and cooling stage which allows for precise temperature control from liquid nitrogen temperature (-196°C 77 K) up to +600°C (873 K) with heating/freezing rates between 0.01 K/min and 150 K/min. Two multiphoton imaging systems were used: a system based on a modified optical microscope and a flexible mobile system. To illustrate the imaging capabilities, plant leafs as well as animal cells were microscopically imaged in vivo during freezing based on autofluorescence lifetime and intensity of intrinsic molecules. The measurements illustrate the usefulness of multiphoton imaging to investigate freezing effects on animal and plant cells.

  4. Comparative analysis of toxin detection in biological and enviromental samples

    Science.gov (United States)

    Ogert, Robert A.; Burans, James; O'Brien, Tom; Ligler, Frances S.

    1994-03-01

    The basic recognition schemes underlying the principles of standard enzyme-linked immunosorbent assay (ELISA) and radioimmunoassay (RIA) protocols are increasingly being adapted for use with new detection devices. A direct comparison was made using a fiber optic biosensor that employs evanescent wave detection and an ELISA using avidin-biotin. The assays were developed for the detection of Ricinus communis agglutinin II, also known as ricin or RCA60. Detection limits between the two methods were comparable for ricin in phosphate buffered saline (PBS), however results in complex samples differed slightly. In PBS, sensitivity for ricin was 1 ng/ml using the fiber optic device and 500 pg/ml using the ELISA. The fiber optic sensor could not detect ricin directly in urine or serum spiked with 5 ng/ml ricin, however, the ELISA showed detection but at reduced levels to the PBS control.

  5. Biology and thermal requirements of Spodoptera cosmioides (Walk.) (Lepidoptera: Noctuidae)

    Energy Technology Data Exchange (ETDEWEB)

    Bavaresco, Alvimar [EPAGRI, Estacao Experimetal de Canoinhas, SC (Brazil)]. E-mail: alvimarbavaresco@bol.com.br; Garcia, Mauro S.; Gruetzmacher, Anderson D.; Foresti, Josemar; Ringenberg, Rudiney [Universidade Federal de Pelotas (UFPel), RS (Brazil). Dept. de Fitossanidade

    2002-01-15

    The biology of Spodoptera cosmioides (Walk.) was studied under different temperatures and its thermal requirements were determined, aiming to aid the rearing of this insect in the laboratory. Embryonic and post-embryonic periods were evaluated at seven different temperatures (14, 18, 22, 25, 28, 30 and 32 deg C) under environmental chamber conditions, with 14h photophase. The caterpillars were reared on an artificial diet containing white bean, soybean meal, yeast extract, wheat germ and powder milk as source of protein. The extent of the embryonic period decreased with the increase of temperature within the 14 deg C to 25 deg C temperature range, remaining constant between 28 deg C and 32 deg C. For the other phases (caterpillar, pre-pupa and pupa) an inverse relationship between temperature and duration was observed within the 14 deg C to 30 deg C temperature range, extending to 32 deg C for pupae. Duration of pupal phase for males was larger than for females resulting in asynchronous adult emergence. The temperature thresholds for the embryonic, larval, pre-pupal, pupal periods and total cycle were 9.34 deg C, 11.65 deg C, 9.65 deg C, 11.08 deg C and 11.23 deg C, with thermal constants of 62,73 degree-days (DD), 254.61DD, 33.42DD, 177.55DD and 525.11DD, respectively. Evaluating the pupal phase alone, the threshold temperatures were 11.25 deg C for males and 10.81deg C for females, with thermal constants of 188.26DD for males and 165.47DD for females. For total cycle, the threshold temperature and the thermal constant for males were 11.28 deg C and 535.85DD, whereas for females the same variables had values of 11.15 deg C and 513.17DD. So, the most adequate temperature for the development of S. cosmioides is within the range of 25 deg C and 28 deg C, where 9.6 to 11.7 generations of the insect can be annually obtained, in laboratory conditions. (author)

  6. Mercury speciation and total trace element determination of low-biomass biological samples.

    Science.gov (United States)

    Taylor, Vivien F; Jackson, Brian P; Chen, Celia Y

    2008-12-01

    Current approaches to mercury speciation and total trace element analysis require separate extraction/digestions of the sample. Ecologically important aquatic organisms--notably primary consumers such as zooplankton, polychaetes and amphipods--usually yield very low biomass for analysis, even with significant compositing of multiple organisms. Individual organisms in the lower aquatic food chains (mussels, snails, oysters, silversides, killifish) can also have very low sample mass, and analysis of whole single organisms is important to metal uptake studies. A method for the determination of both methyl Hg and total heavy metal concentrations (Zn, As, Se, Cd, Hg, Pb) in a single, low-mass sample of aquatic organisms was developed. Samples (2 to 50 mg) were spiked with enriched with (201)MeHg and (199)Hg, then leached in 4 M HNO(3) at 55 degrees C for extraction of MeHg. After 16 h, an aliquot (0.05 mL) was removed to determine mercury species (methyl and inorganic Hg) by isotope dilution gas chromatography inductively coupled plasma mass spectrometry (ICP-MS). The leachate was then acidified to 9 M HNO(3) and digested in a microwave at 150 degrees C for 10 min, and total metal concentrations were determined by collision cell ICP-MS. The method was validated by analyzing five biological certified reference materials. Average percent recoveries for Zn, As, Se, Cd, MeHg, Hg(total) and Pb were 99.9%, 103.5%, 100.4%, 103.3%, 101%, 97.7%, and 97.1%, respectively. The correlation between the sum of MeHg and inorganic Hg from the speciation analysis and total Hg by conventional digestion of the sample was determined for a large sample set of aquatic invertebrates (n = 285). Excellent agreement between the two measured values was achieved. This method is advantageous in situations where sample size is limited, and where correlations between Hg species and other metals are required in the same sample. The method also provides further validation of speciation data, by

  7. Fisheries Handbook of Engineering Requirements and Biological Criteria

    Science.gov (United States)

    1990-01-01

    Wilber , Charles G., "The biological aspects of water ety, 44:120-124. 1915. pollution." Charles C. Thomas. Springfield, Illinois. 1969. 26. Vernon, E.H...pp. 128- August, 1965. 141. Butterworths, London. 1964. 38. Wilber , Charles G., ’The biological aspects of water33. Goudey, R.F., "Chemical weed...April, Progressive Fish-Culturist, 30(2):67-75. April, 1968. 1963. 13. Dumas, Richard F., "Observations on yolk sac con- 27. Wolf, Ken , C.E. Dunbar, and

  8. Robotic, MEMS-based Multi Utility Sample Preparation Instrument for ISS Biological Workstation Project

    Data.gov (United States)

    National Aeronautics and Space Administration — This project will develop a multi-functional, automated sample preparation instrument for biological wet-lab workstations on the ISS. The instrument is based on a...

  9. Detection of heavy metals in biological samples through anodic stripping voltammetry

    OpenAIRE

    Buzea, Vlad; Florescu, Monica; Badea, Mihaela

    2012-01-01

    The toxicological aspects due to the presence of heavy metals in biological samples impose to have accurate and rapid methods for their detection. This paper is aimed to review approaches to anodic stripping voltammetry (ASV) determination of several heavy metals (lead, cadmium, copper, mercury, zinc) in biological matrices (blood, urine, saliva, tissue sample). Analytical performances (LOD, data linearity range, sensitivity) of the reviewed methods were presented for several electrochemical ...

  10. Jitter requirements of the sampling clock in software radio receivers

    NARCIS (Netherlands)

    Arkesteijn, Vincent J.; Klumperink, Eric A.M.; Nauta, Bram

    2006-01-01

    The effective number of bits of an analog-to-digital converter (ADC) is not only limited by the quantization step inaccuracy but also by sampling time uncertainty. According to a commonly used model, the error caused by timing jitter, integrated over the whole bandwidth, should not be bigger than th

  11. 40 CFR 141.22 - Turbidity sampling and analytical requirements.

    Science.gov (United States)

    2010-07-01

    ... the water distribution system at least once per day, for the purposes of making turbidity measurements... existed under the circumstances of this option. Turbidity measurements shall be made as directed in § 141... 40 Protection of Environment 22 2010-07-01 2010-07-01 false Turbidity sampling and...

  12. Determination of steroid hormones in biological and environmental samples using green microextraction techniques: an overview.

    Science.gov (United States)

    Aufartová, Jana; Mahugo-Santana, Cristina; Sosa-Ferrera, Zoraida; Santana-Rodríguez, José Juan; Nováková, Lucie; Solich, Petr

    2011-10-17

    Residues of steroid hormones have become a cause for concern because they can affect the biological activity of non-target organisms. Steroid hormones are a potential risk for wildlife and humans through the consumption of contaminated food or water. Their determination requires extraction and clean-up steps, prior to detection, to reach low concentration levels. In recent years, a great effort has been made to develop new analytical methodologies, such as microextraction techniques, that reduce environmental pollution. Researchers have modified old methods to incorporate procedures that use less-hazardous chemicals or that use smaller amounts of them. They are able to do direct analysis using miniaturised equipment and reduced amounts of solvents and wastes. These accomplishments are the main objectives of green analytical chemistry. In this overview, we focus on microextraction techniques for the determination of steroid hormones in biological (e.g., human urine, human serum, fish, shrimp and prawn tissue and milk) and environmental (e.g., wastewaters, surface waters, tap waters, river waters, sewage sludges, marine sediments and river sediments) samples. We comment on the most recent applications in sorptive-microextraction modes, such as solid phase microextraction (SPME) with molecularly imprinted polymers (MIPs), in-tube solid-phase microextraction (IT-SPME), stir-bar sorptive extraction (SBSE) and microextraction in packed sorbent (MEPS). We also describe liquid-phase microextraction (LPME) approaches reported in the literature that are applied to the determination of steroid hormones.

  13. 77 FR 30887 - Amendments to Sterility Test Requirements for Biological Products; Correction

    Science.gov (United States)

    2012-05-24

    ... Test Requirements for Biological Products; Correction AGENCY: Food and Drug Administration, HHS. ACTION... manufacturers of biological products greater flexibility, as appropriate, and encourages use of the most appropriate and state-of-the-art test methods for assuring the safety of biological products. The rule...

  14. Sample preparation strategies for food and biological samples prior to nanoparticle detection and imaging

    DEFF Research Database (Denmark)

    Larsen, Erik Huusfeldt; Löschner, Katrin

    2014-01-01

    fractionation (AFFF, or AF4) coupled on-line to various detectors including static and dynamic light scattering (LS), UV or fluorescence (FL) spectroscopies and ICP-MS have proven useful and powerful [1, 2, 3]. Furthermore, additional information obtained by an imaging method such as transmission electron...... microscopy (TEM) proved to be necessary for trouble shooting of results obtained from AFFF-LS-ICP-MS. Aqueous and enzymatic extraction strategies were tested for thorough sample preparation aiming at degrading the sample matrix and to liberate the AgNPs from chicken meat into liquid suspension. The resulting...

  15. Microfluidic devices for sample clean-up and screening of biological samples

    NARCIS (Netherlands)

    Tetala, K.K.R.

    2009-01-01

    Analytical chemistry plays an important role in the separation and identification of analytes from raw samples (e.g. plant extracts, blood), but the whole analytical process is tedious, difficult to automate and time consuming. To overcome these drawbacks, the concept of μTAS (miniaturized total ana

  16. Large Scale Computing and Storage Requirements for Biological and Environmental Research

    Energy Technology Data Exchange (ETDEWEB)

    DOE Office of Science, Biological and Environmental Research Program Office (BER),

    2009-09-30

    In May 2009, NERSC, DOE's Office of Advanced Scientific Computing Research (ASCR), and DOE's Office of Biological and Environmental Research (BER) held a workshop to characterize HPC requirements for BER-funded research over the subsequent three to five years. The workshop revealed several key points, in addition to achieving its goal of collecting and characterizing computing requirements. Chief among them: scientific progress in BER-funded research is limited by current allocations of computational resources. Additionally, growth in mission-critical computing -- combined with new requirements for collaborative data manipulation and analysis -- will demand ever increasing computing, storage, network, visualization, reliability and service richness from NERSC. This report expands upon these key points and adds others. It also presents a number of"case studies" as significant representative samples of the needs of science teams within BER. Workshop participants were asked to codify their requirements in this"case study" format, summarizing their science goals, methods of solution, current and 3-5 year computing requirements, and special software and support needs. Participants were also asked to describe their strategy for computing in the highly parallel,"multi-core" environment that is expected to dominate HPC architectures over the next few years.

  17. 49 CFR Appendix to Subpart G of... - Required Knowledge and Skills-Sample Guidelines

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 5 2010-10-01 2010-10-01 false Required Knowledge and Skills-Sample Guidelines... REGULATIONS COMMERCIAL DRIVER'S LICENSE STANDARDS; REQUIREMENTS AND PENALTIES Required Knowledge and Skills Pt. 383, Subpt. G, App. Appendix to Subpart G of Part 383—Required Knowledge and Skills—Sample...

  18. Procedures for cryogenic X-ray ptychographic imaging of biological samples

    Science.gov (United States)

    Yusuf, M.; Zhang, F.; Chen, B.; Bhartiya, A.; Cunnea, K.; Wagner, U.; Cacho-Nerin, F.; Schwenke, J.; Robinson, I. K.

    2017-01-01

    Biological sample-preparation procedures have been developed for imaging human chromosomes under cryogenic conditions. A new experimental setup, developed for imaging frozen samples using beamline I13 at Diamond Light Source, is described. This manuscript describes the equipment and experimental procedures as well as the authors’ first ptychographic reconstructions using X-rays.

  19. Procedures for cryogenic X-ray ptychographic imaging of biological samples.

    Science.gov (United States)

    Yusuf, M; Zhang, F; Chen, B; Bhartiya, A; Cunnea, K; Wagner, U; Cacho-Nerin, F; Schwenke, J; Robinson, I K

    2017-03-01

    Biological sample-preparation procedures have been developed for imaging human chromosomes under cryogenic conditions. A new experimental setup, developed for imaging frozen samples using beamline I13 at Diamond Light Source, is described. This manuscript describes the equipment and experimental procedures as well as the authors' first ptychographic reconstructions using X-rays.

  20. Procedures for cryogenic X-ray ptychographic imaging of biological samples

    Directory of Open Access Journals (Sweden)

    M. Yusuf

    2017-03-01

    Full Text Available Biological sample-preparation procedures have been developed for imaging human chromosomes under cryogenic conditions. A new experimental setup, developed for imaging frozen samples using beamline I13 at Diamond Light Source, is described. This manuscript describes the equipment and experimental procedures as well as the authors' first ptychographic reconstructions using X-rays.

  1. Study of complex matrix effect on solid phase microextraction for biological sample analysis.

    Science.gov (United States)

    Jiang, Ruifen; Xu, Jianqiao; Zhu, Fang; Luan, Tiangang; Zeng, Feng; Shen, Yong; Ouyang, Gangfeng

    2015-09-11

    Solid phase microextraction (SPME) has become a useful tool for in vivo monitoring the behavior of environmental organic pollutants in biological species due to its simplicity, relatively non-invasive, and cost-effective manner. However, the complex matrices in biological samples could significantly influence the extraction kinetic, and bias the quantification result. In this study, we investigated the effect of complex matrix on the extraction kinetic of SPME for biological sample analysis. Two sample matrices, phosphate-buffered saline (PBS) with bovine serum albumin (BSA) and agarose gel with BSA were used to simulate the biological fluid and tissue. Results showed that the addition of BSA significantly enhanced the mass transfer of organic compounds onto SPME fiber in both PBS buffer and gel sample. Enhancement factors ranging from 1.3 to 27, and 2.0 to 80 were found for all selected polyaromatic hydrocarbons (PAHs) in PBS buffer and agarose gel with BSA concentration of 0.1-5%, respectively. Then, an improved theoretical model was applied to quantify the observed enhancement effect, and the result showed that the predicted sampling time constant agreed well with the experimental one in complex matrix. Furthermore, a simplified equation was proposed for the real biological sample analysis.

  2. Determination of Cu, Zn, and Se in microvolumes of liquid biological samples

    Science.gov (United States)

    Shaban, H. A.; Shaltout, A. A.; Abdou, M.; Al Ashker, E. A.; Elgohary, M.

    2011-01-01

    Cu, Zn, and Se were successfully determined in a few microliters (<100 μl) of biological samples using discrete injection atomic absorption spectrometry. Different factors were investigated in order to obtain a biological sample volume which is valid for analysis. Among them are the effect of microsampling volume variations (starting from 40 to 200 μl), nebulization efficiency, detection limits, precision, and finally the calibration and sensitivity of the proposed method. It was found that 60 μl of the biological sample was adequate for the quantitative analysis with reasonable precision. The advantages of the proposed method are not only rapidity, simplicity, sensitivity, and good precision, but also, contrary to conventional flame atomic absorption spectrometry, the capability of analyzing microvolumes of samples.

  3. Non-destructive electron microscopy imaging and analysis of biological samples with graphene coating

    Science.gov (United States)

    Park, Jong Bo; Kim, Yong-Jin; Kim, Seong-Min; Yoo, Je Min; Kim, Youngsoo; Gorbachev, Roman; Barbolina, I. I.; Kim, Sang Jin; Kang, Sangmin; Yoon, Myung-Han; Cho, Sung-Pyo; Novoselov, Konstantin S.; Hong, Byung Hee

    2016-12-01

    In electron microscopy (EM), charging of non-conductive biological samples by focused electron beams hinders their high-resolution imaging. Gold or platinum coatings have been commonly used to prevent such sample charging, but it disables further quantitative and qualitative chemical analyses such as energy dispersive spectroscopy (EDS). Here we report that graphene-coating on biological samples enables non-destructive high-resolution imaging by EM as well as chemical analysis by EDS, utilizing graphene’s transparency to electron beams, high conductivity, outstanding mechanical strength and flexibility. We believe that the graphene-coated imaging and analysis would provide us a new opportunity to explore various biological phenomena unseen before due to the limitation in sample preparation and image resolution, which will broaden our understanding on the life mechanism of various living organisms.

  4. 9 CFR 113.51 - Requirements for primary cells used for production of biologics.

    Science.gov (United States)

    2010-01-01

    ... 9 Animals and Animal Products 1 2010-01-01 2010-01-01 false Requirements for primary cells used for production of biologics. 113.51 Section 113.51 Animals and Animal Products ANIMAL AND PLANT HEALTH... VECTORS STANDARD REQUIREMENTS Ingredient Requirements § 113.51 Requirements for primary cells used...

  5. 9 CFR 113.52 - Requirements for cell lines used for production of biologics.

    Science.gov (United States)

    2010-01-01

    ... 9 Animals and Animal Products 1 2010-01-01 2010-01-01 false Requirements for cell lines used for production of biologics. 113.52 Section 113.52 Animals and Animal Products ANIMAL AND PLANT HEALTH INSPECTION... STANDARD REQUIREMENTS Ingredient Requirements § 113.52 Requirements for cell lines used for production...

  6. Accuracy of whole-body plethysmography requires biological calibration

    DEFF Research Database (Denmark)

    Poorisrisak, Porntiva; Vrang, Carsten; Henriksen, Jorn Molgaard

    2009-01-01

    preschool children) were generated and were without significant difference between centers and independent of height, weight, age, and gender. We subsequently pooled these normative data (105 children) with our previous data from 121 healthy young children (overall mean sRaw, 1.27; SD, 0.25). CONCLUSION......: Control using biological standards revealed errors in the factory setting and highlights the need for developing methods for verification of resistance measures to assure accuracy. Normative data were subsequently generated. Importantly, other centers using such normative data should first consider proper...... of accuracy. Our aim was to determine the agreement of sRaw measurements in six centers and expand normative sRaw values for nonasthmatic children including these centers. METHOD: Identical hardware with different software versions was used at the six centers. Measurements followed a standard operating...

  7. Membrane materials for storing biological samples intended for comparative nanotoxicological testing

    Science.gov (United States)

    Metelkin, A.; Kuznetsov, D.; Kolesnikov, E.; Chuprunov, K.; Kondakov, S.; Osipov, A.; Samsonova, J.

    2015-11-01

    The study is aimed at identifying the samples of most promising membrane materials for storing dry specimens of biological fluids (Dried Blood Spots, DBS technology). Existing sampling systems using cellulose fiber filter paper have a number of drawbacks such as uneven distribution of the sample spot, dependence of the spot spreading area on the individual biosample properties, incomplete washing-off of the sample due to partially inconvertible sorption of blood components on cellulose fibers, etc. Samples of membrane materials based on cellulose, polymers and glass fiber with applied biosamples were studied using methods of scanning electron microscopy, FT-IR spectroscopy and surface-wetting measurement. It was discovered that cellulose-based membrane materials sorb components of biological fluids inside their structure, while membranes based on glass fiber display almost no interaction with the samples and biological fluid components dry to films in the membrane pores between the structural fibers. This characteristic, together with the fact that membrane materials based on glass fiber possess sufficient strength, high wetting properties and good storage capacity, attests them as promising material for dry samples of biological fluids storage systems.

  8. Chemometric and Statistical Analyses of ToF-SIMS Spectra of Increasingly Complex Biological Samples

    Energy Technology Data Exchange (ETDEWEB)

    Berman, E S; Wu, L; Fortson, S L; Nelson, D O; Kulp, K S; Wu, K J

    2007-10-24

    Characterizing and classifying molecular variation within biological samples is critical for determining fundamental mechanisms of biological processes that will lead to new insights including improved disease understanding. Towards these ends, time-of-flight secondary ion mass spectrometry (ToF-SIMS) was used to examine increasingly complex samples of biological relevance, including monosaccharide isomers, pure proteins, complex protein mixtures, and mouse embryo tissues. The complex mass spectral data sets produced were analyzed using five common statistical and chemometric multivariate analysis techniques: principal component analysis (PCA), linear discriminant analysis (LDA), partial least squares discriminant analysis (PLSDA), soft independent modeling of class analogy (SIMCA), and decision tree analysis by recursive partitioning. PCA was found to be a valuable first step in multivariate analysis, providing insight both into the relative groupings of samples and into the molecular basis for those groupings. For the monosaccharides, pure proteins and protein mixture samples, all of LDA, PLSDA, and SIMCA were found to produce excellent classification given a sufficient number of compound variables calculated. For the mouse embryo tissues, however, SIMCA did not produce as accurate a classification. The decision tree analysis was found to be the least successful for all the data sets, providing neither as accurate a classification nor chemical insight for any of the tested samples. Based on these results we conclude that as the complexity of the sample increases, so must the sophistication of the multivariate technique used to classify the samples. PCA is a preferred first step for understanding ToF-SIMS data that can be followed by either LDA or PLSDA for effective classification analysis. This study demonstrates the strength of ToF-SIMS combined with multivariate statistical and chemometric techniques to classify increasingly complex biological samples

  9. Correlation of mRNA and protein in complex biological samples.

    Science.gov (United States)

    Maier, Tobias; Güell, Marc; Serrano, Luis

    2009-12-17

    The correlation between mRNA and protein abundances in the cell has been reported to be notoriously poor. Recent technological advances in the quantitative analysis of mRNA and protein species in complex samples allow the detailed analysis of this pathway at the center of biological systems. We give an overview of available methods for the identification and quantification of free and ribosome-bound mRNA, protein abundances and individual protein turnover rates. We review available literature on the correlation of mRNA and protein abundances and discuss biological and technical parameters influencing the correlation of these central biological molecules.

  10. JURISPRUDENTIAL EXAMINATION REGARDING BIOLOGICAL SAMPLING IN THE CASE OF CONVICTED PERSONS

    Directory of Open Access Journals (Sweden)

    Gabriela\tNEMŢOI

    2015-12-01

    Full Text Available Objectives: The research devotes particular attention to the timing of biological sampling in the case of convicted persons. The main idea of the research is the factual situation regarding the criminal case law, which is not unified; problematic that prevents the formation of the National System of Judicial Genetic Data. Materials and Methods: The study focuses on evaluating the two opinions of jurisprudence on the implementation of the text of the law (Law no. 76/2008. Results: The carried research on different cases has shown that legal text is not mandatory, but its application is arbitrary, at the discretion of the court, but, nevertheless, the biological sampling in the case of convicted persons disregards the form for penalty. Conclusions: In the context of the creation of the National System of Judicial Genetic Data is a control condition on the typology of criminal profiling, we believe that biological sampling should be a priority to ensure safety of the individual.

  11. Recent developments in fatty acids profile determination in biological samples - a review

    Directory of Open Access Journals (Sweden)

    Tiuca Ioana

    2015-12-01

    Full Text Available The present paper is a literature review of the recent years dealing with the most important separation techniques of fatty acids in biological samples. Our aim was to make a synthesis of the analytical methods used, to note the most used ones, but also to mention other methods that are less utilized, which can have important advantages (such as less time consuming, greener reagents, etc.. Gas-chromatographic separation methods were described and compared to liquid chromatographic separations of fatty acids in different types of biological samples. In the same time, the importance of determining fatty acids profiles in biological samples was revealed, pointing out the possible implications in diagnostics of different types of disorders or remarking different profiles compared to healthy states.

  12. Energy-filtered transmission electron microscopy of biological samples on highly transparent carbon nanomembranes

    CERN Document Server

    Rhinow, Daniel; Weber, Nils-Eike; Beyer, André; Gölzhäuser, Armin; Kühlbrandt, Werner; Hampp, Norbert; Turchanin, Andrey; 10.1016/j.ultramic.2011.01.028

    2011-01-01

    Ultrathin carbon nanomembranes (CNM) comprising crosslinked biphenyl precursors have been tested as support films for energy-filtered transmission electron microscopy (EFTEM) of biological specimens. Due to their high transparency CNM are ideal substrates for electron energy loss spectroscopy (EELS) and electron spectroscopic imaging (ESI) of stained and unstained biological samples. Virtually background-free elemental maps of tobacco mosaic virus (TMV) and ferritin have been obtained from samples supported by ~ 1 nm thin CNM. Furthermore, we have tested conductive carbon nanomembranes (cCNM) comprising nanocrystalline graphene, obtained by thermal treatment of CNM, as supports for cryoEM of ice-embedded biological samples. We imaged ice-embedded TMV on cCNM and compared the results with images of ice-embedded TMV on conventional carbon film (CC), thus analyzing the gain in contrast for TMV on cCNM in a quantitative manner. In addition we have developed a method for the preparation of vitrified specimens, sus...

  13. Energy-filtered transmission electron microscopy of biological samples on highly transparent carbon nanomembranes

    Energy Technology Data Exchange (ETDEWEB)

    Rhinow, Daniel, E-mail: daniel.rhinow@biophys.mpg.de [Max-Planck-Institute of Biophysics, Department of Structural Biology, Max-von-Laue-Strasse 3, D-60439 Frankfurt (Germany); Bueenfeld, Matthias; Weber, Nils-Eike; Beyer, Andre; Goelzhaeuser, Armin [University of Bielefeld, Department of Physics, Universitaetsstrasse 25, D-33615 Bielefeld (Germany); Kuehlbrandt, Werner [Max-Planck-Institute of Biophysics, Department of Structural Biology, Max-von-Laue-Strasse 3, D-60439 Frankfurt (Germany); Hampp, Norbert [University of Marburg, Department of Chemistry, Hans-Meerwein-Strasse, D-35032 Marburg (Germany); Turchanin, Andrey [University of Bielefeld, Department of Physics, Universitaetsstrasse 25, D-33615 Bielefeld (Germany)

    2011-04-15

    Ultrathin carbon nanomembranes (CNM) comprising crosslinked biphenyl precursors have been tested as support films for energy-filtered transmission electron microscopy (EFTEM) of biological specimens. Due to their high transparency CNM are ideal substrates for electron energy loss spectroscopy (EELS) and electron spectroscopic imaging (ESI) of stained and unstained biological samples. Virtually background-free elemental maps of tobacco mosaic virus (TMV) and ferritin have been obtained from samples supported by {approx}1 nm thin CNM. Furthermore, we have tested conductive carbon nanomembranes (cCNM) comprising nanocrystalline graphene, obtained by thermal treatment of CNM, as supports for cryoEM of ice-embedded biological samples. We imaged ice-embedded TMV on cCNM and compared the results with images of ice-embedded TMV on conventional carbon film (CC), thus analyzing the gain in contrast for TMV on cCNM in a quantitative manner. In addition we have developed a method for the preparation of vitrified specimens, suspended over the holes of a conventional holey carbon film, while backed by ultrathin cCNM. -- Research highlights: {yields} We examine ultrathin carbon nanomembranes (CNM) as supports for biological TEM. {yields} CNM comprise crosslinked biphenyl precursors. {yields} CNM supports enable background-free elemental mapping of heavy and light elements. {yields} We perform cryoEM of ice-embedded biological samples on graphene-like conductive CNM.

  14. 21 CFR 111.465 - What requirements apply to holding reserve samples of dietary supplements?

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 2 2010-04-01 2010-04-01 false What requirements apply to holding reserve samples... Distributing § 111.465 What requirements apply to holding reserve samples of dietary supplements? (a) You must hold reserve samples of dietary supplements in a manner that protects against contamination...

  15. 21 CFR 111.83 - What are the requirements for reserve samples?

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 2 2010-04-01 2010-04-01 false What are the requirements for reserve samples? 111..., PACKAGING, LABELING, OR HOLDING OPERATIONS FOR DIETARY SUPPLEMENTS Requirement to Establish a Production and Process Control System § 111.83 What are the requirements for reserve samples? (a) You must collect...

  16. Determination of cadmium and lead in human biological samples by spectrometric techniques: a review.

    Science.gov (United States)

    Lemos, Valfredo Azevedo; de Carvalho, Anaildes Lago

    2010-12-01

    The analysis of human biological samples, such as blood, urine, nails, and hair, is generally used for the verification of human exposure to toxic metals. In this review, various spectrometric methods for the determination of cadmium and lead in biological samples are discussed and compared. Several spectrometric techniques are presented and discussed with respect to various characteristics such as sensitivity, selectivity, and cost. Special attention is drawn to the procedures for digestion prior to the determination of cadmium and lead in hair, nails, blood, and urine.

  17. Association of environmental toxic elements in biological samples of myocardial infarction patients at different stages.

    Science.gov (United States)

    Afridi, Hassan Imran; Kazi, Tasneem Gul; Kazi, Naveed; Kandhro, Ghulam Abbas; Baig, Jameel Ahmed; Jamali, Mohammad Khan; Arain, Mohammad Balal; Shah, Abdul Qadir; Shah, Faheem; Khan, Sumaira; Kolachi, Nida Fatima

    2011-06-01

    The exposure of toxic elements may directly or indirectly associate with different pathogenesis of heart diseases. In the present study, the association of arsenic (As), cadmium (Cd), cobalt (Co), lead (Pb), and nickel (Ni) in biological samples (whole blood and urine) and mortality from myocardial infarction (MI) patients at first, second, and third heart attacks was carried out. Both biological samples of 130 MI patients (77 male and 53 female), with ages ranging from 45 to 60 years, and 61 healthy persons (33 male and 28 female) of the same age group were collected. The elements in biological samples were assessed by electrothermal atomic absorption spectrophotometer, prior to microwave-assisted acid digestion. The validity of methodology was checked by the biological certified reference materials. During this study, 78% of 32 patients aged above 50 years, registered after third MI attack, died. In these subjects, the levels of As, Cd, Co, Ni, and Pb in blood samples were higher in MI patients as compared with referents (p < 0.05), while increased by 11.7%, 12.2%, 5.55%, and 7.2%, respectively, in the blood samples of those patients who tolerated the third MI attack (p = 0.12). The high level of understudied toxic elements may play a role in the mortality of MI patients.

  18. Photothermal method using a pyroelectric sensor for thermophysical characterization of agricultural and biological samples

    Science.gov (United States)

    Frandas, A.; Dadarlat, Dorin; Chirtoc, Mihai; Jalink, Henk; Bicanic, Dane D.; Paris, D.; Antoniow, Jean S.; Egee, Michel; Ungureanu, Costica

    1998-07-01

    The photopyroelectric method in different experimental configurations was used for thermophysical characterization of agricultural and biological samples. The study appears important due to the relation of thermal parameters to the quality of foodstuffs (connected to their preservation, storage and adulteration), migration profiles in biodegradable packages, and the mechanism of desiccation tolerance of seeds. Results are presented on the thermal parameters measurement and their dependence on temperature and water content for samples such as: honey, starch, seeds.

  19. Tomographic imaging of transparent biological samples using the pyramid phase microscope.

    Science.gov (United States)

    Iglesias, Ignacio

    2016-08-01

    We show how a pyramid phase microscope can be used to obtain tomographic information of the spatial variation of refractive index in biological samples using the Radon transform. A method that uses the information provided by the phase microscope for axial and lateral repositioning of the sample when it rotates is also described. Its application to the reconstruction of mouse embryos in the blastocyst stage is demonstrated.

  20. Robust identification of noncoding RNA from transcriptomes requires phylogenetically-informed sampling.

    Directory of Open Access Journals (Sweden)

    Stinus Lindgreen

    2014-10-01

    Full Text Available Noncoding RNAs are integral to a wide range of biological processes, including translation, gene regulation, host-pathogen interactions and environmental sensing. While genomics is now a mature field, our capacity to identify noncoding RNA elements in bacterial and archaeal genomes is hampered by the difficulty of de novo identification. The emergence of new technologies for characterizing transcriptome outputs, notably RNA-seq, are improving noncoding RNA identification and expression quantification. However, a major challenge is to robustly distinguish functional outputs from transcriptional noise. To establish whether annotation of existing transcriptome data has effectively captured all functional outputs, we analysed over 400 publicly available RNA-seq datasets spanning 37 different Archaea and Bacteria. Using comparative tools, we identify close to a thousand highly-expressed candidate noncoding RNAs. However, our analyses reveal that capacity to identify noncoding RNA outputs is strongly dependent on phylogenetic sampling. Surprisingly, and in stark contrast to protein-coding genes, the phylogenetic window for effective use of comparative methods is perversely narrow: aggregating public datasets only produced one phylogenetic cluster where these tools could be used to robustly separate unannotated noncoding RNAs from a null hypothesis of transcriptional noise. Our results show that for the full potential of transcriptomics data to be realized, a change in experimental design is paramount: effective transcriptomics requires phylogeny-aware sampling.

  1. Analysis of parallel optical sampling rate and ADC requirements in digital coherent receivers

    DEFF Research Database (Denmark)

    Lorences Riesgo, Abel; Galili, Michael; Peucheret, Christophe

    2012-01-01

    We comprehensively assess analog-to-digital converter requirements in coherent digital receiver schemes with parallel optical sampling. We determine the electronic requirements in accordance with the properties of the free running local oscillator.......We comprehensively assess analog-to-digital converter requirements in coherent digital receiver schemes with parallel optical sampling. We determine the electronic requirements in accordance with the properties of the free running local oscillator....

  2. Phytochemical analysis and biological evaluation of selected African propolis samples from Cameroon and Congo

    NARCIS (Netherlands)

    Papachroni, D.; Graikou, K.; Kosalec, I.; Damianakos, H.; Ingram, V.J.; Chinou, I.

    2015-01-01

    The objective of this study was the chemical analysis of four selected samples of African propolis (Congo and Cameroon) and their biological evaluation. Twenty-one secondary metabolites belonging to four different chemical groups were isolated from the 70% ethanolic extracts of propolis and their st

  3. A Method for Determining the Content of Glycoproteins in Biological Samples

    Directory of Open Access Journals (Sweden)

    Yang Gao

    2016-11-01

    Full Text Available The glycoprotein purified from the mycelium extract of Tremella fuciformis was marked with iodine through the iodine substitution reaction. The content of iodine, which is indicative of the amount of the marked tremella glycoprotein (ITG, was detected with Inductively coupled plasma mass spectrometry (ICP-MS. The method was found to be stable, sensitive, and accurate at detecting the content of iodine-substituted glycoprotein, and was used in the quantitative analysis of biological samples, including blood and organs. Different biological samples were collected from rats after oral administration of ITG, and were tested for iodine content by ICP-MS to calculate the amount of ITG in the samples. The results suggested that ICP-MS is a sensitive, stable, and accurate method for detection of iodinated glycoproteins in blood and organs.

  4. Electromembrane extraction as a rapid and selective miniaturized sample preparation technique for biological fluids

    DEFF Research Database (Denmark)

    Gjelstad, Astrid; Pedersen-Bjergaard, Stig; Seip, Knut Fredrik

    2015-01-01

    This special report discusses the sample preparation method electromembrane extraction, which was introduced in 2006 as a rapid and selective miniaturized extraction method. The extraction principle is based on isolation of charged analytes extracted from an aqueous sample, across a thin film...... of organic solvent, and into an aqueous receiver solution. The extraction is promoted by application of an electrical field, causing electrokinetic migration of the charged analytes. The method has shown to perform excellent clean-up and selectivity from complicated aqueous matrices like biological fluids....... Technical aspects of electromembrane extraction, important extraction parameters as well as a handful of examples of applications from different biological samples and bioanalytical areas are discussed in the paper....

  5. Lead Assessment in Biological Samples of Children with Different Gastrointestinal Disorders.

    Science.gov (United States)

    Shah, Faheem; Ullah, Naeem; Kazi, Tasneem Gul; Khan, Ajmal; Kandhro, Ghulam Abbas; Afridi, Hassan Imran; Arain, Mohammad Balal; Khan, Zahid; Farooq, Umar

    2016-01-01

    Lead (Pb) levels have been evaluated in the biological samples of children with different gastrointestinal disorders. Blood, scalp hair, and urine samples of children (of age 4-10 years) complaining about different gastrointestinal disorders were analyzed. For comparison, age matched healthy subjects were also included in this study. Biological samples were digested in a microwave oven prior to Pb determination by graphite furnace atomic absorption spectrometry. Significant differences in Pb profile were found between the diseased and referent children. Elevated Pb contents were observed in case of diseased children than WHO permissible limit, while normal results were obtained for healthy referents. The results were compared with those of healthy children having the same age, socioeconomic status, and residential areas.

  6. Nanocharacterization of soft biological samples in shear mode with quartz tuning fork probes.

    Science.gov (United States)

    Otero, Jorge; Gonzalez, Laura; Puig-Vidal, Manel

    2012-01-01

    Quartz tuning forks are extremely good resonators and their use is growing in scanning probe microscopy. Nevertheless, only a few studies on soft biological samples have been reported using these probes. In this work, we present the methodology to develop and use these nanosensors to properly work with biological samples. The working principles, fabrication and experimental setup are presented. The results in the nanocharacterization of different samples in different ambients are presented by using different working modes: amplitude modulation with and without the use of a Phase-Locked Loop (PLL) and frequency modulation. Pseudomonas aeruginosa bacteria are imaged in nitrogen using amplitude modulation. Microcontact printed antibodies are imaged in buffer using amplitude modulation with a PLL. Finally, metastatic cells are imaged in air using frequency modulation.

  7. Nanocharacterization of Soft Biological Samples in Shear Mode with Quartz Tuning Fork Probes

    Directory of Open Access Journals (Sweden)

    Manel Puig-Vidal

    2012-04-01

    Full Text Available Quartz tuning forks are extremely good resonators and their use is growing in scanning probe microscopy. Nevertheless, only a few studies on soft biological samples have been reported using these probes. In this work, we present the methodology to develop and use these nanosensors to properly work with biological samples. The working principles, fabrication and experimental setup are presented. The results in the nanocharacterization of different samples in different ambients are presented by using different working modes: amplitude modulation with and without the use of a Phase-Locked Loop (PLL and frequency modulation. Pseudomonas aeruginosa bacteria are imaged in nitrogen using amplitude modulation. Microcontact printed antibodies are imaged in buffer using amplitude modulation with a PLL. Finally, metastatic cells are imaged in air using frequency modulation.

  8. Toward greener analytical techniques for the absolute quantification of peptides in pharmaceutical and biological samples.

    Science.gov (United States)

    Van Eeckhaut, Ann; Mangelings, Debby

    2015-09-10

    Peptide-based biopharmaceuticals represent one of the fastest growing classes of new drug molecules. New reaction types included in the synthesis strategies to reduce the rapid metabolism of peptides, along with the availability of new formulation and delivery technologies, resulted in an increased marketing of peptide drug products. In this regard, the development of analytical methods for quantification of peptides in pharmaceutical and biological samples is of utmost importance. From the sample preparation step to their analysis by means of chromatographic or electrophoretic methods, many difficulties should be tackled to analyze them. Recent developments in analytical techniques emphasize more and more on the use of green analytical techniques. This review will discuss the progresses in and challenges observed during green analytical method development for the quantification of peptides in pharmaceutical and biological samples.

  9. Solid Phase Microextraction and Related Techniques for Drugs in Biological Samples

    Directory of Open Access Journals (Sweden)

    Mohammad Mahdi Moein

    2014-01-01

    Full Text Available In drug discovery and development, the quantification of drugs in biological samples is an important task for the determination of the physiological performance of the investigated drugs. After sampling, the next step in the analytical process is sample preparation. Because of the low concentration levels of drug in plasma and the variety of the metabolites, the selected extraction technique should be virtually exhaustive. Recent developments of sample handling techniques are directed, from one side, toward automatization and online coupling of sample preparation units. The primary objective of this review is to present the recent developments in microextraction sample preparation methods for analysis of drugs in biological fluids. Microextraction techniques allow for less consumption of solvent, reagents, and packing materials, and small sample volumes can be used. In this review the use of solid phase microextraction (SPME, microextraction in packed sorbent (MEPS, and stir-bar sorbtive extraction (SBSE in drug analysis will be discussed. In addition, the use of new sorbents such as monoliths and molecularly imprinted polymers will be presented.

  10. Inductively coupled plasma mass spectrometry in the analysis of biological samples and pharmaceutical drugs

    Science.gov (United States)

    Ossipov, K.; Seregina, I. F.; Bolshov, M. A.

    2016-04-01

    Inductively coupled plasma mass spectrometry (ICP-MS) is widely used in the analysis of biological samples (whole blood, serum, blood plasma, urine, tissues, etc.) and pharmaceutical drugs. The shortcomings of this method related to spectral and non-spectral interferences are manifested in full measure in determination of the target analytes in these complex samples strongly differing in composition. The spectral interferences are caused by similarity of masses of the target component and sample matrix components. Non-spectral interferences are related to the influence of sample matrix components on the physicochemical processes taking place during formation and transportation of liquid sample aerosols into the plasma, on the value and spatial distribution of plasma temperature and on the transmission of the ion beam from the interface to mass spectrometer detector. The review is devoted to analysis of different mechanisms of appearance of non-spectral interferences and to ways for their minimization or elimination. Special attention is paid to the techniques of biological sample preparation, which largely determine the mechanisms of the influence of sample composition on the results of element determination. The ways of lowering non-spectral interferences by instrumental parameter tuning and application of internal standards are considered. The bibliography includes 189 references.

  11. 40 CFR 258.53 - Ground-water sampling and analysis requirements.

    Science.gov (United States)

    2010-07-01

    ....53 Ground-water sampling and analysis requirements. (a) The ground-water monitoring program must... 40 Protection of Environment 24 2010-07-01 2010-07-01 false Ground-water sampling and analysis requirements. 258.53 Section 258.53 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED)...

  12. 40 CFR 257.23 - Ground-water sampling and analysis requirements.

    Science.gov (United States)

    2010-07-01

    ... and analysis requirements. (a) The ground-water monitoring program must include consistent sampling... 40 Protection of Environment 24 2010-07-01 2010-07-01 false Ground-water sampling and analysis requirements. 257.23 Section 257.23 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED)...

  13. Improved FIA-ABTS method for antioxidant capacity determination in different biological samples.

    Science.gov (United States)

    Bompadre, Stefano; Leone, Luciana; Politi, Alessia; Battino, Maurizio

    2004-08-01

    In order to evaluate the actual antioxidant features of foods, beverages and also plasma from patients, a number of assays have been developed in the last few years to determine the so called total antioxidant activity (TAA), intended as the cumulative capacity of a biological sample to scavenge free radicals. Most of the assays partially failed in obtaining a good reproducibility when using plasma because it is composed of a large number of substances, some of which are present at very high concentrations and possess masking features. For these reasons we have improved the widely known ABTS method by means of a FIA system where both temperature and dispersion of sample and reagent were strictly controlled. We found that temperature may be a critical aspect in the measurement of plasma TAA whilst its influence may be less important in the assay of non-complex biological samples. We demonstrated that also the reaction time may be critical, depending on the nature of the substance employed. Data confirmed the high TAA of a methylsalicylate-containing mouthrinse as well as the negligible TAA offered by the chlorhexidine containing one. White wines (Verdicchio) also displayed interesting TAA values. The improved method was useful to screen rapidly, without dilution, with very limited handling of the sample and with high repeatability the TAA of plasma in addition to chemical products, beverages and non-complex biological mixtures.

  14. Improved preparation of small biological samples for mercury analysis using cold vapor atomic absorption spectroscopy.

    Science.gov (United States)

    Adair, B M; Cobb, G P

    1999-05-01

    Concentrations of mercury in biological samples collected for environmental studies are often less than 0.1 microgram/g. Low mercury concentrations and small organ sizes in many wildlife species (approximately 0.1 g) increase the difficulty of mercury determination at environmentally relevant concentrations. We have developed a digestion technique to extract mercury from small (0.1 g), biological samples at these relevant concentrations. Mean recoveries (+/- standard error) from validation trials of mercury fortified tissue samples using cold vapor atomic absorption spectroscopy for analysis ranged from 102 +/- 4.3% (2.5 micrograms/L, n = 15) to 108 +/- 1.4% (25 micrograms/L, n = 15). Recoveries of inorganic mercury were 99 +/- 5 (n = 19) for quality assurance samples analyzed during environmental evaluations conducted during a 24 month period. This technique can be used to determine total mercury concentrations of 60 ng Hg/g sample. Samples can be analyzed in standard laboratories in a short time, at minimal cost. The technique is versatile and can be used to determine mercury concentrations in several different matrices, limiting the time and expense of method development and validation.

  15. Physicochemical characteristics and biological activities of seasonal atmospheric particulate matter sampling in two locations of Paris.

    Science.gov (United States)

    Baulig, Augustin; Poirault, Jean-Jacques; Ausset, Patrick; Schins, Roel; Shi, Tingming; Baralle, Delphine; Dorlhene, Pascal; Meyer, Martine; Lefevre, Roger; Baeza-Squiban, Armelle; Marano, Francelyne

    2004-11-15

    Fine particulate matter present in urban areas seems to be incriminated in respiratory disorders. The aim of this study was to relate physicochemical characteristics of PM2.5 (particulate matter collected with a 50% efficiency for particles with an aerodynamic diameter of 2.5 microm) to their biological activities toward a bronchial epithelial cell line 16-HBE. Two seasonal sampling campaigns of particles were realized, respectively, in a kerbside and an urban background station in Paris. Sampled-PM2.5 mainly consist of particles with a size below 1 microm and are mainly composed of soot as assessed by analytical scanning electron microscopy. The different PM2.5 samples contrasted in their PAH content, which was the highest in the kerbside station in winter, as well as in their metal content. Kerbside station samples were characterized by the highest Fe and Cu content, which appears correlated to their hydroxyl radical generating properties measured by electron paramagnetic resonance. Particles were compared by their capacity to induce cytotoxicity, intracellular ROS production, and proinflammatory cytokine release (GM-CSF and TNF-alpha). At a concentration of 10 microg/cm2, all samples induced peroxide production and cytokine release to the similar extent in the absence of cytotoxicity. In conclusion, whereas the PM2.5 samples differ by their PAH and metal composition, they induce the same biological responses likely either due to components bioavailability and/ or interactions between PM components.

  16. Elemental and isotopic imaging of biological samples using NanoSIMS.

    Science.gov (United States)

    Kilburn, Matt R; Clode, Peta L

    2014-01-01

    With its low detection limits and the ability to analyze most of the elements in the periodic table, secondary ion mass spectrometry (SIMS) represents one of the most versatile in situ analytical techniques available, and recent developments have resulted in significant advantages for the use of imaging mass spectrometry in biological and biomedical research. Increases in spatial resolution and sensitivity allow detailed interrogation of samples at relevant scales and chemical concentrations. Advances in dynamic SIMS, specifically with the advent of NanoSIMS, now allow the tracking of stable isotopes within biological systems at subcellular length scales, while static SIMS combines subcellular imaging with molecular identification. In this chapter, we present an introduction to the SIMS technique, with particular reference to NanoSIMS, and discuss its application in biological and biomedical research.

  17. Applications of PIXE to biological and biomedical samples at the university of gent

    Science.gov (United States)

    Maenhaut, W.; Vandenhaute, J.; Duflou, H.; De Reuck, J.

    1987-03-01

    The research on biological and biomedical samples, conducted at the University of Gent during the last 4-5 years and using PIXE as analytical technique, is presented. Our optimized sample/target preparation methods are described, and the accuracy and precision obtainable with them are discussed. Two comprehensive biological/biomedical research projects, initiated at Gent, are presented. The first aims at investigating possible trace element changes in tissues of experimental animals (rats) as a result of liver necrosis or cirrhosis, induced by intraperitoneal injection with CCl 4. The second project involves the determination of the regional distribution of trace elements in the human brain. Eight elements, i.e. K, Ca, Mn, Fe, Cu, Zn, Se and Rb, are being measured in up to 50 different regions of 12 normal brains, and in selected brain regions from patients with neurological disorders. Some of the results of the two projects are discussed.

  18. Electroanalytical Determination of Danofloxacin in Biological Samples Using Square Wave Voltammetry

    Directory of Open Access Journals (Sweden)

    Chirley Vanessa Boone

    2014-10-01

    Full Text Available The voltammetric behavior of danofloxacin (DFX has been studied, in aqueous solution, on a glassy carbon electrode using square wave voltammetry (SWV as electroanalytical technique. After optimization of the experimental conditions, DFX was analyzed in spiked biologic samples using a Britton-Robinson buffer with pH = 5.0 as the supporting electrolyte. Oxidation occurs at 0.98 V vs. Ag/AgCl in a two-electron process controlled by adsorption of the electrogenerated products on the electrode surface. A acceptable recovery was obtained for assay of spiked biologic samples, with value of 98.7% for the swine urine and 95.3 % for the bovine urine.

  19. Development of an improved immunoassay for detection of sorLA in cells and biological samples

    DEFF Research Database (Denmark)

    Andersen, Olav Michael; Thakurta, Ishita Guha; West, Mark J.

    , or traditional sandwich ELISA assays which are time consuming and less sensitive. Hence, the purpose of the present study is to develop a new assay called AlphaLISA which is fast and very sensitive, to measure sorLA in extremely small volumes of cells and biological samples. Methods: The Alpha......, which can be automated suitably for determination of sorLA in large sample batches. It also shows high recovery and signal to noise ratio. Conclusions: The results support the development of an improved method for measuring sorLA quantitatively, which could further prove as an important tool...

  20. Assessment of the differential linear coherent scattering coefficient of biological samples

    Science.gov (United States)

    Conceição, A. L. C.; Antoniassi, M.; Poletti, M. E.

    2010-07-01

    New differential linear coherent scattering coefficient, μ CS, data for four biological tissue types (fat pork, tendon chicken, adipose and fibroglandular human breast tissues) covering a large momentum transfer interval (0.07≤ q≤70.5 nm -1), resulted from combining WAXS and SAXS data, are presented in order to emphasize the need to update the default data-base by including the molecular interference and the large-scale arrangements effect. The results showed that the differential linear coherent scattering coefficient demonstrates influence of the large-scale arrangement, mainly due to collagen fibrils for tendon chicken and fibroglandular breast samples, and triacylglycerides for fat pork and adipose breast samples at low momentum transfer region. While, at high momentum transfer, the μ CS reflects effects of molecular interference related to water for tendon chicken and fibroglandular samples and, fatty acids for fat pork and adipose samples.

  1. Sampling designs matching species biology produce accurate and affordable abundance indices

    Directory of Open Access Journals (Sweden)

    Grant Harris

    2013-12-01

    Full Text Available Wildlife biologists often use grid-based designs to sample animals and generate abundance estimates. Although sampling in grids is theoretically sound, in application, the method can be logistically difficult and expensive when sampling elusive species inhabiting extensive areas. These factors make it challenging to sample animals and meet the statistical assumption of all individuals having an equal probability of capture. Violating this assumption biases results. Does an alternative exist? Perhaps by sampling only where resources attract animals (i.e., targeted sampling, it would provide accurate abundance estimates more efficiently and affordably. However, biases from this approach would also arise if individuals have an unequal probability of capture, especially if some failed to visit the sampling area. Since most biological programs are resource limited, and acquiring abundance data drives many conservation and management applications, it becomes imperative to identify economical and informative sampling designs. Therefore, we evaluated abundance estimates generated from grid and targeted sampling designs using simulations based on geographic positioning system (GPS data from 42 Alaskan brown bears (Ursus arctos. Migratory salmon drew brown bears from the wider landscape, concentrating them at anadromous streams. This provided a scenario for testing the targeted approach. Grid and targeted sampling varied by trap amount, location (traps placed randomly, systematically or by expert opinion, and traps stationary or moved between capture sessions. We began by identifying when to sample, and if bears had equal probability of capture. We compared abundance estimates against seven criteria: bias, precision, accuracy, effort, plus encounter rates, and probabilities of capture and recapture. One grid (49 km2 cells and one targeted configuration provided the most accurate results. Both placed traps by expert opinion and moved traps between capture

  2. Preconcentration and determination of heavy metals in water, sediment and biological samples

    Directory of Open Access Journals (Sweden)

    Shirkhanloo Hamid

    2011-01-01

    Full Text Available In this study, a simple, sensitive and accurate column preconcentration method was developed for the determination of Cd, Cu and Pb ions in river water, urine and sediment samples by flame atomic absorption spectrometry. The procedure is based on the retention of the analytes on a mixed cellulose ester membrane (MCEM column from buffered sample solutions and then their elution from the column with nitric acid. Several parameters, such as pH of the sample solution, volume of the sample and eluent and flow rates of the sample were evaluated. The effects of diverse ions on the preconcentration were also investigated. The recoveries were >95 %. The developed method was applied to the determination of trace metal ions in river water, urine and sediment samples, with satisfactory results. The 3δ detection limits for Cu, Pb and Cd were found to be 2, 3 and 0.2 μg dm−3, respectively. The presented procedure was successfully applied for determination of the copper, lead and cadmium contents in real samples, i.e., river water and biological samples.

  3. The Tip-Sample Interaction in Atomic Force Microscopy and its Implications for Biological Applications.

    Science.gov (United States)

    Baselt, David Randall

    This thesis describes the construction of an atomic force microscope and its application to the study of tip -sample interactions, primarily through the use of friction and hardness (elasticity) imaging. Part one describes the atomic force microscope, which consists of a scanned-cantilever stage (chapter 2); a versatile digital signal processor-based control system with self-optimizing feedback, lock-in amplifier emulation (for hardness imaging), and macro programmability (chapter 3); and image processing software (chapter 4). Part two describes a number of results that have helped to characterize the tip-sample interaction and the contact imaging modes used for its study. Meniscus forces act laterally as well as normally, and that they vary with position (chapter 5). Friction measurements couple with scanner position and feedback, and the meniscus effects friction images (chapter 6). Sliding of the tip over the sample surface introduces slope-dependence into hardness measurements (chapter 7). Dull tips can create prominent topography artifacts even on very flat surfaces (chapter 8). In an investigation of collagen fibrils, AFM has revealed the characteristic 65 nm banding pattern, a second, minor banding pattern, and microfibrils that run along the fibril axis. The distribution of proteoglycans along the fibrils creates a characteristic pattern in friction images. Although imaging in water reduces interaction forces, water can also make biological samples more sensitive to force. However, for robust biological samples imaged in air, tip shape presents a greater obstacle than tip -sample interaction forces to obtaining high-resolution images. Tip contamination increases tip-sample friction and can occasionally improve resolution (chapter 9). For a separate project I have designed a general -purpose nearfield scanning optical microscope (chapter 10).

  4. Potentiometric detection in UPLC as an easy alternative to determine cocaine in biological samples.

    Science.gov (United States)

    Daems, Devin; van Nuijs, Alexander L N; Covaci, Adrian; Hamidi-Asl, Ezat; Van Camp, Guy; Nagels, Luc J

    2015-07-01

    The analytical methods which are often used for the determination of cocaine in complex biological matrices are a prescreening immunoassay and confirmation by chromatography combined with mass spectrometry. We suggest an ultra-high-pressure liquid chromatography combined with a potentiometric detector, as a fast and practical method to detect and quantify cocaine in biological samples. An adsorption/desorption model was used to investigate the usefulness of the potentiometric detector to determine cocaine in complex matrices. Detection limits of 6.3 ng mL(-1) were obtained in plasma and urine, which is below the maximum residue limit (MRL) of 25 ng mL(-1). A set of seven plasma samples and 10 urine samples were classified identically by both methods as exceeding the MRL or being inferior to it. The results obtained with the UPLC/potentiometric detection method were compared with the results obtained with the UPLC/MS method for samples spiked with varying cocaine concentrations. The intraclass correlation coefficient was 0.997 for serum (n =7) and 0.977 for urine (n =8). As liquid chromatography is an established technique, and as potentiometry is very simple and cost-effective in terms of equipment, we believe that this method is potentially easy, inexpensive, fast and reliable.

  5. A review on determination of steroids in biological samples exploiting nanobio-electroanalytical methods.

    Science.gov (United States)

    Yadav, Saurabh K; Chandra, Pranjal; Goyal, Rajendra N; Shim, Yoon-Bo

    2013-01-31

    The applications of nanomaterial modified sensors, molecularly imprinting polymer based, aptamer based, and immunosensors have been described in the determination of steroids using electroanalytical techniques. After a brief description of the steroids and assays in biological fluids, the principles of electrochemical detection with the advantages and the limitations of the various sensors are presented. The nanomaterial modified sensors catalyze the oxidation/reduction of steroids and are suitable for sensing them in environmental samples and biological fluids. The determination of steroids based on their reduction has been found more useful in comparison to oxidation as the common metabolites present in the biological fluids do not undergo reduction in the usual potential window and hence, do not interfere in the determination. The sensors based on immunosensors and aptamers were found more sensitive and selective for steroid determination. Conducting polymer modified bio-sensors and microchip devices are suggested as possible future prospects for the ultra sensitive and simultaneous determination of steroids and their metabolites in various samples.

  6. High-resolution monochromator for iron nuclear resonance vibrational spectroscopy of biological samples

    Science.gov (United States)

    Yoda, Yoshitaka; Okada, Kyoko; Wang, Hongxin; Cramer, Stephen P.; Seto, Makoto

    2016-12-01

    A new high-resolution monochromator for 14.4-keV X-rays has been designed and developed for the Fe nuclear resonance vibrational spectroscopy of biological samples. In addition to high resolution, higher flux and stability are especially important for measuring biological samples, because of the very weak signals produced due to the low concentrations of Fe-57. A 24% increase in flux while maintaining a high resolution better than 0.9 meV is achieved in the calculation by adopting an asymmetric reflection of Ge, which is used as the first crystal of the three-bounce high-resolution monochromator. A 20% increase of the exit beam size is acceptable to our biological applications. The higher throughput of the new design has been experimentally verified. A fine rotation mechanics that combines a weak-link hinge with a piezoelectric actuator was used for controlling the photon energy of the monochromatic beam. The resulting stability is sufficient to preserve the intrinsic resolution.

  7. Measurement of Beryllium in Biological Samples by Accelerator Mass Spectrometry: Applications for Studying Chronic Beryllium Disease

    Energy Technology Data Exchange (ETDEWEB)

    Chiarappa-Zucca, M L; Finkel, R C; Martinelli, R E; McAninch, J E; Nelson, D O; Turtletaub, K W

    2004-04-15

    A method using accelerator mass spectrometry (AMS) has been developed for quantifying attomoles of beryllium (Be) in biological samples. This method provides the sensitivity to trace Be in biological samples at very low doses with the purpose of identifying the molecular targets involved in chronic beryllium disease. Proof of the method was tested by administering 0.001, 0.05, 0.5 and 5.0 {micro}g {sup 9}Be and {sup 10}Be by intraperitoneal injection to male mice and removing spleen, liver, femurs, blood, lung, and kidneys after 24 h exposure. These samples were prepared for AMS analysis by tissue digestion in nitric acid, followed by further organic oxidation with hydrogen peroxide and ammonium persulfate and lastly, precipitation of Be with ammonium hydroxide, and conversion to beryllium oxide at 800 C. The {sup 10}Be/{sup 9}Be ratio of the extracted beryllium oxide was measured by AMS and Be in the original sample was calculated. Results indicate that Be levels were dose-dependent in all tissues and the highest levels were measured in the spleen and liver. The measured {sup 10}Be/{sup 9}Be ratios spanned 4 orders of magnitude, from 10{sup -10} to 10{sup -14}, with a detection limit of 3.0 x 10{sup -14}, which is equivalent to 0.8 attomoles of {sup 10}Be. These results show that routine quantification of nanogram levels of Be in tissues is possible and that AMS is a sensitive method that can be used in biological studies to understand the molecular dosimetry of Be and mechanisms of toxicity.

  8. 21 CFR 610.68 - Exceptions or alternatives to labeling requirements for biological products held by the Strategic...

    Science.gov (United States)

    2010-04-01

    ... requirements for biological products held by the Strategic National Stockpile. 610.68 Section 610.68 Food and... GENERAL BIOLOGICAL PRODUCTS STANDARDS Labeling Standards § 610.68 Exceptions or alternatives to labeling requirements for biological products held by the Strategic National Stockpile. (a) The appropriate FDA...

  9. Spectrochemical analysis of powdered biological samples using transversely excited atmospheric carbon dioxide laser plasma excitation

    Science.gov (United States)

    Zivkovic, Sanja; Momcilovic, Milos; Staicu, Angela; Mutic, Jelena; Trtica, Milan; Savovic, Jelena

    2017-02-01

    The aim of this study was to develop a simple laser induced breakdown spectroscopy (LIBS) method for quantitative elemental analysis of powdered biological materials based on laboratory prepared calibration samples. The analysis was done using ungated single pulse LIBS in ambient air at atmospheric pressure. Transversely-Excited Atmospheric pressure (TEA) CO2 laser was used as an energy source for plasma generation on samples. The material used for the analysis was a blue-green alga Spirulina, widely used in food and pharmaceutical industries and also in a few biotechnological applications. To demonstrate the analytical potential of this particular LIBS system the obtained spectra were compared to the spectra obtained using a commercial LIBS system based on pulsed Nd:YAG laser. A single sample of known concentration was used to estimate detection limits for Ba, Ca, Fe, Mg, Mn, Si and Sr and compare detection power of these two LIBS systems. TEA CO2 laser based LIBS was also applied for quantitative analysis of the elements in powder Spirulina samples. Analytical curves for Ba, Fe, Mg, Mn and Sr were constructed using laboratory produced matrix-matched calibration samples. Inductively coupled plasma optical emission spectroscopy (ICP-OES) was used as the reference technique for elemental quantification, and reasonably well agreement between ICP and LIBS data was obtained. Results confirm that, in respect to its sensitivity and precision, TEA CO2 laser based LIBS can be successfully applied for quantitative analysis of macro and micro-elements in algal samples. The fact that nearly all classes of materials can be prepared as powders implies that the proposed method could be easily extended to a quantitative analysis of different kinds of materials, organic, biological or inorganic.

  10. Simple Sensitive Spectrophotometric Determination of Vanadium in Biological and Environmental Samples

    Directory of Open Access Journals (Sweden)

    B. Krishna Priya

    2006-01-01

    Full Text Available Novel, rapid, highly sensitive and selective spectrophotometric method for the determination of traces of vanadium (V in environmental and biological samples, pharmaceutical and steel samples was studied. The method is based on oxidation of 2,4- dinitro phenyl hydrazine(2,4-DNPH by vanadium (V followed by coupling reaction with N-(1-naphthalene-1-ylethane-1,2-diamine-dihydrochloride (NEDA in acidic medium to give red colored derivative or on oxidation of 4-Amino Pyridine by vanadium (V followed by coupling reaction with NEDA in basic medium to give pink colored derivative. The red colored derivative having an λmax 495 nm which is stable for 8 days and the pink colored derivative with 525 nm is stable for more than 7 days at 350C. Beer's law is obeyed for vanadium (V in the concentration range of 0.02 - 3.5 μg mL–1 (red derivative and 0.03 – 4.5 μg mL–1 (pink derivative at the wave length of maximum absorption. The optimum reaction conditions and other analytical parameters were investigated to enhance the sensitivity of the present method. The detailed study of various interferences made the method more selective. The proposed method was successfully applied to the analysis of vanadium in natural water samples, plant material, soil samples, synthetic mixtures, pharmaceutical samples and biological samples. The results obtained were agreed with the reported methods at the 95 % confidence level. The performance of proposed method was evaluated in terms of Student's t-test and Variance ratio f-test which indicates the significance of proposed method over reported method.

  11. Fiscal year 2002 tank characterization technical sampling basis and waste information requirements document

    Energy Technology Data Exchange (ETDEWEB)

    ADAMS, M.R.

    2001-08-08

    The Fiscal Year 2002 Tank Characterization Technical Sampling Basis and Waste Information Requirements Document (TSB-WIRD) has the following purposes: (1) To identify and integrate sampling and analysis needs for fiscal year (FY) 2002 and beyond. (2) To describe the overall drivers that require characterization information and to document their source. (3) To describe the process for identifying, prioritizing, and weighting issues that require characterization information to resolve. (4) To define the method for determining sampling priorities and to present the sampling priorities on a tank-by-tank basis. (5) To define how the characterization program is going to satisfy the drivers, close issues, and report progress. (6) To describe deliverables and acceptance criteria for characterization deliverables. Characterization information is required to maintain regulatory compliance, perform operations and maintenance, resolve safety issues, and prepare for disposal of waste. Commitments connected with these requirements are derived from the Hanford Facility Agreement and Consent Order (Ecology et al. 1996), also known as the Tri-Party Agreement (TPA), Hanford Facility Agreement and Consent Order Change Control Form M-44-97-03 (Ecology et al. 1997). and other requirement sources described in Section 3.0 of this document. The information contained in this TSB-WED reflects ongoing planning and current understanding of characterization information needs to resolve the issues listed in this TSB-WIRD. Since baseline requirements are subject to revision, the information contained herein may not exactly reflect baselines or sampling schedules published at a later date.

