WorldWideScience

Sample records for bioflumen biological fluid

  1. Microgravity Fluids for Biology, Workshop

    Science.gov (United States)

    Griffin, DeVon; Kohl, Fred; Massa, Gioia D.; Motil, Brian; Parsons-Wingerter, Patricia; Quincy, Charles; Sato, Kevin; Singh, Bhim; Smith, Jeffrey D.; Wheeler, Raymond M.

    2013-01-01

    Microgravity Fluids for Biology represents an intersection of biology and fluid physics that present exciting research challenges to the Space Life and Physical Sciences Division. Solving and managing the transport processes and fluid mechanics in physiological and biological systems and processes are essential for future space exploration and colonization of space by humans. Adequate understanding of the underlying fluid physics and transport mechanisms will provide new, necessary insights and technologies for analyzing and designing biological systems critical to NASAs mission. To enable this mission, the fluid physics discipline needs to work to enhance the understanding of the influence of gravity on the scales and types of fluids (i.e., non-Newtonian) important to biology and life sciences. In turn, biomimetic, bio-inspired and synthetic biology applications based on physiology and biology can enrich the fluid mechanics and transport phenomena capabilities of the microgravity fluid physics community.

  2. Magnetic movement of biological fluid droplets

    International Nuclear Information System (INIS)

    Garcia, Antonio A.; Egatz-Gomez, Ana; Lindsay, Solitaire A.; Dominguez-Garcia, P.; Melle, Sonia; Marquez, Manuel; Rubio, Miguel A.; Picraux, S.T.; Yang, Dongqing; Aella, P.; Hayes, Mark A.; Gust, Devens; Loyprasert, Suchera; Vazquez-Alvarez, Terannie; Wang, Joseph

    2007-01-01

    Magnetic fields can be used to control the movement of aqueous drops on non-patterned, silicon nanowire superhydrophobic surfaces. Drops of aqueous and biological fluids are controlled by introducing magnetizable carbonyl iron microparticles into the liquid. Key elements of operations such as movement, coalescence, and splitting of water and biological fluid drops, as well as electrochemical measurement of an analyte are demonstrated. Superhydrophobic surfaces were prepared using vapor-liquid-solid (VLS) growth systems followed by coating with a perfluorinated hydrocarbon molecule. Drops were made from aqueous and biological fluid suspensions with magnetizable microparticle concentrations ranging from 0.1 to 10 wt%

  3. Magnetic movement of biological fluid droplets

    Energy Technology Data Exchange (ETDEWEB)

    Garcia, Antonio A. [Harrington Department of Bioengineering, Arizona State University, Tempe, AZ 85287 (United States)]. E-mail: tony.garcia@asu.edu; Egatz-Gomez, Ana [Harrington Department of Bioengineering, Arizona State University, Tempe, AZ 85287 (United States); Lindsay, Solitaire A. [Harrington Department of Bioengineering, Arizona State University, Tempe, AZ 85287 (United States); Dominguez-Garcia, P. [Departamento de Fisica Fundamental, UNED, Senda del Rey 9, Madrid 28040 (Spain); Melle, Sonia [Harrington Department of Bioengineering, Arizona State University, Tempe, AZ 85287 (United States); Departamento de Optica, Universidad Complutense de Madrid, Arcos de Jalon s/n, Madrid 28037 (Spain); Marquez, Manuel [Harrington Department of Bioengineering, Arizona State University, Tempe, AZ 85287 (United States); Research Center, Philip Morris USA, Richmond, VA 23234 (United States); Rubio, Miguel A. [Departamento de Fisica Fundamental, UNED, Senda del Rey 9, Madrid 28040 (Spain); Picraux, S.T. [Department of Chemical and Materials Engineering, Arizona State University, Tempe, AZ 85287 (United States); Los Alamos National Laboratory, MST-CINT, Los Alamos, NM 87545 (United States); Yang, Dongqing [Department of Chemical and Materials Engineering, Arizona State University, Tempe, AZ 85287 (United States); Aella, P. [Department of Chemical and Materials Engineering, Arizona State University, Tempe, AZ 85287 (United States); Hayes, Mark A. [Department of Chemistry and Biochemistry, Arizona State University, Tempe, AZ 8528 (United States); Gust, Devens [Department of Chemistry and Biochemistry, Arizona State University, Tempe, AZ 8528 (United States); Loyprasert, Suchera [Biodesign Institute, Arizona State University, Tempe, AZ 85287 (United States); Vazquez-Alvarez, Terannie [Biodesign Institute, Arizona State University, Tempe, AZ 85287 (United States); Wang, Joseph [Biodesign Institute, Arizona State University, Tempe, AZ 85287 (United States)

    2007-04-15

    Magnetic fields can be used to control the movement of aqueous drops on non-patterned, silicon nanowire superhydrophobic surfaces. Drops of aqueous and biological fluids are controlled by introducing magnetizable carbonyl iron microparticles into the liquid. Key elements of operations such as movement, coalescence, and splitting of water and biological fluid drops, as well as electrochemical measurement of an analyte are demonstrated. Superhydrophobic surfaces were prepared using vapor-liquid-solid (VLS) growth systems followed by coating with a perfluorinated hydrocarbon molecule. Drops were made from aqueous and biological fluid suspensions with magnetizable microparticle concentrations ranging from 0.1 to 10 wt%.

  4. Radioimmunoassay of penicilloyl groups in biological fluids

    International Nuclear Information System (INIS)

    Wal, J-M.; Bories, G.

    1975-01-01

    Penicilloyl-protein conjugates may be formed in man or animals after therapeutic treatment but cannot be detected by the classical microbiological assay methods used for penicillin. Allergies have been noted in consumers of products coming from animals treated with penicillin (milk particularly). Although these compounds present a risk to public health, they passed unnoticed through hygienic food inspection. Therefore a specific and sensitive method was devised for the assay of these derivatives in biological fluids where they can be present in trace amounts. An iodine-125 labelled conjugate has been prepared. Already usable for the detection of antipenicilloyl antibodies in sera of penicillin allergic patients, it has been used for the development of a radioimmunoassay of penicilloyl groups. Assay is done directly on milk, urine and serum without previous extraction and with a detection limit of a few ppb. It permits a rapid, specific and easy to handle determination in the sera of hospital patients as well as in the inspection of animal products at the slaughter house and at the dairy

  5. Methods for analysis of fluoroquinolones in biological fluids

    Science.gov (United States)

    Methods for analysis of 10 selected fluoroquinolone antibiotics in biological fluids are reviewed. Approaches for sample preparation, detection methods, limits of detection and quantitation and recovery information are provided for both single analyte and multi-analyte fluoroquinolone methods....

  6. Complex fluids in biological systems experiment, theory, and computation

    CERN Document Server

    2015-01-01

    This book serves as an introduction to the continuum mechanics and mathematical modeling of complex fluids in living systems. The form and function of living systems are intimately tied to the nature of surrounding fluid environments, which commonly exhibit nonlinear and history dependent responses to forces and displacements. With ever-increasing capabilities in the visualization and manipulation of biological systems, research on the fundamental phenomena, models, measurements, and analysis of complex fluids has taken a number of exciting directions. In this book, many of the world’s foremost experts explore key topics such as: Macro- and micro-rheological techniques for measuring the material properties of complex biofluids and the subtleties of data interpretation Experimental observations and rheology of complex biological materials, including mucus, cell membranes, the cytoskeleton, and blood The motility of microorganisms in complex fluids and the dynamics of active suspensions Challenges and solut...

  7. Fluid dynamics in biological active nematics

    Science.gov (United States)

    Tan, Amanda; Hirst, Linda

    We use biological materials to form a self-mixing active system that consists of microtubules driven by kinesin clusters. Microtubules are rigid biopolymers that are a part of the cytoskeleton. Kinesin motors are molecular motors that walk along microtubules to transport cellular cargo. In this system, microtubules are bundled together, and as the kinesin clusters walk along the filaments, the microtubule bundles move relative to each other. As microtubules shear against each other, they extend, bend, buckle and fracture. When confined in a 2D water-oil interface, the system becomes an active nematic that self-mixes due to the buckling and fracturing. To quantify this self-mixing, we attached beads to the microtubules, and tracked their motion. We quantify the quality of mixing using the bead trajectories. This new active material has potential applications as a self-mixing solvent. CCBM NSF-CREST, UC Merced Health Science Research Institute.

  8. [Biologic tests for the diagnosis of amniotic fluid embolism].

    Science.gov (United States)

    Van Cortenbosch, B; Huel, C; Houfflin Debarge, V; Luton, D; Lambaudie, E; Porquet, D; Guibourdenche, J

    2007-01-01

    Amniotic fluid embolism is a rare, unpredictable and often lethal complication of pregnancy and childbirth. Because of its variable presentation, an early biologic test would help to establish the diagnosis. We investigated in maternal serum 4 components of amniotic fluid, i.e., alpha-fetoprotein (AFP), l'insuline like growth factor binding protein-1 (IGFBP-1), fetal fibronectin (fFN) and placental alpha1-microglobulin (PAMG-1). On the 6 cesareans controls involved, none of the makers increased after membranes section. PAMG-1 is unsuitable because its detection is always positive or doubtful even in the baseline. On the 7 cases suspected of amniotic fluid embolism, no detectable increase in any of those markers was noted in 3 cases, which is not in favour of this diagnosis. In the remaining cases, IGFBP-1 and fFN became detectable, confirming histological evidences of amniotic fluid embolism in 2 cases. The follow up of those markers in maternal blood confirmed the suspicion of amniotic fluid embolism at 21 wg in one case of ongoing pregnancy. These preliminary results point out the potential interest to assay maternal serum AFP, IGFBP-1 and fFN to confirm amniotic fluid embolism using rapid laboratory tests.

  9. Nano- and microparticles at fluid and biological interfaces

    Science.gov (United States)

    Dasgupta, S.; Auth, T.; Gompper, G.

    2017-09-01

    Systems with interfaces are abundant in both technological applications and biology. While a fluid interface separates two fluids, membranes separate the inside of vesicles from the outside, the interior of biological cells from the environment, and compartmentalize cells into organelles. The physical properties of interfaces are characterized by interface tension, those of membranes are characterized by bending and stretching elasticity. Amphiphilic molecules like surfactants that are added to a system with two immiscible fluids decrease the interface tension and induce a bending rigidity. Lipid bilayer membranes of vesicles can be stretched or compressed by osmotic pressure; in biological cells, also the presence of a cytoskeleton can induce membrane tension. If the thickness of the interface or the membrane is small compared with its lateral extension, both can be described using two-dimensional mathematical surfaces embedded in three-dimensional space. We review recent work on the interaction of particles with interfaces and membranes. This can be micrometer-sized particles at interfaces that stabilise emulsions or form colloidosomes, as well as typically nanometer-sized particles at membranes, such as viruses, parasites, and engineered drug delivery systems. In both cases, we first discuss the interaction of single particles with interfaces and membranes, e.g. particles in external fields, non-spherical particles, and particles at curved interfaces, followed by interface-mediated interaction between two particles, many-particle interactions, interface and membrane curvature-induced phenomena, and applications.

  10. Analytical Problems in Exposing Amperometric Enzyme Biosensors to Biological Fluids

    Directory of Open Access Journals (Sweden)

    Gaia Rocchitta

    2016-05-01

    Full Text Available Enzyme-based chemical biosensors are based on biological recognition. In order to operate, the enzymes must be available to catalyze a specific biochemical reaction and be stable under the normal operating conditions of the biosensor. Design of biosensors is based on knowledge about the target analyte, as well as the complexity of the matrix in which the analyte has to be quantified. This article reviews the problems resulting from the interaction of enzyme-based amperometric biosensors with complex biological matrices containing the target analyte(s. One of the most challenging disadvantages of amperometric enzyme-based biosensor detection is signal reduction from fouling agents and interference from chemicals present in the sample matrix. This article, therefore, investigates the principles of functioning of enzymatic biosensors, their analytical performance over time and the strategies used to optimize their performance. Moreover, the composition of biological fluids as a function of their interaction with biosensing will be presented.

  11. Methods to Enrich Exosomes from Conditioned Media and Biological Fluids.

    Science.gov (United States)

    Sharma, Shayna; Scholz-Romero, Katherin; Rice, Gregory E; Salomon, Carlos

    2018-01-01

    Exosomes are nano-vesicles which can transport a range of molecules including but not limited to proteins and miRNA. This ability of exosomes renders them useful in cellular communication often resulting in biological changes. They have several functions in facilitating normal biological processes such as immune responses and an involvement in pregnancy. However, they have also been linked to pathological conditions including cancer and pregnancy complications such as preeclampsia. An understanding for the role of exosomes in preeclampsia is based on the ability to purify and characterize exosomes. There have been several techniques proposed for the enrichment of exosomes such as ultracentrifugation, density gradient separation, and ultrafiltration although there is no widely accepted optimized technique. Here we describe a workflow for isolating exosomes from cell-conditioned media and biological fluids using a combination of centrifugation, buoyant density, and ultrafiltration approaches.

  12. Fluid Mechanics of Biological Surfaces and their Technological Application

    Science.gov (United States)

    Bechert, D. W.; Bruse, M.; Hage, W.; Meyer, R.

    A survey is given on fluid-dynamic effects caused by the structure and properties of biological surfaces. It is demonstrated that the results of investigations aiming at technological applications can also provide insights into biophysical phenomena. Techniques are described both for reducing wall shear stresses and for controlling boundary-layer separation. (a) Wall shear stress reduction was investigated experimentally for various riblet surfaces including a shark skin replica. The latter consists of 800 plastic model scales with compliant anchoring. Hairy surfaces are also considered, and surfaces in which the no-slip condition is modified. Self-cleaning surfaces such as that of lotus leaves represent an interesting option to avoid fluid-dynamic deterioration by the agglomeration of dirt. An example of technological implementation is discussed for riblets in long-range commercial aircraft. (b) Separation control is also an important issue in biology. After a few brief comments on vortex generators, the mechanism of separation control by bird feathers is described in detail. Self-activated movable flaps (=artificial bird feathers) represent a high-lift system enhancing the maximum lift of airfoils by about 20%. This is achieved without perceivable deleterious effects under cruise conditions. Finally, flight experiments on an aircraft with laminar wing and movable flaps are presented.

  13. Review of Prospects of Biological Fluid Biomarkers in Osteoarthritis.

    Science.gov (United States)

    Nguyen, Lich Thi; Sharma, Ashish Ranjan; Chakraborty, Chiranjib; Saibaba, Balaji; Ahn, Moo-Eob; Lee, Sang-Soo

    2017-03-12

    Osteoarthritis (OA) is a degenerative disease of the joints and is one of the leading causes of disability in adults. However, there are no key therapeutics for OA and medical treatment is based on managing the symptoms and slowing down progression of the disease. Diagnostics based on clinical examination and radiography have provided little information about metabolic changes in joint tissues, disease onset and progression. Due to lack of effective methods for early detection and evaluation of treatment outcome, the measurement of biochemical markers (biomarkers) shows promise as a prospective method aiding in disease monitoring. OA biomarkers that are present in biological fluids such as blood, urine and synovial fluid, sources that are easily isolated from body, are of particular interest. Moreover, there are increasingly more studies identifying and developing new biomarkers for OA. In this review, efforts have been made to summarize the biomarkers that have been reported in recent studies on patients. We also tried to classify biomarkers according to tissue metabolism (bone, cartilage and synovial metabolism markers), pathological pathways (inflammatory and genetic markers) and biological function (chemokines, growth factors, acute phase proteins, etc.).

  14. Fluid models and simulations of biological cell phenomena

    Science.gov (United States)

    Greenspan, H. P.

    1982-01-01

    The dynamics of coated droplets are examined within the context of biofluids. Of specific interest is the manner in which the shape of a droplet, the motion within it as well as that of aggregates of droplets can be controlled by the modulation of surface properties and the extent to which such fluid phenomena are an intrinsic part of cellular processes. From the standpoint of biology, an objective is to elucidate some of the general dynamical features that affect the disposition of an entire cell, cell colonies and tissues. Conventionally averaged field variables of continuum mechanics are used to describe the overall global effects which result from the myriad of small scale molecular interactions. An attempt is made to establish cause and effect relationships from correct dynamical laws of motion rather than by what may have been unnecessary invocation of metabolic or life processes. Several topics are discussed where there are strong analogies droplets and cells including: encapsulated droplets/cell membranes; droplet shape/cell shape; adhesion and spread of a droplet/cell motility and adhesion; and oams and multiphase flows/cell aggregates and tissues. Evidence is presented to show that certain concepts of continuum theory such as suface tension, surface free energy, contact angle, bending moments, etc. are relevant and applicable to the study of cell biology.

  15. Electron probe analysis of biological fluids: Possibilities and limitations

    International Nuclear Information System (INIS)

    Roinel, N.

    1984-01-01

    Physical methods of investigation have become essential to investigations at the cellular or subcellular level. Nuclear magnetic resonance is the most recent and striking example, since it is not only a tool for fundamental physicists and organic chemists, but also an extraordinary powerful imaging tool for physicians. The absorption properties of X rays were used immediately after their discovery to image the bones of skeletons. Later, X rays were also found to be extremely efficient in the measurement of the elemental content of microvolumes irradiated by electron probes. The electron probe analyzer (EPA) was immediately adopted by numerous laboratories of metallurgy, geology, and mineral sciences. In the last fifteen years, since the use of this instrument was suggested for liquid analysis, and a preparative technique was developed, the EPA has been used by an increasing number of biological laboratories for measuring the concentrations of the elements contained in subnanoliter volumes of biological fluids. The so-called microdroplet technique has become a routine laboratory method, the only one able to measure the concentrations of an unlimited number of elements in a single 0.1-nl sample. This explains its use in fields as various as renal, reproductive, digestive, and plant physiology, zoology, etc. Several review papers discuss these applications. The possibilities and limitations of the technique are discussed below

  16. Obstructive renal injury: from fluid mechanics to molecular cell biology

    Directory of Open Access Journals (Sweden)

    Alvaro C Ucero

    2010-04-01

    Full Text Available Alvaro C Ucero1,*, Sara Gonçalves2,*, Alberto Benito-Martin1, Beatriz Santamaría1, Adrian M Ramos1, Sergio Berzal1, Marta Ruiz-Ortega1, Jesus Egido1, Alberto Ortiz11Fundación Jiménez Díaz, Universidad Autónoma de Madrid, Fundación Renal Iñigo Alvarez de Toledo, Madrid, Spain; 2Nefrologia e Transplantação Renal, Hospital de Santa Maria EPE, Lisbon, Portugal *Both authors contributed equally to the manuscriptAbstract: Urinary tract obstruction is a frequent cause of renal impairment. The physiopathology of obstructive nephropathy has long been viewed as a mere mechanical problem. However, recent advances in cell and systems biology have disclosed a complex physiopathology involving a high number of molecular mediators of injury that lead to cellular processes of apoptotic cell death, cell injury leading to inflammation and resultant fibrosis. Functional studies in animal models of ureteral obstruction using a variety of techniques that include genetically modified animals have disclosed an important role for the renin-angiotensin system, transforming growth factor-β1 (TGF-β1 and other mediators of inflammation in this process. In addition, high throughput techniques such as proteomics and transcriptomics have identified potential biomarkers that may guide clinical decision-making.Keywords: urinary tract obstruction, renal injury, fluid mechanics, molecular cell biology

  17. Characterization of Nanoparticle Aggregation in Biologically Relevant Fluids

    Science.gov (United States)

    McEnnis, Kathleen; Lahann, Joerg

    Nanoparticles (NPs) are often studied as drug delivery vehicles, but little is known about their behavior in blood once injected into animal models. If the NPs aggregate in blood, they will be shunted to the liver or spleen instead of reaching the intended target. The use of animals for these experiments is costly and raises ethical questions. Typically dynamic light scattering (DLS) is used to analyze aggregation behavior, but DLS cannot be used because the components of blood also scatter light. As an alternative, a method of analyzing NPs in biologically relevant fluids such as blood plasma has been developed using nanoparticle tracking analysis (NTA) with fluorescent filters. In this work, NTA was used to analyze the aggregation behavior of fluorescent polystyrene NPs with different surface modifications in blood plasma. It was expected that different surface chemistries on the particles will change the aggregation behavior. The effect of the surface modifications was investigated by quantifying the percentage of NPs in aggregates after addition to blood plasma. The use of this characterization method will allow for better understanding of particle behavior in the body, and potential problems, specifically aggregation, can be addressed before investing in in vivo studies.

  18. Heat transfer and fluid flow in biological processes advances and applications

    CERN Document Server

    Becker, Sid

    2015-01-01

    Heat Transfer and Fluid Flow in Biological Processes covers emerging areas in fluid flow and heat transfer relevant to biosystems and medical technology. This book uses an interdisciplinary approach to provide a comprehensive prospective on biofluid mechanics and heat transfer advances and includes reviews of the most recent methods in modeling of flows in biological media, such as CFD. Written by internationally recognized researchers in the field, each chapter provides a strong introductory section that is useful to both readers currently in the field and readers interested in learning more about these areas. Heat Transfer and Fluid Flow in Biological Processes is an indispensable reference for professors, graduate students, professionals, and clinical researchers in the fields of biology, biomedical engineering, chemistry and medicine working on applications of fluid flow, heat transfer, and transport phenomena in biomedical technology. Provides a wide range of biological and clinical applications of fluid...

  19. Wavelet analysis of polarization maps of polycrystalline biological fluids networks

    Science.gov (United States)

    Ushenko, Y. A.

    2011-12-01

    The optical model of human joints synovial fluid is proposed. The statistic (statistic moments), correlation (autocorrelation function) and self-similar (Log-Log dependencies of power spectrum) structure of polarization two-dimensional distributions (polarization maps) of synovial fluid has been analyzed. It has been shown that differentiation of polarization maps of joint synovial fluid with different physiological state samples is expected of scale-discriminative analysis. To mark out of small-scale domain structure of synovial fluid polarization maps, the wavelet analysis has been used. The set of parameters, which characterize statistic, correlation and self-similar structure of wavelet coefficients' distributions of different scales of polarization domains for diagnostics and differentiation of polycrystalline network transformation connected with the pathological processes, has been determined.

  20. Volume and density changes of biological fluids with temperature

    Science.gov (United States)

    Hinghofer-Szalkay, H.

    1985-01-01

    The thermal expansion of human blood, plasma, ultrafiltrate, and erythrocycte concentration at temperatures in the range of 4-48 C is studied. The mechanical oscillator technique which has an accuracy of 1 x 10 to the -5 th g/ml is utilized to measure fluid density. The relationship between thermal expansion, density, and temperature is analyzed. The study reveals that: (1) thermal expansion increases with increasing temperature; (2) the magnitude of the increase declines with increasing temperature; (3) thermal expansion increases with density at temperatures below 40 C; and (4) the thermal expansion of intracellular fluid is greater than that of extracellular fluid in the temperature range of 4-10 C, but it is equal at temperatures greater than or equal to 40 C.

  1. Radioimmunoassay of the myelin basic protein in biological fluids, conditions improving sensitivity and specificity

    International Nuclear Information System (INIS)

    Delassalle, A.; Jacque, C.; Raoul, M.; Legrand, J.C.; Cesselin, F.; Drouet, J.

    1980-01-01

    The radioimmunoassay (RIA) for myelin basic protein (MBP) in biological fluids was reassessed in order to improve its sensitivity and eliminate some interferences. By using the pre-incubation technique and the charcoal-dextram-horse serum mixture for the separation step, the detection limit could be lowered to 200 pg/ml for cerebrospinal fluids (CSF), amniotic fluids (AF) and nervous tissue extracts and 600 pg/ml for sera. The RIA could be used directly on CSF, AF and nervous tissue extracts. Sera, however, had to be heated in citrate buffer at 100 0 C in order to discard interfering material. The present method is 10 to 20 times more sensitive than others previously published. Moreover, it can be applied to amniotic fluid. The biological fluids had to be promptly frozen to avoid degradation of MBP

  2. Detection and differentiation of coxiella burnetii in biological fluids

    Energy Technology Data Exchange (ETDEWEB)

    Frazier, Marvin E. (Richland, WA); Mallavia, Louis P. (Moscow, ID); Samuel, James E. (Derwood, MD); Baca, Oswald G. (Albuquerque, NM)

    1993-01-01

    Methods for detecting the presence of Coxiella burnetii in biological samples, as well as a method for differentiating strains of C. burnetii that are capable of causing acute disease from those strains capable of causing chronic disease are disclosed. The methods generally comprise treating cells contained within the biological sample to expose cellular DNA, and hybridizing the cellular DNA with a DNA probe containing DNA sequences that specifically hybridize with C. burnetii DNA of strains associated with the capacity to cause acute or chronic disease.

  3. Detection and differentiation of coxiella burnetii in biological fluids

    Energy Technology Data Exchange (ETDEWEB)

    Frazier, Marvin E. (Richland, WA); Mallavia, Louis P. (Moscow, ID); Samuel, James E. (Pullman, WA); Baca, Oswald G. (Albuquerque, NM)

    1990-01-01

    Methods for detecting the presence of Coxiella burenetii in biological samples, as well as a method for differentiating strains of C. burnetii that are capable of causing acute disease from those strains capable of causing chronic disease are disclosed. The methods generally comprise treating cells contained within the biological sample to expose cellular DNA, and hybridizing the cellular DNA (specifically rickettsial DNA) with a C. burnetii-specific labeled DNA probe. Radioisotope and biotin labels are preferred, allowing detection through autoradiography and colorimetric assays, respectively.

  4. Detection and differentiation of coxiella burnetii in biological fluids

    Energy Technology Data Exchange (ETDEWEB)

    Frazier, Marvin E. (Richland, WA); Mallavia, Louis P. (Moscow, ID); Baca, Oswald G. (Albuquerque, NM); Samuel, James E. (Pullman, WA)

    1989-01-01

    Methods for detecting the presence of Coxiella burnetii in biological samples, as well as a method for differentiating strains of C. burnetii that are capable of causing acute disease from those strains capable of causing chronic disease are disclosed. The methods generally comprise treating cells contained within the biological sample to expose cellular DNA, and hybridizing the cellular DNA (specifically rickettsial DNA) with a C. burnetii-specific labeled DNA probe. Radioisotope and biotin labels are preferred, allowing detection through autoradiography and colorimetric assays, respectively.

  5. Cystatin C and lactoferrin concentrations in biological fluids as possible prognostic factors in eye tumor development

    Directory of Open Access Journals (Sweden)

    Mariya A. Dikovskaya

    2013-08-01

    Full Text Available Objectives. To investigate the possible role of cystatin C in eye biological fluids locally and in serum and lactoferrin revealing anti-tumor activity in eye tumor development. Background. The increased number of eye tumors was registered recently not only in the countries with high insolation, but also in the northern countries including Russia (11 cases per million of population. Search for new biological markers is important for diagnosis and prognosis in eye tumors. Cystatin C, an endogenous inhibitor of cysteine proteases, plays an important protective role in several tumors. Lactoferrin was shown to express anti-tumor and antiviral activities. It was hypothesized that cystatin C and lactoferrin could serve as possible biomarkers in the diagnosis of malignant and benign eye tumors. Study design. A total of 54 patients with choroidal melanoma and benign eye tumors were examined (part of them undergoing surgical treatment. Serum, tear fluid and intraocular fluid samples obtained from the anterior chamber of eyes in patients with choroidal melanoma were studied. Methods. Cystatin C concentration in serum and eye biological fluids was measured by commercial ELISA kits for human (BioVendor, Czechia; lactoferrin concentration – by Lactoferrin-strip D 4106 ELISA test systems (Vector-BEST, Novosibirsk Region, Russia. Results. Cystatin C concentration in serum of healthy persons was significantly higher as compared to tear and intraocular fluids. In patients with choroidal melanoma, increased cystatin C concentration was similar in tear fluid of both the eyes. Lactoferrin level in tear fluid of healthy persons was significantly higher than its serum level. Significantly increased lactoferrin concentration in tear fluid was noted in patients with benign and malignant eye tumors. Conclusion. Increased level of cystatin C in tear fluid seems to be a possible diagnostic factor in the eye tumors studied. However, it does not allow us to differentiate

  6. Cannabinoid Markers in Biological Fluids and Tissues: Revealing Intake.

    Science.gov (United States)

    Huestis, Marilyn A; Smith, Michael L

    2018-02-01

    Understanding cannabis and synthetic cannabinoid intake history is vital for treating drug dependence, investigating cannabinoid effects, and providing information to healthcare personnel, medical examiners, and public health officials; this is particularly relevant today with cannabis medicalization and legalization. Required information includes identifying exposure, time of use, frequency of use, relapse, withdrawal, and predicting cannabinoid effects. Recent controlled cannabinoid administration studies enable the development of models and markers to better identify patterns of intake and exposure. Future challenges include developing behavioral markers of cannabis impairment, bringing to market breathalyzers for cannabinoid detection, and identifying markers of recent cannabis intake in diverse biological matrices. We posit that biological monitoring of cannabinoids and metabolites will improve the characterization of cannabis and synthetic cannabinoid intake history. Copyright © 2017 Elsevier Ltd. All rights reserved.

  7. The characterization of exosomes from biological fluids of patients with different types of cancer

    Science.gov (United States)

    Yunusova, N. V.; Tamkovich, S. N.; Stakheeva, M. N.; Grigor'eva, A. A.; Somov, A. K.; Tugutova, E. A.; Kolomiets, L. A.; Molchanov, S. V.; Afanas'ev, S. G.; Kakurina, G. V.; Choinzonov, E. L.; Kondakova, I. V.

    2017-09-01

    Exosomes are extracellular membrane structures involved in many physiological and pathological processes including cancerogenesis and metastasis. The purpose of the study was to isolate, identify and analyze the total content of exosomes in biological fluids. The exosomes from the plasma and ascites samples of the patients with ovarian cancer, from the blood plasma of the patients with colorectal and head and neck squamous cell cancer as well as from the blood plasma of healthy donors were characterized using transmission electron microscopy and flow cytometry. The subpopulations of the exosomes in the biological fluids of the patients with different types of cancer were similar, but the protein concentrations of exosomes were different. In this paper we present the methodological approaches allowing us to obtain high quality exosome preparations from biological fluids.

  8. Method for detection of a suspect viral deoxyribonucleic acid in an acellular biological fluid

    International Nuclear Information System (INIS)

    Berninger, M.S.

    1982-01-01

    A method for evaluating an acellular biological fluid for the presence of a suspect viral DNA, such as DNA of the Hepatitis-B virus, is described. The acellular biological fluid is treated to immobilize in denatured form the DNAs including the suspect viral DNA on a solid substrate. This substrate is contacted with a solution including radioisotopically-labelled suspect viral denatured DNA to renature the immobilized suspect viral native DNA. The solid substrate is then evaluated for radioisotopically-labelled suspect viral renatured DNA. (author)

  9. Separation methods for captopril in pharmaceuticals and biological fluids.

    Science.gov (United States)

    Mansour, Fotouh R; Danielson, Neil D

    2012-06-01

    Captopril (CAP) is an orally active angiotensin-converting enzyme (ACE) inhibitor and has been widely used for management of hypertension and congestive heart failure. CAP lacks an aromatic chromophore required for facile direct UV detection and also has two chiral centers. These factors can render the determination of CAP in complex matrices challenging. This review covers more than 20 years of analytical research on this drug, focusing mainly on pharmaceutical and biological applications. The primary separation techniques discussed are gas chromatography, liquid chromatography, and capillary electrophoresis. The structures of the CAP derivatizing agents as well as a table summarizing various HPLC methods are provided. A discussion of key recent chromatographic and electrophoretic methods for other ACE inhibitors is also present. © 2012 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  10. Determination of drugs in biological fluids by direct injection of samples for liquid-chromatographic analysis.

    Science.gov (United States)

    Mullett, Wayne M

    2007-03-10

    The analysis of drugs in various biological fluids is an important criterion for the determination of the physiological performance of a drug. After sampling of the biological fluid, the next step in the analytical process is sample preparation. The complexity of biological fluids adds to the challenge of direct determination of the drug by chromatographic analysis, therefore demanding a sample preparation step that is often time-consuming, tedious, and frequently overlooked. However, direct on-line injection methods offer the advantage of reducing sample preparation steps and enabling effective pre-concentration and clean-up of biological fluids. These procedures can be automated and therefore reduce the requirements for handling potentially infectious biomaterial, improve reproducibility, and minimize sample manipulations and potential contamination. The objective of this review is to present an overview of the existing literature with emphasis on advances in automated sample preparation methods for liquid-chromatographic methods. More specifically, this review concentrates on the use of direct injection techniques, such as restricted-access materials, turbulent-flow chromatography and other automated on-line solid-phase extraction (SPE) procedures. It also includes short overviews of emerging automated extraction-phase technologies, such as molecularly imprinted polymers, in-tube solid-phase micro-extraction, and micro-extraction in a packed syringe for a more selective extraction of analytes from complex samples, providing further improvements in the analysis of biological materials. Lastly, the outlook for these methods and potential new applications for these technologies are briefly discussed.

  11. Integrating fluid dynamic and biologic effects on staphylococci bacteria biofilms

    Science.gov (United States)

    Sherman, Erica; Endres, Jennifer; Bayles, Kenneth; Wei, Timothy

    2017-11-01

    Staphylococcus aureus bacteria are able to form biofilms and distinctive tower structures that facilitate their ability to tolerate treatment and to spread within the human body. The formation of towers, which break off, get carried downstream and serve to initiate biofilms in other parts of the body are of particular interest here. In previous work on biofilm growth and evolution in steady, laminar microchannel flows, it has been established that tower formation occurs around a very limited range of applied shear stresses centered on 0.6 dynes/cm2. Quantifying cell density characteristics as a function of time during biofilm formation reveals indicators of tower development hours before towers actually form and become visible. The next step in this research is to explore biological factors that might explain why this specific shear is so important. Additional studies with mutants, e.g. ica-A, that have been tied to tower formation have been conducted. The shear dependence of these mutants and their correlation to the behavior of wild type S. aureus is examined.

  12. Drug screening in biological fluids - The need for a systematic approach

    NARCIS (Netherlands)

    de Zeeuw, R.A

    1997-01-01

    In this paper the key steps towards drug screening in biological fluids are considered: (i) sample work up-isolation-concentration: (ii) differentiation-detection; (iii) identification. For (i) solid-phase extraction has very good potential; for (ii) thin-layer chromatography, gas chromatography and

  13. Evaluation and Correction for Optical Scattering Variations in Laser Speckle Rheology of Biological Fluids

    Science.gov (United States)

    Hajjarian, Zeinab; Nadkarni, Seemantini K.

    2013-01-01

    Biological fluids fulfill key functionalities such as hydrating, protecting, and nourishing cells and tissues in various organ systems. They are capable of these versatile tasks owing to their distinct structural and viscoelastic properties. Characterizing the viscoelastic properties of bio-fluids is of pivotal importance for monitoring the development of certain pathologies as well as engineering synthetic replacements. Laser Speckle Rheology (LSR) is a novel optical technology that enables mechanical evaluation of tissue. In LSR, a coherent laser beam illuminates the tissue and temporal speckle intensity fluctuations are analyzed to evaluate mechanical properties. The rate of temporal speckle fluctuations is, however, influenced by both optical and mechanical properties of tissue. Therefore, in this paper, we develop and validate an approach to estimate and compensate for the contributions of light scattering to speckle dynamics and demonstrate the capability of LSR for the accurate extraction of viscoelastic moduli in phantom samples and biological fluids of varying optical and mechanical properties. PMID:23705028

  14. Banking of biological fluids for studies of disease-associated protein biomarkers

    DEFF Research Database (Denmark)

    Rasmussen, Anne-Sofie Schrohl; Würtz, Sidse Ørnbjerg; Kohn, Elise

    2008-01-01

    With the increasing demand of providing personalized medicine the need for biobanking of biological material from individual patients has increased. Such samples are essential for molecular research aimed at characterizing diseases at several levels ranging from epidemiology and diagnostic...... and as a surrogate response marker. Many types of biological fluids or tissues can be collected and stored in biorepositories. Samples of blood can be further processed into plasma and serum, and tissue pieces can be either frozen or fixed in formalin and then embedded into paraffin. The present review focuses...... on biological fluids, especially serum and plasma, intended for study of protein biomarkers. In biomarker studies the process from the decision to take a sample from an individual to the moment the sample is safely placed in the biobank consists of several phases including collection of samples, transport...

  15. Tribological performance of the biological components of synovial fluid in artificial joint implants

    Science.gov (United States)

    Ghosh, Subir; Choudhury, Dipankar; Roy, Taposh; Moradi, Ali; Masjuki, H H; Pingguan-Murphy, Belinda

    2015-01-01

    The concentration of biological components of synovial fluid (such as albumin, globulin, hyaluronic acid, and lubricin) varies between healthy persons and osteoarthritis (OA) patients. The aim of the present study is to compare the effects of such variation on tribological performance in a simulated hip joint model. The study was carried out experimentally by utilizing a pin-on-disk simulator on ceramic-on-ceramic (CoC) and ceramic-on-polyethylene (CoP) hip joint implants. The experimental results show that both friction and wear of artificial joints fluctuate with the concentration level of biological components. Moreover, the performance also varies between material combinations. Wear debris sizes and shapes produced by ceramic and polyethylene were diverse. We conclude that the biological components of synovial fluid and their concentrations should be considered in order to select an artificial hip joint to best suit that patient. PMID:27877822

  16. Mapping of polycrystalline films of biological fluids utilizing the Jones-matrix formalism

    Science.gov (United States)

    Ushenko, Vladimir A.; Dubolazov, Alexander V.; Pidkamin, Leonid Y.; Sakchnovsky, Michael Yu; Bodnar, Anna B.; Ushenko, Yuriy A.; Ushenko, Alexander G.; Bykov, Alexander; Meglinski, Igor

    2018-02-01

    Utilizing a polarized light approach, we reconstruct the spatial distribution of birefringence and optical activity in polycrystalline films of biological fluids. The Jones-matrix formalism is used for an accessible quantitative description of these types of optical anisotropy. We demonstrate that differentiation of polycrystalline films of biological fluids can be performed based on a statistical analysis of the distribution of rotation angles and phase shifts associated with the optical activity and birefringence, respectively. Finally, practical operational characteristics, such as sensitivity, specificity and accuracy of the Jones-matrix reconstruction of optical anisotropy, were identified with special emphasis on biomedical application, specifically for differentiation of bile films taken from healthy donors and from patients with cholelithiasis.

  17. Radioenzymatic microassay for picogram quantities of serotonin or acetylserotonin in biological fluids and tissues

    International Nuclear Information System (INIS)

    Hussain, M.N.; Benedict, C.R.

    1987-01-01

    This paper describes several modifications of the original radioenzymatic assay for serotonin which increase the sensitivity of the assay 20-fold as well as enhance its reliability. Using this method serotonin concentrations can be directly measured in biological examples without precleaning the sample. When compared to currently available methods this assay is specific and sensitive to approximately 1 pg of serotonin and can be used to measure serotonin levels in individual brain nuclei or microliter quantities of biological fluids. This assay can be easily adapted for the direct measurement of N-acetylserotonin. A large number of samples can be assayed in a single working day

  18. Application of LC–MS/MS for quantitative analysis of glucocorticoids and stimulants in biological fluids

    OpenAIRE

    Haneef, Jamshed; Shaharyar, Mohammad; Husain, Asif; Rashid, Mohd; Mishra, Ravinesh; Parveen, Shama; Ahmed, Niyaz; Pal, Manoj; Kumar, Deepak

    2013-01-01

    Liquid chromatography tandem mass chromatography (LCâMS/MS) is an important hyphenated technique for quantitative analysis of drugs in biological fluids. Because of high sensitivity and selectivity, LCâMS/MS has been used for pharmacokinetic studies, metabolites identification in the plasma and urine. This manuscript gives comprehensive analytical review, focusing on chromatographic separation approaches (column packing materials, column length and mobile phase) as well as different acquisiti...

  19. Application of LC–MS/MS for quantitative analysis of glucocorticoids and stimulants in biological fluids

    OpenAIRE

    Haneef, Jamshed; Shaharyar, Mohammad; Husain, Asif; Rashid, Mohd; Mishra, Ravinesh; Parveen, Shama; Ahmed, Niyaz; Pal, Manoj; Kumar, Deepak

    2013-01-01

    Liquid chromatography tandem mass chromatography (LC–MS/MS) is an important hyphenated technique for quantitative analysis of drugs in biological fluids. Because of high sensitivity and selectivity, LC–MS/MS has been used for pharmacokinetic studies, metabolites identification in the plasma and urine. This manuscript gives comprehensive analytical review, focusing on chromatographic separation approaches (column packing materials, column length and mobile phase) as well as different acquisiti...

  20. Isolation and characterization of exosomes from cell culture supernatants and biological fluids

    OpenAIRE

    Théry, Clotilde; Amigorena, Sebastian; Raposo, Graça; Clayton, Aled

    2006-01-01

    Exosomes are small membrane vesicles found in cell culture supernatants and in different biological fluids. Exosomes form in a particular population of endosomes, called multivesicular bodies (MVBs), by inward budding into the lumen of the compartment. Upon fusion of MVBs with the plasma membrane, these internal vesicles are secreted. Exosomes possess a defined set of membrane and cytosolic proteins. The physiological function of exosomes is still a matter of debate, but increasing results in...

  1. Mechanisms and models of the dehydration self-organization in biological fluids

    International Nuclear Information System (INIS)

    Tarasevich, Yurii Yu

    2004-01-01

    The dehydration self-organization phenomenon in biological fluids attracted the attention of researchers slightly more than a decade ago. While seemingly simple (the structure formation is possible to observe even in domestic conditions), the effect turned out to be extremely complicated and to involve a number of interrelated processes of a different physical nature. The dehydration self-organization effect in biological fluids underlies a medical diagnostic technique patented in 40 countries of the world, while the mechanisms that underlie the technique still remain largely obscure. This review is an attempt to draw an integrated picture of the current state of the problem: to emphasize reliably established facts and the problems that remain to be solved, to put an end to speculation, and to characterize the available theories and models. An analysis of the literature sources allows us to draw the conclusion that the effects observed in the dehydration of biological fluids are typical for colloidal solutions in general and can be described in the framework of conventional physical approaches. (from the current literature)

  2. Bions: A Family of Biomimetic Mineralo-Organic Complexes Derived from Biological Fluids

    Science.gov (United States)

    Martel, Jan; Young, John D.

    2013-01-01

    Mineralo-organic nanoparticles form spontaneously in human body fluids when the concentrations of calcium and phosphate ions exceed saturation. We have shown previously that these mineralo-organic nanoparticles possess biomimetic properties and can reproduce the whole phenomenology of the so-called nanobacteria—mineralized entities initially described as the smallest microorganisms on earth. Here, we examine the possibility that various charged elements and ions may form mineral nanoparticles with similar properties in biological fluids. Remarkably, all the elements tested, including sodium, magnesium, aluminum, calcium, manganese, iron, cobalt, nickel, copper, zinc, strontium, and barium form mineralo-organic particles with bacteria-like morphologies and other complex shapes following precipitation with phosphate in body fluids. Upon formation, these mineralo-organic particles, which we term bions, invariably accumulate carbonate apatite during incubation in biological fluids; yet, the particles also incorporate additional elements and thus reflect the ionic milieu in which they form. Bions initially harbor an amorphous mineral phase that gradually converts to crystals in culture. Our results show that serum produces a dual inhibition-seeding effect on bion formation. Using a comprehensive proteomic analysis, we identify a wide range of proteins that bind to these mineral particles during incubation in medium containing serum. The two main binding proteins identified, albumin and fetuin-A, act as both inhibitors and seeders of bions in culture. Notably, bions possess several biomimetic properties, including the possibility to increase in size and number and to be sub-cultured in fresh culture medium. Based on these results, we propose that bions represent biological, mineralo-organic particles that may form in the body under both physiological and pathological homeostasis conditions. These mineralo-organic particles may be part of a physiological cycle that

  3. Bions: a family of biomimetic mineralo-organic complexes derived from biological fluids.

    Directory of Open Access Journals (Sweden)

    Cheng-Yeu Wu

    Full Text Available Mineralo-organic nanoparticles form spontaneously in human body fluids when the concentrations of calcium and phosphate ions exceed saturation. We have shown previously that these mineralo-organic nanoparticles possess biomimetic properties and can reproduce the whole phenomenology of the so-called nanobacteria-mineralized entities initially described as the smallest microorganisms on earth. Here, we examine the possibility that various charged elements and ions may form mineral nanoparticles with similar properties in biological fluids. Remarkably, all the elements tested, including sodium, magnesium, aluminum, calcium, manganese, iron, cobalt, nickel, copper, zinc, strontium, and barium form mineralo-organic particles with bacteria-like morphologies and other complex shapes following precipitation with phosphate in body fluids. Upon formation, these mineralo-organic particles, which we term bions, invariably accumulate carbonate apatite during incubation in biological fluids; yet, the particles also incorporate additional elements and thus reflect the ionic milieu in which they form. Bions initially harbor an amorphous mineral phase that gradually converts to crystals in culture. Our results show that serum produces a dual inhibition-seeding effect on bion formation. Using a comprehensive proteomic analysis, we identify a wide range of proteins that bind to these mineral particles during incubation in medium containing serum. The two main binding proteins identified, albumin and fetuin-A, act as both inhibitors and seeders of bions in culture. Notably, bions possess several biomimetic properties, including the possibility to increase in size and number and to be sub-cultured in fresh culture medium. Based on these results, we propose that bions represent biological, mineralo-organic particles that may form in the body under both physiological and pathological homeostasis conditions. These mineralo-organic particles may be part of a

  4. Bions: a family of biomimetic mineralo-organic complexes derived from biological fluids.

    Science.gov (United States)

    Wu, Cheng-Yeu; Young, Lena; Young, David; Martel, Jan; Young, John D

    2013-01-01

    Mineralo-organic nanoparticles form spontaneously in human body fluids when the concentrations of calcium and phosphate ions exceed saturation. We have shown previously that these mineralo-organic nanoparticles possess biomimetic properties and can reproduce the whole phenomenology of the so-called nanobacteria-mineralized entities initially described as the smallest microorganisms on earth. Here, we examine the possibility that various charged elements and ions may form mineral nanoparticles with similar properties in biological fluids. Remarkably, all the elements tested, including sodium, magnesium, aluminum, calcium, manganese, iron, cobalt, nickel, copper, zinc, strontium, and barium form mineralo-organic particles with bacteria-like morphologies and other complex shapes following precipitation with phosphate in body fluids. Upon formation, these mineralo-organic particles, which we term bions, invariably accumulate carbonate apatite during incubation in biological fluids; yet, the particles also incorporate additional elements and thus reflect the ionic milieu in which they form. Bions initially harbor an amorphous mineral phase that gradually converts to crystals in culture. Our results show that serum produces a dual inhibition-seeding effect on bion formation. Using a comprehensive proteomic analysis, we identify a wide range of proteins that bind to these mineral particles during incubation in medium containing serum. The two main binding proteins identified, albumin and fetuin-A, act as both inhibitors and seeders of bions in culture. Notably, bions possess several biomimetic properties, including the possibility to increase in size and number and to be sub-cultured in fresh culture medium. Based on these results, we propose that bions represent biological, mineralo-organic particles that may form in the body under both physiological and pathological homeostasis conditions. These mineralo-organic particles may be part of a physiological cycle that

  5. Enzyme Biosensors for Biomedical Applications: Strategies for Safeguarding Analytical Performances in Biological Fluids

    Science.gov (United States)

    Rocchitta, Gaia; Spanu, Angela; Babudieri, Sergio; Latte, Gavinella; Madeddu, Giordano; Galleri, Grazia; Nuvoli, Susanna; Bagella, Paola; Demartis, Maria Ilaria; Fiore, Vito; Manetti, Roberto; Serra, Pier Andrea

    2016-01-01

    Enzyme-based chemical biosensors are based on biological recognition. In order to operate, the enzymes must be available to catalyze a specific biochemical reaction and be stable under the normal operating conditions of the biosensor. Design of biosensors is based on knowledge about the target analyte, as well as the complexity of the matrix in which the analyte has to be quantified. This article reviews the problems resulting from the interaction of enzyme-based amperometric biosensors with complex biological matrices containing the target analyte(s). One of the most challenging disadvantages of amperometric enzyme-based biosensor detection is signal reduction from fouling agents and interference from chemicals present in the sample matrix. This article, therefore, investigates the principles of functioning of enzymatic biosensors, their analytical performance over time and the strategies used to optimize their performance. Moreover, the composition of biological fluids as a function of their interaction with biosensing will be presented. PMID:27249001

  6. Influence of biological fluids in bacterial viability on different hospital surfaces and fomites.

    Science.gov (United States)

    Esteves, Deigilam C; Pereira, Valeria C; Souza, Joyce M; Keller, Rogéria; Simões, Rebeca D; Winkelstroter Eller, Lizziane K; Rodrigues, Marcus Vinicius P

    2016-03-01

    The hospital environment is susceptible to bacterial contamination along with survival in fomites and surfaces, allowing dissemination of potential pathogenic strains. The present research aimed to evaluate the influence of biological fluids in bacterial viability on fomites and surfaces commonly present in nosocomial environment. Four different fomites and surfaces (ceramic floor, cotton fabric fragments and synthetic fibers, and eggcrate foam mattress) were contaminated with potential pathogens (Staphylococcus aureus, Escherichia coli, Enterococcus faecalis, Pseudomonas aeruginosa, and Klebsiella pneumoniae), then submitted to influence of biological fluids (blood, urine, artificial saliva). The viability of strains was evaluated at 24 hours after contamination and then in intervals of 7 days, by the colony-forming unit count technique. S aureus presented viability (>70 days) in all conditions tested, E faecalis and K pneumoniae had decreased viability over time, and E coli did not exhibit a growth relationship with surfaces or fluids. Persistence and adaptability capacity of potential pathogens in fomites and surfaces exposed to the patient are important for guidance, planning, and outlining of protocols for microorganism dissemination control and prevention in the health care environment. Copyright © 2016 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Elsevier Inc. All rights reserved.

  7. Quantitative analysis of biological fluids by electron probe and X ray spectrometry

    International Nuclear Information System (INIS)

    Girod, Chantal

    1986-01-01

    In order to know the kidney normal operation and to have an insight on cellular transport mechanisms and hormonal regulations at the nephron level, a technique based on the use of an electron probe has been developed for the elemental analysis of micro-volumes of biological fluids. This academic document reports applications of this technique on animals on which such fluids have been sampled at different levels of the nephron. As these samples are available in too small volumes to be dosed by conventional methods, they have been quantitatively analysed by using an electronic probe based analyser in order to determine concentrations of all elements with an atomic number greater than that of carbon. After a presentation of the implemented method and hardware, the author thus describes how an analysis is performed, and reports and discusses an example (analysis conditions, data acquisition, data processing, minimum detectable concentration, reasons for measurement scattering)

  8. A radioimmunoassay for the detection of diethylstilboestrol and related stilbenes in biological fluids

    International Nuclear Information System (INIS)

    Hallahan, Cornelius; McGarry, Yvonne; Collins, J.D.

    1985-01-01

    A radioimmunoassay for the measurement of the synthetic anabolic agent diethylstilboestrol (DES) is described. It is based on a commercially available antiserum and a tritiated derivative of DES. The method can detect low concentrations of residues (less than 0.5 ng/ml) in small samples (0.05 to 0.2 ml) of biological fluids. DES was measured in plasma, bile and urine obtained from a calf slaughtered 22 days after subcutaneous implantation of 24 mg DES. The assay described is suitable as a rapid screening procedure for identifying animals treated with stilbene substances. (author)

  9. Headspace solid-phase microextraction procedures for gas chromatographic analysis of biological fluids and materials.

    Science.gov (United States)

    Mills, G A; Walker, V

    2000-12-01

    Solid-phase microextraction (SPME) is a new solventless sample preparation technique that is finding wide usage. This review provides updated information on headspace SPME with gas chromatographic separation for the extraction and measurement of volatile and semivolatile analytes in biological fluids and materials. Firstly the background to the technique is given in terms of apparatus, fibres used, extraction conditions and derivatisation procedures. Then the different matrices, urine, blood, faeces, breast milk, hair, breath and saliva are considered separately. For each, methods appropriate for the analysis of drugs and metabolites, solvents and chemicals, anaesthetics, pesticides, organometallics and endogenous compounds are reviewed and the main experimental conditions outlined with specific examples. Then finally, the future potential of SPME for the analysis of biological samples in terms of the development of new devices and fibre chemistries and its coupling with high-performance liquid chromatography is discussed.

  10. Analysis of antiepileptic drugs in biological fluids by means of electrokinetic chromatography.

    Science.gov (United States)

    Pucci, Vincenzo; Raggi, Maria Augusta

    2005-02-01

    An overview of the electrokinetic chromatographic methods for the analysis of antiepileptic drug levels in biological samples is presented. In particular, micellar electrokinetic capillary chromatography is a very suitable method for the determination of these drugs, because it allows a rapid, selective, and accurate analysis. In addition to the electrokinetic chromatographic studies on the determination of antiepileptic drugs, some information regarding sample pretreatment will also be reported: this is a critical step when the analysis of biological fluids is concerned. The electrokinetic chromatographic methods for the determination of recent antiepileptic drugs (e.g., lamotrigine, levetiracetam) and classical anticonvulsants (e.g., carbamazepine, phenytoin, ethosuximide, valproic acid) will be discussed in depth, and their pharmacological profiles will be briefly described as well.

  11. Simulation of biological flow and transport in complex geometries using embedded boundary/volume-of-fluid methods

    International Nuclear Information System (INIS)

    Trebotich, David

    2007-01-01

    We have developed a simulation capability to model multiscale flow and transport in complex biological systems based on algorithms and software infrastructure developed under the SciDAC APDEC CET. The foundation of this work is a new hybrid fluid-particle method for modeling polymer fluids in irregular microscale geometries that enables long-time simulation of validation experiments. Both continuum viscoelastic and discrete particle representations have been used to model the constitutive behavior of polymer fluids. Complex flow environment geometries are represented on Cartesian grids using an implicit function. Direct simulation of flow in the irregular geometry is then possible using embedded boundary/volume-of-fluid methods without loss of geometric detail. This capability has been used to simulate biological flows in a variety of application geometries including biomedical microdevices, anatomical structures and porous media

  12. Analytical Methods for the Determination of Rosuvastatin in Pharmaceutical Formulations and Biological Fluids: A Critical Review.

    Science.gov (United States)

    Ângelo, Marilene Lopes; Moreira, Fernanda de Lima; Morais Ruela, André Luís; Santos, Ana Laura Araújo; Salgado, Hérida Regina Nunes; de Araújo, Magali Benjamim

    2018-07-04

    Rosuvastatin calcium (ROS), ( Figure 1 ) belongs to the "statins" group, which is the 3-hydroxy-3-methylglutaryl coenzyme A (HMG-CoA) reductase inhibitor. This drug is indicated for dyslipidemias treatment and can help to decrease the level of "bad cholesterol" and can consequently reduce the development of atherosclerosis and the risk of heart diseases. ROS was developed by Astra-Zeneca and it was approved in 2003 by the FDA in the United States. In 2015, under the trade name Crestor®, it was the fourth largest selling drug in the United States with sales above $5 billion. This study presents a literature review of analytical methods for the quantification of ROS in pharmaceutical preparations and biological fluids. The major analytical methods described in this study for ROS were spectrophotometry, high-performance liquid chromatography (HPLC) coupled to ultraviolet (UV) detection, and tandem mass spectrometry (LC-MS/MS).

  13. Use of self-actuating and self-sensing cantilevers for imaging biological samples in fluid.

    Science.gov (United States)

    Fantner, G E; Schumann, W; Barbero, R J; Deutschinger, A; Todorov, V; Gray, D S; Belcher, A M; Rangelow, I W; Youcef-Toumi, K

    2009-10-28

    In this paper, we present a detailed investigation into the suitability of atomic force microscopy (AFM) cantilevers with integrated deflection sensor and micro-actuator for imaging of soft biological samples in fluid. The Si cantilevers are actuated using a micro-heater at the bottom end of the cantilever. Sensing is achieved through p-doped resistors connected in a Wheatstone bridge. We investigated the influence of the water on the cantilever dynamics, the actuation and the sensing mechanisms, as well as the crosstalk between sensing and actuation. Successful imaging of yeast cells in water using the integrated sensor and actuator shows the potential of the combination of this actuation and sensing method. This constitutes a major step towards the automation and miniaturization required to establish AFM in routine biomedical diagnostics and in vivo applications.

  14. Analysis of volatile metabolites in biological fluids as indicators of prodromal disease condition

    Science.gov (United States)

    Zlatkis, A.

    1982-01-01

    The volatile profile cannot be defined as a single class of substances, rather it is a broad spectrum of materials of different polarities characterized by having a boiling-point in the low to medium range (up to approximately 300 C) and the fact that the compounds are suitable for gas chromatography without derivatization. The organic volatile profiles are very complex mixtures of metabolic byproducts, intermediates, and terminal products of enzymatic degradations composed mainly of alcohols, ketones, aldehydes, pyrazines, sulfides, isothiocyanates, pyrroles, and furans. The concentration of organic volatiles in biological fluids covers a wide range with many important components present at trace levels. The complexity of the organic volatile fraction requires the use of capillary columns for their separation.

  15. Determination of drugs in biological fluids by high-performance liquid chromatography with on-line sample processing.

    Science.gov (United States)

    Oertel, R; Richter, K; Gramatté, T; Kirch, W

    1998-02-27

    An automated two column HPLC system with the new packing material LiChrospher RP-18 ADS (alkyl-diol-silica) was tested for the determination of several drugs and metabolites (talinolol, celiprolol, metoprolol, oxprenolol, triamterene, trimethoprim, tiracizine, articaine, detajmium, ajmaline, lamotrigine) in various biological fluids (serum, urine, intestinal aspirates, supernatants of cell cultures and supernatants after protein denaturation). The method allows the direct injection of biological fluids into a reversed-phase HPLC system and on-line clean-up and sample enrichment by a column-switching technique. Precision, accuracy and sensitivity were similar to conventional assays as described in the literature. With this new method it was possible to measure drug concentrations in various biological fluids without changing the sample preparation procedure. In some cases an additional sample preparation like protein denaturation or solid-phase extraction was advantageous to enhance the sensitivity of the method and the life-time of the ADS column.

  16. Physics of non-Newtonian fluids and interdisciplinary relations (biology and criminology)

    Science.gov (United States)

    Holubova, R.

    2018-03-01

    The aim of the paper is the presentation of an interdisciplinary topic that allows applying content knowledge in physics, mathematics and biology in real life environment. Students use to play games and view crime scenes but in common they have little knowledge about the science used during crime scene investigation. In this paper the science background of blood spatter analysis is presented—the physics of non-Newtonian fluids, the biology of blood and mathematics—the measurement and calculation of the angle of inpact, the relationship between height and spatter diameter. This topic was choosen according to the analysis of interviews with secondary and high school learners realized at four schools in Moravia, Czech Republic. The topic can be taught at secondary schools so as at a higher level at high schools. Hands-on activities are included. The teaching strategy supports group work. The appropriateness and reasonableness of the topic was checked in the real teaching process and the activities have had a positive feedback.

  17. Protocol for quality control in metabolic profiling of biological fluids by U(H)PLC-MS.

    Science.gov (United States)

    Gika, Helen G; Zisi, Chrysostomi; Theodoridis, Georgios; Wilson, Ian D

    2016-01-01

    The process of untargeted metabolic profiling/phenotyping of complex biological matrices, i.e., biological fluids such as blood plasma/serum, saliva, bile, and tissue extracts, provides the analyst with a wide range of challenges. Not the least of these challenges is demonstrating that the acquired data are of "good" quality and provide the basis for more detailed multivariate, and other, statistical analysis necessary to detect, and identify, potential biomarkers that might provide insight into the process under study. Here straightforward and pragmatic "quality control (QC)" procedures are described that allow investigators to monitor the analytical processes employed for global, untargeted, metabolic profiling. The use of this methodology is illustrated with an example from the analysis of human urine where an excel spreadsheet of the preprocessed LC-MS output is provided with embedded macros, calculations and visualization plots that can be used to explore the data. Whilst the use of these procedures is exemplified on human urine samples, this protocol is generally applicable to metabonomic/metabolomic profiling of biofluids, tissue and cell extracts from many sources. Copyright © 2015 Elsevier B.V. All rights reserved.

  18. Sample preparation for liquid chromatographic analysis of phytochemicals in biological fluids.

    Science.gov (United States)

    Oh, Ju-Hee; Lee, Young-Joo

    2014-01-01

    Natural products have been used traditionally for the treatment and prevention of diseases for thousands of years and are nowadays consumed as dietary supplements and herbal medicine. To ensure the safe and effective use of these herbal products, information about bioavailability of active compounds in plasma or target tissues should be provided via validated analytical methods combined with appropriate sampling methods. To provide comprehensive and abridged information about sample preparation methods for the quantification of phytochemicals in biological samples using liquid chromatography analysis. Sample pre-treatment procedures used in analytical methods for in vivo pharmacokinetic studies of natural compounds or herbal medicines were reviewed. These were categorised according to the biological matrices (plasma, bile, urine, faeces and tissues) and sample clean-up processes (protein precipitation, liquid-liquid extraction and solid-phase extraction). Although various kinds of sample pre-treatment methods have been developed, liquid-liquid extraction is still widely used and solid-phase extraction is becoming increasingly popular because of its efficiency for extensive clean up of complex matrix samples. However, protein precipitation is still favoured due to its simplicity. Sample treatment for phytochemical analysis in biological fluids is an indispensable and critical step to obtain high quality results. This step could dominate the overall analytical process because both the duration of the process as well as the reliability of the data depend in large part on its efficiency. Thus, special attention should be given to the choice of a proper sample treatment method that targets analytes and their biomatrix. Copyright © 2013 John Wiley & Sons, Ltd.

  19. A luminescent metal organic framework with high sensitivity for detecting and removing copper ions from simulated biological fluids.

