WorldWideScience

Sample records for bioelectrical impedance method

  1. Bioelectrical Impedance Methods for Noninvasive Health Monitoring: A Review

    Directory of Open Access Journals (Sweden)

    Tushar Kanti Bera

    2014-01-01

    Full Text Available Under the alternating electrical excitation, biological tissues produce a complex electrical impedance which depends on tissue composition, structures, health status, and applied signal frequency, and hence the bioelectrical impedance methods can be utilized for noninvasive tissue characterization. As the impedance responses of these tissue parameters vary with frequencies of the applied signal, the impedance analysis conducted over a wide frequency band provides more information about the tissue interiors which help us to better understand the biological tissues anatomy, physiology, and pathology. Over past few decades, a number of impedance based noninvasive tissue characterization techniques such as bioelectrical impedance analysis (BIA, electrical impedance spectroscopy (EIS, electrical impedance plethysmography (IPG, impedance cardiography (ICG, and electrical impedance tomography (EIT have been proposed and a lot of research works have been conducted on these methods for noninvasive tissue characterization and disease diagnosis. In this paper BIA, EIS, IPG, ICG, and EIT techniques and their applications in different fields have been reviewed and technical perspective of these impedance methods has been presented. The working principles, applications, merits, and demerits of these methods has been discussed in detail along with their other technical issues followed by present status and future trends.

  2. Evaluation of segmental body composition by gender in obese children using bioelectric impedance analysis method

    Directory of Open Access Journals (Sweden)

    İhsan Çetin

    2015-12-01

    Full Text Available Objective: In this study, it was aimed to evaluate segmental body composition of children diagnosed with obesity using bioelectrical impedance analysis method in terms of different gender. Methods: 48 children, aged between 6-15 years, 21 of whom were boys while 27 were girls, diagnosed with obesity in Erciyes University Medical Faculty Department of Pediatric Endocrinology Outpatient Clinic were included in our study from April to June in 2011. Those over 95 percentile were defined as obese group. Tanita BC-418 device was used to analyze the body composition. Results: As a result of bioelectrical impedance analysis, lean body mass and body muscle mass were found to be statistically significantly higher in obese girls compared with obese boys. However, lean mass of the left arm, left leg muscle mass and basal metabolic rate were found to be statistically significantly lower in obese girls compared with obese boys. Conclusion: Consequently, it may be suggest that segmental analysis, where gender differences are taken into account, can provide proper exercise pattern and healthy way of weight loss in children for prevention of obesity and associated diseases including obesity and type 2 diabetics and cardiovascular diseases.

  3. Bioelectrical impedance analysis--part I

    DEFF Research Database (Denmark)

    Kyle, Ursula G; Bosaeus, Ingvar; De Lorenzo, Antonio D;

    2004-01-01

    The use of bioelectrical impedance analysis (BIA) is widespread both in healthy subjects and patients, but suffers from a lack of standardized method and quality control procedures. BIA allows the determination of the fat-free mass (FFM) and total body water (TBW) in subjects without significant ...

  4. Perioperative bioelectrical impedence analysis in neurosurgery.

    Science.gov (United States)

    El-Dawlatly, Abdelazeem A

    2005-10-01

    The use of bioelectrical impedence (BI) measurement to assess body composition has recently attracted the attention of anesthesiologists. Analysis of BI provides a non-invasive method to quantify fluid distribution in different body compartments. This study was designed to assess whether BI analysis reflects fluid depletion in neurosurgical patients with moderate blood loss. Six adult male patients scheduled for elective craniotomy under general anesthesia were studied. Exclusion criteria included patients with cardio-respiratory disease. BI analysis was performed at three stages, A, day before operation, B, during surgery and C, on the first postoperative day. Total body resistivity was measured by BI analysis with a four-terminal portable impedence analyzer. At each frequency, impedence was calculated as resistance (Rx)2 + reactance (Rc)2. The mean values of total body water (TBW) at stages A, B and C were 39.8 L (range: 33.1-46.7 L), 43.2 L (range: 33.1-66.2 L) and 36.8 L (range: 22.4-36.3 L) respectively with significant differences (P<0.05). The impedence at the three frequencies during stages A, B and C showed significant differences (P<0.05). In conclusion, we have found that in male neurosurgical patients multiple frequency BI measurements has reflected fluid balance perioperatively. Whether this observation remains true for other surgical procedures with massive blood loss, yet to be further investigated.

  5. Anisotropic bioelectrical impedance determination of subcutaneous fat thickness

    Science.gov (United States)

    Hernández-Becerra, P. A. I.; Delgadillo-Holtfort, I.; Balleza-Ordaz, M.; Huerta-Franco, M. R.; Vargas-Luna, M.

    2014-11-01

    Preliminary results have shown that bioelectrical impedance measurements performed on different parts of the human body strongly depend upon the subcutaneous fat of the considered region. In this work, a method for the determination of subcutaneous fat thickness is explored. Within this method the measurement of the bioelectrical impedance response of the fat-muscle system, both along the direction defined by the muscle fibers and along the corresponding perpendicular direction, are performed. Measurements have been carried out on human female and male subjects of ages around 25 years old at the region of the biceps. Correlation has been performed with skinfold caliper measurements.

  6. Validity of estimating limb muscle volume by bioelectrical impedance.

    Science.gov (United States)

    Miyatani, M; Kanehisa, H; Masuo, Y; Ito, M; Fukunaga, T

    2001-07-01

    The present study aimed to investigate the validity of estimating muscle volume by bioelectrical impedance analysis. Bioelectrical impedance and series cross-sectional images of the forearm, upper arm, lower leg, and thigh on the right side were determined in 22 healthy young adult men using a specially designed bioelectrical impedance acquisition system and magnetic resonance imaging (MRI) method, respectively. The impedance index (L(2)/Z) for every segment, calculated as the ratio of segment length squared to the impedance, was significantly correlated to the muscle volume measured by MRI, with r = 0.902-0.976 (P estimation was 38.4 cm(3) for the forearm, 40.9 cm(3) for the upper arm, 107.2 cm(3) for the lower leg, and 362.3 cm(3) for the thigh. Moreover, isometric torque developed in elbow flexion or extension and knee flexion or extension was significantly correlated to the L(2)/Z values of the upper arm and thigh, respectively, with correlation coefficients of 0.770-0.937 (P knee flexors or extensors. Thus the present study indicates that bioelectrical impedance analysis may be useful to predict the muscle volume and to investigate possible relations between muscle size and strength capability in a limited segment of the upper and lower limbs.

  7. Bioelectric impedance phase angle in breast carcinoma

    Directory of Open Access Journals (Sweden)

    Ruchi Tyagi

    2014-01-01

    Full Text Available Context: Worldwide breast cancer is the most frequently diagnosed life threatening cancer and the leading cause of death in women. Bioelectric impedance analysis (BIA affords an emerging opportunity to assess prognosis because of its ability to non invasively assess cell and plasma membrane structure and function by means of phase angle. Aims: To compare the phase angle between patients of breast cancer and their matched control with the help of BIA. Settings and Design: After taking clearance from ethical committee, a total of 34 female cases of histologically proven infiltrating ductal breast carcinoma were included from the surgery IPD, department of surgery. Equal numbers of the matched controls were recruited from the friends and relatives of cases. Materials and Methods: Bio Electrical Impedance Analyzer (BIA BODY STAT QUAD SCAN 4000 was used to measure resistance (R and reactance (Xc by recording a voltage drop in applied current. Phase angle is the ratio of reactance to resistance and is a measure of cell vitality. Statistical analysis used: Unpaired "t" test was applied. Results: In control group, the phase angle showed a mean of 5.479 whereas in test group, it showed a mean value of 4.726. The P value showed a significant difference (P < 0.0001. The smaller the phase angle values were higher was the tumor, nodes, metastases (TNM staging. The phase angles differed significantly from the healthy age matched control values. Conclusions: This study demonstrated that phase angle is a strong predictor of severity of breast cancer and differed significantly between the two groups.

  8. Experimental verification of depolarization effects in bioelectrical impedance measurement.

    Science.gov (United States)

    Chen, Xiaoyan; Lv, Xinqiang; Du, Meng

    2014-01-01

    The electrode polarization effects on bioelectrical impedance measurement at low-frequency cannot be ignored. In this paper, the bioelectrical data of mice livers are measured to specify the polarization effects on the bio-impedance measurement data. We firstly introduce the measurement system and methodology. Using the depolarization method, the corrected results are obtained. Besides, the specific effects of electrode polarization on bio-impedance measurement results are investigated using comparative analysis of the previous and posterior correction results from dielectric spectroscopy, Cole-Cole plot, conductivity and spectroscopy of dissipation tangent. Experimental results show that electrode polarization has a significant influence on the characteristic parameters of mouse liver tissues. To be specific, we see a low-frequency limit resistance R0 increase by 19.29%, a reactance peak XP increase by 8.50%, a low-frequency limit conductivity Kl decrease by 17.65% and a dissipation peak tangent decrease by 160%.

  9. Bioelectrical impedance analysis (BIA): a proposal for standardization of the classical method in adults

    Science.gov (United States)

    González-Correa, C. H.; Caicedo-Eraso, J. C.

    2012-12-01

    The accuracy of BIA measurements is limited by different sources of error such as physical model, cross sectional area, ethnicity, body hydration, age and level of body fat among other variables. Equation for each population is required as they can produce overestimation when manufacturer's equations are used. The classical measurements hand to foot has shown better correlation against hydrodensitometry than foot to foot or hand to hand. However there is a lack for an accepted standard of BIA procedures. This is compounded when there is not a good report of the BIA study's methodology; hence the comparability between the results is poor and reduces the reliability of the method. Perhaps, standardization of methods would be the first step for BIA studies to move forward and subsequently improve its accuracy. Standardized procedures could also minimize the impact of these variables on studies results. The aim of this study was to propose a protocol as a checklist to standardize BIA procedures and produce comparable results from future studies performed with the classic hand-foot configuration in adults.

  10. [Effects of different electrodes on bioelectrical impedance values].

    Science.gov (United States)

    Nakadomo, F; Tanaka, K; Yokoyama, T; Maeda, K

    1990-01-01

    Effects of different electrodes on bioelectrical impedance values measured by the Selco bioelectrical impedance plethysmograph (SIF-881, Japan) were investigated using 8 adult females (age: 35.3 +/- 7.6 yr, Ht: 156.9 +/- 3.8 cm, Wt: 57.1 +/- 9.9 kg, and hydrodensitometrically determined body fat: 29.4 +/- 6.0%). The Lectec MP3000 electrode (Liberty Carton, USA) and the Bipolar electrode (Sanwa, Japan) produced significantly higher impedance values when compared to the Disposable electrode (Adovance, Japan) and the ECG electrode (Nihon Kohden, Japan). The coefficient of variation was significantly lower for the Disposable electrode (0.8%) and the ECG electrode (0.2%) than that for the Lectec MP3000 electrode (2.3%) and the Bipolar electrode (4.9%). In conclusion, the ECG electrode provides higher bioelectrical impedance values with the highest reproducibility in the assessment of human body composition by the bioelectrical impedance plethysmography.

  11. Bioelectrical impedance analysis for an endangered desert fish—Data

    Data.gov (United States)

    U.S. Geological Survey, Department of the Interior — These data were used to examine the effectiveness of a non-lethal tool (Bioelectrical Impedance Analysis, "BIA") to estimate the physiological condition of...

  12. The comparative evaluation of patients′ body dry weight under hemodialysis using two methods: Bioelectrical impedance analysis and conventional method

    Directory of Open Access Journals (Sweden)

    Neda Alijanian

    2012-01-01

    Full Text Available Background: Dry weight (DW is an important concept related to patients undergoing hemodialysis. Conventional method seems to be time consuming and operator dependent. Bio impedance analysis (BIA is a new and simple method reported to be an accurate way for estimating DW. In this study, we aimed to compare the conventional estimation of DW with measuring DW by BIA. Materials and Methods: This study involved 130 uremic patients, performed in Isfahan, Iran. DW was calculated by both conventional (CDW and BIA (BIADW method and results were compared based on different grouping factors including sex, underlying cause of renal failure (RF (diabetic RF and non-diabetic RF, body mass index (BMI status, and sessions of hemodialysis. We also calculated the difference between DWs of 2 methods (DW diff = CDW-BIADW. Results: The mean of BIADW was significantly lower than CDW (57.20 ± 1.82 vs 59.36 ± 1.77, P value < 0.001. After grouping cases according to the underlying cause, BMI, sex, and dialysis sessions BIADW was significantly lower than CDW. Conclusion: Based on the combination of problems with CDW measurement which are corrected by BIA, and more clinical reliability of CDW, we concluded that although conventional method is a time-consuming and operator-dependent way to assess DW, DW could be estimated by combining both of these methods by finding the mathematic correlation between these methods.

  13. BIOELECTRICAL IMPEDANCE VECTOR ANALYSIS IDENTIFIES SARCOPENIA IN NURSING HOME RESIDENTS

    Science.gov (United States)

    Loss of muscle mass and water shifts between body compartments are contributing factors to frailty in the elderly. The body composition changes are especially pronounced in institutionalized elderly. We investigated the ability of single-frequency bioelectrical impedance analysis (BIA) to identify b...

  14. A comparison of skinfolds and leg-to-leg bioelectrical impedance for the assessment of body composition in children

    Science.gov (United States)

    Goss, Fredric; Robertson, Robert; Williams, Allison; Sward, Kathy; Abt, Kristi; Ladewig, Melissa; Timmer, Jeffrey; Dixon, Curt

    2003-01-01

    Background This field-based investigation examined the congruence between skinfolds and bioelectrical impedance in assessing body composition in children. Methods Subjects were 162 female and 160 male children 10–15 years of age. Skinfold measures obtained at the triceps and medial calf and a leg-to-leg bioelectrical impedance system were used to determine percent fat using child-specific equations. Pearson product moment correlations were performed on the percent fat values obtained using skinfolds and bioelectric impedance for the entire data set. Separate correlations were also conducted on gender and age/gender subsets. Dependent t tests were used to compare the two techniques. Results Percent fat did not differ between skinfolds and bioelectrical impedance for the total subject pool. Bioelectrical impedance overestimated percent fat in girls by 2.6% and underestimated percent fat in boys by 1.7% (p < 0.01). Correlations between skinfolds and bioelectrical impedance ranged from r = 0.51 to r = 0.90. Conclusions Leg-to-leg bioelectrical impedance may be a viable alternative field assessment technique that is comparable to skinfolds. The small differences in percent fat between the two techniques may have limited practical significance in school-based health-fitness settings. PMID:14498990

  15. Smart Multi-Frequency Bioelectrical Impedance Spectrometer for BIA and BIVA Applications.

    Science.gov (United States)

    Harder, Rene; Diedrich, Andre; Whitfield, Jonathan S; Buchowski, Macie S; Pietsch, John B; Baudenbacher, Franz J

    2016-08-01

    Bioelectrical impedance analysis (BIA) is a noninvasive and commonly used method for the assessment of body composition including body water. We designed a small, portable and wireless multi-frequency impedance spectrometer based on the 12 bit impedance network analyzer AD5933 and a precision wide-band constant current source for tetrapolar whole body impedance measurements. The impedance spectrometer communicates via Bluetooth with mobile devices (smart phone or tablet computer) that provide user interface for patient management and data visualization. The export of patient measurement results into a clinical research database facilitates the aggregation of bioelectrical impedance analysis and biolectrical impedance vector analysis (BIVA) data across multiple subjects and/or studies. The performance of the spectrometer was evaluated using a passive tissue equivalent circuit model as well as a comparison of body composition changes assessed with bioelectrical impedance and dual-energy X-ray absorptiometry (DXA) in healthy volunteers. Our results show an absolute error of 1% for resistance and 5% for reactance measurements in the frequency range of 3 kHz to 150 kHz. A linear regression of BIA and DXA fat mass estimations showed a strong correlation (r(2)=0.985) between measures with a maximum absolute error of 6.5%. The simplicity of BIA measurements, a cost effective design and the simple visual representation of impedance data enables patients to compare and determine body composition during the time course of a specific treatment plan in a clinical or home environment.

  16. BODY COMPOSITION OF YOUNG PEOPLE AGED 17-18 YEARS, PRACTICING AND NOT PRACTICING SWIMMING, WITH THE USE OF THE BIOELECTRICAL IMPEDANCE METHOD

    Directory of Open Access Journals (Sweden)

    Jendrysek Marek

    2015-11-01

    Full Text Available Purpose: Body composition evaluation of youth aged 17-18 of a different physical activity with the help of bioelectric impedance method. Material and Methods: 18 boys practicing swimming and 19 boys not practicing it took part in the study, making up a control group. Height, weight, BMI, lean body mass, the content of fat and water, Rohr factor were evaluated. Non-parametric Mann-Whitney test has been used to evaluate the differences in the range of the tissue components between the two groups. Results: Statistically significant differences were found on the p<0,05 level in % fat content. Mean body weight in experimental group was 71.5 kg, while in control group it was 69.4 kg. Minimum and maximum weight in group of swimming-practicing persons was: 56.6-92.2 kg. Increased body weight in the group of swimmers can result from greater amount of active tissue in this group compared with persons of low physical activity. Proportionally, it amounted to 64.3 kg and 61.3 kg. In the tested groups, minimal and maximal values of amount of active tissue proportionately amounted to: 54.1-78 and 49.5-72,3 kg. Conclusions: Physical activity modifies body composition. Active lifestyle is one of the methods for prevention of overweight and obesity.

  17. The use of bioelectrical impedance analysis for body composition in epidemiological studies

    DEFF Research Database (Denmark)

    Böhm, A; Heitmann, B L

    2013-01-01

    BACKGROUND/OBJECTIVES: Bioelectrical impedance analysis (BIA) is a relatively simple, inexpensive and non-invasive technique to measure body composition and is therefore suitable in field studies and larger surveys. SUBJECTS/METHODS: We performed an overview of BIA-derived body fat percentages (BF...

  18. Bioelectrical impedance analysis of bovine milk fat

    Science.gov (United States)

    Veiga, E. A.; Bertemes-Filho, P.

    2012-12-01

    Three samples of 250ml at home temperature of 20°C were obtained from whole, low fat and fat free bovine UHT milk. They were analysed by measuring both impedance spectra and dc conductivity in order to establish the relationship between samples related to fat content. An impedance measuring system was developed, which is based on digital oscilloscope, a current source and a FPGA. Data was measured by the oscilloscope in the frequency 1 kHz to 100 kHz. It was showed that there is approximately 7.9% difference in the conductivity between whole and low fat milk whereas 15.9% between low fat and free fat one. The change of fatness in the milk can be significantly sensed by both impedance spectra measurements and dc conductivity. This result might be useful for detecting fat content of milk in a very simple way and also may help the development of sensors for measuring milk quality, as for example the detection of mastitis.

  19. Bioelectrical impedance analysis for bovine milk: Preliminary results

    Science.gov (United States)

    Bertemes-Filho, P.; Valicheski, R.; Pereira, R. M.; Paterno, A. S.

    2010-04-01

    This work reports the investigation and analysis of bovine milk quality by using biological impedance measurements using electrical impedance spectroscopy (EIS). The samples were distinguished by a first chemical analysis using Fourier transform midinfrared spectroscopy (FTIR) and flow citometry. A set of milk samples (100ml each) obtained from 17 different cows in lactation with and without mastitis were analyzed with the proposed technique using EIS. The samples were adulterated by adding distilled water and hydrogen peroxide in a controlled manner. FTIR spectroscopy and flow cytometry were performed, and impedance measurements were made in a frequency range from 500Hz up to 1MHz with an implemented EIS system. The system's phase shift was compensated by measuring saline solutions. It was possible to show that the results obtained with the Bioelectrical Impedance Analysis (BIA) technique may detect changes in the milk caused by mastitis and the presence of water and hydrogen peroxide in the bovine milk.

  20. Bioelectrical impedance analysis for the prediction of hot carcass weight in buffalo calf

    Directory of Open Access Journals (Sweden)

    Leopoldo Iannuzzi

    2010-01-01

    Full Text Available Twenty young buffalo male calves were fed ad libitum with a total mix ration and with vitamin-mineral integration for 14 months. Seven days before slaughter, the animals were weighed and bioelectrical impedance measurements were collected in live animals. Physical and chemical characteristics were assessed on the Longissimus dorsi muscle after slaughter. Correlations and regression equations were calculated to determine the possible use of bioelectrical impedance for evaluating hot carcass weight. Bioelectrical impedance analysis at different frequencies, simple correlation and analysis of regression were examined for all the data collected, supporting the possibility of hot carcass weight prediction with equation at multifrequency. The results show that, probably due to the variability in animal live weight, the distribution of the colour parameters was not normally distributed. Moreover, using different frequencies of resistance and reactance, hot carcass weight in buffalo may be predicted with the following equation: Y=98.47–8.84(Rs100KHz+4.41(Rs1000 KHz-116.27(Xc5 KHz+51.04(Xc50 KHz+20.30(Xc100 KHz-33.92(Xc500 KHz+9.01(Xc1000 KHz±ε (Adjusted R Square value of .907 and SE of 5.728 However, further studies are required to improve the technique also in buffalo, after standardization of the method.

  1. Standardisation of bioelectrical impedance analysis for the estimation of body composition in healthy paediatric populations

    DEFF Research Database (Denmark)

    Brantlov, Steven; Jødal, Lars; Lange, Aksel

    2017-01-01

    BACKGROUND: Bioelectrical impedance analysis (BIA) requires a high degree of standardisation in order to ensure valid and reproducible impedance measurements. The overall aim of this review was to study the degree to which BIA papers conducted in healthy paediatric populations (aged 0-17 years......) were standardised. METHODS: Literature was identified on the basis of a systematic search of internationally-recognised electronic databases and hand searching of the reference lists of the included papers in order to identify additional relevant papers. The review was limited to lead-type BIA devices...

  2. Bioelectrical Impedance Vector Analysis and Muscular Fitness in Healthy Men

    Science.gov (United States)

    Rodríguez-Rodríguez, Fernando; Cristi-Montero, Carlos; González-Ruíz, Katherine; Correa-Bautista, Jorge Enrique; Ramírez-Vélez, Robinson

    2016-01-01

    Muscle strength can define the general muscular fitness (MF) measurable through hand-grip strength (HG), which is a factor that relates to the health of people of different ages. In this study we evaluated the muscle strength together with a bioimpedance electric analysis in 223 healthy Colombian adult subjects. The bioelectrical impedance vector analysis (BIVA) was conducted to determine the resistance (R), reactance (Xc) and phase angle (PhA). We classified the subjects into three groups (for tertiles), obtaining lower values of R and Xc in subjects with lower HG, plus a high correlation between PhA and HG. An increase in the level of PhA is associated with a high level of MF in a sample of healthy Latin American adult men. The BIVA’s parameters and PhA are a potentially effective preventive measure to be integrated into routine screening in the clinical setting. PMID:27384579

  3. Bioelectrical Impedance Vector Analysis and Muscular Fitness in Healthy Men

    Directory of Open Access Journals (Sweden)

    Fernando Rodríguez-Rodríguez

    2016-07-01

    Full Text Available Muscle strength can define the general muscular fitness (MF measurable through hand-grip strength (HG, which is a factor that relates to the health of people of different ages. In this study we evaluated the muscle strength together with a bioimpedance electric analysis in 223 healthy Colombian adult subjects. The bioelectrical impedance vector analysis (BIVA was conducted to determine the resistance (R, reactance (Xc and phase angle (PhA. We classified the subjects into three groups (for tertiles, obtaining lower values of R and Xc in subjects with lower HG, plus a high correlation between PhA and HG. An increase in the level of PhA is associated with a high level of MF in a sample of healthy Latin American adult men. The BIVA’s parameters and PhA are a potentially effective preventive measure to be integrated into routine screening in the clinical setting.

  4. Muscle development in healthy children evaluated by bioelectrical impedance analysis.

    Science.gov (United States)

    Uchiyama, Tomoka; Nakayama, Takahiro; Kuru, Satoshi

    2017-02-01

    This study aimed to use bioelectrical impedance analysis (BIA) to generate a new muscle density index (MDI), the MDI_BIA, to evaluate muscle development, and to demonstrate the changes that occur in the BIA-based muscle cross-sectional area index (MCAI_BIA) that accompany growth. We also sought to determine the traceability of chronological changes in the MDI_BIA and MCAI_BIA. Healthy children (n=112) aged 8.68±3.16years (0.33-14.00years) underwent bioelectrical impedance (BI) measurements of their upper arms, thighs, and lower legs. The MDI_BIA and MCAI_BIA were calculated, and cross-sectional investigations were conducted into the changes in these indices that accompanied growth. Data collected after 1.10±0.08years from 45 participants determined the traceability of the chronological changes in the MDI_BIA and MCAI_BIA. The MDI_BIA and MCAI_BIA were significantly positively correlated with age and height at all locations (Pmuscles from different perspectives. Except for the upper arm MDI_BIA, both indices at all locations regardless of age, showed significant chronological increases after an average period of 1.10years. The MDI_BIA and MCAI_BIA were significantly correlated with age and height in healthy children, and they showed significant chronological increases. Hence, these indices could be used to represent muscle development and muscle mass increases. BIA is non-invasive, convenient, and economical and it may be useful in evaluating muscle development and muscle cross-sectional areas in children. Copyright © 2016 The Japanese Society of Child Neurology. Published by Elsevier B.V. All rights reserved.

  5. Feasibility of bioelectrical impedance analysis in persons with severe intellectual and visual disabilities

    NARCIS (Netherlands)

    Havinga-Top, A. M.; Waninge, A.; van der Schans, C. P.; Jager-Wittenaar, H.

    2015-01-01

    Background: Body composition measurements provide important information about physical fitness and nutritional status. People with severe intellectual and visual disabilities (SIVD) have an increased risk for altered body composition. Bioelectrical impedance analysis (BIA) has been evidenced as a

  6. Body fat measurement by bioelectrical impedance and air displacement plethysmography: a cross-validation study to design bioelectrical impedance equations in Mexican adults

    Directory of Open Access Journals (Sweden)

    Valencia Mauro E

    2007-08-01

    Full Text Available Abstract Background The study of body composition in specific populations by techniques such as bio-impedance analysis (BIA requires validation based on standard reference methods. The aim of this study was to develop and cross-validate a predictive equation for bioelectrical impedance using air displacement plethysmography (ADP as standard method to measure body composition in Mexican adult men and women. Methods This study included 155 male and female subjects from northern Mexico, 20–50 years of age, from low, middle, and upper income levels. Body composition was measured by ADP. Body weight (BW, kg and height (Ht, cm were obtained by standard anthropometric techniques. Resistance, R (ohms and reactance, Xc (ohms were also measured. A random-split method was used to obtain two samples: one was used to derive the equation by the "all possible regressions" procedure and was cross-validated in the other sample to test predicted versus measured values of fat-free mass (FFM. Results and Discussion The final model was: FFM (kg = 0.7374 * (Ht2 /R + 0.1763 * (BW - 0.1773 * (Age + 0.1198 * (Xc - 2.4658. R2 was 0.97; the square root of the mean square error (SRMSE was 1.99 kg, and the pure error (PE was 2.96. There was no difference between FFM predicted by the new equation (48.57 ± 10.9 kg and that measured by ADP (48.43 ± 11.3 kg. The new equation did not differ from the line of identity, had a high R2 and a low SRMSE, and showed no significant bias (0.87 ± 2.84 kg. Conclusion The new bioelectrical impedance equation based on the two-compartment model (2C was accurate, precise, and free of bias. This equation can be used to assess body composition and nutritional status in populations similar in anthropometric and physical characteristics to this sample.

  7. Comparison of Bioelectrical Impedance and Skinfolds with Hydrodensitometry in the Assessment of Body Composition in Healthy Young Adults

    Science.gov (United States)

    Rutherford, W. J.; Diemer, Gary A.; Scott, Eric D.

    2011-01-01

    Bioelectrical impedance analysis (BIA) is a widely used method for estimating body composition, yet issues concerning its validity persist in the literature. The purpose of this study was to validate percentage of body fat (BF) values estimated from BIA and skinfold (SF) with those obtained from hydrodensitometry (HD). Percent BF values measured…

  8. Is bioelectrical impedance accurate for use in large epidemiological studies?

    Directory of Open Access Journals (Sweden)

    Merchant Anwar T

    2008-09-01

    Full Text Available Abstract Percentage of body fat is strongly associated with the risk of several chronic diseases but its accurate measurement is difficult. Bioelectrical impedance analysis (BIA is a relatively simple, quick and non-invasive technique, to measure body composition. It measures body fat accurately in controlled clinical conditions but its performance in the field is inconsistent. In large epidemiologic studies simpler surrogate techniques such as body mass index (BMI, waist circumference, and waist-hip ratio are frequently used instead of BIA to measure body fatness. We reviewed the rationale, theory, and technique of recently developed systems such as foot (or hand-to-foot BIA measurement, and the elements that could influence its results in large epidemiologic studies. BIA results are influenced by factors such as the environment, ethnicity, phase of menstrual cycle, and underlying medical conditions. We concluded that BIA measurements validated for specific ethnic groups, populations and conditions can accurately measure body fat in those populations, but not others and suggest that for large epdiemiological studies with diverse populations BIA may not be the appropriate choice for body composition measurement unless specific calibration equations are developed for different groups participating in the study.

  9. Bioelectrical impedance analysis for severe stroke patients with upper extremity hemiplegia

    Science.gov (United States)

    Yoo, Chanuk; Kim, Jaehyung; Yang, Yeongae; Lee, Jinsu; Jeon, Gyerok

    2016-01-01

    [Purpose] This study is to analyze bioimpedance parameters and occupational assessment for severe stroke patients with upper extremity hemiplegia. [Subjects and Methods] Experimental subjects were 20 hemiplegic stroke patients receiving rehabilitation therapy between November to October, 2015. Prediction marker (PM), and phase angle (θ), a nd characteristic frequency (fc) were measured using bioelectrical impedance spectroscopy (MultiScan 5000). Bioelectrical impedance vector analysis (BIVA) was also obtained from the bioimpedance data. Then, these values were compared with occupational assessment tools. [Results] A significant differences in PM, θ, fc, and BIVA were observed between paretic region and non-paretic region of 5 severe stroke patients. These results were in good agreement with occupational assessment (pinch and hand grip strength, and ADL by MBI). [Conclusion] There were significant differences in impedance parameters between paretic region and non-paretic region of 5 severe stroke patients with upper extremity hemiplegia. Thus, the BIA could be useful tool for evaluating hemiplegic stroke patients receiving the rehabilitation therapy in the clinical application. PMID:27821919

  10. Measurement of lean body mass using bioelectrical impedance analysis: a consideration of the pros and cons.

    Science.gov (United States)

    Sergi, Giuseppe; De Rui, Marina; Stubbs, Brendon; Veronese, Nicola; Manzato, Enzo

    2016-08-27

    The assessment of body composition has important applications in the evaluation of nutritional status and estimating potential health risks. Bioelectrical impedance analysis (BIA) is a valid method for the assessment of body composition. BIA is an alternative to more invasive and expensive methods like dual-energy X-ray absorptiometry, computerized tomography, and magnetic resonance imaging. Bioelectrical impedance analysis is an easy-to-use and low-cost method for the estimation of fat-free mass (FFM) in physiological and pathological conditions. The reliability of BIA measurements is influenced by various factors related to the instrument itself, including electrodes, operator, subject, and environment. BIA assumptions beyond its use for body composition are the human body is empirically composed of cylinders, FFM contains virtually all the water and conducting electrolytes in the body, and its hydration is constant. FFM can be predicted by BIA through equations developed using reference methods. Several BIA prediction equations exist for the estimation of FFM, skeletal muscle mass (SMM), or appendicular SMM. The BIA prediction models differ according to the characteristics of the sample in which they have been derived and validated in addition to the parameters included in the multiple regression analysis. In choosing BIA equations, it is important to consider the characteristics of the sample in which it has been developed and validated, since, for example, age- and ethnicity-related differences could sensitively affect BIA estimates.

  11. A practical guide to bioelectrical impedance analysis using the example of chronic obstructive pulmonary disease

    Directory of Open Access Journals (Sweden)

    Mattiucci-Guehlke Muriel

    2011-04-01

    Full Text Available Abstract Bioelectrical impedance analysis (BIA is a simple, inexpensive, quick and non-invasive technique for measuring body composition. The clinical benefit of BIA can be further enhanced by combining it with bioelectrical impedance vector analysis (BIVA. However, there is a substantial lack of information on the practical aspects of BIA/BIVA for those primarily interested in learning how to use and interpret this method in practice. The purpose of this article is to provide some guidance on the use of BIA/BIVA with special attention to practical considerations. This report reflects the authors' practical experience with the use of single-frequency BIA in combination with BIVA, particularly in COPD patients. First, the method and principles of BIA/BIVA are briefly described. Then, a practice-oriented approach to the interpretation and analysis of characteristic examples of altered nutritional and fluid status as seen with BIA/BIVA in COPD patients (e.g. malnutrition in obese and underweight patients with COPD, water retention is presented. As our examples show BIA/BIVA is an attractive and easy-to-learn tool for quick nutritional assessment and is therefore of great clinical benefit in daily practice.

  12. Bioelectrics

    CERN Document Server

    Heller, Richard

    2017-01-01

    This book focuses on bioelectrics, a new multidisciplinary field encompassing engineering and biology with applications to the medical, environmental, food, energy, and biotechnological fields. At present, 15 universities and institutes in Japan, the USA and the EU comprise the International Consortium of Bioelectrics, intended to advance this novel and important research field. This book will serve as an introductory resource for young scientists and also as a textbook for use by both undergraduate and graduate students – the world’s first such work solely devoted to bioelectrics.

  13. Evaluation of bioelectrical impedance analysis for identifying overweight individuals at increased cardiometabolic risk: a cross-sectional study.

    Directory of Open Access Journals (Sweden)

    Maxine J E Lamb

    Full Text Available OBJECTIVE: To investigate whether bioelectrical impedance analysis could be used to identify overweight individuals at increased cardiometabolic risk, defined as the presence of metabolic syndrome and/or diabetes. DESIGN AND METHODS: Cross-sectional study of a Scottish population including 1210 women and 788 men. The diagnostic performance of thresholds of percentage body fat measured by bioelectrical impedance analysis to identify people at increased cardiometabolic risk was assessed using receiver-operating characteristic curves. Odds ratios for increased cardiometabolic risk in body mass index categories associated with values above compared to below sex-specific percentage body fat thresholds with optimal diagnostic performance were calculated using multivariable logistic regression analyses. The validity of bioelectrical impedance analysis to measure percentage body fat in this population was tested by examining agreement between bioelectrical impedance analysis and dual-energy X-ray absorptiometry in a subgroup of individuals. RESULTS: Participants were aged 16-91 years and the optimal bioelectrical impedance analysis cut-points for percentage body fat for identifying people at increased cardiometabolic risk were 25.9% for men and 37.1% for women. Stratifying by these percentage body fat cut-points, the prevalence of increased cardiometabolic risk was 48% and 38% above the threshold and 24% and 19% below these thresholds for men and women, respectively. By comparison, stratifying by percentage body fat category had little impact on identifying increased cardiometabolic risk in normal weight and obese individuals. Fully adjusted odds ratios of being at increased cardiometabolic risk among overweight people with percentage body fat ≥ 25.9/37.1% compared with percentage body fat <25.9/37.1% as a reference were 1.93 (95% confidence interval: 1.20-3.10 for men and 1.79 (1.10-2.92 for women. CONCLUSION: Percentage body fat measured using

  14. Validation of bioelectrical-impedance analysis as a measurement of change in body composition in obesity

    Energy Technology Data Exchange (ETDEWEB)

    Kushner, R.F.; Kunigk, A.; Alspaugh, M.; Andronis, P.T.; Leitch, C.A.; Schoeller, D.A. (Univ. of Chicago, IL (USA))

    1990-08-01

    The bioelectrical-impedance-analysis (BIA) method accurately measures body composition in weight-stable subjects. This study validates the use of BIA to measure change in body composition. Twelve obese females underwent weight loss at a mean rate of 1.16 kg/wk. Body composition was measured by deuterium oxide dilution (D2O), BIA, and skinfold anthropometry (SFA) at baseline and at 5% decrements in weight. Highly significant correlations were obtained between D2O and BIA (r = 0.971) and between D2O and SFA (r = 0.932). Overall, BIA predicted change in fat-free mass with greater accuracy (to 0.4 kg) and precision (+/- 1.28 kg) than did anthropometry (to 0.8 kg and +/- 2.58 kg, respectively). We conclude that BIA is a useful clinical method for measuring change in body composition.

  15. Impact of hemodialysis on dual X-ray absorptiometry, bioelectrical impedance measurements, and anthropometry

    DEFF Research Database (Denmark)

    Abrahamsen, Bo; Hansen, T B; Høgsberg, I M;

    1996-01-01

    ), bioelectrical impedance analysis (BIA), and simple anthropometry in 19 patients (9 women and 10 men, mean age 46 y) before and after hemodialysis, removing 0.9-4.3 L (x: 2.8L) of ultrafiltrate. The reduction in fat-free mass (FFM) measured by DXA was highly correlated with the ultrafiltrate, as determined...

  16. Lipid and moisture content modeling of amphidromous Dolly Varden using bioelectrical impedance analysis

    Science.gov (United States)

    Stolarski, J.T.; Margraf, F.J.; Carlson, J.G.; Sutton, T.M.

    2014-01-01

    The physiological well-being or condition of fish is most commonly estimated from aspects of individual morphology. However, these metrics may be only weakly correlated with nutritional reserves stored as lipid, the primary form of accumulated energy in fish. We constructed and evaluated bioelectrical impedance analysis (BIA) models as an alternative method of assessing condition in amphidromous Dolly Varden Salvelinus malma collected from nearshore estuarine and lotic habitats of the Alaskan Arctic. Data on electrical resistance and reactance were collected from the lateral and ventral surfaces of 192 fish, and whole-body percent lipid and moisture content were determined using standard laboratory methods. Significant inverse relationships between temperature and resistance and reactance prompted the standardization of these data to a constant temperature using corrective equations developed herein. No significant differences in resistance or reactance were detected among spawning and nonspawning females after accounting for covariates, suggesting that electrical pathways do not intersect the gonads. Best-fit BIA models incorporating electrical variables calculated from the lateral and ventral surfaces produced the strongest associations between observed and model-predicted estimates of proximate content. These models explained between 6% and 20% more of the variability in laboratory-derived estimates of proximate content than models developed from single-surface BIA data and 32% more than models containing only length and weight data. While additional research is required to address the potential effects of methodological variation, bioelectrical impedance analysis shows promise as a way to provide high-quality, minimally invasive estimates of Dolly Varden lipid or moisture content in the field with only small increases in handling time.

  17. Evaluation of body composition in COPD patients using multifrequency bioelectrical impedance analysis

    Science.gov (United States)

    de Blasio, Francesca; de Blasio, Francesco; Miracco Berlingieri, Giulia; Bianco, Andrea; La Greca, Marta; Franssen, Frits M E; Scalfi, Luca

    2016-01-01

    Background Multifrequency bioelectrical impedance analysis (MF-BIA) is a technique that measures body impedance (Z) at different frequencies (5, 10, 50, 100, and 250 kHz). Body composition may be estimated using empirical equations, which include BIA variables or, alternatively, raw BIA data may provide direct information on water distribution and muscle quality. Objectives To compare raw MF-BIA data between COPD patients and controls and to study their relationship with respiratory and functional parameters in COPD patients. Methods MF-BIA was performed (Human Im-Touch analyzer) in 212 COPD patients and 115 age- and BMI-matched controls. Fat-free mass (FFM) and fat mass were estimated from BIA data, and low- to high-frequency (5 kHz/250 kHz) impedance ratio was calculated. Physical fitness, lung function and respiratory muscle strength were also assessed in COPD patients. Results After adjusting for age, weight, and body mass index, FFM and the 5/250 impedance ratio were lower in COPD patients (P<0.001) and were negatively affected by disease severity. In both male and female patients, the 5/250 impedance ratio was significantly correlated mainly with age (r=−0.316 and r=−0.346, respectively). Patients with a 5/250 impedance ratio below median value had lower handgrip strength (P<0.001), 6-minute walk distance (P<0.005), respiratory muscle strength (P<0.005), forced expiratory volume in 1 second (P<0.05) and vital capacity (P<0.005). Finally, the 5/250 impedance ratio was reduced (P<0.05) in patients with Global Initiative for Chronic Obstructive Lung Disease (GOLD) III and IV (compared to those with GOLD I and II) or a BODE index between 6 and 10 points (compared to those with BODE index between 1 and 5 points). Conclusion MF-BIA may be a useful tool for assessing body composition and nutritional status in COPD patients. In particular, the impedance ratio could give valuable information on cellular integrity and muscle quality.

  18. Bioelectrical impedance analysis and anthropometry for the determination of body composition in rats: effects of high-fat and high-sucrose diets

    Directory of Open Access Journals (Sweden)

    Larissa Rodrigues Neto Angéloco

    2012-06-01

    Full Text Available OBJECTIVE: The aim of the present study was to determine the impedance of Wistar rats treated with high-fat and high-sucrose diets and correlate their biochemical and anthropometric parameters with chemical analysis of the carcass. METHODS: Twenty-four male Wistar rats were fed a standard (AIN-93, high-fat (50% fat or high-sucrose (59% of sucrose diet for 4 weeks. Abdominal and thoracic circumference and body length were measured. Bioelectrical impedance analysis was used to determine resistance and reactance. Final body composition was determined by chemical analysis. RESULTS: Higher fat intake led to a high percentage of liver fat and cholesterol and low total body water in the High-Fat group, but these changes in the biochemical profile were not reflected by the anthropometric measurements or bioelectrical impedance analysis variables. Anthropometric and bioelectrical impedance analysis changes were not observed in the High-Sucrose group. However, a positive association was found between body fat and three anthropometric variables: body mass index, Lee index and abdominal circumference. CONCLUSION: Bioelectrical impedance analysis did not prove to be sensitive for detecting changes in body composition, but body mass index, Lee index and abdominal circumference can be used for estimating the body composition of rats.

  19. Use of bioelectrical impedance analysis to determine body composition changes in HIV-associated wasting.

    Science.gov (United States)

    Klauke, Stephan; Fischer, Harald; Rieger, Armin; Frühauf, Lukas; Staszewski, Schlomo; Althoff, Peter-Henning; Helm, Eilke Brigitte

    2005-04-01

    AIDS wasting syndrome results in loss of lean body mass and body cell mass. This 12-week, open-label study used bioelectrical impedance analysis to measure body composition changes in 24 patients with AIDS wasting syndrome receiving recombinant human growth hormone (r-hGH). The primary endpoint was percentage monthly change in body weight before/after r-hGH. Secondary endpoints included change from baseline in body composition (bioelectrical impedance analysis), isometric strength and CD4+ count. Twenty patients completed the study: r-hGH resulted in mean weight gains (+2.7%, P = 0.146), and significant increases in mean body cell mass (+8.0%, P = 0.0211), lean body mass (+4.8%, P = 0.0373) and water (+5.5%, P r-hGH was generally well tolerated; the most frequent adverse events were fever (7.3%) and diarrhoea (6.3%). Thus, bioelectrical impedance analysis can detect improved body cell mass independent of changes in body weight resulting from r-hGH treatment in patients with AIDS wasting syndrome.

  20. Bioelectrical impedance phase angle as a prognostic indicator in breast cancer

    Directory of Open Access Journals (Sweden)

    Dahlk Sadie L

    2008-08-01

    Full Text Available Abstract Background Bioelectrical impedance analysis (BIA is an easy-to-use, non-invasive, and reproducible technique to evaluate changes in body composition and nutritional status. Phase angle, determined by bioelectrical impedance analysis (BIA, detects changes in tissue electrical properties and has been hypothesized to be a marker of malnutrition. Since malnutrition can be found in patients with breast cancer, we investigated the prognostic role of phase angle in breast cancer. Methods We evaluated a case series of 259 histologically confirmed breast cancer patients treated at Cancer Treatment Centers of America. Kaplan Meier method was used to calculate survival. Cox proportional hazard models were constructed to evaluate the prognostic effect of phase angle independent of stage at diagnosis and prior treatment history. Survival was calculated as the time interval between the date of first patient visit to the hospital and the date of death from any cause or date of last contact/last known to be alive. Results Of 259 patients, 81 were newly diagnosed at our hospital while 178 had received prior treatment elsewhere. 56 had stage I disease at diagnosis, 110 had stage II, 46 had stage III and 34 had stage IV. The median age at diagnosis was 49 years (range 25 – 74 years. The median phase angle score was 5.6 (range = 1.5 – 8.9. Patients with phase angle 5.6 had 49.9 months (95% CI: 35.6 to 77.8; n = 130; the difference being statistically significant (p = 0.031. Multivariate Cox modeling, after adjusting for stage at diagnosis and prior treatment history found that every one unit increase in phase angle score was associated with a relative risk of 0.82 (95% CI: 0.68 to 0.99, P = 0.041. Stage at diagnosis (p = 0.006 and prior treatment history (p = 0.001 were also predictive of survival independent of each other and phase angle. Conclusion This study demonstrates that BIA-derived phase angle is an independent prognostic indicator in patients

  1. Validity of Bioelectrical Impedance Analysis to Estimation Fat-Free Mass in the Army Cadets

    Directory of Open Access Journals (Sweden)

    Raquel D. Langer

    2016-03-01

    Full Text Available Background: Bioelectrical Impedance Analysis (BIA is a fast, practical, non-invasive, and frequently used method for fat-free mass (FFM estimation. The aims of this study were to validate predictive equations of BIA to FFM estimation in Army cadets and to develop and validate a specific BIA equation for this population. Methods: A total of 396 males, Brazilian Army cadets, aged 17–24 years were included. The study used eight published predictive BIA equations, a specific equation in FFM estimation, and dual-energy X-ray absorptiometry (DXA as a reference method. Student’s t-test (for paired sample, linear regression analysis, and Bland–Altman method were used to test the validity of the BIA equations. Results: Predictive BIA equations showed significant differences in FFM compared to DXA (p < 0.05 and large limits of agreement by Bland–Altman. Predictive BIA equations explained 68% to 88% of FFM variance. Specific BIA equations showed no significant differences in FFM, compared to DXA values. Conclusion: Published BIA predictive equations showed poor accuracy in this sample. The specific BIA equations, developed in this study, demonstrated validity for this sample, although should be used with caution in samples with a large range of FFM.

  2. Validity and reliability of bioelectrical impedance analysis and skinfold thickness in predicting body fat in military personnel.

    Science.gov (United States)

    Aandstad, Anders; Holtberget, Kristian; Hageberg, Rune; Holme, Ingar; Anderssen, Sigmund A

    2014-02-01

    Previous studies show that body composition is related to injury risk and physical performance in soldiers. Thus, valid methods for measuring body composition in military personnel are needed. The frequently used body mass index method is not a valid measure of body composition in soldiers, but reliability and validity of alternative field methods are less investigated in military personnel. Thus, we carried out test and retest of skinfold (SKF), single frequency bioelectrical impedance analysis (SF-BIA), and multifrequency bioelectrical impedance analysis measurements in 65 male and female soldiers. Several validated equations were used to predict percent body fat from these methods. Dual-energy X-ray absorptiometry was also measured, and acted as the criterion method. Results showed that SF-BIA was the most reliable method in both genders. In women, SF-BIA was also the most valid method, whereas SKF or a combination of SKF and SF-BIA produced the highest validity in men. Reliability and validity varied substantially among the equations examined. The best methods and equations produced test-retest 95% limits of agreement below ±1% points, whereas the corresponding validity figures were ±3.5% points. Each investigator and practitioner must consider whether such measurement errors are acceptable for its specific use. Reprint & Copyright © 2014 Association of Military Surgeons of the U.S.

  3. Bioelectrical impedance analysis determination of water content and distribution in the horse.

    Science.gov (United States)

    Latman, Neal S; Keith, Natalie; Nicholson, Alan; Davis, Michael

    2011-06-01

    A horse's hydration status is critical to its health. The accurate and quantitative determination of it has been problematic because of size, length and density of hair, and uneven topography. The objective of this study was to validate a bioelectrical impedance analysis (BIA) method for objectively quantifying hydration status. Monofrequency BIA values and simple biometric measurements were used to construct predictive equations for total body water, plasma, extracellular, and intra-cellular fluid volumes. These predictive equations were correlated with standard body fluid dilution reference methods. The result was an accuracy of ±0.64% for total body water, ±0.17% for plasma volume, ±1.91% for extra-cellular fluid, and ±0.57% for intra-cellular fluid compartments. Less than 5 min was required for all of the measurements and determinations. Therefore, it appears that an accurate measurement of body fluid distribution can be performed on horses using a fast, easy, non-invasive, inexpensive BIA method.

  4. Bioelectrical impedance vector analysis for evaluating zinc supplementation in prepubertal and healthy children

    Directory of Open Access Journals (Sweden)

    Márcia Marília Gomes Dantas

    2015-09-01

    Full Text Available Background: The prevalence of abnormal nutritional status has increased in children and adolescents. Nutritional assessment is important for monitoring the health and nutritional status. Bioelectrical impedance vector analysis (BIVA combines changes in tissue hydration and structure and body composition that can be assessed. Objectives: The objective of this study was to use BIVA to evaluate nutritional status in 60 prepubertal children, aged between 8 and 9 years, supplemented with zinc, to detect possible changes in body composition. Design: We performed a randomized, controlled, triple-blind study. The children were divided into the control group (CG; sorbitol 10%, n=29 or the experimental group (EG; 10 mg Zn/day, n=31, and the duration of the experiment was 3 months. Anthropometric assessments were performed for all of the children. Results: The body mass index-for-age increased after oral zinc supplementation in the EG (p=0.005. BIVA indicated that the CG demonstrated a tendency for dehydration and decreased soft tissue and the EG demonstrated a tendency for increased soft tissue, primarily the fat-free mass. After analyses of BIVA ellipses, we observed that this method could detect improvements in body composition in healthy children supplemented with zinc. Conclusions: These results suggest that BIVA could be an auxiliary method for studying a small population undergoing zinc intervention.

  5. Diagnostic value of bioelectrical impedance analysis versus body mass index for detection of obesity among students.

    Science.gov (United States)

    Heydari, Seyed-Taghi; Ayatollahi, Seyed-Mohammad-Taghi; Zare, Najaf

    2011-06-01

    Obesity is a common nutritional problem in both developed and developing countries. The aim of this study was to determine the prevalence of overweightness and obesity using both bioelectrical impedance analysis (BIA) and body mass index (BMI). In this cross-sectional study, 288 healthy college students were selected. Socio-economic status questionnaires were completed and subjects' anthropometric features were measured by a trained nurse. BMI was calculated and body fat mass (BFM) and body fat percent (BF%) were obtained using BIA method by hand-to-hand Omron BF-500 set. Mean age of the subjects was 21.1±1.7 years. Based on BMI, 2.6% of males and 2.2% of females were obese while 15.7% and 9.6% were diagnosed to be overweight respectively. The correlation between BMI values and BFM were 0.883 and 0.908 in males and females respectively (Pcollege students compared with Iranian general population, especially in females. Additionally, BIA method was shown to be closely correlated with and as much valuable as BMI in regard to detection of obesity.

  6. Evaluation of body composition in COPD patients using multifrequency bioelectrical impedance analysis

    Directory of Open Access Journals (Sweden)

    de Blasio F

    2016-09-01

    Full Text Available Francesca de Blasio,1 Francesco de Blasio,2,3 Giulia Miracco Berlingieri,2 Andrea Bianco,3,4 Marta La Greca,1 Frits M E Franssen,5 Luca Scalfi1 1Department of Public Health, Medical School, “Federico II” University of Naples, 2Respiratory Medicine and Pulmonary Rehabilitation Section, Clinic Center, Private Hospital, Naples, 3Department of Medicine and Health Sciences “V Tiberio”, University of Molise, Campobasso, 4Department of Cardio-Thoracic and Respiratory Sciences, Second University of Naples, Naples, Italy; 5Department of Research and Education, CIRO, Horn, the NetherlandsBackground: Multifrequency bioelectrical impedance analysis (MF-BIA is a technique that measures body impedance (Z at different frequencies (5, 10, 50, 100, and 250 kHz. Body composition may be estimated using empirical equations, which include BIA variables or, alternatively, raw BIA data may provide direct information on water distribution and muscle quality.Objectives: To compare raw MF-BIA data between COPD patients and controls and to study their relationship with respiratory and functional parameters in COPD patients.Methods: MF-BIA was performed (Human Im-Touch analyzer in 212 COPD patients and 115 age- and BMI-matched controls. Fat-free mass (FFM and fat mass were estimated from BIA data, and low- to high-frequency (5 kHz/250 kHz impedance ratio was calculated. Physical fitness, lung function and respiratory muscle strength were also assessed in COPD patients.Results: After adjusting for age, weight, and body mass index, FFM and the 5/250 impedance ratio were lower in COPD patients (P<0.001 and were negatively affected by disease severity. In both male and female patients, the 5/250 impedance ratio was significantly correlated mainly with age (r=−0.316 and r=−0.346, respectively. Patients with a 5/250 impedance ratio below median value had lower handgrip strength (P<0.001, 6-minute walk distance (P<0.005, respiratory muscle strength (P<0.005, forced

  7. Bioelectrical impedance analysis: population reference values for phase angle by age and sex.

    Science.gov (United States)

    Barbosa-Silva, Maria Cristina G; Barros, Aluísio J D; Wang, Jack; Heymsfield, Steven B; Pierson, Richard N

    2005-07-01

    Phase angle is an indicator based on reactance and resistance obtained from bioelectrical impedance analysis (BIA). Although its biological meaning is still not clear, phase angle appears to have an important prognostic role. The aim of this study was to estimate population averages and SDs of phase angle that can be used as reference values. BIA and other methods used to evaluate body composition, including hydrodensitometry and total body water, were completed in 1967 healthy adults aged 18-94 y. Phase angle was calculated directly from body resistance and reactance, and fat mass (FM) was estimated from the combination of weight, hydrodensitometry, and total body water by using the 3-compartment Siri equation. Phase angle values were compared across categories of sex, age, body mass index (BMI), and percentage FM. Phase angle was significantly (P < 0.001) smaller in women than in men and was lower with greater age (P < 0.001). Phase angle increased with an increase in BMI and was significantly inversely associated with percentage fat in men. Phase angle was significantly predicted from sex, age, BMI, and percentage FM in multiple regression models. Phase angle differs across categories of sex, age, BMI, and percentage fat. These reference values can serve as a basis for phase angle evaluations in the clinical setting.

  8. Estimating body composition from skinfold thicknesses and bioelectrical impedance analysis in cystic fibrosis patients.

    Science.gov (United States)

    Alicandro, Gianfranco; Battezzati, Alberto; Bianchi, Maria Luisa; Loi, Silvana; Speziali, Chiara; Bisogno, Arianna; Colombo, Carla

    2015-11-01

    The accuracy of body composition estimates based on skinfold thickness measurements and bioelectrical impedance analysis (BIA) is not yet adequately explored in cystic fibrosis (CF). Using DXA as reference method we verified the accuracy of these techniques and identified predictors of body composition specific for CF. One hundred forty-two CF patients (age range: 8-31 years) underwent a DXA scan. Body fat percentage (BF%) was estimated from skinfolds, while fat free mass (FFM) from single-frequency 50 kHz BIA. Bland-Altman analysis showed poor intra-individual agreement between body composition data provided by DXA and BF% estimated from skinfolds or FFM estimated from BIA. The skinfolds of the upper arm were better predictors of BF% than BMI, while compared to other BIA measurements the best predictor of FFM was the R-index (Height(2)/Resistance). Due to poor accuracy at individual level, the estimates of body composition obtained from these techniques cannot be part of the standard nutritional assessment of CF patients until reliable CF-specific equations will become available. BMI has limited value in predicting body fatness in CF patients and should be used in combination with other predictors. Skinfolds of the upper arm and R-index are strongly related to BF% and FFM and should be tested in a large CF population to develop specific predictive equations. Copyright © 2015 European Cystic Fibrosis Society. Published by Elsevier B.V. All rights reserved.

  9. Quantitative Assessment of Fluid Accumulation Using Bioelectrical Impedance Analysis in Patients With Acute Decompensated Heart Failure.

    Science.gov (United States)

    Sakaguchi, Taiki; Yasumura, Kaori; Nishida, Hiroki; Inoue, Hiroyuki; Furukawa, Tetsuo; Shinouchi, Kazuya; Miura, Hiroyuki; Miyazaki, Koichi; Hamano, Gou; Koide, Masao; Abe, Haruhiko; Date, Motoo; Hirooka, Keiji; Koretsune, Yukihiro; Kusuoka, Hideo; Yasumura, Yoshio

    2015-01-01

    Acute decompensated heart failure (ADHF) is generally considered to be a problem of fluid volume overload, therefore accurately quantifying the degree of fluid accumulation is of critical importance in assessing whether adequate decongestion has been achieved. The aim of this study was to develop and validate a method to quantify the degree of fluid accumulation in patients with ADHF. Using multi-frequency bioelectrical impedance analysis (BIA), we measured extracellular water (ECW) volume in 130 ADHF patients on admission and at discharge. We also predicted optimal ECW volume using original equations based on data from 60 control subjects without the signs of HF. Measured/predicted (M/P) ratio of ECW in ADHF patients was observed to decrease from 1.26±0.25 to 1.04±0.17 during hospitalization (P<0.001). The amount of ECW volume reduction was significantly correlated with reduction in body weight (r=0.766, P<0.001). On multivariate analysis, higher M/P ratio of ECW at discharge was associated with increased risk of ADHF readmission or cardiac death within 6 months after discharge. Multi-frequency BIA-measured ECW was found to offer valuable information for analyzing the pathophysiology of ADHF, and may be a useful guide in the management of this disease.

  10. Effects of hydration and dehydration on body composition analysis: a comparative study of bioelectric impedance analysis and hydrodensitometry.

    Science.gov (United States)

    Thompson, D L; Thompson, W R; Prestridge, T J; Bailey, J G; Bean, M H; Brown, S P; McDaniel, J B

    1991-12-01

    Since 1983, bioelectric impedance has been researched with respect to its validity and reliability in the determination of body composition. It continues to be compared to hydrostatic weighing, the anthropometric "gold standard". This study was designed to investigate the relationship between bioelectric impedance analysis (BIA) and hydrodensitometry (HW) under three conditions: control, hydration and dehydration. Caucasian males (aged 18-44 years) served as subjects (n = 10). Body composition was determined by BIA and HW before intervention, 30 minutes post-hydration, and following a combination of exercise and sitting in a steam room to decrease body weight by two to four percent (mean = 2.81%). Statistical treatment by two-way analysis of variance for repeated measures revealed that although there were no significant differences between the two techniques of body composition determination under any of the three conditions, there was a statistically significant decrease in percent body fat determined in the dehydrated state as compared to the control and hydrated conditions. Recommendations include the determination of hydration state prior to engaging in body composition analysis by either method.

  11. NOTE: Spatial dependence of the phase in localized bioelectrical impedance analysis

    Science.gov (United States)

    Shiffman, C. A.; Aaron, R.; Altman, A.

    2001-04-01

    The variety of phase functions, θ(z) = arctan X(z)/R(z), observed earlier on the thighs of healthy and seriously ill subjects via localized bioelectrical impedance analysis, can be represented by a model which combines realistic thigh shapes with homogeneous, axially symmetric conductivity tensors. While quantitative results depend sensitively on the way current is injected, it appears to be generally true that dθ/dz φz (and vice versa), where φr and φz are the phases of the radial and longitudinal conductivity components.

  12. Bioelectrical impedance analysis and skinfold thickness sum in assessing body fat mass of renal dialysis patients.

    Science.gov (United States)

    Rodrigues, Natália Cristina Lima; Sala, Priscila Campos; Horie, Lilian Mika; Dias, Maria Carolina Gonçalves; Torrinhas, Raquel Susana Matos de Miranda; Romão, João Egídio; Cecconello, Ivan; Waitzberg, Dan Linetzky

    2012-07-01

    In chronic renal failure patients under hemodialysis (HD) treatment, the availability of simple, safe, and effective tools to assess body composition enables evaluation of body composition accurately, in spite of changes in body fluids that occur in dialysis therapy, thus contributing to planning and monitoring of nutritional treatment. We evaluated the performance of bioelectrical impedance analysis (BIA) and the skinfold thickness sum (SKF) to assess fat mass (FM) in chronic renal failure patients before (BHD) and after (AHD) HD, using air displacement plethysmography (ADP) as the standard method. This single-center cross-sectional trial involved comparing the FM of 60 HD patients estimated BHD and AHD by BIA (multifrequential; 29 women, 31 men) and by SKF with those estimated by the reference method, ADP. Body fat-free mass (FFM) was also obtained by subtracting the total body fat from the individual total weight. Mean estimated FM (kg [%]) observed by ADP BHD was 17.95 ± 0.99 kg (30.11% ± 1.30%), with a 95% confidence interval (CI) of 16.00 to 19.90 (27.56 to 32.66); mean estimated FM observed AHD was 17.92 ± 1.11 kg (30.04% ± 1.40%), with a 95% CI of 15.74 to 20.10 (27.28 to 32.79). Neither study period showed a difference in FM and FFM (for both kg and %) estimates by the SKF method when compared with ADP; however, the BIA underestimated the FM and overestimated the FFM (for both kg and %) when compared with ADP. The SKF, but not the BIA, method showed results similar to ADP and can be considered adequate for FM evaluation in HD patients. Copyright © 2012 National Kidney Foundation, Inc. Published by Elsevier Inc. All rights reserved.

  13. Prediction of extracellular water and total body water by multifrequency bio-electrical impedance in a Southeast Asian population

    NARCIS (Netherlands)

    Guricci, S.; Hatriyanti, Y.; Hautvast, J.G.A.J.; Deurenberg, P.

    1999-01-01

    Three different adult Indonesian population groups living on Sumatra (Palembang), Java (Depok) and Sulawesi (Makale) participated in a study on body composition. Body weight, body height and multifrequency bioelectrical impedance (1, 5, 50 and 100 kHz) were measured and in addition total body water

  14. Validity of bioelectrical impedance analysis to assess fat-free mass in head and neck cancer patients: an exploratory study

    NARCIS (Netherlands)

    Jager-Wittenaar, Harriët; Dijkstra, Pieter U.; Earthman, Carrie P.; Krijnen, Wim P.; Langendijk, Johannes A.; Laan, Bernard F.A. M. van der; Pruim, Jan; Roodenburg, Jan L.N.

    2013-01-01

    Bioelectrical impedance analysis (BIA) may be used to assess fet free mass (FFM) with reasonable validity based on mean-level comparisons, but differences between BIA and DXA may vary by about 4 kg in an individual patient. These results require confirmation in a larger sample of HNC patients. (Head

  15. Does bioelectrical impedance analysis accurately estimate the condition of threatened and endangered desert fish species?

    Science.gov (United States)

    Dibble, Kimberly L.; Yard, Micheal D.; Ward, David L.; Yackulic, Charles B.

    2017-01-01

    Bioelectrical impedance analysis (BIA) is a nonlethal tool with which to estimate the physiological condition of animals that has potential value in research on endangered species. However, the effectiveness of BIA varies by species, the methodology continues to be refined, and incidental mortality rates are unknown. Under laboratory conditions we tested the value of using BIA in addition to morphological measurements such as total length and wet mass to estimate proximate composition (lipid, protein, ash, water, dry mass, energy density) in the endangered Humpback Chub Gila cypha and Bonytail G. elegans and the species of concern Roundtail Chub G. robusta and conducted separate trials to estimate the mortality rates of these sensitive species. Although Humpback and Roundtail Chub exhibited no or low mortality in response to taking BIA measurements versus handling for length and wet-mass measurements, Bonytails exhibited 14% and 47% mortality in the BIA and handling experiments, respectively, indicating that survival following stress is species specific. Derived BIA measurements were included in the best models for most proximate components; however, the added value of BIA as a predictor was marginal except in the absence of accurate wet-mass data. Bioelectrical impedance analysis improved the R2 of the best percentage-based models by no more than 4% relative to models based on morphology. Simulated field conditions indicated that BIA models became increasingly better than morphometric models at estimating proximate composition as the observation error around wet-mass measurements increased. However, since the overall proportion of variance explained by percentage-based models was low and BIA was mostly a redundant predictor, we caution against the use of BIA in field applications for these sensitive fish species.

  16. Prediction of body composition of Iberian pigs by means bioelectrical impedance.

    Science.gov (United States)

    Daza, A; Mateos, A; Ovejero, I; Bote, C J López

    2006-01-01

    Twelve barrow Iberian pigs with an average weight at slaughter of 109.2kg were used to evaluate bioelectrical impedance procedures to predict the body composition of live pigs. Twelve hours before slaughter pigs were weighed, and a four-terminal body composition analyser (Model BIA-101, RJL Systems, Detroit, MI) was utilized to determine resistance (R(s) in Ω) and reactance (X(c) in Ω). The length values (L in cm) were measured between detector electrodes with a flexible steel tape. Twenty four hours after slaughter the left side of each carcass was separated using a scalpel into fat, lean, bone and skin. Multiple regression equations for estimating lean, fat, bone and skin amounts and lean, fat, bone and skin proportions with respect to slaughter weight were calculated. The live weight (LW) and L independent variables predicted 85.3% and 64.3% of the variability of the lean amount and lean proportion, respectively. The LW, X(c) and L variables accounted for 96% and 91.6% of the variation in fat quantity and fat proportion, respectively. The LW and R(s) accounted for 58.9% of the variation in bone amount, and the same variables predict 79.1% of the variability of bone percentage. The R(s) and L variables explained 68% of the variability of skin quantity and LW, R(s) and X(c) predicted 83.1% of the variation of skin proportion. Results from this experiment indicate that bioelectrical impedance may be of interest for body composition prediction of live Iberian pigs.

  17. Inter-sport variability of muscle volume distribution identified by segmental bioelectrical impedance analysis in four ball sports

    Directory of Open Access Journals (Sweden)

    Yamada Y

    2013-04-01

    Full Text Available Yosuke Yamada,1,2 Yoshihisa Masuo,3 Eitaro Nakamura,4 Shingo Oda5 1Laboratory of Sports and Health Science, Kyoto Prefectural University of Medicine, Kyoto, Japan; 2Japan Society for the Promotion of Science, Tokyo, Japan; 3Waseda University Research Institute for Elderly Health, Saitama, Japan; 4Department of Sport Science, Kyoto Iken College of Medicine and Health, Kyoto, Japan; 5Faculty of Health and Well-being, Kansai University, Osaka, Japan Abstract: The aim of this study was to evaluate and quantify differences in muscle distribution in athletes of various ball sports using segmental bioelectrical impedance analysis (SBIA. Participants were 115 male collegiate athletes from four ball sports (baseball, soccer, tennis, and lacrosse. Percent body fat (%BF and lean body mass were measured, and SBIA was used to measure segmental muscle volume (MV in bilateral upper arms, forearms, thighs, and lower legs. We calculated the MV ratios of dominant to nondominant, proximal to distal, and upper to lower limbs. The measurements consisted of a total of 31 variables. Cluster and factor analyses were applied to identify redundant variables. The muscle distribution was significantly different among groups, but the %BF was not. The classification procedures of the discriminant analysis could correctly distinguish 84.3% of the athletes. These results suggest that collegiate ball game athletes have adapted their physique to their sport movements very well, and the SBIA, which is an affordable, noninvasive, easy-to-operate, and fast alternative method in the field, can distinguish ball game athletes according to their specific muscle distribution within a 5-minute measurement. The SBIA could be a useful, affordable, and fast tool for identifying talents for specific sports. Keywords: discriminant analysis, cluster and factor analysis, segmental bioelectrical impedance analysis, baseball, lacrosse

  18. Bioelectrical impedance analysis in clinical practice: implications for hepatitis C therapy BIA and hepatitis C

    Directory of Open Access Journals (Sweden)

    Kahraman Alisan

    2010-08-01

    Full Text Available Abstract Background Body composition analysis using phase angle (PA, determined by bioelectrical impedance analysis (BIA, reflects tissue electrical properties and has prognostic value in liver cirrhosis. Objective of this prospective study was to investigate clinical use and prognostic value of BIA-derived phase angle and alterations in body composition for hepatitis C infection (HCV following antiviral therapy. Methods 37 consecutive patients with HCV infection were enrolled, BIA was performed, and PA was calculated from each pair of measurements. 22 HCV genotype 3 patients treated for 24 weeks and 15 genotype 1 patients treated for 48 weeks, were examined before and after antiviral treatment and compared to 10 untreated HCV patients at 0, 24, and 48 weeks. Basic laboratory data were correlated to body composition alterations. Results Significant reduction in body fat (BF: 24.2 ± 6.7 kg vs. 19.9 ± 6.6 kg, genotype1; 15.4 ± 10.9 kg vs. 13.2 ± 12.1 kg, genotype 3 and body cell mass (BCM: 27.3 ± 6.8 kg vs. 24.3 ± 7.2 kg, genotype1; 27.7 ± 8.8 kg vs. 24.6 ± 7.6 kg, genotype 3 was found following treatment. PA in genotype 3 patients was significantly lowered after antiviral treatment compared to initial measurements (5.9 ± 0.7° vs. 5.4 ± 0.8°. Total body water (TBW was significantly decreased in treated patients with genotype 1 (41.4 ± 7.9 l vs. 40.8 ± 9.5 l. PA reduction was accompanied by flu-like syndromes, whereas TBW decline was more frequently associated with fatigue and cephalgia. Discussion BIA offers a sophisticated analysis of body composition including BF, BCM, and TBW for HCV patients following antiviral regimens. PA reduction was associated with increased adverse effects of the antiviral therapy allowing a more dynamic therapy application.

  19. Smartphone-Based Bioelectrical Impedance Analysis Devices for Daily Obesity Management

    Directory of Open Access Journals (Sweden)

    Ahyoung Choi

    2015-09-01

    Full Text Available Current bioelectric impedance analysis (BIA systems are often large, cumbersome devices which require strict electrode placement on the user, thus inhibiting mobile capabilities. In this work, we developed a handheld BIA device that measures impedance from multiple frequencies (5 kHz~200 kHz with four contact electrodes and evaluated the BIA device against standard body composition analysis systems: a dual-energy X-ray absorptiometry (DXA system (GE Lunar Prodigy, GE Healthcare, Buckinghamshire, UK and a whole-body BIA system (InBody S10, InBody, Co. Ltd, Seoul, Korea. In the study, 568 healthy participants, varying widely in body mass index, age, and gender, were recruited at two research centers: the Samsung Medical Center (SMC in South Korea and the Pennington Biomedical Research Center (PBRC in the United States. From the measured impedance data, we analyzed individual body fat and skeletal muscle mass by applying linear regression analysis against target reference data. Results indicated strong correlations of impedance measurements between the prototype pathways and corresponding InBody S10 electrical pathways (R = 0.93, p < 0.0001. Additionally, body fat estimates from DXA did not yield significant differences (p > 0.728 (paired t-test, DXA mean body fat 29.45 ± 10.77 kg, estimated body fat 29.52 ± 12.53 kg. Thus, this portable BIA system shows a promising ability to estimate an individual’s body composition that is comparable to large stationary BIA systems.

  20. Analysis of body water compartments after a short sauna bath using bioelectric impedance analysis.

    Science.gov (United States)

    Servidio, M-F; Mohamed, E I; Maiolo, C; Hereba, A T; Perrone, F; Garofano, P; Iacopino, L

    2003-10-01

    Studies have suggested that long-term sauna bathing may lower blood pressure in persons with hypertension by causing a direct loss of extracellular water and plasma minerals. The objective of the present study was to evaluate the effect of short-term sauna bathing on body water compartments as estimated by bioelectric impedance analysis (BIA). We recruited 15 men [mean age (+/-SD) of 23.93+/-5.12 years and mean body mass index (BMI) of 23.25+/-2.84 kg/m(2)] and 10 women matched for age and BMI. Total body resistance, reactance, and impedance were measured for all participants using BIA, at baseline, after a short sauna bath, and after a rest period. Total, extracellular, and intracellular water compartments were calculated using BIA formulae. There were no significant differences for any of the body water compartments when comparing the measurements taken before and after the sauna bath and after the rest period. However, it remains to be determined whether or not BIA is sensitive to rapid changes in water volume.

  1. [Values of the phase angle by bioelectrical impedance; nutritional status and prognostic value].

    Science.gov (United States)

    Llames, L; Baldomero, V; Iglesias, M L; Rodota, L P

    2013-01-01

    Phase angle (PA) is the most established parameter from bioelectrical impedance analysis (BIA) for diagnosis of malnutrition and clinical prognosis, both associated with changes on cellular membrane integrity and alterations on fluids balance. PA expresses changes in quantity and quality of soft tissue mass (ie, cell membrane permeability and soft tissue hydration). A large body of clinical trials propose PA as a useful prognostic marker in clinical conditions like liver cirrhosis and breast, colon, pancreatic and lung cancer; positive association between PA and survival was also observed in surgical and HIV infected patients. Several authors suggest that PA can be an important tool in the evaluation of the clinical result or of the progression of the disease, and it can even be superior to other nutritional, biochemical or anthropometric indicators. Lack of reference values has limited its use in clinical and epidemiological situations. The purpose of this review is to describe PA reference values according to different clinical conditions as proposed in published scientific works.