  12. Closer to the native state. Critical evaluation of cryo-techniques for Transmission Electron Microscopy: preparation of biological samples.

    Science.gov (United States)

    Mielanczyk, Lukasz; Matysiak, Natalia; Michalski, Marek; Buldak, Rafal; Wojnicz, Romuald

    2014-01-01

    Over the years Transmission Electron Microscopy (TEM) has evolved into a powerful technique for the structural analysis of cells and tissues at various levels of resolution. However, optimal sample preservation is required to achieve results consistent with reality. During the last few decades, conventional preparation methods have provided most of the knowledge about the ultrastructure of organelles, cells and tissues. Nevertheless, some artefacts can be introduced at all stagesofstandard electron microscopy preparation technique. Instead, rapid freezing techniques preserve biological specimens as close as possible to the native state. Our review focuses on different cryo-preparation approaches, starting from vitrification methods dependent on sample size. Afterwards, we discuss Cryo-Electron Microscopy Of VItreous Sections (CEMOVIS) and the main difficulties associated with this technique. Cryo-Focused Ion Beam (cryo-FIB) is described as a potential alternative for CEMOVIS. Another post-processing route for vitrified samples is freeze substitution and embedding in resin for structural analysis or immunolocalization analysis. Cryo-sectioning according to Tokuyasu is a technique dedicated to high efficiency immunogold labelling. Finally, we introduce hybrid techniques, which combine advantages of primary techniques originally dedicated to different approaches. Hybrid approaches permit to perform the study of difficult-to-fix samples and antigens or help optimize the sample preparation protocol for the integrated Laser and Electron Microscopy (iLEM) technique.

  13. H2S Analysis in Biological Samples Using Gas Chromatography with Sulfur Chemiluminescence Detection

    Science.gov (United States)

    Vitvitsky, Victor; Banerjee, Ruma

    2015-01-01

    Hydrogen sulfide (H2S) is a metabolite and signaling molecule in biological tissues that regulates many physiological processes. Reliable and sensitive methods for H2S analysis are necessary for a better understanding of H2S biology and for the pharmacological modulation of H2S levels in vivo. In this chapter, we describe the use of gas chromatography coupled to sulfur chemiluminescence detection to measure the rates of H2S production and degradation by tissue homogenates at physiologically relevant concentrations of substrates. This method allows separation of H2S from other sulfur compounds and provides sensitivity of detection to ~15 pg (or 0.5 pmol) of H2S per injected sample. PMID:25725519

  14. Practical Guide to Using Cryoprotectants in Biological Sample Preparation at Cryogenic temperature for Electron Microscopic Studies

    Directory of Open Access Journals (Sweden)

    A-Reum Je

    2011-10-01

    Full Text Available Cryo-fixation enables the preservation of the fine structures of intracellular organelles in a condition that is as close to their native state as possible compared with chemical fixation and room temperature processing. Fixation is the initial step for biological sample preparation in electron microscopy. This step is critically important because the goals of electron microscopic observation are fundamentally dependent on well-preserved specimens resulting from this fixation. In the present work, key components of cryo-fixation, cryoprotectants, are tested with various cell types of interest. The results show that dextran can be easily adapted for use with animal cells and cyanobacteria, whereas 1-hexadecene is applicable to plant and yeast cells. The current report provides useful information on the preparation of cryo-fixed biological specimens using high pressure freezing and freeze-substitution aimed at electron microscopic observation.

  15. Probabilistic Requirements (Partial) Verification Methods Best Practices Improvement. Variables Acceptance Sampling Calculators: Empirical Testing. Volume 2

    Science.gov (United States)

    Johnson, Kenneth L.; White, K. Preston, Jr.

    2012-01-01

    The NASA Engineering and Safety Center was requested to improve on the Best Practices document produced for the NESC assessment, Verification of Probabilistic Requirements for the Constellation Program, by giving a recommended procedure for using acceptance sampling by variables techniques as an alternative to the potentially resource-intensive acceptance sampling by attributes method given in the document. In this paper, the results of empirical tests intended to assess the accuracy of acceptance sampling plan calculators implemented for six variable distributions are presented.

  16. Slow-spinning low-sideband HR-MAS NMR spectroscopy: delicate analysis of biological samples

    Science.gov (United States)

    Renault, Marie; Shintu, Laetitia; Piotto, Martial; Caldarelli, Stefano

    2013-11-01

    High-Resolution Magic-Angle Spinning (HR-MAS) NMR spectroscopy has become an extremely versatile analytical tool to study heterogeneous systems endowed with liquid-like dynamics. Spinning frequencies of several kHz are however required to obtain NMR spectra, devoid of spinning sidebands, with a resolution approaching that of purely isotropic liquid samples. An important limitation of the method is the large centrifugal forces that can damage the structure of the sample. In this communication, we show that optimizing the sample preparation, particularly avoiding air bubbles, and the geometry of the sample chamber of the HR-MAS rotor leads to high-quality low-sideband NMR spectra even at very moderate spinning frequencies, thus allowing the use of well-established solution-state NMR procedures for the characterization of small and highly dynamic molecules in the most fragile samples, such as live cells and intact tissues.

  17. Applications of a DAD-HPLC method for determination of loratadine on biological samples

    Directory of Open Access Journals (Sweden)

    Pavalache Georgeta

    2015-06-01

    Full Text Available The aim of research is to assess the active substance by a HPLC method for the separation and quantitative determination of loratadine. The method has been developed and validated on the standard solutions, in previous research. The current study was undertaken to present the results obtained from loratadine determination in biological samples (human serum, urine and breast milk. These results may be applicable on patients with different physiological conditions (aging, pregnancy or recently giving birth, etc. and pathological conditions which may interfere with the metabolism of loratadine. The used HPLC method detected loratadine concentrations in human serum samples, respectively urine samples, at 2 hours after drug administration. The method detected traces of loratadine which passed into breast milk, as well. Data were statistically interpreted using MED CALC 10.2 software. These results show that the applied method can be used for quantitative analysis of loratadine in biological fluids (all permissible limits of quality specifications being in the range 95- 105%.

  18. 3D nanoscale imaging of biological samples with laboratory-based soft X-ray sources

    Science.gov (United States)

    Dehlinger, Aurélie; Blechschmidt, Anne; Grötzsch, Daniel; Jung, Robert; Kanngießer, Birgit; Seim, Christian; Stiel, Holger

    2015-09-01

    In microscopy, where the theoretical resolution limit depends on the wavelength of the probing light, radiation in the soft X-ray regime can be used to analyze samples that cannot be resolved with visible light microscopes. In the case of soft X-ray microscopy in the water-window, the energy range of the radiation lies between the absorption edges of carbon (at 284 eV, 4.36 nm) and oxygen (543 eV, 2.34 nm). As a result, carbon-based structures, such as biological samples, posses a strong absorption, whereas e.g. water is more transparent to this radiation. Microscopy in the water-window, therefore, allows the structural investigation of aqueous samples with resolutions of a few tens of nanometers and a penetration depth of up to 10μm. The development of highly brilliant laser-produced plasma-sources has enabled the transfer of Xray microscopy, that was formerly bound to synchrotron sources, to the laboratory, which opens the access of this method to a broader scientific community. The Laboratory Transmission X-ray Microscope at the Berlin Laboratory for innovative X-ray technologies (BLiX) runs with a laser produced nitrogen plasma that emits radiation in the soft X-ray regime. The mentioned high penetration depth can be exploited to analyze biological samples in their natural state and with several projection angles. The obtained tomogram is the key to a more precise and global analysis of samples originating from various fields of life science.

  19. The correlation of arsenic levels in drinking water with the biological samples of skin disorders

    Energy Technology Data Exchange (ETDEWEB)

    Kazi, Tasneem Gul [Center of Excellence in Analytical Chemistry, University of Sindh, Jamshoro 76080 (Pakistan)], E-mail: tgkazi@yahoo.com; Arain, Muhammad Balal [Center of Excellence in Analytical Chemistry, University of Sindh, Jamshoro 76080 (Pakistan)], E-mail: bilal_ku2004@yahoo.com; Baig, Jameel Ahmed [Center of Excellence in Analytical Chemistry, University of Sindh, Jamshoro 76080 (Pakistan)], E-mail: jab_mughal@yahoo.com; Jamali, Muhammad Khan [Center of Excellence in Analytical Chemistry, University of Sindh, Jamshoro 76080 (Pakistan)], E-mail: mkhanjamali@yahoo.com; Afridi, Hassan Imran [Center of Excellence in Analytical Chemistry, University of Sindh, Jamshoro 76080 (Pakistan)], E-mail: hassanimranafridi@yahoo.com; Jalbani, Nusrat [Pakistan Council for Scientific and Industrial Research, University Road Karachi-75280 (Pakistan)], E-mail: nusratjalbani_21@yahoo.com; Sarfraz, Raja Adil [Center of Excellence in Analytical Chemistry, University of Sindh, Jamshoro 76080 (Pakistan)], E-mail: rajaadilsarfraz@gmail.com; Shah, Abdul Qadir [Center of Excellence in Analytical Chemistry, University of Sindh, Jamshoro 76080 (Pakistan)], E-mail: aqshah07@yahoo.com; Niaz, Abdul [Center of Excellence in Analytical Chemistry, University of Sindh, Jamshoro 76080 (Pakistan)], E-mail: niazchemist2k6@yahoo.com

    2009-01-15

    Arsenic (As) poisoning has become a worldwide public health concern. The skin is quite sensitive to As and skin lesions are the most common and earliest nonmalignant effects associated to chronic As exposure. In 2005-2007, a survey was carried out on surface and groundwater arsenic contamination and relationships between As exposure via the drinking water and related adverse health effects (melanosis and keratosis) on villagers resides on the banks of Manchar lake, southern part of Sindh, Pakistan. We screened the population from arsenic-affected villages, 61 to 73% population were identified patients suffering from chronic arsenic toxicity. The effects of As toxicity via drinking water were estimated by biological samples (scalp hair and blood) of adults (males and females), have or have not skin problem (n = 187). The referent samples of both genders were also collected from the areas having low level of As (< 10 {mu}g/L) in drinking water (n = 121). Arsenic concentration in drinking water and biological samples were analyzed using electrothermal atomic absorption spectrometry. The range of arsenic concentrations in lake surface water was 35.2-158 {mu}g/L, which is 3-15 folds higher than World Health Organization [WHO, 2004. Guidelines for drinking-water quality third ed., WHO Geneva Switzerland.]. It was observed that As concentration in the scalp hair and blood samples were above the range of permissible values 0.034-0.319 {mu}g As/g for hair and < 0.5-4.2 {mu}g/L for blood. The linear regressions showed good correlations between arsenic concentrations in water versus hair and blood samples of exposed skin diseased subjects (R{sup 2} = 0.852 and 0.718) as compared to non-diseased subjects (R{sup 2} = 0.573 and 0.351), respectively.

  20. FY2001 Tank Characterization Technical Sampling Basis & Waste Information Requirements Document

    Energy Technology Data Exchange (ETDEWEB)

    ADAMS, M.R.

    2000-08-02

    The Fiscal Year 2001 Tank Characterization Technical Sampling Basis and Waste Information Requirements Document (TSB-WIRD) has the following purposes: (1) To identify and integrate sampling and analysis needs for fiscal year (FY) 2001 and beyond. (2) To describe the overall drivers that require characterization information and to document their source. (3) To describe the process for identifying, prioritizing, and weighting issues that require characterization information to resolve. (4) To define the method for determining sampling priorities and to present the sampling priorities on a tank-by-tank basis. (5) To define how the characterization program is going to satisfy the drivers, close issues, and report progress. (6)To describe deliverables and acceptance criteria for characterization deliverables.

  1. Evaluation of Botanical Reference Materials for the Determination of Vanadium in Biological Samples

    DEFF Research Database (Denmark)

    Heydorn, Kaj; Damsgaard, Else

    1982-01-01

    Three botanical reference materials prepared by the National Bureau of Standards have been studied by neutron activation analysis to evaluate their suitability with respect to the determination of vanadium in biological samples. Various decomposition methods were applied in connection with chemic....... A reference value of 1.15 mg/kg of this material is recommended, based on results from 3 different methods. All three materials are preferable to SRM 1571 Orchard Leaves, while Bowen's Kale remains the material of choice because of its lower concentration....

  2. Non-destructive high-resolution thermal imaging techniques to evaluate wildlife and delicate biological samples

    Energy Technology Data Exchange (ETDEWEB)

    Lavers, C; Franklin, P; Franklin, P; Plowman, A; Sayers, G; Bol, J; Shepard, D; Fields, D, E-mail: brnc-radarcomms1@nrta.mod.u [Sensors Team, Plymouth University at Britannia Royal Naval College, Dartmouth, Devon (United Kingdom) and Paignton Zoological Park, Paignton, Devon (United Kingdom); Thermal Wave Imaging, Inc., 845 Livernoise St, Ferndale, MI (United States); Buckfast Butterfly and Otter Sanctuary, Buckfast, Devon (United Kingdom)

    2009-07-01

    Thermal imaging cameras now allows routine monitoring of dangerous yet endangered wildlife in captivity. This study looks at the potential applications of radiometrically calibrated thermal data to wildlife, as well as providing parameters for future materials applications. We present a non-destructive active testing technique suitable for enhancing imagery contrast of thin or delicate biological specimens yielding improved thermal contrast at room temperature, for analysis of sample thermal properties. A broad spectrum of animals is studied with different textured surfaces, reflective and emissive properties in the infra red part of the electromagnetic spectrum. Some surface features offer biomimetic materials design opportunities.

  3. Selective extraction of proteins and other macromolecules from biological samples using molecular imprinted polymers.

    Science.gov (United States)

    Stevenson, Derek; El-Sharif, Hazim F; Reddy, Subrayal M

    2016-11-01

    The accurate determination of intact macromolecules in biological samples, such as blood, plasma, serum, urine, tissue and feces is a challenging problem. The increased interest in macromolecules both as candidate drugs and as biomarkers for diagnostic purposes means that new method development approaches are needed. This review charts developments in the use of molecularly imprinted polymers first for small-molecular-mass compounds then for proteins and other macromolecules. Examples of the development of molecularly imprinted polymers for macromolecules are highlighted. The two main application areas to date are sensors and separation science, particularly SPE. Examples include peptides and polypeptides, lysozyme, hemoglobin, ovalbumin, bovine serum albumin and viruses.

  4. Biological and biomedical (14)C-accelerator mass spectrometry and graphitization of carbonaceous samples.

    Science.gov (United States)

    Chung, Ill-Min; Kim, Seung-Hyun

    2013-06-21

    Accelerator mass spectrometry (AMS) is the ultimate technique for measuring rare isotopes in small samples. Biological and biomedical applications of (14)C-AMS (bio-(14)C-AMS) commenced in the early 1990s and are now widely used in many research fields including pharmacology, toxicology, food, and nutrition. For accurate, precise, and reproducible bio-(14)C-AMS analysis, the graphitization step in sample preparation is the most critical step. So, various sample preparation methods for a process called graphitization have been reported for specific applications. Catalytic graphitization using either a flame-sealed borosilicate tube or a septa-sealed vial is a popular sample preparation method for bio-(14)C-AMS. In this review, we introduce the AMS system, especially for bio-(14)C-AMS. In addition, we also review the graphitization method for bio-(14)C-AMS to promote further understanding and improvement of sample preparation for this technique. Examples of catalytic graphitization methods over the past two decades are described.

  5. Sample sizing of biological materials analyzed by energy dispersion X-ray fluorescence

    Energy Technology Data Exchange (ETDEWEB)

    Paiva, Jose D.S.; Franca, Elvis J.; Magalhaes, Marcelo R.L.; Almeida, Marcio E.S.; Hazin, Clovis A., E-mail: dan-paiva@hotmail.com, E-mail: ejfranca@cnen.gov.br, E-mail: marcelo_rlm@hotmail.com, E-mail: maensoal@yahoo.com.br, E-mail: chazin@cnen.gov.b [Centro Regional de Ciencias Nucleares do Nordeste (CRCN-NE/CNEN-PE), Recife, PE (Brazil)

    2013-07-01

    Analytical portions used in chemical analyses are usually less than 1g. Errors resulting from the sampling are barely evaluated, since this type of study is a time-consuming procedure, with high costs for the chemical analysis of large number of samples. The energy dispersion X-ray fluorescence - EDXRF is a non-destructive and fast analytical technique with the possibility of determining several chemical elements. Therefore, the aim of this study was to provide information on the minimum analytical portion for quantification of chemical elements in biological matrices using EDXRF. Three species were sampled in mangroves from the Pernambuco, Brazil. Tree leaves were washed with distilled water, oven-dried at 60 deg C and milled until 0.5 mm particle size. Ten test-portions of approximately 500 mg for each species were transferred to vials sealed with polypropylene film. The quality of the analytical procedure was evaluated from the reference materials IAEA V10 Hay Powder, SRM 2976 Apple Leaves. After energy calibration, all samples were analyzed under vacuum for 100 seconds for each group of chemical elements. The voltage used was 15 kV and 50 kV for chemical elements of atomic number lower than 22 and the others, respectively. For the best analytical conditions, EDXRF was capable of estimating the sample size uncertainty for further determination of chemical elements in leaves. (author)

  6. Proton Transmitting Energy Spectra and Transmission Electron Microscope Examinations of Biological Samples

    Science.gov (United States)

    Tan, Chun-yu; Xia, Yue-yuan; Zhang, Jian-hua; Mu, Yu-guang; Wang, Rui-jin; Liu, Ji-tian; Liu, Xiang-dong; Yu, Zeng-liang

    1999-02-01

    Transmission energy spectra of 530 keV H+ ion penetrating 140 μm thick seed coat of maize and fruit peel of grape with thickness of 100 μm were measured. The result indicates that these thick biological targets, as seen by the penetrating ions, are inhomogeneous, and there are open "channel like" paths along which the incident ions can transmit the targets easily. While most of the incident ions are stopped in the targets, some of the transmitting ions only lose a small fraction of their initial incident energy. The transmission energy spectra show a pure electronic stopping feature. Transmission electron microscope (TEM) micrographes taken from the samples of seed coat of maize and fruit peel of tomato with thickness of 60 μm indicate that 150 keV electron beam from the TEM can penetrate the thick samples to give very good images with clear contrasts.

  7. Analytical Methodologies for the Determination of Endocrine Disrupting Compounds in Biological and Environmental Samples

    Science.gov (United States)

    Sosa-Ferrera, Zoraida; Mahugo-Santana, Cristina; Santana-Rodríguez, José Juan

    2013-01-01

    Endocrine-disruptor compounds (EDCs) can mimic natural hormones and produce adverse effects in the endocrine functions by interacting with estrogen receptors. EDCs include both natural and synthetic chemicals, such as hormones, personal care products, surfactants, and flame retardants, among others. EDCs are characterised by their ubiquitous presence at trace-level concentrations and their wide diversity. Since the discovery of the adverse effects of these pollutants on wildlife and human health, analytical methods have been developed for their qualitative and quantitative determination. In particular, mass-based analytical methods show excellent sensitivity and precision for their quantification. This paper reviews recently published analytical methodologies for the sample preparation and for the determination of these compounds in different environmental and biological matrices by liquid chromatography coupled with mass spectrometry. The various sample preparation techniques are compared and discussed. In addition, recent developments and advances in this field are presented. PMID:23738329

  8. Analytical methodologies for the determination of endocrine disrupting compounds in biological and environmental samples.

    Science.gov (United States)

    Sosa-Ferrera, Zoraida; Mahugo-Santana, Cristina; Santana-Rodríguez, José Juan

    2013-01-01

    Endocrine-disruptor compounds (EDCs) can mimic natural hormones and produce adverse effects in the endocrine functions by interacting with estrogen receptors. EDCs include both natural and synthetic chemicals, such as hormones, personal care products, surfactants, and flame retardants, among others. EDCs are characterised by their ubiquitous presence at trace-level concentrations and their wide diversity. Since the discovery of the adverse effects of these pollutants on wildlife and human health, analytical methods have been developed for their qualitative and quantitative determination. In particular, mass-based analytical methods show excellent sensitivity and precision for their quantification. This paper reviews recently published analytical methodologies for the sample preparation and for the determination of these compounds in different environmental and biological matrices by liquid chromatography coupled with mass spectrometry. The various sample preparation techniques are compared and discussed. In addition, recent developments and advances in this field are presented.

  9. Phytochemical analysis and biological evaluation of selected African propolis samples from Cameroon and Congo.

    Science.gov (United States)

    Papachroni, Danai; Graikou, Konstantia; Kosalec, Ivan; Damianakos, Harilaos; Ingram, Verina; Chinou, Ioanna

    2015-01-01

    The objective of this study was the chemical analysis of four selected samples of African propolis (Congo and Cameroon) and their biological evaluation. Twenty-one secondary metabolites belonging to four different chemical groups were isolated from the 70% ethanolic extracts of propolis and their structures were elucidated on the basis of spectral evidence. Three triterpenes and two diprenyl-flavonoids were identified from Congo propolis, which has been investigated for the first time, while thirteen triterpenes, three diprenyl-flavonoids, two monoterpenic alcohols and one fatty acid ester have been identified from Cameroon propolis samples. To our knowledge, the identified diprenyl-flavonoids, as well as five of the isolated and determined triterpenes, are reported for the first time in propolis. Moreover, the total polyphenol content was estimated in all extracts and the antimicrobial activities of all four extracts were studied against six Gram-positive and -negative bacteria and three pathogenic fungi, showing an interesting antibacterial profile.

  10. A round-robin determination of boron in botanical and biological samples.

    Science.gov (United States)

    Downing, R G; Strong, P L

    1998-01-01

    The accurate determination of boron (B) at trace and ultratrace concentrations is an important step toward establishing the role of B in biological functions. However, low-level B concentrations are difficult to determine accurately, especially for many botanical and biological matrices. A round-robin study was conducted to assess analytical agreement for low-level B determinations. Ten experienced research groups from analytical laboratories extending across Europe, Asia, and the US participated in this study. These groups represent a cross-section of academic, commercial, and government facilities. The researchers employed both ion-coupled plasma and neutron techniques in the study. Results from this round-robin study indicate good agreement between participating laboratories at the mg/kg level, but at the lowest levels, microg/kg, only three laboratories participated, and agreement was poor. By encouraging discussion among scientists over these data, the secondary goal of this round-robin study is to stimulate continued improvement in analytical procedures and techniques for accurate low-level B determinations. Furthermore, it is intended to encourage the development of a variety of low-level (low mg/kg and microg/kg) B certified reference samples in biological and botanical matrices. The results from the round-robin analyses were compiled and are summarized in this article.

  11. 4D x-ray phase contrast tomography for repeatable motion of biological samples

    Science.gov (United States)

    Hoshino, Masato; Uesugi, Kentaro; Yagi, Naoto

    2016-09-01

    X-ray phase contrast tomography based on a grating interferometer was applied to fast and dynamic measurements of biological samples. To achieve this, the scanning procedure in the tomographic scan was improved. A triangle-shaped voltage signal from a waveform generator to a Piezo stage was used for the fast phase stepping in the grating interferometer. In addition, an optical fiber coupled x-ray scientific CMOS camera was used to achieve fast and highly efficient image acquisitions. These optimizations made it possible to perform an x-ray phase contrast tomographic measurement within an 8 min scan with density resolution of 2.4 mg/cm3. A maximum volume size of 13 × 13 × 6 mm3 was obtained with a single tomographic measurement with a voxel size of 6.5 μm. The scanning procedure using the triangle wave was applied to four-dimensional measurements in which highly sensitive three-dimensional x-ray imaging and a time-resolved dynamic measurement of biological samples were combined. A fresh tendon in the tail of a rat was measured under a uniaxial stretching and releasing condition. To maintain the freshness of the sample during four-dimensional phase contrast tomography, the temperature of the bathing liquid of the sample was kept below 10° using a simple cooling system. The time-resolved deformation of the tendon and each fascicle was measured with a temporal resolution of 5.7 Hz. Evaluations of cross-sectional area size, length of the axis, and mass density in the fascicle during a stretching process provided a basis for quantitative analysis of the deformation of tendon fascicle.

  12. Study on immunocapture-chemiluminescence assay of lipase activity in a biological sample.

    Science.gov (United States)

    Ichibangase, Tomoko; Hamabe, Chie; Ohba, Yoshihito; Kishikawa, Naoya; Nakashima, Kenichiro; Kayamori, Yuzo; Kang, Dongchon; Hamasaki, Naotaka; Kuroda, Naotaka

    2006-01-01

    A new approach for the determination of lipase (triacylglycerol lipase, EC.3.1.1.3) activity in a biological sample was investigated by combining an immunocapture technique with a chemiluminescence (CL) assay method in order to eliminate interference with CL detection. The proposed method consists of an immunocapture step to trap lipase and a subsequent step for CL detection of the activity of the captured lipase. The CL detection is based on the luminol-hydrogen peroxide (H(2)O(2))-horseradish peroxidase (HRP) reaction and utilizes a proenhancer substrate [a lauric acid ester of 2-(4-hydroxyphenyl)-4,5-diphenylimidazole (HDI)] which liberates an active enhancer, HDI, by enzymatic hydrolysis. A polyclonal antibody prepared with porcine pancreas lipase was used for the immunocapture. The proposed immunocapture-CL method effectively eliminated the interference with the CL reaction from biological components and enabled the determination of spiked porcine pancreas lipase activity in serum samples in the range 0.41-1.1 U(HDI) (1 U(HDI) corresponds to the amount which liberates 1 pmol HDI/min at 37 degrees C from the substrate). The method was further applied to the assay of the activity for human pancreas lipase in serum and the results showed good correlation (r = 0.871) with those by the conventional colorimetric method.

  13. [The biomonitoring of toxic substances in biological samples of general population].

    Science.gov (United States)

    Ibarluzea, Jesús; Aurrekoetxea, Juan José; Porta, Miquel; Sunyer, Jordi; Ballester, Ferran

    2016-11-01

    Many of the world's most developed countries have adopted biomonitoring of toxic substances in order to ascertain their levels in biological samples. These substances get into the body through different environmental exposures. Monitoring toxic substances in biological samples should allow us to ascertain their levels in vulnerable groups, assess their evolution over time, make comparisons with levels observed in other countries, identify groups at risk or with high toxic levels and promote research. The main objective of biomonitoring is to act as a policy design tool to facilitate the implementation of particular measures in various sectors: health, environmental, agricultural and livestock or food industry sectors. In Spain, information on levels of toxic substances of environmental origin is provided by specific studies on health effects from environmental sources, such as the INMA project (INfancia y Medio Ambiente [childhood and environment]). In addition, biomonitoring projects have been implemented in Catalonia and the Canary Islands, together with a national biomonitoring programme in the adult working population. However, further progress is needed to develop a system that covers the general population as well as subgroups at risk, which relies on the collaboration of the involved authorities and the participation of professionals from different sectors and citizen organisations interested in the relationship between health and the environment.

  14. Respondent driven sampling for HIV biological and behavioral surveillance in Latin America and the Caribbean.

    Science.gov (United States)

    Montealegre, Jane R; Johnston, Lisa G; Murrill, Christopher; Monterroso, Edgar

    2013-09-01

    Since 2005, respondent driven sampling (RDS) has been widely used for HIV biological and behavioral surveillance surveys (BBSS) in Latin America and the Caribbean (LAC). In this manuscript, we provide a focused review of RDS among hard-to-reach high-risk populations in LAC and describe their principal operational, design, and analytical considerations. We reviewed published and unpublished reports, protocols, and manuscripts for RDS studies conducted in LAC between January 1, 2005 and December 31, 2011. We abstracted key operational information and generated summary statistics across all studies. Between 2005 and 2011, 87 RDS studies were conducted in 15 countries in LAC (68 % in South America, 18 % in Mexico and Central America, and 14 % in the Caribbean). The target populations were primarily men who have sex with men (43 %), sex workers (29 %), and drug users (26 %). Study considerations included establishing clear eligibility criteria, measuring social network sizes, collecting specimens for biological testing, among others. Most of the reviewed studies are the first in their respective countries to collect data on hard-to-reach populations and the first attempt to use a probability-based sampling method. These RDS studies allowed researchers and public health practitioners in LAC to access hard-to-reach HIV high-risk populations and collect valuable data on the prevalence of HIV and other infections, as well as related risk behaviors.

  15. Label-free three-dimensional reconstruction of biological samples (Conference Presentation)

    Science.gov (United States)

    Aknoun, Sherazade; Bon, Pierre; Savatier, Julien; Monneret, Serge; Wattellier, Benoit F.

    2016-03-01

    We describe the use of spatially incoherent illumination combined with quantitative phase imaging (QPI) [1] to make tridimensional reconstruction of semi-transparent biological samples. Quantitative phase imaging is commonly used with coherent illumination for the relatively simple interpretation of the phase measurement. We propose to use spatially incoherent illumination which is known to increase lateral and axial resolution compared to classical coherent illumination. The goal is to image thick samples with intracellular resolution [2]. The 3D volume is imaged by axially scanning the sample with a quadri-wave lateral shearing interferometer used as a conventional camera while using spatially incoherent white-light illumination (native microscope halogen source) or NIR light. We use a non-modified inverted microscope equipped with a Z-axis piezo stage. A z-stack is recorded by objective translation along the optical axis. The main advantages of this approach are its easy implementation, compared to the other state-of-the-art diffraction tomographic setups, and its speed which makes even label-free 3D living sample imaging possible. A deconvolution algorithm is used to compensate for the loss in contrast due to spatially incoherent illumination. This makes the tomographic volume phase values quantitative. Hence refractive index could be recovered from the optical slices. We will present tomographic reconstruction of cells, thick fixed tissue of few tens of micrometers using white light, and the use of NIR light to reach deeper planes in the tissue.

  16. Label-free three dimensional reconstruction of biological samples (Conference Presentation)

    Science.gov (United States)

    Aknoun, Sherazade; Bon, Pierre; Savatier, Julien; Monneret, Serge; Wattellier, Benoit F.

    2016-03-01

    We describe the use of spatially incoherent illumination combined with quantitative phase imaging (QPI) [1] to make tridimensional reconstruction of semi-transparent biological samples. Quantitative phase imaging is commonly used with coherent illumination for the relatively simple interpretation of the phase measurement. We propose to use spatially incoherent illumination which is known to increase lateral and axial resolution compared to classical coherent illumination. The goal is to image thick samples with intracellular resolution [2]. The 3D volume is imaged by axially scanning the sample with a quadri-wave lateral shearing interferometer used as a conventional camera while using spatially incoherent white-light illumination (native microscope halogen source) or NIR light. We use a non-modified inverted microscope equipped with a Z-axis piezo stage. A z-stack is recorded by objective translation along the optical axis. The main advantages of this approach are its easy implementation, compared to the other state-of-the-art diffraction tomographic setups, and its speed which makes even label-free 3D living sample imaging possible. A deconvolution algorithm is used to compensate for the loss in contrast due to spatially incoherent illumination. This makes the tomographic volume phase values quantitative. Hence refractive index could be recovered from the optical slices. We will present tomographic reconstruction of cells, thick fixed tissue of few tens of micrometers using white light, and the use of NIR light to reach deeper planes in the tissue.

  17. Preparative divergent flow IEF without carrier ampholytes for separation of complex biological samples.

    Science.gov (United States)

    Stastna, Miroslava; Slais, Karel

    2010-01-01

    Efficient separation method is a crucial part of the process in which components of highly complex biological sample are identified and characterized. Based on the principles of recently newly established electrophoretic method called divergent flow IEF (DF IEF), we have tested the DF IEF instrument which is able to operate without the use of background carrier ampholytes. We have verified that during separation and focusing of sample consisting of high numbers of proteins (yeast lysate and wheat flour extract), the pH gradient of preparative DF IEF can be created by autofocusing of the sample components themselves without any addition of carrier ampholytes. In DF IEF, the proteins are separated, desalted and concentrated in one step. The fractions of yeast lysate sample, collected at the DF IEF output and subjected to gel IEF, contained the zones of proteins gradually covering the pI values from 3.7 to 8.5. In our experimental arrangement, the highest number of proteins has been found in fractions with pI values around 5.3 as detected by polyacrylamide gel IEF with CBB staining. During DF IEF, the selected protein bands have been concentrated up to 16.8-fold.

  18. An inexpensive and portable microvolumeter for rapid evaluation of biological samples.

    Science.gov (United States)

    Douglass, John K; Wcislo, William T

    2010-08-01

    We describe an improved microvolumeter (MVM) for rapidly measuring volumes of small biological samples, including live zooplankton, embryos, and small animals and organs. Portability and low cost make this instrument suitable for widespread use, including at remote field sites. Beginning with Archimedes' principle, which states that immersing an arbitrarily shaped sample in a fluid-filled container displaces an equivalent volume, we identified procedures that maximize measurement accuracy and repeatability across a broad range of absolute volumes. Crucial steps include matching the overall configuration to the size of the sample, using reflected light to monitor fluid levels precisely, and accounting for evaporation during measurements. The resulting precision is at least 100 times higher than in previous displacement-based methods. Volumes are obtained much faster than by traditional histological or confocal methods and without shrinkage artifacts due to fixation or dehydration. Calibrations using volume standards confirmed accurate measurements of volumes as small as 0.06 microL. We validated the feasibility of evaluating soft-tissue samples by comparing volumes of freshly dissected ant brains measured with the MVM and by confocal reconstruction.

  19. An enzyme-based DNA preparation method for application to forensic biological samples and degraded stains.

    Science.gov (United States)

    Lounsbury, Jenny A; Coult, Natalie; Miranian, Daniel C; Cronk, Stephen M; Haverstick, Doris M; Kinnon, Paul; Saul, David J; Landers, James P

    2012-09-01

    Extraction of DNA from forensic samples typically uses either an organic extraction protocol or solid phase extraction (SPE) and these methods generally involve numerous sample transfer, wash and centrifugation steps. Although SPE has been successfully adapted to the microdevice, it can be problematic because of lengthy load times and uneven packing of the solid phase. A closed-tube enzyme-based DNA preparation method has recently been developed which uses a neutral proteinase to lyse cells and degrade proteins and nucleases [14]. Following a 20 min incubation of the buccal or whole blood sample with this proteinase, DNA is polymerase chain reaction (PCR)-ready. This paper describes the optimization and quantitation of DNA yield using this method, and application to forensic biological samples, including UV- and heat-degraded whole blood samples on cotton or blue denim substrates. Results demonstrate that DNA yield can be increased from 1.42 (±0.21)ng/μL to 7.78 (±1.40)ng/μL by increasing the quantity of enzyme per reaction by 3-fold. Additionally, there is a linear relationship between the amount of starting cellular material added and the concentration of DNA in the solution, thereby allowing DNA yield estimations to be made. In addition, short tandem repeat (STR) profile results obtained using DNA prepared with the enzyme method were comparable to those obtained with a conventional SPE method, resulting in full STR profiles (16 of 16 loci) from liquid samples (buccal swab eluate and whole blood), dried buccal swabs and bloodstains and partial profiles from UV or heat-degraded bloodstains on cotton or blue denim substrates. Finally, the DNA preparation method is shown to be adaptable to glass or poly(methyl methacrylate) (PMMA) microdevices with little impact on STR peak height but providing a 20-fold reduction in incubation time (as little as 60 s), leading to a ≥1 h reduction in DNA preparation time.

  20. Exploring Earth's Atmospheric Biology using a Platform-Extensible Sampling Payload

    Science.gov (United States)

    Gentry, D.; Rothschild, L.

    2012-12-01

    The interactions between Earth's atmosphere and its biosphere, or aerobiology, remain a significant unknown. What few studies have been done conclusively show that Earth's atmosphere has a rich and dynamic microbial presence[Bowers et al., 2010]; that microbes suspended in air survive over long times (1-2 weeks)[Smith et al., 2010] and travel great distances (>5000 km)[Kellogg and Griffin, 2006]; that some airborne bacteria actively nucleate ice crystals, affecting meteorology[Delort et al., 2010]; and that the presence of microbes in the atmosphere has other planetary-scale effects[Delort et al., 2010]. Basic questions, however, such as the number of microbes present, their activity level and state, the different species present and their variance over time and space, remain largely unquantified. Compounding the significant physical and environmental challenges of reliable aerobiological sampling, collection and analysis of biological samples at altitudes above ~10-20 km has traditionally used ad hoc instrumentation and techniques, yielding primarily qualitative analytical results that lack a common basis for comparison[Bowers et al., 2010]. There is a strong need for broad-basis, repeatable, reliably comparable data about aerobiological basics. We describe here a high-altitude environmental and biological sampling project designed specifically to address these issues. The goal is a robust, reliable, re-usable sampling system, with open reproducibility and adaptability for multiple low-cost flight platforms (including ground-tethered systems, high-altitude balloons, and suborbital sounding rockets); by establishing a common modular payload structure for high-altitude sampling with appeal to a broad user base, we hope to encourage widespread collection of comparable aerobiological data. We are on our third prototype iteration, with demonstrated function of two sample capture modules, a support backbone (tracking, data logging, event response, etc.), a simple ground

  1. Investigation of resins suitable for the preparation of biological sample for 3-D electron microscopy.

    Science.gov (United States)

    Kizilyaprak, Caroline; Longo, Giovanni; Daraspe, Jean; Humbel, Bruno M

    2015-02-01

    In the last two decades, the third-dimension has become a focus of attention in electron microscopy to better understand the interactions within subcellular compartments. Initially, transmission electron tomography (TEM tomography) was introduced to image the cell volume in semi-thin sections (∼ 500 nm). With the introduction of the focused ion beam scanning electron microscope, a new tool, FIB-SEM tomography, became available to image much larger volumes. During TEM tomography and FIB-SEM tomography, the resin section is exposed to a high electron/ion dose such that the stability of the resin embedded biological sample becomes an important issue. The shrinkage of a resin section in each dimension, especially in depth, is a well-known phenomenon. To ensure the dimensional integrity of the final volume of the cell, it is important to assess the properties of the different resins and determine the formulation which has the best stability in the electron/ion beam. Here, eight different resin formulations were examined. The effects of radiation damage were evaluated after different times of TEM irradiation. To get additional information on mass-loss and the physical properties of the resins (stiffness and adhesion), the topography of the irradiated areas was analysed with atomic force microscopy (AFM). Further, the behaviour of the resins was analysed after ion milling of the surface of the sample with different ion currents. In conclusion, two resin formulations, Hard Plus and the mixture of Durcupan/Epon, emerged that were considerably less affected and reasonably stable in the electron/ion beam and thus suitable for the 3-D investigation of biological samples.

  2. Some Physical, Chemical, and Biological Parameters of Samples of Scleractinium Coral Aquaculture Skeleton Used for Reconstruction/Engineering of the Bone Tissue.

    Science.gov (United States)

    Popov, A A; Sergeeva, N S; Britaev, T A; Komlev, V S; Sviridova, I K; Kirsanova, V A; Akhmedova, S A; Dgebuadze, P Yu; Teterina, A Yu; Kuvshinova, E A; Schanskii, Ya D

    2015-08-01

    Physical and chemical (phase and chemical composition, dynamics of resorption, and strength properties), and biological (cytological compatibility and scaffold properties of the surface) properties of samples of scleractinium coral skeletons from aquacultures of three types and corresponding samples of natural coral skeletons (Pocillopora verrucosa, Acropora formosa, and Acropora nobilis) were studied. Samples of scleractinium coral aquaculture skeleton of A. nobilis, A. formosa, and P. verrucosa met the requirements (all study parameters) to materials for osteoplasty and 3D-scaffolds for engineering of bone tissue.

  3. A combined method for correlative 3D imaging of biological samples from macro to nano scale

    Science.gov (United States)

    Kellner, Manuela; Heidrich, Marko; Lorbeer, Raoul-Amadeus; Antonopoulos, Georgios C.; Knudsen, Lars; Wrede, Christoph; Izykowski, Nicole; Grothausmann, Roman; Jonigk, Danny; Ochs, Matthias; Ripken, Tammo; Kühnel, Mark P.; Meyer, Heiko

    2016-10-01

    Correlative analysis requires examination of a specimen from macro to nano scale as well as applicability of analytical methods ranging from morphological to molecular. Accomplishing this with one and the same sample is laborious at best, due to deformation and biodegradation during measurements or intermediary preparation steps. Furthermore, data alignment using differing imaging techniques turns out to be a complex task, which considerably complicates the interconnection of results. We present correlative imaging of the accessory rat lung lobe by combining a modified Scanning Laser Optical Tomography (SLOT) setup with a specially developed sample preparation method (CRISTAL). CRISTAL is a resin-based embedding method that optically clears the specimen while allowing sectioning and preventing degradation. We applied and correlated SLOT with Multi Photon Microscopy, histological and immunofluorescence analysis as well as Transmission Electron Microscopy, all in the same sample. Thus, combining CRISTAL with SLOT enables the correlative utilization of a vast variety of imaging techniques.

  4. Estimation of the fraction of biologically active methyl tert-butyl ether degraders in a heterogeneous biomass sample

    DEFF Research Database (Denmark)

    Waul, Christopher Kevin; Arvin, Erik; Schmidt, Jens Ejbye

    2008-01-01

    The fraction of biologically active methyl tert-butyl ether degraders in reactors is just as important for prediction of removal rates as knowledge of the kinetic parameters. The fraction of biologically active methyl tert-butyl ether degraders in a heterogeneous biomass sample, taken from a packed...

  5. Molecular dynamics simulations of biological membranes and membrane proteins using enhanced conformational sampling algorithms.

    Science.gov (United States)

    Mori, Takaharu; Miyashita, Naoyuki; Im, Wonpil; Feig, Michael; Sugita, Yuji

    2016-07-01

    This paper reviews various enhanced conformational sampling methods and explicit/implicit solvent/membrane models, as well as their recent applications to the exploration of the structure and dynamics of membranes and membrane proteins. Molecular dynamics simulations have become an essential tool to investigate biological problems, and their success relies on proper molecular models together with efficient conformational sampling methods. The implicit representation of solvent/membrane environments is reasonable approximation to the explicit all-atom models, considering the balance between computational cost and simulation accuracy. Implicit models can be easily combined with replica-exchange molecular dynamics methods to explore a wider conformational space of a protein. Other molecular models and enhanced conformational sampling methods are also briefly discussed. As application examples, we introduce recent simulation studies of glycophorin A, phospholamban, amyloid precursor protein, and mixed lipid bilayers and discuss the accuracy and efficiency of each simulation model and method. This article is part of a Special Issue entitled: Membrane Proteins edited by J.C. Gumbart and Sergei Noskov.

  6. Troubleshooting digital macro photography for image acquisition and the analysis of biological samples.

    Science.gov (United States)

    Liepinsh, Edgars; Kuka, Janis; Dambrova, Maija

    2013-01-01

    For years, image acquisition and analysis have been an important part of life science experiments to ensure the adequate and reliable presentation of research results. Since the development of digital photography and digital planimetric methods for image analysis approximately 20 years ago, new equipment and technologies have emerged, which have increased the quality of image acquisition and analysis. Different techniques are available to measure the size of stained tissue samples in experimental animal models of disease; however, the most accurate method is digital macro photography with software that is based on planimetric analysis. In this study, we described the methodology for the preparation of infarcted rat heart and brain tissue samples before image acquisition, digital macro photography techniques and planimetric image analysis. These methods are useful in the macro photography of biological samples and subsequent image analysis. In addition, the techniques that are described in this study include the automated analysis of digital photographs to minimize user input and exclude the risk of researcher-generated errors or bias during image analysis.

  7. Ultrasensitive techniques for measurement of uranium in biological samples and the nephrotoxicity of uranium: Proceedings

    Energy Technology Data Exchange (ETDEWEB)

    Kathren, R.L.; Weber, J.R. (eds.)

    1988-04-01

    Edited transcripts are provided of two public meetings sponsored by the Division of Radiation Programs and Earth Sciences of the Nuclear Regulatory Commission, Occupational Radiation Protection Branch. The first meeting, held on December 3, 1985, included nine presentations covering ultrasensitive techniques for measurement of uranium in biological specimens. Topics included laser-spectrometric techniques for uranium bioassay, correlation of urinary uranium samples with air sampling results in industrial settings, delayed neutron counting, laser-kinetic phosphometry, isotope dilution mass spectrometry, resonance ionization spectroscopy, fission track analysis, laser-induced fluorescence, and costs of sampling and processing. The nine presentations of the second meeting dealt with the nephrotoxicity of uranium. Among the topics presented were the physiology of the kidney, the effects of heavy metals on the kidney, animal studies in uranium nephrotoxicity, comparisons of kidney histology in nine humans, renal effects in uranium mill workers, renal damage from different uranium isotopes, and Canadian studies on uranium toxicity. Discussions following the presentations are included in the edited transcripts. 30 refs., 9 figs., 9 tabs.

  8. Evaluation of cadmium, lead, nickel and zinc status in biological samples of smokers and nonsmokers hypertensive patients

    OpenAIRE

    H. I. Afridi; Kazi, T G; Kazi, N G; Jamali, M K; Arain, M B; Sirajuddin,; Baig, J. A.; Kandhro, G A; Wadhwa, S K; Shah, A Q

    2009-01-01

    The objective of this study was to evaluate the association between trace and toxic elements zinc (Zn), cadmium (Cd), nickel (Ni) and lead (Pb) in biological samples (scalp hair, blood and urine) of smoker and nonsmoker hypertensive patients (n=457), residents of Hyderabad, Pakistan. For the purpose of comparison, the biological samples of age-matched healthy controls were selected as referents. The concentrations of trace and toxic elements were measured by atomic absorption spectrophotomete...

  9. Monitoring prion protein expression in complex biological samples by SERS for diagnostic applications

    Energy Technology Data Exchange (ETDEWEB)

    Manno, D; Filippo, E; Fiore, R; Serra, A [Dipartimento di Scienza dei Materiali, Universita del Salento, Lecce (Italy); Urso, E; Rizzello, A; Maffia, M [Dipartimento di Scienze e Tecnologie Biologiche ed Ambientali, Universita del Salento, Lecce (Italy)

    2010-04-23

    Surface-enhanced Raman spectroscopy (SERS) allows a new insight into the analysis of cell physiology. In this work, the difficulty of producing suitable substrates that, besides permitting the amplification of the Raman signal, do not interact with the biological material causing alteration, has been overcome by a combined method of hydrothermal green synthesis and thermal annealing. The SERS analysis of the cell membrane has been performed with special attention to the cellular prion protein PrP{sup C}. In addition, SERS has also been used to reveal the prion protein-Cu(II) interaction in four different cell models (B104, SH-SY5Y, GN11, HeLa), expressing PrP{sup C} at different levels. A significant implication of the current work consists of the intriguing possibility of revealing and quantifying prion protein expression in complex biological samples by a cheap SERS-based method, replacing the expensive and time-consuming immuno-assay systems commonly employed.

  10. A data-independent acquisition workflow for qualitative screening of new psychoactive substances in biological samples.

    Science.gov (United States)

    Kinyua, Juliet; Negreira, Noelia; Ibáñez, María; Bijlsma, Lubertus; Hernández, Félix; Covaci, Adrian; van Nuijs, Alexander L N

    2015-11-01

    Identification of new psychoactive substances (NPS) is challenging. Developing targeted methods for their analysis can be difficult and costly due to their impermanence on the drug scene. Accurate-mass mass spectrometry (AMMS) using a quadrupole time-of-flight (QTOF) analyzer can be useful for wide-scope screening since it provides sensitive, full-spectrum MS data. Our article presents a qualitative screening workflow based on data-independent acquisition mode (all-ions MS/MS) on liquid chromatography (LC) coupled to QTOFMS for the detection and identification of NPS in biological matrices. The workflow combines and structures fundamentals of target and suspect screening data processing techniques in a structured algorithm. This allows the detection and tentative identification of NPS and their metabolites. We have applied the workflow to two actual case studies involving drug intoxications where we detected and confirmed the parent compounds ketamine, 25B-NBOMe, 25C-NBOMe, and several predicted phase I and II metabolites not previously reported in urine and serum samples. The screening workflow demonstrates the added value for the detection and identification of NPS in biological matrices.

  11. Trace Level Arsenic Quantification through Cloud Point Extraction: Application to Biological and Environmental Samples

    Directory of Open Access Journals (Sweden)

    Kempahanumakkagari Suresh Kumar

    2012-01-01

    Full Text Available A sensitive solvent-free extraction protocol for the quantification of arsenic at trace level has been described. It is based on the reaction of arsenic (V with molybdate in acidic medium in presence of antimony (III and ascorbic acid as a reducing agent to form a blue-colored arsenomolybdenum blue complex. The complex has been extracted into surfactant phase using Triton X-114, and its absorbance was measured at 690 nm. The detection limit, working range, and the relative standard deviation were found to be 1 ng mL−1, 10–200 ng mL−1, and 1.2%, respectively. The effect of common ions was studied, and the method has been applied to determine trace levels of As(III and As(V from a variety of samples like environmental, biological, and commercially procured chemicals.

  12. Determination of Sodium Cromoglycate by a New Kinetic Spectrophotometric Method in Biological Samples

    Directory of Open Access Journals (Sweden)

    Mohsen Keyvanfard

    2013-01-01

    Full Text Available A new kinetic spectrophotometric method is described for the determination of ultratrace amounts of sodium cromoglycate (SCG. The method based on catalytic action of SCG on the oxidation of amaranth with periodate in acidic and micellar medium. The reaction was monitored spectrophotometrically by measuring the decrease in absorbance of the amaranth at 518 nm, for the first 4 min from initiation of the reaction. Calibration curve was linear in the range of 4.0−36.0 ng mL−1 SCG. The limit of detection is 2.7 ng mL−1 SCG. The relative standard deviation (RSD for ten replicate analyses of 12, 20, and 28 ng mL−1 SCG was 0.40%, 0.32%, and 0.53%, respectively. The proposed method was used for the determination of SCG in biological samples.

  13. Selective spectrofluorimetric determination of zinc in biological samples by Flow Injection Analysis (FIA)

    Energy Technology Data Exchange (ETDEWEB)

    Fernandez, P.; Perez Conde, C.; Gutierrez, A.; Camara, C. (Universidad Complutense, Madrid (Spain). Dept. de Quimica Analitica)

    1992-03-01

    The automatization of a spectrofluorimetric method for the determination of zinc at trace level is described. It is based on the formation of the fluorescent complex Zn(II)-5,7-dibromo-8-quinolinol (Zn(II)-DBQ) followed by extraction into diethylether using flow injection analysis. The optimum fluorescent emission is reached in hexamethylenetetramine (H{sub 2}MTA{sup +}/HMTA) buffer pH 6.0. A membrane phase separator was used. The calibration graph is linear up to 1.5 {mu}g/ml of Zn(II). The proposed method (detection limit 3 ng/ml) is very selective and has been successfully applied to determine Zn(II) in biological samples, tap waters and various food items. (orig.).

  14. Determination of gadolinium-based MRI contrast agents in biological and environmental samples: A review

    Energy Technology Data Exchange (ETDEWEB)

    Telgmann, Lena [University of Münster, Institute of Inorganic and Analytical Chemistry, Münster (Germany); Sperling, Michael [University of Münster, Institute of Inorganic and Analytical Chemistry, Münster (Germany); European Virtual Institute for Speciation Analysis (EVISA), Münster (Germany); Karst, Uwe, E-mail: uk@uni-muenster.de [University of Münster, Institute of Inorganic and Analytical Chemistry, Münster (Germany)

    2013-02-18

    Highlights: ► All major methods for the analysis of Gd-based MRI contrast agents are discussed. ► Biological and environmental samples are covered. ► Pharmacokinetics and species transformation can be investigated. ► The figures of merit as limit of detection and analysis time are described. -- Abstract: The development of analytical methods and strategies to determine gadolinium and its complexes in biological and environmental matrices is evaluated in this review. Gadolinium (Gd) chelates are employed as contrast agents for magnetic resonance imaging (MRI) since the 1980s. In general they were considered as safe and well-tolerated, when in 2006, the disease nephrogenic systemic fibrosis (NSF) was connected to the administration of MRI contrast agents based on Gd. Pathogenesis and etiology of NSF are yet unclear and called for the development of several analytical methods to obtain elucidation in this field. Determination of Gd complex stability in vitro and in vivo, as well as the quantification of Gd in body fluids like blood and urine was carried out. Separation of the Gd chelates was achieved with high performance liquid chromatography (HPLC) and capillary electrophoresis (CE). For detection, various methods were employed, including UV–vis absorbance and fluorescence spectroscopy, electrospray ionization mass spectrometry (ESI-MS) and inductively coupled plasma mass spectrometry (ICP-MS). A second challenge for analysts was the discovery of high concentrations of anthropogenic Gd in surface waters draining populated areas. The source could soon be determined to be the increasing administration of Gd complexes during MRI examinations. Identification and quantification of the contrast agents was carried out in various surface and groundwater samples to determine the behavior and fate of the Gd chelates in the environment. The improvement of limits of detection (LOD) and limits of quantification (LOQ) was and still is the goal of past and ongoing

  15. Solid-phase extraction and liquid chromatographic quantitation of quinfamide in biological samples.

    Science.gov (United States)

    Morales, J M; Jung, C H; Alarcón, A; Barreda, A

    2000-09-15

    This paper describes a high-performance liquid chromatographic method for the assay of quinfamide and its main metabolite, 1-(dichloroacetyl)-1,2,3,4,-tetrahydro-6-quinolinol, in plasma, urine and feces. It requires 1 ml of biological fluid, an extraction using Sep-Pack cartridges and acetonitrile for drug elution. Analysis was performed on a CN column (5 microm) using water-acetonitrile-methanol (40:50:10) as a mobile phase at 269 nm. Results showed that the assay was linear in the range between 0.08 and 2.0 microg/ml. The limit of quantitation was 0.08 microg/ml. Maximum assay coefficient of variation was 14%. Recovery obtained in plasma, urine and feces ranged from 82% to 98%.

  16. 21 CFR 201.56 - Requirements on content and format of labeling for human prescription drug and biological products.

    Science.gov (United States)

    2010-04-01

    ... human prescription drug and biological products. 201.56 Section 201.56 Food and Drugs FOOD AND DRUG... human prescription drug and biological products. (a) General requirements. Prescription drug labeling... requirements in §§ 201.56(d) and 201.57. (1) The following categories of prescription drug products are...

  17. Application of ion mobility spectrometry for the determination of tramadol in biological samples

    Directory of Open Access Journals (Sweden)

    Ali Sheibani

    2014-12-01

    Full Text Available In this study, a simple and rapid ion mobility spectrometry (IMS method has been described for the determination of tramadol. The operating instrumental parameters that could influence IMS were investigated and optimized (temperature; injection: 220 and IMS cell: 190°C, flow rate; carrier: 300 and drift: 600 mL/minute, voltage; corona: 2300 and drift: 7000 V, pulse width: 100 μs. Under optimum conditions, the calibration curves were linear within two orders of magnitude with R2 ≥ 0.998 for the determination of tramadol in human plasma, saliva, serum, and urine samples. The limits of detection and the limits of quantitation were between 0.1 and 0.3 and 0.3 and 1 ng/mL, respectively. The relative standard deviations were between 7.5 and 8.8%. The recovery results (90–103.9% indicate that the proposed method can be applied for tramadol analysis in different biological samples.

  18. A new HPLC method for the direct analysis of triglycerides of dicarboxylic acids in biological samples.

    Science.gov (United States)

    Capristo, E; Mingrone, G; De Gaetano, A; Addolorato, G; Greco, A V; Gasbarrini, G

    1999-11-01

    Dicarboxylic acids (DA) are alternate lipid substrates recently proposed in parenteral nutrition. Two new derivatives of DA, a triglyceride of sebacic (TGC10) and one of dodecanedioic (TGC12) acid have been synthesised in order to reduce the amount of sodium given with the unesterified forms. The present paper describes a rapid and direct high-performance liquid chromatographic method (HPLC) for the analysis of these substances in both plasma and urine. Thirty-six male Wistar rats were rapidly injected with 64 mg of TGC10 or 53 mg of TGC12. The triglycerides and their products of hydrolysis were measured in plasma samples taken at different times. For the dose of 500 ng the intra-assay variations ranged from 6. 80+/-0.35% for TGC10 to 18.6+/-3.20% for TGC12 and the inter-assay variations were from 4.44+/-2.21% for TGC10 to 15.0+/-6.72% for TGC12. The detection limit for both triglycerides was 5 ng. This rapid and direct HPLC method could have practical implications in monitoring the concentration of both triglycerides and free forms of DA in biological samples of patients who might benefit from the administration of these substances during parenteral nutrition regimens.

  19. Synchrotron-based X-ray fluorescence, imaging and elemental mapping from biological samples

    Indian Academy of Sciences (India)

    D V Rao; M Swapna; R Cesareo; A Brunetti; T Akatsuka; T Yuasa; T Takeda; G E Gigante

    2011-02-01

    The present study utilized the new hard X-ray microspectroscopy beamline facility, X27A, available at NSLS, BNL, USA, for elemental mapping. This facility provided the primary beam in a small spot of the order of ∼ 10 m, for focussing. With this spatial resolution and high flux throughput, the synchrotron-based X-ray fluorescent intensities for Mn, Fe, Zn, Cr, Ti and Cu were measured using a liquid-nitrogen-cooled 13-element energy-dispersive high-purity germanium detector. The sample is scanned in a `step-and-repeat’ mode for fast elemental mapping measurements and generated elemental maps at 8, 10 and 12 keV, from a small animal shell (snail). The accumulated trace elements, from these biological samples, in small areas have been identified. Analysis of the small areas will be better suited to establish the physiology of metals in specific structures like small animal shell and the distribution of other elements.

  20. Synchrotron-based X-ray fluorescence imaging and elemental mapping from biological samples

    Energy Technology Data Exchange (ETDEWEB)

    D Rao; M Swapna; R Cesareo; A Brunetti; T Akatsuka; T Yuasa; T Takeda; G Gigante

    2011-12-31

    The present study utilized the new hard X-ray microspectroscopy beamline facility, X27A, available at NSLS, BNL, USA, for elemental mapping. This facility provided the primary beam in a small spot of the order of {approx}10 {mu}m, for focussing. With this spatial resolution and high flux throughput, the synchrotron-based X-ray fluorescent intensities for Mn, Fe, Zn, Cr, Ti and Cu were measured using a liquid-nitrogen-cooled 13-element energy-dispersive high-purity germanium detector. The sample is scanned in a 'step-and-repeat' mode for fast elemental mapping measurements and generated elemental maps at 8, 10 and 12 keV, from a small animal shell (snail). The accumulated trace elements, from these biological samples, in small areas have been identified. Analysis of the small areas will be better suited to establish the physiology of metals in specific structures like small animal shell and the distribution of other elements.

  1. Sample size requirements for indirect association studies of gene-environment interactions (G x E).

    Science.gov (United States)

    Hein, Rebecca; Beckmann, Lars; Chang-Claude, Jenny

    2008-04-01

    Association studies accounting for gene-environment interactions (G x E) may be useful for detecting genetic effects. Although current technology enables very dense marker spacing in genetic association studies, the true disease variants may not be genotyped. Thus, causal genes are searched for by indirect association using genetic markers in linkage disequilibrium (LD) with the true disease variants. Sample sizes needed to detect G x E effects in indirect case-control association studies depend on the true genetic main effects, disease allele frequencies, whether marker and disease allele frequencies match, LD between loci, main effects and prevalence of environmental exposures, and the magnitude of interactions. We explored variables influencing sample sizes needed to detect G x E, compared these sample sizes with those required to detect genetic marginal effects, and provide an algorithm for power and sample size estimations. Required sample sizes may be heavily inflated if LD between marker and disease loci decreases. More than 10,000 case-control pairs may be required to detect G x E. However, given weak true genetic main effects, moderate prevalence of environmental exposures, as well as strong interactions, G x E effects may be detected with smaller sample sizes than those needed for the detection of genetic marginal effects. Moreover, in this scenario, rare disease variants may only be detectable when G x E is included in the analyses. Thus, the analysis of G x E appears to be an attractive option for the detection of weak genetic main effects of rare variants that may not be detectable in the analysis of genetic marginal effects only.

  2. Copper, chromium, manganese, iron, nickel, and zinc levels in biological samples of diabetes mellitus patients.

    Science.gov (United States)

    Kazi, Tasneem Gul; Afridi, Hassan Imran; Kazi, Naveed; Jamali, Mohammad Khan; Arain, Mohammad Bilal; Jalbani, Nussarat; Kandhro, Ghulam Abbas

    2008-04-01

    There is accumulating evidence that the metabolism of several trace elements is altered in diabetes mellitus and that these nutrients might have specific roles in the pathogenesis and progress of this disease. The aim of present study was to compare the level of essential trace elements, chromium (Cr), copper (Cu), iron (Fe), manganese (Mn), nickel (Ni), and zinc (Zn) in biological samples (whole blood, urine, and scalp hair) of patients who have diabetes mellitus type 2 (n = 257), with those of nondiabetic control subjects (n = 166), age ranged (45-75) of both genders. The element concentrations were measured by means of an atomic absorption spectrophotometer after microwave-induced acid digestion. The validity and accuracy was checked by conventional wet-acid-digestion method and using certified reference materials. The overall recoveries of all elements were found in the range of (97.60-99.49%) of certified values. The results of this study showed that the mean values of Zn, Mn, and Cr were significantly reduced in blood and scalp-hair samples of diabetic patients as compared to control subjects of both genders (p < 0.001). The urinary levels of these elements were found to be higher in the diabetic patients than in the age-matched healthy controls. In contrast, high mean values of Cu and Fe were detected in scalp hair and blood from patients versus the nondiabetic subjects, but the differences found in blood samples was not significant (p < 0.05). These results are consistent with those obtained in other studies, confirming that deficiency and efficiency of some essential trace metals may play a role in the development of diabetes mellitus.

  3. Evaluation of arsenic, cobalt, copper and manganese in biological Samples of Steel mill workers by electrothermal atomic absorption Spectrometry.

    Science.gov (United States)

    Afridi, H I; Kazi, T G; Kazi, N G; Jamali, M K; Arain, M B; Sirajuddin; Kandhro, G A; Shah, A Q; Baig, J A

    2009-02-01

    The determination of trace and toxic elements in biological samples (blood, urine and scalp hair samples) of human beings is an important clinical test. The aim of our present study was to determine the concentration of arsenic (As), copper (Cu), cobalt (Co) and manganese (Mn), in biological samples of male production workers (PW) and quality control workers (QW) of steel mill, with aged 25-55 years, to assess the possible influence of environmental exposure. For comparison purpose, the same biological samples of unexposed healthy males of same age group were collected as control subjects. The determination of all elements in biological samples was carried out by electrothermal atomic absorption spectrometry, prior to microwave assisted acid digestion. The accuracy of the As, Cu, Co and Mn measurements was tested by simultaneously analyzing certified reference materials (CRMs) and for comparative purposes conventional wet acid digestion method was used on the same CRMs. No significant differences were observed between the analytical results and the certified values, using both methods (paired t-test at P > 0.05). The results indicate that concentrations of As, Cu, Co and Mn in all three biological samples of the exposed workers (QW and PW) were significantly higher than those of the controls. The possible correlation of these elements with the etiology of different physiological disorders is discussed. The results were also demonstrated the need of attention for improvements in workplace, ventilation and industrial hygiene practices.

  4. Supercritical fluid carbon dioxide extraction and liquid chromatographic separation with electrochemical detection of methylmercury from biological samples

    Science.gov (United States)

    Simon, N.S.

    1997-01-01

    Using the coupled methods presented in this paper, methylmercury can be accurately and rapidly extracted from biological samples by modified supercritical fluid carbon dioxide and quantitated using liquid chromatography with reductive electrochemical detection. Supercritical fluid carbon dioxide modified with methanol effectively extracts underivatized methylmercury from certified reference materials Dorm-1 (dogfish muscle) and Dolt-2 (dogfish liver). Calcium chloride and water, with a ratio of 5:2 (by weight), provide the acid environment required for extracting methylmercury from sample matrices. Methylmercury chloride is separated from other organomercury chloride compounds using HPLC. The acidic eluent, containing 0.06 mol L-1 NaCl, insures the presence of methylmercury chloride and facilitates the reduction of mercury on a glassy carbon electrode. If dual glassy carbon electrodes are used, a positive peak is observed at -0.65 to -0.70 V and a negative peak is observed at -0.90V with the organomercury compounds that were tested. The practical detection limit for methylmercury is 5 X 10-8 mol L-1 (1 X 10-12 tool injected) when a 20 ??L injection loop is used.

  5. Analysis of inorganic elements in biological samples of C57BL/6J mouse strain using INAA

    Energy Technology Data Exchange (ETDEWEB)

    Metairon, Sabrina; Zamboni, Cibele B.; Suzuki, Miriam F.; Kovacs, Luciana, E-mail: metairon@usp.br, E-mail: czamboni@ipen.br, E-mail: mfsuzuki@ipen.br, E-mail: lukovacs@gmail.com [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil); Bueno Junior, Carlos R., E-mail: carmao11@yahoo.com.br [Universidade de Sao Paulo (IB/USP), Sao Paulo, SP (Brazil). Instituto de Biociencias. Centro de Estudos do Genoma Humano

    2013-07-01

    The research for new medicine, vaccines and other products of interest in health area, for any disease, requires several in vivo tests using animal models on experiments for clinical analysis of actions in organism, focusing on the relation between these and the responses or reactions to their use, allowing or not their use in human being. The present investigation deals with the determination of elements concentration (Ca, Cl, K, Mg and Na) of clinical relevance in kidney and liver of C57BL/6J mice strain using the Instrumental Neutron Activation Analysis technique. Particularly, the C57BL/6J strain is one of the most widely used mice genetically modified for human disease studies. The biological samples were collected from 2 month old adult mice bred in the Biotherium (animal breeding) of UNIFESP (Federal University of Sao Paulo, Brasil) and at Human Genome Research Center (University of Sao Paulo, Brasil) and Biotechnology Center (IPEN, Sao Paulo, Brasil). The measurements were performed in the nuclear reactor IEA-R1 (3.5-4.5MW, pool type) at IPEN. These data will allow researchers to optimize their studies, both in terms of cost and time, by knowing the basal reference values in blood and organs of this strain. Additionally, this analytical procedure meets the needs of the world tendency that emphasizes the requirements to propose alternative methods for clinical research that contribute to animal welfare. (author)

  6. A Feedfordward Adaptive Controller to Reduce the Imaging Time of Large-Sized Biological Samples with a SPM-Based Multiprobe Station

    Directory of Open Access Journals (Sweden)

    Manel Puig-Vidal

    2012-01-01

    Full Text Available The time required to image large samples is an important limiting factor in SPM-based systems. In multiprobe setups, especially when working with biological samples, this drawback can make impossible to conduct certain experiments. In this work, we present a feedfordward controller based on bang-bang and adaptive controls. The controls are based in the difference between the maximum speeds that can be used for imaging depending on the flatness of the sample zone. Topographic images of Escherichia coli bacteria samples were acquired using the implemented controllers. Results show that to go faster in the flat zones, rather than using a constant scanning speed for the whole image, speeds up the imaging process of large samples by up to a 4x factor.