    Science.gov (United States)

    Zheng, Tian-Tian; Zhao, Jiao; Fang, Zhou-Wen; Li, Meng-Ting; Sun, Chun-Yi; Li, Xiao; Wang, Xin-Long; Su, Zhong-Min

    2017-02-21

    The crystal structure of Cd-MOF-74 was obtained for the first time that possesses high sensitivity for the detection of copper ions from water and simulated biological fluids based on changes in luminescent intensity. Furthermore, Cd-MOF-74 could selectively remove Cu 2+ from simulated biological fluids that contain Mg 2+ , Co 2+ , Zn 2+ , Fe 2+ , Ni 2+ , Na + , and K + . The adsorption capacity of this adsorbent for copper ions reached 189.5 mg g -1 and it quickly adsorbed copper ions within 10 minutes under 10 ppm Cu 2+ in the simulated biological system. XPS, PXRD, and gas adsorption measurements revealed that this high sensitivity and selectivity of Cd-MOF-74 resulted from the partial substitution of Cd 2+ by Cu 2+ in the framework. Although many MOF materials have been employed for sensor or selective adsorption of Cu 2+ , Cd-MOF-74 is the first example of MOFs showing both capabilities in simulated biological fluids, which represents a pioneering work that extends the applications of MOF materials in the biological field.

  20. Evaluation of the solubility of the HPMC: PVA blends in biological fluids in vitro

    Directory of Open Access Journals (Sweden)

    Sara Elis Bianchi

    2011-01-01

    Full Text Available Polymers are often used to coat tablets for controlled drug release. The purpose of this study is to evaluate the solubility of the HPMC and PVA blend compared to isolated polymers in solutions with a pH of biological fluids (6 and 1.2 and the dissolution of capsules obtained using theophylline granules produced with the HPMC/PVA 25/75 blend as a matrix and as coating. HPMC is completely solubilized in the medium that simulates the pH of the stomach and intestine, and PVA is the polymer that allows controlling the solubility of the blend in the medium, with a differents pH. The dissolution time was monitored by UV absorbance with maximum theophylline at 269 nm. The theophylline was released immediately in the granules, and in the capsules 78.4% after 30 minutes and 97.4%, after 120 minutes. Thus, PVA can potentially control the drug solubilization, contributing to obtaining modified release systems.

  1. A nanofluidic bioarray chip for fast and high-throughput detection of antibodies in biological fluids

    Science.gov (United States)

    Lee, Jonathan; Gulzar, Naveed; Scott, Jamie K.; Li, Paul C. H.

    2012-10-01

    Immunoassays have become a standard in secretome analysis in clinical and research analysis. In this field there is a need for a high throughput method that uses low sample volumes. Microfluidics and nanofluidics have been developed for this purpose. Our lab has developed a nanofluidic bioarray (NBA) chip with the goal being a high throughput system that assays low sample volumes against multiple probes. A combination of horizontal and vertical channels are produced to create an array antigens on the surface of the NBA chip in one dimension that is probed by flowing in the other dimension antibodies from biological fluids. We have tested the NBA chip by immobilizing streptavidin and then biotinylated peptide to detect the presence of a mouse monoclonal antibody (MAb) that is specific for the peptide. Bound antibody is detected by an AlexaFluor 647 labeled goat (anti-mouse IgG) polyclonal antibody. Using the NBA chip, we have successfully detected peptide binding by small-volume (0.5 μl) samples containing 50 attomoles (100 pM) MAb.

  2. Improved solid-phase extraction method for systematic toxicological analysis in biological fluids.

    Science.gov (United States)

    Soriano, T; Jurado, C; Menéndez, M; Repetto, M

    2001-03-01

    A method for the simultaneous qualitative and quantitative determination of drugs of abuse (opiates, cocaine, or amphetamines) and prescribed drugs (tricyclic antidepressants, phenotiazines, benzodiazepines, etc.) in biological fluids--blood, urine, bile, and gastric contents--was developed. This procedure involves solid-phase extraction with Bond-Elut Certify columns followed by analysis by gas chromatography-nitrogen-phosphorus detection (GC-NPD) and confirmation by gas chromatography-mass spectrometry (GC-MS), after derivatization, when necessary. Pretreatment was performed on all samples: sonication for 15 min plus enzymatic hydrolysis with beta-glucuronidase in urine. With respect to the internal standards, nalorphine and trihexylamine were used for basic substances, allobarbital for acidic drugs, and prazepam for benzodiazepines. Acidic and basic compounds were extracted from different aliquots of samples at different pH levels: 6-6.5 for the acidic and neutral and 8-8.5 for the basic and the benzodiazepines. Several areas of experimental design were considered in the process of method optimization. These included internal standards, pH, sonication, flow rate and washing solvents. It was found that systematic analysis could be reliably performed using optimized extraction conditions. The recovery rates for the compounds tested were always higher than 61.02%.

  3. Metabolism and toxicological analysis of synthetic cannabinoids in biological fluids and tissues.

    Science.gov (United States)

    Presley, B C; Gurney, S M R; Scott, K S; Kacinko, S L; Logan, B K

    2016-07-01

    Synthetic cannabinoids, which began proliferating in the United States in 2009, have gone through numerous iterations of modification to their chemical structures. More recent generations of compounds have been associated with significant adverse outcomes following use, including cognitive and psychomotor impairment, seizures, psychosis, tissue injury and death. These effects increase the urgency for forensic and public health laboratories to develop methods for the detection and identification of novel substances, and apply these to the determination of their metabolism and disposition in biological samples. This comprehensive review describes the history of the appearance of the drugs in the United States, discusses the naming conventions emerging to designate new structures, and describes the most prominent new compounds linked to the adverse effects now associated with their use. We review in depth the metabolic pathways that have been elucidated for the major members of each of the prevalent synthetic cannabinoid drug subclasses, the enzyme systems responsible for their metabolism, and the use of in silico approaches to assist in predicting and identifying the metabolites of novel compounds and drug subclasses that will continue to appear. Finally, we review and critique analytical methods applied to the detection of the drugs and their metabolites, including immunoassay screening, and liquid chromatography mass spectrometry confirmatory techniques applied to urine, serum, whole blood, oral fluid, hair, and tissues. Copyright © 2016 Central Police University.

  4. Phytochemical Characterization and Biological Evaluation of the Aqueous and Supercritical Fluid Extracts from Salvia sclareoides Brot

    Directory of Open Access Journals (Sweden)

    Batista Daniela

    2017-04-01

    Full Text Available Plants belonging to the genus Salvia (Lamiaceae are known to have a wide range of biological properties. In this work, extracts obtained from the aerial parts of Salvia sclareoides Brot. were evaluated to investigate their chemical composition, toxicity, bioactivity, and stability under in vitro gastrointestinal conditions. The composition of the supercritical fluid extract was determined by GC and GC-MS, while the identification of the infusion constituents was performed by HPLC-DAD and LC-MS. The in vitro cytotoxicity of both extracts (0-2 mg/mL was evaluated in Caco-2 cell lines by the MTT assay. The anti-inflammatory and anticholinesterase activities were determined through the inhibition of cyclooxygenase-1 and acetylcholinesterase enzymes, while β-carotene/linoleic acid bleaching test and the DPPH assays were used to evaluate the antioxidant activity. The infusion inhibited cyclooxygenase-1 (IC50 = 271.0 μg/mL, and acetylcholinesterase (IC50 = 487.7 μg/ mL enzymes, also demonstrated significant antioxidant properties, as evaluated by the DPPH (IC50 = 10.4 μg/mL and β-carotene/linoleic acid (IC50 = 30.0 μg/mL assays. No remarkable alterations in the composition or in the bioactivities of the infusion were observed after in vitro digestion, which supports the potential of S. sclareoides as a source of bioactive ingredients with neuroprotective, anti-inflammatory and antioxidant properties.

  5. Quantitative X-ray analysis of biological fluids: the microdroplet technique

    International Nuclear Information System (INIS)

    Roinel, N.

    1988-01-01

    X-ray microanalysis can be used to quantitatively determine the elemental composition of microvolumes of biological fluids. This article describes the various steps in preparation of microdroplets for analysis: The manufacturing of micropipettes, the preparation of the specimen support, the deposition of droplets on the support, shock-freezing, and lyophilization. Examples of common artifacts (incomplete rehydration prior to freezing or partial rehydration after lyophilization) are demonstrated. Analysis can be carried out either by wavelength-dispersive analysis, which is the most sensitive method, or by energy-dispersive analysis, which is more commonly available. The minimum detectable concentration is 0.05 mmol.liter-1 for 0.1-nl samples analyzed by wavelength-dispersive spectrometry and 0.5-1 mmol.liter-1 for samples analyzed by energy-dispersive spectrometry. A major problem, especially in wavelength-dispersive analysis, where high beam currents are used, is radiation damage to the specimen; in particular chloride (but also other elements) can be lost. Quantitative analysis requires the use of standard solutions with elemental concentration in the same range as those present in the specimen

  6. Development and characterization of a radioimmunoassay to measure human tissue kallikrein in biological fluids

    Energy Technology Data Exchange (ETDEWEB)

    Bagshaw, A.F.; Whicher, J.T. (Bristol Royal Infirmary (UK)); Bhoola, K.D.; Lemon, M.J.C. (Bristol Univ. (UK). Medical School)

    1984-05-01

    A direct radioimmunoassay has been developed to measure tissue kallikrein in human biological fluids, including serum, plasma, urine, pancreatic juice and saliva. Purified kallikreins from human urine and human saliva were used to raise rabbit antibody and each labelled with Na/sup 125/I for use in the radioimmunoassay. Comparison of the different antigen-antibody systems was then made. Bound and free enzyme were separated by a double-antibody technique. The usable range of the standard curve was from 2.5 to 100 ..mu..g kallikrein/1. The intra-assay coefficient of variation was 4.7%, the interassay coefficient of variation 8.9% and the recoveries of purified kallikrein added to the samples were 99.3, 96.0, 110.8 and 81.2% for urine, saliva, serum and plasma respectively. Parallel dilution curves were obtained for serum and plasma, as well as urine, saliva and pancreatic juice. Plasma anticoagulated with EDTA or heparin gave consistently lower values than serum, when measured in the radioimmunoassay. From eight different subjects plasma (EDTA) values were on average 50% lower than those of serum, and subsequent experiments revealed that treatment of blood with some anticoagulants, in particular heparin and EDTA, resulted in a marked reduction in measurable tissue kallikrein.

  7. Influence of sterilization on the mineralization of titanium implants induced by incubation in various biological model fluids.

    Science.gov (United States)

    Serro, A P; Saramago, B

    2003-11-01

    The aim of this work was to investigate the effect of the sterilization processes on the mineralization of titanium implants induced by incubation in various biological model fluids. Titanium samples were submitted to the following sterilization processes used for implant materials: steam autoclaving, glow discharge Ar plasma treatment and gamma-irradiation. The modification of the treated surfaces was evaluated by contact angle determinations, X-ray photoelectron spectroscopy (XPS), laser profilometry and X-ray diffraction. The most significant modifications were detected on the wettability: while the samples treated with Ar plasma became highly hydrophilic (water contact angle approximately 0 degrees), gamma-irradiation and steam sterilization induced an increase in the hydrophobicity. After being sterilized, the samples were incubated for one week in three biological model fluids: Hanks' Balanced Salt Solution, Kokubo's simulated body fluid (SBF) and a fluid, designated by SBF0, with the same composition of SBF but without buffer TRIS. The level of mineralization of the incubated Ti samples, assessed by dynamic contact angle analysis, scanning electron microscopy, electron dispersive spectroscopy and XPS, indicated that the early stages of mineralization are essentially independent of the sterilization method. In contrast, the incubating fluid plays a determinant role, SBFO being the most efficient medium for biomineralization of titanium.

  8. Direct detection of illicit drugs from biological fluids by desorption/ionization mass spectrometry with nanoporous silicon microparticles.

    Science.gov (United States)

    Guinan, T M; Kirkbride, P; Della Vedova, C B; Kershaw, S G; Kobus, H; Voelcker, N H

    2015-12-07

    Surface-assisted laser desorption/ionization mass spectrometry (SALDI-MS) is a high throughput analytical technique capable of detecting low molecular weight analytes, including illicit drugs, and with potential applications in forensic toxicology as well as athlete and workplace testing, particularly for biological fluids (oral fluids, urine and blood). However, successful detection of illicit drugs using SALDI-MS often requires extraction steps to reduce the inherent complexity of biological fluids. Here, we demonstrate an all-in-one extraction and analytical system consisting of hydrophobically functionalized porous silicon microparticles (pSi-MPs) for affinity SALDI-MS of prescription and illicit drugs. This novel approach allows for the analysis of drugs from multiple biological fluids without sample preparation protocols. The effect of pSi-MP size, pore diameter, pore depth and functionalization on analytical performance is investigated. pSi-MPs were optimized for the rapid and high sensitivity detection of methadone, cocaine and 3,4-methylenedioxymethamphetamine (MDMA). This optimized system allowed extraction and detection of methadone from spiked saliva and clinical urine samples. Furthermore, by detecting oxycodone in additional clinical saliva and plasma samples, we were able to demonstrate the versatility of the pSi-MP SALDI-MS technique.

  9. Liquid separation techniques coupled with mass spectrometry for chiral analysis of pharmaceuticals compounds and their metabolites in biological fluids.

    Science.gov (United States)

    Erny, G L; Cifuentes, A

    2006-02-24

    Determination of the chiral composition of drugs is nowadays a key step in order to determine purity, activity, bioavailability, biodegradation, etc., of pharmaceuticals. In this article, works published for the last 5 years on the analysis of chiral drugs by liquid separation techniques coupled with mass spectrometry are reviewed. Namely, chiral analysis of pharmaceuticals including, e.g., antiinflammatories, antihypertensives, relaxants, etc., by liquid chromatography-mass spectrometry and capillary electrophoresis-mass spectrometry are included. The importance and interest of the analysis of the enantiomers of the active compound and its metabolites in different biological fluids (plasma, urine, cerebrospinal fluid, etc.) are also discussed.

  10. An improved mass spectrometry-based measurement of NO metabolites in biological fluids.

    Science.gov (United States)

    Yang, Xingbin; Bondonno, Catherine P; Indrawan, Adeline; Hodgson, Jonathan M; Croft, Kevin D

    2013-03-01

    Assessment of NO metabolism in vivo relies on the accurate measurement of its metabolites nitrite (NO(2)(-)), nitrate (NO(3)(-)), and nitrosothiols (RSNOs) in biological fluids. We report a sensitive method to simultaneously determine NO(2)(-) and NO(3)(-) in biological matrixes. Tetraoctylammonium was used to catalyze the complete conversion of NO(2)(-) and NO(3)(-) to stable pentafluorobenzyl (PFB) derivatives directly from aqueous acetone medium before gas chromatography and negative-ion chemical ionization mass spectrometry (GC/NICI/MS). This catalyst dramatically improved the yield of PFB derivatives for NO(2)(-) (4.5 times) and NO(3)(-) (55 times) compared to noncatalyzed derivatization methods. Analysis was performed using (15)N-labeled internal standards by selected-ion monitoring at m/z 46 for fragment NO(2)(-) and m/z 47 for its isotope analogue, (15)NO(2)(-), and m/z 62 for NO(3)(-) and m/z 63 for (15)NO(3)(-). This method allowed specific detection of both PFB derivatives over a wide dynamic range with a limit of detection below 4.5 pg for NO(2)(-) and 2.5 pg for NO(3)(-). After the specific conversion of RSNOs by HgCl(2) to NO(2)(-), this GC/NICI/MS analysis was used to measure RSNOs in plasma. A further comparison with the widely used tri-iodide chemiluminescence (I(3)(-)-CL) assay indicated that the GC/MS assay validated the lower physiological RSNO and nitrite levels reported using I(3)(-)-CL detection compared with values obtained using UV-photolysis methods. Plasma levels of RSNOs determined by GC/MS and I(3)(-)-CL were well correlated (r = 0.8). The improved GC/MS method was successfully used to determine the changes in plasma, urinary, and salivary NO(2)(-) and NO(3)(-) as well as plasma RSNOs in humans after either a low-NO(3)(-) or a high-NO(3)(-) meal. Copyright © 2012 Elsevier Inc. All rights reserved.

  11. Biology of lysenin, a protein in the coelomic fluid of the earthworm Eisenia foetida.

    Science.gov (United States)

    Kobayashi, Hideshi; Ohta, Naoshi; Umeda, Masato

    2004-01-01

    Lysenin is a protein of 33?kDa in the coelomic fluid (CF) of the earthworm Eisenia foetida. It differs from other biologically active proteins, such as fetidins, eiseniapore, and coelomic cytolytic factor (CCF-1), that have been found in Eisenia foetida, in terms of both its biochemical and its biological characteristics. The large coelomocytes and free chloragocytes in the typhlosole of Eisenia foetida appear to be the cells that produce lysenin since the mRNA for lysenin and immunoreactive lysenin have been found in these cells. Lysenin binds specifically to sphingomyelin (SM) but not to other phospholipids in cell membranes. After binding to the cell membranes of target cells, lysenin forms oligomers in an SM-dependent manner, with subsequent formation of pores with a hydrodynamic diameter of approximately 3?nm. The biochemical interactions between lysenin and SM in cell membranes are responsible for the pharmacological activities of lysenin and of CF that contains lysenin in vertebrates, such as hemolysis, cytotoxicity, and contraction of smooth muscle in vitro and vasodepressor activity and lethality in vivo. When incubated with SM-liposomes, CF and lysenin lost some or all of their activity, an observation that suggests that SM might be involved in the induction of the various activities of lysenin and CF. However, in general, lysenin is neither cytotoxic nor lethal to invertebrates. An attempt has been made to explain the differences in the responses to lysenin and CF between vertebrates and invertebrates in terms of the presence or absence of SM in the various animals. Among Protostomia, SM is absent in Lophotrochozoa, with the exception of some molluscan species, but it is present in Ecdysozoa, with the exception of Nematomorpha and flies. Among Deuterostomia, Echinodermata and Hemichordata lack SM but SM is found in Chordata. Thus, the difference in terms of the response to lysenin between invertebrates and vertebrates cannot be fully explained by

  12. Perspective: Differential dynamic microscopy extracts multi-scale activity in complex fluids and biological systems

    Science.gov (United States)

    Cerbino, Roberto; Cicuta, Pietro

    2017-09-01

    Differential dynamic microscopy (DDM) is a technique that exploits optical microscopy to obtain local, multi-scale quantitative information about dynamic samples, in most cases without user intervention. It is proving extremely useful in understanding dynamics in liquid suspensions, soft materials, cells, and tissues. In DDM, image sequences are analyzed via a combination of image differences and spatial Fourier transforms to obtain information equivalent to that obtained by means of light scattering techniques. Compared to light scattering, DDM offers obvious advantages, principally (a) simplicity of the setup; (b) possibility of removing static contributions along the optical path; (c) power of simultaneous different microscopy contrast mechanisms; and (d) flexibility of choosing an analysis region, analogous to a scattering volume. For many questions, DDM has also advantages compared to segmentation/tracking approaches and to correlation techniques like particle image velocimetry. The very straightforward DDM approach, originally demonstrated with bright field microscopy of aqueous colloids, has lately been used to probe a variety of other complex fluids and biological systems with many different imaging methods, including dark-field, differential interference contrast, wide-field, light-sheet, and confocal microscopy. The number of adopting groups is rapidly increasing and so are the applications. Here, we briefly recall the working principles of DDM, we highlight its advantages and limitations, we outline recent experimental breakthroughs, and we provide a perspective on future challenges and directions. DDM can become a standard primary tool in every laboratory equipped with a microscope, at the very least as a first bias-free automated evaluation of the dynamics in a system.

  13. Empirical resistive-force theory for slender biological filaments in shear-thinning fluids.

    Science.gov (United States)

    Riley, Emily E; Lauga, Eric

    2017-06-01

    Many cells exploit the bending or rotation of flagellar filaments in order to self-propel in viscous fluids. While appropriate theoretical modeling is available to capture flagella locomotion in simple, Newtonian fluids, formidable computations are required to address theoretically their locomotion in complex, nonlinear fluids, e.g., mucus. Based on experimental measurements for the motion of rigid rods in non-Newtonian fluids and on the classical Carreau fluid model, we propose empirical extensions of the classical Newtonian resistive-force theory to model the waving of slender filaments in non-Newtonian fluids. By assuming the flow near the flagellum to be locally Newtonian, we propose a self-consistent way to estimate the typical shear rate in the fluid, which we then use to construct correction factors to the Newtonian local drag coefficients. The resulting non-Newtonian resistive-force theory, while empirical, is consistent with the Newtonian limit, and with the experiments. We then use our models to address waving locomotion in non-Newtonian fluids and show that the resulting swimming speeds are systematically lowered, a result which we are able to capture asymptotically and to interpret physically. An application of the models to recent experimental results on the locomotion of Caenorhabditis elegans in polymeric solutions shows reasonable agreement and thus captures the main physics of swimming in shear-thinning fluids.

  14. Empirical resistive-force theory for slender biological filaments in shear-thinning fluids

    Science.gov (United States)

    Riley, Emily E.; Lauga, Eric

    2017-06-01

    Many cells exploit the bending or rotation of flagellar filaments in order to self-propel in viscous fluids. While appropriate theoretical modeling is available to capture flagella locomotion in simple, Newtonian fluids, formidable computations are required to address theoretically their locomotion in complex, nonlinear fluids, e.g., mucus. Based on experimental measurements for the motion of rigid rods in non-Newtonian fluids and on the classical Carreau fluid model, we propose empirical extensions of the classical Newtonian resistive-force theory to model the waving of slender filaments in non-Newtonian fluids. By assuming the flow near the flagellum to be locally Newtonian, we propose a self-consistent way to estimate the typical shear rate in the fluid, which we then use to construct correction factors to the Newtonian local drag coefficients. The resulting non-Newtonian resistive-force theory, while empirical, is consistent with the Newtonian limit, and with the experiments. We then use our models to address waving locomotion in non-Newtonian fluids and show that the resulting swimming speeds are systematically lowered, a result which we are able to capture asymptotically and to interpret physically. An application of the models to recent experimental results on the locomotion of Caenorhabditis elegans in polymeric solutions shows reasonable agreement and thus captures the main physics of swimming in shear-thinning fluids.

  15. Application of LC–MS/MS for quantitative analysis of glucocorticoids and stimulants in biological fluids

    Directory of Open Access Journals (Sweden)

    Jamshed Haneef

    2013-10-01

    Full Text Available Liquid chromatography tandem mass chromatography (LC–MS/MS is an important hyphenated technique for quantitative analysis of drugs in biological fluids. Because of high sensitivity and selectivity, LC–MS/MS has been used for pharmacokinetic studies, metabolites identification in the plasma and urine. This manuscript gives comprehensive analytical review, focusing on chromatographic separation approaches (column packing materials, column length and mobile phase as well as different acquisition modes (SIM, MRM for quantitative analysis of glucocorticoids and stimulants. This review is not meant to be exhaustive but rather to provide a general overview for detection and confirmation of target drugs using LC–MS/MS and thus useful in the doping analysis, toxicological studies as well as in pharmaceutical analysis. Keywords: LC–MS/MS, Ionization techniques, Glucocorticoids, Stimulants, Hyphenated techniques, Biological fluid

  16. Mini Review - Analysis of Artemether and Dihydroartemisinin by high performance high liquid chromatography in biological fluids-issues and solutions.

    Science.gov (United States)

    Ali, Shabana; Jafery, Nusrat; Farhat, Kulsoom; Waheed, Akbar

    2017-07-01

    Artemether-Lumefantrine is the most widely recommended antimalarial combination used to treat millions of patients suffering from malaria. Artemether undergoes rapid metabolism and gets converted to its active metabolite dihydroartemisisn. Drug analysis is a vital aspect to evaluate drugs in research. There are a number of methods available for the determination of artemether in biological fluids. These methods include HPLC based UV detection, GS-MS, HPLC-ECD and HPLC-MS/MS. This article reviews different methods for the determination of artemether in the biological fluids. Among the available methods HPLC-MS/MS proves to be the most accurate and reliable one for analysis. This has the advantage of improved sensitivity and selectivity with smaller sample volume.

  17. The radioimmunoassay of biologically active compounds in parotid fluid and plasma

    International Nuclear Information System (INIS)

    Walker, R.F.; Read, G.F.; Riad-Fahmy, D.

    1977-01-01

    The potential value of parotid fluid estimations of clomipramine, d-norgestrel, and cortisol have been evaluated for assessment of clinical status and patient compliance. Excellent agreement (r > 0.9) was observed when parotid fluid samples were assayed with and without chromatographic purification. Clomipramine levels following oral dosage (150mg) rose steadily to a maximum in plasma but showed wide fluctuations in parotid fluid. Following an oral dose of d-norgestrel(0.3mg), parotid fluid levels rose steadily to a maximum but plasma response was biphasic making correlation impossible. The sensitivity and high throughput of the d-norgestrel methodology suggests its use in evaluating patient compliance in large scale fertility control programmes. Changes in circulating cortisol concentrations were rapidly and accurately reflected in parotid fluid in normal volunteers. Parotid fluid cortisol showed a market diurnal rythm, suppression to low levels after dexamethasone, and elevation following Synacthen. Low levels after Synacthen stimulation in a patient with secondary adrenal atrophy and constant high levels in Cushingoid patients indicate that parotid fluid cortisol levels could be used for accurate adrenocortical evaluation. The value in rapid screening procedures is stressed since the assay can be performed directly on only 10μl of parotid fluid. (orig./AJ) [de

  18. A soluble, high-affinity, interleukin-4-binding protein is present in the biological fluids of mice

    International Nuclear Information System (INIS)

    Fernandez-Botran, R.; Vitetta, E.S.

    1990-01-01

    Cytokines such as interleukin 4 (IL-4) play a key role in the regulation of immune responses, but little is known about how their multiple activities are regulated in vivo. In this report, we demonstrate that an IL-4-binding protein (IL-4BP) is constitutively present in the biological fluids of mice (serum, ascites fluid, and urine). Binding of 125 I-labeled IL-4 to the IL-4BP is specific and saturable and can be inhibited by an excess of unlabeled IL-4 but not IL-2. The IL-4BP binds IL-4 with an affinity similar to that reported for the cellular IL-4 with an affinity similar to that reported for the cellular IL-4 receptor (K d ∼7 x 10 -11 M) and has a molecular mass of 30-40 kDa and pI values of 3.6-4.8. IL-4BP-containing biological fluids or purified IL-4BP competitively inhibit the binding of 125 I-labeled IL-4 to mouse T or B cells and inhibit the biological activity of IL-4 but not IL-2. The serum levels of IL-4BP in severe combined immunodeficiency (SCID) mice are lower than those of normal mice. The above findings suggest that IL-4BP plays an important immunoregulatory role in vivo

  19. High-performance liquid chromatographic assay for genistein in biological fluids.

    Science.gov (United States)

    Supko, J G; Phillips, L R

    1995-04-07

    A specific, sensitive and technically convenient HPLC method for assaying genistein in biological fluids has been developed. The compound and 4-hydroxybenzophenone, added as an internal standard, were efficiently isolated from both plasma and urine by extraction with tert-butyl methyl ether. Following evaporation of the organic solvent, the extract was reconstituted with methanol-0.05 M ammonium acetate buffer, pH 4.7 (30:70, v/v), and loaded onto a 4 microns Nova-Pak C8 column (15 cm x 3.9 mm I.D.). Chromatography was performed at ambient temperature using a mobile phase of acetonitrile-0.05 M ammonium formate buffer, pH 4.0 (27:73, v/v), at a flow-rate of 1.0 ml/min, with UV detection at 260 nm. Mean values of the tR for the drug and internal standard, determined from chromatograms of the 1 microgram/ml plasma standard during a 6 month period, were 8.27 +/- 0.55 and 11.92 +/- 0.71 min, respectively (S.D., n = 29). With a sample volume of 50 microliters, the lowest concentration of genistein included in the plasma standard curve, 0.020 microgram/ml, was quantified with a 10.7% R.S.D. over a 5 month period. Plasma standards having concentrations of 0.050 to 1.02 micrograms/ml exhibited R.S.D. values ranging from 2.3 to 6.1%. The drug was quantified in urine with similar reproducibility. The sensitivity of the assay was adequate for characterizing the plasma pharmacokinetics of genistein in the mouse and dog. However, a 10-fold improvement in sensitivity was afforded by increasing the sample size to 250 microliters, without otherwise modifying the method. Thus, this procedure may prove suitable for determining plasma and urine levels of genistein in humans consuming dietary isoflavonoids in a much more convenient manner than permitted by existing methodology.

  20. A review of chromatographic methods for the determination of water- and fat-soluble vitamins in biological fluids.

    Science.gov (United States)

    Karaźniewicz-Łada, Marta; Główka, Anna

    2016-01-01

    Vitamins are an essential element of nutrition and thus contribute to human health. Vitamins catalyze many biochemical reactions and their lack or excess can cause health problems. Therefore, monitoring vitamin concentrations in plasma or other biological fluids may be useful in the diagnosis of various disorders as well as in the treatment process. Several chromatographic methods have been developed for the determination of these compounds in biological samples, including high-performance liquid chromatography with UV and fluorescence detection. Recently, high-performance liquid chromatography with tandem mass spectrometry methods have been widely used for the determination of vitamins in complex matrices because of their high sensitivity and selectivity. This method requires preconditioning of samples for analysis, including protein precipitation and/or various extraction techniques. The choice of method may depend on the desired cost, convenience, turnaround time, specificity, and accuracy of the information to be obtained. This article reviews the recently reported chromatographic methods used for determination of vitamins in biological fluids. Relevant papers published mostly during the last 5 years were identified by an extensive PubMed search using appropriate keywords. Particular attention was given to the preparation steps and extraction techniques. This report may be helpful in the selection of procedures that are appropriate for certain types of biological materials and analytes. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  1. Modern methods for vancomycin determination in biological fluids by methods based on high-performance liquid chromatography--A review.

    Science.gov (United States)

    Javorska, Lenka; Krcmova, Lenka Kujovska; Solichova, Dagmar; Solich, Petr; Kaska, Milan

    2016-01-01

    Vancomycin is a glycopeptide antibiotic used in the therapy of severe bacterial infection. The monitoring of vancomycin levels is recommended because of its narrow therapeutic index and toxicity. This measurement is especially appropriate in patients with unstable renal functions, who receive high doses of vancomycin or present serious bacterial infections accompanied by important sequestration of liquids when it could be difficult to achieve the optimal therapeutic dose. Most of the methods for vancomycin determination in routine practice are immunoassays. However, chromatography-based techniques in combination with UV or mass spectrometry detection provide results with greater accuracy and precision also in complicated biological matrices. This review provides a detailed overview of modern approaches for the chromatographic separation of vancomycin in various biological samples and useful sample preparation procedures for vancomycin determination in various biological fluids. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  2. A peptide-based biological coating for enhanced corrosion resistance of titanium alloy biomaterials in chloride-containing fluids.

    Science.gov (United States)

    Muruve, Noah; Feng, Yuanchao; Platnich, Jaye; Hassett, Daniel; Irvin, Randall; Muruve, Daniel; Cheng, Frank

    2017-03-01

    Titanium alloys are common materials in the manufacturing of dental and orthopedic implants. Although these materials exhibit excellent biocompatibility, corrosion in response to biological fluids can impact prosthesis performance and longevity. In this work, a PEGylated metal binding peptide (D-K122-4-PEG), derived from bacteria Pseudomonas aeruginosa, was applied on a titanium (Ti) alloy, and the corrosion resistance of the coated alloy specimen was investigated in simulated chloride-containing physiological fluids by electrochemical impedance spectroscopy and micro-electrochemical measurements, surface characterization, and biocompatibility testing. Compared to uncoated specimen, the D-K122-4-PEG-coated Ti alloy demonstrates decreased corrosion current density without affecting the natural passivity. Morphological analysis using atomic force microscopy and scanning electron microscopy confirms a reduction in surface roughness of the coated specimens in the fluids. The D-K122-4-PEG does not affect the binding of HEK-293T cells to the surface of unpolished Ti alloy, nor does it increase the leukocyte activation properties of the metal. D-K122-4-PEG represents a promising coating to enhance the corrosion resistance of Ti alloys in physiological fluids, while maintaining an excellent biocompatibility.

  3. Analysis of Investigational Drugs in Biological Fluids - Method Development and Analysis of Pre-Clinical Samples

    National Research Council Canada - National Science Library

    Lin, Emil

    2001-01-01

    ... (and metabolites and artesunate). Work on routine analyses of biological specimens during this period was performed for studies that required determination of concentrations of artelinic acid, choroquine...

  4. An overview of the analytical methods for the determination of organic ultraviolet filters in biological fluids and tissues

    Energy Technology Data Exchange (ETDEWEB)

    Chisvert, Alberto, E-mail: alberto.chisvert@uv.es [Departamento de Quimica Analitica, Facultad de Quimica, Universitat de Valencia, Doctor Moliner St. 50, 46100 Burjassot, Valencia (Spain); Leon-Gonzalez, Zacarias [Unidad Analitica, Instituto de Investigacion Sanitaria Fundacion Hospital La Fe, 46009 Valencia (Spain); Tarazona, Isuha; Salvador, Amparo [Departamento de Quimica Analitica, Facultad de Quimica, Universitat de Valencia, Doctor Moliner St. 50, 46100 Burjassot, Valencia (Spain); Giokas, Dimosthenis [Laboratory of Analytical Chemistry, Department of Chemistry, University of Ioannina, 45110 Ioannina (Greece)

    2012-11-08

    Highlights: Black-Right-Pointing-Pointer Papers describing the determination of UV filters in fluids and tissues are reviewed. Black-Right-Pointing-Pointer Matrix complexity and low amounts of analytes require effective sample treatments. Black-Right-Pointing-Pointer The published papers do not cover the study of all the substances allowed as UV filters. Black-Right-Pointing-Pointer New analytical methods for UV filters determination in these matrices are encouraged. - Abstract: Organic UV filters are chemical compounds added to cosmetic sunscreen products in order to protect users from UV solar radiation. The need of broad-spectrum protection to avoid the deleterious effects of solar radiation has triggered a trend in the cosmetic market of including these compounds not only in those exclusively designed for sun protection but also in all types of cosmetic products. Different studies have shown that organic UV filters can be absorbed through the skin after topical application, further metabolized in the body and eventually excreted or bioaccumulated. These percutaneous absorption processes may result in various adverse health effects, such as genotoxicity caused by the generation of free radicals, which can even lead to mutagenic or carcinogenic effects, and estrogenicity, which is associated with the endocrine disruption activity caused by some of these compounds. Due to the absence of official monitoring protocols, there is a demand for analytical methods that enable the determination of UV filters in biological fluids and tissues in order to retrieve more information regarding their behavior in the human body and thus encourage the development of safer cosmetic formulations. In view of this demand, there has recently been a noticeable increase in the development of sensitive and selective analytical methods for the determination of UV filters and their metabolites in biological fluids (i.e., urine, plasma, breast milk and semen) and tissues. The complexity of

  5. An overview of the analytical methods for the determination of organic ultraviolet filters in biological fluids and tissues

    International Nuclear Information System (INIS)

    Chisvert, Alberto; León-González, Zacarías; Tarazona, Isuha; Salvador, Amparo; Giokas, Dimosthenis

    2012-01-01

    Highlights: ► Papers describing the determination of UV filters in fluids and tissues are reviewed. ► Matrix complexity and low amounts of analytes require effective sample treatments. ► The published papers do not cover the study of all the substances allowed as UV filters. ► New analytical methods for UV filters determination in these matrices are encouraged. - Abstract: Organic UV filters are chemical compounds added to cosmetic sunscreen products in order to protect users from UV solar radiation. The need of broad-spectrum protection to avoid the deleterious effects of solar radiation has triggered a trend in the cosmetic market of including these compounds not only in those exclusively designed for sun protection but also in all types of cosmetic products. Different studies have shown that organic UV filters can be absorbed through the skin after topical application, further metabolized in the body and eventually excreted or bioaccumulated. These percutaneous absorption processes may result in various adverse health effects, such as genotoxicity caused by the generation of free radicals, which can even lead to mutagenic or carcinogenic effects, and estrogenicity, which is associated with the endocrine disruption activity caused by some of these compounds. Due to the absence of official monitoring protocols, there is a demand for analytical methods that enable the determination of UV filters in biological fluids and tissues in order to retrieve more information regarding their behavior in the human body and thus encourage the development of safer cosmetic formulations. In view of this demand, there has recently been a noticeable increase in the development of sensitive and selective analytical methods for the determination of UV filters and their metabolites in biological fluids (i.e., urine, plasma, breast milk and semen) and tissues. The complexity of the biological matrix and the low concentration levels of these compounds inevitably impose sample

  6. Molecular biology of the blood-brain and the blood-cerebrospinal fluid barriers: similarities and differences

    Directory of Open Access Journals (Sweden)

    Redzic Zoran

    2011-01-01

    Full Text Available Abstract Efficient processing of information by the central nervous system (CNS represents an important evolutionary advantage. Thus, homeostatic mechanisms have developed that provide appropriate circumstances for neuronal signaling, including a highly controlled and stable microenvironment. To provide such a milieu for neurons, extracellular fluids of the CNS are separated from the changeable environment of blood at three major interfaces: at the brain capillaries by the blood-brain barrier (BBB, which is localized at the level of the endothelial cells and separates brain interstitial fluid (ISF from blood; at the epithelial layer of four choroid plexuses, the blood-cerebrospinal fluid (CSF barrier (BCSFB, which separates CSF from the CP ISF, and at the arachnoid barrier. The two barriers that represent the largest interface between blood and brain extracellular fluids, the BBB and the BCSFB, prevent the free paracellular diffusion of polar molecules by complex morphological features, including tight junctions (TJs that interconnect the endothelial and epithelial cells, respectively. The first part of this review focuses on the molecular biology of TJs and adherens junctions in the brain capillary endothelial cells and in the CP epithelial cells. However, normal function of the CNS depends on a constant supply of essential molecules, like glucose and amino acids from the blood, exchange of electrolytes between brain extracellular fluids and blood, as well as on efficient removal of metabolic waste products and excess neurotransmitters from the brain ISF. Therefore, a number of specific transport proteins are expressed in brain capillary endothelial cells and CP epithelial cells that provide transport of nutrients and ions into the CNS and removal of waste products and ions from the CSF. The second part of this review concentrates on the molecular biology of various solute carrier (SLC transport proteins at those two barriers and underlines

  7. Derivatization reactions in the gas—liquid chromatographic analysis of drugs in biological fluids

    NARCIS (Netherlands)

    Hulshoff, A.; Lingeman, H.

    1984-01-01

    Alkylation, acylation, silylation and other derivatization reactions applied to the gas chromatographic analysis of drugs in biological matrices are reviewed. Reaction conditions are discussed in relation to reaction mechanisms. Detector-oriented labelling of drugs, and derivatization with chiral

  8. Banking of biological fluids for studies of disease-associated protein biomarkers.

    NARCIS (Netherlands)

    Schrohl, A.S.; Wurtz, S.; Kohn, E.; Banks, R.E.; Nielsen, H.J.; Sweep, F.C.; Brunner, N.

    2008-01-01

    With the increasing demand of providing personalized medicine the need for biobanking of biological material from individual patients has increased. Such samples are essential for molecular research aimed at characterizing diseases at several levels ranging from epidemiology and diagnostic and

  9. Purification of drugs from biological fluids by counter-current chromatography.

    Science.gov (United States)

    Hochlowski, Jill E; Pan, Jeffrey Y; Searle, Philip A; Buck, Wayne R; Spanton, Stephen G

    2009-08-21

    Experiments were performed to demonstrate the potential of counter-current chromatography (CCC) for the isolation of drugs and their metabolites from biological matrices relevant to the metabolism studies of pharmaceutical research. Examples of typical drugs are spiked into biological media ex vivo to provide test samples for analysis. A mass spectrometer hyphenated to a CCC allows for the detection of small molecule drugs within the matrix through selected ion monitoring, and fraction collection can provide material for further structural elucidation by NMR.

  10. Preformulation and stability in biological fluids of the retrocyclin RC-101, a potential anti-HIV topical microbicide

    Directory of Open Access Journals (Sweden)

    Conrads Thomas P

    2011-07-01

    Full Text Available Abstract Background RC-101, a cationic peptide retrocyclin analog, has in vitro activity against HIV-1. Peptide drugs are commonly prone to conformational changes, oxidation and hydrolysis when exposed to excipients in a formulation or biological fluids in the body, this can affect product efficacy. We aimed to investigate RC-101 stability under several conditions including the presence of human vaginal fluids (HVF, enabling the efficient design of a safe and effective microbicide product. Stability studies (temperature, pH, and oxidation were performed by HPLC, Circular Dichroism, and Mass Spectrometry (LC-MS/MS. Additionally, the effect of HVF on formulated RC-101 was evaluated with fluids collected from healthy volunteers, or from subjects with bacterial vaginosis (BV. RC-101 was monitored by LC-MS/MS for up to 72 h. Results RC-101 was stable at pH 3, 4, and 7, at 25 and 37°C. High concentrations of hydrogen peroxide resulted in less than 10% RC-101 reduction over 24 h. RC-101 was detected 48 h after incubation with normal HVF; however, not following incubation with HVF from BV subjects. Conclusions Our results emphasize the importance of preformulation evaluations and highlight the impact of HVF on microbicide product stability and efficacy. RC-101 was stable in normal HVF for at least 48 h, indicating that it is a promising candidate for microbicide product development. However, RC-101 stability appears compromised in individuals with BV, requiring more advanced formulation strategies for stabilization in this environment.

  11. Preformulation and stability in biological fluids of the retrocyclin RC-101, a potential anti-HIV topical microbicide.

    Science.gov (United States)

    Sassi, Alexandra B; Bunge, Katherine E; Hood, Brian L; Conrads, Thomas P; Cole, Alexander M; Gupta, Phalguni; Rohan, Lisa C

    2011-07-29

    RC-101, a cationic peptide retrocyclin analog, has in vitro activity against HIV-1. Peptide drugs are commonly prone to conformational changes, oxidation and hydrolysis when exposed to excipients in a formulation or biological fluids in the body, this can affect product efficacy. We aimed to investigate RC-101 stability under several conditions including the presence of human vaginal fluids (HVF), enabling the efficient design of a safe and effective microbicide product. Stability studies (temperature, pH, and oxidation) were performed by HPLC, Circular Dichroism, and Mass Spectrometry (LC-MS/MS). Additionally, the effect of HVF on formulated RC-101 was evaluated with fluids collected from healthy volunteers, or from subjects with bacterial vaginosis (BV). RC-101 was monitored by LC-MS/MS for up to 72 h. RC-101 was stable at pH 3, 4, and 7, at 25 and 37°C. High concentrations of hydrogen peroxide resulted in less than 10% RC-101 reduction over 24 h. RC-101 was detected 48 h after incubation with normal HVF; however, not following incubation with HVF from BV subjects. Our results emphasize the importance of preformulation evaluations and highlight the impact of HVF on microbicide product stability and efficacy. RC-101 was stable in normal HVF for at least 48 h, indicating that it is a promising candidate for microbicide product development. However, RC-101 stability appears compromised in individuals with BV, requiring more advanced formulation strategies for stabilization in this environment.

  12. Serum biobank certification and the establishment of quality controls for biological fluids: examples of serum biomarker stability after temperature variation.

    Science.gov (United States)

    Chaigneau, Christine; Cabioch, Thomas; Beaumont, Katy; Betsou, Fotini

    2007-01-01

    One of the main issues in biobanking is the establishment of standard operating procedures for specimen collection, preparation and storage to control for pre-analytical variation. For biological fluids such as serum, there is currently a lack of sensitive biomarkers for the quality control of cryopreservation conditions. The process approach was used to establish an ISO 9001:2000 quality management system. Immunoenzymatic and functional assays were used to assess the stability of the following candidate quality control biomarkers: secretory phospholipase A2, matrix metalloprotease 7, transforming growth factor beta1 and anti-HBs immunoglobulin. Five product processes and their corresponding indicators were identified. In the preparation-aliquoting-storage process, no quality control indicator for serum was identified. Only matrix metalloprotease 7 showed moderate susceptibility to freeze-thaw cycles. Biomarkers that have an on-off response to temperature variation could serve as quality indicators for the core processes of biobanking, which are the preparation and storage of biological fluids. The identification of such biomarkers is needed.

  13. Parafac and PLS Applied to Determination of Captopril in Pharmaceutical Preparation and Biological Fluids by Ultraviolet Spectrophotometry

    International Nuclear Information System (INIS)

    Niazi, A.; Ghasemi, N.

    2007-01-01

    A new ultraviolet spectrophotometric method has been developed for the direct qualitative determination of captopril in pharmaceutical preparation and biological fluids such as human plasma and urine samples. The method was accomplished based on parallel factor analysis (PARAFAC) and partial least squares (PLS). The study was carried out in the pH range from 2.0 to 12.8 and with a concentration from 0.70 to 61.50 μg ml -1 of captopril. Multivariate calibration models PLS at various pH and PARAFAC were elaborated from ultraviolet spectra deconvolution and captopril determination. The best models for this system were obtained with PARAFAC and PLS at pH = 2.04 (PLS-PH2). The applications of the method for the determination of real samples were evaluated by analysis of captopril in pharmaceutical preparations and biological (human plasma and urine) fluids with satisfactory results. The accuracy of the method, evaluated through the root mean square error of prediction (RMSEP), was 0.58 for captopril with PARAFAC and 0.67 for captopril with PLS-PH2 model. Acidity constant of captopril at 25 0 C and ionic strength of 0.1 M have also been determined spectrophotometrically. The obtained pK a values of captopril are 3.90 ± 0.05 and 10.03 ± 0.08 for pK a1 and pK a2 , respectively

  14. A lab-on-a-chip device for analysis of amlodipine in biological fluids using peroxyoxalate chemiluminescence system.

    Science.gov (United States)

    Al Lawati, Haider A J; Al-Nadabi, Mira M; Varma, Gouri B; Suliman, Fakhr Eldin O; Al-Abri, Hasnaa

    2014-12-01

    A highly sensitive, rapid and economical method for the determination of amlodipine (AM) in biological fluids was developed using a peroxyoxalate chemiluminescence (CL) system in a lab-on-a-chip device. Peroxyoxalate-CL is an indirect type of CL that allows the detection of native fluorophores or compounds derivatized with fluorescent labels. Here, fluorescamine was reacted with AM, and the derivatization product was used in a bis-(2,4,6-trichlorophenyl)oxalate-CL system. Fluorescamine reacts selectively with aliphatic primary amine at neutral or basic pH. As most of the calcium channel blocker and many cardiovascular drugs do not contain primary amine, the developed method is highly selective. The parameters that influenced the CL signal intensity were studied carefully. These included the chip geometry, pH, concentration of reagents used and flow rates. Moreover, we confirmed our previous observation about the effects of imidazole, which is commonly used in the bis-(2,4,6-trichlorophenyl)oxalate-CL system as a catalyst, and found that the signal was significantly improved when imidazole was absent. Under optimized conditions, a calibration curve was obtained with a linear range (10-100 µg/L). The limit of detection was 3 µg/L, while the limit of quantification was 10 µg/L. Finally the method was applied for the determination of AM in biological fluids successfully. Copyright © 2014 John Wiley & Sons, Ltd.

  15. The adaptation of a 360° camera utilising an alternate light source (ALS) for the detection of biological fluids at crime scenes.

    Science.gov (United States)

    Sheppard, Kayleigh; Cassella, John P; Fieldhouse, Sarah; King, Roberto

    2017-07-01

    One of the most important and commonly encountered evidence types that can be recovered at crime scenes are biological fluids. Due to the ephemeral nature of biological fluids and the valuable DNA that they can contain, it is fundamental that these are documented extensively and recovered rapidly. Locating and identifying biological fluids can prove a challenging task but can aid in reconstructing a sequence of events. Alternate light sources (ALS) offer powerful non-invasive methods for locating and enhancing biological fluids utilising different wavelengths of light. Current methods for locating biological fluids using ALS's may be time consuming, as they often require close range searching of potentially large crime scenes. Subsequent documentation using digital cameras and alternate light sources can increase the investigation time and due to the cameras low dynamic range, photographs can appear under or over exposed. This study presents a technique, which allows the simultaneous detection and visualisation of semen and saliva utilising a SceneCam 360° camera (Spheron VR AG), which was adapted to integrate a blue Crime Lite XL (Foster+Freeman). This technique was investigated using different volumes of semen and saliva, on porous and non-porous substrates, and the ability to detect these at incremental distances from the substrate. Substrate type and colour had a significant effect on the detection of the biological fluid, with limited fluid detection on darker substrates. The unique real-time High Dynamic range (HDR) ability of the SceneCam significantly enhanced the detection of biological fluids where background fluorescence masked target fluorescence. These preliminary results are presented as a proof of concept for combining 360° photography using HDR and an ALS for the detection of biological stains, within a scene, in real time, whilst conveying spatial relationships of staining to other evidence. This technique presents the opportunity to

  16. Surfaces resistant to fouling from biological fluids: towards bioactive surfaces for real applications

    Czech Academy of Sciences Publication Activity Database

    Rodriguez-Emmenegger, Cesar; Houska, Milan; Bologna Alles, A.; Brynda, Eduard

    2012-01-01

    Roč. 12, č. 10 (2012), s. 1413-1422 ISSN 1616-5187 R&D Projects: GA ČR GAP205/12/1702; GA ČR GAP106/12/1451; GA ČR GAP503/10/0664; GA ČR GBP205/12/G118 Institutional research plan: CEZ:AV0Z40500505 Institutional support: RVO:61389013 Keywords : affinity biosensors * blood plasma * cerebrospinal fluid Subject RIV: CD - Macromolecular Chemistry Impact factor: 3.742, year: 2012

  17. Application of biological design criteria and computational fluid dynamics to investigate fish survival in Kaplan turbines

    Energy Technology Data Exchange (ETDEWEB)

    Garrison, Laura A. [Voith Siemens Hydro Power Generation, Inc., York, PA (United States); Fisher, Jr., Richard K. [Voith Siemens Hydro Power Generation, Inc., York, PA (United States); Sale, Michael J. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Cada, Glenn [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States)

    2002-07-01

    One of the contributing factors to fish injury in a turbine environment is shear stress. This paper presents the use of computational fluid dynamics (CFD) to display and quantify areas of elevated shear stress in the Wanapum Kaplan turbine operating at four different flow conditions over its operating range. CFD observations will be compared to field test observations at the same four flow conditions. Methods developed here could be used to facilitate the design of turbines and related water passages with lower risks of fish injury.

  18. Physics of Non-Newtonian Fluids and Interdisciplinary Relations (Biology and Criminology)

    Science.gov (United States)

    Holubova, R.

    2018-01-01

    The aim of the paper is the presentation of an interdisciplinary topic that allows applying content knowledge in physics, mathematics and biology in real life environment. Students use to play games and view crime scenes but in common they have little knowledge about the science used during crime scene investigation. In this paper the science…

  19. Correlative analysis of metabolite profiling of Danggui Buxue Tang in rat biological fluids by rapid resolution LC-TOF/MS.

    Science.gov (United States)

    Li, Chang-Yin; Qi, Lian-Wen; Li, Ping

    2011-04-28

    In this work, the metabolite profiles of Danggui Buxue Tang (DBT) in rat bile and plasma were qualitatively described, and the possible metabolic pathways of DBT were subsequently proposed. Emphasis was put on correlative analysis of metabolite profiling in different biological fluids. After oral administration of DBT, bile and plasma samples were collected and pretreated by solid phase extraction. Rapid resolution liquid chromatography coupled to time-of-flight mass spectrometry (RRLC-TOFMS) was used for characterization of DBT-related compounds (parent compounds and metabolites) in biological matrices. A total of 142 metabolites were detected and tentatively identified from the drug-containing bile and plasma samples. Metabolite profiling shows that rat bile contained relatively more glutathione-derived conjugates, more saponins compounds and more diverse forms of metabolites than urine. The metabolite profile in plasma revealed that glucuronide conjugates of isoflavonoids, dimmers, acetylcysteine conjugates and parent form of phthalides, as well as saponin aglycones were the major circulating forms of DBT. Collectively, the metabolite profile analysis of DBT in different biological matrices provided a comprehensive understanding of the in vivo metabolic fates of constituents in DBT. Copyright © 2011 Elsevier B.V. All rights reserved.

  20. Restricted access materials and large particle supports for on-line sample preparation: an attractive approach for biological fluids analysis.

    Science.gov (United States)

    Souverain, S; Rudaz, S; Veuthey, J-L

    2004-03-05

    An analytical process generally involves four main steps: (1) sample preparation; (2) analytical separation; (3) detection; and (4) data handling. In the bioanalytical field, sample preparation is often considered as the time-limiting step. Indeed, the extraction techniques commonly used for biological matrices such as liquid-liquid extraction (LLE) and solid-phase extraction (SPE) are achieved in the off-line mode. In order to perform a high throughput analysis, efforts have been engaged in developing a faster sample purification process. Among different strategies, the introduction of special extraction sorbents, such as the restricted access media (RAM) and large particle supports (LPS), allowing the direct and repetitive injection of complex biological matrices, represents a very attractive approach. Integrated in a liquid chromatography (LC) system, these extraction supports lead to the automation, simplification and speeding up of the sample preparation process. In this paper, RAM and LPS are reviewed and particular attention is given to commercially available supports. Applications of these extraction supports, are presented in single column and column-switching configurations, for the direct analysis of compounds in various biological fluids.

  1. Electromembrane extraction as a rapid and selective miniaturized sample preparation technique for biological fluids

    DEFF Research Database (Denmark)

    Gjelstad, Astrid; Pedersen-Bjergaard, Stig; Seip, Knut Fredrik

    2015-01-01

    This special report discusses the sample preparation method electromembrane extraction, which was introduced in 2006 as a rapid and selective miniaturized extraction method. The extraction principle is based on isolation of charged analytes extracted from an aqueous sample, across a thin film....... Technical aspects of electromembrane extraction, important extraction parameters as well as a handful of examples of applications from different biological samples and bioanalytical areas are discussed in the paper....

  2. Interaction of uranium(VI) with bioligands present in human biological fluids. The case study of urea and uric acid

    Energy Technology Data Exchange (ETDEWEB)

    Osman, A.A.A.; Geipel, G.; Bernhard, G. [Helmholtz-Zentrum Dresden-Rossendorf, Dresden (Germany). Inst. of Resource Ecology

    2013-05-01

    The complexation of uranium(VI) with bioligands found in human biological fluids, viz, urea and uric acid in aqueous solutions, has been investigated using time-resolved laser-induced fluorescence spectroscopy (TRLFS) at room temperature, I = 0.1 M (NaClO4) and pH (3 for uric acid; 4 for urea). In both complex systems a static quench effect with increasing ligand concentration and no peaks shift upon complexation were observed. With uranium(VI) both ligands formed a fairly weak 1:1 complex with average stability constants of log {beta}{sub 110} = 4.67 {+-} 0.29 for uric acid and log {beta}{sub 110} = 3.79 {+-} 0.15 and 2.12 {+-} 0.18 for relatively low and relatively high urea concentrations, respectively. Application of the newly generated data on the U(VI) speciation modelling in biofluids, e.g., human urine was also discussed.

  3. Interaction of uranium(VI) with bioligands present in human biological fluids. The case study of urea and uric acid

    International Nuclear Information System (INIS)

    Osman, A.A.A.; Geipel, G.; Bernhard, G.

    2013-01-01

    The complexation of uranium(VI) with bioligands found in human biological fluids, viz, urea and uric acid in aqueous solutions, has been investigated using time-resolved laser-induced fluorescence spectroscopy (TRLFS) at room temperature, I = 0.1 M (NaClO4) and pH (3 for uric acid; 4 for urea). In both complex systems a static quench effect with increasing ligand concentration and no peaks shift upon complexation were observed. With uranium(VI) both ligands formed a fairly weak 1:1 complex with average stability constants of log β 110 = 4.67 ± 0.29 for uric acid and log β 110 = 3.79 ± 0.15 and 2.12 ± 0.18 for relatively low and relatively high urea concentrations, respectively. Application of the newly generated data on the U(VI) speciation modelling in biofluids, e.g., human urine was also discussed.

  4. Development and evaluation of a radioimmunoassay for the detection of amphetamine and related compounds in biological fluids

    International Nuclear Information System (INIS)

    Mason, P.A.; Bal, T.S.; Law, B.; Moffat, A.C.

    1983-01-01

    A radioimmunoassay has been developed for the detection of amphetamine and its analogues in blood and urine without any pretreatment of the samples. It is based on a commercially available antiserum and a [ 125 I] iodinated derivative of amphetamine. The assay can detect low levels of amphetamine (less than 10 ng ml - 1 ) in very small samples (50 μl) of blood and urine. It is cheap (3 pence per test), rapid, simple to perform and is specific for compounds closely related to amphetamine. A high, positive correlation was obtained (r = 0.93) when results of the analyses of urine samples from volunteers who had ingested amphetamine were compared with those produced by gas chromatography - mass spectrometry. The assay has proved very useful for the detection of amphetamine and closely related compounds in biological fluids. (author)

  5. Measurement of total CO2 in microliter samples of urine and other biological fluids using infrared detection of CO2.

    Science.gov (United States)

    Trepiccione, Francesco; Iena, Francesco Maria; Catalini, Laura; Carpi, Francesco Martino; Koed, Mogens; Frische, Sebastian

    2017-10-01

    The purpose of this study is to describe a low-cost and simply made instrument capable of measuring the total CO 2 content of microliter volumes of biological fluids utilizing a commercially available CO 2 sensor based on a NDIR detector. The described instrument is based on transformation of dissolved HCO 3 - to CO 2 by acidification and subsequent measurement of the produced CO 2 . The instrument has a linear response in the range 0.025-10 μmol HCO 3 - , which enables measurements in fresh urine and plasma samples down to 5 μl. The values from plasma were compared to measurements made on 65 μl whole blood in an automatic blood gas analyzer and found not to differ significantly. Compared to currently commercially available instruments applying the same principles to measure total CO 2 , this study provides a simple and robust alternative which even can be used on smaller sample volumes.

  6. High-performance liquid chromatographic assay for acetaminophen and phenacetin in the presence of their metabolites in biological fluids

    International Nuclear Information System (INIS)

    Pang, K.S.; Taburet, A.M.; Hinson, J.A.; Gillette, J.R.

    1979-01-01

    The authors propose a method in which tracer amounts of a radiolabeled compound are used as the internal standard for the same unlabeled compound in high-performance liquid chromatography. The approach is valuable when a response from the internal standard becomes undesirable due to the presence of interference by the metabolites. The authors tested their approach with phenacetin and its metabolites, 2-hydroxyphenacetin, N-hydroxyphenacetin, phenetidine, acetaminophen sulfate conjugate and acetaminophen glucuronide conjugate in biological fluids with the use of [ 14 C] phenacetin and [ 3 H] acetaminophen as the internal standards, and were able to quantitate both phenacetin and acetaminophen simultaneously. They also tested the alternative approach in which the unlabeled drug was used as internal standard for tracer amounts of the same radiolabeled compound, with phenacetin and acetaminophen as the internal standards for tracer amounts of [ 14 C] phenacetin and [ 3 H] acetaminophen. Again, they were able to quantiate the two tracer radiolabeled compounds simultaneously. (Auth.)

  7. Bioprocess scale-up/down as integrative enabling technology: from fluid mechanics to systems biology and beyond.

    Science.gov (United States)

    Delvigne, Frank; Takors, Ralf; Mudde, Rob; van Gulik, Walter; Noorman, Henk

    2017-09-01

    Efficient optimization of microbial processes is a critical issue for achieving a number of sustainable development goals, considering the impact of microbial biotechnology in agrofood, environment, biopharmaceutical and chemical industries. Many of these applications require scale-up after proof of concept. However, the behaviour of microbial systems remains unpredictable (at least partially) when shifting from laboratory-scale to industrial conditions. The need for robust microbial systems is thus highly needed in this context, as well as a better understanding of the interactions between fluid mechanics and cell physiology. For that purpose, a full scale-up/down computational framework is already available. This framework links computational fluid dynamics (CFD), metabolic flux analysis and agent-based modelling (ABM) for a better understanding of the cell lifelines in a heterogeneous environment. Ultimately, this framework can be used for the design of scale-down simulators and/or metabolically engineered cells able to cope with environmental fluctuations typically found in large-scale bioreactors. However, this framework still needs some refinements, such as a better integration of gas-liquid flows in CFD, and taking into account intrinsic biological noise in ABM. © 2017 The Authors. Microbial Biotechnology published by John Wiley & Sons Ltd and Society for Applied Microbiology.

  8. Single lipid vesicle assay for characterizing single-enzyme kinetics of phospholipid hydrolysis in a complex biological fluid.

    Science.gov (United States)

    Tabaei, Seyed R; Rabe, Michael; Zetterberg, Henrik; Zhdanov, Vladimir P; Höök, Fredrik

    2013-09-25

    Imaging of individual lipid vesicles is used to track single-enzyme kinetics of phospholipid hydrolysis. The method is employed to quantify the catalytic activity of phospholipase A2 (PLA2) in both pure and complex biological fluids. The measurements are demonstrated to offer a subpicomolar limit of detection (LOD) of human secretory PLA2 (sPLA2) in up to 1000-fold-diluted cerebrospinal fluid (CSF). An additional new feature provided by the single-enzyme sensitivity is that information about both relative concentration variations of active sPLA2 in CSF and the specific enzymatic activity can be simultaneously obtained. When CSF samples from healthy controls and individuals diagnosed with Alzheimer's disease (AD) are analyzed, the specific enzymatic activity is found to be preserved within 7% in the different CSF samples whereas the enzyme concentration differs by up to 56%. This suggests that the previously reported difference in PLA2 activity in CSF samples from healthy and AD individuals originates from differences in the PLA2 expression level rather than from the enzyme activity. Conventional ensemble averaging methods used to probe sPLA2 activity do not allow one to obtain such information. Together with an improvement in the LOD of at least 1 order of magnitude compared to that of conventional assays, this suggests that the method will become useful in furthering our understanding of the role of PLA2 in health and disease and in detecting the pharmacodynamic effects of PLA2-targeting drug candidates.

  9. Direct deposition of gas phase generated aerosol gold nanoparticles into biological fluids--corona formation and particle size shifts.