  2. Accuracy of segmental bioelectrical impedance analysis for predicting body composition in pre- and postmenopausal women.

    Science.gov (United States)

    Tanaka, Noriko I; Hanawa, Satoshi; Murakami, Haruka; Cao, Zhen-Bo; Tanimoto, Michiya; Sanada, Kiyoshi; Miyachi, Motohiko

    2015-01-01

    This study aimed to compare the accuracy for predicting body composition using single-frequent segmental bioelectrical impedance analysis (BIA) between pre- and postmenopausal women. A total f 559 Japanese women aged 30-88yr were divided into 4 groups by questionnaire: natural menopause, pathological menopause, regular menstruation, or irregular menstruation. The measurement values by dual-energy X-ray absorptiometry were used as a reference of the body composition. In terms of the results, regardless of the menopausal status, BIA slightly but significantly overestimated the percentage of body fat (standard error of estimate: 5.3%-6.7%) and the leg lean soft tissue mass (LSTM; 5.1%-6.1%), and underestimated the LSTM in the whole body (6.2%-7.6%) and arm (2.8%-3.7%). The absolute values of the predictive error for leg LSTM were significantly higher in postmenopausal groups than in the premenopausal ones. The corresponding values for the whole body and arm LSTM, and the percentage of body fat were higher in premenopausal groups than in postmenopausal ones. In conclusion, the predictive accuracy of BIA for postmenopausal women is not inferior to that for premenopausal ones, unless we target the leg LSTM.

  3. Association of plasma adiponectin levels with cellular hydration state measured using bioelectrical impedance analysis in patients with COPD

    Directory of Open Access Journals (Sweden)

    Yoshikawa T

    2012-08-01

    Full Text Available Takahiro Yoshikawa,1 Hiroshi Kanazawa21Department of Sports Medicine, Osaka City University Graduate School of Medicine, 2Department of Respiratory Medicine, Osaka City University Graduate School of Medicine, Osaka, JapanBackground: It is widely recognized that chronic obstructive pulmonary disease (COPD includes a variety of extra pulmonary complications and comorbidities. Recently, adiponectin was shown to regulate cellular metabolism in humans. Cellular hydration state is affected by a variety of hormonal factors and regulates cellular metabolic state. Therefore, this study was designed to determine whether adiponectin is a possible factor involved in cellular hydration state in COPD.Methods: Thirty patients with COPD and 41 age-matched controls participated in the study. Plasma levels of total and high molecular weight (HMW adiponectin were measured and anthropometry and pulmonary function tests were conducted. Intracellular water (ICW, extracellular water (ECW, and ECW/ICW ratio, which are parameters of cellular hydration state, were measured using bioelectrical impedance analysis.Results: Higher levels of total and HMW adiponectin in plasma were found in patients with COPD compared with levels in controls. A significant inverse correlation was observed between body mass index and plasma levels of total and HMW adiponectin in the control group. However, this significant correlation was not observed in patients with COPD. The plasma levels of total and HMW adiponectin were also not significantly correlated with any pulmonary function parameters in patients with COPD. Regarding the state of cellular hydration, the plasma levels of total adiponectin were inversely correlated with the ECW/ICW ratio and positively with ICW values in patients with COPD. Moreover, closer correlations were found between these parameters and plasma HMW adiponectin levels.Conclusion: The results of the present study suggest a novel association of the plasma

  4. Estimation of prevalence of sarcopenia by using a new bioelectrical impedance analysis in Chinese community-dwelling elderly people.

    Science.gov (United States)

    Wang, Hui; Hai, Shan; Cao, Li; Zhou, Jianghua; Liu, Ping; Dong, Bi-Rong

    2016-12-28

    The aim of the present study was to validate the usefulness of the new octapolar multifrequency bioelectrical impedance analysis (BIA) for assessment of appendicular skeletal muscle mass (ASM) by comparing it with that of dual-energy X-ray absorptiometry (DXA) and to investigate the prevalence of sarcopenia in Chinese community-dwelling elderly according to Asian Working Group for Sarcopenia (AWGS) definition. A cross-sectional study was conducted in communities of Chengdu, China. A total of 944 community-dwelling elderly adults aged ≥60 years were included. ASM was measured by using DXA as a criterion method to validate a standing eight-electrode multifrequency BIA (InBody 720), followed by a further estimation of the prevalence of sarcopenia according the AWGS definition. In the Bland-Altman analysis, no significant difference was found between DXA and BIA based on the ASM measurements. The prevalence of AWGS-defined sarcopenia was 12.5% in the elderly women and 8.2% in the elderly men. BIA is suitable for body composition monitoring (ASM) in elderly Chinese as a fast, noninvasive, and convenient method; therefore, it may be a better choice in large epidemiological studies in the Chinese population. The prevalence of AWGS-defined sarcopenia was approximately 10.4% and increased with age in the Chinese community-dwelling elderly in this study.

  5. Prevalence of malnutrition and validation of bioelectrical impedance analysis for the assessment of body composition in patients with systemic sclerosis.

    Science.gov (United States)

    Spanjer, Moon J; Bultink, Irene E M; de van der Schueren, Marian A E; Voskuyl, Alexandre E

    2017-06-01

    The aims were to assess the prevalence of malnutrition and to validate bioelectrical impedance analysis (BIA) against whole-body DXA for the assessment of body composition in patients with SSc. Malnutrition was defined as BMI 10% in combination with a fat-free mass index (FFMI) 70 years). Body composition was assessed in 72 patients with whole-body DXA (Hologic, Discovery A) and BIA (Bodystat Quadscan 400). The manufacturer's equation and the Geneva equation were used to estimate FFM and fat mass. The agreement between BIA and whole-body DXA was assessed with Bland-Altman analysis and intraclass correlation coefficient. Malnutrition was found in 8.3% (n = 6) and low FFMI in 20.8% (n = 15) of patients. The mean difference in FFM between BIA and DXA applying the Geneva equation was 0.02 ( s . d . 2.4) kg, intraclass correlation coefficient 0.97 (95% CI: 0.95, 0.98). Limits of agreement were ±4.6 kg. The manufacturer's equation was less adequate to predict FFM. This study shows a relatively low prevalence of malnutrition in comparison with other studies, but a high prevalence of low FFMI, underlining the necessity of measuring body composition in SSc patients with a standardized and validated method. A good validity of BIA in determining FFM was found at a group level, while at an individual level the FFM may vary by 4.6 kg.

  6. New specific bioelectrical impedance vector reference values for assessing body composition in the Italian-Spanish young adult population.

    Science.gov (United States)

    Ibáñez, Maria E; Mereu, Elena; Buffa, Roberto; Gualdi-Russo, Emanuela; Zaccagni, Luciana; Cossu, Stefano; Rebato, Esther; Marini, Elisabetta

    2015-01-01

    Specific bioelectrical impedance vector analysis (spBIVA) is a recently proposed technique for the analysis of body composition. The aim of this study was to apply spBIVA to a sample of Italian and Spanish young adults and to define the new bioelectrical references for this Western Mediterranean population. A sample of 440 individuals (220 from Italy, 220 from Spain; 213 men, 227 women) aged 18-30 years was considered. Anthropometric (height, weight, relaxed upper arm, waist, and calf girths) and bioelectrical (resistance, reactance; 50 kHz, 800 μA) measurements were taken. In order to verify the need for new references, specific bioelectrical values were compared to the reference values for U.S. adults and Italian elderly by tolerance ellipses and Student's t test. The mean specific bioelectrical values (resistivity, Rsp, and reactivity, Xcsp, Ohm·cm) were: Rsp (332.7 ± 41.7 Ω·cm), Xcsp (44.4 ± 6.8 Ω·cm), Zsp (335.6 ± 41.9 Ω·cm) and phase (7.6 ± 0.8°) in men; Rsp (388.6 ± 60 Ω·cm), Xcsp (43.7 ± 7.5 Ω·cm), Zsp (391.0 ± 60.3 Ω·cm) and phase (6.4 ± 0.7°) in women. Italo-Spanish bioelectrical vectors were mainly distributed (>90%) in the lower part of the tolerance ellipses for U.S. young adults, due to a shorter impedance (P 90%), due to a higher phase (P < 0.001), indicative of higher body cell mass. These population and age-related differences indicate the need for new specific tolerance ellipses that can be used as references for assessing body composition in young adults from Western Mediterranean populations. © 2015 Wiley Periodicals, Inc.

  7. Assessment of body composition using bioelectrical impedance analysis in Prader-Willi syndrome

    Directory of Open Access Journals (Sweden)

    Hsiang-Yu Lin

    2011-11-01

    Full Text Available This study investigated the use of bioelectrical impedance analysis (BIA as a means of assessing body composition in patients with Prader-Willi syndrome (PWS. Segmental, multifrequency BIA was performed on 30 patients with PWS (16 males and 14 females; mean age: 8.1 ± 3.9 years; age range: 2.9–19.6 years using eight tactile electrodes. No patient had received growth hormone treatment prior to baseline measurements. Standard deviation scores for height, weight, and body mass index were –0.96 ± 1.29, 2.28 ± 2.66, and 3.14 ± 2.74, respectively. Percentages of body fat, total body water, and soft lean mass were 45.9 ± 10.8%, 36.6 ± 7.3%, and 49.9 ± 9.9%, respectively. Body fat percentage was positively correlated with the body mass index standard deviation score (r = 0.665, p < 0.01. Follow-up BIA was also performed on five patients who received growth hormone therapy (duration of treatment: 1.5–4.6 years. All of these patients showed reductions in their body fat percentages after treatment. BIA confirmed a significantly higher percentage of body fat in patients with PWS compared with normal children. These findings and the follow-up data can be used to develop quality care strategies for patients with PWS.

  8. A Useful Tool As a Medical Checkup in a General Population—Bioelectrical Impedance Analysis

    Science.gov (United States)

    Enomoto, Mika; Adachi, Hisashi; Fukami, Ako; Kumagai, Eita; Nakamura, Sachiko; Nohara, Yume; Kono, Shoko; Nakao, Erika; Morikawa, Nagisa; Tsuru, Tomoko; Sakaue, Akiko; Fukumoto, Yoshihiro

    2017-01-01

    Accumulation of visceral fat leads to metabolic syndrome and increases risks of cerebro-cardiovascular diseases, which should be recognized and improved at the early stage in general population. Accurate measurement of visceral fat area (VFA) is commonly performed by the abdominal cross-sectional image measured by computed tomography scan, which is, however, limited due to the radiation exposure. The bioelectrical impedance analysis (OMRON, HDS-2000 DUALSCANR) has been recently developed to measure VFA, which is more easily accessible modality. In the present study, we investigated the clinical usefulness of DUALSCANR in 226 subjects who received health examination, including blood chemistries, electrocardiography, cardio, and carotid ultrasonography. VFA was measured within only just 5 min. Average of VFA was 83.5 ± 36.3 cm2 in men, and 64.8 ± 28.0 cm2 in women, which was correlated to weight (r = 0.7404, p < 0.0001), body mass index (BMI) (r = 0.7320, p < 0.0001), and waist circumstance (r = 0.7393, p < 0.0001). In multivariate analyses, VFA was significantly associated with weight (p < 0.0001), BMI (p < 0.0001), and waist circumstance (p < 0.0001). Compared to the group of smaller waist and normal BMI, VFA was significantly increased (p < 0.0001) in the group of larger waist and obese subjects. In conclusion, these results indicated that DUALSCANR is useful to measure VFA easily in general population, even in a large number of subjects. PMID:28210619

  9. Tracking of anthropometric parameters and bioelectrical impedance in pubertal boys and girls.

    Science.gov (United States)

    Leppik, Aire; Jürimäe, Toivo; Jürimäe, Jaak

    2006-12-01

    The aim of this study was to investigate the anthropometric parameters and body impedance once per year during four years of the pubertal period in Estonian children. In total, 81 boys and 86 girls aged 10-11 years at the beginning of the study were investigated. Pubertal status was self-assessed by sexual maturation stages according to Tanner and physical activity index (PAI) according to Telama et al.. Body height and weight were measured and body mass index (BMI) calculated. In total, 9 skinfolds, 13 girths, 8 lengths and 8 breadths/lengths were measured according to the protocol of the International Society for the Advancement of Kinanthropometry. Somatotype components were estimated according to the method of Carter and Heath. Body impedance was measured using Multiscan 5000 (Bodystat, UK) and the impedance index (height/impedance) was calculated. The tracking of body height, weight, BMI, skinfolds, girths, lengths, breadth/lengths and body impedance was high (as a rule r> or =0.9). By increasing the time period, the correlation slightly decreased. In contrast, tracking correlations for PAI and Tanner stages were significant but quite low. Increase in mean body height was highest between 12-13 years of age (6.9 cm per year) in boys and in girls between 11-12 years of age (6.3 cm per year). In boys and girls, the peak increase in body weight was between 11 and 12 years of age, 5.7 kg and 5.2 kg, respectively. With the increasing age, body impedance decreased and impedance index increased. In conclusion, our results indicate that during puberty the detailed anthropometric parameters and body impedance tracked highly. However, the tracking of PAI and Tanner stages was significant but relatively low.

  10. Bias and limits of agreement between hydrodensitometry, bioelectrical impedance and skinfold calipers measures of percentage body fat.

    Science.gov (United States)

    Williams, C A; Bale, P

    1998-02-01

    Previous research has often used correlations as a statistical method to show agreement; however, this is not a valid use of the statistic. The purpose of this study was to investigate the bias and limits of agreement for three methods of estimating percentage body fat for 117 male and 114 female university athletes: hydrodensitometry (HYD), bioelectrical impedance (BIA) and skinfold calipers (SKF). The mean (SD) percentage body fat for males as assessed by HYD, BIA and SKF methods, respectively, were 13.2 (3.3)%, 14.1, (3.3)% and 13.0 (3.2)%. Female body fat measurements were 22.5 (3.9)%, 23.7 (4.3)% and 23.8 (4.2)%, respectively. Pearson product moment correlations for male and female body fat percentages between the three methods were high, ranging from 0.81 to 0.86 (P < 0.05). However, compared to the criterion measure of body fat percentage (HYD), the magnitude of agreement BIA and SKF revealed a different pattern. The mean absolute difference between HYD and BIA measurements of body fat for males was -0.8 (2.0)% fat, and between HYD and SKF was it was 0.2 (1.7)% fat. The mean absolute difference for females between HYD and BIA was -1.2 (2.5)%; for HYD and SKF it was -1.4 (2.2)%. Compared to the HYD measures for males and females, the BIA and SKF measures were as much as a 3.8% underestimation and a 6.2% overestimation of body fat. This study provides evidence that the strength of a correlation does not indicate agreement between two methods. In future, reliability and validity studies should examine the absolute differences between two variables and calculate limits of agreement around which a practitioner can appreciate the precision of the methodologies.

  11. Comparison of Standing Posture Bioelectrical Impedance Analysis with DXA for Body Composition in a Large, Healthy Chinese Population

    Science.gov (United States)

    Chen, Kuen-Tsann; Chen, Yu-Yawn; Wang, Chia-Wei; Chuang, Chih-Lin; Chiang, Li-Ming; Lai, Chung-Liang; Lu, Hsueh-Kuan; Dwyer, Gregory B.; Chao, Shu-Ping; Shih, Ming-Kuei; Hsieh, Kuen-Chang

    2016-01-01

    Bioelectrical impedance analysis (BIA) is a common method for assessing body composition in research and clinical trials. BIA is convenient but when compared with other reference methods, the results have been inconclusive. The level of obesity degree in subjects is considered to be an important factor affecting the accuracy of the measurements. A total of 711 participants were recruited in Taiwan and were sub-grouped by gender and levels of adiposity. Regression analysis and Bland-Altman analysis were used to evaluate the agreement of the measured body fat percentage (BF%) between BIA and DXA. The BF% measured by the DXA and BIA methods (Tanita BC-418) were expressed as BF%DXA and BF%BIA8, respectively. A one-way ANOVA was used to test the differences in BF% measurements by gender and levels of adiposity. The estimated BF%BIA8 and BF%DXA in the all subjects, male and female groups were all highly correlated (r = 0.934, 0.901, 0.916, all P< 0.001). The average estimated BF%BIA8 (22.54 ± 9.48%) was significantly lower than the average BF%DXA (26.26 ± 11.18%). The BF%BIA8 was overestimated in the male subgroup (BF%DXA< 15%), compared to BF%DXA by 0.45%, respectively. In the other subgroups, the BF%BIA8 values were all underestimated. Standing BIA estimating body fat percentage in Chinese participants have a high correlation, but underestimated on normal and high obesity degree in both male and female subjects. PMID:27467065

  12. Assessment of body composition with bioelectrical impedance analysis in pregnant women with hyperemesis gravidarum before and after treatment.

    Science.gov (United States)

    Tazegül Pekin, A; Yılmaz, S A; Kerimoğlu, Ö Seçilmiş; Çelik, G; Doğan, N U; Beyhekim, H; Çelik, Ç

    2015-01-01

    More than half of pregnant women suffer from nausea and vomiting, in 0.5-1% of the pregnant women, if nausea and vomiting are severe and persistent, condition can progress to hyperemesis. We evaluated the fluid volume parameters in pregnant women with hyperemesis gravidarum, before and after treatment using the bioelectrical impedance vectors. A total of 70 pregnant women who had weight loss exceeding 5% of pre-pregnancy body weight were recruited for the study in the first trimester. The measurement of multi-frequency bioelectrical impedance analysis parameters was performed on the day of hospitalisation before any treatment and after treatment at 24 h and 72 h with the same procedure. Total body water, extracellular water, intracellular water, and fat-free mass index increased after treatment at 24 h (P treatment (11.3 ± 2.1 at enrolment, 5.1 ± 1.4 at 24 h and 4.3 ± 1.1 at 72 h) (P hyperemesis gravidarum, significant body composition changes occur and fluid replacement therapy performed during a short period of time, such as 24 h, provides improvement in body composition.

  13. Nutritional status and body composition by bioelectrical impedance vector analysis: A cross sectional study in mild cognitive impairment and Alzheimer’s disease

    Science.gov (United States)

    Pomati, Simone; Maggiore, Laura; Forcella, Marica; Cucumo, Valentina; Ghiretti, Roberta; Grande, Giulia; Muzio, Fulvio; Mariani, Claudio

    2017-01-01

    Aims Analysis of nutritional status and body composition in Alzheimer’s disease (AD) and Mild Cognitive Impairment (MCI). Methods A cross-sectional study was performed in a University-Hospital setting, recruiting 59 patients with AD, 34 subjects with MCI and 58 elderly healthy controls (HC). Nutritional status was assessed by anthropometric parameters (body mass index; calf, upper arm and waist circumferences), Mini Nutritional Assessment (MNA) and body composition by bioelectrical impedance vector analysis (BIVA). Variables were analyzed by analysis of variance and subjects were grouped by cognitive status and gender. Results Sociodemographic variables did not differ among the three groups (AD, MCI and HC), except for females’ age, which was therefore used as covariate in a general linear multivariate model. MNA score was significantly lower in AD patients than in HC; MCI subjects achieved intermediate scores. AD patients (both sexes) had significantly (p<0.05) higher height-normalized impedance values and lower phase angles (body cell mass) compared with HC; a higher ratio of impedance to height was found in men with MCI with respect to HC. With BIVA method, MCI subjects showed a significant displacement on the RXc graph on the right side indicating lower soft tissues (Hotelling’s T2 test: men = 10.6; women = 7.9;p < 0,05) just like AD patients (Hotelling’s T2 test: men = 18.2; women = 16.9; p<0,001). Conclusion Bioelectrical parameters significantly differ from MCI and AD to HC; MCI showed an intermediate pattern between AD and HC. Longitudinal studies are required to investigate if BIVA could reflect early AD-changes in body composition in subjects with MCI. PMID:28187148

  14. Reliability of Calf Bioelectrical Impedance Spectroscopy and Magnetic-Resonance-Imaging-Acquired Skeletal Muscle Hydration Measures in Healthy People

    Directory of Open Access Journals (Sweden)

    Anuradha Sawant

    2013-01-01

    Full Text Available Purpose. The purpose of this study was to investigate the test-retest reliability, relative variability, and agreement between calf bioelectrical impedance-spectroscopy (cBIS acquired extracellular fluid (ECF, intracellular fluid (ICF, total water and the ratio of ECF : ICF, magnetic-resonance-imaging (MRI acquired transverse relaxation times (T2, and apparent diffusion coefficient (ADC of calf muscles of the same segment in healthy individuals. Methods. Muscle hydration measures were collected in 32 healthy individuals on two occasions and analyzed by a single rater. On both occasions, MRI measures were collected from tibialis anterior (TA, medial (MG, and lateral gastrocnemius (LG and soleus muscles following the cBIS data acquired using XiTRON Hydra 4200 BIS device. The intraclass correlation coefficients (ICC2,1, coefficient of variation (CV, and agreement between MRI and cBIS data were also calculated. Results. ICC2,1 values for cBIS, T2, and ADC ranged from 0.56 to 0.92, 0.96 to 0.99, and 0.05 to 0.56, respectively. Relative variability between measures (CV ranged from 14.6 to 25.6% for the cBIS data and 4.2 to 10.0% for the MRI-acquired data. The ratio of ECF : ICF could significantly predict T2 of TA and soleus muscles. Conclusion. MRI-acquired measures of T2 had the highest test-retest reliability of muscle hydration with the least error and variation on repeated testing. Hence, T2 of a muscle is the most reliable and stable outcome measure for evaluating individual muscle hydration.

  15. Validity of segmental bioelectrical impedance analysis for estimating fat-free mass in children including overweight individuals.

    Science.gov (United States)

    Ohta, Megumi; Midorikawa, Taishi; Hikihara, Yuki; Masuo, Yoshihisa; Sakamoto, Shizuo; Torii, Suguru; Kawakami, Yasuo; Fukunaga, Tetsuo; Kanehisa, Hiroaki

    2017-02-01

    This study examined the validity of segmental bioelectrical impedance (BI) analysis for predicting the fat-free masses (FFMs) of whole-body and body segments in children including overweight individuals. The FFM and impedance (Z) values of arms, trunk, legs, and whole body were determined using a dual-energy X-ray absorptiometry and segmental BI analyses, respectively, in 149 boys and girls aged 6 to 12 years, who were divided into model-development (n = 74), cross-validation (n = 35), and overweight (n = 40) groups. Simple regression analysis was applied to (length)(2)/Z (BI index) for each of the whole-body and 3 segments to develop the prediction equations of the measured FFM of the related body part. In the model-development group, the BI index of each of the 3 segments and whole body was significantly correlated to the measured FFM (R(2) = 0.867-0.932, standard error of estimation = 0.18-1.44 kg (5.9%-8.7%)). There was no significant difference between the measured and predicted FFM values without systematic error. The application of each equation derived in the model-development group to the cross-validation and overweight groups did not produce significant differences between the measured and predicted FFM values and systematic errors, with an exception that the arm FFM in the overweight group was overestimated. Segmental bioelectrical impedance analysis is useful for predicting the FFM of each of whole-body and body segments in children including overweight individuals, although the application for estimating arm FFM in overweight individuals requires a certain modification.

  16. Prediction of fat-free body mass from bioelectrical impedance among 9- to 11-year-old Swedish children

    DEFF Research Database (Denmark)

    Nielsen, Birgit Marie; Dencker, M; Ward, L

    2007-01-01

    AIM: Predictive equations for estimating body composition from bioelectrical impedance analysis (BIA) among Scandinavian children are lacking. In the present study, equations for estimation of fat-free body mass (FFM) and lean tissue mass (LTM) were developed and cross-validated from BIA using dual......-validation revealed a mean RMSE = 0.95 kg FFM and a mean RMSE = 0.96 kg LTM. Prediction of body composition from equations developed in previous literature was mixed when applied to the present cohort of children. CONCLUSIONS: FFM and LTM are predicted with sufficient accuracy at the population level. We recommend...... that the predictive equations developed in the present study are used in prepubescent European children aged 9-11 years only in order to minimize confounding of results because of possible differences in population samples....

  17. Measuring body composition in dogs using multifrequency bioelectrical impedance analysis and dual energy X-ray absorptiometry.

    Science.gov (United States)

    Rae, L S; Vankan, D M; Rand, J S; Flickinger, E A; Ward, L C

    2016-06-01

    Thirty-five healthy, neutered, mixed breed dogs were used to determine the ability of multifrequency bioelectrical impedance analysis (MFBIA) to predict accurately fat-free mass (FFM) in dogs using dual energy X-ray absorptiometry (DXA)-measured FFM as reference. A second aim was to compare MFBIA predictions with morphometric predictions. MFBIA-based predictors provided an accurate measure of FFM, within 1.5% when compared to DXA-derived FFM, in normal weight dogs. FFM estimates were most highly correlated with DXA-measured FFM when the prediction equation included resistance quotient, bodyweight, and body condition score. At the population level, the inclusion of impedance as a predictor variable did not add substantially to the predictive power achieved with morphometric variables alone; in individual dogs, impedance predictors were more valuable than morphometric predictors. These results indicate that, following further validation, MFBIA could provide a useful tool in clinical practice to objectively measure FFM in canine patients and help improve compliance with prevention and treatment programs for obesity in dogs.

  18. Performance of Two Bioelectrical Impedance Analyses in the Diagnosis of Overweight and Obesity in Children and Adolescents: The FUPRECOL Study

    Science.gov (United States)

    Ramírez-Vélez, Robinson; Correa-Bautista, Jorge Enrique; Martínez-Torres, Javier; González-Ruíz, Katherine; González-Jiménez, Emilio; Schmidt-RioValle, Jacqueline; Garcia-Hermoso, Antonio

    2016-01-01

    This study aimed to determine thresholds for percentage of body fat (BF%) corresponding to the cut-off values for overweight/obesity as recommended by the International Obesity Task Force (IOTF), using two bioelectrical impedance analyzers (BIA), and described the likelihood of increased cardiometabolic risk in our cohort defined by the IOTF and BF% status. Participants included 1165 children and adolescents (54.9% girls) from Bogotá (Colombia). Body mass index (BMI) was calculated from height and weight. BF% of each youth was assessed first using the Tanita BC-418® followed by a Tanita BF-689®. The sensitivity and specificity of both devices and their ability to correctly classify children as overweight/obesity (≥2 standard deviation), as defined by IOTF, was investigated using receiver operating characteristic (ROC) by sex and age groups (9–11, 12–14, and 13–17 years old); Area under curve (AUC) values were also reported. For girls, the optimal BF% threshold for classifying into overweight/obesity was found to be between 25.2 and 28.5 (AUC = 0.91–0.97) and 23.9 to 26.6 (AUC = 0.90–0.99) for Tanita BC-418® and Tanita BF-689®, respectively. For boys, the optimal threshold was between 16.5 and 21.1 (AUC = 0.93–0.96) and 15.8 to 20.6 (AUC = 0.92–0.94) by Tanita BC-418® and Tanita BF-689®, respectively. All AUC values for ROC curves were statistically significant and there were no differences between AUC values measured by both BIA devices. The BF% values associated with the IOTF-recommended BMI cut-off for overweight/obesity may require age- and sex-specific threshold values in Colombian children and adolescents aged 9–17 years and could be used as a surrogate method to identify individuals at risk of excess adiposity. PMID:27782039

  19. Performance of Two Bioelectrical Impedance Analyses in the Diagnosis of Overweight and Obesity in Children and Adolescents: The FUPRECOL Study

    Directory of Open Access Journals (Sweden)

    Robinson Ramírez-Vélez

    2016-10-01

    Full Text Available This study aimed to determine thresholds for percentage of body fat (BF% corresponding to the cut-off values for overweight/obesity as recommended by the International Obesity Task Force (IOTF, using two bioelectrical impedance analyzers (BIA, and described the likelihood of increased cardiometabolic risk in our cohort defined by the IOTF and BF% status. Participants included 1165 children and adolescents (54.9% girls from Bogotá (Colombia. Body mass index (BMI was calculated from height and weight. BF% of each youth was assessed first using the Tanita BC-418® followed by a Tanita BF-689®. The sensitivity and specificity of both devices and their ability to correctly classify children as overweight/obesity (≥2 standard deviation, as defined by IOTF, was investigated using receiver operating characteristic (ROC by sex and age groups (9–11, 12–14, and 13–17 years old; Area under curve (AUC values were also reported. For girls, the optimal BF% threshold for classifying into overweight/obesity was found to be between 25.2 and 28.5 (AUC = 0.91–0.97 and 23.9 to 26.6 (AUC = 0.90–0.99 for Tanita BC-418® and Tanita BF-689®, respectively. For boys, the optimal threshold was between 16.5 and 21.1 (AUC = 0.93–0.96 and 15.8 to 20.6 (AUC = 0.92–0.94 by Tanita BC-418® and Tanita BF-689®, respectively. All AUC values for ROC curves were statistically significant and there were no differences between AUC values measured by both BIA devices. The BF% values associated with the IOTF-recommended BMI cut-off for overweight/obesity may require age- and sex-specific threshold values in Colombian children and adolescents aged 9–17 years and could be used as a surrogate method to identify individuals at risk of excess adiposity.

  20. Influence of Posture and Frequency Modes in Total Body Water Estimation Using Bioelectrical Impedance Spectroscopy in Boys and Adult Males

    Directory of Open Access Journals (Sweden)

    Masaharu Kagawa

    2014-05-01

    Full Text Available The aim of the study was to examine differences in total body water (TBW measured using single-frequency (SF and multi-frequency (MF modes of bioelectrical impedance spectroscopy (BIS in children and adults measured in different postures using the deuterium (2H dilution technique as the reference. Twenty-three boys and 26 adult males underwent assessment of TBW using the dilution technique and BIS measured in supine and standing positions using two frequencies of the SF mode (50 kHz and 100 kHz and the MF mode. While TBW estimated from the MF mode was comparable, extra-cellular fluid (ECF and intra-cellular fluid (ICF values differed significantly (p < 0.01 between the different postures in both groups. In addition, while estimated TBW in adult males using the MF mode was significantly (p < 0.01 greater than the result from the dilution technique, TBW estimated using the SF mode and prediction equation was significantly (p < 0.01 lower in boys. Measurement posture may not affect estimation of TBW in boys and adult males, however, body fluid shifts may still occur. In addition, technical factors, including selection of prediction equation, may be important when TBW is estimated from measured impedance.

  1. On Chip Bioelectric Impedance Spectroscopy Reveals the Effect of P-Glycoprotein Efflux Pumps on the Paracellular Impedance of Tight Junctions at the Blood-Brain Barrier.

    Science.gov (United States)

    Kraya, Ramsey; Komin, Alexander; Searson, Peter

    2016-10-01

    Bioelectric impedance spectroscopy was used to elucidate the influence of P-gp efflux pumps on the kinetics of tight junction down-regulation in confluent monolayers of Madine Darby Canine Kidney Epithelial Cells (MDCK) following administration of phenylarsine oxide (PAO), a molecule that inhibits protein tyrosine phosphatases (PTP) and induces matrix metalloproteinase activity. Matrix metalloproteinases (MMPs) and phosphatase inhibitors induce modification of occludin tight junction proteins critical for the proper function of the blood-brain barrier. The addition of PAO to MDCKII cell lines resulted in a dramatic decrease in monolayer resistance. In contrast, MDCKII-MDR1 cells transfected with the MDR1 gene treated with PAO showed an initial decrease in monolayer resistance followed by a partial recovery and subsequent decrease. This resistance decay reversal was suppressed with the addition of the P-glycoprotein (P-gp) pump inhibitor elacridar, and is attributed to PAO efflux. These results illustrate impedance spectroscopy can be used to characterize the competing kinetics of efflux and down-regulation of tight junctions. In addition, the resistance decay reversal effect can be used to evaluate P-gp pump inhibitor efficacy.

  2. Preliminary bioelectrical impedance analysis (BIA) equation for body composition assessment in young females from Colombia

    Science.gov (United States)

    Caicedo-Eraso, J. C.; González-Correa, C. H.; González-Correa, C. A.

    2013-04-01

    A previous study showed that reported BIA equations for body composition are not suitable for Colombian population. The purpose of this study was to develop and validate a preliminary BIA equation for body composition assessment in young females from Colombia, using hydrodensitometry as reference method. A sample of 30 young females was evaluated. Inclusion and exclusion criteria were defined to minimize the variability of BIA. Height, weight, BIA, residual lung volume (RV) and underwater weight (UWW) were measured. A preliminary BIA equation was developed (r2 = 0.72, SEE = 2.48 kg) by stepwise multiple regression with fat-free mass (FFM) as dependent variable and weight, height and impedance measurements as independent variables. The quality of regression was evaluated and a cross-validation against 50% of sample confirmed that results obtained with the preliminary BIA equation is interchangeable with results obtained with hydrodensitometry (r2 = 0.84, SEE = 2.62 kg). The preliminary BIA equation can be used for body composition assessment in young females from Colombia until a definitive equation is developed. The next step will be increasing the sample, including a second reference method, as deuterium oxide dilution (D2O), and using multi-frequency BIA (MF-BIA). It would also be desirable to develop equations for males and other ethnic groups in Colombia.

  3. Biochemical and anthropometric correlates of bio-electrical impedance parameters in severely malnourished children

    DEFF Research Database (Denmark)

    Girma, Tsinuel; Nielsen, Anne-Louise Hother; Kæstel, Pernille

    2017-01-01

    INTRODUCTION: Despite expanding use of bio-impedance (BI), little is known about its pathophysiologic significance and biological correlates OBJECTIVE: Determine correlations of BI parameters with anthropometry and biomarkers of electrolyte homeostasis, inflammation and liver function in children...

  4. VALIDITY OF BODY DENSITY WITH METHODS OF BODY MASS INDEX, SKIN FOLD, BIO- ELECTRICAL IMPEDANCE & CRITERION METHOD OF HYDROSTATIC IN MEN ATHLETES OF SWIMMING

    Directory of Open Access Journals (Sweden)

    M Bayat KASHKOLİ

    2011-12-01

    Full Text Available The goal of present research is estimating and validity of body density with methods of Body Mass Index, Skin Fold, Bio-Electrical Impedance and Criterion Method of Hydrostatic in men athletes of swimming. The present research has been conducted with semi-experimental and functional method. For doing so 25 men swimming athletes were randomly selected (N= 120. Statistical analysis was conducted with Pearson coefficient, correlated T-test, TE & SEE. The results of statistical analysis show that the method of Skin Fold Stat with hydrostatic criterion method has meaningful difference in society of swimmers. Also there is meaningful difference between body mass index and criterion method. There was not any meaningful difference between bio-electrical impedance and criterion method in swimmers. (TE=3.01, SEE=2.91, R=0.924, P=0.064. The findings show that that bio-electrical impedance in swimmer athletes is more suitable method.

  5. Effect of the ethinylestradiol/norelgestromin contraceptive patch on body composition. Results of bioelectrical impedance analysis in a population of Italian women

    Directory of Open Access Journals (Sweden)

    Bruni Vincenzina

    2008-08-01

    Full Text Available Abstract Background As weight gain is one of the most frequently cited reasons for not using and for discontinuing hormonal contraceptives, in an open-label, single-arm, multicentre clinical study we evaluated the effect of the ethinylestradiol/norelgestromin contraceptive patch (EVRA, Janssen-Cilag International, Belgium on body composition using bioelectrical impedance analysis (BIA. Methods Body weight and impedance vector components (resistance (R and reactance (Xc, at 50 kHz frequency, Akern-RJL Systems analyzer were recorded before entry, after 1, 3 and 6 months in 182 Italian healthy women aged 29 yr (18 to 45, and with BMI 21.8 kg/m2 (16 to 31. Total body water (TBW was estimated with a BIA regression equation. Vector BIA was performed with the RXc mean graph method and the Hotelling's T2 test for paired and unpaired data. Results After 6 months body weight increased by 0.64 kg (1.1% and TBW increased by 0.51 L (1.7%. The pattern of impedance vector displacement indicated a small increase in soft tissue hydration (interstitial gel fluid. Body composition changes did not significantly differ among groups of previous contraceptive methods. Arterial blood pressure did not significantly change over time. Conclusion After 6 months of treatment with the ethinylestradiol/norelgestromin contraceptive patch we found a minimal, clinically not relevant, increase in body weight less than 1 kg that could be attributed to an adaptive interstitial gel hydration. This fluctuation is physiological as confirmed by the lack of any effect on blood pressure. This could be useful in increasing women's choice, acceptability and compliance of the ethinylestradiol/norelgestromin contraceptive patch.

  6. Phase Angle of Bioelectrical Impedance Analysis as Prognostic Factor in Palliative Care Patients at the National Cancer Institute in Mexico.

    Science.gov (United States)

    Pérez Camargo, Dana A; Allende Pérez, Silvia R; Rivera Franco, Mónica M; Álvarez Licona, Nelson E; Urbalejo Ceniceros, Víctor I; Figueroa Baldenegro, Lilian E

    2017-01-01

    Patients with advanced cancer often experience symptoms of disease and treatment that contribute to distress such as weight loss, which is present in up to 85% of cancer patients. Palliative care in these patients focuses on care aimed at improving quality of life. Phase angle (PA) is obtained by bioelectric impedance analysis (BIA) and is associated with cellular function. It is considered a reliable marker of malnutrition. A low PA may suggest deterioration of the cell membrane, which in palliative patients may result in a short-term survival. The aim of this study was to associate PA and survival in palliative patients of the National Cancer Institute of Mexico. We included 452 patients (women, 56.4%); the average PA was 4.0°. The most frequent disease was gastric cancer (39.2%). Mean body mass index (BMI) was 22.84. The average survival of patients with PA ≤ 4° was 86 days, while in the group with PA > 4°, it was 163 days (P > 0.0001). PA showed significant positive correlation with survival time and BMI. Our results corroborate the reliability of PA in Mexican population, as an indicator of survival in palliative care patients compared to the reported literature in other countries.

  7. The accuracy of hand-to-hand bioelectrical impedance analysis in predicting body composition in college-age female athletes.

    Science.gov (United States)

    Esco, Michael R; Olson, Michele S; Williford, Henry N; Lizana, Suheil N; Russell, Angela R

    2011-04-01

    The purpose of this investigation was to determine the accuracy of hand-to-hand bioelectrical impedance analysis (BIA) for estimating body composition in college-age female athletes using dual-energy X-ray absorptiometry (DEXA) as the criterion measure. Forty National Association for Intercollegiate Athletics college female athletes volunteered to participate in this study. For each participant, total body fat percentage (BF%) and fat-free mass (FFM) were obtained via BIA and DEXA. The mean BF% and FFM values obtained by BIA were compared with the criterion DEXA measure. The DEXA strongly correlated to the BIA for BF% (r = 0.74, R2 = 0.55, SEE = 3.60, and p < 0.01) and FFM (r = 0.84, R2 = 0.71, SEE = 2.45, p < 0.01). However, when compared with the DEXA, the mean values for BIA were significantly lower for BF% (DEXA = 27.6 ± 5.3%, BIA = 22.5 ± 3.5%, p < 0.01) and higher for FFM (DEXA = 47.2 ± 4.5 kg, BIA = 50.6 ± 4.6 kg, p < 0.01). The results of this investigation indicate that hand-to-hand BIA significantly underestimates BF% and overestimated FFM in college-age female athletes when compared with the criterion DEXA. Practitioners should use caution when analyzing body composition with hand-held BIA in a population of athletic women.

  8. Body composition of adult cystic fibrosis patients and control subjects as determined by densitometry, bioelectrical impedance, total-body electrical conductivity, skinfold measurements, and deuterium oxide dilution

    Energy Technology Data Exchange (ETDEWEB)

    Newby, M.J.; Keim, N.L.; Brown, D.L. (Univ. of California, Davis (USA))

    1990-08-01

    This study contrasts body compositions (by six methods) of eight cystic fibrosis (CF) subjects with those of eight control subjects matched for age, height, and sex. CF subjects weighed 84% as much as control subjects. Densitometry and two bioelectrical impedance-analysis methods suggested that reduced CF weights were due to less lean tissue (10.7, 9.5, and 10.4 kg). Total-body electrical conductivity (TOBEC) and skinfold-thickness measurements indicated that CF subjects were leaner than control subjects and had less fat (5.4 and 3.6 kg) and less lean (5.2 and 7 kg) tissue. D2O dilution showed a pattern similar to TOBEC (8.3 kg less lean, 2.7 kg less fat tissue). Densitometry estimates of fat (mass and percent) were not correlated (r less than 0.74, p greater than 0.05) with any other method for CF subjects but were correlated with all other methods for control subjects. CF subjects contained less fat and lean tissue than did control subjects. Densitometry by underwater weighing is unsuitable for assessing body composition of CF patients.

  9. Bioelectrical impedance spectroscopy as a fluid management system in heart failure.

    Science.gov (United States)

    Weyer, Sören; Zink, Matthias Daniel; Wartzek, Tobias; Leicht, Lennart; Mischke, Karl; Vollmer, Thomas; Leonhardt, Steffen

    2014-06-01

    Episodes of hospitalization for heart failure patients are frequent and are often accompanied by fluid accumulations. The change of the body impedance, measured by bioimpendace spectroscopy, is an indicator of the water content. The hypothesis was that it is possible to detect edema from the impedance data. First, a finite integration technique was applied to test the feasibility and allowed a theoretical analysis of current flows through the body. Based on the results of the simulations, a clinical study was designed and conducted. The segmental impedances of 25 patients suffering from heart failure were monitored over their recompensation process. The mean age of the patients was 73.8 and their mean body mass index was 28.6. From these raw data the model parameters from the Cole model were deduced by an automatic fitting algorithm. These model data were used to classify the edema status of the patient. The baseline values of the regression lines of the extra- and intracellular resistance from the transthoracic measurement and the baseline value of the regression line of the extracellular resistance from the foot-to-foot measurement were identified as important parameters for the detection of peripheral edema. The rate of change of the imaginary impedance at the characteristic frequency and the mean intracellular resistance from the foot-to-foot measurement were identified as important parameters for the detection of pulmonary edema. To classify the data, two decision trees were considered: One should detect pulmonary edema (n(pulmonary) = 13, n(none) = 12) and the other peripheral edema (n(peripheral) = 12, n(none) = 13). Peripheral edema could be detected with a sensitivity of 100% and a specificity of 90%. The detection of pulmonary edema showed a sensitivity of 92.31% and a specificity of 100%. The leave-one-out cross-validation-error for the peripheral edema detection was 12% and 8% for the detection of pulmonary edema. This enables the application of BIS as

  10. Validity of Standing Posture Eight-electrode Bioelectrical Impedance to Estimate Body Composition in Taiwanese Elderly

    Directory of Open Access Journals (Sweden)

    Ling-Chun Lee

    2014-09-01

    Conclusion: The results of this study showed that the impedance index and LST in the whole body, upper limbs, and lower limbs derived from DXA findings were highly correlated. The LST and BF% estimated by BIA8 in whole body and various body segments were highly correlated with the corresponding DXA results; however, BC-418 overestimates the participants' appendicular LST and underestimates whole body BF%. Therefore, caution is needed when interpreting the results of appendicular LST and whole body BF% estimated for elderly adults.

  11. The performance of integrated transconductance amplifiers as variable current sources for bio-electric impedance measurements.

    Science.gov (United States)

    Smith, D N

    1992-01-01

    Multiple applied current impedance measurement systems require numbers of current sources which operate simultaneously at the same frequency and within the same phase but at variable amplitudes. Investigations into the performance of some integrated operational transconductance amplifiers as variable current sources are described. Measurements of breakthrough, non-linearity and common-mode output levels for LM13600, NE5517 and CA3280 were carried out. The effects of such errors on the overall performance and stability of multiple current systems when driving floating loads are considered.

  12. Body composition by bioelectrical-impedance analysis compared with deuterium dilution and skinfold anthropometry in patients with chronic obstructive pulmonary disease

    Energy Technology Data Exchange (ETDEWEB)

    Schols, A.M.; Wouters, E.F.; Soeters, P.B.; Westerterp, K.R. (Univ. of Limburg, Maastricht (Netherlands))

    1991-02-01

    Body composition is an important measure of nutritional status in patients with chronic obstructive pulmonary disease (COPD). We generated a regression model for bioelectrical impedance (BI) by using deuterium dilution (2H2O) as a reference method in 32 COPD patients, aged 63 +/- 9 y (mean +/- SD), in stable pulmonary and cardiac condition. Height squared divided by resistance (Ht2/Res) correlated well with total body water (TBW) as measured by 2H2O (r = 0.93, P less than 0.001, SEE = 1.9 L). The best-fitting regression equation to predict TBW comprised Ht2/Res and body weight (r2 = 0.89, SEE = 1.8 L, P less than 0.001). BI-predicted TBW was used to estimate BI-fat-free mass (FFM) that was compared with skinfold-thickness-based FFM predictions (Anthr-FFM). Relative to BI-FFM a significant overestimation of 4.4 +/- 0.8 kg was found by Anthr-FFM. Our results suggest that BI is a useful measure of body composition in patients with severe COPD.

  13. The investigation of the some body parameters of obese and (obese+diabetes) patients with using bioelectrical impedance analysis techniques

    Science.gov (United States)

    Yerlikaya, Emrah; Karageçili, Hasan; Aydin, Ruken Zeynep

    2016-04-01

    Obesity is a key risk for the development of hyperglycemia, hypertension, hyperlipidemia, insulin resistance and is totally referred to as the metabolic disorders. Diabetes mellitus, a metabolic disorder, is related with hyperglycemia, altered metabolism of lipids, carbohydrates and proteins. The minimum defining characteristic feature to identify diabetes mellitus is chronic and substantiated elevation of circulating glucose concentration. In this study, it is aimed to determine the body composition analyze of obese and (obese+diabetes) patients.We studied the datas taken from three independent groups with the body composition analyzer instrument. The body composition analyzer calculates body parameters, such as body fat ratio, body fat mass, fat free mass, estimated muscle mass, and base metabolic rate on the basis of data obtained by Dual Energy X-ray Absorptiometry using Bioelectrical Impedance Analysis. All patients and healthy subjects applied to Siirt University Medico and their datas were taken. The Statistical Package for Social Sciences version 21 was used for descriptive data analysis. When we compared and analyzed three groups datas, we found statistically significant difference between obese, (obese+diabetes) and control groups values. Anova test and tukey test are used to analyze the difference between groups and to do multiple comparisons. T test is also used to analyze the difference between genders. We observed the statistically significant difference in age and mineral amount peducation level among the illiterate and university graduates; fat mass kg, fat percentage, internal lubrication, body mass index, water percentage, protein mass percentage, mineral percentage p<0.05, significant statistically difference were observed. This difference especially may result of a sedentary lifestyle.

  14. Phase angle assessment by bioelectrical impedance analysis and its predictive value for malnutrition risk in hospitalized geriatric patients.

    Science.gov (United States)

    Varan, Hacer Dogan; Bolayir, Basak; Kara, Ozgur; Arik, Gunes; Kizilarslanoglu, Muhammet Cemal; Kilic, Mustafa Kemal; Sumer, Fatih; Kuyumcu, Mehmet Emin; Yesil, Yusuf; Yavuz, Burcu Balam; Halil, Meltem; Cankurtaran, Mustafa

    2016-12-01

    Phase angle (PhA) value determined by bioelectrical impedance analysis (BIA) is an indicator of cell membrane damage and body cell mass. Recent studies have shown that low PhA value is associated with increased nutritional risk in various group of patients. However, there have been only a few studies performed globally assessing the relationship between nutritional risk and PhA in hospitalized geriatric patients. The aim of the study is to evaluate the predictive value of the PhA for malnutrition risk in hospitalized geriatric patients. One hundred and twenty-two hospitalized geriatric patients were included in this cross-sectional study. Comprehensive geriatric assessment tests and BIA measurements were performed within the first 48 h after admission. Nutritional risk state of the patients was determined with NRS-2002. Phase angle values of the patients with malnutrition risk were compared with the patients that did not have the same risk. The independent variables for predicting malnutrition risk were determined. SPSS version 15 was utilized for the statistical analyzes. The patients with malnutrition risk had significantly lower phase angle values than the patients without malnutrition risk (p = 0.003). ROC curve analysis suggested that the optimum PhA cut-off point for malnutrition risk was 4.7° with 79.6 % sensitivity, 64.6 % specificity, 73.9 % positive predictive value, and 73.9 % negative predictive value. BMI, prealbumin, PhA, and Mini Mental State Examination Test scores were the independent variables for predicting malnutrition risk. PhA can be a useful, independent indicator for predicting malnutrition risk in hospitalized geriatric patients.

  15. A comparison of fat mass and skeletal muscle mass estimation in male ultra-endurance athletes using bioelectrical impedance analysis and different anthropometric methods Comparación de la masa grasa y muscular estimada en atletas varones de ultra-resistencia utilizando la bioimpedancia eléctrica y diferentes métodos antropométricos

    Directory of Open Access Journals (Sweden)

    B. Knechtle

    2011-12-01

    Full Text Available Two hundred and fifty seven male Caucasian ultraendurance athletes were recruited, pre-race, before different swimming, cycling, running and triathlon races. Fat mass and skeletal muscle mass were estimated using bioelectrical impedance analysis (BIA and anthropometric methods in order to investigate whether the use of BIA or anthropometry would be useful under field conditions. Total body fat estimated using BIA was significantly high (P Se reclutaron a 257 hombres caucasianos que eran atletas de alto rendimiento, antes de competir en diferentes pruebas triatlón de natación, ciclismo y carrera. Se estimaron la masa grasa y la masa de músculo esquelético utilizando un análisis de impedancia bioeléctrica (BIA y métodos antropométricos con el fin de investigar si el uso de BIA o de la antropometría sería útil en tales condiciones de campo. La grasa corporal total estimada por BIA fue significativamente mayor en comparación con la antropometría (P < 0,001. Cuando se compararon los resultados entre BIA y antropometría, se encontraron niveles de concordancia bajos a moderados. Estos resultados concuerdan con las diferencias halladas con el análisis Bland-Altman, lo que indica que la ecuación antropométrica de Ball et al. posee el mayor grado de concordancia (desviación = -3,0 ± 5,8 kg con BIA, con Stewart et al. (desviación = -6,4 ± 6,3 kg, Faulkner (desviación = -4,7 ± 5,8 kg y Wilmore-Siri (desviación = -4,8 ± 6,2 kg. La estimación de la masa de músculo esquelético fue significativamente superior con BIAS que con antropometría (P < 0,001. Los resultados de la ICC y del método Bland-Altman muestran que la ecuación antropométrica de Lee et al. (desviación = -5,4 ± 5,3 kg produjo el mayor grado de concordancia. El método combinado de Janssen et al. entre antropometría y BIA mostró el menor grado de concordancia (desviación = -12,5 ± 5,7 kg. Hubo una diferencia estadísticamente significativa entre los resultados

  16. Comparison of body fat in Brazilian adult females by bioelectrical impedance analysis

    Science.gov (United States)

    Altamir, Vaz; Frère, Slaets Annie France; Ramírez Leonardo, López

    2012-12-01

    Body-fat is essential for human body, provided that its amount is at healthy levels. If in-excess body-fat is deleterious, its lack is otherwise also harmful. Estimated percent body-fat performed with commercially available devices measuring bioimpedance have many advantages, such as easy measurement and low cost. However, these measurements are based on standard models and equations that are not disclosed by manufacturers, and this leads to questioning the validity of these estimates for Brazilian females. The aim of this study was to compare electrical tetrapolar and octapolar impedance results obtained with commercially available equipment: Maltron BF-906 and OMRON 510-W. Data analysis involved descriptive and inferential statistics. Devices used in this study to estimate body fat quantity have not shown any significant differences in results; this is a major issue when selecting equipment based on three factors: study focus, available financial resources, and target population. Results obtained from the two devices have not shown any significant differences, which lead to the conclusion that either device may be reliably used.

  17. Foot-to-foot bioelectrical impedance accurately tracks direction of adiposity change in overweight and obese 7- to 13-year-old children.

    Science.gov (United States)

    Kasvis, Popi; Cohen, Tamara R; Loiselle, Sarah-Ève; Kim, Nicolas; Hazell, Tom J; Vanstone, Catherine A; Rodd, Celia; Plourde, Hugues; Weiler, Hope A

    2015-03-01

    Body composition measurements are valuable when evaluating pediatric obesity interventions. We hypothesized that foot-to-foot bioelectrical impedance analysis (BIA) will accurately track the direction of adiposity change, but not magnitude, in part due to differences in fat patterning. The purposes of this study were to examine the accuracy of body composition measurements of overweight and obese children over time using dual-energy x-ray absorptiometry (DXA) and BIA and to determine if BIA accuracy was affected by fat patterning. Eighty-nine overweight or obese children (48 girls, 41 boys, age 7-13 years) participating in a randomized controlled trial providing a family-centered, lifestyle intervention, underwent DXA and BIA measurements every 3 months. Bland-Altman plots showed a poor level of agreement between devices for baseline percent body fat (%BF; mean, 0.398%; +2SD, 8.685%; -2SD, -7.889%). There was overall agreement between DXA and BIA in the direction of change over time for %BF (difference between visits 3 and 1: DXA -0.8 ± 0.5%, BIA -0.7 ± 0.5%; P = 1.000) and fat mass (FM; difference between visits 3 and 1: DXA 0.7 ± 0.5 kg, BIA 0.6 ± 0.5 kg; P = 1.000). Bioelectrical impedance analysis measurements of %BF and FM at baseline were significantly different in those with android and gynoid fat (%BF: 35.9% ± 1.4%, 32.2% ± 1.4%, P < .003; FM: 20.1 ± 0.8 kg, 18.4 ± 0.8, P < .013). Bioelectrical impedance analysis accurately reports the direction of change in FM and FFM in overweight and obese children; inaccuracy in the magnitude of BIA measurements may be a result of fat patterning differences.

  18. Impedance-estimation methods, modeling methods, articles of manufacture, impedance-modeling devices, and estimated-impedance monitoring systems

    Science.gov (United States)

    Richardson, John G.

    2009-11-17

    An impedance estimation method includes measuring three or more impedances of an object having a periphery using three or more probes coupled to the periphery. The three or more impedance measurements are made at a first frequency. Three or more additional impedance measurements of the object are made using the three or more probes. The three or more additional impedance measurements are made at a second frequency different from the first frequency. An impedance of the object at a point within the periphery is estimated based on the impedance measurements and the additional impedance measurements.

  19. Developing and Validating an Age-Independent Equation Using Multi-Frequency Bioelectrical Impedance Analysis for Estimation of Appendicular Skeletal Muscle Mass and Establishing a Cutoff for Sarcopenia.

    Science.gov (United States)

    Yamada, Yosuke; Nishizawa, Miyuki; Uchiyama, Tomoka; Kasahara, Yasuhiro; Shindo, Mikio; Miyachi, Motohiko; Tanaka, Shigeho

    2017-07-19

    Background: Appendicular skeletal muscle (or lean) mass (ALM) estimated using dual-energy X-ray absorptiometry (DXA) is considered to be a preferred method for sarcopenia studies. However, DXA is expensive, has limited portability, and requires radiation exposure. Bioelectrical impedance analysis (BIA) is inexpensive, easy to use, and portable; thus BIA might be useful in sarcopenia investigations. However, a large variety of models have been commercially supplied by different companies, and for most consumer products, the equations estimating ALM are not disclosed. It is therefore difficult to use these equations for research purposes. In particular, the BIA equation is often age-dependent, which leads to fundamental difficulty in examining age-related ALM loss. The aims of the current study were as follows: (1) to develop and validate an equation to estimate ALM using multi-frequency BIA (MF-BIA) based on theoretical models, and (2) to establish sarcopenia cutoff values using the equation for the Japanese population. Methods: We measured height (Ht), weight, and ALM obtained using DXA and a standing-posture 8-electrode MF-BIA (5, 50, 250 kHz) in 756 Japanese individuals aged 18 to 86-years-old (222 men and 301 women as developing equation group and 97 men and 136 women as a cross validation group). The traditional impedance index (Ht²/Z50) and impedance ratio of high and low frequency (Z250/Z₅) of hand to foot values were calculated. Multiple regression analyses were conducted with ALM as dependent variable in men and women separately. Results: We created the following equations: ALM = (0.6947 × (Ht²/Z50)) + (-55.24 × (Z250/Z₅)) + (-10,940 × (1/Z50)) + 51.33 for men, and ALM = (0.6144 × (Ht²/Z50)) + (-36.61 × (Z250/Z₅)) + (-9332 × (1/Z50)) + 37.91 for women. Additionally, we conducted measurements in 1624 men and 1368 women aged 18 to 40 years to establish sarcopenia cutoff values in the Japanese population. The mean values minus 2 standard

  20. Evaluation of the BOD POD and leg-to-leg bioelectrical impedance analysis for estimating percent body fat in National Collegiate Athletic Association Division III collegiate wrestlers.

    Science.gov (United States)

    Dixon, Curt B; Deitrick, Ronald W; Pierce, Joseph R; Cutrufello, Paul T; Drapeau, Linda L

    2005-02-01

    The purpose of this study was to compare percent body fat (%BF) estimated by air displacement plethysmography (ADP) and leg-to-leg bioelectrical impedance analysis (LBIA) with hydrostatic weighing (HW) in a group (n = 25) of NCAA Division III collegiate wrestlers. Body composition was assessed during the preseason wrestling weight certification program (WCP) using the NCAA approved methods (HW, 3-site skinfold [SF], and ADP) and LBIA, which is currently an unaccepted method of assessment. A urine specific gravity less than 1.020, measured by refractometry, was required before all testing. Each subject had all of the assessments performed on the same day. LBIA measurements (Athletic mode) were determined using a Tanita body fat analyzer (model TBF-300A). Hydrostatic weighing, corrected for residual lung volume, was used as the criterion measurement. The %BF data (mean +/- SD) were LBIA (12.3 +/- 4.6), ADP (13.8 +/- 6.3), SF (14.2 +/- 5.3), and HW (14.5 +/- 6.0). %BF estimated by LBIA was significantly (p < 0.01) smaller than HW and SF. There were no significant differences in body density or %BF estimated by ADP, SF, and HW. All methods showed significant correlations (r = 0.80-0.96; p < 0.01) with HW. The standard errors of estimate (SEE) for %BF were 1.68, 1.87, and 3.60%; pure errors (PE) were 1.88, 1.94, and 4.16% (ADP, SF, and LBIA, respectively). Bland-Atman plots for %BF demonstrated no systematic bias for ADP, SF, and LBIA when compared with HW. These preliminary findings support the use of ADP and SF for estimating %BF during the NCAA WCP in Division III wrestlers. LBIA, which consistently underestimated %BF, is not supported by these data as a valid assessment method for this athletic group.

  1. Use of bioelectrical impedance analysis to assess body composition in rural Gambian children

    NARCIS (Netherlands)

    Prins, M.; Hawkesworth, S.; Wright, A.; Fulford, A.J.C.; Jarjou, L.M.A.; Prentice, A.M.; Moore, S.E.

    2008-01-01

    Objective: To validate the Tanita BC-418MA Segmental Body Composition Analyser and four-site skinfold measurements for the prediction of total body water (TBW), percentage fat-free mass (% FFM) and percentage body fat (%BF) in a population of rural Gambian children. Subjects/Methods: One hundred and

  2. [Variability in bioelectrical impedance assessment of body composition depending on measurement conditions: influence of fast and rest].

    Science.gov (United States)

    Cáceres, Diana Isabel; Sartor-Messagi, Monique; Rodríguez, Diego Agustín; Escalada, Ferran; Gea, Joaquim; Orozco-Levi, Mauricio; Marco, Ester

    2014-12-01

    Bioelectrical Impedance Assessment (BIA) is one of the main tools to measure body composition. BIA is recommended in fasting and after 60 minutes of rest; however, this cannot always be guaranteed in healthcare practice. To establish the reliability of the body composition parameters assessed with BIA under different physiological conditions: fast + rest, fast + no-rest and no-fast + no-rest in healthy volunteers. Transversal study including 25 healthy volunteers aged 18-34 (12 men, 13 women). A BIA was performed under three different conditions: 1) fast + 60 minute rest in cubito supino (gold standard), 2) fast + no rest and 3) no fast + no rest. The collected parameters were: lean mass and fat mass (Kg) and body water (in liters and as body weight percentage). The intraclass correlation coefficient (ICC) was applied for the assessment of concordance within the different measurements. Compared to the gold standard, the difference in lean mass means in the condition of fast + no-rest, was -0.15 (DE 1.44) in men and 0.98 (DE 1.36) in women; fat mass decreased in 0.06 (DE 1.55) in men and 0.82 (DE 1.5) in women; ICC ranged between 0.826-0.995 in all comparisons. In the condition of no-fast + no rest, lean mass decreased an average of 0.05 (DE 0.33) in men and it increased 0.62 (DE 0.46) in women; fat mass decreased 0.57 (DE 0.82) in men and 0.46 (DE 0.60) in women; ad ICC ranged between 0.942 and 0.999, except in body water in men, where it was 0.340. Although relevant, the differences observed in parameters from BIA when comparing the gold standard condition (fast + rest) with the other conditions (fast + no-rest and no-fast + no-rest) are of little magnitude. In clinical practice, the assessment of body composition allows to take decisions when planning treatment for patients with a poor physical condition. The reliability of the parameters acquired via BIA within different physiological conditions of fast and rest is excellent (CCI >0.75) in healthy adults aged 19

  3. Hand-to-Hand Model for Bioelectrical Impedance Analysis to Estimate Fat Free Mass in a Healthy Population

    Directory of Open Access Journals (Sweden)

    Hsueh-Kuan Lu

    2016-10-01

    Full Text Available This study aimed to establish a hand-to-hand (HH model for bioelectrical impedance analysis (BIA fat free mass (FFM estimation by comparing with a standing position hand-to-foot (HF BIA model and dual energy X-ray absorptiometry (DXA; we also verified the reliability of the newly developed model. A total of 704 healthy Chinese individuals (403 men and 301 women participated. FFM (FFMDXA reference variables were measured using DXA and segmental BIA. Further, regression analysis, Bland–Altman plots, and cross-validation (2/3 participants as the modeling group, 1/3 as the validation group; three turns were repeated for validation grouping were conducted to compare tests of agreement with FFMDXA reference variables. In male participants, the hand-to-hand BIA model estimation equation was calculated as follows: FFMmHH = 0.537 h2/ZHH − 0.126 year + 0.217 weight + 18.235 (r2 = 0.919, standard estimate of error (SEE = 2.164 kg, n = 269. The mean validated correlation coefficients and limits of agreement (LOAs of the Bland–Altman analysis of the calculated values for FFMmHH and FFMDXA were 0.958 and −4.369–4.343 kg, respectively, for hand-to-foot BIA model measurements for men; the FFM (FFMmHF and FFMDXA were 0.958 and −4.356–4.375 kg, respectively. The hand-to-hand BIA model estimating equation for female participants was FFMFHH = 0.615 h2/ZHH − 0.144 year + 0.132 weight + 16.507 (r2 = 0.870, SEE = 1.884 kg, n = 201; the three mean validated correlation coefficient and LOA for the hand-to-foot BIA model measurements for female participants (FFMFHH and FFMDXA were 0.929 and −3.880–3.886 kg, respectively. The FFMHF and FFMDXA were 0.942 and −3.511–3.489 kg, respectively. The results of both hand-to-hand and hand-to-foot BIA models demonstrated similar reliability, and the hand-to-hand BIA models are practical for assessing FFM.

  4. Application of body mass index adjusted for fat mass (BMIfat obtained by bioelectrical impedance in adults

    Directory of Open Access Journals (Sweden)

    Mírele Savegnago Mialich

    2014-08-01

    Full Text Available Introduction: Body mass index (BMI has been one of the methods most frequently used for diagnose obesity, but it isn't consider body composition. Objective: This study intends to apply one new adiposity index, the BMI adjusted for fat mass (BMIfat developed by Mialich, et al. (2011, in a adult Brazilian sample. Methods: A cross-sectional study with 501 individuals of both genders (366 women, 135 men aged 17 to 38 years and mean age was 20.4 ± 2.8 years, mean weight 63.0 ± 13.5 kg, mean height 166.9 ± 9.0 cm, and BMI 22.4 ± 3.4 kg/m². Results and discussion: High and satisfactory R2 values were obtained, i.e., 91.1%, 91.9% and 88.8% for the sample as a whole and for men and women, respectively. Considering this BMIfat were developed new ranges, as follows: 1.35 to 1.65 (nutritional risk for malnutrition, > 1.65 and ≤ 2.0 (normal weight and > 2.0 (obesity. The BMIfat had a more accurate capacity of detecting obese individuals (0.980. 0.993, 0.974 considering the sample as a whole and women and men, respectively, compared to the traditional BMI (0.932, 0.956, 0.95. Were also defined new cut-off points for the traditional BMI for the classification of obesity, i.e.: 25.24 kg/m² and 28.38 kg/m² for men and women, respectively. Conclusion: The BMIfat was applied for the present population and can be adopted in clinical practice. Further studies are needed to determine its application to different ethnic groups and to compare this index to others previously described in the scientific literature.

  5. Bioelectrical impedance analysis (BIA) equations validation against hydrodensitometry in a Colombian population

    Science.gov (United States)

    Caicedo-Eraso, J. C.; Gonzalez-Correa, C. A.; Gonzalez-Correa, C. H.

    2013-04-01

    Several studies have shown that the accuracy of BIA results depends of ethnicity, age, gender, hormonal and genetic variations and, so far, there are not specific equations for Colombian population. The purpose was to evaluate reported BIA equations to determine their usefulness in body composition assessment in young females from Colombia using hydrodensitometry as the reference method. A sample of 30 young females was evaluated. Inclusion and exclusion criteria were defined to minimize the variability of BIA. Height, weight, multi-frequency BIA, residual lung volume (RV) and underwater weight (UWW) were measured. Five BIA equations met the inclusion criteria of this study. Three equations overestimated and two equations underestimated body fat (BF). Paired Student t-test and Bland and Altman analysis (p<0.05) showed significant differences in four BIA equations. However, all standard error of estimate (SEE) to BF was greater than 2.7 kg. This study showed that the five selected BIA equations are not valid for estimation of body composition in young females from Colombia. It is recommended to develop BIA equations to improve BF fat assessment in our population.

  6. Pengembangan Bioelectrical Impedance Sebagai Control Commands Pengaturan Kecepatan Gerak Kursi Roda Dengan Metoda PID Controller

    Directory of Open Access Journals (Sweden)

    Juli Sardi

    2014-09-01

    Full Text Available In the present study, bioimpedance signals of human body was utilized to control speed of a wheelchair movement. A bioimpedance is electrically passive part contained the body tissues. The research is one of alternative solutions for patients with paralysis of the upper and lower limb. Firstly, design of system of the research consisted of bioimpedance measuring instruments and a mechanical design of the wheelchair. Bioimpedance measurement was performed by injecting a sinusoidal current source of 0.5 mArms with a frequency of 50 kHz to muscle tissue (shoulder to obtain the output voltage in the range of 0-5 Vdc. With impulse and manual thresholding methods, the voltage signal was classified into several controls command to adjust the speed and direction of the wheelchair control based on PID Controller. The experimental result of the research was realization of bioimpedance signal that used as a reference to control the direction and speed of the wheelchair with a success rate of 86.7 %. A wheelchair velocity was classified into three types of motion, namely slow, medium and fast. Slow speed has a rated speed of 30 Cm/s, medium speed value speed of 40 Cm/s and fast speed value of 50 Cm/s. The wheelchair can also turn to the left and the right in accordance with the wishes of wheelchair user beside to moving forward.

  7. Serial measurements of body composition in obese subjects during a very-low-energy diet (VLED) comparing bioelectrical impedance with hydrodensitometry.

    Science.gov (United States)

    Carella, M J; Rodgers, C D; Anderson, D; Gossain, V V

    1997-05-01

    Bioelectrical impedance analysis (BIA) is a convenient, inexpensive, and noninvasive technique for measuring body composition. BIA has been strongly correlated with total body water (TBW) and also has been validated against hydrodensitometry (HD). The accuracy and clinical utility of BIA and HD during periods of substantial weight loss remain controversial. We measured body composition in moderately and severely obese patients serially using both methods during a very-low-energy diet (VLED). Mean initial weight in these patients was 116 (+/-30) kg (range, 74-196 kg). Mean weight loss was 24 (+/-13) kg with a decrease in fat mass (FM) by HD of kg (p < 0.001) and a decrease in fat-free mass (FFM) of 3.6 kg (p < 0.05). Loss of FFM is best predicted by the rate (kg/wk) of weight loss (r2 = 0.86, p < 0.0001). FFM, as predicted from BIA equations, was highly correlated with FFM as estimated by HD during all testing sessions (r = 0.92-0.98). Although highly correlated, BIA overestimated FFM relative to HD and this difference appeared to be more pronounced for taller patients with greater truncal obesity. Although the discrepancy was no greater during weight-loss treatment, the level of disagreement was considerable. Therefore, the two methods cannot be used interchangeably to monitor relative changes in body composition in patients with obesity during treatment with VLED. The discrepancy between BIA and HD may be caused by body mass distribution considerations and by perturbations in TBW which affect the hydration quotient for FFM (BIA) and/or which affect the density constants for FFM and FM (HD).

  8. Bioelectrical impedance phase angle in clinical practice: implications for prognosis in stage IIIB and IV non-small cell lung cancer

    Directory of Open Access Journals (Sweden)

    Grutsch James F

    2009-01-01

    Full Text Available Abstract Background A frequent manifestation of advanced lung cancer is malnutrition, timely identification and treatment of which can lead to improved patient outcomes. Bioelectrical impedance analysis (BIA is an easy-to-use and non-invasive technique to evaluate changes in body composition and nutritional status. We investigated the prognostic role of BIA-derived phase angle in advanced non-small cell lung cancer (NSCLC. Methods A case series of 165 stages IIIB and IV NSCLC patients treated at our center. The Kaplan Meier method was used to calculate survival. Cox proportional hazard models were constructed to evaluate the prognostic effect of phase angle, independent of stage at diagnosis and prior treatment history. Results 93 were males and 72 females. 61 had stage IIIB disease at diagnosis while 104 had stage IV. The median phase angle was 5.3 degrees (range = 2.9 – 8. Patients with phase angle 5.3 had 12.4 months (95% CI: 10.5 to 18.7; n = 84; (p = 0.02. After adjusting for age, stage at diagnosis and prior treatment history we found that every one degree increase in phase angle was associated with a relative risk of 0.79 (95% CI: 0.64 to 0.97, P = 0.02. Conclusion We found BIA-derived phase angle to be an independent prognostic indicator in patients with stage IIIB and IV NSCLC. Nutritional interventions targeted at improving phase angle could potentially lead to an improved survival in patients with advanced NSCLC.

  9. Bioelectrical impedance vectorial analysis and nutritional status of older women according. 10.5007/1980-0037.2011v13n6p415

    Directory of Open Access Journals (Sweden)

    Sandra Maria Lima Ribeiro

    2011-11-01

    Full Text Available The objective of the present study was to compare and discuss the nutritional status of older women according to different categories of BMI. Additionally, the study was aimed at introducing the bioelectrical impedance vector analysis (BIVA as a tool to assess the nutritional status. Thirty-two women (60 years or older, physically independent, and with moderate level of physical activity were divided into three groups according toBMI classification: G1 (BMI28 Kg/ m2. The following variables were analyzed as indicators of nutritional status: body mass and height to calculate BMI, waist circumference (WC, hip circumference (HC, waisthipratio (WHR, bioelectrical impedance (BIVA, resting energy expenditure (REE, biochemical markers of nutritional status (glucose, total cholesterol, and fractions, IGF-1, and leptin. The groups were compared using ANOVA and the Hotelling’s T 2 test for vector analysis. The main findings based on vector displacement showed lower reactance and higher resistance in G1. G3 showed the highest values of CC and leptin, and also lower REE. Therefore, higher BMI suggested at the same time higher cell mass and higher risk of developing chronic diseases. In turn, lower BMI values suggested reduced fat-free body mass. These results confirm the search for specific classification of BMI for the elderly and suggest the BIVA as a viable alternative in physical and nutritional assessment.

  10. Measurement of body composition changes during weight loss in obese men using multi-frequency bioelectrical impedance analysis and multi-compartment models.