  7. Data Quality Objectives for Regulatory Requirements for Hazardous and Radioactive Air Emissions Sampling and Analysis

    Energy Technology Data Exchange (ETDEWEB)

    MULKEY, C.H.

    1999-07-06

    This document describes the results of the data quality objective (DQO) process undertaken to define data needs for state and federal requirements associated with toxic, hazardous, and/or radiological air emissions under the jurisdiction of the River Protection Project (RPP). Hereafter, this document is referred to as the Air DQO. The primary drivers for characterization under this DQO are the regulatory requirements pursuant to Washington State regulations, that may require sampling and analysis. The federal regulations concerning air emissions are incorporated into the Washington State regulations. Data needs exist for nonradioactive and radioactive waste constituents and characteristics as identified through the DQO process described in this document. The purpose is to identify current data needs for complying with regulatory drivers for the measurement of air emissions from RPP facilities in support of air permitting. These drivers include best management practices; similar analyses may have more than one regulatory driver. This document should not be used for determining overall compliance with regulations because the regulations are in constant change, and this document may not reflect the latest regulatory requirements. Regulatory requirements are also expected to change as various permits are issued. Data needs require samples for both radionuclides and nonradionuclide analytes of air emissions from tanks and stored waste containers. The collection of data is to support environmental permitting and compliance, not for health and safety issues. This document does not address health or safety regulations or requirements (those of the Occupational Safety and Health Administration or the National Institute of Occupational Safety and Health) or continuous emission monitoring systems. This DQO is applicable to all equipment, facilities, and operations under the jurisdiction of RPP that emit or have the potential to emit regulated air pollutants.

  8. Earth Entry Requirements for Mars, Europa and Enceladus Sample Return Missions: A Thermal Protection System Perspective

    Science.gov (United States)

    Venkatapathy, Ethiraj; Gage, Peter; Ellerby, Don; Mahzari, Milad; Peterson, Keith; Stackpoole, Mairead; Young, Zion

    2016-01-01

    This oral presentation will be given at the 13th International Planetary Probe Workshop on June 14th, 2016 and will cover the drivers for reliability and the challenges faced in selecting and designing the thermal protection system (TPS). In addition, an assessment is made on new emerging TPS related technologies that could help with designs to meet the planetary protection requirements to prevent backward (Earth) contamination by biohazardous samples.

  9. Rapid Preparation Methods of Biological Samples for Ionic Compounds Using Ion Exchange Type Monolithic Silica Spin Column

    OpenAIRE

    宮崎, 将太; 山田, 智子; 太田, 茂徳; 斉藤, 剛; 奈女良, 昭; 大平, 真義

    2010-01-01

    We developed a device comprising a spin column packed with ion exchange type (SCX and SAX) monolithic silica for extracting ionic compounds from biological samples. The methods involving the use of these spin column are not useful for the extraction of ionic analytes, but are highly reproducible for the analysis in serum and urine. This spin column enabled sample preparation in less than 10 min. Handling such as sample loading, washing, and elution of analytes, was exhibited by the centrifuga...

  10. Fast screening of ketamine in biological samples based on molecularly imprinted photonic hydrogels

    Energy Technology Data Exchange (ETDEWEB)

    Meng, Liang [Department of Forensic Science, People' s Public Security University of China, Beijing (China); Meng, Pinjia, E-mail: mengpinjia@163.com [Department of Forensic Science, People' s Public Security University of China, Beijing (China); Zhang, Qingqing; Wang, Yanji [Department of Forensic Science, People' s Public Security University of China, Beijing (China)

    2013-04-10

    Graphical abstract: A novel label-free colorimetric chemosensor: with the increase in the concentration of ketamine, the Bragg diffraction peak of MIPHs gradually shifted to the longer wavelength region. Accompanying the peak shift, the color change of MIPHs was also observed obviously: from green to red. Highlights: ► We developed the label-free colorimetric MIPHs for handy and fast screening of ketamine. ► The obvious color change of MIPHs was observed upon ketamine. ► The MIPHs exhibited good sensing abilities in an aqueous environment. ► The sensing mechanisms of the water-compatible MIPHs were investigated. ► The MIPHs were employed to screening ketamine in real biological samples. -- Abstract: A novel label-free colorimetric chemosensor was developed for handy and fast screening of ketamine with high sensitivity and specificity based on molecularly imprinted photonic hydrogels (MIPHs) that combined the colloidal-crystal with molecular imprinting technique. The unique inverse opal arrays with a thin polymer wall in which the imprinted nanocavities of ketamine moleculars distributed allowed high sensitive, quick responsive, specific detection of the target analyte, and good regenerating ability in an aqueous environment. Due to the hierarchical inverse opal structural characteristics, the specific ketamine molecular recognition process can induce obvious swelling of the MIPHs to be directly transferred into visually perceptible optical signal (change in color) which can be detected by the naked eye through Bragg diffractive shifts of ordered macroporous arrays. In order to enhance the recognition ability in aqueous environments, the MIPHs were designed as water-compatible and synthesized in a water–methanol system. The molecular recognition mechanisms were investigated. The proposed MIPHs were successfully employed to screen trace level ketamine in human urine and saliva samples, exhibiting high sensitivity, rapid response, and specificity in the

  11. Nanoparticle sensor for label free detection of swine DNA in mixed biological samples

    Science.gov (United States)

    Ali, M. E.; Hashim, U.; Mustafa, S.; Che Man, Y. B.; Yusop, M. H. M.; Bari, M. F.; Islam, Kh N.; Hasan, M. F.

    2011-05-01

    We used 40 ± 5 nm gold nanoparticles (GNPs) as colorimetric sensor to visually detect swine-specific conserved sequence and nucleotide mismatch in PCR-amplified and non-amplified mitochondrial DNA mixtures to authenticate species. Colloidal GNPs changed color from pinkish-red to gray-purple in 2 mM PBS. Visually observed results were clearly reflected by the dramatic reduction of surface plasmon resonance peak at 530 nm and the appearance of new features in the 620-800 nm regions in their absorption spectra. The particles were stabilized against salt-induced aggregation upon the adsorption of single-stranded DNA. The PCR products, without any additional processing, were hybridized with a 17-base probe prior to exposure to GNPs. At a critical annealing temperature (55 °C) that differentiated matched and mismatched base pairing, the probe was hybridized to pig PCR product and dehybridized from the deer product. The dehybridized probe stuck to GNPs to prevent them from salt-induced aggregation and retained their characteristic red color. Hybridization of a 27-nucleotide probe to swine mitochondrial DNA identified them in pork-venison, pork-shad and venison-shad binary admixtures, eliminating the need of PCR amplification. Thus the assay was applied to authenticate species both in PCR-amplified and non-amplified heterogeneous biological samples. The results were determined visually and validated by absorption spectroscopy. The entire assay (hybridization plus visual detection) was performed in less than 10 min. The LOD (for genomic DNA) of the assay was 6 µg ml - 1 swine DNA in mixed meat samples. We believe the assay can be applied for species assignment in food analysis, mismatch detection in genetic screening and homology studies between closely related species.

  12. Nanoparticle sensor for label free detection of swine DNA in mixed biological samples.

    Science.gov (United States)

    Ali, M E; Hashim, U; Mustafa, S; Man, Y B Che; Yusop, M H M; Bari, M F; Islam, Kh N; Hasan, M F

    2011-05-13

    We used 40 ± 5 nm gold nanoparticles (GNPs) as colorimetric sensor to visually detect swine-specific conserved sequence and nucleotide mismatch in PCR-amplified and non-amplified mitochondrial DNA mixtures to authenticate species. Colloidal GNPs changed color from pinkish-red to gray-purple in 2 mM PBS. Visually observed results were clearly reflected by the dramatic reduction of surface plasmon resonance peak at 530 nm and the appearance of new features in the 620-800 nm regions in their absorption spectra. The particles were stabilized against salt-induced aggregation upon the adsorption of single-stranded DNA. The PCR products, without any additional processing, were hybridized with a 17-base probe prior to exposure to GNPs. At a critical annealing temperature (55 °C) that differentiated matched and mismatched base pairing, the probe was hybridized to pig PCR product and dehybridized from the deer product. The dehybridized probe stuck to GNPs to prevent them from salt-induced aggregation and retained their characteristic red color. Hybridization of a 27-nucleotide probe to swine mitochondrial DNA identified them in pork-venison, pork-shad and venison-shad binary admixtures, eliminating the need of PCR amplification. Thus the assay was applied to authenticate species both in PCR-amplified and non-amplified heterogeneous biological samples. The results were determined visually and validated by absorption spectroscopy. The entire assay (hybridization plus visual detection) was performed in less than 10 min. The LOD (for genomic DNA) of the assay was 6 µg ml(-1) swine DNA in mixed meat samples. We believe the assay can be applied for species assignment in food analysis, mismatch detection in genetic screening and homology studies between closely related species.

  13. Nanoparticle sensor for label free detection of swine DNA in mixed biological samples

    Energy Technology Data Exchange (ETDEWEB)

    Ali, M E; Hashim, U [Institute of Nano Electronic Engineering (INNE), Universiti Malaysia Perlis, Lot 104-108, Tingkat 1, Block A, Taman Pertiwi Indah, Jalan Kangar-Alor Star, Seriab, 01000 Kangar, Perlis (Malaysia); Mustafa, S; Che Man, Y B; Yusop, M H M [Halal Products Research Institute, Universiti Putra Malaysia, 43400 UPM Serdang, Selangor (Malaysia); Bari, M F [School of Materials Engineering, University Malaysia Perlis, Seriab 01000, Kangar, Perlis (Malaysia); Islam, Kh N [Department of Preclinical Sciences, Faculty of Veterinary Medicine, Universiti Putra Malaysia, 43400 UPM Serdang, Selangor (Malaysia); Hasan, M F, E-mail: uda@unimap.edu.my [Department of Crop Science, Faculty of Agriculture, Universiti Putra Malaysia, 43400 UPM Serdang, Selangor (Malaysia)

    2011-05-13

    We used 40 {+-} 5 nm gold nanoparticles (GNPs) as colorimetric sensor to visually detect swine-specific conserved sequence and nucleotide mismatch in PCR-amplified and non-amplified mitochondrial DNA mixtures to authenticate species. Colloidal GNPs changed color from pinkish-red to gray-purple in 2 mM PBS. Visually observed results were clearly reflected by the dramatic reduction of surface plasmon resonance peak at 530 nm and the appearance of new features in the 620-800 nm regions in their absorption spectra. The particles were stabilized against salt-induced aggregation upon the adsorption of single-stranded DNA. The PCR products, without any additional processing, were hybridized with a 17-base probe prior to exposure to GNPs. At a critical annealing temperature (55 {sup 0}C) that differentiated matched and mismatched base pairing, the probe was hybridized to pig PCR product and dehybridized from the deer product. The dehybridized probe stuck to GNPs to prevent them from salt-induced aggregation and retained their characteristic red color. Hybridization of a 27-nucleotide probe to swine mitochondrial DNA identified them in pork-venison, pork-shad and venison-shad binary admixtures, eliminating the need of PCR amplification. Thus the assay was applied to authenticate species both in PCR-amplified and non-amplified heterogeneous biological samples. The results were determined visually and validated by absorption spectroscopy. The entire assay (hybridization plus visual detection) was performed in less than 10 min. The LOD (for genomic DNA) of the assay was 6 {mu}g ml{sup -1} swine DNA in mixed meat samples. We believe the assay can be applied for species assignment in food analysis, mismatch detection in genetic screening and homology studies between closely related species.

  14. Electronic noses for monitoring benzene occupational exposure in biological samples of Egyptian workers

    Directory of Open Access Journals (Sweden)

    Ehab I. Mohamed

    2013-02-01

    Full Text Available Objectives: Benzene is commonly emitted in several industries, leading to widespread environmental and occupational exposure hazards. While less toxic solvents have been substituted for benzene, it is still a component of petroleum products and is a trace impurity in industrial products resulting in continued higher occupational exposures in industrial settings in developing countries. Materials and Methods: We investigated the potential use of an electronic nose (e-nose to monitor the headspace volatiles in biological samples from benzene-exposed Egyptian workers and non-exposed controls. The study population comprised 150 non-smoking male workers exposed to benzene and an equal number of matching non-exposed controls. We determined biomarkers of benzene used to estimate exposure and risk including: benzene in exhaled air and blood; and its urinary metabolites such as phenol and muconic acid using gas chromatography technique and a portable e-nose. Results: The average benzene concentration measured in the ambient air of the workplace of all studied industrial settings in Alexandria, Egypt; was 97.56±88.12 μg/m3 (range: 4.69–260.86 μg/m3. Levels of phenol and muconic acid were signifi cantly (p < 0.001 higher in both blood and urine of benzene-exposed workers as compared to non-exposed controls. Conclusions: The e-nose technology has successfully classifi ed and distinguished benzene-exposed workers from non-exposed controls for all measured samples of blood, urine and the exhaled air with a very high degree of precision. Thus, it will be a very useful tool for the low-cost mass screening and early detection of health hazards associated with the exposure to benzene in the industry.

  15. State of the art of environmentally friendly sample preparation approaches for determination of PBDEs and metabolites in environmental and biological samples: A critical review.

    Science.gov (United States)

    Berton, Paula; Lana, Nerina B; Ríos, Juan M; García-Reyes, Juan F; Altamirano, Jorgelina C

    2016-01-28

    Green chemistry principles for developing methodologies have gained attention in analytical chemistry in recent decades. A growing number of analytical techniques have been proposed for determination of organic persistent pollutants in environmental and biological samples. In this light, the current review aims to present state-of-the-art sample preparation approaches based on green analytical principles proposed for the determination of polybrominated diphenyl ethers (PBDEs) and metabolites (OH-PBDEs and MeO-PBDEs) in environmental and biological samples. Approaches to lower the solvent consumption and accelerate the extraction, such as pressurized liquid extraction, microwave-assisted extraction, and ultrasound-assisted extraction, are discussed in this review. Special attention is paid to miniaturized sample preparation methodologies and strategies proposed to reduce organic solvent consumption. Additionally, extraction techniques based on alternative solvents (surfactants, supercritical fluids, or ionic liquids) are also commented in this work, even though these are scarcely used for determination of PBDEs. In addition to liquid-based extraction techniques, solid-based analytical techniques are also addressed. The development of greener, faster and simpler sample preparation approaches has increased in recent years (2003-2013). Among green extraction techniques, those based on the liquid phase predominate over those based on the solid phase (71% vs. 29%, respectively). For solid samples, solvent assisted extraction techniques are preferred for leaching of PBDEs, and liquid phase microextraction techniques are mostly used for liquid samples. Likewise, green characteristics of the instrumental analysis used after the extraction and clean-up steps are briefly discussed.

  16. Postmarketing safety reports for human drug and biological products; electronic submission requirements. Final rule.

    Science.gov (United States)

    2014-06-10

    The Food and Drug Administration (FDA or we) is amending its postmarketing safety reporting regulations for human drug and biological products to require that persons subject to mandatory reporting requirements submit safety reports in an electronic format that FDA can process, review, and archive. FDA is taking this action to improve the Agency's systems for collecting and analyzing postmarketing safety reports. The change will help the Agency to more rapidly review postmarketing safety reports, identify emerging safety problems, and disseminate safety information in support of FDA's public health mission. In addition, the amendments will be a key element in harmonizing FDA's postmarketing safety reporting regulations with international standards for the electronic submission of safety information.

  17. Analysis of six relevant toxaphene congeners in biological samples using ion trap MS/MS.

    Science.gov (United States)

    Gouteux, Bruno; Lebeuf, Michel; Trottier, Steve; Gagné, Jean-Pierre

    2002-10-01

    The quantification of six polychlorinated bornanes (CHBs) was studied using ion trap MS/MS. The significance of the selection of parent ions (Ip) and daughter ions (Id) on the detection of these toxaphene congeners was assessed in standard solution and biological samples. Our results indicate that different Ip and Id, selected at either low or high mass-to-charge (m/z) ratios, influence drastically the response factor of the CHBs and the chemical noise observed. For the octachlorinated toxaphene congeners (Parlar-26 (P-26), Parlar-40/41 (P-40/41), Parlar-44 (P-44)), the detection performance of the ion trap MS/MS is similar whether Ip and Id were chosen at low or high m/z ratios. However, the selection of Ip and Id at high m/z ratios clearly enhances the detection of the nonachlorinated toxaphene congeners (Parlar-50 (P-50), Parlar-62 (P-62)). The improved method, which selects Ip and Id at low m/z ratios for P-26, P-40/41 and P-44 and at high m/z ratios for P-50 and P-62, permitted to obtain low detection limits as well as repeatable and accurate results.

  18. Microwave-accelerated bioassay technique for rapid and quantitative detection of biological and environmental samples.

    Science.gov (United States)

    Mohammed, Muzaffer; Syed, Maleeha F; Aslan, Kadir

    2016-01-15

    Quantitative detection of molecules of interest from biological and environmental samples in a rapid manner, particularly with a relevant concentration range, is imperative to the timely assessment of human diseases and environmental issues. In this work, we employed the microwave-accelerated bioassay (MAB) technique, which is based on the combined use of circular bioassay platforms and microwave heating, for rapid and quantitative detection of Glial Fibrillary Acidic Protein (GFAP) and Shiga like toxin (STX 1). The proof-of-principle use of the MAB technique with the circular bioassay platforms for the rapid detection of GFAP in buffer based on colorimetric and fluorescence readouts was demonstrated with a 900W kitchen microwave. We also employed the MAB technique with a new microwave system (called the iCrystal system) for the detection of GFAP from mice with brain injuries and STX 1 from a city water stream. Control bioassays included the commercially available gold standard bioassay kits run at room temperature. Our results show that the lower limit of detection (LLOD) of the colorimetric and fluorescence based bioassays for GFAP was decreased by ~1000 times using the MAB technique and our circular bioassay platforms as compared to the commercially available bioassay kits. The overall bioassay time for GFAP and STX 1 was reduced from 4h using commercially available bioassay kits to 10min using the MAB technique.

  19. Substrate-zymography: a still worthwhile method for gelatinases analysis in biological samples.

    Science.gov (United States)

    Ricci, Serena; D'Esposito, Vittoria; Oriente, Francesco; Formisano, Pietro; Di Carlo, Angelina

    2016-08-01

    Matrix metallo-proteinases (MMPs) are a family of zinc-dependent endopeptidases, capable of degrading all the molecular components of extracellular matrix. A class of MMPs is gelatinases which includes gelatinase A or MMP-2 (72 kDa) and gelatinase B or MMP-9 (92 kDa), which have been shown to play critical roles in pathophysiology of many human disease and, in particular, cancer progression. For these reasons they obtained a great interest as potential non-invasive biomarker in providing useful clinical information in cancer diagnosis and therapy. A sensitive and unexpensive method for analysis of gelatinases is the gelatine zymography, which allows to measure the relative amounts of active and inactive enzymes in body fluids and tissue extracts. The procedure involves the electrophoretic separation of proteins under denaturing but non reducing conditions through a polyacrylamide gel containing a synthetic substrate (gelatin). The aim of this mini-review has been to describe the general principles of gelatine zymography technique, underling the main advantages and disadvantages. Even though an improvement of this method is necessary for a better applicability in laboratory medicine, gelatine zymography represents the most convenient method to detect the activity of the different gelatinases from a wide range of biological samples.

  20. Cyclopentanone thiosemicarbazone, a new complexing agent for copper determination in biological samples by adsorptive stripping voltammetry.

    Science.gov (United States)

    Mahajan, Rakesh Kumar; Walia, T P S; Sumanjit; Lobana, T S

    2006-03-01

    A selective and sensitive stripping voltammetric method for the determination of trace amounts of copper(II) with cyclopentanone thiosemicarbazone (CPTSC) is presented. The method is based on the adsorptive accumulation of the resulting copper-CPTSC complex on a hanging mercury drop electrode, followed by the stripping voltammetric measurements at the reduction current of the adsorbed complex at -0.37 V vs. Ag/AgCl. The optimal conditions for the stripping analysis of copper include pH 9.3, deposition time of 120 s, and a deposition potential of -0.1 V (vs. Ag/AgCl). The peak current is linearly proportional to the copper concentration over a range 3.14 x 10(-9) M to 1.57 x 10(-6) M with a limit of detection of 1.57 x 10(-9) M. The technique has been applied to the determination of copper in biological samples, like urine and whole blood.

  1. BORRELIA BURGDORFERI DNA IN BIOLOGICAL SAMPLES FROM PATIENTS WITH SARCOIDOSIS USING THE POLYMERASE CHAIN REACTION TECHNIQUE

    Institute of Scientific and Technical Information of China (English)

    连伟; 罗慰慈

    1995-01-01

    Polymerase chain reaction (PCR) was used to detect the presence of Borretia burgdoferi DNA in biological samples from patients with sarcoidcsis. The target DNA sequence was of chromosomal origin. The amplified DNA sequence was analyzed by agarose gel electrophoresis, PAGE with silver staining, and the identity of amplified DNA was confirmed by restriction enzyme cleavage and DNA-DNA hybridlzation with a 32P-labelled probe. The assay was sensitive to fewer than two copies of B. burgdor feri genome, even in the presence of a 104-fold excess of human eukaryotic DNA, and was also specific to different B. burgdorferl strains tested. Sera seroiogieally positive to B. burgdorferi (n=26), broncbemlveolar lavage fluid and supematant of BALF (n=26) and peripheral blood (n=9) from sarcoidosis patients were tested. The positive rate was low (4/26, 2/26, and 0/9, respectively). It was considered that DNA from B. bur gdor feri may be identified in a minority of patients with s,arcoidosis, and it may play a pathogenetic rote in such cases. More studies need to be done before advancing the hypothesis of an etiologic role of B. burgdorferi in sarcoidosis.

  2. Development of novel separation techniques for biological samples in capillary electrophoresis

    Energy Technology Data Exchange (ETDEWEB)

    Chang, Huan -Tsung [Iowa State Univ., Ames, IA (United States)

    1994-07-27

    This dissertation includes three different topics: general introduction of capillary electrophoresis (CE); gradient in CE and CE in biological separations; and capillary gel electrophoresis (CGE) for DNA separation. Factors such as temperature, viscosity, pH, and the surface of capillary walls affecting the separation performance are demonstrated. A pH gradient between 3.0 and 5.2 is useful to improve the resolution among eight different organic acids. A flow gradient due to the change in the concentration of surfactant, which is able to coat to the capillary wall to change the flow rate and its direction, is also shown as a good way to improve the resolution for organic compounds. A temperature gradient caused by joule heat is shown by voltage programming to enhance the resolution and shorten the separation time for several phenolic compounds. The author also shows that self-regulating dynamic control of electroosmotic flow in CE by simply running separation in different concentrations of surfactant has less matrix effect on the separation performance. One of the most important demonstrations in this dissertation is that the author proposes on-column reaction which gives several advantages including the use of a small amount of sample, low risk of contamination, and time saving and kinetic features. The author uses this idea with laser induced fluorescence (LIF) as a detection mode to detect an on-column digestion of sub-ng of protein. This technique also is applied to single cell analysis in the group.

  3. Development of a new catalase activity assay for biological samples using optical CUPRAC sensor

    Science.gov (United States)

    Bekdeşer, Burcu; Özyürek, Mustafa; Güçlü, Kubilay; Alkan, Fulya Üstün; Apak, Reşat

    2014-11-01

    A novel catalase activity assay was developed for biological samples (liver and kidney tissue homogenates) using a rapid and low-cost optical sensor-based ‘cupric reducing antioxidant capacity' (CUPRAC) method. The reagent, copper(II)-neocuproine (Cu(II)-Nc) complex, was immobilized onto a cation-exchanger film of Nafion, and the absorbance changes associated with the formation of the highly-colored Cu(I)-Nc chelate as a result of reaction with hydrogen peroxide (H2O2) was measured at 450 nm. When catalase was absent, H2O2 produced the CUPRAC chromophore, whereas catalase, being an effective H2O2 scavenger, completely annihilated the CUPRAC signal due to H2O2. Thus, the CUPRAC absorbance due to H2O2 oxidation concomitant with Cu(I)-Nc formation decreased proportionally with catalase. The developed sensor gave a linear response over a wide concentration range of H2O2 (0.68-78.6 μM). This optical sensor-based method applicable to tissue homogenates proved to be efficient for low hydrogen peroxide concentrations (physiological and nontoxic levels) to which the widely used UV method is not accurately responsive. Thus, conventional problems of the UV method arising from relatively low sensitivity and selectivity, and absorbance disturbance due to gaseous oxygen evolution were overcome. The catalase findings of the proposed method for tissue homogenates were statistically alike with those of HPLC.

  4. SLEPR: a sample-level enrichment-based pathway ranking method -- seeking biological themes through pathway-level consistency.

    Science.gov (United States)

    Yi, Ming; Stephens, Robert M

    2008-09-26

    Analysis of microarray and other high throughput data often involves identification of genes consistently up or down-regulated across samples as the first step in extraction of biological meaning. This gene-level paradigm can be limited as a result of valid sample fluctuations and biological complexities. In this report, we describe a novel method, SLEPR, which eliminates this limitation by relying on pathway-level consistencies. Our method first selects the sample-level differentiated genes from each individual sample, capturing genes missed by other analysis methods, ascertains the enrichment levels of associated pathways from each of those lists, and then ranks annotated pathways based on the consistency of enrichment levels of individual samples from both sample classes. As a proof of concept, we have used this method to analyze three public microarray datasets with a direct comparison with the GSEA method, one of the most popular pathway-level analysis methods in the field. We found that our method was able to reproduce the earlier observations with significant improvements in depth of coverage for validated or expected biological themes, but also produced additional insights that make biological sense. This new method extends existing analyses approaches and facilitates integration of different types of HTP data.

  5. Dimensional comparison between amplitude-modulation atomic force microscopy and scanning ion conductance microscopy of biological samples

    Science.gov (United States)

    Kim, Joonhui; Choi, MyungHoon; Jung, Goo-Eun; Rahim Ferhan, Abdul; Cho, Nam-Joon; Cho, Sang-Joon

    2016-08-01

    The range of scanning probe microscopy (SPM) applications for atomic force microscopy (AFM) is expanding in the biological sciences field, reflecting an increasing demand for tools that can improve our fundamental understanding of the physics behind biological systems. However, the complexity associated with applying SPM techniques in biomedical research hampers the full exploitation of its capabilities. Recently, the development of scanning ion conductance microscopy (SICM) has overcome these limitations and enabled contact-free, high resolution imaging of live biological specimens. In this work, we demonstrate the limitation of AFM for imaging biological samples in liquid due to artifacts arising from AFM tip-sample interaction, and how SICM imaging is able to overcome those limitations with contact-free scanning. We also demonstrate that SICM measurements, when compared to AFM, show better fit to the actual dimensions of the biological samples. Our results highlight the superiority of SICM imaging, enabling it to be widely adopted as a general and versatile research tool for biological studies in the nanoscale.

  6. Insights on antioxidant assays for biological samples based on the reduction of copper complexes-the importance of analytical conditions.

    Science.gov (United States)

    Marques, Sara S; Magalhães, Luís M; Tóth, Ildikó V; Segundo, Marcela A

    2014-06-25

    Total antioxidant capacity assays are recognized as instrumental to establish antioxidant status of biological samples, however the varying experimental conditions result in conclusions that may not be transposable to other settings. After selection of the complexing agent, reagent addition order, buffer type and concentration, copper reducing assays were adapted to a high-throughput scheme and validated using model biological antioxidant compounds of ascorbic acid, Trolox (a soluble analogue of vitamin E), uric acid and glutathione. A critical comparison was made based on real samples including NIST-909c human serum certified sample, and five study samples. The validated method provided linear range up to 100 µM Trolox, (limit of detection 2.3 µM; limit of quantification 7.7 µM) with recovery results above 85% and precision <5%. The validated developed method with an increased sensitivity is a sound choice for assessment of TAC in serum samples.

  7. Insights on Antioxidant Assays for Biological Samples Based on the Reduction of Copper Complexes—The Importance of Analytical Conditions

    Directory of Open Access Journals (Sweden)

    Sara S. Marques

    2014-06-01

    Full Text Available Total antioxidant capacity assays are recognized as instrumental to establish antioxidant status of biological samples, however the varying experimental conditions result in conclusions that may not be transposable to other settings. After selection of the complexing agent, reagent addition order, buffer type and concentration, copper reducing assays were adapted to a high-throughput scheme and validated using model biological antioxidant compounds of ascorbic acid, Trolox (a soluble analogue of vitamin E, uric acid and glutathione. A critical comparison was made based on real samples including NIST-909c human serum certified sample, and five study samples. The validated method provided linear range up to 100 µM Trolox, (limit of detection 2.3 µM; limit of quantification 7.7 µM with recovery results above 85% and precision <5%. The validated developed method with an increased sensitivity is a sound choice for assessment of TAC in serum samples.

  8. Sample size requirements and analysis of tag recoveries for paired releases of lake trout

    Science.gov (United States)

    Elrod, Joseph H.; Frank, Anthony

    1990-01-01

    A simple chi-square test can be used to analyze recoveries from a paired-release experiment to determine whether differential survival occurs between two groups of fish. The sample size required for analysis is a function of (1) the proportion of fish stocked, (2) the expected proportion at recovery, (3) the level of significance (a) at which the null hypothesis is tested, and (4) the power (1-I?) of the statistical test. Detection of a 20% change from a stocking ratio of 50:50 requires a sample of 172 (I?=0.10; 1-I?=0.80) to 459 (I?=0.01; 1-I?=0.95) fish. Pooling samples from replicate pairs is sometimes an appropriate way to increase statistical precision without increasing numbers stocked or sampling intensity. Summing over time is appropriate if catchability or survival of the two groups of fish does not change relative to each other through time. Twelve pairs of identical groups of yearling lake trout Salvelinus namaycush were marked with coded wire tags and stocked into Lake Ontario. Recoveries of fish at ages 2-8 showed differences of 1-14% from the initial stocking ratios. Mean tag recovery rates were 0.217%, 0.156%, 0.128%, 0.121%, 0.093%, 0.042%, and 0.016% for ages 2-8, respectively. At these rates, stocking 12,100-29,700 fish per group would yield samples of 172-459 fish at ages 2-8 combined.

  9. Automated extraction of DNA from reference samples from various types of biological materials on the Qiagen BioRobot EZ1 Workstation

    DEFF Research Database (Denmark)

    Stangegaard, Michael; Jørgensen, Mads; Hansen, Anders Johannes

    2009-01-01

    We have validated and implemented a protocol for DNA extraction from various types of biological materials using a Qiagen BioRobot EZ1 Workstation. The sample materials included whole blood, blood from deceased, buccal cells on Omni swabs and FTA Cards, blood on FTA Cards and cotton swabs......, and muscle biopsies. The DNA extraction was validated according to EN/ISO 17025 for the STR kits AmpFlSTR« Identifiler« and AmpFlSTR« Yfiler« (Applied Biosystems). Of 298 samples extracted, 11 (4%) did not yield acceptable results. In conclusion, we have demonstrated that extraction of DNA from various types...... of biological material can be performed quickly and without the use of hazardous chemicals, and that the DNA may be successfully STR typed according to the requirements of forensic genetic investigations accredited according to EN/ISO 17025...

  10. Production and use of mycotoxins uniformly enriched with stable isotopes for their dosage in biological samples: (3) Tools for pharmacokinetics and as internal standards

    Energy Technology Data Exchange (ETDEWEB)

    Bravin, F.; Delaforge, M.; Duca, R.C. [CNRS, URA 2096, F-91191 Gif Sur Yvette (France); Bravin, F.; Delaforge, M.; Duca, R.C. [CEA Saclay, DSV, DBJC, SBFM, F-91191 Gif Sur Yvette (France); Pean, M. [CEA Cadarache, DEVM, GRAP, St Paul Les Durance (France); Puel, O. [INRA, Lab Pharmacol Toxicol, UR 66, Toulouse (France)

    2007-07-01

    Pharmacological studies of exogenous compounds often encounter problems: these compounds are in such infinitesimal amount in their biological matrices, that they require particular detection method. We have implemented an alternative method to the usual radioactivity, based on incorporation of stable isotopes, through the example of biosynthesis of uniformly {sup 13}C enriched mycotoxins. The isotopic cluster obtained from a 10% {sup 13}C enrichment of several mycotoxins (and their metabolites) can be easily recovered from biological tissue samples by mass spectrometry allowing an easy discrimination from natural non-enriched compounds. We illustrate such pharmacological approaches by in vitro zearalenone metabolism. Such enriched compound can also be used as internal standard with high reliability in order to quantify mycotoxins in contaminated food samples. (authors)

  11. An experimental system for controlled exposure of biological samples to electrostatic discharges.

    Science.gov (United States)

    Marjanovič, Igor; Kotnik, Tadej

    2013-12-01

    Electrostatic discharges occur naturally as lightning strokes, and artificially in light sources and in materials processing. When an electrostatic discharge interacts with living matter, the basic physical effects can be accompanied by biophysical and biochemical phenomena, including cell excitation, electroporation, and electrofusion. To study these phenomena, we developed an experimental system that provides easy sample insertion and removal, protection from airborne particles, observability during the experiment, accurate discharge origin positioning, discharge delivery into the sample either through an electric arc with adjustable air gap width or through direct contact, and reliable electrical insulation where required. We tested the system by assessing irreversible electroporation of Escherichia coli bacteria (15 mm discharge arc, 100 A peak current, 0.1 μs zero-to-peak time, 0.2 μs peak-to-halving time), and gene electrotransfer into CHO cells (7 mm discharge arc, 14 A peak current, 0.5 μs zero-to-peak time, 1.0 μs peak-to-halving time). Exposures to natural lightning stroke can also be studied with this system, as due to radial current dissipation, the conditions achieved by a stroke at a particular distance from its entry are also achieved by an artificial discharge with electric current downscaled in magnitude, but similar in time course, correspondingly closer to its entry.

  12. Humidity-controlled preparation of frozen-hydrated biological samples for cryogenic coherent x-ray diffraction microscopy

    Energy Technology Data Exchange (ETDEWEB)

    Takayama, Yuki; Nakasako, Masayoshi [Department of Physics, Faculty of Science and Technology, Keio University, 3-14-1 Hiyoshi, Kohoku-ku, Kanagawa 223-8522 (Japan); RIKEN Harima Institute/SPring-8, 1-1-1 Kouto, Mikaduki, Sayo, Hyogo 679-5148 (Japan)

    2012-05-15

    Coherent x-ray diffraction microscopy (CXDM) has the potential to visualize the structures of micro- to sub-micrometer-sized biological particles, such as cells and organelles, at high resolution. Toward advancing structural studies on the functional states of such particles, here, we developed a system for the preparation of frozen-hydrated biological samples for cryogenic CXDM experiments. The system, which comprised a moist air generator, microscope, micro-injector mounted on a micromanipulator, custom-made sample preparation chamber, and flash-cooling device, allowed for the manipulation of sample particles in the relative humidity range of 20%-94%rh at 293 K to maintain their hydrated and functional states. Here, we report the details of the system and the operation procedure, including its application to the preparation of a frozen-hydrated chloroplast sample. Sample quality was evaluated through a cryogenic CXDM experiment conducted at BL29XUL of SPring-8. Taking the performance of the system and the quality of the sample, the system was suitable to prepare frozen-hydrated biological samples for cryogenic CXDM experiments.

  13. Accelerator mass spectrometry analysis of {sup 14}C-oxaliplatin concentrations in biological samples and {sup 14}C contents in biological samples and antineoplastic agents

    Energy Technology Data Exchange (ETDEWEB)

    Toyoguchi, Teiko, E-mail: tteiko@med.id.yamagata-u.ac.jp [Department of Pharmacy, Yamagata University Hospital, 2-2-2 Iida-Nishi, Yamagata-shi, Yamagata 990-9585 (Japan); Kobayashi, Takeshi; Konno, Noboru; Shiraishi, Tadashi [Department of Pharmacy, Yamagata University Hospital, 2-2-2 Iida-Nishi, Yamagata-shi, Yamagata 990-9585 (Japan); Kato, Kazuhiro; Tokanai, Fuyuki [Department of Physics, Faculty of Science, Yamagata University, 1-4-12 Kojirakawa-machi, Yamagata-shi, Yamagata 990-8560 (Japan)

    2015-10-15

    Accelerator mass spectrometry (AMS) is expected to play an important role in microdose trials. In this study, we measured the {sup 14}C concentration in {sup 14}C-oxaliplatin-spiked serum, urine and supernatant of fecal homogenate samples in our Yamagata University (YU) – AMS system. The calibration curves of {sup 14}C concentration in serum, urine and supernatant of fecal homogenate were linear (the correlation coefficients were ⩾0.9893), and the precision and accuracy was within the acceptance criteria. To examine a {sup 14}C content of water in three vacuum blood collection tubes and a syringe were measured. {sup 14}C was not detected from water in these devices. The mean {sup 14}C content in urine samples of 6 healthy Japanese volunteers was 0.144 dpm/mL, and the intra-day fluctuation of {sup 14}C content in urine from a volunteer was little. The antineoplastic agents are administered to the patients in combination. Then, {sup 14}C contents of the antineoplastic agents were quantitated. {sup 14}C contents were different among 10 antineoplastic agents; {sup 14}C contents of paclitaxel injection and docetaxel hydrate injection were higher than those of the other injections. These results indicate that our quantitation method using YU-AMS system is suited for microdosing studies and that measurement of baseline and co-administered drugs might be necessary for the studies in low concentrations.

  14. Williams Test Required Sample Size For Determining The Minimum Effective Dose

    Directory of Open Access Journals (Sweden)

    Mustafa Agah TEKINDAL

    2016-04-01

    Full Text Available Objective: The biological activity of a substance may be explored through a series of experiments on increased or decreased doses of such substance. One of the purposes in studies of this sort is the determination of minimum effective dose. Use of appropriate sample size has an indisputable effect on the reliability of the decisions made in studies made for this purpose. This study attempts to provide a summary of sample sizes, in different scenarios, needed by researchers during the use of Williams test by taking into consideration the number of groups in dose-response studies as well as minimal clinically significant difference, standard deviation, and the test’s power through asymptotic power analyses. Material and Methods: When Type I error was taken as 0.05, scenarios were determined in different sample sizes for each group (5 to 100 with an increase of 5 at a time and different numbers of groups (from 3 to 10, with an increase of 1 at a time. Minimal clinically significant difference refers to the difference between the control group and the experimental group. In this instance, when the control group is zero and takes a specific average value, it refers to the difference from the experimental group. In the resent study, such differences are defined from 1 to 10 with an increase of 1 at a time. For the test’s power would change when the standard deviation changed, the relevant value was changed in all scenarios from 1 to 10 with an increase of 1 at a time to explore the test’s power. Dose-response distributions are skew. In the present study, data were derived from the Poisson distribution with λ= 1 parameter that was determined in accordance with dose-response curves. Results: When changes occurring in the determined scenarios are considered, it can be said, in general, that the significant difference must be set between 1 and 3; and standard deviation must be set between 1 and 2. Conclusion: It is certain that change in the number

  15. Critical tests for determination of microbiological quality and biological activity in commercial vermicompost samples of different origins.

    Science.gov (United States)

    Grantina-Ievina, Lelde; Andersone, Una; Berkolde-Pīre, Dace; Nikolajeva, Vizma; Ievinsh, Gederts

    2013-12-01

    The aim of the present paper was to show that differences in biological activity among commercially produced vermicompost samples can be found by using a relatively simple test system consisting of microorganism tests on six microbiological media and soilless seedling growth tests with four vegetable crop species. Significant differences in biological properties among analyzed samples were evident both at the level of microbial load as well as plant growth-affecting activity. These differences were mostly manufacturer- and feedstock-associated, but also resulted from storage conditions of vermicompost samples. A mature vermicompost sample that was produced from sewage sludge still contained considerable number of Escherichia coli. Samples from all producers contained several potentially pathogenic fungal species such as Aspergillus fumigatus, Pseudallescheria boidii, Pseudallescheria fimeti, Pseudallescheria minutispora, Scedosporium apiospermum, Scedosporium prolificans, Scopulariopsis brevicaulis, Stachybotrys chartarum, Geotrichum spp., Aphanoascus terreus, and Doratomyces columnaris. In addition, samples from all producers contained plant growth-promoting fungi from the genera Trichoderma and Mortierella. The described system can be useful both for functional studies aiming at understanding of factors affecting quality characteristics of vermicompost preparations and for routine testing of microbiological quality and biological activity of organic waste-derived composts and vermicomposts.

  16. Exploring the cellular and tissue uptake of nanomaterials in a range of biological samples using multimodal nonlinear optical microscopy

    Science.gov (United States)

    Johnston, Helinor J.; Mouras, Rabah; Brown, David M.; Elfick, Alistair; Stone, Vicki

    2015-12-01

    The uptake of nanomaterials (NMs) by cells is critical in determining their potential biological impact, whether beneficial or detrimental. Thus, investigation of NM internalization by cells is a common consideration in hazard and efficacy studies. There are currently a number of approaches that are routinely used to investigate NM-cell interactions, each of which have their own advantages and limitations. Ideally, imaging modalities used to investigate NM uptake by cells should not require the NM to be labelled (e.g. with fluorophores) to facilitate its detection. We present a multimodal imaging approach employing a combination of label-free microscopies that can be used to investigate NM-cell interactions. Coherent anti-Stokes Raman scattering microscopy was used in combination with either two-photon photoluminescence or four-wave mixing (FWM) to visualize the uptake of gold or titanium dioxide NMs respectively. Live and fixed cell imaging revealed that NMs were internalized by J774 macrophage and C3A hepatocyte cell lines (15-31 μg ml-1). Sprague Dawley rats were exposed to NMs (intratracheal instillation, 62 μg) and NMs were detected in blood and lung leucocytes, lung and liver tissue, demonstrating that NMs could translocate from the exposure site. Obtained data illustrate that multimodal nonlinear optical microscopy may help overcome current challenges in the assessment of NM cellular uptake and biodistribution. It is therefore a powerful tool that can be used to investigate unlabelled NM cellular and tissue uptake in three dimensions, requires minimal sample preparation, and is applicable to live and fixed cells.

  17. Pumping time required to obtain tube well water samples with aquifer characteristic radon concentrations

    Energy Technology Data Exchange (ETDEWEB)

    Ricardo, Carla Pereira; Oliveira, Arno Heeren de, E-mail: heeren@nuclear.ufmg.br [Universidade Federal de Minas Gerais (UFMG), Belo Horizonte, MG (Brazil). Escola de Engenharia. Dept. de Engenharia Nuclear; Rocha, Zildete; Palmieri, Helena E.L.; Linhares, Maria G.M.; Menezes, Maria Angela B.C., E-mail: rochaz@cdtn.br, E-mail: help@cdtn.br, E-mail: mgml@cdtn.br, E-mail: menezes@cdtn.br [Centro de Desenvolvimento da Tecnologia Nuclear (CDTN/CNEN-MG), Belo Horizonte, MG (Brazil)

    2011-07-01

    Radon is an inert noble gas, which comes from the natural radioactive decay of uranium and thorium in soil, rock and water. Radon isotopes emanated from radium-bearing grains of a rock or soil are released into the pore space. Radon that reaches the pore space is partitioned between the gaseous and aqueous phases. Thus, the groundwater presents a radon signature from the rock that is characteristic of the aquifer. The characteristic radon concentration of an aquifer, which is mainly related to the emanation, is also influenced by the degree of subsurface degassing, especially in the vicinity of a tube well, where the radon concentration is strongly reduced. Looking for the required pumping time to take a tube well water sample that presents the characteristic radon concentration of the aquifer, an experiment was conducted in an 80 m deep tube well. In this experiment, after twenty-four hours without extraction, water samples were collected periodically, about ten minutes intervals, during two hours of pumping time. The radon concentrations of the samples were determined by using the RAD7 Electronic Radon Detector from Durridge Company, a solid state alpha spectrometric detector. It was realized that the necessary time to reach the maximum radon concentration, that means the characteristic radon concentration of the aquifer, is about sixty minutes. (author)

  18. H2S Analysis in Biological Samples Using Gas Chromatography with Sulfur Chemiluminescence Detection

    OpenAIRE

    Vitvitsky, Victor; Banerjee, Ruma

    2015-01-01

    Hydrogen sulfide (H2S) is a metabolite and signaling molecule in biological tissues that regulates many physiological processes. Reliable and sensitive methods for H2S analysis are necessary for a better understanding of H2S biology and for the pharmacological modulation of H2S levels in vivo. In this chapter, we describe the use of gas chromatography coupled to sulfur chemiluminescence detection to measure the rates of H2S production and degradation by tissue homogenates at physiologically r...

  19. Sampling

    CERN Document Server

    Thompson, Steven K

    2012-01-01

    Praise for the Second Edition "This book has never had a competitor. It is the only book that takes a broad approach to sampling . . . any good personal statistics library should include a copy of this book." —Technometrics "Well-written . . . an excellent book on an important subject. Highly recommended." —Choice "An ideal reference for scientific researchers and other professionals who use sampling." —Zentralblatt Math Features new developments in the field combined with all aspects of obtaining, interpreting, and using sample data Sampling provides an up-to-date treat

  20. Estimation of calcium, magnesium, cadmium, and lead in biological samples from paralyzed quality control and production steel mill workers.

    Science.gov (United States)

    Afridi, Hassan Imran; Talpur, Farah Naz; Kazi, Tasneem Gul; Kazi, Naveed; Arain, Sadaf Sadia; Shah, Faheem

    2015-06-01

    The determination of trace and toxic metals in the biological samples of human beings is an important clinical screening procedure. The aim of the present study was to compare the level of essential trace and toxic elements cadmium (Cd), calcium (Ca), lead (Pb), and magnesium (Mg) in biological samples (whole blood, urine, and scalp hair) of male paralyzed production (PPW) and quality control workers (PQW) of a steel mill, age ranged (35-55 years). For comparison purposes, healthy age-matched exposed referent subjects (EC), working in steel mill and control subjects (NEC), who were not working in industries and lived far away from the industrial areas, were selected as control subjects. The concentrations of electrolytes and toxic elements in biological samples were measured by atomic absorption spectrometry after microwave-assisted acid digestion. The validity and accuracy of the methodology were checked using certified reference materials. The results of this study showed that the mean values of Cd and Pb were significantly higher in scalp hair, blood, and urine samples of PPW and PQW as compared to NEC and EC (p urine samples of PPW and PQW. The results show the need for immediate improvements in workplace, ventilation, and industrial hygiene practices.

  1. Preconcentration and determination of heavy metals in water, sediment and biological samples

    OpenAIRE

    Shirkhanloo Hamid; Mousavi Zavvar Hassan; Rouhollahi Ahmad

    2011-01-01

    In this study, a simple, sensitive and accurate column preconcentration method was developed for the determination of Cd, Cu and Pb ions in river water, urine and sediment samples by flame atomic absorption spectrometry. The procedure is based on the retention of the analytes on a mixed cellulose ester membrane (MCEM) column from buffered sample solutions and then their elution from the column with nitric acid. Several parameters, such as pH of the sample solution, volume of the sample ...

  2. A New Sample Substrate for Imaging and Correlating Organic and Trace Metal Composition in Biological Cells and Tissues

    Energy Technology Data Exchange (ETDEWEB)

    Miller,L.; Wang, Q.; Smith, R.; Zhong, H.; Elliott, D.; Warren, J.

    2007-01-01

    Many disease processes involve alterations in the chemical makeup of tissue. Synchrotron-based infrared (IR) and X-ray fluorescence (XRF) microscopes are becoming increasingly popular tools for imaging the organic and trace metal compositions of biological materials, respectively, without the need for extrinsic labels or stains. Fourier transform infrared microspectroscopy (FTIRM) provides chemical information on the organic components of a material at a diffraction-limited spatial resolution of 2-10 {mu}m in the mid-infrared region. The synchrotron X-ray fluorescence (SXRF) microprobe is a complementary technique used to probe trace element content in the same systems with a similar spatial resolution. However to be most beneficial, it is important to combine the results from both imaging techniques on a single sample, which requires precise overlap of the IR and X-ray images. In this work, we have developed a sample substrate containing a gold grid pattern on its surface, which can be imaged with both the IR and X-ray microscopes. The substrate consists of a low trace element glass slide that has a gold grid patterned on its surface, where the major and minor parts of the grid contain 25 and 12 nm gold, respectively. This grid pattern can be imaged with the IR microscope because the reflectivity of gold differs as a function of thickness. The pattern can also be imaged with the SXRF microprobe because the Au fluorescence intensity changes with gold thickness. The tissue sample is placed on top of the patterned substrate. The grid pattern's IR reflectivity image and the gold SXRF image are used as fiducial markers for spatially overlapping the IR and SXRF images from the tissue. Results show that IR and X-ray images can be correlated precisely, with a spatial resolution of less than one pixel (i.e., 2-3 microns). The development of this new tool will be presented along with applications to paraffin-embedded metalloprotein crystals, Alzheimer's disease

  3. Chiral analysis of amphetamines, methadone and metabolites in biological samples by electrodriven methods.

    Science.gov (United States)

    Mandrioli, Roberto; Mercolini, Laura; Raggi, Maria A

    2011-10-01

    Amphetamines and methadone are synthetic chiral drugs with a high potential for abuse. As such, several analytical methods have been developed for their enantioseparation and analysis in biological tissues, and some of these are based on electrodriven techniques. In this review, the most important and recent of these latter methods are reviewed and their main advantages and disadvantages are discussed. Particular attention is paid to the suitability of each method for the application to the biological matrix of interest: while all methods have been successfully applied for one or more biological tissues, to reach this goal they must overcome the sensitivity problem that is common to almost all capillary electrophoretic techniques. Most methods use one or more cyclodextrin derivatives as the chiral selector, thus the separation mechanism is not particularly complicated or unusual.

  4. Automatic instrument for chemical processing to detect microorganism in biological samples by measuring light reactions

    Science.gov (United States)

    Kelbaugh, B. N.; Picciolo, G. L.; Chappelle, E. W.; Colburn, M. E. (Inventor)

    1973-01-01

    An automated apparatus is reported for sequentially assaying urine samples for the presence of bacterial adenosine triphosphate (ATP) that comprises a rotary table which carries a plurality of sample containing vials and automatically dispenses fluid reagents into the vials preparatory to injecting a light producing luciferase-luciferin mixture into the samples. The device automatically measures the light produced in each urine sample by a bioluminescence reaction of the free bacterial adenosine triphosphate with the luciferase-luciferin mixture. The light measured is proportional to the concentration of bacterial adenosine triphosphate which, in turn, is proportional to the number of bacteria present in the respective urine sample.

  5. Constant-Distance Mode Nanospray Desorption Electrospray Ionization Mass Spectrometry Imaging of Biological Samples with Complex Topography

    Energy Technology Data Exchange (ETDEWEB)

    Nguyen, Son N.; Liyu, Andrey V.; Chu, Rosalie K.; Anderton, Christopher R.; Laskin, Julia

    2017-01-17

    A new approach for constant distance mode mass spectrometry imaging of biological samples using nanospray desorption electrospray ionization (nano-DESI MSI) was developed by integrating a shear-force probe with nano-DESI probe. The technical concept and basic instrumental setup as well as general operation of the system are described. Mechanical dampening of resonant oscillations due to the presence of shear forces between the probe and the sample surface enables constant-distance imaging mode via a computer controlled closed feedback loop. The capability of simultaneous chemical and topographic imaging of complex biological samples is demonstrated using living Bacillus Subtilis ATCC 49760 colonies on agar plates. The constant-distance mode nano-DESI MSI enabled imaging of many metabolites including non-ribosomal peptides (surfactin, plipastatin and iturin) and iron-bound heme on the surface of living bacterial colonies ranging in diameter from 10 mm to 13 mm with height variations of up to 0.8 mm above the agar plate. Co-registration of ion images to topographic images provided higher-contrast images. Constant-mode nano-DESI MSI is ideally suited for imaging biological samples of complex topography in their native state.

  6. Nitrous oxide determination in postmortem biological samples: a case of serial fatal poisoning in a public hospital.

    Science.gov (United States)

    Poli, Diana; Gagliano-Candela, Roberto; Strisciullo, Giuseppe; Colucci, Anna P; Strada, Luigi; Laviola, Domenica; Goldoni, Matteo; Mutti, Antonio

    2010-01-01

    In a public hospital, eight cases of fatal poisoning by nitrous oxide (N(2)O) occurred under oxygen administration, due to an erroneous swapping of the lines in the gas system. The aim of the study was to clarify the factors involved in asphyxia by characterizing gases from different lines and measuring N(2)O concentrations in postmortem biological samples from bodies exhumed. Analyses carried out on the gas system confirmed the erroneous substitution of O(2) line with N(2)O and air line with O(2). Consequently, high N(2)O amounts were revealed in several tissues and gaseous biological samples. All specimens were analyzed by headspace gas chromatography technique. A rigorous quantitative analysis was possible only in blood (11.29-2152.04 mg/L) and urine (95.11 mg/L) and in air samples from stomach and trachea (from 5.28 to 83.63 g/m(3)). This study demonstrates that N(2)O can be detected in biological samples even 1 month after death.

  7. Survey of Biology Capstone Courses in American and Canadian Higher Education: Requirement, Content, and Skills

    Science.gov (United States)

    Haave, Neil C.

    2015-01-01

    Capstone experiences have high educational impact with various approaches available for biology. However, no information exists regarding the pervasiveness of capstone courses in Canadian and American biology programs. This study surveyed the prevalence and character of biology capstone courses in the USA and Canada. The survey included a majority…

  8. How Parents Influence School Grades: Hints from a Sample of Adoptive and Biological Families

    Science.gov (United States)

    Johnson, Wendy; McGue, Matt; Iacono, William G.

    2007-01-01

    Using the biological and adoptive families in the Minnesota-based Sibling Interaction and Behavior Study, we investigated the associations among genetic and environmental influences on IQ, parenting, parental expectations for offspring educational attainment, engagement in school, and school grades. All variables showed substantial genetic…

  9. Microwave-ultrasound combined reactor suitable for atmospheric sample preparation procedure of biological and chemical products

    NARCIS (Netherlands)

    Lagha, A.; Chemat, S.; Bartels, P.V.; Chemat, F.

    1999-01-01

    A compact apparatus in which a specific position can be irradiated by microwaves (MW) and ultrasound (US) simultaneously has been developed. The MW-US reactor has been designed for atmospheric pressure digestion and dissolution of biological and chemical products. The reactor can treat a range of th

  10. A high performance liquid chromatographic method of analysis of 4'-O-tetrahydropyranyladriamycin and their metabolites in biological samples.

    Science.gov (United States)

    Matsushita, Y; Iguchi, H; Kiyosaki, T; Tone, H; Ishikura, T; Takeuchi, T; Umezawa, H

    1983-07-01

    A method for measuring 4'-O-tetrahydropyranyladriamycin (THP) and its metabolites in biological samples are described. By reversed-phase high performance liquid chromatography using fluorescence detection, THP and its metabolites were all separated on a single chromatogram within 18 minutes. A linear calibration curve was obtained up to 2,000 ng/ml of THP in plasma. The recovery of THP in the analysis was more than 95% above 5 ng/ml and 87.1% even at 1.25 ng/ml. Thus the lower limit was 1.25 ng/ml in biological samples. Blood levels and urinary excretion in mice and dogs were satisfactory measured by this analytical method.

  11. A 96-well screen filter plate for high-throughput biological sample preparation and LC-MS/MS analysis.

    Science.gov (United States)

    Peng, Sean X; Cousineau, Martin; Juzwin, Stephen J; Ritchie, David M

    2006-01-01

    A novel 96-well screen filter plate (patent pending) has been invented to eliminate a time-consuming and labor-intensive step in preparation of in vivo study samples--to remove blood or plasma clots. These clots plug the pipet tips during a manual or automated sample-transfer step causing inaccurate pipetting or total pipetting failure. Traditionally, these blood and plasma clots are removed by picking them out manually one by one from each sample tube before any sample transfer can be made. This has significantly slowed the sample preparation process and has become a bottleneck for automated high-throughput sample preparation using robotic liquid handlers. Our novel screen filter plate was developed to solve this problem. The 96-well screen filter plate consists of 96 stainless steel wire-mesh screen tubes connected to the 96 openings of a top plate so that the screen filter plate can be readily inserted into a 96-well sample storage plate. Upon insertion, the blood and plasma clots are excluded from entering the screen tube while clear sample solutions flow freely into it. In this way, sample transfer can be easily completed by either manual or automated pipetting methods. In this report, three structurally diverse compounds were selected to evaluate and validate the use of the screen filter plate. The plasma samples of these compounds were transferred and processed in the presence and absence of the screen filter plate and then analyzed by LC-MS/MS methods. Our results showed a good agreement between the samples prepared with and without the screen filter plate, demonstrating the utility and efficiency of this novel device for preparation of blood and plasma samples. The device is simple, easy to use, and reusable. It can be employed for sample preparation of other biological fluids that contain floating particulates or aggregates.

  12. An Activity To Demonstrate the Concept of Sampling Error for the Introductory Biology Classroom.

    Science.gov (United States)

    Rutledge, Michael L.

    2001-01-01

    This activity makes students a part of an investigation that determines the frequency of a particular plant variety in a simulated population. Provides an opportunity for students to observe the inherent variability of estimates, observe the relationship between sample size and sampling error, and consider aspects of research design. (Author/SAH)

  13. Environmental Sampling Procedures and Methods to Respond to Biological Contamination (White Powder)

    Energy Technology Data Exchange (ETDEWEB)

    Piepel, Gregory F.; Amidan, Brett G.; Matzke, Brett D.

    2008-11-01

    This is a contribution to the annual report for the DHS Standards Office. It summarizes statistics-focused work associated with developing validated sampling procedures and methods. The main focus is on the experimental and sampling design constructed for contamination and decontamination field tests conducted during September 2007 in a remote, unused office building on the Idaho National Laboratory site.

  14. The Constitutive Content of the Crime of Refusal or Evasion from Collecting Biological Samples According to the New Criminal Code

    OpenAIRE

    Minodora-Ioana BALAN-RUSU

    2014-01-01

    The purpose and the objectives of the research consist of examining the constitutive content of the crime of refusal or evasion from collecting biological samples according to the New Criminal Code, thus presenting some recent examples of judicial practice that may be applied in terms of new regulations imposed by the entry into force of the New Romanian Criminal Code. The research results consist of examining the constitutive content referring to judicial practice, and highlig...

  15. Prospects of use of cobalt nitrate as a contrast medium in electron microscopy of biological samples

    Directory of Open Access Journals (Sweden)

    I. O. Tikhankov

    2008-01-01

    Full Text Available The method of cobalt nitrate impregnation of ultrathin sections of plant and animal tissues, which are embedded in epoxy resin, has been worked out. Various aspects of such handling of specimens have been examined. Best conditions for the sections staining were determined. The advantage of this method was analyzed. The estimation of the possibilities to implicate this method for the morphological and histochemical study of various biological specimens has been made.

  16. Evaluation of cadmium, lead, nickel and zinc status in biological samples of smokers and nonsmokers hypertensive patients.

    Science.gov (United States)

    Afridi, H I; Kazi, T G; Kazi, N G; Jamali, M K; Arain, M B; Sirajuddin; Baig, J A; Kandhro, G A; Wadhwa, S K; Shah, A Q

    2010-01-01

    The objective of this study was to evaluate the association between trace and toxic elements zinc (Zn), cadmium (Cd), nickel (Ni) and lead (Pb) in biological samples (scalp hair, blood and urine) of smoker and nonsmoker hypertensive patients (n=457), residents of Hyderabad, Pakistan. For the purpose of comparison, the biological samples of age-matched healthy controls were selected as referents. The concentrations of trace and toxic elements were measured by atomic absorption spectrophotometer prior to microwave-assisted acid digestion. The validity and accuracy of the methodology were checked using certified reference materials and by the conventional wet acid digestion method on the same certified reference materials and real samples. The recovery of all the studied elements was found to be in the range of 97.8-99.3% in certified reference materials. The results of this study showed that the mean values of Cd, Ni and Pb were significantly higher in scalp hair, blood and urine samples of both smoker and nonsmoker patients than in referents (P<0.001), whereas the concentration of Zn was lower in the scalp hair and blood, but higher in the urine samples of hypertensive patients. The deficiency of Zn and the high exposure of toxic metals as a result of tobacco smoking may be synergistic with risk factors associated with hypertension.

  17. A high-performance direct transmethylation method for total fatty acids assessment in biological and foodstuff samples.

    Science.gov (United States)

    Castro-Gómez, Pilar; Fontecha, Javier; Rodríguez-Alcalá, Luis M

    2014-10-01

    Isolation is the main bottleneck in the analysis of fatty acids in biological samples and foods. In the last few decades some methods described direct derivatization procedures bypassing these steps. They involve the utilization of methanolic HCL or BF3 as catalysts, but several evidences from previous works suggest these reagents are unstable, lead to the formation of artifacts and alter the distribution of specific compounds as hydroxy fatty acids or CLA. However, the main issue is that they are excellent esterification reagents but poor in transterification, being not suitable for the analysis of all lipid classes and leading to erroneous composition quantitations. The present research work is a comprehensive comparison of six general methylation protocols using base, acid or base/acid catalysts plus a proposed method in the analysis of total fatty acids in lipid standards mixtures, foodstuff and biological samples. The addition of aprotic solvents to the reaction mixture to avoid alterations was also tested. Results confirmed that procedures solely involving acid catalyst resulted in incomplete derivatizations and alteration of the fatty acid profile, partially corrected by addition of the aprotic solvent. The proposed method combining sodium methoxyde and sulfuric acid showed absence of alteration of the FAME profile and the best values for response factors (short chain fatty acids to PUFA), accuracy in the determination of total cholesterol and derivatization performance, thus showing a high reliability in the determination of the total fatty acid composition in biological samples and foods.

  18. Capillary zone electrophoresis for analysis of phytochelatins and other thiol peptides in complex biological samples derivatized with monobromobimane.

    Science.gov (United States)

    Perez-Rama, Mónica; Torres Vaamonde, Enrique; Abalde Alonso, Julio

    2005-02-01

    A new method to improve the analysis of phytochelatins and their precursors (cysteine, gamma-Glu-Cys, and glutathione) derivatized with monobromobimane (mBrB) in complex biological samples by capillary zone electrophoresis is described. The effects of the background electrolyte pH, concentration, and different organic additives (acetonitrile, methanol, and trifluoroethanol) on the separation were studied to achieve optimum resolution and number of theoretical plates of the analyzed compounds in the electropherograms. Optimum separation of the thiol peptides was obtained with 150 mM phosphate buffer at pH 1.60. Separation efficiency was improved when 2.5% v/v methanol was added to the background electrolyte. The electrophoretic conditions were 13 kV and capillary dimensions with 30 cm length from the inlet to the detector (38 cm total length) and 50 microm inner diameter. The injection was by pressure at 50 mbar for 17 s. Under these conditions, the separation between desglycyl-peptides and phytochelatins was also achieved. We also describe the optimum conditions for the derivatization of biological samples with mBrB to increase electrophoretic sensitivity and number of theoretical plates. The improved method was shown to be simple, reproducible, selective, and accurate in measuring thiol peptides in complex biological samples, the detection limit being 2.5 microM glutathione at a wavelength of 390 nm.

  19. Active learning not associated with student learning in a random sample of college biology courses.

    Science.gov (United States)

    Andrews, T M; Leonard, M J; Colgrove, C A; Kalinowski, S T

    2011-01-01

    Previous research has suggested that adding active learning to traditional college science lectures substantially improves student learning. However, this research predominantly studied courses taught by science education researchers, who are likely to have exceptional teaching expertise. The present study investigated introductory biology courses randomly selected from a list of prominent colleges and universities to include instructors representing a broader population. We examined the relationship between active learning and student learning in the subject area of natural selection. We found no association between student learning gains and the use of active-learning instruction. Although active learning has the potential to substantially improve student learning, this research suggests that active learning, as used by typical college biology instructors, is not associated with greater learning gains. We contend that most instructors lack the rich and nuanced understanding of teaching and learning that science education researchers have developed. Therefore, active learning as designed and implemented by typical college biology instructors may superficially resemble active learning used by education researchers, but lacks the constructivist elements necessary for improving learning.

  20. Metabolomics identifies a biological response to chronic low-dose natural uranium contamination in urine samples.

    Science.gov (United States)

    Grison, Stéphane; Favé, Gaëlle; Maillot, Matthieu; Manens, Line; Delissen, Olivia; Blanchardon, Eric; Banzet, Nathalie; Defoort, Catherine; Bott, Romain; Dublineau, Isabelle; Aigueperse, Jocelyne; Gourmelon, Patrick; Martin, Jean-Charles; Souidi, Maâmar

    2013-01-01

    Because uranium is a natural element present in the earth's crust, the population may be chronically exposed to low doses of it through drinking water. Additionally, the military and civil uses of uranium can also lead to environmental dispersion that can result in high or low doses of acute or chronic exposure. Recent experimental data suggest this might lead to relatively innocuous biological reactions. The aim of this study was to assess the biological changes in rats caused by ingestion of natural uranium in drinking water with a mean daily intake of 2.7 mg/kg for 9 months and to identify potential biomarkers related to such a contamination. Subsequently, we observed no pathology and standard clinical tests were unable to distinguish between treated and untreated animals. Conversely, LC-MS metabolomics identified urine as an appropriate biofluid for discriminating the experimental groups. Of the 1,376 features detected in urine, the most discriminant were metabolites involved in tryptophan, nicotinate, and nicotinamide metabolic pathways. In particular, N-methylnicotinamide, which was found at a level seven times higher in untreated than in contaminated rats, had the greatest discriminating power. These novel results establish a proof of principle for using metabolomics to address chronic low-dose uranium contamination. They open interesting perspectives for understanding the underlying biological mechanisms and designing a diagnostic test of exposure.