    Directory of Open Access Journals (Sweden)

    Christian R Svensson

    Full Text Available An ongoing discussion whether traditional toxicological methods are sufficient to evaluate the risks associated with nanoparticle inhalation has led to the emergence of Air-Liquid interface toxicology. As a step in this process, this study explores the evolution of particle characteristics as they move from the airborne state into physiological solution. Airborne gold nanoparticles (AuNP are generated using an evaporation-condensation technique. Spherical and agglomerate AuNPs are deposited into physiological solutions of increasing biological complexity. The AuNP size is characterized in air as mobility diameter and in liquid as hydrodynamic diameter. AuNP:Protein aggregation in physiological solutions is determined using dynamic light scattering, particle tracking analysis, and UV absorption spectroscopy. AuNPs deposited into homocysteine buffer form large gold-aggregates. Spherical AuNPs deposited in solutions of albumin were trapped at the Air-Liquid interface but was readily suspended in the solutions with a size close to that of the airborne particles, indicating that AuNP:Protein complex formation is promoted. Deposition into serum and lung fluid resulted in larger complexes, reflecting the formation of a more complex protein corona. UV absorption spectroscopy indicated no further aggregation of the AuNPs after deposition in solution. The corona of the deposited AuNPs shows differences compared to AuNPs generated in suspension. Deposition of AuNPs from the aerosol phase into biological fluids offers a method to study the protein corona formed, upon inhalation and deposition in the lungs in a more realistic way compared to particle liquid suspensions. This is important since the protein corona together with key particle properties (e.g. size, shape and surface reactivity to a large extent may determine the nanoparticle effects and possible translocation to other organs.

  10. Direct Deposition of Gas Phase Generated Aerosol Gold Nanoparticles into Biological Fluids - Corona Formation and Particle Size Shifts

    Science.gov (United States)

    Svensson, Christian R.; Messing, Maria E.; Lundqvist, Martin; Schollin, Alexander; Deppert, Knut; Pagels, Joakim H.; Rissler, Jenny; Cedervall, Tommy

    2013-01-01

    An ongoing discussion whether traditional toxicological methods are sufficient to evaluate the risks associated with nanoparticle inhalation has led to the emergence of Air-Liquid interface toxicology. As a step in this process, this study explores the evolution of particle characteristics as they move from the airborne state into physiological solution. Airborne gold nanoparticles (AuNP) are generated using an evaporation-condensation technique. Spherical and agglomerate AuNPs are deposited into physiological solutions of increasing biological complexity. The AuNP size is characterized in air as mobility diameter and in liquid as hydrodynamic diameter. AuNP:Protein aggregation in physiological solutions is determined using dynamic light scattering, particle tracking analysis, and UV absorption spectroscopy. AuNPs deposited into homocysteine buffer form large gold-aggregates. Spherical AuNPs deposited in solutions of albumin were trapped at the Air-Liquid interface but was readily suspended in the solutions with a size close to that of the airborne particles, indicating that AuNP:Protein complex formation is promoted. Deposition into serum and lung fluid resulted in larger complexes, reflecting the formation of a more complex protein corona. UV absorption spectroscopy indicated no further aggregation of the AuNPs after deposition in solution. The corona of the deposited AuNPs shows differences compared to AuNPs generated in suspension. Deposition of AuNPs from the aerosol phase into biological fluids offers a method to study the protein corona formed, upon inhalation and deposition in the lungs in a more realistic way compared to particle liquid suspensions. This is important since the protein corona together with key particle properties (e.g. size, shape and surface reactivity) to a large extent may determine the nanoparticle effects and possible translocation to other organs. PMID:24086363

  11. Biological changes of APA-BCC analgesic microcapsule in cerebrospinal fluid of patients with carcinomatous pain

    International Nuclear Information System (INIS)

    Luo Yun; Li Yanling; Xue Yilong; Guo Shulong; Gao Yuhong; Cui Xin

    2005-01-01

    To explore the changes of alginate-polylysine-alginate microcapsulated bovine adrenal medullary chromaffin cells (APA-BCC microcapsules) in morphology, survival rate and leucine- enkephalin secretion after they were transplanted into CSF of cancerpain patients, the APA- BCC microcapsules were Implanted into cavitas subarachnoidealis of cancer-pain patients by conventional lumbar puncture. After 7 or 8 days, cerebrospinal fluid was collected and the morphology of the APA-BCC microcapsule, the survival rate of cells were observed and secretory volume of leucine-enkephalin was assayed by radioimmunity method. Seven days after trans- plantation, the mean VAS decreased from 8.8 to 2.4, the survival rate of cells averagely reduced from 91.2% to 89.1%, morphology of APA-BCC microcapsules did not change obviously and secretory volume of leucine-enkephalin went up 1.65 times compared with that at pretrans- plantation. In conclusion, APA-BCC can survive, secret leucine-enkephalin and produce analgesic effect after transplanted into CSF of cancer-patients. (authors)

  12. Analytical Strategies for the Determination of Norepinephrine Reuptake Inhibitors in Pharmaceutical Formulations and Biological Fluids.

    Science.gov (United States)

    Saka, Cafer

    2016-01-01

    Norepinephrine reuptake inhibitors (NRIs) are a class of antidepressant drugs that act as reuptake inhibitors for the neurotransmitters norepinephrine and epinephrine. The present review provides an account of analytical methods published in recent years for the determination of NRI drugs. NRIs are atomoxetine, reboxetine, viloxazine and maprotiline. NRIs with less activity at other sites are mazindol, bupropion, tapentadol, and teniloxazine. This review focuses on the analytical methods including chromatographic, spectrophotometric, electroanalytical, and electrophoresis techniques for NRI analysis from pharmaceutical formulations and biological samples. Among all of the published methods, liquid chromatography with UV-vis or MS-MS detection is the most popular technique. The most the common sample preparation techniques in the analytical methods for NRIs include liquid-liquid extraction and solid-phase extraction. Besides the analytical methods for single components, some of the simultaneous determinations are also included in this review.

  13. ACTIVITY OF NATURAL KILLER CELLS IN BIOLOGICAL FLUIDS FROM PATIENTS WITH COLORECTAL AND OVARIAN CANCERS

    Directory of Open Access Journals (Sweden)

    N. V. Yunusova

    2017-01-01

    Full Text Available Objective. To compare the functional activity of natural killer cells in peripheral blood and ascites from patients with different stages of colorectal and ovarian cancers and benign ovarian tumors. Material and methods. The study included 10 patients with stage IIIC ovarian cancer (FIGO, 2009, 5 patients with benign ovarian tumors (BOTs, and 15 patients with colorectal cancer (T2–4N0–2M0 . The control group consisted of 5 healthy donors. To evaluate the number and functional activity of NK-cells in peripheral blood and ascites, the FACS Canto II Flow Cytometer was used. Results. In peripheral blood of patients with ovarian and colorectal cancers, the relative number of activated NK-cells capable of secreting granzyme B (GB (CD56 + CD107a + GB + PF- was significantly lower and the proportion of degranulated NK-cells (CD56 + CD107a + GB- PF- was higher than those of healthy donors. Low total NK-cell counts in peripheral blood were a distinctive feature of ovarian cancer patients (p<0.05. The proportion of activated peripheral blood NK-cells, containing granules of cytolytic enzymes GB and perforin (PF increased with tumor growth. However, lymph node metastasis in patients with colorectal cancer did not affect the level and activation of NK-cells. The comparative analysis of NK-populations in patients with benign and malignant ovarian tumors revealed that the level of CD56 + cells was significantly higher in tumor ascites compared to peripheral blood. In patients with BTs, the levels of CD56 + CD107a + and activated CD56 + CD107a + GB-PF-degranulated cells was higher in ascites than in blood. In patients with ovarian cancer, the level of degranulated cells was higher in peripheral blood than in malignant ascites. Conclusion. The tumor cells and tumor microenvironment were found to affect the number and the functional activity of NK-cells. The accumulation of free fluid within the peritoneal cavity in patients with both benign and malignant

  14. Supercritical Fluid Extraction and Ultra Performance Liquid Chromatography of Respiratory Quinones for Microbial Community Analysis in Environmental and Biological Samples

    Directory of Open Access Journals (Sweden)

    Koichi Fujie

    2012-03-01

    Full Text Available Microbial community structure plays a significant role in environmental assessment and animal health management. The development of a superior analytical strategy for the characterization of microbial community structure is an ongoing challenge. In this study, we developed an effective supercritical fluid extraction (SFE and ultra performance liquid chromatography (UPLC method for the analysis of bacterial respiratory quinones (RQ in environmental and biological samples. RQ profile analysis is one of the most widely used culture-independent tools for characterizing microbial community structure. A UPLC equipped with a photo diode array (PDA detector was successfully applied to the simultaneous determination of ubiquinones (UQ and menaquinones (MK without tedious pretreatment. Supercritical carbon dioxide (scCO2 extraction with the solid-phase cartridge trap proved to be a more effective and rapid method for extracting respiratory quinones, compared to a conventional organic solvent extraction method. This methodology leads to a successful analytical procedure that involves a significant reduction in the complexity and sample preparation time. Application of the optimized methodology to characterize microbial communities based on the RQ profile was demonstrated for a variety of environmental samples (activated sludge, digested sludge, and compost and biological samples (swine and Japanese quail feces.

  15. Supercritical fluid extraction and ultra performance liquid chromatography of respiratory quinones for microbial community analysis in environmental and biological samples.

    Science.gov (United States)

    Hanif, Muhammad; Atsuta, Yoichi; Fujie, Koichi; Daimon, Hiroyuki

    2012-03-05

    Microbial community structure plays a significant role in environmental assessment and animal health management. The development of a superior analytical strategy for the characterization of microbial community structure is an ongoing challenge. In this study, we developed an effective supercritical fluid extraction (SFE) and ultra performance liquid chromatography (UPLC) method for the analysis of bacterial respiratory quinones (RQ) in environmental and biological samples. RQ profile analysis is one of the most widely used culture-independent tools for characterizing microbial community structure. A UPLC equipped with a photo diode array (PDA) detector was successfully applied to the simultaneous determination of ubiquinones (UQ) and menaquinones (MK) without tedious pretreatment. Supercritical carbon dioxide (scCO(2)) extraction with the solid-phase cartridge trap proved to be a more effective and rapid method for extracting respiratory quinones, compared to a conventional organic solvent extraction method. This methodology leads to a successful analytical procedure that involves a significant reduction in the complexity and sample preparation time. Application of the optimized methodology to characterize microbial communities based on the RQ profile was demonstrated for a variety of environmental samples (activated sludge, digested sludge, and compost) and biological samples (swine and Japanese quail feces).

  16. Lipidomic analysis of biological samples: Comparison of liquid chromatography, supercritical fluid chromatography and direct infusion mass spectrometry methods.

    Science.gov (United States)

    Lísa, Miroslav; Cífková, Eva; Khalikova, Maria; Ovčačíková, Magdaléna; Holčapek, Michal

    2017-11-24

    Lipidomic analysis of biological samples in a clinical research represents challenging task for analytical methods given by the large number of samples and their extreme complexity. In this work, we compare direct infusion (DI) and chromatography - mass spectrometry (MS) lipidomic approaches represented by three analytical methods in terms of comprehensiveness, sample throughput, and validation results for the lipidomic analysis of biological samples represented by tumor tissue, surrounding normal tissue, plasma, and erythrocytes of kidney cancer patients. Methods are compared in one laboratory using the identical analytical protocol to ensure comparable conditions. Ultrahigh-performance liquid chromatography/MS (UHPLC/MS) method in hydrophilic interaction liquid chromatography mode and DI-MS method are used for this comparison as the most widely used methods for the lipidomic analysis together with ultrahigh-performance supercritical fluid chromatography/MS (UHPSFC/MS) method showing promising results in metabolomics analyses. The nontargeted analysis of pooled samples is performed using all tested methods and 610 lipid species within 23 lipid classes are identified. DI method provides the most comprehensive results due to identification of some polar lipid classes, which are not identified by UHPLC and UHPSFC methods. On the other hand, UHPSFC method provides an excellent sensitivity for less polar lipid classes and the highest sample throughput within 10min method time. The sample consumption of DI method is 125 times higher than for other methods, while only 40μL of organic solvent is used for one sample analysis compared to 3.5mL and 4.9mL in case of UHPLC and UHPSFC methods, respectively. Methods are validated for the quantitative lipidomic analysis of plasma samples with one internal standard for each lipid class. Results show applicability of all tested methods for the lipidomic analysis of biological samples depending on the analysis requirements

  17. Use of charged particle beams for analysis of biological tissues and fluids

    International Nuclear Information System (INIS)

    Campbell, J.L.

    1983-01-01

    PIXE has passed through its demonstration stage and matured into a viable tool supported by a reliable physics data base; the main problem to be solved at the outset of any new project is the preparation of a representative specimen of uniform thickness (or thinness) rather than any aspect of X-ray or accelerator physics or technology. The authors repeats the caution that minimum detection limits are strongly influenced by the nuclear reaction gamma-ray background from trace elements in the specimen. Thus experiment on a new target type is preferable to use of MDL calculations based on the background due to atomic processes (bremsstrahlung) in the known matrix. One hopes to see a more adventurous mood eg a move from routine blood serum analysis towards analyses of different blood fractions that concentrate specific trace elements. PIGE, while promising, must be regarded as developmental until the data-base of elemental gamma-ray yields is extended and made more accurate; work on fluorine in teeth clearly stands to profit from this technique. Finally, RBS, although scarcely used to date in any biological context, is clearly a powerful way of measuring major elemental ratios in mineralized tissues; however, RBS lacks the resolving power of PIXE and so is not a candidate for multi-trace element analysis

  18. A new fluid dynamics model to evaluate the contractile force of a biological spring, Vorticella convallaria

    Science.gov (United States)

    Ryu, Sangjin; Matsudaira, Paul

    2008-11-01

    Vorticella convallaria, a sessile peritrich having a body and spring-like stalk, is a model for a bioinspired actuator because of its remarkably fast (msec) and powerful contractions (nN). An example of a biological spring, the stalk converts biochemical energy to physical motion, but the mechanics of contraction are poorly understood. To evaluate contraction force, past models have assumed the body to be a sphere moving in quiescent water and have equated contraction force to drag force on the body described by Stokes' law. However, flow induced by contracting Vorticella does not satisfy conditions of Stokes' law because the flow is unsteady (Womersley number > 1) and bound with a solid substrate to which the cell is tethered. We develop a more rigorous model for contraction force evaluation by assuming the body to be a sphere unsteadily moving perpendicularly toward a solid surface. The model comprises quasi-steady drag force, added mass force and history force with wall effect correction terms for each force. Vorticella not only generates a maximum contraction force greater than Stokes' drag, but it also experiences drag force in the direction of contraction in the later stage of contraction due to the memory effect of water.

  19. Analysis of S-35 labeled WR-2721 and its metabolites in biological fluids

    International Nuclear Information System (INIS)

    Anderson, K.W.; Krohn, K.A.; Grunbaum, Z.; Phillips, R.B.; Mahler, P.A.; Menard, T.W.; Spence, A.M.; Rasey, J.S.

    1984-01-01

    Studies with WR-2721 and related compounds have been hindered by the lack of a suitable assay for the drug and its major metabolites. A chromatographic method which requires no derivation for the separation and detection of WR-2721, the free thiol, its symmetrical disulfide and other mixed disulfides has been developed. The procedure involves ion-pairing for separation of ionizable compounds by causing polar molecules to become more lipophilic and hence separable using reverse phase HPLC. Detection is based upon liquid scintillation counting of S-35 incorporated during the synthesis of the parent compound. This method requires no pre-column preparation of samples and, by detecting the S-35 label, eliminates the chance that a coeluting species could interfere with detection, as might occur with post-column derivatization. This analytical technique employing radiotracers can be used to study radioprotective mechanisms by time dependent measurements of the tissue distribution and chemical form of labeled drug. Such chemical information can then be correlated with biological measures of radiation protection

  20. No biological evidence of XMRV in blood or prostatic fluid from prostate cancer patients.

    Directory of Open Access Journals (Sweden)

    Ramon Mendoza

    Full Text Available XMRV (xenotropic murine leukemia virus-related virus was initially discovered in association with prostate cancer and later with chronic fatigue syndrome (CFS. Its association with CFS is now largely discredited, and current results support a laboratory origin for XMRV with no reproducible evidence for infection of humans. However, some results indicating the presence of XMRV in prostate cancer are difficult to attribute to sample contamination. Here we have sought biological evidence that might confirm the presence of XMRV in prostate cancer samples previously having tested positive.We have tested for infectious XMRV and neutralizing antibodies against XMRV in blood plasma from 29 subjects with prostate cancer, and for infectious XMRV in prostate secretions from another five prostate cancer subjects. Nine of these subjects had previously tested positive for XMRV by PCR or by virus assay. We did not detect XMRV or related retroviruses in any sample, and the neutralizing activities of the plasma samples were all very low, a result inconsistent with XMRV infection of the plasma donors.We find no evidence for XMRV infection of any human subject tested, either by assay for infectious virus or for neutralizing antibodies. Our results are consistent with the majority of published studies on XMRV, which find that XMRV is not present in humans. The observed low to undetectable XMRV neutralization by human plasma indicates a lack of innate restriction of XMRV replication by soluble factors in human blood.

  1. [Determination of ethylene glycol in biological fluids--propylene glycol interferences].

    Science.gov (United States)

    Gomółka, Ewa; Cudzich-Czop, Sylwia; Sulka, Adrianna

    2013-01-01

    Many laboratories in Poland do not use gas chromatography (GC) method for determination of ethylene glycol (EG) and methanol in blood of poisoned patients, they use non specific spectrophotometry methods. One of the interfering substances is propylene glycol (PG)--compound present in many medical and cosmetic products: drops, air freshens, disinfectants, electronic cigarettes and others. In Laboratory of Analytical Toxicology and Drug Monitoring in Krakow determination of EG is made by GC method. The method enables to distinguish and make resolution of (EG) and (PG) in biological samples. In the years 2011-2012 in several serum samples from diagnosed patients PG was present in concentration from several to higher than 100 mg/dL. The aim of the study was to estimate PG interferences of serum EG determination by spectrophotometry method. Serum samples containing PG and EG were used in the study. The samples were analyzed by two methods: GC and spectrophotometry. Results of serum samples spiked with PG with no EG analysed by spectrophotometry method were improper ("false positive"). The results were correlated to PG concentration in samples. Calculated cross-reactivity of PG in the method was 42%. Positive results of EG measured by spectrophotometry method must be confirmed by reference GC method. Spectrophotometry method shouldn't be used for diagnostics and monitoring of patients poisoned by EG.

  2. Determination of parathion in biological fluids by means of direct solid-phase microextraction.

    Science.gov (United States)

    Gallardo, E; Barroso, M; Margalho, C; Cruz, A; Vieira, D N; López-Rivadulla, M

    2006-11-01

    A new and simple procedure for the determination of parathion in human whole blood and urine using direct immersion (DI) solid-phase microextraction (SPME) and gas chromatography/mass spectrometry (GC/MS) is presented. This technique was developed using only 100 microL of sample, and ethion was used as internal standard (IS). A 65-microm Carbowax/divinylbenzene (CW/DVB) SPME fibre was selected for sampling, and the main parameters affecting the SPME process such as extraction temperature, adsorption and desorption time, salt addition, agitation and pH effect were optimized to enhance the sensitivity of the method. This optimization was also performed to allow the qualitative determination of parathion's main metabolite, paraoxon, in blood. The limits of detection and quantitation for parathion were 3 and 10 ng/mL for urine and 25 and 50 ng/mL for blood, respectively. For paraoxon, the limit of detection was 50 ng/mL in blood. The method showed linearity between the LOQ and 50 microg/mL for both matrices, with correlation coefficients ranging from 0.9954 to 0.9999. Precision and accuracy were in conformity with the criteria normally accepted in bioanalytical method validation. The mean absolute recoveries were 35.1% for urine and 6.7% for blood. Other parameters such as dilution of sample and stability were also validated. Its simplicity and the fact that only 100 microL of sample is required to accomplish the analysis make this method useful in forensic toxicology laboratories to determine this compound in intoxications, and it can be considered an alternative to other methods normally used for the determination of this compound in biological media.

  3. Determination of cyclodextrins in biological fluids by high-performance liquid chromatography with negative colorimetric detection using post-column complexation with phenolphthalein

    NARCIS (Netherlands)

    Frijlink, H.W.; Visser, J.; Drenth, B.F.H.

    1987-01-01

    A rapid and sensitive high-performance liquid chromatographic method for the analysis of beta- and gamma-cyclodextrin in aqueous biological fluids such as plasma, urine, or tissue homogenate is described. The chromatographic system consists of a microBondapak Phenyl column as stationary phase and a

  4. Generation of monoclonal antibodies and development of an immunofluorometric assay for the detection of CUZD1 in tissues and biological fluids.

    Science.gov (United States)

    Farkona, Sofia; Soosaipillai, Antoninus; Filippou, Panagiota; Korbakis, Dimitrios; Serra, Stefano; Rückert, Felix; Diamandis, Eleftherios P; Blasutig, Ivan M

    2017-12-01

    CUB and zona pellucida-like domain-containing protein 1 (CUZD1) was identified as a pancreas-specific protein and was proposed as a candidate biomarker for pancreatic related disorders. CUZD1 protein levels in tissues and biological fluids have not been extensively examined. The purpose of the present study was to generate specific antibodies targeting CUZD1 to assess CUZD1 expression within tissues and biological fluids. Mouse monoclonal antibodies against CUZD1 were generated and used to perform immunohistochemical analyses and to develop a sensitive and specific enzyme-linked immunosorbent assay (ELISA). CUZD1 protein expression was assessed in various human tissue extracts and biological fluids and in gel filtration chromatography-derived fractions of pancreatic tissue extract, pancreatic juice and recombinant protein. Immunohistochemical staining of CUZD1 in pancreatic tissue showed that the protein is localized to the acinar cells and the lumen of the acini. Western blot analysis detected the protein in pancreatic tissue extract and pancreatic juice. The newly developed ELISA measured CUZD1 in high levels in pancreas and in much lower but detectable levels in several other tissues. In the biological fluids tested, CUZD1 expression was detected exclusively in pancreatic juice. The analysis of gel filtration chromatography-derived fractions of pancreatic tissue extract, pancreatic juice and recombinant CUZD1 suggested that the protein exists in high molecular weight protein complexes. This study describes the development of tools targeting CUZD1 protein, its tissue expression pattern and levels in several biological fluids. These new tools will facilitate future investigations aiming to delineate the role of CUZD1 in physiology and pathobiology. Copyright © 2017 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  5. Miniaturized ionophore-based potentiometric sensors for the flow-injection determination of metformin in pharmaceutical formulations and biological fluids.

    Science.gov (United States)

    Khaled, Elmorsy; Kamel, Manal S; Hassan, Hassan N; Abd El-Alim, Sameh H; Aboul-Enein, Hassan Y

    2012-12-07

    Miniaturized potentiometric sensors based on β-cyclodextrins (β-CDs) are described for determination of metformin (Mf) in pharmaceutical preparations and biological fluids. Electrode matrix compositions are optimized on the basis of the nature and content of sensing ionophore, ionic sites and plasticizers. Coated wire electrodes (CWEs) modified with heptakis(2,3,6-tri-O-methyl)-β-CD, sodium tetrakis(4-fluorophenyl)borate (NaTFPB) and 2-fluorophenyl 2-nitrophenyl ether (f-NPE), work satisfactorily in the concentration range from 10(-6) to 10(-1) mol L(-1) with Nernstian compliance (55.7 ± 0.4 mV per decade activity) and a detection limit of 8 × 10(-7) mol L(-1). Incorporation of β-CD as a molecular recognition element improved the electrode sensitivity and selectivity due to encapsulation of Mf into the β-CD cavity (host-guest interaction). The developed electrodes have been successfully applied for the potentiometric determination of Mf under batch and flow injection analysis (FIA). FIA allows analysis of 90 samples per h offering the advantages of simplicity, accuracy and automation feasibility. The dissolution profile for metformin pharmaceutical samples (Cidophage®) was monitored using the proposed electrode in comparison with the official spectrophotometric methods. Characterization of the formed Mf-β-CD inclusion complexes is discussed in detail.

  6. Site-specific distribution of claudin-based paracellular channels with roles in biological fluid flow and metabolism.

    Science.gov (United States)

    Tanaka, Hiroo; Tamura, Atsushi; Suzuki, Koya; Tsukita, Sachiko

    2017-10-01

    The claudins are a family of membrane proteins with at least 27 members in humans and mice. The extracellular regions of claudin proteins play essential roles in cell-cell adhesion and the paracellular barrier functions of tight junctions (TJs) in epithelial cell sheets. Furthermore, the extracellular regions of some claudins function as paracellular channels in the paracellular barrier that allow the selective passage of water, ions, and/or small organic solutes across the TJ in the extracellular space. Structural analyses have revealed a common framework of transmembrane, cytoplasmic, and extracellular regions among the claudin-based paracellular barriers and paracellular channels; however, differences in the claudins' extracellular regions, such as their charges and conformations, determine their properties. Among the biological systems that involve fluid flow and metabolism, it is noted that hepatic bile flow, renal Na + reabsorption, and intestinal nutrient absorption are dynamically regulated via site-specific distributions of paracellular channel-forming claudins in tissue. Here, we focus on how site-specific distributions of claudin-2- and claudin-15-based paracellular channels drive their organ-specific functions in the liver, kidney, and intestine. © 2017 New York Academy of Sciences.

  7. Determination of the trypanocidal drug melarsoprol and its conversion products in biological fluids with HPLC-ICPMS/ESMS.

    Science.gov (United States)

    Raber, Georg; Raber, Thomas; Raml, Reingard; Murko, Manuela; Magnes, Christoph; Francesconi, Kevin A

    2013-11-15

    Although melarsoprol, an organoarsenic compound, is widely used for the treatment of trypanosomiasis (human African sleeping sickness), very little is known about its fate in the human body, its active metabolites passing the blood-brain barrier and the mode of action. Previous pharmacological studies based on the determination of melarsoprol by HPLC-UV or by a bioassay method produced different results. We report a HPLC-ICPMS method suitable for determining melarsoprol and its metabolites in biological fluids. The arsenic selective capability of the method allowed the quantitative measurement of melarsoprol and two arsenic-containing conversion products produced when melarsoprol was incubated with human serum and blood. The major product was identified as melarsen [4-[(4,6-diamino-1,3,5-triazin-2-yl)amino]phenyl]arsonic acid by HPLC/electrospray MS, and by accurate mass measurements. Investigations about the stability of melarsoprol in serum showed that within 30 h about 10% of melarsoprol is converted to melarsen. In blood, however, most of the melarsoprol was bound to proteins and only 1% was converted to melarsen after 30 hours. The limit of detection for melarsoprol and its conversion products were in the range of 1 µg AsL(-1) (13 nmol As L(-1)) based on signal to noise ratio of 3 with a 10 µL injection volume allowing direct determination of the compounds in blood and serum (after protein precipitation) at therapeutically realistic concentrations. © 2013 Elsevier B.V. All rights reserved.

  8. Spectrofluorimetric determination of buparvaquone in biological fluids, food samples and a pharmaceutical formulation by using terbium-deferasirox probe.

    Science.gov (United States)

    Manzoori, Jamshid L; Jouyban, Abolghasem; Amjadi, Mohammad; Panahi-Azar, Vahid; Karami-Bonari, Amir Reza; Tamizi, Elnaz

    2011-06-15

    A simple spectrofluorimetric method is described for the determination of buparvaquone (BPQ), based on its quenching effect on the fluorescence intensity of Tb(3+)-deferasirox (DFX) complex as a fluorescent probe. The excitation and emission wavelengths were 328 and 545nm, respectively. The optimum conditions for determination of BPQ were investigated considering the effects of various affecting parameters. The variations in fluorescence intensity of the system showed a good linear relationship with the concentration of BPQ in the range of 10-1500μgL(-1), its correlation coefficient was 0.999 with the detection and quantification limits of 1.1 and 3.4μgL(-1), respectively. Linearity, reproducibility, recovery, limits of detection and quantification made the method suitable for BPQ assay in biological fluids, meat, dairy products and BPQ parenteral solutions (vials). The method was applied to real samples of serum and milk of three cows receiving BPQ. Copyright © 2010 Elsevier Ltd. All rights reserved.

  9. Implementation and clinical application of a deformation method for fast simulation of biological tissue formed by fibers and fluid.

    Science.gov (United States)

    Sardinha, Ana Gabriella de Oliveira; Oyama, Ceres Nunes de Resende; de Mendonça Maroja, Armando; Costa, Ivan F

    2016-01-01

    The aim of this paper is to provide a general discussion, algorithm, and actual working programs of the deformation method for fast simulation of biological tissue formed by fibers and fluid. In order to demonstrate the benefit of the clinical applications software, we successfully used our computational program to deform a 3D breast image acquired from patients, using a 3D scanner, in a real hospital environment. The method implements a quasi-static solution for elastic global deformations of objects. Each pair of vertices of the surface is connected and defines an elastic fiber. The set of all the elastic fibers defines a mesh of smaller size than the volumetric meshes, allowing for simulation of complex objects with less computational effort. The behavior similar to the stress tensor is obtained by the volume conservation equation that mixes the 3D coordinates. Step by step, we show the computational implementation of this approach. As an example, a 2D rectangle formed by only 4 vertices is solved and, for this simple geometry, all intermediate results are shown. On the other hand, actual implementations of these ideas in the form of working computer routines are provided for general 3D objects, including a clinical application.

  10. Determination of fetal bile acids in biological fluids from neonates by gas chromatography-negative ion chemical ionization mass spectrometry.

    Science.gov (United States)

    Murai, T; Mahara, R; Kurosawa, T; Kimura, A; Tohma, M

    1997-03-28

    A method has been developed for microanalysis of fetal bile acids in biological fluids from neonates by capillary gas chromatography-mass spectrometry using negative-ion chemical ionization of pentafluorobenzyl ester-dimethylethylsilyl ether derivatives of bile acids. Calibration curves for the bile acid derivatives are useful over the range 0.1-100 pg and the detection limit for bile acids was 1 fg (S/N = 5) using isobutane as a reagent gas. Recoveries of the bile acids and their glycine and taurine conjugates from bile acid-free serum and dried blood discs ranged from 92 to 101% and from 93 to 108%, respectively, of the added amounts of their standard samples. The analysis of bile acids on a dried blood disc, meconium and urine from infants, exhibited significant hydroxylation at the 1 beta-, 2 beta-, 4 beta- and 6 alpha-positions of the usual bile acids, cholic and chenodeoxycholic acids, for the urinary or fecal excretion of bile acids in the fetal and neonatal periods. The present method was applied clinically to analyze bile acids on a dried blood disc from neonatal patients with congenital biliary atresia and hyper-bile-acidemia.

  11. Determination of enalapril maleate and atenolol in their pharmaceutical products and in biological fluids by flow-injection chemiluminescence.

    Science.gov (United States)

    Al-Arfaj, Nawal A; Al-Abdulkareem, Eman A; Aly, Fatma A

    2009-01-01

    A chemiluminescent method using flow injection (FI) was investigated for rapid and sensitive determination of enalapril maleate and atenolol, which are used in the treatment of hypertension. The method is based on the sensitizing effect of these drugs on the Ce(IV)-sulfite reaction. The different experimental parameters affecting the chemiluminescence (CL) intensity were carefully studied and incorporated into the procedure. The method permitted the determination of 0.01-3.0 microg mL(-1) of enalapril maleate in bulk form with correlation coefficient r = 0.99993, lower limit of detection (LOD) 0.0025 microg mL(-1) (S/N = 2) and lower limit of quantitation (LOQ) 0.01 microg mL(-1). The linearity range of atenolol in bulk form was 0.01-2.0 microg mL(-1) (r = 0.99989) with LOD of 0.0003 microg mL(-1) (S/N = 2) and LOQ of 0.01 microg mL(-1). In biological fluids the linearity range of enalapril maleate was 0.1-2.0 microg mL(-1) in both urine and serum, and for atenolol the linearity range was 0.1-1.0 microg mL(-1) in both urine and serum. The method was also applied to the determination of the drugs in their pharmaceutical preparations.

  12. Conventional and planar chip sensors for potentiometric assay of uric acid in biological fluids using flow injection analysis.

    Science.gov (United States)

    Kamel, Ayman H

    2007-10-18

    The potentiometric response properties of several PVC-based membrane sensors using phthalocyanine complexes of cobalt(II) (CoPC) and Fe(II) (FePC) as anion carriers, towards uric acid were constructed and characterized. The sensors demonstrated fast near-Nernstian response for uric acid over the concentration ranges 9.1 x 10(-6) to 9.1 x 10(-2) and 3.1 x 10(-5) to 3.1 x 10(-2)M with detection limits 0.67 and 2.85 microg mL(-1) over pH 6.5-8 for CoPC and FePC based membrane sensors plasticized with o-NPOE and 1% TDMAC, respectively. A novel solid-state planar chip urate sensor was developed, characterized according to IUPAC recommendations, easily used in a single channel wall-jet flow injection system and compared with a tubular detector. The intrinsic characteristics of the detectors in a low dispersion manifold were determined and compared with data obtained under hydrodynamic mode of operation. Validation of the assay methods with the proposed sensors by measuring the lower limit, range, accuracy, precision, repeatability and between-day-variability revealed good performance characteristics confirming applicability for continuous determination of uric acid. The sensors were used for determining urate in biological fluids at an input rate of 50 samples per hour. The results compare favorably with data obtained by the standard spectrophotometry.

  13. A REVIEW ON THE ANALYTICAL TECHNIQUES USED FOR THE DETERMINATION OF PARACETAMOL IN PHARMACEUTICAL FORMULATIONS AND BIOLOGICAL FLUIDS

    Directory of Open Access Journals (Sweden)

    Aisha Noreen

    2016-12-01

    Full Text Available Paracetamol (PM is an active metabolite of phenacetin and belongs to p-aminophenol derivatives. It is also termed as acetaminophen. PM is one of the non-steroidal anti-inflammatory drugs (NSAIDs which is used as an analgesic and antipyretic agent. It is an OTC drug and is used as a common household analgesic. It is not used as a substitute of aspirin or any other NSAIDs. It is a weak cyclooxygenase (COX 1 and 2 inhibitor but may inhibit COX-3 in the central nervous system. Many analytical techniques have been used for the assay of PM in pharmaceutical preparations and biological fluids. These techniques include spectrometry, chromatography, spectrofluorimetry, chemiluminescence, electrochemical techniques, flow injection spectrometry and chronoamperometry. In many pharmaceutical preparations PM is also used in combination with other drugs and these techniques have also been used for their simultaneous determination. A detailed review of various analytical techniques used for the assay of PM has been carried out which would be of great help to the chemists and pharmacists involved in the analysis and quality control of drugs.

  14. Electrochemical oxidation behavior of hydrochlorothiazide on a glassy carbon electrode and its voltammetric determination in pharmaceutical formulations and biological fluids

    Directory of Open Access Journals (Sweden)

    Ali F. Alghamdi

    2014-09-01

    Full Text Available The electrochemical oxidation behavior of hydrochlorothiazide (HCT on a glassy carbon as a working electrode was investigated in Britton–Robinson (B–R buffer pH 3, by using anodic stripping voltammetry (ASV and cyclic voltammetry (CV. This drug gave a well-defined voltammetric oxidation peak at + 1200 mV versus an Ag/AgCl reference electrode. The electrochemical oxidation process was shown to be irreversible and diffusion controlled, with adsorption characterized over the entire pH range. The optimized conditions, such as accumulation time and potential, scan rate, frequency, pulse amplitude, varying of working electrodes, and instrumental parameters were studied. The calibration graph for HCT was obtained from 4 × 10−6 to 4 × 10−5 M (correlation coefficient = 0.997 using the developed electroanalytical method (ASV. The detection limit of this drug was 4.3 × 10−9 M. ASV and CV techniques with adequate precision and accuracy have been developed and applied for direct determination of HCT in commercial tablets without separation or extraction procedures and biological fluids such as urine and plasma.

  15. Micellar HPLC and derivative spectrophotometric methods for the simultaneous determination of fluconazole and tinidazole in pharmaceuticals and biological fluids.

    Science.gov (United States)

    Belal, F; Sharaf El-Din, M K; Eid, M I; El-Gamal, R M

    2014-04-01

    Micellar high-performance liquid chromatography (HPLC) and first-derivative ultraviolet spectrophotometry were used to simultaneously determine fluconazole (FLZ) and tinidazole (TNZ) in combined pharmaceutical dosage forms. The derivative procedure is based on the linear relationship between the drug concentration and the first derivative amplitudes at 220 and 288 nm for FLZ and TNZ, respectively. The calibration graphs were linear in the range of 1.5-9.0 µg/mL for FLZ and 10.0-60.0 µg/mL for TNZ. Furthermore, an HPLC procedure with ultraviolet detection at 210 nm was developed. For the HPLC procedure, good chromatographic separation was achieved using an ODS C18 column (250 × 4.6 mm i.d.). The mobile phase containing 0.15M sodium dodecyl sulphate, 0.3% triethylamine and 12% n-propanol in 0.02M orthophosphoric acid at pH 5.5 was pumped at a flow rate of 1 mL/min. Indapamide was used as an internal standard. The method showed good linearity over the concentration ranges of 1.5-30.0 and 10.0-200.0 µg/mL, with limits of detection of 0.36 and 2.70 µg/mL and limits of quantification of 1.1 and 8.2 µg/mL for FLZ and TNZ, respectively. The suggested methods were successfully applied for the simultaneous analysis of the drugs in their laboratory prepared mixture, co-formulated tablet and single dosage forms. Moreover the second method was also extended to the determination of the drugs in biological fluids.

  16. Tracking problems and possible solutions in the quantitative determination of small molecule drugs and metabolites in biological fluids using liquid chromatography-mass spectrometry.

    Science.gov (United States)

    Bakhtiar, Ray; Majumdar, Tapan K

    2007-01-01

    During the last decade, quantification of low molecular weight molecules using liquid chromatography-tandem mass spectrometry in biological fluids has become a common procedure in many preclinical and clinical laboratories. This overview highlights a number of issues involving "small molecule drugs", bioanalytical liquid chromatography-tandem mass spectrometry, which are frequently encountered during assay development. In addition, possible solutions to these issues are proposed with examples in some of the case studies. Topics such as chromatographic peak shape, carry-over, cross-talk, standard curve non-linearity, internal standard selection, matrix effect, and metabolite interference are presented. Since plasma is one of the most widely adopted biological fluid in drug discovery and development, the focus of this discussion will be limited to plasma analysis. This article is not intended to be a comprehensive overview and readers are encouraged to refer to the citations herein.

  17. Single-step preparation of selected biological fluids for the high performance liquid chromatographic analysis of fat-soluble vitamins and antioxidants.

    Science.gov (United States)

    Lazzarino, Giacomo; Longo, Salvatore; Amorini, Angela Maria; Di Pietro, Valentina; D'Urso, Serafina; Lazzarino, Giuseppe; Belli, Antonio; Tavazzi, Barbara

    2017-12-08

    Fat-soluble vitamins and antioxidants are of relevance in health and disease. Current methods to extract these compounds from biological fluids mainly need use of multi-steps and multi organic solvents. They are time-consuming and difficult to apply to treat simultaneously large sample number. We here describe a single-step, one solvent extraction of fat-soluble vitamins and antioxidants from biological fluids, and the chromatographic separation of all-trans-retinoic acid, 25-hydroxycholecalciferol, all-trans-retinol, astaxanthin, lutein, zeaxanthin, trans-β-apo-8'-carotenal, γ-tocopherol, β-cryptoxanthin, α-tocopherol, phylloquinone, lycopene, α-carotene, β-carotene and coenzyme Q 10 . Extraction is obtained by adding one volume of biological fluid to two acetonitrile volumes, vortexing for 60s and incubating for 60min at 37°C under agitation. HPLC separation occurs in 30min using Hypersil C18, 100×4.6mm, 5μm particle size column, gradient from 70% methanol+30% H 2 O to 100% acetonitrile, flow rate of 1.0ml/min and 37°C column temperature. Compounds are revealed using highly sensitive UV-VIS diode array detector. The HPLC method suitability was assessed in terms of sensitivity, reproducibility and recovery. Using the present extraction and chromatographic conditions we obtained values of the fat-soluble vitamins and antioxidants in serum from 50 healthy controls similar to those found in literature. Additionally, the profile of these compounds was also measured in seminal plasma from 20 healthy fertile donors. Results indicate that this simple, rapid and low cost sample processing is suitable to extract fat-soluble vitamins and antioxidants from biological fluids and can be applied in clinical and nutritional studies. Copyright © 2017 Elsevier B.V. All rights reserved.

  18. Restricted access magnetic materials prepared by dual surface modification for selective extraction of therapeutic drugs from biological fluids

    Energy Technology Data Exchange (ETDEWEB)

    Wang Yu; Wang Yuxia; Chen Lei [School of Pharmaceutical Science and Technology, Tianjin University, Tianjin 300072 (China); Wan Qianhong, E-mail: qhwan@tju.edu.cn [School of Pharmaceutical Science and Technology, Tianjin University, Tianjin 300072 (China)

    2012-02-15

    Magnetic porous particles with dual functionality have been prepared by a two-step procedure and evaluated as novel restricted access materials for extraction of therapeutic agents from biological fluids. The magnetic silica particles served as scaffolds were first modified with diol groups, which were then converted to octadecyl esters through reaction with stearoyl chloride. In the second step, the octadecyl esters on the exterior surface were hydrolyzed by the action of lipase to yield magnetic particles with hydrophobic reversed-phase ligands on the inner surface and biocompatible diol groups on the outer surface. The restricted access behavior of the resulting materials was confirmed by differential binding of small molecules such as methotrexate (MTX), leucovorin (LV) and folic acid (FA) relative to bovine serum albumin. While MTX, LV and FA were all bound to the magnetic particles with high affinity, the adsorption of the protein was markedly reduced due to size exclusion effect. The utility of the magnetic particles for sample preparation was tested in solid-phase extraction of MTX, LV and FA from spiked human serum and the effects of the SPE conditions on the recovery of the analytes were systematically studied. Moreover, the magnetic particle-based sample preparation procedure coupled with reversed-phase liquid chromatography analysis was validated in terms of specificity, linearity and reproducibility. The method was shown to be free from interference of endogenous compounds and linear over the concentration range of 0.5-10 {mu}g/mL for the three drugs studied. The limits of detection for the three drugs in serum were in the range of 0.160-0.302 {mu}g/mL. Reproducibility expressed as the RSD of the recovery for ten replicated extractions at three different concentrations was found to be less than 8.93%. With a unique combination of surface functionality with magnetic cores, the restricted access magnetic particles may be adapted in automated and high

  19. Restricted access magnetic materials prepared by dual surface modification for selective extraction of therapeutic drugs from biological fluids

    Science.gov (United States)

    Wang, Yu; Wang, Yuxia; Chen, Lei; Wan, Qian-Hong

    2012-02-01

    Magnetic porous particles with dual functionality have been prepared by a two-step procedure and evaluated as novel restricted access materials for extraction of therapeutic agents from biological fluids. The magnetic silica particles served as scaffolds were first modified with diol groups, which were then converted to octadecyl esters through reaction with stearoyl chloride. In the second step, the octadecyl esters on the exterior surface were hydrolyzed by the action of lipase to yield magnetic particles with hydrophobic reversed-phase ligands on the inner surface and biocompatible diol groups on the outer surface. The restricted access behavior of the resulting materials was confirmed by differential binding of small molecules such as methotrexate (MTX), leucovorin (LV) and folic acid (FA) relative to bovine serum albumin. While MTX, LV and FA were all bound to the magnetic particles with high affinity, the adsorption of the protein was markedly reduced due to size exclusion effect. The utility of the magnetic particles for sample preparation was tested in solid-phase extraction of MTX, LV and FA from spiked human serum and the effects of the SPE conditions on the recovery of the analytes were systematically studied. Moreover, the magnetic particle-based sample preparation procedure coupled with reversed-phase liquid chromatography analysis was validated in terms of specificity, linearity and reproducibility. The method was shown to be free from interference of endogenous compounds and linear over the concentration range of 0.5-10 μg/mL for the three drugs studied. The limits of detection for the three drugs in serum were in the range of 0.160-0.302 μg/mL. Reproducibility expressed as the RSD of the recovery for ten replicated extractions at three different concentrations was found to be less than 8.93%. With a unique combination of surface functionality with magnetic cores, the restricted access magnetic particles may be adapted in automated and high

  20. Restricted access magnetic materials prepared by dual surface modification for selective extraction of therapeutic drugs from biological fluids

    International Nuclear Information System (INIS)

    Wang Yu; Wang Yuxia; Chen Lei; Wan Qianhong

    2012-01-01

    Magnetic porous particles with dual functionality have been prepared by a two-step procedure and evaluated as novel restricted access materials for extraction of therapeutic agents from biological fluids. The magnetic silica particles served as scaffolds were first modified with diol groups, which were then converted to octadecyl esters through reaction with stearoyl chloride. In the second step, the octadecyl esters on the exterior surface were hydrolyzed by the action of lipase to yield magnetic particles with hydrophobic reversed-phase ligands on the inner surface and biocompatible diol groups on the outer surface. The restricted access behavior of the resulting materials was confirmed by differential binding of small molecules such as methotrexate (MTX), leucovorin (LV) and folic acid (FA) relative to bovine serum albumin. While MTX, LV and FA were all bound to the magnetic particles with high affinity, the adsorption of the protein was markedly reduced due to size exclusion effect. The utility of the magnetic particles for sample preparation was tested in solid-phase extraction of MTX, LV and FA from spiked human serum and the effects of the SPE conditions on the recovery of the analytes were systematically studied. Moreover, the magnetic particle-based sample preparation procedure coupled with reversed-phase liquid chromatography analysis was validated in terms of specificity, linearity and reproducibility. The method was shown to be free from interference of endogenous compounds and linear over the concentration range of 0.5-10 μg/mL for the three drugs studied. The limits of detection for the three drugs in serum were in the range of 0.160-0.302 μg/mL. Reproducibility expressed as the RSD of the recovery for ten replicated extractions at three different concentrations was found to be less than 8.93%. With a unique combination of surface functionality with magnetic cores, the restricted access magnetic particles may be adapted in automated and high

  1. Multiwall carbon nanotubes chemically modified carbon paste electrodes for determination of gentamicin sulfate in pharmaceutical preparations and biological fluids.

    Science.gov (United States)

    Khalil, M M; Abed El-Aziz, G M

    2016-02-01

    This article focused on the construction and characteristics of novel and sensitive gentamicin carbon paste electrodes which are based on the incorporation of multiwall carbon nanotubes (MWCNTs) which improve the characteristics of the electrodes. The electrodes were constructed based on gentamicin-phosphotungstate (GNS-PTA) called CPE1, gentamicin-phosphomolybdate (GNS-PMA) called CPE2, GNS-PTA+ MWMCNTs called MWCPE1, and GNS-PMA+ MWMCNTs called MWCPE2. The constructed electrodes, at optimum paste composition, exhibited good Nernstian response for determination of gentamicin sulfate (GNS) over a linear concentration range from 2.5×10(-6) to 1×10(-2), 3.0×10(-6) to 1×10(-2), 4.9×10(-7) to 1×10(-2) and 5.0×10(-7) to 1×10(-2)molL(-1), with lower detection limit 1×10(-6), 1×10(-6), 1.9×10(-7) and 2.2×10(-7)molL(-1), and with slope values of 29.0±0.4, 29.2±0.7, 31.2±0.5 and 31.0±0.6mV/decade for CPE1, CPE2, MWCPE1 and MWCPE2, respectively. The response of electrodes is not affected by pH in the range 3-8 for CPE1 and CPE2 and in the range 2.5-8.5 for MWCPE1 and MWCPE2. The results showed fast dynamic response time (about 8-5s) and long lifetime (more than 2months) for all electrodes. The sensors showed high selectivity for gentamicin sulfate (GNS) with respect to a large number of interfering species. The constructed electrodes were successfully applied for determination of GNS in pure form, its pharmaceutical preparations and biological fluids using standard addition and potentiometric titration methods with high accuracy and precision. Published by Elsevier B.V.

  2. Biology

    Indian Academy of Sciences (India)

    I am particularly happy that the Academy is bringing out this document by Professor M S. Valiathan on Ayurvedic Biology. It is an effort to place before the scientific community, especially that of India, the unique scientific opportunities that arise out of viewing Ayurveda from the perspective of contemporary science, its tools ...

  3. Elimination and Concentration Correlations between Edible Tissues and Biological Fluids and Hair of Ractopamine in Pigs and Goats Fed with Ractopamine-Medicated Feed.

    Science.gov (United States)

    Huang, Lingli; Shi, Jingfei; Pan, Yuanhu; Wang, Liye; Chen, Dongmei; Xie, Shuyu; Liu, Zhenli; Yuan, Zonghui

    2016-03-09

    Ractopamine (RAC), a β-adrenergic leanness-enhancing agent, endangers the food safety of animal products because of overdosing and illegal use in food animals. Excretion and residue depletion of RAC in pigs and goats were investigated to determine a representative biological fluid or surface tissue for preslaughter monitoring. After a single oral gavage of RAC, 64-67% of the dose was excreted from the urine of pigs and goats within 12-24 h. RAC persisted the longest in the hair of pigs and goats but depleted rapidly in the plasma, muscle, and fat. Urine and hair were excellent for predicting RAC residues in edible tissues of pigs, whereas plasma and urine were satisfactory body fluids for the prediction of RAC concentrations in edible tissues of goats. These data provided a simple and economical preslaughter living monitoring method for the illegal use and violative residue of RAC in food animals.

  4. Viscous flow through slowly expanding or contracting porous walls with low seepage Reynolds number: a model for transport of biological fluids through vessels.

    Science.gov (United States)

    Dinarvand, Saeed

    2011-10-01

    In this article, the problem of laminar, isothermal, incompressible and viscous flow in a rectangular domain bounded by two moving porous walls, which enable the fluid to enter or exit during successive expansions or contractions, is investigated. The governing non-linear equations and their associated boundary conditions are transformed into a highly non-linear ordinary differential equation. The series solution of the problem is obtained by utilising the homotopy perturbation method. Graphical results are presented to investigate the influence of the non-dimensional wall dilation rate and seepage Reynolds number (Re) on the velocity, normal pressure distribution and wall shear stress. Since the transport of biological fluids through contracting or expanding vessels is characterised by low seepage Res, the current study focuses on the viscous flow driven by small wall contractions and expansions of two weakly permeable walls.

  5. Multiwall carbon nanotubes chemically modified carbon paste electrodes for determination of gentamicin sulfate in pharmaceutical preparations and biological fluids

    Energy Technology Data Exchange (ETDEWEB)

    Khalil, M.M., E-mail: magdy_mmagdy@yahoo.com; Abed El-aziz, G.M., E-mail: Gamal_abedelaziz@yahoo.com

    2016-02-01

    This article focused on the construction and characteristics of novel and sensitive gentamicin carbon paste electrodes which are based on the incorporation of multiwall carbon nanotubes (MWCNTs) which improve the characteristics of the electrodes. The electrodes were constructed based on gentamicin-phosphotungstate (GNS-PTA) called CPE{sub 1}, gentamicin-phosphomolybdate (GNS-PMA) called CPE{sub 2}, GNS-PTA + MWMCNTs called MWCPE{sub 1}, and GNS-PMA + MWMCNTs called MWCPE{sub 2}. The constructed electrodes, at optimum paste composition, exhibited good Nernstian response for determination of gentamicin sulfate (GNS) over a linear concentration range from 2.5 × 10{sup −6} to 1 × 10{sup −2}, 3.0 × 10{sup −6} to 1 × 10{sup −2}, 4.9 × 10{sup −7} to 1 × 10{sup −2} and 5.0 × 10{sup −7} to 1 × 10{sup −2} mol L{sup −1}, with lower detection limit 1 × 10{sup −6}, 1 × 10{sup −6}, 1.9 × 10{sup −7} and 2.2 × 10{sup −7} mol L{sup −1}, and with slope values of 29.0 ± 0.4, 29.2 ± 0.7, 31.2 ± 0.5 and 31.0 ± 0.6 mV/decade for CPE{sub 1}, CPE{sub 2}, MWCPE{sub 1} and MWCPE{sub 2}, respectively. The response of electrodes is not affected by pH in the range 3–8 for CPE{sub 1} and CPE{sub 2} and in the range 2.5–8.5 for MWCPE{sub 1} and MWCPE{sub 2}. The results showed fast dynamic response time (about 8–5 s) and long lifetime (more than 2 months) for all electrodes. The sensors showed high selectivity for gentamicin sulfate (GNS) with respect to a large number of interfering species. The constructed electrodes were successfully applied for determination of GNS in pure form, its pharmaceutical preparations and biological fluids using standard addition and potentiometric titration methods with high accuracy and precision. - Graphical abstract: The incorporation of MWCNTs in paste composition improves the characteristics of the MWCPE electrodes which show better responses in terms of sensitivity, Nernstian slope, linear range, faster

  6. Analysis of Cell Biomechanics Response to Gravity:A Fluids for Biology Study Utilizing NASA Glenns Zero Gravity Research Facility

    Science.gov (United States)

    Bomani, Bilal M. M.; Kassemi, Mohammad; Neumann, Eric S.

    2016-01-01

    It remains unclear how biological cells sense and respond to gravitational forces. Leading scientists state that a large gap exists in the understanding of physiological and molecular adaptation that occurs as biology enters the spaceflight realm. We are seeking a method to fully understand how cells sense microgravity/gravity and what triggers their response.

  7. High-throughput analysis of drugs in biological fluids by desorption electrospray ionization mass spectrometry coupled with thin liquid membrane extraction

    DEFF Research Database (Denmark)

    Rosting, Cecilie; Pedersen-Bjergaard, Stig; Hansen, Steen Honore'

    2013-01-01

    Biological fluids such as urine, saliva and whole blood were analyzed for contents of drugs by a new combination of desorption electrospray ionization mass spectrometry (DESI-MS) and thin liquid membrane extraction (TLME). Analytes from the sample were extracted into a thin liquid membrane...... into the method, methadone was detected in urine in full-scan mode with an LOD of 4 ng mL(-1), while amitriptyline, nortriptyline and pethidine showed LODs of 17 ng mL(-1). Quantification was possible for several basic drugs using one common internal standard, providing relative accuracies in the range of 10...

  8. Affinity purification of native glycodelin from amniotic fluid for biological investigations and development of a glycodelin ELISA for clinical studies

    DEFF Research Database (Denmark)

    Sørensen, Steen; Myrhøj, Vibeke; Nguyen, Thanh Ha

    2017-01-01

    for functional studies because the carbohydrate part can be lacking or be insufficient in recombinant glycodelin from prokaryotic and eukaryotic cell systems. METHODS AND RESULTS: Native glycodelin was purified from amniotic fluid by a series of affinity chromatography steps and had many glycosylated forms...

  9. The detection and quantitative analysis of the psychoactive component of Salvia divinorum, salvinorin A, in human biological fluids using liquid chromatography-mass spectrometry.

    Science.gov (United States)

    McDonough, Pamela C; Holler, Justin M; Vorce, Shawn P; Bosy, Thomas Z; Magluilo, Joseph; Past, Marilyn R

    2008-01-01

    Salvia divinorum, a member of the mint plant family, has hallucinogenic properties that have become increasingly sought after by recreational drug users. The main psychoactive component, salvinorin A, has potency comparable to lysergic acid diethylamide. Though still legal to possess in most of the United States and much of Europe, little is known regarding the compound's long-term health effects, addiction liability, and pharmacokinetics. Limited data are available in the scientific literature, and few analytical methods are published for the detection in human biological fluids. These factors contribute to the unfamiliarity of the compound and complicate the method development process necessary to accommodate special requested testing for salvinorin A. A sensitive analytical method for the detection and quantitation of salvinorin A in human biological fluids was developed and validated to resolve analytical shortcomings. The method utilizes a solid-phase extraction technique coupled with liquid chromatography-electrospray ionization mass spectrometry operated in selected ion monitoring mode. The assay has a linear range of 5.0-100 ng/mL with a correlation coefficient of 0.997. The limit of detection and limit of quantitation were experimentally determined as 2.5 and 5.0 ng/mL, respectively. The method has been applied to blood and urine samples successfully and can be used to detect the presence of salvinorin A in forensic testing.

  10. Integration of biological kinetics and computational fluid dynamics to model the growth of Nannochloropsis salina in an open channel raceway.

    Science.gov (United States)

    Park, Stephen; Li, Yebo

    2015-05-01

    Microalgal growth and systemic productivity is not only affected by environmental conditions such as temperature, irradiance, and nutrient concentrations, but also by physical processes such as fluid flow and particulate sedimentation. Modeling and simulating the system is a cost-effective way to predict the growth behavior under various environmental and physical conditions while determining effective engineering approaches to maximize productivity. Many mathematical models have been proposed to describe microalgal growth, while computational fluid dynamics (CFD) have been used to model the behavior of many fluid systems. Integrating the growth kinetics into a CFD model can help researchers understand the impact of a variety of parameters and determine what measures can be taken to overcome some obstacles in the aquaculture industry--self-shading, biomass sedimentation, and contamination--which prevent the production of high biomass yields. The aim of this study was to integrate physical and environmental effects to predict space- and time-dependent algal growth in industrial scale raceways. A commercial CFD software, ANSYS-Fluent 14.5, was used to solve the proposed models in regards to fluid flow, heat transfer, and nutrient balance. User-defined functions written in C language were used to incorporate the kinetic equations into a three-dimensional standard k-ε turbulence model of an open channel raceway system driven by a single paddlewheel. Simulated results were compared with light intensity, temperature, nutrient concentration, and algal biomass data acquired for 56 day from an industrial scale raceway pond constructed for the growth of Nannochloropsis salina and were observed to be in good agreement with one another. There was up to a 17.6% increase in simulated productivity when the incoming CO2 concentration was increased from 0.0006 to 0.150 g L(-1), while the effect of paddlewheel velocity was not significant. Sensitivity analysis showed that the model

  11. Detection of cancerous biological tissue areas by means of infrared absorption and SERS spectroscopy of intercellular fluid

    Science.gov (United States)

    Velicka, M.; Urboniene, V.; Ceponkus, J.; Pucetaite, M.; Jankevicius, F.; Sablinskas, V.

    2015-08-01

    We present a novel approach to the detection of cancerous kidney tissue areas by measuring vibrational spectra (IR absorption or SERS) of intercellular fluid taken from the tissue. The method is based on spectral analysis of cancerous and normal tissue areas in order to find specific spectral markers. The samples were prepared by sliding the kidney tissue over a substrate - surface of diamond ATR crystal in case of IR absorption or calcium fluoride optical window in case of SERS. For producing the SERS signal the dried fluid film was covered by silver nanoparticle colloidal solution. In order to suppress fluorescence background the measurements were performed in the NIR spectral region with the excitation wavelength of 1064 nm. The most significant spectral differences - spectral markers - were found in the region between 400 and 1800 cm-1, where spectral bands related to various vibrations of fatty acids, glycolipids and carbohydrates are located. Spectral markers in the IR and SERS spectra are different and the methods can complement each other. Both of them have potential to be used directly during surgery. Additionally, IR absorption spectroscopy in ATR mode can be combined with waveguide probe what makes this method usable in vivo.

  12. Analysis of Investigational Drugs in Biological Fluids- Method Development and Analysis of Pre-Clinical and Clinical Samples.

    Science.gov (United States)

    1999-09-01

    to reach equilibrium with erythrocytes. Sample Preparation Procedures Suitable preparation of the biological specimens is essential for the...antibiotics that are zwitterionic in nature, generally possess very low water-to- oil partition coefficients and, thus, are extremely difficult to...antileishmanial drug in hamsters infected with Leishmania donovani .9 Because antimony compounds are not always effective and the other drugs in use have

  13. Flow-injection chemiluminescence determination of enalapril maleate in pharmaceuticals and biological fluids using tris(2,2'-bipyridyl)ruthenium(II).

    Science.gov (United States)

    Alarfaj, Nawal A A

    2003-08-01

    A chemiluminescence (CL) method using flow injection (FI) has been investigated for the rapid and sensitive determination of enalapril maleate. The method is based on the CL reaction of the drug with tris(2,2'-bipyridyl)ruthenium(II), Ru(bipy)3(2+) and acidic potassium permanganate. After selecting the best operating parameters, calibration graphs were obtained over concentration ranges of 0.005-0.2 microg/ml and 0.7-100 microg/ml with a detection limit (S/N=2) of 1.0 ng/ml. The average % found was 99.9 +/- 0.7 and 100.2 +/- 0.3 for the two concentration ranges respectively. %RSD (n=10) for 5.0 microg/ml was 0.44. The method was successfully applied to the determination of enalapril maleate in dosage forms and biological fluids without interferences.

  14. Ultra-sensitive electrochemical sensing of acetaminophen and codeine in biological fluids using CuO/CuFe2O4nanoparticles as a novel electrocatalyst.

    Science.gov (United States)

    Hasanpour, Foroozan; Taei, Masoumeh; Tahmasebi, Somayeh

    2018-04-01

    Copper ferrite-copper oxide (CuO-CuFe 2 O 4 ) nanoparticles as a semiconductor composite with p-n junction were synthesized by co-precipitation reaction. Then, a novel CuO-CuFe 2 O 4 carbon paste modified electrode was fabricated which displays an effectual electrocatalytic response to the oxidation of acetaminophen (AC) and codeine (CO). A linear range of 0.01-1.5 μmol L -1 and 0.06-10.0 μmol L -1 with the detection limits of 0.007 μmol L -1 and 0.01 μmol L -1 were achieved for AC and CO, respectively. The practical usage of the proposed sensor revealed reasonable results for quantification of AC and CO in biological fluids. Copyright © 2017. Published by Elsevier B.V.

  15. Ultra-sensitive electrochemical sensing of acetaminophen and codeine in biological fluids using CuO/CuFe2O4 nanoparticles as a novel electrocatalyst

    Directory of Open Access Journals (Sweden)

    Foroozan Hasanpour

    2018-04-01

    Full Text Available Copper ferrite−copper oxide (CuO-CuFe2O4 nanoparticles as a semiconductor composite with p–n junction were synthesized by co-precipitation reaction. Then, a novel CuO-CuFe2O4 carbon paste modified electrode was fabricated which displays an effectual electrocatalytic response to the oxidation of acetaminophen (AC and codeine (CO. A linear range of 0.01–1.5 μmol L−1 and 0.06–10.0 μmol L−1 with the detection limits of 0.007 μmol L−1 and 0.01 μmol L−1 were achieved for AC and CO, respectively. The practical usage of the proposed sensor revealed reasonable results for quantification of AC and CO in biological fluids. Keywords: Acetaminophen, Codeine, Copper ferrite/copper oxide nanoparticles, Electrochemical sensing

  16. Identification of xenobiotic metabolites from biological fluids using flow injection analysis high-resolution mass spectrometry and post-acquisition data filtering.