    Science.gov (United States)

    Johnstone, Alexandra M; Faber, Peter; Gibney, Eileen R; Lobley, Gerald E; Stubbs, R James; Siervo, Mario

    2014-01-01

    The accurate measurement of changes in body composition is important to assess the contribution of fat and fat free mass to total body mass change as a measure of the effectiveness of weight loss programmes. Bioelectrical impedance spectroscopy (BIS) is a rapid and non-invasive technique which could be applied to assess body composition changes. The aim of the study was to evaluate the accuracy of the BIS for the measurement of fat mass (FM), total body water (TBW) and extracellular water (ECW) changes induced by different degrees of caloric deficit in obese men. Three groups of six, obese men participated in either (i) a total fast (for 6 days); (ii) a VLCD (2.5 MJ/day for 3 weeks); or (iii) LCD (5.2 MJ/day for 6 weeks). FM was measured using a 4-compartment (4-C) model. TBW and ECW were determined by dilution methods, respectively. TBW, ECW and FM were also assessed with BIS. Body weight loss in the fasting group was 6.0 ± 1.3 kg over 6 days; the VLCD group lost 9.2 ± 1.2 kg over 21 days and the LCD group lost 12.6 ± 2.4 kg over 42 days. BIS underestimated FM changes (bias = -3.3 ± 3.8 kg) and overestimated changes in TBW and ECW by +1.8 ± 4.8 kg and +2.3 ± 6.4 kg, respectively. The measurement error was consistently larger in the fasting group and the magnitude of the bias interacted significantly with the rate of weight loss. Rapid weight loss affects the accuracy of the BIS in detecting changes in body composition. A careful interpretation of the results is needed when sizable changes in body water compartments occurs. © 2014 Asian Oceanian Association for the Study of Obesity . Published by Elsevier Ltd. All rights reserved.

  11. Comparison of bioelectrical impedance with skinfold thickness and X-ray absorptiometry to measure body composition in HIV-infected with lipodistrophy.

    Science.gov (United States)

    Siqueira Vassimon, H; Siqueira Vasimon, H; Jordao, A A; Albuquerque de Paula, F J; Artioli Machado, A; Pontes Monteiro, J

    2011-01-01

    Human immunodeficiency vírus (HIV)-associated lipodystrophy syndrome (LS) includes body composition and metabolic alterations. Lack of validated criteria and tools make difficult to evaluate body composition in this group. The aim of the study was to compare different methods to evaluate body composition between Brazilians HIV subjects with (HIV+LIPO+) or without LS (HIV+LIPO-) and healthy subjects (Control). in a cross-sectional analyses, body composition was measured by bioelectrical impedance analysis (BIA), skinfold thickness (SF) and dual-energy x-ray absorptiometry (DXA) in 10 subjects from HIV+LIPO+ group; 22 subjects from HIV+LIPO- group and 12 from Control group. There were no differences in age and body mass index (BMI) between groups. The fat mass (FM) (%) estimated by SF did not correlate with DXA in HIV+LIPO+ group (r = 0,46/ p > 0,05) and had fair agreement in both HIV groups (HIV+LIPO+ =0,35/ HIV+ LIPO- = 0,40). BIA had significant correlation in all groups (p < 0,05) and strong agreement, meanly in HIV groups, for FM (HIV+LIPO+ = 0,79/ HIV+LIPO- = 0,85 / Control = 0,60) and for fat free mass (FFM) (HIV+LIPO+ = 0,93 / HIV+LIPO- = 0,92 / Control = 0,73). Total fat mass can be measured by BIA with good precision, but not by SF in HIV-infected patients with LS. Segmental BIA, triciptal SF, circumferences of arms, waist and legs maybe alternatives that need more studies.

  12. A Comparison Study of Portable Foot-to-Foot Bioelectrical Impedance Scale to Measure Body Fat Percentage in Asian Adults and Children

    Directory of Open Access Journals (Sweden)

    Pei Ying Sim

    2014-01-01

    Full Text Available Objective. To compare the measurements of body fat percentage (BF% using the foot-to-foot bioelectrical impedance analysis (FTF-BIA with the direct segmental multifrequency BIA (DSM-BIA. Methods. There were 36 men and 52 women (37.1±14.3 years with 57% Malays, 30% Chinese, and 13% Indian. For children, there were 45 boys and 26 girls (11.5±2.5 years with 52% Malay, 15% Chinese, and 33% Indian. Results. Mean height for men was 168.4 cm, 11 cm taller than women. Men were 10 kg heavier than women at 70 kg. BF% in women was 32% and 33% whereas BF% in men was 23% and 25% when measured using FTF-BIA and DSM-BIA, respectively. In children, BF% measured with FTF-BIA and DSM-BIA was 49% and 46%, respectively. The correlations were significant for men (r=0.92, SEE = 2.80, women (r=0.91, SEE = 3.31, boys (r=0.95, SEE = 5.44, and girls (r=0.96, SEE = 5.27. The BF% in underweight/normal (r=0.92, SEE = 2.47 and that in overweight/obese adults (r=0.89, SEE = 3.61 were strongly correlated. The correlations were significant in normal/underweight (r=0.94, SEE = 3.78 and obese/overweight children (r=0.83, SEE = 6.49. All ethnic groups showed significant correlation with BF%. Malay adults (r=0.92, SEE = 3.27 and children (r=0.94, SEE = 0.88 showed significant mean differences in BF%. Conclusion. The FTF-BIA showed higher accuracy for all normal/underweight and Chinese group with acceptable overestimation in children and underestimation in adults. Caution should be taken when interpreting BF% depending on gender, BMI, and ethnicity.

  13. Assessment of body fat proportion by means of bioelectrical impedance in athletic boys aged 7 to 18 years with respect to specific types of instruments

    Directory of Open Access Journals (Sweden)

    Sigmund Martin

    2015-07-01

    Full Text Available BACKGROUND: Bioelectrical impedance (BIA seems an appropriate method for basic diagnostics of body composition in a practical environment. This is a non-time consuming non-invasive method that provides a high degree of response relevance. However, the values identifi ed by the BIA method are susceptible to a number of factors, which need to be taken into account during the investigation stage and interpretation of the results. One of the signifi cant factors infl uencing the outcomes of measurement is the instrument factor.OBJECTIVE: The objective of the present comparative survey was to analyse the proportions of body fat by means of the BIA hand-to-leg method and BIA leg-to-leg method in a sample of athletic individuals aged 7 to 18 years.METHODS: The survey included a total of 178 ice-hockey players aged 7 to 18 years. The proportion of body fat analysed by means of the BIA hand-to-leg method was measured by the Tanita BC-418 MA instrument. For the purposes of the BIA leg-to-leg method the Tanita BF-350 instrument was used (Tanita, Japan. Both instruments work at a frequency of 50 kHz.RESULTS: The percentage of body fat established by the BIA leg-to-leg method (M = 13.5%; SD = 4.8 indicated signifi cantly lower values of fat percentage than the values measured by the BIA hand-to-leg method (M = 17.1%; SD = 4.3. The overall diff erence represents an average value of 3.6% (standard mode; p < .001; d = 0.8. Regarding the monitored age categories the observed diff erences are in the range of 3.1–4.7% (p < .001; d = 0.7–1.2.CONCLUSION: The present study compares the proportions of body fat by means of the BIA leg-to-leg method and BIA hand-to-leg method in athletic boys aged 7 to 18 years. The results measured by the BIA leg-to-leg method signifi cantly undervalue the proportion of body fat in comparison with the BIA hand-to-leg method. The instrument factor and age factor represented signifi - cant variables infl uencing the results of the

  14. Calibration of bioelectrical impedance analysis for body composition assessment in Ethiopian infants using air-displacement plethysmography

    DEFF Research Database (Denmark)

    Christensen, Rasmus Wibæk; Kæstel, Pernille; Skov, R.

    2015-01-01

    on BIA in 0- to 6-month-old Ethiopian infants. SUBJECTS/METHODS: The study comprised a total of 186 BC assessments performed in 101 healthy infants, delivered at Jimma University Specialized Hospital. Infant air-displacement plethysmography (IADP) was the criterion method, whereas weight, length, sex...... by IADP, with an adjusted R(2) and root mean square error (RMSE) of 0.94 and 200 g, respectively. Adding impedance index to the model resulted in a significantly improved model fit (R(2)=0.95; RMSE=181 g). For infants below 3 months of age, inclusion of impedance index did not contribute to an improved...... model fit for predicting FFM compared with a model already comprising weight, sex and age. CONCLUSIONS: The derived equations predicted FFM with acceptable accuracy and may be used in future field surveys, epidemiological studies and clinical trials conducted in similar sub-Saharan African population...

  15. Bioelectric impedance overestimates the body fat in overweight and underestimates in Brazilian obese women: a comparation with Segal equation 1

    OpenAIRE

    Pimentel, G. D.; Bernhard, A. B. [UNESP; M. R. P. Frezza; Rinaldi, A. E. M. [UNESP; Roberto Carlos BURINI

    2010-01-01

    Introduction: Overweight and obesity are risk factors to appearance of cardiovascular diseases and anthropometry is important as clinical tool for planning and health policymaking at population level. Thus, aim of this work was to compare the simple body fat percentage (%BF) obtained straight by bioeletric impedance (BIA) to the one obtained by the equation of Segal et al (1988), which uses the BIA resistance value, overweight among adult women.Methods: This study conducted with 86 adult wome...

  16. Effectiveness of thigh-to-thigh current path for the measurement of abdominal fat in bioelectrical impedance analysis.

    Science.gov (United States)

    Hong, Ki Hwan; Lim, Yong Gyu; Park, Kwang Suk

    2009-12-01

    We present a new method measuring body impedance using a thigh-to-thigh current path, which can reflect the abdominal fat portion more sensitively and can be conveniently applied during the daily use on a toilet seat. Two pairs of electrodes were installed on a toilet seat to provide current and to permit voltage measurement through a thigh-to-thigh current path. The effectiveness of the method was compared with conventional foot-to-foot and hand-to-foot current paths by simulation and by experiments referenced to computed tomography (CT) image analysis. Body impedance using three different current paths was measured, and abdominal CT images were acquired for eight subjects. Measured body impedances were compared with the visceral to subcutaneous fat ratio (VF/SF) calculated from the CT-determined abdominal fat volume. The thigh-to-thigh current path was about 75% more sensitive in abdominal fat measurement than the conventional current paths in simulation experiments and displayed a higher VF/SF correlation (r = 0.768) than the foot-to-foot (r = 0.425) and hand-to-foot (r = 0.497) current paths.

  17. 基于FPGA的生物电阻抗成像系统设计%Design of bioelectrical electrical impedance tomography system based on FPGA

    Institute of Scientific and Technical Information of China (English)

    丁忠林; 陈晓艳; 吴佳妮

    2012-01-01

    According to requirements of electrical impedance tomography, the 16 electrode bioelectrical electrical impedance system was designed in this paper, which embedded 8 bits microprocessor PicoBlaze to realize logic control for generating excitation signals and high-speed A/D acquisition, realization of digital demodulation and the data was be transferred to PC through RS232, redraw the human body resistivity distribution or change images .The system provides a very good hardware design scheme for widely research of electrical impedance tomography.%根据电阻抗断层成像技术要求,设计了以Spartan3E系列XC3S500E FPGA为核心的16电极生物电阻抗成像系统,系统嵌入8 bit微处理器PicoBlaze实现逻辑控制并产生激励信号实现高速A/D采集及实现数字解调,通过RS232将采集数据传输到PC机,重建人体内部的电阻率分布或其变化图像.为广泛应用研究电阻抗断层成像技术提供一种硬件设计方案.

  18. Study of cystatin C (Cys C in relation to the calculation of the glomerular filtration rate and bioelectrical impedance analysis parameters in obese patients with and without type 2 diabetes

    Directory of Open Access Journals (Sweden)

    Mario Liani

    2012-01-01

    Full Text Available IntroductionAssessment of renal function based on quantification of the glomerular filtration rate (GFR is essential for early detection of damage and progression of renal diseases. The purpose of our study was to determine the value of cystatin C (Cys C assays in the calculation of the GFR and bioelectrical impedance analysis parameters in obese subjects aged 30-70 years with moderately damaged renal function.Materials and methodsCys C levels were measured with a new immunoturbidimetric kit (Roche Diagnostics and an automated Cobas c6000 analyzer. In the GFR calculation, creatinine and Cys C levels were included. The GFR calculated with the equation that included Cys C in obese and normal-weight patients is not affected by changes in the lean body mass.ResultsObese patients (N = 70 had a mean (± SD serum creatinine level of 1.52 ± 1.0 mg/dL and a mean Cys C level of 1.28 ± 0.59 mg/L. In this group, the GFR calculated on the basis of MDRD, Cys C, and creatinine clearance values showed similar filtered values between MDRD and Cys C and a DS value smaller in the case of Cys C. The correlation (R2 between GFR and its metabolite is higher in the case of Cys C when somatotype parameters (measured with bioelectrical impedance analysis were introduced into the equation.ConclusionsWhen Cys C is included in calculations of GFR, the result shows a higher correlation degree compared to the MDRD system. Given that Cys C shows less intra-individual variability than creatinine, it can be applied in routine diagnostics in a larger number of patients.

  19. New Regularization Method in Electrical Impedance Tomography

    Institute of Scientific and Technical Information of China (English)

    侯卫东; 莫玉龙

    2002-01-01

    Image reconstruction in elecrical impedance tomography(EIT)is a highly ill-posed inverse problem,Regularization techniques must be used in order to solve the problem,In this paper,a new regularization method based on the spatial filtering theory is proposed.The new regularized reconstruction for EIT is independent of the estimation of impedance distribution,so it can be implemented more easily than the maxiumum a posteriori(MAP) method.The regularization level in our proposed method varies spatially so as to be suited to the correlation character of the object's impedance distribution.We implemented our regularization method with two dimensional computer simulations.The experimental results indicate that the quality of the reconstructed impedance images with the descibed regularization method based on spatial filtering theory is better than that with Tikhonov method.

  20. Multi-frequency bioelectrical impedance: a comparison between the Cole-Cole modelling and Hanai equations with the classical impedance index approach.

    Science.gov (United States)

    Deurenberg, P; Andreoli, A; de Lorenzo, A

    1996-01-01

    Total body water and extracellular water were measured by deuterium oxide and bromide dilution respectively in 23 healthy males and 25 healthy females. In addition, total body impedance was measured at 17 frequencies, ranging from 1 kHz to 1350 kHz. Modelling programs were used to extrapolate impedance values to frequency zero (extracellular resistance) and frequency infinity (total body water resistance). Impedance indexes (height2/Zf) were computed at all 17 frequencies. The estimation errors of extracellular resistance and total body water resistance were 1% and 3%, respectively. Impedance and impedance index at low frequency were correlated with extracellular water, independent of the amount of total body water. Total body water showed the greatest correlation with impedance and impedance index at high frequencies. Extrapolated impedance values did not show a higher correlation compared to measured values. Prediction formulas from the literature applied to fixed frequencies showed the best mean and individual predictions for both extracellular water and total body water. It is concluded that, at least in healthy individuals with normal body water distribution, modelling impedance data has no advantage over impedance values measured at fixed frequencies, probably due to estimation errors in the modelled data.

  1. Wearable Multi-Frequency and Multi-Segment Bioelectrical Impedance Spectroscopy for Unobtrusively Tracking Body Fluid Shifts during Physical Activity in Real-Field Applications: A Preliminary Study

    Directory of Open Access Journals (Sweden)

    Federica Villa

    2016-05-01

    Full Text Available Bioelectrical Impedance Spectroscopy (BIS allows assessing the composition of body districts noninvasively and quickly, potentially providing important physiological/clinical information. However, neither portable commercial instruments nor more advanced wearable prototypes simultaneously satisfy the demanding needs of unobtrusively tracking body fluid shifts in different segments simultaneously, over a broad frequency range, for long periods and with high measurements rate. These needs are often required to evaluate exercise tests in sports or rehabilitation medicine, or to assess gravitational stresses in aerospace medicine. Therefore, the aim of this work is to present a new wearable prototype for monitoring multi-segment and multi-frequency BIS unobtrusively over long periods. Our prototype guarantees low weight, small size and low power consumption. An analog board with current-injecting and voltage-sensing electrodes across three body segments interfaces a digital board that generates square-wave current stimuli and computes impedance at 10 frequencies from 1 to 796 kHz. To evaluate the information derivable from our device, we monitored the BIS of three body segments in a volunteer before, during and after physical exercise and postural shift. We show that it can describe the dynamics of exercise-induced changes and the effect of a sit-to-stand maneuver in active and inactive muscular districts separately and simultaneously.

  2. Comparison of Wired and Wireless Bio-Electrical Impedance Fluid Status Monitoring Devices and Validation to Body Mass and Urine Specific Gravity Changes Following Mild Dehydration

    Science.gov (United States)

    2008-01-18

    status assessment method, ZOE2, is FDA approved for fluid status monitoring. The ZOE2 measures thoracic bio -electrical impedance. A new wireless version...impedance as a valid measure of hydration status in clinical or controlled settings. However, there is speculation as to the utility of bio -electrical...no significant differences were detected between pre- to post-practice for the ZOE2 or ZOEW device. Bio -electrical impedance, as measured by the ZOEW

  3. Body fat measurements in elite adolescent volleyball players: correlation between skinfold thickness, bioelectrical impedance analysis, air-displacement plethysmography, and body mass index percentiles.

    Science.gov (United States)

    Portal, Shawn; Rabinowitz, Jonathan; Adler-Portal, Dana; Burstein, Ruty Pilz; Lahav, Yair; Meckel, Yoav; Nemet, Dan; Eliakim, Alon

    2010-04-01

    Determination of body composition is an essential parameter in training athletes because low fat-muscle ratio might improve physical performance in many types of sports. Since training is often conducted in the field, it is important to determine whether simple field measurements of body composition assessment correlate with laboratory measurements. Examine the correlation of body fat content as measured using skinfold thicknesses (SF), air-displacement plethysmography (BOD POD), bioelectrical impedance analysis (BIA) and body mass index (BMI) age and gender adjusted percentiles. Body mass as measured by SF, BOD POD, BIA, and BMI percentiles were examined in 29 elite, national team level, male and female volleyball players (age range 13 to 18) at the beginning of the training season. Body fat percent measured by SF, BIA and BOD POD were highly positively correlated (r > 0.83). Measurements of body fat by SF, BIA and BOD POD were weakly correlated with BMI percentiles (r < 0.45). Results suggest that BMI percentile is not a good measure for body fat in adolescent elite male and female volleyball players. SF and measurements of body composition by BIA and BOD POD are essentially interchangeable.

  4. Prediction of fat-free mass and percentage of body fat in neonates using bioelectrical impedance analysis and anthropometric measures: validation against the PEA POD.

    Science.gov (United States)

    Lingwood, Barbara E; Storm van Leeuwen, Anne-Martine; Carberry, Angela E; Fitzgerald, Erin C; Callaway, Leonie K; Colditz, Paul B; Ward, Leigh C

    2012-05-01

    Accurate assessment of neonatal body composition is essential to studies investigating neonatal nutrition or developmental origins of obesity. Bioelectrical impedance analysis or bioimpedance analysis is inexpensive, non-invasive and portable, and is widely used in adults for the assessment of body composition. There are currently no prediction algorithms using bioimpedance analysis in neonates that have been directly validated against measurements of fat-free mass (FFM). The aim of the study was to evaluate the use of bioimpedance analysis for the estimation of FFM and percentage of body fat over the first 4 months of life in healthy infants born at term, and to compare these with estimations based on anthropometric measurements (weight and length) and with skinfolds. The present study was an observational study in seventy-seven infants. Body fat content of infants was assessed at birth, 6 weeks, 3 and 4·5 months of age by air displacement plethysmography, using the PEA POD body composition system. Bioimpedance analysis was performed at the same time and the data were used to develop and test prediction equations for FFM. The combination of weight+sex+length predicted FFM, with a bias of < 100 g and limits of agreement of 6-13 %. Before 3 months of age, bioimpedance analysis did not improve the prediction of FFM or body fat. At 3 and 4·5 months, the inclusion of impedance in prediction algorithms resulted in small improvements in prediction of FFM, reducing the bias to < 50 g and limits of agreement to < 9 %. Skinfold measurements performed poorly at all ages.

  5. 生物电阻抗技术研究进展%The Development of the Bioelectric Impedance Technologies

    Institute of Scientific and Technical Information of China (English)

    董秀珍

    2004-01-01

    本文从生物电阻抗血流图(bioimpedance rheohepatogram)、生物电阻抗测量(bioimpedance measurement)、生物组织阻抗频谱特性(bioimpedance spextroscopy)、生物电阻抗成像(electrical impedance imaging)等方面结合自己的研究工作,较全面地介绍并讨论了生物电阻抗技术的研究进展情况.

  6. Utilização da impedância bioelétrica na indicação do excesso de gordura visceral e subcutânea The use of bioelectrical impedance to detect excess visceral and subcutaneous fat

    Directory of Open Access Journals (Sweden)

    Rômulo A. Fernandes

    2007-12-01

    Full Text Available OBJETIVO: Analisar a relação e o desempenho da impedância bioelétrica na indicação do excesso de gordura visceral e sobrepeso/obesidade em jovens brasileiros. MÉTODOS: A amostra foi composta por 811 jovens de ambos os sexos (de 11 a 17 anos. A identificação do estado nutricional foi baseada no valor da dobra cutânea tricipital e gordura relativa (impedância bioelétrica e no excesso de gordura visceral no valor da circunferência de cintura. A análise estatística utilizou valores médios, desvios padrão, correlação linear, teste t de Student e curva ROC. RESULTADOS: Em ambos os gêneros, impedância bioelétrica apresentou bom desempenho na identificação do simultâneo excesso de gordura visceral e sobrepeso/obesidade, sendo mais específica (masculino = 92,4%; feminino = 93,8% do que sensível (masculino = 86,1%; feminino = 71,8%. CONCLUSÃO: Em conclusão, os achados oferecem suporte para o uso da impedância bioelétrica na identificação do excesso de gordura visceral e subcutânea em adolescentes.OBJECTIVE: To analyze bioelectrical impedance performance in detecting the presence of excess visceral fat and overweight/obesity in young Brazilians and how its values are related with them. METHODS: Study sample consisted of 811 adolescents of both genders (11 to 17 years of age. Nutritional status was determined based on triceps skinfold thickness (TSF, relative body fat (bioelectrical impedance, and excess visceral fat as determined by waist circumference. Statistical analysis was performed using means, standard deviations, linear correlation, Student's t test, and ROC curve. RESULTS: Bioelectrical impedance achieved good performance in identifying excess visceral fat associated with overweight/obesity in both genders, and was found to be more specific (male 92.4% and female 93.8% than sensitive (male 86.1% and female 71.8%. CONCLUSION: Our findings support the use of bioelectrical impedance to identify the presence of excess

  7. 多频多段人体生物电阻抗测量系统%A Bioelectrical Impedance Measurement System Based on Multi-Frequency and Multi-Segment Technology

    Institute of Scientific and Technical Information of China (English)

    高秀娥; 唐佳; 陈波

    2012-01-01

    Bioelectrical impedance is an important composition of human body, and reflects the physical conditions of human tissues to some extent. Based on this, a multi-frequency and multi-segment bioelectrical impedance measurement system is designed on the principle of eight electrodes. In fact, the system, which consists of MCU system, sinusoidal excitation current source, RMS-to-DC circuit and etc, has achieved the impedance measurement of the extremities as well as the trunk under the frequency ranged from 5 ~ 500 kHz. Experiment results show that the system finally realizes high-accuracy measurements of amplitude and phase of bioelectrical impedance with the result of a relative error of magnitude which is less than 0. 7% and an absolute error of phase which is less than 0.8°.%人体生物电阻抗是人体体成分的重要组成部分,在一定程度上反映了人体组织的生理状况.基于此,设计了一套基于八电极的多频多段人体生物电阻抗测量系统.测量系统由单片机系统、正弦交流激励电流源、有效值检测电路等组成,实现了5 ~ 500 kHz频率范围的左右上下肢及躯干的5段测量.测试结果表明,测量系统实现了人体生物电阻抗的幅值和相位的高精度测量,幅值相对误差小于0.7%,相位绝对误差小于0.8°.

  8. Assessing Body Fat of Children by Skinfold Thickness, Bioelectrical Impedance Analysis, and Dual-Energy X-Ray Absorptiometry: A Validation Study Among Malay Children Aged 7 to 11 Years.

    Science.gov (United States)

    Noradilah, Mohd Jonit; Ang, Yeow Nyin; Kamaruddin, Nor Azmi; Deurenberg, Paul; Ismail, Mohd Noor; Poh, Bee Koon

    2016-07-01

    This study aims to validate skinfold (SKF) and bioelectrical impedance analysis (BIA) against dual-energy X-ray absorptiometry (DXA) in determining body fat percentage (BF%) of Malay children aged 7 to 11 years. A total of 160 children had their BF% assessed using SKF and BIA, with DXA as the criterion method. Four SKF equations (SKFBray, SKFJohnston, SKFSlaughter, and SKFGoran) and 4 BIA equations (BIAManufacturer, BIAHoutkooper, BIARush, and BIAKushner) were used to estimate BF%. Mean age, weight, and height were 9.4 ± 1.1years, 30.5 ± 9.9 kg, and 131.3 ± 8.4 cm. All equations significantly underestimated BF% (P < .05). BIA equations had reasonable agreement with DXA and were independent of BF% with BIAManufacturer being the best equation. Although BIA underestimates BF% as compared with DXA, BIA was more suitable to measure BF% in a population that is similar to this study sample than SKF, suggesting a need to develop new SKF equations that are population specific. © 2016 APJPH.

  9. Method for conducting nonlinear electrochemical impedance spectroscopy

    Science.gov (United States)

    Adler, Stuart B.; Wilson, Jamie R.; Huff, Shawn L.; Schwartz, Daniel T.

    2015-06-02

    A method for conducting nonlinear electrochemical impedance spectroscopy. The method includes quantifying the nonlinear response of an electrochemical system by measuring higher-order current or voltage harmonics generated by moderate-amplitude sinusoidal current or voltage perturbations. The method involves acquisition of the response signal followed by time apodization and fast Fourier transformation of the data into the frequency domain, where the magnitude and phase of each harmonic signal can be readily quantified. The method can be implemented on a computer as a software program.

  10. Method for conducting nonlinear electrochemical impedance spectroscopy

    Energy Technology Data Exchange (ETDEWEB)

    Adler, Stuart B.; Wilson, Jamie R.; Huff, Shawn L.; Schwartz, Daniel T.

    2015-06-02

    A method for conducting nonlinear electrochemical impedance spectroscopy. The method includes quantifying the nonlinear response of an electrochemical system by measuring higher-order current or voltage harmonics generated by moderate-amplitude sinusoidal current or voltage perturbations. The method involves acquisition of the response signal followed by time apodization and fast Fourier transformation of the data into the frequency domain, where the magnitude and phase of each harmonic signal can be readily quantified. The method can be implemented on a computer as a software program.

  11. Percentage of body fat assessment using bioelectrical impedance analysis and dual-energy X-ray absorptiometry in a weight loss program for obese or overweight Chinese adults.

    Directory of Open Access Journals (Sweden)

    Yi-Chun Li

    Full Text Available The current study aimed to compare the estimates of body fat percentage (%BF by performing bioelectrical impedance analysis (BIA and dual energy X-ray absorptiometry (DXA in a sample of obese or overweight Chinese adults who participated in a weight-loss randomized control trial stratified by gender to determine whether or not BIA is a valid measurement tool. Among 189 adults [73 males, 116 females; age = 41 to 74 years; mean body mass index (BMI = 27.3 kg/m(2], assessments of %BF at the baseline and six months from the baseline were conducted by performing BIA and DXA. Bland-Altman analyses and multiple regression analyses were used to assess the relationships between %BFBIA and %BFDXA. Compared with DXA, BIA underestimated %BF [in males: 4.6, -2.4 to 11.7 (mean biases, 95% limit of agreement at the baseline, 1.4, -7.4 to 10.2 at the endpoint, and 3.2, -4.8 to 11.3 in changes; in females: 5.1, -2.4 to 12.7; 2.2, -6.1 to 10.4; and 3.0, -4.8 to 10.7, respectively]. For males and females, %BFDXA proved to be a significant predictor of the difference between DXA and BIA at the baseline, the endpoint, and in changes when BMI and age were considered (in males: p<0.01 and R (2 = 23.1%, 24.1%, 20.7%, respectively; for females: p<0.001 and R (2 = 40.4%, 48.8%, 25.4%, respectively. The current study suggests that BIA provides a relatively accurate prediction of %BF in individuals with normal weight, overweight, or obesity after the end of weight-loss program, but less accurate prediction of %BF in obese individuals at baseline or weight change during the weight-loss intervention program.

  12. EFFECT OF INTERMITTENT SUB-MAXIMAL EXERCISE ON PERCENT BODY FAT USING LEG-TO-LEG BIOELECTRICAL IMPEDANCE ANALYSIS IN CHILDREN

    Directory of Open Access Journals (Sweden)

    Joseph L. Andreacci

    2006-09-01

    Full Text Available The purpose of this investigation was to determine the effect of intermittent sub-maximal exercise on percent body fat (%BF estimated by leg-to-leg bioelectrical impedance analysis (LBIA in children. Fifty-nine children (29 girls; 30 boys mean age 9.0 ± 1.3 years participated in this study. LBIA measured %BF values were obtained immediately before and within five minutes after completing an intermittent exercise protocol consisting of three 8-minute sub-maximal exercise bouts (2.74 km·hr-1, 0% grade; 4.03 km·hr-1, 0% grade; and 5.47 km·hr-1, 0% grade each separated by a 5-min seated rest period. The three exercise bouts corresponded to 56%, 61% and 71% of maximal heart rate. Significant differences (p < 0.001 were observed for fat mass, fat free mass, total body water, and body weight, post-exercise in both groups. Significant reductions (p < 0.001 in %BF were observed post-exercise in the female (23.1 ± 9.9 vs. 21.8 ± 9. 9 % and male (23.3 ± 10.5 vs. 21.8 ± 10.2 % children when compared to pre-exercise values. However, for the majority of the subjects (females = 86%; males = 73% the decrease in %BF post- exercise was less than 2.0 %BF. These data indicate that sub-maximal intermittent exercise, that may be representative of daily free-form activities in children, will most likely have a limited impact on %BF estimates when the assessment is performed immediately post-exercise

  13. Body composition measurement: a review of hydrodensitometry, anthropometry, and impedance methods.

    Science.gov (United States)

    Brodie, D; Moscrip, V; Hutcheon, R

    1998-03-01

    Human body composition is an expression of genetic and nutritional factors. It can change as a consequence of exogenous influences such as training, disease, or diet and is therefore of particular interest to nutrition professionals. Two of the main methods of estimating body composition in this review (hydrodensitometry and anthropometry) have been in use for decades, but the third method (bioelectrical impedance) is more recent. The procedure, theoretical basis, assumptions, standard error of estimates, and comparisons with other techniques are presented for each of the three methods. References to general and specific populations are presented that illustrate regression equations for different ages, ethnic groups, and gender. The advantages and disadvantages of the three methods are reviewed with reference made to the alternative compartment models. Other methods (DEXA, infrared interactance) are briefly reviewed.

  14. Evaluation of bioelectrical impedance analysis (BIA) to measure condition and energy allocated to reproduction in marine fishes

    Science.gov (United States)

    Fitzhugh, G. R.; Wuenschel, M. J.; McBride, R. S.

    2010-04-01

    Reliable estimates of fish energy density at specific times prior to spawning may provide suitable proxies for egg production, and thereby help to explain some of the observed annual variation in recruits per spawner. Our goal is to develop and test modifications of BIA technology to measure energy allocation to reproduction for a variety of marine fishes. To date, a newly developed measuring board and probe system stabilized readings, which was demonstrated by a significant reduction in the coefficients of variation for impedance measures. Total body water, wet and dry weights could be predicted with very good precision (r2 = 0.92-0.99) using BIA measures of reactance or resistance for a number of finfish species. While constituent relationships (e.g. body water- body mass functions) did not differ seasonally, we did find that BIA measures are sensitive to body composition changes related to the seasonal spawning cycle. In an examination of monthly samples of tilefish, phase angle decreased below 15° in post-spawning (regressed) females. Such a monthly trend, which suggests available energy had decreased following the spawning season, was not evident from other, more traditional measures of condition including body-muscle water content, Fulton's K or ordinal measures of fat deposition (such as mesenteric fat). These preliminary results show that BIA technology is a promising application for tracking and efficiently predicting energetic condition of marine fishes.

  15. Application of bioelectrical impedance vector analysis (BIVA in dogs: a preliminary study on gender-related differences

    Directory of Open Access Journals (Sweden)

    Rebecca Ricci

    2010-01-01

    Full Text Available In this preliminary study, BIVA has been performed on 17 healthy Italian Hound dogs, 10 males (M and 7 females (F, in order to verify if gender-related differences can be detected. Only in F higher reactance (Xc values (F: 46.4 vs M: 37.7, P<0.05 and a significant negative correlation (-0.80, P<0.05 between BCS and resistance (R values were detected. 50%, 75% and 95% tolerance ellipses were calculated both in M and F using average Xc and R values standardized for withers height. Probably due to the low number of subjects used in the present study, the variability of the individual vector distribution (F: 79.6 vs M: 53.0Ohm/m, as well as the mean impedance vector lengtht (F: 548.2 vs M: 498.9Ohm/m, were similar in F and M. The gender-related difference in phase angle values was not significant (F: 0.168 vs M: 0.157, P=ns. In conclusion, the use of BIVA in dogs indicated differences between males and females which should be confirmed by a larger number of subjects.

  16. 生物电阻抗铜片电极的化学刻蚀工艺%Chemical etching process of copper electrode for bioelectrical impedance technology

    Institute of Scientific and Technical Information of China (English)

    周伟; 宋嵘; 蒋乐伦; 许文平; 梁国开; 程德才; 刘灵蛟

    2012-01-01

    为获得具有强稳定性能的生物电阻抗电极,采用化学刻蚀加工方法,制造出表面具有一系列微结构的金属铜片电极.通过改变加工工艺参数的方法,着重分析刻蚀时间、刻蚀温度、刻蚀液体浓度、样品尺寸等刻蚀工艺参数对铜片电极的蚀刻速率和表面微结构的影响.结果表明:刻蚀速率将随着刻蚀时间的延长而逐渐降低,随着刻蚀温度的升高而逐渐升高,而刻蚀样本尺寸对刻蚀速率的影响不大.选用合适的刻蚀液体浓度(组分3),在室温条件下刻蚀20 min,可以获得具有丰富表面微结构的铜片电极.另外,进行24 h电极对接的连续性交流阻抗测试,与心电电极相比,利用化学刻蚀加工的铜片电极,由于表面具有丰富的表面微结构,可以形成可靠的表面接触,从而具有稳定的交流阻抗值.%In order to obtain bioelectrical impedance electrodes with high stability,the chemical etching process was used to fabricate the copper electrode with a series of surface microstructures.By changing the etching processing parameters,some comparison experiments were performed to reveal the influence of etching time,etching temperature,etching liquid concentration,and sample sizes on the etching rate and surface microstructures of copper electrode.The result shows that the etching rate is decreased with increasing etching time,and is increased with increasing etching temperature.Moreover,it is found that the sample size has little influence on the etching rate.After choosing the reasonable etching liquid composition (formulation 3),the copper electrode with many surface microstructures can be obtained by chemical etching process at room temperature for 20 min.In addition,using the alternating current impedance test of electrode-electrode for 24 h,the copper electrode with a series of surface microstructures fabricated by the etching process presents a more stable impedance value compared with the

  17. Effect of intermittent sub-maximal exercise on percent body fat using leg-to-leg bioelectrical impedance analysis in children.

    Science.gov (United States)

    L Andreacci, Joseph; B Dixon, Curt; Ledezma, Christina; L Goss, Fredric

    2006-01-01

    The purpose of this investigation was to determine the effect of intermittent sub-maximal exercise on percent body fat (%BF) estimated by leg-to-leg bioelectrical impedance analysis (LBIA) in children. Fifty-nine children (29 girls; 30 boys) mean age 9.0 ± 1.3 years participated in this study. LBIA measured %BF values were obtained immediately before and within five minutes after completing an intermittent exercise protocol consisting of three 8-minute sub-maximal exercise bouts (2.74 km·hr(-1), 0% grade; 4.03 km·hr(-1), 0% grade; and 5.47 km·hr(-1), 0% grade) each separated by a 5-min seated rest period. The three exercise bouts corresponded to 56%, 61% and 71% of maximal heart rate. Significant differences (p < 0.001) were observed for fat mass, fat free mass, total body water, and body weight, post-exercise in both groups. Significant reductions (p < 0.001) in %BF were observed post-exercise in the female (23.1 ± 9.9 vs. 21.8 ± 9. 9 %) and male (23.3 ± 10.5 vs. 21.8 ± 10.2 %) children when compared to pre-exercise values. However, for the majority of the subjects (females = 86%; males = 73%) the decrease in %BF post- exercise was less than 2.0 %BF. These data indicate that sub-maximal intermittent exercise, that may be representative of daily free-form activities in children, will most likely have a limited impact on %BF estimates when the assessment is performed immediately post-exercise. Key PointsLBIA measures of body weight, percent body fat, fat mass, fat free mass and total body water were significantly lower after the intermittent sub-maximal exercise.The reductions in percent body fat for girls (1.4%) and boys (1.5%) compare favorably to previous investigations.Intermittent exercise, that may be representative of daily free-form activities in children, will most likely have a limited impact on LBIA percent body fat estimates.

  18. DXA, bioelectrical impedance, ultrasonography and biometry for the estimation of fat and lean mass in cats during weight loss

    Directory of Open Access Journals (Sweden)

    Borges Naida C

    2012-07-01

    Full Text Available Abstract Background Few equations have been developed in veterinary medicine compared to human medicine to predict body composition. The present study was done to evaluate the influence of weight loss on biometry (BIO, bioimpedance analysis (BIA and ultrasonography (US in cats, proposing equations to estimate fat (FM and lean (LM body mass, as compared to dual energy x-ray absorptiometry (DXA as the referenced method. For this were used 16 gonadectomized obese cats (8 males and 8 females in a weight loss program. DXA, BIO, BIA and US were performed in the obese state (T0; obese animals, after 10% of weight loss (T1 and after 20% of weight loss (T2. Stepwise regression was used to analyze the relationship between the dependent variables (FM, LM determined by DXA and the independent variables obtained by BIO, BIA and US. The better models chosen were evaluated by a simple regression analysis and means predicted vs. determined by DXA were compared to verify the accuracy of the equations. Results The independent variables determined by BIO, BIA and US that best correlated (p r2, 19 equations were selected (12 for FM, 7 for LM; however, only 7 equations accurately predicted FM and one LM of cats. Conclusions The equations with two variables are better to use because they are effective and will be an alternative method to estimate body composition in the clinical routine. For estimated lean mass the equations using body weight associated with biometrics measures can be proposed. For estimated fat mass the equations using body weight associated with bioimpedance analysis can be proposed.

  19. Interference of heart and transcutaneous oxygen monitoring in the measurement of bioelectrical impedance analysis in preterm newborns

    Directory of Open Access Journals (Sweden)

    Viviane C. Comym

    Full Text Available Abstract Objective: To verify if the connection of electrodes for heart and transcutaneous oxygen monitoring interfere with the measurement of electrical bioimpedance in preterm newborns. Methods: This was a prospective, blinded, controlled, cross-sectional, crossover study that assessed and compared paired measures of resistance (R and reactance (Xc by BIA, obtained with and without monitoring wires attached to the preterm newborn. The measurements were performed in immediate sequence, after randomization to the presence or absence of electrodes. The sample size calculated was 114 measurements or tests with monitoring wires and 114 without monitoring wires, considering for a difference between the averages of 0.1 ohms, with an alpha error of 10% and beta error of 20%, with significance <0.05. Results: No differences were observed between the R (677.37 ± 196.07 vs. 677.46 ± 194.86 and Xc (31.15 ± 9.36 vs. 31.01 ± 9.56 values obtained with and without monitoring wires, respectively, with good correlation between them (R: 0.997 and Xc: 0.968. Conclusion: The presence of heart and/or transcutaneous oxygen monitoring wires connected to the preterm newborn did not affect the values of R or Xc measured by BIA, allowing them to be carried out in this population without risks.

  20. Body fluid volumes measurements by impedance: A review of bioimpedance spectroscopy (BIS) and bioimpedance analysis (BIA) methods.

    Science.gov (United States)

    Jaffrin, Michel Y; Morel, Hélène

    2008-12-01

    This paper reviews various bioimpedance methods permitting to measure non-invasively, extracellular, intracellular and total body water (TBW) and compares BIA methods based on empirical equations of the wrist-ankle resistance or impedance at 50 kHz, height and weight with BIS methods which rely on an electrical model of tissues and resistances measured at zero and infinite frequencies. In order to compare these methods, impedance measurements were made with a multifrequency Xitron 4200 impedance meter on 57 healthy subjects which had undergone simultaneously a Dual X-ray absorptiometry examination (DXA), in order to estimate their TBW from their fat-free-mass. Extracellular (ECW) and TBW volumes were calculated for these subjects using the original BIS method and modifications of Matthie[Matthie JR. Second generation mixture theory equation for estimating intracellular water using bioimpedance spectroscopy. J Appl Physiol 2005;99:780-1], Jaffrin et al. [Jaffrin MY, Fenech M, Moreno MV, Kieffer R. Total body water measurement by a modification of the bioimpédance spectroscopy method. Med Bio Eng Comput 2006;44:873-82], Moissl et al. [Moissl UM, Wabel P, Chamney PW, Bosaeus I, Levin NW, et al. Body fluid volume determination via body composition spectroscopy in health and disease. Physiol Meas 2006;27:921-33] and their TBW resistivities were compared and discussed. ECW volumes were calculated by BIA methods of Sergi et al. [Sergi G, Bussolotto M, Perini P, Calliari I, et al. Accuracy of bioelectrical bioimpedance analysis for the assessment of extracellular space in healthy subjects and in fluid retention states. Ann Nutr Metab 1994;38(3):158-65] and Hannan et al. [Hannan WJ, Cowen SJ, Fearon KC, Plester CE, Falconer JS, Richardson RA. Evaluation of multi-frequency bio-impedance analysis for the assessment of extracellular and total body water in surgical patients. Clin Sci 1994;86:479-85] and TBW volumes by BIA methods of Kushner and Schoeller [Kushner RF

  1. Are ethnic and gender specific equations needed to derive fat free mass from bioelectrical impedance in children of South asian, black african-Caribbean and white European origin? Results of the assessment of body composition in children study.

    Directory of Open Access Journals (Sweden)

    Claire M Nightingale

    Full Text Available BACKGROUND: Bioelectrical impedance analysis (BIA is a potentially valuable method for assessing lean mass and body fat levels in children from different ethnic groups. We examined the need for ethnic- and gender-specific equations for estimating fat free mass (FFM from BIA in children from different ethnic groups and examined their effects on the assessment of ethnic differences in body fat. METHODS: Cross-sectional study of children aged 8-10 years in London Primary schools including 325 South Asians, 250 black African-Caribbeans and 289 white Europeans with measurements of height, weight and arm-leg impedance (Z; Bodystat 1500. Total body water was estimated from deuterium dilution and converted to FFM. Multilevel models were used to derive three types of equation {A: FFM = linear combination(height+weight+Z; B: FFM = linear combination(height(2/Z; C: FFM = linear combination(height(2/Z+weight}. RESULTS: Ethnicity and gender were important predictors of FFM and improved model fit in all equations. The models of best fit were ethnicity and gender specific versions of equation A, followed by equation C; these provided accurate assessments of ethnic differences in FFM and FM. In contrast, the use of generic equations led to underestimation of both the negative South Asian-white European FFM difference and the positive black African-Caribbean-white European FFM difference (by 0.53 kg and by 0.73 kg respectively for equation A. The use of generic equations underestimated the positive South Asian-white European difference in fat mass (FM and overestimated the positive black African-Caribbean-white European difference in FM (by 4.7% and 10.1% respectively for equation A. Consistent results were observed when the equations were applied to a large external data set. CONCLUSIONS: Ethnic- and gender-specific equations for predicting FFM from BIA provide better estimates of ethnic differences in FFM and FM in children, while generic equations

  2. Novel method for planar microstrip antenna matching impedance

    CERN Document Server

    Ali, Mahdi; Samet, Mounir

    2010-01-01

    Because all microstrip antennas have to be matched to the standard generator impedance or load, the input impedance matching method for antenna is particularly important. In this paper a new methodology in achieving matching impedance of a planar microstrip antenna for wireless application is described. The method is based on embedding an Interdigital capacitor. The fine results obtained by using a microstrip Interdigital capacitor for matching antenna impedance led to an efficient method to improve array antenna performance. In fact, a substantial saving on the whole surfaces as well as enhancement of the gain, the directivity and the power radiated was achieved.

  3. [Saarland Growth Study: analyses of body composition of children, aged 3 to 11 years. Measurement of height, weight, girth (abdomen, upper arm, calf) and skinfolds (triceps, biceps, subscapular,suprailiacal, abdominal) and bioelectric impedance (BIA)].

    Science.gov (United States)

    Weinand, C; Müller, S; Zabransky, S; Danker-Hopfe, H

    2000-01-01

    This study aimed to set up current reference charts of anthropometric data in the Saarland. Only national and international data were available to be compared but no former Saarland charts could be found. In the period between 1994 and 1995 we investigated children of 3 to 11 years in a cross-sectional study. Therefore we measured body height, weight, circumferences, skinfolds and bioelectrical impedance (BIA). No significant gender differences were found for body height and weight. Boys of all groups of age showed bigger abdominal circumferences than girls of the same age. On the other hand upper-arm and calf-girth of younger girls were larger than that from boys. In higher age groups circumferences become rather equal. The skinfolds of Saarland girls are thicker than those of boys. The urban rural comparison indicated no significant differences. Nor was any social divergence found among the aforementioned parameters. Regarding height Saarland children are seen to be similar or somewhat shorter than those examined in national or international studies. By the way, in higher percentiles the children in our study were heavier. Thus high BMI values of our study are bigger compared with former studies. According to the definition of obesity by the ECOG almost 20 to 30% of our children are obese. The older children become the higher is the percentage of obesity. Comparing girls and boys, bioelectrical impedance shows higher values for girls. In higher age classes resistance levels gets smaller, in boys more so than in girls. Body fat estimated by a formula based on BIA test parameters yielded negative values. So we propose the use of sex- and age-specific raw charts of BIA test parameters.

  4. Bioelectrical Impedance法による体組成の推定 : インピーダンス−体水分量(BI-TBW)法と皮下脂肪厚法から推定された日本人女性の%Fatの比較

    OpenAIRE

    小宮, 秀一; 今井, 克巳; 増田, 卓二; 赤崎, 房生

    1990-01-01

    This article reports a study in which the percent of fat estimated from bioelectrical impedance-total body water measurement and skinfold-body density method in Japanese women were compared. The bioelectrical impedance measurement provides a new approach to assessment of human body composition that is based on the principle that the electrical conductivity of lean body mass, which includes the protein matrix of adipose tissue, contains virtually all the water and conducting electrolytes in th...

  5. Association of nutrition parameters including bioelectrical impedance and systemic inflammatory response with quality of life and prognosis in patients with advanced non-small-cell lung cancer: a prospective study.

    Science.gov (United States)

    Sánchez-Lara, Karla; Turcott, Jenny G; Juárez, Eva; Guevara, Patricia; Núñez-Valencia, Carolina; Oñate-Ocaña, Luis F; Flores, Diana; Arrieta, Oscar

    2012-01-01

    Early identification and treatment of nutritional deficiencies can lead to improved outcomes in the quality of life (QoL) and survival of patients with nonsmall cell lung cancer (NSCLC). Noninvasive techniques are needed to evaluate changes in body composition as part of determining nutritional status. The aim of the study was to evaluate the association of nutritional parameters in health-related quality of life (HRQL) and survival in patients with advanced NSCLC. Chemotherapy-naïve patients with advanced NSCLC with good performance status Eastern Cooperative Oncology Group (ECOG) 0-2 were included prospectively in the study. We evaluated inflammatory parameters such as C-reactive protein, platelet/lymphocyte index, neutrophil/lymphocyte index, serum interleukin (IL)-6, and tumor necrosis factor-α, and nutritional variables such as body mass index (BMI) and serum albumin levels. Bioelectrical impedance analysis including phase angle was obtained before cisplatin-based chemotherapy was started. HRQL was assessed by application of the European Organization for Research and Treatment of Cancer Quality of Life Questionnaire (QLQ)-C30 and QLQ-LC13 instruments at baseline. Overall survival (OS) was calculated with the Kaplan-Meier method and analyzed with log-rank and Cox proportional hazard models. One hundred nineteen patients were included. Mean BMI was 24.8 ± 4.5 kg/m(2), average weight loss of patients was 8.4%, and median phase angle was 5.8°. Malnutrition measured by subjective global assessment (SGA), weight loss >10%, BMI >20 was associated with lower HRQL scales. Patients with ECOG 2, high content serum IL-6, lower phase angle, and malnutrition parameters showed lower OS; however, after multivariate analysis, only ECOG 2 [Hazard ratio (HR), 2.7; 95% confidence interval (95% CI), 1.5-4.7; P = 0.001], phase angle ≤5.8° (HR = 3.02; 95% CI: 1.2-7.11; P = 0.011), and SGA (HR = 2.7; 95% CI, 1.31-5.5; P = 0.005) were associated with poor survival. Patients

  6. A self-consistent impedance method for electromagnetic surface impedance modeling

    Science.gov (United States)

    Thiel, David V.; Mittra, Raj

    2001-01-01

    A two-dimensional, self-consistent impedance method has been derived and used to calculate the electromagnetic surface impedance above buried objects at very low frequencies. The earth half space is discretized using an array of impedance elements. Inhomogeneities in the complex permittivity of the earth are reflected in variations in these impedance elements. The magnetic field is calculated for each cell in the solution space using a difference equation derived from Faraday's and Ampere's laws. It is necessary to include an air layer above the earth's surface to allow the scattered magnetic field to be calculated at the surface. The source field is applied above the earth's surface as a Dirichlet boundary condition, whereas the Neumann condition is employed at all other boundaries in the solution space. This, in turn, enables users to use both finite and infinite magnetic field sources as excitations. The technique is shown to be computationally efficient and yields reasonably accurate results when applied to a number of one- and two-dimensional earth structures with a known surface impedance distribution.

  7. 应用生物电阻抗预测方程评价维持性血液透析患者干体质量%Assessment of dry weight among maintenance hemodialysis patients with the application of bioelectrical impedance prediction equation

    Institute of Scientific and Technical Information of China (English)

    杜静; 隋小妮; 赵战云; 邹作君

    2012-01-01

    Object To explore the accuracy of bioelectrical impedance prediction equation in the evaluation of dry weight among maintenance hemodialysis (MHD) patients. Methods Dry weight of 60 MHD patients was estimated using electrical impedance value of 50 KHz frequency measured by bioelectrical impedance analyzer, combined with slope method and new 3-compartment model. Dry weight of these participants was the post-dialysis weight, measured by inferior vena cava diameter (IVCD) method which was deemed as golden standard. Another 90 individuals with matched gender, age, height, body weight and BMI were selected to construct coefficient and compare the human body parameters with MHD patient. Results Pearson correlation coefficient between the evaluated dry weight by slope method and true dry weight was 0.991. Bland-Altman plot showed these two approaches bore poor consistency and the difference between them was far from zero. Pearson correlation coefficient between assessed dry weight by new 3-compartmental model and true dry weight was 0.993. Bland- Airman plot revealed good consistency between the two methods with stable and minor diffidence as their differences fluctuated near zero. Conclusion Different bioelectrical impedance measuring instrument gives rise to the impact on measured data. In this study, the new 3-compartment model predicts the dry weight of MHD patients more accurately.%目的 探讨运用生物电阻抗预测方程评价维持性血液透析(maintenance hemodialysis,MHD)患者干体质量的准确性. 方法 使用多频生物电阻抗分析仪测定60例MHD患者50千赫下电阻抗值,结合斜率法、新三室模型预测MHD患者干体质量.经下腔静脉直径(inferior vena cava diameter,IVCD)等综合评价,认为患者的干体质量即入选患者本次透析后体质量,可用于干体质量准确性评价.另选择性别、年龄、身高,体质量和体质量指数(BMI)相匹配个体87例,用于构建方程系数及与MHD患

  8. Estimativa da massa muscular esquelética em mulheres idosas: validade da impedância bioelétrica Validity of bioelectrical impedance analysis for the estimation of skeletal muscle mass in elderly women

    Directory of Open Access Journals (Sweden)

    Cassiano Ricardo Rech

    2010-04-01

    Full Text Available O presente estudo tem como objetivos: a verificar a concordância entre os métodos da impedância bioelétrica (BIA e da absortometria radiológica de dupla energia (DXA para a estimativa da massa muscular esquelética (MME; e b analisar o poder preditivo de variáveis antropométricas e da BIA para a predição da MME em idosas. Foram avaliadas 120 mulheres (60 a 81 anos, residentes na região Sul do Brasil. Mensuraram-se as variáveis antropométricas (massa corporal e estatura; a resistência e hidratação dos tecidos livres de gordura foram medidas pela técnica da BIA tetrapolar (Biodinamics - BF-310, e pela DXA de corpo inteiro (Lunar Prodigy DF + 14319 Radiation e software 7.52.002 DPX-L. A diferença entre os métodos foi verificada pelo teste t pareado, análise dos resíduos e o coeficiente de correlação. O valor preditivo das variáveis antropométricas e de BIA foi verificado pela regressão linear múltipla, adotando nível de significância de p 0,01. Observou-se que a BIA subestimou em média 0,8kg (IC95%: -3,7; 2,0kg a MME, quando comparada com a DXA. Foi observada alta correlação entre os métodos (r² = 0,75; p The objectives of the present study were: a to determine the agreement between bioelectrical impedance analysis (BIA and dual-energy X-ray absorptiometry (DXA for the estimation of skeletal muscle mass (SMM, and b to analyze the predictive power of anthropometric variables and BIA for the prediction of SMM in elderly women. A total of 120 women (60 to 81 years, living in the southern region of Brazil, were studied. Anthropometric variables (body weight and height were measured. Resistance and hydration of fat-free tissues were measured by tetrapolar BIA (Biodynamics, BF-310 and by whole-body DXA (Lunar Prodigy DF + 14319 Radiation and DPX-L software, version 7.52.002. Differences between methods were determined using the paired t-test, analysis of residuals and correlation coefficient. The predictive value of the

  9. Estimativa da gordura corporal através de equipamentos de bioimpedância, dobras cutâneas e pesagem hidrostática Comparison of body fat estimation by bioelectric impedance, skinfold thickness, and underwater weighing

    Directory of Open Access Journals (Sweden)

    Maurício Nunes Rodrigues

    2001-08-01

    Full Text Available A estimativa do percentual de gordura (%G pela bioimpedância (BIA tem como vantagem a simplicidade da medida. Contudo, a confiabilidade da BIA tem sofrido críticas. O objetivo deste estudo foi comparar a estimativa do %G através das técnicas de bioimpedância (RJL-101; Byodinamics A-310, Maltron BF-900 e BF-906, de dobras cutâneas (DC e da pesagem hidrostática (PH. Observaram-se 25 indivíduos, homogeneizados segundo raça (branca, gênero (masculino e idade (18 a 36 anos. Para a medida de BIA foi utilizada a padronização proposta por Lukaski et al. (1985, 1986. Para as DC foram utilizadas as equações de å 3 DC e å 7 DC (Jackson, Pollock, 1978. Os valores de %G e de volume residual para PH foram preditos, respectivamente, pelas equações de Siri (1961 e Goldman e Becklake (1959. A análise estatística compreendeu: a comparação entre os métodos através da ANOVA com medidas repetidas seguida de testes post-hoc de Tukey; b correlação de Pearson (r; e c cálculo do erro padrão de estimativa (SEE das técnicas em relação à PH. Os resultados indicaram que: a as medidas de BIA não diferiram significativamente, entre si, para o %G estimado; b As medidas dos aparelhos A-310 e BF-906 não coincidiram com a PH (p The main advantage of the bioelectric impedance method (BIA in the determination of body fat (%BF is the simplicity of the procedure. However, its accuracy and reliability have been criticized. The purpose of this study was to compare the %BF obtained by BIA (RJL-101; Biodynamics A-310, Maltron BF-900 e BF-906, by skinfold thickness (ST, and by underwater weighing (UW. Twenty-five subjects, divided in homogenous groups according to age (18 to 36 years, sex (men, and race (white participated in the study. BIA measures were taken using the Lukaski et al. standardization (1985,1986. ST was taken by using the equation of 3 and 7 skinfolds (Jackson, Pollock, 1978. The values of %BF and residual volume for the UW were estimated

  10. Impedance plethysmography: a new method for continuous muscle perfusion monitoring.

    Science.gov (United States)

    Concannon, M J; Stewart, D H; Welsh, C F; Puckett, C L

    1991-08-01

    Vigilant postoperative monitoring of the buried muscle flap is critical after free transfer because early diagnosis of vascular insufficiency is essential to allow prompt correction. We have identified a monitoring method utilizing needle electrodes and impedance plethysmography that gives a beat-to-beat representation of muscular perfusion. In 25 New Zealand White rabbits the gastrocnemius muscle was isolated on its vascular pedicle, and two intramuscular needle electrodes were placed. The instantaneous impedance changes of the muscle (corresponding to the pulsatile volume changes of perfusion) were measured and recorded. Using this representation of perfusion, an independent judge was able to correctly diagnose muscular ischemia 100 percent of the time (n = 25). Further, the judge was able to correctly distinguish the ischemia as arterial (n = 10) or venous (n = 10) in origin 100 percent of the time. Additionally, we monitored muscle perfusion transcutaneously in five free muscle flaps and demonstrated a reliable impedance signal that correlated with perfusion.

  11. Change in fat-free mass assessed by bioelectrical impedance, total body potassium and dual energy X-ray absorptiometry during prolonged weight loss

    DEFF Research Database (Denmark)

    Hendel, H W; Gotfredsen, A; Højgaard, L

    1996-01-01

    A total of 16 obese women (body mass index (BMI) 30-43 kg m(-2)) participated in a weight reduction study. Before and after a weight loss of 11.7 +/- 7.4 kg (mean +/- SD), body composition was assessed by dual energy X-ray absorptiometry (DXA), and total body potassium counting (TBK). These measu......A total of 16 obese women (body mass index (BMI) 30-43 kg m(-2)) participated in a weight reduction study. Before and after a weight loss of 11.7 +/- 7.4 kg (mean +/- SD), body composition was assessed by dual energy X-ray absorptiometry (DXA), and total body potassium counting (TBK......). These measurements were compared with bioimpedance analysis (BIA) by applying 11 predictive BIA equations published in the literature. Predictive equations for the present study population were developed, with the use of fat-free mass (FFM) as assessed by TBK and DXA as references in multiple regression analysis....... The results of the BIA equations varied widely; FFM was generally overestimated by BIA as compared with DXA and TBK before and after weight loss. During weight loss, the FFM did not change, as estimated by DXA (1.3 +/- 2.3 kg, p > 0.05) and TBK (0.9 +/- 2.9 kg, p > 0.05). The recorded change in impedance (R...

  12. NEW BIOTESTING METHOD WITH THE APPLICATION OF MODERN IMPEDANCE TECHNOLOGIES

    Directory of Open Access Journals (Sweden)

    Sibirtsev V.S.

    2015-03-01

    Full Text Available The paper deals with new concepts of biotesting method updating. Modern conductometric technologies and the analysis of microbial «growth curves» are used. The registration occurs in a real time mode for the set of parallel samples. Results are shown for comparison of the proposed impedance biotesting technique with standard cultural determination method for total amount of microorganismes in the tested samples. Results are presented for practical application of the proposed impedance biotesting technique to the analysis as inhibitory action of clorhexidine disinfectant on the vital activity of Escherichia coli, as milk ripening process at the presence of various microorganisms species and protein preparations. The impedance biotesting method, proposed in the present work, provides high level of its own data convergence with the data, being received as a result of application of standard cultural biotesting techniques. Thus, the proposed method has such advantages, as: an opportunity of the detailed information reception about dynamics change of magnitude of population and intensity of test microorganisms metabolism, significant reduction of the culture media amount used, as well as researcher's temporary and labor efforts while the analyses realization, and the growth of analysis objectivity.

  13. INFLUÊNCIA DE DIFERENTES TIPOS DE ELETRODOS SOBRE OS VALORES DA BIOIMPEDÂNCIA CORPORAL E NA ESTIMATIVA DE MASSA MAGRA (MM EM GATOS ADULTOS INFLUENCE OF DIFFERENT TYPES OF ELECTRODES ON THE BIOELECTRICAL IMPEDANCE VALUES AND IN THE ESTIMATION OF LEAN BODY MASS (LBM IN ADULT CATS

    Directory of Open Access Journals (Sweden)

    Thassila Caccia Feragi Cintra

    2010-04-01

    Full Text Available A bioimpedância (BIC é um método que aplica à tecnologia da impedância no estudo da composição corporal pela avaliação da diferença da condutividade elétrica dos tecidos. Os resultados da BIC são expressos pelas medidas primárias de resistência (R e reatância (Xc. Neste experimento, o método foi desenvolvido para verificar a viabilidade do uso de três diferentes tipos de eletrodos sobre a reprodutibilidade dos valores de R e Xc em gatos adultos. As médias de R e Xc com adesivos e agulhas de acupuntura não diferiram entre si (p?0,05, e os menores valores dos coeficientes de variação obtidos com estes eletrodos sinalizaram para uma melhor reprodutibilidade dos resultados quando comparados com os da agulha hipodérmica. Os diferentes tipos de eletrodos não interferiram nos valores da massa magra (MM estimada por equação específica, porém a agulha de acupuntura mostrou ser o eletrodo mais estável e de melhor aplicabilidade. A MM determinada com os diferentes tipos de eletrodos foi superior (p?0,05 à obtida com a absorciometria de raios-x de dupla energia (DEXA, provavelmente decorrente da equação utilizada na sua estimativa.

    PALAVRAS-CHAVES: Composição corporal, felinos, impedância, massa magra.
    The bioelectrical impedance is a method that applies impedance technology in the study of physical composition by evaluation of electrical conductivity difference on each organism tissue. The results of bioelectrical impedance (BIC are expressed by the resistance (R and reactance (Xc primary measures. This study was carried out to verify the viability of the use of three different electrodes on the repeatability of R and Xc values in adult cats. The averages of R and Xc estimated by adhesive and acupuncture needles did not differ from each other (p?0.05 and the smaller values of the variation coefficient acquired with these electrodes signaled for a better reproducibility of the results when compared with

  14. A dielectrophoresis-impedance method for protein detection and analysis

    Science.gov (United States)

    Mohamad, Ahmad Sabry; Hamzah, Roszymah; Hoettges, Kai F.; Hughes, Michael Pycraft

    2017-01-01

    Dielectrophoresis (DEP) has increasingly been used for the assessment of the electrical properties of molecular scale objects including proteins, DNA, nanotubes and nanowires. However, whilst techniques have been developed for the electrical characterisation of frequency-dependent DEP response, biomolecular study is usually limited to observation using fluorescent markers, limiting its applicability as a characterisation tool. In this paper we present a label-free, impedance-based method of characterisation applied to the determination of the electrical properties of colloidal protein molecules, specifically Bovine Serum Albumin (BSA). By monitoring the impedance between electrodes as proteins collect, it is shown to be possible to observe multi-dispersion behaviour. A DEP dispersion exhibited at 400 kHz is attributable to the orientational dispersion of the molecule, whilst a second, higher-frequency dispersion is attributed to a Maxwell-Wagner type dispersion; changes in behaviour with medium conductivity suggest that this is strongly influenced by the electrical double layer surrounding the molecule.

  15. Bioelectricity and epimorphic regeneration.

    Science.gov (United States)

    Stewart, Scott; Rojas-Muñoz, Agustin; Izpisúa Belmonte, Juan Carlos

    2007-11-01

    All cells have electric potentials across their membranes, but is there really compelling evidence to think that such potentials are used as instructional cues in developmental biology? Numerous reports indicate that, in fact, steady, weak bioelectric fields are observed throughout biology and function during diverse biological processes, including development. Bioelectric fields, generated upon amputation, are also likely to play a key role during vertebrate regeneration by providing the instructive cues needed to direct migrating cells to form a wound epithelium, a structure unique to regenerating animals. However, mechanistic insight is still sorely lacking in the field. What are the genes required for bioelectric-dependent cell migration during regeneration? The power of genetics combined with the use of zebrafish offers the best opportunity for unbiased identification of the molecular players in bioelectricity.

  16. Bioelectrical impedance for detecting and monitoring lymphedema in patients with breast cancer. Preliminary results of the florence nightingale breast study group.

    Science.gov (United States)

    Erdogan Iyigun, Zeynep; Selamoglu, Derya; Alco, Gul; Pilancı, Kezban Nur; Ordu, Cetin; Agacayak, Filiz; Elbüken, Filiz; Bozdogan, Atilla; Ilgun, Serkan; Guler Uysal, Fusun; Ozmen, Vahit

    2015-03-01

    The aim of this study was to evaluate the efficacy of bioimpedance spectroscopy for the follow-up of patients with lymphedema in Turkey and its benefits in the diagnosis of stage 0, 1, and 2 lymphedema in patients who are under treatment for breast cancer. Thirty-seven female patients with breast cancer who underwent surgical procedures in our Breast Health Centre were followed up for lymphedema using bioimpedance, and clinical measurements were taken for a minimum period of 1 year at 3-month intervals. Patients who had been monitored regularly between November, 2011, and September, 2013, were enrolled to the study. In total, 8 patients developed lymphedema with an overall rate of 21.6%. Among the 8 patients who developed lymphedema, 4 had Stage 2, 1 had Stage 1, and 3 had Stage 0 lymphedema. Stage 0 lymphedema could not be detected with clinical measurements. During the patients' 1-year follow-up period using measurements of bioimpedance, a statistically significant relationship was observed between the occurrence of lymphedema and the disease characteristics. including the number of the extracted and remaining lymph nodes and the region of radiotherapy (p=0.042, p=0.024, p=0.040). Bioimpedance analysis seems to be a practical and reliable method for the early diagnosis of lymphedema. It is believed that regular monitoring of patients in the high-risk group using bioimpedance analyses increases the ability to treat lymphedema.

  17. A comparison between handgrip strength, upper limb fat free mass by segmental bioelectrical impedance analysis (SBIA) and anthropometric measurements in young males

    Science.gov (United States)

    Gonzalez-Correa, C. H.; Caicedo-Eraso, J. C.; Varon-Serna, D. R.

    2013-04-01

    The mechanical function and size of a muscle may be closely linked. Handgrip strength (HGS) has been used as a predictor of functional performing. Anthropometric measurements have been made to estimate arm muscle area (AMA) and physical muscle mass volume of upper limb (ULMMV). Electrical volume estimation is possible by segmental BIA measurements of fat free mass (SBIA-FFM), mainly muscle-mass. Relationship among these variables is not well established. We aimed to determine if physical and electrical muscle mass estimations relate to each other and to what extent HGS is to be related to its size measured by both methods in normal or overweight young males. Regression analysis was used to determine association between these variables. Subjects showed a decreased HGS (65.5%), FFM, (85.5%) and AMA (74.5%). It was found an acceptable association between SBIA-FFM and AMA (r2 = 0.60) and poorer between physical and electrical volume (r2 = 0.55). However, a paired Student t-test and Bland and Altman plot showed that physical and electrical models were not interchangeable (ptanthropometric (r2 = 0.07) and electrical (r2 = 0.192) ULMMV showing that muscle mass quantity does not mean muscle strength. Other factors influencing HGS like physical training or nutrition require more research.

  18. Impedance adaptation methods of the piezoelectric energy harvesting

    Science.gov (United States)

    Kim, Hyeoungwoo

    In this study, the important issues of energy recovery were addressed and a comprehensive investigation was performed on harvesting electrical power from an ambient mechanical vibration source. Also discussed are the impedance matching methods used to increase the efficiency of energy transfer from the environment to the application. Initially, the mechanical impedance matching method was investigated to increase mechanical energy transferred to the transducer from the environment. This was done by reducing the mechanical impedance such as damping factor and energy reflection ratio. The vibration source and the transducer were modeled by a two-degree-of-freedom dynamic system with mass, spring constant, and damper. The transmissibility employed to show how much mechanical energy that was transferred in this system was affected by the damping ratio and the stiffness of elastic materials. The mechanical impedance of the system was described by electrical system using analogy between the two systems in order to simply the total mechanical impedance. Secondly, the transduction rate of mechanical energy to electrical energy was improved by using a PZT material which has a high figure of merit and a high electromechanical coupling factor for electrical power generation, and a piezoelectric transducer which has a high transduction rate was designed and fabricated. The high g material (g33 = 40 [10-3Vm/N]) was developed to improve the figure of merit of the PZT ceramics. The cymbal composite transducer has been found as a promising structure for piezoelectric energy harvesting under high force at cyclic conditions (10--200 Hz), because it has almost 40 times higher effective strain coefficient than PZT ceramics. The endcap of cymbal also enhances the endurance of the ceramic to sustain ac load along with stress amplification. In addition, a macro fiber composite (MFC) was employed as a strain component because of its flexibility and the high electromechanical coupling

  19. Studies of an Adaptive Kaczmarz Method for Electrical Impedance Imaging

    Science.gov (United States)

    Li, Taoran; Isaacson, David; Newell, Jonathan C.; Saulnier, Gary J.

    2013-04-01

    We present an adaptive Kaczmarz method for solving the inverse problem in electrical impedance tomography and determining the conductivity distribution inside an object from electrical measurements made on the surface. To best characterize an unknown conductivity distribution and avoid inverting the Jacobian-related term JTJ which could be expensive in terms of memory storage in large scale problems, we propose to solve the inverse problem by adaptively updating both the optimal current pattern with improved distinguishability and the conductivity estimate at each iteration. With a novel subset scheme, the memory-efficient reconstruction algorithm which appropriately combines the optimal current pattern generation and the Kaczmarz method can produce accurate and stable solutions adaptively compared to traditional Kaczmarz and Gauss-Newton type methods. Several reconstruction image metrics are used to quantitatively evaluate the performance of the simulation results.

  20. A parametric framework for modelling of bioelectrical signals

    CERN Document Server

    Mughal, Yar Muhammad

    2016-01-01

    This book examines non-invasive, electrical-based methods for disease diagnosis and assessment of heart function. In particular, a formalized signal model is proposed since this offers several advantages over methods that rely on measured data alone. By using a formalized representation, the parameters of the signal model can be easily manipulated and/or modified, thus providing mechanisms that allow researchers to reproduce and control such signals. In addition, having such a formalized signal model makes it possible to develop computer tools that can be used for manipulating and understanding how signal changes result from various heart conditions, as well as for generating input signals for experimenting with and evaluating the performance of e.g. signal extraction methods. The work focuses on bioelectrical information, particularly electrical bio-impedance (EBI). Once the EBI has been measured, the corresponding signals have to be modelled for analysis. This requires a structured approach in order to move...

  1. Primary report of noninvasive impedance monitoring of cerebral hematoma and edema in patients with intracerebral hemorrhage

    Institute of Scientific and Technical Information of China (English)

    Xia Yi Lu; Dong Wei-Wei; Yang Hao; Long Men; Yang Hua

    2000-01-01

    Background and Objective Brain edema is one of the most important clinical process in many diseases. Tissue impedance monitoring offers a non-invasive, bedside, rapid, and reliable technique for the monitoring of the brain edema. Methods We use a bioelectrical impedance(BEI) monitoring unit to record the brain impedance in the healthy volunteer and the patients with intracerebral hemorrhage. Percent of BEI variations were calculation. Results and Conclusions Brain BEI haven f any difference between both hemispheres in normal ones. In 48hrs, BEI value at hematoma-side was obviously decreased; after 48hrs, BEI value was obviously increased and continue to tenth day. Brain bioelectrical impedance monitoring, particularly noninvasively, is a first time in this field. The primary results show brain BEI could reflect the evolution of cerebral hematoma and edema.

  2. A method to separate process contributions in impedance spectra by variation of test conditions

    DEFF Research Database (Denmark)

    Jensen, Søren Højgaard; Hauch, Anne; Hendriksen, Peter Vang;

    2007-01-01

    Many processes contribute to the overall impedance of an electrochemical cell, and these may be difficult to separate in the impedance spectrum. Here, we present an investigation of a solid oxide fuel cell based on differences in impedance spectra due to a change of operating parameters and present...... the result as the derivative of the impedance with respect to ln(f). The method is used to separate the anode and cathode contributions and to identify various types of processes....

  3. Iterative Reconstruction Methods for Hybrid Inverse Problems in Impedance Tomography

    DEFF Research Database (Denmark)

    Hoffmann, Kristoffer; Knudsen, Kim

    2014-01-01

    For a general formulation of hybrid inverse problems in impedance tomography the Picard and Newton iterative schemes are adapted and four iterative reconstruction algorithms are developed. The general problem formulation includes several existing hybrid imaging modalities such as current density...... impedance imaging, magnetic resonance electrical impedance tomography, and ultrasound modulated electrical impedance tomography, and the unified approach to the reconstruction problem encompasses several algorithms suggested in the literature. The four proposed algorithms are implemented numerically in two...... be based on a theoretical analysis of the underlying inverse problem....