  1. Measurement frequency and sampling spatial domains required to characterize turbidity and salinity events in the Guadalquivir estuary (Spain

    Directory of Open Access Journals (Sweden)

    E. Contreras

    2012-08-01

    Full Text Available Estuaries are complex systems in which long water quality data series are not always available at the proper scale. Data proceeding from several water quality networks, with different measuring frequencies (monthly, weekly and 15 min and different numbers of sampling points, were compared throughout the main channel of the Guadalquivir estuary. Higher frequency of turbidity sampling in the upper estuary is required. In the lower estuary, sampling points help to find out the ETM, and higher frequency sampling of EC is required because of the effect of the tidal and river components. This could be a feedback for the implementation of monitoring networks in estuaries.

  2. Automatic sampling for unbiased and efficient stereological estimation using the proportionator in biological studies

    DEFF Research Database (Denmark)

    Gardi, Jonathan Eyal; Nyengaard, Jens Randel; Gundersen, Hans Jørgen Gottlieb

    2008-01-01

    cerebellum, total number of orexin positive neurons in transgenic mice brain, and estimating the absolute area and the areal fraction of β islet cells in dog pancreas.  The proportionator was at least eight times more efficient (precision and time combined) than traditional computer controlled sampling.......Quantification of tissue properties is improved using the general proportionator sampling and estimation procedure: automatic image analysis and non-uniform sampling with probability proportional to size (PPS). The complete region of interest is partitioned into fields of view, and every field...

  3. Fluorometric quantification of protoporphyrin IX in biological skin samples from in vitro penetration/permeation studies

    Directory of Open Access Journals (Sweden)

    Fábia Cristina Rossetti

    2010-12-01

    Full Text Available A fluorometric analytical method was developed for quantification of protoporphyrin IX (PpIX in skin samples and receptor phase solution after in vitro cutaneous penetration/permeation studies. Analytical conditions used were: excitation and emission wavelengths: 400 nm and 632 nm; bandwidth: 0.5 nm; excitation and emission slits: 10/10. PpIX was recovered from two different layers of skin, the stratum corneum (SC and the epidermis plus dermis ([E+D], by vortex homogenization, probe and bath sonication, using DMSO as an extraction solvent. The detection and quantification limits were 0.002 and 0.005 μg/mL, respectively. The assay was linear from 0.005 - 0.5 μg/mL. The within-day and between-day assay precision and accuracy in DMSO and receptor phase solution were each studied at the two concentration levels 0.04 and 0.2 μg/mL, and 0.01 and 0.08 μg/mL, respectively. The coefficients of variation and deviation from the theoretical values were lower than 5%. The skin recovery of PpIX from SC and [E+D] layers using two different concentrations (0.5 and 1.0 μg/mL were all above 90.0%. The method described has potential application to in vitro penetration/permeation studies of PpIX using porcine skin as a biological membrane model.Um método analítico por espectrofluorimetria foi desenvolvido para quantificar a protoporfirina IX (Pp IX em amostras de pele e fase receptora após a realização de testes in vitro de penetração/permeação cutâneas. As condições analíticas utilizadas foram: comprimentos de onda de excitação e emissão: 400 nm e 632 nm; largura de banda: 0,5 nm; fendas de excitação e emissão: 10/10. A PpIX foi extraída de amostras de estrato córneo (EC e da epiderme sem estrato córneo + derme ([E+D] através da agitação em vórtex e sonicação por haste e banho, utilizando-se o DMSO como solvente extrator. O limite de detecção e quantificação foram, respectivamente, de 0,002 e 0,005 μg/mL. O método mostrou

  4. Biologic

    CERN Document Server

    Kauffman, L H

    2002-01-01

    In this paper we explore the boundary between biology and the study of formal systems (logic). In the end, we arrive at a summary formalism, a chapter in "boundary mathematics" where there are not only containers but also extainers ><, entities open to interaction and distinguishing the space that they are not. The boundary algebra of containers and extainers is to biologic what boolean algebra is to classical logic. We show how this formalism encompasses significant parts of the logic of DNA replication, the Dirac formalism for quantum mechanics, formalisms for protein folding and the basic structure of the Temperley Lieb algebra at the foundations of topological invariants of knots and links.

  5. Environmental contaminants in water, sediment and biological samples from Playa Lakes in southeastern New Mexico - 1992

    Data.gov (United States)

    US Fish and Wildlife Service, Department of the Interior — Sediment, water, bird tissue, and invertebrates were collected from 10 playa lakes in Southeastern New Mexico in 1991 and 1992. These samples were analyzed for a...

  6. Oxygen bomb combustion of biological samples for inductively coupled plasma optical emission spectrometry

    Science.gov (United States)

    Souza, Gilberto B.; Carrilho, Elma Neide V. M.; Oliveira, Camila V.; Nogueira, Ana Rita A.; Nóbrega, Joaquim A.

    2002-12-01

    A rapid sample preparation method is proposed for decomposition of milk powder, corn bran, bovine and fish tissues, containing certified contents of the analytes. The procedure involves sample combustion in a commercial stainless steel oxygen bomb operating at 25 bar. Most of the samples were decomposed within 5 min. Diluted nitric acid or water-soluble tertiary amines 10% v/v were used as absorption solutions. Calcium, Cu, K, Mg, Na, P, S and Zn were recovered with the bomb washings and determined by inductively coupled plasma optical emission spectrometry (ICP-OES). Ethanol mixed with paraffin was used as a combustion aid to allow complete combustion. A cooling step prior releasing of the bomb valve was employed to increase the efficiency of sample combustion. Iodine was also determined in milk samples spiked with potassium iodide to evaluate the volatilization and collection of iodine in amine CFA-C medium and the feasibility of its determination by ICP-OES with axial view configuration. Most of the element recoveries in the samples were between 91 and 105% and the certified and found contents exhibited a fair agreement at a 95% confidence level.

  7. Ultrasound-air-assisted demulsified liquid-liquid microextraction by solidification of a floating organic droplet for determination of three antifungal drugs in water and biological samples.

    Science.gov (United States)

    Ezoddin, Maryam; Shojaie, Mehran; Abdi, Khosrou; Karimi, Mohammad Ali

    2017-03-01

    A novel ultrasound-air-assisted demulsified liquid-liquid microextraction by solidification of a floating organic droplet (UAAD-LLM-SFO) followed by HPLC-UV detection was developed for the analysis of three antifungal drugs in water and biological samples. In this method, 1-dodecanol was used as the extraction solvent. The emulsion was rapidly formed by pulling in and pushing out the mixture of sample solution and extraction solvent for 5 times repeatedly using a 10-mL glass syringe while sonication was performed. Therefore, an organic dispersive solvent required in common microextraction methods was not used in the proposed method. After dispersing, an aliquot of acetonitrile was introduced as a demulsifier solvent into the sample solution to separate two phases. Therefore, some additional steps, such as the centrifugation, ultrasonication, or agitation of the sample solution, are not needed. Parameters influencing the extraction recovery were investigated. The proposed method showed a good linearity for the three antifungal drugs studied with the correlation coefficients (R (2) > 0.9995). The limits of detection (LODs) and the limits of the quantification (LOQs) were between 0.01-0.03 μg L(-1) and 0.03-0.08 μg L(-1), respectively. The preconcentration factors (PFs) were in the range of 107-116, respectively. The precisions, as the relative standard deviations (RSDs) (n = 5), for inter-day and intra-day analysis were in the range of 2.1-4.5% and 6.5-8.5%, respectively. This method was successfully applied to determine the three antifungal drugs in tap water and biological samples. The recoveries of antifungal drugs in these samples were 92.4-98.5%. Graphical abstract Ultrasound-air-assisted demulsified liquid-liquid microextraction by solidification of a floating organic droplet for the analysis of three antifungal drugs prior HPLC-UV.

  8. Systematic approach to optimize a pretreatment method for ultrasensitive liquid chromatography with tandem mass spectrometry analysis of multiple target compounds in biological samples.

    Science.gov (United States)

    Togashi, Kazutaka; Mutaguchi, Kuninori; Komuro, Setsuko; Kataoka, Makoto; Yamazaki, Hiroshi; Yamashita, Shinji

    2016-08-01

    In current approaches for new drug development, highly sensitive and robust analytical methods for the determination of test compounds in biological samples are essential. These analytical methods should be optimized for every target compound. However, for biological samples that contain multiple compounds as new drug candidates obtained by cassette dosing tests, it would be preferable to develop a single method that allows the determination of all compounds at once. This study aims to establish a systematic approach that enables a selection of the most appropriate pretreatment method for multiple target compounds without the use of their chemical information. We investigated the retention times of 27 known compounds under different mobile phase conditions and determined the required pretreatment of human plasma samples using several solid-phase and liquid-liquid extractions. From the relationship between retention time and recovery in a principal component analysis, appropriate pretreatments were categorized into several types. Based on the category, we have optimized a pretreatment method for the identification of three calcium channel blockers in human plasma. Plasma concentrations of these drugs in a cassette-dose clinical study at microdose level were successfully determined with a lower limit of quantitation of 0.2 pg/mL for diltiazem, 1 pg/mL for nicardipine, and 2 pg/mL for nifedipine.

  9. Sampling strategies and post-processing methods for increasing the time resolution of organic aerosol measurements requiring long sample-collection times

    Science.gov (United States)

    Modini, Rob L.; Takahama, Satoshi

    2016-07-01

    The composition and properties of atmospheric organic aerosols (OAs) change on timescales of minutes to hours. However, some important OA characterization techniques typically require greater than a few hours of sample-collection time (e.g., Fourier transform infrared (FTIR) spectroscopy). In this study we have performed numerical modeling to investigate and compare sample-collection strategies and post-processing methods for increasing the time resolution of OA measurements requiring long sample-collection times. Specifically, we modeled the measurement of hydrocarbon-like OA (HOA) and oxygenated OA (OOA) concentrations at a polluted urban site in Mexico City, and investigated how to construct hourly resolved time series from samples collected for 4, 6, and 8 h. We modeled two sampling strategies - sequential and staggered sampling - and a range of post-processing methods including interpolation and deconvolution. The results indicated that relative to the more sophisticated and costly staggered sampling methods, linear interpolation between sequential measurements is a surprisingly effective method for increasing time resolution. Additional error can be added to a time series constructed in this manner if a suboptimal sequential sampling schedule is chosen. Staggering measurements is one way to avoid this effect. There is little to be gained from deconvolving staggered measurements, except at very low values of random measurement error (< 5 %). Assuming 20 % random measurement error, one can expect average recovery errors of 1.33-2.81 µg m-3 when using 4-8 h-long sequential and staggered samples to measure time series of concentration values ranging from 0.13-29.16 µg m-3. For 4 h samples, 19-47 % of this total error can be attributed to the process of increasing time resolution alone, depending on the method used, meaning that measurement precision would only be improved by 0.30-0.75 µg m-3 if samples could be collected over 1 h instead of 4 h. Devising a

  10. Supercritical fluid extraction and ultra performance liquid chromatography of respiratory quinones for microbial community analysis in environmental and biological samples.

    Science.gov (United States)

    Hanif, Muhammad; Atsuta, Yoichi; Fujie, Koichi; Daimon, Hiroyuki

    2012-03-05

    Microbial community structure plays a significant role in environmental assessment and animal health management. The development of a superior analytical strategy for the characterization of microbial community structure is an ongoing challenge. In this study, we developed an effective supercritical fluid extraction (SFE) and ultra performance liquid chromatography (UPLC) method for the analysis of bacterial respiratory quinones (RQ) in environmental and biological samples. RQ profile analysis is one of the most widely used culture-independent tools for characterizing microbial community structure. A UPLC equipped with a photo diode array (PDA) detector was successfully applied to the simultaneous determination of ubiquinones (UQ) and menaquinones (MK) without tedious pretreatment. Supercritical carbon dioxide (scCO(2)) extraction with the solid-phase cartridge trap proved to be a more effective and rapid method for extracting respiratory quinones, compared to a conventional organic solvent extraction method. This methodology leads to a successful analytical procedure that involves a significant reduction in the complexity and sample preparation time. Application of the optimized methodology to characterize microbial communities based on the RQ profile was demonstrated for a variety of environmental samples (activated sludge, digested sludge, and compost) and biological samples (swine and Japanese quail feces).

  11. Supercritical Fluid Extraction and Ultra Performance Liquid Chromatography of Respiratory Quinones for Microbial Community Analysis in Environmental and Biological Samples

    Directory of Open Access Journals (Sweden)

    Koichi Fujie

    2012-03-01

    Full Text Available Microbial community structure plays a significant role in environmental assessment and animal health management. The development of a superior analytical strategy for the characterization of microbial community structure is an ongoing challenge. In this study, we developed an effective supercritical fluid extraction (SFE and ultra performance liquid chromatography (UPLC method for the analysis of bacterial respiratory quinones (RQ in environmental and biological samples. RQ profile analysis is one of the most widely used culture-independent tools for characterizing microbial community structure. A UPLC equipped with a photo diode array (PDA detector was successfully applied to the simultaneous determination of ubiquinones (UQ and menaquinones (MK without tedious pretreatment. Supercritical carbon dioxide (scCO2 extraction with the solid-phase cartridge trap proved to be a more effective and rapid method for extracting respiratory quinones, compared to a conventional organic solvent extraction method. This methodology leads to a successful analytical procedure that involves a significant reduction in the complexity and sample preparation time. Application of the optimized methodology to characterize microbial communities based on the RQ profile was demonstrated for a variety of environmental samples (activated sludge, digested sludge, and compost and biological samples (swine and Japanese quail feces.

  12. Measurement of the unstained biological sample by a novel scanning electron generation X-ray microscope based on SEM.

    Science.gov (United States)

    Ogura, Toshihiko

    2009-08-01

    We introduced a novel X-ray microscope system based on scanning electron microscopy using thin film, which enables the measurement of unstained biological samples without damage. An unstained yeast sample was adsorbed under a titanium (Ti)-coated silicon nitride (Si3N4) film 90 nm thick. The X-ray signal from the film was detected by an X-ray photodiode (PD) placed below the sample. With an electron beam at 2.6 kV acceleration and 6.75 nA current, the yeast image is obtained using the X-ray PD. The image is created by soft X-rays from the Ti layer. The Ti layer is effective in generating the characteristic 2.7-nm wavelength X-rays by the irradiation of electrons. Furthermore, we investigated the electron trajectory and the generation of the characteristic X-rays within the Ti-coated Si3N4 film by Monte Carlo simulation. Our system can be easily utilized to observe various unstained biological samples of cells, bacteria, and viruses.

  13. The biology and thermal requirements of the fennel aphid Hyadaphis foeniculi (Passerini (Hemiptera: Aphididae.

    Directory of Open Access Journals (Sweden)

    José B Malaquias

    Full Text Available The relationship between the insect development rate and temperature was established very early and represents an important ecological variable for modeling the population dynamics of insects. The accurate determination of thermal constant values and the lower and upper developmental thresholds of Hyadaphis foeniculi (Passerini (Hemiptera: Aphididae on fennel (Foeniculum vulgare Miller (Apiales: Apiaceae crops would obviously benefit the effective application of control measures. This paper is a study of the biology and thermal requirements of H. foeniculi. Winged insects were collected from fennel crops at the Embrapa Algodão in Campina Grande, Paraíba. Nymphs (age ≤24 h produced by winged insects were subjected to constant temperatures of 15, 20, 25, 28, 30 or 33°C, a photophase of 12 h and a relative humidity of 70±10%. The results of the study showed that at temperatures between 15 and 30°C, H. foeniculi nymphs were able to develop normally. The four instars were found at all temperatures tested. However, temperatures of 3 and 33°C were lethal to the nymphs. The nymph stage development time varied from 5 (30°C to 19 (15°C days. The influence of temperature on the development time is dependent on the instar. The base temperature (Tb and the thermal constant (K for the nymph stage were estimated at 11.2°C and 107.5 degree-days, respectively. The shortest nymph development stage was observed at 30°C, and the highest nymph viability (85.0% was observed at 28°C. This information can be used for developing phenological models based on the temperature and development rate relationships so that outbreaks of H. foeniculi in the fennel crop can be predicted, therefore improving the application of control programs targeting this fennel pest.

  14. The biology and thermal requirements of the fennel aphid Hyadaphis foeniculi (Passerini) (Hemiptera: Aphididae).

    Science.gov (United States)

    Malaquias, José B; Ramalho, Francisco S; Lira, Aline C S; Oliveira, Flávia Q; Fernandes, Francisco S; Godoy, Wesley A C; Zanuncio, José C

    2014-01-01

    The relationship between the insect development rate and temperature was established very early and represents an important ecological variable for modeling the population dynamics of insects. The accurate determination of thermal constant values and the lower and upper developmental thresholds of Hyadaphis foeniculi (Passerini) (Hemiptera: Aphididae) on fennel (Foeniculum vulgare Miller (Apiales: Apiaceae)) crops would obviously benefit the effective application of control measures. This paper is a study of the biology and thermal requirements of H. foeniculi. Winged insects were collected from fennel crops at the Embrapa Algodão in Campina Grande, Paraíba. Nymphs (age ≤24 h) produced by winged insects were subjected to constant temperatures of 15, 20, 25, 28, 30 or 33°C, a photophase of 12 h and a relative humidity of 70±10%. The results of the study showed that at temperatures between 15 and 30°C, H. foeniculi nymphs were able to develop normally. The four instars were found at all temperatures tested. However, temperatures of 3 and 33°C were lethal to the nymphs. The nymph stage development time varied from 5 (30°C) to 19 (15°C) days. The influence of temperature on the development time is dependent on the instar. The base temperature (Tb) and the thermal constant (K) for the nymph stage were estimated at 11.2°C and 107.5 degree-days, respectively. The shortest nymph development stage was observed at 30°C, and the highest nymph viability (85.0%) was observed at 28°C. This information can be used for developing phenological models based on the temperature and development rate relationships so that outbreaks of H. foeniculi in the fennel crop can be predicted, therefore improving the application of control programs targeting this fennel pest.

  15. Development of a radioimmunoassay for the determination of buprenorphine in biological samples

    Energy Technology Data Exchange (ETDEWEB)

    Debrabandere, L.; Boven, M. Van; Daenens, P. (Louvain Univ. (Belgium))

    1993-02-01

    The development of a specific and sensitive radioimmunoassay for the detection of buprenorphine in urine samples is described. With minor adjustments, the assay was also applied to the analysis for buprenorphine in plasma samples. The 2-diazobenzoic acid derivative of buprenorphine has been prepared as a hapten. The immunization of rabbits with the hapten-bovine serum albumin conjugate resulted in the production of antibodies, which cross-reacted with N-dealkylbuprenophine up to about the 90% level. The antibodies showed very low cross-reactivities with the 3-O-glucuronides and with the structural analogue etorphine. The assay was mainly used to prescreen for buprenorphine in urine samples of persons suspected of Temgesic misuse and to determine buprenorphine in plasma samples. A linear calibration graph for buprenorphine was obtained after logit-log regression. The spiking recovery study showed a linear regression. Intra-and inter-assay relative standard deviations were < 4.35 and < 6.36%, respectively. A comparison study of the high-performance liquid chromatographic determination (X) to the radioimmunoassay (Y) resulted in the following regression equation for the urine samples: Y = 1.44 + 1.64 X (n = 32; r 0.910) and Y = 0.007 + 1.58 X (n = 10; r = 0.930) for plasma specimens. The minimum detectable dose of the immunoassay was calculated to be 10 pg ml[sup -1] (Student's t-distribution, p 0.01, degrees of freedom = 8). (Author).

  16. Diffraction enhanced imaging and x-ray fluorescence microtomography for analyzing biological samples

    Energy Technology Data Exchange (ETDEWEB)

    Rocha, H.S.; Pereira, G.R.; Lopes, R.T. [Laboratorio de Instrumentacao Nuclear-COPPE/UFRJ-RJ (Brazil); Anjos, M.J. [Instituto de Fisica-UERJ-RJ (Brazil); Faria, P. [Instituto Nacional do Cancer-INCa-RJ (Brazil); Kellermann, G.; Perez, C.A. [Laboratorio Nacional de Luz Sincrotron-Campinas-SP (Brazil); Tirao, G. [Faculdad de Mat. Astronomia y Fisica (FAMAF), UNC. Cordoba (Argentina); Mazzaro, I. [Laboratorio de Optica de Raios X e Instrumentacao-UFPR-Curitiba-PR (Brazil); Giles, C. [Laboratorio de Cristalografia Aplicada e Raios X-UNICAMP-Campinas-SP (Brazil)

    2007-07-15

    In this work, breast tissue samples were investigated in order to verify the distribution of certain elements by x-ray fluorescence computed tomography (XRFCT) correlated with the characteristics and pathology of each tissue observed by diffraction enhanced imaging (DEI). The DEI system can show details in low attenuation tissues. It is based on the contrast imaging obtained by extinction, diffraction and refraction characteristics and can improve reduction in false positive and false negative diagnoses. XRFCT allows mapping of all elements within the sample, since even a minute fluorescence signal can be detected. DEI imaging techniques revealed the complex structure of the disease, confirmed by the histological section, and showed microstructures in all planes of the sample. The XRFCT showed the distribution of Zn, Cu and Fe at higher concentration. (authors)

  17. Mapping Chemical and Structural Composition of Pharmaceutical and Biological Samples by Raman, Surface-Enhanced Raman and Fluorescence Spectral Imaging

    Science.gov (United States)

    Chourpa, Igor; Cohen-Jonathan, Simone; Dubois, Pierre

    Raman spectroscopy is an analytical technique recognised for its structural and conformational specificity. The efficient discrimination of molecular species by Raman is particularly potent for multidimensional microscopic imaging of complex biological environment, as demonstrated in the present book. The commonly admitted problem of Raman, low sensitivity, can often be circumvented due to high output instruments and via approaches like RRS (resonance Raman scattering), SERS (surface-enhanced Raman scattering), TERS (tip-enhanced Raman scattering) or CARS (coherent anti-Stokes Raman scattering). In contrast to the latter, RRS and SERS are realizable with less sophisticated set-up based on common Raman systems. Although more invasive than RRS, SERS provides better sensitivity and quenching of fluorescence. SERRS (surface-enhanced resonance Raman scattering) spectroscopy can be used in coupling with fluorescence and competes in selectivity and sensitivity with spectrofluorimetry. In the chapter below, we use recent applications made in our group to illustrate the use of Raman and SERRS spectral imaging for characterization of biological samples (animal subcutaneous tissue, human cancer cells) and pharmaceutical samples (microparticles for drug delivery, fibres for wound dressing). After a brief description of experimental details on spectral imaging, the chapter will focus on results concerning (i) biocompatible pharmaceutical materials made of alginates and (ii) anticancer drugs in pharmaceutical forms and in biological systems.

  18. Set-up and calibration of a method to measure 10B concentration in biological samples by neutron autoradiography

    Science.gov (United States)

    Gadan, M. A.; Bortolussi, S.; Postuma, I.; Ballarini, F.; Bruschi, P.; Protti, N.; Santoro, D.; Stella, S.; Cansolino, L.; Clerici, A.; Ferrari, C.; Zonta, A.; Zonta, C.; Altieri, S.

    2012-03-01

    A selective uptake of boron in the tumor is the base of Boron Neutron Capture Therapy, which can destroy the tumor substantially sparing the normal tissue. In order to deliver a lethal dose to the tumor, keeping the dose absorbed by normal tissues below the tolerance level, it is mandatory to know the 10B concentration present in each kind of tissue at the moment of irradiation. This work presents the calibration procedure adopted for a boron concentration measurement method based on neutron autoradiography, where biological samples are deposited on sensitive films and irradiated in the thermal column of the TRIGA reactor (University of Pavia). The latent tracks produced in the film by the charged particles coming from the neutron capture in 10B are made visible by a proper etching, allowing the measurement of the track density. A calibration procedure with standard samples provides curves of track density as a function of boron concentration, to be used in the measurement of biological samples. In this paper, the bulk etch rate parameter and the calibration curves obtained for both liquid samples and biological tissues with known boron concentration are presented. A bulk etch rate value of (1.64 ± 0.02) μm/h and a linear dependence with etching time were found. The plots representing the track density versus the boron concentration in a range between 5 and 50 μg/g (ppm) are linear, with an angular coefficient of (1.614 ± 0.169)·10-3 tracks/(μm2 ppm) for liquids and (1.598 ± 0.097)·10-2 tracks/(μm2 ppm) for tissues.

  19. Is routine karyotyping required in prenatal samples with a molecular or metabolic referral?

    NARCIS (Netherlands)

    Kooper, A.J.A.; Pieters, J.J.; Faas, B.H.W.; Hoefsloot, L.H.; Burgt, C.J.A.M. van der; Zondervan, H.A.; Smits, A.P.T.

    2012-01-01

    ABSTRACT: As a routine, karyotyping of invasive prenatal samples is performed as an adjunct to referrals for DNA mutation detection and metabolic testing. We performed a retrospective study on 500 samples to assess the diagnostic value of this procedure. These samples included 454 (90.8%) chorionic

  20. Biological parameters and thermal requirements of the parasitoid Praon volucre (Hymenoptera: Braconidae) with Macrosiphum euphorbiae (Hemiptera: Aphididae) as host

    NARCIS (Netherlands)

    Conti, De B.F.; Bueno, V.H.P.; Sampaio, M.V.; Lenteren, van J.C.

    2011-01-01

    The effect of temperature on the biology of Praon volucre (Haliday, 1833) (Hymenoptera: Braconidae) in Macrosiphum euphorbiae (Thomas, 1878) (Hemiptera: Aphididae) hosts was studied and the thermal requirements of the parasitoid were determined. Experiments were carried out at 16, 19, 22, 25, and 28

  1. Detection of mutant protein in complex biological samples: Glucocerebrosidase mutations in Gaucher’s disease

    NARCIS (Netherlands)

    Bleijlevens, B.; van Breemen, M.J.; Donker-Koopman, W.E.; de Koster, C.G.; Aerts, J.M.F.G.

    2008-01-01

    We report a sensitive method to detect point mutations in proteins from complex samples. The method is based on surface-enhanced laser desorption/ionization time-of-flight (SELDI-ToF) MS but can be extended to other MS platforms. The target protein in this study is the lysosomal enzyme glucocerebros

  2. Determination of total magnesium in biological samples using electrothermal atomic absorption spectrometry

    Science.gov (United States)

    Hulanicki, Adam; Godlewska, Beata; Brzóska, Malgorzata

    1995-11-01

    Magnesium content is an important diagnostic parameter in medicine. It is recognized that its determination in one compartment is not sufficient for reliable information about the magnesium status in the body. In addition to the common procedures of magnesium determination in blood by flame atomic absorption spectrometry, the procedure of electrothermal atomization has also been developed and applied to the analysis of blood fractions, mononuclear cells and isolated nuclei of liver cells. Electrothermal atomization is preferred in cases where the sample size is limited and the magnesium content low. The total errors are in the order of 3-4%. Various techniques of sample pretreatment have been tested and direct dilution with 0.05 mol l -1 nitric acid was optimal when the samples were not mineralized. The calibration graph based on standards containing albumin was found to give the best results, as the form of magnesium in the samples may influence the ashing and atomization processes. Good agreement was obtained for determination of magnesium in standard serum. The results are compared with those obtained by the standard flame atomization technique.

  3. Comparative quantification of Campylobacter jejuni from environmental samples using traditional and molecular biological techniques.

    Science.gov (United States)

    Rothrock, Michael J; Cook, Kimberly L; Bolster, Carl H

    2009-06-01

    Campylobacter jejuni is one of the most common causes of gastroenteritis in the world. Given the potential risks to human, animal, and environmental health, the development and optimization of methods to quantify this important pathogen in environmental samples is essential. Two of the most commonly used methods for quantifying C. jejuni are selective plate counting and quantitative real-time PCR (qPCR). Unfortunately, little comparative research has been performed to evaluate the accuracy of these methods for quantification of C. jejuni in aqueous and solid matricies. In this study, the limit of detection and the level of resolution obtained using these 2 methods was evaluated for C. jejuni and compared with that of the common indicator organism Escherichia coli. The use of selective plate count media for quantification of C. jejuni resulted in a 0.7-1.2 log underestimation of cell concentrations, compared with qPCR in both water and column leachate samples, whereas E. coli concentrations were found to be similar with either technique. For C. jejuni, only the qPCR assay accurately measured 2-fold changes in cell concentrations in water samples, whereas concentrations of E. coli were accurately measured regardless of method. Based on these data, qPCR assays were found to be more accurate than selective plate counts for quantification of C. jejuni from environmental samples.

  4. Sample Preparation and Identification of Biological, Chemical and Mid-Spectrum Agents

    Science.gov (United States)

    2005-10-01

    substrate molecule is called a hydrolase. Substrates commonly used are sodium hippurate, DNA, urea, esculin, starch , casein, lecithin and polysorbate-80...processed sample are first denatured and separated by gel electrophoresis [usually sodium dodecyl polyacrylamide gel electrophoresis (SDS-PAGE)] and

  5. Contrastive analysis of hedges in a sample of Chinese and English molecular biology papers.

    Science.gov (United States)

    Gao, Xiaofang

    2004-10-01

    Hedge is defined as the expression of provisionalness and possibility that makes scientific messages tentative, vague, and imprecise, thereby reducing the force of claims scientists make. Linguistic study of hedges began in the early 1970s in generative semantics. Since then, the focus has shifted from seeking linguistic properties in spoken discourse to analyzing its pragmatic functions in written contextual communication. The purpose of this paper was to analyze hedges in Chinese and English scientific articles from the perspective of contrastive pragmatics. Based on a contextual analysis of 5 Chinese and 5 English scientific articles, selected randomly, from two journals in molecular biology--Science in China and Proceedings of the National Academy of Sciences of the United States of America, there were significant differences between Chinese and English scientific articles in use of hedges.

  6. Electrophoresis tests on STS-3 and ground control experiments - A basis for future biological sample selections

    Science.gov (United States)

    Morrison, D. R.; Lewis, M. L.

    1982-01-01

    Static zone electrophoresis is an electrokinetic method of separating macromolecules and small particles. However, its application for the isolation of biological cells and concentrated protein solutions is limited by sedimentation and convection. Microgravity eliminates or reduces sedimentation, floatation, and density-driven convection arising from either Joule heating or concentration differences. The advantages of such an environment were first demonstrated in space during the Apollo 14 and 16 missions. In 1975 the Electrophoresis Technology Experiment (MA-011) was conducted during the Apollo-Soyuz Test Project flight. In 1979 a project was initiated to repeat the separations of human kidney cells. One of the major objectives of the Electrophoresis Equipment Verification Tests (EEVT) on STS-3 was to repeat and thereby validate the first successful electrophoretic separation of human kidney cells. Attention is given to the EEVT apparatus, the preflight electrophoresis, and inflight operational results.

  7. Simultaneous determination of trace levels of ethylmercury and methylmercury in biological samples and vaccines using sodium tetra(n-propyl)borate as derivatizing agent.

    Science.gov (United States)

    Gibicar, Darija; Logar, Martina; Horvat, Nusa; Marn-Pernat, Andreja; Ponikvar, Rafael; Horvat, Milena

    2007-05-01

    Because of increasing awareness of the potential neurotoxicity of even low levels of organomercury compounds, analytical techniques are required for determination of low concentrations of ethylmercury (EtHg) and methylmercury (MeHg) in biological samples. An accurate and sensitive method has been developed for simultaneous determination of methylmercury and ethylmercury in vaccines and biological samples. MeHg and EtHg were isolated by acid leaching (H2SO4-KBr-CuSO4), extraction of MeHg and EtHg bromides into an organic solvent (CH2Cl2), then back-extraction into Milli-Q water. MeHg and EtHg bromides were derivatized with sodium tetrapropylborate (NaBPr4), collected at room temperature on Tenax, separated by isothermal gas chromatography (GC), pyrolysed, and detected by cold-vapour atomic fluorescence spectrometry (CV AFS). The repeatability of results from the method was approximately 5-10% for EtHg and 5-15% for MeHg. Detection limits achieved were 0.01 ng g-1 for EtHg and MeHg in blood, saliva, and vaccines and 5 ng g-1 for EtHg and MeHg in hair. The method presented has been shown to be suitable for determination of background levels of these contaminants in biological samples and can be used in studies related to the health effects of mercury and its species in man. This work illustrates the possibility of using hair and blood as potential biomarkers of exposure to thiomersal.

  8. Determination of trace lead in biological and water samples with dispersive liquid-liquid microextraction preconcentration.

    Science.gov (United States)

    Liang, Pei; Sang, Hongbo

    2008-09-01

    A new method for the determination of trace lead was developed by dispersive liquid-liquid microextraction preconcentration and graphite furnace atomic absorption spectrometry. In the proposed approach, 1-phenyl-3-methyl-4-benzoyl-5-pyrazolone (PMBP) was used as a chelating agent, and carbon tetrachloride and ethanol were selected as extraction and dispersive solvents. Some factors influencing the extraction efficiency of lead and its subsequent determination, including extraction and dispersive solvent type and volume, pH of sample solution, concentration of the chelating agent, and extraction time, were studied and optimized. Under the optimum conditions, the enrichment factor of this method for lead was reached at 78. The detection limit for lead was 39 ng L(-1) (3 sigma), and the relative standard deviation (RSD) was 3.2% (n=7, c=10 ng mL(-1)). The method was successfully applied to the determination of trace amounts of lead in human urine and water samples.

  9. Electrochemical Analysis of Antichemotherapeutic Drug Zanosar in Pharmaceutical and Biological Samples by Differential Pulse Polarography

    Directory of Open Access Journals (Sweden)

    Chennupalle Nageswara Reddy

    2013-01-01

    Full Text Available The electrochemical reduction of zanosar was investigated systematically by direct current polarography, cyclic voltammetry, and differential pulse polarography (DPP. A simple DPP technique was proposed for the direct quantitative determination of anticancer drug zanosar in pharmaceutical formulation and spiked human urine samples for the first time. The reduction potential was −0.28 V versus Ag/AgCl with a hanging mercury drop electrode in Britton-Robinson buffer as supporting electrolyte. The dependence of the intensities of currents and potentials on pH, concentration, scan rate, deposition time, and nature of the supporting electrolyte was investigated. The calibration curve was found to be linear with the following equation: y=0.4041x+0.012, with a correlation coefficient of 0.992 (R2 over a concentration range from 1.0×10-7 M to 1.0×10-3 M. In the present investigation, the achieved limit of detection (LOD and limit of quantization (LQD were 7.42×10-8 M and 2.47×10-8 M; respectively. Excipients did not interfere with the determination of zanosar in pharmaceutical formulation and spiked urine samples. Precision and accuracy of the developed method were checked by recovery studies in pharmaceutical formulation and spiked human urine samples.

  10. Label-free quantification of Tacrolimus in biological samples by atomic force microscopy

    Energy Technology Data Exchange (ETDEWEB)

    Menotta, Michele, E-mail: michele.menotta@uniurb.it [Department of Biomolecular Sciences, University of Urbino “Carlo Bo” via Saffi 2, Urbino (Italy); Biagiotti, Sara [Department of Biomolecular Sciences, University of Urbino “Carlo Bo” via Saffi 2, Urbino (Italy); Streppa, Laura [Physics Laboratory, CNRS-ENS, UMR 5672, Lyon (France); Cell and Molecular Biology Laboratory, CNRS-ENS Lyon, UMR 5239, IFR128, Lyon (France); Rossi, Luigia; Magnani, Mauro [Department of Biomolecular Sciences, University of Urbino “Carlo Bo” via Saffi 2, Urbino (Italy)

    2015-07-16

    Highlights: • Tacrolimus is a potent immunosuppressant drug that has to be continually monitored. • We present an atomic force microscope approach for quantification of Tacrolimus in blood samples. • Detection and quantification have been successfully achieved. - Abstract: In the present paper we describe an atomic force microscopy (AFM)-based method for the quantitative analysis of FK506 (Tacrolimus) in whole blood (WB) samples. Current reference methods used to quantify this immunosuppressive drug are based on mass spectrometry. In addition, an immunoenzymatic assay (ELISA) has been developed and is widely used in clinic, even though it shows a small but consistent overestimation of the actual drug concentration when compared with the mass spectrometry method. The AFM biosensor presented herein utilises the endogen drug receptor, FKBP12, to quantify Tacrolimus levels. The biosensor was first assayed to detect the free drug in solution, and subsequently used for the detection of Tacrolimus in blood samples. The sensor was suitable to generate a dose–response curve in the full range of clinical drug monitoring. A comparison with the clinically tested ELISA assay is also reported.

  11. Determination of lead in biological samples of children with different physiological consequences using cloud point extraction method.

    Science.gov (United States)

    Shah, Faheem; Kazi, Tasneem Gul; Ullah, Naeem; Afridi, Hassan Imran

    2013-06-01

    In present study, lead (Pb) level in biological samples of children with physiological disorders (liver, bone, and gastrointestinal; age ranged 1-10 years) have been assessed. For comparison purpose, age-matched healthy children were also selected. Cloud point extraction (CPE) was employed for preconcentration of Pb in acid-digested biological samples prior to its determination by flame atomic absorption spectrometry (FAAS). Dithizone (diphenylthiocarbazone) and nonionic surfactant Triton X-114 (TX-114) were used as complexing reagent and extractant, respectively. The effects of several experimental variables on proposed CPE were evaluated. Under the optimum experimental conditions, the observed detection limit (LOD) and the enhancement factor (EF) were 0.08 μg L(-1) and 53, respectively. Relative standard deviation (RSD) of 10 μg L(-1) Pb was 3.4 %. It was observed that children with liver-, bone-, and gastrointestinal-related disorders had three- to fourfold higher Pb level in blood and scalp hair samples.

  12. Correlation of Arsenic Levels in Smokeless Tobacco Products and Biological Samples of Oral Cancer Patients and Control Consumers.

    Science.gov (United States)

    Arain, Sadaf S; Kazi, Tasneem G; Afridi, Hassan I; Talpur, Farah N; Kazi, Atif G; Brahman, Kapil D; Naeemullah; Panhwar, Abdul H; Kamboh, Muhammad A

    2015-12-01

    It has been extensively reported that chewing of smokeless tobacco (SLT) can lead to cancers of oral cavity. In present study, the relationship between arsenic (As) exposure via chewing/inhaling different SLT products in oral cancer patients have or/not consumed SLT products was studied. The As in different types of SLT products (gutkha, mainpuri, and snuff) and biological (scalp hair and blood) samples of different types of oral cancer patients and controls were analyzed. Both controls and oral cancer patients have same age group (ranged 30-60 years), socio-economic status, localities, and dietary habits. The concentrations of As in SLT products and biological samples were measured by electrothermal atomic absorption spectrophotometer after microwave-assisted acid digestion. The validity and accuracy of the methodology were checked by certified reference materials. The resulted data of present study indicates that the concentration of As was significantly higher in scalp hair and blood samples of oral cancer patients than those of controls (p0.01). The intake of As via consuming different SLT may have synergistic effects, in addition to other risk factors associated with oral cancer.

  13. Development of Experiment Kits for Processing Biological Samples In-Flight on SLS-2

    Science.gov (United States)

    Jaquez, R.; Savage, P. D.; Hinds, W. E.; Evans, J.; Dubrovin, L.

    1994-01-01

    The design of the hematology experiment kits for SLS-2 has resulted in a modular, flexible configuration which maximizes crew efficiency and minimizes error and confusion when dealing with over 1200 different components over the course of the mission. The kit layouts proved to be very easy to use and their packaging design provided for positive, secure containment of the many small components. The secondary Zero(Tm) box enclosure also provided an effective means for transport of the kits within the Spacelab and for grouping individual kits by flight day usage. The kits are readily adaptable to use on future flights by simply replacing the inner components as required and changing the labelling scheme to match new mission requirements.

  14. Computational approaches and metrics required for formulating biologically realistic nanomaterial pharmacokinetic models

    Science.gov (United States)

    Riviere, Jim E.; Scoglio, Caterina; Sahneh, Faryad D.; Monteiro-Riviere, Nancy A.

    2013-01-01

    The field of nanomaterial pharmacokinetics is in its infancy, with major advances largely restricted by a lack of biologically relevant metrics, fundamental differences between particles and small molecules of organic chemicals and drugs relative to biological processes involved in disposition, a scarcity of sufficiently rich and characterized in vivo data and a lack of computational approaches to integrating nanomaterial properties to biological endpoints. A central concept that links nanomaterial properties to biological disposition, in addition to their colloidal properties, is the tendency to form a biocorona which modulates biological interactions including cellular uptake and biodistribution. Pharmacokinetic models must take this crucial process into consideration to accurately predict in vivo disposition, especially when extrapolating from laboratory animals to humans since allometric principles may not be applicable. The dynamics of corona formation, which modulates biological interactions including cellular uptake and biodistribution, is thereby a crucial process involved in the rate and extent of biodisposition. The challenge will be to develop a quantitative metric that characterizes a nanoparticle's surface adsorption forces that are important for predicting biocorona dynamics. These types of integrative quantitative approaches discussed in this paper for the dynamics of corona formation must be developed before realistic engineered nanomaterial risk assessment can be accomplished.

  15. Sample handling in surface sensitive chemical and biological sensing: a practical review of basic fluidics and analyte transport.

    Science.gov (United States)

    Orgovan, Norbert; Patko, Daniel; Hos, Csaba; Kurunczi, Sándor; Szabó, Bálint; Ramsden, Jeremy J; Horvath, Robert

    2014-09-01

    This paper gives an overview of the advantages and associated caveats of the most common sample handling methods in surface-sensitive chemical and biological sensing. We summarize the basic theoretical and practical considerations one faces when designing and assembling the fluidic part of the sensor devices. The influence of analyte size, the use of closed and flow-through cuvettes, the importance of flow rate, tubing length and diameter, bubble traps, pressure-driven pumping, cuvette dead volumes, and sample injection systems are all discussed. Typical application areas of particular arrangements are also highlighted, such as the monitoring of cellular adhesion, biomolecule adsorption-desorption and ligand-receptor affinity binding. Our work is a practical review in the sense that for every sample handling arrangement considered we present our own experimental data and critically review our experience with the given arrangement. In the experimental part we focus on sample handling in optical waveguide lightmode spectroscopy (OWLS) measurements, but the present study is equally applicable for other biosensing technologies in which an analyte in solution is captured at a surface and its presence is monitored. Explicit attention is given to features that are expected to play an increasingly decisive role in determining the reliability of (bio)chemical sensing measurements, such as analyte transport to the sensor surface; the distorting influence of dead volumes in the fluidic system; and the appropriate sample handling of cell suspensions (e.g. their quasi-simultaneous deposition). At the appropriate places, biological aspects closely related to fluidics (e.g. cellular mechanotransduction, competitive adsorption, blood flow in veins) are also discussed, particularly with regard to their models used in biosensing.

  16. Non-target time trend screening: a data reduction strategy for detecting emerging contaminants in biological samples.

    Science.gov (United States)

    Plassmann, Merle M; Tengstrand, Erik; Åberg, K Magnus; Benskin, Jonathan P

    2016-06-01

    Non-targeted mass spectrometry-based approaches for detecting novel xenobiotics in biological samples are hampered by the occurrence of naturally fluctuating endogenous substances, which are difficult to distinguish from environmental contaminants. Here, we investigate a data reduction strategy for datasets derived from a biological time series. The objective is to flag reoccurring peaks in the time series based on increasing peak intensities, thereby reducing peak lists to only those which may be associated with emerging bioaccumulative contaminants. As a result, compounds with increasing concentrations are flagged while compounds displaying random, decreasing, or steady-state time trends are removed. As an initial proof of concept, we created artificial time trends by fortifying human whole blood samples with isotopically labelled standards. Different scenarios were investigated: eight model compounds had a continuously increasing trend in the last two to nine time points, and four model compounds had a trend that reached steady state after an initial increase. Each time series was investigated at three fortification levels and one unfortified series. Following extraction, analysis by ultra performance liquid chromatography high-resolution mass spectrometry, and data processing, a total of 21,700 aligned peaks were obtained. Peaks displaying an increasing trend were filtered from randomly fluctuating peaks using time trend ratios and Spearman's rank correlation coefficients. The first approach was successful in flagging model compounds spiked at only two to three time points, while the latter approach resulted in all model compounds ranking in the top 11 % of the peak lists. Compared to initial peak lists, a combination of both approaches reduced the size of datasets by 80-85 %. Overall, non-target time trend screening represents a promising data reduction strategy for identifying emerging bioaccumulative contaminants in biological samples. Graphical abstract

  17. Applications of High Resolution Laser Induced Breakdown Spectroscopy for Environmental and Biological Samples

    Energy Technology Data Exchange (ETDEWEB)

    Martin, Madhavi Z [ORNL; Labbe, Nicole [ORNL; Wagner, Rebekah J. [Pennsylvania State University, University Park, PA

    2013-01-01

    This chapter details the application of LIBS in a number of environmental areas of research such as carbon sequestration and climate change. LIBS has also been shown to be useful in other high resolution environmental applications for example, elemental mapping and detection of metals in plant materials. LIBS has also been used in phytoremediation applications. Other biological research involves a detailed understanding of wood chemistry response to precipitation variations and also to forest fires. A cross-section of Mountain pine (pinceae Pinus pungen Lamb.) was scanned using a translational stage to determine the differences in the chemical features both before and after a fire event. Consequently, by monitoring the elemental composition pattern of a tree and by looking for abrupt changes, one can reconstruct the disturbance history of a tree and a forest. Lastly we have shown that multivariate analysis of the LIBS data is necessary to standardize the analysis and correlate to other standard laboratory techniques. LIBS along with multivariate statistical analysis makes it a very powerful technology that can be transferred from laboratory to field applications with ease.

  18. Analysis of Turbulence Datasets using a Database Cluster: Requirements, Design, and Sample Applications

    Science.gov (United States)

    Meneveau, Charles

    2007-11-01

    The massive datasets now generated by Direct Numerical Simulations (DNS) of turbulent flows create serious new challenges. During a simulation, DNS provides only a few time steps at any instant, owing to storage limitations within the computational cluster. Therefore, traditional numerical experiments done during the simulation examine each time slice only a few times before discarding it. Conversely, if a few large datasets from high-resolution simulations are stored, they are practically inaccessible to most in the turbulence research community, who lack the cyber resources to handle the massive amounts of data. Even those who can compute at that scale must run simulations again forward in time in order to answer new questions about the dynamics, duplicating computational effort. The result is that most turbulence datasets are vastly underutilized and not available as they should be for creative experimentation. In this presentation, we discuss the desired features and requirements of a turbulence database that will enable its widest access to the research community. The guiding principle of large databases is ``move the program to the data'' (Szalay et al. ``Designing and mining multi-terabyte Astronomy archives: the Sloan Digital Sky Survey,'' in ACM SIGMOD, 2000). However, in the case of turbulence research, the questions and analysis techniques are highly specific to the client and vary widely from one client to another. This poses particularly hard challenges in the design of database analysis tools. We propose a minimal set of such tools that are of general utility across various applications. And, we describe a new approach based on a Web services interface that allows a client to access the data in a user-friendly fashion while allowing maximum flexibility to execute desired analysis tasks. Sample applications will be discussed. This work is performed by the interdisciplinary ITR group, consisting of the author and Yi Li(1), Eric Perlman(2), Minping Wan(1

  19. The Constitutive Content of the Crime of Refusal or Evasion from Collecting Biological Samples According to the New Criminal Code

    Directory of Open Access Journals (Sweden)

    Minodora-Ioana BALAN-RUSU

    2014-03-01

    Full Text Available The purpose and the objectives of the research consist of examining the constitutive content of the crime of refusal or evasion from collecting biological samples according to the New Criminal Code, thus presenting some recent examples of judicial practice that may be applied in terms of new regulations imposed by the entry into force of the New Romanian Criminal Code. The research results consist of examining the constitutive content referring to judicial practice, and highlighting the elements of distinction between the two regulations. The study can be useful for both theorists and practitioners of criminal law, and to any physical entity.

  20. Spectrophotometric determination of copper(II) in pharmaceutical, biological and water samples by 4-(2'-benzothiazolylazo)-salicylic acid

    Science.gov (United States)

    Hashem, E. Y.; Seleim, M. M.; El-Zohry, A. M.

    2011-09-01

    A highly sensitive method is proposed to determine copper(II) ions by forming a stable complex through their interaction with 4-(2'-benzothiazolylazo)-salicylic acid (BTAS) at room temperature and pH of about 5.0. The complex gave a maximum absorption at λ = 485 nm with a molar absorptivity coefficient of 2.35·104 l/(mol·cm). The linear range for the copper determination is 0.63-5.04 mg/l. The method can be applied to determine copper ions in different biological specimens like some drugs and water samples.

  1. Advancements in mass spectrometry for biological samples: Protein chemical cross-linking and metabolite analysis of plant tissues

    Energy Technology Data Exchange (ETDEWEB)

    Klein, Adam [Iowa State Univ., Ames, IA (United States)

    2015-01-01

    This thesis presents work on advancements and applications of methodology for the analysis of biological samples using mass spectrometry. Included in this work are improvements to chemical cross-linking mass spectrometry (CXMS) for the study of protein structures and mass spectrometry imaging and quantitative analysis to study plant metabolites. Applications include using matrix-assisted laser desorption/ionization-mass spectrometry imaging (MALDI-MSI) to further explore metabolic heterogeneity in plant tissues and chemical interactions at the interface between plants and pests. Additional work was focused on developing liquid chromatography-mass spectrometry (LC-MS) methods to investigate metabolites associated with plant-pest interactions.

  2. Enhanced methods for unbiased deep sequencing of Lassa and Ebola RNA viruses from clinical and biological samples.

    Science.gov (United States)

    Matranga, Christian B; Andersen, Kristian G; Winnicki, Sarah; Busby, Michele; Gladden, Adrianne D; Tewhey, Ryan; Stremlau, Matthew; Berlin, Aaron; Gire, Stephen K; England, Eleina; Moses, Lina M; Mikkelsen, Tarjei S; Odia, Ikponmwonsa; Ehiane, Philomena E; Folarin, Onikepe; Goba, Augustine; Kahn, S Humarr; Grant, Donald S; Honko, Anna; Hensley, Lisa; Happi, Christian; Garry, Robert F; Malboeuf, Christine M; Birren, Bruce W; Gnirke, Andreas; Levin, Joshua Z; Sabeti, Pardis C

    2014-01-01

    We have developed a robust RNA sequencing method for generating complete de novo assemblies with intra-host variant calls of Lassa and Ebola virus genomes in clinical and biological samples. Our method uses targeted RNase H-based digestion to remove contaminating poly(rA) carrier and ribosomal RNA. This depletion step improves both the quality of data and quantity of informative reads in unbiased total RNA sequencing libraries. We have also developed a hybrid-selection protocol to further enrich the viral content of sequencing libraries. These protocols have enabled rapid deep sequencing of both Lassa and Ebola virus and are broadly applicable to other viral genomics studies.

  3. Formalin-induced fluorescence reveals cell shape and morphology in biological tissue samples.

    Directory of Open Access Journals (Sweden)

    Ulrich Leischner

    Full Text Available Ultramicroscopy is a powerful tool to reveal detailed three-dimensional structures of large microscopical objects. Using high magnification, we observed that formalin induces fluorescence more in extra-cellular space and stains cellular structures negatively, rendering cells as dark objects in front of a bright background. Here, we show this effect on a three-dimensional image stack of a hippocampus sample, focusing on the CA1 region. This method, called FIF-Ultramicroscopy, allows for the three-dimensional observation of cellular structures in various tissue types without complicated staining techniques.

  4. Phase microscopy of technical and biological samples through random phase modulation with a difuser

    DEFF Research Database (Denmark)

    Almoro, Percival; Pedrini, Giancarlo; Gundu, Phanindra Narayan

    2010-01-01

    A technique for phase microscopy using a phase diffuser and a reconstruction algorithm is proposed. A magnified specimen wavefront is projected on the diffuser plane that modulates the wavefront into a speckle field. The speckle patterns at axially displaced planes are sampled and used...... in an iterative phase retrieval algorithm based on a wave-propagation equation. The technique offers a whole-field and high-resolution wavefront reconstruction of unstained microstructures. Phase maps of photoresist targets and human cheek cells are obtained to demonstrate the effectiveness of our method. (C......) 2010 Optical Society of America...

  5. [Mercury determination in prehispanic Colombian biological samples: first experiences and investigation perspectives].

    Science.gov (United States)

    Idrovo, Alvaro J; Romero, William M; Silva, Elizabeth; Villamil de García, Gladys; Ortiz, Jaime E

    2002-03-01

    Mercury is useful as a tracer of environmental pollution levels. We measured mercury levels in hair from two human mummies (XII and XIV centuries, respectively) and from a stag (Odocoileus virginianus). The total and inorganic mercury levels found in the samples were very low. This findings indicated a minimal exposure to mercury in food and its absence in the atmosphere. Mercury levels can be used to explore the relationship between humans and environment, especially after metallurgy appeared, and to assess environmental contamination in different periods.

  6. Non-destructive evaluation of scientific and biological samples by scattering of 145 keV gamma rays

    Energy Technology Data Exchange (ETDEWEB)

    Singh, M.P.; Sharma, Amandeep; Singh, Bhajan [Physics Department, Punjabi University, Patiala, Punjab 147002 (India); Sandhu, B.S., E-mail: balvir@pbi.ac.i [Physics Department, Punjabi University, Patiala, Punjab 147002 (India)

    2010-09-15

    The objective of present experiment is to assign effective atomic number (Z{sub eff}) to samples of scientific interest (oxides of lanthanoids, also called rare earths, and alloys of lead and tin of known composition) and to measure stable iodine content of tissue (biological sample). An HPGe semiconductor detector, placed at 70{sup o} to the incident beam, detects gamma photons scattered from the sample under investigation. The experiment is performed on various elements with atomic number satisfying, 6 {<=}Z {<=} 82, for 145 keV incident photons. The intensity ratio of Rayleigh to Compton scattered peaks, corrected for photo-peak efficiency of gamma detector and absorption of photons in the sample and air, is plotted as a function of atomic number and constituted a fit curve. From this fit curve, the respective effective atomic numbers of the scientific samples are determined. The agreement of measured values of Z{sub eff} with theoretical calculations is found to be quite satisfactory. The measured intensity ratio from phantom (KI solutions, simulating thyroid content of stable iodine) varies linearly with KI concentration and provides stable iodine content of tissue.

  7. New Approach to Purging Monitoring Wells: Lower Flow Rates Reduce Required Purging Volumes and Sample Turbidity

    Science.gov (United States)

    It is generally accepted that monitoring wells must be purged to access formation water to obtain “representative” ground water quality samples. Historically anywhere from 3 to 5 well casing volumes have been removed prior to sample collection to evacuate the standing well water...

  8. Determination of amphetamines in biological samples using electro enhanced solid-phase microextraction-gas chromatography.

    Science.gov (United States)

    Zeng, Jingbin; Chen, Jingjing; Li, Min; Subhan, Fazle; Chong, Fayun; Wen, Chongying; Yu, Jianfeng; Cui, Bingwen; Chen, Xi

    2015-09-01

    In this work, an ordered mesoporous carbon (OMC)/Nafion coated fiber for solid-phase microextraction (SPME) was prepared and used as the working electrode for electro-enhanced SPME (EE-SPME) of amphetamines. The EE-SPME strategy is primarily based on the electro-migration and complementary charge interaction between fiber coating and ionic compounds. Compared with traditional SPME, EE-SPME exhibited excellent extraction efficiency for amphetamine (AP) and methamphetamine (MA) with an enhancement factor of 7.8 and 12.1, respectively. The present strategy exhibited good linearity for the determination of AP and MA in urine samples in the range of 10-1000ngmL(-1) and 20-1000ngmL(-1), respectively. The detection limits were found to be 1.2ngmL(-1) for AP and 4.8ngmL(-1) for MA. The relative standard deviations were calculated to be 6.2% and 8.5% for AP and MA, respectively. Moreover, the practical application of the proposed method was demonstrated by analyzing the amphetamines in urine and serum samples with satisfactory results.

  9. 3-Dimensional quantitative detection of nanoparticle content in biological tissue samples after local cancer treatment

    Energy Technology Data Exchange (ETDEWEB)

    Rahn, Helene, E-mail: helene.rahn@gmail.com [Institute of Fluid Mechanics, Chair of Magnetofluiddynamics, Technische Universitaet Dresden, Dresden 01069 (Germany); Alexiou, Christoph [ENT-Department, Section for Experimental Oncology and Nanomedicine (Else Kröner-Fresenius-Stiftungsprofessur), University Hospital Erlangen, Waldstraße 1, Erlangen 91054 (Germany); Trahms, Lutz [Physikalisch-Technische Bundesanstalt, Abbestraße 2-12, Berlin 10587 (Germany); Odenbach, Stefan [Institute of Fluid Mechanics, Chair of Magnetofluiddynamics, Technische Universitaet Dresden, Dresden 01069 (Germany)

    2014-06-01

    X-ray computed tomography is nowadays used for a wide range of applications in medicine, science and technology. X-ray microcomputed tomography (XµCT) follows the same principles used for conventional medical CT scanners, but improves the spatial resolution to a few micrometers. We present an example of an application of X-ray microtomography, a study of 3-dimensional biodistribution, as along with the quantification of nanoparticle content in tumoral tissue after minimally invasive cancer therapy. One of these minimal invasive cancer treatments is magnetic drug targeting, where the magnetic nanoparticles are used as controllable drug carriers. The quantification is based on a calibration of the XµCT-equipment. The developed calibration procedure of the X-ray-µCT-equipment is based on a phantom system which allows the discrimination between the various gray values of the data set. These phantoms consist of a biological tissue substitute and magnetic nanoparticles. The phantoms have been studied with XµCT and have been examined magnetically. The obtained gray values and nanoparticle concentration lead to a calibration curve. This curve can be applied to tomographic data sets. Accordingly, this calibration enables a voxel-wise assignment of gray values in the digital tomographic data set to nanoparticle content. Thus, the calibration procedure enables a 3-dimensional study of nanoparticle distribution as well as concentration. - Highlights: • Local cancer treatments are promising in reducing negative side effects occurring during conventional chemotherapy. • The nanoparticles play an important role in delivering drugs to the designated area during local cancer treatments as magnetic drug targeting. • We study the nanoparticles distribution in tumor tissue after magnetic drug targeting with X-ray computed tomography. • We achieved a 3-dimensional quantification of the nanoparticles content in tumor tissue out of digital tomographic data.

  10. High-resolution, high-transmission soft x-ray spectrometer for the study of biological samples

    Energy Technology Data Exchange (ETDEWEB)

    Fuchs, Oliver; Weinhardt, L.; Blum, M.; Welgand, M.; Umbach, E.; Bar, M.; Heske, C.; Denlinger, J.; Chuang, Y.-D.; McKinney, W.; Hussain, Z.; Gullikson, E.; Jones, M.; Batson, P.; Nelles, B.; Follath, R.

    2009-06-11

    We present a variable line-space grating spectrometer for soft s-rays that coverst the photon energy range between 130 and 650 eV. The optical design is based on the Hettrick-Underwood principle and tailored to synchrotron-based studies of radiation-sensitive biological samples. The spectrometer is able to record the entire spectral range in one shot, i.e., without any mechanical motion, at a resolving power of 1200 or better. Despite is slitless design, such a resolving power can be achieved for a source spot as large as (30 x 3000) micrometers squared, which is important for keeping beam damage effects in radiation-sensitive samples low. The high spectrometer efficiency allows recording of comprehensive two-dimensional resonant inelastic soft x-ray scatters (RIXS) maps with good statistics within several minutes. This is exemplarily demonstrated for a RIXS map of highly oriented pyrolytic graphite, which was taken with 10 min.

  11. High-resolution, high-transmission soft x-ray spectrometer for the study of biological samples

    Energy Technology Data Exchange (ETDEWEB)

    Fuchs, Oliver; Weinhardt, L.; Blum, M.; Weigand, M.; Umbach, E.; Bar, M.; Heske, Clemens; Denlinger, Jonathan; Chuang, Y.-D.; McKinney, Wayne; Hussain, Zahid; Gullikson, Eric; Jones, M.; Batson, Phil; Nelles, B.; Follath, R.

    2009-03-09

    We present a variable line-space grating spectrometer for soft x-rays that covers the photon energy range between 130 and 650 eV. The optical design is based on the Hettrick-Underwood principle and tailored to synchrotron-based studies of radiation-sensitive biological samples. The spectrometer is able to record the entire spectral range in one shot, i.e., without any mechanical motion, at a resolving power of 1200 or better. Despite its slitless design, such a resolving power can be achieved for a source spot as large as 30x3000 mu m2, which is important for keeping beam damage effects in radiation-sensitive samples low. The high spectrometer efficiency allows recording of comprehensive two-dimensional resonant inelastic soft x-ray scattering (RIXS) maps with good statistics within several minutes. This is exemplarily demonstrated for a RIXS map of highly oriented pyrolytic graphite, which was taken within 10 min.

  12. A Modified Alderman-Grant Coil makes possible an efficient cross-coil probe for high field solid-state NMR of lossy biological samples

    Science.gov (United States)

    Grant, Christopher V.; Yang, Yuan; Glibowicka, Mira; Wu, Chin H.; Park, Sang Ho; Deber, Charles M.; Opella, Stanley J.

    2009-11-01

    The design, construction, and performance of a cross-coil double-resonance probe for solid-state NMR experiments on lossy biological samples at high magnetic fields are described. The outer coil is a Modified Alderman-Grant Coil (MAGC) tuned to the 1H frequency. The inner coil consists of a multi-turn solenoid coil that produces a B 1 field orthogonal to that of the outer coil. This results in a compact nested cross-coil pair with the inner solenoid coil tuned to the low frequency detection channel. This design has several advantages over multiple-tuned solenoid coil probes, since RF heating from the 1H channel is substantially reduced, it can be tuned for samples with a wide range of dielectric constants, and the simplified circuit design and high inductance inner coil provides excellent sensitivity. The utility of this probe is demonstrated on two electrically lossy samples of membrane proteins in phospholipid bilayers (bicelles) that are particularly difficult for conventional NMR probes. The 72-residue polypeptide embedding the transmembrane helices 3 and 4 of the Cystic Fibrosis Transmembrane Conductance Regulator (CFTR) (residues 194-241) requires a high salt concentration in order to be successfully reconstituted in phospholipid bicelles. A second application is to paramagnetic relaxation enhancement applied to the membrane-bound form of Pf1 coat protein in phospholipid bicelles where the resistance to sample heating enables high duty cycle solid-state NMR experiments to be performed.

  13. Determination of glutathione and glutathione disulfide in biological samples: an in-depth review.

    Science.gov (United States)

    Monostori, Péter; Wittmann, Gyula; Karg, Eszter; Túri, Sándor

    2009-10-15

    Glutathione (GSH) is a thiol-containing tripeptide, which plays central roles in the defence against oxidative damage and in signaling pathways. Upon oxidation, GSH is transformed to glutathione disulfide (GSSG). The concentrations of GSH and GSSG and their molar ratio are indicators of cell functionality and oxidative stress. Assessment of redox homeostasis in various clinical states and medical applications for restoration of the glutathione status are of growing importance. This review is intended to provide a state-of-the-art overview of issues relating to sample pretreatment and choices for the separation and detection of GSH and GSSG. High-performance liquid chromatography, capillary electrophoresis and gas chromatography (as techniques with a separation step) with photometric, fluorimetric, electrochemical and mass spectrometric detection are discussed, stress being laid on novel approaches.

  14. Review of methods for determination of total protein and peptide concentration in biological samples.

    Science.gov (United States)

    Sapan, Christine V; Lundblad, Roger L

    2015-04-01

    Clinical proteomics can be defined as the use of proteomic technologies to identify and measure biomarkers in fluids and tissues. The current work is intended to review various methods used for the determination of the total concentration of protein or peptide in fluids and tissues and the application of such methods to clinical proteomics. Specifically, this article considers the approaches to the measurement of total protein concentration, not the measurement of the concentration of a specific protein or group of proteins in a larger mixture of proteins. The necessity of understanding various concepts such as fit-for-use, quality-by-design, and other regulatory elements is discussed, as is the significance of using suitable standards for the protein quality of various samples.

  15. Optimized IMAC-IMAC protocol for phosphopeptide recovery from complex biological samples

    DEFF Research Database (Denmark)

    Ye, Juanying; Zhang, Xumin; Young, Clifford;

    2010-01-01

    that the ionization efficiencies of the phosphoryl group and carboxylic group changed differently when the acetonitrile concentration was increased. A magnified difference was achieved in high acetonitrile content solutions. On the basis of this concept, an optimized phosphopeptide enrichment protocol was established...... using Fe(III)-NTA IMAC resin and it proved to be highly selective in the phosphopeptide enrichment of a highly diluted standard sample (1:1000) prior to MALDI MS analysis. We also observed that a higher iron purity led to an increased IMAC enrichment efficiency. The optimized method was then adapted...... peptides from singly phosphorylated peptides with successive IMAC enrichments. The rational improvements to the IMAC protocol described in this study provide more insights into the factors that affect IMAC performance for phosphopeptide recovery. The improved IMAC-IMAC method should allow more detailed...

  16. Kinetic spectrophotometric method for the determination of morphine in biological samples

    Science.gov (United States)

    Sheibani, A.; Shishehbore, M. Reza; Mirparizi, E.

    2010-10-01

    In this paper a simple, selective and inexpensive kinetic method was developed for the determination of morphine based on its inhibitory effect on the Janus green-bromate system in sulfuric acid media. The reaction was monitored spectrophotometrically at 618 nm by a fixed time method. The effect of different parameters such as concentration of reactants and temperature on the rate of reaction was investigated and optimum conditions were obtained. The calibration curve was linear in the concentration range 0.07-7.98 mg L -1 of morphine, and detection limit of the method was 3.0 × 10 -2 mg L -1. The relative standard deviation for five determinations of 3.74 mg L -1 of morphine was 0.57%. Finally, the proposed method was successfully applied to the determination of morphine in human urine and serum as real samples.