    Science.gov (United States)

    Rathahao-Paris, Estelle; Paris, Alain; Bursztyka, Julian; Jaeg, Jean-Philippe; Cravedi, Jean-Pierre; Debrauwer, Laurent

    2014-12-30

    Concern for public health entails the need to evaluate the degree of exposure of population to toxicants. To do this, robust high-throughput approaches are required to be able to perform a large number of analyses in cohort studies. In this study, a data-filtering procedure was applied to mass spectral data acquired by direct analysis of biological fluids leading to rapid detection of metabolites in a model xenobiotic system. Flow injection analysis (FIA) coupled to negative electrospray ionization (ESI)-LTQ Orbitrap Fourier transform mass spectrometry was used to directly analyze urine of rats treated with vinclozolin. Tandem mass spectrometry (MS/MS) experiments were subsequently performed for confirmation of a new metabolite structure. The isotope filtering based on the difference between accurate masses of (35)Cl and (37)Cl was applied to the raw data for the specific detection of ions containing at least one chlorine atom. Seven metabolites of vinclozolin were manually identified thanks to the characteristic isotope pattern of dichlorinated compounds. A new metabolite of vinclozolin was detected for the first time and identified as a sulfate conjugate. The application of an isotope-filtering procedure allowed the selective extraction of pertinent signals from the data. The processed mass spectrum was greatly simplified, significantly facilitating the detection of the seven metabolites previously identified. The use of FIA-HRMS in combination with dedicated bio-informatics data processing is shown to be an efficient approach for the rapid detection of metabolites in biological fluids. This is a very promising high-throughput approach for rapid characterization of the exposure status to xenobiotics. Copyright © 2014 John Wiley & Sons, Ltd.

  17. A high-throughput method for the simultaneous determination of multiple mycotoxins in human and laboratory animal biological fluids and tissues by PLE and HPLC-MS/MS.

    Science.gov (United States)

    Cao, Xiaoqin; Wu, Shuangchan; Yue, Yuan; Wang, Shi; Wang, Yuting; Tao, Li; Tian, Hui; Xie, Jianmei; Ding, Hong

    2013-12-30

    A high-throughput method for the determination of 28 mycotoxins involving pressurised liquid extraction (PLE) coupled with liquid chromatography-tandem mass spectrometry (HPLC-MS/MS) has been optimised and validated for determination in various biological fluids and tissues of human and laboratory animals. High-throughput analysis was achieved using PLE pre-treatment and without the need for any cleanup. The extraction solvent was acetonitrile/water/acetic acid (80/19/1, v/v/v). The static extraction time was 5min. The extraction pressure and temperature were 1500psi and 140°C, respectively. The flush volume was 60%. The limits of detection, which were defined as CCα, varied from 0.01μg/kg (μg/L) to 0.69μg/kg (μg/L). The recoveries of spiked samples from 0.20μg/kg (μg/L) to 2μg/kg (μg/L) ranged from 71% to 100.5% with relative standard deviations of less than 17.5%, except FB1 and FB2 recoveries, which were lower than 60%. The method was successfully applied in real samples, and the data indicate that this technique is a useful analytical method for the determination of mycotoxins from humans and animals. To the best of our knowledge, this method is the first for the large-scale testing of multi-class mycotoxins in all types of biological fluids and tissues that uses PLE and HPLC-MS/MS. Copyright © 2013 Elsevier B.V. All rights reserved.

  18. Cerebrospinal fluid and blood biomarkers for neurodegenerative dementias: An update of the Consensus of the Task Force on Biological Markers in Psychiatry of the World Federation of Societies of Biological Psychiatry.

    Science.gov (United States)

    Lewczuk, Piotr; Riederer, Peter; O'Bryant, Sid E; Verbeek, Marcel M; Dubois, Bruno; Visser, Pieter Jelle; Jellinger, Kurt A; Engelborghs, Sebastiaan; Ramirez, Alfredo; Parnetti, Lucilla; Jack, Clifford R; Teunissen, Charlotte E; Hampel, Harald; Lleó, Alberto; Jessen, Frank; Glodzik, Lidia; de Leon, Mony J; Fagan, Anne M; Molinuevo, José Luis; Jansen, Willemijn J; Winblad, Bengt; Shaw, Leslie M; Andreasson, Ulf; Otto, Markus; Mollenhauer, Brit; Wiltfang, Jens; Turner, Martin R; Zerr, Inga; Handels, Ron; Thompson, Alexander G; Johansson, Gunilla; Ermann, Natalia; Trojanowski, John Q; Karaca, Ilker; Wagner, Holger; Oeckl, Patrick; van Waalwijk van Doorn, Linda; Bjerke, Maria; Kapogiannis, Dimitrios; Kuiperij, H Bea; Farotti, Lucia; Li, Yi; Gordon, Brian A; Epelbaum, Stéphane; Vos, Stephanie J B; Klijn, Catharina J M; Van Nostrand, William E; Minguillon, Carolina; Schmitz, Matthias; Gallo, Carla; Lopez Mato, Andrea; Thibaut, Florence; Lista, Simone; Alcolea, Daniel; Zetterberg, Henrik; Blennow, Kaj; Kornhuber, Johannes

    2017-10-27

    In the 12 years since the publication of the first Consensus Paper of the WFSBP on biomarkers of neurodegenerative dementias, enormous advancement has taken place in the field, and the Task Force takes now the opportunity to extend and update the original paper. New concepts of Alzheimer's disease (AD) and the conceptual interactions between AD and dementia due to AD were developed, resulting in two sets for diagnostic/research criteria. Procedures for pre-analytical sample handling, biobanking, analyses and post-analytical interpretation of the results were intensively studied and optimised. A global quality control project was introduced to evaluate and monitor the inter-centre variability in measurements with the goal of harmonisation of results. Contexts of use and how to approach candidate biomarkers in biological specimens other than cerebrospinal fluid (CSF), e.g. blood, were precisely defined. Important development was achieved in neuroimaging techniques, including studies comparing amyloid-β positron emission tomography results to fluid-based modalities. Similarly, development in research laboratory technologies, such as ultra-sensitive methods, raises our hopes to further improve analytical and diagnostic accuracy of classic and novel candidate biomarkers. Synergistically, advancement in clinical trials of anti-dementia therapies energises and motivates the efforts to find and optimise the most reliable early diagnostic modalities. Finally, the first studies were published addressing the potential of cost-effectiveness of the biomarkers-based diagnosis of neurodegenerative disorders.

  19. Dual-Mode Optical Sensing of Histamine at Nanomolar Concentrations in Complex Biological Fluids and Living Cells.

    Science.gov (United States)

    Dey, Nilanjan; Ali, Asfa; Podder, Santosh; Majumdar, Shamik; Nandi, Dipankar; Bhattacharya, Santanu

    2017-09-04

    An easily synthesized fluorescein-based luminescent dye has been utilized for the dual-mode detection of histamine at nanomolar concentrations at pH 7.0 in water. The specific response to histamine was achieved by imidazole-catalyzed 'imine formation' reaction. The protocol was subsequently applied for the estimation of histamine in complex biological milieu such as human blood serum and urine samples. Furthermore, the dose-dependent cellular uptake of histamine and de novo synthesis (by thapsigargin treatment) was visualized in RAW 264.7, a mouse macrophage cell line. We have also developed portable paper strips for rapid, on-site detection of histamine without involving costly instruments. © 2017 Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim.

  20. Development of on-line spectrofluorimetric methodology for selenium monitoring in foods and biological fluids using Chrome azurol S quenching.

    Science.gov (United States)

    Santarossa, Débora G; Fernández, Liliana P

    2017-09-01

    A novel, simple and accurate on-line green methodology for Se(IV) monitoring by molecular fluorescence has been developed. Because the analyte does not exhibit fluorescence, the organic dye Chrome azurol S (CAS) has been chosen to allow detection. The effect of metal-quenching on CAS excitation and emission conditions (λex=300nm; λem=407nm) was used as criterion for analyte quantification in presence of sodium cholate bile salt (NaC). The quenching mechanism was explored, and it can be classified as a collisional type with a Stern-Volmer constant value of 3.0×10 7 molL -1 . To improve the sampling rate, minimize the reagent consumption and generated wastes, an on-line configuration was designed. Experimental variables that affect the fluorimetric sensitivity were optimized using uni-variation assays. Under optimal experimental conditions, the limit of detection was 0.27µgL -1 with a lineal range for Se(IV) concentration from 0.84 to 6.00µgL -1 . The developed methodology is low cost and fast sampling, allowing Se(IV) quantification in the presence of other common ions. Bulbous vegetables and biological samples were successfully analyzed with an average recovery close to 100%. Copyright © 2017 Elsevier B.V. All rights reserved.

  1. Dynamics Analysis of Fluid-Structure Interaction for a Biologically-Inspired Biped Robot Running on Water

    Directory of Open Access Journals (Sweden)

    Linsen Xu

    2013-10-01

    Full Text Available A kinematics analysis of a biologically-inspired biped robot is carried out, and the trajectory of the robot foot is understood. For calculating the pressure distribution across a robot foot before touching the surface of water, the compression flow of air and the depression motion of the water surface are considered. The pressure model after touching the water surface has been built according to the theory of rigid body planar motion. The multi-material ALE algorithm is applied to emulate the course of the foot slapping water. The simulation results indicate that the model of the bionic robot can satisfy the water-running function. The real prototype of the robot is manufactured to test its function of running on water. When the biped robot is running on water, the average force generated by the propulsion mechanism is about 1.3N. The experimental results show that the propulsion system can satisfy the requirement of biped robot running on water.

  2. Computational Fluid Dynamic Simulations of Maternal Circulation: Wall Shear Stress in the Human Placenta and Its Biological Implications.

    Directory of Open Access Journals (Sweden)

    E Lecarpentier

    Full Text Available In the human placenta the maternal blood circulates in the intervillous space (IVS. The syncytiotrophoblast (STB is in direct contact with maternal blood. The wall shear stress (WSS exerted by the maternal blood flow on the STB has not been evaluated. Our objective was to determine the physiological WSS exerted on the surface of the STB during the third trimester of pregnancy.To gain insight into the shear stress levels that the STB is expected to experience in vivo, we have formulated three different computational models of varying levels of complexity that reflect different physical representations of the IVS. Computations of the flow fields in all models were performed using the CFD module of the finite element code COMSOL Multiphysics 4.4. The mean velocity of maternal blood in the IVS during the third trimester was measured in vivo with dynamic MRI (0.94±0.14 mm.s-1. To investigate if the in silico results are consistent with physiological observations, we studied the cytoadhesion of human parasitized (Plasmodium falciparum erythrocytes to primary human STB cultures, in flow conditions with different WSS values.The WSS applied to the STB is highly heterogeneous in the IVS. The estimated average values are relatively low (0.5±0.2 to 2.3±1.1 dyn.cm-2. The increase of WSS from 0.15 to 5 dyn.cm-2 was associated with a significant decrease of infected erythrocyte cytoadhesion. No cytoadhesion of infected erythrocytes was observed above 5 dyn.cm-2 applied for one hour.Our study provides for the first time a WSS estimation in the maternal placental circulation. In spite of high maternal blood flow rates, the average WSS applied at the surface of the chorionic villi is low (<5 dyn.cm-2. These results provide the basis for future physiologically-relevant in vitro studies of the biological effects of WSS on the STB.

  3. Biological artificial fluid-induced non-lamellar phases in glyceryl monooleate: the kinetics pathway and its digestive process by bile salts.

    Science.gov (United States)

    Zhou, Yanyan; Wang, Qifang; Wang, Yan; Xu, Hui; Yuan, Bo; Li, Sanming; Liu, Hongzhuo

    2014-02-01

    The cubic (Q(II)) phase is a promising sustained-release system. However, its rigid gel-like propensity is highly viscous, which makes it difficult to handle in pharmaceutical applications. To circumvent this problem, a less viscous lamellar (L(α)) phase that could spontaneously transform to Q(II) phase by the introduction of water or biological artificial fluid can be used. However, the kinetics pathway of phase transition, susceptibility to digestive processes and impact of the transition on drug release are not yet well understood. We investigated various biological artificial fluid-induced L(α) to inverse Q(II) phase transition over time in glyceryl monooleate (GMO) by water penetration scan and light polarizing microscopy. To reveal the structure stability, fluorescence spectroscopy studies were conducted using pyrene as a probe. Furthermore, the release mechanism of pyrene as a lipophilic drug model in the spontaneously formed Q(II) was investigated. Although hexagonal (H(II)) mesophases occurred when phosphate buffered saline (PBS) 7.4, 0.1 M HCl or sodium taurocholate (NaTC) solutions were introduced to GMO at room temperature, they disappear with the exception of 0.1 M HCl at 37 °C. Compared with 25 °C, L(α) to Q(II) phase transition was in a faster rate as almost completely transforms were observed after 2 h post-immersion. The spontaneously formed mesophases were stable over 24 h immersions in PBS or pancreatic lipase solutions as proven by the extremely low fluorescence signal, however they were digestible by bile salts. This result indicated that digestion by bile salts was the major pathway instead of digestion by lipases. Moreover, pyrene fluorescence spectroscopy confirmed that the digestion by bile salts induced the formation of GMO-bile salt mixed micelles whose performance depended on the bile salt concentrations. This dependence influenced the drug release from the spontaneously formed Q(II) phase. All the results concluded that

  4. Magnetic micro-solid-phase extraction based on magnetite-MCM-41 with gas chromatography-mass spectrometry for the determination of antidepressant drugs in biological fluids.

    Science.gov (United States)

    Kamaruzaman, Sazlinda; Sanagi, Mohd Marsin; Yahaya, Noorfatimah; Wan Ibrahim, Wan Aini; Endud, Salasiah; Wan Ibrahim, Wan Nazihah

    2017-11-01

    A new facile magnetic micro-solid-phase extraction coupled to gas chromatography and mass spectrometry detection was developed for the extraction and determination of selected antidepressant drugs in biological fluids using magnetite-MCM-41 as adsorbent. The synthesized sorbent was characterized by several spectroscopic techniques. The maximum extraction efficiency for extraction of 500 μg/L antidepressant drugs from aqueous solution was obtained with 15 mg of magnetite-MCM-41 at pH 12. The analyte was desorbed using 100 μL of acetonitrile prior to gas chromatography determination. This method was rapid in which the adsorption procedure was completed in 60 s. Under the optimized conditions using 15 mL of antidepressant drugs sample, the calibration curve showed good linearity in the range of 0.05-500 μg/L (r 2  = 0.996-0.999). Good limits of detection (0.008-0.010 μg/L) were obtained for the analytes with good relative standard deviations of drugs. This method was successfully applied to the determination of amitriptyline and chlorpromazine in plasma and urine samples. The recoveries of spiked plasma and urine samples were in the range of 86.1-115.4%. Results indicate that magnetite micro-solid-phase extraction with gas chromatography and mass spectrometry is a convenient, fast, and economical method for the extraction and determination of amitriptyline and chlorpromazine in biological samples. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  5. Clinical and Biological Characteristics of 40 Patients With Neurosyphilis and Evaluation of Treponema pallidum Nested Polymerase Chain Reaction in Cerebrospinal Fluid Samples.

    Science.gov (United States)

    Vanhaecke, Clélia; Grange, Philippe; Benhaddou, Nadjet; Blanche, Philippe; Salmon, Dominique; Parize, Perrine; Lortholary, Olivier; Caumes, Eric; Pelloux, Isabelle; Epaulard, Olivier; Guinard, Jérôme; Dupin, Nicolas

    2016-11-01

     Syphilis remains a significant public health problem. We conducted a prospective study to define more precisely the clinical and biological characteristics of patients with neurosyphilis (NS), and we assessed the diagnostic value of nested polymerase chain reaction (PCR) testing for Treponema pallidum in cerebrospinal fluid (CSF) samples.  From 2001 to 2013, we included 40 patients (90% men; 45% infected with human immunodeficiency virus) with NS, defined as syphilis with neurological and/or ophthalmological symptoms and CSF abnormalities.  Thirty patients (75%) had early, 5 (12.5%) had late, and 5 had meningovascular NS. Twenty-four patients (80%) with early NS had ophthalmological symptoms, 14 (47%) had neurological symptoms, and 8 (26%) had both. All patients with meningovascular NS had only neurological symptoms. All patients with late NS had neurological symptoms, and 2 (40%) also had ocular symptoms. Ophthalmological symptoms were present in 65% of all patients with NS, and neurological symptoms in 60%. Seventeen patients (42.5%) had CSF white blood cell counts >20/μL (mean, 57/μL), and 27 (67.5%) had high CSF protein levels (>0.5 g/L; mean value, 1 g/L). CSF PCR results were positive in 42%, and CSF VDRL results in 30%. The nested PCR assay had an overall sensitivity of 42.5%, a specificity of 97%, a positive predictive value of 77%, and a negative predictive value of 86%.  Early NS is the most frequent presentation, with an overrepresentation of polymorphous ophthalmological symptoms. PCR is highly specific and of potential value when used with other biological parameters. © The Author 2016. Published by Oxford University Press for the Infectious Diseases Society of America. All rights reserved. For permissions, e-mail journals.permissions@oup.com.

  6. Is the fluid mosaic (and the accompanying raft hypothesis a suitable model to describe fundamental features of biological membranes? What may be missing?

    Directory of Open Access Journals (Sweden)

    Luis Alberto Bagatolli

    2013-11-01

    Full Text Available The structure, dynamics, and stability of lipid bilayers are controlled by thermodynamic forces, leading to overall tensionless membranes with a distinct lateral organization and a conspicuous lateral pressure profile. Bilayers are also subject to built-in curvature-stress instabilities that may be released locally or globally in terms of morphological changes leading to the formation of non-lamellar and curved structures. A key controller of the bilayer’s propensity to form curved structures is the average molecular shape of the different lipid molecules. Via the curvature stress, molecular shape mediates a coupling to membrane-protein function and provides a set of physical mechanisms for formation of lipid domains and laterally differentiated regions in the plane of the membrane. Unfortunately, these relevant physical features of membranes are often ignored in the most popular models for biological membranes. Results from a number of experimental and theoretical studies emphasize the significance of these fundamental physical properties and call for a refinement of the fluid mosaic model (and the accompanying raft hypothesis.

  7. A rapid MCM-41 dispersive micro-solid phase extraction coupled with LC/MS/MS for quantification of ketoconazole and voriconazole in biological fluids.

    Science.gov (United States)

    Yahaya, Noorfatimah; Sanagi, Mohd Marsin; Abd Aziz, Noorizan; Wan Ibrahim, Wan Aini; Nur, Hadi; Loh, Saw Hong; Kamaruzaman, Sazlinda

    2017-02-01

    A rapid dispersive micro-solid phase extraction (D-μ-SPE) combined with LC/MS/MS method was developed and validated for the determination of ketoconazole and voriconazole in human urine and plasma samples. Synthesized mesoporous silica MCM-41 was used as sorbent in d-μ-SPE of the azole compounds from biological fluids. Important D-μ-SPE parameters, namely type desorption solvent, extraction time, sample pH, salt addition, desorption time, amount of sorbent and sample volume were optimized. Liquid chromatographic separations were carried out on a Zorbax SB-C 18 column (2.1 × 100 mm, 3.5 μm), using a mobile phase of acetonitrile-0.05% formic acid in 5 mm ammonium acetate buffer (70:30, v/v). A triple quadrupole mass spectrometer with positive ionization mode was used for the determination of target analytes. Under the optimized conditions, the calibration curves showed good linearity in the range of 0.1-10,000 μg/L with satisfactory limit of detection (≤0.06 μg/L) and limit of quantitation (≤0.3 μg/L). The proposed method also showed acceptable intra- and inter-day precisions for ketoconazole and voriconazole from urine and human plasma with RSD ≤16.5% and good relative recoveries in the range 84.3-114.8%. The MCM-41-D-μ-SPE method proved to be rapid and simple and requires a small volume of organic solvent (200 μL); thus it is advantageous for routine drug analysis. Copyright © 2016 John Wiley & Sons, Ltd.

  8. Analytical methods for the determination of mixtures of bisphenols and derivatives in human and environmental exposure sources and biological fluids. A review

    Energy Technology Data Exchange (ETDEWEB)

    Caballero-Casero, N.; Lunar, L.; Rubio, S., E-mail: qa1rubrs@uco.es

    2016-02-18

    Bisphenol A (BPA) is ubiquitous in humans and the environment. Its potential adverse effects through genomic and non-genomic pathways have fostered BPA replacement by bisphenol analogs that, unfortunately, exert similar adverse effects. Many of these analogs, as well as their derivatives, have already found in humans and the environment and major concerns have arisen over their low dose- and mixture-related effects. This review aims to discuss the characteristics of the main analytical methods reported so far for the determination of mixtures of bisphenol analogs and/or derivatives in human and environmental exposure sources and biological fluids. Approaches followed for removal of background contamination, sample preparation and separation and detection of mixtures of bisphenols and derivatives are critically discussed. Sample treatment is matrix-dependent and common steps include analyte isolation, removal of interferences, evaporation of the extracts and solvent reconstitution. Separation and quantification has been almost exclusively carried out by liquid chromatography tandem mass spectrometry (LC-MS/MS) or gas chromatography mass spectrometry (GC–MS), in the last case prior derivatization, but LC-fluorescence detection has also found some applications. Main characteristics, advantages and drawbacks of these methods will be comparatively discussed. Although at an early stage, some approaches for the assessment of the risk to mixtures of bisphenols, mainly based on the combination of chemical target analysis and toxicity evaluation, have been already applied and they will be here presented. Current knowledge gaps hindering a reliable assessment of human and environmental risk to mixtures of bisphenols and derivatives will be outlined. - Highlights: • Analytical methods for the (bio)monitoring of mixtures of bisphenols are reviewed. • LC and CG coupled to MS are the preferred techniques. • Method-dependent sample treatments are required to remove matrix

  9. Fluid Flow at Branching Junctions

    OpenAIRE

    Sochi, Taha

    2013-01-01

    The flow of fluids at branching junctions plays important kinematic and dynamic roles in most biological and industrial flow systems. The present paper highlights some key issues related to the flow of fluids at these junctions with special emphasis on the biological flow networks particularly blood transportation vasculature.

  10. Determination of ibogaine and noribogaine in biological fluids and hair by LC-MS/MS after Tabernanthe iboga abuse Iboga alkaloids distribution in a drowning death case.

    Science.gov (United States)

    Chèze, Marjorie; Lenoan, Aurélie; Deveaux, Marc; Pépin, Gilbert

    2008-03-21

    Tabernanthe iboga belongs to the Apocynaceae family. In this study, we report the case of a 37-year-old black male working as a security agent in Paris and found dead naked on the beach in Gabon after consumption of iboga. Autopsy revealed a drowning fatality and a myocardial abnormality (myocardial bridging). Samples of blood, urine, bile, gastric content, liver, lungs, vitreous, spleen and hair were taken. Biological fluids were liquid-liquid extracted with saturated NH4Cl pH 9.5 and methylene chloride/isopropanol (95/5, v/v) in presence of clonazepam-d(4), used as internal standard. After decontamination with dichloromethane, hair was cut into small pieces then sonicated for 2h in saturated NH4Cl pH 9.5 before extraction by methylene chloride/isopropanol (95/5, v/v). After evaporation the residues were reconstituted in methanol/ACN/formate buffer pH 3, from which 10 microL were injected into an ODB Uptisphere C(18) column (150 mm x 2.1mm, 5 microm) and eluted with a gradient of acetonitrile and formate buffer delivered at a flow rate of 200 microL/min. A Quantum Ultra triple-quadrupole mass spectrometer was used for analyses. Ionization was achieved using electrospray in the positive ionization mode (ESI). For each compound, detection was related to three daughter ions (ibogaine: m/z 311.4-->122.1, 174.1 and 188.1; noribogaine: m/z 297.4-->122.1, 159.1 and 160.1; clonazepam-d(4): m/z 319.9-->218.1, 245.1 and 274.1). Ibogaine and noribogaine were detected in all autopsy samples. Hair segmentation was not possible as hair was very short and frizzy. Concentrations of 1.2 and 2.5 ng/mg, respectively were detected. Neither other licit or illicit drugs nor alcohol were found. The presence of ibogaine and noribogaine in all autopsy samples was consistent with the recent absorption of Tabernanthe iboga, which was assumed to be responsible of the drowning fatality. The history of exposure, regarding hair analysis, is discussed. LC-MS/MS appears to be the best method for

  11. Sphere based fluid systems

    Science.gov (United States)

    Elleman, Daniel D. (Inventor); Wang, Taylor G. (Inventor)

    1989-01-01

    Systems are described for using multiple closely-packed spheres. In one system for passing fluid, a multiplicity of spheres lie within a container, with all of the spheres having the same outside diameter and with the spheres being closely nested in one another to create multiple interstitial passages of a known size and configuration and smooth walls. The container has an inlet and outlet for passing fluid through the interstitial passages formed between the nested spheres. The small interstitial passages can be used to filter out material, especially biological material such as cells in a fluid, where the cells can be easily destroyed if passed across sharp edges. The outer surface of the spheres can contain a material that absorbs a constitutent in the flowing fluid, such as a particular contamination gas, or can contain a catalyst to chemically react the fluid passing therethrough, the use of multiple small spheres assuring a large area of contact of these surfaces of the spheres with the fluid. In a system for storing and releasing a fluid such as hydrogen as a fuel, the spheres can include a hollow shell containing the fluid to be stored, and located within a compressable container that can be compressed to break the shells and release the stored fluid.

  12. Semianalytical Solution for the Deformation of an Elastic Layer under an Axisymmetrically Distributed Power-Form Load: Application to Fluid-Jet-Induced Indentation of Biological Soft Tissues

    Directory of Open Access Journals (Sweden)

    Minhua Lu

    2017-01-01

    Full Text Available Fluid-jet-based indentation is used as a noncontact excitation technique by systems measuring the mechanical properties of soft tissues. However, the application of these devices has been hindered by the lack of theoretical solutions. This study developed a mathematical model for testing the indentation induced by a fluid jet and determined a semianalytical solution. The soft tissue was modeled as an elastic layer bonded to a rigid base. The pressure of the fluid jet impinging on the soft tissue was assumed to have a power-form function. The semianalytical solution was verified in detail using finite-element modeling, with excellent agreement being achieved. The effects of several parameters on the solution behaviors are reported, and a method for applying the solution to determine the mechanical properties of soft tissues is suggested.

  13. Development of ovarian hyperstimulation syndrome: interrogation of key proteins and biological processes in human follicular fluid of women undergoing in vitro fertilization

    Czech Academy of Sciences Publication Activity Database

    Jarkovská, Karla; Skalníková, Helena; Halada, Petr; Hrabáková, Rita; Moos, J.; Rezábek, K.; Gadher, S. J.; Kovářová, Hana

    2011-01-01

    Roč. 17, č. 11 (2011), s. 679-692 ISSN 1360-9947 Institutional research plan: CEZ:AV0Z50450515; CEZ:AV0Z50200510 Keywords : biomarkers * computer modelling * human follicular fluid Subject RIV: FK - Gynaecology, Childbirth Impact factor: 3.852, year: 2011

  14. Métodos de extração e/ou concentração de compostos encontrados em fluidos biológicos para posterior determinação cromatográfica Methods of extraction and/or concentration of compounds found in biological fluids for subsequent chromatographic determination

    Directory of Open Access Journals (Sweden)

    Sonia C. N. Queiroz

    2001-02-01

    Full Text Available When organic compounds present in biological fluids are analysed by chromatographic methods, it is generally necessary to carry out a prior sample preparation due the high complexity of this type of sample, especially when the compounds to be determinated are found in very low concentrations. This article describes some of the principal methods for sample preparation in analyses of substances present in biological fluids. The methods include liquid-liquid extraction, solid phase extraction, supercritical fluid extraction and extraction using solid and liquid membranes. The advantages and disadvantages of these methods are discussed.

  15. Biological detector and method

    Science.gov (United States)

    Sillerud, Laurel; Alam, Todd M; McDowell, Andrew F

    2013-02-26

    A biological detector includes a conduit for receiving a fluid containing one or more magnetic nanoparticle-labeled, biological objects to be detected and one or more permanent magnets or electromagnet for establishing a low magnetic field in which the conduit is disposed. A microcoil is disposed proximate the conduit for energization at a frequency that permits detection by NMR spectroscopy of whether the one or more magnetically-labeled biological objects is/are present in the fluid.

  16. Proteome Mining of Human Follicular Fluid Reveals a Crucial Role of Complement Cascade and Key Biological Pathways in Women Undergoing in Vitro Fertilization

    Czech Academy of Sciences Publication Activity Database

    Jarkovská, Karla; Martinková, Jiřina; Lišková, Lucie; Halada, Petr; Moos, J.; Rezábek, K.; Gadher, S. J.; Kovářová, Hana

    2010-01-01

    Roč. 9, č. 3 (2010), s. 1289-1301 ISSN 1535-3893 R&D Projects: GA MZd(CZ) NS9781; GA AV ČR 1QS500450568 Institutional research plan: CEZ:AV0Z50450515; CEZ:AV0Z50200510 Keywords : Human follicular fluid * plasma * assisted reproduction Subject RIV: FK - Gynaecology, Childbirth Impact factor: 5.460, year: 2010

  17. Fluid Mechanics.

    Science.gov (United States)

    Drazin, Philip

    1987-01-01

    Outlines the contents of Volume II of "Principia" by Sir Isaac Newton. Reviews the contributions of subsequent scientists to the physics of fluid dynamics. Discusses the treatment of fluid mechanics in physics curricula. Highlights a few of the problems of modern research in fluid dynamics. Shows that problems still remain. (CW)

  18. Fluid Interfaces

    DEFF Research Database (Denmark)

    Hansen, Klaus Marius

    2001-01-01

    Fluid interaction, interaction by the user with the system that causes few breakdowns, is essential to many user interfaces. We present two concrete software systems that try to support fluid interaction for different work practices. Furthermore, we present specificity, generality, and minimality...... as design goals for fluid interfaces....

  19. Fluid dynamics of dilatant fluid

    DEFF Research Database (Denmark)

    Nakanishi, Hiizu; Nagahiro, Shin-ichiro; Mitarai, Namiko

    2012-01-01

    A dense mixture of granules and liquid often shows a severe shear thickening and is called a dilatant fluid. We construct a fluid dynamics model for the dilatant fluid by introducing a phenomenological state variable for a local state of dispersed particles. With simple assumptions for an equation...

  20. Asymmetric viscoelastic flow through a porous channel with expanding or contracting walls: a model for transport of biological fluids through vessels.

    Science.gov (United States)

    Xinhui, Si; Liancun, Zheng; Xinxin, Zhang; Xinyi, Si; Min, Li

    2014-01-01

    In this article, the asymmetric viscoelastic fluid in a rectangular domain bounded by two porous moving channels with expanding or contracting walls is investigated. The governing equations are reduced to an ordinary equation by using suitable similar transformations. Homotopy analysis method is used to obtain the expression for velocity fields. The analytical solutions are influenced by the permeation Reynolds number Re, the wall expansion ratio [Formula: see text] and viscoelastic parameter [Formula: see text]. Graphs are sketched and the effects of some values of parameters, especially the expansion ratio and viscoelastic parameter, on the velocity fields are discussed in detail.

  1. Selective quantitative bioanalysis of proteins in biological fluids by on-line immunoaffinity chromatography-protein digestion-liquid chromatography-mass spectrometry

    NARCIS (Netherlands)

    Hoos, J.S.; Sudergat, H.; Hoelck, J.P.; Stahl, M.; de Vlieger, J.S.B.; Niessen, W.M.A.; Lingeman, H.; Irth, H.

    2006-01-01

    A quantitative method for the determination of proteins in complex biological matrices has been developed based on the selectivity of antibodies for sample purification followed by proteolytic digestion and quantitative mass spectrometry. An immunosorbent of polyclonal anti-bovine serum albumin

  2. Fluids engineering

    International Nuclear Information System (INIS)

    Anon.

    1991-01-01

    Fluids engineering has played an important role in many applications, from ancient flood control to the design of high-speed compact turbomachinery. New applications of fluids engineering, such as in high-technology materials processing, biotechnology, and advanced combustion systems, have kept up unwaining interest in the subject. More accurate and sophisticated computational and measurement techniques are also constantly being developed and refined. On a more fundamental level, nonlinear dynamics and chaotic behavior of fluid flow are no longer an intellectual curiosity and fluid engineers are increasingly interested in finding practical applications for these emerging sciences. Applications of fluid technology to new areas, as well as the need to improve the design and to enhance the flexibility and reliability of flow-related machines and devices will continue to spur interest in fluids engineering. The objectives of the present seminar were: to exchange current information on arts, science, and technology of fluids engineering; to promote scientific cooperation between the fluids engineering communities of both nations, and to provide an opportunity for the participants and their colleagues to explore possible joint research programs in topics of high priority and mutual interest to both countries. The Seminar provided an excellent forum for reviewing the current state and future needs of fluids engineering for the two nations. With the Seminar ear-marking the first formal scientific exchange between Korea and the United States in the area of fluids engineering, the scope was deliberately left broad and general

  3. Magnetite nanoparticles coated with covalently immobilized ionic liquids as a sorbent for extraction of non-steroidal anti-inflammatory drugs from biological fluids

    International Nuclear Information System (INIS)

    Amiri, Maryam; Yadollah, Yamini; Safari, Meysam; Asiabi, Hamid

    2016-01-01

    Magnetic core-shell nanoparticles (mag-NPs) of type SiO 2 -Fe 3 O 4 were covalently modified with the ionic liquid dimethyl octadecyl[3-(trimethoxysilyl propyl)]ammonium chloride. The NPs were characterized via FTIR and scanning electron microscopy and evaluated with respect to the extraction of the nonsteroidal anti-inflammatory drugs (NSAIDs) tolmetin, indometacin and naproxen from blood samples. Supercritical fluid extraction was used to eliminate matrix effects before extraction with the mag-NPs. The effects of pH value of sample solution, amount of adsorbent, times of adsorption and desorption, salt effect, type and volume of suitable solvent for desorption were optimized. Under optimum conditions, magnetic solid phase extraction (MSPE) resulted in limits of detection that range between 0.1 and 0.3 μg L −1 . In case of supercritical fluid extraction along with magnetic solid phase extraction (SFE- MSPE), the LODs ranged from 0.2 to 0.3 mg kg −1 . The analytical ranges for all of the NSAIDs varied within 0.2–15 mg kg -1 and 0.1–250 μg L −1 in the SFE-MSPE and MSPE methods, respectively. The relative standard deviations for the extraction of the NSAIDs from blood samples via SFE-MSPE are <10.2%. (author)

  4. N-glycan signatures identified in tumor interstitial fluid and serum of breast cancer patients - association with tumor biology and clinical outcome.

    Science.gov (United States)

    Terkelsen, Thilde; Haakensen, Vilde D; Saldova, Radka; Gromov, Pavel; Hansen, Merete Kjaer; Stöckmann, Henning; Lingjaerde, Ole Christian; Børresen-Dale, Anne-Lise; Papaleo, Elena; Helland, Åslaug; Rudd, Pauline M; Gromova, Irina

    2018-04-26

    Particular N-glycan structures are known to be associated with breast malignancies by coordinating various regulatory events within the tumor and corresponding microenvironment, thus implying that N-glycan patterns may be used for cancer stratification and as predictive or prognostic biomarkers. However, the association between N-glycans secreted by breast tumor and corresponding clinical relevance remain to be elucidated. We profiled N-glycans by HILIC UPLC across a discovery dataset composed of tumor interstitial fluids (TIF, n=85), paired normal interstitial fluids (NIF, n=54) and serum samples (n=28) followed by independent evaluation, with the ultimate goal of identifying tumor-related N-glycan patterns in blood of breast cancer patients. The segregation of N-linked oligosaccharides revealed 33 compositions, which exhibited differential abundances between TIF and NIF. TIFs were depleted of bisecting N-glycans, which are known to play essential roles in tumor suppression. An increased level of simple high mannose N-glycans in TIF strongly correlated with the presence of tumor infiltrating lymphocytes within tumor. At the same time, a low level of highly complex N-glycans in TIF inversely correlated with the presence of infiltrating lymphocytes within tumor. Survival analysis showed that patients exhibiting increased TIF abundance of GP24 had better outcomes, whereas low levels of GP10, GP23, GP38, and coreF were associated with poor prognosis. Levels of GP1, GP8, GP9, GP14, GP23, GP28, GP37, GP38, and coreF were significantly correlated between TIF and paired serum samples. Cross-validation analysis using an independent serum dataset supported the observed correlation between TIF and serum, for five out of nine N-glycan groups: GP8, GP9, GP14, GP23, and coreF. Collectively, our results imply that profiling of N-glycans from proximal breast tumor fluids is a promising strategy for determining tumor-derived glyco-signature(s) in the blood. N-glycans structures

  5. Fluid machinery

    International Nuclear Information System (INIS)

    Ha, Jae Hyeon; Son, Byeong Jin

    2001-04-01

    This book tells of definition and classification of fluid machinery, energy equation of incompressible fluid, principle of momentum, classification and structure of pump, size, safety of centrifugal pump, theory and operation of contraction pump, reciprocating pump, rotary pump, special pump, using of water power, classification of water turbine, impulse water turbine, reaction water turbine, pump water turbine, liquid movement apparatus, fluid type control machinery and solid and gas type pneumatic machine.

  6. Molecularly imprinted polymer for the selective extraction of cocaine and its metabolites, benzoylecgonine and ecgonine methyl ester, from biological fluids before LC-MS analysis.

    Science.gov (United States)

    Thibert, Valérie; Legeay, Patrice; Chapuis-Hugon, Florence; Pichon, Valérie

    2014-02-15

    Considering the important complexity of biological samples, a molecularly imprinted polymer (MIP) was applied to the selective extraction of cocaine and its two main metabolites, benzoylecgonine and ecgonine methyl ester from biological samples. The MIP was imprinted with cocaine and it was synthesized in acetonitrile with methacrylic acid as a functional monomer and ethylene glycol dimethacrylate as a crosslinker. The selectivity of the MIP was first assessed for the three target analytes in acetonitrile with recoveries higher than 80% on the MIP and lower than 30% on the non-imprinted polymer (NIP). The MIP was then evaluated for the selective extraction of these targets from real aqueous media, i.e. serum and urine samples. The pH adjustment of the sample as well as the optimization of the washing step led to a very selective extraction of cocaine from these media. A LOQ of 0.5ng/mL was obtained for cocaine in urine. Concerning cocaine metabolites, benzoylecgonine and ecgonine methyl ester, they were first extracted from urine by liquid-liquid extraction and the resulting extract was purified on the MIP. The results obtained with the MIP as compared to the LLE alone showed the great potential of the MIP extraction for the clean-up of the biological matrix. This procedure was tested for the extraction of the analytes from urine samples, leading to a very selective protocol with LOQs of 0.09ng/mL, 0.4ng/mL and 1.1ng/mL for cocaine, benzolecgonine and ecgonine methyl ester respectively in urine samples. Copyright © 2013 Elsevier B.V. All rights reserved.

  7. Schroedinger fluid

    International Nuclear Information System (INIS)

    Kan, K.K.

    1983-01-01

    The relationship of nuclear internal flow and collective inertia, the difference of this flow from that of a classical fluid, and the approach of this flow to rigid flow in independent-particle model rotation are elucidated by reviewing the theory of Schroedinger fluid and its implications for collective vibration and rotation. (author)

  8. Fluid Dynamics

    DEFF Research Database (Denmark)

    Brorsen, Michael

    These lecture notes are intended mainly for the 7th semester course "Fluid Dynamics" offered by the Study Committee on Civil Engineering, Aalborg University.......These lecture notes are intended mainly for the 7th semester course "Fluid Dynamics" offered by the Study Committee on Civil Engineering, Aalborg University....

  9. Squirming through shear thinning fluids

    Science.gov (United States)

    Datt, Charu; Zhu, Lailai; Elfring, Gwynn J.; Pak, On Shun

    2015-11-01

    Many microorganisms find themselves surrounded by fluids which are non-Newtonian in nature; human spermatozoa in female reproductive tract and motile bacteria in mucosa of animals are common examples. These biological fluids can display shear-thinning rheology whose effects on the locomotion of microorganisms remain largely unexplored. Here we study the self-propulsion of a squirmer in shear-thinning fluids described by the Carreau-Yasuda model. The squirmer undergoes surface distortions and utilizes apparent slip-velocities around its surface to swim through a fluid medium. In this talk, we will discuss how the nonlinear rheological properties of a shear-thinning fluid affect the propulsion of a swimmer compared with swimming in Newtonian fluids.

  10. Biological characterization of the skin of shortfin mako shark Isurus oxyrinchus and preliminary study of the hydrodynamic behaviour through computational fluid dynamics.

    Science.gov (United States)

    Díez, G; Soto, M; Blanco, J M

    2015-07-01

    This study characterized the morphology, density and orientation of the dermal denticles along the body of a shortfin mako shark Isurus oxyrinchus and identified the hydrodynamic parameters of its body through a computational fluid-dynamics model. The study showed a great variability in the morphology, size, shape, orientation and density of dermal denticles along the body of I. oxyrinchus. There was a significant higher density in dorsal and ventral areas of the body and their highest angular deviations were found in the lower part of the mouth and in the areas between the pre-caudal pit and the second dorsal and pelvic fins. A detailed three-dimensional geometry from a scanned body of a shark was carried out to evaluate the hydrodynamic properties such as drag coefficient, lift coefficient and superficial (skin) friction coefficient of the skin together with flow velocity field, according to different roughness coefficients simulating the effect of the dermal denticles. This preliminary approach contributed to detailed information of the denticle interactions. As the height of the denticles was increased, flow velocity and the effect of lift decreased whereas drag increased. The highest peaks of skin friction coefficient were observed around the pectoral fins. © 2015 The Fisheries Society of the British Isles.

  11. A Novel HPLC Method for the Concurrent Analysis and Quantitation of Seven Water-Soluble Vitamins in Biological Fluids (Plasma and Urine): A Validation Study and Application

    Science.gov (United States)

    Grotzkyj Giorgi, Margherita; Howland, Kevin; Martin, Colin; Bonner, Adrian B.

    2012-01-01

    An HPLC method was developed and validated for the concurrent detection and quantitation of seven water-soluble vitamins (C, B1, B2, B5, B6, B9, B12) in biological matrices (plasma and urine). Separation was achieved at 30°C on a reversed-phase C18-A column using combined isocratic and linear gradient elution with a mobile phase consisting of 0.01% TFA aqueous and 100% methanol. Total run time was 35 minutes. Detection was performed with diode array set at 280 nm. Each vitamin was quantitatively determined at its maximum wavelength. Spectral comparison was used for peak identification in real samples (24 plasma and urine samples from abstinent alcohol-dependent males). Interday and intraday precision were vitamins. Recovery percentages ranged from 93% to 100%. PMID:22536136

  12. A Novel HPLC Method for the Concurrent Analysis and Quantitation of Seven Water-Soluble Vitamins in Biological Fluids (Plasma and Urine: A Validation Study and Application

    Directory of Open Access Journals (Sweden)

    Margherita Grotzkyj Giorgi

    2012-01-01

    Full Text Available An HPLC method was developed and validated for the concurrent detection and quantitation of seven water-soluble vitamins (C, B1, B2, B5, B6, B9, B12 in biological matrices (plasma and urine. Separation was achieved at 30°C on a reversed-phase C18-A column using combined isocratic and linear gradient elution with a mobile phase consisting of 0.01% TFA aqueous and 100% methanol. Total run time was 35 minutes. Detection was performed with diode array set at 280 nm. Each vitamin was quantitatively determined at its maximum wavelength. Spectral comparison was used for peak identification in real samples (24 plasma and urine samples from abstinent alcohol-dependent males. Interday and intraday precision were <4% and <7%, respectively, for all vitamins. Recovery percentages ranged from 93% to 100%.

  13. Solid-phase extraction based on hydrophilic interaction liquid chromatography with acetone as eluent for eliminating matrix effects in the analysis of biological fluids by LC-MS.

    Science.gov (United States)

    Van Damme, T; Lachová, M; Lynen, F; Szucs, R; Sandra, P

    2014-01-01

    Analysis of drugs and metabolites in biological matrices such as blood or plasma by LC-MS is routinely challenged by the presence of large quantities of competing molecules for ionization in soft ionization sources, such as proteins and phospholipids. While the former can easily be removed by protein precipitation, pre-analytical extraction of the latter is necessary because they show very high retention in reversed-phase LC resulting in long analysis times or in ion suppression effects when not eluted before the next runs. A novel HILIC-based SPE approach, making use of silica cartridges and of acetone as organic solvent, is introduced as a potent alternative to current commercial methods for phospholipid removal. The methodology was developed and tested for a broad polarity range of pharmaceutical solutes (log P from 0 to 6.6) and broad applicability can therefore be envisaged.

  14. A comprehensive review of the published assays for the quantitation of the immunosuppressant drug mycophenolic acid and its glucuronidated metabolites in biological fluids

    DEFF Research Database (Denmark)

    Syed, Muzeeb; Srinivas, Nuggehally R

    2016-01-01

    using the choices in the literature. While the chemical methods involving high-performance liquid chromatography (HPLC) or LC coupled with triple quadrupole mass spectrometry (LC-MS/MS) are popular, enzymatic assays, in spite of their higher bias, have been used for the routine drug monitoring of MPA......Therapeutic use of mycophenolic acid (MPA) is steadily on the rise in combination with other immunosuppressant drugs in transplantation patients. The biotransformation of MPA resulted in the formation of glucuronide metabolites, MPAG and AcMPAG. There are a plethora of assays validated...... for the analysis of MPA alone or with MPAG/AcMPAG in various biological specimens including plasma/serum, urine, ultrafiltrate, saliva, PBMC, dried blood spots, tissue extract, tumor biopsies and vitreous humor. Based on the need for experimental work, a proper choice of the assay and internal standard may be made...

  15. Active chiral fluids.

    Science.gov (United States)

    Fürthauer, S; Strempel, M; Grill, S W; Jülicher, F

    2012-09-01

    Active processes in biological systems often exhibit chiral asymmetries. Examples are the chirality of cytoskeletal filaments which interact with motor proteins, the chirality of the beat of cilia and flagella as well as the helical trajectories of many biological microswimmers. Here, we derive constitutive material equations for active fluids which account for the effects of active chiral processes. We identify active contributions to the antisymmetric part of the stress as well as active angular momentum fluxes. We discuss four types of elementary chiral motors and their effects on a surrounding fluid. We show that large-scale chiral flows can result from the collective behavior of such motors even in cases where isolated motors do not create a hydrodynamic far field.

  16. Fluid biopsy for circulating tumor cell identification in patients with early-and late-stage non-small cell lung cancer: a glimpse into lung cancer biology

    International Nuclear Information System (INIS)

    Wendel, Marco; Kolatkar, Anand; Honnatti, Meghana; Cho, Edward H; Marrinucci, Dena; Kuhn, Peter

    2012-01-01

    Circulating tumor cell (CTC) counts are an established prognostic marker in metastatic prostate, breast and colorectal cancer, and recent data suggest a similar role in late stage non-small cell lung cancer (NSCLC). However, due to sensitivity constraints in current enrichment-based CTC detection technologies, there are few published data about CTC prevalence rates and morphologic heterogeneity in early-stage NSCLC, or the correlation of CTCs with disease progression and their usability for clinical staging. We investigated CTC counts, morphology and aggregation in early stage, locally advanced and metastatic NSCLC patients by using a fluid-phase biopsy approach that identifies CTCs without relying on surface-receptor-based enrichment and presents them in sufficiently high definition (HD) to satisfy diagnostic pathology image quality requirements. HD-CTCs were analyzed in blood samples from 78 chemotherapy-naïve NSCLC patients. 73% of the total population had a positive HD-CTC count (>0 CTC in 1 mL of blood) with a median of 4.4 HD-CTCs mL −1 (range 0–515.6) and a mean of 44.7 (±95.2) HD-CTCs mL −1 . No significant difference in the medians of HD-CTC counts was detected between stage IV (n = 31, range 0–178.2), stage III (n = 34, range 0–515.6) and stages I/II (n = 13, range 0–442.3). Furthermore, HD-CTCs exhibited a uniformity in terms of molecular and physical characteristics such as fluorescent cytokeratin intensity, nuclear size, frequency of apoptosis and aggregate formation across the spectrum of staging. Our results demonstrate that despite stringent morphologic inclusion criteria for the definition of HD-CTCs, the HD-CTC assay shows high sensitivity in the detection and characterization of both early- and late-stage lung cancer CTCs. Extensive studies are warranted to investigate the prognostic value of CTC profiling in early-stage lung cancer. This finding has implications for the design of extensive studies examining screening, therapy and

  17. An integrated methodological approach to the computer-assisted gas chromatographic screening of basic drugs in biological fluids using nitrogen selective detection.

    Science.gov (United States)

    Dugal, R; Massé, R; Sanchez, G; Bertrand, M J

    1980-01-01

    This paper presents the methodological aspects of a computerized system for the gas-chromatographic screening and primary identification of central nervous system stimulants and narcotic analgesics (including some of their respective metabolites) extracted from urine. The operating conditions of a selective nitrogen detector for optimized analytical functions are discussed, particularly the effect of carrier and fuel gas on the detector's sensitivity to nitrogen-containing molecules and discriminating performance toward biological matrix interferences. Application of simple extraction techniques, combined with rapid derivatization procedures, computer data acquisition, and reduction of chromatographic data are presented. Results show that this system approach allows for the screening of several drugs and their metabolites in a short amount of time. The reliability and stability of the system have been tested by analyzing several thousand samples for doping control at major international sporting events and for monitoring drug intake in addicts participating in a rehabilitation program. Results indicate that these techniques can be used and adapted to many different analytical toxicology situations.

  18. A comprehensive review of the published assays for the quantitation of the immunosuppressant drug mycophenolic acid and its glucuronidated metabolites in biological fluids.

    Science.gov (United States)

    Syed, Muzeeb; Srinivas, Nuggehally R

    2016-05-01

    Therapeutic use of mycophenolic acid (MPA) is steadily on the rise in combination with other immunosuppressant drugs in transplantation patients. The biotransformation of MPA resulted in the formation of glucuronide metabolites, MPAG and AcMPAG. There are a plethora of assays validated for the analysis of MPA alone or with MPAG/AcMPAG in various biological specimens including plasma/serum, urine, ultrafiltrate, saliva, PBMC, dried blood spots, tissue extract, tumor biopsies and vitreous humor. Based on the need for experimental work, a proper choice of the assay and internal standard may be made using the choices in the literature. While the chemical methods involving high-performance liquid chromatography (HPLC) or LC coupled with triple quadrupole mass spectrometry (LC-MS/MS) are popular, enzymatic assays, in spite of their higher bias, have been used for the routine drug monitoring of MPA. The objectives of the present review are: (a) to provide a focused systematic compilation of the HPLC or LC-MS/MS methods for MPA, MPAG and/or AcMPAG published in the last decade (2005 to current) to enable visual comparison of the methods; (b) to compare and contrast a few enzymatic assays with those of the chemical methods; and (c) to discuss relevant issues/limitations and perspectives on select assays under various subheadings. Copyright © 2016 John Wiley & Sons, Ltd.

  19. A Protocol for Improved Precision and Increased Confidence in Nanoparticle Tracking Analysis Concentration Measurements between 50 and 120 nm in Biological Fluids

    Directory of Open Access Journals (Sweden)

    Martin E. M. Parsons

    2017-11-01

    Full Text Available Nanoparticle tracking analysis (NTA can be used to quantitate extracellular vesicles (EVs in biological samples and is widely considered a useful diagnostic tool to detect disease. However, accurately profiling EVs can be challenging due to their small size and heterogeneity. Here, we aimed to provide a protocol to facilitate high-precision particle quantitation by NTA in plasma, the supernatant of activated purified platelets [the platelet releasate (PR] and in serum, to increase confidence in NTA particle enumeration. The overall variance and the precision of NTA measurements were quantified by root mean square error and relative standard error. Using a bootstrapping approach, we found that increasing video replicates from 5 s × 60 s to 25 s × 60 s captures led to a reduction in overall variance and a reproducible increase in the precision of NTA particle-concentration quantitation for all three biofluids. We then validated our approach in an extended cohort of 32 healthy donors. Our results indicate that for vesicles sized between 50 and 120 nm, the precision of routine NTA measurements in serum, plasma, and PR can be significantly improved by increasing the number of video replicates captured. Our protocol provides a common platform to statistical compare particle size distribution profiles in the exosomal-vesicle size range across a variety of biofluids and in both healthy donor and patient groups.

  20. Development and validation of a liquid chromatography-MS/MS method for simultaneous quantification of tenofovir and efavirenz in biological tissues and fluids.

    Science.gov (United States)

    Barreiros, Luisa; Cunha-Reis, Cassilda; Silva, Eduarda M P; Carvalho, Joana R B; das Neves, José; Sarmento, Bruno; Segundo, Marcela A

    2017-03-20

    Millions of people worldwide live with human immunodeficiency virus (HIV) infection thus justifying the continuous search for new prevention and treatment strategies, including topical microbicide products combining antiretroviral drugs (ARVs) such as tenofovir (TFV) and efavirenz (EFV). Therefore, the aim of this work was to develop and validate a high performance liquid chromatography method coupled to triple quadrupole-tandem mass spectrometry (HPLC-MS/MS) for the quantification of TFV and EFV in biological matrices (mouse vaginal tissue, vaginal lavage and blood plasma). Chromatographic separation was achieved using a reversed phase C18 column (3μm, 100×2.1mm) at 45°C and elution in gradient mode using a combination of 0.1% (v/v) formic acid in water and 0.1% (v/v) formic acid in acetonitrile at 0.35mLmin -1 . Total run time was 9min, with retention time of 2.8 and 4.1min for TFV and EFV, respectively. The MS was operated in positive ionization mode (ESI+) for TFV and in negative ionization mode (ESI-) for EFV detection. Data were acquired in selected reaction monitoring (SRM) mode and deuterated ARVs were employed as internal standards. Calibration curves were linear for ARV concentrations ranging from 4 to 500ngmL -1 with LOD and LOQ for both analytes ≤0.4 and ≤0.7ngmL -1 in sample extracts, respectively. The method was found to be specific, accurate (96.0-106.0% of nominal values) and precise (RSDfluids were ≥88.4%. Matrix effects were observed for EFV determination in tissue and plasma extracts but compensated by the use of deuterated internal standards. The proposed methodology was successfully applied to a pharmacokinetic study following intravaginal administration of both ARVs. Copyright © 2016 Elsevier B.V. All rights reserved.

  1. Hollow fiber-based liquid phase microextraction combined with high-performance liquid chromatography for extraction and determination of some antidepressant drugs in biological fluids.

    Science.gov (United States)

    Esrafili, Ali; Yamini, Yadollah; Shariati, Shahab

    2007-12-05

    The applicability of hollow fiber-based liquid phase microextraction (HF-LPME) was evaluated for the extraction and preconcentration of three antidepressant drugs (amitriptyline, imipramine and sertraline) prior to their determination by HPLC-UV. The target drugs were extracted from 11.0 mL of aqueous solution with pH 12.0 (source phase) into an organic extracting solvent (n-dodecane) impregnated in the pores of a hollow fiber and finally back extracted into 24 microL of aqueous solution located inside the lumen of the hollow fiber and adjusted to pH 2.1 using 0.1M of H3PO4 (receiving phase). The extraction was performed due to pH gradient between the inside and outside of the hollow fiber membrane. In order to obtain high extraction efficiency, the parameters affecting the HF-LPME including pH of the source and receiving phases, the type of organic phase, ionic strength and volume of the source phase, stirring rate and extraction time were studied and optimized. Under the optimized conditions, enrichment factors up to 300 were achieved and the relative standard deviation (R.S.D.%) of the method was in the range of 2-12%. The calibration curves were obtained in the range of 5-500 microg L(-1) with reasonable linearity (R2>0.998) and the limits of detection (LODs) ranged between 0.5 and 0.7 microg L(-1) (based on S/N=3). Finally, the applicability of the proposed method was evaluated by extraction and determination of the drugs in urine, plasma and tap water samples. The results indicated that hollow fiber microextraction method has excellent clean-up and high-preconcentration factor and can be served as a simple and sensitive method for monitoring of antidepressant drugs in the biological samples.

  2. New-generation bar adsorptive microextraction (BAμE) devices for a better eco-user-friendly analytical approach-Application for the determination of antidepressant pharmaceuticals in biological fluids.

    Science.gov (United States)

    Ide, A H; Nogueira, J M F

    2018-05-10

    The present contribution aims to design new-generation bar adsorptive microextraction (BAμE) devices that promote an innovative and much better user-friendly analytical approach. The novel BAμE devices were lab-made prepared having smaller dimensions by using flexible nylon-based supports (7.5 × 1.0 mm) coated with convenient sorbents (≈ 0.5 mg). This novel advance allows effective microextraction and back-extraction ('only single liquid desorption step') stages as well as interfacing enhancement with the instrumental systems dedicated for routine analysis. To evaluate the achievements of these improvements, four antidepressant agents (bupropion, citalopram, amitriptyline and trazodone) were used as model compounds in aqueous media combined with liquid chromatography (LC) systems. By using an N-vinylpyrrolidone based-polymer phase good selectivity and efficiency were obtained. Assays performed on 25 mL spiked aqueous samples, yielded average recoveries in between 67.8 ± 12.4% (bupropion) and 88.3 ± 12.1% (citalopram), under optimized experimental conditions. The analytical performance also showed convenient precision (RSD  0.9820). The application of the proposed analytical approach on biological fluids showed negligible matrix effects by using the standard addition methodology. From the data obtained, the new-generation BAμE devices presented herein provide an innovative and robust analytical cycle, are simple to prepare, cost-effective, user-friendly and compatible with the current LC autosampler systems. Furthermore, the novel devices were designed to be disposable and used together with negligible amounts of organic solvents (100 μL) during back-extraction, in compliance with the green analytical chemistry principles. In short, the new-generation BAμE devices showed to be an eco-user-friendly approach for trace analysis of priority compounds in biological fluids and a versatile alternative over other well-stablished sorption

  3. Distribution of \\0x03949-Tetrahydrocannabinol and 11-Nor-9-Carboxy-\\0x03949-Tetrahydrocannabinol acid in postmortem biological fluids and tissues from pilots fatally injured in aviation accidents.

    Science.gov (United States)

    2013-12-01

    Despite a long history of research on the pharmacology of 9-tetrahydrocannabinol (THC), the primary active cannabinoid in marijuana, little is known of its distribution in postmortem fluids and tissues. This study presents postmortem fluid and tiss...

  4. Fluid Shifts

    Science.gov (United States)

    Stenger, M. B.; Hargens, A. R.; Dulchavsky, S. A.; Arbeille, P.; Danielson, R. W.; Ebert, D. J.; Garcia, K. M.; Johnston, S. L.; Laurie, S. S.; Lee, S. M. C.; hide

    2017-01-01

    Introduction. NASA's Human Research Program is focused on addressing health risks associated with long-duration missions on the International Space Station (ISS) and future exploration-class missions beyond low Earth orbit. Visual acuity changes observed after short-duration missions were largely transient, but now more than 50 percent of ISS astronauts have experienced more profound, chronic changes with objective structural findings such as optic disc edema, globe flattening and choroidal folds. These structural and functional changes are referred to as the visual impairment and intracranial pressure (VIIP) syndrome. Development of VIIP symptoms may be related to elevated intracranial pressure (ICP) secondary to spaceflight-induced cephalad fluid shifts, but this hypothesis has not been tested. The purpose of this study is to characterize fluid distribution and compartmentalization associated with long-duration spaceflight and to determine if a relation exists with vision changes and other elements of the VIIP syndrome. We also seek to determine whether the magnitude of fluid shifts during spaceflight, as well as any VIIP-related effects of those shifts, are predicted by the crewmember's pre-flight status and responses to acute hemodynamic manipulations, specifically posture changes and lower body negative pressure. Methods. We will examine a variety of physiologic variables in 10 long-duration ISS crewmembers using the test conditions and timeline presented in the figure below. Measures include: (1) fluid compartmentalization (total body water by D2O, extracellular fluid by NaBr, intracellular fluid by calculation, plasma volume by CO rebreathe, interstitial fluid by calculation); (2) forehead/eyelids, tibia, and calcaneus tissue thickness (by ultrasound); (3) vascular dimensions by ultrasound (jugular veins, cerebral and carotid arteries, vertebral arteries and veins, portal vein); (4) vascular dynamics by MRI (head/neck blood flow, cerebrospinal fluid

  5. Accumulation of single-strand breaks doses not result in double-strand DNA breaks: peculiarity of transcribing fragment of human ribosomal operon that allows its detection in biological fluids at the death of various cells in organism

    International Nuclear Information System (INIS)

    Vejko, N.N.; Spitkovskij, D.M.

    2000-01-01

    The evidences of stability of the human ribosomal gene in the transcribing range (TR-rDNA) to fragmentation are presented in two groups of experiments: 1) in the case of availability of the fragments in the cells of sectional corpse material (necrosis and apoptosis) and by pathologies accompanied by the cells death through the apoptosis or necrosis mechanism; 2) in the model experiments, wherein the separated genomes DNA is subjected to the impact of nucleases initiating single-strand breaks (SB), or chemical introduction with a subsequent comparative analysis of stability to fragmentation of various DNA sequences including TR-rDNA. The DNA solutions were subjected to γ-radiation with the dose rate of 4.8 Gy/min. It is shown that in spite of the great number of the SBs the TR-rDNA is characterized by increased stability to fragmentation, which makes it possible to propose this DNA fragment for application as a cell death marker in biological fluids [ru

  6. Fluid Mechanics

    Science.gov (United States)

    Pnueli, David; Gutfinger, Chaim

    1997-01-01

    This text is intended for the study of fluid mechanics at an intermediate level. The presentation starts with basic concepts, in order to form a sound conceptual structure that can support engineering applications and encourage further learning. The presentation is exact, incorporating both the mathematics involved and the physics needed to understand the various phenomena in fluid mechanics. Where a didactical choice must be made between the two, the physics prevails. Throughout the book the authors have tried to reach a balance between exact presentation, intuitive grasp of new ideas, and creative applications of concepts. This approach is reflected in the examples presented in the text and in the exercises given at the end of each chapter. Subjects treated are hydrostatics, viscous flow, similitude and order of magnitude, creeping flow, potential flow, boundary layer flow, turbulent flow, compressible flow, and non-Newtonian flows. This book is ideal for advanced undergraduate students in mechanical, chemical, aerospace, and civil engineering. Solutions manual available.