  4. Method of estimating pulse response using an impedance spectrum

    Energy Technology Data Exchange (ETDEWEB)

    Morrison, John L; Morrison, William H; Christophersen, Jon P; Motloch, Chester G

    2014-10-21

    Electrochemical Impedance Spectrum data are used to predict pulse performance of an energy storage device. The impedance spectrum may be obtained in-situ. A simulation waveform includes a pulse wave with a period greater than or equal to the lowest frequency used in the impedance measurement. Fourier series coefficients of the pulse train can be obtained. The number of harmonic constituents in the Fourier series are selected so as to appropriately resolve the response, but the maximum frequency should be less than or equal to the highest frequency used in the impedance measurement. Using a current pulse as an example, the Fourier coefficients of the pulse are multiplied by the impedance spectrum at corresponding frequencies to obtain Fourier coefficients of the voltage response to the desired pulse. The Fourier coefficients of the response are then summed and reassembled to obtain the overall time domain estimate of the voltage using the Fourier series analysis.

  5. An effective measured data preprocessing method in electrical impedance tomography.

    Science.gov (United States)

    Yu, Chenglong; Yue, Shihong; Wang, Jianpei; Wang, Huaxiang

    2014-01-01

    As an advanced process detection technology, electrical impedance tomography (EIT) has widely been paid attention to and studied in the industrial fields. But the EIT techniques are greatly limited to the low spatial resolutions. This problem may result from the incorrect preprocessing of measuring data and lack of general criterion to evaluate different preprocessing processes. In this paper, an EIT data preprocessing method is proposed by all rooting measured data and evaluated by two constructed indexes based on all rooted EIT measured data. By finding the optimums of the two indexes, the proposed method can be applied to improve the EIT imaging spatial resolutions. In terms of a theoretical model, the optimal rooting times of the two indexes range in [0.23, 0.33] and in [0.22, 0.35], respectively. Moreover, these factors that affect the correctness of the proposed method are generally analyzed. The measuring data preprocessing is necessary and helpful for any imaging process. Thus, the proposed method can be generally and widely used in any imaging process. Experimental results validate the two proposed indexes.

  6. Graph-Analytical Method of Determining Impedance in Electrical Transformers

    Directory of Open Access Journals (Sweden)

    Zorica Bogicevic

    2015-01-01

    Full Text Available This paper presents a graph-analytical method for determining the electrical impedance of alternate energy sources, especially small power transformers and current transformers in electric networks. Unlike conventional short-circuit and idle tests, according to proposed method, in this paper, transformer parameters are determined in a new way, which is based on measurement of voltages and currents on the active and reactive load (inductive or capacitive. The effectiveness of the proposed model was verified using an adapted simulation in the software package MATLAB Simulink. The simulation was performed for three types of ABB transformers with a 100% load. Simulation results were obtained for power transformers: Sn1=1 [MVA], Sn2=2 [MVA], Sn3=3.15 [MVA]. If we compare measurement result values of RT, XT, which are contained in a brochure for ABB transformers and those obtained through simulation, different tolerances are obtained. For reactance results, deviations are up to 20% for all three tested transformers. For results of active resistance tolerances are up to 5% for all three tested transformers. This method can be used not only to determine the active and inductive AC power source parameters but also to determine and analyze the impendence of electrical sources with high frequencies.

  7. Electromechanical impedance method to assess dental implant stability

    Science.gov (United States)

    Tabrizi, Aydin; Rizzo, Piervincenzo; Ochs, Mark W.

    2012-11-01

    The stability of a dental implant is a prerequisite for supporting a load-bearing prosthesis and establishment of a functional bone-implant system. Reliable and noninvasive methods able to assess the bone interface of dental and orthopedic implants (osseointegration) are increasingly demanded for clinical diagnosis and direct prognosis. In this paper, we propose the electromechanical impedance method as a novel approach for the assessment of dental implant stability. Nobel Biocare® implants with a size of 4.3 mm diameter ×13 mm length were placed inside bovine bones that were then immersed in a solution of nitric acid to allow material degradation. The degradation simulated the inverse process of bone healing. The implant-bone systems were monitored by bonding a piezoceramic transducer (PZT) to the implants’ abutment and measuring the admittance of the PZT over time. It was found that the PZT’s admittance and the statistical features associated with its analysis are sensitive to the degradation of the bones and can be correlated to the loss of calcium measured by means of the atomic absorption spectroscopy method. The present study shows promising results and may pave the road towards an innovative approach for the noninvasive monitoring of dental implant stability and integrity.

  8. Mutual Coupling Compensation for Direction-of-Arrival Estimations Using the Receiving-Mutual-Impedance Method

    Directory of Open Access Journals (Sweden)

    Hoi Shun Lui

    2010-01-01

    Full Text Available A short review of the receiving-mutual-impedance method (RMIM for mutual coupling compensation in direction finding applications using linear array is conducted. The differences between the conventional-mutual-impedance method (CMIM and RMIM, as well as the three different determination methods for receiving mutual impedance (RMI, will be discussed in details. As an example, direction finding with better accuracies is used for demonstrating the superiority of mutual coupling compensation using RMIM.

  9. Application of impedance spectroscopy method for analysis of benzanol fuels

    Directory of Open Access Journals (Sweden)

    Mamykin A. V.

    2015-06-01

    Full Text Available The authors have developed a method for express control of three component «gasoline-alcohol-water» fuel mixtures based on the spectral impedance investigation of benzanol mixture in the frequency range of 500 Hz — 10 kHz. A correlation dependence between the dielectric constant and the specific resistance of the fuel mixture on content of ethanol and water in the mixture has been found. On the basis of this dependence a calibration nomogram to quantify the gasoline and water-alcohol components content in the test benzanol fuel in the actual range of concentrations has been formed. The nomogram allows determining the water-alcohol and gasoline parts in the analyzed fuel with an error of no more than 1% vol., while the strength of water-alcohol solution is determined with an error of no more than 0.8% vol. The obtained nomogram can also give information about critical water content in the benzanol fuel to prevent its eventual phase separation. It is shown that the initial component composition of different gasoline brands has no significant effect on the electrical characteristics of the studied benzanol fuels, which makes the evaluation of alcohol and water content in the fuel sufficiently accurate. for practical applications.

  10. [A study of coordinates transform iterative fitting method to extract bio-impedance model parameters bio-impedance model parameters].

    Science.gov (United States)

    Zhou, Liming; Yang, Yuxing; Yuan, Shiying

    2006-02-01

    A new algorithm, the coordinates transform iterative optimizing method based on the least square curve fitting model, is presented. This arithmetic is used for extracting the bio-impedance model parameters. It is superior to other methods, for example, its speed of the convergence is quicker, and its calculating precision is higher. The objective to extract the model parameters, such as Ri, Re, Cm and alpha, has been realized rapidly and accurately. With the aim at lowering the power consumption, decreasing the price and improving the price-to-performance ratio, a practical bio-impedance measure system with double CPUs has been built. It can be drawn from the preliminary results that the intracellular resistance Ri increased largely with an increase in working load during sitting, which reflects the ischemic change of lower limbs.

  11. An Impedance-Based Stability Analysis Method for Paralleled Voltage Source Converters

    DEFF Research Database (Denmark)

    Wang, Xiongfei; Blaabjerg, Frede; Loh, Poh Chiang

    2014-01-01

    This paper analyses the stability of paralleled voltage source converters in AC distributed power systems. An impedance-based stability analysis method is presented based on the Nyquist criterion for multiloop system. Instead of deriving the impedance ratio as usual, the system stability...... is assessed based on a series of Nyquist diagrams drawn for the terminal impedance of each converter. Thus, the effect of the right half-plane zeros of terminal impedances in the derivation of impedance ratio for paralleled source-source converters is avoided. The interaction between the terminal impedance...... of converter and the passive network can also be predicted by the Nyquist diagrams. This method is applied to evaluate the current and voltage controller interactions of converters in both grid-connected and islanded operations. Simulations and experimental results verify the effectiveness of theoretical...

  12. Error Correction of EMTDC Line and Cable Series Impedance Calculations Compared to Traditional Methods

    DEFF Research Database (Denmark)

    Sørensen, Stefan; Nielsen, Hans Ove

    2002-01-01

    In this paper we present comparison of different line and cable series impedance calculation methods, where the correction of a discovered PSCAD/EMIDC v.3.0.8 calculation error of the cable series impedance results n deviation under 0.1% instead of the previous method which gave approximately 10%...

  13. A new monitoring method for electrochemical aggregates by impedance spectroscopy

    Science.gov (United States)

    Kurzweil, P.; Fischle, H.-J.

    A variant of ac impedance spectroscopy is applied to monitor and control electrochemical cells and appliances without need for reference values and knowledge of control points in advance. Electrolyzers, fuels cells, energy stores, sensors and electrochemical reactors are steered to an optimum operating state by continuous evaluation of capacitance and the derivatives thereof. Dry and humid electrode-electrolyte interfaces are distinguished with the aid of the low-frequency impedance. The problem is solved in order to determine electrolyte concentrations unambiguously from electrolyte resistance, although the conductivity of the solution has a maximum and changes nonlinearly with the concentration.

  14. Accurate position estimation methods based on electrical impedance tomography measurements

    Science.gov (United States)

    Vergara, Samuel; Sbarbaro, Daniel; Johansen, T. A.

    2017-08-01

    Electrical impedance tomography (EIT) is a technology that estimates the electrical properties of a body or a cross section. Its main advantages are its non-invasiveness, low cost and operation free of radiation. The estimation of the conductivity field leads to low resolution images compared with other technologies, and high computational cost. However, in many applications the target information lies in a low intrinsic dimensionality of the conductivity field. The estimation of this low-dimensional information is addressed in this work. It proposes optimization-based and data-driven approaches for estimating this low-dimensional information. The accuracy of the results obtained with these approaches depends on modelling and experimental conditions. Optimization approaches are sensitive to model discretization, type of cost function and searching algorithms. Data-driven methods are sensitive to the assumed model structure and the data set used for parameter estimation. The system configuration and experimental conditions, such as number of electrodes and signal-to-noise ratio (SNR), also have an impact on the results. In order to illustrate the effects of all these factors, the position estimation of a circular anomaly is addressed. Optimization methods based on weighted error cost functions and derivate-free optimization algorithms provided the best results. Data-driven approaches based on linear models provided, in this case, good estimates, but the use of nonlinear models enhanced the estimation accuracy. The results obtained by optimization-based algorithms were less sensitive to experimental conditions, such as number of electrodes and SNR, than data-driven approaches. Position estimation mean squared errors for simulation and experimental conditions were more than twice for the optimization-based approaches compared with the data-driven ones. The experimental position estimation mean squared error of the data-driven models using a 16-electrode setup was less

  15. Grado de acuerdo entre los índices adiposo-musculares obtenidos a partir de medidas antropométricas del brazo, pliegues cutáneos e impedancia bioeléctrica Interchangeability of the fat-to-fat-free mass ratios obtained by arm anthropometric measures, skinfold thickness and bioelectrical impedance

    Directory of Open Access Journals (Sweden)

    V. Martín Moreno

    2003-04-01

    agreement among the fat-to-fat-free mass ratios obtained by arm anthropometric measures (fat-muscle index, FMI, Siri equation for the sum of four skinfold thickness (body fat-muscle index, BFMI Siri and triceps skinfold (BFMItriceps and bioelectrical impedance (BFMI Omron methods. Methods: This is a cross-sectional study. A total of 145 patients were evaluated by anthropometry and bioelectrical impedance (Omron BF 300(, being estimated the agreement through the Intraclass Correlation Coefficient (ICC and Bland-Altman method. The reference method was BFMI Siri. Results: The ICC between BFMI Siri - BFMItriceps were 0,9304 (0,9035; 0,9498, between BFMI Siri - FMI of 0,7726 (0,6846; 0,8361 and between BFMI Siri - BFMI Omron of 0,9114 (0,8771; 0,9361. BFMItriceps (limits of agreement -0,171 to 0,117 show the best agreement according to Bland-Altman analysis with BFMI Siri, followed by BMFI Siri - BFMI Omron (-0,186; 0,178. The agreement limits between FMI and BFMI Siri (-0,2; 0,42, BFMItriceps (-0,26; 0,42 or BFMI Omron (-0,292; 0,504 were beyond of the established cut-off points (-0,2; 0,2. Conclusions: Due to the nature of the statistical agreement BFMItriceps and BFMI Omron are methods interchangeable methods between them and with BFMI Siri. FMI is not interchangeable with BFMI Siri, BFMI Omron or BFMItriceps. These results suggest that FMI cannot estimate properly the body composition. BFMItriceps and BFMI Omron are valid alternative methods to be used instead BFMI Siri in the fat-to-fat-free mass ratio assessment.

  16. Cable Overheating Risk Warning Method Based on Impedance Parameter Estimation in Distribution Network

    Science.gov (United States)

    Yu, Zhang; Xiaohui, Song; Jianfang, Li; Fei, Gao

    2017-05-01

    Cable overheating will lead to the cable insulation level reducing, speed up the cable insulation aging, even easy to cause short circuit faults. Cable overheating risk identification and warning is nessesary for distribution network operators. Cable overheating risk warning method based on impedance parameter estimation is proposed in the paper to improve the safty and reliability operation of distribution network. Firstly, cable impedance estimation model is established by using least square method based on the data from distribiton SCADA system to improve the impedance parameter estimation accuracy. Secondly, calculate the threshold value of cable impedance based on the historical data and the forecast value of cable impedance based on the forecasting data in future from distribiton SCADA system. Thirdly, establish risks warning rules library of cable overheating, calculate the cable impedance forecast value and analysis the change rate of impedance, and then warn the overheating risk of cable line based on the overheating risk warning rules library according to the variation relationship between impedance and line temperature rise. Overheating risk warning method is simulated in the paper. The simulation results shows that the method can identify the imedance and forecast the temperature rise of cable line in distribution network accurately. The result of overheating risk warning can provide decision basis for operation maintenance and repair.

  17. A New Method of On-line Grid Impedance Estimation for PV Inverter

    DEFF Research Database (Denmark)

    Teodorescu, Remus; Asiminoaei, Lucian; Blaabjerg, Frede

    2004-01-01

    for on-line measuring the grid impedance is presented. The presented method requires no extra hardware being accommodated by typical PV inverters, sensors and CPU, to provide a fast and low cost approach of on-line impedance measurement. By injecting a non-characteristic harmonic current and measuring...

  18. IMPEDANCE METHOD OF MEASURING OF THE TITRATABLE ACIDITY OF YOGURT

    Directory of Open Access Journals (Sweden)

    Miroslav Vasilev

    2016-10-01

    Full Text Available In the present work are analyzed studies related to changes in the active impedance component of the dairy environment caused by the flow of lactic fermentation and coagulation of casein in milk. The aim of this work was to determine the relationship between the relative change of titratable acidity and the relative change of active impedance component of the dairy environment with lactic fermentation, causing coagulation of the casein in milk. . The data were interpolated with cubic spline, visualizing how when the fat content increases, the electrical resistance increases too. All data, collected during the tests would complement and be used for solving the optimization problem to determine the time of completion of the coagulation in future work.

  19. An Analytical Method of Auxiliary Sources Solution for Plane Wave Scattering by Impedance Cylinders

    DEFF Research Database (Denmark)

    Larsen, Niels Vesterdal; Breinbjerg, Olav

    2004-01-01

    Analytical Method of Auxiliary Sources solutions for plane wave scattering by circular impedance cylinders are derived by transformation of the exact eigenfunction series solutions employing the Hankel function wave transformation. The analytical Method of Auxiliary Sources solution thus obtained...

  20. Anthropometric methods for obesity screening in schoolchildren; the Ouro Preto Study.

    OpenAIRE

    Cândido, Ana Paula Carlos; J. P. S. Alosta; C.T. Oliveira; Freitas, Renata Nascimento de; Freitas, Silvia Nascimento de; Coelho, George Luiz Lins Machado

    2012-01-01

    Background and aims: Childhood obesity is increasing dramatically in last decades. To evaluate the usefulness of body mass index (BMI), skinfold thickness (ST), waist circumference (WC), and foot-to-foot bioelectrical impe - dance (BIA-FF) for screening for obesity in mixed-race population, using the tetrapolar bioelectrical impedance (BIA-T) technique as reference method. Methods and results: A cross-sectional-based population study was performed in the city of Ouro Preto, Brazil, in 2006. S...

  1. Comparative Study of Impedance Eduction Methods, Part 2: NASA Tests and Methodology

    Science.gov (United States)

    Jones, Michael G.; Watson, Willie R.; Howerton, Brian M.; Busse-Gerstengarbe, Stefan

    2013-01-01

    A number of methods have been developed at NASA Langley Research Center for eduction of the acoustic impedance of sound-absorbing liners mounted in the wall of a flow duct. This investigation uses methods based on the Pridmore-Brown and convected Helmholtz equations to study the acoustic behavior of a single-layer, conventional liner fabricated by the German Aerospace Center and tested in the NASA Langley Grazing Flow Impedance Tube. Two key assumptions are explored in this portion of the investigation. First, a comparison of results achieved with uniform-flow and shear-flow impedance eduction methods is considered. Also, an approach based on the Prony method is used to extend these methods from single-mode to multi-mode implementations. Finally, a detailed investigation into the effects of harmonic distortion on the educed impedance is performed, and the results are used to develop guidelines regarding acceptable levels of harmonic distortion

  2. Recent advancements in the electromechanical (E/M) impedance method for structural health monitoring and NDE

    Science.gov (United States)

    Giurgiutiu, Victor; Rogers, Craig A.

    1998-07-01

    The emerging electro-mechanical impedance technology has high potential for in-situ health monitoring and NDE of structural systems and complex machinery. At first, the fundamental principles of the electro-mechanical impedance method are briefly reviewed and ways for practical implementation are highlighted. The equations of piezo- electric material response are given, and the coupled electro-mechanical impedance of a piezo-electric wafer transducer as affixed to the monitored structure is discussed. Due to the high frequency operation of this NDE method, wave propagation phenomena are identified as the primary coupling method between the structural substrate and the piezo-electric wafer transducer. Attention is then focused on several recent advancements that have extended the electro-mechanical impedance method into new areas of applications and/or have developed its underlying principles. US Army Construction Engineering Research Laboratory used the electro-mechanical impedance method to monitor damage development in composite overlaid civil infrastructure specimens under full-scale static testing. A simplified E/M impedance measuring technique was employed at the Polytechnic University of Madrid, Spain, to detect damage in GFRP composite specimens. The development of miniaturized `bare-bones' impedance analyzer equipment that could be easily packaged into transponder-size dimensions is being studied at the University of South Carolina. US Army Research Laboratory developed novel piezo-composite film transducers for embedment into composite structures. Disbond gauges for monitoring the structural joints of adhesively bonded rotor blades have been studies in the Mechanical Engineering Department at the University of South Carolina. These recent developments accentuate the importance and benefits of using the electro-mechanical impedance method for on-line health monitoring and damage detection in a variety of applications. Further investigation of the electro

  3. 多频生物电阻抗技术评价 COPD 患者营养状况及其与血气分析指标的相关性%Evaluation of Nutritional Status in COPD Patients by Multi - frequency Bioelectrical Impedance and Its Correlation With Blood Gas Indicators

    Institute of Scientific and Technical Information of China (English)

    黄陈; 朱文艺; 徐静; 李利; 樊荣; 李琦; 王建

    2015-01-01

    Objective To examine the body composition of COPD patients by multi - frequency bioelectrical impedance and investigate the relationship between body composition and blood gas indicators in order to provide clinical references for nutritional support for COPD patients. Methods We enrolled 62 patients who was hospitalized and diagnosed with COPD in the Department of Respiratory Medicine of Xinqiao Hospital from January to June in 2011. Multi - frequency bioelectrical impedance was used to detect the patients' physical composition. We collected data of serum total protein,albumin, prealbumin,hemoglobin,lymph cell count,blood gas( PaCO2 ,PaO2 and SpO2 ),HCO -3 ,Cl - ,K + ,Na + ,pH of the subjects at admission. Statistical analysis was conducted on the above indicators. Results The malnutrition rates assessed by ribosomal protein content,body fat content,BMI and MAC were 41. 9% ,17. 7% ,19. 4% and 16. 1% , respectively. According the BMI,the patients with inadequate,normal and excess nutrition were significantly different( P < 0. 05 )in ribosomal TBW,BFM,PBF,FFM,PBFF,protein content and PBP;the subjects with inadequate nutrition were higher(P <0. 05)than those with normal and high nutrition in PBP;the subjects with inadequate nutrition were lower( P < 0. 05)than those with normal and high nutrition in PBF and FFM. TBW,FFM,ribosomal protein,and SMM were negatively correlated with PaO2 ( r = - 0. 311, - 0. 306, - 0. 308, - 0. 306;P < 0. 05),and BMI was negatively correlated with SpO2 ( r =- 0. 304,P < 0. 05). Conclusion COPD patients have high malnutrition rate when assessed by ribosomal protein. FFM is more sensitive than BMI in nutritional evaluation of COPD patients. The increase of FFM in COPD patients may improve hypoxia tolerance.%目的:应用多频生物电阻抗技术分析 COPD 患者人体成分及其与血气分析指标的关系,为 COPD 患者的营养支持提供依据。方法选择2011年1—6月在新桥医院呼吸科住院并诊断为 COPD

  4. Circuits and methods for impedance determination using active measurement cancelation

    Energy Technology Data Exchange (ETDEWEB)

    Jamison, David K.

    2016-12-13

    A delta signal and opposite delta signal are generated such that a sum of the two signals is substantially zero. The delta signal is applied across a first set of electrochemical cells. The opposite delta signal is applied across a second set of electrochemical cells series connected to the first set. A first held voltage is established as the voltage across the first set. A second held voltage is established as the voltage across the second set. A first delta signal is added to the first held voltage and applied to the first set. A second delta signal is added to the second held voltage and applied to the second set. The current responses due to the added delta voltages travel only into the set associated with its delta voltage. The delta voltages and the current responses are used to calculate the impedances of their associated cells.

  5. Time-harmonic impedance tomography using the T-matrix method.

    Science.gov (United States)

    Otto, G P; Chew, W C

    1994-01-01

    A time-harmonic formulation for the electrical impedance tomography (EIT) inverse problem accounting for electrodynamic effects is derived. This work abandons the standard electrostatic impedance model for a full-wave T-matrix model. The advantage of this method is an accurate physical model that includes finite frequency effects, such as diffusion phenomena, and electrode contact impedance effects. This model offers the potential for increased resolution and larger invertible contrast objects than other methods when used on experimental data, because it may represent a more realistic physical model. Also, an accurate gradient matrix is used in the Newton iterative method so the image reconstruction converges in a few iterations. These advantages are realized with no increase in the computational complexity of this algorithm, compared to the static finite element model. A calibration technique is suggested for measurement systems, to test the validity of a theoretical model that includes electrode contact impedance effects.

  6. Assessment of calibration methods on impedance pneumography accuracy.

    Science.gov (United States)

    Młyńczak, Marcel; Niewiadomski, Wiktor; Żyliński, Marek; Cybulski, Gerard

    2016-12-01

    The aim was to assess accuracy of tidal volumes (TV) calculated by impedance pneumography (IP), reproducibility of calibration coefficients (CC) between IP and pneumotachometry (PNT), and their relationship with body posture, breathing rate and depth. Fourteen students performed three sessions of 18 series: normal and deep breathing at 6, 10, 15 breaths/min rates, while supine, sitting and standing; 18 CC were calculated for every session. Session 2 was performed 2 months after session 1, session 3 1-3 days after session 2. TV were calculated using full or limited set of CC from current session, in case of sessions 2 and 3 also using CC from session 1 and 2, respectively. When using full set of CC from current session, IP underestimated TV by -3.2%. Using CC from session 2 for session 3 measurements caused decrease of relative difference: -3.9%, from session 1 for session 2: -5.3%; for limited set of CC: -5.0%. The body posture had significant effect on CC. The highest accuracy was obtained when all factors influencing CC were considered. The application of CC related only to body posture may result in shortening of calibration and moderate accuracy loss. Using CC from previous session compromises accuracy moderately.

  7. A novel method for real-time skin impedance measurement during radiofrequency skin tightening treatments.

    Science.gov (United States)

    Harth, Yoram; Lischinsky, Daniel

    2011-03-01

    The thermal effects of monopolar and bipolar radiofrequency (RF) have been proven to be beneficial in skin tightening. Nevertheless, these effects were frequently partial or unpredictable because of the uncontrolled nature of monopolar or unipolar RF and the superficial nature of energy flow for bipolar or tripolar configurations. One of the hypotheses for lack or predictability of efficacy of the first-generation RF therapy skin tightening systems is lack of adaptation of delivered power to differences in individual skin impedance. A novel multisource phase-controlled system was used (1 MHz, power range 0-65 W) for treatment and real-time skin impedance measurements in 24 patients (EndyMed PRO™; EndyMed, Cesarea, Israel). This system allows continuous real-time measurement of skin impedance delivering constant energy to the patient skin independent of changes in its impedance. More than 6000 unique skin impedance measurements on 22 patients showed an average session impedance range was 215-584 Ohm with an average of 369 Ohm (standard deviation of 49 Ohm). Analyzing individual pulses (total of 600 readings) showed a significant decrease in impedance during the pulse. These findings validate the expected differences in skin impedance between individual patients and in the same patients during the treatment pulse. Clinical study on 30 patients with facial skin aging using the device has shown high predictability of efficacy (86.7% of patients had good results or better at 3 months' follow-up [decrease of 2 or more grades in Fitzpatrick's wrinkle scale]). The real-time customization of energy according to skin impedance allows a significantly more accurate and safe method of nonablative skin tightening with more consistent and predictable results. © 2011 Wiley Periodicals, Inc.

  8. Bioelectric Applications for Treatment of Melanoma

    Directory of Open Access Journals (Sweden)

    Richard Heller

    2010-09-01

    Full Text Available Two new cancer therapies apply bioelectric principles. These methods target tumor structures locally and function by applying millisecond electric fields to deliver plasmid DNA encoding cytokines using electrogene transfer (EGT or by applying rapid rise-time nanosecond pulsed electric fields (nsPEFs. EGT has been used to locally deliver cytokines such as IL-12 to activate an immune response, resulting in bystander effects. NsPEFs locally induce apoptosis-like effects and affect vascular networks, both promoting tumor demise and restoration of normal vascular homeostasis. EGT with IL-12 is in melanoma clinical trials and nsPEFs are used in models with B16F10 melanoma in vitro and in mice. Applications of bioelectrics, using conventional electroporation and extensions of it, provide effective alternative therapies for melanoma.

  9. Bioelectric Applications for Treatment of Melanoma

    Energy Technology Data Exchange (ETDEWEB)

    Beebe, Stephen J., E-mail: sbeebe@odu.edu; Schoenbach, Karl H.; Heller, Richard [Frank Reidy Research Center for Bioelectrics/Old Dominion University 4211 Monarch Way, Suite 300, Norfolk, Virginia 23508 (United States)

    2010-09-27

    Two new cancer therapies apply bioelectric principles. These methods target tumor structures locally and function by applying millisecond electric fields to deliver plasmid DNA encoding cytokines using electrogene transfer (EGT) or by applying rapid rise-time nanosecond pulsed electric fields (nsPEFs). EGT has been used to locally deliver cytokines such as IL-12 to activate an immune response, resulting in bystander effects. NsPEFs locally induce apoptosis-like effects and affect vascular networks, both promoting tumor demise and restoration of normal vascular homeostasis. EGT with IL-12 is in melanoma clinical trials and nsPEFs are used in models with B16F10 melanoma in vitro and in mice. Applications of bioelectrics, using conventional electroporation and extensions of it, provide effective alternative therapies for melanoma.

  10. Comparison of bioelectrical impedance with skinfold thickness and X-ray absorptiometry to measure body composition in HIV-infected with lipodistrophy Comparación de impendancia bioeléctrica con grosor de pliegues cutáneos y absorciometría de rayos X para mensurar la composición corporal de personas con VIH con lipodistrofia

    Directory of Open Access Journals (Sweden)

    H. Siqueira Vassimon

    2011-06-01

    Full Text Available Introduction: Human immunodeficiency vírus (HIV-associated lipodystrophy syndrome (LS includes body composition and metabolic alterations. Lack of validated criteria and tools make difficult to evaluate body composition in this group. Objective: The aim of the study was to compare different methods to evaluate body composition between Brazilians HIV subjects with (HIV+LIPO+ or without LS (HIV+LIPO- and healthy subjects (Control. Methods: in a cross-sectional analyses, body composition was measured by bioelectrical impedance analysis (BIA, skinfold thickness (SF and dual-energy x-ray absorptiometry (DXA in 10 subjects from HIV+LIPO+ group; 22 subjects from HIV+LIPO- group and 12 from Control group. Results: There were no differences in age and body mass index (BMI between groups. The fat mass (FM (% estimated by SF did not correlate with DXA in HIV+LIPO+ group (r = 0,46/ p > 0,05 and had fair agreement in both HIV groups (HIV+LIPO+ =0,35/ HIV+ LIPO- = 0,40. BIA had significant correlation in all groups (p Introducción: El síndrome de lipodistrofia (SL asociado al virus de inmunodeficiencia humana (HIV incluye alteraciones en la composición corporal y metabólica. La falta de herramientas adecuadas y criterios válidos dificultan la evaluación de la composición corporal en este grupo. Objetivo: El objetivo del estudio fue comparar distintos métodos para evaluar la composición corporal entre individuos brasileños con HIV que teniam (HIV+LIPO+ o no LS (HIV+LIPO- e individuos sanos (control. Métodos: Estudio transversal en el que fue evaluada la composición corporal por análisis de impedancia bioeléctrica (BIA, pliegues cutáneos (SF y absorciometría de rayos X de doble energía (DXA en un grupo de 10 individuos con HIV+LIPO+, 22 individuos del grupo HIV+ LIPO- y 12 individuos del grupo control. Resultados: No hubo diferencias en la edad e índice de masa corporal (IMC entre grupos. La masa grasa (MG (% estimada por SF no se correlacion

  11. A straightforward method for wall impedance eduction in a flow duct.

    Science.gov (United States)

    Jing, Xiaodong; Peng, Sen; Sun, Xiaofeng

    2008-07-01

    The development of the advanced liner technology for aeroengine noise control necessitates the impedance measurement method under realistic flow conditions. Currently, the methods for this need are mainly based on the inverse impedance eduction principle, confronting with the problems of initial guess, high computation cost, and low convergence. In view of this, a new strategy is developed that straightforwardly educes the impedance from the sound pressure information measured on the duct wall opposing to the test acoustic liner embedded in a flow duct. Here, the key insight is that the modal nature of the duct acoustic field renders a summed-exponential representation of the measured sound pressure; thus, the characterizing axial wave number can be readily extracted by means of Prony's method, and further the unknown impedance is calculated from the eigenvalue and dispersion relations based on the classical mode-decomposition analysis. This straightforward method is simple in its basic principle but remarkably has the advantages of ultimately overcoming the drawbacks inherent to the inverse methods, incorporating the realistic multimode nonprogressive wave effects, high computational efficiency, possibly reducing the measurement points, and even avoiding the necessity of the duct exit impedance that bothers perhaps all the existing waveguide methods.

  12. Transformerless High-Quality Electrocardiogram and Body Impedance Recording by an Amplifier with Current-Driven Inputs

    Directory of Open Access Journals (Sweden)

    Dobrev D.

    2009-12-01

    Full Text Available Measurement and recording of changes in bioelectrical impedance in vivo has become a widely used method with various clinical applications. It includes basal impedance Zo, relative changes ΔZ or its derivative dZ. Many applications related to cardiac and respiratory function require simultaneous electrocardiogram, impedance cardiogram and/or respiration signals recording and analysis. Accurate recording of body impedance is limited by high common mode voltages at the amplifier inputs combined with the influence of the output impedance of the used current source. A circuit concept for a simultaneous high-quality electrocardiogram and bioimpedance acquisition is proposed, profiting from advantages offered by a previously specially designed amplifier with current-driven inputs, yielding to low common mode and high differential mode input impedances.

  13. A New Method of Designing Electrical Impedance Matching Network for Piezoelectric Ultrasound Transducer

    Directory of Open Access Journals (Sweden)

    Jianfei An

    2014-01-01

    Full Text Available A new method that is based on genetic algorithm (GA is developed to design electrical impedance matching network for broadband piezoelectric ultrasound transducer. The new method can both optimize the topology of the matching network and perform optimization on the components at the same time. Results of classical algorithms are referenced to reduce the number of candidate topologies and greatly simplify the calculation process. Some calculation strategies, such as elitist strategy and clearing niche method, are adopted during optimization to make sure that the algorithm can convergence to global optimal result. Simulation results show that the new method has advantages over designing complex impedance matching network.

  14. Modeling of electrical impedance tomography to detect breast cancer by finite volume methods

    Science.gov (United States)

    Ain, K.; Wibowo, R. A.; Soelistiono, S.

    2017-05-01

    The properties of the electrical impedance of tissue are an interesting study, because changes of the electrical impedance of organs are related to physiological and pathological. Both physiological and pathological properties are strongly associated with disease information. Several experiments shown that the breast cancer has a lower impedance than the normal breast tissue. Thus, the imaging based on impedance can be used as an alternative equipment to detect the breast cancer. This research carries out by modelling of Electrical Impedance Tomography to detect the breast cancer by finite volume methods. The research includes development of a mathematical model of the electric potential field by 2D Finite Volume Method, solving the forward problem and inverse problem by linear reconstruction method. The scanning is done by 16 channel electrode with neighbors method to collect data. The scanning is performed at a frequency of 10 kHz and 100 kHz with three objects numeric includes an anomaly at the surface, an anomaly at the depth and an anomaly at the surface and at depth. The simulation has been successfully to reconstruct image of functional anomalies of the breast cancer at the surface position, the depth position or a combination of surface and the depth.

  15. On the Use of Experimental Methods to Improve Confidence in Educed Impedance

    Science.gov (United States)

    Jones, Michael G.; Watson, Willie R.

    2011-01-01

    Results from impedance eduction methods developed by NASA Langley Research Center are used throughout the acoustic liner community. In spite of recent enhancements, occasional anomalies persist with these methods, generally at frequencies where the liner produces minimal attenuation. This investigation demonstrates an experimental approach to educe impedance with increased confidence over a desired frequency range, by combining results from successive tests with different cavity depths. A series of tests is conducted with three wire-mesh facesheets, for which the results should be weakly dependent on source sound pressure level and mean grazing flow speed. First, a raylometer is used to measure the DC flow resistance of each facesheet. These facesheets are then mounted onto a frame and a normal incidence tube is used to determine their respective acoustic impedance spectra. A comparison of the acoustic resistance component with the DC flow resistance for each facesheet is used to validate the measurement process. Next, each facesheet is successively mounted onto three frames with different cavity depths, and a grazing flow impedance tube is used to educe their respective acoustic impedance spectra with and without mean flow. The no-flow results are compared with those measured in the normal incidence tube to validate the impedance eduction method. Since the anti-resonance frequency varies with cavity depth, each sample provides robust results over a different frequency range. Hence, a combination of results can be used to determine the facesheet acoustic resistance. When combined with the acoustic reactance, observed to be weakly dependent on the source sound pressure level and grazing flow Mach number, the acoustic impedance can be educed with increased confidence. Representative results of these tests are discussed, and the complete database is available in electronic format upon request.

  16. Comparative Study of Impedance Eduction Methods. Part 1; DLR Tests and Methodology

    Science.gov (United States)

    Busse-Gerstengarbe, Stefan; Bake, Friedrich; Enghardt, Lars; Jones, Michael G.

    2013-01-01

    The absorption efficiency of acoustic liners used in aircraft engines is characterized by the acoustic impedance. World wide, many grazing ow test rigs and eduction methods are available that provide values for that impedance. However, a direct comparison and assessment of the data of the di erent rigs and methods is often not possible because test objects and test conditions are quite di erent. Only a few papers provide a direct comparison. Therefore, this paper together with a companion paper, present data measured with a reference test object under similar conditions in the DLR and NASA grazing ow test rigs. Additionally, by applying the in-house methods Liner Impedance Non-Uniform ow Solving algorithm (LINUS, DLR) and Convected Helmhholtz Equation approach (CHE, NASA) on the data sets, similarities and differences due to underlying theory are identi ed and discussed.

  17. Validation of expedient methods for measuring body composition in Indian adults.

    Science.gov (United States)

    Kuriyan, R; Petracchi, C; Ferro-Luzzi, A; Shetty, P S; Kurpad, A V

    1998-01-01

    The body composition of 99 men and 89 women from south India was estimated using hydrodensitometry, bioelectrical impedance and skinfold thickness. Comparisons of the hydrodensitometry (reference method) and skinfold methods showed that there were no significant differences between the methods, for estimates of fat free mass (FFM) and per cent fat. The mean difference between the estimates FFM (bias), from skinfold measurement and hydrodensitometry was small for both groups (+0.16 +/- 1.09 kg in men and +0.67 +/- 0.9 kg in women). The same trend was observed in per cent fat estimates (-0.37 +/- 2.04 in men and -1.49 +/- 2.28 in women), showing that the skinfold method can be used as an accurate and expedient method to determine body composition. The bioelectrical impedance method obtained a significantly lower FFM and higher body fat than the reference (hydrodensitometry) method. This could have been due to the use of an inappropriate equation derived from Western population studies. Hence, a new predictive equation, for the measurement of FFM by the bioelectrical impedance method was derived for this population, using the variables of height2/impedance and FFM measured by underwater weighing. The new equation for the bioelectrical impedance method then gave values of body composition which compared well (0.26 +/- 2.32 kg) in men and (0.36 +/- 2.49 kg) in women with the hydrodensitometry method.

  18. An approach to the diagnosis of metabolic syndrome by the multi-electrode impedance method

    Science.gov (United States)

    Furuya, N.; Sakamoto, K.; Kanai, H.

    2010-04-01

    It is well known that metabolic syndrome can induce myocardial infarction and cerebral infarction. So, it is very important to measure the visceral fat volume. In the electric impedance method, information in the vicinity of the electrodes is strongly reflected. Therefore, we propose a new multi-electrode arrangement method based on the impedance sensitivity theorem to measure the visceral fat volume. This electrode arrangement is designed to enable high impedance sensitivity in the visceral and subcutaneous fat regions. Currents are simultaneously applied to several current electrodes on the body surface, and one voltage electrode pair is arranged on the body surface near the organ of interest to obtain the visceral fat information and another voltage electrode pair is arranged on the body surface near the current electrodes to obtain the subcutaneous fat information. A simulation study indicates that by weighting the impedance sensitivity distribution, as in our method, a high-sensitivity region in the visceral and the subcutaneous fat regions can be formed. In addition, it was confirmed that the visceral fat volume can be estimated by the measured impedance data.

  19. Electrical impedance tomography method for reconstruction of biological tissues with continuous plane-stratification.

    Science.gov (United States)

    Dolgin, M; Einziger, P D

    2006-01-01

    A novel electrical impedance tomography method is introduced for reconstruction of layered biological tissues with continuous plane-stratification. The algorithm implements the recently proposed reconstruction scheme for piecewise constant conductivity profiles, based on an improved Prony method in conjunction with Legendre polynomial expansion (LPE). It is shown that the proposed algorithm is capable of successfully reconstructing continuous conductivity profiles with moderate (WKB) slop. Features of the presented reconstruction scheme include, an inherent linearity, achieved by the linear LPE transform, a locality feature, assigning analytically to each spectral component a local electrical impedance associated with a unique location, and effective performance even in the presence of noisy measurements.

  20. Investigation of low frequency electrolytic solution behavior with an accurate electrical impedance method

    Science.gov (United States)

    Ho, Kung-Chu; Su, Vin-Cent; Huang, Da-Yo; Lee, Ming-Lun; Chou, Nai-Kuan; Kuan, Chieh-Hsiung

    2017-01-01

    This paper reports the investigation of strong electrolytic solutions operated in low frequency regime through an accurate electrical impedance method realized with a specific microfluidic device and high resolution instruments. Experimental results show the better repeatability and accuracy of the proposed impedance method. Moreover, all electrolytic solutions appear the so-called relaxation frequency at each peak value of dielectric loss due to relaxing total polarization inside the device. The relaxation frequency of concentrated electrolytes becomes higher owing to the stronger total polarization behavior coming from the higher conductivity as well as the lower resistance in the electrolytic solutions.

  1. The complex equivalent source method for sound propagation over an impedance plane.

    Science.gov (United States)

    Ochmann, Martin

    2004-12-01

    The sound field caused by a monopole source above an impedance plane can be calculated by using a superposition of equivalent point sources located along a line in the mirror space below the plane. Originally, such an approach for representing the half-space Green's function was described by Sommerfeld at the beginning of the last century, in order to treat half-space problems of heat conduction. However, the representation converges only for masslike impedances and cannot be used for the more important case of reflecting planes with springlike surface impedances. The singular part of the line integral can be transformed into a Hankel function, which shows that surface waves are contained in the whole solution. Unfortunately, this representation suffers from the lack of validity at certain receiver points and from restrictions on wave number and impedance range to ensure the necessary convergence. The main idea of the present method is to use also a superposition of equivalent point sources, but to allow that these sources can be located at complex source points. The corresponding form of the half-space Green's function is suitable for both masslike and springlike surface impedances, and can be used as a cornerstone for a boundary element method.

  2. Electrical impedance tomography methods for miniaturised 3D systems

    DEFF Research Database (Denmark)

    Canali, Chiara; Aristovich, K.; Ceccarelli, Lorenzo

    2016-01-01

    chambers (Ø 10 mm), each having eight gold plated needle electrodes vertically integrated along the chamber perimeter. As first method, the adjacent electrode configuration was tested solving the computationally simple back-projection algorithm using Comsol Multiphysics in time-difference EIT (t...

  3. Experimental facility and void fraction calibration methods for impedance probes

    Energy Technology Data Exchange (ETDEWEB)

    Oliveira, Fernando L. de; Rocha, Marcelo S., E-mail: floliveira@ipen.br, E-mail: msrocha@ipen.br [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)

    2013-07-01

    An experimental facility was designed and constructed with aims of to calibrate a capacitance probe for gas-liquid flow void fraction measurements. The facility is composed of a metallic hack with a vertical 2,300 mm high glass tube with 38 mm ID with stagnant water and compressed air bubbling system simulating the gas phase (vapor). At the lower part, a mixing section with a porous media element releases the air bubbles into the water, and the compressed air flow is measured by two calibrated rotameters. At the upper part a stagnant water tank separates the liquid and gas. Two pressure taps are located near the lower and upper sides of the glass tube for pressure difference measurement. The pressure difference is used for low void fraction values (0-15%) calibration methods, as described in the work. Two electrically controlled quick closing valves are installed between the porous media element and the upward separation tank for high void fraction values measurement (15-50%) used to calibrate the capacitance probe. The experimental facility design, construction, capacitance probe calibration methods and results, as well as flow pattern visualization, are presented. Finally, the capacitance probe will be installed on a natural circulation circuit mounted at the Nuclear Engineering Center (CEN/IPEN/CNEN-SP) for measurement of the instantaneous bulk void. Instantaneous signals generated by the capacitance probe will allow the determination of natural circulation loop global energy balance. (author)

  4. New equivalent-electrical circuit model and a practical measurement method for human body impedance.

    Science.gov (United States)

    Chinen, Koyu; Kinjo, Ichiko; Zamami, Aki; Irei, Kotoyo; Nagayama, Kanako

    2015-01-01

    Human body impedance analysis is an effective tool to extract electrical information from tissues in the human body. This paper presents a new measurement method of impedance using armpit electrode and a new equivalent circuit model for the human body. The lowest impedance was measured by using an LCR meter and six electrodes including armpit electrodes. The electrical equivalent circuit model for the cell consists of resistance R and capacitance C. The R represents electrical resistance of the liquid of the inside and outside of the cell, and the C represents high frequency conductance of the cell membrane. We propose an equivalent circuit model which consists of five parallel high frequency-passing CR circuits. The proposed equivalent circuit represents alpha distribution in the impedance measured at a lower frequency range due to ion current of the outside of the cell, and beta distribution at a high frequency range due to the cell membrane and the liquid inside cell. The calculated values by using the proposed equivalent circuit model were consistent with the measured values for the human body impedance.

  5. Bioelectrical Perchlorate Remediation

    Science.gov (United States)

    Thrash, C.; Achenbach, L. A.; Coates, J. D.

    2007-12-01

    Several bioreactor designs are currently available for the ex-situ biological attenuation of perchlorate- contaminated waters and recently, some of these reactor designs were conditionally approved by the California Department of Health Services for application in the treatment of perchlorate contaminated drinking water. However, all of these systems are dependent on the continual addition of a chemical electron donor to sustain microbial activity and are always subject to biofouling and downstream water quality issues. In addition, residual labile electron donor in the reactor effluent can stimulate microbial growth in water distribution systems and contribute to the formation of potentially toxic trihalomethanes during disinfection by chlorination. As part of our ongoing studies into microbial perchlorate reduction we investigated the ability of dissimilatory perchlorate reducing bacteria (DPRB) to metabolize perchlorate using a negatively charged electrode (cathode) in the working chamber of a bioelectrical reactor (BER) as the primary electron donor. In this instance the DPRB use the electrons on the electrode surface either directly or indirectly in the form of electrolytically produced H2 as a source of reducing equivalents for nitrate and perchlorate reduction. As part of this investigation our fed-batch studies showed that DPRB could use electrons from a graphite cathode poised at -500mV (vs. Ag/AgCl) for the reduction of perchlorate and nitrate. We isolated a novel organism, Dechlorospirillum strain VDY, from the cathode surface after 70 days operation which readily reduced 100 mg.L-1 perchlorate in a mediatorless batch bioelectrical reactor (BER) in 6 days. Continuous up-flow BERs (UFBERs) seeded with active cultures of strain VDY continuously treated waters containing 100 mg.L-1 perchlorate with almost 100% efficiency throughout their operation achieving a non-optimized volumetric loading of 60 mg.L-1 reactor volume.day-1. The same UFBERs also treated

  6. Impedance ratio method for urine conductivity-invariant estimation of bladder volume

    Directory of Open Access Journals (Sweden)

    Thomas Schlebusch

    2014-09-01

    Full Text Available Non-invasive estimation of bladder volume could help patients with impaired bladder volume sensation to determine the right moment for catheterisation. Continuous, non-invasive impedance measurement is a promising technology in this scenario, although influences of body posture and unknown urine conductivity limit wide clinical use today. We studied impedance changes related to bladder volume by simulation, in-vitro and in-vivo measurements with pigs. In this work, we present a method to reduce the influence of urine conductivity to cystovolumetry and bring bioimpedance cystovolumetry closer to a clinical application.

  7. Absorption and impedance boundary conditions for phased geometrical-acoustics methods

    DEFF Research Database (Denmark)

    Jeong, Cheol-Ho

    2012-01-01

    developed on which boundary condition produces accurate results. In this study, various boundary conditions in terms of normal, random, and field incidence absorption coefficients and normal incidence surface impedance are used in a phased beam tracing model, and the simulated results are validated...... with boundary element solutions. Two rectangular rooms with uniform and non-uniform absorption distributions are tested. Effects of the neglect of reflection phase shift are also investigated. It is concluded that the impedance, random incidence, and field incidence absorption boundary conditions produce......Defining accurate acoustical boundary conditions is of crucial importance for room acoustic simulations. In predicting sound fields using phased geometrical acoustics methods, both absorption coefficients and surface impedances of the boundary surfaces can be used, but no guideline has been...

  8. Absorption and impedance boundary conditions for phased geometrical-acoustics methods.

    Science.gov (United States)

    Jeong, Cheol-Ho

    2012-10-01

    Defining accurate acoustical boundary conditions is of crucial importance for room acoustic simulations. In predicting sound fields using phased geometrical acoustics methods, both absorption coefficients and surface impedances of the boundary surfaces can be used, but no guideline has been developed on which boundary condition produces accurate results. In this study, various boundary conditions in terms of normal, random, and field incidence absorption coefficients and normal incidence surface impedance are used in a phased beam tracing model, and the simulated results are validated with boundary element solutions. Two rectangular rooms with uniform and non-uniform absorption distributions are tested. Effects of the neglect of reflection phase shift are also investigated. It is concluded that the impedance, random incidence, and field incidence absorption boundary conditions produce reasonable results with some exceptions at low frequencies for acoustically soft materials.

  9. Method, system and computer-readable media for measuring impedance of an energy storage device

    Energy Technology Data Exchange (ETDEWEB)

    Morrison, John L.; Morrison, William H.; Christophersen, Jon P.; Motloch, Chester G.

    2016-01-26

    Real-time battery impedance spectrum is acquired using a one-time record. Fast Summation Transformation (FST) is a parallel method of acquiring a real-time battery impedance spectrum using a one-time record that enables battery diagnostics. An excitation current to a battery is a sum of equal amplitude sine waves of frequencies that are octave harmonics spread over a range of interest. A sample frequency is also octave and harmonically related to all frequencies in the sum. A time profile of this sampled signal has a duration that is a few periods of the lowest frequency. A voltage response of the battery, average deleted, is an impedance of the battery in a time domain. Since the excitation frequencies are known and octave and harmonically related, a simple algorithm, FST, processes the time profile by rectifying relative to sine and cosine of each frequency. Another algorithm yields real and imaginary components for each frequency.

  10. Application of the Method of Auxiliary Sources for the Analysis of Electromagnetic Scattering by Impedance Spheres

    DEFF Research Database (Denmark)

    Karamehmedovic, Mirza; Breinbjerg, Olav

    2002-01-01

    The Method of Auxiliary Sources (MAS) is applied to 3D scattering problems involving spherical impedance scatterers. The MAS results are compared with the reference spherical wave expansion (SWE) solution. It is demonstrated that good agreement is achieved between the MAS and SWE results....

  11. Electrical impedance spectroscopy and diagnosis of tendinitis.

    Science.gov (United States)

    Yoon, Kisung; Lee, Kyeong Woo; Kim, Sang Beom; Han, Tai Ryoon; Jung, Dong Keun; Roh, Mee Sook; Lee, Jong Hwa

    2010-02-01

    There have been a number of studies that investigate the usefulness of bioelectric signals in diagnoses and treatment in the medical field. Tendinitis is a musculoskeletal disorder with a very high rate of occurrence. This study attempts to examine whether electrical impedance spectroscopy (EIS) can detect pathological changes in a tendon and find the exact location of the lesion. Experimental tendinitis was induced by injecting collagenase into one side of the patellar tendons in rabbits, while the other side was used as the control. After measuring the impedance in the tendinitis and intact tendon tissue, the dissipation factor was computed. The real component of impedance and the dissipation factor turned out to be lower in tendinitis than in intact tissues. Moreover, the tendinitis dissipation factor spectrum showed a clear difference from that of the intact tendon, indicating its usefulness as a tool for detecting the location of the lesion. Pathologic findings from the tissues that were obtained after measuring the impedance confirmed the presence of characteristics of tendinitis. In conclusion, EIS is a useful method for diagnosing tendinitis and detecting the lesion location in invasive treatment.

  12. In vivo assessment of the impedance ratio method used in electronic foramen locators

    Directory of Open Access Journals (Sweden)

    Rambo Marcos VH

    2010-09-01

    Full Text Available Abstract Background The results of an in vivo study on the "ratio method" used in electronic foramen locators (EFL are presented. EFLs are becoming widely used in the determination of the working length (WL during the root canal treatment. The WL is the distance from a coronal reference point to the point at which canal preparation and filling should terminate. The "ratio method" was assessed by many clinicians with the aim of determining its ability to locate the apical foramen (AF. Nevertheless, in vivo studies to assess the method itself and to explain why the "ratio method" is able to locate the apical foramen and is unable to determine intermediate distances were not published so far. Methods A developed apparatus applies an electrical current signal with constant amplitude of 10 μARMS through the endodontic file within the root canal. The applied current signal is composed by summing six sine waves, from 250 Hz to 8 kHz. Data were acquired with the endodontic file tip at 7 different positions within root canals. In the frequency domain the quotients between the amplitude of a reference frequency and the amplitudes of the other frequencies components were calculated. Twenty one root canals were analyzed in vivo, during the endodontic treatment of twelve teeth of different patients, with age between 20 to 55 years. Results For the range of frequencies used in the commercial EFLs and for distances ranging from -3 mm to -1 mm of the AF, the impedance of the root canal is mainly resistive. However, when the file tip gets closer to AF, the root canal electrical impedance starts to change from a mainly resistive to a complex impedance. This change in the measured root canal impedance starts when the file tip is near -1.0 mm from the AF, getting stronger as the file tip gets closer to the AF. This change in the impedance behavior affects the ratio (quotient of the impedance measured at different frequencies. Through graphic analysis it is

  13. Pulse wave detection method based on the bio-impedance of the wrist

    Science.gov (United States)

    He, Jianman; Wang, Mengjun; Li, Xiaoxia; Li, Gang; Lin, Ling

    2016-05-01

    The real-time monitoring of pulse rate can evaluate the heart health to some extent, and the measurement of bio-impedance has the potential in wearable health monitoring system. In this paper, an effective method, which contains self-balancing bridge, flexible electrode, and high-speed digital lock-in algorithm (DLIA) with over-sampling, was designed to detect the impedance pulse wave at the wrist. By applying the self-balancing bridge, the basic impedance can be compensated as much as possible, and the low amplitude of impedance variation related to heart pulse can be obtained more easily. And the flexible conductive rubber electrode used in our experiment is human-friendly. Besides, the over-sampling method and high-speed DLIA are used to enhance the effective resolution of the existing data sampled by analog to digital converter. With the high-speed data process and simple circuit above, this proposed method has the potential in wrist-band wearable systems and it can satisfy quests of small volume and low power consumption.

  14. Grid impedance estimation based hybrid islanding detection method for AC microgrids

    DEFF Research Database (Denmark)

    Ghzaiel, Walid; Jebali-Ben Ghorbal, Manel; Slama-Belkhodja, Ilhem;

    2017-01-01

    This paper focuses on a hybrid islanding detection algorithm for parallel-inverters-based microgrids. The proposed algorithm is implemented on the unit ensuring the control of the intelligent bypass switch connecting or disconnecting the microgrid from the utility. This method employs a grid impe...... that the resonance excitation is canceled and the resistive and inductive grid impedance parts are estimated. Simulation results are carried out to illustrate the effectiveness of the proposed method....

  15. Development and Demonstration of Measurement-Time Efficient Methods for Impedance Spectroscopy of Electrode and Sensor Arrays

    OpenAIRE

    Derek Johnson; Matthew Smith; Kevin R. Cooper

    2008-01-01

    The development of impedance-based array devices is hindered by a lack of robust platforms and methods upon which to evaluate and interrogate sensors. One aspect to be addressed is the development of measurement-time efficient techniques for broadband impedance spectroscopy of large electrode arrays. The objective of this work was to substantially increase the low frequency impedance measurement throughput capability of a large channel count array analyzer by developing true parallel measurem...

  16. A study on calculation method for mechanical impedance of air spring

    Science.gov (United States)

    Changgeng, SHUAI; Penghui, LI; Rustighi, Emiliano

    2016-09-01

    This paper proposes an approximate analytic method of obtaining the mechanical impedance of air spring. The sound pressure distribution in cylindrical air spring is calculated based on the linear air wave theory. The influences of different boundary conditions on the acoustic pressure field distribution in cylindrical air spring are analysed. A 1-order ordinary differential matrix equation for the state vector of revolutionary shells under internal pressure is derived based on the non-moment theory of elastic thin shell. Referring to the transfer matrix method, a kind of expanded homogeneous capacity high precision integration method is introduced to solve the non-homogeneous matrix differential equation. Combined the solved stress field of shell with the calculated sound pressure field in air spring under the displacement harmonic excitation, the approximate analytical expression of the input and transfer mechanical impedance for the air spring can be achieved. The numerical simulation with the Comsol Multiphysics software verifies the correctness of theoretical analysis result.

  17. Estimation of pressure-particle velocity impedance measurement uncertainty using the Monte Carlo method.

    Science.gov (United States)

    Brandão, Eric; Flesch, Rodolfo C C; Lenzi, Arcanjo; Flesch, Carlos A

    2011-07-01

    The pressure-particle velocity (PU) impedance measurement technique is an experimental method used to measure the surface impedance and the absorption coefficient of acoustic samples in situ or under free-field conditions. In this paper, the measurement uncertainty of the the absorption coefficient determined using the PU technique is explored applying the Monte Carlo method. It is shown that because of the uncertainty, it is particularly difficult to measure samples with low absorption and that difficulties associated with the localization of the acoustic centers of the sound source and the PU sensor affect the quality of the measurement roughly to the same extent as the errors in the transfer function between pressure and particle velocity do.

  18. Calculation of coherent synchrotron radiation impedance using the mode expansion method

    Directory of Open Access Journals (Sweden)

    G. V. Stupakov

    2009-10-01

    Full Text Available We study an impedance due to coherent synchrotron radiation (CSR generated by a short bunch of charged particles passing through a dipole magnet of finite length in a vacuum chamber of a given cross section. In our method we decompose the electromagnetic field of the beam over the eigenmodes of the toroidal chamber and derive a system of equations for the expansion coefficients in the series. The general method is further specialized for a toroidal vacuum chamber of a rectangular cross section where the eigenmodes can be computed analytically. We also develop a computer code that calculates the CSR impedance for a toroid of rectangular cross section. Numerical results obtained with the code are presented in the paper.

  19. Development of a new salmon salting smoking method and process monitoring by impedance spectroscopy

    OpenAIRE

    Rizo Parraga, Arancha Maria; Fuentes López, Ana; Fernández Segovia, Isabel; Masot Peris, Rafael; Alcañiz Fillol, Miguel; Barat Baviera, José Manuel

    2013-01-01

    [EN] In this work two objectives were proposed: (i) to optimize a new salmon salting smoking method using vacuum packaging and (ii) to evaluate the application of impedance spectroscopy (IS) to the on-line monitoring of the process. Different processing conditions were evaluated (4 smoke flavoring (SF) salt concentrations, 3 salting times, salting in vacuum or in air). Physico-chemical analyses and IS measurements were performed with three different sensors during the process. Salting with 16...

  20. A method to detect heart rate based on electrical bio-impedance

    Directory of Open Access Journals (Sweden)

    Li Kun-Yang

    2016-01-01

    Full Text Available As a basic health indicator, heart rate has been widely used in clinical measurement and daily health care. Electrical bio-impedance (EBI measurement provides non-invasive method for heart rate detection. Therefore, this paper proposed a method to detect heart rate based on EBI. With the BIOPAC EBI module, the signal can be de-noised in real-time. Finally, the de-noised EBI signal is used to compute heart rate. Four electrodes are located at radial artery of left upper limb in this method. The result proves that this method has high accuracy on heart rate measurement.

  1. A Convergent Method of Auxiliary Sources for Two-Dimensional Impedance Scatterers With Edges

    DEFF Research Database (Denmark)

    Karamehmedovic, Mirza; Breinbjerg, Olav

    2001-01-01

    A modification to the Method of Auxiliary Sources (MAS) is introduced which renders the method operational for two-dimensional impedance scatterers with edges. The modification consists in letting the auxiliary surface converge to the scatterer physical surface for increasing number of auxiliary...... sources, whereby MAS approaches a surface integral equation (IE) method. Hereby, a systematic procedure for selecting the number and locations of the auxiliary sources is provided, and convergence of numerical results is obtained. The new method resulting from this modification thus combines the desirable...

  2. A new lithium-ion battery internal temperature on-line estimate method based on electrochemical impedance spectroscopy measurement

    Science.gov (United States)

    Zhu, J. G.; Sun, Z. C.; Wei, X. Z.; Dai, H. F.

    2015-01-01

    The power battery thermal management problem in EV (electric vehicle) and HEV (hybrid electric vehicle) has been widely discussed, and EIS (electrochemical impedance spectroscopy) is an effective experimental method to test and estimate the status of the battery. Firstly, an electrochemical-based impedance matrix analysis for lithium-ion battery is developed to describe the impedance response of electrochemical impedance spectroscopy. Then a method, based on electrochemical impedance spectroscopy measurement, has been proposed to estimate the internal temperature of power lithium-ion battery by analyzing the phase shift and magnitude of impedance at different ambient temperatures. Respectively, the SoC (state of charge) and temperature have different effects on the impedance characteristics of battery at various frequency ranges in the electrochemical impedance spectroscopy experimental study. Also the impedance spectrum affected by SoH (state of health) is discussed in the paper preliminary. Therefore, the excitation frequency selected to estimate the inner temperature is in the frequency range which is significantly influenced by temperature without the SoC and SoH. The intrinsic relationship between the phase shift and temperature is established under the chosen excitation frequency. And the magnitude of impedance related to temperature is studied in the paper. In practical applications, through obtaining the phase shift and magnitude of impedance, the inner temperature estimation could be achieved. Then the verification experiments are conduced to validate the estimate method. Finally, an estimate strategy and an on-line estimation system implementation scheme utilizing battery management system are presented to describe the engineering value.

  3. Establishment of muscle mass diagnostic standard of sarcopenia using a bioelectrical impedance analysis and epidemiological investigation of the elderly in Shanghai%上海地区老年人肌少症骨骼肌质量诊断标准建立和流行病学调查

    Institute of Scientific and Technical Information of China (English)

    陈敏; 白慧婧; 王纯; 王彦; 徐丹凤; 谢华; 易青; 李臻; 李茹

    2015-01-01

    目的 应用生物电阻抗法(BIA)建立上海地区老年人肌少症骨骼肌质量诊断标准并开展上海地区老年人肌少症患病率的调查.方法 对40例志愿者(年龄20~77岁)进行BIA和双能X线吸收仪(DEXA)检测,验证BIA测定瘦体组织的可靠性.对219例(年龄20~40岁)健康青年人(男∶女为100∶119)进行BIA检测,获得峰值肌量和老年人肌少症诊断切点.对657例≥60岁医院体检和社区老年人(男∶女为318∶339)进行BIA检测,了解上海地区老年人肌少症患病率.结果 BIA和DEXA检测瘦体组织差异无统计学意义(P=0.307).健康青年人四肢肌肉组织和身高平方的比值(ASM/身高2)男性和女性分别为(7.90±0.62)kg/m2和(6.12±0.44)kg/m2,老年人肌少症诊断标准男性和女性分别为≤6.66 kg/m2和≤5.24 kg/m2.将老年人分为3个年龄段,60~岁、70~岁和≥80岁3个年龄段男性肌少症的患病率分别为14.6%、25.0%和36.0%,女性分别为6.8%、12.6%和27.9%.老年男性整体患病率为23.6%,女性为11.8%.结论 BIA检测人体肌肉组织是可靠的,且随增龄肌少症患病率明显上升,男性高于女性.%Objective To establish diagnostic standard of sarcopenia using bioelectrical impedance analysis (BIA) and to obtain the prevalence of sarcopenia in the elderly in Shanghai.Methods 40 volunteers aged 20-77 years were enrolled and received BIA and dual-energy X-ray absorptiometry (DEXA) measurements in order to verify the reliability of BIA for measuring lean mass.219 healthy young volunteers aged 20 to 40 years with ratio of gender men:women 100:119 had BIA measurements to obtain peak muscle mass and sarcopenia diagnostic cut-off point of the elderly.657 elderly aged ≥ 60 years with ratio of gendermen:women 318:339 took BIA measurements to obtain the prevalence of sarcopenia in the elderly in Shanghai.Results No statistical difference between BIA-measured and DEXA-measured LM was observed (P =0.307).The

  4. INVESTIGATION OF CEMENT CONCRETE CONGLOMERATE SOLIDIFICATION PROCESS BY IMPEDANCE SPECTROSCOPY METHOD

    Directory of Open Access Journals (Sweden)

    S. N. Bandarenka

    2015-01-01

    Full Text Available One of the most prospective directions in preservation  and increase of service live of  road pavements is a construction of  automobile roads with cement concrete surface. Modern tendencies for provision of road construction quality presuppose a necessity to control processes of solidification and subsequent destruction of the material while forming and using cement concrete conglomerate being considered as a basic element of the road surface.  Multiyear practical experience of  automobile road operation using cement concrete pavements reveals an importance for monitoring  such processes as formation and destruction of cement concrete materials. An impedance spectroscopy method has been tried out and proposed as a tool for solution of the given problem.Experimental samples of cement concrete have been prepared for execution of tests, graded silica sand and granite chippings with particle size from 0.63 to 2.5 mm have been used as a fine aggregate in the samples. Dependencies of resistance (impedance on AC-current frequency  have been studied for samples of various nature and granulometric composition. The Gamry  G300 potentiostat has been used for measurement of complex impedance value. A spectrum analysis and calculation of equivalent circuit parameters calculation have been carried out while using EIS Spectrum Analyzer program.Comparison of impedance spectra for the prepared cement concrete samples have made it possible to reveal tendencies in changing spectrum parameters during solidification and subsequent contact with moisture in respect of every type of the sample. An equivalent electrical circuit has been developed that  characterizes physical and chemical processes which are accompanied by charge transfer in cement concrete conglomerate. The paper demonstrates a possibility to use an impedance spectroscopy for solution of a number of actual problems in the field of cement concrete technology problems. Particularly, the problems

  5. Electrothermal impedance spectroscopy as a cost efficient method for determining thermal parameters of lithium ion batteries

    DEFF Research Database (Denmark)

    Swierczynski, Maciej Jozef; Stroe, Daniel Loan; Stanciu, Tiberiu

    2017-01-01

    Current lithium-ion battery research aims in not only increasing their energy density but also power density. Emerging applications of lithium-ion batteries (hybrid electric vehicles, plug-in hybrid electric vehicles, grid support) are becoming more and more power demanding. The increasing charging...... spectroscopy method can be still improved in terms of e.g. accuracy and measurement time and it has a potential to be extended to new applications. Performed review indicates that the electrothermal impedance spectroscopy is a very promising, non-destructive, simple and especially cost-efficient method...

  6. D-bar method for electrical impedance tomography with discontinuous conductivities

    DEFF Research Database (Denmark)

    Knudsen, Kim; Lassas, Matti; Mueller, Jennifer L.;

    The effects of truncating the (approximate) scattering transform in the D-bar reconstruction method for 2-D electrical impedance tomography are studied. The method is based on Nachman s uniqueness proof [Ann. of Math. 143 (1996)] that applies to twice differentiable conductivities. However......, the reconstruction algorithm has been successfully applied to experimental data, which can be characterized as piecewise smooth conductivities. The truncation is shown to stabilize the method against measurement noise and to have a smoothing effect on the reconstructed conductivity. Thus the truncation can...... be interpreted as regularization of the D-bar method. Numerical reconstructions are presented demonstrating that features of discontinuous high contrast conductivities can be recovered using the D-bar method. Further, a new connection between Calder´on s linearization method and the D-bar method is established...

  7. A hybrid method for determination of the acoustic impedance of an unflanged cylindrical duct for multimode wave

    Science.gov (United States)

    Snakowska, Anna; Jurkiewicz, Jerzy; Gorazd, Łukasz

    2017-05-01

    The paper presents derivation of the impedance matrix based on the rigorous solution of the wave equation obtained by the Wiener-Hopf technique for a semi-infinite unflanged cylindrical duct. The impedance matrix allows, in turn, calculate the acoustic impedance along the duct and, as a special case, the radiation impedance. The analysis is carried out for a multimode incident wave accounting for modes coupling on the duct outlet not only qualitatively but also quantitatively for a selected source operating inside. The quantitative evaluation of the acoustic impedance requires setting of modes amplitudes which has been obtained applying the mode decomposition method to the far-field pressure radiation measurements and theoretical formulae for single mode directivity characteristics for an unflanged duct. Calculation of the acoustic impedance for a non-uniform distribution of the sound pressure and the sound velocity on a duct cross section requires determination of the acoustic power transmitted along/radiated from a duct. In the paper, the impedance matrix, the power, and the acoustic impedance were derived as functions of Helmholtz number and distance from the outlet.

  8. A simplified fractional order impedance model and parameter identification method for lithium-ion batteries

    Science.gov (United States)

    Yang, Qingxia; Xu, Jun; Cao, Binggang; Li, Xiuqing

    2017-01-01

    Identification of internal parameters of lithium-ion batteries is a useful tool to evaluate battery performance, and requires an effective model and algorithm. Based on the least square genetic algorithm, a simplified fractional order impedance model for lithium-ion batteries and the corresponding parameter identification method were developed. The simplified model was derived from the analysis of the electrochemical impedance spectroscopy data and the transient response of lithium-ion batteries with different states of charge. In order to identify the parameters of the model, an equivalent tracking system was established, and the method of least square genetic algorithm was applied using the time-domain test data. Experiments and computer simulations were carried out to verify the effectiveness and accuracy of the proposed model and parameter identification method. Compared with a second-order resistance-capacitance (2-RC) model and recursive least squares method, small tracing voltage fluctuations were observed. The maximum battery voltage tracing error for the proposed model and parameter identification method is within 0.5%; this demonstrates the good performance of the model and the efficiency of the least square genetic algorithm to estimate the internal parameters of lithium-ion batteries. PMID:28212405

  9. A simplified fractional order impedance model and parameter identification method for lithium-ion batteries.

    Science.gov (United States)

    Yang, Qingxia; Xu, Jun; Cao, Binggang; Li, Xiuqing

    2017-01-01

    Identification of internal parameters of lithium-ion batteries is a useful tool to evaluate battery performance, and requires an effective model and algorithm. Based on the least square genetic algorithm, a simplified fractional order impedance model for lithium-ion batteries and the corresponding parameter identification method were developed. The simplified model was derived from the analysis of the electrochemical impedance spectroscopy data and the transient response of lithium-ion batteries with different states of charge. In order to identify the parameters of the model, an equivalent tracking system was established, and the method of least square genetic algorithm was applied using the time-domain test data. Experiments and computer simulations were carried out to verify the effectiveness and accuracy of the proposed model and parameter identification method. Compared with a second-order resistance-capacitance (2-RC) model and recursive least squares method, small tracing voltage fluctuations were observed. The maximum battery voltage tracing error for the proposed model and parameter identification method is within 0.5%; this demonstrates the good performance of the model and the efficiency of the least square genetic algorithm to estimate the internal parameters of lithium-ion batteries.

  10. Bioelectrical impedance and visceral fat: a comparison with computed tomography in adults and elderly; Bioimpedancia eletrica e gordura visceral: uma comparacao com a tomografia computadorizada em adultos e idosos

    Energy Technology Data Exchange (ETDEWEB)

    Eickemberg, Michaela [Universidade Federal da Bahia (UFBA), Salvador, BA (Brazil); Roriz, Anna Karla Carneiro [Universidade Federal da Bahia (UFBA), Salvador, BA (Brazil); Fontes, Gardenia Abreu Vieira [Universidade Federal da Bahia (UFBA), Salvador, BA (Brazil); Sampaio, Lilian Ramos [Universidade Federal de Sao Paulo (Unifesp), Sao Paulo, SP (Brazil)

    2013-05-01

    Objective: To evaluate the association between electrical bioimpedance analysis (BIA) and visceral fat (VF) in adult and elderly patients. Subjects and methods: This was a cross-sectional study, with a sample of 191 subjects (52% women, 49% elderly) stratified by sex, age and body mass. Computerized tomography (VF area) and BIA (percentage of total body fat (%TBF-BIA), phase angle, reactance and resistance) data were generated. Statistical analysis was based on Pearson's Correlation Coefficient, Anova, Pearson's Chi-square, and ROC curves. Results: VF areas {>=} 130 cm{sup 2} were more prevalent among the elderly and among men. Adult females showed a stronger correlation between GV and %TBF-BIA. The other groups showed similar results and statistically significant correlations. Correlations between GV and phase angle were weak and not statistically significant. ROC Curves analyzes showed the following %TBF-BIA, which identified excess VF: for male subjects: 21.5% (adults) and 24.25% (elderly); for female subjects: 35.05% (adults) and 38.45% (elderly) with sensitivity of 78.6%, 82.1%, 83.3%, and 66.7%, and specificity of 70.6%, 62.5%, 79.1%, and 69%, respectively. Conclusion: BIA was found to have satisfactory sensitivity and specificity to predict VF; however, other devices and other techniques should be investigated to improve VF prediction. (author)

  11. Method of calculation of thin-film resistor electrode’s impedance

    Directory of Open Access Journals (Sweden)

    Spirin V. G.

    2009-11-01

    Full Text Available The physical and mathematical models of electrode impedance for the thin-film resistors of rectangular and interdigital shapes are presented in this work. The impact of electrode impedance on the manufacturing and temperature errors is estimated.

  12. MULTIRESOLUTION MOMENT METHOD BASED ON THE IMPEDANCE OPERATOR FOR THE ANALYSIS OF PLANAR MICROSTRIP STRUCTURES

    Directory of Open Access Journals (Sweden)

    NEJLA OUESLATI,

    2011-03-01

    Full Text Available This paper presents an integral equation analysis of planar microstrip circuits. In the developed approach, the Moment Method (MoM with wavelet expansion is combined to the generalized equivalent circuit (GEC to characterize microstrip structures. The interest of the (GEC method is to simplify the implementation of the moment method by the translation of an electromagnetic problem to an electric one with the use of the impedance operator. In the multiresolution moment method (MRMoM-GEC, an excitation on the plane of the circuit is used in conjunction with compactly supported wavelets trial functions. This approach generates a sparse linear system. The application of the Discrete Wavelet Transform (DWT,especially for large structures, allows a significant reduction of the unit time of central processing.