  17. A bench-top K X-ray fluorescence system for quantitative measurement of gold nanoparticles for biological sample diagnostics

    Energy Technology Data Exchange (ETDEWEB)

    Ricketts, K., E-mail: k.ricketts@ucl.ac.uk [Division of Surgery and Interventional Sciences, University College London, Royal Free Campus, Rowland Hill Street, London NW3 2PF (United Kingdom); Guazzoni, C.; Castoldi, A. [Dipartimento di Elettronica, Informazione e Bioingegneria Politecnico di Milano and INFN, Sezione di Milano P.za Leonardo da Vinci, 32-20133 Milano (Italy); Royle, G. [Department of Medical Physics and Bioengineering, University College London, Malet Place Engineering Building, Gower Street, London WC1E 6BT (United Kingdom)

    2016-04-21

    Gold nanoparticles can be targeted to biomarkers to give functional information on a range of tumour characteristics. X-ray fluorescence (XRF) techniques offer potential quantitative measurement of the distribution of such heavy metal nanoparticles. Biologists are developing 3D tissue engineered cellular models on the centimetre scale to optimise targeting techniques of nanoparticles to a range of tumour characteristics. Here we present a high energy bench-top K-X-ray fluorescence system designed for sensitivity to bulk measurement of gold nanoparticle concentration for intended use in such thick biological samples. Previous work has demonstrated use of a L-XRF system in measuring gold concentrations but being a low energy technique it is restricted to thin samples or superficial tumours. The presented system comprised a high purity germanium detector and filtered tungsten X-ray source, capable of quantitative measurement of gold nanoparticle concentration of thicker samples. The developed system achieved a measured detection limit of between 0.2 and 0.6 mgAu/ml, meeting specifications of biologists and being approximately one order of magnitude better than the detection limit of alternative K-XRF nanoparticle detection techniques. The scatter-corrected K-XRF signal of gold was linear with GNP concentrations down to the detection limit, thus demonstrating potential in GNP concentration quantification. The K-XRF system demonstrated between 5 and 9 times less sensitivity than a previous L-XRF bench-top system, due to a fundamental limitation of lower photoelectric interaction probabilities at higher K-edge energies. Importantly, the K-XRF technique is however less affected by overlying thickness, and so offers future potential in interrogating thick biological samples.

  18. Polybrominated diphenyl ethers in water, sediment, soil, and biological samples from different industrial areas in Zhejiang, China

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Junxia; Lin, Zhenkun [Zhejiang Provincial Key Lab for Technology and Application of Model Organisms, Institute of Watershed Science and Environmental Ecology, Wenzhou Medical College, Wenzhou 325035 (China); Lin, Kuangfei [School of Resources and Environmental Engineering, East China University of Science and Technology/State Environmental Protection Key Laboratory of Environmental Risk Assessment and Control on Chemical Process, Shanghai 200237 (China); Wang, Chunyan [Zhejiang Provincial Key Lab for Technology and Application of Model Organisms, Institute of Watershed Science and Environmental Ecology, Wenzhou Medical College, Wenzhou 325035 (China); Zhang, Wei [School of Resources and Environmental Engineering, East China University of Science and Technology/State Environmental Protection Key Laboratory of Environmental Risk Assessment and Control on Chemical Process, Shanghai 200237 (China); Cui, Changyuan [Zhejiang Provincial Key Lab for Technology and Application of Model Organisms, Institute of Watershed Science and Environmental Ecology, Wenzhou Medical College, Wenzhou 325035 (China); Lin, Junda [Department of Biological Sciences, Florida Institute of Technology, Melbourne, FL 32901 (United States); Dong, Qiaoxiang, E-mail: dqxdong@163.com [Zhejiang Provincial Key Lab for Technology and Application of Model Organisms, Institute of Watershed Science and Environmental Ecology, Wenzhou Medical College, Wenzhou 325035 (China); Huang, Changjiang, E-mail: cjhuang5711@163.com [Zhejiang Provincial Key Lab for Technology and Application of Model Organisms, Institute of Watershed Science and Environmental Ecology, Wenzhou Medical College, Wenzhou 325035 (China)

    2011-12-15

    Highlights: Black-Right-Pointing-Pointer We examined PBDE concentrations in various matrices from different industrial areas. Black-Right-Pointing-Pointer Elevated PBDE levels were found in areas with low-voltage electrical manufactures. Black-Right-Pointing-Pointer Areas with e-waste recycling activities also had higher PBDE concentrations. Black-Right-Pointing-Pointer PBDE content and composition in water samples varied from one area to another. Black-Right-Pointing-Pointer PBDE composition in sediment/soil and biological samples was predominated by BDE-209. - Abstract: Polybrominated diphenyl ethers (PBDEs) have been used extensively in electrical and electronic products, but little is known about their distribution in the environment surrounding the manufacturing factories. This study reports PBDE contamination in various matrices from the location (Liushi, Zhejiang province) that produces more than 70% of the low-voltage electrical appliances in China. Additionally, PBDE contamination was compared with other industries such as the e-waste recycling business (Fengjiang) in the same region. Specifically, we measured seven PBDE congeners (BDEs - 47, 99, 100, 153, 154, 183, and 209) in water, sediment, soil, plant, and animal tissues from four different areas in this region. The present study revealed elevated PBDE concentrations in all matrices collected from Liushi and Fengjiang in comparison with highly industrialized areas without significant PBDE contamination sources. In water samples, there were large variations of PBDE content and composition across different areas. In sediment/soil and biological samples, BDE-209 was the predominant congener and this could be due to the abundant usage of deca-BDE mixtures in China. Our findings provide the very first data on PBDE contamination in the local environments surrounding the electronics industry, and also reveal widespread PBDE contamination in highly industrialized coastal regions of China.

  19. Integrating silicon nanowire field effect transistor, microfluidics and air sampling techniques for real-time monitoring biological aerosols.

    Science.gov (United States)

    Shen, Fangxia; Tan, Miaomiao; Wang, Zhenxing; Yao, Maosheng; Xu, Zhenqiang; Wu, Yan; Wang, Jindong; Guo, Xuefeng; Zhu, Tong

    2011-09-01

    Numerous threats from biological aerosol exposures, such as those from H1N1 influenza, SARS, bird flu, and bioterrorism activities necessitate the development of a real-time bioaerosol sensing system, which however is a long-standing challenge in the field. Here, we developed a real-time monitoring system for airborne influenza H3N2 viruses by integrating electronically addressable silicon nanowire (SiNW) sensor devices, microfluidics and bioaerosol-to-hydrosol air sampling techniques. When airborne influenza H3N2 virus samples were collected and delivered to antibody-modified SiNW devices, discrete nanowire conductance changes were observed within seconds. In contrast, the conductance levels remained relatively unchanged when indoor air or clean air samples were delivered. A 10-fold increase in virus concentration was found to give rise to about 20-30% increase in the sensor response. The selectivity of the sensing device was successfully demonstrated using H1N1 viruses and house dust allergens. From the simulated aerosol release to the detection, we observed a time scale of 1-2 min. Quantitative polymerase chain reaction (qPCR) tests revealed that higher virus concentrations in the air samples generally corresponded to higher conductance levels in the SiNW devices. In addition, the display of detection data on remote platforms such as cell phone and computer was also successfully demonstrated with a wireless module. The work here is expected to lead to innovative methods for biological aerosol monitoring, and further improvements in each of the integrated elements could extend the system to real world applications.

  20. Amino Nitrogen Quantum Dots-Based Nanoprobe for Fluorescence Detection and Imaging of Cysteine in Biological Samples.

    Science.gov (United States)

    Tang, Zhijiao; Lin, Zhenhua; Li, Gongke; Hu, Yuling

    2017-03-20

    Fluorescent amino nitrogen quantum dots (aN-dots) were synthesized by microwave-assisted method using 2-azidoimidazole and aqueous ammonia. The aN-dots have a nitrogen component up to 40%, which exhibit high fluorescence quantum yield, good photostability, and excellent biocompatibility. We further explored the use of the aN-dots combined with AuNPs as a nanoprobe for detecting fluorescently and imaging of cysteine (Cys) in complex biological samples. In this sensing system, the fluorescence of aN-dots was quenched significantly by gold nanoparticles (AuNPs), while the addition of Cys can lead to the fluorescence signal recovery. Furthermore, we have demonstrated that this strategy can offer a rapid and selective detection of Cys with a good linear relationship in the range of 0.3-3.0 μmol/L. As expected, this assay was successfully applied to the detection of Cys in human serum and plasma samples with recoveries ranging from 90.0% to 106.7%. Especially, the nanoprobe exhibits good cell membrane permeability and excellent biocompatibility by CCK-8 assay, which is favorable for bioimaging applications. Therefore, this fluorescent probe ensemble was further used for imaging of Cys in living cells, which suggests our proposed method has strong potential for clinical diagnosis. As a novel member of the quantum-dot family, the aN-dots hold great promise to broaden applications in biological systems.

  1. Cloud-point extraction, preconcentration and spectrophotometric determination of trace quantities of copper in food, water and biological samples.

    Science.gov (United States)

    Gouda, Ayman A; Amin, Alaa S

    2014-01-01

    A new, simple and sensitive cloud point extraction procedure was presented for the preconcentration and determination of copper(II) ion in food, water and biological samples. The analyte was complexed with a new synthesized reagent, 2-amino-4-(m-tolylazo)pyridine-3-ol (ATAP) as a new complexing agent and Triton X-114 as the surfactant. After centrifugation, dilution of the surfactant-rich phase with 0.4 mL of ethanol acidified with 1.0M HNO3 was performed after phase separation, and the copper contents were measured by spectrophotometry at λmax 608 nm. The influence of analytical parameters including concentration of complexing agent, Triton X-114, pH, equilibration temperature and time, centrifuge rate and time were optimized. The analytical characteristics of the method (e.g. linear range, molar absorptivity, Sandell sensitivity, optimum Ringbom concentration ranges limits of detection and quantification, preconcentration factor, and improvement factors) were obtained. Linearity was obeyed in the range of 4.0-115 ng mL(-1) of Cu(II) ion. The detection and quantification limits of the method were 1.20 and 3.94 ng mL(-1) of Cu(II) ion, respectively. The interference effect of some anions and cations was also tested. The method was applied for determination of copper in food, water and biological samples.

  2. Use of cloud-point preconcentration for spectrophotometric determination of trace amounts of antimony in biological and environmental samples.

    Science.gov (United States)

    El-Sharjawy, Abdel-Azeem M; Amin, Alaa S

    2016-01-01

    This work presents a cloud-point extraction process using the micelle-mediated extraction method for simultaneous preconcentration and determination of Sb(III) and Sb(V) species in biological and environmental samples as a prior preconcentration step to their spectrophotometric determination. The analytical system is based on the selective reaction between Sb(III) and 3-dichloro-6-(3-carboxy-2-hydroxy-1-naphthylazo)quinoxaline (DCHNAQ) in the presence of cetyltrimethylammonium bromide (CTAB) and potassium iodide at pH 4.5. Total Sb concentration was determined after reduction of Sb(V) to Sb(III) in the presence of potassium iodide and ascorbic acid. The optimal reaction conditions and extraction were studied, and the analytical characteristics of the method (e.g., limits of detection and quantification, linear range, preconcentration, improvement factors) were obtained. Linearity for Sb(III) was obeyed in the range of 0.2-20 ng ml(-1). The detection and quantification limits for the determination of Sb(III) were 0.055 and 0.185 ng ml(-1), respectively. The method has a lower detection limit and wider linear range, inexpensive instrument, and low cost, and is more sensitive compared with most other methods. The interference effect of some anions and cations was also studied. The method was applied to the determination of Sb(III) in the presence of Sb(V) and total antimony in blood plasma, urine, biological, and water samples.

  3. Development of a mild mercaptoethanol extraction method for determination of mercury species in biological samples by HPLC-ICP-MS.

    Science.gov (United States)

    Wang, Meng; Feng, Weiyue; Shi, Junwen; Zhang, Fang; Wang, Bing; Zhu, Motao; Li, Bai; Zhao, Yuliang; Chai, Zhifang

    2007-03-30

    A mild, efficient and convenient extraction method of using 2-mercaptoethanol contained extractant solution combined with an incubator shaker for determination of mercury species in biological samples by HPLC-ICP-MS has been developed. The effects of the concentration of 2-mercaptoethanol, the composition of the extractant solution and the shaking time on the efficiency of mercury extraction were evaluated. The optimization experiments indicated that the quantitative extraction of mercury species from biological samples could be achieved by using 0.1% (v/v) HCl, 0.1% (v/v) 2-mercapoethanol and 0.15% (m/v) KCl extractant solution in an incubator shaker for shaking overnight (about 12h) at room temperature. The established method was validated by analysis of various biological certified reference materials, including NRCC DOLT-3 (dogfish liver), IAEA 436 (tuna fish), IAEA MA-B-3/TM (garfish filet), IAEA MA-M-2/TM (mussel tissue), GBW 08193 (bovine liver) and GBW 08572 (prawn). The analytical results of the reference materials were in good agreement with the certified or reference values of both methyl and total mercury, indicating that no distinguishable transformation between mercury species had occurred during the extraction and determination procedures. The limit of detection (LOD) for methyl (CH(3)Hg(+)) and inorganic mercury (Hg(2+)) by the method are both as 0.2microg L(-1). The relative standard deviation (R.S.D.s) for CH(3)Hg(+) and Hg(2+) are 3.0% and 5.8%, respectively. The advantages of the developed extraction method are that (1) it is easy to operate in HPLC-ICP-MS for mercury species determination since the extracted solution can be directly injected into the HPLC column without pH adjustment and (2) the memory effect of mercury in the ICP-MS measurement system can be reduced.

  4. Radioreceptor assay for analysis of fentanyl and its analogs in biological samples

    Energy Technology Data Exchange (ETDEWEB)

    Alburges, M.E.

    1988-01-01

    The assay is based on the competition of these drugs with ({sup 3}H) fentanyl for opioid receptors in membrane preparations of rat forebrain in vitro. The binding in stereospecific, reversible and saturable. Scatchard plots of saturation suggest the presence of high and low affinity binding sites. Morphine and hydromorphone complete with ({sup 3}H)fentanyl for the opioid receptor, but other morphine-like compounds were relatively weak displacers of ({sup 3}H)fentanyl. Many other commonly abused drugs do not compete with ({sup 3}H)fentanyl for the opioid receptors. Urine samples from animals injected with fentanyl, ({plus minus})-cis-3-methylfentanyl, alpha-methylfentanyl, butyrylfentanyl and benzylfentanyl were analyzed by radioreceptor assay, radioimmunoassay, and gas chromatography/mass spectrometry. Urinary analysis of fentanyl showed a good correlation with these three methods; however, discrepancies were observed in the analysis of fentanyl analogs. This radioreceptor assay is well-suited as an initial assay for the detection of active analogs of fentanyl in urine with good correlation with other techniques in the analysis of fentanyl; however, there is substantial disagreement between techniques in the quantitation of fentanyl analogs. The implications of these discrepancies are discussed.

  5. SILAC-Based Quantitative Strategies for Accurate Histone Posttranslational Modification Profiling Across Multiple Biological Samples.

    Science.gov (United States)

    Cuomo, Alessandro; Soldi, Monica; Bonaldi, Tiziana

    2017-01-01

    Histone posttranslational modifications (hPTMs) play a key role in regulating chromatin dynamics and fine-tuning DNA-based processes. Mass spectrometry (MS) has emerged as a versatile technology for the analysis of histones, contributing to the dissection of hPTMs, with special strength in the identification of novel marks and in the assessment of modification cross talks. Stable isotope labeling by amino acid in cell culture (SILAC), when adapted to histones, permits the accurate quantification of PTM changes among distinct functional states; however, its application has been mainly confined to actively dividing cell lines. A spike-in strategy based on SILAC can be used to overcome this limitation and profile hPTMs across multiple samples. We describe here the adaptation of SILAC to the analysis of histones, in both standard and spike-in setups. We also illustrate its coupling to an implemented "shotgun" workflow, by which heavy arginine-labeled histone peptides, produced upon Arg-C digestion, are qualitatively and quantitatively analyzed in an LC-MS/MS system that combines ultrahigh-pressure liquid chromatography (UHPLC) with new-generation Orbitrap high-resolution instrument.

  6. Rapid determination of amino acids in biological samples using a monolithic silica column.

    Science.gov (United States)

    Song, Yanting; Funatsu, Takashi; Tsunoda, Makoto

    2012-05-01

    A high-performance liquid chromatography method in which fluorescence detection is used for the simultaneous determination of 21 amino acids is proposed. Amino acids were derivatized with 4-fluoro-7-nitro-2,1,3-benzoxadiazole (NBD-F) and then separated on a monolithic silica column (MonoClad C18-HS, 150 mm×3 mm i.d.). A mixture of 25 mM citrate buffer containing 25 mM sodium perchlorate (pH 5.5) and acetonitrile was used as the mobile phase. We found that the most significant factor in the separation was temperature, and a linear temperature gradient from 30 to 49°C was used to control the column temperature. The limits of detection and quantification for all amino acids ranged from 3.2 to 57.2 fmol and 10.8 to 191 fmol, respectively. The calibration curves for the NBD-amino acid had good linearity within the range of 40 fmol to 40 pmol when 6-aminocaproic acid was used as an internal standard. Using only conventional instruments, the 21 amino acids could be analyzed within 10 min. This method was found to be suitable for the quantification of the contents of amino acids in mouse plasma and adrenal gland samples.

  7. Signal and Image Processing of Optical Coherence Tomography at 1310 nm Wavelength for Non Biological Samples

    Directory of Open Access Journals (Sweden)

    Yogesh Rao

    2015-04-01

    Full Text Available OCT is a recently developed optical interferometric technique for non-invasive diagnostic medical imaging in vivo; the most sensitive optical imaging modality.OCT finds its application in ophthalmology, blood flow estimation and cancer diagnosis along with many non biomedical applications. The main advantage of OCT is its high resolution which is in µm range and depth of penetration in mm range. Unlike other techniques like X rays and CT scan, OCT does not comprise any x ray source and therefore no radiations are involved. This research work discusses the basics of spectral domain OCT (SD-OCT, experimental setup, data acquisition and signal processing involved in OCT systems. Simulation of OCT involving modelling and signal processing, carried out on Lab VIEW platform has been discussed. Using the experimental setup, some of the non biomedical samples have been scanned. The signal processing and image processing of the scanned data was carried out in MATLAB and Lab VIEW, some of the results thus obtained have been discussed in the end.

  8. Evaluation of cadmium, chromium, nickel, and zinc in biological samples of psoriasis patients living in Pakistani cement factory area.

    Science.gov (United States)

    Afridi, Hassan Imran; Kazi, Tasneem Gul; Kazi, Naveed; Kandhro, Ghulam Abbas; Baig, Jameel Ahmed; Shah, Abdul Qadir; Khan, Sumaira; Kolachi, Nida Fatima; Wadhwa, Sham Kumar; Shah, Faheem; Jamali, Mohammad Khan; Arain, Mohammad Balal

    2011-09-01

    Psoriasis is a noncontiguous common and chronic skin disorder. The aim of the present study was to compare the level of trace elements cadmium (Cd), chromium (Cr), Nickel (Ni), and zinc (Zn) in biological samples (whole blood, urine, and scalp hair) of psoriasis patients of both gender age ranged (25-55 years) at mild, moderate severe, and more severe stage (n = 418) living in the vicinity of cement factory. For comparison purposes, healthy age-matched referent subjects, residents of industrial and non-industrial area, of both gender were also selected (n = 241). The concentrations of trace and toxic elements were measured by atomic absorption spectrophotometer prior to microwave-assisted acid digestion. The validity and accuracy of methodology was checked by using certified reference materials (CRMs) and conventional wet acid digestion method on same CRMs and real samples. The results of this study showed that the mean values of Cd, Cr, Ni, and Pb were significantly higher in scalp hair, blood, and urine samples of mild and severe psoriasis patients as compared to referents (p < 0.001), while the concentration of Zn was lower in the scalp hair and blood, but higher in the urine samples of psoriasis patients. The deficiency of Zn in psoriasis patients may be undoubtedly caused by the toxic element exposures via cement factory.

  9. Application of picosecond laser-induced breakdown spectroscopy to quantitative analysis of boron in meatballs and other biological samples.

    Science.gov (United States)

    Hedwig, Rinda; Lahna, Kurnia; Lie, Zener Sukra; Pardede, Marincan; Kurniawan, Koo Hendrik; Tjia, May On; Kagawa, Kiichiro

    2016-11-10

    This report presents the results of laser-induced breakdown spectroscopy (LIBS) study on biological and food samples of high water content using a picosecond (ps) laser at low output energy of 10 mJ and low-pressure helium ambient gas at 2 kPa. Evidence of excellent emission spectra of various analyte elements with very low background is demonstrated for a variety of samples without the need of sample pretreatment. Specifically, limits of detection in the range of sub-ppm are obtained for hazardous Pb and B impurities in carrots and meatballs. This study also shows the inferior performance of LIBS using a nanosecond laser and atmospheric ambient air for a soft sample of high water content and thereby explains its less successful applications in previous attempts. The present result has instead demonstrated the feasibility and favorable results of employing LIBS with a ps laser and low-pressure helium ambient gas as a less costly and more practical alternative to inductively coupled plasma for regular high sensitive inspection of harmful food preservatives and environmental pollutants.

  10. On-line Determination of Zinc in Water and Biological Samples after Its Preconcentration onto Zincon Anchored Polyurethane Foam.

    Science.gov (United States)

    Azeem, Sami M Abdel; Hanafi, Hassan A; El-Shahat, M F

    2015-01-01

    A fast and sensitive on-line procedure for the determination of zinc in water and biological samples was developed. Zinc was preconcentrated in a mini-column packed with polyurethane foam (PUF) chemically modified with zincon via -N=N- bonding. The optimal conditions for preconcentration were pH 8.5 and sample flow rate of 4.0 mL min(-1). Quantitative desorption of Zn(II) was obtained by 0.1 mol L(-1) hydrochloric acid and subsequent spectrophotmetric determination using 4-(2-pyridylazo)-resorcinol at 498 nm. The obtained detection limit was found to be 3.0 ng mL(-1), precision (RSD) was 4.8 and 6.7% at 20 and 110 ng mL(-1), respectively, for 60 s preconcentration time and enrichment factor was 31. The linearity range was from 10 to 120 ng mL(-1) and maximum sample throughput was 20 h(-1). Finally, the method was successfully applied to the determination of zinc in tap water, Nile River water and human urine samples with RSD in the range of 1.1 - 8.3%.

  11. Probabilistic Requirements (Partial) Verification Methods Best Practices Improvement. Variables Acceptance Sampling Calculators: Derivations and Verification of Plans. Volume 1

    Science.gov (United States)

    Johnson, Kenneth L.; White, K, Preston, Jr.

    2012-01-01

    The NASA Engineering and Safety Center was requested to improve on the Best Practices document produced for the NESC assessment, Verification of Probabilistic Requirements for the Constellation Program, by giving a recommended procedure for using acceptance sampling by variables techniques. This recommended procedure would be used as an alternative to the potentially resource-intensive acceptance sampling by attributes method given in the document. This document contains the outcome of the assessment.

  12. Critical evaluation of the JDO API for the persistence and portability requirements of complex biological databases

    Directory of Open Access Journals (Sweden)

    Schwieger Michael

    2005-01-01

    Full Text Available Abstract Background Complex biological database systems have become key computational tools used daily by scientists and researchers. Many of these systems must be capable of executing on multiple different hardware and software configurations and are also often made available to users via the Internet. We have used the Java Data Object (JDO persistence technology to develop the database layer of such a system known as the SigPath information management system. SigPath is an example of a complex biological database that needs to store various types of information connected by many relationships. Results Using this system as an example, we perform a critical evaluation of current JDO technology; discuss the suitability of the JDO standard to achieve portability, scalability and performance. We show that JDO supports portability of the SigPath system from a relational database backend to an object database backend and achieves acceptable scalability. To answer the performance question, we have created the SigPath JDO application benchmark that we distribute under the Gnu General Public License. This benchmark can be used as an example of using JDO technology to create a complex biological database and makes it possible for vendors and users of the technology to evaluate the performance of other JDO implementations for similar applications. Conclusions The SigPath JDO benchmark and our discussion of JDO technology in the context of biological databases will be useful to bioinformaticians who design new complex biological databases and aim to create systems that can be ported easily to a variety of database backends.

  13. A step-by-step protocol for assaying protein carbonylation in biological samples.

    Science.gov (United States)

    Colombo, Graziano; Clerici, Marco; Garavaglia, Maria Elisa; Giustarini, Daniela; Rossi, Ranieri; Milzani, Aldo; Dalle-Donne, Isabella

    2016-04-15

    Protein carbonylation represents the most frequent and usually irreversible oxidative modification affecting proteins. This modification is chemically stable and this feature is particularly important for storage and detection of carbonylated proteins. Many biochemical and analytical methods have been developed during the last thirty years to assay protein carbonylation. The most successful method consists on protein carbonyl (PCO) derivatization with 2,4-dinitrophenylhydrazine (DNPH) and consequent spectrophotometric assay. This assay allows a global quantification of PCO content due to the ability of DNPH to react with carbonyl giving rise to an adduct able to absorb at 366 nm. Similar approaches were also developed employing chromatographic separation, in particular HPLC, and parallel detection of absorbing adducts. Subsequently, immunological techniques, such as Western immunoblot or ELISA, have been developed leading to an increase of sensitivity in protein carbonylation detection. Currently, they are widely employed to evaluate change in total protein carbonylation and eventually to highlight the specific proteins undergoing selective oxidation. In the last decade, many mass spectrometry (MS) approaches have been developed for the identification of the carbonylated proteins and the relative amino acid residues modified to carbonyl derivatives. Although these MS methods are much more focused and detailed due to their ability to identify the amino acid residues undergoing carbonylation, they still require too expensive equipments and, therefore, are limited in distribution. In this protocol paper, we summarise and comment on the most diffuse protocols that a standard laboratory can employ to assess protein carbonylation; in particular, we describe step-by-step the different protocols, adding suggestions coming from our on-bench experience.

  14. 76 FR 47211 - Report on the Performance of Drug and Biologics Firms in Conducting Postmarketing Requirements...

    Science.gov (United States)

    2011-08-04

    ..., clinical efficacy, clinical pharmacology, and nonclinical toxicology study/clinical trial either required... consolidation of certain therapeutic products formerly regulated by CBER into CDER. Consequently, CDER...

  15. Sample requirements and design of an inter-laboratory trial for radiocarbon laboratories

    NARCIS (Netherlands)

    Bryant, C; Carmi, [No Value; Cook, G; Gulliksen, S; Harkness, D; Heinemeier, J; McGee, E; Naysmith, P; Possnert, G; van der Plicht, H; van Strydonck, M; Carmi, Israel

    2000-01-01

    An on-going inter-comparison programme which is focused on assessing and establishing consensus protocols to be applied in the identification, selection and sub-sampling of materials for subsequent C-14 analysis is described. The outcome of the programme will provide a detailed quantification of the

  16. Is routine karyotyping required in prenatal samples with a molecular or metabolic referral?

    Directory of Open Access Journals (Sweden)

    Kooper Angelique JA

    2012-01-01

    Full Text Available Abstract As a routine, karyotyping of invasive prenatal samples is performed as an adjunct to referrals for DNA mutation detection and metabolic testing. We performed a retrospective study on 500 samples to assess the diagnostic value of this procedure. These samples included 454 (90.8% chorionic villus (CV and 46 (9.2% amniocenteses specimens. For CV samples karyotyping was based on analyses of both short-term culture (STC and long-term culture (LTC cells. Overall, 19 (3.8% abnormal karyotypes were denoted: four with a common aneuploidy (trisomy 21, 18 and 13, two with a sex chromosomal aneuploidy (Klinefelter syndrome, one with a sex chromosome mosaicism and twelve with various autosome mosaicisms. In four cases a second invasive test was performed because of an abnormal finding in the STC. Taken together, we conclude that STC and LTC karyotyping has resulted in a diagnostic yield of 19 (3.8% abnormal cases, including 12 cases (2.4% with an uncertain significance. From a diagnostic point of view, it is desirable to limit uncertain test results as secondary test findings. Therefore, we recommend a more targeted assay, such as e.g. QF-PCR, as a replacement of the STC and to provide parents the autonomy to choose between karyotyping and QF-PCR.

  17. Historical precedence and technical requirements of biological weapons use : a threat assessment.

    Energy Technology Data Exchange (ETDEWEB)

    Estes, Daniel P.; Vogel, Kathleen Margaret; Gaudioso, Jennifer Marie; Hickok, Lauren T.; Jung, Danielle F.; Barnett, Natalie Beth; Frerichs, Rebecca L.; Salerno, Reynolds Mathewson

    2004-05-01

    The threat from biological weapons is assessed through both a comparative historical analysis of the patterns of biological weapons use and an assessment of the technological hurdles to proliferation and use that must be overcome. The history of biological weapons is studied to learn how agents have been acquired and what types of states and substate actors have used agents. Substate actors have generally been more willing than states to use pathogens and toxins and they have focused on those agents that are more readily available. There has been an increasing trend of bioterrorism incidents over the past century, but states and substate actors have struggled with one or more of the necessary technological steps. These steps include acquisition of a suitable agent, production of an appropriate quantity and form, and effective deployment. The technological hurdles associated with the steps present a real barrier to producing a high consequence event. However, the ever increasing technological sophistication of society continually lowers the barriers, resulting in a low but increasing probability of a high consequence bioterrorism event.

  18. Gay and Bisexual Men's Perceptions of the Donation and Use of Human Biological Samples for Research: A Qualitative Study.

    Directory of Open Access Journals (Sweden)

    Chris Patterson

    Full Text Available Human biological samples (biosamples are increasingly important in diagnosing, treating and measuring the prevalence of illnesses. For the gay and bisexual population, biosample research is particularly important for measuring the prevalence of human immunodeficiency virus (HIV. By determining people's understandings of, and attitudes towards, the donation and use of biosamples, researchers can design studies to maximise acceptability and participation. In this study we examine gay and bisexual men's attitudes towards donating biosamples for HIV research. Semi-structured telephone interviews were conducted with 46 gay and bisexual men aged between 18 and 63 recruited in commercial gay scene venues in two Scottish cities. Interview transcripts were analysed thematically using the framework approach. Most men interviewed seemed to have given little prior consideration to the issues. Participants were largely supportive of donating tissue for medical research purposes, and often favourable towards samples being stored, reused and shared. Support was often conditional, with common concerns related to: informed consent; the protection of anonymity and confidentiality; the right to withdraw from research; and ownership of samples. Many participants were in favour of the storage and reuse of samples, but expressed concerns related to data security and potential misuse of samples, particularly by commercial organisations. The sensitivity of tissue collection varied between tissue types and collection contexts. Blood, urine, semen and bowel tissue were commonly identified as sensitive, and donating saliva and as unlikely to cause discomfort. To our knowledge, this is the first in-depth study of gay and bisexual men's attitudes towards donating biosamples for HIV research. While most men in this study were supportive of donating tissue for research, some clear areas of concern were identified. We suggest that these minority concerns should be accounted

  19. Investigational new drug safety reporting requirements for human drug and biological products and safety reporting requirements for bioavailability and bioequivalence studies in humans. Final rule.

    Science.gov (United States)

    2010-09-29

    The Food and Drug Administration (FDA) is amending its regulations governing safety reporting requirements for human drug and biological products subject to an investigational new drug application (IND). The final rule codifies the agency's expectations for timely review, evaluation, and submission of relevant and useful safety information and implements internationally harmonized definitions and reporting standards. The revisions will improve the utility of IND safety reports, reduce the number of reports that do not contribute in a meaningful way to the developing safety profile of the drug, expedite FDA's review of critical safety information, better protect human subjects enrolled in clinical trials, subject bioavailability and bioequivalence studies to safety reporting requirements, promote a consistent approach to safety reporting internationally, and enable the agency to better protect and promote public health.

  20. Rapid Isolation and Determination of Flavones in Biological Samples Using Zinc Complexation Coupled with High-Performance Liquid Chromatography

    Directory of Open Access Journals (Sweden)

    Chenghe Sun

    2016-08-01

    Full Text Available Chlorophyll-type contaminants are commonly encountered in the isolation and determination of flavones of plant aerial plant parts. Heme is also a difficult background substance in whole blood analysis. Both chlorophyll and heme are porphyrin type compounds. In this study, a rapid method for isolating flavones with 5-hydroxyl or ortho-hydroxyl groups from biological samples was developed based on the different solubilities of porphyrin-metal and flavone-metal complexes. It is important that other background substances, e.g., proteins and lipids, are also removed from flavones without an additional processing. The recoveries of scutellarin, baicalin, baicalein, wogonoside and wogonin, which are the primary constituents of Scutellaria baicalensis (skullcaps were 99.65% ± 1.02%, 98.98% ± 0.73%, 99.65% ± 0.03%, 97.59% ± 0.09% and 95.19% ± 0.47%, respectively. As a sample pretreatment procedure, this method was coupled to high-performance liquid chromatography (HPLC with good separation, sensitivity and linearity and was applied to determine the flavone content in different aerial parts of S. baicalensis and in dried blood spot samples.

  1. Sensitive Determination of Terazosin in Pharmaceutical Formulations and Biological Samples by Ionic-Liquid Microextraction Prior to Spectrofluorimetry

    Directory of Open Access Journals (Sweden)

    Mohsen Zeeb

    2012-01-01

    Full Text Available An efficient and environmentally friendly sample preparation method based on the application of hydrophobic 1-Hexylpyridinium hexafluorophosphate [Hpy][PF6] ionic liquid (IL as a microextraction solvent was proposed to preconcentrate terazosin. The performance of the microextraction method was improved by introducing a common ion of pyridinium IL into the sample solution. Due to the presence of the common ion, the solubility of IL significantly decreased. As a result, the phase separation successfully occurred even at high ionic strength, and the volume of the settled IL-phase was not influenced by variations in the ionic strength (up to 30% w/v. After preconcentration step, the enriched phase was introduced to the spectrofluorimeter for the determination of terazosin. The obtained results revealed that this system did not suffer from the limitations of that in conventional ionic-liquid microextraction. Under optimum experimental conditions, the proposed method provided a limit of detection (LOD of 0.027 μg L−1 and a relative standard deviation (R.S.D. of 2.4%. The present method was successfully applied to terazosin determination in actual pharmaceutical formulations and biological samples. Considering the large variety of ionic liquids, the proposed microextraction method earns many merits, and will present a wide application in the future.

  2. Sensitive determination of terazosin in pharmaceutical formulations and biological samples by ionic-liquid microextraction prior to spectrofluorimetry.

    Science.gov (United States)

    Zeeb, Mohsen; Sadeghi, Mahdi

    2012-01-01

    An efficient and environmentally friendly sample preparation method based on the application of hydrophobic 1-Hexylpyridinium hexafluorophosphate [Hpy][PF(6)] ionic liquid (IL) as a microextraction solvent was proposed to preconcentrate terazosin. The performance of the microextraction method was improved by introducing a common ion of pyridinium IL into the sample solution. Due to the presence of the common ion, the solubility of IL significantly decreased. As a result, the phase separation successfully occurred even at high ionic strength, and the volume of the settled IL-phase was not influenced by variations in the ionic strength (up to 30% w/v). After preconcentration step, the enriched phase was introduced to the spectrofluorimeter for the determination of terazosin. The obtained results revealed that this system did not suffer from the limitations of that in conventional ionic-liquid microextraction. Under optimum experimental conditions, the proposed method provided a limit of detection (LOD) of 0.027 μg L(-1) and a relative standard deviation (R.S.D.) of 2.4%. The present method was successfully applied to terazosin determination in actual pharmaceutical formulations and biological samples. Considering the large variety of ionic liquids, the proposed microextraction method earns many merits, and will present a wide application in the future.

  3. Quantitation of enniatins in biological samples of Wistar rats after oral administration by LC-MS/MS.

    Science.gov (United States)

    Escrivá, Laura; Font, Guillermina; Manyes, Lara

    2015-01-01

    The emerging Fusarium mycotoxins enniatins (ENNs) have diverse biological properties, mainly due to their ionophoric activity, and represent a potential risk to human and animal health since they are commonly found in food and feed. In vivo toxicity studies are scarce and limited to the major mycotoxins. Until now, any method for the simultaneous analysis of these compounds in plasma, serum and feces from rat has been reported. A method for the extraction and determination of ENNs A, A1, B and B1 from Wistar rat samples by liquid chromatography tandem mass spectrometry has been developed. The method was successfully validated with satisfactory recoveries (70-106%), good intraday (rat samples that were administered a mixture of ENNs containing 1.19, 2.16, 1.03 and 1.41 mg/kg body weight of ENN A, A1, B and B1, respectively. Blood, urine and feces samples collected every 2 h during the 8-h duration of the experiment were analyzed. The administered dose of the mixture of ENNs did not cause observable adverse effects on the animals. ENNs concentrations detected in serum and urine were below LOQs. The four ENNs were detected in feces reaching the maximum concentration at 6 h after administration.

  4. Sample Size Requirements for Estimation of Item Parameters in the Multidimensional Graded Response Model

    Directory of Open Access Journals (Sweden)

    Shengyu eJiang

    2016-02-01

    Full Text Available Likert types of rating scales in which a respondent chooses a response from an ordered set of response options are used to measure a wide variety of psychological, educational, and medical outcome variables. The most appropriate item response theory model for analyzing and scoring these instruments when they provide scores on multiple scales is the multidimensional graded response model (MGRM. A simulation study was conducted to investigate the variables that might affect item parameter recovery for the MGRM. Data were generated based on different sample sizes, test lengths, and scale intercorrelations. Parameter estimates were obtained through the flexiMIRT software. The quality of parameter recovery was assessed by the correlation between true and estimated parameters as well as bias and root- mean-square-error. Results indicated that for the vast majority of cases studied a sample size of N = 500 provided accurate parameter estimates, except for tests with 240 items when 1,000 examinees were necessary to obtain accurate parameter estimates. Increasing sample size beyond N = 1,000 did not increase the accuracy of MGRM parameter estimates.

  5. The Constitutive Content of the Crime of Refusal or Evasion from Collecting Biological Samples in the Romanian Criminal Law

    Directory of Open Access Journals (Sweden)

    Minodora-Ioana BĂLAN-RUSU

    2015-03-01

    Full Text Available In the paper we have examined the constitutive content of the offense of refusal or evasion from collecting biological samples, with elements of similarity and differences between the current and the old law. The comparative examination is useful as it allows the identification and application of a more favorable criminal law, in the case where such an offense is committed under the influence of the old law and it is to be finally judged after the entry into force of the new law. This work continues and completes the monograph “Offenses against traffic safety on public roads in the Romanian criminal law”, published in 2014 (Universul Juridic. The work can be useful to judicial bodies responsible for law enforcement, and academics from law schools (teachers, students and master students. The innovations consist in examining the constitutive content and the elements of similarity and differences between the two regulations.

  6. DEVELOPMENT OF UV-VISIBLE SPECTROPHOTOMETRIC METHOD FOR DETERMINATION OF DASATINIB IN PHARMACEUTICAL FORMULATION AND BIOLOGICAL SAMPLES

    Directory of Open Access Journals (Sweden)

    B. Ramachandra

    2015-02-01

    Full Text Available A simple, economical, accurate, precise and reproducible UV-Visible spectrophotometric method for the routine estimation of dasatinib has been developed. The method is based on the formation of a bluish green colored complex by dasatinib in presence of MBTH reagent. The developed colored complex showed λmax at 630 nm. Beer’s law in the concentration range of 10 to 60 μg/ ml. Results of analysis were authenticated statistically as well as by recovery studies, which gave mean recovery between 99 to 100%. The method was successful in determining dasatinib in pharmaceutical formulation and biological samples, with an average recovery between 99 to 100 % respectively. The proposed method could find application to product development scientists in ongoing research; as well provide an additional tool for routine analysis of dasatinib.

  7. Graphene-Based Materials as Solid Phase Extraction Sorbent for Trace Metal Ions, Organic Compounds, and Biological Sample Preparation.

    Science.gov (United States)

    Ibrahim, Wan Aini Wan; Nodeh, Hamid Rashidi; Sanagi, Mohd Marsin

    2016-07-03

    Graphene is a new carbon-based material that is of interest in separation science. Graphene has extraordinary properties including nano size, high surface area, thermal and chemical stability, and excellent adsorption affinity to pollutants. Its adsorption mechanisms are through non-covalent interactions (π-π stacking, electrostatic interactions, and H-bonding) for organic compounds and covalent interactions for metal ions. These properties have led to graphene-based material becoming a desirable adsorbent in a popular sample preparation technique known as solid phase extraction (SPE). Numerous studies have been published on graphene applications in recent years, but few review papers have focused on its applications in analytical chemistry. This article focuses on recent preconcentration of trace elements, organic compounds, and biological species using SPE-based graphene, graphene oxide, and their modified forms. Solid phase microextraction and micro SPE (µSPE) methods based on graphene are discussed.

  8. Cloud point extraction for the determination of cadmium and lead in biological samples by graphite furnace atomic absorption spectrometry

    Science.gov (United States)

    Maranhão, Tatiane De A.; Borges, Daniel L. G.; da Veiga, Márcia A. M. S.; Curtius, Adilson J.

    2005-06-01

    The phase-separation phenomenon of non-ionic surfactants occurring in aqueous solution was used for the extraction of Cd and Pb from digested biological samples. After complexation with O,O-diethyldithiophosphate (DDTP) in hydrochloric acid medium, the analytes are quantitatively extracted to the phase rich in the non-ionic surfactant octylphenoxypolyethoxyethanol (Triton X-114) after centrifugation. Methanol acidified with 0.1 mol L-1 HNO3 was added to the surfactant-rich phase prior to its analysis by electrothermal atomic absorption spectrometry (ET AAS). The adopted concentrations for DDTP, Triton X-114 and hydrochloric acid were all optimized. Pyrolysis and atomization temperatures were optimized using the extracts and pyrolysis temperatures of 700 °C for both elements and atomization temperatures of 1400 and 1600 °C for cadmium and lead, respectively, were used without adding any modifier, which shows that considerable analyte stabilization is provided by the medium itself. A more detailed investigation was carried out to determine which components of the extract were responsible for the high thermal stability achieved and it revealed that the amount of DDTP added and the phosphorus content of the digested samples contributed significantly to this phenomenon. Detection limits (3σB) of 6 and 40 ng g-1, along with enrichment factors of 129 and 18 for Cd and Pb, respectively, were achieved. The proposed procedure was applied to the analysis of five certified biological reference materials after microwave-assisted acid digestion in a mixture of H2O2 and HNO3. Comparison with certified values was performed for accuracy evaluation, resulting in good agreement according to the t-test for a 95% confidence level. The high efficiency of cloud point extraction to carry out the determination of the studied analytes in complex matrices was, therefore, demonstrated.

  9. Cloud point extraction for the determination of cadmium and lead in biological samples by graphite furnace atomic absorption spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Maranhao, Tatiane de A. [Departamento de Quimica, Universidade Federal de Santa Catarina, 88040-900, Florianopolis, SC (Brazil); Borges, Daniel L.G. [Departamento de Quimica, Universidade Federal de Santa Catarina, 88040-900, Florianopolis, SC (Brazil)]. E-mail: daniel@qmc.ufsc.br; Veiga, Marcia A.M.S. da [Instituto de Quimica, Universidade de Sao Paulo, 05513-970, CP 26077, Sao Paulo, SP (Brazil); Curtius, Adilson J. [Departamento de Quimica, Universidade Federal de Santa Catarina, 88040-900, Florianopolis, SC (Brazil)

    2005-06-30

    The phase-separation phenomenon of non-ionic surfactants occurring in aqueous solution was used for the extraction of Cd and Pb from digested biological samples. After complexation with O,O-diethyldithiophosphate (DDTP) in hydrochloric acid medium, the analytes are quantitatively extracted to the phase rich in the non-ionic surfactant octylphenoxypolyethoxyethanol (Triton X-114) after centrifugation. Methanol acidified with 0.1 mol L{sup -1} HNO{sub 3} was added to the surfactant-rich phase prior to its analysis by electrothermal atomic absorption spectrometry (ET AAS). The adopted concentrations for DDTP, Triton X-114 and hydrochloric acid were all optimized. Pyrolysis and atomization temperatures were optimized using the extracts and pyrolysis temperatures of 700 deg. C for both elements and atomization temperatures of 1400 and 1600 deg. C for cadmium and lead, respectively, were used without adding any modifier, which shows that considerable analyte stabilization is provided by the medium itself. A more detailed investigation was carried out to determine which components of the extract were responsible for the high thermal stability achieved and it revealed that the amount of DDTP added and the phosphorus content of the digested samples contributed significantly to this phenomenon. Detection limits (3{sigma} {sub B}) of 6 and 40 ng g{sup -1}, along with enrichment factors of 129 and 18 for Cd and Pb, respectively, were achieved. The proposed procedure was applied to the analysis of five certified biological reference materials after microwave-assisted acid digestion in a mixture of H{sub 2}O{sub 2} and HNO{sub 3}. Comparison with certified values was performed for accuracy evaluation, resulting in good agreement according to the t-test for a 95% confidence level. The high efficiency of cloud point extraction to carry out the determination of the studied analytes in complex matrices was, therefore, demonstrated.

  10. Pre-Mission Input Requirements to Enable Successful Sample Collection by A Remote Field/EVA Team

    Science.gov (United States)

    Cohen, B. A.; Lim, D. S. S.; Young, K. E.; Brunner, A.; Elphic, R. E.; Horne, A.; Kerrigan, M. C.; Osinski, G. R.; Skok, J. R.; Squyres, S. W.; Saint-Jacques, D.; Heldmann, J. L.

    2016-01-01

    The FINESSE (Field Investigations to Enable Solar System Science and Exploration) team, part of the Solar System Exploration Virtual Institute (SSERVI), is a field-based research program aimed at generating strategic knowledge in preparation for human and robotic exploration of the Moon, near-Earth asteroids, Phobos and Deimos, and beyond. In contract to other technology-driven NASA analog studies, The FINESSE WCIS activity is science-focused and, moreover, is sampling-focused with the explicit intent to return the best samples for geochronology studies in the laboratory. We used the FINESSE field excursion to the West Clearwater Lake Impact structure (WCIS) as an opportunity to test factors related to sampling decisions. We examined the in situ sample characterization and real-time decision-making process of the astronauts, with a guiding hypothesis that pre-mission training that included detailed background information on the analytical fate of a sample would better enable future astronauts to select samples that would best meet science requirements. We conducted three tests of this hypothesis over several days in the field. Our investigation was designed to document processes, tools and procedures for crew sampling of planetary targets. This was not meant to be a blind, controlled test of crew efficacy, but rather an effort to explicitly recognize the relevant variables that enter into sampling protocol and to be able to develop recommendations for crew and backroom training in future endeavors.

  11. Improving the sampling strategy of the Joint Danube Survey 3 (2013) by means of multivariate statistical techniques applied on selected physico-chemical and biological data.

    Science.gov (United States)

    Hamchevici, Carmen; Udrea, Ion

    2013-11-01

    The concept of basin-wide Joint Danube Survey (JDS) was launched by the International Commission for the Protection of the Danube River (ICPDR) as a tool for investigative monitoring under the Water Framework Directive (WFD), with a frequency of 6 years. The first JDS was carried out in 2001 and its success in providing key information for characterisation of the Danube River Basin District as required by WFD lead to the organisation of the second JDS in 2007, which was the world's biggest river research expedition in that year. The present paper presents an approach for improving the survey strategy for the next planned survey JDS3 (2013) by means of several multivariate statistical techniques. In order to design the optimum structure in terms of parameters and sampling sites, principal component analysis (PCA), factor analysis (FA) and cluster analysis were applied on JDS2 data for 13 selected physico-chemical and one biological element measured in 78 sampling sites located on the main course of the Danube. Results from PCA/FA showed that most of the dataset variance (above 75%) was explained by five varifactors loaded with 8 out of 14 variables: physical (transparency and total suspended solids), relevant nutrients (N-nitrates and P-orthophosphates), feedback effects of primary production (pH, alkalinity and dissolved oxygen) and algal biomass. Taking into account the representation of the factor scores given by FA versus sampling sites and the major groups generated by the clustering procedure, the spatial network of the next survey could be carefully tailored, leading to a decreasing of sampling sites by more than 30%. The approach of target oriented sampling strategy based on the selected multivariate statistics can provide a strong reduction in dimensionality of the original data and corresponding costs as well, without any loss of information.

  12. Determination of As, Cd, Cu, Hg and Pb in biological samples by modern electrothermal atomic absorption spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Sardans, Jordi, E-mail: j.sardans@creaf.uab.ca [Ecophysiological and Global Change Unit CSIC-CREAF, Edifici C, Universitat Autonoma de Barcelona, Bellaterra 08193, Barcelona (Spain); Montes, Fernando [Departamento de Ciencias Analiticas, Facultad de Ciencias, Universidad Nacional de Educacion a Distancia (UNED), C/ Senda del Rey 9. 28040 Madrid (Spain); Penuelas, Josep [Ecophysiological and Global Change Unit CSIC-CREAF, Edifici C, Universitat Autonoma de Barcelona, Bellaterra 08193, Barcelona (Spain)

    2010-02-15

    of this technique that reaches figures of merit equivalent to Inductively coupled plasma mass spectrometry (ICP-MS). Herein is presented an overview of recent advances and applications of (ETAAS) for the determination of As, Cd, Cu, Hg and Pb in biological samples drawn from studies over the last decade.

  13. Quantum Measurements for Graph Isomorphism Require Entanglement: Tight Results on Multiregister Fourier Sampling

    CERN Document Server

    Moore, Cristopher; Moore, Cristopher; Russell, Alexander

    2005-01-01

    Recently, Moore, Russell and Schulman showed that quantum measurements of single coset states in the symmetric group yield exponentially little information about the Hidden Subgroup Problem in the case relevant to Graph Isomorphism. Extending their techniques to multiregister Fourier sampling, Moore and Russell showed that entangled measurements over pairs of registers yield superpolynomially little information, and conjectured that entangled measurements over $\\Theta(n \\log n)$ registers are necessary. Here we prove this conjecture. This significantly restricts the types of possible quantum algorithms for Graph Isomorphism.

  14. Evaluation of non-invasive biological samples to monitor Staphylococcus aureus colonization in great apes and lemurs.

    Directory of Open Access Journals (Sweden)

    Frieder Schaumburg

    Full Text Available INTRODUCTION: Reintroduction of endangered animals as part of conservational programs bears the risk of importing human pathogens from the sanctuary to the natural habitat. One bacterial pathogen that serves as a model organism to analyze this transmission is Staphylococcus aureus as it can colonize and infect both humans and animals. The aim of this study was to evaluate the utility of various biological samples to monitor S. aureus colonization in great apes and lemurs. METHODS: Mucosal swabs from wild lemurs (n=25, Kirindy, Madagascar, feces, oral and genital swabs from captive chimpanzees (n=58, Ngamba and Entebbe, Uganda and fruit wadges and feces from wild chimpanzees (n=21, Taï National Parc, Côte d'Ivoire were screened for S. aureus. Antimicrobial resistance and selected virulence factors were tested for each isolate. Sequence based genotyping (spa typing, multilocus sequence typing was applied to assess the population structure of S. aureus. RESULTS: Oro-pharyngeal carriage of S. aureus was high in lemurs (72%, n=18 and captive chimpanzees (69.2%, n=27 and 100%, n=6, respectively. Wild chimpanzees shed S. aureus through feces (43.8, n=7 and fruit wadges (54.5, n=12. Analysis of multiple sampling revealed that two samples are sufficient to detect those animals which shed S. aureus through feces or fruit wadges. Genotyping showed that captive animals are more frequently colonized with human-associated S. aureus lineages. CONCLUSION: Oro-pharyngeal swabs are useful to screen for S. aureus colonization in apes and lemurs before reintroduction. Duplicates of stool and fruit wadges reliably detect S. aureus shedding in wild chimpanzees. We propose to apply these sampling strategies in future reintroduction programs to screen for S. aureus colonization. They may also be useful to monitor S. aureus in wild populations.

  15. X-ray holographic microscopy with zone plates applied to biological samples in the water window using 3rd harmonic radiation from the free-electron laser FLASH.

    Science.gov (United States)

    Gorniak, T; Heine, R; Mancuso, A P; Staier, F; Christophis, C; Pettitt, M E; Sakdinawat, A; Treusch, R; Guerassimova, N; Feldhaus, J; Gutt, C; Grübel, G; Eisebitt, S; Beyer, A; Gölzhäuser, A; Weckert, E; Grunze, M; Vartanyants, I A; Rosenhahn, A

    2011-06-06

    The imaging of hydrated biological samples - especially in the energy window of 284-540 eV, where water does not obscure the signal of soft organic matter and biologically relevant elements - is of tremendous interest for life sciences. Free-electron lasers can provide highly intense and coherent pulses, which allow single pulse imaging to overcome resolution limits set by radiation damage. One current challenge is to match both the desired energy and the intensity of the light source. We present the first images of dehydrated biological material acquired with 3rd harmonic radiation from FLASH by digital in-line zone plate holography as one step towards the vision of imaging hydrated biological material with photons in the water window. We also demonstrate the first application of ultrathin molecular sheets as suitable substrates for future free-electron laser experiments with biological samples in the form of a rat fibroblast cell and marine biofouling bacteria Cobetia marina.

  16. Requirements for representative sampling for fluvial fish assemblages – literary review

    Directory of Open Access Journals (Sweden)

    Potyó, I.

    2012-12-01

    Full Text Available Fish are good indicators of long-term changes of fluvial ecosystems therefore, assessment of fish assemblages is frequently used in evaluation of the ecological status of surface waters, especially since the implementation of the EU Water Framework Directive. Long-term changes of fish fauna and old-time abundance of fish populations in the Danube can be documented by historical data of fisheries. Direct detection of long-term changes of fish populations in large rivers is a difficult task due to large-scale temporal and spatial variability of fish distribution. The present study provides a review of river fish sampling methods, with special attention to approaches based on electrofishing. Our goal is to develop a standard monitoring method in large rivers to get more reliable and consistent data for description of long-term changes of fish populations.

  17. 77 FR 26162 - Amendments to Sterility Test Requirements for Biological Products

    Science.gov (United States)

    2012-05-03

    ... adopt the suggested language or revise the rule in light of the suggested language because the concerns....'' (76 FR 36019 at 36022) One commenter stated that this language is inconsistent with the harmonized... contain the appropriate controls to evaluate the product sample's potential to generate false-positive...

  18. Cloud point extraction and flame atomic absorption spectrometry combination for copper(II) ion in environmental and biological samples

    Energy Technology Data Exchange (ETDEWEB)

    Shokrollahi, Ardeshir [Chemistry Department, Yasouj University, Yasouj 75914-353 (Iran, Islamic Republic of)], E-mail: ashokrollahi@mail.yu.ac.ir; Ghaedi, Mehrorang [Chemistry Department, Yasouj University, Yasouj 75914-353 (Iran, Islamic Republic of)], E-mail: m_ghaedi@mail.yu.ac.ir; Hossaini, Omid; Khanjari, Narges [Chemistry Department, Yasouj University, Yasouj 75914-353 (Iran, Islamic Republic of); Soylak, Mustafa [Chemistry Department, University of Erciyes, 38039 Kayseri (Turkey)

    2008-12-30

    A cloud point extraction procedure was presented for the preconcentration of copper(II) ion in various samples. After complexation by 4-(phenyl diazenyl) benzene-1,3-diamine (PDBDM) (chrysoidine), copper(II) ions were quantitatively recovered in Triton X-114 after centrifugation. 0.5 ml of methanol acidified with 1.0 mol L{sup -1} HNO{sub 3} was added to the surfactant-rich phase prior to its analysis by flame atomic absorption spectrometry (FAAS). The influence of analytical parameters including ligand, Triton X-114 and HNO{sub 3} concentrations, bath temperature, heating time, centrifuge rate and time were optimized. The effect of the matrix ions on the recovery of copper(II) ions was investigated. The detection limit (3S.D.{sub b}/m, n = 10) of 0.6 ng mL{sup -1} along with preconcentration factor of 30 and enrichment factor of 41.1 with R.S.D. of 1.0% for Cu was achieved. The proposed procedure was applied to the analysis of various environmental and biological samples.

  19. Towards a system level understanding of non-model organisms sampled from the environment: a network biology approach.

    Science.gov (United States)

    Williams, Tim D; Turan, Nil; Diab, Amer M; Wu, Huifeng; Mackenzie, Carolynn; Bartie, Katie L; Hrydziuszko, Olga; Lyons, Brett P; Stentiford, Grant D; Herbert, John M; Abraham, Joseph K; Katsiadaki, Ioanna; Leaver, Michael J; Taggart, John B; George, Stephen G; Viant, Mark R; Chipman, Kevin J; Falciani, Francesco

    2011-08-01

    The acquisition and analysis of datasets including multi-level omics and physiology from non-model species, sampled from field populations, is a formidable challenge, which so far has prevented the application of systems biology approaches. If successful, these could contribute enormously to improving our understanding of how populations of living organisms adapt to environmental stressors relating to, for example, pollution and climate. Here we describe the first application of a network inference approach integrating transcriptional, metabolic and phenotypic information representative of wild populations of the European flounder fish, sampled at seven estuarine locations in northern Europe with different degrees and profiles of chemical contaminants. We identified network modules, whose activity was predictive of environmental exposure and represented a link between molecular and morphometric indices. These sub-networks represented both known and candidate novel adverse outcome pathways representative of several aspects of human liver pathophysiology such as liver hyperplasia, fibrosis, and hepatocellular carcinoma. At the molecular level these pathways were linked to TNF alpha, TGF beta, PDGF, AGT and VEGF signalling. More generally, this pioneering study has important implications as it can be applied to model molecular mechanisms of compensatory adaptation to a wide range of scenarios in wild populations.

  20. Highly selective ionic liquid-based microextraction method for sensitive trace cobalt determination in environmental and biological samples

    Energy Technology Data Exchange (ETDEWEB)

    Berton, Paula [Analytical Chemistry Research and Development Group (QUIANID), (LISAMEN - CCT - CONICET - Mendoza), Av. Ruiz Leal S/N Parque General San Martin, M 5502 IRA Mendoza (Argentina); Wuilloud, Rodolfo G., E-mail: rwuilloud@mendoza-conicet.gov.ar [Analytical Chemistry Research and Development Group (QUIANID), (LISAMEN - CCT - CONICET - Mendoza), Av. Ruiz Leal S/N Parque General San Martin, M 5502 IRA Mendoza (Argentina); Instituto de Ciencias Basicas, Universidad Nacional de Cuyo, Mendoza (Argentina)

    2010-03-10

    A simple and rapid dispersive liquid-liquid microextraction procedure based on an ionic liquid (IL-DLLME) was developed for selective determination of cobalt (Co) with electrothermal atomic absorption spectrometry (ETAAS) detection. Cobalt was initially complexed with 1-nitroso-2-naphtol (1N2N) reagent at pH 4.0. The IL-DLLME procedure was then performed by using a few microliters of the room temperature ionic liquid (RTIL) 1-hexyl-3-methylimidazolium hexafluorophosphate [C{sub 6}mim][PF{sub 6}] as extractant while methanol was the dispersant solvent. After microextraction procedure, the Co-enriched RTIL phase was solubilized in methanol and directly injected into the graphite furnace. The effect of several variables on Co-1N2N complex formation, extraction with the dispersed RTIL phase, and analyte detection with ETAAS, was carefully studied in this work. An enrichment factor of 120 was obtained with only 6 mL of sample solution and under optimal experimental conditions. The resultant limit of detection (LOD) was 3.8 ng L{sup -1}, while the relative standard deviation (RSD) was 3.4% (at 1 {mu}g L{sup -1} Co level and n = 10), calculated from the peak height of absorbance signals. The accuracy of the proposed methodology was tested by analysis of a certified reference material. The method was successfully applied for the determination of Co in environmental and biological samples.

  1. Towards a system level understanding of non-model organisms sampled from the environment: a network biology approach.

    Directory of Open Access Journals (Sweden)

    Tim D Williams

    2011-08-01

    Full Text Available The acquisition and analysis of datasets including multi-level omics and physiology from non-model species, sampled from field populations, is a formidable challenge, which so far has prevented the application of systems biology approaches. If successful, these could contribute enormously to improving our understanding of how populations of living organisms adapt to environmental stressors relating to, for example, pollution and climate. Here we describe the first application of a network inference approach integrating transcriptional, metabolic and phenotypic information representative of wild populations of the European flounder fish, sampled at seven estuarine locations in northern Europe with different degrees and profiles of chemical contaminants. We identified network modules, whose activity was predictive of environmental exposure and represented a link between molecular and morphometric indices. These sub-networks represented both known and candidate novel adverse outcome pathways representative of several aspects of human liver pathophysiology such as liver hyperplasia, fibrosis, and hepatocellular carcinoma. At the molecular level these pathways were linked to TNF alpha, TGF beta, PDGF, AGT and VEGF signalling. More generally, this pioneering study has important implications as it can be applied to model molecular mechanisms of compensatory adaptation to a wide range of scenarios in wild populations.

  2. Spectrophotometric determination of Sb(III) and Sb(V) in biological samples after micelle-mediated extraction.

    Science.gov (United States)

    Madrakian, Tayyebeh; Bozorgzadeh, Elaheh

    2009-10-30

    This work presents a micelle-mediated extraction method for simultaneous preconcentration and determination of Sb(III) and Sb(V) species in biological samples as a prior preconcentration step to their spectrophotometric determination. The analytical system is based on the selective reaction between Sb(III) and bromopyrogallol red (BPR) in the presence of cetyltrimethylammonium bromide (CTAB) and potassium iodide at pH 6.4. Total Sb concentration was determined after reduction of Sb(V) to Sb(III) in the presence of potassium iodide and ascorbic acid. The optimal extraction and reaction conditions were studied and the analytical characteristics of the method (e.g., limit of detection, linear range, preconcentration factor, and improvement factors) were obtained. Linearity for Sb(III) and Sb(V) were obeyed in the range of 0.2-20.0 ng mL(-1) and 0.4-25.0 ng mL(-1), respectively. The detection limit for the determination of Sb(III) and Sb(V) were 0.05 ng mL(-1) and 0.08 ng mL(-1), respectively. The interference effect of some anions and cations was also studied. The method was applied to the determination of Sb(III) in the presence of Sb(V) and total antimony in blood plasma and urine samples.

  3. Determination of haloperidol in biological samples using molecular imprinted polymer nanoparticles followed by HPLC-DAD detection.

    Science.gov (United States)

    Ebrahimzadeh, Homeira; Dehghani, Zahra; Asgharinezhad, Ali Akbar; Shekari, Nafiseh; Molaei, Karam

    2013-09-10

    In this study an extraction procedure using molecular imprinted polymer nanoparticles for the determination of haloperidol in biological samples is proposed. The haloperidol imprinted polymer nanoparticles were synthesized successfully by precipitation polymerization in a flask containing haloperidol as a template, ethyleneglycoldimethacrylate as a crosslinking agent, methacrylic acid as a functional monomer, and 2,2'-azobisisobutyronitrile as an initiator. The leached and unleached polymer nanoparticles have been characterized by infrared spectroscopy and scanning electron microscopy. The effect of different variables such as the pH of solution, uptake and elution time, type, and the least amount of eluent for elution of haloperidol from polymer was evaluated. Extraction efficiencies more than 97% were obtained by elution of the polymer with 1.5 mL of methanol-acetic acid-trifluoroacetic acid 79.9:20:0.1. Under optimal conditions maximum adsorption capacity was obtained 153.84 mg g(-1). The detection limit of the proposed procedure was between 0.2 and 0.35 μg L(-1). Finally this method was applied to the determination of haloperidol in plasma and urine samples and satisfactory results were achieved (RSD<6.9%).

  4. Correlative 3D imaging: CLSM and FIB-SEM tomography using high-pressure frozen, freeze-substituted biological samples.

    Science.gov (United States)

    Lucas, Miriam S; Guenthert, Maja; Gasser, Philippe; Lucas, Falk; Wepf, Roger

    2014-01-01

    Correlative light and electron microscopy aims at combining data from different imaging modalities, ideally from the same area of the one sample, in order to achieve a more holistic view of the hierarchical structural organization of cells and tissues. Modern 3D imaging techniques opened up new possibilities to expand morphological studies into the third dimension at the nanometer scale. Here we present an approach to correlate 3D light microscopy data with volume data from focused ion beam-scanning electron microscopy. An adapted sample preparation method based on high-pressure freezing for structure preservation, followed by freeze-substitution for multimodal en bloc imaging, is described. It is based on including fluorescent labeling during freeze-substitution, which enables histological context description of the structure of interest by confocal laser scanning microscopy prior to high-resolution electron microscopy. This information can be employed to relocate the respective structure in the electron microscope. This approach is most suitable for targeted small 3D volume correlation and has the potential to extract statistically relevant data of structural details for systems biology.

  5. Biocompatible channels for field-flow fractionation of biological samples: correlation between surface composition and operating performance.

    Science.gov (United States)

    Roda, Barbara; Cioffi, Nicola; Ditaranto, Nicoletta; Zattoni, Andrea; Casolari, Sonia; Melucci, Dora; Reschiglian, Pierluigi; Sabbatini, Luigia; Valentini, Antonio; Zambonin, Pier Giorgio

    2005-02-01

    Biocompatible methods capable of rapid purification and fractionation of analytes from complex natural matrices are increasingly in demand, particularly at the forefront of biotechnological applications. Field-flow fractionation is a separation technique suitable for nano-sized and micro-sized analytes among which bioanalytes are an important family. The objective of this preliminary study is to start a more general approach to field-flow fractionation for bio-samples by investigation of the correlation between channel surface composition and biosample adhesion. For the first time we report on the use of X-ray photoelectron spectroscopy (XPS) to study the surface properties of channels of known performance. By XPS, a polar hydrophobic environment was found on PVC material commonly used as accumulation wall in gravitational field-flow fractionation (GrFFF), which explains the low recovery obtained when GrFFF was used to fractionate a biological sample such as Staphylococcus aureus. An increase in separation performance was obtained first by conditioning the accumulation wall with bovine serum albumin and then by using the ion-beam sputtering technique to cover the GrFFF channel surface with a controlled inert film. XPS analysis was also employed to determine the composition of membranes used in hollow-fiber flow field-flow fractionation (HF FlFFF). The results obtained revealed homogeneous composition along the HF FlFFF channel both before and after its use for fractionation of an intact protein such as ferritin.