  7. Fluid dynamics

    CERN Document Server

    Ruban, Anatoly I

    This is the first book in a four-part series designed to give a comprehensive and coherent description of Fluid Dynamics, starting with chapters on classical theory suitable for an introductory undergraduate lecture course, and then progressing through more advanced material up to the level of modern research in the field. The present Part 1 consists of four chapters. Chapter 1 begins with a discussion of Continuum Hypothesis, which is followed by an introduction to macroscopic functions, the velocity vector, pressure, density, and enthalpy. We then analyse the forces acting inside a fluid, and deduce the Navier-Stokes equations for incompressible and compressible fluids in Cartesian and curvilinear coordinates. In Chapter 2 we study the properties of a number of flows that are presented by the so-called exact solutions of the Navier-Stokes equations, including the Couette flow between two parallel plates, Hagen-Poiseuille flow through a pipe, and Karman flow above an infinite rotating disk. Chapter 3 is d...

  8. Optimized LC-MS/MS Method for the High-throughput Analysis of Clinical Samples of Ivacaftor, Its Major Metabolites, and Lumacaftor in Biological Fluids of Cystic Fibrosis Patients.

    Science.gov (United States)

    Schneider, Elena K; Reyes-Ortega, Felisa; Li, Jian; Velkov, Tony

    2017-10-15

    Defects in the cystic fibrosis trans-membrane conductance regulator (CFTR) are the cause of cystic fibrosis (CF), a disease with life-threatening pulmonary manifestations. Ivacaftor (IVA) and ivacaftor-lumacaftor (LUMA) combination are two new breakthrough CF drugs that directly modulate the activity and trafficking of the defective CFTR-protein. However, there is still a dearth of understanding on pharmacokinetic/pharmacodynamic parameters and the pharmacology of ivacaftor and lumacaftor. The HPLC-MS technique for the simultaneous analysis of the concentrations of ivacaftor, hydroxymethyl-ivacaftor, ivacaftor-carboxylate, and lumacaftor in biological fluids in patients receiving standard ivacaftor or ivacaftor-lumacaftor combination therapy has previously been developed by our group and partially validated to FDA standards. However, to allow the high-throughput analysis of a larger number of patient samples, our group has optimized the reported method through the use of a smaller pore size reverse-phase chromatography column (2.6 µm, C8 100 Å; 50 x 2.1 mm) and a gradient solvent system (0-1 min: 40% B; 1-2 min: 40-70% B; 2-2.7 min: held at 70% B; 2.7-2.8 min: 70-90% B; 2.8-4.0 min: 90% B washing; 4.0-4.1 min: 90-40% B; 4.1-6.0 min: held at 40% B) instead of an isocratic elution. The goal of this study was to reduce the HPLC-MS analysis time per sample dramatically from ~15 min to only 6 min per sample, which is essential for the analysis of a large amount of patient samples. This expedient method will be of considerable utility for studies into the exposure-response relationships of these breakthrough CF drugs.

  9. Fluid mechanics

    International Nuclear Information System (INIS)

    Paraschivoiu, I.; Prud'homme, M.; Robillard, L.; Vasseur, P.

    2003-01-01

    This book constitutes at the same time theoretical and practical base relating to the phenomena associated with fluid mechanics. The concept of continuum is at the base of the approach developed in this work. The general advance proceeds of simple balances of forces as into hydrostatic to more complex situations or inertias, the internal stresses and the constraints of Reynolds are taken into account. This advance is not only theoretical but contains many applications in the form of solved problems, each chapter ending in a series of suggested problems. The major part of the applications relates to the incompressible flows

  10. Fluid Sounds

    DEFF Research Database (Denmark)

    and in architectural design. Aesthetics, psychoacoustics, perception, and cognition are all present in this expanding field embracing such categories as soundscape composition, sound art, sonic art, sound design, sound studies and auditory culture. Of greatest significance to the overall field is the investigation...... of sound, site and the social, and how the spatial, the visual, and the bodily interact in sonic environments, how they are constructed and how they are entangled in other practices. With the Seismograf special issue Fluid Sounds, we bring this knowledge into the dissemination of audio research itself...

  11. Determinação voltamétrica de metais em águas e fluidos biológicos empregando mineralização de amostras com radiação ultravioleta Voltammetric determination of metals in waters and biological fluids using sample mineralization with ultraviolet radiation

    Directory of Open Access Journals (Sweden)

    Leandro M. de Carvalho

    2008-01-01

    Full Text Available This work describes the optimization of pretreatment steps for the destruction of organic matter in samples of waters and biological fluids, by using an UV irradiation system with a high power UV radiation source (400 W. The efficiency of the system constructed for the photo-decomposition of samples of model waters, natural waters and biological fluids was investigated by performing recovery experiments of the metallic species Zn(II, Cd(II, Pb(II, Cu(II, Al(III and Fe(III. The use of UV irradiation allowed the liberation of metals bound to the organic matrix and the determination of the total content of elements in the samples.

  12. Principles of fluid mechanics

    International Nuclear Information System (INIS)

    Kreider, J.F.

    1985-01-01

    This book is an introduction on fluid mechanics incorporating computer applications. Topics covered are as follows: brief history; what is a fluid; two classes of fluids: liquids and gases; the continuum model of a fluid; methods of analyzing fluid flows; important characteristics of fluids; fundamentals and equations of motion; fluid statics; dimensional analysis and the similarity principle; laminar internal flows; ideal flow; external laminar and channel flows; turbulent flow; compressible flow; fluid flow measurements

  13. Gyroelastic fluids

    Energy Technology Data Exchange (ETDEWEB)

    Kerbel, G.D.

    1981-01-20

    A study is made of a scale model in three dimensions of a guiding center plasma within the purview of gyroelastic (also known as finite gyroradius-near theta pinch) magnetohydrodynamics. The (nonlinear) system sustains a particular symmetry called isorrhopy which permits the decoupling of fluid modes from drift modes. Isorrhopic equilibria are analyzed within the framework of geometrical optics resulting in (local) dispersion relations and ray constants. A general scheme is developed to evolve an arbitrary linear perturbation of a screwpinch equilibrium as an invertible integral transform (over the complete set of generalized eigenfunctions defined naturally by the equilibrium). Details of the structure of the function space and the associated spectra are elucidated. Features of the (global) dispersion relation owing to the presence of gyroelastic stabilization are revealed. An energy principle is developed to study the stability of the tubular screwpinch.

  14. Gyroelastic fluids

    International Nuclear Information System (INIS)

    Kerbel, G.D.

    1981-01-01

    A study is made of a scale model in three dimensions of a guiding center plasma within the purview of gyroelastic (also known as finite gyroradius-near theta pinch) magnetohydrodynamics. The (nonlinear) system sustains a particular symmetry called isorrhopy which permits the decoupling of fluid modes from drift modes. Isorrhopic equilibria are analyzed within the framework of geometrical optics resulting in (local) dispersion relations and ray constants. A general scheme is developed to evolve an arbitrary linear perturbation of a screwpinch equilibrium as an invertible integral transform (over the complete set of generalized eigenfunctions defined naturally by the equilibrium). Details of the structure of the function space and the associated spectra are elucidated. Features of the (global) dispersion relation owing to the presence of gyroelastic stabilization are revealed. An energy principle is developed to study the stability of the tubular screwpinch

  15. Thermophysical Properties of Fluids and Fluid Mixtures

    Energy Technology Data Exchange (ETDEWEB)

    Sengers, Jan V.; Anisimov, Mikhail A.

    2004-05-03

    The major goal of the project was to study the effect of critical fluctuations on the thermophysical properties and phase behavior of fluids and fluid mixtures. Long-range fluctuations appear because of the presence of critical phase transitions. A global theory of critical fluctuations was developed and applied to represent thermodynamic properties and transport properties of molecular fluids and fluid mixtures. In the second phase of the project, the theory was extended to deal with critical fluctuations in complex fluids such as polymer solutions and electrolyte solutions. The theoretical predictions have been confirmed by computer simulations and by light-scattering experiments. Fluctuations in fluids in nonequilibrium states have also been investigated.

  16. Automatic fluid dispenser

    Science.gov (United States)

    Sakellaris, P. C. (Inventor)

    1977-01-01

    Fluid automatically flows to individual dispensing units at predetermined times from a fluid supply and is available only for a predetermined interval of time after which an automatic control causes the fluid to drain from the individual dispensing units. Fluid deprivation continues until the beginning of a new cycle when the fluid is once again automatically made available at the individual dispensing units.

  17. Fluid Mechanics and Fluid Power (FMFP)

    Indian Academy of Sciences (India)

    Amitabh Bhattacharya

    decades, mainly due to the rapid improvement in computational efficiency, cameras, optics and instrumentation, both computational and experimental techniques have improved significantly, allowing researchers in Fluid Mechanics to build better mechanistic and analytical models for processes involving dynamics of fluids.

  18. Fluid Mechanics and Fluid Power (FMFP)

    Indian Academy of Sciences (India)

    Amitabh Bhattacharya

    of renewable energy (e.g., via wind, hydrokinetic generators), creating low-cost healthcare (e.g., via point-of-care medical testing) and improvement of energy efficiency of fluid power systems, depends on improving our understanding of Fluid. Mechanics. Fluids are ubiquitous in both nature and technological applications, ...

  19. Process fluid cooling system

    International Nuclear Information System (INIS)

    Farquhar, N.G.; Schwab, J.A.

    1977-01-01

    A system of heat exchangers is disclosed for cooling process fluids. The system is particularly applicable to cooling steam generator blowdown fluid in a nuclear plant prior to chemical purification of the fluid in which it minimizes the potential of boiling of the plant cooling water which cools the blowdown fluid

  20. Fluid mechanics in fluids at rest.

    Science.gov (United States)

    Brenner, Howard

    2012-07-01

    Using readily available experimental thermophoretic particle-velocity data it is shown, contrary to current teachings, that for the case of compressible flows independent dye- and particle-tracer velocity measurements of the local fluid velocity at a point in a flowing fluid do not generally result in the same fluid velocity measure. Rather, tracer-velocity equality holds only for incompressible flows. For compressible fluids, each type of tracer is shown to monitor a fundamentally different fluid velocity, with (i) a dye (or any other such molecular-tagging scheme) measuring the fluid's mass velocity v appearing in the continuity equation and (ii) a small, physicochemically and thermally inert, macroscopic (i.e., non-Brownian), solid particle measuring the fluid's volume velocity v(v). The term "compressibility" as used here includes not only pressure effects on density, but also temperature effects thereon. (For example, owing to a liquid's generally nonzero isobaric coefficient of thermal expansion, nonisothermal liquid flows are to be regarded as compressible despite the general perception of liquids as being incompressible.) Recognition of the fact that two independent fluid velocities, mass- and volume-based, are formally required to model continuum fluid behavior impacts on the foundations of contemporary (monovelocity) fluid mechanics. Included therein are the Navier-Stokes-Fourier equations, which are now seen to apply only to incompressible fluids (a fact well-known, empirically, to experimental gas kineticists). The findings of a difference in tracer velocities heralds the introduction into fluid mechanics of a general bipartite theory of fluid mechanics, bivelocity hydrodynamics [Brenner, Int. J. Eng. Sci. 54, 67 (2012)], differing from conventional hydrodynamics in situations entailing compressible flows and reducing to conventional hydrodynamics when the flow is incompressible, while being applicable to both liquids and gases.

  1. Videotapes and Movies on Fluid Dynamics and Fluid Machines

    OpenAIRE

    Carr, Bobbie; Young, Virginia E.

    1996-01-01

    Chapter 17 of Handbook of Fluid Dynamics and Fluid Machinery: Experimental and Computational Fluid Dynamics, Volume 11. A list of videorecordings and 16mm motion pictures about Fluid Dynamics and Fluid Machines.

  2. Fundamentals of Geophysical Fluid Dynamics

    Science.gov (United States)

    McWilliams, James C.

    2006-07-01

    Earth's atmosphere and oceans exhibit complex patterns of fluid motion over a vast range of space and time scales. These patterns combine to establish the climate in response to solar radiation that is inhomogeneously absorbed by the materials comprising air, water, and land. Spontaneous, energetic variability arises from instabilities in the planetary-scale circulations, appearing in many different forms such as waves, jets, vortices, boundary layers, and turbulence. Geophysical fluid dynamics (GFD) is the science of all these types of fluid motion. This textbook is a concise and accessible introduction to GFD for intermediate to advanced students of the physics, chemistry, and/or biology of Earth's fluid environment. The book was developed from the author's many years of teaching a first-year graduate course at the University of California, Los Angeles. Readers are expected to be familiar with physics and mathematics at the level of general dynamics (mechanics) and partial differential equations. Covers the essential GFD required for atmospheric science and oceanography courses Mathematically rigorous, concise coverage of basic theory and applications to both oceans and atmospheres Author is a world expert; this book is based on the course he has taught for many years Exercises are included, with solutions available to instructors from solutions@cambridge.org

  3. FOREWORD Fluid Mechanics and Fluid Power (FMFP)

    Indian Academy of Sciences (India)

    This section of the Special Issue carries selected articles from the Fluid Mechanics and Fluid. Power Conference held during 12–14 December 2013 at the National Institute of Technology,. Hamirpur (HP). The section includes three review articles and nine original research articles. These were selected on the basis of their ...

  4. Electric fluid pump

    Science.gov (United States)

    Van Dam, Jeremy Daniel; Turnquist, Norman Arnold; Raminosoa, Tsarafidy; Shah, Manoj Ramprasad; Shen, Xiaochun

    2015-09-29

    An electric machine is presented. The electric machine includes a hollow rotor; and a stator disposed within the hollow rotor, the stator defining a flow channel. The hollow rotor includes a first end portion defining a fluid inlet, a second end portion defining a fluid outlet; the fluid inlet, the fluid outlet, and the flow channel of the stator being configured to allow passage of a fluid from the fluid inlet to the fluid outlet via the flow channel; and wherein the hollow rotor is characterized by a largest cross-sectional area of hollow rotor, and wherein the flow channel is characterized by a smallest cross-sectional area of the flow channel, wherein the smallest cross-sectional area of the flow channel is at least about 25% of the largest cross-sectional area of the hollow rotor. An electric fluid pump and a power generation system are also presented.

  5. Hydraulic Brake Fluid,

    Science.gov (United States)

    A hydraulic brake fluid consisting of diethylene glycol , monoethyl ether of diethylene glycol , and castor oil has been improved as described in the patent by adding the fluid tributyl ether of orthophosphoric acid.

  6. Lectures on fluid mechanics

    CERN Document Server

    Shinbrot, Marvin

    2012-01-01

    Readable and user-friendly, this high-level introduction explores the derivation of the equations of fluid motion from statistical mechanics, classical theory, and a portion of the modern mathematical theory of viscous, incompressible fluids. 1973 edition.

  7. Pleural fluid Gram stain

    Science.gov (United States)

    Gram stain of pleural fluid ... mixing it with a violet stain (called a Gram stain). A laboratory specialist uses a microscope to ... reveals an abnormal collection of pleural fluid. The Gram stain can help identify the bacteria that might ...

  8. Computational Fluid Dynamics

    International Nuclear Information System (INIS)

    Myeong, Hyeon Guk

    1999-06-01

    This book deals with computational fluid dynamics with basic and history of numerical fluid dynamics, introduction of finite volume method using one-dimensional heat conduction equation, solution of two-dimensional heat conduction equation, solution of Navier-Stokes equation, fluid with heat transport, turbulent flow and turbulent model, Navier-Stokes solution by generalized coordinate system such as coordinate conversion, conversion of basic equation, program and example of calculation, application of abnormal problem and high speed solution of numerical fluid dynamics.

  9. Systems Biology

    Indian Academy of Sciences (India)

    IAS Admin

    Systems biology seeks to study biological systems as a whole, contrary to the reductionist approach that has dominated biology. Such a view of biological systems emanating from strong foundations of molecular level understanding of the individual components in terms of their form, function and interactions is promising to ...

  10. Fluid dynamic transient analysis

    International Nuclear Information System (INIS)

    Vilhena Reigosa, R. de

    1992-01-01

    This paper describes the methodology adopted at NUCLEN for the fluid dynamic analyses for ANGRA 2. The fluid dynamic analysis allows, through computer codes to simulate and quantify the loads resulting from fluid dynamic transients caused by postulated ruptures or operational transients, in the piping of the safety systems and of the important operational systems. (author)

  11. Amniotic fluid water dynamics

    NARCIS (Netherlands)

    Beall, M. H.; van den Wijngaard, J. P. H. M.; van Gemert, M. J. C.; Ross, M. G.

    2007-01-01

    Water arrives in the mammalian gestation from the maternal circulation across the placenta. It then circulates between the fetal water compartments, including the fetal body compartments, the placenta and the amniotic fluid. Amniotic fluid is created by the flow of fluid from the fetal lung and

  12. Fundamental Fluid Mechanics

    Indian Academy of Sciences (India)

    BOOK I REVIEW. Fundamental Fluid. Mechanics. Good Text Book Material. V H Arakeri. Fluid Mechanics for Engineers. P N Chatterjee. MacMillan India Limited. Vol. 1, pp. 367. RS.143. Vo1.2, pp.306. RS.130. Fluid Mechanics for Engineers in two vol- umes by P N Chatterjee contains standard material for a first level ...

  13. Scattering methods in complex fluids

    CERN Document Server

    Chen, Sow-Hsin

    2015-01-01

    Summarising recent research on the physics of complex liquids, this in-depth analysis examines the topic of complex liquids from a modern perspective, addressing experimental, computational and theoretical aspects of the field. Selecting only the most interesting contemporary developments in this rich field of research, the authors present multiple examples including aggregation, gel formation and glass transition, in systems undergoing percolation, at criticality, or in supercooled states. Connecting experiments and simulation with key theoretical principles, and covering numerous systems including micelles, micro-emulsions, biological systems, and cement pastes, this unique text is an invaluable resource for graduate students and researchers looking to explore and understand the expanding field of complex fluids.

  14. Complex fluids modeling and algorithms

    CERN Document Server

    Saramito, Pierre

    2016-01-01

    This book presents a comprehensive overview of the modeling of complex fluids, including many common substances, such as toothpaste, hair gel, mayonnaise, liquid foam, cement and blood, which cannot be described by Navier-Stokes equations. It also offers an up-to-date mathematical and numerical analysis of the corresponding equations, as well as several practical numerical algorithms and software solutions for the approximation of the solutions. It discusses industrial (molten plastics, forming process), geophysical (mud flows, volcanic lava, glaciers and snow avalanches), and biological (blood flows, tissues) modeling applications. This book is a valuable resource for undergraduate students and researchers in applied mathematics, mechanical engineering and physics.

  15. Computational fluid dynamics incompressible turbulent flows

    CERN Document Server

    Kajishima, Takeo

    2017-01-01

    This textbook presents numerical solution techniques for incompressible turbulent flows that occur in a variety of scientific and engineering settings including aerodynamics of ground-based vehicles and low-speed aircraft, fluid flows in energy systems, atmospheric flows, and biological flows. This book encompasses fluid mechanics, partial differential equations, numerical methods, and turbulence models, and emphasizes the foundation on how the governing partial differential equations for incompressible fluid flow can be solved numerically in an accurate and efficient manner. Extensive discussions on incompressible flow solvers and turbulence modeling are also offered. This text is an ideal instructional resource and reference for students, research scientists, and professional engineers interested in analyzing fluid flows using numerical simulations for fundamental research and industrial applications. • Introduces CFD techniques for incompressible flow and turbulence with a comprehensive approach; • Enr...

  16. Fluid and particle mechanics

    CERN Document Server

    Michell, S J

    2013-01-01

    Fluid and Particle Mechanics provides information pertinent to hydraulics or fluid mechanics. This book discusses the properties and behavior of liquids and gases in motion and at rest. Organized into nine chapters, this book begins with an overview of the science of fluid mechanics that is subdivided accordingly into two main branches, namely, fluid statics and fluid dynamics. This text then examines the flowmeter devices used for the measurement of flow of liquids and gases. Other chapters consider the principle of resistance in open channel flow, which is based on improper application of th

  17. Fluid inclusion geothermometry

    Science.gov (United States)

    Cunningham, C.G.

    1977-01-01

    Fluid inclusions trapped within crystals either during growth or at a later time provide many clues to the histories of rocks and ores. Estimates of fluid-inclusion homogenization temperature and density can be obtained using a petrographic microscope with thin sections, and they can be refined using heating and freezing stages. Fluid inclusion studies, used in conjunction with paragenetic studies, can provide direct data on the time and space variations of parameters such as temperature, pressure, density, and composition of fluids in geologic environments. Changes in these parameters directly affect the fugacity, composition, and pH of fluids, thus directly influencing localization of ore metals. ?? 1977 Ferdinand Enke Verlag Stuttgart.

  18. Swimming efficiency in a shear-thinning fluid

    OpenAIRE

    Nganguia, Herve; Pietrzyk, Kyle; Pak, On Shun

    2017-01-01

    Micro-organisms expend energy moving through complex media. While propulsion speed is an important property of locomotion, efficiency is another factor that may determine the swimming gait adopted by a micro-organism in order to locomote in an energetically favorable manner. The efficiency of swimming in a Newtonian fluid is well characterized for different biological and artificial swimmers. However, these swimmers often encounter biological fluids displaying shear-thinning viscosities. Litt...

  19. Spinning fluids reactor

    Science.gov (United States)

    Miller, Jan D; Hupka, Jan; Aranowski, Robert

    2012-11-20

    A spinning fluids reactor, includes a reactor body (24) having a circular cross-section and a fluid contactor screen (26) within the reactor body (24). The fluid contactor screen (26) having a plurality of apertures and a circular cross-section concentric with the reactor body (24) for a length thus forming an inner volume (28) bound by the fluid contactor screen (26) and an outer volume (30) bound by the reactor body (24) and the fluid contactor screen (26). A primary inlet (20) can be operatively connected to the reactor body (24) and can be configured to produce flow-through first spinning flow of a first fluid within the inner volume (28). A secondary inlet (22) can similarly be operatively connected to the reactor body (24) and can be configured to produce a second flow of a second fluid within the outer volume (30) which is optionally spinning.

  20. Intravenous fluids: balancing solutions.

    Science.gov (United States)

    Hoorn, Ewout J

    2017-08-01

    The topic of intravenous (IV) fluids may be regarded as "reverse nephrology", because nephrologists usually treat to remove fluids rather than to infuse them. However, because nephrology is deeply rooted in fluid, electrolyte, and acid-base balance, IV fluids belong in the realm of our specialty. The field of IV fluid therapy is in motion due to the increasing use of balanced crystalloids, partly fueled by the advent of new solutions. This review aims to capture these recent developments by critically evaluating the current evidence base. It will review both indications and complications of IV fluid therapy, including the characteristics of the currently available solutions. It will also cover the use of IV fluids in specific settings such as kidney transplantation and pediatrics. Finally, this review will address the pathogenesis of saline-induced hyperchloremic acidosis, its potential effect on outcomes, and the question if this should lead to a definitive switch to balanced solutions.

  1. Biological computation

    CERN Document Server

    Lamm, Ehud

    2011-01-01

    Introduction and Biological BackgroundBiological ComputationThe Influence of Biology on Mathematics-Historical ExamplesBiological IntroductionModels and Simulations Cellular Automata Biological BackgroundThe Game of Life General Definition of Cellular Automata One-Dimensional AutomataExamples of Cellular AutomataComparison with a Continuous Mathematical Model Computational UniversalitySelf-Replication Pseudo Code Evolutionary ComputationEvolutionary Biology and Evolutionary ComputationGenetic AlgorithmsExample ApplicationsAnalysis of the Behavior of Genetic AlgorithmsLamarckian Evolution Genet

  2. Microfluidic devices for biological applications

    CSIR Research Space (South Africa)

    Potgieter, S

    2010-01-01

    Full Text Available Microfluidics is a multi-disciplinary field that deals with the behaviour, control and manipulation of fluids constrained to sub-millilitre volumes. It is proving to be a useful tool for biological studies, affording advantages such as reduced cost...

  3. Fiber optic fluid detector

    Science.gov (United States)

    Angel, S. Michael

    1989-01-01

    Particular gases or liquids are detected with a fiber optic element (11, 11a to 11j) having a cladding or coating of a material (23, 23a to 23j) which absorbs the fluid or fluids and which exhibits a change of an optical property, such as index of refraction, light transmissiveness or fluoresence emission, for example, in response to absorption of the fluid. The fluid is sensed by directing light into the fiber optic element and detecting changes in the light, such as exit angle changes for example, that result from the changed optical property of the coating material. The fluid detector (24, 24a to 24j) may be used for such purposes as sensing toxic or explosive gases in the atmosphere, measuring ground water contamination or monitoring fluid flows in industrial processes, among other uses.

  4. Evolution of Biological Complexity

    Science.gov (United States)

    Goldstein, Raymond E.

    It is a general rule of nature that larger organisms are more complex, at least as measured by the number of distinct types of cells present. This reflects the fitness advantage conferred by a division of labor among specialized cells over homogeneous totipotency. Yet, increasing size has both costs and benefits, and the search for understanding the driving forces behind the evolution of multicellularity is becoming a very active area of research. This article presents an overview of recent experimental and theoretical work aimed at understanding this biological problem from the perspective of physics. For a class of model organisms, the Volvocine green algae, an emerging hypothesis connects the transition from organisms with totipotent cells to those with terminal germ-soma differentiation to the competition between diffusion and fluid advection created by beating flagella. A number of challenging problems in fluid dynamics, nonlinear dynamics, and control theory emerge when one probes the workings of the simplest multicellular organisms.

  5. Metalworking and machining fluids

    Science.gov (United States)

    Erdemir, Ali; Sykora, Frank; Dorbeck, Mark

    2010-10-12

    Improved boron-based metal working and machining fluids. Boric acid and boron-based additives that, when mixed with certain carrier fluids, such as water, cellulose and/or cellulose derivatives, polyhydric alcohol, polyalkylene glycol, polyvinyl alcohol, starch, dextrin, in solid and/or solvated forms result in improved metalworking and machining of metallic work pieces. Fluids manufactured with boric acid or boron-based additives effectively reduce friction, prevent galling and severe wear problems on cutting and forming tools.

  6. Electrorheological fluids and methods

    Science.gov (United States)

    Green, Peter F.; McIntyre, Ernest C.

    2015-06-02

    Electrorheological fluids and methods include changes in liquid-like materials that can flow like milk and subsequently form solid-like structures under applied electric fields; e.g., about 1 kV/mm. Such fluids can be used in various ways as smart suspensions, including uses in automotive, defense, and civil engineering applications. Electrorheological fluids and methods include one or more polar molecule substituted polyhedral silsesquioxanes (e.g., sulfonated polyhedral silsesquioxanes) and one or more oils (e.g., silicone oil), where the fluid can be subjected to an electric field.

  7. Plasmas and fluids

    International Nuclear Information System (INIS)

    Anon.

    1986-01-01

    Plasma and fluid physics includes the fields of fusion research and space investigation. This book discusses the most important advances in these areas over the past decade and recommends a stronger commitment to basic research in plasma and fluid physics. The book recommends that plasma and fluid physics be included in physics curriculums because of their increasing importance in energy and defense. The book also lists recent accomplishments in the fields of general plasma physics, fusion plasma confinement and heating, space and astrophysical plasmas, and fluid physics and lists research opportunities in these areas. A funding summary explains how research monies are allocated and suggests ways to improve their effectiveness

  8. The Fluids RAP

    Science.gov (United States)

    Nedyalkov, Ivaylo

    2016-11-01

    After fifteen years of experience in rap, and ten in fluid mechanics, "I am coming here with high-Reynolds-number stamina; I can beat these rap folks whose flows are... laminar." The rap relates fluid flows to rap flows. The fluid concepts presented in the song have varying complexity and the listeners/viewers will be encouraged to read the explanations on a site dedicated to the rap. The music video will provide an opportunity to share high-quality fluid visualizations with a general audience. This talk will present the rap lyrics, the vision for the video, and the strategy for outreach. Suggestions and comments will be welcomed.

  9. Fluid dynamics transactions

    CERN Document Server

    Fiszdon, W

    1965-01-01

    Fluid Dynamics Transactions, Volume 2 compiles 46 papers on fluid dynamics, a subdiscipline of fluid mechanics that deals with fluid flow. The topics discussed in this book include developments in interference theory for aeronautical applications; diffusion from sources in a turbulent boundary layer; unsteady motion of a finite wing span in a compressible medium; and wall pressure covariance and comparison with experiment. The certain classes of non-stationary axially symmetric flows in magneto-gas-dynamics; description of the phenomenon of secondary flows in curved channels by means of co

  10. Theoretical Fluid Dynamics

    CERN Document Server

    Shivamoggi, Bhimsen K

    1998-01-01

    "Although there are many texts and monographs on fluid dynamics, I do not know of any which is as comprehensive as the present book. It surveys nearly the entire field of classical fluid dynamics in an advanced, compact, and clear manner, and discusses the various conceptual and analytical models of fluid flow." - Foundations of Physics on the first edition. Theoretical Fluid Dynamics functions equally well as a graduate-level text and a professional reference. Steering a middle course between the empiricism of engineering and the abstractions of pure mathematics, the author focuses

  11. Is swimming in a shear-thinning fluid more efficient?

    Science.gov (United States)

    Pietrzyk, Kyle; Nganguia, Herve; Pak, On Shun

    2017-11-01

    Micro-organisms expend energy moving through complex fluids that often display shear-thinning viscosity. A motility mechanism not only needs to generate the necessary propulsion speed but also be energetically efficient. Although the efficiency of swimming is well characterized in Newtonian fluids, much less is known about this biologically relevant aspect of locomotion in shear-thinning fluids. Does the shear-thinning rheology render swimming more efficient or less? How does it alter the efficiency of different types of swimmers? We will address these fundamental questions of locomotion in a shear-thinning fluid.

  12. Intracellular Fluid Mechanics: Coupling Cytoplasmic Flow with Active Cytoskeletal Gel

    Science.gov (United States)

    Mogilner, Alex; Manhart, Angelika

    2018-01-01

    The cell is a mechanical machine, and continuum mechanics of the fluid cytoplasm and the viscoelastic deforming cytoskeleton play key roles in cell physiology. We review mathematical models of intracellular fluid mechanics, from cytoplasmic fluid flows, to the flow of a viscous active cytoskeletal gel, to models of two-phase poroviscous flows, to poroelastic models. We discuss application of these models to cell biological phenomena, such as organelle positioning, blebbing, and cell motility. We also discuss challenges of understanding fluid mechanics on the cellular scale.

  13. Fluid Dynamics of the Heart and its Valves

    Science.gov (United States)

    Peskin, Charles S.

    1997-11-01

    The fluid dynamics of the heart involve the interaction of blood, a viscous incompressible fluid, with the flexible, elastic, fiber-reinforced heart valve leaflets that are immersed in that fluid. Neither the fluid motion nor the valve leaflet motion are known in advance: both must be computed simultaneously by solving their coupled equations of motion. This can be done by the immersed boundary method(Peskin CS and McQueen DM: A general method for the computer simulation of biological systems interacting with fluids. In: Biological Fluid Dynamics (Ellington CP and Pedley TJ, eds.), The Company of Biologists Limited, Cambridge UK, 1995, pp. 265-276.), which can be extended to incorporate the contractile fiber architecture of the muscular heart walls as well as the valve leaflets and the blood. In this way we arrive at a three-dimensional computer model of the heart(Peskin CS and McQueen DM: Fluid dynamics of the heart and its valves. In: Case Studies in Mathematical Modeling: Ecology, Physiology, and Cell Biology (Othmer HG, Adler FR, Lewis MA, and Dallon JC, eds.), Prentice-Hall, Englewood Cliffs NJ, 1996, pp. 309-337.), which can be used as a test chamber for the design of prosthetic cardiac valves, and also to study the function of the heart in health and in disease. Numerical solutions of the equations of cardiac fluid dynamics obtained by the immersed boundary method will be presented in the form of a video animation of the beating heart.

  14. Comparison of dispersive liquid-liquid microextraction and hollow fiber liquid-liquid-liquid microextraction for the determination of fentanyl, alfentanil, and sufentanil in water and biological fluids by high-performance liquid chromatography.

    Science.gov (United States)

    Saraji, Mohammad; Khalili Boroujeni, Malihe; Hajialiakbari Bidgoli, Ali Akbar

    2011-06-01

    Dispersive liquid-liquid microextraction (DLLME) and hollow fiber liquid-liquid-liquid microextraction (HF-LLLME) combined with HPLC-DAD have been applied for the determination of three narcotic drugs (alfentanil, fentanyl, and sufentanil) in biological samples (human plasma and urine). Different DLLME parameters influencing the extraction efficiency such as type and volume of the extraction solvent and the disperser solvent, concentration of NaOH, and salt addition were investigated. In the HF-LLLME, the effects of important parameters including organic solvent type, concentration of NaOH as donor solution, concentration of H(2)SO(4) as acceptor phase, salt addition, stirring rate, temperature, and extraction time were investigated and optimized. The results showed that both extraction methods exhibited good linearity, precision, enrichment factor, and detection limit. Under optimal condition, the limits of detection ranged from 0.4 to 1.9 μg/L and from 1.1 to 2.3 μg/L for DLLME and HF-LLLME, respectively. For DLLME, the intra- and inter-day precisions were 1.7-6.4% and 14.2-15.9%, respectively; and for HF-LLLME were 0.7-5.2% and 3.3-10.1%, respectively. The enrichment factors were from 275 to 325 and 190 to 237 for DLLME and HF-LLLME, respectively. The applicability of the proposed methods was investigated by analyzing biological samples. For analysis of human plasma and urine samples, HF-LLLME showed higher precision, more effective sample clean-up, higher extraction efficiency, lower organic solvent consumption than DLLME.

  15. Complexity in fluids

    International Nuclear Information System (INIS)

    Bayly, B.

    1991-01-01

    Fluids are basically very simple things. The fluids encountered all the time - air, water, milk, coffee, etc. - are undramatic. One blob of a given fluid looks much like any other, except for such gross properties as volume or mass. Of course, blobs of fluid come in different shapes. However, it's easy to change the shape of a blob of fluid, with the result that we rarely think of the shape of a fluid blob as a defining property. In fact, a blob that starts with one shape can be deformed into almost any other shape, with arbitrarily small input of energy. When one talks about lumps of a solid, in contrast, shape is important. This is because it takes work, i.e., energy, to change the shape of a solid. Making a small deformation from some rest configuration takes a small amount of energy, and a large deformation takes a lot of energy. Sometimes, as in idealized elastic systems, the required energy goes to infinity as the deformation becomes unbounded. Real solids usually break if you deform them enough; all subsequent deformations cost no energy. Basically, a finite deformation requires finite energy. Complexity arises in fluid systems because the shape of a blob of fluid is indeterminate. Nothing prevents an initially simple fluid blob from deforming into the weirdest shape imaginable. It is the absence of any kind of blob-shape constraint that allows complexity to enter fluid science. During these lectures the author briefly describes a few areas in which complexity arises and has to be dealt with. These lectures will be roughly divided as follows: (1) physical and mathematical description of fluids and flows; (2) flow transport and ergodic theory; (3) magnetic dynamos and related problems; (4) flow instabilities; (5) turbulence

  16. Fluid loading responsiveness

    NARCIS (Netherlands)

    Geerts, Bart

    2011-01-01

    Patients in the intensive care unit (ICU) and in the peri-operative phase are dependent on physicians and nurses for their fluid intake. Volume status optimization is required to maximize oxygen delivery to vital organs. Unnecessary fluid administration can, however, lead to general and pulmonary

  17. Fluid Statics and Archimedes

    Indian Academy of Sciences (India)

    stationary fluid only normal stress (pressure) is present and tangential stresses are absent. In this article we ... delayed the discovery of the principle by a few centuries! Archimedes formulated his laws on buoyancy ... stress in the study of mechanics of solids and fluids (see Boxl). Just as temperature and density, stress can ...

  18. Applications of fluid dynamics

    International Nuclear Information System (INIS)

    Round, G.R.; Garg, V.K.

    1986-01-01

    This book describes flexible and practical approach to learning the basics of fluid dynamics. Each chapter is a self-contained work session and includes a fluid dynamics concept, an explanation of the principles involved, an illustration of their application and references on where more detailed discussions can be found

  19. Tumor interstitial fluid

    DEFF Research Database (Denmark)

    Gromov, Pavel; Gromova, Irina; Olsen, Charlotta J.

    2013-01-01

    Tumor interstitial fluid (TIF) is a proximal fluid that, in addition to the set of blood soluble phase-borne proteins, holds a subset of aberrantly externalized components, mainly proteins, released by tumor cells and tumor microenvironment through various mechanisms, which include classical secr...

  20. Peritoneal fluid culture

    Science.gov (United States)

    Culture - peritoneal fluid ... sent to the laboratory for Gram stain and culture. The sample is checked to see if bacteria ... The peritoneal fluid culture may be negative, even if you have ... diagnosis of peritonitis is based on other factors, in addition ...

  1. Time Independent Fluids

    Science.gov (United States)

    Collyer, A. A.

    1973-01-01

    Discusses theories underlying Newtonian and non-Newtonian fluids by explaining flow curves exhibited by plastic, shear-thining, and shear-thickening fluids and Bingham plastic materials. Indicates that the exact mechanism governing shear-thickening behaviors is a problem of further study. (CC)

  2. Flagellar swimming in viscoelastic fluids: role of fluid elastic stress revealed by simulations based on experimental data.

    Science.gov (United States)

    Li, Chuanbin; Qin, Boyang; Gopinath, Arvind; Arratia, Paulo E; Thomases, Becca; Guy, Robert D

    2017-10-01

    Many important biological functions depend on microorganisms' ability to move in viscoelastic fluids such as mucus and wet soil. The effects of fluid elasticity on motility remain poorly understood, partly because the swimmer strokes depend on the properties of the fluid medium, which obfuscates the mechanisms responsible for observed behavioural changes. In this study, we use experimental data on the gaits of Chlamydomonas reinhardtii swimming in Newtonian and viscoelastic fluids as inputs to numerical simulations that decouple the swimmer gait and fluid type in order to isolate the effect of fluid elasticity on swimming. In viscoelastic fluids, cells employing the Newtonian gait swim faster but generate larger stresses and use more power, and as a result the viscoelastic gait is more efficient. Furthermore, we show that fundamental principles of swimming based on viscous fluid theory miss important flow dynamics: fluid elasticity provides an elastic memory effect that increases both the forward and backward speeds, and (unlike purely viscous fluids) larger fluid stress accumulates around flagella moving tangent to the swimming direction, compared with the normal direction. © 2017 The Author(s).

  3. Relativistic thermodynamics of fluids

    International Nuclear Information System (INIS)

    Souriau, J.-M.

    1977-05-01

    The relativistic covariant definition of a statistical equilibrium, applied to a perfect gas, involves a 'temperature four-vector', whose direction is the mean velocity of the fluid, and whose length is the reciprocal temperature. The hypothesis of this 'temperature four-vector' being a relevant variable for the description of the dissipative motions of a simple fluid is discussed. The kinematics is defined by using a vector field and measuring the number of molecules. Such a dissipative fluid is subject to motions involving null entropy generation; the 'temperature four-vector' is then a Killing vector; the equations of motion can be completely integrated. Perfect fluids can be studied by this way and the classical results of Lichnerowicz are obtained. In weakly dissipative motions two viscosity coefficient appear together with the heat conductibility coefficient. Two other coefficients perharps measurable on real fluids. Phase transitions and shock waves are described with using the model [fr

  4. GC-MS determination of creatinine in human biological fluids as pentafluorobenzyl derivative in clinical studies and biomonitoring: Inter-laboratory comparison in urine with Jaffé, HPLC and enzymatic assays.

    Science.gov (United States)

    Tsikas, Dimitrios; Wolf, Alexander; Mitschke, Anja; Gutzki, Frank-Mathias; Will, Wolfgang; Bader, Michael

    2010-10-01

    In consideration of its relatively constant urinary excretion rate, creatinine in urine is a useful biochemical parameter to correct the urinary excretion rate of endogenous and exogenous biomolecules. Assays based on the reaction of creatinine and picric acid first reported by Jaffé in 1886 still belong to the most frequently used laboratory approaches for creatinine measurement in urine. Further analytical methods for creatinine include HPLC-UV, GC-MS, and LC-MS and LC-MS/MS approaches. In the present article we report on the development, validation and biomedical application of a new GC-MS method for the reliable quantitative determination of creatinine in human urine, plasma and serum. This method is based on the derivatization of creatinine (d(0)-Crea) and the internal standard [methyl-trideutero]creatinine (d(3)-Crea) with pentafluorobenzyl (PFB) bromide in the biological sample directly or after dilution with phosphate buffered saline, extraction of the reaction products with toluene and quantification in 1-μl aliquots of the toluene extract by selected-ion monitoring of m/z 112 for d(0)-Crea-PFB and m/z 115 for d(3)-Crea-PFB in the electron-capture negative-ion chemical ionization mode. The limit of detection of the method is 100 amol of creatinine. In an inter-laboratory study on urine samples from 100 healthy subjects, the GC-MS method was used to test the reliability of currently used Jaffé, enzymatic and HPLC assays in clinical and occupational studies. The results of the inter-laboratory study indicate that all three tested methods allow for satisfactory quantification of creatinine in human urine. The GC-MS method is suitable for use as a reference method for urinary creatinine in humans. In serum, creatine was found to contribute to creatinine up to 20% when measured by the present GC-MS method. The application of the GC-MS method can be extended to other biological samples such as saliva. Copyright © 2010 Elsevier B.V. All rights reserved.

  5. Slip in quantum fluids

    International Nuclear Information System (INIS)

    Einzel, D.; Parpia, J.M.

    1997-01-01

    In this review the authors describe theoretical and experimental investigations of general slip phenomena in context with the flow of the quantum liquids 3 He, 4 He and their mixtures at low temperatures. The phenomena of slip is related to a boundary effect. It occurs when sufficiently dilute gases flow along the wall of an experimental cell. A fluid is said to exhibit slip when the fluid velocity at the wall is not equal to the wall's velocity. Such a situation occurs whenever the wall reflects the fluid particles in a specular-like manner, and/or if the fluid is describable in terms of a dilute ordinary gas (classical fluid) or a dilute gas of thermal excitations (quantum fluid). The slip effect in quantum fluids is discussed theoretically on the basis of generalized Landau-Boltzmann transport equations and generalized to apply to a regime of ballistic motion of the quasiparticles in the fluid. The central result is that the transport coefficient of bulk shear viscosity, which typically enters in the Poiseuille flow resistance and the transverse acoustic impedance, has to be replaced by geometry dependent effective viscosity, which depends on the details of the interaction of the fluid particles with the cell walls. The theoretical results are compared with various experimental data obtained in different geometries and for both Bose and Fermi quantum fluids. Good agreement between experiment and theory is found particularly in the case of pure normal and superfluid 3 He, with discrepancies probably arising because of deficiencies in characterization of the experimental surfaces

  6. Systems Biology

    Energy Technology Data Exchange (ETDEWEB)

    Wiley, H S.

    2006-06-01

    The biology revolution over the last 50 years has been driven by the ascendancy of molecular biology. This was enthusiastically embraced by most biologists because it took us into increasingly familiar territory. It took mysterious processes, such as the replication of genetic material and assigned them parts that could be readily understood by the human mind. When we think of ''molecular machines'' as being the underlying basis of life, we are using a paradigm derived from everyday experience. However, the price that we paid was a relentless drive towards reductionism and the attendant balkanization of biology. Now along comes ''systems biology'' that promises us a solution to the problem of ''knowing more and more about less and less''. Unlike molecular biology, systems biology appears to be taking us into unfamiliar intellectual territory, such as statistics, mathematics and computer modeling. Not surprisingly, systems biology has met with widespread skepticism and resistance. Why do we need systems biology anyway and how does this new area of research promise to change the face of biology in the next couple of decades?

  7. Biological therapeutics

    National Research Council Canada - National Science Library

    Greenstein, Ben; Brook, Daniel A

    2011-01-01

    This introductory textbook covers all the main categories of biological medicines, including vaccines, hormonal preparations, drugs for rheumatoid arthritis and other connective tissue diseases, drugs...

  8. The development of radioimmunoassay for somatostatin, its use in the measurement of this peptide in tissues and biological fluids, and an assessment of its physiological role in health and disease

    International Nuclear Information System (INIS)

    Pimstone, B.; Sheppard, M.

    1979-06-01

    Somatostatin peptide initially isolated from ovine hypothalamus has inhibitory effect on secretion growth hormone and on other pituitary hormones like TSH, ACTH. The assay sensitivity sensitivity was approximately 6 pg/tube. The authors did not observe any significant crossreactivity with 19 different hormones and biological substances. High concentration of somatostatin was found in central nervous system, but not only in median eminence of hypothalamus but also in other areas including spine cord. High level of somatostatin was also observed in pancreas, gastric antrum and distal colon. The determinations of somatostatin-like in sera of 22 men and 26 women allowed to establish the normal values which are 0.274+-0.009 ng/ml. MCR in normal subjects was 1949+-250 ml/min, in cases with chronic liver disease the values were similar, and in subjects with chronic renal failure highly significant lowering of MCR equal 501+-32.7 ml/min was observed. Tsub(1/2) varied from 1.1 to 3.0 min in normal subjects, in patients with liver diseases was in ranges 1.2 - 4.8 min and in chronic renal failure from 2.6 - 4.9 min

  9. Manipulation of microfluidic droplets by electrorheological fluid

    KAUST Repository

    Zhang, Menying

    2009-09-01

    Microfluidics, especially droplet microfluidics, attracts more and more researchers from diverse fields, because it requires fewer materials and less time, produces less waste and has the potential of highly integrated and computer-controlled reaction processes for chemistry and biology. Electrorheological fluid, especially giant electrorheological fluid (GERF), which is considered as a kind of smart material, has been applied to the microfluidic systems to achieve active and precise control of fluid by electrical signal. In this review article, we will introduce recent results of microfluidic droplet manipulation, GERF and some pertinent achievements by introducing GERF into microfluidic system: digital generation, manipulation of "smart droplets" and droplet manipulation by GERF. Once it is combined with real-time detection, integrated chip with multiple functions can be realized. © 2009 Wiley-VCH Verlag GmbH & Co. KGaA.

  10. Is synthetic biology mechanical biology?

    Science.gov (United States)

    Holm, Sune

    2015-12-01

    A widespread and influential characterization of synthetic biology emphasizes that synthetic biology is the application of engineering principles to living systems. Furthermore, there is a strong tendency to express the engineering approach to organisms in terms of what seems to be an ontological claim: organisms are machines. In the paper I investigate the ontological and heuristic significance of the machine analogy in synthetic biology. I argue that the use of the machine analogy and the aim of producing rationally designed organisms does not necessarily imply a commitment to mechanical biology. The ideal of applying engineering principles to biology is best understood as expressing recognition of the machine-unlikeness of natural organisms and the limits of human cognition. The paper suggests an interpretation of the identification of organisms with machines in synthetic biology according to which it expresses a strategy for representing, understanding, and constructing living systems that are more machine-like than natural organisms.

  11. Liposomes as potential masking agents in sport doping. Part 1: analysis of phospholipids and sphingomyelins in drugs and biological fluids by aqueous normal-phase liquid chromatography-tandem mass spectrometry.

    Science.gov (United States)

    Esposito, Simone; Colicchia, Sonia; de la Torre, Xavier; Mazzarino, Monica; Botrè, Francesco

    2017-01-01

    In the present work, aqueous normal-phase liquid chromatography coupled to tandem mass spectrometry (LC-MS/MS), in different acquisition modes, was employed for the direct analysis and profiling of nine phospholipid classes (phosphatidic acids, phosphatidylserines, phosphatidylethanolamines, lysophosphatidylethanolamines, phosphatidylglycerols, phosphatidylinositols, phosphatidylcholines, lysophosphatidylcholines, and sphingomyelins) in biological and pharmaceutical matrices. After chromatographic separation by a diol column, detection and elucidation of phospholipid and sphingomyelin classes and molecular species were performed by different scan acquisition modes. For screening analysis, molecular ions [M + H] + were detected in positive precursor ion scan of m/z 184 for the classes of phosphatidylcholines, lyso-phosphatidylcholines and sphingomyelins; while phosphatidylethanolamines and lyso-phosphatidylethanolamines were detected monitoring neutral loss scan of 141 Da; and phosphatidylserines detected using neutral loss scan of 184 Da. Molecular ions [M-H] - were instead acquired in negative precursor ion scan of m/z 153 for the classes of phosphatidic acids and phosphatidylglycerols; and of m/z 241 for the phosphatidylinositols. For the identification of the single molecular species, product ion scan mass spectra of the [M + HCOO] - ions for phosphatidylcholines and [M + H] + ions for the other phospholipids considered were determined for each class and compared with the fragmentation pattern of model phospholipid reference standard. By this approach, nearly 100 phospholipids and sphingomyelins were detected and identified. The optimized method was then used to characterize the phospholipid and sphingomyelin profiles in human plasma and urine samples and in two phospholipid-based pharmaceutical formulations, proving that it also allows to discriminate compounds of endogenous origin from those resulting from the intake of pharmaceutical products

  12. Absorption fluids data survey

    Science.gov (United States)

    Macriss, R. A.; Zawacki, T. S.

    Development of improved data for the thermodynamic, transport and physical properties of absorption fluids were studied. A specific objective of this phase of the study is to compile, catalog and coarse screen the available US data of known absorption fluid systems and publish it as a first edition document to be distributed to manufacturers, researchers and others active in absorption heat pump activities. The methodology and findings of the compilation, cataloguing and coarse screening of the available US data on absorption fluid properties and presents current status and future work on this project are summarized. Both in house file and literature searches were undertaken to obtain available US publications with pertinent physical, thermodynamic and transport properties data for absorption fluids. Cross checks of literature searches were also made, using available published bibliographies and literature review articles, to eliminate secondary sources for the data and include only original sources and manuscripts. The properties of these fluids relate to the liquid and/or vapor state, as encountered in normal operation of absorption equipment employing such fluids, and to the crystallization boundary of the liquid phase, where applicable. The actual data were systematically classified according to the type of fluid and property, as well as temperature, pressure and concentration ranges over which data were available. Data were sought for 14 different properties: Vapor-Liquid Equilibria, Crystallization Temperature, Corrosion Characteristics, Heat of Mixing, Liquid-Phase-Densities, Vapor-Liquid-Phase Enthalpies, Specific Heat, Stability, Viscosity, Mass Transfer Rate, Heat Transfer Rate, Thermal Conductivity, Flammability, and Toxicity.

  13. FRACTURING FLUID CHARACTERIZATION FACILITY

    Energy Technology Data Exchange (ETDEWEB)

    Subhash Shah

    2000-08-01

    Hydraulic fracturing technology has been successfully applied for well stimulation of low and high permeability reservoirs for numerous years. Treatment optimization and improved economics have always been the key to the success and it is more so when the reservoirs under consideration are marginal. Fluids are widely used for the stimulation of wells. The Fracturing Fluid Characterization Facility (FFCF) has been established to provide the accurate prediction of the behavior of complex fracturing fluids under downhole conditions. The primary focus of the facility is to provide valuable insight into the various mechanisms that govern the flow of fracturing fluids and slurries through hydraulically created fractures. During the time between September 30, 1992, and March 31, 2000, the research efforts were devoted to the areas of fluid rheology, proppant transport, proppant flowback, dynamic fluid loss, perforation pressure losses, and frictional pressure losses. In this regard, a unique above-the-ground fracture simulator was designed and constructed at the FFCF, labeled ''The High Pressure Simulator'' (HPS). The FFCF is now available to industry for characterizing and understanding the behavior of complex fluid systems. To better reflect and encompass the broad spectrum of the petroleum industry, the FFCF now operates under a new name of ''The Well Construction Technology Center'' (WCTC). This report documents the summary of the activities performed during 1992-2000 at the FFCF.

  14. Materials for ER Fluids

    Science.gov (United States)

    Bloodworth, Robert; Wendt, Eckhard

    Recent improvements in the physical understanding of ER fluids have led to the rational design of new ER materials with improved properties. This paper gives an overview of several recent developments in the formulation of ER fluids, concentrating on new particulate phases for ER dispersions. Examples of homogeneous ER fluids are also discussed. The trend leading to designed ER dispersions is demonstrated by a new class of electrorheological fluids based on non-aqueous polyurethane dispersions. The fluids exhibit an attractive combination of properties: low viscosity, high ER effect, and low conductivity. The dispersed phase consists of a specially developed polyurethane elastomer which solvates and stabilizes metal salts. The polymer network density influences the mobility of the dissolved ions, allowing a surprising degree of control over the ER effect. Properties such as the field strength dependence of the ER-effect, switching response, and conductivity of these fluids correlate directly with changes in the polymer structure. Electrorheological measurements in a couette viscometer (shear-mode) and in a model shock absorber (flow-mode) using a commercial polyurethane-based fluid show that the ER effect is also dependent upon the shearing geometry.

  15. Mesoscopic biology

    Indian Academy of Sciences (India)

    Abstract. In this paper we present a qualitative outlook of mesoscopic biology where the typical length scale is of the order of nanometers and the energy scales comparable to thermal energy. ... National Center for Biological Sciences, Tata Institute of Fundamental Research, UAS-GKVK Campus, Bangalore 560 065, India ...

  16. Computational biology

    DEFF Research Database (Denmark)

    Hartmann, Lars Røeboe; Jones, Neil; Simonsen, Jakob Grue

    2011-01-01

    Computation via biological devices has been the subject of close scrutiny since von Neumann’s early work some 60 years ago. In spite of the many relevant works in this field, the notion of programming biological devices seems to be, at best, ill-defined. While many devices are claimed or proved t...

  17. Mesoscopic biology

    Indian Academy of Sciences (India)

    In this paper we present a qualitative outlook of mesoscopic biology where the typical length scale is of the order of nanometers and the energy scales comparable to thermal energy. Novel biomolecular machines, governed by coded information at the level of DNA and proteins, operate at these length scales in biological ...

  18. Cerebral spinal fluid (CSF) collection

    Science.gov (United States)

    ... ency/article/003428.htm Cerebral spinal fluid (CSF) collection To use the sharing features on this page, please enable JavaScript. Cerebrospinal fluid (CSF) collection is a test to look at the fluid ...

  19. Fluid movement and creativity.

    Science.gov (United States)

    Slepian, Michael L; Ambady, Nalini

    2012-11-01

    Cognitive scientists describe creativity as fluid thought. Drawing from findings on gesture and embodied cognition, we hypothesized that the physical experience of fluidity, relative to nonfluidity, would lead to more fluid, creative thought. Across 3 experiments, fluid arm movement led to enhanced creativity in 3 domains: creative generation, cognitive flexibility, and remote associations. Alternative mechanisms such as enhanced mood and motivation were also examined. These results suggest that creativity can be influenced by certain types of physical movement. (PsycINFO Database Record (c) 2012 APA, all rights reserved).

  20. Fundamentals of fluid lubrication

    Science.gov (United States)

    Hamrock, Bernard J.

    1991-01-01

    The aim is to coordinate the topics of design, engineering dynamics, and fluid dynamics in order to aid researchers in the area of fluid film lubrication. The lubrication principles that are covered can serve as a basis for the engineering design of machine elements. The fundamentals of fluid film lubrication are presented clearly so that students that use the book will have confidence in their ability to apply these principles to a wide range of lubrication situations. Some guidance on applying these fundamentals to the solution of engineering problems is also provided.

  1. Synthetic Base Fluids

    Science.gov (United States)

    Brown, M.; Fotheringham, J. D.; Hoyes, T. J.; Mortier, R. M.; Orszulik, S. T.; Randles, S. J.; Stroud, P. M.

    The chemical nature and technology of the main synthetic lubricant base fluids is described, covering polyalphaolefins, alkylated aromatics, gas-to-liquid (GTL) base fluids, polybutenes, aliphatic diesters, polyolesters, polyalkylene glycols or PAGs and phosphate esters.Other synthetic lubricant base oils such as the silicones, borate esters, perfluoroethers and polyphenylene ethers are considered to have restricted applications due to either high cost or performance limitations and are not considered here.Each of the main synthetic base fluids is described for their chemical and physical properties, manufacture and production, their chemistry, key properties, applications and their implications when used in the environment.

  2. The forward undulatory locomotion of Ceanorhabditis elegans in viscoelastic fluids

    Science.gov (United States)

    Shen, Amy; Ulrich, Xialing

    2013-11-01

    Caenorhabditis elegans is a soil dwelling roundworm that has served as model organisms for studying a multitude of biological and engineering phenomena. We study the undulatory locomotion of nematode in viscoelastic fluids with zero-shear viscosity varying from 0.03-75 Pa .s and relaxation times ranging from 0-350 s. We observe that the averaged normalized wavelength of swimming worm is essentially the same as that in Newtonian fluids. The undulatory frequency f shows the same reduction rate with respect to zero-shear viscosity in viscoelastic fluids as that found in the Newtonian fluids, meaning that the undulatory frequency is mainly controlled by the fluid viscosity. However, the moving speed Vm of the worm shows more distinct dependence on the elasticity of the fluid and exhibits a 4% drop with each 10-fold increase of the Deborah number De, a dimensionless number characterizing the elasticity of a fluid. To estimate the swimming efficiency coefficient and the ratio K =CN /CL of resistive coefficients of the worm in various viscoelastic fluids, we show that whereas it would take the worm around 7 periods to move a body length in a Newtonian fluid, it would take 27 periods to move a body length in a highly viscoelastic fluid.

  3. The Maze of the Cerebrospinal Fluid Discovery

    Directory of Open Access Journals (Sweden)

    Leszek Herbowski

    2013-01-01

    Full Text Available The author analyzes a historical, long, and tortuous way to discover the cerebrospinal fluid. At least 35 physicians and anatomists described in the text have laid the fundamentals of recognition of this biological fluid’s presence. On the basis of crucial anatomical, experimental, and clinical works there are four greatest physicians who should be considered as equal cerebrospinal fluid’s discoverers: Egyptian Imhotep, Venetian Nicolo Massa, Italian Domenico Felice Cotugno, and French François Magendie.

  4. The Maze of the Cerebrospinal Fluid Discovery

    OpenAIRE

    Herbowski, Leszek

    2013-01-01

    The author analyzes a historical, long, and tortuous way to discover the cerebrospinal fluid. At least 35 physicians and anatomists described in the text have laid the fundamentals of recognition of this biological fluid’s presence. On the basis of crucial anatomical, experimental, and clinical works there are four greatest physicians who should be considered as equal cerebrospinal fluid’s discoverers: Egyptian Imhotep, Venetian Nicolo Massa, Italian Domenico Felice Cotugno, and French Franço...

  5. Quantum Biology

    Directory of Open Access Journals (Sweden)

    Alessandro Sergi

    2009-06-01

    Full Text Available A critical assessment of the recent developmentsof molecular biology is presented.The thesis that they do not lead to a conceptualunderstanding of life and biological systems is defended.Maturana and Varela's concept of autopoiesis is briefly sketchedand its logical circularity avoided by postulatingthe existence of underlying living processes,entailing amplification from the microscopic to the macroscopic scale,with increasing complexity in the passage from one scale to the other.Following such a line of thought, the currently accepted model of condensed matter, which is based on electrostatics and short-ranged forces,is criticized. It is suggested that the correct interpretationof quantum dispersion forces (van der Waals, hydrogen bonding, and so onas quantum coherence effects hints at the necessity of includinglong-ranged forces (or mechanisms for them incondensed matter theories of biological processes.Some quantum effects in biology are reviewedand quantum mechanics is acknowledged as conceptually important to biology since withoutit most (if not all of the biological structuresand signalling processes would not even exist. Moreover, it is suggested that long-rangequantum coherent dynamics, including electron polarization,may be invoked to explain signal amplificationprocess in biological systems in general.

  6. Biological Oceanography

    Science.gov (United States)

    Dyhrman, Sonya

    2004-10-01

    The ocean is arguably the largest habitat on the planet, and it houses an astounding array of life, from microbes to whales. As a testament to this diversity and its importance, the discipline of biological oceanography spans studies of all levels of biological organization, from that of single genes, to organisms, to their population dynamics. Biological oceanography also includes studies on how organisms interact with, and contribute to, essential global processes. Students of biological oceanography are often as comfortable looking at satellite images as they are electron micrographs. This diversity of perspective begins the textbook Biological Oceanography, with cover graphics including a Coastal Zone Color Scanner image representing chlorophyll concentration, an electron micrograph of a dinoflagellate, and a photograph of a copepod. These images instantly capture the reader's attention and illustrate some of the different scales on which budding oceanographers are required to think. Having taught a core graduate course in biological oceanography for many years, Charlie Miller has used his lecture notes as the genesis for this book. The text covers the subject of biological oceanography in a manner that is targeted to introductory graduate students, but it would also be appropriate for advanced undergraduates.

  7. Pericardial fluid culture

    Science.gov (United States)

    ... to identify organisms that cause infection. Pericardial fluid gram stain is a related topic. How the Test is ... member of Hi-Ethics and subscribes to the principles of the Health on the Net Foundation (www. ...

  8. Polymer Fluid Dynamics.

    Science.gov (United States)

    Bird, R. Byron

    1980-01-01

    Problems in polymer fluid dynamics are described, including development of constitutive equations, rheometry, kinetic theory, flow visualization, heat transfer studies, flows with phase change, two-phase flow, polymer unit operations, and drag reduction. (JN)

  9. Modeling Fluid Structure Interaction

    National Research Council Canada - National Science Library

    Benaroya, Haym

    2000-01-01

    The principal goal of this program is on integrating experiments with analytical modeling to develop physics-based reduced-order analytical models of nonlinear fluid-structure interactions in articulated naval platforms...

  10. Windshield washer fluid

    Science.gov (United States)

    ... fluid is a brightly colored liquid made of methanol, a poisonous alcohol. Sometimes, small amounts of other toxic alcohols, such as ethylene glycol, are added to the mixture. Some young children ...

  11. Amniotic fluid inflammatory cytokines

    DEFF Research Database (Denmark)

    Abdallah, Morsi; Larsen, Nanna; Grove, Jakob

    2013-01-01

    The aim of the study was to analyze cytokine profiles in amniotic fluid (AF) samples of children developing autism spectrum disorders (ASD) and controls, adjusting for maternal autoimmune disorders and maternal infections during pregnancy.......The aim of the study was to analyze cytokine profiles in amniotic fluid (AF) samples of children developing autism spectrum disorders (ASD) and controls, adjusting for maternal autoimmune disorders and maternal infections during pregnancy....

  12. [Diagnosis: synovial fluid analysis].