  13. Electrothermal impedance spectroscopy as a cost efficient method for determining thermal parameters of lithium ion batteries: Prospects, measurement methods and the state of knowledge

    DEFF Research Database (Denmark)

    Swierczynski, Maciej Jozef; Stroe, Daniel Loan; Stanciu, Tiberiu;

    2016-01-01

    for parametrization. Recent research initiated by Barsoukov et al. proposed electrothermal impedance spectroscopy as a novel and non-destructive method of characterizing the thermal properties of batteries by defining frequency dependent thermal impedance. Despite its usefulness, the electrothermal impedance...... spectroscopy method can be still improved in terms of e.g. accuracy and measurement time and it has a potential to be extended to new applications. Performed review indicates that the electrothermal impedance spectroscopy is a very promising, non-destructive, simple and especially cost-efficient method...... for thermal characterization of batteries. The scientific intention of this paper is to collect and systematize the state of knowledge about electrothermal impedance spectroscopy and present different measurement methods on the example of a high-power lithium battery cell and finally to discuss the prospect....

  14. Evaluation of different methods for measuring the impedance of Lithium-ion batteries during ageing

    DEFF Research Database (Denmark)

    Stroe, Daniel Loan; Swierczynski, Maciej Jozef; Stroe, Ana-Irina

    2015-01-01

    The impedance represents one of the most important performance parameters of the Lithium-ion batteries since it used for power capability calculations, battery pack and system design, cooling system design and also for state-of-health estimation. In the literature, different approaches...... are presented for measuring the impedance of Lithium-ion batteries and electrochemical impedance spectroscopy and dc current pulses are the most used ones; each of these approaches has its own advantages and drawbacks. The goal of this paper is to investigate which of the most encountered impedance measurement...... approaches is the most suitable for measuring the impedance of Lithium-ion batteries during ageing....

  15. Estimation of Metabolism Characteristics for Heat-Injured Bacteria Using Dielectrophoretic Impedance Measurement Method

    Science.gov (United States)

    Amako, Eri; Enjoji, Takaharu; Uchida, Satoshi; Tochikubo, Fumiyoshi

    Constant monitoring and immediate control of fermentation processes have been required for advanced quality preservation in food industry. In the present work, simple estimation of metabolic states for heat-injured Escherichia coli (E. coli) in a micro-cell was investigated using dielectrophoretic impedance measurement (DEPIM) method. Temporal change in the conductance between micro-gap (ΔG) was measured for various heat treatment temperatures. In addition, the dependence of enzyme activity, growth capacity and membrane situation for E. coli on heat treatment temperature was also analyzed with conventional biological methods. Consequently, a correlation between ΔG and those biological properties was obtained quantitatively. This result suggests that DEPIM method will be available for an effective monitoring technique for complex change in various biological states of microorganisms.

  16. Hybrid islanding detection method by using grid impedance estimation in parallel-inverters-based microgrid

    DEFF Research Database (Denmark)

    Ghzaiel, Walid; Jebali-Ben Ghorbal, Manel; Slama-Belkhodja, Ilhem

    2014-01-01

    This paper presents a hybrid islanding detection algorithm integrated on the distributed generation unit more close to the point of common coupling of a Microgrid based on parallel inverters where one of them is responsible to control the system. The method is based on resonance excitation under...... parameters, both resistive and inductive parts, from the injected resonance frequency determination. Finally, the inverter will disconnect the microgrid from the faulty grid and reconnect the parallel inverter system to the controllable distributed system in order to ensure high power quality. This paper...... shows that grid impedance variation detection estimation can be an efficient method for islanding detection in microgrid systems. Theoretical analysis and simulation results are presented to validate the proposed method....

  17. System-on-Chip Integration of a New Electromechanical Impedance Calculation Method for Aircraft Structure Health Monitoring

    OpenAIRE

    Daniel Medale; Sebastien Rolet; Jean Yves Fourniols; Sabeha Zedek; Christophe Escriba; Hamza Boukabache

    2012-01-01

    The work reported on this paper describes a new methodology implementation for active structural health monitoring of recent aircraft parts made from carbon-fiber-reinforced polymer. This diagnosis is based on a new embedded method that is capable of measuring the local high frequency impedance spectrum of the structure through the calculation of the electro-mechanical impedance of a piezoelectric patch pasted non-permanently onto its surface. This paper involves both the laboratory based E/M...

  18. Bioelectric modulation of macrophage polarization

    Science.gov (United States)

    Li, Chunmei; Levin, Michael; Kaplan, David L.

    2016-02-01

    Macrophages play a critical role in regulating wound healing and tissue regeneration by changing their polarization state in response to local microenvironmental stimuli. The native roles of polarized macrophages encompass biomaterials and tissue remodeling needs, yet harnessing or directing the polarization response has been largely absent as a potential strategy to exploit in regenerative medicine to date. Recent data have revealed that specific alteration of cells’ resting potential (Vmem) is a powerful tool to direct proliferation and differentiation in a number of complex tissues, such as limb regeneration, craniofacial patterning and tumorigenesis. In this study, we explored the bioelectric modulation of macrophage polarization by targeting ATP sensitive potassium channels (KATP). Glibenclamide (KATP blocker) and pinacidil (KATP opener) treatment not only affect macrophage polarization, but also influence the phenotype of prepolarized macrophages. Furthermore, modulation of cell membrane electrical properties can fine-tune macrophage plasticity. Glibenclamide decreased the secretion and gene expression of selected M1 markers, while pinacidil augmented M1 markers. More interestingly, glibencalmide promoted macrophage alternative activation by enhancing certain M2 markers during M2 polarization. These findings suggest that control of bioelectric properties of macrophages could offer a promising approach to regulate macrophage phenotype as a useful tool in regenerative medicine.

  19. Simulation method for cardiac stroke volume estimation by intracardiac electrical impedance measurement.

    Science.gov (United States)

    Barak, C; Leviatan, Y; Inbar, G F; Hoekstein, K N

    1992-09-01

    Using the electrical impedance measurement technique to investigate stroke volume estimation, three models of the ventricle were simulated. A four-electrode impedance catheter was used; two electrodes to set up an electric field in the model and the other two to measure the potential difference. A new approach, itself an application of the quasi-static case of a method used to solve electromagnetic field problems, was used to solve the electric field in the model. The behaviour of the estimation is examined with respect to the electrode configuration on the catheter and to catheter location with respect to the ventricle walls. Cardiac stroke volume estimation was found to be robust to catheter location generating a 10 per cent error for an offset of 40 per cent of the catheter from the chamber axis and rotation of 20 degrees with respect to the axis. The electrode configuration has a dominant effect on the sensitivity and accuracy of the estimation. Certain configurations gave high accuracy, whereas in others high sensitivity was found with lower accuracy. This led to the conclusion that the electrode configuration should be carefully chosen according to the desired criteria.

  20. Image reconstruction based on L1 regularization and projection methods for electrical impedance tomography.

    Science.gov (United States)

    Wang, Qi; Wang, Huaxiang; Zhang, Ronghua; Wang, Jinhai; Zheng, Yu; Cui, Ziqiang; Yang, Chengyi

    2012-10-01

    Electrical impedance tomography (EIT) is a technique for reconstructing the conductivity distribution by injecting currents at the boundary of a subject and measuring the resulting changes in voltage. Image reconstruction in EIT is a nonlinear and ill-posed inverse problem. The Tikhonov method with L(2) regularization is always used to solve the EIT problem. However, the L(2) method always smoothes the sharp changes or discontinue areas of the reconstruction. Image reconstruction using the L(1) regularization allows addressing this difficulty. In this paper, a sum of absolute values is substituted for the sum of squares used in the L(2) regularization to form the L(1) regularization, the solution is obtained by the barrier method. However, the L(1) method often involves repeatedly solving large-dimensional matrix equations, which are computationally expensive. In this paper, the projection method is combined with the L(1) regularization method to reduce the computational cost. The L(1) problem is mainly solved in the coarse subspace. This paper also discusses the strategies of choosing parameters. Both simulation and experimental results of the L(1) regularization method were compared with the L(2) regularization method, indicating that the L(1) regularization method can improve the quality of image reconstruction and tolerate a relatively high level of noise in the measured voltages. Furthermore, the projected L(1) method can also effectively reduce the computational time without affecting the quality of reconstructed images.

  1. Novel Optimization Method of Active Frequency Multiplier Utilizing Harmonic Terminating Impedances with DGS

    Directory of Open Access Journals (Sweden)

    M. Kasal

    2006-06-01

    Full Text Available A novel method for the optimization of the active frequency multiplier utilizing the harmonic terminating impedances with the defected ground structures (DGS has been developed. Furthermore, a new type of the low-pass filter with DGS for the higher harmonic suppression will be reported. Experimental conversion gains (14.52 dB for the doubler, 5.56 dB for the tripler and 0.43 dB for the quadrupler and real power-added efficiency (32.76 % for the doubler, 10.15 % for the tripler and 1.42 % for the quadrupler have been attained. To our knowledge, in the considered frequency range, these results represent the best performance reported up to date for the active frequency multipliers utilizing the low-cost BJTs.

  2. A real-time impedance based method to assess Rhodococcus equi virulence.

    Directory of Open Access Journals (Sweden)

    Aleksandra A Miranda-CasoLuengo

    Full Text Available Rhodococcus equi is a facultative intracellular pathogen of macrophages and the causative agent of foal pneumonia. R. equi virulence is usually assessed by analyzing intracellular growth in macrophages by enumeration of bacteria following cell lysis, which is time consuming and does not allow for a high throughput analysis. This paper describes the use of an impedance based real-time method to characterize proliferation of R. equi in macrophages, using virulent and attenuated strains lacking the vapA gene or virulence plasmid. Image analysis suggested that the time-dependent cell response profile (TCRP is governed by cell size and roundness as well as cytoxicity of infecting R. equi strains. The amplitude and inflection point of the resulting TCRP were dependent on the multiplicity of infection as well as virulence of the infecting strain, thus distinguishing between virulent and attenuated strains.

  3. A real-time impedance based method to assess Rhodococcus equi virulence.

    Science.gov (United States)

    Miranda-CasoLuengo, Aleksandra A; Miranda-CasoLuengo, Raúl; Lieggi, Nora T; Luo, Haixia; Simpson, Jeremy C; Meijer, Wim G

    2013-01-01

    Rhodococcus equi is a facultative intracellular pathogen of macrophages and the causative agent of foal pneumonia. R. equi virulence is usually assessed by analyzing intracellular growth in macrophages by enumeration of bacteria following cell lysis, which is time consuming and does not allow for a high throughput analysis. This paper describes the use of an impedance based real-time method to characterize proliferation of R. equi in macrophages, using virulent and attenuated strains lacking the vapA gene or virulence plasmid. Image analysis suggested that the time-dependent cell response profile (TCRP) is governed by cell size and roundness as well as cytoxicity of infecting R. equi strains. The amplitude and inflection point of the resulting TCRP were dependent on the multiplicity of infection as well as virulence of the infecting strain, thus distinguishing between virulent and attenuated strains.

  4. Density, ultrasound velocity, acoustic impedance, reflection and absorption coefficient determination of liquids via multiple reflection method.

    Science.gov (United States)

    Hoche, S; Hussein, M A; Becker, T

    2015-03-01

    The accuracy of density, reflection coefficient, and acoustic impedance determination via multiple reflection method was validated experimentally. The ternary system water-maltose-ethanol was used to execute a systematic, temperature dependent study over a wide range of densities and viscosities aiming an application as inline sensor in beverage industries. The validation results of the presented method and setup show root mean square errors of: 1.201E-3 g cm(-3) (±0.12%) density, 0.515E-3 (0.15%) reflection coefficient and 1.851E+3 kg s(-1) m(-2) (0.12%) specific acoustic impedance. The results of the diffraction corrected absorption showed an average standard deviation of only 0.12%. It was found that the absorption change shows a good correlation to concentration variations and may be useful for laboratory analysis of sufficiently pure liquids. The main part of the observed errors can be explained by the observed noise, temperature variation and the low signal resolution of 50 MHz. In particular, the poor signal-to-noise ratio of the second reflector echo was found to be a main accuracy limitation. Concerning the investigation of liquids the unstable properties of the reference material PMMA, due to hygroscopicity, were identified to be an additional, unpredictable source of uncertainty. While dimensional changes can be considered by adequate methodology, the impact of the time and temperature dependent water absorption on relevant reference properties like the buffer's sound velocity and density could not be considered and may explain part of the observed deviations.

  5. Development of microwave and impedance spectroscopy methods for in-situ nondestructive evaluation of alkali silica reaction in concrete

    Science.gov (United States)

    Heifetz, Alexander; Bakhtiari, Sasan; Lu, Juan; Aranson, Igor S.; Vinokur, Valerii M.; Bentivegna, Anthony F.

    2017-02-01

    Aging concrete degradation due to alkali silica reaction (ASR) is a challenge to sustainability of critical infrastructure, such as nuclear power plants. Currently, there is no standard, nondestructive method for detecting ASR in concrete. We report on the progress in developing electromagnetic (EM) methods, consisting of microwave and impedance spectroscopy techniques, for nondestructive detection of ASR. The microwave and impedance spectroscopy methods are complementary since they provide information about material electrical properties in GHz and Hz to KHz EM spectral bands, respectively. Preliminary studies were conducted using accelerated testing concrete prism specimens developed according to ASTM C1293 standard. Microwave and impedance spectroscopy measurements were performed on ASR specimens at the first and the second month maturity level, as well as on age-matched controls. Microwave tests consisted of reflection and transmission measurements using dielectric-loaded antennas, with the focus on X-band spectrum. Impedance measurements were performed using flexible electrode patches. Measurement results by both microwave and impedance spectroscopy methods indicate observable differences in electrical properties between reactive and non-reactive specimens. In addition, trends in measurement data obtained with the two complementary EM techniques are consistent and correlate with ASR progression in specimens.

  6. A new method for calculation of low-frequency coupling impedance

    Energy Technology Data Exchange (ETDEWEB)

    Kurennoy, S.S.; Stupakov, G.V.

    1993-05-01

    In high-energy proton accelerators and storage rings the bunch length is typically at least a few times larger than the radius of the vacuum chamber. For example, the SSC will have an rms bunch length above 6 cm and a beam-pipe radius below 2 cm. The main concern for beam stability in such a machine is the low-frequency impedance, i.e., the coupling impedance at frequencies wen below the cut-off frequency of the vacuum chamber. In the present paper we develop a new analytical approach for calculation of the low-frequency impedance of axisymmetric structures that allows us to give quick and reliable estimates of contributions to the impedance from various chamber discontinuities. Simple formulae for the longitudinal impedance of some typical discontinuities are obtained.

  7. Evaluation of Wall Boundary Conditions for Impedance Eduction Using a Dual-Source Method

    Science.gov (United States)

    Watson, W. R.; Jones, M. G.

    2012-01-01

    The accuracy of the Ingard-Myers boundary condition and a recently proposed modified Ingard-Myers boundary condition is evaluated for use in impedance eduction under the assumption of uniform mean flow. The evaluation is performed at three centerline Mach numbers, using data acquired in a grazing flow impedance tube, using both upstream and downstream propagating sound sources, and on a database of test liners for which the expected behavior of the impedance spectra is known. The test liners are a hard-wall insert consisting of 12.6 mm thick aluminum, a linear liner without a facesheet consisting of a number of small diameter but long cylindrical channels embedded in a ceramic material, and two conventional nonlinear liners consisting of a perforated facesheet bonded to a honeycomb core. The study is restricted to a frequency range for which only plane waves are cut on in the hard-wall sections of the flow impedance tube. The metrics used to evaluate each boundary condition are 1) how well it educes the same impedance for upstream and downstream propagating sources, and 2) how well it predicts the expected behavior of the impedance spectra over the Mach number range. The primary conclusions of the study are that the same impedance is educed for upstream and downstream propagating sources except at the highest Mach number, that an effective impedance based on both the upstream and downstream measurements is more accurate than an impedance based on the upstream or downstream data alone, and that the Ingard-Myers boundary condition with an effective impedance produces results similar to that achieved with the modified Ingard-Myers boundary condition.

  8. Electrical impedance of acupuncture meridians: the relevance of subcutaneous collagenous bands.

    Directory of Open Access Journals (Sweden)

    Andrew C Ahn

    Full Text Available BACKGROUND: The scientific basis for acupuncture meridians is unknown. Past studies have suggested that acupuncture meridians are physiologically characterized by low electrical impedance and anatomically associated with connective tissue planes. We are interested in seeing whether acupuncture meridians are associated with lower electrical impedance and whether ultrasound-derived measures--specifically echogenic collagenous bands--can account for these impedance differences. METHODS/RESULTS: In 28 healthy subjects, we assessed electrical impedance of skin and underlying subcutaneous connective tissue using a four needle-electrode approach. The impedances were obtained at 10 kHz and 100 kHz frequencies and at three body sites - upper arm (Large Intestine meridian, thigh (Liver, and lower leg (Bladder. Meridian locations were determined by acupuncturists. Ultrasound images were obtained to characterize the anatomical features at each measured site. We found significantly reduced electrical impedance at the Large Intestine meridian compared to adjacent control for both frequencies. No significant decrease in impedance was found at the Liver or Bladder meridian. Greater subcutaneous echogenic densities were significantly associated with reduced impedances in both within-site (meridian vs. adjacent control and between-site (arm vs. thigh vs. lower leg analyses. This relationship remained significant in multivariable analyses which also accounted for gender, needle penetration depth, subcutaneous layer thickness, and other ultrasound-derived measures. CONCLUSION/SIGNIFICANCE: Collagenous bands, represented by increased ultrasound echogenicity, are significantly associated with lower electrical impedance and may account for reduced impedances previously reported at acupuncture meridians. This finding may provide important insights into the nature of acupuncture meridians and the relevance of collagen in bioelectrical measurements.

  9. Linearized image reconstruction method for ultrasound modulated electrical impedance tomography based on power density distribution

    Science.gov (United States)

    Song, Xizi; Xu, Yanbin; Dong, Feng

    2017-04-01

    Electrical resistance tomography (ERT) is a promising measurement technique with important industrial and clinical applications. However, with limited effective measurements, it suffers from poor spatial resolution due to the ill-posedness of the inverse problem. Recently, there has been an increasing research interest in hybrid imaging techniques, utilizing couplings of physical modalities, because these techniques obtain much more effective measurement information and promise high resolution. Ultrasound modulated electrical impedance tomography (UMEIT) is one of the newly developed hybrid imaging techniques, which combines electric and acoustic modalities. A linearized image reconstruction method based on power density is proposed for UMEIT. The interior data, power density distribution, is adopted to reconstruct the conductivity distribution with the proposed image reconstruction method. At the same time, relating the power density change to the change in conductivity, the Jacobian matrix is employed to make the nonlinear problem into a linear one. The analytic formulation of this Jacobian matrix is derived and its effectiveness is also verified. In addition, different excitation patterns are tested and analyzed, and opposite excitation provides the best performance with the proposed method. Also, multiple power density distributions are combined to implement image reconstruction. Finally, image reconstruction is implemented with the linear back-projection (LBP) algorithm. Compared with ERT, with the proposed image reconstruction method, UMEIT can produce reconstructed images with higher quality and better quantitative evaluation results.

  10. Relevance of a new impedance matching, or subtrap, method for the reduction of pain during hyperthermia.

    Science.gov (United States)

    Murata, T; Akagi, K; Ostapenko, V V; Isoda, H; Nagata, K; Nasu, R; Shiga, T; Tanaka, Y; Yamamoto, I

    1998-01-01

    Capacitive heating is widely used in hyperthermic treatment of human malignancies. However, the pain on the body surface or thermoesthesia in the subcutaneous fatty layer may prevent an elevation of temperature in the tumors. Impedance matching is improved by a subtrap method entailing the application of two copper plates (10 x 850 x 0.06 mm) as a subtrap circuit to each of two capacitive electrodes. In a clinical trial the Tmax, Tave, Tmin for the subtrap method were all higher in comparison with those for the conventional technique (42.5 +/- 0.7 degrees C, 41.9 +/- 1.0 degrees C, 41.3 +/- 1.1 degrees C vs. 41.1 +/- 1.5 degrees C, 40.6 +/- 1.3 degrees C, 40.0 +/- 1.3 degrees C). Although the maximal radiofrequency (RF) power applied to patients was higher with the subtrap method (875 +/- 189 W vs. 763 +/- 200 W), the incidence of surface pain was reduced dramatically. It is concluded that the subtrap method substantially improves the RF capacitive heating of deep-seated tumors.

  11. First characterization of a new method for numerically solving the Dirichlet problem of the two-dimensional Electrical Impedance Equation

    CERN Document Server

    T., M P Ramirez; Hernandez-Becerril, R A

    2012-01-01

    Based upon elements of the modern Pseudoanalytic Function Theory, we analyse a new method for numerically approaching the solution of the Dirichlet boundary value problem, corresponding to the two-dimensional Electrical Impedance Equation. The analysis is performed by interpolating piecewise separable-variables conductivity functions, that are eventually used in the numerical calculations in order to obtain finite sets of orthonormal functions, whose linear combinations succeed to approach the imposed boundary conditions. To warrant the effectiveness of the numerical method, we study six different examples of conductivity. The boundary condition for every case is selected considering one exact solution of the Electrical Impedance Equation. The work intends to discuss the contributions of these results into the field of the Electrical Impedance Tomography.

  12. Lactate threshold by muscle electrical impedance in professional rowers

    Science.gov (United States)

    Jotta, B.; Coutinho, A. B. B.; Pino, A. V.; Souza, M. N.

    2017-04-01

    Lactate threshold (LT) is one of the physiological parameters usually used in rowing sport training prescription because it indicates the transitions from aerobic to anaerobic metabolism. Assessment of LT is classically based on a series of values of blood lactate concentrations obtained during progressive exercise tests and thus has an invasive aspect. The feasibility of noninvasive LT estimative through bioelectrical impedance spectroscopy (BIS) data collected in thigh muscles during rowing ergometer exercise tests was investigated. Nineteen professional rowers, age 19 (mean) ± 4.8 (standard deviation) yr, height 187.3 ± 6.6 cm, body mass 83 ± 7.7 kg, and training experience of 7 ± 4 yr, were evaluated in a rowing ergometer progressive test with paired measures of blood lactate concentration and BIS in thigh muscles. Bioelectrical impedance data were obtained by using a bipolar method of spectroscopy based on the current response to a voltage step. An electrical model was used to interpret BIS data and to derive parameters that were investigated to estimate LT noninvasively. From the serial blood lactate measurements, LT was also determined through Dmax method (LTDmax). The zero crossing of the second derivative of kinetic of the capacitance electrode (Ce), one of the BIS parameters, was used to estimate LT. The agreement between the LT estimates through BIS (LTBIS) and through Dmax method (LTDmax) was evaluated using Bland-Altman plots, leading to a mean difference between the estimates of just 0.07 W and a Pearson correlation coefficient r = 0.85. This result supports the utilization of the proposed method based on BIS parameters for estimating noninvasively the lactate threshold in rowing.

  13. NUMERICAL SIMULATION OF ELECTRICAL IMPEDANCE TOMOGRAPHY PROBLEM AND STUDY OF APPROACH BASED ON FINITE VOLUME METHOD

    Directory of Open Access Journals (Sweden)

    Ye. S. Sherina

    2014-01-01

    Full Text Available This research has been aimed to carry out a study of peculiarities that arise in a numerical simulation of the electrical impedance tomography (EIT problem. Static EIT image reconstruction is sensitive to a measurement noise and approximation error. A special consideration has been given to reducing of the approximation error, which originates from numerical implementation drawbacks. This paper presents in detail two numerical approaches for solving EIT forward problem. The finite volume method (FVM on unstructured triangular mesh is introduced. In order to compare this approach, the finite element (FEM based forward solver was implemented, which has gained the most popularity among researchers. The calculated potential distribution with the assumed initial conductivity distribution has been compared to the analytical solution of a test Neumann boundary problem and to the results of problem simulation by means of ANSYS FLUENT commercial software. Two approaches to linearized EIT image reconstruction are discussed. Reconstruction of the conductivity distribution is an ill-posed problem, typically requiring a large amount of computation and resolved by minimization techniques. The objective function to be minimized is constructed of measured voltage and calculated boundary voltage on the electrodes. A classical modified Newton type iterative method and the stochastic differential evolution method are employed. A software package has been developed for the problem under investigation. Numerical tests were conducted on simulated data. The obtained results could be helpful to researches tackling the hardware and software issues for medical applications of EIT.

  14. Use of low-frequency electrical impedance measurements to determine phospholipid content in amniotic fluid

    Science.gov (United States)

    DeLuca, F.; Cametti, C.; Zimatore, G.; Maraviglia, B.; Pachi', A.

    1996-09-01

    In this report we propose a new method for an in vitro test of the foetal lung maturity based on the measurement of the electrical conductivity of the overall amniotic fluid obtained from transabdominal amniocentesis, since this quantity can be linked to a first approximation in a very simple way to the phospholipid content. We have carried out measurements of 85 different samples of amniotic fluid as a function of gestation weeks and we have observed a pronounced change of the electrical conductivity that reflects the increase in the phospholipid concentration occurring at the end of normal pregnancies. The method could be further developed to obtain similar information on in vivo experiments by means of bioelectric impedance tomography, taking advantage of the frequency dependence of the tissue electrical impedance.

  15. Fundamental impedance identification method for grid-connected voltage source inverters

    DEFF Research Database (Denmark)

    Sun, Xiaofeng; Chen, J.; Guerrero, Josep M.

    2014-01-01

    Considering the importance of line fundamental impedance from the inverter to the point of common coupling (PCC) in microgrids, this study analyses the influence of fundamental impedance on system stability. Line fundamental impedance values not only apply to decoupled droop control, which can...... realise accurate control between active and reactive power, but also regulate the droop coefficient to eliminate system circulation, realise power sharing and improve system stability when a multi-distributed generation system operates in parallel. Moreover, the PCC can sense grid fault on the basis...

  16. Impedance cardiography – Old method, new opportunities. Part II. Testing of cardiovascular response to various factors of work environment

    Directory of Open Access Journals (Sweden)

    Jadwiga Siedlecka

    2015-02-01

    Full Text Available Impedance cardiography seems to be a very good, although underappreciated diagnostic method. What may distinguish it from among the many research methods is the fact that it enables non-invasive monitoring of cardiac output, stroke volume and systemic vascular resistance. Holter recording of the hemodynamic parameters makes it possible to study them not only in stationary (hospital, outpatient clinic conditions, but also during household or professional activities, e.g., during road vehicle driving. Assessment of the trends of changes in the circulatory system of the employee at work makes it possible to judge whether the type of work performed by the worker is well tolerated – whether it is not too hard or too stressful. This is important, therefore, impedance cardiography can be extensively used in occupational medicine. Provision of preventive care to workers according to current standards requires, on the one hand, the use of the latest diagnostic methods while, on the other hand, the methods must be inexpensive, because otherwise the employer would not be able or willing to pay the associated costs. Impedance cardiography meets those criteria; however, few data is available in literature worldwide on the use of this method in the research on the impact of occupational work on cardiovascular responses of the employees. This work reports the use of impedance cardiography in studies on the various aspects of work environment.

  17. Characterization of the Minimum Effective Layer of Thermal Insulation Material Tow-plaster from the Method of Thermal Impedance

    Directory of Open Access Journals (Sweden)

    M.S. Ould Brahim

    2011-04-01

    Full Text Available Our objective in this study is to determine the effective thermal insulating layer of a composite towplaster. The characterization of thermal insulating material is proposed from the study of the thermal impedance in dynamic two-dimensional frequency. Thermo physical properties of the material tow-plaster are determined from the study of the thermal impedance. Nyquist representations have introduced an interpretation of certain phenomena of heat transfer from the series and shunt resistors. The overall coefficient of heat exchange is determined from the Bode plots. A method for determining the thermal conductivity is proposed.

  18. On the impedance of galvanic cells XXVI. Application of the complex plane method in the case of mixed currents

    NARCIS (Netherlands)

    Dekker, B.G.; Sluyters-Rehbach, M.; Sluyters, J.H.

    1969-01-01

    The applicability of the complex plane method for the evaluation of the impedance parameters in the case of two simultaneously proceeding electrode reactions is discussed. It is shown that the possibility of the evaluation depends strongly on the values of the irreversibility quotients of both react

  19. Application of the Method of Auxiliary Sources for the Analysis of Plane-Wave Scattering by Impedance Spheres

    DEFF Research Database (Denmark)

    Karamehmedovic, Mirza; Breinbjerg, Olav

    2002-01-01

    The Method of Auxiliary Sources (MAS) is applied to 3D scattering problems involving spherical impedance scatterers. The MAS results are compared with the reference spherical wave expansion (SWE) solution. It is demonstrated that good agreement is achieved between the MAS and SWE results....

  20. Acoustic Radiation Impedances And Impulse Responses For Elliptical Cylinders Using Internal Source Density And Singular Value Decomposition Methods

    Science.gov (United States)

    Stepanishen, P. R.; Ramakrishna, S.

    1994-09-01

    A new internal source distribution method is combined with the singular value decomposition method to determine the acoustic impedance and associated impulse response for an infinite cylinder with a plane of symmetry and a normal velocity with a specified circumferential variation. An internal linear distribution of unknown monopole and/or dipole line sources along the plane of symmetry is determined to match the specified harmonic normal velocity on the surface in a least mean square error sense. After the discretization of the source distributions, the subsequent solution of a set or sets of linear algebraic equations for the internal source distributions is obtained using the singular value decomposition method. Line integrals for the associated surface pressure, the acoustic impedance and the corresponding impulse response are then simply evaluated by quadrature methods. Numerical results for the acoustic impedances and associated impulse responses are presented for circular cylinders vibrating with various natural in vacuo modal shapes. Numerical results for acoustic impedances and associated impulse responses for elliptical cylinders vibrating with various natural in vacuo modal shapes are then presented, and their characteristics are discussed and compared to the corresponding results for circular cylinders.

  1. An electrochemical study of corrosion protection by primer-topcoat systems on 4130 steel with ac impedance and dc methods

    Science.gov (United States)

    Mendrek, M. J.; Higgins, R. H.; Danford, M. D.

    1988-01-01

    To investigate metal surface corrosion and the breakdown of metal protective coatings, the ac impedance method is applied to six systems of primer coated and primer topcoated 4130 steel. Two primers were used: a zinc-rich epoxy primer and a red lead oxide epoxy primer. The epoxy-polyamine topcoat was used in four of the systems. The EG and G-PARC Model 368 ac impedance measurement system, along with dc measurements with the same system using the polarization resistance method, were used to monitor changing properties of coated 4230 steel disks immersed in 3.5 percent NaCl solutions buffered at pH 5.4 over periods of 40 to 60 days. The corrosion system can be represented by an electronic analog called an equivalent circuit consisting of resistors and capacitors in specific arrangements. This equivalent circuit parallels the impedance behavior of the corrosion system during a frequency scan. Values for the resistors and capacitors, that can be assigned in the equivalent circuit following a least-squares analysis of the data, describe changes that occur on the corroding metal surface and in the protective coatings. Two equivalent circuits have been determined that predict the correct Bode phase and magnitude of the experimental sample at different immersion times. The dc corrosion current density data are related to equivalent circuit element parameters. Methods for determining corrosion rate with ac impedance parameters are verified by the dc method.

  2. System-on-chip integration of a new electromechanical impedance calculation method for aircraft structure health monitoring.

    Science.gov (United States)

    Boukabache, Hamza; Escriba, Christophe; Zedek, Sabeha; Medale, Daniel; Rolet, Sebastien; Fourniols, Jean Yves

    2012-10-11

    The work reported on this paper describes a new methodology implementation for active structural health monitoring of recent aircraft parts made from carbon-fiber-reinforced polymer. This diagnosis is based on a new embedded method that is capable of measuring the local high frequency impedance spectrum of the structure through the calculation of the electro-mechanical impedance of a piezoelectric patch pasted non-permanently onto its surface. This paper involves both the laboratory based E/M impedance method development, its implementation into a CPU with limited resources as well as a comparison with experimental testing data needed to demonstrate the feasibility of flaw detection on composite materials and answer the question of the method reliability. The different development steps are presented and the integration issues are discussed. Furthermore, we present the unique advantages that the reconfigurable electronics through System-on-Chip (SoC) technology brings to the system scaling and flexibility. At the end of this article, we demonstrate the capability of a basic network of sensors mounted onto a real composite aircraft part specimen to capture its local impedance spectrum signature and to diagnosis different delamination sizes using a comparison with a baseline.

  3. System-on-Chip Integration of a New Electromechanical Impedance Calculation Method for Aircraft Structure Health Monitoring

    Science.gov (United States)

    Boukabache, Hamza; Escriba, Christophe; Zedek, Sabeha; Medale, Daniel; Rolet, Sebastien; Fourniols, Jean Yves

    2012-01-01

    The work reported on this paper describes a new methodology implementation for active structural health monitoring of recent aircraft parts made from carbon-fiber-reinforced polymer. This diagnosis is based on a new embedded method that is capable of measuring the local high frequency impedance spectrum of the structure through the calculation of the electro-mechanical impedance of a piezoelectric patch pasted non-permanently onto its surface. This paper involves both the laboratory based E/M impedance method development, its implementation into a CPU with limited resources as well as a comparison with experimental testing data needed to demonstrate the feasibility of flaw detection on composite materials and answer the question of the method reliability. The different development steps are presented and the integration issues are discussed. Furthermore, we present the unique advantages that the reconfigurable electronics through System-on-Chip (SoC) technology brings to the system scaling and flexibility. At the end of this article, we demonstrate the capability of a basic network of sensors mounted onto a real composite aircraft part specimen to capture its local impedance spectrum signature and to diagnosis different delamination sizes using a comparison with a baseline. PMID:23202013

  4. System-on-Chip Integration of a New Electromechanical Impedance Calculation Method for Aircraft Structure Health Monitoring

    Directory of Open Access Journals (Sweden)

    Daniel Medale

    2012-10-01

    Full Text Available The work reported on this paper describes a new methodology implementation for active structural health monitoring of recent aircraft parts made from carbon-fiber-reinforced polymer. This diagnosis is based on a new embedded method that is capable of measuring the local high frequency impedance spectrum of the structure through the calculation of the electro-mechanical impedance of a piezoelectric patch pasted non-permanently onto its surface. This paper involves both the laboratory based E/M impedance method development, its implementation into a CPU with limited resources as well as a comparison with experimental testing data needed to demonstrate the feasibility of flaw detection on composite materials and answer the question of the method reliability. The different development steps are presented and the integration issues are discussed. Furthermore, we present the unique advantages that the reconfigurable electronics through System-on-Chip (SoC technology brings to the system scaling and flexibility. At the end of this article, we demonstrate the capability of a basic network of sensors mounted onto a real composite aircraft part specimen to capture its local impedance spectrum signature and to diagnosis different delamination sizes using a comparison with a baseline.

  5. A Planar Interdigital Sensor for Bio-impedance Measurement: Theoretical analysis, Optimization and Simulation

    Directory of Open Access Journals (Sweden)

    Thanh-Tuan Ngo

    2014-04-01

    Full Text Available This paper proposes the design of a biosensor to characterize the dielectric and conductive properties of biological materials (for example blood or water by impedance spectroscopy. Particularly, its design optimized the geometric structure interdigitated electrodes. This optimization allows extending the frequency range of measurement by reducing the polarization effect. Polarization effect is manifested by an interface capability (or double layer from interaction between ions and molecules in the boundary between the surface of the electrolyte and the electrodes, it increases the measurement error at low frequencies. This paper recommends also a novel method to determine the parameters (relative permittivity, thickness and capacitance per unit area of the double layer (DL at the contact surface of the electrode with the solution. CoventorWare software was utilized to modelize of interdigital sensor structure in three dimensions (3D to verify the analytical results and evaluate the influence of geometrical parameters and the dielectric properties of the medium on bioelectrical impedance.

  6. Applicability of impedance measuring method to the detection of irradiation treatment of potatoes

    Energy Technology Data Exchange (ETDEWEB)

    Hayashi, Toru; Todoriki, Setsuko; Otobe, Kazunori; Sugiyama, Junnichi (National Food Research Inst., Tsukuba, Ibaraki (Japan))

    1993-05-01

    The incubation condition of potato tubers prior to impedance measurement greatly influenced the reliability of detection of irradiated potatoes; the impedance ratio at 5 kHz to 50 kHz (Z[sub 5k]/Z[sub 50k]) determined at 22degC at an apical region of tuber which was pre-incubated at 22degC for 3 days or longer resulted in the best detection of radiation treatment of potatoes. The impedance ratio was dependent upon dose applied to potato tubers. Potatoes irradiated at 100 Gy could be distinguished from unirradiated potatoes for 10 cultivars of potatoes. The impedance ratio of potatoes irradiated at the same dose was little influenced by the planting locality if the cultivar was the same, although the ratio varied with potato cultivars. These results indicate that irradiated potatoes can be detected if the potato cultivar is known. Potatoes 'Danshaku' commercially irradiated at the Shihiro Potato Irradiation Center could be differentiated from unirradiated 'Danshaku' at different planting localities; the impedance ratio was lower than 2.75 for the unirradiated potatoes and higher than 2.75 for the irradiated ones. (author).

  7. A Method of Function Space for Vertical Impedance Function of a Circular Rigid Foundation on a Transversely Isotropic Ground

    Directory of Open Access Journals (Sweden)

    Morteza Eskandari-Ghadi

    2014-06-01

    Full Text Available This paper is concerned with investigation of vertical impedance function of a surface rigid circular foundation resting on a semi-infinite transversely isotropic alluvium. To this end, the equations of motion in cylindrical coordinate system, which because of axissymmetry are two coupled equations, are converted into one partial differential equation using a method of potential function. The governing partial differential equation for the potential function is solved via implementing Hankel integral transforms in radial direction. The vertical and radial components of displacement vector are determined with the use of transformed displacement-potential function relationships. The mixed boundary conditions at the surface are satisfied by specifying the traction between the rigid foundation and the underneath alluvium in a special function space introduced in this paper, where the vertical displacements are forced to satisfy the rigid boundary condition. Through exercising these restraints, the normal traction and then the vertical impedance function are obtained. The results are then compared with the existing results in the literature for the simpler case of isotropic half-space, which shows an excellent agreement. Eventually, the impedance functions are presented in terms of dimensionless frequency for different materials. The method presented here may be used to obtain the impedance function in any other direction as well as in buried footing in layered media.

  8. Development of a method to estimate the lifespan of proton exchange membrane fuel cell using electrochemical impedance spectroscopy

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Ju-hyung; Lee, Jong-Hak; Choi, Woojin [Department of Electrical Engineering, Soongsil University, 1-1 Sangdo-dong, Dongjak-gu, Seoul 156-743 (Korea); Park, Kyung-Won [Department of Chemical/Environmental Engineering, Soongsil University, 1-1 Sangdo-dong, Dongjak-gu, Seoul 156-743 (Korea); Sun, Hee-Young [Samsung Advanced Institute of Technology, Mt. 14-1, Nongseo-dong, Giheung-gu, Yongin-si, Gyeonggi-do 446-712 (Korea); Oh, Jae-Hyuk [Samsung Electronics, 416 Maetan-dong, Youngtong-gu, Suwon-si, Gyeonggi-do 443-370 (Korea)

    2010-09-15

    This paper proposes a new method for estimating the state and lifespan of fuel cells in operation by fuel cell equivalent impedance modeling by electrochemical impedance spectroscopy (EIS) and observing degradation. The performance change of fuel cells takes place in the form of changes in each parameter value comprising an equivalent AC impedance circuit; monitoring such changes allows for the prediction of the state and lifespan of a fuel cell. In the experiments, the AC impedance of high-temperature proton exchange membrane (PEM) fuel cells was measured at constant time intervals during their continuous operation for over 2200 h. The expression for the lifespan of a fuel cell was deduced by curve fitting the changes in each parameter to a polynomial. Electric double layer capacitance and charge transfer resistance, which show the reduction reaction of the cathode, were used as major parameters for judging the degradation; a method of using time constants is proposed to more accurately estimate the degree of degradation. In addition, an algorithm that can evaluate the soundness and lifespan of a fuel cell is proposed; it compares the measured time constant of the fuel cell being tested with that of average lifespan fuel cell. (author)

  9. A Review of Electrical Impedance Spectrometry Methods for Parametric Estimation of Physiologic Fluid Volumes

    Science.gov (United States)

    Dewberry, B.

    2000-01-01

    Electrical impedance spectrometry involves measurement of the complex resistance of a load at multiple frequencies. With this information in the form of impedance magnitude and phase, or resistance and reactance, basic structure or function of the load can be estimated. The "load" targeted for measurement and estimation in this study consisted of the water-bearing tissues of the human calf. It was proposed and verified that by measuring the electrical impedance of the human calf and fitting this data to a model of fluid compartments, the lumped-model volume of intracellular and extracellular spaces could be estimated, By performing this estimation over time, the volume dynamics during application of stimuli which affect the direction of gravity can be viewed. The resulting data can form a basis for further modeling and verification of cardiovascular and compartmental modeling of fluid reactions to microgravity as well as countermeasures to the headward shift of fluid during head-down tilt or spaceflight.

  10. Analogies between the measurement of acoustic impedance via the reaction on the source method and the automatic microwave vector network analyzer technique

    Science.gov (United States)

    McLean, James; Sutton, Robert; Post, John

    2003-10-01

    One useful method of acoustic impedance measurement involves the measurement of the electrical impedance ``looking into'' the electrical port of a reciprocal electroacoustic transducer. This reaction on the source method greatly facilitates the measurement of acoustic impedance by borrowing highly refined techniques to measure electrical impedance. It is also well suited for in situ acoustic impedance measurements. In order to accurately determine acoustic impedance from the measured electrical impedance, the characteristics of the transducer must be accurately known, i.e., the characteristics of the transducer must be ``removed'' completely from the data. The measurement of acoustic impedance via the measurement of the reaction on the source is analogous to modern microwave measurements made with an automatic vector network analyzer. The action of the analyzer is described as de-embedding the desired data (such as acoustic impedance) from the raw data. Such measurements are fundamentally substitution measurements in that the transducer's characteristics are determined by measuring a set of reference standards. The reaction on the source method is extended to take advantage of improvements in microwave measurement techniques which allow calibration via imperfect standard loads. This removes one of the principal weaknesses of the method in that the requirement of high-quality reference standards is relaxed.

  11. First Characterization of a New Method for Numerically Solving the Dirichlet Problem of the Two-Dimensional Electrical Impedance Equation

    OpenAIRE

    Marco Pedro Ramirez-Tachiquin; Cesar Marco Antonio Robles Gonzalez; Rogelio Adrian Hernandez-Becerril; Ariana Guadalupe Bucio Ramirez

    2013-01-01

    Based upon the elements of the modern pseudoanalytic function theory, we analyze a new method for numerically solving the forward Dirichlet boundary value problem corresponding to the two-dimensional electrical impedance equation. The analysis is performed by introducing interpolating piecewise separable-variables conductivity functions in the unit circle. To warrant the effectiveness of the posed method, we consider several examples of conductivity functions, whose boundary condi...

  12. A More Accurate and Efficient Technique Developed for Using Computational Methods to Obtain Helical Traveling-Wave Tube Interaction Impedance

    Science.gov (United States)

    Kory, Carol L.

    1999-01-01

    The phenomenal growth of commercial communications has created a great demand for traveling-wave tube (TWT) amplifiers. Although the helix slow-wave circuit remains the mainstay of the TWT industry because of its exceptionally wide bandwidth, until recently it has been impossible to accurately analyze a helical TWT using its exact dimensions because of the complexity of its geometrical structure. For the first time, an accurate three-dimensional helical model was developed that allows accurate prediction of TWT cold-test characteristics including operating frequency, interaction impedance, and attenuation. This computational model, which was developed at the NASA Lewis Research Center, allows TWT designers to obtain a more accurate value of interaction impedance than is possible using experimental methods. Obtaining helical slow-wave circuit interaction impedance is an important part of the design process for a TWT because it is related to the gain and efficiency of the tube. This impedance cannot be measured directly; thus, conventional methods involve perturbing a helical circuit with a cylindrical dielectric rod placed on the central axis of the circuit and obtaining the difference in resonant frequency between the perturbed and unperturbed circuits. A mathematical relationship has been derived between this frequency difference and the interaction impedance (ref. 1). However, because of the complex configuration of the helical circuit, deriving this relationship involves several approximations. In addition, this experimental procedure is time-consuming and expensive, but until recently it was widely accepted as the most accurate means of determining interaction impedance. The advent of an accurate three-dimensional helical circuit model (ref. 2) made it possible for Lewis researchers to fully investigate standard approximations made in deriving the relationship between measured perturbation data and interaction impedance. The most prominent approximations made

  13. Estimation of fatigue evolution of aluminum alloy plated with electroless NI–CO–P by using electromagnetic impedance method

    Energy Technology Data Exchange (ETDEWEB)

    Kinoshita, Katsuyuki

    2015-02-01

    We have developed a method for detecting fatigue in aluminum alloys that is based on a applying a ferromagnetic electroless Ni–Co–P plating and then using an electromagnetic impedance (EMI) method to determine its permeability properties by measuring the high-frequency AC impedance of a coil sensor in the presence of a static magnetic field. The results obtained confirmed that this method can estimate the fatigue evolution of a specimen until the point at which the cumulative strain becomes saturated by using measurements obtained by the EMI method under tensile deformation and FEM analysis results. - Highlights: • Plating aluminum alloy with Ni–Co–P film increases its fatigue strength by 13−16%. • The tensile direction is the stress induced “hard axis” of the Ni–Co–P plating. • In-plane permeability determines the coil impedance for out-of-plane excitation. • This method can measure fatigue up to saturation of the substrate's residual strain.

  14. Method for Flow Measurement in Microfluidic Channels Based on Electrical Impedance Spectroscopy

    CERN Document Server

    Arjmandi, Nima; Van Roy, Willem; Lagae, Liesbet; Borghs, Gustaaf; 10.1007/s10404-011-0843-0

    2012-01-01

    We have developed and characterized two novel micro flow sensors based on measuring the electrical impedance of the interface between the flowing liquid and metallic electrodes embedded on the channel walls. These flow sensors are very simple to fabricate and use, are extremely compact and can easily be integrated into most microfluidic systems. One of these devices is a micropore with two tantalum/platinum electrodes on its edges; the other is a micro channel with two tantalum /platinum electrodes placed perpendicular to the channel on its walls. In both sensors the flow rate is measured via the electrical impedance between the two metallic electrodes, which is the impedance of two metal-liquid junctions in series. The dependency of the metal-liquid junction impedance on the flow rate of the liquid has been studied. The effects of different parameters on the sensor's outputs and its noise behavior are investigated. Design guidelines are extracted and applied to achieve highly sensitive micro flow sensors wit...

  15. Method to measure autonomic control of cardiac function using time interval parameters from impedance cardiography

    NARCIS (Netherlands)

    Meijer, J.H.; Boesveldt, S.; Elbertse, E.; Berendse, H.W.

    2008-01-01

    The time difference between the electrocardiogram and impedance cardiogram can be considered as a measure for the time delay between the electrical and mechanical activities of the heart. This time interval, characterized by the pre-ejection period (PEP), is related to the sympathetic autonomous ner

  16. Advantages of Nanosensors in the Development of Interfaces for Bioelectric Prostheses

    Directory of Open Access Journals (Sweden)

    Avdeeva Diana

    2016-01-01

    Full Text Available The present research aims to explore the bioelectric activity of muscles using a high-resolution electromyograph and to analyze the prospects of the electromyograph to develop bioelectric patterns for the prosthesis control method based on the data recognition system. The activity of the healthy forearm muscles was investigated during the cyclic activity of fingers in different modes. In addition, the impact of filters on the quality and informativity of myoelectric signals, as well as on the development of bioelectric activity patterns was analyzed. The virtually developed bandpass filters were utilized as experimental filters. The filter impact analysis included the comparison of the signal recorded in the frequency band from 0 to 10000 Hz with the signal filtered in the frequency band from 20 to 500 Hz. The research revealed the advantages of a high-resolution electromyogram for the pattern recognition-based myocontrol.

  17. The inverse problem of bioelectricity: an evaluation

    NARCIS (Netherlands)

    Oosterom, A. van

    2012-01-01

    This invited paper presents a personal view on the current status of the solution to the inverse problem of bioelectricity. Its focus lies on applications in the field of electrocardiography. The topic discussed is also relevant in other medical domains, such as electroencephalography, electroneurog

  18. A New Method to Calculate the Degree of Electromagnetic Impedance Matching in One-Layer Microwave Absorbers

    Institute of Scientific and Technical Information of China (English)

    MA Zhi; CAO Chen-Tao; LIU Qing-Fang; WANG Jian-Bo

    2012-01-01

    A delta-function method is proposed to quantitatively evaluate the electromagnetic impedance matching degree.Measured electromagnetic parameters of α-Fe/Fe3B/V2O3 nanocomposites are applied to calculate the matching degree by the method.Compared with reflection loss and quarter-wave principle theory,the method accurately reveals the intrinsic mechanism of microwave transmission and reflection properties.A possible honeycomb structure with promising high-performance microwave absorption,devised according to the method,is also proposed.

  19. Wakefields and coupling impedances

    Energy Technology Data Exchange (ETDEWEB)

    Kurennoy, S. (Superconducting Super Collider Laboratory, 2550 Beckleymeade Ave., Dallas, Texas 75237 (United States))

    1995-02-01

    After a short introduction of the wake potentials and coupling impedances, a few new results in impedance calculations are discussed. The first example is a new analytical method for calculating impedances of axisymmetric structures in the low frequency range, below the cutoff frequency of the vacuum chamber. The second example demonstrates that even very small discontinuities on a smooth waveguide can result in appearance of trapped modes, with frequencies slightly below the waveguide cutoff frequency. The high-frequency (above the cutoff) behavior of the coupling impedance of many small discontinuities is discussed in the third example. [copyright] 1995 [ital American] [ital Institute] [ital of] [ital Physics

  20. Wakefields and coupling impedances

    Science.gov (United States)

    Kurennoy, Sergey

    1995-02-01

    After a short introduction of the wake potentials and coupling impedances, a few new results in impedance calculations are discussed. The first example is a new analytical method for calculating impedances of axisymmetric structures in the low frequency range, below the cutoff frequency of the vacuum chamber. The second example demonstrates that even very small discontinuities on a smooth waveguide can result in appearance of trapped modes, with frequencies slightly below the waveguide cutoff frequency. The high-frequency (above the cutoff) behavior of the coupling impedance of many small discontinuities is discussed in the third example.

  1. Analysis of dye-sensitized solar cells with current collecting electrodes using electrochemical impedance spectroscopy, with a finite element method

    Science.gov (United States)

    Shitanda, Isao; Inoue, Kazuya; Hoshi, Yoshinao; Itagaki, Masayuki

    2014-02-01

    The internal resistances of dye-sensitized solar cells (DSCs) with and without current collecting electrodes (CCEs) were analyzed using electrochemical impedance spectroscopy (EIS) with a finite element method (FEM). Three different DSC models with or without current collecting electrodes were designed. Theoretical values of the internal resistance were estimated by FEM on changing the position and size of the current collecting electrodes. Large DSCs with current collecting electrodes were fabricated using a screen-printing technique, and experimental values of the internal resistance were analyzed by EIS and compared with the theoretical values. The internal resistances obtained from the impedance measurements were in good agreement with those obtained by simulation. The internal resistance was found to decrease with increasing width and thickness of the CCEs, below a threshold value. EIS was found to be extremely useful for evaluating CCE design for improved DSCs.

  2. 电阻抗图象重建的新正则化方法%New Regularization Method in Electrical Impedance Tomography

    Institute of Scientific and Technical Information of China (English)

    侯卫东; 莫玉龙

    2002-01-01

    Image reconstruction in electrical impedance tomography(EIT) is a highly ill-posed inverse problem. Regularization techniques must be used in order to solve the problem. In this paper, a new regularization method based on the spatial filtering theory is proposed. The new regularized reconstruction for EIT is independent of the estimation of impedance distribution, so it can be implemented more easily than the maximum a posteriori(MAP) method. The regularization level in our proposed method varies spatially so as to be suited to the correlation character of the object's impedance distribution. We implemented our regularization method with two dimensional computer simulations. The experimental results indicate that the quality of the reconstructed impedance images with the descibed regularization method based on spatial filtering theory is better than that with Tikhonov method.

  3. Impedance Scaling and Impedance Control

    Energy Technology Data Exchange (ETDEWEB)

    Chou, W.; Griffin, J.

    1997-06-01

    When a machine becomes really large, such as the Very Large Hadron Collider (VLHC), of which the circumference could reach the order of megameters, beam instability could be an essential bottleneck. This paper studies the scaling of the instability threshold vs. machine size when the coupling impedance scales in a ``normal`` way. It is shown that the beam would be intrinsically unstable for the VLHC. As a possible solution to this problem, it is proposed to introduce local impedance inserts for controlling the machine impedance. In the longitudinal plane, this could be done by using a heavily detuned rf cavity (e.g., a biconical structure), which could provide large imaginary impedance with the right sign (i.e., inductive or capacitive) while keeping the real part small. In the transverse direction, a carefully designed variation of the cross section of a beam pipe could generate negative impedance that would partially compensate the transverse impedance in one plane.

  4. Experimental determination of the admittances of aluminized propellants by the impedance tube method

    Science.gov (United States)

    Baum, J. D.; Daniel, B. R.; Zinn, B. T.

    1980-01-01

    The adaptation of the impedance tube concept for the determination of the pressure coupled admittances and response functions of burning solid propellants is discussed. The results obtained in experiments with UTP-3001 and UTP-19360 aluminized propellants are presented. It is shown that the admittance Y remains constant during the quasi-steady burn period of a test, indicating constant driving of the gas phase disturbance by the burning solid propellant. The measured real part of the admittance is positive, indicating that the burning aluminized propellant is driving the gas phase oscillations. In addition, the measured high gas phase damping, provided by the aluminum oxide particles in the gas phase, suggests that the latter can significantly increase the damping in unstable solid rockets over the investigated frequency range. Finally, it is shown that the wave structure obtained by numerically solving the impedance tube wave equations which utilize the determined propellant admittance as an initial condition and the determined value of G to describe the gas phase losses is in excellent agreement with the measured wave structure.

  5. A New Impedance Matching Method for an Ultra-Wide Band and Dual Circularly Polarised Feed

    Science.gov (United States)

    Li, Sha; Yan, Yi Hua; Wang, Wei; Chen, Zhi Jun; Liu, Dong Hao; Zhang, Fu Shun; Jeffrey, Natasha

    2016-12-01

    In traditional antenna design, metal components are not placed in the central part of the antenna as they change the characteristics of near field radiation. However, we show that placing a metal ring in the centre of the strip lines, which connect the ends of folded high-frequency dipoles, does not damage the performance of the feed. Instead it significantly improves the voltage standing wave ratio of the feed whilst other performance indicators are not compromised. Thus, our findings show an excellent way of improving the wide band feed. Based on this foundation, a new circularly polarised feed for operation between 0.4 to 2 GHz is introduced for the Chinese Spectral Radioheliograph in this paper. The issue of a feed impedance matching network is investigated. By optimising the impedance matching, the performance of the feed is enhanced with respect to the previous realisations of the Eleven feed. The simulation and experimental results show that the gain of the feed is about 10 dBi, and the VSWR is less than 2:1. In addition, the feed has a low axial ratio, fixed phase centre location, and constant beam width in the range of 0.4 to 2 GHz.

  6. A re-expansion method for determining the acoustical impedance and the scattering matrix for the waveguide discontinuity problem

    Science.gov (United States)

    Homentcovschi, Dorel; Miles, Ronald N.

    2010-01-01

    The paper gives a new method for analyzing planar discontinuities in rectangular waveguides. The method consists of a re-expansion of the normal modes in the two ducts at the junction plane into a system of functions accounting for the velocity singularities at the corner points. As the new expansion has an exponential convergence, only a few terms have to be considered for obtaining the solution of most practical problems. To see how the method works some closed form solutions, obtained by the conformal mapping method, are used to discuss the convergence of the re-expanded series when the number of retained terms increases. The equivalent impedance accounting for nonplanar waves into a plane-wave analysis is determined. Finally, the paper yields the scattering matrix which describes the coupling of arbitrary modes at each side of the discontinuity valid in the case of many propagating modes in both parts of the duct. PMID:20707432

  7. Bioelectricity from kitchen and bamboo waste in a microbial fuel cell.

    Science.gov (United States)

    Moqsud, M Azizul; Omine, Kiyoshi; Yasufuku, Noriyuki; Bushra, Quazi S; Hyodo, Masayuki; Nakata, Yukio

    2014-02-01

    This study evaluated bioelectricity generation by using kitchen garbage (KG) and bamboo waste (BW) as a solid waste management option by a microbial fuel cell (MFC) method. The nutrient content [nitrogen, phosphorus and potassium (NPK)] of the by-products of bioelectricity were also analyzed and assessed for their potential use as a soil amendment. A one-chamber MFC was used for bioelectricity generation in laboratory experiments using both KG and BW. A data-logger recorded voltage every 20 mins at a constant room temperature of 25°C over 45 days. The trend of voltage generation was different for the two organic wastes. In the case of KG, the voltage at the initial stage (0-5 days) increased rapidly and then gradually to a peak of 620 mV. In contrast, the voltage increased gradually to a peak of 540 mV in the case of BW. The by-products of bioelectricity can be used as soil conditioner as its NPK content was in the range of soil conditioner mentioned in other literature. Thus, the MFC has emerged as an efficient and eco-friendly solution for organic waste management, especially in developing and technologically less sophisticated countries, and can provide green and safe electricity from organic waste.

  8. 一种DDR信号阻抗匹配的新方法%New method of DDR signal impedance matching

    Institute of Scientific and Technical Information of China (English)

    王征

    2012-01-01

    There are two ways of DDR signal impedance marching:add the series-resistance in the source or add the shunt-resistance in the terminal.The two methods have their advantages and disadvantages.Source matching will increase the PCB plate area.Terminal matching will increase the power.This paper uses the shunt-capacitor to replace the shunt-resistance,which can solve the problem of PCB layout area,and the problem of single board power increased.It is a new method of DDR signal impedance matching.%DDR信号的阻抗匹配一般有两种方法:源端增加串联电阻和终端增加并联电阻。这两种方法各有利弊。其中源端串阻匹配会增加单板PCB的布板面积,终端并联匹配则会增加单板的功耗。本文则采用并联电容来替代并联电阻,这样即可以解决PCB布板面积的问题,也可以解决单板机功耗增加的问题,是DDR信号匹配的一种新方法。

  9. Transoesophageal detection of heart graft rejection by electrical impedance: Using finite element method simulations

    Science.gov (United States)

    Giovinazzo, G.; Ribas, N.; Cinca, J.; Rosell-Ferrer, J.

    2010-04-01

    Previous studies have shown that it is possible to evaluate heart graft rejection level using a bioimpedance technique by means of an intracavitary catheter. However, this technique does not present relevant advantages compared to the gold standard for the detection of a heart rejection, which is the biopsy of the endomyocardial tissue. We propose to use a less invasive technique that consists in the use of a transoesophageal catheter and two standard ECG electrodes on the thorax. The aim of this work is to evaluate different parameters affecting the impedance measurement, including: sensitivity to electrical conductivity and permittivity of different organs in the thorax, lung edema and pleural water. From these results, we deduce the best estimator for cardiac rejection detection, and we obtain the tools to identify possible cases of false positive of heart rejection due to other factors. To achieve these objectives we have created a thoracic model and we have simulated, with a FEM program, different situations at the frequencies of 13, 30, 100, 300 and 1000 kHz. Our simulation demonstrates that the phase, at 100 and 300 kHz, has the higher sensitivity to changes in the electrical parameters of the heart muscle.

  10. Detecting proton exchange membrane fuel cell hydrogen leak using electrochemical impedance spectroscopy method

    Science.gov (United States)

    Mousa, Ghassan; Golnaraghi, Farid; DeVaal, Jake; Young, Alan

    2014-01-01

    When a proton exchange membrane (PEM) fuel cell runs short of hydrogen, it suffers from a reverse potential fault that, when driven by neighboring cells, can lead to anode catalyst degradation and holes in the membrane due to local heat generation. As a result, hydrogen leaks through the electrically-shorted membrane-electrode assembly (MEA) without being reacted, and a reduction in fuel cell voltage is noticed. Such voltage reduction can be detected by using electrochemical impedance spectroscopy (EIS). To fully understand the reverse potential fault, the effect of hydrogen crossover leakage in a commercial MEA is measured by EIS at different differential pressures between the anode and cathode. Then the signatures of these leaky cells were compared with the signatures of a no-leaky cells at different oxygen concentrations with the same current densities. The eventual intent of this early stage work is to develop an on-board diagnostics system that can be used to detect and possibly prevent cell reversal failures, and to permit understanding the status of crossover or transfer leaks versus time in operation.

  11. Dielectric Properties of Bi4Ti3O12 Ceramics by Impedance Spectroscopic Method

    Institute of Scientific and Technical Information of China (English)

    CHEN Yong; SU Huyin; XUE Simin; LI Zhaozhi; ZHANG Cancan; CHEN Qi; XU Lingfang; CAO Wanqiang; HUANG Zhaoxiang

    2016-01-01

    Various lead-free ceramics have been investigated in search for new high-temperature dielectrics. In particular, Bi4Ti3O12 is a type of ferroelectric ceramics, which is supposed to replace lead-containing ceramics for its outstanding dielectric properties in the near future. Ferroelectric ceramics of Bi4Ti3O12 made by conventional mixed oxide route have been studied by impedance spectroscopy in a wide range of temperature. X-ray diffraction patterns show that Bi4Ti3O12 ceramics are a single-phase of ferroelectric Bi-layered perovskite structure whether it is calcined at 800℃ or after sintering production. This study focused on the effect of the grain size on the electric properties of BIT ceramics. The BIT ceramics with different grain sizes were prepared at different sintering temperatures. Grain becomes coarser with the sintering temperature increasing by 50℃, relative permittivity and dielectric loss also change a lot. When sintered at 1 100℃, r values peak can reach 205.40 at a frequency of 100 kHz, the minimum dielectric losses of four different frequencies make no difference, all close to 0.027. The values ofEa range from 0.52 to 0.68 eV. The dielectric properties of the sample sintered at 1 100℃ are relatively better than those of the other samples by analyzing the relationship of the grain, the internal stresses, the homogeneity and the dielectric properties. SEM can better explain the results of the dielectric spectrum at different sintering temperatures. The results show that Bi4Ti3O12 ceramics are a kind of dielectrics. Thus, Bi4Ti3O12 can be used in high-temperature capacitors and microwave ceramics.

  12. A new non-iterative reconstruction method for the electrical impedance tomography problem

    Science.gov (United States)

    Ferreira, A. D.; Novotny, A. A.

    2017-03-01

    The electrical impedance tomography (EIT) problem consists in determining the distribution of the electrical conductivity of a medium subject to a set of current fluxes, from measurements of the corresponding electrical potentials on its boundary. EIT is probably the most studied inverse problem since the fundamental works by Calderón from the 1980s. It has many relevant applications in medicine (detection of tumors), geophysics (localization of mineral deposits) and engineering (detection of corrosion in structures). In this work, we are interested in reconstructing a number of anomalies with different electrical conductivity from the background. Since the EIT problem is written in the form of an overdetermined boundary value problem, the idea is to rewrite it as a topology optimization problem. In particular, a shape functional measuring the misfit between the boundary measurements and the electrical potentials obtained from the model is minimized with respect to a set of ball-shaped anomalies by using the concept of topological derivatives. It means that the objective functional is expanded and then truncated up to the second order term, leading to a quadratic and strictly convex form with respect to the parameters under consideration. Thus, a trivial optimization step leads to a non-iterative second order reconstruction algorithm. As a result, the reconstruction process becomes very robust with respect to noisy data and independent of any initial guess. Finally, in order to show the effectiveness of the devised reconstruction algorithm, some numerical experiments into two spatial dimensions are presented, taking into account total and partial boundary measurements.

  13. Experimental studies on structural load monitoring using piezoelectric transducer based electromechanical impedance method

    Directory of Open Access Journals (Sweden)

    M.A. Radhika

    2013-02-01

    Full Text Available In general aerospace, civil and mechanical (ACM structures are often subjected to some or the other forms of loading during their service life. It has been reported that about 75% of aerospace structures fail due to fatigue cyclic loading. The civil-structural components are subjected to some form of axial and transverse loading which continuously deteriorates the health of the structure. Mechanical components are also subjected to stresses due to contact pressures between several components. Thus for ACM structures, effective monitoring through-out the entire life is required as these often involve public life and huge investments. Owing to such necessity, researchers around the world are continuously working on the development of smart sensor based effective monitoring techniques. Piezo electric (PZT transducer based electromechanical impedance (EMI is one such technique which was developed for structural health monitoring (SHM. In this technique, PZT transducers are usually attached to the structure to be monitored and are then subjected to unit sinusoidal electric voltage to generate the electromechanical (EM admittance signatures when interrogated to the desired frequency range of excitations. These signatures consist of real (conductance and imaginary (susceptance parts which serve as indicator to predict the structural health. Any deviations in these signatures during the monitoring period indicate disturbance in the structure. However, the EMI technique was not widely explored for structural load monitoring (such as fatigue cyclic load, monotonous load, axial and transverse load compared to damage detection. In this paper, systematic experiments were presented on the specimens for axial load variations, transverse load variations, monotonous and fatigue load variation with discussions on boundary effect and buckling effects. For axial, fatigue, monotonic load, the conductance was found to be effective where as for transverse load

  14. Electrical Impedance Spectroscopy for Quality Assessment of Meat and Fish: A Review on Basic Principles, Measurement Methods, and Recent Advances

    Directory of Open Access Journals (Sweden)

    Xin Zhao

    2017-01-01

    Full Text Available Electrical impedance spectroscopy (EIS, as an effective analytical technique for electrochemical system, has shown a wide application for food quality and safety assessment recently. Individual differences of livestock cause high variation in quality of raw meat and fish and their commercialized products. Therefore, in order to obtain the definite quality information and ensure the quality of each product, a fast and on-line detection technology is demanded to be developed to monitor product processing. EIS has advantages of being fast, nondestructive, inexpensive, and easily implemented and shows potential to develop on-line detecting instrument to replace traditional methods to realize time, cost, skilled persons saving and further quality grading. This review outlines the fundamental theories and two common measurement methods of EIS applied to biological tissue, summarizes its application specifically for quality assessment of meat and fish, and discusses challenges and future trends of EIS technology applied for meat and fish quality assessment.

  15. ANALYSIS OF INTERNALLY GENERATED NOISE OF BIOELECTRIC AMPLIFIERS

    Institute of Scientific and Technical Information of China (English)

    Mashhour Mustafa; Bani Amer

    2003-01-01

    This paper deals with internally generated noise of bioelectric amplifiers that are usually used for processing of bioelectric events. The main purpose of this paper is to present a procedure for analysis of the effects of internal noise generated by the active circuits and to evaluate the output noise of the author's new designed bioelectric amplifier that caused by internal effects to the amplifier circuit itself in order to compare it with the noise generated by conventional amplifiers. The obtained analysis results of internally generated noise showed that the total output noise of bioelectric active circuits does not increase when some of their resistors have a larger value. This behavior is caused by the different transfer functions for the signal and the respective noise sources associated with these resistors. Moreover, the new designed bioelectric amplifier has an output noise less than that for conventional amplifiers. The obtained analysis results were also experimentally verified and the final conclusions were drawn.

  16. Acoustic impedances of ear canals measured by impedance tube

    DEFF Research Database (Denmark)

    Ciric, Dejan; Hammershøi, Dorte

    2007-01-01

    During hearing sensitivity tests, the sound field is commonly generated by an earphone placed on a subject ear. One of the factors that can affect the sound transmission in the ear is the acoustic impedance of the ear canal. Its importance is related to the contribution of other elements involved...... in the transmission such as the earphone impedance. In order to determine the acoustic impedances of human ear canals, the standardized method for measurement of complex impedances used for the measurement of the audiometric earphone impedances is applied. It is based on the transfer function between two microphone...... locations in an impedance tube. The end of the tube representing the measurement plane is placed at the ear canal entrance. Thus, the impedance seen from the entrance inward is measured on 25 subjects. Most subjects participated in the previous measurement of the ratio between the pressures at the open...

  17. Easy installation method of piezoceramic (PZT) transducers for health monitoring of structures using electro-mechanical impedance technique

    Science.gov (United States)

    Annamdas, Venu Gopal Madhav; Radhika, Madhav Annamdas; Yang, Yaowen

    2009-03-01

    Impedance-based structural health monitoring (SHM) technique has been developed using piezo-ceramic (PZT) transducers either by surface bonding or embedding inside the structure to detect damage at the earliest possible stage using signatures. However, this technique requires PZT to be permanently attached to the structures. Furthermore permanent attachment will influence the appearance of the host structure and during replacement of faulty transducer, the use of de bonding tools may spoils the surface and beneath. Hence the present study is aimed to fabricate a portable structure, where PZTs are bonded on it and later the portable structure is attached to the host structure. This portable structure is easy to install during monitoring period and uninstall after recording the monitoring signatures of the host structure. This method protects the surface of the host structure to be monitored and will have same efficiency as that of permanently attached PZTs.

  18. Biohydrogen, bioelectricity and bioalcohols from cellulosic materials

    Energy Technology Data Exchange (ETDEWEB)

    Nissila, M.

    2013-03-01

    The demand for renewable energy is increasing due to increasing energy demand and global warming associated with increasing use of fossil fuels. Renewable energy can be derived from biological production of energy carriers from cellulosic biomass. These biochemical processes include biomass fermentation to hydrogen, methane and alcohols, and bioelectricity production in microbial fuel cells (MFCs). The objective of this study was to investigate the production of different energy carriers (hydrogen, methane, ethanol, butanol, bioelectricity) through biochemical processes. Hydrogen production potential of a hot spring enrichment culture from different sugars was determined, and hydrogen was produced continuously from xylose. Cellulolytic and hydrogenic cultures were enriched on cellulose, cellulosic pulp materials, and on silage at different process conditions. The enrichment cultures were further characterized. The effect of acid pretreatment on hydrogen production from pulp materials was studied and compared to direct pulp fermentation to hydrogen. Electricity and alcohol(s) were simultaneously produced from xylose in MFCs and the exoelectrogenic and alcohologenic enrichment cultures were characterized. In the end, the energy yields obtained from different biochemical processes were determined and compared. In this study, cultures carrying out simultaneous cellulose hydrolysis and hydrogen fermentation were enriched from different sources at different operational conditions. These cultures were successfully utilized for cellulose to hydrogen fermentation in batch systems. Based on these results further research should be conducted on continuous hydrogen production from cellulosic materials.

  19. Microwave Impedance Measurement for Nanoelectronics

    Directory of Open Access Journals (Sweden)

    M. Randus

    2011-04-01

    Full Text Available The rapid progress in nanoelectronics showed an urgent need for microwave measurement of impedances extremely different from the 50Ω reference impedance of measurement instruments. In commonly used methods input impedance or admittance of a device under test (DUT is derived from measured value of its reflection coefficient causing serious accuracy problems for very high and very low impedances due to insufficient sensitivity of the reflection coefficient to impedance of the DUT. This paper brings theoretical description and experimental verification of a method developed especially for measurement of extreme impedances. The method can significantly improve measurement sensitivity and reduce errors caused by the VNA. It is based on subtraction (or addition of a reference reflection coefficient and the reflection coefficient of the DUT by a passive network, amplifying the resulting signal by an amplifier and measuring the amplified signal as a transmission coefficient by a common vector network analyzer (VNA. A suitable calibration technique is also presented.

  20. Assessing the applicability of the earth impedance method for in situ studies of tree root systems

    National Research Council Canada - National Science Library

    Josef Urban; Raphael Bequet; Raphael Mainiero

    2011-01-01

    .... Focusing on tree root systems, the present study assesses the applicability of the EIM. Six hypotheses, deduced from the EIM approach, were tested in several experiments and the results were compared with conventional methods...

  1. Progressive damage detection using the reusable electromechanical impedance method for metal structures with a possibility of weight loss identification

    Science.gov (United States)

    Na, Wongi S.

    2016-05-01

    Damage accumulation in structures may result in a structural failure which is a serious problem when ensuring public safety. Although various non-destructive techniques are available to seek for the existence of damage at an early stage, most of these techniques rely on the experience of the experts. To date, automated structural health monitoring systems have been extensively researched and one of the methods, known as the electromechanical impedance (EMI) method, has shown promising results. However, the EMI method is a local method requiring a large number of sensors for covering large areas such as in bridges and buildings. In addition, attaching these sensors onto a surface can be time consuming since adhesives are used for attaching the sensors where its curing time increases the setting up time even further. In this study, the performance of the reusable piezoelectric (PZT) device for metal structures is examined against two different types of progressive damage scenarios. Overall, the reusable PZT device shown in this study has successfully identified damage with a possibility of weight loss detection.