  6. Regional insect inventories require long time, extensive spatial sampling and good will.

    Directory of Open Access Journals (Sweden)

    Simone Fattorini

    Full Text Available Understanding how faunistic knowledge develops is of paramount importance to correctly evaluate completeness of insect inventories and to plan future research at regional scale, yet this is an unexplored issue. Aim of this paper was to investigate the processes that lead to a complete species inventory at a regional level for a beetle family. The tenebionid beetles of Latium region (Italy were analysed as a case study representative of general situations. A comprehensive faunistic database including 3,561 records spanning from 1871 to 2010 was realized examining 25,349 museum specimens and published data. Accumulation curves and non-parametric estimators of species richness were applied to model increase in faunistic knowledge over time, through space and by collectors' number. Long time, large spatial extent and contribution of many collectors were needed to obtain a reliable species inventory. Massive sampling was not effective in recovering more species. Amateur naturalists (here called parafaunists were more efficient collectors than professional entomologists. Museum materials collected by parafaunists over long periods and large spatial extent resulted to be a cost effective source of faunistic information with small number of collected individuals. It is therefore important to valuate and facilitate the work of parafaunists as already suggested for parataxonomists. By contrast, massive collections by standardized techniques for ecological research seem to be of scarce utility in improving faunistic knowledge, but their value for faunistic studies may be enhanced if they are conducted in poorly surveyed areas.

  7. Mercury in Environmental and Biological Samples Using Online Combustion with Sequential Atomic Absorption and Fluorescence Measurements: A Direct Comparison of Two Fundamental Techniques in Spectrometry

    Science.gov (United States)

    Cizdziel, James V.

    2011-01-01

    In this laboratory experiment, students quantitatively determine the concentration of an element (mercury) in an environmental or biological sample while comparing and contrasting the fundamental techniques of atomic absorption spectrometry (AAS) and atomic fluorescence spectrometry (AFS). A mercury analyzer based on sample combustion,…

  8. METHODS FOR DETERMINING AGITATOR MIXING REQUIREMENTS FOR A MIXING & SAMPLING FACILITY TO FEED WTP (WASTE TREATMENT PLANT)

    Energy Technology Data Exchange (ETDEWEB)

    GRIFFIN PW

    2009-08-27

    The following report is a summary of work conducted to evaluate the ability of existing correlative techniques and alternative methods to accurately estimate impeller speed and power requirements for mechanical mixers proposed for use in a mixing and sampling facility (MSF). The proposed facility would accept high level waste sludges from Hanford double-shell tanks and feed uniformly mixed high level waste to the Waste Treatment Plant. Numerous methods are evaluated and discussed, and resulting recommendations provided.

  9. Soft robotic arm inspired by the octopus: I. From biological functions to artificial requirements.

    Science.gov (United States)

    Margheri, L; Laschi, C; Mazzolai, B

    2012-06-01

    Octopuses are molluscs that belong to the group Cephalopoda. They lack joints and rigid links, and as a result, their arms possess virtually limitless freedom of movement. These flexible appendages exhibit peculiar biomechanical features such as stiffness control, compliance, and high flexibility and dexterity. Studying the capabilities of the octopus arm is a complex task that presents a challenge for both biologists and roboticists, the latter of whom draw inspiration from the octopus in designing novel technologies within soft robotics. With this idea in mind, in this study, we used new, purposively developed methods of analysing the octopus arm in vivo to create new biologically inspired design concepts. Our measurements showed that the octopus arm can elongate by 70% in tandem with a 23% diameter reduction and exhibits an average pulling force of 40 N. The arm also exhibited a 20% mean shortening at a rate of 17.1 mm s(-1) and a longitudinal stiffening rate as high as 2 N (mm s)(-1). Using histology and ultrasounds, we investigated the functional morphology of the internal tissues, including the sinusoidal arrangement of the nerve cord and the local insertion points of the longitudinal and transverse muscle fibres. The resulting information was used to create novel design principles and specifications that can in turn be used in developing a new soft robotic arm.

  10. Processes and procedures for a worldwide biological samples distribution; product assurance and logistic activities to support the mice drawer system tissue sharing event

    Science.gov (United States)

    Benassai, Mario; Cotronei, Vittorio

    The Mice Drawer System (MDS) is a scientific payload developed by the Italian Space Agency (ASI), it hosted 6 mice on the International Space Station (ISS) and re-entered on ground on November 28, 2009 with the STS 129 at KSC. Linked to the MDS experiment, a Tissue Sharing Program (TSP), was developed in order to make available to 16 Payload Investigators (PI) (located in USA, Canada, EU -Italy, Belgium and Germany -and Japan) the biological samples coming from the mice. ALTEC SpA (a PPP owned by ASI, TAS-I and local institutions) was responsible to support the logistics aspects of the MDS samples for the first MDS mission, in the frame of Italian Space Agency (ASI) OSMA program (OSteoporosis and Muscle Atrophy). The TSP resulted in a complex scenario, as ASI, progressively, extended the original OSMA Team also to researchers from other ASI programs and from other Agencies (ESA, NASA, JAXA). The science coordination was performed by the University of Genova (UNIGE). ALTEC has managed all the logistic process with the support of a specialized freight forwarder agent during the whole shipping operation phases. ALTEC formalized all the steps from the handover of samples by the dissection Team to the packaging and shipping process in a dedicated procedure. ALTEC approached all the work in a structured way, performing: A study of the aspects connected to international shipments of biological samples. A coopera-tive work with UNIGE/ASI /PIs to identify all the needs of the various researchers and their compatibility. A complete revision and integration of shipment requirements (addresses, tem-peratures, samples, materials and so on). A complete definition of the final shipment scenario in terms of boxes, content, refrigerant and requirements. A formal approach to identification and selection of the most suited and specialized Freight Forwarder. A clear identification of all the processes from sample dissection by PI Team, sample processing, freezing, tube preparation

  11. High Performance Computing and Storage Requirements for Biological and Environmental Research Target 2017

    Energy Technology Data Exchange (ETDEWEB)

    Gerber, Richard [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States). National Energy Research Scientific Computing Center (NERSC); Wasserman, Harvey [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States). National Energy Research Scientific Computing Center (NERSC)

    2013-05-01

    The National Energy Research Scientific Computing Center (NERSC) is the primary computing center for the DOE Office of Science, serving approximately 4,500 users working on some 650 projects that involve nearly 600 codes in a wide variety of scientific disciplines. In addition to large-­scale computing and storage resources NERSC provides support and expertise that help scientists make efficient use of its systems. The latest review revealed several key requirements, in addition to achieving its goal of characterizing BER computing and storage needs.

  12. HPLC and TLC methods for analysis of [(18)F]FDG and its metabolites from biological samples.

    Science.gov (United States)

    Rokka, Johanna; Grönroos, Tove J; Viljanen, Tapio; Solin, Olof; Haaparanta-Solin, Merja

    2017-03-24

    The most used positron emission tomography (PET) tracer, 2-[(18)F]fluoro-2-deoxy-d-glucose ([(18)F]FDG), is a glucose analogue that is used to measure tissue glucose consumption. Traditionally, the Sokoloff model is the basis for [(18)F]FDG modeling. According to this model, [(18)F]FDG is expected to be trapped in a cell in the form of [(18)F]FDG-6-phosphate ([(18)F]FDG-6-P). However, several studies have shown that in tissues, [(18)F]FDG metabolism goes beyond [(18)F]FDG-6-P. Our aim was to develop radioHPLC and radioTLC methods for analysis of [(18)F]FDG metabolites from tissue samples. The radioHPLC method uses a sensitive on-line scintillation detector to detect radioactivity, and the radioTLC method employs digital autoradiography to detect the radioactivity distribution on a TLC plate. The HPLC and TLC methods were developed using enzymatically in vitro-produced metabolites of [(18)F]FDG as reference standards. For this purpose, three [(18)F]FDG metabolites were synthesized: [(18)F]FDG-6-P, [(18)F]FD-PGL, and [(18)F]FDG-1,6-P2. The two methods were evaluated by analyzing the [(18)F]FDG metabolic profile from rodent ex vivo tissue homogenates. The HPLC method with an on-line scintillation detector had a wide linearity in a range of 5Bq-5kBq (LOD 46Bq, LOQ 139Bq) and a good resolution (Rs ≥1.9), and separated [(18)F]FDG and its metabolites clearly. The TLC method combined with digital autoradiography had a high sensitivity in a wide range of radioactivity (0.1Bq-2kBq, LOD 0.24Bq, LOQ 0.31Bq), and multiple samples could be analyzed simultaneously. As our test and the method validation with ex vivo samples showed, both methods are useful, and at best they complement each other in analysis of [(18)F]FDG and its radioactive metabolites from biological samples.

  13. Double-salting out assisted liquid-liquid extraction (SALLE) HPLC method for estimation of temozolomide from biological samples.

    Science.gov (United States)

    Jain, Darshana; Athawale, Rajani; Bajaj, Amrita; Shrikhande, Shruti

    2014-11-01

    The role of temozolomide (TMZ) in treatment of high grade gliomas, melanomas and other malignancies is being defined by the current clinical developmental trials. Temozolomide belongs to the group of alkylating agents and is prescribed to patients suffering from most aggressive forms of brain tumors. The estimation techniques for temozolomide from the extracted plasma or biological samples includes high-performance liquid chromatography with UV detection (HPLC-UV), micellar electrokinetic capillary chromatography (MKEC) and liquid chromatography coupled to mass spectroscopy (LC-MS). These methods suffer from disadvantages like low resolution, low sensitivity, low recovery or cost involvement. An analytical method possessing capacity to estimate low quantities of TMZ in plasma samples with high extraction efficiency (%) and high resolution with cost effectiveness needs to be developed. Cost effective, robust and low plasma component interfering HPLC method using salting out liquid-liquid extraction (SALLE) technique was developed and validated for estimation of drug from plasma samples. The extraction efficiency (%) with conventional LLE technique with methanol, ethyl acetate, dichloromethane and acetonitrile was found to be 5.99±2.45, 45.39±4.56, 46.04±1.14 and 46.23±3.67 respectively. Extraction efficiency (%) improved with SALLE where sodium chloride was used as an electrolyte and was found to be 6.80±5.56, 52.01±3.13, 62.69±2.11 and 69.20±1.18 with methanol, ethyl acetate, dichloromethane and acetonitrile as organic solvent. Upon utilization of two salts for extraction (double salting liquid-liquid extraction) the extraction efficiency (%) was further improved and was twice of LLE. It was found that double salting liquid-liquid extraction technique yielded extraction efficiency (%) of 11.71±5.66, 55.62±3.44, 77.28±2.89 and 87.75±0.89. Hence a method based on double SALLE was developed for quantification of TMZ demonstrating linearity in the range of

  14. Implementation of a semi-automated strategy for the annotation of metabolomic fingerprints generated by liquid chromatography-high resolution mass spectrometry from biological samples.

    Science.gov (United States)

    Courant, Frédérique; Royer, Anne-Lise; Chéreau, Sylvain; Morvan, Marie-Line; Monteau, Fabrice; Antignac, Jean-Philippe; Le Bizec, Bruno

    2012-11-07

    Metabolomics aims at detecting and semi-quantifying small molecular weight metabolites in biological samples in order to characterise the metabolic changes resulting from one or more given factors and/or to develop models based on diagnostic biomarker candidates. Nevertheless, whatever the objective of a metabolomic study, one critical step consists in the structural identification of mass spectrometric features revealed by statistical analysis and this remains a real challenge. Indeed, this requires both an understanding of the studied biological system, the correct use of various analytical information (retention time, molecular weight experimentally measured, isotopic golden rules, MS/MS fragment pattern interpretation…), or querying online databases. In gas chromatography-electro-ionisation (EI)-mass spectrometry, EI leads to a very reproducible fragmentation allowing establishment of universal EI mass spectra databases (for example, the NIST database -National Institute of Standards and Technology) and thus facilitates the identification step. Unfortunately, the situation is different when working with liquid chromatography-mass spectrometry (LC-MS) since atmospheric pressure ionisation exhibits high inter-instrument variability regarding fragmentation. Therefore, the constitution of LC-MS "in-house" spectral databases appears relevant in this context. The present study describes the procedure developed and applied to increment 133 and 130 metabolites in databanks dedicated to analyses performed with LC-HRMS in positive and negative electrospray ionisation, and the use of these databanks for annotating quickly untargeted metabolomics fingerprints. This study also describes the optimization of the parameters controlling the automatic processing in order to obtain a fast and reliable annotation of a maximum of organic compounds. This strategy was applied to bovine kidney samples collected from control animals or animals treated with steroid hormones. Thirty

  15. Simple determination of fluoride in biological samples by headspace solid-phase microextraction and gas chromatography-tandem mass spectrometry.

    Science.gov (United States)

    Kwon, Sun-Myung; Shin, Ho-Sang

    2015-08-14

    A simple and convenient method to detect fluoride in biological samples was developed. This method was based on derivatization with 2-(bromomethyl)naphthalene, headspace solid phase microextraction (HS-SPME) in a vial, and gas chromatography-tandem mass spectrometric detection. The HS-SPME parameters were optimized as follows: selection of CAR/PDMS fiber, 0.5% 2-(bromomethyl)naphthalene, 250 mg/L 15-crown-5-ether as a phase transfer catalyst, extraction and derivatization temperature of 95 °C, heating time of 20 min and pH of 7.0. Under the established conditions, the lowest limits of detection were 9 and 11 μg/L in 1.0 ml of plasma and urine, respectively, and the intra- and inter-day relative standard deviation was less than 7.7% at concentrations of 0.1 and 1.0 mg/L. The calibration curve showed good linearity of plasma and urine with r=0.9990 and r=0.9992, respectively. This method is simple, amenable to automation and environmentally friendly.

  16. FACE Analysis as a Fast and Reliable Methodology to Monitor the Sulfation and Total Amount of Chondroitin Sulfate in Biological Samples of Clinical Importance

    Directory of Open Access Journals (Sweden)

    Evgenia Karousou

    2014-06-01

    Full Text Available Glycosaminoglycans (GAGs due to their hydrophilic character and high anionic charge densities play important roles in various (pathophysiological processes. The identification and quantification of GAGs in biological samples and tissues could be useful prognostic and diagnostic tools in pathological conditions. Despite the noteworthy progress in the development of sensitive and accurate methodologies for the determination of GAGs, there is a significant lack in methodologies regarding sample preparation and reliable fast analysis methods enabling the simultaneous analysis of several biological samples. In this report, developed protocols for the isolation of GAGs in biological samples were applied to analyze various sulfated chondroitin sulfate- and hyaluronan-derived disaccharides using fluorophore-assisted carbohydrate electrophoresis (FACE. Applications to biologic samples of clinical importance include blood serum, lens capsule tissue and urine. The sample preparation protocol followed by FACE analysis allows quantification with an optimal linearity over the concentration range 1.0–220.0 µg/mL, affording a limit of quantitation of 50 ng of disaccharides. Validation of FACE results was performed by capillary electrophoresis and high performance liquid chromatography techniques.

  17. Public versus Private Drug Insurance and Outcomes of Patients Requiring Biologic Therapies for Inflammatory Bowel Disease

    Directory of Open Access Journals (Sweden)

    Amir Rumman

    2017-01-01

    Full Text Available Background. Antitumor necrosis factor (anti-TNF therapy is a highly effective but costly treatment for inflammatory bowel disease (IBD. Methods. We conducted a retrospective cohort study of IBD patients who were prescribed anti-TNF therapy (2007–2014 in Ontario. We assessed if the insurance type was a predictor of timely access to anti-TNF therapy and nonroutine health utilization (emergency department visits and hospitalizations. Results. There were 268 patients with IBD who were prescribed anti-TNF therapy. Public drug coverage was associated with longer median wait times to first dose than private one (56 versus 35 days, P=0.002. After adjusting for confounders, publicly insured patients were less likely to receive timely access to anti-TNF therapy compared with those privately insured (adjusted hazard ratio, 0.66; 95% CI: 0.45–0.95. After adjustment for demographic and clinical characteristics, publicly funded subjects were more than 2-fold more likely to require hospitalization (incidence rate ratio [IRR], 2.30; 95% CI: 1.19–4.43 and ED visits (IRR 2.42; 95% CI: 1.44–4.08 related to IBD. Conclusions. IBD patients in Ontario with public drug coverage experienced greater delays in access to anti-TNF therapy than privately insured patients and have a higher rate of hospitalizations and ED visits related to IBD.

  18. Public versus Private Drug Insurance and Outcomes of Patients Requiring Biologic Therapies for Inflammatory Bowel Disease

    Science.gov (United States)

    Rumman, Amir; Candia, Roberto; Sam, Justina J.; Croitoru, Kenneth; Silverberg, Mark S.; Steinhart, A. Hillary

    2017-01-01

    Background. Antitumor necrosis factor (anti-TNF) therapy is a highly effective but costly treatment for inflammatory bowel disease (IBD). Methods. We conducted a retrospective cohort study of IBD patients who were prescribed anti-TNF therapy (2007–2014) in Ontario. We assessed if the insurance type was a predictor of timely access to anti-TNF therapy and nonroutine health utilization (emergency department visits and hospitalizations). Results. There were 268 patients with IBD who were prescribed anti-TNF therapy. Public drug coverage was associated with longer median wait times to first dose than private one (56 versus 35 days, P = 0.002). After adjusting for confounders, publicly insured patients were less likely to receive timely access to anti-TNF therapy compared with those privately insured (adjusted hazard ratio, 0.66; 95% CI: 0.45–0.95). After adjustment for demographic and clinical characteristics, publicly funded subjects were more than 2-fold more likely to require hospitalization (incidence rate ratio [IRR], 2.30; 95% CI: 1.19–4.43) and ED visits (IRR 2.42; 95% CI: 1.44–4.08) related to IBD. Conclusions. IBD patients in Ontario with public drug coverage experienced greater delays in access to anti-TNF therapy than privately insured patients and have a higher rate of hospitalizations and ED visits related to IBD. PMID:28239601

  19. Three-dimensional temperature fields of the North Patagonian Sea recorded by Magellanic penguins as biological sampling platforms

    Science.gov (United States)

    Sala, Juan E.; Pisoni, Juan P.; Quintana, Flavio

    2017-04-01

    Temperature is a primary determinant of biogeographic patterns and ecosystem processes. Standard techniques to study the ocean temperature in situ are, however, particularly limited by their time and spatial coverage, problems which might be partially mitigated by using marine top predators as biological platforms for oceanographic sampling. We used small archival tags deployed on 33 Magellanic penguins (Spheniscus magellanicus), and obtained 21,070 geo-localized profiles of water temperature, during late spring of 2008, 2011, 2012 and 2013; in a region of the North Patagonian Sea with limited oceanographic records in situ. We compared our in situ data of sea surface temperature (SST) with those available from satellite remote sensing; to describe the three-dimensional temperature fields around the area of influence of two important tidal frontal systems; and to study the inter-annual variation in the three-dimensional temperature fields. There was a strong positive relationship between satellite- and animal-derived SST data although there was an overestimation by remote-sensing by a maximum difference of +2 °C. Little inter-annual variability in the 3-dimensional temperature fields was found, with the exception of 2012 (and to a lesser extent in 2013) where the SST was significantly higher. In 2013, we found weak stratification in a region which was unexpected. In addition, during the same year, a warm small-scale vortex is indicated by the animal-derived temperature data. This allowed us to describe and better understand the dynamics of the water masses, which, so far, have been mainly studied by remote sensors and numerical models. Our results highlight again the potential of using marine top predators as biological platforms to collect oceanographic data, which will enhance and accelerate studies on the Southwest Atlantic Ocean. In a changing world, threatened by climate change, it is urgent to fill information gaps on the coupled ocean-atmosphere system

  20. The requirement for proper storage of nuclear and related decommissioning samples to safeguard accuracy of tritium data

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Daeji, E-mail: kimdj@kins.re.kr [Korea Institute of Nuclear Safety, 19 Guseong, Yuseong, Daejeon, 303-338 (Korea, Republic of); Croudace, Ian W.; Warwick, Phillip E. [GAU-Radioanalytical, University of Southampton, NOC, European Way, Southampton SO14 3ZH (United Kingdom)

    2012-04-30

    Highlights: Black-Right-Pointing-Pointer Identification of variation in tritium loss rates in concrete samples. Black-Right-Pointing-Pointer Quantification of variation in tritium loss rates under different storage conditions. Black-Right-Pointing-Pointer Quantification of tritium cross-contamination rates for a range of matrix types. Black-Right-Pointing-Pointer Storage strategies for routine waste characterisation involving tritium. - Abstract: Large volumes of potentially tritium-contaminated waste materials are generated during nuclear decommissioning that require accurate characterisation prior to final waste sentencing. The practice of initially determining a radionuclide waste fingerprint for materials from an operational area is often used to save time and money but tritium cannot be included because of its tendency to be chemically mobile. This mobility demands a specific measurement for tritium and also poses a challenge in terms of sampling, storage and reliable analysis. This study shows that the extent of any tritium redistribution during storage will depend on its form or speciation and the physical conditions of storage. Any weakly or moderately bound tritium (e.g. adsorbed water, waters of hydration or crystallisation) may be variably lost at temperatures over the range 100-300 Degree-Sign C whereas for more strongly bound tritium (e.g. chemically bound or held in mineral lattices) the liberation temperature can be delayed up to 800 Degree-Sign C. For tritium that is weakly held the emanation behaviour at different temperatures becomes particularly important. The degree of {sup 3}H loss and cross-contamination that can arise after sampling and before analysis can be reduced by appropriate storage. Storing samples in vapour tight containers at the point of sampling, the use of triple enclosures, segregating high activity samples and using a freezer all lead to good analytical practice.

  1. Reduction of sample size requirements by bilateral versus unilateral research designs in animal models for cartilage tissue engineering.

    Science.gov (United States)

    Orth, Patrick; Zurakowski, David; Alini, Mauro; Cucchiarini, Magali; Madry, Henning

    2013-11-01

    Advanced tissue engineering approaches for articular cartilage repair in the knee joint rely on translational animal models. In these investigations, cartilage defects may be established either in one joint (unilateral design) or in both joints of the same animal (bilateral design). We hypothesized that a lower intraindividual variability following the bilateral strategy would reduce the number of required joints. Standardized osteochondral defects were created in the trochlear groove of 18 rabbits. In 12 animals, defects were produced unilaterally (unilateral design; n=12 defects), while defects were created bilaterally in 6 animals (bilateral design; n=12 defects). After 3 weeks, osteochondral repair was evaluated histologically applying an established grading system. Based on intra- and interindividual variabilities, required sample sizes for the detection of discrete differences in the histological score were determined for both study designs (α=0.05, β=0.20). Coefficients of variation (%CV) of the total histological score values were 1.9-fold increased following the unilateral design when compared with the bilateral approach (26 versus 14%CV). The resulting numbers of joints needed to treat were always higher for the unilateral design, resulting in an up to 3.9-fold increase in the required number of experimental animals. This effect was most pronounced for the detection of small-effect sizes and estimating large standard deviations. The data underline the possible benefit of bilateral study designs for the decrease of sample size requirements for certain investigations in articular cartilage research. These findings might also be transferred to other scoring systems, defect types, or translational animal models in the field of cartilage tissue engineering.

  2. Expanding comparative-advantage biological market models: contingency of mutualism on partners' resource requirements and acquisition trade-offs.

    Science.gov (United States)

    Hoeksema, Jason D; Schwartz, Mark W

    2003-05-01

    We expand the comparative-advantage biological market-modelling framework to show how differences between partners, both in their abilities to acquire two resources and in their requirements for those resources, can affect the net benefit of participating in interspecific resource exchange. In addition, the benefits derived from resource trading depend strongly on the nature of the trade-off between the acquisition of one resource and the acquisition of another, described here by the shape (linear, convex or concave) of the resource acquisition constraints of the individuals involved. Combined with previous results, these analyses provide a suite of predictions about whether or not resource exchange is beneficial for two heterospecific individuals relative to a strategy of non-interaction. The benefit derived from resource exchange depends on three factors: (i) relative differences between the partners in their resource acquisition abilities; (ii) relative differences between the partners in their resource requirements; and (iii) variation in the shape of resource acquisition trade-offs. We find that such an explicit consideration of resource requirements and acquisition abilities can provide useful and sometimes non-intuitive predictions about the benefits of resource exchange, and also which resources should be traded by which species.

  3. Scanning transmission ion microscopy mass measurements for quantitative trace element analysis within biological samples and validation using atomic force microscopy thickness measurements

    Science.gov (United States)

    Devès, Guillaume; Cohen-Bouhacina, Touria; Ortega, Richard

    2004-10-01

    We used the nuclear microprobe techniques, micro-PIXE (particle-induced X-ray emission), micro-RBS (Rutherford backscattering spectrometry) and scanning transmission ion microscopy (STIM) in order to perform the characterization of trace element content and spatial distribution within biological samples (dehydrated cultured cells, tissues). The normalization of PIXE results was usually expressed in terms of sample dry mass as determined by micro-RBS recorded simultaneously to micro-PIXE. However, the main limit of RBS mass measurement is the sample mass loss occurring during irradiation and which could be up to 30% of the initial sample mass. We present here a new methodology for PIXE normalization and quantitative analysis of trace element within biological samples based on dry mass measurement performed by mean of STIM. The validation of STIM cell mass measurements was obtained in comparison with AFM sample thickness measurements. Results indicated the reliability of STIM mass measurement performed on biological samples and suggested that STIM should be performed for PIXE normalization. Further information deriving from direct confrontation of AFM and STIM analysis could as well be obtained, like in situ measurements of cell specific gravity within cells compartment (nucleolus and cytoplasm).

  4. Scanning transmission ion microscopy mass measurements for quantitative trace element analysis within biological samples and validation using atomic force microscopy thickness measurements

    Energy Technology Data Exchange (ETDEWEB)

    Deves, Guillaume [Laboratoire de chimie nucleaire analytique et bioenvironnementale, UMR 5084, CNRS-Universite de Bordeaux 1, BP 120 Chemin du solarium, F33175 Gradignan cedex (France)]. E-mail: deves@cenbg.in2p3.fr; Cohen-Bouhacina, Touria [Centre de Physique Moleculaire Optique et Hertzienne, Universite de Bordeaux 1, 351, cours de la Liberation, F33405 Talence cedex (France); Ortega, Richard [Laboratoire de chimie nucleaire analytique et bioenvironnementale, UMR 5084, CNRS-Universite de Bordeaux 1, BP 120 Chemin du solarium, F33175 Gradignan cedex (France)

    2004-10-08

    We used the nuclear microprobe techniques, micro-PIXE (particle-induced X-ray emission), micro-RBS (Rutherford backscattering spectrometry) and scanning transmission ion microscopy (STIM) in order to perform the characterization of trace element content and spatial distribution within biological samples (dehydrated cultured cells, tissues). The normalization of PIXE results was usually expressed in terms of sample dry mass as determined by micro-RBS recorded simultaneously to micro-PIXE. However, the main limit of RBS mass measurement is the sample mass loss occurring during irradiation and which could be up to 30% of the initial sample mass. We present here a new methodology for PIXE normalization and quantitative analysis of trace element within biological samples based on dry mass measurement performed by mean of STIM. The validation of STIM cell mass measurements was obtained in comparison with AFM sample thickness measurements. Results indicated the reliability of STIM mass measurement performed on biological samples and suggested that STIM should be performed for PIXE normalization. Further information deriving from direct confrontation of AFM and STIM analysis could as well be obtained, like in situ measurements of cell specific gravity within cells compartment (nucleolus and cytoplasm)

  5. On the effect of experimental noise on the classification of biological samples using Raman micro-spectroscopy

    Science.gov (United States)

    Barton, Sinead J.; Kerr, Laura T.; Domijan, Katarina; Hennelly, Bryan M.

    2016-04-01

    Raman micro-spectroscopy is an optoelectronic technique that can be used to evaluate the chemical composition of biological samples and has been shown to be a powerful diagnostic tool for the investigation of various cancer related diseases including bladder, breast, and cervical cancer. Raman scattering is an inherently weak process with approximately 1 in 107 photons undergoing scattering and for this reason, noise from the recording system can have a significant impact on the quality of the signal, and its suitability for diagnostic classification. The main sources of noise in the recorded signal are shot noise, CCD dark current, and CCD readout noise. Shot noise results from the low signal photon count while dark current results from thermally generated electrons in the semiconductor pixels. Both of these noise sources are time dependent; readout noise is time independent but is inherent in each individual recording and results in the fundamental limit of measurement, arising from the internal electronics of the camera. In this paper, each of the aforementioned noise sources are analysed in isolation, and used to experimentally validate a mathematical model. This model is then used to simulate spectra that might be acquired under various experimental conditions including the use of different cameras, different source wavelength, and power etc. Simulated noisy datasets of T24 and RT112 cell line spectra are generated based on true cell Raman spectrum irradiance values (recorded using very long exposure times) and the addition of simulated noise. These datasets are then input to multivariate classification using Principal Components Analysis and Linear Discriminant Analysis. This method enables an investigation into the effect of noise on the sensitivity and specificity of Raman based classification under various experimental conditions and using different equipment.

  6. Target and non-target screening strategies for organic contaminants, residues and illicit substances in food , environmental and human biological samples by UHPLC-QTOF-MS

    OpenAIRE

    Hernández Hernández, Félix; Díaz San Pedro, Ramón; Sancho Llopis, Juan Vicente; Ibáñez Martínez, María

    2012-01-01

    In this paper, we illustrate the potential of ultra-high performance liquid chromatography (UHPLC) coupled with hybrid quadrupole time-of-flight mass spectrometry (QTOF MS) for large scale screening of organic contaminants in different types of samples. Thanks to the full-spectrum acquisition at satisfactory sensitivity, it is feasible to apply both (post)-target and non-target approaches for the rapid qualitative screening of organic pollutants in food, biological and environmental samples. ...

  7. Distance sampling to estimate abundance of biological populations : protocol for distance sampling surveys of coyotes at the Rocky Mountain Arsenal NWR

    Data.gov (United States)

    US Fish and Wildlife Service, Department of the Interior — Protocol for distance sampling surveys of coyotes at the Rocky Mountain Arsenal National Wildlife Refuge (RMA). Line transects are used to estimate the density of...

  8. Efficient synthesis of narrowly dispersed hydrophilic and magnetic molecularly imprinted polymer microspheres with excellent molecular recognition ability in a real biological sample.

    Science.gov (United States)

    Zhao, Man; Zhang, Cong; Zhang, Ying; Guo, Xianzhi; Yan, Husheng; Zhang, Huiqi

    2014-02-28

    A facile and highly efficient approach to obtain narrowly dispersed hydrophilic and magnetic molecularly imprinted polymer microspheres with molecular recognition ability in a real biological sample as good as what they show in the organic solvent-based media is described for the first time.

  9. Precision and accuracy in the quantitative analysis of biological samples by accelerator mass spectrometry: application in microdose absolute bioavailability studies.

    Science.gov (United States)

    Gao, Lan; Li, Jing; Kasserra, Claudia; Song, Qi; Arjomand, Ali; Hesk, David; Chowdhury, Swapan K

    2011-07-15

    Determination of the pharmacokinetics and absolute bioavailability of an experimental compound, SCH 900518, following a 89.7 nCi (100 μg) intravenous (iv) dose of (14)C-SCH 900518 2 h post 200 mg oral administration of nonradiolabeled SCH 900518 to six healthy male subjects has been described. The plasma concentration of SCH 900518 was measured using a validated LC-MS/MS system, and accelerator mass spectrometry (AMS) was used for quantitative plasma (14)C-SCH 900518 concentration determination. Calibration standards and quality controls were included for every batch of sample analysis by AMS to ensure acceptable quality of the assay. Plasma (14)C-SCH 900518 concentrations were derived from the regression function established from the calibration standards, rather than directly from isotopic ratios from AMS measurement. The precision and accuracy of quality controls and calibration standards met the requirements of bioanalytical guidance (U.S. Department of Health and Human Services, Food and Drug Administration, Center for Drug Evaluation and Research, Center for Veterinary Medicine. Guidance for Industry: Bioanalytical Method Validation (ucm070107), May 2001. http://www.fda.gov/downloads/Drugs/GuidanceCompilanceRegulatoryInformation/Guidances/ucm070107.pdf ). The AMS measurement had a linear response range from 0.0159 to 9.07 dpm/mL for plasma (14)C-SCH 900158 concentrations. The CV and accuracy were 3.4-8.5% and 94-108% (82-119% for the lower limit of quantitation (LLOQ)), respectively, with a correlation coefficient of 0.9998. The absolute bioavailability was calculated from the dose-normalized area under the curve of iv and oral doses after the plasma concentrations were plotted vs the sampling time post oral dose. The mean absolute bioavailability of SCH 900518 was 40.8% (range 16.8-60.6%). The typical accuracy and standard deviation in AMS quantitative analysis of drugs from human plasma samples have been reported for the first time, and the impact of these

  10. Evaluation of toxic metals in biological samples (scalp hair, blood and urine) of steel mill workers by electrothermal atomic absorption spectrometry.

    Science.gov (United States)

    Afridi, Hassan I; Kazi, Tasneem G; Jamali, Mohammad K; Kazi, Gul H; Arain, Mohammad B; Jalbani, Nusrat; Shar, Ghulam Q; Sarfaraz, Raja A

    2006-10-01

    The determination of toxic metals in the biological samples of human beings is an important clinical screening procedure. This study aimed to assess the possible influence of environmental exposure on production workers (PW) and quality control workers (QCW) of a steel mill, all male subjects aged 25-55 years. In this investigation, the concentrations of Pb, Cd, Ni and Cr were determined in biological samples (blood, urine and scalp hair samples) from these steel mill workers in relation to controlled unexposed healthy subjects of the same age group. After pre-treatment with nitric acid-hydrogen peroxide, the samples were digested via a microwave oven, and for comparison purposes, the same samples were digested by the conventional wet acid digestion method. The samples digested were subjected to graphite furnace atomic absorption spectrometry (GFAAS). To assess the reliability of these methods, critical factors, such as detection limit(s), calibration range(s), accuracy and precision, were studied. Quality control for these procedures was established with certified sample of human hair, urine and whole blood. The results indicate that the level of lead, cadmium and nickel in scalp hair, blood and urine samples were significantly higher in both groups of exposed workers (QW and PW) than those of the controls. The possible connection of these elements with the etiology of disease is discussed. The results also show the need for immediate improvements in workplace ventilation and industrial hygiene practices.

  11. Sample size requirements for studies of treatment effects on beta-cell function in newly diagnosed type 1 diabetes.

    Directory of Open Access Journals (Sweden)

    John M Lachin

    Full Text Available Preservation of β-cell function as measured by stimulated C-peptide has recently been accepted as a therapeutic target for subjects with newly diagnosed type 1 diabetes. In recently completed studies conducted by the Type 1 Diabetes Trial Network (TrialNet, repeated 2-hour Mixed Meal Tolerance Tests (MMTT were obtained for up to 24 months from 156 subjects with up to 3 months duration of type 1 diabetes at the time of study enrollment. These data provide the information needed to more accurately determine the sample size needed for future studies of the effects of new agents on the 2-hour area under the curve (AUC of the C-peptide values. The natural log(x, log(x+1 and square-root (√x transformations of the AUC were assessed. In general, a transformation of the data is needed to better satisfy the normality assumptions for commonly used statistical tests. Statistical analysis of the raw and transformed data are provided to estimate the mean levels over time and the residual variation in untreated subjects that allow sample size calculations for future studies at either 12 or 24 months of follow-up and among children 8-12 years of age, adolescents (13-17 years and adults (18+ years. The sample size needed to detect a given relative (percentage difference with treatment versus control is greater at 24 months than at 12 months of follow-up, and differs among age categories. Owing to greater residual variation among those 13-17 years of age, a larger sample size is required for this age group. Methods are also described for assessment of sample size for mixtures of subjects among the age categories. Statistical expressions are presented for the presentation of analyses of log(x+1 and √x transformed values in terms of the original units of measurement (pmol/ml. Analyses using different transformations are described for the TrialNet study of masked anti-CD20 (rituximab versus masked placebo. These results provide the information needed to

  12. "Shoot and Sense" Janus Micromotors-Based Strategy for the Simultaneous Degradation and Detection of Persistent Organic Pollutants in Food and Biological Samples.

    Science.gov (United States)

    Rojas, D; Jurado-Sánchez, B; Escarpa, A

    2016-04-05

    A novel Janus micromotor-based strategy for the direct determination of diphenyl phthalate (DPP) in food and biological samples is presented. Mg/Au Janus micromotors are employed as novel analytical platforms for the degradation of the non-electroactive DPP into phenol, which is directly measured by difference pulse voltammetry on disposable screen-printed electrodes. The self-movement of the micromotors along the samples result in the generation of hydrogen microbubbles and hydroxyl ions for DPP degradation. The increased fluid transport improves dramatically the analytical signal, increasing the sensitivity while lowering the detection potential. The method has been successfully applied to the direct analysis of DPP in selected food and biological samples, without any sample treatment and avoiding any potential contamination from laboratory equipment. The developed approach is fast (∼5 min) and accurate with recoveries of ∼100%. In addition, efficient propulsion of multiple Mg/Au micromotors in complex samples has also been demonstrated. The advantages of the micromotors-assisted technology, i.e., disposability, portability, and the possibility to carry out multiple analysis simultaneously, hold considerable promise for its application in food and biological control in analytical applications with high significance.

  13. The use of electrothermal vaporizer coupled to the inductively coupled plasma mass spectrometry for the determination of arsenic, selenium and transition metals in biological samples treated with formic acid

    Energy Technology Data Exchange (ETDEWEB)

    Tormen, Luciano, E-mail: lucianotormen@hotmail.com [Departamento de Quimica, Universidade Federal de Santa Catarina, Depto. Quimica, Campus Trindade, 88040-900 Florianopolis, SC (Brazil); Universidade Federal da Fronteira Sul - UFFS, Campus Laranjeiras do Sul, 85303-775 Laranjeiras do Sul, PR (Brazil); Gil, Raul A. [Instituto de Quimica de San Luis (UNSL-CONICET), Chacabuco y Pedernera, D5700BWQ San Luis (Argentina); Frescura, Vera L.A. [Departamento de Quimica, Universidade Federal de Santa Catarina, Depto. Quimica, Campus Trindade, 88040-900 Florianopolis, SC (Brazil); Martinez, Luis Dante [Instituto de Quimica de San Luis (UNSL-CONICET), Chacabuco y Pedernera, D5700BWQ San Luis (Argentina); Curtius, Adilson J. [Departamento de Quimica, Universidade Federal de Santa Catarina, Depto. Quimica, Campus Trindade, 88040-900 Florianopolis, SC (Brazil)

    2012-03-02

    Highlights: Black-Right-Pointing-Pointer Simple sample treatment of biologic samples with formic acid is proposed. Black-Right-Pointing-Pointer The treatment with formic acid is easy, rapid, less expensive and environmental friendly allowing a high sample throughput. Black-Right-Pointing-Pointer External calibration with aqueous standard allows the simultaneous determination of As, Co, Cu, Fe, Mn, Ni, Se and V. Black-Right-Pointing-Pointer The use of ETV avoids plasma instability, carbon deposit on the cones and does not require sample digestion. - Abstract: A fast method for the determination of As, Co, Cu, Fe, Mn, Ni, Se and V in biological samples by ETV-ICP-MS, after a simple sample treatment with formic acid, is proposed. Approximately 75 mg of each sample is mixed with 5 mL of formic acid, kept at 90 Degree-Sign C for 1 h and then diluted with nitric acid aqueous solution to a 5% (v/v) formic acid and 1% (v/v) nitric acid final concentrations. A palladium solution was used as a chemical modifier. The instrumental conditions, such as carrier gas flow rate, RF power, pyrolysis and vaporization temperatures and argon internal flow rate during vaporization were optimized. The formic acid causes a slight decrease of the analytes signal intensities, but does not increase the signal of the mainly polyatomic ions ({sup 14}N{sup 35}Cl{sup +}, {sup 14}N{sup 12}C{sup +}, {sup 40}Ar{sup 12}C{sup +}, {sup 13}C{sup 37}Cl{sup +}, {sup 40}Ar{sup 36}Ar{sup +}, {sup 40}Ar{sup 35}Cl{sup +}, {sup 35}Cl{sup 16}O{sup +}, {sup 40}Ar{sup 18}O{sup +}) that affect the analytes signals. The effect of charge transfer reactions, that could increase the ionization efficiency of some elements with high ionization potentials was not observed due to the elimination of most of the organic compounds during the pyrolysis step. External calibration with aqueous standard solutions containing 5% (v/v) formic acid allows the simultaneous determination of all analytes with high accuracy. The

  14. Development of a Univariate Membrane-Based Mid-Infrared Method for Protein Quantitation and Total Lipid Content Analysis of Biological Samples

    Directory of Open Access Journals (Sweden)

    Ivona Strug

    2014-01-01

    Full Text Available Biological samples present a range of complexities from homogeneous purified protein to multicomponent mixtures. Accurate qualification of such samples is paramount to downstream applications. We describe the development of an MIR spectroscopy-based analytical method offering simultaneous protein quantitation (0.25–5 mg/mL and analysis of total lipid or detergent species, as well as the identification of other biomolecules present in biological samples. The method utilizes a hydrophilic PTFE membrane engineered for presentation of aqueous samples in a dried format compatible with fast infrared analysis. Unlike classical quantification techniques, the reported method is amino acid sequence independent and thus applicable to complex samples of unknown composition. By comparison to existing platforms, this MIR-based method enables direct quantification using minimal sample volume (2 µL; it is well-suited where repeat access and limited sample size are critical parameters. Further, accurate results can be derived without specialized training or knowledge of IR spectroscopy. Overall, the simplified application and analysis system provides a more cost-effective alternative to high-throughput IR systems for research laboratories with minimal throughput demands. In summary, the MIR-based system provides a viable alternative to current protein quantitation methods; it also uniquely offers simultaneous qualification of other components, notably lipids and detergents.

  15. Gene-ontology enrichment analysis in two independent family-based samples highlights biologically plausible processes for autism spectrum disorders.

    LENUS (Irish Health Repository)

    Anney, Richard J L

    2012-02-01

    Recent genome-wide association studies (GWAS) have implicated a range of genes from discrete biological pathways in the aetiology of autism. However, despite the strong influence of genetic factors, association studies have yet to identify statistically robust, replicated major effect genes or SNPs. We apply the principle of the SNP ratio test methodology described by O\\'Dushlaine et al to over 2100 families from the Autism Genome Project (AGP). Using a two-stage design we examine association enrichment in 5955 unique gene-ontology classifications across four groupings based on two phenotypic and two ancestral classifications. Based on estimates from simulation we identify excess of association enrichment across all analyses. We observe enrichment in association for sets of genes involved in diverse biological processes, including pyruvate metabolism, transcription factor activation, cell-signalling and cell-cycle regulation. Both genes and processes that show enrichment have previously been examined in autistic disorders and offer biologically plausibility to these findings.

  16. Cryogenic coherent X-ray diffraction imaging of biological samples at SACLA: a correlative approach with cryo-electron and light microscopy.

    Science.gov (United States)

    Takayama, Yuki; Yonekura, Koji

    2016-03-01

    Coherent X-ray diffraction imaging at cryogenic temperature (cryo-CXDI) allows the analysis of internal structures of unstained, non-crystalline, whole biological samples in micrometre to sub-micrometre dimensions. Targets include cells and cell organelles. This approach involves preparing frozen-hydrated samples under controlled humidity, transferring the samples to a cryo-stage inside a vacuum chamber of a diffractometer, and then exposing the samples to coherent X-rays. Since 2012, cryo-coherent diffraction imaging (CDI) experiments have been carried out with the X-ray free-electron laser (XFEL) at the SPring-8 Ångstrom Compact free-electron LAser (SACLA) facility in Japan. Complementary use of cryo-electron microscopy and/or light microscopy is highly beneficial for both pre-checking samples and studying the integrity or nature of the sample. This article reports the authors' experience in cryo-XFEL-CDI of biological cells and organelles at SACLA, and describes an attempt towards reliable and higher-resolution reconstructions, including signal enhancement with strong scatterers and Patterson-search phasing.

  17. Magnetic metal-organic nanotubes: An adsorbent for magnetic solid-phase extraction of polychlorinated biphenyls from environmental and biological samples.

    Science.gov (United States)

    Li, Qiu-Lin; Wang, Lei-Lei; Wang, Xia; Wang, Ming-Lin; Zhao, Ru-Song

    2016-06-03

    A new type of three-dimensional, echinus-like magnetic Fe3O4 @ cobalt(Ⅱ)-based metal-organic nanotube (Fe3O4 @ Co-MONT) yolk-shell microspheres, have been designed and synthesized for the first time. Fe3O4 @ Co-MONTs yolk-shell microspheres were characterized by scanning electron micrographs, transmission electron microscopy, Fourier transform infrared spectra, X-ray diffraction, and vibrating sample magnetometry. The feasibility of the new material for use as an absorbent was investigated for magnetic solid phase-extraction (MSPE) of polychlorinated biphenyls (PCBs) from environmental water samples and biological samples. The Plackett-Burman design and Box-Behnken design were used to determine and optimize the extraction parameters influencing the extraction efficiency through response surface methodology. Under the optimized conditions, the developed method showed good linearity within the range of 5-1000ngL(-1), low limits of detection (0.31-0.49ngL(-1)), and good reproducibility (RSD<10%). The proposed method was successfully applied for the analysis of PCBs in real environmental water samples. These results demonstrated that Fe3O4 @ Co-MONTs is a promising adsorbent material for the MSPE of PCBs at trace levels from environmental water samples and biological samples.

  18. Matrix effects break the LC behavior rule for analytes in LC-MS/MS analysis of biological samples

    Science.gov (United States)

    High-performance liquid chromatography (HPLC) and liquid chromatography-tandem mass spectrometry (LC-MS/MS) are generally accepted as the preferred techniques for detecting and quantitating analytes of interest in biological matrices on the basis of the rule that one chemical compound yields one LC-...

  19. Determination of cobalt in biological samples by electrothermal atomic absorption spectrometry after extraction with 1,5-bis (di-2-pyridylmethylene) thiocarbohydrazide

    Energy Technology Data Exchange (ETDEWEB)

    Collado, G.; Bosch Ojeda, C.; Garcia de Torres, A.; Cano Pavon, J.M. [University of Malaga (Spain)

    1995-06-01

    A method for the determination of trace amounts of cobalt in biological samples by atomic absorption spectrometry with graphite furnace atomization extraction conditions were evaluated from a critical study of the effects of pH, concentration of extractant, shaking time and ionic strength. The detection limit for cobalt is 0.06 ng ml{sup -1} and the calibration is linear from 0.1 to 2.5 ng ml{sup -1}. The relative standard deviation for ten replicate measurements is 1.7 % for 0.5 ng ml{sup -1} of cobalt. The effect of interferences was studied and no interferences from the elements commonly found in biological materials were observed. The chief advantage of the method lies in its maximum allowable aqueous-to-organic phase volume ratio of 30:1. Results from the analysis of some certified biological reference materials are given. (authors). 14 refs., 1 figs., 3 tabs.

  20. Preconcentration and Determination of Mefenamic Acid in Pharmaceutical and Biological Fluid Samples by Polymer-grafted Silica Gel Solid-phase Extraction Following High Performance Liquid Chromatography

    OpenAIRE

    Bagheri Sadeghi, Hayedeh; Panahi, Homayon Ahmad; Mahabadi, Mahsa; Moniri, Elham

    2015-01-01

    Mefenamic acid is a nonsteroidal anti-inflammatory drug (NSAID) that has analgesic, anti-infammatory and antipyretic actions. It is used to relieve mild to moderate pains. Solid-phase extraction of mefenamic acid by a polymer grafted to silica gel is reported. Poly allyl glycidyl ether/iminodiacetic acid-co-N, N-dimethylacrylamide was synthesized and grafted to silica gel and was used as an adsorbent for extraction of trace mefenamic acid in pharmaceutical and biological samples. Different fa...

  1. Full-field quantitative phase imaging by white-light interferometry with active phase stabilization and its application to biological samples

    Science.gov (United States)

    Li, Xinhong; Yamauchi, Toyohiko; Iwai, Hidenao; Yamashita, Yutaka; Zhang, Haijun; Hiruma, Teruo

    2006-06-01

    We report a Koehler-illumination-based full-field, actively stabilized, low-coherence phase-shifting interferometer, which is built on a white-light Michelson interferometer. By using a phase-stepping technique we can obtain full-field phase images of the sample. An actively stabilized phase-lock circuit is employed in the system to reduce phase noise. An application to human epithelial cells (HeLa cells) is achieved in our experiment. The advancement of this technique rests in its ability to take images of unstained biological samples quantitatively and on a nanometer scale.

  2. Polymer monolithic capillary microextraction on-line coupled with inductively coupled plasma-mass spectrometry for the determination of trace Au and Pd in biological samples

    Energy Technology Data Exchange (ETDEWEB)

    Liu, Xiaolan; He, Man; Chen, Beibei; Hu, Bin, E-mail: binhu@whu.edu.cn

    2014-11-01

    A novel method based on on-line polymer monolithic capillary microextraction (CME)-inductively coupled plasma mass spectrometry (ICP-MS) was developed for the determination of trace Au and Pd in biological samples. For this purpose, poly(glycidyl methacrylate-ethylene dimethacrylate) monolith was prepared and functionalized with mercapto groups. The prepared monolith exhibited good selectivity to Au and Pd, and good resistance to strong acid with a long life span. Factors affecting the extraction efficiency of CME, such as sample acidity, sample flow rate, eluent conditions and coexisting ion interference were investigated in detail. Under the optimal conditions, the limits of detection (LODs, 3σ) were 5.9 ng L{sup −1} for Au and 8.3 ng L{sup −1} for Pd, and the relative standard deviations (RSDs, c = 50 ng L{sup −1}, n = 7) were 6.5% for Au and 1.1% for Pd, respectively. The developed method was successfully applied to the determination of Au and Pd in human urine and serum samples with the recovery in the range of 84–118% for spiked samples. The developed on-line polymer monolithic CME-ICP-MS method has the advantages of rapidity, simplicity, low sample/reagent consumption, high sensitivity and is suitable for the determination of trace Au and Pd in biological samples with limited amount available and complex matrix. - Highlights: • An on-line CME-ICP-MS method was developed for Au and Pd analysis in human fluids. • Poly(GMA-EDMA-SH) monolith exhibited good selectivity for Au/Pd and acid-resistance. • The method is rapid, simple, and sensitive with low sample/reagents consumption.

  3. Estimation of lead in biological samples of oral cancer patients chewing smokeless tobacco products by ionic liquid-based microextraction in a single syringe system.

    Science.gov (United States)

    Arain, Sadaf S; Kazi, Tasneem G; Arain, Asma J; Afridi, Hassan I; Arain, Muhammad B; Brahman, Kapil D; Naeemullah; Panhwar, Abdul H; Arain, Mariam S

    2015-08-01

    Several studies have reported that the chewing habit of smokeless tobacco (SLT) has been associated with oral cancer. The aim of the present study was to evaluate the trace levels of lead (Pb) in biological samples (blood, scalp hair) of oral cancer patients and referents of the same age group (range 30-60 years). As the concentrations of Pb are very low in biological samples, so a simple and efficient ionic liquid-based microextraction in a single syringe system has been developed, as a prior step to determination by flame atomic absorption spectrometry. In this procedure, the hydrophobic chelates of Pb with ammonium pyrrolidinedithiocarbamate (APDC) were extracted into fine droplets of 1-butyl-3-methylimidazolium hexafluorophosphate [C4MIM][PF6] within a syringe while using Triton X-114 as a dispersant. Factors influencing the microextraction efficiency and determination, such as pH of the sample, volume of [C4MIM][PF6] and Triton X-114, ligand concentration, and incubation time, were studied. To validate the proposed method, certified reference materials were analyzed and the results of Pb(2+) were in good agreement with certified values. At optimum experimental values of significant variables, detection limit and enhancement factor were found to be 0.412 μg/L and 80, respectively. The coexisting ions showed no obvious negative outcome on Pb preconcentration. The proposed method was applied satisfactorily for the preconcentration of Pb(2+) in acid-digested SLT and biological samples of the study population. It was observed that oral cancer patients who consumed different SLT products have 2-3-fold higher levels of Pb in scalp hair and blood samples as compared to healthy referents (p < 0.001). While 31.4-50.8% higher levels of Pb were observed in referents chewing different SLT products as compared to nonconsumers (p < 0.01).

  4. Fabrication of novel nanoporous array anodic alumina solid-phase microextraction fiber coating and its potential application for headspace sampling of biological volatile organic compounds

    Energy Technology Data Exchange (ETDEWEB)

    Zhang Zhuomin [School of Chemistry and Chemical Engineering, Sun Yat-sen University, Guangzhou 510275 (China); Wang Qingtang [Key Laboratory of Analysis and Detection for Food Safety of Ministry of Education, College of Chemistry and Chemical Engineering, Fuzhou University, Fuzhou, Fujian 350002 (China); Li Gongke, E-mail: cesgkl@mail.sysu.edu.cn [School of Chemistry and Chemical Engineering, Sun Yat-sen University, Guangzhou 510275 (China)

    2012-05-21

    Highlights: Black-Right-Pointing-Pointer Nanoporous array anodic alumina (NAAA) SPME coating was originally prepared. Black-Right-Pointing-Pointer NAAA SPME coating achieved excellent enrichment capability and selectivity for VOCs. Black-Right-Pointing-Pointer NAAA SPME coating can be applied for the headspace sampling of biological VOCs. - Abstract: In the study, nanoporous array anodic alumina (NAAA) prepared by a simple, rapid and stable two-step anodic oxidization method was introduced as a novel solid-phase microextraction (SPME) fiber coating. The regular nanoporous array structure and chemical composition of NAAA SPME fiber coating was characterized and validated by scanning electron microscopy and energy dispersive spectroscopy, respectively. Compared with the commercial polydimethylsiloxane (PDMS) SPME fiber coating, NAAA SPME fiber coating achieved the higher enrichment capability (1.7-4.7 folds) for the mixed standards of volatile organic compounds (VOCs). The selectivity for volatile alcohols by NAAA SPME fiber coating demonstrated an increasing trend with the increasing polarity of alcohols caused by the gradually shortening carbon chains from 1-undecanol to 1-heptanol or the isomerization of carbon chains of some typical volatile alcohols including 2-ethyl hexanol, 1-octanol, 2-phenylethanol, 1-phenylethanol, 5-undecanol, 2-undecanol and 1-undecanol. Finally, NAAA SPME fiber coating was originally applied for the analysis of biological VOCs of Bailan flower, stinkbug and orange peel samples coupled with gas chromatography-mass spectrometry (GC-MS) detection. Thirty, twenty-seven and forty-four VOCs of Bailan flower, stinkbug and orange peel samples were sampled and identified, respectively. Moreover, the contents of trace 1-octanol and nonanal of real orange peel samples were quantified for the further method validation with satisfactory recoveries of 106.5 and 120.5%, respectively. This work proposed a sensitive, rapid, reliable and convenient

  5. Implementación de un protocolo de actuación para toma de muestras biológicas en juicios de paternidad/Implementation of a protocol for sampling biological tasters in trials of paternity

    Directory of Open Access Journals (Sweden)

    Daniel De La Barrera Escamilla

    2015-01-01

    Full Text Available The scientific and technological advances in forensic research has resulted in recent years in the use of various scientific applications such as Forensic Genetic; the possibility that this area is critical to the identification of persons and the establishment of biological relationship. Since in Mexico, expert evidence on Molecular and Forensic Genetics used in in family and civil trial´s matters, in order to recognize the relationship between individuals has a little over 10 years to be used actively, it is necessary that forensic experts involved in these judgments have a sampling protocol to ensure technical and legally correct way sample collection; and ensure safekeeping and processing them in the laboratory, the aim of which is meet the new requirements of orality.

  6. How molecular should your molecular model be? On the level of molecular detail required to simulate biological networks in systems and synthetic biology.

    Science.gov (United States)

    Gonze, Didier; Abou-Jaoudé, Wassim; Ouattara, Djomangan Adama; Halloy, José

    2011-01-01

    The recent advance of genetic studies and the rapid accumulation of molecular data, together with the increasing performance of computers, led researchers to design more and more detailed mathematical models of biological systems. Many modeling approaches rely on ordinary differential equations (ODE) which are based on standard enzyme kinetics. Michaelis-Menten and Hill functions are indeed commonly used in dynamical models in systems and synthetic biology because they provide the necessary nonlinearity to make the dynamics nontrivial (i.e., limit-cycle oscillations or multistability). For most of the systems modeled, the actual molecular mechanism is unknown, and the enzyme equations should be regarded as phenomenological. In this chapter, we discuss the validity and accuracy of these approximations. In particular, we focus on the validity of the Michaelis-Menten function for open systems and on the use of Hill kinetics to describe transcription rates of regulated genes. Our discussion is illustrated by numerical simulations of prototype systems, including the Repressilator (a genetic oscillator) and the Toggle Switch model (a bistable system). We systematically compare the results obtained with the compact version (based on Michaelis-Menten and Hill functions) with its corresponding developed versions (based on "elementary" reaction steps and mass action laws). We also discuss the use of compact approaches to perform stochastic simulations (Gillespie algorithm). On the basis of these results, we argue that using compact models is suitable to model qualitatively biological systems.

  7. Preparation and evaluation of a novel molecularly imprinted polymer coating for selective extraction of indomethacin from biological samples by electrochemically controlled in-tube solid phase microextraction

    Energy Technology Data Exchange (ETDEWEB)

    Asiabi, Hamid [Department of Chemistry, Tarbiat Modares University, P.O. Box 14115-175, Tehran (Iran, Islamic Republic of); Yamini, Yadollah, E-mail: yyamini@modares.ac.ir [Department of Chemistry, Tarbiat Modares University, P.O. Box 14115-175, Tehran (Iran, Islamic Republic of); Seidi, Shahram; Ghahramanifard, Fazel [Department of Analytical Chemistry, Faculty of Chemistry, K.N. Toosi University of Technology, Tehran (Iran, Islamic Republic of)

    2016-03-24

    In the present work, an automated on-line electrochemically controlled in-tube solid-phase microextraction (EC-in-tube SPME) coupled with HPLC-UV was developed for the selective extraction and preconcentration of indomethacin as a model analyte in biological samples. Applying an electrical potential can improve the extraction efficiency and provide more convenient manipulation of different properties of the extraction system including selectivity, clean-up, rate, and efficiency. For more enhancement of the selectivity and applicability of this method, a novel molecularly imprinted polymer coated tube was prepared and applied for extraction of indomethacin. For this purpose, nanostructured copolymer coating consisting of polypyrrole doped with ethylene glycol dimethacrylate was prepared on the inner surface of a stainless-steel tube by electrochemical synthesis. The characteristics and application of the tubes were investigated. Electron microscopy provided a cross linked porous surface and the average thickness of the MIP coating was 45 μm. Compared with the non-imprinted polymer coated tubes, the special selectivity for indomethacin was discovered with the molecularly imprinted coated tube. Moreover, stable and reproducible responses were obtained without being considerably influenced by interferences commonly existing in biological samples. Under the optimal conditions, the limits of detection were in the range of 0.07–2.0 μg L{sup −1} in different matrices. This method showed good linearity for indomethacin in the range of 0.1–200 μg L{sup −1}, with coefficients of determination better than 0.996. The inter- and intra-assay precisions (RSD%, n = 3) were respectively in the range of 3.5–8.4% and 2.3–7.6% at three concentration levels of 7, 70 and 150 μg L{sup −1}. The results showed that the proposed method can be successfully applied for selective analysis of indomethacin in biological samples. - Graphical abstract: An automated on

  8. Critical comparison of radiometric and mass spectrometric methods for the determination of radionuclides in environmental, biological and nuclear waste samples

    DEFF Research Database (Denmark)

    Hou, Xiaolin; Roos, Per

    2008-01-01

    spectrometry, and glow discharge mass spectrometry are reviewed for the determination of radionuclides. These methods are critically compared for the determination of long-lived radionuclides important for radiation protection, decommissioning of nuclear facilities, repository of nuclear waste, tracer...... application in the environmental and biological researches, these radionuclides include H-3, C-14, Cl-36, Ca-41 Ni-59,Ni-63, Sr-89,Sr-90, Tc-99, I-129, Cs-135,Cs-137, Pb-210, Ra-226,Ra-228, Np-237, Am-241, and isotopes of thorium, uranium and plutonium. The application of on-line methods (flow injection...

  9. Sampling Size Required for Determining Soil Carbon and Nitrogen Properties at Early Establishment of Second Rotation Hoop Pine Plantations in Subtropical Australia

    Institute of Scientific and Technical Information of China (English)

    2007-01-01

    Investigations into forest soils face the problem of the high level of spatial variability that is an inherent property of all forest soils. In order to investigate the effect of changes in residue management practices on soil properties in hoop pine (Araucaria cunninghamii Aiton ex A. Cunn.) plantations of subtropical Australia it was important to understand the intensity of sampling effort required to overcome the spatial variability induced by those changes. Harvest residues were formed into windrows to prevent nitrogen (N) losses through volatilisation and erosion that had previously occurred as a result of pile and burn operations. We selected second rotation (2R) hoop pine sites where the windrows (10-15 m apart) had been formed 1, 2 and 3 years prior to sampling in order to examine the spatial variability in soil carbon (C)and N and in potential mineralisable N (PMN) in the areas beneath and between (inter-) the windrows. We examined the implications of soil variability on the number of samples required to detect differences in means for specific soil properties,at different ages and at specified levels of accuracy. Sample size needed to accurately reflect differences between means was not affected by the position where the samples were taken relative to the windrows but differed according to the parameter to be sampled. The relative soil sampling size required for detecting differences between means of a soil property in the inter-windrow and beneath-windrow positions was highly dependent on the soil property assessed and the acceptable relative sampling error. An alternative strategy for soil sampling should be considered, if the estimated sample size exceeds 50 replications. The possible solution to this problem is collection of composite soil samples allowing a substantial reduction in the number of samples required for chemical analysis without loss in the precision of the mean estimates for a particular soil property.

  10. Well-defined hydrophilic molecularly imprinted polymer microspheres for efficient molecular recognition in real biological samples by facile RAFT coupling chemistry.

    Science.gov (United States)

    Zhao, Man; Chen, Xiaojing; Zhang, Hongtao; Yan, Husheng; Zhang, Huiqi

    2014-05-12

    A facile and highly efficient new approach (namely RAFT coupling chemistry) to obtain well-defined hydrophilic molecularly imprinted polymer (MIP) microspheres with excellent specific recognition ability toward small organic analytes in the real, undiluted biological samples is described. It involves the first synthesis of "living" MIP microspheres with surface-bound vinyl and dithioester groups via RAFT precipitation polymerization (RAFTPP) and their subsequent grafting of hydrophilic polymer brushes by the simple coupling reaction of hydrophilic macro-RAFT agents (i.e., hydrophilic polymers with a dithioester end group) with vinyl groups on the "living" MIP particles in the presence of a free radical initiator. The successful grafting of hydrophilic polymer brushes onto the obtained MIP particles was confirmed by SEM, FT-IR, static contact angle and water dispersion studies, elemental analyses, and template binding experiments. Well-defined MIP particles with densely grafted hydrophilic polymer brushes (∼1.8 chains/nm(2)) of desired chemical structures and molecular weights were readily obtained, which showed significantly improved surface hydrophilicity and could thus function properly in real biological media. The origin of the high grafting densities of the polymer brushes was clarified and the general applicability of the strategy was demonstrated. In particular, the well-defined characteristics of the resulting hydrophilic MIP particles allowed the first systematic study on the effects of various structural parameters of the grafted hydrophilic polymer brushes on their water-compatibility, which is of great importance for rationally designing more advanced real biological sample-compatible MIPs.

  11. Using an international workshop to develop functional requirements and a Biohazard Assessment Protocol (BAP) with which to develop a preferred concept for a Mars Sample Return (MSR) Sample Receiving Facility (SRF).

    Science.gov (United States)

    Vrublevskis, John; Guest, Michael; Bennett, Allan; Walker, James; Smith, Caroline; Baker, Robert; Grant, Colin

    COSPAR Planetary Protection Policy places very stringent requirements on Sample Return missions and `breaking the chain of contact' between Earth and the celestial body from which the sample is returned. This must be continued after return to Earth and -at the same time-any contamination or damage to the sample must be avoided until such time as it can be confirmed as not presenting a biohazard and available for subsequent curation and scientific investigation. Such a facility has never before been built and an investigation has been made to determine the requirements for a Mars Sample Return (MSR) Sample Receiving Facility (SRF) from first principles based on a Biohazard Assessment Protocol (BAP) rather than the modification of an existing BSL-4 facility. This approach fully takes in to account cleanliness requirements to avoid sample contamination. This paper will present the results from the first part of an ESA funded study, which derived the top level functional requirements by reviewing published scientific literature from all expert domains i.e.; biocontainment, science curation, space technology, infrastructure and equipment. These functional requirements were then examined by invited attendees from all expert domains in a 2 day international workshop. From the results of the international workshop an existing Biohazard Assessment Protocol (BAP) was modified and a trade off was conducted to derive a preferred concept which allowed early indications of future technological direction of study. The results of the MSR SRF study by SEA (as well as the results of another parallel study) will be taken into account by ESA to define the requirements for a follow-on procurement action in the future. There will be a review of the results from both studies and an agreement on the requirements based on these parallel studies. Therefore, the views expressed herein should not be taken to reflect the official opinion of the European Space Agency.