    Science.gov (United States)

    Gallo Vallejo, Francisco Javier; Giner Ruiz, Vicente

    2014-01-01

    Synovial fluid analysis in rheumatological diseases allows a more accurate diagnosis in some entities, mainly infectious and microcrystalline arthritis. Examination of synovial fluid in patients with osteoarthritis is useful if a differential diagnosis will be performed with other processes and to distinguish between inflammatory and non-inflammatory forms. Joint aspiration is a diagnostic and sometimes therapeutic procedure that is available to primary care physicians. Copyright © 2014 Elsevier España, S.L. All rights reserved.

  13. Fullerol ionic fluids

    KAUST Repository

    Fernandes, Nikhil

    2010-01-01

    We report for the first time an ionic fluid based on hydroxylated fullerenes (fullerols). The ionic fluid was synthesized by neutralizing the fully protonated fullerol with an amine terminated polyethylene/polypropylene oxide oligomer (Jeffamine®). The ionic fluid was compared to a control synthesized by mixing the partially protonated form (sodium form) of the fullerols with the same oligomeric amine in the same ratio as in the ionic fluids (20 wt% fullerol). In the fullerol fluid the ionic bonding significantly perturbs the thermal transitions and melting/crystallization behavior of the amine. In contrast, both the normalized heat of fusion and crystallization of the amine in the control are similar to those of the neat amine consistent with a physical mixture of the fullerols/amine with minimal interactions. In addition to differences in thermal behavior, the fullerol ionic fluid exhibits a complex viscoelastic behavior intermediate between the neat Jeffamine® (liquid-like) and the control (solid-like). © 2010 The Royal Society of Chemistry.

  14. Thermostating highly confined fluids.

    Science.gov (United States)

    Bernardi, Stefano; Todd, B D; Searles, Debra J

    2010-06-28

    In this work we show how different use of thermostating devices and modeling of walls influence the mechanical and dynamical properties of confined nanofluids. We consider a two dimensional fluid undergoing Couette flow using nonequilibrium molecular dynamics simulations. Because the system is highly inhomogeneous, the density shows strong fluctuations across the channel. We compare the dynamics produced by applying a thermostating device directly to the fluid with that obtained when the wall is thermostated, considering also the effects of using rigid walls. This comparison involves an analysis of the chaoticity of the fluid and evaluation of mechanical properties across the channel. We look at two thermostating devices with either rigid or vibrating atomic walls and compare them with a system only thermostated by conduction through vibrating atomic walls. Sensitive changes are observed in the xy component of the pressure tensor, streaming velocity, and density across the pore and the Lyapunov localization of the fluid. We also find that the fluid slip can be significantly reduced by rigid walls. Our results suggest caution in interpreting the results of systems in which fluid atoms are thermostated and/or wall atoms are constrained to be rigid, such as, for example, water inside carbon nanotubes.

  15. Biological Pathways

    Science.gov (United States)

    Skip to main content Biological Pathways Fact Sheet Enter Search Term(s): Español Research Funding An Overview Bioinformatics Current Grants Education and Training Funding Extramural Research News Features ...

  16. statistical fluid theory for associating fluids containing alternating ...

    Indian Academy of Sciences (India)

    Abstract. Statistical associating fluid theory of homonuclear dimerized chain fluids and homonuclear monomer-dimer mixture chain fluids are extended to fluids containing al- ternating heteronuclear chain molecules separately. The proposed models account for the appropriate site-site correlation functions at contact.

  17. Two-phase cooling fluids; Les fluides frigoporteurs diphasiques

    Energy Technology Data Exchange (ETDEWEB)

    Lallemand, A. [Institut National des Sciences Appliquees (INSA), 69 - Lyon (France)

    1997-12-31

    In the framework of the diminution of heat transfer fluid consumption, the concept of indirect refrigerating circuits, using cooling intermediate fluids, is reviewed and the fluids that are currently used in these systems are described. Two-phase cooling fluids advantages over single-phase fluids are presented with their thermophysical characteristics: solid fraction, two-phase mixture enthalpy, thermal and rheological properties, determination of heat and mass transfer characteristics, and cold storage through ice slurry

  18. Viscous Flow with Large Fluid-Fluid Interface Displacement

    DEFF Research Database (Denmark)

    Rasmussen, Henrik Koblitz; Hassager, Ole; Saasen, Arild

    1998-01-01

    The arbitrary Lagrange-Euler (ALE) kinematic description has been implemented in a 3D transient finite element program to simulate multiple fluid flows with fluid-fluid interface or surface displacements. The description of fluid interfaces includes variable interfacial tension, and the formulation...... is useful in the simulation of low and intermediate Reynolds number viscous flow. The displacement of two immiscible Newtonian fluids in a vertical (concentric and eccentric) annulus and a (vertical and inclined)tube is simulated....

  19. Forensic body fluid identification: state of the art

    OpenAIRE

    Harbison, SallyAnn; Fleming,Rachel

    2016-01-01

    SA Harbison, RI Fleming Forensic Biology, Institute of Environmental Science and Research Ltd, Mt Albert Science Centre, Auckland, New Zealand Abstract: Body fluid identification is a key component in the forensic scientists' tool box and has been carried out both at the crime scene and in the laboratory for many years. Historically, methods relied on (bio) chemical-based tests, many of which lacked specificity. In this review, current technologies for identifying body fluids are des...

  20. Physics of biological membranes

    Science.gov (United States)

    Mouritsen, Ole G.

    The biological membrane is a complex system consisting of an aqueous biomolecular planar aggregate of predominantly lipid and protein molecules. At physiological temperatures, the membrane may be considered a thin (˜50Å) slab of anisotropic fluid characterized by a high lateral mobility of the various molecular components. A substantial fraction of biological activity takes place in association with membranes. As a very lively piece of condensed matter, the biological membrane is a challenging research topic for both the experimental and theoretical physicists who are facing a number of fundamental physical problems including molecular self-organization, macromolecular structure and dynamics, inter-macromolecular interactions, structure-function relationships, transport of energy and matter, and interfacial forces. This paper will present a brief review of recent theoretical and experimental progress on such problems, with special emphasis on lipid bilayer structure and dynamics, lipid phase transitions, lipid-protein and lipid-cholesterol interactions, intermembrane forces, and the physical constraints imposed on biomembrane function and evolution. The paper advocates the dual point of view that there are a number of interesting physics problems in membranology and, at the same time, that the physical properties of biomembranes are important regulators of membrane function.

  1. Hazardous fluid leak detector

    Science.gov (United States)

    Gray, Harold E.; McLaurin, Felder M.; Ortiz, Monico; Huth, William A.

    1996-01-01

    A device or system for monitoring for the presence of leaks from a hazardous fluid is disclosed which uses two electrodes immersed in deionized water. A gas is passed through an enclosed space in which a hazardous fluid is contained. Any fumes, vapors, etc. escaping from the containment of the hazardous fluid in the enclosed space are entrained in the gas passing through the enclosed space and transported to a closed vessel containing deionized water and two electrodes partially immersed in the deionized water. The electrodes are connected in series with a power source and a signal, whereby when a sufficient number of ions enter the water from the gas being bubbled through it (indicative of a leak), the water will begin to conduct, thereby allowing current to flow through the water from one electrode to the other electrode to complete the circuit and activate the signal.

  2. Rheology of Active Fluids

    Science.gov (United States)

    Saintillan, David

    2018-01-01

    An active fluid denotes a viscous suspension of particles, cells, or macromolecules able to convert chemical energy into mechanical work by generating stresses on the microscale. By virtue of this internal energy conversion, these systems display unusual macroscopic rheological signatures, including a curious transition to an apparent superfluid-like state where internal activity exactly compensates viscous dissipation. These behaviors are unlike those of classical complex fluids and result from the coupling of particle configurations with both externally applied flows and internally generated fluid disturbances. Focusing on the well-studied example of a suspension of microswimmers, this review summarizes recent experiments, models, and simulations in this area and highlights the critical role played by the rheological response of these active materials in a multitude of phenomena, from the enhanced transport of passive suspended objects to the emergence of spontaneous flows and collective motion.

  3. Biological preconcentrator

    Science.gov (United States)

    Manginell, Ronald P [Albuquerque, NM; Bunker, Bruce C [Albuquerque, NM; Huber, Dale L [Albuquerque, NM

    2008-09-09

    A biological preconcentrator comprises a stimulus-responsive active film on a stimulus-producing microfabricated platform. The active film can comprise a thermally switchable polymer film that can be used to selectively absorb and desorb proteins from a protein mixture. The biological microfabricated platform can comprise a thin membrane suspended on a substrate with an integral resistive heater and/or thermoelectric cooler for thermal switching of the active polymer film disposed on the membrane. The active polymer film can comprise hydrogel-like polymers, such as poly(ethylene oxide) or poly(n-isopropylacrylamide), that are tethered to the membrane. The biological preconcentrator can be fabricated with semiconductor materials and technologies.

  4. Digging Deep into Peptidomics Applied to Body Fluids.

    Science.gov (United States)

    Vitorino, Rui

    2018-01-01

    Peptidomics techniques have allowed the identification of thousands of peptides that are derived from proteins in body fluids, despite the considerable challenges behind sample handling, MS-based identification, data analysis, and integration with bioinformatics tools. Body fluids' naturally occurring peptides are known to perform a variety of local and systemic functions; however, its knowledge is limited. Even so, the biological meaning that can be retrieved from peptidomics applied to the identification of disease markers and to the development of therapies using peptides has driven the progresses made in this field. In this review, a comparative analysis of body fluids' peptidome data retrieved from databases and from scientific papers is performed to identify the biological processes modulated by naturally occurring peptides. This integrative analysis highlights several interesting facts, such as the small overlap between blood-derived serum and plasma, which illustrates the impact of sample handling on these fluids peptidome. Urine is the body fluid with more naturally occurring peptides identified so far, most of which are derived from collagens. In saliva, the majority of peptides are originated from extracellular matrix proteins. Cerebrospinal fluid presents a high number of peptides derived from distinct proteins, mostly involved in the regulation of nervous system homeostasis. The lowest number of endogenous peptides was found in tears, most of which present antimicrobial activity. Collectively, data analysis highlights a peptidome signature for each body fluid, which comprehension will certainly help to improve disease management. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  5. Biological transportation networks: Modeling and simulation

    KAUST Repository

    Albi, Giacomo

    2015-09-15

    We present a model for biological network formation originally introduced by Cai and Hu [Adaptation and optimization of biological transport networks, Phys. Rev. Lett. 111 (2013) 138701]. The modeling of fluid transportation (e.g., leaf venation and angiogenesis) and ion transportation networks (e.g., neural networks) is explained in detail and basic analytical features like the gradient flow structure of the fluid transportation network model and the impact of the model parameters on the geometry and topology of network formation are analyzed. We also present a numerical finite-element based discretization scheme and discuss sample cases of network formation simulations.

  6. Biological rhythms

    Science.gov (United States)

    Halberg, F.

    1975-01-01

    An overview is given of basic features of biological rhythms. The classification of periodic behavior of physical and psychological characteristics as circadian, circannual, diurnal, and ultradian is discussed, and the notion of relativistic time as it applies in biology is examined. Special attention is given to circadian rhythms which are dependent on the adrenocortical cycle. The need for adequate understanding of circadian variations in the basic physiological indicators of an individual (heart rate, body temperature, systolic and diastolic blood pressure, etc.) to ensure the effectiveness of prophylactic and therapeutic measures is stressed.

  7. Computational fluid dynamics

    CERN Document Server

    Magoules, Frederic

    2011-01-01

    Exploring new variations of classical methods as well as recent approaches appearing in the field, Computational Fluid Dynamics demonstrates the extensive use of numerical techniques and mathematical models in fluid mechanics. It presents various numerical methods, including finite volume, finite difference, finite element, spectral, smoothed particle hydrodynamics (SPH), mixed-element-volume, and free surface flow.Taking a unified point of view, the book first introduces the basis of finite volume, weighted residual, and spectral approaches. The contributors present the SPH method, a novel ap

  8. On radiative fluids

    International Nuclear Information System (INIS)

    Straumann, N.

    1976-01-01

    The Thomas calculation of the energy-momentum tensor of radiation quanta, which are nearly in thermal equilibrium with a relativistically moving material medium, is simplified and extended to more general transport equations. It is shown that the fluid (matter plus radiation) behaves, independently of the detailed form of the Boltzmann equation, like a relativistic imperfect fluid (in the formulation of Eckart). General expressions for the coefficients of heat conduction, shear viscosity and bulk viscosity are given. Published formulae for these coefficients in special cases are corrected. (Auth.)

  9. Mechanics of fluid flow

    CERN Document Server

    Basniev, Kaplan S; Chilingar, George V 0

    2012-01-01

    The mechanics of fluid flow is a fundamental engineering discipline explaining both natural phenomena and human-induced processes, and a thorough understanding of it is central to the operations of the oil and gas industry.  This book, written by some of the world's best-known and respected petroleum engineers, covers the concepts, theories, and applications of the mechanics of fluid flow for the veteran engineer working in the field and the student, alike.  It is a must-have for any engineer working in the oil and gas industry.

  10. Marine Biology

    Science.gov (United States)

    Dewees, Christopher M.; Hooper, Jon K.

    1976-01-01

    A variety of informational material for a course in marine biology or oceanology at the secondary level is presented. Among the topics discussed are: food webs and pyramids, planktonic blooms, marine life, plankton nets, food chains, phytoplankton, zooplankton, larval plankton and filter feeders. (BT)

  11. Mesoscopic biology

    Indian Academy of Sciences (India)

    Abstract. In this paper we present a qualitative outlook of mesoscopic biology where the typical length scale is of the order of nanometers and the energy scales comparable to thermal energy. Novel biomolecular machines, governed by coded information at the level of DNA and proteins, operate at these length scales in ...

  12. Scaffolded biology.

    Science.gov (United States)

    Minelli, Alessandro

    2016-09-01

    Descriptions and interpretations of the natural world are dominated by dichotomies such as organism vs. environment, nature vs. nurture, genetic vs. epigenetic, but in the last couple of decades strong dissatisfaction with those partitions has been repeatedly voiced and a number of alternative perspectives have been suggested, from perspectives such as Dawkins' extended phenotype, Turner's extended organism, Oyama's Developmental Systems Theory and Odling-Smee's niche construction theory. Last in time is the description of biological phenomena in terms of hybrids between an organism (scaffolded system) and a living or non-living scaffold, forming unit systems to study processes such as reproduction and development. As scaffold, eventually, we can define any resource used by the biological system, especially in development and reproduction, without incorporating it as happens in the case of resources fueling metabolism. Addressing biological systems as functionally scaffolded systems may help pointing to functional relationships that can impart temporal marking to the developmental process and thus explain its irreversibility; revisiting the boundary between development and metabolism and also regeneration phenomena, by suggesting a conceptual framework within which to investigate phenomena of regular hypermorphic regeneration such as characteristic of deer antlers; fixing a periodization of development in terms of the times at which a scaffolding relationship begins or is terminated; and promoting plant galls to legitimate study objects of developmental biology.

  13. Biological digestion

    International Nuclear Information System (INIS)

    Rosevear, A.

    1988-01-01

    This paper discusses the biological degradation of non-radioactive organic material occurring in radioactive wastes. The biochemical steps are often performed using microbes or isolated enzymes in combination with chemical steps and the aim is to oxidise the carbon, hydrogen, nitrogen and sulphur to their respective oxides. (U.K.)

  14. Biology Notes.

    Science.gov (United States)

    School Science Review, 1981

    1981-01-01

    Outlines a variety of laboratory procedures, techniques, and materials including construction of a survey frame for field biology, a simple tidal system, isolation and applications of plant protoplasts, tropisms, teaching lung structure, and a key to statistical methods for biologists. (DS)

  15. Fluorometric determination of d-lactate in biological fluids

    DEFF Research Database (Denmark)

    Larsen, Torben

    2017-01-01

    Objective D-lactic acid in the mammalian body is mainly of microbiological origin and is often located somewhere along the digestive tract. Surgical, extensive re-sectioning of the small bowel may be one of the risk factors for altered balance in the microbiological environment. Higher levels in ...

  16. Functionalized diamond nanopowder for phosphopeptides enrichment from complex biological fluids

    Energy Technology Data Exchange (ETDEWEB)

    Hussain, Dilshad [Division of Analytical Chemistry, Institute of Chemical Sciences, Bahauddin Zakariya University, Multan 60800 (Pakistan); Najam-ul-Haq, Muhammad, E-mail: najamulhaq@bzu.edu.pk [Division of Analytical Chemistry, Institute of Chemical Sciences, Bahauddin Zakariya University, Multan 60800 (Pakistan); Institute of Analytical Chemistry and Radiochemistry, Leopold-Franzens University, Innrain 80-82, A-6020 Innsbruck (Austria); Jabeen, Fahmida; Ashiq, Muhammad N.; Athar, Muhammad [Division of Analytical Chemistry, Institute of Chemical Sciences, Bahauddin Zakariya University, Multan 60800 (Pakistan); Rainer, Matthias; Huck, Christian W.; Bonn, Guenther K. [Institute of Analytical Chemistry and Radiochemistry, Leopold-Franzens University, Innrain 80-82, A-6020 Innsbruck (Austria)

    2013-05-02

    Graphical abstract: -- Highlights: •Derivatization of diamond nanopowder as IMAC and RP. •Characterization with SEM, EDX and FT-IR. •Phosphopeptide enrichment from standard as well as real samples. •Desalting and human serum profiling with reproducible results. •MALDI-MS analysis with database identification. -- Abstract: Diamond is known for its high affinity and biocompatibility towards biomolecules and is used exclusively in separation sciences and life science research. In present study, diamond nanopowder is derivatized as Immobilized Metal Ion Affinity Chromatographic (IMAC) material for the phosphopeptides enrichment and as Reversed Phase (C-18) media for the desalting of complex mixtures and human serum profiling through MALDI-TOF-MS. Functionalized diamond nanopowder is characterized by Fourier transform infrared (FT-IR) spectroscopy, scanning electron microscopy (SEM) and energy dispersive X-ray (EDX) spectroscopy. Diamond-IMAC is applied to the standard protein (β-casein), spiked human serum, egg yolk and non-fat milk for the phosphopeptides enrichment. Results show the selectivity of synthesized IMAC-diamond immobilized with Fe{sup 3+} and La{sup 3+} ions. To comprehend the elaborated use, diamond-IMAC is also applied to the serum samples from gall bladder carcinoma for the potential biomarkers. Database search is carried out by the Mascot program ( (www.matrixscience.com)) for the assignment of phosphorylation sites. Diamond nanopowder is thus a separation media with multifunctional use and can be applied to cancer protein profiling for the diagnosis and biomarker identification.

  17. Ion-pair extraction of [3]histobadine from biological fluids

    International Nuclear Information System (INIS)

    Scasnar, V.

    1997-01-01

    A simple and specific radiometric assay was developed for determination of stobadine, a cardio protective drug, in the serum of experimental animals. It is based on a single extraction step of the radioactively labeled drug from serum into the benzene solution of dicarbolide of cobalt followed by the quantitation of the extracted radioactivity by using liquid scintillation counting. The extraction mechanism involves the ion-pair formation between the protonized molecule of stobadine and the hydrophobic, negatively charged molecule of dicarbollide of cobalt. The extraction of yield of stobadine from 1 ml of serum was 95% in the concentration range from 1 to 6000 ng/ml. The co extraction of metabolites was less than 5%. The assay was applied to determination of stobadine in serum of dogs and the data obtained were in good agreement with those obtained by high performance liquid chromatography. (author)

  18. Biological activity of coelomic fluid of Eisenia foetida

    Czech Academy of Sciences Publication Activity Database

    Větvička, V.; Šíma, Petr; Hernychová, L.

    1997-01-01

    Roč. 21, č. 2 (1997), s. 114 ISSN 0145-305X. [Congress of the International Society of Developmental and Comparative Immunology /7./. Williamsburg, 21.07.1997-25.07.1997] Impact factor: 1.318, year: 1997

  19. Modeling high gradient magnetic separation from biological fluids.

    Energy Technology Data Exchange (ETDEWEB)

    Bockenfeld, D.; Chen, H.; Rempfer, D.; Kaminski, M. D.; Rosengart, A. J.; Chemical Engineering; Illinois Inst. of Tech.; Univ. of Chicago, Pritzker School of Medicine

    2006-01-01

    A proposed portable magnetic separator consists of an array of biocompatible capillary tubing and magnetizable wires immersed in an externally applied homogeneous magnetic field. While subject to the homogeneous magnetic field, the wires create high magnetic field gradients, which aid in the collection of blood-borne magnetic nanospheres from blood flow. In this study, a 3-D numerical model was created using COMSOL Multiphysics 3.2 software to determine the configuration of the wire-tubing array from two possible configurations, one being an array with rows alternating between wires and tubing, and the other being an array where wire and tubing alternate in two directions. The results demonstrated that the second configuration would actually capture more of the magnetic spheres. Experimental data obtained by our group support this numerical result.

  20. Fundamental Fluid Mechanics

    Indian Academy of Sciences (India)

    umes by P N Chatterjee contains standard material for a first level course in fluid me- chanics for Civil, Mechanical, Aeronautical and Chemical Engineering students. It is however not suitable for Applied Science students like those majoring in Physics or. Mathematics and is not a good reference book for practising ...

  1. Relativistic viscoelastic fluid mechanics.

    Science.gov (United States)

    Fukuma, Masafumi; Sakatani, Yuho

    2011-08-01

    A detailed study is carried out for the relativistic theory of viscoelasticity which was recently constructed on the basis of Onsager's linear nonequilibrium thermodynamics. After rederiving the theory using a local argument with the entropy current, we show that this theory universally reduces to the standard relativistic Navier-Stokes fluid mechanics in the long time limit. Since effects of elasticity are taken into account, the dynamics at short time scales is modified from that given by the Navier-Stokes equations, so that acausal problems intrinsic to relativistic Navier-Stokes fluids are significantly remedied. We in particular show that the wave equations for the propagation of disturbance around a hydrostatic equilibrium in Minkowski space-time become symmetric hyperbolic for some range of parameters, so that the model is free of acausality problems. This observation suggests that the relativistic viscoelastic model with such parameters can be regarded as a causal completion of relativistic Navier-Stokes fluid mechanics. By adjusting parameters to various values, this theory can treat a wide variety of materials including elastic materials, Maxwell materials, Kelvin-Voigt materials, and (a nonlinearly generalized version of) simplified Israel-Stewart fluids, and thus we expect the theory to be the most universal description of single-component relativistic continuum materials. We also show that the presence of strains and the corresponding change in temperature are naturally unified through the Tolman law in a generally covariant description of continuum mechanics.

  2. Incompressible ionized fluid mixtures

    Czech Academy of Sciences Publication Activity Database

    Roubíček, Tomáš

    2006-01-01

    Roč. 17, č. 7 (2006), s. 493-509 ISSN 0935-1175 Institutional research plan: CEZ:AV0Z10750506 Keywords : chemically reacting fluids * Navier-Stokes * Nernst-Planck * Possion equation s * heat equation s Subject RIV: BA - General Mathematics Impact factor: 0.954, year: 2006

  3. Bouncy Fluid Jets

    Science.gov (United States)

    Wadhwa, Navish; Jung, Sunghwan; Vlachos, Pavlos

    2012-11-01

    Contrary to intuition, free fluid jets can sometimes ``bounce'' off each other upon collision, due to an entrained air film that keeps them separated. So far, there have only been a few descriptive studies of bouncing jets, since the first recorded observation by Rayleigh more than a century ago. We present a quantitative investigation of non-coalescence in jets of same fluid upon an oblique collision. Using a simple experimental set-up, we carried out a parametric study of the bouncing jets by varying the jet diameter, velocity, angle of inclination and fluid viscosity. Our results reveal a scaling law for the contact time of bouncing jets. We further investigate the transition of colliding jets from non-coalescence to coalescence, which seems to be caused by instability of the fluid interface. A dimensionless parameter, which is a function of the Normal Weber Number, Normal Reynolds Number and the angle of inclination of the jets, quantitatively dictates the transition. Presently at Department of Physics, Danish Technical University, Denmark.

  4. Relativistic viscoelastic fluid mechanics

    International Nuclear Information System (INIS)

    Fukuma, Masafumi; Sakatani, Yuho

    2011-01-01

    A detailed study is carried out for the relativistic theory of viscoelasticity which was recently constructed on the basis of Onsager's linear nonequilibrium thermodynamics. After rederiving the theory using a local argument with the entropy current, we show that this theory universally reduces to the standard relativistic Navier-Stokes fluid mechanics in the long time limit. Since effects of elasticity are taken into account, the dynamics at short time scales is modified from that given by the Navier-Stokes equations, so that acausal problems intrinsic to relativistic Navier-Stokes fluids are significantly remedied. We in particular show that the wave equations for the propagation of disturbance around a hydrostatic equilibrium in Minkowski space-time become symmetric hyperbolic for some range of parameters, so that the model is free of acausality problems. This observation suggests that the relativistic viscoelastic model with such parameters can be regarded as a causal completion of relativistic Navier-Stokes fluid mechanics. By adjusting parameters to various values, this theory can treat a wide variety of materials including elastic materials, Maxwell materials, Kelvin-Voigt materials, and (a nonlinearly generalized version of) simplified Israel-Stewart fluids, and thus we expect the theory to be the most universal description of single-component relativistic continuum materials. We also show that the presence of strains and the corresponding change in temperature are naturally unified through the Tolman law in a generally covariant description of continuum mechanics.

  5. Cryogenic Fluid Management Facility

    Science.gov (United States)

    Eberhardt, R. N.; Bailey, W. J.

    1985-01-01

    The Cryogenic Fluid Management Facility is a reusable test bed which is designed to be carried within the Shuttle cargo bay to investigate the systems and technologies associated with the efficient management of cryogens in space. Cryogenic fluid management consists of the systems and technologies for: (1) liquid storage and supply, including capillary acquisition/expulsion systems which provide single-phase liquid to the user system, (2) both passive and active thermal control systems, and (3) fluid transfer/resupply systems, including transfer lines and receiver tanks. The facility contains a storage and supply tank, a transfer line and a receiver tank, configured to provide low-g verification of fluid and thermal models of cryogenic storage and transfer processes. The facility will provide design data and criteria for future subcritical cryogenic storage and transfer system applications, such as Space Station life support, attitude control, power and fuel depot supply, resupply tankers, external tank (ET) propellant scavenging, and ground-based and space-based orbit transfer vehicles (OTV).

  6. Fluids in metamorphic rocks

    NARCIS (Netherlands)

    Touret, J.L.R.

    2001-01-01

    Basic principles for the study of fluid inclusions in metamorphic rocks are reviewed and illustrated. A major problem relates to the number of inclusions, possibly formed on a wide range of P-T conditions, having also suffered, in most cases, extensive changes after initial trapping. The

  7. Charged fluids with symmetries

    Indian Academy of Sciences (India)

    metric tensor field and generate constants of the motion along null geodesics for massless particles. Conformal symmetries arise in various physical applications. The existence of conformal symmetries in relativistic cosmological models, with restrictions on the matter content and fluid four-velocity, have been extensively ...

  8. NASA's Microgravity Fluid Physics Strategic Research Roadmap

    Science.gov (United States)

    Motil, Brian J.; Singh, Bhim S.

    2004-01-01

    The Microgravity Fluid Physics Program at NASA has developed a substantial investigator base engaging a broad crosssection of the U.S. scientific community. As a result, it enjoys a rich history of many significant scientific achievements. The research supported by the program has produced many important findings that have been published in prestigious journals such as Science, Nature, Journal of Fluid Mechanics, Physics of Fluids, and many others. The focus of the program so far has primarily been on fundamental scientific studies. However, a recent shift in emphasis at NASA to develop advanced technologies to enable future exploration of space has provided motivation to add a strategic research component to the program. This has set into motion a year of intense planning within NASA including three workshops to solicit inputs from the external scientific community. The planning activities and the workshops have resulted in a prioritized list of strategic research issues along with a corresponding detailed roadmap specific to fluid physics. The results of these activities were provided to NASA s Office of Biological and Physical Research (OBPR) to support the development of the Enterprise Strategy document. This paper summarizes these results while showing how the planned research supports NASA s overall vision through OBPR s organizing questions.

  9. Finite Element Framework for Computational Fluid Dynamics in FEBio.

    Science.gov (United States)

    Ateshian, Gerard A; Shim, Jay J; Maas, Steve A; Weiss, Jeffrey A

    2018-02-01

    The mechanics of biological fluids is an important topic in biomechanics, often requiring the use of computational tools to analyze problems with realistic geometries and material properties. This study describes the formulation and implementation of a finite element framework for computational fluid dynamics (CFD) in FEBio, a free software designed to meet the computational needs of the biomechanics and biophysics communities. This formulation models nearly incompressible flow with a compressible isothermal formulation that uses a physically realistic value for the fluid bulk modulus. It employs fluid velocity and dilatation as essential variables: The virtual work integral enforces the balance of linear momentum and the kinematic constraint between fluid velocity and dilatation, while fluid density varies with dilatation as prescribed by the axiom of mass balance. Using this approach, equal-order interpolations may be used for both essential variables over each element, contrary to traditional mixed formulations that must explicitly satisfy the inf-sup condition. The formulation accommodates Newtonian and non-Newtonian viscous responses as well as inviscid fluids. The efficiency of numerical solutions is enhanced using Broyden's quasi-Newton method. The results of finite element simulations were verified using well-documented benchmark problems as well as comparisons with other free and commercial codes. These analyses demonstrated that the novel formulation introduced in FEBio could successfully reproduce the results of other codes. The analogy between this CFD formulation and standard finite element formulations for solid mechanics makes it suitable for future extension to fluid-structure interactions (FSIs).

  10. Edge instability in incompressible planar active fluids

    Science.gov (United States)

    Nesbitt, David; Pruessner, Gunnar; Lee, Chiu Fan

    2017-12-01

    Interfacial instability is highly relevant to many important biological processes. A key example arises in wound healing experiments, which observe that an epithelial layer with an initially straight edge does not heal uniformly. We consider the phenomenon in the context of active fluids. Improving upon the approximation used by Zimmermann, Basan, and Levine [Eur. Phys. J.: Spec. Top. 223, 1259 (2014), 10.1140/epjst/e2014-02189-7], we perform a linear stability analysis on a two-dimensional incompressible hydrodynamic model of an active fluid with an open interface. We categorize the stability of the model and find that for experimentally relevant parameters, fingering instability is always absent in this minimal model. Our results point to the crucial role of density variation in the fingering instability in tissue regeneration.

  11. Biologic Scaffolds.

    Science.gov (United States)

    Costa, Alessandra; Naranjo, Juan Diego; Londono, Ricardo; Badylak, Stephen F

    2017-09-01

    Biologic scaffold materials composed of allogeneic or xenogeneic extracellular matrix are commonly used for the repair and functional reconstruction of injured and missing tissues. These naturally occurring bioscaffolds are manufactured by the removal of the cellular content from source tissues while preserving the structural and functional molecular units of the remaining extracellular matrix (ECM). The mechanisms by which these bioscaffolds facilitate constructive remodeling and favorable clinical outcomes include release or creation of effector molecules that recruit endogenous stem/progenitor cells to the site of scaffold placement and modulation of the innate immune response, specifically the activation of an anti-inflammatory macrophage phenotype. The methods by which ECM biologic scaffolds are prepared, the current understanding of in vivo scaffold remodeling, and the associated clinical outcomes are discussed in this article. Copyright © 2017 Cold Spring Harbor Laboratory Press; all rights reserved.

  12. Biological radioprotector

    International Nuclear Information System (INIS)

    Stefanescu, Ioan; Titescu, Gheorghe; Tamaian, Radu; Haulica, Ion; Bild, Walther

    2002-01-01

    According to the patent description, the biological radioprotector is deuterium depleted water, DDW, produced by vacuum distillation with an isotopic content lower than natural value. It appears as such or in a mixture with natural water and carbon dioxide. It can be used for preventing and reducing the ionizing radiation effects upon humans or animal organisms, exposed therapeutically, professionally or accidentally to radiation. The most significant advantage of using DDW as biological radioprotector results from its way of administration. Indeed no one of the radioprotectors currently used today can be orally administrated, what reduces the patients' compliance to prophylactic administrations. The biological radioprotector is an unnoxious product obtained from natural water, which can be administrated as food additive instead of drinking water. Dose modification factor is according to initial estimates around 1.9, what is a remarkable feature when one takes into account that the product is toxicity-free and side effect-free and can be administrated prophylactically as a food additive. A net radioprotective action of the deuterium depletion was evidenced experimentally in laboratory animals (rats) hydrated with DDW of 30 ppm D/(D+H) concentration as compared with normally hydrated control animals. Knowing the effects of irradiation and mechanisms of the acute radiation disease as well as the effects of administration of radiomimetic chemicals upon cellular lines of fast cell division, it appears that the effects of administrating DDW result from stimulation of the immunity system. In conclusion, the biological radioprotector DDW presents the following advantages: - it is obtained from natural products without toxicity; - it is easy to be administrated as a food additive, replacing the drinking water; - besides radioprotective effects, the product has also immunostimulative and antitumoral effects

  13. Crusts: biological

    Science.gov (United States)

    Belnap, Jayne; Elias, Scott A.

    2013-01-01

    Biological soil crusts, a community of cyanobacteria, lichens, mosses, and fungi, are an essential part of dryland ecosystems. They are critical in the stabilization of soils, protecting them from wind and water erosion. Similarly, these soil surface communities also stabilized soils on early Earth, allowing vascular plants to establish. They contribute nitrogen and carbon to otherwise relatively infertile dryland soils, and have a strong influence on hydrologic cycles. Their presence can also influence vascular plant establishment and nutrition.

  14. Editorial Special Issue on Fluid Mechanics and Fluid Power (FMFP ...

    Indian Academy of Sciences (India)

    This special issue of Sadhana contains selected papers from two conferences related to fluid mechanics held in India recently, Fluid Mechanics and Fluid Power conference at NIT, Hamirpur, and an International Union of Theoretical and Applied Mechanics (IUTAM) symposium held at. Jawaharlal Nehru Centre for ...

  15. Marine biology

    International Nuclear Information System (INIS)

    Thurman, H.V.; Webber, H.H.

    1984-01-01

    This book discusses both taxonomic and ecological topics on marine biology. Full coverage of marine organisms of all five kingdoms is provided, along with interesting and thorough discussion of all major marine habitats. Organization into six major parts allows flexibility. It also provides insight into important topics such as disposal of nuclear waste at sea, the idea that life began on the ocean floor, and how whales, krill, and people interact. A full-color photo chapter reviews questions, and exercises. The contents are: an overview marine biology: fundamental concepts/investigating life in the ocean; the physical ocean, the ocean floor, the nature of water, the nature and motion of ocean water; general ecology, conditions for life in the sea, biological productivity and energy transfer; marine organisms; monera, protista, mycota and metaphyta; the smaller marine animals, the large animals marine habitats, the intertidal zone/benthos of the continental shelf, the photic zone, the deep ocean, the ocean under stress, marine pollution, appendix a: the metric system and conversion factors/ appendix b: prefixes and suffixes/ appendix c: taxonomic classification of common marine organisms, and glossary, and index

  16. R3 fluids

    Directory of Open Access Journals (Sweden)

    Caimmi R.

    2007-01-01

    Full Text Available The current paper is aimed at getting more insight on three main points concerning large-scale astrophysical systems, namely: (i formulation of tensor virial equations from the standpoint of analytical mechanics; (ii investigation on the role of systematic and random motions with respect to virial equilibrium configurations; (iii determination of extent to which systematic and random motions are equivalent in flattening or elongating the shape of a mass distribution. The tensor virial equations are formulated regardless of the nature of the system and its constituents, by generalizing and extending a procedure used for the scalar virial equations in presence of discrete subunits (Landau and Lifchitz 1966. In particular, the self potential-energy tensor is shown to be symmetric with respect to the exchange of the indices, (Epotpq = (Epotqp. Then the results are extended to continuous mass distributions. The role of systematic and random motions in collisionless, ideal, self-gravitating fluids is analysed in detail including radial and tangential velocity dispersion on the equatorial plane, and the related mean angular velocity, Ω, is conceived as a figure rotation. R3 fluids are defined as ideal, self-gravitating fluids in virial equilibrium, with systematic rotation around a principal axis of inertia, taken to be x3. The related virial equations are written in terms of the moment of inertia tensor, Ipq, the self potential-energy tensor, (Epotpq, and the generalized anisotropy tensor, ζpq (Caimmi and Marmo 2005, Caimmi 2006a. Additional effort is devoted to the investigation of the properties of axisymmetric and triaxial configurations. A unified theory of systematic and random motions is developed for R3 fluids, taking into consideration imaginary rotation (Caimmi 1996b, 2006a, and a number of theorems previously stated for homeoidally striated Jacobi ellipsoids (Caimmi 2006a are extended to the more general case of R3 fluids. The effect of

  17. Handbook of hydraulic fluid technology

    CERN Document Server

    Totten, George E

    2011-01-01

    ""The Handbook of Hydraulic Fluid Technology"" serves as the foremost resource for designing hydraulic systems and for selecting hydraulic fluids used in engineering applications. Featuring new illustrations, data tables, as well as practical examples, this second edition is updated with essential information on the latest hydraulic fluids and testing methods. The detailed text facilitates unparalleled understanding of the total hydraulic system, including important hardware, fluid properties, and hydraulic lubricants. Written by worldwide experts, the book also offers a rigorous overview of h

  18. Recording fluid currents by holography

    Science.gov (United States)

    Heflinger, L. O.; Wuerker, R. F.

    1980-01-01

    Convection in fluids can be studied with aid of holographic apparatus that reveals three-dimensional motion of liquid. Apparatus eliminates images of fixed particles such as dust on windows and lenses, which might mask behavior of moving fluid particles. Holographic apparatus was developed for experiments on fluid convection cells under zero gravity. Principle is adaptable to study of fluid processes-for example, electrochemical plating and combustion in automotive engines.

  19. Oscillating fluid power generator

    Science.gov (United States)

    Morris, David C

    2014-02-25

    A system and method for harvesting the kinetic energy of a fluid flow for power generation with a vertically oriented, aerodynamic wing structure comprising one or more airfoil elements pivotably attached to a mast. When activated by the moving fluid stream, the wing structure oscillates back and forth, generating lift first in one direction then in the opposite direction. This oscillating movement is converted to unidirectional rotational movement in order to provide motive power to an electricity generator. Unlike other oscillating devices, this device is designed to harvest the maximum aerodynamic lift forces available for a given oscillation cycle. Because the system is not subjected to the same intense forces and stresses as turbine systems, it can be constructed less expensively, reducing the cost of electricity generation. The system can be grouped in more compact clusters, be less evident in the landscape, and present reduced risk to avian species.

  20. COUPLED CHEMOTAXIS FLUID MODEL

    KAUST Repository

    LORZ, ALEXANDER

    2010-06-01

    We consider a model system for the collective behavior of oxygen-driven swimming bacteria in an aquatic fluid. In certain parameter regimes, such suspensions of bacteria feature large-scale convection patterns as a result of the hydrodynamic interaction between bacteria. The presented model consist of a parabolicparabolic chemotaxis system for the oxygen concentration and the bacteria density coupled to an incompressible Stokes equation for the fluid driven by a gravitational force of the heavier bacteria. We show local existence of weak solutions in a bounded domain in d, d = 2, 3 with no-flux boundary condition and in 2 in the case of inhomogeneous Dirichlet conditions for the oxygen. © 2010 World Scientific Publishing Company.

  1. Fluid dynamics an introduction

    CERN Document Server

    Rieutord, Michel

    2015-01-01

    This book is dedicated to readers who want to learn fluid dynamics from the beginning. It assumes a basic level of mathematics knowledge that would correspond to that of most second-year undergraduate physics students and examines fluid dynamics from a physicist’s perspective. As such, the examples used primarily come from our environment on Earth and, where possible, from astrophysics. The text is arranged in a progressive and educational format, aimed at leading readers from the simplest basics to more complex matters like turbulence and magnetohydrodynamics. Exercises at the end of each chapter help readers to test their understanding of the subject (solutions are provided at the end of the book), and a special chapter is devoted to introducing selected aspects of mathematics that beginners may not be familiar with, so as to make the book self-contained.

  2. Electrorheologic fluids; Fluidos electroreologicos

    Energy Technology Data Exchange (ETDEWEB)

    Rejon G, Leonardo; Lopez G, Francisco; Montoya T, Gerardo [Instituto de Investigaciones Electricas, Cuernavaca, Morelos (Mexico); Manero B, Octavio [Instituto de Investigaciones en Materiales, UNAM.(Mexico)

    2003-07-01

    The present article has as an objective to offer a review of the research work made in the Instituto de Investigaciones Electricas (IIE) on the study of the electrorheologic fluids whose flow properties can abruptly change in the presence of an electric field when this is induced by a direct current. The electrorheologic fluids have their main application in the manufacture of self-controlling damping systems. [Spanish] El presente articulo tiene por objetivo ofrecer una resena de los trabajos de investigacion realizados en el Instituto de Investigaciones Electricas (IIE) sobre el estudio de los fluidos electroreologicos cuyas propiedades de flujo pueden cambiar abruptamente en presencia de un campo electrico cuando este es inducido por una corriente directa. Los fluidos electroreologicos tienen su principal aplicacion en la fabricacion de sistemas de amortiguamiento autocontrolables.

  3. Flapping motion and force generation in a viscoelastic fluid

    Science.gov (United States)

    Normand, Thibaud; Lauga, Eric

    2008-12-01

    In a variety of biological situations, swimming cells have to move through complex fluids. Similarly, mucociliary clearance involves the transport of polymeric fluids by beating cilia. Here, we consider the extent to which complex fluids could be exploited for force generation on small scales. We consider a prototypical reciprocal motion (i.e., identical under time-reversal symmetry): the periodic flapping of a tethered semi-infinite plane. In the Newtonian limit, such motion cannot be used for force generation according to Purcell’s scallop theorem. In a polymeric fluid (Oldroyd-B, and its generalization), we show that this is not the case and calculate explicitly the forces on the flapper for small-amplitude sinusoidal motion. Three setups are considered: a flapper near a wall, a flapper in a wedge, and a two-dimensional scalloplike flapper. In all cases, we show that at quadratic order in the oscillation amplitude, the tethered flapping motion induces net forces, but no average flow. Our results demonstrate therefore that the scallop theorem is not valid in polymeric fluids. The reciprocal component of the movement of biological appendages such as cilia can thus generate nontrivial forces in polymeric fluid such as mucus, and normal-stress differences can be exploited as a pure viscoelastic force generation and propulsion method.

  4. 3D Suspended Polymeric Microfluidics (SPMF3) with Flow Orthogonal to Bending (FOB) for Fluid Analysis through Kinematic Viscosity

    OpenAIRE

    Mostapha Marzban; Muthukumaran Packirisamy; Javad Dargahi

    2017-01-01

    Measuring of fluid properties such as dynamic viscosity and density has tremendous potential for various applications from physical to biological to chemical sensing. However, it is almost impossible to affect only one of these properties, as dynamic viscosity and density are coupled. Hence, this paper proposes kinematic viscosity as a comprehensive parameter which can be used to study the effect of fluid properties applicable to various fluids from Newtonian fluids, such as water, to non-New...

  5. Magnetorheological Fluids and Elastomers

    Science.gov (United States)

    Ginder, John

    2002-03-01

    Magnetorheological (MR) materials possess mechanical or rheological properties that can be controlled by magnetic fields. MR fluids, perhaps the prototypical MR materials, comprise magnetically soft particles dispersed in polar or nonpolar liquids. The particles in these fluids align to form chains or more complex structures when a magnetic field is applied; these structures resist mechanical deformation, reversibly transforming the fluid into a weak viscoelastic solid. Other MR materials include magnetic powders, in which the magnetic particles are dispersed in air and which also become weak solids in an applied field. MR elastomers, a third class of these materials, contain magnetizable particles dispersed in elastomeric solids. These elastomers are magnetostrictive, possessing substantial field-induced modulus increases and elongations. The fascinating behavior of these materials, together with their many potential uses in the automobile and elsewhere, has motivated considerable scientific and technological progress over the last decade. While magnetic powders have been used in industrial applications for decades, the first components using MR fluids were marketed in the mid-1990s, and the first commercial automotive applications are imminent. In this presentation, I will survey the physical properties of MR materials and sketch our understanding of their origins, paying particular attention to the central role of field-induced interparticle magnetic forces and the nature and dynamics of the resulting microstructure. I will describe some possible automotive applications based on these materials, focusing on the material properties and component performance that is required. Finally, I will identify some of the open scientific and technical issues in this growing field.

  6. Fluid circulation control device

    International Nuclear Information System (INIS)

    Benard, Henri; Henocque, Jean.

    1982-01-01

    Horizontal fluid circulation control device, of the type having a pivoting flap. This device is intended for being fitted in the pipes of hydraulic installation, particularly in a bleed and venting system of a nuclear power station shifting radioactive or contaminated liquids. The characteristic of this device is the cut-out at the top of the flap to allow the air contained in the pipes to flow freely [fr

  7. Measuring fluid pressure

    International Nuclear Information System (INIS)

    Lee, A.S.

    1978-01-01

    A method and apparatus are described for measuring the pressure of a fluid having characteristics that make it unsuitable for connection directly to a pressure gauge. The method is particularly suitable for the periodic measurement of the pressure of a supply of liquid Na to Na-lubricated bearings of pumps for pumping Na from a reservoir to the bearing via a filter, the reservoir being contained in a closed vessel containing an inert blanket gas, such as Ar, above the Na. (UK)

  8. The mixing of fluids

    International Nuclear Information System (INIS)

    Ottino, J.M.

    1989-01-01

    What do the eruption of Krakatau, the manufacture of puff pastry and the brightness of stars have in common? Each involves some aspect of mixing. Mixing also plays a critical role in modern technology. Chemical engineers rely on mixing to ensure that substances react properly, to produce polymer blends that exhibit unique properties and to disperse drag-reducing agents in pipelines. Yet in spite of its of its ubiquity in nature and industry, mixing is only imperfectly under-stood. Indeed, investigators cannot even settle on a common terminology: mixing is often referred to as stirring by oceanographers and geophysicists, as blending by polymer engineers and as agitation by process engineers. Regardless of what the process is called, there is little doubt that it is exceedingly complex and is found in a great variety of systems. In constructing a theory of fluid mixing, for example, one has to take into account fluids that can be miscible or partially miscible and reactive or inert, and flows that are slow and orderly or very fast and turbulent. It is therefore not surprising that no single theory can explain all aspect of mixing in fluids and that straightforward computations usually fail to capture all the important details. Still, both physical experiments and computer simulations can provide insight into the mixing process. Over the past several years the authors and his colleague have taken both approaches in an effort to increase understanding of various aspect of the process-particularly of mixing involving slow flows and viscous fluids such as oils

  9. Downhole Fluid Analyzer Development

    Energy Technology Data Exchange (ETDEWEB)

    Bill Turner

    2006-11-28

    A novel fiber optic downhole fluid analyzer has been developed for operation in production wells. This device will allow real-time determination of the oil, gas and water fractions of fluids from different zones in a multizone or multilateral completion environment. The device uses near infrared spectroscopy and induced fluorescence measurement to unambiguously determine the oil, water and gas concentrations at all but the highest water cuts. The only downhole components of the system are the fiber optic cable and windows. All of the active components--light sources, sensors, detection electronics and software--will be located at the surface, and will be able to operate multiple downhole probes. Laboratory testing has demonstrated that the sensor can accurately determine oil, water and gas fractions with a less than 5 percent standard error. Once installed in an intelligent completion, this sensor will give the operating company timely information about the fluids arising from various zones or multilaterals in a complex completion pattern, allowing informed decisions to be made on controlling production. The research and development tasks are discussed along with a market analysis.

  10. Geophysical fluid dynamics

    CERN Document Server

    Pedlosky, Joseph

    1979-01-01

    The content of this book is based, largely, on the core curriculum in geophys­ ical fluid dynamics which I and my colleagues in the Department of Geophysical Sciences at The University of Chicago have taught for the past decade. Our purpose in developing a core curriculum was to provide to advanced undergraduates and entering graduate students a coherent and systematic introduction to the theory of geophysical fluid dynamics. The curriculum and the outline of this book were devised to form a sequence of courses of roughly one and a half academic years (five academic quarters) in length. The goal of the sequence is to help the student rapidly advance to the point where independent study and research are practical expectations. It quickly became apparent that several topics (e. g. , some aspects of potential theory) usually thought of as forming the foundations of a fluid-dynamics curriculum were merely classical rather than essential and could be, however sadly, dispensed with for our purposes. At the same ti...

  11. Geophysical fluid dynamics

    CERN Document Server

    Pedlosky, Joseph

    1982-01-01

    The content of this book is based, largely, on the core curriculum in geophys­ ical fluid dynamics which land my colleagues in the Department of Geophysical Sciences at The University of Chicago have taught for the past decade. Our purpose in developing a core curriculum was to provide to advanced undergraduates and entering graduate students a coherent and systematic introduction to the theory of geophysical fluid dynamics. The curriculum and the outline of this book were devised to form a sequence of courses of roughly one and a half academic years (five academic quarters) in length. The goal of the sequence is to help the student rapidly advance to the point where independent study and research are practical expectations. It quickly became apparent that several topics (e. g. , some aspects of potential theory) usually thought of as forming the foundations of a fluid-dynamics curriculum were merely classical rather than essential and could be, however sadly, dispensed with for our purposes. At the same tim...

  12. Astrophysical fluid dynamics

    Science.gov (United States)

    Ogilvie, Gordon I.

    2016-06-01

    > These lecture notes and example problems are based on a course given at the University of Cambridge in Part III of the Mathematical Tripos. Fluid dynamics is involved in a very wide range of astrophysical phenomena, such as the formation and internal dynamics of stars and giant planets, the workings of jets and accretion discs around stars and black holes and the dynamics of the expanding Universe. Effects that can be important in astrophysical fluids include compressibility, self-gravitation and the dynamical influence of the magnetic field that is `frozen in' to a highly conducting plasma. The basic models introduced and applied in this course are Newtonian gas dynamics and magnetohydrodynamics (MHD) for an ideal compressible fluid. The mathematical structure of the governing equations and the associated conservation laws are explored in some detail because of their importance for both analytical and numerical methods of solution, as well as for physical interpretation. Linear and nonlinear waves, including shocks and other discontinuities, are discussed. The spherical blast wave resulting from a supernova, and involving a strong shock, is a classic problem that can be solved analytically. Steady solutions with spherical or axial symmetry reveal the physics of winds and jets from stars and discs. The linearized equations determine the oscillation modes of astrophysical bodies, as well as their stability and their response to tidal forcing.

  13. Dynamics of radiating fluids

    International Nuclear Information System (INIS)

    Mihalas, D.; Weaver, R.

    1982-01-01

    The purpose of this paper is to give an overview of the role of radiation in the transport of energy and momentum in a combined matter-radiation fluid. The transport equation for a moving radiating fluid is presented in both a fully Eulerian and a fully Lagrangian formulation, along with conservation equations describing the dynamics of the fluid. Special attention is paid to the problem of deriving equations that are mutually consistent in each frame, and between frames, to 0(v/c). A detailed analysis is made to show that in situations of broad interest, terms that are formally of 0(v/c) actually dominate the solution, demonstrating that it is essential (1) to pay scrupulous attention to the question of the frame dependence in formulating the equations, and (2) to solve the equations to 0(v/c) in quite general circumstances. These points are illustrated in the context of the nonequilibrium radiation diffusion limit, and a sketch of how the Lagrangian equations are to be solved is presented

  14. Supercritical fluids cleaning

    Energy Technology Data Exchange (ETDEWEB)

    Butner, S.; Hjeresen, D.; Silva, L.; Spall, D.; Stephenson, R.

    1991-01-01

    This paper discusses a proposed multi-party research and development program which seeks to develop supercritical fluid cleaning technology as an alternative to existing solvent cleaning applications. While SCF extraction technology has been in commercial use for several years, the use of these fluids as cleaning agents poses several new technical challenges. Problems inherent in the commercialization of SCF technology include: the cleaning efficacy and compatibility of supercritical working fluids with the parts to be cleaned must be assessed for a variety of materials and components; process parameters and equipment design Have been optimized for extractive applications and must be reconsidered for application to cleaning; and co-solvents and entrainers must be identified to facilitate the removal of polar inorganic and organic contaminants, which are often not well solvated in supercritical systems. The proposed research and development program would address these issues and lead to the development and commercialization of viable SCF-based technology for precision cleaning applications. This paper provides the technical background, program scope, and delineates the responsibilities of each principal participant in the program.

  15. Fluid dynamics of bubbly flows

    International Nuclear Information System (INIS)

    Ziegenhein, Thomas

    2016-01-01

    Bubbly flows can be found in many applications in chemical, biological and power engineering. Reliable simulation tools of such flows that allow the design of new processes and optimization of existing one are therefore highly desirable. CFD-simulations applying the multi-fluid approach are very promising to provide such a design tool for complete facilities. In the multi-fluid approach, however, closure models have to be formulated to model the interaction between the continuous and dispersed phase. Due to the complex nature of bubbly flows, different phenomena have to be taken into account and for every phenomenon different closure models exist. Therefore, reliable predictions of unknown bubbly flows are not yet possible with the multi-fluid approach. A strategy to overcome this problem is to define a baseline model in which the closure models including the model constants are fixed so that the limitations of the modeling can be evaluated by validating it on different experiments. Afterwards, the shortcomings are identified so that the baseline model can be stepwise improved without losing the validity for the already validated cases. This development of a baseline model is done in the present work by validating the baseline model developed at the Helmholtz-Zentrum Dresden-Rossendorf mainly basing on experimental data for bubbly pipe flows to bubble columns, bubble plumes and air-lift reactors that are relevant in chemical and biological engineering applications. In the present work, a large variety of such setups is used for validation. The buoyancy driven bubbly flows showed thereby a transient behavior on the scale of the facility. Since such large scales are characterized by the geometry of the facility, turbulence models cannot describe them. Therefore, the transient simulation of bubbly flows with two equation models based on the unsteady Reynolds-averaged Navier-Stokes equations is investigated. In combination with the before mentioned baseline model these

  16. Fluid flow in a spiral device used for irradiation of biological fluids.

    Science.gov (United States)

    Nikolof, Todd; Prakash, Mahesh; Cleary, Paul W; Bertolini, Joseph

    2013-01-01

    The manufacture of plasma-derived therapeutics includes dedicated viral inactivation steps to minimize the risk of infection. Traditional viral inactivation methods are effective for the removal and inactivation of enveloped viruses, but less effective against small nonenveloped viruses. UV-C irradiation has been demonstrated to be an effective means of inactivating such viruses. The UVivatec lab system consists of a spiral tube around an UV-C irradiation source. Flow of a solution through the chamber generates and ensures controlled mixing and uniform exposure to irradiation. A detailed assessment of the effect of flow rate, alternate cross sectional design and scale up of the irradiation chamber on Dean vortices was performed using the smoothed particle hydrodynamics method. The aim was to provide a basis for setting flow rate limits and using a laboratory scale apparatus to model viral inactivation in larger manufacturing scale equipment. The effect of flow rate related changes on the fluence rate was also investigated through chemical actinometry studies. The data were consistent with the simulations indicating that Dean vortices were present at low flow rates, but dissipated at higher flow rates through the spiral chamber. Importantly, this work also allowed a correlation between the small system and large scale system to be established. This will greatly facilitate process development and viral validation studies. Copyright © 2013 American Institute of Chemical Engineers.

  17. Pathogenicity of bloodstream and cerebrospinal fluid forms of ...

    African Journals Online (AJOL)

    However, it is not clear whether bloodstream forms (BSF) of T.b.rhodesiense differ in biological characteristics from the cerebrospinal fluid (CSF) forms. The present study was carried out to compare the pathogenicity of CSF and BSF of T.b. rhodesiense parasites in Swiss white mice following intraperitoneal inoculation with ...

  18. Fluid transport due to nonlinear fluid-structure interaction

    DEFF Research Database (Denmark)

    Jensen, Jakob Søndergaard

    1997-01-01

    This work considers nonlinear fluid-structure interaction for a vibrating pipe containing fluid. Transverse pipe vibrations will force the fluid to move relative to the pipe creating unidirectional fluid flow towards the pipe end. The fluid flow induced affects the damping and the stiffness...... of the pipe. The behavior of the system in response to lateral resonant base excitation is analysed numerically and by the use of a perturbation method (multiple scales). Exciting the pipe in the fundamental mode of vibration seems to be most effective for transferring energy from the shaker to the fluid......, whereas higher modes of vibration can be used to transport fluid with pipe vibrations of smaller amplitude. The effect of the nonlinear geometrical terms is analysed and these terms are shown to affect the response for higher modes of vibration. Experimental investigations show good agreement...

  19. Effects of biocompatible coating of nanoparticles on acoustics property of the magnetic fluid

    International Nuclear Information System (INIS)

    Jozefczak, A.; Skumiel, A.; Labowski, M.

    2005-01-01

    Potential medical applications of ferromagnetic fluids whose nanoparticles are coated with biological substances, has stimulated the search for magnetic fluids of new properties. In this study the effects of double biocompatible coating of ferromagnetic nanoparticles on the properties of the ferrofluid subjected to an external magnetic field have been studied by the ultrasound method. The ultrasound wave absorption coefficient values measured have proved a good structural stability of dextran and polyethylene glycol magnetic fluids with its particles covered with two surfactant layers

  20. Supercritical fluid reverse micelle separation

    Science.gov (United States)

    Fulton, J.L.; Smith, R.D.

    1993-11-30

    A method of separating solute material from a polar fluid in a first polar fluid phase is provided. The method comprises combining a polar fluid, a second fluid that is a gas at standard temperature and pressure and has a critical density, and a surfactant. The solute material is dissolved in the polar fluid to define the first polar fluid phase. The combined polar and second fluids, surfactant, and solute material dissolved in the polar fluid is maintained under near critical or supercritical temperature and pressure conditions such that the density of the second fluid exceeds the critical density thereof. In this way, a reverse micelle system defining a reverse micelle solvent is formed which comprises a continuous phase in the second fluid and a plurality of reverse micelles dispersed in the continuous phase. The solute material is dissolved in the polar fluid and is in chemical equilibrium with the reverse micelles. The first polar fluid phase and the continuous phase are immiscible. The reverse micelles each comprise a dynamic aggregate of surfactant molecules surrounding a core of the polar fluid. The reverse micelle solvent has a polar fluid-to-surfactant molar ratio W, which can vary over a range having a maximum ratio W[sub o] that determines the maximum size of the reverse micelles. The maximum ratio W[sub o] of the reverse micelle solvent is then varied, and the solute material from the first polar fluid phase is transported into the reverse micelles in the continuous phase at an extraction efficiency determined by the critical or supercritical conditions. 27 figures.

  1. Supercritical fluid reverse micelle separation

    Science.gov (United States)

    Fulton, John L.; Smith, Richard D.

    1993-01-01

    A method of separating solute material from a polar fluid in a first polar fluid phase is provided. The method comprises combining a polar fluid, a second fluid that is a gas at standard temperature and pressure and has a critical density, and a surfactant. The solute material is dissolved in the polar fluid to define the first polar fluid phase. The combined polar and second fluids, surfactant, and solute material dissolved in the polar fluid is maintained under near critical or supercritical temperature and pressure conditions such that the density of the second fluid exceeds the critical density thereof. In this way, a reverse micelle system defining a reverse micelle solvent is formed which comprises a continuous phase in the second fluid and a plurality of reverse micelles dispersed in the continuous phase. The solute material is dissolved in the polar fluid and is in chemical equilibrium with the reverse micelles. The first polar fluid phase and the continuous phase are immiscible. The reverse micelles each comprise a dynamic aggregate of surfactant molecules surrounding a core of the polar fluid. The reverse micelle solvent has a polar fluid-to-surfactant molar ratio W, which can vary over a range having a maximum ratio W.sub.o that determines the maximum size of the reverse micelles. The maximum ratio W.sub.o of the reverse micelle solvent is then varied, and the solute material from the first polar fluid phase is transported into the reverse micelles in the continuous phase at an extraction efficiency determined by the critical or supercritical conditions.

  2. Hazards of organic working fluids

    International Nuclear Information System (INIS)

    Silberstein, S.

    1977-08-01

    We present several brief reviews on working fluids proposed for use in organic Rankine and bi-phase bottoming cycles. There are several general problems with many organic working fluids: flammability, toxicity, and a tendency to leak through seals. Besides, two of the proposed working fluids are to be used at temperatures above the manufacturer's maximum recommended temperature, and one is to be used in a way different from its customary usage. It may, in some cases, be more profitable to first seek alternative working fluids before committing large amounts of time and money to research projects on unsafe working fluids

  3. Heat transfer fluids containing nanoparticles

    Science.gov (United States)

    Singh, Dileep; Routbort, Jules; Routbort, A.J.; Yu, Wenhua; Timofeeva, Elena; Smith, David S.; France, David M.

    2016-05-17

    A nanofluid of a base heat transfer fluid and a plurality of ceramic nanoparticles suspended throughout the base heat transfer fluid applicable to commercial and industrial heat transfer applications. The nanofluid is stable, non-reactive and exhibits enhanced heat transfer properties relative to the base heat transfer fluid, with only minimal increases in pumping power required relative to the base heat transfer fluid. In a particular embodiment, the plurality of ceramic nanoparticles comprise silicon carbide and the base heat transfer fluid comprises water and water and ethylene glycol mixtures.

  4. Hazards of organic working fluids

    Energy Technology Data Exchange (ETDEWEB)

    Silberstein, S

    1977-08-01

    We present several brief reviews on working fluids proposed for use in organic Rankine and bi-phase bottoming cycles. There are several general problems with many organic working fluids: flammability, toxicity, and a tendency to leak through seals. Besides, two of the proposed working fluids are to be used at temperatures above the manufacturer's maximum recommended temperature, and one is to be used in a way different from its customary usage. It may, in some cases, be more profitable to first seek alternative working fluids before committing large amounts of time and money to research projects on unsafe working fluids.