  2. Electromagnetic Scattering Analysis of Coated Conductors With Edges Using the Method of Auxiliary Sources (MAS) in Conjunction With the Standard Impedance Boundary Condition (SIBC)

    DEFF Research Database (Denmark)

    Anastassiu, H.T.; D.I.Kaklamani, H.T.; Economou, D.P.

    2002-01-01

    A novel combination of the method of auxiliary sources (MAS) and the standard impedance boundary condition (SIBC) is employed in the analysis of transverse magnetic (TM) plane wave scattering from infinite, coated, perfectly conducting cylinders with square cross sections. The scatterer is initia......A novel combination of the method of auxiliary sources (MAS) and the standard impedance boundary condition (SIBC) is employed in the analysis of transverse magnetic (TM) plane wave scattering from infinite, coated, perfectly conducting cylinders with square cross sections. The scatterer...

  3. Development of nuclear thermal hydraulic verification tests and evaluation technology - Development of a sensor for two-phase flow measurement using impedance method

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Moo Whan; Kang, Hie Chan; Kwon, Jung Tae; Huh, Deok; Yang, Hoon Cheul [Pohang University of Science and Technology, Pohang (Korea)

    2000-04-01

    Impedance method was carried out to design the electrode that can measure the void fraction of the bubbly flow in pool reservoir. To find out the optimum electrode shape, Styrofoam-Simulator tests were performed in a specially designed acrylic reservoir. Three kinds of electrodes were designed to compare the measuring characteristics of water-air flow. The resistance increased with the increase of the void fraction and the capacitance decreased with the increase of the void fraction. The resistance is a main parameter to express the nature of the water-air flow in impedance method. Almost of impedance values come out from the resistance. The degree of deviation from the mean-resistance values showed reasonable results. Electrode type-I expressed excellent results among the three electrode shapes. The sensor developed can simultaneously measure the void fraction and the water level. 7 refs., 51 figs., 4 tabs. (Author)

  4. Feature Extraction Method for High Impedance Ground Fault Localization in Radial Power Distribution Networks

    DEFF Research Database (Denmark)

    Jensen, Kåre Jean; Munk, Steen M.; Sørensen, John Aasted

    1998-01-01

    processes and communication systems lead to demands for improved monitoring of power distribution networks so that the quality of power delivery can be kept at a controlled level. The ground fault localization method for each feeder in a network is based on the centralized frequency broadband measurement...... of three phase voltages and currents. The method consists of a feature extractor, based on a grid description of the feeder by impulse responses, and a neural network for ground fault localization. The emphasis of this paper is the feature extractor, and the detection of the time instance of a ground fault...

  5. Complex Impedance of Manganese Ferrite Powders Obtained by Two Different Methods

    Directory of Open Access Journals (Sweden)

    Mălăescu I.

    2015-12-01

    Full Text Available Two samples of manganese ferrite powder were obtained by the calcination method (sample A and hydrothermal method (sample B. The crystal structure of the samples has been determined using X-ray diffraction analysis (XRD. The results shown that the sample A has three phases (FeMnO3, Mn2O3 and Fe2O3 and the prevailing phase is FeMnO3 with perovskite structure and the sample B has only a single phase (MnFe2O4.

  6. Frequency Synchronization Analysis in Digital lock-in Methods for Bio-impedance Determination

    Directory of Open Access Journals (Sweden)

    Brajkovič Robert

    2014-12-01

    Full Text Available The lock-in method is one of the most frequently used methods for reconstruction of measured signals and as such frequently applied in the (bioimpedance method to determine the modulus and phase of the (bioimpedance. In implementation of the method in a (bioimpedance measurement device one has to consider possible non synchronized frequencies of the reference and the analyzed signals as well as potential sources of noise. In this work we analyzed these errors theoretically and experimentally. We show that both amplitude and phase errors depend on the relative difference of the frequencies of the reference and investigated signal as well as the number of integration periods. Theoretically, these errors vanish during the determination of the (bioimpedance modulus and phase. In practical implementation the inaccuracies appear at points of very low determined signal amplitudes due to the limited accuracy of analog to digital converters and are distributed around these points due to other sources of noise inherent in implementation of the measurement device.

  7. Comparison of visual, impedance spectroscopy and laser fluorescence methods in detecting early carious lesions on occlusal surfaces

    Directory of Open Access Journals (Sweden)

    Chalas Renata

    2014-06-01

    Full Text Available The diagnostic management is a very important and integral part of the entire treatment process and has a direct influence on the decision-taking on the choice of the most appropriate form of therapy consistent with current knowledge. Knowledge of the morphology of hard dental tissues lesions has led to the development of quantitative methods for diagnosis and monitoring of dental caries, which enabled the implementation of appropriate treatments aimed at repairing than replacing damaged tissue. The aim of the study was to compare selected diagnostic methods: visual (ICDAS, impedance spectroscopy (CarieScan PRO and laser fluorescence (Diagnodent Pen in detecting caries in grooves on the chewing surfaces of molars and premolars. The obtained results indicated a high concordance of measurements performed with the Diagnodent Pen with the results of visual examination and a lower compliance of visual examination with the results obtained using the CarieScan PRO. A combination of visual and tactile method with tests using advanced technology provides greater opportunity to confirm the diagnosis of carious lesions requiring medical intervention.

  8. Characterisation of human skin impedance at acupuncture point PC4 Ximen and pericardium meridian using the four-electrode method.

    Science.gov (United States)

    Rezaei, Shima; Khorsand, Ali; Jamali, Jamshid

    2012-06-01

    Traditional Chinese medicine offers several theories to explain the mechanism of acupuncture. One of these theories proposes that acupuncture points and meridians have unique electrical properties and their electrical skin impedance is lower than surrounding areas. The aim of this study was to evaluate the differences in electrical skin impedance between PC4 and the pericardium meridian compared with the surrounding areas. Eighteen healthy subjects (10 women) were recruited to participate in the study. An impedance meter based on the four-electrode technique was designed specifically for the study. Twenty-five points were marked on the skin: one on the point PC4, four others on the pericardium meridian and 20 points around it. The electrical impedance of each point was measured with the four-electrode device. The mean electrical skin impedance at PC4 was significantly different from the 20 of the surrounding points but not significantly different from the four adjacent points. The mean skin impedance of the five points over the pericardium meridian was significantly different from that of parallel rows of points using repeated measures analysis of variance (ppericardium meridian is lower than surrounding areas, supporting the idea of different properties of the pericardium meridian compared with the control areas. Evidence on skin impedance at PC4 is inconclusive and further studies are needed.

  9. A sub-domain based regularization method with prior information for human thorax imaging using electrical impedance tomography

    Science.gov (United States)

    In Kang, Suk; Khambampati, Anil Kumar; Jeon, Min Ho; Kim, Bong Seok; Kim, Kyung Youn

    2016-02-01

    Electrical impedance tomography (EIT) is a non-invasive imaging technique that can be used as a bed-side monitoring tool for human thorax imaging. EIT has high temporal resolution characteristics but at the same time it suffers from poor spatial resolution due to ill-posedness of the inverse problem. Often regularization methods are used as a penalty term in the cost function to stabilize the sudden changes in resistivity. In human thorax monitoring, with conventional regularization methods employing Tikhonov type regularization, the reconstructed image is smoothed between the heart and the lungs, that is, it makes it difficult to distinguish the exact boundaries of the lungs and the heart. Sometimes, obtaining structural information of the object prior to this can be incorporated into the regularization method to improve the spatial resolution along with helping create clear and distinct boundaries between the objects. However, the boundary of the heart is changed rapidly due to the cardiac cycle hence there is no information concerning the exact boundary of the heart. Therefore, to improve the spatial resolution for human thorax monitoring during the cardiac cycle, in this paper, a sub-domain based regularization method is proposed assuming the lungs and part of background region is known. In the proposed method, the regularization matrix is modified anisotropically to include sub-domains as prior information, and the regularization parameter is assigned with different weights to each sub-domain. Numerical simulations and phantom experiments for 2D human thorax monitoring are performed to evaluate the performance of the proposed regularization method. The results show a better reconstruction performance with the proposed regularization method.

  10. A non-iterative method for the electrical impedance tomography based on joint sparse recovery

    Science.gov (United States)

    Lee, Ok Kyun; Kang, Hyeonbae; Ye, Jong Chul; Lim, Mikyoung

    2015-07-01

    The purpose of this paper is to propose a non-iterative method for the inverse conductivity problem of recovering multiple small anomalies from the boundary measurements. When small anomalies are buried in a conducting object, the electric potential values inside the object can be expressed by integrals of densities with a common sparse support on the location of anomalies. Based on this integral expression, we formulate the reconstruction problem of small anomalies as a joint sparse recovery and present an efficient non-iterative recovery algorithm of small anomalies. Furthermore, we also provide a slightly modified algorithm to reconstruct an extended anomaly. We validate the effectiveness of the proposed algorithm over the linearized method and the multiple signal classification algorithm by numerical simulations. This work is supported by the Korean Ministry of Education, Sciences and Technology through NRF grant No. NRF-2010-0017532 (to H K), the Korean Ministry of Science, ICT & Future Planning; through NRF grant No. NRF-2013R1A1A3012931 (to M L), the R&D Convergence Program of NST (National Research Council of Science & Technology) of Republic of Korea (Grant CAP-13-3-KERI) (to O K L and J C Y).

  11. Optimization of distribution and characterization of sand reservoir by using extended elastic impedance method in "G" old field

    Science.gov (United States)

    Pranata, G. D.; Rosid, M. S.; Martian, D.

    2017-07-01

    To characterize the hydrocarbon reservoir, we need to consider the reservoir's physical parameter. The conventional seismic method could not display all physical parameters in volume data as vertically displayed on well log data. As geophysical method was improved the physical parameters that existing in well log data can be displayed in volume data by using Extended Elastic Impedance (EEI) method. In the proven field, we apply EEI method to enhance fluid distribution and reservoir characterization of the field. EEI method is resulting volume data that representing both lithology distribution and fluid distribution. Lithology distribution is represented by volume data of mu-rho, porosity and gamma ray whereas fluid distribution is represented by volume data of lambda-rho, Vp/Vs ratio, density, water saturation and resistivity. Both lithology and fluid distribution are displayed in sliced volume data. In the result of the study, EEI method produces a considerably good quality of volume data which has EEI spectrum correlation as minimum as 0.50. Also, each of obtained χ angles of physical parameters is well distributed according to projection categories that were introduced by Connolly and most obtained χ angles have only slightly different, if not exactly same, with χ angle values that were obtained by others previous researchers. In general, all used physical parameters clearly show that the hydrocarbon reservoir exists around some structural traps. Most of the reservoirs have fluid content of oil-gas mixing and gas dominated. Additionally, due to un-existing of shear-wave data in the old field, we use shear-wave synthetic data that is derived or generated from other well log data by using a genetic algorithm.

  12. [Study of bioelectrical properties of acupuncture areas].

    Science.gov (United States)

    Filimon, D V; Zaharia, D; Ciochină, A D; Stratulat, S; Stratone, Ana

    2010-01-01

    The research has as a goal the investigation of the bioelectrical behaviour of the acupunctural areas in order to obtain a scientific substantiation of the correspondence between the extreme--eastern medical tradition and the academical medicine. It is obvious that the Chinese traditional medicine knows a certain mechanism of ensurance of homeostasis of the organisms, a mechanism represented, according to the Chinese medical tradition, by the net of acupuncture points and meridians. The experimental data presented in this paper lead to the discovery of the fact that this net works as the fourth system of integration, the electrical--regulator one. The maintenance of the internal homeostasis of the superior organisms and their adaptation to the environment is ensured by the neuro-endocrine and circulatory systems through a mechanism described by Selye under the name of the Uncertain General Syndrome of Adaptation represented by the hypothalamo-hypophyso-corticoadrenal axis. The evolution of these systems and of their mechanisms can be supervised on the basis of the cortisole concentration. The research emphasized the direct proportionality between the cortisone levels and the variation of the electrical values of the acupuncture points, a fact that demonstrates the involvement of the net of acupuncture points and meridians in the maintenance processes of the homeostasis, control, adjustment and adaptation of the living organisms. Additionally, the analysis of the bioelectrical behavior of the acupuncture areas led to the conclusion that the morpho-functional substrate of this net is the conjunctive tissue. The physical-chemical properties of the interstitial connective tissue assures its working as an electro-regulator system on one side and as a harmonization agent of the neuro-endocrine and circulatory systems on the other side, this aspect being to be developed in a future paper.

  13. SYNTHESIS METHODOLOGY FOR ACTIVE ELEMENT USING IMPEDANCES –BASED BOND GRAPH METHODS

    Directory of Open Access Journals (Sweden)

    Nasta TANASESCU

    2004-12-01

    Full Text Available This paper introduces a synthesis methodology for active elements within systems that uses frequency response function as a basis for describing required behavior. The method is applicable in the design of a new system or in the retrofit of an existing system in which an active element is required or desired. The two basis principles of bond graph modeling are the “reticulation principle” which decomposes a physical into elemental physical laws represented as network elements interacting through ports and the “power postulate” which assembles the complete model through a network of power flows representing the exchange of energy between the elements. Moreover the bond graph model leads to a rigorous definitions of the structure of the associated dynamical equations.

  14. Experimental investigation for an isolation technique on conducting the electromechanical impedance method in high-temperature pipeline facilities

    Science.gov (United States)

    Na, Wongi S.; Lee, Hyeonseok

    2016-11-01

    In general, the pipelines within a nuclear power plant facility may experience high temperatures up to several hundred degrees. Thus it is absolutely vital to monitor these pipes to prevent leakage of radioactive substances which may lead to a catastrophic outcome of the surrounding environment. Over the years, one of the structural health monitoring technique known as the electromechanical impedance (EMI) technique has been of great interests in various fields including civil infrastructures, mechanical and aerospace structures. Although it has one of the best advantages to be able for a single piezoelectric transducer to act as a sensor and an actuator, simultaneously, its low curie temperature makes it difficult for the EMI technique to be conducted at high temperature environment. To overcome this problem, this study shows a method to avoid attaching the piezoelectric transducer directly onto the target structure using a metal wire for damage detection at high temperature. By shifting the frequency to compensate the signature changes subjected to the variations in temperature, the experimental results indicate that damage identification is more successful above 200 oC, making the metal wire method suitable for the EMI technique at high temperature environment.

  15. Electrochemical impedance spectroscopy-a simple method for the characterization of polymer inclusion membranes containing aliquat 336.

    Science.gov (United States)

    O'Rourke, Michelle; Duffy, Noel; Marco, Roland De; Potter, Ian

    2011-06-23

    Electrochemical impedance spectroscopy (EIS) has been used to estimate the non-frequency dependent (static) dielectric constants of base polymers such as poly(vinyl chloride) (PVC), cellulose triacetate (CTA) and polystyrene (PS). Polymer inclusion membranes (PIMs) containing different amounts of PVC or CTA, along with the room temperature ionic liquid Aliquat 336 and plasticizers such as trisbutoxyethyl phosphate (TBEP), dioctyl sebecate (DOS) and 2-nitrophenyloctyl ether (NPOE) have been investigated. In this study, the complex and abstract method of EIS has been applied in a simple and easy to use way, so as to make the method accessible to membrane scientists and engineers who may not possess the detailed knowledge of electrochemistry and interfacial science needed for a rigorous interpretation of EIS results. The EIS data reported herein are internally consistent with a percolation threshold in the dielectric constant at high concentrations of Aliquat 336, which illustrates the suitability of the EIS technique since membrane percolation with ion exchangers is a well-known phenomenon.

  16. Electrochemical Impedance Spectroscopy—A Simple Method for the Characterization of Polymer Inclusion Membranes Containing Aliquat 336

    Directory of Open Access Journals (Sweden)

    Michelle O’Rourke

    2011-06-01

    Full Text Available Electrochemical impedance spectroscopy (EIS has been used to estimate the non-frequency dependent (static dielectric constants of base polymers such as poly(vinyl chloride (PVC, cellulose triacetate (CTA and polystyrene (PS. Polymer inclusion membranes (PIMs containing different amounts of PVC or CTA, along with the room temperature ionic liquid Aliquat 336 and plasticizers such as trisbutoxyethyl phosphate (TBEP, dioctyl sebecate (DOS and 2-nitrophenyloctyl ether (NPOE have been investigated. In this study, the complex and abstract method of EIS has been applied in a simple and easy to use way, so as to make the method accessible to membrane scientists and engineers who may not possess the detailed knowledge of electrochemistry and interfacial science needed for a rigorous interpretation of EIS results. The EIS data reported herein are internally consistent with a percolation threshold in the dielectric constant at high concentrations of Aliquat 336, which illustrates the suitability of the EIS technique since membrane percolation with ion exchangers is a well-known phenomenon.

  17. Electrochemical Impedance Spectroscopy—A Simple Method for the Characterization of Polymer Inclusion Membranes Containing Aliquat 336

    Science.gov (United States)

    O'Rourke, Michelle; Duffy, Noel; De Marco, Roland; Potter, Ian

    2011-01-01

    Electrochemical impedance spectroscopy (EIS) has been used to estimate the non-frequency dependent (static) dielectric constants of base polymers such as poly(vinyl chloride) (PVC), cellulose triacetate (CTA) and polystyrene (PS). Polymer inclusion membranes (PIMs) containing different amounts of PVC or CTA, along with the room temperature ionic liquid Aliquat 336 and plasticizers such as trisbutoxyethyl phosphate (TBEP), dioctyl sebecate (DOS) and 2-nitrophenyloctyl ether (NPOE) have been investigated. In this study, the complex and abstract method of EIS has been applied in a simple and easy to use way, so as to make the method accessible to membrane scientists and engineers who may not possess the detailed knowledge of electrochemistry and interfacial science needed for a rigorous interpretation of EIS results. The EIS data reported herein are internally consistent with a percolation threshold in the dielectric constant at high concentrations of Aliquat 336, which illustrates the suitability of the EIS technique since membrane percolation with ion exchangers is a well-known phenomenon. PMID:24957616

  18. Synthetic electrophysiology: optically controlled oscillators in an engineered bioelectric tissue

    Science.gov (United States)

    McNamara, Harold; Zhang, Hongkang; Werley, Christopher; Cohen, Adam

    Multicellular electrical dynamics underlie crucial physiological functions, but the complexity of natural bioelectricity can obscure the relation of individual components (proteins, cells) to emergent system-level dynamics. Here we introduce optopatch-spiking HEK(OS-HEK) tissue, a minimal synthetic bioelectric tissue with 4 transgenic components that supports optical initiation of propagating electrical waves as well direct optical voltage readout. In conjunction with a home-built inverted microscope capable of patterned illumination, we use this tissue to probe the biophysical attributes of this excitable bioelectric medium, including dispersion relations, curvature-dependent wavefront propagation, electrotonic coupling, and effects of boundaries. We then used chemical patterning to define cellular circuits that support controllable oscillations and which retain memory for more than 2 hours (corresponding to 104 oscillations), constituting a substrate for binary bioelectric data storage. Finally, we use optical patterning of boundary conditions in a physically homogeneous tissue to design dynamically reconfigurable oscillators.

  19. bioelectricity production from cassava mill effluents using microbial ...

    African Journals Online (AJOL)

    user

    2016-04-02

    Apr 2, 2016 ... cassava mill effluent using the MFC technology. Keywords: Bioelectricity ... acceptors for its unlimited availability and its high redox potential [18]. ..... compounds in cells including nucleic acid and other material susceptible to ...

  20. An Analytical Method of Auxiliary Sources Solution for Plane Wave Scattering by Impedance Cylinders - A Reference Solution for the Numerical Method of Auxiliary Sources

    DEFF Research Database (Denmark)

    Larsen, Niels Vesterdal; Breinbjerg, Olav

    2004-01-01

    To facilitate the validation of the numerical Method of Auxiliary Sources an analytical Method of Auxiliary Sources solution is derived in this paper. The Analytical solution is valid for transverse magnetic, and electric, plane wave scattering by circular impedance Cylinders, and it is derived...... by transformation of the exact eigenfunction series solution. The transformation employs the Hankel function wave transformation to express the eigenfunction series of higher-order Hankel functions, with their singularities at the coordinate system origin as a superposition of zero-order Hankel functions...... with their singularities at different positions away from the origin. The transformation necessitates a truncation of the wave transformation but the inaccuracy introduced hereby is shown to be negligible. The analytical Method of Auxiliary Sources solution is employed as a reference to investigate the accuracy...

  1. Electromagnetic Scattering Analysis of Coated Conductors With Edges Using the Method of Auxiliary Sources (MAS) in Conjunction With the Standard Impedance Boundary Condition (SIBC)

    DEFF Research Database (Denmark)

    Anastassiu, H.T.; D.I.Kaklamani, H.T.; Economou, D.P.;

    2002-01-01

    A novel combination of the method of auxiliary sources (MAS) and the standard impedance boundary condition (SIBC) is employed in the analysis of transverse magnetic (TM) plane wave scattering from infinite, coated, perfectly conducting cylinders with square cross sections. The scatterer is initia...

  2. Optically stimulated differential impedance spectroscopy

    Science.gov (United States)

    Maxey, Lonnie C; Parks, II, James E; Lewis, Sr., Samuel A; Partridge, Jr., William P

    2014-02-18

    Methods and apparatuses for evaluating a material are described. Embodiments typically involve use of an impedance measurement sensor to measure the impedance of a sample of the material under at least two different states of illumination. The states of illumination may include (a) substantially no optical stimulation, (b) substantial optical stimulation, (c) optical stimulation at a first wavelength of light, (d) optical stimulation at a second wavelength of light, (e) a first level of light intensity, and (f) a second level of light intensity. Typically a difference in impedance between the impedance of the sample at the two states of illumination is measured to determine a characteristic of the material.

  3. Impedance of accelerator components

    Energy Technology Data Exchange (ETDEWEB)

    Corlett, J.N. [Center for Beam Physics, Lawrence Berkeley National Laboratory, I Cyclotron Road, Berkeley, California 94720 (United States)

    1997-01-01

    As demands for high luminosity and low emittance particle beams increase, an understanding of the electromagnetic interaction of these beams with their vacuum chamber environment becomes more important in order to maintain the quality of the beam. This interaction is described in terms of the wake field in time domain, and the beam impedance in frequency domain. These concepts are introduced, and related quantities such as the loss factor are presented. The broadband Q=1 resonator impedance model is discussed. Perturbation and coaxial wire methods of measurement of real components are reviewed. {copyright} {ital 1997 American Institute of Physics.}

  4. Impedance modelling of pipes

    Science.gov (United States)

    Creasy, M. Austin

    2016-03-01

    Impedance models of pipes can be used to estimate resonant frequencies of standing waves and model acoustic pressure of closed and open ended pipes. Modelling a pipe with impedance methods allows additional variations to the pipe to be included in the overall model as a system. Therefore an actuator can be attached and used to drive the system and the impedance model is able to include the dynamics of the actuator. Exciting the pipe system with a chirp signal allows resonant frequencies to be measured in both the time and frequency domain. The measurements in the time domain are beneficial for introducing undergraduates to resonances without needing an understanding of fast Fourier transforms. This paper also discusses resonant frequencies in open ended pipes and how numerous texts incorrectly approximate the resonant frequencies for this specific pipe system.

  5. Electrical impedance characterization of normal and cancerous human hepatic tissue.

    Science.gov (United States)

    Laufer, Shlomi; Ivorra, Antoni; Reuter, Victor E; Rubinsky, Boris; Solomon, Stephen B

    2010-07-01

    The four-electrode method was used to measure the ex vivo complex electrical impedance of tissues from 14 hepatic tumors and the surrounding normal liver from six patients. Measurements were done in the frequency range 1-400 kHz. It was found that the conductivity of the tumor tissue was much higher than that of the normal liver tissue in this frequency range (from 0.14 +/- 0.06 S m(-1) versus 0.03 +/- 0.01 S m(-1) at 1 kHz to 0.25 +/- 0.06 S m(-1) versus 0.15 +/- 0.03 S m(-1) at 400 kHz). The Cole-Cole models were estimated from the experimental data and the four parameters (rho(0), rho(infinity), alpha, f(c)) were obtained using a least-squares fit algorithm. The Cole-Cole parameters for the cancerous and normal liver are 9 +/- 4 Omega m(-1), 2.2 +/- 0.7 Omega m(-1), 0.5 +/- 0.2, 140 +/- 103 kHz and 50 +/- 28 Omega m(-1), 3.2 +/- 0.6 Omega m(-1), 0.64 +/- 0.04, 10 +/- 7 kHz, respectively. These data can contribute to developing bioelectric applications for tissue diagnostics and in tissue treatment planning with electrical fields such as radiofrequency tissue ablation, electrochemotherapy and gene therapy with reversible electroporation, nanoscale pulsing and irreversible electroporation.

  6. Brain bioelectrical activity changes in patients with poststroke depression and apathy

    Directory of Open Access Journals (Sweden)

    I. V. Kichuk

    2015-01-01

    Full Text Available Objective: to study the specific features of brain bioelectrical activity in patents with poststroke apathy and depressive disorders.Patients and methods. The investigation enrolled 175 patients (84 men and 91 women with new-onset cerebral stroke at different sites. A total of 107 (61% patients of them were observed to have depressive disorders (n=41 (38% and apathy (n=66 (62% within a year after disease onset. A control group included 68 (39% patients without poststroke affective disorders. The mean age of the study group patients was 66±10 years and that of the control patients was 68±11 years. The severity and magnitude of neurological deficit were evaluated using the U.S. National Institutes of Health Stroke Scale (NIHSS. The patients underwent electroencephalography (EEG, brain computed tomography and magnetic resonance imaging. The investigators used diagnostic and statistical manual of mental disorders (DSM-IV criteria to diagnose depression and the Hamilton depression rating scale (HAM-D and the mini-mental status examination (MMSE to evaluate the mental status. The basic rhythmic power indices in the affected and unaffected hemispheres were calculated, as well as anteroposterior alpha rhythm distribution coefficient and interhemispheric asymmetry coefficient. Results and discussion. The computer EEG analysis was shown to identify the hallmark characteristics of brain bioelectric activity in patients with different types of affective disorders in the acute, early and late recovery periods of stroke. The patients with affective disorders were found to have brain bioelectrical activity changes predominantly in the rapid frequency sub-band on EEG, suggesting midbrain structural dysfunction. In the patients with poststroke depression, depressive disorder scale scores were related to the power of bioelectric activity in the slow and alpha frequency bands manly in the acute stroke period whereas those were correlated with the EEG

  7. Impedance plethysmography: basic principles.

    Directory of Open Access Journals (Sweden)

    Babu J

    1990-04-01

    Full Text Available Impedance Plethysmography technique has been discussed with explanation of two compartment model and parallel conductor theory for the estimation of peripheral blood flow and stroke volume. Various methods for signal enhancement to facilitate computation of blood flow are briefly described. Source of error in the estimation of peripheral blood flow is identified and the correction has been suggested.

  8. Implantable Impedance Plethysmography

    OpenAIRE

    2014-01-01

    We demonstrate by theory, as well as by ex vivo and in vivo measurements that impedance plethysmography, applied extravascularly directly on large arteries, is a viable method for monitoring various cardiovascular parameters, such as blood pressure, with high accuracy. The sensor is designed as an implant to monitor cardiac events and arteriosclerotic progression over the long term.

  9. Implantable Impedance Plethysmography

    Directory of Open Access Journals (Sweden)

    Michael Theodor

    2014-08-01

    Full Text Available We demonstrate by theory, as well as by ex vivo and in vivo measurements that impedance plethysmography, applied extravascularly directly on large arteries, is a viable method for monitoring various cardiovascular parameters, such as blood pressure, with high accuracy. The sensor is designed as an implant to monitor cardiac events and arteriosclerotic progression over the long term.

  10. Short-circuit impedance measurement

    DEFF Research Database (Denmark)

    Pedersen, Knud Ole Helgesen; Nielsen, Arne Hejde; Poulsen, Niels Kjølstad

    2003-01-01

    Methods for estimating the short-circuit impedance in the power grid are investigated for various voltage levels and situations. The short-circuit impedance is measured, preferably from naturally occurring load changes in the grid, and it is shown that such a measurement system faces different...

  11. 基于生物电阻抗的血型检测新方法及系统实现%New Method for Blood Type Detection Based on Bioelectrical lmpedance Analysis Technology and its System lmplementation

    Institute of Scientific and Technical Information of China (English)

    陈里里; 廖强; 胡雪; 张国珍

    2014-01-01

    A new method for blood type detection and a new automated blood typing system are developed. In the system,the combined use of the AD9850 chip and MCU are employed to realize the DDS technique and produce excitation signal. Then an elliptic filter is designed to eliminate the signal interference,and an amplitude stabilized circuit is designed to stabilize the amplitude of the signal output by using an AD8370 chip,which is a low-cost variable gain amplifier. The amplitude and phase measurement chip AD8302 is adopted to extract the impedance information. Based on neural network recognition model,a new method is designed to determine the degree of agglutination in red blood cell suspension. The use of this method combined with the discriminant rule could successfully identify the blood type. Contrastive test is carried out and the new system showed high measurement accuracy and good stability,could better distinguish the different intensity of agglutination in red blood cell,and identified ABO and Rh blood type correctly in normal samples. The self-developed new automated blood typing system is in better agreement with clinical requirements.%提出了基于生物电阻抗测量技术的血型检测新方法并研制了检测系统。该系统采用单片机结合AD9850芯片实现 DDS 技术产生激励信号,设计椭圆滤波器消除信号干扰;运用低成本放大器 AD8370设计稳幅电路,确保信号输出幅度不变;系统采用 AD8302幅相检测芯片实现阻抗信息提取;基于人工神经网络判别红细胞悬浮液凝集强度,并结合判别规则得到血型结果。测试结果表明该系统精度高,稳定性好;临床实验表明,该系统能正确识别红细胞6种不同凝集程度,能100%正确地检测出正常标本的 ABO 和 Rh 血型,可更好地满足临床需求。

  12. Evaluation of moisturizing effect of methanolic extract of five medicinal plants incorporated into cream bases using impedance and extensiometry methods.

    Science.gov (United States)

    Khazaeli, Payam; Sharififar, Fariba; Amiri, Fahimeh; Heravi, Gioia; Heravi, Gioia

    2011-10-01

    Skin moisturizing is an important issue due to its impact on skin function. Adverse reactions to herbal extracts have been rarely reported and can be used in moisturizers. This study was conduct to evaluate moisturizing effect of a methanolic extract of five medicinal plants incorporated into cream bases. Methanolic extract of five medicinal plants including olive, burdock, licorice, mallow and marsh horsetail was prepared. The extracts were dissolved in distilled water completely and freeze-dried to a dry powder. These extracts were added separately to the cream based formulation that has been suggested to be appropriate for adding herbal extracts. Moisturizing effects of these creams with herbal extracts were assessed using the impedance method on 12 rats equally divided into six groups (one control and five cases), as well as the extensiometry method on 25 mice divided into five groups (in each group one cream with herbal extract and control cream were tested concurrently). Obtained results were compared with the control cream based. The maximum moisturizing effect was observed with the marsh horsetail. Other creams with herbal extracts, except the one with the licorice, also exerted significantly higher moisturizing effect compared to the controls (P<0.05). Regarding the force for skin tearing, the differences were statistically significant in all groups when compared to the control group (P<0.05) and the highest difference was seen in the marsh horsetail group (2.0832 ± 0.6811 kgN). The highest moisturizing activity was observed using marsh horsetail extract that can be explained by flavonoids content of marsh horsetail.

  13. Characterization of full set material constants of piezoelectric materials based on ultrasonic method and inverse impedance spectroscopy using only one sample.

    Science.gov (United States)

    Li, Shiyang; Zheng, Limei; Jiang, Wenhua; Sahul, Raffi; Gopalan, Venkatraman; Cao, Wenwu

    2013-09-14

    The most difficult task in the characterization of complete set material properties for piezoelectric materials is self-consistency. Because there are many independent elastic, dielectric, and piezoelectric constants, several samples are needed to obtain the full set constants. Property variation from sample to sample often makes the obtained data set lack of self-consistency. Here, we present a method, based on pulse-echo ultrasound and inverse impedance spectroscopy, to precisely determine the full set physical properties of piezoelectric materials using only one small sample, which eliminated the sample to sample variation problem to guarantee self-consistency. The method has been applied to characterize the [001]C poled Mn modified 0.27Pb(In1/2Nb1/2)O3-0.46Pb(Mg1/3Nb2/3)O3-0.27PbTiO3 single crystal and the validity of the measured data is confirmed by a previously established method. For the inverse calculations using impedance spectrum, the stability of reconstructed results is analyzed by fluctuation analysis of input data. In contrast to conventional regression methods, our method here takes the full advantage of both ultrasonic and inverse impedance spectroscopy methods to extract all constants from only one small sample. The method provides a powerful tool for assisting novel piezoelectric materials of small size and for generating needed input data sets for device designs using finite element simulations.

  14. Method to detect the end-point for PCR DNA amplification using an ionically labeled probe and measuring impedance change

    Science.gov (United States)

    Miles, Robin R.; Belgrader, Phillip; Fuller, Christopher D.

    2007-01-02

    Impedance measurements are used to detect the end-point for PCR DNA amplification. A pair of spaced electrodes are located on a surface of a microfluidic channel and an AC or DC voltage is applied across the electrodes to produce an electric field. An ionically labeled probe will attach to a complementary DNA segment, and a polymerase enzyme will release the ionic label. This causes the conductivity of the solution in the area of the electrode to change. This change in conductivity is measured as a change in the impedance been the two electrodes.

  15. Bioelectric signaling regulates size in zebrafish fins.

    Directory of Open Access Journals (Sweden)

    Simon Perathoner

    2014-01-01

    Full Text Available The scaling relationship between the size of an appendage or organ and that of the body as a whole is tightly regulated during animal development. If a structure grows at a different rate than the rest of the body, this process is termed allometric growth. The zebrafish another longfin (alf mutant shows allometric growth resulting in proportionally enlarged fins and barbels. We took advantage of this mutant to study the regulation of size in vertebrates. Here, we show that alf mutants carry gain-of-function mutations in kcnk5b, a gene encoding a two-pore domain potassium (K(+ channel. Electrophysiological analysis in Xenopus oocytes reveals that these mutations cause an increase in K(+ conductance of the channel and lead to hyperpolarization of the cell. Further, somatic transgenesis experiments indicate that kcnk5b acts locally within the mesenchyme of fins and barbels to specify appendage size. Finally, we show that the channel requires the ability to conduct K(+ ions to increase the size of these structures. Our results provide evidence for a role of bioelectric signaling through K(+ channels in the regulation of allometric scaling and coordination of growth in the zebrafish.

  16. An impedance method for spatial sensing of 3D cell constructs – towards applications in tissue engineering

    DEFF Research Database (Denmark)

    Canali, Chiara; Mazzoni, Chiara; Larsen, Layla Bashir

    2015-01-01

    ) cells were encapsulated in gelatin to form artificial 3D cell constructs and detected when placed in different positions inside large gelatin scaffolds. Taken together, these results open new perspectives for impedance-based sensing technologies for non-invasive monitoring in tissue engineering...

  17. ANALYSIS OF INTERNALLY GENERATED NOISE OF BIOELECTRIC AMPLIFIERS

    Institute of Scientific and Technical Information of China (English)

    MashhourMustafaBaniAmer

    2003-01-01

    This papenr deals with internally generated noise of bioelectric amplifiers that are usually used for processing of bioelectric events.The main purpose of this paper is to present a procedure for analysis of the effects of internal noise generated by the active circuits and to evaluate the output noise of the author's new designed bioelectric amplifier that caused by internal effects to the amplifier circuit itself in order to compare it with the noise generated by conventional amplifiers.The obtained analysis results of internally generated noise showed that the total output noise of bioelectric active circuits does not increase when some of their resitors have a larger value.This behavior is caused by the different transfer functions for the signal and the respective noise sources associated with these resistors.Moreover,the new designed bioelectric amplifier haws an output noise less than that for conventional amplifiers.The obtained analysis results were also experimentally verified and the final conclusions were drawn.

  18. Impedance source power electronic converters

    CERN Document Server

    Liu, Yushan; Ge, Baoming; Blaabjerg, Frede; Ellabban, Omar; Loh, Poh Chiang

    2016-01-01

    Impedance Source Power Electronic Converters brings together state of the art knowledge and cutting edge techniques in various stages of research related to the ever more popular impedance source converters/inverters. Significant research efforts are underway to develop commercially viable and technically feasible, efficient and reliable power converters for renewable energy, electric transportation and for various industrial applications. This book provides a detailed understanding of the concepts, designs, controls, and application demonstrations of the impedance source converters/inverters. Key features: Comprehensive analysis of the impedance source converter/inverter topologies, including typical topologies and derived topologies. Fully explains the design and control techniques of impedance source converters/inverters, including hardware design and control parameter design for corresponding control methods. Presents the latest power conversion solutions that aim to advance the role of pow...

  19. Comparison of bioelectrical impedance with skinfold thickness and X-ray absorptiometry to measure body composition in HIV-infected with lipodistrophy Comparación de impendancia bioeléctrica con grosor de pliegues cutáneos y absorciometría de rayos X para mensurar la composición corporal de personas con VIH con lipodistrofia

    OpenAIRE

    H. Siqueira Vassimon; JORDAO, A. A.; F. J. Albuquerque de Paula; A. Artioli Machado; J. Pontes Monteiro

    2011-01-01

    Introduction: Human immunodeficiency vírus (HIV)-associated lipodystrophy syndrome (LS) includes body composition and metabolic alterations. Lack of validated criteria and tools make difficult to evaluate body composition in this group. Objective: The aim of the study was to compare different methods to evaluate body composition between Brazilians HIV subjects with (HIV+LIPO+) or without LS (HIV+LIPO-) and healthy subjects (Control). Methods: in a cross-sectional analyses, body composition wa...

  20. RECIPROCITY CALIBRATION OF A SONAR TRANSDUCER FROM ELECTRICAL IMPEDANCE MEASUREMENTS IN WATER AND IN AIR : THE DELTA-Z RECIPROCITY CALIBRATION METHOD

    OpenAIRE

    S. Baker(Department of Physics and Astronomy, University College London, London, United Kingdom); Bedard, R.; Patton, M.; Wilson, O.

    1990-01-01

    A method is described by which the free-field, open-circuit voltage sensitivity of a reversible underwater acoustic transducer may be obtained from measurements of its input electrical impedance in water and in air. This method, which we have termed the Delta-Z reciprocity calibration method, is being developed for the in-service calibration of sonar transducers installed in domes which can be flooded and purged. The application of the Delta-Z method to the calibration of a single tonpilz-typ...

  1. Electrochemical Impedance Spectroscopy—A Simple Method for the Characterization of Polymer Inclusion Membranes Containing Aliquat 336

    OpenAIRE

    Michelle O’Rourke; Noel Duffy; Roland De Marco; Ian Potter

    2011-01-01

    Electrochemical impedance spectroscopy (EIS) has been used to estimate the non-frequency dependent (static) dielectric constants of base polymers such as poly(vinyl chloride) (PVC), cellulose triacetate (CTA) and polystyrene (PS). Polymer inclusion membranes (PIMs) containing different amounts of PVC or CTA, along with the room temperature ionic liquid Aliquat 336 and plasticizers such as trisbutoxyethyl phosphate (TBEP), dioctyl sebecate (DOS) and 2-nitrophenyloctyl ether (NPOE) have been in...

  2. Effect of photostimulation on maize leaves’ bioelectrical response

    Directory of Open Access Journals (Sweden)

    M. P. Motsnyj

    2011-06-01

    Full Text Available Dynamics of the maize leaves’ biopotentials evoked by white, blue, green and red light stimuli with an intensity of 90 Lx illumination is analyzed. Qualitative similarity in dynamics of plant’s bioelectrical response to white and colored stimuli is determined. Hyperpolarization levels are quantitatively estimated for each experimental series. Dependence of the total hyperpolarization levels on the photostimulus wave length is detected. Mean amplitude of the hyperpolarization potentials lessens when the wave length decreases: from 57.7 mV under the red light to 27.7 mV under the blue one. Probable forms of bioelectrical response initiation in photostimulated plants are analyzed.

  3. Structural and impedance studies of LiNi0.5Mn1.5O4 synthesized by sol-gel method

    Science.gov (United States)

    Lobo, Laurel Simon; Rubankumar, A.; Kalainathan, S.

    2016-05-01

    LiNi0.5Mn1.5O4 is synthesized by sol-gel method by using succinic acid as chelating agent. X-ray diffraction pattern confirms the material is spinel cubic structure with Fd3m space group. Impedance spectroscopy analysis of spinel LiNi0.5Mn1.5O4 was performed under a wide frequency and temperature range of 50 Hz to 5 MHz and 303 K to 783 K respectively. The hopping of the electrons, ionic conductivity and activation energy were analyzed from the relaxation frequency of the imaginary impedance (Z"). The activation energy Ea is calculated from the Arrhenius plots and it is found to be 0.3713 eV, which indicates the existence of oxygen vacancy in the material. Nyquist plot indicates the presence of grain effect in the material and suppression in the grain effect is observed with increasing temperature.

  4. Electromechanical method coupling non-invasive skin impedance probing and in vivo subcutaneous liquid microinjection: controlling the diffusion pattern of nanoparticles within living soft tissues.

    Science.gov (United States)

    Sung, Baeckkyoung; Kim, Se Hoon; Lee, Jin-Kyu; Lee, Byung-Cheon; Soh, Kwang-Sup

    2014-08-01

    Transdermal drug delivery is the way to transport drug carriers, such as nanoparticles, across the skin barrier to the dermal and/or subcutaneous layer. In order to control the transdermal drug delivery process, based on the heterogeneous and nonlinear structures of the skin tissues, we developed a novel electromechanical method combining in vivo local skin impedance probing, subcutaneous micro-injection of colloidal nanoparticles, and transcutaneous electrical stimulation. Experiments on the nude mice using in vivo fluorescence imaging exhibited significantly different apparent diffusion patterns of the nanoparticles depending on the skin impedance: Anisotropic and isotropic patterns were observed upon injection into low and high impedance points, respectively. This result implies that the physical complexity in living tissues may cause anisotropic diffusion of drug carriers, and can be used as a parameter for controlling drug delivery process. This method also can be combined with microneedle-based drug release systems, micro-fabricated needle-electrodes, and/or advanced in vivo targeting/imaging technologies using nanoparticles.

  5. A 3D Multiport Scattering Matrix Based-Method for Educing Wall Impedance of Cylindrical Lined Duct Section: Simulation and Error Evaluation

    Directory of Open Access Journals (Sweden)

    Mohamed Taktak

    2009-01-01

    Full Text Available The first step to achieve the development of an original indirect method to educe the wall normalized acoustic impedance of a cylindrical lined duct section which includes frequency and modal content pressure field dependence is introduced. It is based on the minimization of the difference between numerical and experimental acoustic power dissipations deduced from the 3D numerical and experimental scattering matrices of a lined duct element. The work presented in this paper is a step toward conducting experiments with a flow duct facility developed during the European DUCAT program. To validate this eduction technique, a simulation of the experiment is performed for no flow conditions assuming an axi-symmetric wall lined with a locally reacting material whose impedance was measured with the two microphone method (TMM. The simulation conducted for two incident pressure vectors with a Monte Carlo's technique also provides an assessment of the uncertainty in three predominant experimental parameters on the scattering matrix coefficients, the acoustic power dissipation, and the educed impedance whose results will be useful during the experiments being conducted.

  6. Acoustic ground impedance meter

    Science.gov (United States)

    Zuckerwar, A. J. (Inventor)

    1984-01-01

    A method and apparatus are presented for measuring the acoustic impedance of a surface in which the surface is used to enclose one end of the chamber of a Helmholz resonator. Acoustic waves are generated in the neck of the resonator by a piston driven by a variable speed motor through a cam assembly. The acoustic waves are measured in the chamber and the frequency of the generated acoustic waves is measured by an optical device. These measurements are used to compute the compliance and conductance of the chamber and surface combined. The same procedure is followed with a calibration plate having infinite acoustic impedance enclosing the chamber of the resonator to compute the compliance and conductance of the chamber alone. Then by subtracting, the compliance and conductance for the surface is obtained.

  7. High-impedance wire grid method to study spatiotemporal behavior of hot electron clump generated in a plasma.

    Science.gov (United States)

    Terasaka, K; Yoshimura, S; Kato, Y; Furuta, K; Aramaki, M; Morisaki, T; Tanaka, M Y

    2014-11-01

    High-impedance Wire Grid (HIWG) detector has been developed to study spatiotemporal behavior of a hot electron clump generated in an electron cyclotron resonance (ECR) plasma. By measuring the floating potentials of the wire electrodes, and generating structure matrix made of geometrical means of the floating potentials, the HIWG detector reconstructs the spatial distribution of high-temperature electron clump at an arbitrary instant of time. Time slices of the spike event in floating potential revealed the growth and decay process of a hot spot occurs in an ECR plasma.

  8. Compost in plant microbial fuel cell for bioelectricity generation

    NARCIS (Netherlands)

    Moqsud, M.A.; Yoshitake, J.; Bushra, Q.S.; Hyodo, M.; Omine, K.; Strik, D.P.B.T.B.

    2015-01-01

    Recycling of organic waste is an important topic in developing countries as well as developed countries. Compost from organic waste has been used for soil conditioner. In this study, an experiment has been carried out to produce green energy (bioelectricity) by using paddy plant microbial fuel cells

  9. Carbon fiber enhanced bioelectricity generation in soil microbial fuel cells.

    Science.gov (United States)

    Li, Xiaojing; Wang, Xin; Zhao, Qian; Wan, Lili; Li, Yongtao; Zhou, Qixing

    2016-11-15

    The soil microbial fuel cell (MFC) is a promising biotechnology for the bioelectricity recovery as well as the remediation of organics contaminated soil. However, the electricity production and the remediation efficiency of soil MFC are seriously limited by the tremendous internal resistance of soil. Conductive carbon fiber was mixed with petroleum hydrocarbons contaminated soil and significantly enhanced the performance of soil MFC. The maximum current density, the maximum power density and the accumulated charge output of MFC mixed carbon fiber (MC) were 10, 22 and 16 times as high as those of closed circuit control due to the carbon fiber productively assisted the anode to collect the electron. The internal resistance of MC reduced by 58%, 83% of which owed to the charge transfer resistance, resulting in a high efficiency of electron transfer from soil to anode. The degradation rates of total petroleum hydrocarbons enhanced by 100% and 329% compared to closed and opened circuit controls without the carbon fiber respectively. The effective range of remediation and the bioelectricity recovery was extended from 6 to 20cm with the same area of air-cathode. The mixed carbon fiber apparently enhanced the bioelectricity generation and the remediation efficiency of soil MFC by means of promoting the electron transfer rate from soil to anode. The use of conductively functional materials (e.g. carbon fiber) is very meaningful for the remediation and bioelectricity recovery in the bioelectrochemical remediation.

  10. Bioelectric Control of a 757 Class High Fidelity Aircraft Simulation

    Science.gov (United States)

    Jorgensen, Charles; Wheeler, Kevin; Stepniewski, Slawomir; Norvig, Peter (Technical Monitor)

    2000-01-01

    This paper presents results of a recent experiment in fine grain Electromyographic (EMG) signal recognition, We demonstrate bioelectric flight control of 757 class simulation aircraft landing at San Francisco International Airport. The physical instrumentality of a pilot control stick is not used. A pilot closes a fist in empty air and performs control movements which are captured by a dry electrode array on the arm, analyzed and routed through a flight director permitting full pilot outer loop control of the simulation. A Vision Dome immersive display is used to create a VR world for the aircraft body mechanics and flight changes to pilot movements. Inner loop surfaces and differential aircraft thrust is controlled using a hybrid neural network architecture that combines a damage adaptive controller (Jorgensen 1998, Totah 1998) with a propulsion only based control system (Bull & Kaneshige 1997). Thus the 757 aircraft is not only being flown bioelectrically at the pilot level but also demonstrates damage adaptive neural network control permitting adaptation to severe changes in the physical flight characteristics of the aircraft at the inner loop level. To compensate for accident scenarios, the aircraft uses remaining control surface authority and differential thrust from the engines. To the best of our knowledge this is the first time real time bioelectric fine-grained control, differential thrust based control, and neural network damage adaptive control have been integrated into a single flight demonstration. The paper describes the EMG pattern recognition system and the bioelectric pattern recognition methodology.

  11. Scattering patterns of dihedral corner reflectors with impedance surface impedances

    Science.gov (United States)

    Balanis, Constantine A.; Griesser, Timothy; Liu, Kefeng

    The radar cross section patterns of lossy dihedral corner reflectors are calculated using a uniform geometrical theory of diffraction for impedance surfaces. All terms of up to third order reflections are considered for patterns in the principal plane. The surface waves are included whenever they exist for reactive surface impedances. The dihedral corner reflectors examined have right, obtuse, and acute interior angles, and patterns over the entire 360 deg azimuthal plane are calculated. The surface impedances can be different on the four faces of the dihedral corner reflector; however, the surface impedance must be uniform over each face. Computed cross sections are compared with a moment method technique for a dielectric/ferrite absorber coating on a metallic corner reflector. The analysis of the dihedral corner reflector is important because it demonstrates many of the important scattering contributors of complex targets including both interior and exterior wedge diffraction, half-plane diffraction, and dominant multiple reflections and diffractions.

  12. Feasibility of bioelectrical impedance analysis in children with a severe generalized cerebral palsy

    NARCIS (Netherlands)

    R. Veugelers (Rebekka); C. Penning (Corine); L. van Gulik (Laura); D. Tibboel (Dick); H.M. Evenhuis (Heleen)

    2006-01-01

    textabstractObjective: The need is strong for an accurate and easy-to-perform test to evaluate the nutritional state of children who have a severe generalized cerebral palsy, defined as a severe motor handicap and an intellectual disability. For that purpose, we determined the feasibility of bioelec

  13. Malnutrition in remission of childhood cancers as assessed by bioelectric impedance analysis

    Directory of Open Access Journals (Sweden)

    M. V. Konovalova

    2014-07-01

    Full Text Available The results of our cross-sectional bioimpedance study of children aged 7–17 years cured of cancer during follow-up (patients’ group, n = 552, remission time range 0–15 years and of age-matched healthy controls (n = 1,500 show significant intergroup differences in body height and body composition parameters. The most pronounced alterations in the patients’ group were observed in standardized values of phase angle reflecting a sharp decrease in the percentage of metabolically active body cell mass in fat-free mass. Malnutrition, judged from the prevalence of obesity and low phase angle, was observed in 52.7 % of our patients reaching a maximum of 76.8 % in a subgroup of children with CNS tumors. In view of known association that exists between malnutrition and reduced tolerance to chemotherapy, increased susceptibility to infections and adverse outcomes rate, we recommend using bioimpedance analysis in remission of childhood cancers in order to monitoring and timely correction of nutritional state as well as for prevention of delayed cardiovascular risks.

  14. Malnutrition in remission of childhood cancers as assessed by bioelectric impedance analysis

    Directory of Open Access Journals (Sweden)

    M. V. Konovalova

    2012-01-01

    Full Text Available The results of our cross-sectional bioimpedance study of children aged 7–17 years cured of cancer during follow-up (patients’ group, n = 552, remission time range 0–15 years and of age-matched healthy controls (n = 1,500 show significant intergroup differences in body height and body composition parameters. The most pronounced alterations in the patients’ group were observed in standardized values of phase angle reflecting a sharp decrease in the percentage of metabolically active body cell mass in fat-free mass. Malnutrition, judged from the prevalence of obesity and low phase angle, was observed in 52.7 % of our patients reaching a maximum of 76.8 % in a subgroup of children with CNS tumors. In view of known association that exists between malnutrition and reduced tolerance to chemotherapy, increased susceptibility to infections and adverse outcomes rate, we recommend using bioimpedance analysis in remission of childhood cancers in order to monitoring and timely correction of nutritional state as well as for prevention of delayed cardiovascular risks.

  15. Sensitivity field distributions for segmental bioelectrical impedance analysis based on real human anatomy

    Science.gov (United States)

    Danilov, A. A.; Kramarenko, V. K.; Nikolaev, D. V.; Rudnev, S. G.; Salamatova, V. Yu; Smirnov, A. V.; Vassilevski, Yu V.

    2013-04-01

    In this work, an adaptive unstructured tetrahedral mesh generation technology is applied for simulation of segmental bioimpedance measurements using high-resolution whole-body model of the Visible Human Project man. Sensitivity field distributions for a conventional tetrapolar, as well as eight- and ten-electrode measurement configurations are obtained. Based on the ten-electrode configuration, we suggest an algorithm for monitoring changes in the upper lung area.

  16. [ABDOMINAL BIOELECTRICAL IMPEDANCE ANALYSIS AND ANTHROPOMETRY FOR PREDICTING METABOLIC SYNDROME IN MIDDLE AGED MEN].

    Science.gov (United States)

    Fernández-Vázquez, Rosalía; Millán Romero, Ángel; Barbancho, Miguel Ángel; Alvero-Cruz, José Ramón

    2015-09-01

    Objetivo: la obesidad central tiene una gran relación con el síndrome metabólico. Estudiar la relación de la grasa del tronco, el índice de grasa visceral y las medidas antropométricas con el síndrome metabólico. Métodos: diseño: transversal descriptivo y correlacional. Participaron 75 varones, voluntarios, de distintas profesiones, que accedieron a un reconocimiento médico- laboral, con un rango de edad de 21 a 59 años. Mediciones de peso, talla, índice de masa corporal, perímetro abdominal, perímetro glúteo, índice cintura-cadera y grasa de tronco y nivel de grasa visceral mediante bioimpedanciometría (Tanita AB-140-ViScan) y parámetros bioquímicos: glucosa, colesterol total y triglicéridos. Así mismo, se midió la presión arterial sistólica y diastólica. Se comparan los estados de síndrome metabólico, sobrepeso y obesidad. Resultados: existen correlaciones de las medidas antropométricas con la de grasa de tronco y el nivel de grasa visceral, así como con los parámetros bioquímicos (p obesidad y síndrome metabólico. Conclusiones: la grasa de tronco y los niveles de grasa visceral son muy sensibles y específicos para la detección del síndrome metabólico y la obesidad, aunque no superan a las variables e índices antropométricos. En la condición de sobrepeso, la grasa de tronco y visceral son medidas algo más predictivas que las variables antropométricas.

  17. Prediction of percentage body fat from anthropometry and bioelectrical impedance in Singaporean and Beijing Chinese

    NARCIS (Netherlands)

    Deurenberg, P.; Deurenberg-Yap, M.; Jingzhong Wang,; Fu Po Lin,; Schmidt, G.

    2000-01-01

    Body composition was measured in 205 male and female Beijing Chinese and in 148 male and female Singaporean Chinese, age 34 (mean) (range 18-68) years and body mass index (BMI) 22.3 (15.9-38.5) kg/m 2. In Beijing Siri's two-compartment model based on densitometry was used as a reference technique an

  18. Bioelectrical impedance analysis (BIA) for sarcopenic obesity (SO) diagnosis in young female subjects

    Science.gov (United States)

    González-Correa, C. H.; Caicedo-Eraso, J. C.; S, Villada-Gomez J.

    2013-04-01

    Sarcopenia is defined as a loss of muscle mass depending of ageing and affecting physical function (definition A). A new definition considers excluding mass reduction criterion (definition B). Obesity is pandemic and occurs at all ages. Sarcopenic obesity (SO) implies both processes. The purpose of this study was to compare the results obtained after applying these 2 definitions in 66 aged 22 ± 2.8 years overweight or obese young college women. Percentage body fat (%BF) and skeletal mass index (SMI) were estimated by BIA, muscle function by handgrip strength test (HGS) and physical performance by Harvard step test (HST). There were 9.1% and 90.9% overweight or obese subjects. Twenty nine subjects (43.9%) had decreased HGS and 22 (33.3%) had impaired physical performance. One obese subject (1.5%) met the criteria for sarcopenic obesity by definition A and 9 (13.6%) by definition B. Although a linear regression (α obese, the problematic of SO will be found earlier in life.

  19. EFFECTS OF FOOD AND DRINK INGESTION ON BODY COMPOSITION VARIABLES OF ABDOMINAL BIOELECTRICAL IMPEDANCE.

    Science.gov (United States)

    Fernández Vázquez, Rosalía; Martínez Blanco, Javier; García Vega, María del Mar; Barbancho, Miguel Ángel; Alvero-Cruz, José Ramón

    2015-11-01

    Objetivo: conocer los cambios en la grasa del tronco y el nivel de grasa visceral determinado por BIA abdominal, así como otras medidas antropométricas relacionadas con la grasa abdominal o central después de la ingestión de una comida. Métodos: se realizó un protocolo experimental para evaluar un estudio descriptivo de intervención longitudinal. Los participantes fueron 21 sujetos (10 hombres y 11 mujeres), voluntarios que tuvieron acceso a una evaluación médica, con una edad de 74 años ± 13,43. Las mediciones antropométricas fueron: circunferencia de la cintura máxima en posición de pie, circunferencia de la cintura a nivel del ombligo en posición de decúbito supino y diámetro sagital abdominal (SAD). Además se obtuvo la grasa del tronco y el nivel de grasa visceral, por análisis de impedancia bioeléctrica abdominal, con un dispositivo Tanita AB-140 (ViScan), todo ello antes y después de una ración de comida. Resultados: las medidas antropométricas, como la circunferencia de la cintura en posición supina y SAD, no mostraron diferencias significativas (P > 0,05), después de la ingestión de alimentos, a excepción de un aumento significativo de la circunferencia de la cintura máxima en posición de pie (P 0,05). Los cambios porcentuales de las medidas fueron menores del 2% para la circunferencia de la cintura en posición de pie, para la circunferencia de cintura por Viscan, para el diámetro sagital abdominal y la grasa del tronco, y un 5,9% para el nivel de grasa visceral. Conclusiones: los efectos de una comida y bebida sobre la grasa del tronco y el nivel de grasa visceral, medidas por impedancia bioeléctrica abdominal, son mínimas, aunque siempre es recomendable hacerlo en condiciones de ayuno.

  20. Electrical impedance spectroscopy (EIS)-based evaluation of biological tissue phantoms to study multifrequency electrical impedance tomography (Mf-EIT) systems

    KAUST Repository

    Bera, Tushar Kanti

    2016-03-18

    Abstract: Electrical impedance tomography (EIT) phantoms are essential for the calibration, comparison and evaluation of the EIT systems. In EIT, the practical phantoms are typically developed based on inhomogeneities surrounded by a homogeneous background to simulate a suitable conductivity contrast. In multifrequency EIT (Mf-EIT) evaluation, the phantoms must be developed with the materials which have recognizable or distinguishable impedance variations over a wide range of frequencies. In this direction the impedance responses of the saline solution (background) and a number vegetable and fruit tissues (inhomogeneities) are studied with electrical impedance spectroscopy (EIS) and the frequency responses of bioelectrical impedance and conductivity are analyzed. A number of practical phantoms with different tissue inhomogeneities and different inhomogeneity configurations are developed and the multifrequency impedance imaging is studied with the Mf-EIT system to evaluate the phantoms. The conductivity of the vegetable inhomogeneities reconstructed from the EIT imaging is compared with the conductivity values obtained from the EIS studies. Experimental results obtained from multifrequency EIT reconstruction demonstrate that the electrical impedance of all the biological tissues inhomogenity decreases with frequency. The potato tissue phantom produces better impedance image in high frequency ranges compared to the cucumber phantom, because the cucumber impedance at high frequency becomes lesser than that of the potato at the same frequency range. Graphical Abstract: [Figure not available: see fulltext.] © 2016 The Visualization Society of Japan

  1. Biomass production and control of nutrient leaching of willows using different planting methods with special emphasis on an appraisal of the electrical impedance for roots

    Energy Technology Data Exchange (ETDEWEB)

    Yang Cao

    2011-07-01

    Willow reproduction can be achieved through vertically or horizontally planted cuttings. Conventionally, plantations are established by inserting cuttings vertically into the soil. There is, however, a lack of information about the biomass production and nutrient leaching of plantations established through horizontally planted cuttings. A greenhouse experiment and a field trial were carried out to investigate whether horizontally planted Salix schwerinii cuttings have a positive effect on stem yield, root distribution and nutrient leaching in comparison with vertically planted cuttings with different planting densities. The shoots' height of horizontally planted cuttings was significantly smaller than that of vertically planted cuttings during the first two weeks after planting in the pot experiment. Thereafter, no significant effect of planting orientation on the stem biomass was observed in the two conducted experiments. In both experiments the total stem biomass increased with the planting density. It was also found that the fine root biomass and the specific root length were not affected by the planting orientation or density, while the fine root surface area and the absorbing root surface area (ARSA) were affected only by the planting density. The planting orientation did not affect the nutrient concentrations in the soil leachate, apart from SO{sub 4}-S and PO{sub 4}-P in the pot experiment. The ARSA in the pot experiment was assessed by using the earth impedance method. The applicability of this method was evaluated in a hydroponic study of willow cuttings where root and stem were measured independently. Electrical resistance had a good correlation with the contact area of the roots with the solution. However, the resistance depended strongly on the contact area of the stem with the solution, which caused a bias in the evaluation of root surface area. A similar experimental set-up with electrical impedance spectroscopy was employed to study the

  2. Impedance Source Power Electronic Converters

    DEFF Research Database (Denmark)

    Liu, Yushan; Abu-Rub, Haitham; Ge, Baoming

    Impedance Source Power Electronic Converters brings together state of the art knowledge and cutting edge techniques in various stages of research related to the ever more popular impedance source converters/inverters. Significant research efforts are underway to develop commercially viable...... and technically feasible, efficient and reliable power converters for renewable energy, electric transportation and for various industrial applications. This book provides a detailed understanding of the concepts, designs, controls, and application demonstrations of the impedance source converters/inverters. Key...... control methods. Presents the latest power conversion solutions that aim to advance the role of power electronics into industries and sustainable energy conversion systems. Compares impedance source converter/inverter applications in renewable energy power generation and electric vehicles as well...

  3. Bio-electricity Generation using Jatropha Oil Seed Cake.

    Science.gov (United States)

    Raheman, Hifjur; Padhee, Debasish

    2016-01-01

    The review of patents reveals that Handling of Jatropha seed cake after extraction of oil is essential as it contains toxic materials which create environmental pollution. The goal of this work is complete utilisation of Jatropha seeds. For this purpose, Jatropha oil was used for producing biodiesel and the byproduct Jatropha seed cake was gasified to obtain producer gas. Both biodiesel and producer gas were used to generate electricity. To achieve this, a system comprising gasifier, briquetting machine, diesel engine and generator was developed. Biodiesel was produced successfully using the method patented for biodiesel production and briquettes of Jatropha seed cake were made using a vertical extruding machine. Producer gas was obtained by gasifying these briquettes in a downdraft gasifier. A diesel engine was then run in dual fuel mode with biodiesel and producer gas instead of only diesel. Electricity was generated by coupling it to a generator. The cost of producing kilowatthour of electricity with biodiesel and diesel in dual fuel mode with producer gas was found to be 0.84 $ and 0.75 $, respectively as compared to 0.69 $ and 0.5 $ for the same fuels in single fuel mode resulting in up to 48 % saving of pilot fuel. Compared to singlefuel mode, there was 25-32 % reduction in system and brake thermal efficiency along with significantly lower NOx, higher CO and CO2 emissions when the bio-electricity generating system was operated in dual fuel mode. Overall, the developed system could produce electricity successfully by completely uti- lising Jatropha seeds without leaving any seed cake to cause environmental pollution.

  4. HDR reservoir flow impedance and potentials for impedance reduction

    Energy Technology Data Exchange (ETDEWEB)

    DuTeau, R.; Brown, D.

    1993-06-01

    The data from flow tests which employed two different production zones in a well at Fenton Hill indicates the flow impedance of a wellbore zone damaged by rapid depressurization was altered, possibly by pressure spallation, which appears to have mechanically propped the joint apertures of outlet flow paths intersecting the altered wellbore. The rapid depressurization and subsequent flow test data derived from the damaged well has led to the hypothesis that pressure spallation and the resultant mechanical propping of outlet flow paths reduced the outlet flow impedance of the damaged wellbore. Furthermore, transient pressure data shows the largest pressure drop between the injection and production wellheads occurs near the production wellbore, so lowering the outlet impedance by increasing the apertures of outlet flow paths will have the greatest effect on reducing the overall reservoir impedance. Fenton Hill data also reveals that increasing the overall reservoir pressure dilates the apertures of flow paths, which likewise serves to reduce the reservoir impedance. Data suggests that either pressure dilating the wellbore connected joints with high production wellhead pressure, or mechanically propping open the outlet flow paths will increase the near-wellbore permeability. Finally, a new method for calculating and comparing near-wellbore outlet impedances has been developed. Further modeling, experimentation, and engineered reservoir modifications, such as pressure dilation and mechanical propping, hold considerable potential for significantly improving the productivity of HDR reservoirs.

  5. A current-excited triple-time-voltage oversampling method for bio-impedance model for cost-efficient circuit system.

    Science.gov (United States)

    Yan Hong; Yong Wang; Wang Ling Goh; Yuan Gao; Lei Yao

    2015-08-01

    This paper presents a mathematic method and a cost-efficient circuit to measure the value of each component of the bio-impedance model at electrode-electrolyte interface. The proposed current excited triple-time-voltage oversampling (TTVO) method deduces the component values by solving triple simultaneous electric equation (TSEE) at different time nodes during a current excitation, which are the voltage functions of time. The proposed triple simultaneous electric equations (TSEEs) allows random selections of the time nodes, hence numerous solutions can be obtained during a single current excitation. Following that, the oversampling approach is engaged by averaging all solutions of multiple TSEEs acquired after a single current excitation, which increases the practical measurement accuracy through the improvement of the signal-to-noise ratio (SNR). In addition, a print circuit board (PCB) that consists a switched current exciter and an analog-to-digital converter (ADC) is designed for signal acquisition. This presents a great cost reduction when compared against other instrument-based measurement data reported [1]. Through testing, the measured values of this work is proven to be in superb agreements on the true component values of the electrode-electrolyte interface model. This work is most suited and also useful for biological and biomedical applications, to perform tasks such as stimulations, recordings, impedance characterizations, etc.

  6. Heterogeneous silicon mesostructures for lipid-supported bioelectric interfaces

    Energy Technology Data Exchange (ETDEWEB)

    Jiang, Yuanwen; Carvalho-de-Souza, João L.; Wong, Raymond C. S.; Luo, Zhiqiang; Isheim, Dieter; Zuo, Xiaobing; Nicholls, Alan W.; Jung, Il Woong; Yue, Jiping; Liu, Di-Jia; Wang, Yucai; De Andrade, Vincent; Xiao, Xianghui; Navrazhnykh, Luizetta; Weiss, Dara E.; Wu, Xiaoyang; Seidman, David N.; Bezanilla, Francisco; Tian, Bozhi

    2016-06-27

    Silicon-based materials have widespread application as biophysical tools and biomedical devices. Here we introduce a biocompatible and degradable mesostructured form of silicon with multi-scale structural and chemical heterogeneities. The material was synthesized using mesoporous silica as a template through a chemical vapour deposition process. It has an amorphous atomic structure, an ordered nanowire-based framework and random submicrometre voids, and shows an average Young’s modulus that is 2–3 orders of magnitude smaller than that of single-crystalline silicon. In addition, we used the heterogeneous silicon mesostructures to design a lipid-bilayer-supported bioelectric interface that is remotely controlled and temporally transient, and that permits non-genetic and subcellular optical modulation of the electrophysiology dynamics in single dorsal root ganglia neurons. Our findings suggest that the biomimetic expansion of silicon into heterogeneous and deformable forms can open up opportunities in extracellular biomaterial or bioelectric systems.

  7. NOVEL DESIGN OF A BIOELECTRIC AMPLIFIER WITH MINIMIZED MAGNITUDE AND PHASE ERRORS

    Institute of Scientific and Technical Information of China (English)

    Mashhour Bani Amer; Assistant Professor

    2001-01-01

    A new design of a bioelectric amplifier that has better parameters than conventional designs is presented. The design allows the construction of bioelectric amplifier with improved parameters in terms of common-mode rejection ratio and phase and magnitude errors. The voltage gain is easily adapted to a wide range of biomedical applications. The experimental and simulation results of the designed bioelectric amplifier are also included.

  8. NEUROFEEDBACK INFLUENCE ON CEREBRUM BIOELECTRICAL ACTIVITY IN GYMNASTS-WOMEN

    Directory of Open Access Journals (Sweden)

    T. Yu. Strizhkova

    2013-01-01

    Full Text Available The analysis of electroencephalogram (EEG of highly skilled gymnasts-women (main group – 49, control group – 39 showed the availability of cerebrum bioelectrical activity features of sportswomen connected with left hemisphere dominance, predominance of theta-rhythm power and lower reaction to eyes closing, also character of neurodynamic changes generated by neurofeedback course depended on ovarian-menstrual cycle phases.

  9. [Effect of dosed diet restriction on physiological remodeling and bioelectric properties of bone].

    Science.gov (United States)

    Levashov, M I; Ianko, R V; Chaka, E G; Safonov, S L

    2014-07-01

    The effect of dosed diet restriction on the physiological remodeling and bioelectric properties of bone tissue was studied in 48 male Wistar rats 3- and 18-months of age. The rate of bone tissue apposition was studied by the dynamic histomorphometry method (intravital tetracycline labeling). Electric potentials on the periosteal surface of the freshly isolated femurs were recorded. The magnitude of dielectric loss factor was determined to assess the quality of bone tissue. The control rats received a standard diet. The experimental rats received a limited diet (60 % of the standard mass) for 28 days. The magnitude and rate of the bone tissue apposition on the endosteal and periosteal surface of the tibia were less by 38.4% and 122.7% respectively in experimental rats after dosed diet restriction. Electric potential in the metaphyseal-epiphyseal growth zones of the femur was 29.7% lower, and the dielectric loss factor increased by 15.8%. The bone tissue apposition rate and the electric potential magnitude were increased 10 days after completion of the dosed diet restriction. The magnitude of the dielectric loss factor decreased after returning to the standard diet. Key words: dosed diet restriction, bone, remodelling, bioelectric properties.

  10. [Endocrine obesity: bioelectric profiles (biotypes) detected in the body composition].

    Science.gov (United States)

    Miggiano, G A D; Petitti, T

    2004-09-01

    136 patients were selected (16 men and 120 women with non-specific menstrual disturbances) with a BMI (Body Mass Index) between 25 and 45 kg/m2, which were diagnosed with "disendocrinia" (GH deficit, hyperadrenocorticism, hypothyroidsm, hyperandrogenism, menstrual cycle disorders). The proposed approach, based on the visualization of the value distribution of the electric measures in different graphics, is able to immediately explain the bioelectric state of the individual's lean-mass. Subjects with hypothyroidism present, along with their overweight, less bio-conducting mass, with an altered fluid intra/extra-cellular distribution. Patients with hyperadrenocorticism show instead an hyperhydratation of the body mass, especially in the extracellular level. Patients with menstrual disorders (amenorrea, polycystic ovary syndrome, anovulatory cycle etc...) present a lean mass reduction (elevated Rs) and an increase of the intra-cellular compartment (elevated-Xc). Patients with hyper-androgenism (and hirsutism) show a characteristic bioelectric "pattern", with low Rs levels and high Xc levels. Subjects with GH deficit (men and women), has a trend of documenting bioelectric measures with lower lean mass and higher fat-mass. Different electric biotypes seem to characterize the body composition in the several endocrine disorders.

  11. Photoelectrode thin film of dye-sensitized solar cell fabricated by anodizing method and spin coating and electrochemical impedance properties of DSSC

    Energy Technology Data Exchange (ETDEWEB)

    Chang, Ho, E-mail: f10381@ntut.edu.tw [Graduate Institute of Manufacturing Technology, National Taipei University of Technology, Taipei 10608, Taiwan (China); Chen, Chih-Hao [Department of Thoracic Surgery, Mackay Memorial Hospital, Taipei 10419, Taiwan (China); Graduate Institute of Mechanical and Electrical Engineering, National Taipei University of Technology, Taipei 10608, Taiwan (China); Kao, Mu-Jung [Department of Vehicle Engineering, National Taipei University of Technology, Taipei 10608, Taiwan (China); Chien, Shu-Hua [Institute of Chemistry, Academia Sinica, Taipei 115, Taiwan (China); Chou, Cheng-Yi [Graduate Institute of Manufacturing Technology, National Taipei University of Technology, Taipei 10608, Taiwan (China)

    2013-06-15

    The paper studies the photoelectrode thin film of dye-sensitized solar cell (DSSC) fabricated by anodizing method, explores the structure and properties of the fabricated photoelectrode thin film, measures the photoelectric conversion efficiency of DSSC, and finds the electrochemical impedance properties of DSSCs assembled by photoelectrode thin films in different thicknesses. Besides, in order to increase the specific surface area of nanotubes, this paper deposits TiO{sub 2} nanoparticles (TNP) on the surface of titanium oxide nanotube (TNT). As shown in experimental results, the photoelectric conversion efficiency of the DSSC fabricated by the study rises to 6.5% from the original 5.43% without TnB treatment, with an increase of photoelectric conversion efficiency by 19.7%. In addition, when the photoelectrode thin film is fabricated with mixture of TNTs and TNP in an optimal proportion of 2:8 and the photoelectrode thin film thickness is 15.5 μm, the photoelectric conversion efficiency can reach 7.4%, with an increase of 36.7% from the original photoelectric conversion efficiency at 5.43%. Besides, as found in the results of electrochemical impedance analysis, the DSSC with photoelectrode thin film thickness at 15.5 μm has the lowest charge-conduction resistance (R{sub k}) value 9.276 Ω of recombined electron and conduction resistance (R{sub w}) value 3.25 Ω of electrons in TiO{sub 2}.