  12. Liquid chromatography-tandem mass spectrometry determination of baclofen in various biological samples and application to a pharmacokinetic study.

    Science.gov (United States)

    Kim, Tae Hwan; Shin, Soyoung; Shin, Jeong Cheol; Choi, Jin Ho; Seo, Won Sik; Park, Gi-Young; Kwon, Dong Rak; Yoo, Sun Dong; Lee, Ah-Ram; Joo, Sang Hoon; Min, Byung Sun; Yoo, Won Young; Shin, Beom Soo

    2013-11-01

    Baclofen is a structural analogue of γ-aminobutyric acid (GABA) that has been used for the treatment of spasticity since 1977. This study describes a simple and sensitive LC/MS/MS assay for the quantification of baclofen in rat plasma, urine, as well as various tissue samples. The assay utilized a simple protein precipitation and achieved lower limit of quantification (LLOQ) of 0.25ng/mL for rat plasma and brain samples and 2ng/mL for rat urine, liver and kidney samples. The assay was validated to demonstrate the specificity, linearity, recovery, LLOQ, accuracy, precision, and stability by using matrix matched quality control samples. There is no endogenous or exogenous peaks interfering with the analytes and matrix effects were minimized by optimized separation condition. The assay was linear over a concentration range of 0.25-500ng/mL for rat plasma and brain tissue, and 2-5000ng/mL for rat urine, kidney and liver with correlation coefficients >0.999. The mean intra- and inter-day assay accuracies were 94.6-104.6 and 96.0-103.6%, respectively. The mean intra- and inter-day precisions were 5.71 and 5.70%, respectively. The developed assay was successfully applied to a pharmacokinetic study and examined urinary excretion and tissue distribution of baclofen in rats following intravenous and oral administration.

  13. Critical comparison of radiometric and mass spectrometric methods for the determination of radionuclides in environmental, biological and nuclear waste samples.

    Science.gov (United States)

    Hou, Xiaolin; Roos, Per

    2008-02-11

    The radiometric methods, alpha (alpha)-, beta (beta)-, gamma (gamma)-spectrometry, and mass spectrometric methods, inductively coupled plasma mass spectrometry, accelerator mass spectrometry, thermal ionization mass spectrometry, resonance ionization mass spectrometry, secondary ion mass spectrometry, and glow discharge mass spectrometry are reviewed for the determination of radionuclides. These methods are critically compared for the determination of long-lived radionuclides important for radiation protection, decommissioning of nuclear facilities, repository of nuclear waste, tracer application in the environmental and biological researches, these radionuclides include (3)H, (14)C, (36)Cl, (41)Ca, (59,63)Ni, (89,90)Sr, (99)Tc, (129)I, (135,137)Cs, (210)Pb, (226,228)Ra, (237)Np, (241)Am, and isotopes of thorium, uranium and plutonium. The application of on-line methods (flow injection/sequential injection) for separation of radionuclides and automated determination of radionuclides is also discussed.

  14. Towards tender X-rays with Zernike phase-contrast imaging of biological samples at 50 nm resolution.

    Science.gov (United States)

    Vartiainen, Ismo; Warmer, Martin; Goeries, Dennis; Herker, Eva; Reimer, Rudolph; David, Christian; Meents, Alke

    2014-07-01

    X-ray microscopy is a commonly used method especially in material science application, where the large penetration depth of X-rays is necessary for three-dimensional structural studies of thick specimens with high-Z elements. In this paper it is shown that full-field X-ray microscopy at 6.2 keV can be utilized for imaging of biological specimens with high resolution. A full-field Zernike phase-contrast microscope based on diffractive optics is used to study lipid droplet formation in hepatoma cells. It is shown that the contrast of the images is comparable with that of electron microscopy, and even better contrast at tender X-ray energies between 2.5 keV and 4 keV is expected.

  15. [Logistics of collection and transportation of biological samples and the organization of the central laboratory in the ELSA-Brasil].

    Science.gov (United States)

    Fedeli, Ligia G; Vidigal, Pedro G; Leite, Claudia Mendes; Castilhos, Cristina D; Pimentel, Robércia Anjos; Maniero, Viviane C; Mill, Jose Geraldo; Lotufo, Paulo A; Pereira, Alexandre C; Bensenor, Isabela M

    2013-06-01

    The ELSA (Estudo Longitudinal de Saúde do Adulto - Brazilian Longitudinal Study for Adult Health) is a multicenter cohort study which aims at the identification of risk factors associated with type 2 diabetes and cardiovascular diseases in the Brazilian population. The paper describes the strategies for the collection, processing, transportation, and quality control of blood and urine tests in the ELSA. The study decided to centralize the tests at one single laboratory. The processing of the samples was performed at the local laboratories, reducing the weight of the material to be transported, and diminishing the costs of transportation to the central laboratory at the Universidade de São Paulo Hospital. The study included tests for the evaluation of diabetes, insulin resistance, dyslipidemia, electrolyte abnormalities, thyroid hormones, uric acid, hepatic enzyme abnormalities, inflammation, and total blood cell count. In addition, leukocyte DNA, urine, plasma and serum samples were stored. The central laboratory performed approximately 375,000 tests.

  16. RNA expression microarrays (REMs), a high-throughput method to measure differences in gene expression in diverse biological samples

    OpenAIRE

    2004-01-01

    We have developed RNA expression microarrays (REMs), in which each spot on a glass support is composed of a population of cDNAs synthesized from a cell or tissue sample. We used simultaneous hybridization with test and reference (housekeeping) genes to calculate an expression ratio based on normalization with the endogenous reference gene. A test REM containing artificial mixtures of liver cDNA and dilutions of the bacterial LysA gene cDNA demonstrated the feasibility of detecting transcripts...

  17. Determination of noble metals in biological samples by electrothermal vaporization inductively coupled plasma mass spectrometry, following cloud point extraction

    Science.gov (United States)

    Andreia Mesquita da Silva, Márcia; Lúcia Azzolin Frescura, Vera; José Curtius, Adilson

    2001-10-01

    A simple separation procedure for noble metals based on cloud point extraction is proposed. The analyte ions in aqueous acidic solution, obtained by the acid digestion of the samples, were complexed with O, O-diethyl-dithiophosphate and Triton X-114 was added as a non-ionic surfactant. By increasing the temperature up to the cloud point, a phase separation occurs, resulting in an aqueous phase and a surfactant-rich phase containing most of the analytes that were complexed. The metals in the surfactant-rich phase were determined by electrothermal vaporization inductively coupled plasma mass spectrometry. The extraction conditions as well as the instrumental parameters were optimized. Enrichment factors ranging from 7 (Rh) to 60 (Pt) and limits of detection from 0.6 (Pt) to 3.0 ng l -1 (Rh) were obtained in the digested samples. The extraction was not efficient for Ir. Among the reference materials analyzed in this work, only one (SRM 2670, urine) presented recommended values for Au and Pt. Due to the non-availability of adequate CRMs, accuracy was assessed by spiking known analyte amounts to the acid digests. Recoveries close to 100% were observed for all the studied elements but Ru. Poor agreement between found and recommended values was observed for non-digested urine sample, probably due to the carrier effect of co-extracted residual matrix components. However, good agreement was reached after urine acid mineralization.

  18. Biological Sampling and Analysis in Sinclair and Dyes Inlets, Washington: Chemical Analyses for 2007 Puget Sound Biota Study

    Energy Technology Data Exchange (ETDEWEB)

    Brandenberger, Jill M.; Suslick, Carolynn R.; Johnston, Robert K.

    2008-10-09

    Evaluating spatial and temporal trends in contaminant residues in Puget Sound fish and macroinvertebrates are the objectives of the Puget Sound Ambient Monitoring Program (PSAMP). In a cooperative effort between the ENVironmental inVESTment group (ENVVEST) and Washington State Department of Fish and Wildlife, additional biota samples were collected during the 2007 PSAMP biota survey and analyzed for chemical residues and stable isotopes of carbon (δ13C) and nitrogen (δ15N). Approximately three specimens of each species collected from Sinclair Inlet, Georgia Basin, and reference locations in Puget Sound were selected for whole body chemical analysis. The muscle tissue of specimens selected for chemical analyses were also analyzed for δ13C and δ15N to provide information on relative trophic level and food sources. This data report summarizes the chemical residues for the 2007 PSAMP fish and macro-invertebrate samples. In addition, six Spiny Dogfish (Squalus acanthias) samples were necropsied to evaluate chemical residue of various parts of the fish (digestive tract, liver, embryo, muscle tissue), as well as, a weight proportional whole body composite (WBWC). Whole organisms were homogenized and analyzed for silver, arsenic, cadmium, chromium, copper, nickel, lead, zinc, mercury, 19 polychlorinated biphenyl (PCB) congeners, PCB homologues, percent moisture, percent lipids, δ13C, and δ15N.

  19. Application of direct solid sample analysis for the determination of chlorine in biological materials using electrothermal vaporization inductively coupled plasma mass spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Santos de Gois, Jefferson; Pereira, Éderson R. [Departamento de Química, Universidade Federal de Santa Catarina, 88040-970 Florianópolis, SC (Brazil); Welz, Bernhard [Departamento de Química, Universidade Federal de Santa Catarina, 88040-970 Florianópolis, SC (Brazil); INCT de Energia e Ambiente do CNPq (Brazil); Borges, Daniel L.G., E-mail: daniel.borges@ufsc.br [Departamento de Química, Universidade Federal de Santa Catarina, 88040-970 Florianópolis, SC (Brazil); INCT de Energia e Ambiente do CNPq (Brazil)

    2015-03-01

    This work describes a methodology developed to carry out Cl determination in biological materials using electrothermal vaporization inductively coupled plasma mass spectrometry and direct solid sample analysis. The solid samples were directly weighed into graphite ‘cups’ and inserted into the graphite furnace. The RF power and the carrier gas flow rate were optimized at 1300 W and 0.7 L min{sup −1}, respectively. Calibration could be carried out using aqueous standard solutions with pre-dried modifiers (Pd + Nd or Pd + Ca) or using solid certified reference materials with the same pre-dried modifiers or without the use of modifiers. The limit of quantification was determined as 5 μg g{sup −1} under optimized conditions and the Cl concentration was determined in five certified reference materials with certified concentrations for Cl, in addition to three certified reference materials, for which certified values for Cl were unavailable; in the latter case, the results were compared with those obtained using high-resolution continuum source molecular absorption spectrometry. Good agreement at a 95% statistical confidence level was achieved between determined and certified or reference values. - Highlights: • Direct determination of chlorine in solid biological materials is described for the first time using ICP-MS. • Calibration against aqueous standards is feasible. • The method is accurate and sensitive, regardless of the composition of the solid sample.

  20. Temperature-controlled micro-TLC: a versatile green chemistry and fast analytical tool for separation and preliminary screening of steroids fraction from biological and environmental samples.

    Science.gov (United States)

    Zarzycki, Paweł K; Slączka, Magdalena M; Zarzycka, Magdalena B; Bartoszuk, Małgorzata A; Włodarczyk, Elżbieta; Baran, Michał J

    2011-11-01

    This paper is a continuation of our previous research focusing on development of micro-TLC methodology under temperature-controlled conditions. The main goal of present paper is to demonstrate separation and detection capability of micro-TLC technique involving simple analytical protocols without multi-steps sample pre-purification. One of the advantages of planar chromatography over its column counterpart is that each TLC run can be performed using non-previously used stationary phase. Therefore, it is possible to fractionate or separate complex samples characterized by heavy biological matrix loading. In present studies components of interest, mainly steroids, were isolated from biological samples like fish bile using single pre-treatment steps involving direct organic liquid extraction and/or deproteinization by freeze-drying method. Low-molecular mass compounds with polarity ranging from estetrol to progesterone derived from the environmental samples (lake water, untreated and treated sewage waters) were concentrated using optimized solid-phase extraction (SPE). Specific bands patterns for samples derived from surface water of the Middle Pomerania in northern part of Poland can be easily observed on obtained micro-TLC chromatograms. This approach can be useful as simple and non-expensive complementary method for fast control and screening of treated sewage water discharged by the municipal wastewater treatment plants. Moreover, our experimental results show the potential of micro-TLC as an efficient tool for retention measurements of a wide range of steroids under reversed-phase (RP) chromatographic conditions. These data can be used for further optimalization of SPE or HPLC systems working under RP conditions. Furthermore, we also demonstrated that micro-TLC based analytical approach can be applied as an effective method for the internal standard (IS) substance search. Generally, described methodology can be applied for fast fractionation or screening of the

  1. Determination of androgens and progestogens in environmental and biological samples using fabric phase sorptive extraction coupled to ultra-high performance liquid chromatography tandem mass spectrometry.

    Science.gov (United States)

    Guedes-Alonso, Rayco; Ciofi, Lorenzo; Sosa-Ferrera, Zoraida; Santana-Rodríguez, José Juan; Bubba, Massimo Del; Kabir, Abuzar; Furton, Kenneth G

    2016-03-11

    Androgens and progestogens are two important groups of endocrine disrupting compounds (EDCs) which are implicated to produce severe detrimental impact over aquatic biota, even at very low concentrations of ngL(-1). For this reason, one of the major challenges to analytical chemists is the development of sensitive and selective extraction processes which allow the rapid and green determination of these emerging pollutants at low concentrations in environmental samples. Fabric phase sorptive extraction is a new, highly sensitive, efficient and solvent minimized technique which combine the advantages of sol-gel derived microextraction sorbents and the rich surface chemistry of cellulose fabric substrate. This process has several advantages such as minimum usage of organic solvents, short extraction times, small sample volumes and high analyte preconcentration factors. In this study, an extraction method based on sorptive fabric phase coupled to ultra-high-performance liquid chromatography tandem mass spectrometry detection (FPSE-UHPLC-MS/MS) has been developed for the determination of four progestogens and six androgens in environmental and biological samples. All the parameters involved in the extraction, such as sample volume, extraction and desorption times, desorption solvent volume and sample pH values have been optimized. The developed method provides satisfactory limits of detection (between 1.7 and 264ngL(-1)), good recoveries and low relative standard deviations (below 10% in tap and osmosis water and below 20% in wastewater and urine). Subsequently, the method was used to analyse tap water, wastewater treated with different processing technologies and urine samples. The concentrations of the detected hormones ranged from 28.3 to 227.3 ngL(-1) in water samples and from 1.1 to 3.7μgL(-1) in urine samples.

  2. 40 CFR 80.581 - What are the batch testing and sample retention requirements for motor vehicle diesel fuel, NRLM...

    Science.gov (United States)

    2010-07-01

    ... retention requirements for motor vehicle diesel fuel, NRLM diesel fuel, and ECA marine fuel? 80.581 Section...) REGULATION OF FUELS AND FUEL ADDITIVES Motor Vehicle Diesel Fuel; Nonroad, Locomotive, and Marine Diesel Fuel... requirements for motor vehicle diesel fuel, NRLM diesel fuel, and ECA marine fuel? (a) Beginning on June......

  3. Three-Dimensional X-ray Observation of Atmospheric Biological Samples by Linear-Array Scanning-Electron Generation X-ray Microscope System

    Science.gov (United States)

    Ogura, Toshihiko

    2011-01-01

    Recently, we developed a soft X-ray microscope called the scanning-electron generation X-ray microscope (SGXM), which consists of a simple X-ray detection system that detects X-rays emitted from the interaction between a scanning electron beam (EB) and the thin film of the sample mount. We present herein a three-dimensional (3D) X-ray detection system that is based on the SGXM technology and designed for studying atmospheric biological samples. This 3D X-ray detection system contains a linear X-ray photodiode (PD) array. The specimens are placed under a CuZn-coated Si3N4 thin film, which is attached to an atmospheric sample holder. Multiple tilt X-ray images of the samples are detected simultaneously by the linear array of X-ray PDs, and the 3D structure is calculated by a new 3D reconstruction method that uses a simulated-annealing algorithm. The resulting 3D models clearly reveal the inner structure of the bacterium. In addition, the proposed method can easily be used for diverse samples in a broad range of scientific fields. PMID:21731770

  4. Three-dimensional X-ray observation of atmospheric biological samples by linear-array scanning-electron generation X-ray microscope system.

    Science.gov (United States)

    Ogura, Toshihiko

    2011-01-01

    Recently, we developed a soft X-ray microscope called the scanning-electron generation X-ray microscope (SGXM), which consists of a simple X-ray detection system that detects X-rays emitted from the interaction between a scanning electron beam (EB) and the thin film of the sample mount. We present herein a three-dimensional (3D) X-ray detection system that is based on the SGXM technology and designed for studying atmospheric biological samples. This 3D X-ray detection system contains a linear X-ray photodiode (PD) array. The specimens are placed under a CuZn-coated Si₃N₄ thin film, which is attached to an atmospheric sample holder. Multiple tilt X-ray images of the samples are detected simultaneously by the linear array of X-ray PDs, and the 3D structure is calculated by a new 3D reconstruction method that uses a simulated-annealing algorithm. The resulting 3D models clearly reveal the inner structure of the bacterium. In addition, the proposed method can easily be used for diverse samples in a broad range of scientific fields.

  5. Three-dimensional X-ray observation of atmospheric biological samples by linear-array scanning-electron generation X-ray microscope system.

    Directory of Open Access Journals (Sweden)

    Toshihiko Ogura

    Full Text Available Recently, we developed a soft X-ray microscope called the scanning-electron generation X-ray microscope (SGXM, which consists of a simple X-ray detection system that detects X-rays emitted from the interaction between a scanning electron beam (EB and the thin film of the sample mount. We present herein a three-dimensional (3D X-ray detection system that is based on the SGXM technology and designed for studying atmospheric biological samples. This 3D X-ray detection system contains a linear X-ray photodiode (PD array. The specimens are placed under a CuZn-coated Si₃N₄ thin film, which is attached to an atmospheric sample holder. Multiple tilt X-ray images of the samples are detected simultaneously by the linear array of X-ray PDs, and the 3D structure is calculated by a new 3D reconstruction method that uses a simulated-annealing algorithm. The resulting 3D models clearly reveal the inner structure of the bacterium. In addition, the proposed method can easily be used for diverse samples in a broad range of scientific fields.

  6. A novel low-E field coil to minimize heating of biological samples in solid-state multinuclear NMR experiments

    Science.gov (United States)

    Dillmann, Baudouin; Elbayed, Karim; Zeiger, Heinz; Weingertner, Marie-Catherine; Piotto, Martial; Engelke, Frank

    2007-07-01

    A novel coil, called Z coil, is presented. Its function is to reduce the strong thermal effects produced by rf heating at high frequencies. The results obtained at 500 MHz in a 50 μl sample prove that the Z coil can cope with salt concentrations that are one order of magnitude higher than in traditional solenoidal coils. The evaluation of the rf field is performed by numerical analysis based on first principles and by carrying out rf field measurements. Reduction of rf heating is probed with a DMPC/DHPC membrane prepared in buffers of increasing salt concentrations. The intricate correlation that exists between the magnetic and electric field is presented. It is demonstrated that, in a multiply tuned traditional MAS coil, the rf electric field E1 cannot be reduced without altering the rf magnetic field. Since the detailed distribution differs when changing the coil geometry, a comparison involving the following three distinct designs is discussed: (1) a regular coil of 5.5 turns, (2) a variable pitch coil with the same number of turns, (3) the new Z coil structure. For each of these coils loaded with samples of different salt concentrations, the nutation fields obtained at a certain power level provide a basis to discuss the impact of the dielectric and conductive losses on the rf efficiency.

  7. Pre-Mission Input Requirements to Enable Successful Sample Collection by a Remote Field/EVA Team

    Science.gov (United States)

    Cohen, B. A.; Young, K. E.; Lim, D. S.

    2015-01-01

    This paper is intended to evaluate the sample collection process with respect to sample characterization and decision making. In some cases, it may be sufficient to know whether a given outcrop or hand sample is the same as or different from previous sampling localities or samples. In other cases, it may be important to have more in-depth characterization of the sample, such as basic composition, mineralogy, and petrology, in order to effectively identify the best sample. Contextual field observations, in situ/handheld analysis, and backroom evaluation may all play a role in understanding field lithologies and their importance for return. For example, whether a rock is a breccia or a clast-laden impact melt may be difficult based on a single sample, but becomes clear as exploration of a field site puts it into context. The FINESSE (Field Investigations to Enable Solar System Science and Exploration) team is a new activity focused on a science and exploration field based research program aimed at generating strategic knowledge in preparation for the human and robotic exploration of the Moon, near-Earth asteroids (NEAs) and Phobos and Deimos. We used the FINESSE field excursion to the West Clearwater Lake Impact structure (WCIS) as an opportunity to test factors related to sampling decisions. In contract to other technology-driven NASA analog studies, The FINESSE WCIS activity is science-focused, and moreover, is sampling-focused, with the explicit intent to return the best samples for geochronology studies in the laboratory. This specific objective effectively reduces the number of variables in the goals of the field test and enables a more controlled investigation of the role of the crewmember in selecting samples. We formulated one hypothesis to test: that providing details regarding the analytical fate of the samples (e.g. geochronology, XRF/XRD, etc.) to the crew prior to their traverse will result in samples that are more likely to meet specific analytical

  8. Efficient one-pot synthesis of hydrophilic and fluorescent molecularly imprinted polymer nanoparticles for direct drug quantification in real biological samples.

    Science.gov (United States)

    Niu, Hui; Yang, Yaqiong; Zhang, Huiqi

    2015-12-15

    Efficient one-pot synthesis of hydrophilic and fluorescent molecularly imprinted polymer (MIP) nanoparticles and their application as optical chemosensor for direct drug quantification in real, undiluted biological samples are described. The general principle was demonstrated by preparing tetracycline (Tc, a broad-spectrum antibiotic)-imprinted fluorescent polymer nanoparticles bearing hydrophilic polymer brushes via poly(2-hydroxyethyl methacrylate) (PHEMA) macromolecular chain transfer agent-mediated reversible addition-fragmentation chain transfer (RAFT) precipitation polymerization in the presence of a fluorescent monomer. The introduction of hydrophilic PHEMA brushes and fluorescence labeling onto/into the MIP nanoparticles proved to not only significantly improve their surface hydrophilicity and lead to their obvious specific binding and high selectivity toward Tc in the undiluted bovine serum, but also impart them with strong fluorescent properties. In particular, significant fluorescence quenching was observed upon their binding with Tc in such complex biological milieu, which makes these Tc-MIP nanoparticles useful optical chemosensor with a detection limit of 0.26 μM. Furthermore, such advanced functional MIP nanoparticles-based chemosensor was also successfully utilized for the direct, sensitive, and accurate determination of Tc in another biological medium (i.e., the undiluted pig serum) with average recoveries ranging from 98% to 102%, even in the presence of several interfering drugs.

  9. HIV among injecting drug users: current epidemiology, biologic markers, respondent-driven sampling, and supervised-injection facilities

    Science.gov (United States)

    Des Jarlais, Don C.; Arasteh, Kamyar; Semaan, Salaam; Wood, Evan

    2017-01-01

    Purpose of review To describe recent research done primarily during the past 12 months (i.e., primarily in 2008) on the epidemiology of HIV infection among injecting drug users (IDUs). Recent findings Major research developments include a global assessment of HIV infection among IDUs and evidence of a transition from epidemics concentrated among IDUs to generalized, heterosexual epidemics in eastern Europe and Asia. Intervention research also includes several studies of supervised-injecting facilities. Methodological research includes respondent-driven sampling and the use of hepatitis C virus and herpes simplex virus-2 as biomarkers for injecting and sexual risk. Summary There have been important advances in research during the past year, but HIV infection continues to spread rapidly across many areas of the world among IDUs and their nondrug-using sex partners. PMID:19532069

  10. Visualization in simulation tools: requirements and a tool specification to support the teaching of dynamic biological processes.

    Science.gov (United States)

    Jørgensen, Katarina M; Haddow, Pauline C

    2011-08-01

    Simulation tools are playing an increasingly important role behind advances in the field of systems biology. However, the current generation of biological science students has either little or no experience with such tools. As such, this educational glitch is limiting both the potential use of such tools as well as the potential for tighter cooperation between the designers and users. Although some simulation tool producers encourage their use in teaching, little attempt has hitherto been made to analyze and discuss their suitability as an educational tool for noncomputing science students. In general, today's simulation tools assume that the user has a stronger mathematical and computing background than that which is found in most biological science curricula, thus making the introduction of such tools a considerable pedagogical challenge. This paper provides an evaluation of the pedagogical attributes of existing simulation tools for cell signal transduction based on Cognitive Load theory. Further, design recommendations for an improved educational simulation tool are provided. The study is based on simulation tools for cell signal transduction. However, the discussions are relevant to a broader biological simulation tool set.

  11. Uncertainty in biological monitoring: a framework for data collection and analysis to account for multiple sources of sampling bias

    Science.gov (United States)

    Ruiz-Gutierrez, Viviana; Hooten, Melvin B.; Campbell Grant, Evan H.

    2016-01-01

    Biological monitoring programmes are increasingly relying upon large volumes of citizen-science data to improve the scope and spatial coverage of information, challenging the scientific community to develop design and model-based approaches to improve inference.Recent statistical models in ecology have been developed to accommodate false-negative errors, although current work points to false-positive errors as equally important sources of bias. This is of particular concern for the success of any monitoring programme given that rates as small as 3% could lead to the overestimation of the occurrence of rare events by as much as 50%, and even small false-positive rates can severely bias estimates of occurrence dynamics.We present an integrated, computationally efficient Bayesian hierarchical model to correct for false-positive and false-negative errors in detection/non-detection data. Our model combines independent, auxiliary data sources with field observations to improve the estimation of false-positive rates, when a subset of field observations cannot be validated a posteriori or assumed as perfect. We evaluated the performance of the model across a range of occurrence rates, false-positive and false-negative errors, and quantity of auxiliary data.The model performed well under all simulated scenarios, and we were able to identify critical auxiliary data characteristics which resulted in improved inference. We applied our false-positive model to a large-scale, citizen-science monitoring programme for anurans in the north-eastern United States, using auxiliary data from an experiment designed to estimate false-positive error rates. Not correcting for false-positive rates resulted in biased estimates of occupancy in 4 of the 10 anuran species we analysed, leading to an overestimation of the average number of occupied survey routes by as much as 70%.The framework we present for data collection and analysis is able to efficiently provide reliable inference for

  12. Two to five repeated measurements per patient reduced the required sample size considerably in a randomized clinical trial for patients with inflammatory rheumatic diseases

    OpenAIRE

    Smedslund Geir; Zangi Heidi Andersen; Mowinckel Petter; Hagen Kåre Birger

    2013-01-01

    Abstract Background Patient reported outcomes are accepted as important outcome measures in rheumatology. The fluctuating symptoms in patients with rheumatic diseases have serious implications for sample size in clinical trials. We estimated the effects of measuring the outcome 1-5 times on the sample size required in a two-armed trial. Findings In a randomized controlled trial that evaluated the effects of a mindfulness-based group intervention for patients with inflammatory arthritis (n=71)...

  13. Optimization of a validated stability-indicating RP-LC method for the determination of fulvestrant from polymeric based nanoparticle systems, drugs and biological samples.

    Science.gov (United States)

    Gumustas, Mehmet; Sengel-Turk, Ceyda Tuba; Hascicek, Canan; Ozkan, Sibel A

    2014-10-01

    Fulvestrant is used for the treatment of hormone receptor-positive metastatic breast cancer in postmenopausal women with disease progression following anti-estrogen therapy. Several reversed-phase columns with variable silica materials, diameters, lengths, etc., were tested for the optimization study. A good chromatographic separation was achieved using a Waters X-Terra RP(18) column (250 × 4.6 mm i.d. × 5 µm) and a mobile phase, consisting of a mixture of acetonitrile-water (65:35; v/v) containing phosphoric acid (0.1%). The separation was carried out 40 °C with detection at 215 nm.The calibration curves were linear over the concentration range between 1.0-300 and 1.0-200 µg/mL for standard solutions and biological media, respectively. The proposed method is accurate and reproducible. Forced degradation studies were also realized. This fully validated method allows the direct determination of fulvestrant in dosage form and biological samples. The average recovery of the added fulvestrant amount in the samples was between 98.22 and 104.03%. The proposed method was also applied for the determination of fulvestrant from the polymeric-based nanoparticle systems. No interference from using polymers and other excipients was observed in in vitro drug release studies. Therefore an incorporation efficiency of fulvestrant-loaded nanoparticle could be determined accurately and specifically.

  14. A sensitive single-enzyme assay system using the non-ribosomal peptide synthetase BpsA for measurement of L-glutamine in biological samples

    Science.gov (United States)

    Brown, Alistair S.; Robins, Katherine J.; Ackerley, David F.

    2017-01-01

    The ability to rapidly, economically and accurately measure L-glutamine concentrations in biological samples is important for many areas of research, medicine or industry, however there is room for improvement on existing methods. We describe here how the enzyme BpsA, a single-module non-ribosomal peptide synthetase able to convert L-glutamine into the blue pigment indigoidine, can be used to accurately measure L-glutamine in biological samples. Although indigoidine has low solubility in aqueous solutions, meaning direct measurements of indigoidine synthesis do not reliably yield linear standard curves, we demonstrate that resolubilisation of the reaction end-products in DMSO overcomes this issue and that spontaneous reduction to colourless leuco-indigoidine occurs too slowly to interfere with assay accuracy. Our protocol is amenable to a 96-well microtitre format and can be used to measure L-glutamine in common bacterial and mammalian culture media, urine, and deproteinated plasma. We show that active BpsA can be prepared in high yield by expressing it in the apo-form to avoid the toxicity of indigoidine to Escherichia coli host cells, then activating it to the holo-form in cell lysates prior to purification; and that BpsA has a lengthy shelf-life, retaining >95% activity when stored at either −20 °C or 4 °C for 24 weeks. PMID:28139746

  15. Mercapto-ordered carbohydrate-derived porous carbon electrode as a novel electrochemical sensor for simple and sensitive ultra-trace detection of omeprazole in biological samples

    Energy Technology Data Exchange (ETDEWEB)

    Kalate Bojdi, Majid [Department of Chemistry, Faculty of Science, Shahid Beheshti University, Tehran 1983963113 (Iran, Islamic Republic of); Faculty of Chemistry, Kharazmi (Tarbiat Moallem) University, Tehran (Iran, Islamic Republic of); Behbahani, Mohammad [Department of Chemistry, Faculty of Science, Shahid Beheshti University, Tehran 1983963113 (Iran, Islamic Republic of); Mashhadizadeh, Mohammad Hosein [Faculty of Chemistry, Kharazmi (Tarbiat Moallem) University, Tehran (Iran, Islamic Republic of); Bagheri, Akbar [Department of Chemistry, Faculty of Science, Shahid Beheshti University, Tehran 1983963113 (Iran, Islamic Republic of); Hosseiny Davarani, Saied Saeed, E-mail: ss-hosseiny@sbu.ac.ir [Department of Chemistry, Faculty of Science, Shahid Beheshti University, Tehran 1983963113 (Iran, Islamic Republic of); Farahani, Ali [Department of Chemistry, Faculty of Science, Shahid Beheshti University, Tehran 1983963113 (Iran, Islamic Republic of)

    2015-03-01

    We are introducing mercapto-mesoporous carbon modified carbon paste electrode (mercapto-MP-C-CPE) as a new sensor for trace determination of omeprazole (OM) in biological samples. The synthesized modifier was characterized by thermogravimetry analysis (TGA), differential thermal analysis (DTA), transmission electron microscopy (TEM), Fourier transform infrared spectrometry (FT-IR), X-ray diffraction (XRD), elemental analysis (CHN) and N{sub 2} adsorption surface area measurement (BET). The electrochemical response characteristic of the modified-CPE toward OM was investigated by cyclic and differential pulse voltammetry (CV and DPV). The proposed sensor displayed a good electrooxidation response to the OM, its linear range is 0.25 nM to 25 μM with a detection limit of 0.04 nM under the optimized conditions. The prepared modified electrode shows several advantages such as high sensitivity, long-time stability, wide linear range, ease of preparation and regeneration of the electrode surface by simple polishing and excellent reproducibility. - Highlights: • A modified nanoporous carbon as a novel sensor • High stability and good repeatability and reproducibility by the prepared sensor • Trace determination of omeprazole • Biological and pharmaceutical samples.

  16. Sequential cloud point extraction of trace elements from biological samples and determination by inductively coupled plasma mass spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Gine, Maria Fernanda; Patreze, Aparecida F.; Silva, Edson L. [Centro de Energia Nuclear na Agricultura (CENA-USP), Piracicaba, SP (Brazil)]. E-mail: mfgine@cena.usp.br; Sarkis, Jorge E.S.; Kakazu, Mauricio H. [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)

    2008-07-01

    A two-step sequential cloud point extraction (CPE) of trace elements from small sample volumes of human serum, animal blood, and food diet is proposed to gain analytical information in the analysis by inductively coupled plasma mass spectrometry. The first CPE was attained by adding O,O-diethyldithiophosphate, the non ionic surfactant Triton{sup R} X-114 followed by heating at 40 deg C, centrifugation and cooling at 0 deg C. The resulting surfactant-rich phase was separated to determine Cd, Pb and Cu by isotope dilution. Isotope ratio measurements presented RSD < 0.7%. The residual surfactant-poor phase solution had the pH adjusted in the range 4 to 5 before the chelating reagent, 4-(2-pyridylazo) resorcinol plus surfactant Triton{sup R} X-114 were added followed by the sequence to attain the CPE. Co and Ni were quantified in the second extracted surfactant-rich phases by standard additions method with RSD < 2%. Recoveries from 85 to 96% were obtained for all elements. Analyzing reference materials with certified and recommended values assessed accuracy. (author)

  17. A disposable screen-printed silver strip sensor for single drop analysis of halide in biological samples.

    Science.gov (United States)

    Chiu, Mei-Hsin; Cheng, Wan-Ling; Muthuraman, Govindan; Hsu, Cheng-Teng; Chung, Hsieh-Hsun; Zen, Jyh-Myng

    2009-06-15

    A screen-printed silver strip with three-electrode configuration of Ag-working, Ag-counter and Ag/Ag(x)O reference electrodes was developed for simultaneous determination of chloride, bromide and iodide in aqueous solutions. It was fabricated simply by screen-printing silver ink onto a polypropylene (PP) base. The in-situ prepared Ag/Ag(x)O reference electrode can avoid the leaching interference in chloride detection while using a conventional Ag/AgCl reference electrode. A single drop of analyte (50 microl) is enough to determine iodide, bromide and chloride by measuring the well-separated oxidation peak currents of respective silver halides. The calibration graph was linear from 10 microM to 20 mM for iodide and bromide and 100 microM to 20 mM for chloride and the detection limit (S/N=3) was 3.05 microM, 2.95 microM and 18.83 microM for iodide, bromide and chloride, respectively. The strip is designed to be disposable and as such manual polishing is not necessary. The proposed sensor is not only simple to manufacture and easy to operate but also fast and precise with little detection volume. It is successfully applied to the determination of halide ions in real samples.

  18. Determination of thallium at ultra-trace levels in water and biological samples using solid phase spectrophotometry.

    Science.gov (United States)

    Amin, Alaa S; El-Sharjawy, Abdel-Azeem M; Kassem, Mohammed A

    2013-06-01

    A new simple, very sensitive, selective and accurate procedure for the determination of trace amounts of thallium(III) by solid-phase spectrophotometry (SPS) has been developed. The procedure is based on fixation of Tl(III) as quinalizarin ion associate on a styrene-divinylbenzene anion-exchange resin. The absorbance of resin sorbed Tl(III) ion associate is measured directly at 636 and 830 nm. Thallium(I) was determined by difference measurements after oxidation of Tl(I) to Tl(III) with bromine. Calibration is linear over the range 0.5-12.0 μg L(-1) of Tl(III) with relative standard deviation (RSD) of 1.40% (n=10). The detection and quantification limits are 150 and 495 ng L(-1) using 0.6 g of the exchanger. The molar absorptivity and Sandell sensitivity are also calculated and found to be 1.31×10(7) L mol(-1)cm(-1) and 0.00156 ng cm(-2), respectively. The proposed procedure has been successfully applied to determine thallium in water, urine and serum samples.

  19. Determination of Iodate in Food, Environmental, and Biological Samples after Solid-Phase Extraction with Ni-Al-Zr Ternary Layered Double Hydroxide as a Nanosorbent

    Directory of Open Access Journals (Sweden)

    Hossein Abdolmohammad-Zadeh

    2012-01-01

    Full Text Available Nanostructured nickel-aluminum-zirconium ternary layered double hydroxide was successfully applied as a solid-phase extraction sorbent for the separation and pre-concentration of trace levels of iodate in food, environmental and biological samples. An indirect method was used for monitoring of the extracted iodate ions. The method is based on the reaction of the iodate with iodide in acidic solution to produce iodine, which can be spectrophotometrically monitored at 352 nm. The absorbance is directly proportional to the concentration of iodate in the sample. The effect of several parameters such as pH, sample flow rate, amount of nanosorbent, elution conditions, sample volume, and coexisting ions on the recovery was investigated. In the optimum experimental conditions, the limit of detection (3s and enrichment factor were 0.12 μg mL−1 and 20, respectively. The calibration graph using the preconcentration system was linear in the range of 0.2–2.8 μg mL−1 with a correlation coefficient of 0.998. In order to validate the presented method, a certified reference material, NIST SRM 1549, was also analyzed.

  20. Sample size requirements for estimating effective dose from computed tomography using solid-state metal-oxide-semiconductor field-effect transistor dosimetry

    Science.gov (United States)

    Trattner, Sigal; Cheng, Bin; Pieniazek, Radoslaw L.; Hoffmann, Udo; Douglas, Pamela S.; Einstein, Andrew J.

    2014-01-01

    Purpose: Effective dose (ED) is a widely used metric for comparing ionizing radiation burden between different imaging modalities, scanners, and scan protocols. In computed tomography (CT), ED can be estimated by performing scans on an anthropomorphic phantom in which metal-oxide-semiconductor field-effect transistor (MOSFET) solid-state dosimeters have been placed to enable organ dose measurements. Here a statistical framework is established to determine the sample size (number of scans) needed for estimating ED to a desired precision and confidence, for a particular scanner and scan protocol, subject to practical limitations. Methods: The statistical scheme involves solving equations which minimize the sample size required for estimating ED to desired precision and confidence. It is subject to a constrained variation of the estimated ED and solved using the Lagrange multiplier method. The scheme incorporates measurement variation introduced both by MOSFET calibration, and by variation in MOSFET readings between repeated CT scans. Sample size requirements are illustrated on cardiac, chest, and abdomen–pelvis CT scans performed on a 320-row scanner and chest CT performed on a 16-row scanner. Results: Sample sizes for estimating ED vary considerably between scanners and protocols. Sample size increases as the required precision or confidence is higher and also as the anticipated ED is lower. For example, for a helical chest protocol, for 95% confidence and 5% precision for the ED, 30 measurements are required on the 320-row scanner and 11 on the 16-row scanner when the anticipated ED is 4 mSv; these sample sizes are 5 and 2, respectively, when the anticipated ED is 10 mSv. Conclusions: Applying the suggested scheme, it was found that even at modest sample sizes, it is feasible to estimate ED with high precision and a high degree of confidence. As CT technology develops enabling ED to be lowered, more MOSFET measurements are needed to estimate ED with the same

  1. Two to five repeated measurements per patient reduced the required sample size considerably in a randomized clinical trial for patients with inflammatory rheumatic diseases

    Directory of Open Access Journals (Sweden)

    Smedslund Geir

    2013-02-01

    Full Text Available Abstract Background Patient reported outcomes are accepted as important outcome measures in rheumatology. The fluctuating symptoms in patients with rheumatic diseases have serious implications for sample size in clinical trials. We estimated the effects of measuring the outcome 1-5 times on the sample size required in a two-armed trial. Findings In a randomized controlled trial that evaluated the effects of a mindfulness-based group intervention for patients with inflammatory arthritis (n=71, the outcome variables Numerical Rating Scales (NRS (pain, fatigue, disease activity, self-care ability, and emotional wellbeing and General Health Questionnaire (GHQ-20 were measured five times before and after the intervention. For each variable we calculated the necessary sample sizes for obtaining 80% power (α=.05 for one up to five measurements. Two, three, and four measures reduced the required sample sizes by 15%, 21%, and 24%, respectively. With three (and five measures, the required sample size per group was reduced from 56 to 39 (32 for the GHQ-20, from 71 to 60 (55 for pain, 96 to 71 (73 for fatigue, 57 to 51 (48 for disease activity, 59 to 44 (45 for self-care, and 47 to 37 (33 for emotional wellbeing. Conclusions Measuring the outcomes five times rather than once reduced the necessary sample size by an average of 27%. When planning a study, researchers should carefully compare the advantages and disadvantages of increasing sample size versus employing three to five repeated measurements in order to obtain the required statistical power.

  2. 40 CFR 86.109-94 - Exhaust gas sampling system; Otto-cycle vehicles not requiring particulate emission measurements.

    Science.gov (United States)

    2010-07-01

    ...) Positive displacement pump. The Positive Displacement Pump-Constant Volume Sampler (PDP-CVS), Figure B94-1... volume is measured by counting the revolutions made by the calibrated positive displacement pump. The... and mixing assembly, heat exchanger, positive displacement pump, sampling systems (see Figure......

  3. Validation of limited sampling models (LSM) for estimating AUC in therapeutic drug monitoring - is a separate validation group required?

    NARCIS (Netherlands)

    Proost, J. H.

    2007-01-01

    Objective: Limited sampling models (LSM) for estimating AUC in therapeutic drug monitoring are usually validated in a separate group of patients, according to published guidelines. The aim of this study is to evaluate the validation of LSM by comparing independent validation with cross-validation us

  4. 40 CFR 80.583 - What alternative sampling and testing requirements apply to importers who transport motor vehicle...

    Science.gov (United States)

    2010-07-01

    ... requirements apply to importers who transport motor vehicle diesel fuel, NRLM diesel fuel, or ECA marine fuel by truck or rail car? 80.583 Section 80.583 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) REGULATION OF FUELS AND FUEL ADDITIVES Motor Vehicle Diesel...

  5. "PowerUp"!: A Tool for Calculating Minimum Detectable Effect Sizes and Minimum Required Sample Sizes for Experimental and Quasi-Experimental Design Studies

    Science.gov (United States)

    Dong, Nianbo; Maynard, Rebecca

    2013-01-01

    This paper and the accompanying tool are intended to complement existing supports for conducting power analysis tools by offering a tool based on the framework of Minimum Detectable Effect Sizes (MDES) formulae that can be used in determining sample size requirements and in estimating minimum detectable effect sizes for a range of individual- and…

  6. Evaluation of satellite collar sample size requirements for mitigation of low-level military jet disturbance of the George River caribou herd

    Directory of Open Access Journals (Sweden)

    Robert D. Otto

    2003-04-01

    Full Text Available Wildlife radio-telemetry and tracking projects often determine a priori required sample sizes by statistical means or default to the maximum number that can be maintained within a limited budget. After initiation of such projects, little attention is focussed on effective sample size requirements, resulting in lack of statistical power. The Department of National Defence operates a base in Labrador, Canada for low level jet fighter training activities, and maintain a sample of satellite collars on the George River caribou (Rangifer tarandus caribou herd of the region for spatial avoidance mitiga¬tion purposes. We analysed existing location data, in conjunction with knowledge of life history, to develop estimates of satellite collar sample sizes required to ensure adequate mitigation of GRCH. We chose three levels of probability in each of six annual caribou seasons. Estimated number of collars required ranged from 15 to 52, 23 to 68, and 36 to 184 for 50%, 75%, and 90% probability levels, respectively, depending on season. Estimates can be used to make more informed decisions about mitigation of GRCH, and, generally, our approach provides a means to adaptively assess radio collar sam¬ple sizes for ongoing studies.

  7. Dispersive solid-phase extraction as a simplified clean-up technique for biological sample extracts. Determination of polybrominated diphenyl ethers by gas chromatography-tandem mass spectrometry.

    Science.gov (United States)

    Fontana, Ariel R; Camargo, Alejandra; Martinez, Luis D; Altamirano, Jorgelina C

    2011-05-06

    Dispersive solid-phase extraction (DSPE) is proposed for the first time as a simplified, fast and low cost clean-up technique of biological sample extracts for polybrominated diphenyl ethers (PBDEs) determination. The combination of a traditional extraction technique, such as ultrasound-assisted leaching (USAL) with DSPE was successfully applied for sample preparation prior to gas chromatography-tandem mass spectrometry (GC-MS/MS) analysis. The analytes were first extracted from 1g homogenized sample in n-hexane:dichloromethane (8:2) by applying USAL technique and further cleaned-up using DSPE with 0.20 g C(18)-silica as sorbent material. Different solvent mixtures, sorbent type and amount, and lipid digestion procedures were evaluated in terms of clean-up and extraction efficiency. Under optimum conditions, the method detection limits (MDLs) for PBDEs, calculated as three times the signal-to-noise ratio (S/N) were within the range 9-44 pg g(-1) wet weight. The calibration graphs were linear within the concentration range of 53-500,000 pg g(-1), 66-500,000 pg g(-1), 89-500,000 pg g(-1) and 151-500,000 pg g(-1) for BDE-47, BDE-100, BDE-99 and BDE-153, respectively; and the coefficient of determination (r(2)) exceeded 0.9992 for all analytes. The proposed methodology was compared with a reference solid-phase extraction technique. The applicability of the methodology for the screening of PBDEs has been demonstrated by analyzing spiked and real samples of biological nature (fish, egg and chicken) with different lipid content as well as reference material (WELL-WMF-01). Recovery values ranged between 75% and 114% and the measured concentrations in certified material showed a reasonable agreement with the certified ones. BDE-47, BDE-100 and BDE-99 were quantified in three of the seven analyzed samples and the concentrations ranged between 91 and 140 pg g(-1). In addition, this work is the first description of PBDEs detected in fish of Argentinean environment.

  8. Multiplex Real-Time PCR Assay Using TaqMan Probes for the Identification of Trypanosoma cruzi DTUs in Biological and Clinical Samples

    Science.gov (United States)

    Cura, Carolina I.; Duffy, Tomas; Lucero, Raúl H.; Bisio, Margarita; Péneau, Julie; Jimenez-Coello, Matilde; Calabuig, Eva; Gimenez, María J.; Valencia Ayala, Edward; Kjos, Sonia A.; Santalla, José; Mahaney, Susan M.; Cayo, Nelly M.; Nagel, Claudia; Barcán, Laura; Málaga Machaca, Edith S.; Acosta Viana, Karla Y.; Brutus, Laurent; Ocampo, Susana B.; Aznar, Christine; Cuba Cuba, Cesar A.; Gürtler, Ricardo E.; Ramsey, Janine M.; Ribeiro, Isabela; VandeBerg, John L.; Yadon, Zaida E.; Osuna, Antonio; Schijman, Alejandro G.

    2015-01-01

    Background Trypanosoma cruzi has been classified into six Discrete Typing Units (DTUs), designated as TcI–TcVI. In order to effectively use this standardized nomenclature, a reproducible genotyping strategy is imperative. Several typing schemes have been developed with variable levels of complexity, selectivity and analytical sensitivity. Most of them can be only applied to cultured stocks. In this context, we aimed to develop a multiplex Real-Time PCR method to identify the six T. cruzi DTUs using TaqMan probes (MTq-PCR). Methods/Principal Findings The MTq-PCR has been evaluated in 39 cultured stocks and 307 biological samples from vectors, reservoirs and patients from different geographical regions and transmission cycles in comparison with a multi-locus conventional PCR algorithm. The MTq-PCR was inclusive for laboratory stocks and natural isolates and sensitive for direct typing of different biological samples from vectors, reservoirs and patients with acute, congenital infection or Chagas reactivation. The first round SL-IR MTq-PCR detected 1 fg DNA/reaction tube of TcI, TcII and TcIII and 1 pg DNA/reaction tube of TcIV, TcV and TcVI reference strains. The MTq-PCR was able to characterize DTUs in 83% of triatomine and 96% of reservoir samples that had been typed by conventional PCR methods. Regarding clinical samples, 100% of those derived from acute infected patients, 62.5% from congenitally infected children and 50% from patients with clinical reactivation could be genotyped. Sensitivity for direct typing of blood samples from chronic Chagas disease patients (32.8% from asymptomatic and 22.2% from symptomatic patients) and mixed infections was lower than that of the conventional PCR algorithm. Conclusions/Significance Typing is resolved after a single or a second round of Real-Time PCR, depending on the DTU. This format reduces carryover contamination and is amenable to quantification, automation and kit production. PMID:25993316

  9. Reprint of: Application of micro-thin-layer chromatography as a simple fractionation tool for fast screening of raw extracts derived from complex biological, pharmaceutical and environmental samples

    Energy Technology Data Exchange (ETDEWEB)

    Zarzycki, Pawel K., E-mail: pawel_k_z@hotmail.com [Section of Toxicology and Bioanalytics, Department of Civil and Environmental Engineering, Koszalin University of Technology, Sniadeckich 2, 75-453 Koszalin (Poland); Slaczka, Magdalena M.; Zarzycka, Magdalena B.; Wlodarczyk, Elzbieta; Baran, Michal J. [Section of Toxicology and Bioanalytics, Department of Civil and Environmental Engineering, Koszalin University of Technology, Sniadeckich 2, 75-453 Koszalin (Poland)

    2012-02-24

    The main goal of present paper is to demonstrate the separation and detection capability of micro-TLC technique involving simple one step liquid extraction protocols of complex materials without multi-steps sample pre-purification. In the present studies target components (cyanobacteria pigments, lipids and fullerenes) were isolated from heavy loading complex matrices including spirulina dried cells, birds' feathers and fatty oils as well as soot samples derived from biomass fuel and fossils-fired home heating systems. In each case isocratic separation protocol involving less that 1 mL of one component or binary mixture mobile phases can be completed within time of 5-8 min. Sensitive detection of components of interest was performed via fluorescence or staining techniques using iodine or phosphomolybdic acid. Described methodology can be applied for fast fractionation or screening of whole range of target substances as well as chemo-taxonomic studies and fingerprinting of complex mixtures, which are present in raw biological or environmental samples.

  10. Application of micro-thin-layer chromatography as a simple fractionation tool for fast screening of raw extracts derived from complex biological, pharmaceutical and environmental samples

    Energy Technology Data Exchange (ETDEWEB)

    Zarzycki, Pawel K., E-mail: pawel_k_z@hotmail.com [Section of Toxicology and Bioanalytics, Department of Civil and Environmental Engineering, Koszalin University of Technology, Sniadeckich 2, 75-453 Koszalin (Poland); Slaczka, Magdalena M.; Zarzycka, Magdalena B.; Wlodarczyk, Elzbieta; Baran, Michal J. [Section of Toxicology and Bioanalytics, Department of Civil and Environmental Engineering, Koszalin University of Technology, Sniadeckich 2, 75-453 Koszalin (Poland)

    2011-03-04

    The main goal of present paper is to demonstrate the separation and detection capability of micro-TLC technique involving simple one step liquid extraction protocols of complex materials without multi-steps sample pre-purification. In the present studies target components (cyanobacteria pigments, lipids and fullerenes) were isolated from heavy loading complex matrices including spirulina dried cells, birds' feathers and fatty oils as well as soot samples derived from biomass fuel and fossils-fired home heating systems. In each case isocratic separation protocol involving less that 1 mL of one component or binary mixture mobile phases can be completed within time of 5-8 min. Sensitive detection of components of interest was performed via fluorescence or staining techniques using iodine or phosphomolybdic acid. Described methodology can be applied for fast fractionation or screening of whole range of target substances as well as chemo-taxonomic studies and fingerprinting of complex mixtures, which are present in raw biological or environmental samples.

  11. Chemiluminescence determination of moxifloxacin in pharmaceutical and biological samples based on its enhancing effect of the luminol-ferricyanide system using a microfluidic chip.

    Science.gov (United States)

    Suh, Yeoun Suk; Kamruzzaman, Mohammad; Alam, Al-Mahmnur; Lee, Sang Hak; Kim, Young Ho; Kim, Gyu-Man; Dang, Trung Dung

    2014-05-01

    A sensitive determination of a synthetic fluoroquinolone antibacterial agent, moxifloxacin (MOX), by an enhanced chemiluminescence (CL) method using a microfluidic chip is described. The microfluidic chip was fabricated by a soft-lithographic procedure using polydimethyl siloxane (PDMS). The fabricated PDMS microfluidic chip had three-inlet microchannels for introducing the sample, chemiluminescent reagent and oxidant, and a 500 µm wide, 250 µm deep and 82 mm long microchannel. An enhanced CL system, luminol-ferricyanide, was adopted to analyze the MOX concentration in a sample solution. CL light was emitted continuously after mixing luminol and ferricyanide in the presence of MOX on the PDMS microfluidic chip. The amount of MOX in the luminol-ferricyanide system influenced the intensity of the CL light. The linear range of MOX concentration was 0.14-55.0 ng/mL with a correlation coefficient of 0.9992. The limit of detection (LOD) and limit of quantification (LOQ) were 0.06 and 0.2 ng/mL respectively. The presented method afforded good reproducibility, with a relative standard deviation (RSD) of 1.05% for 10 ng/mL of MOX, and has been successfully applied for the determination of MOX in pharmaceutical and biological samples.

  12. Non-destructive automated sampling of mycotoxins in bulk food and feed - A new tool for required harmonization.

    Science.gov (United States)

    Spanjer, M; Stroka, J; Patel, S; Buechler, S; Pittet, A; Barel, S

    2001-06-01

    Mycotoxins contamination is highly non-uniformly distributed as is well recog-nized by the EC, by not only setting legal limits in a series of commodities, but also schedule a sampling plan that takes this heterogeneity into account. In practice however, it turns out that it is very difficult to carry out this sampling plan in a harmonised way. Applying the sampling plan to a container filled with pallets of bags (i.e. with nuts or coffee beans) varies from very laborious to almost impossible. The presented non-destructive automated method to sample bulk food could help to overcome these practical problems and to enforcing of EC directives. It is derived from a tested and approved technology for detection of illicit substances in security applications. It has capability to collect and iden-tify ultra trace contaminants, i.e. from a fingerprint of chemical substance in a bulk of goods, a cargo pallet load (~ 1000 kg) with boxes and commodities.The technology, patented for explosives detection, uses physical and chemistry processes for excitation and remote rapid enhanced release of contaminant residues, vapours and particulate, of the inner/outer surfaces of inspected bulk and collect them on selective probes. The process is automated, takes only 10 minutes, is non-destructive and the bulk itself remains unharmed. The system design is based on applicable international regulations for shipped cargo hand-ling and transportation by road, sea and air. After this process the pallet can be loaded on a truck, ship or plane. Analysis can be carried out before the cargo leaves the place of shipping. The potent application of this technology for myco-toxins detection, has been demonstrated by preliminary feasibility experiments. Aflatoxins were detected in pistachios and ochratoxin A in green coffee beans bulk. Both commodities were naturally contaminated, priory found and confirm-ed by common methods as used at routine inspections. Once the contaminants are extracted from a

  13. Development of garlic bioactive compounds analytical methodology based on liquid phase microextraction using response surface design. Implications for dual analysis: Cooked and biological fluids samples.

    Science.gov (United States)

    Ramirez, Daniela Andrea; Locatelli, Daniela Ana; Torres-Palazzolo, Carolina Andrea; Altamirano, Jorgelina Cecilia; Camargo, Alejandra Beatriz

    2017-01-15

    Organosulphur compounds (OSCs) present in garlic (Allium sativum L.) are responsible of several biological properties. Functional foods researches indicate the importance of quantifying these compounds in food matrices and biological fluids. For this purpose, this paper introduces a novel methodology based on dispersive liquid-liquid microextraction (DLLME) coupled to high performance liquid chromatography with ultraviolet detector (HPLC-UV) for the extraction and determination of organosulphur compounds in different matrices. The target analytes were allicin, (E)- and (Z)-ajoene, 2-vinyl-4H-1,2-dithiin (2-VD), diallyl sulphide (DAS) and diallyl disulphide (DADS). The microextraction technique was optimized using an experimental design, and the analytical performance was evaluated under optimum conditions. The desirability function presented an optimal value for 600μL of chloroform as extraction solvent using acetonitrile as dispersant. The method proved to be reliable, precise and accurate. It was successfully applied to determine OSCs in cooked garlic samples as well as blood plasma and digestive fluids.

  14. Solvent-dependent turn-on probe for dual monitoring of Ag{sup +} and Zn{sup 2+} in living biological samples

    Energy Technology Data Exchange (ETDEWEB)

    Yang, Zheng; She, Mengyao [Ministry of Education Key Laboratory of Synthetic and Natural Functional Molecule Chemistry, College of Chemistry & Materials Science, Northwest University, Xi’an, Shaanxi 710069 (China); Yin, Bing [Ministry of Education Key Laboratory of Synthetic and Natural Functional Molecule Chemistry, College of Chemistry & Materials Science, Northwest University, Xi’an, Shaanxi 710069 (China); College of Chemistry, Beijing Normal University, No. 19, XinJieKouWai St., HaiDian District, Beijing 100875 (China); Hao, Likai; Obst, Martin [Center for Applied Geoscience, Institute for Geoscience, Eberhard Karls University Tuebingen, Hoelderlinstr. 12, Tuebingen 72074 (Germany); Liu, Ping, E-mail: liuping@nwu.edu.cn [Ministry of Education Key Laboratory of Synthetic and Natural Functional Molecule Chemistry, College of Chemistry & Materials Science, Northwest University, Xi’an, Shaanxi 710069 (China); Li, Jianli, E-mail: lijianli@nwu.edu.cn [Ministry of Education Key Laboratory of Synthetic and Natural Functional Molecule Chemistry, College of Chemistry & Materials Science, Northwest University, Xi’an, Shaanxi 710069 (China)

    2015-04-08

    Highlights: • A solvent-dependent probe was presented for dual monitoring of Ag{sup +} and Zn{sup 2+}. • The probe exhibited special selectivity and sensitivity at physiological range. • The mechanism was investigated both experimentally and computationally. • The probe was highly suitable for mapping Ag{sup +} and Zn{sup 2+} in biological samples. - Abstract: A novel, solvent-dependent “off–on” probe with benzoylthiourea moiety as the functional receptor and fluorescein as the fluorophore was designed for monitoring of Ag{sup +} in EtOH–H{sub 2}O (2:8, v/v) solution and Zn{sup 2+} in CH{sub 3}CN–H{sub 2}O (2:8, v/v) solution at physiological range with sufficient selectivity and sensitivity. The Ag{sup +} promoted desulfurization of thiosemicarbazide functionality in formation of the 1,3,4-oxadiazole and the coordination of Zn{sup 2+} to the O atom and N atom of the spoirolactam moiety and the S atom of the benzoylthiourea moiety were investigated to be the power that promoted the fluorescent enhancement. This probe was tested highly suitable for mapping Ag{sup +} and Zn{sup 2+} in living human osteosarcoma MG-63 cells and microbial cell–EPS–mineral aggregates, thus, providing a wonderful candidate for tracking Ag{sup +} and Zn{sup 2+} in biological organisms and processes.

  15. LESM: a laser-driven sub-MeV electron source delivering ultra-high dose rate on thin biological samples

    Science.gov (United States)

    Labate, L.; Andreassi, M. G.; Baffigi, F.; Bizzarri, R.; Borghini, A.; Bussolino, G. C.; Fulgentini, L.; Ghetti, F.; Giulietti, A.; Köster, P.; Lamia, D.; Levato, T.; Oishi, Y.; Pulignani, S.; Russo, G.; Sgarbossa, A.; Gizzi, L. A.

    2016-07-01

    We present a laser-driven source of electron bunches with average energy 260~\\text{keV} and picosecond duration, which has been setup for radiobiological tests covering the previously untested sub-MeV energy range. Each bunch combines high charge with short duration and sub-millimeter range into a record instantaneous dose rate, as high as {{10}9}~\\text{Gy}~{{\\text{s}}-1} . The source can be operated at 10~\\text{Hz} and its average dose rate is 35~\\text{mGy}~{{\\text{s}}-1} . Both the high instantaneous dose rate and high level of relative biological effectiveness, attached to sub-MeV electrons, make this source very attractive for studies of ultrafast radiobiology on thin cell samples. The source reliability, in terms of shot-to-shot stability of features such as mean energy, bunch charge and transverse beam profile, is discussed, along with a dosimetric characterization. Finally, a few preliminary biological tests performed with this source are presented.

  16. Enhanced flow injection analysis for measurements of S-nitrosothiols species in biological samples using highly selective amperometric nitric oxide sensor

    Institute of Scientific and Technical Information of China (English)

    Chun Cui Huang; Hui Bo Shao

    2012-01-01

    A highly selective nitric oxide (NO) sensor is fabricated and applied to devise an enhanced flow injection analysis (FIA) system for S-nitrosothiols (RSNOs) measurement in biological samples.The NO sensor is prepared using a polytetrafluoroethylene (PTFE) gas-permeable membrane loaded with Teflon AF(R) solution,a copolymer of tetrafluoroethylene and 2,2-bis(trifluoroethylene)-4,5-difluoro-1,3-dioxole,to improve selectivity.This method is much simpler and possesses good performance over a wide range of RSNOs concentrations.Standard deviation for three parallel measurements of blood plasma is 4.0%.The use of the gas sensing configuration as the detector enhances selectivity of the FIA measurement vs.using less selective electrochemical detectors that do not use PTFE/Teflon type outer membranes.

  17. An improved analytical method for the determination of urea nitrogen isotopomers in biological samples utilizing continuous flow isotope ratio mass spectrometry.

    Science.gov (United States)

    Marini, Juan C; Attene-Ramos, Matias Sebastian

    2006-01-01

    Over the past few years numerous dual inlet isotope ratio mass spectrometry (IRMS) applications have been adapted to continuous flow systems which allow the automation of sample admission and a higher throughput. The isotopomer analysis of urea nitrogen by IRMS requires the offline conversion of urea into nitrogen gas before analysis. The oxidation of urea with LiOBr results in the monomolecular degradation of urea, which preserves the identity of the parent urea molecule, and has to be conducted under vacuum to prevent contamination with atmospheric nitrogen. We have developed an offline system of urea degradation utilizing disposable Exetainers, in which atmospheric nitrogen is displaced by helium. Recovery of urea nitrogen was linear within the range of the standards tested (0 to 420 microg nitrogen) and standard curves for 15N15N-urea standards showed high coefficients of determination (R2 > 0.9998). A small portion of urea degrades in a non-monomolecular fashion and has been shown to depend on the concentration of urea in the sample. Long-term storage of prepared samples showed a decline in 15N15N enrichment, suggesting air contamination. However, samples were stable for 24 h, which allows for the analysis of large sample batches. Interest in urea metabolism, particularly in ruminant species, has increased recently due to the environmental implications of urea and nitrogen excretion by farm animals. This novel analytical method will allow for accurate measurements and the rapid throughput needed in order to support these field studies.

  18. Recent applications on isotope ratio measurements by ICP-MS and LA-ICP-MS on biological samples and single particles

    Science.gov (United States)

    Becker, J. Sabine; Sela, Hagit; Dobrowolska, Justina; Zoriy, Miroslav; Becker, J. Susanne

    2008-02-01

    Inductively coupled plasma mass spectrometry (ICP-MS) and laser ablation ICP-MS (LA-ICP-MS) have proved themselves to be powerful and sensitive inorganic mass spectrometric techniques for analysing stable and radioactive isotopes in different application fields because of their high sensitivity, low detection limits, good accuracy and precision. New applications of ICP-MS focus on tracer experiments and the development of isotope dilution techniques together with nanoflow injections for the analysis of small volumes of biological samples. Today, LA-ICP-MS is the method of choice for direct determination of metals, e.g., on protein bands in gels after the gel electrophoresis of protein mixtures. Tracer experiments using highly enriched 65Cu were utilized in order to study the formation of metal-binding bovine serum proteins. A challenging task for LA-ICP-MS is its application as an imaging mass spectrometric technique for the production of isotope images (e.gE, from thin sections of brain tissues stained with neodymium). In this paper, we demonstrate the application of imaging mass spectrometry on single particles (zircon and uranium oxide). Single Precambrian zircon crystals from the Baltic Shield were investigated with respect to isotope ratios using LA-ICP-MS for age dating. The U-Pb age was determined from the isochrone with (1.48 ± 0.14) × 109 a. Using isotope ratio measurements on 10 nuclear uranium oxide single particles the 235U/238U isotope ratio was determined to be 0.032 ± 0.004. This paper describes recent developments and applications of isotope ratio measurements by ICP-MS and LA-ICP-MS on biological samples and single particles.

  19. Characterization of L-cysteine capped CdTe quantum dots and application to test Cu(II) deficiency in biological samples from critically ill patients

    Energy Technology Data Exchange (ETDEWEB)

    Sáez, Laura; Molina, Jorge; Florea, Daniela I.; Planells, Elena M. [Institute of Nutrition and Food Technology and Department of Physiology, Faculty of Pharmacy, Campus Cartuja, University of Granada, E-18071 Granada (Spain); Cabeza, M. Carmen [Department of Physical Chemistry, Faculty of Pharmacy, University of Granada, E-18071 Granada (Spain); Quintero, Bartolomé, E-mail: bqosso@ugr.es [Department of Physical Chemistry, Faculty of Pharmacy, University of Granada, E-18071 Granada (Spain)

    2013-06-27

    Graphical abstract: -- Highlights: •We examinate stability of L-cysteine capped CdTe QD. •Factors influence QD fluorescence response are controlled. •Application in copper deficiency analysis is made. •We report comparison with other techniques. -- Abstract: The catalytic activity of copper ion gives, from the physiological point of view, a central role in many biological processes. Variations in the composition and location of cellular copper have been addressed given their physiological and pathological consequences. In this paper L-cysteine capped CdTe quantum dots is used for the fluorimetric determination of Cu(II) in biological samples from healthy individuals and patients admitted to the Intensive Care Units (ICU). An acceptable homogeneity in the CdTe QDs size has been obtained with an average value of 3 nm. No significant alterations in the spectral properties were observed for 2 months when stored in vacutainers at 6 °C and a concentration of approximately 2 μM. Data from oxidative stress markers such superoxide dismutase, total antioxidant capacity and DNA damage can be correlated with a Cu(II) deficiency for the ICU patients as measured by flame-atomic absorption spectroscopy (FAAS) and inductively coupled plasma source mass spectrometry (ICP-MS). Aqueous solutions 0.3 μM of L-cysteine capped CdTe QDs in MOPS buffer (6 mM, pH 7.4) used at 21 °C in the range 15–60 min after preparation of the sample for the measurements of fluorescence gives contents in Cu(II) for erythrocytes in good agreement with those obtained in FAAS and ICP-MS but the comparative ease of use makes the fluorimetric technique more suitable than the other two techniques for routine analysis.