  5. Plane waves in noncommutative fluids

    Energy Technology Data Exchange (ETDEWEB)

    Abdalla, M.C.B., E-mail: mabdalla@ift.unesp.br [Instituto de Física Teórica, UNESP, Universidade Estadual Paulista, Rua Dr. Bento Teobaldo Ferraz 271, Bloco 2, Barra-Funda, Caixa Postal 70532-2, 01156-970, São Paulo, SP (Brazil); Holender, L., E-mail: holender@ufrrj.br [Grupo de Física Teórica e Matemática Física, Departamento de Física, Universidade Federal Rural do Rio de Janeiro (UFRRJ), Cx. Postal 23851, BR 465 Km 7, 23890-000 Seropédica, RJ (Brazil); Santos, M.A., E-mail: masantos@cce.ufes.br [Departamento de Física e Química, Universidade Federal do Espírito Santo (UFES), Avenida Fernando Ferarri S/N, Goiabeiras, 29060-900 Vitória, ES (Brazil); Vancea, I.V., E-mail: ionvancea@ufrrj.br [Grupo de Física Teórica e Matemática Física, Departamento de Física, Universidade Federal Rural do Rio de Janeiro (UFRRJ), Cx. Postal 23851, BR 465 Km 7, 23890-000 Seropédica, RJ (Brazil)

    2013-08-01

    We study the dynamics of the noncommutative fluid in the Snyder space perturbatively at the first order in powers of the noncommutative parameter. The linearized noncommutative fluid dynamics is described by a system of coupled linear partial differential equations in which the variables are the fluid density and the fluid potentials. We show that these equations admit a set of solutions that are monochromatic plane waves for the fluid density and two of the potentials and a linear function for the third potential. The energy–momentum tensor of the plane waves is calculated.

  6. New valve with remote control and dismantling for polluting and dangerous fluid

    International Nuclear Information System (INIS)

    Villepreux, Robert.

    1980-01-01

    This invention relates to a valve for use in systems carrying polluting, corrosive or dangerous fluids requiring the use of biological protection. The facilities concerned are those in which fluids, mainly polluting, corrosive or dangerous liquids requiring the use of various types of biological protection, are handled. This is particularly so for nuclear installations in which the equipment is surrounded by protective shields which stop the radiation and prevent radioactive gases and aerosols from spreading [fr

  7. Characterization of Non-Newtonian Fluids for Environmental Applications

    Science.gov (United States)

    Espinoza, I.; Hauswirth, S.; Cerda, C. C.; Sadeghi, S.

    2017-12-01

    Non-Newtonian fluids are fluids that exhibit viscosity changes with time, stress, or changing shear rates. This distinctive quality is advantageous to a number of applications, such as hydraulic fracturing and contaminant remediation. The use of non-Newtonian fluids in contaminant remediation has recently increased as a method of improving delivery of chemical oxidants and surfactants in hard-to-reach, low permeability zones within the subsurface. As the application of these fluids continues to increase, a need to improve upon the basic understanding of non-Newtonian fluid rheology becomes increasingly important. This study investigates the characteristics of guar gum and xanthan gum, two common non-Newtonian polymers, and how factors such as composition, preparation method, and chemical and biological degradation impact the rheology of the fluids. Because the polymers are semi-hydrophobic, preparation of solutions requires blending, heating, pre-dissolution in alcohol, addition of surfactant, or stirring for extended time periods. Additionally, fluids are commonly filtered to remove undissolved material and gels, and subsequently stored under a variety of conditions. We investigated the effect of these processes on the fluids' rheology by producing solutions at a range of concentrations with a variety of preparation and storage methods. The rheological properties of the solutions were then measured over a period of months with a rotational rheometer. The experimental data were fit to standard rheological models, and the parameters of these models were used to quantitatively assess the effect of chemical composition, physical processing, and storage on the fluid rheology. The results of this study provide an improved basis with which to predict physical, chemical, and temporal alterations of guar and xanthan gum rheology, and thereby allow for improved design of experimental, modeling, and field applications utilizing non-Newtonian fluids.

  8. Biological biomaterials

    Energy Technology Data Exchange (ETDEWEB)

    Jorge-Herrero, E. [Servicio de Cirugia Experimental. Clinica Puerta de Hierro, Madrid (Spain)

    1997-05-01

    There are a number of situations in which substances of biological origin are employed as biomaterials. Most of them are macromolecules derived from isolated connective tissue or the connective tissue itself in membrane form, in both cases, the tissue can be used in its natural form or be chemically treated. In other cases, certain blood vessels can be chemically pretreated and used as vascular prostheses. Proteins such as albumin, collagen and fibrinogen are employed to coat vascular prostheses. Certain polysaccharides have also been tested for use in controlled drug release systems. Likewise, a number of tissues, such as dura mater, bovine pericardium, procine valves and human valves, are used in the preparation of cardiac prostheses. We also use veins from animals or humans in arterial replacement. In none of these cases are the tissues employed dissimilar to the native tissues as they have been chemically modified, becoming a new bio material with different physical and biochemical properties. In short, we find that natural products are being utilized as biomaterials and must be considered as such; thus, it is necessary to study both their chemicobiological and physicomechanical properties. In the present report, we review the current applications, problems and future prospects of some of these biological biomaterials. (Author) 84 refs.

  9. Fluid-structure interaction and biomedical applications

    CERN Document Server

    Galdi, Giovanni; Nečasová, Šárka

    2014-01-01

    This book presents, in a methodical way, updated and comprehensive descriptions and analyses of some of the most relevant problems in the context of fluid-structure interaction (FSI). Generally speaking, FSI is among the most popular and intriguing problems in applied sciences and includes industrial as well as biological applications. Various fundamental aspects of FSI are addressed from different perspectives, with a focus on biomedical applications. More specifically, the book presents a mathematical analysis of basic questions like the well-posedness of the relevant initial and boundary value problems, as well as the modeling and the numerical simulation of a number of fundamental phenomena related to human biology. These latter research topics include blood flow in arteries and veins, blood coagulation and speech modeling. We believe that the variety of the topics discussed, along with the different approaches used to address and solve the corresponding problems, will help readers to develop a more holis...

  10. Magnetic power piston fluid compressor

    Science.gov (United States)

    Gasser, Max G. (Inventor)

    1994-01-01

    A compressor with no moving parts in the traditional sense having a housing having an inlet end allowing a low pressure fluid to enter and an outlet end allowing a high pressure fluid to exit is described. Within the compressor housing is at least one compression stage to increase the pressure of the fluid within the housing. The compression stage has a quantity of magnetic powder within the housing, is supported by a screen that allows passage of the fluid, and a coil for selectively providing a magnetic field across the magnetic powder such that when the magnetic field is not present the individual particles of the powder are separated allowing the fluid to flow through the powder and when the magnetic field is present the individual particles of the powder pack together causing the powder mass to expand preventing the fluid from flowing through the powder and causing a pressure pulse to compress the fluid.

  11. Local order variations in confined hard-sphere fluids.

    Science.gov (United States)

    Nygård, Kim; Sarman, Sten; Kjellander, Roland

    2013-10-28

    Pair distributions of fluids confined between two surfaces at close distance are of fundamental importance for a variety of physical, chemical, and biological phenomena, such as interactions between macromolecules in solution, surface forces, and diffusion in narrow pores. However, in contrast to bulk fluids, properties of inhomogeneous fluids are seldom studied at the pair-distribution level. Motivated by recent experimental advances in determining anisotropic structure factors of confined fluids, we analyze theoretically the underlying anisotropic pair distributions of the archetypical hard-sphere fluid confined between two parallel hard surfaces using first-principles statistical mechanics of inhomogeneous fluids. For this purpose, we introduce an experimentally accessible ensemble-averaged local density correlation function and study its behavior as a function of confining slit width. Upon increasing the distance between the confining surfaces, we observe an alternating sequence of strongly anisotropic versus more isotropic local order. The latter is due to packing frustration of the spherical particles. This observation highlights the importance of studying inhomogeneous fluids at the pair-distribution level.

  12. FLUID- THERMODYNAMIC AND TRANSPORT PROPERTIES OF FLUIDS (IBM PC VERSION)

    Science.gov (United States)

    Fessler, T. E.

    1994-01-01

    The accurate computation of the thermodynamic and transport properties of fluids is a necessity for many engineering calculations. The FLUID program was developed to calculate the thermodynamic and transport properties of pure fluids in both the liquid and gas phases. Fluid properties are calculated using a simple gas model, empirical corrections, and an efficient numerical interpolation scheme. FLUID produces results that are in very good agreement with measured values, while being much faster than older more complex programs developed for the same purpose. A Van der Waals equation of state model is used to obtain approximate state values. These values are corrected for real-gas effects by model correction factors obtained from tables based on experimental data. These tables also accurately compensate for the special circumstances which arise whenever phase conditions occur. Viscosity and thermal conductivity values are computed directly from tables. Interpolation within tables is based on Lagrange's three point formula. A set of tables must be generated for each fluid implemented. FLUID currently contains tables for nine fluids including dry air and steam. The user can add tables for any fluid for which adequate thermal property data is available. The FLUID routine is structured so that it may easily be incorporated into engineering programs. The IBM 360 version of FLUID was developed in 1977. It is written in FORTRAN IV and has been implemented on an IBM 360 with a central memory requirement of approximately 222K of 8 bit bytes. The IBM PC version of FLUID is written in Microsoft FORTRAN 77 and has been implemented on an IBM PC with a memory requirement of 128K of 8 bit bytes. The IBM PC version of FLUID was developed in 1986.

  13. FLUID- THERMODYNAMIC AND TRANSPORT PROPERTIES OF FLUIDS (IBM VERSION)

    Science.gov (United States)

    Fessler, T. E.

    1994-01-01

    The accurate computation of the thermodynamic and transport properties of fluids is a necessity for many engineering calculations. The FLUID program was developed to calculate the thermodynamic and transport properties of pure fluids in both the liquid and gas phases. Fluid properties are calculated using a simple gas model, empirical corrections, and an efficient numerical interpolation scheme. FLUID produces results that are in very good agreement with measured values, while being much faster than older more complex programs developed for the same purpose. A Van der Waals equation of state model is used to obtain approximate state values. These values are corrected for real-gas effects by model correction factors obtained from tables based on experimental data. These tables also accurately compensate for the special circumstances which arise whenever phase conditions occur. Viscosity and thermal conductivity values are computed directly from tables. Interpolation within tables is based on Lagrange's three point formula. A set of tables must be generated for each fluid implemented. FLUID currently contains tables for nine fluids including dry air and steam. The user can add tables for any fluid for which adequate thermal property data is available. The FLUID routine is structured so that it may easily be incorporated into engineering programs. The IBM 360 version of FLUID was developed in 1977. It is written in FORTRAN IV and has been implemented on an IBM 360 with a central memory requirement of approximately 222K of 8 bit bytes. The IBM PC version of FLUID is written in Microsoft FORTRAN 77 and has been implemented on an IBM PC with a memory requirement of 128K of 8 bit bytes. The IBM PC version of FLUID was developed in 1986.

  14. Acoustic concentration of particles in fluid flow

    Science.gov (United States)

    Ward, Michael D.; Kaduchak, Gregory

    2010-11-23

    An apparatus for acoustic concentration of particles in a fluid flow includes a substantially acoustically transparent membrane and a vibration generator that define a fluid flow path therebetween. The fluid flow path is in fluid communication with a fluid source and a fluid outlet and the vibration generator is disposed adjacent the fluid flow path and is capable of producing an acoustic field in the fluid flow path. The acoustic field produces at least one pressure minima in the fluid flow path at a predetermined location within the fluid flow path and forces predetermined particles in the fluid flow path to the at least one pressure minima.

  15. Acoustic concentration of particles in fluid flow

    Science.gov (United States)

    Ward, Michael W.; Kaduchak, Gregory

    2017-08-15

    Disclosed herein is a acoustic concentration of particles in a fluid flow that includes a substantially acoustically transparent membrane and a vibration generator that define a fluid flow path therebetween. The fluid flow path is in fluid communication with a fluid source and a fluid outlet and the vibration generator is disposed adjacent the fluid flow path and is capable of producing an acoustic field in the fluid flow path. The acoustic field produces at least one pressure minima in the fluid flow path at a predetermined location within the fluid flow path and forces predetermined particles in the fluid flow path to the at least one pressure minima.

  16. Reliability of fluid systems

    Directory of Open Access Journals (Sweden)

    Kopáček Jaroslav

    2016-01-01

    Full Text Available This paper focuses on the importance of detection reliability, especially in complex fluid systems for demanding production technology. The initial criterion for assessing the reliability is the failure of object (element, which is seen as a random variable and their data (values can be processed using by the mathematical methods of theory probability and statistics. They are defined the basic indicators of reliability and their applications in calculations of serial, parallel and backed-up systems. For illustration, there are calculation examples of indicators of reliability for various elements of the system and for the selected pneumatic circuit.

  17. Essential Computational Fluid Dynamics

    CERN Document Server

    Zikanov, Oleg

    2011-01-01

    This book serves as a complete and self-contained introduction to the principles of Computational Fluid Dynamic (CFD) analysis. It is deliberately short (at approximately 300 pages) and can be used as a text for the first part of the course of applied CFD followed by a software tutorial. The main objectives of this non-traditional format are: 1) To introduce and explain, using simple examples where possible, the principles and methods of CFD analysis and to demystify the `black box’ of a CFD software tool, and 2) To provide a basic understanding of how CFD problems are set and

  18. Transport Coefficients of Fluids

    CERN Document Server

    Eu, Byung Chan

    2006-01-01

    Until recently the formal statistical mechanical approach offered no practicable method for computing the transport coefficients of liquids, and so most practitioners had to resort to empirical fitting formulas. This has now changed, as demonstrated in this innovative monograph. The author presents and applies new methods based on statistical mechanics for calculating the transport coefficients of simple and complex liquids over wide ranges of density and temperature. These molecular theories enable the transport coefficients to be calculated in terms of equilibrium thermodynamic properties, and the results are shown to account satisfactorily for experimental observations, including even the non-Newtonian behavior of fluids far from equilibrium.

  19. Biological effects

    International Nuclear Information System (INIS)

    Trott, K.R.

    1973-01-01

    Following an introduction into the field of cellular radiation effect considering the most important experimental results, the biological significance of the colony formation ability is brought out. The inactivation concept of stem cells does not only prove to be good, according to the present results, in the interpretation of the pathogenesis of acute radiation effects on moult tissue, it also enables chronicle radiation injuries to be interpreted through changes in the fibrous part of the organs. Radiation therapy of tumours can also be explained to a large extent by the radiation effect on the unlimited reproductiveness of tumour cells. The more or less similar dose effect curves for healthy and tumour tissue in practice lead to intermittent irradiation. The dependence of the intermittent doses and intervals on factors such as Elkind recovery, synchronisation, redistribution, reoxygenation, repopulation and regeneration are reviewed. (ORU/LH) [de

  20. Scanning Probe Microscope-Based Fluid Dispensing

    Directory of Open Access Journals (Sweden)

    Murali Krishna Ghatkesar

    2014-10-01

    Full Text Available Advances in micro and nano fabrication technologies have enabled fabrication of smaller and more sensitive devices for applications not only in solid-state physics but also in medicine and biology. The demand for devices that can precisely transport material, specifically fluids are continuously increasing. Therefore, integration of various technologies with numerous functionalities in one single device is important. Scanning probe microscope (SPM is one such device that has evolved from atomic force microscope for imaging to a variety of microscopes by integrating different physical and chemical mechanisms. In this article, we review a particular class of SPM devices that are suited for fluid dispensing. We review their fabrication methods, fluid-pumping mechanisms, real-time monitoring of dispensing, physics of dispensing, and droplet characterization. Some of the examples where these probes have already been applied are also described. Finally, we conclude with an outlook and future scope for these devices where femtolitre or smaller volumes of liquid handling are needed.

  1. From biological membranes to biomimetic model membranes

    Directory of Open Access Journals (Sweden)

    Eeman, M.

    2010-01-01

    Full Text Available Biological membranes play an essential role in the cellular protection as well as in the control and the transport of nutrients. Many mechanisms such as molecular recognition, enzymatic catalysis, cellular adhesion and membrane fusion take place into the biological membranes. In 1972, Singer et al. provided a membrane model, called fluid mosaic model, in which each leaflet of the bilayer is formed by a homogeneous environment of lipids in a fluid state including globular assembling of proteins and glycoproteins. Since its conception in 1972, many developments were brought to this model in terms of composition and molecular organization. The main development of the fluid mosaic model was made by Simons et al. (1997 and Brown et al. (1997 who suggested that membrane lipids are organized into lateral microdomains (or lipid rafts with a specific composition and a molecular dynamic that are different to the composition and the dynamic of the surrounding liquid crystalline phase. The discovery of a phase separation in the plane of the membrane has induced an explosion in the research efforts related to the biology of cell membranes but also in the development of new technologies for the study of these biological systems. Due to the high complexity of biological membranes and in order to investigate the biological processes that occur on the membrane surface or within the membrane lipid bilayer, a large number of studies are performed using biomimicking model membranes. This paper aims at revisiting the fundamental properties of biological membranes in terms of membrane composition, membrane dynamic and molecular organization, as well as at describing the most common biomimicking models that are frequently used for investigating biological processes such as membrane fusion, membrane trafficking, pore formation as well as membrane interactions at a molecular level.

  2. Oral Fluid vs. Urine Analysis to Monitor Synthetic Cannabinoids and Classic Drugs Recent Exposure.

    Science.gov (United States)

    Blandino, Vincent; Wetzel, Jillian; Kim, Jiyoung; Haxhi, Petrit; Curtis, Richard; Concheiro, Marta

    2017-01-01

    Urine is a common biological sample to monitor recent drug exposure, and oral fluid is an alternative matrix of increasing interest in clinical and forensic toxicology. Limited data are available about oral fluid vs. urine drug disposition, especially for synthetic cannabinoids. To compare urine and oral fluid as biological matrices to monitor recent drug exposure among HIV-infected homeless individuals. Seventy matched urine and oral fluid samples were collected from 13 participants. Cannabis, amphetamines, benzodiazepines, cocaine and opiates were analyzed in urine by the enzyme-multipliedimmunoassay- technique and in oral fluid by liquid chromatography tandem mass spectrometry (LCMSMS). Eleven synthetic cannabinoids were analyzed in urine and in oral fluid by LC-MSMS. Five oral fluid samples were positive for AB-FUBINACA. In urine, 4 samples tested positive for synthetic cannabinoids PB-22, 5-Fluoro-PB-22, AB-FUBINACA, and metabolites UR-144 5-pentanoic acid and UR-144 4-hydroxypentyl. In only one case, oral fluid and urine results matched, both specimens being AB-FUBINACA positive. For cannabis, 40 samples tested positive in urine and 30 in oral fluid (85.7% match). For cocaine, 37 urine and 52 oral fluid samples were positive (75.7% match). Twenty-four urine samples were positive for opiates, and 25 in oral fluid (81.4% match). For benzodiazepines, 23 samples were positive in urine and 25 in oral fluid (85.7% match). These results offer new information about drugs disposition between urine and oral fluid. Oral fluid is a good alternative matrix to urine for monitoring cannabis, cocaine, opiates and benzodiazepines recent use; however, synthetic cannabinoids showed mixed results. Copyright© Bentham Science Publishers; For any queries, please email at epub@benthamscience.org.

  3. Geophysical fluid dynamics: whence, whither and why?

    Science.gov (United States)

    Vallis, Geoffrey K

    2016-08-01

    This article discusses the role of geophysical fluid dynamics (GFD) in understanding the natural environment, and in particular the dynamics of atmospheres and oceans on Earth and elsewhere. GFD, as usually understood, is a branch of the geosciences that deals with fluid dynamics and that, by tradition, seeks to extract the bare essence of a phenomenon, omitting detail where possible. The geosciences in general deal with complex interacting systems and in some ways resemble condensed matter physics or aspects of biology, where we seek explanations of phenomena at a higher level than simply directly calculating the interactions of all the constituent parts. That is, we try to develop theories or make simple models of the behaviour of the system as a whole. However, these days in many geophysical systems of interest, we can also obtain information for how the system behaves by almost direct numerical simulation from the governing equations. The numerical model itself then explicitly predicts the emergent phenomena-the Gulf Stream, for example-something that is still usually impossible in biology or condensed matter physics. Such simulations, as manifested, for example, in complicated general circulation models, have in some ways been extremely successful and one may reasonably now ask whether understanding a complex geophysical system is necessary for predicting it. In what follows we discuss such issues and the roles that GFD has played in the past and will play in the future.

  4. Solitary waves in fluids

    CERN Document Server

    Grimshaw, RHJ

    2007-01-01

    After the initial observation by John Scott Russell of a solitary wave in a canal, his insightful laboratory experiments and the subsequent theoretical work of Boussinesq, Rayleigh and Korteweg and de Vries, interest in solitary waves in fluids lapsed until the mid 1960's with the seminal paper of Zabusky and Kruskal describing the discovery of the soliton. This was followed by the rapid development of the theory of solitons and integrable systems. At the same time came the realization that solitary waves occur naturally in many physical systems, and play a fundamental role in many circumstances. The aim of this text is to describe the role that soliton theory plays in fluids in several contexts. After an historical introduction, the book is divided five chapters covering the basic theory of the Korteweg-de Vries equation, and the subsequent application to free-surface solitary waves in water to internal solitary waves in the coastal ocean and the atmospheric boundary layer, solitary waves in rotating flows, ...

  5. Creating biological nanomaterials using synthetic biology.

    Science.gov (United States)

    Rice, MaryJoe K; Ruder, Warren C

    2014-02-01

    Synthetic biology is a new discipline that combines science and engineering approaches to precisely control biological networks. These signaling networks are especially important in fields such as biomedicine and biochemical engineering. Additionally, biological networks can also be critical to the production of naturally occurring biological nanomaterials, and as a result, synthetic biology holds tremendous potential in creating new materials. This review introduces the field of synthetic biology, discusses how biological systems naturally produce materials, and then presents examples and strategies for incorporating synthetic biology approaches in the development of new materials. In particular, strategies for using synthetic biology to produce both organic and inorganic nanomaterials are discussed. Ultimately, synthetic biology holds the potential to dramatically impact biological materials science with significant potential applications in medical systems.

  6. Creating biological nanomaterials using synthetic biology

    International Nuclear Information System (INIS)

    Rice, MaryJoe K; Ruder, Warren C

    2014-01-01

    Synthetic biology is a new discipline that combines science and engineering approaches to precisely control biological networks. These signaling networks are especially important in fields such as biomedicine and biochemical engineering. Additionally, biological networks can also be critical to the production of naturally occurring biological nanomaterials, and as a result, synthetic biology holds tremendous potential in creating new materials. This review introduces the field of synthetic biology, discusses how biological systems naturally produce materials, and then presents examples and strategies for incorporating synthetic biology approaches in the development of new materials. In particular, strategies for using synthetic biology to produce both organic and inorganic nanomaterials are discussed. Ultimately, synthetic biology holds the potential to dramatically impact biological materials science with significant potential applications in medical systems. (review)

  7. Estudo comparativo das características fluidodinâmicas de próteses valvulares biológicas de pericárdio bovino de perfil alto e baixo Comparative study of fluid dynamic characteristics in high and low biological prosthetic heart valves from bovine pericardium

    Directory of Open Access Journals (Sweden)

    Aron J. P Andrade

    1989-12-01

    Full Text Available O comportamento fluidodinâmico e a vida útil média de uma prótese valvular cardíaca são características muito importantes na escolha do modelo de prótese a ser implantada em um determinado paciente. Por esse motivo, foi realizado um estudo comparativo entre as válvulas biológicas de perfil alto e baixo, para se verificarem possíveis alterações na vida média, gradiente de pressão e refluxo, causadas pela diminuição do perfil dessas próteses. Com o auxílio de um duplicador de pulso, foram analisadas cinco próteses de perfil alto e cinco de perfil baixo, todas tamanho 29, fabricadas no Instituto Dante Pazzanese de Cardiologia (IDPC. Mantendo-se a freqüência de batimentos em 100 bpm e a diferença de pressão em 1000 mmHg, verificou-se que a vida útil média da válvula de perfil baixo permaneceu equivalente à de perfil alto. Em outro equipamento, denominado simulador cardíaco, as próteses foram submetidas a condições semelhantes às condições fisiológicas de funcionamento para uma freqüência cardíaca de 75 bpm. Os resultados mostraram que o volume de retorno necessário para fechamento (refluxo, nas válvulas de perfil baixo, é menor do que nas de perfil alto. Isso traz um melhor aproveitamento do efeito de bombeamento do coração. As perdas de carga das válvulas foram comparadas através dos gradientes máximos de pressão visibilizados com a sobreposição dos sinais de pressão. Observou-se que as válvulas de perfil baixo oferecem menos resistência ao fluxo; assim, quando são implantadas, possibilitam uma passagem mais livre e desobstruída do sangue.The fluid dynamic performance and lifetime of a prosthetic heart valve are one of the most important characteristics to determine the choice of what prosthesis must be applied to a patient. Because of this, two different biological prosthetic heart valves profiles (one high profile and other low profile were studied, to verify possible alterations of working

  8. The 1H NMR profile of healthy dog cerebrospinal fluid.

    Directory of Open Access Journals (Sweden)

    Mihai Musteata

    Full Text Available The availability of data for reference values in cerebrospinal fluid for healthy humans is limited due to obvious practical and ethical issues. The variability of reported values for metabolites in human cerebrospinal fluid is quite large. Dogs present great similarities with humans, including in cases of central nervous system pathologies. The paper presents the first study on healthy dog cerebrospinal fluid metabolomic profile using (1H NMR spectroscopy. A number of 13 metabolites have been identified and quantified from cerebrospinal fluid collected from a group of 10 mix breed healthy dogs. The biological variability as resulting from the relative standard deviation of the physiological concentrations of the identified metabolites had a mean of 18.20% (range between 9.3% and 44.8%. The reported concentrations for metabolites may be used as normal reference values. The homogeneity of the obtained results and the low biologic variability show that the (1H NMR analysis of the dog's cerebrospinal fluid is reliable in designing and interpreting clinical and therapeutic trials in dogs with central nervous system pathologies.

  9. [Fluid therapy in acute pancreatitis].

    Science.gov (United States)

    de-Madaria, Enrique

    2013-12-01

    Severe acute pancreatitis (AP) is associated with an increased need for fluids due to fluid sequestration and, in the most severe cases, with decreased peripheral vascular tone. For several decades, clinical practice guidelines have recommended aggressive fluid therapy to improve the prognosis of AP. This recommendation is based on theoretical models, animal studies, and retrospective studies in humans. Recent studies suggest that aggressive fluid administration in all patients with AP could have a neutral or harmful effect. Fluid therapy based on Ringer's lactate could improve the course of the disease, although further studies are needed to confirm this possibility. Most patients with AP do not require invasive monitoring of hemodynamic parameters to guide fluid therapy administration. Moreover, the ability of these parameters to improve prognosis has not been demonstrated. Copyright © 2013 Elsevier España, S.L. and AEEH y AEG. All rights reserved.

  10. Fluid mechanics fundamentals and applications

    CERN Document Server

    Cengel, Yunus

    2013-01-01

    Cengel and Cimbala's Fluid Mechanics Fundamentals and Applications, communicates directly with tomorrow's engineers in a simple yet precise manner. The text covers the basic principles and equations of fluid mechanics in the context of numerous and diverse real-world engineering examples. The text helps students develop an intuitive understanding of fluid mechanics by emphasizing the physics, using figures, numerous photographs and visual aids to reinforce the physics. The highly visual approach enhances the learning of Fluid mechanics by students. This text distinguishes itself from others by the way the material is presented - in a progressive order from simple to more difficult, building each chapter upon foundations laid down in previous chapters. In this way, even the traditionally challenging aspects of fluid mechanics can be learned effectively. McGraw-Hill is also proud to offer ConnectPlus powered by Maple with the third edition of Cengel/Cimbabla, Fluid Mechanics. This innovative and powerful new sy...

  11. Supercritical fluids processing: emerging opportunities

    International Nuclear Information System (INIS)

    Kovaly, K.A.

    1985-01-01

    This publication on the emerging opportunities of supercritical fluids processing reveals the latest research findings and development trends in this field. These findings and development trends are highlighted, and the results of applications of technology to the business of supercritical fluids are reported. Applications of supercritical fluids to chemical intermediates, environmental applications, chemical reactions, food and biochemistry processing, and fuels processing are discussed in some detail

  12. Chemokines in tumor proximal fluids.

    Science.gov (United States)

    Kotyza, Jaromir

    2017-03-01

    Chemokines are chemotactic cytokines produced by leukocytes and other types of cells including tumor cells. Their action is determined by the expression of cognate receptors and subsequent signaling in target cells, followed by the modulation of cytoskeletal proteins and the induction of other responses. In tumors, chemokines produced by neoplastic/stroma cells control the leukocyte infiltrate influencing tumor growth and progression. Tumor cells also express functional chemokine receptors responding to chemokine signals, promoting cell survival, proliferation and metastasis formation. Chemokines may be detected in serum of cancer patients, but due to the paracrine nature of these molecules, more significant concentrations are found in the tumor adjacent, non-vascular fluids, collectively called tumor proximal fluids. This review summarizes the expression of CC and CXC chemokines in these fluids, namely in interstitial fluid, pleural, ascitic, and cyst fluids, but also in urine, saliva, cerebrospinal fluid, cervical secretions and bronchoalveolar lavage fluid. Most comparative clinical studies reveal increased chemokine levels in high-grade tumor proximal fluids rather than in low-grade tumors and benign conditions, indicating shorter survival periods. The data confirm peritumoral fluid chemokines as sensitive diagnostic and prognostic markers, as well as offer support for chemokines and their receptors as potential targets for antitumor therapy.

  13. The fluid dynamics of climate

    CERN Document Server

    Palazzi, Elisa; Fraedrich, Klaus

    2016-01-01

    This volume provides an overview of the fluid aspects of the climate system, focusing on basic aspects as well as recent research developments. It will bring together contributions from diverse fields of the physical, mathematical and engineering sciences. The volume will be useful to doctorate students, postdocs and researchers working on different aspects of atmospheric, oceanic and environmental fluid dynamics. It will also be of interest to researchers interested in quantitatively understanding how fluid dynamics can be applied to the climate system, and to climate scientists willing to gain a deeper insight into the fluid mechanics underlying climate processes.

  14. CISM Course on Rotating Fluids

    CERN Document Server

    1992-01-01

    The volume presents a comprehensive overview of rotation effects on fluid behavior, emphasizing non-linear processes. The subject is introduced by giving a range of examples of rotating fluids encountered in geophysics and engineering. This is then followed by a discussion of the relevant scales and parameters of rotating flow, and an introduction to geostrophic balance and vorticity concepts. There are few books on rotating fluids and this volume is, therefore, a welcome addition. It is the first volume which contains a unified view of turbulence in rotating fluids, instability and vortex dynamics. Some aspects of wave motions covered here are not found elsewhere.

  15. Magnetoviscous model fluids

    CERN Document Server

    Kröger, M; Hess, S

    2003-01-01

    We review, apply and compare diverse approaches to the theoretical understanding of the dynamical and rheological behaviour of ferrofluids and magnetorheological (MR) fluids subject to external magnetic and flow fields. Simple models are introduced which are directly solvable by nonequilibrium Brownian or molecular dynamics computer simulation. In particular, the numerical results for ferrofluids quantify the domain of validity of uniaxial alignment of magnetic moments (in and) out of equilibrium. A Fokker-Planck equation for the dynamics of the magnetic moments - corresponding to the Brownian dynamics approach - and its implications are analysed under this approximation. The basic approach considers the effect of external fields on the dynamics of ellipsoid shaped permanent ferromagnetic domains (aggregates), whose size should depend on the strength of flow and magnetic field, the magnetic interaction parameter and concentration (or packing fraction). Results from analytic calculations and from simulation ar...

  16. Fluid Mechanics of Taste

    Science.gov (United States)

    Noel, Alexis; Bhatia, Nitesh; Carter, Taren; Hu, David

    2015-11-01

    Saliva plays a key role in digestion, speech and tactile sensation. Lack of saliva, also known as dry mouth syndrome, increases risk of tooth decay and alters sense of taste; nearly 10% of the general population suffer from this syndrome. In this experimental study, we investigate the spreading of water drops on wet and dry tongues of pigs and cows. We find that drops spread faster on a wet tongue than a dry tongue. We rationalize the spreading rate by consideration of the tongue microstructure, such as as papillae, in promoting wicking. By investigating how tongue microstructure affects spreading of fluids, we may begin to how understand taste receptors are activated by eating and drinking.

  17. Spin and Madelung fluid

    International Nuclear Information System (INIS)

    Salesi, G.

    1995-07-01

    Starting from the Pauli current the decomposition of the non-relativistic local velocity has been obtained in two parts (in the ordinary tensorial language): one parallel and the other orthogonal to the impulse. The former is recognized to be the classical part, that is, the center-of-mass (CM) velocity, and the latter the quantum one, that is, the velocity of the motion in the CM frame (namely, the internal spin motion or Zitterbewegung). Inserting this complete, composite expression of the velocity into the kinetic energy term of the classical non-relativistic (i.e. Newtonian) Lagrangian, the author straightforwardly get the appearance of the so called quantum potential associates as it is known, to the Madelung fluid. In such a way, the quantum mechanical behaviour of particles appears to be strictly correlated to the existence of spin and Zitterbewegung

  18. Fluid dynamics and vibration of tube banks in fluid flow

    International Nuclear Information System (INIS)

    Zukauskas, A.; Ulinskas, R.; Katinas, V.

    1988-01-01

    This work presents results derived in fluid dynamics, hydraulic drag and flow-induced vibrations within transverse and yawed tube banks. The studies encompass banks of smooth, rough and finned tubes at Reynolds numbers from 1 to 2x10/sup 6/. Highlighted in the text are fluid dynamic parameters of tube banks measured at inter-tube spaces and tube surfaces

  19. Dynamic fluid loss characteristics of foam fracturing fluids

    Energy Technology Data Exchange (ETDEWEB)

    Harris, P.C.

    1982-09-01

    Dynamic fluid loss measurements were conducted on core samples ranging in permeability between 0.02 to 140 md. These tests were run to measure the effect of several parameters on the foam fluid loss coefficients. The parameters tested were: core permeability, gel concentration in the liquid phase, foam quality, temperature, core length and differential test pressure. The type of foam that is used in most conventional fracturing treatments is a wall building fluid. Although this foam has excellent inherent fluid loss properties, the fluid loss values reported in this paper more closely resemble those of conventional fracturing fluids than reported earlier. These values have been used in the successful design of field fracturing treatments. These data support the mechanism of two phase flow in porous media suggested by Holm. The fluid passing through the cores was rich in liquid phase with composition proportional to the viscosity of the liquid phase. The broad range of fluid loss coefficients for foam calculated in these tests are intermediate in value to those reported in similar tests by Blauer and Kohlhaas, who obtained lower values, and King, who obtained higher values.

  20. Thermophysical properties of supercritical fluids and fluid mixtures

    International Nuclear Information System (INIS)

    Sengers, J.V.

    1989-08-01

    The purpose of the research is to extend the theory of critical phenomena in fluids and fluid mixtures to obtain scientifically based equations that include the crossover from the asymptotic singular behavior of the thermophysical properties close to the critical point to the regular behavior of these properties far away from the critical point

  1. Osteoarthritis screening using Raman spectroscopy of dried human synovial fluid drops

    Science.gov (United States)

    Esmonde-White, Karen A.; Mandair, Gurjit S.; Esmonde-White, Francis W. L.; Raaii, Farhang; Roessler, Blake J.; Morris, Michael D.

    2009-02-01

    We describe the use of Raman spectroscopy to investigate synovial fluid drops deposited onto fused silica microscope slides. This spectral information can be used to identify chemical changes in synovial fluid associated with osteoarthritis (OA) damage to knee joints. The chemical composition of synovial fluid is predominately proteins (enzymes, cytokines, or collagen fragments), glycosaminoglycans, and a mixture of minor components such as inorganic phosphate crystals. During osteoarthritis, the chemical, viscoelastic and biological properties of synovial fluid are altered. A pilot study was conducted to determine if Raman spectra of synovial fluid correlated with radiological scoring of knee joint damage. After informed consent, synovial fluid was drawn and x-rays were collected from the knee joints of 40 patients. Raman spectra and microscope images were obtained from the dried synovial fluid drops using a Raman microprobe and indicate a coarse separation of synovial fluid components. Individual protein signatures could not be identified; Raman spectra were useful as a general marker of overall protein content and secondary structure. Band intensity ratios used to describe protein and glycosaminoglycan structure were used in synovial fluid spectra. Band intensity ratios of Raman spectra indicate that there is less ordered protein secondary structure in synovial fluid from the damage group. Combination of drop deposition with Raman spectroscopy is a powerful approach to examining synovial fluid for the purposes of assessing osteoarthritis damage.

  2. Intraoperative fluid therapy in neonates

    African Journals Online (AJOL)

    The evidence base for the administration of intraoperative fluids in neonates is poor and extrapolated from adults and children. Differences from adults and children in physiology and anatomy of neonates inform our practice. Keywords: fluid ..... compromise lung function and wound healing. The EGL develops early in ...

  3. Applied Fluid Mechanics. Lecture Notes.

    Science.gov (United States)

    Gregg, Newton D.

    This set of lecture notes is used as a supplemental text for the teaching of fluid dynamics, as one component of a thermodynamics course for engineering technologists. The major text for the course covered basic fluids concepts such as pressure, mass flow, and specific weight. The objective of this document was to present additional fluids…

  4. Viscoelastic Fluid-Structure Interactions

    Science.gov (United States)

    Dey, Anita; Rothstein, Jonathan; Modarres-Sadeghi, Yahya

    2015-11-01

    When a flexible object such as an elastic sheet is placed perpendicular to the flow of a Newtonian fluid, the structure can oscillate due to the shedding of separated vortices at high Reynolds numbers. If the same flexible object is placed in non-Newtonian flows, however, the structure's response is still unknown. Unlike Newtonian fluids, the flow of viscoelastic fluids can become unstable at infinitesimal Reynolds numbers due to a purely elastic flow instability. In this talk, we will discuss the fluid-structure interaction between a wormlike micelle solution at high Weissenberg number and a flexible elastic sheet in cross flow. Elastic flow instabilities have been observed for wormlike micelle solutions in a number of flows. Here we will study what happens when elastic flow instabilities occur in the vicinity of a thin flexible polymer sheet. We will show that the time varying fluid forces exerted on the structure can grow large enough to cause a structural motion which can in turn feed back into the flow to modify the flow instability. The static and dynamic responses of the flexible sheet will be presented for a series of flexible sheets oriented at different angles to the flow direction, for varying fluid flow rates, and for varying fluid compositions and properties. In addition, measurements of velocity profiles and flow-induced birefringence will be presented in order to quantify the time variation of the flow field and the state of stress in the fluid.

  5. Fluid simulation for computer graphics

    CERN Document Server

    Bridson, Robert

    2008-01-01

    Animating fluids like water, smoke, and fire using physics-based simulation is increasingly important in visual effects, in particular in movies, like The Day After Tomorrow, and in computer games. This book provides a practical introduction to fluid simulation for graphics. The focus is on animating fully three-dimensional incompressible flow, from understanding the math and the algorithms to the actual implementation.

  6. Materials processing using supercritical fluids

    Directory of Open Access Journals (Sweden)

    Orlović Aleksandar M.

    2005-01-01

    Full Text Available One of the most interesting areas of supercritical fluids applications is the processing of novel materials. These new materials are designed to meet specific requirements and to make possible new applications in Pharmaceuticals design, heterogeneous catalysis, micro- and nano-particles with unique structures, special insulating materials, super capacitors and other special technical materials. Two distinct possibilities to apply supercritical fluids in processing of materials: synthesis of materials in supercritical fluid environment and/or further processing of already obtained materials with the help of supercritical fluids. By adjusting synthesis parameters the properties of supercritical fluids can be significantly altered which further results in the materials with different structures. Unique materials can be also obtained by conducting synthesis in quite specific environments like reversed micelles. This paper is mainly devoted to processing of previously synthesized materials which are further processed using supercritical fluids. Several new methods have been developed to produce micro- and nano-particles with the use of supercritical fluids. The following methods: rapid expansion of supercritical solutions (RESS supercritical anti-solvent (SAS, materials synthesis under supercritical conditions and encapsulation and coating using supercritical fluids were recently developed.

  7. Bioengineering fluid mechanics

    CERN Document Server

    Hung, Tin-kan

    2013-01-01

    This book highlights the basic concepts and equations for bioengineering flow processes. Physical concepts and meanings are emphasized while rigorous derivations are simplified, making it easier for self learning on some biological and medical flow processes. The well known Bernoulli equation in hydraulics is extended for pulsating flows, peristaltic flows and cardiac pumping. The dimensional analysis, model law and dimensionless equations can be related to computational models and experimental observations. The velocity vector imaging stored in echocardiograms can be used to analyze the pumping characteristics of the ventricular contraction. New topics included oxygen transport in membrane oxygenator and micro mixing of blood flow in capillary channels.

  8. Performance Testing of Cutting Fluids

    DEFF Research Database (Denmark)

    Belluco, Walter

    The importance of cutting fluid performance testing has increased with documentation requirements of new cutting fluid formulations based on more sustainable products, as well as cutting with minimum quantity of lubrication and dry cutting. Two sub-problems have to be solved: i) which machining...... tests feature repeatability, reproducibility and sensitivity to cutting fluids, and ii) to what extent results of one test ensure relevance to a wider set of machining situations. The present work is aimed at assessing the range of validity of the different testing methods, investigating correlation...... within the whole range of operations, materials, cutting fluids, operating conditions, etc. Cutting fluid performance was evaluated in turning, drilling, reaming and tapping, and with respect to tool life, cutting forces, chip formation and product quality (dimensional accuracy and surface integrity...

  9. Fluid Dynamics of Bottle Filling

    Science.gov (United States)

    McGough, Patrick; Gao, Haijing; Appathurai, Santosh; Basaran, Osman

    2011-11-01

    Filling of bottles is a widely practiced operation in a large number of industries. Well known examples include filling of ``large'' bottles with shampoos and cleaners in the household products and beauty care industries and filling of ``small'' bottles in the pharmaceutical industry. Some bottle filling operations have recently drawn much attention from the fluid mechanics community because of the occurrence of a multitude of complex flow regimes, transitions, and instabilities such as mounding and coiling that occur as a bottle is filled with a fluid. In this talk, we present a primarily computational study of the fluid dynamical challenges that can arise during the rapid filling of bottles. Given the diversity of fluids used in filling applications, we consider four representative classes of fluids that exhibit Newtonian, shear-thinning, viscoelastic, and yield-stress rheologies. The equations governing the dynamics of bottle filling are solved either in their full 3D but axisymmetric form or using the slender-jet approximation.

  10. Fluid simulation with articulated bodies.

    Science.gov (United States)

    Kwatra, Nipun; Wojtan, Chris; Carlson, Mark; Essa, Irfan; Mucha, Peter J; Turk, Greg

    2010-01-01

    We present an algorithm for creating realistic animations of characters that are swimming through fluids. Our approach combines dynamic simulation with data-driven kinematic motions (motion capture data) to produce realistic animation in a fluid. The interaction of the articulated body with the fluid is performed by incorporating joint constraints with rigid animation and by extending a solid/fluid coupling method to handle articulated chains. Our solver takes as input the current state of the simulation and calculates the angular and linear accelerations of the connected bodies needed to match a particular motion sequence for the articulated body. These accelerations are used to estimate the forces and torques that are then applied to each joint. Based on this approach, we demonstrate simulated swimming results for a variety of different strokes, including crawl, backstroke, breaststroke, and butterfly. The ability to have articulated bodies interact with fluids also allows us to generate simulations of simple water creatures that are driven by simple controllers.

  11. Revisiting the Landau fluid closure.

    Science.gov (United States)

    Hunana, P.; Zank, G. P.; Webb, G. M.; Adhikari, L.

    2017-12-01

    Advanced fluid models that are much closer to the full kinetic description than the usual magnetohydrodynamic description are a very useful tool for studying astrophysical plasmas and for interpreting solar wind observational data. The development of advanced fluid models that contain certain kinetic effects is complicated and has attracted much attention over the past years. Here we focus on fluid models that incorporate the simplest possible forms of Landau damping, derived from linear kinetic theory expanded about a leading-order (gyrotropic) bi-Maxwellian distribution function f_0, under the approximation that the perturbed distribution function f_1 is gyrotropic as well. Specifically, we focus on various Pade approximants to the usual plasma response function (and to the plasma dispersion function) and examine possibilities that lead to a closure of the linear kinetic hierarchy of fluid moments. We present re-examination of the simplest Landau fluid closures.

  12. Fluid Mechanics of Inhalant Siphon Flows

    Science.gov (United States)

    True, A. C.; Crimaldi, J. P.

    2016-02-01

    Inhalant siphon and suction flows are ubiquitous in marine ecosystems. From biological flows in filter-feeding benthic bivalves and predation by planktivorous fishes, to engineered flows in water samplers and production of hydrodynamic stimuli for laboratory assays, inhalant siphon flows span much of the laminar range (Reynolds number 0.01 - 2,000) and fundamentally influence many transport and exchange processes. Direct numerical simulations (DNS) of inhalant siphon flows with varying Reynolds numbers and geometries have informed design and construction of an index of refraction-matched flow facility (mineral oil, borosilicate glass tubing) in which we are employing particle image velocimetry (PIV) to quantify transient and steady-state flow fields outside and inside the siphon tube. Varying siphon diameter, flow rate, and extraction height allows us to evaluate effects of Reynolds number and siphon geometry on local hydrodynamics. This complementary experimental and numerical modeling investigation of siphon flow hydrodynamics was motivated recently by a colleague whose biologically inspired numerical modeling of inhalant siphons using a boundary condition of constant volumetric outflow (as opposed to the classically assumed uniform inlet velocity profile) revealed nontrivial departures from idealized flows: inviscid potential flows (i.e. point sink) and pipe flows (the classical pipe entry problem), particularly in the low Reynolds number regime. Reduced entrance lengths, larger radial inflows, and modifications to fluid capture zones seen numerically at low Reynolds number are being tested experimentally and may have important implications for both biological and engineered siphons.

  13. Heating production fluids in a wellbore

    Science.gov (United States)

    Orrego, Yamila; Jankowski, Todd A.

    2016-07-12

    A method for heating a production fluid in a wellbore. The method can include heating, using a packer fluid, a working fluid flowing through a first medium disposed in a first section of the wellbore, where the first medium transfers heat from the packer fluid to the working fluid. The method can also include circulating the working fluid into a second section of the wellbore through a second medium, where the second medium transfers heat from the working fluid to the production fluid. The method can further include returning the working fluid to the first section of the wellbore through the first medium.

  14. Stability of plant virus-based nanocarriers in gastrointestinal fluids.

    Science.gov (United States)

    Berardi, Alberto; Evans, David J; Baldelli Bombelli, Francesca; Lomonossoff, George P

    2018-01-25

    Cowpea mosaic virus (CPMV) is a plant virus which is being extensively investigated as a drug delivery and vaccine nanocarrier for parenteral administration. However, to date little is known about the suitability of plant-based nanocarriers for oral delivery. In this study, the colloidal (i.e. aggregation), physical (i.e. denaturation) and chemical (i.e. digestion of the polypeptides) stability of CPMV and its empty virus-like particles (eVLPs) in conditions resembling the gastrointestinal fluids were evaluated. The nanoparticles were incubated in various simulated gastric and intestinal fluids and in pig gastric and intestinal fluids. CPMV and eVLPs had similar stabilities. In simulated gastric media, they were stable at pH ≥ 2.5. At lower pH destabilisation of the particle structure occurred, which, in turn, rendered the polypeptides extremely sensitive to pepsin digestion. However, both CPMV and eVLPs were stable in simulated intestinal fluids, in pig gastric fluids and in pig intestinal fluids. Thus CPMV, despite being a protein-based nanoparticle, was much more resistant to the harsh GI conditions than soluble proteins. Remarkably, both CPMV and eVLPs incubated in pig gastric and intestinal fluids were not subject to protein adsorption, with no formation of a detectable protein corona. The lack of a protein corona on CPMV and eVLP surfaces in GI fluids would imply that, if orally administered, these nanoparticles could maintain their native surface characteristics; thus, their biological interactions would remain predictable and unchanged. In summary, CPMV and eVLPs can be considered promising nanocarriers for applications requiring oral delivery, given their chemical, physical and colloidal stability and lack of protein adsorption from the environment in most of the tested conditions.

  15. Tracing Geothermal Fluids

    Energy Technology Data Exchange (ETDEWEB)

    Michael C. Adams; Greg Nash

    2004-03-01

    Geothermal water must be injected back into the reservoir after it has been used for power production. Injection is critical in maximizing the power production and lifetime of the reservoir. To use injectate effectively the direction and velocity of the injected water must be known or inferred. This information can be obtained by using chemical tracers to track the subsurface flow paths of the injected fluid. Tracers are chemical compounds that are added to the water as it is injected back into the reservoir. The hot production water is monitored for the presence of this tracer using the most sensitive analytic methods that are economically feasible. The amount and concentration pattern of the tracer revealed by this monitoring can be used to evaluate how effective the injection strategy is. However, the tracers must have properties that suite the environment that they will be used in. This requires careful consideration and testing of the tracer properties. In previous and parallel investigations we have developed tracers that are suitable from tracing liquid water. In this investigation, we developed tracers that can be used for steam and mixed water/steam environments. This work will improve the efficiency of injection management in geothermal fields, lowering the cost of energy production and increasing the power output of these systems.

  16. Computational fluid dynamic applications

    Energy Technology Data Exchange (ETDEWEB)

    Chang, S.-L.; Lottes, S. A.; Zhou, C. Q.

    2000-04-03

    The rapid advancement of computational capability including speed and memory size has prompted the wide use of computational fluid dynamics (CFD) codes to simulate complex flow systems. CFD simulations are used to study the operating problems encountered in system, to evaluate the impacts of operation/design parameters on the performance of a system, and to investigate novel design concepts. CFD codes are generally developed based on the conservation laws of mass, momentum, and energy that govern the characteristics of a flow. The governing equations are simplified and discretized for a selected computational grid system. Numerical methods are selected to simplify and calculate approximate flow properties. For turbulent, reacting, and multiphase flow systems the complex processes relating to these aspects of the flow, i.e., turbulent diffusion, combustion kinetics, interfacial drag and heat and mass transfer, etc., are described in mathematical models, based on a combination of fundamental physics and empirical data, that are incorporated into the code. CFD simulation has been applied to a large variety of practical and industrial scale flow systems.

  17. Sixth Microgravity Fluid Physics and Transport Phenomena Conference Abstracts

    Science.gov (United States)

    Singh, Bhim (Compiler)

    2002-01-01

    The Sixth Microgravity Fluid Physics and Transport Phenomena Conference provides the scientific community the opportunity to view the current scope of the Microgravity Fluid Physics and Transport Phenomena Program, current research opportunities, and plans for the near future. The conference focuses not only on fundamental research but also on applications of this knowledge towards enabling future space exploration missions. A whole session dedicated to biological fluid physics shows increased emphasis that the program has placed on interdisciplinary research. The conference includes invited plenary talks, technical paper presentations, poster presentations, and exhibits. This TM is a compilation of abstracts of the papers and the posters presented at the conference. Web-based proceedings, including the charts used by the presenters, will be posted on the web shortly after the conference.

  18. Biological effects of radiation

    International Nuclear Information System (INIS)

    2013-01-01

    This fourth chapter presents: cell structure and metabolism; radiation interaction with biological tissues; steps of the production of biological effect of radiation; radiosensitivity of tissues; classification of biological effects; reversibility, transmissivity and influence factors; pre-natal biological effects; biological effects in therapy and syndrome of acute irradiation

  19. Hydrodynamic instabilities in miscible fluids

    Science.gov (United States)

    Truzzolillo, Domenico; Cipelletti, Luca

    2018-01-01

    Hydrodynamic instabilities in miscible fluids are ubiquitous, from natural phenomena up to geological scales, to industrial and technological applications, where they represent the only way to control and promote mixing at low Reynolds numbers, well below the transition from laminar to turbulent flow. As for immiscible fluids, the onset of hydrodynamic instabilities in miscible fluids is directly related to the physics of their interfaces. The focus of this review is therefore on the general mechanisms driving the growth of disturbances at the boundary between miscible fluids, under a variety of forcing conditions. In the absence of a regularizing mechanism, these disturbances would grow indefinitely. For immiscible fluids, interfacial tension provides such a regularizing mechanism, because of the energy cost associated to the creation of new interface by a growing disturbance. For miscible fluids, however, the very existence of interfacial stresses that mimic an effective surface tension is debated. Other mechanisms, however, may also be relevant, such as viscous dissipation. We shall review the stabilizing mechanisms that control the most common hydrodynamic instabilities, highlighting those cases for which the lack of an effective interfacial tension poses deep conceptual problems in the mathematical formulation of a linear stability analysis. Finally, we provide a short overview on the ongoing research on the effective, out of equilibrium interfacial tension between miscible fluids.

  20. Hydrodynamic instabilities in miscible fluids.

    Science.gov (United States)

    Truzzolillo, Domenico; Cipelletti, Luca

    2018-01-24

    Hydrodynamic instabilities in miscible fluids are ubiquitous, from natural phenomena up to geological scales, to industrial and technological applications, where they represent the only way to control and promote mixing at low Reynolds numbers, well below the transition from laminar to turbulent flow. As for immiscible fluids, the onset of hydrodynamic instabilities in miscible fluids is directly related to the physics of their interfaces. The focus of this review is therefore on the general mechanisms driving the growth of disturbances at the boundary between miscible fluids, under a variety of forcing conditions. In the absence of a regularizing mechanism, these disturbances would grow indefinitely. For immiscible fluids, interfacial tension provides such a regularizing mechanism, because of the energy cost associated to the creation of new interface by a growing disturbance. For miscible fluids, however, the very existence of interfacial stresses that mimic an effective surface tension is debated. Other mechanisms, however, may also be relevant, such as viscous dissipation. We shall review the stabilizing mechanisms that control the most common hydrodynamic instabilities, highlighting those cases for which the lack of an effective interfacial tension poses deep conceptual problems in the mathematical formulation of a linear stability analysis. Finally, we provide a short overview on the ongoing research on the effective, out of equilibrium interfacial tension between miscible fluids.

  1. Noncommutative geometry and fluid dynamics

    International Nuclear Information System (INIS)

    Das, Praloy; Ghosh, Subir

    2016-01-01

    In the present paper we have developed a Non-Commutative (NC) generalization of perfect fluid model from first principles, in a Hamiltonian framework. The noncommutativity is introduced at the Lagrangian (particle) coordinate space brackets and the induced NC fluid bracket algebra for the Eulerian (fluid) field variables is derived. Together with a Hamiltonian this NC algebra generates the generalized fluid dynamics that satisfies exact local conservation laws for mass and energy, thereby maintaining mass and energy conservation. However, nontrivial NC correction terms appear in the charge and energy fluxes. Other non-relativistic spacetime symmetries of the NC fluid are also discussed in detail. This constitutes the study of kinematics and dynamics of NC fluid. In the second part we construct an extension of the Friedmann-Robertson-Walker (FRW) cosmological model based on the NC fluid dynamics presented here. We outline the way in which NC effects generate cosmological perturbations bringing about anisotropy and inhomogeneity in the model. We also derive a NC extended Friedmann equation. (orig.)

  2. Effect of tibial plateau fracture on lubrication function and composition of synovial fluid.

    Science.gov (United States)

    Ballard, Brooke L; Antonacci, Jennifer M; Temple-Wong, Michele M; Hui, Alexander Y; Schumacher, Barbara L; Bugbee, William D; Schwartz, Alexandra K; Girard, Paul J; Sah, Robert L

    2012-05-16

    Intra-articular fractures may hasten posttraumatic arthritis in patients who are typically too active and too young for joint replacement. Current orthopaedic treatment principles, including recreating anatomic alignment and establishing articular congruity, have not eliminated posttraumatic arthritis. Additional biomechanical and biological factors may contribute to the development of arthritis. The objective of the present study was to evaluate human synovial fluid for friction-lowering function and the concentrations of putative lubricant molecules following tibial plateau fractures. Synovial fluid specimens were obtained from the knees of eight patients (twenty-five to fifty-seven years old) with a tibial plateau fracture, with five specimens from the injured knee as plateau fracture synovial fluid and six specimens from the contralateral knee as control synovial fluid. Each specimen was centrifuged to obtain a fluid sample, separated from a cell pellet, for further analysis. For each fluid sample, the start-up (static) and steady-state (kinetic) friction coefficients in the boundary mode of lubrication were determined from a cartilage-on-cartilage biomechanical test of friction. Also, concentrations of the putative lubricants, hyaluronan and proteoglycan-4, as well as total protein, were determined for fluid samples. The group of experimental samples were obtained at a mean (and standard deviation) of 11 ± 9 days after injury from patients with a mean age of 45 ± 13 years. Start-up and kinetic friction coefficients demonstrated similar trends and dependencies. The kinetic friction coefficients for human plateau fracture synovial fluid were approximately 100% higher than those for control human synovial fluid. Hyaluronan concentrations were ninefold lower for plateau fracture synovial fluid compared with the control synovial fluid, whereas proteoglycan-4 concentrations were more than twofold higher in plateau fracture synovial fluid compared with the control

  3. Fluid Dynamics with Cryogenic Fluid Transfer in Space Project

    Data.gov (United States)

    National Aeronautics and Space Administration — During chilldown of cryogenic fluid tanks and lines, the interface between the liquid and vapor rapidly changes. Understanding these rapid changes is key...

  4. Fluid membranes can drive linear aggregation of adsorbed spherical nanoparticles.

    Science.gov (United States)

    Sarić, Anđela; Cacciuto, Angelo

    2012-03-16

    Using computer simulations, we show that lipid membranes can mediate linear aggregation of spherical nanoparticles binding to it for a wide range of biologically relevant bending rigidities. This result is in net contrast with the isotropic aggregation of nanoparticles on fluid interfaces or the expected clustering of isotropic insertions in biological membranes. We present a phase diagram indicating where linear aggregation is expected and compute explicitly the free-energy barriers associated with linear and isotropic aggregation. Finally, we provide simple scaling arguments to explain this phenomenology.

  5. Regulation of fluid flow through the mammary gland of dairy cows and its effect on milk production: a systematic review.

    Science.gov (United States)

    Cai, Jie; Wang, Diming; Liu, Jianxin

    2018-03-01

    Dairy milk consists of more than 85% water. Therefore, understanding the regulation of fluid absorption in the mammary gland is relevant to improving milk production. In recent decades, studies using different approaches, including blood flow, transmembrane fluid flow, tight junction, fluid flow of the paracellular pathway and functional mammary epithelial cell state, have been conducted aiming to investigate how mammary gland fluid absorption is regulated. However, the relationship between regulation mechanisms of fluid flow and milk production has not been studied systematically. The present review summarizes a series of key milk yield regulatory factors mediated by whole-mammary fluid flow, including milk, mammary blood flow, blood/tissue fluid-cell fluid flow and cell-alveolus fluid flow. Whole-mammary fluid flow regulates milk production by altering transporter activity, ion channels, local microcirculation-related factors, driving force of fluid transport (osmotic pressure or electrochemical gradient), cellular connection state and a cell volume sensitive mechanism. In addition, whole-mammary fluid flow plays important roles in milk synthesis and secretion. Knowledge gained from fluid flow-mediated regulatory mechanisms of the dairy mammary gland will lead to a fundamental understanding of lactation biology and will be beneficial for the improvement of dairy productivity. © 2017 Society of Chemical Industry. © 2017 Society of Chemical Industry.

  6. Boundary effect in electrorheological fluids.

    Science.gov (United States)

    Gong, X L; Yang, F; Xuan, S H; Zong, L H; Zhu, W; Jiang, W Q

    2011-12-01

    The effect of the boundary friction coefficient on the rheological properties of the electrorheological (ER) fluids in quasistatic and dynamic states is investigated by computer simulation. The relation between the shear stress and the boundary friction coefficient in quasistatic and dynamic states is discussed qualitatively and quantitatively, and the trend matches the previously reported experimental results well. The flow curves of ER fluids, under different friction coefficients, are calculated, and it is found that the friction coefficient affects the flow curves. In two dimensions, the transitions in structure corresponding to the shear stress variations are presented to understand the mechanism of ER fluids.

  7. Quantum field theory of fluids.

    Science.gov (United States)

    Gripaios, Ben; Sutherland, Dave

    2015-02-20

    The quantum theory of fields is largely based on studying perturbations around noninteracting, or free, field theories, which correspond to a collection of quantum-mechanical harmonic oscillators. The quantum theory of an ordinary fluid is "freer", in the sense that the noninteracting theory also contains an infinite collection of quantum-mechanical free particles, corresponding to vortex modes. By computing a variety of correlation functions at tree and loop level, we give evidence that a quantum perfect fluid can be consistently formulated as a low-energy, effective field theory. We speculate that the quantum behavior is radically different from both classical fluids and quantum fields.

  8. Fluid intelligence: A brief history.

    Science.gov (United States)

    Kent, Phillip

    2017-01-01

    The concept of fluid and crystallized intelligence was introduced to the psychological community approximately 75 years ago by Raymond B. Cattell, and it continues to be an area of active research and controversy. The purpose of this paper is to provide a brief overview of the origin of the concept, early efforts to define intelligence and uses of intelligence tests to address pressing social issues, and the ongoing controversies associated with fluid intelligence and the structure of intelligence. The putative neuropsychological underpinnings and neurological substrates of fluid intelligence are discussed.

  9. Molecular thermodynamics of nonideal fluids

    CERN Document Server

    Lee, Lloyd L

    2013-01-01

    Molecular Thermodynamics of Nonideal Fluids serves as an introductory presentation for engineers to the concepts and principles behind and the advances in molecular thermodynamics of nonideal fluids. The book covers related topics such as the laws of thermodynamics; entropy; its ensembles; the different properties of the ideal gas; and the structure of liquids. Also covered in the book are topics such as integral equation theories; theories for polar fluids; solution thermodynamics; and molecular dynamics. The text is recommended for engineers who would like to be familiarized with the concept

  10. Basic developments in fluid dynamics

    CERN Document Server

    Holt, Maurice

    2012-01-01

    Basic Developments in Fluid Dynamics, Volume 2 focuses on the developments, approaches, methodologies, reactions, and processes involved in fluid dynamics, including sea motion, wave interactions, and motion of spheres in a viscous fluid.The selection first offers information on inviscid cavity and wake flows and weak-interaction theory of ocean waves. Discussions focus on steady and unsteady cavity flows, radiation balance, theory of weak interactions in random fields, interactions between gravity waves and the atmosphere, and interactions within the ocean. The text then examines low Reynolds

  11. Spinning fluids in general relativity

    Science.gov (United States)

    Ray, J. R.; Smalley, L. L.