  12. Transfer impedance simulation and measurement methods to analyse shielding behaviour of HV cables used in Electric-Vehicles and Hybrid-Electric-Vehicles

    Science.gov (United States)

    Mushtaq, Abid; Frei, Stephan

    2016-09-01

    In the power drive system of the Electric Vehicles (EVs) and Hybrid Electric Vehicles (HEVs), High Voltage (HV) cables play a major role in evaluating the EMI of the whole system. Transfer impedance (ZT) is the most commonly used performance parameter for the HV cable. To analyse and design HV cables and connectors with better shielding effectiveness (SE), appropriate measurement and simulation methods are required. In this paper, Ground Plate Method (GPM) with improvements has been proposed to measure ZT. Use of low-frequency ferrites to avoid ground-loop effects has also been investigated. Additionally, a combination of analytical model with a circuit model has been implemented to simulate limitations (frequency response) of the test setup. Also parametrical studies using the analytical model have been performed to analyse the shielding behaviour of HV cables.

  13. Pulse Wave Velocity and Cardiac Output vs. Heart Rate in Patients with an Implanted Pacemaker Based on Electric Impedance Method Measurement

    Science.gov (United States)

    Soukup, Ladislav; Vondra, Vlastimil; Viščor, Ivo; Jurák, Pavel; Halámek, Josef

    2013-04-01

    The methods and device for estimation of cardiac output and measurement of pulse wave velocity simultaneously is presented here. The beat-to-beat cardiac output as well as pulse wave velocity measurement is based on application of electrical impedance method on the thorax and calf. The results are demonstrated in a study of 24 subjects. The dependence of pulse wave velocity and cardiac output on heart rate during rest in patients with an implanted pacemaker was evaluated. The heart rate was changed by pacemaker programming while neither exercise nor drugs were applied. The most important result is that the pulse wave velocity, cardiac output and blood pressure do not depend significantly on heart rate, while the stroke volume is reciprocal proportionally to the heart rate.

  14. Use of electrical impedance spectroscopy as a practical method of investigating the formation of aggregates in aqueous solutions of dyes and surfactants.

    Science.gov (United States)

    de Oliveira, Helinando P; de Melo, Celso P

    2011-06-01

    Molecular aggregation plays a key role in the physicochemical properties of dyes and surfactants. In this work, we show that electrical impedance spectroscopy (EIS) provides a practical method for the investigation of processes such as micellization in surfactants and dye dimerization. The electrical characterization of the structural phase transitions associated with aggregation events in these systems allows an accurate and direct determination of relevant parameters such as the corresponding critical concentrations for micelle formation and dimerization of these types of molecules, without the need of recurring to the use of auxiliary probe or reporter molecules. Because of its competitive advantages with respect to currently used methods (such as conductimetry and spectroscopic techniques), we argue that when implemented along the procedures described in this work, EIS becomes a simple and convenient technique for the characterization of aggregation processes in soft matter.

  15. Research progress in the impedance method in the detection of microorganisms in food%阻抗法检测食品中微生物的研究进展

    Institute of Scientific and Technical Information of China (English)

    张爱萍; 唐佳妮; 刘东红

    2011-01-01

    As a rapid detection method of microorganisms,the impedance method can be used to rapidly detect the total number of colonies, coliform, mold, yeast, and so on.There is great prospect for the rapid detection of pathogens in food as the research of the impedance method developed.The development of the traditional impedance method and the latest research of the impedance method were reviewed ,aimed at the future research of the impedance method for rapid detection of microorganisms in food.%阻抗法作为微生物快速检测方法,可用于食品中菌落总数、大肠菌群、霉菌、酵母等常规微生物的快速检测;随着研究的深入,其在食品病原菌快速检测中也大有前景.综述了传统阻抗微生物检测的发展历程及阻抗法最新研究方向,旨在为今后阻抗法快速检测食品中微生物的研究奠定基础.

  16. Detection of electrical properties of soybean milk based on AC impedance method%基于交流阻抗法的豆浆电特性检测

    Institute of Scientific and Technical Information of China (English)

    宋华鲁; 闫银发; 宋占华; 陈晨; 李法德

    2015-01-01

    in the impedance of the soybean milk with the frequency, combining with the equivalent circuit model, it was concluded that the frequency of the power for ohmic heating should be in the range from 300 Hz to 300 kHz. The experimental results also showed that the equivalent resistance (R) of soybean milk decreased with the increase in the temperature and the solids content, respectively. By the regression analysis on the data, it was found that the relationship between the equivalent resistance (R) and the temperature could be described by a negative exponential function (the coefficient of determination R2 was 0.996 at the solid content of 9.58%, P<0.01), the relationship between the equivalent resistance (R) and the solid content could be also described by a negative exponential function (the coefficient of determination R2 was 0.992 at 40 °C, P<0.01). The value of Q (one of the parameters for describing the CPE) decreased with the increase in temperature;however, if the solid content of soybean milk was more than 3.5%, the value of Q increased sharply. The value of n (the other parameter for describing the CPE) increased with the increase in temperature, but it did not changed significantly with the solid content (ranged from 1.01%to 9.58%). The results in this research should be taken as a reference for selecting the frequency of the power for designing an ohmic heating system. In addition, the results also founded a method for detecting rapidly soybean milk quality on the analysis of electric parameters of soybean milk.%为实现豆浆品质快速检测和通电加热电源频率的优化,该文利用精密阻抗分析仪和DJS-10电导电极通过50 mV的激励电压在20 Hz~12 MHz频率范围内测量了不同温度(30~85℃)和不同固形物含量(1.01%~9.58%)的豆浆的交流阻抗。试验结果表明,豆浆阻抗模值与阻抗相位角随测量频率变化具有明显规律。豆浆的阻抗特性与温度以及固形物

  17. Techniques of body composition assessment: a review of laboratory and field methods.

    Science.gov (United States)

    Wagner, D R; Heyward, V H

    1999-06-01

    Body composition is one of the major health-related components of fitness. Thus, it is important for health and fitness professionals to have a general understanding of the most commonly used techniques for assessing body composition. This review presents the developmental background and underlying principles and theory of four laboratory (hydrodensitometry, air displacement plethysmography, isotope dilution, and dual-energy x-ray absorptiometry) and four field (bioelectrical impedance analysis, near-infrared interactance, skinfolds, and anthropometry) methods of body composition assessment. In addition to a description of the methods, the validity, and reliability, strengths, and limitations of each measurement tool are examined. Highlights of the laboratory methods include the relatively new Bod Pod air displacement device, which is a promising assessment tool more convenient than hydrodensitometry but still lacking substantial validity testing and the ability of dual-energy x-ray absorptiometry to measure regional composition making it an attractive method for clinicians. Advancements in segmental and multifrequency bioelectrical impedance for compartmental analysis have enhanced the value of this field method, but research continues to show that commercially available near-infrared interactance units are invalid. With this knowledge, the clinician and researcher should be able to make an informed decision regarding the most appropriate measurement device for their body composition assessments.

  18. A short tutorial contribution to impedance and AC-electrokinetic characterization and manipulation of cells and media: Are electric methods more versatile than acoustic and laser methods?

    Directory of Open Access Journals (Sweden)

    Jan Gimsa

    2014-11-01

    Full Text Available Lab-on-chip systems (LOCs can be used as in vitro systems for cell culture or manipulation in order to analyze or monitor physiological cell parameters. LOCs may combine microfluidic structures with integrated elements such as piezo-transducers, optical tweezers or electrodes for AC-electrokinetic cell and media manipulations. The wide frequency band (<1 kHz to >1 GHz usable for AC-electrokinetic manipulation and characterization permits avoiding electrochemical electrode processes, undesired cell damage, and provides a choice between different polarization effects that permit a high electric contrast between the cells and the external medium as well as the differentiation between cellular subpopulations according to a variety of parameters. It has been shown that structural polarization effects do not only determine the impedance of cell suspensions and the force effects in AC-electrokinetics but can also be used for the manipulation of media with inhomogeneous temperature distributions. This manuscript considers the interrelations of the impedance of suspensions of cells and AC-electrokinetic single cell effects, such as electroorientation, electrodeformation, dielectrophoresis, electrorotation, and travelling wave (TW dielectrophoresis. Unified models have allowed us to derive new characteristic equations for the impedance of a suspension of spherical cells, TW dielectrophoresis, and TW pumping. A critical review of the working principles of electro-osmotic, TW and electrothermal micropumps shows the superiority of the electrothermal pumps. Finally, examples are shown for LOC elements that can be produced as metallic structures on glass chips, which may form the bottom plate for self-sealing microfluidic systems. The structures can be used for cell characterization and manipulation but also to realize micropumps or sensors for pH, metabolites, cell-adhesion, etc.

  19. An impedance analyzer method to simulate the oscillating characteristic of a series piezoelectric sensor in oscillators with zero or non-zero phases.

    Science.gov (United States)

    Dazhong, S; Yuanjin, X; Lihua, N; Shouzhuo, Y

    1994-11-01

    An impedance analyzer method is employed to simulate the oscillation frequency of a series piezoelectric quartz crystal (SPQC) in electrolyte or non-electrolyte solutions. The influence of the oscillator phase on the oscillation frequency and response sensitivity are theoretically derived and experimentally verified. In non-electrolyte liquids, the oscillator phase has little effect on both the oscillation frequency and the response to the permittivity. But in electrolyte solutions, the oscillator phase has a significant influence on the oscillation frequency and the response sensitivity to the conductivity. Depending on the oscillator phase, the oscillation frequency of the SPQC may increase, be maintained or decrease with increasing conductivity in low or high conductive solutions. The dependence of the oscillation frequency of the SPQC on the supply voltage is explained. As an example of the applications, the SPQC is applied to the determination of the critical micelle concentration of ionic surfactants in aqueous solutions.

  20. Definition of the characteristic impedance

    Institute of Scientific and Technical Information of China (English)

    徐云生; Abbas Sayed OMAR

    1996-01-01

    Currently available definitions of the characteristic impedance are ambiguous andior inaccurate.A general definition,based on the description of discontinuities between adjacent waveguides,is given.This definition is accurate and independent of the structure concerned.So it can be applied to the design of passive components in any type of transmission lines.Using this definition,a given structure can be uniquely characterized,but the absolute value of the characteristic impedance has no sense any more.As an example,the design of a microstrip impedance transformer using this new definition is presented.Numerical results using the mode-matching method prove the accuracy of the theory.

  1. [Evaluation of nutritional Status in lung cancer using bio electrical impedance analysis and mini nutritional assessment].

    Science.gov (United States)

    Daghfous, Hafaoua; El Ayeb, Wejdène; Alouane, Leila; Tritar, Fatma

    2014-12-01

    Malnutrition and cachexia were a frequent problem in lung cancer and increases the risks of morbidity and mortality in these patients. Bioelectrical impedance analysis (BIA) is easy, non-invasive and reproducible method that can be performed. Evaluate nutritional status in patients with primary lung cancer by Mini Nutritional Assessment (MNA), BIA and anthropometric values (weight, arm and calf circumferences) and correlate the nutritional parameters to severity of cancer and histopathology. The nutritional status of 73 cases of primary lung cancer was evaluated by anthropometric parameters, MNA test and impedencemetrie Results: According to body mass index (BMI), malnutrition, overweight and obesity were noted in 34,2%, 13,7% and 5,5%. According to BMI, free-fat mass index (FFMI) and fat mass index (FMI), the investigations occurred malnutrition and depletion of muscle in respectively 19,2% and 23,3% of cases. Fat depletion was noted in 21,9%. Overweight and obesity were detected in 6,8% and 5,5% of cases. Assessment by MNA, revealed that 28,7% of patients were already malnourished and 49,3% of patients were at risk of malnutrition. A significant correlation existed between the score of MNA and arm and calf circumferences, FFMI and FMI. FMI was significantly lower in group of patients with small lung carcinoma. Only FFMI allows early detection of malnutrition in cancer patients overestimated by measuring BMI and arm circumference was the better indicator of depletion of muscle.

  2. REVIEW: A review of in vivo experimental methods to determine the composition of the human body

    Science.gov (United States)

    Sutcliffe, J. F.

    1996-05-01

    This review of experimental methods employed in the measurement of the composition of the human body covers the developments that have occurred over the past 30 years. Early methods such as hydrodensitometry and skinfold anthropometry have been superseded by dual-energy x-ray absorptiometry and bioelectrical impedance spectroscopy. The measurement of the whole-body abundance of certain elements by isotopic dilution, neutron activation analysis and x-ray fluorescence can give important information of clinical significance, but neutron activation facilities remain available in only a few centres worldwide. The relatively simple, rapid and risk-free electrical methods such as multifrequency bioelectrical impedance analysis, which can be employed at the bedside, have been found to be more complicated in their interpretation. Electromagnetic methods may only measure the composition of the human body at its surface. X-ray computed tomography and magnetic resonance imaging have not yet been employed much in body composition measurements. Some models for the composition of the human body are reviewed.

  3. Adductor pollicis muscle and hand grip strength: potential methods of nutritional assessment in outpatients with stroke

    Directory of Open Access Journals (Sweden)

    Débora Rocha Oliveira

    2010-12-01

    Full Text Available Objective: To evaluate and compare the effectiveness of different methods used for nutritional assessment of outpatients who had hemiplegic stroke. Methods: A cross-section study with adult and elderly patients of both genders enrolled in a rehabilitation center. The analyzed variables were anthropometric measurements, bioelectrical impedance, hand grip strength and thickness of the adductor pollicis muscle. The Pearson χ2 test was used to check the association between variables with a significance level of α = 5%. Results: When evaluating the association between indicators of muscle mass, it was observed that the hand grip strength in both genders was positively correlated with arm muscle circumference (p = 0.0196 and lean mass (p = 0.0002. Fat mass measured by the bioelectrical impedance method already showed a significant inverse relationship with the grip (r = -0.3879. The thickness of the adductor pollicis muscle showed significant association with lean mass (p = 0.0052 and hand grip (p = 0.0024. Conclusion: In this study, the hand grip strength and thickness of the adductor pollicis muscle were well correlated with measurements determined by anthropometry and bioimpedance. The results show the applicability of grip strength and thickness of the adductor pollicis muscle in clinical practice as nutritional assessment methods for this population, especially elderly patients, since they detect functional changes not captured by other parameters in the short term and are important for early identification of risk nutrition.

  4. A better method to define electrical chargeability from laboratory measurements of spectral impedance using a parallel Cole-Cole equivalent circuit

    Science.gov (United States)

    Enkin, R. J.

    2014-12-01

    Induced polarization (IP) is a successful electric method to identify drill targets for mineral exploration at the property scale. The Paleomagnetism and Petrophysics Laboratory at the Geological Survey of Canada makes petrophysical measurements on cylindrical rock samples, 2.5 cm diameter and 2.2 cm long. This small size has advantages, including allowing measurement of magnetic remanence with standard paleomagnetism equipment, but it is too small to allow a 4-contact electrical impedance measurement. The samples are impregnated with distilled water under vacuum and allowed 24 hours for solutes to dissolve off pore walls, in order to approximate original groundwater ionic conductivity. We use graphite electrodes on the flat surfaces and measure the complex impedance at 5 frequencies per decade from 1 MHz down to 25 mHz. Typical responses on a Cole-Cole plot (i.e., real vs. imaginary components displayed parametrically as a function of frequency) look like a two overlapping circular arcs followed by a constant-phase diffusive response at lowest frequencies. The impedance frequency response is fit with a circuit in which the rock is modelled as a set of parallel resistor and constant-phase-element pathways, connected in series through a modified constant-phase-element representing the low frequency sample-holder response. The program "ZarcFit", written in LabView, allows the operator to tune parameters of an equivalent but far more intuitive series circuit with a set of 13 sliders, and then perform a least-squares optimization. Time domain chargeability is defined by removing the effect of the sample holder, taking the Fourier transform to convert the frequency response to its time-domain equivalent and then integrating under the resulting voltage-decay curve. Time domain measurements using two-electrode sample holders are necessarily contaminated by the low-frequency response of ionic diffusion at the electrodes. Results are compiled in the Canadian Rock Physical

  5. An integral equation method for calculating sound field diffracted by a rigid barrier on an impedance ground.

    Science.gov (United States)

    Zhao, Sipei; Qiu, Xiaojun; Cheng, Jianchun

    2015-09-01

    This paper proposes a different method for calculating a sound field diffracted by a rigid barrier based on the integral equation method, where a virtual boundary is assumed above the rigid barrier to divide the whole space into two subspaces. Based on the Kirchhoff-Helmholtz equation, the sound field in each subspace is determined with the source inside and the boundary conditions on the surface, and then the diffracted sound field is obtained by using the continuation conditions on the virtual boundary. Simulations are carried out to verify the feasibility of the proposed method. Compared to the MacDonald method and other existing methods, the proposed method is a rigorous solution for whole space and is also much easier to understand.

  6. Bioelectrical signal processing in cardiac and neurological applications and electromyography: physiology, engineering, and noninvasive applications

    Directory of Open Access Journals (Sweden)

    Valentinuzzi Max E

    2007-07-01

    Full Text Available Abstract The present article reviews two recent books dealing with rather closely related subjects; in fact, they tend to complement and supplement reciprocally. Obviously, the electromyogram is a bioelectrical signal that often is mathematically manipulated in different ways to better extract its information. Moreover, its correlation with other bioelectric variables may become necessary.

  7. Impedance plethysmography of thoracic region: impedance cardiography.

    Directory of Open Access Journals (Sweden)

    Deshpande A

    1990-10-01

    Full Text Available Impedance plethysmograms were recorded from thoracic region in 254 normal subjects, 183 patients with coronary artery disease, 391 patients with valvular heart disease and 107 patients with congenital septal disorder. The data in 18 normal subjects and 55 patients showed that basal impedance decreases markedly during exercise in patients with ischaemic heart disease. Estimation of cardiac index by this technique in a group of 99 normal subjects has been observed to be more consistent than that of the stroke volume. Estimation of systolic time index from impedance plethysmograms in 34 normal subjects has been shown to be as reliable as that from electrocardiogram, phonocardiogram and carotid pulse tracing. Changes in the shape of plethysmographic waveform produced by valvular and congenital heart diseases are briefly described and the role of this technique in screening cardiac patients has been highlighted.

  8. Mapping small intestine bioelectrical activity using high-resolution printed-circuit-board electrodes.

    Science.gov (United States)

    Angeli, Timothy R; O'Grady, Gregory; Erickson, Jonathan C; Du, Peng; Paskaranandavadivel, Niranchan; Bissett, Ian P; Cheng, Leo K; Pullan, Andrew J

    2011-01-01

    In this study, novel methods were developed for the in-vivo high-resolution recording and analysis of small intestine bioelectrical activity, using flexible printed-circuit-board (PCB) electrode arrays. Up to 256 simultaneous recordings were made at multiple locations along the porcine small intestine. Data analysis was automated through the application and tuning of the Falling-Edge Variable-Threshold algorithm, achieving 92% sensitivity and a 94% positive-predictive value. Slow wave propagation patterns were visualized through the automated generation of animations and isochronal maps. The methods developed and validated in this study are applicable for use in humans, where future studies will serve to improve the clinical understanding of small intestine motility in health and disease.

  9. Tracking of electrochemical impedance of batteries

    Science.gov (United States)

    Piret, H.; Granjon, P.; Guillet, N.; Cattin, V.

    2016-04-01

    This paper presents an evolutionary battery impedance estimation method, which can be easily embedded in vehicles or nomad devices. The proposed method not only allows an accurate frequency impedance estimation, but also a tracking of its temporal evolution contrary to classical electrochemical impedance spectroscopy methods. Taking into account constraints of cost and complexity, we propose to use the existing electronics of current control to perform a frequency evolutionary estimation of the electrochemical impedance. The developed method uses a simple wideband input signal, and relies on a recursive local average of Fourier transforms. The averaging is controlled by a single parameter, managing a trade-off between tracking and estimation performance. This normalized parameter allows to correctly adapt the behavior of the proposed estimator to the variations of the impedance. The advantage of the proposed method is twofold: the method is easy to embed into a simple electronic circuit, and the battery impedance estimator is evolutionary. The ability of the method to monitor the impedance over time is demonstrated on a simulator, and on a real Lithium ion battery, on which a repeatability study is carried out. The experiments reveal good tracking results, and estimation performance as accurate as the usual laboratory approaches.

  10. Bioelectricity production from various wastewaters through microbial fuel cell technology

    Directory of Open Access Journals (Sweden)

    Abhilasha S Mathuriya

    2009-12-01

    Full Text Available Microbial fuel cell technology is a new type of renewable and sustainable technology for electricity generation since it recovers energy from renewable materials that can be difficult to dispose of, such as organic wastes and wastewaters. In the present contribution we demonstrated electricity production by beer brewery wastewater, sugar industry wastewater, dairy wastewater, municipal wastewater and paper industry wastewater. Up to 14.92 mA current and 90.23% COD removal was achieved in 10 days of operation. Keywords: Bioelectricity, COD, Microbial Fuel Cells, Wastewater Received: 12 November 2009 / Received in revised form: 30 November 2009, Accepted: 30 November 2009, Published online: 10 March 2010

  11. Bio-isolated dc operational amplifier. [for bioelectric measurements

    Science.gov (United States)

    Lee, R. D. (Inventor)

    1974-01-01

    A bio-isolated dc operational amplifier is described for use in making bioelectrical measurements of a patient while providing isolation of the patient from electrical shocks. The circuit contains a first operational amplifier coupled to the patient with its output coupled in a forward loop through a first optic coupler to a second operational amplifier. The output of the second operational amplifier is coupled to suitable monitoring circuitry via a feedback circuit including a second optic coupler to the input of the first operational amplifier.

  12. Fractional Order Element Based Impedance Matching

    KAUST Repository

    Radwan, Ahmed Gomaa

    2014-06-24

    Disclosed are various embodiments of methods and systems related to fractional order element based impedance matching. In one embodiment, a method includes aligning a traditional Smith chart (|.alpha.|=1) with a fractional order Smith chart (|.alpha.|.noteq.1). A load impedance is located on the traditional Smith chart and projected onto the fractional order Smith chart. A fractional order matching element is determined by transitioning along a matching circle of the fractional order Smith chart based at least in part upon characteristic line impedance. In another embodiment, a system includes a fractional order impedance matching application executed in a computing device. The fractional order impedance matching application includes logic that obtains a first set of Smith chart coordinates at a first order, determines a second set of Smith chart coordinates at a second order, and determines a fractional order matching element from the second set of Smith chart coordinates.

  13. Impedance-Based Non-Destructive Testing Method Combined with Unmanned Aerial Vehicle for Structural Health Monitoring of Civil Infrastructures

    Directory of Open Access Journals (Sweden)

    Wongi S Na

    2016-12-01

    Full Text Available Unmanned aerial vehicles (UAVs, commonly known as drones, are a rising topic in remote sensing technologies for structural health monitoring. With technology advancement in cameras, the visual inspection method using drones is gaining much attention in the field of civil engineering. However, although visual inspection methods are feasible for finding cracks in structures, the limitations of image processing for finding internal damage or small defects cannot be ignored. To overcome this problem, a possible application concept of UAV, combined with a vibration-based non-destructive health monitoring method, is proposed. The idea is for the drone to temporarily attach the piezoelectric transducer onto a specific region where excitation and data acquisition occurs simultaneously. This eliminates the need for a structure to be covered with hundreds of sensors for monitoring, as this concept uses a single piezoelectric transducer for monitoring a structure. The proposed work offers new areas of research by converging UAV with a vibration-based method, as associated problems are required to be solved.

  14. An impedance grasping strategy

    NARCIS (Netherlands)

    Muñoz Arias, Mauricio; Scherpen, Jacqueline M.A.; Macchelli, Alessandro

    2014-01-01

    This work is devoted to an impedance grasping strategy for a class of standard mechanical systems in the port- Hamiltonian framework. The presented control strategy re- quires a set of coordinate transformations, since the impedance control in the port-Hamiltonian framework with structure preservati

  15. Thermal conductivity of Gd{sub 2}Zr{sub 2}O{sub 7} thin films using thermal-impedance method

    Energy Technology Data Exchange (ETDEWEB)

    Kim, J.W. [Department of Mechanical Engineering, Pusan National University, Busan 609-735 (Korea, Republic of); Jeong, G.E. [Department of Physics, Pusan National University, Busan 609-735 (Korea, Republic of); Yang, Ho-Soon [Department of Mechanical Engineering, Pusan National University, Busan 609-735 (Korea, Republic of); Department of Physics, Pusan National University, Busan 609-735 (Korea, Republic of)

    2011-05-15

    Pyrochlore-structured rare-earth materials have been of interest recently as thermal-barrier coating materials because they show low thermal conductivity due to the oxygen vacancy. This study reports the preparation and thermal characterization of Gd{sub 2}Zr{sub 2}O{sub 7} films deposited on YSZ and Al{sub 2}O{sub 3} substrates. Since the thermal properties of Gd{sub 2}Zr{sub 2}O{sub 7} and YSZ are not obviously different, the thermal-impedance method (the extended 3{omega} method) is used to study the films in this work. Gd{sub 2}Zr{sub 2}O{sub 7} thin films of various thicknesses are deposited using a pulsed laser deposition method. The thermal conductivity of Gd{sub 2}Zr{sub 2}O{sub 7} thin films exhibits a dependence on film thickness. The thickness-dependent thermal conductivity is ascribed to the interfacial thermal resistance between the Gd{sub 2}Zr{sub 2}O{sub 7} film and substrates. The interfacial resistance is obtained by fitting the thickness-dependent thermal conductivity with the effective thermal-conductivity equation. (Copyright copyright 2011 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim)

  16. Rotor damage detection by using piezoelectric impedance

    Science.gov (United States)

    Qin, Y.; Tao, Y.; Mao, Y. F.

    2016-04-01

    Rotor is a core component of rotary machinery. Once the rotor has the damage, it may lead to a major accident. Thus the quantitative rotor damage detection method based on piezoelectric impedance is studied in this paper. With the governing equation of piezoelectric transducer (PZT) in a cylindrical coordinate, the displacement along the radius direction is derived. The charge of PZT is calculated by the electric displacement. Then, by the use of the obtained displacement and charge, an analytic piezoelectric impedance model of the rotor is built. Given the circular boundary condition of a rotor, annular elements are used as the analyzed objects and spectral element method is used to set up the damage detection model. The Electro-Mechanical (E/M) coupled impedance expression of an undamaged rotor is deduced with the application of a low-cost impedance test circuit. A Taylor expansion method is used to obtain the approximate E/M coupled impedance expression for the damaged rotor. After obtaining the difference between the undamaged and damaged rotor impedance, a rotor damage detection method is proposed. This method can directly calculate the change of bending stiffness of the structural elements, it follows that the rotor damage can be effectively detected. Finally, a preset damage configuration is used for the numerical simulation. The result shows that the quantitative damage detection algorithm based on spectral element method and piezoelectric impedance proposed in this paper can identify the location and the severity of the damaged rotor accurately.

  17. Optimization of enhanced bioelectrical reactor with electricity from microbial fuel cells for groundwater nitrate removal.

    Science.gov (United States)

    Liu, Ye; Zhang, Baogang; Tian, Caixing; Feng, Chuanping; Wang, Zhijun; Cheng, Ming; Hu, Weiwu

    2016-01-01

    Factors influencing the performance of a continual-flow bioelectrical reactor (BER) intensified by microbial fuel cells for groundwater nitrate removal, including nitrate load, carbon source and hydraulic retention time (HRT), were investigated and optimized by response surface methodology (RSM). With the target of maximum nitrate removal and minimum intermediates accumulation, nitrate load (for nitrogen) of 60.70 mg/L, chemical oxygen demand (COD) of 849.55 mg/L and HRT of 3.92 h for the BER were performed. COD was the dominant factor influencing performance of the system. Experimental results indicated the undistorted simulation and reliable optimized values. These demonstrate that RSM is an effective method to evaluate and optimize the nitrate-reducing performance of the present system and can guide mathematical models development to further promote its practical applications.

  18. Electrochemical decolorization of methyl orange powered by bioelectricity from single-chamber microbial fuel cells.

    Science.gov (United States)

    Zhang, Baogang; Wang, Zhijun; Zhou, Xiang; Shi, Chunhong; Guo, Huaming; Feng, Chuanping

    2015-04-01

    Methyl orange (MO), a typical azo dye, is a well-known recalcitrant pollutant in dye wastewater. An aeration electrochemical system with single-chamber microbial fuel cell (MFC) as renewable power sources is proposed for MO decolorization. The enhanced color removal efficiency up to 90.4% within 360 min is observed with voltage across the aeration electrolytic reactor fixed at 700 mV. The results from gas chromatography-mass spectrometry (GC-MS) analysis indicate the destruction of MO, with generation of low molecular weight compounds such as benzene derivatives. Comparison experiments imply the indirect electrochemical oxidation of MO by generated H2O2 is mainly responsible for MO decolorization in present study. This work offers a cost-effective electrochemical method for enhancing electrochemical degradation of dyes with bioelectricity generated from MFCs.

  19. Spontaneous arsenic (III) oxidation with bioelectricity generation in single-chamber microbial fuel cells.

    Science.gov (United States)

    Li, Yunlong; Zhang, Baogang; Cheng, Ming; Li, Yalong; Hao, Liting; Guo, Huaming

    2016-04-05

    Arsenic is one of the most toxic elements commonly found in groundwater. With initial concentration of 200μgL(-1), spontaneous As(III) oxidation is realized completely during 7 days operation in single-chamber microbial fuel cells (MFCs) in the present study, with the maximum power density of 752.6±17mWm(-2). The product is less toxic and mobile As(V), which can be removed from aqueous solution more easily. High-throughput 16S rRNA gene pyrosequencing analysis indicates the existence of arsenic-resistant bacteria as Actinobacteria, Comamonas, Pseudomonas and arsenic-oxidizing bacteria as Enterobacter, with electrochemically active bacteria as Lactococcus, Enterobacter. They interact together and are responsible for As(III) oxidation and bioelectricity generation in MFCs. This study offers a potential attractive method for remediation of arsenic-polluted groundwater.

  20. A Maximum Likelihood Method for Harmonic Impedance Estimation%系统谐波阻抗估计的极大似然估计方法

    Institute of Scientific and Technical Information of China (English)

    华回春; 贾秀芳; 曹东升; 赵成勇

    2014-01-01

    In order to estimate the harmonic impedance more accurately, the complex maximum likelihood estimation method was proposed in the paper. Firstly, the complex multivariate Gaussian random variable was defined by imitating the real multivariate Gaussian random variable definition. According to the meaning of covariance, the calculation formula of the complex covariance was given. Secondly, the probability density function of the complex Gaussian distribution was deduced by the algebra isomorphism theory. Data selection was performed by the statistical theory, and then the complex maximum likelihood estimation function was established for the selected data. Finally, harmonic impedance was estimated by maximizing the complex maximum likelihood estimation function. A case study based on the IEEE 14-bus test system was operated, which shows that the proposed method can give more accurate result compared with the traditional methods.%为更加准确地估计系统谐波阻抗,提出复数域极大似然估计方法。首先,仿照实数域多元正态分布的定义给出复数域多元正态随机变量的定义,根据协方差的含义,定义复协方差的计算公式。然后利用代数同构理论,推导复数域正态分布的概率密度函数,利用统计学理论进行数据筛选,采用筛选后的数据代入复数域极大似然估计函数。最后利用极值理论进行求解,实现系统谐波阻抗的估计。对IEEE 14节点系统进行仿真,结果表明,与传统方法相比,所提方法估计结果更为准确。

  1. [Approaches to reduce the retroaction of long-term monitoring of bioelectric events in ergonomic field studies (author's transl)].

    Science.gov (United States)

    Zipp, P; Faber, S

    1979-10-01

    When monitoring bioelectric signals the surface electrodes can cause a retroaction on the subject thereby introducing an error of measurement. There are two types of retroaction: physical and psycho-physiological. A physical retroaction due to the hydration process of the skin occurs if 'wet' electrodes are used for the recording of the skin conductance level (SCL) causing a continuous drift of the SCL and a decrease in sensitivity to SCL changes. Therefore a dry electrode was developed with improved performance: It exhibits less sensitivity to motion, is not subject to polarization, and features better SCL long-term stability. When recording the electrocardiogram or the electromyogram a psychophysiological retroaction occurs due to the annoyance caused by the skin-irritating abrading techniques in order to decrease the skin impedance and reduce the motion artifact. In an attempt to abandon the skin preparation whenever permissible without sacrificing the measurement accuracy a performance estimation procedure was developed. Basing on the information on the signal frequency content, the electrode contact area, the required accuracy of measurement and the amplifier input impedance a decision on the necessity of skin preparation is made. Moreover, the results of a study are reported investigating the reduction of motion artifacts by means of electrode design and appropriate electrode jelly formulation.

  2. Compost in plant microbial fuel cell for bioelectricity generation.

    Science.gov (United States)

    Moqsud, M A; Yoshitake, J; Bushra, Q S; Hyodo, M; Omine, K; Strik, David

    2015-02-01

    Recycling of organic waste is an important topic in developing countries as well as developed countries. Compost from organic waste has been used for soil conditioner. In this study, an experiment has been carried out to produce green energy (bioelectricity) by using paddy plant microbial fuel cells (PMFCs) in soil mixed with compost. A total of six buckets filled with the same soil were used with carbon fiber as the electrodes for the test. Rice plants were planted in five of the buckets, with the sixth bucket containing only soil and an external resistance of 100 ohm was used for all cases. It was observed that the cells with rice plants and compost showed higher values of voltage and power density with time. The highest value of voltage showed around 700 mV when a rice plant with 1% compost mixed soil was used, however it was more than 95% less in the case of no rice plant and without compost. Comparing cases with and without compost but with the same number of rice plants, cases with compost depicted higher voltage to as much as 2 times. The power density was also 3 times higher when the compost was used in the paddy PMFCs which indicated the influence of compost on bio-electricity generation. Copyright © 2014 Elsevier Ltd. All rights reserved.

  3. Optically Controlled Oscillators in an Engineered Bioelectric Tissue

    Science.gov (United States)

    McNamara, Harold M.; Zhang, Hongkang; Werley, Christopher A.; Cohen, Adam E.

    2016-07-01

    Complex electrical dynamics in excitable tissues occur throughout biology, but the roles of individual ion channels can be difficult to determine due to the complex nonlinear interactions in native tissue. Here, we ask whether we can engineer a tissue capable of basic information storage and processing, where all functional components are known and well understood. We develop a cell line with four transgenic components: two to enable collective propagation of electrical waves and two to enable optical perturbation and optical readout of membrane potential. We pattern the cell growth to define simple cellular ring oscillators that run stably for >2 h (˜104 cycles ) and that can store data encoded in the direction of electrical circulation. Using patterned optogenetic stimulation, we probe the biophysical attributes of this synthetic excitable tissue in detail, including dispersion relations, curvature-dependent wave front propagation, electrotonic coupling, and boundary effects. We then apply the biophysical characterization to develop an optically reconfigurable bioelectric oscillator. These results demonstrate the feasibility of engineering bioelectric tissues capable of complex information processing with optical input and output.

  4. Frequency range selection method of trans-impedance amplifier for high sensitivity lock-in amplifier used in the optical sensors

    Science.gov (United States)

    Park, Chang-In; Jeon, Su-Jin; Hong, Nam-Pyo; Choi, Young-Wan

    2016-03-01

    Lock-in amplifier (LIA) has been proposed as a detection technique for optical sensors because it can measure low signal in high noise level. LIA uses synchronous method, so the input signal frequency is locked to a reference frequency that is used to carry out the measurements. Generally, input signal frequency of LIA used in optical sensors is determined by modulation frequency of optical signal. It is important to understand the noise characteristics of the trans-impedance amplifier (TIA) to determine the modulation frequency. The TIA has a frequency range in which noise is minimized by the capacitance of photo diode (PD) and the passive component of TIA feedback network. When the modulation frequency is determined in this range, it is possible to design a robust system to noise. In this paper, we propose a method for the determination of optical signal modulation frequency selection by using the noise characteristics of TIA. Frequency response of noise in TIA is measured by spectrum analyzer and minimum noise region is confirmed. The LIA and TIA circuit have been designed as a hybrid circuit. The optical sensor is modeled by the laser diode (LD) and photo diode (PD) and the modulation frequency was used as the input to the signal generator. The experiments were performed to compare the signal to noise ratio (SNR) of the minimum noise region and the others. The results clearly show that the SNR is enhanced in the minimum noise region of TIA.

  5. Impedance and Collective Effects

    CERN Document Server

    Metral, E; Rumolo, R; Herr, W

    2013-01-01

    This document is part of Subvolume C 'Accelerators and Colliders' of Volume 21 'Elementary Particles' of Landolt-Börnstein - Group I 'Elementary Particles, Nuclei and Atoms'. It contains the Chapter '4 Impedance and Collective Effects' with the content: 4 Impedance and Collective Effects Introduction 4.1 Space Charge 4.2 Wake Fields and Impedances 4.3 Coherent Instabilities 4.4 Landau Damping 4.5 Two-Stream Effects (Electron Cloud and Ions) 4.6 Beam-Beam Effects 4.7 Numerical Modelling

  6. Combinatorial materials research applied to the development of new surface coatings X: a high-throughput electrochemical impedance spectroscopy method for screening organic coatings for corrosion inhibition.

    Science.gov (United States)

    He, Jie; Bahr, James; Chisholm, Bret J; Li, Jun; Chen, Zhigang; Balbyshev, Séva N; Bonitz, Verena; Bierwagen, Gordon P

    2008-01-01

    The objective of the study was to develop a high-throughput electrochemical impedance spectroscopy (HT-EIS) method for rapid and quantitative evaluation of corrosion protective coatings. A 12-element, spatially addressable electrochemical platform was designed, fabricated, and validated. This platform was interfaced to a commercial EIS instrument through an automated electronic switching unit. The HT-EIS system enables four parallel EIS measurements to be run simultaneously, which significantly reduces characterization time compared to that of serial EIS measurements using a multiplexer. The performance of the HT-EIS system was validated using a series of model systems, including a Randles equivalent circuit, an electrochemical reaction (Ti/K4FeCN6, K3FeCN6), a highly uniform polymer film, and several polymer coatings. The results of the validation studies showed that the HT-EIS system enables a major reduction in characterization time and provides high quality data comparable to data obtained with conventional, single-cell EIS measurement systems.

  7. Impedance Analysis Method for Sound Insulation of Double Panels%双层板结构隔声性能阻抗法分析

    Institute of Scientific and Technical Information of China (English)

    王佐民; 姜在秀

    2011-01-01

    应用阻抗分析法与少量实样测试相结合的研究途径,探讨具有确定平面尺寸和边界条件的双层板结构的隔声量,进而得到相应的半理论半经验拟合公式.对3种不同夹层形式的双层板结构的倍频程隔声量进行实例分析,得到各自的拟合公式.3种夹层形式分别为吸声材料夹层、空气夹层(空腔)和空气-吸声材料夹层.利用这些拟合公式,可以便捷、高效地开展隔声结构参量的工程筛选.%The sound insulation of double panels with a certain plane dimensions and boundary condition can be analyzed by a combinative way of impedance analysis method and a few measurements, and an expert formula can be obtained. Three kinds of sandwich material constructions were analyzed respectively. Its sound insulations and expert formulae were obtained in octave band. These three kinds of sandwich materials are absorbing sandwich, air sandwich, and air-absorbing sandwich. It will be convenient and high efficient to screen insulation construction parameters by these expert formulae in engineering design.

  8. Impedance and component heating

    CERN Document Server

    Métral, E; Mounet, N; Pieloni, T; Salvant, B

    2015-01-01

    The impedance is a complex function of frequency, which represents, for the plane under consideration (longitudinal, horizontal or vertical), the force integrated over the length of an element, from a “source” to a “test” wave, normalized by their charges. In general, the impedance in a given plane is a nonlinear function of the test and source transverse coordinates, but it is most of the time sufficient to consider only the first few linear terms. Impedances can influence the motion of trailing particles, in the longitudinal and in one or both transverse directions, leading to energy loss, beam instabilities, or producing undesirable secondary effects such as excessive heating of sensitive components at or near the chamber wall, called beam-induced RF heating. The LHC performance limitations linked to impedances encountered during the 2010-2012 run are reviewed and the currently expected situation during the HL-LHC era is discussed.

  9. The LEP impedance model

    Energy Technology Data Exchange (ETDEWEB)

    Zotter, B. [European Organization for Nuclear Research, Geneva (Switzerland)

    1996-08-01

    This report describes a number of measurements and computations of the impedance of the Large Electron Positron collider LEP at CERN. The work has been performed over several years, together with D. Brandt, K. Cornelis, A. Hofmann, G. Sabbi and many others. The agreement between measurements of single bunch instabilities on the machine and computer simulations is in general excellent and gives confidence in the impedance model used. (author)

  10. 基于剩余电流和漏电阻抗的漏电保护方法的研究%Research on method of leakage current protection based on residual current and leakage impedance

    Institute of Scientific and Technical Information of China (English)

    蔡志远; 庞佳; 陈廷辉

    2011-01-01

    Shortage of residual current protection method which can not distinguish the signals caused by switching on the leakage current impedance from those by switching it off is analyzed according to residual current protection theory.A new method based on residual current and leakage current impedance is proposed, which distinguishes the two signals through metering that the real part of impedance is positive or negative, and it can theoretically eliminate the fault performance caused by residual current change due to cutting off leakage current impedance based on original residual current protection.Based on the trigonometric functions, a new method using two points in wave signal to figure out the vector is also proposed.The method is easy for programming and with which the vector parameter needed for computing the leakage impedance can be quickly gotten.%根据剩余电流的保护原理,分析了剩余电流保护中不能够区分由于投入漏电负载和切除漏电负载产生的漏电信号的缺陷,提出了一种基于剩余电流和漏电阻抗的保护方法.该方法通过观察漏电负载阻抗的实部正负特征来加以区分这两种信号,在原有的剩余电流保护方法的基础上,在理论上消除了切除漏电负载引起的剩余电流变化导致的误动作.提出了一种基于三角函数的两点法测定向量参数,易于编程化,能够快速地提取出计算漏电阻抗所需要的向量参数.

  11. Scattering by a groove in an impedance plane

    Science.gov (United States)

    Bindiganavale, Sunil; Volakis, John L.

    1993-09-01

    An analysis of two-dimensional scattering from a narrow groove in an impedance plane is presented. The groove is represented by a impedance surface and the problem reduces to that of scattering from an impedance strip in an otherwise uniform impedance plane. On the basis of this model, appropriate integral equations are constructed using a form of the impedance plane Green's functions involving rapidly convergent integrals. The integral equations are solved by introducing a single basis representation of the equivalent current on the narrow impedance insert. Both transverse electric (TE) and transverse magnetic (TM) polarizations are treated. The resulting solution is validated by comparison with results from the standard boundary integral method (BIM) and a high frequency solution. It is found that the presented solution for narrow impedance inserts can be used in conjunction with the high frequency solution for the characterization of impedance inserts of any given width.

  12. Analysis on electromagnetic scattering by a wedge with impedance faces under exact impedance boundary

    Institute of Scientific and Technical Information of China (English)

    吴良超; 汪茂光

    1995-01-01

    Under the exact impedance boundary condition (EIBC), by using wave equations and the longitudinal field method, the electromagnetic scattenng by an impedance wedge has been analysed in detail, following the Maliuzhinets approach, and the uniform diffraction coefficient of the diffracted field has been presented.

  13. Robot Impedance Control Method Adapting to Unknown or Changing Environment Stiffness and Damping Parameters%适应环境刚度、阻尼参数未知或变化的机器人阻抗控制方法

    Institute of Scientific and Technical Information of China (English)

    李正义; 曹汇敏

    2014-01-01

    针对机器人阻抗控制在实际应用中其性能受环境的阻尼、刚度参数未知或变化影响的问题,提出了一种机器人自适应阻抗控制方法。在定义机器人阻抗控制性能指标的基础上结合阻抗模型刚度变化的几何表示,给出了阻抗模型刚度参数初值计算方法,提出了基于人工神经网络的环境等效刚度在线估计方法,并结合二阶系统临界阻尼条件计算阻抗模型阻尼参数初值。机器人力控制实验结果验证了该方法较已有的机器人阻抗控制方法在参考轨迹平滑性、力控制稳定性和易于工程实践方面有一定的优势。%The robot impedance control performance decreases with the efffects of changing or un-known environment stiffness and damping parameters in practical applications ,this paper presented a self-adaptive robot impedance control method to resolve this problem .Based on the definition of the robot impedance control performance index and the geometric representation for the impedance model stiffness variation ,the calculation method was illustrated for intitial values of the the impedance mod-el stiffness .Designing an artificial neural network to estimate the environmental equivalent stiffness online and combining with critical damping condition of the second-order system ,a calculation method was provided for the impedance model damping initial values .The results of robot force control experi-ments demonstrate smoother reference trajectory ,improved robot force control stability and feasibility in practices compared to the existing robot impedance control methods.

  14. Preoperative Management of Surgical Patients by “Shortened Fasting Time”: A Study on the Amount of Total Body Water by Multi-Frequency Impedance Method

    Directory of Open Access Journals (Sweden)

    Hideki Taniguchi, Toshio Sasaki, Hisae Fujita

    2012-01-01

    Full Text Available Aim: Preoperative fasting is an established procedure to be practiced for patients before surgery, but optimal preoperative fasting time still remains controversial. The aim of this study was to investigate the effect of “shortened preoperative fasting time” on the change in the amount of total body water (TBW in elective surgical patients. TBW was measured by multi-frequency impedance method.Methods: The patients, who were scheduled to undergo surgery for stomach cancer, were divided into two groups of 15 patients each. Before surgery, patients in the control group were managed with conventional preoperative fasting time, while patients in the “enhanced recovery after surgery (ERAS” group were managed with “shortened preoperative fasting time” and “reduced laxative medication.” TBW was measured on the day before surgery and the day of surgery before entering the operating room. Defecation times and anesthesia-related vomiting and aspiration were monitored.Results: TBW values on the day of surgery showed changes in both groups as compared with those on the day before surgery, but the rate of change was smaller in the ERAS group than in the control group (2.4±6.8% [12 patients] vs. −10.6±4.6% [14 patients], p<0.001. Defecation times were less in the ERAS group. Vomiting and aspiration were not observed in either group.Conclusion: The results suggest that preoperative management with “shorted preoperative fasting time” and “reduced administration of laxatives” is effective in the maintenance of TBW in elective surgical patients.

  15. Electrical Impedance Measurements of PZT Nanofiber Sensors

    Directory of Open Access Journals (Sweden)

    Richard Galos

    2017-01-01

    Full Text Available Electrical impedance measurements of PZT nanofiber sensors were performed using a variety of methods over a frequency spectrum ranging from DC to 1.8 GHz. The nanofibers formed by electrospinning with diameters ranging from 10 to 150 nm were collected and integrated into sensors using microfabrication techniques. Special matching circuits with ultrahigh input impedance were fabricated to produce low noise, measurable sensor outputs. Material properties including resistivity and dielectric constant are derived from the impedance measurements. The resulting material properties are also compared with those of individual nanofibers being tested using conductive AFM and Scanning Conductive Microscopy.

  16. A review of impedance measurements of whole cells.

    Science.gov (United States)

    Xu, Youchun; Xie, Xinwu; Duan, Yong; Wang, Lei; Cheng, Zhen; Cheng, Jing

    2016-03-15

    Impedance measurement of live biological cells is widely accepted as a label free, non-invasive and quantitative analytical method to assess cell status. This method is easy-to-use and flexible for device design and fabrication. In this review, three typical techniques for impedance measurement, i.e., electric cell-substrate impedance sensing, Impedance flow cytometry and electric impedance spectroscopy, are reviewed from the aspects of theory, to electrode design and fabrication, and applications. Benefiting from the integration of microelectronic and microfluidic techniques, impedance sensing methods have expanded their applications to nearly all aspects of biology, including living cell counting and analysis, cell biology research, cancer research, drug screening, and food and environmental safety monitoring. The integration with other techniques, the fabrication of devices for certain biological assays, and the development of point-of-need diagnosis devices is predicted to be future trend for impedance sensing techniques. Copyright © 2015 Elsevier B.V. All rights reserved.

  17. Bioelectricity-AQA, one of the first MOOC courses in engineering.

    Science.gov (United States)

    Barr, Roger C

    2014-01-01

    Bioelectricity-AQA was one of the first massively open online courses in engineering, having been given the first time via Coursera starting in September, 2012. This report provides some detail on its background, presentation, enrollment, and lessons learned.

  18. Finemet cavity impedance studies

    CERN Document Server

    Persichelli, S; Migliorati, M; Salvant, B

    2013-01-01

    The aim of the study is to evaluate the impedance of the Finemet kicker cavity to be installed in the PS straight section 02 during LS1, under realistic assumptions of bunch length. Time domain simulations with CST Particle Studio have been performed in order to get the impedance of the cavity and make a comparison with the longitudinal impedance measured for a single cell prototype. The study has been performed on simplified 3D geometries imported from a mechanical CATIA drawing, assuming that the simplications have small impact on the nal results. Simulations confirmed that the longitudinal impedance observed with measurements can be excited by bunches circulating in the PS. In the six-cells Finemet cavity, PS bunches circulating in the center can excite a longitudinal impedance, the real part of which has a maximum of 2 kOhm at 4 MHz. This mode does not seem to have any transverse component. All the eigenmodes of the cavity are strongly damped by the Finemet rings: we predict to have no issues regarding tr...

  19. Response Characteristics of Plant Bioelectric Potential to Light Intensity Indoor and Outdoor

    Science.gov (United States)

    Shimbo, Tatsuya; Fujii, Masaki; Sawada, Ayako; Oyabu, Takashi; Kimura, Haruhiko

    Plant is affected by environmental factors. For example, these are temperature, humidity and light intensity. The light intensity affected strongly to the plant. The plant produces glucose and oxygen with photosynthesis. Moreover, light intensity is important to purify the contaminants in the atmosphere. In this study, it was examined whether the plant is affected by temperature, wind grade and soil moisture using bioelectric potential characteristics of the plant. Especially plant bioelectric potential to light intensity change was measured. The measurement was carried out in indoor and outdoor. As for the result, the differences of plant bioelectric potential characteristics in the indoor and outdoor were recognized. At that analysis, the integrated value of plant bioelectric potential for 1 minute (vm1) was adopted. Moreover, a high correlation was indicated between the vm1 and light intensity. The correlation coefficient was R2=0.94. It becomes obvious that the plant is affected strongly by light intensity and the plant can understand the environmental factors like light intensity. The characteristics are found by measuring bioelectric potential of the plant. The environmental sensing can be possible by the use of the plant bioelectric potential.

  20. A wave dynamic response matrix method for solving problems about impeding structure-borne sound transmission from composite wave impedance technique%组合波阻技术的波动力响应矩阵分析法及其特性研究

    Institute of Scientific and Technical Information of China (English)

    林永水; 吴卫国; 甘进

    2016-01-01

    This paper proposes a wave dynamic response matrix method to investigate the problem of im-peding structure-borne sound transmission from wave impedance facilities based on the wave approach, impedance method and finite element idea. The structure is discretized into many wave elements and a gen-eral wave dynamic response equilibrium equation is developed according to the displacement compatibility, force and moment equilibrium at the junction node. And, the wave dynamic response matrices of wave ele-ments and the added wave dynamic response matrices of wave impedance facilities are deduced. The vibra-tion amplitudes of wave elements are obtained by resolving the equilibrium equation and the transmission efficiencies and transmission loss are then obtained. The method is illustrated by a series of wave attenua-tion models such as blocking mass, elastic interlayer and dynamic vibration absorber. Finally, numerical analysis focuses on the attenuation of structure-borne sound through the composite wave impedance facilities.The numerical simulation results show that the wave transmission loss of the whole frequency domain will be greatly improved by using composite wave impedance technique with reasonable selection of design pa-rameters and the optimal layout. This study provides a new analysis method for the structural acoustic design of composite wave impedance facilities and a new kind of control policy, which has great theoretical signif-icance and important value for engineering application in the field of noise and vibration reduction.%基于有限元思想,综合运用波分析法和阻抗法,提出了波阻元件阻抑结构声传递的波动力响应矩阵分析法。将结构离散为多个波导单元和波阻单元,根据连接节点的位移连续,力与力矩平衡,建立附加波阻元件的结构连接广义波动力响应平衡方程,推导出波单元波动力响应特征矩阵及波阻元件附加波动响应特征矩阵,并代入波

  1. Impeded Dark Matter

    CERN Document Server

    Kopp, Joachim; Slatyer, Tracy R; Wang, Xiao-Ping; Xue, Wei

    2016-01-01

    We consider a new class of thermal dark matter models, dubbed "Impeded Dark Matter", in which the mass splitting between the dark matter particles and their annihilation products is tiny. Compared to the previously proposed Forbidden Dark Matter scenario, the mass splittings we consider are much smaller, and are allowed to be either positive or negative. We demonstrate that either case can be easily realized without requiring tuning of model parameters. For negative mass splitting, we demonstrate that the annihilation cross-section for Impeded Dark Matter depends linearly on the dark matter velocity or may even be kinematically forbidden, making this scenario almost insensitive to constraints from the cosmic microwave background and from observations of dwarf galaxies. Accordingly, it may be possible for Impeded Dark Matter to yield observable signals in clusters or the Galactic center, with no corresponding signal in dwarfs. For positive mass splitting, we show that the annihilation cross-section is suppress...

  2. Impedance adaptation for optimal robot-environment interaction

    Science.gov (United States)

    Ge, Shuzhi Sam; Li, Yanan; Wang, Chen

    2014-02-01

    In this paper, impedance adaptation is investigated for robots interacting with unknown environments. Impedance control is employed for the physical interaction between robots and environments, subject to unknown and uncertain environments dynamics. The unknown environments are described as linear systems with unknown dynamics, based on which the desired impedance model is obtained. A cost function that measures the tracking error and interaction force is defined, and the critical impedance parameters are found to minimise it. Without requiring the information of the environments dynamics, the proposed impedance adaptation is feasible in a large number of applications where robots physically interact with unknown environments. The validity of the proposed method is verified through simulation studies.

  3. Broadband electrical impedance matching for piezoelectric ultrasound transducers.

    Science.gov (United States)

    Huang, Haiying; Paramo, Daniel

    2011-12-01

    This paper presents a systematic method for designing broadband electrical impedance matching networks for piezoelectric ultrasound transducers. The design process involves three steps: 1) determine the equivalent circuit of the unmatched piezoelectric transducer based on its measured admittance; 2) design a set of impedance matching networks using a computerized Smith chart; and 3) establish the simulation model of the matched transducer to evaluate the gain and bandwidth of the impedance matching networks. The effectiveness of the presented approach is demonstrated through the design, implementation, and characterization of impedance matching networks for a broadband acoustic emission sensor. The impedance matching network improved the power of the acquired signal by 9 times.

  4. Biased low differential input impedance current receiver/converter device and method for low noise readout from voltage-controlled detectors

    Science.gov (United States)

    Degtiarenko, Pavel V.; Popov, Vladimir E.

    2011-03-22

    A first stage electronic system for receiving charge or current from voltage-controlled sensors or detectors that includes a low input impedance current receiver/converter device (for example, a transimpedance amplifier), which is directly coupled to the sensor output, a source of bias voltage, and the device's power supply (or supplies), which use the biased voltage point as a baseline.

  5. Negative transverse impedance

    Energy Technology Data Exchange (ETDEWEB)

    Chou, W.

    1989-06-12

    Recently, measurements in the SPS show that the coherent tune shift in the horizontal direction has positive values whereas that in the vertical direction has negative ones. Thus the existence of negative transverse impedance gets confirmed in a real machine. This stimulates us to start a new round of systematic studies on this interesting phenomenon. The results obtained from our computer simulations are presented in this note. Our simulations demonstrate that the negative transverse impedance may appear when the rotational symmetry embedded in a discontinuity is broken, and that the geometries that we have studies may be the source of the positive horizontal tune shift measured in the SPS.

  6. Impedance spectroscopy of food mycotoxins

    Science.gov (United States)

    Bilyy, Oleksandr I.; Yaremyk, Roman Ya.; Kotsyumbas, Ihor Ya.; Kotsyumbas, Halyna I.

    2012-01-01

    A new analytical method of high-selective detection of mycotoxins in food and feed are considered. A method is based on optical registration the changes of conduct of the electric polarized bacterial agents in solution at the action of the external gradient electric fields. Measuring are conducted in integrated electrode-optical cuvette of the special construction, which provides the photometric analysis of forward motion of the objects registration in liquid solution under act of the enclosed electric field and simultaneous registration of kinetics of change of electrical impedance parameters solution and electrode system.

  7. VISUALIZATION OF BIOLOGICAL TISSUE IMPEDANCE PARAMETERS

    Directory of Open Access Journals (Sweden)

    V. I. Bankov

    2016-01-01

    Full Text Available Objective. Investigation the opportunity for measurement of biological tissue impedance to visualize its parameters.Materials and methods. Studies were undertook on the experimental facility, consists of registrating measuring cell, constructed from flat inductors system, formed in oscillatory circuit, herewith investigated biological tissue is the part of this oscillatory circuit. An excitation of oscillatory circuit fulfilled by means of exciter inductor which forms impulse complex modulated electromagnetic field (ICM EMF. The measurement process and visualizations provided by set of certificated instruments: a digital oscillograph AKTAKOM ADS-2221MV, a digital generator АКТАКОМ AWG-4150 (both with software and a gauge RLC E7-22. Comparative dynamic studies of fixed volume and weight pig’s blood, adipose tissue, muscular tissue impedance were conducted by contact versus contactless methods. Contactless method in contrast to contact method gives opportunity to obtain the real morphological visualization of biological tissue irrespective of their nature.Results. Comparison of contact and contactless methods of impedance measurement shows that the inductance to capacitance ratio X(L / X(C was equal: 17 – for muscular tissue, 4 – for blood, 1 – for adipose tissue. It demonstrates the technical correspondence of both impedance registration methods. If propose the base relevance of X (L and X (C parameters for biological tissue impedance so contactless measurement method for sure shows insulating properties of adipose tissue and high conductivity for blood and muscular tissue in fixed volume-weight parameters. Registration of biological tissue impedance complex parameters by contactless method with the help of induced ICM EMF in fixed volume of biological tissue uncovers the most important informative volumes to characterize morphofunctional condition of biological tissue namely X (L / X (C.Conclusion. Contactless method of biological

  8. Wave impedance retrieving via Bloch modes analysis

    DEFF Research Database (Denmark)

    Andryieuski, Andrei; Ha, S.; Sukhorukov, A.;

    2011-01-01

    of the Bloch mode, respectively. Case studies prove that our ap-proach can determine material and wave effective parameters of lossy and lossless metamaterials. In some examples when the passivity is violated we made further analysis and showed that this is due to the failure of concept of impedance retrieving......-ciples violation, like antiresonance behaviour with Im(ε) mode analysis of periodic metamaterials to extract the dominating (fundamental) Bloch mode. Then it is possible to determine the Bloch and wave impedances by the surface and volume aver-aging of the electromagnetic field......The main bottleneck in the restoration of electromagnetic effective parameters is connected to the impedance retrieving. The S-parameters method gives the input (Bloch) impedance, which, being then used for permittivity and permeability determination, causes some fundamental physics prin...

  9. A Rotative Electrical Impedance Tomography Reconstruction System

    Energy Technology Data Exchange (ETDEWEB)

    Yu, F-M [St. John' s and St. Mary' s Institute of Technology, Department of computer science and information Engineering, 499, Sec. 4, Tam King Road Tamsui, Taipei, Taiwan (China); Huang, C-N [National Central University, Department of Electrical Engineering, No.300, Jungda Rd, Jhongli City, 320 Taoyuan, Taiwan (China); Chang, F-W [National Central University, Department of Electrical Engineering, No.300, Jungda Rd, Jhongli City, 320 Taoyuan, Taiwan (China); Chung, H-Y [National Central University, Department of Electrical Engineering, No.300, Jungda Rd, Jhongli City, 320 Taoyuan, Taiwan (China)

    2006-10-15

    Electrical impedance tomography (EIT) is a powerful tool for mapping the conductivity distribution of estimated objects. The EIT system is entirely implemented by electrical technique, so it is a relatively cheap system and data can be collected very rapidly. But it has few commercially medical EIT systems available. This is because impedance image unable to achieve the essential spatial resolution and this technique has an intrinsically poor signal to noise ratio. In this paper, we have developed a high performance rotative EIT system (REIT) for expanding the independent measurements. By rotate the electrodes successive, REIT could change the position of electrodes and acquire more measurement data. This rotative measurement method not only can increase the resolution of impedance images, but also reduce the complexity of measurement system. We hope the improvement of REIT will bring some help in electrical impedance tomography.

  10. A new method to obtain narrowband emission from a broadband current using increased impedance of plasma-like media (Conference Presentation)

    Science.gov (United States)

    Hur, Min Sup; Ersfeld, Bernhard; Noble, Adam; Suk, Hyyong; Jaroszynski, Dino A.

    2017-05-01

    In conventional radiation sources, narrowband radiation emission can be obtained by narrowband current oscillation. Usually the spectrum of the oscillating current is made narrow by a large or complicated structure for wave-particle interaction. One good example is the beam-undulator system. In this presentation, we introduce a new method to obtain a radiation emission with a well-collimated frequency without changing the broadband nature of a given current source. The method is based on our recent discovery of the new physical properties of the cut-off phenomenon, which broadly exists in general plasma-like media, such as plasma, waveguide, or photonic crystal, etc. A common feature of these media is the Bohm-Gross dispersion relation, which has a frequency condition to make the wavenumber zero. In the zero-wavenumber state, an electromagnetic wave cannot propagate through the medium, but instead, is reflected (i.e. cut-off). In regular steady-state analysis, the cut-off condition is characterized by infinite radiation impedance. An interesting question here is what would happen to the radiation power, if a non-zero current oscillating with the cut-off frequency were enforced in a medium (a current source, in contrast with the regular voltage source). A regular steady-state analysis for this situation leads to infinite power of radiation from Ohm's law. We could solve such a paradoxical situation by analyzing the non-steady-state system; we found that the system can be described by a time-dependent Schroedinger equation with an external driving term. The solution of this equation shows a temporally growing electromagnetic field. When this concept is extended to a generally broadband current source, the spectral density at the cut-off frequency can be selectively enhanced (selectively enhanced emission, SEE). Hence a general broadband radiation source can be easily converted to a narrowband source by enclosing the system with a plasma-like medium. The current

  11. Impedance pattern of vaginal and vestibular mucosa in cyclic goats

    Directory of Open Access Journals (Sweden)

    Ivo Křivánek

    2008-01-01

    Full Text Available The changes of vaginal and vestibular impedance during the oestrous cycle in goats were examined. The onset of oestrus was teased with a buck once a day during the experiment. Impedance was mea­sured by a four-terminal method. The vaginal impedance was recorded under slight pressure of electrodes to the vaginal dorsal wall at the cervix. The vestibular impedance was recorded under slight pressure of electrodes to the vestibular dorsal wall 5 cm from the vulva and at the vulva. The im­pe­dan­ce was measured once a day from 4 days before the expected oestrus to 6 days after onset of oestrus. The vaginal impedance at the cervix decreased during pro-oestrus (P < 0.01 and increased du­ring oestrus (P < 0.01. The vestibular impedance 5 cm from the vulva decreased during pro-oestrus (P < 0.01 and increased after oestrus (P < 0.01. The decrease of vaginal impedance during peri-oestrus was nearly twofold in comparison with the vestibular impedance 5 cm from the vulva. No sig­ni­fi­cant decrease of the vestibular impedance at the vulva was found during the oestrous cycle. The results indicate that the vaginal impedance at the cervix and vestibular impedance 5 cm from the vulva measured by means of a four-terminal method during the oestrous cycle display cyclic changes that are closely related to the oestrous behaviour of goats.

  12. 三相不对称条件下的电网阻抗检测方法%A Grid Impedance Detection Method Under Unbalanced Three-phase Conditions

    Institute of Scientific and Technical Information of China (English)

    蔡文; 刘邦银; 段善旭; 邹常跃

    2012-01-01

    Grid impedance detection is an anti-islanding method which is widely used in grid-connected inverters.Grid-impedance detection based on the single harmonic current injection is feasible in single-phase and balanced three-phase grids.However,under unbalanced three-phase conditions,the harmonic voltage caused by the injected symmetric harmonic current is asymmetric,which affects the computation of the impedances and leads to a failed detection.Firstly,this paper analyzed the failure mechanism of the conventional grid-impedance detection under unbalanced three-phase conditions.And then,a new method wais proposed to detect the impedances of the grid with two different non-characteristic harmonic current injections and the Discrete Fourier Transformation(DFT) algorithm.Finally,experiments were carried out in impedance-unbalanced grids.Theoretical analysis and experiment results prove that the proposed method is feasible.%电网阻抗检测法是一种在并网逆变器中广泛使用的孤岛检测方法。基于单次谐波电流注入的常规电网阻抗检测法在单相和三相对称电网中可准确检测出孤岛,但当三相电网不对称时,注入的对称谐波电流将引起谐波电压不对称,从而影响电网阻抗的计算,可能导致孤岛检测失败。该文首先分析了基于谐波电流注入的常规阻抗检测方法在三相不对称条件下的失效机理,然后提出一种采用2种不同频率非特征谐波电流注入的方式,结合离散傅里叶变换(discrete Fourier transformation,DFT)算法检测三相电网阻抗的方法,并分析了该方法的基本原理和性能,最后在三相电网阻抗不对称的条件下进行了实验验证。理论分析和实验结果表明该文所提出的阻抗检测方法是有效可行的。

  13. Antenna impedance matching with neural networks.

    Science.gov (United States)

    Hemminger, Thomas L

    2005-10-01

    Impedance matching between transmission lines and antennas is an important and fundamental concept in electromagnetic theory. One definition of antenna impedance is the resistance and reactance seen at the antenna terminals or the ratio of electric to magnetic fields at the input. The primary intent of this paper is real-time compensation for changes in the driving point impedance of an antenna due to frequency deviations. In general, the driving point impedance of an antenna or antenna array is computed by numerical methods such as the method of moments or similar techniques. Some configurations do lend themselves to analytical solutions, which will be the primary focus of this work. This paper employs a neural control system to match antenna feed lines to two common antennas during frequency sweeps. In practice, impedance matching is performed off-line with Smith charts or relatively complex formulas but they rarely perform optimally over a large bandwidth. There have been very few attempts to compensate for matching errors while the transmission system is in operation and most techniques have been targeted to a relatively small range of frequencies. The approach proposed here employs three small neural networks to perform real-time impedance matching over a broad range of frequencies during transmitter operation. Double stub tuners are being explored in this paper but the approach can certainly be applied to other methodologies. The ultimate purpose of this work is the development of an inexpensive microcontroller-based system.

  14. Longitudinal impedance of RHIC

    Energy Technology Data Exchange (ETDEWEB)

    Blaskiewicz, M. [Brookhaven National Lab. (BNL), Upton, NY (United States); Brennan, J. M. [Brookhaven National Lab. (BNL), Upton, NY (United States); Mernick, K. [Brookhaven National Lab. (BNL), Upton, NY (United States)

    2015-05-03

    The longitudinal impedance of the two RHIC rings has been measured using the effect of potential well distortion on longitudinal Schottky measurements. For the blue RHIC ring Im(Z/n) = 1.5±0.2Ω. For the yellow ring Im(Z/n) = 5.4±1Ω.

  15. Locating Impedance Change in Electrical Impedance Tomography Based on Multilevel BP Neural Network

    Institute of Scientific and Technical Information of China (English)

    彭源; 莫玉龙

    2003-01-01

    Electrical impedance tomography (EIT) is a new computer tomography technology, which reconstructs an impedance (resistivity, conductivity) distribution, or change of impedance, by making voltage and current measurements on the object's periphery.Image reconstruction in EIT is an ill-posed, non-linear inverse problem. A method for finding the place of impedance change in EIT is proposed in this paper, in which a multilevel BP neural network (MBPNN) is used to express the non-linear relation between theimpedance change inside the object and the voltage change measured on the surface of the object. Thus, the location of the impedance change can be decided by the measured voltage variation on the surface. The impedance change is then reconstructed using a linear approximate method. MBPNN can decide the impedance change location exactly without long training time. It alleviates some noise effects and can be expanded, ensuring high precision and space resolution of the reconstructed image that are not possible by using the back projection method.

  16. Optimisation of the Low-Frequency Response of a Multi-stage Bioelectric Amplifier for Electrocardiogram (ECG Recording

    Directory of Open Access Journals (Sweden)

    Burke Martin J.

    2016-01-01

    Full Text Available This paper reports the optimisation of the low-frequency response of a multi-stage bioelectric amplifier intended for use in the measurement of the human electrocardiogram (ECG using high-impedance un-gelled electrodes. The frequency response was optimised to meet international performance requirements for electrocardiographic recorders, in particular the International Electrotechnical Commission 60601 standards [1,2]. The pole and zero locations of a multi-stage amplifier configuration were optimised to meet both time and frequency domain specifications. The optimum assignment for a three stage amplifier, having two differential stages and a differential-to-single-ended conversion stage was established by evaluating the performance of a number of circuit configurations. The optimum configuration was found to be two differential stages with a gain of 20dB each and a differential-to single-ended output stage with unity gain. The -3dB pole is placed at 0.028Hz and a zero at 0.0028Hz in the first and second stages to give an overall -3dB bandwidth of 0.043Hz. In addition, the pole of the input ac coupling network was placed at 0.0028Hz in order to meet the undershoot and recovery slope requirements in the narrow pulse response.

  17. Endogenous bioelectrical networks store non-genetic patterning information during development and regeneration.

    Science.gov (United States)

    Levin, Michael

    2014-06-01

    Pattern formation, as occurs during embryogenesis or regeneration, is the crucial link between genotype and the functions upon which selection operates. Even cancer and aging can be seen as challenges to the continuous physiological processes that orchestrate individual cell activities toward the anatomical needs of an organism. Thus, the origin and maintenance of complex biological shape is a fundamental question for cell, developmental, and evolutionary biology, as well as for biomedicine. It has long been recognized that slow bioelectrical gradients can control cell behaviors and morphogenesis. Here, I review recent molecular data that implicate endogenous spatio-temporal patterns of resting potentials among non-excitable cells as instructive cues in embryogenesis, regeneration, and cancer. Functional data have implicated gradients of resting potential in processes such as limb regeneration, eye induction, craniofacial patterning, and head-tail polarity, as well as in metastatic transformation and tumorigenesis. The genome is tightly linked to bioelectric signaling, via ion channel proteins that shape the gradients, downstream genes whose transcription is regulated by voltage, and transduction machinery that converts changes in bioelectric state to second-messenger cascades. However, the data clearly indicate that bioelectric signaling is an autonomous layer of control not reducible to a biochemical or genetic account of cell state. The real-time dynamics of bioelectric communication among cells are not fully captured by transcriptomic or proteomic analyses, and the necessary-and-sufficient triggers for specific changes in growth and form can be physiological states, while the underlying gene loci are free to diverge. The next steps in this exciting new field include the development of novel conceptual tools for understanding the anatomical semantics encoded in non-neural bioelectrical networks, and of improved biophysical tools for reading and writing

  18. Impedance spectroscopy--an outstanding method for label-free and real-time discrimination between brain and tumor tissue in vivo.

    Science.gov (United States)

    Jahnke, Heinz-Georg; Heimann, Axel; Azendorf, Ronny; Mpoukouvalas, Konstantinos; Kempski, Oliver; Robitzki, Andrea A; Charalampaki, Patra

    2013-08-15

    Until today, brain tumors especially glioblastoma are difficult to treat and therefore, results in a poor survival rate of 0-14% over five years. To overcome this problem, the development of novel therapeutics as well as optimization of neurosurgical procedures to remove the tumor tissue are subject of intensive research. The main problem of the tumor excision, as the primary clinical intervention is the diffuse infiltration of the tumor cells in unaltered brain tissue that complicates the complete removal of residual tumor cells. In this context, we are developing novel approaches for the label-free discrimination between tumor tissue and unaltered brain tissue in real-time during the surgical process. Using our impedance spectroscopy-based measurement system in combination with flexible microelectrode arrays we could successfully demonstrate the discrimination between a C6-glioma and unaltered brain tissue in an in vivo rat model. The analysis of the impedance spectra revealed specific impedance spectrum shape characteristics of physiologic neuronal tissue in the frequency range of 10-500 kHz that were significantly different from the tumor tissue. Moreover, we used an adapted equivalent circuit model to get a deeper understanding for the nature of the observed effects. The impedimetric label-free and real-time discrimination of tumor from unaltered brain tissue offers the possibility for the implementation in surgical instruments to support surgeons to decide, which tissue areas should be removed and which should be remained.