  20. Chromatographic and spectroscopic characterization of urolithins for their determination in biological samples after the intake of foods containing ellagitannins and ellagic acid.

    Science.gov (United States)

    García-Villalba, Rocío; Espín, Juan Carlos; Tomás-Barberán, Francisco A

    2016-01-08

    Ellagitannins and ellagic acid (EA) are metabolized by the gut microbiota to produce urolithins that could be responsible for the health effects attributed to ellagitannin-containing food products. Several urolithin aglycones could be present in fecal samples while glucuronide and sulphate conjugates are mainly found in plasma and urine. So far, the lack of available standards has made difficult their correct identification and quantification. In the present study, UV and MS spectra characteristics of urolithins and their phase II metabolites have been determined using different systems based on liquid chromatography (LC) coupled with diode-array or mass spectrometer detectors with different analyzers (triple quadrupole (QqQ) and quadrupole time-of-flight (QTOF)). Chromatographic separation was achieved on a reversed-phase Poroshell C18 column (3×100mm, 2.7μm). Elution order, characteristic UV spectra, and relative response factors (RRFs) with respect to their parental compound (EA) and the most common metabolite urolithin A (Uro-A) were determined. This contribution, along with the most important mass spectra characteristics (MRM transitions, qualifier/quantifier ratio, accurate mass and fragmentation pattern) will allow the determination of urolithin metabolites in different biological samples and their quantification even if not all metabolites are commercially available. The methods developed in the three systems have been fully validated in terms of linearity, sensitivity, precision, recovery, matrix effect, selectivity and stability. After that, they were successfully applied to complex biological matrices (urine, feces and plasma) from two human studies in which volunteers consumed ellagitannin-containing foods, such as walnuts and pomegranate extracts.

  1. Acrylamide-functionalized graphene micro-solid-phase extraction coupled to high-performance liquid chromatography for the online analysis of trace monoamine acidic metabolites in biological samples.

    Science.gov (United States)

    Yang, Xiaoting; Hu, Yufei; Li, Gongke; Zhang, Zhuomin

    2015-05-01

    Monoamine acidic metabolites in biological samples are essential biomarkers for the diagnosis of neurological disorders. In this work, acrylamide-functionalized graphene adsorbent was successfully synthesized by a chemical functionalization method and was packed in a homemade polyether ether ketone micro column as a micro-solid-phase extraction unit. This micro-solid-phase extraction unit was directly coupled to high-performance liquid chromatography to form an online system for the separation and analysis of three monoamine acidic metabolites including homovanillic acid, 5-hydroxyindole-3-acetic acid, and 3,4-dihydroxyphenylacetic acid in human urine and plasma. The online system showed high stability, permeability, and adsorption capacity toward target metabolites. The saturated extraction amount of this online system was 213.1, 107.0, and 153.4 ng for homovanillic acid, 5-hydroxyindole-3-acetic acid, and 3,4-dihydroxyphenylacetic acid, respectively. Excellent detection limits were achieved in the range of 0.08-0.25 μg/L with good linearity and reproducibility. It was interesting that three targets in urine and plasma could be actually quantified to be 0.94-3.93 μg/L in plasma and 7.15-19.38 μg/L in urine. Good recoveries were achieved as 84.8-101.4% for urine and 77.8-95.1% for plasma with the intra- and interday relative standard deviations less than 9.3 and 10.3%, respectively. This method shows great potential for online analysis of trace monoamine acidic metabolites in biological samples.

  2. A Simple Spectrophotometric Method for the Determination of Copper in Some Real, Environmental, Biological, Food and Soil Samples Using Salicylaldehyde Benzoyl Hydrazone

    Directory of Open Access Journals (Sweden)

    M. Jamaluddin Ahmed

    2012-06-01

    Full Text Available A very simple, ultra-sensitive, highly selective and non-extractive spectrophotometric method for the determination of trace amounts copper(II has been developed. Salicylaldehy debenzoyl hydrazone (SAL-BH has been proposed as a new analytical reagent for the direct non-extractive spectrophotometric determination of copper(II. SAL-BH reacts with copper in a slightly acidic (0.0001-0.005 M H2SO4 in 40% 1,4-dioxane media with copper(II to give a highly absorbent greenish yellow chelate with a molar ratio 1:1(CuII: SAL-BH The reaction is instantaneous and the maximum absorption was obtained at 404 nm and remains stable for 72 h. The average molar absorptivity and Sandell’s sensitivity were found to be 1.4×105 L mol-1 cm-1 and 5.0 ng cm-2 of copper(II, respectively. Linear calibration graphs were obtained for 0.01 – 18 mg L-1 of CuII. The detection limit and quantification limit of the reaction system were found to be 1 ng mL-1 and 10 µg L-1, respectively. A large excess of over 50 cations, anions and complexing agents (e.g., tartrate, oxalate, citrate, phosphate, thiocyanate etc. do not interfere in the determination. The method is highly selective for copper and was successfully used for the determination of copper in several standard reference materials (steels and alloys as well as in some environmental waters (portable and polluted, biological (human blood and urine, food and soil samples and solutions containing both copper(I and copper(II as well as some complex synthetic mixtures. The results of the proposed method for biological and food samples were comparable with AAS and were found to be in good agreement. The method has high precision and accuracy (s = ± 0.01 for 0.5 mg L-1.

  3. Modified ionic liquid cold-induced aggregation dispersive liquid-liquid microextraction combined with spectrofluorimetry for trace determination of ofloxacin in pharmaceutical and biological samples

    Science.gov (United States)

    Zeeb, M.; Ganjali, M.R.; Norouzi, P.

    2011-01-01

    Background and the purpose of the study Ofloxacin is a quinolone synthetic antibiotic, which acts against resistant mutants of bacteria by inhibiting DNA gyrase. This antibacterial agent is widely used in the treatment of respiratory tract, urinary tract and tissue-based infections, which are caused by Gram-positive and Gram-negative bacteria. In this work, an efficient modified ionic liquid cold-induced aggregation dispersive liquid-liquid microextraction (M-IL-CIA-DLLME) was combined with spectrofluorimetry for trace determination of ofloxacin in real samples. Methods In this microextraction method, hydrophobic 1-hexyl-3-methylimidazolium hexafluorophosphate ([Hmim] [PF6]) ionic liquid (IL) as a microextraction solvent was dispersed into a heated sample solution containing sodium hexafluorophosphate (NaPF6) (as a common ion) and the analyte of interest. Afterwards, the resultant solution was cooled in an ice-water bath and a cloudy condition was formed due to a considerable decrease of IL solubility. After centrifuging, the enriched phase was introduced to the spectrofluorimeter for the determination of ofloxacin. Results and major conclusion In this technique, the performance of the microextraction method was not influenced by variations in the ionic strength of the sample solution (up to 30% w/v). Furthermore, [Hmim][PF6] IL was chosen as a green microextraction phase and an alternative to traditional toxic organic solvents. Different parameters affecting the analytical performance were studied and optimized. At optimum conditions, a relatively broad linear dynamic range of 0.15-125 µg l-1 and a limit of detection (LOD) of 0.029 µg l-1 were obtained. The relative standard deviation (R.S.D.) obtained for the determination of five replicates of the 10 ml solution containing 50 µg l-1 ofloxacin was 2.7%. Finally, the combined methodology was successfully applied to ofloxacin determination in actual pharmaceutical formulations and biological samples. PMID

  4. Modified Ionic Liquid Cold-Induced Aggregation Dispersive Liquid-Liquid Microextraction Combined with Spectrofluorimetry for Trace Determination of Ofloxacin in Pharmaceutical and Biological Samples

    Directory of Open Access Journals (Sweden)

    P. Norouzi

    2011-12-01

    Full Text Available Background and the purpose of the study: Ofloxacin is a quinolone synthetic antibiotic, which acts against resistant mutants of bacteria by inhibiting DNA gyrase. This antibacterial agent is widely used in the treatment of respiratory tract, urinary tract and tissue-based infections, which are caused by Gram-positive and Gram-negative bacteria. In this work, an efficient modified ionic liquid cold-induced aggregation dispersive liquid-liquid microextraction (M-IL-CIA-DLLME was combined with spectrofluorimetry for trace determination of ofloxacin in real samples.Methods: In this microextraction method, hydrophobic 1-hexyl-3-methylimidazolium hexafluorophosphate ([Hmim] [PF6] ionic liquid (IL as a microextraction solvent was dispersed into a heated sample solution containing sodium hexafluorophosphate (NaPF6 (as a common ion and the analyte of interest. Afterwards, the resultant solution was cooled in an ice-water bath and a cloudy condition was formed due to a considerable decrease of IL solubility. After centrifuging, the enriched phase was introduced to the spectrofluorimeter for the determination of ofloxacin.Results and major conclusion: In this technique, the performance of the microextraction method was not influenced by variations in the ionic strength of the sample solution (up to 30% w/v. Furthermore, [Hmim][PF6] IL was chosen as a green microextraction phase and an alternative to traditional toxic organic solvents. Different parameters affecting the analytical performance were studied and optimized. At optimum conditions, a relatively broad linear dynamic range of 0.15-125 μg l-1 and a limit of detection (LOD of 0.029 μg l-1 were obtained. The relative standard deviation (R.S.D. obtained for the determination of five replicates of the 10 ml solution containing 50 μg l-1 ofloxacin was 2.7%. Finally, the combined methodology was successfully applied to ofloxacin determination in actual pharmaceutical formulations and biological samples.

  5. A novel biological activity of praziquantel requiring voltage-operated Ca2+ channel beta subunits: subversion of flatworm regenerative polarity.

    Directory of Open Access Journals (Sweden)

    Taisaku Nogi

    Full Text Available BACKGROUND: Approximately 200 million people worldwide harbour parasitic flatworm infections that cause schistosomiasis. A single drug-praziquantel (PZQ-has served as the mainstay pharmacotherapy for schistosome infections since the 1980s. However, the relevant in vivo target(s of praziquantel remain undefined. METHODS AND FINDINGS: Here, we provide fresh perspective on the molecular basis of praziquantel efficacy in vivo consequent to the discovery of a remarkable action of PZQ on regeneration in a species of free-living flatworm (Dugesia japonica. Specifically, PZQ caused a robust (100% penetrance and complete duplication of the entire anterior-posterior axis during flatworm regeneration to yield two-headed organisms with duplicated, integrated central nervous and organ systems. Exploiting this phenotype as a readout for proteins impacting praziquantel efficacy, we demonstrate that PZQ-evoked bipolarity was selectively ablated by in vivo RNAi of voltage-operated calcium channel (VOCC beta subunits, but not by knockdown of a VOCC alpha subunit. At higher doses of PZQ, knockdown of VOCC beta subunits also conferred resistance to PZQ in lethality assays. CONCLUSIONS: This study identifies a new biological activity of the antischistosomal drug praziquantel on regenerative polarity in a species of free-living flatworm. Ablation of the bipolar regenerative phenotype evoked by PZQ via in vivo RNAi of VOCC beta subunits provides the first genetic evidence implicating a molecular target crucial for in vivo PZQ activity and supports the 'VOCC hypothesis' of PZQ efficacy. Further, in terms of regenerative biology and Ca(2+ signaling, these data highlight a novel role for voltage-operated Ca(2+ entry in regulating in vivo stem cell differentiation and regenerative patterning.

  6. Preconcentration and Determination of Mefenamic Acid in Pharmaceutical and Biological Fluid Samples by Polymer-grafted Silica Gel Solid-phase Extraction Following High Performance Liquid Chromatography

    Science.gov (United States)

    Bagheri Sadeghi, Hayedeh; Panahi, Homayon Ahmad; Mahabadi, Mahsa; Moniri, Elham

    2015-01-01

    Mefenamic acid is a nonsteroidal anti-inflammatory drug (NSAID) that has analgesic, anti-infammatory and antipyretic actions. It is used to relieve mild to moderate pains. Solid-phase extraction of mefenamic acid by a polymer grafted to silica gel is reported. Poly allyl glycidyl ether/iminodiacetic acid-co-N, N-dimethylacrylamide was synthesized and grafted to silica gel and was used as an adsorbent for extraction of trace mefenamic acid in pharmaceutical and biological samples. Different factors affecting the extraction method were investigated and optimum conditions were obtained. The optimum pH value for sorption of mefenamic acid was 4.0. The sorption capacity of grafted adsorbent was 7.0 mg/g. The best eluent solvent was found to be trifluoroacetic acid-acetic acid in methanol with a recovery of 99.6%. The equilibrium adsorption data of mefenamic acid by grafted silica gel was analyzed by Langmuir model. The conformation of obtained data to Langmuir isotherm model reveals the homogeneous binding sites of grafted silica gel surface. Kinetic study of the mefenamic acid sorption by grafted silica gel indicates the good accessibility of the active sites in the grafted polymer. The sorption rate of the investigated mefenamic acid on the grafted silica gel was less than 5 min. This novel synthesized adsorbent can be successfully applied for the extraction of trace mefenamic acid in human plasma, urine and pharmaceutical samples. PMID:26330865

  7. Determination of trace aluminum in biological and water samples by cloud point extraction preconcentration and graphite furnace atomic absorption spectrometry detection

    Energy Technology Data Exchange (ETDEWEB)

    Sang Hongbo [Key Laboratory of Pesticide and Chemical Biology of Ministry of Education, College of Chemistry, Central China Normal University, Wuhan 430079 (China); Liang Pei [Key Laboratory of Pesticide and Chemical Biology of Ministry of Education, College of Chemistry, Central China Normal University, Wuhan 430079 (China)], E-mail: liangpei@mail.ccnu.edu.cn; Du Dan [Key Laboratory of Pesticide and Chemical Biology of Ministry of Education, College of Chemistry, Central China Normal University, Wuhan 430079 (China)

    2008-06-15

    A cloud point extraction (CPE) method for the preconcentration of trace aluminum prior to its determination by graphite furnace atomic absorption spectrometry (GFAAS) has been developed. The CPE method is based on the complex of Al(III) with 1-phenyl-3-methyl-4-benzoyl-5-pyrazolone (PMBP), and then entrapped in non-ionic surfactant Triton X-114. PMBP was used not only as chelating reagent in CPE preconcentration, but also as chemical modifier in GFAAS determination. The main factors affecting CPE efficiency, such as pH of sample solution, concentration of PMBP and Triton X-114, equilibration temperature and time, were investigated in detail. An enrichment factor of 37 was obtained for the preconcentration of Al(III) with 10 mL solution. Under the optimal conditions, the detection limit of this method for Al(III) is 0.09 ng mL{sup -1}, and the relative standard deviation is 4.7% at 10 ng mL{sup -1} Al(III) level (n = 7). The proposed method has been applied for determination of trace amount of aluminum in biological and water samples with satisfactory results.

  8. Determination of ultra trace amounts of bismuth in biological and water samples by electrothermal atomic absorption spectrometry (ET-AAS) after cloud point extraction

    Energy Technology Data Exchange (ETDEWEB)

    Shemirani, Farzaneh; Baghdadi, Majid; Ramezani, Majid; Jamali, Mohammad Reza

    2005-04-04

    A new approach for a cloud point extraction electrothermal atomic absorption spectrometric method was used for determining bismuth. The aqueous analyte was acidified with sulfuric acid (pH 3.0-3.5). Triton X-114 was added as a surfactant and dithizone was used as a complexing agent. After phase separation at 50 deg. C based on the cloud point separation of the mixture, the surfactant-rich phase was diluted using tetrahydrofuran (THF). Twenty microliters of the enriched solution and 10 {mu}l of 0.1% (w/v) Pd(NO{sub 3}){sub 2} as chemical modifier were dispersed into the graphite tube and the analyte determined by electrothermal atomic absorption spectrometry. After optimizing extraction conditions and instrumental parameters, a preconcentration factor of 196 was obtained for a sample of only 10 ml. The detection limit was 0.02 ng ml{sup -1} and the analytical curve was linear for the concentration range of 0.04-0.60 ng ml{sup -1}. Relative standard deviations were <5%. The method was successfully applied for the extraction and determination of bismuth in tap water and biological samples (urine and hair)

  9. A new cloud point extraction procedure for determination of inorganic antimony species in beverages and biological samples by flame atomic absorption spectrometry.

    Science.gov (United States)

    Altunay, Nail; Gürkan, Ramazan

    2015-05-15

    A new cloud-point extraction (CPE) for the determination of antimony species in biological and beverages samples has been established with flame atomic absorption spectrometry (FAAS). The method is based on the fact that formation of the competitive ion-pairing complex of Sb(III) and Sb(V) with Victoria Pure Blue BO (VPB(+)) at pH 10. The antimony species were individually detected by FAAS. Under the optimized conditions, the calibration range for Sb(V) is 1-250 μg L(-1) with a detection limit of 0.25 μg L(-1) and sensitive enhancement factor of 76.3 while the calibration range for Sb(III) is 10-400 μg L(-1) with a detection limit of 5.15 μg L(-1) and sensitive enhancement factor of 48.3. The precision as a relative standard deviation is in range of 0.24-2.35%. The method was successfully applied to the speciative determination of antimony species in the samples. The validation was verified by analysis of certified reference materials (CRMs).

  10. Determination of organotin compounds in biological samples using accelerated solvent extraction, sodium tetraethylborate ethylation, and multicapillary gas chromatography-flame photometric detection.

    Science.gov (United States)

    Wasik, Andrzej; Ciesielski, Tomasz

    2004-03-01

    A method has been developed for species-selective analysis of organotin compounds in solid, biological samples. The procedure is based on accelerated solvent extraction (ASE) of analytes and includes extraction of the tin species with a methanol-water (90% methanol) solution of acetic acid/sodium acetate containing tropolone (0.03% w/ v), their ethylation with NaBEt(4), and separation and detection by GC-FPD. The analytical procedure was optimized with an unspiked sample of harbor porpoise ( Phocoena phocoena) liver. Effects of ASE operational variables (extraction temperature and pressure, solvent composition, number of static extraction steps) are discussed. Method detection limits (MDL) were in the range 6-10 ng(Sn) g(-1) dry weight and 7-17 ng(Sn) g(-1) dry weight for butyl- and phenyltin compounds, respectively. Recoveries were comparable with or better than those obtained by use of other procedures reported in the literature. The analytical procedure was validated by analysis of NIES No. 11 (fish tissue) certified reference material.

  11. Determination of Se in biological samples by axial view inductively coupled plasma optical emission spectrometry after digestion with aqua regia and on-line chemical vapor generation

    Energy Technology Data Exchange (ETDEWEB)

    Santos, Eder Jose dos [Instituto de Tecnologia do Parana (TECPAR), 81350-010 Curitiba, PR (Brazil)], E-mail: eder@tecpar.br; Herrmann, Amanda Beatriz; Kulik de Caires, Suzete [Instituto de Tecnologia do Parana (TECPAR), 81350-010 Curitiba, PR (Brazil); Azzolin Frescura, Vera Lucia; Curtius, Adilson Jose [Departamento de Quimica, Universidade Federal de Santa Catarina (UFSC), 880400-900 Florianopolis, SC (Brazil)

    2009-06-15

    A simple and fast method for the determination of Se in biological samples, including food, by axial view inductively coupled plasma optical emission spectrometry using on-line chemical vapor generation (CVG-ICP OES) is proposed. The concentrations of HCl and NaBH{sub 4}, used in the chemical vapor generation were optimized by factorial analysis. Six certified materials (non-fat milk powder, lobster hepatopancreas, human hair, whole egg powder, oyster tissue, and lyophilised pig kidney) were treated with 10 mL of aqua regia in a microwave system under reflux for 15 min followed by additional 15 min in an ultrasonic bath. The solutions were transferred to a 100 mL volumetric flask and the final volume was made up with water. The Se was determined directly in these solutions by CVG-ICP OES, using the analytical line at 196.026 nm. Calibration against aqueous standards in 10% v/v aqua regia in the concentration range of 0.5-10.0 {mu}g L{sup -} {sup 1} Se(IV) was used for the analysis. The quantification limit, considering a 0.5 g sample weight in a final volume of 100 mL{sup -} {sup 1} was 0.10 {mu}g g{sup -} {sup 1}. The obtained concentration values were in agreement with the total certified concentrations, according to the t-test for a 95% confidence level.

  12. Sensitive determination method for mercury ion, methyl-, ethyl-, and phenyl-mercury in water and biological samples using high-performance liquid chromatography with chemiluminescence detection.

    Science.gov (United States)

    Kodamatani, Hitoshi; Matsuyama, Akito; Saito, Keiitsu; Kono, Yuriko; Kanzaki, Ryo; Tomiyasu, Takashi

    2012-01-01

    A sensitive determination method for mercury speciation analysis was developed. Four mercury species, mercury ion, methylmercury, ethylmercury, and phenylmercury, were complexed with emetine-dithiocarbamate (emetine-CS(2)), and then injected onto a HPLC instrument coupled with a tris(2,2'-bipyridine)ruthenium(III) chemiluminescence detection system. The emetine-CS(2) complexing agent was effectively used to measure the concentration in addition to serving as a separation and detection reagent. The calibration curves for these mercury complexes were linear in the range of 0.050 - 10 μg L(-1) (as Hg). The limit of detection for (emetine-CS(2))(2)Hg, emetine-CS(2)-methylmercury, emetine-CS(2)-ethylmercury, and emetine-CS(2)-phenylmercury were 30, 17, 21, and 22 ng L(-1), respectively. The sensitivity of this method enables the determination of mercury species in water samples at sub-ppb levels. Furthermore, the method was applied to biological samples in combination with acid leaching and liquid-liquid extraction using emetine-CS(2) as an extraction reagent. The determination results were in good agreement with the values of the certified reference materials.

  13. Automated dynamic hollow fiber liquid-liquid-liquid microextraction combined with capillary electrophoresis for speciation of mercury in biological and environmental samples.

    Science.gov (United States)

    Li, Pingjing; He, Man; Chen, Beibei; Hu, Bin

    2015-10-01

    A simple home-made automatic dynamic hollow fiber based liquid-liquid-liquid microextraction (AD-HF-LLLME) device was designed and constructed for the simultaneous extraction of organomercury and inorganic mercury species with the assistant of a programmable flow injection analyzer. With 18-crown-6 as the complexing reagent, mercury species including methyl-, ethyl-, phenyl- and inorganic mercury were extracted into the organic phase (chlorobenzene), and then back-extracted into the acceptor phase of 0.1% (m/v) 3-mercapto-1-propanesulfonic acid (MPS) aqueous solution. Compared with automatic static (AS)-HF-LLLME system, the extraction equilibrium of target mercury species was obtained in shorter time with higher extraction efficiency in AD-HF-LLLME system. Based on it, a new method of AD-HF-LLLME coupled with large volume sample stacking (LVSS)-capillary electrophoresis (CE)/UV detection was developed for the simultaneous analysis of methyl-, phenyl- and inorganic mercury species in biological samples and environmental water. Under the optimized conditions, AD-HF-LLLME provided high enrichment factors (EFs) of 149-253-fold within relatively short extraction equilibrium time (25min) and good precision with RSD between 3.8 and 8.1%. By combining AD-HF-LLLME with LVSS-CE/UV, EFs were magnified up to 2195-fold and the limits of detection (at S/N=3) for target mercury species were improved to be sub ppb level.

  14. Molecularly imprinted polymer on a SiO2 -coated graphene oxide surface for the fast and selective dispersive solid-phase extraction of Carbamazepine from biological samples.

    Science.gov (United States)

    Khalilian, Faezeh; Ahmadian, Setareh

    2016-04-01

    A surface carbamazepine-imprinted polymer was grafted and synthesized on the SiO2 /graphene oxide surface. Firstly SiO2 was coated on synthesized graphene oxide sheet using the sol-gel technique. Prior to polymerization, the vinyl group was incorporated on to the surface of SiO2 /graphene oxide to direct selective polymerization on the surface. Methacrylic acid, ethylene glycol dimethacrylate and ethanol were used as monomer, cross-linker and porogen, respectively. Nonimprinted polymer was also prepared for comparison. The properties of the molecularly imprinted polymer were characterized using field-emission scanning electron microscopy and Fourier-transform infrared spectroscopy. The surface molecularly imprinted polymer was utilized as an adsorbent of dispersive solid-phase extraction for separation and preconcentration of carbamazepine. The effects of the different parameters influencing the extraction efficiency, such as sample pH were investigated and optimized. The specificity of the molecular imprinted polymer over the nonimprinted polymer was examined in absence and presence of competitive drugs. The carbamazepine calibration curve showed linearity in the ranges 0.5-500 μg/L. The limits of detection and quantification under the optimized conditions were 0.1 and 0.3 μg/L, respectively. The within-day and between-day relative standard deviations (n = 3) were 3.6 and 4.3%, respectively. Furthermore, the relative recoveries for spiked biological samples were above 85%.

  15. Non-covalent conjugation of CdTe QDs with lysozyme binding DNA for fluorescent sensing of lysozyme in complex biological sample.

    Science.gov (United States)

    Li, Shujia; Gao, Zhidan; Shao, Na

    2014-11-01

    Water-soluble cysteamine (CA) capped CdTe quantum dots (QDs) conjugated with lysozyme binding DNA (LBD) was constructed for luminescent sensing of lysozyme by forming a ternary self-assembly complex. Addition of negatively charged lysozyme binding DNA to the positively charged CA capped CdTe QDs buffer solution (Tris-HCl pH 7.4) could lead to the formation of QDs-LBD complex through electrostatic interactions. Once lysozyme was introduced into the CdTe QDs-LBD system, it could bind specifically with the QDs-LBD complex, resulting in fluorescence emission enhancement of the QDs due to the surface inert of QDs. At a given amount of LBD and CdTe QDs (LBD: QDs=2: 1), the fluorescence intensity enhancement of QDs was linear with lysozyme concentration over the range of 8.9-71.2 nM, with a detection limit of 4.3 nM. Due to the specific binding of LBD with lysozyme, this approach displayed high selectivity for lysozyme recognition. The sensing mechanism was confirmed by DLS and zeta potential measurement, and agarose gel electrophoresis experiment. Furthermore, the proposed CA-capped CdTe QDs-LBD sensor was applied to lysozyme detection in mouse serum and human morning urine samples, which showed high sensitivity and selectivity in the complex biological sample.

  16. Usefulness of a detector inlet overpressure and stream splitting in FIA systems to deal with food sample pre-treatment requirements. Application to wine analysis

    OpenAIRE

    Lima, José L. F. C.; Rangel,António O. S. S.

    1991-01-01

    The use of stream splitting to obtain high sampling rate flow injection analysis (FIA) large dispersion manifolds to deal with pre-treatment requirements in the analysis of food components with a high concentration is described. This procedure is illustrated in the FIA determination of calcium using an atomic absorption detector and in the colorimetric determination of phosphate in wines. These manifolds proved to be an advantageous alternative to those including mixing chambers and diluters,...

  17. A simple solvothermal process for fabrication of a metal-organic framework with an iron oxide enclosure for the determination of organophosphorus pesticides in biological samples.

    Science.gov (United States)

    Zhang, Suling; Jiao, Zhe; Yao, Weixuan

    2014-12-05

    An active magnetic metal-organic framework (MOF) hybrid material was prepared using a novel in situ solvothermal method in the presence of magnetite (Fe3O4) particles, that holds much promise for large-scale synthesis. MIL-101(Fe), an iron terephthalate with pore structure and high resistance to water and common solvents, was functionalized as a model with superparamagnetic qualities, using Fe3O4. The electrostatic interaction between Fe3O4 and metal ions was thereby used to chemically stabilize magnetic nanoparticles, and thus MOF crystals were uniformly enclosed by Fe3O4 to form a homogeneous magnetic product identified as a Fe3O4/MIL-101 composite. This hybrid material with magnetic susceptibility but with the lowest possible loading amount of Fe3O4 was examined, and its potential application for magnetic solid-phase extraction of six organophosphorus pesticides (OPPs) from human hair and urine samples, followed by gas chromatography analysis, was assessed. The main effect parameters including solution ionic strength, desorption solvent, extraction time and desorption time were investigated in sequence. Under optimized conditions, this method showed low detection limits (0.21-2.28 ng/mL), wide linearity, and good precision (1.8-8.7% for intra-day, 2.9-9.4% for inter-day). The matrix interference produced by hair or urine could be effectively eliminated using this method, and satisfactory recoveries of the spiked samples were 76.8-94.5% and 74.9-92.1%, respectively, indicating that the Fe3O4/MIL-101 sorbents are feasible for the analysis of trace analytes from biological samples.

  18. Fabrication of a Selective and Sensitive Sensor Based on Molecularly Imprinted Polymer/Acetylene Black for the Determination of Azithromycin in Pharmaceuticals and Biological Samples.

    Directory of Open Access Journals (Sweden)

    Tingting Zhou

    Full Text Available A new selective and sensitive sensor based on molecularly imprinted polymer/acetylene black (MIP/AB was developed for the determination of azithromycin (AZM in pharmaceuticals and biological samples. The MIP of AZM was synthesized by precipitation polymerization. MIP and AB were then respectively introduced as selective and sensitive elements for the preparation of MIP/AB-modified carbon paste (MIP/ABP electrode. The performance of the obtained sensor was estimated by cyclic voltammetry (CV and differential pulse voltammetry (DPV techniques. Compared with non-molecularly imprinted polymer (NIP electrodes, NIP/ABP electrodes, and MIP-modified carbon paste electrodes, MIP/ABP electrode exhibited excellent current response toward AZM. The prepared sensor also exhibited good selectivity for AZM in comparison with structurally similar compounds. The effect of electrode composition, extraction parameters, and electrolyte conditions on the current response of the sensor was investigated. Under the optimized conditions, the prepared sensor showed two dynamic linear ranges of 1.0 × 10-7 mol L-1 to 2.0 × 10-6 mol L-1 and 2.0 × 10-6 mol L-1 to 2.0 × 10-5 mol L-1, with a limit of detection of 1.1 × 10-8 mol L-1. These predominant properties ensured that the sensor exhibits excellent reliability for detecting AZM in pharmaceuticals and biological fluids without the assistance of any separation techniques. The results were validated by the high-performance liquid chromatography-tandem mass spectrometry method.

  19. A rapid ultrasound-assisted thiourea extraction method for the determination of inorganic and methyl mercury in biological and environmental samples by CVAAS.

    Science.gov (United States)

    Krishna, M V Balarama; Ranjit, Manjusha; Karunasagar, D; Arunachalam, J

    2005-07-15

    A rapid ultrasound-assisted extraction procedure for the determination of total mercury, inorganic and methyl mercury (MM) in various environmental matrices (animal tissues, samples of plant origin and coal fly ash) has been developed. The mercury contents were estimated by cold vapour atomic absorption spectrometry (CVAAS). Inorganic mercury (IM) was determined using SnCl(2) as reducing agent whereas total mercury was determined after oxidation of methyl mercury through UV irradiation. Operational parameters such as extractant composition (HNO(3) and thiourea), sonication time and sonication amplitude found to be different for different matrices and were optimized using IAEA-350 (Fish homogenate), IM and MM loaded moss and NIST-1633b (Coal fly ash) to get quantitative extraction of total mercury. The method was further validated through the analysis of additional certified reference materials (RM): NRCC-DORM2 (Dogfish muscle), NRCC-DOLT1 (Dogfish liver) and IAEA-336 (Lichen). Quantitative recovery of total Hg was achieved using mixtures of 5% HNO(3) and 0.02% thiourea, 10% HNO(3) and 0.02% thiourea, 20% HNO(3) and 0.2% thiourea for fish tissues, plant matrices and coal fly ash samples, respectively. The results obtained were in close agreement with certified values with an overall precision in the range of 5-15%. The proposed ultrasound-assisted extraction procedure significantly reduces the time required for sample treatment for the extraction of Hg species. The extracted mercury species are very stable even after 24h of sonication. Closed microwave digestion was also used for comparison purposes. The proposed method was applied for the determination of Hg in field samples of lichens, mosses, coal fly ash and coal samples.

  20. Development of sample extraction and clean-up strategies for target and non-target analysis of environmental contaminants in biological matrices.

    Science.gov (United States)

    Baduel, Christine; Mueller, Jochen F; Tsai, Henghang; Gomez Ramos, Maria Jose

    2015-12-24

    Recently, there has been an increasing trend towards multi-targeted analysis and non-target screening methods as a means to increase the number of monitored analytes. Previous studies have developed biomonitoring methods which specifically focus on only a small number of analytes with similar physico-chemical properties. In this paper, we present a simple and rapid multi-residue method for simultaneous extraction of polar and non-polar organic chemicals from biological matrices, containing up to 5% lipid content. Our method combines targeted multi-residue analysis using gas chromatography triple quadrupole mass spectrometry (GC-QqQ-MS/MS) and a multi-targeted analysis complemented with non-target screening using liquid chromatography coupled to a quadrupole time of flight mass spectrometry (LC-QTOF-MS/MS). The optimization of the chemical extraction procedure and the effectiveness of different clean-up methods were evaluated for two biological matrices: fish muscle (lipid content ∼2%) and breast milk (∼4%). To extract a wide range of chemicals, the partition/extraction procedure used for the QuEChERS (Quick, Easy, Cheap, Effective, Rugged and Safe) approach was tested as the initial step for the extraction of 77 target compounds covering a broad compound domain. All the target analytes have different physico-chemical properties (log Kow ranges from -0.3 to 10) and cover a broad activity spectrum; from polar pesticides, pharmaceuticals, personal care products (PPCPs) to highly lipophilic chemicals such as polybrominated diphenyl ethers (PBDEs), polychlorinated biphenyls (PCBs), polycyclic aromatic hydrocarbons (PAHs) and organochloride pesticides (OCPs). A number of options were explored for the clean-up of lipids, proteins and other impurities present in the matrix. Zirconium dioxide-based sorbents as dispersive solid-phase extraction (d-SPE) and protein-lipid removal filter cartridges (Captiva ND Lipids) provided the best results for GC-MS and LC-MS analysis

  1. Achieving Accuracy Requirements for Forest Biomass Mapping: A Data Fusion Method for Estimating Forest Biomass and LiDAR Sampling Error with Spaceborne Data

    Science.gov (United States)

    Montesano, P. M.; Cook, B. D.; Sun, G.; Simard, M.; Zhang, Z.; Nelson, R. F.; Ranson, K. J.; Lutchke, S.; Blair, J. B.

    2012-01-01

    The synergistic use of active and passive remote sensing (i.e., data fusion) demonstrates the ability of spaceborne light detection and ranging (LiDAR), synthetic aperture radar (SAR) and multispectral imagery for achieving the accuracy requirements of a global forest biomass mapping mission. This data fusion approach also provides a means to extend 3D information from discrete spaceborne LiDAR measurements of forest structure across scales much larger than that of the LiDAR footprint. For estimating biomass, these measurements mix a number of errors including those associated with LiDAR footprint sampling over regional - global extents. A general framework for mapping above ground live forest biomass (AGB) with a data fusion approach is presented and verified using data from NASA field campaigns near Howland, ME, USA, to assess AGB and LiDAR sampling errors across a regionally representative landscape. We combined SAR and Landsat-derived optical (passive optical) image data to identify forest patches, and used image and simulated spaceborne LiDAR data to compute AGB and estimate LiDAR sampling error for forest patches and 100m, 250m, 500m, and 1km grid cells. Forest patches were delineated with Landsat-derived data and airborne SAR imagery, and simulated spaceborne LiDAR (SSL) data were derived from orbit and cloud cover simulations and airborne data from NASA's Laser Vegetation Imaging Sensor (L VIS). At both the patch and grid scales, we evaluated differences in AGB estimation and sampling error from the combined use of LiDAR with both SAR and passive optical and with either SAR or passive optical alone. This data fusion approach demonstrates that incorporating forest patches into the AGB mapping framework can provide sub-grid forest information for coarser grid-level AGB reporting, and that combining simulated spaceborne LiDAR with SAR and passive optical data are most useful for estimating AGB when measurements from LiDAR are limited because they minimized

  2. A novel graphene-based label-free fluorescence `turn-on' nanosensor for selective and sensitive detection of phosphorylated species in biological samples and living cells

    Science.gov (United States)

    Ke, Yaotang; Garg, Bhaskar; Ling, Yong-Chien

    2016-02-01

    A novel label-free fluorescence `turn-on' nanosensor has been developed for highly selective and sensitive detection of phosphorylated species (Ps) in biological samples and living cells. The design strategy relies on the use of Ti4+-immobilized polydopamine (PDA) coated reduced graphene oxide (rGO@PDA-Ti4+) that serves as an attractive platform to bind riboflavin 5'-monophosphate molecules (FMNs) through ion-pair interactions between phosphate groups and Ti4+. The as-prepared rGO@PDA-Ti4+-FMNs (nanosensor), fluoresce only weakly due to the ineffective Förster resonance energy transfer between the FMNs and rGO@PDA-Ti4+. The experimental findings revealed that the microwave-assisted interaction of the nanosensor with α-, β-casein, ovalbumin, human serum, non-fat milk, egg white, and living cells (all containing Ps) releases FMNs (due to the high formation constant between phosphate groups and Ti4+), leading to an excellent fluorescence `turn-on' response. The fluorescence spectroscopy, confocal microscopy, and MALDI-TOF MS spectrometry were used to detect Ps both qualitatively and quantitatively. Under the optimized conditions, the nanosensor showed a detection limit of ca. 118.5, 28.9, and 54.8 nM for the tryptic digests of α-, β-casein and ovalbumin, respectively. Furthermore, the standard addition method was used as a bench-mark proof for phosphopeptide quantification in egg white samples. We postulate that the present quantitative assay for Ps holds tremendous potential and may pave the way to disease diagnostics in the near future.A novel label-free fluorescence `turn-on' nanosensor has been developed for highly selective and sensitive detection of phosphorylated species (Ps) in biological samples and living cells. The design strategy relies on the use of Ti4+-immobilized polydopamine (PDA) coated reduced graphene oxide (rGO@PDA-Ti4+) that serves as an attractive platform to bind riboflavin 5'-monophosphate molecules (FMNs) through ion-pair interactions

  3. Soil Sampling to Demonstrate Compliance with Department of Energy Radiological Clearance Requirements for the ALE Unit of the Hanford Reach National Monument

    Energy Technology Data Exchange (ETDEWEB)

    Fritz, Brad G.; Dirkes, Roger L.; Napier, Bruce A.

    2007-04-01

    The Hanford Reach National Monument consists of several units, one of which is the Fitzner/Eberhardt Arid Lands Ecology Reserve (ALE) Unit. This unit is approximately 311 km2 of shrub-steppe habitat located to the south and west of Highway 240. To fulfill internal U. S. Department of Energy (DOE) requirements prior to any radiological clearance of land, DOE must evaluate the potential for residual radioactive contamination on this land and determine compliance with the requirements of DOE Order 5400.5. Historical soil monitoring conducted on ALE indicated soil concentrations of radionuclides were well below the Authorized Limits. However, the historical sampling was done at a limited number of sampling locations. Therefore, additional soil sampling was conducted to determine if the concentrations of radionuclides in soil on the ALE Unit were below the Authorized Limits. This report contains the results of 50 additional soil samples. The 50 soil samples collected from the ALE Unit all had concentrations of radionuclides far below the Authorized Limits. The average concentrations for all detectable radionuclides were less than the estimated Hanford Site background. Furthermore, the maximum observed soil concentrations for the radionuclides included in the Authorized Limits would result in a potential annual dose of 0.14 mrem assuming the most probable use scenario, a recreational visitor. This potential dose is well below the DOE 100-mrem per year dose limit for a member of the public. Spatial analysis of the results indicated no observable statistically significant differences between radionuclide concentrations across the ALE Unit. Furthermore, the results of the biota dose assessment screen, which used the ResRad Biota code, indicated that the concentrations of radionuclides in ALE Unit soil pose no significant health risk to biota.

  4. Molecular detection of human noroviruses in influent and effluent samples from two biological sewage treatment plants in the region of Monastir, Tunisia.

    Science.gov (United States)

    Hassine-Zaafrane, Mouna; Sdiri-Loulizi, Khira; Kaplon, Jérôme; Ben Salem, Imen; Pothier, Pierre; Aouni, Mahjoub; Ambert-Balay, Katia

    2014-06-01

    Noroviruses (NoVs) are responsible for numerous cases of waterborne and foodborne gastroenteritis every year. They are released in the sewage and their detection in this environment can reflect the epidemiology of the viral strains circulating in the community. A three-year (2007-2010) survey was conducted in order to evaluate the presence of human NoVs using RT-PCR in 518 sewage samples collected at the entrance and exit of two biological sewage treatment plants located in Monastir region, Tunisia. In this study, we aimed to genetically characterize the most prevalent GI and GII NoV strains, in order to obtain a rough estimate of the efficacy of disinfection treatments and to compare the results with clinical data documented in the same area during the same period. This work confirms the wide circulation and the genetic diversity of NoVs in Tunisia and the widespread distribution of NoV variants in both raw and treated wastewater. Indeed, NoV was detected in 192 (37.1%) sewage samples, among them mixed infections with group A rotavirus were detected in 125 (65.1%) cases. The genotypes of the GI NoVs were GI.1, GI.2, GI.4, GI.5, and GI of unassigned genotype (GI.UA), and the genotypes of the GII NoVs were all GII.12. This study enhances the currently poor environmental virological data gathered in Tunisia, demonstrates the benefit of environmental surveillance as a tool to determine the epidemiology of NoVs circulating in a given community, and underlines the need for the design and support of similar long-term studies in our country, in order to compensate for the absence of a national surveillance system for gastroenteric viruses.

  5. Mercury analysis of acid- and alkaline-reduced biological samples: identification of meta-cinnabar as the major biotransformed compound in algae.

    Science.gov (United States)

    Kelly, David; Budd, Kenneth; Lefebvre, Daniel D

    2006-01-01

    The biotransformation of Hg(II) in pH-controlled and aerated algal cultures was investigated. Previous researchers have observed losses in Hg detection in vitro with the addition of cysteine under acid reduction conditions in the presence of SnCl2. They proposed that this was the effect of Hg-thiol complexing. The present study found that cysteine-Hg, protein and nonprotein thiol chelates, and nucleoside chelates of Hg were all fully detectable under acid reduction conditions without previous digestion. Furthermore, organic (R-Hg) mercury compounds could not be detected under either the acid or alkaline reduction conditions, and only beta-HgS was detected under alkaline and not under acid SnCl2 reduction conditions. The blue-green alga Limnothrix planctonica biotransformed the bulk of Hg(II) applied as HgCl2 into a form with the analytical properties of beta-HgS. Similar results were obtained for the eukaryotic alga Selenastrum minutum. No evidence for the synthesis of organomercurials such as CH3Hg+ was obtained from analysis of either airstream or biomass samples under the aerobic conditions of the study. An analytical procedure that involved both acid and alkaline reduction was developed. It provides the first selective method for the determination of beta-HgS in biological samples. Under aerobic conditions, Hg(II) is biotransformed mainly into beta-HgS (meta-cinnabar), and this occurs in both prokaryotic and eukaryotic algae. This has important implications with respect to identification of mercury species and cycling in aquatic habitats.

  6. Electrochemically reduced graphene oxide-based electrochemical sensor for the sensitive determination of ferulic acid in A. sinensis and biological samples.

    Science.gov (United States)

    Liu, Linjie; Gou, Yuqiang; Gao, Xia; Zhang, Pei; Chen, Wenxia; Feng, Shilan; Hu, Fangdi; Li, Yingdong

    2014-09-01

    An electrochemically reduced graphene oxide (ERGO) modified glassy carbon electrode (GCE) was used as a new voltammetric sensor for the determination of ferulic acid (FA). The morphology and microstructure of the modified electrodes were characterized by scanning electron microscopy (SEM) and Raman spectroscopy analysis, and the electrochemical effective surface areas of the modified electrodes were also calculated by chronocoulometry method. Sensing properties of the electrochemical sensor were investigated by means of cyclic voltammetry (CV) and differential pulse voltammetry (DPV). It was found that ERGO was electrodeposited on the surface of GCE by using potentiostatic method. The proposed electrode exhibited electrocatalytic activity to the redox of FA because of excellent electrochemical properties of ERGO. The transfer electron number (n), electrode reaction rate constant (ks) and electron-transfer coefficient (α) were calculated as 1.12, 1.24s(-1), and 0.40, respectively. Under the optimized conditions, the oxidation peak current was proportional to FA concentration at 8.49 × 10(-8)mol L(-1) to 3.89 × 10(-5)mol L(-1) with detection limit of 2.06 × 10(-8)mol L(-1). This fabricated sensor also displayed acceptable reproducibility, long-term stability, and high selectivity with negligible interferences from common interfering species. The voltammetric sensor was successfully applied to detect FA in A. sinensis and biological samples with recovery values in the range of 99.91%-101.91%.

  7. Electrochemical preparation of a molecularly imprinted polypyrrole modified pencil graphite electrode for the determination of phenothiazine in model and real biological samples.

    Science.gov (United States)

    Nezhadali, Azizollah; Rouki, Zohreh; Nezhadali, Mohammad

    2015-11-01

    A sensitive electrochemical sensor for determination of phenothiazine (PTZ) was introduced based on molecularly imprinted polymer (MIP) film. A computational study was performed to evaluate the template-monomer geometry and interaction energy in the prepolymerization mixture. The electrode was prepared during electropolymerization of pyrrole (Py) on a pencil graphite electrode (PGE) by cyclic voltammetry (CV) technique. The quantitative measurements were performed using differential pulse voltammetry (DPV) in Britton-Robinson (BR) buffer solutions using 60% (v/v) acetonitrile-water (ACN/H2O) binary solvent. The effect of important parameters like pH, monomer concentration, number of cycles, etc on the efficiency of MIP electrode was optimized and the calibration curve was plotted at optimal conditions. Two dynamic linear ranges of 1-300 µmol L(-1) and 0.5-10 mmol L(-1) were observed. The detection limit (based on S/N=3) of PTZ was obtained 3×10(-7) mol L(-1). The MIP/PGE has been successfully applied as a selective sensor for fast and accurate determination of PTZ in some model and real biological samples.

  8. Analytical tools for determination of new oral antidiabetic drugs, glitazones, gliptins, gliflozins and glinides, in bulk materials, pharmaceuticals and biological samples

    Directory of Open Access Journals (Sweden)

    Gumieniczek Anna

    2016-01-01

    Full Text Available The review presents analytical methods for determination of new oral drugs for the treatment of type 2 diabetes mellitus (T2DM, focusing on peroxisome proliferator-activated receptor gamma agonists (glitazones, dipeptidyl peptidase 4 inhibitors (gliptins and sodium/glucose co-transporter 2 inhibitors (gliflozins. Drugs derived from prandial glucose regulators, such as glinides, are considered because they are present in some new therapeutic options. The review presents analytical procedures suitable for determination of the drugs in bulk substances, such as pharmaceuticals and biological samples, including HPLC-UV, HPLC/LC-MS, TLC/HPTLC, CE/CE-MS, spectrophotometric (UV/VIS, spectrofluorimetric and electrochemical methods, taken from the literature over the past ten years (2006-2016. Some new procedures for extraction, separation and detection of the drugs, including solid phase extraction with molecularly imprinted polymers (SPE-MIP, liquid phase microextraction using porous hollow fibers (HP-LPME, HILIC chromatography, micellar mobile phases, ion mobility spectrometry (IMS and isotopically labeled internal standards, are discussed.

  9. One-pot synthesis of quantum dot-labeled hydrophilic molecularly imprinted polymer nanoparticles for direct optosensing of folic acid in real, undiluted biological samples.

    Science.gov (United States)

    Yang, Yaqiong; Wang, Zhengzheng; Niu, Hui; Zhang, Huiqi

    2016-12-15

    A facile and efficient one-pot approach for the synthesis of quantum dot (QD)-labeled hydrophilic molecularly imprinted polymer (MIP) nanoparticles for direct optosensing of folic acid (FA) in the undiluted bovine and porcine serums is described. Hydrophilic macromolecular chain transfer agent-mediated reversible addition-fragmentation chain transfer (RAFT) precipitation polymerization was used to implement the molecular imprinting of FA in the presence of CdTe quantum dots (QDs). The resulting FA-imprinted polymer nanoparticles with surface-grafted hydrophilic poly(glyceryl monomethacrylate) brushes and QDs labeling not only showed outstanding specific molecular recognition toward FA in biological samples, but also exhibited good photostability, rapid binding kinetics, and obvious template binding-induced fluorescence quenching. These characteristics make them a useful fluorescent chemosensor for directly and selectively optosensing FA in the undiluted bovine and porcine serums, with its limit of detection being 0.025μM and average recoveries ranging from 98% to 102%, even in the presence of several interfering compounds. This advanced fluorescent MIP chemosensor is highly promising for rapid quantification of FA in such applications as clinical diagnostics and food analysis.

  10. Necessity of 3D visualization for the removal of lower wisdom teeth: required sample size to prove non-inferiority of panoramic radiography compared to CBCT.

    Science.gov (United States)

    Roeder, Felix; Wachtlin, Daniel; Schulze, Ralf

    2012-06-01

    The availability of cone beam computed tomography (CBCT) and the numbers of CBCT scans rise constantly, increasing the radiation burden to the patient. A growing discussion is noticeable if a CBCT scan prior to the surgical removal of wisdom teeth may be indicated. We aimed to confirm non-inferiority with respect to damage of the inferior alveolar nerve in patients diagnosed by panoramic radiography compared to CBCT in a prospective randomized controlled multicentre trial. Sample size (number of required third molar removals) was calculated for the study and control groups as 183,474 comparing temporary and 649,036 comparing permanent neurosensory disturbances of the inferior alveolar nerve. Modifying parameter values resulted in sample sizes ranging from 39,584 to 245,724 respectively 140,024 to 869,250. To conduct a clinical study to prove a potential benefit from CBCT scans prior to surgical removal of lower wisdom teeth with respect to the most important parameter, i.e., nerval damage, is almost impossible due to the very large sample sizes required. This fact vice versa indicates that CBCT scans should only be performed in high risk wisdom tooth removals.

  11. Evaluation of status of cadmium, lead, and nickel levels in biological samples of normal and night blindness children of age groups 3-7 and 8-12 years.

    Science.gov (United States)

    Afridi, Hassan Imran; Kazi, Tasneem Gul; Kazi, Naveed; Sirajuddin; Kandhro, Ghulam Abbas; Baig, Jameel Ahmed; Shah, Abdul Qadir; Wadhwa, Sham Kumar; Khan, Sumaira; Kolachi, Nida Fatima; Shah, Faheem; Jamali, Mohammad Khan; Arain, Mohammad Balal

    2011-09-01

    The causes of night blindness in children are multifactorial, and particular consideration has been given to childhood trace metals toxicity, which is the most common problem found in underdeveloped countries. This study was designed to compare the levels of cadmium (Cd), lead (Pb), and nickel (Ni) in scalp hair, blood, and urine of night blindness children age ranged 3-7 and 8-12 years of both genders, comparing them to sex- and age-matched controls. A microwave-assisted wet acid digestion procedure was developed as a sample pretreatment, for the determination of Cd, Pb, and Ni in biological samples of night blindness children. The proposed method was validated by using conventional wet digestion and certified reference samples of hair, blood, and urine. The digests of all biological samples were analyzed for Cd, Pb, and Ni by electrothermal atomic absorption spectrometry. The results indicated significantly higher levels of Cd, Pb, and Ni in the biological samples (blood, scalp hair, and urine) of male and female night blindness children, compared with control subjects of both genders. These data present guidance to clinicians and other professional investigating toxicity of trace metals in biological samples of night blindness children.

  12. A Simple and Selective Spectrophotometric Method for the Determination of Trace Gold in Real, Environmental, Biological, Geological and Soil Samples Using Bis (Salicylaldehyde Orthophenylenediamine

    Directory of Open Access Journals (Sweden)

    Rubina Soomro

    2008-01-01

    Full Text Available A simple high sensitive, selective, and rapid spectrophotometric method for the determination of trace gold based on the rapid reaction of gold(III with bis(salicylaldehydeorthophenylenediamine (BSOPD in aqueous and micellar media has been developed. BSOPD reacts with gold(III in slightly acidic solution to form a 1:1 brownish-yellow complex, which has an maximum absorption peak at 490 nm in both aqueous and micellar media. The most remarkable point of this method is that the molar absorptivities of the gold-BSOPD complex form in the presence of the nonionic TritonX-100 surfactant are almost a 10 times higher than the value observed in the aqueous solution, resulting in an increase in the sensitivity and selectivity of the method. The apparent molar absorptivities were found to be 2.3 × 104 L mol−1 cm−1 and 2.5 × 105 L mol−1 cm−1 in aqueous and micellar media, respectively. The reaction is instantaneous and the maximum absorbance was obtained after 10 min at 490 nm and remains constant for over 24 h at room temperature. The linear calibration graphs were obtained for 0.1 –30 mg L−1 and 0.01 –30 mg L−1 of gold(III in aqueous and surfactant media, respectively. The interference from over 50 cations, anions and complexing agents has been studied at 1 mg L−1 of Au(III; most metal ions can be tolerated in considerable amounts in aqueous micellar solutions. The Sandell’s sensitivity, the limit of detection and relative standard deviation (n = 9 were found to be 5 ng cm−2, 1 ng mL−1 and 2%, respectively in aqueous micellar solutions. Its sensitivity and selectivity are remarkably higher than that of other reagents in the literature. The proposed method was successfully used in the determination of gold in several standard reference materials (alloys and steels, environmental water samples (potable and polluted, and biological samples (blood and urine, geological, soil and complex synthetic mixtures. The results obtained agree

  13. Ancestral state reconstructions require biological evidence to test evolutionary hypotheses: A case study examining the evolution of reproductive mode in squamate reptiles.

    Science.gov (United States)

    Griffith, Oliver W; Blackburn, Daniel G; Brandley, Matthew C; Van Dyke, James U; Whittington, Camilla M; Thompson, Michael B

    2015-09-01

    To understand evolutionary transformations it is necessary to identify the character states of extinct ancestors. Ancestral character state reconstruction is inherently difficult because it requires an accurate phylogeny, character state data, and a statistical model of transition rates and is fundamentally constrained by missing data such as extinct taxa. We argue that model based ancestral character state reconstruction should be used to generate hypotheses but should not be considered an analytical endpoint. Using the evolution of viviparity and reversals to oviparity in squamates as a case study, we show how anatomical, physiological, and ecological data can be used to evaluate hypotheses about evolutionary transitions. The evolution of squamate viviparity requires changes to the timing of reproductive events and the successive loss of features responsible for building an eggshell. A reversal to oviparity requires that those lost traits re-evolve. We argue that the re-evolution of oviparity is inherently more difficult than the reverse. We outline how the inviability of intermediate phenotypes might present physiological barriers to reversals from viviparity to oviparity. Finally, we show that ecological data supports an oviparous ancestral state for squamates and multiple transitions to viviparity. In summary, we conclude that the first squamates were oviparous, that frequent transitions to viviparity have occurred, and that reversals to oviparity in viviparous lineages either have not occurred or are exceedingly rare. As this evidence supports conclusions that differ from previous ancestral state reconstructions, our paper highlights the importance of incorporating biological evidence to evaluate model-generated hypotheses.

  14. Telomere length is a biomarker of cumulative oxidative stress, biologic age, and an independent predictor of survival and therapeutic treatment requirement associated with smoking behavior.

    Science.gov (United States)

    Babizhayev, Mark A; Savel'yeva, Ekaterina L; Moskvina, Svetlana N; Yegorov, Yegor E

    2011-11-01

    Globally, tobacco use is associated with 5 million deaths per annum and is regarded as one of the leading causes of premature death. Major chronic disorders associated with smoking include cardiovascular diseases, several types of cancer, and chronic obstructive pulmonary disease (lung problems). Cigarette smoking (CS) generates a cumulative oxidative stress, which may contribute to the pathogenesis of chronic diseases. Mainstream and side stream gas-phase smoke each have about the same concentration of reactive free radical species, about 1 × 10(16) radicals per cigarette (or 5 × 10(14) per puff). This effect is critical in understanding the biologic effects of smoke. Several lines of evidence suggest that cigarette smoke constituents can directly activate vascular reactive oxygen species production. In this work we present multiple evidence that CS provide the important risk factors in many age-related diseases, and is associated with increased cumulative and systemic oxidative stress and inflammation. The cited processes are marked by increased white blood cell (leucocytes, WBCs) turnover. The data suggest an alteration of the circulating WBCs by CS, resulting in increased adherence to endothelial cells. Telomeres are complex DNA-protein structures located at the end of eukaryotic chromosomes. Telomere length shortens with biologic age in all replicating somatic cells. It has been shown that tobacco smoking enhances telomere shortening in circulating human WBCs. Telomere attrition (expressed in WBCs) can serve as a biomarker of the cumulative oxidative stress and inflammation induced by smoking and, consequently, show the pace of biologic aging. We originally propose that patented specific oral formulations of nonhydrolized carnosine and carcinine provide a powerful tool for targeted therapeutic inhibition of cumulative oxidative stress and inflammation and protection of telomere attrition associated with smoking. The longitudinal studies of the clinical

  15. Computer Assisted Examination of Infrared and Near Infrared Spectra to Assess Structural and Molecular Changes in Biological Samples Exposed to Pollutants: A Case of Study

    Directory of Open Access Journals (Sweden)

    Mauro Mecozzi

    2017-02-01

    Full Text Available We present a computer assisted method for the examination of the structural changes present in the probe organism Vicia faba exposed to inorganic arsenic, detected by means of Fourier transform infrared (FTIR and Fourier transform near infrared (FTNIR spectroscopy. Like the common ecotoxicological tests, the method is based on the comparison among control and exposed sample spectra of the organisms to detect structural changes caused by pollutants. Using FTIR spectroscopy, we measured and plotted the spectral changes related to the unsaturated to saturated lipid ratio changes (USL, the lipid to protein ratio changes (LPR, fatty and ester fatty acid content changes (FA, protein oxidation (PO and denaturation, and DNA and RNA changes (DNA-RNA. Using FTNIR spectroscopy, we measured two spectral ranges that belonged to hydrogen bond interactions and aliphatic lipid chains called IntHCONH and Met1overt, respectively. The FTIR results showed that As modified the DNA-RNA ratio and also caused partial protein denaturation in the Vicia faba samples. The FTNIR results supported the FTIR results. The main advantage of the proposed computational method is that it does not require a skilled infrared or near infrared operator, lending support to conventional studies performed by toxicological testing.

  16. Optimizing trial design in pharmacogenetics research: comparing a fixed parallel group, group sequential, and adaptive selection design on sample size requirements.

    Science.gov (United States)

    Boessen, Ruud; van der Baan, Frederieke; Groenwold, Rolf; Egberts, Antoine; Klungel, Olaf; Grobbee, Diederick; Knol, Mirjam; Roes, Kit

    2013-01-01

    Two-stage clinical trial designs may be efficient in pharmacogenetics research when there is some but inconclusive evidence of effect modification by a genomic marker. Two-stage designs allow to stop early for efficacy or futility and can offer the additional opportunity to enrich the study population to a specific patient subgroup after an interim analysis. This study compared sample size requirements for fixed parallel group, group sequential, and adaptive selection designs with equal overall power and control of the family-wise type I error rate. The designs were evaluated across scenarios that defined the effect sizes in the marker positive and marker negative subgroups and the prevalence of marker positive patients in the overall study population. Effect sizes were chosen to reflect realistic planning scenarios, where at least some effect is present in the marker negative subgroup. In addition, scenarios were considered in which the assumed 'true' subgroup effects (i.e., the postulated effects) differed from those hypothesized at the planning stage. As expected, both two-stage designs generally required fewer patients than a fixed parallel group design, and the advantage increased as the difference between subgroups increased. The adaptive selection design added little further reduction in sample size, as compared with the group sequential design, when the postulated effect sizes were equal to those hypothesized at the planning stage. However, when the postulated effects deviated strongly in favor of enrichment, the comparative advantage of the adaptive selection design increased, which precisely reflects the adaptive nature of the design.

  17. Application of the k{sub 0}-INAA method for analysis of biological samples at the pneumatic station of the IEA-R1 nuclear research reactor

    Energy Technology Data Exchange (ETDEWEB)

    Puerta, Daniel C.; Figueiredo, Ana Maria G.; Semmler, Renato, E-mail: dcpuerta@hotmail.com, E-mail: anamaria@ipen.br, E-mail: rsemmler@ipen.br [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil); Jacimovic, Radojko, E-mail: radojko.jacimovic@ijs.si [Jozef Stefan Institute (JSI), Ljubljana, LJU (Slovenia). Department of Environmental Sciences

    2013-07-01

    As part of the process of implementation of the k{sub 0}-INAA standardization method at the Neutron Activation Laboratory (LAN-IPEN), Sao Paulo, Brazil, this study presents the results obtained for the analysis of short and medium-lived nuclides in biological samples by k{sub 0}-INAA using the program k{sub 0}-IAEA, provided by the International Atomic Energy Agency (IAEA). The elements Al, Ba, Br, Na, K, Mn, Mg, Sr and V were determined with respect to gold ({sup 197}Au) using the pneumatic station facility of the IEA-R1 4.5 MW swimming pool nuclear research reactor, Sao Paulo. Characterization of the pneumatic station was carried out by using the 'bare triple-monitor' method with {sup 197}Au-{sup 96}Zr-{sup 94}Zr. The Certified Reference Material IRMM-530R Al-0.1%Au alloy and high purity zirconium comparators were used. The efficiency curves of the gamma-ray spectrometer used were determined by measuring calibrated radioactive sources at the usually utilized counting geometries. The method was validated by analyzing the reference materials NIST SRM 1547 Peach Leaves, INCT-MPH-2 Mixed Polish Herbs and NIST SRM 1573a Tomato Leaves. The concentration results obtained agreed with certified, reference and recommended values, showing relative errors (bias, %) less than 30% for most elements. The Coefficients of Variation were below 20%, showing a good reproducibility of the results. The E{sub n}-number showed that all results, except Na in NIST SRM 1547 and NIST SRM 1573a and Al in INCT-MPH-2, were within 95% confidence interval. (author)

  18. 环境和生物样品中痕量双酚A的分析方法%Determination of Trace Bisphenol A in Environmental and Biological Samples

    Institute of Scientific and Technical Information of China (English)

    王晓春; 刘晓端; 杨永亮; 李刚; 徐清; 焦杏春; 罗松光; 李奇

    2009-01-01

    作为环境类内分泌干扰物之一,双酚A由于被广泛作为化工原料使用而对环境和人类健康产生了严重的危害.文章对近年来国内外环境及生物样品中残留双酚A的最新前处理及检测技术的研究进展进行了综述.除常规前处理技术外,还介绍了包括搅拌棒吸附萃取及分子印迹等新型分离、富集技术在双酚A提取中的应用;另外,在着重介绍双酚A的色谱-质谱分析技术的基础上,对免疫分析、传感器检测和光学检测在双酚A检测中的应用也进行了详细报道.展望双酚A分析的发展趋势,二级串联质谱由于具有比其他分析方法更低的检出限,因此将会成为检测环境及生物样品中痕量双酚A的最具潜力的手段之一;研制价格低廉、重现性好、高通量的微型化、便携式、自动化仪器将是在线快速分析双酚A的另一个主要发展方向.%As one of the environmental endocrine-disrupting chemicals, bisphenol A produces great harm to the environment and the human health due to its widespread use as the raw materials in chemical industry. This paper reviews the recent technical developments in the determination of trace bisphenol A in environmental and biological samples including sample separation, enrichment and analytical methods. Except for the regular sample pretreatment techniques, the applications of popular sample pretreatment technique such as stir bar sorptive extraction and molecular imprinting technique were also discussed. On the basis of the discussion on application of chromatography-mass spectrometry for bisphenol A analysis, the application of immunoassay, biosensor and optical detection techniques for bisphenol A analysis were also reported in detail. Finally, the trend in development of bisphenol A analysis techniques was prospected. The tandem mass spectrometry may be one of the potential analytical techniques for bisphenol A analysis due to its low detection limit. In

  19. An Evaluation of Teachers' Attitudes and Beliefs Levels on Classroom Control in Terms of Teachers' Sense of Efficacy (The Sample of Biology Teachers in Turkey)

    Science.gov (United States)

    Kurt, Hakan

    2014-01-01

    The aim of this study is to evaluate biology teachers' attitudes and belief levels on classroom control in terms of teachers' sense of efficacy. The screening model was used in the study. The study group was comprised of 135 biology teachers. In this study, Teachers' Sense of Efficacy Scale (TSES) and The Attitudes and Beliefs on Classroom Control…

  20. Application of the ESRI Geostatistical Analyst for Determining the Adequacy and Sample Size Requirements of Ozone Distribution Models in the Carpathian and Sierra Nevada Mountains

    Directory of Open Access Journals (Sweden)

    Witold Fraczek

    2001-01-01

    Full Text Available Models of O3 distribution in two mountain ranges, the Carpathians in Central Europe and the Sierra Nevada in California were constructed using ArcGIS Geostatistical Analyst extension (ESRI, Redlands, CA using kriging and cokriging methods. The adequacy of the spatially interpolated ozone (O3 concentrations and sample size requirements for ozone passive samplers was also examined. In case of the Carpathian Mountains, only a general surface of O3 distribution could be obtained, partially due to a weak correlation between O3 concentration and elevation, and partially due to small numbers of unevenly distributed sample sites. In the Sierra Nevada Mountains, the O3 monitoring network was much denser and more evenly distributed, and additional climatologic information was available. As a result the estimated surfaces were more precise and reliable than those created for the Carpathians. The final maps of O3 concentrations for Sierra Nevada were derived from cokriging algorithm based on two secondary variables — elevation and maximum temperature as well as the determined geographic trend. Evenly distributed and sufficient numbers of sample points are a key factor for model accuracy and reliability.