    1982-01-01

    General relativity field equations are employed to examine a continuous medium with internal spin. A variational principle formerly applied in the special relativity case is extended to the general relativity case, using a tetrad to express the spin density and the four-velocity of the fluid. An energy-momentum tensor is subsequently defined for a spinning fluid. The equations of motion of the fluid are suggested to be useful in analytical studies of galaxies, for anisotropic Bianchi universes, and for turbulent eddies.

  12. Advances in Environmental Fluid Mechanics

    CERN Document Server

    Mihailovic, Dragutin T

    2010-01-01

    Environmental fluid mechanics (EFM) is the scientific study of transport, dispersion and transformation processes in natural fluid flows on our planet Earth, from the microscale to the planetary scale. This book brings together scientists and engineers working in research institutions, universities and academia, who engage in the study of theoretical, modeling, measuring and software aspects in environmental fluid mechanics. It provides a forum for the participants, and exchanges new ideas and expertise through the presentations of up-to-date and recent overall achievements in this field.

  13. Swimming efficiency in a shear-thinning fluid

    Science.gov (United States)

    Nganguia, Herve; Pietrzyk, Kyle; Pak, On Shun

    2017-12-01

    Micro-organisms expend energy moving through complex media. While propulsion speed is an important property of locomotion, efficiency is another factor that may determine the swimming gait adopted by a micro-organism in order to locomote in an energetically favorable manner. The efficiency of swimming in a Newtonian fluid is well characterized for different biological and artificial swimmers. However, these swimmers often encounter biological fluids displaying shear-thinning viscosities. Little is known about how this nonlinear rheology influences the efficiency of locomotion. Does the shear-thinning rheology render swimming more efficient or less? How does the swimming efficiency depend on the propulsion mechanism of a swimmer and rheological properties of the surrounding shear-thinning fluid? In this work, we address these fundamental questions on the efficiency of locomotion in a shear-thinning fluid by considering the squirmer model as a general locomotion model to represent different types of swimmers. Our analysis reveals how the choice of surface velocity distribution on a squirmer may reduce or enhance the swimming efficiency. We determine optimal shear rates at which the swimming efficiency can be substantially enhanced compared with the Newtonian case. The nontrivial variations of swimming efficiency prompt questions on how micro-organisms may tune their swimming gaits to exploit the shear-thinning rheology. The findings also provide insights into how artificial swimmers should be designed to move through complex media efficiently.

  14. Influence of hydrodynamic cavitation on biological objects

    OpenAIRE

    Мальований, Мирослав Степанович; Никифоров, Володимир Валентинович; Синельніков, Олександр Дмитрович; Харламова, Олена Володимирівна; Бунько, Василь Ярославович

    2015-01-01

    Cavitation, which yet has not found a wide application in industrial technologies, is an effective method of hydro-mechanical intensification of chemical-engineering, food, pharmaceutical, biological and other processes. The effectiveness of cavitation process is enabled by cavitation crashing of the solid phase, turbulent diffusion of boundary layer of the fluid by cavitation bubbles, emergence mass transfer aspects, which are characterized by high values of mass transfer coefficients. Proce...

  15. Standardization of Thermo-Fluid Modeling in Modelica.Fluid

    Energy Technology Data Exchange (ETDEWEB)

    Franke, Rudiger; Casella, Francesco; Sielemann, Michael; Proelss, Katrin; Otter, Martin; Wetter, Michael

    2009-09-01

    This article discusses the Modelica.Fluid library that has been included in the Modelica Standard Library 3.1. Modelica.Fluid provides interfaces and basic components for the device-oriented modeling of onedimensional thermo-fluid flow in networks containing vessels, pipes, fluid machines, valves and fittings. A unique feature of Modelica.Fluid is that the component equations and the media models as well as pressure loss and heat transfer correlations are decoupled from each other. All components are implemented such that they can be used for media from the Modelica.Media library. This means that an incompressible or compressible medium, a single or a multiple substance medium with one or more phases might be used with one and the same model as long as the modeling assumptions made hold. Furthermore, trace substances are supported. Modeling assumptions can be configured globally in an outer System object. This covers in particular the initialization, uni- or bi-directional flow, and dynamic or steady-state formulation of mass, energy, and momentum balance. All assumptions can be locally refined for every component. While Modelica.Fluid contains a reasonable set of component models, the goal of the library is not to provide a comprehensive set of models, but rather to provide interfaces and best practices for the treatment of issues such as connector design and implementation of energy, mass and momentum balances. Applications from various domains are presented.

  16. Biological Potential in Serpentinizing Systems

    Science.gov (United States)

    Hoehler, Tori M.

    2016-01-01

    Generation of the microbial substrate hydrogen during serpentinization, the aqueous alteration of ultramafic rocks, has focused interest on the potential of serpentinizing systems to support biological communities or even the origin of life. However the process also generates considerable alkalinity, a challenge to life, and both pH and hydrogen concentrations vary widely across natural systems as a result of different host rock and fluid composition and differing physical and hydrogeologic conditions. Biological potential is expected to vary in concert. We examined the impact of such variability on the bioenergetics of an example metabolism, methanogenesis, using a cell-scale reactive transport model to compare rates of metabolic energy generation as a function of physicochemical environment. Potential rates vary over more than 5 orders of magnitude, including bioenergetically non-viable conditions, across the range of naturally occurring conditions. In parallel, we assayed rates of hydrogen metabolism in wells associated with the actively serpentinizing Coast Range Ophiolite, which includes conditions more alkaline and considerably less reducing than is typical of serpentinizing systems. Hydrogen metabolism is observed at pH approaching 12 but, consistent with the model predictions, biological methanogenesis is not observed.

  17. Fluid Mechanics Can Be Fun.

    Science.gov (United States)

    Blanks, Robert F.

    1979-01-01

    A humanistic approach to teaching fluid mechanics is described which minimizes lecturing, increases professor-student interaction, uses group and individual problem solving sessions, and allows for student response. (BB)

  18. Electrokinetic effects and fluid permeability

    International Nuclear Information System (INIS)

    Berryman, J.G.

    2003-01-01

    Fluid permeability of porous media depends mainly on connectivity of the pore space and two physical parameters: porosity and a pertinent length-scale parameter. Electrical imaging methods typically establish connectivity and directly measure electrical conductivity, which can then often be related to porosity by Archie's law. When electrical phase measurements are made in addition to the amplitude measurements, information about the pertinent length scale can then be obtained. Since fluid permeability controls the ability to flush unwanted fluid contaminants from the subsurface, inexpensive maps of permeability could improve planning strategies for remediation efforts. Detailed knowledge of fluid permeability is also important for oil field exploitation, where knowledge of permeability distribution in three dimensions is a common requirement for petroleum reservoir simulation and analysis, as well as for estimates on the economics of recovery

  19. Heart failure - fluids and diuretics

    Science.gov (United States)

    ... page: //medlineplus.gov/ency/patientinstructions/000112.htm Heart failure - fluids and diuretics To use the sharing features on this page, please enable JavaScript. Heart failure is a condition in which the heart is ...

  20. Thermodynamic properties of cryogenic fluids

    CERN Document Server

    Leachman, Jacob; Lemmon, Eric; Penoncello, Steven

    2017-01-01

    This update to a classic reference text provides practising engineers and scientists with accurate thermophysical property data for cryogenic fluids. The equations for fifteen important cryogenic fluids are presented in a basic format, accompanied by pressure-enthalpy and temperature-entropy charts and tables of thermodynamic properties. It begins with a chapter introducing the thermodynamic relations and functional forms for equations of state, and goes on to describe the requirements for thermodynamic property formulations, needed for the complete definition of the thermodynamic properties of a fluid. The core of the book comprises extensive data tables and charts for the most commonly-encountered cryogenic fluids. This new edition sees significant updates to the data presented for air, argon, carbon monoxide, deuterium, ethane, helium, hydrogen, krypton, nitrogen and xenon. The book supports and complements NIST’s REFPROP - an interactive database and tool for the calculation of thermodynamic propertie...

  1. Mesoscopic model for binary fluids

    Science.gov (United States)

    Echeverria, C.; Tucci, K.; Alvarez-Llamoza, O.; Orozco-Guillén, E. E.; Morales, M.; Cosenza, M. G.

    2017-10-01

    We propose a model for studying binary fluids based on the mesoscopic molecular simulation technique known as multiparticle collision, where the space and state variables are continuous, and time is discrete. We include a repulsion rule to simulate segregation processes that does not require calculation of the interaction forces between particles, so binary fluids can be described on a mesoscopic scale. The model is conceptually simple and computationally efficient; it maintains Galilean invariance and conserves the mass and energy in the system at the micro- and macro-scale, whereas momentum is conserved globally. For a wide range of temperatures and densities, the model yields results in good agreement with the known properties of binary fluids, such as the density profile, interface width, phase separation, and phase growth. We also apply the model to the study of binary fluids in crowded environments with consistent results.

  2. Closed Loop Fluid Delivery System

    Science.gov (United States)

    2014-02-28

    loop fluid delivery system (CLFDS) will integrate a vital signs monitor ( VSM ) and high speed infusion pump (Pump) to respond quickly to drops in...Interface (GUI) shows VSM data, allows the user to select from several injury types (head, uncontrolled hemorrhage, controlled hemorrhage, and three total...the bedrock for future Closed Loop Fluid System Pre-Market Approval application(s) to FDA. 6. Major Issues Clinical study testing revealed a

  3. Diamond growth in mantle fluids

    OpenAIRE

    Bureau, Hélène; Frost, Daniel J.; Bolfan-casanova, Nathalie; Leroy, Clémence; Esteve, Imène; Cordier, Patrick

    2016-01-01

    International audience; In the upper mantle, diamonds can potentially grow from various forms of media (solid, gas, fluid) with a range of compositions (e.g. graphite, C–O–H fluids, silicate or carbonate melts). Inclusions trapped in diamonds are one of the few diagnostic tools that can constrain diamond growth conditions in the Earth's mantle. In this study, inclusion-bearing diamonds have been synthesized to understand the growth conditions of natural diamonds in the upper mantle. Diamonds ...

  4. Organic compounds in hydraulic fracturing fluids and wastewaters: A review.

    Science.gov (United States)

    Luek, Jenna L; Gonsior, Michael

    2017-10-15

    High volume hydraulic fracturing (HVHF) of shale to stimulate the release of natural gas produces a large quantity of wastewater in the form of flowback fluids and produced water. These wastewaters are highly variable in their composition and contain a mixture of fracturing fluid additives, geogenic inorganic and organic substances, and transformation products. The qualitative and quantitative analyses of organic compounds identified in HVHF fluids, flowback fluids, and produced waters are reviewed here to communicate knowledge gaps that exist in the composition of HVHF wastewaters. In general, analyses of organic compounds have focused on those amenable to gas chromatography, focusing on volatile and semi-volatile oil and gas compounds. Studies of more polar and non-volatile organic compounds have been limited by a lack of knowledge of what compounds may be present as well as quantitative methods and standards available for analyzing these complex mixtures. Liquid chromatography paired with high-resolution mass spectrometry has been used to investigate a number of additives and will be a key tool to further research on transformation products that are increasingly solubilized through physical, chemical, and biological processes in situ and during environmental contamination events. Diverse treatments have been tested and applied to HVHF wastewaters but limited information has been published on the quantitative removal of individual organic compounds. This review focuses on recently published information on organic compounds identified in flowback fluids and produced waters from HVHF. Copyright © 2017 Elsevier Ltd. All rights reserved.

  5. Application of transport phenomena analysis technique to cerebrospinal fluid.

    Science.gov (United States)

    Lam, C H; Hansen, E A; Hall, W A; Hubel, A

    2013-12-01

    The study of hydrocephalus and the modeling of cerebrospinal fluid flow have proceeded in the past using mathematical analysis that was very capable of prediction phenomenonologically but not well in physiologic parameters. In this paper, the basis of fluid dynamics at the physiologic state is explained using first established equations of transport phenomenon. Then, microscopic and molecular level techniques of modeling are described using porous media theory and chemical kinetic theory and then applied to cerebrospinal fluid (CSF) dynamics. Using techniques of transport analysis allows the field of cerebrospinal fluid dynamics to approach the level of sophistication of urine and blood transport. Concepts such as intracellular and intercellular pathways, compartmentalization, and tortuosity are associated with quantifiable parameters that are relevant to the anatomy and physiology of cerebrospinal fluid transport. The engineering field of transport phenomenon is rich and steeped in architectural, aeronautical, nautical, and more recently biological history. This paper summarizes and reviews the approaches that have been taken in the field of engineering and applies it to CSF flow.

  6. Nuclear fluid dynamics and TDHF

    International Nuclear Information System (INIS)

    Koehler, H.S.

    1982-01-01

    In some previous reports a modified TDHF (Time Dependent Hartree-Fock) equation including a collision term was introduced. The collisions were included in the relaxation-time approximation familiar in classical transport theory. In plasma-physics it is often referred to as the Krook-model. The author explores the approximate nature of, and the possible computational advantage of revamping the modified TDHF-equation into fluid-equations, by truncating the moment-expansion of the Wigner-function. In the fluid-equations that are derived the mean field and the relaxation time are both maintained explicitly. The pressure tensor is allowed to be anisotropic, i.e., the fluid is viscous. Only in the limit of a very short relaxation time (approximately 10 -23 s) may the isotropic (non-viscous) approximation be acceptable. The fluid-equations are tested by comparing computed results with those obtained with the modified TDHF. It is concluded that the fluid-equations are a viable alternative. Some differences can be attributed to the neglect of the higher moments of the momentum-distribution in the fluid-equations. Others are due to other approximations necessary in the truncation. (Auth.)

  7. Fluid element in SAP IV

    International Nuclear Information System (INIS)

    Yilmaz, C.; Akkas, N.

    1979-01-01

    In previous studies a fluid element is incorporated in the widely used general purpose finite element program SAPIV. This type of problem is of interest in the design of nuclear components involving geometric complexities and nonlinearities. The elasticity matrix of a general-purpose finite element program is modified in such a way that it becomes possible to idealize fluid as a structural finite element with zero shear modulus and a given bulk modules. Using the modified version of SAPIV, several solid-fluid interactions problems are solved. The numerical solutions are compared with the available analytical solutions. They are shown to be in reasonable aggrement. It is also shown that by solving an exterior-fluid interaction problem, the pressure wave propagation in the acoustic medium can be solved with the same approach. In this study, two of the problem not studied in the previous work will be presented. These problems are namely the effects of the link elements used at solid-fluid interfaces and of the concentrated loads on the response of the fluid medium. Truss elements are used as the link elements. After these investigations, it is decided that general purpose finite element programs with slight modifications can be used in the safety analysis of nuclear reactor plants. By this procedure it is possible to handle two-dimensional plane strain and tridimensional axisymmetric problems of this type. (orig.)

  8. Physics through the 1990s: Plasmas and fluids

    International Nuclear Information System (INIS)

    1986-01-01

    This survey of plasma physics and fluid physics briefly describes present activities and recent major accomplishments. It also identifies research areas that are likely to lead to advances during the next decade. Plasma physics is divided into three major areas: general plasma physics, fusion plasma confinement and heating, and space and astrophysical plasmas. Fluid physics is treated as one topic, although it is an extremely diverse research field ranging from biological fluid dynamics to ship and aircraft performance to geological fluid dynamics. Subpanels, chosen for their technical expertise and scientific breadth, reviewed each of the four areas. The entire survey was coordinated and supervised by an Executive Committee, which is also responsible for the Executive Summary of this volume. Wherever possible, input from recent Advisory Committees was used, e.g., from the Magnetic Fusion Advisory Committee, the Space Science Board, and the Astronomy Survey Committee. This volume is organized as follows: An Introduction and Executive Summary that outlines (1) major findings and recommendations; (2) significant research accomplishments during the past decade and likely areas of future research emphasis; and (3) a brief summary of present funding levels, manpower resources, and institutional involvement; and the subpanel reports constitute Fluid Physics, General Plasma Physics, Fusion Plasma Confinement and Heating, and Space and Astrophysical Plasmas. An important conclusion of this survey is that both plasma physics and fluid physics are scientifically and intellectually well developed, and both ares are broad subdisciplines of physics. We therefore recommend that future physics surveys have separate volumes on the physics of plasmas and the physics of fluids

  9. Thermophysical properties of supercritical fluids and fluid mixtures

    International Nuclear Information System (INIS)

    Sengers, J.V.

    1991-07-01

    This research is concerned with the development of a quantitative scientific description of the thermodynamic and transport properties of supercritical and subcritical fluids and fluid mixtures. It is known that the thermophysical properties of fluids and fluid mixtures asymptotically close to the critical point satisfy scaling laws with universal critical exponents and universal scaling functions. However, the range of validity of these asymptotic scaling laws is quite small. As a consequence, the impact of the modern theory of critical phenomena on chemical engineering has been limited. On the other hand, an a priori estimate of the range of temperatures and densities, where critical fluctuations become significant, can be made on the basis of the so-called Ginzburg criterion. A recent analysis of this criterion suggests that this range is actually quite large and for a fluid like carbon dioxide can easily extend to 100 degrees or so above the critical temperature. Hence, the use of traditional engineering equations like cubic equations is not scientifically justified in a very wide range of temperatures and densities around the critical point. We have therefore embarked on a scientific approach to deal with the global effects of critical fluctuations on the thermophysical properties of fluids and fluid mixtures. For this purpose it is not sufficient to consider the asymptotic critical fluctuations but we need to deal also with the nonasymptotic critical fluctuations. The goal is to develop scientifically based questions that account for the crossover of the thermophysical properties from their asymptotic singular behavior in the near vicinity of the critical point to their regular behavior very far away from the critical point

  10. 3D Suspended Polymeric Microfluidics (SPMF3 with Flow Orthogonal to Bending (FOB for Fluid Analysis through Kinematic Viscosity

    Directory of Open Access Journals (Sweden)

    Mostapha Marzban

    2017-10-01

    Full Text Available Measuring of fluid properties such as dynamic viscosity and density has tremendous potential for various applications from physical to biological to chemical sensing. However, it is almost impossible to affect only one of these properties, as dynamic viscosity and density are coupled. Hence, this paper proposes kinematic viscosity as a comprehensive parameter which can be used to study the effect of fluid properties applicable to various fluids from Newtonian fluids, such as water, to non-Newtonian fluids, such as blood. This paper also proposes an ideal microplatform, namely polymeric suspended microfluidics (SPMF3, with flow plane orthogonal to the bending plane of the structure, along with tested results of various fluids covering a wide range of engineering applications. Kinematic viscosity, also called momentum diffusivity, considers changes in both fluid intermolecular forces and molecular inertia that define dynamic viscosity and fluid density, respectively. In this study a 3D suspended polymeric microfluidic system (SPMF3 was employed to detect changes in fluid parameters such as dynamic viscosity and density during fluid processes. Using this innovative design along with theoretical and experimental results, it is shown that, in fluids, the variations of fluid density and dynamic viscosity are not easily comprehensible due to their interconnectivity. Since any change in a fluid will affect both density and dynamic viscosity, measuring both of them is necessary to identify the fluid or process status. Finally, changes in fluid properties were analyzed using simulation and experiments. The experimental results with salt-DI water solution and milk with different fat concentrations as a colloidal fluid show that kinematic viscosity is a comprehensive parameter that can identify the fluids in a unique way using the proposed microplatform.

  11. Chaos analysis of viscoelastic chaotic flows of polymeric fluids in a micro-channel

    Energy Technology Data Exchange (ETDEWEB)

    Lim, C. P.; Lam, Y. C., E-mail: myclam@ntu.edu.sg [School of Mechanical and Aerospace Engineering, Nanyang Technological University, 639798 (Singapore); BioSystems and Micromechanics (BioSyM) IRG, Singapore-MIT Alliance for Research and Technology (SMART) Centre, 138602 (Singapore); Han, J. [BioSystems and Micromechanics (BioSyM) IRG, Singapore-MIT Alliance for Research and Technology (SMART) Centre, 138602 (Singapore); Department of Electrical Engineering and Computer Science, Massachusetts Institute of Technology, Cambridge, MA 02139 (United States); Department of Biological Engineering, Massachusetts Institute of Technology, Cambridge, MA 02139 (United States)

    2015-07-15

    Many fluids, including biological fluids such as mucus and blood, are viscoelastic. Through the introduction of chaotic flows in a micro-channel and the construction of maps of characteristic chaos parameters, differences in viscoelastic properties of these fluids can be measured. This is demonstrated by creating viscoelastic chaotic flows induced in an H-shaped micro-channel through the steady infusion of a polymeric fluid of polyethylene oxide (PEO) and another immiscible fluid (silicone oil). A protocol for chaos analysis was established and demonstrated for the analysis of the chaotic flows generated by two polymeric fluids of different molecular weight but with similar relaxation times. The flows were shown to be chaotic through the computation of their correlation dimension (D{sub 2}) and the largest Lyapunov exponent (λ{sub 1}), with D{sub 2} being fractional and λ{sub 1} being positive. Contour maps of D{sub 2} and λ{sub 1} of the respective fluids in the operating space, which is defined by the combination of polymeric fluids and silicone oil flow rates, were constructed to represent the characteristic of the chaotic flows generated. It was observed that, albeit being similar, the fluids have generally distinct characteristic maps with some similar trends. The differences in the D{sub 2} and λ{sub 1} maps are indicative of the difference in the molecular weight of the polymers in the fluids because the driving force of the viscoelastic chaotic flows is of molecular origin. This approach in constructing the characteristic maps of chaos parameters can be employed as a diagnostic tool for biological fluids and, more generally, chaotic signals.

  12. Dyneins: structure, biology and disease

    National Research Council Canada - National Science Library

    King, Stephen M

    2012-01-01

    .... From bench to bedside, Dynein: Structure, Biology and Disease offers research on fundamental cellular processes to researchers and clinicians across developmental biology, cell biology, molecular biology, biophysics, biomedicine...

  13. Learning Biology by Designing

    Science.gov (United States)

    Janssen, Fred; Waarlo, Arend Jan

    2010-01-01

    According to a century-old tradition in biological thinking, organisms can be considered as being optimally designed. In modern biology this idea still has great heuristic value. In evolutionary biology a so-called design heuristic has been formulated which provides guidance to researchers in the generation of knowledge about biological systems.…

  14. Biological conversion system

    Science.gov (United States)

    Scott, C.D.

    A system for bioconversion of organic material comprises a primary bioreactor column wherein a biological active agent (zymomonas mobilis) converts the organic material (sugar) to a product (alcohol), a rejuvenator column wherein the biological activity of said biological active agent is enhanced, and means for circulating said biological active agent between said primary bioreactor column and said rejuvenator column.

  15. [Biogeography: geography or biology?].

    Science.gov (United States)

    Kafanov, A I

    2009-01-01

    General biogeography is an interdisciplinary science, which combines geographic and biological aspects constituting two distinct research fields: biological geography and geographic biology. These fields differ in the nature of their objects of study, employ different methods and represent Earth sciences and biological sciences, respectively. It is suggested therefore that the classification codes for research fields and the state professional education standard should be revised.

  16. Thermal Stabilization of Biologics with Photoresponsive Hydrogels.

    Science.gov (United States)

    Sridhar, Balaji V; Janczy, John R; Hatlevik, Øyvind; Wolfson, Gabriel; Anseth, Kristi S; Tibbitt, Mark W

    2018-03-12

    Modern medicine, biological research, and clinical diagnostics depend on the reliable supply and storage of complex biomolecules. However, biomolecules are inherently susceptible to thermal stress and the global distribution of value-added biologics, including vaccines, biotherapeutics, and Research Use Only (RUO) proteins, requires an integrated cold chain from point of manufacture to point of use. To mitigate reliance on the cold chain, formulations have been engineered to protect biologics from thermal stress, including materials-based strategies that impart thermal stability via direct encapsulation of the molecule. While direct encapsulation has demonstrated pronounced stabilization of proteins and complex biological fluids, no solution offers thermal stability while enabling facile and on-demand release from the encapsulating material, a critical feature for broad use. Here we show that direct encapsulation within synthetic, photoresponsive hydrogels protected biologics from thermal stress and afforded user-defined release at the point of use. The poly(ethylene glycol) (PEG)-based hydrogel was formed via a bioorthogonal, click reaction in the presence of biologics without impact on biologic activity. Cleavage of the installed photolabile moiety enabled subsequent dissolution of the network with light and release of the encapsulated biologic. Hydrogel encapsulation improved stability for encapsulated enzymes commonly used in molecular biology (β-galactosidase, alkaline phosphatase, and T4 DNA ligase) following thermal stress. β-galactosidase and alkaline phosphatase were stabilized for 4 weeks at temperatures up to 60 °C, and for 60 min at 85 °C for alkaline phosphatase. T4 DNA ligase, which loses activity rapidly at moderately elevated temperatures, was protected during thermal stress of 40 °C for 24 h and 60 °C for 30 min. These data demonstrate a general method to employ reversible polymer networks as robust excipients for thermal stability of complex

  17. Destabilization and Recuperability of Oil Used in the Formulation of Concentrated Emulsions and Cutting Fluids

    OpenAIRE

    Guimarães, A. P.; Maia, D. A. S.; Araújo, R. S.; Cavalcante Jr, C. L.; de Sant’Ana, H. B.

    2010-01-01

    Lubricants known as cutting fluids are used in the metal-mechanic industry with the function of cooling and lubricating the cutting zone. These lubricants normally have a water phase, an oil phase, emulsifying agents and additives. Once the operational capacity of these fluids has ceased, either due to biological deterioration or to overabundance of contaminants, the emulsions being used must be treated in order to adequate their effluents for discharge. This study aims to evaluate the destab...

  18. Fluid Mechanics An Introduction to the Theory of Fluid Flows

    CERN Document Server

    Durst, Franz

    2008-01-01

    Advancements of fluid flow measuring techniques and of computational methods have led to new ways to treat laminar and turbulent flows. These methods are extensively used these days in research and engineering practise. This also requires new ways to teach the subject to students at higher educational institutions in an introductory manner. The book provides the knowledge to students in engineering and natural science needed to enter fluid mechanics applications in various fields. Analytical treatments are provided, based on the Navier-Stokes equations. Introductions are also given into numerical and experimental methods applied to flows. The main benefit the reader will derive from the book is a sound introduction into all aspects of fluid mechanics covering all relevant subfields.

  19. 14 CFR 25.1185 - Flammable fluids.

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Flammable fluids. 25.1185 Section 25.1185... STANDARDS: TRANSPORT CATEGORY AIRPLANES Powerplant Powerplant Fire Protection § 25.1185 Flammable fluids. (a... system containing flammable fluids or gases may be in a designated fire zone unless the fluid contained...

  20. 7 CFR 2902.41 - Metalworking fluids.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 15 2010-01-01 2010-01-01 false Metalworking fluids. 2902.41 Section 2902.41... Items § 2902.41 Metalworking fluids. (a) Definition. (1) Fluids that are designed to provide cooling... operations such as cutting, drilling, grinding, machining, and tapping. (2) Metalworking fluids for which...

  1. 14 CFR 125.153 - Flammable fluids.

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 3 2010-01-01 2010-01-01 false Flammable fluids. 125.153 Section 125.153....153 Flammable fluids. (a) No tanks or reservoirs that are a part of a system containing flammable fluids or gases may be located in designated fire zones, except where the fluid contained, the design of...

  2. Yang-Mills Magneto-Fluid Unification

    OpenAIRE

    Bambah, Bindu A.; Mahajan, Swadesh M.; Mukku, Chandrasekher

    2006-01-01

    We generalize the hybrid magneto-fluid model of a charged fluid interacting with an electromagnetic field to the dynamics of a relativistic hot fluid interacting with a non-Abelian field. The fluid itself is endowed with a non-Abelian charge and the consequences of this generalization are worked out. Applications of this formalism to the Quark Gluon Plasma are suggested.

  3. Fluid Behavior and Fluid-Solid Interactions in Nanoporous Media

    Science.gov (United States)

    Xu, H.

    2015-12-01

    Although shale oil/gas production in the US has increased exponentially, the low energy recovery is a daunting problem needed to be solved for its sustainability and continued growth, especially in light of the recent oil/gas price decline. This is apparently related to the small porosity (a few to a few hundred nm) and low permeability (10-16-10-20 m2) of tight shale formations. The fundamental question lies in the anomalous behavior of fluids in nanopores due to confinement effects, which, however, remains poorly understood. In this study, we combined experimental characterization and observations, particularly using small-angle neutron scattering (SANS), with pore-scale modeling using lattice Boltzmann method (LBM), to examine the fluid behavior and fluid-solid interactions in nanopores at reservoir conditions. Experimentally, we characterized the compositions and microstructures of a shale sample from Wolfcamp, Texas, using a variety of analytical techniques. Our analyses reveal that the shale sample is made of organic-matter (OM)-lean and OM-rich layers that exhibit different chemical and mineral compositions, and microstructural characteristics. Using the hydrostatic pressure system and gas-mixing setup we developed, in-situ SANS measurements were conducted at pressures up to 20 kpsi on shale samples imbibed with water or water-methane solutions. The obtained results indicate that capillary effect plays a significant role in fluid-nanopore interactions and the associated changes in nanopore structures vary with pore size and pressure. Computationally, we performed LBM modeling to simulate the flow behavior of methane in kerogen nanoporous structure. The correction factor, which is the ratio of apparent permeability to intrinsic permeability, was calculated. Our results show that the correction factor is always greater than one (non-continuum/non-Darcy effects) and increases with decreasing nanopore size, intrinsic permeability and pressure. Hence, the

  4. Combustion, Complex Fluids, and Fluid Physics Experiments on the ISS

    Science.gov (United States)

    Motil, Brian; Urban, David

    2012-01-01

    From the very first days of human spaceflight, NASA has been conducting experiments in space to understand the effect of weightlessness on physical and chemically reacting systems. NASA Glenn Research Center (GRC) in Cleveland, Ohio has been at the forefront of this research looking at both fundamental studies in microgravity as well as experiments targeted at reducing the risks to long duration human missions to the moon, Mars, and beyond. In the current International Space Station (ISS) era, we now have an orbiting laboratory that provides the highly desired condition of long-duration microgravity. This allows continuous and interactive research similar to Earth-based laboratories. Because of these capabilities, the ISS is an indispensible laboratory for low gravity research. NASA GRC has been actively involved in developing and operating facilities and experiments on the ISS since the beginning of a permanent human presence on November 2, 2000. As the lead Center both Combustion, Fluid Physics, and Acceleration Measurement GRC has led the successful implementation of an Acceleration Measurement systems, the Combustion Integrated Rack (CIR), the Fluids Integrated Rack (FIR) as well as the continued use of other facilities on the ISS. These facilities have supported combustion experiments in fundamental droplet combustion fire detection fire extinguishment soot phenomena flame liftoff and stability and material flammability. The fluids experiments have studied capillary flow magneto-rheological fluids colloidal systems extensional rheology pool and nucleate boiling phenomena. In this paper, we provide an overview of the experiments conducted on the ISS over the past 12 years. We also provide a look to the future development. Experiments presented in combustion include areas such as droplet combustion, gaseous diffusion flames, solid fuels, premixed flame studies, fire safety, and super critical oxidation processes. In fluid physics, experiments are discussed in

  5. The NASA Microgravity Fluid Physics Program: Knowledge for Use on Earth and Future Space Missions

    Science.gov (United States)

    Kohl, Fred J.; Singh, Bhim S.; Alexander, J. Iwan; Shaw, Nancy J.; Hill, Myron E.; Gati, Frank G.

    2002-01-01

    Building on over four decades of research and technology development related to the behavior of fluids in low gravity environments, the current NASA Microgravity Fluid Physics Program continues the quest for knowledge to further understand and design better fluids systems for use on earth and in space. The purpose of the Fluid Physics Program is to support the goals of NASA's Biological and Physical Research Enterprise which seeks to exploit the space environment to conduct research and to develop commercial opportunities, while building the vital knowledge base needed to enable efficient and effective systems for protecting and sustaining humans during extended space flights. There are currently five major research areas in the Microgravity Fluid Physics Program: complex fluids, multiphase flows and phase change, interfacial phenomena, biofluid mechanics, and dynamics and instabilities. Numerous investigations into these areas are being conducted in both ground-based laboratories and facilities and in the flight experiments program. Most of the future NASA-sponsored fluid physics and transport phenomena studies will be carried out on the International Space Station in the Fluids Integrated Rack, in the Microgravity Science Glovebox, in EXPRESS racks, and in other facilities provided by international partners. This paper will present an overview of the near- and long-term visions for NASA's Microgravity Fluid Physics Research Program and brief descriptions of hardware systems planned to achieve this research.

  6. Chlamydia trachomatis in hydrocele fluid.

    Science.gov (United States)

    Satpathy, G; Mohanty, S; Pani, S P; Panda, S K

    1997-01-01

    OBJECTIVE: To determine the presence of Chlamydia trachomatis in hydrocele fluid. METHODS: 90 male patients with hydrocele of tunica vaginalis from an endemic area for bancroftian filariasis were investigated for the presence of Chlamydia trachomatis in their hydrocele fluids. C trachomatis antigen detection tests-a direct immunofluorescence assay and an enzyme immunoassay along with polymerase chain reaction assay for amplification of a 517 bp fragment of C trachomatis endogenous plasmid-were used in this study. The patients were also tested for the presence of microfilaria in their hydrocele fluids and night blood. Histopathological examination was carried out to detect adult filarial worm in tunica vaginalis testes. RESULTS: Eight (8.88%) patients had chlamydia antigen in the hydrocele fluids; C trachomatis plasmid sequences could be amplified from five of these. Seven (7.77%) patients had microfilaria in the hydrocele fluids, three of them having adult worm in tunica vaginalis. CONCLUSION: C trachomatis infection might be associated with hydrocele in some of these patients. PMID:9582470

  7. Electrostatic correlations: from plasma to biology

    International Nuclear Information System (INIS)

    Levin, Yan

    2002-01-01

    Electrostatic correlations play an important role in physics, chemistry and biology. In plasmas they result in thermodynamic instability similar to the liquid-gas phase transition of simple molecular fluids. For charged colloidal suspensions the electrostatic correlations are responsible for screening and colloidal charge renormalization. In aqueous solutions containing multivalent counterions they can lead to charge inversion and flocculation. In biological systems the correlations account for the organization of cytoskeleton and the compaction of genetic material. In spite of their ubiquity, the true importance of electrostatic correlations has come to be fully appreciated only quite recently. In this paper, we will review the thermodynamic consequences of electrostatic correlations in a variety of systems ranging from classical plasmas to molecular biology

  8. Intermediate Physics for Medicine and Biology

    CERN Document Server

    Hobbie, Russell K

    2007-01-01

    Intended for advanced undergraduate and beginning graduate students in biophysics, physiology, medical physics, cell biology, and biomedical engineering, this wide-ranging text bridges the gap between introductory physics and its application to the life and biomedical sciences. This extensively revised and updated fourth edition reflects new developments at the burgeoning interface between physics and biomedicine. Among the many topics treated are: forces in the skeletal system; fluid flow, with examples from the circulatory system; the logistic equation; scaling; transport of neutral particles by diffusion and by solvent drag; membranes and osmosis; equipartition of energy in statistical mechanics; the chemical potential and free energy; biological magnetic fields; membranes and gated channels in membranes; linear and nonlinear feedback systems; nonlinear phenomena, including biological clocks and chaotic behavior; signal analysis, noise and stochastic resonance detection of weak signals; image formation and...

  9. Magnetohydrodynamic pump with a system for promoting flow of fluid in one direction

    Science.gov (United States)

    Lemoff, Asuncion V [Union City, CA; Lee, Abraham P [Irvine, CA

    2010-07-13

    A magnetohydrodynamic pump for pumping a fluid. The pump includes a microfluidic channel for channeling the fluid, a MHD electrode/magnet system operatively connected to the microfluidic channel, and a system for promoting flow of the fluid in one direction in the microfluidic channel. The pump has uses in the medical and biotechnology industries for blood-cell-separation equipment, biochemical assays, chemical synthesis, genetic analysis, drug screening, an array of antigen-antibody reactions, combinatorial chemistry, drug testing, medical and biological diagnostics, and combinatorial chemistry. The pump also has uses in electrochromatography, surface micromachining, laser ablation, inkjet printers, and mechanical micromilling.

  10. Sixth Microgravity Fluid Physics and Transport Phenomena Conference: Exposition Topical Areas 1-6. Volume 2

    Science.gov (United States)

    Singh, Bhim (Compiler)

    2002-01-01

    The Sixth Microgravity Fluid Physics and Transport Phenomena Conference provides the scientific community the opportunity to view the current scope of the Microgravity Fluid Physics and Transport Phenomena Program, current research opportunities, and plans for the near future. The conference focuses not only on fundamental research but also on applications of this knowledge towards enabling future space exploration missions. A whole session dedicated to biological fluid physics shows increased emphasis that the program has placed on interdisciplinary research. The conference includes invited plenary talks, technical paper presentations, poster presentations, and exhibits. This CP (conference proceeding) is a compilation of the abstracts, presentations, and posters presented at the conference.

  11. Ultrasonic techniques for fluids characterization

    CERN Document Server

    Povey, Malcolm J W

    1997-01-01

    This book is a comprehensive and practical guide to the use of ultrasonic techniques for the characterization of fluids. Focusing on ultrasonic velocimetry, the author covers the basic topics and techniques necessaryfor successful ultrasound measurements on emulsions, dispersions, multiphase media, and viscoelastic/viscoplastic materials. Advanced techniques such as scattering, particle sizing, and automation are also presented. As a handbook for industrial and scientific use, Ultrasonic Techniques for Fluids Characterization is an indispensable guide to chemists and chemical engineers using ultrasound for research or process monitoring in the chemical, food processing, pharmaceutical, cosmetic, biotechnology,and fuels industries. Key Features * Appeals to anyone using ultrasound to study fluids * Provides the first detailed description of the ultrasound profiling technique for dispersions * Describes new techniques for measuring phase transitions and nucleation, such as water/ice and oil/fat * Presents the l...

  12. Coulombic Fluids Bulk and Interfaces

    CERN Document Server

    Freyland, Werner

    2011-01-01

    Ionic liquids have attracted considerable interest in recent years. In this book the bulk and interfacial physico-chemical characteristics of various fluid systems dominated by Coulomb interactions are treated which includes molten salts, ionic liquids as well as metal-molten salt mixtures and expanded fluid metals. Of particular interest is the comparison of the different systems. Topics in the bulk phase concern the microscopic structure, the phase behaviour and critical phenomena, and the metal-nonmetal transition. Interfacial phenomena include wetting transitions, electrowetting, surface freezing, and the electrified ionic liquid/ electrode interface. With regard to the latter 2D and 3D electrochemical phase formation of metals and semi-conductors on the nanometer scale is described for a number of selected examples. The basic concepts and various experimental methods are introduced making the book suitable for both graduate students and researchers interested in Coulombic fluids.

  13. Rotational superradiance in fluid laboratories

    CERN Document Server

    Cardoso, Vitor; Richartz, Mauricio; Weinfurtner, Silke

    2016-01-01

    Rotational superradiance has been predicted theoretically decades ago, and is the chief responsible for a number of important effects and phenomenology in black hole physics. However, rotational superradiance has never been observed experimentally. Here, with the aim of probing superradiance in the lab, we investigate the behaviour of sound and surface waves in fluids resting in a circular basin at the center of which a rotating cylinder is placed. We show that with a suitable choice for the material of the cylinder, surface and sound waves are amplified. By confining the superradiant modes near the rotating cylinder, an instability sets in. Our findings are experimentally testable in existing fluid laboratories and hence offer experimental exploration and comparison of dynamical instabilities arising from rapidly rotating boundary layers in astrophysical as well as in fluid dynamical systems.

  14. Visualization of Computational Fluid Dynamics

    Science.gov (United States)

    Gerald-Yamasaki, Michael; Hultquist, Jeff; Bryson, Steve; Kenwright, David; Lane, David; Walatka, Pamela; Clucas, Jean; Watson, Velvin; Lasinski, T. A. (Technical Monitor)

    1995-01-01

    Scientific visualization serves the dual purpose of exploration and exposition of the results of numerical simulations of fluid flow. Along with the basic visualization process which transforms source data into images, there are four additional components to a complete visualization system: Source Data Processing, User Interface and Control, Presentation, and Information Management. The requirements imposed by the desired mode of operation (i.e. real-time, interactive, or batch) and the source data have their effect on each of these visualization system components. The special requirements imposed by the wide variety and size of the source data provided by the numerical simulation of fluid flow presents an enormous challenge to the visualization system designer. We describe the visualization system components including specific visualization techniques and how the mode of operation and source data requirements effect the construction of computational fluid dynamics visualization systems.

  15. Fluid control in microfluidic devices using a fluid conveyance extension and an absorbent microfluidic flow modulator.

    Science.gov (United States)

    Yuen, Po Ki

    2013-05-07

    This article presents a simple method for controlling fluid in microfluidic devices without the need for valves or pumps. A fluid conveyance extension is fluidly coupled to the enclosed outlet chamber of a microfluidic device. After a fluid is introduced into the microfluidic device and saturates the fluid conveyance extension, a fluid flow in the microfluidic device is generated by contacting an absorbent microfluidic flow modulator with the fluid conveyance extension to absorb the fluid from the fluid conveyance extension through capillary action. Since the fluid in the microfluidic device is fluidly coupled with the fluid conveyance extension and the fluid conveyance extension is fluidly coupled with the absorbent microfluidic flow modulator, the absorption rate of the absorbent microfluidic flow modulator, which is the rate at which the absorbent microfluidic flow modulator absorbs fluid, matches the fluid flow rate in the microfluidic device. Thus, the fluid flow rate in the microfluidic device is set by the absorption rate of the absorbent microfluidic flow modulator. Sheath flow and fluid switching applications are demonstrated using this simple fluid control method without the need for valves or pumps. Also, the ability to control the fluid flow rate in the microfluidic device is demonstrated using absorbent microfluidic flow modulators with various absorbent characteristics and dimensions.

  16. Removable butterfly valve, especially for polluting and/or dangerous fluids

    International Nuclear Information System (INIS)

    Garrigues, J.C.

    1984-01-01

    This invention relates to a valve for use in systems carrying polluting, corrosive or dangerous fluids requiring the use of biological protection. The facilities concerned are those in which fluids, mainly polluting, corrosive or dangerous liquids requiring the use of various types of biological protection, are handled. This is particularly so for nuclear installations in which the equipment is surrounded by protective shields which stop the radiation and prevent radioactive gases and aerosols from spreading. The invention proposes for the present valve a high-safety leaktightness system which respects the most specifications and standards and which suppresses any dead volume inside the valve [fr

  17. Nonlinear rheology of complex fluid-fluid interfaces

    NARCIS (Netherlands)

    Sagis, L.M.C.; Fischer, P.

    2014-01-01

    Fluid–fluid interfaces stabilized by proteins, protein aggregates, polymers, or colloidal particles, tend to have a complex microstructure. Their response to an applied deformation is often highly nonlinear, even at small deformation (rates). The nonlinearity of the response is a result of changes

  18. Editorial Special Issue on Fluid Mechanics and Fluid Power (FMFP ...

    Indian Academy of Sciences (India)

    Jawaharlal Nehru Centre for Advanced Scientific Research, Bangalore. Fluid mechanics touches almost all aspects of the natural and engineering ... lence which distorts electromagnetic waves; an earth scientist may simulate convection in the earth's mantle to understand plate tectonics or convection in the atmosphere to ...

  19. Sideload vanes for fluid pump

    Science.gov (United States)

    Erler, Scott R. (Inventor); Dills, Michael H. (Inventor); Rodriguez, Jose L. (Inventor); Tepool, John Eric (Inventor)

    2010-01-01

    A fluid pump assembly includes a rotatable component that can be rotated about an axis and a static vane assembly located adjacent to the rotatable component. The static vane assembly includes a circumferential surface axially spaced from the rotatable component, and one or more vanes extending from the circumferential surface toward the rotatable component. The one or more vanes are configured to produce a radial load on the rotatable component when the rotatable component is rotating about the axis and a fluid is present between the static vane assembly and the rotatable component.

  20. Wellbottom fluid implosion treatment system

    Science.gov (United States)

    Brieger, Emmet F.

    2001-01-01

    A system for inducing implosion shock forces on perforation traversing earth formations with fluid pressure where an implosion tool is selected relative to a shut in well pressure and a tubing pressure to have a large and small area piston relationship in a well tool so that at a predetermined tubing pressure the pistons move a sufficient distance to open an implosion valve which permits a sudden release of well fluid pressure into the tubing string and produces an implosion force on the perforations. A pressure gauge on the well tool records tubing pressure and well pressure as a function of time.

  1. Fluid mechanics problems and solutions

    CERN Document Server

    Spurk, Joseph H

    1997-01-01

    his collection of over 200 detailed worked exercises adds to and complements the textbook Fluid Mechanics by the same author, and illustrates the teaching material through examples. In the exercises the fundamental concepts of Fluid Mechanics are applied to obtaining the solution of diverse concrete problems, and in doing this the student's skill in the mathematical modeling of practical problems is developed. In addition, 30 challenging questions without detailed solutions have been included, and while lecturers will find these questions suitable for examinations and tests, the student himself can use them to check his understanding of the subject.

  2. Analysis of giant electrorheological fluids.

    Science.gov (United States)

    Seo, Youngwook P; Seo, Yongsok

    2013-07-15

    The yield stress dependence on electric field strength for giant electrorheological (GER) fluids over the full range of electric fields was examined using Seo's scaling function which incorporated both the polarization and the conductivity models. If a proper scaling was applied to the yield stress data to collapse them onto a single curve, the Seo's scaling function could correctly fit the yield stress behavior of GER suspensions, even at very high electric field strengths. The model predictions were also compared with recently proposed Choi et al.'s model to allow a consideration of the universal framework of ER fluids. Copyright © 2013 Elsevier Inc. All rights reserved.

  3. Fluid systems for RICH detectors

    CERN Document Server

    Ullaland, O

    2005-01-01

    The optical properties of the radiator media are of prime importance in Ring Imaging Cherenkov detectors. The main requirements for the radiator fluid are a stable refractive index and a photon absorption as low as possible. We will in this note cover some of the cleaning procedures which are required together with distillation and similar separation procedures. Thin film membranes have been introduced during the last decade. They have proven particularly interesting in separating air from some Cherenkov fluids. We will also discuss the use of molecular sieves.

  4. Microbial Metabolism in Serpentinite Fluids

    Science.gov (United States)

    Crespo-Medina, M.; Brazelton, W. J.; Twing, K. I.; Kubo, M.; Hoehler, T. M.; Schrenk, M. O.

    2013-12-01

    Serpentinization is the process in which ultramafic rocks, characteristic of the upper mantle, react with water liberating mantle carbon and reducing power to potenially support chemosynthetic microbial communities. These communities may be important mediators of carbon and energy exchange between the deep Earth and the surface biosphere. Our work focuses on the Coast Range Ophiolite Microbial Observatory (CROMO) in Northern California where subsurface fluids are accessible through a series of wells. Preliminary analyses indicate that the highly basic fluids (pH 9-12) have low microbial diversity, but there is limited knowledge about the metabolic capabilities of these communties. Metagenomic data from similar serpentine environments [1] have identified Betaproteobacteria belonging to the order Burkholderiales and Gram-positive bacteria from the order Clostridiales as key components of the serpentine microbiome. In an effort to better characterize the microbial community, metabolism, and geochemistry at CROMO, fluids from two representative wells (N08B and CSWold) were sampled during recent field campaigns. Geochemical characterization of the fluids includes measurements of dissolved gases (H2, CO, CH4), dissolved inorganic and organic carbon, volatile fatty acids, and nutrients. The wells selected can be differentiated in that N08B had higher pH (10-11), lower dissolved oxygen, and cell counts ranging from 105-106 cells mL-1 of fluid, with an abundance of the betaproteobacterium Hydrogenophaga. In contrast, fluids from CSWold have slightly lower pH (9-9.5), DO, and conductivity, as well as higher TDN and TDP. CSWold fluid is also characterized for having lower cell counts (~103 cells mL-1) and an abundance of Dethiobacter, a taxon within the phylum Clostridiales. Microcosm experiments were conducted with the purpose of monitoring carbon fixation, methanotrophy and metabolism of small organic compounds, such as acetate and formate, while tracing changes in fluid

  5. Piezooptic behavior of certain fluids

    International Nuclear Information System (INIS)

    Weiss, J.D.

    1985-01-01

    In this paper we present an analysis of pressure--volume data for certain optical fluids, which characterizes them by two parameters: their bulk moduli and the pressure derivative of their bulk moduli, both evaluated at zero pressure. We then relate their refractive-index changes to density and pressure using this analysis and the Lorentz-Lorenz equation with a density-dependent polarizability. An example of the use of such fluids in a fiber-optic pressure gauge being developed at Sandia is also discussed

  6. Effects of fluid dynamics on cleaning efficacy of supercritical fluids

    Energy Technology Data Exchange (ETDEWEB)

    Phelps, M.R.; Willcox, W.A.; Silva, L.J.; Butner, R.S.

    1993-03-01

    Pacific Northwest Laboratory (PNL) and Boeing Aerospace Company are developing a process to clean metal parts using a supercritical solvent. This work is part of an effort to address issues inhibiting the rapid commercialization of Supercritical Fluid Parts Cleaning (SFPC). PNL assembled a SFPC test stand to observe the relationship between the fluid dynamics of the system and the mass transfer of a contaminant from the surface of a contaminated metal coupon into the bulk fluid. The bench-scale test stand consists of a Berty'' autoclave modified for these tests and supporting hardware to achieve supercritical fluids parts cleaning. Three separate sets of tests were conducted using supercritical carbon dioxide. For the first two tests, a single stainless steel coupon was cleaned with organic solvents to remove surface residue, doped with a single contaminant, and then cleaned in the SFPC test stand. Contaminants studied were Dow Corning 200 fluid (dimethylpolysiloxane) and Castle/Sybron X-448 High-temperature Oil (a polybutane/mineral oil mixture). A set of 5-minute cleaning runs was conducted for each dopant at various autoclave impeller speeds. Test results from the first two sets of experiments indicate that precision cleaning for difficult-to-remove contaminants can be dramatically improved by introducing and increasing turbulence within the system. Metal coupons that had been previously doped with aircraft oil were used in a third set of tests. The coupons were placed in the SFPC test stand and subjected to different temperatures, pressures, and run times at a constant impeller speed. The cleanliness of each part was measured by Optically Stimulated Electron Emission. The third set of tests show that levels of cleanliness attained with supercritical carbon dioxide compare favorably with solvent and aqueous cleaning levels.

  7. Effects of fluid dynamics on cleaning efficacy of supercritical fluids

    Energy Technology Data Exchange (ETDEWEB)

    Phelps, M.R.; Willcox, W.A.; Silva, L.J.; Butner, R.S.

    1993-03-01

    Pacific Northwest Laboratory (PNL) and Boeing Aerospace Company are developing a process to clean metal parts using a supercritical solvent. This work is part of an effort to address issues inhibiting the rapid commercialization of Supercritical Fluid Parts Cleaning (SFPC). PNL assembled a SFPC test stand to observe the relationship between the fluid dynamics of the system and the mass transfer of a contaminant from the surface of a contaminated metal coupon into the bulk fluid. The bench-scale test stand consists of a ``Berty`` autoclave modified for these tests and supporting hardware to achieve supercritical fluids parts cleaning. Three separate sets of tests were conducted using supercritical carbon dioxide. For the first two tests, a single stainless steel coupon was cleaned with organic solvents to remove surface residue, doped with a single contaminant, and then cleaned in the SFPC test stand. Contaminants studied were Dow Corning 200 fluid (dimethylpolysiloxane) and Castle/Sybron X-448 High-temperature Oil (a polybutane/mineral oil mixture). A set of 5-minute cleaning runs was conducted for each dopant at various autoclave impeller speeds. Test results from the first two sets of experiments indicate that precision cleaning for difficult-to-remove contaminants can be dramatically improved by introducing and increasing turbulence within the system. Metal coupons that had been previously doped with aircraft oil were used in a third set of tests. The coupons were placed in the SFPC test stand and subjected to different temperatures, pressures, and run times at a constant impeller speed. The cleanliness of each part was measured by Optically Stimulated Electron Emission. The third set of tests show that levels of cleanliness attained with supercritical carbon dioxide compare favorably with solvent and aqueous cleaning levels.

  8. Fluid mechanical responses to nutrient depletion in fungi and biofilmsa)

    Science.gov (United States)

    Brenner, Michael P.

    2014-10-01

    In both fungi and bacterial biofilms, when nutrients are depleted, the organisms cannot physically migrate to find a new source, but instead must develop adaptations that allow them to survive. This paper reviews our work attempting to discover design principles for these adaptations. We develop fluid mechanical models, and aim to understand whether these suggest organizing principles for the observed morphological diversity. Determining whether a proposed organizing principle explains extant biological designs is fraught with difficulty: simply because a design principle predicts characteristics similar to an organism's morphology could just as well be accidental as revealing. In each of the two sets of examples, we adopt different strategies to develop understanding in spite of this difficulty. Within the fungal phylum Ascomycota, we use the large observed diversity of different morphological solutions to the fundamental fluid mechanical problem to measure how far each solution is from a design optimum, thereby measuring how far the extant designs deviate from the hypothesized optimum. This allows comparing different design principles to each other. For biofilms, we use engineering principles to make qualitative predictions of what types of adaptations might exist given the physicochemical properties of the repertoire of proteins that bacteria can create, and then find evidence for these adaptations in experiments. While on the surface this paper addresses the particular adaptations used by the fungal phylum Ascomycota and bacterial biofilms, we also aim to motivate discussion of different approaches to using design principles, fluid mechanical or otherwise, to rationalize observed engineering solutions in biology.

  9. PREFACE: Statistical Physics of Complex Fluids

    Science.gov (United States)

    Golestanian, R.; Khajehpour, M. R. H.; Kolahchi, M. R.; Rouhani, S.

    2005-04-01

    The field of complex fluids is a rapidly developing, highly interdisciplinary field that brings together people from a plethora of backgrounds such as mechanical engineering, chemical engineering, materials science, applied mathematics, physics, chemistry and biology. In this melting pot of science, the traditional boundaries of various scientific disciplines have been set aside. It is this very property of the field that has guaranteed its richness and prosperity since the final decade of the 20th century and into the 21st. The C3 Commission of the International Union of Pure and Applied Physics (IUPAP), which is the commission for statistical physics that organizes the international STATPHYS conferences, encourages various, more focused, satellite meetings to complement the main event. For the STATPHYS22 conference in Bangalore (July 2004), Iran was recognized by the STATPHYS22 organizers as suitable to host such a satellite meeting and the Institute for Advanced Studies in Basic Sciences (IASBS) was chosen to be the site of this meeting. It was decided to organize a meeting in the field of complex fluids, which is a fairly developed field in Iran. This international meeting, and an accompanying summer school, were intended to boost international connections for both the research groups working in Iran, and several other groups working in the Middle East, South Asia and North Africa. The meeting, entitled `Statistical Physics of Complex Fluids' was held at the Institute for Advanced Studies in Basic Sciences (IASBS) in Zanjan, Iran, from 27 June to 1 July 2004. The main topics discussed at the meeting included: biological statistical physics, wetting and microfluidics, transport in complex media, soft and granular matter, and rheology of complex fluids. At this meeting, 22 invited lectures by eminent scientists were attended by 107 participants from different countries. The poster session consisted of 45 presentations which, in addition to the main topics of the

  10. Rheology and non-Newtonian fluids

    CERN Document Server

    Irgens, Fridtjov

    2014-01-01

    This book gives a brief but thorough introduction to the fascinating subject of non-Newtonian fluids, their behavior and mechanical properties. After a brief introduction of what characterizes non-Newtonian fluids in Chapter 1 some phenomena characteristic of non-Newtonian fluids are presented in Chapter 2. The basic equations in fluid mechanics are discussed in Chapter 3. Deformation kinematics, the kinematics of shear flows, viscometric flows, and extensional flows are the topics in Chapter 4. Material functions characterizing the behavior of fluids in special flows are defined in Chapter 5. Generalized Newtonian fluids are the most common types of non-Newtonian fluids and are the subject in Chapter 6. Some linearly viscoelastic fluid models are presented in Chapter 7. In Chapter 8 the concept of tensors is utilized and advanced fluid models are introduced. The book is concluded with a variety of 26 problems. Solutions to the problems are ready for instructors.

  11. Group behaviour in physical, chemical and biological systems

    Indian Academy of Sciences (India)

    2014-03-15

    Mar 15, 2014 ... a gel; the collection of finite clusters is a sol, a complex entity that retains properties of a fluid.7 ... lowest internal energy).8 The physico-chemical approach to studying the behaviour of biological .... 12 The relative abundances of the chemical elements are explained by invoking a particular history of the ...

  12. Somatomedin activity in synovial fluid.

    Science.gov (United States)

    Coates, C L; Burwell, R G; Buttery, P J; Walker, G; Woodward, P M

    1977-01-01

    Abnormalities of synovial fluid, as a lubricant and nutrient, may have relevance to the causation of certain articular diseases. The somatomedin activity in normal synovial fluid obtained from the knee joint of the ox has been studied and compared with the activity in serum from the same animal. The porcine costal cartilage bioassay of Van den Brande and Du Caju (1974) has been used with the isotopes 35S-sulphate and 3H-thymidine. The mean potency ratio of ox synovial fluid in terms of ox serum for 35S-sulphate incorporation was 0-28 (range 0-19-0-47) and for 3H-thymidine incorporation 0-35 (range 0-21-0-63). A significant correlation was found between the somatomedin activity (as measured by 35S-sulphate incorporation) and the total protein and albumin concentrations in the ox synovial fluids and the ox sera, but there was no significant relationship between the somatomedin potency ratios and the globulin concentrations. The possible relevance of these findings to injury and disease in synovial joint is discussed. PMID:843111

  13. Computational Fluid Dynamics in Ventilation

    DEFF Research Database (Denmark)

    Nielsen, Peter V.; Allard, Francis; Awbi, Hazim B.

    2008-01-01

    Computational Fluid Dynamics in Ventilation Design is a new title in the is a new title in the REHVA guidebook series. The guidebook is written for people who need to use and discuss results based on CFD predictions, and it gives insight into the subject for those who are not used to work with CFD...

  14. Protein profiling of cerebrospinal fluid

    DEFF Research Database (Denmark)

    Simonsen, Anja H

    2012-01-01

    The cerebrospinal fluid (CSF) perfuses the brain and spinal cord. CSF contains proteins and peptides important for brain physiology and potentially also relevant for brain pathology. Hence, CSF is the perfect source to search for new biomarkers to improve diagnosis of neurological diseases as well...

  15. Free Falling in Stratified Fluids

    Science.gov (United States)

    Lam, Try; Vincent, Lionel; Kanso, Eva

    2017-11-01

    Leaves falling in air and discs falling in water are examples of unsteady descents due to complex interaction between gravitational and aerodynamic forces. Understanding these descent modes is relevant to many branches of engineering and science such as estimating the behavior of re-entry space vehicles to studying biomechanics of seed dispersion. For regularly shaped objects falling in homogenous fluids, the motion is relatively well understood. However, less is known about how density stratification of the fluid medium affects the falling behavior. Here, we experimentally investigate the descent of discs in both pure water and in stable linearly stratified fluids for Froude numbers Fr 1 and Reynolds numbers Re between 1000 -2000. We found that stable stratification (1) enhances the radial dispersion of the disc at landing, (2) increases the descent time, (3) decreases the inclination (or nutation) angle, and (4) decreases the fluttering amplitude while falling. We conclude by commenting on how the corresponding information can be used as a predictive model for objects free falling in stratified fluids.

  16. The Challenge of Fluid Flow

    Indian Academy of Sciences (India)

    Home; Journals; Resonance – Journal of Science Education; Volume 10; Issue 8. The Challenge of Fluid Flow - The Diversity of Flow Phenomena. Roddam Narasimha. General Article Volume 10 Issue 8 August 2005 pp 67-79. Fulltext. Click here to view fulltext PDF. Permanent link:

  17. The Challenge of Fluid Flow

    Indian Academy of Sciences (India)

    Home; Journals; Resonance – Journal of Science Education; Volume 10; Issue 9. The Challenge of Fluid Flow - What One Can and Cannot Do. Roddam Narasimha. General Article Volume 10 Issue 9 September 2005 pp 6-22. Fulltext. Click here to view fulltext PDF. Permanent link:

  18. Observing magnetic objects in fluids

    NARCIS (Netherlands)

    Hageman, Tijmen Antoon Geert

    2018-01-01

    This thesis describes two topics dealing with objects moving through fluids. The first project considers centimetre-sized magnetic particles submerged in a turbulent water flow. We have studied how these particles interact with each other and self-assemble into clusters. By investigating their

  19. Fluid Mechanics of Fish Swimming

    Indian Academy of Sciences (India)

    Home; Journals; Resonance – Journal of Science Education; Volume 14; Issue 1. Fluid Mechanics of Fish Swimming - Lift-based Propulsion. Jaywant H Arakeri. General Article Volume 14 Issue 1 January 2009 pp 32-46. Fulltext. Click here to view fulltext PDF. Permanent link:

  20. Mixed Fluid Conditions: Capillary Phenomena

    KAUST Repository

    Santamarina, Carlos

    2017-07-06

    Mixed fluid phenomena in porous media have profound implications on soil-atmosphere interaction, energy geotechnology, environmental engineering and infrastructure design. Surface tension varies with pressure, temperature, solute concentration, and surfactant concentration; on the other hand, the contact angle responds to interfacial tensions, surface topography, invasion velocity, and chemical interactions. Interfaces are not isolated but interact through the fluid pressure and respond to external fields. Jumps, snap-offs and percolating wetting liquids along edges and crevices are ubiquitous in real, non-cylindrical porous networks. Pore- and macroscale instabilities together with pore structure variability-and-correlation favor fluid trapping and hinder recovery efficiency. The saturation-pressure characteristic curve is affected by the saturation-history, flow-rate, the mechanical response of the porous medium, and time-dependent reactive and diffusive processes; in addition, there are salient differences between unsaturation by internal gas nucleation and gas invasion. Capillary forces add to other skeletal forces in the porous medium and can generate open-mode discontinuities when the capillary entry pressure is high relative to the effective stress. Time emerges as an important variable in mixed-fluid conditions and common quasi-static analyses may fail to capture the system response.