  19. Microbiology and optimization of hydrogen fermentation and bioelectricity production

    Energy Technology Data Exchange (ETDEWEB)

    Makinen, A.

    2013-11-01

    This work investigated dark fermentative hydrogen (H{sub 2}) and bioelectricity production from carbohydrates. Meso- and thermophilic fermentative and mesophilic exoelectrogenic bacteria were enriched from different natural sources. The H{sub 2} production from different hexoses and pentoses, them main constituents of lignocellulose, was studied in batch assays. H{sub 2} production from xylose was examined in continuous stirred tank reactor (CSTR). Operational parameters for H{sub 2} production were optimized. Bioelectricity production was studied in microbial fuel cells and process parameters were optimized. Dynamics of microbial communities in H{sub 2} and bioelectricity production processes were determined. A novel thermophilic dark fermentative H{sub 2} producing bacterium, Thermovorax subterraneus, was enriched and isolated from geothermal underground mine. T. subterraneus had the optimum growth temperature of 72 deg C and the maximum H{sub 2} yield of 1.4 mol/mol glucose in batch assay. The main soluble fermentative end products of T. subterraneus were acetate and ethanol. Thermophilic dark fermentative mixed culture enriched from hot spring (Hisarlan, Turkey) had the maximum H{sub 2} yield of 1.7 mol/mol glucose. The optimal environmental parameters to maximize H{sub 2} yield were temperature 52 deg C, initial pH 6.5, 40 mg/L Fe{sup 2+}, 4.5 g/L yeast extract and glucose concentration of 4 g/L. Increasing the glucose concentration to 18 g/L increased the maximum H{sub 2} production rate to 56.2 mmol H{sub 2}/h/L. Environmental parameters had a significant effect on metabolic pathways of fermentation. Another hot spring (Hisarkoy, Turkey) enrichment culture was able to ferment different sugars to H{sub 2} favoring pentoses over hexoses. The best H{sub 2} yields in batch assays were obtained from pentoses: xylose, arabinose and ribose yielded 21, 15 and 8 % of the theoretical yield, respectively; whilst on glucose the yield was only 2 % of the theoretical

  20. Impedance calculation for ferrite inserts

    Energy Technology Data Exchange (ETDEWEB)

    Breitzmann, S.C.; Lee, S.Y.; /Indiana U.; Ng, K.Y.; /Fermilab

    2005-01-01

    Passive ferrite inserts were used to compensate the space charge impedance in high intensity space charge dominated accelerators. They study the narrowband longitudinal impedance of these ferrite inserts. they find that the shunt impedance and the quality factor for ferrite inserts are inversely proportional to the imaginary part of the permeability of ferrite materials. They also provide a recipe for attaining a truly passive space charge impedance compensation and avoiding narrowband microwave instabilities.

  1. DIFFERENTIAL SOIL IMPEDANCE OBSTACLE DETECTION

    Energy Technology Data Exchange (ETDEWEB)

    Maximillian J. Kieba; Christopher J. Ziolkowski

    2004-06-30

    This project develops a new and unique obstacle detection sensor for horizontal directional drilling (HDD) equipment. The development of this new technology will greatly improve the reliability and safety of natural gas HDD construction practices. This sensor utilizes a differential soil impedance measurement technique that will be sensitive to the presence of plastic and ceramic, as well as metallic obstacles. The use of HDD equipment has risen significantly in the gas industry because HDD provides a much more cost-effective and less disruptive method for gas pipe installation than older, trenching methods. However, there have been isolated strikes of underground utilities by HDD equipment, which may have been avoided if methods were available to detect other underground obstacles when using HDD systems. GTI advisors from the gas industry have ranked the value of solving the obstacle detection problem as the most important research and development project for GTI to pursue using Federal Energy Regulatory Commission (FERC) funds available through its industry partner, GRI. GTI proposes to develop a prototype down-hole sensor system that is simple and compact. The sensor utilizes an impedance measurement technique that is sensitive to the presence of metallic or nonmetallic objects in the proximity of the HDD head. The system will use a simple sensor incorporated into the drill head. The impedance of the soil will be measured with a low frequency signal injected through the drill head itself. A pair of bridge type impedance sensors, mounted orthogonal to one another, is coupled to the soil. Inclusions in the soil will cause changes to the sensor balance distinguishable from homogeneous soil. The sensor will provide range and direction data for obstacles near the HDD head. The goal is to provide a simple, robust system that provides the information required to avoid obstacles. This must be done within the size and ruggedness constraints of the HDD equipment. Imaging

  2. DIFFERENTIAL SOIL IMPEDANCE OBSTACLE DETECTION

    Energy Technology Data Exchange (ETDEWEB)

    Maximillian J. Kieba

    2003-10-01

    This project develops a new and unique obstacle detection sensor for horizontal directional drilling (HDD) equipment. The development of this new technology will greatly improve the reliability and safety of natural gas HDD construction practices. This sensor utilizes a differential soil impedance measurement technique that will be sensitive to the presence of plastic and ceramic, as well as metallic obstacles. The use of HDD equipment has risen significantly in the gas industry because HDD provides a much more cost-effective and less disruptive method for gas pipe installation than older, trenching methods. However, there have been isolated strikes of underground utilities by HDD equipment, which may have been avoided if methods were available to detect other underground obstacles when using HDD systems. GTI advisors from the gas industry have ranked the value of solving the obstacle detection problem as the most important research and development project for GTI to pursue using Federal Energy Regulatory Commission (FERC) funds available through its industry partner, GRI. GTI proposes to develop a prototype down-hole sensor system that is simple and compact. The sensor utilizes an impedance measurement technique that is sensitive to the presence of metallic or nonmetallic objects in the proximity of the HDD head. The system will use a simple sensor incorporated into the drill head. The impedance of the soil will be measured with a low frequency signal injected through the drill head itself. A pair of bridge type impedance sensors, mounted orthogonal to one another, is coupled to the soil. Inclusions in the soil will cause changes to the sensor balance distinguishable from homogeneous soil. The sensor will provide range and direction data for obstacles near the HDD head. The goal is to provide a simple, robust system that provides the information required to avoid obstacles. This must be done within the size and ruggedness constraints of the HDD equipment. Imaging

  3. DIFFERENTIAL SOIL IMPEDANCE OBSTACLE DETECTION

    Energy Technology Data Exchange (ETDEWEB)

    Maximillian J. Kieba

    2003-04-01

    This project develops a new and unique obstacle detection sensor for horizontal directional drilling (HDD) equipment. The development of this new technology will greatly improve the reliability and safety of natural gas HDD construction practices. This sensor utilizes a differential soil impedance measurement technique that will be sensitive to the presence of plastic and ceramic, as well as metallic obstacles. The use of HDD equipment has risen significantly in the gas industry because HDD provides a much more cost-effective and less disruptive method for gas pipe installation than older, trenching methods. However, there have been isolated strikes of underground utilities by HDD equipment, which may have been avoided if methods were available to detect other underground obstacles when using HDD systems. GTI advisors from the gas industry have ranked the value of solving the obstacle detection problem as the most important research and development project for GTI to pursue using Federal Energy Regulatory Commission (FERC) funds available through its industry partner, GRI. GTI proposes to develop a prototype down-hole sensor system that is simple and compact. The sensor utilizes an impedance measurement technique that is sensitive to the presence of metallic or nonmetallic objects in the proximity of the HDD head. The system will use a thin film sensor conformal with the drill head. The impedance of the soil will be measured with a low frequency signal injected through the drill head itself. A pair of bridge type impedance sensors, mounted orthogonal to one another, is capacitively coupled to the soil. Inclusions in the soil will cause changes to the sensor balance distinguishable from homogeneous soil. The sensor will provide range and direction data for obstacles near the HDD head. The goal is to provide a simple, robust system that provides the information required to avoid obstacles. This must be done within the size and ruggedness constraints of the HDD

  4. DIFFERENTIAL SOIL IMPEDANCE OBSTACLE DETECTION

    Energy Technology Data Exchange (ETDEWEB)

    Maximillian J. Kieba; Christopher J. Ziolkowski

    2005-01-17

    This project aimed at developing a new and unique obstacle detection sensor for horizontal directional drilling (HDD) equipment. The development of this new technology will greatly improve the reliability and safety of natural gas HDD construction practices. This sensor utilizes a differential soil impedance measurement technique that will be sensitive to the presence of plastic and ceramic, as well as metallic obstacles. The use of HDD equipment has risen significantly in the gas industry because HDD provides a much more cost-effective and less disruptive method for gas pipe installation than older, trenching methods. However, there have been isolated strikes of underground utilities by HDD equipment, which may have been avoided if methods were available to detect other underground obstacles when using HDD systems. GTI advisors from the gas industry ranked the value of solving the obstacle detection problem as the most important research and development project for GTI to pursue using Federal Energy Regulatory Commission (FERC) funds available through its industry partner, GTI. GTI proposed to develop a prototype down-hole sensor system that is simple and compact. The sensor utilizes an impedance measurement technique that is sensitive to the presence of metallic or non-metallic objects in the proximity of the HDD head. The system will use a simple sensor incorporated into the drill head. The impedance of the soil will be measured with a low frequency signal injected through the drill head itself. A pair of bridge type impedance sensors, mounted orthogonal to one another, is coupled to the soil. Inclusions in the soil will cause changes to the sensor balance distinguishable from homogeneous soil. The sensor will provide range and direction data for obstacles near the HDD head. The goal is to provide a simple, robust system that provides the information required to avoid obstacles. This must be done within the size and ruggedness constraints of the HDD equipment

  5. DIFFERENTIAL SOIL IMPEDANCE OBSTACLE DETECTION

    Energy Technology Data Exchange (ETDEWEB)

    Maximillian J. Kieba

    2003-01-30

    This project develops a new and unique obstacle detection sensor for horizontal directional drilling (HDD) equipment. The development of this new technology will greatly improve the reliability and safety of natural gas HDD construction practices. This sensor utilizes a differential soil impedance measurement technique that will be sensitive to the presence of plastic and ceramic, as well as metallic obstacles. The use of HDD equipment has risen significantly in the gas industry because HDD provides a much more cost-effective and less disruptive method for gas pipe installation than older, trenching methods. However, there have been isolated strikes of underground utilities by HDD equipment, which may have been avoided if methods were available to detect other underground obstacles when using HDD systems. GTI advisors from the gas industry have ranked the value of solving the obstacle detection problem as the most important research and development project for GTI to pursue using Federal Energy Regulatory Commission (FERC) funds available through its industry partner, GRI. GTI proposes to develop a prototype down-hole sensor system that is simple and compact. The sensor utilizes an impedance measurement technique that is sensitive to the presence of metallic or nonmetallic objects in the proximity of the HDD head. The system will use a thin film sensor conformal with the drill head. The impedance of the soil will be measured with a low frequency signal injected through the drill head itself. A pair of bridge type impedance sensors, mounted orthogonal to one another, is capacitively coupled to the soil. Inclusions in the soil will cause changes to the sensor balance distinguishable from homogeneous soil. The sensor will provide range and direction data for obstacles near the HDD head. The goal is to provide a simple, robust system that provides the information required to avoid obstacles. This must be done within the size and ruggedness constraints of the HDD

  6. DIFFERENTIAL SOIL IMPEDANCE OBSTACLE DETECTION

    Energy Technology Data Exchange (ETDEWEB)

    Maximillian J. Kieba; Christopher J. Ziolkowski

    2004-10-29

    This project develops a new and unique obstacle detection sensor for horizontal directional drilling (HDD) equipment. The development of this new technology will greatly improve the reliability and safety of natural gas HDD construction practices. This sensor utilizes a differential soil impedance measurement technique that will be sensitive to the presence of plastic and ceramic, as well as metallic obstacles. The use of HDD equipment has risen significantly in the gas industry because HDD provides a much more cost-effective and less disruptive method for gas pipe installation than older, trenching methods. However, there have been isolated strikes of underground utilities by HDD equipment, which may have been avoided if methods were available to detect other underground obstacles when using HDD systems. GTI advisors from the gas industry have ranked the value of solving the obstacle detection problem as the most important research and development project for GTI to pursue using Federal Energy Regulatory Commission (FERC) funds available through its industry partner, GRI. GTI proposes to develop a prototype down-hole sensor system that is simple and compact. The sensor utilizes an impedance measurement technique that is sensitive to the presence of metallic or non-metallic objects in the proximity of the HDD head. The system will use a simple sensor incorporated into the drill head. The impedance of the soil will be measured with a low frequency signal injected through the drill head itself. A pair of bridge type impedance sensors, mounted orthogonal to one another, is coupled to the soil. Inclusions in the soil will cause changes to the sensor balance distinguishable from homogeneous soil. The sensor will provide range and direction data for obstacles near the HDD head. The goal is to provide a simple, robust system that provides the information required to avoid obstacles. This must be done within the size and ruggedness constraints of the HDD equipment. Imaging

  7. DIFFERENTIAL SOIL IMPEDANCE OBSTACLE DETECTION

    Energy Technology Data Exchange (ETDEWEB)

    Maximillian J. Kieba

    2002-08-30

    This project develops a new and unique obstacle detection sensor for horizontal directional drilling (HDD) equipment. The development of this new technology will greatly improve the reliability and safety of natural gas HDD construction practices. This sensor utilizes a differential soil impedance measurement technique that will be sensitive to the presence of plastic and ceramic, as well as metallic obstacles. The use of HDD equipment has risen significantly in the gas industry because HDD provides a much more cost-effective and less disruptive method for gas pipe installation than older, trenching methods. However, there have been isolated strikes of underground utilities by HDD equipment, which may have been avoided if methods were available to detect other underground obstacles when using HDD systems. GTI advisors from the gas industry have ranked the value of solving the obstacle detection problem as the most important research and development project for GTI to pursue using Federal Energy Regulatory Commission (FERC) funds available through its industry partner, GRI. GTI proposes to develop a prototype down-hole sensor system that is simple and compact. The sensor utilizes an impedance measurement technique that is sensitive to the presence of metallic or nonmetallic objects in the proximity of the HDD head. The system will use a thin film sensor conformal with the drill head. The impedance of the soil will be measured with a low frequency signal injected through the drill head itself. A pair of bridge type impedance sensors, mounted orthogonal to one another, is capacitively coupled to the soil. Inclusions in the soil will cause changes to the sensor balance distinguishable from homogeneous soil. The sensor will provide range and direction data for obstacles near the HDD head. The goal is to provide a simple, robust system that provides the information required to avoid obstacles. This must be done within the size and ruggedness constraints of the HDD

  8. DIFFERENTIAL SOIL IMPEDANCE OBSTACLE DETECTION

    Energy Technology Data Exchange (ETDEWEB)

    Maximillian J. Kieba

    2004-02-01

    This project develops a new and unique obstacle detection sensor for horizontal directional drilling (HDD) equipment. The development of this new technology will greatly improve the reliability and safety of natural gas HDD construction practices. This sensor utilizes a differential soil impedance measurement technique that will be sensitive to the presence of plastic and ceramic, as well as metallic obstacles. The use of HDD equipment has risen significantly in the gas industry because HDD provides a much more cost-effective and less disruptive method for gas pipe installation than older, trenching methods. However, there have been isolated strikes of underground utilities by HDD equipment, which may have been avoided if methods were available to detect other underground obstacles when using HDD systems. GTI advisors from the gas industry have ranked the value of solving the obstacle detection problem as the most important research and development project for GTI to pursue using Federal Energy Regulatory Commission (FERC) funds available through its industry partner, GRI. GTI proposes to develop a prototype down-hole sensor system that is simple and compact. The sensor utilizes an impedance measurement technique that is sensitive to the presence of metallic or nonmetallic objects in the proximity of the HDD head. The system will use a simple sensor incorporated into the drill head. The impedance of the soil will be measured with a low frequency signal injected through the drill head itself. A pair of bridge type impedance sensors, mounted orthogonal to one another, is coupled to the soil. Inclusions in the soil will cause changes to the sensor balance distinguishable from homogeneous soil. The sensor will provide range and direction data for obstacles near the HDD head. The goal is to provide a simple, robust system that provides the information required to avoid obstacles. This must be done within the size and ruggedness constraints of the HDD equipment. Imaging

  9. DIFFERENTIAL SOIL IMPEDANCE OBSTACLE DETECTION

    Energy Technology Data Exchange (ETDEWEB)

    Maximillian J. Kieba

    2002-11-27

    This project develops a new and unique obstacle detection sensor for horizontal directional drilling (HDD) equipment. The development of this new technology will greatly improve the reliability and safety of natural gas HDD construction practices. This sensor utilizes a differential soil impedance measurement technique that will be sensitive to the presence of plastic and ceramic, as well as metallic obstacles. The use of HDD equipment has risen significantly in the gas industry because HDD provides a much more cost-effective and less disruptive method for gas pipe installation than older, trenching methods. However, there have been isolated strikes of underground utilities by HDD equipment, which may have been avoided if methods were available to detect other underground obstacles when using HDD systems. GTI advisors from the gas industry have ranked the value of solving the obstacle detection problem as the most important research and development project for GTI to pursue using Federal Energy Regulatory Commission (FERC) funds available through its industry partner, GRI. GTI proposes to develop a prototype down-hole sensor system that is simple and compact. The sensor utilizes an impedance measurement technique that is sensitive to the presence of metallic or nonmetallic objects in the proximity of the HDD head. The system will use a thin film sensor conformal with the drill head. The impedance of the soil will be measured with a low frequency signal injected through the drill head itself. A pair of bridge type impedance sensors, mounted orthogonal to one another, is capacitively coupled to the soil. Inclusions in the soil will cause changes to the sensor balance distinguishable from homogeneous soil. The sensor will provide range and direction data for obstacles near the HDD head. The goal is to provide a simple, robust system that provides the information required to avoid obstacles. This must be done within the size and ruggedness constraints of the HDD

  10. DIFFERENTIAL SOIL IMPEDANCE OBSTACLE DETECTION

    Energy Technology Data Exchange (ETDEWEB)

    Maximillian J. Kieba

    2004-05-03

    This project develops a new and unique obstacle detection sensor for horizontal directional drilling (HDD) equipment. The development of this new technology will greatly improve the reliability and safety of natural gas HDD construction practices. This sensor utilizes a differential soil impedance measurement technique that will be sensitive to the presence of plastic and ceramic, as well as metallic obstacles. The use of HDD equipment has risen significantly in the gas industry because HDD provides a much more cost-effective and less disruptive method for gas pipe installation than older, trenching methods. However, there have been isolated strikes of underground utilities by HDD equipment, which may have been avoided if methods were available to detect other underground obstacles when using HDD systems. GTI advisors from the gas industry have ranked the value of solving the obstacle detection problem as the most important research and development project for GTI to pursue using Federal Energy Regulatory Commission (FERC) funds available through its industry partner, GRI. GTI proposes to develop a prototype down-hole sensor system that is simple and compact. The sensor utilizes an impedance measurement technique that is sensitive to the presence of metallic or nonmetallic objects in the proximity of the HDD head. The system will use a simple sensor incorporated into the drill head. The impedance of the soil will be measured with a low frequency signal injected through the drill head itself. A pair of bridge type impedance sensors, mounted orthogonal to one another, is coupled to the soil. Inclusions in the soil will cause changes to the sensor balance distinguishable from homogeneous soil. The sensor will provide range and direction data for obstacles near the HDD head. The goal is to provide a simple, robust system that provides the information required to avoid obstacles. This must be done within the size and ruggedness constraints of the HDD equipment. Imaging

  11. 基于等效负载阻抗扰动的分布式MPPT方法研究%A distributed maximum power point tracking method based on the equivalent load impedance disturbance

    Institute of Scientific and Technical Information of China (English)

    黄建明; 吴春华; 徐坤; 付立

    2012-01-01

    The operation principle of photovoltaic optimizer system and the essence of maximum power point tracking (MPPT) are introduced. Each PV module adopts MPPT control algorithm in photovoltaic optimizer system, which leads to wrong judgment of the traditional MPPT method due to the load impedance perturbation. Based on the equivalent load impedance perturbation, the distributed maximum power point tracking (DMPPT) is proposed to solve the problem. Considering the disturbance of control variables and load impedance to track MPP, the interaction between individual modules in the photovoltaic optimizer system is avoided. Finally, comparative experiments prove that the DMPPT method based on the equivalent load impedance perturbation proposed in this paper has the advantage of quick response and perturbation resistance to load impedance. Furthermore, the stability of this method is better than conventional MPPT method.%介绍了光伏优化器系统的工作原理及最大功率点跟踪的本质.针对光伏优化器系统中每块光伏组件进行MPPT控制,造成传统MPPT方法由于负载阻抗扰动而引起误判断的问题,提出了一种基于等效负载阻抗扰动的分布式最大功率点跟踪方法.该方法综合考虑控制量扰动和负载阻抗扰动进行MPPT判断,避免光伏优化器系统中各个独立模块之间的相互影响.通过对比实验证明提出的基于等效负载阻抗扰动的最大功率点跟踪方法具有快速的响应能力及抗负载阻抗扰动能力,其稳定性优于传统的MPPT方法.

  12. Biogenic metallic nanoparticles as catalyst for bioelectricity production: A novel approach in microbial fuel cells

    Energy Technology Data Exchange (ETDEWEB)

    Saravanakumar, Kandasamy, E-mail: saravana732@gmail.com [School of Agriculture and Biology, Shanghai Jiao Tong University, Shanghai (China); State Key Laboratory of Microbial Metabolism, Shanghai Jiao Tong University, Shanghai (China); Key Laboratory of Urban Agriculture (South), Ministry of Agriculture, Shanghai (China); MubarakAli, Davoodbasha [Microbial Genetic Engineering Laboratory, Division of Bioengineering, College of Life Science and Bioengineering, Incheon National University, Songdo 406772, Incheon (Korea, Republic of); Department of Microbiology, School of Lifesciences, Bharathidasan University, Tiruchirappalli 620024 (India); Kathiresan, Kandasamy [Centre of Advanced Study in Marine Biology, Faculty of Marine Sciences, Annamalai University, Parangipettai 608 502, Tamil Nadu (India); Thajuddin, Nooruddin [Department of Microbiology, School of Lifesciences, Bharathidasan University, Tiruchirappalli 620024 (India); Department of Botany and Microbiology, College of Science, King Saud University, Riyadh 11451 (Saudi Arabia); Alharbi, Naiyf S. [Department of Botany and Microbiology, College of Science, King Saud University, Riyadh 11451 (Saudi Arabia); Chen, Jie, E-mail: jiechen59@sjtu.edu.cn [School of Agriculture and Biology, Shanghai Jiao Tong University, Shanghai (China); State Key Laboratory of Microbial Metabolism, Shanghai Jiao Tong University, Shanghai (China); Key Laboratory of Urban Agriculture (South), Ministry of Agriculture, Shanghai (China)

    2016-01-15

    Highlights: • Trichoderma sp., showed an abilities to synthesis of AgNPs and AuNPs with an excellent stability. • AuNPs significantly enhanced the bioelectricity production by MFC of anaerobic fermentation as catalyst. • Maximum bioelectricity production was optimized and obtained the voltage of 432.80 mA using RSM. - Abstract: The present work aimed to use the biogenic metallic nanoparticles as catalyst for bioelectricity production in microbial fuel cell (MFC) approach under anaerobic condition. Silver and gold nanoparticles (AuNPs) were synthesized using Trichoderma sp. Particle size and cystallinity were measured by X-ray diffraction revealed the crystalline structure with average size of 36.17 nm. Electron microscopic studies showed spherical shaped silver nanoparticles (AgNPs) and cubical shaped AuNPs with size ranges from 50 to 150 nm. The concentration of biogenic metallic nanoparticles as catalyst for enhanced bioelectricity generations and estimated by response surface methodology (RSM) and found at the greatest of 342.80 mA under optimized conditions are time interval, temperature, nanoparticles used as 63 h, 28 ± 2.0 °C, 22.54 mg l{sup −1} (AgNPs) and 25.62 mg l{sup −1} (AuNPs) in a batch reactor. AuNPs acted as an excellent catalyst to enhance the bioelectricity production. This novel technique could be used for eco-friendly, economically feasible and facile electricity production.

  13. Tensor Impedance Surfaces

    Science.gov (United States)

    2010-11-30

    ELECTROMAGNEETIC SURFACE IMPEDANCE PROPERTIES FA9550-09-C-0198 DR. ADOUR KABAKIAN HUGHES RESEARCH LABS AFOSR / RSE 875 North Randolph Street, Suit...325 Room 3112 Arlington, Virginia 22203-1768 AFOSR / RSE AFRL-OSR-VA-TR-2012-0770 Distribution A We have investigated and determined how the tensor...the case of a TM wave, which favors propagation along the shorter principal axis. Standard terms apply U U U UU Arje Nachman RSE (Program Manager

  14. Impeded Dark Matter

    OpenAIRE

    Kopp, Joachim; Liu, Jia; Slatyer, Tracy R.; Wang, Xiao-Ping; Xue, Wei

    2016-01-01

    We consider a new class of thermal dark matter models, dubbed "Impeded Dark Matter", in which the mass splitting between the dark matter particles and their annihilation products is tiny. Compared to the previously proposed Forbidden Dark Matter scenario, the mass splittings we consider are much smaller, and are allowed to be either positive or negative. We demonstrate that either case can be easily realized without requiring tuning of model parameters. For negative mass splitting, we demonst...

  15. Examination of the bioelectrical activity of the masticatory muscles during Angle’s Class II division 2 therapy with an activator

    Directory of Open Access Journals (Sweden)

    Petrović Đorđe

    2014-01-01

    Full Text Available Background/Aim. The muscles of the orofacial region have great influence on the development of dentition and occlusion formation. It is known that improper function of these muscles is one of the major etiological factors in malocclusion. A correlation between function disorders of orofacial muscle and occlusion disorders has been confirmed, as well as a correlation between the bioelectric activity of the masticatory muscles, recorded by electromyography, and bite force upon maximal voluntary contraction of these muscles. The aim of the study was to analyze the bioelectriacal activity of temporal and masseter muscles. Methods. The sample consisted of 100 subjects of both sexes, divided into the control group (n = 30 with neutral and complete dental arches, and the study group (n = 70 of patients with distal occlusion. Electromyographic measurement of bioelectric potentials in all the subjects was conducted for the examined muscles in the physiologic rest position, central mandible occlusion, and during maximal voluntary contraction of muscles and saliva swallowing, in Angle Class I and II/2 occlusal relation-ships, prior to treatment, after one year of the orthodontic treatment and after the treatment with an activator. Results. Comparing the values of thebioelectrical activity in the control and the study group before the treatment, a decreased muscle activity was established in all the three positions in the study group. After the first year of orthodontic treatment the results showed an elevation in the bioelectrical activity in both muscles. After treatment with an activator, the bioelectrical activity in both muscles in the study group was higher than before the treatment, as it is confirmed by a positive highly significant coefficient of correlation. Conclusion. In all the three measured positions of the mandible with Angle Class II/2 malocclusion, bioelectrical activity was lowest at baseline and increased during the first year of

  16. Esophageal impedance baseline according to different time intervals

    Directory of Open Access Journals (Sweden)

    Ummarino Dario

    2012-06-01

    Full Text Available Abstract Background The impedance baseline has been shown to reflect esophageal integrity, and to be decreased in patients with esophagitis. However, different methods for the determination of the impedance baseline have not been compared. Methods The median impedance baseline was calculated in 10 consecutive multichannel intraluminal impedance recordings in children with non-erosive reflux disease. All children underwent an endoscopy with a biopsy as part of the clinical work-up to exclude esophagitis. The impedance baseline was obtained both by including and excluding all impedance episodes (IE; reflux, swallows and gas episodes during the full recording, and during the first 1-minute period without an IE every hour (method 1, every 2 hours (method 2 or every 4 hours (method 3. The impedance baseline obtained during the full recording was set at 100%, and the variation (difference in impedance baseline for the different methods and variability (difference in impedance baseline during one analysis period were assessed. Results None of the participants had esophagitis. The mean difference over the six channels between the impedance baseline over the total recording with and without IE was approximately 2.5%, and comparable for each channel (range 0.47% to 5.55%. A mean of 1,028 IEs were excluded in each tracing, and it took between 4 and 24 hours to delete all events in one tracing. The difference in the impedance baseline obtained with and without IEs was mainly caused by the gas episodes in the upper channels and swallows in the lower channels. The median impedance baseline according to the three one-minute analysis methods was comparable to the median impedance baseline according to the 24 hour analysis. Conclusions The automatic determination of the median impedance baseline over the total tracing including IEs is an adequate method. In isolated tracings with numerous IEs, the calculation of the median impedance baseline over one minute

  17. Evaluation of bioelectrical impedance analysis for identifying overweight individuals at increased cardiometabolic risk: a cross-sectional study

    National Research Council Canada - National Science Library

    Lamb, Maxine J E; Byrne, Christopher D; Wilson, James F; Wild, Sarah H

    2014-01-01

    ... characteristic curves. Odds ratios for increased cardiometabolic risk in body mass index categories associated with values above compared to below sex-specific percentage body fat thresholds with optimal diagnostic...

  18. Prediction of fat-free body mass from bioelectrical impedance and anthropometry among 3-year-old children using DXA

    DEFF Research Database (Denmark)

    Ejlerskov, Katrine Tschentscher; Jensen, Signe Marie; Christensen, Line B

    2014-01-01

    -validation approach. Prediction error of FFM was 3.0% for both equations (root mean square error: 360 and 356 g, respectively). The derived equations produced BIA-based prediction of FFM and FM near DXA scan results. We suggest that the predictive equations can be applied in similar population samples aged 2-4 years...

  19. [Effect of refeeding on the body composition of females with restrictive anorexia nervosa; anthropometry versus bioelectrical impedance].

    Science.gov (United States)

    de Mateo Silleras, Beatriz; Redondo del Río, Paz; Camina Martín, Alicia; Soto Célix, María; Alonso Torre, Sara R; Miján de la Torre, Alberto

    2013-01-01

    Objetivo: Evaluar la composición corporal en un grupo de pacientes desnutridas con anorexia nerviosa, respecto de controles sanas, antes y después del soporte nutricional, mediante antropometría y bioimpedancia. Métodos: Estudio observacional prospectivo. Se realizó una antropometría completa y un análisis de bioimpedancia a 12 mujeres con anorexia nerviosa restrictiva (24,5 años) al ingreso hospitalario y semanalmente durante la realimentación. El grupo control estuvo formado por 24 mujeres sanas (21 años). Se aplicaron los test t-Student, U-Mann-Whitney, t-Student para medidas repetidas o Wilcoxon. La concordancia entre antropometría y BIA se analizó mediante el coeficiente de correlación intraclase y Bland-Altman. Resultados: Las pacientes mejoraron significativamente todos los índices de composición corporal a lo largo de la estancia hospitalaria, aunque sus valores al alta siguieron siendo menores que los de las controles. La media de peso ganado fue 5,22 kg (DE: 1,42), de los que el 51,4% fueron masa grasa, con distribución central preferentemente. En las controles la ecuación de BIA que mejor concuerda con antropometría es la de Sun (CCI = 0,896); en las pacientes la concordancia fue más débil, al ingreso y al alta. Conclusiones: La realimentación produce una ganancia ponderal, fundamentalmente a expensas de masa grasa, con distribución central; no se consigue restablecer el estado nutricional. La concordancia entre antropometría y bioimpedancia para el estudio de la composición corporal es aceptable, especialmente en sujetos sanos. Se recomienda emplear antropometría, si no se dispone de BIA vectorial o algún método gold estandard para el análisis de la composición corporal, en casos de alteraciones importantes en la composición corporal y/o el balance hídrico.

  20. The novel application of artificial neural network on bioelectrical impedance analysis to assess the body composition in elderly

    National Research Council Canada - National Science Library

    Hsieh, Kuen-Chang; Chen, Yu-Jen; Lu, Hsueh-Kuan; Lee, Ling-Chun; Huang, Yong-Cheng; Chen, Yu-Yawn

    2013-01-01

    ...) of the elderly by using non-linear Back Propagation Artificial Neural Network (BP-ANN) model and to compare the predictive accuracy with the linear regression model by using energy dual X-ray absorptiometry (DXA...

  1. Observations involving broadband impedance modelling

    Energy Technology Data Exchange (ETDEWEB)

    Berg, J.S. [Stanford Linear Accelerator Center, Menlo Park, CA (United States)

    1996-08-01

    Results for single- and multi-bunch instabilities can be significantly affected by the precise model that is used for the broadband impedance. This paper discusses three aspects of broadband impedance modelling. The first is an observation of the effect that a seemingly minor change in an impedance model has on the single-bunch mode coupling threshold. The second is a successful attempt to construct a model for the high-frequency tails of an r.f. cavity. The last is a discussion of requirements for the mathematical form of an impedance which follow from the general properties of impedances. (author)

  2. Reciprocity and mutual impedance formulas within lossy cavities

    Directory of Open Access Journals (Sweden)

    F. Gronwald

    2005-01-01

    Full Text Available We discuss the validity of reciprocity and mutual impedance formulas within lossy cavities. Mutual impedance formulas are well-known from antenna theory and useful to describe the electromagnetic coupling between electromagnetic interference sources and victims. As an example the mutual impedance between two dipole antennas within a lossy rectangular cavity is calculated from a system of coupled Hallén's equations that efficiently is solved by the method of moments.

  3. Line Impedance Estimation Using Active and Reactive Power Variations

    DEFF Research Database (Denmark)

    Timbus, Adrian Vasile; Rodriguez, Pedro; Teodorescu, Remus;

    2007-01-01

    This paper proposes an estimation method of power system impedance based on power variations caused by a distributed power generation system (DPGS) at the point of common coupling (PCC). The proposed algorithm is computationally simple and uses the voltage variations at the point of common coupling...... (PCC) caused by the variations of the power delivered to utility network to derive the value of grid impedance. Accurate estimation of both resistive and inductive part of the impedance is obtained, as the results presented show....

  4. Wavelet analysis of the impedance cardiogram waveforms

    Science.gov (United States)

    Podtaev, S.; Stepanov, R.; Dumler, A.; Chugainov, S.; Tziberkin, K.

    2012-12-01

    Impedance cardiography has been used for diagnosing atrial and ventricular dysfunctions, valve disorders, aortic stenosis, and vascular diseases. Almost all the applications of impedance cardiography require determination of some of the characteristic points of the ICG waveform. The ICG waveform has a set of characteristic points known as A, B, E ((dZ/dt)max) X, Y, O and Z. These points are related to distinct physiological events in the cardiac cycle. Objective of this work is an approbation of a new method of processing and interpretation of the impedance cardiogram waveforms using wavelet analysis. A method of computer thoracic tetrapolar polyrheocardiography is used for hemodynamic registrations. Use of original wavelet differentiation algorithm allows combining filtration and calculation of the derivatives of rheocardiogram. The proposed approach can be used in clinical practice for early diagnostics of cardiovascular system remodelling in the course of different pathologies.

  5. Results from a Novel Method for Corrosion Studies of Electroplated Lithium Metal Based on Measurements with an Impedance Scanning Electrochemical Quartz Crystal Microbalance

    Directory of Open Access Journals (Sweden)

    Martin Winter

    2013-07-01

    Full Text Available A new approach to study the chemical stability of electrodeposited lithium on a copper metal substrate via measurements with a fast impedance scanning electrochemical quartz crystal microbalance is presented. The corrosion of electrochemically deposited lithium was compared in two different electrolytes, based on lithium difluoro(oxalato borate (LiDFOB and lithium hexafluorophosphate, both salts being dissolved in solvent blends of ethylene carbonate and diethyl carbonate. For a better understanding of the corrosion mechanisms, scanning electron microscopy images of electrodeposited lithium were also consulted. The results of the EQCM experiments were supported by AC impedance measurements and clearly showed two different corrosion mechanisms caused by the different salts and the formed SEIs. The observed mass decrease of the quartz sensor of the LiDFOB-based electrolyte is not smooth, but rather composed of a series of abrupt mass fluctuations in contrast to that of the lithium hexafluorophosphate-based electrolyte. After each slow decrease of mass a rather fast increase of mass is observed several times. The slow mass decrease can be attributed to a consolidation process of the SEI or to the partial dissolution of the SEI leaving finally lithium metal unprotected so that a fast film formation sets in entailing the observed fast mass increases.

  6. Modified Blumlein pulse-forming networks for bioelectrical applications.

    Science.gov (United States)

    Romeo, Stefania; Sarti, Maurizio; Scarfì, Maria Rosaria; Zeni, Luigi

    2010-07-01

    Intense nanosecond pulsed electric fields (nsPEFs) have been shown to induce, on intracellular structures, interesting effects dependent on electrical exposure conditions (pulse length and amplitude, repetition frequency and number of pulses), which are known in the literature as "bioelectrical effects" (Schoenbach et al., IEEE Trans Plasma Sci 30:293-300, 2002). In particular, pulses with a shorter width than the plasma membrane charging time constant (about 100 ns for mammalian cells) can penetrate the cell and trigger effects such as permeabilization of intracellular membranes, release of Ca(2+) and apoptosis induction. Moreover, the observed effects have led to exploration of medical applications, like the treatment of melanoma tumors (Nuccitelli et al., Biochem Biophys Res Commun 343:351-360, 2006). Pulsed electric fields allowing such effects usually range from several tens to a few hundred nanoseconds in duration and from a few to several tens of megavolts per meter in amplitude (Schoenbach et al., IEEE Trans Diel Elec Insul 14:1088-1109, 2007); however, the biological effects of subnanosecond pulses have been also investigated (Schoenbach et al., IEEE Trans Plasma Sci 36:414-422, 2008). The use of such a large variety of pulse parameters suggests that highly flexible pulse-generating systems, able to deliver wide ranges of pulse durations and amplitudes, are strongly required in order to explore effects and applications related to different exposure conditions. The Blumlein pulse-forming network is an often-employed circuit topology for the generation of high-voltage electric pulses with fixed pulse duration. An innovative modification to the Blumlein circuit has been recently devised which allows generation of pulses with variable amplitude, duration and polarity. Two different modified Blumlein pulse-generating systems are presented in this article, the first based on a coaxial cable configuration, matching microscopic slides as a pulse-delivery system

  7. Research on the Sealing Method for Measurement of Sound Transmission Loss in the Impedance Tube%阻抗管法隔声量测试试样密封方法探究

    Institute of Scientific and Technical Information of China (English)

    郑子迎; 车汉生; 吴源伟

    2014-01-01

    The sealing method of samples is an important factor affecting the measurement results in the measurement of sound transmission loss in the impedance tube. This paper introduces the test method and focuses on the specimen installation and sealing method in the impedance tube. By comparing 4 kinds of sealing methods, the performances of these methods are sorted. It provides reference for measurement of the sound transmission loss.%阻抗管法法向入射隔声量测试过程中,试样与阻抗管间的密封方式是测量结果的一个重要的影响因素。介绍了阻抗管测量法向入射隔声量的方法,重点介绍在阻抗管中的试样安装和密封方法,通过实施4种不同的密封方法,得出密封效果的排序,对阻抗法测量隔声量的试验实施具有参考价值。

  8. Sound radiation contrast in MR phase images. Method for the representation of elasticity, sound damping, and sound impedance changes; Schallstrahlungskontrast in MR-Phasenbildern. Methode zur Darstellung von Elastizitaets-, Schalldaempfungs- und Schallimpedanzaenderungen

    Energy Technology Data Exchange (ETDEWEB)

    Radicke, Marcus

    2009-12-18

    The method presented in this thesis combines ultrasound techniques with the magnetic-resonance tomography (MRT). An ultrasonic wave generates in absorbing media a static force in sound-propagation direction. The force leads at sound intensities of some W/cm{sup 2} and a sound frequency in the lower MHz range to a tissue shift in the micrometer range. This tissue shift depends on the sound power, the sound frequency, the sound absorption, and the elastic properties of the tissue. A MRT sequence of the Siemens Healthcare AG was modified so that it measures (indirectly) the tissue shift, codes as grey values, and presents as 2D picture. By means of the grey values the sound-beam slope in the tissue can be visualized, and so additionally sound obstacles (changes of the sound impedance) can be detected. By the MRT images token up spatial changes of the tissue parameters sound absorption and elasticity can be detected. In this thesis measurements are presented, which show the feasibility and future chances of this method especially for the mammary-cancer diagnostics. [German] Die in dieser Arbeit praesentierte Methode kombiniert Ultraschalltechniken mit der Magnetresonanztomographie (MRT). Eine Ultraschallwelle ruft in absorbierenden Medien eine statische Kraft in Schallausbreitungsrichtung hervor. Die Kraft fuehrt bei Schallintensitaeten von einigen W/cm{sup 2} und einer Schallfrequenz im niederen MHz-Bereich zu einer Gewebeverschiebung im Mikrometerbereich. Diese Gewebeverschiebung haengt ab von der Schallleistung, der Schallfrequenz, der Schallabsorption und den elastischen Eigenschaften des Gewebes. Es wurde eine MRT-Sequenz der Siemens Healthcare AG modifiziert, so dass sie (indirekt) die Gewebeverschiebung misst, als Grauwerte kodiert und als 2D-Bild darstellt. Anhand der Grauwerte kann der Schallstrahlverlauf in dem Gewebe visualisiert werden, und so koennen zusaetzlich Schallhindernisse (Aenderungen der Schallkennimpedanz) aufgespuert werden. Mit den

  9. Impedance group summary

    Science.gov (United States)

    Blaskiewicz, M.; Dooling, J.; Dyachkov, M.; Fedotov, A.; Gluckstern, R.; Hahn, H.; Huang, H.; Kurennoy, S.; Linnecar, T.; Shaposhnikova, E.; Stupakov, G.; Toyama, T.; Wang, J. G.; Weng, W. T.; Zhang, S. Y.; Zotter, B.

    1999-12-01

    The impedance working group was charged to reply to the following 8 questions relevant to the design of high-intensity proton machines such as the SNS or the FNAL driver. These questions were first discussed one by one in the whole group, then each ne of them assigned to one member to summarize. On the lst morning these contributions were publicly read, re-discussed and re-written where required—hence they are not the opinion of a particular person, but rather the averaged opinion of all members of the working group. (AIP)

  10. Study on electrical impedance matching for broadband ultrasonic transducer

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Geon Woo [University of Science and Technology, Daejeon (Korea, Republic of); Kim, Ki Bok [Korea Research Institute of Standards and Science, Center for Safety Measurement, Daejeon (Korea, Republic of); Baek, Kwang Sae [Elache Co., Busan (Korea, Republic of)

    2017-02-15

    Ultrasonic transducers with high resolution and resonant frequency are required to detect small defects (less than hundreds of μm) by ultrasonic testing. The resonance frequency and resolution of an ultrasonic transducer are closely related to the thickness of piezo-electric materials, backing materials, and the electric impedance matching technique. Among these factors, electrical impedance matching plays an important role because it can reduce the loss and reflection of ultrasonic energy differences in electrical impedance between an ultrasonic transducer and an ultrasonic defects detecting system. An LC matching circuit is the most frequently used electric matching method. It is necessary for the electrical impedance of an ultrasonic transducer to correspond to approximately 50 Ω to compensate the difference in electrical impedance between both connections. In this study, a 15 MHz immersion ultrasonic transducer was fabricated and an LC electrical impedance circuit was applied to that for having broad-band frequency characteristic.

  11. Beam measurements of the LHC impedance and validation of the impedance model

    CERN Document Server

    Esteban Müller, J F; Bohl, T; Mounet, N; Shaposhnikova, E; Timko, H

    2014-01-01

    Different measurements of the longitudinal impedance of the LHC done with single bunches with various intensities and longitudinal emittances during measurement sessions in 2011-2012 are compared with particle simulations based on the existing LHC impedance model. The very low reactive impedance of the LHC, with Im Z=n = 0.08, is not easy to measure. The most sensitive observation is the loss of Landau damping, which shows at which energy bunches become unstable depending on their parameters. In addition, the synchrotron frequency shift due to the reactive impedance was estimated following two methods. Firstly, it was obtained from the peak-detected Schottky spectrum. Secondly, a sine modulation in the RF phase was applied to the bunches of different intensities and the modulation frequency was scanned. In both cases, the synchrotron frequency shift was of the order of the measurement precision.

  12. Dynamic electrochemical impedance spectroscopy reconstructed from continuous impedance measurement of single frequency during charging/discharging

    Science.gov (United States)

    Huang, Jun; Li, Zhe; Zhang, Jianbo

    2015-01-01

    In this study, a novel implementation of dynamic electrochemical impedance spectroscopy (DEIS) is proposed. The method first measures the impedance continuously at a single frequency during one charging/discharging cycle, then repeats the measurement at a number of other selected frequencies. The impedance spectrum at a specific SOC is obtained by interpolating and collecting the impedance at all of the selected frequencies. The charge transfer resistance, Rct, from the DEIS is smaller than that from the steady EIS in a wide state-of-charge (SOC) range from 0.4 to 1.0, the Rct during charging is generally smaller than that during discharging for the battery chemistry used in this study.

  13. Lorentz Force Electrical Impedance Tomography

    CERN Document Server

    Grasland-Mongrain, Pol; Chapelon, Jean-Yves; Lafon, Cyril

    2014-01-01

    This article describes a method called Lorentz Force Electrical Impedance Tomography. The electrical conductivity of biological tissues can be measured through their sonication in a magnetic field: the vibration of the tissues inside the field induces an electrical current by Lorentz force. This current, detected by electrodes placed around the sample, is proportional to the ultrasonic pressure, to the strength of the magnetic field and to the electrical conductivity gradient along the acoustic axis. By focusing at different places inside the sample, a map of the electrical conductivity gradient can be established. In this study experiments were conducted on a gelatin phantom and on a beef sample, successively placed in a 300 mT magnetic field and sonicated with an ultrasonic transducer focused at 21 cm emitting 500 kHz bursts. Although all interfaces are not visible, in this exploratory study a good correlation is observed between the electrical conductivity image and the ultrasonic image. This method offers...

  14. Integrative assessment of kick boxers’ brain blood circulation and bio-electrical activity in conditions of correction technologies’ application

    Directory of Open Access Journals (Sweden)

    Romanov Y.N.

    2016-06-01

    Full Text Available Purpose: to scientifically substantiate the role of para-vertebral impacts on blood circulation and bio-electrical activity of kick boxers’ cortex. Material: in the research participated kick boxers (main group, n=62 and university students (control group, n=25 of 18-23 years’ age. Assessment of para-vertebral impacts with device Armos and classic massage was fulfilled with the help of the following methodic: trans-cranial dopplerography of head main arteries and cortex EEG of the tested. Results: it was found that with the help of para-vertebral impacts by device Armos linear velocity of cerebral blood flow reduces to normal limits and in- and inter-hemispheres’ interaction strength increases. Conclusions: para-vertebral impacts by device Armos activate integrative processes and inter-hemispheres’ interactions of different cortex areas of kick boxers. It can witness about better formation of functional systems, ensuring sports efficiency.

  15. Resonant impedance of bellows above cutoff

    Energy Technology Data Exchange (ETDEWEB)

    Krinsky, S

    1980-01-01

    The perturbation method of Chatard-Moulin and Papiernik is used to calculate the longitudinal and transverse impedances, Z(..omega..) and Z/sub perpendicular/(..omega..), of a bellows. The bellows shape is defined by its radius a(z) = a (1 + epsilons(z)), where a is the mean radius, epsilon a small parameter, and s(z) describes the convolution of the bellows. A finite wall conductivity is considered and the resonant contribution to the impedance above the cutoff frequency of the unperturbed chamber is determined, obtaining analytic approximations to the resonant frequencies, quality factors, and shunt impedances. The relation Z/sub perpendicular/(..omega..) = (2c/a/sup 2/)Z(..omega..)/..omega.., of course, does not hold as an identity, but it is found to be a useful relation for the shunt impedances, holding exactly for one family of transverse modes and providing an upper bound on the shunt impedances of the second set of transverse modes.

  16. Development of a field-portable small-size impedance analyzer for structural health monitoring using the electromechanical impedance technique

    Science.gov (United States)

    Giurgiutiu, Victor; Xu, Buli

    2004-07-01

    Electromechanical (E/M) impedance method is emerging as an effective and powerful technique for structural health monitoring. The E/M impedance method utilizes as its main apparatus an impedance analyzer that reads the in-situ E/M impedance of piezoelectric wafer active sensors (PWAS) attached to the monitored structure. Laboratory-type impedance analyzers (e.g. HP4194) are bulky, heavy, and expensive. They cannot be easily carried into the field for on-site structural health monitoring. To address this issue, means of to reduce the size of the impedance analyzer making the impedance analyzer more compact and field-portable are explored. In this paper, we present a systematic approach to the development of a field-portable small-size impedance analyzer for structural health monitoring using the electromechanical impedance technique. Our approach consists of several developmental stages. First, we perform a simulation of the E/M Impedance technique and develop the software tools for analyzing the signal in a fast and efficient way while maintaining the desired accuracy. The objective of this signal processing part is to obtain the complex impedance, ZR+iZI)=|Z| angle arg Z, at a number of frequencies in a predetermined range. Several signal processing methods were explored such as: (a) integration method; (b) correlation method; (c) Discrete Fourier transform (DFT) method. Second, we discuss the hardware issues associated with the implementation of this approach. The hardware system architecture consists of several blocks: (a) reference signal generation; (b) voltage and current measurements; and (c) digital signal acquisition and processing. Practical results obtained during proof-of-concept experiments are presented and comparatively examined.

  17. Outdoor ground impedance models.

    Science.gov (United States)

    Attenborough, Keith; Bashir, Imran; Taherzadeh, Shahram

    2011-05-01

    Many models for the acoustical properties of rigid-porous media require knowledge of parameter values that are not available for outdoor ground surfaces. The relationship used between tortuosity and porosity for stacked spheres results in five characteristic impedance models that require not more than two adjustable parameters. These models and hard-backed-layer versions are considered further through numerical fitting of 42 short range level difference spectra measured over various ground surfaces. For all but eight sites, slit-pore, phenomenological and variable porosity models yield lower fitting errors than those given by the widely used one-parameter semi-empirical model. Data for 12 of 26 grassland sites and for three beech wood sites are fitted better by hard-backed-layer models. Parameter values obtained by fitting slit-pore and phenomenological models to data for relatively low flow resistivity grounds, such as forest floors, porous asphalt, and gravel, are consistent with values that have been obtained non-acoustically. Three impedance models yield reasonable fits to a narrow band excess attenuation spectrum measured at short range over railway ballast but, if extended reaction is taken into account, the hard-backed-layer version of the slit-pore model gives the most reasonable parameter values.

  18. The determination of the phase transition temperatures of a semifluorinated liquid crystalline biphenyl ester by impedance spectroscopy as an alternative method

    Science.gov (United States)

    Yıldız, Alptekin; Canli, Nimet Yilmaz; Karanlık, Gürkan; Ocak, Hale; Okutan, Mustafa; Eran, Belkız Bilgin

    2016-12-01

    Dielectric spectroscopy (DS) is a very powerful and important for better understanding of the molecular dynamics and relaxation phenomena in liquid crystals. The dielectric and impedance characteristics Ethyl 4-(7,7,8,8,9,9,10,10,10-nonafluorodecyloxy)biphenyl-4‧-carboxylate (ENBC) liquid crystal have been analyzed over the frequency range of 100 Hz to MHz in the temperature region from room temperature to 180 °C. The compound ENBC shows enantiotropic a smectic mesophase in a wide temperature range. The phase transition temperatures T (°C) of the liquid crystal ENBC, which were characterized by Differential Scanning Calorimetry (DSC), have been verified by the dielectric measurements and conductivity mechanisms of the ENBC. The activation energies for some selected angular frequencies have also been calculated.

  19. The determination of the phase transition temperatures of a semifluorinated liquid crystalline biphenyl ester by impedance spectroscopy as an alternative method

    Energy Technology Data Exchange (ETDEWEB)

    Yıldız, Alptekin [Istanbul Technical University, Department of Physics Engineering, Maslak, 34469 Istanbul (Turkey); Yildiz Technical University, Department of Physics, 34220 Istanbul (Turkey); Canli, Nimet Yilmaz, E-mail: niyilmaz@yahoo.com [Yildiz Technical University, Department of Physics, 34220 Istanbul (Turkey); Karanlık, Gürkan; Ocak, Hale [Yildiz Technical University, Department of Chemistry, 34220 Istanbul (Turkey); Okutan, Mustafa [Yildiz Technical University, Department of Physics, 34220 Istanbul (Turkey); Eran, Belkız Bilgin [Yildiz Technical University, Department of Chemistry, 34220 Istanbul (Turkey)

    2016-12-15

    Dielectric spectroscopy (DS) is a very powerful and important for better understanding of the molecular dynamics and relaxation phenomena in liquid crystals. The dielectric and impedance characteristics Ethyl 4-(7,7,8,8,9,9,10,10,10-nonafluorodecyloxy)biphenyl-4′-carboxylate (ENBC) liquid crystal have been analyzed over the frequency range of 100 Hz to MHz in the temperature region from room temperature to 180 °C. The compound ENBC shows enantiotropic a smectic mesophase in a wide temperature range. The phase transition temperatures T (°C) of the liquid crystal ENBC, which were characterized by Differential Scanning Calorimetry (DSC), have been verified by the dielectric measurements and conductivity mechanisms of the ENBC. The activation energies for some selected angular frequencies have also been calculated.

  20. On coupling impedances of pumping holes

    Energy Technology Data Exchange (ETDEWEB)

    Kurennoy, S.

    1993-04-01

    Coupling impedances of a single small hole in vacuum-chamber walls have been calculated at low frequencies. To generalize these results for higher frequencies and/or larger holes one needs to solve coupled integral equations for the effective currents. These equations are solved for two specific hole shapes. The effects of many holes at high frequencies where the impedances are not additive are studied using a perturbation-theory method. The periodic versus random distributions of the pumping holes in the Superconducting Super Collider liner are compared.

  1. Impedance properties of circular microstrip antenna

    Science.gov (United States)

    Deshpande, M. D.; Bailey, M. C.

    1983-01-01

    A moment method solution to the input impedance of a circular microstrip antenna excited by either a microstrip feed or a coaxial probe is presented. Using the exact dyadic Green's function and the Fourier transform the problem is formulated in terms of Richmond's reaction integral equation from which the unknown patch current can be solved for. The patch current is expanded in terms of regular surface patch modes and an attachment mode (for probe excited case) which insures continuity of the current at probe/patch junction, proper polarization and p-dependance of patch current in the vicinity of the probe. The input impedance of a circular microstrip antenna is computed and compared with earlier results. Effect of attachment mode on the input impedance is also discussed.

  2. Impedance plethysmographic observations in thoracic outlet syndrome.

    Directory of Open Access Journals (Sweden)

    Nerurkar S

    1990-07-01

    Full Text Available Forty patients with symptoms of neuro-vascular compression in the upper extremities were subjected to impedance plethysmographic study using Parulkar′s method. Two patients recorded decreased blood flow (BFI in supine position and were diagnosed as having partial occlusion at subclavian level. Sixteen of the patients recorded decreased BFI on 90 degrees abduction and hyper-abduction. Twelve of these patients had radiological evidence of anomalous cervicle ribs. In remaining four patients extrinsic impression on the subclavian artery due to fibrous deposits was confirmed by arteriography. Remaining 22 patients recorded normal impedance plethysmograms. Impedance plethysmography thus provided a non-invasive modality for confirmation of vascular compression in thoracic outlet syndrome.

  3. Bench Measurements of Low Frequency Transverse Impedance

    CERN Document Server

    Caspers, Friedhelm; Mostacci, A

    2003-01-01

    For frequencies below 10 MHz the classical two wire transmission line method is subject to difficulties in sensitivity and measurement uncertainties. Thus for evaluation of the low frequency transverse impedance properties of the LHC dump kicker a modified version of the two wire transmission line has been used. It consists, in the present case, of a 10 turn loop of approximately 1 meter length and 2 cm width. The change of input impedance of the loop is measured as a function of the surroundings and by using a proper reference (metallic beampipe) these changes are converted into a meaningful transverse beam coupling impedance. Measurements of several calibration objects have shown close agreement with theoretical results.

  4. Comparison of two field methods for estimating body fat in different spanish dance disciplines.

    Science.gov (United States)

    Alvero-Cruz, José Ramón; Marfell-Jones, Mike; Alacid, Fernando; Artero Orta, Pedro; Correas-Gómez, Lorena; Santonja Medina, Fernando; Carnero, Elvis A

    2014-09-01

    The purpose of the present study was to investigate percentage body fat (%BF) differences in three Spanish dance disciplines and to compare skinfold and bioelectrical impedance predictions of body fat percentage in the same sample. Seventy-six female dancers, divided into three groups, Classical (n=23), Spanish (n=29) and Flamenco (n=24), were measured using skinfold measurements at four sites: triceps, subscapular, biceps and iliac crest, and whole body multi-frequency bioelectrical impedance (BIA). The skinfold measures were used to predict body fat percentage via Durnin and Womersley's and Segal, Sun and Yannakoulia equations by BIA. Differences in percent fat mass between groups (Classical, Spanish and Flamenco) were tested by using repeated measures analysis (ANOVA). Also, Pearson's product-moment correlations were performed on the body fat percentage values obtained using both methods. In addition, Bland-Altman plots were used to assess agreement, between anthropometric and BIA methods. Repeated measures analysis of variance did not found differences in %BF between modalities (p<0.05). Fat percentage correlations ranged from r= 0.57 to r=0.97 (all, p<0.001). Bland-Altman analysis revealed differences between BIA Yannakoulia as a reference method with BIA Segal (-0.35 ± 2.32%, 95%CI: -0.89to 0.18, p=0.38), with BIA Sun (-0.73 ± 2.3%, 95%CI: -1.27 to -0.20, p=0.014) and Durnin-Womersley (-2.65 ± 2,48%, 95%CI: -3.22 to -2.07, p<0.0001). It was concluded that body fat percentage estimates by BIA compared with skinfold method were systematically different in young adult female ballet dancers, having a tendency to produce underestimations as %BF increased with Segal and Durnin-Womersley equations compared to Yannakoulia, concluding that these methods are not interchangeable. Copyright AULA MEDICA EDICIONES 2014. Published by AULA MEDICA. All rights reserved.

  5. Comparison of two field methods for estimating body fat in different Spanish Dance disciplines

    Directory of Open Access Journals (Sweden)

    José Ramón Alvero-Cruz

    Full Text Available The purpose of the present study was to investigate percentage body fat (%BF differences in three Spanish dance disciplines and to compare skinfold and bioelectrical impedance predictions of body fat percentage in the same sample. Seventy-six female dancers, divided into three groups, Classical (n=23, Spanish (n=29 and Flamenco (n=24, were measured using skinfold measurements at four sites: triceps, subscapular, biceps and iliac crest, and whole body multi-frequency bioelectrical impedance (BIA. The skin-fold measures were used to predict body fat percentage via Durnin and Womersley's and Segal, Sun and Yannakoulia equations by BIA. Differences in percent fat mass between groups (Classical, Spanish and Flamenco were tested by using repeated measures analysis (ANOVA. Also, Pearson's product-moment correlations were performed on the body fat percentage values obtained using both methods. In addition, Bland-Altman plots were used to assess agreement, between anthropometric and BIA methods. Repeated measures analysis of variance did not found differences in %BF between modalities (p<0.05. Fat percentage correlations ranged from r= 0.57 to r=0.97 (all, p<0.001. Bland-Altman analysis revealed differences between BIA Yannakoulia as a reference method with BIA Segal (-0.35 ± 2.32%, 95%CI: -0.89to 0.18, p=0.38, with BIA Sun (-0.73 ± 2.3%, 95%CI: -1.27 to -0.20, p=0.014 and Durnin-Womersley (-2.65 ± 2,48%, 95%CI: -3.22 to -2.07, p<0.0001. It was concluded that body fat percentage estimates by BIA compared with skinfold method were systematically different in young adult female ballet dancers, having a tendency to produce underestimations as %BF increased with Segal and Durnin-Womersley equations compared to Yannakoulia, concluding that these methods are not interchangeable.

  6. Novel monitoring method for the management of heart failure: combined measurement of body weight and bioimpedance index of body fat percentage.

    Science.gov (United States)

    Kataoka, Hajime

    2009-11-01

    Although body weight scales are most commonly used to evaluate body fluid status during follow-up of definite heart failure (HF) patients, bioimpedance measurement methods have become increasingly available in the clinical setting. These monitoring methods, however, are typically used separately to evaluate body fluid status in HF patients. Kataoka developed a novel method for monitoring HF patients using a digital weight scale that incorporated a bioelectrical impedance analyzer. This method combines the well-known advantages of body weighing with a refined bioimpedance technique to monitor HF status and provides valid information regarding a change in a patient's body fluid status during follow-up for HF, such as predominant fluid versus fat weight gain or loss. This special report describes examples of the practical use of this method for monitoring and treating definite HF patients.

  7. A-Source Impedance Network

    DEFF Research Database (Denmark)

    Siwakoti, Yam Prasad; Blaabjerg, Frede; Galigekere, Veda Prakash;

    2016-01-01

    A novel A-source impedance network is proposed in this letter. The A-source impedance network uses an autotransformer for realizing converters for any application that demand a very high dc voltage gain. The network utilizes a minimal turns ratio compared to other Magnetically Coupled Impedance S...... with an example single-switch 400 W dc-dc converter. For the closed-loop control design and stability assessment, a small signal model and its analysis of the proposed network are also presented in brief.......A novel A-source impedance network is proposed in this letter. The A-source impedance network uses an autotransformer for realizing converters for any application that demand a very high dc voltage gain. The network utilizes a minimal turns ratio compared to other Magnetically Coupled Impedance...

  8. Application of dynamic impedance spectroscopy to atomic force microscopy

    Directory of Open Access Journals (Sweden)

    Kazimierz Darowicki, Artur Zieliński and Krzysztof J Kurzydłowski

    2008-01-01

    Full Text Available Atomic force microscopy (AFM is a universal imaging technique, while impedance spectroscopy is a fundamental method of determining the electrical properties of materials. It is useful to combine those techniques to obtain the spatial distribution of an impedance vector. This paper proposes a new combining approach utilizing multifrequency scanning and simultaneous AFM scanning of an investigated surface.

  9. Electrochemical impedance spectroscopy in solid state ionics: recent advances

    NARCIS (Netherlands)

    Boukamp, Bernard A.

    2004-01-01

    Electrochemical Impedance Spectroscopy (EIS) has become an important research tool in Solid State Ionics. Some new developments are highlighted: new methods of automatic parameter extraction from impedance measurements are briefly discussed. The Kramers–Kronig data validation test presents another p

  10. IMPEDANCE OF FINITE LENGTH RESISTOR

    Energy Technology Data Exchange (ETDEWEB)

    KRINSKY, S.; PODOBEDOV, B.; GLUCKSTERN, R.L.

    2005-05-15

    We determine the impedance of a cylindrical metal tube (resistor) of radius a, length g, and conductivity {sigma}, attached at each end to perfect conductors of semi-infinite length. Our main interest is in the asymptotic behavior of the impedance at high frequency, k >> 1/a. In the equilibrium regime, , the impedance per unit length is accurately described by the well-known result for an infinite length tube with conductivity {sigma}. In the transient regime, ka{sup 2} >> g, we derive analytic expressions for the impedance and wakefield.

  11. [Principles of design of neural-network analog-to-digital converters of bioelectric signals].

    Science.gov (United States)

    Loktiukhin, V N; Chelebaev, S V

    2007-01-01

    A design principle and a procedure for synthesis of neural-network analog-to-digital converters of bioelectric signals are suggested. An example of implementation of an FPGA-based neural-network converter for classification of bioparameters is presented.

  12. Regulation of cell behavior and tissue patterning by bioelectrical signals: challenges and opportunities for biomedical engineering.

    Science.gov (United States)

    Levin, Michael; Stevenson, Claire G

    2012-01-01

    Achieving control over cell behavior and pattern formation requires molecular-level understanding of regulatory mechanisms. Alongside transcriptional networks and biochemical gradients, there functions an important system of cellular communication and control: transmembrane voltage gradients (V(mem)). Bioelectrical signals encoded in spatiotemporal changes of V(mem) control cell proliferation, migration, and differentiation. Moreover, endogenous bioelectrical gradients serve as instructive cues mediating anatomical polarity and other organ-level aspects of morphogenesis. In the past decade, significant advances in molecular physiology have enabled the development of new genetic and biophysical tools for the investigation and functional manipulation of bioelectric cues. Recent data implicate V(mem) as a crucial epigenetic regulator of patterning events in embryogenesis, regeneration, and cancer. We review new conceptual and methodological developments in this fascinating field. Bioelectricity offers a novel way of quantitatively understanding regulation of growth and form in vivo, and it reveals tractable, powerful control points that will enable truly transformative applications in bioengineering, regenerative medicine, and synthetic biology.

  13. The Evaluation of Bioelectrical Activity of Pelvic Floor Muscles Depending on Probe Location: A Pilot Study

    Directory of Open Access Journals (Sweden)

    Tomasz Halski

    2013-01-01

    Full Text Available Objectives. The main objective was to determine how the depth of probe placement affects functional and resting bioelectrical activity of the PFM and whether the recorded signal might be dependent on the direction in which the probe is rotated. Participants. The study comprised of healthy, nulliparous women between the ages of 21 and 25. Outcome Measures. Bioelectric activity of the PFM was recorded from four locations of the vagina by surface EMG and vaginal probe. Results. There were no statistically significant differences between the results during functional sEMG activity. During resting sEMG activity, the highest bioelectrical activity of the PFM was observed in the L1 and the lowest in the L4 and a statistically significant difference between the highest and the lowest results of resting sEMG activity was observed (P=0.0043. Conclusion. Different electrodes placement during functional contraction of PFM does not affect the obtained results in sEMG evaluation. In order to diagnose the highest resting activity of PFM the recording plates should be placed toward the anterior vaginal wall and distally from the introitus. However, all of the PFM have similar bioelectrical activity and it seems that these muscles could be treated as a single muscle.

  14. Nutritional assessment methods for zinc supplementation in prepubertal non-zinc-deficient children

    Directory of Open Access Journals (Sweden)

    Márcia Marília Gomes Dantas Lopes

    2015-10-01

    Full Text Available Background: Zinc is an essential nutrient that is required for numerous metabolic functions, and zinc deficiency results in growth retardation, cell-mediated immune dysfunction, and cognitive impairment. Objective: This study evaluated nutritional assessment methods for zinc supplementation in prepubertal non-zinc-deficient children. Design: We performed a randomised, controlled, triple-blind study. The children were divided into a control group (10% sorbitol, n=31 and an experimental group (10 mg Zn/day, n=31 for 3 months. Anthropometric and dietary assessments as well as bioelectrical measurements were performed in all children. Results: Our study showed (1 an increased body mass index for age and an increased phase angle in the experimental group; (2 a positive correlation between nutritional assessment parameters in both groups; (3 increased soft tissue, and mainly fat-free mass, in the body composition of the experimental group, as determined using bioelectrical impedance vector analysis; (4 increased consumption of all nutrients, including zinc, in the experimental group; and (5 an increased serum zinc concentration in both groups (p<0.0001. Conclusions: Given that a reference for body composition analysis does not exist for intervention studies, longitudinal studies are needed to investigate vector migration during zinc supplementation. These results reinforce the importance of employing multiple techniques to assess the nutritional status of populations.

  15. Development of three-dimension microelectrode array for bioelectric measurement using the liquidmetal-micromolding technique

    Energy Technology Data Exchange (ETDEWEB)

    Liu, Ran, E-mail: liuran@tsinghua.edu.cn; Yang, Xueyao; Chen, Weixing [Department of Biomedical Engineering, School of Medicine, Tsinghua University, Beijing 100084 (China); Jin, Cuiyun; Fu, Jingjing [College of Information Science and Technology, Beijing University of Chemical Technology, Beijing 100029 (China); Liu, Jing [Department of Biomedical Engineering, School of Medicine, Tsinghua University, Beijing 100084 (China); Technical Institute of Physics and Chemistry, Chinese Academy of Sciences, Beijing 100190 (China)

    2013-11-04

    A method of manufacturing three-dimension microneedle electrode arrays is presented in this paper using the micromolding technology with liquid metal at room temperature, based on the physical property of the Bi-In-Sn liquid metal alloy, being its melting point especially low. Observed under scanning electron microscopy, the needle body of the electrode chip manufactured using this method has a good consistency. Skin penetration test in-vitro indicates that the microneedle electrode can pierce the stratum corneum and cross the high-impedance layer to acquire electrical signals. Electrical impedance and polarization voltage experimental results show that the electrode chips have great electric characteristics and meet the practical application demands.

  16. Analyzing Impedance Spectroscopy Results

    Institute of Scientific and Technical Information of China (English)

    Yoed Tsur; Sioma Baltianski

    2006-01-01

    In this contribution we briefly discuss several analysis techniques for impedance spectroscopy experiments. A number of different approaches, which differ even by the definition of the problem, are used in the literature. Some aimed towards finding an equivalent circuit. Others aimed towards finding directly dielectric properties of the material under an assumed model. Others towards finding distribution of relaxation times, either parametric or point-by point. No matter what the approach is, this will always be an ill-posed problem in the sense that there exist a large number of possible solutions that solve the problem (mathematically) equally well. Therefore some a-priori knowledge about the system must be used. In addition, we should remember that the ultimate goal is to get physical insight about the system.

  17. 利用机械阻抗求取机械系统传递函数的方法%A simple method of solving transfer function of mechanical system by mechanical impedance

    Institute of Scientific and Technical Information of China (English)

    王泽南

    2001-01-01

    A simple method of so lving transfer function of mechanical system by mechanical impedance is proposed ,which is similar to the method of complex impedance in electrical system. Three basic elements of mechanical system are fixed into complex domain elements as t he spring, and the calculus of differential equations is reduced. Differing from electrical system, the structural diagrams of mechanical system need the chang e of series combinations of mass elements into parallel combinations, which is v ery simple.%文章提出了一种利用机械阻抗求取机械系统传递 函数的简便方法,它类似于电系统中的复阻抗方法。这种方法将机械系统3种基本元件固化 为类似弹簧的复域元件,使求取系统传递函数免去列写微分方程的环节。与电系统稍有不同 的是,这种方法需将机械系统结构图作适当的改形。改形也很简单,只要将串联形式的质量 元件改为并联即可。

  18. One-Way Traffic Organization Optimization Method Based on Network Impedance and Traffic Efficiency%基于路网阻抗及交通效率的单向交通组织优化方法

    Institute of Scientific and Technical Information of China (English)

    张胜凯; 黄文娟; 韩高峰

    2012-01-01

    To improve the utilization of branch roads and reduce the traffic pressure on arterial roads, the optimization approach of one-way traffic organization is proposed from the view of reducing network impedance and improving traffic efficiency. The bievel programming model is developed with the objective of minimizing network impedance and travel time. The minimum objectixie value of the upper model is obtained by optimizing one-way traffic, and the lower one adopts the capacity limitation-incremental loading method to distribute traffic flow. Through establishing virtual road network, the effectiveness of one-way traffic organization is proved by comparing the network impedance and travel time before and after optimization.%为提高支路的利用率,以降低主干道的交通压力,从降低路网阻抗及提高交通效率的角度出发,提出单向交通组织的优化方法。建立以路网阻抗及出行时间最小化为目标的双层优化模型,其中上层模型通过优化支路的单向交通组织方案使得目标值达到最小,下层模型按照容量限制——增量加栽方法进行交通量的重分配。通过建立虚拟路网,类比分析单向交通组织优化前后的路网阻抗及出行时间,验证单向交通组织的优化效果。

  19. Electrical Impedance Spectroscopy for Detection of Cells in Suspensions Using Microfluidic Device with Integrated Microneedles

    National Research Council Canada - National Science Library

    Mansor, Muhammad; Takeuchi, Masaru; Nakajima, Masahiro; Hasegawa, Yasuhisa; Ahmad, Mohd

    2017-01-01

    .... The state of the art method for impedance flow cytometry detection utilizes an embedded electrode in the microfluidic to perform measurement of electrical impedance of the presence of cells at the sensing area...

  20. Development on electromagnetic impedance function modeling and its estimation

    Energy Technology Data Exchange (ETDEWEB)

    Sutarno, D., E-mail: Sutarno@fi.itb.ac.id [Earth Physics and Complex System Division Faculty of Mathematics and Natural Sciences Institut Teknologi Bandung (Indonesia)

    2015-09-30

    Today the Electromagnetic methods such as magnetotellurics (MT) and controlled sources audio MT (CSAMT) is used in a broad variety of applications. Its usefulness in poor seismic areas and its negligible environmental impact are integral parts of effective exploration at minimum cost. As explor